Martin, Jeffrey D.
2002-01-01
Correlation analysis indicates that for most pesticides and concentrations, pooled estimates of relative standard deviation rather than pooled estimates of standard deviation should be used to estimate variability because pooled estimates of relative standard deviation are less affected by heteroscedasticity. The 2 Variability of Pesticide Detections and Concentrations in Field Replicate Water Samples, 1992–97 median pooled relative standard deviation was calculated for all pesticides to summarize the typical variability for pesticide data collected for the NAWQA Program. The median pooled relative standard deviation was 15 percent at concentrations less than 0.01 micrograms per liter (µg/L), 13 percent at concentrations near 0.01 µg/L, 12 percent at concentrations near 0.1 µg/L, 7.9 percent at concentrations near 1 µg/L, and 2.7 percent at concentrations greater than 5 µg/L. Pooled estimates of standard deviation or relative standard deviation presented in this report are larger than estimates based on averages, medians, smooths, or regression of the individual measurements of standard deviation or relative standard deviation from field replicates. Pooled estimates, however, are the preferred method for characterizing variability because they provide unbiased estimates of the variability of the population. Assessments of variability based on standard deviation (rather than variance) underestimate the true variability of the population. Because pooled estimates of variability are larger than estimates based on other approaches, users of estimates of variability must be cognizant of the approach used to obtain the estimate and must use caution in the comparison of estimates based on different approaches.
Selection and Classification Using a Forecast Applicant Pool.
ERIC Educational Resources Information Center
Hendrix, William H.
The document presents a forecast model of the future Air Force applicant pool. By forecasting applicants' quality (means and standard deviations of aptitude scores) and quantity (total number of applicants), a potential enlistee could be compared to the forecasted pool. The data used to develop the model consisted of means, standard deviation, and…
Sparse feature learning for instrument identification: Effects of sampling and pooling methods.
Han, Yoonchang; Lee, Subin; Nam, Juhan; Lee, Kyogu
2016-05-01
Feature learning for music applications has recently received considerable attention from many researchers. This paper reports on the sparse feature learning algorithm for musical instrument identification, and in particular, focuses on the effects of the frame sampling techniques for dictionary learning and the pooling methods for feature aggregation. To this end, two frame sampling techniques are examined that are fixed and proportional random sampling. Furthermore, the effect of using onset frame was analyzed for both of proposed sampling methods. Regarding summarization of the feature activation, a standard deviation pooling method is used and compared with the commonly used max- and average-pooling techniques. Using more than 47 000 recordings of 24 instruments from various performers, playing styles, and dynamics, a number of tuning parameters are experimented including the analysis frame size, the dictionary size, and the type of frequency scaling as well as the different sampling and pooling methods. The results show that the combination of proportional sampling and standard deviation pooling achieve the best overall performance of 95.62% while the optimal parameter set varies among the instrument classes.
Wang, Chun; Zheng, Yi; Chang, Hua-Hua
2014-01-01
With the advent of web-based technology, online testing is becoming a mainstream mode in large-scale educational assessments. Most online tests are administered continuously in a testing window, which may post test security problems because examinees who take the test earlier may share information with those who take the test later. Researchers have proposed various statistical indices to assess the test security, and one most often used index is the average test-overlap rate, which was further generalized to the item pooling index (Chang & Zhang, 2002, 2003). These indices, however, are all defined as the means (that is, the expected proportion of common items among examinees) and they were originally proposed for computerized adaptive testing (CAT). Recently, multistage testing (MST) has become a popular alternative to CAT. The unique features of MST make it important to report not only the mean, but also the standard deviation (SD) of test overlap rate, as we advocate in this paper. The standard deviation of test overlap rate adds important information to the test security profile, because for the same mean, a large SD reflects that certain groups of examinees share more common items than other groups. In this study, we analytically derived the lower bounds of the SD under MST, with the results under CAT as a benchmark. It is shown that when the mean overlap rate is the same between MST and CAT, the SD of test overlap tends to be larger in MST. A simulation study was conducted to provide empirical evidence. We also compared the security of MST under the single-pool versus the multiple-pool designs; both analytical and simulation studies show that the non-overlapping multiple-pool design will slightly increase the security risk.
Tests for qualitative treatment-by-centre interaction using a 'pushback' procedure.
Ciminera, J L; Heyse, J F; Nguyen, H H; Tukey, J W
1993-06-15
In multicentre clinical trials using a common protocol, the centres are usually regarded as being a fixed factor, thus allowing any treatment-by-centre interaction to be omitted from the error term for the effect of treatment. However, we feel it necessary to use the treatment-by-centre interaction as the error term if there is substantial evidence that the interaction with centres is qualitative instead of quantitative. To make allowance for the estimated uncertainties of the centre means, we propose choosing a reference value (for example, the median of the ordered array of centre means) and converting the individual centre results into standardized deviations from the reference value. The deviations are then reordered, and the results 'pushed back' by amounts appropriate for the corresponding order statistics in a sample from the relevant distribution. The pushed-back standardized deviations are then restored to the original scale. The appearance of opposite signs among the destandardized values for the various centres is then taken as 'substantial evidence' of qualitative interaction. Procedures are presented using, in any combination: (i) Gaussian, or Student's t-distribution; (ii) order-statistic medians or outward 90 per cent points of the corresponding order statistic distributions; (iii) pooling or grouping and pooling the internally estimated standard deviations of the centre means. The use of the least conservative combination--Student's t, outward 90 per cent points, grouping and pooling--is recommended.
Maternal Exposure to Bisphenol-A and Fetal Growth Restriction: A Case-Referent Study
Burstyn, Igor; Martin, Jonathan W.; Beesoon, Sanjay; Bamforth, Fiona; Li, Qiaozhi; Yasui, Yutaka; Cherry, Nicola M.
2013-01-01
We conducted a case-referent study of the effect of exposure to bisphenol-A on fetal growth in utero in full-term, live-born singletons in Alberta, Canada. Newborns <10 percentile of expected weight for gestational age and sex were individually matched on sex, maternal smoking and maternal age to referents with weight appropriate to gestational age. Exposure of the fetus to bisphenol-A was estimated from maternal serum collected at 15–16 weeks of gestation. We pooled sera across subjects for exposure assessment, stratified on case-referent status and sex. Individual 1:1 matching was maintained in assembling 69 case and 69 referent pools created from 550 case-referent pairs. Matched pools had an equal number of aliquots from individual women. We used an analytical strategy conditioning on matched set and total pool-level values of covariates to estimate individual-level effects. Pools of cases and referents had identical geometric mean bisphenol-A concentrations (0.5 ng/mL) and similar geometric standard deviations (2.3–2.5). Mean difference in concentration between matched pools was 0 ng/mL, standard deviation: 1 ng/mL. Stratification by sex and control for confounding did not suggest bisphenol-A increased fetal growth restriction. Our analysis does not provide evidence to support the hypothesis that bisphenol-A contributes to fetal growth restriction in full-term singletons. PMID:24336026
22st Annual National Test and Evaluation Conference
2006-03-09
B1 B2 y ii) Factor B affects the standard deviation C2 C1 y iii) Factor C affects the average and the standard deviation D1 = D2 y iv) Factor D has...22303 UNITED STATES (P) (703)862-0908 (F) (703)970-5700 poole_grady@emc.com Mr. Josh Pressnell RTI 8306 Rugby Rd. Manassas, VA 20111...Ricciardi RTI 8306 Rugby Rd. Manassas, VA 20111-1912 UNITED STATES (P) (703)365-9662 (F) (703)365-9818 michael.ricciardi@rti-world.com Mr
Composting Explosives/Organics Contaminated Soils
1986-05-01
29 144. Quantitation of C Trapped by Activated Carbon . ... 29 5. Preliminary Extraction Trials .... ........ ..... . 30 6. Tetryl Product...ppm (standard deviation 1892 ppm). All samples of soil from Letterkenny AD were pooled to yield one composite sample. Pooled samples from Louisiana...combustion efficiency, and counting efficiency. 4. Quantitation of 14 C Trapped by Activated Carbon Random subsamples of carbon from the air intake
Wan, Xiang; Wang, Wenqian; Liu, Jiming; Tong, Tiejun
2014-12-19
In systematic reviews and meta-analysis, researchers often pool the results of the sample mean and standard deviation from a set of similar clinical trials. A number of the trials, however, reported the study using the median, the minimum and maximum values, and/or the first and third quartiles. Hence, in order to combine results, one may have to estimate the sample mean and standard deviation for such trials. In this paper, we propose to improve the existing literature in several directions. First, we show that the sample standard deviation estimation in Hozo et al.'s method (BMC Med Res Methodol 5:13, 2005) has some serious limitations and is always less satisfactory in practice. Inspired by this, we propose a new estimation method by incorporating the sample size. Second, we systematically study the sample mean and standard deviation estimation problem under several other interesting settings where the interquartile range is also available for the trials. We demonstrate the performance of the proposed methods through simulation studies for the three frequently encountered scenarios, respectively. For the first two scenarios, our method greatly improves existing methods and provides a nearly unbiased estimate of the true sample standard deviation for normal data and a slightly biased estimate for skewed data. For the third scenario, our method still performs very well for both normal data and skewed data. Furthermore, we compare the estimators of the sample mean and standard deviation under all three scenarios and present some suggestions on which scenario is preferred in real-world applications. In this paper, we discuss different approximation methods in the estimation of the sample mean and standard deviation and propose some new estimation methods to improve the existing literature. We conclude our work with a summary table (an Excel spread sheet including all formulas) that serves as a comprehensive guidance for performing meta-analysis in different situations.
Mathur, Aabhas; Chowdhury, Raquibul; Hillyer, Christopher D; Mitchell, W Beau; Shaz, Beth H
2016-12-01
Each unit of blood donated is processed and stored individually resulting in variability in the amount of red blood cells (RBCs) collected, RBC properties, and the 24-hour posttransfusion RBC survivability. As a result, each unit differs in its ability to deliver oxygen and potentially its effects on the recipient. The goal of this study was to investigate the storage of pooled RBCs from multiple donors in comparison to control standard RBC units. Two units of irradiated, leukoreduced RBCs of same ABO, D, E, C, and K antigen phenotype were collected from each of five donors using apheresis. One unit from each donor was pooled in a 2-L bag and remaining units were used as controls. After being pooled, RBCs were separated in five bags and stored at 4°C along with the controls. Quality indexes were measured on Days 2, 14, and 28 for all the units. Adenosine triphosphate assays for both pooled and controls showed a slight decrease from Day 2 to Day 28 (pooled/control from 5.22/5.24 to 4.35/4.33 µmol/g hemoglobin [Hb]). 2,3-Diphosphoglycerate was successfully rejuvenated for all RBC units on Day 28 (pooled 11.46 µmol/g Hb; control 11.86 µmol/g Hb). The results showed a nonsignificant difference between pooled and control units, with a general trend of lower standard deviation for pooled units when compared to controls. Pooled units have reduced unit-to-unit variability. Future exploration of their immunogenicity is required before using pooled units for transfusion. © 2016 AABB.
Welding deviation detection algorithm based on extremum of molten pool image contour
NASA Astrophysics Data System (ADS)
Zou, Yong; Jiang, Lipei; Li, Yunhua; Xue, Long; Huang, Junfen; Huang, Jiqiang
2016-01-01
The welding deviation detection is the basis of robotic tracking welding, but the on-line real-time measurement of welding deviation is still not well solved by the existing methods. There is plenty of information in the gas metal arc welding(GMAW) molten pool images that is very important for the control of welding seam tracking. The physical meaning for the curvature extremum of molten pool contour is revealed by researching the molten pool images, that is, the deviation information points of welding wire center and the molten tip center are the maxima and the local maxima of the contour curvature, and the horizontal welding deviation is the position difference of these two extremum points. A new method of weld deviation detection is presented, including the process of preprocessing molten pool images, extracting and segmenting the contours, obtaining the contour extremum points, and calculating the welding deviation, etc. Extracting the contours is the premise, segmenting the contour lines is the foundation, and obtaining the contour extremum points is the key. The contour images can be extracted with the method of discrete dyadic wavelet transform, which is divided into two sub contours including welding wire and molten tip separately. The curvature value of each point of the two sub contour lines is calculated based on the approximate curvature formula of multi-points for plane curve, and the two points of the curvature extremum are the characteristics needed for the welding deviation calculation. The results of the tests and analyses show that the maximum error of the obtained on-line welding deviation is 2 pixels(0.16 mm), and the algorithm is stable enough to meet the requirements of the pipeline in real-time control at a speed of less than 500 mm/min. The method can be applied to the on-line automatic welding deviation detection.
Accuracy of Digital vs. Conventional Implant Impressions
Lee, Sang J.; Betensky, Rebecca A.; Gianneschi, Grace E.; Gallucci, German O.
2015-01-01
The accuracy of digital impressions greatly influences the clinical viability in implant restorations. The aim of this study is to compare the accuracy of gypsum models acquired from the conventional implant impression to digitally milled models created from direct digitalization by three-dimensional analysis. Thirty gypsum and 30 digitally milled models impressed directly from a reference model were prepared. The models were scanned by a laboratory scanner and 30 STL datasets from each group were imported to an inspection software. The datasets were aligned to the reference dataset by a repeated best fit algorithm and 10 specified contact locations of interest were measured in mean volumetric deviations. The areas were pooled by cusps, fossae, interproximal contacts, horizontal and vertical axes of implant position and angulation. The pooled areas were statistically analysed by comparing each group to the reference model to investigate the mean volumetric deviations accounting for accuracy and standard deviations for precision. Milled models from digital impressions had comparable accuracy to gypsum models from conventional impressions. However, differences in fossae and vertical displacement of the implant position from the gypsum and digitally milled models compared to the reference model, exhibited statistical significance (p<0.001, p=0.020 respectively). PMID:24720423
[Effect strength variation in the single group pre-post study design: a critical review].
Maier-Riehle, B; Zwingmann, C
2000-08-01
In Germany, studies in rehabilitation research--in particular evaluation studies and examinations of quality of outcome--have so far mostly been executed according to the uncontrolled one-group pre-post design. Assessment of outcome is usually made by comparing the pre- and post-treatment means of the outcome variables. The pre-post differences are checked, and in case of significance, the results are increasingly presented in form of effect sizes. For this reason, this contribution presents different effect size indices used for the one-group pre-post design--in spite of fundamental doubts which exist in relation to that design due to its limited internal validity. The numerator concerning all effect size indices of the one-group pre-post design is defined as difference between the pre- and post-treatment means, whereas there are different possibilities and recommendations with regard to the denominator and hence the standard deviation that serves as the basis for standardizing the difference of the means. Used above all are standardization oriented towards the standard deviation of the pre-treatment scores, standardization oriented towards the pooled standard deviation of the pre- and post-treatment scores, and standardization oriented towards the standard deviation of the pre-post differences. Two examples are given to demonstrate that the different modes of calculating effect size indices in the one-group pre-post design may lead to very different outcome patterns. Additionally, it is pointed out that effect sizes from the uncontrolled one-group pre-post design generally tend to be higher than effect sizes from studies conducted with control groups. Finally, the pros and cons of the different effect size indices are discussed and recommendations are given.
A framework for the meta-analysis of Bland-Altman studies based on a limits of agreement approach.
Tipton, Elizabeth; Shuster, Jonathan
2017-10-15
Bland-Altman method comparison studies are common in the medical sciences and are used to compare a new measure to a gold-standard (often costlier or more invasive) measure. The distribution of these differences is summarized by two statistics, the 'bias' and standard deviation, and these measures are combined to provide estimates of the limits of agreement (LoA). When these LoA are within the bounds of clinically insignificant differences, the new non-invasive measure is preferred. Very often, multiple Bland-Altman studies have been conducted comparing the same two measures, and random-effects meta-analysis provides a means to pool these estimates. We provide a framework for the meta-analysis of Bland-Altman studies, including methods for estimating the LoA and measures of uncertainty (i.e., confidence intervals). Importantly, these LoA are likely to be wider than those typically reported in Bland-Altman meta-analyses. Frequently, Bland-Altman studies report results based on repeated measures designs but do not properly adjust for this design in the analysis. Meta-analyses of Bland-Altman studies frequently exclude these studies for this reason. We provide a meta-analytic approach that allows inclusion of estimates from these studies. This includes adjustments to the estimate of the standard deviation and a method for pooling the estimates based upon robust variance estimation. An example is included based on a previously published meta-analysis. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
An image registration based ultrasound probe calibration
NASA Astrophysics Data System (ADS)
Li, Xin; Kumar, Dinesh; Sarkar, Saradwata; Narayanan, Ram
2012-02-01
Reconstructed 3D ultrasound of prostate gland finds application in several medical areas such as image guided biopsy, therapy planning and dose delivery. In our application, we use an end-fire probe rotated about its axis to acquire a sequence of rotational slices to reconstruct 3D TRUS (Transrectal Ultrasound) image. The image acquisition system consists of an ultrasound transducer situated on a cradle directly attached to a rotational sensor. However, due to system tolerances, axis of probe does not align exactly with the designed axis of rotation resulting in artifacts in the 3D reconstructed ultrasound volume. We present a rigid registration based automatic probe calibration approach. The method uses a sequence of phantom images, each pair acquired at angular separation of 180 degrees and registers corresponding image pairs to compute the deviation from designed axis. A modified shadow removal algorithm is applied for preprocessing. An attribute vector is constructed from image intensity and a speckle-insensitive information-theoretic feature. We compare registration between the presented method and expert-corrected images in 16 prostate phantom scans. Images were acquired at multiple resolutions, and different misalignment settings from two ultrasound machines. Screenshots from 3D reconstruction are shown before and after misalignment correction. Registration parameters from automatic and manual correction were found to be in good agreement. Average absolute differences of translation and rotation between automatic and manual methods were 0.27 mm and 0.65 degree, respectively. The registration parameters also showed lower variability for automatic registration (pooled standard deviation σtranslation = 0.50 mm, σrotation = 0.52 degree) compared to the manual approach (pooled standard deviation σtranslation = 0.62 mm, σrotation = 0.78 degree).
Jongen, S; Vermeeren, A; van der Sluiszen, N N J J M; Schumacher, M B; Theunissen, E L; Kuypers, K P C; Vuurman, E F P M; Ramaekers, J G
2017-03-01
The on-the-road highway driving test is generally regarded as a gold standard for assessing drug-induced driving impairment. The primary outcome measure is the standard deviation of lateral position (SDLP), a measure of road tracking error or "weaving". The test has been calibrated for incremental doses of alcohol almost 30 years ago in order to define the impact of drug-induced impairment in terms of blood alcohol concentration (BAC) equivalents. Drug-induced changes in SDLP exceeding 2.4 cm have been evaluated as clinically relevant ever since. The present analysis was conducted to assess the robustness of the alcohol effect in a range of on-the-road driving studies which have been conducted since the initial alcohol calibration study. The present study pooled data of 182 participants from nine placebo-controlled crossover studies who performed the highway driving test, while their BAC was at or just below the legal limit for drivers (i.e., 0.5 g/L). Overall, mean SDLP increased with 2.5 cm (95% CI 2.0-2.9 cm). Equivalence testing showed that the clinical relevance criterion value of 2.4 cm fell well within the 95% CI in each individual study. Gender did not affect alcohol-induced changes in SDLP. These results demonstrate the robustness and validity of the clinical relevance criterion for SDLP as measured during on-the-road driving.
Donegan, Thomas M.
2018-01-01
Abstract Existing models for assigning species, subspecies, or no taxonomic rank to populations which are geographically separated from one another were analyzed. This was done by subjecting over 3,000 pairwise comparisons of vocal or biometric data based on birds to a variety of statistical tests that have been proposed as measures of differentiation. One current model which aims to test diagnosability (Isler et al. 1998) is highly conservative, applying a hard cut-off, which excludes from consideration differentiation below diagnosis. It also includes non-overlap as a requirement, a measure which penalizes increases to sample size. The “species scoring” model of Tobias et al. (2010) involves less drastic cut-offs, but unlike Isler et al. (1998), does not control adequately for sample size and attributes scores in many cases to differentiation which is not statistically significant. Four different models of assessing effect sizes were analyzed: using both pooled and unpooled standard deviations and controlling for sample size using t-distributions or omitting to do so. Pooled standard deviations produced more conservative effect sizes when uncontrolled for sample size but less conservative effect sizes when so controlled. Pooled models require assumptions to be made that are typically elusive or unsupported for taxonomic studies. Modifications to improving these frameworks are proposed, including: (i) introducing statistical significance as a gateway to attributing any weighting to findings of differentiation; (ii) abandoning non-overlap as a test; (iii) recalibrating Tobias et al. (2010) scores based on effect sizes controlled for sample size using t-distributions. A new universal method is proposed for measuring differentiation in taxonomy using continuous variables and a formula is proposed for ranking allopatric populations. This is based first on calculating effect sizes using unpooled standard deviations, controlled for sample size using t-distributions, for a series of different variables. All non-significant results are excluded by scoring them as zero. Distance between any two populations is calculated using Euclidian summation of non-zeroed effect size scores. If the score of an allopatric pair exceeds that of a related sympatric pair, then the allopatric population can be ranked as species and, if not, then at most subspecies rank should be assigned. A spreadsheet has been programmed and is being made available which allows this and other tests of differentiation and rank studied in this paper to be rapidly analyzed. PMID:29780266
Nagata, Yuki; Lennartz, Christian
2008-07-21
The atomistic simulation of charge transfer process for an amorphous Alq(3) system is reported. By employing electrostatic potential charges, we calculate site energies and find that the standard deviation of site energy distribution is about twice as large as predicted in previous research. The charge mobility is calculated via the Miller-Abrahams formalism and the master equation approach. We find that the wide site energy distribution governs Poole-Frenkel-type behavior of charge mobility against electric field, while the spatially correlated site energy is not a dominant mechanism of Poole-Frenkel behavior in the range from 2x10(5) to 1.4x10(6) V/cm. Also we reveal that randomly meshed connectivities are, in principle, required to account for the Poole-Frenkel mechanism. Charge carriers find a zigzag pathway at low electric field, while they find a straight pathway along electric field when a high electric field is applied. In the space-charge-limited current scheme, the charge-carrier density increases with electric field strength so that the nonlinear behavior of charge mobility is enhanced through the strong charge-carrier density dependence of charge mobility.
Labots, M Maaike; Laarakker, M C Marijke; Schetters, D Dustin; Arndt, S S Saskia; van Lith, H A Hein
2018-01-01
Guilloux et al. introduced: integrated behavioral z-scoring, a method for behavioral phenotyping of mice. Using this method multiple ethological variables can be combined to show an overall description of a certain behavioral dimension or motivational system. However, a problem may occur when the control group used for the calculation has a standard deviation of zero or when no control group is present to act as a reference group. In order to solve these problems, an improved procedure is suggested: taking the pooled data as reference. For this purpose a behavioral study with male mice from three inbred strains was carried out. The integrated behavioral z-scoring methodology was applied, thereby taking five different reference group options. The outcome regarding statistical significance and practical importance was compared. Significant effects and effect sizes were influenced by the choice of the reference group. In some cases it was impossible to use a certain population and condition, because one or more behavioral variables in question had a standard deviation of zero. Based on the improved method, male mice from the three inbred strains differed regarding activity and anxiety. Taking the method described by Guilloux et al. as basis, the present procedure improved the generalizability to all types of experimental designs in animal behavioral research. To solve the aforementioned problems and to avoid getting the diagnosis of data manipulation, the pooled data (combining the data from all experimental groups in a study) as reference option is recommended. Copyright © 2017 Elsevier B.V. All rights reserved.
Welding wire pressure sensor assembly
NASA Technical Reports Server (NTRS)
Morris, Timothy B. (Inventor); Milly, Peter F., Sr. (Inventor); White, J. Kevin (Inventor)
1994-01-01
The present invention relates to a device which is used to monitor the position of a filler wire relative to a base material being welded as the filler wire is added to a welding pool. The device is applicable to automated welding systems wherein nonconsumable electrode arc welding processes are utilized in conjunction with a filler wire which is added to a weld pool created by the electrode arc. The invention senses pressure deviations from a predetermined pressure between the filler wire and the base material, and provides electrical signals responsive to the deviations for actuating control mechanisms in an automatic welding apparatus so as to minimize the pressure deviation and to prevent disengagement of the contact between the filler wire and the base material.
Mellerup, Anders; Ståhl, Marie
2015-01-01
The aim of this article was to define the sampling level and method combination that captures antibiotic resistance at pig herd level utilizing qPCR antibiotic resistance gene quantification and culture-based quantification of antibiotic resistant coliform indicator bacteria. Fourteen qPCR assays for commonly detected antibiotic resistance genes were developed, and used to quantify antibiotic resistance genes in total DNA from swine fecal samples that were obtained using different sampling and pooling methods. In parallel, the number of antibiotic resistant coliform indicator bacteria was determined in the same swine fecal samples. The results showed that the qPCR assays were capable of detecting differences in antibiotic resistance levels in individual animals that the coliform bacteria colony forming units (CFU) could not. Also, the qPCR assays more accurately quantified antibiotic resistance genes when comparing individual sampling and pooling methods. qPCR on pooled samples was found to be a good representative for the general resistance level in a pig herd compared to the coliform CFU counts. It had significantly reduced relative standard deviations compared to coliform CFU counts in the same samples, and therefore differences in antibiotic resistance levels between samples were more readily detected. To our knowledge, this is the first study to describe sampling and pooling methods for qPCR quantification of antibiotic resistance genes in total DNA extracted from swine feces. PMID:26114765
Chung, Kyu Sung; Ha, Jeong Ku; Ra, Ho Jong; Kim, Jin Goo
2016-05-01
Although interest in medial meniscus posterior root tear (MMPRT) repair has increased, few case series have been reported. This meta-analysis aimed to examine the clinical and radiological effects of MMPRT repair by pooling pre- and post-operative data from case-series reports. A literature search was performed using MEDLINE/PubMed, the Cochrane Central Register of Controlled Trials, and EMBASE databases. Pre- and post-operative data were pooled to investigate the effects of MMPRT repair, including the Lysholm score improvement, meniscal extrusion (mm) reduction, progression of the Kellgren-Lawrence (K-L) grade, and cartilage status according to the Outerbridge classification. Treatment effects included paired standardized mean differences (difference in the pre- and post-operative mean outcomes divided by the standard deviation) for the Lysholm score and meniscal extrusion, as well as the pooled event rates of progression of K-L grade and cartilage status. As treatment effects, the Lysholm score increased by as much as 3.675 (P < 0.001), whereas meniscus extrusion was not reduced (n.s.). The overall pooled event rates of progression of K-L grade and cartilage status were 10.6 and 17.3 % (P < 0.001), respectively. According to the current literature, MMPRT repair resulted in significant improvements in the post-operative clinical subjective scores compared with the preoperative status. However, meniscus extrusion was not reduced. Considering the occurrence of progression of K-L grade and cartilage status, it did not prevent the progression of arthrosis completely. Based on these results, repair results in favourable outcomes for MMPRT. Meta-analysis, Level IV.
Tello, J. Sebastián; Myers, Jonathan A.; Macía, Manuel J.; Fuentes, Alfredo F.; Cayola, Leslie; Arellano, Gabriel; Loza, M. Isabel; Torrez, Vania; Cornejo, Maritza; Miranda, Tatiana B.; Jørgensen, Peter M.
2015-01-01
Despite long-standing interest in elevational-diversity gradients, little is known about the processes that cause changes in the compositional variation of communities (β-diversity) across elevations. Recent studies have suggested that β-diversity gradients are driven by variation in species pools, rather than by variation in the strength of local community assembly mechanisms such as dispersal limitation, environmental filtering, or local biotic interactions. However, tests of this hypothesis have been limited to very small spatial scales that limit inferences about how the relative importance of assembly mechanisms may change across spatial scales. Here, we test the hypothesis that scale-dependent community assembly mechanisms shape biogeographic β-diversity gradients using one of the most well-characterized elevational gradients of tropical plant diversity. Using an extensive dataset on woody plant distributions along a 4,000-m elevational gradient in the Bolivian Andes, we compared observed patterns of β-diversity to null-model expectations. β-deviations (standardized differences from null values) were used to measure the relative effects of local community assembly mechanisms after removing sampling effects caused by variation in species pools. To test for scale-dependency, we compared elevational gradients at two contrasting spatial scales that differed in the size of local assemblages and regions by at least an order of magnitude. Elevational gradients in β-diversity persisted after accounting for regional variation in species pools. Moreover, the elevational gradient in β-deviations changed with spatial scale. At small scales, local assembly mechanisms were detectable, but variation in species pools accounted for most of the elevational gradient in β-diversity. At large spatial scales, in contrast, local assembly mechanisms were a dominant force driving changes in β-diversity. In contrast to the hypothesis that variation in species pools alone drives β-diversity gradients, we show that local community assembly mechanisms contribute strongly to systematic changes in β-diversity across elevations. We conclude that scale-dependent variation in community assembly mechanisms underlies these iconic gradients in global biodiversity. PMID:25803846
Hemostatic profile and safety of pooled cryoprecipitate up to 120 hours after thawing.
Lokhandwala, Parvez M; O'Neal, Adrian; Patel, Eshan U; Brunker, Patricia A R; Gehrie, Eric A; Zheng, Gang; Kickler, Thomas S; Ness, Paul M; Tobian, Aaron A R
2018-05-01
AABB standards state that cryoprecipitate should be transfused within 4 to 6 hours after thawing. We evaluated coagulation factor levels and sterility of thawed pooled cryoprecipitate to assess whether shelf life can be safely extended. Donor cryoprecipitate pools (n = 20, 10 group A, 10 group O) were held at ambient temperature and sampled at 0, 4, 8, 24, 48, 72, 96, and 120 hours post-thawing for fibrinogen, Factor (F)VIII, and von Willebrand factor (vWF) levels. Samples were tested at 0 and 120 hours for sterility (BacT/Alert system). Sixty additional cryoprecipitate pools were evaluated after 72 hours. Longitudinal differences in component levels were determined by linear fixed-effects regression. Group O cryoprecipitate had significantly lower FVIII (p = 0.002) and vWF activity (p = 0.006) compared to group A at 0 hours, but were not statistically different in fibrinogen levels (p = 0.33). Fibrinogen levels were stable over 5 days: 501 ± 81 mg/unit (mean ± standard deviation) at 0 hours to 506 ± 102 mg/unit at 120 hours (p = 0.73). Similarly, there was no decline in vWF activity: 200 ± 53 IU/unit at 0 hours to 209 ± 57 IU/unit at 120 hours (p = 0.084). The FVIII activity significantly declined on average by 9.6 IU (95% confidence interval, 5.5-13.8) between 0 hours (111 ± 33 IU/unit) and 120 hours post-thaw (101 ± 33) (p < 0.001). No organisms were detected when cryoprecipitate pools were cultured at 0 hours, but at 120 hours Staphylococcus epidermidis was identified from one pool, potentially a contaminant introduced during repeated sampling. No cultures were positive among the 60 additional cryoprecipitate pools assessed at 72 hours. Extended cryoprecipitate storage at ambient temperature did not affect fibrinogen levels over 120 hours. Sterility of products held at ambient temperature for an extended period of time could be assessed by secondary culture. © 2018 AABB.
Temperature deviation index and elderly mortality in Japan.
Lim, Youn-Hee; Reid, Colleen E; Honda, Yasushi; Kim, Ho
2016-07-01
Few studies have examined how the precedence of abnormal temperatures in previous neighboring years affects the population's health. In the present study, we attempted to quantify the health effects of abnormal weather patterns by creating a metric called the temperature deviation index (TDI) and estimated the effects of TDI on mortality in Japan. We used data from 47 prefectures in Japan to compute the TDI on days between May and September from 1966 to 2010. The TDI is a summed product of an indicator of absence of high temperatures in the neighboring years, and more weights were assigned to the years closest to the current year. To estimate the TDI effects on elderly mortality, we used generalized linear modeling with a Poisson distribution after adjusting for apparent temperature, barometric pressure, day of the week, and time trend. For each prefecture, we estimated the TDI effects and pooled the estimates to yield a national average for 1991-2010 in Japan. The estimated effects of TDI in middle- or high-latitude prefectures were greater than in low-latitude prefectures. The estimated national average of TDI effects was a 0.5 % (95 % confidence intervals [CI], 0.1, 1.0) increase in elderly mortality per 1-unit (around 1 standard deviation) increase in the TDI. The significant pooled estimation of TDI effects was mainly due to the TDI effects on summer days with moderate temperature (25th-49th percentile, mean temperature 22.9 °C): a 1.9 % (95 % CI, 1.1, 2.6) increase in elderly mortality per 1-unit increase in the TDI. However, TDI effects were insignificant in other temperature ranges. These findings suggest that elderly deaths increased on moderate temperature days in the summer that differed substantially from days during that time window in the neighboring years. Therefore, not only high temperature itself but also temperature deviation compared to previous years could be considered to be a risk factor for elderly mortality in the summer.
Eisler, Diane L.; McNabb, Alan; Jorgensen, Danielle R.; Isaac-Renton, Judith L.
2004-01-01
We report on the use of West Nile virus Armored RNA as an internal positive control (IPC) for the extraction and reverse transcription-PCR (RT-PCR) of RNA extracted from field-collected mosquitoes and on a multiplex real-time Taqman RT-PCR to simultaneously detect the 3′ noncoding region of West Nile virus and the West Nile virus NS5-2 region comprising the IPC. Mosquito pools from the province of British Columbia, Canada (n = 635), were tested in duplicate and found to be negative for West Nile virus and positive for the IPC. Known West Nile virus-positive supernatants from mosquito pools from the provinces of Alberta and Manitoba were tested in duplicate and found to be positive for both regions of the West Nile virus genome. The mean cycle threshold (Ct) value for the IPC in batch extraction controls ± 2 standard deviations was found to be 36.43 ± 1.78 cycles. IPCs of 98.4% (624) of West Nile virus-negative pools fell within this range, indicating the reproducibility of RNA extraction and RT-PCR for pools varying in mosquito genus and number. A comparison of mosquito pool genera revealed no significant genus effect on the Ct value of the IPC. The incorporation of West Nile virus Armored RNA as an IPC allows monitoring of RNA extraction and RT-PCR and detection of false-negative results due to failures in these processes or to PCR inhibition, respectively. PMID:14766868
Sun, Maxine; Cole, Alexander P; Hanna, Nawar; Mucci, Lorelei A; Berry, Donna L; Basaria, Shehzad; Ahern, David K; Kibel, Adam S; Choueiri, Toni K; Trinh, Quoc-Dien
2018-06-01
Use of androgen deprivation therapy may increase the risk of cognitive impairment in men with prostate cancer. We performed a systematic review of the risk of overall cognitive impairment as an outcome in men receiving androgen deprivation therapy for prostate cancer. Studies were identified through PubMed®, MEDLINE®, PsycINFO®, Cochrane Library and Web of Knowledge/Science™. Articles were included if they 1) were published in English, 2) had subjects treated for prostate cancer with androgen deprivation therapy, 3) incorporated longitudinal comparisons and 4) used control groups. In addition, prospective studies were required to assess an established cognitive related end point using International Cognition and Cancer Task Force criteria defining impaired cognitive performance as scoring 1.5 or more standard deviations below published norms on 2 or more tests, or scoring 2.0 or more standard deviations below published norms on at least 1 test. The effect of androgen deprivation therapy on cognitive impairment was pooled using a random effects model. Of 221 abstracts 26 were selected for full text review, and 2 prospective and 4 retrospective studies were analyzed. Androgen deprivation therapy was not associated with overall cognitive impairment when the prospective cohort studies were pooled (OR 1.57, 95% CI 0.50 to 4.92, p = 0.44) with significant heterogeneity between estimates (I 2 = 83%). In retrospective data the relative risk of any cognitive impairment, including senile dementia and Alzheimer disease, was increased in men receiving androgen deprivation therapy, although the difference was not statistically significant (HR 1.28, 95% CI 0.93 to 1.76, p = 0.13) with moderate heterogeneity between estimates (I 2 = 67%). Analyses between overall cognitive impairment and use of androgen deprivation therapy defined according to International Cognition and Cancer Task Force criteria in a pooled analysis were inconclusive. In retrospective cohort studies the risk of overall cognitive impairment after androgen deprivation therapy was not significant. Better prospective studies need to be designed for the assessment of this end point. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
High-resolution 40Ar 39Ar chronology of Oligocene volcanic rocks, San Juan Mountains, Colorado
Lanphere, M.A.
1988-01-01
The central San Juan caldera complex consists of seven calderas from which eight major ash-flow tuffs were erupted during a period of intense volcanic activity that lasted for approximately 2 m.y. about 26-28 Ma. The analytical precision of conventional K-Ar dating in this time interval is not sufficient to unambiguously resolve this complex history. However, 40Ar 39Ar incremental-heating experiments provide data for a high-resolution chronology that is consistent with stratigraphie relations. Weighted-mean age-spectrum plateau ages of biotite and sanidine are the most precise with standard deviations ranging from 0.08 to 0.21 m.y. The pooled estimate of standard deviation for the plateau ages of 12 minerals is about 0.5 percent or about 125,000 to 135,000 years. Age measurements on coexisting minerals from one tuff and on two samples of each of two other tuffs indicate that a precision in the age of a tuff of better than 100,000 years can be achieved at 27 Ma. New data indicate that the San Luis caldera is the youngest caldera in the central complex, not the Creede caldera as previously thought. ?? 1988.
Nitrogen isotopic analyses by isotope-ratio-monitoring gas chromatography/mass spectrometry
NASA Technical Reports Server (NTRS)
Merritt, D. A.; Hayes, J. M.
1994-01-01
Amino acids containing natural-abundance levels of 15N were derivatized and analyzed isotopically using a technique in which individual compounds are separated by gas chromatography, combusted on-line, and the product stream sent directly to an isotope-ratio mass spectrometer. For samples of N2 gas, standard deviations of ratio measurement were better than 0.1% (Units for delta are parts per thousand or per million (%).) for samples larger than 400 pmol and better than 0.5% for samples larger than 25 pmol (0.1% 15N is equivalent to 0.00004 atom % 15N). Results duplicated those of conventional, batchwise analyses to within 0.05%. For combustion of organic compounds yielding CO2/N2 ratios between 14 and 28, in particular for N-acetyl n-propyl derivatives of amino acids, delta values were within 0.25% of results obtained using conventional techniques and standard deviations were better than 0.35%. Pooled data for measurements of all amino acids produced an accuracy and precision of 0.04 and 0.23%, respectively, when 2 nmol of each amino acid was injected on column and 20% of the stream of combustion products was delivered to the mass spectrometer.
Gradient Magnitude Similarity Deviation: A Highly Efficient Perceptual Image Quality Index.
Xue, Wufeng; Zhang, Lei; Mou, Xuanqin; Bovik, Alan C
2014-02-01
It is an important task to faithfully evaluate the perceptual quality of output images in many applications, such as image compression, image restoration, and multimedia streaming. A good image quality assessment (IQA) model should not only deliver high quality prediction accuracy, but also be computationally efficient. The efficiency of IQA metrics is becoming particularly important due to the increasing proliferation of high-volume visual data in high-speed networks. We present a new effective and efficient IQA model, called gradient magnitude similarity deviation (GMSD). The image gradients are sensitive to image distortions, while different local structures in a distorted image suffer different degrees of degradations. This motivates us to explore the use of global variation of gradient based local quality map for overall image quality prediction. We find that the pixel-wise gradient magnitude similarity (GMS) between the reference and distorted images combined with a novel pooling strategy-the standard deviation of the GMS map-can predict accurately perceptual image quality. The resulting GMSD algorithm is much faster than most state-of-the-art IQA methods, and delivers highly competitive prediction accuracy. MATLAB source code of GMSD can be downloaded at http://www4.comp.polyu.edu.hk/~cslzhang/IQA/GMSD/GMSD.htm.
Abraha, Iosief; Cherubini, Antonio; Cozzolino, Francesco; De Florio, Rita; Luchetta, Maria Laura; Rimland, Joseph M; Folletti, Ilenia; Marchesi, Mauro; Germani, Antonella; Orso, Massimiliano; Eusebi, Paolo; Montedori, Alessandro
2015-05-27
To examine whether deviation from the standard intention to treat analysis has an influence on treatment effect estimates of randomised trials. Meta-epidemiological study. Medline, via PubMed, searched between 2006 and 2010; 43 systematic reviews of interventions and 310 randomised trials were included. From each year searched, random selection of 5% of intervention reviews with a meta-analysis that included at least one trial that deviated from the standard intention to treat approach. Basic characteristics of the systematic reviews and randomised trials were extracted. Information on the reporting of intention to treat analysis, outcome data, risk of bias items, post-randomisation exclusions, and funding were extracted from each trial. Trials were classified as: ITT (reporting the standard intention to treat approach), mITT (reporting a deviation from the standard approach), and no ITT (reporting no approach). Within each meta-analysis, treatment effects were compared between mITT and ITT trials, and between mITT and no ITT trials. The ratio of odds ratios was calculated (value <1 indicated larger treatment effects in mITT trials than in other trial categories). 50 meta-analyses and 322 comparisons of randomised trials (from 84 ITT trials, 118 mITT trials, and 108 no ITT trials; 12 trials contributed twice to the analysis) were examined. Compared with ITT trials, mITT trials showed a larger intervention effect (pooled ratio of odds ratios 0.83 (95% confidence interval 0.71 to 0.96), P=0.01; between meta-analyses variance τ(2)=0.13). Adjustments for sample size, type of centre, funding, items of risk of bias, post-randomisation exclusions, and variance of log odds ratio yielded consistent results (0.80 (0.69 to 0.94), P=0.005; τ(2)=0.08). After exclusion of five influential studies, results remained consistent (0.85 (0.75 to 0.98); τ(2)=0.08). The comparison between mITT trials and no ITT trials showed no statistical difference between the two groups (adjusted ratio of odds ratios 0.92 (0.70 to 1.23); τ(2)=0.57). Trials that deviated from the intention to treat analysis showed larger intervention effects than trials that reported the standard approach. Where an intention to treat analysis is impossible to perform, authors should clearly report who is included in the analysis and attempt to perform multiple imputations. © Abraha et al 2015.
Resistance Training Increases the Variability of Strength Test Scores
2009-06-08
standard deviations for pretest and posttest strength measurements. This information was recorded for every strength test used in a total of 377 samples...significant if the posttest standard deviation consistently was larger than the pretest standard deviation. This condition could be satisfied even if...the difference in the standard deviations was small. For example, the posttest standard deviation might be 1% larger than the pretest standard
Quan, Hui; Zhang, Ji
2003-09-15
Analyses of study variables are frequently based on log transformations. To calculate the power for detecting the between-treatment difference in the log scale, we need an estimate of the standard deviation of the log-transformed variable. However, in many situations a literature search only provides the arithmetic means and the corresponding standard deviations. Without individual log-transformed data to directly calculate the sample standard deviation, we need alternative methods to estimate it. This paper presents methods for estimating and constructing confidence intervals for the standard deviation of a log-transformed variable given the mean and standard deviation of the untransformed variable. It also presents methods for estimating the standard deviation of change from baseline in the log scale given the means and standard deviations of the untransformed baseline value, on-treatment value and change from baseline. Simulations and examples are provided to assess the performance of these estimates. Copyright 2003 John Wiley & Sons, Ltd.
7 CFR 400.204 - Notification of deviation from standards.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from standards. 400.204... Contract-Standards for Approval § 400.204 Notification of deviation from standards. A Contractor shall advise the Corporation immediately if the Contractor deviates from the requirements of these standards...
Deng, Xi; Schröder, Simone; Redweik, Sabine; Wätzig, Hermann
2011-06-01
Gel electrophoresis (GE) is a very common analytical technique for proteome research and protein analysis. Despite being developed decades ago, there is still a considerable need to improve its precision. Using the fluorescence of Colloidal Coomassie Blue -stained proteins in near-infrared (NIR), the major error source caused by the unpredictable background staining is strongly reduced. This result was generalized for various types of detectors. Since GE is a multi-step procedure, standardization of every single step is required. After detailed analysis of all steps, the staining and destaining were identified as the major source of the remaining variation. By employing standardized protocols, pooled percent relative standard deviations of 1.2-3.1% for band intensities were achieved for one-dimensional separations in repetitive experiments. The analysis of variance suggests that the same batch of staining solution should be used for gels of one experimental series to minimize day-to-day variation and to obtain high precision. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The Standard Deviation of Launch Vehicle Environments
NASA Technical Reports Server (NTRS)
Yunis, Isam
2005-01-01
Statistical analysis is used in the development of the launch vehicle environments of acoustics, vibrations, and shock. The standard deviation of these environments is critical to accurate statistical extrema. However, often very little data exists to define the standard deviation and it is better to use a typical standard deviation than one derived from a few measurements. This paper uses Space Shuttle and expendable launch vehicle flight data to define a typical standard deviation for acoustics and vibrations. The results suggest that 3dB is a conservative and reasonable standard deviation for the source environment and the payload environment.
Hager, Stephen W.
1994-01-01
Particulate matter was collected at Rio Vista, California, in two study periods; the first, from January 3 to May 26, 1983; the second from October 31, 1983 to November 29, 1984. Concentrations of suspended particulate matter were measured gravimetrically on silver membrane filters. The pooled standard deviation on replicated samples was 1.4 mg/L, giving a coefficient of variation of 5.7 percent. Concentrations of particulate carbon and nitrogen were measured during a Perkin-Elmer model 240C elemental analyzer to combust material collected on glass fiber filters. Refrigeration of samples prior to filtration was shown to be a likely influence on precision of duplicate analyses. Median deviations between duplicates for carbon were 5.4 percent during the first study period and 8.9 percent during the second. For nitrogen, median deviations were 4.9 percent and 7.2 percent, respectively. This report presents the data for concentrations of suspended particulate material, the duplicate analyses for particulate carbon and nitrogen, and the volumes of sample filtered for the particulate carbon and nitrogen analyses for both studies. Not all samples collected during the second study have been analyzed for particulate carbon and nitrogen.
Scaling up the 454 Titanium Library Construction and Pooling of Barcoded Libraries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phung, Wilson; Hack, Christopher; Shapiro, Harris
2009-03-23
We have been developing a high throughput 454 library construction process at the Joint Genome Institute to meet the needs of de novo sequencing a large number of microbial and eukaryote genomes, EST, and metagenome projects. We have been focusing efforts in three areas: (1) modifying the current process to allow the construction of 454 standard libraries on a 96-well format; (2) developing a robotic platform to perform the 454 library construction; and (3) designing molecular barcodes to allow pooling and sorting of many different samples. In the development of a high throughput process to scale up the number ofmore » libraries by adapting the process to a 96-well plate format, the key process change involves the replacement of gel electrophoresis for size selection with Solid Phase Reversible Immobilization (SPRI) beads. Although the standard deviation of the insert sizes increases, the overall quality sequence and distribution of the reads in the genome has not changed. The manual process of constructing 454 shotgun libraries on 96-well plates is a time-consuming, labor-intensive, and ergonomically hazardous process; we have been experimenting to program a BioMek robot to perform the library construction. This will not only enable library construction to be completed in a single day, but will also minimize any ergonomic risk. In addition, we have implemented a set of molecular barcodes (AKA Multiple Identifiers or MID) and a pooling process that allows us to sequence many targets simultaneously. Here we will present the testing of pooling a set of selected fosmids derived from the endomycorrhizal fungus Glomus intraradices. By combining the robotic library construction process and the use of molecular barcodes, it is now possible to sequence hundreds of fosmids that represent a minimal tiling path of this genome. Here we present the progress and the challenges of developing these scaled-up processes.« less
Improving student learning via mobile phone video content: Evidence from the BridgeIT India project
NASA Astrophysics Data System (ADS)
Wennersten, Matthew; Quraishy, Zubeeda Banu; Velamuri, Malathi
2015-08-01
Past efforts invested in computer-based education technology interventions have generated little evidence of affordable success at scale. This paper presents the results of a mobile phone-based intervention conducted in the Indian states of Andhra Pradesh and Tamil Nadu in 2012-13. The BridgeIT project provided a pool of audio-visual learning materials organised in accordance with a system of syllabi pacing charts. Teachers of Standard 5 and 6 English and Science classes were notified of the availability of new videos via text messages (SMS), which they downloaded onto their phones using an open-source application and showed, with suggested activities, to students on a TV screen using a TV-out cable. In their evaluation of this project, the authors of this paper found that the test scores of children who experienced the intervention improved by 0.36 standard deviations in English and 0.98 standard deviations in Science in Andhra Pradesh, relative to students in similar classrooms who did not experience the intervention. Differences between treatment and control schools in Tamil Nadu were less marked. The intervention was also cost-effective, relative to other computer-based interventions. Based on these results, the authors argue that is possible to use mobile phones to produce a strong positive and statistically significant effect in terms of teaching and learning quality across a large number of classrooms in India at a lower cost per student than past computer-based interventions.
7 CFR 400.174 - Notification of deviation from financial standards.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from financial standards... Agreement-Standards for Approval; Regulations for the 1997 and Subsequent Reinsurance Years § 400.174 Notification of deviation from financial standards. An insurer must immediately advise FCIC if it deviates from...
Degrees of Freedom for Allan Deviation Estimates of Multiple Clocks
2016-04-01
Allan deviation . Allan deviation will be represented by σ and standard deviation will be represented by δ. In practice, when the Allan deviation of a...the Allan deviation of standard noise types. Once the number of degrees of freedom is known, an approximate confidence interval can be assigned by...measurement errors from paired difference data. We extend this approach by using the Allan deviation to estimate the error in a frequency standard
NASA Astrophysics Data System (ADS)
Briggs, M.; Lautz, L. K.; McKenzie, J. M.
2010-12-01
Small dams enhance hyporheic interaction by creating punctuated head differentials along streams, thereby affecting redox conditions and nutrient cycling in the streambed. As beaver populations return, they create dams that alter hyporheic flowpaths locally, an effect which may integrate at the reach scale to produce a net hydrological and ecological functional change. Streambed heterogeneity around beaver dams combines with varied morphology, head differentials and stream velocities to create patterns of hyporheic seepage flux that vary in both space and time. Heat has been used as a groundwater tracer for many years, but it’s dependence on spatially disperse point measurements has only recently been resolved by the development of Distributed Temperature Sensing (DTS) fiber-optic technology. Modified applications of DTS include wrapping the fiber around a mandrel to increase spatial resolution dramatically. Wrapped configurations can be installed vertically in the streambed to provide data for heat transport modeling of vertical hyporheic flux. The vertically continuous dataset generated with DTS may be more informative regarding subsurface heterogeneity than more commonly used spatially discrete thermocouples. We installed a total of nine wrapped DTS rods with 1.4 cm vertical spatial resolution above two beaver dams in Cherry Creek, a tributary of the Little Popo Agie River in Lander, Wyoming, USA. Data was collected over 20 min periods in dual-ended mode continuously for one month (10-Jul to 10-Aug 2010) during baseflow recession, as discharge dropped from 384 Ls-1 to 211 Ls-1. The temperature rods were installed to at least 0.75 m depth within bed sediments at varied distances upstream of the dams in diverse stream morphological units, which ranged from gravel bars to clay lined pools. Diurnal fluctuations in stream temperature were generally between 4.5 and 5.5 oC in amplitude, imparting a strong potential signal for propagation into the bed due to advective hyporheic flux. In many locations monthly temperature standard deviations at the 10 cm depth were larger than that of the overlying stream water, indicating direct heating of the streambed by solar radiation was an important process, even in that high velocity system. The high-resolution temperature records revealed local heterogeneity in the streambed at each rod and indicated the largest hyporheic flux was within gravel bars close to the dams. The smallest flux was through a gravel bar farther upstream of the dam, and through the deepest portions of pools closer to the dam. High flux regions had monthly temperature standard deviations close to that of the stream (1.5 oC) at shallow depths, while shallow sediments in pools had much more muted temperature oscillations. At 0.5 m depth, all rods had similar, smaller temperature standard deviations, ranging from 0.64-0.80 oC. The extensive and spatially continuous data set generated using DTS allowed us to determine hyporheic flux patterns for virtually any depth and time along the high-resolution temperature rods, a crucial step for understanding transient patterns in biogeochemical processing around beaver dams.
1 CFR 21.14 - Deviations from standard organization of the Code of Federal Regulations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 1 General Provisions 1 2010-01-01 2010-01-01 false Deviations from standard organization of the... CODIFICATION General Numbering § 21.14 Deviations from standard organization of the Code of Federal Regulations. (a) Any deviation from standard Code of Federal Regulations designations must be approved in advance...
Upgraded FAA Airfield Capacity Model. Volume 1. Supplemental User’s Guide
1981-02-01
SIGMAR (P4.0) cc 1-4 -standard deviation, in seconds, of arrival runway occupancy time (R.O.T.). SIGMAA (F4.0) cc 5-8 -standard deviation, in seconds...iI SI GMAC - The standard deviation of the time from departure clearance to start of roll. SIGMAR - The standard deviation of the arrival runway
A Visual Model for the Variance and Standard Deviation
ERIC Educational Resources Information Center
Orris, J. B.
2011-01-01
This paper shows how the variance and standard deviation can be represented graphically by looking at each squared deviation as a graphical object--in particular, as a square. A series of displays show how the standard deviation is the size of the average square.
Miled, Rabeb Bennour; Guillier, Laurent; Neves, Sandra; Augustin, Jean-Christophe; Colin, Pierre; Besse, Nathalie Gnanou
2011-06-01
Cells of six strains of Cronobacter were subjected to dry stress and stored for 2.5 months at ambient temperature. The individual cell lag time distributions of recovered cells were characterized at 25 °C and 37 °C in non-selective broth. The individual cell lag times were deduced from the times taken by cultures from individual cells to reach an optical density threshold. In parallel, growth curves for each strain at high contamination levels were determined in the same growth conditions. In general, the extreme value type II distribution with a shape parameter fixed to 5 (EVIIb) was the most effective at describing the 12 observed distributions of individual cell lag times. Recently, a model for characterizing individual cell lag time distribution from population growth parameters was developed for other food-borne pathogenic bacteria such as Listeria monocytogenes. We confirmed this model's applicability to Cronobacter by comparing the mean and the standard deviation of individual cell lag times to populational lag times observed with high initial concentration experiments. We also validated the model in realistic conditions by studying growth in powdered infant formula decimally diluted in Buffered Peptone Water, which represents the first enrichment step of the standard detection method for Cronobacter. Individual lag times and the pooling of samples significantly affect detection performances. Copyright © 2010 Elsevier Ltd. All rights reserved.
Basic life support: evaluation of learning using simulation and immediate feedback devices1.
Tobase, Lucia; Peres, Heloisa Helena Ciqueto; Tomazini, Edenir Aparecida Sartorelli; Teodoro, Simone Valentim; Ramos, Meire Bruna; Polastri, Thatiane Facholi
2017-10-30
to evaluate students' learning in an online course on basic life support with immediate feedback devices, during a simulation of care during cardiorespiratory arrest. a quasi-experimental study, using a before-and-after design. An online course on basic life support was developed and administered to participants, as an educational intervention. Theoretical learning was evaluated by means of a pre- and post-test and, to verify the practice, simulation with immediate feedback devices was used. there were 62 participants, 87% female, 90% in the first and second year of college, with a mean age of 21.47 (standard deviation 2.39). With a 95% confidence level, the mean scores in the pre-test were 6.4 (standard deviation 1.61), and 9.3 in the post-test (standard deviation 0.82, p <0.001); in practice, 9.1 (standard deviation 0.95) with performance equivalent to basic cardiopulmonary resuscitation, according to the feedback device; 43.7 (standard deviation 26.86) mean duration of the compression cycle by second of 20.5 (standard deviation 9.47); number of compressions 167.2 (standard deviation 57.06); depth of compressions of 48.1 millimeter (standard deviation 10.49); volume of ventilation 742.7 (standard deviation 301.12); flow fraction percentage of 40.3 (standard deviation 10.03). the online course contributed to learning of basic life support. In view of the need for technological innovations in teaching and systematization of cardiopulmonary resuscitation, simulation and feedback devices are resources that favor learning and performance awareness in performing the maneuvers.
Use of intertidal areas by shrimps (Decapoda) in a Brazilian Amazon estuary.
Sampaio, Hebert A; Martinelli-Lemos, Jussara M
2014-03-01
The present work investigated the occupation and the correlation of the shrimp abundance in relation to environmental variables in different habitats (mangroves, salt marshes and rocky outcrops) in an Amazon estuary. The collections were made in August and November 2009, at low syzygy tide on Areuá Beach, situated in the Extractive Reserve of Mãe Grande de Curuçá, Pará, Brazil totaling 20 pools. In each environment, we recorded the physical-chemical factors (pH, salinity, and temperature) and measured the area (m2) and volume (m3) of every pool through bathymetry. The average pH, salinity, temperature, area and volume of tide pools were 8.75 (± 0.8 standard deviation), 35.45 (± 3), 29.49 °C (± 2.32), 27.41 m2 (± 41.18), and 5.19 m3 (± 8.01), respectively. We caught a total of 4,871 shrimps, distributed in three families and four species: Farfantepenaeus subtilis (98.36%) (marine) followed by Alpheus pontederiae (0.76%) (estuarine), Macrobrachium surinamicum (0.45%) and Macrobrachium amazonicum (0.43%) predominantly freshwater. The species F. subtilis and A. pontederiae occurred in the three habitats, whereas M. surinamicum occurred in salt marsh and rocky outcrop and M. amazonicum only in marisma. Temperature and pH were the most important environmental descriptors that significantly affected the density and biomass of shrimps.
Sleep Duration and Patterns in Chinese Older Adults: a Comprehensive Meta-analysis.
Lu, Li; Wang, Shi-Bin; Rao, Wen-Wang; Ungvari, Gabor S; Ng, Chee H; Chiu, Helen F K; Zhang, Juan; Kou, Changgui; Jia, Fu-Jun; Xiang, Yu-Tao
2017-01-01
This meta-analysis examined the mean sleep duration and patterns in Chinese older adult population. A literature search was systematically conducted covering major English (PubMed, Embase and PsycINFO) and Chinese (Chinese National Knowledge Infrastructure (CNKI), WanFang and SinoMed) databases. Data in studies with the mean and standard deviation of sleep duration and/or the proportion of short and long sleep durations in Chinese older adults were extracted and pooled using random-effects models. Subgroup analyses were conducted according to gender, region, area, survey time and sample size. A total of 36 studies with 150,616 subjects were included for analyses. The pooled mean sleep duration of 21 studies with available data was 6.82 hours/day (95% CI: 6.59-7.05 hours/day). The estimated proportions of sleep duration <5 hours/day, <6 hours/day, <7 hours/day were 18.8% (95% CI: 1.7%-35.9%), 26.7% (95% CI: 19.7%-33.7%) and 42.3% (95% CI: 34.8%-49.8%), respectively. The pooled proportions for long sleepers were 22.6% (95% CI: 13.9%-31.4%) (>8 hours/day) and 17.6% (95% CI: 12.4%-22.9%) (>9 hours/day). Given the adverse effects of unhealthy sleep patterns, health professionals should pay more attention to sleep patterns in this population in China.
Production of NOx and other precursors of ozone formation in the Uinta Basin
NASA Astrophysics Data System (ADS)
Smith, E.; Lyman, S. N.; Martin, R. S.; Anderson, R.
2012-12-01
The Uinta Basin, located in northeastern Utah, sometimes experiences ozone mixing ratios greater than the EPA NAAQS during specific meteorological conditions that include a combination of snow cover and inversion. We monitored ozone and some of its precursors, including NO, NO2, NOx (NO + NO2), and NOy (sum of reactive nitrogen species), at two sites (Roosevelt and Horse Pool). The Roosevelt site is in a city of about 6,000 people, and the Horse Pool site is in an area of intensive oil and gas production. In February and March 2012, NO, NO2, and NOy mixing ratios were 0.5 ± 0.8, 5.2 ± 2.6, and 6.5 ± 3.9 ppb at Roosevelt and 0 ± 1.3, 2.8 ± 2.7, and 4.1 ± 4.4 ppb at Horse Pool, respectively (mean ± standard deviation). NO, NO2, and NOx were measured at 7 other sites around the Basin by other entities. The spatial and temporal patterns in NOx and NOy indicate the dominance of local source influences on observed mixing ratios. NOx at urban sites and in oil and gas production areas appeared strongly influenced by traffic patterns. At some sites, wind direction analysis and air trajectory analysis indicated that areas of oil and gas production are significant sources of NOx, though pinpointing individual NOx sources proved difficult.
1968 Listing of Swimming Pool Equipment.
ERIC Educational Resources Information Center
National Sanitation Foundation, Ann Arbor, MI. Testing Lab.
An up-to-date listing of swimming pool equipment including--(1) companies authorized to display the National Sanitation Foundation seal of approval, (2) equipment listed as meeting NSF swimming pool equipment standards relating to diatomite type filters, (3) equipment listed as meeting NSF swimming pool equipment standard relating to sand type…
Impact of traffic oscillations on freeway crash occurrences.
Zheng, Zuduo; Ahn, Soyoung; Monsere, Christopher M
2010-03-01
Traffic oscillations are typical features of congested traffic flow that are characterized by recurring decelerations followed by accelerations (stop-and-go driving). The negative environmental impacts of these oscillations are widely accepted, but their impact on traffic safety has been debated. This paper describes the impact of freeway traffic oscillations on traffic safety. This study employs a matched case-control design using high-resolution traffic and crash data from a freeway segment. Traffic conditions prior to each crash were taken as cases, while traffic conditions during the same periods on days without crashes were taken as controls. These were also matched by presence of congestion, geometry and weather. A total of 82 cases and about 80,000 candidate controls were extracted from more than three years of data from 2004 to 2007. Conditional logistic regression models were developed based on the case-control samples. To verify consistency in the results, 20 different sets of controls were randomly extracted from the candidate pool for varying control-case ratios. The results reveal that the standard deviation of speed (thus, oscillations) is a significant variable, with an average odds ratio of about 1.08. This implies that the likelihood of a (rear-end) crash increases by about 8% with an additional unit increase in the standard deviation of speed. The average traffic states prior to crashes were less significant than the speed variations in congestion. Published by Elsevier Ltd.
Shared Components of Rhythm Generation for Locomotion and Scratching Exist Prior to Motoneurons
Hao, Zhao-Zhe; Berkowitz, Ari
2017-01-01
Does the spinal cord use a single network to generate locomotor and scratching rhythms or two separate networks? Previous research showed that simultaneous swim and scratch stimulation (“dual stimulation”) in immobilized, spinal turtles evokes a single rhythm in hindlimb motor nerves with a frequency often greater than during swim stimulation alone or scratch stimulation alone. This suggests that the signals that trigger swimming and scratching converge and are integrated within the spinal cord. However, these results could not determine whether the integration occurs in motoneurons themselves or earlier, in spinal interneurons. Here, we recorded intracellularly from hindlimb motoneurons during dual stimulation. Motoneuron membrane potentials displayed regular oscillations at a higher frequency during dual stimulation than during swim or scratch stimulation alone. In contrast, arithmetic addition of the oscillations during swimming alone and scratching alone with various delays always generated irregular oscillations. Also, the standard deviation of the phase-normalized membrane potential during dual stimulation was similar to those during swimming or scratching alone. In contrast, the standard deviation was greater when pooling cycles of swimming alone and scratching alone for two of the three forms of scratching. This shows that dual stimulation generates a single rhythm prior to motoneurons. Thus, either swimming and scratching largely share a rhythm generator or the two rhythms are integrated into one rhythm by strong interactions among interneurons. PMID:28848402
ERIC Educational Resources Information Center
National Sanitation Foundation, Ann Arbor, MI.
THE NATIONAL SANITATION FOUNDATION STANDARD ON SWIMMING POOL EQUIPMENT CONCERNS ITSELF WITH THE SUCCESSFUL APPLICATION OF SURFACE SKIMMERS TO SWIMMING POOLS. THE MINIMUM DESIGN AND CONSTRUCTION REQUIREMENTS ESTABLISHED BY THIS STANDARD ARE SET FORTH TO PROVIDE A MEANS OF EVALUATING THE OVERALL CONSTRUCTION AND EFFECTIVENESS OF THE UNIT. ADDITIONAL…
Kessler, Thomas; Neumann, Jörg; Mummendey, Amélie; Berthold, Anne; Schubert, Thomas; Waldzus, Sven
2010-09-01
To explain the determinants of negative behavior toward deviants (e.g., punishment), this article examines how people evaluate others on the basis of two types of standards: minimal and maximal. Minimal standards focus on an absolute cutoff point for appropriate behavior; accordingly, the evaluation of others varies dichotomously between acceptable or unacceptable. Maximal standards focus on the degree of deviation from that standard; accordingly, the evaluation of others varies gradually from positive to less positive. This framework leads to the prediction that violation of minimal standards should elicit punishment regardless of the degree of deviation, whereas punishment in response to violations of maximal standards should depend on the degree of deviation. Four studies assessed or manipulated the type of standard and degree of deviation displayed by a target. Results consistently showed the expected interaction between type of standard (minimal and maximal) and degree of deviation on punishment behavior.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 1: January
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of January. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Mean density standard deviation (all for 13 levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Comparing Standard Deviation Effects across Contexts
ERIC Educational Resources Information Center
Ost, Ben; Gangopadhyaya, Anuj; Schiman, Jeffrey C.
2017-01-01
Studies using tests scores as the dependent variable often report point estimates in student standard deviation units. We note that a standard deviation is not a standard unit of measurement since the distribution of test scores can vary across contexts. As such, researchers should be cautious when interpreting differences in the numerical size of…
Mancia, G; Ferrari, A; Gregorini, L; Parati, G; Pomidossi, G; Bertinieri, G; Grassi, G; Zanchetti, A
1980-12-01
1. Intra-arterial blood pressure and heart rate were recorded for 24 h in ambulant hospitalized patients of variable age who had normal blood pressure or essential hypertension. Mean 24 h values, standard deviations and variation coefficient were obtained as the averages of values separately analysed for 48 consecutive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation aations and variation coefficient were obtained as the averages of values separately analysed for 48 consecurive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for heart rate were smaller. 3. In hypertensive subjects standard deviation for mean arterial pressure was greater than in normotensive subjects of similar ages, but this was not the case for variation coefficient, which was slightly smaller in the former than in the latter group. Normotensive and hypertensive subjects showed no difference in standard deviation and variation coefficient for heart rate. 4. In both normotensive and hypertensive subjects standard deviation and even more so variation coefficient were slightly or not related to arterial baroreflex sensitivity as measured by various methods (phenylephrine, neck suction etc.). 5. It is concluded that blood pressure variability increases and heart rate variability decreases with age, but that changes in variability are not so obvious in hypertension. Also, differences in variability among subjects are only marginally explained by differences in baroreflex function.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 7: July
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of July. Included are global analyses of: (1) Mean temperature/standard deviation; (2) Mean geopotential height/standard deviation; (3) Mean density/standard deviation; (4) Height and vector standard deviation (all at 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation at levels 1000 through 30 mb; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 10: October
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of October. Included are global analyses of: (1) Mean temperature/standard deviation; (2) Mean geopotential height/standard deviation; (3) Mean density/standard deviation; (4) Height and vector standard deviation (all at 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point/standard deviation at levels 1000 through 30 mb; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 3: March
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-11-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of March. Included are global analyses of: (1) Mean Temperature Standard Deviation; (2) Mean Geopotential Height Standard Deviation; (3) Mean Density Standard Deviation; (4) Height and Vector Standard Deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean Dew Point Standard Deviation for levels 1000 through 30 mb; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 2: February
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-09-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of February. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Height and vector standard deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 4: April
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of April. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Height and vector standard deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
DeSantis, Michael C; DeCenzo, Shawn H; Li, Je-Luen; Wang, Y M
2010-03-29
Standard deviation measurements of intensity profiles of stationary single fluorescent molecules are useful for studying axial localization, molecular orientation, and a fluorescence imaging system's spatial resolution. Here we report on the analysis of the precision of standard deviation measurements of intensity profiles of single fluorescent molecules imaged using an EMCCD camera.We have developed an analytical expression for the standard deviation measurement error of a single image which is a function of the total number of detected photons, the background photon noise, and the camera pixel size. The theoretical results agree well with the experimental, simulation, and numerical integration results. Using this expression, we show that single-molecule standard deviation measurements offer nanometer precision for a large range of experimental parameters.
Milne, Elizabeth; Greenop, Kathryn R.; Metayer, Catherine; Schüz, Joachim; Petridou, Eleni; Pombo-de-Oliveira, Maria S.; Infante-Rivard, Claire; Roman, Eve; Dockerty, John D.; Spector, Logan G.; Koifman, Sérgio; Orsi, Laurent; Rudant, Jérémie; Dessypris, Nick; Simpson, Jill; Lightfoot, Tracy; Kaatsch, Peter; Baka, Margarita; Faro, Alessandra; Armstrong, Bruce K.; Clavel, Jacqueline; Buffler, Patricia A.
2013-01-01
Positive associations have been reported between measures of accelerated fetal growth and risk of childhood acute lymphoblastic leukemia (ALL). We investigated this association by pooling individual-level data from 12 case-control studies participating in the Childhood Leukemia International Consortium. Two measures of fetal growth – weight-for-gestational-age and proportion of optimal birth weight (POBW) – were analysed. Study-specific odds ratios (ORs) and 95% confidence intervals (CIs) were estimated using multivariable logistic regression, and combined in fixed effects meta-analyses. Pooled analyses of all data were also undertaken using multivariable logistic regression. Subgroup analyses were undertaken when possible. Data on weight for gestational age were available for 7,348 cases and 12,489 controls from all 12 studies and POBW data were available for 1,680 cases and 3,139 controls from three studies. The summary ORs from the meta-analyses were 1.24 (95% CI 1.13, 1.36) for children who were large for gestational age relative to appropriate for gestational age, and 1.16 (95% CI: 1.09, 1.24) for a one standard deviation increase in POBW. The pooled analyses produced similar results. The summary and pooled ORs for small-for-gestational-age children were 0.83 (95% CI: 0.75, 0.92) and 0.86 (95% CI 0.77, 0.95) respectively. Results were consistent across subgroups defined by sex, ethnicity and immunophenotype, and when the analysis was restricted to children who did not have high birth weight. The evidence that accelerated fetal growth is associated with a modest increased risk of childhood ALL is strong and consistent with known biological mechanisms involving insulin like growth factors. PMID:23754574
1987 Annual Report of the Reservoir Control Center, Southwestern Division, Army Corps of Engineers
1988-01-01
sediment ranges along the MClellan-Kerr Arkansas River Navigation Project. Due to the funding priorities assigned to reservoir sedimentation resurveys, it’ s...winter with the majority being released in February and March 1988. Numerous small deviations, which ranged from channel work to bridge construction...1987. This was still within the range of the conservation pool. The maximum pool elevation was 6,222.54 (61,668 ac-ft) on 20 June. Pueblo Reservoir is a
Upper arm circumference development in Chinese children and adolescents: a pooled analysis.
Tong, Fang; Fu, Tong
2015-05-30
Upper arm development in children is different in different ethnic groups. There have been few reports on upper arm circumference (UAC) at different stages of development in children and adolescents in China. The purpose of this study was to provide a reference for growth with weighted assessment of the overall level of development. Using a pooled analysis, an authoritative journal database search and reports of UAC, we created a new database on developmental measures in children. In conducting a weighted analysis, we compared reference values for 0~60 months of development according to the World Health Organization (WHO) statistics considering gender and nationality and used Z values as interval values for the second sampling to obtain an exponential smooth curve to analyze the mean, standard deviation, and sites of attachment. Ten articles were included in the pooled analysis, and these articles included participants from different areas of China. The point of intersection with the WHO curve was 3.5 years with higher values at earlier ages and lower values at older ages. Boys curve was steeper after puberty. The curves in the studies had a merged line compatible. The Z values of exponential smoothing showed the curves were similar for body weight and had a right normal distribution. The integrated index of UAC in Chinese children and adolescents indicated slightly variations with regions. Exponential curve smoothing was suitable for assessment at different developmental stages.
Detecting differentially expressed genes in heterogeneous diseases using half Student's t-test.
Hsu, Chun-Lun; Lee, Wen-Chung
2010-12-01
Microarray technology provides information about hundreds and thousands of gene-expression data in a single experiment. To search for disease-related genes, researchers test for those genes that are differentially expressed between the case subjects and the control subjects. The authors propose a new test, the 'half Student's t-test', specifically for detecting differentially expressed genes in heterogeneous diseases. Monte-Carlo simulation shows that the test maintains the nominal α level quite well for both normal and non-normal distributions. Power of the half Student's t is higher than that of the conventional 'pooled' Student's t when there is heterogeneity in the disease under study. The power gain by using the half Student's t can reach ∼10% when the standard deviation of the case group is 50% larger than that of the control group. Application to a colon cancer data reveals that when the false discovery rate (FDR) is controlled at 0.05, the half Student's t can detect 344 differentially expressed genes, whereas the pooled Student's t can detect only 65 genes. Or alternatively, if only 50 genes are to be selected, the FDR for the pooled Student's t has to be set at 0.0320 (false positive rate of ∼3%), but for the half Student's t, it can be at as low as 0.0001 (false positive rate of about one per ten thousands). The half Student's t-test is to be recommended for the detection of differentially expressed genes in heterogeneous diseases.
16 CFR 1207.1 - Scope, purpose, and findings.
Code of Federal Regulations, 2010 CFR
2010-01-01
... SAFETY STANDARD FOR SWIMMING POOL SLIDES § 1207.1 Scope, purpose, and findings. (a) Scope and purpose... Commission for the manufacture and construction of slides for use in swimming pools. The requirements of this... swimming pool slides. This standard also makes certain recommendations regarding the installation...
Exploring Students' Conceptions of the Standard Deviation
ERIC Educational Resources Information Center
delMas, Robert; Liu, Yan
2005-01-01
This study investigated introductory statistics students' conceptual understanding of the standard deviation. A computer environment was designed to promote students' ability to coordinate characteristics of variation of values about the mean with the size of the standard deviation as a measure of that variation. Twelve students participated in an…
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2012 CFR
2012-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2014 CFR
2014-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2011 CFR
2011-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2013 CFR
2013-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
Statistics as Unbiased Estimators: Exploring the Teaching of Standard Deviation
ERIC Educational Resources Information Center
Wasserman, Nicholas H.; Casey, Stephanie; Champion, Joe; Huey, Maryann
2017-01-01
This manuscript presents findings from a study about the knowledge for and planned teaching of standard deviation. We investigate how understanding variance as an unbiased (inferential) estimator--not just a descriptive statistic for the variation (spread) in data--is related to teachers' instruction regarding standard deviation, particularly…
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2010 CFR
2010-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.6 - Tolerances for moisture meters.
Code of Federal Regulations, 2010 CFR
2010-01-01
... moisture, mean deviation from National standard moisture meter using Hard Red Winter wheat Mid ±0.05 percent moisture, mean deviation from National standard moisture meter using Hard Red Winter wheat High ±0.05 percent moisture, mean deviation from National standard moisture meter using Hard Red Winter wheat...
A meta-analysis of the validity of FFQ targeted to adolescents.
Tabacchi, Garden; Filippi, Anna Rita; Amodio, Emanuele; Jemni, Monèm; Bianco, Antonino; Firenze, Alberto; Mammina, Caterina
2016-05-01
The present work is aimed at meta-analysing validity studies of FFQ for adolescents, to investigate their overall accuracy and variables that can affect it negatively. A meta-analysis of sixteen original articles was performed within the ASSO Project (Adolescents and Surveillance System in the Obesity prevention). The articles assessed the validity of FFQ for adolescents, compared with food records or 24 h recalls, with regard to energy and nutrient intakes. Pearson's or Spearman's correlation coefficients, means/standard deviations, kappa agreement, percentiles and mean differences/limits of agreement (Bland-Altman method) were extracted. Pooled estimates were calculated and heterogeneity tested for correlation coefficients and means/standard deviations. A subgroup analysis assessed variables influencing FFQ accuracy. An overall fair/high correlation between FFQ and reference method was found; a good agreement, measured through the intake mean comparison for all nutrients except sugar, carotene and K, was observed. Kappa values showed fair/moderate agreement; an overall good ability to rank adolescents according to energy and nutrient intakes was evidenced by data of percentiles; absolute validity was not confirmed by mean differences/limits of agreement. Interviewer administration mode, consumption interval of the previous year/6 months and high number of food items are major contributors to heterogeneity and thus can reduce FFQ accuracy. The meta-analysis shows that FFQ are accurate tools for collecting data and could be used for ranking adolescents in terms of energy and nutrient intakes. It suggests how the design and the validation of a new FFQ should be addressed.
Development and evaluation of a reservoir model for the Chain of Lakes in Illinois
Domanski, Marian M.
2017-01-27
Forecasts of flows entering and leaving the Chain of Lakes reservoir on the Fox River in northeastern Illinois are critical information to water-resource managers who determine the optimal operation of the dam at McHenry, Illinois, to help minimize damages to property and loss of life because of flooding on the Fox River. In 2014, the U.S. Geological Survey; the Illinois Department of Natural Resources, Office of Water Resources; and National Weather Service, North Central River Forecast Center began a cooperative study to develop a system to enable engineers and planners to simulate and communicate flows and to prepare proactively for precipitation events in near real time in the upper Fox River watershed. The purpose of this report is to document the development and evaluation of the Chain of Lakes reservoir model developed in this study.The reservoir model for the Chain of Lakes was developed using the Hydrologic Engineering Center–Reservoir System Simulation program. Because of the complex relation between the dam headwater and reservoir pool elevations, the reservoir model uses a linear regression model that relates dam headwater elevation to reservoir pool elevation. The linear regression model was developed using 17 U.S. Geological Survey streamflow measurements, along with the gage height in the reservoir pool and the gage height at the dam headwater. The Nash-Sutcliffe model efficiency coefficients for all three linear regression model variables ranged from 0.90 to 0.98.The reservoir model performance was evaluated by graphically comparing simulated and observed reservoir pool elevation time series during nine periods of high pool elevation. In addition, the peak elevations during these time periods were graphically compared to the closest-in-time observed pool elevation peak. The mean difference in the simulated and observed peak elevations was -0.03 feet, with a standard deviation of 0.19 feet. The Nash-Sutcliffe coefficient for peak prediction was calculated as 0.94. Evaluation of the model based on accuracy of peak prediction and the ability to simulate an elevation time series showed the performance of the model was satisfactory.
Visualizing the Sample Standard Deviation
ERIC Educational Resources Information Center
Sarkar, Jyotirmoy; Rashid, Mamunur
2017-01-01
The standard deviation (SD) of a random sample is defined as the square-root of the sample variance, which is the "mean" squared deviation of the sample observations from the sample mean. Here, we interpret the sample SD as the square-root of twice the mean square of all pairwise half deviations between any two sample observations. This…
Evaluation of Brazilian Sugarcane Bagasse Characterization: An Interlaboratory Comparison Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sluiter, Justin B.; Chum, Helena; Gomes, Absai C.
2016-05-01
This paper describes a study of the variability of measured composition for a single bulk sugarcane bagasse conducted across eight laboratories using similar analytical methods, with the purpose of determining the expected variation for compositional analysis performed by different laboratories. The results show good agreement of measured composition within a single laboratory, but greater variability when results are compared among laboratories. These interlaboratory variabilities do not seem to be associated with a specific method or technique or any single piece of instrumentation. The summary censored statistics provide mean values and pooled standard deviations as follows: total extractives 6.7% (0.6%), wholemore » ash 1.5% (0.2%), glucan 42.3% (1.2%), xylan 22.3% (0.5%), total lignin 21.3% (0.4%), and total mass closure 99.4% (2.9%).« less
Han, Xuesong; Zhu, Haihong; Nie, Xiaojia; Wang, Guoqing; Zeng, Xiaoyan
2018-01-01
AlSi10Mg inclined struts with angle of 45° were fabricated by selective laser melting (SLM) using different scanning speed and hatch spacing to gain insight into the evolution of the molten pool morphology, surface roughness, and dimensional accuracy. The results show that the average width and depth of the molten pool, the lower surface roughness and dimensional deviation decrease with the increase of scanning speed and hatch spacing. The upper surface roughness is found to be almost constant under different processing parameters. The width and depth of the molten pool on powder-supported zone are larger than that of the molten pool on the solid-supported zone, while the width changes more significantly than that of depth. However, if the scanning speed is high enough, the width and depth of the molten pool and the lower surface roughness almost keep constant as the density is still high. Therefore, high dimensional accuracy and density as well as good surface quality can be achieved simultaneously by using high scanning speed during SLMed cellular lattice strut. PMID:29518900
Dopkins, Stephen; Varner, Kaitlin; Hoyer, Darin
2017-10-01
In word recognition semantic priming of test words increased the false-alarm rate and the mean of confidence ratings to lures. Such priming also increased the standard deviation of confidence ratings to lures and the slope of the z-ROC function, suggesting that the priming increased the standard deviation of the lure evidence distribution. The Unequal Variance Signal Detection (UVSD) model interpreted the priming as increasing the standard deviation of the lure evidence distribution. Without additional parameters the Dual Process Signal Detection (DPSD) model could only accommodate the results by fitting the data for related and unrelated primes separately, interpreting the priming, implausibly, as decreasing the probability of target recollection (DPSD). With an additional parameter, for the probability of false (lure) recollection the model could fit the data for related and unrelated primes together, interpreting the priming as increasing the probability of false recollection. These results suggest that DPSD estimates of target recollection probability will decrease with increases in the lure confidence/evidence standard deviation unless a parameter is included for false recollection. Unfortunately the size of a given lure confidence/evidence standard deviation relative to other possible lure confidence/evidence standard deviations is often unspecified by context. Hence the model often has no way of estimating false recollection probability and thereby correcting its estimates of target recollection probability.
Down-Looking Interferometer Study II, Volume I,
1980-03-01
g(standard deviation of AN )(standard deviation of(3) where T’rm is the "reference spectrum", an estimate of the actual spectrum v gv T ’V Cgv . If jpj...spectrum T V . cgv . According to Eq. (2), Z is the standard deviation of the observed contrast spectral radiance AN divided by the effective rms system
40 CFR 61.207 - Radium-226 sampling and measurement procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... B, Method 114. (3) Calculate the mean, x 1, and the standard deviation, s 1, of the n 1 radium-226... owner or operator of a phosphogypsum stack shall report the mean, standard deviation, 95th percentile..., Method 114. (4) Recalculate the mean and standard deviation of the entire set of n 2 radium-226...
Zhao, Fei; Tian, Jinhui; An, Lifeng; Yang, Kehu
2014-06-01
The aim of this study was to assess the effectiveness of adding viral vector-mediated gene therapy with herpes simplex virus thymidine kinase (HSV-tk) to standard treatment, in comparison with standard treatment alone to treat patients with high-grade gliomas (HGGs). A literature search of the databases PubMed, Embase, the Cochrane Library, Web of Science, and Chinese biomedicine was performed to identify eligible studies. Three randomized controlled trials (involving a total of 532 patients) were included in this systematic review. A meta-analysis of included studies demonstrated a significant increase in median survival time (MST) in patients who were treated with HSV-tk gene therapy (mean deviation 0.59, 95% CI: 0.41-0.76, p < 0.0001). The results of pooled analysis for different patient groups show that overall survival (OS) for all HGG patients was improved by adding gene therapy [hazard ratio (HR) = 0.91, 95% CI: 0.74-1.13, p = 0.42], while a different result was seen for glioblastoma multiforme (GBM) patients (HR = 1.06, 95% CI: 0.80-1.41, p = 0.70). Furthermore, the combined results for tumor progression implied that standard therapy was superior to gene therapy [odds ratio (OR) = 1.31, p = 0.09]; yet differences in HR and OR between experimental groups and control groups had no statistical significance (p > 0.05). Based on the best available evidence, it appears that adding gene therapy with HSV-tk has some effect in treating HGG patients, especially with respect to MST. However, neither the pooled analysis of OS, nor the combined analysis of tumor progress indicates any significant advantage to adding gene therapy compared with standard treatment alone. More prospective studies are needed to draw solid conclusions about whether gene therapy has significant prognostic advantage.
Briehl, Margaret M; Nelson, Mark A; Krupinski, Elizabeth A; Erps, Kristine A; Holcomb, Michael J; Weinstein, John B; Weinstein, Ronald S
2016-01-01
Faculty members from the Department of Pathology at The University of Arizona College of Medicine-Tucson have offered a 4-credit course on enhanced general pathology for graduate students since 1996. The course is titled, "Mechanisms of Human Disease." Between 1997 and 2016, 270 graduate students completed Mechanisms of Human Disease. The students came from 21 programs of study. Analysis of Variance, using course grade as the dependent and degree, program, gender, and year (1997-2016) as independent variables, indicated that there was no significant difference in final grade (F = 0.112; P = .8856) as a function of degree (doctorate: mean = 89.60, standard deviation = 5.75; master's: mean = 89.34, standard deviation = 6.00; certificate program: mean = 88.64, standard deviation = 8.25), specific type of degree program (F = 2.066, P = .1316; life sciences: mean = 89.95, standard deviation = 6.40; pharmaceutical sciences: mean = 90.71, standard deviation = 4.57; physical sciences: mean = 87.79, standard deviation = 5.17), or as a function of gender (F = 2.96, P = .0865; males: mean = 88.09, standard deviation = 8.36; females: mean = 89.58, standard deviation = 5.82). Students in the physical and life sciences performed equally well. Mechanisms of Human Disease is a popular course that provides students enrolled in a variety of graduate programs with a medical school-based course on mechanisms of diseases. The addition of 2 new medically oriented Master of Science degree programs has nearly tripled enrollment. This graduate level course also potentially expands the interdisciplinary diversity of participants in our interprofessional education and collaborative practice exercises.
Briehl, Margaret M.; Nelson, Mark A.; Krupinski, Elizabeth A.; Erps, Kristine A.; Holcomb, Michael J.; Weinstein, John B.
2016-01-01
Faculty members from the Department of Pathology at The University of Arizona College of Medicine-Tucson have offered a 4-credit course on enhanced general pathology for graduate students since 1996. The course is titled, “Mechanisms of Human Disease.” Between 1997 and 2016, 270 graduate students completed Mechanisms of Human Disease. The students came from 21 programs of study. Analysis of Variance, using course grade as the dependent and degree, program, gender, and year (1997-2016) as independent variables, indicated that there was no significant difference in final grade (F = 0.112; P = .8856) as a function of degree (doctorate: mean = 89.60, standard deviation = 5.75; master’s: mean = 89.34, standard deviation = 6.00; certificate program: mean = 88.64, standard deviation = 8.25), specific type of degree program (F = 2.066, P = .1316; life sciences: mean = 89.95, standard deviation = 6.40; pharmaceutical sciences: mean = 90.71, standard deviation = 4.57; physical sciences: mean = 87.79, standard deviation = 5.17), or as a function of gender (F = 2.96, P = .0865; males: mean = 88.09, standard deviation = 8.36; females: mean = 89.58, standard deviation = 5.82). Students in the physical and life sciences performed equally well. Mechanisms of Human Disease is a popular course that provides students enrolled in a variety of graduate programs with a medical school-based course on mechanisms of diseases. The addition of 2 new medically oriented Master of Science degree programs has nearly tripled enrollment. This graduate level course also potentially expands the interdisciplinary diversity of participants in our interprofessional education and collaborative practice exercises. PMID:28725783
Behavior and structure of metal vapor arc plasma between molten electrodes
NASA Astrophysics Data System (ADS)
Zanner, F. J.; Williamson, R. L.; Hareland, W. A.; Bertram, L. A.
A metal vapor arc is utilized in the industrially important vacuum arc remelting (VAR) process to produce materials by melting and resolidification which have improved structure and chemical homogeneity. Homogeneity is dependent on achieving quasi-steady conditions in the plasma because of its thermal and MHD coupling with the molten pool atop the ingot. Optimal operating conditions of low pressure (approx. = 0.01 torr) and short electrode gap (less than 15 mm) produce a diffuse arc and cathode spot behavior similar to that observed for the vacuum breaker arc. Under these conditions the arc provides a quasi-steady heat source that is considered to be the bench mark arc of the VAR process. Previous work has shown that deviation from the bench mark arc behavior can occur under production conditions, and is caused by electrode irregularities and liberation of gases such as CO from the molten pool. This study is an effort to characterize these behavioral deviations and discover operational conditions which stabilize the bench mark arc.
Tucker, Jalie A; Roth, David L; Vignolo, Mary J; Westfall, Andrew O
2009-04-01
Data were pooled from 3 studies of recently resolved community-dwelling problem drinkers to determine whether a behavioral economic index of the value of rewards available over different time horizons distinguished among moderation (n = 30), abstinent (n = 95), and unresolved (n = 77) outcomes. Moderation over 1- to 2-year prospective follow-up intervals was hypothesized to involve longer term behavior regulation processes than abstinence or relapse and to be predicted by more balanced preresolution monetary allocations between short-term and longer term objectives (i.e., drinking and saving for the future). Standardized odds ratios (ORs) based on changes in standard deviation units from a multinomial logistic regression indicated that increases on this "Alcohol-Savings Discretionary Expenditure" index predicted higher rates of abstinence (OR = 1.93, p = .004) and relapse (OR = 2.89, p < .0001) compared with moderation outcomes. The index had incremental utility in predicting moderation in complex models that included other established predictors. The study adds to evidence supporting a behavioral economic analysis of drinking resolutions and shows that a systematic analysis of preresolution spending patterns aids in predicting moderation.
Townsend, E; Hawton, K; Altman, D G; Arensman, E; Gunnell, D; Hazell, P; House, A; Van Heeringen, K
2001-08-01
Brief problem-solving therapy is regarded as a pragmatic treatment for deliberate self-harm (DSH) patients. A recent meta-analysis of randomized controlled trials (RCTs) evaluating this approach indicated a trend towards reduced repetition of DSH but the pooled odds ratio was not statistically significant. We have now examined other important outcomes using this procedure, namely depression, hopelessness and improvement in problems. Six trials in which problem-solving therapy was compared with control treatment were identified from an extensive literature review of RCTs of treatments for DSH patients. Data concerning depression, hopelessness and improvement in problems were extracted. Where relevant statistical data (e.g. standard deviations) were missing these were imputed using various statistical methods. Results were pooled using meta-analytical procedures. At follow-up, patients who were offered problem-solving therapy had significantly greater improvement in scores for depression (standardized mean difference = -0.36; 95% CI -0.61 to -0.11) and hopelessness (weighted mean difference =-3.2; 95% CI -4.0 to -2.41), and significantly more reported improvement in their problems (odds ratio = 2.31; 95% CI 1.29 to 4.13), than patients who were in the control treatment groups. Problem-solving therapy for DSH patients appears to produce better results than control treatment with regard to improvement in depression, hopelessness and problems. It is desirable that this finding is confirmed in a large trial, which will also allow adequate testing of the impact of this treatment on repetition of DSH.
A Note on Standard Deviation and Standard Error
ERIC Educational Resources Information Center
Hassani, Hossein; Ghodsi, Mansoureh; Howell, Gareth
2010-01-01
Many students confuse the standard deviation and standard error of the mean and are unsure which, if either, to use in presenting data. In this article, we endeavour to address these questions and cover some related ambiguities about these quantities.
Bolann, B J; Asberg, A
2004-01-01
The deviation of test results from patients' homeostatic set points in steady-state conditions may complicate interpretation of the results and the comparison of results with clinical decision limits. In this study the total deviation from the homeostatic set point is defined as the maximum absolute deviation for 95% of measurements, and we present analytical quality requirements that prevent analytical error from increasing this deviation to more than about 12% above the value caused by biology alone. These quality requirements are: 1) The stable systematic error should be approximately 0, and 2) a systematic error that will be detected by the control program with 90% probability, should not be larger than half the value of the combined analytical and intra-individual standard deviation. As a result, when the most common control rules are used, the analytical standard deviation may be up to 0.15 times the intra-individual standard deviation. Analytical improvements beyond these requirements have little impact on the interpretability of measurement results.
NASA Astrophysics Data System (ADS)
Guillard-Gonçalves, C.; Zêzere, J. L.; Pereira, S.; Garcia, R. A. C.
2016-02-01
This study offers a semi-quantitative assessment of the physical vulnerability of buildings to landslides in a Portuguese municipality (Loures), as well as the quantitative landslide risk analysis computed as the product of the landslide hazard by the vulnerability and the economic value of the buildings. The hazard was assessed by combining the spatiotemporal probability and the frequency-magnitude relationship of the landslides. The physical vulnerability assessment was based on an inquiry of a pool of European landslide experts and a sub-pool of landslide experts who know the study area, and the answers' variability was assessed with standard deviation. The average vulnerability of the basic geographic entities was compared by changing the map unit and applying the vulnerability to all the buildings of a test site, the inventory of which was listed on the field. The economic value was calculated using an adaptation of the Portuguese Tax Services approach, and the risk was computed for different landslide magnitudes and different spatiotemporal probabilities. As a rule, the vulnerability values given by the sub-pool of experts who know the study area are higher than those given by the European experts, namely for the high-magnitude landslides. The obtained vulnerabilities vary from 0.2 to 1 as a function of the structural building types and the landslide magnitude, and are maximal for 10 and 20 m landslide depths. However, the highest risk was found for the landslides that are 3 m deep, because these landslides combine a relatively high frequency in the Loures municipality with a substantial potential damage.
Code of Federal Regulations, 2010 CFR
2010-01-01
... defined in section 1 of this appendix is as follows: (a) The standard deviation of lateral track errors shall be less than 6.3 NM (11.7 Km). Standard deviation is a statistical measure of data about a mean... standard deviation about the mean encompasses approximately 68 percent of the data and plus or minus 2...
Spread of large LNG pools on the sea.
Fay, J A
2007-02-20
A review of the standard model of LNG pool spreading on water, comparing it with the model and experiments on oil pool spread from which the LNG model is extrapolated, raises questions about the validity of the former as applied to spills from marine tankers. These questions arise from the difference in fluid density ratios, in the multi-dimensional flow at the pool edge, in the effects of LNG pool boiling at the LNG-water interface, and in the model and experimental initial conditions compared with the inflow conditions from a marine tanker spill. An alternate supercritical flow model is proposed that avoids these difficulties; it predicts significant increase in the maximum pool radius compared with the standard model and is partially corroborated by tests of LNG pool fires on water. Wind driven ocean wave interaction has little effect on either spread model.
Lin, P.-S.; Chiou, B.; Abrahamson, N.; Walling, M.; Lee, C.-T.; Cheng, C.-T.
2011-01-01
In this study, we quantify the reduction in the standard deviation for empirical ground-motion prediction models by removing ergodic assumption.We partition the modeling error (residual) into five components, three of which represent the repeatable source-location-specific, site-specific, and path-specific deviations from the population mean. A variance estimation procedure of these error components is developed for use with a set of recordings from earthquakes not heavily clustered in space.With most source locations and propagation paths sampled only once, we opt to exploit the spatial correlation of residuals to estimate the variances associated with the path-specific and the source-location-specific deviations. The estimation procedure is applied to ground-motion amplitudes from 64 shallow earthquakes in Taiwan recorded at 285 sites with at least 10 recordings per site. The estimated variance components are used to quantify the reduction in aleatory variability that can be used in hazard analysis for a single site and for a single path. For peak ground acceleration and spectral accelerations at periods of 0.1, 0.3, 0.5, 1.0, and 3.0 s, we find that the singlesite standard deviations are 9%-14% smaller than the total standard deviation, whereas the single-path standard deviations are 39%-47% smaller.
Luo, Dehui; Wan, Xiang; Liu, Jiming; Tong, Tiejun
2018-06-01
The era of big data is coming, and evidence-based medicine is attracting increasing attention to improve decision making in medical practice via integrating evidence from well designed and conducted clinical research. Meta-analysis is a statistical technique widely used in evidence-based medicine for analytically combining the findings from independent clinical trials to provide an overall estimation of a treatment effectiveness. The sample mean and standard deviation are two commonly used statistics in meta-analysis but some trials use the median, the minimum and maximum values, or sometimes the first and third quartiles to report the results. Thus, to pool results in a consistent format, researchers need to transform those information back to the sample mean and standard deviation. In this article, we investigate the optimal estimation of the sample mean for meta-analysis from both theoretical and empirical perspectives. A major drawback in the literature is that the sample size, needless to say its importance, is either ignored or used in a stepwise but somewhat arbitrary manner, e.g. the famous method proposed by Hozo et al. We solve this issue by incorporating the sample size in a smoothly changing weight in the estimators to reach the optimal estimation. Our proposed estimators not only improve the existing ones significantly but also share the same virtue of the simplicity. The real data application indicates that our proposed estimators are capable to serve as "rules of thumb" and will be widely applied in evidence-based medicine.
Lazzaroni, Sara; Wagner, Natascha
2016-12-01
This study considers the two most pronounced shocks Senegalese subsistence farmers struggle with, namely increasing purchase prices and droughts. We assess the relationship of these self-reported shocks with child health in a multi-shock approach to account for concomitance of adverse events from the natural, biological, economic and health sphere. We employ a unique farming household panel dataset containing information on children living in poor, rural households in eight regions of Senegal in 2009 and 2011 and account for structural changes occurring between survey periods due to the large scale, national Nutrition Enhancement Program. By zooming in to the micro level we demonstrate that Senegal as a Sahelian country, mainly reliant on subsistence agriculture, is very vulnerable to climate variability and international price developments: According to our conservative estimates, the occurrence of a drought explains 25% of the pooled weight-for-age standard deviation, income losses 31%. Our multi-shock analysis reveals that the shocks are perceived as more severe in 2011 with droughts explaining up to 44% of the standard deviation of child health, increased prices up to 21%. Yet, the concomitance of droughts and increased prices after the structural change, i.e. the Nutrition Enhancement Program, indicates that the health of children experiencing both shocks in 2011 has improved. We argue that these results are driven by the increase in rural household income as theoretically outlined in the agricultural household model. Thus, adequate policy responses to shocks do not only depend on the nature but also on the concomitance of hazardous events. Copyright © 2016 Elsevier B.V. All rights reserved.
A better norm-referenced grading using the standard deviation criterion.
Chan, Wing-shing
2014-01-01
The commonly used norm-referenced grading assigns grades to rank-ordered students in fixed percentiles. It has the disadvantage of ignoring the actual distance of scores among students. A simple norm-referenced grading via standard deviation is suggested for routine educational grading. The number of standard deviation of a student's score from the class mean was used as the common yardstick to measure achievement level. Cumulative probability of a normal distribution was referenced to help decide the amount of students included within a grade. RESULTS of the foremost 12 students from a medical examination were used for illustrating this grading method. Grading by standard deviation seemed to produce better cutoffs in allocating an appropriate grade to students more according to their differential achievements and had less chance in creating arbitrary cutoffs in between two similarly scored students than grading by fixed percentile. Grading by standard deviation has more advantages and is more flexible than grading by fixed percentile for norm-referenced grading.
Johnson, Craig W; Johnson, Ronald; Kim, Mira; McKee, John C
2009-11-01
During 2004 and 2005 orientations, all 187 and 188 new matriculates, respectively, in two southwestern U.S. nursing schools completed Personal Background and Preparation Surveys (PBPS) in the first predictive validity study of a diagnostic and prescriptive instrument for averting adverse academic status events (AASE) among nursing or health science professional students. One standard deviation increases in PBPS risks (p < 0.05) multiplied odds of first-year or second-year AASE by approximately 150%, controlling for school affiliation and underrepresented minority student (URMS) status. AASE odds one standard deviation above mean were 216% to 250% those one standard deviation below mean. Odds of first-year or second-year AASE for URMS one standard deviation above the 2004 PBPS mean were 587% those for non-URMS one standard deviation below mean. The PBPS consistently and significantly facilitated early identification of nursing students at risk for AASE, enabling proactive targeting of interventions for risk amelioration and AASE or attrition prevention. Copyright 2009, SLACK Incorporated.
Demonstration of the Gore Module for Passive Ground Water Sampling
2014-06-01
ix ACRONYMS AND ABBREVIATIONS % RSD percent relative standard deviation 12DCA 1,2-dichloroethane 112TCA 1,1,2-trichloroethane 1122TetCA...Analysis of Variance ROD Record of Decision RSD relative standard deviation SBR Southern Bush River SVOC semi-volatile organic compound...replicate samples had a relative standard deviation ( RSD ) that was 20% or less. For the remaining analytes (PCE, cDCE, and chloroform), at least 70
Wang, Anxin; Li, Zhifang; Yang, Yuling; Chen, Guojuan; Wang, Chunxue; Wu, Yuntao; Ruan, Chunyu; Liu, Yan; Wang, Yilong; Wu, Shouling
2016-01-01
To investigate the relationship between baseline systolic blood pressure (SBP) and visit-to-visit blood pressure variability in a general population. This is a prospective longitudinal cohort study on cardiovascular risk factors and cardiovascular or cerebrovascular events. Study participants attended a face-to-face interview every 2 years. Blood pressure variability was defined using the standard deviation and coefficient of variation of all SBP values at baseline and follow-up visits. The coefficient of variation is the ratio of the standard deviation to the mean SBP. We used multivariate linear regression models to test the relationships between SBP and standard deviation, and between SBP and coefficient of variation. Approximately 43,360 participants (mean age: 48.2±11.5 years) were selected. In multivariate analysis, after adjustment for potential confounders, baseline SBPs <120 mmHg were inversely related to standard deviation (P<0.001) and coefficient of variation (P<0.001). In contrast, baseline SBPs ≥140 mmHg were significantly positively associated with standard deviation (P<0.001) and coefficient of variation (P<0.001). Baseline SBPs of 120-140 mmHg were associated with the lowest standard deviation and coefficient of variation. The associations between baseline SBP and standard deviation, and between SBP and coefficient of variation during follow-ups showed a U curve. Both lower and higher baseline SBPs were associated with increased blood pressure variability. To control blood pressure variability, a good target SBP range for a general population might be 120-139 mmHg.
Weinstein, Ronald S; Krupinski, Elizabeth A; Weinstein, John B; Graham, Anna R; Barker, Gail P; Erps, Kristine A; Holtrust, Angelette L; Holcomb, Michael J
2016-01-01
A medical school general pathology course has been reformatted into a K-12 general pathology course. This new course has been implemented at a series of 7 to 12 grade levels and the student outcomes compared. Typically, topics covered mirrored those in a medical school general pathology course serving as an introduction to the mechanisms of diseases. Assessment of student performance was based on their score on a multiple-choice final examination modeled after an examination given to medical students. Two Tucson area schools, in a charter school network, participated in the study. Statistical analysis of examination performances showed that there were no significant differences as a function of school ( F = 0.258, P = .6128), with students at school A having an average test scores of 87.03 (standard deviation = 8.99) and school B 86.00 (standard deviation = 8.18; F = 0.258, P = .6128). Analysis of variance was also conducted on the test scores as a function of gender and class grade. There were no significant differences as a function of gender ( F = 0.608, P = .4382), with females having an average score of 87.18 (standard deviation = 7.24) and males 85.61 (standard deviation = 9.85). There were also no significant differences as a function of grade level ( F = 0.627, P = .6003), with 7th graders having an average of 85.10 (standard deviation = 8.90), 8th graders 86.00 (standard deviation = 9.95), 9th graders 89.67 (standard deviation = 5.52), and 12th graders 86.90 (standard deviation = 7.52). The results demonstrated that middle and upper school students performed equally well in K-12 general pathology. Student course evaluations showed that the course met the student's expectations. One class voted K-12 general pathology their "elective course-of-the-year."
Flexner 3.0—Democratization of Medical Knowledge for the 21st Century
Krupinski, Elizabeth A.; Weinstein, John B.; Graham, Anna R.; Barker, Gail P.; Erps, Kristine A.; Holtrust, Angelette L.; Holcomb, Michael J.
2016-01-01
A medical school general pathology course has been reformatted into a K-12 general pathology course. This new course has been implemented at a series of 7 to 12 grade levels and the student outcomes compared. Typically, topics covered mirrored those in a medical school general pathology course serving as an introduction to the mechanisms of diseases. Assessment of student performance was based on their score on a multiple-choice final examination modeled after an examination given to medical students. Two Tucson area schools, in a charter school network, participated in the study. Statistical analysis of examination performances showed that there were no significant differences as a function of school (F = 0.258, P = .6128), with students at school A having an average test scores of 87.03 (standard deviation = 8.99) and school B 86.00 (standard deviation = 8.18; F = 0.258, P = .6128). Analysis of variance was also conducted on the test scores as a function of gender and class grade. There were no significant differences as a function of gender (F = 0.608, P = .4382), with females having an average score of 87.18 (standard deviation = 7.24) and males 85.61 (standard deviation = 9.85). There were also no significant differences as a function of grade level (F = 0.627, P = .6003), with 7th graders having an average of 85.10 (standard deviation = 8.90), 8th graders 86.00 (standard deviation = 9.95), 9th graders 89.67 (standard deviation = 5.52), and 12th graders 86.90 (standard deviation = 7.52). The results demonstrated that middle and upper school students performed equally well in K-12 general pathology. Student course evaluations showed that the course met the student’s expectations. One class voted K-12 general pathology their “elective course-of-the-year.” PMID:28725762
17 CFR 4.22 - Reporting to pool participants.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., the financial statements are not required to include consolidated information for all series. (7) For... event that the International Financial Reporting Standards require consolidated financial statements for... reporting pool's consolidated financial statements. (ii) The commodity pool operator of a pool that meets...
Estimation of the neural drive to the muscle from surface electromyograms
NASA Astrophysics Data System (ADS)
Hofmann, David
Muscle force is highly correlated with the standard deviation of the surface electromyogram (sEMG) produced by the active muscle. Correctly estimating this quantity of non-stationary sEMG and understanding its relation to neural drive and muscle force is of paramount importance. The single constituents of the sEMG are called motor unit action potentials whose biphasic amplitude can interfere (named amplitude cancellation), potentially affecting the standard deviation (Keenan etal. 2005). However, when certain conditions are met the Campbell-Hardy theorem suggests that amplitude cancellation does not affect the standard deviation. By simulation of the sEMG, we verify the applicability of this theorem to myoelectric signals and investigate deviations from its conditions to obtain a more realistic setting. We find no difference in estimated standard deviation with and without interference, standing in stark contrast to previous results (Keenan etal. 2008, Farina etal. 2010). Furthermore, since the theorem provides us with the functional relationship between standard deviation and neural drive we conclude that complex methods based on high density electrode arrays and blind source separation might not bear substantial advantages for neural drive estimation (Farina and Holobar 2016). Funded by NIH Grant Number 1 R01 EB022872 and NSF Grant Number 1208126.
Comparison of a novel fixation device with standard suturing methods for spinal cord stimulators.
Bowman, Richard G; Caraway, David; Bentley, Ishmael
2013-01-01
Spinal cord stimulation is a well-established treatment for chronic neuropathic pain of the trunk or limbs. Currently, the standard method of fixation is to affix the leads of the neuromodulation device to soft tissue, fascia or ligament, through the use of manually tying general suture. A novel semiautomated device is proposed that may be advantageous to the current standard. Comparison testing in an excised caprine spine and simulated bench top model was performed. Three tests were performed: 1) perpendicular pull from fascia of caprine spine; 2) axial pull from fascia of caprine spine; and 3) axial pull from Mylar film. Six samples of each configuration were tested for each scenario. Standard 2-0 Ethibond was compared with a novel semiautomated device (Anulex fiXate). Upon completion of testing statistical analysis was performed for each scenario. For perpendicular pull in the caprine spine, the failure load for standard suture was 8.95 lbs with a standard deviation of 1.39 whereas for fiXate the load was 15.93 lbs with a standard deviation of 2.09. For axial pull in the caprine spine, the failure load for standard suture was 6.79 lbs with a standard deviation of 1.55 whereas for fiXate the load was 12.31 lbs with a standard deviation of 4.26. For axial pull in Mylar film, the failure load for standard suture was 10.87 lbs with a standard deviation of 1.56 whereas for fiXate the load was 19.54 lbs with a standard deviation of 2.24. These data suggest a novel semiautomated device offers a method of fixation that may be utilized in lieu of standard suturing methods as a means of securing neuromodulation devices. Data suggest the novel semiautomated device in fact may provide a more secure fixation than standard suturing methods. © 2012 International Neuromodulation Society.
Computer Programs for the Semantic Differential: Further Modifications.
ERIC Educational Resources Information Center
Lawson, Edwin D.; And Others
The original nine programs for semantic differential analysis have been condensed into three programs which have been further refined and augmented. They yield: (1) means, standard deviations, and standard errors for each subscale on each concept; (2) Evaluation, Potency, and Activity (EPA) means, standard deviations, and standard errors; (3)…
Determining a one-tailed upper limit for future sample relative reproducibility standard deviations.
McClure, Foster D; Lee, Jung K
2006-01-01
A formula was developed to determine a one-tailed 100p% upper limit for future sample percent relative reproducibility standard deviations (RSD(R),%= 100s(R)/y), where S(R) is the sample reproducibility standard deviation, which is the square root of a linear combination of the sample repeatability variance (s(r)2) plus the sample laboratory-to-laboratory variance (s(L)2), i.e., S(R) = s(L)2, and y is the sample mean. The future RSD(R),% is expected to arise from a population of potential RSD(R),% values whose true mean is zeta(R),% = 100sigmaR, where sigmaR and mu are the population reproducibility standard deviation and mean, respectively.
Geades, Nicolas; Hunt, Benjamin A E; Shah, Simon M; Peters, Andrew; Mougin, Olivier E; Gowland, Penny A
2017-08-01
To develop a method that fits a multipool model to z-spectra acquired from non-steady state sequences, taking into account the effects of variations in T1 or B1 amplitude and the results estimating the parameters for a four-pool model to describe the z-spectrum from the healthy brain. We compared measured spectra with a look-up table (LUT) of possible spectra and investigated the potential advantages of simultaneously considering spectra acquired at different saturation powers (coupled spectra) to provide sensitivity to a range of different physicochemical phenomena. The LUT method provided reproducible results in healthy controls. The average values of the macromolecular pool sizes measured in white matter (WM) and gray matter (GM) of 10 healthy volunteers were 8.9% ± 0.3% (intersubject standard deviation) and 4.4% ± 0.4%, respectively, whereas the average nuclear Overhauser effect pool sizes in WM and GM were 5% ± 0.1% and 3% ± 0.1%, respectively, and average amide proton transfer pool sizes in WM and GM were 0.21% ± 0.03% and 0.20% ± 0.02%, respectively. The proposed method demonstrated increased robustness when compared with existing methods (such as Lorentzian fitting and asymmetry analysis) while yielding fully quantitative results. The method can be adjusted to measure other parameters relevant to the z-spectrum. Magn Reson Med 78:645-655, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
Patel, K; Abbassi-Ghadi, N; Markar, S; Kumar, S; Jethwa, P; Zaninotto, G
2016-10-01
Peroral endoscopic myotomy (POEM) is a novel approach to performing esophageal myotomy for the treatment of achalasia. This review aims to assess subjective and objective metrics of achalasia treatment efficacy, perioperative adverse events and the incidence of postoperative gastroesophageal reflux disease in patients treated with POEM. Secondary aims include a pooled analysis comparison of the clinical outcomes and procedural safety of POEM versus laparoscopic Heller's myotomy (LHM). A systematic review of the literature, up to and including January 15, 2015, was conducted for studies reporting POEM outcomes. Studies comparing POEM to LHM were also included for the purpose of pooled analysis. Outcomes from 1122 POEM patients, from 22 studies, are reported in this systematic review. Minor operative adverse events included capno/pneumo-peritoneum (30.6%), capno/pneumo-thorax (11.0%) and subcutaneous emphysema (31.6%). Major operative adverse events included mediastinal leak (0.3%), postoperative bleeding (1.1%) and a single mortality (0.09%). There was an improvement in lower esophageal sphincter pressure and timed barium esophagram column height of 66% and 80% post-POEM, respectively. Symptom improvement was demonstrated with a pre- and post-POEM Eckardt score ± standard deviation of 6.8 ± 1.0 and 1.2 ± 0.6, respectively. Pre- and post-POEM endoscopy showed esophagitis in 0% and 19% of patients, respectively. The median (interquartile range) points scored for study quality was 15 (14-16) out of total of 32. Pooled analysis of three comparative studies between LHM and POEM showed similar results for adverse events, perforation rate, operative time and a nonsignificant trend toward a reduced length of hospital stay in the POEM group. In conclusion, POEM is a safe and effective treatment for achalasia, showing significant improvements in objective metrics and achalasia-related symptoms. Randomized comparative studies of LHM and POEM are required to determine the most effective treatment modality for achalasia. © 2015 International Society for Diseases of the Esophagus.
Effect of obstructive sleep apnea hypopnea syndrome on lipid profile: a meta-regression analysis.
Nadeem, Rashid; Singh, Mukesh; Nida, Mahwish; Waheed, Irfan; Khan, Adnan; Ahmed, Saeed; Naseem, Jawed; Champeau, Daniel
2014-05-15
Obstructive sleep apnea (OSA) is associated with obesity, metabolic syndrome, and dyslipidemia, which may be related to decrease androgen levels found in OSA patients. Dyslipidemia may contribute to atherosclerosis leading to increasing risk of heart disease. Systematic review was conducted using PubMed and Cochrane library by utilizing different combinations of key words; sleep apnea, obstructive sleep apnea, serum lipids, dyslipidemia, cholesterol, total cholesterol, low density lipoprotein (LDL), high density lipoprotein (HDL), and triglyceride (TG). Inclusion criteria were: English articles, and studies with adult population in 2 groups of patients (patients with OSA and without OSA). A total 96 studies were reviewed for inclusion, with 25 studies pooled for analysis. Sixty-four studies were pooled for analysis; since some studies have more than one dataset, there were 107 datasets with 18,116 patients pooled for meta-analysis. All studies measured serum lipids. Total cholesterol pooled standardized difference in means was 0.267 (p = 0.001). LDL cholesterol pooled standardized difference in means was 0.296 (p = 0.001). HDL cholesterol pooled standardized difference in means was -0.433 (p = 0.001). Triglyceride pooled standardized difference in means was 0.603 (p = 0.001). Meta-regression for age, BMI, and AHI showed that age has significant effect for TC, LDL, and HDL. BMI had significant effect for LDL and HDL, while AHI had significant effect for LDL and TG. Patients with OSA appear to have increased dyslipidemia (high total cholesterol, LDL, TG, and low HDL).
POOL server: machine learning application for functional site prediction in proteins.
Somarowthu, Srinivas; Ondrechen, Mary Jo
2012-08-01
We present an automated web server for partial order optimum likelihood (POOL), a machine learning application that combines computed electrostatic and geometric information for high-performance prediction of catalytic residues from 3D structures. Input features consist of THEMATICS electrostatics data and pocket information from ConCavity. THEMATICS measures deviation from typical, sigmoidal titration behavior to identify functionally important residues and ConCavity identifies binding pockets by analyzing the surface geometry of protein structures. Both THEMATICS and ConCavity (structure only) do not require the query protein to have any sequence or structure similarity to other proteins. Hence, POOL is applicable to proteins with novel folds and engineered proteins. As an additional option for cases where sequence homologues are available, users can include evolutionary information from INTREPID for enhanced accuracy in site prediction. The web site is free and open to all users with no login requirements at http://www.pool.neu.edu. m.ondrechen@neu.edu Supplementary data are available at Bioinformatics online.
Packing Fraction of a Two-dimensional Eden Model with Random-Sized Particles
NASA Astrophysics Data System (ADS)
Kobayashi, Naoki; Yamazaki, Hiroshi
2018-01-01
We have performed a numerical simulation of a two-dimensional Eden model with random-size particles. In the present model, the particle radii are generated from a Gaussian distribution with mean μ and standard deviation σ. First, we have examined the bulk packing fraction for the Eden cluster and investigated the effects of the standard deviation and the total number of particles NT. We show that the bulk packing fraction depends on the number of particles and the standard deviation. In particular, for the dependence on the standard deviation, we have determined the asymptotic value of the bulk packing fraction in the limit of the dimensionless standard deviation. This value is larger than the packing fraction obtained in a previous study of the Eden model with uniform-size particles. Secondly, we have investigated the packing fraction of the entire Eden cluster including the effect of the interface fluctuation. We find that the entire packing fraction depends on the number of particles while it is independent of the standard deviation, in contrast to the bulk packing fraction. In a similar way to the bulk packing fraction, we have obtained the asymptotic value of the entire packing fraction in the limit NT → ∞. The obtained value of the entire packing fraction is smaller than that of the bulk value. This fact suggests that the interface fluctuation of the Eden cluster influences the packing fraction.
Complexities of follicle deviation during selection of a dominant follicle in Bos taurus heifers.
Ginther, O J; Baldrighi, J M; Siddiqui, M A R; Araujo, E R
2016-11-01
Follicle deviation during a follicular wave is a continuation in growth rate of the dominant follicle (F1) and decreased growth rate of the largest subordinate follicle (F2). The reliability of using an F1 of 8.5 mm to represent the beginning of expected deviation for experimental purposes during waves 1 and 2 (n = 26 per wave) was studied daily in heifers. Each wave was subgrouped as follows: standard subgroup (F1 larger than F2 for 2 days preceding deviation and F2 > 7.0 mm on the day of deviation), undersized subgroup (F2 did not attain 7.0 mm by the day of deviation), and switched subgroup (F2 larger than F1 at least once on the 2 days before or on the day of deviation). For each wave, mean differences in diameter between F1 and F2 changed abruptly at expected deviation in the standard subgroup but began 1 day before expected deviation in the undersized and switched subgroups. Concentrations of FSH in the wave-stimulating FSH surge and an increase in LH centered on expected deviation did not differ among subgroups. Results for each wave indicated that (1) expected deviation (F1, 8.5 mm) was a reliable representation of actual deviation in the standard subgroup but not in the undersized and switched subgroups; (2) concentrations of the gonadotropins normalized to expected deviation were similar among the three subgroups, indicating that the day of deviation was related to diameter of F1 and not F2; and (3) defining an expected day of deviation for experimental use should consider both diameter of F1 and the characteristics of deviation. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Guillard-Gonçalves, Clémence; Zêzere, José Luis; Pereira, Susana; Garcia, Ricardo
2016-04-01
The physical vulnerability of the buildings of Loures (a Portuguese municipality) to landslides was assessed, and the landslide risk was computed as the product of the landslide hazard by the vulnerability and the market economic value of the buildings. First, the hazard was assessed by combining the spatio-temporal probability and the frequency-magnitude relationship of the landslides, which was established by plotting the probability of a landslide area. The susceptibility of deep-seated and shallow landslides was assessed by a bi-variate statistical method and was mapped. The annual and multiannual spatio-temporal probabilities were estimated, providing a landslide hazard model. Then, an assessment of buildings vulnerability to landslides, based on an inquiry of a pool of landslide European experts, was developed and applied to the study area. The inquiry was based on nine magnitude scenarios and four structural building types. A sub-pool of the landslide experts who know the study area was extracted from the pool, and the variability of the answers coming from the pool and the sub-pool was assessed with standard deviation. Moreover, the average vulnerability of the basic geographic entities was compared by changing the map unit and applying the vulnerability to all the buildings of a test site (included in the study area), the inventory of which was listed on the field. Next, the market economic value of the buildings was calculated using an adaptation of the Portuguese Tax Services approach. Finally, the annual and multiannual landslide risk was computed for the nine landslide magnitude scenarios and different spatio-temporal probabilities by multiplying the potential loss (Vulnerability × Economic Value) by the hazard probability. As a rule, the vulnerability values given by the sub-pool of experts who know the study area are higher than those given by the European experts, namely for the high magnitude landslides. The obtained vulnerabilities vary from 0.2 to 1 as a function of the structural building types and the landslide magnitude, and are maximal for 10 and 20 meters landslide depths. However, the highest annual risk was found for the 3 m deep landslides, with a maximum value of 25.68 € per 5 m pixel, which is explained by the combination of a relatively high frequency in the Loures municipality with a substantial potential damage.
40 CFR 90.708 - Cumulative Sum (CumSum) procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... is 5.0×σ, and is a function of the standard deviation, σ. σ=is the sample standard deviation and is... individual engine. FEL=Family Emission Limit (the standard if no FEL). F=.25×σ. (2) After each test pursuant...
2015-01-01
The goal of this study was to analyse perceptually and acoustically the voices of patients with Unilateral Vocal Fold Paralysis (UVFP) and compare them to the voices of normal subjects. These voices were analysed perceptually with the GRBAS scale and acoustically using the following parameters: mean fundamental frequency (F0), standard-deviation of F0, jitter (ppq5), shimmer (apq11), mean harmonics-to-noise ratio (HNR), mean first (F1) and second (F2) formants frequency, and standard-deviation of F1 and F2 frequencies. Statistically significant differences were found in all of the perceptual parameters. Also the jitter, shimmer, HNR, standard-deviation of F0, and standard-deviation of the frequency of F2 were statistically different between groups, for both genders. In the male data differences were also found in F1 and F2 frequencies values and in the standard-deviation of the frequency of F1. This study allowed the documentation of the alterations resulting from UVFP and addressed the exploration of parameters with limited information for this pathology. PMID:26557690
NASA Astrophysics Data System (ADS)
Krasnenko, N. P.; Kapegesheva, O. F.; Shamanaeva, L. G.
2017-11-01
Spatiotemporal dynamics of the standard deviations of three wind velocity components measured with a mini-sodar in the atmospheric boundary layer is analyzed. During the day on September 16 and at night on September 12 values of the standard deviation changed for the x- and y-components from 0.5 to 4 m/s, and for the z-component from 0.2 to 1.2 m/s. An analysis of the vertical profiles of the standard deviations of three wind velocity components for a 6-day measurement period has shown that the increase of σx and σy with altitude is well described by a power law dependence with exponent changing from 0.22 to 1.3 depending on the time of day, and σz depends linearly on the altitude. The approximation constants have been found and their errors have been estimated. The established physical regularities and the approximation constants allow the spatiotemporal dynamics of the standard deviation of three wind velocity components in the atmospheric boundary layer to be described and can be recommended for application in ABL models.
A proof for Rhiel's range estimator of the coefficient of variation for skewed distributions.
Rhiel, G Steven
2007-02-01
In this research study is proof that the coefficient of variation (CV(high-low)) calculated from the highest and lowest values in a set of data is applicable to specific skewed distributions with varying means and standard deviations. Earlier Rhiel provided values for d(n), the standardized mean range, and a(n), an adjustment for bias in the range estimator of micro. These values are used in estimating the coefficient of variation from the range for skewed distributions. The d(n) and an values were specified for specific skewed distributions with a fixed mean and standard deviation. In this proof it is shown that the d(n) and an values are applicable for the specific skewed distributions when the mean and standard deviation can take on differing values. This will give the researcher confidence in using this statistic for skewed distributions regardless of the mean and standard deviation.
Random errors in interferometry with the least-squares method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Qi
2011-01-20
This investigation analyzes random errors in interferometric surface profilers using the least-squares method when random noises are present. Two types of random noise are considered here: intensity noise and position noise. Two formulas have been derived for estimating the standard deviations of the surface height measurements: one is for estimating the standard deviation when only intensity noise is present, and the other is for estimating the standard deviation when only position noise is present. Measurements on simulated noisy interferometric data have been performed, and standard deviations of the simulated measurements have been compared with those theoretically derived. The relationships havemore » also been discussed between random error and the wavelength of the light source and between random error and the amplitude of the interference fringe.« less
N2/O2/H2 Dual-Pump Cars: Validation Experiments
NASA Technical Reports Server (NTRS)
OByrne, S.; Danehy, P. M.; Cutler, A. D.
2003-01-01
The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method is used to measure temperature and the relative species densities of N2, O2 and H2 in two experiments. Average values and root-mean-square (RMS) deviations are determined. Mean temperature measurements in a furnace containing air between 300 and 1800 K agreed with thermocouple measurements within 26 K on average, while mean mole fractions agree to within 1.6 % of the expected value. The temperature measurement standard deviation averaged 64 K while the standard deviation of the species mole fractions averaged 7.8% for O2 and 3.8% for N2, based on 200 single-shot measurements. Preliminary measurements have also been performed in a flat-flame burner for fuel-lean and fuel-rich flames. Temperature standard deviations of 77 K were measured, and the ratios of H2 to N2 and O2 to N2 respectively had standard deviations from the mean value of 12.3% and 10% of the measured ratio.
Prentice, Boone M; Chumbley, Chad W; Hachey, Brian C; Norris, Jeremy L; Caprioli, Richard M
2016-10-04
Quantitative matrix-assisted laser desorption/ionization time-of-flight (MALDI TOF) approaches have historically suffered from poor accuracy and precision mainly due to the nonuniform distribution of matrix and analyte across the target surface, matrix interferences, and ionization suppression. Tandem mass spectrometry (MS/MS) can be used to ensure chemical specificity as well as improve signal-to-noise ratios by eliminating interferences from chemical noise, alleviating some concerns about dynamic range. However, conventional MALDI TOF/TOF modalities typically only scan for a single MS/MS event per laser shot, and multiplex assays require sequential analyses. We describe here new methodology that allows for multiple TOF/TOF fragmentation events to be performed in a single laser shot. This technology allows the reference of analyte intensity to that of the internal standard in each laser shot, even when the analyte and internal standard are quite disparate in m/z, thereby improving quantification while maintaining chemical specificity and duty cycle. In the quantitative analysis of the drug enalapril in pooled human plasma with ramipril as an internal standard, a greater than 4-fold improvement in relative standard deviation (<10%) was observed as well as improved coefficients of determination (R 2 ) and accuracy (>85% quality controls). Using this approach we have also performed simultaneous quantitative analysis of three drugs (promethazine, enalapril, and verapamil) using deuterated analogues of these drugs as internal standards.
75 FR 21777 - Regulatory Agenda
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-26
... flexibility analyses: Energy Efficiency Standards for Pool Heaters and Direct Heating Equipment and Water... Heaters and Direct Heating Equipment and Water 1904-AA90 Heaters 119 Test Procedures for Walk-In Coolers... Renewable Energy (EE) 118. ENERGY EFFICIENCY STANDARDS FOR POOL HEATERS AND DIRECT HEATING EQUIPMENT AND...
Department of Energy Semiannual Regulatory Agenda
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-26
...: Energy Efficiency Standards for Pool Heaters and Direct Heating Equipment and Water Heaters, and Test... EFFICIENCY STANDARDS FOR POOL HEATERS AND DIRECT HEATING EQUIPMENT AND WATER HEATERS Legal Authority: 42 USC... and direct heating equipment. This is the second review for water heaters. Timetable: Action Date FR...
Comparative study of navigated versus freehand osteochondral graft transplantation of the knee.
Koulalis, Dimitrios; Di Benedetto, Paolo; Citak, Mustafa; O'Loughlin, Padhraig; Pearle, Andrew D; Kendoff, Daniel O
2009-04-01
Osteochondral lesions are a common sports-related injury for which osteochondral grafting, including mosaicplasty, is an established treatment. Computer navigation has been gaining popularity in orthopaedic surgery to improve accuracy and precision. Navigation improves angle and depth matching during harvest and placement of osteochondral grafts compared with conventional freehand open technique. Controlled laboratory study. Three cadaveric knees were used. Reference markers were attached to the femur, tibia, and donor/recipient site guides. Fifteen osteochondral grafts were harvested and inserted into recipient sites with computer navigation, and 15 similar grafts were inserted freehand. The angles of graft removal and placement as well as surface congruity (graft depth) were calculated for each surgical group. The mean harvesting angle at the donor site using navigation was 4 degrees (standard deviation, 2.3 degrees ; range, 1 degrees -9 degrees ) versus 12 degrees (standard deviation, 5.5 degrees ; range, 5 degrees -24 degrees ) using freehand technique (P < .0001). The recipient plug removal angle using the navigated technique was 3.3 degrees (standard deviation, 2.1 degrees ; range, 0 degrees -9 degrees ) versus 10.7 degrees (standard deviation, 4.9 degrees ; range, 2 degrees -17 degrees ) in freehand (P < .0001). The mean navigated recipient plug placement angle was 3.6 degrees (standard deviation, 2.0 degrees ; range, 1 degrees -9 degrees ) versus 10.6 degrees (standard deviation, 4.4 degrees ; range, 3 degrees -17 degrees ) with freehand technique (P = .0001). The mean height of plug protrusion under navigation was 0.3 mm (standard deviation, 0.2 mm; range, 0-0.6 mm) versus 0.5 mm (standard deviation, 0.3 mm; range, 0.2-1.1 mm) using a freehand technique (P = .0034). Significantly greater accuracy and precision were observed in harvesting and placement of the osteochondral grafts in the navigated procedures. Clinical studies are needed to establish a benefit in vivo. Improvement in the osteochondral harvest and placement is desirable to optimize clinical outcomes. Navigation shows great potential to improve both harvest and placement precision and accuracy, thus optimizing ultimate surface congruity.
Haff, Nancy; Patel, Mitesh S; Lim, Raymond; Zhu, Jingsan; Troxel, Andrea B; Asch, David A; Volpp, Kevin G
2015-01-01
To evaluate the use of behavioral economics to design financial incentives to promote health behavior change and to explore associations with demographic characteristics. Studies performed by the Center for Health Incentives and Behavioral Economics at the University of Pennsylvania published between January 2006 and March 2014. Randomized, controlled trials with available participant-level data. Studies that did not use financial incentives to promote health behavior change were excluded. Participant-level data from seven studies were pooled. Meta-analysis on the pooled sample using a random-effects model with interaction terms to examine treatment effects and whether they varied by incentive structure or demographic characteristics. The pooled study sample comprised 1403 participants, of whom 35% were female, 70% were white, 24% were black, and the mean age was 48 years (standard deviation 11.2 years). In the fully adjusted model, participants offered financial incentives had higher odds of behavior change (odds ratio [OR]: 3.96; p < .01) when compared to control. There were no significant interactions between financial incentives and gender, age, race, income, or education. When further adjusting for incentive structure, blacks had higher odds than whites of achieving behavior change (OR: 1.67; p < .05) with a conditional payment. Compared to lower-income participants, higher-income participants had lower odds of behavior change (OR: 0.46; p = .01) with a regret lottery. Financial incentives designed using concepts from behavioral economics were effective for promoting health behavior change. There were no large and consistent relationships between the effectiveness of financial incentives and observable demographic characteristics. Second-order examinations of incentive structure suggest potential relationships among the effectiveness of financial incentives, incentive structure, and the demographic characteristics of race and income.
Cohen, Stephen M; Vogel, Jon D; Marcet, Jorge E; Candiotti, Keith A
2014-01-01
Postsurgical pain management remains a significant challenge. Liposome bupivacaine, as part of a multimodal analgesic regimen, has been shown to significantly reduce postsurgical opioid consumption, hospital length of stay (LOS), and hospitalization costs in gastrointestinal (GI) surgery, compared with intravenous (IV) opioid-based patient-controlled analgesia (PCA). Pooled results from open-label studies comparing a liposome bupivacaine-based multimodal analgesic regimen with IV opioid PCA were analyzed. Patients (n=191) who underwent planned surgery and received study drug (IV opioid PCA, n=105; multimodal analgesia, n=86) were included. Liposome bupivacaine-based multimodal analgesia compared with IV opioid PCA significantly reduced mean (standard deviation [SD]) postsurgical opioid consumption (38 [55] mg versus [vs] 96 [85] mg; P<0.0001), postsurgical LOS (median 2.9 vs 4.3 days; P<0.0001), and mean hospitalization costs (US$8,271 vs US$10,726; P=0.0109). The multimodal analgesia group reported significantly fewer patients with opioid-related adverse events (AEs) than the IV opioid PCA group (P=0.0027); there were no significant between-group differences in patient satisfaction scores at 30 days. A liposome bupivacaine-based multimodal analgesic regimen was associated with significantly less opioid consumption, opioid-related AEs, and better health economic outcomes compared with an IV opioid PCA-based regimen in patients undergoing GI surgery. This pooled analysis is based on data from Phase IV clinical trials registered on the US National Institutes of Health www.ClinicalTrials.gov database under study identifiers NCT01460485, NCT01507220, NCT01507233, NCT01509638, NCT01509807, NCT01509820, NCT01461122, NCT01461135, NCT01534988, and NCT01507246.
Colegrave, Nick
2017-01-01
A common approach to the analysis of experimental data across much of the biological sciences is test-qualified pooling. Here non-significant terms are dropped from a statistical model, effectively pooling the variation associated with each removed term with the error term used to test hypotheses (or estimate effect sizes). This pooling is only carried out if statistical testing on the basis of applying that data to a previous more complicated model provides motivation for this model simplification; hence the pooling is test-qualified. In pooling, the researcher increases the degrees of freedom of the error term with the aim of increasing statistical power to test their hypotheses of interest. Despite this approach being widely adopted and explicitly recommended by some of the most widely cited statistical textbooks aimed at biologists, here we argue that (except in highly specialized circumstances that we can identify) the hoped-for improvement in statistical power will be small or non-existent, and there is likely to be much reduced reliability of the statistical procedures through deviation of type I error rates from nominal levels. We thus call for greatly reduced use of test-qualified pooling across experimental biology, more careful justification of any use that continues, and a different philosophy for initial selection of statistical models in the light of this change in procedure. PMID:28330912
NASA Astrophysics Data System (ADS)
Stock, Michael; Barat, Pauline; Davis, Richard S.; Picard, Alain; Milton, Martin J. T.
2015-04-01
This report presents the results of the first phase of the campaign of calibration carried out with respect to the international prototype of the kilogram (IPK) in anticipation of the redefinition of the kilogram (Extraordinary Calibrations). The definition of the kilogram was realized according to the procedure outlined in the 8th Edition of the SI Brochure. Thus the IPK and its six official copies have been cleaned and washed following the BIPM procedure. The mass comparisons carried out during this campaign showed a very good repeatability. The pooled standard deviation of repeated weighings of the prototypes was 0.4 µg. The effect of cleaning and washing of the IPK was to remove a mass of 16.8 µg. The effect of cleaning and washing of the six official copies was found to be very similar, giving an average mass removed from the seven prototypes of 15 µg with a standard deviation of 2 µg. The differences in mass between the IPK and the official copies have changed by an average of 1 µg since the 3rd Periodic Verification of National Prototypes of the Kilogram (1988-1992). These results do not confirm the trend for the masses of the six official copies to diverge from the mass of the IPK that was observed during the 2nd and 3rd Periodic Verifications. All BIPM working standards and the prototypes reserved for special use have been calibrated with respect to the IPK as part of this campaign. All of them were found to have lower masses than when they were calibrated during the 3rd Periodic Verification. As a consequence, the BIPM ‘as-maintained’ mass unit in 2014 has been found to be offset by 35 µg with respect to the IPK. This result will be analyzed in a further publication.
Matrix Summaries Improve Research Reports: Secondary Analyses Using Published Literature
ERIC Educational Resources Information Center
Zientek, Linda Reichwein; Thompson, Bruce
2009-01-01
Correlation matrices and standard deviations are the building blocks of many of the commonly conducted analyses in published research, and AERA and APA reporting standards recommend their inclusion when reporting research results. The authors argue that the inclusion of correlation/covariance matrices, standard deviations, and means can enhance…
30 CFR 74.8 - Measurement, accuracy, and reliability requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... concentration, as defined by the relative standard deviation of the distribution of measurements. The relative standard deviation shall be less than 0.1275 without bias for both full-shift measurements of 8 hours or... Standards, Regulations, and Variances, 1100 Wilson Boulevard, Room 2350, Arlington, Virginia 22209-3939...
NASA Astrophysics Data System (ADS)
Campo-Bescós, M. A.; Flores-Cervantes, J. H.; Bras, R. L.; Casalí, J.; Giráldez, J. V.
2013-12-01
large fraction of soil erosion in temperate climate systems proceeds from gully headcut growth processes. Nevertheless, headcut retreat is not well understood. Few erosion models include gully headcut growth processes, and none of the existing headcut retreat models have been tested against long-term retreat rate estimates. In this work the headcut retreat resulting from plunge pool erosion in the Channel Hillslope Integrated Landscape Development (CHILD) model is calibrated and compared to long-term evolution measurements of six gullies at the Bardenas Reales, northeast Spain. The headcut retreat module of CHILD was calibrated by adjusting the shape factor parameter to fit the observed retreat and volumetric soil loss of one gully during a 36 year period, using reported and collected field data to parameterize the rest of the model. To test the calibrated model, estimates by CHILD were compared to observations of headcut retreat from five other neighboring gullies. The differences in volumetric soil loss rates between the simulations and observations were less than 0.05 m3 yr-1, on average, with standard deviations smaller than 0.35 m3 yr-1. These results are the first evaluation of the headcut retreat module implemented in CHILD with a field data set. These results also show the usefulness of the model as a tool for simulating long-term volumetric gully evolution due to plunge pool erosion.
Salt fluoridation: a meta-analysis of its efficacy for caries prevention.
Yengopal, V; Chikte, U M E; Mickenautsch, S; Oliveira, L B; Bhayat, A
2010-03-01
The aim of this meta-analysis was to assess the caries preventive effect of Salt fluoridation (SF) in the permanent dentition in children. THE OBJECTIVES WERE TO COMPARE: (1) the caries preventive effects of SF versus no exposure in different age cohorts (6-8; 9-12; and 13-15 years old); (2) SF versus other community based interventions (milk or water fluoridation [WF]). 9 English and 2 non-English databases were searched for papers that reported on the caries preventive effect of groups (with controls) that were exposed to SF in the form of mean DMFT scores with standard deviations. Differences in exposed and nonexposed groups were computed on the basis of weighted mean differences (WMDs) with 95% confidence intervals (CIs). For 6-8 year olds, the pooled reduction in DMFT scores was -0.98 [95% CI: -1.68 to -0.29]; for 9-12 year olds, it was -2.13 [95% CI: -2.55 to -1.70] and for the 13-15 year old groups, -4.22 [95% CI: -6.84 to -1.55]. All the analyses favoured the SF groups (p <0.001). For SF versus WF, there was no difference (-0.11 reduction [95% CI: -0.29 to +0.07]). Within limitations, the pooled estimates of the WMDs for the different age cohorts favoured SF versus no exposure.
Depression and Oxidative Stress: Results From a Meta-Analysis of Observational Studies
Palta, Priya; Samuel, Laura J.; Miller, Edgar R.; Szanton, Sarah L.
2014-01-01
Objective To perform a systematic review and meta-analysis that quantitatively tests and summarizes the hypothesis that depression results in elevated oxidative stress and lower antioxidant levels. Methods We performed a meta-analysis of studies that reported an association between depression and oxidative stress and/or antioxidant status markers. PubMed and EMBASE databases were searched for articles published from January 1980 through December 2012. A random-effects model, weighted by inverse variance, was performed to pool standard deviation (Cohen’s d) effect size estimates across studies for oxidative stress and antioxidant status measures, separately. Results Twenty-three studies with 4980 participants were included in the meta-analysis. Depression was most commonly measured using the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition criteria. A Cohen’s d effect size of 0.55 (95% confidence interval = 0.47–0.63) was found for the association between depression and oxidative stress, indicating a roughly 0.55 of 1-standard-deviation increase in oxidative stress among individuals with depression compared with those without depression. The results of the studies displayed significant heterogeneity (I2 = 80.0%, p < .001). A statistically significant effect was also observed for the association between depression and antioxidant status markers (Cohen’s d = −0.24, 95% confidence interval = −0.33 to −0.15). Conclusions This meta-analysis observed an association between depression and oxidative stress and antioxidant status across many different studies. Differences in measures of depression and markers of oxidative stress and antioxidant status markers could account for the observed heterogeneity. These findings suggest that well-established associations between depression and poor heath outcomes may be mediated by high oxidative stress. PMID:24336428
Depression and oxidative stress: results from a meta-analysis of observational studies.
Palta, Priya; Samuel, Laura J; Miller, Edgar R; Szanton, Sarah L
2014-01-01
To perform a systematic review and meta-analysis that quantitatively tests and summarizes the hypothesis that depression results in elevated oxidative stress and lower antioxidant levels. We performed a meta-analysis of studies that reported an association between depression and oxidative stress and/or antioxidant status markers. PubMed and EMBASE databases were searched for articles published from January 1980 through December 2012. A random-effects model, weighted by inverse variance, was performed to pool standard deviation (Cohen's d) effect size estimates across studies for oxidative stress and antioxidant status measures, separately. Twenty-three studies with 4980 participants were included in the meta-analysis. Depression was most commonly measured using the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition criteria. A Cohen's d effect size of 0.55 (95% confidence interval = 0.47-0.63) was found for the association between depression and oxidative stress, indicating a roughly 0.55 of 1-standard-deviation increase in oxidative stress among individuals with depression compared with those without depression. The results of the studies displayed significant heterogeneity (I(2) = 80.0%, p < .001). A statistically significant effect was also observed for the association between depression and antioxidant status markers (Cohen's d = -0.24, 95% confidence interval = -0.33 to -0.15). This meta-analysis observed an association between depression and oxidative stress and antioxidant status across many different studies. Differences in measures of depression and markers of oxidative stress and antioxidant status markers could account for the observed heterogeneity. These findings suggest that well-established associations between depression and poor heath outcomes may be mediated by high oxidative stress.
Pagel, Tobias; Franklin, Jeremy; Baethge, Christopher
2014-03-01
Schizoaffective disorder is viewed as a heterogeneous diagnosis among psychotic illnesses. Different diagnostic systems differ in their definition with DSM (-IIIR, -IV, and -V) providing a narrower definition than RDC and ICD-10. It is unclear whether this difference is reflected in patient samples diagnosed according to different diagnostic systems. Exploratory study based on a systematic review of studies of schizoaffective disorder samples diagnosed by either RDC and ICD-10 (group of "broad criteria") or DSM-IIIR and -IV ("narrow criteria"); comparison (by Mann-Whitney-U-tests) of key characteristics, such as age, number of hospitalizations, or scores in psychometric tests, between more broadly and more narrowly defined schizoaffective disorder samples using standard deviations as a measurement of heterogeneity as well as weighted means and percentages. To reduce selection bias only studies including schizoaffective patient samples together with affective disorder and schizophrenia samples were selected. 55 studies were included, 14 employing RDC, 4 ICD-10, 20 DSM-IIIR, and 17 DSM-IV. Thirteen characteristics were compared: patients diagnosed according to broader criteria had fewer previous hospitalizations (2.2 vs. 5.4) and were both less often male (42 vs. 51%) and married (21 vs. 40%). Heterogeneity was similar in both groups but slightly higher in RDC and ICD-10 samples than in DSM-IIIR and -IV-samples: +4% regarding demographic and clinical course data and +13% regarding psychometric tests (pooled SD). Secular trends and different designs may have confounded the results and limit generalizability. Some comparisons were underpowered. Differences in diagnostic criteria are reflected in key characteristics of samples. The association of larger heterogeneity with wider diagnostic criteria supports employing standard deviations as a measurement of heterogeneity. Copyright © 2013 Elsevier B.V. All rights reserved.
The effects of auditory stimulation with music on heart rate variability in healthy women.
Roque, Adriano L; Valenti, Vitor E; Guida, Heraldo L; Campos, Mônica F; Knap, André; Vanderlei, Luiz Carlos M; Ferreira, Lucas L; Ferreira, Celso; Abreu, Luiz Carlos de
2013-07-01
There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21), who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19), who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB). A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB). The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio), low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. The triangular index and the standard deviation of the long-term RR interval indices were reduced during exposure to both music styles in the first group and tended to decrease in the second group whereas the white noise exposure decreased the high frequency index. We observed no changes regarding the triangular interpolation of RR intervals, standard deviation of instantaneous beat-by-beat variability and standard deviation of instantaneous beat-by-beat variability/standard deviation in the long-term RR interval ratio. We suggest that relaxant baroque and excitatory heavy metal music slightly decrease global heart rate variability because of the equivalent sound level.
The effects of auditory stimulation with music on heart rate variability in healthy women
Roque, Adriano L.; Valenti, Vitor E.; Guida, Heraldo L.; Campos, Mônica F.; Knap, André; Vanderlei, Luiz Carlos M.; Ferreira, Lucas L.; Ferreira, Celso; de Abreu, Luiz Carlos
2013-01-01
OBJECTIVES: There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. METHODS: We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21), who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19), who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB). A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB). The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio), low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. RESULTS: The triangular index and the standard deviation of the long-term RR interval indices were reduced during exposure to both music styles in the first group and tended to decrease in the second group whereas the white noise exposure decreased the high frequency index. We observed no changes regarding the triangular interpolation of RR intervals, standard deviation of instantaneous beat-by-beat variability and standard deviation of instantaneous beat-by-beat variability/standard deviation in the long-term RR interval ratio. CONCLUSION: We suggest that relaxant baroque and excitatory heavy metal music slightly decrease global heart rate variability because of the equivalent sound level. PMID:23917660
USL/DBMS NASA/PC R and D project C programming standards
NASA Technical Reports Server (NTRS)
Dominick, Wayne D. (Editor); Moreau, Dennis R.
1984-01-01
A set of programming standards intended to promote reliability, readability, and portability of C programs written for PC research and development projects is established. These standards must be adhered to except where reasons for deviation are clearly identified and approved by the PC team. Any approved deviation from these standards must also be clearly documented in the pertinent source code.
Tucker, Jalie A.; Roth, David L.; Vignolo, Mary J.; Westfall, Andrew O.
2014-01-01
Data were pooled from three studies of recently resolved community-dwelling problem drinkers to determine whether a behavioral economic index of the value of rewards available over different time horizons distinguished among moderation (n = 30), abstinent (n = 95), and unresolved (n = 77) outcomes. Moderation over 1-2 year prospective follow-up intervals was hypothesized to involve longer term behavior regulation processes compared to abstinence or relapse and to be predicted by more balanced pre-resolution monetary allocations between short- and longer-term objectives (i.e., drinking and saving for the future). Standardized odds ratios (OR) based on changes in standard deviation units from a multinomial logistic regression indicated that increases on this “Alcohol-Savings Discretionary Expenditure” index predicted higher rates of both abstinence (OR = 1.93, p = .004) and relapse (OR = 2.89, p < .0001) compared to moderation outcomes. The index had incremental utility in predicting moderation in complex models that included other established predictors. The study adds to evidence supporting a behavioral economic analysis of drinking resolutions and shows that a systematic analysis of pre-resolution spending patterns aids in predicting moderation. PMID:19309182
Ran, Yang; Su, Rongtao; Ma, Pengfei; Wang, Xiaolin; Zhou, Pu; Si, Lei
2016-05-10
We present a new quantitative index of standard deviation to measure the homogeneity of spectral lines in a fiber amplifier system so as to find the relation between the stimulated Brillouin scattering (SBS) threshold and the homogeneity of the corresponding spectral lines. A theoretical model is built and a simulation framework has been established to estimate the SBS threshold when input spectra with different homogeneities are set. In our experiment, by setting the phase modulation voltage to a constant value and the modulation frequency to different values, spectral lines with different homogeneities can be obtained. The experimental results show that the SBS threshold increases negatively with the standard deviation of the modulated spectrum, which is in good agreement with the theoretical results. When the phase modulation voltage is confined to 10 V and the modulation frequency is set to 80 MHz, the standard deviation of the modulated spectrum equals 0.0051, which is the lowest value in our experiment. Thus, at this time, the highest SBS threshold has been achieved. This standard deviation can be a good quantitative index in evaluating the power scaling potential in a fiber amplifier system, which is also a design guideline in suppressing the SBS to a better degree.
NetCDF file of the SREF standard deviation of wind speed and direction that was used to inject variability in the FDDA input.variable U_NDG_OLD contains standard deviation of wind speed (m/s)variable V_NDG_OLD contains the standard deviation of wind direction (deg)This dataset is associated with the following publication:Gilliam , R., C. Hogrefe , J. Godowitch, S. Napelenok , R. Mathur , and S.T. Rao. Impact of inherent meteorology uncertainty on air quality model predictions. JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES. American Geophysical Union, Washington, DC, USA, 120(23): 12,259–12,280, (2015).
Hardman, John; Al-Hadithy, Nawfal; Hester, Thomas; Anakwe, Raymond
2015-12-01
There remains little consensus regarding the optimal management of distal radius fractures. Fixed angle volar devices have gained recent popularity, but have also been associated with soft tissue complications. Intramedullary (IM) devices offer fixed angle stabilisation with minimally invasive surgical technique and low, IM profile. No formal review of outcomes could be identified. We conducted a systematic review of clinical studies regarding the use of fixed angle IM devices in acute extra-articular or simple intra-articular distal radius fractures. Preferred Reporting Items for Systematic Reviews (PRISMA) guidance was followed. Numerical data regarding functional scores, ranges of movement, radiological outcomes and complications were pooled to produce aggregate means and standard deviation. A total of 310 titles and abstracts were identified. Fourteen papers remained for analysis. Total patient number was 357, mean age 63.72 years and mean follow-up 12.77 months. Mean functional scores were all rated as 'excellent'. Aggregate means: flexion 53.62°, extension 56.38°, pronation 69.10°, supination 70.29°, ulnar deviation 28.35°, radial deviation 18.12°, radial height 8.98 mm, radial inclination 16.51°, volar tilt 5.35°, ulnar variance 0.66 mm and grip strength 90.37 %. Overall complication rate was 19.6 %. Tendon rupture was unreported. Tendon irritation was 0.88 %. Radial nerve paraesthesia was 11.44 %. Fixed angle IM devices facilitate excellent functional outcomes, with radiological and clinical parameters at least equivalent to volar plate devices. Low rates of tendon irritation and absence of tendon rupture are advantageous. Significant limitations include a lack of application for complex articular injuries and the propensity to cause a transient neuritis of the superficial branch of the radial nerve.
75 FR 67093 - Iceberg Water Deviating From Identity Standard; Temporary Permit for Market Testing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-01
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0517] Iceberg Water Deviating From Identity Standard; Temporary Permit for Market Testing AGENCY: Food and Drug... from the requirements of the standards of identity issued under section 401 of the Federal Food, Drug...
78 FR 2273 - Canned Tuna Deviating From Identity Standard; Temporary Permit for Market Testing
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-10
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-P-1189] Canned Tuna Deviating From Identity Standard; Temporary Permit for Market Testing AGENCY: Food and Drug... interstate shipment of experimental packs of food varying from the requirements of standards of identity...
Upgraded FAA Airfield Capacity Model. Volume 2. Technical Description of Revisions
1981-02-01
the threshold t k a the time at which departure k is released FIGURE 3-1 TIME AXIS DIAGRAM OF SINGLE RUNWAY OPERATIONS 3-2 J"- SIGMAR the standard...standard deviation of the interarrival time. SIGMAR - the standard deviation of the arrival runway occupancy time. A-5 SINGLE - program subroutine for
Methods of editing cloud and atmospheric layer affected pixels from satellite data
NASA Technical Reports Server (NTRS)
Nixon, P. R.; Wiegand, C. L.; Richardson, A. J.; Johnson, M. P. (Principal Investigator)
1982-01-01
Subvisible cirrus clouds (SCi) were easily distinguished in mid-infrared (MIR) TIROS-N daytime data from south Texas and northeast Mexico. The MIR (3.55-3.93 micrometer) pixel digital count means of the SCi affected areas were more than 3.5 standard deviations on the cold side of the scene means. (These standard deviations were made free of the effects of unusual instrument error by factoring out the Ch 3 MIR noise on the basis of detailed examination of noisy and noise-free pixels). SCi affected areas in the IR Ch 4 (10.5-11.5 micrometer) appeared cooler than the general scene, but were not as prominent as in Ch 3, being less than 2 standard deviations from the scene mean. Ch 3 and 4 standard deviations and coefficients of variation are not reliable indicators, by themselves, of the presence of SCi because land features can have similar statistical properties.
A Taxonomy of Delivery and Documentation Deviations During Delivery of High-Fidelity Simulations.
McIvor, William R; Banerjee, Arna; Boulet, John R; Bekhuis, Tanja; Tseytlin, Eugene; Torsher, Laurence; DeMaria, Samuel; Rask, John P; Shotwell, Matthew S; Burden, Amanda; Cooper, Jeffrey B; Gaba, David M; Levine, Adam; Park, Christine; Sinz, Elizabeth; Steadman, Randolph H; Weinger, Matthew B
2017-02-01
We developed a taxonomy of simulation delivery and documentation deviations noted during a multicenter, high-fidelity simulation trial that was conducted to assess practicing physicians' performance. Eight simulation centers sought to implement standardized scenarios over 2 years. Rules, guidelines, and detailed scenario scripts were established to facilitate reproducible scenario delivery; however, pilot trials revealed deviations from those rubrics. A taxonomy with hierarchically arranged terms that define a lack of standardization of simulation scenario delivery was then created to aid educators and researchers in assessing and describing their ability to reproducibly conduct simulations. Thirty-six types of delivery or documentation deviations were identified from the scenario scripts and study rules. Using a Delphi technique and open card sorting, simulation experts formulated a taxonomy of high-fidelity simulation execution and documentation deviations. The taxonomy was iteratively refined and then tested by 2 investigators not involved with its development. The taxonomy has 2 main classes, simulation center deviation and participant deviation, which are further subdivided into as many as 6 subclasses. Inter-rater classification agreement using the taxonomy was 74% or greater for each of the 7 levels of its hierarchy. Cohen kappa calculations confirmed substantial agreement beyond that expected by chance. All deviations were classified within the taxonomy. This is a useful taxonomy that standardizes terms for simulation delivery and documentation deviations, facilitates quality assurance in scenario delivery, and enables quantification of the impact of deviations upon simulation-based performance assessment.
Kwon, Deukwoo; Reis, Isildinha M
2015-08-12
When conducting a meta-analysis of a continuous outcome, estimated means and standard deviations from the selected studies are required in order to obtain an overall estimate of the mean effect and its confidence interval. If these quantities are not directly reported in the publications, they must be estimated from other reported summary statistics, such as the median, the minimum, the maximum, and quartiles. We propose a simulation-based estimation approach using the Approximate Bayesian Computation (ABC) technique for estimating mean and standard deviation based on various sets of summary statistics found in published studies. We conduct a simulation study to compare the proposed ABC method with the existing methods of Hozo et al. (2005), Bland (2015), and Wan et al. (2014). In the estimation of the standard deviation, our ABC method performs better than the other methods when data are generated from skewed or heavy-tailed distributions. The corresponding average relative error (ARE) approaches zero as sample size increases. In data generated from the normal distribution, our ABC performs well. However, the Wan et al. method is best for estimating standard deviation under normal distribution. In the estimation of the mean, our ABC method is best regardless of assumed distribution. ABC is a flexible method for estimating the study-specific mean and standard deviation for meta-analysis, especially with underlying skewed or heavy-tailed distributions. The ABC method can be applied using other reported summary statistics such as the posterior mean and 95 % credible interval when Bayesian analysis has been employed.
48 CFR 9904.410-63 - Effective date.
Code of Federal Regulations, 2014 CFR
2014-10-01
...: (a) Contract I—Since Contract I was in existence prior to January 1, 1978, the G&A expense pool shall... this contract was in existence prior to January 1, 1978, the G&A expense pool shall be allocated to it... Standard's applicability upon receipt of a contract to which this Standard is applicable. For contractors...
48 CFR 9904.410-63 - Effective date.
Code of Federal Regulations, 2012 CFR
2012-10-01
...: (a) Contract I—Since Contract I was in existence prior to January 1, 1978, the G&A expense pool shall... this contract was in existence prior to January 1, 1978, the G&A expense pool shall be allocated to it... Standard's applicability upon receipt of a contract to which this Standard is applicable. For contractors...
On Teaching about the Coefficient of Variation in Introductory Statistics Courses
ERIC Educational Resources Information Center
Trafimow, David
2014-01-01
The standard deviation is related to the mean by virtue of the coefficient of variation. Teachers of statistics courses can make use of that fact to make the standard deviation more comprehensible for statistics students.
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARD FOR SWIMMING POOL SLIDES § 1207.12 Stockpiling. (a) Definitions. As used in this section: (1) Stockpiling means manufacturing or importing swimming pool slides between the date of promulgation of part... importation) means the total number of swimming pool slides manufactured (or imported) during a stated time...
A SIMPLE METHOD FOR EVALUATING DATA FROM AN INTERLABORATORY STUDY
Large-scale laboratory-and method-performance studies involving more than about 30 laboratories may be evaluated by calculating the HORRAT ratio for each test sample (HORRAT=[experimentally found among-laboratories relative standard deviation] divided by [relative standard deviat...
Morikawa, Kei; Kurimoto, Noriaki; Inoue, Takeo; Mineshita, Masamichi; Miyazawa, Teruomi
2015-01-01
Endobronchial ultrasonography using a guide sheath (EBUS-GS) is an increasingly common bronchoscopic technique, but currently, no methods have been established to quantitatively evaluate EBUS images of peripheral pulmonary lesions. The purpose of this study was to evaluate whether histogram data collected from EBUS-GS images can contribute to the diagnosis of lung cancer. Histogram-based analyses focusing on the brightness of EBUS images were retrospectively conducted: 60 patients (38 lung cancer; 22 inflammatory diseases), with clear EBUS images were included. For each patient, a 400-pixel region of interest was selected, typically located at a 3- to 5-mm radius from the probe, from recorded EBUS images during bronchoscopy. Histogram height, width, height/width ratio, standard deviation, kurtosis and skewness were investigated as diagnostic indicators. Median histogram height, width, height/width ratio and standard deviation were significantly different between lung cancer and benign lesions (all p < 0.01). With a cutoff value for standard deviation of 10.5, lung cancer could be diagnosed with an accuracy of 81.7%. Other characteristics investigated were inferior when compared to histogram standard deviation. Histogram standard deviation appears to be the most useful characteristic for diagnosing lung cancer using EBUS images. © 2015 S. Karger AG, Basel.
Role of the standard deviation in the estimation of benchmark doses with continuous data.
Gaylor, David W; Slikker, William
2004-12-01
For continuous data, risk is defined here as the proportion of animals with values above a large percentile, e.g., the 99th percentile or below the 1st percentile, for the distribution of values among control animals. It is known that reducing the standard deviation of measurements through improved experimental techniques will result in less stringent (higher) doses for the lower confidence limit on the benchmark dose that is estimated to produce a specified risk of animals with abnormal levels for a biological effect. Thus, a somewhat larger (less stringent) lower confidence limit is obtained that may be used as a point of departure for low-dose risk assessment. It is shown in this article that it is important for the benchmark dose to be based primarily on the standard deviation among animals, s(a), apart from the standard deviation of measurement errors, s(m), within animals. If the benchmark dose is incorrectly based on the overall standard deviation among average values for animals, which includes measurement error variation, the benchmark dose will be overestimated and the risk will be underestimated. The bias increases as s(m) increases relative to s(a). The bias is relatively small if s(m) is less than one-third of s(a), a condition achieved in most experimental designs.
Statistical models for estimating daily streamflow in Michigan
Holtschlag, D.J.; Salehi, Habib
1992-01-01
Statistical models for estimating daily streamflow were analyzed for 25 pairs of streamflow-gaging stations in Michigan. Stations were paired by randomly choosing a station operated in 1989 at which 10 or more years of continuous flow data had been collected and at which flow is virtually unregulated; a nearby station was chosen where flow characteristics are similar. Streamflow data from the 25 randomly selected stations were used as the response variables; streamflow data at the nearby stations were used to generate a set of explanatory variables. Ordinary-least squares regression (OLSR) equations, autoregressive integrated moving-average (ARIMA) equations, and transfer function-noise (TFN) equations were developed to estimate the log transform of flow for the 25 randomly selected stations. The precision of each type of equation was evaluated on the basis of the standard deviation of the estimation errors. OLSR equations produce one set of estimation errors; ARIMA and TFN models each produce l sets of estimation errors corresponding to the forecast lead. The lead-l forecast is the estimate of flow l days ahead of the most recent streamflow used as a response variable in the estimation. In this analysis, the standard deviation of lead l ARIMA and TFN forecast errors were generally lower than the standard deviation of OLSR errors for l < 2 days and l < 9 days, respectively. Composite estimates were computed as a weighted average of forecasts based on TFN equations and backcasts (forecasts of the reverse-ordered series) based on ARIMA equations. The standard deviation of composite errors varied throughout the length of the estimation interval and generally was at maximum near the center of the interval. For comparison with OLSR errors, the mean standard deviation of composite errors were computed for intervals of length 1 to 40 days. The mean standard deviation of length-l composite errors were generally less than the standard deviation of the OLSR errors for l < 32 days. In addition, the composite estimates ensure a gradual transition between periods of estimated and measured flows. Model performance among stations of differing model error magnitudes were compared by computing ratios of the mean standard deviation of the length l composite errors to the standard deviation of OLSR errors. The mean error ratio for the set of 25 selected stations was less than 1 for intervals l < 32 days. Considering the frequency characteristics of the length of intervals of estimated record in Michigan, the effective mean error ratio for intervals < 30 days was 0.52. Thus, for intervals of estimation of 1 month or less, the error of the composite estimate is substantially lower than error of the OLSR estimate.
A Survey of Enzymatic Activity in Commercially Available Pool and Spa Products
USDA-ARS?s Scientific Manuscript database
Many pool water treatment products currently available commercially claim that they work effectively by possessing enzyme activity (specifically lipase) that degrades common oil (lipid) contaminants found in pool water. Currently, there is no standard in measuring the enzymatic activity of these enz...
Black, I; Seaton, R; Chackiath, S; Wagland, S T; Pollard, S J T; Longhurst, P J
2011-12-01
The identification of risk and its appropriate allocation to partners in project consortia is essential for minimizing overall project risks, ensuring timely delivery and maximizing benefit for money invested. Risk management guidance available from government bodies, especially in the UK, does not specify methodologies for quantitative risk assessment, nor does it offer a procedure for allocating risk among project partners. Here, a methodology to quantify project risk and potential approaches to allocating risk and their implications are discussed. Construction and operation of a waste management facility through a public-private finance contract are discussed. Public-private partnership contracts are special purpose vehicle (SPV) financing methods promoted by the UK government to boost private sector investment in facilities for public service enhancement. Our findings question the appropriateness of using standard deviation as a measure for project risk and confirm the concept of portfolio theory, suggesting the pooling of risk can reduce total risk and its impact.
How accurate is the Pearson r-from-Z approximation? A Monte Carlo simulation study.
Hittner, James B; May, Kim
2012-01-01
The Pearson r-from-Z approximation estimates the sample correlation (as an effect size measure) from the ratio of two quantities: the standard normal deviate equivalent (Z-score) corresponding to a one-tailed p-value divided by the square root of the total (pooled) sample size. The formula has utility in meta-analytic work when reports of research contain minimal statistical information. Although simple to implement, the accuracy of the Pearson r-from-Z approximation has not been empirically evaluated. To address this omission, we performed a series of Monte Carlo simulations. Results indicated that in some cases the formula did accurately estimate the sample correlation. However, when sample size was very small (N = 10) and effect sizes were small to small-moderate (ds of 0.1 and 0.3), the Pearson r-from-Z approximation was very inaccurate. Detailed figures that provide guidance as to when the Pearson r-from-Z formula will likely yield valid inferences are presented.
NASA Astrophysics Data System (ADS)
Young, Joseph Swyler
This thesis investigates the utility of lidar ceilometers, a type of aerosol lidar, in improving the understanding of meteorology and air quality in persistent wintertime stable boundary layers, or cold-air pools, that form in urbanized valley and basin topography. This thesis reviews the scientific literature to survey the present knowledge of persistent cold-air pools, the operating principles of lidar ceilometers, and their demonstrated utility in meteorological investigations. Lidar ceilometer data from the Persistent Cold-Air Pool Study (PCAPS) are then used with meteorological and air quality data from other in situ and remote sensing equipment to investigate cold-air pools that formed in Utah's Salt Lake Valley during the winter of 2010-2011. The lidar ceilometer is shown to accurately measure aerosol layer depth and aerosol loading, when compared to visual observations. A linear relationship is found between low-level lidar backscatter and surface particulate measurements. Convective boundary layer lidar analysis techniques applied to cold-air pool ceilometer profiles can detect useful layer characteristics. Fine-scale waves are observed and analyzed within the aerosol layer, with emphasis on Kelvin-Helmholz waves. Ceilometer aerosol backscatter profiles are analyzed to quantify and describe mixing processes in persistent cold-air pools. Overlays of other remote and in-situ observations are combined with ceilometer particle backscatter to describe specific events during PCAPS. This analysis describes the relationship between the aerosol layer and the valley inversion as well as interactions with large-scale meteorology. The ceilometer observations of hydrometers are used to quantify cloudiness and precipitation during the project, observing that 50% of hours when a PCAP was present had clouds or precipitation below 5 km above ground level (AGL). Then, combining an objective technique for determining hourly aerosol layer depths and correcting this subjectively during periods with low clouds or precipitation, a time series of aerosol depths was obtained. The mean depth of the surface-based aerosol layer during PCAP events was 1861 m MSL with a standard deviation of 135 m. The aerosol layer depth, given the approximate 1300 m altitude of the valley floor, is thus about 550 m, about 46% of the basin depth. The aerosol layer is present during much of the winter and is removed only during strong or prolonged precipitation periods or when surface winds are strong. Nocturnal fogs that formed near the end of high-stability PCAP episodes had a limited effect on aerosol layer depth. Aerosol layer depth was relatively invariant during the winter and during the persistent cold-air pools, while PM10 concentrations at the valley floor varied with bulk atmospheric stability associated primarily with passage of large-scale high- and low-pressure weather systems. PM10 concentrations also increased with cold-air pool duration. Mean aerosol loading in the surface-based aerosol layer, as determined from ceilometer backscatter coefficients, showed weaker variations than those of surface PM10 concentrations, suggesting that ineffective vertical mixing and aerosol layering are present in the cold-air pools. This is supported by higher time-resolution backscatter data, and it distinguishes the persistent cold-air pools from well-mixed convective boundary layers where ground-based air pollution concentrations are closely related to time-dependent convective boundary layer/aerosol depths. These results are discussed along with recommendations for future explorations of the ceilometer and cold-air pool topics.
Diatomite Type Filters for Swimming Pools. Standard No. 9, Revised October, 1966.
ERIC Educational Resources Information Center
National Sanitation Foundation, Ann Arbor, MI.
Pressure and vacuum diatomite type filters are covered in this standard. The filters herein described are intended to be designed and used specifically for swimming pool water filtration, both public and residential. Included are the basic components which are a necessary part of the diatomite type filter such as filter housing, element supports,…
Sand Type Filters for Swimming Pools. Standard No. 10, Revised October, 1966.
ERIC Educational Resources Information Center
National Sanitation Foundation, Ann Arbor, MI.
Sand type filters are covered in this standard. The filters described are intended to be designed and used specifically for swimming pool water filtration, both public and residential. Included are the basic components which are a necessary part of the sand type filter such as filter housing, upper and lower distribution systems filter media,…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-27
...EPA is approving into the Illinois State Implementation Plan (SIP) an adjusted standard for Royal Fiberglass Pools (``Royal'') at its Dix, Illinois facility. On November 8, 2010, the Illinois Environmental Protection Agency (IEPA) submitted to EPA for approval an adjustment to the general rule, Use of Organic Material Rule, commonly known as the eight pound per hour (8 lb/hr) rule, as it applies to emissions of volatile organic matter (VOM) from Royal's pool manufacturing facility. The adjusted standard relieves Royal from being subject to the general rule for VOM emissions from its Dix facility. EPA is approving this SIP revision because it will not interfere with attainment or maintenance of the ozone National Ambient Air Quality Standard (NAAQS).
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...
Santric-Milicevic, M; Vasic, V; Terzic-Supic, Z
2016-08-15
In times of austerity, the availability of econometric health knowledge assists policy-makers in understanding and balancing health expenditure with health care plans within fiscal constraints. The objective of this study is to explore whether the health workforce supply of the public health care sector, population number, and utilization of inpatient care significantly contribute to total health expenditure. The dependent variable is the total health expenditure (THE) in Serbia from the years 2003 to 2011. The independent variables are the number of health workers employed in the public health care sector, population number, and inpatient care discharges per 100 population. The statistical analyses include the quadratic interpolation method, natural logarithm and differentiation, and multiple linear regression analyses. The level of significance is set at P < 0.05. The regression model captures 90 % of all variations of observed dependent variables (adjusted R square), and the model is significant (P < 0.001). Total health expenditure increased by 1.21 standard deviations, with an increase in health workforce growth rate by 1 standard deviation. Furthermore, this rate decreased by 1.12 standard deviations, with an increase in (negative) population growth rate by 1 standard deviation. Finally, the growth rate increased by 0.38 standard deviation, with an increase of the growth rate of inpatient care discharges per 100 population by 1 standard deviation (P < 0.001). Study results demonstrate that the government has been making an effort to control strongly health budget growth. Exploring causality relationships between health expenditure and health workforce is important for countries that are trying to consolidate their public health finances and achieve universal health coverage at the same time.
NASA Technical Reports Server (NTRS)
1988-01-01
Caribbean Clear, Inc. used NASA's silver ion technology as a basis for its automatic pool purifier. System offers alternative approach to conventional purification chemicals. Caribbean Clear's principal markets are swimming pool owners who want to eliminate chlorine and bromine. Purifiers in Caribbean Clear System are same silver ions used in Apollo System to kill bacteria, plus copper ions to kill algae. They produce spa or pool water that exceeds EPA Standards for drinking water.
The truly remarkable universality of half a standard deviation: confirmation through another look.
Norman, Geoffrey R; Sloan, Jeff A; Wyrwich, Kathleen W
2004-10-01
In this issue of Expert Review of Pharmacoeconomics and Outcomes Research, Farivar, Liu, and Hays present their findings in 'Another look at the half standard deviation estimate of the minimally important difference in health-related quality of life scores (hereafter referred to as 'Another look') . These researchers have re-examined the May 2003 Medical Care article 'Interpretation of changes in health-related quality of life: the remarkable universality of half a standard deviation' (hereafter referred to as 'Remarkable') in the hope of supporting their hypothesis that the minimally important difference in health-related quality of life measures is undoubtedly closer to 0.3 standard deviations than 0.5. Nonetheless, despite their extensive wranglings with the exclusion of many articles that we included in our review; the inclusion of articles that we did not include in our review; and the recalculation of effect sizes using the absolute value of the mean differences, in our opinion, the results of the 'Another look' article confirm the same findings in the 'Remarkable' paper.
Rath, Animesha; Prusty, Manas R; Barik, Sushanta K; Das, Mumani; Tripathy, Hare K; Mahapatra, Namita; Hazra, Rupenangshu K
2017-01-01
Knowledge on prevalence of malaria vector species of a certain area provides important information for implementation of appropriate control strategies. The present study describes a rapid method for screening of major Anopheline vector species and at the same time detection of Plasmodium falciparum sporozoite infection and blood meal preferences/trophic preferences. The study was carried from February 2012 to March 2013 in three seasons, i.e. rainy, winter and summer in Jhumpura PHC of Keonjhar district, Odisha, India. Processing of mosquitoes was carried out in two different methods, viz. mosquito pool (P1) and mosquito DNA pool (P2). Pool size for both the methods was standardized for DNA isolation and multiplex PCR assay. This PCR based assay was employed to screen the major vector com- position in three different seasons of four different ecotypes of Keonjhar district. Pearson's correlation coefficient was determined for a comparative analysis of the morphological identification with the pool prevalence assay for each ecotype. A pool size of 10 was standardized for DNA isolation as well as PCR. PCR assay revealed that the average pool prevalence for all ecotypes was highest for An. annularis in winter and summer whereas for An. culicifacies it was rainy season. Foothill and plain ecotypes contributed to highest and lowest vectorial abundance respectively. The results of the prevalence of vector species in pool from PCR based assay were found to be highly correlated with that of the results of morphological identification. Screening by pool based PCR assay is relatively rapid as compared to conventional identification and can be employed as an important tool in malaria control programmes.
Static Scene Statistical Non-Uniformity Correction
2015-03-01
Error NUC Non-Uniformity Correction RMSE Root Mean Squared Error RSD Relative Standard Deviation S3NUC Static Scene Statistical Non-Uniformity...Deviation ( RSD ) which normalizes the standard deviation, σ, to the mean estimated value, µ using the equation RS D = σ µ × 100. The RSD plot of the gain...estimates is shown in Figure 4.1(b). The RSD plot shows that after a sample size of approximately 10, the different photocount values and the inclusion
Effect of multizone refractive multifocal contact lenses on standard automated perimetry.
Madrid-Costa, David; Ruiz-Alcocer, Javier; García-Lázaro, Santiago; Albarrán-Diego, César; Ferrer-Blasco, Teresa
2012-09-01
The aim of this study was to evaluate whether the creation of 2 foci (distance and near) provided by multizone refractive multifocal contact lenses (CLs) for presbyopia correction affects the measurements on Humphreys 24-2 Swedish interactive threshold algorithm (SITA) standard automated perimetry (SAP). In this crossover study, 30 subjects were fitted in random order with either a multifocal CL or a monofocal CL. After 1 month, a Humphrey 24-2 SITA standard strategy was performed. The visual field global indices (the mean deviation [MD] and pattern standard deviation [PSD]), reliability indices, test duration, and number of depressed points deviating at P<5%, P<2%, P<1%, and P<0.5% on pattern deviation probability plots were determined and compared between multifocal and monofocal CLs. Thirty eyes of 30 subjects were included in this study. There were no statistically significant differences in reliability indices or test duration. There was a statistically significant reduction in the MD with the multifocal CL compared with monfocal CL (P=0.001). Differences were not found in PSD nor in the number of depressed points deviating at P<5%, P<2%, P<1%, and P<0.5% in the pattern deviation probability maps studied. The results of this study suggest that the multizone refractive lens produces a generalized depression in threshold sensitivity as measured by the Humphreys 24-2 SITA SAP.
Stenzel, O; Wilbrandt, S; Wolf, J; Schürmann, M; Kaiser, N; Ristau, D; Ehlers, H; Carstens, F; Schippel, S; Mechold, L; Rauhut, R; Kennedy, M; Bischoff, M; Nowitzki, T; Zöller, A; Hagedorn, H; Reus, H; Hegemann, T; Starke, K; Harhausen, J; Foest, R; Schumacher, J
2017-02-01
Random effects in the repeatability of refractive index and absorption edge position of tantalum pentoxide layers prepared by plasma-ion-assisted electron-beam evaporation, ion beam sputtering, and magnetron sputtering are investigated and quantified. Standard deviations in refractive index between 4*10-4 and 4*10-3 have been obtained. Here, lowest standard deviations in refractive index close to our detection threshold could be achieved by both ion beam sputtering and plasma-ion-assisted deposition. In relation to the corresponding mean values, the standard deviations in band-edge position and refractive index are of similar order.
Closed-form confidence intervals for functions of the normal mean and standard deviation.
Donner, Allan; Zou, G Y
2012-08-01
Confidence interval methods for a normal mean and standard deviation are well known and simple to apply. However, the same cannot be said for important functions of these parameters. These functions include the normal distribution percentiles, the Bland-Altman limits of agreement, the coefficient of variation and Cohen's effect size. We present a simple approach to this problem by using variance estimates recovered from confidence limits computed for the mean and standard deviation separately. All resulting confidence intervals have closed forms. Simulation results demonstrate that this approach performs very well for limits of agreement, coefficients of variation and their differences.
McClure, Foster D; Lee, Jung K
2005-01-01
Sample size formulas are developed to estimate the repeatability and reproducibility standard deviations (Sr and S(R)) such that the actual error in (Sr and S(R)) relative to their respective true values, sigmar and sigmaR, are at predefined levels. The statistical consequences associated with AOAC INTERNATIONAL required sample size to validate an analytical method are discussed. In addition, formulas to estimate the uncertainties of (Sr and S(R)) were derived and are provided as supporting documentation. Formula for the Number of Replicates Required for a Specified Margin of Relative Error in the Estimate of the Repeatability Standard Deviation.
Pleil, Joachim D
2016-01-01
This commentary is the second of a series outlining one specific concept in interpreting biomarkers data. In the first, an observational method was presented for assessing the distribution of measurements before making parametric calculations. Here, the discussion revolves around the next step, the choice of using standard error of the mean or the calculated standard deviation to compare or predict measurement results.
Introducing the Mean Absolute Deviation "Effect" Size
ERIC Educational Resources Information Center
Gorard, Stephen
2015-01-01
This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…
Hopper, John L.
2015-01-01
How can the “strengths” of risk factors, in the sense of how well they discriminate cases from controls, be compared when they are measured on different scales such as continuous, binary, and integer? Given that risk estimates take into account other fitted and design-related factors—and that is how risk gradients are interpreted—so should the presentation of risk gradients. Therefore, for each risk factor X0, I propose using appropriate regression techniques to derive from appropriate population data the best fitting relationship between the mean of X0 and all the other covariates fitted in the model or adjusted for by design (X1, X2, … , Xn). The odds per adjusted standard deviation (OPERA) presents the risk association for X0 in terms of the change in risk per s = standard deviation of X0 adjusted for X1, X2, … , Xn, rather than the unadjusted standard deviation of X0 itself. If the increased risk is relative risk (RR)-fold over A adjusted standard deviations, then OPERA = exp[ln(RR)/A] = RRs. This unifying approach is illustrated by considering breast cancer and published risk estimates. OPERA estimates are by definition independent and can be used to compare the predictive strengths of risk factors across diseases and populations. PMID:26520360
NASA Astrophysics Data System (ADS)
Muji Susantoro, Tri; Wikantika, Ketut; Saepuloh, Asep; Handoyo Harsolumakso, Agus
2018-05-01
Selection of vegetation indices in plant mapping is needed to provide the best information of plant conditions. The methods used in this research are the standard deviation and the linear regression. This research tried to determine the vegetation indices used for mapping the sugarcane conditions around oil and gas fields. The data used in this study is Landsat 8 OLI/TIRS. The standard deviation analysis on the 23 vegetation indices with 27 samples has resulted in the six highest standard deviations of vegetation indices, termed as GRVI, SR, NLI, SIPI, GEMI and LAI. The standard deviation values are 0.47; 0.43; 0.30; 0.17; 0.16 and 0.13. Regression correlation analysis on the 23 vegetation indices with 280 samples has resulted in the six vegetation indices, termed as NDVI, ENDVI, GDVI, VARI, LAI and SIPI. This was performed based on regression correlation with the lowest value R2 than 0,8. The combined analysis of the standard deviation and the regression correlation has obtained the five vegetation indices, termed as NDVI, ENDVI, GDVI, LAI and SIPI. The results of the analysis of both methods show that a combination of two methods needs to be done to produce a good analysis of sugarcane conditions. It has been clarified through field surveys and showed good results for the prediction of microseepages.
The effects of demand uncertainty on strategic gaming in the merit-order electricity pool market
NASA Astrophysics Data System (ADS)
Frem, Bassam
In a merit-order electricity pool market, generating companies (Gencos) game with their offered incremental cost to meet the electricity demand and earn bigger market shares and higher profits. However when the demand is treated as a random variable instead of as a known constant, these Genco gaming strategies become more complex. After a brief introduction of electricity markets and gaming, the effects of demand uncertainty on strategic gaming are studied in two parts: (1) Demand modelled as a discrete random variable (2) Demand modelled as a continuous random variable. In the first part, we proposed an algorithm, the discrete stochastic strategy (DSS) algorithm that generates a strategic set of offers from the perspective of the Gencos' profits. The DSS offers were tested and compared to the deterministic Nash equilibrium (NE) offers based on the predicted demand. This comparison, based on the expected Genco profits, showed the DSS to be a better strategy in a probabilistic sense than the deterministic NE. In the second part, we presented three gaming strategies: (1) Deterministic NE (2) No-Risk (3) Risk-Taking. The strategies were then tested and their profit performances were compared using two assessment tools: (a) Expected value and standard deviation (b) Inverse cumulative distribution. We concluded that despite yielding higher profit performance under the right conjectures, Risk-Taking strategies are very sensitive to incorrect conjectures on the competitors' gaming decisions. As such, despite its lower profit performance, the No-Risk strategy was deemed preferable.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-27
...EPA is proposing to approve into the Illinois State Implementation Plan (SIP) an adjusted standard for Royal Fiberglass Pools (``Royal'') at its Dix, Illinois facility. On November 8, 2010, the Illinois Environmental Protection Agency (IEPA) submitted to EPA for approval an adjustment to the general rule, Use of Organic Material Rule, commonly known as the eight pound per hour (8 lb/hr) rule, as it applies to emissions of volatile organic matter (VOM) from Royal's pool manufacturing facility. The adjusted standard relieves Royal from being subject to the general rule for VOM emissions from its Dix facility. EPA is approving this SIP revision because it will not interfere with attainment or maintenance of the ozone National Ambient Air Quality Standard (NAAQS).
Remote auditing of radiotherapy facilities using optically stimulated luminescence dosimeters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lye, Jessica, E-mail: jessica.lye@arpansa.gov.au; Dunn, Leon; Kenny, John
Purpose: On 1 July 2012, the Australian Clinical Dosimetry Service (ACDS) released its Optically Stimulated Luminescent Dosimeter (OSLD) Level I audit, replacing the previous TLD based audit. The aim of this work is to present the results from this new service and the complete uncertainty analysis on which the audit tolerances are based. Methods: The audit release was preceded by a rigorous evaluation of the InLight® nanoDot OSLD system from Landauer (Landauer, Inc., Glenwood, IL). Energy dependence, signal fading from multiple irradiations, batch variation, reader variation, and dose response factors were identified and quantified for each individual OSLD. The detectorsmore » are mailed to the facility in small PMMA blocks, based on the design of the existing Radiological Physics Centre audit. Modeling and measurement were used to determine a factor that could convert the dose measured in the PMMA block, to dose in water for the facility's reference conditions. This factor is dependent on the beam spectrum. The TPR{sub 20,10} was used as the beam quality index to determine the specific block factor for a beam being audited. The audit tolerance was defined using a rigorous uncertainty calculation. The audit outcome is then determined using a scientifically based two tiered action level approach. Audit outcomes within two standard deviations were defined as Pass (Optimal Level), within three standard deviations as Pass (Action Level), and outside of three standard deviations the outcome is Fail (Out of Tolerance). Results: To-date the ACDS has audited 108 photon beams with TLD and 162 photon beams with OSLD. The TLD audit results had an average deviation from ACDS of 0.0% and a standard deviation of 1.8%. The OSLD audit results had an average deviation of −0.2% and a standard deviation of 1.4%. The relative combined standard uncertainty was calculated to be 1.3% (1σ). Pass (Optimal Level) was reduced to ≤2.6% (2σ), and Fail (Out of Tolerance) was reduced to >3.9% (3σ) for the new OSLD audit. Previously with the TLD audit the Pass (Optimal Level) and Fail (Out of Tolerance) were set at ≤4.0% (2σ) and >6.0% (3σ). Conclusions: The calculated standard uncertainty of 1.3% at one standard deviation is consistent with the measured standard deviation of 1.4% from the audits and confirming the suitability of the uncertainty budget derived audit tolerances. The OSLD audit shows greater accuracy than the previous TLD audit, justifying the reduction in audit tolerances. In the TLD audit, all outcomes were Pass (Optimal Level) suggesting that the tolerances were too conservative. In the OSLD audit 94% of the audits have resulted in Pass (Optimal level) and 6% of the audits have resulted in Pass (Action Level). All Pass (Action level) results have been resolved with a repeat OSLD audit, or an on-site ion chamber measurement.« less
Georgiadou, Elisavet; Stenström, Kristina Eriksson; Uvo, Cintia Bertacchi; Nilsson, Peter; Skog, Göran; Mattsson, Sören
2013-05-01
The (14)C content of 60 human blood serum samples from residents of Malmö (Sweden) in 1978, obtained from a biobank, has been measured to estimate the accuracy of (14)C bomb-pulse dating. The difference between the date estimated using the Calibomb software and sampling date varied between -3 ± 0.4 and +0.2 ± 0.5 years. The average age deviation of all samples was -1.5 ± 0.7 years, with the delay between production and consumption of foodstuffs being probably the dominating cause. The potential influence of food habits on the (14)C date has been evaluated using stable isotope δ(13)C and δ(15)N analysis and information about the dietary habits of the investigated individuals. Although the group consisting of lacto-ovo vegetarians and vegans (pooled group) was not completely separated from the omnivores in a stable isotopic trophic level diagram, this analysis proved to add valuable information on probable dietary habits. The age deviation of the sampling date from the respective Calibomb date was found strongly correlated with the δ(13)C values, probably due to influence from marine diet components. For the omnivore individuals, there were indications of seasonal effects on δ(13)C and the age deviation. No significant correlation was found between the age deviation and the δ(15)N values of any dietary group. No influence of sex or year of birth was found on neither the (14)C nor the δ(13)C and δ(15)N values of the serum samples. The data were also divided into two groups (omnivores and pooled group), based on the level of δ(15)N in the samples. The consumption of high δ(15)N-valued fish and birds can be responsible for this clustering.
Collinearity in Least-Squares Analysis
ERIC Educational Resources Information Center
de Levie, Robert
2012-01-01
How useful are the standard deviations per se, and how reliable are results derived from several least-squares coefficients and their associated standard deviations? When the output parameters obtained from a least-squares analysis are mutually independent, as is often assumed, they are reliable estimators of imprecision and so are the functions…
Robust Confidence Interval for a Ratio of Standard Deviations
ERIC Educational Resources Information Center
Bonett, Douglas G.
2006-01-01
Comparing variability of test scores across alternate forms, test conditions, or subpopulations is a fundamental problem in psychometrics. A confidence interval for a ratio of standard deviations is proposed that performs as well as the classic method with normal distributions and performs dramatically better with nonnormal distributions. A simple…
Standard Deviation for Small Samples
ERIC Educational Resources Information Center
Joarder, Anwar H.; Latif, Raja M.
2006-01-01
Neater representations for variance are given for small sample sizes, especially for 3 and 4. With these representations, variance can be calculated without a calculator if sample sizes are small and observations are integers, and an upper bound for the standard deviation is immediate. Accessible proofs of lower and upper bounds are presented for…
Estimating maize water stress by standard deviation of canopy temperature in thermal imagery
USDA-ARS?s Scientific Manuscript database
A new crop water stress index using standard deviation of canopy temperature as an input was developed to monitor crop water status. In this study, thermal imagery was taken from maize under various levels of deficit irrigation treatments in different crop growing stages. The Expectation-Maximizatio...
Marangoni Convection and Deviations from Maxwells' Evaporation Model
NASA Technical Reports Server (NTRS)
Segre, P. N.; Snell, E. H.; Adamek, D. H.
2003-01-01
We investigate the convective dynamics of evaporating pools of volatile liquids using an ultra-sensitive thermal imaging camera. During evaporation, there are significant convective flows inside the liquid due to Marangoni forces. We find that Marangoni convection during evaporation can dramatically affect the evaporation rates of volatile liquids. A simple heat balance model connects the convective velocities and temperature gradients to the evaporation rates.
Sub-Scale Analysis of New Large Aircraft Pool Fire-Suppression
2016-01-01
discrete ordinates radiation and single step Khan and Greeves soot model provided radiation and soot interaction. Agent spray dynamics were...Notable differences observed showed a modeled increase in the mockup surface heat-up rate as well as a modeled decreased rate of soot production...488 K SUPPRESSION STARTED Large deviation between sensors due to sensor alignment challenges and asymmetric fuel surface ignition Unremarkable
Experiments with central-limit properties of spatial samples from locally covariant random fields
Barringer, T.H.; Smith, T.E.
1992-01-01
When spatial samples are statistically dependent, the classical estimator of sample-mean standard deviation is well known to be inconsistent. For locally dependent samples, however, consistent estimators of sample-mean standard deviation can be constructed. The present paper investigates the sampling properties of one such estimator, designated as the tau estimator of sample-mean standard deviation. In particular, the asymptotic normality properties of standardized sample means based on tau estimators are studied in terms of computer experiments with simulated sample-mean distributions. The effects of both sample size and dependency levels among samples are examined for various value of tau (denoting the size of the spatial kernel for the estimator). The results suggest that even for small degrees of spatial dependency, the tau estimator exhibits significantly stronger normality properties than does the classical estimator of standardized sample means. ?? 1992.
Centrifugal Pumps for Swimming Pools. National Sanitation Foundation Standard Number 17.
ERIC Educational Resources Information Center
National Sanitation Foundation, Ann Arbor, MI. Committee for Swimming Pool Equipment Standards.
The pumps discussed herein are intended to be used for recirculating water in swimming pools, both public and private. Included are the basic components which may be a part of a pump such as the housing, strainer, impeller, valves, and such other parts as are attached or a part of the pump as supplied by the manufacturer. This standard is intended…
Sono-Koree, N K; Crist, R A; Frank, E L; Rodgers, G M; Smock, K J
2016-02-01
The serotonin release assay (SRA) is considered the gold standard laboratory test for heparin-induced thrombocytopenia (HIT). The historic SRA method uses platelets loaded with radiolabeled serotonin to evaluate platelet activation by HIT immune complexes. However, a nonradioactive method is desirable. We report the performance characteristics of a high-performance liquid chromatography (HPLC) SRA method. We validated the performance characteristics of an HPLC-SRA method, including correlation with a reference laboratory using the radioactive method. Serotonin released from reagent platelets was quantified by HPLC using fluorescent detection. Results were expressed as % release and classified as positive, negative, or indeterminate based on previously published cutoffs. Serum samples from 250 subjects with suspected HIT were tested in the HPLC-SRA and with the radioactive method. Concordant classifications were observed in 230 samples (92%). Sera from 41 healthy individuals tested negative. Between-run imprecision studies showed standard deviation of <6 (% release) for positive, weak positive, and negative serum pools. Stability studies demonstrated stability after two freeze-thaw cycles or up to a week of refrigeration. The HPLC-SRA has robust performance characteristics, equivalent to the historic radioactive method, but avoids the complexities of working with radioactivity. © 2015 John Wiley & Sons Ltd.
The regionalization of national-scale SPARROW models for stream nutrients
Schwarz, Gregory E.; Alexander, Richard B.; Smith, Richard A.; Preston, Stephen D.
2011-01-01
This analysis modifies the parsimonious specification of recently published total nitrogen (TN) and total phosphorus (TP) national-scale SPAtially Referenced Regressions On Watershed attributes models to allow each model coefficient to vary geographically among three major river basins of the conterminous United States. Regionalization of the national models reduces the standard errors in the prediction of TN and TP loads, expressed as a percentage of the predicted load, by about 6 and 7%. We develop and apply a method for combining national-scale and regional-scale information to estimate a hybrid model that imposes cross-region constraints that limit regional variation in model coefficients, effectively reducing the number of free model parameters as compared to a collection of independent regional models. The hybrid TN and TP regional models have improved model fit relative to the respective national models, reducing the standard error in the prediction of loads, expressed as a percentage of load, by about 5 and 4%. Only 19% of the TN hybrid model coefficients and just 2% of the TP hybrid model coefficients show evidence of substantial regional specificity (more than ±100% deviation from the national model estimate). The hybrid models have much greater precision in the estimated coefficients than do the unconstrained regional models, demonstrating the efficacy of pooling information across regions to improve regional models.
YALE NATURAL RADIOCARBON MEASUREMENTS. PART VI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stuiver, M.; Deevey, E.S.
1961-01-01
Most of the measurements made since publication of Yale V are included; some measurements, such as a series collected in Greenland, are withneld pending additional information or field work that will make better interpretations possible. In addition to radiocarbon dates of geologic and/or archaeologic interest, recent assays are given of C/sup 14/ in lake waters and other lacustrine materials, now normalized for C/sup 13/ content. The newly accepted convention is followed in expressing normalized C/sup 14/ values as DELTA = delta C/sup 14/ (2 delta C/sup 13/ + 50)STAl + ( delta C/sup 14//1000)! where DELTA is the per milmore » deviation of the C/sup 14/ if the sample from any contemporary standard (whether organic or a carbonate) after correction of sample and/or standard for real age, for the Suess effect, for normal isotopic fractionation, and for deviations of C/sup 14/ content of the age- and pollution- corrected l9th-century wood standard from that of 95% of the NBS oxalic acid standard; delta C/sup 14/ is the measured deviation from 95% of the NBS standard, and delta C/sup 13/ is the deviation from the NBS limestone standard, both in per mil. These assays are variously affected by artificial C/sup 14/ resulting from nuclear tests. (auth)« less
Yanagihara, Nobuyuki; Seki, Meikan; Nakano, Masahiro; Hachisuga, Toru; Goto, Yukio
2014-06-01
Disturbance of autonomic nervous activity has been thought to play a role in the climacteric symptoms of postmenopausal women. This study was therefore designed to investigate the relationship between autonomic nervous activity and climacteric symptoms in postmenopausal Japanese women. The autonomic nervous activity of 40 Japanese women with climacteric symptoms and 40 Japanese women without climacteric symptoms was measured by power spectral analysis of heart rate variability using a standard hexagonal radar chart. The scores for climacteric symptoms were determined using the simplified menopausal index. Sympathetic excitability and irritability, as well as the standard deviation of mean R-R intervals in supine position, were significantly (P < 0.01, 0.05, and 0.001, respectively) decreased in women with climacteric symptoms. There was a negative correlation between the standard deviation of mean R-R intervals in supine position and the simplified menopausal index score. The lack of control for potential confounding variables was a limitation of this study. In climacteric women, the standard deviation of mean R-R intervals in supine position is negatively correlated with the simplified menopausal index score.
45 CFR 148.310 - Eligibility requirements for a grant.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Qualified High Risk Pools § 148.310 Eligibility requirements for a grant. A State must meet all of the following requirements to be eligible for a grant: (a) The State has a qualified high risk pool as defined... the premium for applicable standard risk rates for the State. (c) The pool offers a choice of two or...
Code of Federal Regulations, 2010 CFR
2010-07-01
... average and corporate pool average sulfur level determined? 80.205 Section 80.205 Protection of... ADDITIVES Gasoline Sulfur Gasoline Sulfur Standards § 80.205 How is the annual refinery or importer average and corporate pool average sulfur level determined? (a) The annual refinery or importer average and...
Code of Federal Regulations, 2011 CFR
2011-07-01
... average and corporate pool average sulfur level determined? 80.205 Section 80.205 Protection of... ADDITIVES Gasoline Sulfur Gasoline Sulfur Standards § 80.205 How is the annual refinery or importer average and corporate pool average sulfur level determined? (a) The annual refinery or importer average and...
Code of Federal Regulations, 2013 CFR
2013-07-01
... average and corporate pool average sulfur level determined? 80.205 Section 80.205 Protection of... ADDITIVES Gasoline Sulfur Gasoline Sulfur Standards § 80.205 How is the annual refinery or importer average and corporate pool average sulfur level determined? (a) The annual refinery or importer average and...
Code of Federal Regulations, 2014 CFR
2014-07-01
... average and corporate pool average sulfur level determined? 80.205 Section 80.205 Protection of... ADDITIVES Gasoline Sulfur Gasoline Sulfur Standards § 80.205 How is the annual refinery or importer average and corporate pool average sulfur level determined? (a) The annual refinery or importer average and...
Addressing data privacy in matched studies via virtual pooling.
Saha-Chaudhuri, P; Weinberg, C R
2017-09-07
Data confidentiality and shared use of research data are two desirable but sometimes conflicting goals in research with multi-center studies and distributed data. While ideal for straightforward analysis, confidentiality restrictions forbid creation of a single dataset that includes covariate information of all participants. Current approaches such as aggregate data sharing, distributed regression, meta-analysis and score-based methods can have important limitations. We propose a novel application of an existing epidemiologic tool, specimen pooling, to enable confidentiality-preserving analysis of data arising from a matched case-control, multi-center design. Instead of pooling specimens prior to assay, we apply the methodology to virtually pool (aggregate) covariates within nodes. Such virtual pooling retains most of the information used in an analysis with individual data and since individual participant data is not shared externally, within-node virtual pooling preserves data confidentiality. We show that aggregated covariate levels can be used in a conditional logistic regression model to estimate individual-level odds ratios of interest. The parameter estimates from the standard conditional logistic regression are compared to the estimates based on a conditional logistic regression model with aggregated data. The parameter estimates are shown to be similar to those without pooling and to have comparable standard errors and confidence interval coverage. Virtual data pooling can be used to maintain confidentiality of data from multi-center study and can be particularly useful in research with large-scale distributed data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sleiman, Mohamad; Chen, Sharon; Gilbert, Haley E.
A laboratory method to simulate natural exposure of roofing materials has been reported in a companion article. Here in the current article, we describe the results of an international, nine-participant interlaboratory study (ILS) conducted in accordance with ASTM Standard E691-09 to establish the precision and reproducibility of this protocol. The accelerated soiling and weathering method was applied four times by each laboratory to replicate coupons of 12 products representing a wide variety of roofing categories (single-ply membrane, factory-applied coating (on metal), bare metal, field-applied coating, asphalt shingle, modified-bitumen cap sheet, clay tile, and concrete tile). Participants reported initial and laboratory-agedmore » values of solar reflectance and thermal emittance. Measured solar reflectances were consistent within and across eight of the nine participating laboratories. Measured thermal emittances reported by six participants exhibited comparable consistency. For solar reflectance, the accelerated aging method is both repeatable and reproducible within an acceptable range of standard deviations: the repeatability standard deviation sr ranged from 0.008 to 0.015 (relative standard deviation of 1.2–2.1%) and the reproducibility standard deviation sR ranged from 0.022 to 0.036 (relative standard deviation of 3.2–5.8%). The ILS confirmed that the accelerated aging method can be reproduced by multiple independent laboratories with acceptable precision. In conclusion, this study supports the adoption of the accelerated aging practice to speed the evaluation and performance rating of new cool roofing materials.« less
16 CFR 1207.2 - Effective date.
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARD FOR SWIMMING POOL SLIDES § 1207.2 Effective date. This part 1207 shall become effective July 17, 1976. All swimming pool slides manufactured after that date must meet the requirements of this part...
NASA Technical Reports Server (NTRS)
Herrman, B. D.; Uman, M. A.; Brantley, R. D.; Krider, E. P.
1976-01-01
The principle of operation of a wideband crossed-loop magnetic-field direction finder is studied by comparing the bearing determined from the NS and EW magnetic fields at various times up to 155 microsec after return stroke initiation with the TV-determined lightning channel base direction. For 40 lightning strokes in the 3 to 12 km range, the difference between the bearings found from magnetic fields sampled at times between 1 and 10 microsec and the TV channel-base data has a standard deviation of 3-4 deg. Included in this standard deviation is a 2-3 deg measurement error. For fields sampled at progressively later times, both the mean and the standard deviation of the difference between the direction-finder bearing and the TV bearing increase. Near 150 microsec, means are about 35 deg and standard deviations about 60 deg. The physical reasons for the late-time inaccuracies in the wideband direction finder and the occurrence of these effects in narrow-band VLF direction finders are considered.
Wavelength selection method with standard deviation: application to pulse oximetry.
Vazquez-Jaccaud, Camille; Paez, Gonzalo; Strojnik, Marija
2011-07-01
Near-infrared spectroscopy provides useful biological information after the radiation has penetrated through the tissue, within the therapeutic window. One of the significant shortcomings of the current applications of spectroscopic techniques to a live subject is that the subject may be uncooperative and the sample undergoes significant temporal variations, due to his health status that, from radiometric point of view, introduce measurement noise. We describe a novel wavelength selection method for monitoring, based on a standard deviation map, that allows low-noise sensitivity. It may be used with spectral transillumination, transmission, or reflection signals, including those corrupted by noise and unavoidable temporal effects. We apply it to the selection of two wavelengths for the case of pulse oximetry. Using spectroscopic data, we generate a map of standard deviation that we propose as a figure-of-merit in the presence of the noise introduced by the living subject. Even in the presence of diverse sources of noise, we identify four wavelength domains with standard deviation, minimally sensitive to temporal noise, and two wavelengths domains with low sensitivity to temporal noise.
How random is a random vector?
NASA Astrophysics Data System (ADS)
Eliazar, Iddo
2015-12-01
Over 80 years ago Samuel Wilks proposed that the "generalized variance" of a random vector is the determinant of its covariance matrix. To date, the notion and use of the generalized variance is confined only to very specific niches in statistics. In this paper we establish that the "Wilks standard deviation" -the square root of the generalized variance-is indeed the standard deviation of a random vector. We further establish that the "uncorrelation index" -a derivative of the Wilks standard deviation-is a measure of the overall correlation between the components of a random vector. Both the Wilks standard deviation and the uncorrelation index are, respectively, special cases of two general notions that we introduce: "randomness measures" and "independence indices" of random vectors. In turn, these general notions give rise to "randomness diagrams"-tangible planar visualizations that answer the question: How random is a random vector? The notion of "independence indices" yields a novel measure of correlation for Lévy laws. In general, the concepts and results presented in this paper are applicable to any field of science and engineering with random-vectors empirical data.
Estimation of Tooth Size Discrepancies among Different Malocclusion Groups.
Hasija, Narender; Bala, Madhu; Goyal, Virender
2014-05-01
Regards and Tribute: Late Dr Narender Hasija was a mentor and visionary in the light of knowledge and experience. We pay our regards with deepest gratitude to the departed soul to rest in peace. Bolton's ratios help in estimating overbite, overjet relationships, the effects of contemplated extractions on posterior occlusion, incisor relationships and identification of occlusal misfit produced by tooth size discrepancies. To determine any difference in tooth size discrepancy in anterior as well as overall ratio in different malocclusions and comparison with Bolton's study. After measuring the teeth on all 100 patients, Bolton's analysis was performed. Results were compared with Bolton's means and standard deviations. The results were also subjected to statistical analysis. Results show that the mean and standard deviations of ideal occlusion cases are comparable with those Bolton but, when the mean and standard deviation of malocclusion groups are compared with those of Bolton, the values of standard deviation are higher, though the mean is comparable. How to cite this article: Hasija N, Bala M, Goyal V. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups. Int J Clin Pediatr Dent 2014;7(2):82-85.
Association of auricular pressing and heart rate variability in pre-exam anxiety students.
Wu, Wocao; Chen, Junqi; Zhen, Erchuan; Huang, Huanlin; Zhang, Pei; Wang, Jiao; Ou, Yingyi; Huang, Yong
2013-03-25
A total of 30 students scoring between 12 and 20 on the Test Anxiety Scale who had been exhibiting an anxious state > 24 hours, and 30 normal control students were recruited. Indices of heart rate variability were recorded using an Actiheart electrocardiogram recorder at 10 minutes before auricular pressing, in the first half of stimulation and in the second half of stimulation. The results revealed that the standard deviation of all normal to normal intervals and the root mean square of standard deviation of normal to normal intervals were significantly increased after stimulation. The heart rate variability triangular index, very-low-frequency power, low-frequency power, and the ratio of low-frequency to high-frequency power were increased to different degrees after stimulation. Compared with normal controls, the root mean square of standard deviation of normal to normal intervals was significantly increased in anxious students following auricular pressing. These results indicated that auricular pressing can elevate heart rate variability, especially the root mean square of standard deviation of normal to normal intervals in students with pre-exam anxiety.
Association of auricular pressing and heart rate variability in pre-exam anxiety students
Wu, Wocao; Chen, Junqi; Zhen, Erchuan; Huang, Huanlin; Zhang, Pei; Wang, Jiao; Ou, Yingyi; Huang, Yong
2013-01-01
A total of 30 students scoring between 12 and 20 on the Test Anxiety Scale who had been exhibiting an anxious state > 24 hours, and 30 normal control students were recruited. Indices of heart rate variability were recorded using an Actiheart electrocardiogram recorder at 10 minutes before auricular pressing, in the first half of stimulation and in the second half of stimulation. The results revealed that the standard deviation of all normal to normal intervals and the root mean square of standard deviation of normal to normal intervals were significantly increased after stimulation. The heart rate variability triangular index, very-low-frequency power, low-frequency power, and the ratio of low-frequency to high-frequency power were increased to different degrees after stimulation. Compared with normal controls, the root mean square of standard deviation of normal to normal intervals was significantly increased in anxious students following auricular pressing. These results indicated that auricular pressing can elevate heart rate variability, especially the root mean square of standard deviation of normal to normal intervals in students with pre-exam anxiety. PMID:25206734
Offshore fatigue design turbulence
NASA Astrophysics Data System (ADS)
Larsen, Gunner C.
2001-07-01
Fatigue damage on wind turbines is mainly caused by stochastic loading originating from turbulence. While onshore sites display large differences in terrain topology, and thereby also in turbulence conditions, offshore sites are far more homogeneous, as the majority of them are likely to be associated with shallow water areas. However, despite this fact, specific recommendations on offshore turbulence intensities, applicable for fatigue design purposes, are lacking in the present IEC code. This article presents specific guidelines for such loading. These guidelines are based on the statistical analysis of a large number of wind data originating from two Danish shallow water offshore sites. The turbulence standard deviation depends on the mean wind speed, upstream conditions, measuring height and thermal convection. Defining a population of turbulence standard deviations, at a given measuring position, uniquely by the mean wind speed, variations in upstream conditions and atmospheric stability will appear as variability of the turbulence standard deviation. Distributions of such turbulence standard deviations, conditioned on the mean wind speed, are quantified by fitting the measured data to logarithmic Gaussian distributions. By combining a simple heuristic load model with the parametrized conditional probability density functions of the turbulence standard deviations, an empirical offshore design turbulence intensity is determined. For pure stochastic loading (as associated with standstill situations), the design turbulence intensity yields a fatigue damage equal to the average fatigue damage caused by the distributed turbulence intensity. If the stochastic loading is combined with a periodic deterministic loading (as in the normal operating situation), the proposed design turbulence intensity is shown to be conservative.
Estimating extreme stream temperatures by the standard deviate method
NASA Astrophysics Data System (ADS)
Bogan, Travis; Othmer, Jonathan; Mohseni, Omid; Stefan, Heinz
2006-02-01
It is now widely accepted that global climate warming is taking place on the earth. Among many other effects, a rise in air temperatures is expected to increase stream temperatures indefinitely. However, due to evaporative cooling, stream temperatures do not increase linearly with increasing air temperatures indefinitely. Within the anticipated bounds of climate warming, extreme stream temperatures may therefore not rise substantially. With this concept in mind, past extreme temperatures measured at 720 USGS stream gauging stations were analyzed by the standard deviate method. In this method the highest stream temperatures are expressed as the mean temperature of a measured partial maximum stream temperature series plus its standard deviation multiplied by a factor KE (standard deviate). Various KE-values were explored; values of KE larger than 8 were found physically unreasonable. It is concluded that the value of KE should be in the range from 7 to 8. A unit error in estimating KE translates into a typical stream temperature error of about 0.5 °C. Using a logistic model for the stream temperature/air temperature relationship, a one degree error in air temperature gives a typical error of 0.16 °C in stream temperature. With a projected error in the enveloping standard deviate dKE=1.0 (range 0.5-1.5) and an error in projected high air temperature d Ta=2 °C (range 0-4 °C), the total projected stream temperature error is estimated as d Ts=0.8 °C.
NASA Technical Reports Server (NTRS)
Rhoads, James E.; Rigby, Jane Rebecca; Malhotra, Sangeeta; Allam, Sahar; Carilli, Chris; Combes, Francoise; Finkelstein, Keely; Finkelstein, Steven; Frye, Brenda; Gerin, Maryvonne;
2014-01-01
We report on two regularly rotating galaxies at redshift z approx. = 2, using high-resolution spectra of the bright [C microns] 158 micrometers emission line from the HIFI instrument on the Herschel Space Observatory. Both SDSS090122.37+181432.3 ("S0901") and SDSSJ120602.09+514229.5 ("the Clone") are strongly lensed and show the double-horned line profile that is typical of rotating gas disks. Using a parametric disk model to fit the emission line profiles, we find that S0901 has a rotation speed of v sin(i) approx. = 120 +/- 7 kms(sup -1) and a gas velocity dispersion of (standard deviation)g < 23 km s(sup -1) (1(standard deviation)). The best-fitting model for the Clone is a rotationally supported disk having v sin(i) approx. = 79 +/- 11 km s(sup -1) and (standard deviation)g 4 kms(sup -1) (1(standard deviation)). However, the Clone is also consistent with a family of dispersion-dominated models having (standard deviation)g = 92 +/- 20 km s(sup -1). Our results showcase the potential of the [C microns] line as a kinematic probe of high-redshift galaxy dynamics: [C microns] is bright, accessible to heterodyne receivers with exquisite velocity resolution, and traces dense star-forming interstellar gas. Future [C microns] line observations with ALMA would offer the further advantage of spatial resolution, allowing a clearer separation between rotation and velocity dispersion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fried, D; Meier, J; Mawlawi, O
Purpose: Use a NEMA-IEC PET phantom to assess the robustness of FDG-PET-based radiomics features to changes in reconstruction parameters across different scanners. Methods: We scanned a NEMA-IEC PET phantom on 3 different scanners (GE Discovery VCT, GE Discovery 710, and Siemens mCT) using a FDG source-to-background ratio of 10:1. Images were retrospectively reconstructed using different iterations (2–3), subsets (21–24), Gaussian filter widths (2, 4, 6mm), and matrix sizes (128,192,256). The 710 and mCT used time-of-flight and point-spread-functions in reconstruction. The axial-image through the center of the 6 active spheres was used for analysis. A region-of-interest containing all spheres was ablemore » to simulate a heterogeneous lesion due to partial volume effects. Maximum voxel deviations from all retrospectively reconstructed images (18 per scanner) was compared to our standard clinical protocol. PET Images from 195 non-small cell lung cancer patients were used to compare feature variation. The ratio of a feature’s standard deviation from the patient cohort versus the phantom images was calculated to assess for feature robustness. Results: Across all images, the percentage of voxels differing by <1SUV and <2SUV ranged from 61–92% and 88–99%, respectively. Voxel-voxel similarity decreased when using higher resolution image matrices (192/256 versus 128) and was comparable across scanners. Taking the ratio of patient and phantom feature standard deviation was able to identify features that were not robust to changes in reconstruction parameters (e.g. co-occurrence correlation). Metrics found to be reasonably robust (standard deviation ratios > 3) were observed for routinely used SUV metrics (e.g. SUVmean and SUVmax) as well as some radiomics features (e.g. co-occurrence contrast, co-occurrence energy, standard deviation, and uniformity). Similar standard deviation ratios were observed across scanners. Conclusions: Our method enabled a comparison of feature variability across scanners and was able to identify features that were not robust to changes in reconstruction parameters.« less
NASA Astrophysics Data System (ADS)
Stier, P.; Schutgens, N. A. J.; Bian, H.; Boucher, O.; Chin, M.; Ghan, S.; Huneeus, N.; Kinne, S.; Lin, G.; Myhre, G.; Penner, J. E.; Randles, C.; Samset, B.; Schulz, M.; Yu, H.; Zhou, C.
2012-09-01
Simulated multi-model "diversity" in aerosol direct radiative forcing estimates is often perceived as measure of aerosol uncertainty. However, current models used for aerosol radiative forcing calculations vary considerably in model components relevant for forcing calculations and the associated "host-model uncertainties" are generally convoluted with the actual aerosol uncertainty. In this AeroCom Prescribed intercomparison study we systematically isolate and quantify host model uncertainties on aerosol forcing experiments through prescription of identical aerosol radiative properties in nine participating models. Even with prescribed aerosol radiative properties, simulated clear-sky and all-sky aerosol radiative forcings show significant diversity. For a purely scattering case with globally constant optical depth of 0.2, the global-mean all-sky top-of-atmosphere radiative forcing is -4.51 W m-2 and the inter-model standard deviation is 0.70 W m-2, corresponding to a relative standard deviation of 15%. For a case with partially absorbing aerosol with an aerosol optical depth of 0.2 and single scattering albedo of 0.8, the forcing changes to 1.26 W m-2, and the standard deviation increases to 1.21 W m-2, corresponding to a significant relative standard deviation of 96%. However, the top-of-atmosphere forcing variability owing to absorption is low, with relative standard deviations of 9% clear-sky and 12% all-sky. Scaling the forcing standard deviation for a purely scattering case to match the sulfate radiative forcing in the AeroCom Direct Effect experiment, demonstrates that host model uncertainties could explain about half of the overall sulfate forcing diversity of 0.13 W m-2 in the AeroCom Direct Radiative Effect experiment. Host model errors in aerosol radiative forcing are largest in regions of uncertain host model components, such as stratocumulus cloud decks or areas with poorly constrained surface albedos, such as sea ice. Our results demonstrate that host model uncertainties are an important component of aerosol forcing uncertainty that require further attention.
Robust Alternatives to the Standard Deviation in Processing of Physics Experimental Data
NASA Astrophysics Data System (ADS)
Shulenin, V. P.
2016-10-01
Properties of robust estimations of the scale parameter are studied. It is noted that the median of absolute deviations and the modified estimation of the average Gini differences have asymptotically normal distributions and bounded influence functions, are B-robust estimations, and hence, unlike the estimation of the standard deviation, are protected from the presence of outliers in the sample. Results of comparison of estimations of the scale parameter are given for a Gaussian model with contamination. An adaptive variant of the modified estimation of the average Gini differences is considered.
Temporal and spatial variability in thalweg profiles of a gravel-bed river
Madej, Mary Ann
1999-01-01
This study used successive longitudinal thalweg profiles in gravel-bed rivers to monitor changes in bed topography following floods and associated large sediment inputs. Variations in channel bed elevations, distributions of residual water depths, percentage of channel length occupied by riffles, and a spatial autocorrelation coefficient (Moran's I) were used to quantify changes in morphological diversity and spatial structure in Redwood Creek basin, northwestern California. Bed topography in Redwood Creek and its major tributaries consists primarily of a series of pools and riffles. The size, frequency and spatial distribution of the pools and riffles have changed significantly during the past 20 years. Following large floods and high sediment input in Redwood Creek and its tributaries in 1975, variation in channel bed elevations was low and the percentage of the channel length occupied by riffles was high. Over the next 20 years, variation in bed elevations increased while the length of channel occupied by riffles decreased. An index [(standard deviation of residual water depth/bankfull depth) × 100] was developed to compare variations in bed elevation over a range of stream sizes, with a higher index being indicative of greater morphological diversity. Spatial autocorrelation in the bed elevation data was apparent at both fine and coarse scales in many of the thalweg profiles and the observed spatial pattern of bed elevations was found to be related to the dominant channel material and the time since disturbance. River reaches in which forced pools dominated, and in which large woody debris and bed particles could not be easily mobilized, exhibited a random distribution of bed elevations. In contrast, in reaches where alternate bars dominated, and both wood and gravel were readily transported, regularly spaced bed topography developed at a spacing that increased with time since disturbance. This pattern of regularly spaced bed features was reversed following a 12-year flood when bed elevations became more randomly arranged.
Anatomical-based partial volume correction for low-dose dedicated cardiac SPECT/CT
NASA Astrophysics Data System (ADS)
Liu, Hui; Chan, Chung; Grobshtein, Yariv; Ma, Tianyu; Liu, Yaqiang; Wang, Shi; Stacy, Mitchel R.; Sinusas, Albert J.; Liu, Chi
2015-09-01
Due to the limited spatial resolution, partial volume effect has been a major degrading factor on quantitative accuracy in emission tomography systems. This study aims to investigate the performance of several anatomical-based partial volume correction (PVC) methods for a dedicated cardiac SPECT/CT system (GE Discovery NM/CT 570c) with focused field-of-view over a clinically relevant range of high and low count levels for two different radiotracer distributions. These PVC methods include perturbation geometry transfer matrix (pGTM), pGTM followed by multi-target correction (MTC), pGTM with known concentration in blood pool, the former followed by MTC and our newly proposed methods, which perform the MTC method iteratively, where the mean values in all regions are estimated and updated by the MTC-corrected images each time in the iterative process. The NCAT phantom was simulated for cardiovascular imaging with 99mTc-tetrofosmin, a myocardial perfusion agent, and 99mTc-red blood cell (RBC), a pure intravascular imaging agent. Images were acquired at six different count levels to investigate the performance of PVC methods in both high and low count levels for low-dose applications. We performed two large animal in vivo cardiac imaging experiments following injection of 99mTc-RBC for evaluation of intramyocardial blood volume (IMBV). The simulation results showed our proposed iterative methods provide superior performance than other existing PVC methods in terms of image quality, quantitative accuracy, and reproducibility (standard deviation), particularly for low-count data. The iterative approaches are robust for both 99mTc-tetrofosmin perfusion imaging and 99mTc-RBC imaging of IMBV and blood pool activity even at low count levels. The animal study results indicated the effectiveness of PVC to correct the overestimation of IMBV due to blood pool contamination. In conclusion, the iterative PVC methods can achieve more accurate quantification, particularly for low count cardiac SPECT studies, typically obtained from low-dose protocols, gated studies, and dynamic applications.
40 CFR 63.7751 - What reports must I submit and when?
Code of Federal Regulations, 2010 CFR
2010-07-01
... deviations from any emissions limitations (including operating limit), work practice standards, or operation and maintenance requirements, a statement that there were no deviations from the emissions limitations...-of-control during the reporting period. (7) For each deviation from an emissions limitation...
Ma, Jiantao; Karlsen, Micaela C.; Chung, Mei; Jacques, Paul F.; Saltzman, Edward; Smith, Caren E.; Fox, Caroline S.
2016-01-01
Context: The effect of added sugar intake on ectopic fat accumulation is a subject of debate. Objective: A systematic review and meta-analysis of randomized controlled trials (RCTs) was conducted to examine the potential effect of added sugar intake on ectopic fat depots. Data Sources: MEDLINE, CAB Abstracts, CAB Global Health, and EBM (Evidence-Based Medicine) Reviews – Cochrane Central Register of Controlled Trials databases were searched for studies published from 1973 to September 2014. Data Extraction: RCTs with a minimum of 6 days’ duration of added sugar exposure in the intervention group were selected. The dosage of added sugar intake as a percentage of total energy was extracted or calculated. Means and standard deviations of pre- and post-test measurements or changes in ectopic fat depots were collected. Data Synthesis: Fourteen RCTs were included. Most of the studies had a medium to high risk of bias. Meta-analysis showed that, compared with eucaloric controls, subjects who consumed added sugar under hypercaloric conditions likely increased ectopic fat, particularly in the liver (pooled standardized mean difference = 0.9 [95%CI, 0.6–1.2], n = 6) and muscles (pooled SMD = 0.6 [95%CI, 0.2–1.0], n = 4). No significant difference was observed in liver fat, visceral adipose tissue, or muscle fat when isocaloric intakes of different sources of added sugars were compared. Conclusions: Data from a limited number of RCTs suggest that excess added sugar intake under hypercaloric diet conditions likely increases ectopic fat depots, particularly in the liver and in muscle fat. There are insufficient data to compare the effect of different sources of added sugars on ectopic fat deposition or to compare intake of added sugar with intakes of other macronutrients. Future well-designed RCTs with sufficient power and duration are needed to address the role of sugars on ectopic fat deposition. PMID:26518034
Sergentanis, Theodoros N; Economopoulos, Konstantinos P
2011-11-01
Cyclin D1 represents a key molecule in the regulation of cell cycle. CCND1 G870A (rs603965) polymorphism has drawn considerable attention as the A allele may generate a variant splice product with possible oncogenic actions. A meta-analysis examining the association between CCND1 G870A polymorphism and breast cancer risk was performed. Separate analyses on Caucasian and Chinese populations were also implemented. Eligible articles were identified for the period up to July 2010. Pooled odds ratios (OR) were appropriately derived from fixed-effects or random-effects models. Sensitivity analysis excluding studies whose genotype frequencies in controls significantly deviated from Hardy-Weinberg Equilibrium (HWE) was performed. Nine case-control studies on Caucasians (7,304 cases and 8,149 controls) and four case-control studies on Chinese (2,607 cases and 3,022 controls) were eligible. At the overall analysis the A allele seemed to be associated with elevated breast cancer risk; the effect seemed to be confined to homozygous carriers (pooled OR = 1.091, 95% CI: 1.008-1.179, P = 0.030, fixed effects) as heterozygous carriers did not exhibit significantly elevated breast cancer risk. No statistically significant associations were demonstrated in Caucasians. On the other hand, Chinese AA carriers exhibited marginally elevated breast cancer risk (pooled OR = 1.144, 95% CI: 0.984-1.329, P = 0.080, fixed effects). Nevertheless, the controls in two out of the four Chinese studies deviated from HWE. In conclusion, this meta-analysis suggests that the A allele of the CCND1 G870A polymorphism may confer additional breast cancer risk when it comes to homozygosity and Chinese populations. The need for additional, methodologically sound studies on Chinese populations seems warranted.
Huang, Yuan-sheng; Yang, Zhi-rong; Zhan, Si-yan
2015-06-18
To investigate the use of simple pooling and bivariate model in meta-analyses of diagnostic test accuracy (DTA) published in Chinese journals (January to November, 2014), compare the differences of results from these two models, and explore the impact of between-study variability of sensitivity and specificity on the differences. DTA meta-analyses were searched through Chinese Biomedical Literature Database (January to November, 2014). Details in models and data for fourfold table were extracted. Descriptive analysis was conducted to investigate the prevalence of the use of simple pooling method and bivariate model in the included literature. Data were re-analyzed with the two models respectively. Differences in the results were examined by Wilcoxon signed rank test. How the results differences were affected by between-study variability of sensitivity and specificity, expressed by I2, was explored. The 55 systematic reviews, containing 58 DTA meta-analyses, were included and 25 DTA meta-analyses were eligible for re-analysis. Simple pooling was used in 50 (90.9%) systematic reviews and bivariate model in 1 (1.8%). The remaining 4 (7.3%) articles used other models pooling sensitivity and specificity or pooled neither of them. Of the reviews simply pooling sensitivity and specificity, 41(82.0%) were at the risk of wrongly using Meta-disc software. The differences in medians of sensitivity and specificity between two models were both 0.011 (P<0.001, P=0.031 respectively). Greater differences could be found as I2 of sensitivity or specificity became larger, especially when I2>75%. Most DTA meta-analyses published in Chinese journals(January to November, 2014) combine the sensitivity and specificity by simple pooling. Meta-disc software can pool the sensitivity and specificity only through fixed-effect model, but a high proportion of authors think it can implement random-effect model. Simple pooling tends to underestimate the results compared with bivariate model. The greater the between-study variance is, the more likely the simple pooling has larger deviation. It is necessary to increase the knowledge level of statistical methods and software for meta-analyses of DTA data.
Evaluation of the VERSANT HCV RNA 3.0 assay for quantification of hepatitis C virus RNA in serum.
Trimoulet, Pascale; Halfon, Philippe; Pohier, Eric; Khiri, Hacène; Chêne, Geneviève; Fleury, Hervé
2002-06-01
We assessed the performance of a new assay (VERSANT HCV RNA 3.0 [bDNA 3.0] assay [Bayer Diagnostics]) to quantitate HCV RNA levels and compared the results of the bDNA 3.0 assay to results of the Quantiplex HCV RNA 2.0 (bDNA 2.0) assay. Samples used in this study included 211 serum specimens from hepatitis C virus (HCV)-infected persons from two sites (Bordeaux and Marseille, France) with different genotypes; 383 serum specimens from HCV antibody-negative, HCV RNA-negative persons; and serial dilutions of World Health Organization (WHO) HCV RNA standard at a titer of 100,000 IU/ml. The specificity of the bDNA 3.0 assay was 98.2%. A high correlation was observed between expected and observed values in all dilutions of WHO standard (r = 0.9982), in serial dilutions of pooled samples (r = 0.9996), and in diluted sera from different HCV genotypes (r = 0.9930 to 0.9995). The standard deviations (SD) for the within-run and between-run reproducibility of the bDNA 3.0 assay were
Evaluation of the VERSANT HCV RNA 3.0 Assay for Quantification of Hepatitis C Virus RNA in Serum
Trimoulet, Pascale; Halfon, Philippe; Pohier, Eric; Khiri, Hacène; Chêne, Geneviève; Fleury, Hervé
2002-01-01
We assessed the performance of a new assay (VERSANT HCV RNA 3.0 [bDNA 3.0] assay [Bayer Diagnostics]) to quantitate HCV RNA levels and compared the results of the bDNA 3.0 assay to results of the Quantiplex HCV RNA 2.0 (bDNA 2.0) assay. Samples used in this study included 211 serum specimens from hepatitis C virus (HCV)-infected persons from two sites (Bordeaux and Marseille, France) with different genotypes; 383 serum specimens from HCV antibody-negative, HCV RNA-negative persons; and serial dilutions of World Health Organization (WHO) HCV RNA standard at a titer of 100,000 IU/ml. The specificity of the bDNA 3.0 assay was 98.2%. A high correlation was observed between expected and observed values in all dilutions of WHO standard (r = 0.9982), in serial dilutions of pooled samples (r = 0.9996), and in diluted sera from different HCV genotypes (r = 0.9930 to 0.9995). The standard deviations (SD) for the within-run and between-run reproducibility of the bDNA 3.0 assay were ≤0.2 and ≤0.14, respectively. The intersite SD ranged from 0.03 to 0.14. The bDNA 3.0 assay results were positively correlated with the bDNA 2.0 assay results (r = 0.9533). Taking in account the overall performance, this assay could be used as a routine tool for the HCV RNA quantification. PMID:12037059
Use of Standard Deviations as Predictors in Models Using Large-Scale International Data Sets
ERIC Educational Resources Information Center
Austin, Bruce; French, Brian; Adesope, Olusola; Gotch, Chad
2017-01-01
Measures of variability are successfully used in predictive modeling in research areas outside of education. This study examined how standard deviations can be used to address research questions not easily addressed using traditional measures such as group means based on index variables. Student survey data were obtained from the Organisation for…
Screen Twice, Cut Once: Assessing the Predictive Validity of Teacher Selection Tools
ERIC Educational Resources Information Center
Goldhaber, Dan; Grout, Cyrus; Huntington-Klein, Nick
2015-01-01
It is well documented that teachers can have profound effects on student outcomes. Empirical estimates find that a one standard deviation increase in teacher quality raises student test achievement by 10 to 25 percent of a standard deviation. More recent evidence shows that the effectiveness of teachers can affect long-term student outcomes, such…
Comparing Measurement Error between Two Different Methods of Measurement of Various Magnitudes
ERIC Educational Resources Information Center
Zavorsky, Gerald S.
2010-01-01
Measurement error is a common problem in several fields of research such as medicine, physiology, and exercise science. The standard deviation of repeated measurements on the same person is the measurement error. One way of presenting measurement error is called the repeatability, which is 2.77 multiplied by the within subject standard deviation.…
Parabolic trough receiver heat loss and optical efficiency round robin 2015/2016
NASA Astrophysics Data System (ADS)
Pernpeintner, Johannes; Schiricke, Björn; Sallaberry, Fabienne; de Jalón, Alberto García; López-Martín, Rafael; Valenzuela, Loreto; de Luca, Antonio; Georg, Andreas
2017-06-01
A round robin for parabolic trough receiver heat loss and optical efficiency in the laboratory was performed between five institutions using five receivers in 2015/2016. Heat loss testing was performed at three cartridge heater test benches and one Joule heating test bench in the temperature range between 100 °C and 550 °C. Optical efficiency testing was performed with two spectrometric test bench and one calorimetric test bench. Heat loss testing results showed standard deviations at the order of 6% to 12 % for most temperatures and receivers and a standard deviation of 17 % for one receiver at 100 °C. Optical efficiency is presented normalized for laboratories showing standard deviations of 0.3 % to 1.3 % depending on the receiver.
Benign positional vertigo and hyperuricaemia.
Adam, A M
2005-07-01
To find out if there is any association between serum uric acid level and positional vertigo. A prospective, case controlled study. A private neurological clinic. All patients presenting with vertigo. Ninety patients were seen in this period with 78 males and 19 females. Mean age was 47 +/- 3 years (at 95% confidence level) with a standard deviation of 12.4. Their mean uric acid level was 442 +/- 16 (at 95% confidence level) with a standard deviation of 79.6 umol/l as compared to 291 +/- 17 (at 95% confidence level) with a standard deviation of 79.7 umol/l in the control group. The P-value was less than 0.001. That there is a significant association between high uric acid and benign positional vertigo.
NASA Technical Reports Server (NTRS)
Clark, P. E.; Andre, C. G.; Adler, I.; Weidner, J.; Podwysocki, M.
1976-01-01
The positive correlation between Al/Si X-ray fluorescence intensity ratios determined during the Apollo 15 lunar mission and a broad-spectrum visible albedo of the moon is quantitatively established. Linear regression analysis performed on 246 1 degree geographic cells of X-ray fluorescence intensity and visible albedo data points produced a statistically significant correlation coefficient of .78. Three distinct distributions of data were identified as (1) within one standard deviation of the regression line, (2) greater than one standard deviation below the line, and (3) greater than one standard deviation above the line. The latter two distributions of data were found to occupy distinct geographic areas in the Palus Somni region.
Screening Samples for Arsenic by Inductively Coupled Plasma-Mass Spectrometry for Treaty Samples
2014-02-01
2.274 3.657 10.06 14.56 30.36 35.93 % RSD : 15.87% 4.375% 2.931% 4.473% 3.349% 3.788% 2.802% 3.883% 3.449% RSD , relative standard deviation 9 Table...107.9% 106.4% Standard Deviation: 0.3171 0.3498 0.8024 2.964 4.526 10.06 13.83 16.38 11.81 % RSD : 5.657% 3.174% 3.035% 5.507% 4.332% 3.795% 2.626...119.1% 116.5% 109.4% 106.8% 105.2% 105.5% 105.8% 108.6% 107.8% Standard Deviation: 0.2379 0.5595 1.173 2.375 2.798 5.973 11.79 15.10 30.54 % RSD
A deviation display method for visualising data in mobile gamma-ray spectrometry.
Kock, Peder; Finck, Robert R; Nilsson, Jonas M C; Ostlund, Karl; Samuelsson, Christer
2010-09-01
A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded (137)Cs and (241)Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialization time of about 10min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.
Castro-Sánchez, Adelaida María; Matarán-Peñarrocha, Guillermo A; Sánchez-Labraca, Nuria; Quesada-Rubio, José Manuel; Granero-Molina, José; Moreno-Lorenzo, Carmen
2011-01-01
Fibromyalgia is a prevalent musculoskeletal disorder associated with widespread mechanical tenderness, fatigue, non-refreshing sleep, depressed mood and pervasive dysfunction of the autonomic nervous system: tachycardia, postural intolerance, Raynaud's phenomenon and diarrhoea. To determine the effects of craniosacral therapy on sensitive tender points and heart rate variability in patients with fibromyalgia. A randomized controlled trial. Ninety-two patients with fibromyalgia were randomly assigned to an intervention group or placebo group. Patients received treatments for 20 weeks. The intervention group underwent a craniosacral therapy protocol and the placebo group received sham treatment with disconnected magnetotherapy equipment. Pain intensity levels were determined by evaluating tender points, and heart rate variability was recorded by 24-hour Holter monitoring. After 20 weeks of treatment, the intervention group showed significant reduction in pain at 13 of the 18 tender points (P < 0.05). Significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement versus baseline values were observed in the intervention group but not in the placebo group. At two months and one year post therapy, the intervention group showed significant differences versus baseline in tender points at left occiput, left-side lower cervical, left epicondyle and left greater trochanter and significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement. Craniosacral therapy improved medium-term pain symptoms in patients with fibromyalgia.
Code of Federal Regulations, 2010 CFR
2010-07-01
... which are distinct from the standard deviation process and specific to the requirements of the Federal... agency request a deviation from the provisions of this part? 102-38.30 Section 102-38.30 Public Contracts... executive agency request a deviation from the provisions of this part? Refer to §§ 102-2.60 through 102-2...
Family structure and childhood anthropometry in Saint Paul, Minnesota in 1918
Warren, John Robert
2017-01-01
Concern with childhood nutrition prompted numerous surveys of children’s growth in the United States after 1870. The Children’s Bureau’s 1918 “Weighing and Measuring Test” measured two million children to produce the first official American growth norms. Individual data for 14,000 children survives from the Saint Paul, Minnesota survey whose stature closely approximated national norms. As well as anthropometry the survey recorded exact ages, street address and full name. These variables allow linkage to the 1920 census to obtain demographic and socioeconomic information. We matched 72% of children to census families creating a sample of nearly 10,000 children. Children in the entire survey (linked set) averaged 0.74 (0.72) standard deviations below modern WHO height-for-age standards, and 0.48 (0.46) standard deviations below modern weight-for-age norms. Sibship size strongly influenced height-for-age, and had weaker influence on weight-for-age. Each additional child six or underreduced height-for-age scores by 0.07 standard deviations (95% CI: −0.03, 0.11). Teenage siblings had little effect on height-forage. Social class effects were substantial. Children of laborers averaged half a standard deviation shorter than children of professionals. Family structure and socio-economic status had compounding impacts on children’s stature. PMID:28943749
Schroder, L.J.; Brooks, M.H.; Malo, B.A.; Willoughby, T.C.
1986-01-01
Five intersite comparison studies for the field determination of pH and specific conductance, using simulated-precipitation samples, were conducted by the U.S.G.S. for the National Atmospheric Deposition Program and National Trends Network. These comparisons were performed to estimate the precision of pH and specific conductance determinations made by sampling-site operators. Simulated-precipitation samples were prepared from nitric acid and deionized water. The estimated standard deviation for site-operator determination of pH was 0.25 for pH values ranging from 3.79 to 4.64; the estimated standard deviation for specific conductance was 4.6 microsiemens/cm at 25 C for specific-conductance values ranging from 10.4 to 59.0 microsiemens/cm at 25 C. Performance-audit samples with known analyte concentrations were prepared by the U.S.G.S.and distributed to the National Atmospheric Deposition Program 's Central Analytical Laboratory. The differences between the National Atmospheric Deposition Program and national Trends Network-reported analyte concentrations and known analyte concentrations were calculated, and the bias and precision were determined. For 1983, concentrations of calcium, magnesium, sodium, and chloride were biased at the 99% confidence limit; concentrations of potassium and sulfate were unbiased at the 99% confidence limit. Four analytical laboratories routinely analyzing precipitation were evaluated in their analysis of identical natural- and simulated precipitation samples. Analyte bias for each laboratory was examined using analysis of variance coupled with Duncan 's multiple-range test on data produced by these laboratories, from the analysis of identical simulated-precipitation samples. Analyte precision for each laboratory has been estimated by calculating a pooled variance for each analyte. Interlaboratory comparability results may be used to normalize natural-precipitation chemistry data obtained from two or more of these laboratories. (Author 's abstract)
Associations of Occupational Attributes and Excessive Drinking
Barnes, Andrew J.; Zimmerman, Frederick J.
2017-01-01
Numerous work-related drinking mechanisms have been posited and, oftentimes, examined in isolation. We combined data from over 100 occupational attributes into several factors and tested the association of these factors with measures of alcohol use. We used the NLSY79 2006 wave, a U.S. representative sample of 6,426 workers ages 41 to 49 and the 2006 Occupational Information Network database (O*NET), a nationally representative sample of nearly 1,000 occupations. We conducted exploratory factor analysis on 119 occupational attributes and found three independent workplace characteristics – physical demands, job autonomy, and social engagement - explained the majority of the variation. We then tested the association of these composite attributes with three drinking measures, before and after adjusting for gender, race/ethnicity, and a measure of human capital using count data models. We then stratified by gender and repeated our analyses. Men working in occupations with a one standard deviation higher level of physical demand (e.g. construction) reported a higher number of heavy drinking occasions (+20%, p<0.05). Job autonomy was not significantly associated with measures of alcohol use and when the combined association of higher levels of physical demand and lower levels of job autonomy was examined, modest support for job strain as a mechanism for work-related alcohol consumption was found. In our pooled sample, working in occupations with one standard deviation higher levels of social engagement was associated with lower numbers of drinking days (−9%, p<0.05) after adjustment. Physical demand and social engagement were associated with alcohol consumption measures but these relationships varied by workers’ gender. Future areas of research should include confirmatory analyses using other waves of O*Net data and replicating the current analysis in other samples of workers. If our results are validated, they suggest male workers in high physical demand occupations could be targets for intervention. PMID:23849277
Hakimé, Antoine; Peddi, Himaja; Hines-Peralta, Andrew U; Wilcox, Carol J; Kruskal, Jonathan; Lin, Shezhang; de Baere, Thierry; Raptopoulos, Vassilios D; Goldberg, S Nahum
2007-06-01
To prospectively compare single- and multisection computed tomographic (CT) perfusion for tumor blood flow determination in an animal model. All animal protocols and experiments were approved by the institutional animal care and use committee before the study was initiated. R3230 mammary adenocarcinoma was implanted in 11 rats. Tumors (18-20 mm) were scanned with dynamic 16-section CT at baseline and after administration of arsenic trioxide, which is known to cause acute reduction in blood flow. The concentration of arsenic was titrated (0-6 mg of arsenic per kilogram of body weight) to achieve a defined blood flow reduction (0%-75%) from baseline levels at 60 minutes, as determined with correlative laser Doppler flowmetry. The mean blood flow was calculated for each of four 5-mm sections that covered the entire tumor, as well as for the entire tumor after multiple sections were processed. Measurements obtained with both methods were correlated with laser Doppler flowmetry measurements. Interobserver agreement was determined for two blinded radiologists, who calculated the percentage of blood flow reduction for the "most representative" single sections at baseline and after arsenic administration. These results were compared with the interobserver variability of the same radiologists obtained by summing blood flow changes for the entire tumor volume. Overall correlations for acute blood flow reduction were demonstrated between laser Doppler flowmetry and the two CT perfusion approaches (single-section CT, r=0.85 and r(2)=0.73; multisection CT, r=0.93 and r(2)=0.87; pooled data, P=.01). CT perfusion disclosed marked heterogeneity of blood flow, with variations of 36% +/- 13 between adjacent 5-mm sections. Given these marked differences, interobserver agreement was much lower for single-section CT (standard deviation, 0.22) than for multisection CT (standard deviation, 0.10; P=.01). Multisection CT perfusion techniques may provide an accurate and more reproducible method of tumor perfusion surveillance than comparison of single representative tumor sections. (c) RSNA, 2007.
NASA Technical Reports Server (NTRS)
Spera, David A.
2008-01-01
Equations are developed with which to calculate lift and drag coefficients along the spans of torsionally-stiff rotating airfoils of the type used in wind turbine rotors and wind tunnel fans, at angles of attack in both the unstalled and stalled aerodynamic regimes. Explicit adjustments are made for the effects of aspect ratio (length to chord width) and airfoil thickness ratio. Calculated lift and drag parameters are compared to measured parameters for 55 airfoil data sets including 585 test points. Mean deviation was found to be -0.4 percent and standard deviation was 4.8 percent. When the proposed equations were applied to the calculation of power from a stall-controlled wind turbine tested in a NASA wind tunnel, mean deviation from 54 data points was -1.3 percent and standard deviation was 4.0 percent. Pressure-rise calculations for a large wind tunnel fan deviated by 2.7 percent (mean) and 4.4 percent (standard). The assumption that a single set of lift and drag coefficient equations can represent the stalled aerodynamic behavior of a wide variety of airfoils was found to be satisfactory.
AN INFERENTIAL INDEX OF SWIMMING POOL PURITY
Fair, Gordon M.
1920-01-01
Score cards for swimming pools is the suggestion of this paper. Figures about these establishments are today in the class with crude statistics, and may lead to unreliable conclusions. Here are suggested various indexes which may be of service in framing minimum requirements for these pools. This article is an effort to clear up a complicated matter for which there are not now accepted standards. PMID:18010324
Attention deficit/hyperactivity disorder and risk of injuries: A systematic review and meta-analysis
Amiri, Shahrokh; Sadeghi-Bazargani, Homayoun; Nazari, Soulmaz; Ranjbar, Fatemeh; Abdi, Salman
2017-01-01
Abstract: Background: This study systematically reviewed the literature in order to determine the effect of Attention-Deficit Hyperactivity Disorder (ADHD) on injuries and assessed the magnitude of the potential association. Methods: A systematic review of the studies examining the association of ADHD and injuries was carried out across multiple databases. Odds ratios and standardized mean differences were pooled. Results: A total of 35 studies were selected for quantitative analysis. The association of ADHD and injuries was confirmed over the meta-analysis of eligible studies. The odds ratio pooled over all comparative studies was 1.96(95% CI: 1.6-2.4) using random effects model. Pooled odds ratio of 2.1 and 2.17 were calculated respectively when cohort and case-control studies or just cohort studies were included. The pooled odds ratio reduced to 1.8(CI:1.45-2.3) when studies on specific injuries were removed. For studies comparing scores of rating scales, the pooled standardized mean difference was 0.61(95% CI: 0.03-1.2). Conclusions: Those with ADHD are nearly two times more likely to be injured. PMID:28554188
Seay, Joseph F.; Gregorczyk, Karen N.; Hasselquist, Leif
2016-01-01
Abstract Influences of load carriage and inclination on spatiotemporal parameters were examined during treadmill and overground walking. Ten soldiers walked on a treadmill and overground with three load conditions (00 kg, 20 kg, 40 kg) during level, uphill (6% grade) and downhill (-6% grade) inclinations at self-selected speed, which was constant across conditions. Mean values and standard deviations for double support percentage, stride length and a step rate were compared across conditions. Double support percentage increased with load and inclination change from uphill to level walking, with a 0.4% stance greater increase at the 20 kg condition compared to 00 kg. As inclination changed from uphill to downhill, the step rate increased more overground (4.3 ± 3.5 steps/min) than during treadmill walking (1.7 ± 2.3 steps/min). For the 40 kg condition, the standard deviations were larger than the 00 kg condition for both the step rate and double support percentage. There was no change between modes for step rate standard deviation. For overground compared to treadmill walking, standard deviation for stride length and double support percentage increased and decreased, respectively. Changes in the load of up to 40 kg, inclination of 6% grade away from the level (i.e., uphill or downhill) and mode (treadmill and overground) produced small, yet statistically significant changes in spatiotemporal parameters. Variability, as assessed by standard deviation, was not systematically lower during treadmill walking compared to overground walking. Due to the small magnitude of changes, treadmill walking appears to replicate the spatiotemporal parameters of overground walking. PMID:28149338
Hopper, John L
2015-11-15
How can the "strengths" of risk factors, in the sense of how well they discriminate cases from controls, be compared when they are measured on different scales such as continuous, binary, and integer? Given that risk estimates take into account other fitted and design-related factors-and that is how risk gradients are interpreted-so should the presentation of risk gradients. Therefore, for each risk factor X0, I propose using appropriate regression techniques to derive from appropriate population data the best fitting relationship between the mean of X0 and all the other covariates fitted in the model or adjusted for by design (X1, X2, … , Xn). The odds per adjusted standard deviation (OPERA) presents the risk association for X0 in terms of the change in risk per s = standard deviation of X0 adjusted for X1, X2, … , Xn, rather than the unadjusted standard deviation of X0 itself. If the increased risk is relative risk (RR)-fold over A adjusted standard deviations, then OPERA = exp[ln(RR)/A] = RR(s). This unifying approach is illustrated by considering breast cancer and published risk estimates. OPERA estimates are by definition independent and can be used to compare the predictive strengths of risk factors across diseases and populations. © The Author 2015. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Maassen, Gerard H
2010-08-01
In this Journal, Lewis and colleagues introduced a new Reliable Change Index (RCI(WSD)), which incorporated the within-subject standard deviation (WSD) of a repeated measurement design as the standard error. In this note, two opposite errors in using WSD this way are demonstrated. First, being the standard error of measurement of only a single assessment makes WSD too small when practice effects are absent. Then, too many individuals will be designated reliably changed. Second, WSD can grow unlimitedly to the extent that differential practice effects occur. This can even make RCI(WSD) unable to detect any reliable change.
Gender Differences in Numeracy in Indonesia: Evidence from a Longitudinal Dataset
ERIC Educational Resources Information Center
Suryadarma, Daniel
2015-01-01
This paper uses a rich longitudinal dataset to measure the evolution of the gender differences in numeracy among school-age children in Indonesia. Girls outperformed boys by 0.08 standard deviations when the sample was around 11 years old. Seven years later, the gap has widened to 0.19 standard deviations, equivalent to around 18 months of…
A Survey Data Response to the Teaching of Utility Curves and Risk Aversion
ERIC Educational Resources Information Center
Hobbs, Jeffrey; Sharma, Vivek
2011-01-01
In many finance and economics courses as well as in practice, the concept of risk aversion is reduced to the standard deviation of returns, whereby risk-averse investors prefer to minimize their portfolios' standard deviations. In reality, the concept of risk aversion is richer and more interesting than this, and can easily be conveyed through…
On the Linear Relation between the Mean and the Standard Deviation of a Response Time Distribution
ERIC Educational Resources Information Center
Wagenmakers, Eric-Jan; Brown, Scott
2007-01-01
Although it is generally accepted that the spread of a response time (RT) distribution increases with the mean, the precise nature of this relation remains relatively unexplored. The authors show that in several descriptive RT distributions, the standard deviation increases linearly with the mean. Results from a wide range of tasks from different…
Kallio, Heikki; Nylund, Matts; Boström, Pontus; Yang, Baoru
2017-10-15
A highly sensitive mass spectrometric (MS) method was developed and validated to analyze ratios of regioisomeric triacylglycerols (TAGs) in fats and oils. UPLC resolution of lithiated TAGs followed by daughter scan MS/MS of positive ions revealed several indicative ions for quantitative analysis. Reference TAGs containing C14-C20 fatty acids (FAs) showed good linear response. Analysis of Finnish and Chinese pooled human milk samples revealed hundreds of regioisomeric TAGs. At least 64mol% of the TAGs were quantified with relative standard deviation <17%. When present in the same TAG molecule together with C18 FAs, palmitic acid was typically in the sn-2 position. When together with FAs 10:0, 12:0, 14:0, 20:1 and 20:2, the sn-2 preference of 16:0 was less clear. Oleic acid occupied typically the sn-1/sn-3 positions but when together with FAs 20:1, 20:2, 18:2, 14:1, 12:0 or 10:0 the positioning of 18:1 did not follow these rules. Copyright © 2017. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Meador, Travis B.; Aluwihare, Lihini I.
2014-10-01
In North Atlantic waters impacted by discharges from the Amazon and Orinoco Rivers, where planktonic diatom-diazotroph associations (DDA) were active, we observed that an average (± standard deviation) of 61 ± 12% of the biological drawdown of dissolved inorganic carbon (DIC) was partitioned into the accumulating total organic carbon pool, representing a flux of up to 9 ± 4 Tg C yr-1. This drawdown corresponded with chemical alteration of ultrafiltered dissolved organic matter (UDOM), including increases in stable C isotopic composition (δ13C) and C:N. The dissolved carbohydrate component of UDOM also increased with biological DIC drawdown and diatom-associated diazotroph (i.e., Richelia) abundance. New carbohydrates could be distinguished by distinctively high relative abundances of deoxy sugars (up to 55% of monosaccharides), which may promote aggregate formation and enhance vertical carbon export. The identified production of non-Redfieldian, C-enriched UDOM thus suggests a mechanism to explain enhanced C sequestration associated with DDA N2 fixation, which may be widespread in mesohaline environments.
Some statistical investigations on the nature and dynamics of electricity prices
NASA Astrophysics Data System (ADS)
Bottazzi, G.; Sapio, S.; Secchi, A.
2005-09-01
This work analyzes the log-returns of daily electricity prices from the NordPool day-ahead market. We study both the unconditional growth rates distribution and the distribution of residual shocks obtained with a non-parametric filtering procedure based on the Cholesky factor algorithm. We show that, even if the Subbotin family of distributions is able to describe the empirical observations in both cases, the Subbotin fit obtained for the unconditional growth rates and for the residual shocks reveal significant differences. Indeed, the sequence of log-returns can be described as the outcome of an aggregation of Laplace-distributed shocks with time-dependent volatility. We find that the standard deviation of shocks scales as a power law of the initial price level, with scaling exponent around -1. Moreover, the analysis of the empirical density of shocks, conditional on the price level, shows a strong relationship of the Subbotin fit with the latter. We conclude that the unconditional growth rates distribution is the superposition of shocks distributions characterized by decreasing volatility and fat-tailedness with respect to the price level.
Yarazavi, Mina; Noroozian, Ebrahim
2018-02-13
A novel sol-gel coating on a stainless-steel fiber was developed for the first time for the headspace solid-phase microextraction and determination of α-bisabolol with gas chromatography and flame ionization detection. The parameters influencing the efficiency of solid-phase microextraction process, such as extraction time and temperature, pH, and ionic strength, were optimized by the experimental design method. Under optimized conditions, the linear range was between 0.0027 and 100 μg/mL. The relative standard deviations determined at 0.01 and 1.0 μg/mL concentration levels (n = 3), respectively, were as follows: intraday relative standard deviations 3.4 and 3.3%; interday relative standard deviations 5.0 and 4.3%; and fiber-to-fiber relative standard deviations 6.0 and 3.5%. The relative recovery values were 90.3 and 101.4% at 0.01 and 1.0 μg/mL spiking levels, respectively. The proposed method was successfully applied to various real samples containing α-bisabolol. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Weigel, Stefan; Peters, Ruud; Loeschner, Katrin; Grombe, Ringo; Linsinger, Thomas P J
2017-08-01
Single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS) promises fast and selective determination of nanoparticle size and number concentrations. While several studies on practical applications have been published, data on formal, especially interlaboratory validation of sp-ICP-MS, is sparse. An international interlaboratory study was organized to determine repeatability and reproducibility of the determination of the median particle size and particle number concentration of Ag nanoparticles (AgNPs) in chicken meat. Ten laboratories from the European Union, the USA, and Canada determined particle size and particle number concentration of two chicken meat homogenates spiked with polyvinylpyrrolidone (PVP)-stabilized AgNPs. For the determination of the median particle diameter, repeatability standard deviations of 2 and 5% were determined, and reproducibility standard deviations were 15 and 25%, respectively. The equivalent median diameter itself was approximately 60% larger than the diameter of the particles in the spiking solution. Determination of the particle number concentration was significantly less precise, with repeatability standard deviations of 7 and 18% and reproducibility standard deviations of 70 and 90%.
Estimation of Tooth Size Discrepancies among Different Malocclusion Groups
Bala, Madhu; Goyal, Virender
2014-01-01
ABSTRACT Regards and Tribute: Late Dr Narender Hasija was a mentor and visionary in the light of knowledge and experience. We pay our regards with deepest gratitude to the departed soul to rest in peace. Bolton’s ratios help in estimating overbite, overjet relationships, the effects of contemplated extractions on posterior occlusion, incisor relationships and identification of occlusal misfit produced by tooth size discrepancies. Aim: To determine any difference in tooth size discrepancy in anterior as well as overall ratio in different malocclusions and comparison with Bolton’s study. Materials and methods: After measuring the teeth on all 100 patients, Bolton’s analysis was performed. Results were compared with Bolton’s means and standard deviations. The results were also subjected to statistical analysis. Results show that the mean and standard deviations of ideal occlusion cases are comparable with those Bolton but, when the mean and standard deviation of malocclusion groups are compared with those of Bolton, the values of standard deviation are higher, though the mean is comparable. How to cite this article: Hasija N, Bala M, Goyal V. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups. Int J Clin Pediatr Dent 2014;7(2):82-85. PMID:25356005
McKenna, D; Kadidlo, D; Sumstad, D; McCullough, J
2003-01-01
Errors and accidents, or deviations from standard operating procedures, other policy, or regulations must be documented and reviewed, with corrective actions taken to assure quality performance in a cellular therapy laboratory. Though expectations and guidance for deviation management exist, a description of the framework for the development of such a program is lacking in the literature. Here we describe our deviation management program, which uses a Microsoft Access database and Microsoft Excel to analyze deviations and notable events, facilitating quality assurance (QA) functions and ongoing process improvement. Data is stored in a Microsoft Access database with an assignment to one of six deviation type categories. Deviation events are evaluated for potential impact on patient and product, and impact scores for each are determined using a 0- 4 grading scale. An immediate investigation occurs, and corrective actions are taken to prevent future similar events from taking place. Additionally, deviation data is collectively analyzed on a quarterly basis using Microsoft Excel, to identify recurring events or developing trends. Between January 1, 2001 and December 31, 2001 over 2500 products were processed at our laboratory. During this time period, 335 deviations and notable events occurred, affecting 385 products and/or patients. Deviations within the 'technical error' category were most common (37%). Thirteen percent of deviations had a patient and/or a product impact score > or = 2, a score indicating, at a minimum, potentially affected patient outcome or moderate effect upon product quality. Real-time analysis and quarterly review of deviations using our deviation management program allows for identification and correction of deviations. Monitoring of deviation trends allows for process improvement and overall successful functioning of the QA program in the cell therapy laboratory. Our deviation management program could serve as a model for other laboratories in need of such a program.
Xiong, Dan-Dan; Feng, Zhen-Bo; Cen, Wei-Luan; Zeng, Jing-Jing; Liang, Lu; Tang, Rui-Xue; Gan, Xiao-Ning; Liang, Hai-Wei; Li, Zu-Yun; Chen, Gang; Luo, Dian-Zhong
2017-03-14
This comprehensive investigation was performed to evaluate the expression level and potential clinical value of NEAT1 in digestive system malignancies. A total of 57 lncRNA datasets of microarray or RNA-seq and 5 publications were included. The pooled standard mean deviation (SMD) indicated that NEAT1 was down-regulated in esophageal carcinoma (ESCA, SMD = -0.35, 95% CI: -0.5~-0.20, P < 0.0001) and hepatocellular carcinoma (HCC, SMD = -0.47, 95% CI: -0.60~-0.34, P < 0.0001), while in pancreatic cancer (PC), NEAT1 was up-regulated (SMD = 0.45, 95% CI: 0.2~0.71, P = 0.001). However, NEAT1 expression in gastric cancer (GC), colorectal cancer (CRC), biliary tract cancer (BTC) and gallbladder carcinoma (GBC) showed no significant difference between cancer and control groups. The pooled area under the curve values for ESCA, GC, CRC, PC and HCC were 0.60, 0.89, 0.81, 0.77 and 0.69, respectively. Furthermore, our result demonstrated that a high expression of NEAT1 predicted an unfavorable prognosis in patients with digestive system malignancies (HR: 1.50, 95% CI: 1.28-1.76, P < 0.0001). Our study suggests that NEAT1 may play different roles in the initiation and progression of digestive system cancers and could be a potential diagnostic and prognostic biomarker in patients with digestive system carcinomas. Further and stricter studies with a larger number of cases are necessary to strengthen our conclusions.
Cen, Wei-Luan; Zeng, Jing-Jing; Liang, Lu; Tang, Rui-Xue; Gan, Xiao-Ning; Liang, Hai-Wei; Li, Zu-Yun; Chen, Gang; Luo, Dian-Zhong
2017-01-01
This comprehensive investigation was performed to evaluate the expression level and potential clinical value of NEAT1 in digestive system malignancies. A total of 57 lncRNA datasets of microarray or RNA-seq and 5 publications were included. The pooled standard mean deviation (SMD) indicated that NEAT1 was down-regulated in esophageal carcinoma (ESCA, SMD = −0.35, 95% CI: −0.5~-0.20, P < 0.0001) and hepatocellular carcinoma (HCC, SMD = −0.47, 95% CI: −0.60~-0.34, P < 0.0001), while in pancreatic cancer (PC), NEAT1 was up-regulated (SMD = 0.45, 95% CI: 0.2~0.71, P = 0.001). However, NEAT1 expression in gastric cancer (GC), colorectal cancer (CRC), biliary tract cancer (BTC) and gallbladder carcinoma (GBC) showed no significant difference between cancer and control groups. The pooled area under the curve values for ESCA, GC, CRC, PC and HCC were 0.60, 0.89, 0.81, 0.77 and 0.69, respectively. Furthermore, our result demonstrated that a high expression of NEAT1 predicted an unfavorable prognosis in patients with digestive system malignancies (HR: 1.50, 95% CI: 1.28-1.76, P < 0.0001). Our study suggests that NEAT1 may play different roles in the initiation and progression of digestive system cancers and could be a potential diagnostic and prognostic biomarker in patients with digestive system carcinomas. Further and stricter studies with a larger number of cases are necessary to strengthen our conclusions. PMID:28118609
Jokela, M; Hintsanen, M; Hakulinen, C; Batty, G D; Nabi, H; Singh-Manoux, A; Kivimäki, M
2013-04-01
Personality is thought to affect obesity risk but before such information can be incorporated into prevention and intervention plans, robust and converging evidence concerning the most relevant personality traits is needed. We performed a meta-analysis based on individual-participant data from nine cohort studies to examine whether broad-level personality traits predict the development and persistence of obesity (n = 78,931 men and women; mean age 50 years). Personality was assessed using inventories of the Five-Factor Model (extraversion, neuroticism, agreeableness, conscientiousness and openness to experience). High conscientiousness - reflecting high self-control, orderliness and adherence to social norms - was associated with lower obesity risk across studies (pooled odds ratio [OR] = 0.84; 95% confidence interval [CI] = 0.80-0.88 per 1 standard deviation increment in conscientiousness). Over a mean follow-up of 5.4 years, conscientiousness predicted lower obesity risk in initially non-obese individuals (OR = 0.88, 95% CI = 0.85-0.92; n = 33,981) and was associated with greater likelihood of reversion to non-obese among initially obese individuals (OR = 1.08, 95% CI = 1.01-1.14; n = 9,657). Other personality traits were not associated with obesity in the pooled analysis, and there was substantial heterogeneity in the associations between studies. The findings indicate that conscientiousness may be the only broad-level personality trait of the Five-Factor Model that is consistently associated with obesity across populations. © 2012 The Authors. obesity reviews © 2012 International Association for the Study of Obesity.
Elevated triglycerides may affect cystatin C recovery.
Witzel, Samantha H; Butts, Katherine; Filler, Guido
2014-05-01
The purpose of this study was to investigate the effect of triglyceride concentration on cystatin C (CysC) measurements. Serum samples collected from 10 nephrology patients, 43 to 78years of age, were air centrifuged to separate aqueous and lipid layers. The lipid layer from each patient was pooled together to create a mixture with a high triglyceride concentration. This pooled lipid layer was mixed with each of the ten patient aqueous layers in six different ratios. Single factor ANOVA was used to assess whether CysC recovery was affected by triglyceride levels. Regression analysis was used to develop a formula to correct for the effect of triglycerides on CysC measurement, based on samples from 6 randomly chosen patients from our study population. The formula was validated with the 4 remaining samples. The analysis revealed a significant reduction in measured CysC with increasing concentrations of triglycerides (Pearson r=-0.56, p<0.0001). The following formula was developed to correct for the effect of triglycerides: Subsequent Bland-Altman plots revealed a bias (mean±1 standard deviation [SD]) of -3.7±15.6% for the data used to generate the correction formula and a bias of 3.52±9.38% for the validation set. Our results suggest that triglyceride concentrations significantly impact cystatin C measurements and that this effect may be corrected in samples that cannot be sufficiently clarified by air centrifugation using the equation that we developed. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Local and regional species diversity of benthic Isopoda (Crustacea) in the deep Gulf of Mexico
NASA Astrophysics Data System (ADS)
Wilson, George D. F.
2008-12-01
Recent studies of deep-sea faunas considered the influence of mid-domain models in the distribution of species diversity and richness with depth. In this paper, I show that separating local diversity from regional species richness in benthic isopods clarifies mid-domain effects in the distribution of isopods in the Gulf of Mexico. Deviations from the randomised implied species ranges can be informative to understanding general patterns within the Gulf of Mexico. The isopods from the GoMB study contained 135 species, with a total of 156 species including those from an earlier study. More than 60 species may be new to science. Most families of deep-sea isopods (suborder Asellota) were present, although some were extremely rare. The isopod family Desmosomatidae dominated the samples, and one species of Macrostylis (Macrostylidae) was found in many samples. Species richness for samples pooled within sites ranged from 1 to 52 species. Because species in pooled samples were highly correlated with individuals, species diversity was compared across sites using the expected species estimator ( n=15 individuals, ES 15). Six depth transects had idiosyncratic patterns of ES 15, and transects with the greatest short-range variation in topography, such as basins and canyons, had the greatest short-range disparity. Basins on the deep slope did not have a consistent influence (i.e., relatively higher or lower than surrounding areas) on the comparative species diversity. ES 15 of all transects together showed a weak mid-domain effect, peaking around 1200-1500 m, with low values at the shallowest and deepest samples (Sigsbee Abyssal Plain); no longitudinal (east-west) pattern was found. The regional species pool was analyzed by summing the implied ranges of all species. The species ranges in aggregate did not have significant patterns across longitudes, and many species had broad depth ranges, suggesting that the isopod fauna of the Gulf of Mexico is well dispersed. The summed ranges, as expected, had strong mid-domain patterns, contrasting with the local species richness estimates. The longitudinal ranges closely matched a randomized pattern (species ranges placed randomly, 1000 iterations), with significant deviations in the east attributable to lower sampling effort. The depth pattern, however, deviated from the mid-domain model, with a bimodal peak displaced nearly 500 m shallower than the mode of the randomized distribution. The deviations from random expectation were significantly positive above 1600 m and negative below 2000 m, with the result that regional species richness peaked between 800 and 1200 m, and decreased rapidly at deeper depths. The highest species richness intervals corresponded to the number of individuals collected. Residuals from a regression of the deviations on individual numbers, however, still deviated from the randomized pattern. In this declining depth-diversity pattern, the Gulf of Mexico resembles other partially enclosed basins, such as the Norwegian Sea, known to have suffered geologically recent extinction events. This displaced diversity pattern and broad depth ranges implicate ongoing re-colonization of the deeper parts of the Gulf of Mexico. The Sigsbee Abyssal Plain sites could be depauperate for historical reasons (e.g., one or more extinction events) rather than ongoing ecological reasons (e.g., low food supply).
Ku-band radar threshold analysis
NASA Technical Reports Server (NTRS)
Weber, C. L.; Polydoros, A.
1979-01-01
The statistics of the CFAR threshold for the Ku-band radar was determined. Exact analytical results were developed for both the mean and standard deviations in the designated search mode. The mean value is compared to the results of a previously reported simulation. The analytical results are more optimistic than the simulation results, for which no explanation is offered. The normalized standard deviation is shown to be very sensitive to signal-to-noise ratio and very insensitive to the noise correlation present in the range gates of the designated search mode. The substantial variation in the CFAR threshold is dominant at large values of SNR where the normalized standard deviation is greater than 0.3. Whether or not this significantly affects the resulting probability of detection is a matter which deserves additional attention.
Hart, John
2011-03-01
This study describes a model for statistically analyzing follow-up numeric-based chiropractic spinal assessments for an individual patient based on his or her own baseline. Ten mastoid fossa temperature differential readings (MFTD) obtained from a chiropractic patient were used in the study. The first eight readings served as baseline and were compared to post-adjustment readings. One of the two post-adjustment MFTD readings fell outside two standard deviations of the baseline mean and therefore theoretically represents improvement according to pattern analysis theory. This study showed how standard deviation analysis may be used to identify future outliers for an individual patient based on his or her own baseline data. Copyright © 2011 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
1980-03-14
failure Sigmar (Or) in line 50, the standard deviation of the relative error of the weights Sigmap (o) in line 60, the standard deviation of the phase...200, the weight structures in the x and y coordinates Q in line 210, the probability of element failure Sigmar (Or) in line 220, the standard...NUMBER OF ELEMENTS =u;2*H 120 PRINT "Pr’obability of elemenit failure al;O 130 PRINT "Standard dtvi&t ion’ oe r.1&tive ýrror of wl; Sigmar 14 0 PRINT
Cooling Rate Determination in Additively Manufactured Aluminum Alloy 2219
NASA Astrophysics Data System (ADS)
Brice, Craig A.; Dennis, Noah
2015-05-01
Metallic additive manufacturing processes generally utilize a conduction mode, welding-type approach to create beads of deposited material that can be arranged into a three-dimensional structure. As with welding, the cooling rates in the molten pool are relatively rapid compared to traditional casting techniques. Determination of the cooling rate in the molten pool is critical for predicting the solidified microstructure and resultant properties. In this experiment, wire-fed electron beam additive manufacturing was used to melt aluminum alloy 2219 under different thermal boundary conditions. The dendrite arm spacing was measured in the remelted material, and this information was used to estimate cooling rates in the molten pool based on established empirical relationships. The results showed that the thermal boundary conditions have a significant effect on the resulting cooling rate in the molten pool. When thermal conduction is limited due to a small thermal sink, the dendrite arm spacing varies between 15 and 35 µm. When thermal conduction is active, the dendrite arm spacing varies between 6 and 12 µm. This range of dendrite arm spacing implies cooling rates ranging from 5 to 350 K/s. Cooling rates can vary greatly as thermal conditions change during deposition. A cooling rate at the higher end of the range could lead to significant deviation from microstructural equilibrium during solidification.
Takarabe, S; Yabuuchi, H; Morishita, J
2012-06-01
To investigate the usefulness of the standard deviation of pixel values in a whole mammary glands region and the percentage of a high- density mammary glands region to a whole mammary glands region as features for classification of mammograms into four categories based on the ACR BI-RADS breast composition. We used 36 digital mediolateral oblique view mammograms (18 patients) approved by our IRB. These images were classified into the four categories of breast compositions by an experienced breast radiologist and the results of the classification were regarded as a gold standard. First, a whole mammary region in a breast was divided into two regions such as a high-density mammary glands region and a low/iso-density mammary glands region by using a threshold value that was obtained from the pixel values corresponding to a pectoral muscle region. Then the percentage of a high-density mammary glands region to a whole mammary glands region was calculated. In addition, as a new method, the standard deviation of pixel values in a whole mammary glands region was calculated as an index based on the intermingling of mammary glands and fats. Finally, all mammograms were classified by using the combination of the percentage of a high-density mammary glands region and the standard deviation of each image. The agreement rates of the classification between our proposed method and gold standard was 86% (31/36). This result signified that our method has the potential to classify mammograms. The combination of the standard deviation of pixel values in a whole mammary glands region and the percentage of a high-density mammary glands region to a whole mammary glands region was available as features to classify mammograms based on the ACR BI- RADS breast composition. © 2012 American Association of Physicists in Medicine.
40 CFR 63.7951 - What reports must I submit and when?
Code of Federal Regulations, 2010 CFR
2010-07-01
... the information in § 63.10(d)(5)(i). (5) If there were no deviations from any emissions limitations... that there were no deviations from the emissions limitations, work practice standards, or operation and...) For each deviation from an emissions limitation (including an operating limit) that occurs at an...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gupta, N; DiCostanzo, D; Fullenkamp, M
2015-06-15
Purpose: To determine appropriate couch tolerance values for modern radiotherapy linac R&V systems with indexed patient setup. Methods: Treatment table tolerance values have been the most difficult to lower, due to many factors including variations in patient positioning and differences in table tops between machines. We recently installed nine linacs with similar tables and started indexing every patient in our clinic. In this study we queried our R&V database and analyzed the deviation of couch position values from the acquired values at verification simulation for all patients treated with indexed positioning. Mean and standard deviations of daily setup deviations weremore » computed in the longitudinal, lateral and vertical direction for 343 patient plans. The mean, median and standard error of the standard deviations across the whole patient population and for some disease sites were computed to determine tolerance values. Results: The plot of our couch deviation values showed a gaussian distribution, with some small deviations, corresponding to setup uncertainties on non-imaging days, and SRS/SRT/SBRT patients, as well as some large deviations which were spot checked and found to be corresponding to indexing errors that were overriden. Setting our tolerance values based on the median + 1 standard error resulted in tolerance values of 1cm lateral and longitudinal, and 0.5 cm vertical for all non- SRS/SRT/SBRT cases. Re-analizing the data, we found that about 92% of the treated fractions would be within these tolerance values (ignoring the mis-indexed patients). We also analyzed data for disease site based subpopulations and found no difference in the tolerance values that needed to be used. Conclusion: With the use of automation, auto-setup and other workflow efficiency tools being introduced into radiotherapy workflow, it is very essential to set table tolerances that allow safe treatments, but flag setup errors that need to be reassessed before treatments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aaboud, M.; Aad, G.; Abbott, B.
Here, a search for the associated production of the Higgs boson with a top quark pair (more » $$t\\bar{t}$$H) is reported. The search is performed in multilepton final states using a data set corresponding to an integrated luminosity of 36.1 fb -1 of proton-proton collision data recorded by the ATLAS experiment at a center-of-mass energy $$\\sqrt{s}$$ = 13 TeV at the Large Hadron Collider. Higgs boson decays to WW*, ττ, and ZZ* are targeted. Seven final states, categorized by the number and flavor of charged-lepton candidates, are examined for the presence of the Standard Model Higgs boson with a mass of 125 GeV and a pair of top quarks. An excess of events over the expected background from Standard Model processes is found with an observed significance of 4.1 standard deviations, compared to an expectation of 2.8 standard deviations. The best fit for the $$t\\bar{t}$$H production cross section is σ($$t\\bar{t}$$H) = $${790}_{-210}^{+230}$$ fb, in agreement with the Standard Model prediction of $${507}_{-50}^{+35}$$ fb. The combination of this result with other $$t\\bar{t}$$H searches from the ATLAS experiment using the Higgs boson decay modes to $$b\\bar{b}$$, γγ and ZZ* → 4ℓ, has an observed significance of 4.2 standard deviations, compared to an expectation of 3.8 standard deviations. This provides evidence for the $$t\\bar{t}$$H production mode.« less
Aaboud, M.; Aad, G.; Abbott, B.; ...
2018-04-09
Here, a search for the associated production of the Higgs boson with a top quark pair (more » $$t\\bar{t}$$H) is reported. The search is performed in multilepton final states using a data set corresponding to an integrated luminosity of 36.1 fb -1 of proton-proton collision data recorded by the ATLAS experiment at a center-of-mass energy $$\\sqrt{s}$$ = 13 TeV at the Large Hadron Collider. Higgs boson decays to WW*, ττ, and ZZ* are targeted. Seven final states, categorized by the number and flavor of charged-lepton candidates, are examined for the presence of the Standard Model Higgs boson with a mass of 125 GeV and a pair of top quarks. An excess of events over the expected background from Standard Model processes is found with an observed significance of 4.1 standard deviations, compared to an expectation of 2.8 standard deviations. The best fit for the $$t\\bar{t}$$H production cross section is σ($$t\\bar{t}$$H) = $${790}_{-210}^{+230}$$ fb, in agreement with the Standard Model prediction of $${507}_{-50}^{+35}$$ fb. The combination of this result with other $$t\\bar{t}$$H searches from the ATLAS experiment using the Higgs boson decay modes to $$b\\bar{b}$$, γγ and ZZ* → 4ℓ, has an observed significance of 4.2 standard deviations, compared to an expectation of 3.8 standard deviations. This provides evidence for the $$t\\bar{t}$$H production mode.« less
NASA Astrophysics Data System (ADS)
Aaboud, M.; Aad, G.; Abbott, B.; Abdinov, O.; Abeloos, B.; Abidi, S. H.; Abouzeid, O. S.; Abraham, N. L.; Abramowicz, H.; Abreu, H.; Abulaiti, Y.; Acharya, B. S.; Adachi, S.; Adamczyk, L.; Adelman, J.; Adersberger, M.; Adye, T.; Affolder, A. A.; Afik, Y.; Agheorghiesei, C.; Aguilar-Saavedra, J. A.; Ahlen, S. P.; Ahmadov, F.; Aielli, G.; Akatsuka, S.; Åkesson, T. P. A.; Akilli, E.; Akimov, A. V.; Alberghi, G. L.; Albert, J.; Albicocco, P.; Alconada Verzini, M. J.; Alderweireldt, S. C.; Aleksa, M.; Aleksandrov, I. N.; Alexa, C.; Alexander, G.; Alexopoulos, T.; Alhroob, M.; Ali, B.; Aliev, M.; Alimonti, G.; Alison, J.; Alkire, S. P.; Allaire, C.; Allbrooke, B. M. M.; Allen, B. W.; Allport, P. P.; Aloisio, A.; Alonso, A.; Alonso, F.; Alpigiani, C.; Alshehri, A. A.; Alstaty, M. I.; Alvarez Gonzalez, B.; Álvarez Piqueras, D.; Alviggi, M. G.; Amadio, B. T.; Amaral Coutinho, Y.; Ambroz, L.; Amelung, C.; Amidei, D.; Amor Dos Santos, S. P.; Amoroso, S.; Anastopoulos, C.; Ancu, L. S.; Andari, N.; Andeen, T.; Anders, C. F.; Anders, J. K.; Anderson, K. J.; Andreazza, A.; Andrei, V.; Angelidakis, S.; Angelozzi, I.; Angerami, A.; Anisenkov, A. V.; Annovi, A.; Antel, C.; Antonelli, M.; Antonov, A.; Antrim, D. J.; Anulli, F.; Aoki, M.; Aperio Bella, L.; Arabidze, G.; Arai, Y.; Araque, J. P.; Araujo Ferraz, V.; Arce, A. T. H.; Ardell, R. E.; Arduh, F. A.; Arguin, J.-F.; Argyropoulos, S.; Armbruster, A. J.; Armitage, L. J.; Arnaez, O.; Arnold, H.; Arratia, M.; Arslan, O.; Artamonov, A.; Artoni, G.; Artz, S.; Asai, S.; Asbah, N.; Ashkenazi, A.; Asquith, L.; Assamagan, K.; Astalos, R.; Atkin, R. J.; Atkinson, M.; Atlay, N. B.; Augsten, K.; Avolio, G.; Avramidou, R.; Axen, B.; Ayoub, M. K.; Azuelos, G.; Baas, A. E.; Baca, M. J.; Bachacou, H.; Bachas, K.; Backes, M.; Bagnaia, P.; Bahmani, M.; Bahrasemani, H.; Baines, J. T.; Bajic, M.; Baker, O. K.; Bakker, P. J.; Bakshi Gupta, D.; Baldin, E. M.; Balek, P.; Balli, F.; Balunas, W. K.; Banas, E.; Bandyopadhyay, A.; Banerjee, Sw.; Bannoura, A. A. E.; Barak, L.; Barberio, E. L.; Barberis, D.; Barbero, M.; Barillari, T.; Barisits, M.-S.; Barkeloo, J. T.; Barklow, T.; Barlow, N.; Barnea, R.; Barnes, S. L.; Barnett, B. M.; Barnett, R. M.; Barnovska-Blenessy, Z.; Baroncelli, A.; Barone, G.; Barr, A. J.; Barranco Navarro, L.; Barreiro, F.; Barreiro Guimarães da Costa, J.; Bartoldus, R.; Barton, A. E.; Bartos, P.; Basalaev, A.; Bassalat, A.; Bates, R. L.; Batista, S. J.; Batley, J. R.; Battaglia, M.; Bauce, M.; Bauer, F.; Bauer, K. T.; Bawa, H. S.; Beacham, J. B.; Beattie, M. D.; Beau, T.; Beauchemin, P. H.; Bechtle, P.; Beck, H. P.; Beck, H. C.; Becker, K.; Becker, M.; Becot, C.; Beddall, A. J.; Beddall, A.; Bednyakov, V. A.; Bedognetti, M.; Bee, C. P.; Beermann, T. A.; Begalli, M.; Begel, M.; Behera, A.; Behr, J. K.; Bell, A. S.; Bella, G.; Bellagamba, L.; Bellerive, A.; Bellomo, M.; Belotskiy, K.; Belyaev, N. L.; Benary, O.; Benchekroun, D.; Bender, M.; Benekos, N.; Benhammou, Y.; Benhar Noccioli, E.; Benitez, J.; Benjamin, D. P.; Benoit, M.; Bensinger, J. R.; Bentvelsen, S.; Beresford, L.; Beretta, M.; Berge, D.; Bergeaas Kuutmann, E.; Berger, N.; Bergsten, L. J.; Beringer, J.; Berlendis, S.; Bernard, N. R.; Bernardi, G.; Bernius, C.; Bernlochner, F. U.; Berry, T.; Berta, P.; Bertella, C.; Bertoli, G.; Bertram, I. A.; Bertsche, C.; Besjes, G. J.; Bessidskaia Bylund, O.; Bessner, M.; Besson, N.; Bethani, A.; Bethke, S.; Betti, A.; Bevan, A. J.; Beyer, J.; Bianchi, R. M.; Biebel, O.; Biedermann, D.; Bielski, R.; Bierwagen, K.; Biesuz, N. V.; Biglietti, M.; Billoud, T. R. V.; Bindi, M.; Bingul, A.; Bini, C.; Biondi, S.; Bisanz, T.; Bittrich, C.; Bjergaard, D. M.; Black, J. E.; Black, K. M.; Blair, R. E.; Blazek, T.; Bloch, I.; Blocker, C.; Blue, A.; Blumenschein, U.; Blunier, Dr.; Bobbink, G. J.; Bobrovnikov, V. S.; Bocchetta, S. S.; Bocci, A.; Bock, C.; Boerner, D.; Bogavac, D.; Bogdanchikov, A. G.; Bohm, C.; Boisvert, V.; Bokan, P.; Bold, T.; Boldyrev, A. S.; Bolz, A. E.; Bomben, M.; Bona, M.; Bonilla, J. S.; Boonekamp, M.; Borisov, A.; Borissov, G.; Bortfeldt, J.; Bortoletto, D.; Bortolotto, V.; Boscherini, D.; Bosman, M.; Bossio Sola, J. D.; Boudreau, J.; Bouhova-Thacker, E. V.; Boumediene, D.; Bourdarios, C.; Boutle, S. K.; Boveia, A.; Boyd, J.; Boyko, I. R.; Bozson, A. J.; Bracinik, J.; Brandt, A.; Brandt, G.; Brandt, O.; Braren, F.; Bratzler, U.; Brau, B.; Brau, J. E.; Breaden Madden, W. D.; Brendlinger, K.; Brennan, A. J.; Brenner, L.; Brenner, R.; Bressler, S.; Briglin, D. L.; Bristow, T. M.; Britton, D.; Britzger, D.; Brock, I.; Brock, R.; Brooijmans, G.; Brooks, T.; Brooks, W. K.; Brost, E.; Broughton, J. H.; Bruckman de Renstrom, P. A.; Bruncko, D.; Bruni, A.; Bruni, G.; Bruni, L. S.; Bruno, S.; Brunt, Bh; Bruschi, M.; Bruscino, N.; Bryant, P.; Bryngemark, L.; Buanes, T.; Buat, Q.; Buchholz, P.; Buckley, A. G.; Budagov, I. A.; Buehrer, F.; Bugge, M. K.; Bulekov, O.; Bullock, D.; Burch, T. J.; Burdin, S.; Burgard, C. D.; Burger, A. M.; Burghgrave, B.; Burka, K.; Burke, S.; Burmeister, I.; Burr, J. T. P.; Büscher, D.; Büscher, V.; Buschmann, E.; Bussey, P.; Butler, J. M.; Buttar, C. M.; Butterworth, J. M.; Butti, P.; Buttinger, W.; Buzatu, A.; Buzykaev, A. R.; Cabras, G.; Cabrera Urbán, S.; Caforio, D.; Cai, H.; Cairo, V. M. M.; Cakir, O.; Calace, N.; Calafiura, P.; Calandri, A.; Calderini, G.; Calfayan, P.; Callea, G.; Caloba, L. P.; Calvente Lopez, S.; Calvet, D.; Calvet, S.; Calvet, T. P.; Camacho Toro, R.; Camarda, S.; Camarri, P.; Cameron, D.; Caminal Armadans, R.; Camincher, C.; Campana, S.; Campanelli, M.; Camplani, A.; Campoverde, A.; Canale, V.; Cano Bret, M.; Cantero, J.; Cao, T.; Capeans Garrido, M. D. M.; Caprini, I.; Caprini, M.; Capua, M.; Carbone, R. M.; Cardarelli, R.; Cardillo, F.; Carli, I.; Carli, T.; Carlino, G.; Carlson, B. T.; Carminati, L.; Carney, R. M. D.; Caron, S.; Carquin, E.; Carrá, S.; Carrillo-Montoya, G. D.; Casadei, D.; Casado, M. P.; Casha, A. F.; Casolino, M.; Casper, D. W.; Castelijn, R.; Castillo Gimenez, V.; Castro, N. F.; Catinaccio, A.; Catmore, J. R.; Cattai, A.; Caudron, J.; Cavaliere, V.; Cavallaro, E.; Cavalli, D.; Cavalli-Sforza, M.; Cavasinni, V.; Celebi, E.; Ceradini, F.; Cerda Alberich, L.; Cerqueira, A. S.; Cerri, A.; Cerrito, L.; Cerutti, F.; Cervelli, A.; Cetin, S. A.; Chafaq, A.; Chakraborty, D.; Chan, S. K.; Chan, W. S.; Chan, Y. L.; Chang, P.; Chapman, J. D.; Charlton, D. G.; Chau, C. C.; Chavez Barajas, C. A.; Che, S.; Chegwidden, A.; Chekanov, S.; Chekulaev, S. V.; Chelkov, G. A.; Chelstowska, M. A.; Chen, C.; Chen, C.; Chen, H.; Chen, J.; Chen, J.; Chen, S.; Chen, S.; Chen, X.; Chen, Y.; Cheng, H. C.; Cheng, H. J.; Cheplakov, A.; Cheremushkina, E.; Cherkaoui El Moursli, R.; Cheu, E.; Cheung, K.; Chevalier, L.; Chiarella, V.; Chiarelli, G.; Chiodini, G.; Chisholm, A. S.; Chitan, A.; Chiu, Y. H.; Chizhov, M. V.; Choi, K.; Chomont, A. R.; Chouridou, S.; Chow, Y. S.; Christodoulou, V.; Chu, M. C.; Chudoba, J.; Chuinard, A. J.; Chwastowski, J. J.; Chytka, L.; Cinca, D.; Cindro, V.; Cioarǎ, I. A.; Ciocio, A.; Cirotto, F.; Citron, Z. H.; Citterio, M.; Clark, A.; Clark, M. R.; Clark, P. J.; Clarke, R. N.; Clement, C.; Coadou, Y.; Cobal, M.; Coccaro, A.; Cochran, J.; Colasurdo, L.; Cole, B.; Colijn, A. P.; Collot, J.; Conde Muiño, P.; Coniavitis, E.; Connell, S. H.; Connelly, I. A.; Constantinescu, S.; Conti, G.; Conventi, F.; Cooper-Sarkar, A. M.; Cormier, F.; Cormier, K. J. R.; Corradi, M.; Corrigan, E. E.; Corriveau, F.; Cortes-Gonzalez, A.; Costa, M. J.; Costanzo, D.; Cottin, G.; Cowan, G.; Cox, B. E.; Cranmer, K.; Crawley, S. J.; Creager, R. A.; Cree, G.; Crépé-Renaudin, S.; Crescioli, F.; Cristinziani, M.; Croft, V.; Crosetti, G.; Cueto, A.; Cuhadar Donszelmann, T.; Cukierman, A. R.; Cummings, J.; Curatolo, M.; Cúth, J.; Czekierda, S.; Czodrowski, P.; D'Amen, G.; D'Auria, S.; D'Eramo, L.; D'Onofrio, M.; da Cunha Sargedas de Sousa, M. J.; da Via, C.; Dabrowski, W.; Dado, T.; Dahbi, S.; Dai, T.; Dale, O.; Dallaire, F.; Dallapiccola, C.; Dam, M.; Dandoy, J. R.; Daneri, M. F.; Dang, N. P.; Dann, N. S.; Danninger, M.; Dano Hoffmann, M.; Dao, V.; Darbo, G.; Darmora, S.; Dattagupta, A.; Daubney, T.; Davey, W.; David, C.; Davidek, T.; Davis, D. R.; Davison, P.; Dawe, E.; Dawson, I.; de, K.; de Asmundis, R.; de Benedetti, A.; de Castro, S.; de Cecco, S.; de Groot, N.; de Jong, P.; de la Torre, H.; de Lorenzi, F.; de Maria, A.; de Pedis, D.; de Salvo, A.; de Sanctis, U.; de Santo, A.; de Vasconcelos Corga, K.; de Vivie de Regie, J. B.; Debenedetti, C.; Dedovich, D. V.; Dehghanian, N.; Deigaard, I.; Del Gaudio, M.; Del Peso, J.; Delgove, D.; Deliot, F.; Delitzsch, C. M.; Dell'Acqua, A.; Dell'Asta, L.; Della Pietra, M.; Della Volpe, D.; Delmastro, M.; Delporte, C.; Delsart, P. A.; Demarco, D. A.; Demers, S.; Demichev, M.; Denisov, S. P.; Denysiuk, D.; Derendarz, D.; Derkaoui, J. E.; Derue, F.; Dervan, P.; Desch, K.; Deterre, C.; Dette, K.; Devesa, M. R.; Deviveiros, P. O.; Dewhurst, A.; Dhaliwal, S.; di Bello, F. A.; di Ciaccio, A.; di Ciaccio, L.; di Clemente, W. K.; di Donato, C.; di Girolamo, A.; di Micco, B.; di Nardo, R.; di Petrillo, K. F.; di Simone, A.; di Sipio, R.; di Valentino, D.; Diaconu, C.; Diamond, M.; Dias, F. A.; Diaz, M. A.; Dickinson, J.; Diehl, E. B.; Dietrich, J.; Díez Cornell, S.; Dimitrievska, A.; Dingfelder, J.; Dita, P.; Dita, S.; Dittus, F.; Djama, F.; Djobava, T.; Djuvsland, J. I.; Do Vale, M. A. B.; Dobre, M.; Dodsworth, D.; Doglioni, C.; Dolejsi, J.; Dolezal, Z.; Donadelli, M.; Donati, S.; Donini, J.; Dopke, J.; Doria, A.; Dova, M. T.; Doyle, A. T.; Drechsler, E.; Dreyer, E.; Dris, M.; Du, Y.; Duarte-Campderros, J.; Dubinin, F.; Dubreuil, A.; Duchovni, E.; Duckeck, G.; Ducourthial, A.; Ducu, O. A.; Duda, D.; Dudarev, A.; Dudder, A. Chr.; Duffield, E. M.; Duflot, L.; Dührssen, M.; Dulsen, C.; Dumancic, M.; Dumitriu, A. E.; Duncan, A. K.; Dunford, M.; Duperrin, A.; Duran Yildiz, H.; Düren, M.; Durglishvili, A.; Duschinger, D.; Dutta, B.; Duvnjak, D.; Dyndal, M.; Dziedzic, B. S.; Eckardt, C.; Ecker, K. M.; Edgar, R. C.; Eifert, T.; Eigen, G.; Einsweiler, K.; Ekelof, T.; El Kacimi, M.; El Kosseifi, R.; Ellajosyula, V.; Ellert, M.; Ellinghaus, F.; Elliot, A. A.; Ellis, N.; Elmsheuser, J.; Elsing, M.; Emeliyanov, D.; Enari, Y.; Ennis, J. S.; Epland, M. B.; Erdmann, J.; Ereditato, A.; Errede, S.; Escalier, M.; Escobar, C.; Esposito, B.; Estrada Pastor, O.; Etienvre, A. I.; Etzion, E.; Evans, H.; Ezhilov, A.; Ezzi, M.; Fabbri, F.; Fabbri, L.; Fabiani, V.; Facini, G.; Fakhrutdinov, R. M.; Falciano, S.; Faltova, J.; Fang, Y.; Fanti, M.; Farbin, A.; Farilla, A.; Farina, E. M.; Farooque, T.; Farrell, S.; Farrington, S. M.; Farthouat, P.; Fassi, F.; Fassnacht, P.; Fassouliotis, D.; Faucci Giannelli, M.; Favareto, A.; Fawcett, W. J.; Fayard, L.; Fedin, O. L.; Fedorko, W.; Feickert, M.; Feigl, S.; Feligioni, L.; Feng, C.; Feng, E. J.; Feng, M.; Fenton, M. J.; Fenyuk, A. B.; Feremenga, L.; Fernandez Martinez, P.; Ferrando, J.; Ferrari, A.; Ferrari, P.; Ferrari, R.; Ferreira de Lima, D. E.; Ferrer, A.; Ferrere, D.; Ferretti, C.; Fiedler, F.; Filipčič, A.; Filthaut, F.; Fincke-Keeler, M.; Finelli, K. D.; Fiolhais, M. C. N.; Fiorini, L.; Fischer, C.; Fischer, J.; Fisher, W. C.; Flaschel, N.; Fleck, I.; Fleischmann, P.; Fletcher, R. R. M.; Flick, T.; Flierl, B. M.; Flores, L. M.; Flores Castillo, L. R.; Fomin, N.; Forcolin, G. T.; Formica, A.; Förster, F. A.; Forti, A.; Foster, A. G.; Fournier, D.; Fox, H.; Fracchia, S.; Francavilla, P.; Franchini, M.; Franchino, S.; Francis, D.; Franconi, L.; Franklin, M.; Frate, M.; Fraternali, M.; Freeborn, D.; Fressard-Batraneanu, S. M.; Freund, B.; Freund, W. S.; Froidevaux, D.; Frost, J. A.; Fukunaga, C.; Fusayasu, T.; Fuster, J.; Gabizon, O.; Gabrielli, A.; Gabrielli, A.; Gach, G. P.; Gadatsch, S.; Gadomski, S.; Gagliardi, G.; Gagnon, L. G.; Galea, C.; Galhardo, B.; Gallas, E. J.; Gallop, B. J.; Gallus, P.; Galster, G.; Gan, K. K.; Ganguly, S.; Gao, Y.; Gao, Y. S.; Garay Walls, F. M.; García, C.; García Navarro, J. E.; García Pascual, J. A.; Garcia-Sciveres, M.; Gardner, R. W.; Garelli, N.; Garonne, V.; Gasnikova, K.; Gaudiello, A.; Gaudio, G.; Gavrilenko, I. L.; Gay, C.; Gaycken, G.; Gazis, E. N.; Gee, C. N. P.; Geisen, J.; Geisen, M.; Geisler, M. P.; Gellerstedt, K.; Gemme, C.; Genest, M. H.; Geng, C.; Gentile, S.; Gentsos, C.; George, S.; Gerbaudo, D.; Geßner, G.; Ghasemi, S.; Ghneimat, M.; Giacobbe, B.; Giagu, S.; Giangiacomi, N.; Giannetti, P.; Gibson, S. M.; Gignac, M.; Gilchriese, M.; Gillberg, D.; Gilles, G.; Gingrich, D. M.; Giordani, M. P.; Giorgi, F. M.; Giraud, P. F.; Giromini, P.; Giugliarelli, G.; Giugni, D.; Giuli, F.; Giulini, M.; Gkaitatzis, S.; Gkialas, I.; Gkougkousis, E. L.; Gkountoumis, P.; Gladilin, L. K.; Glasman, C.; Glatzer, J.; Glaysher, P. C. F.; Glazov, A.; Goblirsch-Kolb, M.; Godlewski, J.; Goldfarb, S.; Golling, T.; Golubkov, D.; Gomes, A.; Gonçalo, R.; Goncalves Gama, R.; Gonella, G.; Gonella, L.; Gongadze, A.; Gonnella, F.; Gonski, J. L.; González de La Hoz, S.; Gonzalez-Sevilla, S.; Goossens, L.; Gorbounov, P. A.; Gordon, H. A.; Gorini, B.; Gorini, E.; Gorišek, A.; Goshaw, A. T.; Gössling, C.; Gostkin, M. I.; Gottardo, C. A.; Goudet, C. R.; Goujdami, D.; Goussiou, A. G.; Govender, N.; Goy, C.; Gozani, E.; Grabowska-Bold, I.; Gradin, P. O. J.; Graham, E. C.; Gramling, J.; Gramstad, E.; Grancagnolo, S.; Gratchev, V.; Gravila, P. M.; Gray, C.; Gray, H. M.; Greenwood, Z. D.; Grefe, C.; Gregersen, K.; Gregor, I. M.; Grenier, P.; Grevtsov, K.; Griffiths, J.; Grillo, A. A.; Grimm, K.; Grinstein, S.; Gris, Ph.; Grivaz, J.-F.; Groh, S.; Gross, E.; Grosse-Knetter, J.; Grossi, G. C.; Grout, Z. J.; Grummer, A.; Guan, L.; Guan, W.; Guenther, J.; Guerguichon, A.; Guescini, F.; Guest, D.; Gueta, O.; Gugel, R.; Gui, B.; Guillemin, T.; Guindon, S.; Gul, U.; Gumpert, C.; Guo, J.; Guo, W.; Guo, Y.; Gupta, R.; Gurbuz, S.; Gustavino, G.; Gutelman, B. J.; Gutierrez, P.; Gutierrez Ortiz, N. G.; Gutschow, C.; Guyot, C.; Guzik, M. P.; Gwenlan, C.; Gwilliam, C. B.; Haas, A.; Haber, C.; Hadavand, H. K.; Haddad, N.; Hadef, A.; Hageböck, S.; Hagihara, M.; Hakobyan, H.; Haleem, M.; Haley, J.; Halladjian, G.; Hallewell, G. D.; Hamacher, K.; Hamal, P.; Hamano, K.; Hamilton, A.; Hamity, G. N.; Han, K.; Han, L.; Han, S.; Hanagaki, K.; Hance, M.; Handl, D. M.; Haney, B.; Hankache, R.; Hanke, P.; Hansen, E.; Hansen, J. B.; Hansen, J. D.; Hansen, M. C.; Hansen, P. H.; Hara, K.; Hard, A. S.; Harenberg, T.; Harkusha, S.; Harrison, P. F.; Hartmann, N. M.; Hasegawa, Y.; Hasib, A.; Hassani, S.; Haug, S.; Hauser, R.; Hauswald, L.; Havener, L. B.; Havranek, M.; Hawkes, C. M.; Hawkings, R. J.; Hayden, D.; Hays, C. P.; Hays, J. M.; Hayward, H. S.; Haywood, S. J.; Heck, T.; Hedberg, V.; Heelan, L.; Heer, S.; Heidegger, K. K.; Heim, S.; Heim, T.; Heinemann, B.; Heinrich, J. J.; Heinrich, L.; Heinz, C.; Hejbal, J.; Helary, L.; Held, A.; Hellman, S.; Helsens, C.; Henderson, R. C. W.; Heng, Y.; Henkelmann, S.; Henriques Correia, A. M.; Herbert, G. H.; Herde, H.; Herget, V.; Hernández Jiménez, Y.; Herr, H.; Herten, G.; Hertenberger, R.; Hervas, L.; Herwig, T. C.; Hesketh, G. G.; Hessey, N. P.; Hetherly, J. W.; Higashino, S.; Higón-Rodriguez, E.; Hildebrand, K.; Hill, E.; Hill, J. C.; Hiller, K. H.; Hillier, S. J.; Hils, M.; Hinchliffe, I.; Hirose, M.; Hirschbuehl, D.; Hiti, B.; Hladik, O.; Hlaluku, D. R.; Hoad, X.; Hobbs, J.; Hod, N.; Hodgkinson, M. C.; Hoecker, A.; Hoeferkamp, M. R.; Hoenig, F.; Hohn, D.; Hohov, D.; Holmes, T. R.; Holzbock, M.; Homann, M.; Honda, S.; Honda, T.; Hong, T. M.; Hooberman, B. H.; Hopkins, W. H.; Horii, Y.; Horton, A. J.; Horyn, L. A.; Hostachy, J.-Y.; Hostiuc, A.; Hou, S.; Hoummada, A.; Howarth, J.; Hoya, J.; Hrabovsky, M.; Hrdinka, J.; Hristova, I.; Hrivnac, J.; Hryn'ova, T.; Hrynevich, A.; Hsu, P. J.; Hsu, S.-C.; Hu, Q.; Hu, S.; Huang, Y.; Hubacek, Z.; Hubaut, F.; Huegging, F.; Huffman, T. B.; Hughes, E. W.; Huhtinen, M.; Hunter, R. F. H.; Huo, P.; Hupe, A. M.; Huseynov, N.; Huston, J.; Huth, J.; Hyneman, R.; Iacobucci, G.; Iakovidis, G.; Ibragimov, I.; Iconomidou-Fayard, L.; Idrissi, Z.; Iengo, P.; Igonkina, O.; Iguchi, R.; Iizawa, T.; Ikegami, Y.; Ikeno, M.; Iliadis, D.; Ilic, N.; Iltzsche, F.; Introzzi, G.; Iodice, M.; Iordanidou, K.; Ippolito, V.; Isacson, M. F.; Ishijima, N.; Ishino, M.; Ishitsuka, M.; Issever, C.; Istin, S.; Ito, F.; Iturbe Ponce, J. M.; Iuppa, R.; Iwasaki, H.; Izen, J. M.; Izzo, V.; Jabbar, S.; Jackson, P.; Jacobs, R. M.; Jain, V.; Jakel, G.; Jakobi, K. B.; Jakobs, K.; Jakobsen, S.; Jakoubek, T.; Jamin, D. O.; Jana, D. K.; Jansky, R.; Janssen, J.; Janus, M.; Janus, P. A.; Jarlskog, G.; Javadov, N.; Javå¯Rek, T.; Javurkova, M.; Jeanneau, F.; Jeanty, L.; Jejelava, J.; Jelinskas, A.; Jenni, P.; Jeske, C.; Jézéquel, S.; Ji, H.; Jia, J.; Jiang, H.; Jiang, Y.; Jiang, Z.; Jiggins, S.; Jimenez Pena, J.; Jin, S.; Jinaru, A.; Jinnouchi, O.; Jivan, H.; Johansson, P.; Johns, K. A.; Johnson, C. A.; Johnson, W. J.; Jon-And, K.; Jones, R. W. L.; Jones, S. D.; Jones, S.; Jones, T. J.; Jongmanns, J.; Jorge, P. M.; Jovicevic, J.; Ju, X.; Junggeburth, J. J.; Juste Rozas, A.; Kaczmarska, A.; Kado, M.; Kagan, H.; Kagan, M.; Kahn, S. J.; Kaji, T.; Kajomovitz, E.; Kalderon, C. W.; Kaluza, A.; Kama, S.; Kamenshchikov, A.; Kanjir, L.; Kano, Y.; Kantserov, V. A.; Kanzaki, J.; Kaplan, B.; Kaplan, L. S.; Kar, D.; Karakostas, K.; Karastathis, N.; Kareem, M. J.; Karentzos, E.; Karpov, S. N.; Karpova, Z. M.; Kartvelishvili, V.; Karyukhin, A. N.; Kasahara, K.; Kashif, L.; Kass, R. D.; Kastanas, A.; Kataoka, Y.; Kato, C.; Katre, A.; Katzy, J.; Kawade, K.; Kawagoe, K.; Kawamoto, T.; Kawamura, G.; Kay, E. F.; Kazanin, V. F.; Keeler, R.; Kehoe, R.; Keller, J. S.; Kellermann, E.; Kempster, J. J.; Kendrick, J.; Keoshkerian, H.; Kepka, O.; Kerševan, B. P.; Kersten, S.; Keyes, R. A.; Khader, M.; Khalil-Zada, F.; Khanov, A.; Kharlamov, A. G.; Kharlamova, T.; Khodinov, A.; Khoo, T. J.; Khovanskiy, V.; Khramov, E.; Khubua, J.; Kido, S.; Kiehn, M.; Kilby, C. R.; Kim, H. Y.; Kim, S. H.; Kim, Y. K.; Kimura, N.; Kind, O. M.; King, B. T.; Kirchmeier, D.; Kirk, J.; Kiryunin, A. E.; Kishimoto, T.; Kisielewska, D.; Kitali, V.; Kivernyk, O.; Kladiva, E.; Klapdor-Kleingrothaus, T.; Klein, M. H.; Klein, M.; Klein, U.; Kleinknecht, K.; Klimek, P.; Klimentov, A.; Klingenberg, R.; Klingl, T.; Klioutchnikova, T.; Klitzner, F. F.; Kluge, E.-E.; Kluit, P.; Kluth, S.; Kneringer, E.; Knoops, E. B. F. G.; Knue, A.; Kobayashi, A.; Kobayashi, D.; Kobayashi, T.; Kobel, M.; Kocian, M.; Kodys, P.; Koffas, T.; Koffeman, E.; Köhler, N. M.; Koi, T.; Kolb, M.; Koletsou, I.; Kondo, T.; Kondrashova, N.; Köneke, K.; König, A. C.; Kono, T.; Konoplich, R.; Konstantinidis, N.; Konya, B.; Kopeliansky, R.; Koperny, S.; Korcyl, K.; Kordas, K.; Korn, A.; Korolkov, I.; Korolkova, E. V.; Kortner, O.; Kortner, S.; Kosek, T.; Kostyukhin, V. V.; Kotwal, A.; Koulouris, A.; Kourkoumeli-Charalampidi, A.; Kourkoumelis, C.; Kourlitis, E.; Kouskoura, V.; Kowalewska, A. B.; Kowalewski, R.; Kowalski, T. Z.; Kozakai, C.; Kozanecki, W.; Kozhin, A. S.; Kramarenko, V. A.; Kramberger, G.; Krasnopevtsev, D.; Krasny, M. W.; Krasznahorkay, A.; Krauss, D.; Kremer, J. A.; Kretzschmar, J.; Kreutzfeldt, K.; Krieger, P.; Krizka, K.; Kroeninger, K.; Kroha, H.; Kroll, J.; Kroll, J.; Kroseberg, J.; Krstic, J.; Kruchonak, U.; Krüger, H.; Krumnack, N.; Kruse, M. C.; Kubota, T.; Kuday, S.; Kuechler, J. T.; Kuehn, S.; Kugel, A.; Kuger, F.; Kuhl, T.; Kukhtin, V.; Kukla, R.; Kulchitsky, Y.; Kuleshov, S.; Kulinich, Y. P.; Kuna, M.; Kunigo, T.; Kupco, A.; Kupfer, T.; Kuprash, O.; Kurashige, H.; Kurchaninov, L. L.; Kurochkin, Y. A.; Kurth, M. G.; Kuwertz, E. S.; Kuze, M.; Kvita, J.; Kwan, T.; La Rosa, A.; La Rosa Navarro, J. L.; La Rotonda, L.; La Ruffa, F.; Lacasta, C.; Lacava, F.; Lacey, J.; Lack, D. P. J.; Lacker, H.; Lacour, D.; Ladygin, E.; Lafaye, R.; Laforge, B.; Lai, S.; Lammers, S.; Lampl, W.; Lançon, E.; Landgraf, U.; Landon, M. P. J.; Lanfermann, M. C.; Lang, V. S.; Lange, J. C.; Langenberg, R. J.; Lankford, A. J.; Lanni, F.; Lantzsch, K.; Lanza, A.; Lapertosa, A.; Laplace, S.; Laporte, J. F.; Lari, T.; Lasagni Manghi, F.; Lassnig, M.; Lau, T. S.; Laudrain, A.; Law, A. T.; Laycock, P.; Lazzaroni, M.; Le, B.; Le Dortz, O.; Le Guirriec, E.; Le Quilleuc, E. P.; Leblanc, M.; Lecompte, T.; Ledroit-Guillon, F.; Lee, C. A.; Lee, G. R.; Lee, S. C.; Lee, L.; Lefebvre, B.; Lefebvre, M.; Legger, F.; Leggett, C.; Lehmann Miotto, G.; Leight, W. A.; Leisos, A.; Leite, M. A. L.; Leitner, R.; Lellouch, D.; Lemmer, B.; Leney, K. J. C.; Lenz, T.; Lenzi, B.; Leone, R.; Leone, S.; Leonidopoulos, C.; Lerner, G.; Leroy, C.; Les, R.; Lesage, A. A. J.; Lester, C. G.; Levchenko, M.; Levêque, J.; Levin, D.; Levinson, L. J.; Levy, M.; Lewis, D.; Li, B.; Li, C.-Q.; Li, H.; Li, L.; Li, Q.; Li, Q.; Li, S.; Li, X.; Li, Y.; Liang, Z.; Liberti, B.; Liblong, A.; Lie, K.; Limosani, A.; Lin, C. Y.; Lin, K.; Lin, S. C.; Lin, T. H.; Linck, R. A.; Lindquist, B. E.; Lionti, A. E.; Lipeles, E.; Lipniacka, A.; Lisovyi, M.; Liss, T. M.; Lister, A.; Litke, A. M.; Liu, B.; Liu, H.; Liu, H.; Liu, J. K. K.; Liu, J. B.; Liu, K.; Liu, M.; Liu, P.; Liu, Y. L.; Liu, Y.; Livan, M.; Lleres, A.; Llorente Merino, J.; Lloyd, S. L.; Lo, C. Y.; Lo Sterzo, F.; Lobodzinska, E. M.; Loch, P.; Loebinger, F. K.; Loesle, A.; Loew, K. M.; Lohse, T.; Lohwasser, K.; Lokajicek, M.; Long, B. A.; Long, J. D.; Long, R. E.; Longo, L.; Looper, K. A.; Lopez, J. A.; Lopez Paz, I.; Lopez Solis, A.; Lorenz, J.; Lorenzo Martinez, N.; Losada, M.; Lösel, P. J.; Lou, X.; Lounis, A.; Love, J.; Love, P. A.; Lu, H.; Lu, N.; Lu, Y. J.; Lubatti, H. J.; Luci, C.; Lucotte, A.; Luedtke, C.; Luehring, F.; Lukas, W.; Luminari, L.; Lund-Jensen, B.; Lutz, M. S.; Luzi, P. M.; Lynn, D.; Lysak, R.; Lytken, E.; Lyu, F.; Lyubushkin, V.; Ma, H.; Ma, L. L.; Ma, Y.; Maccarrone, G.; Macchiolo, A.; MacDonald, C. M.; Maček, B.; Machado Miguens, J.; Madaffari, D.; Madar, R.; Mader, W. F.; Madsen, A.; Madysa, N.; Maeda, J.; Maeland, S.; Maeno, T.; Maevskiy, A. S.; Magerl, V.; Maidantchik, C.; Maier, T.; Maio, A.; Majersky, O.; Majewski, S.; Makida, Y.; Makovec, N.; Malaescu, B.; Malecki, Pa.; Maleev, V. P.; Malek, F.; Mallik, U.; Malon, D.; Malone, C.; Maltezos, S.; Malyukov, S.; Mamuzic, J.; Mancini, G.; Mandić, I.; Maneira, J.; Manhaes de Andrade Filho, L.; Manjarres Ramos, J.; Mankinen, K. H.; Mann, A.; Manousos, A.; Mansoulie, B.; Mansour, J. D.; Mantifel, R.; Mantoani, M.; Manzoni, S.; Marceca, G.; March, L.; Marchese, L.; Marchiori, G.; Marcisovsky, M.; Marin Tobon, C. A.; Marjanovic, M.; Marley, D. E.; Marroquim, F.; Marshall, Z.; Martensson, M. U. F.; Marti-Garcia, S.; Martin, C. B.; Martin, T. A.; Martin, V. J.; Martin Dit Latour, B.; Martinez, M.; Martinez Outschoorn, V. I.; Martin-Haugh, S.; Martoiu, V. S.; Martyniuk, A. C.; Marzin, A.; Masetti, L.; Mashimo, T.; Mashinistov, R.; Masik, J.; Maslennikov, A. L.; Mason, L. H.; Massa, L.; Mastrandrea, P.; Mastroberardino, A.; Masubuchi, T.; Mättig, P.; Maurer, J.; Maxfield, S. J.; Maximov, D. A.; Mazini, R.; Maznas, I.; Mazza, S. M.; Mc Fadden, N. C.; Mc Goldrick, G.; Mc Kee, S. P.; McCarn, A.; McCarthy, T. G.; McClymont, L. I.; McDonald, E. F.; McFayden, J. A.; McHedlidze, G.; McKay, M. A.; McMahon, S. J.; McNamara, P. C.; McNicol, C. J.; McPherson, R. A.; Meadows, Z. A.; Meehan, S.; Megy, T. J.; Mehlhase, S.; Mehta, A.; Meideck, T.; Meier, K.; Meirose, B.; Melini, D.; Mellado Garcia, B. R.; Mellenthin, J. D.; Melo, M.; Meloni, F.; Melzer, A.; Menary, S. B.; Meng, L.; Meng, X. T.; Mengarelli, A.; Menke, S.; Meoni, E.; Mergelmeyer, S.; Merlassino, C.; Mermod, P.; Merola, L.; Meroni, C.; Merritt, F. S.; Messina, A.; Metcalfe, J.; Mete, A. S.; Meyer, C.; Meyer, J.-P.; Meyer, J.; Meyer Zu Theenhausen, H.; Miano, F.; Middleton, R. P.; Miglioranzi, S.; Mijović, L.; Mikenberg, G.; Mikestikova, M.; Mikuž, M.; Milesi, M.; Milic, A.; Millar, D. A.; Miller, D. W.; Milov, A.; Milstead, D. A.; Minaenko, A. A.; Minashvili, I. A.; Mincer, A. I.; Mindur, B.; Mineev, M.; Minegishi, Y.; Ming, Y.; Mir, L. M.; Mirto, A.; Mistry, K. P.; Mitani, T.; Mitrevski, J.; Mitsou, V. A.; Miucci, A.; Miyagawa, P. S.; Mizukami, A.; Mjörnmark, J. U.; Mkrtchyan, T.; Mlynarikova, M.; Moa, T.; Mochizuki, K.; Mogg, P.; Mohapatra, S.; Molander, S.; Moles-Valls, R.; Mondragon, M. C.; Mönig, K.; Monk, J.; Monnier, E.; Montalbano, A.; Montejo Berlingen, J.; Monticelli, F.; Monzani, S.; Moore, R. W.; Morange, N.; Moreno, D.; Moreno Llácer, M.; Morettini, P.; Morgenstern, M.; Morgenstern, S.; Mori, D.; Mori, T.; Morii, M.; Morinaga, M.; Morisbak, V.; Morley, A. K.; Mornacchi, G.; Morris, J. D.; Morvaj, L.; Moschovakos, P.; Mosidze, M.; Moss, H. J.; Moss, J.; Motohashi, K.; Mount, R.; Mountricha, E.; Moyse, E. J. W.; Muanza, S.; Mueller, F.; Mueller, J.; Mueller, R. S. P.; Muenstermann, D.; Mullen, P.; Mullier, G. A.; Munoz Sanchez, F. J.; Murin, P.; Murray, W. J.; Murrone, A.; Muškinja, M.; Mwewa, C.; Myagkov, A. G.; Myers, J.; Myska, M.; Nachman, B. P.; Nackenhorst, O.; Nagai, K.; Nagai, R.; Nagano, K.; Nagasaka, Y.; Nagata, K.; Nagel, M.; Nagy, E.; Nairz, A. M.; Nakahama, Y.; Nakamura, K.; Nakamura, T.; Nakano, I.; Naranjo Garcia, R. F.; Narayan, R.; Narrias Villar, D. I.; Naryshkin, I.; Naumann, T.; Navarro, G.; Nayyar, R.; Neal, H. A.; Nechaeva, P. Yu.; Neep, T. J.; Negri, A.; Negrini, M.; Nektarijevic, S.; Nellist, C.; Nelson, M. E.; Nemecek, S.; Nemethy, P.; Nessi, M.; Neubauer, M. S.; Neumann, M.; Newman, P. R.; Ng, T. Y.; Ng, Y. S.; Nguyen Manh, T.; Nickerson, R. B.; Nicolaidou, R.; Nielsen, J.; Nikiforou, N.; Nikolaenko, V.; Nikolic-Audit, I.; Nikolopoulos, K.; Nilsson, P.; Ninomiya, Y.; Nisati, A.; Nishu, N.; Nisius, R.; Nitsche, I.; Nitta, T.; Nobe, T.; Noguchi, Y.; Nomachi, M.; Nomidis, I.; Nomura, M. A.; Nooney, T.; Nordberg, M.; Norjoharuddeen, N.; Novgorodova, O.; Novotny, R.; Nozaki, M.; Nozka, L.; Ntekas, K.; Nurse, E.; Nuti, F.; O'Connor, K.; O'Neil, D. C.; O'Rourke, A. A.; O'Shea, V.; Oakham, F. G.; Oberlack, H.; Obermann, T.; Ocariz, J.; Ochi, A.; Ochoa, I.; Ochoa-Ricoux, J. P.; Oda, S.; Odaka, S.; Oh, A.; Oh, S. H.; Ohm, C. C.; Ohman, H.; Oide, H.; Ojeda, M. L.; Okawa, H.; Okumura, Y.; Okuyama, T.; Olariu, A.; Oleiro Seabra, L. F.; Olivares Pino, S. A.; Oliveira Damazio, D.; Oliver, J. L.; Olsson, M. J. R.; Olszewski, A.; Olszowska, J.; Onofre, A.; Onogi, K.; Onyisi, P. U. E.; Oppen, H.; Oreglia, M. J.; Oren, Y.; Orestano, D.; Orgill, E. C.; Orlando, N.; Orr, R. S.; Osculati, B.; Ospanov, R.; Otero Y Garzon, G.; Otono, H.; Ouchrif, M.; Ould-Saada, F.; Ouraou, A.; Oussoren, K. P.; Ouyang, Q.; Owen, M.; Owen, R. E.; Ozcan, V. E.; Ozturk, N.; Pachal, K.; Pacheco Pages, A.; Pacheco Rodriguez, L.; Padilla Aranda, C.; Pagan Griso, S.; Paganini, M.; Paige, F.; Palacino, G.; Palazzo, S.; Palestini, S.; Palka, M.; Pallin, D.; Panagiotopoulou, E. St.; Panagoulias, I.; Pandini, C. E.; Panduro Vazquez, J. G.; Pani, P.; Pantea, D.; Paolozzi, L.; Papadopoulou, Th. D.; Papageorgiou, K.; Paramonov, A.; Paredes Hernandez, D.; Parida, B.; Parker, A. J.; Parker, M. A.; Parker, K. A.; Parodi, F.; Parsons, J. A.; Parzefall, U.; Pascuzzi, V. R.; Pasner, J. M.; Pasqualucci, E.; Passaggio, S.; Pastore, Fr.; Pataraia, S.; Pater, J. R.; Pauly, T.; Pearson, B.; Pedraza Lopez, S.; Pedro, R.; Peleganchuk, S. V.; Penc, O.; Peng, C.; Peng, H.; Penwell, J.; Peralva, B. S.; Perego, M. M.; Perepelitsa, D. V.; Peri, F.; Perini, L.; Pernegger, H.; Perrella, S.; Peshekhonov, V. D.; Peters, K.; Peters, R. F. Y.; Petersen, B. A.; Petersen, T. C.; Petit, E.; Petridis, A.; Petridou, C.; Petroff, P.; Petrolo, E.; Petrov, M.; Petrucci, F.; Pettersson, N. E.; Peyaud, A.; Pezoa, R.; Pham, T.; Phillips, F. H.; Phillips, P. W.; Piacquadio, G.; Pianori, E.; Picazio, A.; Pickering, M. A.; Piegaia, R.; Pilcher, J. E.; Pilkington, A. D.; Pinamonti, M.; Pinfold, J. L.; Pitt, M.; Pleier, M.-A.; Pleskot, V.; Plotnikova, E.; Pluth, D.; Podberezko, P.; Poettgen, R.; Poggi, R.; Poggioli, L.; Pogrebnyak, I.; Pohl, D.; Pokharel, I.; Polesello, G.; Poley, A.; Policicchio, A.; Polifka, R.; Polini, A.; Pollard, C. S.; Polychronakos, V.; Ponomarenko, D.; Pontecorvo, L.; Popeneciu, G. A.; Portillo Quintero, D. M.; Pospisil, S.; Potamianos, K.; Potrap, I. N.; Potter, C. J.; Potti, H.; Poulsen, T.; Poveda, J.; Pozo Astigarraga, M. E.; Pralavorio, P.; Prell, S.; Price, D.; Primavera, M.; Prince, S.; Proklova, N.; Prokofiev, K.; Prokoshin, F.; Protopopescu, S.; Proudfoot, J.; Przybycien, M.; Puri, A.; Puzo, P.; Qian, J.; Qin, Y.; Quadt, A.; Queitsch-Maitland, M.; Qureshi, A.; Radeka, V.; Radhakrishnan, S. K.; Rados, P.; Ragusa, F.; Rahal, G.; Raine, J. A.; Rajagopalan, S.; Rashid, T.; Raspopov, S.; Ratti, M. G.; Rauch, D. M.; Rauscher, F.; Rave, S.; Ravinovich, I.; Rawling, J. H.; Raymond, M.; Read, A. L.; Readioff, N. P.; Reale, M.; Rebuzzi, D. M.; Redelbach, A.; Redlinger, G.; Reece, R.; Reed, R. G.; Reeves, K.; Rehnisch, L.; Reichert, J.; Reiss, A.; Rembser, C.; Ren, H.; Rescigno, M.; Resconi, S.; Resseguie, E. D.; Rettie, S.; Reynolds, E.; Rezanova, O. L.; Reznicek, P.; Richter, R.; Richter, S.; Richter-Was, E.; Ricken, O.; Ridel, M.; Rieck, P.; Riegel, C. J.; Rifki, O.; Rijssenbeek, M.; Rimoldi, A.; Rimoldi, M.; Rinaldi, L.; Ripellino, G.; Ristić, B.; Ritsch, E.; Riu, I.; Rivera Vergara, J. C.; Rizatdinova, F.; Rizvi, E.; Rizzi, C.; Roberts, R. T.; Robertson, S. H.; Robichaud-Veronneau, A.; Robinson, D.; Robinson, J. E. M.; Robson, A.; Rocco, E.; Roda, C.; Rodina, Y.; Rodriguez Bosca, S.; Rodriguez Perez, A.; Rodriguez Rodriguez, D.; Rodríguez Vera, A. M.; Roe, S.; Rogan, C. S.; Røhne, O.; Röhrig, R.; Roloff, J.; Romaniouk, A.; Romano, M.; Romano Saez, S. M.; Romero Adam, E.; Rompotis, N.; Ronzani, M.; Roos, L.; Rosati, S.; Rosbach, K.; Rose, P.; Rosien, N.-A.; Rossi, E.; Rossi, L. P.; Rossini, L.; Rosten, J. H. N.; Rosten, R.; Rotaru, M.; Rothberg, J.; Rousseau, D.; Roy, D.; Rozanov, A.; Rozen, Y.; Ruan, X.; Rubbo, F.; Rühr, F.; Ruiz-Martinez, A.; Rurikova, Z.; Rusakovich, N. A.; Russell, H. L.; Rutherfoord, J. P.; Ruthmann, N.; Rüttinger, E. M.; Ryabov, Y. F.; Rybar, M.; Rybkin, G.; Ryu, S.; Ryzhov, A.; Rzehorz, G. F.; Saavedra, A. F.; Sabato, G.; Sacerdoti, S.; Sadrozinski, H. F.-W.; Sadykov, R.; Safai Tehrani, F.; Saha, P.; Sahinsoy, M.; Saimpert, M.; Saito, M.; Saito, T.; Sakamoto, H.; Salamanna, G.; Salazar Loyola, J. E.; Salek, D.; Sales de Bruin, P. H.; Salihagic, D.; Salnikov, A.; Salt, J.; Salvatore, D.; Salvatore, F.; Salvucci, A.; Salzburger, A.; Sammel, D.; Sampsonidis, D.; Sampsonidou, D.; Sánchez, J.; Sanchez Pineda, A.; Sandaker, H.; Sander, C. O.; Sandhoff, M.; Sandoval, C.; Sankey, D. P. C.; Sannino, M.; Sano, Y.; Sansoni, A.; Santoni, C.; Santos, H.; Santoyo Castillo, I.; Sapronov, A.; Saraiva, J. G.; Sasaki, O.; Sato, K.; Sauvan, E.; Savard, P.; Savic, N.; Sawada, R.; Sawyer, C.; Sawyer, L.; Sbarra, C.; Sbrizzi, A.; Scanlon, T.; Scannicchio, D. A.; Schaarschmidt, J.; Schacht, P.; Schachtner, B. M.; Schaefer, D.; Schaefer, L.; Schaeffer, J.; Schaepe, S.; Schäfer, U.; Schaffer, A. C.; Schaile, D.; Schamberger, R. D.; Schegelsky, V. A.; Scheirich, D.; Schenck, F.; Schernau, M.; Schiavi, C.; Schier, S.; Schildgen, L. K.; Schillaci, Z. M.; Schillo, C.; Schioppa, E. J.; Schioppa, M.; Schleicher, K. E.; Schlenker, S.; Schmidt-Sommerfeld, K. R.; Schmieden, K.; Schmitt, C.; Schmitt, S.; Schmitz, S.; Schnoor, U.; Schoeffel, L.; Schoening, A.; Schopf, E.; Schott, M.; Schouwenberg, J. F. P.; Schovancova, J.; Schramm, S.; Schuh, N.; Schulte, A.; Schultz-Coulon, H.-C.; Schumacher, M.; Schumm, B. A.; Schune, Ph.; Schwartzman, A.; Schwarz, T. A.; Schweiger, H.; Schwemling, Ph.; Schwienhorst, R.; Schwindling, J.; Sciandra, A.; Sciolla, G.; Scornajenghi, M.; Scuri, F.; Scutti, F.; Scyboz, L. M.; Searcy, J.; Seema, P.; Seidel, S. C.; Seiden, A.; Seixas, J. M.; Sekhniaidze, G.; Sekhon, K.; Sekula, S. J.; Semprini-Cesari, N.; Senkin, S.; Serfon, C.; Serin, L.; Serkin, L.; Sessa, M.; Severini, H.; Šfiligoj, T.; Sforza, F.; Sfyrla, A.; Shabalina, E.; Shahinian, J. D.; Shaikh, N. W.; Shan, L. Y.; Shang, R.; Shank, J. T.; Shapiro, M.; Sharma, A. S.; Shatalov, P. B.; Shaw, K.; Shaw, S. M.; Shcherbakova, A.; Shehu, C. Y.; Shen, Y.; Sherafati, N.; Sherman, A. D.; Sherwood, P.; Shi, L.; Shimizu, S.; Shimmin, C. O.; Shimojima, M.; Shipsey, I. P. J.; Shirabe, S.; Shiyakova, M.; Shlomi, J.; Shmeleva, A.; Shoaleh Saadi, D.; Shochet, M. J.; Shojaii, S.; Shope, D. R.; Shrestha, S.; Shulga, E.; Sicho, P.; Sickles, A. M.; Sidebo, P. E.; Sideras Haddad, E.; Sidiropoulou, O.; Sidoti, A.; Siegert, F.; Sijacki, Dj.; Silva, J.; Silva, M.; Silverstein, S. B.; Simic, L.; Simion, S.; Simioni, E.; Simmons, B.; Simon, M.; Sinervo, P.; Sinev, N. B.; Sioli, M.; Siragusa, G.; Siral, I.; Sivoklokov, S. Yu.; Sjölin, J.; Skinner, M. B.; Skubic, P.; Slater, M.; Slavicek, T.; Slawinska, M.; Sliwa, K.; Slovak, R.; Smakhtin, V.; Smart, B. H.; Smiesko, J.; Smirnov, N.; Smirnov, S. Yu.; Smirnov, Y.; Smirnova, L. N.; Smirnova, O.; Smith, J. W.; Smith, M. N. K.; Smith, R. W.; Smizanska, M.; Smolek, K.; Snesarev, A. A.; Snyder, I. M.; Snyder, S.; Sobie, R.; Socher, F.; Soffa, A. M.; Soffer, A.; Søgaard, A.; Soh, D. A.; Sokhrannyi, G.; Solans Sanchez, C. A.; Solar, M.; Soldatov, E. Yu.; Soldevila, U.; Solodkov, A. A.; Soloshenko, A.; Solovyanov, O. V.; Solovyev, V.; Sommer, P.; Son, H.; Song, W.; Sopczak, A.; Sopkova, F.; Sosa, D.; Sotiropoulou, C. L.; Sottocornola, S.; Soualah, R.; Soukharev, A. M.; South, D.; Sowden, B. C.; Spagnolo, S.; Spalla, M.; Spangenberg, M.; Spanò, F.; Sperlich, D.; Spettel, F.; Spieker, T. M.; Spighi, R.; Spigo, G.; Spiller, L. A.; Spousta, M.; St. Denis, R. D.; Stabile, A.; Stamen, R.; Stamm, S.; Stanecka, E.; Stanek, R. W.; Stanescu, C.; Stanitzki, M. M.; Stapf, B. S.; Stapnes, S.; Starchenko, E. A.; Stark, G. H.; Stark, J.; Stark, S. H.; Staroba, P.; Starovoitov, P.; Stärz, S.; Staszewski, R.; Stegler, M.; Steinberg, P.; Stelzer, B.; Stelzer, H. J.; Stelzer-Chilton, O.; Stenzel, H.; Stevenson, T. J.; Stewart, G. A.; Stockton, M. C.; Stoicea, G.; Stolte, P.; Stonjek, S.; Straessner, A.; Stramaglia, M. E.; Strandberg, J.; Strandberg, S.; Strauss, M.; Strizenec, P.; Ströhmer, R.; Strom, D. M.; Stroynowski, R.; Strubig, A.; Stucci, S. A.; Stugu, B.; Styles, N. A.; Su, D.; Su, J.; Suchek, S.; Sugaya, Y.; Suk, M.; Sulin, V. V.; Sultan, D. M. S.; Sultansoy, S.; Sumida, T.; Sun, S.; Sun, X.; Suruliz, K.; Suster, C. J. E.; Sutton, M. R.; Suzuki, S.; Svatos, M.; Swiatlowski, M.; Swift, S. P.; Sydorenko, A.; Sykora, I.; Sykora, T.; Ta, D.; Tackmann, K.; Taenzer, J.; Taffard, A.; Tafirout, R.; Tahirovic, E.; Taiblum, N.; Takai, H.; Takashima, R.; Takasugi, E. H.; Takeda, K.; Takeshita, T.; Takubo, Y.; Talby, M.; Talyshev, A. A.; Tanaka, J.; Tanaka, M.; Tanaka, R.; Tanioka, R.; Tannenwald, B. B.; Tapia Araya, S.; Tapprogge, S.; Tarek Abouelfadl Mohamed, A. T.; Tarem, S.; Tarna, G.; Tartarelli, G. F.; Tas, P.; Tasevsky, M.; Tashiro, T.; Tassi, E.; Tavares Delgado, A.; Tayalati, Y.; Taylor, A. C.; Taylor, A. J.; Taylor, G. N.; Taylor, P. T. E.; Taylor, W.; Teixeira-Dias, P.; Temple, D.; Ten Kate, H.; Teng, P. K.; Teoh, J. J.; Tepel, F.; Terada, S.; Terashi, K.; Terron, J.; Terzo, S.; Testa, M.; Teuscher, R. J.; Thais, S. J.; Theveneaux-Pelzer, T.; Thiele, F.; Thomas, J. P.; Thompson, P. D.; Thompson, A. S.; Thomsen, L. A.; Thomson, E.; Tian, Y.; Ticse Torres, R. E.; Tikhomirov, V. O.; Tikhonov, Yu. A.; Timoshenko, S.; Tipton, P.; Tisserant, S.; Todome, K.; Todorova-Nova, S.; Todt, S.; Tojo, J.; Tokár, S.; Tokushuku, K.; Tolley, E.; Tomoto, M.; Tompkins, L.; Toms, K.; Tong, B.; Tornambe, P.; Torrence, E.; Torres, H.; Torró Pastor, E.; Toth, J.; Touchard, F.; Tovey, D. R.; Treado, C. J.; Trefzger, T.; Tresoldi, F.; Tricoli, A.; Trigger, I. M.; Trincaz-Duvoid, S.; Tripiana, M. F.; Trischuk, W.; Trocmé, B.; Trofymov, A.; Troncon, C.; Trovatelli, M.; Truong, L.; Trzebinski, M.; Trzupek, A.; Tsang, K. W.; Tseng, J. C.-L.; Tsiareshka, P. V.; Tsirintanis, N.; Tsiskaridze, S.; Tsiskaridze, V.; Tskhadadze, E. G.; Tsukerman, I. I.; Tsulaia, V.; Tsuno, S.; Tsybychev, D.; Tu, Y.; Tudorache, A.; Tudorache, V.; Tulbure, T. T.; Tuna, A. N.; Turchikhin, S.; Turgeman, D.; Turk Cakir, I.; Turra, R.; Tuts, P. M.; Ucchielli, G.; Ueda, I.; Ughetto, M.; Ukegawa, F.; Unal, G.; Undrus, A.; Unel, G.; Ungaro, F. C.; Unno, Y.; Uno, K.; Urban, J.; Urquijo, P.; Urrejola, P.; Usai, G.; Usui, J.; Vacavant, L.; Vacek, V.; Vachon, B.; Vadla, K. O. H.; Vaidya, A.; Valderanis, C.; Valdes Santurio, E.; Valente, M.; Valentinetti, S.; Valero, A.; Valéry, L.; Vallier, A.; Valls Ferrer, J. A.; van den Wollenberg, W.; van der Graaf, H.; van Gemmeren, P.; van Nieuwkoop, J.; van Vulpen, I.; van Woerden, M. C.; Vanadia, M.; Vandelli, W.; Vaniachine, A.; Vankov, P.; Vari, R.; Varnes, E. W.; Varni, C.; Varol, T.; Varouchas, D.; Vartapetian, A.; Varvell, K. E.; Vasquez, J. G.; Vasquez, G. A.; Vazeille, F.; Vazquez Furelos, D.; Vazquez Schroeder, T.; Veatch, J.; Vecchio, V.; Veloce, L. M.; Veloso, F.; Veneziano, S.; Ventura, A.; Venturi, M.; Venturi, N.; Vercesi, V.; Verducci, M.; Verkerke, W.; Vermeulen, A. T.; Vermeulen, J. C.; Vetterli, M. C.; Viaux Maira, N.; Viazlo, O.; Vichou, I.; Vickey, T.; Vickey Boeriu, O. E.; Viehhauser, G. H. A.; Viel, S.; Vigani, L.; Villa, M.; Villaplana Perez, M.; Vilucchi, E.; Vincter, M. G.; Vinogradov, V. B.; Vishwakarma, A.; Vittori, C.; Vivarelli, I.; Vlachos, S.; Vogel, M.; Vokac, P.; Volpi, G.; von Buddenbrock, S. E.; von Toerne, E.; Vorobel, V.; Vorobev, K.; Vos, M.; Vossebeld, J. H.; Vranjes, N.; Vranjes Milosavljevic, M.; Vrba, V.; Vreeswijk, M.; Vuillermet, R.; Vukotic, I.; Wagner, P.; Wagner, W.; Wagner-Kuhr, J.; Wahlberg, H.; Wahrmund, S.; Wakamiya, K.; Walder, J.; Walker, R.; Walkowiak, W.; Wallangen, V.; Wang, A. M.; Wang, C.; Wang, F.; Wang, H.; Wang, H.; Wang, J.; Wang, J.; Wang, Q.; Wang, R.-J.; Wang, R.; Wang, S. M.; Wang, T.; Wang, W.; Wang, W.; Wang, Z.; Wanotayaroj, C.; Warburton, A.; Ward, C. P.; Wardrope, D. R.; Washbrook, A.; Watkins, P. M.; Watson, A. T.; Watson, M. F.; Watts, G.; Watts, S.; Waugh, B. M.; Webb, A. F.; Webb, S.; Weber, M. S.; Weber, S. M.; Weber, S. A.; Webster, J. S.; Weidberg, A. R.; Weinert, B.; Weingarten, J.; Weirich, M.; Weiser, C.; Wells, P. S.; Wenaus, T.; Wengler, T.; Wenig, S.; Wermes, N.; Werner, M. D.; Werner, P.; Wessels, M.; Weston, T. D.; Whalen, K.; Whallon, N. L.; Wharton, A. M.; White, A. S.; White, A.; White, M. J.; White, R.; Whiteson, D.; Whitmore, B. W.; Wickens, F. J.; Wiedenmann, W.; Wielers, M.; Wiglesworth, C.; Wiik-Fuchs, L. A. M.; Wildauer, A.; Wilk, F.; Wilkens, H. G.; Williams, H. H.; Williams, S.; Willis, C.; Willocq, S.; Wilson, J. A.; Wingerter-Seez, I.; Winkels, E.; Winklmeier, F.; Winston, O. J.; Winter, B. T.; Wittgen, M.; Wobisch, M.; Wolf, A.; Wolf, T. M. H.; Wolff, R.; Wolter, M. W.; Wolters, H.; Wong, V. W. S.; Woods, N. L.; Worm, S. D.; Wosiek, B. K.; Wozniak, K. W.; Wu, M.; Wu, S. L.; Wu, X.; Wu, Y.; Wyatt, T. R.; Wynne, B. M.; Xella, S.; Xi, Z.; Xia, L.; Xu, D.; Xu, L.; Xu, T.; Xu, W.; Yabsley, B.; Yacoob, S.; Yajima, K.; Yallup, D. P.; Yamaguchi, D.; Yamaguchi, Y.; Yamamoto, A.; Yamanaka, T.; Yamane, F.; Yamatani, M.; Yamazaki, T.; Yamazaki, Y.; Yan, Z.; Yang, H.; Yang, H.; Yang, S.; Yang, Y.; Yang, Z.; Yao, W.-M.; Yap, Y. C.; Yasu, Y.; Yatsenko, E.; Yau Wong, K. H.; Ye, J.; Ye, S.; Yeletskikh, I.; Yigitbasi, E.; Yildirim, E.; Yorita, K.; Yoshihara, K.; Young, C.; Young, C. J. S.; Yu, J.; Yu, J.; Yuen, S. P. Y.; Yusuff, I.; Zabinski, B.; Zacharis, G.; Zaidan, R.; Zaitsev, A. M.; Zakharchuk, N.; Zalieckas, J.; Zambito, S.; Zanzi, D.; Zeitnitz, C.; Zemaityte, G.; Zeng, J. C.; Zeng, Q.; Zenin, O.; Ženiš, T.; Zerwas, D.; Zhang, D.; Zhang, D.; Zhang, F.; Zhang, G.; Zhang, H.; Zhang, J.; Zhang, L.; Zhang, L.; Zhang, M.; Zhang, P.; Zhang, R.; Zhang, R.; Zhang, X.; Zhang, Y.; Zhang, Z.; Zhao, X.; Zhao, Y.; Zhao, Z.; Zhemchugov, A.; Zhou, B.; Zhou, C.; Zhou, L.; Zhou, M.; Zhou, M.; Zhou, N.; Zhou, Y.; Zhu, C. G.; Zhu, H.; Zhu, J.; Zhu, Y.; Zhuang, X.; Zhukov, K.; Zhulanov, V.; Zibell, A.; Zieminska, D.; Zimine, N. I.; Zimmermann, S.; Zinonos, Z.; Zinser, M.; Ziolkowski, M.; Živković, L.; Zobernig, G.; Zoccoli, A.; Zou, R.; Zur Nedden, M.; Zwalinski, L.; Atlas Collaboration
2018-04-01
A search for the associated production of the Higgs boson with a top quark pair (t t ¯H ) is reported. The search is performed in multilepton final states using a data set corresponding to an integrated luminosity of 36.1 fb-1 of proton-proton collision data recorded by the ATLAS experiment at a center-of-mass energy √{s }=13 TeV at the Large Hadron Collider. Higgs boson decays to W W*, τ τ , and Z Z* are targeted. Seven final states, categorized by the number and flavor of charged-lepton candidates, are examined for the presence of the Standard Model Higgs boson with a mass of 125 GeV and a pair of top quarks. An excess of events over the expected background from Standard Model processes is found with an observed significance of 4.1 standard deviations, compared to an expectation of 2.8 standard deviations. The best fit for the t t ¯H production cross section is σ (t t ¯H )=79 0-210+230 fb , in agreement with the Standard Model prediction of 50 7-50+35 fb . The combination of this result with other t t ¯H searches from the ATLAS experiment using the Higgs boson decay modes to b b ¯, γ γ and Z Z*→4 ℓ, has an observed significance of 4.2 standard deviations, compared to an expectation of 3.8 standard deviations. This provides evidence for the t t ¯H production mode.
Weld pool oscillation during pulsed GTA welding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aendenroomer, A.J.R.; Ouden, G. den
1996-12-31
This paper deals with weld pool oscillation during pulsed GTA welding and with the possibility to use this oscillation for in-process control of weld penetration. Welding experiments were carried out under different welding conditions. During welding the weld pool was triggered into oscillation by the normal welding pulses or by extra current pulses. The oscillation frequency was measured both during the pulse time and during the base time by analyzing the arc voltage variation using a Fast Fourier Transformation program. Optimal results are obtained when full penetration occurs during the pulse time and partial penetration during the base time. Undermore » these conditions elliptical overlapping spot welds are formed. In the case of full penetration the weld pool oscillates in a low frequency mode (membrane oscillation), whereas in the case of partial penetration the weld pool oscillates in a high frequency mode (surface oscillation). Deviation from the optimal welding conditions occurs when high frequency oscillation is observed during both pulse time and base time (underpenetration) or when low frequency oscillation is observed during both pulse time and base time (overpenetration). In line with these results a penetration sensing system with feedback control was designed, based on the criterion that optimal weld penetration is achieved when two peaks are observed in the frequency distribution. The feasibility of this sensing system for orbital tube welding was confirmed by the results of experiments carried out under various welding conditions.« less
WASP (Write a Scientific Paper) using Excel -5: Quartiles and standard deviation.
Grech, Victor
2018-03-01
The almost inevitable descriptive statistics exercise that is undergone once data collection is complete, prior to inferential statistics, requires the acquisition of basic descriptors which may include standard deviation and quartiles. This paper provides pointers as to how to do this in Microsoft Excel™ and explains the relationship between the two. Copyright © 2018 Elsevier B.V. All rights reserved.
Validation Test Report for GDEM4
2010-08-19
standard deviations called the Generalized Digital Environmental Model ( GDEM ). The present document describes the development and evaluation of GDEM4...the newest version of GDEM . As part of the evaluation of GDEM4, comparisons are made in this report to GDEM3 and to four other ocean climatologies...depth climatology of temperature and salinity and their standard deviations called the Generalized Digital Environmental Model ( GDEM ). The history of
40 CFR 91.508 - Cumulative Sum (CumSum) procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... family may be determined to be in noncompliance for purposes of § 91.510. H = The Action Limit. It is 5.0 × σ, and is a function of the standard deviation, σ. σ = is the sample standard deviation and is... Equation must be final deteriorated test results as defined in § 91.509(c). Ci = max[0 0R (Ci-1 + Xi − (FEL...
NASA Astrophysics Data System (ADS)
Larsson, R.; Milz, M.; Rayer, P.; Saunders, R.; Bell, W.; Booton, A.; Buehler, S. A.; Eriksson, P.; John, V.
2015-10-01
We present a comparison of a reference and a fast radiative transfer model using numerical weather prediction profiles for the Zeeman-affected high altitude Special Sensor Microwave Imager/Sounder channels 19-22. We find that the models agree well for channels 21 and 22 compared to the channels' system noise temperatures (1.9 and 1.3 K, respectively) and the expected profile errors at the affected altitudes (estimated to be around 5 K). For channel 22 there is a 0.5 K average difference between the models, with a standard deviation of 0.24 K for the full set of atmospheric profiles. Same channel, there is 1.2 K in average between the fast model and the sensor measurement, with 1.4 K standard deviation. For channel 21 there is a 0.9 K average difference between the models, with a standard deviation of 0.56 K. Same channel, there is 1.3 K in average between the fast model and the sensor measurement, with 2.4 K standard deviation. We consider the relatively small model differences as a validation of the fast Zeeman effect scheme for these channels. Both channels 19 and 20 have smaller average differences between the models (at below 0.2 K) and smaller standard deviations (at below 0.4 K) when both models use a two-dimensional magnetic field profile. However, when the reference model is switched to using a full three-dimensional magnetic field profile, the standard deviation to the fast model is increased to almost 2 K due to viewing geometry dependencies causing up to ± 7 K differences near the equator. The average differences between the two models remain small despite changing magnetic field configurations. We are unable to compare channels 19 and 20 to sensor measurements due to limited altitude range of the numerical weather prediction profiles. We recommended that numerical weather prediction software using the fast model takes the available fast Zeeman scheme into account for data assimilation of the affected sensor channels to better constrain the upper atmospheric temperatures.
NASA Astrophysics Data System (ADS)
Larsson, Richard; Milz, Mathias; Rayer, Peter; Saunders, Roger; Bell, William; Booton, Anna; Buehler, Stefan A.; Eriksson, Patrick; John, Viju O.
2016-03-01
We present a comparison of a reference and a fast radiative transfer model using numerical weather prediction profiles for the Zeeman-affected high-altitude Special Sensor Microwave Imager/Sounder channels 19-22. We find that the models agree well for channels 21 and 22 compared to the channels' system noise temperatures (1.9 and 1.3 K, respectively) and the expected profile errors at the affected altitudes (estimated to be around 5 K). For channel 22 there is a 0.5 K average difference between the models, with a standard deviation of 0.24 K for the full set of atmospheric profiles. Concerning the same channel, there is 1.2 K on average between the fast model and the sensor measurement, with 1.4 K standard deviation. For channel 21 there is a 0.9 K average difference between the models, with a standard deviation of 0.56 K. Regarding the same channel, there is 1.3 K on average between the fast model and the sensor measurement, with 2.4 K standard deviation. We consider the relatively small model differences as a validation of the fast Zeeman effect scheme for these channels. Both channels 19 and 20 have smaller average differences between the models (at below 0.2 K) and smaller standard deviations (at below 0.4 K) when both models use a two-dimensional magnetic field profile. However, when the reference model is switched to using a full three-dimensional magnetic field profile, the standard deviation to the fast model is increased to almost 2 K due to viewing geometry dependencies, causing up to ±7 K differences near the equator. The average differences between the two models remain small despite changing magnetic field configurations. We are unable to compare channels 19 and 20 to sensor measurements due to limited altitude range of the numerical weather prediction profiles. We recommended that numerical weather prediction software using the fast model takes the available fast Zeeman scheme into account for data assimilation of the affected sensor channels to better constrain the upper atmospheric temperatures.
Spectral combination of spherical gravitational curvature boundary-value problems
NASA Astrophysics Data System (ADS)
PitoÅák, Martin; Eshagh, Mehdi; Šprlák, Michal; Tenzer, Robert; Novák, Pavel
2018-04-01
Four solutions of the spherical gravitational curvature boundary-value problems can be exploited for the determination of the Earth's gravitational potential. In this article we discuss the combination of simulated satellite gravitational curvatures, i.e., components of the third-order gravitational tensor, by merging these solutions using the spectral combination method. For this purpose, integral estimators of biased- and unbiased-types are derived. In numerical studies, we investigate the performance of the developed mathematical models for the gravitational field modelling in the area of Central Europe based on simulated satellite measurements. Firstly, we verify the correctness of the integral estimators for the spectral downward continuation by a closed-loop test. Estimated errors of the combined solution are about eight orders smaller than those from the individual solutions. Secondly, we perform a numerical experiment by considering the Gaussian noise with the standard deviation of 6.5× 10-17 m-1s-2 in the input data at the satellite altitude of 250 km above the mean Earth sphere. This value of standard deviation is equivalent to a signal-to-noise ratio of 10. Superior results with respect to the global geopotential model TIM-r5 are obtained by the spectral downward continuation of the vertical-vertical-vertical component with the standard deviation of 2.104 m2s-2, but the root mean square error is the largest and reaches 9.734 m2s-2. Using the spectral combination of all gravitational curvatures the root mean square error is more than 400 times smaller but the standard deviation reaches 17.234 m2s-2. The combination of more components decreases the root mean square error of the corresponding solutions while the standard deviations of the combined solutions do not improve as compared to the solution from the vertical-vertical-vertical component. The presented method represents a weight mean in the spectral domain that minimizes the root mean square error of the combined solutions and improves standard deviation of the solution based only on the least accurate components.
NASA Astrophysics Data System (ADS)
Stier, P.; Schutgens, N. A. J.; Bellouin, N.; Bian, H.; Boucher, O.; Chin, M.; Ghan, S.; Huneeus, N.; Kinne, S.; Lin, G.; Ma, X.; Myhre, G.; Penner, J. E.; Randles, C. A.; Samset, B.; Schulz, M.; Takemura, T.; Yu, F.; Yu, H.; Zhou, C.
2013-03-01
Simulated multi-model "diversity" in aerosol direct radiative forcing estimates is often perceived as a measure of aerosol uncertainty. However, current models used for aerosol radiative forcing calculations vary considerably in model components relevant for forcing calculations and the associated "host-model uncertainties" are generally convoluted with the actual aerosol uncertainty. In this AeroCom Prescribed intercomparison study we systematically isolate and quantify host model uncertainties on aerosol forcing experiments through prescription of identical aerosol radiative properties in twelve participating models. Even with prescribed aerosol radiative properties, simulated clear-sky and all-sky aerosol radiative forcings show significant diversity. For a purely scattering case with globally constant optical depth of 0.2, the global-mean all-sky top-of-atmosphere radiative forcing is -4.47 Wm-2 and the inter-model standard deviation is 0.55 Wm-2, corresponding to a relative standard deviation of 12%. For a case with partially absorbing aerosol with an aerosol optical depth of 0.2 and single scattering albedo of 0.8, the forcing changes to 1.04 Wm-2, and the standard deviation increases to 1.01 W-2, corresponding to a significant relative standard deviation of 97%. However, the top-of-atmosphere forcing variability owing to absorption (subtracting the scattering case from the case with scattering and absorption) is low, with absolute (relative) standard deviations of 0.45 Wm-2 (8%) clear-sky and 0.62 Wm-2 (11%) all-sky. Scaling the forcing standard deviation for a purely scattering case to match the sulfate radiative forcing in the AeroCom Direct Effect experiment demonstrates that host model uncertainties could explain about 36% of the overall sulfate forcing diversity of 0.11 Wm-2 in the AeroCom Direct Radiative Effect experiment. Host model errors in aerosol radiative forcing are largest in regions of uncertain host model components, such as stratocumulus cloud decks or areas with poorly constrained surface albedos, such as sea ice. Our results demonstrate that host model uncertainties are an important component of aerosol forcing uncertainty that require further attention.
Quantifying the heterogeneity of the tectonic stress field using borehole data
Schoenball, Martin; Davatzes, Nicholas C.
2017-01-01
The heterogeneity of the tectonic stress field is a fundamental property which influences earthquake dynamics and subsurface engineering. Self-similar scaling of stress heterogeneities is frequently assumed to explain characteristics of earthquakes such as the magnitude-frequency relation. However, observational evidence for such scaling of the stress field heterogeneity is scarce.We analyze the local stress orientations using image logs of two closely spaced boreholes in the Coso Geothermal Field with sub-vertical and deviated trajectories, respectively, each spanning about 2 km in depth. Both the mean and the standard deviation of stress orientation indicators (borehole breakouts, drilling-induced fractures and petal-centerline fractures) determined from each borehole agree to the limit of the resolution of our method although measurements at specific depths may not. We find that the standard deviation in these boreholes strongly depends on the interval length analyzed, generally increasing up to a wellbore log length of about 600 m and constant for longer intervals. We find the same behavior in global data from the World Stress Map. This suggests that the standard deviation of stress indicators characterizes the heterogeneity of the tectonic stress field rather than the quality of the stress measurement. A large standard deviation of a stress measurement might be an expression of strong crustal heterogeneity rather than of an unreliable stress determination. Robust characterization of stress heterogeneity requires logs that sample stress indicators along a representative sample volume of at least 1 km.
NASA Astrophysics Data System (ADS)
Brooks, Andrew P.; Howell, Timothy; Abbe, Tim B.; Arthington, Angela H.
2006-09-01
This study evaluates an experiment in river rehabilitation which uses large wood to stimulate and emulate natural system processes in an effort to reverse channel degradation, excess sediment transport and habitat simplification that has resulted from two centuries of human induced disturbances, particularly desnagging. The experiment involved the reintroduction of 436 logs (350 t) within 20 engineered log jams (ELJs) over an 1100 m reach. Commencing in 1999, the experiment was set up as a standard BACI design, with a control reach 3 km upstream. In the 5 years since implementing the rehabilitation strategy, the study reach has experienced five floods greater than the mean annual, and a further five events capable of mobilising the gravel bed. Five surveys of channel terrain have been completed since treatment implementation, and the changes to net sediment storage and morphologic diversity assessed in comparison to the control reach. Seven surveys of the fish population in the reach have also been undertaken during the project to measure the ecological response to the introduced wood. The experiment has demonstrated the effectiveness of ELJ technology in achieving engineering and geomorphic goals. To date, the treatment has halted further degradation of the river and increased sediment storage, with the test reach now storing, on average, 40 m 3/1000 m 2 more sediment than in the control. These values, it would appear, represent a new reach-scale dynamic equilibrium storage level over decadal timescales. Additional sediment storage amounts to 3.5 m 3/m 3 of wood added. At the reach scale this additional storage represents a reduction of just 2% or less of the post-European expansion in channel capacity, suggesting far greater efforts are required than those employed here to reverse the cumulative effects of 180 years of channel erosion and simplification. Pool and bar area in the test reach increased by around 5% and 3.5%, respectively, while the corresponding values in the control were around 1.5% and 1%, respectively. Two indices of morphologic diversity were measured for each bed survey: the standard deviation of 3D residuals of change compared with the baseline survey (SD iΔ3D); and the standard deviation of thalweg residuals from the line of best fit (SD iTR). The SD iΔ3D index shows both reaches increased in complexity through the study with the treatment increasing more than the control (0.37 and 0.29, respectively). The SD iTR index does not detect clear changes because of the low signal to noise ratio, however, it does suggest the test reach was more complex than the control at the outset. The observed increase in fish abundance after the first 12 months of monitoring, reported previously, is now far less distinct 4 years on — a pattern seemingly reflecting the relatively minor increases in critical pool habitat and habitat diversity over the same period. Although no significant differences were detectable in fish species richness or total abundance from the reach aggregate data after 4 years, analysis of individual structures show them to be high quality habitat for native fish compared to the rest of the reach and the upstream control. These results highlight the challenges river managers face in achieving measurable improvements in the health of aquatic ecosystems in highly altered rivers. Managers must confront hysteresis in a biophysical and institutional sense when attempting to reverse the degradation of rivers. The scale of treatment implemented in this experiment was at the upper end of the spectrum of rehabilitation efforts currently being undertaken in Australia, suggesting that far greater resources and longer timescales are required to achieve the levels of improvement in the diversity of stream habitat expected by the community. The study also highlights problems with the strategy of attempting to meet multiple objectives within a reach scale rehabilitation project. While this treatment successfully met some geomorphic study objectives, maximising the benefits for fish habitat would require a strategy focused primarily on the creation of complex woody habitat within deeper pools, particularly pools immediately below riffles.
NASA Astrophysics Data System (ADS)
Cécillon, Lauric; Baudin, François; Chenu, Claire; Houot, Sabine; Jolivet, Romain; Kätterer, Thomas; Lutfalla, Suzanne; Macdonald, Andy; van Oort, Folkert; Plante, Alain F.; Savignac, Florence; Soucémarianadin, Laure N.; Barré, Pierre
2018-05-01
Changes in global soil carbon stocks have considerable potential to influence the course of future climate change. However, a portion of soil organic carbon (SOC) has a very long residence time ( > 100 years) and may not contribute significantly to terrestrial greenhouse gas emissions during the next century. The size of this persistent SOC reservoir is presumed to be large. Consequently, it is a key parameter required for the initialization of SOC dynamics in ecosystem and Earth system models, but there is considerable uncertainty in the methods used to quantify it. Thermal analysis methods provide cost-effective information on SOC thermal stability that has been shown to be qualitatively related to SOC biogeochemical stability. The objective of this work was to build the first quantitative model of the size of the centennially persistent SOC pool based on thermal analysis. We used a unique set of 118 archived soil samples from four agronomic experiments in northwestern Europe with long-term bare fallow and non-bare fallow treatments (e.g., manure amendment, cropland and grassland) as a sample set for which estimating the size of the centennially persistent SOC pool is relatively straightforward. At each experimental site, we estimated the average concentration of centennially persistent SOC and its uncertainty by applying a Bayesian curve-fitting method to the observed declining SOC concentration over the duration of the long-term bare fallow treatment. Overall, the estimated concentrations of centennially persistent SOC ranged from 5 to 11 g C kg-1 of soil (lowest and highest boundaries of four 95 % confidence intervals). Then, by dividing the site-specific concentrations of persistent SOC by the total SOC concentration, we could estimate the proportion of centennially persistent SOC in the 118 archived soil samples and the associated uncertainty. The proportion of centennially persistent SOC ranged from 0.14 (standard deviation of 0.01) to 1 (standard deviation of 0.15). Samples were subjected to thermal analysis by Rock-Eval 6 that generated a series of 30 parameters reflecting their SOC thermal stability and bulk chemistry. We trained a nonparametric machine-learning algorithm (random forests multivariate regression model) to predict the proportion of centennially persistent SOC in new soils using Rock-Eval 6 thermal parameters as predictors. We evaluated the model predictive performance with two different strategies. We first used a calibration set (n = 88) and a validation set (n = 30) with soils from all sites. Second, to test the sensitivity of the model to pedoclimate, we built a calibration set with soil samples from three out of the four sites (n = 84). The multivariate regression model accurately predicted the proportion of centennially persistent SOC in the validation set composed of soils from all sites (R2 = 0.92, RMSEP = 0.07, n = 30). The uncertainty of the model predictions was quantified by a Monte Carlo approach that produced conservative 95 % prediction intervals across the validation set. The predictive performance of the model decreased when predicting the proportion of centennially persistent SOC in soils from one fully independent site with a different pedoclimate, yet the mean error of prediction only slightly increased (R2 = 0.53, RMSEP = 0.10, n = 34). This model based on Rock-Eval 6 thermal analysis can thus be used to predict the proportion of centennially persistent SOC with known uncertainty in new soil samples from different pedoclimates, at least for sites that have similar Rock-Eval 6 thermal characteristics to those included in the calibration set. Our study reinforces the evidence that there is a link between the thermal and biogeochemical stability of soil organic matter and demonstrates that Rock-Eval 6 thermal analysis can be used to quantify the size of the centennially persistent organic carbon pool in temperate soils.
Algicidal and Sanitizing Properties of Armazide1
Antonides, H. J.; Tanner, W. S.
1961-01-01
Algicidal and sanitizing properties of Armazide, a new swimming pool additive, consisting of 12% w/v each of dodecylamine hydrochloride, trimethyl alkyl ammonium chloride, and methyl alkyl dipolyoxypropylene ammonium methyl sulfate in solution, were evaluated by laboratory techniques against algae and sewage. Results indicated it to be highly effective in low concentrations especially in conjunction with low concentrations of chlorine. Swimming pool field tests were found to confirm the laboratory findings. Various treatment levels and methods are described for swimming pools using treatments based upon the actual condition of the pool and water. The use of the product permitted a reduction in chlorine residual in pools resulting in greatly reduced requirements for chlorinating chemicals along with absence of irritation, odor, and other undesirable results usually associated with standard pool chlorination methods. PMID:13861802
Size-dependent standard deviation for growth rates: Empirical results and theoretical modeling
NASA Astrophysics Data System (ADS)
Podobnik, Boris; Horvatic, Davor; Pammolli, Fabio; Wang, Fengzhong; Stanley, H. Eugene; Grosse, I.
2008-05-01
We study annual logarithmic growth rates R of various economic variables such as exports, imports, and foreign debt. For each of these variables we find that the distributions of R can be approximated by double exponential (Laplace) distributions in the central parts and power-law distributions in the tails. For each of these variables we further find a power-law dependence of the standard deviation σ(R) on the average size of the economic variable with a scaling exponent surprisingly close to that found for the gross domestic product (GDP) [Phys. Rev. Lett. 81, 3275 (1998)]. By analyzing annual logarithmic growth rates R of wages of 161 different occupations, we find a power-law dependence of the standard deviation σ(R) on the average value of the wages with a scaling exponent β≈0.14 close to those found for the growth of exports, imports, debt, and the growth of the GDP. In contrast to these findings, we observe for payroll data collected from 50 states of the USA that the standard deviation σ(R) of the annual logarithmic growth rate R increases monotonically with the average value of payroll. However, also in this case we observe a power-law dependence of σ(R) on the average payroll with a scaling exponent β≈-0.08 . Based on these observations we propose a stochastic process for multiple cross-correlated variables where for each variable (i) the distribution of logarithmic growth rates decays exponentially in the central part, (ii) the distribution of the logarithmic growth rate decays algebraically in the far tails, and (iii) the standard deviation of the logarithmic growth rate depends algebraically on the average size of the stochastic variable.
Pardo, Deborah; Jenouvrier, Stéphanie; Weimerskirch, Henri; Barbraud, Christophe
2017-06-19
Climate changes include concurrent changes in environmental mean, variance and extremes, and it is challenging to understand their respective impact on wild populations, especially when contrasted age-dependent responses to climate occur. We assessed how changes in mean and standard deviation of sea surface temperature (SST), frequency and magnitude of warm SST extreme climatic events (ECE) influenced the stochastic population growth rate log( λ s ) and age structure of a black-browed albatross population. For changes in SST around historical levels observed since 1982, changes in standard deviation had a larger (threefold) and negative impact on log( λ s ) compared to changes in mean. By contrast, the mean had a positive impact on log( λ s ). The historical SST mean was lower than the optimal SST value for which log( λ s ) was maximized. Thus, a larger environmental mean increased the occurrence of SST close to this optimum that buffered the negative effect of ECE. This 'climate safety margin' (i.e. difference between optimal and historical climatic conditions) and the specific shape of the population growth rate response to climate for a species determine how ECE affect the population. For a wider range in SST, both the mean and standard deviation had negative impact on log( λ s ), with changes in the mean having a greater effect than the standard deviation. Furthermore, around SST historical levels increases in either mean or standard deviation of the SST distribution led to a younger population, with potentially important conservation implications for black-browed albatrosses.This article is part of the themed issue 'Behavioural, ecological and evolutionary responses to extreme climatic events'. © 2017 The Author(s).
Is standard deviation of daily PM2.5 concentration associated with respiratory mortality?
Lin, Hualiang; Ma, Wenjun; Qiu, Hong; Vaughn, Michael G; Nelson, Erik J; Qian, Zhengmin; Tian, Linwei
2016-09-01
Studies on health effects of air pollution often use daily mean concentration to estimate exposure while ignoring daily variations. This study examined the health effects of daily variation of PM2.5. We calculated daily mean and standard deviations of PM2.5 in Hong Kong between 1998 and 2011. We used a generalized additive model to estimate the association between respiratory mortality and daily mean and variation of PM2.5, as well as their interaction. We controlled for potential confounders, including temporal trends, day of the week, meteorological factors, and gaseous air pollutants. Both daily mean and standard deviation of PM2.5 were significantly associated with mortalities from overall respiratory diseases and pneumonia. Each 10 μg/m(3) increment in daily mean concentration at lag 2 day was associated with a 0.61% (95% CI: 0.19%, 1.03%) increase in overall respiratory mortality and a 0.67% (95% CI: 0.14%, 1.21%) increase in pneumonia mortality. And a 10 μg/m(3) increase in standard deviation at lag 1 day corresponded to a 1.40% (95% CI: 0.35%, 2.46%) increase in overall respiratory mortality, and a 1.80% (95% CI: 0.46%, 3.16%) increase in pneumonia mortality. We also observed a positive but non-significant synergistic interaction between daily mean and variation on respiratory mortality and pneumonia mortality. However, we did not find any significant association with mortality from chronic obstructive pulmonary diseases. Our study suggests that, besides mean concentration, the standard deviation of PM2.5 might be one potential predictor of respiratory mortality in Hong Kong, and should be considered when assessing the respiratory effects of PM2.5. Copyright © 2016 Elsevier Ltd. All rights reserved.
Assessment issues in the testing of children at school entry.
Rock, Donald A; Stenner, A Jackson
2005-01-01
The authors introduce readers to the research documenting racial and ethnic gaps in school readiness. They describe the key tests, including the Peabody Picture Vocabulary Test (PPVT), the Early Childhood Longitudinal Study (ECLS), and several intelligence tests, and describe how they have been administered to several important national samples of children. Next, the authors review the different estimates of the gaps and discuss how to interpret these differences. In interpreting test results, researchers use the statistical term "standard deviation" to compare scores across the tests. On average, the tests find a gap of about 1 standard deviation. The ECLS-K estimate is the lowest, about half a standard deviation. The PPVT estimate is the highest, sometimes more than 1 standard deviation. When researchers adjust those gaps statistically to take into account different outside factors that might affect children's test scores, such as family income or home environment, the gap narrows but does not disappear. Why such different estimates of the gap? The authors consider explanations such as differences in the samples, racial or ethnic bias in the tests, and whether the tests reflect different aspects of school "readiness," and conclude that none is likely to explain the varying estimates. Another possible explanation is the Spearman Hypothesis-that all tests are imperfect measures of a general ability construct, g; the more highly a given test correlates with g, the larger the gap will be. But the Spearman Hypothesis, too, leaves questions to be investigated. A gap of 1 standard deviation may not seem large, but the authors show clearly how it results in striking disparities in the performance of black and white students and why it should be of serious concern to policymakers.
Single-Station Sigma for the Iranian Strong Motion Stations
NASA Astrophysics Data System (ADS)
Zafarani, H.; Soghrat, M. R.
2017-11-01
In development of ground motion prediction equations (GMPEs), the residuals are assumed to have a log-normal distribution with a zero mean and a standard deviation, designated as sigma. Sigma has significant effect on evaluation of seismic hazard for designing important infrastructures such as nuclear power plants and dams. Both aleatory and epistemic uncertainties are involved in the sigma parameter. However, ground-motion observations over long time periods are not available at specific sites and the GMPEs have been derived using observed data from multiple sites for a small number of well-recorded earthquakes. Therefore, sigma is dominantly related to the statistics of the spatial variability of ground motion instead of temporal variability at a single point (ergodic assumption). The main purpose of this study is to reduce the variability of the residuals so as to handle it as epistemic uncertainty. In this regard, it is tried to partially apply the non-ergodic assumption by removing repeatable site effects from total variability of six GMPEs driven from the local, Europe-Middle East and worldwide data. For this purpose, we used 1837 acceleration time histories from 374 shallow earthquakes with moment magnitudes ranging from M w 4.0 to 7.3 recorded at 370 stations with at least two recordings per station. According to estimated single-station sigma for the Iranian strong motion stations, the ratio of event-corrected single-station standard deviation ( Φ ss) to within-event standard deviation ( Φ) is about 0.75. In other words, removing the ergodic assumption on site response resulted in 25% reduction of the within-event standard deviation that reduced the total standard deviation by about 15%.
Improving IQ measurement in intellectual disabilities using true deviation from population norms
2014-01-01
Background Intellectual disability (ID) is characterized by global cognitive deficits, yet the very IQ tests used to assess ID have limited range and precision in this population, especially for more impaired individuals. Methods We describe the development and validation of a method of raw z-score transformation (based on general population norms) that ameliorates floor effects and improves the precision of IQ measurement in ID using the Stanford Binet 5 (SB5) in fragile X syndrome (FXS; n = 106), the leading inherited cause of ID, and in individuals with idiopathic autism spectrum disorder (ASD; n = 205). We compared the distributional characteristics and Q-Q plots from the standardized scores with the deviation z-scores. Additionally, we examined the relationship between both scoring methods and multiple criterion measures. Results We found evidence that substantial and meaningful variation in cognitive ability on standardized IQ tests among individuals with ID is lost when converting raw scores to standardized scaled, index and IQ scores. Use of the deviation z- score method rectifies this problem, and accounts for significant additional variance in criterion validation measures, above and beyond the usual IQ scores. Additionally, individual and group-level cognitive strengths and weaknesses are recovered using deviation scores. Conclusion Traditional methods for generating IQ scores in lower functioning individuals with ID are inaccurate and inadequate, leading to erroneously flat profiles. However assessment of cognitive abilities is substantially improved by measuring true deviation in performance from standardization sample norms. This work has important implications for standardized test development, clinical assessment, and research for which IQ is an important measure of interest in individuals with neurodevelopmental disorders and other forms of cognitive impairment. PMID:26491488
Size-dependent standard deviation for growth rates: empirical results and theoretical modeling.
Podobnik, Boris; Horvatic, Davor; Pammolli, Fabio; Wang, Fengzhong; Stanley, H Eugene; Grosse, I
2008-05-01
We study annual logarithmic growth rates R of various economic variables such as exports, imports, and foreign debt. For each of these variables we find that the distributions of R can be approximated by double exponential (Laplace) distributions in the central parts and power-law distributions in the tails. For each of these variables we further find a power-law dependence of the standard deviation sigma(R) on the average size of the economic variable with a scaling exponent surprisingly close to that found for the gross domestic product (GDP) [Phys. Rev. Lett. 81, 3275 (1998)]. By analyzing annual logarithmic growth rates R of wages of 161 different occupations, we find a power-law dependence of the standard deviation sigma(R) on the average value of the wages with a scaling exponent beta approximately 0.14 close to those found for the growth of exports, imports, debt, and the growth of the GDP. In contrast to these findings, we observe for payroll data collected from 50 states of the USA that the standard deviation sigma(R) of the annual logarithmic growth rate R increases monotonically with the average value of payroll. However, also in this case we observe a power-law dependence of sigma(R) on the average payroll with a scaling exponent beta approximately -0.08 . Based on these observations we propose a stochastic process for multiple cross-correlated variables where for each variable (i) the distribution of logarithmic growth rates decays exponentially in the central part, (ii) the distribution of the logarithmic growth rate decays algebraically in the far tails, and (iii) the standard deviation of the logarithmic growth rate depends algebraically on the average size of the stochastic variable.
Improving IQ measurement in intellectual disabilities using true deviation from population norms.
Sansone, Stephanie M; Schneider, Andrea; Bickel, Erika; Berry-Kravis, Elizabeth; Prescott, Christina; Hessl, David
2014-01-01
Intellectual disability (ID) is characterized by global cognitive deficits, yet the very IQ tests used to assess ID have limited range and precision in this population, especially for more impaired individuals. We describe the development and validation of a method of raw z-score transformation (based on general population norms) that ameliorates floor effects and improves the precision of IQ measurement in ID using the Stanford Binet 5 (SB5) in fragile X syndrome (FXS; n = 106), the leading inherited cause of ID, and in individuals with idiopathic autism spectrum disorder (ASD; n = 205). We compared the distributional characteristics and Q-Q plots from the standardized scores with the deviation z-scores. Additionally, we examined the relationship between both scoring methods and multiple criterion measures. We found evidence that substantial and meaningful variation in cognitive ability on standardized IQ tests among individuals with ID is lost when converting raw scores to standardized scaled, index and IQ scores. Use of the deviation z- score method rectifies this problem, and accounts for significant additional variance in criterion validation measures, above and beyond the usual IQ scores. Additionally, individual and group-level cognitive strengths and weaknesses are recovered using deviation scores. Traditional methods for generating IQ scores in lower functioning individuals with ID are inaccurate and inadequate, leading to erroneously flat profiles. However assessment of cognitive abilities is substantially improved by measuring true deviation in performance from standardization sample norms. This work has important implications for standardized test development, clinical assessment, and research for which IQ is an important measure of interest in individuals with neurodevelopmental disorders and other forms of cognitive impairment.
Validation of 10 years of SAO OMI Ozone Profiles with Ozonesonde and MLS Observations
NASA Astrophysics Data System (ADS)
Huang, G.; Liu, X.; Chance, K.; Bhartia, P. K.
2015-12-01
To evaluate the accuracy and long-term stability of the SAO OMI ozone profile product, we validate ~10 years of ozone profile product (Oct. 2004-Dec. 2014) against collocated ozonesonde and MLS data. Ozone profiles as well stratospheric, tropospheric, lower tropospheric ozone columns are compared with ozonesonde data for different latitude bands, and time periods (e.g., 2004-2008/2009-2014 for without/with row anomaly. The mean biases and their standard deviations are also assessed as a function of time to evaluate the long-term stability and bias trends. In the mid-latitude and tropical regions, OMI generally shows good agreement with ozonesonde observations. The mean ozone profile biases are generally within 6% with up to 30% standard deviations. The biases of stratospheric ozone columns (SOC) and tropospheric ozone columns (TOC) are -0.3%-2.2% and -0.2%-3%, while standard deviations are 3.9%-5.8% and 14.4%-16.0%, respectively. However, the retrievals during 2009-2014 show larger standard deviations and larger temporal variations; the standard deviations increase by ~5% in the troposphere and ~2% in the stratosphere. Retrieval biases at individual levels in the stratosphere and upper troposphere show statistically significant trends and different trends for 2004-2008 and 2009-2014 periods. The trends in integrated ozone partial columns are less significant due to cancellation from various layers, except for significant trend in tropical SOC. These results suggest the need to perform time dependent radiometric calibration to maintain the long-term stability of this product. Similarly, we are comparing the OMI stratospheric ozone profiles and SOC with collocated MLS data, and the results will be reported.
Revert Ventura, A J; Sanz Requena, R; Martí-Bonmatí, L; Pallardó, Y; Jornet, J; Gaspar, C
2014-01-01
To study whether the histograms of quantitative parameters of perfusion in MRI obtained from tumor volume and peritumor volume make it possible to grade astrocytomas in vivo. We included 61 patients with histological diagnoses of grade II, III, or IV astrocytomas who underwent T2*-weighted perfusion MRI after intravenous contrast agent injection. We manually selected the tumor volume and peritumor volume and quantified the following perfusion parameters on a voxel-by-voxel basis: blood volume (BV), blood flow (BF), mean transit time (TTM), transfer constant (K(trans)), washout coefficient, interstitial volume, and vascular volume. For each volume, we obtained the corresponding histogram with its mean, standard deviation, and kurtosis (using the standard deviation and kurtosis as measures of heterogeneity) and we compared the differences in each parameter between different grades of tumor. We also calculated the mean and standard deviation of the highest 10% of values. Finally, we performed a multiparametric discriminant analysis to improve the classification. For tumor volume, we found statistically significant differences among the three grades of tumor for the means and standard deviations of BV, BF, and K(trans), both for the entire distribution and for the highest 10% of values. For the peritumor volume, we found no significant differences for any parameters. The discriminant analysis improved the classification slightly. The quantification of the volume parameters of the entire region of the tumor with BV, BF, and K(trans) is useful for grading astrocytomas. The heterogeneity represented by the standard deviation of BF is the most reliable diagnostic parameter for distinguishing between low grade and high grade lesions. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.
NASA Astrophysics Data System (ADS)
Schupp, C. A.; McNinch, J. E.; List, J. H.; Farris, A. S.
2002-12-01
The formation and behavior of hotspots, or sections of the beach that exhibit markedly higher shoreline change rates than adjacent regions, are poorly understood. Several hotspots have been identified on the Outer Banks, a developed barrier island in North Carolina. To better understand hotspot dynamics and the potential relationship to the geologic framework in which they occur, the surf zone between Duck and Bodie Island was surveyed in June 2002 as part of a research effort supported by the U.S. Geological Survey and U.S. Army Corps of Engineers. Swath bathymetry, sidescan sonar, and chirp seismic were used to characterize a region 40 km long and1 km wide. Hotspot locations were pinpointed using standard deviation values for shoreline position as determined by monthly SWASH buggy surveys of the mean high water contour between October 1999 and September 2002. Observational data and sidescan images were mapped to delineate regions of surficial sediment distributions, and regions of interest were ground-truthed via grab samples or visual inspection. General kilometer-scale correlation between acoustic backscatter and high shoreline standard deviation is evident. Acoustic returns are uniform in a region of Duck where standard deviation is low, but backscatter is patchy around the Kitty Hawk hotspot, where standard deviation is higher. Based on ground-truthing of an area further north, these patches are believed to be an older ravinement surface of fine sediment. More detailed analyses of the correlation between acoustic data, standard deviation, and hotspot locations will be presented. Future work will include integration of seismic, bathymetric, and sidescan data to better understand the links between sub-bottom geology, temporal changes in surficial sediments, surf-zone sediment budgets, and short-term changes in shoreline position and morphology.
Semen quality and alcohol intake: a systematic review and meta-analysis.
Ricci, Elena; Al Beitawi, Suha; Cipriani, Sonia; Candiani, Massimo; Chiaffarino, Francesca; Viganò, Paola; Noli, Stefania; Parazzini, Fabio
2017-01-01
Alcohol consumption is widespread in the Western world. Some studies have suggested a negative association between alcohol intake and semen quality although others have not confirmed this. MEDLINE and Embase were searched using 'alcohol intake' OR 'alcohol consumption' OR 'alcohol drinking' OR 'lifestyle' combined with 'semen quality' OR 'sperm quality' OR 'sperm volume' OR 'sperm concentration' OR 'sperm motility' for full-length observational articles, published in English. Reference lists of retrieved articles were searched for other pertinent studies. Main outcome measures were sperm parameters, if provided as means (standard deviation or standard error) or as medians (interquartile range). Fifteen cross-sectional studies were included, with 16,395 men enrolled. Main results showed that alcohol intake has a detrimental effect on semen volume (pooled estimate for no/low alcohol consumption 0.25 ml, 95% CI, 0.07 to 0.42) and normal morphology (1.87%, 95% CI, 0.86 to 2.88%). The difference was more marked when comparing occasional versus daily consumers, rather than never versus occasional, suggesting a moderate consumption did not adversely affect semen parameters. Hence, studies evaluating the effect of changes on semen parameters on the reproductive outcomes are needed in advance of providing recommendations regarding alcohol intake other than the advice to avoid heavy alcohol drinking. Copyright © 2016 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.
McFarlane, A; Aslan, B; Raby, A; Moffat, K A; Selby, R; Padmore, R
2015-12-01
Internal quality control (IQC) procedures are crucial for ensuring accurate patient test results. The IQMH Centre for Proficiency Testing conducted a web-based survey to gather information on the current IQC practices in coagulation testing. A questionnaire was distributed to 174 Ontario laboratories licensed to perform prothrombin time (PT) and activated partial thromboplastin time (APTT). All laboratories reported using two levels of commercial QC (CQC); 12% incorporate pooled patient plasma into their IQC program; >68% run CQC at the beginning of each shift; 56% following maintenance, with reagent changes, during a shift, or with every repeat sample; 6% only run CQC at the beginning of the day and 25% when the instruments have been idle for a defined period of time. IQC run frequency was determined by manufacturer recommendations (71%) but also influenced by the stability of test (27%), clinical impact of an incorrect test result (25%), and sample's batch number (10%). IQC was monitored using preset limits based on standard deviation (66%), precision goals (46%), or allowable performance limits (36%). 95% use multirules. Failure actions include repeating the IQC (90%) and reporting patient results; if repeat passes, 42% perform repeat analysis of all patient samples from last acceptable IQC. Variability exists in coagulation IQC practices among Ontario clinical laboratories. The recommendations presented here would be useful in encouraging standardized IQC practices. © 2015 John Wiley & Sons Ltd.
Veale, David; Miles, Sarah; Bramley, Sally; Muir, Gordon; Hodsoll, John
2015-06-01
To systematically review and create nomograms of flaccid and erect penile size measurements. Study key eligibility criteria: measurement of penis size by a health professional using a standard procedure; a minimum of 50 participants per sample. samples with a congenital or acquired penile abnormality, previous surgery, complaint of small penis size or erectile dysfunction. Synthesis methods: calculation of a weighted mean and pooled standard deviation (SD) and simulation of 20,000 observations from the normal distribution to generate nomograms of penis size. Nomograms for flaccid pendulous [n = 10,704, mean (SD) 9.16 (1.57) cm] and stretched length [n = 14,160, mean (SD) 13.24 (1.89) cm], erect length [n = 692, mean (SD) 13.12 (1.66) cm], flaccid circumference [n = 9407, mean (SD) 9.31 (0.90) cm], and erect circumference [n = 381, mean (SD) 11.66 (1.10) cm] were constructed. Consistent and strongest significant correlation was between flaccid stretched or erect length and height, which ranged from r = 0.2 to 0.6. relatively few erect measurements were conducted in a clinical setting and the greatest variability between studies was seen with flaccid stretched length. Penis size nomograms may be useful in clinical and therapeutic settings to counsel men and for academic research. © 2014 The Authors. BJU International © 2014 BJU International.
Liu, Jin-Ya; Chen, Li-Da; Cai, Hua-Song; Liang, Jin-Yu; Xu, Ming; Huang, Yang; Li, Wei; Feng, Shi-Ting; Xie, Xiao-Yan; Lu, Ming-De; Wang, Wei
2016-01-01
AIM: To present our initial experience regarding the feasibility of ultrasound virtual endoscopy (USVE) and its measurement reliability for polyp detection in an in vitro study using pig intestine specimens. METHODS: Six porcine intestine specimens containing 30 synthetic polyps underwent USVE, computed tomography colonography (CTC) and optical colonoscopy (OC) for polyp detection. The polyp measurement defined as the maximum polyp diameter on two-dimensional (2D) multiplanar reformatted (MPR) planes was obtained by USVE, and the absolute measurement error was analyzed using the direct measurement as the reference standard. RESULTS: USVE detected 29 (96.7%) of 30 polyps, remaining a 7-mm one missed. There was one false-positive finding. Twenty-six (89.7%) of 29 reconstructed images were clearly depicted, while 29 (96.7%) of 30 polyps were displayed on CTC with one false-negative finding. In OC, all the polyps were detected. The intraclass correlation coefficient was 0.876 (95%CI: 0.745-0.940) for measurements obtained with USVE. The pooled absolute measurement errors ± the standard deviations of the depicted polyps with actual sizes ≤ 5 mm, 6-9 mm, and ≥ 10 mm were 1.9 ± 0.8 mm, 0.9 ± 1.2 mm, and 1.0 ± 1.4 mm, respectively. CONCLUSION: USVE is reliable for polyp detection and measurement in in vitro study. PMID:27022217
Accounting Considerations in Public Sector Risk Management Pools.
ERIC Educational Resources Information Center
Commons, Harriet V.
1987-01-01
The Government Accounting Standards Board's Insurance Issues Project has issued an invitation to comment on two issues: (1) whether governmental risk pools should follow the same accounting principles as commercial insurance companies and (2) financial statement disclosures required of entities with public accountability (MLF)
Preliminary analysis of hot spot factors in an advanced reactor for space electric power systems
NASA Technical Reports Server (NTRS)
Lustig, P. H.; Holms, A. G.; Davison, H. W.
1973-01-01
The maximum fuel pin temperature for nominal operation in an advanced power reactor is 1370 K. Because of possible nitrogen embrittlement of the clad, the fuel temperature was limited to 1622 K. Assuming simultaneous occurrence of the most adverse conditions a deterministic analysis gave a maximum fuel temperature of 1610 K. A statistical analysis, using a synthesized estimate of the standard deviation for the highest fuel pin temperature, showed probabilities of 0.015 of that pin exceeding the temperature limit by the distribution free Chebyshev inequality and virtually nil assuming a normal distribution. The latter assumption gives a 1463 K maximum temperature at 3 standard deviations, the usually assumed cutoff. Further, the distribution and standard deviation of the fuel-clad gap are the most significant contributions to the uncertainty in the fuel temperature.
Influence of eye micromotions on spatially resolved refractometry
NASA Astrophysics Data System (ADS)
Chyzh, Igor H.; Sokurenko, Vyacheslav M.; Osipova, Irina Y.
2001-01-01
The influence eye micromotions on the accuracy of estimation of Zernike coefficients form eye transverse aberration measurements was investigated. By computer modeling, the following found eye aberrations have been examined: defocusing, primary astigmatism, spherical aberration of the 3rd and the 5th orders, as well as their combinations. It was determined that the standard deviation of estimated Zernike coefficients is proportional to the standard deviation of angular eye movements. Eye micromotions cause the estimation errors of Zernike coefficients of present aberrations and produce the appearance of Zernike coefficients of aberrations, absent in the eye. When solely defocusing is present, the biggest errors, cased by eye micromotions, are obtained for aberrations like coma and astigmatism. In comparison with other aberrations, spherical aberration of the 3rd and the 5th orders evokes the greatest increase of the standard deviation of other Zernike coefficients.
Barth, Nancy A.; Veilleux, Andrea G.
2012-01-01
The U.S. Geological Survey (USGS) is currently updating at-site flood frequency estimates for USGS streamflow-gaging stations in the desert region of California. The at-site flood-frequency analysis is complicated by short record lengths (less than 20 years is common) and numerous zero flows/low outliers at many sites. Estimates of the three parameters (mean, standard deviation, and skew) required for fitting the log Pearson Type 3 (LP3) distribution are likely to be highly unreliable based on the limited and heavily censored at-site data. In a generalization of the recommendations in Bulletin 17B, a regional analysis was used to develop regional estimates of all three parameters (mean, standard deviation, and skew) of the LP3 distribution. A regional skew value of zero from a previously published report was used with a new estimated mean squared error (MSE) of 0.20. A weighted least squares (WLS) regression method was used to develop both a regional standard deviation and a mean model based on annual peak-discharge data for 33 USGS stations throughout California’s desert region. At-site standard deviation and mean values were determined by using an expected moments algorithm (EMA) method for fitting the LP3 distribution to the logarithms of annual peak-discharge data. Additionally, a multiple Grubbs-Beck (MGB) test, a generalization of the test recommended in Bulletin 17B, was used for detecting multiple potentially influential low outliers in a flood series. The WLS regression found that no basin characteristics could explain the variability of standard deviation. Consequently, a constant regional standard deviation model was selected, resulting in a log-space value of 0.91 with a MSE of 0.03 log units. Yet drainage area was found to be statistically significant at explaining the site-to-site variability in mean. The linear WLS regional mean model based on drainage area had a Pseudo- 2 R of 51 percent and a MSE of 0.32 log units. The regional parameter estimates were then used to develop a set of equations for estimating flows with 50-, 20-, 10-, 4-, 2-, 1-, 0.5-, and 0.2-percent annual exceedance probabilities for ungaged basins. The final equations are functions of drainage area.Average standard errors of prediction for these regression equations range from 214.2 to 856.2 percent.
Khachatryan, Vardan
2015-08-27
A first search is reported for a standard model Higgs boson (H) that is produced through vector boson fusion and decays to a bottom-quark pair. Two data samples, corresponding to integrated luminosities of 19.8 fb -1 and 18.3 fb -1 of proton-proton collisions at √s=8 TeV were selected for this channel at the CERN LHC. The observed significance in these data samples for a H→more » $$\\mathrm{b\\bar{b}}$$ signal at a mass of 125 GeV is 2.2 standard deviations, while the expected significance is 0.8 standard deviations. The fitted signal strength μ=σ/σ SM=2.8 +1.6 -1.4. The combination of this result with other CMS searches for the Higgs boson decaying to a b-quark pair yields a signal strength of 1.0±0.4, corresponding to a signal significance of 2.6 standard deviations for a Higgs boson mass of 125 GeV.« less
Zarbo, Richard J; Copeland, Jacqueline R; Varney, Ruan C
2017-10-01
To develop a business subsystem fulfilling International Organization for Standardization 15189 nonconformance management regulatory standard, facilitating employee engagement in problem identification and resolution to effect quality improvement and risk mitigation. From 2012 to 2016, the integrated laboratories of the Henry Ford Health System used a quality technical team to develop and improve a management subsystem designed to identify, track, trend, and summarize nonconformances based on frequency, risk, and root cause for elimination at the level of the work. Programmatic improvements and training resulted in markedly increased documentation culminating in 71,641 deviations in 2016 classified by a taxonomy of 281 defect types into preanalytic (74.8%), analytic (23.6%), and postanalytic (1.6%) testing phases. The top 10 deviations accounted for 55,843 (78%) of the total. Deviation management is a key subsystem of managers' standard work whereby knowledge of nonconformities assists in directing corrective actions and continuous improvements that promote consistent execution and higher levels of performance. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
[Determination of acetochlor and oxyfluorfen by capillary gas chromatography].
Xiang, Wen-Sheng; Wang, Xiang-Jing; Wang, Jing; Wang, Qing
2002-09-01
A method is described for the determination of acetochlor and oxyfluorfen by capillary gas chromatography with FID and an SE-30 capillary column (60 m x 0.53 mm i. d., 1.5 microm), using dibutyl phthalate as the internal standard. The standard deviations for acetochlor and oxyfluorfen concentration(mass fraction) were 0.44% and 0.47% respectively. The relative standard deviations for acetochlor and oxyfluorfen were 0.79% and 0.88% and the average recoveries for acetochlor and oxyfluorfen were 99.3% and 101.1% respectively. The method is simple, rapid and accurate.
U.S. Navy Marine Climatic Atlas of the World. Volume IX. World-Wide Means and Standard Deviations
1981-10-01
TITLE (..d SobtII,) S. TYPE OF REPORT & PERIOD COVERED U. S. Navy Marine Climatic Atlas of the World Volume IX World-wide Means and Standard Reference...Ives the best estimate of the population standard deviations. The means, , are com~nuted from: EX IIN I 90 80 70 60" 50’ 40, 30 20 10 0 1070 T- VErr ...or 10%, whichever is greater Since the mean ice limit approximates the minus two de l temperature isopleth, this analyzed lower limit was Wave Heights
The normalization of deviance in healthcare delivery
Banja, John
2009-01-01
Many serious medical errors result from violations of recognized standards of practice. Over time, even egregious violations of standards of practice may become “normalized” in healthcare delivery systems. This article describes what leads to this normalization and explains why flagrant practice deviations can persist for years, despite the importance of the standards at issue. This article also provides recommendations to aid healthcare organizations in identifying and managing unsafe practice deviations before they become normalized and pose genuine risks to patient safety, quality care, and employee morale. PMID:20161685
Qualitative changes of riverine dissolved organic matter at low salinities due to flocculation
NASA Astrophysics Data System (ADS)
Asmala, Eero; Bowers, David G.; Autio, Riitta; Kaartokallio, Hermanni; Thomas, David N.
2014-10-01
The flocculation of dissolved organic matter (DOM) was studied along transects through three boreal estuaries. Besides the bulk concentration parameters, a suite of DOM quality parameters were investigated, including colored DOM (CDOM), fluorescent DOM, and the molecular weight of DOM as well as associated dissolved iron concentrations. We observed significant deviations from conservative mixing at low salinities (<2) in the estuarine samples of dissolved organic carbon (DOC), UV absorption (a(CDOM254)), and humic-like fluorescence. The maximum deviation from conservative mixing for DOC concentration was -16%, at salinities between 1 and 2. An associated laboratory experiment was conducted where an artificial salinity gradient between 0 and 6 was created. The experiment confirmed the findings from the estuarine transects, since part of the DOC and dissolved iron pools were transformed to particulate fraction (>0.2 µm) and thereby removing them from the dissolved phase. We also measured flocculation of CDOM, especially in the UV region of the absorption spectrum. Protein-like fluorescence of DOM decreased, while humic-like fluorescence increased because of salt-induced flocculation. Additionally, there was a decrease in molecular weight of DOM. Consequently, the quantity and quality of the remaining DOM pool was significantly changed after influenced to flocculation. Based on these results, we constructed a mechanistic, two-component flocculation model. Our findings underline the importance of the coastal filter, where riverine organic matter is flocculated and exported to the sediments.
Wang, Tang-Chuan; Tyler, Richard S; Chang, Ta-Yuan; Chen, Jui-Cheng; Lin, Chia-Der; Chung, Hsiung-Kwang; Tsou, Yung-An
2018-02-01
Subjective tinnitus is a phantom sensation experienced without any external source of sound that profoundly impacts the quality of life. Some investigations have claimed that transcranial direct current stimulation (tDCS) reduces tinnitus, but studies on tDCS have demonstrated variable results. This meta-analysis aimed to examine the effect of tDCS on patients with tinnitus. We searched for articles published through January 5, 2016, in Medline, Cochrane, EMBASE, and Google Scholar using the following keywords: tinnitus, transcranial direct current stimulation, and tDCS. The study outcomes were change in magnitude estimates of loudness (loudness), tinnitus-related distress (distress), and Tinnitus Handicap Inventory (THI). Pooled results demonstrated that tDCS did not have a beneficial effect on loudness (pooled standardized difference in means = 0.674, 95% CI, -0.089 to 1.437, P = .083). Further, the pooled results demonstrated a greater reduction in distress for the tDCS group (pooled standardized difference in means = 0.634, 95% CI, 0.021-1.247, P = .043). We conclude that the pooled results demonstrated a greater reduction in distress for groups treated with tDCS as compared with those administered a sham treatment.
Hoffmann, Tamara; Wensing, Annette; Brosius, Margot; Steil, Leif; Völker, Uwe
2013-01-01
Glycine betaine is an effective osmoprotectant for Bacillus subtilis. Its import into osmotically stressed cells led to the buildup of large pools, whose size was sensitively determined by the degree of the osmotic stress imposed. The amassing of glycine betaine caused repression of the formation of an osmostress-adaptive pool of proline, the only osmoprotectant that B. subtilis can synthesize de novo. The ABC transporter OpuA is the main glycine betaine uptake system of B. subtilis. Expression of opuA was upregulated in response to both sudden and sustained increases in the external osmolarity. Nonionic osmolytes exerted a stronger inducing effect on transcription than ionic osmolytes, and this was reflected in the development of corresponding OpuA-mediated glycine betaine pools. Primer extension analysis and site-directed mutagenesis pinpointed the osmotically controlled opuA promoter. Deviations from the consensus sequence of SigA-type promoters serve to keep the transcriptional activity of the opuA promoter low in the absence of osmotic stress. opuA expression was downregulated in a finely tuned manner in response to increases in the intracellular glycine betaine pool, regardless of whether this osmoprotectant was imported or was newly synthesized from choline. Such an effect was also exerted by carnitine, an effective osmoprotectant for B. subtilis that is not a substrate for the OpuA transporter. opuA expression was upregulated in a B. subtilis mutant that was unable to synthesize proline in response to osmotic stress. Collectively, our data suggest that the intracellular solute pool is a key determinant for the osmotic control of opuA expression. PMID:23175650
Observation of the Higgs boson decay to a pair of τ leptons with the CMS detector
NASA Astrophysics Data System (ADS)
Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Ambrogi, F.; Asilar, E.; Bergauer, T.; Brandstetter, J.; Brondolin, E.; Dragicevic, M.; Erö, J.; Flechl, M.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Grossmann, J.; Hrubec, J.; Jeitler, M.; König, A.; Krammer, N.; Krätschmer, I.; Liko, D.; Madlener, T.; Mikulec, I.; Pree, E.; Rabady, D.; Rad, N.; Rohringer, H.; Schieck, J.; Schöfbeck, R.; Spanring, M.; Spitzbart, D.; Waltenberger, W.; Wittmann, J.; Wulz, C.-E.; Zarucki, M.; Chekhovsky, V.; Mossolov, V.; Suarez Gonzalez, J.; De Wolf, E. A.; Di Croce, D.; Janssen, X.; Lauwers, J.; Van Haevermaet, H.; Van Mechelen, P.; Van Remortel, N.; Abu Zeid, S.; Blekman, F.; D'Hondt, J.; De Bruyn, I.; De Clercq, J.; Deroover, K.; Flouris, G.; Lontkovskyi, D.; Lowette, S.; Moortgat, S.; Moreels, L.; Python, Q.; Skovpen, K.; Tavernier, S.; Van Doninck, W.; Van Mulders, P.; Van Parijs, I.; Beghin, D.; Brun, H.; Clerbaux, B.; De Lentdecker, G.; Delannoy, H.; Fasanella, G.; Favart, L.; Goldouzian, R.; Grebenyuk, A.; Karapostoli, G.; Lenzi, T.; Luetic, J.; Maerschalk, T.; Marinov, A.; Randle-conde, A.; Seva, T.; Vander Velde, C.; Vanlaer, P.; Vannerom, D.; Yonamine, R.; Zenoni, F.; Zhang, F.; Cimmino, A.; Cornelis, T.; Dobur, D.; Fagot, A.; Gul, M.; Khvastunov, I.; Poyraz, D.; Roskas, C.; Salva, S.; Tytgat, M.; Verbeke, W.; Zaganidis, N.; Bakhshiansohi, H.; Bondu, O.; Brochet, S.; Bruno, G.; Caputo, C.; Caudron, A.; De Visscher, S.; Delaere, C.; Delcourt, M.; Francois, B.; Giammanco, A.; Jafari, A.; Komm, M.; Krintiras, G.; Lemaitre, V.; Magitteri, A.; Mertens, A.; Musich, M.; Piotrzkowski, K.; Quertenmont, L.; Vidal Marono, M.; Wertz, S.; Beliy, N.; Aldá Júnior, W. L.; Alves, F. L.; Alves, G. A.; Brito, L.; Correa Martins Junior, M.; Hensel, C.; Moraes, A.; Pol, M. E.; Rebello Teles, P.; Belchior Batista Das Chagas, E.; Carvalho, W.; Chinellato, J.; Coelho, E.; Custódio, A.; Da Costa, E. M.; Da Silveira, G. G.; De Jesus Damiao, D.; Fonseca De Souza, S.; Huertas Guativa, L. M.; Malbouisson, H.; Melo De Almeida, M.; Mora Herrera, C.; Mundim, L.; Nogima, H.; Santoro, A.; Sznajder, A.; Tonelli Manganote, E. J.; Torres Da Silva De Araujo, F.; Vilela Pereira, A.; Ahuja, S.; Bernardes, C. A.; Fernandez Perez Tomei, T. R.; Gregores, E. M.; Mercadante, P. G.; Novaes, S. F.; Padula, Sandra S.; Romero Abad, D.; Ruiz Vargas, J. C.; Aleksandrov, A.; Hadjiiska, R.; Iaydjiev, P.; Misheva, M.; Rodozov, M.; Shopova, M.; Stoykova, S.; Sultanov, G.; Dimitrov, A.; Glushkov, I.; Litov, L.; Pavlov, B.; Petkov, P.; Fang, W.; Gao, X.; Ahmad, M.; Bian, J. G.; Chen, G. M.; Chen, H. S.; Chen, M.; Chen, Y.; Jiang, C. H.; Leggat, D.; Liao, H.; Liu, Z.; Romeo, F.; Shaheen, S. M.; Spiezia, A.; Tao, J.; Wang, C.; Wang, Z.; Yazgan, E.; Zhang, H.; Zhang, S.; Zhao, J.; Ban, Y.; Chen, G.; Li, Q.; Liu, S.; Mao, Y.; Qian, S. J.; Wang, D.; Xu, Z.; Avila, C.; Cabrera, A.; Chaparro Sierra, L. F.; Florez, C.; González Hernández, C. F.; Ruiz Alvarez, J. D.; Courbon, B.; Godinovic, N.; Lelas, D.; Puljak, I.; Ribeiro Cipriano, P. M.; Sculac, T.; Antunovic, Z.; Kovac, M.; Brigljevic, V.; Ferencek, D.; Kadija, K.; Mesic, B.; Starodumov, A.; Susa, T.; Ather, M. W.; Attikis, A.; Mavromanolakis, G.; Mousa, J.; Nicolaou, C.; Ptochos, F.; Razis, P. A.; Rykaczewski, H.; Finger, M.; Finger, M.; Carrera Jarrin, E.; Assran, Y.; Elgammal, S.; Mahrous, A.; Dewanjee, R. K.; Kadastik, M.; Perrini, L.; Raidal, M.; Tiko, A.; Veelken, C.; Eerola, P.; Pekkanen, J.; Voutilainen, M.; Härkönen, J.; Järvinen, T.; Karimäki, V.; Kinnunen, R.; Lampén, T.; Lassila-Perini, K.; Lehti, S.; Lindén, T.; Luukka, P.; Tuominen, E.; Tuominiemi, J.; Tuovinen, E.; Talvitie, J.; Tuuva, T.; Besancon, M.; Couderc, F.; Dejardin, M.; Denegri, D.; Faure, J. L.; Ferri, F.; Ganjour, S.; Ghosh, S.; Givernaud, A.; Gras, P.; Hamel de Monchenault, G.; Jarry, P.; Kucher, I.; Locci, E.; Machet, M.; Malcles, J.; Negro, G.; Rander, J.; Rosowsky, A.; Sahin, M. Ö.; Titov, M.; Abdulsalam, A.; Amendola, C.; Antropov, I.; Baffioni, S.; Beaudette, F.; Busson, P.; Cadamuro, L.; Charlot, C.; Granier de Cassagnac, R.; Jo, M.; Lisniak, S.; Lobanov, A.; Martin Blanco, J.; Nguyen, M.; Ochando, C.; Ortona, G.; Paganini, P.; Pigard, P.; Salerno, R.; Sauvan, J. B.; Sirois, Y.; Stahl Leiton, A. G.; Strebler, T.; Yilmaz, Y.; Zabi, A.; Zghiche, A.; Agram, J.-L.; Andrea, J.; Bloch, D.; Brom, J.-M.; Buttignol, M.; Chabert, E. C.; Chanon, N.; Collard, C.; Conte, E.; Coubez, X.; Fontaine, J.-C.; Gelé, D.; Goerlach, U.; Jansová, M.; Le Bihan, A.-C.; Tonon, N.; Van Hove, P.; Gadrat, S.; Beauceron, S.; Bernet, C.; Boudoul, G.; Chierici, R.; Contardo, D.; Depasse, P.; El Mamouni, H.; Fay, J.; Finco, L.; Gascon, S.; Gouzevitch, M.; Grenier, G.; Ille, B.; Lagarde, F.; Laktineh, I. B.; Lethuillier, M.; Mirabito, L.; Pequegnot, A. L.; Perries, S.; Popov, A.; Sordini, V.; Vander Donckt, M.; Viret, S.; Khvedelidze, A.; Tsamalaidze, Z.; Autermann, C.; Feld, L.; Kiesel, M. K.; Klein, K.; Lipinski, M.; Preuten, M.; Schomakers, C.; Schulz, J.; Verlage, T.; Zhukov, V.; Albert, A.; Dietz-Laursonn, E.; Duchardt, D.; Endres, M.; Erdmann, M.; Erdweg, S.; Esch, T.; Fischer, R.; Güth, A.; Hamer, M.; Hebbeker, T.; Heidemann, C.; Hoepfner, K.; Knutzen, S.; Merschmeyer, M.; Meyer, A.; Millet, P.; Mukherjee, S.; Pook, T.; Radziej, M.; Reithler, H.; Rieger, M.; Scheuch, F.; Teyssier, D.; Thüer, S.; Flügge, G.; Kargoll, B.; Kress, T.; Künsken, A.; Lingemann, J.; Müller, T.; Nehrkorn, A.; Nowack, A.; Pistone, C.; Pooth, O.; Stahl, A.; Aldaya Martin, M.; Arndt, T.; Asawatangtrakuldee, C.; Beernaert, K.; Behnke, O.; Behrens, U.; Bermúdez Martínez, A.; Bin Anuar, A. A.; Borras, K.; Botta, V.; Campbell, A.; Connor, P.; Contreras-Campana, C.; Costanza, F.; Diez Pardos, C.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Eren, E.; Gallo, E.; Garay Garcia, J.; Geiser, A.; Gizhko, A.; Grados Luyando, J. M.; Grohsjean, A.; Gunnellini, P.; Guthoff, M.; Harb, A.; Hauk, J.; Hempel, M.; Jung, H.; Kalogeropoulos, A.; Kasemann, M.; Keaveney, J.; Kleinwort, C.; Korol, I.; Krücker, D.; Lange, W.; Lelek, A.; Lenz, T.; Leonard, J.; Lipka, K.; Lohmann, W.; Mankel, R.; Melzer-Pellmann, I.-A.; Meyer, A. B.; Mittag, G.; Mnich, J.; Mussgiller, A.; Ntomari, E.; Pitzl, D.; Raspereza, A.; Roland, B.; Savitskyi, M.; Saxena, P.; Shevchenko, R.; Spannagel, S.; Stefaniuk, N.; Van Onsem, G. P.; Walsh, R.; Wen, Y.; Wichmann, K.; Wissing, C.; Zenaiev, O.; Bein, S.; Blobel, V.; Centis Vignali, M.; Dreyer, T.; Garutti, E.; Gonzalez, D.; Haller, J.; Hinzmann, A.; Hoffmann, M.; Karavdina, A.; Klanner, R.; Kogler, R.; Kovalchuk, N.; Kurz, S.; Lapsien, T.; Marchesini, I.; Marconi, D.; Meyer, M.; Niedziela, M.; Nowatschin, D.; Pantaleo, F.; Peiffer, T.; Perieanu, A.; Scharf, C.; Schleper, P.; Schmidt, A.; Schumann, S.; Schwandt, J.; Sonneveld, J.; Stadie, H.; Steinbrück, G.; Stober, F. M.; Stöver, M.; Tholen, H.; Troendle, D.; Usai, E.; Vanelderen, L.; Vanhoefer, A.; Vormwald, B.; Akbiyik, M.; Barth, C.; Baur, S.; Butz, E.; Caspart, R.; Chwalek, T.; Colombo, F.; De Boer, W.; Dierlamm, A.; Freund, B.; Friese, R.; Giffels, M.; Haitz, D.; Hartmann, F.; Heindl, S. M.; Husemann, U.; Kassel, F.; Kudella, S.; Mildner, H.; Mozer, M. U.; Müller, Th.; Plagge, M.; Quast, G.; Rabbertz, K.; Schröder, M.; Shvetsov, I.; Sieber, G.; Simonis, H. J.; Ulrich, R.; Wayand, S.; Weber, M.; Weiler, T.; Williamson, S.; Wöhrmann, C.; Wolf, R.; Anagnostou, G.; Daskalakis, G.; Geralis, T.; Giakoumopoulou, V. A.; Kyriakis, A.; Loukas, D.; Topsis-Giotis, I.; Karathanasis, G.; Kesisoglou, S.; Panagiotou, A.; Saoulidou, N.; Kousouris, K.; Evangelou, I.; Foudas, C.; Kokkas, P.; Mallios, S.; Manthos, N.; Papadopoulos, I.; Paradas, E.; Strologas, J.; Triantis, F. A.; Csanad, M.; Filipovic, N.; Pasztor, G.; Veres, G. I.; Bencze, G.; Hajdu, C.; Horvath, D.; Hunyadi, Á.; Sikler, F.; Veszpremi, V.; Zsigmond, A. J.; Beni, N.; Czellar, S.; Karancsi, J.; Makovec, A.; Molnar, J.; Szillasi, Z.; Bartók, M.; Raics, P.; Trocsanyi, Z. L.; Ujvari, B.; Choudhury, S.; Komaragiri, J. R.; Bahinipati, S.; Bhowmik, S.; Mal, P.; Mandal, K.; Nayak, A.; Sahoo, D. K.; Sahoo, N.; Swain, S. K.; Bansal, S.; Beri, S. B.; Bhatnagar, V.; Chawla, R.; Dhingra, N.; Kalsi, A. K.; Kaur, A.; Kaur, M.; Kumar, R.; Kumari, P.; Mehta, A.; Singh, J. B.; Walia, G.; Kumar, Ashok; Shah, Aashaq; Bhardwaj, A.; Chauhan, S.; Choudhary, B. C.; Garg, R. B.; Keshri, S.; Kumar, A.; Malhotra, S.; Naimuddin, M.; Ranjan, K.; Sharma, R.; Bhardwaj, R.; Bhattacharya, R.; Bhattacharya, S.; Bhawandeep, U.; Dey, S.; Dutt, S.; Dutta, S.; Ghosh, S.; Majumdar, N.; Modak, A.; Mondal, K.; Mukhopadhyay, S.; Nandan, S.; Purohit, A.; Roy, A.; Roy, D.; Roy Chowdhury, S.; Sarkar, S.; Sharan, M.; Thakur, S.; Behera, P. K.; Chudasama, R.; Dutta, D.; Jha, V.; Kumar, V.; Mohanty, A. K.; Netrakanti, P. K.; Pant, L. M.; Shukla, P.; Topkar, A.; Aziz, T.; Dugad, S.; Mahakud, B.; Mitra, S.; Mohanty, G. B.; Sur, N.; Sutar, B.; Banerjee, S.; Bhattacharya, S.; Chatterjee, S.; Das, P.; Guchait, M.; Jain, Sa.; Kumar, S.; Maity, M.; Majumder, G.; Mazumdar, K.; Sarkar, T.; Wickramage, N.; Chauhan, S.; Dube, S.; Hegde, V.; Kapoor, A.; Kothekar, K.; Pandey, S.; Rane, A.; Sharma, S.; Chenarani, S.; Eskandari Tadavani, E.; Etesami, S. M.; Khakzad, M.; Mohammadi Najafabadi, M.; Naseri, M.; Paktinat Mehdiabadi, S.; Rezaei Hosseinabadi, F.; Safarzadeh, B.; Zeinali, M.; Felcini, M.; Grunewald, M.; Abbrescia, M.; Calabria, C.; Colaleo, A.; Creanza, D.; Cristella, L.; De Filippis, N.; De Palma, M.; Errico, F.; Fiore, L.; Iaselli, G.; Lezki, S.; Maggi, G.; Maggi, M.; Miniello, G.; My, S.; Nuzzo, S.; Pompili, A.; Pugliese, G.; Radogna, R.; Ranieri, A.; Selvaggi, G.; Sharma, A.; Silvestris, L.; Venditti, R.; Verwilligen, P.; Abbiendi, G.; Battilana, C.; Bonacorsi, D.; Braibant-Giacomelli, S.; Campanini, R.; Capiluppi, P.; Castro, A.; Cavallo, F. R.; Chhibra, S. S.; Codispoti, G.; Cuffiani, M.; Dallavalle, G. M.; Fabbri, F.; Fanfani, A.; Fasanella, D.; Giacomelli, P.; Grandi, C.; Guiducci, L.; Marcellini, S.; Masetti, G.; Montanari, A.; Navarria, F. L.; Perrotta, A.; Rossi, A. M.; Rovelli, T.; Siroli, G. P.; Tosi, N.; Albergo, S.; Costa, S.; Di Mattia, A.; Giordano, F.; Potenza, R.; Tricomi, A.; Tuve, C.; Barbagli, G.; Chatterjee, K.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Lenzi, P.; Meschini, M.; Paoletti, S.; Russo, L.; Sguazzoni, G.; Strom, D.; Viliani, L.; Benussi, L.; Bianco, S.; Fabbri, F.; Piccolo, D.; Primavera, F.; Calvelli, V.; Ferro, F.; Robutti, E.; Tosi, S.; Benaglia, A.; Brianza, L.; Brivio, F.; Ciriolo, V.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Ghezzi, A.; Govoni, P.; Malberti, M.; Malvezzi, S.; Manzoni, R. A.; Menasce, D.; Moroni, L.; Paganoni, M.; Pauwels, K.; Pedrini, D.; Pigazzini, S.; Ragazzi, S.; Redaelli, N.; Tabarelli de Fatis, T.; Buontempo, S.; Cavallo, N.; Di Guida, S.; Fabozzi, F.; Fienga, F.; Iorio, A. O. M.; Khan, W. A.; Lista, L.; Meola, S.; Paolucci, P.; Sciacca, C.; Thyssen, F.; Azzi, P.; Bacchetta, N.; Benato, L.; Bisello, D.; Boletti, A.; Bragagnolo, A.; Carlin, R.; Carvalho Antunes De Oliveira, A.; Checchia, P.; Dall'Osso, M.; De Castro Manzano, P.; Dorigo, T.; Dosselli, U.; Gasparini, F.; Gasparini, U.; Lacaprara, S.; Lujan, P.; Margoni, M.; Meneguzzo, A. T.; Pozzobon, N.; Ronchese, P.; Rossin, R.; Simonetto, F.; Torassa, E.; Ventura, S.; Zanetti, M.; Zotto, P.; Braghieri, A.; Magnani, A.; Montagna, P.; Ratti, S. P.; Re, V.; Ressegotti, M.; Riccardi, C.; Salvini, P.; Vai, I.; Vitulo, P.; Alunni Solestizi, L.; Biasini, M.; Bilei, G. M.; Cecchi, C.; Ciangottini, D.; Fanò, L.; Lariccia, P.; Leonardi, R.; Manoni, E.; Mantovani, G.; Mariani, V.; Menichelli, M.; Rossi, A.; Santocchia, A.; Spiga, D.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Boccali, T.; Borrello, L.; Castaldi, R.; Ciocci, M. A.; Dell'Orso, R.; Fedi, G.; Giannini, L.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Manca, E.; Mandorli, G.; Martini, L.; Messineo, A.; Palla, F.; Rizzi, A.; Savoy-Navarro, A.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Barone, L.; Cavallari, F.; Cipriani, M.; Daci, N.; Del Re, D.; Di Marco, E.; Diemoz, M.; Gelli, S.; Longo, E.; Margaroli, F.; Marzocchi, B.; Meridiani, P.; Organtini, G.; Paramatti, R.; Preiato, F.; Rahatlou, S.; Rovelli, C.; Santanastasio, F.; Amapane, N.; Arcidiacono, R.; Argiro, S.; Arneodo, M.; Bartosik, N.; Bellan, R.; Biino, C.; Cartiglia, N.; Cenna, F.; Costa, M.; Covarelli, R.; Degano, A.; Demaria, N.; Kiani, B.; Mariotti, C.; Maselli, S.; Migliore, E.; Monaco, V.; Monteil, E.; Monteno, M.; Obertino, M. M.; Pacher, L.; Pastrone, N.; Pelliccioni, M.; Pinna Angioni, G. L.; Ravera, F.; Romero, A.; Ruspa, M.; Sacchi, R.; Shchelina, K.; Sola, V.; Solano, A.; Staiano, A.; Traczyk, P.; Belforte, S.; Casarsa, M.; Cossutti, F.; Della Ricca, G.; Zanetti, A.; Kim, D. H.; Kim, G. N.; Kim, M. S.; Lee, J.; Lee, S.; Lee, S. W.; Moon, C. S.; Oh, Y. D.; Sekmen, S.; Son, D. C.; Yang, Y. C.; Lee, A.; Kim, H.; Moon, D. H.; Oh, G.; Brochero Cifuentes, J. A.; Goh, J.; Kim, T. J.; Cho, S.; Choi, S.; Go, Y.; Gyun, D.; Ha, S.; Hong, B.; Jo, Y.; Kim, Y.; Lee, K.; Lee, K. S.; Lee, S.; Lim, J.; Park, S. K.; Roh, Y.; Almond, J.; Kim, J.; Kim, J. S.; Lee, H.; Lee, K.; Nam, K.; Oh, S. B.; Radburn-Smith, B. C.; Seo, S. h.; Yang, U. K.; Yoo, H. D.; Yu, G. B.; Choi, M.; Kim, H.; Kim, J. H.; Lee, J. S. H.; Park, I. C.; Choi, Y.; Hwang, C.; Lee, J.; Yu, I.; Dudenas, V.; Juodagalvis, A.; Vaitkus, J.; Ahmed, I.; Ibrahim, Z. A.; Md Ali, M. A. B.; Mohamad Idris, F.; Wan Abdullah, W. A. T.; Yusli, M. N.; Zolkapli, Z.; Reyes-Almanza, R.; Ramirez-Sanchez, G.; Duran-Osuna, M. C.; Castilla-Valdez, H.; De La Cruz-Burelo, E.; Heredia-De La Cruz, I.; Rabadan-Trejo, R. I.; Lopez-Fernandez, R.; Mejia Guisao, J.; Sanchez-Hernandez, A.; Carrillo Moreno, S.; Oropeza Barrera, C.; Vazquez Valencia, F.; Pedraza, I.; Salazar Ibarguen, H. A.; Uribe Estrada, C.; Morelos Pineda, A.; Krofcheck, D.; Butler, P. H.; Ahmad, A.; Ahmad, M.; Hassan, Q.; Hoorani, H. R.; Saddique, A.; Shah, M. A.; Shoaib, M.; Waqas, M.; Bialkowska, H.; Bluj, M.; Boimska, B.; Frueboes, T.; Górski, M.; Kazana, M.; Nawrocki, K.; Szleper, M.; Zalewski, P.; Bunkowski, K.; Byszuk, A.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Misiura, M.; Olszewski, M.; Pyskir, A.; Walczak, M.; Bargassa, P.; Beirão Da Cruz E Silva, C.; Di Francesco, A.; Faccioli, P.; Galinhas, B.; Gallinaro, M.; Hollar, J.; Leonardo, N.; Lloret Iglesias, L.; Nemallapudi, M. V.; Seixas, J.; Strong, G.; Toldaiev, O.; Vadruccio, D.; Varela, J.; Afanasiev, S.; Bunin, P.; Gavrilenko, M.; Golutvin, I.; Gorbunov, I.; Kamenev, A.; Karjavin, V.; Lanev, A.; Malakhov, A.; Matveev, V.; Palichik, V.; Perelygin, V.; Shmatov, S.; Shulha, S.; Skatchkov, N.; Smirnov, V.; Voytishin, N.; Zarubin, A.; Ivanov, Y.; Kim, V.; Kuznetsova, E.; Levchenko, P.; Murzin, V.; Oreshkin, V.; Smirnov, I.; Sulimov, V.; Uvarov, L.; Vavilov, S.; Vorobyev, A.; Andreev, Yu.; Dermenev, A.; Gninenko, S.; Golubev, N.; Karneyeu, A.; Kirsanov, M.; Krasnikov, N.; Pashenkov, A.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Spiridonov, A.; Stepennov, A.; Toms, M.; Vlasov, E.; Zhokin, A.; Aushev, T.; Bylinkin, A.; Chadeeva, M.; Parygin, P.; Philippov, D.; Polikarpov, S.; Popova, E.; Rusinov, V.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Terkulov, A.; Baskakov, A.; Belyaev, A.; Boos, E.; Bunichev, V.; Dubinin, M.; Dudko, L.; Ershov, A.; Gribushin, A.; Klyukhin, V.; Kodolova, O.; Lokhtin, I.; Miagkov, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Blinov, V.; Skovpen, Y.; Shtol, D.; Azhgirey, I.; Bayshev, I.; Bitioukov, S.; Elumakhov, D.; Kachanov, V.; Kalinin, A.; Konstantinov, D.; Petrov, V.; Ryutin, R.; Sobol, A.; Troshin, S.; Tyurin, N.; Uzunian, A.; Volkov, A.; Adzic, P.; Cirkovic, P.; Devetak, D.; Dordevic, M.; Milosevic, J.; Rekovic, V.; Alcaraz Maestre, J.; Barrio Luna, M.; Cerrada, M.; Colino, N.; De La Cruz, B.; Delgado Peris, A.; Escalante Del Valle, A.; Fernandez Bedoya, C.; Fernández Ramos, J. P.; Flix, J.; Fouz, M. C.; Garcia-Abia, P.; Gonzalez Lopez, O.; Goy Lopez, S.; Hernandez, J. M.; Josa, M. I.; Moran, D.; Pérez-Calero Yzquierdo, A.; Puerta Pelayo, J.; Quintario Olmeda, A.; Redondo, I.; Romero, L.; Soares, M. S.; Álvarez Fernández, A.; de Trocóniz, J. F.; Missiroli, M.; Cuevas, J.; Erice, C.; Fernandez Menendez, J.; Gonzalez Caballero, I.; González Fernández, J. R.; Palencia Cortezon, E.; Sanchez Cruz, S.; Vischia, P.; Vizan Garcia, J. M.; Cabrillo, I. J.; Calderon, A.; Chazin Quero, B.; Curras, E.; Duarte Campderros, J.; Fernandez, M.; Garcia-Ferrero, J.; Gomez, G.; Lopez Virto, A.; Marco, J.; Martinez Rivero, C.; Martinez Ruiz del Arbol, P.; Matorras, F.; Piedra Gomez, J.; Rodrigo, T.; Ruiz-Jimeno, A.; Scodellaro, L.; Trevisani, N.; Vila, I.; Vilar Cortabitarte, R.; Abbaneo, D.; Auffray, E.; Baillon, P.; Ball, A. H.; Barney, D.; Bianco, M.; Bloch, P.; Bocci, A.; Botta, C.; Camporesi, T.; Castello, R.; Cepeda, M.; Cerminara, G.; Chapon, E.; Chen, Y.; d'Enterria, D.; Dabrowski, A.; Daponte, V.; David, A.; De Gruttola, M.; De Roeck, A.; Dobson, M.; Dorney, B.; du Pree, T.; Dünser, M.; Dupont, N.; Elliott-Peisert, A.; Everaerts, P.; Fallavollita, F.; Franzoni, G.; Fulcher, J.; Funk, W.; Gigi, D.; Gilbert, A.; Gill, K.; Glege, F.; Gulhan, D.; Harris, P.; Hegeman, J.; Innocente, V.; Janot, P.; Karacheban, O.; Kieseler, J.; Kirschenmann, H.; Knünz, V.; Kornmayer, A.; Kortelainen, M. J.; Krammer, M.; Lange, C.; Lecoq, P.; Lourenço, C.; Lucchini, M. T.; Malgeri, L.; Mannelli, M.; Martelli, A.; Meijers, F.; Merlin, J. A.; Mersi, S.; Meschi, E.; Milenovic, P.; Moortgat, F.; Mulders, M.; Neugebauer, H.; Ngadiuba, J.; Orfanelli, S.; Orsini, L.; Pape, L.; Perez, E.; Peruzzi, M.; Petrilli, A.; Petrucciani, G.; Pfeiffer, A.; Pierini, M.; Racz, A.; Reis, T.; Rolandi, G.; Rovere, M.; Sakulin, H.; Schäfer, C.; Schwick, C.; Seidel, M.; Selvaggi, M.; Sharma, A.; Silva, P.; Sphicas, P.; Stakia, A.; Steggemann, J.; Stoye, M.; Tosi, M.; Treille, D.; Triossi, A.; Tsirou, A.; Veckalns, V.; Verweij, M.; Zeuner, W. D.; Bertl, W.; Caminada, L.; Deiters, K.; Erdmann, W.; Horisberger, R.; Ingram, Q.; Kaestli, H. C.; Kotlinski, D.; Langenegger, U.; Rohe, T.; Wiederkehr, S. A.; Bäni, L.; Berger, P.; Bianchini, L.; Casal, B.; Dissertori, G.; Dittmar, M.; Donegà, M.; Grab, C.; Heidegger, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Klijnsma, T.; Lustermann, W.; Mangano, B.; Marionneau, M.; Meinhard, M. T.; Meister, D.; Micheli, F.; Musella, P.; Nessi-Tedaldi, F.; Pandolfi, F.; Pata, J.; Pauss, F.; Perrin, G.; Perrozzi, L.; Quittnat, M.; Reichmann, M.; Schönenberger, M.; Shchutska, L.; Tavolaro, V. R.; Theofilatos, K.; Vesterbacka Olsson, M. L.; Wallny, R.; Zhu, D. H.; Aarrestad, T. K.; Amsler, C.; Canelli, M. F.; De Cosa, A.; Del Burgo, R.; Donato, S.; Galloni, C.; Hreus, T.; Kilminster, B.; Pinna, D.; Rauco, G.; Robmann, P.; Salerno, D.; Seitz, C.; Takahashi, Y.; Zucchetta, A.; Candelise, V.; Doan, T. H.; Jain, Sh.; Khurana, R.; Kuo, C. M.; Lin, W.; Pozdnyakov, A.; Yu, S. S.; Kumar, Arun; Chang, P.; Chao, Y.; Chen, K. F.; Chen, P. H.; Fiori, F.; Hsiung, Y.; Liu, Y. F.; Lu, R.-S.; Paganis, E.; Psallidas, A.; Steen, A.; Tsai, J. f.; Asavapibhop, B.; Kovitanggoon, K.; Singh, G.; Srimanobhas, N.; Boran, F.; Cerci, S.; Damarseckin, S.; Demiroglu, Z. S.; Dozen, C.; Dumanoglu, I.; Girgis, S.; Gokbulut, G.; Guler, Y.; Hos, I.; Kangal, E. E.; Kara, O.; Kayis Topaksu, A.; Kiminsu, U.; Oglakci, M.; Onengut, G.; Ozdemir, K.; Sunar Cerci, D.; Tali, B.; Turkcapar, S.; Zorbakir, I. S.; Zorbilmez, C.; Bilin, B.; Karapinar, G.; Ocalan, K.; Yalvac, M.; Zeyrek, M.; Gülmez, E.; Kaya, M.; Kaya, O.; Tekten, S.; Yetkin, E. A.; Agaras, M. N.; Atay, S.; Cakir, A.; Cankocak, K.; Grynyov, B.; Levchuk, L.; Aggleton, R.; Ball, F.; Beck, L.; Brooke, J. J.; Burns, D.; Clement, E.; Cussans, D.; Davignon, O.; Flacher, H.; Goldstein, J.; Grimes, M.; Heath, G. P.; Heath, H. F.; Jacob, J.; Kreczko, L.; Lucas, C.; Newbold, D. M.; Paramesvaran, S.; Poll, A.; Sakuma, T.; Seif El Nasr-storey, S.; Smith, D.; Smith, V. J.; Bell, K. W.; Belyaev, A.; Brew, C.; Brown, R. M.; Calligaris, L.; Cieri, D.; Cockerill, D. J. A.; Coughlan, J. A.; Harder, K.; Harper, S.; Olaiya, E.; Petyt, D.; Shepherd-Themistocleous, C. H.; Thea, A.; Tomalin, I. R.; Williams, T.; Auzinger, G.; Bainbridge, R.; Borg, J.; Breeze, S.; Buchmuller, O.; Bundock, A.; Casasso, S.; Citron, M.; Colling, D.; Corpe, L.; Dauncey, P.; Davies, G.; De Wit, A.; Della Negra, M.; Di Maria, R.; Elwood, A.; Haddad, Y.; Hall, G.; Iles, G.; James, T.; Lane, R.; Laner, C.; Lyons, L.; Magnan, A.-M.; Malik, S.; Mastrolorenzo, L.; Matsushita, T.; Nash, J.; Nikitenko, A.; Palladino, V.; Pesaresi, M.; Raymond, D. M.; Richards, A.; Rose, A.; Scott, E.; Seez, C.; Shtipliyski, A.; Summers, S.; Tapper, A.; Uchida, K.; Vazquez Acosta, M.; Virdee, T.; Wardle, N.; Winterbottom, D.; Wright, J.; Zenz, S. C.; Cole, J. E.; Hobson, P. R.; Khan, A.; Kyberd, P.; Reid, I. D.; Symonds, P.; Teodorescu, L.; Turner, M.; Borzou, A.; Call, K.; Dittmann, J.; Hatakeyama, K.; Liu, H.; Pastika, N.; Smith, C.; Bartek, R.; Dominguez, A.; Buccilli, A.; Cooper, S. I.; Henderson, C.; Rumerio, P.; West, C.; Arcaro, D.; Avetisyan, A.; Bose, T.; Gastler, D.; Rankin, D.; Richardson, C.; Rohlf, J.; Sulak, L.; Zou, D.; Benelli, G.; Cutts, D.; Garabedian, A.; Hakala, J.; Heintz, U.; Hogan, J. M.; Kwok, K. H. M.; Laird, E.; Landsberg, G.; Mao, Z.; Narain, M.; Pazzini, J.; Piperov, S.; Sagir, S.; Syarif, R.; Yu, D.; Band, R.; Brainerd, C.; Burns, D.; Calderon De La Barca Sanchez, M.; Chertok, M.; Conway, J.; Conway, R.; Cox, P. T.; Erbacher, R.; Flores, C.; Funk, G.; Gardner, M.; Ko, W.; Lander, R.; Mclean, C.; Mulhearn, M.; Pellett, D.; Pilot, J.; Shalhout, S.; Shi, M.; Smith, J.; Stolp, D.; Tos, K.; Tripathi, M.; Wang, Z.; Bachtis, M.; Bravo, C.; Cousins, R.; Dasgupta, A.; Florent, A.; Hauser, J.; Ignatenko, M.; Mccoll, N.; Regnard, S.; Saltzberg, D.; Schnaible, C.; Valuev, V.; Bouvier, E.; Burt, K.; Clare, R.; Ellison, J.; Gary, J. W.; Ghiasi Shirazi, S. M. A.; Hanson, G.; Heilman, J.; Jandir, P.; Kennedy, E.; Lacroix, F.; Long, O. R.; Olmedo Negrete, M.; Paneva, M. I.; Shrinivas, A.; Si, W.; Wang, L.; Wei, H.; Wimpenny, S.; Yates, B. R.; Branson, J. G.; Cittolin, S.; Derdzinski, M.; Gerosa, R.; Hashemi, B.; Holzner, A.; Klein, D.; Kole, G.; Krutelyov, V.; Letts, J.; Macneill, I.; Masciovecchio, M.; Olivito, D.; Padhi, S.; Pieri, M.; Sani, M.; Sharma, V.; Simon, S.; Tadel, M.; Vartak, A.; Wasserbaech, S.; Wood, J.; Würthwein, F.; Yagil, A.; Zevi Della Porta, G.; Amin, N.; Bhandari, R.; Bradmiller-Feld, J.; Campagnari, C.; Dishaw, A.; Dutta, V.; Franco Sevilla, M.; George, C.; Golf, F.; Gouskos, L.; Gran, J.; Heller, R.; Incandela, J.; Mullin, S. D.; Ovcharova, A.; Qu, H.; Richman, J.; Stuart, D.; Suarez, I.; Yoo, J.; Anderson, D.; Bendavid, J.; Bornheim, A.; Lawhorn, J. M.; Newman, H. B.; Nguyen, T.; Pena, C.; Spiropulu, M.; Vlimant, J. R.; Xie, S.; Zhang, Z.; Zhu, R. Y.; Andrews, M. B.; Ferguson, T.; Mudholkar, T.; Paulini, M.; Russ, J.; Sun, M.; Vogel, H.; Vorobiev, I.; Weinberg, M.; Cumalat, J. P.; Ford, W. T.; Jensen, F.; Johnson, A.; Krohn, M.; Leontsinis, S.; Mulholland, T.; Stenson, K.; Wagner, S. R.; Alexander, J.; Chaves, J.; Chu, J.; Dittmer, S.; Mcdermott, K.; Mirman, N.; Patterson, J. R.; Rinkevicius, A.; Ryd, A.; Skinnari, L.; Soffi, L.; Tan, S. M.; Tao, Z.; Thom, J.; Tucker, J.; Wittich, P.; Zientek, M.; Abdullin, S.; Albrow, M.; Alyari, M.; Apollinari, G.; Apresyan, A.; Apyan, A.; Banerjee, S.; Bauerdick, L. A. T.; Beretvas, A.; Berryhill, J.; Bhat, P. C.; Bolla, G.; Burkett, K.; Butler, J. N.; Canepa, A.; Cerati, G. B.; Cheung, H. W. K.; Chlebana, F.; Cremonesi, M.; Duarte, J.; Elvira, V. D.; Freeman, J.; Gecse, Z.; Gottschalk, E.; Gray, L.; Green, D.; Grünendahl, S.; Gutsche, O.; Harris, R. M.; Hasegawa, S.; Hirschauer, J.; Hu, Z.; Jayatilaka, B.; Jindariani, S.; Johnson, M.; Joshi, U.; Klima, B.; Kreis, B.; Lammel, S.; Lincoln, D.; Lipton, R.; Liu, M.; Liu, T.; Lopes De Sá, R.; Lykken, J.; Maeshima, K.; Magini, N.; Marraffino, J. M.; Maruyama, S.; Mason, D.; McBride, P.; Merkel, P.; Mrenna, S.; Nahn, S.; O'Dell, V.; Pedro, K.; Prokofyev, O.; Rakness, G.; Ristori, L.; Schneider, B.; Sexton-Kennedy, E.; Soha, A.; Spalding, W. J.; Spiegel, L.; Stoynev, S.; Strait, J.; Strobbe, N.; Taylor, L.; Tkaczyk, S.; Tran, N. V.; Uplegger, L.; Vaandering, E. W.; Vernieri, C.; Verzocchi, M.; Vidal, R.; Wang, M.; Weber, H. A.; Whitbeck, A.; Acosta, D.; Avery, P.; Bortignon, P.; Bourilkov, D.; Brinkerhoff, A.; Carnes, A.; Carver, M.; Curry, D.; Field, R. D.; Furic, I. K.; Konigsberg, J.; Korytov, A.; Kotov, K.; Ma, P.; Matchev, K.; Mei, H.; Mitselmakher, G.; Rank, D.; Sperka, D.; Terentyev, N.; Thomas, L.; Wang, J.; Wang, S.; Yelton, J.; Joshi, Y. R.; Linn, S.; Markowitz, P.; Rodriguez, J. L.; Ackert, A.; Adams, T.; Askew, A.; Hagopian, S.; Hagopian, V.; Johnson, K. F.; Kolberg, T.; Martinez, G.; Perry, T.; Prosper, H.; Saha, A.; Santra, A.; Sharma, V.; Yohay, R.; Baarmand, M. M.; Bhopatkar, V.; Colafranceschi, S.; Hohlmann, M.; Noonan, D.; Roy, T.; Yumiceva, F.; Adams, M. R.; Apanasevich, L.; Berry, D.; Betts, R. R.; Cavanaugh, R.; Chen, X.; Evdokimov, O.; Gerber, C. E.; Hangal, D. A.; Hofman, D. J.; Jung, K.; Kamin, J.; Sandoval Gonzalez, I. D.; Tonjes, M. B.; Trauger, H.; Varelas, N.; Wang, H.; Wu, Z.; Zhang, J.; Bilki, B.; Clarida, W.; Dilsiz, K.; Durgut, S.; Gandrajula, R. P.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Snyder, C.; Tiras, E.; Wetzel, J.; Yi, K.; Blumenfeld, B.; Cocoros, A.; Eminizer, N.; Fehling, D.; Feng, L.; Gritsan, A. V.; Maksimovic, P.; Roskes, J.; Sarica, U.; Swartz, M.; Xiao, M.; You, C.; Al-bataineh, A.; Baringer, P.; Bean, A.; Boren, S.; Bowen, J.; Castle, J.; Khalil, S.; Kropivnitskaya, A.; Majumder, D.; Mcbrayer, W.; Murray, M.; Royon, C.; Sanders, S.; Schmitz, E.; Tapia Takaki, J. D.; Wang, Q.; Ivanov, A.; Kaadze, K.; Maravin, Y.; Mohammadi, A.; Saini, L. K.; Skhirtladze, N.; Toda, S.; Rebassoo, F.; Wright, D.; Anelli, C.; Baden, A.; Baron, O.; Belloni, A.; Calvert, B.; Eno, S. C.; Ferraioli, C.; Hadley, N. J.; Jabeen, S.; Jeng, G. Y.; Kellogg, R. G.; Kunkle, J.; Mignerey, A. C.; Ricci-Tam, F.; Shin, Y. H.; Skuja, A.; Tonwar, S. C.; Abercrombie, D.; Allen, B.; Azzolini, V.; Barbieri, R.; Baty, A.; Bi, R.; Brandt, S.; Busza, W.; Cali, I. A.; D'Alfonso, M.; Demiragli, Z.; Gomez Ceballos, G.; Goncharov, M.; Hsu, D.; Iiyama, Y.; Innocenti, G. M.; Klute, M.; Kovalskyi, D.; Lai, Y. S.; Lee, Y.-J.; Levin, A.; Luckey, P. D.; Maier, B.; Marini, A. C.; Mcginn, C.; Mironov, C.; Narayanan, S.; Niu, X.; Paus, C.; Roland, C.; Roland, G.; Salfeld-Nebgen, J.; Stephans, G. S. F.; Tatar, K.; Velicanu, D.; Wang, J.; Wang, T. W.; Wyslouch, B.; Benvenuti, A. C.; Chatterjee, R. M.; Evans, A.; Hansen, P.; Kalafut, S.; Kubota, Y.; Lesko, Z.; Mans, J.; Nourbakhsh, S.; Ruckstuhl, N.; Rusack, R.; Turkewitz, J.; Acosta, J. G.; Oliveros, S.; Avdeeva, E.; Bloom, K.; Claes, D. R.; Fangmeier, C.; Gonzalez Suarez, R.; Kamalieddin, R.; Kravchenko, I.; Monroy, J.; Siado, J. E.; Snow, G. R.; Stieger, B.; Dolen, J.; Godshalk, A.; Harrington, C.; Iashvili, I.; Nguyen, D.; Parker, A.; Rappoccio, S.; Roozbahani, B.; Alverson, G.; Barberis, E.; Hortiangtham, A.; Massironi, A.; Morse, D. M.; Nash, D.; Orimoto, T.; Teixeira De Lima, R.; Trocino, D.; Wood, D.; Bhattacharya, S.; Charaf, O.; Hahn, K. A.; Mucia, N.; Odell, N.; Pollack, B.; Schmitt, M. H.; Sung, K.; Trovato, M.; Velasco, M.; Dev, N.; Hildreth, M.; Hurtado Anampa, K.; Jessop, C.; Karmgard, D. J.; Kellams, N.; Lannon, K.; Loukas, N.; Marinelli, N.; Meng, F.; Mueller, C.; Musienko, Y.; Planer, M.; Reinsvold, A.; Ruchti, R.; Smith, G.; Taroni, S.; Wayne, M.; Wolf, M.; Woodard, A.; Alimena, J.; Antonelli, L.; Bylsma, B.; Durkin, L. S.; Flowers, S.; Francis, B.; Hart, A.; Hill, C.; Ji, W.; Liu, B.; Luo, W.; Puigh, D.; Winer, B. L.; Wulsin, H. W.; Cooperstein, S.; Driga, O.; Elmer, P.; Hardenbrook, J.; Hebda, P.; Higginbotham, S.; Lange, D.; Luo, J.; Marlow, D.; Mei, K.; Ojalvo, I.; Olsen, J.; Palmer, C.; Piroué, P.; Stickland, D.; Tully, C.; Malik, S.; Norberg, S.; Barker, A.; Barnes, V. E.; Das, S.; Folgueras, S.; Gutay, L.; Jha, M. K.; Jones, M.; Jung, A. W.; Khatiwada, A.; Miller, D. H.; Neumeister, N.; Peng, C. C.; Schulte, J. F.; Sun, J.; Wang, F.; Xie, W.; Cheng, T.; Parashar, N.; Stupak, J.; Adair, A.; Akgun, B.; Chen, Z.; Ecklund, K. M.; Geurts, F. J. M.; Guilbaud, M.; Li, W.; Michlin, B.; Northup, M.; Padley, B. P.; Roberts, J.; Rorie, J.; Tu, Z.; Zabel, J.; Bodek, A.; de Barbaro, P.; Demina, R.; Duh, Y. t.; Ferbel, T.; Galanti, M.; Garcia-Bellido, A.; Han, J.; Hindrichs, O.; Khukhunaishvili, A.; Lo, K. H.; Tan, P.; Verzetti, M.; Ciesielski, R.; Goulianos, K.; Mesropian, C.; Agapitos, A.; Chou, J. P.; Gershtein, Y.; Gómez Espinosa, T. A.; Halkiadakis, E.; Heindl, M.; Hughes, E.; Kaplan, S.; Kunnawalkam Elayavalli, R.; Kyriacou, S.; Lath, A.; Montalvo, R.; Nash, K.; Osherson, M.; Saka, H.; Salur, S.; Schnetzer, S.; Sheffield, D.; Somalwar, S.; Stone, R.; Thomas, S.; Thomassen, P.; Walker, M.; Delannoy, A. G.; Foerster, M.; Heideman, J.; Riley, G.; Rose, K.; Spanier, S.; Thapa, K.; Bouhali, O.; Castaneda Hernandez, A.; Celik, A.; Dalchenko, M.; De Mattia, M.; Delgado, A.; Dildick, S.; Eusebi, R.; Gilmore, J.; Huang, T.; Kamon, T.; Mueller, R.; Pakhotin, Y.; Patel, R.; Perloff, A.; Perniè, L.; Rathjens, D.; Safonov, A.; Tatarinov, A.; Ulmer, K. A.; Akchurin, N.; Damgov, J.; De Guio, F.; Dudero, P. R.; Faulkner, J.; Gurpinar, E.; Kunori, S.; Lamichhane, K.; Lee, S. W.; Libeiro, T.; Peltola, T.; Undleeb, S.; Volobouev, I.; Wang, Z.; Greene, S.; Gurrola, A.; Janjam, R.; Johns, W.; Maguire, C.; Melo, A.; Ni, H.; Padeken, K.; Sheldon, P.; Tuo, S.; Velkovska, J.; Xu, Q.; Arenton, M. W.; Barria, P.; Cox, B.; Hirosky, R.; Joyce, M.; Ledovskoy, A.; Li, H.; Neu, C.; Sinthuprasith, T.; Wang, Y.; Wolfe, E.; Xia, F.; Harr, R.; Karchin, P. E.; Sturdy, J.; Zaleski, S.; Brodski, M.; Buchanan, J.; Caillol, C.; Dasu, S.; Dodd, L.; Duric, S.; Gomber, B.; Grothe, M.; Herndon, M.; Hervé, A.; Hussain, U.; Klabbers, P.; Lanaro, A.; Levine, A.; Long, K.; Loveless, R.; Pierro, G. A.; Polese, G.; Ruggles, T.; Savin, A.; Smith, N.; Smith, W. H.; Taylor, D.; Woods, N.; CMS Collaboration
2018-04-01
A measurement of the H → ττ signal strength is performed using events recorded in proton-proton collisions by the CMS experiment at the LHC in 2016 at a center-of-mass energy of 13TeV. The data set corresponds to an integrated luminosity of 35.9fb-1. The H → ττ signal is established with a significance of 4.9 standard deviations, to be compared to an expected significance of 4.7 standard deviations. The best fit of the product of the observed H → ττ signal production cross section and branching fraction is 1.09-0.26+0.27 times the standard model expectation. The combination with the corresponding measurement performed with data collected by the CMS experiment at center-of-mass energies of 7 and 8TeV leads to an observed significance of 5.9 standard deviations, equal to the expected significance. This is the first observation of Higgs boson decays to τ leptons by a single experiment.
NASA Astrophysics Data System (ADS)
Alamirew, Netsanet K.; Todd, Martin C.; Ryder, Claire L.; Marsham, John H.; Wang, Yi
2018-01-01
The Saharan heat low (SHL) is a key component of the west African climate system and an important driver of the west African monsoon across a range of timescales of variability. The physical mechanisms driving the variability in the SHL remain uncertain, although water vapour has been implicated as of primary importance. Here, we quantify the independent effects of variability in dust and water vapour on the radiation budget and atmospheric heating of the region using a radiative transfer model configured with observational input data from the Fennec field campaign at the location of Bordj Badji Mokhtar (BBM) in southern Algeria (21.4° N, 0.9° E), close to the SHL core for June 2011. Overall, we find dust aerosol and water vapour to be of similar importance in driving variability in the top-of-atmosphere (TOA) radiation budget and therefore the column-integrated heating over the SHL (˜ 7 W m-2 per standard deviation of dust aerosol optical depth - AOD). As such, we infer that SHL intensity is likely to be similarly enhanced by the effects of dust and water vapour surge events. However, the details of the processes differ. Dust generates substantial radiative cooling at the surface (˜ 11 W m-2 per standard deviation of dust AOD), presumably leading to reduced sensible heat flux in the boundary layer, which is more than compensated by direct radiative heating from shortwave (SW) absorption by dust in the dusty boundary layer. In contrast, water vapour invokes a radiative warming at the surface of ˜ 6 W m-2 per standard deviation of column-integrated water vapour in kg m-2. Net effects involve a pronounced net atmospheric radiative convergence with heating rates on average of 0.5 K day-1 and up to 6 K day-1 during synoptic/mesoscale dust events from monsoon surges and convective cold-pool outflows (haboobs
). On this basis, we make inferences on the processes driving variability in the SHL associated with radiative and advective heating/cooling. Depending on the synoptic context over the region, processes driving variability involve both independent effects of water vapour and dust and compensating events in which dust and water vapour are co-varying. Forecast models typically have biases of up to 2 kg m-2 in column-integrated water vapour (equivalent to a change in 2.6 W m-2 TOA net flux) and typically lack variability in dust and thus are expected to poorly represent these couplings. An improved representation of dust and water vapour and quantification of associated radiative impact in models is thus imperative to further understand the SHL and related climate processes.
Passive PE Sampling in Support of In Situ Remediation of Contaminated Sediments
2015-08-01
control RPD relative percent difference RSD relative standard deviation SERDP Strategic Environmental Research and Development Program SOPs...sediments from 2 stations, each at 4 PCB spike levels, for four individual congeners was 22 ± 6 % relative standard deviation ( RSD ). Also, comparison of... RSD (Table 3). However, larger congeners (e.g., congeners #153 and 180) whose approach to equilibrium is less certain, based on small fractions of
NASA Astrophysics Data System (ADS)
Mohammadian, Shahabeddin K.; Zhang, Yuwen
2015-01-01
Three dimensional transient thermal analysis of an air-cooled module that contains prismatic Li-ion cells next to a special kind of aluminum pin fin heat sink whose heights of pin fins increase linearly through the width of the channel in air flow direction was studied for thermal management of Lithium-ion battery pack. The effects of pin fins arrangements, discharge rates, inlet air flow velocities, and inlet air temperatures on the battery were investigated. The results showed that despite of heat sinks with uniform pin fin heights that increase the standard deviation of the temperature field, using this kind of pin fin heat sink compare to the heat sink without pin fins not only decreases the bulk temperature inside the battery, but also decreases the standard deviation of the temperature field inside the battery as well. Increasing the inlet air temperature leads to decreasing the standard deviation of the temperature field while increases the maximum temperature of the battery. Furthermore, increasing the inlet air velocity first increases the standard deviation of the temperature field till reaches to the maximum point, and after that decreases. Also, increasing the inlet air velocity leads to decrease in the maximum temperature of the battery.
Teixeira da Silva, Jaime A; Dobránszki, Judit
2017-04-01
A retraction notice is an essential scientific historical document because it should outline the reason(s) why a scientific manuscript was retracted, culpability (if any) and any other factors that have given reason for the authors, editors, or publisher, to remove a piece of the literature from science's history books. Unlike an expression of concern (EoC), erratum or corrigendum, a retraction will usually result in a rudimentary vestige of the work. Thus, any retraction notice that does not fully indicate a set of elements related to the reason and background for the retraction serves as a poor historical document. Moreover, poorly or incompletely worded retraction notices in fact do not serve their intended purpose, i.e., to hold all parties accountable, and to inform the scientific and wider public of the problem and reason for the paper's demise. This paper takes a look at the definitions and the policies of clauses for retractions, EoCs, errata and corrigenda in place by 15 leading science, technology and medicine (STM) publishers and four publishing-related bodies that we believe have the greatest influence on the current fields of science, technology and medicine. The primary purpose was to assess whether there is a consistency among these entities and publishers. Using an arbitrary 5-scale classification system, and evaluating the different categories of policies separately, we discovered that in almost all cases (88.9 %), the wording used to define these four categories of polices differs from that of the Committee on Publication Ethics (COPE), which is generally considered to be the guiding set of definitions in science publishing. In addition, as much as 61 % deviation in policies (wording and meaning), relative to COPE guidelines, was discovered. When considering the average pooled deviation across all categories of policies, we discovered that there was either no deviation or a small deviation, only in the wording, in the definition of policies when compared to the COPE guidelines in 1 out of 3 ethical bodies, and in 40 % (6 out of 15) STM publishers. Moderate deviation from the COPE guidelines was detected in 26.7 % of STM publishers and one ethical body but a large deviation in one ethical body and 20 % of STM publishers was observed. Two STM publishers (13.3 %) did not report any information about these policies. Even though in practice, editors and publishers may deviate from these written definitions when dealing with case-by-case issues, we believe that it is essential, to serve as a consistent guide for authors and editors, that the wording be standardized across these entities. COPE and these entities also have the responsibility of making it clear that these definitions are merely suggestions and that their application may be subjected to subjective interpretation and application.
The linear sizes tolerances and fits system modernization
NASA Astrophysics Data System (ADS)
Glukhov, V. I.; Grinevich, V. A.; Shalay, V. V.
2018-04-01
The study is carried out on the urgent topic for technical products quality providing in the tolerancing process of the component parts. The aim of the paper is to develop alternatives for improving the system linear sizes tolerances and dimensional fits in the international standard ISO 286-1. The tasks of the work are, firstly, to classify as linear sizes the elements additionally linear coordinating sizes that determine the detail elements location and, secondly, to justify the basic deviation of the tolerance interval for the element's linear size. The geometrical modeling method of real details elements, the analytical and experimental methods are used in the research. It is shown that the linear coordinates are the dimensional basis of the elements linear sizes. To standardize the accuracy of linear coordinating sizes in all accuracy classes, it is sufficient to select in the standardized tolerance system only one tolerance interval with symmetrical deviations: Js for internal dimensional elements (holes) and js for external elements (shafts). The main deviation of this coordinating tolerance is the average zero deviation, which coincides with the nominal value of the coordinating size. Other intervals of the tolerance system are remained for normalizing the accuracy of the elements linear sizes with a fundamental change in the basic deviation of all tolerance intervals is the maximum deviation corresponding to the limit of the element material: EI is the lower tolerance for the of the internal elements (holes) sizes and es is the upper tolerance deviation for the outer elements (shafts) sizes. It is the sizes of the material maximum that are involved in the of the dimensional elements mating of the shafts and holes and determine the fits type.
Code of Federal Regulations, 2014 CFR
2014-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
Code of Federal Regulations, 2011 CFR
2011-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
Code of Federal Regulations, 2012 CFR
2012-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
Code of Federal Regulations, 2013 CFR
2013-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
Ishibashi, Hiroki; Takano, Masashi; Sasa, Hidenori; Furuya, Kenichi
2016-01-01
Background Placenta previa, one of the most severe obstetric complications, carries an increased risk of intraoperative massive hemorrhage. Several risk factors for intraoperative hemorrhage have been identified to date. However, the correlation between birth weight and intraoperative hemorrhage has not been investigated. Here we estimate the correlation between birth weight and the occurrence of intraoperative massive hemorrhage in placenta previa. Materials and Methods We included all 256 singleton pregnancies delivered via cesarean section at our hospital because of placenta previa between 2003 and 2015. We calculated not only measured birth weights but also standard deviation values according to the Japanese standard growth curve to adjust for differences in gestational age. We assessed the correlation between birth weight and the occurrence of intraoperative massive hemorrhage (>1500 mL blood loss). Receiver operating characteristic curves were constructed to determine the cutoff value of intraoperative massive hemorrhage. Results Of 256 pregnant women with placenta previa, 96 (38%) developed intraoperative massive hemorrhage. Receiver-operating characteristic curves revealed that the area under the curve of the combination variables between the standard deviation of birth weight and intraoperative massive hemorrhage was 0.71. The cutoff value with a sensitivity of 81.3% and specificity of 55.6% was −0.33 standard deviation. The multivariate analysis revealed that a standard deviation of >−0.33 (odds ratio, 5.88; 95% confidence interval, 3.04–12.00), need for hemostatic procedures (odds ratio, 3.31; 95% confidence interval, 1.79–6.25), and placental adhesion (odds ratio, 12.68; 95% confidence interval, 2.85–92.13) were independent risk of intraoperative massive hemorrhage. Conclusion In patients with placenta previa, a birth weight >−0.33 standard deviation was a significant risk indicator of massive hemorrhage during cesarean section. Based on this result, further studies are required to investigate whether fetal weight estimated by ultrasonography can predict hemorrhage during cesarean section in patients with placental previa. PMID:27902772
Soyama, Hiroaki; Miyamoto, Morikazu; Ishibashi, Hiroki; Takano, Masashi; Sasa, Hidenori; Furuya, Kenichi
2016-01-01
Placenta previa, one of the most severe obstetric complications, carries an increased risk of intraoperative massive hemorrhage. Several risk factors for intraoperative hemorrhage have been identified to date. However, the correlation between birth weight and intraoperative hemorrhage has not been investigated. Here we estimate the correlation between birth weight and the occurrence of intraoperative massive hemorrhage in placenta previa. We included all 256 singleton pregnancies delivered via cesarean section at our hospital because of placenta previa between 2003 and 2015. We calculated not only measured birth weights but also standard deviation values according to the Japanese standard growth curve to adjust for differences in gestational age. We assessed the correlation between birth weight and the occurrence of intraoperative massive hemorrhage (>1500 mL blood loss). Receiver operating characteristic curves were constructed to determine the cutoff value of intraoperative massive hemorrhage. Of 256 pregnant women with placenta previa, 96 (38%) developed intraoperative massive hemorrhage. Receiver-operating characteristic curves revealed that the area under the curve of the combination variables between the standard deviation of birth weight and intraoperative massive hemorrhage was 0.71. The cutoff value with a sensitivity of 81.3% and specificity of 55.6% was -0.33 standard deviation. The multivariate analysis revealed that a standard deviation of >-0.33 (odds ratio, 5.88; 95% confidence interval, 3.04-12.00), need for hemostatic procedures (odds ratio, 3.31; 95% confidence interval, 1.79-6.25), and placental adhesion (odds ratio, 12.68; 95% confidence interval, 2.85-92.13) were independent risk of intraoperative massive hemorrhage. In patients with placenta previa, a birth weight >-0.33 standard deviation was a significant risk indicator of massive hemorrhage during cesarean section. Based on this result, further studies are required to investigate whether fetal weight estimated by ultrasonography can predict hemorrhage during cesarean section in patients with placental previa.
El Beltagi, Tarek A; Bowd, Christopher; Boden, Catherine; Amini, Payam; Sample, Pamela A; Zangwill, Linda M; Weinreb, Robert N
2003-11-01
To determine the relationship between areas of glaucomatous retinal nerve fiber layer thinning identified by optical coherence tomography and areas of decreased visual field sensitivity identified by standard automated perimetry in glaucomatous eyes. Retrospective observational case series. Forty-three patients with glaucomatous optic neuropathy identified by optic disc stereo photographs and standard automated perimetry mean deviations >-8 dB were included. Participants were imaged with optical coherence tomography within 6 months of reliable standard automated perimetry testing. The location and number of optical coherence tomography clock hour retinal nerve fiber layer thickness measures outside normal limits were compared with the location and number of standard automated perimetry visual field zones outside normal limits. Further, the relationship between the deviation from normal optical coherence tomography-measured retinal nerve fiber layer thickness at each clock hour and the average pattern deviation in each visual field zone was examined by using linear regression (R(2)). The retinal nerve fiber layer areas most frequently outside normal limits were the inferior and inferior temporal regions. The least sensitive visual field zones were in the superior hemifield. Linear regression results (R(2)) showed that deviation from the normal retinal nerve fiber layer thickness at optical coherence tomography clock hour positions 6 o'clock, 7 o'clock, and 8 o'clock (inferior and inferior temporal) was best correlated with standard automated perimetry pattern deviation in visual field zones corresponding to the superior arcuate and nasal step regions (R(2) range, 0.34-0.57). These associations were much stronger than those between clock hour position 6 o'clock and the visual field zone corresponding to the inferior nasal step region (R(2) = 0.01). Localized retinal nerve fiber layer thinning, measured by optical coherence tomography, is topographically related to decreased localized standard automated perimetry sensitivity in glaucoma patients.
Pooling biomarker data from different studies of disease risk, with a focus on endogenous hormones
Key, Timothy J; Appleby, Paul N; Allen, Naomi E; Reeves, Gillian K
2010-01-01
Large numbers of observations are needed to provide adequate power in epidemiological studies of biomarkers and cancer risk. However, there are currently few large mature studies with adequate numbers of cases with biospecimens available. Therefore pooling biomarker measures from different studies is a valuable approach, enabling investigators to make robust estimates of risk and to examine associations in subgroups of the population. The ideal situation is to have standardized methods in all studies so that the biomarker data can be pooled in their original units. However, even when the studies do not have standardized methods, as with existing studies on hormones and cancer, a simple approach using study-specific quantiles or percentage increases can provide substantial information on the relationship of the biomarker with cancer risk. PMID:20233851
Automating linear accelerator quality assurance.
Eckhause, Tobias; Al-Hallaq, Hania; Ritter, Timothy; DeMarco, John; Farrey, Karl; Pawlicki, Todd; Kim, Gwe-Ya; Popple, Richard; Sharma, Vijeshwar; Perez, Mario; Park, SungYong; Booth, Jeremy T; Thorwarth, Ryan; Moran, Jean M
2015-10-01
The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.
Fission matrix-based Monte Carlo criticality analysis of fuel storage pools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farlotti, M.; Ecole Polytechnique, Palaiseau, F 91128; Larsen, E. W.
2013-07-01
Standard Monte Carlo transport procedures experience difficulties in solving criticality problems in fuel storage pools. Because of the strong neutron absorption between fuel assemblies, source convergence can be very slow, leading to incorrect estimates of the eigenvalue and the eigenfunction. This study examines an alternative fission matrix-based Monte Carlo transport method that takes advantage of the geometry of a storage pool to overcome this difficulty. The method uses Monte Carlo transport to build (essentially) a fission matrix, which is then used to calculate the criticality and the critical flux. This method was tested using a test code on a simplemore » problem containing 8 assemblies in a square pool. The standard Monte Carlo method gave the expected eigenfunction in 5 cases out of 10, while the fission matrix method gave the expected eigenfunction in all 10 cases. In addition, the fission matrix method provides an estimate of the error in the eigenvalue and the eigenfunction, and it allows the user to control this error by running an adequate number of cycles. Because of these advantages, the fission matrix method yields a higher confidence in the results than standard Monte Carlo. We also discuss potential improvements of the method, including the potential for variance reduction techniques. (authors)« less
Effective classification of the prevalence of Schistosoma mansoni.
Mitchell, Shira A; Pagano, Marcello
2012-12-01
To present an effective classification method based on the prevalence of Schistosoma mansoni in the community. We created decision rules (defined by cut-offs for number of positive slides), which account for imperfect sensitivity, both with a simple adjustment of fixed sensitivity and with a more complex adjustment of changing sensitivity with prevalence. To reduce screening costs while maintaining accuracy, we propose a pooled classification method. To estimate sensitivity, we use the De Vlas model for worm and egg distributions. We compare the proposed method with the standard method to investigate differences in efficiency, measured by number of slides read, and accuracy, measured by probability of correct classification. Modelling varying sensitivity lowers the lower cut-off more significantly than the upper cut-off, correctly classifying regions as moderate rather than lower, thus receiving life-saving treatment. The classification method goes directly to classification on the basis of positive pools, avoiding having to know sensitivity to estimate prevalence. For model parameter values describing worm and egg distributions among children, the pooled method with 25 slides achieves an expected 89.9% probability of correct classification, whereas the standard method with 50 slides achieves 88.7%. Among children, it is more efficient and more accurate to use the pooled method for classification of S. mansoni prevalence than the current standard method. © 2012 Blackwell Publishing Ltd.
Roy, Krisna; Kjelgaard-Hansen, Mads; Pors, Susanne Elisabeth; Christensen, Jens Peter; Biswas, Paritosh Kumar; Bojesen, Anders Miki
2014-01-01
To evaluate Ovo-transferrin (OTF), a positive acute-phase protein in chickens, as a diagnostic biomarker of selected bacterial infections we checked the performance of a commercial Chicken-OTF-ELISA (ICL, Inc., Portland, OR, USA) by analytical and overlap performances using two groups of serum samples obtained from 26 Gallibacterium anatis-infected and 20 Streptococcus zooepidemicus-infected brown layer chickens. In addition, sera from 14 apparently healthy and 19 negative control chickens were analysed in the Gallibacterium group whereas sera from 20 healthy and 11 negative control chickens from the Streptococcus group were analysed. All calibration curves revealed high coefficients of determination (≥ 0.97) between optical density (OD 450nm) and concentrations of OTF (mg/ml). OTF concentrations in high, medium and low pools (made of sera from a combination of infected and/or non-infected birds) were >6.4, >3.8 to <4.5 and <1.6 mg/ml in the Gallibacterium group, and >6.7, >3.5 to <3.7 and <1.1 mg/ml in the Streptococcus group, respectively. For each pool, low coefficients of intra-assay (7.8, 5.7 and 5.3) and inter-assay (15.8, 18.0 and 18.0) variations were obtained in the Gallibacterium study. In the Streptococcus study only the intra-assay variation was low (3.7, 3.8 and 6.2, respectively). The linearity check was acceptable demonstrating a straight line with slope and intercept, not deviating from one and zero, respectively, using the Gallibacterium sera, whereas the Streptococcus sera deviated from the linear line. Detection limits were low (Gallibacterium, 0.01 mg/ml; Streptococcus, 0.32 mg/ml). OTF concentrations (mean ± standard error of the mean) in overlap performances were elevated in the sera of infected chickens (Gallibacterium, 4.4 ± 0.3 mg/ml; Streptococcus, 3.2 ± 0.4 mg/ml) compared with negative controls (1.7 ± 0.1 mg/ml) (P < 0.05). In conclusion, the Chicken-OTF-ELISA can be used to measure reproducible serum OTF concentrations in brown layer chickens as a response to G. anatis infections, whereas an adjustment of dilution process is proposed to optimize to use in S. zooepidemicus-infected chickens.
Morandi, Pierre-Alain; Schockmel, Gérard A.; Yerly, Sabine; Burgisser, Philippe; Erb, Peter; Matter, Lukas; Sitavanc, Radan; Perrin, Luc
1998-01-01
A total of 234 pools were prepared from 10,692 consecutive serum samples negative for antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 collected at five virological laboratories (average pool size, 45 serum samples). Pools were screened for the presence of HIV-1 RNA by a modified commercial assay (Amplicor HIV-1 Monitor test) which included an additional polyethylene glycol (PEG) precipitation step prior to purification of viral RNA (PEG Amplicor assay). The sensitivity of this assay for HIV-1 RNA detection in individual serum samples within pools matches that of standard commercial assays for individual serum samples, i.e., 500 HIV-1 RNA copies per ml. Five pools were identified as positive, and each one contained one antibody-negative, HIV-1 RNA-positive serum sample, corresponding to an average of 1 infected sample per 2,138 serum samples. Retrospective analysis revealed that the five HIV-1 RNA-positive specimens originated from individuals who had symptomatic primary HIV-1 infection at the time of sample collection and who were also positive for p24 antigenemia. We next assessed the possibility of performing the prepurification step by high-speed centrifugation (50,000 × g for 80 min) of 1.5-ml pools containing 25 μl of 60 individual serum samples, of which only 1 contained HIV-1 RNA (centrifugation Amplicor assay). The sensitivity of this assay also matches the sensitivities of standard commercial assays for HIV-1 RNA detection in individual serum samples. The results demonstrate that both assays with pooled sera can be applied to the screening of large numbers of serum samples in a time- and cost-efficient manner. PMID:9620372
45 CFR 153.250 - Coordination with high-risk pools.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 45 Public Welfare 1 2012-10-01 2012-10-01 false Coordination with high-risk pools. 153.250 Section 153.250 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES REQUIREMENTS RELATING TO HEALTH CARE ACCESS STANDARDS RELATED TO REINSURANCE, RISK CORRIDORS, AND RISK ADJUSTMENT UNDER THE AFFORDABLE CARE...
45 CFR 153.250 - Coordination with high-risk pools.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 45 Public Welfare 1 2014-10-01 2014-10-01 false Coordination with high-risk pools. 153.250 Section 153.250 Public Welfare Department of Health and Human Services REQUIREMENTS RELATING TO HEALTH CARE ACCESS STANDARDS RELATED TO REINSURANCE, RISK CORRIDORS, AND RISK ADJUSTMENT UNDER THE AFFORDABLE CARE...
45 CFR 153.250 - Coordination with high-risk pools.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 45 Public Welfare 1 2013-10-01 2013-10-01 false Coordination with high-risk pools. 153.250 Section 153.250 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES REQUIREMENTS RELATING TO HEALTH CARE ACCESS STANDARDS RELATED TO REINSURANCE, RISK CORRIDORS, AND RISK ADJUSTMENT UNDER THE AFFORDABLE CARE...
21 CFR 640.69 - General requirements.
Code of Federal Regulations, 2012 CFR
2012-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.69 General requirements. (a) Pooling. Two units of Source Plasma from the same donor may be pooled if such units are collected during... introduce a risk of contamination of the red blood cells and, for plasma intended for injectable products...
21 CFR 640.69 - General requirements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.69 General requirements. (a) Pooling. Two units of Source Plasma from the same donor may be pooled if such units are collected during... introduce a risk of contamination of the red blood cells and, for plasma intended for injectable products...
21 CFR 640.69 - General requirements.
Code of Federal Regulations, 2013 CFR
2013-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.69 General requirements. (a) Pooling. Two units of Source Plasma from the same donor may be pooled if such units are collected during... introduce a risk of contamination of the red blood cells and, for plasma intended for injectable products...
21 CFR 640.69 - General requirements.
Code of Federal Regulations, 2014 CFR
2014-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.69 General requirements. (a) Pooling. Two units of Source Plasma from the same donor may be pooled if such units are collected during... introduce a risk of contamination of the red blood cells and, for plasma intended for injectable products...
In vivo dosimetry for external photon treatments of head and neck cancers by diodes and TLDS.
Tung, C J; Wang, H C; Lo, S H; Wu, J M; Wang, C J
2004-01-01
In vivo dosimetry was implemented for treatments of head and neck cancers in the large fields. Diode and thermoluminescence dosemeter (TLD) measurements were carried out for the linear accelerators of 6 MV photon beams. ESTRO in vivo dosimetry protocols were followed in the determination of midline doses from measurements of entrance and exit doses. Of the fields monitored by diodes, the maximum absolute deviation of measured midline doses from planned target doses was 8%, with the mean value and the standard deviation of -1.0 and 2.7%. If planned target doses were calculated using radiological water equivalent thicknesses rather than patient geometric thicknesses, the maximum absolute deviation dropped to 4%, with the mean and the standard deviation of 0.7 and 1.8%. For in vivo dosimetry monitored by TLDs, the shift in mean dose remained small but the statistical precision became poor.
A visual tristimulus projection colorimeter.
Valberg, A
1971-01-01
Based on the optical principle of a slide projector, a visual tristimulus projection colorimeter has been developed. The calorimeter operates with easily interchangeable sets of primary color filters placed in a frame at the objective. The apparatus has proved to be fairly accurate. The reproduction of the color matches as measured by the standard deviation is equal to the visual sensitivity to color differences for each observer. Examples of deviations in the matches among individuals as well as deviations compared with the CIE 1931 Standard Observer are given. These deviations are demonstrated to be solely due to individual differences in the perception of metameric colors. Thus, taking advantage of an objective observation (allowing all adjustments to be judged by a group of impartial observers), the colorimeter provides an excellent aid in the study of discrimination, metamerism, and related effects which are of considerable interest in current research in colorimetry and in the study of color vision tests.
Discriminating crop and other canopies by overlapping binary image layers
NASA Astrophysics Data System (ADS)
Doi, Ryoichi
2013-02-01
For optimal management of agricultural fields by remote sensing, discrimination of the crop canopy from weeds and other objects is essential. In a digital photograph, a rice canopy was discriminated from a variety of weed and tree canopies and other objects by overlapping binary image layers of red-green-blue and other color components indicating the pixels with target canopy-specific (intensity) values based on the ranges of means ±(3×) standard deviations. By overlapping and merging the binary image layers, the target canopy specificity improved to 0.0015 from 0.027 for the yellow 1× standard deviation binary image layer, which was the best among all combinations of color components and means ±(3×) standard deviations. The most target rice canopy-likely pixels were further identified by limiting the pixels at different luminosity values. The discriminatory power was also visually demonstrated in this manner.
Middle school transition and body weight outcomes: Evidence from Arkansas Public Schoolchildren.
Zeng, Di; Thomsen, Michael R; Nayga, Rodolfo M; Rouse, Heather L
2016-05-01
There is evidence that middle school transition adversely affects educational and psychological outcomes of pre-teen children, but little is known about the impacts of middle school transition on other aspects of health. In this article, we estimate the impact of middle school transition on the body mass index (BMI) of public schoolchildren in Arkansas, United States. Using an instrumental variable approach, we find that middle school transition in grade 6 led to a moderate decrease of 0.04 standard deviations in BMI z-scores for all students. Analysis by subsample indicated that this result was driven by boys (0.06-0.07 standard deviations) and especially by non-minority boys (0.09 standard deviations). We speculate that the changing levels of physical activities associated with middle school transition provide the most reasonable explanation for this result. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jafarov, E. E.; Parsekian, A. D.; Schaefer, K.
Ground penetrating radar (GPR) has emerged as an effective tool for estimating active layer thickness (ALT) and volumetric water content (VWC) within the active layer. In August 2013, we conducted a series of GPR and probing surveys using a 500 MHz antenna and metallic probe around Barrow, Alaska. Here, we collected about 15 km of GPR data and 1.5 km of probing data. We describe the GPR data processing workflow from raw GPR data to the estimated ALT and VWC. We then include the corresponding uncertainties for each measured and estimated parameter. The estimated average GPR-derived ALT was 41 cm,more » with a standard deviation of 9 cm. The average probed ALT was 40 cm, with a standard deviation of 12 cm. The average GPR-derived VWC was 0.65, with a standard deviation of 0.14.« less
Migration in the shearing sheet and estimates for young open cluster migration
NASA Astrophysics Data System (ADS)
Quillen, Alice C.; Nolting, Eric; Minchev, Ivan; De Silva, Gayandhi; Chiappini, Cristina
2018-04-01
Using tracer particles embedded in self-gravitating shearing sheet N-body simulations, we investigate the distance in guiding centre radius that stars or star clusters can migrate in a few orbital periods. The standard deviations of guiding centre distributions and maximum migration distances depend on the Toomre or critical wavelength and the contrast in mass surface density caused by spiral structure. Comparison between our simulations and estimated guiding radii for a few young supersolar metallicity open clusters, including NGC 6583, suggests that the contrast in mass surface density in the solar neighbourhood has standard deviation (in the surface density distribution) divided by mean of about 1/4 and larger than measured using COBE data by Drimmel and Spergel. Our estimate is consistent with a standard deviation of ˜0.07 dex in the metallicities measured from high-quality spectroscopic data for 38 young open clusters (<1 Gyr) with mean galactocentric radius 7-9 kpc.
Jafarov, E. E.; Parsekian, A. D.; Schaefer, K.; ...
2018-01-09
Ground penetrating radar (GPR) has emerged as an effective tool for estimating active layer thickness (ALT) and volumetric water content (VWC) within the active layer. In August 2013, we conducted a series of GPR and probing surveys using a 500 MHz antenna and metallic probe around Barrow, Alaska. Here, we collected about 15 km of GPR data and 1.5 km of probing data. We describe the GPR data processing workflow from raw GPR data to the estimated ALT and VWC. We then include the corresponding uncertainties for each measured and estimated parameter. The estimated average GPR-derived ALT was 41 cm,more » with a standard deviation of 9 cm. The average probed ALT was 40 cm, with a standard deviation of 12 cm. The average GPR-derived VWC was 0.65, with a standard deviation of 0.14.« less
The Cost of Uncertain Life Span*
Edwards, Ryan D.
2012-01-01
A considerable amount of uncertainty surrounds the length of human life. The standard deviation in adult life span is about 15 years in the U.S., and theory and evidence suggest it is costly. I calibrate a utility-theoretic model of preferences over length of life and show that one fewer year in standard deviation is worth about half a mean life year. Differences in the standard deviation exacerbate cross-sectional differences in life expectancy between the U.S. and other industrialized countries, between rich and poor countries, and among poor countries. Accounting for the cost of life-span variance also appears to amplify recently discovered patterns of convergence in world average human well-being. This is partly for methodological reasons and partly because unconditional variance in human length of life, primarily the component due to infant mortality, has exhibited even more convergence than life expectancy. PMID:22368324
On the linear relation between the mean and the standard deviation of a response time distribution.
Wagenmakers, Eric-Jan; Brown, Scott
2007-07-01
Although it is generally accepted that the spread of a response time (RT) distribution increases with the mean, the precise nature of this relation remains relatively unexplored. The authors show that in several descriptive RT distributions, the standard deviation increases linearly with the mean. Results from a wide range of tasks from different experimental paradigms support a linear relation between RT mean and RT standard deviation. Both R. Ratcliff's (1978) diffusion model and G. D. Logan's (1988) instance theory of automatization provide explanations for this linear relation. The authors identify and discuss 3 specific boundary conditions for the linear law to hold. The law constrains RT models and supports the use of the coefficient of variation to (a) compare variability while controlling for differences in baseline speed of processing and (b) assess whether changes in performance with practice are due to quantitative speedup or qualitative reorganization. Copyright 2007 APA.
Determination of the optimal level for combining area and yield estimates
NASA Technical Reports Server (NTRS)
Bauer, M. E. (Principal Investigator); Hixson, M. M.; Jobusch, C. D.
1981-01-01
Several levels of obtaining both area and yield estimates of corn and soybeans in Iowa were considered: county, refined strata, refined/split strata, crop reporting district, and state. Using the CCEA model form and smoothed weather data, regression coefficients at each level were derived to compute yield and its variance. Variances were also computed with stratum level. The variance of the yield estimates was largest at the state and smallest at the county level for both crops. The refined strata had somewhat larger variances than those associated with the refined/split strata and CRD. For production estimates, the difference in standard deviations among levels was not large for corn, but for soybeans the standard deviation at the state level was more than 50% greater than for the other levels. The refined strata had the smallest standard deviations. The county level was not considered in evaluation of production estimates due to lack of county area variances.
Quantifying relative importance: Computing standardized effects in models with binary outcomes
Grace, James B.; Johnson, Darren; Lefcheck, Jonathan S.; Byrnes, Jarrett E.K.
2018-01-01
Results from simulation studies show that both the LT and OE methods of standardization support a similarly-broad range of coefficient comparisons. The LT method estimates effects that reflect underlying latent-linear propensities, while the OE method computes a linear approximation for the effects of predictors on binary responses. The contrast between assumptions for the two methods is reflected in persistently weaker standardized effects associated with OE standardization. Reliance on standard deviations for standardization (the traditional approach) is critically examined and shown to introduce substantial biases when predictors are non-Gaussian. The use of relevant ranges in place of standard deviations has the capacity to place LT and OE standardized coefficients on a more comparable scale. As ecologists address increasingly complex hypotheses, especially those that involve comparing the influences of different controlling factors (e.g., top-down versus bottom-up or biotic versus abiotic controls), comparable coefficients become a necessary component for evaluations.
48 CFR 9904.420-60 - Illustrations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... STANDARDS COST ACCOUNTING STANDARDS 9904.420-60 Illustrations. (a) Business Unit A's engineering department... typing its overhead cost pool. In submitting a proposal, the engineering department assigns several... Section 9904.420-60 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD, OFFICE OF...
Lima, Thiago G; Willett, Christopher S
2018-05-11
The formation of reproductive barriers between allopatric populations involves the accumulation of incompatibilities that lead to intrinsic postzygotic isolation. The evolution of these incompatibilities is usually explained by the Dobzhansky-Muller model, where epistatic interactions that arise within the diverging populations, lead to deleterious interactions when they come together in a hybrid genome. These incompatibilities can lead to hybrid inviability, killing individuals with certain genotypic combinations, and causing the population's allele frequency to deviate from Mendelian expectations. Traditionally, hybrid inviability loci have been detected by genotyping individuals at different loci across the genome. However, this method becomes time consuming and expensive as the number of markers or individuals increases. Here, we test if a Pool-seq method can be used to scan the genome of F2 hybrids to detect genomic regions that are affected by hybrid inviability. We survey the genome of hybrids between 2 populations of the copepod Tigriopus californicus, and show that this method has enough power to detect even small changes in allele frequency caused by hybrid inviability. We show that allele frequency estimates in Pool-seq can be affected by the sampling of alleles from the pool of DNA during the library preparation and sequencing steps and that special considerations must be taken when aligning hybrid reads to a reference when the populations/species are divergent.
Comparison of variance estimators for meta-analysis of instrumental variable estimates
Schmidt, AF; Hingorani, AD; Jefferis, BJ; White, J; Groenwold, RHH; Dudbridge, F
2016-01-01
Abstract Background: Mendelian randomization studies perform instrumental variable (IV) analysis using genetic IVs. Results of individual Mendelian randomization studies can be pooled through meta-analysis. We explored how different variance estimators influence the meta-analysed IV estimate. Methods: Two versions of the delta method (IV before or after pooling), four bootstrap estimators, a jack-knife estimator and a heteroscedasticity-consistent (HC) variance estimator were compared using simulation. Two types of meta-analyses were compared, a two-stage meta-analysis pooling results, and a one-stage meta-analysis pooling datasets. Results: Using a two-stage meta-analysis, coverage of the point estimate using bootstrapped estimators deviated from nominal levels at weak instrument settings and/or outcome probabilities ≤ 0.10. The jack-knife estimator was the least biased resampling method, the HC estimator often failed at outcome probabilities ≤ 0.50 and overall the delta method estimators were the least biased. In the presence of between-study heterogeneity, the delta method before meta-analysis performed best. Using a one-stage meta-analysis all methods performed equally well and better than two-stage meta-analysis of greater or equal size. Conclusions: In the presence of between-study heterogeneity, two-stage meta-analyses should preferentially use the delta method before meta-analysis. Weak instrument bias can be reduced by performing a one-stage meta-analysis. PMID:27591262
Alternative volume performance standards for Medicare physicians' services.
Marquis, M S; Kominski, G F
1994-01-01
The Omnibus Budget Reconciliation Act of 1989 (OBRA89) established volume performance standards (VPSs) as a key element in Medicare physician reform. This policy requires making choices along three dimensions: the risk pool, the scope and nature of the standard, and the application of the standard. VPSs have most effectively controlled expenditures and changed physician behavior when they use states as the risk pool, are composed entirely of Medicare Part B services, and establish per capita utilization targets. The institution of separate standards for voluntarily formed physician groups would pose substantial administrative challenges and has the potential to effect adverse outcomes. Instead, Congress should continue to encourage prepaid plans for the purpose of lowering health care use. Under current law, VPSs will be used to adjust future price increases. Congress may not wish to emulate the example of countries that have imposed expenditure ceilings to control costs unless the current method of using VPSs proves unsuccessful.
Admixture Aberration Analysis: Application to Mapping in Admixed Population Using Pooled DNA
NASA Astrophysics Data System (ADS)
Bercovici, Sivan; Geiger, Dan
Admixture mapping is a gene mapping approach used for the identification of genomic regions harboring disease susceptibility genes in the case of recently admixed populations such as African Americans. We present a novel method for admixture mapping, called admixture aberration analysis (AAA), that uses a DNA pool of affected admixed individuals. We demonstrate through simulations that AAA is a powerful and economical mapping method under a range of scenarios, capturing complex human diseases such as hypertension and end stage kidney disease. The method has a low false-positive rate and is robust to deviation from model assumptions. Finally, we apply AAA on 600 prostate cancer-affected African Americans, replicating a known risk locus. Simulation results indicate that the method can yield over 96% reduction in genotyping. Our method is implemented as a Java program called AAAmap and is freely available.
Chatzi, L; Rifas-Shiman, S L; Georgiou, V; Joung, K E; Koinaki, S; Chalkiadaki, G; Margioris, A; Sarri, K; Vassilaki, M; Vafeiadi, M; Kogevinas, M; Mantzoros, C; Gillman, M W; Oken, E
2017-08-01
In adults, adherence to the Mediterranean diet has been inversely associated with cardiovascular risk, but the extent to which diet in pregnancy is associated with offspring adiposity is unclear. We aimed to investigate the association between adherence to Mediterranean diet in pregnancy and offspring cardiometabolic traits in two pregnancy cohorts. We studied 997 mother-child pairs from Project Viva in Massachusetts, USA, and 569 pairs from the Rhea study in Crete, Greece. We estimated adherence to the Mediterranean diet with an a priori defined score (MDS) of nine foods and nutrients (0 to 9). We measured child weight, height, waist circumference, skin-fold thicknesses, blood pressure, and blood levels of lipids, c-reactive protein and adipokines in mid-childhood (median 7.7 years) in Viva, and in early childhood (median 4.2 years) in Rhea. We calculated cohort-specific effects and pooled effects estimates with random-effects models for cohort and child age. In Project Viva, the mean (SD, standard deviation) MDS was 2.7 (1.6); in Rhea it was 3.8 (1.7). In the pooled analysis, for each 3-point increment in the MDS, offspring BMI z-score was lower by 0.14 units (95% CI, -0.15 to -0.13), waist circumference by 0.39 cm (95% CI, -0.64 to -0.14), and the sum of skin-fold thicknesses by 0.63 mm (95% CI, -0.98 to -0.28). We also observed lower offspring systolic (-1.03 mmHg; 95% CI, -1.65 to -0.42) and diastolic blood pressure (-0.57 mmHg; 95% CI, -0.98 to -0.16). Greater adherence to Mediterranean diet during pregnancy may protect against excess offspring cardiometabolic risk. © 2017 World Obesity Federation.
Carreiro, Marina Pimenta; Lauria, Márcio W; Naves, Gabriel Nino T; Miranda, Paulo Augusto C; Leite, Ricardo Barsaglini; Rajão, Kamilla Maria Araújo Brandão; de Aguiar, Regina Amélia Lopes Pessoa; Nogueira, Anelise Impeliziere; Ribeiro-Oliveira, Antônio
2016-09-01
To study glucose profiles of gestational diabetes (GDM) patients with 72 h of continuous glucose monitoring (CGM) either before (GDM1) or after (GDM2) dietary counseling, comparing them with nondiabetic (NDM) controls. We performed CGM on 22 GDM patients; 11 before and 11 after dietary counseling and compared them to 11 healthy controls. Several physiological and clinical characteristics of the glucose profiles were compared across the groups, including comparisons for pooled 24-h measures and hourly median values, summary measures representing glucose exposure (area under the median curves) and variability (amplitude, standard deviation, interquartile range), and time points related to meals. Most women (81.8%) in the GDM groups had fasting glucose <95mg/dL, suggesting mild GDM. Variability, glucose levels 1 and 2h after breakfast and dinner, peak values after dinner and glucose levels between breakfast and lunch, were all significantly higher in GDM1 than NDM (P<0.05 for all comparisons). The GDM2 results were similar to NDM in all aforementioned comparisons (P>0.05). Both GDM groups spent more time with glucose levels above 140mg/dL when compared with the NDM group. No differences among the groups were found for: pooled measurements and hourly comparisons, exposure, nocturnal, fasting, between lunch and dinner and before meals, as well as after lunch (P>0.05 for all). The main differences between the mild GDM1 group and healthy controls were related to glucose variability and excursions above 140mg/dL, while glucose exposure was similar. Glucose levels after breakfast and dinner also discerned the GDM1 group. Dietary counseling was able to keep glucose levels to those of healthy patients. © 2016 European Society of Endocrinology.
Tracking the course of the manufacturing process in selective laser melting
NASA Astrophysics Data System (ADS)
Thombansen, U.; Gatej, A.; Pereira, M.
2014-02-01
An innovative optical train for a selective laser melting based manufacturing system (SLM) has been designed under the objective to track the course of the SLM process. In this, the thermal emission from the melt pool and the geometric properties of the interaction zone are addressed by applying a pyrometer and a camera system respectively. The optical system is designed such that all three radiations from processing laser, thermal emission and camera image are coupled coaxially and that they propagate on the same optical axis. As standard f-theta lenses for high power applications inevitably lead to aberrations and divergent optical axes for increasing deflection angles in combination with multiple wavelengths, a pre-focus system is used to implement a focusing unit which shapes the beam prior to passing the scanner. The sensor system records synchronously the current position of the laser beam, the current emission from the melt pool and an image of the interaction zone. Acquired data of the thermal emission is being visualized after processing which allows an instant evaluation of the course of the process at any position of each layer. As such, it provides a fully detailed history of the product This basic work realizes a first step towards self-optimization of the manufacturing process by providing information about quality relevant events during manufacture. The deviation from the planned course of the manufacturing process to the actual course of the manufacturing process can be used to adapt the manufacturing strategy from one layer to the next. In the current state, the system can be used to facilitate the setup of the manufacturing system as it allows identification of false machine settings without having to analyze the work piece.
Ipek, M; Ipek, A; Seker, M; Gul, M K
2015-03-27
The purpose of this research was to characterize an olive core collection using some agronomic characters and simple sequence repeat (SSR) markers and to determine SSR markers associated with the content of fatty acids in olive oil. SSR marker analysis demonstrated the presence of a high amount of genetic variation between the olive cultivars analyzed. A UPGMA dendrogram demonstrated that olive cultivars did not cluster on the basis of their geographic origin. Fatty acid components of olive oil in these cultivars were determined. The results also showed that there was a great amount of variation between the olive cultivars in terms of fatty acid composition. For example, oleic acid content ranged from 57.76 to 76.9% with standard deviation of 5.10%. Significant correlations between fatty acids of olive oil were observed. For instance, a very high negative correlation (-0.812) between oleic and linoleic acids was detected. A structured association analysis between the content of fatty acids in olive oil and SSR markers was performed. STRUCTURE analysis assigned olive cultivars to two gene pools (K = 2). Assignment of olive cultivars to these gene pools was not based on geographical origin. Association between fatty acid traits and SSR markers was evaluated using the general linear model of TASSEL. Significant associations were determined between five SSR markers and stearic, oleic, linoleic, and linolenic acids of olive oil. Very high associations (P < 0.001) between ssrOeUA-DCA14 and stearic acid and between GAPU71B and oleic acid indicated that these markers could be used for marker-assisted selection in olive.
Determining the Equation of State (EoS) Parameters for Ballistic Gelatin
2015-09-01
standard deviation. The specific heat measured at room temperature reported in (Winter 1975) is approximately 1.13 cal/g/°C (= 4.73 J /g/K). Fig. 4...Piatt 2010) Table 3 Specific heat capacity, average heat capacity, and standard deviation Temperature (°C) Cp [ J /(g·K)] Cp Cp Cp Average Cp...density amorphous ice and their implications on pressure induced amorphization. J Chem Physics. 2005;122:124710. Appleby-Thomas GJ, Hazell PJ
Precision Geolocation of Active Electromagnetic Sensors Using Stationary Magnetic Sensors
2009-09-01
0.0003, 0.0003 ] m TiltMeter Mean Pitch: -1.71576990 and Roll: 0.92591697 LSQ Moment Pitch: 0.00576850 and Roll: -0.35543026 Run #5...Standard deviation of optimized solution: [ 0.0028, 0.0014, 0.0012 ] m TiltMeter Mean Pitch: -1.08757549 and Roll: 1.09065730 LSQ Moment...0.00, 0.00, -434.95 ] Standard deviation of optimized solution: [ 0.0051, 0.0031, 0.0035 ] m TiltMeter Mean Pitch: 0.05301905
Coherent and Semiclassical States of a Charged Particle in a Constant Electric Field
NASA Astrophysics Data System (ADS)
Adorno, T. C.; Pereira, A. S.
2018-05-01
The method of integrals of motion is used to construct families of generalized coherent states of a nonrelativistic spinless charged particle in a constant electric field. Families of states, differing in the values of their standard deviations at the initial time, are obtained. Depending on the initial values of the standard deviations, and also on the electric field, it turns out to be possible to identify some families with semiclassical states.
An estimator for the standard deviation of a natural frequency. I.
NASA Technical Reports Server (NTRS)
Schiff, A. J.; Bogdanoff, J. L.
1971-01-01
A brief review of mean-square approximate systems is given. The case in which the masses are deterministic is considered first in the derivation of an estimator for the upper bound of the standard deviation of a natural frequency. Two examples presented include a two-degree-of-freedom system and a case in which the disorder in the springs is perfectly correlated. For purposes of comparison, a Monte Carlo simulation was done on a digital computer.
Is Survival Better at Hospitals With Higher “End-of-Life” Treatment Intensity?
Barnato, Amber E.; Chang, Chung-Chou H.; Farrell, Max H.; Lave, Judith R.; Roberts, Mark S.; Angus, Derek C.
2013-01-01
Background Concern regarding wide variations in spending and intensive care unit use for patients at the end of life hinges on the assumption that such treatment offers little or no survival benefit. Objective To explore the relationship between hospital “end-of-life” (EOL) treatment intensity and postadmission survival. Research Design Retrospective cohort analysis of Pennsylvania Health Care Cost Containment Council discharge data April 2001 to March 2005 linked to vital statistics data through September 2005 using hospital-level correlation, admission-level marginal structural logistic regression, and pooled logistic regression to approximate a Cox survival model. Subjects A total of 1,021,909 patients ≥65 years old, incurring 2,216,815 admissions in 169 Pennsylvania acute care hospitals. Measures EOL treatment intensity (a summed index of standardized intensive care unit and life-sustaining treatment use among patients with a high predicted probability of dying [PPD] at admission) and 30- and 180-day postadmission mortality. Results There was a nonlinear negative relationship between hospital EOL treatment intensity and 30-day mortality among all admissions, although patients with higher PPD derived the greatest benefit. Compared with admission at an average intensity hospital, admission to a hospital 1 standard deviation below versus 1 standard deviation above average intensity resulted in an adjusted odds ratio of mortality for admissions at low PPD of 1.06 (1.04–1.08) versus 0.97 (0.96–0.99); average PPD: 1.06 (1.04–1.09) versus 0.97 (0.96–0.99); and high PPD: 1.09 (1.07–1.11) versus 0.97 (0.95– 0.99), respectively. By 180 days, the benefits to intensity attenuated (low PPD: 1.03 [1.01–1.04] vs. 1.00 [0.98–1.01]; average PPD: 1.03 [1.02–1.05] vs. 1.00 [0.98–1.01]; and high PPD: 1.06 [1.04–1.09] vs. 1.00 [0.98–1.02]), respectively. Conclusions Admission to higher EOL treatment intensity hospitals is associated with small gains in postadmission survival. The marginal returns to intensity diminish for admission to hospitals above average EOL treatment intensity and wane with time. PMID:20057328
NASA Astrophysics Data System (ADS)
Huang, Dong; Campos, Edwin; Liu, Yangang
2014-09-01
Statistical characteristics of cloud variability are examined for their dependence on averaging scales and best representation of probability density function with the decade-long retrieval products of cloud liquid water path (LWP) from the tropical western Pacific (TWP), Southern Great Plains (SGP), and North Slope of Alaska (NSA) sites of the Department of Energy's Atmospheric Radiation Measurement Program. The statistical moments of LWP show some seasonal variation at the SGP and NSA sites but not much at the TWP site. It is found that the standard deviation, relative dispersion (the ratio of the standard deviation to the mean), and skewness all quickly increase with the averaging window size when the window size is small and become more or less flat when the window size exceeds 12 h. On average, the cloud LWP at the TWP site has the largest values of standard deviation, relative dispersion, and skewness, whereas the NSA site exhibits the least. Correlation analysis shows that there is a positive correlation between the mean LWP and the standard deviation. The skewness is found to be closely related to the relative dispersion with a correlation coefficient of 0.6. The comparison further shows that the lognormal, Weibull, and gamma distributions reasonably explain the observed relationship between skewness and relative dispersion over a wide range of scales.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Dong; Campos, Edwin; Liu, Yangang
2014-09-17
Statistical characteristics of cloud variability are examined for their dependence on averaging scales and best representation of probability density function with the decade-long retrieval products of cloud liquid water path (LWP) from the tropical western Pacific (TWP), Southern Great Plains (SGP), and North Slope of Alaska (NSA) sites of the Department of Energy’s Atmospheric Radiation Measurement Program. The statistical moments of LWP show some seasonal variation at the SGP and NSA sites but not much at the TWP site. It is found that the standard deviation, relative dispersion (the ratio of the standard deviation to the mean), and skewness allmore » quickly increase with the averaging window size when the window size is small and become more or less flat when the window size exceeds 12 h. On average, the cloud LWP at the TWP site has the largest values of standard deviation, relative dispersion, and skewness, whereas the NSA site exhibits the least. Correlation analysis shows that there is a positive correlation between the mean LWP and the standard deviation. The skewness is found to be closely related to the relative dispersion with a correlation coefficient of 0.6. The comparison further shows that the log normal, Weibull, and gamma distributions reasonably explain the observed relationship between skewness and relative dispersion over a wide range of scales.« less
Oberg, K.A.; Schmidt, A.R.
1994-01-01
A total of 213 measurements of leakage were made at three control structures near Chicago, Ill.--the Chicago River Controlling Works (CRCW), Thomas J. O'Brien Lock and Dam (O'Brien), and Wilmette Pumping Station (Wilmette)--using acoustic Doppler current profilers (ADCP's) and dye-dilution techniques. The CRCW consists of the Chicago Lock and two sets of sluice gates connected by a network of harbor walls. Leakage measurements were made in April, May, July, September, and October 1993 using an ADCP. The mean and standard deviation of leakage measured by the ADCP for the Chicago Lock river gate were 133 and 39 cubic feet per second, respectively. The mean and standard deviation of the leakage measurements at CRCW were 204 and 70 cubic feet per second, respectively. The mean and standard deviation of leakage measurements at O'Brien on September 17, 1993, were 21 and 10 cubic feet per second, respectively. The mean and standard deviation leakage measured at Wilmette using the ADCP were 59 and 8 cubic feet per second, respectively, in April 1993. After the pump bays at Wilmette were sealed in July 1993, the leakage dropped to less than 15 cubic feet per second in September 1993. Discharge estimated by dye-dilution at the Chicago Lock on July 15, 1993, was 160 cubic feet per second, or within 8 percent of the discharge measured with the ADCP. (USGS)
Hazardous Traffic Event Detection Using Markov Blanket and Sequential Minimal Optimization (MB-SMO)
Yan, Lixin; Zhang, Yishi; He, Yi; Gao, Song; Zhu, Dunyao; Ran, Bin; Wu, Qing
2016-01-01
The ability to identify hazardous traffic events is already considered as one of the most effective solutions for reducing the occurrence of crashes. Only certain particular hazardous traffic events have been studied in previous studies, which were mainly based on dedicated video stream data and GPS data. The objective of this study is twofold: (1) the Markov blanket (MB) algorithm is employed to extract the main factors associated with hazardous traffic events; (2) a model is developed to identify hazardous traffic event using driving characteristics, vehicle trajectory, and vehicle position data. Twenty-two licensed drivers were recruited to carry out a natural driving experiment in Wuhan, China, and multi-sensor information data were collected for different types of traffic events. The results indicated that a vehicle’s speed, the standard deviation of speed, the standard deviation of skin conductance, the standard deviation of brake pressure, turn signal, the acceleration of steering, the standard deviation of acceleration, and the acceleration in Z (G) have significant influences on hazardous traffic events. The sequential minimal optimization (SMO) algorithm was adopted to build the identification model, and the accuracy of prediction was higher than 86%. Moreover, compared with other detection algorithms, the MB-SMO algorithm was ranked best in terms of the prediction accuracy. The conclusions can provide reference evidence for the development of dangerous situation warning products and the design of intelligent vehicles. PMID:27420073
Javidi, Bahram; Markman, Adam; Rawat, Siddharth; O'Connor, Timothy; Anand, Arun; Andemariam, Biree
2018-05-14
We present a spatio-temporal analysis of cell membrane fluctuations to distinguish healthy patients from patients with sickle cell disease. A video hologram containing either healthy red blood cells (h-RBCs) or sickle cell disease red blood cells (SCD-RBCs) was recorded using a low-cost, compact, 3D printed shearing interferometer. Reconstructions were created for each hologram frame (time steps), forming a spatio-temporal data cube. Features were extracted by computing the standard deviations and the mean of the height fluctuations over time and for every location on the cell membrane, resulting in two-dimensional standard deviation and mean maps, followed by taking the standard deviations of these maps. The optical flow algorithm was used to estimate the apparent motion fields between subsequent frames (reconstructions). The standard deviation of the magnitude of the optical flow vectors across all frames was then computed. In addition, seven morphological cell (spatial) features based on optical path length were extracted from the cells to further improve the classification accuracy. A random forest classifier was trained to perform cell identification to distinguish between SCD-RBCs and h-RBCs. To the best of our knowledge, this is the first report of machine learning assisted cell identification and diagnosis of sickle cell disease based on cell membrane fluctuations and morphology using both spatio-temporal and spatial analysis.
NASA Astrophysics Data System (ADS)
Lee, Hyun Jeong; Yea, Ji Woon; Oh, Se An
2015-07-01
Respiratory-gated radiation therapy (RGRT) has been used to minimize the dose to normal tissue in lung-cancer radiotherapy. The present research aims to improve the regularity of respiration in RGRT by using a video-coached respiration guiding system. In the study, 16 patients with lung cancer were evaluated. The respiration signals of the patients were measured by using a realtime position management (RPM) respiratory gating system (Varian, USA), and the patients were trained using the video-coaching respiration guiding system. The patients performed free breathing and guided breathing, and the respiratory cycles were acquired for ~5 min. Then, Microsoft Excel 2010 software was used to calculate the mean and the standard deviation for each phase. The standard deviation was computed in order to analyze the improvement in the respiratory regularity with respect to the period and the displacement. The standard deviation of the guided breathing decreased to 48.8% in the inhale peak and 24.2% in the exhale peak compared with the values for the free breathing of patient 6. The standard deviation of the respiratory cycle was found to be decreased when using the respiratory guiding system. The respiratory regularity was significantly improved when using the video-coaching respiration guiding system. Therefore, the system is useful for improving the accuracy and the efficiency of RGRT.
Hazardous Traffic Event Detection Using Markov Blanket and Sequential Minimal Optimization (MB-SMO).
Yan, Lixin; Zhang, Yishi; He, Yi; Gao, Song; Zhu, Dunyao; Ran, Bin; Wu, Qing
2016-07-13
The ability to identify hazardous traffic events is already considered as one of the most effective solutions for reducing the occurrence of crashes. Only certain particular hazardous traffic events have been studied in previous studies, which were mainly based on dedicated video stream data and GPS data. The objective of this study is twofold: (1) the Markov blanket (MB) algorithm is employed to extract the main factors associated with hazardous traffic events; (2) a model is developed to identify hazardous traffic event using driving characteristics, vehicle trajectory, and vehicle position data. Twenty-two licensed drivers were recruited to carry out a natural driving experiment in Wuhan, China, and multi-sensor information data were collected for different types of traffic events. The results indicated that a vehicle's speed, the standard deviation of speed, the standard deviation of skin conductance, the standard deviation of brake pressure, turn signal, the acceleration of steering, the standard deviation of acceleration, and the acceleration in Z (G) have significant influences on hazardous traffic events. The sequential minimal optimization (SMO) algorithm was adopted to build the identification model, and the accuracy of prediction was higher than 86%. Moreover, compared with other detection algorithms, the MB-SMO algorithm was ranked best in terms of the prediction accuracy. The conclusions can provide reference evidence for the development of dangerous situation warning products and the design of intelligent vehicles.
Liang, Xue; Ji, Hai-yan; Wang, Peng-xin; Rao, Zhen-hong; Shen, Bing-hui
2010-01-01
Preprocess method of multiplicative scatter correction (MSC) was used to reject noises in the original spectra produced by the environmental physical factor effectively, then the principal components of near-infrared spectroscopy were calculated by nonlinear iterative partial least squares (NIPALS) before building the back propagation artificial neural networks method (BP-ANN), and the numbers of principal components were calculated by the method of cross validation. The calculated principal components were used as the inputs of the artificial neural networks model, and the artificial neural networks model was used to find the relation between chlorophyll in winter wheat and reflective spectrum, which can predict the content of chlorophyll in winter wheat. The correlation coefficient (r) of calibration set was 0.9604, while the standard deviation (SD) and relative standard deviation (RSD) was 0.187 and 5.18% respectively. The correlation coefficient (r) of predicted set was 0.9600, and the standard deviation (SD) and relative standard deviation (RSD) was 0.145 and 4.21% respectively. It means that the MSC-ANN algorithm can reject noises in the original spectra produced by the environmental physical factor effectively and set up an exact model to predict the contents of chlorophyll in living leaves veraciously to replace the classical method and meet the needs of fast analysis of agricultural products.
Professionalism in medical students at a private medical college in Karachi, Pakistan.
Sobani, Zain-ul-abedeen; Mohyuddin, Muhammad Masaud; Farooq, Fahd; Qaiser, Kanza Noor; Gani, Faiz; Bham, Nida Shahab; Raheem, Ahmed; Mehraj, Vikram; Saeed, Syed Abdul; Sharif, Hasanat; Sheerani, Mughis; Zuberi, Rukhsana Wamiq; Beg, Mohamamd Asim
2013-07-01
To determine levels of professionalism in undergraduate medical students at a private medical college and assess how changes emerge during their training. The study was conducted at Aga Khan University, a tertiary care teaching hospital, during November and December 2011. Freshmen, Year 3 and Year 5 students were requested to fill out a questionnaire. It was designed to assess the participants' levels of professionalism and how they perceived the professional environment around them by incorporating previously described scales. The questionnaire was re-validated on a random sample of practising clinicians at the same hospital. SPSS 17 was used for statistical analysis. The study sample comprised 204 participants. The mean score for level of individual professionalism was 7.72+/-3.43. Only 13 (6.4%) students had a score one standard deviation above the faculty mean. About 24 (11.8%) were one standard deviation and 35 (17.2%) were 2 standard deviations below the faculty mean. The remaining 130 (63.7%) were >2 standard deviations below the faculty mean. Considering the level of education, the mean score for level of professionalism was 8.00+/-3.39 for freshmen, 6.85+/-3.41 for year 3 students, and 8.40+/-3.34 for year 5 students. The currently employed teaching practices inculcating the values of professionalism in medical students are serving as a buffer to maintain the pre-training levels of professionalism from declining.
Pratt, Kenneth W
2015-04-01
This meta-analysis assesses the long-term (up to 70 years) within-laboratory variation of the NIST pH Standard Reference Material® (SRM) tetroxalate, phthalate, phosphate, borate, and carbonate buffers. Values of ΔpH(S), the difference between the certified pH value, pH(S), of each SRM issue and the mean of all pH(S) values for the given SRM at that Celsius temperature, t, are graphed as a function of the SRM issue and t. In most cases, |ΔpH(S)| < 0.004. Deviations from the nominal base:acid amount (mole) ratio of a buffer yield t-independent, constant shifts in ΔpH(S). The mean ΔpH(S) characterizes such deviations. The corresponding mole fraction of impurity in the conjugate buffer component is generally <0.3 %. Changes in the equipment, personnel, materials, and methodology of the pH(S) measurement yield t-dependent variations. The standard deviation of ΔpH(S) characterizes such changes. Standard deviations of ΔpH(S) are generally 0.0015 or less. The results provide a long-term, single-institution complement to the time-specific, multi-institution results of pH key comparisons administered by the Consultative Committee for Metrology in Chemistry and Biology (CCQM).
Evaluation of a Brief Intervention Designed to Increase CPR Training among Pregnant Pool Owners
ERIC Educational Resources Information Center
Girasek, Deborah C.
2011-01-01
This study evaluated whether a brief videotape could motivate pregnant pool owners to be trained in infant/child cardiopulmonary resuscitation (CPR). Women were recruited from prenatal classes in South Florida. Eligible volunteers were randomized to view a video or receive standard treatment, after completing a questionnaire. The video explained…
78 FR 63915 - New Mailing Standards for Domestic Mailing Services Products
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-25
... locations. In addition, preparing FSS scheme pallets allows for the creation of larger pallets, which...-digit FSS scheme pools when addressed for delivery to any FSS 5-digit scheme combination per labeling... into a separate pool for each individual 5-digit FSS-scheme combination. Mailings that include 10 or...
48 CFR 9904.410-63 - Effective date.
Code of Federal Regulations, 2013 CFR
2013-10-01
...: (a) Contract I—Since Contract I was in existence prior to January 1, 1978, the G&A expense pool shall... this contract was in existence prior to January 1, 1978, the G&A expense pool shall be allocated to it..., 1992. Contractors with prior CAS-covered contracts with full coverage shall continue this Standard's...
Swimming Pool Water Treatment Chemicals and/or Processes. Standard No. 22.
ERIC Educational Resources Information Center
National Sanitation Foundation, Ann Arbor, MI.
Chemicals or processes used or intended for use, in the treatment of swimming pool water are covered. Minimum public health limits or acceptability in regard to toxicity, biocidal effectiveness, and chemical behavior and analysis are presented. The appendices give guidelines to the scientific and statistically sound evaluations to determine the…
Sample size determination in combinatorial chemistry.
Zhao, P L; Zambias, R; Bolognese, J A; Boulton, D; Chapman, K
1995-01-01
Combinatorial chemistry is gaining wide appeal as a technique for generating molecular diversity. Among the many combinatorial protocols, the split/recombine method is quite popular and particularly efficient at generating large libraries of compounds. In this process, polymer beads are equally divided into a series of pools and each pool is treated with a unique fragment; then the beads are recombined, mixed to uniformity, and redivided equally into a new series of pools for the subsequent couplings. The deviation from the ideal equimolar distribution of the final products is assessed by a special overall relative error, which is shown to be related to the Pearson statistic. Although the split/recombine sampling scheme is quite different from those used in analysis of categorical data, the Pearson statistic is shown to still follow a chi2 distribution. This result allows us to derive the required number of beads such that, with 99% confidence, the overall relative error is controlled to be less than a pregiven tolerable limit L1. In this paper, we also discuss another criterion, which determines the required number of beads so that, with 99% confidence, all individual relative errors are controlled to be less than a pregiven tolerable limit L2 (0 < L2 < 1). PMID:11607586
Mavilio, Alberto; Sisto, Dario; Ferreri, Paolo; Cardascia, Nicola; Alessio, Giovanni
2017-01-01
A significant variability of the second harmonic (2ndH) phase of steady-state pattern electroretinogram (SS-PERG) in intrasession retest has been recently described in glaucoma patients (GP), which has not been found in healthy subjects. To evaluate the reliability of phase variability in retest (a procedure called RE-PERG or REPERG) in the presence of cataract, which is known to affect standard PERG, we tested this procedure in GP, normal controls (NC), and cataract patients (CP). The procedure was performed on 50 GP, 35 NC, and 27 CP. All subjects were examined with RE-PERG and SS-PERG and also with spectral domain optical coherence tomography and standard automated perimetry. Standard deviation of phase and amplitude value of 2ndH were correlated by means of one-way analysis of variance and Pearson correlation, with the mean deviation and pattern standard deviation assessed by standard automated perimetry and retinal nerve fiber layer and the ganglion cell complex thickness assessed by spectral domain optical coherence tomography. Receiver operating characteristics were calculated in cohort populations with and without cataract. Standard deviation of phase of 2ndH was significantly higher in GP with respect to NC ( P <0.001) and CP ( P <0.001), and it correlated with retinal nerve fiber layer ( r =-0.5, P <0.001) and ganglion cell complex ( r =-0.6, P <0.001) defects in GP. Receiver operating characteristic evaluation showed higher specificity of RE-PERG (86.4%; area under the curve 0.93) with respect to SS-PERG (54.5%; area under the curve 0.68) in CP. RE-PERG may improve the specificity of SS-PERG in clinical practice in the discrimination of GP.
Sarikouch, Samir; Boethig, Dietmar; Peters, Brigitte; Kropf, Siegfried; Dubowy, Karl-Otto; Lange, Peter; Kuehne, Titus; Haverich, Axel; Beerbaum, Philipp
2013-11-01
In repaired congenital heart disease, there is increasing evidence of sex differences in cardiac remodeling, but there is a lack of comparable data for specific congenital heart defects such as in repaired tetralogy of Fallot. In a prospective multicenter study, a cohort of 272 contemporary patients (158 men; mean age, 14.3±3.3 years [range, 8-20 years]) with repaired tetralogy of Fallot underwent cardiac magnetic resonance for ventricular function and metabolic exercise testing. All data were transformed to standard deviation scores according to the Lambda-Mu-Sigma method by relating individual values to their respective 50th percentile (standard deviation score, 0) in sex-specific healthy control subjects. No sex differences were observed in age at repair, type of repair conducted, or overall hemodynamic results. Relative to sex-specific controls, repaired tetralogy of Fallot in women had larger right ventricular end-systolic volumes (standard deviation scores: women, 4.35; men, 3.25; P=0.001), lower right ventricular ejection fraction (women, -2.83; men, -2.12; P=0.011), lower right ventricular muscle mass (women, 1.58; men 2.45; P=0.001), poorer peak oxygen uptake (women, -1.65; men, -1.14; P<0.001), higher VE/VCO2 (ventilation per unit of carbon dioxide production) slopes (women, 0.88; men 0.58; P=0.012), and reduced peak heart rate (women, -2.16; men -1.74; P=0.017). Left ventricular parameters did not differ between sexes. Relative to their respective sex-specific healthy control subjects, derived standard deviation scores in repaired tetralogy of Fallot suggest that women perform poorer than men in terms of right ventricular systolic function as tested by cardiac magnetic resonance and exercise capacity. This effect cannot be explained by selection bias. Further outcome data are required from longitudinal cohort studies.
Mehta, Amar J.; Kloog, Itai; Zanobetti, Antonella; Coull, Brent A.; Sparrow, David; Vokonas, Pantel; Schwartz, Joel
2014-01-01
Background The underlying mechanisms of the association between ambient temperature and cardiovascular morbidity and mortality are not well understood, particularly for daily temperature variability. We evaluated if daily mean temperature and standard deviation of temperature was associated with heart rate-corrected QT interval (QTc) duration, a marker of ventricular repolarization in a prospective cohort of older men. Methods This longitudinal analysis included 487 older men participating in the VA Normative Aging Study with up to three visits between 2000–2008 (n = 743). We analyzed associations between QTc and moving averages (1–7, 14, 21, and 28 days) of the 24-hour mean and standard deviation of temperature as measured from a local weather monitor, and the 24-hour mean temperature estimated from a spatiotemporal prediction model, in time-varying linear mixed-effect regression. Effect modification by season, diabetes, coronary heart disease, obesity, and age was also evaluated. Results Higher mean temperature as measured from the local monitor, and estimated from the prediction model, was associated with longer QTc at moving averages of 21 and 28 days. Increased 24-hr standard deviation of temperature was associated with longer QTc at moving averages from 4 and up to 28 days; a 1.9°C interquartile range increase in 4-day moving average standard deviation of temperature was associated with a 2.8 msec (95%CI: 0.4, 5.2) longer QTc. Associations between 24-hr standard deviation of temperature and QTc were stronger in colder months, and in participants with diabetes and coronary heart disease. Conclusion/Significance In this sample of older men, elevated mean temperature was associated with longer QTc, and increased variability of temperature was associated with longer QTc, particularly during colder months and among individuals with diabetes and coronary heart disease. These findings may offer insight of an important underlying mechanism of temperature-related cardiovascular morbidity and mortality in an older population. PMID:25238150
Ma, Jiantao; Karlsen, Micaela C; Chung, Mei; Jacques, Paul F; Saltzman, Edward; Smith, Caren E; Fox, Caroline S; McKeown, Nicola M
2016-01-01
The effect of added sugar intake on ectopic fat accumulation is a subject of debate. A systematic review and meta-analysis of randomized controlled trials (RCTs) was conducted to examine the potential effect of added sugar intake on ectopic fat depots. MEDLINE, CAB Abstracts, CAB Global Health, and EBM (Evidence-Based Medicine) Reviews - Cochrane Central Register of Controlled Trials databases were searched for studies published from 1973 to September 2014. RCTs with a minimum of 6 days' duration of added sugar exposure in the intervention group were selected. The dosage of added sugar intake as a percentage of total energy was extracted or calculated. Means and standard deviations of pre- and post-test measurements or changes in ectopic fat depots were collected. Fourteen RCTs were included. Most of the studies had a medium to high risk of bias. Meta-analysis showed that, compared with eucaloric controls, subjects who consumed added sugar under hypercaloric conditions likely increased ectopic fat, particularly in the liver (pooled standardized mean difference = 0.9 [95%CI, 0.6-1.2], n = 6) and muscles (pooled SMD = 0.6 [95%CI, 0.2-1.0], n = 4). No significant difference was observed in liver fat, visceral adipose tissue, or muscle fat when isocaloric intakes of different sources of added sugars were compared. Data from a limited number of RCTs suggest that excess added sugar intake under hypercaloric diet conditions likely increases ectopic fat depots, particularly in the liver and in muscle fat. There are insufficient data to compare the effect of different sources of added sugars on ectopic fat deposition or to compare intake of added sugar with intakes of other macronutrients. Future well-designed RCTs with sufficient power and duration are needed to address the role of sugars on ectopic fat deposition. © The Author(s) 2015. Published by Oxford University Press on behalf of the International Life Sciences Institute. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Method and reporting quality in health professions education research: a systematic review.
Cook, David A; Levinson, Anthony J; Garside, Sarah
2011-03-01
Studies evaluating reporting quality in health professions education (HPE) research have demonstrated deficiencies, but none have used comprehensive reporting standards. Additionally, the relationship between study methods and effect size (ES) in HPE research is unknown. This review aimed to evaluate, in a sample of experimental studies of Internet-based instruction, the quality of reporting, the relationship between reporting and methodological quality, and associations between ES and study methods. We conducted a systematic search of databases including MEDLINE, Scopus, CINAHL, EMBASE and ERIC, for articles published during 1990-2008. Studies (in any language) quantifying the effect of Internet-based instruction in HPE compared with no intervention or other instruction were included. Working independently and in duplicate, we coded reporting quality using the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement, and coded study methods using a modified Newcastle-Ottawa Scale (m-NOS), the Medical Education Research Study Quality Instrument (MERSQI), and the Best Evidence in Medical Education (BEME) global scale. For reporting quality, articles scored a mean±standard deviation (SD) of 51±25% of STROBE elements for the Introduction, 58±20% for the Methods, 50±18% for the Results and 41±26% for the Discussion sections. We found positive associations (all p<0.0001) between reporting quality and MERSQI (ρ=0.64), m-NOS (ρ=0.57) and BEME (ρ=0.58) scores. We explored associations between study methods and knowledge ES by subtracting each study's ES from the pooled ES for studies using that method and comparing these differences between subgroups. Effect sizes in single-group pretest/post-test studies differed from the pooled estimate more than ESs in two-group studies (p=0.013). No difference was found between other study methods (yes/no: representative sample, comparison group from same community, randomised, allocation concealed, participants blinded, assessor blinded, objective assessment, high follow-up). Information is missing from all sections of reports of HPE experiments. Single-group pre-/post-test studies may overestimate ES compared with two-group designs. Other methodological variations did not bias study results in this sample. © Blackwell Publishing Ltd 2011.
Mohd Yusof, Mohd Yusmiaidil Putera; Wan Mokhtar, Ilham; Rajasekharan, Sivaprakash; Overholser, Rosanna; Martens, Luc
2017-11-01
Through numerous validation and method comparison studies on different populations, the Willems method exhibited a superior accuracy. This article aims to systematically examine how accurate the application of Willems dental age method on children of different age groups and its performance based on various populations and regions. A strategic literature search of PubMed, MEDLINE, Web of Science, EMBASE and hand searching were used to identify the studies published up to September 2014 that estimated the dental age using the Willems method (modified Demirjian), with a populations, intervention, comparisons and outcomes (PICO) search strategy using MeSH keywords, focusing on the question: How much Willems method deviates from the chronological age in estimating age in children? Standardized mean differences were calculated for difference of dental age to chronological age by using random effects model. Subgroup analyses were performed to evaluate potential heterogeneity. Of 116 titles retrieved based on the standardized search strategy, only 19 articles fulfilled the inclusion criteria for quantitative analysis. The pooled estimates were separately kept as underestimation (n=7) and overestimation (n=12) of chronological age groups for both genders according to primary studies. On absolute values, females (underestimated by 0.13; 95% CI: 0.09-0.18 and overestimated by 0.27; 95% CI: 0.17-0.36) exhibited better accuracy than males (underestimated by 0.28; 95% CI: 0.14-0.42 and overestimated by 0.33; 95% CI: 0.22-0.44). For comparison purposes, the overall pooled estimate overestimated the age by 0.10 (95% CI: -0.06 to 0.26) and 0.09 (95% CI: -0.09 to 0.19) for males and females, respectively. There was no significant difference between the young and older child in subgroup analysis using omnibus test. The mean age between different regions exhibited no statistically significant. The use of Willems method is appropriate to estimate age in children considering its accuracy among different populations, investigators and age groups. Copyright © 2017 Elsevier B.V. All rights reserved.
An Optical Flow-Based Full Reference Video Quality Assessment Algorithm.
K, Manasa; Channappayya, Sumohana S
2016-06-01
We present a simple yet effective optical flow-based full-reference video quality assessment (FR-VQA) algorithm for assessing the perceptual quality of natural videos. Our algorithm is based on the premise that local optical flow statistics are affected by distortions and the deviation from pristine flow statistics is proportional to the amount of distortion. We characterize the local flow statistics using the mean, the standard deviation, the coefficient of variation (CV), and the minimum eigenvalue ( λ min ) of the local flow patches. Temporal distortion is estimated as the change in the CV of the distorted flow with respect to the reference flow, and the correlation between λ min of the reference and of the distorted patches. We rely on the robust multi-scale structural similarity index for spatial quality estimation. The computed temporal and spatial distortions, thus, are then pooled using a perceptually motivated heuristic to generate a spatio-temporal quality score. The proposed method is shown to be competitive with the state-of-the-art when evaluated on the LIVE SD database, the EPFL Polimi SD database, and the LIVE Mobile HD database. The distortions considered in these databases include those due to compression, packet-loss, wireless channel errors, and rate-adaptation. Our algorithm is flexible enough to allow for any robust FR spatial distortion metric for spatial distortion estimation. In addition, the proposed method is not only parameter-free but also independent of the choice of the optical flow algorithm. Finally, we show that the replacement of the optical flow vectors in our proposed method with the much coarser block motion vectors also results in an acceptable FR-VQA algorithm. Our algorithm is called the flow similarity index.
Chemically modified cellulose paper as a thin film microextraction phase.
Saraji, Mohammad; Farajmand, Bahman
2013-11-01
In this paper, chemically modified cellulose paper was introduced as a novel extracting phase for thin film microextraction (TFME). Different reagents (Octadecyltrichlorosilane, diphenyldichlorosilane, cyclohexyl isocyanate and phenyl isocyanate) were used to modify the cellulose papers. The modified papers were evaluated as a sorbent for the extraction of some synthetic and natural estrogenic hormones (17α-ethynylestradiol, estriol and estradiol) from aqueous samples. Liquid chromatography-fluorescence detection was used for the quantification of the extracted compounds. The cellulose paper modified with phenyl isocyanate showed the best affinity to the target compounds. TEME parameters such as desorption condition, shaking rate, sample ionic strength and extraction time were investigated and optimized. Limit of detections were between 0.05 and 0.23μgL(-1) and relative standard deviations were less than 11.1% under the optimized condition. The calibration curves were obtained in the range of 0.2-100μgL(-1) with a good linearity (r(2)>0.9935). Wastewater, human urine, pool and river water samples were studied as real samples for the evaluation of the method. Relative recoveries were found to be between 75% and 101%. Copyright © 2013 Elsevier B.V. All rights reserved.
Precision gravity studies at Cerro Prieto: a progress report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grannell, R.B.; Kroll, R.C.; Wyman, R.M.
A third and fourth year of precision gravity data collection and reduction have now been completed at the Cerro Prieto geothermal field. In summary, 66 permanently monumented stations were occupied between December and April of 1979 to 1980 and 1980 to 1981 by a LaCoste and Romberg gravity meter (G300) at least twice, with a minimum of four replicate values obtained each time. Station 20 alternate, a stable base located on Cerro Prieto volcano, was used as the reference base for the third year and all the stations were tied to this base, using four to five hour loops. Themore » field data were reduced to observed gravity values by (1) multiplication with the appropriate calibration factor; (2) removal of calculated tidal effects; (3) calculation of average values at each station, and (4) linear removal of accumulated instrumental drift which remained after carrying out the first three reductions. Following the reduction of values and calculation of gravity differences between individual stations and the base stations, standard deviations were calculated for the averaged occupation values (two to three per station). In addition, pooled variance calculations were carried out to estimate precision for the surveys as a whole.« less
NASA Technical Reports Server (NTRS)
Warner, Joseph D.; Theofylaktos, Onoufrios
2012-01-01
A method of determining the bit error rate (BER) of a digital circuit from the measurement of the analog S-parameters of the circuit has been developed. The method is based on the measurement of the noise and the standard deviation of the noise in the S-parameters. Once the standard deviation and the mean of the S-parameters are known, the BER of the circuit can be calculated using the normal Gaussian function.
NASA Astrophysics Data System (ADS)
Anees, Amir; Khan, Waqar Ahmad; Gondal, Muhammad Asif; Hussain, Iqtadar
2013-07-01
The aim of this work is to make use of the mean of absolute deviation (MAD) method for the evaluation process of substitution boxes used in the advanced encryption standard. In this paper, we use the MAD technique to analyze some popular and prevailing substitution boxes used in encryption processes. In particular, MAD is applied to advanced encryption standard (AES), affine power affine (APA), Gray, Lui J., Residue Prime, S8 AES, SKIPJACK, and Xyi substitution boxes.
NASA Technical Reports Server (NTRS)
Anspaugh, B. E.; Miyahira, T. F.; Weiss, R. S.
1979-01-01
Computed statistical averages and standard deviations with respect to the measured cells for each intensity temperature measurement condition are presented. Display averages and standard deviations of the cell characteristics in a two dimensional array format are shown: one dimension representing incoming light intensity, and another, the cell temperature. Programs for calculating the temperature coefficients of the pertinent cell electrical parameters are presented, and postirradiation data are summarized.
Evaluation of Acoustic Doppler Current Profiler measurements of river discharge
Morlock, S.E.
1996-01-01
The standard deviations of the ADCP measurements ranged from approximately 1 to 6 percent and were generally higher than the measurement errors predicted by error-propagation analysis of ADCP instrument performance. These error-prediction methods assume that the largest component of ADCP discharge measurement error is instrument related. The larger standard deviations indicate that substantial portions of measurement error may be attributable to sources unrelated to ADCP electronics or signal processing and are functions of the field environment.
Artes, Paul H; Hutchison, Donna M; Nicolela, Marcelo T; LeBlanc, Raymond P; Chauhan, Balwantray C
2005-07-01
To compare test results from second-generation Frequency-Doubling Technology perimetry (FDT2, Humphrey Matrix; Carl-Zeiss Meditec, Dublin, CA) and standard automated perimetry (SAP) in patients with glaucoma. Specifically, to examine the relationship between visual field sensitivity and test-retest variability and to compare total and pattern deviation probability maps between both techniques. Fifteen patients with glaucoma who had early to moderately advanced visual field loss with SAP (mean MD, -4.0 dB; range, +0.2 to -16.1) were enrolled in the study. Patients attended three sessions. During each session, one eye was examined twice with FDT2 (24-2 threshold test) and twice with SAP (Swedish Interactive Threshold Algorithm [SITA] Standard 24-2 test), in random order. We compared threshold values between FDT2 and SAP at test locations with similar visual field coordinates. Test-retest variability, established in terms of test-retest intervals and standard deviations (SDs), was investigated as a function of visual field sensitivity (estimated by baseline threshold and mean threshold, respectively). The magnitude of visual field defects apparent in total and pattern deviation probability maps were compared between both techniques by ordinal scoring. The global visual field indices mean deviation (MD) and pattern standard deviation (PSD) of FDT2 and SAP correlated highly (r > 0.8; P < 0.001). At test locations with high sensitivity (>25 dB with SAP), threshold estimates from FDT2 and SAP exhibited a close, linear relationship, with a slope of approximately 2.0. However, at test locations with lower sensitivity, the relationship was much weaker and ceased to be linear. In comparison with FDT2, SAP showed a slightly larger proportion of test locations with absolute defects (3.0% vs. 2.2% with SAP and FDT2, respectively, P < 0.001). Whereas SAP showed a significant increase in test-retest variability at test locations with lower sensitivity (P < 0.001), there was no relationship between variability and sensitivity with FDT2 (P = 0.46). In comparison with SAP, FDT2 exhibited narrower test-retest intervals at test locations with lower sensitivity (SAP thresholds <25 dB). A comparison of the total and pattern deviation maps between both techniques showed that the total deviation analyses of FDT2 may slightly underestimate the visual field loss apparent with SAP. However, the pattern-deviation maps of both instruments agreed well with each other. The test-retest variability of FDT2 is uniform over the measurement range of the instrument. These properties may provide advantages for the monitoring of patients with glaucoma that should be investigated in longitudinal studies.
What to use to express the variability of data: Standard deviation or standard error of mean?
Barde, Mohini P; Barde, Prajakt J
2012-07-01
Statistics plays a vital role in biomedical research. It helps present data precisely and draws the meaningful conclusions. While presenting data, one should be aware of using adequate statistical measures. In biomedical journals, Standard Error of Mean (SEM) and Standard Deviation (SD) are used interchangeably to express the variability; though they measure different parameters. SEM quantifies uncertainty in estimate of the mean whereas SD indicates dispersion of the data from mean. As readers are generally interested in knowing the variability within sample, descriptive data should be precisely summarized with SD. Use of SEM should be limited to compute CI which measures the precision of population estimate. Journals can avoid such errors by requiring authors to adhere to their guidelines.
Long-term comparisons between two-way satellite and geodetic time transfer systems.
Plumb, John F; Larson, Kristine M
2005-11-01
Global Positioning System (GPS) observations recorded in the United States and Europe were used to evaluate time transfer capabilities of GETT (geodetic time transfer). Timing estimates were compared with two-way satellite time and frequency transfer (TWSTFT) systems. A comparison of calibrated links at the U.S. Naval Observatory, Washington, D.C., and Colorado Springs, CO, yielded agreement of 2.17 ns over 6 months with a standard deviation of 0.73 ns. An uncalibrated link between the National Institute of Standards and Technology (NIST) and Physikalisch-Technische Bundesanstalt, Braunschweig, Germany, has a standard deviation of 0.79 ns over the same time period.
QED is not endangered by the proton's size
NASA Astrophysics Data System (ADS)
De Rújula, A.
2010-10-01
Pohl et al. have reported a very precise measurement of the Lamb-shift in muonic hydrogen (Pohl et al., 2010) [1], from which they infer the radius characterizing the proton's charge distribution. The result is 5 standard deviations away from the one of the CODATA compilation of physical constants. This has been interpreted (Pohl et al., 2010) [1] as possibly requiring a 4.9 standard-deviation modification of the Rydberg constant, to a new value that would be precise to 3.3 parts in 1013, as well as putative evidence for physics beyond the standard model (Flowers, 2010) [2]. I demonstrate that these options are unsubstantiated.
Test-retest reliability of 3D ultrasound measurements of the thoracic spine.
Fölsch, Christian; Schlögel, Stefanie; Lakemeier, Stefan; Wolf, Udo; Timmesfeld, Nina; Skwara, Adrian
2012-05-01
To explore the reliability of the Zebris CMS 20 ultrasound analysis system with pointer application for measuring end-range flexion, end-range extension, and neutral kyphosis angle of the thoracic spine. The study was performed within the School of Physiotherapy in cooperation with the Orthopedic Department at a University Hospital. The thoracic spines of 28 healthy subjects were measured. Measurements for neutral kyphosis angle, end-range flexion, and end-range extension were taken once at each time point. The bone landmarks were palpated by one examiner and marked with a pointer containing 2 transmitters using a frequency of 40 kHz. A third transmitter was fixed to the pelvis, and 3 microphones were used as receiver. The real angle was calculated by the software. Bland-Altman plots with 95% limits of agreement, intraclass correlations (ICC), standard deviations of mean measurements, and standard error of measurements were used for statistical analyses. The test-retest reliability in this study was measured within a 24-hour interval. Statistical parameters were used to judge reliability. The mean kyphosis angle was 44.8° with a standard deviation of 17.3° at the first measurement and a mean of 45.8° with a standard deviation of 16.2° the following day. The ICC was high at 0.95 for the neutral kyphosis angle, and the Bland-Altman 95% limits of agreement were within clinical acceptable margins. The ICC was 0.71 for end-range flexion and 0.34 for end-range extension, whereas the Bland-Altman 95% limits of agreement were wider than with the static measurement of kyphosis. Compared with static measurements, the analysis of motion with 3-dimensional ultrasound showed an increased standard deviation for test-retest measurements. The test-retest reliability of ultrasound measuring of the neutral kyphosis angle of the thoracic spine was demonstrated within 24 hours. Bland-Altman 95% limits of agreement and the standard deviation of differences did not appear to be clinically acceptable for measuring flexion and extension. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Dispersion y dinamica poblacional
USDA-ARS?s Scientific Manuscript database
Dispersal behavior of fruit flies is appetitive. Measures of dispersion involve two different parameter: the maximum distance and the standard distance. Standard distance is a parameter that describes the probalility of dispersion and is mathematically equivalent to the standard deviation around ...
Development of a Scale to Explore Technology Literacy Skills of Turkish 8th Graders
ERIC Educational Resources Information Center
Misirli, Zeynel A.; Akbulut, Yavuz
2013-01-01
The use of emerging technologies shape learners' knowledge creation and transformation processes. In this regard, this study aimed to develop a scale to investigate 8 th graders' competencies regarding the educational technology standards based on ISTE-NETS. After a review of relevant literature, an item pool was prepared. The pool was improved…
Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik
2016-11-01
To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.
Evaluating Silent Reading Performance with an Eye Tracking System in Patients with Glaucoma
Murata, Noriaki; Fukuchi, Takeo
2017-01-01
Objective To investigate the relationship between silent reading performance and visual field defects in patients with glaucoma using an eye tracking system. Methods Fifty glaucoma patients (Group G; mean age, 52.2 years, standard deviation: 11.4 years) and 20 normal controls (Group N; mean age, 46.9 years; standard deviation: 17.2 years) were included in the study. All participants in Group G had early to advanced glaucomatous visual field defects but better than 20/20 visual acuity in both eyes. Participants silently read Japanese articles written horizontally while the eye tracking system monitored and calculated reading duration per 100 characters, number of fixations per 100 characters, and mean fixation duration, which were compared with mean deviation and visual field index values from Humphrey visual field testing (24–2 and 10–2 Swedish interactive threshold algorithm standard) of the right versus left eye and the better versus worse eye. Results There was a statistically significant difference between Groups G and N in mean fixation duration (G, 233.4 msec; N, 215.7 msec; P = 0.010). Within Group G, significant correlations were observed between reading duration and 24–2 right mean deviation (rs = -0.280, P = 0.049), 24–2 right visual field index (rs = -0.306, P = 0.030), 24–2 worse visual field index (rs = -0.304, P = 0.032), and 10–2 worse mean deviation (rs = -0.326, P = 0.025). Significant correlations were observed between mean fixation duration and 10–2 left mean deviation (rs = -0.294, P = 0.045) and 10–2 worse mean deviation (rs = -0.306, P = 0.037), respectively. Conclusions The severity of visual field defects may influence some aspects of reading performance. At least concerning silent reading, the visual field of the worse eye is an essential element of smoothness of reading. PMID:28095478
NASA Technical Reports Server (NTRS)
Loisel, Julie; Yu, Zicheng; Beilman, David W.; Camill, Philip; Alm, Jukka; Amesbury, Matthew J.; Anderson, David; Andersson, Sofia; Bochicchio, Christopher; Barber, Keith;
2014-01-01
Here, we present results from the most comprehensive compilation of Holocene peat soil properties with associated carbon and nitrogen accumulation rates for northern peatlands. Our database consists of 268 peat cores from 215 sites located north of 45 deg N. It encompasses regions within which peat carbon data have only recently become available, such as the West Siberia Lowlands, the Hudson Bay Lowlands, Kamchatka in Far East Russia, and the Tibetan Plateau. For all northern peatlands, carbon content in organic matter was estimated at 42 +/- 3% (standard deviation) for Sphagnum peat, 51 +/- 2% for non-Sphagnum peat, and at 49 +/- 2% overall. Dry bulk density averaged 0.12 +/- 0.07 g/cu cm, organic matter bulk density averaged 0.11 +/- 0.05 g/cu cm, and total carbon content in peat averaged 47 +/- 6%. In general, large differences were found between Sphagnum and non-Sphagnum peat types in terms of peat properties. Time-weighted peat carbon accumulation rates averaged 23 +/- 2 (standard error of mean) g C/sq m/yr during the Holocene on the basis of 151 peat cores from 127 sites, with the highest rates of carbon accumulation (25-28 g C/sq m/yr) recorded during the early Holocene when the climate was warmer than the present. Furthermore, we estimate the northern peatland carbon and nitrogen pools at 436 and 10 gigatons, respectively. The database is publicly available at https://peatlands.lehigh.edu.
Air Pollution and Quality of Sperm: A Meta-Analysis
Fathi Najafi, Tahereh; Latifnejad Roudsari, Robab; Namvar, Farideh; Ghavami Ghanbarabadi, Vahid; Hadizadeh Talasaz, Zahra; Esmaeli, Mahin
2015-01-01
Context: Air pollution is common in all countries and affects reproductive functions in men and women. It particularly impacts sperm parameters in men. This meta-analysis aimed to examine the impact of air pollution on the quality of sperm. Evidence Acquisition: The scientific databases of Medline, PubMed, Scopus, Google scholar, Cochrane Library, and Elsevier were searched to identify relevant articles published between 1978 to 2013. In the first step, 76 articles were selected. These studies were ecological correlation, cohort, retrospective, cross-sectional, and case control ones that were found through electronic and hand search of references about air pollution and male infertility. The outcome measurement was the change in sperm parameters. A total of 11 articles were ultimately included in a meta-analysis to examine the impact of air pollution on sperm parameters. The authors applied meta-analysis sheets from Cochrane library, then data extraction, including mean and standard deviation of sperm parameters were calculated and finally their confidence interval (CI) were compared to CI of standard parameters. Results: The CI for pooled means were as follows: 2.68 ± 0.32 for ejaculation volume (mL), 62.1 ± 15.88 for sperm concentration (million per milliliter), 39.4 ± 5.52 for sperm motility (%), 23.91 ± 13.43 for sperm morphology (%) and 49.53 ± 11.08 for sperm count. Conclusions: The results of this meta-analysis showed that air pollution reduces sperm motility, but has no impact on the other sperm parameters of spermogram. PMID:26023349
Stephan, Carl N; Simpson, Ellie K
2008-11-01
With the ever increasing production of average soft tissue depth studies, data are becoming increasingly complex, less standardized, and more unwieldy. So far, no overarching review has been attempted to determine: the validity of continued data collection; the usefulness of the existing data subcategorizations; or if a synthesis is possible to produce a manageable soft tissue depth library. While a principal components analysis would provide the best foundation for such an assessment, this type of investigation is not currently possible because of a lack of easily accessible raw data (first, many studies are narrow; second, raw data are infrequently published and/or stored and are not always shared by some authors). This paper provides an alternate means of investigation using an hierarchical approach to review and compare the effects of single variables on published mean values for adults whilst acknowledging measurement errors and within-group variation. The results revealed: (i) no clear secular trends at frequently investigated landmarks; (ii) wide variation in soft tissue depth measures between different measurement techniques irrespective of whether living persons or cadavers were considered; (iii) no clear clustering of non-Caucasoid data far from the Caucasoid means; and (iv) minor differences between males and females. Consequently, the data were pooled across studies using weighted means and standard deviations to cancel out random and opposing study-specific errors, and to produce a single soft tissue depth table with increased sample sizes (e.g., 6786 individuals at pogonion).
The Regionalization of National-Scale SPARROW Models for Stream Nutrients
Schwarz, G.E.; Alexander, R.B.; Smith, R.A.; Preston, S.D.
2011-01-01
This analysis modifies the parsimonious specification of recently published total nitrogen (TN) and total phosphorus (TP) national-scale SPAtially Referenced Regressions On Watershed attributes models to allow each model coefficient to vary geographically among three major river basins of the conterminous United States. Regionalization of the national models reduces the standard errors in the prediction of TN and TP loads, expressed as a percentage of the predicted load, by about 6 and 7%. We develop and apply a method for combining national-scale and regional-scale information to estimate a hybrid model that imposes cross-region constraints that limit regional variation in model coefficients, effectively reducing the number of free model parameters as compared to a collection of independent regional models. The hybrid TN and TP regional models have improved model fit relative to the respective national models, reducing the standard error in the prediction of loads, expressed as a percentage of load, by about 5 and 4%. Only 19% of the TN hybrid model coefficients and just 2% of the TP hybrid model coefficients show evidence of substantial regional specificity (more than ??100% deviation from the national model estimate). The hybrid models have much greater precision in the estimated coefficients than do the unconstrained regional models, demonstrating the efficacy of pooling information across regions to improve regional models. ?? 2011 American Water Resources Association. This article is a U.S. Government work and is in the public domain in the USA.
Oshio, Takashi; Inoue, Akiomi; Tsutsumi, Akizumi
2018-05-25
We examined the associations among job demands and resources, work engagement, and psychological distress, adjusted for time-invariant individual attributes. We used data from a Japanese occupational cohort survey, which included 18,702 observations of 7,843 individuals. We investigated how work engagement, measured by the Utrecht Work Engagement Scale, was associated with key aspects of job demands and resources, using fixed-effects regression models. We further estimated the fixed-effects models to assess how work engagement moderated the association between each job characteristic and psychological distress as measured by Kessler 6 scores. The fixed-effects models showed that work engagement was positively associated with job resources, as did pooled cross-sectional and prospective cohort models. Specifically, the standardized regression coefficients (β) were 0.148 and 0.120 for extrinsic reward and decision latitude, respectively, compared to -0.159 and 0.020 for role ambiguity and workload and time pressure, respectively (p < 0.001 for all associations). Work engagement modestly moderated the associations of psychological distress with workload and time pressure and extrinsic reward; a one-standard deviation increase in work engagement moderated their associations by 19.2% (p < 0.001) and 11.3% (p = 0.034), respectively. Work engagement was associated with job demands and resources, which is in line with the theoretical prediction of the job demands-resources model, even after controlling for time-invariant individual attributes. Work engagement moderated the association between selected aspects of job demands and resources and psychological distress.
Air pollution and quality of sperm: a meta-analysis.
Fathi Najafi, Tahereh; Latifnejad Roudsari, Robab; Namvar, Farideh; Ghavami Ghanbarabadi, Vahid; Hadizadeh Talasaz, Zahra; Esmaeli, Mahin
2015-04-01
Air pollution is common in all countries and affects reproductive functions in men and women. It particularly impacts sperm parameters in men. This meta-analysis aimed to examine the impact of air pollution on the quality of sperm. The scientific databases of Medline, PubMed, Scopus, Google scholar, Cochrane Library, and Elsevier were searched to identify relevant articles published between 1978 to 2013. In the first step, 76 articles were selected. These studies were ecological correlation, cohort, retrospective, cross-sectional, and case control ones that were found through electronic and hand search of references about air pollution and male infertility. The outcome measurement was the change in sperm parameters. A total of 11 articles were ultimately included in a meta-analysis to examine the impact of air pollution on sperm parameters. The authors applied meta-analysis sheets from Cochrane library, then data extraction, including mean and standard deviation of sperm parameters were calculated and finally their confidence interval (CI) were compared to CI of standard parameters. The CI for pooled means were as follows: 2.68 ± 0.32 for ejaculation volume (mL), 62.1 ± 15.88 for sperm concentration (million per milliliter), 39.4 ± 5.52 for sperm motility (%), 23.91 ± 13.43 for sperm morphology (%) and 49.53 ± 11.08 for sperm count. The results of this meta-analysis showed that air pollution reduces sperm motility, but has no impact on the other sperm parameters of spermogram.
2015-01-01
Atropine, a muscarinic antagonist, is known to inhibit myopia progression in several animal models and humans. However, the mode of action is not established yet. In this study, we compared quantitative iTRAQ proteomic analysis in the retinas collected from control and lens-induced myopic (LIM) mouse eyes treated with atropine. The myopic group received a (−15D) spectacle lens over the right eye on postnatal day 10 with or without atropine eye drops starting on postnatal day 24. Axial length was measured by optical low coherence interferometry (OLCI), AC-Master, and refraction was measured by automated infrared photorefractor at postnatal 24, 38, and 52 days. Retinal tissue samples were pooled from six eyes for each group. The experiments were repeated twice, and technical replicates were also performed for liquid chromatography–tandem mass spectrometry (LC–MS/MS) analysis. MetaCore was used to perform protein profiling for pathway analysis. We identified a total of 3882 unique proteins with <1% FDR by analyzing the samples in replicates for two independent experiments. This is the largest number of mouse retina proteome reported to date. Thirty proteins were found to be up-regulated (ratio for myopia/control > global mean ratio + 1 standard deviation), and 28 proteins were down-regulated (ratio for myopia/control < global mean ratio - 1 standard deviation) in myopic eyes as compared with control retinas. Pathway analysis using MetaCore revealed regulation of γ-aminobutyric acid (GABA) levels in the myopic eyes. Detailed analysis of the quantitative proteomics data showed that the levels of GABA transporter 1 (GAT-1) were elevated in myopic retina and significantly reduced after atropine treatment. These results were further validated with immunohistochemistry and Western blot analysis. In conclusion, this study provides a comprehensive quantitative proteomic analysis of atropine-treated mouse retina and suggests the involvement of GABAergic signaling in the antimyopic effects of atropine in mouse eyes. The GABAergic transmission in the neural retina plays a pivotal role in the maintenance of axial eye growth in mammals. PMID:25211393
Brambilla, Donald J; O'Donnell, Amy B; Matsumoto, Alvin M; McKinlay, John B
2007-12-01
Estimates of intraindividual variation in hormone levels provide the basis for interpreting hormone measurements clinically and for developing eligibility criteria for trials of hormone replacement therapy. However, reliable systematic estimates of such variation are lacking. To estimate intraindividual variation of serum total, free and bioavailable testosterone (T), dihydrotestosterone (DHT), SHBG, LH, dehydroepiandrosterone (DHEA), dehydroepiandrosterone sulphate (DHEAS), oestrone, oestradiol and cortisol, and the contributions of biological and assay variation to the total. Paired blood samples were obtained 1-3 days apart at entry and again 3 months and 6 months later (maximum six samples per subject). Each sample consisted of a pool of equal aliquots of two blood draws 20 min apart. Men aged 30-79 years were randomly selected from the respondents to the Boston Area Community Health Survey, a study of the health of the general population of Boston, MA, USA. Analysis was based on 132 men, including 121 who completed all six visits, 8 who completed the first two visits and 3 who completed the first four visits. Day-to-day and 3-month (long-term) intraindividual standard deviations, after transforming measurements to logarithms to eliminate the contribution of hormone level to intraindividual variation. Biological variation generally accounted for more of total intraindividual variation than did assay variation. Day-to-day biological variation accounted for more of the total than did long-term biological variation. Short-term variability was greater in hormones with pulsatile secretion (e.g. LH) than those that exhibit less ultradian variation. Depending on the hormone, the intraindividual standard deviations imply that a clinician can expect to see a difference exceeding 18-28% about half the time when two measurements are made on a subject. The difference will exceed 27-54% about a quarter of the time. Given the level of intraindividual variability in hormone levels found in this study, one sample is generally not sufficient to characterize an individual's hormone levels but collecting more than three is probably not warranted. This is true for clinical measurements and for hormone measurements used to determine eligibility for a clinical trial of hormone replacement therapy.
Shungin, Dmitry; Cornelis, Marilyn C; Divaris, Kimon; Holtfreter, Birte; Shaffer, John R; Yu, Yau-Hua; Barros, Silvana P; Beck, James D; Biffar, Reiner; Boerwinkle, Eric A; Crout, Richard J.; Ganna, Andrea; Hallmans, Goran; Hindy, George; Hu, Frank B; Kraft, Peter; McNeil, Daniel W; Melander, Olle; Moss, Kevin L; North, Kari E; Orho-Melander, Marju; Pedersen, Nancy L; Ridker, Paul M; Rimm, Eric B; Rose, Lynda M; Rukh, Gull; Teumer, Alexander; Weyant, Robert J; Chasman, Daniel I; Joshipura, Kaumudi; Kocher, Thomas; Magnusson, Patrik KE; Marazita, Mary L; Nilsson, Peter; Offenbacher, Steve; Davey Smith, George; Lundberg, Pernilla; Palmer, Tom M; Timpson, Nicholas J; Johansson, Ingegerd; Franks, Paul W
2015-01-01
Background: The observational relationship between obesity and periodontitis is widely known, yet causal evidence is lacking. Our objective was to investigate causal associations between periodontitis and body mass index (BMI). Methods: We performed Mendelian randomization analyses with BMI-associated loci combined in a genetic risk score (GRS) as the instrument for BMI. All analyses were conducted within the Gene-Lifestyle Interactions and Dental Endpoints (GLIDE) Consortium in 13 studies from Europe and the USA, including 49 066 participants with clinically assessed (seven studies, 42.1% of participants) and self-reported (six studies, 57.9% of participants) periodontitis and genotype data (17 672/31 394 with/without periodontitis); 68 761 participants with BMI and genotype data; and 57 871 participants (18 881/38 990 with/without periodontitis) with data on BMI and periodontitis. Results: In the observational meta-analysis of all participants, the pooled crude observational odds ratio (OR) for periodontitis was 1.13 [95% confidence interval (CI): 1.03, 1.24] per standard deviation increase of BMI. Controlling for potential confounders attenuated this estimate (OR = 1.08; 95% CI:1.03, 1.12). For clinically assessed periodontitis, corresponding ORs were 1.25 (95% CI: 1.10, 1.42) and 1.13 (95% CI: 1.10, 1.17), respectively. In the genetic association meta-analysis, the OR for periodontitis was 1.01 (95% CI: 0.99, 1.03) per GRS unit (per one effect allele) in all participants and 1.00 (95% CI: 0.97, 1.03) in participants with clinically assessed periodontitis. The instrumental variable meta-analysis of all participants yielded an OR of 1.05 (95% CI: 0.80, 1.38) per BMI standard deviation, and 0.90 (95% CI: 0.56, 1.46) in participants with clinical data. Conclusions: Our study does not support total adiposity as a causal risk factor for periodontitis, as the point estimate is very close to the null in the causal inference analysis, with wide confidence intervals. PMID:26050256
Patel, Shivani A; Ali, Mohammed K; Alam, Dewan; Yan, Lijing L; Levitt, Naomi S; Bernabe-Ortiz, Antonio; Checkley, William; Wu, Yangfeng; Irazola, Vilma; Gutierrez, Laura; Rubinstein, Adolfo; Shivashankar, Roopa; Li, Xian; Miranda, J Jaime; Chowdhury, Muhammad Ashique Haider; Siddiquee, Ali Tanweer; Gaziano, Thomas A; Kadir, M Masood; Prabhakaran, Dorairaj
2016-03-01
The implications of rising obesity for cardiovascular health in middle-income countries has generated interest, in part because associations between obesity and cardiovascular health seem to vary across ethnic groups. We assessed general and central obesity in Africa, East Asia, South America, and South Asia. We further investigated whether body mass index (BMI) and waist circumference differentially relate to cardiovascular health; and associations between obesity metrics and adverse cardiovascular health vary by region. Using baseline anthropometric data collected between 2008 and 2012 from 7 cohorts in 9 countries, we estimated the proportion of participants with general and central obesity using BMI and waist circumference classifications, respectively, by study site. We used Poisson regression to examine the associations (prevalence ratios) of continuously measured BMI and waist circumference with prevalent diabetes and hypertension by sex. Pooled estimates across studies were computed by sex and age. This study analyzed data from 31,118 participants aged 20 to 79 years. General obesity was highest in South Asian cities and central obesity was highest in South America. The proportion classified with general obesity (range 11% to 50%) tended to be lower than the proportion classified as centrally obese (range 19% to 79%). Every standard deviation higher of BMI was associated with 1.65 and 1.60 times higher probability of diabetes and 1.42 and 1.28 times higher probability of hypertension, for men and women, respectively, aged 40 to 69 years. Every standard deviation higher of waist circumference was associated with 1.48 and 1.74 times higher probability of diabetes and 1.34 and 1.31 times higher probability of hypertension, for men and women, respectively, aged 40 to 69 years. Associations of obesity measures with diabetes were strongest in South Africa among men and in South America among women. Associations with hypertension were weakest in South Africa among both sexes. BMI and waist circumference were both reasonable predictors of prevalent diabetes and hypertension. Across diverse ethnicities and settings, BMI and waist circumference remain salient metrics of obesity that can identify those with increased cardiovascular risk. Copyright © 2016 World Heart Federation (Geneva). Published by Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shibata, K.; Ogata, T.; Nyilas, A.
2006-03-31
Ogata et al. reported in 1996 results of international Round Robin tests on mechanical property measurement of several metals at cryogenic temperatures. Following the report, the standard deviation of Young's modulus of 316L steel is much larger than those of yield and tensile strengths, that is, 4.6 % of the mean value for Young's modulus, while 1.4 % and 1.6 % of the mean values for yield and for tensile strengths, respectively. Therefore, an international Round Robin test on Young's modulus of two austenitic stainless steels at cryogenic temperatures under the participation often institutes from four nations has been initiatedmore » within these two years. As a result, the ratios of standard deviation to the mean values are 4.2 % for 304L and 3.6 % for 316L. Such a drop in the standard deviation is attributable to the decrease in the number of institute owing to the application of single extensometer or direct strain gage technique.« less
Liu, Gordon G; Xue, Xindong; Yu, Chenxi; Wang, Yafeng
2016-09-01
This paper uses longitudinal data from China to examine the causal relationship between structural social capital and health among Chinese older adults. We employ various econometric strategies to control for the potential endogeneity of social capital and account for the possible contextual confounding effects by including community-level social capital. We use three indicators to measure individuals' general, physical, and mental health. Results indicate that social capital has a significant and positive effect on general and physical health. Based on our primary IV findings, a one standard-deviation increase in social capital leads to a 4.9 standard-deviation decrease in the probability of having bad health and a 2.2 standard-deviation decrease in physical activity limitations. Our results are robust to a series of sensitivity checks. Further analysis suggests heterogeneous effects by age but not by gender or area of residence. Copyright © 2016 Elsevier B.V. All rights reserved.
Koenig, Bruce E; Lacey, Douglas S
2014-07-01
In this research project, nine small digital audio recorders were tested using five sets of 30-min recordings at all available recording modes, with consistent audio material, identical source and microphone locations, and identical acoustic environments. The averaged direct current (DC) offset values and standard deviations were measured for 30-sec and 1-, 2-, 3-, 6-, 10-, 15-, and 30-min segments. The research found an inverse association between segment lengths and the standard deviation values and that lengths beyond 30 min may not meaningfully reduce the standard deviation values. This research supports previous studies indicating that measured averaged DC offsets should only be used for exclusionary purposes in authenticity analyses and exhibit consistent values when the general acoustic environment and microphone/recorder configurations were held constant. Measured average DC offset values from exemplar recorders may not be directly comparable to those of submitted digital audio recordings without exactly duplicating the acoustic environment and microphone/recorder configurations. © 2014 American Academy of Forensic Sciences.
Historical Precision of an Ozone Correction Procedure for AM0 Solar Cell Calibration
NASA Technical Reports Server (NTRS)
Snyder, David B.; Jenkins, Phillip; Scheiman, David
2005-01-01
In an effort to improve the accuracy of the high altitude aircraft method for calibration of high band-gap solar cells, the ozone correction procedure has been revisited. The new procedure adjusts the measured short circuit current, Isc, according to satellite based ozone measurements and a model of the atmospheric ozone profile then extrapolates the measurements to air mass zero, AMO. The purpose of this paper is to assess the precision of the revised procedure by applying it to historical data sets. The average Isc of a silicon cell for a flying season increased 0.5% and the standard deviation improved from 0.5% to 0.3%. The 12 year average Isc of a GaAs cell increased 1% and the standard deviation improved from 0.8% to 0.5%. The slight increase in measured Isc and improvement in standard deviation suggests that the accuracy of the aircraft method may improve from 1% to nearly 0.5%.
Active laser ranging with frequency transfer using frequency comb
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Hongyuan; Wei, Haoyun; Yang, Honglei
2016-05-02
A comb-based active laser ranging scheme is proposed for enhanced distance resolution and a common time standard for the entire system. Three frequency combs with different repetition rates are used as light sources at the two ends where the distance is measured. Pulse positions are determined through asynchronous optical sampling and type II second harmonic generation. Results show that the system achieves a maximum residual of 379.6 nm and a standard deviation of 92.9 nm with 2000 averages over 23.6 m. Moreover, as for the frequency transfer, an atom clock and an adjustable signal generator, synchronized to the atom clock, are used asmore » time standards for the two ends to appraise the frequency deviation introduced by the proposed system. The system achieves a residual fractional deviation of 1.3 × 10{sup −16} for 1 s, allowing precise frequency transfer between the two clocks at the two ends.« less
Signal averaging limitations in heterodyne- and direct-detection laser remote sensing measurements
NASA Technical Reports Server (NTRS)
Menyuk, N.; Killinger, D. K.; Menyuk, C. R.
1983-01-01
The improvement in measurement uncertainty brought about by the averaging of increasing numbers of pulse return signals in both heterodyne- and direct-detection lidar systems is investigated. A theoretical analysis is presented which shows the standard deviation of the mean measurement to decrease as the inverse square root of the number of measurements, except in the presence of temporal correlation. Experimental measurements based on a dual-hybrid-TEA CO2 laser differential absorption lidar system are reported which demonstrate that the actual reduction in the standard deviation of the mean in both heterodyne- and direct-detection systems is much slower than the inverse square-root dependence predicted for uncorrelated signals, but is in agreement with predictions in the event of temporal correlation. Results thus favor the use of direct detection at relatively short range where the lower limit of the standard deviation of the mean is about 2 percent, but advantages of heterodyne detection at longer ranges are noted.
Age-independent anti-Müllerian hormone (AMH) standard deviation scores to estimate ovarian function.
Helden, Josef van; Weiskirchen, Ralf
2017-06-01
To determine single year age-specific anti-Müllerian hormone (AMH) standard deviation scores (SDS) for women associated to normal ovarian function and different ovarian disorders resulting in sub- or infertility. Determination of particular year median and mean AMH values with standard deviations (SD), calculation of age-independent cut off SDS for the discrimination between normal ovarian function and ovarian disorders. Single-year-specific median, mean, and SD values have been evaluated for the Beckman Access AMH immunoassay. While the decrease of both median and mean AMH values is strongly correlated with increasing age, calculated SDS values have been shown to be age independent with the differentiation between normal ovarian function measured as occurred ovulation with sufficient luteal activity compared with hyperandrogenemic cycle disorders or anovulation associated with high AMH values and reduced ovarian activity or insufficiency associated with low AMH, respectively. These results will be helpful for the treatment of patients and the ventilation of the different reproductive options. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Smith, Wayne Farrior
1973-01-01
The effect of finite source size on the power statistics in a reverberant room for pure tone excitation was investigated. Theoretical results indicate that the standard deviation of low frequency, pure tone finite sources is always less than that predicted by point source theory and considerably less when the source dimension approaches one-half an acoustic wavelength or greater. A supporting experimental study was conducted utilizing an eight inch loudspeaker and a 30 inch loudspeaker at eleven source positions. The resulting standard deviation of sound power output of the smaller speaker is in excellent agreement with both the derived finite source theory and existing point source theory, if the theoretical data is adjusted to account for experimental incomplete spatial averaging. However, the standard deviation of sound power output of the larger speaker is measurably lower than point source theory indicates, but is in good agreement with the finite source theory.
NASA Technical Reports Server (NTRS)
Chadwick, C.
1984-01-01
This paper describes the development and use of an algorithm to compute approximate statistics of the magnitude of a single random trajectory correction maneuver (TCM) Delta v vector. The TCM Delta v vector is modeled as a three component Cartesian vector each of whose components is a random variable having a normal (Gaussian) distribution with zero mean and possibly unequal standard deviations. The algorithm uses these standard deviations as input to produce approximations to (1) the mean and standard deviation of the magnitude of Delta v, (2) points of the probability density function of the magnitude of Delta v, and (3) points of the cumulative and inverse cumulative distribution functions of Delta v. The approximates are based on Monte Carlo techniques developed in a previous paper by the author and extended here. The algorithm described is expected to be useful in both pre-flight planning and in-flight analysis of maneuver propellant requirements for space missions.
A Priori Subgrid Scale Modeling for a Droplet Laden Temporal Mixing Layer
NASA Technical Reports Server (NTRS)
Okongo, Nora; Bellan, Josette
2000-01-01
Subgrid analysis of a transitional temporal mixing layer with evaporating droplets has been performed using a direct numerical simulation (DNS) database. The DNS is for a Reynolds number (based on initial vorticity thickness) of 600, with droplet mass loading of 0.2. The gas phase is computed using a Eulerian formulation, with Lagrangian droplet tracking. Since Large Eddy Simulation (LES) of this flow requires the computation of unfiltered gas-phase variables at droplet locations from filtered gas-phase variables at the grid points, it is proposed to model these by assuming the gas-phase variables to be given by the filtered variables plus a correction based on the filtered standard deviation, which can be computed from the sub-grid scale (SGS) standard deviation. This model predicts unfiltered variables at droplet locations better than simply interpolating the filtered variables. Three methods are investigated for modeling the SGS standard deviation: Smagorinsky, gradient and scale-similarity. When properly calibrated, the gradient and scale-similarity methods give results in excellent agreement with the DNS.
Brown, Gary S.; Betty, Rita G.; Brockmann, John E.; Lucero, Daniel A.; Souza, Caroline A.; Walsh, Kathryn S.; Boucher, Raymond M.; Tezak, Mathew; Wilson, Mollye C.; Rudolph, Todd
2007-01-01
Polyester-rayon blend wipes were evaluated for efficiency of extraction and recovery of powdered Bacillus atrophaeus spores from stainless steel and painted wallboard surfaces. Method limits of detection were also estimated for both surfaces. The observed mean efficiency of polyester-rayon blend wipe recovery from stainless steel was 0.35 with a standard deviation of ±0.12, and for painted wallboard it was 0.29 with a standard deviation of ±0.15. Evaluation of a sonication extraction method for the polyester-rayon blend wipes produced a mean extraction efficiency of 0.93 with a standard deviation of ±0.09. Wipe recovery quantitative limits of detection were estimated at 90 CFU per unit of stainless steel sample area and 105 CFU per unit of painted wallboard sample area. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling following the release of a biological agent such as Bacillus anthracis. PMID:17122390
Brown, Gary S; Betty, Rita G; Brockmann, John E; Lucero, Daniel A; Souza, Caroline A; Walsh, Kathryn S; Boucher, Raymond M; Tezak, Mathew; Wilson, Mollye C; Rudolph, Todd
2007-02-01
Polyester-rayon blend wipes were evaluated for efficiency of extraction and recovery of powdered Bacillus atrophaeus spores from stainless steel and painted wallboard surfaces. Method limits of detection were also estimated for both surfaces. The observed mean efficiency of polyester-rayon blend wipe recovery from stainless steel was 0.35 with a standard deviation of +/-0.12, and for painted wallboard it was 0.29 with a standard deviation of +/-0.15. Evaluation of a sonication extraction method for the polyester-rayon blend wipes produced a mean extraction efficiency of 0.93 with a standard deviation of +/-0.09. Wipe recovery quantitative limits of detection were estimated at 90 CFU per unit of stainless steel sample area and 105 CFU per unit of painted wallboard sample area. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling following the release of a biological agent such as Bacillus anthracis.
McLain, B.J.
1993-01-01
Graphite furnace atomic absorption spectrophotometry is a sensitive, precise, and accurate method for the determination of chromium in natural water samples. The detection limit for this analytical method is 0.4 microg/L with a working linear limit of 25.0 microg/L. The precision at the detection limit ranges from 20 to 57 percent relative standard deviation (RSD) with an improvement to 4.6 percent RSD for concentrations more than 3 microg/L. Accuracy of this method was determined for a variety of reference standards that was representative of the analytical range. The results were within the established standard deviations. Samples were spiked with known concentrations of chromium with recoveries ranging from 84 to 122 percent. In addition, a comparison of data between graphite furnace atomic absorption spectrophotometry and direct-current plasma atomic emission spectrometry resulted in suitable agreement between the two methods, with an average deviation of +/- 2.0 microg/L throughout the analytical range.
Exploring local regularities for 3D object recognition
NASA Astrophysics Data System (ADS)
Tian, Huaiwen; Qin, Shengfeng
2016-11-01
In order to find better simplicity measurements for 3D object recognition, a new set of local regularities is developed and tested in a stepwise 3D reconstruction method, including localized minimizing standard deviation of angles(L-MSDA), localized minimizing standard deviation of segment magnitudes(L-MSDSM), localized minimum standard deviation of areas of child faces (L-MSDAF), localized minimum sum of segment magnitudes of common edges (L-MSSM), and localized minimum sum of areas of child face (L-MSAF). Based on their effectiveness measurements in terms of form and size distortions, it is found that when two local regularities: L-MSDA and L-MSDSM are combined together, they can produce better performance. In addition, the best weightings for them to work together are identified as 10% for L-MSDSM and 90% for L-MSDA. The test results show that the combined usage of L-MSDA and L-MSDSM with identified weightings has a potential to be applied in other optimization based 3D recognition methods to improve their efficacy and robustness.
POOL WATER TREATMENT AND COOLING SYSTEM DESCRIPTION DOCUMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
V. King
2000-06-19
The Pool Water Treatment and Cooling System is located in the Waste Handling Building (WHB), and is comprised of various process subsystems designed to support waste handling operations. This system maintains the pool water temperature within an acceptable range, maintains water quality standards that support remote underwater operations and prevent corrosion, detects leakage from the pool liner, provides the capability to remove debris from the pool, controls the pool water level, and helps limit radiological exposure to personnel. The pool structure and liner, pool lighting, and the fuel staging racks in the pool are not within the scope of themore » Pool Water Treatment and Cooling System. Pool water temperature control is accomplished by circulating the pool water through heat exchangers. Adequate circulation and mixing of the pool water is provided to prevent localized thermal hotspots in the pool. Treatment of the pool water is accomplished by a water treatment system that circulates the pool water through filters, and ion exchange units. These water treatment units remove radioactive and non-radioactive particulate and dissolved solids from the water, thereby providing the water clarity needed to conduct waste handling operations. The system also controls pool water chemistry to prevent advanced corrosion of the pool liner, pool components, and fuel assemblies. Removal of radioactivity from the pool water contributes to the project ALARA (as low as is reasonably achievable) goals. A leak detection system is provided to detect and alarm leaks through the pool liner. The pool level control system monitors the water level to ensure that the minimum water level required for adequate radiological shielding is maintained. Through interface with a demineralized water system, adequate makeup is provided to compensate for loss of water inventory through evaporation and waste handling operations. Interface with the Site Radiological Monitoring System provides continuous radiological monitoring of the pool water. The Pool Water Treatment and Cooling System interfaces with the Waste Handling Building System, Site-Generated Radiological Waste Handling System, Site Radiological Monitoring System, Waste Handling Building Electrical System, Site Water System, and the Monitored Geologic Repository Operations Monitoring and Control System.« less
Impact of operator on determining functional parameters of nuclear medicine procedures.
Mohammed, A M; Naddaf, S Y; Mahdi, F S; Al-Mutawa, Q I; Al-Dossary, H A; Elgazzar, A H
2006-01-01
The study was designed to assess the significance of the interoperator variability in the estimation of functional parameters for four nuclear medicine procedures. Three nuclear medicine technologists with varying years of experience processed the following randomly selected 20 cases with diverse functions of each study type: renography, renal cortical scans, myocardial perfusion gated single-photon emission computed tomography (MP-GSPECT) and gated blood pool ventriculography (GBPV). The technologists used the same standard processing routines and were blinded to the results of each other. The means of the values and the means of differences calculated case by case were statistically analyzed by one-way ANOVA. The values were further analyzed using Pearson correlation. The range of the mean values and standard deviation of relative renal function obtained by the three technologists were 50.65 +/- 3.9 to 50.92 +/- 4.4% for renography, 51.43 +/- 8.4 to 51.55 +/- 8.8% for renal cortical scans, 57.40 +/- 14.3 to 58.30 +/- 14.9% for left ventricular ejection fraction from MP-GSPECT and 54.80 +/- 12.8 to 55.10 +/- 13.1% for GBPV. The difference was not statistically significant, p > 0.9. The values showed a high correlation of more than 0.95. Calculated case by case, the mean of differences +/- SD was found to range from 0.42 +/- 0.36% in renal cortical scans to 1.35 +/- 0.87% in MP-GSPECT with a maximum difference of 4.00%. The difference was not statistically significant, p > 0.19. The estimated functional parameters were reproducible and operator independent as long as the standard processing instructions were followed. Copyright 2006 S. Karger AG, Basel.
Assessment of MODIS-derived indices (2001-2013) to drought across Taiwan's forests
NASA Astrophysics Data System (ADS)
Chang, Chung-Te; Wang, Hsueh-Ching; Huang, Cho-ying
2018-05-01
Tropical and subtropical ecosystems, the largest terrestrial carbon pools, are very susceptible to the variability of seasonal precipitation. However, the assessment of drought conditions in these regions is often overlooked due to the preconceived notion of the presence of high humidity. Drought indices derived from remotely sensed imagery have been commonly used for large-scale monitoring, but feasibility of drought assessment may vary across regions due to climate regimes and local biophysical conditions. Therefore, this study aims to evaluate the feasibility of 11 commonly used MODIS-derived vegetation/drought index in the forest regions of Taiwan through comparison with the station-based standardized precipitation index with a 3-month time scale (SPI3). The drought indices were further transformed (standardized anomaly, SA) to make them better delineate the spatiotemporal variations of drought conditions. The results showed that the Normalized Difference Infrared Index utilizing the near-infrared and shortwave infrared bands (NDII6) may be more superior to other indices in delineating drought patterns. Overall, the NDII6 SA-SPI3 pair yielded the highest correlation (mean r ± standard deviation = 0.31 ± 0.13) and was most significant in central and south Taiwan ( r = 0.50-0.90) during the cold, dry season (January and April). This study illustrated that the NDII6 is suitable to delineate drought conditions in a relatively humid region. The results suggested the better performance of the NDII6 SA-SPI3 across the high climate gradient, especially in the regions with dramatic interannual amplifications of rainfall. This synthesis was conducted across a wide bioclimatic gradient, and the findings could be further generalized to a much broader geographical extent.
Robust Identification of Local Adaptation from Allele Frequencies
Günther, Torsten; Coop, Graham
2013-01-01
Comparing allele frequencies among populations that differ in environment has long been a tool for detecting loci involved in local adaptation. However, such analyses are complicated by an imperfect knowledge of population allele frequencies and neutral correlations of allele frequencies among populations due to shared population history and gene flow. Here we develop a set of methods to robustly test for unusual allele frequency patterns and correlations between environmental variables and allele frequencies while accounting for these complications based on a Bayesian model previously implemented in the software Bayenv. Using this model, we calculate a set of “standardized allele frequencies” that allows investigators to apply tests of their choice to multiple populations while accounting for sampling and covariance due to population history. We illustrate this first by showing that these standardized frequencies can be used to detect nonparametric correlations with environmental variables; these correlations are also less prone to spurious results due to outlier populations. We then demonstrate how these standardized allele frequencies can be used to construct a test to detect SNPs that deviate strongly from neutral population structure. This test is conceptually related to FST and is shown to be more powerful, as we account for population history. We also extend the model to next-generation sequencing of population pools—a cost-efficient way to estimate population allele frequencies, but one that introduces an additional level of sampling noise. The utility of these methods is demonstrated in simulations and by reanalyzing human SNP data from the Human Genome Diversity Panel populations and pooled next-generation sequencing data from Atlantic herring. An implementation of our method is available from http://gcbias.org. PMID:23821598
NASA Astrophysics Data System (ADS)
Prentice, Boone M.; Chumbley, Chad W.; Caprioli, Richard M.
2017-01-01
Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) allows for the visualization of molecular distributions within tissue sections. While providing excellent molecular specificity and spatial information, absolute quantification by MALDI IMS remains challenging. Especially in the low molecular weight region of the spectrum, analysis is complicated by matrix interferences and ionization suppression. Though tandem mass spectrometry (MS/MS) can be used to ensure chemical specificity and improve sensitivity by eliminating chemical noise, typical MALDI MS/MS modalities only scan for a single MS/MS event per laser shot. Herein, we describe TOF/TOF instrumentation that enables multiple fragmentation events to be performed in a single laser shot, allowing the intensity of the analyte to be referenced to the intensity of the internal standard in each laser shot while maintaining the benefits of MS/MS. This approach is illustrated by the quantitative analyses of rifampicin (RIF), an antibiotic used to treat tuberculosis, in pooled human plasma using rifapentine (RPT) as an internal standard. The results show greater than 4-fold improvements in relative standard deviation as well as improved coefficients of determination (R2) and accuracy (>93% quality controls, <9% relative errors). This technology is used as an imaging modality to measure absolute RIF concentrations in liver tissue from an animal dosed in vivo. Each microspot in the quantitative image measures the local RIF concentration in the tissue section, providing absolute pixel-to-pixel quantification from different tissue microenvironments. The average concentration determined by IMS is in agreement with the concentration determined by HPLC-MS/MS, showing a percent difference of 10.6%.
Assessment of MODIS-derived indices (2001-2013) to drought across Taiwan's forests
NASA Astrophysics Data System (ADS)
Chang, Chung-Te; Wang, Hsueh-Ching; Huang, Cho-ying
2017-12-01
Tropical and subtropical ecosystems, the largest terrestrial carbon pools, are very susceptible to the variability of seasonal precipitation. However, the assessment of drought conditions in these regions is often overlooked due to the preconceived notion of the presence of high humidity. Drought indices derived from remotely sensed imagery have been commonly used for large-scale monitoring, but feasibility of drought assessment may vary across regions due to climate regimes and local biophysical conditions. Therefore, this study aims to evaluate the feasibility of 11 commonly used MODIS-derived vegetation/drought index in the forest regions of Taiwan through comparison with the station-based standardized precipitation index with a 3-month time scale (SPI3). The drought indices were further transformed (standardized anomaly, SA) to make them better delineate the spatiotemporal variations of drought conditions. The results showed that the Normalized Difference Infrared Index utilizing the near-infrared and shortwave infrared bands (NDII6) may be more superior to other indices in delineating drought patterns. Overall, the NDII6 SA-SPI3 pair yielded the highest correlation (mean r ± standard deviation = 0.31 ± 0.13) and was most significant in central and south Taiwan (r = 0.50-0.90) during the cold, dry season (January and April). This study illustrated that the NDII6 is suitable to delineate drought conditions in a relatively humid region. The results suggested the better performance of the NDII6 SA-SPI3 across the high climate gradient, especially in the regions with dramatic interannual amplifications of rainfall. This synthesis was conducted across a wide bioclimatic gradient, and the findings could be further generalized to a much broader geographical extent.
Improved Bond Strength of Cyanoacrylate Adhesives Through Nanostructured Chromium Adhesion Layers
NASA Astrophysics Data System (ADS)
Gobble, Kyle; Stark, Amelia; Stagon, Stephen P.
2016-09-01
The performance of many consumer products suffers due to weak and inconsistent bonds formed to low surface energy polymer materials, such as polyolefin-based high-density polyethylene (HDPE), with adhesives, such as cyanoacrylate. In this letter, we present an industrially relevant means of increasing bond shear strength and consistency through vacuum metallization of chromium thin films and nanorods, using HDPE as a prototype material and cyanoacrylate as a prototype adhesive. For the as received HDPE surfaces, unmodified bond shear strength is shown to be only 0.20 MPa with a standard deviation of 14 %. When Cr metallization layers are added onto the HDPE at thicknesses of 50 nm or less, nanorod-structured coatings outperform continuous films and have a maximum bond shear strength of 0.96 MPa with a standard deviation of 7 %. When the metallization layer is greater than 50 nm thick, continuous films demonstrate greater performance than nanorod coatings and have a maximum shear strength of 1.03 MPa with a standard deviation of 6 %. Further, when the combination of surface roughening with P400 grit sandpaper and metallization is used, 100-nm-thick nanorod coatings show a tenfold increase in shear strength over the baseline, reaching a maximum of 2.03 MPa with a standard deviation of only 3 %. The substantial increase in shear strength through metallization, and the combination of roughening with metallization, may have wide-reaching implications in consumer products which utilize low surface energy plastics.
Zhao, Pengxiang; Zhou, Suhong
2018-01-01
Traditionally, static units of analysis such as administrative units are used when studying obesity. However, using these fixed contextual units ignores environmental influences experienced by individuals in areas beyond their residential neighborhood and may render the results unreliable. This problem has been articulated as the uncertain geographic context problem (UGCoP). This study investigates the UGCoP through exploring the relationships between the built environment and obesity based on individuals’ activity space. First, a survey was conducted to collect individuals’ daily activity and weight information in Guangzhou in January 2016. Then, the data were used to calculate and compare the values of several built environment variables based on seven activity space delineations, including home buffers, workplace buffers (WPB), fitness place buffers (FPB), the standard deviational ellipse at two standard deviations (SDE2), the weighted standard deviational ellipse at two standard deviations (WSDE2), the minimum convex polygon (MCP), and road network buffers (RNB). Lastly, we conducted comparative analysis and regression analysis based on different activity space measures. The results indicate that significant differences exist between variables obtained with different activity space delineations. Further, regression analyses show that the activity space delineations used in the analysis have a significant influence on the results concerning the relationships between the built environment and obesity. The study sheds light on the UGCoP in analyzing the relationships between obesity and the built environment. PMID:29439392
Role of a Standardized Prism Under Cover Test in the Assessment of Dissociated Vertical Deviation.
Klaehn, Lindsay D; Hatt, Sarah R; Leske, David A; Holmes, Jonathan M
2018-03-01
Dissociated vertical deviation (DVD) is commonly measured using a prism and alternate cover test (PACT), but some providers use a prism under cover test (PUCT). The aim of this study was to compare a standardized PUCT measurement with a PACT measurement, for assessing the magnitude of DVD. Thirty-six patients with a clinical diagnosis of DVD underwent measurement of the angle of deviation with the PACT, fixing with the habitually fixing eye, and with PUCT, fixing both right and left eyes. The PUCT was standardized, using a 10-second cover for each prism magnitude, until the deviation was neutralized. The magnitude of hyperdeviation by PACT and PUCT was compared for the non-fixing eye, using paired non-parametric tests. The frequency of discrepancies more than 4 prism diopters (PD) between PACT and PUCT was calculated. The magnitude of hyperdeviation was greater when measured with PUCT (range 8PD hypodeviation to 20PD hyperdeviation) vs. PACT (18PD hypodeviation to 25PD hyperdeviation) with a median difference of 4.5PD (range -5PD to 21PD); P < 0.0001. Eighteen (50%) of 36 measurements elicited >4PD hyperdeviation (or >4PD less hypodeviation) by PUCT than by PACT. A standardized 10-second PUCT yields greater values than a prism and alternate cover test in the majority of patients with DVD, providing better quantification of the severity of DVD, which may be important for management decisions.
An intelligent switch with back-propagation neural network based hybrid power system
NASA Astrophysics Data System (ADS)
Perdana, R. H. Y.; Fibriana, F.
2018-03-01
The consumption of conventional energy such as fossil fuels plays the critical role in the global warming issues. The carbon dioxide, methane, nitrous oxide, etc. could lead the greenhouse effects and change the climate pattern. In fact, 77% of the electrical energy is generated from fossil fuels combustion. Therefore, it is necessary to use the renewable energy sources for reducing the conventional energy consumption regarding electricity generation. This paper presents an intelligent switch to combine both energy resources, i.e., the solar panels as the renewable energy with the conventional energy from the State Electricity Enterprise (PLN). The artificial intelligence technology with the back-propagation neural network was designed to control the flow of energy that is distributed dynamically based on renewable energy generation. By the continuous monitoring on each load and source, the dynamic pattern of the intelligent switch was better than the conventional switching method. The first experimental results for 60 W solar panels showed the standard deviation of the trial at 0.7 and standard deviation of the experiment at 0.28. The second operation for a 900 W of solar panel obtained the standard deviation of the trial at 0.05 and 0.18 for the standard deviation of the experiment. Moreover, the accuracy reached 83% using this method. By the combination of the back-propagation neural network with the observation of energy usage of the load using wireless sensor network, each load can be evenly distributed and will impact on the reduction of conventional energy usage.
The UNITAID Patent Pool Initiative: Bringing Patents Together for the Common Good.
Bermudez, Jorge; 't Hoen, Ellen
2010-01-19
Developing and delivering appropriate, affordable, well-adapted medicines for HIV/AIDS remains an urgent challenge: as first-line therapies fail, increasing numbers of people require costly second-line therapy; one-third of ARVs are not available in pediatric formulations; and certain key first- and second-line triple fixed-dose combinations do not exist or sufficient suppliers are lacking. UNITAID aims to help solve these problems through an innovative initiative for the collective management of intellectual property (IP) rights - a patent pool for HIV medicines. The idea behind a patent pool is that patent holders - companies, governments, researchers or universities - voluntarily offer, under certain conditions, the IP related to their inventions to the patent pool. Any company that wants to use the IP to produce or develop medicines can seek a license from the pool against the payment of royalties, and may then produce the medicines for use in developing countries (conditional upon meeting agreed quality standards). The patent pool will be a voluntary mechanism, meaning its success will largely depend on the willingness of pharmaceutical companies to participate and commit their IP to the pool. Generic producers must also be willing to cooperate. The pool has the potential to provide benefits to all.
40 CFR 792.81 - Standard operating procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 33 2013-07-01 2013-07-01 false Standard operating procedures. 792.81... operating procedures. (a) A testing facility shall have standard operating procedures in writing, setting... data generated in the course of a study. All deviations in a study from standard operating procedures...
40 CFR 792.81 - Standard operating procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 33 2012-07-01 2012-07-01 false Standard operating procedures. 792.81... operating procedures. (a) A testing facility shall have standard operating procedures in writing, setting... data generated in the course of a study. All deviations in a study from standard operating procedures...
40 CFR 792.81 - Standard operating procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 32 2014-07-01 2014-07-01 false Standard operating procedures. 792.81... operating procedures. (a) A testing facility shall have standard operating procedures in writing, setting... data generated in the course of a study. All deviations in a study from standard operating procedures...
Heil, Andreas; Ohsam, Jürgen; van Genugten, Bernard; Diez, Oscar; Yokoyama, Keiichi; Kumazawa, Yoshiyuki; Pasternack, Ralf; Hils, Martin
2017-08-16
The effect of standard bakery concentrations of microbial transglutaminase (MTG) in wheat bread preparation on the immunoreactivity of sera of celiac disease (CD) patients was investigated. Immunoblotting using monoclonal antibodies specific to unmodified and/or deamidated gliadin showed no differences between control bread and MTG bread. Deamidation of gliadin could not be detected at standard MTG concentrations. Sera of CD patients were characterized using anti-gliadin and anti-deamidated gliadin peptide (DGP) enzyme-linked immunosorbent assay and grouped into DGP high- and low-titer pools. The recognition pattern obtained after using both CD sera pools for immunoblotting did not reveal differences between control and MTG-treated bread protein extracts. Our results indicate that MTG treatment of wheat bread prepared with typical MTG concentrations used in standard bakery processes does not lead to immunodetectable amounts of CD immunotoxic deamidated gliadins.
The detector system of the Daya Bay reactor neutrino experiment
An, F. P.
2015-12-15
The Daya Bay experiment was the first to report simultaneous measurements of reactor antineutrinos at multiple baselines leading to the discovery of ν¯e oscillations over km-baselines. Subsequent data has provided the world's most precise measurement of sin 22θ 13 and the effective mass splitting Δm 2 ee. The experiment is located in Daya Bay, China where the cluster of six nuclear reactors is among the world's most prolific sources of electron antineutrinos. Multiple antineutrino detectors are deployed in three underground water pools at different distances from the reactor cores to search for deviations in the antineutrino rate and energy spectrummore » due to neutrino mixing. Instrumented with photomultiplier tubes, the water pools serve as shielding against natural radioactivity from the surrounding rock and provide efficient muon tagging. Arrays of resistive plate chambers over the top of each pool provide additional muon detection. The antineutrino detectors were specifically designed for measurements of the antineutrino flux with minimal systematic uncertainty. Relative detector efficiencies between the near and far detectors are known to better than 0.2%. With the unblinding of the final two detectors’ baselines and target masses, a complete description and comparison of the eight antineutrino detectors can now be presented. This study describes the Daya Bay detector systems, consisting of eight antineutrino detectors in three instrumented water pools in three underground halls, and their operation through the first year of eight detector data-taking.« less
Analytical probabilistic proton dose calculation and range uncertainties
NASA Astrophysics Data System (ADS)
Bangert, M.; Hennig, P.; Oelfke, U.
2014-03-01
We introduce the concept of analytical probabilistic modeling (APM) to calculate the mean and the standard deviation of intensity-modulated proton dose distributions under the influence of range uncertainties in closed form. For APM, range uncertainties are modeled with a multivariate Normal distribution p(z) over the radiological depths z. A pencil beam algorithm that parameterizes the proton depth dose d(z) with a weighted superposition of ten Gaussians is used. Hence, the integrals ∫ dz p(z) d(z) and ∫ dz p(z) d(z)2 required for the calculation of the expected value and standard deviation of the dose remain analytically tractable and can be efficiently evaluated. The means μk, widths δk, and weights ωk of the Gaussian components parameterizing the depth dose curves are found with least squares fits for all available proton ranges. We observe less than 0.3% average deviation of the Gaussian parameterizations from the original proton depth dose curves. Consequently, APM yields high accuracy estimates for the expected value and standard deviation of intensity-modulated proton dose distributions for two dimensional test cases. APM can accommodate arbitrary correlation models and account for the different nature of random and systematic errors in fractionated radiation therapy. Beneficial applications of APM in robust planning are feasible.
Ryan, Una; Lawler, Sheleigh; Reid, Simon
2017-02-01
Cryptosporidium is the leading cause of swimming pool outbreaks of gastroenteritis. Transmission occurs through the ingestion of oocysts that are passed in the faeces of an infected person or animal when an accidental faecal release event occurs. Cryptosporidium parasites present specific challenges for infection control as oocysts are highly resistant to chlorine levels used for pool disinfection, infected individuals can shed large numbers of oocysts, there is a long incubation period and shedding of oocysts occurs even after symptom resolution. The purposes of this review are to identify key barriers to limiting swimming pool-associated outbreaks of cryptosporidiosis and to outline needs for research and collaboration to advance co-ordinated management practices. We reviewed swimming pool-associated cryptosporidiosis outbreaks, disinfection teachniques, current regulations and the role of staff and patrons. Key barriers to limiting swimming pool-associated outbreaks of cryptosporidiosis are a lack of uniform national and international standards, poor adherence and understanding of regulations governing staff and patron behaviour, and low levels of public knowledge and awareness.
49 CFR 192.943 - When can an operator deviate from these reassessment intervals?
Code of Federal Regulations, 2010 CFR
2010-10-01
... (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.943 When can an operator deviate from these reassessment...
40 CFR 63.1455 - What reports must I submit and when?
Code of Federal Regulations, 2010 CFR
2010-07-01
... from any emission limitations (emission limit, operating limit, opacity limit) that applies to you and... that there were no deviations from the emission limitations, work practice standards, or operation and... deviation from an emission limitation (emission limit, operating limit, opacity limit) and for each...
Using an external gating signal to estimate noise in PET with an emphasis on tracer avid tumors
NASA Astrophysics Data System (ADS)
Schmidtlein, C. R.; Beattie, B. J.; Bailey, D. L.; Akhurst, T. J.; Wang, W.; Gönen, M.; Kirov, A. S.; Humm, J. L.
2010-10-01
The purpose of this study is to establish and validate a methodology for estimating the standard deviation of voxels with large activity concentrations within a PET image using replicate imaging that is immediately available for use in the clinic. To do this, ensembles of voxels in the averaged replicate images were compared to the corresponding ensembles in images derived from summed sinograms. In addition, the replicate imaging noise estimate was compared to a noise estimate based on an ensemble of voxels within a region. To make this comparison two phantoms were used. The first phantom was a seven-chamber phantom constructed of 1 liter plastic bottles. Each chamber of this phantom was filled with a different activity concentration relative to the lowest activity concentration with ratios of 1:1, 1:1, 2:1, 2:1, 4:1, 8:1 and 16:1. The second phantom was a GE Well-Counter phantom. These phantoms were imaged and reconstructed on a GE DSTE PET/CT scanner with 2D and 3D reprojection filtered backprojection (FBP), and with 2D- and 3D-ordered subset expectation maximization (OSEM). A series of tests were applied to the resulting images that showed that the region and replicate imaging methods for estimating standard deviation were equivalent for backprojection reconstructions. Furthermore, the noise properties of the FBP algorithms allowed scaling the replicate estimates of the standard deviation by a factor of 1/\\sqrt{N}, where N is the number of replicate images, to obtain the standard deviation of the full data image. This was not the case for OSEM image reconstruction. Due to nonlinearity of the OSEM algorithm, the noise is shown to be both position and activity concentration dependent in such a way that no simple scaling factor can be used to extrapolate noise as a function of counts. The use of the Well-Counter phantom contributed to the development of a heuristic extrapolation of the noise as a function of radius in FBP. In addition, the signal-to-noise ratio for high uptake objects was confirmed to be higher with backprojection image reconstruction methods. These techniques were applied to several patient data sets acquired in either 2D or 3D mode, with 18F (FLT and FDG). Images of the standard deviation and signal-to-noise ratios were constructed and the standard deviations of the tumors' uptake were determined. Finally, a radial noise extrapolation relationship deduced in this paper was applied to patient data.
Detecting long-duration cloud contamination in hyper-temporal NDVI imagery
NASA Astrophysics Data System (ADS)
Ali, Amjad; de Bie, C. A. J. M.; Skidmore, A. K.
2013-10-01
Cloud contamination impacts on the quality of hyper-temporal NDVI imagery and its subsequent interpretation. Short-duration cloud impacts are easily removed by using quality flags and an upper envelope filter, but long-duration cloud contamination of NDVI imagery remains. In this paper, an approach that goes beyond the use of quality flags and upper envelope filtering is tested to detect when and where long-duration clouds are responsible for unreliable NDVI readings, so that a user can flag those data as missing. The study is based on MODIS Terra and the combined Terra-Aqua 16-day NDVI product for the south of Ghana, where persistent cloud cover occurs throughout the year. The combined product could be assumed to have less cloud contamination, since it is based on two images per day. Short-duration cloud effects were removed from the two products through using the adaptive Savitzky-Golay filter. Then for each 'cleaned' product an unsupervised classified map was prepared using the ISODATA algorithm, and, by class, plots were prepared to depict changes over time of the means and the standard deviations in NDVI values. By comparing plots of similar classes, long-duration cloud contamination appeared to display a decline in mean NDVI below the lower limit 95% confidence interval with a coinciding increase in standard deviation above the upper limit 95% confidence interval. Regression analysis was carried out per NDVI class in two randomly selected groups in order to statistically test standard deviation values related to long-duration cloud contamination. A decline in seasonal NDVI values (growing season) were below the lower limit of 95% confidence interval as well as a concurrent increase in standard deviation values above the upper limit of the 95% confidence interval were noted in 34 NDVI classes. The regression analysis results showed that differences in NDVI class values between the Terra and the Terra-Aqua imagery were significantly correlated (p < 0.05) with the corresponding standard deviation values of the Terra imagery in case of all NDVI classes of two selected NDVI groups. The method successfully detects long-duration cloud contamination that results in unreliable NDVI values. The approach offers scientists interested in time series analysis a method of masking by area (class) the periods when pre-cleaned NDVI values remain affected by clouds. The approach requires no additional data for execution purposes but involves unsupervised classification of the imagery to carry out the evaluation of class-specific mean NDVI and standard deviation values over time.
Pandit, Jaideep J; Dexter, Franklin
2009-06-01
At multiple facilities including some in the United Kingdom's National Health Service, the following are features of many surgical-anesthetic teams: i) there is sufficient workload for each operating room (OR) list to almost always be fully scheduled; ii) the workdays are organized such that a single surgeon is assigned to each block of time (usually 8 h); iii) one team is assigned per block; and iv) hardly ever would a team "split" to do cases in more than one OR simultaneously. We used Monte-Carlo simulation using normal and Weibull distributions to estimate the times to complete lists of cases scheduled into such 8 h sessions. For each combination of mean and standard deviation, inefficiencies of use of OR time were determined for 10 h versus 8 h of staffing. When the mean actual hours of OR time used averages < or = 8 h 25 min, 8 h of staffing has higher OR efficiency than 10 h for all combinations of standard deviation and relative cost of over-run to under-run. When mean > or = 8 h 50 min, 10 h staffing has higher OR efficiency. For 8 h 25 min < mean < 8 h 50 min, the economic break-even point depends on conditions. For example, break-even is: (a) 8 h 27 min for Weibull, standard deviation of 60 min and relative cost of over-run to under-run of 2.0 versus (b) 8 h 48 min for normal, standard deviation of 0 min and relative cost ratio of 1.50. Although the simplest decision rule would be to staff for 8 h if the mean workload is < or = 8 h 40 min and to staff for 10 h otherwise, performance was poor. For example, for the Weibull distribution with mean 8 h 40 min, standard deviation 60 min, and relative cost ratio of 2.00, the inefficiency of use of OR time would be 34% larger if staffing were planned for 8 h instead of 10 h. For surgical teams with 8 h sessions, use the following decision rule for anesthesiology and OR nurse staffing. If actual hours of OR time used averages < or = 8 h 25 min, plan 8 h staffing. If average > or = 8 h 50 min, plan 10 h staffing. For averages in between, perform the full analysis of McIntosh et al. (Anesth Analg 2006;103:1499-516).
Multi-technique comparison of troposphere zenith delays and gradients during CONT08
NASA Astrophysics Data System (ADS)
Teke, Kamil; Böhm, Johannes; Nilsson, Tobias; Schuh, Harald; Steigenberger, Peter; Dach, Rolf; Heinkelmann, Robert; Willis, Pascal; Haas, Rüdiger; García-Espada, Susana; Hobiger, Thomas; Ichikawa, Ryuichi; Shimizu, Shingo
2011-07-01
CONT08 was a 15 days campaign of continuous Very Long Baseline Interferometry (VLBI) sessions during the second half of August 2008 carried out by the International VLBI Service for Geodesy and Astrometry (IVS). In this study, VLBI estimates of troposphere zenith total delays (ZTD) and gradients during CONT08 were compared with those derived from observations with the Global Positioning System (GPS), Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS), and water vapor radiometers (WVR) co-located with the VLBI radio telescopes. Similar geophysical models were used for the analysis of the space geodetic data, whereas the parameterization for the least-squares adjustment of the space geodetic techniques was optimized for each technique. In addition to space geodetic techniques and WVR, ZTD and gradients from numerical weather models (NWM) were used from the European Centre for Medium-Range Weather Forecasts (ECMWF) (all sites), the Japan Meteorological Agency (JMA) and Cloud Resolving Storm Simulator (CReSS) (Tsukuba), and the High Resolution Limited Area Model (HIRLAM) (European sites). Biases, standard deviations, and correlation coefficients were computed between the troposphere estimates of the various techniques for all eleven CONT08 co-located sites. ZTD from space geodetic techniques generally agree at the sub-centimetre level during CONT08, and—as expected—the best agreement is found for intra-technique comparisons: between the Vienna VLBI Software and the combined IVS solutions as well as between the Center for Orbit Determination (CODE) solution and an IGS PPP time series; both intra-technique comparisons are with standard deviations of about 3-6 mm. The best inter space geodetic technique agreement of ZTD during CONT08 is found between the combined IVS and the IGS solutions with a mean standard deviation of about 6 mm over all sites, whereas the agreement with numerical weather models is between 6 and 20 mm. The standard deviations are generally larger at low latitude sites because of higher humidity, and the latter is also the reason why the standard deviations are larger at northern hemisphere stations during CONT08 in comparison to CONT02 which was observed in October 2002. The assessment of the troposphere gradients from the different techniques is not as clear because of different time intervals, different estimation properties, or different observables. However, the best inter-technique agreement is found between the IVS combined gradients and the GPS solutions with standard deviations between 0.2 and 0.7 mm.
Aaltonen, T; Álvarez González, B; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Appel, J A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Auerbach, B; Aurisano, A; Azfar, F; Badgett, W; Bae, T; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauce, M; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Binkley, M E; Bisello, D; Bizjak, I; Bland, K R; Blumenfeld, B; Bocci, A; Bodek, A; Bortoletto, D; Boudreau, J; Boveia, A; Brigliadori, L; Bromberg, C; Brucken, E; Budagov, J; Budd, H S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Calamba, A; Calancha, C; Camarda, S; Campanelli, M; Campbell, M; Canelli, F; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chung, W H; Chung, Y S; Ciocci, M A; Clark, A; Clarke, C; Compostella, G; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Crescioli, F; Cuevas, J; Culbertson, R; Dagenhart, D; d'Ascenzo, N; Datta, M; de Barbaro, P; Dell'Orso, M; Demortier, L; Deninno, M; Devoto, F; d'Errico, M; Di Canto, A; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Dorigo, M; Dorigo, T; Ebina, K; Elagin, A; Eppig, A; Erbacher, R; Errede, S; Ershaidat, N; Eusebi, R; Farrington, S; Feindt, M; Fernandez, J P; Ferrazza, C; Field, R; Flanagan, G; Forrest, R; Frank, M J; Franklin, M; Freeman, J C; Funakoshi, Y; Furic, I; Gallinaro, M; Garcia, J E; Garfinkel, A F; Garosi, P; Gerberich, H; Gerchtein, E; Giagu, S; Giakoumopoulou, V; Giannetti, P; Gibson, K; Ginsburg, C M; Giokaris, N; Giromini, P; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldin, D; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Grinstein, S; Grosso-Pilcher, C; Group, R C; Guimaraes da Costa, J; Hahn, S R; Halkiadakis, E; Hamaguchi, A; Han, J Y; Happacher, F; Hara, K; Hare, D; Hare, M; Harr, R F; Hatakeyama, K; Hays, C; Heck, M; Heinrich, J; Herndon, M; Hewamanage, S; Hocker, A; Hopkins, W; Horn, D; Hou, S; Hughes, R E; Hurwitz, M; Husemann, U; Hussain, N; Hussein, M; Huston, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeans, D T; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kamon, T; Karchin, P E; Kasmi, A; Kato, Y; Ketchum, W; Keung, J; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kim, Y J; Kimura, N; Kirby, M; Klimenko, S; Knoepfel, K; Kondo, K; Kong, D J; Konigsberg, J; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Kruse, M; Krutelyov, V; Kuhr, T; Kurata, M; Kwang, S; Laasanen, A T; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; LeCompte, T; Lee, E; Lee, H S; Lee, J S; Lee, S W; Leo, S; Leone, S; Lewis, J D; Limosani, A; Lin, C-J; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, C; Liu, H; Liu, Q; Liu, T; Lockwitz, S; Loginov, A; Lucchesi, D; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Madrak, R; Maeshima, K; Maestro, P; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Marino, C; Martínez, M; Mastrandrea, P; Matera, K; Mattson, M E; Mazzacane, A; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Mesropian, C; Miao, T; Mietlicki, D; Mitra, A; Miyake, H; Moed, S; Moggi, N; Mondragon, M N; Moon, C S; Moore, R; Morello, M J; Morlock, J; Movilla Fernandez, P; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakano, I; Napier, A; Nett, J; Neu, C; Neubauer, M S; Nielsen, J; Nodulman, L; Noh, S Y; Norniella, O; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Ortolan, L; Pagan Griso, S; Pagliarone, C; Palencia, E; Papadimitriou, V; Paramonov, A A; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Pianori, E; Pilot, J; Pitts, K; Plager, C; Pondrom, L; Poprocki, S; Potamianos, K; Prokoshin, F; Pranko, A; Ptohos, F; Punzi, G; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Renton, P; Rescigno, M; Riddick, T; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rodriguez, T; Rogers, E; Rolli, S; Roser, R; Ruffini, F; Ruiz, A; Russ, J; Rusu, V; Safonov, A; Sakumoto, W K; Sakurai, Y; Santi, L; Sato, K; Saveliev, V; Savoy-Navarro, A; Schlabach, P; Schmidt, A; Schmidt, E E; Schwarz, T; Scodellaro, L; Scribano, A; Scuri, F; Seidel, S; Seiya, Y; Semenov, A; Sforza, F; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shreyber-Tecker, I; Simonenko, A; Sinervo, P; Sliwa, K; Smith, J R; Snider, F D; Soha, A; Sorin, V; Song, H; Squillacioti, P; Stancari, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Strycker, G L; Sudo, Y; Sukhanov, A; Suslov, I; Takemasa, K; Takeuchi, Y; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thome, J; Thompson, G A; Thomson, E; Tipton, P; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Trovato, M; Ukegawa, F; Uozumi, S; Varganov, A; Vázquez, F; Velev, G; Vellidis, C; Vidal, M; Vila, I; Vilar, R; Vizán, J; Vogel, M; Volpi, G; Wagner, P; Wagner, R L; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Wester, W C; Whiteson, D; Wicklund, A B; Wicklund, E; Wilbur, S; Wick, F; Williams, H H; Wilson, J S; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, H; Wright, T; Wu, X; Wu, Z; Yamamoto, K; Yamato, D; Yang, T; Yang, U K; Yang, Y C; Yao, W-M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanetti, A; Zeng, Y; Zhou, C; Zucchelli, S
2012-09-14
We combine the results of searches for the standard model (SM) Higgs boson based on the full CDF Run II data set obtained from sqrt[s]=1.96 TeV pp collisions at the Fermilab Tevatron corresponding to an integrated luminosity of 9.45 fb(-1). The searches are conducted for Higgs bosons that are produced in association with a W or Z boson, have masses in the range 90-150 GeV/c(2), and decay into bb pairs. An excess of data is present that is inconsistent with the background prediction at the level of 2.5 standard deviations (the most significant local excess is 2.7 standard deviations).
Persistence of depressive symptoms and gait speed recovery in older adults after hip fracture.
Rathbun, Alan M; Shardell, Michelle D; Stuart, Elizabeth A; Gruber-Baldini, Ann L; Orwig, Denise; Ostir, Glenn V; Hicks, Gregory E; Hochberg, Marc C; Magaziner, Jay
2018-07-01
Depression after hip fracture in older adults is associated with worse physical performance; however, depressive symptoms are dynamic, fluctuating during the recovery period. The study aim was to determine how the persistence of depressive symptoms over time cumulatively affects the recovery of physical performance. Marginal structural models estimated the cumulative effect of persistence of depressive symptoms on gait speed during hip fracture recovery among older adults (n = 284) enrolled in the Baltimore Hip Studies 7th cohort. Depressive symptoms at baseline and at 2-month and 6-month postadmission for hip fracture were evaluated by using the Center for Epidemiological Studies Depression Scale, and persistence of symptoms was assessed as a time-averaged severity lagged to standardized 3 m gait speed at 2, 6, and 12 months. A 1-unit increase in time-averaged Center for Epidemiological Studies Depression score was associated with a mean difference in gait speed of -0.0076 standard deviations (95% confidence interval [CI]: -0.0184, 0.0032; P = .166). The association was largest in magnitude from baseline to 6 months: -0.0144 standard deviations (95% CI: -0.0303, 0.0015; P = 0.076). Associations for the other time intervals were smaller: -0.0028 standard deviations (95% CI: -0.0138, 0.0083; P = .621) at 2 months and -0.0121 standard deviations (95% CI: -0.0324, 0.0082; P = .238) at 12 months. Although not statistically significant, the magnitude of the numerical estimates suggests that expressing more depressive symptoms during the first 6 months after hip fracture has a meaningful impact on functional recovery. Copyright © 2018 John Wiley & Sons, Ltd.
Hendriks, A Jan; Awkerman, Jill A; de Zwart, Dick; Huijbregts, Mark A J
2013-11-01
While variable sensitivity of model species to common toxicants has been addressed in previous studies, a systematic analysis of inter-species variability for different test types, modes of action and species is as of yet lacking. Hence, the aim of the present study was to identify similarities and differences in contaminant levels affecting cold-blooded and warm-blooded species administered via different routes. To that end, data on lethal water concentrations LC50, tissue residues LR50 and oral doses LD50 were collected from databases, each representing the largest of its kind. LC50 data were multiplied by a bioconcentration factor (BCF) to convert them to internal concentrations that allow for comparison among species. For each endpoint data set, we calculated the mean and standard deviation of species' lethal level per compound. Next, the means and standard deviations were averaged by mode of action. Both the means and standard deviations calculated depended on the number of species tested, which is at odds with quality standard setting procedures. Means calculated from (BCF) LC50, LR50 and LD50 were largely similar, suggesting that different administration routes roughly yield similar internal levels. Levels for compounds interfering biochemically with elementary life processes were about one order of magnitude below that of narcotics disturbing membranes, and neurotoxic pesticides and dioxins induced death in even lower amounts. Standard deviations for LD50 data were similar across modes of action, while variability of LC50 values was lower for narcotics than for substances with a specific mode of action. The study indicates several directions to go for efficient use of available data in risk assessment and reduction of species testing. Copyright © 2013 Elsevier Inc. All rights reserved.
Technology research for strapdown inertial experiment and digital flight control and guidance
NASA Technical Reports Server (NTRS)
Carestia, R. A.; Cottrell, D. E.
1985-01-01
A helicopter flight-test program to evaluate the performance of Honeywell's Tetrad - a strapdown, laser gyro, inertial navitation system is discussed. The results of 34 flights showed a mean final navigational velocity error of 5.06 knots, with a standard deviation of 3.84 knots; a corresponding mean final position error of 2.66 n.mi., with a standard deviation of 1.48 n.m.; and a modeled mean-position-error growth rate for the 34 tests of 1.96 knots, with a standard deviation of 1.09 knots. Tetrad's four-ring laser gyros provided reliable and accurate angular rate sensing during the test program and on sensor failures were detected during the evaluation. Criteria suitable for investigating cockpit systems in rotorcraft were developed. This criteria led to the development of two basic simulators. The first was a standard simulator which could be used to obtain baseline information for studying pilot workload and interactions. The second was an advanced simulator which integrated the RODAAS developed by Honeywell into this simulator. The second area also included surveying the aerospace industry to determine the level of use and impact of microcomputers and related components on avionics systems.
The Bnl Muon Anomalous Magnetic Moment Measurement
NASA Astrophysics Data System (ADS)
Hertzog, David W.
2003-09-01
The E821 experiment at Brookhaven National Laboratory is designed to measure the muon magnetic anomaly, aμ, to an ultimate precision of 0.4 parts per million (ppm). Because theory can predict aμ to 0.6 ppm, and ongoing efforts aim to reduce this uncertainty, the comparison represents an important and sensitive test of new physics. At the time of this Workshop, the reported experimental result from the 1999 running period achieved a
7 CFR 32.400 - Samples of grease mohair grades; method of obtaining.
Code of Federal Regulations, 2010 CFR
2010-01-01
... standard deviation of fiber diameter of bulk sample were within the limits corresponding to the grade of... SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER REGULATIONS PURCHASE OF GREASE MOHAIR AND MOHAIR TOP SAMPLES § 32.400 Samples of grease...
7 CFR 31.400 - Samples for wool and wool top grades; method of obtaining.
Code of Federal Regulations, 2010 CFR
2010-01-01
... average and standard deviation of fiber diameter of the bulk sample are within the limits corresponding to... MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER REGULATIONS PURCHASE OF WOOL AND WOOL TOP SAMPLES § 31.400 Samples for wool...
49 CFR 192.913 - When may an operator deviate its program from certain requirements of this subpart?
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.913 When may an operator deviate its program...
Organizational Deviance and Multi-Factor Leadership
ERIC Educational Resources Information Center
Aksu, Ali
2016-01-01
Organizational deviant behaviors can be defined as behaviors that have deviated from standards and uncongenial to organization's expectations. When such behaviors have been thought to damage the organization, it can be said that reducing the deviation behaviors at minimum level is necessary for a healthy organization. The aim of this research is…
21 CFR 600.14 - Reporting of biological product deviations by licensed manufacturers.
Code of Federal Regulations, 2011 CFR
2011-04-01
... this section? (1) You, the manufacturer who holds the biological product license and who had control... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Reporting of biological product deviations by... HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS BIOLOGICAL PRODUCTS: GENERAL Establishment Standards...
Observation of electroweak single top-quark production.
Aaltonen, T; Adelman, J; Akimoto, T; Alvarez González, B; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Apresyan, A; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Aurisano, A; Azfar, F; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartsch, V; Bauer, G; Beauchemin, P-H; Bedeschi, F; Beecher, D; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Beringer, J; Bhatti, A; Binkley, M; Bisello, D; Bizjak, I; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Bridgeman, A; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Burke, S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Byrum, K L; Cabrera, S; Calancha, C; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chou, J P; Choudalakis, G; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Chwalek, T; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Compostella, G; Convery, M E; Conway, J; Cordelli, M; Cortiana, G; Cox, C A; Cox, D J; Crescioli, F; Cuenca Almenar, C; Cuevas, J; Culbertson, R; Cully, J C; Dagenhart, D; Datta, M; Davies, T; de Barbaro, P; De Cecco, S; Deisher, A; De Lorenzo, G; Dell'orso, M; Deluca, C; Demortier, L; Deng, J; Deninno, M; Derwent, P F; Di Canto, P; di Giovanni, G P; Dionisi, C; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Donini, J; Dorigo, T; Dube, S; Efron, J; Elagin, A; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Ferrazza, C; Field, R; Flanagan, G; Forrest, R; Frank, M J; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garberson, F; Garcia, J E; Garfinkel, A F; Garosi, P; Genser, K; Gerberich, H; Gerdes, D; Gessler, A; Giagu, S; Giakoumopoulou, V; Giannetti, P; Gibson, K; Gimmell, J L; Ginsburg, C M; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Grinstein, S; Grosso-Pilcher, C; Grundler, U; Guimaraes da Costa, J; Gunay-Unalan, Z; Haber, C; Hahn, K; Hahn, S R; Halkiadakis, E; Han, B-Y; Han, J Y; Happacher, F; Hara, K; Hare, D; Hare, M; Harper, S; Harr, R F; Harris, R M; Hartz, M; Hatakeyama, K; Hays, C; Heck, M; Heijboer, A; Heinrich, J; Henderson, C; Herndon, M; Heuser, J; Hewamanage, S; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Husemann, U; Hussein, M; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jha, M K; Jindariani, S; Johnson, W; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Kar, D; Karchin, P E; Kato, Y; Kephart, R; Keung, J; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, H W; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Knuteson, B; Ko, B R; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Krumnack, N; Kruse, M; Krutelyov, V; Kubo, T; Kuhr, T; Kulkarni, N P; Kurata, M; Kwang, S; Laasanen, A T; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; LeCompte, T; Lee, E; Lee, H S; Lee, S W; Leone, S; Lewis, J D; Lin, C-S; Linacre, J; Lindgren, M; Lipeles, E; Liss, T M; Lister, A; Litvintsev, D O; Liu, C; Liu, T; Lockyer, N S; Loginov, A; Loreti, M; Lovas, L; Lucchesi, D; Luci, C; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; MacQueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maki, T; Maksimovic, P; Malde, S; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Marino, C; Marino, C P; Martin, A; Martin, V; Martínez, M; Martínez-Ballarín, R; Maruyama, T; Mastrandrea, P; Masubuchi, T; Mathis, M; Mattson, M E; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzione, A; Merkel, P; Mesropian, C; Miao, T; Miladinovic, N; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyake, H; Moggi, N; Moon, C S; Moore, R; Morello, M J; Morlock, J; Movilla Fernandez, P; Mülmenstädt, J; Mukherjee, A; Muller, Th; Mumford, R; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Nagano, A; Naganoma, J; Nakamura, K; Nakano, I; Napier, A; Necula, V; Nett, J; Neu, C; Neubauer, M S; Neubauer, S; Nielsen, J; Nodulman, L; Norman, M; Norniella, O; Nurse, E; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Osterberg, K; Pagan Griso, S; Palencia, E; Papadimitriou, V; Papaikonomou, A; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Peiffer, T; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Pianori, E; Pinera, L; Pitts, K; Plager, C; Pondrom, L; Potamianos, K; Poukhov, O; Pounder, N; Prakoshyn, F; Pronko, A; Proudfoot, J; Ptohos, F; Pueschel, E; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Renton, P; Renz, M; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rodriguez, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Roy, P; Ruiz, A; Russ, J; Rusu, V; Rutherford, B; Saarikko, H; Safonov, A; Sakumoto, W K; Saltó, O; Santi, L; Sarkar, S; Sartori, L; Sato, K; Savoy-Navarro, A; Schlabach, P; Schmidt, A; Schmidt, E E; Schmidt, M A; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sforza, F; Sfyrla, A; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shiraishi, S; Shochet, M; Shon, Y; Shreyber, I; Sinervo, P; Sisakyan, A; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spreitzer, T; Squillacioti, P; Stanitzki, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Strycker, G L; Stuart, D; Suh, J S; Sukhanov, A; Suslov, I; Suzuki, T; Taffard, A; Takashima, R; Takeuchi, Y; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Thom, J; Thompson, A S; Thompson, G A; Thomson, E; Tipton, P; Ttito-Guzmán, P; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Tourneur, S; Trovato, M; Tsai, S-Y; Tu, Y; Turini, N; Ukegawa, F; Vallecorsa, S; van Remortel, N; Varganov, A; Vataga, E; Vázquez, F; Velev, G; Vellidis, C; Vidal, M; Vidal, R; Vila, I; Vilar, R; Vine, T; Vogel, M; Volobouev, I; Volpi, G; Wagner, P; Wagner, R G; Wagner, R L; Wagner, W; Wagner-Kuhr, J; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Weinberger, M; Weinelt, J; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Wilbur, S; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wright, T; Wu, X; Würthwein, F; Xie, S; Yagil, A; Yamamoto, K; Yamaoka, J; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zhang, X; Zheng, Y; Zucchelli, S
2009-08-28
We report the observation of single top-quark production using 3.2 fb(-1) of pp[over ] collision data with sqrt[s]=1.96 TeV collected by the Collider Detector at Fermilab. The significance of the observed data is 5.0 standard deviations, and the expected sensitivity for standard model production and decay is in excess of 5.9 standard deviations. Assuming m(t) = 175 GeV/c(2), we measure a cross section of 2.3(-0.5);(+0.6)(stat + syst) pb, extract the CKM matrix-element value |V(tb)| = 0.91 + or - 0.11(stat + syst) + or - 0.07(theory), and set the limit |V(tb)| > 0.71 at the 95% C.L.
Méndez-Hermida, F.; Castro-Hermida, J. A.; Ares-Mazás, E.; Kehoe, S. C.; McGuigan, K. G.
2005-01-01
The results of batch-process solar disinfection (SODIS) of Cryptosporidium parvum oocysts in water are reported. Oocyst suspensions were exposed to simulated sunlight (830 W m−2) at 40°C. Viability assays (4′,6′-diamidino-2-phenylindole [DAPI]/propidium iodide and excystation) and infectivity tests (Swiss CD-1 suckling mice) were performed. SODIS exposures of 6 and 12 h reduced oocyst infectivity from 100% to 7.5% (standard deviation = 2.3) and 0% (standard deviation = 0.0), respectively. PMID:15746372
Reliability-Based Design Optimization of a Composite Airframe Component
NASA Technical Reports Server (NTRS)
Pai, Shantaram S.; Coroneos, Rula; Patnaik, Surya N.
2011-01-01
A stochastic optimization methodology (SDO) has been developed to design airframe structural components made of metallic and composite materials. The design method accommodates uncertainties in load, strength, and material properties that are defined by distribution functions with mean values and standard deviations. A response parameter, like a failure mode, has become a function of reliability. The primitive variables like thermomechanical loads, material properties, and failure theories, as well as variables like depth of beam or thickness of a membrane, are considered random parameters with specified distribution functions defined by mean values and standard deviations.
Is there a link between cognitive abilities and environmental awareness? Cross-national evidence.
Salahodjaev, Raufhon
2018-06-05
This article explores the effect of cognitive abilities on environmental awareness using data from 119 countries for the period 2005-2015. Our findings provide pioneering confirmation that a facet of human psychology, namely cognitive ability, is positively associated with environmentalism. The empirical estimations indicate that when cognitive abilities increase by one standard deviation, climate change awareness increases by approximately 19% (slightly less than one standard deviation). This positive association remains intact when we control for other determinants of environmentalism. Copyright © 2018 Elsevier Inc. All rights reserved.
Range and Energy Straggling in Ion Beam Transport
NASA Technical Reports Server (NTRS)
Wilson, John W.; Tai, Hsiang
2000-01-01
A first-order approximation to the range and energy straggling of ion beams is given as a normal distribution for which the standard deviation is estimated from the fluctuations in energy loss events. The standard deviation is calculated by assuming scattering from free electrons with a long range cutoff parameter that depends on the mean excitation energy of the medium. The present formalism is derived by extrapolating Payne's formalism to low energy by systematic energy scaling and to greater depths of penetration by a second-order perturbation. Limited comparisons are made with experimental data.
Posttraumatic stress disorder and dementia in Holocaust survivors.
Sperling, Wolfgang; Kreil, Sebastian Konstantin; Biermann, Teresa
2011-03-01
The incidence of mental and somatic sequelae has been shown to be very high in the group of people damaged by the Holocaust. Within the context of internal research, 93 Holocaust survivors suffering from posttraumatic stress disorder have been examined. Patients suffered on average from 4.5 (standard deviation ± 1.8) somatic diagnoses as well as 1.8 (standard deviation ± 0.5) psychiatric diagnoses. A diagnosis of dementia was ascertained according to ICD-10 criteria in 14%. Vascular dementia (66%) dominated over Alzheimer's dementia (23%) and other subtypes (11%).
NASA Astrophysics Data System (ADS)
Osipova, Irina Y.; Chyzh, Igor H.
2001-06-01
The influence of eye jumps on the accuracy of estimation of Zernike coefficients from eye transverse aberration measurements was investigated. By computer modeling the ametropy and astigmatism have been examined. The standard deviation of the wave aberration function was calculated. It was determined that the standard deviation of the wave aberration function achieves the minimum value if the number of scanning points is equal to the number of eye jumps in scanning period. The recommendations for duration of measurement were worked out.
Observation of the Higgs boson decay to a pair of τ leptons with the CMS detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sirunyan, A. M.; Tumasyan, A.; Adam, W.
Here, a measurement of the H → ττ signal strength is performed using events recorded in proton–proton collisions by the CMS experiment at the LHC in 2016 at a center-of-mass energy of 13 TeV. The data set corresponds to an integrated luminosity of 35.9 fb -1. The H → ττ signal is established with a significance of 4.9 standard deviations, to be compared to an expected significance of 4.7 standard deviations.
Discrete disorder models for many-body localization
NASA Astrophysics Data System (ADS)
Janarek, Jakub; Delande, Dominique; Zakrzewski, Jakub
2018-04-01
Using exact diagonalization technique, we investigate the many-body localization phenomenon in the 1D Heisenberg chain comparing several disorder models. In particular we consider a family of discrete distributions of disorder strengths and compare the results with the standard uniform distribution. Both statistical properties of energy levels and the long time nonergodic behavior are discussed. The results for different discrete distributions are essentially identical to those obtained for the continuous distribution, provided the disorder strength is rescaled by the standard deviation of the random distribution. Only for the binary distribution significant deviations are observed.
Observation of the Higgs boson decay to a pair of τ leptons with the CMS detector
Sirunyan, A. M.; Tumasyan, A.; Adam, W.; ...
2018-02-07
Here, a measurement of the H → ττ signal strength is performed using events recorded in proton–proton collisions by the CMS experiment at the LHC in 2016 at a center-of-mass energy of 13 TeV. The data set corresponds to an integrated luminosity of 35.9 fb -1. The H → ττ signal is established with a significance of 4.9 standard deviations, to be compared to an expected significance of 4.7 standard deviations.
Aad, G; Abbott, B; Abdallah, J; Abdel Khalek, S; Abdelalim, A A; Abdesselam, A; Abdinov, O; Abi, B; Abolins, M; Abouzeid, O S; Abramowicz, H; Abreu, H; Acerbi, E; Acharya, B S; Adamczyk, L; Adams, D L; Addy, T N; Adelman, J; Aderholz, M; Adomeit, S; Adragna, P; Adye, T; Aefsky, S; Aguilar-Saavedra, J A; Aharrouche, M; Ahlen, S P; Ahles, F; Ahmad, A; Ahsan, M; Aielli, G; Akdogan, T; Akesson, T P A; Akimoto, G; Akimov, A V; Akiyama, A; Alam, M S; Alam, M A; Albert, J; Albrand, S; Aleksa, M; Aleksandrov, I N; Alessandria, F; Alexa, C; Alexander, G; Alexandre, G; Alexopoulos, T; Alhroob, M; Aliev, M; Alimonti, G; Alison, J; Aliyev, M; Allbrooke, B M M; Allport, P P; Allwood-Spiers, S E; Almond, J; Aloisio, A; Alon, R; Alonso, A; Alvarez Gonzalez, B; Alviggi, M G; Amako, K; Amaral, P; Amelung, C; Ammosov, V V; Amorim, A; Amorós, G; Amram, N; Anastopoulos, C; Ancu, L S; Andari, N; Andeen, T; Anders, C F; Anders, G; Anderson, K J; Andreazza, A; Andrei, V; Andrieux, M-L; Anduaga, X S; Angerami, A; Anghinolfi, F; Anisenkov, A; Anjos, N; Annovi, A; Antonaki, A; Antonelli, M; Antonov, A; Antos, J; Anulli, F; Aoun, S; Aperio Bella, L; Apolle, R; Arabidze, G; Aracena, I; Arai, Y; Arce, A T H; Arfaoui, S; Arguin, J-F; Arik, E; Arik, M; Armbruster, A J; Arnaez, O; Arnal, V; Arnault, C; Artamonov, A; Artoni, G; Arutinov, D; Asai, S; Asfandiyarov, R; Ask, S; Asman, B; Asquith, L; Assamagan, K; Astbury, A; Astvatsatourov, A; Aubert, B; Auge, E; Augsten, K; Aurousseau, M; Avolio, G; Avramidou, R; Axen, D; Ay, C; Azuelos, G; Azuma, Y; Baak, M A; Baccaglioni, G; Bacci, C; Bach, A M; Bachacou, H; Bachas, K; Backes, M; Backhaus, M; Badescu, E; Bagnaia, P; Bahinipati, S; Bai, Y; Bailey, D C; Bain, T; Baines, J T; Baker, O K; Baker, M D; Baker, S; Banas, E; Banerjee, P; Banerjee, Sw; Banfi, D; Bangert, A; Bansal, V; Bansil, H S; Barak, L; Baranov, S P; Barashkou, A; Barbaro Galtieri, A; Barber, T; Barberio, E L; Barberis, D; Barbero, M; Bardin, D Y; Barillari, T; Barisonzi, M; Barklow, T; Barlow, N; Barnett, B M; Barnett, R M; Baroncelli, A; Barone, G; Barr, A J; Barreiro, F; Barreiro Guimarães da Costa, J; Barrillon, P; Bartoldus, R; Barton, A E; Bartsch, V; Bates, R L; Batkova, L; Batley, J R; Battaglia, A; Battistin, M; Bauer, F; Bawa, H S; Beale, S; Beau, T; Beauchemin, P H; Beccherle, R; Bechtle, P; Beck, H P; Becker, S; Beckingham, M; Becks, K H; Beddall, A J; Beddall, A; Bedikian, S; Bednyakov, V A; Bee, C P; Begel, M; Behar Harpaz, S; Behera, P K; Beimforde, M; Belanger-Champagne, C; Bell, P J; Bell, W H; Bella, G; Bellagamba, L; Bellina, F; Bellomo, M; Belloni, A; Beloborodova, O; Belotskiy, K; Beltramello, O; Benary, O; Benchekroun, D; Benchouk, C; Bendel, M; Benekos, N; Benhammou, Y; Benhar Noccioli, E; Benitez Garcia, J A; Benjamin, D P; Benoit, M; Bensinger, J R; Benslama, K; Bentvelsen, S; Berge, D; Bergeaas Kuutmann, E; Berger, N; Berghaus, F; Berglund, E; Beringer, J; Bernat, P; Bernhard, R; Bernius, C; Berry, T; Bertella, C; Bertin, A; Bertinelli, F; Bertolucci, F; Besana, M I; Besson, N; Bethke, S; Bhimji, W; Bianchi, R M; Bianco, M; Biebel, O; Bieniek, S P; Bierwagen, K; Biesiada, J; Biglietti, M; Bilokon, H; Bindi, M; Binet, S; Bingul, A; Bini, C; Biscarat, C; Bitenc, U; Black, K M; Blair, R E; Blanchard, J-B; Blanchot, G; Blazek, T; Blocker, C; Blocki, J; Blondel, A; Blum, W; Blumenschein, U; Bobbink, G J; Bobrovnikov, V B; Bocchetta, S S; Bocci, A; Boddy, C R; Boehler, M; Boek, J; Boelaert, N; Bogaerts, J A; Bogdanchikov, A; Bogouch, A; Bohm, C; Bohm, J; Boisvert, V; Bold, T; Boldea, V; Bolnet, N M; Bomben, M; Bona, M; Bondarenko, V G; Bondioli, M; Boonekamp, M; Booth, C N; Bordoni, S; Borer, C; Borisov, A; Borissov, G; Borjanovic, I; Borri, M; Borroni, S; Bortolotto, V; Bos, K; Boscherini, D; Bosman, M; Boterenbrood, H; Botterill, D; Bouchami, J; Boudreau, J; Bouhova-Thacker, E V; Boumediene, D; Bourdarios, C; Bousson, N; Boveia, A; Boyd, J; Boyko, I R; Bozhko, N I; Bozovic-Jelisavcic, I; Bracinik, J; Braem, A; Branchini, P; Brandenburg, G W; Brandt, A; Brandt, G; Brandt, O; Bratzler, U; Brau, B; Brau, J E; Braun, H M; Brelier, B; Bremer, J; Brenner, R; Bressler, S; Britton, D; Brochu, F M; Brock, I; Brock, R; Brodbeck, T J; Brodet, E; Broggi, F; Bromberg, C; Bronner, J; Brooijmans, G; Brooks, W K; Brown, G; Brown, H; Bruckman de Renstrom, P A; Bruncko, D; Bruneliere, R; Brunet, S; Bruni, A; Bruni, G; Bruschi, M; Buanes, T; Buat, Q; Bucci, F; Buchanan, J; Buchanan, N J; Buchholz, P; Buckingham, R M; Buckley, A G; Buda, S I; Budagov, I A; Budick, B; Büscher, V; Bugge, L; Bulekov, O; Bunse, M; Buran, T; Burckhart, H; Burdin, S; Burgess, T; Burke, S; Busato, E; Bussey, P; Buszello, C P; Butin, F; Butler, B; Butler, J M; Buttar, C M; Butterworth, J M; Buttinger, W; Cabrera Urbán, S; Caforio, D; Cakir, O; Calafiura, P; Calderini, G; Calfayan, P; Calkins, R; Caloba, L P; Caloi, R; Calvet, D; Calvet, S; Camacho Toro, R; Camarri, P; Cambiaghi, M; Cameron, D; Caminada, L M; Campana, S; Campanelli, M; Canale, V; Canelli, F; Canepa, A; Cantero, J; Capasso, L; Capeans Garrido, M D M; Caprini, I; Caprini, M; Capriotti, D; Capua, M; Caputo, R; Cardarelli, R; Carli, T; Carlino, G; Carminati, L; Caron, B; Caron, S; Carquin, E; Carrillo Montoya, G D; Carter, A A; Carter, J R; Carvalho, J; Casadei, D; Casado, M P; Cascella, M; Caso, C; Castaneda Hernandez, A M; Castaneda-Miranda, E; Castillo Gimenez, V; Castro, N F; Cataldi, G; Cataneo, F; Catinaccio, A; Catmore, J R; Cattai, A; Cattani, G; Caughron, S; Cauz, D; Cavalleri, P; Cavalli, D; Cavalli-Sforza, M; Cavasinni, V; Ceradini, F; Cerqueira, A S; Cerri, A; Cerrito, L; Cerutti, F; Cetin, S A; Cevenini, F; Chafaq, A; Chakraborty, D; Chan, K; Chapleau, B; Chapman, J D; Chapman, J W; Chareyre, E; Charlton, D G; Chavda, V; Chavez Barajas, C A; Cheatham, S; Chekanov, S; Chekulaev, S V; Chelkov, G A; Chelstowska, M A; Chen, C; Chen, H; Chen, S; Chen, T; Chen, X; Cheng, S; Cheplakov, A; Chepurnov, V F; Cherkaoui El Moursli, R; Chernyatin, V; Cheu, E; Cheung, S L; Chevalier, L; Chiefari, G; Chikovani, L; Childers, J T; Chilingarov, A; Chiodini, G; Chisholm, A S; Chislett, R T; Chizhov, M V; Choudalakis, G; Chouridou, S; Christidi, I A; Christov, A; Chromek-Burckhart, D; Chu, M L; Chudoba, J; Ciapetti, G; Ciftci, A K; Ciftci, R; Cinca, D; Cindro, V; Ciobotaru, M D; Ciocca, C; Ciocio, A; Cirilli, M; Citterio, M; Ciubancan, M; Clark, A; Clark, P J; Cleland, W; Clemens, J C; Clement, B; Clement, C; Clifft, R W; Coadou, Y; Cobal, M; Coccaro, A; Cochran, J; Coe, P; Cogan, J G; Coggeshall, J; Cogneras, E; Colas, J; Colijn, A P; Collard, C; Collins, N J; Collins-Tooth, C; Collot, J; Colon, G; Conde Muiño, P; Coniavitis, E; Conidi, M C; Consonni, M; Consonni, S M; Consorti, V; Constantinescu, S; Conta, C; Conti, G; Conventi, F; Cook, J; Cooke, M; Cooper, B D; Cooper-Sarkar, A M; Copic, K; Cornelissen, T; Corradi, M; Corriveau, F; Cortes-Gonzalez, A; Cortiana, G; Costa, G; Costa, M J; Costanzo, D; Costin, T; Côté, D; Coura Torres, R; Courneyea, L; Cowan, G; Cowden, C; Cox, B E; Cranmer, K; Crescioli, F; Cristinziani, M; Crosetti, G; Crupi, R; Crépé-Renaudin, S; Cuciuc, C-M; Cuenca Almenar, C; Cuhadar Donszelmann, T; Curatolo, M; Curtis, C J; Cuthbert, C; Cwetanski, P; Czirr, H; Czodrowski, P; Czyczula, Z; D'Auria, S; D'Onofrio, M; D'Orazio, A; Da Silva, P V M; Da Via, C; Dabrowski, W; Dai, T; Dallapiccola, C; Dam, M; Dameri, M; Damiani, D S; Danielsson, H O; Dannheim, D; Dao, V; Darbo, G; Darlea, G L; Davey, W; Davidek, T; Davidson, N; Davidson, R; Davies, E; Davies, M; Davison, A R; Davygora, Y; Dawe, E; Dawson, I; Dawson, J W; Daya, R K; De, K; de Asmundis, R; De Castro, S; De Castro Faria Salgado, P E; De Cecco, S; de Graat, J; De Groot, N; de Jong, P; De La Taille, C; De la Torre, H; De Lotto, B; de Mora, L; De Nooij, L; De Pedis, D; De Salvo, A; De Sanctis, U; De Santo, A; De Vivie De Regie, J B; De Zorzi, G; Dean, S; Dearnaley, W J; Debbe, R; Debenedetti, C; Dechenaux, B; Dedovich, D V; Degenhardt, J; Dehchar, M; Del Papa, C; Del Peso, J; Del Prete, T; Delemontex, T; Deliyergiyev, M; Dell'Acqua, A; Dell'Asta, L; Della Pietra, M; della Volpe, D; Delmastro, M; Delruelle, N; Delsart, P A; Deluca, C; Demers, S; Demichev, M; Demirkoz, B; Deng, J; Denisov, S P; Derendarz, D; Derkaoui, J E; Derue, F; Dervan, P; Desch, K; Devetak, E; Deviveiros, P O; Dewhurst, A; DeWilde, B; Dhaliwal, S; Dhullipudi, R; Di Ciaccio, A; Di Ciaccio, L; Di Girolamo, A; Di Girolamo, B; Di Luise, S; Di Mattia, A; Di Micco, B; Di Nardo, R; Di Simone, A; Di Sipio, R; Diaz, M A; Diblen, F; Diehl, E B; Dietrich, J; Dietzsch, T A; Diglio, S; Dindar Yagci, K; Dingfelder, J; Dionisi, C; Dita, P; Dita, S; Dittus, F; Djama, F; Djobava, T; do Vale, M A B; Do Valle Wemans, A; Doan, T K O; Dobbs, M; Dobinson, R; Dobos, D; Dobson, E; Dobson, M; Dodd, J; Doglioni, C; Doherty, T; Doi, Y; Dolejsi, J; Dolenc, I; Dolezal, Z; Dolgoshein, B A; Dohmae, T; Donadelli, M; Donega, M; Donini, J; Dopke, J; Doria, A; Dos Anjos, A; Dosil, M; Dotti, A; Dova, M T; Dowell, J D; Doxiadis, A D; Doyle, A T; Drasal, Z; Drees, J; Dressnandt, N; Drevermann, H; Driouichi, C; Dris, M; Dubbert, J; Dube, S; Duchovni, E; Duckeck, G; Dudarev, A; Dudziak, F; Dührssen, M; Duerdoth, I P; Duflot, L; Dufour, M-A; Dunford, M; Duran Yildiz, H; Duxfield, R; Dwuznik, M; Dydak, F; Düren, M; Ebenstein, W L; Ebke, J; Eckweiler, S; Edmonds, K; Edwards, C A; Edwards, N C; Ehrenfeld, W; Ehrich, T; Eifert, T; Eigen, G; Einsweiler, K; Eisenhandler, E; Ekelof, T; El Kacimi, M; Ellert, M; Elles, S; Ellinghaus, F; Ellis, K; Ellis, N; Elmsheuser, J; Elsing, M; Emeliyanov, D; Engelmann, R; Engl, A; Epp, B; Eppig, A; Erdmann, J; Ereditato, A; Eriksson, D; Ernst, J; Ernst, M; Ernwein, J; Errede, D; Errede, S; Ertel, E; Escalier, M; Escobar, C; Espinal Curull, X; Esposito, B; Etienne, F; Etienvre, A I; Etzion, E; Evangelakou, D; Evans, H; Fabbri, L; Fabre, C; Fakhrutdinov, R M; Falciano, S; Fang, Y; Fanti, M; Farbin, A; Farilla, A; Farley, J; Farooque, T; Farrell, S; Farrington, S M; Farthouat, P; Fassnacht, P; Fassouliotis, D; Fatholahzadeh, B; Favareto, A; Fayard, L; Fazio, S; Febbraro, R; Federic, P; Fedin, O L; Fedorko, W; Fehling-Kaschek, M; Feligioni, L; Fellmann, D; Feng, C; Feng, E J; Fenyuk, A B; Ferencei, J; Ferland, J; Fernando, W; Ferrag, S; Ferrando, J; Ferrara, V; Ferrari, A; Ferrari, P; Ferrari, R; Ferreira de Lima, D E; Ferrer, A; Ferrer, M L; Ferrere, D; Ferretti, C; Ferretto Parodi, A; Fiascaris, M; Fiedler, F; Filipčič, A; Filippas, A; Filthaut, F; Fincke-Keeler, M; Fiolhais, M C N; Fiorini, L; Firan, A; Fischer, G; Fischer, P; Fisher, M J; Flechl, M; Fleck, I; Fleckner, J; Fleischmann, P; Fleischmann, S; Flick, T; Floderus, A; Flores Castillo, L R; Flowerdew, M J; Fokitis, M; Fonseca Martin, T; Forbush, D A; Formica, A; Forti, A; Fortin, D; Foster, J M; Fournier, D; Foussat, A; Fowler, A J; Fowler, K; Fox, H; Francavilla, P; Franchino, S; Francis, D; Frank, T; Franklin, M; Franz, S; Fraternali, M; Fratina, S; French, S T; Friedrich, F; Froeschl, R; Froidevaux, D; Frost, J A; Fukunaga, C; Fullana Torregrosa, E; Fuster, J; Gabaldon, C; Gabizon, O; Gadfort, T; Gadomski, S; Gagliardi, G; Gagnon, P; Galea, C; Gallas, E J; Gallo, V; Gallop, B J; Gallus, P; Gan, K K; Gao, Y S; Gapienko, V A; Gaponenko, A; Garberson, F; Garcia-Sciveres, M; García, C; García Navarro, J E; Gardner, R W; Garelli, N; Garitaonandia, H; Garonne, V; Garvey, J; Gatti, C; Gaudio, G; Gaur, B; Gauthier, L; Gauzzi, P; Gavrilenko, I L; Gay, C; Gaycken, G; Gayde, J-C; Gazis, E N; Ge, P; Gee, C N P; Geerts, D A A; Geich-Gimbel, Ch; Gellerstedt, K; Gemme, C; Gemmell, A; Genest, M H; Gentile, S; George, M; George, S; Gerlach, P; Gershon, A; Geweniger, C; Ghazlane, H; Ghodbane, N; Giacobbe, B; Giagu, S; Giakoumopoulou, V; Giangiobbe, V; Gianotti, F; Gibbard, B; Gibson, A; Gibson, S M; Gilbert, L M; Gilewsky, V; Gillberg, D; Gillman, A R; Gingrich, D M; Ginzburg, J; Giokaris, N; Giordani, M P; Giordano, R; Giorgi, F M; Giovannini, P; Giraud, P F; Giugni, D; Giunta, M; Giusti, P; Gjelsten, B K; Gladilin, L K; Glasman, C; Glatzer, J; Glazov, A; Glitza, K W; Glonti, G L; Goddard, J R; Godfrey, J; Godlewski, J; Goebel, M; Göpfert, T; Goeringer, C; Gössling, C; Göttfert, T; Goldfarb, S; Golling, T; Gomes, A; Gomez Fajardo, L S; Gonçalo, R; Goncalves Pinto Firmino Da Costa, J; Gonella, L; Gonidec, A; Gonzalez, S; González de la Hoz, S; Gonzalez Parra, G; Gonzalez Silva, M L; Gonzalez-Sevilla, S; Goodson, J J; Goossens, L; Gorbounov, P A; Gordon, H A; Gorelov, I; Gorfine, G; Gorini, B; Gorini, E; Gorišek, A; Gornicki, E; Gorokhov, S A; Goryachev, V N; Gosdzik, B; Gosselink, M; Gostkin, M I; Gough Eschrich, I; Gouighri, M; Goujdami, D; Goulette, M P; Goussiou, A G; Goy, C; Gozpinar, S; Grabowska-Bold, I; Grafström, P; Grahn, K-J; Grancagnolo, F; Grancagnolo, S; Grassi, V; Gratchev, V; Grau, N; Gray, H M; Gray, J A; Graziani, E; Grebenyuk, O G; Greenshaw, T; Greenwood, Z D; Gregersen, K; Gregor, I M; Grenier, P; Griffiths, J; Grigalashvili, N; Grillo, A A; Grinstein, S; Grishkevich, Y V; Grivaz, J-F; Groh, M; Gross, E; Grosse-Knetter, J; Groth-Jensen, J; Grybel, K; Guarino, V J; Guest, D; Guicheney, C; Guida, A; Guindon, S; Guler, H; Gunther, J; Guo, B; Guo, J; Gupta, A; Gusakov, Y; Gushchin, V N; Gutierrez, P; Guttman, N; Gutzwiller, O; Guyot, C; Gwenlan, C; Gwilliam, C B; Haas, A; Haas, S; Haber, C; Hackenburg, R; Hadavand, H K; Hadley, D R; Haefner, P; Hahn, F; Haider, S; Hajduk, Z; Hakobyan, H; Hall, D; Haller, J; Hamacher, K; Hamal, P; Hamer, M; Hamilton, A; Hamilton, S; Han, H; Han, L; Hanagaki, K; Hanawa, K; Hance, M; Handel, C; Hanke, P; Hansen, J R; Hansen, J B; Hansen, J D; Hansen, P H; Hansson, P; Hara, K; Hare, G A; Harenberg, T; Harkusha, S; Harper, D; Harrington, R D; Harris, O M; Harrison, K; Hartert, J; Hartjes, F; Haruyama, T; Harvey, A; Hasegawa, S; Hasegawa, Y; Hassani, S; Hatch, M; Hauff, D; Haug, S; Hauschild, M; Hauser, R; Havranek, M; Hawes, B M; Hawkes, C M; Hawkings, R J; Hawkins, A D; Hawkins, D; Hayakawa, T; Hayashi, T; Hayden, D; Hayward, H S; Haywood, S J; Hazen, E; He, M; Head, S J; Hedberg, V; Heelan, L; Heim, S; Heinemann, B; Heisterkamp, S; Helary, L; Heller, C; Heller, M; Hellman, S; Hellmich, D; Helsens, C; Henderson, R C W; Henke, M; Henrichs, A; Henriques Correia, A M; Henrot-Versille, S; Henry-Couannier, F; Hensel, C; Henß, T; Hernandez, C M; Hernández Jiménez, Y; Herrberg, R; Hershenhorn, A D; Herten, G; Hertenberger, R; Hervas, L; Hesketh, G G; Hessey, N P; Higón-Rodriguez, E; Hill, D; Hill, J C; Hill, N; Hiller, K H; Hillert, S; Hillier, S J; Hinchliffe, I; Hines, E; Hirose, M; Hirsch, F; Hirschbuehl, D; Hobbs, J; Hod, N; Hodgkinson, M C; Hodgson, P; Hoecker, A; Hoeferkamp, M R; Hoffman, J; Hoffmann, D; Hohlfeld, M; Holder, M; Holmgren, S O; Holy, T; Holzbauer, J L; Homma, Y; Hong, T M; Hooft van Huysduynen, L; Horazdovsky, T; Horn, C; Horner, S; Hostachy, J-Y; Hou, S; Houlden, M A; Hoummada, A; Howarth, J; Howell, D F; Hristova, I; Hrivnac, J; Hruska, I; Hryn'ova, T; Hsu, P J; Hsu, S-C; Huang, G S; Hubacek, Z; Hubaut, F; Huegging, F; Huettmann, A; Huffman, T B; Hughes, E W; Hughes, G; Hughes-Jones, R E; Huhtinen, M; Hurst, P; Hurwitz, M; Husemann, U; Huseynov, N; Huston, J; Huth, J; Iacobucci, G; Iakovidis, G; Ibbotson, M; Ibragimov, I; Ichimiya, R; Iconomidou-Fayard, L; Idarraga, J; Iengo, P; Igonkina, O; Ikegami, Y; Ikeno, M; Ilchenko, Y; Iliadis, D; Ilic, N; Imori, M; Ince, T; Inigo-Golfin, J; Ioannou, P; Iodice, M; Ippolito, V; Irles Quiles, A; Isaksson, C; Ishikawa, A; Ishino, M; Ishmukhametov, R; Issever, C; Istin, S; Ivashin, A V; Iwanski, W; Iwasaki, H; Izen, J M; Izzo, V; Jackson, B; Jackson, J N; Jackson, P; Jaekel, M R; Jain, V; Jakobs, K; Jakobsen, S; Jakubek, J; Jana, D K; Jankowski, E; Jansen, E; Jansen, H; Jantsch, A; Janus, M; Jarlskog, G; Jeanty, L; Jelen, K; Jen-La Plante, I; Jenni, P; Jeremie, A; Jež, P; Jézéquel, S; Jha, M K; Ji, H; Ji, W; Jia, J; Jiang, Y; Jimenez Belenguer, M; Jin, G; Jin, S; Jinnouchi, O; Joergensen, M D; Joffe, D; Johansen, L G; Johansen, M; Johansson, K E; Johansson, P; Johnert, S; Johns, K A; Jon-And, K; Jones, G; Jones, R W L; Jones, T W; Jones, T J; Jonsson, O; Joram, C; Jorge, P M; Joseph, J; Jovicevic, J; Jovin, T; Ju, X; Jung, C A; Jungst, R M; Juranek, V; Jussel, P; Juste Rozas, A; Kabachenko, V V; Kabana, S; Kaci, M; Kaczmarska, A; Kadlecik, P; Kado, M; Kagan, H; Kagan, M; Kaiser, S; Kajomovitz, E; Kalinin, S; Kalinovskaya, L V; Kama, S; Kanaya, N; Kaneda, M; Kaneti, S; Kanno, T; Kantserov, V A; Kanzaki, J; Kaplan, B; Kapliy, A; Kaplon, J; Kar, D; Karagoz, M; Karnevskiy, M; Karr, K; Kartvelishvili, V; Karyukhin, A N; Kashif, L; Kasieczka, G; Kasmi, A; Kass, R D; Kastanas, A; Kataoka, M; Kataoka, Y; Katsoufis, E; Katzy, J; Kaushik, V; Kawagoe, K; Kawamoto, T; Kawamura, G; Kayl, M S; Kazanin, V A; Kazarinov, M Y; Keeler, R; Kehoe, R; Keil, M; Kekelidze, G D; Keller, J S; Kennedy, J; Kenyon, M; Kepka, O; Kerschen, N; Kerševan, B P; Kersten, S; Kessoku, K; Keung, J; Khakzad, M; Khalil-Zada, F; Khandanyan, H; Khanov, A; Kharchenko, D; Khodinov, A; Kholodenko, A G; Khomich, A; Khoo, T J; Khoriauli, G; Khoroshilov, A; Khovanskiy, N; Khovanskiy, V; Khramov, E; Khubua, J; Kim, H; Kim, M S; Kim, S H; Kimura, N; Kind, O; King, B T; King, M; King, R S B; Kirk, J; Kirsch, L E; Kiryunin, A E; Kishimoto, T; Kisielewska, D; Kittelmann, T; Kiver, A M; Kladiva, E; Klaiber-Lodewigs, J; Klein, M; Klein, U; Kleinknecht, K; Klemetti, M; Klier, A; Klimek, P; Klimentov, A; Klingenberg, R; Klinger, J A; Klinkby, E B; Klioutchnikova, T; Klok, P F; Klous, S; Kluge, E-E; Kluge, T; Kluit, P; Kluth, S; Knecht, N S; Kneringer, E; Knobloch, J; Knoops, E B F G; Knue, A; Ko, B R; Kobayashi, T; Kobel, M; Kocian, M; Kodys, P; Köneke, K; König, A C; Koenig, S; Köpke, L; Koetsveld, F; Koevesarki, P; Koffas, T; Koffeman, E; Kogan, L A; Kohn, F; Kohout, Z; Kohriki, T; Koi, T; Kokott, T; Kolachev, G M; Kolanoski, H; Kolesnikov, V; Koletsou, I; Koll, J; Kollefrath, M; Kolya, S D; Komar, A A; Komori, Y; Kondo, T; Kono, T; Kononov, A I; Konoplich, R; Konstantinidis, N; Kootz, A; Koperny, S; Korcyl, K; Kordas, K; Koreshev, V; Korn, A; Korol, A; Korolkov, I; Korolkova, E V; Korotkov, V A; Kortner, O; Kortner, S; Kostyukhin, V V; Kotamäki, M J; Kotov, S; Kotov, V M; Kotwal, A; Kourkoumelis, C; Kouskoura, V; Koutsman, A; Kowalewski, R; Kowalski, T Z; Kozanecki, W; Kozhin, A S; Kral, V; Kramarenko, V A; Kramberger, G; Krasny, M W; Krasznahorkay, A; Kraus, J; Kraus, J K; Kreisel, A; Krejci, F; Kretzschmar, J; Krieger, N; Krieger, P; Kroeninger, K; Kroha, H; Kroll, J; Kroseberg, J; Krstic, J; Kruchonak, U; Krüger, H; Kruker, T; Krumnack, N; Krumshteyn, Z V; Kruth, A; Kubota, T; Kuday, S; Kuehn, S; Kugel, A; Kuhl, T; Kuhn, D; Kukhtin, V; Kulchitsky, Y; Kuleshov, S; Kummer, C; Kuna, M; Kundu, N; Kunkle, J; Kupco, A; Kurashige, H; Kurata, M; Kurochkin, Y A; Kus, V; Kuwertz, E S; Kuze, M; Kvita, J; Kwee, R; La Rosa, A; La Rotonda, L; Labarga, L; Labbe, J; Lablak, S; Lacasta, C; Lacava, F; Lacker, H; Lacour, D; Lacuesta, V R; Ladygin, E; Lafaye, R; Laforge, B; Lagouri, T; Lai, S; Laisne, E; Lamanna, M; Lambourne, L; Lampen, C L; Lampl, W; Lancon, E; Landgraf, U; Landon, M P J; Lane, J L; Lange, C; Lankford, A J; Lanni, F; Lantzsch, K; Laplace, S; Lapoire, C; Laporte, J F; Lari, T; Larionov, A V; Larner, A; Lasseur, C; Lassnig, M; Laurelli, P; Lavorini, V; Lavrijsen, W; Laycock, P; Lazarev, A B; Le Dortz, O; Le Guirriec, E; Le Maner, C; Le Menedeu, E; Lebel, C; LeCompte, T; Ledroit-Guillon, F; Lee, H; Lee, J S H; Lee, S C; Lee, L; Lefebvre, M; Legendre, M; Leger, A; LeGeyt, B C; Legger, F; Leggett, C; Lehmacher, M; Lehmann Miotto, G; Lei, X; Leite, M A L; Leitner, R; Lellouch, D; Leltchouk, M; Lemmer, B; Lendermann, V; Leney, K J C; Lenz, T; Lenzen, G; Lenzi, B; Leonhardt, K; Leontsinis, S; Leroy, C; Lessard, J-R; Lesser, J; Lester, C G; Leung Fook Cheong, A; Levêque, J; Levin, D; Levinson, L J; Levitski, M S; Lewis, A; Lewis, G H; Leyko, A M; Leyton, M; Li, B; Li, H; Li, S; Li, X; Liang, Z; Liao, H; Liberti, B; Lichard, P; Lichtnecker, M; Lie, K; Liebig, W; Lifshitz, R; Lilley, J N; Limbach, C; Limosani, A; Limper, M; Lin, S C; Linde, F; Linnemann, J T; Lipeles, E; Lipinsky, L; Lipniacka, A; Liss, T M; Lissauer, D; Lister, A; Litke, A M; Liu, C; Liu, D; Liu, H; Liu, J B; Liu, M; Liu, Y; Livan, M; Livermore, S S A; Lleres, A; Llorente Merino, J; Lloyd, S L; Lobodzinska, E; Loch, P; Lockman, W S; Loddenkoetter, T; Loebinger, F K; Loginov, A; Loh, C W; Lohse, T; Lohwasser, K; Lokajicek, M; Loken, J; Lombardo, V P; Long, R E; Lopes, L; Lopez Mateos, D; Lorenz, J; Lorenzo Martinez, N; Losada, M; Loscutoff, P; Lo Sterzo, F; Losty, M J; Lou, X; Lounis, A; Loureiro, K F; Love, J; Love, P A; Lowe, A J; Lu, F; Lubatti, H J; Luci, C; Lucotte, A; Ludwig, A; Ludwig, D; Ludwig, I; Ludwig, J; Luehring, F; Luijckx, G; Lukas, W; Lumb, D; Luminari, L; Lund, E; Lund-Jensen, B; Lundberg, B; Lundberg, J; Lundquist, J; Lungwitz, M; Lutz, G; Lynn, D; Lys, J; Lytken, E; Ma, H; Ma, L L; Macana Goia, J A; Maccarrone, G; Macchiolo, A; Maček, B; Machado Miguens, J; Mackeprang, R; Madaras, R J; Mader, W F; Maenner, R; Maeno, T; Mättig, P; Mättig, S; Magnoni, L; Magradze, E; Mahalalel, Y; Mahboubi, K; Mahmoud, S; Mahout, G; Maiani, C; Maidantchik, C; Maio, A; Majewski, S; Makida, Y; Makovec, N; Mal, P; Malaescu, B; Malecki, Pa; Malecki, P; Maleev, V P; Malek, F; Mallik, U; Malon, D; Malone, C; Maltezos, S; Malyshev, V; Malyukov, S; Mameghani, R; Mamuzic, J; Manabe, A; Mandelli, L; Mandić, I; Mandrysch, R; Maneira, J; Mangeard, P S; Manhaes de Andrade Filho, L; Manjavidze, I D; Mann, A; Manning, P M; Manousakis-Katsikakis, A; Mansoulie, B; Manz, A; Mapelli, A; Mapelli, L; March, L; Marchand, J F; Marchese, F; Marchiori, G; Marcisovsky, M; Marino, C P; Marroquim, F; Marshall, R; Marshall, Z; Martens, F K; Marti-Garcia, S; Martin, A J; Martin, B; Martin, B; Martin, F F; Martin, J P; Martin, Ph; Martin, T A; Martin, V J; Martin dit Latour, B; Martin-Haugh, S; Martinez, M; Martinez Outschoorn, V; Martyniuk, A C; Marx, M; Marzano, F; Marzin, A; Masetti, L; Mashimo, T; Mashinistov, R; Masik, J; Maslennikov, A L; Massa, I; Massaro, G; Massol, N; Mastrandrea, P; Mastroberardino, A; Masubuchi, T; Matricon, P; Matsumoto, H; Matsunaga, H; Matsushita, T; Mattravers, C; Maugain, J M; Maurer, J; Maxfield, S J; Maximov, D A; May, E N; Mayne, A; Mazini, R; Mazur, M; Mazzanti, M; Mc Kee, S P; McCarn, A; McCarthy, R L; McCarthy, T G; McCubbin, N A; McFarlane, K W; Mcfayden, J A; McGlone, H; Mchedlidze, G; McLaren, R A; Mclaughlan, T; McMahon, S J; McPherson, R A; Meade, A; Mechnich, J; Mechtel, M; Medinnis, M; Meera-Lebbai, R; Meguro, T; Mehdiyev, R; Mehlhase, S; Mehta, A; Meier, K; Meirose, B; Melachrinos, C; Mellado Garcia, B R; Mendoza Navas, L; Meng, Z; Mengarelli, A; Menke, S; Menot, C; Meoni, E; Mercurio, K M; Mermod, P; Merola, L; Meroni, C; Merritt, F S; Merritt, H; Messina, A; Metcalfe, J; Mete, A S; Meyer, C; Meyer, C; Meyer, J-P; Meyer, J; Meyer, J; Meyer, T C; Meyer, W T; Miao, J; Michal, S; Micu, L; Middleton, R P; Migas, S; Mijović, L; Mikenberg, G; Mikestikova, M; Mikuž, M; Miller, D W; Miller, R J; Mills, W J; Mills, C; Milov, A; Milstead, D A; Milstein, D; Minaenko, A A; Miñano Moya, M; Minashvili, I A; Mincer, A I; Mindur, B; Mineev, M; Ming, Y; Mir, L M; Mirabelli, G; Miralles Verge, L; Misiejuk, A; Mitrevski, J; Mitrofanov, G Y; Mitsou, V A; Mitsui, S; Miyagawa, P S; Miyazaki, K; Mjörnmark, J U; Moa, T; Mockett, P; Moed, S; Moeller, V; Mönig, K; Möser, N; Mohapatra, S; Mohr, W; Mohrdieck-Möck, S; Moisseev, A M; Moles-Valls, R; Molina-Perez, J; Monk, J; Monnier, E; Montesano, S; Monticelli, F; Monzani, S; Moore, R W; Moorhead, G F; Mora Herrera, C; Moraes, A; Morange, N; Morel, J; Morello, G; Moreno, D; Moreno Llácer, M; Morettini, P; Morgenstern, M; Morii, M; Morin, J; Morley, A K; Mornacchi, G; Morozov, S V; Morris, J D; Morvaj, L; Moser, H G; Mosidze, M; Moss, J; Mount, R; Mountricha, E; Mouraviev, S V; Moyse, E J W; Mudrinic, M; Mueller, F; Mueller, J; Mueller, K; Müller, T A; Mueller, T; Muenstermann, D; Muir, A; Munwes, Y; Murray, W J; Mussche, I; Musto, E; Myagkov, A G; Nadal, J; Nagai, K; Nagano, K; Nagarkar, A; Nagasaka, Y; Nagel, M; Nairz, A M; Nakahama, Y; Nakamura, K; Nakamura, T; Nakano, I; Nanava, G; Napier, A; Narayan, R; Nash, M; Nation, N R; Nattermann, T; Naumann, T; Navarro, G; Neal, H A; Nebot, E; Nechaeva, P Yu; Neep, T J; Negri, A; Negri, G; Nektarijevic, S; Nelson, A; Nelson, T K; Nemecek, S; Nemethy, P; Nepomuceno, A A; Nessi, M; Neubauer, M S; Neusiedl, A; Neves, R M; Nevski, P; Newman, P R; Nguyen Thi Hong, V; Nickerson, R B; Nicolaidou, R; Nicolas, L; Nicquevert, B; Niedercorn, F; Nielsen, J; Niinikoski, T; Nikiforou, N; Nikiforov, A; Nikolaenko, V; Nikolaev, K; Nikolic-Audit, I; Nikolics, K; Nikolopoulos, K; Nilsen, H; Nilsson, P; Ninomiya, Y; Nisati, A; Nishiyama, T; Nisius, R; Nodulman, L; Nomachi, M; Nomidis, I; Nordberg, M; Nordkvist, B; Norton, P R; Novakova, J; Nozaki, M; Nozka, L; Nugent, I M; Nuncio-Quiroz, A-E; Nunes Hanninger, G; Nunnemann, T; Nurse, E; O'Brien, B J; O'Neale, S W; O'Neil, D C; O'Shea, V; Oakes, L B; Oakham, F G; Oberlack, H; Ocariz, J; Ochi, A; Oda, S; Odaka, S; Odier, J; Ogren, H; Oh, A; Oh, S H; Ohm, C C; Ohshima, T; Ohshita, H; Okada, S; Okawa, H; Okumura, Y; Okuyama, T; Olariu, A; Olcese, M; Olchevski, A G; Olivares Pino, S A; Oliveira, M; Oliveira Damazio, D; Oliver Garcia, E; Olivito, D; Olszewski, A; Olszowska, J; Omachi, C; Onofre, A; Onyisi, P U E; Oram, C J; Oreglia, M J; Oren, Y; Orestano, D; Orlando, N; Orlov, I; Oropeza Barrera, C; Orr, R S; Osculati, B; Ospanov, R; Osuna, C; Otero Y Garzon, G; Ottersbach, J P; Ouchrif, M; Ouellette, E A; Ould-Saada, F; Ouraou, A; Ouyang, Q; Ovcharova, A; Owen, M; Owen, S; Ozcan, V E; Ozturk, N; Pacheco Pages, A; Padilla Aranda, C; Pagan Griso, S; Paganis, E; Paige, F; Pais, P; Pajchel, K; Palacino, G; Paleari, C P; Palestini, S; Pallin, D; Palma, A; Palmer, J D; Pan, Y B; Panagiotopoulou, E; Panes, B; Panikashvili, N; Panitkin, S; Pantea, D; Panuskova, M; Paolone, V; Papadelis, A; Papadopoulou, Th D; Paramonov, A; Park, W; Parker, M A; Parodi, F; Parsons, J A; Parzefall, U; Pashapour, S; Pasqualucci, E; Passaggio, S; Passeri, A; Pastore, F; Pastore, Fr; Pásztor, G; Pataraia, S; Patel, N; Pater, J R; Patricelli, S; Pauly, T; Pecsy, M; Pedraza Morales, M I; Peleganchuk, S V; Peng, H; Pengo, R; Penning, B; Penson, A; Penwell, J; Perantoni, M; Perez, K; Perez Cavalcanti, T; Perez Codina, E; Pérez García-Estañ, M T; Perez Reale, V; Perini, L; Pernegger, H; Perrino, R; Perrodo, P; Persembe, S; Peshekhonov, V D; Peters, K; Petersen, B A; Petersen, J; Petersen, T C; Petit, E; Petridis, A; Petridou, C; Petrolo, E; Petrucci, F; Petschull, D; Petteni, M; Pezoa, R; Phan, A; Phillips, P W; Piacquadio, G; Picazio, A; Piccaro, E; Piccinini, M; Piec, S M; Piegaia, R; Pignotti, D T; Pilcher, J E; Pilkington, A D; Pina, J; Pinamonti, M; Pinder, A; Pinfold, J L; Ping, J; Pinto, B; Pirotte, O; Pizio, C; Placakyte, R; Plamondon, M; Pleier, M-A; Pleskach, A V; Plotnikova, E; Poblaguev, A; Poddar, S; Podlyski, F; Poggioli, L; Poghosyan, T; Pohl, M; Polci, F; Polesello, G; Policicchio, A; Polini, A; Poll, J; Polychronakos, V; Pomarede, D M; Pomeroy, D; Pommès, K; Pontecorvo, L; Pope, B G; Popeneciu, G A; Popovic, D S; Poppleton, A; Portell Bueso, X; Posch, C; Pospelov, G E; Pospisil, S; Potrap, I N; Potter, C J; Potter, C T; Poulard, G; Poveda, J; Pozdnyakov, V; Prabhu, R; Pralavorio, P; Pranko, A; Prasad, S; Pravahan, R; Prell, S; Pretzl, K; Pribyl, L; Price, D; Price, J; Price, L E; Price, M J; Prieur, D; Primavera, M; Prokofiev, K; Prokoshin, F; Protopopescu, S; Proudfoot, J; Prudent, X; Przybycien, M; Przysiezniak, H; Psoroulas, S; Ptacek, E; Pueschel, E; Purdham, J; Purohit, M; Puzo, P; Pylypchenko, Y; Qian, J; Qian, Z; Qin, Z; Quadt, A; Quarrie, D R; Quayle, W B; Quinonez, F; Raas, M; Radescu, V; Radics, B; Radloff, P; Rador, T; Ragusa, F; Rahal, G; Rahimi, A M; Rahm, D; Rajagopalan, S; Rammensee, M; Rammes, M; Randle-Conde, A S; Randrianarivony, K; Ratoff, P N; Rauscher, F; Rave, T C; Raymond, M; Read, A L; Rebuzzi, D M; Redelbach, A; Redlinger, G; Reece, R; Reeves, K; Reichold, A; Reinherz-Aronis, E; Reinsch, A; Reisinger, I; Rembser, C; Ren, Z L; Renaud, A; Rescigno, M; Resconi, S; Resende, B; Reznicek, P; Rezvani, R; Richards, A; Richter, R; Richter-Was, E; Ridel, M; Rijpstra, M; Rijssenbeek, M; Rimoldi, A; Rinaldi, L; Rios, R R; Riu, I; Rivoltella, G; Rizatdinova, F; Rizvi, E; Robertson, S H; Robichaud-Veronneau, A; Robinson, D; Robinson, J E M; Robson, A; Rocha de Lima, J G; Roda, C; Roda Dos Santos, D; Rodriguez, D; Roe, A; Roe, S; Røhne, O; Rojo, V; Rolli, S; Romaniouk, A; Romano, M; Romanov, V M; Romeo, G; Romero Adam, E; Roos, L; Ros, E; Rosati, S; Rosbach, K; Rose, A; Rose, M; Rosenbaum, G A; Rosenberg, E I; Rosendahl, P L; Rosenthal, O; Rosselet, L; Rossetti, V; Rossi, E; Rossi, L P; Rotaru, M; Roth, I; Rothberg, J; Rousseau, D; Royon, C R; Rozanov, A; Rozen, Y; Ruan, X; Rubinskiy, I; Ruckert, B; Ruckstuhl, N; Rud, V I; Rudolph, C; Rudolph, G; Rühr, F; Ruggieri, F; Ruiz-Martinez, A; Rumiantsev, V; Rumyantsev, L; Runge, K; Rurikova, Z; Rusakovich, N A; Rutherfoord, J P; Ruwiedel, C; Ruzicka, P; Ryabov, Y F; Ryadovikov, V; Ryan, P; Rybar, M; Rybkin, G; Ryder, N C; Rzaeva, S; Saavedra, A F; Sadeh, I; Sadrozinski, H F-W; Sadykov, R; Safai Tehrani, F; Sakamoto, H; Salamanna, G; Salamon, A; Saleem, M; Salihagic, D; Salnikov, A; Salt, J; Salvachua Ferrando, B M; Salvatore, D; Salvatore, F; Salvucci, A; Salzburger, A; Sampsonidis, D; Samset, B H; Sanchez, A; Sanchez Martinez, V; Sandaker, H; Sander, H G; Sanders, M P; Sandhoff, M; Sandoval, T; Sandoval, C; Sandstroem, R; Sandvoss, S; Sankey, D P C; Sansoni, A; Santamarina Rios, C; Santoni, C; Santonico, R; Santos, H; Saraiva, J G; Sarangi, T; Sarkisyan-Grinbaum, E; Sarri, F; Sartisohn, G; Sasaki, O; Sasaki, T; Sasao, N; Satsounkevitch, I; Sauvage, G; Sauvan, E; Sauvan, J B; Savard, P; Savinov, V; Savu, D O; Sawyer, L; Saxon, D H; Saxon, J; Says, L P; Sbarra, C; Sbrizzi, A; Scallon, O; Scannicchio, D A; Scarcella, M; Schaarschmidt, J; Schacht, P; Schaefer, D; Schäfer, U; Schaepe, S; Schaetzel, S; Schaffer, A C; Schaile, D; Schamberger, R D; Schamov, A G; Scharf, V; Schegelsky, V A; Scheirich, D; Schernau, M; Scherzer, M I; Schiavi, C; Schieck, J; Schioppa, M; Schlenker, S; Schlereth, J L; Schmidt, E; Schmieden, K; Schmitt, C; Schmitt, S; Schmitz, M; Schöning, A; Schott, M; Schouten, D; Schovancova, J; Schram, M; Schroeder, C; Schroer, N; Schuler, G; Schultens, M J; Schultes, J; Schultz-Coulon, H-C; Schulz, H; Schumacher, J W; Schumacher, M; Schumm, B A; Schune, Ph; Schwartzman, A; Schwemling, Ph; Schwienhorst, R; Schwierz, R; Schwindling, J; Schwindt, T; Schwoerer, M; Scifo, E; Sciolla, G; Scott, W G; Searcy, J; Sedov, G; Sedykh, E; Segura, E; Seidel, S C; Seiden, A; Seifert, F; Seixas, J M; Sekhniaidze, G; Sekula, S J; Selbach, K E; Seliverstov, D M; Sellden, B; Sellers, G; Seman, M; Semprini-Cesari, N; Serfon, C; Serin, L; Serkin, L; Seuster, R; Severini, H; Sevior, M E; Sfyrla, A; Shabalina, E; Shamim, M; Shan, L Y; Shank, J T; Shao, Q T; Shapiro, M; Shatalov, P B; Shaver, L; Shaw, K; Sherman, D; Sherwood, P; Shibata, A; Shichi, H; Shimizu, S; Shimojima, M; Shin, T; Shiyakova, M; Shmeleva, A; Shochet, M J; Short, D; Shrestha, S; Shulga, E; Shupe, M A; Sicho, P; Sidoti, A; Siegert, F; Sijacki, Dj; Silbert, O; Silva, J; Silver, Y; Silverstein, D; Silverstein, S B; Simak, V; Simard, O; Simic, Lj; Simion, S; Simmons, B; Simoniello, R; Simonyan, M; Sinervo, P; Sinev, N B; Sipica, V; Siragusa, G; Sircar, A; Sisakyan, A N; Sivoklokov, S Yu; Sjölin, J; Sjursen, T B; Skinnari, L A; Skottowe, H P; Skovpen, K; Skubic, P; Skvorodnev, N; Slater, M; Slavicek, T; Sliwa, K; Sloper, J; Smakhtin, V; Smart, B H; Smirnov, S Yu; Smirnov, Y; Smirnova, L N; Smirnova, O; Smith, B C; Smith, D; Smith, K M; Smizanska, M; Smolek, K; Snesarev, A A; Snow, S W; Snow, J; Snuverink, J; Snyder, S; Soares, M; Sobie, R; Sodomka, J; Soffer, A; Solans, C A; Solar, M; Solc, J; Soldatov, E; Soldevila, U; Solfaroli Camillocci, E; Solodkov, A A; Solovyanov, O V; Soni, N; Sopko, V; Sopko, B; Sosebee, M; Soualah, R; Soukharev, A; Spagnolo, S; Spanò, F; Spighi, R; Spigo, G; Spila, F; Spiwoks, R; Spousta, M; Spreitzer, T; Spurlock, B; St Denis, R D; Stahlman, J; Stamen, R; Stanecka, E; Stanek, R W; Stanescu, C; Stanescu-Bellu, M; Stapnes, S; Starchenko, E A; Stark, J; Staroba, P; Starovoitov, P; Staude, A; Stavina, P; Steele, G; Steinbach, P; Steinberg, P; Stekl, I; Stelzer, B; Stelzer, H J; Stelzer-Chilton, O; Stenzel, H; Stern, S; Stevenson, K; Stewart, G A; Stillings, J A; Stockton, M C; Stoerig, K; Stoicea, G; Stonjek, S; Strachota, P; Stradling, A R; Straessner, A; Strandberg, J; Strandberg, S; Strandlie, A; Strang, M; Strauss, E; Strauss, M; Strizenec, P; Ströhmer, R; Strom, D M; Strong, J A; Stroynowski, R; Strube, J; Stugu, B; Stumer, I; Stupak, J; Sturm, P; Styles, N A; Soh, D A; Su, D; Subramania, Hs; Succurro, A; Sugaya, Y; Sugimoto, T; Suhr, C; Suita, K; Suk, M; Sulin, V V; Sultansoy, S; Sumida, T; Sun, X; Sundermann, J E; Suruliz, K; Sushkov, S; Susinno, G; Sutton, M R; Suzuki, Y; Suzuki, Y; Svatos, M; Sviridov, Yu M; Swedish, S; Sykora, I; Sykora, T; Szeless, B; Sánchez, J; Ta, D; Tackmann, K; Taffard, A; Tafirout, R; Taiblum, N; Takahashi, Y; Takai, H; Takashima, R; Takeda, H; Takeshita, T; Takubo, Y; Talby, M; Talyshev, A; Tamsett, M C; Tanaka, J; Tanaka, R; Tanaka, S; Tanaka, S; Tanaka, Y; Tanasijczuk, A J; Tani, K; Tannoury, N; Tappern, G P; Tapprogge, S; Tardif, D; Tarem, S; Tarrade, F; Tartarelli, G F; Tas, P; Tasevsky, M; Tassi, E; Tatarkhanov, M; Tayalati, Y; Taylor, C; Taylor, F E; Taylor, G N; Taylor, W; Teinturier, M; Teixeira Dias Castanheira, M; Teixeira-Dias, P; Temming, K K; Ten Kate, H; Teng, P K; Terada, S; Terashi, K; Terron, J; Testa, M; Teuscher, R J; Thadome, J; Therhaag, J; Theveneaux-Pelzer, T; Thioye, M; Thoma, S; Thomas, J P; Thompson, E N; Thompson, P D; Thompson, P D; Thompson, A S; Thomsen, L A; Thomson, E; Thomson, M; Thun, R P; Tian, F; Tibbetts, M J; Tic, T; Tikhomirov, V O; Tikhonov, Y A; Timoshenko, S; Tipton, P; Tique Aires Viegas, F J; Tisserant, S; Tobias, J; Toczek, B; Todorov, T; Todorova-Nova, S; Toggerson, B; Tojo, J; Tokár, S; Tokunaga, K; Tokushuku, K; Tollefson, K; Tomoto, M; Tompkins, L; Toms, K; Tong, G; Tonoyan, A; Topfel, C; Topilin, N D; Torchiani, I; Torrence, E; Torres, H; Torró Pastor, E; Toth, J; Touchard, F; Tovey, D R; Trefzger, T; Tremblet, L; Tricoli, A; Trigger, I M; Trincaz-Duvoid, S; Trinh, T N; Tripiana, M F; Trischuk, W; Trivedi, A; Trocmé, B; Troncon, C; Trottier-McDonald, M; Trzebinski, M; Trzupek, A; Tsarouchas, C; Tseng, J C-L; Tsiakiris, M; Tsiareshka, P V; Tsionou, D; Tsipolitis, G; Tsiskaridze, V; Tskhadadze, E G; Tsukerman, I I; Tsulaia, V; Tsung, J-W; Tsuno, S; Tsybychev, D; Tua, A; Tudorache, A; Tudorache, V; Tuggle, J M; Turala, M; Turecek, D; Turk Cakir, I; Turlay, E; Turra, R; Tuts, P M; Tykhonov, A; Tylmad, M; Tyndel, M; Tzanakos, G; Uchida, K; Ueda, I; Ueno, R; Ugland, M; Uhlenbrock, M; Uhrmacher, M; Ukegawa, F; Unal, G; Underwood, D G; Undrus, A; Unel, G; Unno, Y; Urbaniec, D; Usai, G; Uslenghi, M; Vacavant, L; Vacek, V; Vachon, B; Vahsen, S; Valenta, J; Valente, P; Valentinetti, S; Valkar, S; Valladolid Gallego, E; Vallecorsa, S; Valls Ferrer, J A; van der Graaf, H; van der Kraaij, E; Van Der Leeuw, R; van der Poel, E; van der Ster, D; van Eldik, N; van Gemmeren, P; van Kesteren, Z; van Vulpen, I; Vanadia, M; Vandelli, W; Vandoni, G; Vaniachine, A; Vankov, P; Vannucci, F; Varela Rodriguez, F; Vari, R; Varnes, E W; Varol, T; Varouchas, D; Vartapetian, A; Varvell, K E; Vassilakopoulos, V I; Vazeille, F; Vazquez Schroeder, T; Vegni, G; Veillet, J J; Vellidis, C; Veloso, F; Veness, R; Veneziano, S; Ventura, A; Ventura, D; Venturi, M; Venturi, N; Vercesi, V; Verducci, M; Verkerke, W; Vermeulen, J C; Vest, A; Vetterli, M C; Vichou, I; Vickey, T; Vickey Boeriu, O E; Viehhauser, G H A; Viel, S; Villa, M; Villaplana Perez, M; Vilucchi, E; Vincter, M G; Vinek, E; Vinogradov, V B; Virchaux, M; Virzi, J; Vitells, O; Viti, M; Vivarelli, I; Vives Vaque, F; Vlachos, S; Vladoiu, D; Vlasak, M; Vlasov, N; Vogel, A; Vokac, P; Volpi, G; Volpi, M; Volpini, G; von der Schmitt, H; von Loeben, J; von Radziewski, H; von Toerne, E; Vorobel, V; Vorobiev, A P; Vorwerk, V; Vos, M; Voss, R; Voss, T T; Vossebeld, J H; Vranjes, N; Vranjes Milosavljevic, M; Vrba, V; Vreeswijk, M; Vu Anh, T; Vuillermet, R; Vukotic, I; Wagner, W; Wagner, P; Wahlen, H; Wakabayashi, J; Walch, S; Walder, J; Walker, R; Walkowiak, W; Wall, R; Waller, P; Wang, C; Wang, H; Wang, H; Wang, J; Wang, J; Wang, J C; Wang, R; Wang, S M; Warburton, A; Ward, C P; Warsinsky, M; Wasicki, C; Watkins, P M; Watson, A T; Watson, I J; Watson, M F; Watts, G; Watts, S; Waugh, A T; Waugh, B M; Weber, M; Weber, M S; Weber, P; Weidberg, A R; Weigell, P; Weingarten, J; Weiser, C; Wellenstein, H; Wells, P S; Wenaus, T; Wendland, D; Wendler, S; Weng, Z; Wengler, T; Wenig, S; Wermes, N; Werner, M; Werner, P; Werth, M; Wessels, M; Wetter, J; Weydert, C; Whalen, K; Wheeler-Ellis, S J; Whitaker, S P; White, A; White, M J; Whitehead, S R; Whiteson, D; Whittington, D; Wicek, F; Wicke, D; Wickens, F J; Wiedenmann, W; Wielers, M; Wienemann, P; Wiglesworth, C; Wiik, L A M; Wijeratne, P A; Wildauer, A; Wildt, M A; Wilhelm, I; Wilkens, H G; Will, J Z; Williams, E; Williams, H H; Willis, W; Willocq, S; Wilson, J A; Wilson, M G; Wilson, A; Wingerter-Seez, I; Winkelmann, S; Winklmeier, F; Wittgen, M; Wolter, M W; Wolters, H; Wong, W C; Wooden, G; Wosiek, B K; Wotschack, J; Woudstra, M J; Wozniak, K W; Wraight, K; Wright, C; Wright, M; Wrona, B; Wu, S L; Wu, X; Wu, Y; Wulf, E; Wunstorf, R; Wynne, B M; Xella, S; Xiao, M; Xie, S; Xie, Y; Xu, C; Xu, D; Xu, G; Yabsley, B; Yacoob, S; Yamada, M; Yamaguchi, H; Yamamoto, A; Yamamoto, K; Yamamoto, S; Yamamura, T; Yamanaka, T; Yamaoka, J; Yamazaki, T; Yamazaki, Y; Yan, Z; Yang, H; Yang, U K; Yang, Y; Yang, Y; Yang, Z; Yanush, S; Yao, Y; Yasu, Y; Ybeles Smit, G V; Ye, J; Ye, S; Yilmaz, M; Yoosoofmiya, R; Yorita, K; Yoshida, R; Young, C; Youssef, S; Yu, D; Yu, J; Yu, J; Yuan, L; Yurkewicz, A; Zabinski, B; Zaets, V G; Zaidan, R; Zaitsev, A M; Zajacova, Z; Zanello, L; Zaytsev, A; Zeitnitz, C; Zeller, M; Zeman, M; Zemla, A; Zendler, C; Zenin, O; Zeniš, T; Zenonos, Z; Zenz, S; Zerwas, D; Zevi della Porta, G; Zhan, Z; Zhang, D; Zhang, H; Zhang, J; Zhang, X; Zhang, Z; Zhao, L; Zhao, T; Zhao, Z; Zhemchugov, A; Zheng, S; Zhong, J; Zhou, B; Zhou, N; Zhou, Y; Zhu, C G; Zhu, H; Zhu, J; Zhu, Y; Zhuang, X; Zhuravlov, V; Zieminska, D; Zimmermann, R; Zimmermann, S; Zimmermann, S; Ziolkowski, M; Zitoun, R; Zivković, L; Zmouchko, V V; Zobernig, G; Zoccoli, A; Zolnierowski, Y; Zsenei, A; zur Nedden, M; Zutshi, V; Zwalinski, L
2012-03-16
A search for the standard model Higgs boson is performed in the diphoton decay channel. The data used correspond to an integrated luminosity of 4.9 fb(-1) collected with the ATLAS detector at the Large Hadron Collider in proton-proton collisions at a center-of-mass energy of √s=7 TeV. In the diphoton mass range 110-150 GeV, the largest excess with respect to the background-only hypothesis is observed at 126.5 GeV, with a local significance of 2.8 standard deviations. Taking the look-elsewhere effect into account in the range 110-150 GeV, this significance becomes 1.5 standard deviations. The standard model Higgs boson is excluded at 95% confidence level in the mass ranges of 113-115 GeV and 134.5-136 GeV.
Defining wilderness quality: the role of standards in wilderness managementa workshop proceedings.
B. Shelby; G. Stankey; B. Shindler
1992-01-01
Integral to maintaining wilderness quality is the implementation of ecological, social, and management standards. A substantial body of wilderness research management experience exists nationwide as a common-pool resource for professionals with a specialized interest in incorporating standards into planning processes. In a 2-day interactive workshop, wilderness...
Carter, Kris K; Lundgren, Ingrid; Correll, Sarah; Schmalz, Tom; McCarter, Tammie; Stroud, Joshua; Bruesch, Amanda; Hahn, Christine G
2018-05-29
Mycobacterium abscessus, an emerging pathogen in healthcare settings, has rarely been associated with community outbreaks. During February-May 2013, Idaho public health officials and pediatric infectious disease physicians investigated an outbreak of M abscessus skin infections in children whose only common exposure was an indoor wading pool. Healthcare providers and parents reported possible M abscessus cases. We used a standardized questionnaire to interview parents of affected children. Clinical specimens were submitted for mycobacterial examination. We conducted an environmental investigation of the pool. Microbial isolates from clinical and environmental samples were identified by sequencing polymerase chain reaction amplicons and underwent pulsed-field gel electrophoresis. Twelve cases were identified. Specimens from 4 of 7 children grew M abscessus or Mycobacterium abscessus/Mycobacterium chelonae . Ten (83%) of 12 children were female; median age was 3 years (range, 2 to 6 years); and all were immunocompetent. Pool maintenance did not fully comply with Idaho state rules governing pool operation. Mycobacterium abscessus/chelonae was isolated from pool equipment. Pulsed-field gel electrophoresis composite patterns were 87% similar between isolates from the pool ladder and 1 patient, and they were 90% similar between isolates from 2 patients. Environmental remediation included hyperchlorination, scrubbing and disinfection of pool surfaces, draining the pool, and replacement of worn pool materials. Immunocompetent children acquired M abscessus cutaneous infection involving hands and feet after exposure to a wading pool. Environmental remediation and proper pool maintenance likely halted transmission. Medical and public health professionals' collaboration effectively detected and controlled an outbreak caused by an emerging recreational waterborne pathogen.
Yedeme, Kokebe; Legese, Melese Hailu; Gonfa, Almaz; Girma, Somson
2017-01-01
Background: From swimming pools, bathers may acquire many potential pathogens or may be affected by the physicochemical characteristics of water used during bathing. Hence, this study aimed at assessing the physicochemical and microbiological quality of public swimming pools located at different hotels and recreation center in Addis Ababa, Ethiopia. Method: A cross sectional study was carried out from February to May, 2016. Nine hotels and one recreation center which recognized to have public swimming services were included. A total of 60 swimming pool water samples from 10 swimming pools were collected at deeper, shallow and intake point twice on a weekly basis using a 250 ml sterile bottle containing sodium thiosulphate. PH, residual chlorine and temperature of samples were recorded at the time of collection. Sample containing bottles were transported in ice box to microbiological laboratory and analyzed on the same day. Standard cultural and biochemical methods were used for isolation and characterization of the main microbial groups. Total viable count, total coliform count, fecal coliform count and E. coli were determined. Data was analyzed using SPSS Version 20. Results: Average PH and temperature of swimming pool water samples were 7.1 and 29oC respectively. Of all analyzed water samples, 58.4% (n=35/60) of them had PH range of 7.2-7.8, 58.3% (n=35/60) of samples had temperature in the range of 21oC-32oC and 25% (n=15/60) of water samples had residual chlorine in the range of 2-3mg/l. 73.3% (n=44/60) of the samples had a total viable count below 200 MPN/ml and 70% (n-42/60) of the samples had Total Coliform Count values less than 2 MPN/100 ml. Moreover, 66.7% (n=40/60) of the samples had fecal coliform counts falling below 1 MPN /100 ml. E. coli was absent in 70% (n=42/60) of the samples while it was present in 30% (n=18/60) of the samples. Conclusion: PH, residual chlorine and temperature value of majority of the swimming pools’ water samples were within the acceptable limit. Regarding microbial quality, most swimming pools’ water samples complied to the WHO standard. Swimming pools that did not comply to the standard both in physicochemical levels and microbial quality need improvement due to their significant health implication. PMID:28761562
Distributional properties of relative phase in bimanual coordination.
James, Eric; Layne, Charles S; Newell, Karl M
2010-10-01
Studies of bimanual coordination have typically estimated the stability of coordination patterns through the use of the circular standard deviation of relative phase. The interpretation of this statistic depends upon the assumption of a von Mises distribution. The present study tested this assumption by examining the distributional properties of relative phase in three bimanual coordination patterns. There were significant deviations from the von Mises distribution due to differences in the kurtosis of distributions. The kurtosis depended upon the relative phase pattern performed, with leptokurtic distributions occurring in the in-phase and antiphase patterns and platykurtic distributions occurring in the 30° pattern. Thus, the distributional assumptions needed to validly and reliably use the standard deviation are not necessarily present in relative phase data though they are qualitatively consistent with the landscape properties of the intrinsic dynamics.
Non-specific filtering of beta-distributed data.
Wang, Xinhui; Laird, Peter W; Hinoue, Toshinori; Groshen, Susan; Siegmund, Kimberly D
2014-06-19
Non-specific feature selection is a dimension reduction procedure performed prior to cluster analysis of high dimensional molecular data. Not all measured features are expected to show biological variation, so only the most varying are selected for analysis. In DNA methylation studies, DNA methylation is measured as a proportion, bounded between 0 and 1, with variance a function of the mean. Filtering on standard deviation biases the selection of probes to those with mean values near 0.5. We explore the effect this has on clustering, and develop alternate filter methods that utilize a variance stabilizing transformation for Beta distributed data and do not share this bias. We compared results for 11 different non-specific filters on eight Infinium HumanMethylation data sets, selected to span a variety of biological conditions. We found that for data sets having a small fraction of samples showing abnormal methylation of a subset of normally unmethylated CpGs, a characteristic of the CpG island methylator phenotype in cancer, a novel filter statistic that utilized a variance-stabilizing transformation for Beta distributed data outperformed the common filter of using standard deviation of the DNA methylation proportion, or its log-transformed M-value, in its ability to detect the cancer subtype in a cluster analysis. However, the standard deviation filter always performed among the best for distinguishing subgroups of normal tissue. The novel filter and standard deviation filter tended to favour features in different genome contexts; for the same data set, the novel filter always selected more features from CpG island promoters and the standard deviation filter always selected more features from non-CpG island intergenic regions. Interestingly, despite selecting largely non-overlapping sets of features, the two filters did find sample subsets that overlapped for some real data sets. We found two different filter statistics that tended to prioritize features with different characteristics, each performed well for identifying clusters of cancer and non-cancer tissue, and identifying a cancer CpG island hypermethylation phenotype. Since cluster analysis is for discovery, we would suggest trying both filters on any new data sets, evaluating the overlap of features selected and clusters discovered.
A simple method to relate microwave radiances to upper tropospheric humidity
NASA Astrophysics Data System (ADS)
Buehler, S. A.; John, V. O.
2005-01-01
A brightness temperature (BT) transformation method can be applied to microwave data to retrieve Jacobian weighted upper tropospheric relative humidity (UTH) in a broad layer centered roughly between 6 and 8 km altitude. The UTH bias is below 4% RH, and the relative UTH bias below 20%. The UTH standard deviation is between 2 and 6.5% RH in absolute numbers, or between 10 and 27% in relative numbers. The standard deviation is dominated by the regression noise, resulting from vertical structure not accounted for by the simple transformation relation. The UTH standard deviation due to radiometric noise alone has a relative standard deviation of approximately 7% for a radiometric noise level of 1 K. The retrieval performance was shown to be of almost constant quality for all viewing angles and latitudes, except for problems at high latitudes due to surface effects. A validation of AMSU UTH against radiosonde UTH shows reasonable agreement if known systematic differences between AMSU and radiosonde are taken into account. When the method is applied to supersaturation studies, regression noise and radiometric noise could lead to an apparent supersaturation even if there were no supersaturation. For a radiometer noise level of 1 K the drop-off slope of the apparent supersaturation is 0.17% RH-1, for a noise level of 2 K the slope is 0.12% RH-1. The main conclusion from this study is that the BT transformation method is very well suited for microwave data. Its particular strength is in climatological applications where the simplicity and the a priori independence are key advantages.
Braithwaite, Susan S; Umpierrez, Guillermo E; Chase, J Geoffrey
2013-09-01
Group metrics are described to quantify blood glucose (BG) variability of hospitalized patients. The "multiplicative surrogate standard deviation" (MSSD) is the reverse-transformed group mean of the standard deviations (SDs) of the logarithmically transformed BG data set of each patient. The "geometric group mean" (GGM) is the reverse-transformed group mean of the means of the logarithmically transformed BG data set of each patient. Before reverse transformation is performed, the mean of means and mean of SDs each has its own SD, which becomes a multiplicative standard deviation (MSD) after reverse transformation. Statistical predictions and comparisons of parametric or nonparametric tests remain valid after reverse transformation. A subset of a previously published BG data set of 20 critically ill patients from the first 72 h of treatment under the SPRINT protocol was transformed logarithmically. After rank ordering according to the SD of the logarithmically transformed BG data of each patient, the cohort was divided into two equal groups, those having lower or higher variability. For the entire cohort, the GGM was 106 (÷/× 1.07) mg/dl, and MSSD was 1.24 (÷/× 1.07). For the subgroups having lower and higher variability, respectively, the GGM did not differ, 104 (÷/× 1.07) versus 109 (÷/× 1.07) mg/dl, but the MSSD differed, 1.17 (÷/× 1.03) versus 1.31 (÷/× 1.05), p = .00004. By using the MSSD with its MSD, groups can be characterized and compared according to glycemic variability of individual patient members. © 2013 Diabetes Technology Society.
Başkan, Ceyda; Köz, Özlem G; Duman, Rahmi; Gökçe, Sabite E; Yarangümeli, Ahmet A; Kural, Gülcan
2016-12-01
The purpose of this study is to examine the demographics, clinical properties, and the relation between white-on-white standard automated perimetry (SAP), short wavelength automated perimetry (SWAP), and optical coherence tomographic (OCT) parameters of patients with ocular hypertension. Sixty-one eyes of 61 patients diagnosed with ocular hypertension in the Ankara Numune Education and Research Hospital ophthalmology unit between January 2010 and January 2011 were included in this study. All patients underwent SAP and SWAP tests with the Humphrey visual field analyser using the 30.2 full-threshold test. Retinal nerve fiber layers (RNFL) and optic nerve heads of patients were evaluated with Stratus OCT. Positive correlation was detected between SAP pattern standard deviation value and average intraocular pressure (P=0.017), maximum intraocular pressure (P=0.009), and vertical cup to disc (C/D) ratio (P=0.009). Positive correlation between SWAP median deviation value with inferior (P=0.032), nasal (P=0.005), 6 o'clock quadrant RNFL thickness (P=0.028), and Imax/Tavg ratio (P=0.023) and negative correlation with Smax/Navg ratio (P=0.005) were detected. There was no correlation between central corneal thickness and peripapillary RNFL thicknesses (P>0.05). There was no relation between SAP median deviation, pattern standard deviation values and RNFL thicknesses and optic disc parameters of the OCT. By contrast significant correlation between several SWAP parameters and OCT parameters were detected. SWAP appeared to outperform achromatic SAP when the same 30-2 method was used.
Accuracy of a pulse-coherent acoustic Doppler profiler in a wave-dominated flow
Lacy, J.R.; Sherwood, C.R.
2004-01-01
The accuracy of velocities measured by a pulse-coherent acoustic Doppler profiler (PCADP) in the bottom boundary layer of a wave-dominated inner-shelf environment is evaluated. The downward-looking PCADP measured velocities in eight 10-cm cells at 1 Hz. Velocities measured by the PCADP are compared to those measured by an acoustic Doppler velocimeter for wave orbital velocities up to 95 cm s-1 and currents up to 40 cm s-1. An algorithm for correcting ambiguity errors using the resolution velocities was developed. Instrument bias, measured as the average error in burst mean speed, is -0.4 cm s-1 (standard deviation = 0.8). The accuracy (root-mean-square error) of instantaneous velocities has a mean of 8.6 cm s-1 (standard deviation = 6.5) for eastward velocities (the predominant direction of waves), 6.5 cm s-1 (standard deviation = 4.4) for northward velocities, and 2.4 cm s-1 (standard deviation = 1.6) for vertical velocities. Both burst mean and root-mean-square errors are greater for bursts with ub ??? 50 cm s-1. Profiles of burst mean speeds from the bottom five cells were fit to logarithmic curves: 92% of bursts with mean speed ??? 5 cm s-1 have a correlation coefficient R2 > 0.96. In cells close to the transducer, instantaneous velocities are noisy, burst mean velocities are biased low, and bottom orbital velocities are biased high. With adequate blanking distances for both the profile and resolution velocities, the PCADP provides sufficient accuracy to measure velocities in the bottom boundary layer under moderately energetic inner-shelf conditions.
Distribution Development for STORM Ingestion Input Parameters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fulton, John
The Sandia-developed Transport of Radioactive Materials (STORM) code suite is used as part of the Radioisotope Power System Launch Safety (RPSLS) program to perform statistical modeling of the consequences due to release of radioactive material given a launch accident. As part of this modeling, STORM samples input parameters from probability distributions with some parameters treated as constants. This report described the work done to convert four of these constant inputs (Consumption Rate, Average Crop Yield, Cropland to Landuse Database Ratio, and Crop Uptake Factor) to sampled values. Consumption rate changed from a constant value of 557.68 kg / yr tomore » a normal distribution with a mean of 102.96 kg / yr and a standard deviation of 2.65 kg / yr. Meanwhile, Average Crop Yield changed from a constant value of 3.783 kg edible / m 2 to a normal distribution with a mean of 3.23 kg edible / m 2 and a standard deviation of 0.442 kg edible / m 2 . The Cropland to Landuse Database ratio changed from a constant value of 0.0996 (9.96%) to a normal distribution with a mean value of 0.0312 (3.12%) and a standard deviation of 0.00292 (0.29%). Finally the crop uptake factor changed from a constant value of 6.37e -4 (Bq crop /kg)/(Bq soil /kg) to a lognormal distribution with a geometric mean value of 3.38e -4 (Bq crop /kg)/(Bq soil /kg) and a standard deviation value of 3.33 (Bq crop /kg)/(Bq soil /kg)« less
Water vapor over Europe obtained from remote sensors and compared with a hydrostatic NWP model
NASA Astrophysics Data System (ADS)
Johnsen, K.-P.; Kidder, S. Q.
Due to its high-variability water vapor is a crucial parameter in short-term numerical weather prediction. Integrated water vapor (IWV) data obtained from a network of groundbased Global Positioning System (GPS) receivers mainly over Germany and passive microwave measurements of the Advanced Microwave Sounding Unit (AMSU-A) are compared with the high-resolution regional weather forecast model HRM of the Deutscher Wetterdienst (DWD). Time series of the IWV at 74 GPS stations obtained during the first complete year of the GFZ/GPS network between May 2000 and April 2001 are applied together with colocated forecasts of the HRM model. The low bias (0.08 kg/m 2) between the HRM model and the GPS data can mainly be explained by the bias between the ECMWF analysis data used to initilize the HRM model and the GPS data. The IWV standard deviation between the HRM model and the GPS data during that time is about 2.47 kg/ m2. GPS stations equipped with surface pressure sensors show about 0.29 kg/ m2 lower standard deviation compared with GPS stations with interpolated surface pressure from synoptic stations. The NOAA/NESDIS Total Precipitable Water algorithm is applied to obtain the IWV and to validate the model above the sea. While the mean IWV obtained from the HRM model is about 2.1 kg/ m2 larger than from the AMSU-A data, the standard deviations are 2.46 kg/ m2 (NOAA-15) and 2.29 kg/ m2 (NOAA-16) similar to the IWV standard deviation between HRM and GPS data.
Keratoconus: The ABCD Grading System.
Belin, M W; Duncan, J K
2016-06-01
To propose a new keratoconus classification/staging system that utilises current tomographic data and better reflects the anatomical and functional changes seen in keratoconus. A previously published normative database was reanalysed to generate both anterior and posterior average radii of curvature (ARC and PRC) taken from a 3.0 mm optical zone centred on the thinnest point of the cornea. Mean and standard deviations were recorded and anterior data were compared to the existing Amsler-Krumeich (AK) Classification. ARC, PRC, thinnest pachymetry and distance visual acuity were then used to construct a keratoconus classification. 672 eyes of 336 patients were analysed. Anterior and posterior values were 7.65 ± 0.236 mm and 6.26 ± 0.214 mm, respectively, and thinnest pachymetry values were 534.2 ± 30.36 µm. The ARC values were 2.63, 5.47 and 6.44 standard deviations from the mean values of stages 1-3 in the AK classification, respectively. PRC staging uses the same standard deviation gates. The pachymetric values differed by 4.42 and 7.72 standard deviations for stages 2 and 3, respectively. A new keratoconus staging incorporates anterior and posterior curvature, thinnest pachymetric values, and distance visual acuity and consists of stages 0-4 (5 stages). The proposed system closely matches the existing AK classification stages 1-4 on anterior curvature. As it incorporates posterior curvature and thickness measurements based on the thinnest point, rather than apical measurements, the new staging system better reflects the anatomical changes seen in keratoconus. Georg Thieme Verlag KG Stuttgart · New York.
A log-normal distribution model for the molecular weight of aquatic fulvic acids
Cabaniss, S.E.; Zhou, Q.; Maurice, P.A.; Chin, Y.-P.; Aiken, G.R.
2000-01-01
The molecular weight of humic substances influences their proton and metal binding, organic pollutant partitioning, adsorption onto minerals and activated carbon, and behavior during water treatment. We propose a lognormal model for the molecular weight distribution in aquatic fulvic acids to provide a conceptual framework for studying these size effects. The normal curve mean and standard deviation are readily calculated from measured M(n) and M(w) and vary from 2.7 to 3 for the means and from 0.28 to 0.37 for the standard deviations for typical aquatic fulvic acids. The model is consistent with several types of molecular weight data, including the shapes of high- pressure size-exclusion chromatography (HP-SEC) peaks. Applications of the model to electrostatic interactions, pollutant solubilization, and adsorption are explored in illustrative calculations.The molecular weight of humic substances influences their proton and metal binding, organic pollutant partitioning, adsorption onto minerals and activated carbon, and behavior during water treatment. We propose a log-normal model for the molecular weight distribution in aquatic fulvic acids to provide a conceptual framework for studying these size effects. The normal curve mean and standard deviation are readily calculated from measured Mn and Mw and vary from 2.7 to 3 for the means and from 0.28 to 0.37 for the standard deviations for typical aquatic fulvic acids. The model is consistent with several type's of molecular weight data, including the shapes of high-pressure size-exclusion chromatography (HP-SEC) peaks. Applications of the model to electrostatic interactions, pollutant solubilization, and adsorption are explored in illustrative calculations.
40 CFR 63.4312 - What records must I keep?
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Printing, Coating, and Dyeing of Fabrics and... these records is a deviation from the applicable standard. (a) A copy of each notification and report...
40 CFR 63.4312 - What records must I keep?
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutants: Printing, Coating, and Dyeing of Fabrics and Other Textiles... deviation from the applicable standard. (a) A copy of each notification and report that you submitted to...
The UNITAID Patent Pool Initiative: Bringing Patents Together for the Common Good
Bermudez, Jorge; 't Hoen, Ellen
2010-01-01
Developing and delivering appropriate, affordable, well-adapted medicines for HIV/AIDS remains an urgent challenge: as first-line therapies fail, increasing numbers of people require costly second-line therapy; one-third of ARVs are not available in pediatric formulations; and certain key first- and second-line triple fixed-dose combinations do not exist or sufficient suppliers are lacking. UNITAID aims to help solve these problems through an innovative initiative for the collective management of intellectual property (IP) rights – a patent pool for HIV medicines. The idea behind a patent pool is that patent holders - companies, governments, researchers or universities - voluntarily offer, under certain conditions, the IP related to their inventions to the patent pool. Any company that wants to use the IP to produce or develop medicines can seek a license from the pool against the payment of royalties, and may then produce the medicines for use in developing countries (conditional upon meeting agreed quality standards). The patent pool will be a voluntary mechanism, meaning its success will largely depend on the willingness of pharmaceutical companies to participate and commit their IP to the pool. Generic producers must also be willing to cooperate. The pool has the potential to provide benefits to all. PMID:20309404
Verster, Joris C; Roth, Thomas
2011-01-01
This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of ‘weaving’, is a stable measure of driving performance with high test–retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject’s baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites. PMID:21625472
Verster, Joris C; Roth, Thomas
2011-01-01
This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of 'weaving', is a stable measure of driving performance with high test-retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject's baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cao, Y; Li, R; Chi, Z
Purpose: To compare the performances of four commercial treatment planning systems (TPS) used for the intensity-modulated radiotherapy (IMRT). Methods: Ten patients of nasopharyngeal (4 cases), esophageal (3 cases) and cervical (3 cases) cancer were randomly selected from a 3-month IMRT plan pool at one radiotherapy center. For each patient, four IMRT plans were newly generated by using four commercial TPS (Corvus, Monaco, Pinnacle and Xio), and then verified with Matrixx (two-dimensional array/IBA Company) on Varian23EX accelerator. A pass rate (PR) calculated from the Gamma index by OminiPro IMRT 1.5 software was evaluated at four plan verification standards (1%/1mm, 2%/2mm, 3%/3mm,more » 4%/4mm and 5%/5mm) for each treatment plan. Overall and multiple pairwise comparisons of PRs were statistically conducted by analysis of covariance (ANOVA) F and LSD tests among four TPSs. Results: Overall significant (p>0.05) differences of PRs were found among four TPSs with F test values of 3.8 (p=0.02), 21.1(>0.01), 14.0 (>0.01), 8.3(>0.01) at standards of 1%/1mm to 4%/4mm respectively, except at 5%/5mm standard with 2.6 (p=0.06). All means (standard deviation) of PRs at 3%/3mm of 94.3 ± 3.3 (Corvus), 98.8 ± 0.8 (Monaco), 97.5± 1.7 (Pinnacle), 98.4 ± 1.0 (Xio) were above 90% and met clinical requirement. Multiple pairwise comparisons had not demonstrated a consistent low or high pattern on either TPS. Conclusion: Matrixx dose verification results show that the validation pass rates of Monaco and Xio plans are relatively higher than those of the other two; Pinnacle plan shows slight higher pass rate than Corvus plan; lowest pass rate was achieved by the Corvus plan among these four kinds of TPS.« less
The Effect of Type of Punishment on Resistance to Deviation.
ERIC Educational Resources Information Center
LaVoie, Joseph C.
The comparative effectiveness of an aversive stimulus, withholding of resources, withdrawal of love and reasoning, when used alone and combined with praise, was assessed in the standard laboratory punishment paradigm using 120 first and second graders as subjects. Resistance to deviation was used as the measure of punishment effectiveness. Sex of…
40 CFR 63.9641 - What reports must I submit and when?
Code of Federal Regulations, 2010 CFR
2010-07-01
... provide a statement that there were no deviations from the emission limitations, work practice standards... system was out-of-control during the reporting period. (7) For each deviation from an emission limitation... monitoring system (including a CPMS or COMS) to comply with an emission limitation in this subpart, the...
Jing, Wu; Guanlu, Liang; Qianyin, Zheng; Shuyi, Li; Fengying, He; Jian, Liu; Wen, Xu
2017-07-01
A meta-analysis to compare iris-claw intraocular lens (IC-IOL) and scleral-fixated posterior chamber intraocular lens (SF-PCIOL) implantations in correcting aphakia without sufficient capsular support. Eligible studies were collected through PubMed, Web of Science, Embase, and the Cochrane library. The pooled relative risks (RR), pooled standardized mean difference (SMD), and their 95% confidence interval of the eligible studies were then calculated. Seven studies met our inclusion criteria, involving 232 and 158 eyes in IC-IOL and SF-PCIOL groups, respectively. The pooled SMD of the mean postoperative corrected distance visual acuity (CDVA) (logMAR) was -0.25. The pooled RR of the eyes achieving 20/40 or better postoperatively was 1.16. The pooled SMD of the surgical time was -2.97. The pooled RR of the surgical complications was 0.86. The pooled RR of IOL dislocation, retinal detachment (RD), and cystoid macular edema (CME) between the two groups were 0.22, 0.63, and 0.64. Implantation of IC-IOL has a more simple procedure and shorter learning curve than SF-PCIOL implantation in correcting aphakia without sufficient capsular support.
Ashley, Kevin; Brisson, Michael J; Howe, Alan M; Bartley, David L
2009-12-01
A collaborative interlaboratory evaluation of a newly standardized inductively coupled plasma mass spectrometry (ICP-MS) method for determining trace beryllium in workplace air samples was carried out toward fulfillment of method validation requirements for ASTM International voluntary consensus standard test methods. The interlaboratory study (ILS) was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Uncertainty was also estimated in accordance with ASTM D7440, which applies the International Organization for Standardization Guide to the Expression of Uncertainty in Measurement to air quality measurements. Performance evaluation materials (PEMs) used consisted of 37 mm diameter mixed cellulose ester filters that were spiked with beryllium at levels of 0.025 (low loading), 0.5 (medium loading), and 10 (high loading) microg Be/filter; these spiked filters were prepared by a contract laboratory. Participating laboratories were recruited from a pool of over 50 invitees; ultimately, 20 laboratories from Europe, North America, and Asia submitted ILS results. Triplicates of each PEM (blanks plus the three different loading levels) were conveyed to each volunteer laboratory, along with a copy of the draft standard test method that each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the PEMs by one of three sample preparation procedures (hotplate or microwave digestion or hotblock extraction) that were described in the draft standard. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS and to report their data in units of mu g Be/filter sample. Interlaboratory precision estimates from participating laboratories, computed in accordance with ASTM E691, were 0.165, 0.108, and 0.151 (relative standard deviation) for the PEMs spiked at 0.025, 0.5, and 10 microg Be/filter, respectively. Overall recoveries were 93.2%, 102%, and 80.6% for the low, medium, and high beryllium loadings, respectively. Expanded uncertainty estimates for interlaboratory analysis of low, medium, and high beryllium loadings, calculated in accordance with ASTM D7440, were 18.8%, 19.8%, and 24.4%, respectively. These figures of merit support promulgation of the analytical procedure as an ASTM International standard test method, ASTM D7439.
Saunders, Luke J; Russell, Richard A; Crabb, David P
2015-01-01
Swedish Interactive Thresholding Algorithm (SITA) testing strategies for the Humphrey Field Analyzer have become a clinical standard. Measurements from SITA Fast are thought to be more variable than SITA Standard, yet some clinics routinely use SITA Fast because it is quicker. To examine the measurement precision of the 2 SITA strategies across a range of sensitivities using a large number of visual field (VF) series from 4 glaucoma clinics in England. Retrospective cohort study at Moorfields Eye Hospital in London, England; Gloucestershire Eye Unit at Cheltenham General Hospital; Queen Alexandra Hospital in Portsmouth, England; and the Calderdale and Huddersfield National Health Service Foundation Trust that included 66,974 Humphrey 24-2 SITA Standard VFs (10,124 eyes) and 19,819 Humphrey 24-2 SITA Fast VFs (3654 eyes) recorded between May 20, 1997, and September 20, 2012. Pointwise ordinary least squares linear regression of measured sensitivity over time was conducted using VF series of 1 random eye from each patient. Residuals from the regression were pooled according to fitted sensitivities. For each sensitivity (decibel) level, the standard deviation of the residuals was used to estimate measurement precision and were compared for SITA Standard and SITA Fast. Simulations of progression from different VF baselines were used to evaluate how different levels of precision would affect time to detect VF progression. Median years required to detect progression. Median (interquartile range) patient age, follow-up, and series lengths for SITA Standard were 64 (53-72) years, 6.0 (4.0-8.5) years, and 6 (4-8) VFs, respectively; for SITA Fast, medians (interquartile range) were 70 (61-78) years, 5.1 (3.2-7.3) years, and 5 (4-6) VFs. Measurement precision worsened as sensitivity decreased for both test strategies. In the 20 to 5 dB range, SITA Fast was less precise than SITA Standard; this difference was largest between 15 to 10 dB, where variability in both methods peaked. Translated to median time to detection, differences in measurement precision were negligible, suggesting minimal effects on time to detect progression. Although SITA Standard is a more precise testing algorithm than SITA Fast at lower VF sensitivities, it is unlikely to make a sizeable difference to improving the time to detect VF progression.
Lactational Stage of Pasteurized Human Donor Milk Contributes to Nutrient Limitations for Infants
Valentine, Christina J.; Morrow, Georgia; Reisinger, Amanda; Dingess, Kelly A.; Morrow, Ardythe L.; Rogers, Lynette K.
2017-01-01
Background. Mother’s own milk is the first choice for feeding preterm infants, but when not available, pasteurized human donor milk (PDM) is often used. Infants fed PDM have difficulties maintaining appropriate growth velocities. To assess the most basic elements of nutrition, we tested the hypotheses that fatty acid and amino acid composition of PDM is highly variable and standard pooling practices attenuate variability; however, total nutrients may be limiting without supplementation due to late lactational stage of the milk. Methods. A prospective cross-sectional sampling of milk was obtained from five donor milk banks located in Ohio, Michigan, Colorado, Texas-Ft Worth, and California. Milk samples were collected after Institutional Review Board (#07-0035) approval and informed consent. Fatty acid and amino acid contents were measured in milk from individual donors and donor pools (pooled per Human Milk Banking Association of North America guidelines). Statistical comparisons were performed using Kruskal–Wallis, Spearman’s, or Multivariate Regression analyses with center as the fixed factor and lactational stage as co-variate. Results. Ten of the fourteen fatty acids and seventeen of the nineteen amino acids analyzed differed across Banks in the individual milk samples. Pooling minimized these differences in amino acid and fatty acid contents. Concentrations of lysine and docosahexaenoic acid (DHA) were not different across Banks, but concentrations were low compared to recommended levels. Conclusions. Individual donor milk fatty acid and amino acid contents are highly variable. Standardized pooling practice reduces this variability. Lysine and DHA concentrations were consistently low across geographic regions in North America due to lactational stage of the milk, and thus not adequately addressed by pooling. Targeted supplementation is needed to optimize PDM, especially for the preterm or volume restricted infant. PMID:28335478
Association between dioxin and cancer incidence and mortality: a meta-analysis
NASA Astrophysics Data System (ADS)
Xu, Jinming; Ye, Yao; Huang, Fang; Chen, Hanwen; Wu, Han; Huang, Jian; Hu, Jian; Xia, Dajing; Wu, Yihua
2016-11-01
The objective of the present study was to systematically assess the association between dioxin/2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) and cancer incidence and mortality. Systematic literature searches were conducted until July 2015 in Pubmed, Embase and Cochrane library to identify relevant studies. A random-effects model was applied to estimate the pooled odds ratio (OR), risk ratio (RR), standard incidence ratio (SIR) or standard mortality ratio (SMR) for cancer incidence or mortality. In addition, dose-response, meta-regression, subgroup, and publication bias analyses were conducted. Thirty-one studies involving 29,605 cancer cases and 3,478,748 participants were included. Higher external exposure level of TCDD was significantly associated with all cancer mortality (pooled SMR = 1.09, 95% CI: 1.01-1.19, p = 0.04), but not all cancer incidence (pooled RR = 1.01, 95% CI: 0.97-1.06, p = 0.49). Higher blood level of TCDD was both significantly associated with all cancer incidence (pooled RR = 1.57, 95% CI: 1.21-2.04, p = 0.001) and all cancer mortality (pooled SMR = 1.45, 95% CI: 1.25-1.69, p < 0.001). Subgroup analysis suggested that higher external exposure and blood level of TCDD were both significantly associated with the mortality caused by non-Hodgkin’s lymphoma. In conclusion, external exposure and blood level of TCDD were both significantly associated with all cancer mortality, especially for non-Hodgkin’s lymphoma.
Jiang, Rongzhong
2007-07-01
An electrochemical cell array was designed that contains a common air electrode and 16 microanodes for high throughput screening of both fuel cells (based on polymer electrolyte membrane) and metal/air batteries (based on liquid electrolyte). Electrode materials can easily be coated on the anodes of the electrochemical cell array and screened by switching a graphite probe from one cell to the others. The electrochemical cell array was used to study direct methanol fuel cells (DMFCs), including high throughput screening of electrode catalysts and determination of optimum operating conditions. For screening of DMFCs, there is about 6% relative standard deviation (percentage of standard deviation versus mean value) for discharge current from 10 to 20 mAcm(2). The electrochemical cell array was also used to study tin/air batteries. The effect of Cu content in the anode electrode on the discharge performance of the tin/air battery was investigated. The relative standard deviations for screening of metal/air battery (based on zinc/air) are 2.4%, 3.6%, and 5.1% for discharge current at 50, 100, and 150 mAcm(2), respectively.
A Spatio-Temporal Approach for Global Validation and Analysis of MODIS Aerosol Products
NASA Technical Reports Server (NTRS)
Ichoku, Charles; Chu, D. Allen; Mattoo, Shana; Kaufman, Yoram J.; Remer, Lorraine A.; Tanre, Didier; Slutsker, Ilya; Holben, Brent N.; Lau, William K. M. (Technical Monitor)
2001-01-01
With the launch of the MODIS sensor on the Terra spacecraft, new data sets of the global distribution and properties of aerosol are being retrieved, and need to be validated and analyzed. A system has been put in place to generate spatial statistics (mean, standard deviation, direction and rate of spatial variation, and spatial correlation coefficient) of the MODIS aerosol parameters over more than 100 validation sites spread around the globe. Corresponding statistics are also computed from temporal subsets of AERONET-derived aerosol data. The means and standard deviations of identical parameters from MOMS and AERONET are compared. Although, their means compare favorably, their standard deviations reveal some influence of surface effects on the MODIS aerosol retrievals over land, especially at low aerosol loading. The direction and rate of spatial variation from MODIS are used to study the spatial distribution of aerosols at various locations either individually or comparatively. This paper introduces the methodology for generating and analyzing the data sets used by the two MODIS aerosol validation papers in this issue.
NASA Astrophysics Data System (ADS)
Kriegerowski, Martin; Rassmann, Katja; Oltrup, Theo; Bende, Thomas; Jean, Benedikt J.
1995-05-01
The refractive outcome of thermokeratoplasty depends upon the location and angle of the coagulation spots, applied with a focusing handpiece onto the corneal surface. Accuracy can be enhanced using a specially designed application mask. An astigmatism correction was performed on 10 human donor eyes (Holmium 25, Technomed, FRG, 15 Hz, 20 mJ/pulse, 25 pulses) with an optical zone of 8.1 mm, 5 eyes received a free hand laser application (marked positions) and the other 5 eyes were treated using a suctioned metal mask with drills for the handpiece (optical zone 8.1 mm). To compare the results a silicone replica was taken and analyzed by a confocal laser microtopometer. The refractive change for the steepest meridian was 10 D with a standard deviation of +/- 3.7 D for the free hand application. Using the application mask the refractive outcome was 9.8 D with a standard deviation of only 0.8 D. Using the application mask the standard deviation for the induced refractive change decreases by a factor of five.
NASA Astrophysics Data System (ADS)
Dong, Min; Dong, Chenghui; Guo, Miao; Wang, Zhe; Mu, Xiaomin
2018-04-01
Multiresolution-based methods, such as wavelet and Contourlet are usually used to image fusion. This work presents a new image fusion frame-work by utilizing area-based standard deviation in dual tree Contourlet trans-form domain. Firstly, the pre-registered source images are decomposed with dual tree Contourlet transform; low-pass and high-pass coefficients are obtained. Then, the low-pass bands are fused with weighted average based on area standard deviation rather than the simple "averaging" rule. While the high-pass bands are merged with the "max-absolute' fusion rule. Finally, the modified low-pass and high-pass coefficients are used to reconstruct the final fused image. The major advantage of the proposed fusion method over conventional fusion is the approximately shift invariance and multidirectional selectivity of dual tree Contourlet transform. The proposed method is compared with wavelet- , Contourletbased methods and other the state-of-the art methods on common used multi focus images. Experiments demonstrate that the proposed fusion framework is feasible and effective, and it performs better in both subjective and objective evaluation.
A standard deviation selection in evolutionary algorithm for grouper fish feed formulation
NASA Astrophysics Data System (ADS)
Cai-Juan, Soong; Ramli, Razamin; Rahman, Rosshairy Abdul
2016-10-01
Malaysia is one of the major producer countries for fishery production due to its location in the equatorial environment. Grouper fish is one of the potential markets in contributing to the income of the country due to its desirable taste, high demand and high price. However, the demand of grouper fish is still insufficient from the wild catch. Therefore, there is a need to farm grouper fish to cater to the market demand. In order to farm grouper fish, there is a need to have prior knowledge of the proper nutrients needed because there is no exact data available. Therefore, in this study, primary data and secondary data are collected even though there is a limitation of related papers and 30 samples are investigated by using standard deviation selection in Evolutionary algorithm. Thus, this study would unlock frontiers for an extensive research in respect of grouper fish feed formulation. Results shown that the fitness of standard deviation selection in evolutionary algorithm is applicable. The feasible and low fitness, quick solution can be obtained. These fitness can be further predicted to minimize cost in farming grouper fish.