Huang, Yuan-sheng; Yang, Zhi-rong; Zhan, Si-yan
2015-06-18
To investigate the use of simple pooling and bivariate model in meta-analyses of diagnostic test accuracy (DTA) published in Chinese journals (January to November, 2014), compare the differences of results from these two models, and explore the impact of between-study variability of sensitivity and specificity on the differences. DTA meta-analyses were searched through Chinese Biomedical Literature Database (January to November, 2014). Details in models and data for fourfold table were extracted. Descriptive analysis was conducted to investigate the prevalence of the use of simple pooling method and bivariate model in the included literature. Data were re-analyzed with the two models respectively. Differences in the results were examined by Wilcoxon signed rank test. How the results differences were affected by between-study variability of sensitivity and specificity, expressed by I2, was explored. The 55 systematic reviews, containing 58 DTA meta-analyses, were included and 25 DTA meta-analyses were eligible for re-analysis. Simple pooling was used in 50 (90.9%) systematic reviews and bivariate model in 1 (1.8%). The remaining 4 (7.3%) articles used other models pooling sensitivity and specificity or pooled neither of them. Of the reviews simply pooling sensitivity and specificity, 41(82.0%) were at the risk of wrongly using Meta-disc software. The differences in medians of sensitivity and specificity between two models were both 0.011 (P<0.001, P=0.031 respectively). Greater differences could be found as I2 of sensitivity or specificity became larger, especially when I2>75%. Most DTA meta-analyses published in Chinese journals(January to November, 2014) combine the sensitivity and specificity by simple pooling. Meta-disc software can pool the sensitivity and specificity only through fixed-effect model, but a high proportion of authors think it can implement random-effect model. Simple pooling tends to underestimate the results compared with bivariate model. The greater the between-study variance is, the more likely the simple pooling has larger deviation. It is necessary to increase the knowledge level of statistical methods and software for meta-analyses of DTA data.
Jha, Ashwini Kumar; Tang, Wen Hao; Bai, Zhi Bin; Xiao, Jia Quan
2014-01-01
To perform a meta-analysis to review the sensitivity and specificity of computed tomography and different known computed yomography signs for the diagnosis of strangulation in patients with acute small bowel obstruction. A comprehensive Pubmed search was performed for all reports that evaluated the use of CT and discussed different CT criteria for the diagnosis of acute SBO. Articles published in English language from January 1978 to June 2008 were included. Review articles, case reports, pictorial essays and articles without original data were excluded. The bivariate random effect model was used to obtain pooled sensitivity and pooled specificity. Summary receiver operating curve was calculated using Meta-Disc. Software Openbugs 3.0.3 was used to summarize the data. A total of 12 studies fulfilled the inclusion criteria. The pooled sensitivity and specificity of CT in the diagnosis of strangulation was 0.720 (95% CI 0.674 to 0.763) and 0.866 (95% CI 0.837 to 0.892) respectively. Among different CT signs, mesenteric edema had highest Pooled sensitivity of 0. 741 and lack of bowel wall enhancement had highest pooled specificity of 0.991. This review demonstrates that CT is highly sensitive as well as specific in the preoperative diagnosis of strangulation SBO which are in accordance with the published studies. Our analysis also shows that "presence of mesenteric fluid" is most sensitive, and "lack of bowel wall enhancement" is most specific CT sign of strangulation, and also justifies need of large scale prospective studies to validate the results obtained as well as to determine a clinical protocol.
NASA Astrophysics Data System (ADS)
Williams, Christopher J.; Moffitt, Christine M.
2003-03-01
An important emerging issue in fisheries biology is the health of free-ranging populations of fish, particularly with respect to the prevalence of certain pathogens. For many years, pathologists focused on captive populations and interest was in the presence or absence of certain pathogens, so it was economically attractive to test pooled samples of fish. Recently, investigators have begun to study individual fish prevalence from pooled samples. Estimation of disease prevalence from pooled samples is straightforward when assay sensitivity and specificity are perfect, but this assumption is unrealistic. Here we illustrate the use of a Bayesian approach for estimating disease prevalence from pooled samples when sensitivity and specificity are not perfect. We also focus on diagnostic plots to monitor the convergence of the Gibbs-sampling-based Bayesian analysis. The methods are illustrated with a sample data set.
Bazot, Marc; Daraï, Emile
2017-12-01
The aim of the present review was to evaluate the contribution of clinical examination and imaging techniques, mainly transvaginal sonography and magnetic resonance imaging (MRI) to diagnose deep infiltrating (DE) locations using prisma statement recommendations. Clinical examination has a relative low sensitivity and specificity to diagnose DE. Independently of DE locations, for all transvaginal sonography techniques a pooled sensitivity and specificity of 79% and 94% are observed approaching criteria for a triage test. Whatever the protocol and MRI devices, the pooled sensitivity and specificity for pelvic endometriosis diagnosis were 94% and 77%, respectively. For rectosigmoid endometriosis, pooled sensitivity and specificity of MRI were 92% and 96%, respectively fulfilling criteria of replacement test. In conclusion, advances in imaging techniques offer high sensitivity and specificity to diagnose DE with at least triage value and for rectosigmoid endometriosis replacement value imposing a revision of the concept of laparoscopy as the gold standard. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Corstjens, Paul L A M; Hoekstra, Pytsje T; de Dood, Claudia J; van Dam, Govert J
2017-11-01
Methodological applications of the high sensitivity genus-specific Schistosoma CAA strip test, allowing detection of single worm active infections (ultimate sensitivity), are discussed for efficient utilization in sample pooling strategies. Besides relevant cost reduction, pooling of samples rather than individual testing can provide valuable data for large scale mapping, surveillance, and monitoring. The laboratory-based CAA strip test utilizes luminescent quantitative up-converting phosphor (UCP) reporter particles and a rapid user-friendly lateral flow (LF) assay format. The test includes a sample preparation step that permits virtually unlimited sample concentration with urine, reaching ultimate sensitivity (single worm detection) at 100% specificity. This facilitates testing large urine pools from many individuals with minimal loss of sensitivity and specificity. The test determines the average CAA level of the individuals in the pool thus indicating overall worm burden and prevalence. When requiring test results at the individual level, smaller pools need to be analysed with the pool-size based on expected prevalence or when unknown, on the average CAA level of a larger group; CAA negative pools do not require individual test results and thus reduce the number of tests. Straightforward pooling strategies indicate that at sub-population level the CAA strip test is an efficient assay for general mapping, identification of hotspots, determination of stratified infection levels, and accurate monitoring of mass drug administrations (MDA). At the individual level, the number of tests can be reduced i.e. in low endemic settings as the pool size can be increased as opposed to prevalence decrease. At the sub-population level, average CAA concentrations determined in urine pools can be an appropriate measure indicating worm burden. Pooling strategies allowing this type of large scale testing are feasible with the various CAA strip test formats and do not affect sensitivity and specificity. It allows cost efficient stratified testing and monitoring of worm burden at the sub-population level, ideally for large-scale surveillance generating hard data for performance of MDA programs and strategic planning when moving towards transmission-stop and elimination.
Yan, Liping; Xiao, Heping; Zhang, Qing
2016-01-01
Technological advances in nucleic acid amplification have led to breakthroughs in the early detection of PTB compared to traditional sputum smear tests. The sensitivity and specificity of loop-mediated isothermal amplification (LAMP), simultaneous amplification testing (SAT), and Xpert MTB/RIF for the diagnosis of pulmonary tuberculosis were evaluated. A critical review of previous studies of LAMP, SAT, and Xpert MTB/RIF for the diagnosis of pulmonary tuberculosis that used laboratory culturing as the reference method was carried out together with a meta-analysis. In 25 previous studies, the pooled sensitivity and specificity of the diagnosis of tuberculosis were 93% and 94% for LAMP, 96% and 88% for SAT, and 89% and 98% for Xpert MTB/RIF. The I(2) values for the pooled data were >80%, indicating significant heterogeneity. In the smear-positive subgroup analysis of LAMP, the sensitivity increased from 93% to 98% (I(2) = 2.6%), and specificity was 68% (I(2) = 38.4%). In the HIV-infected subgroup analysis of Xpert MTB/RIF, the pooled sensitivity and specificity were 79% (I(2) = 72.9%) and 99% (I(2) = 64.4%). In the HIV-negative subgroup analysis for Xpert MTB/RIF, the pooled sensitivity and specificity were 72% (I(2) = 49.6%) and 99% (I(2) = 64.5%). LAMP, SAT and Xpert MTB/RIF had comparably high levels of sensitivity and specificity for the diagnosis of tuberculosis. The diagnostic sensitivity and specificity of three methods were similar, with LAMP being highly sensitive for the diagnosis of smear-positive PTB. The cost effectiveness of LAMP and SAT make them particularly suitable tests for diagnosing PTB in developing countries. Copyright © 2015 Elsevier Ltd. All rights reserved.
Vachhani, Raj; Patel, Toral; Centor, Robert M; Estrada, Carlos A
2017-01-01
Meta-analyses based on peer-reviewed publications report a sensitivity of approximately 85% for rapid antigen streptococcus tests to diagnose group A streptococcal (GAS) pharyngitis. Because these meta-analyses excluded package inserts, we examined the test characteristics of rapid antigen streptococcal tests and molecular methods that manufacturers report in their package inserts. We included tests available in the US market (Food and Drug Administration, period searched 1993-2015) and used package insert data to calculate pooled sensitivity and specificity. To examine quality, we used the Quality Assessment of Diagnostic Accuracy Studies-2. We excluded 26 tests having different trade names but identical methods and data. The study design was prospective in 41.7% (10 of 24). The pooled sensitivity of the most commonly used method, lateral flow/immunochromatographic, was 95% (95% confidence interval [CI] 94-96) and the pooled specificity was 98% (96-98); 7108 patients. The pooled sensitivity of the polymerase chain reaction or molecular methods was 98% (95% CI 96-98) and the pooled specificity was 96% (95% CI 95-97); 5685 patients. Package inserts include sponsored studies that overestimate the sensitivity of rapid tests to diagnose GAS pharyngitis by approximately 10%. Physicians should understand that package inserts overestimate diagnostic test utility; a negative test cannot be used to exclude GAS pharyngitis.
The diagnosis of food allergy: a systematic review and meta-analysis.
Soares-Weiser, K; Takwoingi, Y; Panesar, S S; Muraro, A; Werfel, T; Hoffmann-Sommergruber, K; Roberts, G; Halken, S; Poulsen, L; van Ree, R; Vlieg-Boerstra, B J; Sheikh, A
2014-01-01
We investigated the accuracy of tests used to diagnose food allergy. Skin prick tests (SPT), specific-IgE (sIgE), component-resolved diagnosis and the atopy patch test (APT) were compared with the reference standard of double-blind placebo-controlled food challenge. Seven databases were searched and international experts were contacted. Two reviewers independently identified studies, extracted data, and used QUADAS-2 to assess risk of bias. Where possible, meta-analysis was undertaken. Twenty-four (2831 participants) studies were included. For cows' milk allergy, the pooled sensitivities were 53% (95% CI 33-72), 88% (95 % CI 76-94), and 87% (95% CI 75-94), and specificities were 88% (95% CI 76-95), 68% (95% CI 56-77), and 48% (95% CI 36-59) for APT, SPT, and sIgE, respectively. For egg, pooled sensitivities were 92% (95% CI 80-97) and 93% (95% CI 82-98), and specificities were 58% (95% CI 49-67) and 49% (40-58%) for skin prick tests and specific-IgE. For wheat, pooled sensitivities were 73% (95% CI 56-85) and 83% (95% CI 69-92), and specificities were 73% (95% CI 48-89) and 43% (95% CI 20-69%) for SPT and sIgE. For soy, pooled sensitivities were 55% (95% CI 33-75) and 83% (95% CI 64-93), and specificities were 68% (95% CI 52-80) and 38% (95% CI 24-54) for SPT and sIgE. For peanut, pooled sensitivities were 95% (95% CI 88-98) and 96% (95% CI 92-98), and specificities were 61% (95% CI 47-74), and 59% (95% CI 45-72) for SPT and sIgE. The evidence base is limited and weak and is therefore difficult to interpret. Overall, SPT and sIgE appear sensitive although not specific for diagnosing IgE-mediated food allergy. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Wang, Z X; Chen, S L; Wang, Q Q; Liu, B; Zhu, J; Shen, J
2015-06-01
The aim of this study was to evaluate the accuracy of magnetic resonance imaging in the detection of triangular fibrocartilage complex injury through a meta-analysis. A comprehensive literature search was conducted before 1 April 2014. All studies comparing magnetic resonance imaging results with arthroscopy or open surgery findings were reviewed, and 25 studies that satisfied the eligibility criteria were included. Data were pooled to yield pooled sensitivity and specificity, which were respectively 0.83 and 0.82. In detection of central and peripheral tears, magnetic resonance imaging had respectively a pooled sensitivity of 0.90 and 0.88 and a pooled specificity of 0.97 and 0.97. Six high-quality studies using Ringler's recommended magnetic resonance imaging parameters were selected for analysis to determine whether optimal imaging protocols yielded better results. The pooled sensitivity and specificity of these six studies were 0.92 and 0.82, respectively. The overall accuracy of magnetic resonance imaging was acceptable. For peripheral tears, the pooled data showed a relatively high accuracy. Magnetic resonance imaging with appropriate parameters are an ideal method for diagnosing different types of triangular fibrocartilage complex tears. © The Author(s) 2015.
Colonic lesion characterization in inflammatory bowel disease: A systematic review and meta-analysis
Lord, Richard; Burr, Nicholas E; Mohammed, Noor; Subramanian, Venkataraman
2018-01-01
AIM To perform a systematic review and meta-analysis for the diagnostic accuracy of in vivo lesion characterization in colonic inflammatory bowel disease (IBD), using optical imaging techniques, including virtual chromoendoscopy (VCE), dye-based chromoendoscopy (DBC), magnification endoscopy and confocal laser endomicroscopy (CLE). METHODS We searched Medline, Embase and the Cochrane library. We performed a bivariate meta-analysis to calculate the pooled estimate sensitivities, specificities, positive and negative likelihood ratios (+LHR, -LHR), diagnostic odds ratios (DOR), and area under the SROC curve (AUSROC) for each technology group. A subgroup analysis was performed to investigate differences in real-time non-magnified Kudo pit patterns (with VCE and DBC) and real-time CLE. RESULTS We included 22 studies [1491 patients; 4674 polyps, of which 539 (11.5%) were neoplastic]. Real-time CLE had a pooled sensitivity of 91% (95%CI: 66%-98%), specificity of 97% (95%CI: 94%-98%), and an AUSROC of 0.98 (95%CI: 0.97-0.99). Magnification endoscopy had a pooled sensitivity of 90% (95%CI: 77%-96%) and specificity of 87% (95%CI: 81%-91%). VCE had a pooled sensitivity of 86% (95%CI: 62%-95%) and specificity of 87% (95%CI: 72%-95%). DBC had a pooled sensitivity of 67% (95%CI: 44%-84%) and specificity of 86% (95%CI: 72%-94%). CONCLUSION Real-time CLE is a highly accurate technology for differentiating neoplastic from non-neoplastic lesions in patients with colonic IBD. However, most CLE studies were performed by single expert users within tertiary centres, potentially confounding these results. PMID:29563760
Loomba, Rohit S; Shah, Parinda H; Nijhawan, Karan; Aggarwal, Saurabh; Arora, Rohit
2015-03-01
Increased cardiothoracic ratio noted on chest radiographs often prompts concern and further evaluation with additional imaging. This study pools available data assessing the utility of cardiothoracic ratio in predicting left ventricular dilation. A systematic review of the literature was conducted to identify studies comparing cardiothoracic ratio by chest x-ray to left ventricular dilation by echocardiography. Electronic databases were used to identify studies which were then assessed for quality and bias, with those with adequate quality and minimal bias ultimately being included in the pooled analysis. The pooled data were used to determine the sensitivity, specificity, positive predictive value and negative predictive value of cardiomegaly in predicting left ventricular dilation. A total of six studies consisting of 466 patients were included in this analysis. Cardiothoracic ratio had 83.3% sensitivity, 45.4% specificity, 43.5% positive predictive value and 82.7% negative predictive value. When a secondary analysis was conducted with a pediatric study excluded, a total of five studies consisting of 371 patients were included. Cardiothoracic ratio had 86.2% sensitivity, 25.2% specificity, 42.5% positive predictive value and 74.0% negative predictive value. Cardiothoracic ratio as determined by chest radiograph is sensitive but not specific for identifying left ventricular dilation. Cardiothoracic ratio also has a strong negative predictive value for identifying left ventricular dilation.
Zhou, Zhiran; Zhang, Huitian; Lei, Yunxia
2016-10-01
To evaluate the diagnostic value of secreted frizzled-related protein 2 (SFRP2) gene promoter hypermethylation in stool for colorectal cancer (CRC). Open published diagnostic study of SFRP2 gene promoter hypermethylation in stool for CRC detection was electronic searched in the databases of PubMed, EMBASE, Cochrane Library, Web of Science, and China National Knowledge Infrastructure. The data of true positive, false positive false negative, and true negative identified by stool SFRP2 gene hypermethylation was extracted and pooled for diagnostic sensitivity, specificity, and summary receiver operating characteristic (SROC) curve. According to the inclusion and exclusion criteria, we finally included nine publications with 792 cases in the meta-analysis. Thus, the diagnostic sensitivity was aggregated through random effect model. The pooled sensitivity was 0.82 with the corresponding 95% confidence interval (95% CI) of 0.79-0.85; the pooled specificity and its corresponding 95% CI were 0.47 and 0.40-0.53 by the random effect model; we pooled the SROC curve by sensitivity versus specificity according to data published in the nine studies. The area under the SROC curve was 0.70 (95% CI: 0.65-0.73). SFRP2 gene promoter hypermethylation in stool can was a potential biomarker for CRC diagnosis with relative high sensitivity.
Marson, B A; Deshmukh, S R; Grindlay, D J C; Scammell, B E
2018-06-01
Aims The aim of this review was to evaluate the available literature and to calculate the pooled sensitivity and specificity for the different alpha-defensin test systems that may be used to diagnose prosthetic joint infection (PJI). Materials and Methods Studies using alpha-defensin or Synovasure (Zimmer Biomet, Warsaw, Indiana) to diagnose PJI were identified from systematic searches of electronic databases. The quality of the studies was evaluated using the Quality Assessment of Studies of Diagnostic Accuracy (QUADAS) tool. Meta-analysis was completed using a bivariate model. Results A total of 11 eligible studies were included. The median QUADAS score was 13 (interquartile range 13 to 13) out of 14. Significant conflicts of interest were identified in five studies. The pooled sensitivity for the laboratory alpha-defensin test was 0.95 (95% confidence interval (CI) 0.91 to 0.98) and the pooled specificity was 0.97 (95% CI 0.95 to 0.98) for four studies with a threshold level of 5.2 mgl -1 The pooled sensitivity for the lateral flow cassette test was 0.85 (95% CI 0.74 to 0.92) and the pooled specificity was 0.90 (95% CI 0.91 to 0.98). There was a statistically significant difference in sensitivity (p = 0.019), but not specificity (p = 0.47). Conclusion Laboratory-based alpha-defensin testing remains a promising tool for diagnosing PJI. The lateral flow cassette has a significantly lower performance and pooled results are comparable to the leucocyte esterase test. Further studies are required before the widespread adoption of the lateral flow cassette alpha-defensin test. Cite this article: Bone Joint J 2018;100-B:703-11.
Steingart, Karen R.; Flores, Laura L.; Dendukuri, Nandini; Schiller, Ian; Laal, Suman; Ramsay, Andrew; Hopewell, Philip C.; Pai, Madhukar
2011-01-01
Background Serological (antibody detection) tests for tuberculosis (TB) are widely used in developing countries. As part of a World Health Organization policy process, we performed an updated systematic review to assess the diagnostic accuracy of commercial serological tests for pulmonary and extrapulmonary TB with a focus on the relevance of these tests in low- and middle-income countries. Methods and Findings We used methods recommended by the Cochrane Collaboration and GRADE approach for rating quality of evidence. In a previous review, we searched multiple databases for papers published from 1 January 1990 to 30 May 2006, and in this update, we add additional papers published from that period until 29 June 2010. We prespecified subgroups to address heterogeneity and summarized test performance using bivariate random effects meta-analysis. For pulmonary TB, we included 67 studies (48% from low- and middle-income countries) with 5,147 participants. For all tests, estimates were variable for sensitivity (0% to 100%) and specificity (31% to 100%). For anda-TB IgG, the only test with enough studies for meta-analysis, pooled sensitivity was 76% (95% CI 63%–87%) in smear-positive (seven studies) and 59% (95% CI 10%–96%) in smear-negative (four studies) patients; pooled specificities were 92% (95% CI 74%–98%) and 91% (95% CI 79%–96%), respectively. Compared with ELISA (pooled sensitivity 60% [95% CI 6%–65%]; pooled specificity 98% [95% CI 96%–99%]), immunochromatographic tests yielded lower pooled sensitivity (53%, 95% CI 42%–64%) and comparable pooled specificity (98%, 95% CI 94%–99%). For extrapulmonary TB, we included 25 studies (40% from low- and middle-income countries) with 1,809 participants. For all tests, estimates were variable for sensitivity (0% to 100%) and specificity (59% to 100%). Overall, quality of evidence was graded very low for studies of pulmonary and extrapulmonary TB. Conclusions Despite expansion of the literature since 2006, commercial serological tests continue to produce inconsistent and imprecise estimates of sensitivity and specificity. Quality of evidence remains very low. These data informed a recently published World Health Organization policy statement against serological tests. Please see later in the article for the Editors' Summary PMID:21857806
Shi, Ruo-Yang; Yao, Qiu-Ying; Wu, Lian-Ming; Xu, Jian-Rong
2018-06-01
We compared the diagnostic performance of diffusion weighted imaging (DWI) acquired with 1.5T and 3.0T magnetic resonance (MR) units in differentiating malignant breast lesions from benign ones. A comprehensive search of the PubMed and Embase databases was performed for studies reported from January 1, 2000 to February 19, 2016. The quality of the included studies was assessed. Statistical analysis included pooling of diagnostic sensitivity and specificity and assessing data inhomogeneity and publication bias. A total of 61 studies were included after a full-text review. These included 4778 patients and 5205 breast lesions. The overall sensitivity and specificity were 90% (95% confidence interval [CI], 88%-92%) and 86% (95% CI, 82%-89%), respectively. The pooled diagnostic odds ratio was 53 (95% CI, 37-74). For breast cancer versus benign lesions, the area under the curve was 0.94 (95% CI, 0.92-0.96). For the 44 studies that used a 1.5T MR unit, the pooled sensitivity and specificity were 91% (95% CI, 89%-92%) and 86% (95% CI, 81%-90%), respectively. For the 17 studies that used a 3.0T MR unit, the pooled sensitivity and specificity were 88% (95% CI, 83%-91%) and 84% (95% CI, 0.78-0.89), respectively. Publication bias and significant heterogeneity were observed; however, no threshold was found among the 61 studies. No significant difference was found in the sensitivity or specificity between the subgroups. The results of the comparison between the subgroups that had used either a 1.5T or 3.0T MR unit suggest that the diagnostic accuracy for breast cancer compared with benign lesions is not significantly different. Copyright © 2017 Elsevier Inc. All rights reserved.
Zhang, Li; Tang, Min; Min, Zhiqian; Lu, Jun; Lei, Xiaoyan; Zhang, Xiaoling
2016-06-01
Magnetic resonance imaging (MRI) is increasingly being used to examine patients with suspected breast cancer. To determine the diagnostic performance of combined dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and diffusion-weighted imaging (DWI) for breast cancer detection. A comprehensive search of the PUBMED, EMBASE, Web of Science, and Cochrane Library databases was performed up to September 2014. Statistical analysis included pooling of sensitivity and specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and diagnostic accuracy using the summary receiver operating characteristic (SROC). All analyses were conducted using STATA (version 12.0), RevMan (version 5.2), and Meta-Disc 1.4 software programs. Fourteen studies were analyzed, which included a total of 1140 patients with 1276 breast lesions. The pooled sensitivity and specificity of combined DCE-MRI and DWI were 91.6% and 85.5%, respectively. The pooled sensitivity and specificity of DWI-MRI were 86.0% and 75.6%, respectively. The pooled sensitivity and specificity of DCE-MRI were 93.2% and 71.1%. The area under the SROC curve (AUC-SROC) of combined DCE-MRI and DWI was 0.94, the DCE-MRI of 0.85. Deeks testing confirmed no significant publication bias in all studies. Combined DCE-MRI and DWI had superior diagnostic accuracy than either DCE-MRI or DWI alone for the diagnosis of breast cancer. © The Foundation Acta Radiologica 2015.
Guerriero, S; Saba, L; Pascual, M A; Ajossa, S; Rodriguez, I; Mais, V; Alcazar, J L
2018-05-01
To perform a systematic review of studies comparing the accuracy of transvaginal ultrasound (TVS) and magnetic resonance imaging (MRI) in diagnosing deep infiltrating endometriosis (DIE) including only studies in which patients underwent both techniques. An extensive search was carried out in PubMed/MEDLINE and Web of Science for papers from January 1989 to October 2016 comparing TVS and MRI in DIE. Studies were considered eligible for inclusion if they reported on the use of TVS and MRI in the same set of patients for the preoperative detection of endometriosis in pelvic locations in women with clinical suspicion of DIE and using surgical data as a reference standard. Quality was assessed using the QUADAS-2 tool. A random-effects model was used to determine pooled sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR-) and diagnostic odds ratio (DOR). Of 375 citations identified, six studies (n = 424) were considered eligible. For MRI in the detection of DIE in the rectosigmoid, pooled sensitivity was 0.85 (95% CI, 0.78-0.90), specificity was 0.95 (95% CI, 0.83-0.99), LR+ was 18.4 (95% CI, 4.7-72.4), LR- was 0.16 (95% CI, 0.11-0.24) and DOR was 116 (95% CI, 23-585). For TVS in the detection of DIE in the rectosigmoid, pooled sensitivity was 0.85 (95% CI, 0.68-0.94), specificity was 0.96 (95% CI, 0.85-0.99), LR+ was 20.4 (95% CI, 4.7-88.5), LR- was 0.16 (95% CI, 0.07-0.38) and DOR was 127 (95% CI, 14-1126). For MRI in the detection of DIE in the rectovaginal septum, pooled sensitivity was 0.66 (95% CI, 0.51-0.79), specificity was 0.97 (95% CI, 0.89-0.99), LR+ was 22.5 (95% CI, 6.7-76.2), LR- was 0.38 (95% CI, 0.23-0.52) and DOR was 65 (95% CI, 21-204). For TVS in the detection of DIE in the rectovaginal septum, pooled sensitivity was 0.59 (95% CI, 0.26-0.86), specificity was 0.97 (95% CI, 0.94-0.99), LR+ was 23.5 (95% CI, 9.1-60.5), LR- was 0.42 (95% CI, 0.18-0.97) and DOR was 56 (95% CI, 11-275). For MRI in the detection of DIE in the uterosacral ligaments, pooled sensitivity was 0.70 (95% CI, 0.55-0.82), specificity was 0.93 (95% CI, 0.87-0.97), LR+ was 10.4 (95% CI, 5.1-21.2), LR- was 0.32 (95% CI, 0.20-0.51) and DOR was 32 (95% CI, 12-85). For TVS in the detection of DIE in the uterosacral ligaments, pooled sensitivity was 0.67 (95% CI, 0.55-0.77), specificity was 0.86 (95% CI, 0.73-0.93), LR+ was 4.8 (95% CI, 2.6-9.0), LR- was 0.38 (95% CI, 0.29-0.50) and DOR was 12 (95% CI, 7-24). Confidence intervals of pooled sensitivities, specificities and DOR were wide for both techniques in all the locations considered. Heterogeneity was moderate or high for sensitivity and specificity for both TVS and MRI in most locations assessed. According to QUADAS-2, the quality of the included studies was considered good for most domains. The diagnostic performance of TVS and MRI is similar for detecting DIE involving rectosigmoid, uterosacral ligaments and rectovaginal septum. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
Shifted Transversal Design smart-pooling for high coverage interactome mapping
Xin, Xiaofeng; Rual, Jean-François; Hirozane-Kishikawa, Tomoko; Hill, David E.; Vidal, Marc; Boone, Charles; Thierry-Mieg, Nicolas
2009-01-01
“Smart-pooling,” in which test reagents are multiplexed in a highly redundant manner, is a promising strategy for achieving high efficiency, sensitivity, and specificity in systems-level projects. However, previous applications relied on low redundancy designs that do not leverage the full potential of smart-pooling, and more powerful theoretical constructions, such as the Shifted Transversal Design (STD), lack experimental validation. Here we evaluate STD smart-pooling in yeast two-hybrid (Y2H) interactome mapping. We employed two STD designs and two established methods to perform ORFeome-wide Y2H screens with 12 baits. We found that STD pooling achieves similar levels of sensitivity and specificity as one-on-one array-based Y2H, while the costs and workloads are divided by three. The screening-sequencing approach is the most cost- and labor-efficient, yet STD identifies about twofold more interactions. Screening-sequencing remains an appropriate method for quickly producing low-coverage interactomes, while STD pooling appears as the method of choice for obtaining maps with higher coverage. PMID:19447967
Scott, T.W.; Olson, J.G.; Lewis, T.E.; Carpenter, J.W.; Lorenz, L.H.; Lembeck, L.A.; Joseph, S.R.; Pagac, B.B.
1987-01-01
A prospective field study was conducted to determine the sensitivity and specificity of an enzyme immunoassay (EIA) compared to virus isolation in cell culture for the detection of eastern equine encephalomyelitis (EEE) virus in naturally infected mosquitoes. A total of 10,811 adult female Culiseta melanura were collected in light traps during 1985 from four locations in Maryland. Eastern equine encephalomyelitis virus was isolated from 5 of 495 mosquito pools in African green monkey kidney and baby hamster kidney cell cultures. All five virus-infected pools were detected by the EIA, and all 490 uninfected pools were correctly scored as not containing virus. The EIA did not produce false positive or false negative results. Results support the assertion of previous researchers that the antigen detection EIA is a rapid, sensitive, specific, and simple alternative to traditional bioassays for the detection of EEE virus in mosquitoes.
Fang, Y G; Chen, N N; Cheng, Y B; Sun, S J; Li, H X; Sun, F; Xiang, Y
2015-12-01
Urinary neutrophil gelatinase-associated lipocalin (uNGAL) is relatively specific in lupus nephritis (LN) patients. However, its diagnostic value has not been evaluated. The aim of this review was to determine the value of uNGAL for diagnosis and estimating activity in LN. A comprehensive search was performed on PubMed, EMBASE, Web of Knowledge, Cochrane electronic databases through December 2014. Meta-analysis of sensitivity and specificity was performed with a random-effects model. Additionally, summary receiver operating characteristic (SROC) curves and area under the curve (AUC) values were calculated. Fourteen studies were selected for this review. With respect to diagnosing LN, the pooled sensitivity and specificity were 73.6% (95% confidence interval (CI), 61.9-83.3) and 78.1% (95% CI, 69.0-85.6), respectively. The SROC-AUC value was 0.8632. Regarding estimating LN activity, the pooled sensitivity and specificity were 66.2% (95% CI, 60.4-71.7) and 62.1% (95% CI, 57.9-66.3), respectively. The SROC-AUC value was 0.7583. In predicting renal flares, the pooled sensitivity and specificity were 77.5% (95% CI, 68.1-85.1) and 65.3% (95% CI, 60.0-70.3), respectively. The SROC-AUC value was 0.7756. In conclusion, this meta-analysis indicates that uNGAL has relatively fair sensitivity and specificity in diagnosing LN, estimating LN activity and predicting renal flares, suggesting that uNGAL is a potential biomarker in diagnosing LN and monitoring LN activity. © The Author(s) 2015.
Suh, Chong Hyun; Yun, Seong Jong; Jin, Wook; Lee, Sun Hwa; Park, So Young; Ryu, Chang-Woo
2018-07-01
To assess the sensitivity and specificity of quantitative assessment of the apparent diffusion coefficient (ADC) for differentiating benign and malignant vertebral bone marrow lesions (BMLs) and compression fractures (CFs) METHODS: An electronic literature search of MEDLINE and EMBASE was conducted. Bivariate modelling and hierarchical summary receiver operating characteristic modelling were performed to evaluate the diagnostic performance of ADC for differentiating vertebral BMLs. Subgroup analysis was performed for differentiating benign and malignant vertebral CFs. Meta-regression analyses according to subject, study and diffusion-weighted imaging (DWI) characteristics were performed. Twelve eligible studies (748 lesions, 661 patients) were included. The ADC exhibited a pooled sensitivity of 0.89 (95% confidence interval [CI] 0.80-0.94) and a pooled specificity of 0.87 (95% CI 0.78-0.93) for differentiating benign and malignant vertebral BMLs. In addition, the pooled sensitivity and specificity for differentiating benign and malignant CFs were 0.92 (95% CI 0.82-0.97) and 0.91 (95% CI 0.87-0.94), respectively. In the meta-regression analysis, the DWI slice thickness was a significant factor affecting heterogeneity (p < 0.01); thinner slice thickness (< 5 mm) showed higher specificity (95%) than thicker slice thickness (81%). Quantitative assessment of ADC is a useful diagnostic tool for differentiating benign and malignant vertebral BMLs and CFs. • Quantitative assessment of ADC is useful in differentiating vertebral BMLs. • Quantitative ADC assessment for BMLs had sensitivity of 89%, specificity of 87%. • Quantitative ADC assessment for CFs had sensitivity of 92%, specificity of 91%. • The specificity is highest (95%) with thinner (< 5 mm) DWI slice thickness.
Occult HBV infection in HIV-infected adults and evaluation of pooled NAT for HBV.
Dinesha, T R; Boobalan, J; Sivamalar, S; Subashini, D; Solomon, S S; Murugavel, K G; Balakrishnan, P; Smith, D M; Saravanan, S
2018-06-01
The study aimed to determine the prevalence of occult hepatitis B virus infection among HIV-infected persons and to evaluate the use of a pooling strategy to detect occult HBV infection in the setting of HIV infection. Five hundred and two HIV-positive individuals were tested for HBV, occult HBV and hepatitis C and D with serologic and nucleic acid testing (NAT). We also evaluated a pooled NAT strategy for screening occult HBV infection among the HIV-positive individuals. The prevalence of HBV infection among HIV-positive individuals was 32 (6.4%), and occult HBV prevalence was 10%. The pooling HBV NAT had a sensitivity of 66.7% and specificity of 100%, compared to HBV DNA NAT of individual samples. In conclusion, this study found a high prevalence of occult HBV infection among our HIV-infected population. We also demonstrated that pooled HBV NAT is highly specific, moderately sensitive and cost-effective. As conventional HBV viral load assays are expensive in resource-limited settings such as India, pooled HBV DNA NAT might be a good way for detecting occult HBV infection and will reduce HBV-associated complications. © 2018 John Wiley & Sons Ltd.
Levitt, Jacob Oren; Levitt, Barrie H.; Akhavan, Arash; Yanofsky, Howard
2010-01-01
Background. There are relatively few studies published examining the sensitivity and specificity of potassium hydroxide (KOH) smear and fungal culture examination of tinea pedis. Objective. To evaluate the sensitivity and specificity of KOH smear and fungal culture for diagnosing tinea pedis. Methods. A pooled analysis of data from five similarly conducted bioequivalence trials for antifungal drugs was performed. Data from 460 patients enrolled in the vehicle arms of these studies with clinical diagnosis of tinea pedis supported by positive fungal culture were analyzed 6 weeks after initiation of the study to determine the sensitivity and specificity of KOH smear and fungal culture. Results. Using clinical assessment as the gold standard, the sensitivities for KOH smear and culture were 73.3% (95% CI: 66.3 to 79.5%) and 41.7% (34.6 to 49.1%), respectively. The respective specificities for culture and KOH smear were 77.7% (72.2 to 82.5%) and 42.5% (36.6 to 48.6%). Conclusion. KOH smear and fungal culture are complementary diagnostic tests for tinea pedis, with the former being the more sensitive test of the two, and the latter being more specific. PMID:20672004
Cudahy, Patrick G.T; Schumacher, Samuel G.; Steingart, Karen R.; Pai, Madhukar; Denkinger, Claudia M.
2017-01-01
Only 25% of multidrug-resistant tuberculosis (MDR-TB) cases are currently diagnosed. Line probe assays (LPAs) enable rapid drug-susceptibility testing for rifampicin (RIF) and isoniazid (INH) resistance and Mycobacterium tuberculosis detection. Genotype MTBDRplusV1 was WHO-endorsed in 2008 but newer LPAs have since been developed. This systematic review evaluated three LPAs: Hain Genotype MTBDRplusV1, MTBDRplusV2 and Nipro NTM+MDRTB. Study quality was assessed with QUADAS-2. Bivariate random-effects meta-analyses were performed for direct and indirect testing. Results for RIF and INH resistance were compared to phenotypic and composite (incorporating sequencing) reference standards. M. tuberculosis detection results were compared to culture. 74 unique studies were included. For RIF resistance (21 225 samples), pooled sensitivity and specificity (with 95% confidence intervals) were 96.7% (95.6–97.5%) and 98.8% (98.2–99.2%). For INH resistance (20 954 samples), pooled sensitivity and specificity were 90.2% (88.2–91.9%) and 99.2% (98.7–99.5%). Results were similar for direct and indirect testing and across LPAs. Using a composite reference standard, specificity increased marginally. For M. tuberculosis detection (3451 samples), pooled sensitivity was 94% (89.4–99.4%) for smear-positive specimens and 44% (20.2–71.7%) for smear-negative specimens. In patients with pulmonary TB, LPAs have high sensitivity and specificity for RIF resistance and high specificity and good sensitivity for INH resistance. This meta-analysis provides evidence for policy and practice. PMID:28100546
Sepriano, Alexandre; Rubio, Roxana; Ramiro, Sofia; Landewé, Robert; van der Heijde, Désirée
2017-05-01
To summarise the evidence on the performance of the Assessment of SpondyloArthritis international Society (ASAS) classification criteria for axial spondyloarthritis (axSpA) (also imaging and clinical arm separately), peripheral (p)SpA and the entire set, when tested against the rheumatologist's diagnosis ('reference standard'). A systematic literature review was performed to identify eligible studies. Raw data on SpA diagnosis and classification were extracted or, if necessary, obtained from the authors of the selected publications. A meta-analysis was performed to obtain pooled estimates for sensitivity, specificity, positive and negative likelihood ratios, by fitting random effects models. Nine papers fulfilled the inclusion criteria (N=5739 patients). The entire set of the ASAS SpA criteria yielded a high pooled sensitivity (73%) and specificity (88%). Similarly, good results were found for the axSpA criteria (sensitivity: 82%; specificity: 88%). Splitting the axSpA criteria in 'imaging arm only' and 'clinical arm only' resulted in much lower sensitivity (30% and 23% respectively), but very high specificity was retained (97% and 94% respectively). The pSpA criteria were less often tested than the axSpA criteria and showed a similarly high pooled specificity (87%) but lower sensitivity (63%). Accumulated evidence from studies with more than 5500 patients confirms the good performance of the various ASAS SpA criteria as tested against the rheumatologist's diagnosis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Bazot, Marc; Daraï, Emile
2018-03-01
The aim of the present review, conducted according to PRISMA statement recommendations, was to evaluate the contribution of transvaginal sonography (TVS) and magnetic resonance imaging (MRI) to diagnose adenomyosis. Although there is a lack of consensus on adenomyosis classification, three subtypes are described, internal, external adenomyosis, and adenomyomas. Using TVS, whatever the subtype, pooled sensitivities, pooled specificities, and pooled positive likelihood ratios are 0.72-0.82, 0.85-0.81, and 4.67-3.7, respectively, but with a high heterogeneity between the studies. MRI has a pooled sensitivity of 0.77, specificity of 0.89, positive likelihood ratio of 6.5, and negative likelihood ratio of 0.2 for all subtypes. Our results suggest that MRI is more useful than TVS in the diagnosis of adenomyosis. Further studies are required to determine the performance of direct signs (cystic component) and indirect signs (characteristics of junctional zone) to avoid misdiagnosis of adenomyosis. Copyright © 2018 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
The diagnostic value of narrow-band imaging for early and invasive lung cancer: a meta-analysis.
Zhu, Juanjuan; Li, Wei; Zhou, Jihong; Chen, Yuqing; Zhao, Chenling; Zhang, Ting; Peng, Wenjia; Wang, Xiaojing
2017-07-01
This study aimed to compare the ability of narrow-band imaging to detect early and invasive lung cancer with that of conventional pathological analysis and white-light bronchoscopy. We searched the PubMed, EMBASE, Sinomed, and China National Knowledge Infrastructure databases for relevant studies. Meta-disc software was used to perform data analysis, meta-regression analysis, sensitivity analysis, and heterogeneity testing, and STATA software was used to determine if publication bias was present, as well as to calculate the relative risks for the sensitivity and specificity of narrow-band imaging vs those of white-light bronchoscopy for the detection of early and invasive lung cancer. A random-effects model was used to assess the diagnostic efficacy of the above modalities in cases in which a high degree of between-study heterogeneity was noted with respect to their diagnostic efficacies. The database search identified six studies including 578 patients. The pooled sensitivity and specificity of narrow-band imaging were 86% (95% confidence interval: 83-88%) and 81% (95% confidence interval: 77-84%), respectively, and the pooled sensitivity and specificity of white-light bronchoscopy were 70% (95% confidence interval: 66-74%) and 66% (95% confidence interval: 62-70%), respectively. The pooled relative risks for the sensitivity and specificity of narrow-band imaging vs the sensitivity and specificity of white-light bronchoscopy for the detection of early and invasive lung cancer were 1.33 (95% confidence interval: 1.07-1.67) and 1.09 (95% confidence interval: 0.84-1.42), respectively, and sensitivity analysis showed that narrow-band imaging exhibited good diagnostic efficacy with respect to detecting early and invasive lung cancer and that the results of the study were stable. Narrow-band imaging was superior to white light bronchoscopy with respect to detecting early and invasive lung cancer; however, the specificities of the two modalities did not differ significantly.
Huang, Wei; Altaf, Kiran; Jin, Tao; Xiong, Jun-Jie; Wen, Li; Javed, Muhammad A; Johnstone, Marianne; Xue, Ping; Halloran, Christopher M; Xia, Qing
2013-01-01
AIM: To undertake a meta-analysis on the value of urinary trypsinogen activation peptide (uTAP) in predicting severity of acute pancreatitis on admission. METHODS: Major databases including Medline, Embase, Science Citation Index Expanded and the Cochrane Central Register of Controlled Trials in the Cochrane Library were searched to identify all relevant studies from January 1990 to January 2013. Pooled sensitivity, specificity and the diagnostic odds ratios (DORs) with 95%CI were calculated for each study and were compared to other systems/biomarkers if mentioned within the same study. Summary receiver-operating curves were conducted and the area under the curve (AUC) was evaluated. RESULTS: In total, six studies of uTAP with a cut-off value of 35 nmol/L were included in this meta-analysis. Overall, the pooled sensitivity and specificity of uTAP for predicting severity of acute pancreatitis, at time of admission, was 71% and 75%, respectively (AUC = 0.83, DOR = 8.67, 95%CI: 3.70-20.33). When uTAP was compared with plasma C-reactive protein, the pooled sensitivity, specificity, AUC and DOR were 0.64 vs 0.67, 0.77 vs 0.75, 0.82 vs 0.79 and 6.27 vs 6.32, respectively. Similarly, the pooled sensitivity, specificity, AUC and DOR of uTAP vs Acute Physiology and Chronic Health Evaluation II within the first 48 h of admission were found to be 0.64 vs 0.69, 0.77 vs 0.61, 0.82 vs 0.73 and 6.27 vs 4.61, respectively. CONCLUSION: uTAP has the potential to act as a stratification marker on admission for differentiating disease severity of acute pancreatitis. PMID:23901239
Zhai, Rong-Lin; Xu, Fei; Zhang, Pei; Zhang, Wan-Li; Wang, Hui; Wang, Ji-Liang; Cai, Kai-Lin; Long, Yue-Ping; Lu, Xiao-Ming; Tao, Kai-Xiong; Wang, Guo-Bin
2016-02-01
This meta-analysis was designed to evaluate the diagnostic performance of stool DNA testing for colorectal cancer (CRC) and compare the performance between single-gene and multiple-gene tests.MEDLINE, Cochrane, EMBASE databases were searched using keywords colorectal cancers, stool/fecal, sensitivity, specificity, DNA, and screening. Sensitivity analysis, quality assessments, and performance bias were performed for the included studies.Fifty-three studies were included in the analysis with a total sample size of 7524 patients. The studies were heterogeneous with regard to the genes being analyzed for fecal genetic biomarkers of CRC, as well as the laboratory methods being used for each assay. The sensitivity of the different assays ranged from 2% to 100% and the specificity ranged from 81% to 100%. The meta-analysis found that the pooled sensitivities for single- and multigene assays were 48.0% and 77.8%, respectively, while the pooled specificities were 97.0% and 92.7%. Receiver operator curves and diagnostic odds ratios showed no significant difference between both tests with regard to sensitivity or specificity.This meta-analysis revealed that using assays that evaluated multiple genes compared with single-gene assays did not increase the sensitivity or specificity of stool DNA testing in detecting CRC.
Guerriero, S; Ajossa, S; Minguez, J A; Jurado, M; Mais, V; Melis, G B; Alcazar, J L
2015-11-01
To review the diagnostic accuracy of transvaginal ultrasound (TVS) in the preoperative detection of endometriosis in the uterosacral ligaments (USL), rectovaginal septum (RVS), vagina and bladder in patients with clinical suspicion of deep infiltrating endometriosis (DIE). An extensive search was performed in MEDLINE (PubMed) and EMBASE for studies published between January 1989 and December 2014. Studies were considered eligible if they reported on the use of TVS for the preoperative detection of endometriosis in the USL, RVS, vagina and bladder in women with clinical suspicion of DIE using the surgical data as a reference standard. Study quality was assessed using the PRISMA guidelines and QUADAS-2 tool. Of the 801 citations identified, 11 studies (n = 1583) were considered eligible and were included in the meta-analysis. For detection of endometriosis in the USL, the overall pooled sensitivity and specificity of TVS were 53% (95%CI, 35-70%) and 93% (95%CI, 83-97%), respectively. The pretest probability of USL endometriosis was 54%, which increased to 90% when suspicion of endometriosis was present after TVS examination. For detection of endometriosis in the RVS, the overall pooled sensitivity and specificity were 49% (95%CI, 36-62%) and 98% (95%CI, 95-99%), respectively. The pretest probability of RVS endometriosis was 24%, which increased to 89% when suspicion of endometriosis was present after TVS examination. For detection of vaginal endometriosis, the overall pooled sensitivity and specificity were 58% (95%CI, 40-74%) and 96% (95%CI, 87-99%), respectively. The pretest probability of vaginal endometriosis was 17%, which increased to 76% when suspicion of endometriosis was present after TVS assessment. Substantial heterogeneity was found for sensitivity and specificity for all these locations. For detection of bladder endometriosis, the overall pooled sensitivity and specificity were 62% (95%CI, 40-80%) and 100% (95%CI, 97-100%), respectively. Moderate heterogeneity was found for sensitivity and specificity for bladder endometriosis. The pretest probability of bladder endometriosis was 5%, which increased to 92% when suspicion of endometriosis was present after TVS assessment. Overall diagnostic performance of TVS for detecting DIE in uterosacral ligaments, rectovaginal septum, vagina and bladder is fair with high specificity. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Horita, Nobuyuki; Miyazawa, Naoki; Kojima, Ryota; Kimura, Naoko; Inoue, Miyo; Ishigatsubo, Yoshiaki; Kaneko, Takeshi
2013-11-01
Studies on the sensitivity and specificity of the Binax Now Streptococcus pneumonia urinary antigen test (index test) show considerable variance of results. Those written in English provided sufficient original data to evaluate the sensitivity and specificity of the index test using unconcentrated urine to identify S. pneumoniae infection in adults with pneumonia. Reference tests were conducted with at least one culture and/or smear. We estimated sensitivity and two specificities. One was the specificity evaluated using only patients with pneumonia of identified other aetiologies ('specificity (other)'). The other was the specificity evaluated based on both patients with pneumonia of unknown aetiology and those with pneumonia of other aetiologies ('specificity (unknown and other)') using a fixed model for meta-analysis. We found 10 articles involving 2315 patients. The analysis of 10 studies involving 399 patients yielded a pooled sensitivity of 0.75 (95% confidence interval: 0.71-0.79) without heterogeneity or publication bias. The analysis of six studies involving 258 patients yielded a pooled specificity (other) of 0.95 (95% confidence interval: 0.92-0.98) without no heterogeneity or publication bias. We attempted to conduct a meta-analysis with the 10 studies involving 1916 patients to estimate specificity (unknown and other), but it remained unclear due to moderate heterogeneity and possible publication bias. In our meta-analysis, sensitivity of the index test was moderate and specificity (other) was high; however, the specificity (unknown and other) remained unclear. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.
Emile, Sameh H; Elfeki, Hossam; Shalaby, Mostafa; Sakr, Ahmad; Sileri, Pierpaolo; Laurberg, Søren; Wexner, Steven D
2017-11-01
This review aimed to determine the overall sensitivity and specificity of indocyanine green (ICG) near-infrared (NIR) fluorescence in sentinel lymph node (SLN) detection in Colorectal cancer (CRC). A systematic search in electronic databases was conducted. Twelve studies including 248 patients were reviewed. The median sensitivity, specificity, and accuracy rates were 73.7, 100, and 75.7. The pooled sensitivity and specificity rates were 71% and 84.6%. In conclusion, ICG-NIR fluorescence is a promising technique for detecting SLNs in CRC. © 2017 Wiley Periodicals, Inc.
Casarin, Elisabetta; Lucchese, Laura; Grazioli, Santina; Facchin, Sonia; Realdon, Nicola; Brocchi, Emiliana; Morpurgo, Margherita; Nardelli, Stefano
2016-01-01
Diagnostic tests for veterinary surveillance programs should be efficient, easy to use and, possibly, economical. In this context, classic Enzyme linked ImmunoSorbent Assay (ELISA) remains the most common analytical platform employed for serological analyses. The analysis of pooled samples instead of individual ones is a common procedure that permits to certify, with one single test, entire herds as "disease-free". However, diagnostic tests for pooled samples need to be particularly sensitive, especially when the levels of disease markers are low, as in the case of anti-BoHV1 antibodies in milk as markers of Infectious Bovine Rhinotracheitis (IBR) disease. The avidin-nucleic-acid-nanoassembly (ANANAS) is a novel kind of signal amplification platform for immunodiagnostics based on colloidal poly-avidin nanoparticles that, using model analytes, was shown to strongly increase ELISA test performance as compared to monomeric avidin. Here, for the first time, we applied the ANANAS reagent integration in a real diagnostic context. The monoclonal 1G10 anti-bovine IgG1 antibody was biotinylated and integrated with the ANANAS reagents for indirect IBR diagnosis from pooled milk mimicking tank samples from herds with IBR prevalence between 1 to 8%. The sensitivity and specificity of the ANANAS integrated method was compared to that of a classic test based on the same 1G10 antibody directly linked to horseradish peroxidase, and a commercial IDEXX kit recently introduced in the market. ANANAS integration increased by 5-fold the sensitivity of the 1G10 mAb-based conventional ELISA without loosing specificity. When compared to the commercial kit, the 1G10-ANANAS integrated method was capable to detect the presence of anti-BHV1 antibodies from bulk milk of gE antibody positive animals with 2-fold higher sensitivity and similar specificity. The results demonstrate the potentials of this new amplification technology, which permits improving current classic ELISA sensitivity limits without the need for new hardware investments.
Knipping, Karen; Simons, Peter J; Buelens-Sleumer, Laura S; Cox, Linda; den Hartog, Marcel; de Jong, Niels; Teshima, Reiko; Garssen, Johan; Boon, Louis; Knippels, Léon M J
2014-01-01
Cow's milk-derived whey hydrolysates are nutritional substitutes for allergic infants. Safety or residual allergenicity assessment of these whey hydrolysates is crucial. Currently, rat basophilic leukemia RBL-2H3 cells expressing the human IgE receptor α-chain (huFcεRIα-RBL-2H3), sensitized with serum IgE from cow's milk allergic children, are being employed to assess in vitro residual allergenicity of these whey hydrolysates. However, limited availability and inter-lot variation of these allergic sera impede standardization of whey hydrolysate safety testing in degranulation assays. An oligoclonal pool of chimeric human (chu)IgE antibodies against bovine β-lactoglobulin (a major allergen in whey) was generated to increase sensitivity, specificity, and reproducibility of existing degranulation assays. Mice were immunized with bovine β-lactoglobulin, and subsequently the variable domains of dissimilar anti-β-lactoglobulin mouse IgG antibodies were cloned and sequenced. Six chimeric antibodies were generated comprising mouse variable domains and human constant IgE/κ domains. After sensitization with this pool of anti-β-lactoglobulin chuIgEs, huFcεRIα-expressing RBL-2H3 cells demonstrated degranulation upon cross-linking with whey, native 18 kDa β-lactoglobulin, and 5-10 kDa whey hydrolysates, whereas a 3 kDa whey hydrolysate and cow's milk powder (mainly casein) showed no degranulation. In parallel, allergic serum IgEs were less sensitive. In addition, our pool anti-β-lactoglobulin chuIgEs recognized multiple allergenic immunodominant regions on β-lactoglobulin, which were also recognized by serum IgEs from cow's milk allergic children. Usage of our 'unlimited' source and well-defined pool of β-lactoglobulin-specific recombinant chuIgEs to sensitize huFcεRIα on RBL-2H3 cells showed to be a relevant and sensitive alternative for serum IgEs from cow's milk allergic patients to assess safety of whey-based non-allergic hydrolyzed formula.
CT colonography of colorectal polyps: a metaanalysis.
Sosna, Jacob; Morrin, Martina M; Kruskal, Jonathan B; Lavin, Philip T; Rosen, Max P; Raptopoulos, Vassilios
2003-12-01
For proper evaluation of the accuracy of CT colonography, prospective multiinstitutional trials would be ideal. Until these trials are available, data can be collectively analyzed. The purpose of this study is to use metaanalysis to assess the reported accuracy of CT colonography compared with conventional colonoscopy for detecting colorectal polyps. Articles comparing CT colonography and conventional colonoscopy were identified, and a standardized form was used to extract relevant study data. Fisher's exact test and the Mantel-Haenszel test were used for pooling of data. A 95% confidence interval (CI) was selected to determine sensitivity and specificity, and the Kruskal-Wallis exact test was used to identify trends relating to polyp size. Meta-analysis methods were used to test strength of results. Comparisons were made for the percentage of polyps detected grouped by size (> or = 10 mm, 6-9 mm, < or = 5 mm) and the percentage of patients identified who had polyps of the same size. Fourteen studies fulfilled all the study inclusion criteria and gave a total of 1,324 patients and 1,411 polyps. The pooled per-patient sensitivity for polyps 10 mm or larger was (sensitivity [95% CI]) 0.88 (0.84-0.93), for polyps 6-9 mm it was 0.84 (0.80-0.89), and for polyps 5 mm or smaller it was 0.65 (0.57-0.73). The pooled per-polyp sensitivity for polyps 10 mm or larger was 0.81 (0.76-0.85), for polyps 6-9 mm it was 0.62 (0.58-0.67), and for polyps 5 mm or smaller it was 0.43 (0.39-0.47). Sensitivity for detection of polyps increased as the polyp size increased (p < 0.00005). The pooled overall specificity for detection of polyps larger than 10 mm was 0.95 (0.94-0.97). The specificity and sensitivity of CT colonography are high for polyps larger than 10 mm.
Jia, Hui-Miao; Huang, Li-Feng; Zheng, Yue; Li, Wen-Xiong
2017-03-25
Tissue inhibitor of metalloproteinase-2 (TIMP-2) and insulin-like growth factor binding protein 7 (IGFBP7), inducers of G 1 cell cycle arrest, are two recently discovered good biomarkers for early diagnosis of acute kidney injury (AKI). To obtain a more robust performance measurement, the present meta-analysis was performed, pooling existing studies. Literature in the MEDLINE (via PubMed), Ovid, Embase, and Cochrane Library databases was systematically searched from inception to 12 October 2016. Studies that met the set inclusion and exclusion criteria were identified by two independent investigators. The diagnostic value of urinary [TIMP-2] × [IGFBP7] for AKI was evaluated by pooled sensitivity, specificity, likelihood ratio (LR), diagnostic odds ratio (DOR), and summary receiver operating characteristic (SROC) curve analyses. The causes of heterogeneity were explored by sensitivity and subgroup analyses. A total of nine published and eligible studies assessing 1886 cases were included in this meta-analysis. Early diagnostic value of urinary [TIMP-2] × [IGFBP7] for AKI was assessed using a random-effects model. Pooled sensitivity and specificity with corresponding 95% CIs were 0.83 (95% CI 0.79-0.87, heterogeneity I 2 = 68.8%) and 0.55 (95% CI 0.52-0.57, I 2 = 92.9%), respectively. Pooled positive LR, negative LR, and DOR were 2.37 (95% CI 1.87-2.99, I 2 = 82.6%), 0.30 (95% CI 0.21-0.41, I 2 = 43.4%), and 9.92 (95% CI 6.09-16.18, I 2 = 38.5%), respectively. The AUC estimated by SROC was 0.846 (SE 0.027) with a Q* value of 0.777 (SE 0.026). Sensitivity analysis indicated that one study significantly affected the stability of pooled results. Subgroup analysis showed that population setting and AKI threshold were the key factors causing heterogeneity in pooled sensitivity and specificity. On the basis of recent evidence, urinary [TIMP-2] × [IGFBP7] is an effective predictive factor of AKI. PROSPERO registration number: CRD42016051186 . Registered on 10 November 2016.
Accuracy of Raman spectroscopy in differentiating brain tumor from normal brain tissue.
Zhang, Jing; Fan, Yimeng; He, Min; Ma, Xuelei; Song, Yanlin; Liu, Ming; Xu, Jianguo
2017-05-30
Raman spectroscopy could be applied to distinguish tumor from normal tissues. This meta-analysis was conducted to assess the accuracy of Raman spectroscopy in differentiating brain tumor from normal brain tissue. PubMed and Embase were searched to identify suitable studies prior to Jan 1st, 2016. We estimated the pooled sensitivity, specificity, positive and negative likelihood ratios (LR), diagnostic odds ratio (DOR), and constructed summary receiver operating characteristics (SROC) curves to identity the accuracy of Raman spectroscopy in differentiating brain tumor from normal brain tissue. A total of six studies with 1951 spectra were included. For glioma, the pooled sensitivity and specificity of Raman spectroscopy were 0.96 (95% CI 0.94-0.97) and 0.99 (95% CI 0.98-0.99), respectively. The area under the curve (AUC) was 0.9831. For meningioma, the pooled sensitivity and specificity were 0.98 (95% CI 0.94-1.00) and 1.00 (95% CI 0.98-1.00), respectively. The AUC was 0.9955. This meta-analysis suggested that Raman spectroscopy could be an effective and accurate tool for differentiating glioma and meningioma from normal brain tissue, which would help us both avoid removal of normal tissue and minimize the volume of residual tumor.
Ha, Hong Ku; Koo, Phillip J; Kim, Seong-Jang
2018-05-30
We aimed to assess the diagnostic accuracy of F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for preoperative lymph node (LN) staging in newly diagnosed bladder cancer (BC) patients through a systematic review and meta-analysis. MEDLINE, Embase, and the Cochrane Library database, from the earliest available date of indexing through June 30, 2017, were searched for studies evaluating the diagnostic performance of F-18 FDG PET/CT for preoperative LN staging in newly diagnosed BC. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR+ and LR-), and constructed summary receiver operating characteristic curves. Across 14 studies (785 patients), the pooled sensitivity was 0.57 (95% CI: 0.49-0.64) and the pooled specificity was 0.92 (95% CI: 0.87-0.95). The LR syntheses gave an overall LR+ of 7.4 (95% CI: 4.4-12.3) and an LR- of 0.47 (95% CI: 0.39-0.56). The pooled diagnostic odds ratio was 16 (95% CI: 9-28). F-18 FDG PET/CT shows a low sensitivity and high specificity for the detection of metastatic LNs in patients with newly diagnosed BC. © 2018 S. Karger AG, Basel.
Santamaría, Erika; Ponce, Nubia; Puerta, Concepción; Ferro, Cristina
2005-06-01
The applicability of the polymerase chain reaction (PCR) was evaluated for the detection and identification of parasites in sand fly vectors and thereby precluding the necessity of dissecting them. DNA was extracted from individual, laboratory infected sand flies, and subjected to PCR amplification using specific B1 and B2 primers for parasites of the Leishmania (Viannia) subgenus. The sensitivity and specificity of the PCR primers were defined by means of serial dilutions of a Leishmania culture. Pooled samples of 1 to 5 sandflies were examined in association with the parasite dilutions to determine the point at which sensitivity became reduced. Experimentally infected sand flies were used to compare the sensitivity of the PCR with sand fly dissection and searching for flagellated parasites by microscopic examination. As few as a single parasite was detected, and the sensitivity remained unaltered up to 3 female sand flies per pool. Detection rates were 33% for the traditional technique and 33.3% for PCR. The B1 and B2 primers were confirmed as specific for Leishmania (Viannia) parasites. The demonstrably high sensitivity and specificity of PCR warrant the use of PCR in assessing natural infection rates of Leishmania (Viannia) in field populations of sand fly vectors.
Xiong, Yi-Quan; Ma, Shu-Juan; Zhou, Jun-Hua; Zhong, Xue-Shan; Chen, Qing
2016-06-01
Barrett's esophagus (BE) is considered the most important risk factor for development of esophageal adenocarcinoma. Confocal laser endomicroscopy (CLE) is a recently developed technique used to diagnose neoplasia in BE. This meta-analysis was performed to assess the accuracy of CLE for diagnosis of neoplasia in BE. We searched EMBASE, PubMed, Cochrane Library, and Web of Science to identify relevant studies for all articles published up to June 27, 2015 in English. The quality of included studies was assessed using QUADAS-2. Per-patient and per-lesion pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio with 95% confidence intervals (CIs) were calculated. In total, 14 studies were included in the final analysis, covering 789 patients with 4047 lesions. Seven studies were included in the per-patient analysis. Pooled sensitivity and specificity were 89% (95% CI: 0.82-0.94) and 83% (95% CI: 0.78-0.86), respectively. Ten studies were included in the per-lesion analysis. Compared with the PP analysis, the corresponding pooled sensitivity declined to 77% (95% CI: 0.73-0.81) and specificity increased to 89% (95% CI: 0.87-0.90). Subgroup analysis showed that probe-based CLE (pCLE) was superior to endoscope-based CLE (eCLE) in pooled specificity [91.4% (95% CI: 89.7-92.9) vs 86.1% (95% CI: 84.3-87.8)] and AUC for the sROC (0.885 vs 0.762). Confocal laser endomicroscopy is a valid method to accurately differentiate neoplasms from non-neoplasms in BE. It can be applied to BE surveillance and early diagnosis of esophageal adenocarcinoma. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Kim, Hae Young; Park, Ji Hoon; Lee, Yoon Jin; Lee, Sung Soo; Jeon, Jong-June; Lee, Kyoung Ho
2018-04-01
Purpose To perform a systematic review and meta-analysis to identify computed tomographic (CT) features for differentiating complicated appendicitis in patients suspected of having appendicitis and to summarize their diagnostic accuracy. Materials and Methods Studies on diagnostic accuracy of CT features for differentiating complicated appendicitis (perforated or gangrenous appendicitis) in patients suspected of having appendicitis were searched in Ovid-MEDLINE, EMBASE, and the Cochrane Library. Overlapping descriptors used in different studies to denote the same image finding were subsumed under a single CT feature. Pooled diagnostic accuracy of the CT features was calculated by using a bivariate random effects model. CT features with pooled diagnostic odds ratios with 95% confidence intervals not including 1 were considered as informative. Results Twenty-three studies were included, and 184 overlapping descriptors for various CT findings were subsumed under 14 features. Of these, 10 features were informative for complicated appendicitis. There was a general tendency for these features to show relatively high specificity but low sensitivity. Extraluminal appendicolith, abscess, appendiceal wall enhancement defect, extraluminal air, ileus, periappendiceal fluid collection, ascites, intraluminal air, and intraluminal appendicolith showed pooled specificity greater than 70% (range, 74%-100%), but sensitivity was limited (range, 14%-59%). Periappendiceal fat stranding was the only feature that showed high sensitivity (94%; 95% confidence interval: 86%, 98%) but low specificity (40%; 95% confidence interval, 23%, 60%). Conclusion Ten informative CT features for differentiating complicated appendicitis were identified in this study, nine of which showed high specificity, but low sensitivity. © RSNA, 2017 Online supplemental material is available for this article.
Diagnostic accuracy and reproducibility of the Ottawa Knee Rule vs the Pittsburgh Decision Rule.
Cheung, Tung C; Tank, Yeliz; Breederveld, Roelf S; Tuinebreijer, Wim E; de Lange-de Klerk, Elly S M; Derksen, Robert J
2013-04-01
The aim of this present study was to compare the diagnostic accuracy and reproducibility of 2 clinical decision rules (the Ottawa Knee Rules [OKR] and Pittsburgh Decision Rules [PDR]) developed for selective use of x-rays in the evaluation of isolated knee trauma. Application of a decision rule leads to a more efficient evaluation of knee injuries and a reduction in health care costs. The diagnostic accuracy and reproducibility are compared in this study. A cross-sectional interobserver study was conducted in the emergency department of an urban teaching hospital from October 2008 to July 2009. Two observer groups collected data on standardized case-report forms: emergency medicine residents and surgical residents. Standard knee radiographs were performed in each patient. Participants were patients 18 years and older with isolated knee injuries. Pooled sensitivity and specificity were compared using χ(2) statistics, and interobserver agreement was calculated by using κ statistics. Ninety injuries were assessed. Seven injuries concerned fractures (7.8%). For the OKR, the pooled sensitivity and specificity were 0.86 (95% confidence interval [CI], 0.57-0.96) and 0.27 (95% CI, 0.21-0.35), respectively. The PDR had a pooled sensitivity and specificity of 0.86 (95% CI, 0.57-0.96) and 0.51 (95% CI, 0.44-0.59). The PDR was significantly (P = .002) more specific. The κ values for the OKR and PDR were 0.51 (95% CI, 0.32-0.71) and 0.71 (95% CI, 0.57-0.86), respectively. The PDR was found to be more specific than the OKR, with equal sensitivity. Interobserver agreement was moderate for the OKR and substantial for the PDR. Copyright © 2013 Elsevier Inc. All rights reserved.
Parente, Diane M; Cunha, Cheston B; Mylonakis, Eleftherios; Timbrook, Tristan T
2018-01-11
Recent literature has highlighted MRSA nasal screening as a possible antimicrobial stewardship program (ASP) tool for avoiding unnecessary empiric MRSA therapy for pneumonia, yet current guidelines recommend MRSA therapy based on risk factors. The objective of this meta-analysis was to evaluate the diagnostic value of MRSA nasal screening in MRSA pneumonia. Pubmed and EMBASE were searched from inception to November 2016 for English studies evaluating MRSA nasal screening and development of MRSA pneumonia. Data analysis was performed using a bivariate random-effects model to estimate pooled sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values. Twenty-two studies, comprising of 5,163 patients met our inclusion criteria. Pooled sensitivity and specificity of MRSA nares screen for all MRSA pneumonia types was 70.9% and 90.3%, respectively. With a 10% prevalence of potential MRSA pneumonia, the calculated PPV was 44.8% while the NPV was 96.5%. The pooled sensitivity and specificity for MRSA community-acquired pneumonia (CAP) and healthcare-associated pneumonia (HCAP) were at 85% and 92.1%, respectively. For CAP and HCAP both the PPV and NPV increased to 56.8% and 98.1%, respectively. In comparison, for MRSA ventilated-associated pneumonia (VAP), the sensitivity, specificity, PPV, NPV was 40.3%, 93.7%, 35.7%, and 94.8%, respectively. Nares screening for MRSA had a high specificity and NPV for ruling out MRSA pneumonia, particularly in cases of CAP/HCAP. Based on the NPV, utilization of MRSA nares screening is a valuable tool for AMS to streamline empiric antibiotic therapy, especially among patients with pneu. © The Author(s) 2018. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
Banal, F; Dougados, M; Combescure, C; Gossec, L
2009-07-01
To evaluate the ability of the widely used ACR set of criteria (both list and tree format) to diagnose RA compared with expert opinion according to disease duration. A systematic literature review was conducted in PubMed and Embase databases. All articles reporting the prevalence of RA according to ACR criteria and expert opinion in cohorts of early (<1 year duration) or established (>1 year) arthritis were analysed to calculate the sensitivity and specificity of ACR 1987 criteria against the "gold standard" (expert opinion). A meta-analysis using a summary receiver operating characteristic (SROC) curve was performed and pooled sensitivity and specificity were calculated with confidence intervals. Of 138 publications initially identified, 19 were analysable (total 7438 patients, 3883 RA). In early arthritis, pooled sensitivity and specificity of the ACR set of criteria were 77% (68% to 84%) and 77% (68% to 84%) in the list format versus 80% (72% to 88%) and 33% (24% to 43%) in the tree format. In established arthritis, sensitivity and specificity were respectively 79% (71% to 85%) and 90% (84% to 94%) versus 80% (71% to 85%) and 93% (86% to 97%). The SROC meta-analysis confirmed the statistically significant differences, suggesting that diagnostic performances of ACR list criteria are better in established arthritis. The specificity of ACR 1987 criteria in early RA is low, and these criteria should not be used as diagnostic tools. Sensitivity and specificity in established RA are higher, which reflects their use as classification criteria gold standard.
Determination and impact of surface radiative processes for TOGA COARE
NASA Technical Reports Server (NTRS)
Curry, Judith A.; Ackerman, Thomas; Rossow, William B.; Webster, Peter J.
1991-01-01
Experiments using atmospheric general circulation models have shown that the atmospheric circulation is very sensitive to small changes in sea surface temperature in the tropical western Pacific Ocean warm pool region. The mutual sensitivity of the ocean and the atmosphere in the warm pool region places stringent requirements on models of the coupled ocean atmosphere system. At present, the situation is such that diagnostic studies using available data sets have been unable to balance the surface energy budget in the warm pool region to better than 50 to 80 W/sq m. The Tropical Ocean Global Atmosphere (TOGA) Coupled Ocean Atmosphere Response Experiment (COARE) is an observation and modelling program that aims specifically at the elucidation of the physical process which determine the mean and transient state of the warm pool region and the manner in which the warm pool interacts with the global ocean and atmosphere. This project focuses on one very important aspect of the ocean atmosphere interface component of TOGA COARE, namely the temporal and spatial variability of surface radiative fluxes in the warm pool region.
Luo, Mingxu; Lv, You; Guo, Xiuyu; Song, Hongmei; Su, Guoqiang; Chen, Bo
2017-08-01
Multidetector computed tomography (MDCT) exhibited wide ranges of sensitivities and specificities for lymph node assessment of gastric cancer (GC) in several individual studies. This present meta-analysis was carried out to evaluate the value of MDCT in diagnosis of preoperative lymph node metastasis (LNM) and to explore the impact factors that might explain the heterogeneity of its diagnostic accuracy in GC. A comprehensive search was conducted to collect all the relevant studies about the value of MDCT in assessing LNM of GC within the PubMed, Cochrane library and Embase databases up to Feb 2, 2016. Two investigators independently screened the studies, extracted data, and evaluated the quality of included studies. The sensitivity, specificity, and area under ROC curve (AUC) were pooled to estimate the overall accuracy of MDCT. Meta-regression and subgroup analysis were carried out to identify the possible factors influencing the heterogeneity of the accuracy. A total of 27 studies with 6519 subjects were finally included. Overall, the pooled sensitivity, specificity, and AUC were 0.67 (95% CI: 0.56-0.77), 0.86 (95% CI: 0.81-0.90), and 0.86 (95% CI: 0.83-0.89), respectively. Meta-regression revealed that MDCT section thickness, proportion of serosal invasion, and publication year were the main significant impact factors in sensitivity, and MDCT section thickness, multiplanar reformation (MPR), and reference standard were the main significant impact factors in specificity. After the included studies were divided into 2 groups (Group A: studies with proportion of serosa-invasive GC subjects ≥50%; Group B: studies with proportion of serosa-invasive GC subjects <50%), the pooled sensitivity in Group A was significantly higher than in Group B (0.84 [95% CI: 0.75-0.90] vs 0.55 [95% CI: 0.41-0.68], P < .01). For early gastric cancer (EGC), the pooled sensitivity, specificity, and AUC were 0.34 (95% CI: 0.15-0.61), 0.91 (95% CI: 0.84-0.95), and 0.83 (95% CI: 0.80-0.86), respectively. To summarize, MDCT tends to be adequate to assess preoperative LNM in serosa-invasive GC, but insufficient for non-serosa-invasive GC (particularly for EGC) owing to its low sensitivity. Proportion of serosa-invasive GC subjects, MDCT section thickness, MPR, and reference standard are the main factors influencing its diagnostic accuracy.
Woo, Sungmin; Suh, Chong Hyun; Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup
2017-11-01
The purpose of this article is to systematically review and perform a meta-analysis of the diagnostic performance of CT for diagnosis of fat-poor angiomyolipoma (AML) in patients with renal masses. MEDLINE and EMBASE were systematically searched up to February 2, 2017. We included diagnostic accuracy studies that used CT for diagnosis of fat-poor AML in patients with renal masses, using pathologic examination as the reference standard. Two independent reviewers assessed the methodologic quality using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity of included studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Sensitivity analyses using several clinically relevant covariates were performed to explore heterogeneity. Fifteen studies (2258 patients) were included. Pooled sensitivity and specificity were 0.67 (95% CI, 0.48-0.81) and 0.97 (95% CI, 0.89-0.99), respectively. Substantial and considerable heterogeneity was present with regard to sensitivity and specificity (I 2 = 91.21% and 78.53%, respectively). At sensitivity analyses, the specificity estimates were comparable and consistently high across all subgroups (0.93-1.00), but sensitivity estimates showed significant variation (0.14-0.82). Studies using pixel distribution analysis (n = 3) showed substantially lower sensitivity estimates (0.14; 95% CI, 0.04-0.40) compared with the remaining 12 studies (0.81; 95% CI, 0.76-0.85). CT shows moderate sensitivity and excellent specificity for diagnosis of fat-poor AML in patients with renal masses. When methods other than pixel distribution analysis are used, better sensitivity can be achieved.
Galel, Susan A; Simon, Toby L; Williamson, Phillip C; AuBuchon, James P; Waxman, Dan A; Erickson, Yasuko; Bertuzis, Rasa; Duncan, John R; Malhotra, Khushbeer; Vaks, Jeffrey; Huynh, Nancy; Pate, Lisa Lee
2018-03-01
Use of nucleic acid testing (NAT) in donor infectious disease screening improves transfusion safety. Advances in NAT technology include improvements in assay sensitivity and system automation, and real-time viral target discrimination in multiplex assays. This article describes the sensitivity and specificity of cobas MPX, a multiplex assay for detection of human immunodeficiency virus (HIV)-1 Group M, HIV-2 and HIV-1 Group O RNA, HCV RNA, and HBV DNA, for use on the cobas 6800/8800 Systems. The specificity of cobas MPX was evaluated in samples from donors of blood and source plasma in the United States. Analytic sensitivity was determined with reference standards. Infectious window periods (WPs) before NAT detectability were calculated for current donor screening assays. The specificity of cobas MPX was 99.946% (99.883%-99.980%) in 11,203 blood donor samples tested individually (IDT), 100% (99.994%-100%) in 63,012 donor samples tested in pools of 6, and 99.994% (99.988%-99.998%) in 108,306 source plasma donations tested in pools of 96. Seven HCV NAT-yield donations and one seronegative occult HBV infection were detected. Ninety-five percent and 50% detection limits in plasma (IU/mL) were 25.7 and 3.8 for HIV-1M, 7.0 and 1.3 for HCV, and 1.4 and 0.3 for HBV. The HBV WP was 1 to 4 days shorter than other donor screening assays by IDT. cobas MPX demonstrated high specificity in blood and source plasma donations tested individually and in pools. High sensitivity, in particular for HBV, shortens the WP and may enhance detection of occult HBV. © 2017 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.
Gismervik, Sigmund Ø; Drogset, Jon O; Granviken, Fredrik; Rø, Magne; Leivseth, Gunnar
2017-01-25
Physical examination tests of the shoulder (PETS) are clinical examination maneuvers designed to aid the assessment of shoulder complaints. Despite more than 180 PETS described in the literature, evidence of their validity and usefulness in diagnosing the shoulder is questioned. This meta-analysis aims to use diagnostic odds ratio (DOR) to evaluate how much PETS shift overall probability and to rank the test performance of single PETS in order to aid the clinician's choice of which tests to use. This study adheres to the principles outlined in the Cochrane guidelines and the PRISMA statement. A fixed effect model was used to assess the overall diagnostic validity of PETS by pooling DOR for different PETS with similar biomechanical rationale when possible. Single PETS were assessed and ranked by DOR. Clinical performance was assessed by sensitivity, specificity, accuracy and likelihood ratio. Six thousand nine-hundred abstracts and 202 full-text articles were assessed for eligibility; 20 articles were eligible and data from 11 articles could be included in the meta-analysis. All PETS for SLAP (superior labral anterior posterior) lesions pooled gave a DOR of 1.38 [1.13, 1.69]. The Supraspinatus test for any full thickness rotator cuff tear obtained the highest DOR of 9.24 (sensitivity was 0.74, specificity 0.77). Compression-Rotation test obtained the highest DOR (6.36) among single PETS for SLAP lesions (sensitivity 0.43, specificity 0.89) and Hawkins test obtained the highest DOR (2.86) for impingement syndrome (sensitivity 0.58, specificity 0.67). No single PETS showed superior clinical test performance. The clinical performance of single PETS is limited. However, when the different PETS for SLAP lesions were pooled, we found a statistical significant change in post-test probability indicating an overall statistical validity. We suggest that clinicians choose their PETS among those with the highest pooled DOR and to assess validity to their own specific clinical settings, review the inclusion criteria of the included primary studies. We further propose that future studies on the validity of PETS use randomized research designs rather than the accuracy design relying less on well-established gold standard reference tests and efficient treatment options.
Zhang, Li; Tang, Min; Chen, Sipan; Lei, Xiaoyan; Zhang, Xiaoling; Huan, Yi
2017-12-01
This meta-analysis was undertaken to review the diagnostic accuracy of PI-RADS V2 for prostate cancer (PCa) detection with multiparametric MR (mp-MR). A comprehensive literature search of electronic databases was performed by two observers independently. Inclusion criteria were original research using the PI-RADS V2 system in reporting prostate MRI. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Data necessary to complete 2 × 2 contingency tables were obtained from the included studies. Thirteen studies (2,049 patients) were analysed. This is an initial meta-analysis of PI-RADs V2 and the overall diagnostic accuracy in diagnosing PCa was as follows: pooled sensitivity, 0.85 (0.78-0.91); pooled specificity, 0.71 (0.60-0.80); pooled positive likelihood ratio (LR+), 2.92 (2.09-4.09); pooled negative likelihood ratio (LR-), 0.21 (0.14-0.31); pooled diagnostic odds ratio (DOR), 14.08 (7.93-25.01), respectively. Positive predictive values ranged from 0.54 to 0.97 and negative predictive values ranged from 0.26 to 0.92. Currently available evidence indicates that PI-RADS V2 appears to have good diagnostic accuracy in patients with PCa lesions with high sensitivity and moderate specificity. However, no recommendation regarding the best threshold can be provided because of heterogeneity. • PI-RADS V2 shows good diagnostic accuracy for PCa detection. • Initially pooled specificity of PI-RADS v2 remains moderate. • PCa detection is increased by experienced radiologists. • There is currently a high heterogeneity in prostate diagnostics with MRI.
Buelens-Sleumer, Laura S.; Cox, Linda; den Hartog, Marcel; de Jong, Niels; Teshima, Reiko; Garssen, Johan; Boon, Louis; Knippels, Léon M. J.
2014-01-01
Background Cow’s milk-derived whey hydrolysates are nutritional substitutes for allergic infants. Safety or residual allergenicity assessment of these whey hydrolysates is crucial. Currently, rat basophilic leukemia RBL-2H3 cells expressing the human IgE receptor α-chain (huFcεRIα-RBL-2H3), sensitized with serum IgE from cow’s milk allergic children, are being employed to assess in vitro residual allergenicity of these whey hydrolysates. However, limited availability and inter-lot variation of these allergic sera impede standardization of whey hydrolysate safety testing in degranulation assays. Objective An oligoclonal pool of chimeric human (chu)IgE antibodies against bovine β-lactoglobulin (a major allergen in whey) was generated to increase sensitivity, specificity, and reproducibility of existing degranulation assays. Methods Mice were immunized with bovine β-lactoglobulin, and subsequently the variable domains of dissimilar anti-β-lactoglobulin mouse IgG antibodies were cloned and sequenced. Six chimeric antibodies were generated comprising mouse variable domains and human constant IgE/κ domains. Results After sensitization with this pool of anti-β-lactoglobulin chuIgEs, huFcεRIα-expressing RBL-2H3 cells demonstrated degranulation upon cross-linking with whey, native 18 kDa β-lactoglobulin, and 5–10 kDa whey hydrolysates, whereas a 3 kDa whey hydrolysate and cow’s milk powder (mainly casein) showed no degranulation. In parallel, allergic serum IgEs were less sensitive. In addition, our pool anti-β-lactoglobulin chuIgEs recognized multiple allergenic immunodominant regions on β-lactoglobulin, which were also recognized by serum IgEs from cow’s milk allergic children. Conclusion Usage of our ‘unlimited’ source and well-defined pool of β-lactoglobulin-specific recombinant chuIgEs to sensitize huFcεRIα on RBL-2H3 cells showed to be a relevant and sensitive alternative for serum IgEs from cow’s milk allergic patients to assess safety of whey-based non-allergic hydrolyzed formula. PMID:25153680
Rustagi, Tarun; Njei, Basile
2014-08-01
This study aimed to perform a structured meta-analysis of all eligible studies to assess the overall diagnostic use of magnetic resonance cholangiopancreatography (MRCP) alone or with secretin enhancement (secretin-enhanced MRCP [S-MRCP]) in the detection of pancreas divisum. Two authors independently performed a comprehensive search of PubMed, MEDLINE, and the Cochrane Library from inception to September 2013. Studies were included if they allowed construction of 2 × 2 contingency tables of MRCP and/or S-MRCP compared with criterion standard. DerSimonian-Laird random effect models were used to estimate the pooled sensitivity, specificity, specificity, and quantitative receiver operating characteristics. Of 51 citations, 10 studies with 1474 patients were included. Secretin-enhanced MRCP had a higher overall diagnostic performance than MRCP (S-MRCP: pooled sensitivity, 86% [95% confidence interval (CI), 77%-93%]; specificity, 97% [95% CI, 94%-99%]; and area under the curve, 0.93 ± 0.056 compared with MRCP: sensitivity, 52% [95% CI, 45%-59%]; specificity, 97% [95% CI, 94%-99%]; and area under the curve, 0.76 ± 0.104). Pooled diagnostic odds ratios were 72.19 (95% CI, 5.66-938.8) and 23.39 (95% CI, 7.93-69.02) for S-MRCP and MRCP, respectively. Visual inspection of the funnel plot showed low potential for publication bias. Secretin-enhanced MRCP has a much higher diagnostic accuracy than MRCP and should be preferred for diagnosis of pancreas divisum.
Zhang, Aimi; Li, Panli; Liu, Qiufang; Song, Shaoli
2017-01-01
This study aimed to evaluate the diagnostic role of breast-specific gamma camera imaging (BSGI) with technetium-99m-methoxy isobutyl isonitrile ( 99m Tc-MIBI) and magnetic resonance imaging (MRI) in patients with breast cancer through a meta-analysis. Three reviewers searched articles published in medical journals before June 2016 in MEDLINE, EMBASE and Springer Databases; the references listed in original articles were also retrieved. We used the quality assessment of diagnostic accuracy studies (QUADAS) tool to assess the quality of the included studies. Heterogeneity, pooled sensitivity and specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio (DOR) and summary receiver operating characteristic (SROC) curves were calculated by Meta-DiSc software to estimate the diagnostic performance of BSGI and MRI. Ten studies with 517 patients were included after meeting the inclusion criteria. We did a subgroup analysis of the same data type. The pooled sensitivities of BSGI and MRI were: 0.84 (95% CI, 0.79-0.88) and 0.89 (95% CI, 0.84-0.92) respectively, and the pooled specificities of BSGI and MRI were: 0.82 (95% CI, 0.74-0.88) and 0.39 (95% CI, 0.30-0.49) respectively. The areas under the SROC curve of BSGI and MRI were 0.93 and 0.72 respectively. The results of our meta-analysis indicated that compared with MRI, BSGI has similar sensitivity, higher specificity, better diagnostic performance, and can be widely used in clinical practice.
Mallorie, Amy; Goldring, James; Patel, Anant; Lim, Eric; Wagner, Thomas
2017-08-01
Lymph node involvement in non-small-cell lung cancer (NSCLC) is a major factor in determining management and prognosis. We aimed to evaluate the accuracy of fluorine-18-fluorodeoxyglucose-PET/computed tomography (CT) for the assessment of nodal involvement in patients with NSCLC. In this retrospective study, we included 61 patients with suspected or confirmed resectable NSCLC over a 2-year period from April 2013 to April 2015. 221 nodes with pathological staging from surgery or endobronchial ultrasound-guided transbronchial needle aspiration were assessed using a nodal station-based analysis with original clinical reports and three different cut-offs: mediastinal blood pool (MBP), liver background and tumour standardized uptake value maximal (SUVmax)/2. Using nodal station-based analysis for activity more than tumour SUVmax/2, the sensitivity was 45%, the specificity was 89% and the negative predictive value (NPV) was 87%. For activity more than MBP, the sensitivity was 93%, the specificity was 72% and NPV was 98%. For activity more than liver background, the sensitivity was 83%, the specificity was 84% and NPV was 96%. Using a nodal staging-based analysis for accuracy at detecting N2/3 disease, for activity more than tumour SUVmax/2, the sensitivity was 59%, the specificity was 85% and NPV was 80%. For activity more than MBP, the sensitivity was 95%, the specificity was 61% and NPV was 96%. For activity more than liver background, the sensitivity was 86%, the specificity was 81% and NPV was 92%. Receiver-operating characteristic analysis showed the optimal nodal SUVmax to be more than 6.4 with a sensitivity of 45% and a specificity of 95%, with an area under the curve of 0.85. Activity more than MBP was the most sensitive cut-off with the highest sensitivity and NPV. Activity more than primary tumour SUVmax/2 was the most specific cut-off. Nodal SUVmax more than 6.4 has a high specificity of 95%.
Use of point-of-care ultrasound in long bone fractures: a systematic review and meta-analysis.
Chartier, Lucas B; Bosco, Laura; Lapointe-Shaw, Lauren; Chenkin, Jordan
2017-03-01
Long bone fractures (LBFs) are among the most frequent traumatic injuries seen in emergency departments. Reduction and immobilization is the most common form of treatment for displaced fractures. Point-of-care ultrasound (PoCUS) is a promising technique for diagnosing LBFs and assessing the success of reduction attempts. This article offers a comprehensive review of the use of PoCUS for the diagnosis and reduction of LBFs. Data source MEDLINE and EMBASE databases were searched through July 19, 2015. Study selection We included prospective studies that assessed test characteristics of PoCUS in 1) the diagnosis or 2) the reduction of LBFs. The methodological quality of the included studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Data extraction Thirty studies met inclusion criteria (n=3,506; overall fracture rate 48.0%). Test characteristics of PoCUS for the diagnosis of LBFs were as follows: sensitivity 64.7%-100%, specificity 79.2%-100%, positive likelihood ratio (LR) 3.11-infinity, and negative LR zero-0.45. Sensitivity and specificity for the adequate reduction of LBFs with PoCUS were 94%-100% and 56%-100%, respectively. PoCUS diagnosis of pediatric forearm fractures in 10 studies showed a pooled sensitivity of 93.1% (95% confidence interval [CI], 87.2%-96.4%) and specificity of 92.9% (95% CI, 86.6%-96.4%), and PoCUS diagnosis of adult ankle fractures in four studies showed a pooled sensitivity of 89.5% (95% CI, 77.0%-95.6%) and specificity of 94.2% (95% CI, 86.1%-97.7%). PoCUS demonstrates good diagnostic accuracy in all LBFs studied, especially in pooled results of diagnosis of pediatric forearm and adult ankle fractures. PoCUS is an appropriate adjunct to plain radiographs for LBFs.
Zaer, F; Metz, S; Scornik, J C
1997-01-15
The enzyme-linked immunosorbent assay (ELISA) using HLA class I molecules purified from pooled platelets has the potential to detect HLA antibodies with increased efficiency without sacrificing sensitivity or specificity. This test, which was originally developed in our institution, has been independently validated by recent studies and is now commercially available. We now present evidence of its usefulness as a routine HLA antibody screening test for renal transplant patients. A total of 515 patients were tested monthly by ELISA (13.9 tests/patient) and by antiglobulin-enhanced panel reactivity (6.3 tests/patient). In patients found to be unsensitized, the incidence of false-positive results was less for ELISA than for the panel studies. In patients who were highly sensitized, both tests performed equally well, whereas discordant results were registered mainly in cases of mild sensitization. Because 66% of our patients were not sensitized, the ELISA was effective in reducing the number of more involved tests aimed at characterizing the antibodies. These results provide a foundation to use the pooled platelet HLA ELISA on a routine basis for HLA antibody screening.
Psifidi, Androniki; Dovas, Chrysostomos; Banos, Georgios
2011-01-19
Single nucleotide polymorphisms (SNP) have proven to be powerful genetic markers for genetic applications in medicine, life science and agriculture. A variety of methods exist for SNP detection but few can quantify SNP frequencies when the mutated DNA molecules correspond to a small fraction of the wild-type DNA. Furthermore, there is no generally accepted gold standard for SNP quantification, and, in general, currently applied methods give inconsistent results in selected cohorts. In the present study we sought to develop a novel method for accurate detection and quantification of SNP in DNA pooled samples. The development and evaluation of a novel Ligase Chain Reaction (LCR) protocol that uses a DNA-specific fluorescent dye to allow quantitative real-time analysis is described. Different reaction components and thermocycling parameters affecting the efficiency and specificity of LCR were examined. Several protocols, including gap-LCR modifications, were evaluated using plasmid standard and genomic DNA pools. A protocol of choice was identified and applied for the quantification of a polymorphism at codon 136 of the ovine PRNP gene that is associated with susceptibility to a transmissible spongiform encephalopathy in sheep. The real-time LCR protocol developed in the present study showed high sensitivity, accuracy, reproducibility and a wide dynamic range of SNP quantification in different DNA pools. The limits of detection and quantification of SNP frequencies were 0.085% and 0.35%, respectively. The proposed real-time LCR protocol is applicable when sensitive detection and accurate quantification of low copy number mutations in DNA pools is needed. Examples include oncogenes and tumour suppressor genes, infectious diseases, pathogenic bacteria, fungal species, viral mutants, drug resistance resulting from point mutations, and genetically modified organisms in food.
Psifidi, Androniki; Dovas, Chrysostomos; Banos, Georgios
2011-01-01
Background Single nucleotide polymorphisms (SNP) have proven to be powerful genetic markers for genetic applications in medicine, life science and agriculture. A variety of methods exist for SNP detection but few can quantify SNP frequencies when the mutated DNA molecules correspond to a small fraction of the wild-type DNA. Furthermore, there is no generally accepted gold standard for SNP quantification, and, in general, currently applied methods give inconsistent results in selected cohorts. In the present study we sought to develop a novel method for accurate detection and quantification of SNP in DNA pooled samples. Methods The development and evaluation of a novel Ligase Chain Reaction (LCR) protocol that uses a DNA-specific fluorescent dye to allow quantitative real-time analysis is described. Different reaction components and thermocycling parameters affecting the efficiency and specificity of LCR were examined. Several protocols, including gap-LCR modifications, were evaluated using plasmid standard and genomic DNA pools. A protocol of choice was identified and applied for the quantification of a polymorphism at codon 136 of the ovine PRNP gene that is associated with susceptibility to a transmissible spongiform encephalopathy in sheep. Conclusions The real-time LCR protocol developed in the present study showed high sensitivity, accuracy, reproducibility and a wide dynamic range of SNP quantification in different DNA pools. The limits of detection and quantification of SNP frequencies were 0.085% and 0.35%, respectively. Significance The proposed real-time LCR protocol is applicable when sensitive detection and accurate quantification of low copy number mutations in DNA pools is needed. Examples include oncogenes and tumour suppressor genes, infectious diseases, pathogenic bacteria, fungal species, viral mutants, drug resistance resulting from point mutations, and genetically modified organisms in food. PMID:21283808
Lo, Nathan C; Coulibaly, Jean T; Bendavid, Eran; N'Goran, Eliézer K; Utzinger, Jürg; Keiser, Jennifer; Bogoch, Isaac I; Andrews, Jason R
2016-08-01
A key epidemiologic feature of schistosomiasis is its focal distribution, which has important implications for the spatial targeting of preventive chemotherapy programs. We evaluated the diagnostic accuracy of a urine pooling strategy using a point-of-care circulating cathodic antigen (POC-CCA) cassette test for detection of Schistosoma mansoni, and employed simulation modeling to test the classification accuracy and efficiency of this strategy in determining where preventive chemotherapy is needed in low-endemicity settings. We performed a cross-sectional study involving 114 children aged 6-15 years in six neighborhoods in Azaguié Ahoua, south Côte d'Ivoire to characterize the sensitivity and specificity of the POC-CCA cassette test with urine samples that were tested individually and in pools of 4, 8, and 12. We used a Bayesian latent class model to estimate test characteristics for individual POC-CCA and quadruplicate Kato-Katz thick smears on stool samples. We then developed a microsimulation model and used lot quality assurance sampling to test the performance, number of tests, and total cost per school for each pooled testing strategy to predict the binary need for school-based preventive chemotherapy using a 10% prevalence threshold for treatment. The sensitivity of the urine pooling strategy for S. mansoni diagnosis using pool sizes of 4, 8, and 12 was 85.9%, 79.5%, and 65.4%, respectively, when POC-CCA trace results were considered positive, and 61.5%, 47.4%, and 30.8% when POC-CCA trace results were considered negative. The modeled specificity ranged from 94.0-97.7% for the urine pooling strategies (when POC-CCA trace results were considered negative). The urine pooling strategy, regardless of the pool size, gave comparable and often superior classification performance to stool microscopy for the same number of tests. The urine pooling strategy with a pool size of 4 reduced the number of tests and total cost compared to classical stool microscopy. This study introduces a method for rapid and efficient S. mansoni prevalence estimation through examining pooled urine samples with POC-CCA as an alternative to widely used stool microscopy.
Coulibaly, Jean T.; Bendavid, Eran; N’Goran, Eliézer K.; Utzinger, Jürg; Keiser, Jennifer; Bogoch, Isaac I.; Andrews, Jason R.
2016-01-01
Background A key epidemiologic feature of schistosomiasis is its focal distribution, which has important implications for the spatial targeting of preventive chemotherapy programs. We evaluated the diagnostic accuracy of a urine pooling strategy using a point-of-care circulating cathodic antigen (POC-CCA) cassette test for detection of Schistosoma mansoni, and employed simulation modeling to test the classification accuracy and efficiency of this strategy in determining where preventive chemotherapy is needed in low-endemicity settings. Methodology We performed a cross-sectional study involving 114 children aged 6–15 years in six neighborhoods in Azaguié Ahoua, south Côte d’Ivoire to characterize the sensitivity and specificity of the POC-CCA cassette test with urine samples that were tested individually and in pools of 4, 8, and 12. We used a Bayesian latent class model to estimate test characteristics for individual POC-CCA and quadruplicate Kato-Katz thick smears on stool samples. We then developed a microsimulation model and used lot quality assurance sampling to test the performance, number of tests, and total cost per school for each pooled testing strategy to predict the binary need for school-based preventive chemotherapy using a 10% prevalence threshold for treatment. Principal Findings The sensitivity of the urine pooling strategy for S. mansoni diagnosis using pool sizes of 4, 8, and 12 was 85.9%, 79.5%, and 65.4%, respectively, when POC-CCA trace results were considered positive, and 61.5%, 47.4%, and 30.8% when POC-CCA trace results were considered negative. The modeled specificity ranged from 94.0–97.7% for the urine pooling strategies (when POC-CCA trace results were considered negative). The urine pooling strategy, regardless of the pool size, gave comparable and often superior classification performance to stool microscopy for the same number of tests. The urine pooling strategy with a pool size of 4 reduced the number of tests and total cost compared to classical stool microscopy. Conclusions/Significance This study introduces a method for rapid and efficient S. mansoni prevalence estimation through examining pooled urine samples with POC-CCA as an alternative to widely used stool microscopy. PMID:27504954
Chu, Kevin; Hann, Angus; Greenslade, Jaimi; Williams, Julian; Brown, Anthony
2014-09-01
We assess the sensitivity and specificity of xanthochromia as adjudicated by visual inspection and spectrophotometry at predicting the presence of cerebral aneurysm in patients with suspected subarachnoid hemorrhage who have a normal computed tomography (CT) head scan result. A systematic review was performed. MEDLINE and EMBASE databases were searched. Relevant studies with clinical data on the diagnostic accuracy of visual inspection or spectrophotometry were considered. Patients who had a normal CT head scan result followed by a lumbar puncture were included in this review. Sensitivities, specificities, and heterogeneity (I(2)) were calculated. Subgroup analyses were performed to explore reasons for the heterogeneity. There were major methodological limitations in the studies found. Twenty-two relevant articles were heterogeneous in regard to time to lumbar puncture, spectrophotometry methods, and follow-up of patients not undergoing cerebral angiography. Twelve of the 22 studies selected patients on the basis of a cerebral aneurysm or subarachnoid hemorrhage on imaging, or a positive lumbar puncture result. These studies were excluded from our initial analysis, which included only patients with clinically suspected subarachnoid hemorrhage. In this initial analysis, pooled estimates of sensitivity and specificity for spectrophotometry were 87% (95% confidence interval [CI] 71% to 96%; I(2)=26%) and 86% (95% CI 84% to 88%; I(2)=96%), respectively. For visual inspection, pooled sensitivity and specificity were 83% (95% CI 59% to 96%; I(2)=52%) and 96% (95% CI 93% to 97%; I(2)=76%), respectively. Sensitivity estimates are difficult to interpret without knowing time to lumbar puncture. The heterogeneity in the underlying studies, combined with significant overlap in pooled confidence limits, makes it impossible to provide a definite conclusion about the diagnostic accuracy of spectrophotometry versus visual inspection. Copyright © 2014 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
Tantrakul, Visasiri; Numthavaj, Pawin; Guilleminault, Christian; McEvoy, Mark; Panburana, Panyu; Khaing, Win; Attia, John; Thakkinstian, Ammarin
2017-12-01
This review aims to evaluate the performance of obstructive sleep apnea (OSA) screening questionnaires during pregnancy. A systematic review and meta-analysis was performed using MEDLINE Scopus, CINAHL, and the Cochrane library. A bivariate meta-analysis was applied for pooling of diagnostic parameters. Six of the total 4719 articles met the inclusion criteria. The Berlin questionnaire (BQ, N = 604) and Epworth sleepiness scale (ESS, N = 420) were the most frequently used screening tools during pregnancy. The pooled prevalence of OSA during pregnancy was 26.7% (95%CI: 16.9%, 34.4%, I 2 = 83.15%). BQ performance was poor to fair with pooled sensitivity and specificity of 0.66 (95%CI: 0.45, 0.83; I 2 = 78.65%) and 0.62 (95%CI: 0.48, 0.75; I 2 = 81.55%), respectively. BQ performance was heterogeneous depending on type of reference test and pregnancy. Sensitivity increased if diagnosis was based on polysomnography (0.90), and respiratory disturbance index (0.90). However, sensitivity decreased if screening was performed in early pregnancy (≤20 weeks gestation: 0.47), and high-risk pregnancy (0.44). Performance of ESS was poor with pooled sensitivity and specificity of 0.44 (95%CI: 0.33, 0.56; I 2 = 32.8%) and 0.62 (95%CI: 0.48, 0.75; I 2 = 81.55%), respectively. In conclusion, BQ and ESS showed poor performance during pregnancy, hence a new OSA screening questionnaire is needed. Registration: PROSPERO registration CRD42015025848. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Ran, Li; Zhao, Wenli; Zhao, Ye; Bu, Huaien
2017-07-01
Contrast-enhanced ultrasound (CEUS) is considered a novel method for diagnosing pancreatic cancer, but currently, there is no conclusive evidence of its accuracy. Using CEUS in discriminating between pancreatic carcinoma and other pancreatic lesions, we aimed to evaluate the diagnostic accuracy of CEUS in predicting pancreatic tumours. Relevant studies were selected from the PubMed, Cochrane Library, Elsevier, CNKI, VIP, and WANFANG databases dating from January 2006 to May 2017. The following terms were used as keywords: "pancreatic cancer" OR "pancreatic carcinoma," "contrast-enhanced ultrasonography" OR "contrast-enhanced ultrasound" OR "CEUS," and "diagnosis." The selection criteria are as follows: pancreatic carcinomas diagnosed by CEUS while the main reference standard was surgical pathology or biopsy (if it involved a clinical diagnosis, particular criteria emphasized); SonoVue or Levovist was the contrast agent; true positive, false positive, false negative, and true negative rates were obtained or calculated to construct the 2 × 2 contingency table; English or Chinese articles; at least 20 patients were enrolled in each group. The Quality Assessment for Studies of Diagnostic Accuracy was employed to evaluate the quality of articles. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, summary receiver-operating characteristic curves, and the area under curve were evaluated to estimate the overall diagnostic efficiency. Pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio with 95% confidence intervals (CIs) were calculated with fixed-effect models. Eight of 184 records were eligible for a meta-analysis after independent scrutinization by 2 reviewers. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratios were 0.86 (95% CI 0.81-0.90), 0.75 (95% CI 0.68-0.82), 3.56 (95% CI 2.64-4.78), 0.19 (95% CI 0.13-0.27), and 22.260 (95% CI 8.980-55.177), respectively. The area under the SROC curve was 0.9088. CEUS has a satisfying pooled sensitivity and specificity for discriminating pancreatic cancer from other pancreatic lesions.
Ultrasonography in diagnosing clinically occult groin hernia: systematic review and meta-analysis.
Kwee, Robert M; Kwee, Thomas C
2018-05-14
To provide an updated systematic review on the performance of ultrasonography (US) in diagnosing clinically occult groin hernia. A systematic search was performed in MEDLINE and Embase. Methodological quality of included studies was assessed. Accuracy data of US in detecting clinically occult groin hernia were extracted. Positive predictive value (PPV) was pooled with a random effects model. For studies investigating the performance of US in hernia type classification (inguinal vs femoral), correctly classified proportion was assessed. Sixteen studies were included. In the two studies without verification bias, sensitivities were 29.4% [95% confidence interval (CI), 15.1-47.5%] and 90.9% (95% CI, 70.8-98.9%); specificities were 90.0% (95% CI, 80.5-95.9%) and 90.6% (95% CI, 83.0-95.6%). Verification bias or a variation of it (i.e. study limited to only subjects with definitive proof of disease status) was present in all other studies. Sensitivity, specificity, and negative predictive value (NPV) were not pooled. PPV ranged from 58.8 to 100%. Pooled PPV, based on data from ten studies with low risk of bias and no applicability concerns with respect to patient selection, was 85.6% (95% CI, 76.5-92.7%). Proportion of correctly classified hernias, based on data from four studies, ranged between 94.4% and 99.1%. Sensitivity, specificity and NPV of US in detecting clinically occult groin hernia cannot reliably be determined based on current evidence. Further studies are necessary. Accuracy may strongly depend on the examiner's skills. PPV is high. Inguinal and femoral hernias can reliably be differentiated by US. • Sensitivity, specificity and NPV of ultrasound in detecting clinically occult groin hernia cannot reliably be determined based on current evidence. • Accuracy may strongly depend on the examiner's skills. • PPV of US in detection of clinically occult groin hernia is high [pooled PPV of 85.6% (95% confidence interval, 76.5-92.7%)]. • US has very high performance in correctly differentiating between clinically occult inguinal and femoral hernia (correctness of 94.4- 99.1%).
Sun, Wenjing; Cui, Hongli; Li, Ning; Wei, Yanling; Lai, Shujie; Yang, Yang; Yin, Xinru; Chen, Dong-Feng
2016-08-01
Non-alcoholic fatty liver disease (NAFLD)-related advanced hepatic fibrosis is associated with liver and cardiovascular morbidity and mortality. This study aims to compare the FIB-4 index, NAFLD fibrosis score (NFS) and BARD score for prediction of advanced liver fibrosis. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), summary receiver-operator curves (SROC) and Spearman's rank correlation coefficient were used to examine the accuracy of each non-invasive scoring system for predicting NAFLD-related advanced fibrosis. Four studies with 1038 adult patients were included in this meta-analysis. A total of 135 patients (13.0%) had advanced fibrosis. In the FIB-4 index group, pooled sensitivity and specificity with 95% confidence interval (CI), and the area under the ROC (AUROC) were 0.844 (0.772-0.901), 0.685 (0.654-0.716) and 0.8496 ± 0.0680, respectively, at a cut-off of 1.30. At a threshold of 3.25, the same parameters were 0.38 (0.30-0.47), 0.96 (0.95-0.98) and 0.8445 ± 0.0981. At a cut-off of -1.455, values were 0.77 (0.69-0.84), 0.70 (0.67-0.73) and 0.8355 ± 0.0667, respectively. At a 0.676 cut-off, pooled sensitivity and specificity with 95% CI were 0.27 (0.19-0.35) and 0.98 (0.96-0.98), respectively; and the AUROC was 0.647 ± 0.2208. In the BARD score group, pooled sensitivity and specificity with 95% CI were 0.74 (0.66-0.81) and 0.66 (0.63-0.69), respectively; and the AUROC was 0.7625 ± 0.0285. FIB-4 index with a 1.30 cut-off has better diagnostic accuracy than the FIB-4 index with a 3.25 cut-off, NFS and BARD score, despite showing its limited value for predicting NAFLD-related advanced fibrosis. © 2016 The Japan Society of Hepatology.
Tao, Weijing; Shen, Yang; Guo, Lili; Bo, Genji
2014-01-01
Balanced steady-state free precession MR angiography (b-SSFP MRA) has shown great promise in diagnosing renal artery stenosis (RAS) as a non-contrast MR angiography (NC-MRA) method. However, results from related studies are inconsistent. The purpose of this meta-analysis was to assess the accuracy of b-SSFP MRA compared to contrast-enhanced MR angiography (CE-MRA) in diagnosing RAS. English and Chinese studies that were published prior to September 4, 2013 and that assessed b-SSFP MRA diagnostic performance in RAS patients were reviewed. Quality of the literature was assessed independently by two observers. The statistical analysis was adopted by the software of Meta-Disc version 1.4. Using the heterogeneity test, a statistical effect model was chosen to calculate different pooled weighted values. The receiver operator characteristic (ROC) space and Spearman correlation coefficient were to explore threshold effect. Sensitivity analysis and the publication bias were performed to demonstrate if the pooled estimates were stable and reliable. We produced forest plots to calculate the pooled values and corresponding 95% confidence interval (CI) of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and constructed a summary receiver operating characteristic curve (SROC) to calculate the area under the curve (AUC). A total of 10 high quality articles were used in this meta-analysis. The studies showed a high degree of heterogeneity. The "shoulder-arm" shape in the ROC plot and the Spearman correlation coefficient between the log(SEN) and log(1-SPE) suggested that there was a threshold effect. Sensitivity analysis demonstrated that the actual combined effect size was equal to the theoretical combined effect size. The publication bias was low after quality evaluation of the literature and the construction of a funnel plot. The pooled sensitivity was 0.88 (95% CI, 0.83-0.91) and pooled specificity was 0.94 (95% CI, 0.93-0.95); pooled PLR was 14.57 (95% CI, 9.78-21.71]) and pooled NLR was 0.15 (95% CI, 0.11-0.20). The AUC was 0.964 3. In contrast to CE-MRA, the b-SSFP MRA is more accurate in diagnosing RAS, and may be able to replace other diagnostic methods in patients with renal insufficiency.
Xpert® Mtb/Rif assay for pulmonary tuberculosis and rifampicin resistance in adults
Steingart, Karen R; Sohn, Hojoon; Schiller, Ian; Kloda, Lorie A; Boehme, Catharina C; Pai, Madhukar; Dendukuri, Nandini
2013-01-01
Background Accurate and rapid detection of tuberculosis (TB) and drug resistance are critical for improving patient care and decreasing the spread of TB. Xpert® MTB/RIF assay (Xpert) is a rapid, automated test that can detect both TB and rifampicin resistance, within two hours after starting the test, with minimal hands-on technical time, but is more expensive than conventional sputum microscopy. Objectives To assess the diagnostic accuracy of Xpert for pulmonary TB (TB detection), both where Xpert was used as an initial test replacing microscopy, and where Xpert was used as an add-on test following a negative smear microscopy result. To assess the diagnostic accuracy of Xpert for rifampicin resistance detection where Xpert was used as the initial test, replacing conventional culture-based drug susceptibility testing. The population of interest was adults suspected of having pulmonary TB or multidrug-resistant TB (MDR-TB), with or without HIV infection. Search methods We performed a comprehensive search of the following databases: Cochrane Infectious Diseases Group Specialized Register; MEDLINE; EMBASE; ISI Web of Knowledge; MEDION; LILACS; BIOSIS; and SCOPUS. We also searched the metaRegister of Controlled Trials (mRCT) and the search portal of the WHO International Clinical Trials Registry Platform to identify ongoing trials. We performed searches on 25 September 2011 and we repeated them on 15 December 2011, without language restriction. Selection criteria We included randomized controlled trials, cross-sectional, and cohort studies that used respiratory specimens to compare Xpert with culture for detecting TB and Xpert with conventional phenotypic drug susceptibility testing for detecting rifampicin resistance. Data collection and analysis For each study, two review authors independently extracted a set of data using a standardized data extraction form. When possible, we extracted data for subgroups by smear and HIV status. We assessed the quality of studies using the QUADAS-2 tool. We carried out meta-analyses to estimate the pooled sensitivity and specificity of Xpert separately for TB detection and rifampicin resistance detection using a bivariate random-effects model. We estimated the median pooled sensitivity and specificity and their 95% credible intervals (CrI). Main results We identified 18 unique studies as eligible for this review, including two multicentre international studies, one with five and the other with six distinct study centres. The majority of studies (55.6%) were performed in low-income and middle-income countries. In 17 of the 18 studies, Xpert was performed by trained technicians in reference laboratories. When used as an initial test replacing smear microscopy (15 studies, 7517 participants), Xpert achieved a pooled sensitivity of 88% (95% CrI 83% to 92%) and pooled specificity of 98% (95% CrI 97% to 99%). As an add-on test following a negative smear microscopy result (14 studies, 5719 participants), Xpert yielded a pooled sensitivity of 67% (95% CrI 58% to 74%) and pooled specificity of 98% (95% CrI 97% to 99%). In clinical subgroups, we found the following accuracy estimates: the pooled sensitivity was 98% (95% CrI 97% to 99%) for smear-positive, culture-positive TB and 68% (95% CrI 59% to 75%) for smear-negative, culture-positive TB (15 studies); the pooled sensitivity was 80% (95% CrI 67% to 88%) in people living with HIV and 89% (95% CrI 81% to 94%) in people without HIV infection (four studies). For rifampicin resistance detection (11 studies, 2340 participants), Xpert achieved a pooled sensitivity of 94% (95% CrI 87% to 97%) and pooled specificity of 98% (95% CrI 97% to 99%). In a separate analysis, Xpert could distinguish between TB and nontuberculous mycobacteria (NTM) in clinical samples with high accuracy: among 139 specimens with NTM, Xpert was positive in only one specimen that grew NTM. In a hypothetical cohort of 1000 individuals suspected of having rifampicin resistance (a proxy for MDR-TB), where the prevalence of rifampicin resistance is 30%, we estimated that on average Xpert would wrongly identify 14 patients as being rifampicin resistant. In comparison, where the prevalence of rifampicin resistance is only 2%, we estimated that the number of individuals wrongly identified as rifampicin resistant would increase to 20, an increase of 43%. Authors' conclusions This review shows that Xpert used as an initial diagnostic test for TB detection and rifampicin resistance detection in patients suspected of having TB, MDR-TB, or HIV-associated TB is sensitive and specific. Xpert may also be valuable as an add-on test following microscopy for patients who have previously been found to be smear-negative. An Xpert result that is positive for rifampicin resistance should be carefully interpreted and take into consideration the risk of MDR-TB in a given patient and the expected prevalence of MDR-TB in a given setting. Studies in this review mainly assessed sensitivity and specificity of the test when used in reference laboratories in research investigations. Most studies were performed in high TB burden countries. Ongoing use of Xpert in high TB burden countries will contribute to the evidence base on the diagnostic accuracy and clinical impact of Xpert in routine programmatic and peripheral health care settings, including settings where the test is performed at the point of care. PMID:23440842
Physical examination for lumbar radiculopathy due to disc herniation in patients with low-back pain.
van der Windt, Daniëlle Awm; Simons, Emmanuel; Riphagen, Ingrid I; Ammendolia, Carlo; Verhagen, Arianne P; Laslett, Mark; Devillé, Walter; Deyo, Rick A; Bouter, Lex M; de Vet, Henrica Cw; Aertgeerts, Bert
2010-02-17
Low-back pain with leg pain (sciatica) may be caused by a herniated intervertebral disc exerting pressure on the nerve root. Most patients will respond to conservative treatment, but in carefully selected patients, surgical discectomy may provide faster relief of symptoms. Primary care clinicians use patient history and physical examination to evaluate the likelihood of disc herniation and select patients for further imaging and possible surgery. (1) To assess the performance of tests performed during physical examination (alone or in combination) to identify radiculopathy due to lower lumbar disc herniation in patients with low-back pain and sciatica;(2) To assess the influence of sources of heterogeneity on diagnostic performance. We searched electronic databases for primary studies: PubMed (includes MEDLINE), EMBASE, and CINAHL, and (systematic) reviews: PubMed and Medion (all from earliest until 30 April 2008), and checked references of retrieved articles. We considered studies if they compared the results of tests performed during physical examination on patients with back pain with those of diagnostic imaging (MRI, CT, myelography) or findings at surgery. Two review authors assessed the quality of each publication with the QUADAS tool, and extracted details on patient and study design characteristics, index tests and reference standard, and the diagnostic two-by-two table. We presented information on sensitivities and specificities with 95% confidence intervals (95% CI) for all aspects of physical examination. Pooled estimates of sensitivity and specificity were computed for subsets of studies showing sufficient clinical and statistical homogeneity. We included 16 cohort studies (median N = 126, range 71 to 2504) and three case control studies (38 to100 cases). Only one study was carried out in a primary care population. When used in isolation, diagnostic performance of most physical tests (scoliosis, paresis or muscle weakness, muscle wasting, impaired reflexes, sensory deficits) was poor. Some tests (forward flexion, hyper-extension test, and slump test) performed slightly better, but the number of studies was small. In the one primary care study, most tests showed higher specificity and lower sensitivity compared to other settings.Most studies assessed the Straight Leg Raising (SLR) test. In surgical populations, characterized by a high prevalence of disc herniation (58% to 98%), the SLR showed high sensitivity (pooled estimate 0.92, 95% CI: 0.87 to 0.95) with widely varying specificity (0.10 to 1.00, pooled estimate 0.28, 95% CI: 0.18 to 0.40). Results of studies using imaging showed more heterogeneity and poorer sensitivity. The crossed SLR showed high specificity (pooled estimate 0.90, 95% CI: 0.85 to 0.94) with consistently low sensitivity (pooled estimate 0.28, 95% CI: 0.22 to 0.35).Combining positive test results increased the specificity of physical tests, but few studies presented data on test combinations. When used in isolation, current evidence indicates poor diagnostic performance of most physical tests used to identify lumbar disc herniation. However, most findings arise from surgical populations and may not apply to primary care or non-selected populations. Better performance may be obtained when tests are combined.
Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa
2017-11-01
Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake subanalyses based on HIV co-infection. Oral HCV Ab RDTs also had excellent sensitivity and specificity compared to blood reference tests, respectively at 94% (95% CI 93-96%) and 100% (95% CI 100-100%). Among studies that assessed individual oral RDTs, the eight studies revealed that OraQuick ADVANCE® had a slightly higher sensitivity (98%, 95% CI 97-98%) compared to the other oral brands (pooled sensitivity: 88%, 95% CI 84-92%). RDTs, including oral tests, have excellent sensitivity and specificity compared to laboratory-based methods for HCV antibody detection across a wide range of settings. Oral HCV Ab RDTs had good sensitivity and specificity compared to blood reference standards.
Nafisi Moghadam, Reza; Amlelshahbaz, Amir Pasha; Namiranian, Nasim; Sobhan-Ardekani, Mohammad; Emami-Meybodi, Mahmood; Dehghan, Ali; Rahmanian, Masoud; Razavi-Ratki, Seid Kazem
2017-12-28
Objective: Ultrasonography (US) and parathyroid scintigraphy (PS) with 99mTc-MIBI are common methods for preoperative localization of parathyroid adenomas but there discrepancies exist with regard to diagnostic accuracy. The aim of the study was to compare PS and US for localization of parathyroid adenoma with a systematic review and meta-analysis of the literature. Methods: Pub Med, Scopus (EMbase), Web of Science and the reference lists of all included studies were searched up to 1st January 2016. The search strategy was according PICO characteristics. Heterogeneity between the studies was accounted by P < 0.1. Point estimates were pooled estimate of sensitivity, specificity and positive predictive value of SPECT and ultrasonography with 99% confidence intervals (CIs) by pooling available data. Data analysis was performed using Meta-DiSc software (version 1.4). Results: Among 188 studies and after deletion of duplicated studies (75), a total of 113 titles and abstracts were studied. From these, 12 studies were selected. The meta-analysis determined a pooled sensitivity for scintigraphy of 83% [99% confidence interval (CI) 96.358 -97.412] and for ultra-sonography of 80% [99% confidence interval (CI) 76-83]. Similar results for specificity were also obtained for both approache. Conclusion: According this meta- analysis, there were no significant differences between the two methods in terms of sensitivity and specificity. There were overlaps in 99% confidence intervals. Also features of the two methods are similar. Creative Commons Attribution License
Jin, H; Yuan, L; Li, C; Kan, Y; Hao, R; Yang, J
2014-03-01
The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.
A systematic review of screening questionnaires for childhood lead poisoning.
Ossiander, Eric M
2013-01-01
The Centers for Disease Control and Prevention encourages the use of risk factor questionnaires to screen children for lead poisoning. A majority of state health departments have formal lead screening guidelines that recommend health care providers use questionnaires. We conducted a systematic review to evaluate the ability of lead screening questionnaires to predict lead poisoning risk among children. Articles that reported the evaluation of a predesigned lead screening questionnaire were obtained by searching Medline/PubMed and by examining references of articles obtained through the online search. From each evaluation, we abstracted the number of children that were true positive, false positive, true negative, and false negative, according to the results of the screening questionnaire and the follow-up blood lead test. From these data, we calculated specificity and sensitivity of the questionnaire for each evaluation. Twenty articles met the inclusion criteria: these included 28 separate questionnaire evaluations. Among 17 evaluations of the 1991 Centers for Disease Control and Prevention questionnaire, sensitivity ranged from 0.25 to 0.87, specificity from 0.31 to 0.80, and accuracy (sum of sensitivity and specificity) from 0.74 to 1.39. The pooled mean estimates for this questionnaire were sensitivity 0.61 (95% confidence interval: 0.53-0.68); specificity 0.52 (0.45-0.60); accuracy 1.12 (1.06-1.18). Among 11 evaluations of all other questionnaires, sensitivity ranged from 0.43 to 0.90, specificity from 0.17 to 0.66, and accuracy from 0.94 to 1.27. For these questionnaires, the pooled mean estimates were sensitivity 0.76 (0.68-0.85), specificity 0.41 (0.33-0.49), and accuracy 1.12 (1.06-1.18). Lead screening questionnaires showed a wide range of sensitivity and specificity and performed little better than chance at predicting lead poisoning risk among children.
Kim, Jun H; Lee, Kyung H; Kim, Kyoung-Tae; Kim, Hyun J; Ahn, Hyeong S; Kim, Yeo J; Lee, Ha Y; Jeon, Yong S
2016-12-01
To compare the diagnostic accuracy of digital tomosynthesis (DTS) with that of chest radiography for the detection of pulmonary nodules by meta-analysis. A systematic literature search was performed to identify relevant original studies from 1 January 1 1976 to 31 August 31 2016. The quality of included studies was assessed by quality assessment of diagnostic accuracy studies-2. Per-patient data were used to calculate the sensitivity and specificity and per-lesion data were used to calculate the detection rate. Summary receiver-operating characteristic curves were drawn for pulmonary nodule detection. 16 studies met the inclusion criteria. 1017 patients on a per-patient basis and 2159 lesions on a per-lesion basis from 16 eligible studies were evaluated. The pooled patient-based sensitivity of DTS was 0.85 [95% confidence interval (CI) 0.83-0.88] and the specificity was 0.95 (0.93-0.96). The pooled sensitivity and specificity of chest radiography were 0.47 (0.44-0.51) and 0.37 (0.34-0.40), respectively. The per-lesion detection rate was 2.90 (95% CI 2.63-3.19). DTS has higher diagnostic accuracy than chest radiography for detection of pulmonary nodules. Chest radiography has low sensitivity but similar specificity, comparable with that of DTS. Advances in knowledge: DTS has higher diagnostic accuracy than chest radiography for the detection of pulmonary nodules.
Detecting anxiety in individuals with Parkinson disease: A systematic review.
Mele, Bria; Holroyd-Leduc, Jayna; Smith, Eric E; Pringsheim, Tamara; Ismail, Zahinoor; Goodarzi, Zahra
2018-01-02
To examine diagnostic accuracy of anxiety detection tools compared with a gold standard in outpatient settings among adults with Parkinson disease (PD). A systematic review was conducted. MEDLINE, EMABASE, PsycINFO, and Cochrane Database of Systematic Reviews were searched to April 7, 2017. Prevalence of anxiety and diagnostic accuracy measures including sensitivity, specificity, and likelihood ratios were gathered. Pooled prevalence of anxiety was calculated using Mantel-Haenszel-weighted DerSimonian and Laird models. A total of 6,300 citations were reviewed with 6 full-text articles included for synthesis. Tools included within this study were the Beck Anxiety Inventory, Geriatric Anxiety Inventory (GAI), Hamilton Anxiety Rating Scale, Hospital Anxiety and Depression Scale-Anxiety, Parkinson's Anxiety Scale (PAS), and Mini-Social Phobia Inventory. Anxiety diagnoses made included generalized anxiety disorder, social phobia, and any anxiety type. Pooled prevalence of anxiety was 30.1% (95% confidence interval 26.1%-34.0%). The GAI had the best-reported sensitivity of 0.86 and specificity of 0.88. The observer-rated PAS had a sensitivity of 0.71 and the highest specificity of 0.91. While there are 6 tools validated for anxiety screening in PD populations, most tools are only validated in single studies. The GAI is brief and easy to use, with a good balance of sensitivity and specificity. The PAS was specifically developed for PD, is brief, and has self-/observer-rated scales, but with lower sensitivity. Health care practitioners involved in PD care need to be aware of available validated tools and choose one that fits their practice. Copyright © 2017 American Academy of Neurology.
McCormick, Natalie; Lacaille, Diane; Bhole, Vidula; Avina-Zubieta, J. Antonio
2014-01-01
Objective Heart failure (HF) is an important covariate and outcome in studies of elderly populations and cardiovascular disease cohorts, among others. Administrative data is increasingly being used for long-term clinical research in these populations. We aimed to conduct the first systematic review and meta-analysis of studies reporting on the validity of diagnostic codes for identifying HF in administrative data. Methods MEDLINE and EMBASE were searched (inception to November 2010) for studies: (a) Using administrative data to identify HF; or (b) Evaluating the validity of HF codes in administrative data; and (c) Reporting validation statistics (sensitivity, specificity, positive predictive value [PPV], negative predictive value, or Kappa scores) for HF, or data sufficient for their calculation. Additional articles were located by hand search (up to February 2011) of original papers. Data were extracted by two independent reviewers; article quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool. Using a random-effects model, pooled sensitivity and specificity values were produced, along with estimates of the positive (LR+) and negative (LR−) likelihood ratios, and diagnostic odds ratios (DOR = LR+/LR−) of HF codes. Results Nineteen studies published from1999–2009 were included in the qualitative review. Specificity was ≥95% in all studies and PPV was ≥87% in the majority, but sensitivity was lower (≥69% in ≥50% of studies). In a meta-analysis of the 11 studies reporting sensitivity and specificity values, the pooled sensitivity was 75.3% (95% CI: 74.7–75.9) and specificity was 96.8% (95% CI: 96.8–96.9). The pooled LR+ was 51.9 (20.5–131.6), the LR− was 0.27 (0.20–0.37), and the DOR was 186.5 (96.8–359.2). Conclusions While most HF diagnoses in administrative databases do correspond to true HF cases, about one-quarter of HF cases are not captured. The use of broader search parameters, along with laboratory and prescription medication data, may help identify more cases. PMID:25126761
Di Leo, Giovanni; Fisci, Erica; Secchi, Francesco; Alì, Marco; Ambrogi, Federico; Sconfienza, Luca Maria; Sardanelli, Francesco
2016-10-01
To review the diagnostic performance of MR coronary angiography (MRCA) for coronary artery disease (CAD). Two independent reviewers searched on MEDLINE/EMBASE with the following inclusion criteria: 01/01/2000-03/23/2015 publication date; per-patient sensitivity/specificity for >50 % stenosis confirmed by conventional coronary angiography with raw data provided or retrievable; sample size >10. Quality was appraised using QUADAS2. Nine hundred eighteen studies were retrieved, 24 of them, including 1,638 patients, were selected. Using a bivariate model, the pooled sensitivity was 89 % (95 % confidence interval 86-92 %), the pooled specificity 72 % (63-79 %). Meta-regression did not show a significant impact on sensitivity/specificity for both year of publication and disease prevalence (p ≥ 0.114). Sensitivity of contrast-enhanced examinations (95 %, 90-97 %) was higher (p = 0.005) than that of unenhanced examinations (87 %, 83-90 %). Specificity of whole-heart acquisition mode (78 %, 72-84 %) was higher (p = 0.006) than that of targeted mode (57 %, 45-69 %). Specificity at 3 T (83 %, 69-92 %) was higher (p = 0.067) than that at 1.5 T (68 %, 60-76 %). Risk of bias and concerns regarding applicability were low. Sensitivity and specificity of MRCA for CAD were 89 % and 72 %, respectively. A specificity higher than 80 % may be obtained at 3 T. Whole-heart contrast-enhanced protocols should be preferred for a higher diagnostic performance. • MRCA sensitivity and specificity for CAD are below those of CTA. • Contrast administration increased sensitivity to 95 % (90-97 %), comparable with that of CTA. • Whole-heart mode increased specificity to 78 % (72-84 %), comparable with that of CTA. • Specificity at 3 T was borderline-significantly higher (p = 0.067) than at 1.5 T. • Whole-heart contrast-enhanced protocols are the best approach for MRCA.
Bittencourt, C A; Dos Santos Simões, R; Bernardo, W M; Fuchs, L F P; Soares Júnior, J M; Pastore, A R; Baracat, E C
2017-07-01
To analyze the diagnostic accuracy of two- (2D) and three- (3D) dimensional saline contrast sonohysterography (SCSH) in the detection of endometrial polyps and submucosal uterine leiomyomas in women of reproductive age with abnormal uterine bleeding compared with gold standard hysteroscopy. A systematic review of diagnostic studies that compared 2D- and/or 3D-SCSH with hysteroscopy and anatomopathology was conducted according to PRISMA and SEDATE recommendations. The databases MEDLINE, EMBASE and The Cochrane Library were searched electronically using specific terms with no restriction on language or publication year. Quality assessment of included studies was performed using the QUADAS-2 tool. Meta-analysis was performed with the Meta-DiSk program and data presented as forest plots and summary receiver-operating characteristics (SROC) curves. Pooled sensitivity, specificity and positive (LR+) and negative (LR-) likelihood ratios of SCSH in the detection of uterine cavity abnormalities were calculated. A total of 1398 citations were identified and five studies were included in the systematic review and meta-analysis. Pooled sensitivity and specificity of 2D-SCSH in detecting endometrial polyps were 93% (95% CI, 89-96%) and 81% (95% CI, 76-86%), respectively, with pooled LR+ of 5.41 (95% CI, 2.60-11.28) and LR- of 0.10 (95% CI, 0.06-0.17). In the detection of submucosal uterine leiomyomas, pooled sensitivity and specificity were 94% (95% CI, 89-97%) and 81% (95% CI, 76-86%), respectively, with pooled LR+ of 4.25 (95% CI, 2.20-8.21) and LR- of 0.11 (95% CI, 0.05-0.22). 2D-SCSH had good accuracy in detecting endometrial polyps and submucosal uterine leiomyomas, with areas under the SROC curves of 0.97 ± 0.02 and 0.97 ± 0.03, respectively. Studies that analyzed the diagnostic accuracy of 3D-SCSH could not be compared due to high heterogeneity related to menopausal status, type of technique used and primary outcome being investigation of infertility. 2D-SCSH proved to be a highly sensitive method for detection of endometrial polyps and submucosal uterine leiomyomas, making it a potential first-line diagnostic method in the work-up for women with abnormal uterine bleeding. More studies are needed on 3D-SCSH in women of reproductive age. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Iftikhar, Imran H; Alghothani, Lana; Sardi, Alejandro; Berkowitz, David; Musani, Ali I
2017-07-01
Transbronchial lung cryobiopsy is increasingly being used for the assessment of diffuse parenchymal lung diseases. Several studies have shown larger biopsy samples and higher yields compared with conventional transbronchial biopsies. However, the higher risk of bleeding and other complications has raised concerns for widespread use of this modality. To study the diagnostic accuracy and safety profile of transbronchial lung cryobiopsy and compare with video-assisted thoracoscopic surgery (VATS) by reviewing available evidence from the literature. Medline and PubMed were searched from inception until December 2016. Data on diagnostic performance were abstracted by constructing two-by-two contingency tables for each study. Data on a priori selected safety outcomes were collected. Risk of bias was assessed with the Quality Assessment of Diagnostic Accuracy Studies tool. Random effects meta-analyses were performed to obtain summary estimates of the diagnostic accuracy. The pooled diagnostic yield, pooled sensitivity, and pooled specificity of transbronchial lung cryobiopsy were 83.7% (76.9-88.8%), 87% (85-89%), and 57% (40-73%), respectively. The pooled diagnostic yield, pooled sensitivity, and pooled specificity of VATS were 92.7% (87.6-95.8%), 91.0% (89-92%), and 58% (31-81%), respectively. The incidence of grade 2 (moderate to severe) endobronchial bleeding after transbronchial lung cryobiopsy and of post-procedural pneumothorax was 4.9% (2.2-10.7%) and 9.5% (5.9-14.9%), respectively. Although the diagnostic test accuracy measures of transbronchial lung cryobiopsy lag behind those of VATS, with an acceptable safety profile and potential cost savings, the former could be considered as an alternative in the evaluation of patients with diffuse parenchymal lung diseases.
Lippi, Giuseppe; Mattiuzzi, Camilla; Cervellin, Gianfranco
2013-01-01
An early diagnosis is crucial for effective triage and management of patients with suspected acute myocardial infarction (AMI). Although troponin testing is the cornerstone of diagnosis, the sensitivity of this biomarker is still suboptimal at patient admission. The heart-type fatty acid binding protein (H-FABP) is an early and sensitive biomarker of myocardial ischemia, whose appropriate setting is in combination with troponin testing. We performed a systematic review and meta-analysis of articles that have assessed the combination of troponin and H-FABP in the early diagnosis of AMI. Eight studies, totaling 2735 patients, met the inclusion criteria but none of them used a high-sensitivity troponin immunoassay. The between-study variation was high (98.5%), and attributable to heterogeneity. When considered alone, troponin exhibited a significantly greater pooled area under the curve (AUC) than H-FABP alone (0.820 versus 0.784; p<0.001). The pooled specificity was also higher for troponin alone than for H-FABP alone (0.94 versus 0.83; p<0.001), whereas the cumulative sensitivity was lower for troponin than for H-FABP (0.73 versus 0.80; p=0.02). The combination of both biomarkers exhibited a greater AUC than troponin alone (0.881; p<0.001), as well as a higher pooled sensitivity (0.91; p<0.001), which was however counterbalanced by a lower specificity (0.82; p<0.001). These results attest that the combination of H-FABP with a conventional troponin immunoassay seems advantageous for increasing the sensitivity of the former biomarker, at the expense of a lower specificity. The introduction of H-FABP testing would hence require careful assessment of laboratory data or clinical signs and symptoms for excluding sources of elevation different from AMI. Further studies are needed to assess the diagnostic effectiveness of combining H-FABP with a high-sensitivity troponin immunoassay. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Alcoholism Detection by Data Augmentation and Convolutional Neural Network with Stochastic Pooling.
Wang, Shui-Hua; Lv, Yi-Ding; Sui, Yuxiu; Liu, Shuai; Wang, Su-Jing; Zhang, Yu-Dong
2017-11-17
Alcohol use disorder (AUD) is an important brain disease. It alters the brain structure. Recently, scholars tend to use computer vision based techniques to detect AUD. We collected 235 subjects, 114 alcoholic and 121 non-alcoholic. Among the 235 image, 100 images were used as training set, and data augmentation method was used. The rest 135 images were used as test set. Further, we chose the latest powerful technique-convolutional neural network (CNN) based on convolutional layer, rectified linear unit layer, pooling layer, fully connected layer, and softmax layer. We also compared three different pooling techniques: max pooling, average pooling, and stochastic pooling. The results showed that our method achieved a sensitivity of 96.88%, a specificity of 97.18%, and an accuracy of 97.04%. Our method was better than three state-of-the-art approaches. Besides, stochastic pooling performed better than other max pooling and average pooling. We validated CNN with five convolution layers and two fully connected layers performed the best. The GPU yielded a 149× acceleration in training and a 166× acceleration in test, compared to CPU.
Pi, Shan; Cao, Rong; Qiang, Jin Wei; Guo, Yan Hui
2018-01-01
Background Diffusion-weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) values are widely used in the differential diagnosis of ovarian tumors. Purpose To assess the diagnostic performance of quantitative ADC values in ovarian tumors. Material and Methods PubMed, Embase, the Cochrane Library, and local databases were searched for studies assessing ovarian tumors using quantitative ADC values. We quantitatively analyzed the diagnostic performances for two clinical problems: benign vs. malignant tumors and borderline vs. malignant tumors. We evaluated diagnostic performances by the pooled sensitivity and specificity values and by summary receiver operating characteristic (SROC) curves. Subgroup analyses were used to analyze study heterogeneity. Results From the 742 studies identified in the search results, 16 studies met our inclusion criteria. A total of ten studies evaluated malignant vs. benign ovarian tumors and six studies assessed malignant vs. borderline ovarian tumors. Regarding the diagnostic accuracy of quantitative ADC values for distinguishing between malignant and benign ovarian tumors, the pooled sensitivity and specificity values were 0.91 and 0.91, respectively. The area under the SROC curve (AUC) was 0.96. For differentiating borderline from malignant tumors, the pooled sensitivity and specificity values were 0.89 and 0.79, and the AUC was 0.91. The methodological quality of the included studies was moderate. Conclusion Quantitative ADC values could serve as useful preoperative markers for predicting the nature of ovarian tumors. Nevertheless, prospective trials focused on standardized imaging parameters are needed to evaluate the clinical value of quantitative ADC values in ovarian tumors.
Gutting, Bradford W; Rukhin, Andrey; Mackie, Ryan S; Marchette, David; Thran, Brandolyn
2015-05-01
The application of the exponential model is extended by the inclusion of new nonhuman primate (NHP), rabbit, and guinea pig dose-lethality data for inhalation anthrax. Because deposition is a critical step in the initiation of inhalation anthrax, inhaled doses may not provide the most accurate cross-species comparison. For this reason, species-specific deposition factors were derived to translate inhaled dose to deposited dose. Four NHP, three rabbit, and two guinea pig data sets were utilized. Results from species-specific pooling analysis suggested all four NHP data sets could be pooled into a single NHP data set, which was also true for the rabbit and guinea pig data sets. The three species-specific pooled data sets could not be combined into a single generic mammalian data set. For inhaled dose, NHPs were the most sensitive (relative lowest LD50) species and rabbits the least. Improved inhaled LD50 s proposed for use in risk assessment are 50,600, 102,600, and 70,800 inhaled spores for NHP, rabbit, and guinea pig, respectively. Lung deposition factors were estimated for each species using published deposition data from Bacillus spore exposures, particle deposition studies, and computer modeling. Deposition was estimated at 22%, 9%, and 30% of the inhaled dose for NHP, rabbit, and guinea pig, respectively. When the inhaled dose was adjusted to reflect deposited dose, the rabbit animal model appears the most sensitive with the guinea pig the least sensitive species. © 2014 Society for Risk Analysis.
Tong, Xiang; Wang, Ye; Wang, Chengdi; Jin, Jing; Tian, Panwen; Li, Weimin
2018-01-01
Objectives Although different methods have been established to detect epidermal growth factor receptor (EGFR) T790M mutation in circulating tumor DNA (ctDNA), a wide range of diagnostic accuracy values were reported in previous studies. The aim of this meta-analysis was to provide pooled diagnostic accuracy measures for droplet digital PCR (ddPCR) in the diagnosis of EGFR T790M mutation based on ctDNA. Materials and methods A systematic review and meta-analysis were carried out based on resources from Pubmed, Web of Science, Embase and Cochrane Library up to October 11, 2017. Data were extracted to assess the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio (NLR), diagnostic OR (DOR), and areas under the summary receiver-operating characteristic curve (SROC). Results Eleven of 311 studies identified have met the including criteria. The sensitivity and specificity of ddPCR for the detection of T790M mutation in ctDNA ranged from 0.0% to 100.0% and 63.2% to 100.0%, respectively. For the pooled analysis, ddPCR had a performance of 70.1% (95% CI, 62.7%–76.7%) sensitivity, 86.9 % (95% CI, 80.6%–91.7%) specificity, 3.67 (95% CI, 2.33–5.79) PLR, 0.41 (95% CI, 0.32–0.55) NLR, and 10.83 (95% CI, 5.86–20.03) DOR, with the area under the SROC curve being 0.82. Conclusion The ddPCR harbored a good performance for detection of EGFR T790M mutation in ctDNA. PMID:29844700
Liu, C Carrie; Jethwa, Ashok R; Khariwala, Samir S; Johnson, Jonas; Shin, Jennifer J
2016-01-01
(1) To analyze the sensitivity and specificity of fine-needle aspiration (FNA) in distinguishing benign from malignant parotid disease. (2) To determine the anticipated posttest probability of malignancy and probability of nondiagnostic and indeterminate cytology with parotid FNA. Independently corroborated computerized searches of PubMed, Embase, and Cochrane Central Register were performed. These were supplemented with manual searches and input from content experts. Inclusion/exclusion criteria specified diagnosis of parotid mass, intervention with both FNA and surgical excision, and enumeration of both cytologic and surgical histopathologic results. The primary outcomes were sensitivity, specificity, and posttest probability of malignancy. Heterogeneity was evaluated with the I(2) statistic. Meta-analysis was performed via a 2-level mixed logistic regression model. Bayesian nomograms were plotted via pooled likelihood ratios. The systematic review yielded 70 criterion-meeting studies, 63 of which contained data that allowed for computation of numerical outcomes (n = 5647 patients; level 2a) and consideration of meta-analysis. Subgroup analyses were performed in studies that were prospective, involved consecutive patients, described the FNA technique utilized, and used ultrasound guidance. The I(2) point estimate was >70% for all analyses, except within prospectively obtained and ultrasound-guided results. Among the prospective subgroup, the pooled analysis demonstrated a sensitivity of 0.882 (95% confidence interval [95% CI], 0.509-0.982) and a specificity of 0.995 (95% CI, 0.960-0.999). The probabilities of nondiagnostic and indeterminate cytology were 0.053 (95% CI, 0.030-0.075) and 0.147 (95% CI, 0.106-0.188), respectively. FNA has moderate sensitivity and high specificity in differentiating malignant from benign parotid lesions. Considerable heterogeneity is present among studies. © American Academy of Otolaryngology-Head and Neck Surgery Foundation 2015.
Liu, C. Carrie; Jethwa, Ashok R.; Khariwala, Samir S.; Johnson, Jonas; Shin, Jennifer J.
2016-01-01
Objectives (1) To analyze the sensitivity and specificity of fine-needle aspiration (FNA) in distinguishing benign from malignant parotid disease. (2) To determine the anticipated posttest probability of malignancy and probability of non-diagnostic and indeterminate cytology with parotid FNA. Data Sources Independently corroborated computerized searches of PubMed, Embase, and Cochrane Central Register were performed. These were supplemented with manual searches and input from content experts. Review Methods Inclusion/exclusion criteria specified diagnosis of parotid mass, intervention with both FNA and surgical excision, and enumeration of both cytologic and surgical histopathologic results. The primary outcomes were sensitivity, specificity, and posttest probability of malignancy. Heterogeneity was evaluated with the I2 statistic. Meta-analysis was performed via a 2-level mixed logistic regression model. Bayesian nomograms were plotted via pooled likelihood ratios. Results The systematic review yielded 70 criterion-meeting studies, 63 of which contained data that allowed for computation of numerical outcomes (n = 5647 patients; level 2a) and consideration of meta-analysis. Subgroup analyses were performed in studies that were prospective, involved consecutive patients, described the FNA technique utilized, and used ultrasound guidance. The I2 point estimate was >70% for all analyses, except within prospectively obtained and ultrasound-guided results. Among the prospective subgroup, the pooled analysis demonstrated a sensitivity of 0.882 (95% confidence interval [95% CI], 0.509–0.982) and a specificity of 0.995 (95% CI, 0.960–0.999). The probabilities of nondiagnostic and indeterminate cytology were 0.053 (95% CI, 0.030–0.075) and 0.147 (95% CI, 0.106–0.188), respectively. Conclusion FNA has moderate sensitivity and high specificity in differentiating malignant from benign parotid lesions. Considerable heterogeneity is present among studies. PMID:26428476
van Dijken, Bart R J; van Laar, Peter Jan; Holtman, Gea A; van der Hoorn, Anouk
2017-10-01
Treatment response assessment in high-grade gliomas uses contrast enhanced T1-weighted MRI, but is unreliable. Novel advanced MRI techniques have been studied, but the accuracy is not well known. Therefore, we performed a systematic meta-analysis to assess the diagnostic accuracy of anatomical and advanced MRI for treatment response in high-grade gliomas. Databases were searched systematically. Study selection and data extraction were done by two authors independently. Meta-analysis was performed using a bivariate random effects model when ≥5 studies were included. Anatomical MRI (five studies, 166 patients) showed a pooled sensitivity and specificity of 68% (95%CI 51-81) and 77% (45-93), respectively. Pooled apparent diffusion coefficients (seven studies, 204 patients) demonstrated a sensitivity of 71% (60-80) and specificity of 87% (77-93). DSC-perfusion (18 studies, 708 patients) sensitivity was 87% (82-91) with a specificity of 86% (77-91). DCE-perfusion (five studies, 207 patients) sensitivity was 92% (73-98) and specificity was 85% (76-92). The sensitivity of spectroscopy (nine studies, 203 patients) was 91% (79-97) and specificity was 95% (65-99). Advanced techniques showed higher diagnostic accuracy than anatomical MRI, the highest for spectroscopy, supporting the use in treatment response assessment in high-grade gliomas. • Treatment response assessment in high-grade gliomas with anatomical MRI is unreliable • Novel advanced MRI techniques have been studied, but diagnostic accuracy is unknown • Meta-analysis demonstrates that advanced MRI showed higher diagnostic accuracy than anatomical MRI • Highest diagnostic accuracy for spectroscopy and perfusion MRI • Supports the incorporation of advanced MRI in high-grade glioma treatment response assessment.
Webb, D J; Newman, D J; Chaturvedi, N; Fuller, J H
1996-03-01
In IDDM, microalbuminuria (urinary albumin excretion rate (AER) of 20-200 micrograms/min) is a predictor of persistent proteinuria and diabetic nephropathy. Early intervention may prevent or reduce the rate of progression of renal complications. The Micral-Test strip can be used to establish a semi-quantitative estimate of AER. We assessed the field performance of the Micral-Test strip in detecting microalbuminuria in the EUCLID study, an European wide, 18 centre study of 530 IDDM participants, aged 20 to 59 years. People with macroalbuminuria were excluded. On entry, all participants had albumin concentrations from two overnight urine collections measured by a central laboratory, and the corresponding Micral-Test performed on the two collections locally. a cut off of > or = mg/l albumin from the first Micral-Test, to detect a centrally measured albumin concentration > or = 20 mg/l, yielded 29 (5.8%) false negative results and 58 (11.6%) false positive results (sensitivity 70%, specificity 87%). The mean AER, from two collections, was compared with the corresponding 'pooled' Micral-Test results (mean of the two readings). Receiver Operating Characteristic (ROC) curves were used to assess if there was a suitable 'pooled' Micral-Test result for screening microalbuminuria. A 'pooled' Micral-Test result (> or = 15 mg/l) was used to detect mean AER > or = 20 micrograms/min (sensitivity 78%, specificity 77%). This 'pooled cut-off' had already been used for screening on to the study and led to an over-estimate (154 vs. 77) of the true number of microalbuminuric participants on the study. In conclusion, our findings suggest that the Micral-Test strip is not an effective screening tool for microalbuminuria, using the 'pooled' result from two measurements did not improve the sensitivity of the test.
Identifying depression with the PHQ-2: A diagnostic meta-analysis.
Manea, Laura; Gilbody, Simon; Hewitt, Catherine; North, Alice; Plummer, Faye; Richardson, Rachel; Thombs, Brett D; Williams, Bethany; McMillan, Dean
2016-10-01
There is interest in the use of very brief instruments to identify depression because of the advantages they offer in busy clinical settings. The PHQ-2, consisting of two questions relating to core symptoms of depression (low mood and loss of interest or pleasure), is one such instrument. A systematic review was conducted to identify studies that had assessed the diagnostic performance of the PHQ-2 to detect major depression. Embase, MEDLINE, PsychINFO and grey literature databases were searched. Reference lists of included studies and previous relevant reviews were also examined. Studies were included that used the standard scoring system of the PHQ-2, assessed its performance against a gold-standard diagnostic interview and reported data on its performance at the recommended (≥3) or an alternative cut-off point (≥2). After assessing heterogeneity, where appropriate, data from studies were combined using bivariate diagnostic meta-analysis to derive sensitivity, specificity, likelihood ratios and diagnostic odds ratios. 21 studies met inclusion criteria totalling N=11,175 people out of which 1529 had major depressive disorder according to a gold standard. 19 of the 21 included studies reported data for a cut-off point of ≥3. Pooled sensitivity was 0.76 (95% CI =0.68-0.82), pooled specificity was 0.87 (95% CI =0.82-0.90). However there was substantial heterogeneity at this cut-off (I(2)=81.8%). 17 studies reported data on the performance of the measure at cut-off point ≥2. Heterogeneity was I(2)=43.2% pooled sensitivity at this cut-off point was 0.91 (95% CI =0.85-0.94), and pooled specificity was 0.70 (95% CI =0.64-0.76). The generally lower sensitivity of the PHQ-2 at cut-off ≥3 than the original validation study (0.83) suggests that ≥2 may be preferable if clinicians want to ensure that few cases of depression are missed. However, in situations in which the prevalence of depression is low, this may result in an unacceptably high false-positive rate because of the associated modest specificity. These results, however, need to be interpreted with caution given the possibility of selectively reported cut-offs. Copyright © 2016. Published by Elsevier B.V.
Xpert® MTB/RIF assay for pulmonary tuberculosis and rifampicin resistance in adults.
Steingart, Karen R; Schiller, Ian; Horne, David J; Pai, Madhukar; Boehme, Catharina C; Dendukuri, Nandini
2014-01-21
Accurate, rapid detection of tuberculosis (TB) and TB drug resistance is critical for improving patient care and decreasing TB transmission. Xpert® MTB/RIF assay is an automated test that can detect both TB and rifampicin resistance, generally within two hours after starting the test, with minimal hands-on technical time. The World Health Organization (WHO) issued initial recommendations on Xpert® MTB/RIF in early 2011. A Cochrane Review on the diagnostic accuracy of Xpert® MTB/RIF for pulmonary TB and rifampicin resistance was published January 2013. We performed this updated Cochrane Review as part of a WHO process to develop updated guidelines on the use of the test. To assess the diagnostic accuracy of Xpert® MTB/RIF for pulmonary TB (TB detection), where Xpert® MTB/RIF was used as both an initial test replacing microscopy and an add-on test following a negative smear microscopy result.To assess the diagnostic accuracy of Xpert® MTB/RIF for rifampicin resistance detection, where Xpert® MTB/RIF was used as the initial test replacing culture-based drug susceptibility testing (DST).The populations of interest were adults presumed to have pulmonary, rifampicin-resistant or multidrug-resistant TB (MDR-TB), with or without HIV infection. The settings of interest were intermediate- and peripheral-level laboratories. The latter may be associated with primary health care facilities. We searched for publications in any language up to 7 February 2013 in the following databases: Cochrane Infectious Diseases Group Specialized Register; MEDLINE; EMBASE; ISI Web of Knowledge; MEDION; LILACS; BIOSIS; and SCOPUS. We also searched the metaRegister of Controlled Trials (mRCT) and the search portal of the WHO International Clinical Trials Registry Platform to identify ongoing trials. We included randomized controlled trials, cross-sectional studies, and cohort studies using respiratory specimens that allowed for extraction of data evaluating Xpert® MTB/RIF against the reference standard. We excluded gastric fluid specimens. The reference standard for TB was culture and for rifampicin resistance was phenotypic culture-based DST. For each study, two review authors independently extracted data using a standardized form. When possible, we extracted data for subgroups by smear and HIV status. We assessed the quality of studies using QUADAS-2 and carried out meta-analyses to estimate pooled sensitivity and specificity of Xpert® MTB/RIF separately for TB detection and rifampicin resistance detection. For TB detection, we performed the majority of analyses using a bivariate random-effects model and compared the sensitivity of Xpert® MTB/RIF and smear microscopy against culture as reference standard. For rifampicin resistance detection, we undertook univariate meta-analyses for sensitivity and specificity separately to include studies in which no rifampicin resistance was detected. We included 27 unique studies (integrating nine new studies) involving 9557 participants. Sixteen studies (59%) were performed in low- or middle-income countries. For all QUADAS-2 domains, most studies were at low risk of bias and low concern regarding applicability.As an initial test replacing smear microscopy, Xpert® MTB/RIF pooled sensitivity was 89% [95% Credible Interval (CrI) 85% to 92%] and pooled specificity 99% (95% CrI 98% to 99%), (22 studies, 8998 participants: 2953 confirmed TB, 6045 non-TB).As an add-on test following a negative smear microscopy result, Xpert®MTB/RIF pooled sensitivity was 67% (95% CrI 60% to 74%) and pooled specificity 99% (95% CrI 98% to 99%; 21 studies, 6950 participants).For smear-positive, culture-positive TB, Xpert® MTB/RIF pooled sensitivity was 98% (95% CrI 97% to 99%; 21 studies, 1936 participants).For people with HIV infection, Xpert® MTB/RIF pooled sensitivity was 79% (95% CrI 70% to 86%; 7 studies, 1789 participants), and for people without HIV infection, it was 86% (95% CrI 76% to 92%; 7 studies, 1470 participants). Comparison with smear microscopy In comparison with smear microscopy, Xpert® MTB/RIF increased TB detection among culture-confirmed cases by 23% (95% CrI 15% to 32%; 21 studies, 8880 participants).For TB detection, if pooled sensitivity estimates for Xpert® MTB/RIF and smear microscopy are applied to a hypothetical cohort of 1000 patients where 10% of those with symptoms have TB, Xpert® MTB/RIF will diagnose 88 cases and miss 12 cases, whereas sputum microscopy will diagnose 65 cases and miss 35 cases. Rifampicin resistance For rifampicin resistance detection, Xpert® MTB/RIF pooled sensitivity was 95% (95% CrI 90% to 97%; 17 studies, 555 rifampicin resistance positives) and pooled specificity was 98% (95% CrI 97% to 99%; 24 studies, 2411 rifampicin resistance negatives). Among 180 specimens with nontuberculous mycobacteria (NTM), Xpert® MTB/RIF was positive in only one specimen that grew NTM (14 studies, 2626 participants).For rifampicin resistance detection, if the pooled accuracy estimates for Xpert® MTB/RIF are applied to a hypothetical cohort of 1000 individuals where 15% of those with symptoms are rifampicin resistant, Xpert® MTB/RIF would correctly identify 143 individuals as rifampicin resistant and miss eight cases, and correctly identify 833 individuals as rifampicin susceptible and misclassify 17 individuals as resistant. Where 5% of those with symptoms are rifampicin resistant, Xpert® MTB/RIF would correctly identify 48 individuals as rifampicin resistant and miss three cases and correctly identify 931 individuals as rifampicin susceptible and misclassify 19 individuals as resistant. In adults thought to have TB, with or without HIV infection, Xpert® MTB/RIF is sensitive and specific. Compared with smear microscopy, Xpert® MTB/RIF substantially increases TB detection among culture-confirmed cases. Xpert® MTB/RIF has higher sensitivity for TB detection in smear-positive than smear-negative patients. Nonetheless, this test may be valuable as an add-on test following smear microscopy in patients previously found to be smear-negative. For rifampicin resistance detection, Xpert® MTB/RIF provides accurate results and can allow rapid initiation of MDR-TB treatment, pending results from conventional culture and DST. The tests are expensive, so current research evaluating the use of Xpert® MTB/RIF in TB programmes in high TB burden settings will help evaluate how this investment may help start treatment promptly and improve outcomes.
Fanti, Stefano; Minozzi, Silvia; Castellucci, Paolo; Balduzzi, Sara; Herrmann, Ken; Krause, Bernd Joachim; Oyen, Wim; Chiti, Arturo
2016-01-01
For the last decade PET and PET/CT with (11)C-choline have been proposed for the evaluation of prostate cancer (PC), but the diagnostic performance of (11)C-choline PET/CT is still a matter of debate. We performed a comprehensive review of the most important clinical application of (11)C-choline PET, restaging of patients with biochemical relapse, following a rigorous methodological approach and including assessment of the risk of bias. We conducted a systematic review and meta-analysis of the literature assessing (11)C-choline PET/CT for its accuracy in the diagnosis and ability to detect the site of recurrence of PC in the restaging of patients with biochemical recurrence after initial treatment with curative intent. We performed a comprehensive literature search of PubMed and the Cochrane Library to determine the accuracy for the detection of the site of recurrence (prostate bed recurrences, metastatic spread to locoregional pelvic lymph nodes or distant metastases). Only studies with a reference standard (for prostatic bed histopathology, for histopathology or biopsy of distant metastases or a composite reference standard with clinical follow-up of at least 12 months, correlative imaging and clinical data) were included. Overall 425 studies were retrieved, of which 43 were judged as potentially relevant and 29 with 2,686 participants were finally included. Of these 29 studies, 18 reported results for any relapse, All 18 studies, with a total of 2,126 participants, reported detection rates. The pooled rate was 62 % (95 % CI 53 - 71 %). Of the 18 studies, 12 with 1,270 participants reported useful data to derive sensitivity and specificity. The pooled sensitivity was 89 % (95 % CI 83 - 93 %) and the pooled specificity was 89 % (95 % CI 73 - 96 %). Of 11 studies reporting results for local relapse, 9 with 993 participants reported detection rates. The pooled rate was 27 % (95 % CI 16 - 38 %). Six studies with 491 participants reported sensitivity and specificity. The pooled sensitivity was 61 % (95 % CI 40 - 80 %) and the pooled specificity was 97 % (95 % CI 87 - 99 %). Ten studies reported results for lymph nodes and distant metastases. For nodal disease, 7 studies with 752 participants reported detection rates. The pooled rate was 36 % (95 % CI 22 - 50 %). For bone metastases, 8 studies with 775 participants reported detection rates. The pooled rate was 25 % (95 % CI 16 - 34 %). There is a significant amount of (11)C-choline PET data published showing a high degree of consistency in inclusion criteria, acquisition protocols and scan interpretation criteria. Furthermore, the quality of the data derived limited to the same standard of reference was acceptable. Despite a high variability in the observed prevalence of any relapse, the diagnostic performance of (11)C-choline PET was in line with previous meta-analyses. Our data confirm the very good accuracy of (11)C-choline PET for detection of lymph node metastases and/or distant lesions in a single examination in patients with biochemical relapse.
Kim, Jun H; Lee, Kyung H; Kim, Kyoung-Tae; Ahn, Hyeong S; Kim, Yeo J; Lee, Ha Y; Jeon, Yong S
2016-01-01
Objective: To compare the diagnostic accuracy of digital tomosynthesis (DTS) with that of chest radiography for the detection of pulmonary nodules by meta-analysis. Methods: A systematic literature search was performed to identify relevant original studies from 1 January 1 1976 to 31 August 31 2016. The quality of included studies was assessed by quality assessment of diagnostic accuracy studies-2. Per-patient data were used to calculate the sensitivity and specificity and per-lesion data were used to calculate the detection rate. Summary receiver-operating characteristic curves were drawn for pulmonary nodule detection. Results: 16 studies met the inclusion criteria. 1017 patients on a per-patient basis and 2159 lesions on a per-lesion basis from 16 eligible studies were evaluated. The pooled patient-based sensitivity of DTS was 0.85 [95% confidence interval (CI) 0.83–0.88] and the specificity was 0.95 (0.93–0.96). The pooled sensitivity and specificity of chest radiography were 0.47 (0.44–0.51) and 0.37 (0.34–0.40), respectively. The per-lesion detection rate was 2.90 (95% CI 2.63–3.19). Conclusion: DTS has higher diagnostic accuracy than chest radiography for detection of pulmonary nodules. Chest radiography has low sensitivity but similar specificity, comparable with that of DTS. Advances in knowledge: DTS has higher diagnostic accuracy than chest radiography for the detection of pulmonary nodules. PMID:27759428
Liu, Tao; Xu, Wen; Yan, Wei-Li; Ye, Ming; Bai, Yong-Rui; Huang, Gang
2007-12-01
To perform a systematic review to compare FDG-PET, CT, and MRI imaging for diagnosis of local residual or recurrent nasopharyngeal carcinoma. MEDLINE, EMBASE, the CBMdisc databases and some other databases were searched for relevant original articles published from January 1990 to June 2007. Inclusion criteria were as follows: Articles were reported in English or Chinese; FDG-PET, CT, or MRI was used to detect local residual or recurrent nasopharyngeal carcinoma; histopathologic analysis and/or close clinical and imaging follow-up for at least 6 months were the reference standard. Two reviewers independently extracted data. A software called "Meta-DiSc" was used to obtain pooled estimates of sensitivity, specificity, diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curves, and the Q* index. Twenty-one articles fulfilled all inclusion criteria. The pooled sensitivity estimates for PET (95%) were significantly higher than CT (76%) (P<0.001) and MRI (78%) (P<0.001). The pooled specificity estimates for PET (90%) were significantly higher than CT (59%) (P<0.001) and MRI (76%) (P<0.001). The pooled DOR estimates for PET (96.51) were significantly higher than CT (7.01) (P<0.001) and MRI (8.68) (P<0.001). SROC curve for FDG-PET showed better diagnostic accuracy than CT and MRI. The Q* index for PET (0.92) was significantly higher than CT (0.72) (P<0.001) and MRI (0.76) (P<0.01). For PET, the sensitivity and diagnostic OR for using qualitative analysis were significantly higher than using both qualitative and quantitative analyses (P<0.01). For CT, the sensitivity, specificity, diagnostic OR, and the Q* index for dual-section helical and multi-section helical were all significantly higher than nonhelical and single-section helical (P<0.01). And the sensitivity for 'section thickness <5 mm' was significantly lower than ' =5 mm' (P<0.01), while the specificity was significantly higher (P<0.01). For MRI, there were no significant differences found between magnetic field strength <1.5 and > or =1.5 T (P>0.05). FDG-PET was the best modality for diagnosis of local residual or recurrent nasopharyngeal carcinoma. The type of analysis for PET imaging and the section thickness for CT would affect the diagnostic results. Dual-section helical and multi-section helical CT were better than nonhelical and single-section helical CT.
Tu, S; Rosenthal, M; Wang, D; Huang, J; Chen, Y
2016-09-01
Controversies about the performance of conventional prenatal screening using maternal serum and ultrasound markers (PSMSUM) in detecting Down syndrome (DS) have been raised as a result of a recently available noninvasive prenatal test based on cell-free fetal DNA sequencing. To evaluate the screening performance of PSMSUM in detecting DS in Chinese women. An exhaustive literature search of MEDLINE, Embase, the Cochrane Library, ISI Web of Science and China BioMedical Disc. Primary studies, published from January 2004 to November 2014, which examined the screening accuracy of PSMSUM in pregnant Chinese women, compared with a reference standard, either chromosomal verification or inspection of the newborn. Data were extracted as screening positive/negative results for Down and non-Down syndrome pregnancies, allowing estimation of sensitivities and specificities. Risks of bias within and across studies were assessed. Screening accuracy measures were pooled using a bivariate random effects regression model. Seventy-eight studies, involving six categories of PSMSUM, were included. Second-trimester double serum [pooled sensitivity (SEN) = 0.80, pooled specificity (SPE) = 0.95] and triple-serum (pooled SEN = 0.79, pooled SPE = 0.96) screening were the predominant PSMSUM methods. The screening performances of these methods achieved the national standard but varied enormously across studies. First-trimester combined screening (pooled SEN = 0.92, pooled SPE = 0.93) and second-trimester quadruple serum screening (median SEN = 0.86, median SPE = 0.96) performed better, but were rarely used. Second-trimester maternal serum screening has the potential to achieve satisfactory screening performance in middle- and low-income countries. The reported enormous range in screening performance of second-trimester PSMSUM calls for urgent implementation of methods for performance optimization. Meta-analysis results show good accuracy of maternal serum and ultrasound screening for trisomy 21 in Chinese women. © 2016 Royal College of Obstetricians and Gynaecologists.
Potential diagnostic value of serum p53 antibody for detecting colorectal cancer: A meta-analysis.
Meng, Rongqin; Wang, Yang; He, Liang; He, Yuanqing; Du, Zedong
2018-04-01
Numerous studies have assessed the diagnostic value of serum p53 (s-p53) antibody in patients with colorectal cancer (CRC); however, results remain controversial. The present study aimed to comprehensively and quantitatively summarize the potential diagnostic value of s-p53 antibody in CRC. The present study utilized databases, including PubMed and EmBase, systematically regarding s-p53 antibody diagnosis in CRC, accessed on and prior to 31 July 2016. The quality of all the included studies was assessed using quality assessment of studies of diagnostic accuracy (QUADAS). The result of pooled sensitivity, pooled specificity, positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were analyzed and compared with overall accuracy measures using diagnostic odds ratios (DORs) and area under the curve (AUC) analysis. Publication bias and heterogeneity were also assessed. A total of 11 trials that enrolled a combined 3,392 participants were included in the meta-analysis. Approximately 72.73% (8/11) of the included studies were of high quality (QUADAS score >7), and all were retrospective case-control studies. The pooled sensitivity was 0.19 [95% confidence interval (CI), 0.18-0.21] and pooled specificity was 0.93 (95% CI, 0.92-0.94). Results also demonstrated a PLR of 4.56 (95% CI, 3.27-6.34), NLR of 0.78 (95% CI, 0.71-0.85) and DOR of 6.70 (95% CI, 4.59-9.76). The symmetrical summary receiver operating characteristic curve was 0.73. Furthermore, no evidence of publication bias or heterogeneity was observed in the meta-analysis. Meta-analysis data indicated that s-p53 antibody possesses potential diagnostic value for CRC. However, discrimination power was somewhat limited due to the low sensitivity.
Ramos, Enrique; Levinson, Benjamin T; Chasnoff, Sara; Hughes, Andrew; Young, Andrew L; Thornton, Katherine; Li, Allie; Vallania, Francesco L M; Province, Michael; Druley, Todd E
2012-12-06
Rare genetic variation in the human population is a major source of pathophysiological variability and has been implicated in a host of complex phenotypes and diseases. Finding disease-related genes harboring disparate functional rare variants requires sequencing of many individuals across many genomic regions and comparing against unaffected cohorts. However, despite persistent declines in sequencing costs, population-based rare variant detection across large genomic target regions remains cost prohibitive for most investigators. In addition, DNA samples are often precious and hybridization methods typically require large amounts of input DNA. Pooled sample DNA sequencing is a cost and time-efficient strategy for surveying populations of individuals for rare variants. We set out to 1) create a scalable, multiplexing method for custom capture with or without individual DNA indexing that was amenable to low amounts of input DNA and 2) expand the functionality of the SPLINTER algorithm for calling substitutions, insertions and deletions across either candidate genes or the entire exome by integrating the variant calling algorithm with the dynamic programming aligner, Novoalign. We report methodology for pooled hybridization capture with pre-enrichment, indexed multiplexing of up to 48 individuals or non-indexed pooled sequencing of up to 92 individuals with as little as 70 ng of DNA per person. Modified solid phase reversible immobilization bead purification strategies enable no sample transfers from sonication in 96-well plates through adapter ligation, resulting in 50% less library preparation reagent consumption. Custom Y-shaped adapters containing novel 7 base pair index sequences with a Hamming distance of ≥2 were directly ligated onto fragmented source DNA eliminating the need for PCR to incorporate indexes, and was followed by a custom blocking strategy using a single oligonucleotide regardless of index sequence. These results were obtained aligning raw reads against the entire genome using Novoalign followed by variant calling of non-indexed pools using SPLINTER or SAMtools for indexed samples. With these pipelines, we find sensitivity and specificity of 99.4% and 99.7% for pooled exome sequencing. Sensitivity, and to a lesser degree specificity, proved to be a function of coverage. For rare variants (≤2% minor allele frequency), we achieved sensitivity and specificity of ≥94.9% and ≥99.99% for custom capture of 2.5 Mb in multiplexed libraries of 22-48 individuals with only ≥5-fold coverage/chromosome, but these parameters improved to ≥98.7 and 100% with 20-fold coverage/chromosome. This highly scalable methodology enables accurate rare variant detection, with or without individual DNA sample indexing, while reducing the amount of required source DNA and total costs through less hybridization reagent consumption, multi-sample sonication in a standard PCR plate, multiplexed pre-enrichment pooling with a single hybridization and lesser sequencing coverage required to obtain high sensitivity.
A new serotyping method for Klebsiella species: development of the technique.
Riser, E; Noone, P; Poulton, T A
1976-01-01
A new serotyping method for Klebsiella species using indirect immunofluorescence is described. Nonspecific fluorescence has been minimized by carrying out the capsular antigen-antibody reaction at pH 9.0. Commercial antisera have been tested with the 72 antigenic types of Klebsiella, and appropriate dilutions of each pool and specific antisera have been proposed for use in routine typing. Dilutions were chosen to allow strong fluorescence with each type and its specific antiserum and minimal fluorescence with cross reacting antisera. Where the pool antisera gave a weak reaction for one or more of the component types, it is recommended that the specific antisera for these types be added to the pool dilution. The few remaining cross reactions, with the pool and specific antisera in test dilution, are listed in a table. The unique cross reacting patterns of particular types have been found to be useful in identification. Typing Klebsiella by the fluorescent antibody technique is easy to perform and interpret; the results are reproducible, and it is less expensive than the existing capsular swelling method as it is more sensitive and requires less concentrated antisera. This new method of typing should facilitate detailed epidemiological studies of the mode of transmission of Klebsiella species in hospitals and thus allow more effective infection control measures to be instituted. Images PMID:777042
Biaoxue, Rong; Shuanying, Yang
2018-01-01
Many studies have evaluated the accuracy of EGFR mutation status in blood against that in tumor tissues as the reference. We conducted this systematic review and meta-analysis to assess whether blood can be used as a substitute for tumor tissue in detecting EGFR mutations. Investigations that provided data on EGFR mutation status in blood were searched in the databases of Medline, Embase, Ovid Technologies and Web of Science. The detect efficiency of EGFR mutations in paired blood and tissues was compared using a random-effects model of meta-analysis. Pooled sensitivity and specificity and diagnostic accuracy were calculated by receiver operating characteristic curve. A total of 19 studies with 2,922 individuals were involved in this meta-analysis. The pooled results showed the positive detection rate of EGFR mutations in lung cancer tissues was remarkably higher than that of paired blood samples (odds ratio [OR] = 1.47, p<0.001). The pooled sensitivity and specificity of blood were 0.65 and 0.91, respectively, and the area under the receiver operating characteristic curve was 0.89. Although blood had a better specificity for detecting EGFR mutations, the absence of blood positivity should not necessarily be construed as confirmed negativity. Patients with negative results for blood should decidedly undergo further biopsies to ascertain EGFR mutations.
Variation of a test's sensitivity and specificity with disease prevalence.
Leeflang, Mariska M G; Rutjes, Anne W S; Reitsma, Johannes B; Hooft, Lotty; Bossuyt, Patrick M M
2013-08-06
Anecdotal evidence suggests that the sensitivity and specificity of a diagnostic test may vary with disease prevalence. Our objective was to investigate the associations between disease prevalence and test sensitivity and specificity using studies of diagnostic accuracy. We used data from 23 meta-analyses, each of which included 10-39 studies (416 total). The median prevalence per review ranged from 1% to 77%. We evaluated the effects of prevalence on sensitivity and specificity using a bivariate random-effects model for each meta-analysis, with prevalence as a covariate. We estimated the overall effect of prevalence by pooling the effects using the inverse variance method. Within a given review, a change in prevalence from the lowest to highest value resulted in a corresponding change in sensitivity or specificity from 0 to 40 percentage points. This effect was statistically significant (p < 0.05) for either sensitivity or specificity in 8 meta-analyses (35%). Overall, specificity tended to be lower with higher disease prevalence; there was no such systematic effect for sensitivity. The sensitivity and specificity of a test often vary with disease prevalence; this effect is likely to be the result of mechanisms, such as patient spectrum, that affect prevalence, sensitivity and specificity. Because it may be difficult to identify such mechanisms, clinicians should use prevalence as a guide when selecting studies that most closely match their situation.
Variation of a test’s sensitivity and specificity with disease prevalence
Leeflang, Mariska M.G.; Rutjes, Anne W.S.; Reitsma, Johannes B.; Hooft, Lotty; Bossuyt, Patrick M.M.
2013-01-01
Background: Anecdotal evidence suggests that the sensitivity and specificity of a diagnostic test may vary with disease prevalence. Our objective was to investigate the associations between disease prevalence and test sensitivity and specificity using studies of diagnostic accuracy. Methods: We used data from 23 meta-analyses, each of which included 10–39 studies (416 total). The median prevalence per review ranged from 1% to 77%. We evaluated the effects of prevalence on sensitivity and specificity using a bivariate random-effects model for each meta-analysis, with prevalence as a covariate. We estimated the overall effect of prevalence by pooling the effects using the inverse variance method. Results: Within a given review, a change in prevalence from the lowest to highest value resulted in a corresponding change in sensitivity or specificity from 0 to 40 percentage points. This effect was statistically significant (p < 0.05) for either sensitivity or specificity in 8 meta-analyses (35%). Overall, specificity tended to be lower with higher disease prevalence; there was no such systematic effect for sensitivity. Interpretation: The sensitivity and specificity of a test often vary with disease prevalence; this effect is likely to be the result of mechanisms, such as patient spectrum, that affect prevalence, sensitivity and specificity. Because it may be difficult to identify such mechanisms, clinicians should use prevalence as a guide when selecting studies that most closely match their situation. PMID:23798453
Diagnostic testing for celiac disease among patients with abdominal symptoms: a systematic review.
van der Windt, Daniëlle A W M; Jellema, Petra; Mulder, Chris J; Kneepkens, C M Frank; van der Horst, Henriëtte E
2010-05-05
The symptoms and consequences of celiac disease usually resolve with a lifelong gluten-free diet. However, clinical presentation is variable and most patients presenting with abdominal symptoms in primary care will not have celiac disease and unnecessary diagnostic testing should be avoided. To summarize evidence on the performance of diagnostic tests for identifying celiac disease in adults presenting with abdominal symptoms in primary care or similar settings. A literature search via MEDLINE (beginning in January 1966) and EMBASE (beginning in January 1947) through December 2009 and a manual search of references for additional relevant studies. Diagnostic studies were selected if they had a cohort or nested case-control design, enrolled adults presenting with nonacute abdominal symptoms, the prevalence of celiac disease was 15% or less, and the tests used included gastrointestinal symptoms or serum antibody tests. Quality assessment using the Quality Assessment of Diagnostic Accuracy Studies tool and data extraction were performed by 2 reviewers independently. Sensitivities and specificities were calculated for each study and pooled estimates were computed using bivariate analysis if there was clinical and statistical homogeneity. Sixteen studies were included in the review (N = 6085 patients). The performance of abdominal symptoms varied widely. The sensitivity of diarrhea, for example, ranged from 0.27 to 0.86 and specificity from 0.21 to 0.86. Pooled estimates for IgA antiendomysial antibodies (8 studies) were 0.90 (95% confidence interval [CI], 0.80-0.95) for sensitivity and 0.99 (95% CI, 0.98-1.00) for specificity (positive likelihood ratio [LR] of 171 and negative LR of 0.11). Pooled estimates for IgA antitissue transglutaminase antibodies (7 studies) were 0.89 (95% CI, 0.82-0.94) and 0.98 (95% CI, 0.95-0.99), respectively (positive LR of 37.7 and negative LR of 0.11). The IgA and IgG antigliadin antibodies showed variable results, especially for sensitivity (range, 0.46-0.87 and range, 0.25-0.93, respectively). One recent study using diamidated gliadin peptides showed good specificity (> or = 0.94), but evidence is limited in this target population. Among adult patients presenting with abdominal symptoms in primary care or other unselected populations, IgA antitissue transglutaminase antibodies and IgA antiendomysial antibodies have high sensitivity and specificity for diagnosing celiac disease.
Jiang, Sha-Yi; Yang, Jing-Wei; Shao, Jing-Bo; Liao, Xue-Lian; Lu, Zheng-Hua; Jiang, Hui
2016-05-01
In this meta-analysis, we evaluated the diagnostic role of Epstein-Barr virus deoxyribonucleic acid detection and quantitation in the serum of pediatric and young adult patients with infectious mononucleosis. The primary outcome of this meta-analysis was the sensitivity and specificity of Epstein-Barr virus (EBV) deoxyribonucleic acid (DNA) detection and quantitation using polymerase chain reaction (PCR). A systematic review and meta-analysis was performed by searching for articles that were published through September 24, 2014 in the following databases: Medline, Cochrane, EMBASE, and Google Scholar. The following keywords were used for the search: "Epstein-Barr virus," "infectious mononucleosis," "children/young adults/infant/pediatric," and "polymerase chain reaction or PCR." Three were included in this analysis. We found that for detection by PCR, the pooled sensitivity for detecting EBV DNA was 77% (95%CI, 66-86%) and the pooled specificity for was 98% (95%CI, 93-100%). Our findings indicate that this PCR-based assay has high specificity and good sensitivity for detecting of EBV DNA, indicating it may useful for identifying patients with infectious mononucleosis. This assay may also be helpful to identify young athletic patients or highly physically active pediatric patients who are at risk for a splenic rupture due to acute infectious mononucleosis. © 2015 Wiley Periodicals, Inc.
Zheng, Jun; Yu, Zhiyuan; Guo, Rui; Li, Hao; You, Chao; Ma, Lu
2018-04-27
Hematoma expansion is related to unfavorable prognosis in intracerebral hemorrhage (ICH). The black hole sign is a novel marker on non-contrast computed tomography for predicting hematoma expansion. However, its predictive values are different in previous studies. Thus, this meta-analysis was conducted to evaluate the predictive significance of the black hole sign for hematoma expansion in ICH. A systematic literature search was performed. Original researches on the association between the black hole sign and hematoma expansion in ICH were included. Sensitivity and specificity were pooled to assess the predictive accuracy. Summary receiver operating characteristics curve (SROC) was developed. Deeks' funnel plot asymmetry test was used to assess the publication bias. Five studies with a total of 1495 patients were included in this study. The pooled sensitivity and specificity of the black hole sign for predicting hematoma expansion were 0.30 and 0.91, respectively. The area under the curve was 0.78 in SROC curve. There was no significant publication bias. This meta-analysis shows that the black hole sign is a helpful imaging marker for predicting hematoma expansion in ICH. Although the black hole sign has a relatively low sensitivity, its specificity is relatively high. Copyright © 2018 Elsevier Inc. All rights reserved.
Li, Zhanzhan; Zhou, Qin; Li, Yanyan; Yan, Shipeng; Fu, Jun; Huang, Xinqiong; Shen, Liangfang
2017-02-28
We conducted a meta-analysis to evaluate the diagnostic values of mean cerebral blood volume for recurrent and radiation injury in glioma patients. We performed systematic electronic searches for eligible study up to August 8, 2016. Bivariate mixed effects models were used to estimate the combined sensitivity, specificity, positive likelihood ratios, negative likelihood ratios, diagnostic odds ratios and their 95% confidence intervals (CIs). Fifteen studies with a total number of 576 participants were enrolled. The pooled sensitivity and specificity of diagnostic were 0.88 (95%CI: 0.82-0.92) and 0.85 (95%CI: 0.68-0.93). The pooled positive likelihood ratio is 5.73 (95%CI: 2.56-12.81), negative likelihood ratio is 0.15 (95%CI: 0.10-0.22), and the diagnostic odds ratio is 39.34 (95%CI:13.96-110.84). The summary receiver operator characteristic is 0.91 (95%CI: 0.88-0.93). However, the Deek's plot suggested publication bias may exist (t=2.30, P=0.039). Mean cerebral blood volume measurement methods seems to be very sensitive and highly specific to differentiate recurrent and radiation injury in glioma patients. The results should be interpreted with caution because of the potential bias.
Arbyn, Marc; Buntinx, Frank; Van Ranst, Marc; Paraskevaidis, Evangelos; Martin-Hirsch, Pierre; Dillner, Joakim
2004-02-18
The appropriate management of women with minor cytologic lesions in their cervix is unclear. We performed a meta-analysis to assess the accuracy of human papillomavirus (HPV) DNA testing as an alternative to repeat cytology in women who had equivocal results on a previous Pap smear. Data were extracted from articles published between 1992 and 2002 that contained results of virologic and cytologic testing followed by colposcopically directed biopsy in women with an index smear showing atypical cells of undetermined significance (ASCUS). Fifteen studies were identified in which HPV triage and the histologic outcome (presence or absence of a cervical intraepithelial neoplasia of grade II or worse [CIN2+]) was documented. Nine, seven, and two studies also documented the accuracy of repeat cytology when the cutoff for abnormal cytology was set at a threshold of ASCUS or worse, low-grade squamous intraepithelial lesion (LSIL) or worse, or high-grade squamous intraepithelial lesion (HSIL) or worse, respectively. Random-effects models were used for pooling of accuracy parameters in case of interstudy heterogeneity. Differences in accuracy were assessed by pooling the ratio of the sensitivity (or specificity) of HPV testing to that of repeat cytology. The sensitivity and specificity were 84.4% (95% confidence interval [CI] = 77.6% to 91.1%) and 72.9% (95% CI = 62.5% to 83.3%), respectively, for HPV testing overall and 94.8% (95% CI = 92.7% to 96.9%) and 67.3% (95% CI = 58.2% to 76.4%), respectively, for HPV testing in the eight studies that used the Hybrid Capture II assay. Sensitivity and specificity of repeat cytology at a threshold for abnormal cytology of ASCUS or worse was 81.8% (95% CI = 73.5% to 84.3%) and 57.6% (95% CI = 49.5% to 65.7%), respectively. Repeat cytology that used higher cytologic thresholds yielded substantially lower sensitivity but higher specificity than triage with the Hybrid Capture II assay. The ratio of the sensitivity of the Hybrid Capture II assay to that of repeat cytology at a threshold of ASCUS or worse pooled from the four studies that used both triage tests was 1.16 (95% CI = 1.04 to 1.29). The specificity ratio was not statistically different from unity. The published literature indicates that the Hybrid Capture II assay has improved accuracy (higher sensitivity, similar specificity) than the repeat Pap smear using the threshold of ASCUS for an outcome of CIN2+ among women with equivocal cytologic results. The sensitivity of triage at higher cytologic cutoffs is poor.
Ultrasound for diagnosing radiographically occult scaphoid fracture.
Kwee, Robert M; Kwee, Thomas C
2018-04-04
To systematically review the literature on the performance of ultrasound in diagnosing radiographically occult scaphoid fracture. A systematic search was performed in the MEDLINE and Embase databases. Original studies investigating the performance of ultrasound in diagnosing radiographically occult scaphoid fracture in more than 10 patients were eligible for inclusion. Studies that included both radiographically apparent and occult scaphoid fractures (at initial radiography) were only included if independent data on radiographically occult fractures were reported. Methodological quality of the studies included was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Accuracy data were extracted. Sensitivity and specificity were pooled with a bivariate random-effects model. The inclusion criteria were met by 7 studies; total sample size comprised 314 patients. All studies, except 1, included cortical disruption of the scaphoid in their diagnostic criteria. The sensitivity and specificity of ultrasound in diagnosing radiographically occult scaphoid fracture ranged from 77.8% to 100% and from 71.4% to 100% respectively, with pooled estimates of 85.6% (95% CI: 73.9%, 92.6%) and 83.3% % (95% CI: 72.0%, 90.6%) respectively. Exclusion of two studies with a high risk of bias in any QUADAS-2 domain did not affect the pooled results. Ultrasound can diagnose radiographically occult scaphoid fracture with a fairly high degree of accuracy. Because of its relatively low costs and fairly high sensitivity, ultrasound seems more cost-effective than empiric cast immobilization and may be used when CT and MRI are not readily available.
Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik
2016-11-01
To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.
Ablordeppey, Enyo A; Drewry, Anne M; Beyer, Alexander B; Theodoro, Daniel L; Fowler, Susan A; Fuller, Brian M; Carpenter, Christopher R
2017-04-01
We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared with chest radiography. PubMed, Embase, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov. Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2 × 2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, interrater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Fifteen studies with 1,553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 (0.77-0.86) and 0.98 (0.97-0.99), respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 (14.72-65.78) and 0.25 (0.13-0.47). The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than chest radiography.
Cong, Lihong; Wang, Shikun; Gao, Teng; Hu, Likuan
2016-12-01
We want to review the value of 18-fluoro-deoxy-glucose positron emission tomography for response prediction of primary tumor in patients with esophageal cancer during or after neoadjuvant chemoradiotherapy. Studies were searched in Pubmed, Embase and Cochrane Library with specific search strategy. The published articles were included according to the criteria established in advance. The included studies were divided into two groups according to the time of the repeat positron emission tomography: during (Group A) or after neoadjuvant chemoradiotherapy (Group B). The studies that performed the repeat positron emission tomography after neoadjuvant chemoradiotherapy were graded Quality Assessment of Diagnostic Accuracy Studies. The pooled sensitivity, specificity and diagnostic odds ratio were obtained for both groups on the basis of no-existing of threshold effect. Fifteen studies were included in the present study. The threshold effect did not exist in both groups. The pooled sensitivity, specificity and diagnostic odds ratio were 85%, 59%, 6.82 with 95% confidence interval 76-91%, 48-69%, 2.25-20.72 in Group A. The equivalent values were 67%, 69%, 6.34 with 95% confidence interval 60-73%, 63-74%, 2.08-19.34 in Group B. The pooled sensitivity was 90% in four studies that enrolled patients with esophageal squamous cell carcinoma merely in Group B. According to the present data, positron emission tomography should not be used routinely to guide treatment strategy in esophageal cancer patients. We speculated that positron emission tomography could be used as a tool to predict treatment response after neoadjuvant chemoradiotherapy in patients with esophageal squamous cell carcinoma. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Ultrasound for Distal Forearm Fracture: A Systematic Review and Diagnostic Meta-Analysis
Douma-den Hamer, Djoke; Blanker, Marco H.; Edens, Mireille A.; Buijteweg, Lonneke N.; Boomsma, Martijn F.; van Helden, Sven H.; Mauritz, Gert-Jan
2016-01-01
Study Objective To determine the diagnostic accuracy of ultrasound for detecting distal forearm fractures. Methods A systematic review and diagnostic meta-analysis was performed according to the PRISMA statement. We searched MEDLINE, Web of Science and the Cochrane Library from inception to September 2015. All prospective studies of the diagnostic accuracy of ultrasound versus radiography as the reference standard were included. We excluded studies with a retrospective design and those with evidence of verification bias. We assessed the methodological quality of the included studies with the QUADAS-2 tool. We performed a meta-analysis of studies evaluating ultrasound to calculate the pooled sensitivity and specificity with 95% confidence intervals (CI95%) using a bivariate model with random effects. Subgroup and sensitivity analysis were used to examine the effect of methodological differences and other study characteristics. Results Out of 867 publications we included 16 studies with 1,204 patients and 641 fractures. The pooled test characteristics for ultrasound were: sensitivity 97% (CI95% 93–99%), specificity 95% (CI95% 89–98%), positive likelihood ratio (LR) 20.0 (8.5–47.2) and negative LR 0.03 (0.01–0.08). The corresponding pooled diagnostic odds ratio (DOR) was 667 (142–3,133). Apparent differences were shown for method of viewing, with the 6-view method showing higher specificity, positive LR, and DOR, compared to the 4-view method. Conclusion The present meta-analysis showed that ultrasound has a high accuracy for the diagnosis of distal forearm fractures in children when used by proper viewing method. Based on this, ultrasound should be considered a reliable alternative, which has the advantages of being radiation free. PMID:27196439
Weng, Hsu-Huei; Noll, Kyle R; Johnson, Jason M; Prabhu, Sujit S; Tsai, Yuan-Hsiung; Chang, Sheng-Wei; Huang, Yen-Chu; Lee, Jiann-Der; Yang, Jen-Tsung; Yang, Cheng-Ta; Tsai, Ying-Huang; Yang, Chun-Yuh; Hazle, John D; Schomer, Donald F; Liu, Ho-Ling
2018-02-01
Purpose To compare functional magnetic resonance (MR) imaging for language mapping (hereafter, language functional MR imaging) with direct cortical stimulation (DCS) in patients with brain tumors and to assess factors associated with its accuracy. Materials and Methods PubMed/MEDLINE and related databases were searched for research articles published between January 2000 and September 2016. Findings were pooled by using bivariate random-effects and hierarchic summary receiver operating characteristic curve models. Meta-regression and subgroup analyses were performed to evaluate whether publication year, functional MR imaging paradigm, magnetic field strength, statistical threshold, and analysis software affected classification accuracy. Results Ten articles with a total of 214 patients were included in the analysis. On a per-patient basis, the pooled sensitivity and specificity of functional MR imaging was 44% (95% confidence interval [CI]: 14%, 78%) and 80% (95% CI: 54%, 93%), respectively. On a per-tag basis (ie, each DCS stimulation site or "tag" was considered a separate data point across all patients), the pooled sensitivity and specificity were 67% (95% CI: 51%, 80%) and 55% (95% CI: 25%, 82%), respectively. The per-tag analysis showed significantly higher sensitivity for studies with shorter functional MR imaging session times (P = .03) and relaxed statistical threshold (P = .05). Significantly higher specificity was found when expressive language task (P = .02), longer functional MR imaging session times (P < .01), visual presentation of stimuli (P = .04), and stringent statistical threshold (P = .01) were used. Conclusion Results of this study showed moderate accuracy of language functional MR imaging when compared with intraoperative DCS, and the included studies displayed significant methodologic heterogeneity. © RSNA, 2017 Online supplemental material is available for this article.
Gans, Sarah L; Atema, Jasper J; van Dieren, Susan; Groot Koerkamp, Bas; Boermeester, Marja A
2015-07-01
Infectious complications occur frequently after major abdominal surgery and have a major influence on patient outcome and hospital costs. A marker that can rule out postoperative infectious complications (PICs) could aid patient selection for safe and early hospital discharge. C-reactive protein (CRP) is a widely available, fast, and cheap marker that might be of value in detecting PIC. Present meta-analysis evaluates the diagnostic value of CRP to rule out PIC following major abdominal surgery, aiding patient selection for early discharge. A systematic literature search of Medline, PubMed, and Cochrane was performed identifying all prospective studies evaluating the diagnostic value of CRP after abdominal surgery. Meta-analysis was performed according to the PRISMA statement. Twenty-two studies were included for qualitative analysis of which 16 studies were eligible for meta-analysis, representing 2215 patients. Most studies analyzed the value of CRP in colorectal surgery (eight studies). The pooled negative predictive value (NPV) improved each day after surgery up to 90% at postoperative day (POD) 3 for a pooled CRP cutoff of 159 mg/L (range 92-200). Maximum predictive values for PICs were reached on POD 5 for a pooled CRP cutoff of 114 mg/L (range 48-150): a pooled sensitivity of 86% (95% confidence interval (CI) 79-91%), specificity of 86% (95% CI 75-92%), and a positive predictive value of 64% (95% CI 49-77%). The pooled sensitivity and specificity were significantly higher on POD 5 than on other PODs (p < 0.001). Infectious complications after major abdominal surgery are very unlikely in patients with a CRP below 159 mg/L on POD 3. This can aid patient selection for safe and early hospital discharge and prevent overuse of imaging.
Multidimensional severity assessment in bronchiectasis: an analysis of seven European cohorts
McDonnell, M J; Aliberti, S; Goeminne, P C; Dimakou, K; Zucchetti, S C; Davidson, J; Ward, C; Laffey, J G; Finch, S; Pesci, A; Dupont, L J; Fardon, T C; Skrbic, D; Obradovic, D; Cowman, S; Loebinger, M R; Rutherford, R M; De Soyza, A; Chalmers, J D
2016-01-01
Introduction Bronchiectasis is a multidimensional disease associated with substantial morbidity and mortality. Two disease-specific clinical prediction tools have been developed, the Bronchiectasis Severity Index (BSI) and the FACED score, both of which stratify patients into severity risk categories to predict the probability of mortality. Methods We aimed to compare the predictive utility of BSI and FACED in assessing clinically relevant disease outcomes across seven European cohorts independent of their original validation studies. Results The combined cohorts totalled 1612. Pooled analysis showed that both scores had a good discriminatory predictive value for mortality (pooled area under the curve (AUC) 0.76, 95% CI 0.74 to 0.78 for both scores) with the BSI demonstrating a higher sensitivity (65% vs 28%) but lower specificity (70% vs 93%) compared with the FACED score. Calibration analysis suggested that the BSI performed consistently well across all cohorts, while FACED consistently overestimated mortality in ‘severe’ patients (pooled OR 0.33 (0.23 to 0.48), p<0.0001). The BSI accurately predicted hospitalisations (pooled AUC 0.82, 95% CI 0.78 to 0.84), exacerbations, quality of life (QoL) and respiratory symptoms across all risk categories. FACED had poor discrimination for hospital admissions (pooled AUC 0.65, 95% CI 0.63 to 0.67) with low sensitivity at 16% and did not consistently predict future risk of exacerbations, QoL or respiratory symptoms. No association was observed with FACED and 6 min walk distance (6MWD) or lung function decline. Conclusion The BSI accurately predicts mortality, hospital admissions, exacerbations, QoL, respiratory symptoms, 6MWD and lung function decline in bronchiectasis, providing a clinically relevant evaluation of disease severity. PMID:27516225
Observations of Cold Pool Properties during GoAmazon2014/5
NASA Astrophysics Data System (ADS)
Mayne, S. L.; Schumacher, C.; MacDonald, L.; Turner, D. D.
2017-12-01
Convectively generated cold pools are instrumental in both the development of the sub-cloud layer and the organization of deep convection. Despite this, analyses of cold pools in the tropics are constrained by a lack of observational data; insight into the phenomena therefore relies heavily on numerical models. GoAmazon2014/5, a 2-year DOE-sponsored field campaign centered on Manacapuru, Brazil in the central Amazon, provides a unique opportunity to characterize tropical cold pools and allows for the comparison of observational data with theoretical results from model cold pool simulations and parameterizations. This investigation analyzes radar, disdrometer, and profiler measurements at the DOE mobile facility site to study tropical cold pool characteristics. The Brazilian military (SIPAM) operational S-band radar in Manaus is used to provide a broad context of convective systems, while measurements from Parsivel disdrometers are used to assess drop-size distributions (DSDs) at the surface. A unique aspect of this research is the use of the Atmospheric Emitted Radiance Interferometer (AERI) instrument, which utilizes down-welling IR measurements to obtain vertical profiles of thermodynamic quantities such as temperature and water vapor in the lowest few km of the atmosphere. Combined with surface observations and sounding data, these datasets will result in a thorough investigation of the horizontal and vertical characteristics of cold pools over the tropical rain forest. Preliminary analyses of 20 events reveal a mean cold pool height of 220 m and a mean radius of approximately 8.5 km. The average cold pool experienced a temperature (specific humidity) decrease of approximately 1 K (0.4 g/kg) at the surface. The temperature decrease is consistent with modeling studies and limited observations from previous studies over the tropics. The small decrease in specific humidity is attributed to the high moisture content within the cold pools. AERI retrievals of potential temperature and specific humidity profiles show promising similarities with theoretical results produced using the cold pool parameterization presented by Del Genio et al. (2015); however, results are sensitive to both the mass of air injected into the cold pool after its formation, and the thermodynamic characteristics of the downdraft.
Pathak, Neha; Dodds, Julie; Khan, Khalid
2014-01-01
Objective To determine the accuracy of testing for human papillomavirus (HPV) DNA in urine in detecting cervical HPV in sexually active women. Design Systematic review and meta-analysis. Data sources Searches of electronic databases from inception until December 2013, checks of reference lists, manual searches of recent issues of relevant journals, and contact with experts. Eligibility criteria Test accuracy studies in sexually active women that compared detection of urine HPV DNA with detection of cervical HPV DNA. Data extraction and synthesis Data relating to patient characteristics, study context, risk of bias, and test accuracy. 2×2 tables were constructed and synthesised by bivariate mixed effects meta-analysis. Results 16 articles reporting on 14 studies (1443 women) were eligible for meta-analysis. Most used commercial polymerase chain reaction methods on first void urine samples. Urine detection of any HPV had a pooled sensitivity of 87% (95% confidence interval 78% to 92%) and specificity of 94% (95% confidence interval 82% to 98%). Urine detection of high risk HPV had a pooled sensitivity of 77% (68% to 84%) and specificity of 88% (58% to 97%). Urine detection of HPV 16 and 18 had a pooled sensitivity of 73% (56% to 86%) and specificity of 98% (91% to 100%). Metaregression revealed an increase in sensitivity when urine samples were collected as first void compared with random or midstream (P=0.004). Limitations The major limitations of this review are the lack of a strictly uniform method for the detection of HPV in urine and the variation in accuracy between individual studies. Conclusions Testing urine for HPV seems to have good accuracy for the detection of cervical HPV, and testing first void urine samples is more accurate than random or midstream sampling. When cervical HPV detection is considered difficult in particular subgroups, urine testing should be regarded as an acceptable alternative. PMID:25232064
Woo, Sungmin; Suh, Chong Hyun; Kim, Sang Youn; Cho, Jeong Yeon; Kim, Seung Hyup
2018-01-01
The purpose of this study was to perform a head-to-head comparison between high-b-value (> 1000 s/mm 2 ) and standard-b-value (800-1000 s/mm 2 ) DWI regarding diagnostic performance in the detection of prostate cancer. The MEDLINE and EMBASE databases were searched up to April 1, 2017. The analysis included diagnostic accuracy studies in which high- and standard-b-value DWI were used for prostate cancer detection with histopathologic examination as the reference standard. Methodologic quality was assessed with the revised Quality Assessment of Diagnostic Accuracy Studies tool. Sensitivity and specificity of all studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Meta-regression and multiple-subgroup analyses were performed to compare the diagnostic performances of high- and standard-b-value DWI. Eleven studies (789 patients) were included. High-b-value DWI had greater pooled sensitivity (0.80 [95% CI, 0.70-0.87]) (p = 0.03) and specificity (0.92 [95% CI, 0.87-0.95]) (p = 0.01) than standard-b-value DWI (sensitivity, 0.78 [95% CI, 0.66-0.86]); specificity, 0.87 [95% CI, 0.77-0.93] (p < 0.01). Multiple-subgroup analyses showed that specificity was consistently higher for high- than for standard-b-value DWI (p ≤ 0.05). Sensitivity was significantly higher for high- than for standard-b-value DWI only in the following subgroups: peripheral zone only, transition zone only, multiparametric protocol (DWI and T2-weighted imaging), visual assessment of DW images, and per-lesion analysis (p ≤ 0.04). In a head-to-head comparison, high-b-value DWI had significantly better sensitivity and specificity for detection of prostate cancer than did standard-b-value DWI. Multiple-subgroup analyses showed that specificity was consistently superior for high-b-value DWI.
Sanogo, Yibayiri O; Kim, Chang-Hyun; Lampman, Richard; Novak, Robert J
2007-07-01
In North America, West Nile and St. Louis encephalitis viruses have been detected in a wide range of vector species, but the majority of isolations continue to be from pools of mixed mosquitoes in the Culex subgenus Culex. Unfortunately, the morphologic identification of these important disease vectors is often difficult, particularly in regions of sympatry. We developed a sensitive real-time TaqMan polymerase chain reaction assay that allows reliable identification of Culex mosquitoes including Culex pipiens pipiens, Cx. p. quinquefasciatus, Cx. restuans, Cx. salinarius, Cx. nigripalpus, and Cx. tarsalis. Primers and fluorogenic probes specific to each species were designed based on sequences of the acetylcholinesterase gene (Ace2). Both immature and adult mosquitoes were successfully identified as individuals and as mixed species pools. This identification technique provides the basis for a rapid, sensitive, and high-throughput method for expounding the species-specific contribution of vectors to various phases of arbovirus transmission.
Zur, RM; Roy, LM; Ito, S; Beyene, J; Carew, C; Ungar, WJ
2016-01-01
Thiopurine S-methyltransferase (TPMT) deficiency increases the risk of serious adverse events in persons receiving thiopurines. The objective was to synthesize reported sensitivity and specificity of TPMT phenotyping and genotyping using a latent class hierarchical summary receiver operating characteristic meta-analysis. In 27 studies, pooled sensitivity and specificity of phenotyping for deficient individuals was 75.9% (95% credible interval (CrI), 58.3–87.0%) and 98.9% (96.3–100%), respectively. For genotype tests evaluating TPMT*2 and TPMT*3, sensitivity and specificity was 90.4% (79.1–99.4%) and 100.0% (99.9–100%), respectively. For individuals with deficient or intermediate activity, phenotype sensitivity and specificity was 91.3% (86.4–95.5%) and 92.6% (86.5–96.6%), respectively. For genotype tests evaluating TPMT*2 and TPMT*3, sensitivity and specificity was 88.9% (81.6–97.5%) and 99.2% (98.4–99.9%), respectively. Genotyping has higher sensitivity as long as TPMT*2 and TPMT*3 are tested. Both approaches display high specificity. Latent class meta-analysis is a useful method for synthesizing diagnostic test performance data for clinical practice guidelines. PMID:27217052
Optical coherence tomography for the diagnosis of malignant skin tumors: a meta-analysis
NASA Astrophysics Data System (ADS)
Xiong, Yi-Quan; Mo, Yun; Wen, Yu-Qi; Cheng, Ming-Ji; Huo, Shu-Ting; Chen, Xue-Jiao; Chen, Qing
2018-02-01
Optical coherence tomography (OCT) is an emergent imaging tool used for noninvasive diagnosis of skin diseases. The present meta-analysis was carried out to assess the accuracy of OCT for the diagnosis of skin cancer. We conducted a systematic literature search though EMBASE, Medline, PubMed, the Cochrane Library, and Web of Science database for relevant articles published up to June 6, 2017. The quality of the included studies was assessed using the QUADAS-2 tool and the Oxford Levels of Evidence Scale. Statistical analyses were conducted using the software Meta-Disc version 1.4 and STATA version 12.0. A total of 14 studies involving more than 813 patients with a total of 1958 lesions were included in our analyses. The pooled sensitivity and specificity of OCT for skin cancer diagnoses were 91.8% and 86.7%, respectively. Subgroup analysis showed that the pooled sensitivities of OCT for detecting basal cell carcinoma (BCC), squamous cell carcinoma (SCC), actinic keratosis, and malignant melanoma were 92.4%, 92.3%, 73.8%, and 81.0%, respectively. The pooled specificities were 86.9%, 99.5%, 91.5%, and 93.8%, respectively. OCT appears to be useful for the detection of BCC and SCC. It is a valuable diagnostic method when screening for early skin cancers.
Huang, Yanyan; Khan, Mazhar; Măndoiu, Ion I.
2013-01-01
We have previously developed a software package called PrimerHunter to design primers for PCR-based virus subtyping. In this study, 9 pairs of primers were designed with PrimerHunter and successfully used to differentiate the 9 neuraminidase (NA) genes of avian influenza viruses (AIVs) in multiple PCR-based assays. Furthermore, primer pools were designed and successfully used to decrease the number of reactions needed for NA subtyping from 9 to 4. The quadruplicate primer-pool method is cost-saving, and was shown to be suitable for the NA subtyping of both cultured AIVs and uncultured AIV swab samples. The primers selected for this study showed excellent sensitivity and specificity in NA subtyping by RT-PCR, SYBR green-based Real-time PCR and Real-time RT-PCR methods. AIV RNA of 2 to 200 copies (varied by NA subtypes) could be detected by these reactions. No unspecific amplification was displayed when detecting RNAs of other avian infectious viruses such as Infectious bronchitis virus, Infectious bursal disease virus and Newcastle disease virus. In summary, this study introduced several sensitive and specific PCR-based assays for NA subtyping of AIVs and also validated again the effectiveness of the PrimerHunter tool for the design of subtyping primers. PMID:24312367
Xpert® Mtb/Rif assay for pulmonary tuberculosis and rifampicin resistance in adults
Steingart, Karen R; Schiller, Ian; Horne, David J; Pai, Madhukar; Boehme, Catharina C; Dendukuri, Nandini
2014-01-01
Background Accurate, rapid detection of tuberculosis (TB) and TB drug resistance is critical for improving patient care and decreasing TB transmission. Xpert® MTB/RIF assay is an automated test that can detect both TB and rifampicin resistance, generally within two hours after starting the test, with minimal hands-on technical time. The World Health Organization (WHO) issued initial recommendations on Xpert® MTB/RIF in early 2011. A Cochrane Review on the diagnostic accuracy of Xpert® MTB/RIF for pulmonary TB and rifampicin resistance was published January 2013. We performed this updated Cochrane Review as part of a WHO process to develop updated guidelines on the use of the test. Objectives To assess the diagnostic accuracy of Xpert® MTB/RIF for pulmonary TB (TB detection), where Xpert® MTB/RIF was used as both an initial test replacing microscopy and an add-on test following a negative smear microscopy result. To assess the diagnostic accuracy of Xpert® MTB/RIF for rifampicin resistance detection, where Xpert® MTB/RIF was used as the initial test replacing culture-based drug susceptibility testing (DST). The populations of interest were adults presumed to have pulmonary, rifampicin-resistant or multidrug-resistant TB (MDR-TB), with or without HIV infection. The settings of interest were intermediate- and peripheral-level laboratories. The latter may be associated with primary health care facilities. Search methods We searched for publications in any language up to 7 February 2013 in the following databases: Cochrane Infectious Diseases Group Specialized Register; MEDLINE; EMBASE; ISI Web of Knowledge; MEDION; LILACS; BIOSIS; and SCOPUS. We also searched the metaRegister of Controlled Trials (mRCT) and the search portal of the WHO International Clinical Trials Registry Platform to identify ongoing trials. Selection criteria We included randomized controlled trials, cross-sectional studies, and cohort studies using respiratory specimens that allowed for extraction of data evaluating Xpert® MTB/RIF against the reference standard. We excluded gastric fluid specimens. The reference standard for TB was culture and for rifampicin resistance was phenotypic culture-based DST. Data collection and analysis For each study, two review authors independently extracted data using a standardized form. When possible, we extracted data for subgroups by smear and HIV status. We assessed the quality of studies using QUADAS-2 and carried out meta-analyses to estimate pooled sensitivity and specificity of Xpert® MTB/RIF separately for TB detection and rifampicin resistance detection. For TB detection, we performed the majority of analyses using a bivariate random-effects model and compared the sensitivity of Xpert® MTB/RIF and smear microscopy against culture as reference standard. For rifampicin resistance detection, we undertook univariate meta-analyses for sensitivity and specificity separately to include studies in which no rifampicin resistance was detected. Main results We included 27 unique studies (integrating nine new studies) involving 9557 participants. Sixteen studies (59%) were performed in low- or middle-income countries. For all QUADAS-2 domains, most studies were at low risk of bias and low concern regarding applicability. As an initial test replacing smear microscopy, Xpert® MTB/RIF pooled sensitivity was 89% [95% Credible Interval (CrI) 85% to 92%] and pooled specificity 99% (95% CrI 98% to 99%), (22 studies, 8998 participants: 2953 confirmed TB, 6045 non-TB).As an add-on test following a negative smear microscopy result, Xpert®MTB/RIF pooled sensitivity was 67% (95% CrI 60% to 74%) and pooled specificity 99% (95% CrI 98% to 99%; 21 studies, 6950 participants). For smear-positive, culture-positive TB, Xpert® MTB/RIF pooled sensitivity was 98% (95% CrI 97% to 99%; 21 studies, 1936 participants). For people with HIV infection, Xpert® MTB/RIF pooled sensitivity was 79% (95% CrI 70% to 86%; 7 studies, 1789 participants), and for people without HIV infection, it was 86% (95% CrI 76% to 92%; 7 studies, 1470 participants). Comparison with smear microscopy In comparison with smear microscopy, Xpert® MTB/RIF increased TB detection among culture-confirmed cases by 23% (95% CrI 15% to 32%; 21 studies, 8880 participants). For TB detection, if pooled sensitivity estimates for Xpert® MTB/RIF and smear microscopy are applied to a hypothetical cohort of 1000 patients where 10% of those with symptoms have TB, Xpert® MTB/RIF will diagnose 88 cases and miss 12 cases, whereas sputum microscopy will diagnose 65 cases and miss 35 cases. Rifampicin resistance For rifampicin resistance detection, Xpert® MTB/RIF pooled sensitivity was 95% (95% CrI 90% to 97%; 17 studies, 555 rifampicin resistance positives) and pooled specificity was 98% (95% CrI 97% to 99%; 24 studies, 2411 rifampicin resistance negatives). Among 180 specimens with nontuberculous mycobacteria (NTM), Xpert® MTB/RIF was positive in only one specimen that grew NTM (14 studies, 2626 participants). For rifampicin resistance detection, if the pooled accuracy estimates for Xpert® MTB/RIF are applied to a hypothetical cohort of 1000 individuals where 15% of those with symptoms are rifampicin resistant, Xpert® MTB/RIF would correctly identify 143 individuals as rifampicin resistant and miss eight cases, and correctly identify 833 individuals as rifampicin susceptible and misclassify 17 individuals as resistant. Where 5% of those with symptoms are rifampicin resistant, Xpert® MTB/RIF would correctly identify 48 individuals as rifampicin resistant and miss three cases and correctly identify 931 individuals as rifampicin susceptible and misclassify 19 individuals as resistant. Authors' conclusions In adults thought to have TB, with or without HIV infection, Xpert® MTB/RIF is sensitive and specific. Compared with smear microscopy, Xpert® MTB/RIF substantially increases TB detection among culture-confirmed cases. Xpert® MTB/RIF has higher sensitivity for TB detection in smear-positive than smear-negative patients. Nonetheless, this test may be valuable as an add-on test following smear microscopy in patients previously found to be smear-negative. For rifampicin resistance detection, Xpert® MTB/RIF provides accurate results and can allow rapid initiation of MDR-TB treatment, pending results from conventional culture and DST. The tests are expensive, so current research evaluating the use of Xpert® MTB/RIF in TB programmes in high TB burden settings will help evaluate how this investment may help start treatment promptly and improve outcomes. PMID:24448973
Liu, W; Yin, W; Zhang, R; Li, J; Zheng, Y
2015-06-01
The aim of this study was to evaluate the predictive value of panoramic radiography on inferior alveolar nerve (IAN) injury after extraction of the mandibular third molar. Relevant studies up to 1 June 2014 that discussed the association of panoramic radiography signs and post-mandibular third molar extraction IAN injury were systematically retrieved from the databases of PubMed, Embase, Springerlink, Web of Science and Cochrane library. The effect size of pooled sensitivity, specificity, positive likelihood ratios (PLR), negative likelihood ratios (NLR) and diagnostic odds ratio (DOR) with their 95% confidence intervals (CI) were statistically analysed with Meta-disc 1.4 software. Nine articles were included in this meta-analysis. The pooled estimates of sensitivity and specificity were 0.56 (95% CI: 0.50-0.61) and 0.86 (95% CI: 0.84-0.87), respectively. The overall PLR was 3.46 (95% CI: 2.02-5.92) and overall NLR was 0.58 (95% CI: 0.45-0.73). The pooled estimate of DOR was 6.49 (95% CI: 2.92-14.44). The area under the summary receiver operating characteristic curve was 0.7143 ± 0.0604. The meta-analysis indicated that interpretation of panoramic radiography based on darkening of the root had a high specificity in predicting IAN injury after mandibular third molar extraction. However, the ability of this panoramic radiography marker to detect true positive IAN injury was not satisfactory. © 2015 Australian Dental Association.
Maruotti, G M; Saccone, G; Morlando, M; Martinelli, P
2016-07-01
To evaluate the accuracy of first-trimester sonographic determination of chorionicity in twin gestations using the lambda sign. Electronic databases (MEDLINE, PROSPERO, Scopus, ClinicalTrials.gov, EMBASE, Sciencedirect) were searched from their inception until April 2016. We included only study assessing the accuracy lambda sign in prediction of monochorionicity in the first trimester. Forest plots for pooled sensitivity and specificity with 95% confidence intervals (CI) were generated. In addition, symmetric summary receiver-operating characteristic curves were plotted. The area under the curve (AUC) was also computed to evaluate the overall accuracy of the diagnostic test. Nine studies, including 2292 twins, were analysed. In all of these studies, identification of the lambda sign was used to diagnose chorionicity on real-time B-mode imaging. Twins were classified as monochorionic if there was a single placental mass in the absence of the lambda sign, and dichorionic if there was a single placental mass but the lambda sign was present or the placentas were not adjacent to each other. In all nine studies, placental histology or discordant fetal sex were used to confirm chorionicity. Pooled results from the meta-analysis showed that sensitivity of the presence of the lambda sign in the prediction of dichorionicity was 99% (95% CI 98-100%), and specificity was 95% (95% CI 92-97%). Pooled sensitivity of the absence of the lambda sign in the prediction of monochorionicity was 96% (95% CI 92-98%) and pooled specificity was 99% (95% CI 98-99%). The AUC for diagnostic accuracy was 0.99, and suggested very high diagnostic accuracy. The lambda sign predicts chorionicity with a high degree of accuracy before 14 weeks of gestation. Presence of the lambda sign indicates dichorionicity, and absence of the lambda sign indicates monochorionicity. All hospitals should encourage departments providing ultrasound services to determine chorionicity when examining women with twin pregnancies in the first trimester. As determination of chorionicity is most accurate before 14 weeks when the amnion and chorion have not yet fused, the first-trimester scan in twin pregnancy is paramount. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
McGreavy, Bridie; Webler, Thomas; Calhoun, Aram J K
2012-03-01
In this study, we describe local decision maker attitudes towards vernal pools to inform science communication and enhance vernal pool conservation efforts. We conducted interviews with town planning board and conservation commission members (n = 9) from two towns in the State of Maine in the northeastern United States. We then mailed a questionnaire to a stratified random sample of planning board members in August and September 2007 with a response rate of 48.4% (n = 320). The majority of survey respondents favored the protection and conservation of vernal pools in their towns. Decision makers were familiar with the term "vernal pool" and demonstrated positive attitudes to vernal pools in general. General appreciation and willingness to conserve vernal pools predicted support for the 2006 revisions to the Natural Resource Protection Act regulating Significant Vernal Pools. However, 48% of respondents were unaware of this law and neither prior knowledge of the law nor workshop attendance predicted support for the vernal pool law. Further, concerns about private property rights and development restrictions predicted disagreement with the vernal pool law. We conclude that science communication must rely on specific frames of reference, be sensitive to cultural values, and occur in an iterative system to link knowledge and action in support of vernal pool conservation. Copyright © 2011 Elsevier Ltd. All rights reserved.
Kenyon, Fiona; Rinaldi, Laura; McBean, Dave; Pepe, Paola; Bosco, Antonio; Melville, Lynsey; Devin, Leigh; Mitchell, Gillian; Ianniello, Davide; Charlier, Johannes; Vercruysse, Jozef; Cringoli, Giuseppe; Levecke, Bruno
2016-07-30
In small ruminants, faecal egg counts (FECs) and reduction in FECs (FECR) are the most common methods for the assessment of intensity of gastrointestinal (GI) nematodes infections and anthelmintic drug efficacy, respectively. The main limitation of these methods is the time and cost to conduct FECs on a representative number of individual animals. A cost-saving alternative would be to examine pooled faecal samples, however little is known regarding whether pooling can give representative results. In the present study, we compared the FECR results obtained by both an individual and a pooled examination strategy across different pool sizes and analytical sensitivity of the FEC techniques. A survey was conducted on 5 sheep farms in Scotland, where anthelmintic resistance is known to be widespread. Lambs were treated with fenbendazole (4 groups), levamisole (3 groups), ivermectin (3 groups) or moxidectin (1 group). For each group, individual faecal samples were collected from 20 animals, at baseline (D0) and 14 days after (D14) anthelmintic administration. Faecal samples were analyzed as pools of 3-5, 6-10, and 14-20 individual samples. Both individual and pooled samples were screened for GI strongyle and Nematodirus eggs using two FEC techniques with three different levels of analytical sensitivity, including Mini-FLOTAC (analytical sensitivity of 10 eggs per gram of faeces (EPG)) and McMaster (analytical sensitivity of 15 or 50 EPG).For both Mini-FLOTAC and McMaster (analytical sensitivity of 15 EPG), there was a perfect agreement in classifying the efficacy of the anthelmintic as 'normal', 'doubtful' or 'reduced' regardless of pool size. When using the McMaster method (analytical sensitivity of 50 EPG) anthelmintic efficacy was often falsely classified as 'normal' or assessment was not possible due to zero FECs at D0, and this became more pronounced when the pool size increased. In conclusion, pooling ovine faecal samples holds promise as a cost-saving and efficient strategy for assessing GI nematode FECR. However, for the assessment FECR one will need to consider the baseline FEC, pool size and analytical sensitivity of the method. Copyright © 2016. Published by Elsevier B.V.
Yang, Yan; Gillis, Kevin D
2004-12-01
We have used membrane capacitance measurements and carbon-fiber amperometry to assay exocytosis triggered by photorelease of caged Ca(2+) to directly measure the Ca(2+) sensitivity of exocytosis from the INS-1 insulin-secreting cell line. We find heterogeneity of the Ca(2+) sensitivity of release in that a small proportion of granules makes up a highly Ca(2+)-sensitive pool (HCSP), whereas the bulk of granules have a lower sensitivity to Ca(2+). A substantial HCSP remains after brief membrane depolarization, suggesting that the majority of granules with high sensitivity to Ca(2+) are not located close to Ca(2+) channels. The HCSP is enhanced in size by glucose, cAMP, and a phorbol ester, whereas the Ca(2+)-sensitive rate constant of exocytosis from the HCSP is unaffected by cAMP and phorbol ester. The effects of cAMP and phorbol ester on the HCSP are mediated by PKA and PKC, respectively, because they can be blocked with specific protein kinase inhibitors. The size of the HCSP can be enhanced by glucose even in the presence of high concentrations of phorbol ester or cAMP, suggesting that glucose can increase granule pool sizes independently of activation of PKA or PKC. The effects of PKA and PKC on the size of the HCSP are not additive, suggesting they converge on a common mechanism. Carbon-fiber amperometry was used to assay quantal exocytosis of serotonin (5-HT) from insulin-containing granules following preincubation of INS-1 cells with 5-HT and a precursor. The amount or kinetics of release of 5-HT from each granule is not significantly different between granules with higher or lower sensitivity to Ca(2+), suggesting that granules in these two pools do not differ in morphology or fusion kinetics. We conclude that glucose and second messengers can modulate insulin release triggered by a high-affinity Ca(2+) sensor that is poised to respond to modest, global elevations of [Ca(2+)](i).
Taylor-Phillips, Sian; Freeman, Karoline; Geppert, Julia; Agbebiyi, Adeola; Uthman, Olalekan A; Madan, Jason; Clarke, Angus; Quenby, Siobhan; Clarke, Aileen
2016-01-01
Objective To measure test accuracy of non-invasive prenatal testing (NIPT) for Down, Edwards and Patau syndromes using cell-free fetal DNA and identify factors affecting accuracy. Design Systematic review and meta-analysis of published studies. Data sources PubMed, Ovid Medline, Ovid Embase and the Cochrane Library published from 1997 to 9 February 2015, followed by weekly autoalerts until 1 April 2015. Eligibility criteria for selecting studies English language journal articles describing case–control studies with ≥15 trisomy cases or cohort studies with ≥50 pregnant women who had been given NIPT and a reference standard. Results 41, 37 and 30 studies of 2012 publications retrieved were included in the review for Down, Edwards and Patau syndromes. Quality appraisal identified high risk of bias in included studies, funnel plots showed evidence of publication bias. Pooled sensitivity was 99.3% (95% CI 98.9% to 99.6%) for Down, 97.4% (95.8% to 98.4%) for Edwards, and 97.4% (86.1% to 99.6%) for Patau syndrome. The pooled specificity was 99.9% (99.9% to 100%) for all three trisomies. In 100 000 pregnancies in the general obstetric population we would expect 417, 89 and 40 cases of Downs, Edwards and Patau syndromes to be detected by NIPT, with 94, 154 and 42 false positive results. Sensitivity was lower in twin than singleton pregnancies, reduced by 9% for Down, 28% for Edwards and 22% for Patau syndrome. Pooled sensitivity was also lower in the first trimester of pregnancy, in studies in the general obstetric population, and in cohort studies with consecutive enrolment. Conclusions NIPT using cell-free fetal DNA has very high sensitivity and specificity for Down syndrome, with slightly lower sensitivity for Edwards and Patau syndrome. However, it is not 100% accurate and should not be used as a final diagnosis for positive cases. Trial registration number CRD42014014947. PMID:26781507
Yu, Channing; Mannan, Aristotle M.; Yvone, Griselda Metta; Ross, Kenneth N.; Zhang, Yan-Ling; Marton, Melissa A.; Taylor, Bradley R.; Crenshaw, Andrew; Gould, Joshua Z.; Tamayo, Pablo; Weir, Barbara A.; Tsherniak, Aviad; Wong, Bang; Garraway, Levi A.; Shamji, Alykhan F.; Palmer, Michelle A.; Foley, Michael A.; Winckler, Wendy; Schreiber, Stuart L.; Kung, Andrew L.; Golub, Todd R.
2016-01-01
Hundreds of genetically characterized cell lines are available for the discovery of genotype-specific cancer vulnerabilities. However, screening large numbers of compounds against large numbers of cell lines is currently impractical, and such experiments are often difficult to control1-4. Here, we report a method called PRISM that allows pooled screening of mixtures of cancer cell lines by labeling each cell line with 24-nucleotide barcodes. PRISM displayed the expected patterns of cell killing seen in conventional (unpooled) assays. In a screen of 102 cell lines across 8,400 compounds, PRISM led to the identification of BRD-7880 as a potent and highly specific inhibitor of aurora kinases B and C. Cell line pools also efficiently formed tumors as xenografts, and PRISM recapitulated the expected pattern of erlotinib sensitivity in vivo. PMID:26928769
Wang, Shui-Hua; Phillips, Preetha; Sui, Yuxiu; Liu, Bin; Yang, Ming; Cheng, Hong
2018-03-26
Alzheimer's disease (AD) is a progressive brain disease. The goal of this study is to provide a new computer-vision based technique to detect it in an efficient way. The brain-imaging data of 98 AD patients and 98 healthy controls was collected using data augmentation method. Then, convolutional neural network (CNN) was used, CNN is the most successful tool in deep learning. An 8-layer CNN was created with optimal structure obtained by experiences. Three activation functions (AFs): sigmoid, rectified linear unit (ReLU), and leaky ReLU. The three pooling-functions were also tested: average pooling, max pooling, and stochastic pooling. The numerical experiments demonstrated that leaky ReLU and max pooling gave the greatest result in terms of performance. It achieved a sensitivity of 97.96%, a specificity of 97.35%, and an accuracy of 97.65%, respectively. In addition, the proposed approach was compared with eight state-of-the-art approaches. The method increased the classification accuracy by approximately 5% compared to state-of-the-art methods.
2015-01-01
Summary Background Diabetes has been defined on the basis of different biomarkers, including fasting plasma glucose (FPG), 2-h plasma glucose in an oral glucose tolerance test (2hOGTT), and HbA1c. We assessed the effect of different diagnostic definitions on both the population prevalence of diabetes and the classification of previously undiagnosed individuals as having diabetes versus not having diabetes in a pooled analysis of data from population-based health examination surveys in different regions. Methods We used data from 96 population-based health examination surveys that had measured at least two of the biomarkers used for defining diabetes. Diabetes was defined using HbA1c (HbA1c ≥6·5% or history of diabetes diagnosis or using insulin or oral hypoglycaemic drugs) compared with either FPG only or FPG-or-2hOGTT definitions (FPG ≥7·0 mmol/L or 2hOGTT ≥11·1 mmol/L or history of diabetes or using insulin or oral hypoglycaemic drugs). We calculated diabetes prevalence, taking into account complex survey design and survey sample weights. We compared the prevalences of diabetes using different definitions graphically and by regression analyses. We calculated sensitivity and specificity of diabetes diagnosis based on HbA1c compared with diagnosis based on glucose among previously undiagnosed individuals (ie, excluding those with history of diabetes or using insulin or oral hypoglycaemic drugs). We calculated sensitivity and specificity in each survey, and then pooled results using a random-effects model. We assessed the sources of heterogeneity of sensitivity by meta-regressions for study characteristics selected a priori. Findings Population prevalence of diabetes based on FPG-or-2hOGTT was correlated with prevalence based on FPG alone (r=0·98), but was higher by 2–6 percentage points at different prevalence levels. Prevalence based on HbA1c was lower than prevalence based on FPG in 42·8% of age–sex–survey groups and higher in another 41·6%; in the other 15·6%, the two definitions provided similar prevalence estimates. The variation across studies in the relation between glucose-based and HbA1c-based prevalences was partly related to participants' age, followed by natural logarithm of per person gross domestic product, the year of survey, mean BMI, and whether the survey population was national, subnational, or from specific communities. Diabetes defined as HbA1c 6·5% or more had a pooled sensitivity of 52·8% (95% CI 51·3–54·3%) and a pooled specificity of 99·74% (99·71–99·78%) compared with FPG 7·0 mmol/L or more for diagnosing previously undiagnosed participants; sensitivity compared with diabetes defined based on FPG-or-2hOGTT was 30·5% (28·7–32·3%). None of the preselected study-level characteristics explained the heterogeneity in the sensitivity of HbA1c versus FPG. Interpretation Different biomarkers and definitions for diabetes can provide different estimates of population prevalence of diabetes, and differentially identify people without previous diagnosis as having diabetes. Using an HbA1c-based definition alone in health surveys will not identify a substantial proportion of previously undiagnosed people who would be considered as having diabetes using a glucose-based test. Funding Wellcome Trust, US National Institutes of Health. PMID:26109024
Wang, Sen; Chen, Jiazhen; Zhang, Ying; Diao, Ni; Zhang, Shu; Wu, Jing; Lu, Chanyi; Wang, Feifei; Gao, Yan; Shao, Lingyun; Jin, Jialin; Weng, Xinhua; Zhang, Wenhong
2013-01-01
Antigens encoded in the region of difference (RD) of Mycobacterium tuberculosis constitute a potential source of specific immunodiagnostic antigens for distinguishing tuberculosis (TB) infection from BCG vaccination. We evaluated the diagnostic potential of specific T-cell epitopes selected from two immunodominant antigens, Rv1985c and Rv3425, from RD2 and RD11, respectively, on the basis of epitope mapping, in TB patients and BCG-vaccinated healthy individuals. Using a whole-blood gamma interferon release assay, a wide array of epitopes was recognized on both Rv1985c and Rv3425 in TB patients. Those epitopes that could specifically discriminate TB infection from BCG vaccination were carefully selected, and the most promising peptide pools from Rv1985c showed a sensitivity of 53.9% and a specificity of 95.5%. When the novel specific peptides from Rv1985c joined the diagnostic antigens in the QuantiFERON-TB Gold In-Tube (QFT-IT) assay, the sensitivity was increased from 86.4% to 96.2%, with no drop in specificity. These results indicate that the peptide pools selected from Rv1985c and Rv3425 have the potential to diagnose TB infection by a method that may be routinely used in clinical laboratories.
Daamen, Lois A; Groot, Vincent P; Heerkens, Hanne D; Intven, Martijn P W; van Santvoort, Hjalmar C; Molenaar, I Quintus
2018-04-01
Biomarker testing can be helpful to monitor disease progression after resection of pancreatic cancer. This systematic review aims to give an overview of the literature on the diagnostic value of serum tumor markers for the detection of recurrent pancreatic cancer during follow-up. A systematic search was performed to 2 October 2017. All studies reporting on the diagnostic value of postoperatively measured serum biomarkers for the detection of pancreatic cancer recurrence were included. Data on diagnostic accuracy of tumor markers were extracted. Forest plots and pooled values of sensitivity and specificity were calculated. Four articles described test results of CA 19-9. A pooled sensitivity and specificity of respectively 0.73 (95% CI 0.66-0.80) and 0.83 (95% CI 0.73-0.91) were calculated. One article reported on CEA, showing a sensitivity of 50% and specificity of 65%. No other serum tumor markers were discussed for surveillance purposes in the current literature. Although testing of serum CA 19-9 has considerable limitations, CA 19-9 remains the most used serum tumor marker for surveillance after surgical resection of pancreatic cancer. Further studies are needed to assess the role of serum tumor marker testing in the detection of recurrent pancreatic cancer and to optimize surveillance strategies. Copyright © 2017 International Hepato-Pancreato-Biliary Association Inc. Published by Elsevier Ltd. All rights reserved.
Tseng, Dorine S J; van Santvoort, Hjalmar C; Fegrachi, Samira; Besselink, Marc G; Zuithoff, Nicolaas P A; Borel Rinkes, Inne H; van Leeuwen, Maarten S; Molenaar, I Quintus
2014-12-01
Computed tomography (CT) is the most widely used method to assess resectability of pancreatic and peri-ampullary cancer. One of the contra-indications for curative resection is the presence of extra-regional lymph node metastases. This meta-analysis investigates the accuracy of CT in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. We systematically reviewed the literature according to the PRISMA guidelines. Studies reporting on CT assessment of extra-regional lymph nodes in patients undergoing pancreatoduodenectomy were included. Data on baseline characteristics, CT-investigations and histopathological outcomes were extracted. Diagnostic accuracy, positive predictive value (PPV), negative predictive value (NPV), sensitivity and specificity were calculated for individual studies and pooled data. After screening, 4 cohort studies reporting on CT-findings and histopathological outcome in 157 patients with pancreatic or peri-ampullary cancer were included. Overall, diagnostic accuracy, specificity and NPV varied from 63 to 81, 80-100% and 67-90% respectively. However, PPV and sensitivity ranged from 0 to 100% and 0-38%. Pooled sensitivity, specificity, PPV and NPV were 25%, 86%, 28% and 84% respectively. CT has a low diagnostic accuracy in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. Therefore, suspicion of extra-regional lymph node metastases on CT alone should not be considered a contra-indication for exploration. Copyright © 2014 Elsevier Ltd. All rights reserved.
Xu, Mei-Mei; Jia, Hong-Yu; Yan, Li-Li; Li, Shan-Shan; Zheng, Yue
2017-01-01
Abstract Background: This meta-analysis aimed to provide a pooled analysis of prospective controlled trials comparing the diagnostic accuracy of 22-G and 25-G needles on endoscopic ultrasonography (EUS-FNA) of the solid pancreatic mass. Methods: We established a rigorous study protocol according to Cochrane Collaboration recommendations. We systematically searched the PubMed and Embase databases to identify articles to include in the meta-analysis. Sensitivity, specificity, and corresponding 95% confidence intervals were calculated for 22-G and 25-G needles of individual studies from the contingency tables. Results: Eleven prospective controlled trials included a total of 837 patients (412 with 22-G vs 425 with 25-G). Our outcomes revealed that 25-G needles (92% [95% CI, 89%–95%]) have higher sensitivity than 22-G needles (88% [95% CI, 84%–91%]) on solid pancreatic mass EUS-FNA (P = 0.046). However, there were no significant differences between the 2 groups in overall diagnostic specificity (P = 0.842). The pooled positive and negative likelihood ratio of the 22-G needle were 12.61 (95% CI, 5.65–28.14) and 0.16 (95% CI, 0.12–0.21), respectively. The pooled positive likelihood ratio was 12.61 (95% CI, 5.65–28.14), and the negative likelihood ratio was 0.16 (95% CI, 0.12–0.21) for the 22-G needle. The pooled positive likelihood ratio was 8.44 (95% CI, 3.87–18.42), and the negative likelihood ratio was 0.13 (95% CI, 0.09–0.18) for the 25-G needle. The area under the summary receiver operating characteristic curve was 0.97 for the 22-G needle and 0.96 for the 25-G needle. Conclusion: Compared to the study of 22-G EUS-FNA needles, our study showed that 25-G needles have superior sensitivity in the evaluation of solid pancreatic lesions by EUS–FNA. PMID:28151856
Estimating sensitivity and specificity for technology assessment based on observer studies.
Nishikawa, Robert M; Pesce, Lorenzo L
2013-07-01
The goal of this study was to determine the accuracy and precision of using scores from a receiver operating characteristic rating scale to estimate sensitivity and specificity. We used data collected in a previous study that measured the improvements in radiologists' ability to classify mammographic microcalcification clusters as benign or malignant with and without the use of a computer-aided diagnosis scheme. Sensitivity and specificity were estimated from the rating data from a question that directly asked the radiologists their biopsy recommendations, which was used as the "truth," because it is the actual recall decision, thus it is their subjective truth. By thresholding the rating data, sensitivity and specificity were estimated for different threshold values. Because of interreader and intrareader variability, estimated sensitivity and specificity values for individual readers could be as much as 100% in error when using rating data compared to using the biopsy recommendation data. When pooled together, the estimates using thresholding the rating data were in good agreement with sensitivity and specificity estimated from the recommendation data. However, the statistical power of the rating data estimates was lower. By simply asking the observer his or her explicit recommendation (eg, biopsy or no biopsy), sensitivity and specificity can be measured directly, giving a more accurate description of empirical variability and the power of the study can be maximized. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.
Wang, X W; Pappoe, F; Huang, Y; Cheng, X W; Xu, D F; Wang, H; Xu, Y H
2015-01-01
The Xpert MTB/RIF assay has been recommended by WHO to replace conventional microscopy, culture, and drug resistance tests. It simultaneously detects both Mycobacterium tuberculosis infection (TB) and resistance to rifampicin (RIF) within two hours. The objective was to review the available research studies on the accuracy of the Xpert MTB/RIF assay for diagnosing pulmonary TB and RIF-resistance in children. A comprehensive search of Pubmed and Embase was performed up to October 28, 2014. We identified published articles estimating the diagnostic accuracy of the Xpert MTB/RIF assay in children with or without HIV using culture or culture plus clinical TB as standard reference. QUADAS-2 tool was used to evaluate the quality of the studies. A summary estimation for sensitivity, specificity, diagnostic odds ratios (DOR), and the area under the summary ROC curve (AUC) was performed. Meta-analysis was used to establish the overall accuracy. 11 diagnostic studies with 3801 patients were included in the systematic review. The overall analysis revealed a moderate sensitivity and high specificity of 65% (95% CI: 61 - 69%) and 99% (95% CI: 98 - 99%), respectively, and a pooled diagnostic odds ratio of 164.09 (95% CI: 111.89 - 240.64). The AUC value was found to be 0.94. The pooled sensitivity and specificity for paediatric rifampicin resistance were 94.0% (95% CI: 80.0 - 93.0%) and 99.0% (95% CI: 95.0 - 98.0%), respectively. Hence, the Xpert MTB/RIF assay has good diagnostic and rifampicin performance for paediatric pulmonary tuberculosis. The Xpert MTB/RIF is sensitive and specific for diagnosing paediatric pulmonary TB. It is also effective in detecting rifamnicin resistance. It can, therefore, be used as an initial diagnostic tool.
Liu, Bo-Ji; Li, Dan-Dan; Xu, Hui-Xiong; Guo, Le-Hang; Zhang, Yi-Feng; Xu, Jun-Mei; Liu, Chang; Liu, Lin-Na; Li, Xiao-Long; Xu, Xiao-Hong; Qu, Shen; Xing, Mingzhao
2015-12-01
The aim of this study was to evaluate the diagnostic performance of quantitative shear wave velocity (SWV) measurement on acoustic radiation force impulse (ARFI) elastography for differentiation between benign and malignant thyroid nodules using meta-analysis. The databases of PubMed and the Web of Science were searched. Studies published in English on assessment of the sensitivity and specificity of ARFI elastography for the differentiation of thyroid nodules were collected. The quantitative measurement of ARFI elastography was evaluated by SWV (m/s). Meta-Disc Version 1.4 software was used to describe and calculate the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and summary receiver operating characteristic curves. We analyzed a total of 13 studies, which included 1,854 thyroid nodules (including 1,339 benign nodules and 515 malignant nodules) from 1,641 patients. The summary sensitivity and specificity for differential diagnosis between benign and malignant thyroid nodules by SWV were 0.81 (95% confidence interval [CI]: 0.77-0.84) and 0.84 (95% CI: 0.81-0.86), respectively. The pooled positive and negative likelihood ratios were 5.21 (95% CI: 3.56-7.62) and 0.23 (95% CI: 0.17-0.32), respectively. The pooled diagnostic odds ratio was 27.53 (95% CI: 14.58-52.01), and the area under the summary receiver operating characteristic curve was 0.91 (Q* = 0.84). In conclusion, SWV measurement on ARFI elastography has high sensitivity and specificity for differential diagnosis between benign and malignant thyroid nodules and can be used in combination with conventional ultrasound. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Smith, Toby O; Simpson, Michael; Ejindu, Vivian; Hing, Caroline B
2013-04-01
The purpose of this study was to assess the diagnostic test accuracy of magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and multidetector arrays in CT arthrography (MDCT) for assessing chondral lesions in the hip joint. A review of the published and unpublished literature databases was performed to identify all studies reporting the diagnostic test accuracy (sensitivity/specificity) of MRI, MRA or MDCT for the assessment of adults with chondral (cartilage) lesions of the hip with surgical comparison (arthroscopic or open) as the reference test. All included studies were reviewed using the quality assessment of diagnostic accuracy studies appraisal tool. Pooled sensitivity, specificity, likelihood ratios and diagnostic odds ratios were calculated with 95 % confidence intervals using a random-effects meta-analysis for MRI, MRA and MDCT imaging. Eighteen studies satisfied the eligibility criteria. These included 648 hips from 637 patients. MRI indicated a pooled sensitivity of 0.59 (95 % CI: 0.49-0.70) and specificity of 0.94 (95 % CI: 0.90-0.97), and MRA sensitivity and specificity values were 0.62 (95 % CI: 0.57-0.66) and 0.86 (95 % CI: 0.83-0.89), respectively. The diagnostic test accuracy for the detection of hip joint cartilage lesions is currently superior for MRI compared with MRA. There were insufficient data to perform meta-analysis for MDCT or CTA protocols. Based on the current limited diagnostic test accuracy of the use of magnetic resonance or CT, arthroscopy remains the most accurate method of assessing chondral lesions in the hip joint.
Liu, Ting; He, Xiang-ge
2006-05-01
To evaluate the overall diagnostic capabilities of frequency-doubling technology (FDT) in patients of primary glaucoma, with standard automated perimetry (SAP) and/or optic disc appearance as the gold standard. A comprehensive electric search in MEDLINE, EMBASE, Cochrane Library, BIOSIS, Previews, HMIC, IPA, OVID, CNKI, CBMdisc, VIP information, CMCC, CCPD, SSreader and 21dmedia and a manual search in related textbooks, journals, congress articles and their references were performed to identify relevant English and Chinese language articles. Criteria for adaptability were established according to validity criteria for diagnostic research published by the Cochrane Methods Group on Screening and Diagnostic Tests. Quality of the included articles was assessed and relevant materials were extracted for studying. Statistical analysis was performed with Meta Test version 0.6 software. Heterogeneity of the included articles was tested, which was used to select appropriate effect model to calculate pooled weighted sensitivity and specificity. Summary Receiver Operating Characteristic (SROC) curve was established and the area under the curve (AUC) was calculated. Finally, sensitivity analysis was performed. Fifteen English articles (21 studies) of 206 retrieved articles were included in the present study, with a total of 3172 patients. The reported sensitivity of FDT ranged from 0.51 to 1.00, and specificity from 0.58 to 1.00. The pooled weighted sensitivity and specificity for FDT with 95% confidence intervals (95% CI) after correction for standard error were 0.86 (0.80 - 0.90), 0.87 (0.81 - 0.91), respectively. The AUC of SROC was 93.01%. Sensitivity analysis demonstrated no disproportionate influences of individual study. The included articles are of good quality and FDT can be a highly efficient diagnostic test for primary glaucoma based on Meta-analysis. However, a high quality perspective study is still required for further analysis.
Smith, Melvyn Howard; Hodgson, Julian; Eltringham, Ian Joseph
2010-12-01
As health services move toward universal methicillin-resistant Staphylococcus aureus (MRSA) screening for hospital admissions, the most cost-effective approach is yet to be defined. In this study, one of the largest to date, we evaluated the performance of the BD GeneOhm MRSA assay on the Rotor-Gene 6000 thermal cycler, using samples taken directly from pooled MRSA screens. Results were compared with the same assay performed on the Smart-Cycler II platform and overnight broth culture. Samples yielding discrepant results were subjected to detailed analysis with an in-house PCR and patient note review. A total of 1,428 pooled MRSA screens were tested. Sensitivities and specificities of 85.3% and 95.8% for the Rotor-Gene and 81% and 95.7% for the Smart-Cycler were obtained, compared with broth enrichment. The sensitivity of the BD GeneOhm assay was increased to 100% when the results of in-house PCR and patient note review were taken into account. This study demonstrates that the Rotor-Gene 6000 thermal cycler is a reliable platform for use with the BD GeneOhm assay. It also proves that commercial PCR can be performed direct on pooled samples in selective broth, without the need for overnight incubation.
Bao, Yixia; Chen, Zhimin; Liu, Enmei; Xiang, Li; Zhao, Deyu; Hong, Jianguo
2017-11-18
The aim of this study was to identify risk factors of asthma among children < 6 years old (preschool age) for predicting asthma during the preschool age and early school age (≤ 10 years of age). MEDLINE, Cochrane, EMBASE, and Google Scholar databases were searched until June 30, 2017. Prospective or retrospective cohort and case-control studies were included. Studies had to have evaluated risk factors or a predictive model for developing asthma in children ≤ 6 years of age or persistent asthma in early school age. A total of 17 studies were included in the analysis. Factors associated with developing asthma in children ≤ 10 years of age (both pre-school and early school age) included male gender (pooled OR = 1.70, P < 0.001), atopic dermatitis (pooled OR = 2.02, P < 0.001), a family history of asthma (pooled OR = 2.20, P < 0.001), and serum IgE levels ≥ 60 kU/l or having specific IgE (pooled OR = 2.36, P < 0.001). A history of exposure to smoke or wheezing was also associated with persistent asthma in early school age (pooled OR = 1.51, P = 0.030 and pooled OR = 2.59, P < 0.001, respectively). In general, asthma predictive models (e.g., API, PIAMA, PAPS) had relatively low sensitivity (range, 21% to 71.4%) but high specificity (range, 69% to 98%). The study found that male gender, exposure to smoke, atopic dermatitis, family history of asthma, history of wheezing, and serum IgE level ≥ 60 kU/l or having specific IgE were significantly associated with developing asthma by either preschool or early school age. Asthma predictive models can be developed by those risk factors.
Wang, Jingwen; Skoog, Tiina; Einarsdottir, Elisabet; Kaartokallio, Tea; Laivuori, Hannele; Grauers, Anna; Gerdhem, Paul; Hytönen, Marjo; Lohi, Hannes; Kere, Juha; Jiao, Hong
2016-01-01
High-throughput sequencing using pooled DNA samples can facilitate genome-wide studies on rare and low-frequency variants in a large population. Some major questions concerning the pooling sequencing strategy are whether rare and low-frequency variants can be detected reliably, and whether estimated minor allele frequencies (MAFs) can represent the actual values obtained from individually genotyped samples. In this study, we evaluated MAF estimates using three variant detection tools with two sets of pooled whole exome sequencing (WES) and one set of pooled whole genome sequencing (WGS) data. Both GATK and Freebayes displayed high sensitivity, specificity and accuracy when detecting rare or low-frequency variants. For the WGS study, 56% of the low-frequency variants in Illumina array have identical MAFs and 26% have one allele difference between sequencing and individual genotyping data. The MAF estimates from WGS correlated well (r = 0.94) with those from Illumina arrays. The MAFs from the pooled WES data also showed high concordance (r = 0.88) with those from the individual genotyping data. In conclusion, the MAFs estimated from pooled DNA sequencing data reflect the MAFs in individually genotyped samples well. The pooling strategy can thus be a rapid and cost-effective approach for the initial screening in large-scale association studies. PMID:27633116
Systematic review and meta-analysis of flow cytometry in urinary tract infection screening.
Shang, Yan-Jun; Wang, Qian-Qian; Zhang, Jian-Rong; Xu, Yu-Lian; Zhang, Wei-Wei; Chen, Yan; Gu, Ming-Li; Hu, Zhi-De; Deng, An-Mei
2013-09-23
Automated urine sediment analysis of white blood cells (WBCs) and bacteria is a promising approach for urinary tract infections (UTIs) screening. However, available data on their screening efficacy is inconsistent. English articles from Pubmed, EMBASE, and Web of Science published before December 1, 2012 were analyzed. The Quality Assessment for Studies of Diagnostic Accuracy (QUADAS) tool was used to evaluate the quality of eligible studies. Performance characteristics of WBCs and bacteria (sensitivity, specificity, and other measures of accuracy) were pooled and examined by random-effects models. Nineteen studies containing 22,305 samples were included. Pooled sensitivities were 0.87 (95% confidence interval [CI], 0.86-0.89) for WBCs and 0.92 (95% CI, 0.91-0.93) for bacteria. Corresponding pooled specificities were 0.67 (95% CI, 0.66-0.68) for WBCs and 0.60 (95% CI, 0.59-0.61) for bacteria. Areas under the summary receiver operating characteristics curves were 0.87 and 0.93 for WBCs and bacteria, respectively. The major limitation of eligible studies was that enrolled subjects were often not representative of clinical patient populations in which UTI would be suspected. WBC and bacterial measurements by the UF-100 and UF-1000i are useful indicators in UTI screening; however, the performances of these systems should be rigorously evaluated by additional studies. Copyright © 2013 Elsevier B.V. All rights reserved.
Frosth, Sara; König, Ulrika; Nyman, Ann-Kristin; Aspán, Anna
2017-09-01
Dichelobacter nodosus is the principal cause of ovine footrot and strain virulence is an important factor in disease severity. Therefore, detection and virulence determination of D. nodosus is important for proper diagnosis of the disease. Today this is possible by real-time PCR analysis. Analysis of large numbers of samples is costly and laborious; therefore, pooling of individual samples is common in surveillance programs. However, pooling can reduce the sensitivity of the method. The aim of this study was to develop a pooling method for real-time PCR analysis that would allow sensitive detection and simultaneous virulence determination of D. nodosus. A total of 225 sheep from 17 flocks were sampled using ESwabs within the Swedish Footrot Control Program in 2014. Samples were first analysed individually and then in pools of five by real-time PCR assays targeting the 16S rRNA and aprV2/B2 genes of D. nodosus. Each pool consisted of four negative and one positive D. nodosus samples with varying amounts of the bacterium. In the individual analysis, 61 (27.1%) samples were positive in the 16S rRNA and the aprV2/B2 PCR assays and 164 (72.9%) samples were negative. All samples positive in the aprV2/B2 PCR-assay were of aprB2 variant. The pooled analysis showed that all 41 pools were also positive for D. nodosus 16S rRNA and the aprB2 variant. The diagnostic sensitivity for pooled and individual samples was therefore similar. Our method includes concentration of the bacteria before DNA-extraction. This may account for the maintenance of diagnostic sensitivity. Diagnostic sensitivity in the real-time PCR assays of the pooled samples were comparable to the sensitivity obtained for individually analysed samples. Even sub-clinical infections were able to be detected in the pooled PCR samples which is important for control of the disease. This method may therefore be implemented in footrot control programs where it can replace analysis of individual samples.
Diagnostic Accuracy of Rating Scales for Attention-Deficit/Hyperactivity Disorder: A Meta-analysis.
Chang, Ling-Yin; Wang, Mei-Yeh; Tsai, Pei-Shan
2016-03-01
The Child Behavior Checklist-Attention Problem (CBCL-AP) scale and Conners Rating Scale-Revised (CRS-R) are commonly used behavioral rating scales for diagnosing attention-deficit/hyperactivity disorder (ADHD) in children and adolescents. To evaluate and compare the diagnostic performance of CBCL-AP and CRS-R in diagnosing ADHD in children and adolescents. PubMed, Ovid Medline, and other relevant electronic databases were searched for articles published up to May 2015. We included studies evaluating the diagnostic performance of either CBCL-AP scale or CRS-R for diagnosing ADHD in pediatric populations in comparison with a defined reference standard. Bivariate random effects models were used for pooling and comparing diagnostic performance. We identified and evaluated 14 and 11 articles on CBCL-AP and CRS-R, respectively. The results revealed pooled sensitivities of 0.77, 0.75, 0.72, and 0.83 and pooled specificities of 0.73, 0.75, 0.84, and 0.84 for CBCL-AP, Conners Parent Rating Scale-Revised, Conners Teacher Rating Scale-Revised, and Conners Abbreviated Symptom Questionnaire (ASQ), respectively. No difference was observed in the diagnostic performance of the various scales. Study location, age of participants, and percentage of female participants explained the heterogeneity in the specificity of the CBCL-AP. CBCL-AP and CRS-R both yielded moderate sensitivity and specificity in diagnosing ADHD. According to the comparable diagnostic performance of all examined scales, ASQ may be the most effective diagnostic tool in assessing ADHD because of its brevity and high diagnostic accuracy. CBCL is recommended for more comprehensive assessments. Copyright © 2016 by the American Academy of Pediatrics.
[Reliability and validity of depression scales of Chinese version: a systematic review].
Sun, X Y; Li, Y X; Yu, C Q; Li, L M
2017-01-10
Objective: Through systematically reviewing the reliability and validity of depression scales of Chinese version in adults in China to evaluate the psychometric properties of depression scales for different groups. Methods: Eligible studies published before 6 May 2016 were retrieved from the following database: CNKI, Wanfang, PubMed and Embase. The HSROC model of the diagnostic test accuracy (DTA) for Meta-analysis was used to calculate the pooled sensitivity and specificity of the PHQ-9. Results: A total of 44 papers evaluating the performance of depression scales were included. Results showed that the reliability and validity of the common depression scales were eligible, including the Beck depression inventory (BDI), the Hamilton depression scale (HAMD), the center epidemiological studies depression scale (CES-D), the patient health questionnaire (PHQ) and the Geriatric depression scale (GDS). The Cronbach' s coefficient of most tools were larger than 0.8, while the test-retest reliability and split-half reliability were larger than 0.7, indicating good internal consistency and stability. The criterion validity, convergent validity, discrimination validity and screening validity were acceptable though different cut-off points were recommended by different studies. The pooled sensitivity of the 11 studies evaluating PHQ-9 was 0.88 (95 %CI : 0.85-0.91) while the pooled specificity was 0.89 (95 %CI : 0.82-0.94), which demonstrated the applicability of PHQ-9 in screening depression. Conclusion: The reliability and validity of different depression scales of Chinese version are acceptable. The characteristics of different tools and study population should be taken into consideration when choosing a specific scale.
Martin, Jaclyn; Carrillo, Yisel; Talley, Justin L.; Ochoa-Corona, Francisco M.
2018-01-01
Background The importance of tick and flea-borne rickettsia infections is increasingly recognized worldwide. While increased focus has shifted in recent years to the development of point-of-care diagnostics for various vector-borne diseases in humans and animals, little research effort has been devoted to their integration into vector surveillance and control programs, particularly in resource-challenged countries. One technology which may be helpful for large scale vector surveillance initiatives is loop-mediated isothermal amplification (LAMP). The aim of this study was to develop a LAMP assay to detect spotted fever group (SFG) rickettsia DNA from field-collected ticks and fleas and compare with published end-point PCR results. Methodology/Principal findings A Spotted Fever Group rickettsia-specific loop-mediated isothermal amplification (SFGR-LAMP) assay was developed using primers based on a region of the R. rickettsii 17kDa protein gene. The sensitivity, specificity, and reproducibility of the assay were evaluated. The assay was then compared with the results of end-point PCR assays for pooled tick and flea samples obtained from field-based surveillance studies. The sensitivity of the SFGR-LAMP assay was 0.00001 ng/μl (25μl volume) which was 10 times more sensitive than the 17kDa protein gene end-point PCR used as the reference method. The assay only recognized gDNA from SFG and transitional group (TRG) rickettsia species tested but did not detect gDNA from typhus group (TG) rickettsia species or closely or distantly related bacterial species. The SFGR-LAMP assay detected the same positives from a set of pooled tick and flea samples detected by end-point PCR in addition to two pooled flea samples not detected by end-point PCR. Conclusions/significance To our knowledge, this is the first study to develop a functional LAMP assay to initially screen for SFG and TRG rickettsia pathogens in field-collected ticks and fleas. With a high sensitivity and specificity, the results indicate the potential use as a field-based surveillance tool for tick and flea-borne rickettsial pathogens in resource-challenged countries. PMID:29390021
Noden, Bruce H; Martin, Jaclyn; Carrillo, Yisel; Talley, Justin L; Ochoa-Corona, Francisco M
2018-01-01
The importance of tick and flea-borne rickettsia infections is increasingly recognized worldwide. While increased focus has shifted in recent years to the development of point-of-care diagnostics for various vector-borne diseases in humans and animals, little research effort has been devoted to their integration into vector surveillance and control programs, particularly in resource-challenged countries. One technology which may be helpful for large scale vector surveillance initiatives is loop-mediated isothermal amplification (LAMP). The aim of this study was to develop a LAMP assay to detect spotted fever group (SFG) rickettsia DNA from field-collected ticks and fleas and compare with published end-point PCR results. A Spotted Fever Group rickettsia-specific loop-mediated isothermal amplification (SFGR-LAMP) assay was developed using primers based on a region of the R. rickettsii 17kDa protein gene. The sensitivity, specificity, and reproducibility of the assay were evaluated. The assay was then compared with the results of end-point PCR assays for pooled tick and flea samples obtained from field-based surveillance studies. The sensitivity of the SFGR-LAMP assay was 0.00001 ng/μl (25μl volume) which was 10 times more sensitive than the 17kDa protein gene end-point PCR used as the reference method. The assay only recognized gDNA from SFG and transitional group (TRG) rickettsia species tested but did not detect gDNA from typhus group (TG) rickettsia species or closely or distantly related bacterial species. The SFGR-LAMP assay detected the same positives from a set of pooled tick and flea samples detected by end-point PCR in addition to two pooled flea samples not detected by end-point PCR. To our knowledge, this is the first study to develop a functional LAMP assay to initially screen for SFG and TRG rickettsia pathogens in field-collected ticks and fleas. With a high sensitivity and specificity, the results indicate the potential use as a field-based surveillance tool for tick and flea-borne rickettsial pathogens in resource-challenged countries.
Multidimensional severity assessment in bronchiectasis: an analysis of seven European cohorts.
McDonnell, M J; Aliberti, S; Goeminne, P C; Dimakou, K; Zucchetti, S C; Davidson, J; Ward, C; Laffey, J G; Finch, S; Pesci, A; Dupont, L J; Fardon, T C; Skrbic, D; Obradovic, D; Cowman, S; Loebinger, M R; Rutherford, R M; De Soyza, A; Chalmers, J D
2016-12-01
Bronchiectasis is a multidimensional disease associated with substantial morbidity and mortality. Two disease-specific clinical prediction tools have been developed, the Bronchiectasis Severity Index (BSI) and the FACED score, both of which stratify patients into severity risk categories to predict the probability of mortality. We aimed to compare the predictive utility of BSI and FACED in assessing clinically relevant disease outcomes across seven European cohorts independent of their original validation studies. The combined cohorts totalled 1612. Pooled analysis showed that both scores had a good discriminatory predictive value for mortality (pooled area under the curve (AUC) 0.76, 95% CI 0.74 to 0.78 for both scores) with the BSI demonstrating a higher sensitivity (65% vs 28%) but lower specificity (70% vs 93%) compared with the FACED score. Calibration analysis suggested that the BSI performed consistently well across all cohorts, while FACED consistently overestimated mortality in 'severe' patients (pooled OR 0.33 (0.23 to 0.48), p<0.0001). The BSI accurately predicted hospitalisations (pooled AUC 0.82, 95% CI 0.78 to 0.84), exacerbations, quality of life (QoL) and respiratory symptoms across all risk categories. FACED had poor discrimination for hospital admissions (pooled AUC 0.65, 95% CI 0.63 to 0.67) with low sensitivity at 16% and did not consistently predict future risk of exacerbations, QoL or respiratory symptoms. No association was observed with FACED and 6 min walk distance (6MWD) or lung function decline. The BSI accurately predicts mortality, hospital admissions, exacerbations, QoL, respiratory symptoms, 6MWD and lung function decline in bronchiectasis, providing a clinically relevant evaluation of disease severity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Ablordeppey, Enyo A.; Drewry, Anne M.; Beyer, Alexander B.; Theodoro, Daniel L.; Fowler, Susan A.; Fuller, Brian M.; Carpenter, Christopher R.
2016-01-01
Objective We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared to chest radiography. Data Sources PubMed, EMBASE, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov Study Selection Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2×2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, inter-rater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. Data Extraction Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Data Synthesis 15 studies with 1553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 [0.77, 0.86] and 0.98 [0.97, 0.99] respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 [14.72, 65.78] and 0.25 [0.13, 0.47]. The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. Conclusions Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than chest radiography. PMID:27922877
McGrath, Trevor A; McInnes, Matthew D F; Korevaar, Daniël A; Bossuyt, Patrick M M
2016-10-01
Purpose To determine whether authors of systematic reviews of diagnostic accuracy studies published in imaging journals used recommended methods for meta-analysis, and to evaluate the effect of traditional methods on summary estimates of sensitivity and specificity. Materials and Methods Medline was searched for published systematic reviews that included meta-analysis of test accuracy data limited to imaging journals published from January 2005 to May 2015. Two reviewers independently extracted study data and classified methods for meta-analysis as traditional (univariate fixed- or random-effects pooling or summary receiver operating characteristic curve) or recommended (bivariate model or hierarchic summary receiver operating characteristic curve). Use of methods was analyzed for variation with time, geographical location, subspecialty, and journal. Results from reviews in which study authors used traditional univariate pooling methods were recalculated with a bivariate model. Results Three hundred reviews met the inclusion criteria, and in 118 (39%) of those, authors used recommended meta-analysis methods. No change in the method used was observed with time (r = 0.54, P = .09); however, there was geographic (χ(2) = 15.7, P = .001), subspecialty (χ(2) = 46.7, P < .001), and journal (χ(2) = 27.6, P < .001) heterogeneity. Fifty-one univariate random-effects meta-analyses were reanalyzed with the bivariate model; the average change in the summary estimate was -1.4% (P < .001) for sensitivity and -2.5% (P < .001) for specificity. The average change in width of the confidence interval was 7.7% (P < .001) for sensitivity and 9.9% (P ≤ .001) for specificity. Conclusion Recommended methods for meta-analysis of diagnostic accuracy in imaging journals are used in a minority of reviews; this has not changed significantly with time. Traditional (univariate) methods allow overestimation of diagnostic accuracy and provide narrower confidence intervals than do recommended (bivariate) methods. (©) RSNA, 2016 Online supplemental material is available for this article.
Martins, Luís Miguel Lourenço; Marques, Andreia Grilo; Pereira, Luísa Maria Dotti Silva; Goicoa, Ana; Semião-Santos, Saul José; Bento, Ofélia Pereira
2015-04-01
Specific immunotherapy has shown to be very useful for allergy control in dogs, with a common success rate ranging from 65% to 70%. However, this efficacy could probably be improved and the identification of individual allergomes, with the choice of more adequate molecular allergen pools for specific immunotherapy, being the strategy. To map Dermatophagoides pteronyssinus (Der p) allergens for mite-sensitized atopic dogs, for better understanding how individual allergograms may influence the response to house-dust mite immunotherapy. To identify the Der p mite allergome for dogs, 20 individuals allergic to dust-mites and sensitized to Der p, were selected. The extract from Der p was submitted to isoelectric focusing (IEF), one-dimensional (1-D) and two-dimensional (2-D) sodium dodecyl sulphate polyacrylamide gel electrophoresis (SDS-PAGE). Separated proteins were blotted onto polyvinylidene difluoride (PVDF) membranes and immunoblottings were performed with patient sera. Allergen-bound specific IgE was detected. Eleven allergens were identified from isoelectric focusing (IEF), as well as from 1-D SDS PAGE. From 2-D SDS-PAGE, 24 spots were identified. Several similarities were found between dog and human allergograms and no absolute correlation between sensitization and allergy was observed either. As in humans, different individual allergograms do not seem to implicate different clinical patterns, but may influence the response to specific immunotherapy. The molecular epidemiology approach in veterinary allergy management, by the characterization of individual patients' allergoms and by choosing the best molecular allergen pool for each patient could also improve the efficacy of allergy immunotherapy.
Sakaguchi, M; Hori, H; Hattori, S; Irie, S; Imai, A; Yanagida, M; Miyazawa, H; Toda, M; Inouye, S
1999-09-01
Anaphylactic reactions to measles, mumps, and rubella vaccines, including gelatin as a stabilizer, have been reported. It had been found that most of these reactions to live vaccines are caused by the bovine gelatin included in these vaccines. Gelatin mainly includes denatured type I collagen, which consists of alpha1 and alpha2 chains. The current study was designed to investigate the IgE reactivity to alpha1 and alpha2 chains of bovine type I collagen in gelatin-sensitive children. Serum samples were taken from 10 children who had anaphylaxis to the vaccines and high levels of specific IgE to bovine gelatin. Bovine type I collagen was isolated from bovine skin and then separated to alpha1 and alpha2 chains by column chromatography. IgE reactivity to denatured type I collagen and its alpha1 and alpha2 chains was analyzed by immunoblotting, ELISA, and histamine release from the mast cells passive sensitized with IgE antibodies in pooled serum of the children. All children had specific IgE to bovine type I collagen. Furthermore, IgE antibodies in their sera reacted with the alpha;2 chain but not with the alpha1 chain. Similarly, the mast cells sensitized with pooled sera in the children showed alpha2 chain-specific histamine release but not alpha1 chain-specific histamine release. In gelatin allergy denatured bovine type I collagen is a major allergen and IgE-binding sites exist in the alpha2 chain of type I collagen.
Yin, Xinxin; Wang, Jiali; Zheng, Wen; Ma, Jingjing; Hao, Panpan; Chen, Yuguo
2016-07-01
Both coronary computed tomography angiography (CCTA) and exercise electrocardiography (ExECG) are non-invasive testing methods for the evaluation of coronary artery disease (CAD). However, there was controversy on the diagnostic performance of these methods due to the limited data in each single study. Therefore, we performed a meta-analysis to address these issues. We searched PubMed and Embase databases up to May 22, 2015. Two authors identified eligible studies, extracted data and accessed quality. Pooled estimation of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), summary receiver-operating characteristic curve (SROC) and the area under curve (AUC) of CCTA and ExECG for the diagnosis of CAD were calculated using Stata, Meta-Disc and Review Manager statistical software. Seven articles were included. Pooled sensitivity of CCTA and ExECG were 0.98 [95% confidence intervals (CIs): 0.95-0.99] and 0.66 (95% CIs: 0.59-0.72); pooled specificity of CCTA and ExECG were 0.84 (95% CIs: 0.81-0.87) and 0.75 (95% CIs: 0.71-0.79); pooled DOR of CCTA and ExECG were 110.24 (95% CIs: 35.07-346.55) and 6.28 (95% CIs: 2.06-19.13); and AUC of CCTA and ExECG were 0.9950±0.0046 and 0.7727±0.0638, respectively. There is no heterogeneity caused by threshold effect in CCTA or ExECG analysis. The Deeks' test showed no potential publication bias (P=0.17). CCTA has better diagnostic performance than ExECG in the evaluation of CAD, which can provide a better solution for the clinical problem of the diagnosis for CAD.
Russo, Giorgio Ivan; Regis, Federica; Castelli, Tommaso; Favilla, Vincenzo; Privitera, Salvatore; Giardina, Raimondo; Cimino, Sebastiano; Morgia, Giuseppe
2017-08-01
Markers for prostate cancer (PCa) have progressed over recent years. In particular, the prostate health index (PHI) and the 4-kallikrein (4K) panel have been demonstrated to improve the diagnosis of PCa. We aimed to review the diagnostic accuracy of PHI and the 4K panel for PCa detection. We performed a systematic literature search of PubMed, EMBASE, Cochrane, and Academic One File databases until July 2016. We included diagnostic accuracy studies that used PHI or 4K panel for the diagnosis of PCa or high-grade PCa. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Twenty-eight studies including 16,762 patients have been included for the analysis. The pooled data showed a sensitivity of 0.89 and 0.74 for PHI and 4K panel, respectively, for PCa detection and a pooled specificity of 0.34 and 0.60 for PHI and 4K panel, respectively. The derived area under the curve (AUC) from the hierarchical summary receiver operating characteristic (HSROC) showed an accuracy of 0.76 and 0.72 for PHI and 4K panel respectively. For high-grade PCa detection, the pooled sensitivity was 0.93 and 0.87 for PHI and 4K panel, respectively, whereas the pooled specificity was 0.34 and 0.61 for PHI and 4K panel, respectively. The derived AUC from the HSROC showed an accuracy of 0.82 and 0.81 for PHI and 4K panel, respectively. Both PHI and the 4K panel provided good diagnostic accuracy in detecting overall and high-grade PCa. Copyright © 2016 Elsevier Inc. All rights reserved.
Pooling-analysis for diagnostic and prognostic value of MiRNA-100 in various cancers.
Dou, Zhe; Lin, Shuai; Dai, Cong; Lu, Ye; Tian, Tian; Wang, Meng; Liu, Xinghan; Zheng, Yi; Xu, Peng; Li, Shanli; Sheng, Qianwen; Deng, Yujiao; Dai, Zhijun
2017-09-22
Many studies manifested miRNA-100 was deregulated in various cancers, which indicated that miRNA-100 might be a potential biomarker of cancer diagnosis and prognosis. However, the role of miRNA-100 was still uncertain. We searched for qualified studies using PubMed, EMBASE, Web of Science, Cochrane library and CNKI databases. The diagnostic effect was evaluated by the pooled sensitivity, specificity, and other indexes. Pooled hazard ratios (HRs) with 95% confidence intervals (CIs) for overall survival (OS) were calculated to assess the prognostic value. This meta-analysis included 7 and 19 studies about diagnosis and prognosis, respectively. The results of pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odds ratio (DOR) were 0.75 (95%CI: 0.71-0.78), 0.74 (95%CI: 0.69-0.78), 2.61 (95%CI: 1.81-3.76), 0.33 (95%CI: 0.24-0.45), 8.46 (95%CI: 4.85-14.77), respectively. And, the area under SROC curve (AUC) was 0.8141. We also found that lower expression of miRNA-100 in cancer tissues could significantly predict poorer prognosis in overall cancer (HR = 0.59, 95%CI: 0.39-0.90), especially in genital system tumors (HR = 0.42, 95%CI: 0.27-0.66, P = 0.431), bladder cancer (HR = 0.21, 95%CI: 0.06-0.73, P = 0.143) and esophageal squamous cell carcinoma (HR = 0.26, 95%CI: 0.13-0.52, P = 0.164). Our studies concluded that miRNA-100 has a certain value in diagnosis and it may indicate a poor prognosis of cancers.
Helsen, Nils; Van den Wyngaert, Tim; Carp, Laurens; Stroobants, Sigrid
2018-06-01
18-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) is increasingly used to evaluate treatment response in head and neck squamous cell carcinoma (HNSCC). This analysis assessed the diagnostic value of FDG-PET/CT in detecting nodal disease within 6 months after treatment, considering patient and disease characteristics. A systematic review was performed using the MEDLINE and Web of Knowledge databases. The results were pooled using a bivariate random effects model of the sensitivity and specificity. Out of 22 identified studies, a meta-analysis of 20 studies (1293 patients) was performed. The pooled estimates of sensitivity, specificity and diagnostic odds ratio (with 95% CI) were 85% (76-91%), 93% (89-96%) and 76 (35-165), respectively. With the prevalence set at 10%, the positive and negative predictive values were 58% and 98%. There was significant heterogeneity between the trials (p < 0.001). HPV positive tumors were associated with lower sensitivity (75% vs 89%; p = 0.01) and specificity (87% vs 95%; p < 0.005). FDG-PET/CT within 6 months after (chemo)radiotherapy in HNSCC patients is a reliable method for ruling out residual/recurrent nodal disease and obviates the need for therapeutic intervention. However, FDG-PET/CT may be less reliable in HPV positive tumors and the optimal surveillance strategy remains to be determined.
Noll, Lance W; Baumgartner, William C; Shridhar, Pragathi B; Cull, Charley A; Dewsbury, Diana M; Shi, Xiaorong; Cernicchiaro, Natalia; Renter, David G; Nagaraja, T G
2016-01-01
Shiga toxin-producing Escherichia coli (STEC) of the serogroups O26, O45, O103, O111, O121, and O145, often called non-O157 STEC, are foodborne pathogens. Cattle are asymptomatic reservoirs for STEC; the organisms reside in the hindgut and are shed in the feces, which serve as the source of food product contaminations. Culture-based detection of non-O157 STEC involves an immunomagnetic separation (IMS) step to capture the specific serogroups in complex matrices, such as feces. The IMS procedure is time consuming and labor intensive because of the need to subject each fecal sample to six individual beads. Therefore, our objective was to evaluate whether pooling of IMS beads affects sensitivity of non-O157 STEC detection compared with using individual IMS beads. The evaluation was done by comparing detection of serogroups in feces spiked with pure cultures (experiments 1 and 2) and from feces (n = 384) of naturally shedding cattle (experiment 3). In spiked fecal samples, detection with pools of three, four, six, or seven beads was similar to, or at times higher than, detection with individual IMS beads. In experiment 3, the proportions of fecal samples that tested positive for the six serogroups as detected by individual or pooled beads were similar. Based on noninferiority tests, detection with pooled beads was not substantially inferior to detection with individual beads (P > 0.05). In conclusion, the pooling of IMS beads is a better option for detection of STEC serogroups in fecal samples compared with individual beads because the procedure saves time and labor and has the prospect of a higher throughput.
Peters, Philip J; Westheimer, Emily; Cohen, Stephanie; Hightow-Weidman, Lisa B; Moss, Nicholas; Tsoi, Benjamin; Hall, Laura; Fann, Charles; Daskalakis, Demetre C; Beagle, Steve; Patel, Pragna; Radix, Asa; Foust, Evelyn; Kohn, Robert P; Marmorino, Jenni; Pandori, Mark; Fu, Jie; Samandari, Taraz; Gay, Cynthia L
2016-02-16
Although acute HIV infection contributes disproportionately to onward HIV transmission, HIV testing has not routinely included screening for acute HIV infection. To evaluate the performance of an HIV antigen/antibody (Ag/Ab) combination assay to detect acute HIV infection compared with pooled HIV RNA testing. Multisite, prospective, within-individual comparison study conducted between September 2011 and October 2013 in 7 sexually transmitted infection clinics and 5 community-based programs in New York, California, and North Carolina. Participants were 12 years or older and seeking HIV testing, without known HIV infection. All participants with a negative rapid HIV test result were screened for acute HIV infection with an HIV Ag/Ab combination assay (index test) and pooled human immunodeficiency virus 1 (HIV-1) RNA testing. HIV RNA testing was the reference standard, with positive reference standard result defined as detectable HIV-1 RNA on an individual RNA test. Number and proportion with acute HIV infections detected. Among 86,836 participants with complete test results (median age, 29 years; 75.0% men; 51.8% men who have sex with men), established HIV infection was diagnosed in 1158 participants (1.33%) and acute HIV infection was diagnosed in 168 participants (0.19%). Acute HIV infection was detected in 134 participants with HIV Ag/Ab combination testing (0.15% [95% CI, 0.13%-0.18%]; sensitivity, 79.8% [95% CI, 72.9%-85.6%]; specificity, 99.9% [95% CI, 99.9%-99.9%]; positive predictive value, 59.0% [95% CI, 52.3%-65.5%]) and in 164 participants with pooled HIV RNA testing (0.19% [95% CI, 0.16%-0.22%]; sensitivity, 97.6% [95% CI, 94.0%-99.4%]; specificity, 100% [95% CI, 100%-100%]; positive predictive value, 96.5% [95% CI, 92.5%-98.7%]; sensitivity comparison, P < .001). Overall HIV Ag/Ab combination testing detected 82% of acute HIV infections detectable by pooled HIV RNA testing. Compared with rapid HIV testing alone, HIV Ag/Ab combination testing increased the relative HIV diagnostic yield (both established and acute HIV infections) by 10.4% (95% CI, 8.8%-12.2%) and pooled HIV RNA testing increased the relative HIV diagnostic yield by 12.4% (95% CI, 10.7%-14.3%). In a high-prevalence population, HIV screening using an HIV Ag/Ab combination assay following a negative rapid test detected 82% of acute HIV infections detectable by pooled HIV RNA testing, with a positive predictive value of 59%. Further research is needed to evaluate this strategy in lower-prevalence populations and in persons using preexposure prophylaxis for HIV prevention.
de Freitas, Daniel Roberto Coradi; Gomes, Luciano Teixeira; Fontes, Cor Jesus F; Tauil, Pedro Luiz; Pang, Lorrin W; Duarte, Elisabeth Carmen
2014-04-01
Transfusion-transmitted malaria is a severe disease with high fatality rate. Most Brazilian blood banks in the Amazon region perform malaria screening using microscopic examination (thick smears). Since low parasite concentrations are expected in asymptomatic blood donors a high sensitivity test should be used for donor screening. This study determined the sensitivity of a nested-PCR for plasmodium detection in pooled samples. We performed a one-stage criterion validation study with 21 positive samples pooled with samples from ten negative volunteer until three different concentrations were reached (0.33; 0.25; 0.20 parasites/μL - p/μL). Nested PCR was performed as described by Snounou et al. (1993). Sensitivities (and confidence intervals) were determined by stratum of final parasite concentration on the pooled samples. All samples with parasitemia values of 0.33 and 0.25 p/μL had 100% sensitivity (95%CI=86.3-100). One negative result was obtained from a sample with 0.20 p/μL sensitivity=95.2% (95%CI=76.2-99.9). Compared to parasitemia detectable under ideal conditions of thick smear, this nested-PCR in pooled sample was able to detect 40 times more parasites per microliter. Nested-PCR in pooled samples should be considered as a high sensitive alternative to thick smear for donor screening in blood banks at endemic regions. Local authorities need to assess cost:benefit advantages of this method compared to alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.
Jin, Sheng Chih; Benitez, Bruno A; Deming, Yuetiva; Cruchaga, Carlos
2016-01-01
Analyses of genome-wide association studies (GWAS) for complex disorders usually identify common variants with a relatively small effect size that only explain a small proportion of phenotypic heritability. Several studies have suggested that a significant fraction of heritability may be explained by low-frequency (minor allele frequency (MAF) of 1-5 %) and rare-variants that are not contained in the commercial GWAS genotyping arrays (Schork et al., Curr Opin Genet Dev 19:212, 2009). Rare variants can also have relatively large effects on risk for developing human diseases or disease phenotype (Cruchaga et al., PLoS One 7:e31039, 2012). However, it is necessary to perform next-generation sequencing (NGS) studies in a large population (>4,000 samples) to detect a significant rare-variant association. Several NGS methods, such as custom capture sequencing and amplicon-based sequencing, are designed to screen a small proportion of the genome, but most of these methods are limited in the number of samples that can be multiplexed (i.e. most sequencing kits only provide 96 distinct index). Additionally, the sequencing library preparation for 4,000 samples remains expensive and thus conducting NGS studies with the aforementioned methods are not feasible for most research laboratories.The need for low-cost large scale rare-variant detection makes pooled-DNA sequencing an ideally efficient and cost-effective technique to identify rare variants in target regions by sequencing hundreds to thousands of samples. Our recent work has demonstrated that pooled-DNA sequencing can accurately detect rare variants in targeted regions in multiple DNA samples with high sensitivity and specificity (Jin et al., Alzheimers Res Ther 4:34, 2012). In these studies we used a well-established pooled-DNA sequencing approach and a computational package, SPLINTER (short indel prediction by large deviation inference and nonlinear true frequency estimation by recursion) (Vallania et al., Genome Res 20:1711, 2010), for accurate identification of rare variants in large DNA pools. Given an average sequencing coverage of 30× per haploid genome, SPLINTER can detect rare variants and short indels up to 4 base pairs (bp) with high sensitivity and specificity (up to 1 haploid allele in a pool as large as 500 individuals). Step-by-step instructions on how to conduct pooled-DNA sequencing experiments and data analyses are described in this chapter.
The dream of a one-stop-shop: Meta-analysis on myocardial perfusion CT.
Pelgrim, Gert Jan; Dorrius, Monique; Xie, Xueqian; den Dekker, Martijn A M; Schoepf, U Joseph; Henzler, Thomas; Oudkerk, Matthijs; Vliegenthart, Rozemarijn
2015-12-01
To determine the diagnostic performance of computed tomography (CT) perfusion techniques for the detection of functionally relevant coronary artery disease (CAD) in comparison to reference standards, including invasive coronary angiography (ICA), single photon emission computed tomography (SPECT), and magnetic resonance imaging (MRI). PubMed, Web of Knowledge and Embase were searched from January 1, 1998 until July 1, 2014. The search yielded 9475 articles. After duplicate removal, 6041 were screened on title and abstract. The resulting 276 articles were independently analyzed in full-text by two reviewers, and included if the inclusion criteria were met. The articles reporting diagnostic parameters including true positive, true negative, false positive and false negative were subsequently evaluated for the meta-analysis. Results were pooled according to CT perfusion technique, namely snapshot techniques: single-phase rest, single-phase stress, single-phase dual-energy stress and combined coronary CT angiography [rest] and single-phase stress, as well the dynamic technique: dynamic stress CT perfusion. Twenty-two articles were included in the meta-analysis (1507 subjects). Pooled per-patient sensitivity and specificity of single-phase rest CT compared to rest SPECT were 89% (95% confidence interval [CI], 82-94%) and 88% (95% CI, 78-94%), respectively. Vessel-based sensitivity and specificity of single-phase stress CT compared to ICA-based >70% stenosis were 82% (95% CI, 64-92%) and 78% (95% CI, 61-89%). Segment-based sensitivity and specificity of single-phase dual-energy stress CT in comparison to stress MRI were 75% (95% CI, 60-85%) and 95% (95% CI, 80-99%). Segment-based sensitivity and specificity of dynamic stress CT perfusion compared to stress SPECT were 77% (95% CI, 67-85) and 89% (95% CI, 78-95%). For combined coronary CT angiography and single-phase stress CT, vessel-based sensitivity and specificity in comparison to ICA-based >50% stenosis were 84% (95% CI, 67-93%) and 93% (95% CI, 89-96%). This meta-analysis shows considerable variation in techniques and reference standards for CT of myocardial blood supply. While CT seems sensitive and specific for evaluation of hemodynamically relevant CAD, studies so far are limited in size. Standardization of myocardial perfusion CT technique is essential. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Yoon, Jung-Ro; Yang, Se-Hyun; Shin, Young-Soo
2018-06-01
Many studies have found associations between laboratory biomarkers and periprosthetic joint infection (PJI), but it remains unclear whether these biomarkers are clinically useful in ruling out PJI. This meta-analysis compared the performance of interleukin-6 (IL-6) versus procalcitonin (PCT) for the diagnosis of PJI. In this meta-analysis, we reviewed studies that evaluated IL-6 or/and PCT as a diagnostic biomarker for PJI and provided sufficient data to permit sensitivity and specificity analyses for each test. The major databases MEDLINE, EMBASE, the Cochrane Library, Web of Science, and SCOPUS were searched for appropriate studies from the earliest available date of indexing through February 28, 2017. No restrictions were placed on language of publication. We identified 18 studies encompassing a total of 1,835 subjects; 16 studies reported on IL-6 and 6 studies reported on PCT. The area under the curve (AUC) was 0.93 (95% CI, 0.91-0.95) for IL-6 and 0.83 (95% CI, 0.79-0.86) for PCT. The pooled sensitivity was 0.83 (95% CI, 0.74-0.89) for IL-6 and 0.58 (95% CI, 0.31-0.81) for PCT. The pooled specificity was 0.91 (95% CI, 0.84-0.95) for IL-6 and 0.95 (95% CI, 0.63-1.00) for PCT. Both the IL-6 and PCT tests had a high positive likelihood ratio (LR); 9.3 (95% CI, 5.3-16.2) and 12.4 (95% CI, 1.7-89.8), respectively, making them excellent rule-in tests for the diagnosis of PJI. The pooled negative LR for IL-6 was 0.19 (95% CI, 0.12-0.29), making it suitable as a rule-out test, whereas the pooled negative LR for PCT was 0.44 (95% CI, 0.25-0.78), making it unsuitable as a rule-out diagnostic tool. Based on the results of the present meta-analysis, IL-6 has higher diagnostic value than PCT for the diagnosis of PJI. Moreover, the specificity of the IL-6 test is higher than its sensitivity. Conversely, PCT is not recommended for use as a rule-out diagnostic tool.
Lange, Berit; Cohn, Jennifer; Roberts, Teri; Camp, Johannes; Chauffour, Jeanne; Gummadi, Nina; Ishizaki, Azumi; Nagarathnam, Anupriya; Tuaillon, Edouard; van de Perre, Philippe; Pichler, Christine; Easterbrook, Philippa; Denkinger, Claudia M
2017-11-01
Dried blood spots (DBS) are a convenient tool to enable diagnostic testing for viral diseases due to transport, handling and logistical advantages over conventional venous blood sampling. A better understanding of the performance of serological testing for hepatitis C (HCV) and hepatitis B virus (HBV) from DBS is important to enable more widespread use of this sampling approach in resource limited settings, and to inform the 2017 World Health Organization (WHO) guidance on testing for HBV/HCV. We conducted two systematic reviews and meta-analyses on the diagnostic accuracy of HCV antibody (HCV-Ab) and HBV surface antigen (HBsAg) from DBS samples compared to venous blood samples. MEDLINE, EMBASE, Global Health and Cochrane library were searched for studies that assessed diagnostic accuracy with DBS and agreement between DBS and venous sampling. Heterogeneity of results was assessed and where possible a pooled analysis of sensitivity and specificity was performed using a bivariate analysis with maximum likelihood estimate and 95% confidence intervals (95%CI). We conducted a narrative review on the impact of varying storage conditions or limits of detection in subsets of samples. The QUADAS-2 tool was used to assess risk of bias. For the diagnostic accuracy of HBsAg from DBS compared to venous blood, 19 studies were included in a quantitative meta-analysis, and 23 in a narrative review. Pooled sensitivity and specificity were 98% (95%CI:95%-99%) and 100% (95%CI:99-100%), respectively. For the diagnostic accuracy of HCV-Ab from DBS, 19 studies were included in a pooled quantitative meta-analysis, and 23 studies were included in a narrative review. Pooled estimates of sensitivity and specificity were 98% (CI95%:95-99) and 99% (CI95%:98-100), respectively. Overall quality of studies and heterogeneity were rated as moderate in both systematic reviews. HCV-Ab and HBsAg testing using DBS compared to venous blood sampling was associated with excellent diagnostic accuracy. However, generalizability is limited as no uniform protocol was applied and most studies did not use fresh samples. Future studies on diagnostic accuracy should include an assessment of impact of environmental conditions common in low resource field settings. Manufacturers also need to formally validate their assays for DBS for use with their commercial assays.
Yu, Zhiyuan; Zheng, Jun; Guo, Rui; Ma, Lu; Li, Mou; Wang, Xiaoze; Lin, Sen; Li, Hao; You, Chao
2017-12-01
Hematoma expansion is independently associated with poor outcome in intracerebral hemorrhage (ICH). Blend sign is a simple predictor for hematoma expansion on non-contrast computed tomography. However, its accuracy for predicting hematoma expansion is inconsistent in previous studies. This meta-analysis is aimed to systematically assess the performance of blend sign in predicting hematoma expansion in ICH. A systematic literature search was conducted. Original studies about predictive accuracy of blend sign for hematoma expansion in ICH were included. Pooled sensitivity, specificity, positive and negative likelihood ratios were calculated. Summary receiver operating characteristics curve was constructed. Publication bias was assessed by Deeks' funnel plot asymmetry test. A total of 5 studies with 2248 patients were included in this meta-analysis. The pooled sensitivity, specificity, positive and negative likelihood ratios of blend sign for predicting hematoma expansion were 0.28, 0.92, 3.4 and 0.78, respectively. The area under the curve (AUC) was 0.85. No significant publication bias was found. This meta-analysis demonstrates that blend sign is a useful predictor with high specificity for hematoma expansion in ICH. Further studies with larger sample size are still necessary to verify the accuracy of blend sign for predicting hematoma expansion. Copyright © 2017 Elsevier B.V. All rights reserved.
McKenna, S L B; Ritter, C; Dohoo, I; Keefe, G P; Barkema, H W
2018-05-23
In herds with typical moderate to low within-herd prevalence, testing for Mycobacterium avium ssp. paratuberculosis (MAP), the infectious agent of Johne's disease, will be more cost-effective if individual fecal samples are cultured in composite pools. However, sensitivity to classify a pool containing 1 or more positive individual samples as positive may depend on pool size and number of individual positive samples within a pool. Fecal samples collected from 994 dairy cows sampled at slaughter were cultured to detect MAP. Culturing was done both individually and as composite pooled samples using the TREK ESP Culture System II broth medium (Thermo Fisher Scientific, Trek Diagnostic Systems Inc., Cleveland, OH). Composite samples consisted of pools containing feces from 3, 5, 8, 10, or 15 cows. The number of individual fecal culture-positive cows within each pool ranged from 0 to 4. Culture of individual fecal samples detected MAP in 36 (3.6%) of the 994 cows. Individual samples that were detected within the first 50 d by TREK ESP Culture System II were more likely to lead to a positive pool result. In total, 840 pooled fecal samples were examined for presence of MAP, and of those, 272 pools actually contained feces from fecal culture-positive cows. The crude sensitivity (proportion of pools that contained at least 1 fecal-positive cow that tested positive) for pools of 3, 5, 8, 10, and 15 was 47, 67, 44, 59, and 39%, respectively. Across pools, an increase of the number of fecal culture-positive samples from 1 to 2 enhanced overall crude sensitivity from 44 to 71%. However, sensitivity did not further increase for pools with 3 or 4 fecal culture-positive samples (63 and 60%, respectively). Additionally, a simulation analysis assessing probability of pooled fecal samples being positive in herds of 50 and 100 cows was conducted. The simulation assumed that 1, 2, or 5 cows per herd were MAP fecal culture-positive and that pools of 5 and 10 were used. This low-prevalence herd simulation indicated that weighted mean herd probabilities of detecting a positive herd ranged between 52 and 99.3%, with the lowest probability for pools of 10 with 1 positive cow in the herd and the highest probability for pools of 5 with 5 positive cows in the herd. However, overall, pools of 5 and 10 had similar diagnostic capabilities, enabling cost savings by utilizing pools of 10. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Krepel, J; Patel, J; Sproston, A; Hopkins, F; Jang, D; Mahony, J; Chernesky, M
1999-10-01
Nucleic acid amplification testing is the most accurate approach to diagnosing Chlamydia trachomatis infections. Our objective was to compare the accuracy and cost savings of pooling urines as opposed to individual testing. Strategies of pooling urine specimens into groups of four (4x pool) or eight (8x pool) followed by testing the positive pools individually were compared to individual specimen testing to determine if significant cost savingS could be realized without compromising the sensitivity and specificity of the LCx C. trachomatis Assay (Abbott Laboratories, Abbott Park, Chicago, IL) performed in a busy private medical laboratory. A total of 1,220 patient urine samples, 1,187 male (97%) and 33 female (3%), were tested using the normal LCx specimen to cutoff ratio (S/CO) of 1.0 and a decreased S/CO value of 0.2. Individual testing identified 98.2% (109/111) of positive urines. The 4x pooling maneuver identified 92.8% (103/111) of positive patients with the regular cutoff and 96.4% (107/111) when the cutoff was decreased. These values were 95.9% (47/49) and 97.9% (48/49), respectively, when eight urines were pooled. Both pooling and individual testing strategies identified all the negative samples accurately. Cost savings of pooling were calculated to be 44.5% for pools of four and 37.5% for pools of eight, applying the lowered cutoff. Pooling urine specimens for testing with the C. trachomatis LCx system is a simple, accurate, and cost-saving approach that can significantly reduce the cost of amplified nucleic acid testing with minimal sacrifice of testing accuracy.
Minion, Jessica; Leung, Erika; Menzies, Dick; Pai, Madhukar
2010-10-01
Simple, rapid, and affordable tests are needed to detect drug resistance in Mycobacterium tuberculosis. We did a systematic review and meta-analysis to investigate the accuracy of microscopic-observation drug susceptibility (MODS) and thin layer agar (TLA) assays for rapid screening of patients at risk of drug-resistant tuberculosis. In accordance with protocols and methods recommended by the Cochrane Diagnostic Test Accuracy Working Group, we systematically searched PubMed, Embase, and Biosis for reports published between January, 1990, and February, 2009. We included studies investigating detection of drug resistance in M tuberculosis with the MODS or TLA assay, and in which an accepted reference standard was used. Data extracted from the studies were combined by use of bivariate random-effects regression models and hierarchical summary receiver operating characteristic curves to estimate sensitivity and specificity for detection of resistance to specific drugs. We identified 12 studies, of which nine investigated the MODS assay and three investigated the TLA assay. For the MODS assay of rifampicin resistance, pooled estimates were 98·0% (95% CI 94·5-99·3) for sensitivity and 99·4% (95·7-99·9) for specificity. For the MODS assay of isoniazid resistance with a 0·1 μg/mL cutoff, pooled sensitivity was 97·7% (94·4-99·1) and pooled specificity was 95·8% (88·1-98·6), but with a 0·4 μg/mL cutoff, sensitivity decreased to 90·0% (84·5-93·7) and specificity increased to 98·6% (96·9-99·4). All assessments of rifampicin and isoniazid resistance with the TLA assay yielded 100% accuracy. Mean turnaround time was 9·9 days (95% CI 4·1-15·8) for the MODS assay and 11·1 days (10·1-12·0) for the TLA assay. MODS and TLA assays are inexpensive, rapid alternatives to conventional methods for drug susceptibility testing of M tuberculosis. Our data and expert opinion informed WHO's recommendation for use of selected non-commercial drug susceptibility tests, including MODS, as an interim solution until capacity for genotypic or automated liquid culture drug susceptibility testing is developed. Stop TB Department of WHO. Copyright © 2010 Elsevier Ltd. All rights reserved.
Taylor-Phillips, Sian; Freeman, Karoline; Geppert, Julia; Agbebiyi, Adeola; Uthman, Olalekan A; Madan, Jason; Clarke, Angus; Quenby, Siobhan; Clarke, Aileen
2016-01-18
To measure test accuracy of non-invasive prenatal testing (NIPT) for Down, Edwards and Patau syndromes using cell-free fetal DNA and identify factors affecting accuracy. Systematic review and meta-analysis of published studies. PubMed, Ovid Medline, Ovid Embase and the Cochrane Library published from 1997 to 9 February 2015, followed by weekly autoalerts until 1 April 2015. English language journal articles describing case-control studies with ≥ 15 trisomy cases or cohort studies with ≥ 50 pregnant women who had been given NIPT and a reference standard. 41, 37 and 30 studies of 2012 publications retrieved were included in the review for Down, Edwards and Patau syndromes. Quality appraisal identified high risk of bias in included studies, funnel plots showed evidence of publication bias. Pooled sensitivity was 99.3% (95% CI 98.9% to 99.6%) for Down, 97.4% (95.8% to 98.4%) for Edwards, and 97.4% (86.1% to 99.6%) for Patau syndrome. The pooled specificity was 99.9% (99.9% to 100%) for all three trisomies. In 100,000 pregnancies in the general obstetric population we would expect 417, 89 and 40 cases of Downs, Edwards and Patau syndromes to be detected by NIPT, with 94, 154 and 42 false positive results. Sensitivity was lower in twin than singleton pregnancies, reduced by 9% for Down, 28% for Edwards and 22% for Patau syndrome. Pooled sensitivity was also lower in the first trimester of pregnancy, in studies in the general obstetric population, and in cohort studies with consecutive enrolment. NIPT using cell-free fetal DNA has very high sensitivity and specificity for Down syndrome, with slightly lower sensitivity for Edwards and Patau syndrome. However, it is not 100% accurate and should not be used as a final diagnosis for positive cases. CRD42014014947. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Guo, Yongfei; Li, Wenjuan; Cai, Wenli; Zhang, Yi; Fang, Yijie; Hong, Guobin
2017-01-01
Objective: The purpose of this study was to systematically review the diagnostic performance of gadoxetic acid-enhanced magnetic resonance imaging (Gd-EOB-DTPA-MRI) for differentiation of hepatocellular adenoma (HCA) and focal nodular hyperplasia (FNH), as well as HCA classification by using the low signal intensity (SI) in the hepatobiliary phase (HBP). Methods: A systematic process was used to review all published data in MEDLINE database about Gd-EOB-DTPA-MRI applied to differentiation of HCA and FNH, and classification of HCA by using low SI in the HBP. The pooled sensitivity and specificity were calculated to assess the diagnostic value of low SI in the HBP. Results: A review of 45 articles identified 10 eligible studies with a total of 288 HCA lesions. The pooled proportion of low SI in the HBP of HCA were 91% (95% CI: 0.81-0.97). In specific, the subtypes of HCA were 75% (95% CI: 0.64-0.85) for I-HCA, 100% (95% CI: 0.95-1.00) for H-HCA, 92% (95% CI: 0.70-1.00) for U-HCA, and 59% (95% CI: 0.00-1.00) for b-HCA, respectively. The pooled specificity and sensitivity of low SI in the HBP for distinguishing FNH from HCA were 95% (95% CI: 0.92-0.98) and 92% (95% CI: 0.87-0.96), respectively. Conclusion: Low SI in the HBP of Gd-EOB-DTPA-MRI is associated with higher accuracy for distinguishing HCA from FNH. However, the diagnostic accuracy may be overvalued, especially for the diagnosis of subtypes of b-HCA and I-HCA. Therefore, the risk factors and conventional imaging findings should be take into account simultaneously.
Guo, Yongfei; Li, Wenjuan; Cai, Wenli; Zhang, Yi; Fang, Yijie; Hong, Guobin
2017-01-01
Objective: The purpose of this study was to systematically review the diagnostic performance of gadoxetic acid-enhanced magnetic resonance imaging (Gd-EOB-DTPA-MRI) for differentiation of hepatocellular adenoma (HCA) and focal nodular hyperplasia (FNH), as well as HCA classification by using the low signal intensity (SI) in the hepatobiliary phase (HBP). Methods: A systematic process was used to review all published data in MEDLINE database about Gd-EOB-DTPA-MRI applied to differentiation of HCA and FNH, and classification of HCA by using low SI in the HBP. The pooled sensitivity and specificity were calculated to assess the diagnostic value of low SI in the HBP. Results: A review of 45 articles identified 10 eligible studies with a total of 288 HCA lesions. The pooled proportion of low SI in the HBP of HCA were 91% (95% CI: 0.81-0.97). In specific, the subtypes of HCA were 75% (95% CI: 0.64-0.85) for I-HCA, 100% (95% CI: 0.95-1.00) for H-HCA, 92% (95% CI: 0.70-1.00) for U-HCA, and 59% (95% CI: 0.00-1.00) for b-HCA, respectively. The pooled specificity and sensitivity of low SI in the HBP for distinguishing FNH from HCA were 95% (95% CI: 0.92-0.98) and 92% (95% CI: 0.87-0.96), respectively. Conclusion: Low SI in the HBP of Gd-EOB-DTPA-MRI is associated with higher accuracy for distinguishing HCA from FNH. However, the diagnostic accuracy may be overvalued, especially for the diagnosis of subtypes of b-HCA and I-HCA. Therefore, the risk factors and conventional imaging findings should be take into account simultaneously. PMID:28824299
Schueler, Sabine; Walther, Stefan; Schuetz, Georg M; Schlattmann, Peter; Dewey, Marc
2013-06-01
To evaluate the methodological quality of diagnostic accuracy studies on coronary computed tomography (CT) angiography using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) tool. Each QUADAS item was individually defined to adapt it to the special requirements of studies on coronary CT angiography. Two independent investigators analysed 118 studies using 12 QUADAS items. Meta-regression and pooled analyses were performed to identify possible effects of methodological quality items on estimates of diagnostic accuracy. The overall methodological quality of coronary CT studies was merely moderate. They fulfilled a median of 7.5 out of 12 items. Only 9 of the 118 studies fulfilled more than 75 % of possible QUADAS items. One QUADAS item ("Uninterpretable Results") showed a significant influence (P = 0.02) on estimates of diagnostic accuracy with "no fulfilment" increasing specificity from 86 to 90 %. Furthermore, pooled analysis revealed that each QUADAS item that is not fulfilled has the potential to change estimates of diagnostic accuracy. The methodological quality of studies investigating the diagnostic accuracy of non-invasive coronary CT is only moderate and was found to affect the sensitivity and specificity. An improvement is highly desirable because good methodology is crucial for adequately assessing imaging technologies. • Good methodological quality is a basic requirement in diagnostic accuracy studies. • Most coronary CT angiography studies have only been of moderate design quality. • Weak methodological quality will affect the sensitivity and specificity. • No improvement in methodological quality was observed over time. • Authors should consider the QUADAS checklist when undertaking accuracy studies.
Fernlund, E; Liuba, P; Carlson, J; Platonov, P G; Schlegel, T T
2016-01-01
The conventional ECG is commonly used to screen for hypertrophic cardiomyopathy (HCM), but up to 25% of adults and possibly larger percentages of children with HCM have no distinctive abnormalities on the conventional ECG, whereas 5 to 15% of healthy young athletes do. Recently, a 5-min resting advanced 12-lead ECG test ("A-ECG score") showed superiority to pooled criteria from the strictly conventional ECG in correctly identifying adult HCM. The purpose of this study was to evaluate whether in children and young adults, A-ECG scoring could detect echocardiographic HCM associated with the MYBPC3 genetic mutation with greater sensitivity than conventional ECG criteria and distinguish healthy young controls and athletes from persons with MYBPC3 HCM with greater specificity. Five-minute 12-lead ECGs were obtained from 15 young patients (mean age 13.2years, range 0-30years) with MYBPC3 mutation and phenotypic HCM. The conventional and A-ECG results of these patients were compared to those of 198 healthy children and young adults (mean age 13.2, range 1month-30years) with unremarkable echocardiograms, and to those of 36 young endurance-trained athletes, 20 of whom had athletic (physiologic) left ventricular hypertrophy. Compared with commonly used, age-specific pooled criteria from the conventional ECG, a retrospectively generated A-ECG score incorporating results from just 2 derived vectorcardiographic parameters (spatial QRS-T angle and the change in the vectorcardiographic QRS azimuth angle from the second to the third eighth of the QRS interval) increased the sensitivity of ECG for identifying MYBPC3 HCM from 46% to 87% (p<0.05). Use of the same score also demonstrated superior specificity in a set of 198 healthy controls (94% vs. 87% for conventional ECG criteria; p<0.01) including in a subset of 36 healthy, young endurance-trained athletes (100% vs. 69% for conventional ECG criteria, p<0.001). In children and young adults, a 2-parameter 12-lead A-ECG score is retrospectively significantly more sensitive and specific than pooled, age-specific conventional ECG criteria for detecting MYBPC3-HCM and in distinguishing such patients from healthy controls, including endurance-trained athletes. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Cui, Yong; Cao, Wenzhou; Li, Quan; Shen, Hua; Liu, Chao; Deng, Junpeng; Xu, Jiangfeng; Shao, Qiang
2016-05-01
Previous studies indicate that prostate cancer antigen 3 (PCA3) is highly expressed in prostatic tumors. However, its clinical value has not been characterized. The aim of this study was to investigate the clinical value of the urine PCA3 test in the diagnosis of prostate cancer by pooling the published data. Clinical trials utilizing the urine PCA3 test for diagnosing prostate cancer were retrieved from PubMed and Embase. A total of 46 clinical trials including 12,295 subjects were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (-LR), diagnostic odds ratio (DOR) and area under the curve (AUC) were 0.65 (95% confidence interval [CI]: 0.63-0.66), 0.73 (95% CI: 0.72-0.74), 2.23 (95% CI: 1.91-2.62), 0.48 (95% CI: 0.44-0.52), 5.31 (95% CI: 4.19-6.73) and 0.75 (95% CI: 0.74-0.77), respectively. In conclusion, the urine PCA3 test has acceptable sensitivity and specificity for the diagnosis of prostate cancer and can be used as a non-invasive method for that purpose.
Cui, Zhaolei; Xiao, Zhenzhou; Hu, Minhua; Jiang, Chuanhui; Lin, Yingying; Chen, Yansong
2016-01-01
Background Epigenetic alterations of gene or DNA methylation have been highlighted as promising biomarkers for early cervical cancer screening. Herein, we evaluated the diagnostic performance of paired boxed gene 1 (PAX1) and sex determining region Y-box 1 (SOX1) methylation for cervical cancer detection. Methods Eligible studies were retrieved by searching the electronic databases. Study quality was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) checklist. The bivariate meta-analysis model was employed to plot the summary receiver operator characteristic (SROC) curve using Stata 12.0 software. Results The pooled sensitivity of PAX1 methylation was estimated to be 0.73 [95% confidence interval (CI): 0.70–0.75] in differentiating patients with HSIL (high-grade squamous intraepithelial lesion) or CIN3+ (cervical intraepithelial neoplasia type III/worse) or cervical cancer from normal individuals, corresponding to a specificity of 0.87 (95% CI: 0.85–0.89) and area under the curve (AUC) of 0.91. The SOX1 methylation test yielded an AUC of 0.82, under which, the pooled sensitivity was 0.71 (95% CI: 0.67–0.74) and specificity was 0.64 (95% CI: 0.61–0.67). Notably, the stratified analysis suggested that combing parallel testing of PAX1 methylation and human papillomavirus (HPV) DNA (AUC, sensitivity, and specificity of 0.89, 0.75, and 0.81, respectively) achieved higher accuracy than single HPV DNA testing (AUC, sensitivity, and specificity of 0.77, 0.81, and 0.70, respectively). Conclusions PAX1 or SOX1 methylation has a prospect to be an auxiliary biomarker for cervical cancer screening, and parallel testing of PAX1 methylation and HPV DNA in cervical swabs confers an improved diagnostic accuracy than single HPV DNA testing. PMID:27826568
Cherpanath, Thomas G V; Hirsch, Alexander; Geerts, Bart F; Lagrand, Wim K; Leeflang, Mariska M; Schultz, Marcus J; Groeneveld, A B Johan
2016-05-01
Passive leg raising creates a reversible increase in venous return allowing for the prediction of fluid responsiveness. However, the amount of venous return may vary in various clinical settings potentially affecting the diagnostic performance of passive leg raising. Therefore we performed a systematic meta-analysis determining the diagnostic performance of passive leg raising in different clinical settings with exploration of patient characteristics, measurement techniques, and outcome variables. PubMed, EMBASE, the Cochrane Database of Systematic Reviews, and citation tracking of relevant articles. Clinical trials were selected when passive leg raising was performed in combination with a fluid challenge as gold standard to define fluid responders and non-responders. Trials were included if data were reported allowing the extraction of sensitivity, specificity, and area under the receiver operating characteristic curve. Twenty-three studies with a total of 1,013 patients and 1,034 fluid challenges were included. The analysis demonstrated a pooled sensitivity of 86% (95% CI, 79-92), pooled specificity of 92% (95% CI, 88-96), and a summary area under the receiver operating characteristic curve of 0.95 (95% CI, 0.92-0.98). Mode of ventilation, type of fluid used, passive leg raising starting position, and measurement technique did not affect the diagnostic performance of passive leg raising. The use of changes in pulse pressure on passive leg raising showed a lower diagnostic performance when compared with passive leg raising-induced changes in flow variables, such as cardiac output or its direct derivatives (sensitivity of 58% [95% CI, 44-70] and specificity of 83% [95% CI, 68-92] vs sensitivity of 85% [95% CI, 78-90] and specificity of 92% [95% CI, 87-94], respectively; p < 0.001). Passive leg raising retains a high diagnostic performance in various clinical settings and patient groups. The predictive value of a change in pulse pressure on passive leg raising is inferior to a passive leg raising-induced change in a flow variable.
2015-08-01
Diabetes has been defined on the basis of different biomarkers, including fasting plasma glucose (FPG), 2-h plasma glucose in an oral glucose tolerance test (2hOGTT), and HbA1c. We assessed the effect of different diagnostic definitions on both the population prevalence of diabetes and the classification of previously undiagnosed individuals as having diabetes versus not having diabetes in a pooled analysis of data from population-based health examination surveys in different regions. We used data from 96 population-based health examination surveys that had measured at least two of the biomarkers used for defining diabetes. Diabetes was defined using HbA1c (HbA1c ≥6·5% or history of diabetes diagnosis or using insulin or oral hypoglycaemic drugs) compared with either FPG only or FPG-or-2hOGTT definitions (FPG ≥7·0 mmol/L or 2hOGTT ≥11·1 mmol/L or history of diabetes or using insulin or oral hypoglycaemic drugs). We calculated diabetes prevalence, taking into account complex survey design and survey sample weights. We compared the prevalences of diabetes using different definitions graphically and by regression analyses. We calculated sensitivity and specificity of diabetes diagnosis based on HbA1c compared with diagnosis based on glucose among previously undiagnosed individuals (ie, excluding those with history of diabetes or using insulin or oral hypoglycaemic drugs). We calculated sensitivity and specificity in each survey, and then pooled results using a random-effects model. We assessed the sources of heterogeneity of sensitivity by meta-regressions for study characteristics selected a priori. Population prevalence of diabetes based on FPG-or-2hOGTT was correlated with prevalence based on FPG alone (r=0·98), but was higher by 2-6 percentage points at different prevalence levels. Prevalence based on HbA1c was lower than prevalence based on FPG in 42·8% of age-sex-survey groups and higher in another 41·6%; in the other 15·6%, the two definitions provided similar prevalence estimates. The variation across studies in the relation between glucose-based and HbA1c-based prevalences was partly related to participants' age, followed by natural logarithm of per person gross domestic product, the year of survey, mean BMI, and whether the survey population was national, subnational, or from specific communities. Diabetes defined as HbA1c 6·5% or more had a pooled sensitivity of 52·8% (95% CI 51·3-54·3%) and a pooled specificity of 99·74% (99·71-99·78%) compared with FPG 7·0 mmol/L or more for diagnosing previously undiagnosed participants; sensitivity compared with diabetes defined based on FPG-or-2hOGTT was 30·5% (28·7-32·3%). None of the preselected study-level characteristics explained the heterogeneity in the sensitivity of HbA1c versus FPG. Different biomarkers and definitions for diabetes can provide different estimates of population prevalence of diabetes, and differentially identify people without previous diagnosis as having diabetes. Using an HbA1c-based definition alone in health surveys will not identify a substantial proportion of previously undiagnosed people who would be considered as having diabetes using a glucose-based test. Wellcome Trust, US National Institutes of Health. Copyright © 2015 NCD Risk Factor Collaboration. Open Access article distributed under the terms of CC BY. Published by Elsevier Ltd.. All rights reserved.
Li, Bin; Chen, Fei; Liu, Yi; Xu, Guokang
Total joint arthroplasty (TJA) has been one of the most beneficial interventions for treating patients suffering from joint disorders. However, peri-prosthetic joint infection (PJI) is a serious complication that often accompanies TJA and the diagnosis of PJI is remains difficult. Questions remain regarding whether certain biomarkers can be valuable in the diagnosis of PJI. We conducted our systematic review by searching PubMed, Embase, Web of Science, the Cochrane Library, and Science Direct with the key words "periprosthetic joint infection," "synovial fluid," and "α-defensin." Studies that provided sufficient data to construct 2 × 2 contingency tables were chosen based on inclusion and exclusion criteria. The quality of included studies was assessed according to the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria. The pooled sensitivity, specificity, and diagnostic odds ratio (DOR) were calculated for the included studies. The summary receiver operating characteristic (SROC) curve and the area under the summary receiver operating characteristic (AUSROC) were used to evaluate the overall diagnostic performance. Eight studies were included in this systematic review. Among them four articles were included in meta-analysis. A total of 421 participants were studied in the meta-analysis. The pooled sensitivity, specificity, and DOR were 0.98 (95% confidence interval [CI]: 0.94-1.00), 0.97 (95% CI: 0.95-0.99), and 1095.49 (95% CI: 283.68.58-4230.45), respectively. The AUSROC was 0.9949 (standard error [SE] 0.0095). Synovial fluid α-defensin is a biomarker of high sensitivity and specificity for the diagnosis of PJI.
Cytology versus HPV testing for cervical cancer screening in the general population.
Koliopoulos, George; Nyaga, Victoria N; Santesso, Nancy; Bryant, Andrew; Martin-Hirsch, Pierre Pl; Mustafa, Reem A; Schünemann, Holger; Paraskevaidis, Evangelos; Arbyn, Marc
2017-08-10
Cervical cancer screening has traditionally been based on cervical cytology. Given the aetiological relationship between human papillomavirus (HPV) infection and cervical carcinogenesis, HPV testing has been proposed as an alternative screening test. To determine the diagnostic accuracy of HPV testing for detecting histologically confirmed cervical intraepithelial neoplasias (CIN) of grade 2 or worse (CIN 2+), including adenocarcinoma in situ, in women participating in primary cervical cancer screening; and how it compares to the accuracy of cytological testing (liquid-based and conventional) at various thresholds. We performed a systematic literature search of articles in MEDLINE and Embase (1992 to November 2015) containing quantitative data and handsearched the reference lists of retrieved articles. We included comparative test accuracy studies if all women received both HPV testing and cervical cytology followed by verification of the disease status with the reference standard, if positive for at least one screening test. The studies had to include women participating in a cervical cancer screening programme who were not being followed up for previous cytological abnormalities. We completed a 2 x 2 table with the number of true positives (TP), false positives (FP), true negatives (TN), and false negatives for each screening test (HPV test and cytology) used in each study. We calculated the absolute and relative sensitivities and the specificities of the tests for the detection of CIN 2+ and CIN 3+ at various thresholds and computed sensitivity (TP/(TP + TN) and specificity (TN/ (TN + FP) for each test separately. Relative sensitivity and specificity of one test compared to another test were defined as sensitivity of test-1 over sensitivity of test-2 and specificity of test-1 over specificity of test-2, respectively. To assess bias in the studies, we used the Quality Assessment of Diagnostic test Accuracy Studies (QUADAS) tool. We used a bivariate random-effects model for computing pooled accuracy estimates. This model takes into account the within- and between-study variability and the intrinsic correlation between sensitivity and specificity. We included a total of 40 studies in the review, with more than 140,000 women aged between 20 and 70 years old. Many studies were at low risk of bias. There were a sufficient number of included studies with adequate methodology to perform the following test comparisons: hybrid capture 2 (HC2) (1 pg/mL threshold) versus conventional cytology (CC) (atypical squamous cells of undetermined significance (ASCUS)+ and low-grade squamous intraepithelial lesions (LSIL)+ thresholds) or liquid-based cytology (LBC) (ASCUS+ and LSIL+ thresholds), other high-risk HPV tests versus conventional cytology (ASCUS+ and LSIL+ thresholds) or LBC (ASCUS+ and LSIL+ thresholds). For CIN 2+, pooled sensitivity estimates for HC2, CC and LBC (ASCUS+) were 89.9%, 62.5% and 72.9%, respectively, and pooled specificity estimates were 89.9%, 96.6%, and 90.3%, respectively. The results did not differ by age of women (less than or greater than 30 years old), or in studies with verification bias. Accuracy of HC2 was, however, greater in European countries compared to other countries. The results for the sensitivity of the tests were heterogeneous ranging from 52% to 94% for LBC, and 61% to 100% for HC2. Overall, the quality of the evidence for the sensitivity of the tests was moderate, and high for the specificity.The relative sensitivity of HC2 versus CC for CIN 2+ was 1.52 (95% CI: 1.24 to 1.86) and the relative specificity 0.94 (95% CI: 0.92 to 0.96), and versus LBC for CIN 2+ was 1.18 (95% CI: 1.10 to 1.26) and the relative specificity 0.96 (95% CI: 0.95 to 0.97). The relative sensitivity of HC2 versus CC for CIN 3+ was 1.46 (95% CI: 1.12 to 1.91) and the relative specificity 0.95 (95% CI: 0.93 to 0.97). The relative sensitivity of HC2 versus LBC for CIN 3+ was 1.17 (95% CI: 1.07 to 1.28) and the relative specificity 0.96 (95% CI: 0.95 to 0.97). Whilst HPV tests are less likely to miss cases of CIN 2+ and CIN 3+, these tests do lead to more unnecessary referrals. However, a negative HPV test is more reassuring than a negative cytological test, as the cytological test has a greater chance of being falsely negative, which could lead to delays in receiving the appropriate treatment. Evidence from prospective longitudinal studies is needed to establish the relative clinical implications of these tests.
Verhaegh, Pauline; Bavalia, Roisin; Winkens, Bjorn; Masclee, Ad; Jonkers, Daisy; Koek, Ger
2018-06-01
Nonalcoholic fatty liver disease is a rapidly increasing health problem. Liver biopsy analysis is the most sensitive test to differentiate between nonalcoholic steatohepatitis (NASH) and simple steatosis (SS), but noninvasive methods are needed. We performed a systematic review and meta-analysis of noninvasive tests for differentiating NASH from SS, focusing on blood markers. We performed a systematic search of the PubMed, Medline and Embase (1990-2016) databases using defined keywords, limited to full-text papers in English and human adults, and identified 2608 articles. Two independent reviewers screened the articles and identified 122 eligible articles that used liver biopsy as reference standard. If at least 2 studies were available, pooled sensitivity (sens p ) and specificity (spec p ) values were determined using the Meta-Analysis Package for R (metafor). In the 122 studies analyzed, 219 different blood markers (107 single markers and 112 scoring systems) were identified to differentiate NASH from simple steatosis, and 22 other diagnostic tests were studied. Markers identified related to several pathophysiological mechanisms. The markers analyzed in the largest proportions of studies were alanine aminotransferase (sens p , 63.5% and spec p , 74.4%) within routine biochemical tests, adiponectin (sensp, 72.0% and spec p , 75.7%) within inflammatory markers, CK18-M30 (sens p , 68.4% and spec p , 74.2%) within markers of cell death or proliferation and homeostatic model assessment of insulin resistance (sens p , 69.0% and spec p , 72.7%) within the metabolic markers. Two scoring systems could also be pooled: the NASH test (differentiated NASH from borderline NASH plus simple steatosis with 22.9% sens p and 95.3% spec p ) and the GlycoNASH test (67.1% sens p and 63.8% spec p ). In the meta-analysis, we found no test to differentiate NASH from SS with a high level of pooled sensitivity and specificity (≥80%). However, some blood markers, when included in scoring systems in single studies, identified patients with NASH with ≥80% sensitivity and specificity. Replication studies and more standardized study designs are urgently needed. At present, no marker or scoring system can be recommended for use in clinical practice to differentiate NASH from simple steatosis. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
He, Qiqi; Wang, Hanzhang; Kenyon, Jonathan; Liu, Guiming; Yang, Li; Tian, Junqiang; Yue, Zhongjin; Wang, Zhiping
2015-01-01
To use meta-analysis to determine the accuracy of percutaneous core needle biopsy in the diagnosis of small renal masses (SMRs ≤ 4.0 cm). Studies were identified by searching PubMed, Embase, and the Cochrane Library database up to March 2013. Two of the authors independently assessed the study quality using QUADAS-2 tool and extracted data that met the inclusion criteria. The sensitivity, specificity, likelihood ratios, diagnostic odds ratio (DOR) and also summary receiver operating characteristic (SROC) curve were investigated and draw. Deek's funnel plot was used to evaluate the publication bias. A total of 9 studies with 788 patients (803 biopsies) were included. Failed biopsies without repeated or aborted from follow-up/surgery result were excluded (232 patients and 353 biopsies). For all cases, the pooled sensitivity was 94.0% (95% CI: 91.0%, 95.0%), the pooled positive likelihood was 22.57 (95 % CI: 9.20-55.34), the pooled negative likelihood was 0.09 (95 % CI: 0.06-0.13), the pooled DOR was 296.52(95 % CI: 99. 42-884.38). The area under the curve of SROC analysis was 0.959 ± 0.0254. Imaging-guided percutaneous core needle biopsy of small renal masses (SMRs ≤ 4.0 cm) is highly accurate to malignant tumor diagnosis with unknown metastatic status and could be offered to some patients after clinic judgment prior to surgical intervention consideration.
Depression Case Finding in Individuals with Dementia: A Systematic Review and Meta-Analysis.
Goodarzi, Zahra S; Mele, Bria S; Roberts, Derek J; Holroyd-Leduc, Jayna
2017-05-01
To compare the diagnostic accuracy of depression case finding tools with a criterion standard in the outpatient setting among adults with dementia. Systematic review and meta-analysis. Studies of older outpatients with dementia. Elderly outpatients (clinic and long-term care) with dementia (N = 3,035). Prevalence of major depression and diagnostic accuracy measures including sensitivity, specificity, and likelihood ratios. From the 11,539 citations, 20 studies were included for qualitative synthesis and 15 for a meta-analysis. Tools included were the Montgomery Åsberg Depression Rating Scale, Cornell Scale for Depression in Dementia (CSDD), Geriatric Depression Scale (GDS), Center for Epidemiologic Studies Depression Scale (CES-D), Hamilton Depression Rating Scale (HDRS), Single Question, Nijmegen Observer-Rated Depression Scale, and Even Briefer Assessment Scale-Depression. The pooled prevalence of depression in individuals with dementia was 30.3% (95% CI = 22.1-38.5). The average age was 75.2 (95% CI = 71.7-78.7), and mean Mini-Mental State Examination scores ranged from 11.2 to 24. The diagnostic accuracy of the individual tools was pooled for the best-reported cutoffs and for each cutoff, if available. The CSDD had a sensitivity of 0.84 (95% CI = 0.73-0.91) and a specificity of 0.80 (95% CI = 0.65-0.90), the 30-item GDS (GDS-30) had a sensitivity of 0.62 (95% CI = 0.45-0.76) and a specificity 0.81 (95% CI = 0.75-0.85), and the HDRS had a sensitivity of 0.86 (95% CI = 0.63-0.96) and a specificity of 0.84 (95% CI = 0.76-0.90). Summary statistics for all tools across best-reported cutoffs had significant heterogeneity. There are many validated tools for the detection of depression in individuals with dementia. Tools that incorporate a physician interview with patient and collateral histories, the CSDD and HDRS, have higher sensitivities, which would ensure fewer false-negatives. © 2017, Copyright the Authors Journal compilation © 2017, The American Geriatrics Society.
Xu, Li-Qian; Yang, Yun-Mei; Tong, Hong; Xu, Chang-Fu
2018-04-01
Although cardiac troponin is the cornerstone in diagnosis of acute myocardial infarction (AMI), the accuracy is still suboptimal in the early hours after chest pain onset. Due to its small size, heart-type fatty acid-binding protein (H-FABP) has been reported accurate in diagnosis of AMI, however, this remains undetermined. The aim is to investigate the diagnostic performance of H-FABP alone and in conjunction with high-sensitivity troponin (hs-Tn) within 6 hours of symptom onset. Furthermore, accuracy in 0h/3h algorithm was also assessed. Medline and EMBASE databases were searched; sensitivity, specificity and area under ROC curve (AUC) were used as measures of the diagnostic accuracy. We pooled data on bivariate modelling, threshold effect and publication bias was applied for heterogeneity analysis. Twenty-two studies with 6602 populations were included, pooled sensitivity, specificity and AUC of H-FABP were 0.75 (0.68-0.81), 0.81 (0.75-0.86) and 0.85 (0.82-0.88) within 6 hours. Similar sensitivity (0.76, 0.69-0.82), specificity (0.80, 0.71-0.87) and AUC (0.85, 0.82-0.88) of H-FABP were observed in 4185 (63%) patients in 0h/3h algorithm. The additional use of H-FABP improved the sensitivity of hs-Tn alone but worsened its specificity (all p<0.001), and resulted in no improvement of AUC (p>0.99). There was no threshold effect (p=0.18) and publication bias (p=0.31) in this study. H-FABP has modest accuracy for early diagnosis of AMI within 3 and 6 hours of symptom onset. The incremental value of H-FABP seemed much smaller and was of uncertain clinical significance in addition to hs-Tn in patients with suspected AMI. Routine use of H-FABP in early presentation does not seem warranted. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Tsai, Alexander C.
2014-01-01
OBJECTIVES To systematically review the reliability and validity of instruments used to screen for major depressive disorder or assess depression symptom severity among persons with HIV in sub-Saharan Africa. DESIGN Systematic review and meta-analysis. METHODS A systematic evidence search protocol was applied to seven bibliographic databases. Studies examining the reliability and/or validity of depression assessment tools were selected for inclusion if they were based on data collected from HIV-positive adults in any African member state of the United Nations. Random-effects meta-analysis was employed to calculate pooled estimates of depression prevalence. In a subgroup of studies of criterion-related validity, the bivariate random-effects model was used to calculate pooled estimates of sensitivity and specificity. RESULTS Of 1,117 records initially identified, I included 13 studies of 5,373 persons with HIV in 7 sub-Saharan African countries. Reported estimates of Cronbach’s alpha ranged from 0.63–0.95, and analyses of internal structure generally confirmed the existence of a depression-like construct accounting for a substantial portion of variance. The pooled prevalence of probable depression was 29.5% (95% CI, 20.5–39.4), while the pooled prevalence of major depressive disorder was 13.9% (95% CI, 9.7–18.6). The Center for Epidemiologic Studies-Depression scale was the most frequently studied instrument, with a pooled sensitivity of 0.82 (95% CI, 0.73–0.87) for detecting major depressive disorder. CONCLUSIONS Depression screening instruments yielded relatively high false positive rates. Overall, few studies described the reliability and/or validity of depression instruments in sub-Saharan Africa. PMID:24853307
Ye, Feng; Liu, Jun; Ouyang, Han
2015-08-01
The purpose of this meta-analysis was to compare the diagnostic accuracy of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and multidetector-row computed tomography (MDCT) for hepatocellular carcinoma (HCC).Medline, Cochrane, EMBASE, and Google Scholar databases were searched until July 4, 2014, using combinations of the following terms: gadoxetic acid disodium, Gd-EOB-DTPA, multidetector CT, contrast-enhanced computed tomography, and magnetic resonance imaging. Inclusion criteria were as follows: confirmed diagnosis of primary HCC by histopathological examination of a biopsy specimen; comparative study of MRI using Gd-EOB-DTPA and MDCT for diagnosis of HCC; and studies that provided quantitative outcome data. The pooled sensitivity and specificity of the 2 methods were compared, and diagnostic accuracy was assessed with alternative-free response receiver-operating characteristic analysis.Nine studies were included in the meta-analysis, and a total of 1439 lesions were examined. The pooled sensitivity and specificity for 1.5T MRI were 0.95 and 0.96, respectively, for 3.0T MRI were 0.91 and 0.96, respectively, and for MDCT were 0.74 and 0.93, respectively. The pooled diagnostic odds ratio for 1.5T and 3.0T MRI was 242.96, respectively, and that of MDCT was 33.47. To summarize, Gd-EOB-DTPA-enhanced MRI (1.5T and 3.0T) has better diagnostic accuracy for HCC than MDCT.
Chaikriangkrai, Kongkiat; Jhun, Hye Yeon; Shantha, Ghanshyam Palamaner Subash; Abdulhak, Aref Bin; Tandon, Rudhir; Alqasrawi, Musab; Klappa, Anthony; Pancholy, Samir; Deshmukh, Abhishek; Bhama, Jay; Sigurdsson, Gardar
2018-07-01
In aortic stenosis patients referred for surgical and transcatheter aortic valve replacement (AVR), the evidence of diagnostic accuracy of coronary computed tomography angiography (CCTA) has been limited. The objective of this study was to investigate the diagnostic accuracy of CCTA for significant coronary artery disease (CAD) in patients referred for AVR using invasive coronary angiography (ICA) as the gold standard. We searched databases for all diagnostic studies of CCTA in patients referred for AVR, which reported diagnostic testing characteristics on patient-based analysis required to pool summary sensitivity, specificity, positive-likelihood ratio, and negative-likelihood ratio. Significant CAD in both CCTA and ICA was defined by >50% stenosis in any coronary artery, coronary stent, or bypass graft. Thirteen studies evaluated 1498 patients (mean age, 74 y; 47% men; 76% transcatheter AVR). The pooled prevalence of significant stenosis determined by ICA was 43%. Hierarchical summary receiver-operating characteristic analysis demonstrated a summary area under curve of 0.96. The pooled sensitivity, specificity, and positive-likelihood and negative-likelihood ratios of CCTA in identifying significant stenosis determined by ICA were 95%, 79%, 4.48, and 0.06, respectively. In subgroup analysis, the diagnostic profiles of CCTA were comparable between surgical and transcatheter AVR. Despite the higher prevalence of significant CAD in patients with aortic stenosis than with other valvular heart diseases, our meta-analysis has shown that CCTA has a suitable diagnostic accuracy profile as a gatekeeper test for ICA. Our study illustrates a need for further study of the potential role of CCTA in preoperative planning for AVR.
Huo, Zhen-Yu; Peng, Li
2018-06-25
Tuberculous pleurisy (TP) presents a diagnostic problem due to the limitations of traditional diagnostic methods. Different studies with the Xpert MTB/RIF assay have drawn variable conclusions about its values in TP diagnosis. We conducted a meta-analysis to assess whether the Xpert MTB/RIF assay is appropriate for the diagnosis of TP using pleural fluid samples. A systematic search of four literature databases in English and Chinese language was performed to identify studies involving the use of Xpert MTB/RIF in patients with TP confirmed by plural biopsy and/or mycobacterial culture. Pooled sensitivity, specificity and accordance proportion were calculated, and the forest plots were generated to assess the accuracy of Xpert MTB/RIF for TP diagnosis. We identified 23 studies meeting our inclusion criteria. The pooled sensitivity and specificity of Xpert MTB/RIF were 30% (95% CI: 21-42%, I 2 = 87.93%) and 99% (95% CI: 97-100%, I 2 = 96.20%), respectively, and the area under the SROC curve (AUC) of Xpert MTB/RIF was 0.86 (95% CI: 0.83-0.89). Compared with drug susceptibility testing (DST), the pooled accordance rate of Xpert MTB/RIF in detecting rifampicin-susceptible cases and rifampicin-resistant cases was 99% (95% CI: 95-104%, I 2 = 8.7%) and 94% (95% CI: 86-102%), respectively. Our analysis suggests that the Xpert MTB/RIF assay is of limited value as a screening test for TP but has a high potential for confirming TP diagnosis and differentiating TP from non-TB diseases using pleural fluid samples.
Al-Qurayshi, Zaid; Deniwar, Ahmed; Thethi, Tina; Mallik, Tilak; Srivastav, Sudesh; Murad, Fadi; Bhatia, Parisha; Moroz, Krzysztof; Sholl, Andrew B; Kandil, Emad
2017-04-01
It is crucial for clinicians to know the malignancy prevalence within each indeterminate cytologic category to estimate the performance of the gene expression classifier (GEC). To examine the variability in the performance of the GEC. This retrospective cohort study of patients with Bethesda category III and IV thyroid nodules used single-institution data from January 1, 2013, through February 29, 2016. Expected negative predictive value (NPV) was calculated by adopting published sensitivity and specificity. Observed NPV was calculated based on the true-negative rate. Outcomes were compared with pooled data from 11 studies published January 1, 2010, to January 31, 2016. A total of 145 patients with 154 thyroid nodules were included in the study (mean [SD] age, 56.0 [16.2] years; 106 females [73.1%]). Malignancy prevalence was 45%. On the basis of this prevalence, the expected NPV is 85% and the observed NPV is 69%. If the prevalence is assumed to be 25%, the expected NPV would be 94%, whereas the observed NPV would be 85%. Pooled data analysis of 11 studies comprising 1303 participants revealed a malignancy prevalence of 31% (95% CI, 29%-34%) and a pooled NPV of 92% (95% CI, 87%-96%). In this study, variability in the performance of the GEC was not solely a function of malignancy prevalence and may have been attributable to intrinsic variability of the test sensitivity and specificity. The utility of the GEC in practice is elusive because of this variability. A better definition of the GEC's intrinsic properties is needed.
Li, Yan-Wei; Zhou, Le-Shan; Li, Xing
2017-03-15
Fever is the most common complaint in the pediatric and emergency departments. Caregivers prefer to detect fever in their children by tactile assessment. To summarize the evidence on the accuracy of caregivers' tactile assessment for detecting fever in children. We performed a literature search of Cochrane Library, PubMed, Web of Knowledge, EMBASE (ovid), EBSCO and Google Scholar, without restriction of publication date, to identify English articles assessing caregivers' ability of detecting fever in children by tactile assessment. Quality assessment was based on the 2011 Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria. Pooled estimates of sensitivity and specificity were calculated with use of bivariate model and summary receiver operation characteristics plots for meta-analysis. 11 articles were included in our analysis. The summary estimates for tactile assessment as a diagnostic tool revealed a sensitivity of 87.5% (95% CI 79.3% to 92.8%) and specificity of 54.6% (95% CI 38.5% to 69.9%). The pooled positive likelihood ratio was 1.93 (95% CI 1.39 to 2.67) and negative likelihood ratio was 0.23 (95% CI 0.15 to 0.36). Area under curve was 0.82 (95% CI 0.7 to 0.85). The pooled diagnostic odds ratio was 8.46 (95% CI 4.54 to 15.76). Tactile assessment of fever in children by palpation has moderate diagnostic value. Caregivers' assessment as "no fever" by touch is quite accurate in ruling out fever, while assessment as "fever" can be considered but needs confirmation.
Accuracy of magnetic resonance venography in diagnosing cerebral venous sinus thrombosis.
Gao, Liansheng; Xu, Weilin; Li, Tao; Yu, Xiaobo; Cao, Shenglong; Xu, Hangzhe; Yan, Feng; Chen, Gao
2018-05-17
The non-specific clinical manifestations and lack of effective diagnostic techniques have made cerebral venous sinus thrombosis (CVST) difficult to recognize and easy to misdiagnose. Several studies have suggested that different types of magnetic resonance venography (MRV) have advantages in diagnosing CVST. We conducted this meta-analysis to assess the accuracy of MRV in identifying CVST. We searched the Embase, PubMed, and Chinese Biomedical (CBM) databases comprehensively to retrieve eligible articles up to Mar 31, 2018. The methodological quality of each article was evaluated individually. The summary diagnostic accuracy of MRV for CVST was obtained from pooled analysis with random-effects models. Sensitivity analysis, subgroup analysis, and meta-regression were used to explore the sources of heterogeneity. A trim and fill analysis was conducted to correct the funnel plot asymmetry. The meta-analysis synthesized 12 articles containing 27 cohorts with a total of 1933 cases. The pooled sensitivity and specificity were 0.86 (95% CI: 0.83, 0.89) and 0.94 (95% CI: 0.93, 0.95), respectively. The pooled diagnostic odds ratio (DOR) was 75.24 (95% CI: 38.33, 147.72). The area under the curve (AUC) was 0.9472 (95% CI: 0.9229, 0.9715). Subgroup analysis and meta-regression analysis revealed the technical types of MRV and the methods of counting cases contributing to the heterogeneity. The trim and fill method confirmed that publication bias has little effect on our results. MRV has excellent diagnostic performance and is accurate in confirming CVST. Copyright © 2018 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernard, Alfred, E-mail: Alfred.bernard@uclouvain.be; Nickmilder, Marc; Dumont, Xavier
It has been suggested that allergic diseases might be epithelial disorders driven by various environmental stressors but the epidemiological evidence supporting this concept is limited. In a cross-sectional study of 835 school adolescents (365 boys; mean age, 15.5 yr), we measured the serum concentrations of Club cell protein (CC16), surfactant-associated protein D (SP-D) and of total and aeroallergen-specific IgE. We used the serum CC16/SP-D concentration ratio as an index integrating changes in the permeability (SP-D) and secretory function (CC16) of the airway epithelium. In both sexes, early swimming in chlorinated pools emerged as the most consistent and strongest predictor ofmore » low CC16 and CC16/SP-D ratio in serum. Among girls, a low CC16/SP-D ratio was associated with increased odds (lowest vs. highest tertile) for pet sensitization (OR 2.97, 95% CI 1.19–8.22) and for hay fever in subjects sensitized to pollen (OR 4.12, 95% CI 1.28–14.4). Among boys, a low CC16/SP-D ratio was associated with increased odds for house-dust mite (HDM) sensitization (OR 2.01, 95% CI 1.11–3.73), for allergic rhinitis in subjects sensitized to HDM (OR 3.52, 95% CI 1.22–11.1) and for asthma in subjects sensitized to any aeroallergen (OR 3.38, 95% CI 1.17–11.0), HDM (OR 5.20, 95% CI 1.40–24.2) or pollen (OR 5.82, 95% CI 1.51–27.4). Odds for allergic sensitization or rhinitis also increased with increasing SP-D or decreasing CC16 in serum. Our findings support the hypothesis linking the development of allergic diseases to epithelial barrier defects due to host factors or environmental stressors such as early swimming in chlorinated pools. - Highlights: • We conducted a cross-sectional study of 835 school adolescents. • The airway epithelium integrity was evaluated by measuring serum pneumoproteins. • The risk of allergic diseases was associated with a defective airway epithelium. • Childhood swimming in chlorinated pools can cause persistent epithelial alterations.« less
Jensen, Kristina Kvist; Grønhøj, Christian; Jensen, David H; von Buchwald, Christian
2018-05-15
The incidence of human papillomavirus-induced (HPV+) head and neck squamous cell carcinoma (HNSCC) i.e. especially oropharyngeal cancers (OPSCC) is increasing and a significant proportion of patients encounter disease progression. A simple and sensitive test to identify patients with progression is an unmet need. To systematically review the literature and carry out a meta-analysis of studies, investigated circulating HPV-DNA as a biomarker for disease progression in patients with HNSCC. A systematic review and meta-analysis. PubMed, Embase and the Cochrane Library were systematically searched for articles published in English from January 1980 to November 2017. Search terms used were related to HPV, cancer sites, blood-based biomarkers and terms for specific use settings. Articles reviewed and selected by authors and data on study design, demographic variables, location, HPV status, number of pre treatment blood tests, number of post treatment blood tests, blood HPV status and number of recurrences and length of follow-up was extracted. A meta-analysis of HPV-DNA as a diagnostic test for recurrence by means of a hierarchical summary receiver operating curve (HSROC) model was performed. We identified five studies (n=600 subjects) examining circulating HPV-DNA in patients with HNSCC. In these five studies (n=411) patients had both pre and post treatment blood samples. The pooled sensitivity, in detecting a recurrence was estimated to be 54% (95% CI: 32%-74%), while the pooled specificity was 98% (95% CI: 93-99.4%). The pooled false-positive rate is 2% (95% CI: 0.6%-7%). The area under the curve (AUC) of the summary HSROC was 0.93. Positive predictive value was estimated to 93% and the negative predictive value to 94%. Plasma HPV-DNA is a promising tool for surveillance in patients with HPV-related HNSCC i.e. OPSCC and has a high specificity. By recent technical advances and by increasing follow-up blood samples the sensitivity could likely be improved. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Wu, Hon-Yen; Peng, Yu-Sen; Chiang, Chih-Kang; Huang, Jenq-Wen; Hung, Kuan-Yu; Wu, Kwan-Dun; Tu, Yu-Kang; Chien, Kuo-Liong
2014-07-01
A random urine sample measuring the albumin concentration (UAC) without simultaneously measuring the urinary creatinine is less expensive than measuring the ratio of albumin to creatinine (ACR), but comparisons of their diagnostic performance for microalbuminuria screening among patients with diabetes mellitus (DM) have not been undertaken in previous meta-analyses. To compare the diagnostic performance of the UAC vs the ACR in random urine samples for microalbuminuria screening among patients with DM. Electronic literature searches of PubMed, MEDLINE, and Scopus for English-language publications from the earliest available date of indexing through July 31, 2012. Clinical studies assessing the UAC or the ACR of random urine samples in detecting the presence of microalbuminuria among patients with DM using a urinary albumin excretion rate of 30 to 300 mg/d in 24-hour timed urine collections as the criterion standard. Bivariate random-effects models for analysis and pooling of the diagnostic performance measures across studies, as well as comparisons between different screening tests. The primary end point was the diagnostic performance measures of the UAC or the ACR in random urine samples, as well as comparisons between them. We identified 14 studies, with a total of 2078 patients; 9 studies reported on the UAC, and 12 studies reported on the ACR. Meta-analysis showed pooled sensitivities of 0.85 and 0.87 for the UAC and the ACR, respectively, and pooled specificities of 0.88 and 0.88, respectively. No differences in sensitivity (P = .70), specificity (P = .63), or diagnostic odds ratios (P = .59) between the UAC and the ACR were found. The time point of urine collection did not affect the diagnostic performance of either test. The UAC and the ACR yielded high sensitivity and specificity for the detection of microalbuminuria. Because the diagnostic performance of the UAC is comparable to that of the ACR, our findings indicate that the UAC of random urine samples may become the screening tool of choice for the population with DM, considering the rising incidence of DM and the constrained health care resources in many countries.
Antibody Desensitization Therapy in Highly Sensitized Lung Transplant Candidates
Snyder, L. D.; Gray, A. L.; Reynolds, J. M.; Arepally, G. M.; Bedoya, A.; Hartwig, M. G.; Davis, R. D.; Lopes, K. E.; Wegner, W. E.; Chen, D. F.; Palmer, S. M.
2015-01-01
As HLAs antibody detection technology has evolved, there is now detailed HLA antibody information available on prospective transplant recipients. Determining single antigen antibody specificity allows for a calculated panel reactive antibodies (cPRA) value, providing an estimate of the effective donor pool. For broadly sensitized lung transplant candidates (cPRA ≥ 80%), our center adopted a pretransplant multimodal desensitization protocol in an effort to decrease the cPRA and expand the donor pool. This desensitization protocol included plasmapheresis, solumedrol, bortezomib and rituximab given in combination over 19 days followed by intravenous immunoglobulin. Eight of 18 candidates completed therapy with the primary reasons for early discontinuation being transplant (by avoiding unacceptable antigens) or thrombocytopenia. In a mixed-model analysis, there were no significant changes in PRA or cPRA changes over time with the protocol. A sub-analysis of the median fluorescence intensity (MFI) change indicated a small decline that was significant in antibodies with MFI 5000–10 000. Nine of 18 candidates subsequently had a transplant. Posttransplant survival in these nine recipients was comparable to other pretransplant-sensitized recipients who did not receive therapy. In summary, an aggressive multi-modal desensitization protocol does not significantly reduce pretransplant HLA antibodies in a broadly sensitized lung transplant candidate cohort. PMID:24666831
Ikeda, M; Kurokawa, K; Maruyama, Y
1994-06-01
Ca(2+)-mediated Ca2+ spikes were analysed in fura-2-loaded megakaryocytes. Direct Ca2+ loading using whole-cell dialysis induced an all-or-none Ca2+ spike on top of a tonic increase in cellular Ca2+ concentration ([Ca2+]i) with a latency of 3-7 s. The latency decreased with increasingly higher concentrations of Ca2+ in the dialysing solution. Spike size and its initiation did not correlate with the tonic level of [Ca2+]i. Thapsigargin completely abolished the Ca(2+)-induced spike initiation, suggesting that Ca2+ spikes originate from thapsigargin-sensitive Ca2+ pools. An inhibitor of phosphatidylinositide-specific phospholipase C (PLC), 2-nitro-4-carboxyphenyl-N,N-diphenyl-carbamate prolonged the latency without changes of spike size in most cases (6/9 cells), but abolished the spike initiation in the other cells (3/9). The results suggest that an increase in [Ca2+]i charges up the inositol-1,4,5-trisphosphate-(InsP3)- and thapsigargin-sensitive Ca2+ pools which progressively sensitize to low or slightly elevated levels of InsP3 by the action of Ca(2+)-dependent PLC until a critical Ca2+ content is reached, and then the Ca2+ spike is triggered. Thus, the limiting step of Ca2+ spike triggering is the initial filling process and the level of InsP3 in megakaryocytes.
Ibraheem, Kareem; Toraih, Eman A; Haddad, Antoine B; Farag, Mahmoud; Randolph, Gregory W; Kandil, Emad
2018-05-14
Minimally invasive parathyroidectomy requires accurate preoperative localization techniques. There is considerable controversy about the effectiveness of selective parathyroid venous sampling (sPVS) in primary hyperparathyroidism (PHPT) patients. The aim of this meta-analysis is to examine the diagnostic accuracy of sPVS as a preoperative localization modality in PHPT. Studies evaluating the diagnostic accuracy of sPVS for PHPT were electronically searched in the PubMed, EMBASE, Web of Science, and Cochrane Controlled Trials Register databases. Two independent authors reviewed the studies, and revised quality assessment of diagnostic accuracy study tool was used for the quality assessment. Study heterogeneity and pooled estimates were calculated. Two hundred and two unique studies were identified. Of those, 12 studies were included in the meta-analysis. Pooled sensitivity, specificity, and positive likelihood ratio (PLR) of sPVS were 74%, 41%, and 1.55, respectively. The area-under-the-receiver operating characteristic curve was 0.684, indicating an average discriminatory ability of sPVS. On comparison between sPVS and noninvasive imaging modalities, sensitivity, PLR, and positive posttest probability were significantly higher in sPVS compared to noninvasive imaging modalities. Interestingly, super-selective venous sampling had the highest sensitivity, accuracy, and positive posttest probability compared to other parathyroid venous sampling techniques. This is the first meta-analysis to examine the accuracy of sPVS in PHPT. sPVS had higher pooled sensitivity when compared to noninvasive modalities in revision parathyroid surgery. However, the invasiveness of this technique does not favor its routine use for preoperative localization. Super-selective venous sampling was the most accurate among all other parathyroid venous sampling techniques. Laryngoscope, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.
Yan, Shi; Jin, YinZhe; Oh, YongSeok; Choi, YoungJun
2016-06-01
The aim of this study was to assess the effect of exercise on depression in university students. A systematic literature search was conducted in PubMed, EMBASE and the Cochrane library from their inception through December 10, 2014 to identify relevant articles. The heterogeneity across studies was examined by Cochran's Q statistic and the I2 statistic. Standardized mean difference (SMD) and 95% confidence interval (CI) were pooled to evaluate the effect of exercise on depression. Then, sensitivity and subgroup analyses were performed. In addition, publication bias was assessed by drawing a funnel plot. A total of 352 participants (154 cases and 182 controls) from eight included trials were included. Our pooled result showed a significant alleviative depression after exercise (SMD=-0.50, 95% CI: -0.97 to -0.03, P=0.04) with significant heterogeneity (P=0.003, I2=67%). Sensitivity analyses showed that the pooled result may be unstable. Subgroup analysis indicated that sample size may be a source of heterogeneity. Moreover, no publication bias was observed in this study. Exercise may be an effective therapy for treating depression in university students. However, further clinical studies with strict design and large samples focused on this specific population should be warranted in the future.
Radiocarbon Evidence That Millennial and Fast-Cycling Soil Carbon are Equally Sensitive to Warming
NASA Astrophysics Data System (ADS)
Vaughn, L. S.; Torn, M. S.; Porras, R. C.
2017-12-01
Within the century, the Arctic is expected to shift from a sink to a source of atmospheric CO2 due to climate-induced increases in soil carbon mineralization. The magnitude of this effect remains uncertain, due in large part to unknown temperature sensitivities of organic matter decomposition. In particular, the distribution of temperature sensitivities across soil carbon pools remains unknown. New experimental approaches are needed, because studies that fit multi-pool models to CO2 flux measurements may be sensitive to model assumptions, statistical effects, and non-steady-state changes in substrate availability or microbial activity. In this study, we developed a new methodology using natural abundance radiocarbon to evaluate temperature sensitivities across soil carbon pools. In two incubation experiments with soils from Barrow, AK, we (1) evaluated soil carbon age and decomposability, (2) disentangled the effects of temperature and substrate depletion on carbon mineralization, and (3) compared the temperature sensitivities of fast- and slow-cycling soil carbon pools. From a long-term incubation, both respired CO2 and the remaining soil organic matter were highly depleted in radiocarbon. At 20 cm depth, median Δ14C values were -167‰ in respired CO2 and -377‰ in soil organic matter, corresponding to turnover times of 1800 and 4800 years, respectively. Such negative Δ14C values indicate both storage and decomposition of old, stabilized carbon, while radiocarbon differences between the mineralized and non-mineralized fractions suggest that decomposability varies along a turnover time gradient. Applying a new analytical method combining CO2 flux and Δ14C, we found that fast- and slow-cycling carbon pools were equally sensitive to temperature, with a Q10 of 2 irrespective of turnover time. We conclude that in these Arctic soils, ancient soil carbon is vulnerable to warming under thawed, aerobic conditions. In contrast to many previous studies, we found no difference in temperature sensitivity of decomposition between fast- and slow-cycling pools. These findings suggest that in these soils, carbon stabilization mechanisms other than chemical recalcitrance mediate temperature sensitivities, and even old SOC will be readily decomposable as climate warms.
Yin, Xinxin; Zheng, Wen; Ma, Jingjing; Hao, Panpan
2016-01-01
Background Both coronary computed tomography angiography (CCTA) and exercise electrocardiography (ExECG) are non-invasive testing methods for the evaluation of coronary artery disease (CAD). However, there was controversy on the diagnostic performance of these methods due to the limited data in each single study. Therefore, we performed a meta-analysis to address these issues. Methods We searched PubMed and Embase databases up to May 22, 2015. Two authors identified eligible studies, extracted data and accessed quality. Pooled estimation of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), summary receiver-operating characteristic curve (SROC) and the area under curve (AUC) of CCTA and ExECG for the diagnosis of CAD were calculated using Stata, Meta-Disc and Review Manager statistical software. Results Seven articles were included. Pooled sensitivity of CCTA and ExECG were 0.98 [95% confidence intervals (CIs): 0.95–0.99] and 0.66 (95% CIs: 0.59–0.72); pooled specificity of CCTA and ExECG were 0.84 (95% CIs: 0.81–0.87) and 0.75 (95% CIs: 0.71–0.79); pooled DOR of CCTA and ExECG were 110.24 (95% CIs: 35.07–346.55) and 6.28 (95% CIs: 2.06–19.13); and AUC of CCTA and ExECG were 0.9950±0.0046 and 0.7727±0.0638, respectively. There is no heterogeneity caused by threshold effect in CCTA or ExECG analysis. The Deeks’ test showed no potential publication bias (P=0.17). Conclusions CCTA has better diagnostic performance than ExECG in the evaluation of CAD, which can provide a better solution for the clinical problem of the diagnosis for CAD. PMID:27499958
Faes, L; Bodmer, N S; Bachmann, L M; Thiel, M A; Schmid, M K
2014-07-01
To clarify the screening potential of the Amsler grid and preferential hyperacuity perimetry (PHP) in detecting or ruling out wet age-related macular degeneration (AMD). Medline, Scopus and Web of Science (by citation of reference) were searched. Checking of reference lists of review articles and of included articles complemented electronic searches. Papers were selected, assessed, and extracted in duplicate. Systematic review and meta-analysis. Twelve included studies enrolled 903 patients and allowed constructing 27 two-by-two tables. Twelve tables reported on the Amsler grid and its modifications, twelve tables reported on the PHP, one table assessed the MCPT and two tables assessed the M-charts. All but two studies had a case-control design. The pooled sensitivity of studies assessing the Amsler grid was 0.78 (95% confidence intervals; 0.64-0.87), and the pooled specificity was 0.97 (95% confidence intervals; 0.91-0.99). The corresponding positive and negative likelihood ratios were 23.1 (95% confidence intervals; 8.4-64.0) and 0.23 (95% confidence intervals; 0.14-0.39), respectively. The pooled sensitivity of studies assessing the PHP was 0.85 (95% confidence intervals; 0.80-0.89), and specificity was 0.87 (95% confidence intervals; 0.82-0.91). The corresponding positive and negative likelihood ratios were 6.7 (95% confidence intervals; 4.6-9.8) and 0.17 (95% confidence intervals; 0.13-0.23). No pooling was possible for MCPT and M-charts. Results from small preliminary studies show promising test performance characteristics both for the Amsler grid and PHP to rule out wet AMD in the screening setting. To what extent these findings can be transferred to a real clinic practice still needs to be established.
Muthu, Valliappan; Sehgal, Inderpaul Singh; Dhooria, Sahajal; Aggarwal, Ashutosh N; Agarwal, Ritesh
2018-06-21
The role of recombinant A.fumigatus (rAsp) antigens in the diagnosis of allergic bronchopulmonary aspergillosis (ABPA) has not been systematically evaluated. Herein, we evaluate the utility of recombinant A.fumigatus (rAsp) antigens in diagnosing ABPA. We systematically reviewed the PubMed, EmBase, and Scopus databases for studies evaluating rAsp antigens in ABPA. The QUADAS-2 tool and the GRADE approach were used to assess the risk of bias and the quality of evidence, respectively. The diagnostic performance of IgE or skin test against rAsp f1, f2, f3, f4, f6, and their combination was evaluated separately for ABPA complicating asthma or cystic fibrosis (CF), using an HSROC model. The reference standard for diagnosing ABPA was the composite (clinical, radiological, immunological) criteria. Our search yielded 26 studies (n=1,694) and 17 studies (n=1,131) for inclusion in the systematic review and meta-analysis, respectively. In asthmatics, the pooled sensitivity for diagnosing ABPA was best for IgE against a combination of rAsp f1 or f3 (96.7%; 95% confidence interval [CI], 87.6-99.2). The pooled specificity for diagnosing ABPA was highest (99.2%; 95% CI, 88.2-99.9) for IgE against a combination of f4 or f6. In CF patients, the pooled sensitivity of rAsp f1 or f3 was 93.3% (95% CI, 55.2-99.9) while the pooled specificity of rAsp f4 or f6 was 93.9% (95% CI, 68.8-99.9). The quality of evidence was low as per the GRADE approach. A combination of IgE against rAsp antigens (f1, f2, f3, f4, f6) are likely to be helpful in the diagnosis of ABPA. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Yoshikawa, Hiroyuki
2016-01-01
Objective We conducted a pooled analysis of published studies to compare the performance of human papillomavirus (HPV) testing and cytology in detecting residual or recurrent diseases after treatment for cervical intraepithelial neoplasia grade 2 or 3 (CIN 2/3). Methods Source articles presenting data on posttreatment HPV testing were identified from the National Library of Medicine (PubMed) database. We included 5,319 cases from 33 articles published between 1996 and 2013. Results The pooled sensitivity of high-risk HPV testing (0.92; 95% confidence interval [CI], 0.90 to 0.94) for detecting posttreatment CIN 2 or worse (CIN 2+) was much higher than that of cytology (0.76; 95% CI, 0.71 to 0.80). Co-testing of HPV testing and cytology maximized the sensitivity (0.93; 95% CI, 0.87 to 0.96), while HPV genotyping (detection of the same genotype between pre- and posttreatments) did not improve the sensitivity (0.89; 95% CI, 0.82 to 0.94) compared with high-risk HPV testing alone. The specificity of high-risk HPV testing (0.83; 95% CI, 0.82 to 0.84) was similar to that of cytology (0.85; 95% CI, 0.84 to 0.87) and HPV genotyping (0.83; 95% CI, 0.81 to 0.85), while co-testing had reduced specificity (0.76; 95% CI, 0.75 to 0.78). For women with positive surgical margins, high-risk HPV testing provided remarkable risk discrimination between test-positives and test-negatives (absolute risk of residual CIN 2+ 74.4% [95% CI, 64.0 to 82.6] vs. 0.8% [95% CI, 0.15 to 4.6]; p<0.001). Conclusion Our findings recommend the addition of high-risk HPV testing, either alone or in conjunction with cytology, to posttreatment surveillance strategies. HPV testing can identify populations at greatest risk of posttreatment CIN 2+ lesions, especially among women with positive section margins. PMID:26463429
Krajden, Mel; Cook, Darrel; Mak, Annie; Chu, Ken; Chahil, Navdeep; Steinberg, Malcolm; Rekart, Michael; Gilbert, Mark
2014-09-01
We compared a 3rd generation (gen) and two 4th gen HIV enzyme immunoassays (EIA) to pooled nucleic acid testing (PNAT) for the identification of pre- and early seroconversion acute HIV infection (AHI). 9550 specimens from males >18 year from clinics attended by men who have sex with men were tested by Siemens ADVIA Centaur(®) HIV 1/O/2 (3rd gen) and HIV Combo (4th gen), as well as by Abbott ARCHITECT(®) HIV Ag/Ab Combo (4th gen). Third gen non-reactive specimens were also tested by Roche COBAS(®) Ampliprep/COBAS® TaqMan HIV-1 Test v.2 in pools of 24 samples. Sensitivity and specificity of the three EIAs for AHI detection were compared. 7348 persons contributed 9435 specimens and had no evidence of HIV infection, 79 (94 specimens) had established HIV infection, 6 (9 specimens) had pre-seroconversion AHI and 9 (12 specimens) had early seroconversion AHI. Pre-seroconversion AHI cases were not detected by 3rd gen EIA, whereas 2/6 (33.3%) were detected by Siemens 4th gen, 4/6 (66.7%) by Abbott 4th gen and 6/6 (100%) by PNAT. All three EIAs and PNAT detected all individuals with early seroconversion AHI. Overall sensitivity/specificity for the EIAs relative to WB or NAT resolved infection status was 93.6%/99.9% for Siemens 3rd gen, 95.7%/99.7% for Siemens 4th gen and 97.9%/99.2% for Abbott 4th gen. While both 4th gen EIAs demonstrated improved sensitivity for AHI compared to 3rd gen EIA, PNAT identified more AHI cases than either 4th gen assay. PNAT is likely to remain a useful strategy to identify AHI in high-risk populations. Copyright © 2014 Elsevier B.V. All rights reserved.
Vernal pool fairy shrimp, Branchinecta lynchi, (Branchiopoda; Anostraca) and other fairy shrimp species have been listed as threatened or endangered under the US Endangered Species Act. Because few data exist about the sensitivity of Branchinecta spp. to toxic effects of contamin...
Fernando, Shannon M; Tran, Alexandre; Cheng, Wei; Rochwerg, Bram; Kyeremanteng, Kwadwo; Seely, Andrew J E; Inaba, Kenji; Perry, Jeffrey J
2018-04-18
We sought to summarize accuracy of physical examination, imaging, and Laboratory Risk Indicator for Necrotizing Fasciitis (LRINEC) score in diagnosis of necrotizing soft tissue infection (NSTI) in adults with a soft tissue infection clinically concerning for NSTI. NSTI is a life-threatening diagnosis. Delay to diagnosis and surgical management is associated with increased mortality. We searched 6 databases from inception through November 2017. We included English-language studies reporting diagnostic accuracy of testing or LRINEC Score. Outcome was NSTI confirmed by surgery or histopathology. Two reviewers screened all citations and extracted data independently. Summary measures were obtained from the Hierarchical Summary Receiver Operating Characteristic model. From 2,290 citations, we included 23 studies (n = 5982). Of physical examination signs, pooled sensitivity and specificity for fever was 46.0% and 77.0% respectively, for hemorrhagic bullae 25.2% and 95.8%, and for hypotension 21.0% and 97.7%. Computed tomography (CT) had sensitivity of 88.5% and specificity of 93.3%, while plain radiography had sensitivity of 48.9% and specificity of 94.0%. Finally, LRINEC ≥ 6 had sensitivity of 68.2% and specificity of 84.8%, while LRINEC ≥ 8 had sensitivity of 40.8% and specificity of 94.9%. Absence of any 1 physical examination feature (eg, fever or hypotension) is not sufficient to rule-out NSTI. CT is superior to plain radiography. LRINEC had poor sensitivity, and should not be used to rule-out NSTI. Given the poor sensitivity of these tests, a high clinical suspicion warrants early surgical consultation for definitive diagnosis and management.
Lateral flow urine lipoarabinomannan assay for detecting active tuberculosis in HIV-positive adults.
Shah, Maunank; Hanrahan, Colleen; Wang, Zhuo Yu; Dendukuri, Nandini; Lawn, Stephen D; Denkinger, Claudia M; Steingart, Karen R
2016-05-10
Rapid detection of tuberculosis (TB) among people living with human immunodeficiency virus (HIV) is a global health priority. HIV-associated TB may have different clinical presentations and is challenging to diagnose. Conventional sputum tests have reduced sensitivity in HIV-positive individuals, who have higher rates of extrapulmonary TB compared with HIV-negative individuals. The lateral flow urine lipoarabinomannan assay (LF-LAM) is a new, commercially available point-of-care test that detects lipoarabinomannan (LAM), a lipopolysaccharide present in mycobacterial cell walls, in people with active TB disease. To assess the accuracy of LF-LAM for the diagnosis of active TB disease in HIV-positive adults who have signs and symptoms suggestive of TB (TB diagnosis).To assess the accuracy of LF-LAM as a screening test for active TB disease in HIV-positive adults irrespective of signs and symptoms suggestive of TB (TB screening). We searched the following databases without language restriction on 5 February 2015: the Cochrane Infectious Diseases Group Specialized Register; MEDLINE (PubMed,1966); EMBASE (OVID, from 1980); Science Citation Index Expanded (SCI-EXPANDED, from 1900), Conference Proceedings Citation Index-Science (CPCI-S, from 1900), and BIOSIS Previews (from 1926) (all three using the Web of Science platform; MEDION; LILACS (BIREME, from 1982); SCOPUS (from 1995); the metaRegister of Controlled Trials (mRCT); the search portal of the World Health Organization International Clinical Trials Registry Platform (WHO ICTRP); and ProQuest Dissertations & Theses A&l (from 1861). Eligible study types included randomized controlled trials, cross-sectional studies, and cohort studies that determined LF-LAM accuracy for TB against a microbiological reference standard (culture or nucleic acid amplification test from any body site). A higher quality reference standard was one in which two or more specimen types were evaluated for TB, and a lower quality reference standard was one in which only one specimen type was evaluated for TB. Participants were HIV-positive people aged 15 years and older. Two review authors independently extracted data from each included study using a standardized form. We appraised the quality of studies using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. We evaluated the test at two different cut-offs: (grade 1 or 2, based on the reference card scale of five intensity bands). Most analyses used grade 2, the manufacturer's currently recommended cut-off for positivity. We carried out meta-analyses to estimate pooled sensitivity and specificity using a bivariate random-effects model and estimated the models using a Bayesian approach. We determined accuracy of LF-LAM combined with sputum microscopy or Xpert® MTB/RIF. In addition, we explored the influence of CD4 count on the accuracy estimates. We assessed the quality of the evidence using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. We included 12 studies: six studies evaluated LF-LAM for TB diagnosis and six studies evaluated the test for TB screening. All studies were cross-sectional or cohort studies. Studies for TB diagnosis were largely conducted among inpatients (median CD4 range 71 to 210 cells per µL) and studies for TB screening were largely conducted among outpatients (median CD4 range 127 to 437 cells per µL). All studies were conducted in low- or middle-income countries. Only two studies for TB diagnosis (33%) and one study for TB screening (17%) used a higher quality reference standard.LF-LAM for TB diagnosis (grade 2 cut-off): meta-analyses showed median pooled sensitivity and specificity (95% credible interval (CrI)) of 45% (29% to 63%) and 92% (80% to 97%), (five studies, 2313 participants, 35% with TB, low quality evidence). The pooled sensitivity of a combination of LF-LAM and sputum microscopy (either test positive) was 59% (47% to 70%), which represented a 19% (4% to 36%) increase over sputum microscopy alone, while the pooled specificity was 92% (73% to 97%), which represented a 6% (1% to 24%) decrease from sputum microscopy alone (four studies, 1876 participants, 38% with TB). The pooled sensitivity of a combination of LF-LAM and sputum Xpert® MTB/RIF (either test positive) was 75% (61% to 87%) and represented a 13% (1% to 37%) increase over Xpert® MTB/RIF alone. The pooled specificity was 93% (81% to 97%) and represented a 4% (1% to 16%) decrease from Xpert® MTB/RIF alone (three studies, 909 participants, 36% with TB). Pooled sensitivity and specificity of LF-LAM were 56% (41% to 70%) and 90% (81% to 95%) in participants with a CD4 count of less than or equal to 100 cells per µL (five studies, 859 participants, 47% with TB) versus 26% (16% to 46%) and 92% (78% to 97%) in participants with a CD4 count greater than 100 cells per µL (five studies, 1410 participants, 30% with TB).LF-LAM for TB screening (grade 2 cut-off): for individual studies, sensitivity estimates (95% CrI) were 44% (30% to 58%), 28% (16% to 42%), and 0% (0% to 71%) and corresponding specificity estimates were 95% (92% to 97%), 94% (90% to 97%), and 95% (92% to 97%) (three studies, 1055 participants, 11% with TB, very low quality evidence). There were limited data for additional analyses.The main limitations of the review were the use of a lower quality reference standard in most included studies, and the small number of studies and participants included in the analyses. The results should, therefore, be interpreted with caution. We found that LF-LAM has low sensitivity to detect TB in adults living with HIV whether the test is used for diagnosis or screening. For TB diagnosis, the combination of LF-LAM with sputum microscopy suggests an increase in sensitivity for TB compared to either test alone, but with a decrease in specificity. In HIV-positive individuals with low CD4 counts who are seriously ill, LF-LAM may help with the diagnosis of TB.
Effective classification of the prevalence of Schistosoma mansoni.
Mitchell, Shira A; Pagano, Marcello
2012-12-01
To present an effective classification method based on the prevalence of Schistosoma mansoni in the community. We created decision rules (defined by cut-offs for number of positive slides), which account for imperfect sensitivity, both with a simple adjustment of fixed sensitivity and with a more complex adjustment of changing sensitivity with prevalence. To reduce screening costs while maintaining accuracy, we propose a pooled classification method. To estimate sensitivity, we use the De Vlas model for worm and egg distributions. We compare the proposed method with the standard method to investigate differences in efficiency, measured by number of slides read, and accuracy, measured by probability of correct classification. Modelling varying sensitivity lowers the lower cut-off more significantly than the upper cut-off, correctly classifying regions as moderate rather than lower, thus receiving life-saving treatment. The classification method goes directly to classification on the basis of positive pools, avoiding having to know sensitivity to estimate prevalence. For model parameter values describing worm and egg distributions among children, the pooled method with 25 slides achieves an expected 89.9% probability of correct classification, whereas the standard method with 50 slides achieves 88.7%. Among children, it is more efficient and more accurate to use the pooled method for classification of S. mansoni prevalence than the current standard method. © 2012 Blackwell Publishing Ltd.
[Systematic review of the validity of urine cultures collected by sterile perineal bags].
Ochoa Sangrador, C; Pascual Terrazas, A
2016-02-01
The perineal adhesive bag is the most used method in our country for urine culture collection in infants, despite having a high risk of contamination and false-positive results. We aim to quantify both types of risks through a systematic review. Search updated in May 2014 in PUBMED, SCOPUS (includes EMBASE), IBECS; CINAHL, LILACS AND CUIDEN, without language or time limits. Percentages of contaminated urines, false positives, sensitivity and specificity (with respect to catheterization or bladder puncture) were recorded. A total of 21 studies of medium quality (7,659 samples) were selected. The pooled percentage of contaminated urines was 46.6% (15 studies; 6856 samples; 95% confidence interval [95% CI]: 35.6 to 57.8%; I(2): 97.3%). The pooled percentage of false positives was 61.1% (12 studies; 575 samples; 95% CI: 37.9 to 82.2%; I(2): 96.2%). Sensitivity (88%; 95% CI: 81-93%; I(2): 55.2%), and specificity (82%; 95% CI: 75-89%; I(2): 41.3%) were estimated in five studies, but without including contaminated urines. The perineal adhesive bag is not a valid enough method for urine culture collection, because almost half are contaminated and, if they are positive, two out of three are false. Although these estimates are imprecise, because of their great heterogeneity, they should be considered when choosing the method of urine collection. The estimates of sensitivity and specificity are not applicable because they do not take into account the risk of contamination. Copyright © 2015 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.
Wang, Zixing; Wang, Yuyan; Sui, Xin; Zhang, Wei; Shi, Ruihong; Zhang, Yingqiang; Dang, Yonghong; Qiao, Zhen; Zhang, Biao; Song, Wei; Jiang, Jingmei
2015-07-01
Widely used (18)F 2'-deoxy-2'-fluoro-d-glucose (FDG) positron emission tomography (PET) can be problematic with false positives in cancer imaging. This study aims to investigate the diagnostic accuracy of a candidate PET tracer, (18)F 2',3'-dideoxy-3'-fluoro-2-thiothymidine (FLT), in diagnosing pulmonary lesions compared with FDG. After comprehensive search and study selection, a meta-analysis was performed on data from 548 patients pooled from 17 studies for evaluating FLT accuracy, in which data from 351 patients pooled from ten double-tracer studies was used for direct comparison with FDG. Weighted sensitivity and specificity were used as main indicators of test performance. Individual data was extracted and patient subgroup analyses were performed. Overall, direct comparisons showed lower sensitivity (0.80 vs. 0.89) yet higher specificity (0.82 vs. 0.66) for FLT compared with FDG (both p<0.01). Patient subgroup analysis showed FLT was less sensitive than FDG in detecting lung cancers staged as T1 or T2, and those ≤2.0 cm in diameter (0.81 vs. 0.93, and 0.53 vs. 0.78, respectively, both p<0.05), but was comparable for cancers staged as T3 or T4, and those >2.0 cm in diameter (0.95 vs. 1.00, 0.96 vs. 0.88, both p>0.05). For benignities, FLT performed better compared with FDG in ruling out inflammation-based lesions (0.57 vs. 0.32, p<0.05), and demonstrated greater specificity regardless of lesion sizes. Although FLT cannot replace FDG in detecting small and early lung cancers, it may help to prevent patients with larger or inflammatory lesions from cancer misdiagnosis or even over-treatment. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Xuan, Min; Zhou, Fengsheng; Ding, Yan; Zhu, Qiaoying; Dong, Ji; Zhou, Hao; Cheng, Jun; Jiang, Xiao; Wu, Pengxi
2018-04-01
To review the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) used to detect residual or recurrent liver tumors after radiofrequency ablation (RFA). This technique uses contrast-enhanced computer tomography or/and contrast-enhanced magnetic resonance imaging as the gold standard of investigation. MEDLINE, EMBASE, and COCHRANE were systematically searched for all potentially eligible studies comparing CEUS with the reference standard that follows RFA. Risk of bias and applicability concerns were addressed by adopting the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Pooled point estimates for sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratios (DOR) with 95% CI were computed before plotting the sROC (summary receiver operating characteristic) curve. Meta-regression and subgroup analysis were used to identify the source of the heterogeneity that was detected. Publication bias was evaluated using Deeks' funnel plot asymmetry test. Ten eligible studies on 1162 lesions that occurred between 2001 and 2016 were included in the final analysis. The quality of the included studies assessed by the QUADAS-2 tool was considered reasonable. The pooled sensitivity and specificity of CEUS in detecting residual or recurrent liver tumors had the following values: 0.90 (95% CI 0.85-0.94) and 1.00 (95% CI 0.99-1.00), respectively. Overall DOR was 420.10 (95% CI 142.30-1240.20). The sources of heterogeneity could not be precisely identified by meta-regression or subgroup analysis. No evidence of publication bias was found. This study confirmed that CEUS exhibits high sensitivity and specificity in assessing therapeutic responses to RFA for liver tumors.
2014-01-01
Background The Timed Up and Go test (TUG) is a commonly used screening tool to assist clinicians to identify patients at risk of falling. The purpose of this systematic review and meta-analysis is to determine the overall predictive value of the TUG in community-dwelling older adults. Methods A literature search was performed to identify all studies that validated the TUG test. The methodological quality of the selected studies was assessed using the QUADAS-2 tool, a validated tool for the quality assessment of diagnostic accuracy studies. A TUG score of ≥13.5 seconds was used to identify individuals at higher risk of falling. All included studies were combined using a bivariate random effects model to generate pooled estimates of sensitivity and specificity at ≥13.5 seconds. Heterogeneity was assessed using the variance of logit transformed sensitivity and specificity. Results Twenty-five studies were included in the systematic review and 10 studies were included in meta-analysis. The TUG test was found to be more useful at ruling in rather than ruling out falls in individuals classified as high risk (>13.5 sec), with a higher pooled specificity (0.74, 95% CI 0.52-0.88) than sensitivity (0.31, 95% CI 0.13-0.57). Logistic regression analysis indicated that the TUG score is not a significant predictor of falls (OR = 1.01, 95% CI 1.00-1.02, p = 0.05). Conclusion The Timed Up and Go test has limited ability to predict falls in community dwelling elderly and should not be used in isolation to identify individuals at high risk of falls in this setting. PMID:24484314
Zhang, Peige; Zhang, Li; Zheng, Shaoping; Yu, Cheng; Xie, Mingxing; Lv, Qing
2016-01-01
To evaluate the overall performance of acoustic radiation force impulse imaging (ARFI) in differentiating between benign and malignant lymph nodes (LNs) by conducting a meta-analysis. PubMed, Embase, Web of Science, the Cochrane Library and the China National Knowledge Infrastructure were comprehensively searched for potential studies through August 13th, 2016. Studies that investigated the diagnostic power of ARFI for the differential diagnosis of benign and malignant LNs by using virtual touch tissue quantification (VTQ) or virtual touch tissue imaging quantification (VTIQ) were collected. The included articles were published in English or Chinese. Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) was used to evaluate the methodological quality. The pooled sensitivity, specificity, and the area under the summary receiver operating characteristic (SROC) curve (AUC) were calculated by means of a bivariate mixed-effects regression model. Meta-regression analysis was performed to identify the potential sources of between study heterogeneity. Fagan plot analysis was used to explore the clinical utilities. Publication bias was assessed using Deek's funnel plot. Nine studies involving 1084 LNs from 929 patients were identified to analyze in the meta-analysis. The summary sensitivity and specificity of ARFI in detecting malignant LNs were 0.87 (95% confidence interval [CI], 0.83-0.91) and 0.88 (95% CI, 0.82-0.92), respectively. The AUC was 0.93 (95% CI, 0.90-0.95). The pooled DOR was 49.59 (95% CI, 26.11-94.15). Deek's funnel plot revealed no significant publication bias. ARFI is a promising tool for the differentiation of benign and malignant LNs with high sensitivity and specificity.
Yu, Cheng; Xie, Mingxing; Lv, Qing
2016-01-01
Objective To evaluate the overall performance of acoustic radiation force impulse imaging (ARFI) in differentiating between benign and malignant lymph nodes (LNs) by conducting a meta-analysis. Methods PubMed, Embase, Web of Science, the Cochrane Library and the China National Knowledge Infrastructure were comprehensively searched for potential studies through August 13th, 2016. Studies that investigated the diagnostic power of ARFI for the differential diagnosis of benign and malignant LNs by using virtual touch tissue quantification (VTQ) or virtual touch tissue imaging quantification (VTIQ) were collected. The included articles were published in English or Chinese. Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) was used to evaluate the methodological quality. The pooled sensitivity, specificity, and the area under the summary receiver operating characteristic (SROC) curve (AUC) were calculated by means of a bivariate mixed-effects regression model. Meta-regression analysis was performed to identify the potential sources of between study heterogeneity. Fagan plot analysis was used to explore the clinical utilities. Publication bias was assessed using Deek’s funnel plot. Results Nine studies involving 1084 LNs from 929 patients were identified to analyze in the meta-analysis. The summary sensitivity and specificity of ARFI in detecting malignant LNs were 0.87 (95% confidence interval [CI], 0.83–0.91) and 0.88 (95% CI, 0.82–0.92), respectively. The AUC was 0.93 (95% CI, 0.90–0.95). The pooled DOR was 49.59 (95% CI, 26.11–94.15). Deek’s funnel plot revealed no significant publication bias. Conclusion ARFI is a promising tool for the differentiation of benign and malignant LNs with high sensitivity and specificity. PMID:27855188
Li, Bo; Sun, Zhiqiang; Li, Xiaohan; Li, Xiaoxi; Wang, Han; Chen, Weijiao; Chen, Peng; Qiao, Mengran; Mao, Yuanli
2017-04-01
There have been many inconsistent reports about the performance of histidine-rich protein 2 (HRP2) and lactate dehydrogenase (LDH) antigens as rapid diagnostic tests (RDTs) for the diagnosis of past Plasmodium falciparum infections. This meta-analysis was performed to determine the performance of pfHRP2 versus pLDH antigen RDTs in the detection of P. falciparum . After a systematic review of related studies, Meta-DiSc 1.4 software was used to calculate the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR). Forest plots and summary receiver operating characteristic curve (SROC) analysis were used to summarize the overall test performance. Fourteen studies which met the inclusion criteria were included in the meta-analysis. The summary performances for pfHRP2- and pLDH-based tests in the diagnosis of P. falciparum infections were as follows: pooled sensitivity, 96.3% (95.8-96.7%) vs. 82.6% (81.7-83.5%); specificity, 86.1% (85.3-86.8%) vs. 95.9% (95.4-96.3%); diagnostic odds ratio (DOR), 243.31 (97.679-606.08) vs. 230.59 (114.98-462.42); and area under ROCs, 0.9822 versus 0.9849 (all p < 0.001). The two RDTs performed satisfactorily for the diagnosis of P. falciparum , but the pLDH tests had higher specificity, whereas the pfHRP2 tests had better sensitivity. The pfHRP2 tests had slightly greater accuracy compared to the pLDH tests. A combination of both antigens might be a more reliable approach for the diagnosis of malaria.
Wan, Bing; Wang, Siqi; Tu, Mengqi; Wu, Bo; Han, Ping; Xu, Haibo
2017-03-01
The purpose of this meta-analysis was to evaluate the diagnostic accuracy of perfusion magnetic resonance imaging (MRI) as a method for differentiating glioma recurrence from pseudoprogression. The PubMed, Embase, Cochrane Library, and Chinese Biomedical databases were searched comprehensively for relevant studies up to August 3, 2016 according to specific inclusion and exclusion criteria. The quality of the included studies was assessed according to the quality assessment of diagnostic accuracy studies (QUADAS-2). After performing heterogeneity and threshold effect tests, pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated. Publication bias was evaluated visually by a funnel plot and quantitatively using Deek funnel plot asymmetry test. The area under the summary receiver operating characteristic curve was calculated to demonstrate the diagnostic performance of perfusion MRI. Eleven studies covering 416 patients and 418 lesions were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 0.88 (95% confidence interval [CI] 0.84-0.92), 0.77 (95% CI 0.69-0.84), 3.93 (95% CI 2.83-5.46), 0.16 (95% CI 0.11-0.22), and 27.17 (95% CI 14.96-49.35), respectively. The area under the summary receiver operating characteristic curve was 0.8899. There was no notable publication bias. Sensitivity analysis showed that the meta-analysis results were stable and credible. While perfusion MRI is not the ideal diagnostic method for differentiating glioma recurrence from pseudoprogression, it could improve diagnostic accuracy. Therefore, further research on combining perfusion MRI with other imaging modalities is warranted.
Diagnostic accuracy of the 14C-urea breath test in Helicobacter pylori infections: a meta-analysis.
Zhou, Qiaohui; Li, Ling; Ai, Yaowei; Pan, Zhihong; Guo, Mingwen; Han, Jingbo
2017-01-01
To summarize and appraise the available literature regarding the use of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspepsia and to calculate pooled diagnostic accuracy measures. We systematically searched the PubMed, EMBASE, Cochrane Library, Chinese Journals Full-text (CNKI) and CBMDisc databases to identify published data regarding the sensitivity, specificity, and other measures of diagnostic accuracy of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspeptic symptoms. Risk of bias was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies)-2 tool. Statistical analyses were performed using Meta-Disc 1.4 software and STATA. Eighteen studies met the inclusion criteria. Pooled results indicated that the 14 C-urea breath test showed a diagnostic sensitivity of 0.96 (95% CI 0.95 to 0.96) and specificity of 0.93 (95% CI 0.91 to 0.94). The positive like ratio (PLR) was 12.27 (95% CI 8.17 to 18.44), the negative like ratio (NLR) was 0.05 (95% CI 0.04 to 0.07), and the area under the curve was 0.985. The DOR was 294.95 (95% CI 178.37 to 487.70). The 14 C-urea breath test showed sufficient sensitivity and specificity for diagnosing Helicobacter pylori infection, but unexplained heterogeneity after meta-regression and several subgroup analyses remained. The UBT has high accuracy for diagnosing H. pylori infections in adult patients with dyspepsia. However, the reliability of these diagnostic meta-analytic estimates is limited by significant heterogeneity due to unknown factors.
Deng, Han; Qi, Xingshun; Zhang, Tiansong; Qi, Xiaolong; Yoshida, Eric M; Guo, Xiaozhong
2018-01-01
The meta-analysis aimed to summarize the technical success rate of supersonic shear imaging (SSI) and to evaluate the diagnostic performance of liver and spleen stiffness measurement (LSM and SSM) with SSI for the detection of liver fibrosis, portal hypertension, and gastroesophageal varices in liver diseases. PubMed, EMBASE, and Cochrane Library databases were searched. Technical success rate of SSI was pooled. Area under curve (AUC), sensitivity, and specificity with corresponding 95% confidence interval (CI) were calculated. Included studies regarding the diagnostic performance of SSI for liver fibrosis, portal hypertension, and esophageal varices numbered 28, 4, and 4 respectively. The pooled technical success rates of LSM and SSM were 95.3% and 75.5%, respectively. The AUC, sensitivity, and specificity of LSM/SSM for different stages of liver fibrosis were 0.85-0.94, 0.7-0.89, and 0.82-0.92, respectively. The AUC, sensitivity, and specificity of LSM were 0.84 (95%CI = 0.8-0.86), 0.79 (95%CI = 0.7-0.85), and 0.82 (95%CI = 0.72-0.88) for clinically significant portal hypertension, 0.85 (95%CI = 0.82-0.88), 0.8 (95%CI = 0.68-0.88), and 0.8 (95%CI = 0.6-0.92) for any varices, and 0.86 (95%CI = 0.83-0.89), 0.86 (95%CI = 0.76-0.92), and 0.61 (95%CI = 0.35-0.83) for high-risk varices, respectively. LSM with SSI had a high diagnostic accuracy for liver fibrosis, but a moderate diagnostic accuracy for portal hypertension and esophageal varices.
Microcolony culture techniques for tuberculosis diagnosis: a systematic review.
Leung, E; Minion, J; Benedetti, A; Pai, M; Menzies, D
2012-01-01
There is considerable demand for quicker and more affordable yet accurate diagnostic tools for tuberculosis (TB). The microscopic observation drug susceptibility (MODS) assay and the thin-layer agar (TLA) assay are inexpensive, rapid microcolony-based culture methods. A systematic review and meta-analysis was performed to assess the accuracy and other test characteristics of MODS and TLA compared to a reference standard of traditional solid or liquid culture. Pooled estimates of sensitivity and specificity and their 95% confidence intervals were estimated with an exact binomial likelihood random effects meta-analysis. A total of 21 eligible studies were identified, 12 that evaluated MODS, seven that evaluated TLA and two that evaluated both. The overall pooled sensitivity and specificity of MODS were respectively 92% (95%CI 87-97) and 96% (90-100), and for TLA they were respectively 87% (95%CI 79-94) and 98% (95%CI 94-100), although there was considerable heterogeneity of results. When the studies were restricted to those assessing accuracy of MODS in sputum samples only, the sensitivity was 96% (95%CI 94-98) and the specificity 96% (95%CI 89-100). The mean intervals from reception of specimens to results were 9.2 days with MODS and 11.5 days with TLA; contamination rates averaged 6.6% with MODS and 12.3% with TLA; materials and supplies costs averaged US$1.48 for MODS and US$2.42 for TLA. MODS and TLA appear to be accurate and rapid yet inexpensive diagnostic tools for active TB. However, this review did not find sufficient evidence on the feasibility and costs of implementation of these tests, nor on the impact of these tests on patient outcomes.
Ingenhoff, L; Hall, E; House, J K
2016-12-01
The three objectives of this study were to determine the positive predictive value (PPV) of oestrus diagnosis (heat detection accuracy) by dairy farmers, calculate the diagnostic sensitivity and specificity of the P4 Rapid milk progesterone assay for detecting a corpus luteum and evaluate the economics of using a cow-side milk progesterone assay designed to aid oestrus diagnosis. Milk samples were collected from 752 cows diagnosed in oestrus by farm personnel on 14 dairy farms. Samples were tested using the P4 Rapid milk progesterone assay to estimate the PPV of oestrus diagnosis at each farm and a crude pooled mean of PPV of oestrus diagnosis across all farms. A further 156 milk samples were collected from cows with luteal tissue status determined by transrectal ultrasound and tested by the P4 Rapid assay to enable calculation of the sensitivity and specificity of the P4 Rapid assay. For pooled farm samples, the PPV was 97.0%, with a range between farms of 88.9-100%. Sensitivity of the P4 Rapid milk progesterone assay for detecting a corpus luteum was 90.1% and specificity was 98.7%. Misclassification of oestrus in cows previously identified as pregnant was the most common cause of false-positive oestrus diagnoses by farm personnel. Routine testing of milk progesterone in all cows diagnosed in oestrus is not economically justified and may even slightly reduce submission rates; conversely, strategic use of cow-side milk progesterone assays can improve herd reproductive performance by facilitating decisions on whether to rebreed cows previously diagnosed as pregnant. © 2016 Australian Veterinary Association.
Li, Huimin; Yao, Liang; Jin, Penghui; Hu, Lidong; Li, Xiaofei; Guo, Tiankang; Yang, Kehu
2018-05-11
Neoadjuvant chemotherapy (NAC) has become an essential treatment for breast cancer. However, there is still no consensus on the best tool to evaluate pathological response to NAC. Two reviewers systematically searched Cochrane, PubMed, EMBASE, Web of Science, and CBM (last updated in February 2017) for eligible articles. We independently screened and selected studies that conformed to the inclusion criteria and extracted the requisite data. Pooled sensitivity, specificity, and the area under the SROC curve were calculated to estimate the diagnostic accuracy of magnetic resonance imaging (MRI) and positron emission computed tomography (PET/CT). And the relative DOR (RDOR) was used to compare accuracy for levels of the covariable. Thirteen studies involving 575 patients who underwent MRI and 618 who underwent PET/CT were included in our analysis. The pooled sensitivity and specificity of MRI were 0.88 (95% CI: 0.78-0.94) and 0.69 (95% CI: 0.51-0.83), respectively. The corresponding values for PET/CT were 0.77 (95% CI: 0.58-0.90) and 0.78 (95% CI: 0.63-0.88), respectively. The area under the SROC curve for MRI and PET/CT were 0.88 and 0.84, respectively. And the RDOR = 1.44 (95% CI, 0.46-4.47 P = 0.83). MRI had a higher sensitivity and PET/CT had a higher specificity in predicting the pathologic response after NAC in patients with breast cancer. According to the area under the SROC curve and anatomic discriminative resolution, MRI is the more suitable recommendation for predicting the pathologic response after NAC. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ma, Chunming; Liu, Yue; Lu, Qiang; Lu, Na; Liu, Xiaoli; Tian, Yiming; Wang, Rui; Yin, Fuzai
2016-02-01
The blood pressure-to-height ratio (BPHR) has been shown to be an accurate index for screening hypertension in children and adolescents. The aim of the present study was to perform a meta-analysis to assess the performance of BPHR for the assessment of hypertension. Electronic and manual searches were performed to identify studies of the BPHR. After methodological quality assessment and data extraction, pooled estimates of the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, area under the receiver operating characteristic curve and summary receiver operating characteristics were assessed systematically. The extent of heterogeneity for it was assessed. Six studies were identified for analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio values of BPHR, for assessment of hypertension, were 96% [95% confidence interval (CI)=0.95-0.97], 90% (95% CI=0.90-0.91), 10.68 (95% CI=8.03-14.21), 0.04 (95% CI=0.03-0.07) and 247.82 (95% CI=114.50-536.34), respectively. The area under the receiver operating characteristic curve was 0.9472. The BPHR had higher diagnostic accuracies for identifying hypertension in children and adolescents.
Ruilong, Zong; Daohai, Xie; Li, Geng; Xiaohong, Wang; Chunjie, Wang; Lei, Tian
2017-01-01
To carry out a meta-analysis on the performance of fluorine-18-fluorodeoxyglucose (F-FDG) PET/computed tomography (PET/CT) for the evaluation of solitary pulmonary nodules. In the meta-analysis, we performed searches of several electronic databases for relevant studies, including Google Scholar, PubMed, Cochrane Library, and several Chinese databases. The quality of all included studies was assessed by Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2). Two observers independently extracted data of eligible articles. For the meta-analysis, the total sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratios were pooled. A summary receiver operating characteristic curve was constructed. The I-test was performed to assess the impact of study heterogeneity on the results of the meta-analysis. Meta-regression and subgroup analysis were carried out to investigate the potential covariates that might have considerable impacts on heterogeneity. Overall, 12 studies were included in this meta-analysis, including a total of 1297 patients and 1301 pulmonary nodules. The pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio with corresponding 95% confidence intervals (CIs) were 0.82 (95% CI, 0.76-0.87), 0.81 (95% CI, 0.66-0.90), 4.3 (95% CI, 2.3-7.9), and 0.22 (95% CI, 0.16-0.30), respectively. Significant heterogeneity was observed in sensitivity (I=81.1%) and specificity (I=89.6%). Subgroup analysis showed that the best results for sensitivity (0.90; 95% CI, 0.68-0.86) and accuracy (0.93; 95% CI, 0.90-0.95) were present in a prospective study. The results of our analysis suggest that PET/CT is a useful tool for detecting malignant pulmonary nodules qualitatively. Although current evidence showed moderate accuracy for PET/CT in differentiating malignant from benign solitary pulmonary nodules, further work needs to be carried out to improve its reliability.
Yousefifard, Mahmoud; Baikpour, Masoud; Ghelichkhani, Parisa; Asady, Hadi; Shahsavari Nia, Kavous; Moghadas Jafari, Ali; Hosseini, Mostafa; Safari, Saeed
2016-01-01
The role of ultrasonography in detection of pleural effusion has long been a subject of interest but controversial results have been reported. Accordingly, this study aims to conduct a systematic review of the available literature on diagnostic value of ultrasonography and radiography in detection of pleural effusion through a meta-analytic approach. An extended search was done in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Two reviewers independently extracted the data and assessed the quality of the articles. Meta-analysis was performed using a mixed-effects binary regression model. Finally, subgroup analysis was carried out in order to find the sources of heterogeneity between the included studies. 12 studies were included in this meta-analysis (1554 subjects, 58.6% male). Pooled sensitivity of ultrasonography in detection of pleural effusion was 0.94 (95% CI: 0.88-0.97; I2= 84.23, p<0.001) and its pooled specificity was calculated to be 0.98 (95% CI: 0.92-1.0; I2= 88.65, p<0.001), while sensitivity and specificity of chest radiography were 0.51 (95% CI: 0.33-0.68; I2= 91.76, p<0.001) and 0.91 (95% CI: 0.68-0.98; I2= 92.86, p<0.001), respectively. Sensitivity of ultrasonography was found to be higher when the procedure was carried out by an intensivist or a radiologist using 5-10 MHz transducers. Chest ultrasonography, as a screening tool, has a higher diagnostic accuracy in identification of plural effusion compared to radiography. The sensitivity of this imaging modality was found to be higher when performed by a radiologist or an intensivist and using 5-10MHz probes.
Altez-Fernandez, Carlos; Ortiz, Victor; Mirzazadeh, Majid; Zegarra, Luis; Seas, Carlos; Ugarte-Gil, Cesar
2017-06-05
Genitourinary tuberculosis is the third most common form of extrapulmonary tuberculosis. Diagnosis is difficult because of unspecific clinical manifestations and low accuracy of conventional tests. Unfortunately, the delayed diagnosis impacts the urinary tract severely. Nucleic acid amplification tests yield fast results, and among these, new technologies can also detect drug resistance. There is lack of consensus regarding the use of these tests in genitourinary tuberculosis; we therefore aimed to assess the accuracy of nucleic acid amplification tests in the diagnosis of genitourinary tuberculosis and to evaluate the heterogeneity between studies. We did a systematic review and meta-analysis of research articles comparing the accuracy of a reference standard and a nucleic acid amplification test for diagnosis of urinary tract tuberculosis. We searched Medline, EMBASE, Web of Science, LILACS, Cochrane Library, and Scopus for articles published between Jan 1, 1990, and Apr 14, 2016. Two investigators identified eligible articles and extracted data for individual study sites. We analyzed data in groups with the same index test. Then, we generated pooled summary estimates (95% CIs) for sensitivity and specificity by use of random-effects meta-analysis when studies were not heterogeneous. We identified eleven relevant studies from ten articles, giving information on PCR, LCR and Xpert MTB/RIF tests. All PCR studies were "in-house" tests, with different gene targets and had several quality concerns therefore we did not proceed with a pooled analysis. Only one study used LCR. Xpert studies were of good quality and not heterogeneous, pooled sensitivity was 0·87 (0·66-0·96) and specificity was 0·91 (0·84-0·95). PCR studies were highly heterogeneous. Among Xpert MTB/RIF studies, specificity was favorable with an acceptable confidence interval, however new studies can update meta-analysis and get more precise estimates. Further high-quality studies are urgently needed to improve diagnosis of genitourinary tuberculosis. PROSPERO CRD42016039020.
Wang, Xin; Wang, Xiang Jiang; Song, Hui Sheng; Chen, Long Hua
2015-05-01
The aim of this study was to evaluate the diagnostic performance of the use of total choline signal-to-noise ratio (tCho SNR) criteria in MRS studies for benign/malignant discrimination of focal breast lesions. We conducted (1) a meta-analysis based on 10 studies including 480 malignant breast lesions and 312 benign breast lesions and (2) a subgroup meta-analysis of tCho SNR ≥ 2 as cutoff for malignancy based on 7 studies including 371 malignant breast lesions and 239 benign breast lesions. (1) The pooled sensitivity and specificity of proton MRS with tCho SNR were 0.74 (95 % CI 0.69-0.77) and 0.76 (95 % CI 0.71-0.81), respectively. The PLR and NLR were 3.67 (95 % CI 2.30-5.83) and 0.25 (95 % CI 0.14-0.42), respectively. From the fitted SROC, the AUC and Q* index were 0.89 and 0.82. Publication bias was present (t = 2.46, P = 0.039). (2) Meta-regression analysis suggested that neither threshold effect nor evaluated covariates including strength of field, pulse sequence, TR and TE were sources of heterogeneity (all P value >0.05). (3) Subgroup meta-analysis: The pooled sensitivity and specificity were 0.79 and 0.72, respectively. The PLR and NLR were 3.49 and 0.20, respectively. The AUC and Q* index were 0.92 and 0.85. The use of tCho SNR criteria in MRS studies was helpful for differentiation between malignant and benign breast lesions. However, pooled diagnostic measures might be overestimated due to publication bias. A tCho SNR ≥ 2 as cutoff for malignancy resulted in higher diagnostic accuracy.
Diaphragm and Lung Ultrasound to Predict Weaning Outcome: Systematic Review and Meta-Analysis.
Llamas-Álvarez, Ana M; Tenza-Lozano, Eva M; Latour-Pérez, Jaime
2017-12-01
Deciding the optimal timing for extubation in patients who are mechanically ventilated can be challenging, and traditional weaning predictor tools are not very accurate. The aim of this systematic review and meta-analysis was to assess the accuracy of lung and diaphragm ultrasound for predicting weaning outcomes in critically ill adults. MEDLINE, the Cochrane Library, Web of Science, Scopus, LILACS, Teseo, Tesis Doctorales en Red, and OpenGrey were searched, and the bibliographies of relevant studies were reviewed. Two researchers independently selected studies that met the inclusion criteria and assessed study quality in accordance with the Quality Assessment of Diagnostic Accuracy Studies-2 tool. The summary receiver-operating characteristic curve and pooled diagnostic OR (DOR) were estimated by using a bivariate random effects analysis. Sources of heterogeneity were explored by using predefined subgroup analyses and bivariate meta-regression. Nineteen studies involving 1,071 people were included in the study. For diaphragm thickening fraction, the area under the summary receiver-operating characteristic curve was 0.87, and DOR was 21 (95% CI, 11-40). Regarding diaphragmatic excursion, pooled sensitivity was 75% (95% CI, 65-85); pooled specificity, 75% (95% CI, 60-85); and DOR, 10 (95% CI, 4-24). For lung ultrasound, the area under the summary receiver-operating characteristic curve was 0.77, and DOR was 38 (95% CI, 7-198). Based on bivariate meta-regression analysis, a significantly higher specificity for diaphragm thickening fraction and higher sensitivity for diaphragmatic excursion was detected in studies with applicability concerns. Lung and diaphragm ultrasound can help predict weaning outcome, but its accuracy may vary depending on the patient subpopulation. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Mu, Xuetao; Wang, Hong; Ma, Qiaozhi; Wu, Chunnan; Ma, Lin
2014-06-01
The objective of this study was to determine the diagnostic accuracy of contrast-enhanced magnetic resonance angiography (MRA) when used in the preoperative evaluation of hepatic vascular anatomy in living liver donors. A computer-assisted literature searching of EMBASE, PubMed (MEDLINE), and the Cochrane library databases was conducted to identify potentially relevant articles which primarily examined the utility of contrast-enhanced MRA in the preoperative evaluation of hepatic vascular anatomy in living liver donors. We used the Q statistic of chi-squared value test and inconsistency index (I-squared, I(2)) to estimate the heterogeneity of the data extracted from all selected studies. Meta-Disc software (version 1.4) (ftp://ftp.hrc.es/pub/programas/metadisc/Metadisc_update.htm) was used to perform our analysis. Eight studies were included in the present meta-analysis. A total of 289 living liver donor candidates and 198 patients who underwent liver harvesting were included in the present study. The pooled sensitivities of hepatic artery (HA), portal vein (PV), and hepatic vein (HV) in this meta-analysis were 0.84, 0.97, and 0.94, respectively. The pooled specificities of HA, PV, and HV were 1.00, 1.00, and 1.00, respectively. The pooled diagnostic odds ratios of HA, PV, and HV were 127.28, 302.80, and 256.59, respectively. The area under the summary receiver-operating characteristic curves of HA, PV, and HV were 0.9917, 0.9960, and 0.9813, respectively. The high sensitivity and specificity demonstrated in this meta-analysis suggest that contrast-enhanced MRA was a promising test for the preoperative evaluation of hepatic vascular anatomy in living liver donors. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
Luo, Mingxu; Song, Hongmei; Liu, Gang; Lin, Yikai; Luo, Lintao; Zhou, Xin; Chen, Bo
2017-10-13
The diagnostic values of diffusion weighted imaging (DWI) and 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) for N-staging of gastric cancer (GC) were identified and compared. After a systematic search to identify relevant articles, meta-analysis was used to summarize the sensitivities, specificities, and areas under curves (AUCs) for DWI and PET/CT. To better understand the diagnostic utility of DWI and PET/CT for N-staging, the performance of multi-detector computed tomography (MDCT) was used as a reference. Fifteen studies were analyzed. The pooled sensitivity, specificity, and AUC with 95% confidence intervals of DWI were 0.79 (0.73-0.85), 0.69 (0.61-0.77), and 0.81 (0.77-0.84), respectively. For PET/CT, the corresponding values were 0.52 (0.39-0.64), 0.88 (0.61-0.97), and 0.66 (0.62-0.70), respectively. Comparison of the two techniques revealed DWI had higher sensitivity and AUC, but no difference in specificity. DWI exhibited higher sensitivity but lower specificity than MDCT, and 18 F-FDG PET/CT had lower sensitivity and equivalent specificity. Overall, DWI performed better than 18 F-FDG PET/CT for preoperative N-staging in GC. When the efficacy of MDCT was taken as a reference, DWI represented a complementary imaging technique, while 18 F-FDG PET/CT had limited utility for preoperative N-staging.
Lindan, Christina; Mathur, Meenakshi; Kumta, Sameer; Jerajani, Hermangi; Gogate, Alka; Schachter, Julius; Moncada, Jeanne
2005-04-01
Pooling urogenital specimens for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae by nucleic acid amplification tests is an attractive alternative to individual testing. As pooling can reduce the costs of testing as well as labor, it has been advocated for use in resource-poor settings. However, it has neither been widely adopted nor evaluated for use in developing countries. We evaluated the practical use of pooling first-catch urine (FCU) specimens for the detection of C. trachomatis and N. gonorrhoeae from 690 men in Mumbai, India, by PCR. FCU, urethral smears, and swabs were collected from men seen at two sexually transmitted infection (STI) clinics. All laboratory testing was done at the Lokmanya Tilak General Hospital. Gram stain smears and culture isolation for N. gonorrhoeae were performed. Each FCU was tested individually and in pools using the Roche Amplicor PCR for C. trachomatis and N. gonorrhoeae with an internal control for inhibition. Specimen pools consisted of aliquots from five consecutively processed FCUs combined into an amplification tube. An optical density reading of > or =0.20 indicated a pool for which subsequent testing of individual samples was required. Prevalence by PCR on single specimens was 2.2% (15/690) for C. trachomatis and 5.4% (37/690) for N. gonorrhoeae. Compared to individual FCU results, pooling for C. trachomatis and N. gonorrhoeae had an overall sensitivity of 96.1% (50/52). Specificity was 96.5% (83/86) in that three pools required single testing that failed to identify a positive specimen. Pooling missed two positive specimens, decreased the inhibition rate, and saved 50.3% of reagent costs. In this resource-limited setting, the use of pooling to detect C. trachomatis and N. gonorrhoeae by PCR proved to be a simple, accurate, and cost-effective procedure compared to individual testing.
ELISA versus PCR for diagnosis of chronic Chagas disease: systematic review and meta-analysis
2010-01-01
Background Most current guidelines recommend two serological tests to diagnose chronic Chagas disease. When serological tests are persistently inconclusive, some guidelines recommend molecular tests. The aim of this investigation was to review chronic Chagas disease diagnosis literature and to summarize results of ELISA and PCR performance. Methods A systematic review was conducted searching remote databases (MEDLINE, LILACS, EMBASE, SCOPUS and ISIWeb) and full texts bibliography for relevant abstracts. In addition, manufacturers of commercial tests were contacted. Original investigations were eligible if they estimated sensitivity and specificity, or reliability -or if their calculation was possible - of ELISA or PCR tests, for chronic Chagas disease. Results Heterogeneity was high within each test (ELISA and PCR) and threshold effect was detected only in a particular subgroup. Reference standard blinding partially explained heterogeneity in ELISA studies, and pooled sensitivity and specificity were 97.7% [96.7%-98.5%] and 96.3% [94.6%-97.6%] respectively. Commercial ELISA with recombinant antigens studied in phase three investigations partially explained heterogeneity, and pooled sensitivity and specificity were 99.3% [97.9%-99.9%] and 97.5% [88.5%-99.5%] respectively. ELISA's reliability was seldom studied but was considered acceptable. PCR heterogeneity was not explained, but a threshold effect was detected in three groups created by using guanidine and boiling the sample before DNA extraction. PCR sensitivity is likely to be between 50% and 90%, while its specificity is close to 100%. PCR reliability was never studied. Conclusions Both conventional and recombinant based ELISA give useful information, however there are commercial tests without technical reports and therefore were not included in this review. Physicians need to have access to technical reports to understand if these serological tests are similar to those included in this review and therefore correctly order and interpret test results. Currently, PCR should not be used in clinical practice for chronic Chagas disease diagnosis and there is no PCR test commercially available for this purpose. Tests limitations and directions for future research are discussed. PMID:21108793
Accurate clinical detection of exon copy number variants in a targeted NGS panel using DECoN.
Fowler, Anna; Mahamdallie, Shazia; Ruark, Elise; Seal, Sheila; Ramsay, Emma; Clarke, Matthew; Uddin, Imran; Wylie, Harriet; Strydom, Ann; Lunter, Gerton; Rahman, Nazneen
2016-11-25
Background: Targeted next generation sequencing (NGS) panels are increasingly being used in clinical genomics to increase capacity, throughput and affordability of gene testing. Identifying whole exon deletions or duplications (termed exon copy number variants, 'exon CNVs') in exon-targeted NGS panels has proved challenging, particularly for single exon CNVs. Methods: We developed a tool for the Detection of Exon Copy Number variants (DECoN), which is optimised for analysis of exon-targeted NGS panels in the clinical setting. We evaluated DECoN performance using 96 samples with independently validated exon CNV data. We performed simulations to evaluate DECoN detection performance of single exon CNVs and to evaluate performance using different coverage levels and sample numbers. Finally, we implemented DECoN in a clinical laboratory that tests BRCA1 and BRCA2 with the TruSight Cancer Panel (TSCP). We used DECoN to analyse 1,919 samples, validating exon CNV detections by multiplex ligation-dependent probe amplification (MLPA). Results: In the evaluation set, DECoN achieved 100% sensitivity and 99% specificity for BRCA exon CNVs, including identification of 8 single exon CNVs. DECoN also identified 14/15 exon CNVs in 8 other genes. Simulations of all possible BRCA single exon CNVs gave a mean sensitivity of 98% for deletions and 95% for duplications. DECoN performance remained excellent with different levels of coverage and sample numbers; sensitivity and specificity was >98% with the typical NGS run parameters. In the clinical pipeline, DECoN automatically analyses pools of 48 samples at a time, taking 24 minutes per pool, on average. DECoN detected 24 BRCA exon CNVs, of which 23 were confirmed by MLPA, giving a false discovery rate of 4%. Specificity was 99.7%. Conclusions: DECoN is a fast, accurate, exon CNV detection tool readily implementable in research and clinical NGS pipelines. It has high sensitivity and specificity and acceptable false discovery rate. DECoN is freely available at www.icr.ac.uk/decon.
Tsai, Alexander C.; Scott, Jennifer A.; Hung, Kristin J.; Zhu, Jennifer Q.; Matthews, Lynn T.; Psaros, Christina; Tomlinson, Mark
2013-01-01
Background A major barrier to improving perinatal mental health in Africa is the lack of locally validated tools for identifying probable cases of perinatal depression or for measuring changes in depression symptom severity. We systematically reviewed the evidence on the reliability and validity of instruments to assess perinatal depression in African settings. Methods and Findings Of 1,027 records identified through searching 7 electronic databases, we reviewed 126 full-text reports. We included 25 unique studies, which were disseminated in 26 journal articles and 1 doctoral dissertation. These enrolled 12,544 women living in nine different North and sub-Saharan African countries. Only three studies (12%) used instruments developed specifically for use in a given cultural setting. Most studies provided evidence of criterion-related validity (20 [80%]) or reliability (15 [60%]), while fewer studies provided evidence of construct validity, content validity, or internal structure. The Edinburgh postnatal depression scale (EPDS), assessed in 16 studies (64%), was the most frequently used instrument in our sample. Ten studies estimated the internal consistency of the EPDS (median estimated coefficient alpha, 0.84; interquartile range, 0.71-0.87). For the 14 studies that estimated sensitivity and specificity for the EPDS, we constructed 2 x 2 tables for each cut-off score. Using a bivariate random-effects model, we estimated a pooled sensitivity of 0.94 (95% confidence interval [CI], 0.68-0.99) and a pooled specificity of 0.77 (95% CI, 0.59-0.88) at a cut-off score of ≥9, with higher cut-off scores yielding greater specificity at the cost of lower sensitivity. Conclusions The EPDS can reliably and validly measure perinatal depression symptom severity or screen for probable postnatal depression in African countries, but more validation studies on other instruments are needed. In addition, more qualitative research is needed to adequately characterize local understandings of perinatal depression-like syndromes in different African contexts. PMID:24340036
Lv, S; Zhao, J; Zhang, J; Kwon, S; Han, M; Bian, R; Fu, H; Zhang, Y; Pan, H
2014-08-01
In our previous study, tumor necrosis factor α (TNF-α) was identified as an effective target for sepsis patients (Int J Clin Pract, 68, 2014, 520). TNF-α in cerebrospinal fluid (CSF) was also investigated for its utility in the differential diagnosis of bacterial and aseptic meningitis. However, there has been neither definite nor convincing evidence so far. Here the overall diagnostic accuracy of TNF-α in differentiation between bacterial and aseptic meningitis was evaluated through the meta-analysis of diagnostic tests. The sensitivity, specificity and other measures of accuracy were pooled using random effect models. Summary receiver operating characteristic curves were used to assess overall test performance. Publication bias was evaluated using funnel plots, and sensitivity analysis was also introduced. A total of 21 studies involving bacterial meningitis (678) and aseptic meningitis (694) involved a total of 1372 patients. The pooled sensitivity and specificity for the TNF-α test were 0.83 [95% confidence interval (CI) 0.80-0.86, I(2) = 65.1] and 0.92 (95% CI 0.89-0.94, I(2) = 61.8), respectively. The positive likelihood ratio was 12.05 (95% CI 7.41-19.60, I(2) = 36.5), the negative likelihood ratio was 0.17 (95% CI 0.13-0.24, I(2) = 59.4), and TNF-α was significantly associated with bacterial meningitis, with a diagnostic odds ratio of 49.84 (95% CI 28.53-87.06, I(2) = 47.9). The overall accuracy of the TNF-α test was very high with the area under the curve 0.9317. Publication bias was absent, and sensitivity analysis suggested that our results were highly stable. Our meta-analysis suggested that TNF-α could be recommended as a useful marker for diagnosis of bacterial meningitis and differential diagnosis between bacterial and aseptic meningitis with high sensitivity and specificity. Thus, hospitals should be encouraged to conduct TNF-α tests in CSF after lumbar puncture. © 2014 The Author(s) European Journal of Neurology © 2014 EAN.
miRNAs as biomarkers for diagnosis of heart failure: A systematic review and meta-analysis.
Yan, Hualin; Ma, Fan; Zhang, Yi; Wang, Chuan; Qiu, Dajian; Zhou, Kaiyu; Hua, Yimin; Li, Yifei
2017-06-01
With the rapid development of molecular biology, the kind of mircoRNA (miRNA) has been introduced into emerging role both in cardiac development and pathological procedure. Thus, we conduct this meta-analysis to find out the role of circulating miRNA as a biomarker in detecting heart failure. We searched PubMed, EMBASE, the Cochrane Central Register of Controlled Trials, and World Health Organization clinical trials registry center to identify relevant studies up to August 2016. We performed meta-analysis in a fixed/random-effect model using Meta-disc 1.4. We used STATA 14.0 to estimate the publication bias and meta-regression. Besides, we took use of SPSS 17.0 to evaluate variance between several groups. Information on true positive, false positive, false negative, and true negative, as well as the quality of research was extracted. We use results from 10 articles to analyze the pooled accuracy. The overall performance of total mixed miRNAs (TmiRs) detection was: pooled sensitivity, 0.74 (95% confidence interval [CI], 0.72 to 0.75); pooled specificity, 0.69 (95%CI, 0.67 to 0.71); and area under the summary receiver operating characteristic curves value (SROC), 0.7991. The miRNA-423-5p (miR-423-5p) detection was: pooled sensitivity, 0.81 (95%CI, 0.76 to 0.85); pooled specificity, 0.67 (95%CI, 0.61 to 0.73); and SROC, 0.8600. However, taken the same patients population, we extracted the data of BNP for detecting heart failure and performed meta-analysis with acceptable SROC as 0.9291. Among the variance analysis, the diagnostic performance of miR-423-5p claimed significant advantages of other pooled results. However, the combination of miRNAs and BNP could increase the accuracy of detecting of heart failure. Unfortunately, there was no dramatic advantage of miR-423-5p compared to BNP protocol. Despite interstudy variability, the performance test of miRNA for detecting heart failure revealed that miR-423-5p demonstrated the potential to be a biomarker. However, other miRNAs were not able to provide enough evidence on promising diagnostic value for heart failure based on the current data. Moreover, the combination of miRNAs and BNP could work as a better method to detection. Unfortunately, BNP was still the most convinced biomarker for such disease.
miRNAs as biomarkers for diagnosis of heart failure
Yan, Hualin; Ma, Fan; Zhang, Yi; Wang, Chuan; Qiu, Dajian; Zhou, Kaiyu; Hua, Yimin; Li, Yifei
2017-01-01
Abstract Background: With the rapid development of molecular biology, the kind of mircoRNA (miRNA) has been introduced into emerging role both in cardiac development and pathological procedure. Thus, we conduct this meta-analysis to find out the role of circulating miRNA as a biomarker in detecting heart failure. Methods: We searched PubMed, EMBASE, the Cochrane Central Register of Controlled Trials, and World Health Organization clinical trials registry center to identify relevant studies up to August 2016. We performed meta-analysis in a fixed/random-effect model using Meta-disc 1.4. We used STATA 14.0 to estimate the publication bias and meta-regression. Besides, we took use of SPSS 17.0 to evaluate variance between several groups. Information on true positive, false positive, false negative, and true negative, as well as the quality of research was extracted. Results: We use results from 10 articles to analyze the pooled accuracy. The overall performance of total mixed miRNAs (TmiRs) detection was: pooled sensitivity, 0.74 (95% confidence interval [CI], 0.72 to 0.75); pooled specificity, 0.69 (95%CI, 0.67 to 0.71); and area under the summary receiver operating characteristic curves value (SROC), 0.7991. The miRNA-423-5p (miR-423-5p) detection was: pooled sensitivity, 0.81 (95%CI, 0.76 to 0.85); pooled specificity, 0.67 (95%CI, 0.61 to 0.73); and SROC, 0.8600. However, taken the same patients population, we extracted the data of BNP for detecting heart failure and performed meta-analysis with acceptable SROC as 0.9291. Among the variance analysis, the diagnostic performance of miR-423-5p claimed significant advantages of other pooled results. However, the combination of miRNAs and BNP could increase the accuracy of detecting of heart failure. Unfortunately, there was no dramatic advantage of miR-423-5p compared to BNP protocol. Conclusion: Despite interstudy variability, the performance test of miRNA for detecting heart failure revealed that miR-423-5p demonstrated the potential to be a biomarker. However, other miRNAs were not able to provide enough evidence on promising diagnostic value for heart failure based on the current data. Moreover, the combination of miRNAs and BNP could work as a better method to detection. Unfortunately, BNP was still the most convinced biomarker for such disease. PMID:28562533
DNA capture elements for rapid detection and identification of biological agents
NASA Astrophysics Data System (ADS)
Kiel, Johnathan L.; Parker, Jill E.; Holwitt, Eric A.; Vivekananda, Jeeva
2004-08-01
DNA capture elements (DCEs; aptamers) are artificial DNA sequences, from a random pool of sequences, selected for their specific binding to potential biological warfare agents. These sequences were selected by an affinity method using filters to which the target agent was attached and the DNA isolated and amplified by polymerase chain reaction (PCR) in an iterative, increasingly stringent, process. Reporter molecules were attached to the finished sequences. To date, we have made DCEs to Bacillus anthracis spores, Shiga toxin, Venezuelan Equine Encephalitis (VEE) virus, and Francisella tularensis. These DCEs have demonstrated specificity and sensitivity equal to or better than antibody.
Zainathan, S C; Carson, J; Crane, M St J; Nowak, B F
2013-04-01
The use of swabs relative to organs as a sample collection method for the detection of Tasmanian salmon reovirus (TSRV) in farmed Tasmanian Atlantic salmon, Salmo salar L., was evaluated by RT-qPCR. Evaluation of individual and pooled sample collection (organs vs swabs) was carried out to determine the sensitivity of the collection methods and the effect of pooling of samples for the detection of TSRV. Detection of TSRV in individual samples was as sensitive when organs were sampled compared to swabs, and in pooled samples, organs demonstrated a sensitivity of one 10-fold dilution higher than sampling of pooled swabs. Storage of swabs at 4 °C for t = 24 h demonstrated results similar to those at t = 0. Advantages of using swabs as a preferred sample collection method for the detection of TSRV compared to organ samples are evident from these experimental trials. © 2012 Blackwell Publishing Ltd.
Modelling the sensitivity of life history traits to climate change in a temporary pool crustacean.
Pinceel, Tom; Vanschoenwinkel, Bram; Brendonck, Luc; Buschke, Falko
2016-07-11
Temporary pool inhabitants face altered inundation regimes under climate change. While their exposure to these changes has received considerable attention, few studies have investigated their sensitivity or adaptability. Here, we use zooplankton as a model to explore how decreasing hydroperiods affect extinction risks and assess whether changes in life history traits could promote persistence. For this, we construct a three-stage matrix population model parameterised with realistic life-history values for the fairy shrimp Branchipodopsis wolfi from pools with varying hydroperiods. Our results suggest that extinction risks increase drastically once the median hydroperiod drops below a critical threshold. Although changes in life-history parameters could potentially compensate for this risk, the relative importance of each trait for population growth depends on the median hydroperiod. For example, survival of dormant eggs seemed to be most important when hydroperiods were short while the survival of freshly laid eggs and adult individuals were more important in longer-lived pools. Overall, this study demonstrates that zooplankton species are sensitive to climate change and that the adaptive capacity of organisms from temporary pools with dissimilar hydrology hinges on selection of different life history traits.
Gebrekidan, Hagos; Gasser, Robin B; Stevenson, Mark A; McGrath, Sean; Jabbar, Abdul
2017-02-01
Oriental theileriosis caused by multiple genotypes of Theileria orientalis is an important tick-borne disease of bovines. Here, we assessed the performance of an established multiplexed tandem PCR (MT-PCR) for the diagnosis of the two recognized, pathogenic genotypes (chitose and ikeda) of T. orientalis in cattle using pooled blood samples. We used a total of 265 cattle blood samples, which were divided into two groups according to previous MT-PCR results for individual samples. Samples in group 1 (n = 155) were from a herd with a relatively high prevalence of T. orientalis infection; and those in group 2 (n = 110) were from four herds with a low prevalence. For group 1, 31 and 15 batches of five- and ten-pooled samples (selected at random), respectively, were formed. For group 2, 22 and 11 batches of five- and ten-pooled samples (selected at random), respectively, were formed. DNAs from individual pooled samples in each batch and group were then tested by MT-PCR. For group 1, the apparent prevalences estimated using the 31 batches of five-pooled samples (97%) and 15 batches of ten-pooled samples (100%) were significantly higher compared with individual samples (75%). For group 2, higher apparent prevalences (9% and 36%) were also recorded for the 22 and 11 batches of pooled samples, respectively, compared with individual samples (7%). Overall, the average infection intensity recorded for the genotypes of chitose and ikeda were considerably lower in pooled compared with individual samples. The diagnostic specificities of MT-PCR were estimated at 95% and 94%, respectively, when batches of five- and ten-pooled samples were tested, and 94% for individual samples. The diagnostic sensitivity of this assay was estimated at 98% same for all individual, five- and ten-pooled samples. This study shows that screening batches of five- and ten-pooled blood samples from cattle herds are similar to those obtained for individual samples, and, importantly, that the reduced cost for the testing of pooled samples represents a considerable saving to herd managers. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pham, Thomas A; Lee, Jacqueline I; Melcher, Marc L
2017-01-01
With organs in short supply, only a limited number of kidney transplants can be performed a year. Live donor donation accounts for 1/3rd of all kidney transplants performed in the United States. Unfortunately, not every donor recipient pair is feasible because of Human leukocyte antigen (HLA) sensitization and ABO incompatibility. To overcome these barriers to transplant, strategies such as kidney paired donation (KPD) and desensitization have been developed. KPD is the exchange of donors between at least two incompatible donor-recipient pairs such that they are now compatible. Desensitization is the removal of circulating donor specific antibodies to prevent graft rejection. Regardless of the treatment strategy, highly sensitized patients whose calculated panel reactive antibody (cPRA) is ≥95% remain difficult to transplant with match rates as low as 15% in KPD pools. Desensitization has proved to be difficult in those with high antibody titers. A novel approach is the combination of both KPD and desensitization to facilitate compatible and successful transplantation. A highly sensitized patient can be paired with a better immunological match in the KPD pool and subsequently desensitized to a lesser degree. This article reviews the current progress in KPD and desensitization and their use as a combined therapy. Copyright © 2017 Elsevier Inc. All rights reserved.
Conde-Agudelo, Agustin; Romero, Roberto
2015-12-01
To determine the accuracy of changes in transvaginal sonographic cervical length over time in predicting preterm birth in women with singleton and twin gestations. PubMed, Embase, Cinahl, Lilacs, and Medion (all from inception to June 30, 2015), bibliographies, Google scholar, and conference proceedings. Cohort or cross-sectional studies reporting on the predictive accuracy for preterm birth of changes in cervical length over time. Two reviewers independently selected studies, assessed the risk of bias, and extracted the data. Summary receiver-operating characteristic curves, pooled sensitivities and specificities, and summary likelihood ratios were generated. Fourteen studies met the inclusion criteria, of which 7 provided data on singleton gestations (3374 women) and 8 on twin gestations (1024 women). Among women with singleton gestations, the shortening of cervical length over time had a low predictive accuracy for preterm birth at <37 and <35 weeks of gestation with pooled sensitivities and specificities, and summary positive and negative likelihood ratios ranging from 49% to 74%, 44% to 85%, 1.3 to 4.1, and 0.3 to 0.7, respectively. In women with twin gestations, the shortening of cervical length over time had a low to moderate predictive accuracy for preterm birth at <34, <32, <30, and <28 weeks of gestation with pooled sensitivities and specificities, and summary positive and negative likelihood ratios ranging from 47% to 73%, 84% to 89%, 3.8 to 5.3, and 0.3 to 0.6, respectively. There were no statistically significant differences between the predictive accuracies for preterm birth of cervical length shortening over time and the single initial and/or final cervical length measurement in 8 of 11 studies that provided data for making these comparisons. In the largest and highest-quality study, a single measurement of cervical length obtained at 24 or 28 weeks of gestation was significantly more predictive of preterm birth than any decrease in cervical length between these gestational ages. Change in transvaginal sonographic cervical length over time is not a clinically useful test to predict preterm birth in women with singleton or twin gestations. A single cervical length measurement obtained between 18 and 24 weeks of gestation appears to be a better test to predict preterm birth than changes in cervical length over time. Published by Elsevier Inc.
Improvement of sampling plans for Salmonella detection in pooled table eggs by use of real-time PCR.
Pasquali, Frédérique; De Cesare, Alessandra; Valero, Antonio; Olsen, John Emerdhal; Manfreda, Gerardo
2014-08-01
Eggs and egg products have been described as the most critical food vehicles of salmonellosis. The prevalence and level of contamination of Salmonella on table eggs are low, which severely affects the sensitivity of sampling plans applied voluntarily in some European countries, where one to five pools of 10 eggs are tested by the culture based reference method ISO 6579:2004. In the current study we have compared the testing-sensitivity of the reference culture method ISO 6579:2004 and an alternative real-time PCR method on Salmonella contaminated egg-pool of different sizes (4-9 uninfected eggs mixed with one contaminated egg) and contamination levels (10°-10(1), 10(1)-10(2), 10(2)-10(3)CFU/eggshell). Two hundred and seventy samples corresponding to 15 replicates per pool size and inoculum level were tested. At the lowest contamination level real-time PCR detected Salmonella in 40% of contaminated pools vs 12% using ISO 6579. The results were used to estimate the lowest number of sample units needed to be tested in order to have a 95% certainty not falsely to accept a contaminated lot by Monte Carlo simulation. According to this simulation, at least 16 pools of 10 eggs each are needed to be tested by ISO 6579 in order to obtain this confidence level, while the minimum number of pools to be tested was reduced to 8 pools of 9 eggs each, when real-time PCR was applied as analytical method. This result underlines the importance of including analytical methods with higher sensitivity in order to improve the efficiency of sampling and reduce the number of samples to be tested. Copyright © 2013 Elsevier B.V. All rights reserved.
Morandi, Pierre-Alain; Schockmel, Gérard A.; Yerly, Sabine; Burgisser, Philippe; Erb, Peter; Matter, Lukas; Sitavanc, Radan; Perrin, Luc
1998-01-01
A total of 234 pools were prepared from 10,692 consecutive serum samples negative for antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 collected at five virological laboratories (average pool size, 45 serum samples). Pools were screened for the presence of HIV-1 RNA by a modified commercial assay (Amplicor HIV-1 Monitor test) which included an additional polyethylene glycol (PEG) precipitation step prior to purification of viral RNA (PEG Amplicor assay). The sensitivity of this assay for HIV-1 RNA detection in individual serum samples within pools matches that of standard commercial assays for individual serum samples, i.e., 500 HIV-1 RNA copies per ml. Five pools were identified as positive, and each one contained one antibody-negative, HIV-1 RNA-positive serum sample, corresponding to an average of 1 infected sample per 2,138 serum samples. Retrospective analysis revealed that the five HIV-1 RNA-positive specimens originated from individuals who had symptomatic primary HIV-1 infection at the time of sample collection and who were also positive for p24 antigenemia. We next assessed the possibility of performing the prepurification step by high-speed centrifugation (50,000 × g for 80 min) of 1.5-ml pools containing 25 μl of 60 individual serum samples, of which only 1 contained HIV-1 RNA (centrifugation Amplicor assay). The sensitivity of this assay also matches the sensitivities of standard commercial assays for HIV-1 RNA detection in individual serum samples. The results demonstrate that both assays with pooled sera can be applied to the screening of large numbers of serum samples in a time- and cost-efficient manner. PMID:9620372
Modelling the sensitivity of soil mercury storage to climate-induced changes in soil carbon pools
NASA Astrophysics Data System (ADS)
Hararuk, O.; Obrist, D.; Luo, Y.
2013-04-01
Substantial amounts of mercury (Hg) in the terrestrial environment reside in soils and are associated with soil organic carbon (C) pools, where they accumulated due to increased atmospheric deposition resulting from anthropogenic activities. The purpose of this study was to examine potential sensitivity of surface soil Hg pools to global change variables, particularly affected by predicted changes in soil C pools, in the contiguous US. To investigate, we included a soil Hg component in the Community Land Model based on empirical statistical relationships between soil Hg / C ratios and precipitation, latitude, and clay; and subsequently explored the sensitivity of soil C and soil Hg densities (i.e., areal-mass) to climate scenarios in which we altered annual precipitation, carbon dioxide (CO2) concentrations and temperature. Our model simulations showed that current sequestration of Hg in the contiguous US accounted for 15 230 metric tons of Hg in the top 0-40 cm of soils, or for over 300 000 metric tons when extrapolated globally. In the simulations, US soil Hg pools were most sensitive to changes in precipitation because of strong effects on soil C pools, plus a direct effect of precipitation on soil Hg / C ratios. Soil Hg pools were predicted to increase beyond present-day values following an increase in precipitation amounts and decrease following a reduction in precipitation. We found pronounced regional differences in sensitivity of soil Hg to precipitation, which were particularly high along high-precipitation areas along the West and East Coasts. Modelled increases in CO2 concentrations to 700 ppm stimulated soil C and Hg accrual, while increased air temperatures had small negative effects on soil C and Hg densities. The combined effects of increased CO2, increased temperature and increased or decreased precipitation were strongly governed by precipitation and CO2 showing pronounced regional patterns. Based on these results, we conclude that the combination of precipitation and CO2 should be emphasised when assessing how climate-induced changes in soil C may affect sequestration of Hg in soils.
A computational relationship between thalamic sensory neural responses and contrast perception.
Jiang, Yaoguang; Purushothaman, Gopathy; Casagrande, Vivien A
2015-01-01
Uncovering the relationship between sensory neural responses and perceptual decisions remains a fundamental problem in neuroscience. Decades of experimental and modeling work in the sensory cortex have demonstrated that a perceptual decision pool is usually composed of tens to hundreds of neurons, the responses of which are significantly correlated not only with each other, but also with the behavioral choices of an animal. Few studies, however, have measured neural activity in the sensory thalamus of awake, behaving animals. Therefore, it remains unclear how many thalamic neurons are recruited and how the information from these neurons is pooled at subsequent cortical stages to form a perceptual decision. In a previous study we measured neural activity in the macaque lateral geniculate nucleus (LGN) during a two alternative forced choice (2AFC) contrast detection task, and found that single LGN neurons were significantly correlated with the monkeys' behavioral choices, despite their relatively poor contrast sensitivity and a lack of overall interneuronal correlations. We have now computationally tested a number of specific hypotheses relating these measured LGN neural responses to the contrast detection behavior of the animals. We modeled the perceptual decisions with different numbers of neurons and using a variety of pooling/readout strategies, and found that the most successful model consisted of about 50-200 LGN neurons, with individual neurons weighted differentially according to their signal-to-noise ratios (quantified as d-primes). These results supported the hypothesis that in contrast detection the perceptual decision pool consists of multiple thalamic neurons, and that the response fluctuations in these neurons can influence contrast perception, with the more sensitive thalamic neurons likely to exert a greater influence.
Kulshrestha, Pankaj; McKinstry, Katherine C; Fernandez, Bernadette O; Feelisch, Martin; Mitch, William A
2010-05-01
Although N-nitrosodimethylamine (NDMA) has been the most prevalent N-nitrosamine detected in disinfected waters, it remains unclear whether NDMA is indeed the most significant N-nitrosamine or just one representative of a larger pool of N-nitrosamines. A widely used assay applied to quantify nitrite, S-nitrosothiols, and N-nitrosamines in biological samples involves their reduction to nitric oxide by acidic tri-iodide, followed by chemiluminescent detection of the evolved nitric oxide in the gas phase. We here describe an adaptation of this method for analyzing total N-nitrosamine (TONO) concentrations in disinfected pools. Optimal sensitivity for N-nitrosamines was obtained using a reduction solution containing 13.5 mL glacial acetic acid and 1 mL of an aqueous 540 g/L iodide and 114 g/L iodine solution held at 80 degrees C. The method detection limit for N-nitrosamines was 110 nM using 100 microL sample injections and NDMA as a standard. N-nitrosamines featuring a range of polarities were converted to nitric oxide with 75-103% efficiency compared to NDMA. Evaluation of potential interfering species indicated that only nitrite and S-nitrosothiols were a concern, but both interferences were effectively eliminated using group-specific sample pretreatments previously employed for biological samples. To evaluate the low TONO concentrations anticipated for pools, 1 L samples were extracted by continuous liquid-liquid extraction with ethyl acetate for 24 h, and concentrated to 1 mL. N-nitrosamine recovery during extraction ranged from 37-75%, and there was a potential for artifactual nitrosation of amines during solvent reflux in the presence of significant nitrite concentrations, but not at the low nitrite concentrations prevalent in most pools. Using the 1000-fold concentration factor and 56% average extraction efficiency, the method detection limit would be 62 pM (5 ng/L as NDMA). The TONO assay was applied to six pools and their common tap water source in conjunction with analysis for specific nitrosamines. Even accounting for the range of N-nitrosamine extraction recoveries, NDMA accounted for an average of only 13% (range 3-46%) of the total nitrosamine pool.
The influence of weather on migraine – are migraine attacks predictable?
Hoffmann, Jan; Schirra, Tonio; Lo, Hendra; Neeb, Lars; Reuter, Uwe; Martus, Peter
2015-01-01
Objective The study aimed at elucidating a potential correlation between specific meteorological variables and the prevalence and intensity of migraine attacks as well as exploring a potential individual predictability of a migraine attack based on meteorological variables and their changes. Methods Attack prevalence and intensity of 100 migraineurs were correlated with atmospheric pressure, relative air humidity, and ambient temperature in 4-h intervals over 12 consecutive months. For each correlation, meteorological parameters at the time of the migraine attack as well as their variation within the preceding 24 h were analyzed. For migraineurs showing a positive correlation, logistic regression analysis was used to assess the predictability of a migraine attack based on meteorological information. Results In a subgroup of migraineurs, a significant weather sensitivity could be observed. In contrast, pooled analysis of all patients did not reveal a significant association. An individual prediction of a migraine attack based on meteorological data was not possible, mainly as a result of the small prevalence of attacks. Interpretation The results suggest that only a subgroup of migraineurs is sensitive to specific weather conditions. Our findings may provide an explanation as to why previous studies, which commonly rely on a pooled analysis, show inconclusive results. The lack of individual attack predictability indicates that the use of preventive measures based on meteorological conditions is not feasible. PMID:25642431
Bass, Anne R; Fields, Kara G; Goto, Rie; Turissini, Gregory; Dey, Shirin; Russell, Linda A
2017-11-01
Background Clinical decision rules (CDRs) for pulmonary embolism (PE) have been validated in outpatients, but their performance in hospitalized patients is not well characterized. Objectives The goal of this systematic literature review was to assess the performance of CDRs for PE in hospitalized patients. Methods We performed a structured literature search using Medline, EMBASE and the Cochrane library for articles published on or before January 18, 2017. Two authors reviewed all titles, abstracts and full texts. We selected prospective studies of symptomatic hospitalized patients in which a CDR was used to estimate the likelihood of PE. The diagnosis of PE had to be confirmed using an accepted reference standard. Data on hospitalized patients were solicited from authors of studies in mixed populations of outpatients and hospitalized patients. Study characteristics, PE prevalence and CDR performance were extracted. The methodological quality of the studies was assessed using the QUADAS instrument. Results Twelve studies encompassing 3,942 hospitalized patients were included. Studies varied in methodology (randomized controlled trials and observational studies) and reference standards used. The pooled sensitivity of the modified Wells rule (cut-off ≤ 4) in hospitalized patients was 72.1% (95% confidence interval [CI], 63.7-79.2) and the pooled specificity was 62.2% (95% CI, 52.6-70.9). The modified Wells rule (cut-off ≤ 4) plus D-dimer testing had a pooled sensitivity 99.7% (95% CI, 96.7-100) and pooled specificity 10.8% (95% CI, 6.7-16.9). The efficiency (proportion of patients stratified into the 'PE unlikely' group) was 8.4% (95% CI, 4.1-16.5), and the failure rate (proportion of low likelihood patients who were diagnosed with PE during follow-up) was 0.1% (95% CI, 0-5.3). Conclusion In symptomatic hospitalized patients, use of the Wells rule plus D-dimer to rule out PE is safe, but allows very few patients to forgo imaging. Schattauer GmbH Stuttgart.
Herd diagnosis of low pathogen diarrhoea in growing pigs - a pilot study.
Pedersen, Ken Steen; Johansen, Markku; Angen, Oystein; Jorsal, Sven Erik; Nielsen, Jens Peter; Jensen, Tim K; Guedes, Roberto; Ståhl, Marie; Bækbo, Poul
2014-01-01
The major indication for antibiotic use in Danish pigs is treatment of intestinal diseases post weaning. Clinical decisions on antibiotic batch medication are often based on inspection of diarrhoeic pools on the pen floor. In some of these treated diarrhoea outbreaks, intestinal pathogens can only be demonstrated in a small number of pigs within the treated group (low pathogen diarrhoea). Termination of antibiotic batch medication in herds suffering from such diarrhoea could potentially reduce the consumption of antibiotics in the pig industry. The objective of the present pilot study was to suggest criteria for herd diagnosis of low pathogen diarrhoea in growing pigs. Data previously collected from 20 Danish herds were used to create a case series of clinical diarrhoea outbreaks normally subjected to antibiotic treatment. In the present study, these diarrhoea outbreaks were classified as low pathogen (<15% of the pigs having bacterial intestinal disease) (n =5 outbreaks) or high pathogen (≥15% of the pigs having bacterial intestinal disease) (n =15 outbreaks). Based on the case series, different diagnostic procedures were explored, and criteria for herd diagnosis of low pathogen diarrhoea were suggested. The effect of sampling variation was explored by simulation. The diagnostic procedure with the highest combined herd-level sensitivity and specificity was qPCR testing of a pooled sample containing 20 randomly selected faecal samples. The criteria for a positive test result (high pathogen diarrhoea outbreak) were an average of 1.5 diarrhoeic faecal pools on the floor of each pen in the room under investigation and a pathogenic bacterial load ≥35,000 per gram in the faecal pool tested by qPCR. The bacterial load was the sum of Lawsonia intracellularis, Brachyspira pilosicoli and Escherichia coli F4 and F18 bacteria per gram faeces. The herd-diagnostic performance was (herd-level) diagnostic sensitivity =0.99, diagnostic specificity =0.80, positive predictive value =0.94 and negative predictive value =0.96. The pilot study suggests criteria for herd diagnosis of low pathogen diarrhoea in growing pigs. The suggested criteria should now be evaluated, and the effect of terminating antibiotic batch medication in herds identified as suffering from low pathogen diarrhoea should be explored.
Luo, Mingxu; Song, Hongmei; Liu, Gang; Lin, Yikai; Luo, Lintao; Zhou, Xin; Chen, Bo
2017-01-01
The diagnostic values of diffusion weighted imaging (DWI) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) for N-staging of gastric cancer (GC) were identified and compared. After a systematic search to identify relevant articles, meta-analysis was used to summarize the sensitivities, specificities, and areas under curves (AUCs) for DWI and PET/CT. To better understand the diagnostic utility of DWI and PET/CT for N-staging, the performance of multi-detector computed tomography (MDCT) was used as a reference. Fifteen studies were analyzed. The pooled sensitivity, specificity, and AUC with 95% confidence intervals of DWI were 0.79 (0.73–0.85), 0.69 (0.61–0.77), and 0.81 (0.77–0.84), respectively. For PET/CT, the corresponding values were 0.52 (0.39–0.64), 0.88 (0.61–0.97), and 0.66 (0.62–0.70), respectively. Comparison of the two techniques revealed DWI had higher sensitivity and AUC, but no difference in specificity. DWI exhibited higher sensitivity but lower specificity than MDCT, and 18F-FDG PET/CT had lower sensitivity and equivalent specificity. Overall, DWI performed better than 18F-FDG PET/CT for preoperative N-staging in GC. When the efficacy of MDCT was taken as a reference, DWI represented a complementary imaging technique, while 18F-FDG PET/CT had limited utility for preoperative N-staging. PMID:29137440
Poole-frenkel piezoconductive element and sensor
Habermehl, Scott D.
2004-08-03
A new class of highly sensitive piezoconductive strain sensor elements and sensors has been invented. The new elements function under conditions such that electrical conductivity is dominated by Poole-Frenkel transport. A substantial piezoconductive effect appears in this regime, allowing the new sensors to exhibit sensitivity to applied strain as much as two orders of magnitude in excess of prior art sensors based on doped silicon.
Brault, Aaron C.; Fang, Ying; Reisen, William K.
2015-01-01
Following the introduction of West Nile virus into California during the summer of 2003, public health and vector control programs expanded surveillance efforts and were in need of diagnostics capable of rapid, sensitive, and specific detection of arbovirus infections of mosquitoes to inform decision support for intervention. Development of a multiplex TaqMan or real-time semiquantitative reverse transcription polymerase chain reaction (RT-PCR) assay in which three virus specific primer–probe sets were used in the same reaction is described herein for the detection of western equine encephalomyelitis, St. Louis encephalitis and West Nile viral RNA. Laboratory validation and field data from 10 transmission seasons are reported. The comparative sensitivity and specificity of this multiplex assay to singleplex RT-PCR as well as an antigen detection (rapid analyte measurement platform) and standard plaque assays indicate this assay to be rapid and useful in providing mosquito infection data to estimate outbreak risk. PMID:26334826
Abu Aboud, Omran A; Adaska, John M; Williams, Deniece R; Rossitto, Paul V; Champagne, John D; Lehenbauer, Terry W; Atwill, Robert; Li, Xunde; Aly, Sharif S
2016-01-01
The primary objective of this cross-sectional study was to estimate the crude, seasonal and cull-reason stratified prevalence of Salmonella fecal shedding in cull dairy cattle on seven California dairies. A secondary objective was to estimate and compare the relative sensitivity (Se) and specificity (Sp) for pools of 5 and 10 enriched broth cultures of fecal samples for Salmonella sp. detection. Seven dairy farms located in the San Joaquin Valley of California were identified and enrolled in the study as a convenience sample. Cull cows were identified for fecal sampling once during each season between 2014 and 2015, specifically during spring, summer, fall, and winter, and 10 cows were randomly selected for fecal sampling at the day of their sale. In addition, study personnel completed a survey based on responses of the herd manager to questions related to the previous four month's herd management. Fecal samples were frozen until testing for Salmonella. After overnight enrichment in liquid broth, pools of enrichment broth (EBP) were created for 5 and 10 samples. All individual and pooled broths were cultured on selective media with putative Salmonella colonies confirmed by biochemical testing before being serogrouped and serotyped. A total of 249 cull cows were enrolled into the study and their fecal samples tested for Salmonella. The survey-weighted period prevalence of fecal shedding of all Salmonella sp. in the cull cow samples across all study herds and the entire study period was 3.42% (N = 249; SE 1.07). The within herd prevalence of Salmonella shed in feces did not differ over the four study seasons (P = 0.074). The Se of culture of EBP of five samples was 62.5% (SE = 17.12), which was not statistically different from the Se of culture of EBP of 10 (37.5%, SE = 17.12, P = 0.48). The Sp of culture of EBP of five samples was 95.24% (SE = 3.29) and for pools of 10 samples was 100.00% (SE = 0). There was no statistical difference between the culture relative specificities of EBP of 5 and 10 (P > 0.99). Our study showed a numerically higher prevalence of Salmonella shedding in the summer, although the results were not significant, most likely due to a lack of power from the small sample size. A higher prevalence in summer months may be related to heat stress. To detect Salmonella, investigators may expect a 62.5% sensitivity for culture of EBP of five, relative to individual fecal sample enrichment and culture. In contrast, culture of EBP of 10 samples resulted in a numerically lower Se. Culture of EBP of size 5 or 10 samples, given similar prevalence and limit of detection, can be expected to yield specificities of 95 and 100%, respectively.
Abu Aboud, Omran A.; Adaska, John M.; Williams, Deniece R.; Rossitto, Paul V.; Champagne, John D.; Lehenbauer, Terry W.; Atwill, Robert; Li, Xunde
2016-01-01
Background The primary objective of this cross-sectional study was to estimate the crude, seasonal and cull-reason stratified prevalence of Salmonella fecal shedding in cull dairy cattle on seven California dairies. A secondary objective was to estimate and compare the relative sensitivity (Se) and specificity (Sp) for pools of 5 and 10 enriched broth cultures of fecal samples for Salmonella sp. detection. Methods Seven dairy farms located in the San Joaquin Valley of California were identified and enrolled in the study as a convenience sample. Cull cows were identified for fecal sampling once during each season between 2014 and 2015, specifically during spring, summer, fall, and winter, and 10 cows were randomly selected for fecal sampling at the day of their sale. In addition, study personnel completed a survey based on responses of the herd manager to questions related to the previous four month’s herd management. Fecal samples were frozen until testing for Salmonella. After overnight enrichment in liquid broth, pools of enrichment broth (EBP) were created for 5 and 10 samples. All individual and pooled broths were cultured on selective media with putative Salmonella colonies confirmed by biochemical testing before being serogrouped and serotyped. Results A total of 249 cull cows were enrolled into the study and their fecal samples tested for Salmonella. The survey-weighted period prevalence of fecal shedding of all Salmonella sp. in the cull cow samples across all study herds and the entire study period was 3.42% (N = 249; SE 1.07). The within herd prevalence of Salmonella shed in feces did not differ over the four study seasons (P = 0.074). The Se of culture of EBP of five samples was 62.5% (SE = 17.12), which was not statistically different from the Se of culture of EBP of 10 (37.5%, SE = 17.12, P = 0.48). The Sp of culture of EBP of five samples was 95.24% (SE = 3.29) and for pools of 10 samples was 100.00% (SE = 0). There was no statistical difference between the culture relative specificities of EBP of 5 and 10 (P > 0.99). Discussion Our study showed a numerically higher prevalence of Salmonella shedding in the summer, although the results were not significant, most likely due to a lack of power from the small sample size. A higher prevalence in summer months may be related to heat stress. To detect Salmonella, investigators may expect a 62.5% sensitivity for culture of EBP of five, relative to individual fecal sample enrichment and culture. In contrast, culture of EBP of 10 samples resulted in a numerically lower Se. Culture of EBP of size 5 or 10 samples, given similar prevalence and limit of detection, can be expected to yield specificities of 95 and 100%, respectively. PMID:27635350
Diagnostic accuracy of physical examination for anterior knee instability: a systematic review.
Leblanc, Marie-Claude; Kowalczuk, Marcin; Andruszkiewicz, Nicole; Simunovic, Nicole; Farrokhyar, Forough; Turnbull, Travis Lee; Debski, Richard E; Ayeni, Olufemi R
2015-10-01
Determining diagnostic accuracy of Lachman, pivot shift and anterior drawer tests versus gold standard diagnosis (magnetic resonance imaging or arthroscopy) for anterior cruciate ligament (ACL) insufficiency cases. Secondarily, evaluating effects of: chronicity, partial rupture, awake versus anaesthetized evaluation. Searching MEDLINE, EMBASE and PubMed identified studies on diagnostic accuracy for ACL insufficiency. Studies identification and data extraction were performed in duplicate. Quality assessment used QUADAS tool, and statistical analyses were completed for pooled sensitivity and specificity. Eight studies were included. Given insufficient data, pooled analysis was only possible for sensitivity on Lachman and pivot shift test. During awake evaluation, sensitivity for the Lachman test was 89 % (95 % CI 0.76, 0.98) for all rupture types, 96 % (95 % CI 0.90, 1.00) for complete ruptures and 68 % (95 % CI 0.25, 0.98) for partial ruptures. For pivot shift in awake evaluation, results were 79 % (95 % CI 0.63, 0.91) for all rupture types, 86 % (95 % CI 0.68, 0.99) for complete ruptures and 67 % (95 % CI 0.47, 0.83) for partial ruptures. Decreased sensitivity of Lachman and pivot shift tests for partial rupture cases and for awake patients raised suspicions regarding the accuracy of these tests for diagnosis of ACL insufficiency. This may lead to further research aiming to improve the understanding of the true accuracy of these physical diagnostic tests and increase the reliability of clinical investigation for this pathology. IV.
A Survey of Validation Strategies for CRISPR-Cas9 Editing.
Sentmanat, Monica F; Peters, Samuel T; Florian, Colin P; Connelly, Jon P; Pruett-Miller, Shondra M
2018-01-17
The T7 endonuclease 1 (T7E1) mismatch detection assay is a widely used method for evaluating the activity of site-specific nucleases, such as the clustered regularly interspaced short palindromic repeats (CRISPR)-Cas9 system. To determine the accuracy and sensitivity of this assay, we compared the editing estimates derived by the T7E1 assay with that of targeted next-generation sequencing (NGS) in pools of edited mammalian cells. Here, we report that estimates of nuclease activity determined by T7E1 most often do not accurately reflect the activity observed in edited cells. Editing efficiencies of CRISPR-Cas9 complexes with similar activity by T7E1 can prove dramatically different by NGS. Additionally, we compared editing efficiencies predicted by the Tracking of Indels by Decomposition (TIDE) assay and the Indel Detection by Amplicon Analysis (IDAA) assay to that observed by targeted NGS for both cellular pools and single-cell derived clones. We show that targeted NGS, TIDE, and IDAA assays predict similar editing efficiencies for pools of cells but that TIDE and IDAA can miscall alleles in edited clones.
Cargnin, Sarah; Jommi, Claudio; Canonico, Pier Luigi; Genazzani, Armando A; Terrazzino, Salvatore
2014-05-01
To determine diagnostic accuracy of HLA-B*57:01 testing for prediction of abacavir-induced hypersensitivity and to quantify the clinical benefit of pretreatment screening through a meta-analytic review of published studies. A comprehensive search was performed up to June 2013. The methodological quality of relevant studies was assessed by the QUADAS-2 tool. The pooled diagnostic estimates were calculated using a random effect model. Despite the presence of heterogeneity in sensitivity or specificity estimates, the pooled diagnostic odds ratio to detect abacavir-induced hypersensitivity on the basis of clinical criteria was 33.07 (95% CI: 22.33-48.97, I(2): 13.9%), while diagnostic odds ratio for detection of immunologically confirmed abacavir hypersensitivity was 1141 (95% CI: 409-3181, I(2): 0%). Pooled analysis of risk ratio showed that prospective HLA-B*57:01 testing significantly reduced the incidence of abacavir-induced hypersensitivity. This meta-analysis demonstrates an excellent diagnostic accuracy of HLA-B*57:01 testing to detect immunologically confirmed abacavir hypersensitivity and corroborates existing recommendations.
Vasseur, Corinne; Domingues-Hamdi, Elisa; Ledudal, Katia; Le Corvoisier, Philippe; Barau, Caroline; Ghaleh, Bijan; Rialland, Amandine; Pissard, Serge; Galactéros, Frédéric; Baudin-Creuza, Véronique
2017-10-01
The severity of β-thalassaemia (β-thal) intermedia is mainly correlated to the degree of imbalanced α/non α-globin chain synthesis. The phenotypic diversity of β-thal depends on this imbalance and reflects all possible combinations of α- and β-globin genotypes, levels of fetal haemoglobin (HbF) and co-inheritance of other modulating factors. This study aimed to demonstrate the validity of a new surrogate of α/non α-globin biosynthetic ratio by measuring the soluble α-Hb pool in lysed red blood cells. Our results confirm that the α-Hb pool measurement allows a good discrimination between β-thal intermedia patients, controls and α-thal patients (P < 0·003). Receiver operator characteristic analyses revealed an area under the curve of 0·978 for the α-Hb pool measurement at a threshold of 120 ng free α-Hb/mg of total Hb/ml of haemolysate (ppm) with a sensitivity and specificity of 86% and 100%, respectively, to discriminate between β-thal and not β-thal subjects. Significant correlations were observed between the α-Hb pool and biological parameters of β-thal, the most significant association being observed with red cell hexokinase activity. This study indicates that the α-Hb pool could be a new marker for assistance in diagnostic orientation of β-thal intermedia patients and may be clinically useful for monitoring the evolution of the disequilibrium of globin synthesis in response to treatments. © 2017 John Wiley & Sons Ltd.
Alduraywish, S A; Lodge, C J; Campbell, B; Allen, K J; Erbas, B; Lowe, A J; Dharmage, S C
2016-01-01
There is growing evidence for an increase in food allergies. The question of whether early life food sensitization, a primary step in food allergies, leads to other allergic disease is a controversial but important issue. Birth cohorts are an ideal design to answer this question. We aimed to systematically investigate and meta-analyse the evidence for associations between early food sensitization and allergic disease in birth cohorts. MEDLINE and SCOPUS databases were searched for birth cohorts that have investigated the association between food sensitization in the first 2 years and subsequent wheeze/asthma, eczema and/or allergic rhinitis. We performed meta-analyses using random-effects models to obtain pooled estimates, stratified by age group. The search yielded fifteen original articles representing thirteen cohorts. Early life food sensitization was associated with an increased risk of infantile eczema, childhood wheeze/asthma, eczema and allergic rhinitis and young adult asthma. Meta-analyses demonstrated that early life food sensitization is related to an increased risk of wheeze/asthma (pooled OR 2.9; 95% CI 2.0-4.0), eczema (pooled OR 2.7; 95% CI 1.7-4.4) and allergic rhinitis (pooled OR 3.1; 95% CI 1.9-4.9) from 4 to 8 years. Food sensitization in the first 2 years of life can identify children at high risk of subsequent allergic disease who may benefit from early life preventive strategies. However, due to potential residual confounding in the majority of studies combined with lack of follow-up into adolescence and adulthood, further research is needed. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Sun, Changling; Zhang, Yayun; Han, Xue; Du, Xiaodong
2018-03-01
Objective The purposes of this study were to verify the effectiveness of the narrow band imaging (NBI) system in diagnosing nasopharyngeal cancer (NPC) as compared with white light endoscopy. Data Sources PubMed, Cochrane Library, EMBASE, CNKI, and Wan Fang databases. Review Methods Data analyses were performed with Meta-Disc. The updated Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess study quality and potential bias. Publication bias was assessed with a Deeks asymmetry test. The registry number of the protocol published on PROSPERO is CRD42015026244. Results This meta-analysis included 10 studies of 1337 lesions. For NBI diagnosis of NPC, the pooled values were as follows: sensitivity, 0.83 (95% CI, 0.80-0.86); specificity, 0.91 (95% CI, 0.89-0.93); positive likelihood ratio, 8.82 (95% CI, 5.12-15.21); negative likelihood ratio, 0.18 (95% CI, 0.12-0.27); and diagnostic odds ratio, 65.73 (95% CI, 36.74-117.60). The area under the curve was 0.9549. For white light endoscopy in diagnosing NPC, the pooled values were as follows: sensitivity, 0.79 (95% CI, 0.75-0.83); specificity, 0.87 (95% CI, 0.84-0.90); positive likelihood ratio, 5.02 (95% CI, 1.99-12.65); negative likelihood ratio, 0.34 (95% CI, 0.24-0.49); and diagnostic odds ratio, 16.89 (95% CI, 5.98-47.66). The area under the curve was 0.8627. The evaluation of heterogeneity, calculated per the diagnostic odds ratio, gave an I 2 of 0.326. No marked publication bias ( P = .68) existed in this meta-analysis. Conclusion The sensitivity and specificity of NBI for the diagnosis of NPC are similar to those of white light endoscopy, and the potential value of NBI for the diagnosis of NPC needs to be validated further.
Hu, Guimei; Qin, Lijun; Zhang, Xinjun; Ye, Guoliang; Huang, Tao
2018-01-01
Human mutL homolog 1 (MLH1) promoter methylation was reported in gastric cancer (GC). This study determined the clinicopathological, prognostic, and diagnostic effects of MLH1 promoter methylation in GC. The combined odds ratio (OR) or hazard ratio (HR) and their corresponding 95% confidence intervals (95% CI) were calculated. The pooled sensitivity, specificity, and area under the curve (AUC) were analyzed. A total of 4654 GC patients and 3669 non-malignant controls were identified in this systematic analysis. MLH1 promoter methylation was significantly higher in GC samples than in gastric adenomas, chronic gastritis, adjacent tissues, normal gastric mucosa, and normal healthy blood samples, but it exhibited a similar frequency in GC vs. intestinal metaplasia and dysplasia samples. MLH1 promoter methylation correlated with age and microsatellite instability (MSI), but it was not associated with gender, H. pylori infection, smoking, drinking behaviors, pathological histology, tumor differentiation, clinical stage, lymph node status, distant metastasis, or overall survival of GC. MLH1 promoter methylation exhibited a poor sensitivity value (< 0.5) in patients with GC compared with adjacent tissues, gastric adenomas, chronic gastritis, normal gastric mucosa, and normal healthy blood samples. The pooled sensitivity, specificity, and AUC of MLH1 promoter methylation in GC with MSI vs. GC with microsatellite stability (MSS) samples were 0.64, 0.96, and 0.90, respectively. Our results suggest that the detection of MLH1 promoter methylation may be a potential prognostic biomarker for GC patients with MSI. © 2018 The Author(s). Published by S. Karger AG, Basel.
Kumar, Gyanendra; Shahripour, Reza Bavarsad; Harrigan, Mark R
2016-05-01
OBJECT The impact of transcranial Doppler (TCD) ultrasonography evidence of vasospasm on patient-centered clinical outcomes following aneurysmal subarachnoid hemorrhage (aSAH) is unknown. Vasospasm is known to lead to delayed cerebral ischemia (DCI) and poor outcomes. This systematic review and meta-analysis evaluates the predictive value of vasospasm on DCI, as diagnosed on TCD. METHODS MEDLINE, Scopus, the Cochrane trial register, and clinicaltrials.gov were searched through September 2014 using key words and the terms "subarachnoid hemorrhage," "aneurysm," "aneurysmal," "cerebral vasospasm," "vasospasm," "transcranial Doppler," and "TCD." Sensitivities, specificities, and positive and negative predictive values were pooled by a DerSimonian and Laird random-effects model. RESULTS Seventeen studies (n = 2870 patients) met inclusion criteria. The amount of variance attributable to heterogeneity was significant (I(2) > 50%) for all syntheses. No studies reported the impact of TCD evidence of vasospasm on functional outcome or mortality. TCD evidence of vasospasm was found to be highly predictive of DCI. Pooled estimates for TCD diagnosis of vasospasm (for DCI) were sensitivity 90% (95% confidence interval [CI] 77%-96%), specificity 71% (95% CI 51%-84%), positive predictive value 57% (95% CI 38%-71%), and negative predictive value 92% (95% CI 83%-96%). CONCLUSIONS TCD evidence of vasospasm is predictive of DCI with high accuracy. Although high sensitivity and negative predictive value make TCD an ideal monitoring device, it is not a mandated standard of care in aSAH due to the paucity of evidence on clinically relevant outcomes, despite recommendation by national guidelines. High-quality randomized trials evaluating the impact of TCD monitoring on patient-centered and physician-relevant outcomes are needed.
Dong, Fan; Shen, Yifan; Xu, Tianyuan; Wang, Xianjin; Gao, Fengbin; Zhong, Shan; Chen, Shanwen; Shen, Zhoujun
2018-03-21
Previous researches pointed out that the measurement of urine fibronectin (Fn) could be a potential diagnostic test for bladder cancer (BCa). We conducted this meta-analysis to fully assess the diagnostic value of urine Fn for BCa detection. A systematic literature search in PubMed, ISI Web of Science, EMBASE, Cochrane library, and CBM was carried out to identify eligible studies evaluating the urine Fn in diagnosing BCa. Pooled sensitivity, specificity, and diagnostic odds ratio (DOR) with their 95% confidence intervals (CIs) were calculated, and summary receiver operating characteristic (SROC) curves were established. We applied the STATA 13.0, Meta-Disc 1.4, and RevMan 5.3 software to the meta-analysis. Eight separate studies with 744 bladder cancer patients were enrolled in this meta-analysis. The pooled sensitivity, specificity, and DOR were 0.80 (95%CI = 0.77-0.83), 0.79 (95%CI = 0.73-0.84), and 15.18 (95%CI = 10.07-22.87), respectively, and the area under the curve (AUC) of SROC was 0.83 (95%CI = 0.79-0.86). The diagnostic power of a combined method (urine Fn combined with urine cytology) was also evaluated, and its sensitivity and AUC were significantly higher (0.86 (95%CI = 0.82-0.90) and 0.89 (95%CI = 0.86-0.92), respectively). Meta-regression along with subgroup analysis based on various covariates revealed the potential sources of the heterogeneity and the detailed diagnostic value of each subgroup. Sensitivity analysis supported that the result was robust. No threshold effect and publication bias were found in this meta-analysis. Urine Fn may become a promising non-invasive biomarker for bladder cancer with a relatively satisfactory diagnostic power. And the combination of urine Fn with cytology could be an alternative option for detecting BCa in clinical practice. The potential value of urine Fn still needs to be validated in large, multi-center, and prospective studies.
Biedermann, J S; van den Besselaar, A M H P; de Maat, M P M; Leebeek, F W G; Kruip, M J H A
2017-03-01
Essentials Differences in sensitivity to factor VII (FVII) have been suggested between thromboplastins. FVII-induced International Normalized Ratio (INR) changes differ between commercial reagents. Recombinant human thromboplastins are more sensitive to FVII than tissue-extract thromboplastins. Thromboplastin choice may affect FVII-mediated INR stability. Background Differences regarding sensitivity to factor VII have been suggested for recombinant human and tissue-extract thromboplastins used for International Normalized Ratio (INR) measurement, but the evidence is scarce. Differences in FVII sensitivity are clinically relevant, as they can affect INR stability during treatment with vitamin K antagonists (VKAs). Objectives To determine whether commercial thromboplastins react differently to changes in FVII. Methods We studied the effect of addition of FVII on the INR in plasma by using three tissue-extract (Neoplastin C1+, Hepato Quick, and Thromborel S) and three recombinant human (Recombiplastin 2G, Innovin, and CoaguChek XS) thromboplastins. Three different concentrations of purified human FVII (0.006, 0.012 and 0.062 μg mL -1 plasma), or buffer, were added to five certified pooled plasmas of patients using VKAs (INR of 1.5-3.5). Changes in FVII activity were measured with two bioassays (Neoplastin and Recombiplastin), and relative INR changes were compared between reagents. Results After addition of 0.062 μg mL -1 FVII, FVII activity in the pooled plasmas increased by approximately 20% (Neoplastin) or 32% (Recombiplastin) relative to the activity in pooled normal plasma. All thromboplastins showed dose-dependent INR decreases. The relative INR change in the pooled plasmas significantly differed between the six thromboplastins. No differences were observed among recombinant or tissue-extract thromboplastins. Pooled results indicated that the FVII-induced INR change was greater for recombinant than for tissue-extract thromboplastins. Conclusions Differences regarding FVII sensitivity exist between various thromboplastins used for VKA monitoring. Recombinant human thromboplastins are more sensitive to FVII than tissue-extract thromboplastins. Therefore, thromboplastin choice may affect FVII-mediated INR stability. © 2017 International Society on Thrombosis and Haemostasis.
Westwood, Marie E; Raatz, Heike D I; Misso, Kate; Burgers, Laura; Redekop, Ken; Lhachimi, Stefan K; Armstrong, Nigel; Kleijnen, Jos
2013-05-01
To assess the diagnostic performance of dual-source cardiac (DSC) computed tomography (CT) newer-generation CT instruments for identifying anatomically significant coronary artery disease (CAD) in patients who are difficult to image by using 64-section CT. A literature search comprised bibliographic databases (January 1, 2000, to March 22, 2011, with a pragmatic update on September 6, 2012), trial registries, and conference proceedings. Only studies using invasive coronary angiography as reference standard were included. Risk of bias was assessed (QUADAS-2). Results were stratified according to patient group on the basis of clinical characteristics. Summary estimates of sensitivity and specificity of DSC CT for detecting 50% or greater arterial stenosis were calculated by using a bivariate summary receiver operating characteristic or random-effects model. Twenty-five studies reported accuracy of DSC CT for diagnosing CAD in difficult to image patients; in 22 studies, one of two CT units of the same manufacturer (Somatom Definition or Somatom Definition Flash) was used, and in the remaining three, a different CT unit of another manufacturer (Aquilion One) was used. The pooled, per-patient estimates of sensitivity were 97.7% (95% confidence interval [CI]: 88.0%, 99.9%) and 97.7% (95% CI: 93.2%, 99.3%) for patients with arrhythmias and high heart rates, respectively. The corresponding pooled estimates of specificity were 81.7% (95% CI: 71.6%, 89.4%) and 86.3% (95% CI: 80.2%, 90.7%), respectively. All data were acquired by using Somatom Definition. In two studies with Somatom and one study with Aquilion One, sensitivity estimates of 90% or greater were reported in patients with previous stent implantations; specificities were 81.7% and 89.5% for Somatom and 81.0% for Aquilion One. In patients with high coronary calcium scores, previous bypass grafts, or obesity, only per-segment or per-artery data were available. Sensitivity estimates remained high (>90% in all but one study), and specificities ranged from 79.1% to 100%. All data were acquired by using Somatom Definition. DSC CT may be sufficiently accurate to diagnose clinically significant CAD in some or all difficult to image patients. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13121136/-/DC1. © RSNA, 2013.
Combescure, Christophe; Fokom-Defo, Victoire; Tebeu, Pierre Marie; Vassilakos, Pierre; Kengne, André Pascal; Petignat, Patrick
2015-01-01
Objective To assess and compare the accuracy of visual inspection with acetic acid (VIA), visual inspection with Lugol’s iodine (VILI), and human papillomavirus (HPV) testing as alternative standalone methods for primary cervical cancer screening in sub-Saharan Africa. Design Systematic review and meta-analysis of diagnostic test accuracy studies. Data sources Systematic searches of multiple databases including Medline, Embase, and Scopus for studies published between January 1994 and June 2014. Review methods Inclusion criteria for studies were: alternative methods to cytology used as a standalone test for primary screening; study population not at particular risk of cervical cancer (excluding studies focusing on HIV positive women or women with gynaecological symptoms); women screened by nurses; reference test (colposcopy and directed biopsies) performed at least in women with positive screening results. Two reviewers independently screened studies for eligibility and extracted data for inclusion, and evaluated study quality using the quality assessment of diagnostic accuracy studies 2 (QUADAS-2) checklist. Primary outcomes were absolute accuracy measures (sensitivity and specificity) of screening tests to detect cervical intraepithelial neoplasia grade 2 or worse (CIN2+). Results 15 studies of moderate quality were included (n=61 381 for VIA, n=46 435 for VILI, n=11 322 for HPV testing). Prevalence of CIN2+ did not vary by screening test and ranged from 2.3% (95% confidence interval 1.5% to 3.3%) in VILI studies to 4.9% (2.7% to 7.8%) in HPV testing studies. Positivity rates of VILI, VIA, and HPV testing were 16.5% (9.8% to 24.7%), 16.8% (11.0% to 23.6%), and 25.8% (17.4% to 35.3%), respectively. Pooled sensitivity was higher for VILI (95.1%; 90.1% to 97.7%) than VIA (82.4%; 76.3% to 87.3%) in studies where the reference test was performed in all women (P<0.001). Pooled specificity of VILI and VIA were similar (87.2% (78.1% to 92.8%) v 87.4% (77.1% to 93.4%); P=0.85). Pooled sensitivity and specificity were similar for HPV testing versus VIA (both P≥0.23) and versus VILI (both P≥0.16). Accuracy of VIA and VILI increased with sample size and time period. Conclusions For primary screening of cervical cancer in sub-Saharan Africa, VILI is a simple and affordable alternative to cytology that demonstrates higher sensitivity than VIA. Implementation studies are needed to assess the effect of these screening strategies on the incidence and outcomes of cervical cancer in the region. PMID:26142020
Processing of color signals in female carriers of color vision deficiency.
Konstantakopoulou, Evgenia; Rodriguez-Carmona, Marisa; Barbur, John L
2012-02-14
The aim of this study was to assess the chromatic sensitivity of carriers of color deficiency, specifically in relation to dependence on retinal illuminance, and to reference these findings to the corresponding red-green (RG) thresholds measured in normal trichromatic males. Thirty-six carriers of congenital RG color deficiency and 26 normal trichromatic males participated in the study. The retinal illuminance was estimated by measuring the pupil diameter and the optical density of the lens and the macular pigment. Each subject's color vision was examined using the Color Assessment and Diagnosis (CAD) test, the Ishihara and American Optical pseudoisochromatic plates, and the Nagel anomaloscope. Carriers of deuteranopia (D) and deuteranomaly (DA) had higher RG thresholds than male trichromats (p < 0.05). When referenced to male trichromats, carriers of protanomaly (PA) needed 28% less color signal strength; carriers of D required ∼60% higher thresholds at mesopic light levels. Variation in the L:M ratio and hence the absolute M-cone density may be the principal factor underlying the poorer chromatic sensitivity of D carriers in the low photopic range. The increased sensitivity of PA carriers at lower light levels is consistent with the pooling of signals from the hybrid M' and the M cones and the subsequent stronger inhibition of the rods. The findings suggest that signals from hybrid photopigments may pool preferentially with the spectrally closest "normal" pigments.
Gibson, Barry J; Paul, Ninu R
2014-01-01
This article seeks to unpack the relationship between social structure and accounts of illness. Taking dentine hypersensitivity as an example, this article explores the perspective that accounts of illness are sense-making processes that draw on a readily available pool of meaning. This pool of meaning is composed of a series of distinctions that make available a range of different lines of communication and action about such conditions. Such lines of communication are condensed and preserved over time and are often formed around a concept and its counter concept. The study of such processes is referred to as semantic analysis and involves drawing on the tools and techniques of conceptual history. This article goes on to explore how the semantics of dentine hypersensitivity developed. It illustrates how processes of social differentiation led to the concept being separated from the more dominant concept of dentine sensitivity and how it was medicalised, scientised and economised. In short, this study seeks to present the story of how society has developed a specific language for communicating about sensitivity and hypersensitivity in teeth. In doing so, it proposes that accounts of dentine hypersensitivity draw on lines of communication that society has preserved over time. PMID:25197262
de Ruiter, C. M.; van der Veer, C.; Leeflang, M. M. G.; Deborggraeve, S.; Lucas, C.
2014-01-01
Molecular methods have been proposed as highly sensitive tools for the detection of Leishmania parasites in visceral leishmaniasis (VL) patients. Here, we evaluate the diagnostic accuracy of these tools in a meta-analysis of the published literature. The selection criteria were original studies that evaluate the sensitivities and specificities of molecular tests for diagnosis of VL, adequate classification of study participants, and the absolute numbers of true positives and negatives derivable from the data presented. Forty studies met the selection criteria, including PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA), and loop-mediated isothermal amplification (LAMP). The sensitivities of the individual studies ranged from 29 to 100%, and the specificities ranged from 25 to 100%. The pooled sensitivity of PCR in whole blood was 93.1% (95% confidence interval [CI], 90.0 to 95.2), and the specificity was 95.6% (95% CI, 87.0 to 98.6). The specificity was significantly lower in consecutive studies, at 63.3% (95% CI, 53.9 to 71.8), due either to true-positive patients not being identified by parasitological methods or to the number of asymptomatic carriers in areas of endemicity. PCR for patients with HIV-VL coinfection showed high diagnostic accuracy in buffy coat and bone marrow, ranging from 93.1 to 96.9%. Molecular tools are highly sensitive assays for Leishmania detection and may contribute as an additional test in the algorithm, together with a clear clinical case definition. We observed wide variety in reference standards and study designs and now recommend consecutively designed studies. PMID:24829226
Kedia, Saurabh; Sharma, Raju; Sreenivas, Vishnubhatla; Madhusudhan, Kumble Seetharama; Sharma, Vishal; Bopanna, Sawan; Pratap Mouli, Venigalla; Dhingra, Rajan; Yadav, Dawesh Prakash; Makharia, Govind; Ahuja, Vineet
2017-04-01
Abdominal computed tomography (CT) can noninvasively image the entire gastrointestinal tract and assess extraintestinal features that are important in differentiating Crohn's disease (CD) and intestinal tuberculosis (ITB). The present meta-analysis pooled the results of all studies on the role of CT abdomen in differentiating between CD and ITB. We searched PubMed and Embase for all publications in English that analyzed the features differentiating between CD and ITB on abdominal CT. The features included comb sign, necrotic lymph nodes, asymmetric bowel wall thickening, skip lesions, fibrofatty proliferation, mural stratification, ileocaecal area, long segment, and left colonic involvements. Sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratio (DOR) were calculated for all the features. Symmetric receiver operating characteristic curve was plotted for features present in >3 studies. Heterogeneity and publication bias was assessed and sensitivity analysis was performed by excluding studies that compared features on conventional abdominal CT instead of CT enterography (CTE). We included 6 studies (4 CTE, 1 conventional abdominal CT, and 1 CTE+conventional abdominal CT) involving 417 and 195 patients with CD and ITB, respectively. Necrotic lymph nodes had the highest diagnostic accuracy (sensitivity, 23%; specificity, 100%; DOR, 30.2) for ITB diagnosis, and comb sign (sensitivity, 82%; specificity, 81%; DOR, 21.5) followed by skip lesions (sensitivity, 86%; specificity, 74%; DOR, 16.5) had the highest diagnostic accuracy for CD diagnosis. On sensitivity analysis, the diagnostic accuracy of other features excluding asymmetric bowel wall thickening remained similar. Necrotic lymph nodes and comb sign on abdominal CT had the best diagnostic accuracy in differentiating CD and ITB.
A preamplification approach to GMO detection in processed foods.
Del Gaudio, S; Cirillo, A; Di Bernardo, G; Galderisi, U; Cipollaro, M
2010-03-01
DNA is widely used as a target for GMO analysis because of its stability and high detectability. Real-time PCR is the method routinely used in most analytical laboratories due to its quantitative performance and great sensitivity. Accurate DNA detection and quantification is dependent on the specificity and sensitivity of the amplification protocol as well as on the quality and quantity of the DNA used in the PCR reaction. In order to enhance the sensitivity of real-time PCR and consequently expand the number of analyzable target genes, we applied a preamplification technique to processed foods where DNA can be present in low amounts and/or in degraded forms thereby affecting the reliability of qualitative and quantitative results. The preamplification procedure utilizes a pool of primers targeting genes of interest and is followed by real-time PCR reactions specific for each gene. An improvement of Ct values was found comparing preamplified vs. non-preamplified DNA. The strategy reported in the present study will be also applicable to other fields requiring quantitative DNA testing by real-time PCR.
Galvin, Rose; Gilleit, Yannick; Wallace, Emma; Cousins, Gráinne; Bolmer, Manon; Rainer, Timothy; Smith, Susan M; Fahey, Tom
2017-03-01
older adults are frequent users of emergency services and demonstrate high rates of adverse outcomes following emergency care. to perform a systematic review and meta-analysis of the Identification of Seniors At Risk (ISAR) screening tool, to determine its predictive value in identifying adults ≥65 years at risk of functional decline, unplanned emergency department (ED) readmission, emergency hospitalisation or death within 180 days after index ED visit/hospitalisation. a systematic literature search was conducted in PubMed, EMBASE, CINAHL, EBSCO and the Cochrane Library to identify validation and impact analysis studies of the ISAR tool. A pre-specified ISAR score of ≥2 (maximum score 6 points) was used to identify patients at high risk of adverse outcomes. A bivariate random effects model generated pooled estimates of sensitivity and specificity. Statistical heterogeneity was explored and methodological quality was assessed using validated criteria. thirty-two validation studies (n = 12,939) are included. At ≥2, the pooled sensitivity of the ISAR for predicting ED return, emergency hospitalisation and mortality at 6 months is 0.80 (95% confidence interval (CI) 0.70-0.87), 0.82 (95% CI 0.74-0.88) and 0.87 (95% CI 0.75-0.94), respectively, with a pooled specificity of 0.31 (95% CI 0.24-0.38), 0.32 (95% CI 0.24-0.41) and 0.35 (95% CI 0.26-0.44). Similar values are demonstrated at 30 and 90 days. Three heterogeneous impact analysis studies examined the clinical implementation of the ISAR and reported mixed findings across patient and process outcomes. the ISAR has modest predictive accuracy and may serve as a decision-making adjunct when determining which older adults can be safely discharged. © The Author 2016. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Ballek, Ondřej; Valečka, Jan; Manning, Jasper; Filipp, Dominik
2015-04-01
The initiation of T-cell receptor (TCR) signaling, based on the cobinding of TCR and CD4-Lck heterodimer to a peptide-major histocompatibility complex II on antigen presenting cells, represents a classical model of T-cell signaling. What is less clear however, is the mechanism which translates TCR engagement to the phosphorylation of immunoreceptor tyrosine-based activation motifs on CD3 chains and how this event is coupled to the delivery of Lck function. Recently proposed 'standby model of Lck' posits that resting T-cells contain an abundant pool of constitutively active Lck (pY394(Lck)) required for TCR triggering, and this amount, upon TCR engagement, remains constant. Here, we show that although maintenance of the limited pool of pY394(Lck) is necessary for the generation of TCR proximal signals in a time-restricted fashion, the total amount of this pool, ~2%, is much smaller than previously reported (~40%). We provide evidence that this dramatic discrepancy in the content of pY394(Lck)is likely the consequence of spontaneous phosphorylation of Lck that occurred after cell solubilization. Additional discrepancies can be accounted for by the sensitivity of different pY394(Lck)-specific antibodies and the type of detergents used. These data suggest that reagents and conditions used for the quantification of signaling parameters must be carefully validated and interpreted. Thus, the limited size of pY394(Lck) pool in primary T-cells invites a discussion regarding the adjustment of the quantitative parameters of the standby model of Lck and reevaluation of the mechanism by which this pool contributes to the generation of proximal TCR signaling.
de Larramendi, Carlos Hernando; Carnés, Jerónimo; García-Abujeta, José Luís; García-Endrino, Ana; Muñoz-Palomino, Elena; Huertas, Angel Julio; Fernández-Caldas, Enrique; Ferrer, Angel
2008-01-01
Cases of allergy to Cannabis sativa have occasionally been reported, but both the allergenic profile and eventual cross-reactivity pattern remain unknown. To analyze the allergenic profile of a population of patients from Spain sensitized to C. sativa and to characterize the C. sativa leaf extract. A total of 32 subjects were enrolled in the study: group A, 10 individuals sensitized to tomato, reporting reactions by contact or inhalation to Cannabis; group B, 14 individuals sensitized to tomato, without reactions to Cannabis; group C, 8 individuals not sensitized to tomato and without reactions to Cannabis. Sensitivity to Cannabis, tomato and peach peel, Platanus hybrida and Artemisia vulgaris pollen extracts was measured by skin tests and specific IgE. Individual immunoblots and inhibition experiments with a pool of sera were conducted. All tomato-sensitized subjects (and 1 negative) had positive skin tests to C. sativa leaves and hashish. Specific IgE to C. sativa and peach peel was more common than to tomato. Immunoblot experiments showed 2 prominent bands of 10 and 14 kDa and 2 weakly recognized bands of 30 and 45 kDa. Tomato, peach and A. vulgaris extracts inhibited most of the bands present in C. sativa. P. hybrida inhibited only the high-molecular-weight bands. Sensitization to C. sativa with or without symptoms is frequent among patients in Spain sensitized to tomato. C. sativa leaves are a potential allergenic source and their allergens may cross-react with other allergenic sources from plants (fruit peels and pollen). (c) 2008 S. Karger AG, Basel
Theron, Grant; Peter, Jonny; Richardson, Marty; Barnard, Marinus; Donegan, Sarah; Warren, Rob; Steingart, Karen R; Dheda, Keertan
2014-01-01
Background Accurate and rapid tests for tuberculosis (TB) drug resistance are critical for improving patient care and decreasing the transmission of drug-resistant TB. Genotype®MTBDRsl (MTBDRsl) is the only commercially-available molecular test for detecting resistance in TB to the fluoroquinolones (FQs; ofloxacin, moxifloxacin and levofloxacin) and the second-line injectable drugs (SLIDs; amikacin, kanamycin and capreomycin), which are used to treat patients with multidrug-resistant (MDR-)TB. Objectives To obtain summary estimates of the diagnostic accuracy ofMTBDRsl for FQ resistance, SLID resistance and extensively drug-resistant TB (XDR-TB; defined asMDR-TB plus resistance to a FQand a SLID) when performed (1) indirectly (ie on culture isolates confirmed as TB positive) and (2) directly (ie on smear-positive sputum specimens). To compare summary estimates of the diagnostic accuracy of MTBDRsl for FQ resistance, SLID resistance and XDR-TB by type of testing (indirect versus direct testing). The populations of interest were adults with drug-susceptible TB or drug-resistant TB. The settings of interest were intermediate and central laboratories. Search methods We searched the following databases without any language restriction up to 30 January 2014: Cochrane Infectious Diseases Group Specialized Register; MEDLINE; EMBASE; ISI Web of Knowledge; MEDION; LILACS; BIOSIS; SCOPUS; the metaRegister of Controlled Trials; the search portal of the World Health Organization International Clinical Trials Registry Platform; and ProQuest Dissertations & Theses A&I. Selection criteria We included all studies that determined MTBDRsl accuracy against a defined reference standard (culture-based drug susceptibility testing (DST), genetic testing or both).We included cross-sectional and diagnostic case-control studies.We excluded unpublished data and conference proceedings. Data collection and analysis For each study, two review authors independently extracted data using a standardized form and assessed study quality using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. We performed meta-analyses to estimate the pooled sensitivity and specificity of MTBDRsl for FQ resistance, SLID resistance, and XDR-TB. We explored the influence of different reference standards. We performed the majority of analyses using a bivariate random-effects model against culture-based DST as the reference standard. Main results We included 21 unique studies: 14 studies reported the accuracy of MTBDRsl when done directly, five studies when done indirectly and two studies that did both. Of the 21 studies, 15 studies (71%) were cross-sectional and 11 studies (58%) were located in lowincome or middle-income countries. All studies but two were written in English. Nine (43%) of the 21 included studies had a high risk of bias for patient selection. At least half of the studies had low risk of bias for the other QUADAS-2 domains. As a test for FQ resistance measured against culture-based DST, the pooled sensitivity of MTBDRsl when performed indirectly was 83.1% (95% confidence interval (CI) 78.7% to 86.7%) and the pooled specificity was 97.7% (95% CI 94.3% to 99.1%), respectively (16 studies, 1766 participants; 610 confirmed cases of FQ-resistant TB; moderate quality evidence).When performed directly, the pooled sensitivity was 85.1% (95% CI 71.9% to 92.7%) and the pooled specificity was 98.2% (95% CI 96.8% to 99.0%), respectively (seven studies, 1033 participants; 230 confirmed cases of FQ-resistant TB; moderate quality evidence). For indirect testing for FQ resistance, four (0.2%) of 1766MTBDRsl results were indeterminate, whereas for direct testing 20 (1.9%) of 1033 wereMTBDRsl indeterminate (P < 0.001). As a test for SLID resistance measured against culture-based DST, the pooled sensitivity of MTBDRsl when performed indirectly was 76.9% (95% CI 61.1% to 87.6%) and the pooled specificity was 99.5% (95% CI 97.1% to 99.9%), respectively (14 studies, 1637 participants; 414 confirmed cases of SLID-resistant TB; moderate quality evidence). For amikacin resistance, the pooled sensitivity and specificity were 87.9% (95% CI 82.1% to 92.0%) and 99.5% (95% CI 97.5% to 99.9%), respectively. For kanamycin resistance, the pooled sensitivity and specificity were 66.9% (95% CI 44.1% to 83.8%) and 98.6% (95% CI 96.1% to 99.5%), respectively. for capreomycin resistance, the pooled sensitivity and specificity were 79.5% (95% CI 58.3% to 91.4%) and 95.8% (95% CI 93.4% to 97.3%), respectively. When performed directly, the pooled sensitivity for SLID resistance was 94.4% (95% CI 25.2% to 99.9%) and the pooled specificity was 98.2% (95% CI 88.9% to 99.7%), respectively (six studies, 947 participants; 207 confirmed cases of SLIDresistant TB, 740 SLID susceptible cases of TB; very low quality evidence). For indirect testing for SLID resistance, three (0.4%) of 774 MTBDRsl results were indeterminate, whereas for direct testing 53 (6.1%) of 873 were MTBDRsl indeterminate (P < 0.001). As a test for XDR-TB measured against culture-based DST, the pooled sensitivity of MTBDRsl when performed indirectly was 70.9% (95%CI 42.9%to 88.8%) and the pooled specificitywas 98.8%(95%CI 96.1%to 99.6%), respectively (eight studies, 880 participants; 173 confirmed cases of XDR-TB; low quality evidence). Authors’ conclusions In adults with TB, a positiveMTBDRsl result for FQ resistance, SLID resistance, or XDR-TB can be treated with confidence. However, MTBDRsl does not detect approximately one in five cases of FQ-resistant TB, and does not detect approximately one in four cases of SLID-resistant TB. Of the three SLIDs, MTBDRsl has the poorest sensitivity for kanamycin resistance. MTBDRsl will miss between one in four and one in three cases of XDR-TB. The diagnostic accuracy of MTBDRsl is similar when done using either culture isolates or smear-positive sputum. As the location of the resistance causing mutations can vary on a strain-by-strain basis, further research is required on test accuracy in different settings and, if genetic sequencing is used as a reference standard, it should examine all resistancedetermining regions. Given the confidence one can have in a positive result, and the ability of the test to provide results within a matter of days, MTBDRsl may be used as an initial test for second-line drug resistance. However, when the test reports a negative result, clinicians may still wish to carry out conventional testing. Plain Language Summary The rapid test GenoType® MTBDRsl for testing resistance to second-line TB drugs Background Different drugs are available to treat people with tuberculosis (TB), but resistance to these drugs is a growing problem. People with drug-resistant TB are more likely to die than people with drug-susceptible TB. People with drug-resistant TB require “second-line” TB drugs that, compared with “first-line” TB drugs used to treat drug-susceptible TB, cause more side effects and must be taken for longer. Extensively drug-resistant TB (XDR-TB) is a type of TB that is resistant to almost all TB drugs. A rapid and accurate test could identify people with drug-resistant TB, likely improve patient care, and reduce the spread of drug-resistant TB. Test evaluated by this review GenoType® MTBDRsl (MTBDRsl) is the only rapid test that detects resistance to second-line fluoroquinolone drugs and the secondline injectable drugs. The test also detects XDR-TB. MTBDRsl can be performed on TB bacteria grown by culture from sputum, which takes a long time (indirect testing), or immediately on sputum (direct testing). Main results We examined evidence available up to 30 January 2014 and included 21 studies, 11 of which were in low-income or middle-income countries. What do these results mean? Fluoroquinolone drugs By indirect testing, the test detected 83% of people with fluoroquinolone resistance and rarely gave a positive result for people without resistance. In a population of 1000 people,where 170 have fluoroquinolone resistance,MTBDRsl will correctly identify 141 people with fluoroquinolone resistance and miss 29 people. In this same population of 1000 people, where 830 people do not have fluoroquinolone resistance, the test will correctly classify 811 people as not having fluoroquinolone resistance and misclassify 19 people as having resistance (moderate quality evidence). By direct testing, the test detected 85% of people with fluoroquinolone resistance and rarely gave a positive result for people without resistance (moderate quality evidence). Second-line injectable drugs By indirect testing, the test detected 77%of people with second-line injectable drug resistance and rarely gave a positive result for people without resistance. In a population of 1000 people, where 230 have second-line injectable drug resistance, MTBDRsl will correctly identify 177 people with second-line injectable drug resistance and miss 53 people. In this same population of 1000 people, where 770 do not have second-line injectable drug resistance, the test will correctly classify 766 people as not having second-line injectable drug resistance and misclassify four people as having resistance (moderate quality evidence). By direct testing, the test detected 94% of people with second-line injectable drug resistance and rarely gave a positive result for people without resistance (very low quality evidence). XDR-TB By indirect testing, the test detected 71% of people with XDR-TB and rarely gave a positive result for people without XDR-TB. In a population of 1000 people, where 80 have XDR-TB, MTBDRsl will correctly identify 57 people with XDR-TB and miss 23 people. In this same population of 1000 people, where 920 do not have XDR-TB, the test will correctly classify 909 people as not having XDRTB and misclassify 11 people as having XDR-TB (low quality evidence). There was insufficient evidence to determine the accuracy of MTBDRsl by direct testing for XDR-TB. Conclusions The results show that a positive MTBDRsl result for resistance to the fluoroquinolone drugs or the second-line injectable drugs is reliable evidence that the person has drug-resistant TB and further conventional drug-resistance testing is not required. However, when the test reports a negative result, clinicians may still wish to carry out conventional testing. PMID:25353401
Lung ultrasound for the diagnosis of pneumonia in adults: a systematic review and meta-analysis
2014-01-01
Background Guidelines do not currently recommend the use of lung ultrasound (LUS) as an alternative to chest X-ray (CXR) or chest computerized tomography (CT) scan for the diagnosis of pneumonia. We conducted a meta-analysis to summarize existing evidence of the diagnostic accuracy of LUS for pneumonia in adults. Methods We conducted a systematic search of published studies comparing the diagnostic accuracy of LUS against a referent CXR or chest CT scan and/or clinical criteria for pneumonia in adults aged ≥18 years. Eligible studies were required to have a CXR and/or chest CT scan at the time of evaluation. We manually extracted descriptive and quantitative information from eligible studies, and calculated pooled sensitivity and specificity using the Mantel-Haenszel method and pooled positive and negative likelihood ratios (LR) using the DerSimonian-Laird method. We assessed for heterogeneity using the Q and I2 statistics. Results Our initial search strategy yielded 2726 articles, of which 45 (1.7%) were manually selected for review and 10 (0.4%) were eligible for analyses. These 10 studies provided a combined sample size of 1172 participants. Six studies enrolled adult patients who were either hospitalized or admitted to Emergency Departments with suspicion of pneumonia and 4 studies enrolled critically-ill adult patients. LUS was performed by highly-skilled sonographers in seven studies, by trained physicians in two, and one did not mention level of training. All studies were conducted in high-income settings. LUS took a maximum of 13 minutes to conduct. Nine studies used a 3.5-5 MHz micro-convex transducer and one used a 5–9 MHz convex probe. Pooled sensitivity and specificity for the diagnosis of pneumonia using LUS were 94% (95% CI, 92%-96%) and 96% (94%-97%), respectively; pooled positive and negative LRs were 16.8 (7.7-37.0) and 0.07 (0.05-0.10), respectively; and, the area-under-the-ROC curve was 0.99 (0.98-0.99). Conclusions Our meta-analysis supports that LUS, when conducted by highly-skilled sonographers, performs well for the diagnosis of pneumonia. General practitioners and Emergency Medicine physicians should be encouraged to learn LUS since it appears to be an established diagnostic tool in the hands of experienced physicians. PMID:24758612
The Diagnostic Value of Gastrin-17 Detection in Atrophic Gastritis
Wang, Xu; Ling, Li; Li, Shanshan; Qin, Guiping; Cui, Wei; Li, Xiang; Ni, Hong
2016-01-01
Abstract A meta-analysis was performed to assess the diagnostic value of gastrin-17 (G-17) for the early detection of chronic atrophic gastritis (CAG). An extensive literature search was performed, with the aim of selecting publications that reported the accuracy of G-17 in predicting CAG, in the following databases: PubMed, Science Direct, Web of Science, Chinese Biological Medicine, Chinese National Knowledge Infrastructure, Wanfang, and VIP. To assess the diagnostic value of G-17, the following statistics were estimated and described: sensitivity, specificity, diagnostic odds ratios (DOR), summary receiver operating characteristic curves, area under the curve (AUC), and 95% confidence intervals (CIs). Thirteen studies that met the inclusion criteria were included in this meta-analysis, comprising 894 patients and 1950 controls. The pooled sensitivity and specificity of these studies were 0.48 (95% CI: 0.45–0.51) and 0.79 (95% CI: 0.77–0.81), respectively. The DOR was 5.93 (95% CI: 2.93–11.99), and the AUC was 0.82. G-17 may have potential diagnostic value because it has good specificity and a moderate DOR and AUC for CAG. However, more studies are needed to improve the sensitivity of this diagnostic tool in the future. PMID:27149493
Boelman, Natalie T; Magney, Troy S; Logan, Barry A; Griffin, Kevin L; Eitel, Jan U H; Greaves, Heather; Prager, Case M; Vierling, Lee A
2016-09-01
As the Arctic warms, tundra vegetation is becoming taller and more structurally complex, as tall deciduous shrubs become increasingly dominant. Emerging studies reveal that shrubs exhibit photosynthetic resource partitioning, akin to forests, that may need accounting for in the "big leaf" net ecosystem exchange models. We conducted a lab experiment on sun and shade leaves from S. pulchra shrubs to determine the influence of both constitutive (slowly changing bulk carotenoid and chlorophyll pools) and facultative (rapidly changing xanthophyll cycle) pigment pools on a suite of spectral vegetation indices, to devise a rapid means of estimating within canopy resource partitioning. We found that: (1) the PRI of dark-adapted shade leaves (PRIo) was double that of sun leaves, and that PRIo was sensitive to variation among sun and shade leaves in both xanthophyll cycle pool size (V + A + Z) (r (2) = 0.59) and Chla/b (r (2) = 0.64); (2) A corrected PRI (difference between dark and illuminated leaves, ΔPRI) was more sensitive to variation among sun and shade leaves in changes to the epoxidation state of their xanthophyll cycle pigments (dEPS) (r (2) = 0.78, RMSE = 0.007) compared to the uncorrected PRI of illuminated leaves (PRI) (r (2) = 0.34, RMSE = 0.02); and (3) the SR680 index was correlated with each of (V + A + Z), lutein, bulk carotenoids, (V + A + Z)/(Chla + b), and Chla/b (r (2) range = 0.52-0.69). We suggest that ΔPRI be employed as a proxy for facultative pigment dynamics, and the SR680 for the estimation of constitutive pigment pools. We contribute the first Arctic-specific information on disentangling PRI-pigment relationships, and offer insight into how spectral indices can assess resource partitioning within shrub tundra canopies.
Estimating the magnitude of near-membrane PDE4 activity in living cells.
Xin, Wenkuan; Feinstein, Wei P; Britain, Andrea L; Ochoa, Cristhiaan D; Zhu, Bing; Richter, Wito; Leavesley, Silas J; Rich, Thomas C
2015-09-15
Recent studies have demonstrated that functionally discrete pools of phosphodiesterase (PDE) activity regulate distinct cellular functions. While the importance of localized pools of enzyme activity has become apparent, few studies have estimated enzyme activity within discrete subcellular compartments. Here we present an approach to estimate near-membrane PDE activity. First, total PDE activity is measured using traditional PDE activity assays. Second, known cAMP concentrations are dialyzed into single cells and the spatial spread of cAMP is monitored using cyclic nucleotide-gated channels. Third, mathematical models are used to estimate the spatial distribution of PDE activity within cells. Using this three-tiered approach, we observed two pharmacologically distinct pools of PDE activity, a rolipram-sensitive pool and an 8-methoxymethyl IBMX (8MM-IBMX)-sensitive pool. We observed that the rolipram-sensitive PDE (PDE4) was primarily responsible for cAMP hydrolysis near the plasma membrane. Finally, we observed that PDE4 was capable of blunting cAMP levels near the plasma membrane even when 100 μM cAMP were introduced into the cell via a patch pipette. Two compartment models predict that PDE activity near the plasma membrane, near cyclic nucleotide-gated channels, was significantly lower than total cellular PDE activity and that a slow spatial spread of cAMP allowed PDE activity to effectively hydrolyze near-membrane cAMP. These results imply that cAMP levels near the plasma membrane are distinct from those in other subcellular compartments; PDE activity is not uniform within cells; and localized pools of AC and PDE activities are responsible for controlling cAMP levels within distinct subcellular compartments. Copyright © 2015 the American Physiological Society.
Estimating the magnitude of near-membrane PDE4 activity in living cells
Xin, Wenkuan; Feinstein, Wei P.; Britain, Andrea L.; Ochoa, Cristhiaan D.; Zhu, Bing; Richter, Wito; Leavesley, Silas J.
2015-01-01
Recent studies have demonstrated that functionally discrete pools of phosphodiesterase (PDE) activity regulate distinct cellular functions. While the importance of localized pools of enzyme activity has become apparent, few studies have estimated enzyme activity within discrete subcellular compartments. Here we present an approach to estimate near-membrane PDE activity. First, total PDE activity is measured using traditional PDE activity assays. Second, known cAMP concentrations are dialyzed into single cells and the spatial spread of cAMP is monitored using cyclic nucleotide-gated channels. Third, mathematical models are used to estimate the spatial distribution of PDE activity within cells. Using this three-tiered approach, we observed two pharmacologically distinct pools of PDE activity, a rolipram-sensitive pool and an 8-methoxymethyl IBMX (8MM-IBMX)-sensitive pool. We observed that the rolipram-sensitive PDE (PDE4) was primarily responsible for cAMP hydrolysis near the plasma membrane. Finally, we observed that PDE4 was capable of blunting cAMP levels near the plasma membrane even when 100 μM cAMP were introduced into the cell via a patch pipette. Two compartment models predict that PDE activity near the plasma membrane, near cyclic nucleotide-gated channels, was significantly lower than total cellular PDE activity and that a slow spatial spread of cAMP allowed PDE activity to effectively hydrolyze near-membrane cAMP. These results imply that cAMP levels near the plasma membrane are distinct from those in other subcellular compartments; PDE activity is not uniform within cells; and localized pools of AC and PDE activities are responsible for controlling cAMP levels within distinct subcellular compartments. PMID:26201952
de Ruiter, C M; van der Veer, C; Leeflang, M M G; Deborggraeve, S; Lucas, C; Adams, E R
2014-09-01
Molecular methods have been proposed as highly sensitive tools for the detection of Leishmania parasites in visceral leishmaniasis (VL) patients. Here, we evaluate the diagnostic accuracy of these tools in a meta-analysis of the published literature. The selection criteria were original studies that evaluate the sensitivities and specificities of molecular tests for diagnosis of VL, adequate classification of study participants, and the absolute numbers of true positives and negatives derivable from the data presented. Forty studies met the selection criteria, including PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA), and loop-mediated isothermal amplification (LAMP). The sensitivities of the individual studies ranged from 29 to 100%, and the specificities ranged from 25 to 100%. The pooled sensitivity of PCR in whole blood was 93.1% (95% confidence interval [CI], 90.0 to 95.2), and the specificity was 95.6% (95% CI, 87.0 to 98.6). The specificity was significantly lower in consecutive studies, at 63.3% (95% CI, 53.9 to 71.8), due either to true-positive patients not being identified by parasitological methods or to the number of asymptomatic carriers in areas of endemicity. PCR for patients with HIV-VL coinfection showed high diagnostic accuracy in buffy coat and bone marrow, ranging from 93.1 to 96.9%. Molecular tools are highly sensitive assays for Leishmania detection and may contribute as an additional test in the algorithm, together with a clear clinical case definition. We observed wide variety in reference standards and study designs and now recommend consecutively designed studies. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Grødahl, Linn Helen J; Fawcett, Louise; Nazareth, Madeleine; Smith, Richard; Spencer, Simon; Heneghan, Nicola; Rushton, Alison
2016-08-01
In adolescent athletes, low back pain has a 1-year prevalence of 57% and causes include spondylolysis and spondylolisthesis. An accurate diagnosis enables healing, prevention of progression and return to sport. To evaluate the diagnostic utility of patient history and physical examination data to identify spondylolysis and/or spondylolisthesis in athletes. Systematic review was undertaken according to published guidelines, and reported in line with PRISMA. Key databases were searched up to 13/11/15. athletic population with LBP, patient history and/or physical examination accuracy data for spondylolysis and/or spondylolisthesis, any study design including raw data. Two reviewers independently assessed risk of bias (ROB) using QUADAS-2. A data extraction sheet was pre-designed. Pooling of data and investigation for heterogeneity enabled a qualitative synthesis of data across studies. Of the eight included studies, two were assessed as low ROB, one of which also had no concerns regarding applicability. Age (<20 years) demonstrated 81% sensitivity and 44% specificity and gender (male) 73% sensitivity and 57% specificity for spondylolysis. Difficulty falling asleep, waking up because of pain, pain worse with sitting and walking all have sensitivity >75% for spondylolisthesis. Step-deformity palpation demonstrated 60-88% sensitivity and 87-100% specificity for spondylolisthesis. The one-legged hyperextension test was not supported for spondylolysis (sensitivity 50-73%, specificity 0-87%). No recommendations can be made utilising patient history data. Based on one low ROB study, step deformity palpation may be useful in diagnosing spondylolisthesis. No physical tests demonstrated diagnostic utility for spondylolysis. Further research is required. Copyright © 2016 Elsevier Ltd. All rights reserved.
Salmonella testing of pooled pre-enrichment broth cultures for screening multiple food samples.
Price, W R; Olsen, R A; Hunter, J E
1972-04-01
A method has been described for testing multiple food samples for Salmonella without loss in sensitivity. The method pools multiple pre-enrichment broth cultures into single enrichment broths. The subsequent stages of the Salmonella analysis are not altered. The method was found applicable to several dry food materials including nonfat dry milk, dried egg albumin, cocoa, cottonseed flour, wheat flour, and shredded coconut. As many as 25 pre-enrichment broth cultures were pooled without apparent loss in the sensitivity of Salmonella detection as compared to individual sample analysis. The procedure offers a simple, yet effective, way to increase sample capacity in the Salmonella testing of foods, particularly where a large proportion of samples ordinarily is negative. It also permits small portions of pre-enrichment broth cultures to be retained for subsequent individual analysis if positive tests are found. Salmonella testing of pooled pre-enrichment broths provides increased consumer protection for a given amount of analytical effort as compared to individual sample analysis.
CRISPR-UMI: single-cell lineage tracing of pooled CRISPR-Cas9 screens.
Michlits, Georg; Hubmann, Maria; Wu, Szu-Hsien; Vainorius, Gintautas; Budusan, Elena; Zhuk, Sergei; Burkard, Thomas R; Novatchkova, Maria; Aichinger, Martin; Lu, Yiqing; Reece-Hoyes, John; Nitsch, Roberto; Schramek, Daniel; Hoepfner, Dominic; Elling, Ulrich
2017-12-01
Pooled CRISPR screens are a powerful tool for assessments of gene function. However, conventional analysis is based exclusively on the relative abundance of integrated single guide RNAs (sgRNAs) between populations, which does not discern distinct phenotypes and editing outcomes generated by identical sgRNAs. Here we present CRISPR-UMI, a single-cell lineage-tracing methodology for pooled screening to account for cell heterogeneity. We generated complex sgRNA libraries with unique molecular identifiers (UMIs) that allowed for screening of clonally expanded, individually tagged cells. A proof-of-principle CRISPR-UMI negative-selection screen provided increased sensitivity and robustness compared with conventional analysis by accounting for underlying cellular and editing-outcome heterogeneity and detection of outlier clones. Furthermore, a CRISPR-UMI positive-selection screen uncovered new roadblocks in reprogramming mouse embryonic fibroblasts as pluripotent stem cells, distinguishing reprogramming frequency and speed (i.e., effect size and probability). CRISPR-UMI boosts the predictive power, sensitivity, and information content of pooled CRISPR screens.
Arnold, Mark E; Mueller-Doblies, Doris; Gosling, Rebecca J; Martelli, Francesca; Davies, Robert H
2015-01-01
Reports of Salmonella in ducks in the UK currently rely upon voluntary submissions from the industry, and as there is no harmonized statutory monitoring and control programme, it is difficult to compare data from different years in order to evaluate any trends in Salmonella prevalence in relation to sampling methodology. Therefore, the aim of this project was to assess the sensitivity of a selection of environmental sampling methods, including the sampling of faeces, dust and water troughs or bowls for the detection of Salmonella in duck flocks, and a range of sampling methods were applied to 67 duck flocks. Bayesian methods in the absence of a gold standard were used to provide estimates of the sensitivity of each of the sampling methods relative to the within-flock prevalence. There was a large influence of the within-flock prevalence on the sensitivity of all sample types, with sensitivity reducing as the within-flock prevalence reduced. Boot swabs (individual and pool of four), swabs of faecally contaminated areas and whole house hand-held fabric swabs showed the overall highest sensitivity for low-prevalence flocks and are recommended for use to detect Salmonella in duck flocks. The sample type with the highest proportion positive was a pool of four hair nets used as boot swabs, but this was not the most sensitive sample for low-prevalence flocks. All the environmental sampling types (faeces swabs, litter pinches, drag swabs, water trough samples and dust) had higher sensitivity than individual faeces sampling. None of the methods consistently identified all the positive flocks, and at least 10 samples would be required for even the most sensitive method (pool of four boot swabs) to detect a 5% prevalence. The sampling of dust had a low sensitivity and is not recommended for ducks.
Hafeez, Mian A; Shivaramaiah, Srichaitanya; Dorsey, Kristi Moore; Ogedengbe, Mosun E; El-Sherry, Shiem; Whale, Julia; Cobean, Julie; Barta, John R
2015-05-01
Species-specific PCR primers targeting the mitochondrial cytochrome c oxidase subunit I (mtCOI) locus were generated that allow for the specific identification of the most common Eimeria species infecting turkeys (i.e., Eimeria adenoeides, Eimeria meleagrimitis, Eimeria gallopavonis, Eimeria meleagridis, Eimeria dispersa, and Eimeria innocua). PCR reaction chemistries were optimized with respect to divalent cation (MgCl2) and dNTP concentrations, as well as PCR cycling conditions (particularly anneal temperature for primers). Genomic DNA samples from single oocyst-derived lines of six Eimeria species were tested to establish specificity and sensitivity of these newly designed primer pairs. A mixed 60-ng total DNA sample containing 10 ng of each of the six Eimeria species was used as DNA template to demonstrate specific amplification of the correct product using each of the species-specific primer pairs. Ten nanograms of each of the five non-target Eimeria species was pooled to provide a non-target, control DNA sample suitable to test the specificity of each primer pair. The amplifications of the COI region with species-specific primer pairs from pooled samples yielded products of expected sizes (209 to 1,012 bp) and no amplification of non-target Eimeria sp. DNA was detected using the non-target, control DNA samples. These primer pairs specific for Eimeria spp. of turkeys did not amplify any of the seven Eimeria species infecting chickens. The newly developed PCR primers can be used as a diagnostic tool capable of specifically identifying six turkey Eimeria species; additionally, sequencing of the PCR amplification products yields sequence-based genotyping data suitable for identification and molecular phylogenetics.
Reyes, John Carlo B; Solon, Juan Antonio A; Rivera, Windell L
2014-07-01
A loop-mediated isothermal amplification (LAMP) assay targeting the 2-kbp repeated DNA species-specific sequence was developed for detection of Trichomonas vaginalis, the causative agent of trichomoniasis. The analytical sensitivity and specificity of the LAMP assay were evaluated using pooled genital swab and urine specimens, respectively, spiked with T. vaginalis trophozoites. Genital secretion and urine did not inhibit the detection of the parasite. The sensitivity of the LAMP was 10-1000 times higher than the PCR performed. The detection limit of LAMP was 1 trichomonad for both spiked genital swab and urine specimens. Also, LAMP did not exhibit cross-reactivity with closely-related trichomonads, Trichomonas tenax and Pentatrichomonas hominis, and other enteric and urogenital microorganisms, Entamoeba histolytica, Candida albicans, Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus. This is the first report of a LAMP assay for the detection of T. vaginalis and has prospective application for rapid diagnosis and control of trichomoniasis. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saito, H.; Goldsmith, G.H. Jr.
A specific, sensitive, and reproducible radioimmunoassay for human plasma thromboplastin antecedent (PTA, factor XI) has been developed with purified PTA and monospecific rabbit antiserum. Precise measurements of PTA antigen were possible for concentrations as low as 0.3% of that in normal pooled plasma. Normal plasma contained approximately 6 ..mu..g PTA/ml. A good correlation (correlation coefficient 0.68) existed between the PTA procoagulant assays and radioimmunoassays among 50 normal adults (25 males and 25 females). PTA antigen was markedly reduced in plasma of 13 patients with congenital homozygous PTA deficiency (range <0.003-0.128 U/ml) and 9 patients with hepatic cirrhosis (0.35 +- 0.17more » U/ml), but was normal in those of 9 patients under treatment with warfarin, 8 patients with disseminated intravascular coagulation and 16 patients with other congenital clotting factor abnormalities, including prekallikrein deficiency (Fletcher trait) and high molecular weight kininogen deficiency (Fitzgerald trait).« less
Dones, Valentin C; Grimmer, Karen; Thoirs, Kerry; Suarez, Consuelo G; Luker, Julie
2014-03-03
Ultrasound is considered a reliable, widely available, non-invasive and inexpensive imaging technique for assessing soft tissue involvement in Lateral epicondylalgia. Despite the number of diagnostic studies for Lateral Epicondylalgia, there is no consensus in the current literature on the best abnormal ultrasound findings that confirm lateral epicondylalgia. Eligible studies identified by searching electronic databases, scanning reference lists of articles and chapters on ultrasound in reference books, and consultation of experts in sonography. Three reviewers (VCDIII, KP, KW) independently searched the databases using the agreed search strategy, and independently conducted all stages of article selection. Two reviewers (VCDIII, KP) then screened titles and abstracts to remove obvious irrelevance. Potentially relevant full text publications which met the inclusion criteria were reviewed by the primary investigator (VCDIII) and another reviewer (CGS). Among the 15 included diagnostic studies in this review, seven were Level II diagnostic accuracy studies for chronic lateral epicondylalgia based on the National Health and Medical Research Council Hierarchy of Evidence. Based from the pooled sensitivity of abnormal ultrasound findings with homogenous results (p > 0.05), the hypoechogenicity of the common extensor origin has the best combination of diagnostic sensitivity and specificity. It is moderately sensitive [Sensitivity: 0.64 (0.56-0.72)] and highly specific [Specificity: 0.82 (0.72-0.90)] in determining elbows with lateral epicondylalgia. Additionally, bone changes on the lateral epicondyle [Sensitivity: 0.56 (0.50-0.62)] were moderately sensitive to chronic LE. Conversely, neovascularity [Specificity: 1.00 (0.97-1.00)], calcifications [Specificity: 0.97 (0.94-0.99)] and cortical irregularities [Specificity: 0.96 (0.88-0.99)] have strong specificity for chronic lateral epicondylalgia. There is insufficient evidence supporting the use of Power Doppler Ultrasonogrophy, Real-time Sonoelastography and sonographic probe-induced tenderness in diagnosing LE. The use of Gray-scale Ultrasonography is recommended in objectively diagnosing lateral epicondylalgia. The presence of hypoechogenicity and bone changes indicates presence of a stressed common extensor origin-lateral epicondyle complex in elbows with lateral epicondylalgia. In addition to diagnosis, detection of these abnormal ultrasound findings allows localization of pathologies to tendon or bone that would assist in designing an appropriate treatment suited to patient's condition.
Design of hydrotherapy exercise pools.
Edlich, R F; Abidin, M R; Becker, D G; Pavlovich, L J; Dang, M T
1988-01-01
Several hydrotherapy pools have been designed specifically for a variety of aquatic exercise. Aqua-Ark positions the exerciser in the center of the pool for deep-water exercise. Aqua-Trex is a shallow underwater treadmill system for water walking or jogging. Swim-Ex generates an adjustable laminar flow that permits swimming without turning. Musculoskeletal conditioning can be accomplished in the above-ground Arjo shallow-water exercise pool. A hydrotherapy pool also can be custom designed for musculoskeletal conditioning in its shallow part and cardiovascular conditioning in a deeper portion of the pool. Regardless of the type of exercise, there is general agreement that the specific exercise conducted in water requires significantly more energy expenditure than when the same exercise is performed on land.
Cyst fluid analysis in the differential diagnosis of pancreatic cystic lesions: a pooled analysis.
van der Waaij, Laurens A; van Dullemen, Hendrik M; Porte, Robert J
2005-09-01
Pancreatic cystic tumors commonly include serous cystadenoma (SCA), mucinous cystadenoma (MCA), and mucinous cystadenocarcinoma (MCAC). A differential diagnosis with pseudocysts (PC) can be difficult. Radiologic criteria are not reliable. The objective of the study is to investigate the value of cyst fluid analysis in the differential diagnosis of benign (SCA, PC) vs. premalignant or malignant (MCA, MCAC) lesions. A search in PubMed was performed with the search terms cyst, pancrea, and fluid. Articles about cyst fluid analysis of pancreatic lesions that contained the individual data of at least 7 patients were included in the study. Data of all individual patients were combined and were plotted in scatter grams. Cutoff levels were determined. Twelve studies were included, which comprised data of 450 patients. Cysts with an amylase concentration <250 U/L were SCA, MCA, or MCAC (sensitivity 44%, specificity 98%) and, thus, virtually excluded PC. A carcinoembryonic antigen (CEA) <5 ng/mL suggested a SCA or PC (sensitivity 50%, specificity 95%). A CEA >800 ng/mL strongly suggested MCA or MCAC (sensitivity 48%, specificity 98%). A carbohydrate-associated antigen (CA) 19-9 <37 U/mL strongly suggested PC or SCA (sensitivity 19%, specificity 98%). Cytologic examination revealed malignant cells in 48% of MCAC (n = 111). Most pancreatic cystic tumors should be resected without the need for cyst fluid analysis. However, in asymptomatic patients, in patients with an increased surgical risk, and, in patients in whom there is a diagnostic uncertainty about the presence of a PC, cyst fluid analysis helps to determine the optimal therapeutic strategy.
Gui, Xuwei; Xiao, Heping
2014-01-01
This systematic review and meta-analysis was performed to determine accuracy and usefulness of adenosine deaminase (ADA) in diagnosis of tuberculosis pleurisy. Medline, Google scholar and Web of Science databases were searched to identify related studies until 2014. Two reviewers independently assessed quality of studies included according to standard Quality Assessment of Diagnosis Accuracy Studies (QUADAS) criteria. The sensitivity, specificity, diagnostic odds ratio and other parameters of ADA in diagnosis of tuberculosis pleurisy were analyzed with Meta-DiSC1.4 software, and pooled using the random effects model. Twelve studies including 865 tuberculosis pleurisy patients and 1379 non-tuberculosis pleurisy subjects were identified from 110 studies for this meta-analysis. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnosis odds ratio (DOR) of ADA in the diagnosis of tuberculosis pleurisy were 45.25 (95% CI 27.63-74.08), 0.86 (95% CI 0.84-0.88), 0.88 (95% CI 0.86-0.90), 6.32 (95% CI 4.83-8.26) and 0.15 (95% 0.11-0.22), respectively. The area under the summary receiver operating characteristic curve (SROC) was 0.9340. Our results demonstrate that the sensitivity and specificity of ADA are high in the diagnosis of tuberculosis pleurisy especially when ADA≥50 (U/L). Thus, ADA is a relatively sensitive and specific marker for tuberculosis pleurisy diagnosis. However, it is cautious to apply these results due to the heterogeneity in study design of these studies. Further studies are required to confirm the optimal cut-off value of ADA.
Evangelista, Laura; Cuocolo, Alberto; Pace, Leonardo; Mansi, Luigi; Del Vecchio, Silvana; Miletto, Paolo; Sanfilippo, Silvia; Pellegrino, Sara; Guerra, Luca; Pepe, Giovanna; Peluso, Giuseppina; Salvatore, Marco; Galicchio, Rosj; Zuffante, Michele; Annunziata, Salvatore; Farsad, Mohsen; Chiaravalloti, Agostino; Spadafora, Marco
2018-05-07
The aim of this study was to determine the performance of 18 F-FDG-PET/CT in patients with solitary pulmonary nodule (SPN), stratifying the risk according to the likelihood of pulmonary malignancy. FDG-PET/CT of 502 patients, stratified for pre-test cancer risk, were retrospectively analyzed. FDG uptake in SPN was assessed by a 4-point scoring system and semiquantitative analysis using the ratio between SUVmax in SPN and SUVmean in mediastinal blood pool (BP) and between SUVmax in SPN and SUVmean in liver (L). Histopathology and/or follow-up data were used as standard of reference. SPN was malignant in 180 (36%) patients, benign in 175 (35%), and indeterminate in 147 (29%). The 355 patients with a definitive SPN nature (malignant or benign) were considered for the analysis. Considering FDG uptake ≥ 2, sensitivity, specificity, positive (PPV) and negative (NPV) predictive values, and accuracy were 85.6%, 85.7%, 86%, 85.2%, and 85.6% respectively. Sensitivity and PPV were higher (P < 0.05) in intermediate and high-risk patients, while specificity and NPV were higher (P < 0.05) in low-risk patients. On receiver operating characteristic curve analysis, the cut-offs for better discrimination between benign and malignant SPN were 1.56 (sensitivity 81% and specificity 87%) and 1.12 (sensitivity 81% and specificity 86%) for SUVmax/SUVmeanBP and SUVmax/SUVmeanL respectively. In intermediate and high-risk patients, including the SUVmax/SUVmeanBP, the specificity shifted from 85% and 50% to 100%. Visual FDG-PET/CT has an acceptable performance in patients with SPN, but accuracy improves when SUVratios are considered, particularly in patients with intermediate and high risk of malignancy.
Cirelli, Kimberly M.; Dan, Jennifer M.; Morou, Antigoni; Daigneault, Audrey; Brassard, Nathalie; Silvestri, Guido; Routy, Jean-Pierre; Havenar-Daughton, Colin; Crotty, Shane
2017-01-01
The identification and study of antigen-specific CD4 T cells, both in peripheral blood and in tissues, is key for a broad range of immunological research, including vaccine responses and infectious diseases. Detection of these cells is hampered by both their rarity and their heterogeneity, in particular with regards to cytokine secretion profiles. These factors prevent the identification of the total pool of antigen-specific CD4 T cells by classical methods. We have developed assays for the highly sensitive detection of such cells by measuring the upregulation of surface activation induced markers (AIM). Here, we compare two such assays based on concurrent expression of CD69 plus CD40L (CD154) or expression of OX40 plus CD25, and we develop additional AIM assays based on OX40 plus PD-L1 or 4-1BB. We compare the relative sensitivity of these assays for detection of vaccine and natural infection-induced CD4 T cell responses and show that these assays identify distinct, but overlapping populations of antigen-specific CD4 T cells, a subpopulation of which can also be detected on the basis of cytokine synthesis. Bystander activation had minimal effect on AIM markers. However, some T regulatory cells upregulate CD25 upon antigen stimulation. We therefore validated AIM assays designed to exclude most T regulatory cells, for both human and non-human primate (NHP, Macaca mulatta) studies. Overall, through head-to-head comparisons and methodological improvements, we show that AIM assays represent a sensitive and valuable method for the detection of antigen-specific CD4 T cells. PMID:29065175
Reiss, Samantha; Baxter, Amy E; Cirelli, Kimberly M; Dan, Jennifer M; Morou, Antigoni; Daigneault, Audrey; Brassard, Nathalie; Silvestri, Guido; Routy, Jean-Pierre; Havenar-Daughton, Colin; Crotty, Shane; Kaufmann, Daniel E
2017-01-01
The identification and study of antigen-specific CD4 T cells, both in peripheral blood and in tissues, is key for a broad range of immunological research, including vaccine responses and infectious diseases. Detection of these cells is hampered by both their rarity and their heterogeneity, in particular with regards to cytokine secretion profiles. These factors prevent the identification of the total pool of antigen-specific CD4 T cells by classical methods. We have developed assays for the highly sensitive detection of such cells by measuring the upregulation of surface activation induced markers (AIM). Here, we compare two such assays based on concurrent expression of CD69 plus CD40L (CD154) or expression of OX40 plus CD25, and we develop additional AIM assays based on OX40 plus PD-L1 or 4-1BB. We compare the relative sensitivity of these assays for detection of vaccine and natural infection-induced CD4 T cell responses and show that these assays identify distinct, but overlapping populations of antigen-specific CD4 T cells, a subpopulation of which can also be detected on the basis of cytokine synthesis. Bystander activation had minimal effect on AIM markers. However, some T regulatory cells upregulate CD25 upon antigen stimulation. We therefore validated AIM assays designed to exclude most T regulatory cells, for both human and non-human primate (NHP, Macaca mulatta) studies. Overall, through head-to-head comparisons and methodological improvements, we show that AIM assays represent a sensitive and valuable method for the detection of antigen-specific CD4 T cells.
Yo, Chia-Hung; Lee, Si-Huei; Chang, Shy-Shin; Lee, Matthew Chien-Hung; Lee, Chien-Chang
2014-02-20
We performed a systematic review and meta-analysis of studies on high-sensitivity C-reactive protein (hs-CRP) assays to see whether these tests are predictive of atrial fibrillation (AF) recurrence after cardioversion. Systematic review and meta-analysis. PubMed, EMBASE and Cochrane databases as well as a hand search of the reference lists in the retrieved articles from inception to December 2013. This review selected observational studies in which the measurements of serum CRP were used to predict AF recurrence. An hs-CRP assay was defined as any CRP test capable of measuring serum CRP to below 0.6 mg/dL. We summarised test performance characteristics with the use of forest plots, hierarchical summary receiver operating characteristic curves and bivariate random effects models. Meta-regression analysis was performed to explore the source of heterogeneity. We included nine qualifying studies comprising a total of 347 patients with AF recurrence and 335 controls. A CRP level higher than the optimal cut-off point was an independent predictor of AF recurrence after cardioversion (summary adjusted OR: 3.33; 95% CI 2.10 to 5.28). The estimated pooled sensitivity and specificity for hs-CRP was 71.0% (95% CI 63% to 78%) and 72.0% (61% to 81%), respectively. Most studies used a CRP cut-off point of 1.9 mg/L to predict long-term AF recurrence (77% sensitivity, 65% specificity), and 3 mg/L to predict short-term AF recurrence (73% sensitivity, 71% specificity). hs-CRP assays are moderately accurate in predicting AF recurrence after successful cardioversion.
David George Lonzarich; Melvin L. Warren; Mary Ruth Elger Lonzrich
1998-01-01
The authors removed fish from pools in two Arkansas streams to determine recolonization rates and the effects of isolation (i.e., riffle length, riffle depth, distance to large source pools, and location), pool area, and assemblage size on recovery. To determine pool-specific recovery rates, the authors repeatedly snorkeled 12 pools over a 40-day recovery period....
Diagnostic accuracy of Xpert MTB/RIF assay for musculoskeletal tuberculosis: a meta-analysis.
Wen, Hai; Li, Pengzhi; Ma, Hong; Lv, Guohua
2017-01-01
Xpert MTB/RIF assay, a rapid and automated real-time nucleic acid amplification test, has been reported for the diagnosis of musculoskeletal tuberculosis (TB) in current years. This meta-analysis aims to determine the diagnostic accuracy of Xpert for the detection of musculoskeletal TB and rifampicin (RIF) resistance. We searched PubMed, Embase, China National Knowledge Infrastructure, and Wanfang for original articles published up to 1st June 2017 to identify studies in which the Xpert assay was applied to diagnose musculoskeletal TB. Pooled estimates were calculated using a random-effects model or a fixed-effects model according to heterogeneity. Summary receiver operating characteristic curves and the area under the curve (AUC) were used to summarize overall diagnostic performance. Deeks' test was performed to evaluate potential publication bias. Twelve studies were identified with a pooled sensitivity and specificity of respectively 0.81 (95% confidence interval [CI] 0.78-0.83) and 0.83 (95% CI 0.80-0.86) of Xpert for the diagnosis of musculoskeletal TB. Xpert was highly sensitive (0.89, 95% CI 0.79-0.95) and highly specific (0.96, 95% CI 0.92-0.98) in detecting RIF resistance. AUC (over 0.9) suggested a relatively high level of overall diagnostic accuracy of Xpert for detecting musculoskeletal TB and RIF resistance. Prevalence and reference standard were indicated to be sources of heterogeneity between studies. No publication bias was found. This study provides available evidence of the rapid and effective role of Xpert in diagnosing musculoskeletal TB and detecting RIF resistance.
Fish oil supplementation and insulin sensitivity: a systematic review and meta-analysis.
Gao, Huanqing; Geng, Tingting; Huang, Tao; Zhao, Qinghua
2017-07-03
Fish oil supplementation has been shown to be associated with a lower risk of metabolic syndrome and benefit a wide range of chronic diseases, such as cardiovascular disease, type 2 diabetes and several types of cancers. However, the evidence of fish oil supplementation on glucose metabolism and insulin sensitivity is still controversial. This meta-analysis summarized the exist evidence of the relationship between fish oil supplementation and insulin sensitivity and aimed to evaluate whether fish oil supplementation could improve insulin sensitivity. We searched the Cochrane Library, PubMed, Embase database for the relevant studies update to Dec 2016. Two researchers screened the literature independently by the selection and exclusion criteria. Studies were pooled using random effect models to estimate a pooled SMD and corresponding 95% CI. This meta-analysis was performed by Stata 13.1 software. A total of 17 studies with 672 participants were included in this meta-analysis study after screening from 498 published articles found after the initial search. In a pooled analysis, fish oil supplementation had no effects on insulin sensitivity compared with the placebo (SMD 0.17, 95%CI -0.15 to 0.48, p = 0.292). In subgroup analysis, fish oil supplementation could benefit insulin sensitivity among people who were experiencing at least one symptom of metabolic disorders (SMD 0.53, 95% CI 0.17 to 0.88, p < 0.001). Similarly, there were no significant differences between subgroups of methods of insulin sensitivity, doses of omega-3 polyunsaturated fatty acids (n-3 PUFA) of fish oil supplementation or duration of the intervention. The sensitivity analysis indicated that the results were robust. Short-term fish oil supplementation is associated with increasing the insulin sensitivity among those people with metabolic disorders.
Grazing impacts on infiltration rates at Vernal Pools in the Modoc Plateau
USDA-ARS?s Scientific Manuscript database
Vernal pools are depressions of land that are seasonally inundated with water. They host rare and endemic plant and animal species and are sensitive to livestock grazing management and climate change impacts on hydrology and vegetation. Climate change forecasts predicting a hotter, drier climate sug...
Evaluating linguistic equivalence of patient-reported outcomes in a cancer clinical trial.
Hahn, Elizabeth A; Bode, Rita K; Du, Hongyan; Cella, David
2006-01-01
In order to make meaningful cross-cultural or cross-linguistic comparisons of health-related quality of life (HRQL) or to pool international research data, it is essential to create unbiased measures that can detect clinically important differences. When HRQL scores differ between cultural/linguistic groups, it is important to determine whether this reflects real group differences, or is the result of systematic measurement variability. To investigate the linguistic measurement equivalence of a cancer-specific HRQL questionnaire, and to conduct a sensitivity analysis of treatment differences in HRQL in a clinical trial. Patients with newly diagnosed chronic myelogenous leukemia (n = 1049) completed serial HRQL assessments in an international Phase III trial. Two types of differential item functioning (uniform and non-uniform) were evaluated using item response theory and classical test theory approaches. A sensitivity analysis was conducted to compare HRQL between treatment arms using items without evidence of differential functioning. Among 27 items, nine (33%) did not exhibit any evidence of differential functioning in both linguistic comparisons (English versus French, English versus German). Although 18 items functioned differently, there was no evidence of systematic bias. In a sensitivity analysis, adjustment for differential functioning affected the magnitude, but not the direction or interpretation of clinical trial treatment arm differences. Sufficient sample sizes were available for only three of the eight language groups. Identification of differential functioning in two-thirds of the items suggests that current psychometric methods may be too sensitive. Enhanced methodologies are needed to differentiate trivial from substantive differential item functioning. Systematic variability in HRQL across different groups can be evaluated for its effect upon clinical trial results; a practice recommended when data are pooled across cultural or linguistic groups to make conclusions about treatment effects.
Li, S; Tang, X; Peng, L; Luo, Y; Dong, R; Liu, J
2015-05-01
To review the literature on the diagnostic accuracy of CT-derived fractional flow reserve (FFRCT) for the evaluation of myocardial ischaemia in patients with suspected or known coronary artery disease, with invasive fractional flow reserve (FFR) as the reference standard. A PubMed, EMBASE, and Cochrane cross-search was performed. The pooled diagnostic accuracy of FFRCT, with FFR as the reference standard, was primarily analysed, and then compared with that of CT angiography (CTA). The thresholds to diagnose ischaemia were FFR ≤0.80 or CTA ≥50% stenosis. Data extraction, synthesis, and statistical analysis were performed by standard meta-analysis methods. Three multicentre studies (NXT Trial, DISCOVER-FLOW study and DeFACTO study) were included, examining 609 patients and 1050 vessels. The pooled sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), negative likelihood ratio (LR-), and diagnostic odds ratio (DOR) for FFRCT were 89% (85-93%), 71% (65-75%), 70% (65-75%), 90% (85-93%), 3.31 (1.79-6.14), 0.16 (0.11-0.23), and 21.21 (9.15-49.15) at the patient-level, and 83% (78-63%), 78% (75-81%), 61% (56-65%), 92% (89-90%), 4.02 (1.84-8.80), 0.22 (0.13-0.35), and 19.15 (5.73-63.93) at the vessel-level. At per-patient analysis, FFRCT has similar sensitivity but improved specificity, PPV, NPV, LR+, LR-, and DOR versus those of CTA. At per-vessel analysis, FFRCT had a slightly lower sensitivity, similar NPV, but improved specificity, PPV, LR+, LR-, and DOR compared with those of CTA. The area under the summary receiver operating characteristic curves for FFRCT was 0.8909 at patient-level and 0.8865 at vessel-level, versus 0.7402 for CTA at patient-level. FFRCT, which was associated with improved diagnostic accuracy versus CTA, is a viable alternative to FFR for detecting coronary ischaemic lesions. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
de Azevedo, Priscila Zacarias; Sylvestre, Tatiane Fernanda; Cavalcante, Ricardo de Souza; de Carvalho, Lídia Raquel; Moris, Daniela Vanessa; de Oliveira, Maria Luiza Cotrim Sartor; Mendes, Rinaldo Poncio
2015-01-01
The diagnosis of chronic pulmonary aspergillosis (CPA) depends on the radiologic image and the identification of specific antibodies. The present study aimed to evaluate accuracy parameters of enzyme-linked immunosorbent assay (ELISA) and of the determination of serum galactomannan level in the diagnosis of patients with CPA, comparing these results with the double agar gel immunodiffusion (DID) test. In addition, the prevalence of cross-reactivity and the serological progression after treatment were evaluated by comparing DID and ELISA. Six study groups were formed: G1: 22 patients with CPA, 17 of whom had Aspergillus fungus ball, one chronic cavitary pulmonary aspergillosis (CCPA) and four chronic fibrosing pulmonary aspergillosis (CFPA); G2: 28 patients with pulmonary tuberculosis (TB); G3: 23 patients with histoplasmosis (HST); G4: 50 patients with paracoccidioidomycosis (PCM); G5: 20 patients with cryptococcosis (CRC); and G6: 200 healthy controls. Serum antibodies were measured by DID and ELISA, with two antigen preparations—Aspergillus fumigatus (DID1, ELISA1) and a pool of A. fumigatus, A. flavus and A. niger antigens (DID2, ELISA2). The Platélia Aspergillus Enzyme Immunoassay (EIA) kit was used to measure galactomannan. The cut-off points of ELISA were determined for each antigen preparation and for the 95% and 99% confidence intervals. Despite the low sensitivity, DID was the technique of choice due to its specificity, positive and negative predictive values and positive likelihood ratio–especially with the antigen pool and due to the low frequency of cross-reactivity. ELISA1 and a 0.090 cut-off showed high sensitivity, specificity and negative predictive value, but a high frequency of cross-reactivity with CRC. The best degree of agreement was observed between ELISA1 and ELISA2. The detection of serum galactomannan showed high sensitivity, comparable to ELISA2. The immunodiffusion test showed an excellent relationship with the progression after treatment, which made it the reaction of choice for patient follow-up. PMID:26271000
In vivo insertion pool sequencing identifies virulence factors in a complex fungal–host interaction
Uhse, Simon; Pflug, Florian G.; Stirnberg, Alexandra; Ehrlinger, Klaus; von Haeseler, Arndt
2018-01-01
Large-scale insertional mutagenesis screens can be powerful genome-wide tools if they are streamlined with efficient downstream analysis, which is a serious bottleneck in complex biological systems. A major impediment to the success of next-generation sequencing (NGS)-based screens for virulence factors is that the genetic material of pathogens is often underrepresented within the eukaryotic host, making detection extremely challenging. We therefore established insertion Pool-Sequencing (iPool-Seq) on maize infected with the biotrophic fungus U. maydis. iPool-Seq features tagmentation, unique molecular barcodes, and affinity purification of pathogen insertion mutant DNA from in vivo-infected tissues. In a proof of concept using iPool-Seq, we identified 28 virulence factors, including 23 that were previously uncharacterized, from an initial pool of 195 candidate effector mutants. Because of its sensitivity and quantitative nature, iPool-Seq can be applied to any insertional mutagenesis library and is especially suitable for genetically complex setups like pooled infections of eukaryotic hosts. PMID:29684023
NASA Astrophysics Data System (ADS)
van der Voort, Tessa Sophia; Hagedorn, Frank; McIntyre, Cameron; Zell, Claudia; Eglinton, Timothy Ian
2017-04-01
Soil carbon constitutes the largest terrestrial reservoir of organic carbon, and therefore understanding the mechanisms and drivers of carbon stabilization is crucial, especially in the framework of climate change. The understanding of the dependence of soil organic turnover in specific carbon pools as related to e.g. climate, soil texture and mineralogy is limited. In this framework, radiocarbon constitutes a uniquely powerful tool that help to unravel carbon dynamics from decadal to millennial timescales. This project combines bulk and pool-specific radiocarbon analyses in the top and deep soil on a wide range of forested soils that span a large climatic gradient (MAT 1.3-9.2°C, MAP 600 to 2100 mm m-2y-1). These well-studies sites are part of the Long-Term Forest Ecosystem Research (LWF) program of the Swiss Federal Institute for Forest, Snow and Landscape research (WSL). This study aims to combine the insights gained from bulk and pool-specific turnover to environmental conditions and molecular composition of soil carbon. The pools investigated span the mineral-associated (occluded and heavy fractions from density fractionation) and potentially water-soluble (free light fractions from density fractionation and water extractable organic carbon) organic carbon fractions. Pool-specific radiocarbon work is augmented by the measurement of abundance of compounds such as alkanes, fatty acids and lignin phenols on a subset of samples. Initial results show disparate patterns depending on soil type and in particular soil texture, which could be indicative of various stabilization mechanisms in different soils. Overall, this study provides new insights into the controls of soil organic matter dynamics as related to environmental conditions, in particular in specific sub-pools of carbon.
NASA Astrophysics Data System (ADS)
Alster, Charlotte J.; Koyama, Akihiro; Johnson, Nels G.; Wallenstein, Matthew D.; von Fischer, Joseph C.
2016-06-01
There is compelling evidence that microbial communities vary widely in their temperature sensitivity and may adapt to warming through time. To date, this sensitivity has been largely characterized using a range of models relying on versions of the Arrhenius equation, which predicts an exponential increase in reaction rate with temperature. However, there is growing evidence from laboratory and field studies that observe nonmonotonic responses of reaction rates to variation in temperature, indicating that Arrhenius is not an appropriate model for quantitatively characterizing temperature sensitivity. Recently, Hobbs et al. (2013) developed macromolecular rate theory (MMRT), which incorporates thermodynamic temperature optima as arising from heat capacity differences between isoenzymes. We applied MMRT to measurements of respiration from soils incubated at different temperatures. These soils were collected from three grassland sites across the U.S. Great Plains and reciprocally transplanted, allowing us to isolate the effects of microbial community type from edaphic factors. We found that microbial community type explained roughly 30% of the variation in the CO2 production rate from the labile C pool but that temperature and soil type were most important in explaining variation in labile and recalcitrant C pool size. For six out of the nine soil × inoculum combinations, MMRT was superior to Arrhenius. The MMRT analysis revealed that microbial communities have distinct heat capacity values and temperature sensitivities sometimes independent of soil type. These results challenge the current paradigm for modeling temperature sensitivity of soil C pools and understanding of microbial enzyme dynamics.
Johnson, Jeffrey S.; Yin, Pingbo; O'Connor, Kevin N.
2012-01-01
Amplitude modulation (AM) is a common feature of natural sounds, and its detection is biologically important. Even though most sounds are not fully modulated, the majority of physiological studies have focused on fully modulated (100% modulation depth) sounds. We presented AM noise at a range of modulation depths to awake macaque monkeys while recording from neurons in primary auditory cortex (A1). The ability of neurons to detect partial AM with rate and temporal codes was assessed with signal detection methods. On average, single-cell synchrony was as or more sensitive than spike count in modulation detection. Cells are less sensitive to modulation depth if tested away from their best modulation frequency, particularly for temporal measures. Mean neural modulation detection thresholds in A1 are not as sensitive as behavioral thresholds, but with phase locking the most sensitive neurons are more sensitive, suggesting that for temporal measures the lower-envelope principle cannot account for thresholds. Three methods of preanalysis pooling of spike trains (multiunit, similar to convergence from a cortical column; within cell, similar to convergence of cells with matched response properties; across cell, similar to indiscriminate convergence of cells) all result in an increase in neural sensitivity to modulation depth for both temporal and rate codes. For the across-cell method, pooling of a few dozen cells can result in detection thresholds that approximate those of the behaving animal. With synchrony measures, indiscriminate pooling results in sensitive detection of modulation frequencies between 20 and 60 Hz, suggesting that differences in AM response phase are minor in A1. PMID:22422997
Sireis, W; Rüster, B; Daiss, C; Hourfar, M K; Capalbo, G; Pfeiffer, H-U; Janetzko, K; Goebel, M; Kempf, V A J; Seifried, E; Schmidt, M
2011-10-01
The Paul-Ehrlich-Institute analysed all fatalities due to bacterial infections between 1997 and 2007. Thereafter, the platelet shelf life was reduced to a maximum of 4 days after blood donation because the majority of all cases of severe transfusion-transmitted bacterial infections occurred with day 5 platelets. The current study compares the analytical sensitivity and the diagnostic specificity of four rapid bacterial detection procedures. Nine transfusion-relevant bacterial strains were spiked in pooled platelets or apheresis platelets at a low concentration (10 CFU/bag). Samples were collected after day 3, day 4 and day 5 and investigated by four rapid bacterial detection methods (modified BacT/ALERT, Bactiflow, FACS method and 16s DNA PCR methods). Seven out of nine bacterial strains were adequately detected by BacT/ALERT, Bactiflow and PCR in apheresis platelets and pooled platelets after sample collection at day 3, day 4 and day 5. For three bacterial strains, analytical sensitivity was reduced for the FACS method. Two bacterial strains did not grow under the storage conditions in either pooled or apheresis platelets. A late sample collection on day 3, day 4 or day 5 after blood donation in combination with a rapid bacterial detection method offers a new opportunity to improve blood safety and reduce errors due to sampling., BacT/ALERT, Bactiflow or 16s ID-NAT are feasible for late bacterial screening in platelets may provide data which support the extension of platelet shelf life in Germany to 5 days. © 2011 The Author(s). Vox Sanguinis © 2011 International Society of Blood Transfusion.
Alrajab, Saadah; Youssef, Asser M; Akkus, Nuri I; Caldito, Gloria
2013-09-23
Ultrasonography is being increasingly utilized in acute care settings with expanding applications. Pneumothorax evaluation by ultrasonography is a fast, safe, easy and inexpensive alternative to chest radiographs. In this review, we provide a comprehensive analysis of the current literature comparing ultrasonography and chest radiography for the diagnosis of pneumothorax. We searched English-language articles in MEDLINE, EMBASE and Cochrane Library dealing with both ultrasonography and chest radiography for diagnosis of pneumothorax. In eligible studies that met strict inclusion criteria, we conducted a meta-analysis to evaluate the diagnostic accuracy of pleural ultrasonography in comparison with chest radiography for the diagnosis of pneumothorax. We reviewed 601 articles and selected 25 original research articles for detailed review. Only 13 articles met all of our inclusion criteria and were included in the final analysis. One study used lung sliding sign alone, 12 studies used lung sliding and comet tail signs, and 6 studies searched for lung point in addition to the other two signs. Ultrasonography had a pooled sensitivity of 78.6% (95% CI, 68.1 to 98.1) and a specificity of 98.4% (95% CI, 97.3 to 99.5). Chest radiography had a pooled sensitivity of 39.8% (95% CI, 29.4 to 50.3) and a specificity of 99.3% (95% CI, 98.4 to 100). Our meta-regression and subgroup analyses indicate that consecutive sampling of patients compared to convenience sampling provided higher sensitivity results for both ultrasonography and chest radiography. Consecutive versus nonconsecutive sampling and trauma versus nontrauma settings were significant sources of heterogeneity. In addition, subgroup analysis showed significant variations related to operator and type of probe used. Our study indicates that ultrasonography is more accurate than chest radiography for detection of pneumothorax. The results support the previous investigations in this field, add new valuable information obtained from subgroup analysis, and provide accurate estimates for the performance parameters of both bedside ultrasonography and chest radiography for pneumothorax evaluation.
Discussion on runoff purification technology of highway bridge deck based on water quality safety
NASA Astrophysics Data System (ADS)
Tan, Sheng-guang; Liu, Xue-xin; Zou, Guo-ping; Xiong, Xin-zhu; Tao, Shuang-cheng
2018-06-01
Aiming at the actual problems existing, including a poor purification effect of highway bridge runoff collection and treatment system across sensitive water and necessary manual emergency operation, three kinds of technology, three pools system of bridge runoff purification, the integral pool of bridge runoff purification and ecological planting tank, are put forward by optimizing the structure of purification unit and system setting. At the same time, we come up with an emergency strategy for hazardous material leakage basing on automatic identification and remote control of traffic accidents. On the basis of combining these with the optimized pool structure, sensitive water safety can be guaranteed and water pollution, from directly discharging of bridge runoff, can be decreased. For making up for the shortages of green highway construction technology, the technique has important reference value.
Chenglin, L.; Charpentier, R.R.
2010-01-01
The U.S. Geological Survey procedure for the estimation of the general form of the parent distribution requires that the parameters of the log-geometric distribution be calculated and analyzed for the sensitivity of these parameters to different conditions. In this study, we derive the shape factor of a log-geometric distribution from the ratio of frequencies between adjacent bins. The shape factor has a log straight-line relationship with the ratio of frequencies. Additionally, the calculation equations of a ratio of the mean size to the lower size-class boundary are deduced. For a specific log-geometric distribution, we find that the ratio of the mean size to the lower size-class boundary is the same. We apply our analysis to simulations based on oil and gas pool distributions from four petroleum systems of Alberta, Canada and four generated distributions. Each petroleum system in Alberta has a different shape factor. Generally, the shape factors in the four petroleum systems stabilize with the increase of discovered pool numbers. For a log-geometric distribution, the shape factor becomes stable when discovered pool numbers exceed 50 and the shape factor is influenced by the exploration efficiency when the exploration efficiency is less than 1. The simulation results show that calculated shape factors increase with those of the parent distributions, and undiscovered oil and gas resources estimated through the log-geometric distribution extrapolation are smaller than the actual values. ?? 2010 International Association for Mathematical Geology.
Levesque, Ives; Sled, John G; Narayanan, Sridar; Santos, A Carlos; Brass, Steven D; Francis, Simon J; Arnold, Douglas L; Pike, G Bruce
2005-02-01
To use quantitative magnetization transfer imaging (qMTI) in an investigation of T1-weighted hypointensity observed in clinical magnetic resonance imaging (MRI) scans of multiple sclerosis (MS) patients, which has previously been proposed as a more specific indicator of tissue damage than the more commonly detected T2 hyperintensity. A cross-sectional study of 10 MS patients was performed using qMTI. A total of 60 MTI measurements were collected in each patient at a resolution of 2 x 2 x 7 mm, over a range of saturation pulses. The observed T1 and T2 were also measured. qMT model parameters were estimated using a voxel-by-voxel fit. A total of 65 T2-hyperintense lesions were identified; 53 were also T1 hypointense. In these black holes, the qMTI-derived semisolid pool fraction F correlated negatively with T(1,obs) (r2 = 0.76; P < 0.0001). The water pool absolute size (PDf) showed a weaker correlation with T(1,obs) (positive, r2 = 0.53; P < 0.0001). The magnetization transfer ratio (MTR) showed a similarly strong correlation with F and a weaker correlation with PDf (r2 = 0.18; P < 0.04). T1 increases in chronic black holes strongly correlated with the decline in semisolid pool size, and somewhat less to the confounding effect of edema. MTR was less sensitive than T(1,obs) to liquid pool changes associated with edema. (c) 2005 Wiley-Liss, Inc.
Co-circulation of West Nile virus and distinct insect-specific flaviviruses in Turkey.
Ergünay, Koray; Litzba, Nadine; Brinkmann, Annika; Günay, Filiz; Sarıkaya, Yasemen; Kar, Sırrı; Örsten, Serra; Öter, Kerem; Domingo, Cristina; Erisoz Kasap, Özge; Özkul, Aykut; Mitchell, Luke; Nitsche, Andreas; Alten, Bülent; Linton, Yvonne-Marie
2017-03-20
Active vector surveillance provides an efficient tool for monitoring the presence or spread of emerging or re-emerging vector-borne viruses. This study was undertaken to investigate the circulation of flaviviruses. Mosquitoes were collected from 58 locations in 10 provinces across the Aegean, Thrace and Mediterranean Anatolian regions of Turkey in 2014 and 2015. Following morphological identification, mosquitoes were pooled and screened by nested and real-time PCR assays. Detected viruses were further characterised by sequencing. Positive pools were inoculated onto cell lines for virus isolation. Next generation sequencing was employed for genomic characterisation of the isolates. A total of 12,711 mosquito specimens representing 15 species were screened in 594 pools. Eleven pools (2%) were reactive in the virus screening assays. Sequencing revealed West Nile virus (WNV) in one Culex pipiens (s.l.) pool from Thrace. WNV sequence corresponded to lineage one clade 1a but clustered distinctly from the Turkish prototype isolate. In 10 pools, insect-specific flaviviruses were characterised as Culex theileri flavivirus in 5 pools of Culex theileri and one pool of Cx. pipiens (s.l.), Ochlerotatus caspius flavivirus in two pools of Aedes (Ochlerotatus) caspius, Flavivirus AV-2011 in one pool of Culiseta annulata, and an undetermined flavivirus in one pool of Uranotaenia unguiculata from the Aegean and Thrace regions. DNA forms or integration of the detected insect-specific flaviviruses were not observed. A virus strain, tentatively named as "Ochlerotatus caspius flavivirus Turkey", was isolated from an Ae. caspius pool in C6/36 cells. The viral genome comprised 10,370 nucleotides with a putative polyprotein of 3,385 amino acids that follows the canonical flavivirus polyprotein organisation. Sequence comparisons and phylogenetic analyses revealed the close relationship of this strain with Ochlerotatus caspius flavivirus from Portugal and Hanko virus from Finland. Several conserved structural and amino acid motifs were identified. We identified WNV and several distinct insect-specific flaviviruses during an extensive biosurveillance study of mosquitoes in various regions of Turkey in 2014 and 2015. Ongoing circulation of WNV is revealed, with an unprecedented genetic diversity. A probable replicating form of an insect flavivirus identified only in DNA form was detected.
Aly, Ibrahim; Taher, Eman E; El Nain, Gehan; El Sayed, Hoda; Mohammed, Faten A; Hamad, Rabab S; Bayoumy, Elsayed M
2018-01-01
Nanotechnology is a promising arena for generating new applications in Medicine. To successfully functionalised nanoparticles for a given biomedical application, a wide range of chemical, physical and biological factors have to be taken into account. Silica-coated nanoparticles, (SiO2NP) exhibit substantial diagnostic activity owing to their large surface to volume ratios and crystallographic surface structure. This work aimed to evaluate the advantage of bioconjugation of SiO2NP with PAb against Toxoplasma lyzate antigen (TLA) as an innovative diagnostic method for human toxoplasmosis. This cross-sectional study included 120 individuals, divided into Group I: 70 patients suspected for Toxoplasma gondii based on the presence of clinical manifestation. Group II: 30 patients harboring other parasites than T. gondii Group III: 20 apparently healthy individuals free from toxoplasmosis and other parasitic infections served as negative control. Detection of circulating Toxoplasma antigen was performed by Sandwich ELISA and Nano-sandwich ELISA on sera and pooled urine of human samples. Using Sandwich ELISA, 10 out of 70 suspected Toxoplasma-infected human serum samples showed false negative and 8 out of 30 of other parasites groups were false positive giving 85.7% sensitivity and 84.0% specificity, while the sensitivity and specificity were 78.6% and 70% respectively in urine samples. Using Nano-Sandwich ELISA, 7 out of 70 suspected Toxoplasma-infected human samples showed false negative results and the sensitivity of the assay was 90.0%, while 4 out of 30 of other parasites groups were false positive giving 92.0% specificity, while the sensitivity and specificity were 82.6% and 80% respectively in urine samples. In conclusion, our data demonstrated that loading SiO2 nanoparticles with pAb increased the sensitivity and specificity of Nano-sandwich ELISA for detection of T.gondii antigens in serum and urine samples, thus active (early) and light infections could be easily detected. Copyright © 2017 Elsevier B.V. All rights reserved.
Contrast-Enhanced Ultrasonography in Differential Diagnosis of Benign and Malignant Ovarian Tumors
Qiao, Jing-Jing; Yu, Jing; Yu, Zhe; Li, Na; Song, Chen; Li, Man
2015-01-01
Objective To evaluate the accuracy of contrast-enhanced ultrasonography (CEUS) in differential diagnosis of benign and malignant ovarian tumors. Methods The scientific literature databases PubMed, Cochrane Library and CNKI were comprehensively searched for studies relevant to the use of CEUS technique for differential diagnosis of benign and malignant ovarian cancer. Pooled summary statistics for specificity (Spe), sensitivity (Sen), positive and negative likelihood ratios (LR+/LR−), and diagnostic odds ratio (DOR) and their 95%CIs were calculated. Software for statistical analysis included STATA version 12.0 (Stata Corp, College Station, TX, USA) and Meta-Disc version 1.4 (Universidad Complutense, Madrid, Spain). Results Following a stringent selection process, seven high quality clinical trials were found suitable for inclusion in the present meta-analysis. The 7 studies contained a combined total of 375 ovarian cancer patients (198 malignant and 177 benign). Statistical analysis revealed that CEUS was associated with the following performance measures in differential diagnosis of ovarian tumors: pooled Sen was 0.96 (95%CI = 0.92∼0.98); the summary Spe was 0.91 (95%CI = 0.86∼0.94); the pooled LR+ was 10.63 (95%CI = 6.59∼17.17); the pooled LR− was 0.04 (95%CI = 0.02∼0.09); and the pooled DOR was 241.04 (95% CI = 92.61∼627.37). The area under the SROC curve was 0.98 (95% CI = 0.20∼1.00). Lastly, publication bias was not detected (t = −0.52, P = 0.626) in the meta-analysis. Conclusions Our results revealed the high clinical value of CEUS in differential diagnosis of benign and malignant ovarian tumors. Further, CEUS may also prove to be useful in differential diagnosis at early stages of this disease. PMID:25764442
Comparison of sampling methods used for MRSA-classification of herds with breeding pigs.
Broens, E M; Graat, E A M; Engel, B; van Oosterom, R A A; van de Giessen, A W; van der Wolf, P J
2011-01-27
Since the first report on methicillin resistant Staphylococcus aureus (MRSA) CC398 in pigs, several countries have determined the prevalence of MRSA-positive pig herds using different sampling and laboratory techniques. The objective of the study was to compare three sampling methods for MRSA-classification of herds. Therefore, nasal swabs of pigs and environmental wipes were collected from 147 herds with breeding pigs. Per herd, laboratory examination was done on 10 pools of 6 nasal swabs (NASAL), 5 single environmental wipes (ENVSINGLE) and one pool of 5 environmental wipes (ENVPOOL). Large differences in apparent prevalence of MRSA-positive herds between methods were found: 19.1% for ENVPOOL, 53.1% for ENVSINGLE, and 70.8% for NASAL. Pairwise comparisons of methods resulted in relative sensitivities of 26.9% (ENVPOOL vs. NASAL), 34.6% (ENVPOOL vs. ENVSINGLE), and 72.1% (ENVSINGLE vs. NASAL) with relative specificities of respectively 100%, 98.6% and 93.0%. Cohen's kappa was respectively 0.18, 0.32 and 0.55, thus varying between very poor and moderate agreement. Examination of environmental wipes is an easy and non-invasive method to classify herds for MRSA. The number of environmental wipes needed depends on e.g. required detection limits and within-herd prevalence. In low prevalent herds (e.g. herds with <3 positive pools of nasal swabs), 25 single environmental wipes are required to be 90% sure that MRSA is detected at a detection limit similar to analyzing 10 pools of nasal swabs. Individual analysis of environmental wipes is highly recommended, as pooling 5 environmental samples resulted in a substantial reduction of the apparent prevalence. Copyright © 2010 Elsevier B.V. All rights reserved.
2010-01-01
Prescribed by ANSI Std Z39-18 senescence and thereby prevent radiation- induced stem cell pool exhaustion. Our laboratory has shown that the isofla- vone...genistein transiently arrests the LT-HSC in the G0/ G1 phases of the cell cycle and reduces radiation- induced genotoxicity, senescence, and stem cell pool... induced radiation protection correlated with tran- sient quiescence (increased G0) of the ST-HSC population and prevention of stem cell pool
Impacts of Large-Scale Circulation on Convection: A 2-D Cloud Resolving Model Study
NASA Technical Reports Server (NTRS)
Li, X; Sui, C.-H.; Lau, K.-M.
1999-01-01
Studies of impacts of large-scale circulation on convection, and the roles of convection in heat and water balances over tropical region are fundamentally important for understanding global climate changes. Heat and water budgets over warm pool (SST=29.5 C) and cold pool (SST=26 C) were analyzed based on simulations of the two-dimensional cloud resolving model. Here the sensitivity of heat and water budgets to different sizes of warm and cold pools is examined.
Humoral immune response to Dipylidium caninum infection of stray dogs in Taiwan.
Shin, J W; Liao, W T
2002-04-02
Two kinds of homogeneous proglottid, mature and gravid, of Dipylidium caninum were used as the antigens for immunodiagnosis of canine dipylidiosis in stray dogs in Tainan, Taiwan. The ELISA was performed on 30 serum samples; 24 from dipylidiosis, four from ancylostomosis and two from toxocariosis. The ELISA have specificity and sensitive of 100 and 50% for mature proglottid extract, and 75 and 100%, respectively, for gravid proglottid extract. EITB technique showed two major peptide bands of 94.8 and 97.9kDa were recognized in the sera pool of infected dogs.
Triques, Karine; Piednoir, Elodie; Dalmais, Marion; Schmidt, Julien; Le Signor, Christine; Sharkey, Mark; Caboche, Michel; Sturbois, Bénédicte; Bendahmane, Abdelhafid
2008-04-23
Most enzymatic mutation detection methods are based on the cleavage of heteroduplex DNA by a mismatch-specific endonuclease at mismatch sites and the analysis of the digestion product on a DNA sequencer. Important limitations of these methods are the availability of a mismatch-specific endonuclease, their sensitivity in detecting one allele in pool of DNA, the cost of the analysis and the ease by which the technique could be implemented in a standard molecular biology laboratory. The co-agroinfiltration of ENDO1 and p19 constructs into N. benthamiana leaves allowed high level of transient expression of a mismatch-specific and sensitive endonuclease, ENDO1 from Arabidopsis thaliana. We demonstrate the broad range of uses of the produced enzyme in detection of mutations. In human, we report the diagnosis of the G1691A mutation in Leiden factor-V gene associated with venous thrombosis and the fingerprinting of HIV-1 quasispecies in patients subjected to antiretroviral treatments. In plants, we report the use of ENDO1 system for detection of mutant alleles of Retinoblastoma-related gene by TILLING in Pisum sativum and discovery of natural sequence variations by Eco-TILLING in Arabidopsis thaliana. We introduce a cost-effective tool based on a simplified purification protocol of a mismatch-specific and sensitive endonuclease, ENDO1. Especially, we report the successful applications of ENDO1 in mutation diagnostics in humans, fingerprinting of complex population of viruses, and in TILLING and Eco-TILLING in plants.
47 CFR 61.48 - Transition rules for price cap formula calculations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... percentage of Base Period Price Cap Revenues at the holding company level greater than the industry wide... filing entity is shifted to the CMT basket within price caps. Pooled local switching revenue will not be... section, to pooled elements after the Average Traffic Sensitive Charge reaches the target level. For the...
47 CFR 61.48 - Transition rules for price cap formula calculations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... percentage of Base Period Price Cap Revenues at the holding company level greater than the industry wide... filing entity is shifted to the CMT basket within price caps. Pooled local switching revenue will not be... section, to pooled elements after the Average Traffic Sensitive Charge reaches the target level. For the...
47 CFR 61.48 - Transition rules for price cap formula calculations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... percentage of Base Period Price Cap Revenues at the holding company level greater than the industry wide... filing entity is shifted to the CMT basket within price caps. Pooled local switching revenue will not be... section, to pooled elements after the Average Traffic Sensitive Charge reaches the target level. For the...
Nansseu, Jobert Richie N; Fokom-Domgue, Joël; Noubiap, Jean Jacques N; Balti, Eric V; Sobngwi, Eugène; Kengne, André Pascal
2015-05-15
Fructosamine is a marker of glucose control reflecting the average glycaemic level over the preceding 2-3 weeks. Fructosamine has not gained as much popularity as glycated haemoglobin (HbA1c) for diabetes mellitus (DM) control monitoring, and the related underlying reasons remain unclear. We aim to search for and summarise available evidence on the accuracy of fructosamine measurements to diagnose and monitor DM. This systematic review will include randomised control trials, controlled before-and-after studies, time series designs, cohort studies, case-control studies and cross-sectional surveys reporting the diagnosis and/or monitoring of DM (type 1 DM, type 2 DM and gestational DM) with fructosamine compared with other measures of glycaemia (fasting glucose, oral glucose tolerance test, random glucose, HbA1c), without any language restriction. We will perform electronic searches in PubMed, Scopus and other databases, supplemented with manual searches. Articles published from 1 January 1980 to 30 June 2015 will be eligible for inclusion in this review. Two authors will independently screen, select studies, extract data and assess the risk of bias with discrepancies resolved by consensus. We will assess clinical heterogeneity by examining the types of interventions and outcomes in each study, and pool studies judged to be clinically homogeneous. We will also assess statistical heterogeneity using the χ(2) test of homogeneity and quantify it using the I(2) statistic. Absolute accuracy measures (sensitivity, specificity) will be pooled in a bivariate random-effects model, allowing for intersetting variability. Negative and positive predictive values will be computed for fructosamine, compared with another measure of glycaemia from the pooled estimates of sensitivity and specificity, using Bayes' theorem. This systematic review will use data from published studies and does not require ethics approval. Findings will be published in a peer-reviewed journal and presented at scientific conferences. PROSPERO (ID=CRD42015015930). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Suzana, Shirly; Ninan, Marilyn M; Gowri, Mahasampath; Venkatesh, Krishnan; Rupali, Priscilla; Michael, Joy S
2016-03-01
The Xpert MTB/Rif, with a detection limit of 131 CFU/ml, plays a valuable role in the diagnosis of extrapulmonary tuberculosis, both susceptible and resistant. This study aims at evaluating the Xpert MTB/Rif for the same, at a tertiary care centre in south India, assessing it against both culture and a composite gold standard (CGS). We tested consecutive samples from patients suspected of extrapulmonary tuberculosis with Xpert MTB/Rif, evaluated its sensitivity and specificity against solid and/or liquid culture and CGS. An individual analysis of different sample types (tissue biopsies, fluids, pus, lymph node biopsies and CSF) given an adequate sample size, against both culture and CGS, was also performed. In total, 494 samples were analysed against culture. Compared to culture, the sensitivity of Xpert MTB/Rif was 89% (95% CI 0.81-0.94) and its specificity was 74% (95% CI 0.70-0.78). When Xpert MTB/Rif was compared to the CGS, pooled sensitivity was 62% (95% CI 0.56-0.67) and specificity was 100% (95% CI 0.91-1.00). This assay performs better than the currently available conventional laboratory methods. The rapidity with which results are obtained is an added advantage, and its integration into a routine diagnostic protocol must be considered. © 2015 John Wiley & Sons Ltd.
Jurek, Anne M; Maldonado, George; Greenland, Sander
2013-03-01
Special care must be taken when adjusting for outcome misclassification in case-control data. Basic adjustment formulas using either sensitivity and specificity or predictive values (as with external validation data) do not account for the fact that controls are sampled from a much larger pool of potential controls. A parallel problem arises in surveys and cohort studies in which participation or loss is outcome related. We review this problem and provide simple methods to adjust for outcome misclassification in case-control studies, and illustrate the methods in a case-control birth certificate study of cleft lip/palate and maternal cigarette smoking during pregnancy. Adjustment formulas for outcome misclassification that ignore case-control sampling can yield severely biased results. In the data we examined, the magnitude of error caused by not accounting for sampling is small when population sensitivity and specificity are high, but increases as (1) population sensitivity decreases, (2) population specificity decreases, and (3) the magnitude of the differentiality increases. Failing to account for case-control sampling can result in an odds ratio adjusted for outcome misclassification that is either too high or too low. One needs to account for outcome-related selection (such as case-control sampling) when adjusting for outcome misclassification using external information. Copyright © 2013 Elsevier Inc. All rights reserved.
A computational proposal for designing structured RNA pools for in vitro selection of RNAs.
Kim, Namhee; Gan, Hin Hark; Schlick, Tamar
2007-04-01
Although in vitro selection technology is a versatile experimental tool for discovering novel synthetic RNA molecules, finding complex RNA molecules is difficult because most RNAs identified from random sequence pools are simple motifs, consistent with recent computational analysis of such sequence pools. Thus, enriching in vitro selection pools with complex structures could increase the probability of discovering novel RNAs. Here we develop an approach for engineering sequence pools that links RNA sequence space regions with corresponding structural distributions via a "mixing matrix" approach combined with a graph theory analysis. We define five classes of mixing matrices motivated by covariance mutations in RNA; these constructs define nucleotide transition rates and are applied to chosen starting sequences to yield specific nonrandom pools. We examine the coverage of sequence space as a function of the mixing matrix and starting sequence via clustering analysis. We show that, in contrast to random sequences, which are associated only with a local region of sequence space, our designed pools, including a structured pool for GTP aptamers, can target specific motifs. It follows that experimental synthesis of designed pools can benefit from using optimized starting sequences, mixing matrices, and pool fractions associated with each of our constructed pools as a guide. Automation of our approach could provide practical tools for pool design applications for in vitro selection of RNAs and related problems.
Constructed Pools-and-Riffles: Application and Assessment in Illinois.
NASA Astrophysics Data System (ADS)
Day, D. M.; Dodd, H. R.; Carney, D. A.; Holtrop, A. M.; Whiles, M. R.; White, B.; Roseboom, D.; Kinney, W.; Keefer, L. L.; Beardsley, J.
2005-05-01
The diversity of Illinois' streams provides a broad range of conditions, and thus a variety of restoration techniques may be required to adequately compensate for watershed alterations. Resource management agencies and research institutions in the state have collaborated on a variety of applied research initiatives to assess the efficacy of various stream protection and restoration techniques. Constructed pool-and-riffle structures have received significant attention because they tend to address watershed processes (i.e., channel evolution model) and may benefit biotic communities and processes along with physical habitat. Constructed pools-and-riffles have been applied primarily to address geomorphic instability, yet understanding biological responses can provide further rationale for their use and design specifications. In three stream systems around the state, fish were collected pre- and post- installation of structures, using primarily electrofishing techniques (e.g., electric seine & backpack). In general, within the first five years after installation, changes in fish communities have included a shift from high-abundance, small cyprinid-dominated assemblages to low-density Centrarchidae and Catostomidae assemblages. Changes in macro invertebrates at selected sites included increases in filter feeders and sensitive taxa such as the Ephemeroptera, Plecoptera, and Trichoptera (EPT). Ongoing assessments will be critical for understanding long-term influences on stream ecosystem structure and function.
Henry, Brandon Michael; Roy, Joyeeta; Ramakrishnan, Piravin Kumar; Vikse, Jens; Tomaszewski, Krzysztof A; Walocha, Jerzy A
2016-07-01
Several studies have explored the use of serum procalcitonin (PCT) in differentiating between bacterial and viral etiologies in children with suspected meningitis. We pooled these studies into a meta-analysis to determine the PCT diagnostic accuracy. All major databases were searched through March 2015. No date or language restrictions were applied. Eight studies (n = 616 pediatric patients) were included. Serum PCT assay was found to be very accurate for differentiating the etiology of pediatric meningitis with pooled sensitivity and specificity of 0.96 (95% CI = 0.92-0.98) and 0.89 (95% CI = 0.86-0.92), respectively. The pooled positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio (DOR), and area under the curve (AUC) for PCT were 7.5 (95% CI = 5.6-10.1), 0.08(95% CI = 0.04-0.14), 142.3 (95% CI = 59.5-340.4), and 0.97 (SE = 0.01), respectively. In 6 studies, PCT was found to be superior than CRP, whose DOR was only 16.7 (95%CI = 8.8-31.7). Our meta-analysis demonstrates that serum PCT assay is a highly accurate and powerful test for rapidly differentiating between bacterial and viral meningitis in children. © The Author(s) 2015.
Brault, Aaron C; Fang, Ying; Reisen, William K
2015-05-01
Following the introduction of West Nile virus into California during the summer of 2003, public health and vector control programs expanded surveillance efforts and were in need of diagnostics capable of rapid, sensitive, and specific detection of arbovirus infections of mosquitoes to inform decision support for intervention. Development of a multiplex TaqMan or real-time semiquantitative reverse transcription polymerase chain reaction (RT-PCR) assay in which three virus specific primer-probe sets were used in the same reaction is described herein for the detection of western equine encephalomyelitis, St. Louis encephalitis and West Nile viral RNA. Laboratory validation and field data from 10 transmission seasons are reported. The comparative sensitivity and specificity of this multiplex assay to singleplex RT-PCR as well as an antigen detection (rapid analyte measurement platform) and standard plaque assays indicate this assay to be rapid and useful in providing mosquito infection data to estimate outbreak risk. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
GABAergic neurons in ferret visual cortex participate in functionally specific networks
Wilson, Daniel E.; Smith, Gordon B.; Jacob, Amanda; Walker, Theo; Dimidschstein, Jordane; Fishell, Gord J.; Fitzpatrick, David
2017-01-01
Summary Functional circuits in the visual cortex require the coordinated activity of excitatory and inhibitory neurons. Molecular genetic approaches in the mouse have led to the ‘local nonspecific pooling principle’ of inhibitory connectivity, in which inhibitory neurons are untuned for stimulus features due to the random pooling of local inputs. However, it remains unclear whether this principle generalizes to species with a columnar organization of feature selectivity such as carnivores, primates, and humans. Here we use virally-mediated GABAergic-specific GCaMP6f expression to demonstrate that inhibitory neurons in ferret visual cortex respond robustly and selectively to oriented stimuli. We find that the tuning of inhibitory neurons is inconsistent with the local non-specific pooling of excitatory inputs, and that inhibitory neurons exhibit orientation-specific noise correlations with local and distant excitatory neurons. These findings challenge the generality of the non-specific pooling principle for inhibitory neurons, suggesting different rules for functional excitatory-inhibitory interactions in non-murine species. PMID:28279352
Accuracy of early detection of colorectal tumours by stool methylation markers: A meta-analysis
Zhang, Hu; Qi, Jian; Wu, Ya-Qiong; Zhang, Ping; Jiang, Jun; Wang, Qi-Xian; Zhu, You-Qing
2014-01-01
AIM: To evaluate the accuracy of methylation of genes in stool samples for diagnosing colorectal tumours. METHODS: Electronic databases including PubMed, Web of Science, Chinese Journals Full-Text Database and Wanfang Journals Full-Text Database were searched to find relevant original articles about methylated genes to be used in diagnosing colorectal tumours. A quality assessment of diagnostic accuracy studies tool (QADAS) was used to evaluate the quality of the included articles, and the Meta-disc 1.4 and SPSS 13.0 software programs were used for data analysis. RESULTS: Thirty-seven articles met the inclusion criteria, and 4484 patients were included. The sensitivity and specificity for the detection of colorectal cancer (CRC) were 73% (95%CI: 71%-75%) and 92% (95%CI: 90%-93%), respectively. For adenoma, the sensitivity and specificity were 51% (95%CI: 47%-54%) and 92% (95%CI: 90%-93%), respectively. Pooled diagnostic performance of SFRP2 methylation for CRC provided the following results: the sensitivity was 79% (95%CI: 75%-82%), the specificity was 93% (95%CI: 90%-96%), the diagnostic OR was 47.57 (95%CI: 20.08-112.72), the area under the curve was 0.9565. Additionally, the results of accuracy of SFRP2 methylation for detecting colorectal adenomas were as follows: sensitivity was 43% (95%CI: 38%-49%), specificity was 94% (95%CI: 91%-97%), the diagnostic OR was 11.06 (95%CI: 5.77-21.18), and the area under the curve was 0.9563. CONCLUSION: Stool-based DNA testing may be useful for noninvasively diagnosing colorectal tumours and SFRP2 methylation is a promising marker that has great potential in early CRC diagnosis. PMID:25320544
Walter, Fiona M; Prevost, A Toby; Birt, Linda; Grehan, Nicola; Restarick, Kathy; Morris, Helen C; Sutton, Stephen; Rose, Peter; Downing, Sarah; Emery, Jon D
2013-01-01
Background Family history is an important risk factor for many common chronic diseases, but it remains underutilised for diagnostic assessment and disease prevention in routine primary care. Aim To develop and validate a brief self-completed family history questionnaire (FHQ) for systematic primary care assessment for family history of diabetes, ischaemic heart disease, breast cancer, and colorectal cancer. Design and setting Two-stage diagnostic validation study in 10 general practices in eastern England. Method Participants aged 18–50 years were identified via random sampling from electronic searches of general practice records. Participants completed a FHQ then had a three-generational ‘gold standard’ pedigree taken, to determine disease risk category. In stage 1, the FHQ comprised 12 items; in stage 2 the shorter 6-item FHQ was validated against the same ‘gold standard’. Results There were 1147 participants (stage 1: 618; stage 2: 529). Overall, 32% were at increased risk of one or more marker conditions (diabetes 18.9%, ischaemic heart disease 13.3%, breast cancer 6.2%, colorectal cancer 2.2%). The shorter 6-item FHQ performed very well for all four conditions: pooled data from both stages show diabetes, sensitivity = 98%, specificity = 94%; ischaemic heart disease, sensitivity = 93%, specificity = 81%; breast cancer, sensitivity = 81%, specificity = 83%; colorectal cancer, sensitivity = 96%, specificity = 88%, with an area under the receiver operating characteristic curve of 0.90 for males and 0.89 for females. Conclusion This brief self-completed FHQ shows good diagnostic accuracy for identifying people at higher risk of four common chronic diseases. It could be used in routine primary care to identify patients who would be most likely to benefit from a more detailed pedigree and risk assessment, and consequent management strategies. PMID:23735410
Accuracy of early detection of colorectal tumours by stool methylation markers: a meta-analysis.
Zhang, Hu; Qi, Jian; Wu, Ya-Qiong; Zhang, Ping; Jiang, Jun; Wang, Qi-Xian; Zhu, You-Qing
2014-10-14
To evaluate the accuracy of methylation of genes in stool samples for diagnosing colorectal tumours. Electronic databases including PubMed, Web of Science, Chinese Journals Full-Text Database and Wanfang Journals Full-Text Database were searched to find relevant original articles about methylated genes to be used in diagnosing colorectal tumours. A quality assessment of diagnostic accuracy studies tool (QADAS) was used to evaluate the quality of the included articles, and the Meta-disc 1.4 and SPSS 13.0 software programs were used for data analysis. Thirty-seven articles met the inclusion criteria, and 4484 patients were included. The sensitivity and specificity for the detection of colorectal cancer (CRC) were 73% (95%CI: 71%-75%) and 92% (95%CI: 90%-93%), respectively. For adenoma, the sensitivity and specificity were 51% (95%CI: 47%-54%) and 92% (95%CI: 90%-93%), respectively. Pooled diagnostic performance of SFRP2 methylation for CRC provided the following results: the sensitivity was 79% (95%CI: 75%-82%), the specificity was 93% (95%CI: 90%-96%), the diagnostic OR was 47.57 (95%CI: 20.08-112.72), the area under the curve was 0.9565. Additionally, the results of accuracy of SFRP2 methylation for detecting colorectal adenomas were as follows: sensitivity was 43% (95%CI: 38%-49%), specificity was 94% (95%CI: 91%-97%), the diagnostic OR was 11.06 (95%CI: 5.77-21.18), and the area under the curve was 0.9563. Stool-based DNA testing may be useful for noninvasively diagnosing colorectal tumours and SFRP2 methylation is a promising marker that has great potential in early CRC diagnosis.
Clearance of the cervical spine in clinically unevaluable trauma patients.
Halpern, Casey H; Milby, Andrew H; Guo, Wensheng; Schuster, James M; Gracias, Vicente H; Stein, Sherman C
2010-08-15
Meta-analytic costeffectiveness analysis. Our goal was to compare the results of different management strategies for trauma patients in whom the cervical spine was not clinically evaluable due to impaired consciousness, endotracheal intubation, or painful distracting injuries. We performed a structured literature review related to cervical spine trauma, radiographic clearance techniques (plain radiography, flexion/extension, CT, and MRI), and complications associated with semirigid collar use. Meta-analytic techniques were used to pool data from multiple sources to calculate pooled mean estimates of sensitivities and specificities of imaging techniques for cervical spinal clearance, rates of complications from various clearance strategies and from empirical use of semirigid collars. A decision analysis model was used to compare outcomes and costs among these strategies. Slightly more than 7.5% of patients who are clinically unevaluable have cervical spine injuries, and 42% of these injuries are associated with spinal instability. Sensitivity of plain radiography or fluoroscopy for spinal clearance was 57% (95% CI: 57%-60%). Sensitivities for CT and MRI alone were 83% (82%-84%) and 87% (84%-89%), respectively. Complications associated with collar use ranged from 1.3% (2 days) to 7.1% (10 days) but were usually minor and short-lived. Quadriplegia resulting from spinal instability missed by a clearance test had enormous impacts on longevity, quality of life, and costs. These impacts overshadowed the effects of prolonged collar application, even when the incidence of quadriplegia was extremely low. As currently used, neuroimaging studies for cervical spinal clearance in clinically unevaluable patients are not cost-effective compared with empirical immobilization in a semirigid collar.
Wnt Signaling Specifies Anteroposterior Progenitor Zone Identity in the Drosophila Visual Center.
Suzuki, Takumi; Trush, Olena; Yasugi, Tetsuo; Takayama, Rie; Sato, Makoto
2016-06-15
During brain development, various types of neuronal populations are produced from different progenitor pools to produce neuronal diversity that is sufficient to establish functional neuronal circuits. However, the molecular mechanisms that specify the identity of each progenitor pool remain obscure. Here, we show that Wnt signaling is essential for the specification of the identity of posterior progenitor pools in the Drosophila visual center. In the medulla, the largest component of the visual center, different types of neurons are produced from two progenitor pools: the outer proliferation center (OPC) and glial precursor cells (GPCs; also known as tips of the OPC). We found that OPC-type neurons are produced from the GPCs at the expense of GPC-type neurons when Wnt signaling is suppressed in the GPCs. In contrast, GPC-type neurons are ectopically induced when Wnt signaling is ectopically activated in the OPC. These results suggest that Wnt signaling is necessary and sufficient for the specification of the progenitor pool identity. We also found that Homothorax (Hth), which is temporally expressed in the OPC, is ectopically induced in the GPCs by suppression of Wnt signaling and that ectopic induction of Hth phenocopies the suppression of Wnt signaling in the GPCs. Thus, Wnt signaling is involved in regionalization of the fly visual center through the specification of the progenitor pool located posterior to the medulla by suppressing Hth expression. Brain consists of considerably diverse neurons of different origins. In mammalian brain, excitatory and inhibitory neurons derive from the dorsal and ventral telencephalon, respectively. Multiple progenitor pools also contribute to the neuronal diversity in fly brain. However, it has been unclear how differences between these progenitor pools are established. Here, we show that Wnt signaling, an evolutionarily conserved signaling, is involved in the process that establishes the differences between these progenitor pools. Because β-catenin signaling, which is under the control of Wnt ligands, specifies progenitor pool identity in the developing mammalian thalamus, Wnt signaling-mediated specification of progenitor pool identity may be conserved in insect and mammalian brains. Copyright © 2016 the authors 0270-6474/16/366503-11$15.00/0.
Suzuki, Takumi; Sato, Makoto
2017-11-15
Diversification of neuronal types is key to establishing functional variations in neural circuits. The first critical step to generate neuronal diversity is to organize the compartmental domains of developing brains into spatially distinct neural progenitor pools. Neural progenitors in each pool then generate a unique set of diverse neurons through specific spatiotemporal specification processes. In this review article, we focus on an additional mechanism, 'inter-progenitor pool wiring', that further expands the diversity of neural circuits. After diverse types of neurons are generated in one progenitor pool, a fraction of these neurons start migrating toward a remote brain region containing neurons that originate from another progenitor pool. Finally, neurons of different origins are intermingled and eventually form complex but precise neural circuits. The developing cerebral cortex of mammalian brains is one of the best examples of inter-progenitor pool wiring. However, Drosophila visual system development has revealed similar mechanisms in invertebrate brains, suggesting that inter-progenitor pool wiring is an evolutionarily conserved strategy that expands neural circuit diversity. Here, we will discuss how inter-progenitor pool wiring is accomplished in mammalian and fly brain systems. Copyright © 2017 Elsevier Inc. All rights reserved.
Yo, Chia-Hung; Lee, Si-Huei; Chang, Shy-Shin; Lee, Matthew Chien-Hung; Lee, Chien-Chang
2014-01-01
Objectives We performed a systematic review and meta-analysis of studies on high-sensitivity C-reactive protein (hs-CRP) assays to see whether these tests are predictive of atrial fibrillation (AF) recurrence after cardioversion. Design Systematic review and meta-analysis. Data sources PubMed, EMBASE and Cochrane databases as well as a hand search of the reference lists in the retrieved articles from inception to December 2013. Study eligibility criteria This review selected observational studies in which the measurements of serum CRP were used to predict AF recurrence. An hs-CRP assay was defined as any CRP test capable of measuring serum CRP to below 0.6 mg/dL. Primary and secondary outcome measures We summarised test performance characteristics with the use of forest plots, hierarchical summary receiver operating characteristic curves and bivariate random effects models. Meta-regression analysis was performed to explore the source of heterogeneity. Results We included nine qualifying studies comprising a total of 347 patients with AF recurrence and 335 controls. A CRP level higher than the optimal cut-off point was an independent predictor of AF recurrence after cardioversion (summary adjusted OR: 3.33; 95% CI 2.10 to 5.28). The estimated pooled sensitivity and specificity for hs-CRP was 71.0% (95% CI 63% to 78%) and 72.0% (61% to 81%), respectively. Most studies used a CRP cut-off point of 1.9 mg/L to predict long-term AF recurrence (77% sensitivity, 65% specificity), and 3 mg/L to predict short-term AF recurrence (73% sensitivity, 71% specificity). Conclusions hs-CRP assays are moderately accurate in predicting AF recurrence after successful cardioversion. PMID:24556243
Simoneau, Gabrielle; Levis, Brooke; Cuijpers, Pim; Ioannidis, John P A; Patten, Scott B; Shrier, Ian; Bombardier, Charles H; de Lima Osório, Flavia; Fann, Jesse R; Gjerdingen, Dwenda; Lamers, Femke; Lotrakul, Manote; Löwe, Bernd; Shaaban, Juwita; Stafford, Lesley; van Weert, Henk C P M; Whooley, Mary A; Wittkampf, Karin A; Yeung, Albert S; Thombs, Brett D; Benedetti, Andrea
2017-11-01
Individual patient data (IPD) meta-analyses are increasingly common in the literature. In the context of estimating the diagnostic accuracy of ordinal or semi-continuous scale tests, sensitivity and specificity are often reported for a given threshold or a small set of thresholds, and a meta-analysis is conducted via a bivariate approach to account for their correlation. When IPD are available, sensitivity and specificity can be pooled for every possible threshold. Our objective was to compare the bivariate approach, which can be applied separately at every threshold, to two multivariate methods: the ordinal multivariate random-effects model and the Poisson correlated gamma-frailty model. Our comparison was empirical, using IPD from 13 studies that evaluated the diagnostic accuracy of the 9-item Patient Health Questionnaire depression screening tool, and included simulations. The empirical comparison showed that the implementation of the two multivariate methods is more laborious in terms of computational time and sensitivity to user-supplied values compared to the bivariate approach. Simulations showed that ignoring the within-study correlation of sensitivity and specificity across thresholds did not worsen inferences with the bivariate approach compared to the Poisson model. The ordinal approach was not suitable for simulations because the model was highly sensitive to user-supplied starting values. We tentatively recommend the bivariate approach rather than more complex multivariate methods for IPD diagnostic accuracy meta-analyses of ordinal scale tests, although the limited type of diagnostic data considered in the simulation study restricts the generalization of our findings. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Rambaud-Althaus, Clotilde; Althaus, Fabrice; Genton, Blaise; D'Acremont, Valérie
2015-04-01
Pneumonia is the biggest cause of deaths in young children in developing countries, but early diagnosis and intervention can effectively reduce mortality. We aimed to assess the diagnostic value of clinical signs and symptoms to identify radiological pneumonia in children younger than 5 years and to review the accuracy of WHO criteria for diagnosis of clinical pneumonia. We searched Medline (PubMed), Embase (Ovid), the Cochrane Database of Systematic Reviews, and reference lists of relevant studies, without date restrictions, to identify articles assessing clinical predictors of radiological pneumonia in children. Selection was based on: design (diagnostic accuracy studies), target disease (pneumonia), participants (children aged <5 years), setting (ambulatory or hospital care), index test (clinical features), and reference standard (chest radiography). Quality assessment was based on the 2011 Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria. For each index test, we calculated sensitivity and specificity and, when the tests were assessed in four or more studies, calculated pooled estimates with use of bivariate model and hierarchical summary receiver operation characteristics plots for meta-analysis. We included 18 articles in our analysis. WHO-approved signs age-related fast breathing (six studies; pooled sensitivity 0·62, 95% CI 0·26-0·89; specificity 0·59, 0·29-0·84) and lower chest wall indrawing (four studies; 0·48, 0·16-0·82; 0·72, 0·47-0·89) showed poor diagnostic performance in the meta-analysis. Features with the highest pooled positive likelihood ratios were respiratory rate higher than 50 breaths per min (1·90, 1·45-2·48), grunting (1·78, 1·10-2·88), chest indrawing (1·76, 0·86-3·58), and nasal flaring (1·75, 1·20-2·56). Features with the lowest pooled negative likelihood ratio were cough (0·30, 0·09-0·96), history of fever (0·53, 0·41-0·69), and respiratory rate higher than 40 breaths per min (0·43, 0·23-0·83). Not one clinical feature was sufficient to diagnose pneumonia definitively. Combination of clinical features in a decision tree might improve diagnostic performance, but the addition of new point-of-care tests for diagnosis of bacterial pneumonia would help to attain an acceptable level of accuracy. Swiss National Science Foundation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ajuied, Adil; McGarvey, Ciaran P; Harb, Ziad; Smith, Christian C; Houghton, Russell P; Corbett, Steven A
2018-05-01
Various protocols exist for magnetic resonance arthrogram (MRA) of the shoulder, including 3D isotropic scanning and positioning in neutral (2D neutral MRA), or abduction-external-rotation (ABER). MRA does not improve diagnostic accuracy for labral tears when compared to magnetic resonance imaging (MRI) performed using 3-Tesla (3T) magnets. Systematic review of the Cochrane, MEDLINE, and PubMed databases according to PRISMA guidelines. Included studies compared 3T MRI or 3T MRA (index tests) to arthroscopic findings (reference test). Methodological appraisal performed using QUADAS-2. Pooled sensitivity and specificity were calculated. Ten studies including 929 patients were included. Index test bias and applicability were a concern in the majority of studies. The use of arthroscopy as the reference test raised concern of verification bias in all studies. For anterior labral lesions, 3T MRI was less sensitive (0.83 vs. 0.87 p = 0.083) than 3T 2D neutral MRA. Compared to 3T 2D neutral MRA, both 3T 3D Isotropic MRA and 3T ABER MRA significantly improved sensitivity (0.87 vs. 0.95 vs. 0.94). For SLAP lesions, 3T 2D neutral MRA was of similar sensitivity to 3T MRI (0.84 vs. 0.83, p = 0.575), but less specific (0.99 vs. 0.92 p < 0.0001). For posterior labral lesions, 3T 2D neutral MRA had greater sensitivity than 3T 3D Isotropic MRA and 3T MRI (0.90 vs. 0.83 vs. 0.83). At 3-T, MRA improved sensitivity for diagnosis of anterior and posterior labral lesions, but reduced specificity in diagnosis of SLAP tears. 3T MRA with ABER positioning further improved sensitivity in diagnosis of anterior labral tears. IV.
Jenvey, Caitlin J; Reichel, Michael P; Cockcroft, Peter D
2015-03-01
Due to relatively high concentrations of immunoglobulins, colostrum has the potential to improve the sensitivity of diagnostic tests for diseases in pigs when compared with serum. It is possible that colostrum could improve the sensitivity of the antibody enzyme-linked immunosorbent assay (ELISA) compared with serum. Colostrum is also essential for piglets, providing protection against infections in the first few weeks and months of life. The sensitivity of 2 commercially available ELISAs, one for the detection of Erysipelothrix rhusiopathiae and the second for Mycoplasma hyopneumoniae antibodies, when used with sow colostrum in comparison with serum was investigated. The correlation of maternal E. rhusiopathiae- and M. hyopneumoniae-specific antibody levels with specific-antibody serum levels in the piglet was also determined. The sensitivity was defined as the proportion of vaccinated sows that were correctly identified as vaccinated at a given cutoff point. The true disease status of the sows with regard to the 2 infections was unknown. Blood and colostrum samples were collected from 20 sows, 10 primiparous and 10 multiparous, and blood samples were also collected from the piglets of each sow, 48-72 hr post-farrowing. The sensitivities of both ELISAs were significantly improved when using colostrum compared with serum. Sow serum and colostrum optical density (OD) values were significantly correlated. The mean sow OD values for serum for E. rhusiopathiae and M. hyopneumoniae and colostrum for E. rhusiopathiae were significantly correlated with piglet serum OD levels. If the improved sensitivity of colostrum can be demonstrated in infected animals, this will increase the ability of the test to identify infected animals using both individual and pooled colostrum. Testing serum and/or colostrum using ELISA can be useful predictors of piglet disease-specific OD values. © 2015 The Author(s).
Hu, Peilei; Bai, Liqiong; Liu, Fengping; Ou, Xichao; Zhang, Zhiying; Yi, Songlin; Chen, Zhongnan; Gong, Daofang; Liu, Binbin; Guo, Jingwei; Tan, Yunhong
2014-01-01
The Xpert MTB/RIF showed high sensitivity and specificity in previous studies carried out in different epidemiological and geographical settings and patient populations in high-burden tuberculosis (TB) countries. However, there were little data obtained by validation or demonstration study of the assay in China. In this study, the performance of Xpert MTB/RIF was investigated in two county-level laboratories in Hunan Province, China. Consecutive patients with suspected pulmonary tuberculosis (PTB) and suspicion for multidrug-resistant tuberculosis (MDR-TB) were enrolled. For each patient suspected to have PTB, three sputum specimens (one spot sputum, one night sputum, and one morning sputum) were collected and each sputum was tested with smear microscopy, Löwenstein-Jensen (LJ) culture, and Xpert MTB/RIF test. For comparison across subgroups and testing methods, 95% confidence intervals were calculated. All analyses were done with SPSS 16.0, and P < 0.05 was regarded as significant. For case detection, the sensitivity of Xpert MTB/RIF was 100% for smear- and culture-positive TB and 88.6% for smear-negative and culture-positive TB; the overall sensitivity was 94.5% for all culture-positive patients. The specificity was 99.8%. The sensitivity of Xpert MTB/RIF assay was 22.0% in clinical TB patients and the specificity reached 100.0% in the group of patients who are infected with nontuberculous mycobacteria. For the detection of rifampin resistance, the sensitivity of MTB/RIF RIF-resistance detection was 92.9%, and the specificity was 98.7%. Of the 26 Xpert MTB/RIF-positive and RIF-resistant patients confirmed by LJ proportion tests, 20 (76.9%) patients were infected by MDR-TB. The Xpert MTB/RIF assay is a highly sensitive and specific method for diagnosis of TB and RIF resistance, which will enable it to have the potential to be used in county-level laboratories and lead to the reduction of the infectious pool and improvements in TB control in China. Further evaluations in county-level laboratories for implementing the assay are still required.
Diagnostic value of 3D time-of-flight MRA in trigeminal neuralgia.
Cai, Jing; Xin, Zhen-Xue; Zhang, Yu-Qiang; Sun, Jie; Lu, Ji-Liang; Xie, Feng
2015-08-01
The aim of this meta-analysis was to evaluate the diagnostic value of 3D time-of-flight magnetic resonance angiography (3D-TOF-MRA) in trigeminal neuralgia (TN). Relevant studies were identified by computerized database searches supplemented by manual search strategies. The studies were included in accordance with stringent inclusion and exclusion criteria. Following a multistep screening process, high quality studies related to the diagnostic value of 3D-TOF-MRA in TN were selected for meta-analysis. Statistical analyses were conducted using Statistical Analysis Software (version 8.2; SAS Institute, Cary, NC, USA) and Meta Disc (version 1.4; Unit of Clinical Biostatistics, Ramon y Cajal Hospital, Madrid, Spain). For the present meta-analysis, we initially retrieved 95 studies from database searches. A total of 13 studies were eventually enrolled containing a combined total of 1084 TN patients. The meta-analysis results demonstrated that the sensitivity and specificity of the diagnostic value of 3D-TOF-MRA in TN were 95% (95% confidence interval [CI] 0.93-0.96) and 77% (95% CI 0.66-0.86), respectively. The pooled positive likelihood ratio and negative likelihood ratio were 2.72 (95% CI 1.81-4.09) and 0.08 (95% CI 0.06-0.12), respectively. The pooled diagnostic odds ratio of 3D-TOF-MRA in TN was 52.92 (95% CI 26.39-106.11), and the corresponding area under the curve in the summary receiver operating characteristic curve based on the 3D-TOF-MRA diagnostic image of observers was 0.9695 (standard error 0.0165). Our results suggest that 3D-TOF-MRA has excellent sensitivity and specificity as a diagnostic tool for TN, and that it can accurately identify neurovascular compression in TN patients. Copyright © 2015 Elsevier Ltd. All rights reserved.
Liou, Kevin; Negishi, Kazuaki; Ho, Suyen; Russell, Elizabeth A; Cranney, Greg; Ooi, Sze-Yuan
2016-08-01
Global longitudinal strain (GLS) is well validated and has important applications in contemporary clinical practice. The aim of this analysis was to evaluate the accuracy of resting peak GLS in the diagnosis of obstructive coronary artery disease (CAD). A systematic literature search was performed through July 2015 using four databases. Data were extracted independently by two authors and correlated before analyses. Using a random-effect model, the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and summary area under the curve for GLS were estimated with their respective 95% CIs. Screening of 1,669 articles yielded 10 studies with 1,385 patients appropriate for inclusion in the analysis. The mean age and left ventricular ejection fraction were 59.9 years and 61.1%. On the whole, 54.9% and 20.9% of the patients had hypertension and diabetes, respectively. Overall, abnormal GLS detected moderate to severe CAD with a pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of 74.4%, 72.1%, 2.9, and 0.35 respectively. The area under the curve and diagnostic odds ratio were 0.81 and 8.5. The mean values of GLS for those with and without CAD were -16.5% (95% CI, -15.8% to -17.3%) and -19.7% (95% CI, -18.8% to -20.7%), respectively. Subgroup analyses for patients with severe CAD and normal left ventricular ejection fractions yielded similar results. Current evidence supports the use of GLS in the detection of moderate to severe obstructive CAD in symptomatic patients. GLS may complement existing diagnostic algorithms and act as an early adjunctive marker of cardiac ischemia. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
Quantification of in vivo pH-weighted amide proton transfer (APT) MRI in acute ischemic stroke
NASA Astrophysics Data System (ADS)
Zhou, Iris Y.; Igarashi, Takahiro; Guo, Yingkun; Sun, Phillip Z.
2015-03-01
Amide proton transfer (APT) imaging is a specific form of chemical exchange saturation transfer (CEST) MRI that probes the pH-dependent amide proton exchange.The endogenous APT MRI is sensitive to tissue acidosis, which may complement the commonly used perfusion and diffusion scans for characterizing heterogeneous ischemic tissue damage. Whereas the saturation transfer asymmetry analysis (MTRasym) may reasonably compensate for direct RF saturation, in vivo MTRasym is however, susceptible to an intrinsically asymmetric shift (MTR'asym). Specifically, the reference scan for the endogenous APT MRI is 7 ppm upfield from that of the label scan, and subjects to concomitant RF irradiation effects, including nuclear overhauser effect (NOE)-mediated saturation transfer and semisolid macromolecular magnetization transfer. As such, the commonly used asymmetry analysis could not fully compensate for such slightly asymmetric concomitant RF irradiation effects, and MTRasym has to be delineated in order to properly characterize the pH-weighted APT MRI contrast. Given that there is very little change in relaxation time immediately after ischemia and the concomitant RF irradiation effects only minimally depends on pH, the APT contrast can be obtained as the difference of MTRasym between the normal and ischemic regions. Thereby, the endogenous amide proton concentration and exchange rate can be solved using a dual 2-pool model, and the in vivo MTR'asym can be calculated by subtracting the solved APT contrast from asymmetry analysis (i.e., MTR'asym =MTRasym-APTR). In addition, MTR'asym can be quantified using the classical 2-pool exchange model. In sum, our study delineated the conventional in vivo pH-sensitive MTRasym contrast so that pHspecific contrast can be obtained for imaging ischemic tissue acidosis.
Shi, Xin-Yu; Liu, Yao; Gu, Xian-Min; Hao, Sheng-Yu; Wang, Yu-Hong; Yan, Di; Jiang, Shu-Juang
2016-08-01
The serum (1 → 3)-β-D-glucan (BG) assay has been approved for diagnosing invasive fungal diseases (IFDs). However, the performance of (1 → 3)-β-D-glucan assay in bronchoalveolar lavage (BAL) fluid is various among studies. The present study aimed to assess the accuracy of (1 → 3)-β-D-glucan assay in bronchoalveolar lavage fluid for the diagnosis of invasive fungal diseases by means of meta-analysis and systematic review of relevant studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (OR) and a summary receiver-operating characteristic curve of BAL-BG for diagnosing invasive fungal diseases were pooled using meta-analysis. We also performed meta-regression analysis. A total of 838 patients (138 with proven or probable invasive fungal diseases), included in 6 studies, were analyzed. The pooled sensitivity, specificity, PLR, NLR and diagnostic odds ratio were 0.52 (95%CI, 0.38-0.53), 0.58 (95%CI, 0.55-0.61), 1.34 (95%CI, 1.08-1.66), 0.82 (95% CI, 0.63-1.07) and 1.71 (95%CI, 1.01-2.92) respectively. The area under the summary receiver operating characteristic curve, with 95% confidence intervals was 0.61 (95%CI, 0.67-0.55). The accuracy of (1 → 3)-β-D-glucan test in bronchoalveolar lavage fluid is marginal, so that the results should not be interpreted alone but can be used as a part of full assessment with clinical features, image findings and other laboratory results for the diagnosis of invasive fungal diseases. Copyright © 2016 Elsevier Ltd. All rights reserved.
Zhang, Xia; Zhou, Jian-Guo; Wu, Hua-Lian; Ma, Hu; Jiang, Zhi-Xia
2017-01-01
Background Anaplastic lymphoma kinase (ALK) gene fusion has been reported in 3∼5% non-small cell lung carcinoma (NSCLC) patients, and polymerase chain reaction (PCR) is commonly used to detecting the gene status, but the diagnostic capacity of it is still controversial. A systematic review and meta-analysis was conducted to clarify the diagnostic accuracy of PCR for detecting ALK gene rearrangement in NSCLC patients. Results 18 articles were enrolled, which included 21 studies, involving 2800 samples from NSCLC patients. The overall pooled parameters were calculated: sensitivity was 92.4% [95% confidence interval (CI): 82.2%–97.0%], specificity was 97.8% [95% CI: 95.1%–99.0%], PLR was 41.51 [95% CI: 18.10–95.22], NLR was 0.08 [95% CI: 0.03–0.19], DOR was 535.72 [95% CI: 128.48–2233.79], AUROC was 0.99 [95% CI: 0.98–1.00]. Materials and Methods Relevant articles were searched from PubMed, EMBASE, Web of Science, Cochrane library, American Society of Clinical Oncology (ASCO), European Society for Medical Oncology (ESMO), China National Knowledge Infrastructure (CNKI), China Wan Fang databases and Chinese biomedical literature database (CBM). Diagnostic capacity of PCR test was assessed by the pooled sensitivity and specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), area under the summary receiver operating characteristic (AUROC). Conclusions Based on the results from this review, PCR has good diagnostic performance for detecting the ALK gene fusion in NSCLC patients. Moreover, due to the poor methodology quality of the enrolled trials, more well-designed multi-center trials should be performed. PMID:29088875
Diagnosing malignant melanoma in ambulatory care: a systematic review of clinical prediction rules
Harrington, Emma; Clyne, Barbara; Wesseling, Nieneke; Sandhu, Harkiran; Armstrong, Laura; Bennett, Holly; Fahey, Tom
2017-01-01
Objectives Malignant melanoma has high morbidity and mortality rates. Early diagnosis improves prognosis. Clinical prediction rules (CPRs) can be used to stratify patients with symptoms of suspected malignant melanoma to improve early diagnosis. We conducted a systematic review of CPRs for melanoma diagnosis in ambulatory care. Design Systematic review. Data sources A comprehensive search of PubMed, EMBASE, PROSPERO, CINAHL, the Cochrane Library and SCOPUS was conducted in May 2015, using combinations of keywords and medical subject headings (MeSH) terms. Study selection and data extraction Studies deriving and validating, validating or assessing the impact of a CPR for predicting melanoma diagnosis in ambulatory care were included. Data extraction and methodological quality assessment were guided by the CHARMS checklist. Results From 16 334 studies reviewed, 51 were included, validating the performance of 24 unique CPRs. Three impact analysis studies were identified. Five studies were set in primary care. The most commonly evaluated CPRs were the ABCD, more than one or uneven distribution of Colour, or a large (greater than 6 mm) Diameter (ABCD) dermoscopy rule (at a cut-point of >4.75; 8 studies; pooled sensitivity 0.85, 95% CI 0.73 to 0.93, specificity 0.72, 95% CI 0.65 to 0.78) and the 7-point dermoscopy checklist (at a cut-point of ≥1 recommending ruling in melanoma; 11 studies; pooled sensitivity 0.77, 95% CI 0.61 to 0.88, specificity 0.80, 95% CI 0.59 to 0.92). The methodological quality of studies varied. Conclusions At their recommended cut-points, the ABCD dermoscopy rule is more useful for ruling out melanoma than the 7-point dermoscopy checklist. A focus on impact analysis will help translate melanoma risk prediction rules into useful tools for clinical practice. PMID:28264830
Sankaranarayanan, Rengaswamy; Shastri, Surendra S; Basu, Parthasarathi; Mahé, Cédric; Mandal, Ranajit; Amin, Geethanjali; Roy, Chinmayi; Muwonge, Richard; Goswami, Smriti; Das, Pradip; Chinoy, Roshini; Frappart, Lucien; Patil, Sharmila; Choudhury, Devjani; Mukherjee, Titha; Dinshaw, Ketayun
2004-01-01
Several studies have investigated the accuracy of naked eye visual inspection with acetic acid (VIA) in the early detection of cervical neoplasia. It is not clear whether low-level (2-4x) magnification (VIAM) can improve the sensitivity and specificity of VIA. The accuracy of both VIA and VIAM, provided by independent health workers, were evaluated in three cross-sectional studies involving 18,675 women aged 25-65 years in Kolkata and Mumbai in India. All screened women were investigated with colposcopy and biopsies were obtained based on colposcopy findings. The final disease status was based on the reference standard of histology (if biopsies had been taken) or colposcopy. Data from the studies were pooled to calculate the test characteristics for the detection of high-grade squamous intraepithelial lesions (HSIL). 14.1% and 14.2% were positive on testing with VIA and VIAM respectively. Two hundred twenty-nine were diagnosed with HSIL and 68 with invasive cancer. The pooled sensitivity, specificity, positive and negative predictive values for VIA in detecting high-grade squamous intraepithelial lesions (HSIL) were 60.3% (95% CI: 53.6-66.7), 86.8% (95% CI: 86.3-87.3), 5.9% (95% CI: 5.0-7.0), and 99.4% (95% CI: 99.2-99.5), respectively. The values were 64.2% (95% CI: 57.6-70.4), 86.8% (95% CI: 86.2-87.3), 6.3% (95% CI: 5.3-7.3) and 99.4% (95% CI: 99.3-99.6), respectively, for VIAM. Low-level magnification did not improve the test performance of naked eye visualization of acetic acid impregnated uterine cervix.
Bronchial lavage P 16INK4A gene promoter methylation and lung cancer diagnosis: A meta-analysis.
Yifan, D; Qun, L; Yingshuang, H; Xulin, L; Jianjun, W; Qian, M; Yuman, Yu; Zhaoyang, R
2015-12-01
To evaluate the diagnostic value of bronchial lavage P16INK4A promoter methylation and lung cancer. The databases of PubMed, Medline, China National Knowledge Infrastructure, and Wanfang were electronically searched by two reviewers to find the suitable studies related to the association between P16INK4A promoter methylation and lung cancer. The P16INK4A promoter methylation rate was extracted from each included individual study. The diagnostic sensitivity, specificity, and area under the receiver operating characteristic ROC curve of bronchial lavage P16INK4Aas a biomarker for diagnosis of lung cancer were pooled by stata 11.0 software (Stata Corporation, College Station, TX, USA). At last, 10 publications were included in this meta-analysis. Of the included 10 studies, five are published in English with relatively high quality and other five papers published in Chinese have relatively low quality. The pooled sensitivity and specificity of bronchial lavage P16INK4A promoter methylation for lung cancer diagnosis were 0.61 (95% confidence interval [CI]: 0.57-0.65) and 0.81 (95% CI: 0.78-0.85), respectively, with random effect model. The ROC curve were calculated and drawn according to Bayes' theorem by stata 11.0 software. The systematic area under the ROC was 0.72 (95% CI: 0.68-0.76), which indicated that the diagnostic value of bronchial lavage P16INK4A promoter methylation for lung cancer was relatively high. Moreover, no significant publication bias was existed in this meta-analysis (t = 0.69, P > 0.05). Bronchial lavage P16INK4A promoter methylation can be a potential biomarker for diagnosis of lung cancer.
Abbas, S M; Bissett, I P; Parry, B R
2007-04-01
Adhesions are the leading cause of small bowel obstruction. Identification of patients who require surgery is difficult. This review analyses the role of Gastrografin as a diagnostic and therapeutic agent in the management of adhesive small bowel obstruction. A systematic search of Medline, Embase and Cochrane databases was performed to identify studies of the use of Gastrografin in adhesive small bowel obstruction. Studies that addressed the diagnostic role of water-soluble contrast agent were appraised, and data presented as sensitivity, specificity, and positive and negative likelihood ratios. Results were pooled and a summary receiver-operator characteristic (ROC) curve was constructed. A meta-analysis of the data from six therapeutic studies was performed using the Mantel-Haenszel test and both fixed- and random-effect models. The appearance of water-soluble contrast agent in the colon on an abdominal radiograph within 24 h of its administration predicted resolution of obstruction with a pooled sensitivity of 97 per cent and specificity of 96 per cent. The area under the summary ROC curve was 0.98. Water-soluble contrast agent did not reduce the need for surgical intervention (odds ratio 0.81, P = 0.300), but it did reduce the length of hospital stay for patients who did not require surgery compared with placebo (weighted mean difference--1.84 days; P < 0.001). Published data strongly support the use of water-soluble contrast medium as a predictive test for non-operative resolution of adhesive small bowel obstruction. Although Gastrografin does not reduce the need for operation, it appears to shorten the hospital stay for those who do not require surgery.
Ma, Xiaowen; Wang, Le; Wu, Hao; Feng, Yuemin; Han, Xibiao; Bu, Haoran; Zhu, Qiang
2016-01-01
Liver stiffness (LS) and spleen stiffness (SS) are two most widely accessible non-invasive parameters for predicting esophageal varices (EV), but the reported accuracy of the two predictors have been inconsistent across studies. This meta-analysis aims to evaluate the diagnostic performance of LS and SS measurement for detecting EV in patients with chronic liver disease (CLD), and compare their accuracy. Pubmed/Medline, Embase, Cochrane Library and Ovid were searched for all studies assessing SS and LS simultaneously in EV diagnosis. A total of 16 studies including 1892 patients were included in this meta-analysis, and the pooled statistical parameters were calculated using the bivariate mixed effects models. In detection of any EV, for LS measurement, the summary sensitivity was 0.83 (95% confidence interval [CI]: 0.78-0.87), and the specificity was 0.66 (95% CI: 0.60-0.72). While for SS measurement, the pooled sensitivity and specificity was 0.88 (95% CI: 0.83-0.92) and 0.78 (95% CI: 0.73-0.83). The summary receiver operating characteristic (SROC) curve values of LS and SS were 0.81 (95% CI: 0.77-0.84) and 0.88 (95% CI: 0.85-0.91) respectively, and the results had statistical significance (P<0.01). The diagnostic odds ratio (DOR) of SS (25.73) was significantly higher than that of LS (9.54), with the relative DOR value was 2.48 (95%CI: 1.10-5.60), P<0.05. Under current techniques, SS is significantly superior to LS for identifying the presence of EV in patients with CLD. SS measurement may help to select patients for endoscopic screening.
Sevilla Berrios, Ronaldo A; O'Horo, John C; Velagapudi, Venu; Pulido, Juan N
2014-08-01
The prognostic implications of myocardial dysfunction in patients with sepsis and its association with mortality are controversial. Several tools have been proposed to evaluate cardiac function in these patients, but their usefulness beyond guiding therapy is unclear. We review the value of echocardiographic estimate of left ventricular ejection fraction (LVEF) in the setting of severe sepsis and/or septic shock and its correlation with 30-day mortality. We conducted a systematic review and meta-analysis to evaluate the prognostic functionality of newly diagnosed LV systolic dysfunction by transthoracic echocardiography on critical ill patients admitted to the intensive care unit with severe sepsis or septic shock. A search of EMBASE and PubMed, Ovide MEDLINE, and Cochrane CENTRAL medical databases yielded 7 studies meeting inclusion criteria reporting on a total of 585 patients. The pooled sensitivity of depressed LVEF for mortality was 52% (95% confidence interval [CI], 29%-73%), and pooled specificity was 63% (95% CI, 53%-71%). Summary receiver operating characteristic curve showed an area under the curve of 0.62 (95% CI, 0.58-0.67). The overall mortality diagnostic odd ratio for septic patients with LV systolic dysfunction was 1.92 (95% CI, 1.27-2.899). Statistical heterogeneity of studies was moderate. The presence of new LV systolic dysfunction associated with sepsis and defined as low LVEF is neither a sensitive nor a specific predictor of mortality. These findings are limited because of the heterogeneity and underpower of the studies. Further research into this method is warranted. Copyright © 2014 Elsevier Inc. All rights reserved.
Zheng, Zhongjun; Jiang, Libing; Ye, Ligang; Gao, Yuzhi; Tang, Luping; Zhang, Mao
2015-12-01
Sepsis is a common condition that has a high mortality and morbidity that need prompt diagnosis and treatment. Biomarkers like Soluble CD14 subtype (sCD14-ST, presepsin) may be useful in identifying patients with sepsis and its diagnostic superiority has been confirmed by several preliminary studies. The aim of this study was systematically and quantitatively to evaluate the value of presepsin for the diagnosis of sepsis through the method of meta-analysis. Four major databases, including MEDLINE, EMBASE, ISI Web of Knowledge, and the Cochrane Library were systematically searched from inception to March 2015. Two investigators conducted the processes of literature search, study selection, data extraction, and quality evaluation independently. And the original data were extracted from all eligible individual studies to construct two-by-two tables. A total of eight studies comprising 1757 patients were included in this meta-analysis. The pooled sensitivity, specificity, and diagnostic odds ratio were 0.77 (95 % confidence interval [CI]: 0.75-0.80), 0.73 (95 % CI 0.69-0.77), and 14.25 (95 % CI 8.66-23.42), respectively. The summary receiver operating characteristic curve (SROC) area under the curve (AUC) was 0.8598. The subgroup analysis based on excluding the outliers showed that the pooled sensitivity and specificity were 0.85 (95 % CI 0.81-0.89) and 0.65 (95 % CI 0.59-0.70), respectively. The AUC was 0.8213 with no significant heterogeneity. Presepsin has moderate diagnostic capacity for the detection of sepsis. Further research of presepsin is needed before widespread use in emergency department. And presepsin in combination with other laboratory biomarkers in diagnosing sepsis may be the focus of future studies.
Chen, Yile; Tai, Qiang; Hong, Shaodong; Kong, Yuan; Shang, Yushu; Liang, Wenhua; Guo, Zhiyong; He, Xiaoshun
2012-11-15
The question of whether high pretransplantation soluble CD30 (sCD30) level can be a predictor of kidney transplant acute rejection (AR) is under debate. Herein, we performed a meta-analysis on the predictive efficacy of sCD30 for AR in renal transplantation. PubMed (1966-2012), EMBASE (1988-2012), and Web of Science (1986-2012) databases were searched for studies concerning the predictive efficacy of sCD30 for AR after kidney transplantation. After a careful review of eligible studies, sensitivity, specificity, and other measures of the accuracy of sCD30 were pooled. A summary receiver operating characteristic curve was used to represent the overall test performance. Twelve studies enrolling 2507 patients met the inclusion criteria. The pooled estimates for pretransplantation sCD30 in prediction of allograft rejection risk were poor, with a sensitivity of 0.70 (95% confidence interval (CI), 0.66-0.74), a specificity of 0.48 (95% CI, 0.46-0.50), a positive likelihood ratio of 1.35 (95% CI, 1.20-1.53), a negative likelihood ratio of 0.68 (95% CI, 0.55-0.84), and a diagnostic odds ratio of 2.07 (95% CI, 1.54-2.80). The area under curve of the summary receiver operating characteristic curve was 0.60, indicating poor overall accuracy of the serum sCD30 level in the prediction of patients at risk for AR. The results of the meta-analysis show that the accuracy of pretransplantation sCD30 for predicting posttransplantation AR was poor. Prospective studies are needed to clarify the usefulness of this test for identifying risks of AR in transplant recipients.
Shi, Hong-Bin; Yu, Jia-Xing; Yu, Jian-Xiu; Feng, Zheng; Zhang, Chao; Li, Guang-Yong; Zhao, Rui-Ning; Yang, Xiao-Bo
2017-08-03
Previous studies have revealed the importance of microRNAs' (miRNAs) function as biomarkers in diagnosing human bladder cancer (BC). However, the results are discordant. Consequently, the possibility of miRNAs to be BC biomarkers was summarized in this meta-analysis. In this study, the relevant articles were systematically searched from CBM, PubMed, EMBASE, and Chinese National Knowledge Infrastructure (CNKI). The bivariate model was used to calculate the pooled diagnostic parameters and summary receiver operator characteristic (SROC) curve in this meta-analysis, thereby estimating the whole predictive performance. STATA software was used during the whole analysis. Thirty-one studies from 10 articles, including 1556 cases and 1347 controls, were explored in this meta-analysis. In short, the pooled sensitivity, area under the SROC curve, specificity, positive likelihood ratio, diagnostic odds ratio, and negative likelihood ratio were 0.72 (95%CI 0.66-0.76), 0.80 (0.77-0.84), 0.76 (0.71-0.81), 3.0 (2.4-3.8), 8 (5.0-12.0), and 0.37 (0.30-0.46) respectively. Additionally, sub-group and meta-regression analyses revealed that there were significant differences between ethnicity, miRNA profiling, and specimen sub-groups. These results suggested that Asian population-based studies, multiple-miRNA profiling, and blood-based assays might yield a higher diagnostic accuracy than their counterparts. This meta-analysis demonstrated that miRNAs, particularly multiple miRNAs in the blood, might be novel, useful biomarkers with relatively high sensitivity and specificity and can be used for the diagnosis of BC. However, further prospective studies with more samples should be performed for further validation.
Pan, Xiaoyu; Chen, Jiechun; Wang, Weijie; Chen, Ling; Wang, Lin; Ma, Quan; Zhang, Jianbo; Chen, Lichao; Wang, Gang; Zhang, Meixi; Wu, Hao; Cheng, Ruochuan
2017-02-07
Resveratrol has been widely investigated for its potential health properties, although little is known about its mechanism in vivo. Previous studies have indicated that resveratrol produces antinociceptive effects in mice. Calcium channels and calcium/caffeine-sensitive pools are reported to be associated with analgesic effect. The present study was to explore the involvement of Ca2+ channel and calcium/caffeine-sensitive pools in the antinociceptive response of resveratrol. Tail-flick test was used to assess antinociception in mice treated with resveratrol or the combinations of resveratrol with MK 801, nimodipine, CaCl2, ryanodine and ethylene glycol tetraacetic acid (EGTA), respectively. The Ca2+/calmodulin-dependent protein kinase II (CaMKII) and brain-derived neurotrophic factor (BDNF) levels in the spinal cord were also investigated when treated with the above drugs. The results showed that resveratrol increased the tail flick latency in the tail-flick test, in dose-dependent manner. N-methyl-D-aspartate (NMDA) glutamate receptor antagonist MK 801 potentiated the antinociceptive effects of sub-threshold dose of resveratrol at 10 mg/kg. Ca2+ channel blocker, however, abolished the antinociceptive effects of resveratrol. In contrast to these results, EGTA or ryanodine treatment (i.c.v.) potentiated resveratrol-induced antinociception. There was a significant decrease in p-CaMKII and an increase in BDNF expression in the spinal cord when combined with MK 801, nimodipine, ryanodine and EGTA. While an increase in p-CaMKII level and a decrease in BDNF expression were observed when high dose of resveratrol combined with CaCl2. These findings suggest that resveratrol exhibits the antinociceptive effects by inhibition of calcium channels and calcium/caffeine-sensitive pools.
Lei, Jinghui; Li, Yafeng; Zhang, Suli; Wu, Ye; Wang, Pengli; Liu, Huirong
2016-01-01
Abstract Angiotensin II type 1 receptor autoantibody (AT1-AA) is found in patients with non-gravid hypertension or pre-eclampsia, but the relationship is uncertain. The aim of the present study was to assess the association between AT1-AA and high blood pressure using meta-analysis, and to evaluate the prognosis value of AT1-AA for hypertensive diseases. Literature search from PubMed, Embase, and Cochrane databases were conducted using keywords “hypertension” or “pre-eclampsia,” “angiotensin II receptor type 1 autoantibody,” and its aliases from April 1999 to December 2015. Studies evaluating the association between AT1-AA and non-gravid hypertension or pre-eclampsia were included in this analysis. The quality of the eligible studies was assessed based on the Newcastle–Ottawa Scale with some modifications. Two researchers then independently reviewed all included studies and extracted all relevant data. Association between AT1-AA and hypertension was tested with pooled odds ratios (ORs) and 95% confidence intervals (CIs). Finally, we evaluated whether AT1-AA predicted the prognosis of hypertension by using a summary receiver-operating characteristic (ROC) curve and sensitivity analysis. Ten studies were finally included in this meta-analysis. AT1-AA showed more significant association with pre-eclampsia than that with non-gravid hypertension (pooled OR 32.84, 95% CI 17.19–62.74; and pooled OR 4.18, 95% CI 2.20–7.98, respectively). Heterogeneity among studies was also detected probably due to different hypertensive subtypes and AT1-AA measuring methods. Area under summary ROC curve (AUC) of pre-eclampsia was 0.92 (sensitivity 0.76; specificity 0.86). Area under the ROC curve of overall hypertensive diseases or non-gravid hypertension was lower than that of pre-eclampsia (0.86 and 0.72, respectively) with lower sensitivities (0.46 and 0.26, respectively). The major limitation of this analysis was the publication bias due to lack of unpublished data and the language limitation during literature search. Prospective study with large simple size and specific measuring data collection are needed to enhance our findings in the future. Our analysis confirms that elevated AT1-AA in serum is significantly associated with hypertensive disorder, especially pre-eclampsia. AT1-AA may be a valuable indicator for poorer prognosis of patients with pre-eclampsia, and could be used in patients with hypertensive disease for risk evaluation and making individual treatment decision. PMID:27124051
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-26
... Catch Entitlements: Updated Annual Catch Limits for Sectors and the Common Pool for Fishing Year 2010... fishing year (FY) 2010 specification of annual catch limits (ACLs) for common pool vessels (common pool... fish in the common pool for FY 2010. DATES: Effective May 21, 2010 through April 30, 2011. FOR FURTHER...
NASA Astrophysics Data System (ADS)
Tulina, A. S.; Semenov, V. M.
2015-08-01
The sensitivity of the potentially mineralizable pool of soil organic matter (Cpm) to changes in temperature and moisture has been assessed from the temperature coefficient ( Q10) and the moisture coefficient ( W 10), which indicate how much the Cpm size changes, when the temperature changes by 10°C and the soil water content changes by 10 wt %, respectively. Samples of gray forest soil, podzolized chernozem, and dark chestnut soil taken from arable plots have been incubated at 8, 18, and 28°C and humidity of 10, 25, and 40 wt %. From the data on the production of C-CO2 by soil samples during incubation for 150 days, the content of Cpm has been calculated. It has been shown that, on average for the three soils, an increase in temperature accounts for 63% of the rise in the pool of potentially mineralizable organic matter, whereas an increase in moisture accounts for 8% of that rise. The temperature coefficients of the potentially mineralizable pool are 2.71 ± 0.64, 1.27 ± 0.20, and 1.85 ± 0.30 in ranges of 8-18, 18-28, and 8-28°C, respectively; the moisture coefficients are 1.19 ± 0.11, 1.09 ± 0.05, and 1.14 ± 0.06 in ranges of 10-25, 25-40, and 10-40 wt %, respectively. The easily mineralizable fraction (C1, k 1 > 0.1 days-1) of the active pool of soil organic matter is less sensitive to temperature than the hardly mineralizable fraction (C3, 0.01 > k 3 > 0.001 days-1); their Q 10 values are 0.91 ± 0.15 and 2.40 ± 0.31, respectively. On the contrary, the easily mineralizable fraction is more sensitive to moistening than the hardly mineralizable fraction: their W 10 values are 1.22 ± 0.06 and 1.03 ± 0.08, respectively. The intensification of mineralization with rising temperature and water content during a long-term incubation results in the exhausting of the active pool, which reduces the production of CO2 by the soils during the repeated incubation under similar conditions nonlimiting mineralization.
Verdugo, Cristobal; Jones, Geoff; Johnson, Wes; Wilson, Peter; Stringer, Lesley; Heuer, Cord
2014-12-01
The study aimed to estimate the national- and island-level flock/herd true prevalence (HTP) of Mycobacterium avium subsp. paratuberculosis (MAP) infection in pastoral farmed sheep, beef cattle and deer in New Zealand. A random sample of 238 single- or multi-species farms was selected from a postal surveyed population of 1940 farms. The sample included 162 sheep flocks, 116 beef cattle and 99 deer herds from seven of 16 geographical regions. Twenty animals from each species present on farm were randomly selected for blood and faecal sampling. Pooled faecal culture testing was conducted using a single pool (sheep flocks) or two pools (beef cattle/deer herds) of 20 and 10 samples per pool, respectively. To increase flock/herd-level sensitivity, sera from all 20 animals from culture negative flocks/herds were individually tested by Pourquier(®) ELISA (sheep and cattle) or Paralisa™ (deer). Results were adjusted for sensitivity and specificity of diagnostic tests using a novel Bayesian latent class model. Outcomes were adjusted by their sampling fractions to obtain HTP estimates at national level. For each species, the posterior probability (POPR) of HTP differences between New Zealand North (NI) and South (SI) Islands was obtained. Across all species, 69% of farms had at least one species test positive. Sheep flocks had the highest HTP estimate (76%, posterior probability interval (PPI) 70-81%), followed by deer (46%, PPI 38-55%) and beef herds (42%, PPI 35-50%). Differences were observed between the two main islands of New Zealand, with higher HTP in sheep and beef cattle flocks/herds in the NI. Sheep flock HTP was 80% in the NI compared with 70% (POPR=0.96) in the SI, while the HTP for beef cattle was 44% in the NI and 38% in the SI (POPR=0.80). Conversely, deer HTP was higher in the SI (54%) than the NI (33%, POPR=0.99). Infection with MAP is endemic at high prevalence in sheep, beef cattle and deer flocks/herds across New Zealand. Copyright © 2014 Elsevier B.V. All rights reserved.
Reliability and validity of the work and social adjustment scale in phobic disorders.
Mataix-Cols, David; Cowley, Amy J; Hankins, Matthew; Schneider, Andreas; Bachofen, Martin; Kenwright, Mark; Gega, Lina; Cameron, Rachel; Marks, Isaac M
2005-01-01
The Work and Social Adjustment Scale (WSAS) is a simple widely used 5-item measure of disability whose psychometric properties need more analysis in phobic disorders. The reliability, factor structure, validity, and sensitivity to change of the WSAS were studied in 205 phobic patients (73 agoraphobia, 62 social phobia, and 70 specific phobia) who participated in various open and randomized trials of self-exposure therapy. Internal consistency of the WSAS was excellent in all phobics pooled and in agoraphobics and social phobics separately. Principal components analysis extracted a single general factor of disability. Specific phobics gave less consistent ratings across WSAS items, suggesting that some items were less relevant to their problem. Internal consistency was marginally higher for self-ratings than clinician ratings of the WSAS. Self-ratings and clinician ratings correlated highly though patients tended to rate themselves as more disabled than clinicians did. WSAS total scores reflected differences in phobic severity and improvement with treatment. The WSAS is a valid, reliable, and change-sensitive measure of work/social and other adjustment in phobic disorders, especially in agoraphobia and social phobia.
Detection of coins ingested by children using a handheld metal detector: a systematic review.
Lee, J B; Ahmad, S; Gale, C P
2005-12-01
To determine if the use of a handheld metal detector (HHMD) can safely reduce the number of radiographs requested in cases of coins ingested by children, a search was performed to identify prospective studies of the ability of an HHMD to identify the presence or absence of ingested coin in children (17 years or younger). Outcome measures were presence or absence of coin on metal detector screening, and accuracy of coin localisation. Inclusion and exclusion criteria were defined. Mantel-Haenszel (fixed effect model) pooling with 95% confidence intervals (CI) was used to calculate overall sensitivities and specificities. In total, 11 studies met the inclusion criteria. The overall sensitivity of the HHMD at detecting the presence of coins was 99.4% (95% CI 98.0 to 99.9%) and accuracy at localisation was 99.8% (98.5 to 100.0%). The overall specificity of the HHMD was 100% (76.8 to 100%). Use of the HHMD is an accurate, radiation free, and cost effective method of identifying and localising coins ingested by children. An algorithm for investigating children with coin ingestion is proposed.
Tomé, Angelo R; Castro, Enrique; Santos, Rosa M; Rosário, Luís M
2007-06-20
2-Methylthioadenosine 5'-triphosphate (2-MeSATP), formerly regarded as a specific P2Y (metabotropic) purinergic receptor agonist, stimulates Ca2+ influx and evokes catecholamine release from adrenal chromaffin cells. These cells express P2Y and P2X (ionotropic) purinoceptors, with the latter providing an important Ca2+ influx pathway. Using single cell calcium imaging techniques, we have determined whether 2-MeSATP might be a specific P2X receptor agonist in bovine chromaffin cells and assessed the relative role of P2X and P2Y receptors on catecholamine secretion from these cells. ATP raised the [Ca2+]i in ~50% of the cells. Removing extracellular Ca2+ suppressed the [Ca2+]i-raising ability of 2-MeSATP, observed in ~40% of the ATP-sensitive cells. This indicates that 2-MeSATP behaves as a specific ionotropic purinoceptor agonist in bovine chromaffin cells. The 2-MeSATP-induced [Ca2+]i-rises were suppressed by PPADS. UTP raised the [Ca2+]i in ~40% of the ATP-sensitive cells, indicating that these expressed Ca2+-mobilizing P2Y receptors. UTP-sensitive receptors may not be the only P2Y receptors present, as suggested by the observation that ~20% of the ATP-sensitive pool did not respond to either 2-MeSATP or UTP. The average sizes of the ATP- and 2-MeSATP-evoked [Ca2+]i responses were identical in UTP-insensitive cells. 2-MeSATP stimulated Ca2+ influx and evoked catecholamine release, whereas UTP elicited Ca2+ release from intracellular stores but did not evoke secretion. 2-MeSATP-induced secretion was strongly inhibited by Cd2+ and suppressed by extracellular Ca2+ or Na+ removal. TTX inhibited 2-MeSATP-evoked secretion by ~20%. 2-MeSATP is a specific P2X purinoceptor agonist and a potent secretagogue in bovine chromaffin cells. Activation of 2-MeSATP-sensitive receptors stimulates Ca2+ influx mainly via voltage-sensitive Ca2+ channels. For the most part, these are activated by the depolarization brought about by Na+ influx across P2X receptor pores.
GenoType® Mtbdrsl assay for resistance to second-line anti-tuberculosis drugs
Theron, Grant; Peter, Jonny; Richardson, Marty; Warren, Rob; Dheda, Keertan; Steingart, Karen R
2016-01-01
Background Genotype® MTBDRsl (MTBDRsl) is a rapid DNA-based test for detecting specific mutations associated with resistance to fluoroquinolones and second-line injectable drugs (SLIDs) in Mycobacterium tuberculosis complex. MTBDRsl version 2.0 (released in 2015) identifies the mutations detected by version 1.0, as well as additional mutations. The test may be performed on a culture isolate or a patient specimen, which eliminates delays associated with culture. Version 1.0 requires a smear-positive specimen, while version 2.0 may use a smear-positive or -negative specimen. We performed this updated review as part of a World Health Organization process to develop updated guidelines for using MTBDRsl. Objectives To assess and compare the diagnostic accuracy of MTBDRsl for: 1. fluoroquinolone resistance, 2. SLID resistance, and 3. extensively drug-resistant tuberculosis, indirectly on a M. tuberculosis isolate grown from culture or directly on a patient specimen. Participants were people with rifampicin-resistant or multidrug-resistant tuberculosis. The role of MTBDRsl would be as the initial test, replacing culture-based drug susceptibility testing (DST), for detecting second-line drug resistance. Search methods We searched the following databases without language restrictions up to 21 September 2015: the Cochrane Infectious Diseases Group Specialized Register; MEDLINE; Embase OVID; Science Citation Index Expanded, Conference Proceedings Citation Index-Science, and BIOSIS Previews (all three from Web of Science); LILACS; and SCOPUS; registers for ongoing trials; and ProQuest Dissertations & Theses A&I. We reviewed references from included studies and contacted specialists in the field. Selection criteria We included cross-sectional and case-control studies that determined MTBDRsl accuracy against a defined reference standard (culture-based DST, genetic sequencing, or both). Data collection and analysis Two review authors independently extracted data and assessed quality using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. We synthesized data for versions 1.0 and 2.0 separately. We estimated MTBDRsl sensitivity and specificity for fluoroquinolone resistance, SLID resistance, and extensively drug-resistant tuberculosis when the test was performed indirectly or directly (smear-positive specimen for version 1.0, smear-positive or -negative specimen for version 2.0). We explored the influence on accuracy estimates of individual drugs within a drug class and of different reference standards. We performed most analyses using a bivariate random-effects model with culture-based DST as reference standard. Main results We included 27 studies. Twenty-six studies evaluated version 1.0, and one study version 2.0. Of 26 studies stating specimen country origin, 15 studies (58%) evaluated patients from low- or middle-income countries. Overall, we considered the studies to be of high methodological quality. However, only three studies (11%) had low risk of bias for the reference standard; these studies used World Health Organization (WHO)-recommended critical concentrations for all drugs in the culture-based DST reference standard. MTBDRsl version 1.0 Fluoroquinolone resistance: indirect testing, MTBDRsl pooled sensitivity and specificity (95% confidence interval (CI)) were 85.6% (79.2% to 90.4%) and 98.5% (95.7% to 99.5%), (19 studies, 2223 participants); direct testing (smear-positive specimen), pooled sensitivity and specificity were 86.2% (74.6% to 93.0%) and 98.6% (96.9% to 99.4%), (nine studies, 1771 participants, moderate quality evidence). SLID resistance: indirect testing, MTBDRsl pooled sensitivity and specificity were 76.5% (63.3% to 86.0%) and 99.1% (97.3% to 99.7%), (16 studies, 1921 participants); direct testing (smear-positive specimen), pooled sensitivity and specificity were 87.0% (38.1% to 98.6%) and 99.5% (93.6% to 100.0%), (eight studies, 1639 participants, low quality evidence). Extensively drug-resistant tuberculosis: indirect testing, MTBDRsl pooled sensitivity and specificity were 70.9% (42.9% to 88.8%) and 98.8% (96.1% to 99.6%), (eight studies, 880 participants); direct testing (smear-positive specimen), pooled sensitivity and specificity were 69.4% (38.8% to 89.0%) and 99.4% (95.0% to 99.3%), (six studies, 1420 participants, low quality evidence). Similar to the original Cochrane review, we found no evidence of a significant difference in MTBDRsl version 1.0 accuracy between indirect and direct testing for fluoroquinolone resistance, SLID resistance, and extensively drug-resistant tuberculosis. MTBDRsl version 2.0 Fluoroquinolone resistance: direct testing, MTBDRsl sensitivity and specificity were 97% (83% to 100%) and 98% (93% to 100%), smear-positive specimen; 80% (28% to 99%) and 100% (40% to 100%), smear-negative specimen. SLID resistance: direct testing, MTBDRsl sensitivity and specificity were 89% (72% to 98%) and 90% (84% to 95%), smear-positive specimen; 80% (28% to 99%) and 100% (40% to 100%), smear-negative specimen. Extensively drug-resistant tuberculosis: direct testing, MTBDRsl sensitivity and specificity were 79% (49% to 95%) and 97% (93% to 99%), smear-positive specimen; 50% (1% to 99%) and 100% (59% to 100%), smear-negative specimen. We had insufficient data to estimate summary sensitivity and specificity of version 2.0 (smear-positive and -negative specimens) or to compare accuracy of the two versions. A limitation was that most included studies did not consistently use the World Health Organization (WHO)-recommended concentrations for drugs in the culture-based DST reference standard. Authors' conclusions In people with rifampicin-resistant or multidrug-resistant tuberculosis, MTBDRsl performed on a culture isolate or smear-positive specimen may be useful in detecting second-line drug resistance. MTBDRsl (smear-positive specimen) correctly classified around six in seven people as having fluoroquinolone or SLID resistance, although the sensitivity estimates for SLID resistance varied. The test rarely gave a positive result for people without drug resistance. However, when second-line drug resistance is not detected (MTBDRsl result is negative), conventional DST can still be used to evaluate patients for resistance to the fluoroquinolones or SLIDs. We recommend that future work evaluate MTBDRsl version 2.0, in particular on smear-negative specimens and in different settings to account for different resistance-causing mutations that may vary by strain. Researchers should also consider incorporating WHO-recommended critical concentrations into their culture-based reference standards. PLAIN LANGUAGE SUMMARY The rapid test GenoType® MTBDRsl for testing resistance to second-line TB drugs Background Different drugs are available to treat tuberculosis (TB), but resistance to these drugs is a growing problem. People with drug-resistant TB require second-line TB drugs that, compared with first-line TB drugs, must be taken for longer and may be associated with more harms. Detecting TB drug resistance quickly is important for improving health, reducing deaths, and decreasing the spread of drug-resistant TB. Definitions Multidrug-resistant TB (MDR-TB) is caused by TB bacteria that are resistant to at least isoniazid and rifampicin, the two most potent TB drugs. Extensively drug-resistant TB (XDR-TB) is a type of MDR-TB that is resistant to nearly all TB drugs. What test is evaluated by this review? GenoType® MTBDRsl (MTBDRsl) is a rapid test for detecting resistance to second-line TB drugs. In people with MDR-TB, MTBDRsl is used to detect additional drug resistance. The test may be performed on TB bacteria grown in culture from a patient specimen (indirect testing) or on a patient specimen (direct testing), which eliminates delays associated with culture. MTBDRsl version 1.0 requires a specimen to be smear-positive by microscopy, while version 2.0 (released in 2015) may use a smear-positive or -negative specimen. What are the aims of the review? We wanted to find out how accurate MTBDRsl is for detecting drug resistance; to compare indirect and direct testing; and to compare the two test versions. How up-to-date is the review? We searched for and used studies that had been published up to 21 September 2015. What are the main results of the review? We found 27 studies; 26 studies evaluated MTBDRsl version 1.0 and one study evaluated version 2.0. Fluoroquinolone drugs MTBDRsl version 1.0 (smear-positive specimen) detected 86% of people with fluoroquinolone resistance and rarely gave a positive result for people without resistance (GRADE, moderate quality evidence). Second-line injectable drugs MTBDRsl version 1.0 (smear-positive specimen) detected 87% of people with second-line injectable drug resistance and rarely gave a positive result for people without resistance (GRADE, low quality evidence). XDR-TB MTBDRsl version 1.0 (smear-positive specimen) detected 69% of people with XDR-TB and rarely gave a positive result for people without resistance (GRADE, low quality evidence). For MTBDRsl version 1.0, we found similar results for indirect and direct testing (smear-positive specimen). As we identified only one study evaluating MTBDRsl version 2.0, we could not be sure of the diagnostic accuracy of version 2.0. Also, we could not compare accuracy of the two versions. What is the methodological quality of the evidence? We used the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool to assess study quality. Overall, we considered the included studies to be of high quality; however, we had concerns about how the reference standard (the benchmark against which MTBDRsl was measured) was applied. What are the authors' conclusions? MTBDRsl (smear-positive specimen) identified most of the patients with second-line drug resistance. When the test reports a negative result, conventional testing for drug resistance can still be used. PMID:27605387
Alcázar, Juan Luis; Gastón, Begoña; Navarro, Beatriz; Salas, Rocío; Aranda, Juana; Guerriero, Stefano
2017-11-01
To compare the diagnostic accuracy of transvaginal ultrasound (TVS) and magnetic resonance imaging (MRI) for detecting myometrial infiltration (MI) in endometrial carcinoma. An extensive search of papers comparing TVS and MRI in assessing MI in endometrial cancer was performed in MEDLINE (PubMed), Web of Science, and Cochrane Database from January 1989 to January 2017. Quality was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Our extended search identified 747 citations but after exclusions we finally included in the meta-analysis 8 articles. The risk of bias for most studies was low for most 4 domains assessed in QUADAS-2. Overall, pooled estimated sensitivity and specificity for diagnosing deep MI were 75% (95% confidence interval [CI]=67%-82%) and 82% (95% CI=75%-93%) for TVS, and 83% (95% CI=76%-89%) and 82% (95% CI=72%-89%) for MRI, respectively. No statistical differences were found when comparing both methods (p=0.314). Heterogeneity was low for sensitivity and high for specificity for TVS and MRI. MRI showed a better sensitivity than TVS for detecting deep MI in women with endometrial cancer. However, the difference observed was not statistically significant. Copyright © 2017. Asian Society of Gynecologic Oncology, Korean Society of Gynecologic Oncology
2017-01-01
Objective To compare the diagnostic accuracy of transvaginal ultrasound (TVS) and magnetic resonance imaging (MRI) for detecting myometrial infiltration (MI) in endometrial carcinoma. Methods An extensive search of papers comparing TVS and MRI in assessing MI in endometrial cancer was performed in MEDLINE (PubMed), Web of Science, and Cochrane Database from January 1989 to January 2017. Quality was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Results Our extended search identified 747 citations but after exclusions we finally included in the meta-analysis 8 articles. The risk of bias for most studies was low for most 4 domains assessed in QUADAS-2. Overall, pooled estimated sensitivity and specificity for diagnosing deep MI were 75% (95% confidence interval [CI]=67%–82%) and 82% (95% CI=75%–93%) for TVS, and 83% (95% CI=76%–89%) and 82% (95% CI=72%–89%) for MRI, respectively. No statistical differences were found when comparing both methods (p=0.314). Heterogeneity was low for sensitivity and high for specificity for TVS and MRI. Conclusion MRI showed a better sensitivity than TVS for detecting deep MI in women with endometrial cancer. However, the difference observed was not statistically significant. PMID:29027404
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nielsen, Yousef W., E-mail: yujwni01@heh.regionh.d; Eiberg, Jonas P.; Logager, Vibeke B.
The purpose of this investigation was to determine if addition of infragenicular steady-state (SS) magnetic resonance angiography (MRA) to first-pass imaging improves diagnostic performance compared with first-pass imaging alone in patients with peripheral arterial disease (PAD) undergoing whole-body (WB) MRA. Twenty consecutive patients with PAD referred to digital-subtraction angiography (DSA) underwent WB-MRA. Using a bolus-chase technique, first-pass WB-MRA was performed from the supra-aortic vessels to the ankles. The blood-pool contrast agent gadofosveset trisodium was used at a dose of 0.03 mmol/kg body weight. Ten minutes after injection of the contrast agent, high-resolution (0.7-mm isotropic voxels) SS-MRA of the infragenicular arteriesmore » was performed. Using DSA as the 'gold standard,' sensitivities and specificities for detecting significant arterial stenoses ({>=}50% luminal narrowing) with first-pass WB-MRA, SS-MRA, and combined first-pass and SS-MRA were calculated. Kappa statistics were used to determine intermodality agreement between MRA and DSA. Overall sensitivity and specificity for detecting significant arterial stenoses with first-pass WB-MRA was 0.70 (95% confidence interval 0.61 to 0.78) and 0.97 (0.94 to 0.99), respectively. In first-pass WB-MRA, the lowest sensitivity was in the infragenicular region, with a value of 0.42 (0.23 to 0.63). Combined analysis of first-pass WB-MRA and SS-MRA increased sensitivity to 0.81 (0.60 to 0.93) in the infragenicular region, with specificity of 0.94 (0.88 to 0.97). Sensitivity and specificity for detecting significant arterial stenoses with isolated infragenicular SS-MRA was 0.47 (0.27 to 0.69) and 0.86 (0.78 to 0.91), respectively. Intermodality agreement between MRA and DSA in the infragenicular region was moderate for first-pass WB-MRA ({kappa} = 0.49), fair for SS-MRA ({kappa} = 0.31), and good for combined first-pass/SS-MRA ({kappa} = 0.71). Addition of infragenicular SS-MRA to first-pass WB MRA improves diagnostic performance.« less
Liu, Jie; Silapong, Sasikorn; Jeanwattanalert, Pimmada; Lertsehtakarn, Paphavee; Bodhidatta, Ladaporn; Swierczewski, Brett; Mason, Carl; McVeigh, Annette L; Savarino, Stephen J; Nshama, Rosemary; Mduma, Esto; Maro, Athanasia; Zhang, Jixian; Gratz, Jean; Houpt, Eric R
2017-01-01
Enterotoxigenic Escherichia coli (ETEC) is a leading cause of childhood diarrhea in low income countries and in travelers to those areas. Inactivated enterotoxins and colonization factors (CFs) are leading vaccine candidates, therefore it is important to determine the prevailing CF types in different geographic locations and populations. Here we developed real time PCR (qPCR) assays for 14 colonization factors, including the common vaccine targets. These assays, along with three enterotoxin targets (STh, STp, and LT) were formulated into three 5-plex qPCR panels, and validated on 120 ETEC isolates and 74 E. coli colony pools. The overall sensitivity and specificity was 99% (199/202) and 99% (2497/2514), respectively, compared to the CF results obtained with conventional PCR. Amplicon sequencing of discrepant samples revealed that the qPCR was 100% accurate. qPCR panels were also performed on nucleic acid extracted from stool and compared to the results of the ETEC isolates or E. coli colony pools cultured from them. 95% (105/110) of the CF detections in the cultures were confirmed in the stool. Additionally, direct testing of stool yielded 30 more CF detections. Among 74 randomly selected E. coli colony pools with paired stool, at least one CF was detected in 63% (32/51) of the colony pools while at least one CF was detected in 78% (47/60) of the stool samples (P = NS). We conclude that these ETEC CF assays can be used on both cultures and stool samples to facilitate better understanding of CF distribution for ETEC epidemiology and vaccine development.
Augustin, Jean-Christophe; Kalmokoff, Martin; Ells, Timothy; Favret, Sandra; Desreumaux, Jennifer; Decourseulles Brasseur, Emilie; Gnanou Besse, Nathalie
2016-12-01
A stochastic model describing the growth of Listeria monocytogenes during enrichment in half Fraser was developed for the purpose of estimating the effects of modifications to the first enrichment step of the EN ISO 11290-1 detection method. Information pertaining to the variability of growth rates, physiological state of the cell, and the behavior of individual cells contaminating the food were obtained from previously published studies. We used this model to investigate the impact of pooling enrichment broths (wet pooling) on the performance of the standard method. For validation of the model, the numbers of L. monocytogenes occurring in 88 naturally contaminated foods following pre-enrichment were compared to model-simulated microbial counts. The model was then used to perform simulations representative of the natural contamination observed for smoked salmon in the European baseline survey of 2010-2011. The model-estimated L. monocytogenes levels following individual enrichment or following the pooling of five broths where only one would be contaminated were compared. The model indicated a 10% loss of method sensitivity resulting from wet pooling. The model also predicted a 5% decrease in the sensitivity of the method when the duration of the enrichment was reduced from 24 to 22 h. Copyright © 2016 Elsevier Ltd. All rights reserved.
Arbyn, Marc; Verdoodt, Freija; Snijders, Peter J F; Verhoef, Viola M J; Suonio, Eero; Dillner, Lena; Minozzi, Silvia; Bellisario, Cristina; Banzi, Rita; Zhao, Fang-Hui; Hillemanns, Peter; Anttila, Ahti
2014-02-01
Screening for human papillomavirus (HPV) infection is more effective in reducing the incidence of cervical cancer than screening using Pap smears. Moreover, HPV testing can be done on a vaginal sample self-taken by a woman, which offers an opportunity to improve screening coverage. However, the clinical accuracy of HPV testing on self-samples is not well-known. We assessed whether HPV testing on self-collected samples is equivalent to HPV testing on samples collected by clinicians. We identified relevant studies through a search of PubMed, Embase, and CENTRAL. Studies were eligible for inclusion if they fulfilled all of the following selection criteria: a cervical cell sample was self-collected by a woman followed by a sample taken by a clinician; a high-risk HPV test was done on the self-sample (index test) and HPV-testing or cytological interpretation was done on the specimen collected by the clinician (comparator tests); and the presence or absence of cervical intraepithelial neoplasia grade 2 (CIN2) or worse was verified by colposcopy and biopsy in all enrolled women or in women with one or more positive tests. The absolute accuracy for finding CIN2 or worse, or CIN grade 3 (CIN3) or worse of the index and comparator tests as well as the relative accuracy of the index versus the comparator tests were pooled using bivariate normal models and random effect models. We included data from 36 studies, which altogether enrolled 154 556 women. The absolute accuracy varied by clinical setting. In the context of screening, HPV testing on self-samples detected, on average, 76% (95% CI 69-82) of CIN2 or worse and 84% (72-92) of CIN3 or worse. The pooled absolute specificity to exclude CIN2 or worse was 86% (83-89) and 87% (84-90) to exclude CIN3 or worse. The variation of the relative accuracy of HPV testing on self-samples compared with tests on clinician-taken samples was low across settings, enabling pooling of the relative accuracy over all studies. The pooled sensitivity of HPV testing on self-samples was lower than HPV testing on a clinician-taken sample (ratio 0·88 [95% CI 0·85-0·91] for CIN2 or worse and 0·89 [0·83-0·96] for CIN3 or worse). Also specificity was lower in self-samples versus clinician-taken samples (ratio 0·96 [0·95-0·97] for CIN2 or worse and 0·96 [0·93-0·99] for CIN3 or worse). HPV testing with signal-based assays on self-samples was less sensitive and specific than testing on clinician-based samples. By contrast, some PCR-based HPV tests generally showed similar sensitivity on both self-samples and clinician-based samples. In screening programmes using signal-based assays, sampling by a clinician should be recommended. However, HPV testing on a self-sample can be suggested as an additional strategy to reach women not participating in the regular screening programme. Some PCR-based HPV tests could be considered for routine screening after careful piloting assessing feasibility, logistics, population compliance, and costs. The 7th Framework Programme of the European Commission, the Belgian Foundation against Cancer, the International Agency for Research on Cancer, and the German Guideline Program in Oncology. Copyright © 2014 Elsevier Ltd. All rights reserved.
Biophysical Interactions within Step-Pool Mountain Streams Following Wildfire
NASA Astrophysics Data System (ADS)
Parker, A.; Chin, A.; O'Dowd, A. P.
2014-12-01
Recovery of riverine ecosystems following disturbance is driven by a variety of interacting processes. Wildfires pose increasing disturbances to riverine landscapes, with rising frequencies and magnitudes owing to warming climates and increased fuel loads. The effects of wildfire include loss of vegetation, elevated runoff and flash floods, erosion and deposition, and changing biological habitats and communities. Understanding process interactions in post-fire landscapes is increasingly urgent for successful management and restoration of affected ecosystems. In steep channels, steps and pools provide prominent habitats for organisms and structural integrity in high energy environments. Step-pools are typically stable, responding to extreme events with recurrence intervals often exceeding 50 years. Once wildfire occurs, however, intensification of post-fire flood events can potentially overpower the inherent stability of these systems, with significant consequences for aquatic life and human well-being downstream. This study examined the short-term response of step-pool streams following the 2012 Waldo Canyon Fire in Colorado. We explored interacting feedbacks among geomorphology, hydrology, and ecology in the post-fire environment. At selected sites with varying burn severity, we established baseline conditions immediately after the fire with channel surveys, biological assessment using benthic macroinvertebrates, sediment analysis including pebble counts, and precipitation gauging. Repeat measurements after major storm events over several years enabled analysis of the interacting feedbacks among post-fire processes. We found that channels able to retain the step-pool structure changed less and facilitated recovery more readily. Step habitats maintained higher percentages of sensitive macroinvertebrate taxa compared to pools through post-fire floods. Sites burned with high severity experienced greater reduction in the percentage of sensitive taxa. The decimation of macroinvertebrates closely coincides with the physical destruction of the step-pool morphology. The role that step-pools play in enhancing the ecological quality of fluvial systems, therefore, provides a key focus for effective management and restoration of aquatic resources following wildfires.
Cyanuric acid (CA) has found application as a chlorine stabilizer in pool waters. The National Swimming Pool Foundation recommends CA levels between 30-50 ppm and a chlorine residual of 1.0-3.0 ppm. These chlorine levels are needed to destroy harmful pathogenic organisms. Develo...
Apelseth, Torunn O; Kvalheim, Venny L; Kristoffersen, Einar K
2016-05-01
Allergic transfusion reactions (ATRs) present with a broad range of symptoms probably caused by mediators released from mast cells and basophil granulocytes upon activation. Passive immunoglobulin (Ig)E sensitization may yield clinical symptoms and positive allergy tests. Unexpected findings of IgE antibodies in pooled solvent/detergent (S/D)-treated plasma (Octaplas, Octapharma) during routine analysis initiated an investigation of serum proteins. Consecutive batches of S/D-plasma transfused during September 2014 through March 2015 were investigated for IgE, IgG, IgA IgM, C3, C4, haptoglobin, anti-nuclear antibodies (ANAs), and red blood cell (RBC) antibodies. During the study period, 4203 S/D-plasma units were transfused. Nineteen (14 Octaplas A and five Octaplas AB) of 20 batches of S/D-plasma were included, representing 99.9% of total number of plasma units. A total of 0.4% of units and five batches reported ATRs. Concentrations of total IgE higher than expected values in adults (<120 kU/L) were observed in 18 of the 19 (95%) batches investigated (median concentration [quartiles], 161 [133-183]). Specific IgE antibodies (expected < 0.35 kilounits antigen [kUA]/L) against house dust mite (2.52 [1.01-5.09]), timothy (2.83 [2.48-3.24]), cat (1.13 [0.58-1.52]), dog (0.83 [0.50-1.05]), mugwort (0.69 [0.53-0.97]), birch (0.62 [0.28-0.92]), peanut (0.52 [0.29-075]), wheat (0.46 [0.33-0.69]), and latex (0.32 [0.21-0.53]) were also detected. IgG, IgA, IgM, C3, C4, and haptoglobin were within or below normal ranges. No RBC antibodies were observed, but 18% of batches showed low levels of ANA (anti-RNP). Specific IgE antibodies against airborne allergens, food allergens, and latex were detected in S/D-treated pooled plasma. © 2016 AABB.
Kitchen, A D; Newham, J A
2011-05-01
Whilst some of the assays used for serological screening of post-mortem blood samples from deceased tissue donors in some countries have been specifically validated by the manufacturer for this purpose, a significant number of those currently in use globally have not. Although specificity has previously been considered a problem in the screening of such samples, we believe that ensuring sensitivity is more important. The aim of this study was to validate a broader range of assays for the screening of post-mortem blood samples from deceased tissue donors. Six microplate immunoassays currently in use within National Health Service Blood and Transplant (NHSBT) for the screening of blood, tissue and stem cell donations were included. Representative samples from confirmed positive donors were titrated in screen negative post-mortem samples in parallel with normal pooled negative serum to determine if there was any inhibition with the post-mortem samples. There were no significant differences seen (P < 0.005) between the dilution curves obtained for the positive samples diluted in post-mortem samples and normal pooled sera. Although small numbers of samples were studied, it can be surmised that the post-mortem blood samples from deceased tissue donors, collected according to United Kingdom guidelines, are a suitable substrate for the assays evaluated. No diminution of reactivity was seen when dilution with sera from deceased donors was compared to dilution using pooled serum from live donors. In the absence of genuine low titre positive post-mortem samples, the use of samples spiked with various levels of target material provides a means of qualifying serological screening assays used by NHSBT for the screening of post-mortem blood samples from deceased tissue donors.
Providência, Rui; Grove, Erik Lerkevang; Husted, Steen; Barra, Sérgio; Boveda, Serge; Morais, João
2014-12-01
Previous studies evaluating the ability of novel oral anticoagulants (NOAC) to prevent thromboembolism in patients with non-valvular atrial fibrillation (AF) have identified differences between the efficacy and safety of the drugs tested. Whether these differences reflect differences in direct thrombin or Xa inhibition, different dosing regimens or specific aspects of each agent or trial has not yet been explored. A search was performed on MEDLINE, EMBASE and COCHRANE, and ongoing studies were tracked on clinicaltrials.gov. Phase III randomized controlled trials of direct thrombin inhibitors (DTI) and factor Xa inhibitors (FXaI) vs. warfarin in patients with AF were eligible. Data were pooled using random-effects, according to the Mantel-Haenszel model. Sensitivity analyses were performed on DTI, FXaI, once-daily and twice-daily regimens. Seven studies were pooled, including a total of 80,290 patients. Both DTI and FXaI outperformed warfarin regarding stroke or systemic embolism, intracranial bleeding, total and cardiovascular mortality. No significant differences were found between DTI and FXaI or between once-daily and twice-daily regimens. Some drugs performed worse than warfarin regarding some secondary endpoints, including: edoxaban 30 mg bid on ischaemic stroke, dabigatran on acute myocardial infarction, dabigatran 150 mg bid and rivaroxaban 20mgod on gastrointestinal bleeding. Our pooled data do not support the hypothesis of a significant class-effect of DTI or FXaI, nor the benefit of once-daily vs. twice-daily dosing in the setting of AF, reinforcing that the choice of NOAC should be adapted to the specific patient and focused on the agent itself, rather than the pharmacological class or dosing regimen.
Perfluoroalkyl substances and time to pregnancy in couples from Greenland, Poland and Ukraine.
Jørgensen, Kristian T; Specht, Ina O; Lenters, Virissa; Bach, Cathrine C; Rylander, Lars; Jönsson, Bo A G; Lindh, Christian H; Giwercman, Aleksander; Heederik, Dick; Toft, Gunnar; Bonde, Jens Peter
2014-12-22
Perfluoroalkyl substances (PFAS) are suggested to affect human fecundity through longer time to pregnancy (TTP). We studied the relationship between four abundant PFAS and TTP in pregnant women from Greenland, Poland and Ukraine representing varying PFAS exposures and pregnancy planning behaviors. We measured serum levels of perfluorooctanoic acid (PFOA), perfluorooctane sulfonate (PFOS), perfluorohexane sulfonic acid (PFHxS) and perfluorononanoic acid (PFNA) in 938 women from Greenland (448 women), Poland (203 women) and Ukraine (287 women). PFAS exposure was assessed on a continuous logarithm transformed scale and in country-specific tertiles. We used Cox discrete-time models and logistic regression to estimate fecundability ratios (FRs) and infertility (TTP >13 months) odds ratios (ORs), respectively, and 95% confidence intervals (CI) according to PFAS levels. Adjusted analyses of the association between PFAS and TTP were done for each study population and in a pooled sample. Higher PFNA levels were associated with longer TTP in the pooled sample (log-scale FR = 0.80; 95% CI 0.69-0.94) and specifically in women from Greenland (log-scale FR = 0.72; 95% CI 0.58-0.89). ORs for infertility were also increased in the pooled sample (log-scale OR = 1.53; 95% CI 1.08-2.15) and in women from Greenland (log-scale OR = 1.97; 95% CI 1.22-3.19). However, in a sensitivity analysis of primiparous women these associations could not be replicated. Associations with PFNA were weaker for women from Poland and Ukraine. PFOS, PFOA and PFHxS were not consistently associated with TTP. Findings do not provide consistent evidence that environmental exposure to PFAS is impairing female fecundity by delaying time taken to conceive.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amai, W.; Espinoza, J. Jr.; Fletcher, D.R.
1997-06-01
This Software Requirements Specification (SRS) describes the features to be provided by the software for the GIS-T/ISTEA Pooled Fund Study Phase C Linear Referencing Engine project. This document conforms to the recommendations of IEEE Standard 830-1984, IEEE Guide to Software Requirements Specification (Institute of Electrical and Electronics Engineers, Inc., 1984). The software specified in this SRS is a proof-of-concept implementation of the Linear Referencing Engine as described in the GIS-T/ISTEA pooled Fund Study Phase B Summary, specifically Sheet 13 of the Phase B object model. The software allows an operator to convert between two linear referencing methods and a datummore » network.« less
Trail-following in termites: Evidence for a multicomponent system.
Kaib, M; Bruinsma, O; Leuthold, R H
1982-09-01
Several African termite species from different subfamilies and different habitats are sensitive to trail-active extracts or to naturally laid trails from other species. Using single-extract bioassays, it is shown that the response threshold for trail-following is nearly identical for all tested species (except forHodotermes mossambicus). However, when termite workers have a choice between trails from their own species and from other species, conspecific trail-following is exclusively observed. This phenomenon can be counteracted by dilution (1∶10) of the conspecific trail-pheromone extract. Tests of the trail activity of various synthetic alcohols show that among these, the highest sensitivity of termite workers is to (Z)-3-dodecen-1-ol. Based on our experimental data, we postulate that, in addition to a generally active trail-pheromone constituent (an unsaturated primary C12 alcohol) or a pool of chemically closely related alcohols, other species-specific components are present in termite trails.
The Diagnostic Accuracy of the Berg Balance Scale in Predicting Falls.
Park, Seong-Hi; Lee, Young-Shin
2017-11-01
This study aimed to evaluate the predictive validity of the Berg Balance Scale (BBS) as a screening tool for fall risks among those with varied levels of balance. A total of 21 studies reporting predictive validity of the BBS of fall risk were meta-analyzed. With regard to the overall predictive validity of the BBS, the pooled sensitivity and specificity were 0.72 and 0.73, respectively; the accuracy curve area was 0.84. The findings showed statistical heterogeneity among studies. Among the sub-groups, the age group of those younger than 65 years, those with neuromuscular disease, those with 2+ falls, and those with a cutoff point of 45 to 49 showed better sensitivity with statistically less heterogeneity. The empirical evidence indicates that the BBS is a suitable tool to screen for the risk of falls and shows good predictability when used with the appropriate criteria and applied to those with neuromuscular disease.
Chen, Hong-Ming; Armstrong, Zachary; Hallam, Steven J; Withers, Stephen G
2016-02-08
Screening of large enzyme libraries such as those derived from metagenomic sources requires sensitive substrates. Fluorogenic glycosides typically offer the best sensitivity but typically must be used in a stopped format to generate good signal. Use of fluorescent phenols of pKa < 7, such as halogenated coumarins, allows direct screening at neutral pH. The synthesis and characterisation of a set of nine different glycosides of 6-chloro-4-methylumbelliferone are described. The use of these substrates in a pooled format for screening of expressed metagenomic libraries yielded a "hit rate" of 1 in 60. Hits were then readily deconvoluted with the individual substrates in a single plate to identify specific activities within each clone. The use of such a collection of substrates greatly accelerates the screening process. Copyright © 2015 Elsevier Ltd. All rights reserved.
Combination of the non-invasive tests for the diagnosis of endometriosis.
Nisenblat, Vicki; Prentice, Lucy; Bossuyt, Patrick M M; Farquhar, Cindy; Hull, M Louise; Johnson, Neil
2016-07-13
About 10% of women of reproductive age suffer from endometriosis, a costly chronic disease causing pelvic pain and subfertility. Laparoscopy is the gold standard diagnostic test for endometriosis, but is expensive and carries surgical risks. Currently, there are no non-invasive tests available in clinical practice to accurately diagnose endometriosis. This review assessed the diagnostic accuracy of combinations of different non-invasive testing modalities for endometriosis and provided a summary of all the reviews in the non-invasive tests for endometriosis series. To estimate the diagnostic accuracy of any combination of non-invasive tests for the diagnosis of pelvic endometriosis (peritoneal and/or ovarian or deep infiltrating) compared to surgical diagnosis as a reference standard. The combined tests were evaluated as replacement tests for diagnostic surgery and triage tests to assist decision-making to undertake diagnostic surgery for endometriosis. We did not restrict the searches to particular study designs, language or publication dates. We searched CENTRAL to July 2015, MEDLINE and EMBASE to May 2015, as well as the following databases to April 2015: CINAHL, PsycINFO, Web of Science, LILACS, OAIster, TRIP, ClinicalTrials.gov, DARE and PubMed. We considered published, peer-reviewed, randomised controlled or cross-sectional studies of any size, including prospectively collected samples from any population of women of reproductive age suspected of having one or more of the following target conditions: ovarian, peritoneal or deep infiltrating endometriosis (DIE). We included studies comparing the diagnostic test accuracy of a combination of several testing modalities with the findings of surgical visualisation of endometriotic lesions. Three review authors independently collected and performed a quality assessment of the data from each study by using the QUADAS-2 tool. For each test, the data were classified as positive or negative for the surgical detection of endometriosis and sensitivity and specificity estimates were calculated. The bivariate model was planned to obtain pooled estimates of sensitivity and specificity whenever sufficient data were available. The predetermined criteria for a clinically useful test to replace diagnostic surgery were a sensitivity of 0.94 and a specificity of 0.79 to detect endometriosis. We set the criteria for triage tests at a sensitivity of 0.95 and above and a specificity of 0.50 and above, which 'rules out' the diagnosis with high accuracy if there is a negative test result (SnOUT test), or a sensitivity of 0.50 and above and a specificity of 0.95 and above, which 'rules in' the diagnosis with high accuracy if there is a positive result (SpIN test). Eleven eligible studies included 1339 participants. All the studies were of poor methodological quality. Seven studies evaluated pelvic endometriosis, one study considered DIE and/or ovarian endometrioma, two studies differentiated endometrioma from other ovarian cysts and one study addressed mapping DIE at specific anatomical sites. Fifteen different diagnostic combinations were assessed, including blood, urinary or endometrial biomarkers, transvaginal ultrasound (TVUS) and clinical history or examination. We did not pool estimates of sensitivity and specificity, as each study analysed independent combinations of the non-invasive tests.Tests that met the criteria for a replacement test were: a combination of serum IL-6 (cut-off >15.4 pg/ml) and endometrial PGP 9.5 for pelvic endometriosis (sensitivity 1.00 (95% confidence interval (CI) 0.91 to 1.00), specificity 0.93 (95% CI, 0.80, 0.98) and the combination of vaginal examination and transvaginal ultrasound (TVUS) for rectal endometriosis (sensitivity 0.96 (95% CI 0.86 to 0.99), specificity 0.98 (95% CI 0.94 to 1.00)). Tests that met the criteria for SpIN triage tests for pelvic endometriosis were: 1. a multiplication of urine vitamin-D-binding protein (VDBP) and serum CA-125 (cut-off >2755) (sensitivity 0.74 (95% CI 0.60 to 0.84), specificity 0.97 (95% CI 0.86 to 1.00)) and 2. a combination of history (length of menses), serum CA-125 (cut-off >35 U/ml) and endometrial leukocytes (sensitivity 0.61 (95% CI 0.54 to 0.69), specificity 0.95 (95% CI 0.91 to 0.98)). For endometrioma, the following combinations qualified as SpIN test: 1. TVUS and either serum CA-125 (cut-off ≥25 U/ml) or CA 19.9 (cut-off ≥12 U/ml) (sensitivity 0.79 (95% CI 0.64 to 0.91), specificity 0.97 (95% CI 0.91 to 1.00)); 2. TVUS and serum CA 19.9 (cut-off ≥12 U/ml) (sensitivity 0.54 (95% CI 0.37 to 0.70), specificity 0.97 (95% CI 0.91 to 1.0)); 3-4. TVUS and serum CA-125 (cut-off ≥20 U/ml or cut-off ≥25 U/ml) (sensitivity 0.69 (95% CI 0.49 to 0.85), specificity 0.96 (95% CI 0.88 to 0.99)); 5. TVUS and serum CA-125 (cut-off ≥35 U/ml) (sensitivity 0.52 (95% CI 0.33 to 0.71), specificity 0.97 (95% CI 0.90 to 1.00)). A combination of vaginal examination and TVUS reached the threshold for a SpIN test for obliterated pouch of Douglas (sensitivity 0.87 (95% CI 0.69 to 0.96), specificity 0.98 (95% CI 0.95 to 1.00)), vaginal wall endometriosis (sensitivity 0.82 (95% CI 0.60 to 0.95), specificity 0.99 (95% CI 0.97 to 1.0)) and rectovaginal septum endometriosis (sensitivity 0.88 (95% CI 0.47 to 1.00), specificity 0.99 (95% CI 0.96 to 1.00)).All the tests were evaluated in individual studies and displayed wide CIs. Due to the heterogeneity and high risk of bias of the included studies, the clinical utility of the studied combination diagnostic tests for endometriosis remains unclear. None of the biomarkers evaluated in this review could be evaluated in a meaningful way and there was insufficient or poor-quality evidence. Laparoscopy remains the gold standard for the diagnosis of endometriosis and using any non-invasive tests should only be undertaken in a research setting.
Bittner, Mario; Faes, Livia; Boehni, Sophie C; Bachmann, Lucas M; Schlingemann, Reinier O; Schmid, Martin K
2016-12-07
Colour Doppler analysis of ophthalmic vessels has been proposed as a promising tool in the diagnosis of various eye diseases, but the available diagnostic evidence has not yet been assessed systematically. We performed a comprehensive systematic review of the literature on the diagnostic properties of Colour Doppler imaging (CDI) assessing ophthalmic vessels and provide an inventory of the available evidence. Eligible papers were searched electronically in (Pre) Medline, Embase and Scopus, and via cross-checking of reference lists. The minimum requirement to be included was the availability of original data and the possibility to construct a two-by-two table. Study selection, critical appraisal using the QUADAS II instrument and extraction of salient study characteristics was made in duplicate. Sensitivity and specificity was computed for each study. We included 11 studies (15 two-by-two tables) of moderate methodological quality enrolling 820 participants (range 30 to 118). In 44.4% participants were female (range 37-59% in specific subgroups). CDI was assessed for internal carotid stenosis, diabetic retinopathy, glaucoma, and branch or central retinal vein occlusion diagnosis. There was insufficient data to pool the results for specific illnesses. For the assessments of ophthalmic arteries, mean sensitivity was 0.69 (range 0.27-0.96) with a corresponding mean specificity of 0.83 (range 0.70-0.96). Mean sensitivity of the central retinal artery assessments was 0.58 (range 0.31-0.84) and the corresponding mean specificity was 0.82 (range 0.63-0.94). Robust assessments of the diagnostic value of colour Doppler analysis remain uncommon, limiting the possibilities to extrapolate its true potential for clinical practice. PROSPERO 2014:CRD42014014027.
Li, Rui; Liu, Jianjun; Xue, Huiping; Huang, Gang
2012-10-15
The measurement of fecal tumor M2-pyruvate kinase (PKM2), overexpressed in tumor cells, has been proposed as a novel tool for detecting colorectal cancer (CRC). However, the sensitivity and specificity of this test varied among studies. The aim of this meta-analysis was to determine the diagnostic accuracy of fecal PKM2 for CRC and to evaluate its utility in the CRC screening. It was compared to guaiac fecal occult blood test (gFOBT) or immunological fecal occult blood test (iFOBT). Through comprehensive literature search, 10 studies met the inclusion criteria and were included. Summary estimates for sensitivity and specificity were calculated by using the bivariate random effect model. The hierarchical summary receiver operating characteristic curve was also undertaken. The overall sensitivity and specificity of fecal PKM2 for detecting CRC were 79% (95% CI = 75-83%) and 81% (95% CI = 73-87%), respectively. The summary positive predictive value and negative predictive value were 74% (95% CI = 56-87%) and 86% (95% CI = 79-91%), respectively. The pooled diagnostic odds ratio was 16 (95% CI = 10-26). In head-to-head comparison, the diagnostic odds ratio of PKM2 and gFOBT for CRC were 10.167 (95% CI = 5.992-17.250) and 6.557 (95% CI = 3.467-12.403), respectively. The diagnostic odds ratio of PKM2 and iFOBT for CRC were 9.542 (95% CI = 5.893-15.452) and 67.248 (95% CI = 16.194-279.26), respectively. The fecal PKM2 test was a diagnostic tool with moderate sensitivity and specificity for detecting CRC. Its diagnostic efficiency was similar to that of gFOBT. Because of its relatively low specificity and positive predict value, fecal PKM2 was not recommended used alone as a screening tool for CRC. Copyright © 2012 UICC.
Carbon sequestration in harvested wood products.
K. Skog
2011-01-01
This section quantifies the net changes in C stocks in the five forest C pools and two harvested wood pools. The net change in stocks for each pool is estimated, and then the changes in stocks are summed over all pools to estimate total net flux. The focus on C implies that all C-based greenhouse gases are included, and the focus on stock change suggests that specific...
Diagnostic value of survivin for malignant pleural effusion: a clinical study and meta-analysis.
Tian, Panwen; Shen, Yongchun; Wan, Chun; Yang, Ting; An, Jing; Yi, Qun; Chen, Lei; Wang, Tao; Wang, Ye; Wen, Fuqiang
2014-01-01
To investigate the diagnostic accuracy of survivin for malignant pleural effusion (MPE). Pleural effusion samples were collected from 40 MPE patients and 45 non-MPE patients. Pleural levels of survivin were measured by ELISA. Literature search was performed in Pubmed and Embase to identify studies regarding the usefulness of survivin to diagnose MPE. Data were retrieved and the pooled sensitivity, specificity and other diagnostic indexes were calculated. The summary receiver operating characteristics (SROC) curve was used to determine the overall diagnostic accuracy. The pleural levels of survivin were higher in MPE patients than non-MPE patients (844.17 ± 358.30 vs. 508.08 ± 169.58 pg/ml, P < 0.05), at a cut-off value of 683.2 pg/ml, the sensitivity and specificity were 57.50% and 88.89%, respectively. A total of six studies were included in present meta-analysis, the overall diagnostic estimates were: sensitivity 0.74 (95% CI: 0.59-0.85); specificity, 0.85 (95% CI: 0.79-0.89); positive likelihood ratio, 4.79 (95% CI: 3.48-6.61); negative likelihood ratio, 0.31 (95% CI: 0.19-0.50), and diagnostic odds ratio, 15.59 (95% CI: 7.69-31.61). The area under SROC curve was 0.86 (95% CI: 0.82-0.89). Our study confirms that the pleural survivin plays a role in the diagnosis of MPE. More studies at a large scale should be performed to validate our findings.
Circulating microRNAs in Pancreatic Juice as Candidate Biomarkers of Pancreatic Cancer
Wang, Jin; Raimondo, Massimo; Guha, Sushovan; Chen, Jinyun; Diao, Lixia; Dong, Xiaoqun; Wallace, Michael B.; Killary, Ann M.; Frazier, Marsha L.; Woodward, Timothy A.; Wang, Jing; Sen, Subrata
2014-01-01
Development of sensitive and specific biomarkers, preferably those circulating in body fluids is critical for early diagnosis of cancer. This study performed profiling of microRNAs (miRNAs) in exocrine pancreatic secretions (pancreatic juice) by microarray analysis utilizing pancreatic juice from 6 pancreatic ductal adenocarcinoma (PDAC) patients and two pooled samples from 6 non-pancreatic, non-healthy (NPNH) as controls. Differentially circulating miRNAs were subsequently validated in 88 pancreatic juice samples from 50 PDAC, 19 chronic pancreatitis (CP) patients and 19 NPNH controls. A marked difference in the profiles of four circulating miRNAs (miR-205, miR-210, miR-492, and miR-1427) was observed in pancreatic juice collected from patients with PDAC and those without pancreatic disease. Elevated levels of the four miRNAs together predicted PDAC with a specificity of 88% and sensitivity of 87%. Inclusion of serum CA19-9 level increased the sensitivity to 91% and the specificity to 100%. Enrichment of the four miRNAs in pancreatic juice was associated with decreased OS, as was the combination of miR-205 and miR-210. Higher contents of miR-205 and miR-210 were also associated with lymph node metastasis. Elevated levels of circulating miR-205, miR-210, miR-492, and miR-1247 in pancreatic juice are, therefore, promising candidate biomarkers of disease and poor prognosis in patients with PDAC. PMID:25258651
Murai, Kiyokazu; Lehenbauer, Terry W; Champagne, John D; Glenn, Kathy; Aly, Sharif S
2014-03-01
Diagnostic strategies to detect contagious mastitis caused by Mycoplasma bovis, Staphylococcus aureus, and Streptococcus agalactiae in dairy herds during an outbreak have been minimally studied with regard to cost and diagnostic sensitivity. The objective of this cross-sectional study was to compare the cost-effectiveness of diagnostic strategies for identification of infected cows in two California dairy herds during contagious mastitis outbreaks. M. bovis was investigated in a subset of a herd (n=1210 cows) with an estimated prevalence of 2.8% (95% CI=1.9, 3.7), whereas Staph. aureus and Strep. agalactiae were studied in a second herd (n=351 cows) with an estimated prevalence of 3.4% (95% CI=1.5, 5.3) and 16.8% (95% CI=12.9, 20.7), respectively. Diagnostic strategies involved a combination of testing stages that utilized bacterial culture, quantitative real-time PCR (qPCR), or both. Strategies were applied to individual or pooled samples of 5, 10, 50 or 100 samples. Culture was considered the gold standard for sensitivity estimation of each strategy. The reference strategy was the strategy with the lowest cost per culture-positive cow which for both M. bovis and Strep. agalactiae consisted of 2 stages, culture of samples in pools of 5 followed by culture of individual samples in positive pools with a sensitivity of 73.5% (95% CI: 55.6, 87.1) and 96.6% (95% CI: 27.7, 84.8), respectively. The reference strategy for Staph. aureus consisted of 3 stages, culture of individual samples in pools of 100 (stage 1), culture constituents of those positive from stage 1 in pools of 5 (stage 2), culture constituents of those positive from stage 2 individually (stage 3) which resulted in a sensitivity of 58.3% (95% CI: 88.3, 99.6). The most cost-effective alternative to the reference strategy was whole herd milk culture for all 3 pathogens. QPCR testing was a component of the second most cost-effective alternative for M. bovis and the third most cost-effective alternatives for the 3 pathogens. A stochastic model was used to assess the effect of prevalence or herd size on the cost-effectiveness of diagnostic strategies. In the current study, increasing the prevalence of mastitis did not alter the ranking of strategies by cost-effectiveness. However, larger herds could benefit from testing larger pools such as 50 or 100 samples to improve cost-effectiveness. Several diagnostic strategy options exist to identify contagious mastitis in herds, decisions should be based on cost and sensitivity of the strategies available. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Attracting Cutting-Edge Skills Through Reserve Component Participation
2003-01-01
specific recruitment pool of faculty and students within these institutions who possess the state-of-the- art science and technical skills or the most...identify a specific recruitment pool of faculty and students within these institutions who possess the state-of-the- art science and technical skills or
Wyatt, M.C.; Beswick, A.D.; Kunutsor, S.K.; Wilson, M.J.; Whitehouse, M.R.; Blom, A.W.
2016-01-01
Background: Synovial biomarkers have recently been adopted as diagnostic tools for periprosthetic joint infection (PJI), but their utility is uncertain. The purpose of this systematic review and meta-analysis was to synthesize the evidence on the accuracy of the alpha-defensin immunoassay and leukocyte esterase colorimetric strip test for the diagnosis of PJI compared with the Musculoskeletal Infection Society diagnostic criteria. Methods: We performed a systematic review to identify diagnostic technique studies evaluating the accuracy of alpha-defensin or leukocyte esterase in the diagnosis of PJI. MEDLINE and Embase on Ovid, ACM, ADS, arXiv, CERN DS (Conseil Européen pour la Recherche Nucléaire Document Server), CrossRef DOI (Digital Object Identifier), DBLP (Digital Bibliography & Library Project), Espacenet, Google Scholar, Gutenberg, HighWire, IEEE Xplore (Institute of Electrical and Electronics Engineers digital library), INSPIRE, JSTOR (Journal Storage), OAlster (Open Archives Initiative Protocol for Metadata Harvesting), Open Content, Pubget, PubMed, and Web of Science were searched for appropriate studies indexed from inception until May 30, 2015, along with unpublished or gray literature. The classification of studies and data extraction were performed independently by 2 reviewers. Data extraction permitted meta-analysis of sensitivity and specificity with construction of receiver operating characteristic curves for each test. Results: We included 11 eligible studies. The pooled diagnostic sensitivity and specificity of alpha-defensin (6 studies) for PJI were 1.00 (95% confidence interval [CI], 0.82 to 1.00) and 0.96 (95% CI, 0.89 to 0.99), respectively. The area under the curve (AUC) for alpha-defensin and PJI was 0.99 (95% CI, 0.98 to 1.00). The pooled diagnostic sensitivity and specificity of leukocyte esterase (5 studies) for PJI were 0.81 (95% CI, 0.49 to 0.95) and 0.97 (95% CI, 0.82 to 0.99), respectively. The AUC for leukocyte esterase and PJI was 0.97 (95% CI, 0.95 to 0.98). There was substantial heterogeneity among studies for both diagnostic tests. Conclusions: The diagnostic accuracy for PJI was high for both tests. Given the limited number of studies and the large cost difference between the tests, more independent research on these tests is warranted. Level of Evidence: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence. PMID:27307359
A Survey of Enzymatic Activity in Commercially Available Pool and Spa Products
USDA-ARS?s Scientific Manuscript database
Many pool water treatment products currently available commercially claim that they work effectively by possessing enzyme activity (specifically lipase) that degrades common oil (lipid) contaminants found in pool water. Currently, there is no standard in measuring the enzymatic activity of these enz...
Davelois, Kelly; Escalante, Hermes; Jara, César
2016-01-01
. To determine the diagnostic yield using western blotting to simultaneously detect antibodies in patients with human cysticercosis, hydatidosis, and human fascioliasis. Materials and methods . Cross-sectional study of diagnostic yield assessment. Excretory/secretory antigens were obtained from Taenia solium larvae, Echinococcus granulosus cysts, and the adult flukes of Fasciola hepática, which were then separated using the polyacrylamide gel electrophoresis technique, transferred, and attached to a nitrocellulose membrane to be probed with sera from the patient infected with the three parasites. The sensitivity of the technique was assessed using 300 individual serum samples, 60 pools of two parasites, and 20 pools of three parasites with 75 sera from patients with other parasites, 10 from patients with other diseases, and 15 from patients without parasites. Results . The technique revealed 13 glycoproteins (GP): GP 35, 31, 24, 23, 18, 17, 14, and 13 kDa for cysticercosis; GP 8, 16, and 21 kDa for hydatidosis; and GP 17 and 23 kDa for fascioliasis. The test detected the presence of antibodies with a sensitivity of 96% (95% confidence interval [CI] = 94.62-98.54%) in the detection of one or the thirteen bands, a specificity of 100% (95% CI = 99.50-100.00%); individually, there was a sensitivity for cysticercosis of 97% (95% CI = 93.16-100.00%), for hydatidosis of 94% (95% CI = 88.85-99.15%) and for fascioliasis of 96% (95% CI = 91.66-100.00%). Conclusions . Western blotting is effective in the simultaneous detection of antibodies in patients with human cysticercosis, hydatidosis, and fascioliasis, and it can be used as a diagnostic test to either rule out or confirm the presence of antibodies in endemic areas.
Modification of CMV DNA detection from dried blood spots for diagnosing congenital CMV infection.
Binda, Sandro; Caroppo, Simona; Didò, Patrizia; Primache, Valeria; Veronesi, Licia; Calvario, Agata; Piana, Andrea; Barbi, Maria
2004-07-01
Detection of viral DNA in dried blood spots using the Guthrie card (DBS test) is a reliable and practical method of diagnosing congenital cytomegalovirus (CMV) infection. The test lends itself to epidemiological studies to establish the prevalence of the infection, but also to neonatal screening for secondary prevention of sequelae. These applications would be facilitated if it were possible to use smaller samples and do the test on pools of individual cases. To ascertain whether doing the test on smaller, pooled samples still accurately identifies neonates with congenital CMV infection. We tested DBS from: (A) 39 laboratory reference cases; (B) 156 neonates suspected of having congenital CMV infection; (C) 119 children examined for the retrospective diagnosis of congenital CMV; (D) mock specimens prepared with known amounts of viral DNA. The test using only one third of the usual amount of dried blood was 100% sensitive and specific compared to the standard DBS test (A) and to viral isolation (A and B). Pools of three single cases gave the same results as viral isolation (B) and the small-sample test (B and C). All the versions of the test gave a detection limit of 400 copies/ml. The modified procedure can accurately diagnose congenital CMV infection. It achieves savings in both the patient material and the costs of testing.
Context-specific effects of musical expertise on audiovisual integration
Bishop, Laura; Goebl, Werner
2014-01-01
Ensemble musicians exchange auditory and visual signals that can facilitate interpersonal synchronization. Musical expertise improves how precisely auditory and visual signals are perceptually integrated and increases sensitivity to asynchrony between them. Whether expertise improves sensitivity to audiovisual asynchrony in all instrumental contexts or only in those using sound-producing gestures that are within an observer's own motor repertoire is unclear. This study tested the hypothesis that musicians are more sensitive to audiovisual asynchrony in performances featuring their own instrument than in performances featuring other instruments. Short clips were extracted from audio-video recordings of clarinet, piano, and violin performances and presented to highly-skilled clarinetists, pianists, and violinists. Clips either maintained the audiovisual synchrony present in the original recording or were modified so that the video led or lagged behind the audio. Participants indicated whether the audio and video channels in each clip were synchronized. The range of asynchronies most often endorsed as synchronized was assessed as a measure of participants' sensitivities to audiovisual asynchrony. A positive relationship was observed between musical training and sensitivity, with data pooled across stimuli. While participants across expertise groups detected asynchronies most readily in piano stimuli and least readily in violin stimuli, pianists showed significantly better performance for piano stimuli than for either clarinet or violin. These findings suggest that, to an extent, the effects of expertise on audiovisual integration can be instrument-specific; however, the nature of the sound-producing gestures that are observed has a substantial effect on how readily asynchrony is detected as well. PMID:25324819
NASA Astrophysics Data System (ADS)
Kwiatkowski, Lester; Caldeira, Ken
2015-04-01
Anthropogenic emissions of CO2 and invasion of part of this CO2 into the oceans results in a decrease in seawater pH and a lowering of the calcium carbonate saturation state. The historic and projected decrease of the calcium carbonate saturation state of seawater has the potential to compromise the ability of many marine calcifying organisms to form their calcium carbonate shells or skeletons and is likely to have significant ocean ecosystem impacts over the 21st Century. In laboratory manipulations temperate calcifying organisms have been shown to exhibit reduced calcification as a result of CO2 addition. However, very few experiments have observed how calcification in temperate systems responds to natural variations in seawater carbonate chemistry. We assess the community level sensitivity of Californian tidal pool calcification rates to variability in the calcium carbonate saturation state. Our tidal pool study sites at Bodega Bay in Northern California experience extreme variation in low tide carbonate saturation state due to photosynthetic activity and the time at which the pools are isolated from the open ocean. During our study period, we observed aragonite saturation levels ranging from 0.5 to 9. Photosynthetic activity is largely dependent on temperature and photosynthetic active radiation which vary on a diurnal timescale whereas the time at which pools are isolated from open seawater, and thus the amount by which tide pool carbonate chemistry differs from that of open ocean waters, is largely a consequence of tidal period which varies on a lunar cycle. Because there are substantial uncorrelated components of light, temperature, and seawater carbonate chemistry in our data, one can separate the influence of carbonate saturation state on calcification from the influence of temperature and PAR. This provides an opportunity to characterise the short-timescale sensitivity of tidal pool calcification rates to changes in carbonate saturation state. We show that on such timescales community level rates of daytime calcification are not strongly influenced by variability in carbonate saturation state. This suggests that these intertidal communities may be more resilient to projected ocean acidification than previously thought, although extending this work to consider longer timescales would be required to more firmly support this hypothesis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khairallah, Saad A.; Anderson, Andrew T.; Rubenchik, Alexander
Our study demonstrates the significant effect of the recoil pressure and Marangoni convection in laser powder bed fusion (L-PBF) of 316L stainless steel. A three-dimensional high fidelity powder-scale model reveals how the strong dynamical melt flow generates pore defects, material spattering (sparking), and denudation zones. The melt track is divided into three sections: a topological depression, a transition and a tail region, each being the location of specific physical effects. The inclusion of laser ray-tracing energy deposition in the powder-scale model improves over traditional volumetric energy deposition. It enables partial particle melting, which impacts pore defects in the denudation zone.more » Different pore formation mechanisms are observed at the edge of a scan track, at the melt pool bottom (during collapse of the pool depression), and at the end of the melt track (during laser power ramp down). Finally, we discuss remedies to these undesirable pores are discussed. The results are validated against the experiments and the sensitivity to laser absorptivity.« less
Jannotti-Passos, Liana Konovaloffi; Dos Santos Carvalho, Omar
2017-01-01
The low stringency-polymerase chain reaction (LS-PCR) and loop-mediated isothermal amplification (LAMP) assays were used to detect the presence of S. mansoni DNA in (1) Brazilian intermediate hosts (Biomphalaria glabrata, B. straminea, and B. tenagophila) with patent S. mansoni infections, (2) B. glabrata snails with prepatent S. mansoni infections, (3) various mixtures of infected and noninfected snails; and (4) snails infected with other trematode species. The assays showed high sensitivity and specificity and could detect S. mansoni DNA when one positive snail was included in a pool of 1,000 negative specimens of Biomphalaria. These molecular approaches can provide a low-cost, effective, and rapid method for detecting the presence of S. mansoni in pooled samples of field-collected Biomphalaria. These assays should aid mapping of transmission sites in endemic areas, especially in low prevalence regions and improve schistosomiasis surveillance. It will be a useful tool to monitor low infection rates of snails in areas where control interventions are leading towards the elimination of schistosomiasis. PMID:28246533
Khairallah, Saad A.; Anderson, Andrew T.; Rubenchik, Alexander; ...
2016-02-23
Our study demonstrates the significant effect of the recoil pressure and Marangoni convection in laser powder bed fusion (L-PBF) of 316L stainless steel. A three-dimensional high fidelity powder-scale model reveals how the strong dynamical melt flow generates pore defects, material spattering (sparking), and denudation zones. The melt track is divided into three sections: a topological depression, a transition and a tail region, each being the location of specific physical effects. The inclusion of laser ray-tracing energy deposition in the powder-scale model improves over traditional volumetric energy deposition. It enables partial particle melting, which impacts pore defects in the denudation zone.more » Different pore formation mechanisms are observed at the edge of a scan track, at the melt pool bottom (during collapse of the pool depression), and at the end of the melt track (during laser power ramp down). Finally, we discuss remedies to these undesirable pores are discussed. The results are validated against the experiments and the sensitivity to laser absorptivity.« less
Temporal variability in chlorophyll fluorescence of back-reef corals in Ofu, American Samoa
Piniak, G.A.; Brown, E.K.
2009-01-01
Change in the yield of chlorophyll a fluorescence is a common indicator of thermal stress in corals. The present study reports temporal variability in quantum yield measurements for 10 coral species in Ofu, American Samoa - a place known to experience elevated and variable seawater temperatures. In winter, the zooxanthellae generally had higher dark-adapted maximum quantum yield (F v/Fm), higher light- adapted effective quantum yield (??F/F'm), and lower relative electron transport rates (rETR) than in the summer. Temporal changes appeared unrelated to the expected bleaching sensitivity of corals. All species surveyed, with the exception of Montipora grisea, demonstrated significant temporal changes in the three fluorescence parameters. Fluorescence responses were influenced by the microhabitat - temporal differences in fluorescence parameters were usually observed in the habitat with a more variable temperature regime (pool 300), while differences in Fv/Fm between species were observed only in the more environmentally stable habitat (pool 400). Such species-specific responses and microhabitat variability should be considered when attempting to determine whether observed in situ changes are normal seasonal changes or early signs of bleaching. ?? 2009 Marine Biological Laboratory.
López-Gutiérrez, Borja; Dinglasan, Rhoel R.
2017-01-01
The obligate intracellular lifestyle of Plasmodium falciparum and the difficulties in obtaining sufficient amounts of biological material have hampered the study of specific metabolic pathways in the malaria parasite. Thus, for example, the pools of sugar nucleotides required to fuel glycosylation reactions have never been studied in-depth in well-synchronized asexual parasites or in other stages of its life cycle. These metabolites are of critical importance, especially considering the renewed interest in the presence of N-, O-, and other glycans in key parasite proteins. In this work, we adapted a liquid chromatography tandem mass spectrometry (LC-MS/MS) method based on the use of porous graphitic carbon (PGC) columns and MS-friendly solvents to quantify sugar nucleotides in the malaria parasite. We report the thorough quantification of the pools of these metabolites throughout the intraerythrocytic cycle of P. falciparum. The sensitivity of the method enabled, for the first time, the targeted analysis of these glycosylation precursors in gametocytes, the parasite sexual stages that are transmissible to the mosquito vector. PMID:28104756
F18-FDG-PET for recurrent differentiated thyroid cancer: a systematic meta-analysis
Haslerud, Torjan; Brauckhoff, Katrin; Reisæter, Lars; Küfner Lein, Regina; Heinecke, Achim; Varhaug, Jan Erik
2015-01-01
Background Positron emission tomography (PET) with fluor-18-deoxy-glucose (FDG) is widely used for diagnosing recurrent or metastatic disease in patients with differentiated thyroid cancer (DTC). Purpose To assess the diagnostic accuracy of FDG-PET for DTC in patients after ablative therapy. Material and Methods A systematic search was conducted in Medline/PubMed, EMBASE, Cochrane Library, Web of Science, and Open Grey looking for all English-language original articles on the performance of FDG-PET in series of at least 20 patients with DTC having undergone ablative therapy including total thyroidectomy. Diagnostic performance measures were pooled using Reitsma’s bivariate model. Results Thirty-four publications between 1996 and 2014 met the inclusion criteria. Pooled sensitivity and specificity were 79.4% (95% confidence interval [CI], 73.9–84.1) and 79.4% (95% CI, 71.2–85.4), respectively, with an area under the curve of 0.858. Conclusion F18-FDG-PET is a useful method for detecting recurrent DTC in patients having undergone ablative therapy. PMID:26163534
A Novel Pan-Flavivirus Detection and Identification Assay Based on RT-qPCR and Microarray
Sachse, Konrad; Ziegler, Ute; Keller, Markus
2017-01-01
The genus Flavivirus includes arthropod-borne viruses responsible for a large number of infections in humans and economically important animals. While RT-PCR protocols for specific detection of most Flavivirus species are available, there has been also a demand for a broad-range Flavivirus assay covering all members of the genus. It is particularly challenging to balance specificity at genus level with equal sensitivity towards each target species. In the present study, a novel assay combining a SYBR Green-based RT-qPCR with a low-density DNA microarray has been developed. Validation experiments confirmed that the RT-qPCR exhibited roughly equal sensitivity of detection and quantification for all flaviviruses tested. These PCR products are subjected to hybridization on a microarray carrying 84 different oligonucleotide probes that represent all known Flavivirus species. This assay has been used as a screening and confirmation tool for Flavivirus presence in laboratory and field samples, and it performed successfully in international External Quality Assessment of NAT studies. Twenty-six Flavivirus strains were tested with the assay, showing equivalent or superior characteristics compared with the original or even with species-specific RT-PCRs. As an example, test results on West Nile virus detection in a panel of 340 mosquito pool samples from Greece are presented. PMID:28626758
Clarke, Brian; Ducharme, Anique; Giannetti, Nadia; Kim, Daniel; McDonald, Michael; Pflugfelder, Peter; Rajda, Miroslaw; Sénéchal, Mario; Stadnick, Ellie; Toma, Mustafa; Zieroth, Shelley; Isaac, Debra
2017-05-01
Transplantation of sensitized recipients has been associated with increased risk of post-transplant complications. In 2010, the Canadian Cardiac Transplant Network (CCTN) created a unique status listing for highly sensitized heart transplant candidates. Status 4S listing requires calculated panel-reactive antibody (cPRA) level >80% as the sole listing criteria and enables geographic expansion of the donor pool by providing national access. In this study, we describe patient characteristics and outcomes of those transplanted as Status 4S in Canada. Patients' characteristics and clinical outcomes were retrospectively collected from all 11 adult heart transplant centers in Canada. Ninety-six patients were listed Status 4S from January 2010 to September 2015. Fifty-two were transplanted as Status 4S. Of these 52 transplants, mean cPRA level was 93.4%, mean age was 47 years, 46% were male, 44% had dilated cardiomyopathy and 17% were re-transplanted for cardiac allograft vasculopathy (CAV). Blood group O comprised 42% and 53% had a left ventricular assist device as a bridge to transplant. Desensitization therapy occurred in 9 patients (17%). Over a mean follow-up period of 28 months (1 week to 5.3 years), 9 patients died (17%). Kaplan-Meier 1-year year survival is 86%. Two patients were treated for antibody-mediated rejection (AMR) in the first year post-transplant and 33% of patients had at least 1 ISHLT Grade ≥2R cellular rejection in the first year. Twenty-nine percent of patients developed de novo door-specific antibodies and demonstrated no correlation with AMR. Freedom from CAV at 1 year is 88.5% and at 5 years is 81.0%. Fifty-two percent of donor hearts originated from outside the recipients' geographic and organ donation organization. A national strategy of prioritizing highly sensitized heart transplant recipients has demonstrated effective expansion of the donor pool, acceptable short-term survival, freedom from CAV and low rates of clinically relevant AMR. However, we observed significantly higher rates of cellular rejection and de novo donor-specific antibody development in this population. It is currently unknown whether this will translate into poorer long-term outcome. Copyright © 2017 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Wei, James C-C; Baeten, Dominique; Sieper, Joachim; Deodhar, Atul; Bhosekar, Vaishali; Martin, Ruvie; Porter, Brian
2017-05-01
To evaluate efficacy and safety of secukinumab in Asian patients with active ankylosing spondylitis (AS) via a pooled subgroup analysis from two phase 3 studies, MEASURE 1 (NCT01358175) and MEASURE 2 (NCT01649375). In MEASURE 1, patients were randomized to intravenous secukinumab 10 mg/kg or placebo at baseline, Weeks 2 and 4, followed by subcutaneous (s.c.) secukinumab 150 mg, 75 mg or placebo every 4 weeks (q4w) at Week 8. In MEASURE 2, patients were randomized to s.c. secukinumab 150 mg, 75 mg or placebo at baseline, Weeks 1, 2 and 3, and q4w starting at Week 4. Efficacy outcomes were SpondyloArthritis International Society (ASAS) 20/40, high-sensitivity C-reactive protein (hsCRP), ASAS5/6, Bath Ankylosing Spondylitis Disease Activity Index, Short Form-36 physical component summary, AS quality of life (QoL), ASAS partial remission, and Ankylosing Spondylitis Disease Activity Score - CRP at Weeks 16 and 52. Due to lack of efficacy, the secukinumab 75 mg dose in MEASURE 2 was excluded from this pooled Asian subgroup analysis. Safety analysis included patients who received ≥ 1 dose of study treatment. Of 517 patients enrolled into the MEASURE studies, 69 (13.3%) were Asians: 46 in pooled secukinumab and 23 in placebo. At Week 16, ASAS20/40 responses in Asian patients were 69.6%/43.5% with pooled secukinumab versus 26.1%/17.4% with placebo, which were comparable with rates reported in the overall study population. Secukinumab improved predefined efficacy endpoints at Week 16, with responses sustained through Week 52. Secukinumab was well tolerated in Asian patients, with a safety profile consistent with that reported in the overall study population. Secukinumab improved signs and symptoms, physical function, and disease-specific QoL in Asian patients with active AS. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.
Holt, Kathryn E; Teo, Yik Y; Li, Heng; Nair, Satheesh; Dougan, Gordon; Wain, John; Parkhill, Julian
2009-08-15
Here, we present a method for estimating the frequencies of SNP alleles present within pooled samples of DNA using high-throughput short-read sequencing. The method was tested on real data from six strains of the highly monomorphic pathogen Salmonella Paratyphi A, sequenced individually and in a pool. A variety of read mapping and quality-weighting procedures were tested to determine the optimal parameters, which afforded > or =80% sensitivity of SNP detection and strong correlation with true SNP frequency at poolwide read depth of 40x, declining only slightly at read depths 20-40x. The method was implemented in Perl and relies on the opensource software Maq for read mapping and SNP calling. The Perl script is freely available from ftp://ftp.sanger.ac.uk/pub/pathogens/pools/.
Marcisz, Katarzyna; Fournier, Bertrand; Gilbert, Daniel; Lamentowicz, Mariusz; Mitchell, Edward A D
2014-05-01
Peatland testate amoebae (TA) are well-established bioindicators for depth to water table (DWT), but effects of hydrological changes on TA communities have never been tested experimentally. We tested this in a field experiment by placing Sphagnum carpets (15 cm diameter) collected in hummock, lawn and pool microsites (origin) at three local conditions (dry, moist and wet) using trenches dug in a peatland. One series of samples was seeded with microorganism extract from all microsites. TA community were analysed at T0: 8-2008, T1: 5-2009 and T2: 8-2009. We analysed the data using conditional inference trees, principal response curves (PRC) and DWT inferred from TA communities using a transfer function used for paleoecological reconstruction. Density declined from T0 to T1 and then increased sharply by T2. Species richness, Simpson diversity and Simpson evenness were lower at T2 than at T0 and T1. Seeded communities had higher species richness in pool samples at T0. Pool samples tended to have higher density, lower species richness, Simpson diversity and Simpson Evenness than hummock and/or lawn samples until T1. In the PRC, the effect of origin was significant at T0 and T1, but the effect faded away by T2. Seeding effect was strongest at T1 and lowest vanished by T2. Local condition effect was strong but not in line with the wetness gradient at T1 but started to reflect it by T2. Likewise, TA-inferred DWT started to match the experimental conditions by T2, but more so in hummock and lawn samples than in pool samples. This study confirmed that TA responds to hydrological changes over a 1-year period. However, sensitivity of TA to hydrological fluctuations, and thus the accuracy of inferred DWT changes, was habitat specific, pool TA communities being least responsive to environmental changes. Lawns and hummocks may be thus better suited than pools for paleoecological reconstructions. This, however, contrasts with the higher prediction error and species' tolerance for DWT with increasing dryness observed in transfer function models.
El-Osta, Hazem; Jani, Pushan; Mansour, Ali; Rascoe, Philip; Jafri, Syed
2018-04-23
An accurate assessment of the mediastinal lymph nodes status is essential in the staging and treatment planning of potentially resectable non-small cell lung cancer (NSCLC). We performed this meta-analysis to evaluate the role of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in detecting occult mediastinal disease in NSCLC with no radiologic mediastinal involvement. The PubMed, Embase, and Cochrane libraries were searched for studies describing the role of EBUS-TBNA in lung cancer patients with radiologically negative mediastinum. The individual and pooled sensitivity, prevalence, negative predictive value (NPV), and diagnostic odds ratio (DOR) were calculated using the random effects model. Metaregression analysis, heterogeneity, and publication bias were also assessed. A total of 13 studies that met the inclusion criteria were included in the meta-analysis. The pooled effect size of the different diagnostic parameters were estimated as follows: prevalence, 12.8% (95% CI, 10.4%-15.7%); sensitivity, 49.5% (95% confidence interval [CI], 36.4%-62.6%); NPV, 93.0% (95% CI, 90.3%-95.0%); and log DOR, 5.069 (95% CI, 4.212-5.925). Significant heterogeneity was noticeable for the sensitivity, disease prevalence, and NPV, but not observed for log DOR. Publication bias was detected for sensitivity, NPV and log DOR but not for prevalence. Bivariate meta-regression analysis showed no significant association between the pooled calculated parameters and the type of anesthesia, imaging utilized to define negative mediastinum, rapid on-site test usage, and presence of bias by QUADAS-2 tool. Interestingly, we observed a greater sensitivity, NPV and log DOR for studies published prior to 2010, and for prospective multicenter studies. Among NSCLC patients with a radiologically normal mediastinum, the prevalence of mediastinal disease is 12.8% and the sensitivity of EBUS-TBNA is 49.5%. Despite the low sensitivity, the resulting NPV of 93.0% for EBUS-TBNA suggests that mediastinal metastasis is uncommon in such patients.
NASA Astrophysics Data System (ADS)
Garcia Franco, Noelia; Wiesmeier, Martin; Kiese, Ralf; Dannenmann, Michael; Wolf, Benjamin; Brandhuber, Robert; Beck, Robert; Kögel-Knabner, Ingrid
2016-04-01
In southern Germany, the alpine and pre-alpine grassland systems (> 1 Mio ha) provide an important economic value via fodder used for milk and meat production and grassland soils support environmental key functions (C and N storage, water retention, erosion control and biodiversity hot spot). In addition, these grassland soils constitute important regions for tourism and recreation. However, the different land use and management practices in this area introduce changes which are likely to accelerate due to climate change. The newly launched SUPSALPS project within the BonaRes Initiative of the German Ministry for Education and Research is focused on the development and evaluation of innovative grassland management strategies under climate change with an emphasis on soil functions, which are on the one hand environmental sustainable and on the other hand economically viable. Several field experiments of the project will be initialized in order to evaluate grassland soil functioning for a range of current and climate adapted management practices. A multi-factorial design combines ongoing and new plant-soil meso-/macrocosm and field studies at a multitude of existing long-term research sites along an elevation gradient in Bavaria. One of the specific objectives of the project is to improve our knowledge on the sensitivity of specific soil organic matter (SOM) fractions to climate change. Moreover, the project aims to determine the processes and mechanisms involved in the build-up and stabilization of C and N pools under different management practices. In order to derive sensitive SOM pools, a promising physical fractionation method was developed that enables the separation of five different SOM fractions by density, ultrasonication and sieving separation: fine particulate organic matter (fPOM), occluded particulate organic matter (oPOM>20μm and oPOM<20μm) and mineral associated organic matter (sand and coarse silt, > 20 μm; medium + fine silt and clay, < 20 μm). Methods to further characterize SOM (NMR, 13C and 15N stable isotopes, SEM, NanoSIMS) and the dynamics of plant and microbial communities will help us to fill knowledge gaps in the interaction of C and N dynamics in alpine and pre-alpine grassland soils and the rhizosphere under climate and land management changes.
A Hox regulatory network establishes motor neuron pool identity and target-muscle connectivity.
Dasen, Jeremy S; Tice, Bonnie C; Brenner-Morton, Susan; Jessell, Thomas M
2005-11-04
Spinal motor neurons acquire specialized "pool" identities that determine their ability to form selective connections with target muscles in the limb, but the molecular basis of this striking example of neuronal specificity has remained unclear. We show here that a Hox transcriptional regulatory network specifies motor neuron pool identity and connectivity. Two interdependent sets of Hox regulatory interactions operate within motor neurons, one assigning rostrocaudal motor pool position and a second directing motor pool diversity at a single segmental level. This Hox regulatory network directs the downstream transcriptional identity of motor neuron pools and defines the pattern of target-muscle connectivity.
Kamal, Faisal; Khan, Muhammad Ali; Khan, Zubair; Cholankeril, George; Hammad, Tariq A; Lee, Wade M; Ahmed, Aijaz; Waters, Bradford; Howden, Colin W; Nair, Satheesh; Satapathy, Sanjaya K
2017-10-01
Prophylactic antibiotics have been recommended in patients with a previous history of spontaneous bacterial peritonitis (SBP). Recently, there has been interest in the use of rifaximin for the prevention of SBP and hepatorenal syndrome (HRS). We conducted a meta-analysis to evaluate this association of rifaximin. We searched several databases from inception through 24 January 2017, to identify comparative studies evaluating the effect of rifaximin on the occurrence of SBP and HRS. We performed predetermined subgroup analyses based on the type of control group, design of the study, and type of prophylaxis. Pooled odds ratios (ORs) were calculated using a random effects model. We included 13 studies with 1703 patients in the meta-analysis of SBP prevention. Pooled OR [95% confidence interval (CI)] was 0.40 (95% CI: 0.22-0.73) (I=58%). On sensitivity analysis, adjusted OR was 0.29 (95% CI: 0.20-0.44) (I=0%). The results of the subgroup analysis based on type of control was as follows: in the quinolone group, pooled OR was 0.42 (95% CI: 0.14-1.25) (I=55%), and in the no antibiotic group, pooled OR was 0.40 (95% CI: 0.18-0.86) (I=64%). However, with sensitivity analysis, benefit of rifaximin was demonstrable; pooled ORs were 0.32 (95% CI: 0.17-0.63) (I=0%) and 0.28 (95% CI: 0.17-0.45) (I=0%) for the comparison with quinolones and no antibiotics, respectively. Pooled OR based on randomized controlled trials was 0.41 (95% CI: 0.22-0.75) (I=13%). For the prevention of HRS, the pooled OR was 0.25 (95% CI: 0.13-0.50) (I=0%). Rifaximin has a protective effect against the development of SBP in cirrhosis. However, the quality of the evidence as per the GRADE framework was very low. Rifaximin appeared effective for the prevention of HRS.
The impact of serum incubation time on IgM/IgG binding to porcine aortic endothelial cells.
Zhang, Zhongqiang; Gao, Bingsi; Zhao, Chengjiang; Long, Cassandra; Qi, Haizhi; Ezzelarab, Mohamed; Cooper, David Kc; Hara, Hidetaka
2017-07-01
The results of the assay for measuring anti-non-Gal antibodies (which affect pig xenograft survival) in recipients are important. Serum incubation time and concentration may be important factors in the extent of antibody binding to the graft. The aim of this in vitro study was to determine the optimal incubation time and serum concentration for measuring anti-non-Gal antibody binding to porcine aortic endothelial cells (pAECs). Pooled human, naive, and sensitized baboon sera were incubated with wild-type, α1,3-galactosyltransferase gene-knockout (GTKO), and GTKO/human CD55 pAECs. IgM/IgG binding to pAECs after varying serum incubation times (0.5, 1, 2, and 3 hour) and concentrations (5, 10, 20, and 40 μL) was determined by flow cytometry. An increase in incubation time from 30 minutes to 2 hour was associated with increases in anti-non-Gal IgM/IgG binding to GTKO and GTKO/hCD55 pAECs of pooled human, naive and sensitized baboon sera (P<.05). Pooled human serum showed a significant increase in anti-non-Gal IgM (1.5 times) and a minimal increase in anti-non-Gal IgG antibody binding. IgM/IgG binding of sensitized baboon serum to GTKO pAECs after 2-hour incubation was 1.5 times and 2 times greater than after 30-minutes incubation, respectively, whereas naïve baboon sera showed minimal (non-significant) increase in anti-non-Gal IgM/IgG antibody binding. With 2-hour incubation, increasing the serum concentration from 5 μL to 20 μL significantly increased antibody binding to non-Gal antigens in pooled human and sensitized baboon serum. With naïve baboon serum, only IgG was significantly increased. Increasing the serum incubation time contributed to improve the sensitivity of detecting anti-non-Gal antibodies, without affecting cell viability in vitro. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Health technology assessment of non-invasive interventions for weight loss and body shape in Iran
Nojomi, Marzieh; Moradi-Lakeh, Maziar; Velayati, Ashraf; Naghibzadeh-Tahami, Ahmad; Dadgostar, Haleh; Ghorabi, Gholamhossein; Moradi-Joo, Mohammad; Yaghoubi, Mohsen
2016-01-01
Background: The burden of obesity and diet-related chronic diseases is increasing in Iran, and prevention and treatment strategies are needed to address this problem. The aim of this study was to determine the outcome, cost, safety and cost-consequence of non-invasive weight loss interventions in Iran. Methods: We performed a systematic review to compare non-invasive interventions (cryolipolysis and radiofrequency/ ultrasonic cavitation) with semi-invasive (lipolysis) and invasive (liposuction). A sensitive electronic searching was done to find available interventional studies. Reduction of abdomen circumference (cm), reduction in fat layer thickness (%) and weight reduction (kg) were outcomes of efficacy. Meta-analysis with random models was used for pooling efficacy estimates among studies with the same follow-up duration. Average cost per intervention was estimated based on the capital, maintenance, staff, consumable and purchase costs. Results: Of 3,111 studies identified in our reviews, 13 studies assessed lipolysis, 10 cryolipolysis and 8 considered radiofrequency. Nine studies with the same follow-up duration in three different outcome group were included in meta-analysis. Radiofrequency showed an overall pooled estimate of 2.7 cm (95% CI; 2.3-3.1) of mean reduction in circumference of abdomen after intervention. Pooled estimate of reduction in fat layer thickness was 78% (95% CI; 73%-83%) after Lipolysis and a pooled estimate of weight loss was 3.01 kg (95% CI; 2.3-3.6) after lipousuction. The cost analysis revealed no significant differences between the costs of these interventions. Conclusion: The present study showed that non-invasive interventions appear to have better clinical efficacy, specifically in the body shape measurement, and less cost compared to invasive intervention (liposuction) PMID:27390717
Hunsaker, Joshua J H; Wyness, Sara P; Snow, Taylor M; Genzen, Jonathan R
2016-12-01
Refractometric methods to measure total protein (TP) in serum and plasma specimens have been replaced by automated biuret methods in virtually all routine clinical testing. A subset of laboratories, however, still report using refractometry to measure TP in conjunction with serum protein electrophoresis. The objective of this study was therefore to conduct a modern performance evaluation of a digital refractometer for TP measurement. Performance evaluation of a MISCO Palm Abbe™ digital refractometer was conducted through device familiarization, carryover, precision, accuracy, linearity, analytical sensitivity, analytical specificity, and reference interval verification. Comparison assays included a manual refractometer and an automated biuret assay. Carryover risk was eliminated using a demineralized distilled water (ddH 2 O) wash step. Precision studies demonstrated overall imprecision of 2.2% CV (low TP pool) and 0.5% CV (high TP pool). Accuracy studies demonstrated correlation to both manual refractometry and the biuret method. An overall positive bias (+5.0%) was observed versus the biuret method. On average, outlier specimens had an increased triglyceride concentration. Linearity was verified using mixed dilutions of: a) low and high concentration patient pools, or b) albumin-spiked ddH 2 O and high concentration patient pool. Decreased recovery was observed using ddH 2 O dilutions at low TP concentrations. Significant interference was detected at high concentrations of glucose (>267 mg/dL) and triglycerides (>580 mg/dL). Current laboratory reference intervals for TP were verified. Performance characteristics of this digital refractometer were validated in a clinical laboratory setting. Biuret method remains the preferred assay for TP measurement in routine clinical analyses.
Validation of a quantitative Eimeria spp. PCR for fresh droppings of broiler chickens.
Peek, H W; Ter Veen, C; Dijkman, R; Landman, W J M
2017-12-01
A quantitative Polymerase Chain Reaction (qPCR) for the seven chicken Eimeria spp. was modified and validated for direct use on fresh droppings. The analytical specificity of the qPCR on droppings was 100%. Its analytical sensitivity (non-sporulated oocysts/g droppings) was 41 for E. acervulina, ≤2900 for E. brunetti, 710 for E. praecox, 1500 for E. necatrix, 190 for E. tenella, 640 for E. maxima, and 1100 for E. mitis. Field validation of the qPCR was done using droppings with non-sporulated oocysts from 19 broiler flocks. To reduce the number of qPCR tests five grams of each pooled sample (consisting of ten fresh droppings) per time point were blended into one mixed sample. Comparison of the oocysts per gram (OPG)-counting method with the qPCR using pooled samples (n = 1180) yielded a Pearson's correlation coefficient of 0.78 (95% CI: 0.76-0.80) and a Pearson's correlation coefficient of 0.76 (95% CI: 0.70-0.81) using mixed samples (n = 236). Comparison of the average of the OPG-counts of the five pooled samples with the mixed sample per time point (n = 236) showed a Pearson's correlation coefficient (R) of 0.94 (95% CI: 0.92-0.95) for the OPG-counting method and 0.87 (95% CI: 0.84-0.90) for the qPCR. This indicates that mixed samples are practically equivalent to the mean of five pooled samples. The good correlation between the OPG-counting method and the qPCR was further confirmed by the visual agreement between the total oocyst/g shedding patterns measured with both techniques in the 19 broiler flocks using the mixed samples.
Rajpara, S M; Botello, A P; Townend, J; Ormerod, A D
2009-09-01
Dermoscopy improves diagnostic accuracy of the unaided eye for melanoma, and digital dermoscopy with artificial intelligence or computer diagnosis has also been shown useful for the diagnosis of melanoma. At present there is no clear evidence regarding the diagnostic accuracy of dermoscopy compared with artificial intelligence. To evaluate the diagnostic accuracy of dermoscopy and digital dermoscopy/artificial intelligence for melanoma diagnosis and to compare the diagnostic accuracy of the different dermoscopic algorithms with each other and with digital dermoscopy/artificial intelligence for the detection of melanoma. A literature search on dermoscopy and digital dermoscopy/artificial intelligence for melanoma diagnosis was performed using several databases. Titles and abstracts of the retrieved articles were screened using a literature evaluation form. A quality assessment form was developed to assess the quality of the included studies. Heterogeneity among the studies was assessed. Pooled data were analysed using meta-analytical methods and comparisons between different algorithms were performed. Of 765 articles retrieved, 30 studies were eligible for meta-analysis. Pooled sensitivity for artificial intelligence was slightly higher than for dermoscopy (91% vs. 88%; P = 0.076). Pooled specificity for dermoscopy was significantly better than artificial intelligence (86% vs. 79%; P < 0.001). Pooled diagnostic odds ratio was 51.5 for dermoscopy and 57.8 for artificial intelligence, which were not significantly different (P = 0.783). There were no significance differences in diagnostic odds ratio among the different dermoscopic diagnostic algorithms. Dermoscopy and artificial intelligence performed equally well for diagnosis of melanocytic skin lesions. There was no significant difference in the diagnostic performance of various dermoscopy algorithms. The three-point checklist, the seven-point checklist and Menzies score had better diagnostic odds ratios than the others; however, these results need to be confirmed by a large-scale high-quality population-based study.
Passiglia, Francesco; Rizzo, Sergio; Rolfo, Christian; Galvano, Antonio; Bronte, Enrico; Incorvaia, Lorena; Listi, Angela; Barraco, Nadia; Castiglia, Marta; Calo, Valentina; Bazan, Viviana; Russo, Antonio
2018-03-08
Recent studies evaluated the diagnostic accuracy of circulating tumor DNA (ctDNA) in the detection of epidermal growth factor receptor (EGFR) mutations from plasma of NSCLC patients, overall showing a high concordance as compared to standard tissue genotyping. However it is less clear if the location of metastatic site may influence the ability to identify EGFR mutations in plasma. This pooled analysis aims to evaluate the association between the metastatic site location and the sensitivity of ctDNA analysis in detecting EGFR mutations in NSCLC patients. Data from all published studies, evaluating the sensitivity of plasma-based EGFR-mutation testing, stratified by metastatic site location (extrathoracic (M1b) vs intrathoracic (M1a)) were collected by searching in PubMed, Cochrane Library, American Society of Clinical Oncology, and World Conference of Lung Cancer, meeting proceedings. Pooled Odds ratio (OR) and 95% confidence intervals (95% CIs) were calculated for the ctDNA analysis sensitivity, according to metastatic site location. A total of ten studies, with 1425 patients, were eligible. Pooled analysis showed that the sensitivity of ctDNA-based EGFR-mutation testing is significantly higher in patients with M1b vs M1a disease (OR: 5.09; 95% CIs: 2.93 - 8.84). A significant association was observed for both EGFR-activating (OR: 4.30, 95% CI: 2.35-7.88) and resistant T790M mutations (OR: 11.89, 95% CI: 1.45-97.22), regardless of the use of digital-PCR (OR: 5.85, 95% CI: 3.56-9.60) or non-digital PCR technologies (OR: 2.96, 95% CI: 2.24-3.91). These data suggest that the location of metastatic sites significantly influences the diagnostic accuracy of ctDNA analysis in detecting EGFR mutations in NSCLC patients. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Analytical Measurement of Discrete Hydrogen Sulfide Pools in Biological Specimens
Shen, Xinggui; Peter, Elvis A.; Bir, Shyamal; Wang, Rui; Kevil, Christopher G.
2015-01-01
Hydrogen sulfide (H2S) is a ubiquitous gaseous signaling molecule that plays a vital role in numerous cellular functions and has become the focus of many research endeavors including pharmaco-therapeutic manipulation. Amongst the challenges facing the field is the accurate measurement of biologically active H2S. We have recently reported that the typically used methylene blue method and its associated results are invalid and do not measure bonafide H2S. The complexity of analytical H2S measurement reflects the fact that hydrogen sulfide is a volatile gas and exists in the body in different forms, including a free form, an acid labile pool and as bound sulfane sulfur. Here we describe a new protocol to discretely measure specific H2S pools using the monobromobimane method coupled with RP-HPLC. This new protocol involves selective liberation, trapping and derivatization of H2S. Acid-labile H2S is released by incubating the sample in an acidic solution (pH 2.6) of 100 mM phosphate buffer with 0.1 mM DTPA, in an enclosed system to contain volatilized H2S. Volatilized H2S is then trapped in 100 mM Tris-HCl (pH 9.5, 0.1 mM DTPA) and then reacted with excess monobromobimane. In a separate aliquot, the contribution of bound sulfane sulfur pool was measured by incubating the sample with 1 mM TCEP (Tris(2-carboxyethyl)phosphine hydrochloride), a reducing agent to reduce disulfide bonds, in 100 mM phosphate buffer (pH 2.6, 0.1 mM DTPA), and H2S measurement performed in an analogous manner to the one described above. The acid labile pool was determined by subtracting the free hydrogen sulfide value from the value obtained by the acid liberation protocol. The bound sulfane sulfur pool was determined by subtracting the H2S measurement from the acid liberation protocol alone compared to that of TCEP plus acidic conditions. In summary, our new method protocol allows very sensitive and accurate measurement of the three primary biological pools of H2S including free, acid labile, and bound sulfane sulfur in various biological specimens. PMID:22561703
Single cell transcriptomic analysis of prostate cancer cells.
Welty, Christopher J; Coleman, Ilsa; Coleman, Roger; Lakely, Bryce; Xia, Jing; Chen, Shu; Gulati, Roman; Larson, Sandy R; Lange, Paul H; Montgomery, Bruce; Nelson, Peter S; Vessella, Robert L; Morrissey, Colm
2013-02-16
The ability to interrogate circulating tumor cells (CTC) and disseminated tumor cells (DTC) is restricted by the small number detected and isolated (typically <10). To determine if a commercially available technology could provide a transcriptomic profile of a single prostate cancer (PCa) cell, we clonally selected and cultured a single passage of cell cycle synchronized C4-2B PCa cells. Ten sets of single, 5-, or 10-cells were isolated using a micromanipulator under direct visualization with an inverted microscope. Additionally, two groups of 10 individual DTC, each isolated from bone marrow of 2 patients with metastatic PCa were obtained. RNA was amplified using the WT-Ovation™ One-Direct Amplification System. The amplified material was hybridized on a 44K Whole Human Gene Expression Microarray. A high stringency threshold, a mean Alexa Fluor® 3 signal intensity above 300, was used for gene detection. Relative expression levels were validated for select genes using real-time PCR (RT-qPCR). Using this approach, 22,410, 20,423, and 17,009 probes were positive on the arrays from 10-cell pools, 5-cell pools, and single-cells, respectively. The sensitivity and specificity of gene detection on the single-cell analyses were 0.739 and 0.972 respectively when compared to 10-cell pools, and 0.814 and 0.979 respectively when compared to 5-cell pools, demonstrating a low false positive rate. Among 10,000 randomly selected pairs of genes, the Pearson correlation coefficient was 0.875 between the single-cell and 5-cell pools and 0.783 between the single-cell and 10-cell pools. As expected, abundant transcripts in the 5- and 10-cell samples were detected by RT-qPCR in the single-cell isolates, while lower abundance messages were not. Using the same stringency, 16,039 probes were positive on the patient single-cell arrays. Cluster analysis showed that all 10 DTC grouped together within each patient. A transcriptomic profile can be reliably obtained from a single cell using commercially available technology. As expected, fewer amplified genes are detected from a single-cell sample than from pooled-cell samples, however this method can be used to reliably obtain a transcriptomic profile from DTC isolated from the bone marrow of patients with PCa.
Biomarkers of gluten sensitivity in patients with non-affective psychosis: a meta-analysis.
Lachance, Laura R; McKenzie, Kwame
2014-02-01
Dohan first proposed that there may be an association between gluten sensitivity and schizophrenia in the 1950s. Since then, this association has been measured using several different serum biomarkers of gluten sensitivity. At this point, it is unclear which serum biomarkers of gluten sensitivity are elevated in patients with schizophrenia. However, evidence suggests that the immune response in this group is different from the immune response to gluten found in patients with Celiac disease. A systematic literature review was performed to identify all original articles that measured biomarkers of gluten sensitivity in patients with schizophrenia and non-affective psychoses compared to a control group. Three databases were used: Ovid MEDLINE, Psych INFO, and Embase, dating back to 1946. Forward tracking and backward tracking were undertaken on retrieved papers. A meta-analysis was performed of specific biomarkers and reported according to MOOSE guidelines. 17 relevant original articles were identified, and 12 met criteria for the meta-analysis. Five biomarkers of gluten sensitivity were found to be significantly elevated in patients with non-affective psychoses compared to controls. The pooled odds ratio and 95% confidence intervals were Anti-Gliadin IgG OR=2.31 [1.16, 4.58], Anti-Gliadin IgA OR=2.57 [1.13, 5.82], Anti-TTG2 IgA OR=5.86 [2.88, 11.95], Anti-Gliadin (unspecified isotype) OR=7.68 [2.07, 28.42], and Anti-Wheat OR=2.74 [1.06, 7.08]. Four biomarkers for gluten sensitivity, Anti-EMA IgA, Anti-TTG2 IgG, Anti-DGP IgG, and Anti-Gluten were not found to be associated with schizophrenia. Not all serum biomarkers of gluten sensitivity are elevated in patients with schizophrenia. However, the specific immune response to gluten in this population differs from that found in patients with Celiac disease. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Mina, O.
2015-12-01
The presence of natural and synthetic estrogens in treated wastewater used for irrigation of agricultural fields poses a potential risk to surface water ecosystems. While a large number of recent studies have investigated the occurrence, fate, and transport of estrogens in the environment, the vast majority of these studies have focused on the fate of estrogens in streams and rivers. However, no studies have been conducted assessing the occurrence, persistence, and fate of estrogens in impacted sensitive aquatic ecosystems such as vernal pools. This is of particular importance because vernal pools serve as critical breeding habitat for amphibians, which are known to be sensitive to the presence of endocrine disrupting compounds. A spray irrigation system was implemented over 50 years ago at Penn State's "Living Filter" as an alternative to discharging treated wastewater to a high quality trout stream. This system introduces all of Penn State's treated wastewater onto approximately 250 ha of agricultural and forested land at a rate of ~5 cm/ha/week. More than a dozen vernal pools are impacted by this wastewater irrigation, with some ponds adjacent to irrigation laterals receiving direct inputs of the treated wastewater. The goal of this study was to assess the impact of these weekly irrigation activities on the occurrence, persistence, and fate of estrogens (17α- and 17β-estradiol, estrone, estriol, and ethinylestradiol) in 3 vernal pools during an 8-week field study. The spring 2015 study period coincided with wood frog breeding and metamorphosis. Irrigation wastewater was collected weekly and water samples near the sediment-water interface in each vernal pool were collected daily. Real-time monitoring stations continuously recorded the temperature, pH, redox potential, DO, EC, and water level at each pool. Nearly 100% of the daily samples (n>130) collected contained estrogens, and the concentrations were several times higher compared to the wastewater. Additionally, the data suggest transformation of estrone back to 17α- and 17β-estradiol potentially due to anaerobic conditions in the vernal pools. This unique field study suggests that more research is needed to quantify the potential impact of estrogenic activity on amphibians, particularly during the critical metamorphosis period.
Bidle, Kay D; Kwityn, Clifford J
2012-10-01
As part of their strategy to infect the globally important coccolithophore, Emiliania huxleyi (Lohmann) W.W. Hay & H.P. Mohler, Coccolithoviruses trigger and regulate the host's programmed cell death (PCD) machinery during lytic infection. The induction and recruitment of host metacaspases, specialized, ancestral death proteases that facilitate viral lysis, suggests they may be important subcellular determinants to infection. We examined the "basal" levels and patterns of caspase activity and metacaspase expression in exponentially growing resistant and sensitive E. huxleyi strains and linked them with susceptibility to E. huxleyi virus 1 (EhV1). Resistant E. huxleyi strains were consistently characterized by low caspase specific activity and a relatively simple metacaspase expression profile. In contrast, sensitive E. huxleyi strains had markedly elevated caspase specific activity and consistently expressed more diverse metacaspase proteins. Using pooled data sets from triplicate experiments, we observed statistically significant linear correlations between infectivity, caspase activity, and metacaspase expression, with each strain forming distinct clusters, within a gradient in viral susceptibility. At the same time, we observed positive correlations between the expression of a subset of metacaspase proteins and lower susceptibility, suggestive of potential protective roles. Our findings implicate the importance of subtle differences in the basal physiological regulation of the PCD machinery to viral resistance or sensitivity and cell fate. © 2012 Phycological Society of America.
Wimmer, B; Craig, B H; Pilkington, J G; Pemberton, J M
2004-04-01
Considerable effort has been put into detecting and identifying parasitic nematodes in live ruminants, but to date most studies are limited to a small group of nematodes and/or to experimentally infected sheep. In this study, a PCR-based assay using species-specific primer pairs, located in the second internal transcribed spacer ribosomal DNA, was developed to identify nine different species from six different families of parasitic nematodes in a wild, unmanaged and naturally infected population of sheep. Each primer pair was tested for its specificity and sensitivity and it exclusively amplified the species it was designed for and exhibited a high degree of sensitivity. The method was applied to eggs and cultured larvae to identify the parasitic nematodes present in a pooled faecal sample from several host individuals with unknown parasite burden. To test detection reliability, a faecal sample from an individual with known parasite burden (through post-mortem analysis) was also examined. All species present could be correctly identified by PCR, but detecting very low levels and/or early stages of infection proved to be difficult. The method was also tested for its applicability to high through-put screening of faecal samples.
Benz, C; Hollander, C; Keniry, M; James, T L; Mitchell, M
1987-01-01
Three compounds that share specific antimitochondrial properties are gossypol, rhodamine-123, and lonidamine. We compare the antiproliferative activities of these drugs against six human cell lines derived from breast (T47-D), pancreas (MiaPaCa, RWP-2), prostate (DU-145), colon (HCT-8), and cervix (HeLa) carcinomas. Tumor cells enriched in cathodal LDH isozymes (LDH4 and LDH5) are significantly more sensitive to gossypol and rhodamine-123. When compared for ability to inhibit growth of human marrow in soft agar, 10 microM gossypol shows little effect on colony formation whereas 10 microM rhodamine-123 completely prevents stem cell growth, suggesting that gossypol may have the most favorable therapeutic index. Within 24 h of drug administration, there is a relative increase in intracellular inorganic phosphate pools and a marked decline in soluble high-energy phosphates in sensitive tumor cells, as measured by 31P magnetic resonance spectroscopy. These studies suggest that specific antimitochondrial agents might be selectively administered on the basis of tumor LDH isozyme content and noninvasively monitored for antiproliferative activity by 31P spectroscopy. Images PMID:3805280
Hill, Stephen A; Booth, Ronald A; Santaguida, P Lina; Don-Wauchope, Andrew; Brown, Judy A; Oremus, Mark; Ali, Usman; Bustamam, Amy; Sohel, Nazmul; McKelvie, Robert; Balion, Cynthia; Raina, Parminder
2014-08-01
Our purpose was to determine the test performance characteristics of BNP and NT-proBNP in the diagnosis of heart failure for patients presenting to an emergency department or urgent care center. We searched Medline, Embase, AMED, Cochrane, Cochrane Database of Systematic Reviews, and CINAHL for English-language articles published between 1989 and June 2012. Studies were limited to those using FDA-approved assays. We examined test performance at three pre-specified cutpoints (manufacturers' suggested, researchers' optimal, and lowest) and considered the effect of age, gender, ethnicity and renal function. We used the QUADAS-2 tool to examine risk of bias and applicability, and the AHRQ Methods Guide to assess the strength of evidence. Seventy-six articles met our inclusion criteria, 37 examined BNP, 25 examined NT-proBNP, and 14 examined both. Pooled sensitivity and specificity for BNP at the three pre-specified cutpoints were 95, 91, and 95 % (sensitivity) and 55, 80, and 67 % (specificity), respectively. For NT-proBNP, sensitivity and specificity at the same cutpoints were 91, 90, and 96 % (sensitivity) and 67, 74, and 55 % (specificity). Both BNP and NT-proBNP perform well to rule out, but less well to rule in, the diagnosis of heart failure among persons presenting to emergency departments or urgent care centers. Both BNP and NT-proBNP levels are positively associated with age and negatively associated with renal function. However, the effect of these factors with respect to selecting optimal cutpoints is unclear. For BNP, 100 pg/mL appears to be a consensus cutpoint. No clear consensus has emerged for NT-proBNP, but the age-adjusted cutpoints of 450 pg/mL for <50 years, 900 pg/mL for 50-75 years and 1,800 pg/mL for >75 years appear promising and merit greater scrutiny and validation.
Moore, Abigail; Ashdown, Helen F; Shinkins, Bethany; Roberts, Nia W; Grant, Cameron C; Lasserson, Daniel S; Harnden, Anthony
2017-08-01
Pertussis (whooping cough) is a highly infective cause of cough that causes significant morbidity and mortality. Existing case definitions include paroxysmal cough, whooping, and posttussive vomiting, but diagnosis can be difficult. We determined the diagnostic accuracy of clinical characteristics of pertussis-associated cough. We systematically searched CINAHL, Embase, Medline, and SCI-EXPANDED/CPCI-S up to June 2016. Eligible studies compared clinical characteristics in those positive and negative for Bordetella pertussis infection, confirmed by laboratory investigations. Two authors independently completed screening, data extraction, and quality and bias assessments. For each characteristic, RevMan was used to produce descriptive forest plots. The bivariate meta-analysis method was used to generate pooled estimates of sensitivity and specificity. Of 1,969 identified papers, 53 were included. Forty-one clinical characteristics were assessed for diagnostic accuracy. In adult patients, paroxysmal cough and absence of fever have a high sensitivity (93.2% [CI, 83.2-97.4] and 81.8% [CI, 72.2-88.7], respectively) and low specificity (20.6% [CI, 14.7-28.1] and 18.8% [CI, 8.1-37.9]), whereas posttussive vomiting and whooping have low sensitivity (32.5% [CI, 24.5-41.6] and 29.8% [CI, 8.0-45.2]) and high specificity (77.7% [CI, 73.1-81.7] and 79.5% [CI, 69.4-86.9]). Posttussive vomiting in children is moderately sensitive (60.0% [CI, 40.3-77.0]) and specific (66.0% [CI, 52.5-77.3]). In adult patients, the presence of whooping or posttussive vomiting should rule in a possible diagnosis of pertussis, whereas the lack of a paroxysmal cough or the presence of fever should rule it out. In children, posttussive vomiting is much less helpful as a clinical diagnostic test. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Zhang, Yijing; Yao, Yi; Du, Weixing; Wu, Kai; Xu, Wenyue; Lin, Min; Tan, Huabing; Li, Jian
2017-07-01
In order to achieve better outcomes for treatment and in the prophylaxis of malaria, it is imperative to develop a sensitive, specific, and accurate assay for early diagnosis of Plasmodium falciparum infection, which is the major cause of malaria. In this study, we aimed to develop a loop-mediated isothermal amplification (LAMP) assay with P. falciparum unique genes for sensitive, specific, and accurate detection of P. falciparum infection. The unique genes of P. falciparum were randomly selected from PlasmoDB. The LAMP primers of the unique genes were designed using PrimerExplorer V4. LAMP assays with primers from unique genes of P. falciparum and conserved 18S rRNA gene were developed and their sensitivity was assessed. The specificity of the most sensitive LAMP assay was further examined using genomic DNA from Plasmodium vivax, Plasmodium yoelii and Toxoplasma gondii. Finally, the unique gene-based LAMP assay was validated using clinical samples of P. falciparum infection cases. A total of 31 sets of top-scored LAMP primers from nine unique genes were selected from the pools of designed primers. The LAMP assay with PF3D7_1253300-5 was the most sensitive with the detection limit 5 parasites/μl, and it displayed negative LAMP assay with the genomic DNA samples of P. vivax, P. yoelii, and T. gondii. The LAMP assay with PF3D7_0112300 (18S rRNA) was less sensitive with the detection limit 50 parasites/μl, and it displayed negative LAMP assay with the genomic DNA samples of P. yoelii and T. gondii, but displayed positive LAMP detection with P. vivax. The positive detection rate of the LAMP assay with PF3D7_1253300-5 was 90% (27/30), higher than that (80%, 24/30) of the positive rate of PF3D7_0112300 (18S rRNA) in examining clinical samples of P. falciparum infection cases. The LAMP assay with the primer set PF3D7_1253300-5 was more sensitive, specific, and accurate than those with PF3D7_0112300 (18S rRNA) in examining P. falciparum infection, and therefore it is a promising tool for diagnosis of P. falciparum infection.
A multiplex PCR for detection of six viruses in ducks.
Wang, Yongjuan; Zhu, Shanyuan; Hong, Weiming; Wang, Anping; Zuo, Weiyong
2017-10-01
In this study, six pairs of specific primers that can amplify DNA fragments of different sizes were designed and synthesized according to viral protein gene sequences published in GenBank. Then, a multiplex PCR method was established for rapid detection of duck hepatitis virus 1, duck plague virus, duck Tembusu virus, muscovy duck parvovirus, muscovy duck reovirus, and duck H9N2 avian influenza virus, and achieve simple and rapid detection of viral diseases in ducks. Single PCR was used to confirm primer specificity, and PCR conditions were optimized to construct a multiplex PCR system. Specificity and sensitivity assays were also developed. The multiplex PCR was used to detect duck embryos infected with mixed viruses and those with clinically suspected diseases to verify the feasibility of the multiplex PCR. Results show that the primers can specifically amplify target fragments, without any cross-amplification with other viruses. The multiplex PCR system can amplify six DNA fragments from the pooled viral genomes and specifically detect nucleic acids of the six duck susceptible viruses when the template amount is 10 2 copies/μl. In addition, the system can be used to detect viral nucleic acids in duck embryos infected with the six common viruses. The detection results for clinical samples are consistent with those detected by single PCR. Therefore, the established multiplex PCR method can perform specific, sensitive, and high-throughput detection of six duck-infecting viruses and can be applied to clinical identification and diagnosis of viral infection in ducks. Copyright © 2017. Published by Elsevier B.V.
2010-01-01
Miniaturization has evolved in the creation of a pocket-size imaging device which can be utilized as an ultrasound stethoscope. This study assessed the additional diagnostic power of pocket size device by both experts operators and trainees in comparison with physical examination and its appropriateness of use in comparison with standard echo machine in a non-cardiologic population. Three hundred four consecutive non cardiologic outpatients underwent a sequential assessment including physical examination, pocket size imaging device and standard Doppler-echo exam. Pocket size device was used by both expert operators and trainees (who received specific training before the beginning of the study). All the operators were requested to give only visual, qualitative insights on specific issues. All standard Doppler-echo exams were performed by expert operators. One hundred two pocket size device exams were performed by experts and two hundred two by trainees. The time duration of the pocket size device exam was 304 ± 117 sec. Diagnosis of cardiac abnormalities was made in 38.2% of cases by physical examination and in 69.7% of cases by physical examination + pocket size device (additional diagnostic power = 31.5%, p < 0.0001). The overall K between pocket size device and standard Doppler-echo was 0.67 in the pooled population (0.84 by experts and 0.58 by trainees). K was suboptimal for trainees in the eyeball evaluation of ejection fraction, left atrial dilation and right ventricular dilation. Overall sensitivity was 91% and specificity 76%. Sensitivity and specificity were lower in trainees than in experts. In conclusion, pocket size device showed a relevant additional diagnostic value in comparison with physical examination. Sensitivity and specificity were good in experts and suboptimal in trainees. Specificity was particularly influenced by the level of experience. Training programs are needed for pocket size device users. PMID:21110840
NASA Astrophysics Data System (ADS)
Bracho, R. G.; Schuur, E. A.; Pegoraro, E.; Crummer, K. G.; Natali, S.; Zhou, J.; Wu, L.; Luo, Y.; Tiedje, J. M.; Konstantinidis, K.
2013-12-01
Permafrost soils contain approximately1700 Pg of carbon (C), twice the amount of C in the atmosphere. Temperatures in higher latitudes are increasing, inducing permafrost thaw and subsequent microbial decomposition of previously frozen C. This process is one of the most likely positive feedbacks to climate change. Understanding the temperature sensitivity (Q10) and dynamics of SOM decomposition under warming is essential to predict the future state of the earth - climate system. Alaskan tundra soils were exposed to two winter warming (WW) seasons in the field, which warmed the soils by 4°C to 40 cm depth. Soils were obtained from three depths (0 - 15, 15 - 25 and 45 - 55 cm) and differed in initial amounts of labile and recalcitrant C. Soils were incubated in the lab under aerobic conditions, at 15 and 25°C over 365 days. Q10 was estimated at 14, 100 & 280 days of incubation (DOI); C fluxes were measured periodically and dynamics of SOM decomposition (C pool sizes and decay rates) were estimated by fitting a two pool C model to cumulative respired C (Ccum, mgC/ginitialC). After two WW seasons, initial C content tended to decrease through the soil profile and C:N ratio was significantly decreased in the top 15 cm. After one year of incubation, Ccum was twice as high at 25°C as at 15°C and significantly decreased with depth. No significant WW field treatment was detected, although Ccum tended to be lower in warmed soils. Labile C accounted for up to 5% of initial soil C content in the top 15 cm and decreased with depth. Soils exposed to WW had smaller labile C pools, and higher labile C decay rates in the top 25 cm. Q10 significantly decreased with time and depth as labile pool decreased, especially for WW. This decrease with time indicates a lower temperature sensitivity of the most recalcitrant C pool. The deepest WW soil layer, where warming was more pronounced, had significantly lower Q10 compared to control soils at the same depth. After two seasons, the warming treatment affected decomposition by reducing labile C pools and increasing its decay rates. Warming also reduced temperature sensitivity, showing acclimation of the most recalcitrant C pool in the tundra ecosystem.
NASA Technical Reports Server (NTRS)
Li, Xiaowen; Tao, Wei-Kuo; Khain, Alexander P.; Simpson, Joanne; Johnson, Daniel E.
2009-01-01
Part I of this paper compares two simulations, one using a bulk and the other a detailed bin microphysical scheme, of a long-lasting, continental mesoscale convective system with leading convection and trailing stratiform region. Diagnostic studies and sensitivity tests are carried out in Part II to explain the simulated contrasts in the spatial and temporal variations by the two microphysical schemes and to understand the interactions between cloud microphysics and storm dynamics. It is found that the fixed raindrop size distribution in the bulk scheme artificially enhances rain evaporation rate and produces a stronger near surface cool pool compared with the bin simulation. In the bulk simulation, cool pool circulation dominates the near-surface environmental wind shear in contrast to the near-balance between cool pool and wind shear in the bin simulation. This is the main reason for the contrasting quasi-steady states simulated in Part I. Sensitivity tests also show that large amounts of fast-falling hail produced in the original bulk scheme not only result in a narrow trailing stratiform region but also act to further exacerbate the strong cool pool simulated in the bulk parameterization. An empirical formula for a correction factor, r(q(sub r)) = 0.11q(sub r)(exp -1.27) + 0.98, is developed to correct the overestimation of rain evaporation in the bulk model, where r is the ratio of the rain evaporation rate between the bulk and bin simulations and q(sub r)(g per kilogram) is the rain mixing ratio. This formula offers a practical fix for the simple bulk scheme in rain evaporation parameterization.
Hyperforin changes the zinc-storage capacities of brain cells.
Gibon, Julien; Richaud, Pierre; Bouron, Alexandre
2011-12-01
In vitro and in vivo experiments were carried out to investigate the consequences on brain cells of a chronic treatment with hyperforin, a plant extract known to dissipate the mitochondrial membrane potential and to release Zn(2+) and Ca(2+) from these organelles. Dissociated cortical neurons were grown in a culture medium supplemented with 1 μM hyperforin. Live-cell imaging experiments with the fluorescent probes FluoZin-3 and Fluo-4 show that a 3 day-hyperforin treatment diminishes the size of the hyperforin-sensitive pools of Ca(2+) and Zn(2+) whereas it increases the size of the DTDP-sensitive pool of Zn(2+) without affecting the ionomycin-sensitive pool of Ca(2+). When assayed by quantitative PCR the levels of mRNA coding for metallothioneins (MTs) I, II and III were increased in cortical neurons after a 3 day-hyperforin treatment. This was prevented by the zinc chelator TPEN, indicating that the plant extract controls the expression of MTs in a zinc-dependent manner. Brains of adult mice who received a daily injection (i.p.) of hyperforin (4 mg/kg/day) for 4 weeks had a higher sulphur content than control animals. They also exhibited an enhanced expression of the genes coding for MTs. However, the long-term treatment did not affect the brain levels of calcium and zinc. Based on these results showing that hyperforin influences the size of the internal pools of Zn(2+), the expression of MTs and the brain cellular sulphur content, it is proposed that hyperforin changes the Zn-storage capacity of brain cells and interferes with their thiol status. Copyright © 2011 Elsevier Ltd. All rights reserved.
Liu, Sha; Zhang, Fuquan; Wang, Xijin; Shugart, Yin Yao; Zhao, Yingying; Li, Xinrong; Liu, Zhifen; Sun, Ning; Yang, Chunxia; Zhang, Kerang; Yue, Weihua; Yu, Xin; Xu, Yong
2017-11-10
There is an increasing interest in searching biomarkers for schizophrenia (SZ) diagnosis, which overcomes the drawbacks inherent with the subjective diagnostic methods. MicroRNA (miRNA) fingerprints have been explored for disease diagnosis. We performed a meta-analysis to examine miRNA diagnostic value for SZ and further validated the meta-analysis results. Using following terms: schizophrenia/SZ, microRNA/miRNA, diagnosis, sensitivity and specificity, we searched databases restricted to English language and reviewed all articles published from January 1990 to October 2016. All extracted data were statistically analyzed and the results were further validated with peripheral blood mononuclear cells (PBMNCs) isolated from patients and healthy controls using RT-qPCR and receiver operating characteristic (ROC) analysis. A total of 6 studies involving 330 patients and 202 healthy controls were included for meta-analysis. The pooled sensitivity, specificity and diagnostic odds ratio were 0.81 (95% CI: 0.75-0.86), 0.81 (95% CI: 0.72-0.88) and 18 (95% CI: 9-34), respectively; the positive and negative likelihood ratio was 4.3 and 0.24 respectively; the area under the curve in summary ROC was 0.87 (95% CI: 0.84-0.90). Validation revealed that miR-181b-5p, miR-21-5p, miR-195-5p, miR-137, miR-346 and miR-34a-5p in PBMNCs had high diagnostic sensitivity and specificity in the context of schizophrenia. In conclusion, blood-derived miRNAs might be promising biomarkers for SZ diagnosis.
Ganglion Cell Loss and Age-Related Visual Loss: A Cortical Pooling Analysis
SCHMIDT, LAURA A.; LY-SCHROEDER, EMILY; SWANSON, WILLIAM H.
2006-01-01
Purpose To evaluate the ability of the cortical pooling model to predict the effects of random, mild ganglion cell loss, we compared the predictions of the model with the age-related loss and variability in achromatic and chromatic contrast sensitivity. Methods The relative sensitivity to small (0.5°) and large (3.0°) stimuli was compared in older (mean = 67 years, n = 27) and younger (mean = 23 years, n = 32) adults. Contrast sensitivity for modulations along the luminance, equiluminant L-cone, and equiluminant S-cone axes was assessed at the fovea and at four peripheral locations (12°). Results When the stimuli were large, threshold measurements obtained from all participants were reliable and well within the range of modulations along the chromatic axes that could be produced by the phosphors of the CRT. For the large stimuli, neither long- nor short-term variability increased as a function of age. Increasing the size of the stimulus did not decrease the magnitude of the age-related losses when the stimulus was chromatic, and visual losses observed with large chromatic stimuli were not different from those obtained with small achromatic stimuli. Moreover, chromatic contrast sensitivity assessments identified significant visual losses in four individuals who were not identified by achromatic contrast sensitivity assessments and only missed identifying one individual with significant losses in achromatic contrast sensitivity. Conclusions The declines in achromatic and chromatic sensitivity as a function of age (0.4 – 0.7 dB per decade) were similar to those obtained in previous studies of achromatic and chromatic perimetry and are consistent with the loss of retinal ganglion cells reported in histologic studies. The results of this study are consistent with the predictions the cortical pooling model makes for both variability and contrast sensitivity. These findings emphasize that selective visual impairments do not necessarily reflect preferential damage to a single ganglion cell class and that it is important to include the influence of higher cortical processing when quantifying the relation between ganglion cells and visual function. PMID:16840870
NASA Astrophysics Data System (ADS)
Robertson, Andy; Schipanski, Meagan; Ma, Liwang; Ahuja, Lajpat; McNamara, Niall; Smith, Pete; Davies, Christian
2016-04-01
Changes in soil carbon (C) stocks have been studied in depth over the last two decades, as net greenhouse gas (GHG) sinks are highlighted to be a partial solution to the causes of climate change. However, the stability of this soil C is often overlooked when measuring these changes. Ultimately a net sequestration in soils is far less beneficial if labile C is replacing more stable forms. To date there is no accepted framework for measuring soil C stability, and as a result there is considerable uncertainty associated with the simulated impacts of land management and land use change when using process-based systems models. However, a recent effort to equate measurable soil C fractions to model pools has generated data that help to assess the impacts of land management, and can ultimately help to reduce the uncertainty of model predictions. Our research compiles this existing fractionation data along with site metadata to create a simplistic statistical model able to quantify the relative importance of different site-specific conditions. Data was mined from 23 published studies and combined with original data to generate a dataset of 100+ land use change sites across Europe. For sites to be included they required soil C fractions isolated using the Zimmermann et al. (2007) method and specific site metadata (mean annual precipitation, MAP; mean annual temperature, MAT; soil pH; land use; altitude). Of the sites, 75% were used to develop a generalized linear mixed model (GLMM) to create coefficients where site parameters can be used to predict influence on the measured soil fraction C stocks. The remaining 25% of sites were used to evaluate uncertainty and validate this empirical model. Further, four of the aforementioned sites were used to simulate soil C dynamics using the RothC, DayCent and RZWQM2 models. A sensitivity analysis (4096 model runs for each variable applying Latin hypercube random sampling techniques) was then used to observe whether these models place as much weight on the same site parameters as the GLMM. Sites were spread across an extensive geographic area and encompassed a wide range of conditions (2% to 44% clay content; 0.9° C to 18° C MAT; 300mm to 1400mm MAP). Topsoil (30 cm) C stocks also varied considerably (29.0 to 115.9 t/ha) but the proportion deemed stable (mean residence time >10 years) was relatively consistent (72 ± 2 %). The GLMM approach suggested that an interaction of soil pH and historic land use explained the largest amount of variation seen in stable fraction C stocks, closely followed by MAT and MAP interactions. For all three systems models, the stable soil C pools were most sensitive to climatic variables and land use. However, RZWQM2 did indicate that soil characteristics (texture, pH) also had an influence on stable C pool dynamics. References 1 - Zimmermann et al., 2007. Measured soil organic matter fractions can be related to pools in the RothC model. European Journal of Soil Science, 58:658-667.
Mechanisms of gender-related outcome differences after carotid endarterectomy.
den Hartog, Anne G; Algra, Ale; Moll, Frans L; de Borst, Gert J
2010-10-01
Large randomized trials have confirmed a difference in outcome after carotid endarterectomy (CEA) between men and women. In this review, we aimed to provide an overview of the gender-specific characteristics causing these perioperative and long-term outcome differences between men and women after CEA. A systematic search strategy with the synonyms of 'gender' and 'carotid endarterectomy' was conducted from PubMed and EMBASE databases. Only 11 relevant studies specifically discussing gender-specific related characteristics and their influence on outcome after CEA could be identified. Due to the limited number of included studies, pooling of findings was impossible, and results are presented in a descriptive manner. Each included study described only one possible gender-specific factor. Differences in carotid artery diameter, sex hormones, sensitivity for antiplatelet therapy, plaque morphology, occurrence of microembolic signals, and restenosis rate have all been suggested as gender-specific characteristics influencing outcome after CEA. Higher embolic potential in women and relatively stable female plaque morphology are the best-described factors influencing the difference in outcomes between men and women. However, the overall evidence for outcome differences by gender-specific characteristics in the literature is limited. Copyright © 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Soil Bulk Density by Soil Type, Land Use and Data Source: Putting the Error in SOC Estimates
NASA Astrophysics Data System (ADS)
Wills, S. A.; Rossi, A.; Loecke, T.; Ramcharan, A. M.; Roecker, S.; Mishra, U.; Waltman, S.; Nave, L. E.; Williams, C. O.; Beaudette, D.; Libohova, Z.; Vasilas, L.
2017-12-01
An important part of SOC stock and pool assessment is the assessment, estimation, and application of bulk density estimates. The concept of bulk density is relatively simple (the mass of soil in a given volume), the specifics Bulk density can be difficult to measure in soils due to logistical and methodological constraints. While many estimates of SOC pools use legacy data in their estimates, few concerted efforts have been made to assess the process used to convert laboratory carbon concentration measurements and bulk density collection into volumetrically based SOC estimates. The methodologies used are particularly sensitive in wetlands and organic soils with high amounts of carbon and very low bulk densities. We will present an analysis across four database measurements: NCSS - the National Cooperative Soil Survey Characterization dataset, RaCA - the Rapid Carbon Assessment sample dataset, NWCA - the National Wetland Condition Assessment, and ISCN - the International soil Carbon Network. The relationship between bulk density and soil organic carbon will be evaluated by dataset and land use/land cover information. Prediction methods (both regression and machine learning) will be compared and contrasted across datasets and available input information. The assessment and application of bulk density, including modeling, aggregation and error propagation will be evaluated. Finally, recommendations will be made about both the use of new data in soil survey products (such as SSURGO) and the use of that information as legacy data in SOC pool estimates.
Zhen, Chen; Xia, Zhang; Ya Jun, Zhou; Long, Li; Jian, Shuai; Gui Ju, Cai; Long, Li
2015-02-01
Accurate determination and detection of fever is essential in the appropriate treatment of pediatric population. It is widely known that improper definitions of fever can cause grave and dangerous consequences in medical procedures. Infrared tympanic thermometry seems a relatively new and popular alternative for traditional measurement in the diagnosis of pediatric fever. However, its accuracy in the diagnosis of fever remains a major concern. Systematic review and meta-analysis. Medline, Ovid, Elsevier, Google Scholar, and Cochrane library. Cross-sectional, prospective design. Two investigators independently assessed selected studies and extracted data. Disagreements were resolved by discussion with other reviewers. A total of 25 articles were included in our meta-analysis. The summary estimates revealed that the pooled sensitivity was 0.70 (95% confidence interval [CI] = 0.68-0.72), pooled specificity was 0.86 (95% CI = 0.85-0.88), and pooled diagnostic odds ratio was 47.3 (95% CI = 29.76-75.18), for the diagnosis of fever using infrared tympanic thermometry. Additionally, the area under the summary receiver operating characteristic curve was 0.94, and Q* value was 0.87. A total of 25 articles that encompassing 31 studies were analyzed. Based on our meta-analysis, accuracy of infrared tympanic thermometry in diagnosing fever is high. We can cautiously make conclusion that infrared tympanic thermometry should be widely used as fever of thermometer. © The Author(s) 2014.
Impact of ocean acidification and warming on the productivity of a rock pool community.
Legrand, Erwann; Riera, Pascal; Bohner, Olivier; Coudret, Jérôme; Schlicklin, Ferdinand; Derrien, Marie; Martin, Sophie
2018-05-01
This study examined experimentally the combined effect of ocean acidification and warming on the productivity of rock pool multi-specific assemblages, composed of coralline algae, fleshy algae, and grazers. Natural rock pool communities experience high environmental fluctuations. This may confer physiological advantage to rock pool communities when facing predicted acidification and warming. The effect of ocean acidification and warming have been assessed at both individual and assemblage level to examine the importance of species interactions in the response of assemblages. We hypothesized that rock pool assemblages have physiological advantage when facing predicted ocean acidification and warming. Species exhibited species-specific responses to increased temperature and pCO 2 . Increased temperature and pCO 2 have no effect on assemblage photosynthesis, which was mostly influenced by fleshy algal primary production. The response of coralline algae to ocean acidification and warming depended on the season, which evidenced the importance of physiological adaptations to their environment in their response to climate change. We suggest that rock pool assemblages are relatively robust to changes in temperature and pCO 2 , in terms of primary production. Copyright © 2018 Elsevier Ltd. All rights reserved.
Shah, D J; Lim, T-H
2012-01-01
Objectives We analysed pooled data from two clinical trials to assess the diagnostic accuracy and safety of meglumine gadoterate (Gd-DOTA)-enhanced MR angiography (MRA) relative to those of non-enhanced time-of-flight (TOF) MRA for non-coronary arterial disease. Both techniques were compared with X-ray angiography as the gold standard. Methods Patients were of both sexes, were aged at least 18 years and had suspected non-coronary arterial disease. Each patient was his/her own control and underwent TOF MRA followed by Gd-DOTA-enhanced MRA, and then X-ray angiography. MRA was performed at 1.5 T (USA study) or 3 T (Republic of Korea study). The primary criterion used to evaluate efficacy was the degree to which the MRA examination agreed with X-ray angiography in assessing non-coronary arterial lesions. The performance of Gd-DOTA over TOF was assessed using a one-sided paired t-test. We also evaluated the specificity, sensitivity, image quality, examination duration and clinical safety of both MRA procedures. Results In total, 192 patients were enrolled and received Gd-DOTA. In the intent-to-treat population (n=162), within-patient accuracy was significantly greater for Gd-DOTA than for TOF (85.8±19.8% agreement between Gd-DOTA and X-ray angiography compared with 78.3±24.9% agreement between TOF and X-ray angiography; p=0.0001). The sensitivity, specificity, image quality and examination duration were also better for Gd-DOTA than for TOF. There were no serious drug-related adverse events. Conclusion We conclude that Gd-DOTA-enhanced MRA is a safe and accurate procedure for detecting arterial stenosis at both 1.5 T and 3 T. PMID:22167518
Diagnostic accuracy of HbA1c in diabetes between Eastern and Western.
Yan, Shuang; Liu, Siying; Zhao, Yashuang; Zhang, Wencui; Sun, Xiaohui; Li, Jianing; Jiang, Fuli; Ju, Jiaming; Lang, Ning; Zhang, Yingqi; Zhou, Weiyu; Li, Qiang
2013-07-01
In 2010, the American Diabetes Association recommended the use of HbA1c as a diagnostic criterion for diabetes. However, HbA1c is not an accepted diagnostic tool for diabetes in Eastern Asia, because genetic differences compromise the standardization of the diagnostic cut-off point. This study evaluated differences in the use of HbA1c for diagnosing diabetes in Eastern and Western populations and investigated whether HbA1c cut-off point of ≥ 6.5% is diagnostic of diabetes in patients from Eastern Asia. Literature was obtained from MEDLINE, EMBASE and Cochrane databases. The pooled sensitivity and specificity of each HbA1c cut-off point were extracted and compared between Western and Eastern populations. Differences in the cut-off point for diagnosing diabetes in each region were compared by examining differences in the area under summary receiver operating characteristic (SROC) curves. Twelve publications from Eastern countries (n = 59,735) and 13 from Western countries (n = 22,954) were included in the analysis. Areas under SROC curves in the Eastern and Western groups were 0.9331 and 0.9120, respectively (P = 0.98). The cut-off point of the highest Youden index was 6.0%. At the HbA1c cut-off point of 6.5%, the pooled sensitivity and specificity were 58.7% and 98.4% for Eastern countries and 65.5% and 98.1% for Western countries, respectively. HbA1c exhibits the same diagnostic value for diabetes in Eastern and Western populations. In both populations, HbA1c levels > 6.0% identify the population at high risk of diabetes, and HbA1c > 6.5% is diagnostic of clinically established diabetes. © 2013 Stichting European Society for Clinical Investigation Journal Foundation. Published by John Wiley & Sons Ltd.
Diagnosing malignant melanoma in ambulatory care: a systematic review of clinical prediction rules.
Harrington, Emma; Clyne, Barbara; Wesseling, Nieneke; Sandhu, Harkiran; Armstrong, Laura; Bennett, Holly; Fahey, Tom
2017-03-06
Malignant melanoma has high morbidity and mortality rates. Early diagnosis improves prognosis. Clinical prediction rules (CPRs) can be used to stratify patients with symptoms of suspected malignant melanoma to improve early diagnosis. We conducted a systematic review of CPRs for melanoma diagnosis in ambulatory care. Systematic review. A comprehensive search of PubMed, EMBASE, PROSPERO, CINAHL, the Cochrane Library and SCOPUS was conducted in May 2015, using combinations of keywords and medical subject headings (MeSH) terms. Studies deriving and validating, validating or assessing the impact of a CPR for predicting melanoma diagnosis in ambulatory care were included. Data extraction and methodological quality assessment were guided by the CHARMS checklist. From 16 334 studies reviewed, 51 were included, validating the performance of 24 unique CPRs. Three impact analysis studies were identified. Five studies were set in primary care. The most commonly evaluated CPRs were the ABCD, more than one or uneven distribution of Colour, or a large (greater than 6 mm) Diameter (ABCD) dermoscopy rule (at a cut-point of >4.75; 8 studies; pooled sensitivity 0.85, 95% CI 0.73 to 0.93, specificity 0.72, 95% CI 0.65 to 0.78) and the 7-point dermoscopy checklist (at a cut-point of ≥1 recommending ruling in melanoma; 11 studies; pooled sensitivity 0.77, 95% CI 0.61 to 0.88, specificity 0.80, 95% CI 0.59 to 0.92). The methodological quality of studies varied. At their recommended cut-points, the ABCD dermoscopy rule is more useful for ruling out melanoma than the 7-point dermoscopy checklist. A focus on impact analysis will help translate melanoma risk prediction rules into useful tools for clinical practice. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Yavin, Daniel; Luu, Judy; James, Matthew T; Roberts, Derek J; Sutherland, Garnette R; Jette, Nathalie; Wiebe, Samuel
2014-09-01
Because clinical examination and imaging may be unreliable indicators of intracranial hypertension, intraocular pressure (IOP) measurement has been proposed as a noninvasive method of diagnosis. The authors conducted a systematic review and meta-analysis to determine the correlation between IOP and intracranial pressure (ICP) and the diagnostic accuracy of IOP measurement for detection of intracranial hypertension. The authors searched bibliographic databases (Ovid MEDLINE, Ovid EMBASE, and the Cochrane Central Register of Controlled Trials) from 1950 to March 2013, references of included studies, and conference abstracts for studies comparing IOP and invasive ICP measurement. Two independent reviewers screened abstracts, reviewed full-text articles, and extracted data. Correlation coefficients, sensitivity, specificity, and positive and negative likelihood ratios were calculated using DerSimonian and Laird methods and bivariate random effects models. The I(2) statistic was used as a measure of heterogeneity. Among 355 identified citations, 12 studies that enrolled 546 patients were included in the meta-analysis. The pooled correlation coefficient between IOP and ICP was 0.44 (95% CI 0.26-0.63, I(2) = 97.7%, p < 0.001). The summary sensitivity and specificity for IOP for diagnosing intracranial hypertension were 81% (95% CI 26%-98%, I(2) = 95.2%, p < 0.01) and 95% (95% CI 43%-100%, I(2) = 97.7%, p < 0.01), respectively. The summary positive and negative likelihood ratios were 14.8 (95% CI 0.5-417.7) and 0.2 (95% CI 0.02-1.7), respectively. When ICP and IOP measurements were taken within 1 hour of another, correlation between the measures improved. Although a modest aggregate correlation was found between IOP and ICP, the pooled diagnostic accuracy suggests that IOP measurement may be of clinical utility in the detection of intracranial hypertension. Given the significant heterogeneity between included studies, further investigation is required prior to the adoption of IOP in the evaluation of intracranial hypertension into routine practice.
Diagnostic value of circulating microRNAs for gastric cancer in Asian populations: a meta-analysis.
Liu, Lihua; Wang, Shan; Cao, Xiutang; Liu, Jianchao
2014-12-01
Gastric cancer (GC) accounts for one of the highest mortality worldwide and particularly in East Asia. Many studies have reported on the potential value of microRNAs (miRNAs) detection for diagnosing GC, but their results have proven inconclusive. The present meta-analysis was conducted to assess the diagnostic value of circulating miRNAs for GC diagnosis. A literature search was carried out in databases (PubMed, Embase, Web of Science, The Cochrane Library, and CNKI) and other sources using combinations of keywords relating to GC, miRNAs, and diagnosis. The values of sensitivity, specificity, positive likelihood ratios (PLR), negative likelihood ratios (NLR), and diagnostic odds ratio (DOR) reported in individual studies were pooled using random-effects models. Potential sources of heterogeneity were assessed with subgroup and meta-regression analyses. The summary receiver operating characteristic (SROC) curve and the area under the curve (AUC) were used to assess the diagnosis accuracy of miRNAs. This meta-analysis included 1,279 patients with GC and 954 healthy controls from 20 publications. The pooled sensitivity, specificity, PLR, NLR, DOR, and AUC were 0.78 (95 % CI: 0.73-0.81), 0.80 (95 % CI: 0.76-0.84), 4.0 (95 % CI: 3.1-6.0), 0.28 (95 % CI: 0.23-0.34), 14 (95 % CI: 10-21), and 0.86 (95 % CI: 0.83-0.89), respectively. Subgroup analyses showed that early stages (I and II) GC were more easily detected than later stages and that multiple miRNAs assays were more accurate than single miRNA assays. Our meta-analysis suggests that miRNAs have a high diagnostic value for GC, especially in its early stages (I and II). In addition, multiple miRNAs assays have a better diagnosis value than single miRNA assays. In conclusion, circulating miRNAs might be used as noninvasive biomarkers for the confirmation of GC detection in Asian populations.
Baradaran, Hediyeh; Delgado, Diana; Askin, Gulce; Christos, Paul; John Tsiouris, Apostolos; Gupta, Ajay
2017-01-01
Background. Distinction between tumor and treatment related changes is crucial for clinical management of patients with high-grade gliomas. Our purpose was to evaluate whether dynamic susceptibility contrast-enhanced (DSC) and dynamic contrast enhanced (DCE) perfusion-weighted imaging (PWI) metrics can effectively differentiate between recurrent tumor and posttreatment changes within the enhancing signal abnormality on conventional MRI. Methods. A comprehensive literature search was performed for studies evaluating PWI-based differentiation of recurrent tumor and posttreatment changes in patients with high-grade gliomas (World Health Organization grades III and IV). Only studies published in the “temozolomide era” beginning in 2005 were included. Summary estimates of diagnostic accuracy were obtained by using a random-effects model. Results. Of 1581 abstracts screened, 28 articles were included. The pooled sensitivities and specificities of each study's best performing parameter were 90% and 88% (95% CI: 0.85–0.94; 0.83–0.92) and 89% and 85% (95% CI: 0.78–0.96; 0.77–0.91) for DSC and DCE, respectively. The pooled sensitivities and specificities for detecting tumor recurrence using the 2 most commonly evaluated parameters, mean relative cerebral blood volume (rCBV) (threshold range, 0.9–2.15) and maximum rCBV (threshold range, 1.49–3.1), were 88% and 88% (95% CI: 0.81–0.94; 0.78–0.95) and 93% and 76% (95% CI: 0.86–0.98; 0.66–0.85), respectively. Conclusions. PWI-derived thresholds separating viable tumor from treatment changes demonstrate relatively good accuracy in individual studies. However, because of significant variability in optimal reported thresholds and other limitations in the existing body of literature, further investigation and standardization is needed before implementing any particular quantitative PWI strategy across institutions. PMID:27502247
Castle, Philip E.; Eaton, Barbara; Reid, Jennifer; Dockter, Janel
2015-01-01
Few studies have compared the cobas HPV test to the Aptima HPV assay (AHPV) and the Aptima HPV 16 18/45 genotype assay (AHPV GT) for high-risk human papillomavirus (hrHPV) detection, clinical performance in detecting cervical intraepithelial neoplasia grade 2 (CIN2) or more severe (CIN2+) diagnoses, and risk stratification by partial HPV genotyping. The cobas HPV test is a DNA test that separately and concurrently detects HPV16, HPV18, and a pool of 12 other hrHPV types. AHPV is an RNA test for a pool of 14 hrHPV genotypes, and AHPV GT is an RNA test run on AHPV-positive results to detect HPV16 separately from HPV18 and HPV45, which are detected together. In a population of patients (n = 988) referred for colposcopy because of a cervical Pap cytology result of atypical squamous cells of undetermined significance (ASC-US), a cervical scrape specimen was taken, placed into a ThinPrep Pap test vial containing PreservCyt liquid cytology medium, and tested in a blinded fashion with cobas and AHPV and with AHPV GT for AHPV-positive results. The final diagnoses were based on a consensus panel review of the biopsy specimen histology. AHPV and cobas were equally sensitive for CIN2+ diagnoses (89.4% each; P = 1.000), and AHPV was more specific than cobas (63.1% versus 59.3%; P ≤ 0.001). The percent total agreement, percent positive agreement, and kappa value were 90.9%, 81.1%, and 0.815, respectively. Risk stratification using partial HPV genotyping was similar for the two assays. AHPV and AHPV GT had similar sensitivity and risk stratification to cobas HPV, but they were more specific than cobas HPV. PMID:25653409
Chen, Yan; Xiao, Huangmeng; Zhou, Xieda; Huang, Xiaoyu; Li, Yanbing; Xiao, Haipeng; Cao, Xiaopei
2017-10-01
Various studies have validated plasma free metanephrines (MNs) as biomarkers for pheochromocytoma and paraganglioma (PPGL). This meta-analysis aimed to estimate the overall diagnostic accuracy of this biochemical test for PPGL. We searched the PubMed, the Cochrane Library, Web of Science, Embase, Scopus, OvidSP, and ProQuest Dissertations & Theses databases from January 1, 1995 to December 2, 2016 and selected studies written in English that assessed plasma free MNs in the diagnosis of PPGL. Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) was used to evaluate the quality of the included studies. We calculated pooled sensitivities, specificities, positive and negative likelihood ratios, diagnostic odds ratios (DORs) and areas under curve (AUCs) with their 95% confidence intervals (95% CIs). Heterogeneity was assessed by I 2 . To identify the source of heterogeneity, we evaluated the threshold effect and performed a meta-regression. Deeks' funnel plot was selected for investigating any potential publication bias. Although the combination of metanephrine (MN) and normetanephrine (NMN) carried lower specificity (0.94, 95% CI 0.90-0.97) than NMN (0.97, 95% CI 0.92-0.99), NMN was generally more accurate than individual tests, with the highest AUC (0.99, 95% CI 0.97-0.99), DOR (443.35, 95% CI 216.9-906.23), and pooled sensitivity (0.97, 95% CI 0.94-0.98) values. Threshold effect and meta-regression analyses showed that different cut-offs, blood sampling positions, study types and test methods contributed to heterogeneity. This meta-analysis suggested an effective value for combined plasma free MNs for the diagnosis of PPGL, but testing for MNs requires more standardization using tightly regulated studies. AUC = area under curve; CI = confidence interval; DOR = diagnostic odds ratio; EIA = enzyme immunoassay; LC-ECD = liquid chromatography-electrochemical detection; LC-MS/MS = liquid chromatography-tandem mass spectrometry; MN = metanephrine; NMN = normetaneprhine; PPGL = pheochromocytoma and paraganglioma; QUADAS-2 = Quality Assessment of Diagnostic Accuracy Studies 2.
Dai, Cong; Jiang, Min; Sun, Ming-Jun; Cao, Qin
2018-05-01
Fecal immunochemical test (FIT) is a promising marker for assessment of inflammatory bowel disease activity. However, the utility of FIT for predicting mucosal healing (MH) of ulcerative colitis (UC) patients has yet to be clearly demonstrated. The objective of our study was to perform a diagnostic test accuracy test meta-analysis evaluating the diagnostic accuracy of FIT in predicting MH of UC patients. We systematically searched the databases from inception to November 2017 that evaluated MH in UC. The methodological quality of each study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies checklist. The extracted data were pooled using a summary receiver operating characteristic curve model. Random-effects model was used to summarize the diagnostic odds ratio, sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Six studies comprising 625 UC patients were included in the meta-analysis. The pooled sensitivity and specificity values for predicting MH in UC were 0.77 (95% confidence interval [CI], 0.72-0.81) and 0.81 (95% CI, 0.76-0.85), respectively. The FIT level had a high rule-in value (positive likelihood ratio, 3.79; 95% CI, 2.85-5.03) and a moderate rule-out value (negative likelihood ratio, 0.26; 95% CI, 0.16-0.43) for predicting MH in UC. The results of the receiver operating characteristic curve analysis (area under the curve, 0.88; standard error of the mean, 0.02) and diagnostic odds ratio (18.08; 95% CI, 9.57-34.13) also revealed improved discrimination for identifying MH in UC with FIT concentration. Our meta-analysis has found that FIT is a simple, reliable non-invasive marker for predicting MH in UC patients. © 2018 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Diagnostic Value of Methylated Septin9 for Colorectal Cancer Screening: A Meta-Analysis
Yan, Shirong; Liu, Zijing; Yu, Shuang; Bao, Yixi
2016-01-01
Background Septin9 is a member of GTP-binding protein family, and is used as a predictive diagnostic index. However, it has not been widely adopted due to inconsistent results reported in the literature. The present study was performed to determine the diagnostic accuracy of methylated Septin9 (mSEPT9) for colorectal cancer (CRC) and to evaluate its utility in CRC screening. Material/Methods After reviewing relevant studies, accuracy measures (pooled sensitivity and specificity, positive/negative likelihood ratio [PLR/NLR], and diagnostic odds ratio [DOR]) were calculated for mSEPT9 in the diagnosis of CRC. Overall test performance was summarized using summary receiver operating characteristic curve analysis. Potential between-study heterogeneity was explored by use of a meta-regression model. We divided included studies into Epi proColon test and non-Epi proColon test subgroups. We compared the effects of mSEPT9 and fecal occult blood test (FOBT) for CRC screening. Results A total of 9870 subjects in 14 studies were recruited. Pooled sensitivity and specificity, PLR, NLR, DOR, and corresponding 95% confidence intervals (CI) of mSEPT9 for CRC diagnosis were 0.66 (95% CI: 0.64–0.69), 0.91 (95% CI: 0.90–0.91), 5.59 (95% CI: 4.03–7.74), 0.37 (95% CI: 0.29–0.48), and 16.79 (95% CI: 10.54–26.76), respectively. The area under the summary ROC curve (AUC) was 0.8563. The AUCs in the Epi proColon test and non-Epi proColon test for CRC diagnosis were 0.8709 and 0.7968, respectively. In head-to-head comparison, AUC of mSEPT9 and FOBT for CRC diagnosis were 0.7857 and 0.6571, respectively. Conclusions The present study demonstrates that mSEPT9 can be a good diagnostic biomarker complementary to FOBT as a screening tool for CRC. PMID:27665580
Diagnostic Value of Methylated Septin9 for Colorectal Cancer Screening: A Meta-Analysis.
Yan, Shirong; Liu, Zijing; Yu, Shuang; Bao, Yixi
2016-09-25
BACKGROUND Septin9 is a member of GTP-binding protein family, and is used as a predictive diagnostic index. However, it has not been widely adopted due to inconsistent results reported in the literature. The present study was performed to determine the diagnostic accuracy of methylated Septin9 (mSEPT9) for colorectal cancer (CRC) and to evaluate its utility in CRC screening. MATERIAL AND METHODS After reviewing relevant studies, accuracy measures (pooled sensitivity and specificity, positive/negative likelihood ratio [PLR/NLR], and diagnostic odds ratio [DOR]) were calculated for mSEPT9 in the diagnosis of CRC. Overall test performance was summarized using summary receiver operating characteristic curve analysis. Potential between-study heterogeneity was explored by use of a meta-regression model. We divided included studies into Epi proColon test and non-Epi proColon test subgroups. We compared the effects of mSEPT9 and fecal occult blood test (FOBT) for CRC screening. RESULTS A total of 9870 subjects in 14 studies were recruited. Pooled sensitivity and specificity, PLR, NLR, DOR, and corresponding 95% confidence intervals (CI) of mSEPT9 for CRC diagnosis were 0.66 (95% CI: 0.64-0.69), 0.91 (95% CI: 0.90-0.91), 5.59 (95% CI: 4.03-7.74), 0.37 (95% CI: 0.29-0.48), and 16.79 (95% CI: 10.54-26.76), respectively. The area under the summary ROC curve (AUC) was 0.8563. The AUCs in the Epi proColon test and non-Epi proColon test for CRC diagnosis were 0.8709 and 0.7968, respectively. In head-to-head comparison, AUC of mSEPT9 and FOBT for CRC diagnosis were 0.7857 and 0.6571, respectively. CONCLUSIONS The present study demonstrates that mSEPT9 can be a good diagnostic biomarker complementary to FOBT as a screening tool for CRC.
Peng, Qiliang; Zhang, Xueli; Min, Ming; Zou, Li; Shen, Peipei; Zhu, Yaqun
2017-07-04
This systematic analysis aimed to investigate the value of microRNA-21 (miR-21) in colorectal cancer for multiple purposes, including diagnosis and prognosis, as well as its predictive power in combination biomarkers. Fifty-seven eligible studies were included in our meta-analysis, including 25 studies for diagnostic meta-analysis and 32 for prognostic meta-analysis. For the diagnostic meta-analysis of miR-21 alone, the overall pooled results for sensitivity, specificity, and area under the curve (AUC) were 0.64 (95% CI: 0.53-0.74), 0.85 (0.79-0.90), and 0.85 (0.81-0.87), respectively. Circulating samples presented corresponding values of 0.72 (0.63-0.79), 0.84 (0.78-0.89), and 0.86 (0.83-0.89), respectively. For the diagnostic meta-analysis of miR-21-related combination biomarkers, the above three parameters were 0.79 (0.69-0.86), 0.79 (0.68-0.87), and 0.86 (0.83-0.89), respectively. Notably, subgroup analysis suggested that miRNA combination markers in circulation exhibited high predictive power, with sensitivity of 0.85 (0.70-0.93), specificity of 0.86 (0.77-0.92), and AUC of 0.92 (0.89-0.94). For the prognostic meta-analysis, patients with higher expression of miR-21 had significant shorter disease-free survival [DFS; pooled hazard ratio (HR): 1.60; 95% CI: 1.20-2.15] and overall survival (OS; 1.54; 1.27-1.86). The combined HR in tissues for DFS and OS were 1.76 (1.31-2.36) and 1.58 (1.30-1.93), respectively. Our comprehensive systematic review revealed that circulating miR-21 may be suitable as a diagnostic biomarker, while tissue miR-21 could be a prognostic marker for colorectal cancer. In addition, miRNA combination biomarkers may provide a new approach for clinical application.
Review: Diagnostic accuracy of PCR-based detection tests for Helicobacter Pylori in stool samples.
Khadangi, Fatemeh; Yassi, Maryam; Kerachian, Mohammad Amin
2017-12-01
Although different methods have been established to detect Helicobacter pylori (H. pylori) infection, identifying infected patients is an ongoing challenge. The aim of this meta-analysis was to provide pooled diagnostic accuracy measures for stool PCR test in the diagnosis of H. pylori infection. In this study, a systematic review and meta-analysis were carried out on various sources, including MEDLINE, Web of Sciences, and the Cochrane Library from April 1, 1999, to May 1, 2016. This meta-analysis adheres to the guidelines provided by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses report (PRISMA Statement). The clinical value of DNA stool PCR test was based on the pooled false positive, false negative, true positive, and true negative of different genes. Twenty-six of 328 studies identified met the eligibility criteria. Stool PCR test had a performance of 71% (95% CI: 68-73) sensitivity, 96% (95% CI: 94-97) specificity, and 65.6 (95% CI: 30.2-142.5) diagnostic odds ratio (DOR) in diagnosis of H. pylori. The DOR of genes which showed the highest performance of stool PCR tests was as follows: 23S rRNA 152.5 (95% CI: 55.5-418.9), 16S rRNA 67.9 (95%CI: 6.4-714.3), and glmM 68.1 (95%CI: 20.1-231.7). The sensitivity and specificity of stool PCR test are relatively in the same spectrum of other diagnostic methods for the detection of H. pylori infection. In descending order of significance, the most diagnostic candidate genes using PCR detection were 23S rRNA, 16S rRNA, and glmM. PCR for 23S rRNA gene which has the highest performance could be applicable to detect H. pylori infection. © 2017 John Wiley & Sons Ltd.
Consumers control diversity and functioning of a natural marine ecosystem.
Altieri, Andrew H; Trussell, Geoffrey C; Ewanchuk, Patrick J; Bernatchez, Genevieve; Bracken, Matthew E S
2009-01-01
Our understanding of the functional consequences of changes in biodiversity has been hampered by several limitations of previous work, including limited attention to trophic interactions, a focus on species richness rather than evenness, and the use of artificially assembled communities. In this study, we manipulated the density of an herbivorous snail in natural tide pools and allowed seaweed communities to assemble in an ecologically relevant and non-random manner. Seaweed species evenness and biomass-specific primary productivity (mg O(2) h(-1) g(-1)) were higher in tide pools with snails because snails preferentially consumed an otherwise dominant seaweed species that can reduce biomass-specific productivity rates of algal assemblages. Although snails reduced overall seaweed biomass in tide pools, they did not affect gross primary productivity at the scale of tide pools (mg O(2) h(-1) pool(-1) or mg O(2) h(-1) m(-2)) because of the enhanced biomass-specific productivity associated with grazer-mediated increases in algal evenness. Our results suggest that increased attention to trophic interactions, diversity measures other than richness, and particularly the effects of consumers on evenness and primary productivity, will improve our understanding of the relationship between diversity and ecosystem functioning and allow more effective links between experimental results and real-world changes in biodiversity.
Kahms, Martin; Klingauf, Jürgen
2018-01-01
Styryl dyes and genetically encoded pH-sensitive fluorescent proteins like pHluorin are well-established tools for the optical analysis of synaptic vesicle (SV) recycling at presynaptic boutons. Here, we describe the development of a new class of fluorescent probes based on pH-sensitive organic dyes covalently bound to lipids, providing a promising complementary assay to genetically encoded fluorescent probes. These new optical tracers allow a pure read out of membrane turnover during synaptic activity and visualization of multiple rounds of stimulation-dependent SV recycling without genetic perturbation. Measuring the incorporation efficacy of different dye-labeled lipids into budding SVs, we did not observe an enrichment of lipids with affinity for liquid ordered membrane domains. But most importantly, we found no evidence for a static segregation of SVs into recycling and resting pools. A small but significant fraction of SVs that is reluctant to release during a first round of evoked activity can be exocytosed during a second bout of stimulation, showing fast intermixing of SV pools within seconds. Furthermore, we found that SVs recycling spontaneously have a higher chance to re-occupy release sites than SVs recycling during high-frequency evoked activity. In summary, our data provide strong evidence for a highly dynamic and use-dependent control of the fractions of releasable or resting SVs. PMID:29456492
Pooling across cells to normalize single-cell RNA sequencing data with many zero counts.
Lun, Aaron T L; Bach, Karsten; Marioni, John C
2016-04-27
Normalization of single-cell RNA sequencing data is necessary to eliminate cell-specific biases prior to downstream analyses. However, this is not straightforward for noisy single-cell data where many counts are zero. We present a novel approach where expression values are summed across pools of cells, and the summed values are used for normalization. Pool-based size factors are then deconvolved to yield cell-based factors. Our deconvolution approach outperforms existing methods for accurate normalization of cell-specific biases in simulated data. Similar behavior is observed in real data, where deconvolution improves the relevance of results of downstream analyses.
IgE antibody to fish gelatin (type I collagen) in patients with fish allergy.
Sakaguchi, M; Toda, M; Ebihara, T; Irie, S; Hori, H; Imai, A; Yanagida, M; Miyazawa, H; Ohsuna, H; Ikezawa, Z; Inouye, S
2000-09-01
Most children with anaphylaxis to measles, mumps, and rubella vaccines had shown sensitivity to bovine gelatin that was included in the vaccines. Recently, it was found that bovine type I collagen, which is the main content in the gelatin, is a major allergen in bovine gelatin allergy. Fish meat and skin also contain type I collagen. The present study was designed to investigate IgE antibody to fish gelatin in children with fish allergy. Serum samples were taken from patients in 3 groups: (1) 10 patients with fish allergy and specific IgE to fish meat; (2) two patients with allergies to both fish meat and bovine gelatin and specific IgE to fish meat and bovine gelatin; and (3) 15 patients with atopic dermatitis and specific IgE to fish meat. Various fish gelatins (type I collagen) were prepared from fish skin. IgE antibody to fish gelatin was analyzed by using ELISA and immunoblotting. Of 10 patients with fish allergy, 3 had specific IgE to fish gelatin. Of two patients with fish allergy and bovine gelatin allergy, all had specific IgE to fish gelatin. Of 15 patients with atopic dermatitis and specific IgE to fish meat, 5 had specific IgE to fish gelatin. Furthermore, IgE from pooled serum of the patients reacted with both the alpha1 and alpha2 chains of fish type I collagen in immunoblots. There is cross-reactivity among gelatins from various fishes, but there is little cross-reactivity between fish and bovine gelatins. Some fish-sensitive patients possessed IgE antibody to fish gelatin. Fish gelatin (type I collagen) might be an allergen in subjects with fish allergy.
Le Dimna, M; Vrancken, R; Koenen, F; Bougeard, S; Mesplède, A; Hutet, E; Kuntz-Simon, G; Le Potier, M F
2008-01-01
Two real-time RT-PCR kits, developed by LSI (TaqVet CSF) and ADIAGENE (Adiavet CSF), obtained an agreement to be commercialised in France, subject to conditions, defined by the French Classical Swine Fever (CSF) National Reference Laboratory. The producers were asked to introduce an internal control to check the RNA extraction efficacy. The different criteria assessed were sensitivity, "pestivirus specificity", reproducibility and ease of handling, using 189 different samples. These samples were either CSFV inactivated strains or blood/serum/organs collected from CSFV experimentally infected pigs or naturally infected wild boars. The reproducibility of the assays was confirmed by the analysis of a batch-to-batch panel control that was used for inter-laboratory tests involving nine laboratories. The two kits were also tested for the use in mass diagnostics and the results proved the kits to be suited using pools of blood, serum and tonsils. Moreover, a field evaluation, carried out on spleen samples collected from the CSF surveillance of wild boars in an area known to be infected and from domestic pigs at a slaughterhouse, confirmed the high sensitivity and specificity of the two kits. This step-by-step evaluation procedure confirmed that the two commercial CSF real-time RT-PCR kits have a higher predictive value than the current diagnostic standard, Virus Isolation.
Thirumala, Parthasarathy D; Thiagarajan, Karthy; Gedela, Satyanarayana; Crammond, Donald J; Balzer, Jeffrey R
2016-03-01
The 30 day stroke rate following carotid endarterectomy (CEA) ranges between 2-6%. Such periprocedural strokes are associated with a three-fold increased risk of mortality. Our primary aim was to determine the diagnostic accuracy of electroencephalogram (EEG) in predicting perioperative strokes through meta-analysis of existing literature. An extensive search for relevant literature was undertaken using PubMed and Web of Science databases. Studies were included after screening using predetermined criteria. Data was extracted and analyzed. Summary sensitivity, specificity and diagnostic odds ratio were obtained. Subgroup analysis of studies using eight or more EEG channels was done. Perioperative stroke rate for the cohort of 8765 patients was 1.75%. Pooled sensitivity and specificity of EEG changes in predicting these strokes were 52% (95% confidence interval [CI], 43-61%) and 84% (95% CI, 81-86%) respectively. Summary estimates of the subgroup were similar. The diagnostic odds ratio was 5.85 (95% CI, 3.71-9.22). For the observed stroke rate, the positive likelihood ratio was 3.25 while the negative predictive value was 98.99%. According to these results, patients with perioperative strokes have six times greater odds of experiencing an intraoperative change in EEG during CEA. EEG monitoring was found to be highly specific in predicting perioperative strokes after CEA. Copyright © 2015 Elsevier Ltd. All rights reserved.
Adamberg, Kaarel; Adamberg, Signe; Ernits, Karin; Larionova, Anneli; Voor, Tiia; Jaagura, Madis; Visnapuu, Triinu; Alamäe, Tiina
2018-06-20
The aim of the study was to investigate the metabolism of non-digestible oligo- and polysaccharides by fecal microbiota, using isothermal microcalorimetry. The five tested substrates were raffinose, melibiose, a mixture of oligo- and polysaccharides produced from raffinose by levansucrase, levan synthesized from raffinose, and levan from timothy grass. Two inocula were comprised of pooled fecal samples from overweight or normal-weight children, from healthy adult volunteers and a pure culture of Bacteroides thetaiotaomicron as a reference bacterium for colon microbiota. The growth was analyzed based on the heat evolution curves, and the production of organic acids and gases. Taxonomic profiles of the microbiota were assessed by 16S rDNA sequencing. Raffinose and melibiose promoted the growth of bifidobacteria in all fecal pools. Several pool-specific substrate-related responses to raffinose and melibiose were revealed. Lactate-producing bacteria (Streptococcus and Enterococcus) became enriched in the pool of overweight children resulting in lactic acid as the major fermentation product on short saccharides. Acetic and butyric acids were prevalent at fermentation in the normal-weight pool coinciding with the enrichment of Catenibacterium. In the adult pool, the specific promotion of Bacteroides and Lachnospiraceae by levans was disclosed. In the fecal pool of normal-weight children, levans stimulated the growth of Senegalimassilia and Lachnoclostridium and this particular pool also showed the highest maximum heat production rate at levan fermentation. Levans and raffinose-derived oligosaccharides, but not raffinose and melibiose were completely fermented by a pure culture of Bacteroides thetaiotaomicron. The main conclusion from the study is that fecal microbiota of normal and overweight children have different compositions and they respond in specific manners to non-digestible oligo- and polysaccharides: raffinose, melibiose, raffinose-derived oligosaccharides and levans. The potential of the tested saccharides to support a healthy balance of colon microbiota requires further studies. Copyright © 2018. Published by Elsevier Ltd.
Hackett, Daniel A.; Baker, Michael K.
2016-01-01
The purpose of this study was to examine the effect of regular exercise training on insulin sensitivity in adults with type 2 diabetes mellitus (T2DM) using the pooled data available from randomised controlled trials. In addition, we sought to determine whether short-term periods of physical inactivity diminish the exercise-induced improvement in insulin sensitivity. Eligible trials included exercise interventions that involved ≥3 exercise sessions, and reported a dynamic measurement of insulin sensitivity. There was a significant pooled effect size (ES) for the effect of exercise on insulin sensitivity (ES, –0.588; 95% confidence interval [CI], –0.816 to –0.359; P<0.001). Of the 14 studies included for meta-analyses, nine studies reported the time of data collection from the last exercise bout. There was a significant improvement in insulin sensitivity in favour of exercise versus control between 48 and 72 hours after exercise (ES, –0.702; 95% CI, –1.392 to –0.012; P=0.046); and this persisted when insulin sensitivity was measured more than 72 hours after the last exercise session (ES, –0.890; 95% CI, –1.675 to –0.105; P=0.026). Regular exercise has a significant benefit on insulin sensitivity in adults with T2DM and this may persist beyond 72 hours after the last exercise session. PMID:27535644
Reserve Growth of Alberta Oil Pools
Verma, Mahendra K.; Cook, Troy
2008-01-01
This Open-File Report is based on a presentation delivered at the Fourth U.S. Geological Survey Workshop on Reserve Growth on March 10-11, 2008. It summarizes the results of a study of reserve growth of oil pools in Alberta Province, Canada. The study is part of a larger effort involving similar studies of fields in other important petroleum provinces around the world, with the overall objective of gaining a better understanding of reserve growth in fields with different geologic/reservoir parameters and different operating environments. The goals of the study were to: 1. Evaluate historical oil reserve data and assess reserve growth. 2. Develop reserve growth models/functions to help forecast hydrocarbon volumes. 3. Study reserve growth sensitivity to various parameters ? for example, pool size, porosity, oil gravity, and lithology. 4. Compare reserve growth in oil pools/fields of Alberta provinces with those from other large petroleum provinces.
Large-eddy simulations of a Salt Lake Valley cold-air pool
NASA Astrophysics Data System (ADS)
Crosman, Erik T.; Horel, John D.
2017-09-01
Persistent cold-air pools are often poorly forecast by mesoscale numerical weather prediction models, in part due to inadequate parameterization of planetary boundary-layer physics in stable atmospheric conditions, and also because of errors in the initialization and treatment of the model surface state. In this study, an improved numerical simulation of the 27-30 January 2011 cold-air pool in Utah's Great Salt Lake Basin is obtained using a large-eddy simulation with more realistic surface state characterization. Compared to a Weather Research and Forecasting model configuration run as a mesoscale model with a planetary boundary-layer scheme where turbulence is highly parameterized, the large-eddy simulation more accurately captured turbulent interactions between the stable boundary-layer and flow aloft. The simulations were also found to be sensitive to variations in the Great Salt Lake temperature and Salt Lake Valley snow cover, illustrating the importance of land surface state in modelling cold-air pools.
Predictive and concurrent validity of the Braden scale in long-term care: a meta-analysis.
Wilchesky, Machelle; Lungu, Ovidiu
2015-01-01
Pressure ulcer prevention is an important long-term care (LTC) quality indicator. While the Braden Scale is a recommended risk assessment tool, there is a paucity of information specifically pertaining to its validity within the LTC setting. We, therefore, undertook a systematic review and meta-analysis comparing Braden Scale predictive and concurrent validity within this context. We searched the Medline, EMBASE, PsychINFO and PubMed databases from 1985-2014 for studies containing the requisite information to analyze tool validity. Our initial search yielded 3,773 articles. Eleven datasets emanating from nine published studies describing 40,361 residents met all meta-analysis inclusion criteria and were analyzed using random effects models. Pooled sensitivity, specificity, positive predictive value (PPV), and negative predictive values were 86%, 38%, 28%, and 93%, respectively. Specificity was poorer in concurrent samples as compared with predictive samples (38% vs. 72%), while PPV was low in both sample types (25 and 37%). Though random effects model results showed that the Scale had good overall predictive ability [RR, 4.33; 95% CI, 3.28-5.72], none of the concurrent samples were found to have "optimal" sensitivity and specificity. In conclusion, the appropriateness of the Braden Scale in LTC is questionable given its low specificity and PPV, in particular in concurrent validity studies. Future studies should further explore the extent to which the apparent low validity of the Scale in LTC is due to the choice of cutoff point and/or preventive strategies implemented by LTC staff as a matter of course. © 2015 by the Wound Healing Society.
Effect of chloroquine on intestinal lipid metabolism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mansbach, C.M. 2d.; Arnold, A.; Garrett, M.
1987-11-01
Most studies that have quantitated recovery of infused lipid in the intestinal mucosa and mesenteric lymph have only been able to recapture 50-75%. One possibility is that the missing lipid enters a triacylglycerol (TG) storage pool in the enterocyte and is hydrolyzed by lysosomal lipase, and the free fatty acid released is transported by the portal vein. This postulate was tested by comparing glyceryl trioleate (TO)-infused rats pretreated with the lysosomotropic drug, chloroquine (6.3 mg.kg-1.h-1) with saline controls. Chloroquine increased mucosal TG from 94 +/- 6 to 128 +/- 8 mumol. Additionally, the specific activity of the mucosal TG relativemore » to the infused (/sup 3/H)TO was reduced in the treated rats. The mucosal TG increase was not due to impaired TG output, which remained the same as controls. We conclude that the TG in the acid lipase-sensitive pool derives most of its glyceride-glycerol from endogenous sources. Furthermore, the increment in mucosal TG caused by chloroquine is not enough to explain the majority of the acyl groups unaccounted for in the mucosa and lymph after a TG infusion. For these a direct passage of acyl groups through the enterocyte is postulated.« less
Sputum colour and bacteria in chronic bronchitis exacerbations: a pooled analysis.
Miravitlles, Marc; Kruesmann, Frank; Haverstock, Daniel; Perroncel, Renee; Choudhri, Shurjeel H; Arvis, Pierre
2012-06-01
We examined the correlation between sputum colour and the presence of potentially pathogenic bacteria in acute exacerbations of chronic bronchitis (AECBs). Data were pooled from six multicentre studies comparing moxifloxacin with other antimicrobials in patients with an AECB. Sputum was collected before antimicrobial therapy, and bacteria were identified by culture and Gram staining. Association between sputum colour and bacteria was determined using logistic regression. Of 4,089 sputum samples, a colour was reported in 4,003; 1,898 (46.4%) were culture-positive. Green or yellow sputum samples were most likely to yield bacteria (58.9% and 45.5% of samples, respectively), compared with 18% of clear and 39% of rust-coloured samples positive for potentially pathogenic microorganisms. Factors predicting a positive culture were sputum colour (the strongest predictor), sputum purulence, increased dyspnoea, male sex and absence of fever. Green or yellow versus white sputum colour was associated with a sensitivity of 94.7% and a specificity of 15% for the presence of bacteria. Sputum colour, particularly green and yellow, was a stronger predictor of potentially pathogenic bacteria than sputum purulence and increased dyspnoea in AECB patients. However, it does not necessarily predict the need for antibiotic treatment in all patients with AECB.
Juan, Li; Tong, Hong-li; Zhang, Pengjun; Guo, Guanghong; Wang, Zi; Wen, Xinyu; Dong, Zhennan; Tian, Ya-ping
2014-09-03
Small non-coding microRNAs (miRNAs) are involved in cancer development and progression, and serum profiles of cervical cancer patients may be useful for identifying novel miRNAs. We performed deep sequencing on serum pools of cervical cancer patients and healthy controls with 3 replicates and constructed a small RNA library. We used MIREAP to predict novel miRNAs and identified 2 putative novel miRNAs between serum pools of cervical cancer patients and healthy controls after filtering out pseudo-pre-miRNAs using Triplet-SVM analysis. The 2 putative novel miRNAs were validated by real time PCR and were significantly decreased in cervical cancer patients compared with healthy controls. One novel miRNA had an area under curve (AUC) of 0.921 (95% CI: 0.883, 0.959) with a sensitivity of 85.7% and a specificity of 88.2% when discriminating between cervical cancer patients and healthy controls. Our results suggest that characterizing serum profiles of cervical cancers by Solexa sequencing may be a good method for identifying novel miRNAs and that the validated novel miRNAs described here may be cervical cancer-associated biomarkers.
Wyatt, M C; Beswick, A D; Kunutsor, S K; Wilson, M J; Whitehouse, M R; Blom, A W
2016-06-15
Synovial biomarkers have recently been adopted as diagnostic tools for periprosthetic joint infection (PJI), but their utility is uncertain. The purpose of this systematic review and meta-analysis was to synthesize the evidence on the accuracy of the alpha-defensin immunoassay and leukocyte esterase colorimetric strip test for the diagnosis of PJI compared with the Musculoskeletal Infection Society diagnostic criteria. We performed a systematic review to identify diagnostic technique studies evaluating the accuracy of alpha-defensin or leukocyte esterase in the diagnosis of PJI. MEDLINE and Embase on Ovid, ACM, ADS, arXiv, CERN DS (Conseil Européen pour la Recherche Nucléaire Document Server), CrossRef DOI (Digital Object Identifier), DBLP (Digital Bibliography & Library Project), Espacenet, Google Scholar, Gutenberg, HighWire, IEEE Xplore (Institute of Electrical and Electronics Engineers digital library), INSPIRE, JSTOR (Journal Storage), OAlster (Open Archives Initiative Protocol for Metadata Harvesting), Open Content, Pubget, PubMed, and Web of Science were searched for appropriate studies indexed from inception until May 30, 2015, along with unpublished or gray literature. The classification of studies and data extraction were performed independently by 2 reviewers. Data extraction permitted meta-analysis of sensitivity and specificity with construction of receiver operating characteristic curves for each test. We included 11 eligible studies. The pooled diagnostic sensitivity and specificity of alpha-defensin (6 studies) for PJI were 1.00 (95% confidence interval [CI], 0.82 to 1.00) and 0.96 (95% CI, 0.89 to 0.99), respectively. The area under the curve (AUC) for alpha-defensin and PJI was 0.99 (95% CI, 0.98 to 1.00). The pooled diagnostic sensitivity and specificity of leukocyte esterase (5 studies) for PJI were 0.81 (95% CI, 0.49 to 0.95) and 0.97 (95% CI, 0.82 to 0.99), respectively. The AUC for leukocyte esterase and PJI was 0.97 (95% CI, 0.95 to 0.98). There was substantial heterogeneity among studies for both diagnostic tests. The diagnostic accuracy for PJI was high for both tests. Given the limited number of studies and the large cost difference between the tests, more independent research on these tests is warranted. Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
Holec-Gąsior, Lucyna; Ferra, Bartłomiej; Hiszczyńska-Sawicka, Elżbieta; Kur, Józef
2014-12-15
Toxoplasmosis, caused by Toxoplasma gondii, is the major parasitic disease affecting sheep. Infection not only results in significant reproductive losses in these animals, but has public health implications since consumption of infected meat can facilitate zoonotic transmission. Although several serological tests are currently used for diagnosis of ovine toxoplasmosis, production of reliable reagents is a constraint and therefore there is a need to develop new diagnostic tools. In this paper, we assess for the first time, the preliminary diagnostic utility of 19 T. gondii recombinant antigens (GRA1, GRA2ex2, GRA4, GRA5, GRA6, GRA9, SAG1, SAG4, BSR4, P22, ROP1, P36, MIC1ex2, MIC1ex34, MIC3, MAG1, BAG1, LDH1, and LDH2) in immunoglobulin G (IgG) enzyme-linked immunosorbent assays (IgG ELISAs). Following an initial evaluation, eight recombinant antigens (GRA1, GRA9, SAG1, SAG4, P22, MIC1ex2, MIC3, ROP1) were chosen for subsequent testing and comparison against the native Toxoplasma lysate antigen (TLA) in IgG ELISAs using 88 sera from naturally infected sheep and 20 sera from healthy animals. The reactivity of these antigens was variable with the best results for GRA1, P22, ROP1 and TLA. High sensitivity and specificity (100%) was noted for GRA1, ROP1 and TLA; P22 showed a slightly lower sensitivity (98.9%) but the same high specificity (100%). Four different combinations of these antigens (M1: GRA1+ROP1; M2: GRA1+P22; M3: P22+ROP1; M4: GRA1+P22+ROP1) were tested against the same pool of ovine sera; all IgG-positive serum samples were detected by all of the mixtures. However, the most effective for diagnosis of toxoplasmosis in sheep, based on the highest absorbance values, was the mixture M4 containing three proteins. High sensitivity and specificity (100%) was observed from tests containing either M4 or TLA antigens with a new pool of sera (93 seropositive and 35 seronegative). Thus, the present study shows that a cocktail of GRA1+P22+ROP1 recombinant proteins can be used to diagnose T. gondii infection in sheep, and consequently will assist in epidemiological studies. Copyright © 2014 Elsevier B.V. All rights reserved.
Cusack, Daniela F; Silver, Whendee L; Torn, Margaret S; Burton, Sarah D; Firestone, Mary K
2011-03-01
Microbial communities and their associated enzyme activities affect the amount and chemical quality of carbon (C) in soils. Increasing nitrogen (N) deposition, particularly in N-rich tropical forests, is likely to change the composition and behavior of microbial communities and feed back on ecosystem structure and function. This study presents a novel assessment of mechanistic links between microbial responses to N deposition and shifts in soil organic matter (SOM) quality and quantity. We used phospholipid fatty acid (PLFA) analysis and microbial enzyme assays in soils to assess microbial community responses to long-term N additions in two distinct tropical rain forests. We used soil density fractionation and 13C nuclear magnetic resonance (NMR) spectroscopy to measure related changes in SOM pool sizes and chemical quality. Microbial biomass increased in response to N fertilization in both tropical forests and corresponded to declines in pools of low-density SOM. The chemical quality of this soil C pool reflected ecosystem-specific changes in microbial community composition. In the lower-elevation forest, there was an increase in gram-negative bacteria PLFA biomass, and there were significant losses of labile C chemical groups (O-alkyls). In contrast, the upper-elevation tropical forest had an increase in fungal PLFAs with N additions and declines in C groups associated with increased soil C storage (alkyls). The dynamics of microbial enzymatic activities with N addition provided a functional link between changes in microbial community structure and SOM chemistry. Ecosystem-specific changes in microbial community composition are likely to have far-reaching effects on soil carbon storage and cycling. This study indicates that microbial communities in N-rich tropical forests can be sensitive to added N, but we can expect significant variability in how ecosystem structure and function respond to N deposition among tropical forest types.
A Comparative Analysis of the ADOS-G and ADOS-2 Algorithms: Preliminary Findings.
Dorlack, Taylor P; Myers, Orrin B; Kodituwakku, Piyadasa W
2018-06-01
The Autism Diagnostic Observation Schedule (ADOS) is a widely utilized observational assessment tool for diagnosis of autism spectrum disorders. The original ADOS was succeeded by the ADOS-G with noted improvements. More recently, the ADOS-2 was introduced to further increase its diagnostic accuracy. Studies examining the validity of the ADOS have produced mixed findings, and pooled relationship trends between the algorithm versions are yet to be analyzed. The current review seeks to compare the relative merits of the ADOS-G and ADOS-2 algorithms, Modules 1-3. Eight studies met inclusion criteria for the review, and six were selected for paired comparisons of the sensitivity and specificity of the ADOS. Results indicate several contradictory findings, underscoring the importance of further study.
A new Method for Determining the Interplanetary Current-Sheet Local Orientation
NASA Astrophysics Data System (ADS)
Blanco, J. J.; Rodríguez-pacheco, J.; Sequeiros, J.
2003-03-01
In this work we have developed a new method for determining the interplanetary current sheet local parameters. The method, called `HYTARO' (from Hyperbolic Tangent Rotation), is based on a modified Harris magnetic field. This method has been applied to a pool of 57 events, all of them recorded during solar minimum conditions. The model performance has been tested by comparing both, its outputs and noise response, with these of the `classic MVM' (from Minimum Variance Method). The results suggest that, despite the fact that in many cases they behave in a similar way, there are specific crossing conditions that produce an erroneous MVM response. Moreover, our method shows a lower noise level sensitivity than that of MVM.
Substrate recognition by ribonucleoprotein ribonuclease MRP
Esakova, Olga; Perederina, Anna; Quan, Chao; Berezin, Igor; Krasilnikov, Andrey S.
2011-01-01
The ribonucleoprotein complex ribonuclease (RNase) MRP is a site-specific endoribonuclease essential for the survival of the eukaryotic cell. RNase MRP closely resembles RNase P (a universal endoribonuclease responsible for the maturation of the 5′ ends of tRNA) but recognizes distinct substrates including pre-rRNA and mRNA. Here we report the results of an in vitro selection of Saccharomyces cerevisiae RNase MRP substrates starting from a pool of random sequences. The results indicate that RNase MRP cleaves single-stranded RNA and is sensitive to sequences in the immediate vicinity of the cleavage site requiring a cytosine at the position +4 relative to the cleavage site. Structural implications of the differences in substrate recognition by RNases P and MRP are discussed. PMID:21173200
Substrate recognition by ribonucleoprotein ribonuclease MRP.
Esakova, Olga; Perederina, Anna; Quan, Chao; Berezin, Igor; Krasilnikov, Andrey S
2011-02-01
The ribonucleoprotein complex ribonuclease (RNase) MRP is a site-specific endoribonuclease essential for the survival of the eukaryotic cell. RNase MRP closely resembles RNase P (a universal endoribonuclease responsible for the maturation of the 5' ends of tRNA) but recognizes distinct substrates including pre-rRNA and mRNA. Here we report the results of an in vitro selection of Saccharomyces cerevisiae RNase MRP substrates starting from a pool of random sequences. The results indicate that RNase MRP cleaves single-stranded RNA and is sensitive to sequences in the immediate vicinity of the cleavage site requiring a cytosine at the position +4 relative to the cleavage site. Structural implications of the differences in substrate recognition by RNases P and MRP are discussed.
2010-04-01
Prescribed by ANSI Std Z39-18 senescence and thereby prevent radiation- induced stem cell pool exhaustion. Our laboratory has shown that the isofla- vone...genistein transiently arrests the LT-HSC in the G0/ G1 phases of the cell cycle and reduces radiation- induced genotoxicity, senescence, and stem cell ...captopril- induced radiation protection correlated with tran- sient quiescence (increased G0) of the ST-HSC population and prevention of stem cell pool
Frequency of progression from acute to chronic pancreatitis and risk factors: a meta-analysis.
Sankaran, Sharanya J; Xiao, Amy Y; Wu, Landy M; Windsor, John A; Forsmark, Christopher E; Petrov, Maxim S
2015-11-01
Acute pancreatitis (AP) and chronic pancreatitis (CP) traditionally have been thought to be distinct diseases, but there is evidence that AP can progress to CP. Little is known about the mechanisms of pancreatitis progression. We performed a meta-analysis to quantify the frequency of transition of AP to CP and identify risk factors for progression. We searched PubMed, Scopus, and Embase for studies of patients with AP who developed CP, published from 1966 through November 2014. Pooled prevalence and 95% confidence intervals (CIs) were calculated for these outcomes, and sensitivity, subgroup, and meta-regression analyses were conducted. We analyzed 14 studies, which included a total of 8492 patients. The pooled prevalence of recurrent AP was 22% (95% CI, 18%-26%), and the pooled prevalence of CP was 10% (95% CI, 6%-15%). Sensitivity analyses yielded a pooled prevalence of CP of 10% (95% CI, 4%-19%) and 36% (95% CI, 20%-53%) in patients after the first occurrence and recurrent AP, respectively. Subgroup analyses found alcohol use and smoking to be the largest risk factors for the development of CP, with pooled prevalence values of 65% (95% CI, 48%-56%) and 61% (95% CI, 47%-73%), respectively. Meta-regression analysis found that men were more likely than women to transition from AP to CP. Ten percent of patients with a first episode of AP and 36% of patients with recurrent AP develop CP; the risk is higher among smokers, alcoholics, and men. Prospective clinical studies are needed to study pancreatitis progression. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.
Effect of the pool depth on drop impact splashing
NASA Astrophysics Data System (ADS)
Chizari, Hossain; Thoraval, Marie-Jean
2017-11-01
We investigate the effect of the pool depth on the splashing dynamics of drop impact. The splashing of a single drop impacting into a deep pool or on wet surface has been investigated for many years both numerically and experimentally. However, recent results have demonstrated the importance of the vorticity produced during the impact on the splashing behavior. More specifically, the shedding of a vortex ring inside the liquid during the impact can separate the splash jet into several parts. The shedding of the vorticity can be influenced by the proximity of the bottom of the pool, if the pool depth is small enough. We study here how the pool depth can affect the vorticity shedding and the resulting splashing jets. We perform axisymmetric numerical simulations of the impacts with the open sources codes Gerris and Basilisk, and systematically vary the impact conditions, focusing on the effect of pool depth in the splashing regimes.
Limonene hydroperoxide analogues show specific patch test reactions.
Christensson, Johanna Bråred; Hellsén, Staffan; Börje, Anna; Karlberg, Ann-Therese
2014-05-01
The fragrance terpene R-limonene is a very weak sensitizer, but forms allergenic oxidation products upon contact with air. The primary oxidation products of oxidized limonene, the hydroperoxides, have an important impact on the sensitizing potency of the oxidation mixture. One analogue, limonene-1-hydroperoxide, was experimentally shown to be a significantly more potent sensitizer than limonene-2-hydroperoxide in the local lymph node assay with non-pooled lymph nodes. To investigate the pattern of reactivity among consecutive dermatitis patients to two structurally closely related limonene hydroperoxides, limonene-1-hydroperoxide and limonene-2-hydroperoxide. Limonene-1-hydroperoxide, limonene-2-hydroperoxide, at 0.5% in petrolatum, and oxidized limonene 3.0% pet. were tested in 763 consecutive dermatitis patients. Of the tested materials, limonene-1-hydroperoxide gave most reactions, with 2.4% of the patients showing positive patch test reactions. Limonene-2-hydroperoxide and oxidized R-limonene gave 1.7% and 1.2% positive patch test reactions, respectively. Concomitant positive patch test reactions to other fragrance markers in the baseline series were frequently noted. The results are in accordance with the experimental studies, as limonene-1-hydroperoxide gave more positive patch test reactions in the tested patients than limonene-2-hydroperoxide. Furthermore, the results support the specificity of the allergenic activity of the limonene hydroperoxide analogues and the importance of oxidized limonene as a cause of contact allergy. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Gao, Fei; Jiang, Hang; Cui, Xiao-yang
2015-07-01
Soil samples collected from virgin Korean pine forest and broad-leaved secondary forest in Xiaoxing'an Mountains, Northeast China were incubated in laboratory at different temperatures (8, 18 and 28 °C) for 160 days, and the data from the incubation experiment were fitted to a three-compartment, first-order kinetic model which separated soil organic carbon (SOC) into active, slow, and resistant carbon pools. Results showed that the soil organic carbon mineralization rates and the cumulative amount of C mineralized (all based on per unit of dry soil mass) of the broad-leaved secondary forest were both higher than that of the virgin Korean pine forest, whereas the mineralized C accounted for a relatively smaller part of SOC in the broad-leaved secondary forest soil. Soil active and slow carbon pools decreased with soil depth, while their proportions in SOC increased. Soil resistant carbon pool and its contribution to SOC were both greater in the broad-leaved secondary forest soil than in the virgin Korean pine forest soil, suggesting that the broad-leaved secondary forest soil organic carbon was relatively more stable. The mean retention time (MRT) of soil active carbon pool ranged from 9 to 24 d, decreasing with soil depth; while the MRT of slow carbon pool varied between 7 and 24 a, increasing with soil depth. Soil active carbon pool and its proportion in SOC increased linearly with incubation temperature, and consequently, decreased the slow carbon pool. Virgin Korean pine forest soils exhibited a higher increasing rate of active carbon pool along temperature gradient than the broad-leaved secondary forest soils, indicating that the organic carbon pool of virgin Korean pine forest soil was relatively more sensitive to temperature change.
Just like the lottery? Player behaviour and anomalies in the market for football pools.
Forrest, David; Pérez, Levi
2015-06-01
Football pools were an antecedent to lotto in providing a long-odds, high-prize gambling opportunity for a mass market in Europe. Even after lotto has become well established, pools games continue to occupy a significant niche in the gaming market in several jurisdictions, most notably Spain. This paper employs 23 years of sales data from the national pools game in Spain to investigate similarities between the behaviour of lotto players and pools players. It observes similar phenomena as have been noted in lotto sales studies, including strong sensitivity of sales to the size of jackpot on offer, significant habit effects, a halo effect whereby there is some short-term persistence in increased sales whenever a high jackpot is offered (even after jackpot size has returned to normal), and a tendency to jackpot fatigue (over time, the size of the jackpot has to be increased to more than before to stimulate the same increase in sales). Notwithstanding that the football pools are marketed as based on knowledge and understanding of sport whereas lotto is a pure numbers game, modelling sales of the pools therefore yields findings very similar to those reported in the literature on lotto. This suggests that both sets of players share common psychological and cognitive traits and economic motivation. Those responsible for promoting pools should therefore be able to draw on findings from the much more extensive literature on lotto when formulating strategy in terms of game design and marketing.
Sultan, B; White, J A; Fish, R; Carrick, G; Brima, N; Copas, A; Robinson, A; Gilson, R; Mercey, D; Benn, P
2016-03-01
Triple-site testing (using pharyngeal, rectal, and urethral/first-void urine samples) for Neisseria gonorrhoeae and Chlamydia trachomatis using nucleic acid amplification tests detects greater numbers of infections among men who have sex with men (MSM). However, triple-site testing represents a cost pressure for services. MSM over 18 years of age were eligible if they requested testing for sexually transmitted infections (STIs), reported recent sexual contact with either C. trachomatis or N. gonorrhoeae, or had symptoms of an STI. Each patient underwent standard-of-care (SOC) triple-site testing, and swabs were taken to form a pooled sample (PS) (pharyngeal, rectal, and urine specimens). The PS was created using two methods during different periods at one clinic, but we analyzed the data in combination because the sensitivity of the two methods did not differ significantly for C. trachomatis (P = 0.774) or N. gonorrhoeae (P = 0.163). The sensitivity of PS testing (92%) was slightly lower than that of SOC testing (96%) for detecting C. trachomatis (P = 0.167). For N. gonorrhoeae, the sensitivity of PS testing (90%) was significantly lower than that of SOC testing (99%) (P < 0.001). When pharynx-only infections were excluded, the sensitivity of PS testing to detect N. gonorrhoeae infections increased to 94%. Our findings show that pooling of self-taken samples could be an effective and cost-saving method, with high negative predictive values. (Interim results of this study were presented at the BASHH 2013 summer meeting.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Grande, Antonio Jose; Reid, Hamish; Thomas, Emma; Foster, Charlie; Darton, Thomas C
2016-08-01
Dengue fever is a ubiquitous arboviral infection in tropical and sub-tropical regions, whose incidence has increased over recent decades. In the absence of a rapid point of care test, the clinical diagnosis of dengue is complex. The World Health Organisation has outlined diagnostic criteria for making the diagnosis of dengue infection, which includes the use of the tourniquet test (TT). To assess the quality of the evidence supporting the use of the TT and perform a diagnostic accuracy meta-analysis comparing the TT to antibody response measured by ELISA. A comprehensive literature search was conducted in the following databases to April, 2016: MEDLINE (PubMed), EMBASE, Cochrane Central Register of Controlled Trials, BIOSIS, Web of Science, SCOPUS. Studies comparing the diagnostic accuracy of the tourniquet test with ELISA for the diagnosis of dengue were included. Two independent authors extracted data using a standardized form. A total of 16 studies with 28,739 participants were included in the meta-analysis. Pooled sensitivity for dengue diagnosis by TT was 58% (95% Confidence Interval (CI), 43%-71%) and the specificity was 71% (95% CI, 60%-80%). In the subgroup analysis sensitivity for non-severe dengue diagnosis was 55% (95% CI, 52%-59%) and the specificity was 63% (95% CI, 60%-66%), whilst sensitivity for dengue hemorrhagic fever diagnosis was 62% (95% CI, 53%-71%) and the specificity was 60% (95% CI, 48%-70%). Receiver-operator characteristics demonstrated a test accuracy (AUC) of 0.70 (95% CI, 0.66-0.74). The tourniquet test is widely used in resource poor settings despite currently available evidence demonstrating only a marginal benefit in making a diagnosis of dengue infection alone. The protocol for this systematic review was registered at CRD42015020323.
Smith, Toby O; Drew, Benjamin T; Toms, Andoni P
2012-07-01
Magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA) have gained increasing favour in the assessment of patients with suspected glenoid labral injuries. The purpose of this study was to determine the diagnostic accuracy of MRI or MRA in the detection of gleniod labral lesions. A systematic review was undertaken of the electronic databases Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, AMED and CINAHL, in addition to a search of unpublished literature databases. All studies which compared the ability of MRI or MRA (index test) to assess gleniod labral tears or lesions, when verified with a surgical procedure (arthroscopy or open surgery-reference test) were included. Data extraction and methodological appraisal using the QUADAS tool were both conducted by two reviewers independently. Data were analysed through a summary receiver operator characteristic curve and pooled sensitivity and specificity analysis were calculated with 95% confidence intervals. Sixty studies including 4,667 shoulders from 4,574 patients were reviewed. There appeared slightly greater diagnostic test accuracy for MRA over MRI for the detection of overall gleniod labral lesions (MRA-sensitivity 88%, specificity 93% vs. MRI sensitivity 76% vs. specificity 87%). Methodologically, studies recruited and identified their samples appropriately and clearly defined the radiological procedures. In general, it was not clearly defined why patients were lost during the study, and studies were poor at recording whether the same clinical data were available to the radiologist interpreting the MRI or MRA as would be available in clinical practice. Most studies did not state whether the surgeon interpreting the arthroscopic procedure was blinded to the results of the MR or MRA imaging. Based on the available literature, overall MRA appeared marginally superior to MRI for the detection of glenohumeral labral lesions. Level 2a.
O’Caoimh, Rónán; Gao, Yang; Svendovski, Anton; Gallagher, Paul; Eustace, Joseph; Molloy, D. William
2017-01-01
Background: Although required to improve the usability of cognitive screening instruments (CSIs), the use of cut-off scores is controversial yet poorly researched. Objective: To explore cut-off scores for two short CSIs: the Standardized Mini-Mental State Examination (SMMSE) and Quick Mild Cognitive Impairment (Qmci) screen, describing adjustments in scores for diagnosis (MCI or dementia), age (≤, >75 years), and education (<, ≥12 years), comparing two methods: the maximal accuracy approach, derived from receiver operating characteristic curves, and Youden’s Index. Methods: Pooled analysis of assessments from patients attending memory clinics in Canada between 1999–2010 : 766 with mild cognitive impairment (MCI) and 1,746 with dementia, and 875 normal controls. Results: The Qmci was more accurate than the SMMSE in differentiating controls from MCI or cognitive impairment (MCI and dementia). Employing the maximal accuracy approach, the optimal SMMSE cut-off for cognitive impairment was <28/30 (AUC 0.86, sensitivity 74%, specificity 88%) versus <63/100 for the Qmci (AUC 0.93, sensitivity 85%, specificity 85%). Using Youden’s Index, the optimal SMMSE cut-off remained <28/30 but fell slightly to <62/100 for the Qmci (sensitivity 83%, specificity 87%). The optimal cut-off for MCI was <29/30 for the SMMSE and <67/100 for the Qmci, irrespective of technique. The maximal accuracy approach generally produced higher Qmci cut-offs than Youden’s Index, both requiring adjustment for age and education. There were no clinically meaningful differences in SMMSE cut-off scores by age and education or method employed. Conclusion: Caution should be exercised selecting cut-offs as these differ by age, education, and method of derivation, with the extent of adjustment varying between CSIs. PMID:28222528
Yoon, Hee Mang; Suh, Chong Hyun; Cho, Young Ah; Kim, Jeong Rye; Lee, Jin Seong; Jung, Ah Young; Kim, Jung Heon; Lee, Jeong-Yong; Kim, So Yeon
2018-06-01
To evaluate the diagnostic performance of reduced-dose CT for suspected appendicitis. A systematic search of the MEDLINE and EMBASE databases was carried out through to 10 January 2017. Studies evaluating the diagnostic performance of reduced-dose CT for suspected appendicitis in paediatric and adult patients were selected. Pooled summary estimates of sensitivity and specificity were calculated using hierarchical logistic regression modelling. Meta-regression was performed. Fourteen original articles with a total of 3,262 patients were included. For all studies using reduced-dose CT, the summary sensitivity was 96 % (95 % CI 93-98) with a summary specificity of 94 % (95 % CI 92-95). For the 11 studies providing a head-to-head comparison between reduced-dose CT and standard-dose CT, reduced-dose CT demonstrated a comparable summary sensitivity of 96 % (95 % CI 91-98) and specificity of 94 % (95 % CI 93-96) without any significant differences (p=.41). In meta-regression, there were no significant factors affecting the heterogeneity. The median effective radiation dose of the reduced-dose CT was 1.8 mSv (1.46-4.16 mSv), which was a 78 % reduction in effective radiation dose compared to the standard-dose CT. Reduced-dose CT shows excellent diagnostic performance for suspected appendicitis. • Reduced-dose CT shows excellent diagnostic performance for evaluating suspected appendicitis. • Reduced-dose CT has a comparable diagnostic performance to standard-dose CT. • Median effective radiation dose of reduced-dose CT was 1.8 mSv (1.46-4.16). • Reduced-dose CT achieved a 78 % dose reduction compared to standard-dose CT.
Value of physical tests in diagnosing cervical radiculopathy: a systematic review.
Thoomes, Erik J; van Geest, Sarita; van der Windt, Danielle A; Falla, Deborah; Verhagen, Arianne P; Koes, Bart W; Thoomes-de Graaf, Marloes; Kuijper, Barbara; Scholten-Peeters, Wendy G M; Vleggeert-Lankamp, Carmen L
2018-01-01
In clinical practice, the diagnosis of cervical radiculopathy is based on information from the patient's history, physical examination, and diagnostic imaging. Various physical tests may be performed, but their diagnostic accuracy is unknown. This study aimed to summarize and update the evidence on diagnostic performance of tests carried out during a physical examination for the diagnosis of cervical radiculopathy. A review of the accuracy of diagnostic tests was carried out. The study sample comprised diagnostic studies comparing results of tests performed during a physical examination in diagnosing cervical radiculopathy with a reference standard of imaging or surgical findings. Sensitivity, specificity, likelihood ratios are presented, together with pooled results for sensitivity and specificity. A literature search up to March 2016 was performed in CENTRAL, PubMed (MEDLINE), Embase, CINAHL, Web of Science, and Google Scholar. The methodological quality of studies was assessed using the QUADAS-2. Five diagnostic accuracy studies were identified. Only Spurling's test was evaluated in more than one study, showing high specificity ranging from 0.89 to 1.00 (95% confidence interval [CI]: 0.59-1.00); sensitivity varied from 0.38 to 0.97 (95% CI: 0.21-0.99). No studies were found that assessed the diagnostic accuracy of widely used neurological tests such as key muscle strength, tendon reflexes, and sensory impairments. There is limited evidence for accuracy of physical examination tests for the diagnosis of cervical radiculopathy. When consistent with patient history, clinicians may use a combination of Spurling's, axial traction, and an Arm Squeeze test to increase the likelihood of a cervical radiculopathy, whereas a combined results of four negative neurodynamics tests and an Arm Squeeze test could be used to rule out the disorder. Copyright © 2017 Elsevier Inc. All rights reserved.
Brusselaers, Nele; Labeau, Sonia; Vogelaers, Dirk; Blot, Stijn
2013-03-01
In ventilator-associated pneumonia (VAP), early appropriate antimicrobial therapy may be hampered by involvement of multidrug-resistant (MDR) pathogens. A systematic review and diagnostic test accuracy meta-analysis were performed to analyse whether lower respiratory tract surveillance cultures accurately predict the causative pathogens of subsequent VAP in adult patients. Selection and assessment of eligibility were performed by three investigators by mutual consideration. Of the 525 studies retrieved, 14 were eligible for inclusion (all in English; published since 1994), accounting for 791 VAP episodes. The following data were collected: study and population characteristics; in- and exclusion criteria; diagnostic criteria for VAP; microbiological workup of surveillance and diagnostic VAP cultures. Sub-analyses were conducted for VAP caused by Staphylococcus aureus, Pseudomonas spp., and Acinetobacter spp., MDR microorganisms, frequency of sampling, and consideration of all versus the most recent surveillance cultures. The meta-analysis showed a high accuracy of surveillance cultures, with pooled sensitivities up to 0.75 and specificities up to 0.92 in culture-positive VAP. The area under the curve (AUC) of the hierarchical summary receiver-operating characteristic curve demonstrates moderate accuracy (AUC: 0.90) in predicting multidrug resistance. A sampling frequency of >2/week (sensitivity 0.79; specificity 0.96) and consideration of only the most recent surveillance culture (sensitivity 0.78; specificity 0.96) are associated with a higher accuracy of prediction. This study provides evidence for the benefit of surveillance cultures in predicting MDR bacterial pathogens in VAP. However, clinical and statistical heterogeneity, limited samples sizes, and bias remain important limitations of this meta-analysis.
Can the Ni classification of vessels predict neoplasia? A systematic review and meta-analysis.
Mehlum, Camilla S; Rosenberg, Tine; Dyrvig, Anne-Kirstine; Groentved, Aagot Moeller; Kjaergaard, Thomas; Godballe, Christian
2018-01-01
The Ni classification of vascular change from 2011 is well documented for evaluating pharyngeal and laryngeal lesions, primarily focusing on cancer. In the planning of surgery it may be more relevant to differentiate neoplasia from non-neoplasia. We aimed to evaluate the ability of the Ni classification to predict laryngeal or hypopharyngeal neoplasia and to investigate if a changed cutoff value would support the recent European Laryngological Society (ELS) proposal of perpendicular vascular changes as indicative of neoplasia. PubMed, Embase, Cochrane, and Scopus databases. A systematic review and meta-analysis was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis statement. We systematically searched for publications from 2011 until 2016. All retrieved studies were reviewed and qualitatively assessed. The pooled sensitivity and specificity of the Ni classification with two different cutoffs were calculated, and bubble and summary receiver operating characteristics plots were created. The combined sensitivity of five studies (n = 687) with Ni type IV-V defined as test-positive was 0.89 (95% confidence interval [CI]: 0.76-0.95), and specificity was 0.82 (95% CI: 0.72-0.89). The equivalent combined sensitivity of four studies (n = 624) with Ni type V defined as test-positive was 0.82 (95% CI: 0.75-0.87), and specificity was 0.93 (95% CI: 0.82-0.97). The diagnostic accuracy of the Ni classification in predicting neoplasia was high, without significant difference between the two analyzed cutoff values. Implementation of the proposed ELS classification of vascular changes seems reasonable from a clinical perspective, with comparable accuracy. Attention must be drawn to the accompanying risk of exposing patients to unnecessary surgery. Laryngoscope, 128:168-176, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
B-type natriuretic peptides help in cardioembolic stroke diagnosis: pooled data meta-analysis.
Llombart, Víctor; Antolin-Fontes, Albert; Bustamante, Alejandro; Giralt, Dolors; Rost, Natalia S; Furie, Karen; Shibazaki, Kensaku; Biteker, Murat; Castillo, José; Rodríguez-Yáñez, Manuel; Fonseca, Ana Catarina; Watanabe, Tetsu; Purroy, Francisco; Zhixin, Wu; Etgen, Thorleif; Hosomi, Naohisa; Jafarian Kerman, Scott Reza; Sharma, Jagdish C; Knauer, Carolin; Santamarina, Estevo; Giannakoulas, George; García-Berrocoso, Teresa; Montaner, Joan
2015-05-01
Determining the underlying cause of stroke is important to optimize secondary prevention treatment. Increased blood levels of natriuretic peptides (B-type natriuretic peptide/N-terminal pro-BNP [BNP/NT-proBNP]) have been repeatedly associated with cardioembolic stroke. Here, we evaluate their clinical value as pathogenic biomarkers for stroke through a literature systematic review and individual participants' data meta-analysis. We searched publications in PubMed database until November 2013 that compared BNP and NT-proBNP circulating levels among stroke causes. Standardized individual participants' data were collected to estimate predictive values of BNP/NT-proBNP for cardioembolic stroke. Dichotomized BNP/NT-proBNP levels were included in logistic regression models together with clinical variables to assess the sensitivity and specificity to identify cardioembolic strokes and the additional value of biomarkers using area under the curve and integrated discrimination improvement index. From 23 selected articles, we collected information of 2834 patients with a defined cause. BNP/NT-proBNP levels were significantly elevated in cardioembolic stroke until 72 hours from symptoms onset. Predictive models showed a sensitivity >90% and specificity >80% when BNP/NT-proBNP were added considering the lowest and the highest quartile, respectively. Both peptides also increased significantly the area under the curve and integrated discrimination improvement index compared with clinical models. Sensitivity, specificity, and precision of the models were validated in 197 patients with initially undetermined stroke with final pathogenic diagnosis after ancillary follow-up. Natriuretic peptides are strongly increased in cardioembolic strokes. Future multicentre prospective studies comparing BNP and NT-proBNP might aid in finding the optimal biomarker, the best time point, and the optimal cutoff points for cardioembolic stroke identification. © 2015 American Heart Association, Inc.
López-Matas, M A; Moya, R; Cardona, V; Valero, A; Gaig, P; Malet, A; Viñas, M; García-Moral, A; Labrador, M; Alcoceba, E; Ibero, M; Carnés, J
The homologous group of sweet grasses belongs to the Pooideae subfamily, but grass pollen species from other subfamilies can also cause allergy, such as Cynodon dactylon (Chloridoideae) and Phragmites communis (Arundinoideae). C dactylon and P communis have not been included in the sweet grasses homologous group because of their low cross-reactivity with other grasses. The aims of this study were to investigate the profile of sensitization to C dactylon and P communis in patients sensitized to grasses and to analyze cross-reactivity between these 2 species and temperate grasses. Patients were skin prick tested with a grass mixture (GM). Specific IgE to GM, C dactylon, P communis, Cyn d 1, and Phl p 1 was measured by ImmunoCAP. A pool of sera was used for the immunoblot assays. Cross-reactivity was studied by ELISA and immunoblot inhibition. Thirty patients had sIgE to GM. Twenty-four (80%) had positive results for C dactylon, 27 (90%) for P communis, 22 (73.3%) for nCyn d 1, and 92.9% for rPhl p 1. Bands were detected in the 3 extracts by immunoblot. Inhibition of GM was not observed with C dactylon or P communis by immunoblot or ELISA inhibition. When C dactylon or P communis were used in the solid phase, GM produced almost complete inhibition. Eighty percent of patients sensitized to grasses were also sensitized to C dactylon and 90% were sensitized to P communis. Sensitization to these species seems to be induced by allergens different to those in sweet grasses.
do Amaral, Pedro Henrique Monteiro; da Silveira, Lidimara Souza; Rosa, Beatriz Figueiraujo Jabour Vescovi; de Oliveira, Vívian Campos; Alves, Roberto da Gama
2015-01-01
Insects of the orders Ephemeroptera, Plecoptera, and Trichoptera (EPT) are often used to assess the conditions of aquatic environments, but few studies have examined the differences in these communities between riffles and pools. Our objective was to test whether riffles shelter greater richness and abundance of EPT, as well as to assess the sensitivity of these insects for detecting impacts from different land uses in streams in southeastern Brazil. Samples were collected in the dry season of 2012 with a Surber sampler in riffles and pools of nine streams (forest, pasture, and urban areas). Principal component analysis distinguished the streams according to different land uses as a function of percentage of plant cover and water oxygenation level and showed partial distinction between riffles and pools as a function of current speed and percentage of ultrafine sand. Detrended correspondence analysis indicated the distinction in EPT composition between riffles and pools, except in urban streams. The results of this study confirm the expected differences in the EPT fauna structure between riffles and pools, especially in forest and pasture environments. The individual metrics of riffle and pool assemblages showed significantly different responses to land use. Therefore, we suggest individual sampling of riffles and pools, since the metrics of these assemblages’ insects can differ between these habitats and influence the results of assessments in low-order streams. PMID:25989807
NASA Astrophysics Data System (ADS)
Kellman, L. M.; Gabriel, C. E.
2015-12-01
Soil organic matter (SOM) in northern forest soils is associated with a suite of minerals that can confer SOM stability, resulting in the potential for long-term storage of carbon. Increasingly, evidence is suggesting that SOM in certain mineral phases is dynamic and vulnerable to soil disturbance. The objective of this research was to investigate changes in a suite of mineral-associated pools of SOM through depth in a temperate forest soil to determine which mineral-associated carbon pools are most sensitive to forest harvesting disturbance. Sequential selective dissolutions representing increasingly stable SOM pools (soluble minerals (deionized water); humus-mineral complexes (Na-pyrophosphate); poorly crystalline minerals (HCl hydroxylamine); and crystalline secondary minerals (Na-dithionite + HCl)) of mineral soils through depth to 50 cm were carried out in podzolic soils sampled from temperate red spruce forests of contrasting stand age in Nova Scotia, Canada. Results of this analysis point to a loss of carbon from SOM within the B-horizon of the most recently harvested site from the pyrophosphate-extracted humus mineral complexed SOM, suggesting that it is this exchangeable pool that appears to be destabilized following clearcut harvesting at these study sites. This suggests that recovery from this landuse disturbance is dependent upon increasing storage of this SOM pool, and that mineral-associated pools, particularly pyrophosphate-extractable SOM, may be a useful indicator of changes to soil carbon storage following land use change.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heiple, C.R.; Burgardt, P.
1990-01-01
The size and shape of the weld bead produced in GTA welding depends on the magnitude and distribution of the energy incident on the workpiece surfaces as well as the dissipation of that energy in the workpiece. The input energy is largely controllable through the welding parameters selected, however the dissipation of that energy in the workpiece is less subject to control. Changes in energy dissipation can produce large changes in weld shape or penetration. Heat transport away from the weld pool is almost entirely by conduction, but heat transport in the weld pool is more complicated. Heat conduction throughmore » the liquid is an important component, but heat transport by convection (mass transport) is often the dominant mechanism. Convective heat transport is directional and changes the weld pool shape from that produced by conduction alone. Surface tension gradients are often the dominant forces driving fluid flow in GTA weld pools. These gradients are sensitive functions of weld pool chemistry and the energy input distribution to the weld. Experimental and theoretical work conducted primarily in the past decade has greatly enhanced our understanding of weld pool fluid flow, the forces which drive it, and its effects on weld pool shape. This work is reviewed here. While less common, changes in energy dissipation through the unmelted portion of the workpiece can also affect fusion zone shape or penetration. These effects are also described. 41 refs., 9 figs.« less
Annual report, FY 1979 Spent fuel and fuel pool component integrity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, A.B. Jr.; Bailey, W.J.; Schreiber, R.E.
International meetings under the BEFAST program and under INFCE Working Group No. 6 during 1978 and 1979 continue to indicate that no cases of fuel cladding degradation have developed on pool-stored fuel from water reactors. A section from a spent fuel rack stand, exposed for 1.5 y in the Yankee Rowe (PWR) pool had 0.001- to 0.003-in.-deep (25- to 75-..mu..m) intergranular corrosion in weld heat-affected zones but no evidence of stress corrosion cracking. A section of a 304 stainless steel spent fuel storage rack exposed 6.67 y in the Point Beach reactor (PWR) spent fuel pool showed no significant corrosion.more » A section of 304 stainless steel 8-in.-dia pipe from the Three Mile Island No. 1 (PWR) spent fuel pool heat exchanger plumbing developed a through-wall crack. The crack was intergranular, initiating from the inside surface in a weld heat-affected zone. The zone where the crack occurred was severely sensitized during field welding. The Kraftwerk Union (Erlangen, GFR) disassembled a stainless-steel fuel-handling machine that operated for 12 y in a PWR (boric acid) spent fuel pool. There was no evidence of deterioration, and the fuel-handling machine was reassembled for further use. A spent fuel pool at a Swedish PWR was decontaminated. The procedure is outlined in this report.« less
van Dijk, R; van Assen, M; Vliegenthart, R; de Bock, G H; van der Harst, P; Oudkerk, M
2017-11-27
Stress cardiovascular magnetic resonance (CMR) perfusion imaging is a promising modality for the evaluation of coronary artery disease (CAD) due to high spatial resolution and absence of radiation. Semi-quantitative and quantitative analysis of CMR perfusion are based on signal-intensity curves produced during the first-pass of gadolinium contrast. Multiple semi-quantitative and quantitative parameters have been introduced. Diagnostic performance of these parameters varies extensively among studies and standardized protocols are lacking. This study aims to determine the diagnostic accuracy of semi- quantitative and quantitative CMR perfusion parameters, compared to multiple reference standards. Pubmed, WebOfScience, and Embase were systematically searched using predefined criteria (3272 articles). A check for duplicates was performed (1967 articles). Eligibility and relevance of the articles was determined by two reviewers using pre-defined criteria. The primary data extraction was performed independently by two researchers with the use of a predefined template. Differences in extracted data were resolved by discussion between the two researchers. The quality of the included studies was assessed using the 'Quality Assessment of Diagnostic Accuracy Studies Tool' (QUADAS-2). True positives, false positives, true negatives, and false negatives were subtracted/calculated from the articles. The principal summary measures used to assess diagnostic accuracy were sensitivity, specificity, andarea under the receiver operating curve (AUC). Data was pooled according to analysis territory, reference standard and perfusion parameter. Twenty-two articles were eligible based on the predefined study eligibility criteria. The pooled diagnostic accuracy for segment-, territory- and patient-based analyses showed good diagnostic performance with sensitivity of 0.88, 0.82, and 0.83, specificity of 0.72, 0.83, and 0.76 and AUC of 0.90, 0.84, and 0.87, respectively. In per territory analysis our results show similar diagnostic accuracy comparing anatomical (AUC 0.86(0.83-0.89)) and functional reference standards (AUC 0.88(0.84-0.90)). Only the per territory analysis sensitivity did not show significant heterogeneity. None of the groups showed signs of publication bias. The clinical value of semi-quantitative and quantitative CMR perfusion analysis remains uncertain due to extensive inter-study heterogeneity and large differences in CMR perfusion acquisition protocols, reference standards, and methods of assessment of myocardial perfusion parameters. For wide spread implementation, standardization of CMR perfusion techniques is essential. CRD42016040176 .
The problem and promise of scale dependency in community phylogenetics.
Swenson, Nathan G; Enquist, Brian J; Pither, Jason; Thompson, Jill; Zimmerman, Jess K
2006-10-01
The problem of scale dependency is widespread in investigations of ecological communities. Null model investigations of community assembly exemplify the challenges involved because they typically include subjectively defined "regional species pools." The burgeoning field of community phylogenetics appears poised to face similar challenges. Our objective is to quantify the scope of the problem of scale dependency by comparing the phylogenetic structure of assemblages across contrasting geographic and taxonomic scales. We conduct phylogenetic analyses on communities within three tropical forests, and perform a sensitivity analysis with respect to two scaleable inputs: taxonomy and species pool size. We show that (1) estimates of phylogenetic overdispersion within local assemblages depend strongly on the taxonomic makeup of the local assemblage and (2) comparing the phylogenetic structure of a local assemblage to a species pool drawn from increasingly larger geographic scales results in an increased signal of phylogenetic clustering. We argue that, rather than posing a problem, "scale sensitivities" are likely to reveal general patterns of diversity that could help identify critical scales at which local or regional influences gain primacy for the structuring of communities. In this way, community phylogenetics promises to fill an important gap in community ecology and biogeography research.
Feltner, Cynthia; Grodensky, Catherine; Ebel, Charles; Middleton, Jennifer C; Harris, Russell P; Ashok, Mahima; Jonas, Daniel E
2016-12-20
Genital herpes simplex virus (HSV) infection is a prevalent sexually transmitted infection. Vertical transmission of HSV can lead to fetal morbidity and mortality. To assess the evidence on serologic screening and preventive interventions for genital HSV infection in asymptomatic adults and adolescents to support the US Preventive Services Task Force for an updated recommendation statement. MEDLINE, Cochrane Library, EMBASE, and trial registries through March 31, 2016. Surveillance for new evidence in targeted publications was conducted through October 31, 2016. English-language randomized clinical trials (RCTs) comparing screening with no screening in persons without past or current symptoms of genital herpes; studies evaluating accuracy and harms of serologic screening tests for HSV-2; RCTs assessing preventive interventions in asymptomatic persons seropositive for HSV-2. Dual review of abstracts, full-text articles, and study quality; pooled sensitivities and specificities of screening tests using a hierarchical summary receiver operating characteristic curve analysis when at least 3 similar studies were available. Accuracy of screening tests, benefits of screening, harms of screening, reduction in genital herpes outbreaks. A total of 17 studies (n = 9736 participants; range, 24-3290) in 19 publications were included. No RCTs compared screening with no screening. Most studies of the accuracy of screening tests were from populations with high HSV-2 prevalence (greater than 40% based on Western blot). Pooled estimates of sensitivity and specificity of the most commonly used test at the manufacturer's cutpoint were 99% (95% CI, 97%-100%) and 81% (95% CI, 68%-90%), respectively (10 studies; n = 6537). At higher cutpoints, pooled estimates were 95% (95% CI, 91%-97%) and 89% (95% CI, 82%-93%), respectively (7 studies; n = 5516). Use of this test at the manufacturer's cutpoint in a population of 100 000 with a prevalence of HSV-2 of 16% (the seroprevalence in US adults with unknown symptom status) would result in 15 840 true-positive results and 15 960 false-positive results (positive predictive value, 50%). Serologic screening for genital herpes was associated with psychosocial harms, including distress and anxiety related to positive test results. Four RCTs compared preventive medications with placebo, 2 in nonpregnant asymptomatic adults who were HSV-2 seropositive and 2 in HSV-2-serodiscordant couples. Results in both populations were heterogeneous and inconsistent. Serologic screening for genital herpes is associated with a high rate of false-positive test results and potential psychosocial harms. Evidence from RCTs does not establish whether preventive antiviral medication for asymptomatic HSV-2 infection has benefit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Litvinov, Julia; Moen, Scott T.; Berry, Gregory J.
Infection with Mycobacterium Tuberculosis represents a significant threat to people with immune disorders, such as HIV-positive individuals, and can result in significant health complications or death if not diagnosed and treated early. We present a centrifugal microfluidic platform for multiplexed detection of tuberculosis and HIV biomarkers in human whole blood with minimal sample preparation and a sample-to-answer time of 30 minutes. This multiplexed assay was developed for the detection of two M.tuberculosis secreted proteins, whose secretion represents an active and ongoing infection, as well as detection of HIV p24 protein and human anti-p24 antibodies. The limit of detection for thismore » multiplex assay is in the pg/mL range for both HIV and M.tuberculosis proteins, making this assay potentially useful in the clinical diagnosis of both HIV and Tuberculosis proteins indicative of active infection. Antigen detection for the HIV assay sensitivity was 89%, the specificity 85%. Serological detection had 100% sensitivity and specificity for the limited sample pool. The centrifugal microfluidic platform presented here offers the potential for a portable, fast and inexpensive multiplexed diagnostic device that can be used in resource-limited settings for diagnosis of TB and HIV.« less
Litvinov, Julia; Moen, Scott T.; Berry, Gregory J.; ...
2017-05-30
Infection with Mycobacterium Tuberculosis represents a significant threat to people with immune disorders, such as HIV-positive individuals, and can result in significant health complications or death if not diagnosed and treated early. We present a centrifugal microfluidic platform for multiplexed detection of tuberculosis and HIV biomarkers in human whole blood with minimal sample preparation and a sample-to-answer time of 30 minutes. This multiplexed assay was developed for the detection of two M.tuberculosis secreted proteins, whose secretion represents an active and ongoing infection, as well as detection of HIV p24 protein and human anti-p24 antibodies. The limit of detection for thismore » multiplex assay is in the pg/mL range for both HIV and M.tuberculosis proteins, making this assay potentially useful in the clinical diagnosis of both HIV and Tuberculosis proteins indicative of active infection. Antigen detection for the HIV assay sensitivity was 89%, the specificity 85%. Serological detection had 100% sensitivity and specificity for the limited sample pool. The centrifugal microfluidic platform presented here offers the potential for a portable, fast and inexpensive multiplexed diagnostic device that can be used in resource-limited settings for diagnosis of TB and HIV.« less
Koehne, Guenther; Hasan, Aisha; Doubrovina, Ekaterina; Prockop, Susan; Tyler, Eleanor; Wasilewski, Gloria; O’Reilly, Richard J.
2015-01-01
We conducted a Phase I trial of allogeneic T-cells sensitized in vitro against a pool of 15-mer peptides spanning the sequence of CMVpp65 for adoptive therapy of 17 allogeneic hematopoietic cell transplant recipients with CMV viremia or clinical infection persisting despite prolonged treatment with antiviral drugs. All but three of the patients had received T-cell depleted transplants without GVHD prophylaxis with immunosuppressive drugs post transplant. The CMVpp65-specific T-cells (CMVpp65CTLs) generated were oligoclonal and specific for only 1–3 epitopes, presented by a limited set of HLA class I or II alleles. T-cell infusions were well tolerated without toxicity or GVHD. Of 17 patients treated with transplant donor (N=16) or third party (N=1) CMVpp65CTLs, 15 cleared viremia including 3 of 5 with overt disease. In responding patients, the CMVpp65CTLs infused consistently proliferated and could be detected by T-cell receptor (TCR) Vβ usage in CMVpp65/HLA tetramer+ populations for period of 120 days to up to 2 years post infusion. Thus, CMVpp65CTLs generated in response to synthetic 15-mer peptides of CMVpp65 are safe and can clear persistent CMV infections in the post transplant period. PMID:26028505
Sensitive kinase assay linked with phosphoproteomics for identifying direct kinase substrates
Xue, Liang; Wang, Wen-Horng; Iliuk, Anton; Hu, Lianghai; Galan, Jacob A.; Yu, Shuai; Hans, Michael; Geahlen, Robert L.; Tao, W. Andy
2012-01-01
Our understanding of the molecular control of many disease pathologies requires the identification of direct substrates targeted by specific protein kinases. Here we describe an integrated proteomic strategy, termed kinase assay linked with phosphoproteomics, which combines a sensitive kinase reaction with endogenous kinase-dependent phosphoproteomics to identify direct substrates of protein kinases. The unique in vitro kinase reaction is carried out in a highly efficient manner using a pool of peptides derived directly from cellular kinase substrates and then dephosphorylated as substrate candidates. The resulting newly phosphorylated peptides are then isolated and identified by mass spectrometry. A further comparison of these in vitro phosphorylated peptides with phosphopeptides derived from endogenous proteins isolated from cells in which the kinase is either active or inhibited reveals new candidate protein substrates. The kinase assay linked with phosphoproteomics strategy was applied to identify unique substrates of spleen tyrosine kinase (Syk), a protein-tyrosine kinase with duel properties of an oncogene and a tumor suppressor in distinctive cell types. We identified 64 and 23 direct substrates of Syk specific to B cells and breast cancer cells, respectively. Both known and unique substrates, including multiple centrosomal substrates for Syk, were identified, supporting a unique mechanism that Syk negatively affects cell division through its centrosomal kinase activity. PMID:22451900
Impact of atmospheric and terrestrial CO2 feedbacks on fertilization-induced marine carbon uptake
NASA Astrophysics Data System (ADS)
Oschlies, A.
2009-08-01
The sensitivity of oceanic CO2 uptake to alterations in the marine biological carbon pump, such as brought about by natural or purposeful ocean fertilization, has repeatedly been investigated by studies employing numerical biogeochemical ocean models. It is shown here that the results of such ocean-centered studies are very sensitive to the assumption made about the response of the carbon reservoirs on the atmospheric side of the sea surface. Assumptions made include prescribed atmospheric pCO2, an interactive atmospheric CO2 pool exchanging carbon with the ocean but not with the terrestrial biosphere, and an interactive atmosphere that exchanges carbon with both oceanic and terrestrial carbon pools. The impact of these assumptions on simulated annual to millennial oceanic carbon uptake is investigated for a hypothetical increase in the C:N ratio of the biological pump and for an idealized enhancement of phytoplankton growth. Compared to simulations with interactive atmosphere, using prescribed atmospheric pCO2 overestimates the sensitivity of the oceanic CO2 uptake to changes in the biological pump, by about 2%, 25%, 100%, and >500% on annual, decadal, centennial, and millennial timescales, respectively. The smaller efficiency of the oceanic carbon uptake under an interactive atmosphere is due to the back flux of CO2 that occurs when atmospheric CO2 is reduced. Adding an interactive terrestrial carbon pool to the atmosphere-ocean model system has a small effect on annual timescales, but increases the simulated fertilization-induced oceanic carbon uptake by about 4%, 50%, and 100% on decadal, centennial, and millennial timescales, respectively, for pCO2 sensitivities of the terrestrial carbon storage in the middle range of the C4MIP models (Friedlingstein et al., 2006). For such sensitivities, a substantial fraction of oceanic carbon uptake induced by natural or purposeful ocean fertilization originates, on timescales longer than decades, not from the atmosphere but from the terrestrial biosphere.