Sample records for porcelain

  1. [A study on the color difference between Au-Pt alloy porcelain and Ni-Cr alloy porcelain].

    PubMed

    Li, Yong; Zhao, Yunfeng; Li, Hong

    2003-06-01

    To investigate the color difference between Au-Pt alloy porcelain and Ni-Cr alloy porcelain. 30 metal-ceramic specimens with different dentin porcelain thickness were fabricated with two types of metal-ceramic alloy, each type of alloy had 15 specimens. L*, a*, b* were measured after opaque porcelain was applied, and dentin porcelain was fired 1, 3, 5, 7 times by MINOLTA CR-100. Then delta E was calculated which reflected the color difference between high-gold alloy porcelain and Ni-Cr alloy porcelain. Comparing with Ni-Cr alloy porcelain, the color of Au-Pt alloy porcelain was reddish, yellowish and less bright. The delta E between high-gold alloy porcelain and Ni-Cr alloy porcelain in shade A2 was largest when opaque porcelain was applied. It decreased when dentin porcelain was applied. It became smallest when fired 3 times, and increased along with the increase of fire times. It was larger than 1.5 except firing 3 times. When dentin porcelain was applied, delta E which was larger than 1.5 among different dentin porcelain thickness decreased along with the increase of dentin porcelain thickness. The color difference between the two types of metal-ceramic alloy should be carefully taken into account in order to improve the quality of color matching.

  2. [Effect of thickness and shade of porcelain of ceramometal restorations on color of gingival porcelain].

    PubMed

    Sun, Jun; Luo, Yun; Chao, Yong-Lie

    2005-06-01

    The purpose of this study was to evaluate the color changes of gingival porcelain through varying thickness and shade of porcelain of ceramometal restorations. In this study a spectrophotometer (PR-650) was used for color analysis. The color changes of dentin porcelain and gingival porcelain with three varied thickness (0.3 mm, 0.6 mm and 0.9 mm) were investigated. In addition, the color variances of Shofu vintage porcelain shade A2, A3 and B2 were tested. The results showed that decreased L * value of ceramometal restorations and increased a * value were due to the increase of the gingival porcelain thickness, color measurements showed the same trend as the increased dentin porcelain thickness and the opaque and dentin porcelain with different color affected the appearance of gingival porcelain. The color of gingival porcelain would be changed with the differences of thickness and shade of porcelain of ceramometal restorations.

  3. [The influences of crystallized compositions in the porcelain on bonding strength of titanium to porcelain].

    PubMed

    Mo, A; Wang, J; Liao, Y; Cen, Y; Shi, X

    2001-12-01

    Sufficient porcelain-titanium bond is a vital factor determining the clinical performance of titanium-porcelain restorations. The purpose of this study was to investigate the effects of self-preparation La-porcelain composition on the porcelain-titanium bonding strength and to compare with the Vita Titankeramik. The present study examines 5 different recipes of porcelain by weight%: SiO2, 12%-17%; LaO2, 7%-10%; Al2O3, 9%-14%; B2O3, 23%-31%; CaO, 6%-8%; K2O, 2%-3%; SrO, 2%-4%; Na2O, 1%-3%; SnO2, 8%-10%; ZrO2, 3%-5%; TiO2, 6%-8%. Specimens were tested in push type shear with a universal testing machine. Scanning electron microscopy (SEM) and electron probe microanalyzer (EPMA) were employed to reveal the microstructures and diffusion of elements in the interfacial regions between the porcelain coating and titanium to the bond strength when fired at 800 degrees C. The ratios of crystallized compositions had significant influences on the porcelain-titanium bond strength (P < 0.05). La-porcelain had the highest shear bond strength (37.76 MPa). The shear bond strength of the Vita Titankeramik to titanium was 20.18 MPa. The results of SEM revealed integrity of porcelain-titanium joints in La-porcelain and a greater amount of porosity in the interface of Vita Titankeramik to titanium. EPMA analysis demonstrated the aggregation of Si and Sn in the interfacial regions and their diffusion into the titanium. Chemical compositions of porcelain and ratios of crystallized compositions play the important role in the titanium porcelain bond. La-porcelain had the highest shear bond strength and good porcelain-titanium joints. La-porcelain is a new-style low fusing porcelain/titanium system.

  4. [A study on the bond interface between low-fusing dental porcelain and pure titanium].

    PubMed

    Mo, A; Cen, Y; Liao, Y; Wang, J; Shi, X

    2001-09-01

    To evaluate the bond interface between low fusing dental porcelain and pure titanium by observing the topography and detecting the ionic diffusion in the interface area. The low fusing-porcelain La-porcelain produced by the authors or Vita Titankeramik porcelain was fused to the surfaces of pure titanium. The topography of the interface between pure titanium and porcelain, and the structure of experimental materials were observed with SEM. The state of ionic diffusion in the interface area was investigated with EPMA. Excellent permeation and diffusion of La-porcelain were observed on the surfaces of pure titanium. The diffusion of ions of stannum and silicon was discovered in the interface area. The microstructure of La-porcelain to pure titanium bond interface was finer than that of Vita Titankeramik porcelain. Excellent bond can be produced in the interface between La-porcelain and pure titanium. The bonding mechanism may involve mechanical bond and chemical bond. The ionic diffusion of stannum plays an important role in the bonding of porcelain to pure titanium.

  5. [The bonding characteristic of titanium and RG experiment porcelain].

    PubMed

    Ren, Wei-hong; Guo, Tian-wen; Tian, Jie-mo; Zhang, Yun-long

    2003-07-01

    To study the bonding characteristic of Titanium and RG experiment porcelain. 5 specimens with a size of 10 mm x 5 mm x 1.4 mm were cast from pure titanium. Then 1 mm of RG experiment opaque and body porcelain were fused on the surface of the titanium specimens. The interface of titanium and porcelain was analyzed with a scanning electron microscope with energy-despersive spectrometry; 6 metal specimens with the size of 25 mm x 3 mm x 0.5 mm were cast from Ni-Cr alloy and a uniform thickness of 1 mm of VMK 99 porcelain was veneered on the central area of 8 mm x 3 mm 18 metal specimens as the same size were cast from pure titanium. The uniform thickness of 1 mm of VITA TITANKERAMIK porcelain, of Noritake super porcelain Ti-22 and of RG experiment porcelain were veneered on every 6 specimens respectively in the central area of 8 mm x 3 mm. The specimens were subjected to a three-point bending test on a load-test machine with a span of 20 mm, then the failure loads were recorded and statistically analysised. The RG porcelain/titanium crown was fabricated by fusing RG opaque porcelain and body porcelain to cast titanium substrate crown. The SEM results show no porosity and crackle were found in the interface. The energy-dispersive spectrometry show that there are Si, Ti and O in the 1 micro m layer between porcelain and titanium, which suggesting titanium and experiment porcelain bonding well. The three point test showed the fracture force for the combinations of titanium/VITA TITANKERAMIK porcelain, titanium/Noritake super porcelain Ti-22 and titanium/RG experiment porcelain were (7.233 +/- 2.539) N, (5.533 +/- 1.199) N and (6.316 +/- 1.433) N respectively. There were not statistically significant differences among them (t test, P < 0.01). The fracture force for the Ni-Cr alloy/VMK99 porcelain combination (12.733 +/- 3.297) N was significantly greater than those of the cast titanium/porcelain (t test, P > 0.05). The crown was translucent with no crack. RG porcelain is well compatible with titanium.

  6. [Preliminary analysis about influence of porcelain thickness on interfacial crack of PFM].

    PubMed

    Zhu, Ziyuan; Zhang, Baowei; Zhang, Xiuyin; Xu, Kan; Fang, Ruhua; Wang, Dongmei

    2002-01-01

    This study was about the influence of porcelain thickness on crack at interface. The effect of porcelain thickness on the flaw at the interface between porcelain and metal was studied in three groups with porcelain thickness of 0.5 mm, 1.5 mm and 2.5 mm (metal thickness of 0.5 mm) by means of moire interferometre and interfacial fracture mechanics. The parameter Jc was compared among the three groups and the growing of the flaw was observed. Jc and the extreme strength of group with porcelain thickness of 0.5 mm (2.813 N/m and 9.979 N) were lower than those of the groups with porcelain thickness of 1.5 mm and 2.5 mm (5.395 N/m, 19.134 N and 5.429 N/m, 19.256 N). Flaws extend along the interface in the groups with porcelain thickness of 1.5 mm and 0.5 mm. (1) Fracture resistance of the interface in the groups with porcelain thickness of 1.5 mm and 2.5 mm is similar and it decreases in the group with 0.5 mm thick porcelain. (2) When porcelain is 1.5 mm or 0.5 mm thick, flaws will extend along the interface. When porcelain is 2.5 mm thick, flaws will extend into the porcelain layer.

  7. [Influence of manufacture technique on translucency and color of dental porcelain].

    PubMed

    Xiong, Fang; Chao, Yong-Lie; Zhu, Zhi-Min

    2007-12-01

    To study the influence of manufacture technique on the translucency and color of dental porcelain. Specimens were made of VITA VMK 95 dentin porcelain and enamel porcelain and divided into 3 groups: Sintering times group (1, 2, 4, 6, 8 and 10 times), sintering temperature group (910, 920, 930, 940 and 950 degrees C), sintering vacuum group (95, 65, 35 and 0 kPa). Transmittance, Y, dominant wavelength and saturation were measured by PR-650 spectra scan spectrocolorimeter. Transmittance of dentin porcelain increased after 6 times repeated sintering. Transmittance of enamel porcelain increased first after the second sintering, and then became decreasing when sintering more than 2 times. Transmittance of enamel porcelain deceased when sintering temperature was lower than standard. Decrease of sintering vacuum caused the transmittance of dentin and enamel porcelain decreased. The changing of value was coordinated with transmittance. Dominant wavelength and saturation had negative correlation with sintering times and temperature, and positive correlation with vacuum. Sintering times, temperature and vacuum all had prominent effects on the translucency and color of dental porcelain. Comparing with dentin porcelain, enamel porcelain was more sensitive with the modification of manufacture technique.

  8. Effect of porcelain and enamel thickness on porcelain veneer failure loads in vitro.

    PubMed

    Ge, Chunling; Green, Chad C; Sederstrom, Dalene; McLaren, Edward A; White, Shane N

    2014-05-01

    Bonded porcelain veneers are widely used esthetic restorations. Although high success and survival rates have been reported, failures occur. Fracture is the most common failure mode. Fractures range from incomplete cracks to the catastrophic. Minimally invasive or thin partial veneers have gained popularity. The aim of this study was to measure the influences of porcelain veneer thickness and enamel substrate thickness on the loads needed to cause the initial fracture and catastrophic failure of porcelain veneers. Model discoid porcelain veneer specimens of varying thickness were bonded to the flattened facial surfaces of incisors, artificially aged, and loaded to failure with a small sphere. Individual fracture events were identified and analyzed statistically and fractographically. Fracture events included initial Hertzian cracks, intermediate radial cracks, and catastrophic gross failure. Increased porcelain, enamel, and their combined thickness had like effects in substantially raising resistance to catastrophic failure but also slightly decreased resistance to initial Hertzian cracking. Fractographic and numerical data demonstrated that porcelain and tooth enamel behaved in a remarkably similar manner. As porcelain thickness, enamel thickness, and their combined thickness increased, the loads needed to produce initial fracture and catastrophic failure rose substantially. Porcelain veneers withstood considerable damage before catastrophic failure. Increased enamel thickness, increased porcelain thickness, and increased combined enamel and porcelain thickness all profoundly raised the failure loads necessary to cause catastrophic failure. Enamel and feldspathic porcelain behaved in a like manner. Surface contact damage occurred initially. Final catastrophic failure followed flexural radial cracking. Bonded porcelain veneers were highly damage tolerant. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. Effectiveness of Combination of Dentin and Enamel Layers on the Masking Ability of Porcelain.

    PubMed

    Boscato, Noéli; Hauschild, Fernando Gabriel; Kaizer, Marina da Rosa; De Moraes, Rafael Ratto

    2015-01-01

    This study evaluated the masking ability of different porcelain thicknesses and combination of enamel and/or dentin porcelain layers over simulated background dental substrates with higher (A2) and lower (C4) color values. Combination of the enamel (E) and dentin (D) monolayer porcelain disks with different thicknesses (0.5 mm, 0.8 mm, and 1 mm) resulted in the following bilayer groups (n=10): D1E1, D1E0.8; D1E0.5; D0.8E0.8; D0.8E0.5, and D0.5E0.5. CIELAB color coordinates were measured with a spectrophotometer. The translucency parameter of mono and bilayer specimens and the masking ability estimated by color variation (ΔE*ab) of bilayer specimens over simulated dental substrates were evaluated. Linear regression analysis was used to investigate the relationships translucency parameter × ΔE*, translucency parameter × porcelain thickness, and ΔE* × porcelain thickness. Data were analyzed statistically (α= 0.05). Thinner porcelain disks were associated with higher translucency. Porcelain monolayers were considerably more translucent than bilayers (enamel + dentin). Dentin porcelain was less translucent than enamel porcelain with same thickness. ΔE* was always lower when measured over A2 background. Higher ΔE* was observed for the C4 background, indicating poorer masking ability. Increased ΔE* was significantly associated with increased translucency for both backgrounds. Decreased translucency and ΔE* were associated with increased total porcelain thickness or increased dentin thickness for both backgrounds. In conclusion, increased porcelain thickness (particularly increased dentin layer) and increased porcelain opacity resulted in better masking ability of the dental backgrounds.

  10. [Comparison of translucency between enamel, dentin and Vita veneer porcelain].

    PubMed

    Xiong, Fang; Chao, Yong-lie; Zhu, Zhi-min

    2007-12-01

    To compare the translucency between enamel, dentin and dental porcelain. 32 newly extracted vital human central incisors were collected and cut into 0.8mm enamel slices and 1.0 mm dentin slices. 1.0 mm dental porcelain specimen were made with different Vita veneer porcelain, EN1, EN2, T4, Window, A1, A2, A3, A3.5, A4, B2, C2, D2, 3 samples for each kind. The transmittance and reflectance of tooth slices and porcelain specimen were measured by PR-650 spectra scan spectrocolorimeter. The transmittance coefficients were also calculated. The 95% confidence interval was obtained by SPSS 12.0 software package. SNK method was used to compare the transmittance coefficients of different dentin porcelains. The transmittance coefficient of tooth enamel ranged from 0.0817 mm(-1) to 0.1009 mm(-1), which was higher than that of two kinds of enamel porcelain (0.0507 mm(-1) for EN1 and 0.0408 mm(-1) for EN2). The transmittance coefficient of dentin (0.0418-0.0482 mm(-1)) was also higher than that of dentin porcelain (0.016-0.027 mm(-1)). The transmittance coefficient of dentin porcelain decreased with the increasing of chroma (P<0.05). Prominent difference exists between translucency of tooth tissue and dental porcelain, especially between enamel and enamel porcelain.

  11. Effect of different high-palladium metal-ceramic alloys on the color of opaque and dentin porcelain.

    PubMed

    Stavridakis, Minos M; Papazoglou, Efstratios; Seghi, Robert R; Johnston, William M; Brantley, William A

    2004-08-01

    The color of dental porcelain depends on the type of metal substrate. Little research has been done to document the effects of different types of high-palladium alloys on the color of dental porcelain. The purpose of this in vitro study was to evaluate the effects of different high-palladium alloys on the resulting color of dentin porcelain, as well as on that of opaque porcelain after simulated dentin and glazing firing cycles. Three Pd-Cu-Ga alloys, Spartan Plus (S), Liberty (B), and Freedom Plus (F), and 5 Pd-Ga alloys, Legacy (L), IS 85 (I), Protocol (P), Legacy XT (X), and Jelenko No.1 (N), were examined. A Pd-Ag alloy, Super Star (T), was included for comparison to the high-palladium alloys, and the Au-Pd alloy, Olympia (O), served as the control. Six cast discs (16 x 1 mm) were prepared from each of the alloys. Shade B1 opaque porcelain (Vita-Omega) was applied at a final thickness of 0.1 mm. After 2 opaque porcelain firing cycles, the surfaces were airborne-particle abraded, and the specimens were divided into 2 groups. In the first group, 0.9 mm of B1 dentin porcelain was applied. The other group of specimens with only opaque porcelain underwent the same dentin porcelain and glazing firing cycles. Color differences (DeltaE) were determined with a colorimeter between the control and each experimental group, after the second opaque porcelain, second dentin porcelain, and glazing firing cycles. One-way analysis of variance and Dunnett's multiple range test were performed on the DeltaE data (alpha=.05). After the application of dentin porcelain, the 3 Pd-Cu-Ga alloys showed significantly different (P<.05) DeltaE values (S=2.3 +/- 0.5, B=1.4 +/- 0.3, and F=1.3 +/- 0.7) than the control group. After the glazing cycle of this group, the 3 Pd-Cu-Ga alloys and the Pd-Ag alloy exhibited significantly different (P<.05) DeltaE values (S=2.8 +/- 0.8, B=2.2 +/- 0.3, F=1.9 +/- 1.0, and T=1.4 +/- 0.5) than the control group. After the simulated dentin porcelain firing cycles, the specimens with only opaque porcelain exhibited significantly different (P<.05) DeltaE values (S=5.2 +/- 1.4, B=5.4 +/- 0.6, and F=3.9 +/- 0.2) than the control group. The color difference between the 3 Pd-Cu-Ga alloys with only opaque porcelain and the control group increased more after the simulated glazing cycle (S=6.6 +/- 1.5, B=6.3 +/- 0.5, and F=4.6 +/- 0.1). The observed color differences between the Pd-Ga alloys and the control group were not statistically significant at any point. The Pd-Cu-Ga alloys with only opaque porcelain, after the simulated dentin porcelain and glazing firing cycles, exhibited clinically unacceptable color differences. The application of dentin porcelain to the Pd-Cu-Ga alloys resulted in clinically acceptable color differences. The application of dentin porcelain to the Pd-Ag alloy, after the glazing firing cycle, resulted in clinically acceptable color differences (approximately 2.8 to 3.7 DeltaE CIELAB units). The Pd-Ag alloy specimens with only opaque porcelain did not exhibit significant color differences from the control group, whereas significant color differences from the control group after the dentin porcelain and glazing firing cycles were still clinically acceptable.

  12. [Influence of different porcelain surface treatment method on the bonding of metal brackets to porcelain].

    PubMed

    Fan, Cun-Hui; Chen, Jie; Liu, Xin-Qiang; Ma, Xin

    2005-08-01

    To investigate the influence of different porcelain surface treatment methods on the shear bond strength of metal brackets bonded to porcelain. 80 porcelain facets were divided randomly into two groups according to different adhesive material that was used to bond metal brackets. Adhesive material were Jing-Jin enamel adhesive and light-cured composite resin. Each group was further divided into 4 subgroups according to different surface treatment methods, which were acid etching with 37% phosphoric acid (H3PO4), acid etching with 9.6% hydrofluoric acid (HF), deglazing by grinding and silanating the porcelain surface. All specimens were stored in 37 degrees C water for 24 hours and then the shear bond strength and the porcelain fracture after debonding was determined. The porcelain surfaces after HF etching, H3PO4 etching and deglazing by grinding were examined by scanning electron microscopy respectively. The shear bond strengths in the HF etching groups, the deglazing groups and the silanating groups were much greater than that in the phosphoric etching groups (P < 0.01). Adequate orthodontic bonding strength was achieved both when bonded with light-cured composite resin after deglazing by grinding and when bonded with either of these adhesives after HF etching or surface silanating. There were no differences in the rates of porcelain fractures among groups (P > 0.05). HF etching, deglazing by grinding and silanating can all increase the shear bond strength between metal bracket and porcelain. Surface silanating of porcelain is a better surface treatment when metal brackets bonded to porcelain.

  13. [Effects of three types of veneering porcelain on bending strength of KAVO(TM) Y-TZP/porcelain bilayered structure].

    PubMed

    Ma, Ting-ting; Yi, Yuan-fu; Shao, Long-quan; Tian, Jie-mo; Hou, Kang-lin; Zhang, Wei-wei; Wen, Ning; Deng, Bin

    2010-10-01

    To investigate the effect of three types of veneering porcelain on the bending strength of KAVO Y-TZP/porcelain layered structure. KAVO zirconia ceramics were used as the substructure. To form Y-TZP/porcelain bilayered structure, a leucite-based veneering porcelain was fired on the zirconia substructures by slip-casting technique with dentin washbake, and two nano-fluorapatite-based veneering porcelains were fired on the zirconia substructures by either slip-casting or pressed-on technique with or without liner coverage. The bending strength was tested according to ISO 6872 standard, and the veneered surfaces of the fracture samples were analyzed by scanning electron microscopy (SEM). For covering KAVO zirconia core material, the conventional veneering slurry-porcelain combined with liner or wash firing had significant higher bending strength than pressed-on porcelain. SEM showed that the main failure type at the interface was adhesive failure. Thin layer sintering using washbake program or liner on KAVO zirconia surface increases the surface wettability, and this procedure may be indispensable when veneering on the surface of dental zirconia.

  14. Addition of platinum and silver nanoparticles to toughen dental porcelain.

    PubMed

    Fujieda, Tokushi; Uno, Mitsunori; Ishigami, Hajime; Kurachi, Masakazu; Wakamatsu, Nobukazu; Doi, Yutaka

    2012-01-01

    Several studies have investigated toughening porcelain that is layered over a frame or a core. The introduction of residual compressive stress to the surface of porcelain has been shown to be effective to strengthen it. In the present study, nanoparticles of precious metals of silver and platinum (rather than non-precious metals) were used to evaluate if they could increase the fracture resistance of porcelain. The addition of silver and platinum nanoparticles was found to improve the mechanical properties of porcelain since it increased both the Young's modulus and the fracture toughness of commercial porcelain.

  15. Hardness characteristic of dental porcelain synthesized from Indonesian natural sand

    NASA Astrophysics Data System (ADS)

    Gunawan, J.; Taufik, D.; Takarini, V.; Hasratiningsih, Z.; Ramelan, A.

    2018-02-01

    Porcelain has been one of dental biomaterials which can be used to restore tooth structure. Veneer and jacket crown were the examples of dental porcelain restoration. Since wear resistance is related to the strength on its surface, then Vickers Hardness Test of the synthesized porcelain was applied subsequently. If the porcelain hardness number is too high, it should be considered that an abrasion of the opposing teeth could occur. On previous research, dental porcelain had been successfully synthesized from Indonesian natural sand. In this experiment, 5 samples were prepared from a mixture of 65w/o Pangaribuan feldspar, 25w/o Belitung silica, 5w/o Sukabumi kaolinite, and 5w/o potassium salt. This synthesized porcelain samples were invested on 5 cm diameter resin each. A kilogram of load was placed on top of each sample for 10 seconds on 7 different indented areas using ZwickRoell Indentec ZHVμ Micro Vickers. The average hardness number of synthesized dental porcelain made from Indonesian natural sand was 936.06 VHN which was higher than the average hardness number of porcelain restoration. In conclusion of the hardness test, synthesized dental porcelain made from Indonesian natural sand can potentially be used as a core, which shall support hardness and strength of the crown restoration.

  16. [Influence of different surface roughness of opaque porcelain on reflectance and L* value of porcelain fused to metal].

    PubMed

    Wang, Hui; Xiong, Fang; Yu, Hai-yang; Luo, Zhen-hua

    2009-08-01

    The purpose of this study was to investigate how different surface roughness of opaque porcelain influence reflectance and CIE L* value of porcelain fused to metal (PFM) restorations. 48 casted Ni-Cr alloy metal specimens (12.0 mm x 1.0 mm) were fabricated with ShoFu Vintage Halo porcelain and divided into six groups, eight pieces for each group. The specimens in the first group without polishing were used as control. Other groups were polished against 200-, 400-, 600-, 800-, and 1000-grit sandpaper after sintered, respectively. Surface roughness and color parameters of the specimens were measured with a Surface Roughometer EX2154-13 and a spectrocolorimeter, respectively. Ra (arithmetical mean deviation of the profile) was the main standard value to describe the surface roughness of many kinds of meatal or porcelain materials, and here we used it to express surface roughness of opaque porcelain. The data were statistically analyzed by one-way analysis of variance (alpha = 0.05) in SPSS 13.0. The reflectance value increased from 72.386 +/- 3.953 to 78.671 +/- 3.408, and CIE L* value from 90.189 +/- 1.200 to 93.496 +/- 1.070 with the increasing of surface roughness (Ra) of opaque porcelain from (0.226 +/- 0.069) microm to (0.706 +/- 0.082) microm. The same magnitude were also observed after body porcelain and enamel porcelain were sintered on with reflectance increased from 76.301 +/- 3.097 to 81.529 +/- 4.028, and CIE L* value from 80.694 +/- 1.564 to 84.604 +/- 2.964. The surface roughness of opaque porcelain had effects on the reflectance and value of PFM restorations. Within the limitation of this study, the recommended Ra range of opaque porcelain was 0.23-0.50 microm.

  17. [Preliminary study of bonding strength between diatomite-based dental ceramic and veneering porcelains].

    PubMed

    Lu, Xiao-li; Gao, Mei-qin; Cheng, Yu-ye; Zhang, Fei-min

    2015-04-01

    In order to choose the best veneering porcelain for diatomite-based dental ceramic substrate, the bonding strength between diatomite-based dental ceramics and veneering porcelains was measured, and the microstructure and elements distribution of interface were analyzed. The coefficient of thermal expansion (CTE) of diatomite-based dental ceramics was detected by dilatometry. Three veneering porcelain materials were selected with the best CTE matching including alumina veneering porcelain (group A), titanium porcelain veneering porcelain (group B), and E-max veneering porcelain (group C). Shear bonding strength was detected. SEM and EDS were used to observe the interface microstructure and element distribution. Statistical analysis was performed using SPSS 17.0 software package. The CTE of diatomite-based dental ceramics at 25-500 degrees centigrade was 8.85×10-6K-1. The diatomite-based substrate ceramics combined best with group C. Shear bonding strength between group A and C and group B and C both showed significant differences(P<0.05). SEM and EDS showed that the interface of group C sintered tightly and elements permeated on both sides of the interface. The diatomite-based substrate ceramics combines better with E-max porcelain veneer.

  18. Saylorville Stage 3 Contract Completion Report: Testing of Priority 1 Archaeological Sites 1980-1981.

    DTIC Science & Technology

    1982-02-01

    ware porcelain vessel fragments 26 23 3 25 1 - - Porcelain "china" doll fragments 3 3 - 3 - - Porcelain door knob A insulator fraqments 6 6 - 6...34 doll fragments 3 3 - 3 - Porcelain door knob & insulator fraqments 6 6 - 6 - Decorated & white ware ironstone vessel fragments 85 82 3 85 - Stoneware...77 - - - - Stoneware or kaolin pipe fragments 2 2 - - 2 - - - - Porcelain insulator fragment 1 1 - - I - - - - Glazed brick fraqment I I - - I

  19. Investigation on the Tribological Behavior and Wear Mechanism of Five Different Veneering Porcelains

    PubMed Central

    Min, Jie; Zhang, Qianqian; Qiu, Xiaoli; Zhu, Minhao; Yu, Haiyang; Gao, Shanshan

    2015-01-01

    Objectives The primary aim of this research was to investigate the wear behavior and wear mechanism of five different veneering porcelains. Methods Five kinds of veneering porcelains were selected in this research. The surface microhardness of all the samples was measured with a microhardness tester. Wear tests were performed on a ball-on-flat PLINT fretting wear machine, with lubrication of artificial saliva at 37°C. The friction coefficients were recorded by the testing system. The microstructure features, wear volume, and damage morphologies were recorded and analyzed with a confocal laser scanning microscope and a scanning electron microscope. The wear mechanism was then elucidated. Results The friction coefficients of the five veneering porcelains differ significantly. No significant correlation between hardness and wear volume was found for these veneering porcelains. Under lubrication of artificial saliva, the porcelain with higher leucite crystal content exhibited greater wear resistance. Additionally, leucite crystal size and distribution in glass matrix influenced wear behavior. The wear mechanisms for these porcelains were similar: abrasive wear dominates the early stage, whereas delamination was the main damage mode at the later stage. Furthermore, delamination was more prominent for porcelains with larger crystal sizes. Significance Wear compatibility between porcelain and natural teeth is important for dental restorative materials. Investigation on crystal content, size, and distribution in glass matrix can provide insight for the selection of dental porcelains in clinical settings. PMID:26368532

  20. The influence of multiple firing on thermal contraction of ceramic materials used for the fabrication of layered all-ceramic dental restorations.

    PubMed

    Isgrò, Giuseppe; Kleverlaan, Cornelis J; Wang, Hang; Feilzer, Albert J

    2005-06-01

    During the production of layered all-ceramic restorations transient and/or residual thermal stresses may be formed which may affect a restoration's longevity. The aim of this study was to evaluate the influence of multiple firings on the thermal behavior of veneering porcelains and a ceramic core. The materials tested were: Empress 2 Core, Empress 2 Veneer and Eris glass-ceramics, Carrara Vincent and an experimental leucite-based veneering porcelain, Vitadur-Alpha aluminous porcelain, and two porcelains designed for titanium (i.e. Duceratin Dentine and Enamel). The thermal contraction coefficient of the materials was measured by means of dilatometery. The thermal contraction coefficient was measured during cooling and calculated over the temperature range of 450-20 degrees C by linear regression. One and two-way analysis of variance together with Tukey post-hoc tests were used as statistical analysis. Repeated firing affects the thermal contraction coefficients of Empress 2 Veneer, Carrara Vincent porcelain and the experimental porcelain. The thermal contraction coefficients of Empress 2 Core were significantly different from Vitadur-Alpha, Carrara Vincent, experimental porcelain, and Duceratin porcelains. The contraction coefficients of Empress 2 Veneer and Eris were closest to that of Empress 2 Core. The Empress 2 Core and Eris glass-ceramics, the aluminous porcelain and Duceratin porcelains showed better thermal stability after repeated firing than leucite porcelains. It can be concluded that due to the thermal stability of glass-ceramic materials, layered all-ceramic restorations of these materials may perform better.

  1. A comparison between the shear bond strength of brackets bonded to glazed and deglazed porcelain surfaces with resin-reinforced glass-ionomer cement and a bis-GMA resin adhesive.

    PubMed

    Lifshitz, Abraham B; Cárdenas, Marianela

    2006-01-01

    This study compared the shear bond strength of a light-cure resin-reinforced glass-ionomer cement with a bis-GMA light-cure resin system in the bonding of stainless steel brackets to glazed and deglazed porcelain surfaces. Porcelain surfaces were divided into 4 groups: group 1, deglazed porcelain surfaces with Transbond XT, group 2, glazed porcelain surfaces with Transbond XT; group 3, deglazed porcelain surfaces with Fuji Ortho LC; and group 4, porcelain surfaces with Fuji Ortho LC. Microetching with 50-microm aluminum oxide for 2 seconds at a distance of 5 mm deglazed the porcelain surfaces in groups 1 and 3. All brackets were bonded to the porcelain surfaces using the same procedure and light-cured for 40 seconds with a visible light. All samples were thermocycled between 5 degrees C and 55 degrees C for 300 cycles before testing for shear bond strength with a universal testing machine. The analysis of variance showed no significant difference (P < .05) among the 4 groups; ie, group 1, 10.12 MPa; group 2, 7.00 MPa; group 3, 6.78 MPa; and group 4, 11.15 MPa. The F test also failed to demonstrate any statistical difference among the groups. Conditioning the porcelain surfaces with 37% phosphoric acid immediately followed by a nonhydrolyzed silane coupling agent resulted in clinically adequate bond strength when using either a composite resin or a resin-reinforced glass-ionomer cement. Microetching of these porcelain surfaces apparently offers no bonding advantage.

  2. 21 CFR 872.6660 - Porcelain powder for clinical use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Porcelain powder for clinical use. 872.6660... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6660 Porcelain powder for clinical use. (a) Identification. Porcelain powder for clinical use is a device consisting of a mixture of kaolin...

  3. 46 CFR 111.01-13 - Limitations on porcelain use.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Limitations on porcelain use. 111.01-13 Section 111.01-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS General § 111.01-13 Limitations on porcelain use. Porcelain must not be used...

  4. [Analysis of chromatic value of gingival porcelain].

    PubMed

    Wang, Min; Sun, Jun; Chao, Yong-Lie

    2005-08-01

    To study the distribution of the chromatic value of gingival porcelains. The color change of Shofu VINTAGE and Vita VMK95 gingival porcelains on the black and white backings was determined with a spectrophotometer (PR-650). The results showed that the chromatic value of gingival porcelains was different on varying backings. The color space of gingival porcelain was L*: 41.85 - 50.64, a*: 12.46 - 19.46, b*: 1.33 - 4.62. The chromatic value distribution cannot cover the color region of natural gingiva.

  5. Mössbauer study of the Ru porcelain of Chinese Song Dynasty and Yuan Dynasty

    NASA Astrophysics Data System (ADS)

    Zhengyao, Gao; Songhua, Chen; Xiande, Chen

    1994-12-01

    The Mössbauer spectra from the glazes of the Song Dynasty and the Yuan Dynasty Ru porcelains and the imitative ancient Ru porcelain are compared and analyzed. It is determined that the original firing atmosphere of the Yuan Dynasty Ru porcelain was reductive. The firing temperature was 1250±20 ‡C. The original firing atmosphere of the Song Dynasty Ru porcelain was also reductive; the firing temperature was above 1200 ‡C. The coloring mechanism of these glazes is discussed.

  6. Archaelogical Excavations of the Gardens and Interior Areas of Houses B and C of the Southeast Row Houses Fort Michilimackinac, Michigan.

    DTIC Science & Technology

    1981-08-01

    porcelain fragments recovered were Group I, Chinese Export Porcelain . No evidence of Group II, English Porcelain , was present. There were 40 fragments...earthenware, stoneware and porcelain . Distribution of colonial ceramics by unit and level appears in Appendices 2 31 and 3. Therefore, only classes and...unidentifiable fragments of stoneware. Similar to the earthenware, they were not identified because of being burned or too small. Class C Porcelain All

  7. Improved bonding of adhesive resin to sintered porcelain with the combination of acid etching and a two-liquid silane conditioner.

    PubMed

    Kato, H; Matsumura, H; Ide, T; Atsuta, M

    2001-01-01

    This study determined the bond strengths of adhesive resins joined to a feldspathic porcelain (VMK 68) for the purpose of developing the most durable surface preparation for the porcelain. Three porcelain surfaces-ground, air-abraded with alumina, and etched with hydrofluoric acid-were prepared. A two-liquid porcelain conditioner that contained both 4-methacryloyloxyethyl trimellitate anhydride (4-META) and a silane coupler (Porcelain Liner M) was used as the priming agent. Each of the two liquid components of the conditioner was also used individually in order to examine the effects of the respective chemical ingredients on adhesive bonding. Two methyl methacrylate (MMA)-based resins initiated with tri-n-butylborane (TBB) either with or without 4-META (MMA-TBB and 4-META/MMA-TBB resins) were used as the luting agents. Shear bond strengths were determined both before and after thermocycling. Shear testing results indicated that thermocycling was effective for disclosing poor bonding systems, and that both mechanical and chemical retention were indispensable for bonding the porcelain. Of the combinations assessed, etching with hydrofluoric acid followed by two-liquid priming with the Porcelain Liner M material generated the most durable bond strength (33.3 MPa) for the porcelain bonded with the 4-META/MMA-TBB resin (Super-Bond C&B).

  8. Effect of tooth substrate and porcelain thickness on porcelain veneer failure loads in vitro.

    PubMed

    Ge, Chunling; Green, Chad C; Sederstrom, Dalene A; McLaren, Edward A; Chalfant, James A; White, Shane N

    2017-12-19

    Bonded porcelain veneers are widely used esthetic restorations. High success and survival rates have been reported, but failures do occur. Fractures are the commonest failure mode. Minimally invasive or thin veneers have gained popularity. Increased enamel and porcelain thickness improve the strength of veneers bonded to enamel, but less is known about dentin or mixed substrates. The purpose of this in vitro study was to measure the influences of tooth substrate type (all-enamel, all-dentin, or half-dentin-half-enamel) and veneer thickness on the loads needed to cause initial and catastrophic porcelain veneer failure. Model discoid porcelain veneer specimens of varying thicknesses were bonded to the flattened facial surfaces of incisors with different enamel and dentin tooth substrates, artificially aged, and loaded to failure with a small sphere. Initial and catastrophic fracture events were identified and analyzed statistically and fractographically. Fracture events included initial Hertzian cracks, intermediate radial cracks, and catastrophic gross failure. All specimens retained some porcelain after catastrophic failure. Cement failure occurred at the cement-porcelain interface not at the cement-tooth interface. Porcelain veneers bonded to enamel were substantially stronger and more damage-tolerant than those bonded to dentin or mixed substrates. Increased porcelain thickness substantially raised the loads to catastrophic failure on enamel substrates but only moderately raised the loads to catastrophic failure on dentin or mixed substrates. The veneers bonded to half-dentin-half-enamel behaved remarkably like those bonded wholly to dentin. Porcelain veneers bonded to enamel were substantially stronger and more damage-tolerant than those bonded to dentin or half-enamel-half dentin. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. [Effects of different surface conditioning agents on the bond strength of resin-opaque porcelain composite].

    PubMed

    Liu, Wenjia; Fu, Jing; Liao, Shuang; Su, Naichuan; Wang, Hang; Liao, Yunmao

    2014-04-01

    The objective of this research is to evaluate the effects of different silane coupling agents on the bond strength between Ceramco3 opaque porcelain and indirect composite resin. Five groups of Co-Cr metal alloy substrates were fabricated according to manufacturer's instruction. The surface of metal alloy with a layer of dental opaque porcelain was heated by fire. After the surface of opaque porcelain was etched, five different surface treatments, i.e. RelyX Ceramic Primer (RCP), Porcelain Bond Activator and SE Bond Primer (mixed with a proportion of 1:1) (PBA), Shofu Porcelain Primer (SPP), SE bond primer (SEP), and no primer treatment (as a control group), were used to combine P60 and opaque porcelain along with resin cement. Shear bond strength of specimens was tested in a universal testing machine. The failure modes of specimens in all groups were observed and classified into four types. Selected specimens were subjected to scanning electron microscope and energy disperse spectroscopy to reveal the relief of the fracture surface and to confirm the failure mode of different types. The experimental results showed that the values of the tested items in all the tested groups were higher than that in the control group. Group PBA exhibited the highest value [(37.52 +/- 2.14) MPa] and this suggested a fact that all of the specimens in group PBA revealed combined failures (failure occurred in metal-porcelain combined surface and within opaque porcelain). Group SPP and RCP showed higher values than SEP (P < 0.05) and most specimens of SPP and RCP performed combined failures (failure occurred in bond surface and within opaque porcelain or composite resin) while all the specimens in group SEP and control group revealed adhesive failures. Conclusions could be drawn that silane coupling agents could reinforce the bond strength of dental composite resin to metal-opaque porcelain substrate. The bond strength between dental composite resin and dental opaque porcelain could meet the clinical requirements.

  10. 49 CFR 178.523 - Standards for composite packagings with inner glass, porcelain, or stoneware receptacles.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., porcelain, or stoneware: (1) 6PA1 for glass, porcelain, or stoneware receptacles within a protective steel drum; (2) 6PA2 for glass, porcelain, or stoneware receptacles within a protective steel crate or box... good quality materials free from any defect that could impair their strength, and be firmly secured in...

  11. 49 CFR 178.523 - Standards for composite packagings with inner glass, porcelain, or stoneware receptacles.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., porcelain, or stoneware: (1) 6PA1 for glass, porcelain, or stoneware receptacles within a protective steel drum; (2) 6PA2 for glass, porcelain, or stoneware receptacles within a protective steel crate or box... good quality materials free from any defect that could impair their strength, and be firmly secured in...

  12. 49 CFR 178.523 - Standards for composite packagings with inner glass, porcelain, or stoneware receptacles.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., porcelain, or stoneware: (1) 6PA1 for glass, porcelain, or stoneware receptacles within a protective steel drum; (2) 6PA2 for glass, porcelain, or stoneware receptacles within a protective steel crate or box... good quality materials free from any defect that could impair their strength, and be firmly secured in...

  13. Porcelain thickness and cement shade effects on the colour and translucency of porcelain veneering materials.

    PubMed

    Kürklü, Duygu; Azer, Shereen S; Yilmaz, Burak; Johnston, William M

    2013-11-01

    Purposes of this in vitro study include evaluating colour changes in combinations of feldspathic porcelain and cement resulting from different thicknesses of porcelain and different shades of composite luting agent, and evaluating relative translucency parameter (RTP) values. Porcelain discs of shade A1 at nominal thicknesses of 0.5 and 1.0mm were bonded to cements of three shades in a factorial design. Colours were calculated for CIE D65 Illuminant and Standard Human Observer on black, grey and white backings. A colour difference (CD) was calculated of each possible pair of different porcelain thickness values for the same cement shade and each possible pair of different cement shades for the same porcelain thickness. RTP was analyzed by ANOVA and selected pairwise comparisons. All mean CDs studied were perceptible and most were at or greater than the clinical acceptability threshold, with the notable exception that the mean CDs and their confidence limits were below the clinical acceptability threshold for a change in porcelain thickness when utilizing the Clear cement shade. Variation in the shade of the resin luting cement will result in CDs which are near or beyond clinical acceptability. A decrease in porcelain thickness did significantly increase RTP when bonded to the resin cement shades studied. Changes in porcelain thickness or cement shade may adversely affect basic aesthetic properties of these materials. Development of methods for analyzing aesthetic effects over greater ranges of thickness for these materials would improve the prognosis for using these materials. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. [Adhesion of oral microorganisms on dental porcelain polished and glazed].

    PubMed

    Wang, Yi-ning; Wen, Guo-jiang; Shi, Bin; Pan, Xin-hua

    2003-09-01

    This study compared the roughness of porcelain polished or glazed surfaces and the adhesion of oral streptococcus mutans to them in vitro. 30 porcelain samples were made. Porcelain samples in group A were polished with diamond paste. Porcelain samples were glazed in group B and were polished with Al2O3 (240#) bur in group C. Their roughness values were measured by profilometer. Standardized cell suspensions were incubated with test samples for one hour at 37 degrees C, then retained cells were counted by image analysis (percentage area of a microscopic field covered by cells). Roughness values of group A, B, C were respectively (0.1987 +/- 0.057) microm, (0.1990 +/- 0.091) microm, (0.4260 +/- 0.174) microm. There was no significantly difference between group A and group B. The roughness samples in group C were significantly rougher than that in the other groups. The amount of retained cells in group A, group B, group C was respectively (15.92 +/- 4.37)%, (16.39 +/- 6.31)% and (41.48 +/- 12.1)%. There was no significant difference between the cell adhesion on porcelain surface glazed and polished, but more bacteria adhered on the porcelain surface in group C. Porcelain surface polished treatment was clinically acceptable compared with its glazed. They all exhibited the least amount of bacteria adhesion. The more porcelain surface was rough, the more bacteria adhered on it.

  15. [Fatigue damage analysis of porcelain in all-ceramic crowns].

    PubMed

    Liu, Yi-hong; Feng, Hai-lan; Liu, Guang-hua; Shen, Zhi-jian

    2010-02-18

    To investigate the fatigue damage mechanism of porcelain, and its relation with the microscopic defects in clinically failed all-ceramic crowns. Collecting the bilayered all-ceramic crowns failed in vivo. The fractured surfaces and occlusial surfaces of failed crowns were examined by an optical microscope followed by detailed fractography investigations using a field emission scanning electron microscope. When chemical impurities were of concern, energy-dispersive X-ray spectroscopy analysis was performed to examine chemical composition. A standard practice for fractography failure analysis of advanced ceramics is applied to disclose the fracture mode, and damage character. Three types of fracture features are defined as breakdown of the entire crown, and porcelain chipping-off/delamination. Alumina crowns were usually characterized by breakdown of the entire crown, while zirconia crowns by porcelain chipping-off and delamination. The fatigue damage of porcelain was classified into surface wear, cone crack, and porcelain delamination. The observed microscopic defects in this study included air bubbles and impurity particles. The multi-point occlusial contacts were recommended in all-ceramic restorations clinically. The thickness of porcelain is important for the anti-fatigue ability of porcelain. Cautions have to be taken to avoid contaminations during the veneering processes.

  16. [Effects of laser welding on bond of porcelain fused cast pure titanium].

    PubMed

    Zhu, Juan-fang; He, Hui-ming; Gao, Bo; Wang, Zhong-yi

    2006-04-01

    To investigate the influence of the laser welding on bond of porcelain fused to cast pure titanium. Twenty cast titanium plates were divided into two groups: laser welded group and control group. The low-fusing porcelain was fused to the laser welded cast pure titanium plates at fusion zone. The bond strength of the porcelain to laser welded cast pure titanium was measured by the three-point bending test. The interface of titanium and porcelain was investigated by scanning electron microscopy (SEM) and energy depressive X-ray detector (EDX). The non-welded titanium plates were used as comparison. No significant difference of the bond strength was found between laser-welded samples [(46.85 +/- 0.76) MPa] and the controls [(41.71 +/- 0.55) MPa] (P > 0.05). The SEM displayed the interface presented similar irregularities with a predominance. The titanium diffused to low-fusing porcelain, while silicon and aluminum diffused to titanium basement. Laser welding does not affect low-fusing porcelain fused to pure titanium.

  17. [Influence of repeated sintering on the color of two brands of porcelain-fused-to-titanium].

    PubMed

    Shu, Cheng-jun; Luo, Xiao-ping; Wu, Lie

    2007-08-01

    To investigate the influence of repeated sintering on the color of two porcelain-fused-to-titanium, and the differences between the two porcelains. Thirty samples were prepared and sintered for 9 times. The color of samples were measured following sintering 1, 3, 5, 7, 9 times by ShadeEye NCC colorimeter according to two brands of porcelains with CIE1976L*a*b* color system, and calculated relevant chrome, chromatism and hue, and statistical analysis. When two brands of porcelains were sintered 5 times, the color parameters had no significant change and sintered continuely, the color parameters of L* and a* had obvious changes, but can't be observed by eyes. The color parameters of titanium-porcelains have no significant change after repeated sintering.

  18. Porcelain-coated antenna for radio-frequency driven plasma source

    DOEpatents

    Leung, Ka-Ngo; Wells, Russell P.; Craven, Glen E.

    1996-01-01

    A new porcelain-enamel coated antenna creates a clean plasma for volume or surface-conversion ion sources. The porcelain-enamel coating is hard, electrically insulating, long lasting, non fragile, and resistant to puncture by high energy ions in the plasma. Plasma and ion production using the porcelain enamel coated antenna is uncontaminated with filament or extraneous metal ion because the porcelain does not evaporate and is not sputtered into the plasma during operation. Ion beams produced using the new porcelain-enamel coated antenna are useful in ion implantation, high energy accelerators, negative, positive, or neutral beam applications, fusion, and treatment of chemical or radioactive waste for disposal. For ion implantation, the appropriate species ion beam generated with the inventive antenna will penetrate large or small, irregularly shaped conducting objects with a narrow implantation profile.

  19. Non-destructive analysis and appraisal of ancient Chinese porcelain by PIXE

    NASA Astrophysics Data System (ADS)

    Cheng, H. S.; Zhang, Z. Q.; Xia, H. N.; Jiang, J. C.; Yang, F. J.

    2002-05-01

    This paper reports the results of the PIXE analysis on ancient Chinese blue and white porcelain fired at Kuan Kiln (Jingdezhen, Jiangxi province) during 13-19th century. The major, minor and trace element of porcelain body, white glaze and blue glaze were determined by PIXE. In this paper the chemical compositions of porcelain body, white glaze and blue glaze measured from Yuan (AD 1206-1368), Ming (AD 1368-1644) and Qing (AD 1616-1911) blue and white porcelain are present. The cobalt blue pigment used in Yuan, Ming and Qing are also discussed.

  20. An in vitro study of the effect of different restorative materials on the reliability of a veneering porcelain.

    PubMed

    Anderson, Matthew R; Chung, Kwok-Hung; Flinn, Brian D; Raigrodski, Ariel J

    2013-12-01

    Implant-supported, porcelain veneered restorations experience a greater rate of porcelain fracture than tooth-supported restorations. For completely edentulous patients, one approach to minimizing porcelain fracture is to use acrylic resin in the mandible, although its efficacy is unknown. The purpose of this study was to evaluate the reliability of a veneering porcelain fatigued with different restorative materials in vitro. Fifty-nine veneering porcelain disk specimens were fabricated by layering veneering porcelain on nickel-chromium base metal alloy disks. Four groups of different indenter materials fatigued the porcelain specimens: group WC, tungsten carbide served as a control; group FC, pressed leucite glass ceramic; group NHC, nanohybrid composite resin denture tooth; and group AR, unfilled acrylic resin denture tooth. Porcelain specimens were randomly divided into 4 groups (n=14). A step-stress accelerated life-testing model was used. Use-level probability Weibull plots were generated, and the reliability of each group was estimated for a theoretical completion of 50 000 cycles at 150 N. Nanohybrid composite resin and unfilled acrylic resin denture tooth groups had higher reliability than tungsten carbide and leucite glass ceramic groups. No significant differences existed between the reliability of the tungsten carbide and leucite glass ceramic groups and the nanohybrid composite resin and acrylic resin denture tooth groups. Veneering porcelain disk specimens fatigued with the unfilled acrylic resin and nanohybrid composite resin denture tooth indenters exhibited higher reliability than the specimens fatigued with either the tungsten carbide or leucite glass ceramic indenters. All of the veneering porcelain disk specimens failed with the same mode of fracture, although the surface posttest exhibited different fracture characteristics among specimens fatigued with the 4 different materials. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  1. Analysis of elemental composition of porcelains unearthed from Waguantan kiln site by PIXE-RBS

    NASA Astrophysics Data System (ADS)

    Zhou, Z.; Zhang, K.; Xia, C. D.; Liu, M. T.; Zhu, J. J.; An, Z.; Bai, B.

    2015-03-01

    A method combining proton-induced X-ray emission spectrometry (PIXE) and Rutherford backscattering spectrometry (RBS) was used to determine the composition of 61 porcelain shards from the Yuan Dynasty (1271-1368 A.D.) unearthed from the Waguantan kiln site at Tianzhu County in Guizhou Province, China. Based on our previous experimental setup, an electron gun device with a LaB6 crystal cathode was installed to solve the problem created when the incident proton beams generated electric charge accumulations on the surfaces of the insulating porcelain samples, which induced a large bremsstrahlung background. The use of the electron gun has largely eliminated the large bremsstrahlung background and has therefore improved the detection limits for elements, especially for trace elements, and made it possible to determine the origin of the porcelains based on the trace elements. Major and trace elemental compositions of the porcelain bodies and glazes measured by PIXE and RBS were analyzed by the factor analysis method. The factor analysis showed that a few pieces of porcelain with a style similar to the porcelain of the Longquan kiln among the unearthed porcelains from the Waguantan kiln site did not have obvious differences in elemental compositions from other remaining porcelains unearthed from the Waguantan kiln site, indicating that the pieces of unearthed porcelain with the Longquan kiln style did in fact belong to the product fired locally by imitating the model of the Longquan celadon with local raw materials. This result therefore indicated that the Longquan kiln technology that originated from the Five Dynasties (907-960 A.D.) had been propagated to the Waguantan kiln site of Guizhou Province in the Yuan Dynasty.

  2. Effects of porcelain thickness on the flexural strength and crack propagation in a bilayered zirconia system.

    PubMed

    Figueiredo, Viviane Maria Gonçalves de; Pereira, Sarina Maciel Braga; Bressiani, Eduardo; Valera, Márcia Carneiro; Bottino, Marco Antônio; Zhang, Yu; Melo, Renata Marques de

    2017-01-01

    This study evaluated the influence of porcelain (VM9, VITA Zahnfabrik, Germany) thickness on the flexural strength and crack propagation in bilayered zirconia systems (YZ, VITA Zahnfabrik, Germany). Thirty zirconia bars (20.0x4.0x1.0 mm) and six zirconia blocks (12.0x7.5x1.2 mm) were prepared and veneered with porcelain with different thickness: 1 mm, 2 mm, or 3 mm. The bars of each experimental group (n=10) were subjected to four-point flexural strength testing. In each ceramic block, a Vickers indentation was created under a load of 10 kgf for 10 seconds, for the propagation of cracks. The results of flexural strength were evaluated by One-way ANOVA and Tukey's test, with a significance level of 5%. The factor "thickness of the porcelain" was statistically significant (p=0.001) and the l-mm group presented the highest values of flexural strength. The cracks were predominant among the bending specimens with 1 and 2 mm of porcelain, and catastrophic failures were found in 50% of 3-mm-thick porcelain. After the indentation of blocks, the most severe defects were observed in blocks with 3-mm-thick porcelain. The smallest (1 mm) thickness of porcelain on the zirconia infrastructure presented higher values of flexural strength. Better resistance to defect propagation was observed near the porcelain/ zirconia interface for all groups. Higher flexural strength was found for a thinner porcelain layer in a bilayered zirconia system. The damage caused by a Vickers indentation near and far the interface with the zirconia shows that the stress profiles are different.

  3. Porcelain-coated antenna for radio-frequency driven plasma source

    DOEpatents

    Leung, K.N.; Wells, R.P.; Craven, G.E.

    1996-12-24

    A new porcelain-enamel coated antenna creates a clean plasma for volume or surface-conversion ion sources. The porcelain-enamel coating is hard, electrically insulating, long lasting, non fragile, and resistant to puncture by high energy ions in the plasma. Plasma and ion production using the porcelain enamel coated antenna is uncontaminated with filament or extraneous metal ions because the porcelain does not evaporate and is not sputtered into the plasma during operation. Ion beams produced using the new porcelain-enamel coated antenna are useful in ion implantation, high energy accelerators, negative, positive, or neutral beam applications, fusion, and treatment of chemical or radioactive waste for disposal. For ion implantation, the appropriate species ion beam generated with the inventive antenna will penetrate large or small, irregularly shaped conducting objects with a narrow implantation profile. 8 figs.

  4. Effect of laser parameters on the microstructure of bonding porcelain layer fused on titanium

    NASA Astrophysics Data System (ADS)

    Chen, Xiaoyuan; Guo, Litong; Liu, Xuemei; Feng, Wei; Li, Baoe; Tao, Xueyu; Qiang, Yinghuai

    2017-09-01

    Bonding porcelain layer was fused on Ti surface by laser cladding process using a 400 W pulse CO2 laser. The specimens were studied by field-emission scanning electron microscopy, X-ray diffraction and bonding tests. During the laser fusion process, the porcelain powders were heated by laser energy and melted on Ti to form a chemical bond with the substrate. When the laser scanning speed decreased, the sintering temperature and the extent of the oxidation of Ti surface increased accordingly. When the laser scanning speed is 12.5 mm/s, the bonding porcelain layers were still incomplete sintered and there were some micro-cracks in the porcelain. When the laser scanning speed decreased to 7.5 mm/s, vitrified bonding porcelain layers with few pores were synthesized on Ti.

  5. Effect of thermal tempering on strength and crack propagation behavior of feldspathic porcelains.

    PubMed

    Anusavice, K J; Hojjatie, B

    1991-06-01

    The objective of this study was to test the hypothesis that tempering stress can retard the growth of surface cracks in layered porcelain discs with variable levels of contraction mismatch. Porcelain discs, 16 mm in diameter and 2 mm thick, were prepared with a 0.5-mm-thick layer of opaque porcelain (O) and a 1.5-mm-thick layer of body porcelain (B). The materials were selected to produce contraction coefficient differences, alpha O-alpha B, of +3.2, +0.7, -0.9, and -1.5 ppm/degrees C. Body porcelain discs with a thickness of 2 mm were used as the thermally compatible control specimens (delta alpha = 0). The discs were fired to the maturing temperature of body porcelain (982 degrees C) and were then subjected to three cooling procedures: slow cooling (SC) in a furnace, fast cooling (FC) in air, and tempering (T) by blasting the surface of the body porcelain with compressed and dried air for 90 s. The dimensions of cracks induced by a Vickers microhardness indenter under a load of 4.9 N were measured at baseline and six months after indentation at 80 points along diametral lines within the surface of body porcelain. In addition, biaxial flexure tests were performed to determine the influence of mismatch and tempering on flexure strength. The results of ANOVA indicate that crack dimensions were influenced significantly by the interaction of cooling rate and contraction mismatch (p less than 0.0001).(ABSTRACT TRUNCATED AT 250 WORDS)

  6. [The influence of surface conditioning on the shear bond strength of La-Porcelain and titanium].

    PubMed

    Mo, Anchun; Cen, Yuankun; Liao, Yunmao

    2003-04-20

    To determine the influence of different surface conditioning methods on bonding strength of low fusing porcelain (La-Porcelain) and titanium. The surface of the samples were sandblasted for 2 min with 80-250 microns Al2O3 or coated for two times with Si-couple agent or conditioned by pre-oxidation. The shear bond strength was examined by push-type shear test with a speed of 0.5 mm/min in a universal testing machine. Scanning electron microscopy (SEM) and electron probe micro-analyzer (EPMA) were employed to explore the relationship between bonding strength and microstructures, as well as the element diffusion at the interface between porcelain coating and titanium when heated at 800 degrees C. Bonding strength was not statistically different (P > 0.05) after sandblasting with Al2O3 in particle size ranged from 80 microns to 250 microns. When a Si-couple agent was used, bond of porcelain to titanium was significantly lower (P < 0.05). The shear bond strength of the porcelain to the pre-oxidized titanium surface remained unchanged after heating (P > 0.05). The SEM results revealed integrity of porcelain and titanium. La-Porcelain showed a small effect of surface coarseness. Sandblasting the titanium surface with 150-180 microns Al2O3 can be recommended as a method for better bonding between La-Porcelain and titanium. The Si-couple agent coating and pre-oxidation of titanium surface is unnecessary.

  7. [Interface bond and compatibility between GI-II glass/alumina composite and Vitadur alpha veneering porcelain].

    PubMed

    Meng, Yukun; Chao, Yonglie; Liao, Yunmao

    2002-01-01

    Multiple layer techniques were commonly employed in fabricating all-ceramic restorations. Bond and compatibility between layers were vitally important for the clinical success of the restorations. The purposes of this study were to investigate the bond of the interface between the GI-II glass/alumina composite and Vitadur alpha veneering porcelain, and to study the thermal compatibility between them. Prepared a bar shaped specimen of GI-II glass/alumina composite 25 mm x 5 mm x 1 mm in size, with bottom surface pre-notched. The upper surface was veneered with Vitadur alpha veneering porcelain (0.2 mm opaque dentin and 0.6 mm dentin porcelain), then fractured and the fracture surface were examined under scanning electron microscope (SEM) and electron microprobe analyzer (EMPA) with electron beam of 10 micrometer in diameter; ten all-ceramic single crowns for an upper right central incisor were fabricated and the temperatures of thermal shock resistance were tested. SEM observation showed tight bond between the composite and the porcelain; The results of EMPA showed that penetration of Na, Al elements from glass/alumina into veneering porcelain and Si, K, Ca elements from veneering porcelain into glass/alumina occurred after sintering baking; The temperature of thermal shock resistance for anterior crowns in this study was 158 +/- 10.3 degrees C, cracks were mainly distributed in veneering porcelain with thicker layer. Chemical bond exists between the GI-II glass/alumina composite and Vitadur alpha veneering porcelain, and there is good thermal compatibility between them.

  8. [Effect of vacuum deposition technology on the metal-porcelain bond strength of a new type of CO-CR ceramic and framework dental alloy].

    PubMed

    Wu, Jun-ling; Chao, Yong-lie; Ji, Ping; Gao, Xu

    2007-10-01

    To investigate the effect of a new engineering technique of vacuum deposition-plasma magnetron reactive sputter deposition technique on the metal-porcelain bond strength of a new type of Co-Cr ceramic and framework dental alloy. Before porcelain painted on the specimens, the standardized metal strips made from DA9-4 dental alloy were coated with a thin Al2O3 ceramic film by plasma magnetron reactive sputter deposition technique. The conformation, structure and thickness of the ceramic film were analyzed. The specimens for three-point bending test made from DA9-4 alloy and VMK95 porcelain were used for metal-porcelain bond strength measurement, in the same time the interface of metal-porcelain and element distribution were also observed. The flexural bonding strength of metal-porcelain of sputtering group and control group were (180.55+/-16.45) MPa and (143.80+/-24.49) MPa. The flexural bonding strength of metal-porcelain of sputtering group was higher than control group significantly through statistical analysis (P<0.01). The plasma magnetron reactive sputter deposition technique has a positive effect in improving the bonding strength of DA9-4 dental alloy and ceramic.

  9. Porcelain-metal bonding: part I. Effects of repeated baking process.

    PubMed

    Nagasawa, S; Yoshida, T; Mizoguchi, H; Ito, M; Oshida, Y

    2001-01-01

    A plurality of repeated porcelain-baking procedures are normally practiced in order to achieve the final adjustment metal-porcelain restorations. By increasing the number of baking cycles, the undesired internal strain would be built-up, causing the reduction of mechanical properties and deterioration of color characteristics. However the extensive studies on such deterioration have not been done. In this study, effects of numbers (up to 10 times) of repeated baking cycles on baking shrinkage, surface roughness, bend strength, color changes and internal microstructure were investigated when opaque, body and enamel was individually applied or when a triple-player comprising of these three porcelains was repeatedly applied. It was concluded that (1) the bend strengths increased by increasing baking cycles, (2) the average surface roughness decreased by increasing number of baking procedures, (3) changes in color characteristics was very small in the Vintage halo porcelain system, and (4) since the pores entrapped in the porcelain remained even by increasing baking cycles, it is recommended to remove the surface pores before forming the next layer when handling the high viscous opaque porcelain.

  10. [Measurement and comparison of the spectral transmittance of cerinate porcelain and human enamel].

    PubMed

    Chen, Ji-Hua; Zhou, Guo-Feng; Wei, Zhang-Rui; Wang, Hui; Zhao, San-Jun

    2006-12-01

    To measure the spectral transmittance of Cerinate porcelain veneer and enamel in different color and different thickness. Samples of Cerinate porcelain veneers were prepared in different thickness (0.50 mm, 0.75 mm, 1.00 mm) and different Vita shade (A1, A2, A3). Enamel samples in shade A2 were made with three thickness (0.50 mm, 0.75 mm, 1.00 mm). A spectrophotometer with spectra range (380-800 nm) was employed to measure the spectral transmittance. Spectral transmittance decreased with the increasing in the thickness of specimens and decreasing in the color darkness. The transmittance of Cerinate porcelain veneer material and enamel in the same color and same thickness hadn't significant difference. The key factor to spectral transmittance of porcelain veneer materials is veneer's thickness, and the color of the materials has also some influence on it. Cerinate porcelain veneers can properly recover the transparency of teeth.

  11. [The fabrication and chroma study of a kind of custom shade guide with metal substrate].

    PubMed

    Chen, Ling; Liu, Xian; Xu, Li-qiang; Chao, Yong-lie; Liu, Wen-fang; Chen, Xiao-fang

    2007-06-01

    This study was to explore the chroma of a custom shade guide with metal substrate. A custom shade guide sample was fabricated using the central maxillary incisor as a model,which was corresponding to the colour of VITAPAN shade guide.The colour of each shade tab was measured with PR-650 spectrophotometer when every porcelain was added. From the opaque to glaze, the lightness was decreased and the chroma was increased distinctively; When the body porcelain were baked over their corresponding opaque, the lightness was decreased and the chroma was increased; When the enamel porcelain and the translucent porcelain were added on, the lightness and chroma were decreased slightly; the glaze could increase the lightness. The "add on" porcelain can affect the final color of the restoration, and the effects of each porcelain layer were different from each other.

  12. Kubelka-Munk reflectance theory applied to porcelain veneer systems using a colorimeter.

    PubMed

    Davis, B K; Johnston, W M; Saba, R F

    1994-01-01

    The purpose of this study was to demonstrate the ability of Kubelka-Munk reflectance theory to predict color parameters of veneer porcelain on various backings using colorimetric measurements. Tristimulus absorption and scattering coefficients were used to predict the respective tristimulus reflectance values of A1, D3, and translucent porcelain samples after they had been bonded to light and dark substrates using universal, opaque, and untinted shades of bonding resin. Observed and predicted reflectance values exhibited high correlation (r2 > or = 0.93 for each porcelain shade). Kubelka-Munk theory offers an accurate prediction for the resultant colorimetric reflectance parameters of veneer porcelain bonded to variously colored backings.

  13. Non-Gold Base Dental Casting Alloys. Volume 2. Porcelain-Fused-to-Metal Alloys.

    DTIC Science & Technology

    1986-08-01

    of the tooth . At the same time, enamel porcelains can be applied from the incisal one-third, through the middle one-third, and be subtly blended into...alumina (aluminum oxide) in a glass matrix. 1 Natural tooth color and opacification are obtained by the addition of metallic oxides to the porcelain...are classified as opaque, dentin (or body), and enamel (or incisal) porcelain powders with numerous color concentrates, such s opaque and dentin color

  14. Temperature changes across porcelain during multiple exposure CO2 lasing

    NASA Astrophysics Data System (ADS)

    Barron, Joseph R.; Zakariasen, Kenneth L.; Peacocke, Larry

    1990-06-01

    Research indicates that laser energy may provide a useful method for glazing and fusing porcelain for intraoral prosthetic purposes. However, it is not known whether such lasing will result in the production of heat levels that may be damaging to adjacent vital tissues such as the dental pulp and periodontal tissues. This research is designed to measure the magnitude of temperature rise across porcelain observed during multiple exposure C02 lasing. Fifteen porcelain examples of 1000 jim (5), 1500 pm (5) and 2000 tm (5) x each received five C02 laser exposures on the same exposure site at 1.0 sec. intervals at 8.0 watts (0.2 sec. per exposure with a 1 mm focal spot). A YSI 144201 thermilinear precision thermistor was placed on the porcelain surface opposite each laser exposure site. Temperature rise above ambient was recorded by an HP3421A data acquisition unit and HP9816 technical microcomputer. Recording continued for sufficient time to allow temperatures to return to ambient. The mean temperature elevations ranged from a low of 2.97 0C (2000 pm) to a high of 7.77 °C (1000 μm). ANOVA and Duncan's Multiple Range Test indicated significant differences in temperature rise by porcelain thickness. It would appear from the results of this research that temperature elevations adjacent to lased porcelain may be sufficiently controllable that safe intraoral porcelain lasing will be possible.

  15. [Effect of sintering gold paste coating on the bonding strength of pure titanium and three low-fusing porcelains].

    PubMed

    Zhang, Ya-li; Luo, Xiao-ping; Zhou, Li

    2012-05-01

    To study the effect of sintering gold paste coating of pure titanium on the adhesion of three porcelains following the protocol ISO 9693, and to investigate the titanium-porcelains interfaces. Sixty machined pure titanium samples were prepared in a rectangular shape according to ISO 9693 and divided equally into six groups. Half of the strips were coated with gold paste (Deckgold) and sintered. Three ultra-low-fusing dental porcelains (I: Initial Ti, S: Super porcelain Ti-22, T: TitanKeramik) were fused onto the titanium surfaces. A thin layer of bonding agent was only applied on the surfaces of uncoated gold specimens. The interface of the porcelain and titanium was observed with a field emission scanning electron microscope (FE-SEM) after metallographic preparation and sputtered with a very thin carbon layer of the embedded titanium-porcelain interface. After three-point bending test was performed, optical stereomicroscope was used to characterize the titanium-porcelains adhesion and determine the mode of failure. FE-SEM illustrated intermetallic compounds of Au-Ti formed with some visible microcracks in the gold layer and the interface of gold layer and ceramic. All the uncoated gold titanium-porcelain system showed predominately adhesive fracture at the titanium oxidation, whereas the failure modes in all gold coated systems were cohesive and adhesive, mainly cohesive. The three-point-bending test showed that the bonding strength of GS and GI groups [(37.08 ± 4.32) and (36.20 ± 2.40) MPa] were higher than those in uncoated groups [(31.56 ± 3.74) and (30.88 ± 2.60) MPa, P < 0.05], while no significant difference was found between T group and GT group (P > 0.05). The gold paste intermediate coatings can improve bond strengths of Super porcelain Ti-22 system and Initial Ti system, which have potential applications in clinical fields.

  16. The bending stress distribution in bilayered and graded zirconia-based dental ceramics

    PubMed Central

    Fabris, Douglas; Souza, Júlio C.M.; Silva, Filipe S.; Fredel, Márcio; Mesquita-Guimarães, Joana; Zhang, Yu; Henriques, Bruno

    2016-01-01

    The purpose of this study was to evaluate the biaxial flexural stresses in classic bilayered and in graded zirconia-feldspathic porcelain composites. A finite element method and an analytical model were used to simulate the piston-on-ring test and to predict the biaxial stress distributions across the thickness of the bilayer and graded zirconia-feldspathic porcelain discs. An axisymmetric model and a flexure formula of Hsueh et al. were used in the FEM and analytical analysis, respectively. Four porcelain thicknesses were tested in the bilayered discs. In graded discs, continuous and stepwise transitions from the bottom zirconia layer to the top porcelain layer were studied. The resulting stresses across the thickness, measured along the central axis of the disc, for the bilayered and graded discs were compared. In bilayered discs, the maximum tensile stress decreased while the stress mismatch (at the interface) increased with the porcelain layer thickness. The optimized balance between both variables is achieved for a porcelain thickness ratio in the range of 0.30–0.35. In graded discs, the highest tensile stresses were registered for porcelain rich interlayers (p=0.25) whereas the zirconia rich ones (p=8) yield the lowest tensile stresses. In addition, the maximum stresses in a graded structure can be tailored by altering compositional gradients. A decrease in maximum stresses with increasing values of p (a scaling exponent in the power law function) was observed. Our findings showed a good agreement between the analytical and simulated models, particularly in the tensile region of the disc. Graded zirconia-feldspathic porcelain composites exhibited a more favourable stress distribution relative to conventional bilayered systems. This fact can significantly impact the clinical performance of zirconia-feldspathic porcelain prostheses, namely reducing the fracture incidence of zirconia and the chipping and delamination of porcelain. PMID:28104926

  17. [Study on content of nickel in saliva released from the nickel-chromium and the nickel-chromium-titanium porcelain alloy].

    PubMed

    Wang, Wen-Jie; Zhang, Tai-Qiang; Wei, Hong

    2010-02-01

    The purpose of the study was to investigate the content of nickel (Ni) ion in patients' saliva after wearing the porcelain-fused-to nickel-chromium (Ni-Cr) crown or the porcelain-fused-to nickel-chromium-titanium(Ni-Cr-Ti) crown. 50 patients who had one molar or premolar needed repairing were selected and divided into two groups randomly. Patients in one group were fabricated with porcelain-fused-to Ni-Cr crown and the patients in the other group were fabricated with porcelain-fused-to Ni-Cr-Ti crown. Collect the patients' saliva before wearing, 1 week, 3 months, and 6 months after wearing. The content of Ni ion in saliva was detected by inductively coupled plasma mass spectrometry (ICP-MS). The content of Ni ion in both groups increased at the first week, and go back after 6 months. There were no significant differences before wearing, 1 week, 3 months, and 6 months after wearing. There were no significant differences between the two groups. Wearing the porcelain-fused-to Ni-Cr crown or the porcelain-fused-to Ni-Cr-Ti crown has no significant influence on the content of Ni ion in saliva.

  18. The Billingsley Dairy: A Family Enterprise in the Prado Basin. CA-RIV- 3508-H

    DTIC Science & Technology

    1990-06-01

    Porcelain Products, Inc. was formed in July 1927 with the merging of six porcelain insulator companies; "Alligator" was a trade name used on their split...knob insulators (Tod 1977:91-93). Standard porcelain wall tubes were also present; they normally go hand-in-hand with split or solid nail or screw...basin. Fragments of a porcelain toilet fixture were found scattered on and near this slab, which apparently served only as a toilet and washing facility

  19. Analysis of Archaeological, Geological and Historical Artifacts and Documents Pertaining to the Midden Excavation at ’Woodville’ - Unit 4, James G. Fulton, Flood Protection Project, Chartiers Creek, Pennsylvania,

    DTIC Science & Technology

    1985-03-01

    104 INTRODUCTION TO ANALYZED CERAMICS by John Eddins ....................... 128 DECORATED PORCELAIN by Noel Strattan Introduction...vessel terminology 135 DECORATED PORCELAIN Figure 1. Photographs of selected porcelain patterns 200-14 between 201 - 448 i. WHITEWARE AND SEMI-VITREOUS...Potential date curves by count for Features 20, 21, 885 and 25 Figure 3. Weighted potential date curves for ceramics 8896 ( porcelain , whiteware, and semi

  20. Effects of porcelain thickness on the flexural strength and crack propagation in a bilayered zirconia system

    PubMed Central

    de Figueiredo, Viviane Maria Gonçalves; Pereira, Sarina Maciel Braga; Bressiani, Eduardo; Valera, Márcia Carneiro; Bottino, Marco Antônio; Zhang, Yu; de Melo, Renata Marques

    2017-01-01

    Abstract Objective: This study evaluated the influence of porcelain (VM9, VITA Zahnfabrik, Germany) thickness on the flexural strength and crack propagation in bilayered zirconia systems (YZ, VITA Zahnfabrik, Germany). Material and Methods: Thirty zirconia bars (20.0x4.0x1.0 mm) and six zirconia blocks (12.0x7.5x1.2 mm) were prepared and veneered with porcelain with different thickness: 1 mm, 2 mm, or 3 mm. The bars of each experimental group (n=10) were subjected to four-point flexural strength testing. In each ceramic block, a Vickers indentation was created under a load of 10 kgf for 10 seconds, for the propagation of cracks. Results: The results of flexural strength were evaluated by One-way ANOVA and Tukey's test, with a significance level of 5%. The factor “thickness of the porcelain” was statistically significant (p=0.001) and the l-mm group presented the highest values of flexural strength. The cracks were predominant among the bending specimens with 1 and 2 mm of porcelain, and catastrophic failures were found in 50% of 3-mm-thick porcelain. After the indentation of blocks, the most severe defects were observed in blocks with 3-mm-thick porcelain. Conclusion: The smallest (1 mm) thickness of porcelain on the zirconia infrastructure presented higher values of flexural strength. Better resistance to defect propagation was observed near the porcelain/ zirconia interface for all groups. Higher flexural strength was found for a thinner porcelain layer in a bilayered zirconia system. The damage caused by a Vickers indentation near and far the interface with the zirconia shows that the stress profiles are different. PMID:29069155

  1. Comparison of the microstructure and phase stability of as-cast, CAD/CAM and powder metallurgy manufactured Co-Cr dental alloys.

    PubMed

    Li, Kai Chun; Prior, David J; Waddell, J Neil; Swain, Michael V

    2015-12-01

    The objective of this study was to identify the different microstructures produced by CC, PM and as-cast techniques for Co-Cr alloys and their phase stability following porcelain firings. Three bi-layer porcelain veneered Co-Cr specimens and one monolithic Co-Cr specimen of each alloy group [cast, powder metallurgy (PM), CAD/CAM (CC)] were manufactured and analyzed using electron backscatter diffraction (EBSD), energy dispersive spectrometry (EDS) and X-ray diffraction (XRD). Specimens were treated to incremental numbers of porcelain firings (control 0, 5, 15) with crystallographic data, grain size and chemical composition subsequently obtained and analyzed. EBSD datasets of the cast alloy indicated large grains >200 μm whereas PM and CC alloy consisted of mean arithmetic grain sizes of 29.6 μm and 19.2 μm respectively. XRD and EBSD results both indicated the highest increase in hcp content (>13vol%) for cast Co-Cr alloy after treatment with porcelain firing while PM and CC indicated <2vol% hcp content. A fine grain interfacial layer developed on all surfaces of the alloy after porcelain firing. The depth of this layer increased with porcelain firings for as-cast and PM but no significant increase (p>.05) was observed in CC. EDS line scans indicated an increase in Cr content at the alloy surface after porcelain firing treatment for all three alloys. PM and CC produced alloy had superior fcc phase stability after porcelain firings compared to a traditional cast alloy. It is recommended that PM and CC alloys be used for porcelain-fused-to-metal restorations. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  2. 49 CFR 178.523 - Standards for composite packagings with inner glass, porcelain, or stoneware receptacles.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... glass, porcelain, or stoneware receptacles. 178.523 Section 178.523 Transportation Other Regulations... Standards § 178.523 Standards for composite packagings with inner glass, porcelain, or stoneware receptacles. (a) The following are identification codes for composite packagings with inner receptacles of glass...

  3. 76 FR 2920 - Porcelain-on-Steel Cooking Ware From China

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-18

    ... Cooking Ware From China AGENCY: United States International Trade Commission. ACTION: Scheduling of an expedited five-year review concerning the antidumping duty order on porcelain-on-steel cooking ware from... revocation of the antidumping duty order on porcelain-on-steel cooking ware from China would be likely to...

  4. PIXE study on the provenance of Chinese ancient porcelain

    NASA Astrophysics Data System (ADS)

    Zhu, D.; Cheng, H. S.; Lin, J. W.; Yang, F. J.

    2006-08-01

    This paper reports the PIXE study on the provenance of Chinese ancient porcelain made in 7-10th century. The chemical compositions of Jun celadon samples made at Juntai, Linru and Hunyuan kilns, the white-glazed porcelain samples made at Ding, Huangye and Dangyangyu kilns, and the Ru celadon samples made at Qiangliang Temple were measured by external-beam PIXE, and the factor analysis was applied for identifying their provenances. Experimental results show that the porcelain products made at different kilns can be distinguished according to the compositional differences measured by PIXE.

  5. PIXE analysis of Chinese ancient greenish white porcelain

    NASA Astrophysics Data System (ADS)

    Cheng, Lin; Ding, Xun-liang; Feng, Song-lin; Cheng, Huang-sheng; Zhang, Wen-Jiang; Fan, Chang-Sheng

    2006-03-01

    This paper reports the results about the PIXE analysis of major, minor and trace elements of Chinese ancient greenish white porcelain and blue-and-white porcelain produced in Hutian Kiln (Jingdezhen district, Jiangxi province) during 10th-14th centuries. The porcelain body and greenish white glaze from northern Song (AD 960), southern Song (AD 1037-1276), early Yuan (AD 1279-1320), later Yuan (AD 1320-1368) were investigated together with white-and-blue glaze from Ming dynasty (AD 1368-1644). The obtained data were further analyzed by factor analysis.

  6. [Research progress of bonding strength between porcelain veneer and enamel].

    PubMed

    Cheng, Hong; Zhang, Fu-qiang

    2014-02-01

    Porcelain veneer had gained more and more attention in dental clinical applications due to its advantages such as good esthetic effects and minor invasiveness. The reliable and consistent adhesive bonding were the key to success. The enamel which featured high mineralization and low moisture would be the ideal bonding part for porcelain veneer. This article was aimed to summarize the research progress regarding to those factors that might had effect on the bonding strength between the porcelain veneer and the enamel including the restoration types of resin adhesives and bonding surface preparations.

  7. Provenance study of ancient Chinese Yaozhou porcelain by neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Li, G. X.; Y Gao, Z.; Li, R. W.; Zhao, W. J.; Xie, J. Z.; Feng, S. L.; Zhuo, Z. X.; Y Fan, D.; Zhang, Y.; Cai, Z. F.; Liu, H.

    2003-09-01

    This paper reports our study of the provenance of ancient Chinese Yaozhou porcelain. The content of 29 elements in the Yaozhou porcelain samples was measured by neutron activation analysis (NAA). The NAA data were further analysed using fuzzy cluster analysis to obtain the trend fuzzy cluster diagrams. These samples with different glaze colour, ranging over more than 700 years, were fired in different kilns. Our analysis indicates the relatively concentrated distribution of the sources of the raw material for the Yaozhou porcelain body samples. They can be classified into two independent periods, i.e. the Tang (AD 618-907) and the Five Dynasties (AD 907-960) period, and the Song (AD 960-1279) and Jin (AD 1115-1234) period. Our analysis also indicates that the sources of the raw material for the ancient Yaozhou porcelain glaze samples are quite scattered and those for the black glaze in the Tang Dynasty are very concentrated. The sources of the raw material for the celadon glaze and the white glaze in the Tang Dynasty are widely distributed and those for the celadon glaze in the Song Dynasty are close to those of the bluish white glaze in the Jin Dynasty, and they are very concentrated. The sources of the raw material for the porcelain glazes cover those of the porcelain bodies.

  8. Cracking of porcelain surfaces arising from abrasive grinding with a dental air turbine.

    PubMed

    Chang, Chee W; Waddell, J Neil; Lyons, Karl M; Swain, Michael V

    2011-12-01

    The purpose of this in vitro study was to evaluate porcelain cracking induced by abrasive grinding with a conventional dental air turbine and abrasive diamond burs. Four commercially available porcelains were examined-Wieland ALLUX, Wieland ZIROX, IPS e.max Ceram, and IPS Empress Esthetic Veneering porcelain. Sixty discs of each porcelain type were fabricated according to manufacturer instructions, followed by an auto-glaze cycle. Abrasive grinding using fine, extra-fine, and ultra-fine diamond burs was carried out, using a conventional dental air turbine. The grinding parameters were standardized with regard to the magnitude of the force applied, rotational speed of the diamond bur, and flow rate of the water coolant. A testing apparatus was used to control the magnitude of force applied during the grinding procedure. The ground surfaces were then examined under scanning electron microscope. Cracking was seen for all porcelain types when ground with the fine bur. Cracking was not seen for specimens ground with the extra-fine or the ultra-fine bur. Wet abrasive grinding with a conventional dental air turbine and fine grit diamond burs has the potential to cause cracking in the four porcelain types tested. Similar abrasive grinding with smaller grit size particles does not cause similar observable cracking. © 2011 by the American College of Prosthodontists.

  9. Porcelain monolayers and porcelain/alumina bilayers reinforced by Al2O3/GdAlO3 fibers.

    PubMed

    Sgura, Ricardo; Medeiros, Igor Studart; Cesar, Paulo Francisco; Campos, Adeliani Almeida; Hernandes, Antonio Carlos

    2012-01-01

    This work tested the effect of the addition of Al(2)O(3)/GdAlO(3) longitudinal fibers in different contents to veneering porcelain of two dental all ceramic systems. Fibers (0.5 mm diameter) obtained by the Laser Heated Pedestal Growth (LHPG) method were added to bar-shaped specimens made by veneer porcelain (monolayers) or both the veneer and the core ceramic (bilayers) of two all-ceramic systems: In-Ceram Alumina-glass infiltrated alumina composite (GIA) and In-Ceram 2000 AL Cubes-alumina polycrystal (AP) (VITA Zahnfabrik). The longitudinal fibers were added to veneering porcelain (VM7) in two different proportions: 10 or 17 vol%. The bars were divided into nine experimental conditions (n=10) according to material used: VM7 porcelain monolayers, VM7/GIA, VM7/AP; and according to the amount of fibers within the porcelain layer: no fibers, 10 vol% or 17 vol%. After grinding and polishing the specimens were submitted to a three point bending test (crosshead speed = 0.5 mm/min) with porcelain positioned at tensile side. Data were analyzed by means of one-way ANOVA and a Tukey's test (α=5%). Scanning electronic microscopy (SEM) was conducted for fractographic analysis. Regarding the groups without fiber addition, VM7/AP showed the highest flexural strength (MPa), followed by VM7/GIA and VM7 monolayers. The addition of fibers led to a numerical increase in flexural strength for all groups. For VM7/GIA bilayers the addition of 17 vol% of fibers resulted in a significant 48% increase in the flexural strength compared to the control group. Fractographic analysis revealed that the crack initiation site was in porcelain at the tensile surface. Cracks also propagated between fibers before heading for the alumina core. The addition of 17 vol% of Al(2)O(3)/GdAlO(3) longitudinal fibers to porcelain/glass infiltrated alumina bilayers significantly improved its flexural strength. 10 vol% or 17 vol% of fibers inclusion increased the flexural strength for all groups. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Effect of cooling rate on leucite volume fraction in dental porcelains.

    PubMed

    Mackert, J R; Evans, A L

    1991-02-01

    Prasad et al. (1988) have shown that slow cooling of dental porcelain produces increases in thermal expansion sufficient to make a compatible metal-porcelain system incompatible. The present study was undertaken to determine whether the increase in porcelain thermal expansion might be attributable to crystallization of additional leucite during slow cooling of the porcelain. Eight x-ray diffraction specimens for each of six commercial dental porcelains and for the Component No. 1 frit of the Weinstein and Weinstein (1962) and Weinstein et al. (1962) patents were fabricated and divided into two groups. Specimens in the first group (termed fast-cooled) were cooled in the conventional manner by removing them from the furnace at the maximum firing temperature immediately into room air. Specimens in the second group (termed slow-cooled) were cooled slowly by interrupting power to the furnace muffle and allowing them to cool inside the closed furnace. Quantitative x-ray diffraction was performed on the fast- and slow-cooled porcelain specimens with standards containing leucite volume fractions of 0.111, 0.223, 0.334, and 0.445. Unpaired, one-tailed t tests were performed on the fast- and slow-cool data, and a significant increase (p less than 0.05) in the amount of leucite (as a function of the slow cooling) was found for each of the porcelains. The increases in the leucite volume fractions resulting from the slow cooling ranged from a low of 8.5% to a high of 55.8%, with an average increase of 26.9%.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. 76 FR 13602 - Porcelain-on-Steel Cooking Ware From the People's Republic of China: Continuation of Antidumping...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-14

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-506] Porcelain-on-Steel Cooking... cooking ware (``POS cookware'') from the People's Republic of China (``PRC'') would likely lead to a... should the order be revoked. See Porcelain-on-Steel Cooking Ware from the People's Republic of China...

  12. [Evaluation of labial surface root filling combined with porcelain dental restoration].

    PubMed

    Liu, Yuan-qiao; Huang, Zhi-hua; Hu, Huan-yu

    2015-04-01

    To analyze the effect of porcelain dental restoration combined with labial surface root filling for the anterior teeth. One hundred cases with anterior teeth protrusion treated in our department from January 2010 to January 2014 underwent porcelain dental restoration combined with labial surface root filling. The measurements in cephalometric X-ray films before and after treatment were compared, and porcelain dental appearance and function were evaluated. The data was statistically analyzed with SPSS18.0 software package. After treatment, U1-SN, U1-X, U1-Y were significantly lower than before treatment (P<0.01). U1-L1 was significantly higher after treatment (P<0.01). The incidence of gingivitis after treatment decreased significantly (X(2)=16.2749,P=0.0000<0.01). The excellent rate of outline of porcelain teeth after treatment, correction of protruding anterior teeth, fitting with adjacent teeth and alleviation of deep overbite and deep cover was 96.00%, 95.00%, 98.00% and 91.00%, respectively. Porcelain dental restoration after root canal treatment can effectively improve anterior teeth protrusion and increase the aesthetic appearance, which is worthy of clinical application.

  13. Evaluation of Different Types of Lasers in Surface Conditioning of Porcelains: A Review Article

    PubMed Central

    Mirhashemi, Amirhossin; Sharifi, Nastaran; Moharrami, Mohammad; Chiniforush, Nasim

    2017-01-01

    To achieve proper bond strength for porcelains, adequate surface roughness is essential, which is traditionally gained by sandblasting or acid etching with hydrofluoric (HF) acid. Nowadays with the development of laser systems, serious efforts were made to apply this new instrument for surface etching of porcelains due to easy usage, safety, and more efficiency. There are different kinds of lasers and porcelains, so choosing the ones which will be good match for each other is crucial. Besides that, changing the irradiation setting can be beneficial as well. This article reviewed 33 related studies and summarized results of etching accomplished by Nd:YAG, Er:YAG, Er,Cr:YSGG and CO2 lasers on different types of porcelains considering different laser settings and evaluation methods to bring a comprehensive insight. PMID:29123628

  14. [Line scanning analysis of white porcelain from Gong Kiln in early Tang dynasty by energy disperse X-ray fluorescence].

    PubMed

    Ling, Xue; Mao, Zhen-wei; Feng, Min; Hu, Yao-wu; Wang, Chang-sui; Liu, Hong-miao

    2005-07-01

    Gong kiln, for its long porcelain-firing history, was one of three representative white porcelain kilns in northern China. In order to improve the quality and whiteness of white porcelain, a decorating layer or cosmetic earth was laid on the body surface in Gong kiln during early Tang dynasty, which was able to blot out rough surface and weaken the influence of fuscous body upon surface color. In this paper the main chemical composition of the white porcelain's profile was analyzed by using energy disperse X-Ray fluorescence. The result showed that different materials were used as cosmetic earth during early Tang dynasty, in accordance with the phenomenon under optical microscope. In addition, the glaze belongs to calcium glaze in which plant ash was added.

  15. Influence of the processing route of porcelain/Ti-6Al-4V interfaces on shear bond strength.

    PubMed

    Toptan, Fatih; Alves, Alexandra C; Henriques, Bruno; Souza, Júlio C M; Coelho, Rui; Silva, Filipe S; Rocha, Luís A; Ariza, Edith

    2013-04-01

    This study aims at evaluating the two-fold effect of initial surface conditions and dental porcelain-to-Ti-6Al-4V alloy joining processing route on the shear bond strength. Porcelain-to-Ti-6Al-4V samples were processed by conventional furnace firing (porcelain-fused-to-metal) and hot pressing. Prior to the processing, Ti-6Al-4V cylinders were prepared by three different surface treatments: polishing, alumina or silica blasting. Within the firing process, polished and alumina blasted samples were subjected to two different cooling rates: air cooling and a slower cooling rate (65°C/min). Metal/porcelain bond strength was evaluated by shear bond test. The data were analyzed using one-way ANOVA followed by Tuckey's test (p<0.05). Before and after shear bond tests, metallic surfaces and metal/ceramic interfaces were examined by Field Emission Gun Scanning Electron Microscope (FEG-SEM) equipped with Energy Dispersive X-Ray Spectroscopy (EDS). Shear bond strength values of the porcelain-to-Ti-6Al-4V alloy interfaces ranged from 27.1±8.9MPa for porcelain fused to polished samples up to 134.0±43.4MPa for porcelain fused to alumina blasted samples. According to the statistical analysis, no significant difference were found on the shear bond strength values for different cooling rates. Processing method was statistically significant only for the polished samples, and airborne particle abrasion was statistically significant only for the fired samples. The type of the blasting material did not cause a statistically significant difference on the shear bond strength values. Shear bond strength of dental porcelain to Ti-6Al-4V alloys can be significantly improved from controlled conditions of surface treatments and processing methods. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Shear bond strength of veneering porcelain to zirconia: Effect of surface treatment by CNC-milling and composite layer deposition on zirconia.

    PubMed

    Santos, R L P; Silva, F S; Nascimento, R M; Souza, J C M; Motta, F V; Carvalho, O; Henriques, B

    2016-07-01

    The purpose of this study was to evaluate the shear bond strength of veneering feldspathic porcelain to zirconia substrates modified by CNC-milling process or by coating zirconia with a composite interlayer. Four types of zirconia-porcelain interface configurations were tested: RZ - porcelain bonded to rough zirconia substrate (n=16); PZ - porcelain bonded to zirconia substrate with surface holes (n=16); RZI - application of a composite interlayer between the veneering porcelain and the rough zirconia substrate (n=16); PZI - application of a composite interlayer between the porcelain and the zirconia substrate treated by CNC-milling (n=16). The composite interlayer was composed of zirconia particles reinforced porcelain (30%, vol%). The mechanical properties of the ceramic composite have been determined. The shear bond strength test was performed at 0.5mm/min using a universal testing machine. The interfaces of fractured and untested specimens were examined by FEG-SEM/EDS. Data was analyzed with Shapiro-Wilk test to test the assumption of normality. The one-way ANOVA followed by Tukey HSD multiple comparison test was used to compare shear bond strength results (α=0.05). The shear bond strength of PZ (100±15MPa) and RZI (96±11MPa) specimens were higher than that recorded for RZ (control group) specimens (89±15MPa), although not significantly (p>0.05). The highest shear bond strength values were recorded for PZI specimens (138±19MPa), yielding a significant improvement of 55% relative to RZ specimens (p<0.05). This study shows that it is possible to highly enhance the zirconia-porcelain bond strength - even by ~55% - by combining surface holes in zirconia frameworks and the application of a proper ceramic composite interlayer. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Shear bond strength between an indirect composite layering material and feldspathic porcelain-coated zirconia ceramics.

    PubMed

    Fushiki, Ryosuke; Komine, Futoshi; Blatz, Markus B; Koizuka, Mai; Taguchi, Kohei; Matsumura, Hideo

    2012-10-01

    This study aims to evaluate the effect of both feldspathic porcelain coating of zirconia frameworks and priming agents on shear bond strength between an indirect composite material and zirconia frameworks. A total of 462 airborne-particle-abraded zirconia disks were divided into three groups: untreated disks (ZR-AB), airborne-particle-abraded zirconia disks coated with feldspathic porcelain, (ZR-PO-AB), and hydrofluoric acid-etched zirconia disks coated with feldspathic porcelain (ZR-PO-HF). Indirect composite (Estenia C&B) was bonded to zirconia specimens with no (CON) or one of four priming agents--Clearfil Photo Bond (CPB), Clearfil Photo Bond with Clearfil Porcelain Bond Activator (CPB + activator), Estenia Opaque primer, or Porcelain Liner M Liquid B (PLB)--with or without an opaque material (Estenia C&B Opaque). All specimens were tested for shear bond strength before and after 20,000 thermocycles. The Steel-Dwass test and Mann-Whitney U test were used to compare shear bond strength. In ZR-AB specimens, the initial bond strength of the CPB and CPB + Activator groups was significantly higher as compared with the other three groups (P < 0.05), whereas the PLB and CPB + Activator groups had the highest pre- and post-thermocycling bond strengths in ZR-PO-AB and ZR-PO-HF specimens. Among CON disks without opaque material, bond strength was significantly lower in ZR-AB specimens than in ZR-PO-AB and ZR-PO-HF specimens (P < 0.05). Feldspathic porcelain coating of a Katana zirconia framework enhanced the bond strength of Estenia C&B indirect composite to zirconia independent of surface treatment. The use of a silane coupling agent and opaque material yields durable bond strength between the indirect composite and feldspathic-porcelain-coated zirconia. The results of the present study suggest that feldspathic porcelain coating of zirconia frameworks is an effective method to obtain clinically acceptable bond strengths of a layering indirect composite material to a zirconia framework.

  18. Porcelain enamel neutron absorbing material

    DOEpatents

    Iverson, D.C.

    1987-11-20

    A porcelain enamel composition as a neutron absorbing material can be prepared of a major proportion by weight of a cadmium compound and a minor proportion of compound of boron, lithium and silicon. These compounds in the form of a porcelain enamel coating or layer on several alloys has been found to be particularly effective in enhancing the nuclear safety of equipment for use in the processing and storage of fissile material. The composition of the porcelain enamel coating can be tailored to match the coefficient of thermal expansion of the equipment to be coated and excellent coating adhesion can be achieved. 2 figs.

  19. PIXE analysis of ancient Chinese Qing dynasty porcelain

    NASA Astrophysics Data System (ADS)

    Cheng, Huansheng; He, Wenquan; Tang, Jiayong; Yang, Fujia; Wang, Jianhua

    1996-09-01

    The major and minor chemical compositions and trace element content of white glaze made in Qing dynasty at kuan kiln have been determined by PIXE. Experimental results show that trace element contents RbSrZr are useful to distinguish the place of production of ancient porcelain. In the porcelain from different kilns situated in a same province, the trace element contents can be different from each other. Determining and comparing the major and minor compositions and trace elemental concentrations in white glaze by PIXE technique, we can distinguish a precious Qing dynasty porcelain made at kuan kiln from a fake.

  20. [Color stability of porcelain-fused-to-titanium restorations after repeated firings].

    PubMed

    Wu, Xiao-min; Zhou, Zheng

    2004-08-01

    To study the effect of repeated firings on color of porcelain-fused-to-titanium restorations. Twenty standard porcelain-fused-to-titanium specimens were made with Dentsply DETREY TiBond C3 and Dentaurum rematitan Til. Then they were fired 1, 2, 4, 7, and 10 times. Color measurement was done after each firing. Most of the color parameters had no significant difference after firing except for a* and Hab. All the color difference among groups were smaller than 1.0 (deltaE < 1.0). Repeated firings will not affect the color stability of porcelain-fused-to-titanium restorations.

  1. [Clinical analysis of laser welding on porcelain bonded metal surface].

    PubMed

    Weng, Jia-wei; Dai, Wen-an; Wu, Xue-ying

    2011-02-01

    To evaluate the clinical effect of laser-welded crowns and bridges. Two hundred defective crowns and bridges were welded by using Heraplus laser welding machine, and then restored by porcelain. After being welded ,those defective crowns and bridges of different materials fit well and their marginal areas were also satisfactory. During the follow up period of one year, no fractured porcelain and crack were found at welding spots. The technology of laser welding has no direct effect on welding spots between metal and porcelain and could be used to deal with the usual problems of the crowns and bridges.

  2. Porcelain enamel neutron absorbing material

    DOEpatents

    Iverson, Daniel C.

    1990-01-01

    A porcelain enamel composition as a neutron absorbing material can be prepared of a major proportion by weight of a cadmium compound and a minor proportion of compounds of boron, lithium and silicon. These compounds in the form of a porcelain enamel coating or layer on several alloys has been found to be particularly effective in enhancing the nuclear safety of equipment for use in the processing and storage of fissile material. The composition of the porcelain enamel coating can be tailored to match the coefficient of thermal expansion of the equipment to be coated and excellent coating adhesion can be achieved.

  3. Porcelain enamel neutron absorbing material

    DOEpatents

    Iverson, Daniel C.

    1990-02-06

    A porcelain enamel composition as a neutron absorbing material can be prepared of a major proportion by weight of a cadmium compound and a minor proportion of compounds of boron, lithium and silicon. These compounds in the form of a porcelain enamel coating or layer on several alloys has been found to be particularly effective in enhancing the nuclear safety of equipment for use in the processing and storage of fissile material. The composition of the porcelain enamel coating can be tailored to match the coefficient of thermal expansion of the equipment to be coated and excellent coating adhesion can be achieved.

  4. Study on the chemical composition features of Longquan celadon excavated from the Chuzhou site of Huai'an City in Jiangsu Province by EDXRF

    NASA Astrophysics Data System (ADS)

    Li, Li; Feng, Song-Lin; Feng, Xiang-Qian; Xu, Qing; Yan, Ling-Tong; Ma, Bo; Huo, Hua

    2011-07-01

    A mass of Longquan celadon shards were excavated from the Chuzhou site of Huai'an City in Jiangsu Province, China. These celadon shards were fired during the period of the Late Yuan Dynasty to the Tianshun era of the Ming Dynasty, as identified by archaeologists at Nanjing Museum. In order to research the chemical composition features of this ancient celadon porcelain, energy dispersive X-ray fluorescence (EDXRF) for non-destructive analysis was used to determine the chemical composition of the porcelain body and glaze in these shards. The results indicate that Ti and Fe in the body of Longquan celadon are characteristic elements which can distinguish porcelain produced during the Late Yuan Dynasty from those produced in the Ming Dynasties. The results of the principal component analysis (PCA) show that different body and glaze raw materials were used for the production of porcelain in different periods and the raw materials of the body and glaze are also different for various vessel shapes. The chemical compositions in the porcelain body of civilian ware are slightly different. The imperial and civilian Longquan celadon porcelains produced during the Hongwu era to the Tianshun era of the Ming Dynasty are distinguishable by the MnO, Fe2O3, Rb2O and SrO content in their porcelain glaze.

  5. [Interface bond and compatibility between Mark II machining ceramic and vita VM9 veneering porcelain].

    PubMed

    Liu, Tian-Shuang; Li, Zhen-Chun; Chen, Xiao-Dong

    2009-04-01

    To investigate the interface bond and thermal compatibility between Mark II machining ceramic and Vita VM9 veneering porcelain. A bar shaped specimen (30 mm x 15 mm x 1 mm in size) of Mark II block was prepared, with 0.5 mm-deep notch (vertical to the long axis of specimen) at the middle of the bottom surface. The upper surface was veneered with 0.3 mm VM9 dentin base porcelain. Then the specimen was fractured from the notching site and the fracture surface was examined under scanning electron microscope (SEM) and electron microprobe analyzer (EMPA) with electron beam of 1 microm in diameter. Another ten specimens (30 mm x 15 mm x 1.5 mm in size) were fabricated and the temperature of thermal shock resistance were tested. SEM observation showed tight bond between these two materials and EMPA results showed penetration of Al element from Mark II block into veneering porcelain and Ca element from veneering porcelain into Mark II block occurred after sintering baking. The average temperature of thermal shock resistance for specimens in this study was (194.0+/-10.3) degrees C. Cracks were mainly distributed in veneering porcelain. Chemical bond exists between the Mark II machining ceramic and Vita VM9 veneering porcelain, and there is good thermal compatibility between them.

  6. Characteristics and porcelain bond strength of (Ti,Al)N coating on dental alloys.

    PubMed

    Chung, Kwok-Hung; Duh, Jeng-Gong; Shin, Daehwan; Cagna, David R; Cronin, Robert J

    2002-01-01

    The effect of a novel titanium-aluminum nitride film, or (Ti,Al)N film, on the bond strength between a dental porcelain and two nickel-based dental alloy substrates was investigated. A thin layer of (Ti,Al)N film was deposited on flat metal samples using a reactive radio-frequency sputtering method. A uniform thickness of porcelain was applied to the film- coated metal samples. Metal-ceramic specimens were subjected to three-point bending, and failure loads were recorded. Bond strengths between the porcelain and (Ti,Al)N-coated metal alloys ranged from 159.0 +/- 11.7 N to 278.0 +/- 12.3 N. These values were significantly greater (p< 0.05) than bond strengths recorded for control samples that did not incorporate the (Ti,Al)N film. An electron probe microanalyzer with a line profile mode was used to characterize the interface between the (Ti,Al)N film and the porcelain. Results of this investigation suggest that the (Ti,Al)N film (1) increases the flexural bond strength between dental porcelain and nickel-based alloy substrates by permitting elemental diffusion, (2) interferes with the surface oxide formation that characteristically originates from the nickel-based metal alloy substrate, and (3) provides an appropriate oxide layer for porcelain application. Copyright 2002 Wiley Periodicals, Inc. J Biomed Mater Res (Appl Biomater) 63: 516-521, 2002

  7. 75 FR 81967 - Porcelain-on-Steel Cooking Ware From Taiwan: Final Results of Sunset Review and Revocation of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-29

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-583-508] Porcelain-on-Steel Cooking... duty order on porcelain-on-steel cooking ware (POS cooking ware) from Taiwan pursuant to section 751(c... the antidumping duty order on POS cooking ware from Taiwan. DATES: Effective Date: November 22, 2010...

  8. [Effect of staining method and sintering temperature on the color of porcelain-fused-to-metal restorations].

    PubMed

    Wang, Yan; Yan, Wei-hao; Zhang, Xin-chun; Huang, Yue; Shen, Lin-han

    2004-12-01

    To investigate the effect of staining method and sintering temperature on the color of porcelain-fused-metal restorations. 40 cylindrical stained porcelain-metal specimens of 15 mm in diameter and 6 mm in height were fabricated with customized mould, consisting of 2 mm Ni-Cr metal, 1 mm opaque porcelain, 2 mm dentine porcelain and 1 mm enamel porcelain. The specimens were prepared by 5 techniques, 8 for each group. Group A: internal staining, Group B: external staining, 900 degrees centigrade sintering temperature was used in both A and B group; Group C to E: external staining, with the sintering temperature of 880 degrees centigrade, 900 degrees centigrade and 920 degrees centigrade respectively. Sofu A2 porcelain and Sofu 44 stain system were used for the study. Using standard white plate as a reference, colors (L*,a*,b* coordinates) of the specimens were measured with a computerized colorimeter. Student's t test and one way ANOVA were used to analyze the data. DeltaE, b* and Delta C(ab)* of Group B (external staining) and group A (internal staining) were 43.72 +/- 2.99/26.51 +/- 1.64/31.31 +/- 2.48 and 39.71 +/- 1.78/23.69 +/- 0.36/26.55 +/- 2.16, respectively. The values of the former group were significantly higher than that of the latter (P < 0.05); For Group C to E, there were no significant differences in all the color parameters. Staining method has a significant effect on the color parameters of porcelain-fused-to-metal restorations; For external staining, within the clinically-used range, changing the sintering temperature does not have an obvious effect on the color.

  9. Evaluation to the effect of B2O3-La2O3-SrO-Na2O-Al2O3 bonding agent on Ti6Al4V-porcelain bonding.

    PubMed

    Zhao, C Q; Wu, S Q; Lu, Y J; Gan, Y L; Guo, S; Lin, J J; Huang, T T; Lin, J X

    2016-10-01

    Low-fusing bonding agents have been widely applied in Ti-ceramics restorations. As an important category, borate bonding agents have great potentials in increasing Ti-porcelain bonding. The purpose of this study is to evaluate the effect of borate bonding agent with addition of Na2O and Al2O3 on Ti6Al4V-porcelain bonding. The thermal properties of borate bonding agent, such as glass transition temperature (Tg) and crystallization peak temperature (Tp), were investigated to establish the sintering process. And the coefficient of thermal expansion (CTE) was to evaluate the matching effect of porcelain to Ti6Al4V. The bond strength was analyzed by the three point bending test. The microscopic morphology of the borate bonding agent surface after sintering, the interface of Ti-borate bonding agent-porcelain, and the fracture mode after porcelains fracture, were studied to assess the influence of borate bonding agent on Ti6Al4V-ceramics. With the addition of Na2O and Al2O3, the porcelain residues were observed increased indication on the Ti6Al4V surface after porcelain fracture and the bond strength was acquired the maximum (49.45MPa) in the bonding agent composition of 75.70B2O3-5.92La2O3-11.84SrO-4.67Na2O-1.87Al2O3. Those results suggest that borate bonding agent is an effective way to improve the Ti6Al4V-ceramics bond strength. And the addition of Na2O and Al2O3 strengthen this effect. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Evaluation of the effect of a home-bleaching agent on the surface characteristics of indirect esthetic restorative materials: part I--roughness.

    PubMed

    Torabi, Kianoosh; Rasaeipour, Sasan; Khaledi, Amir Alireza; Vojdani, Mahroo; Ghodsi, Safoura

    2014-05-01

    Pressing esthetic demands of good looking make people undergo bleaching procedures. However, the effect of bleaching agents on esthetic restorative materials with different surface preparations has been poorly studied. The aim of this study was to examine the effect of a homebleaching agent (carbamide peroxide: CP 38%) on the surface roughness of the polished fiber reinforced composite (FRC), overglazed, autoglazed, or polished ceramic samples. Twenty standardized cylindrical specimens were made of each of the following groups: over-glazed, autoglazed, polished porcelain and also FRC. The test specimens exposed to the CP 38%, 15 minutes, twice a day for 2 weeks according to the manufacturer's recommendation. Six samples from each group were selected randomly to form negative controls. Surface roughness measurements (Ra, micrometer) for baseline, test and control specimens were performed by use of a profilometer. Paired t-test, Mann-Whitney test, and Kruskal-Wallis test were used for statistical analyses. The data showed that bleaching with CP 38% significantly increased the surface roughness of all the test samples (p < 0.05). The type of surface preparation caused significant differences between the susceptibility of porcelain subgroups to bleaching (p < 0.05). The polished porcelain specimens showed the highest changes after bleaching. CP 38% significantly increases the surface roughness of the porcelains and FRC. The type of surface condition affects the amenability of the porcelain surface to the bleaching agent. Glazed porcelains were more resistant to roughness than the polished porcelains and also the composite. Roughening of porcelain and FRC occur following bleaching procedure. No special surface preparation of indirect esthetic restorative materials can completely preserve these materials from adverse effects of bleaching agents.

  11. Evaluation of the Effect of Porcelain Laminate Thickness on Degree of Conversion of Light Cure and Dual Cure Resin Cements Using FTIR

    PubMed Central

    Hoorizad Ganjkar, Maryam; Heshmat, Haleh; Hassan Ahangari, Reza

    2017-01-01

    Statement of the Problem: Increasing the thickness of the veneering porcelain may affect the polymerization of resin cements. Incomplete polymerization of resin cements can lead to compromised quality of restoration and decrease the longevity of indirect restorations. Purpose: This study sought to assess the effect of IPS Empress porcelain thickness on the degree of conversion of light-cure and dual-cure resin cements using Fourier transform infrared spectroscopy. Materials and Method: In this experimental study, IPS Empress porcelain discs (A2 shade) with 10mm diameter and 0.5, 1 and 1.5 mm thicknesses were fabricated. Choice2 (Bisco, USA) and Nexus3 (Kerr, USA) resin cements were light cured through the three porcelain thicknesses in two groups of 3 samples using a LED light-curing unit (LEDemetron II; Kerr, USA). The control group samples were cured individually with no porcelain disc. The degree of conversion of resin cements was determined using FTIR (Bruker; Equinox55, Germany). The data were analyzed using Dunn’s test. Results: The degree of conversion (in percent) beneath the 0.5, 1.5 and 2 mm thicknesses of IPS Empress was 68.67±0.88, 71.06±0.94 and 72.51±0.41 for Choice2 resin cement and 69.60±2.12, 69.64±1.63 and 69.24±2.12 for Nexus3, respectively. Porcelain thickness and type of resin cement had no significant effect on degree of conversion (p≥ 0.05). Conclusion: It seems that increasing the porcelain thickness by up to 1.5 mm has no adverse effect on degree of conversion of both dual cure and light cure resin cements evaluated in this study. PMID:28280757

  12. [Effect of preparation methods on the metal-porcelain bond strength of Co-Cr alloys].

    PubMed

    Liu, Jie; Chi, Shuai; Xu, Jin; Wang, Yanyan; Zhan, Desong

    2014-04-01

    To compare the shear bond strength(SBS) of cast Co-Cr alloys and selective laser melting(SLM) Co-Cr alloys with those of dental porcelain. A dental porcelain (Vita) was applied on cast and SLM Co-Cr alloy specimens (n = 10). SBS test was conducted, and fracture mode analysis was determined. Student's t-test by SPSS 13.0 software was employed to analyze the data. The SLM Co-Cr alloy specimens had lower SBS values than the cast Co-Cr alloy specimens (P > 0.05). The metal-porcelain bond strength value of the cast group was (33.11 +/- 4.98) MPa, and that of the SLM group was (30.94 +/- 5.98) MPa. The specimens in both test groups exhibited mixed failure. The metal-porcelain system processed by SLM exhibit a bond strength that is similar to that of the cast group. This system also display a high precision.

  13. Effect of sandblasting on surface roughness of zirconia-based ceramics and shear bond strength of veneering porcelain.

    PubMed

    He, Min; Zhang, Zutai; Zheng, Dongxiang; Ding, Ning; Liu, Yan

    2014-01-01

    This study aims to investigate the effect of sandblasting on the surface roughness of zirconia and the shear bond strength of the veneering porcelain. Pre-sintered zirconia plates were prepared and divided into four groups. Group A were not treated at all; group B were first sandblasted under 0.2 MPa pressure and then densely sintered; group C and D were sintered first, and then sandblasted under 0.2 MPa and 0.4 MPa pressures respectively. Surface roughness was measured and 3D roughness was reconstructed for the specimens, which were also analyzed with X-ray diffractometry. Finally after veneering porcelain sintering, shear bond tests were conducted. Sandblasting zirconia before sintering significantly increased surface roughness and the shear bond strength between zirconia and veneering porcelain (p<0.05). Sandblasting zirconia before sintering is a useful method to increase surface roughness and could successfully improve the bonding strength of veneering porcelain.

  14. Cross-contamination in Porcelain Mortars.

    PubMed

    Bauer-Brandl, A; Falck, A; Ingebrigtsen, L; Nilson, C

    2001-01-01

    Porcelain mortars and pestles are frequently used to comminute drug substances on a small scale and (in some cases) in the production of liquid and semisolid suspensions. Although it is generally accepted that removal of a drug substance from a rough surface by rinsing may be difficult and may lead to cross-contamination, no hard data support that theory. In this study, the amount of salicylic acid remaining on a porcelain mortar after different washing procedures was quantified and compared with the amount remaining on a plastic mortar. Drug residues in the "mg" range on the porcelain mortars made common rinsing procedures appear inappropriate, but no traces of drug were detected on plastic mortars. In addition, the quality of suspension ointments with respect to particle size and homogeneity produced by the two types of mortars was compared. Porcelain and plastic mortars appeared equally suitable for use in the production of semisolid suspensions.

  15. [Study on the matching of the shade between beverage and modifying porcelain shade guide].

    PubMed

    Yao, Jiang-wu; Li, Shui-gen; Lin, Jin-ying

    2007-10-01

    To evaluate the matching of the shade between beverage and modifying porcelain shade guide according to Munsell color order system, thus to provide the reference basis for selecting modifying porcelain to mimic the stain of natural tooth by technician. The shade of Vita Akzent, Vita Interno, Shofu Vintage & Unibond and Noritake Super Porcelain EX-3 shade tabs as well as 15 kinds of beverage were measured according to Munsell color order system on Color-Eye 7000A spectrophotometer. The difference of the frequency of approximate hue, value, and chroma between shade tabs and beverage were compared by calculating the Fisher exact probabilities. The frequency of approximate hue between 4 kinds of shade tabs and 15 kinds of bev-erage was significant different (P<0.05), while the frequency of approximate value, and chroma was not significant different (P>0.05). Except the hue, the color distribution of 4 kinds of shade tabs was similar to that of 15 kinds of beverage. But the color of beverage also can be approximately matched by any kind of modifying porcelain by mixing porcelain powder of appropriate hue, value, and chroma.

  16. [Determination of the dynamic levels of interleukin-8 in gingival crevicular fluid of porcelain teeth with three different alloys].

    PubMed

    Xu, Weixing; Su, Jiansheng

    2012-06-01

    To study the interleukin-8 (IL-8) levels in gingival crevicular fluid (GCF) of porcelain teeth coated with Ni-Cr, Co-Cr or gold alloy at different time periods, and to uncover the degree of stimulation by these alloys on gingiva at different time periods. 45 cases of porcelain teeth coated with Ni-Cr, Co-Cr or gold alloy were selected randomly, with 15 cases in each group. Sandwich enzyme-linked immunosorbent assay (ELISA) was used to determine the concentration and total amount of IL-8 in GCF. The assay was done before treatment, as well as at 1, 3 and 6 months post-treatment. The total amounts of IL-8 and GCF volume in the Ni-Cr alloy coated porcelain teeth were higher in different time period than those before treatment (P<0.05). However, the IL-8 levels in Co-Cr and gold alloy coated porcelain teeth returned to pre-dental restoration after 3 months. Otherwise, the levels of IL-8 concentration in GCF showed no significant difference among the three different alloys coating at different time periods. IL-8 is an important cytokine during tissue inflammation. Therefore, the level of IL-8 in GCF is a useful criteria for the evaluation of stimulation degree on gingiva by different alloy coating materials in porcelain teeth. The clinical choice of different alloy coating for porcelain teeth should be considered accordingly.

  17. Effects of different electrolytes for micro-arc oxidation on the bond strength between titanium and porcelain.

    PubMed

    Yuan, Xiaohui; Tan, Fei; Xu, Haitao; Zhang, Shaojun; Qu, Fuzhen; Liu, Jie

    2017-07-01

    The aim of this study is to investigate the effects of different electrolytes on the titanium-porcelain bond strength after micro-arc oxidation (MAO) treatment. Three electrolytes at the same concentration were used as MAO reaction solutions: Na 2 SiO 3 , KF, and MgSiF 6 . Blasting treatment was chosen as a control. After MAO treatment in each electrolyte, the titanium-porcelain bond strengths were measured by the three-point bending test, as described in ISO 9693. The morphologies and elemental compositions of the MAO coating on the titanium substrate were evaluated by scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS). The interface between the titanium and porcelain was also observed by SEM and EDS. The MAO coatings created in different electrolytes exhibited completely different morphologies and compositions. The bond strengths of the Na 2 SiO 3 and MgSiF 6 groups were significantly higher than those of the other groups (p<0.05). Additionally, the titanium-porcelain interfaces were compact in the former two groups, whereas pores and cracks were visible at the interfaces in the other groups. These results indicate that MAO treatment with an appropriate electrolyte could be an effective method to increase the titanium-porcelain bonding strength. According to ISO 9693, titanium-porcelain restorations subjected to MAO treatment with an appropriate electrolyte could be appropriate for clinical use. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  18. Luminescent Method for Porcelain Identification

    NASA Astrophysics Data System (ADS)

    Platova, R. A.; Rassulov, V. A.; Platov, Yu. T.

    2018-05-01

    Porcelain identification according to the material type (hard, soft, and bone) was reduced to a system of classification functions that were constructed based on interrelationships of luminescence band intensities of optically active impurity centers (Fe3+ and Mn2+), a molecular center ({UO}_2^{2+}) , and intrinsic defects (O*, oxygen center). Porcelains with different compositions and calcination conditions had different combinations and intensity ratios of bands of optically active centers.

  19. Apico-brachiocephalic artery bypass for aortic stenosis with porcelain aorta.

    PubMed

    Shimizu, Shuji; Nakai, Mikizo; Itoh, Atsushi; Yoshizumi, Ko; Ochi, Yoshiki; Okada, Masahiro; Sano, Shunji

    2010-02-01

    Apicoaortic bypass for left ventricular outflow tract obstruction has been performed with acceptable mid-term mortality. However, sometimes it is difficult to anastomose the distal end of the conduit to the calcified descending aorta in patients with a porcelain aorta. We report an aortic non-touch modification of the apicoaortic bypass in an 80-year-old woman with valvular aortic stenosis and a porcelain aorta extending from the ascending to abdominal aorta. We performed apico-brachiocephalic artery bypass under circulatory arrest with deep hypothermia. This procedure may become a useful surgical option for patients with a severe porcelain aorta. 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Evaluation of Porcelain Cup Soil Water Samplers for Bacteriological Sampling1

    PubMed Central

    Dazzo, Frank B.; Rothwell, Donald F.

    1974-01-01

    The validity of obtaining soil water for fecal coliform analyses by porcelain cup soil water samplers was examined. Numbers from samples of manure slurry drawn through porcelain cups were reduced 100- to 10,000,000-fold compared to numbers obtained from the external manure slurry, and 65% of the cups yielded coliform-free samples. Fecal coliforms adsorbed to cups apparently were released, thus influencing the counts of subsequent samples. Fecal coliforms persisted in soil water samplers buried in soil and thus could significantly influence the coliform counts of water samples obtained a month later. These studies indicate that porcelain cup soil water samplers do not yield valid water samples for fecal coliform analyses. Images PMID:16349998

  1. The Earliest Chinese Proto-Porcelain Excavated from Kiln Sites: An Elemental Analysis

    PubMed Central

    Li, Yu; Zhang, Bin; Cheng, Huansheng; Zheng, Jianming

    2015-01-01

    In June 2012, the Piaoshan kiln site was excavated in Huzhou, Zhejiang Province, which hitherto proved to be the earliest known Chinese proto-porcelain kiln. Judging from the decorative patterns of unearthed impressed stoneware and proto-porcelain sherds, the site was determined to date to the late Xia (c. 2070–c. 1600 BC), the first dynasty of China. Here, we report on proton-induced X-ray emission analyses of 118 proto-porcelain and 35 impressed stoneware sherds from Piaoshan and five subsequent kiln sites in the vicinity. Using principal components analysis on the major chemical compositions, we reveal the relationships between impressed stoneware and proto-porcelain samples from the six kiln sites. The sherds from different sites have distinctive chemical profiles. The results indicate that the raw materials were procured locally. We find a developmental tendency for early glazes towards mature calcium-based glaze. It is most likely that woody plant ashes with increased calcia-potash ratios were applied to the formula. PMID:26535583

  2. [Effect of porcelain firing cycle on microstructure and corrosion resistance of 4 metal ceramic alloys].

    PubMed

    Chen, Lei; Cai, Hui; Xu, Guo-fu; Fang, Chang-yun

    2006-06-01

    To determine the effect of porcelain firing cycle on microstructure of 4 metal ceramic alloys, and to analyze the changes of their corrosion resistance in the artificial saliva. We simulated the process of firing and repolishing when fabricating porcelain-fused-to-metal restoration in clinic,and then observed the microstructures of Ni-Cr, Ni-Cr-Ti, Co-Cr alloys and high gold alloy by field emission scanning electron microscopy and energy dispersive spectroscopy. The electrochemical corrosion behavior of alloys in artificial saliva was analyzed by polarization curves and corrview 2 corrosion analysis software. The data of self-corrosion potential and transpassive potential were obtained and analyzed. After the porcelain firing cycle, the surface composition changed slightly, and the morphological in the 3 predominate base metal alloys also changed. The self-corrosion potential turned to more negative, and the transpassive potential declined. The procedure of porcelain firing cycle can affect the surface microstructure and increase the corrosion of 4 metal-ceramic alloys.

  3. Study on the elemental features of ancient Chinese white porcelain at Jingdezhen by INAA

    NASA Astrophysics Data System (ADS)

    Xie, Guoxi; Feng, Songlin; Feng, Xiangqian; Li, Yongqiang; Han, Hongye; Wang, Yanqing; Zhu, Jihao; Yan, Lingtong; Li, Li

    2009-03-01

    Shards of ancient Chinese white porcelain, which were excavated at Maojiawan in the city of Beijing, were analyzed by instrumental neutron activation analysis (INAA). These shards were fired in the period between the Yuan (AD 1271-1368) and Ming (AD 1368-1644) dynasties at Jingdezhen in southern China. According to the analytical results, different raw materials were used for making porcelain body in this period. Fe and Na are the characteristic elements which can be used for identifying the specific date of these porcelains. Furthermore, shards of Hongwu era (AD 1368-1398), Yongle-Xuande era (AD 1403-1435) and Chenghua-Zhengde era (AD 1465-1561) of the Ming dynasty can be clearly distinguished by their elemental body composition. The temporal chemical variation in the porcelain body of these eras is observed. The elemental body composition of Zhengde-Tianshun era (AD 1436-1464) is mainly similar to that of the Hongwu and Yongle-Xuande eras. The temporal chemical feature of Zhengtong-Tianshun era was not found.

  4. The Earliest Chinese Proto-Porcelain Excavated from Kiln Sites: An Elemental Analysis.

    PubMed

    Li, Yu; Zhang, Bin; Cheng, Huansheng; Zheng, Jianming

    2015-01-01

    In June 2012, the Piaoshan kiln site was excavated in Huzhou, Zhejiang Province, which hitherto proved to be the earliest known Chinese proto-porcelain kiln. Judging from the decorative patterns of unearthed impressed stoneware and proto-porcelain sherds, the site was determined to date to the late Xia (c. 2070-c. 1600 BC), the first dynasty of China. Here, we report on proton-induced X-ray emission analyses of 118 proto-porcelain and 35 impressed stoneware sherds from Piaoshan and five subsequent kiln sites in the vicinity. Using principal components analysis on the major chemical compositions, we reveal the relationships between impressed stoneware and proto-porcelain samples from the six kiln sites. The sherds from different sites have distinctive chemical profiles. The results indicate that the raw materials were procured locally. We find a developmental tendency for early glazes towards mature calcium-based glaze. It is most likely that woody plant ashes with increased calcia-potash ratios were applied to the formula.

  5. Surface topography and bond strengths of feldspathic porcelain prepared using various sandblasting pressures.

    PubMed

    Moravej-Salehi, Elham; Moravej-Salehi, Elahe; Valian, Azam

    2016-11-01

    The purpose of this study was to determine the bond strength of composite resin to feldspathic porcelain and its surface topography after sandblasting at different pressures. In this in vitro study, 68 porcelain disks were fabricated and randomly divided into four groups of 17. The porcelain surface in group 1 was etched with hydrofluoric acid. Groups 2, 3, and 4 were sandblasted at 2, 3 and 4 bars pressure, respectively. Surface topography of seven samples in each of the four groups was examined by a scanning electron microscope (SEM). The remaining 40 samples received the same silane agent, bonding agent, and composite resin and they were then subjected to 5000 thermal cycles and evaluated for shear bond strength. Data were analyzed using one-way anova. The mode of failure was determined using stereomicroscope and SEM. The highest shear bond strength was seen in group 4. however, statistically significant differences were not seen between the groups (P = 0.780). The most common mode of failure was cohesive in porcelain. The SEM showed different patterns of hydrofluoric acid etching and sandblasting. Increasing the sandblasting pressure increased the surface roughness of feldspathic porcelain but no difference in bond strength occurred. © 2015 Wiley Publishing Asia Pty Ltd.

  6. [Evaluation of bond strength between low fusing porcelain with goldplated cobalt-chromium alloys].

    PubMed

    Guo, Jing; Zhu, Jia; Zhu, Hong-shui

    2014-02-01

    To evaluate the bond strength of Vita OMEGA 900 low fusing porcelain fused with the goldplated Wirobond cobalt-chrome metalt ceramic alloy. Low fusing porcelain was fused with the cobalt-chromium alloy strips(group A) and the goldplated cobalt-chromium alloy strips(group B) respectively according to ISO9693 (A:8,B:10). 8 specimens of each group were submitted to three point bending test. Two more test pieces fused with gold plated cobalt-chromium alloys were made (group B'). One test piece of both group B and group B' were observed under scanning electron microscope (SEM) randomly. The data was analyzed with SPSS 16.0 software package. The bond strength (MPa) of group A and group B was 29.92±4.28 and 28.20±5.21, respectively (P>0.05), both higher than 25 MPa required by ISO9693. SEM showed that Vita OMEGA 900 low fusing porcelain and the goldplated Wirobond cobalt-chrome metalt ceramic alloy combined together closely without cracks. Much gold was fused to the cobalt-chrome alloy surface of breaking porcelain specimen after testing. Vita OMEGA 900 low fusing porcelain can match with the goldplated Wirobond cobalt-chrome metalt ceramic alloy. Supported by Foundation of Education Department of Jiangxi Province (GJJ10367).

  7. [Research of the surface oxide film on anodizing Ni-Cr porcelain alloy].

    PubMed

    Zhu, Song; Sun, Hong-Chen; Zhang, Jing-Wei; Li, Zong-Hui

    2006-08-01

    To study the shape, thickness and oxide percentage of major metal element of oxide film on Ni-Cr porcelain alloy after anodizing pretreatment. 10 samples were made and divided into 2 groups at random. Then after surface pretreatment, the oxide films of two samples of each group were analyzed using electronic scanning microscope. The rest 3 samples were measured by X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES). Lightly selective solution appeared because the different component parts of the alloy have dissimilar electrode, whose dissolve velocity were quite unlike. The sample's metal surface expanded, so the mechanical interlocking of porcelain and metal increased bond strength. The thickness of oxide film was 1.72 times of the control samples. The oxide percentage of major metal elements such as Cr, Ni and Mo were higher, especially Cr. It initially involved the formation of a thin oxide bound to the alloy and second, the ability of the formed oxide to saturate the porcelain, completing the chemical bond of porcelain to metal. The method of anodizing Ni-Cr porcelain alloy can easily control the forming of oxide film which was thin and its surface pattern was uniform. It is repeated and a good method of surface pretreatment before firing cycle.

  8. A comparative study on the bond strength of porcelain to the millingable Pd-Ag alloy

    PubMed Central

    Hong, Jun-Tae

    2014-01-01

    PURPOSE The porcelain fused to gold has been widely used as a restoration both with the natural esthetics of the porcelain and durability and marginal fit of metal casting. However, recently, due to the continuous rise in the price of gold, an interest towards materials to replace gold alloy is getting higher. This study compared the bond strength of porcelain to millingable palladium-silver (Pd-Ag) alloy, with that of 3 conventionally used metal-ceramic alloys. MATERIALS AND METHODS Four types of metal-ceramic alloys, castable nonprecious nickel-chrome alloy, castable precious metal alloys containing 83% and 32% of gold, and millingable Pd-Ag alloy were used to make metal specimens (n=40). And porcelain was applied on the center area of metal specimen. Three-point bending test was performed with universal testing machine. The bond strength data were analyzed with a one-way ANOVA and post hoc Scheffe's tests (α=.05). RESULTS The 3-point bending test showed the strongest (40.42 ± 5.72 MPa) metal-ceramic bond in the nonprecious Ni-Cr alloy, followed by millingable Pd-Ag alloy (37.71 ± 2.46 MPa), precious metal alloy containing 83% of gold (35.89 ± 1.93 MPa), and precious metal alloy containing 32% of gold (34.59 ± 2.63 MPa). Nonprecious Ni-Cr alloy and precious metal alloy containing 32% of gold showed significant difference (P<.05). CONCLUSION The type of metal-ceramic alloys affects the bond strength of porcelain. Every metal-ceramic alloy used in this study showed clinically applicable bond strength with porcelain (25 MPa). PMID:25352959

  9. Effect of Thickness and Brand of Metal Ceramic Porcelain on Color

    DTIC Science & Technology

    1991-05-01

    Wasson, Captain 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER AFIT Student Attending: University of...device. Three Vita Lumin shades (A3.5, B1, and C3) of three commercially available dental porcelains that reportedly use shade- matched opaques...Microbond, Ceramco II, and Jelenko) and one commercially available dental porcelain that does not use shade- matched opaques (Vita VMK 68) were used to

  10. Effect of Porcelain Surface Pretreatments on Composite Resin-Porcelain Shear Bond Strength

    DTIC Science & Technology

    1991-05-01

    Presented to the Faculty of The University of Texas Graduate School of Biomedical Sciences at San Antonio in Partial Fulfillment of the Requirements...Breckner III The University of Texas Graduate School of Biomedical Sciences at San Antonio Supervising Professor: Barry K. Norling, Ph.D. The bond between...necessary to pretreat the porcelain prior to luting. The samples were not, however, hydrated or thermally stressed . Sheth et al. (1988) supported the

  11. Technical Achievements in Communist China’s Electrical Equipment Industry

    DTIC Science & Technology

    1960-09-15

    products has also been , developed, including long rod type insulating porcelains and a new series of line porcelains . In 1958, oil sockets for 330...is now aimed at the creation of high intensity, high insulating , and small-size high-tension porcelain products. During the past 10 years, our...of lead-covered oil-immersed paper- insulated cables of 55 kilovolts and less, rubber-sheathed cables of 6,000 volts and less, and aluminum core

  12. [Efficacy of E-max porcelain laminate veneer on esthetic restoration for anterior teeth over 2 years].

    PubMed

    Zhang, Ning; Tao, Lin-shuai; Zhang, Xiao-dong

    2013-12-01

    To evaluate the clinical effect of E-max porcelain laminate veneer on esthetic restoration for anterior teeth over 2 years. E-max porcelain laminate veneer was used in 45 patients with 120 defective anterior teeth. Improved Ryge veneer reexamination standards including the integrity of ceramic veneer, marginal adaptation, gingival health and color match were adopted to evaluate the of clinical effect during 2 years of follow-up. The average satisfaction rate instantly after treatment, 1 year after treatment and 2 years after treatment was 93%, 95% and 94%, respectively. E-max porcelain laminate veneer has fewer side effects, better aesthetics and biological characteristics. The treatment is cost-efficient, safe and long-lasting.

  13. Analysis of elemental maps from glaze to body of ancient Chinese Jun and Ru porcelain by micro-X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Cheng, Lin; Li, Rongwu; Pan, Qiuli; Li, Guoxia; Zhao, Weijuan; Liu, Zhiguo

    2009-01-01

    The reasons how the middle layer of Ru and Jun porcelain between the glaze and body came into being are still not completely understood. Here, elemental maps from the glaze to the body of pieces of ancient Chinese Ru and Jun porcelain were analyzed by micro-X-ray fluorescence. The results show the middle layer was probably formed by the chemical composition of the glaze turning into glassy states and undergoing complex physical-chemical reactions with the body. However, the middle layer of Jun porcelain was formed by the chemical composition of the glaze turning into glassy states and then infiltrating the body at high temperatures during the firing process.

  14. [Effect of TiO2-SiO2-SnOx film with different firing temperatures on bond strength of low-fusing dental porcelain to pure titanium].

    PubMed

    Zhang, Zichuan; Zhang, Pei

    2015-07-01

    To evaluate the influence of TiO(2)-SiO(2)-SnOx nano-coatings with different firing temperatures on the bond strength of low-fusing dental porcelain to pure titanium. The surface of pure titanium was coated uniformly with TiO(2)-SiO(2)-SnOx nano-coatings by solution-gelatin (Sol-Gel) technology and then fired at 300 °C (group A) or 750 °C (group B) for 1 h. The specimens without any coatings were the control group (group C). There were 10 specimens in each group. Dental porcelain was sintered on the surface of titanium specimens. Surface roughness and contact angle of the coatings were also detected. The titanium-porcelain bond strength was investigated according to YY 0621-2008 standards using three-point flexure bond test. The phase composition of the TiO(2)-SiO(2)-SnOx nano-coatings was characterized by X-ray diffraction(XRD). The interface of titanium-porcelain and TiO(2)-SiO(2)-SnOx nano-coatings were observed using scanning electron microscope (SEM). No rutile phase was found in these specimens of group A and group B. The surface roughness of group A, B, C was (0.97 ± 0.06), (0.99 ± 0.03), (0.96 ± 0.07) µm, respectively. No significant difference was found among the three groups. Compared with that of group C (64.37° ± 3.01°), contact angles detected in group A (52.04° ± 3.15°) and group B (85.27° ± 4.17°) were significantly different (P < 0.05). The bond strength of titanium-porcelain in group A [(35.66 ± 2.65) MPa] was significantly increased compared with those in group B [(26.18 ± 2.22) MPa] and group C [(31.66 ± 3.52) MPa]. SEM photomicrographs of titanium-porcelain interface morphology of the specimens before porcelain sintering showed that TiO(2)-SiO(2)-SnOx nano-coatings in group A were compact and homogeneous with petty cracks and those in group B was loose and arranged disorderly. TiO(2)-SiO(2)-SnOx nano-coating fired at 300 °C is significantly effective in improving the titanium-porcelain bond strength.

  15. [Effects of different concentrations of MgSiF(6) as electrolyte for micro-arc oxidation on the bond strength between titanium and porcelain].

    PubMed

    Yuan, M J; Zhang, S J; Liu, J; Tan, F

    2018-02-09

    Objective: To investigate the effects of different concentrations of MgSiF(6) as electrolyte on the bond strength between titanium and porcelain after micro-arc oxidation (MAO) treatment and screen the suitable concentration of MgSiF(6) that can improve the bond strength between titanium and porcelain. Methods: Four different concentrations of MgSiF(6) (10, 20, 30, 40 g/L) were chosen as MAO reaction solutions. Sandblasting treatment was selected as a control group. After porcelain was fused to each specimen, titanium-porcelain bond strengths were evaluated by the three-point bending test according to ISO 9693. Scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS) were adopted to evaluate the morphologies and elemental compositions of both the MAO coatings and the interfaces of the titanium-porcelain restoration. Results: The surface of titanium specimen in the control group was sharp and rough, while specimens in both 10 g/L group and 20 g/L group were porous and homogeneous. However, the pores found on the specimens in the latter group were larger in diameter (approximately 1.0-2.0 μm) than those on the former one (0.2-0.5 μm). The bond strengths of the control group and the experimental groups (10, 20, 30, 40 g/L MgSiF(6)) were (27.08±3.16), (38.18±2.65), (44.75±2.21), (36.44±2.04), (31.04±2.59) MPa, respectively. All the experimental groups showed higher bond strengths than the control group did ( P< 0.05), and the bond strength of 20 g/L MgSiF(6) group was significantly higher than those of the other groups ( P< 0.05). Besides, the interfaces between titanium and porcelain were tight and compact in the 20 g/L group, while different amounts of pores and cracks were visible in the other groups. Additionally, after the three-point bending test, few residual porcelains could be observed on the surfaces of specimens in the control group. Conclusions: MAO treatment with 20 g/L MgSiF(6) on titanium can improve bonding strength between titanium and porcelain.

  16. Effect of autoclave induced low-temperature degradation on the adhesion energy between yttria-stabilized zirconia veneered with porcelain.

    PubMed

    Li, Kai Chun; Waddell, J Neil; Prior, David J; Ting, Stephanie; Girvan, Liz; van Vuuren, Ludwig Jansen; Swain, Michael V

    2013-11-01

    To investigate the effect of autoclave induced low-temperature degradation on the adhesion energy between yttria-stabilized zirconia veneered with porcelain. The strain energy release rate using a four-point bending stable fracture test was evaluated for two different porcelains [leucite containing (VM9) and glass (Zirox) porcelain] veneered to zirconia. Prior to veneering the zirconia had been subjected to 0 (control), 1, 5, 10 and 20 autoclave cycles. The specimens were manufactured to a total bi-layer dimension of 30 mm × 8 mm × 3 mm. Subsequent scanning electron microscopy/energy dispersive spectrometry, electron backscatter diffraction and X-ray diffraction analysis were performed to identify the phase transformation and fracture behavior. The strain energy release rate for debonding of the VM9 specimens were significantly higher (p<0.05) compared to the Zirox specimens across all test groups. Increasing autoclave cycles lowered the strain energy release rate significantly (p<0.05) from 18.67 J/m(2) (control) to the lowest of 12.79 J/m(2) (cycle 10) for only the VM9 specimens. SEM analyses showed predominant cohesive fracture within the porcelain for all cycle groups. XRD analysis of the substrate prior to veneering confirmed a tetragonal to monoclinic phase transformation with increasing the number of autoclave cycles between 5 and 20. The monoclinic phase reverted back to tetragonal phase after undergoing conventional porcelain firing cycles. EBSD data showed significant changes of the grain size distribution between the control and autoclaved specimen (cycle 20). Increasing autoclave cycles only significantly decreased the adhesion of the VM9 layered specimens. In addition, a conventional porcelain firing schedule completely reverted the monoclinic phase back to tetragonal. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  17. On the interfacial fracture of porcelain/zirconia and graded zirconia dental structures.

    PubMed

    Chai, Herzl; Lee, James J-W; Mieleszko, Adam J; Chu, Stephen J; Zhang, Yu

    2014-08-01

    Porcelain fused to zirconia (PFZ) restorations are widely used in prosthetic dentistry. However, their susceptibility to fracture remains a practical problem. The failure of PFZ prostheses often involves crack initiation and growth in the porcelain, which may be followed by fracture along the porcelain/zirconia (P/Z) interface. In this work, we characterized the process of fracture in two PFZ systems, as well as a newly developed graded glass-zirconia structure with emphases placed on resistance to interfacial cracking. Thin porcelain layers were fused onto Y-TZP plates with or without the presence of a glass binder. The specimens were loaded in a four-point-bending fixture with the thin porcelain veneer in tension, simulating the lower portion of the connectors and marginal areas of a fixed dental prosthesis (FDP) during occlusal loading. The evolution of damage was observed by a video camera. The fracture was characterized by unstable growth of cracks perpendicular to the P/Z interface (channel cracks) in the porcelain layer, which was followed by stable cracking along the P/Z interface. The interfacial fracture energy GC was determined by a finite-element analysis taking into account stress-shielding effects due to the presence of adjacent channel cracks. The resulting GC was considerably less than commonly reported values for similar systems. Fracture in the graded Y-TZP samples occurred via a single channel crack at a much greater stress than for PFZ. No delamination between the residual glass layer and graded zirconia occurred in any of the tests. Combined with its enhanced resistance to edge chipping and good esthetic quality, graded Y-TZP emerges as a viable material concept for dental restorations. Copyright © 2014 Acta Materialia Inc. All rights reserved.

  18. [Influence of coping material selection and porcelain firing on marginal and internal fit of computer-aided design/computer- aided manufacturing of zirconia and titanium ceramic implant-supported crowns].

    PubMed

    Cuiling, Liu; Liyuan, Yang; Xu, Gao; Hong, Shang

    2016-06-01

    This study aimed to investigate the influence of coping material and porcelain firing on the marginal and internal fit of computer-aided design/computer-aided manufacturing (CAD/CAM) of zirconia ceramic implant- and titanium ceramic implant-supported crowns. Zirconia ceramic implant (group A, n = 8) and titanium metal ceramic implant-supported crowns (group B, n = 8) were produced from copings using the CAD/CAM system. The marginal and internal gaps of the copings and crowns were measured by using a light-body silicone replica technique combined with micro-computed tomography scanning to obtain a three-dimensional image. Marginal gap (MG), horizontal marginal discrepancy (HMD), and axial wall (AW) were measured. Statistical analyses were performed using SPSS 17.0. Prior to porcelain firing, the measurements for MG, HMD, and AW of copings in group A were significantly larger than those in group B (P < 0.05). After porcelain firing, the measurements for MG of crowns in group A were smaller than those in group B (P < 0.05), whereas HMD and AW showed no significant difference between the two groups (P > 0.05). Porcelain firing significantly reduced MG (P < 0.05) in group A but significantly increased MG, HMD, and AW in group B (P < 0.05) HMD and AW were not influenced by porcelain firing in group A (P > 0.05). The marginal fits of CAD/CAM zirconia ceramic implant-supported crowns were superior to those of CAD/CAM titanium ceramic-supported crowns. The fits of both the CAD/CAM zirconia ceramic implant- and titanium ceramic implant-supported crowns were obviously influenced by porcelain firing.

  19. Color management of porcelain veneers: influence of dentin and resin cement colors.

    PubMed

    Dozic, Alma; Tsagkari, Maria; Khashayar, Ghazal; Aboushelib, Moustafa

    2010-01-01

    Porcelain veneers have become an interesting treatment option to correct the shape and color of anterior teeth. Because of their limited thickness and high translucency, achieving a good color match is influenced by several variables. The aim of this work was to investigate the influence of natural dentin and resin cement colors on final color match of porcelain veneers. A preselected shade tab (A1) was chosen as the target color for a maxillary central incisor, and its color parameters (L*a*b*) were measured using a digital spectrophotometer (SpectroShade, MHT). Nine natural dentin colors (Natural Die Material, Ivoclar Vivadent) representing a wide range of tooth colors were used to prepare resin replicas of the maxillary central incisor with a standard preparation for porcelain veneers. The prepared porcelain veneers (IPS Empress Esthetic, A1, 0.6 mm thick, Ivoclar Vivadent) were cemented on the resin dies (nine groups of natural dentin colors) using seven shades of resin cement (Variolink Veneers, Ivoclar Vivadent). The L*a*b* values of the cemented veneers were measured, and DE values were calculated against the preselected target color (A1). DE greater than 3.3 was considered as a significant color mismatch detectable by the human eye. The seven shades of resin cement had no significant influence on the final color of the veneers, as the measured DE values were almost identical for every test group. On the other hand, the color of natural dentin was a significant factor that influenced final color match. None of the 63 tested combinations (nine natural dentin colors and seven resin cement colors) produced an acceptable color match. Thin porcelain veneers cannot mask underlying tooth color even when different shades of resin cement are used. Incorporation of opaque porcelain (high chroma) may improve final color match.

  20. Evidence of yttrium silicate inclusions in YSZ-porcelain veneers.

    PubMed

    Stoner, Brian R; Griggs, Jason A; Neidigh, John; Piascik, Jeffrey R

    2014-04-01

    This report introduces the discovery of crystalline defects that can form in the porcelain veneering layer when in contact with yttria-stabilized zirconia (YSZ). The focus was on dental prostheses and understanding the defects that form in the YSZ/porcelain system; however the data reported herein may have broader implications toward the use and stability of YSZ-based ceramics in general. Specimens were cut from fully sintered YSZ plates and veneering porcelain was applied (<1 mm thick) to one surface and fired under manufacturer's recommended protocol. Scanning electron microscopy (SEM) with integrated electron dispersive X-ray (EDAX) was used for microstructural and elemental analysis. EDAX, for chemical analysis and transmission electron diffraction (TED) for structural analysis were both performed in the transmission electron microscope (TEM). Additionally, in order to spatially resolve Y-rich precipitates, micro-CT scans were conducted at varying depths within the porcelain veneer. Local EDAX (SEM) was performed in the regions of visible inclusions and showed significant increases in yttrium concentration. TEM specimens also showed apparent inclusions in the porcelain and selected area electron diffraction was performed on these regions and found the inclusions to be crystalline and identified as either yttrium-silicate (Y2 SiO5 ) or yttrium-disilicate (Y2 Si2 O7 ). Micro-CT data showed that yttrium-silicate precipitates were distributed throughout the thickness of the porcelain veneer. Future studies are needed to determine whether many of the premature failures associated with this materials system may be the result of crystalline flaws that form as a result of high temperature yttrium diffusion near the surfaces of YSZ. © 2013 Wiley Periodicals, Inc.

  1. Thermoluminescence and X-ray diffraction studies on sliced ancient porcelain samples

    NASA Astrophysics Data System (ADS)

    Leung, P. L.; Yang, B.

    1999-09-01

    The thermal activation characteristics (TACs) of the sensitivity of the '110°C' peak in 14 sliced ancient Chinese porcelain samples are studied. Comparing with the TACs of natural quartz and synthetic mullite, the relation between the TACs and the composition of the sample is discussed with reference to the X-ray diffraction (XRD) spectra. It is suggested that in some cases, contribution of the porcelain components other than quartz to the TACs is not negligible.

  2. Use of heat-pressed leucite reinforced porcelain in "difficult" veneer cases: a clinical report.

    PubMed

    Rouse, J S

    1996-11-01

    Two clinical situations are presented where a heat-pressed leucite reinforced ceramic veneer system was used. For these situations the system was advantageous when veneers (1) required bulk or variable thicknesses or (2) were under load from function and parafunctional activity. This porcelain veneer system addressed some of the concerns associated with standard feldspathic porcelain and castglass systems. Practitioners should consider its use for situations that require a stronger veneer material.

  3. The Application of a Novel Ceramic Liner Improves Bonding between Zirconia and Veneering Porcelain

    PubMed Central

    Lee, Hee-Sung

    2017-01-01

    The adhesion of porcelain to zirconia is a key factor in the success of bilayered restorations. In this study, the efficacy of a novel experimental liner (EL) containing zirconia for improved bonding between zirconia and veneering porcelain was tested. Four ELs containing various concentrations (0, 3.0, 6.0, and 9.0 wt %) of zirconia were prepared. Testing determined the most effective EL (EL3 containing 3.0 wt % zirconia) in terms of shear bond strength value (n = 15). Three different bar-shaped zirconia/porcelain bilayer specimens were prepared for a three-point flexural strength (TPFS) test (n = 15): no-liner (NL), commercial liner (CL), and EL3. Specimens were tested for TPFS with the porcelain under tension and the maximum load was measured at the first sign of fracture. The strength data were analyzed using one-way ANOVA and Tukey’s test (α = 0.05) as well as Weibull distribution. When compared to NL, the CL application had no effect, while the EL3 application had a significant positive effect (p < 0.001) on the flexural strength. Weibull analysis also revealed the highest shape and scale parameters for group EL3. Within the limitations of this study, the novel ceramic liner containing 3.0 wt % zirconia (EL3) significantly enhanced the zirconia/porcelain interfacial bonding. PMID:28869512

  4. Influence of surface treatments on the shear bond strength of orthodontic brackets to porcelain

    NASA Astrophysics Data System (ADS)

    Wang, Cong; Zeng, Jishan; Wang, Shaoan; Yang, Zheng; Huang, Qian; Chen, Pixiu; Zhou, Shujuan; Liu, Xiaoqing

    2008-11-01

    The purpose of this study was to investigate the effect of various surface treatments after different storage time and thermocycling on the shear bond strength of orthodontic brackets to the feldspathic porcelain surfaces. 128 disc-shaped porcelain specimens were randomly assigned to the following surface treatments: 9.6% HFA, 9.6% HFA combined with silane, 50 μ aluminum trioxide sandblasting followed by silane and application of silane after 37% phosphoric acid. Metal or ceramic brackets were bonded onto each treated porcelain facet with light cured resin. The samples were stored in 37 °C water 1 day or 7 days, thermocycled 500 times from 5 to 55 °C. The shear bond strengths were measured (1 mm/min), and statistically analyzed. The bond failure sites were classified according to ARI system. The surface of the glazed, sandblasted, hydrofluoric and phosphoric acid etched porcelain were examined with SEM. All groups achieved reasonable bond strengths to withstand the application of orthodontic forces. Water storage for 7 days caused lower shear bond strength than that of 1 day. But there is no statistically significant difference between the two groups. The mean shear bond strength provided by ceramic bracket with mechanical retention had no statistical difference with that of metal bracket. Therefore, the optimal treatment for orthodontic brackets bonding to feldspathic porcelain was to apply phosphoric acid combined with silane.

  5. The Effect of Multiple Firings on the Shear Bond Strength of Porcelain to a New Millable Alloy and a Conventional Casting Alloy

    PubMed Central

    Farzin, Mitra; Giti, Rashin; Asalforush-Rezaiye, Amin

    2018-01-01

    This study compared the effect of multiple firings on the shear bond strength (SBS) of porcelain to the new millable alloy (Ceramill Sintron) and a conventional casting alloy (4-all). Thirty-six cylindrical cores (6.8 × 9 mm) were made of millable and castable alloy through CAD/CAM and casting techniques, respectively (n = 18). In the center of each bar, a 4 × 4 × 2-mm shot of porcelain was fused. Having divided each group into 3 subgroups based on the number of firing cycles (3, 5, 7), the specimens were fixed in a universal testing machine and underwent a shear force test (1.5 mm/min crosshead speed) until fractured. Then the SBS values (MPa) were calculated, and the failure patterns were microscopically characterized as adhesive, cohesive, or mixed. Two-way ANOVA statistical test revealed that the number of porcelain firings had no significant effect on the SBS of any of the metal groups (p = 0.1); however, it was statistically higher in the millable group than the castable group (p < 0.05). Moreover, detecting the mixed failure pattern in all the specimens implied that the multiple firings had no significant effect on the failure pattern. The multiple porcelain firings had no significant effect on the SBS of porcelain to neither the millable nor castable alloys. PMID:29565827

  6. Fracture resistance and marginal discrepancy of porcelain laminate veneers influenced by preparation design and restorative material in vitro.

    PubMed

    Lin, Tai-Min; Liu, Perng-Ru; Ramp, Lance C; Essig, Milton E; Givan, Daniel A; Pan, Yu-Hwa

    2012-03-01

    The purpose of this investigation is to evaluate marginal discrepancy and fracture resistance of two veneering materials using two preparation designs. Two veneer preparation designs (full and traditional) were restored with leucite-reinforced ceramic (ProCAD, Ivoclar Vivadent, Amherst, NY) milled by CAD/CAM (Cerec 3D milling system, Serona Dental Systems), and conventional sintered feldspathic porcelain (Noritake Super Porcelain EX3, Noritake Dental Supply Co). Forty-eight specimens were analysed with a sample size of n=12 per group. The thickness of each veneer was measured on four specific surfaces. Marginal discrepancy was evaluated with a replica technique and cross-sectional view using a digital microscope. The fracture resistance of veneers cemented on standardised composite resin dies was evaluated using a universal testing machine. Results were analysed with ANOVA, Tukey-Kramer post hoc testing, and linear regression. The results of this investigation revealed no correlation between the thickness and marginal discrepancy of the veneers. The full preparation design with ProCAD and the traditional preparation design with feldspathic porcelain manifested smaller gap. Fracture resistance was decreased for the full preparation design with feldspathic porcelain. In terms of marginal discrepancy and fracture resistance, the most favourable combination was a traditional veneer preparation design with conventional sintered feldspathic porcelain. For the full veneer preparation, a stronger ceramic material such as ProCAD is suggested. Published by Elsevier Ltd.

  7. Effects of flux concentrations and sintering temperature on dental porcelain

    NASA Astrophysics Data System (ADS)

    Ghose, Polash; Gafur, Md. Abdul; Das, Sujan Kumar; Ranjan Chakraborty, Shyamal; Mohsin, Md.; Deb, Arun Kumar; Rakibul Qadir, Md.

    2014-02-01

    In this study, samples of dental porcelain bodies have been made by using the materials collected from selected deposits employing different mixing proportions of clay, quartz and feldspar. Dental porcelain ceramics have been successfully fabricated by using the sintering technique together with some Na2CO3 additive. The dental porcelain powder has been pressed into pellets at first and subsequently sintered at 700, 800, 900, 1000 and 1100 °C for 2 h. The physical and mechanical properties of the prepared samples have been investigated. The sintering behavior of the fired samples has been evaluated by bulk density, linear shrinkage, water absorption and apparent porosity measurements. This study includes the evaluation of the Vickers's microhardness by microhardness tester. Phase analysis and microstructural study have been performed by XRD and optical microscope respectively. Optical properties have been investigated using UV-visible spectroscopy. Influence of firing conditions on leucite formation, densification and microstructural development of the sintered samples has been investigated. It has been found that the choice of sintering temperature is one of the key factors in controlling leucite crystallization in dental porcelain ceramics. It has also been found that the flux concentration of material and the effect of temperature on preparation of dental porcelain contribute to the firing shrinkage and hardness, which has been found to increase with the increase of treatment temperature.

  8. Principal Component Analysis of Chinese Porcelains from the Five Dynasties to the Qing Dynasty

    NASA Astrophysics Data System (ADS)

    Yap, C. T.; Hua, Younan

    1992-10-01

    This is a study of the possibility of identifying antique Chinese porcelains according to the period or dynasty, using major and minor chemical components (SiO2 , Al2O3 , Fe2O3 , K2O, Na2O, CaO and MgO) from the body of the porcelain. Principal component analysis is applied to published data on 66 pieces of Chinese procelains made in Jingdezhen during the Five Dynasties and the Song, Yuan, Ming and Qing Dynasties. It is shown that porcelains made during the Five Dynasties and the Yuan (or Ming) and Qing Dynasties can be segregated completely without any overlap. However, there is appreciable overlap between the Five Dynasties and the Song Dynasty, some overlap between the Song and Ming Dynasties and also between the Yuan and Ming Dynasties. Interestingly, Qing procelains are well separated from all the others. The percentage of silica in the porcelain body decreases and that of alumina increases with recentness with the exception of the Yuan and Ming Dynasties, where this trend is reversed.

  9. [Infinite optical thickness of dentine porcelain of IPS E.max A color series].

    PubMed

    Sun, Ting; Shao, Long-quan; Yi, Yuan-fu; Deng, Bin; Wen, Ning; Zhang, Wei-wei

    2011-02-01

    To determine the infinite optical thickness of dentine porcelain of IPS E.max A color series. Cylindrical dentine porcelain specimens of the IPS E.max A color series were prepared with a diameter of 13 mm and thickness of 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, and 5.0 mm. The chromatic value of all the specimens was determined with CM-5 spectrometer against standard black and white background. The chromatic aberration (deltaE) was calculated by regression equation. The infinite optical thickness of dentine porcelain of the IPS E.max A color series ranged from 2.341 to 3.333 mm for a deltaE of 1.0, and from 2.064 to 2.904 mm for a deltaE of 1.5. As the chromaticity or thickness increased, the influence by the background color decreased, and the color of specimens became gradually close to the intrinsic color. The thickness of the background dentine porcelain specimens must exceed its infinite optical thickness to represent the intrinsic color and avoid the influence by the extrinsic color.

  10. [Differential study of the bonding characterization of dental porcelain to Ni-Cr alloys].

    PubMed

    Wei, Fang; Zhan, De-song; Wang, Yan-yan

    2008-10-01

    To study the bonding capability when Ni-Cr porcelain alloy was added with Ti, compound rare earth metals and removed the element of Be. Ni-Cr-Ti porcelain alloys manufactured by Institute of Metal Research of Chinese Academy of Sciences were tested. The test alloys were divided into three groups according to whether containing Be and compound rare earth metals or not. And HI BOND Ni-Cr base-metal alloy was chosen as control. The metal-ceramic specimens were prepared for shear test, scanning electron microscope (SEM) and energy spectrum analysis. The shear bond strength of the four groups were analyzed. No significant difference were observed among them (P > 0.05). No crackle was found and they were contacted tightly between the porcelain and metal. The composition and contents of the four groups' interfaces were closed. The shear bond strength of the self-made Ni-Cr-Ti porcelain alloys all can satisfy the clinical requirements. Experimental groups containing Ti, compound rare earth metals and removing the element of Be can be used as better recommendation for clinical practice.

  11. [Long-term observation of 920 porcelain fused to metal prostheses].

    PubMed

    Jiang, Yong-Lin; Sun, Jian; Weng, Wei-Min; Zhang, Fu-Qiang

    2006-10-01

    To evaluate the long-term clinical results of porcelain fused to metal prostheses. Since January 1995, 920 porcelain fused to metal prostheses were fabricated. The long-term outcome were evaluated according to the condition of the prosthese, abutment and the periodontal tissue in the respects of successful rate and causes of failure. 74 patients were found to be during the follow up period, including 36 anterior crowns (46 units), 18 posterior crowns (22 units), 12 percentage of anterior bridges and 8 posterior bridges. The overall failure rate was 8.04%, 4.84% for crown, 8.77% for bridge. The failed prostheses was 5.39%. Porcelain fused to metal prostheses is an ideal method for restoration. The standard process both for the clinician and the technician must be obeyed to improve the success rate.

  12. Chemical Expertise: Chemistry in the Royal Prussian Porcelain Manufactory.

    PubMed

    Klein, Ursula

    2014-01-01

    Eighteenth-century chemists defined chemistry as both a "science and an art." By "chemical art" they meant not merely experimentation but also parts of certain arts and crafts. This raises the question of how to identify the "chemical parts" of the arts and crafts in eighteenth-century Europe. In this essay I tackle this question with respect to porcelain manufacture. My essay begins with a brief discussion of historiographical problems related to this question. It then analyzes practices involved in porcelain manufacture that can be reasonably identified as chemical practices or a chemical art. My analysis yields evidence for the argument that chemical experts and expertise fulfilled distinct technical functions in porcelain manufacture and, by extension, in eighteenth-century "big industry," along with its system of division of labor.

  13. Impulse Flashover Tests at Edgar Beauchamp High Voltage Test Facility, Dixon, California, in Support of Cutler Insulator Failure Investigation

    DTIC Science & Technology

    2006-07-01

    sites. The strength member of the safety core insulators is a fiberglass belt wrapped around pins in the end fittings. Porcelain tubes cover the belt... porcelain tube and heavily tracked the fiberglass belt but left the belt intact structurally (Figure 1). Figure 1. Cutler safety core insulator ...fail-safe insulators . For these tests, the porcelain tube of the safety core insulator was replaced with a plastic see-through tube. The test report [5

  14. Development of Novel Decontamination Techniques for Chemical Agents (GB, VX, HD) Contaminated Facilities. Phase II. Laboratory Evaluation of Novel Agent Decontamination Concepts

    DTIC Science & Technology

    1985-06-21

    mild steel, unpainted mild steel, and porous (i.e., concrete and unglazed porcelain ) test coupons contaminated with agent to a hot-gas composition near...unpainted *’ mild steel, painted stainless steel, concrete, and unglazed porcelain * coupons contaminated with HD, GB, or VX. The detectable limit for the Sub...similar decontamination efficiency was observable in the concrete and unglazed porcelain tests for an initial dose level of 1.8 mg agent/g of material

  15. Surface treatment of dental porcelain: CO2 laser as an alternative to oven glaze.

    PubMed

    Sgura, Ricardo; Reis, Mariana Cavalcante; Hernandes, Antonio Carlos; de Abreu Fantini, Márcia Carvalho; Andreeta, Marcello Rubens Barsi; Medeiros, Igor Studart

    2015-02-01

    This work tested continuous CO2 laser as a surface treatment to dental porcelain and compared it to oven glaze (auto-glaze) by means of roughness and color parameters. Three commercial veneering porcelains with different crystalline content were tested: VM7, VM9, and VM13. Porcelain discs (3.5 × 2.0 mm, diameter × height) were sintered and had one side ground by a diamond bur (45 μm) simulating a chairside adjustment in a clinical office. Specimens (n = 7) were divided into the following groups: C--control (no treatment), G--auto-glaze (oven), and L--surface continuous irradiation with CO2 laser (Gem Laser, Coherent; λ = 10.6 μm). Laser was tested in three exposure times (3, 4, or 5 min) and two irradiances (45 and 50 W/cm(2)). Roughness parameters (Ra, Rz, and Rpm/Rz) were measured using a rugosimeter (Surftest 301, Mitutoyo). Color differences (ΔE) between the G and L groups were calculated (VITA Easyshade); ΔE values up to 3.3 were considered as not perceivable. A surface analysis was conducted by stereomicroscopy (Olympus SZ61) and SEM (Stereoscan 440, LEO). Crystalline content of specimens from groups C and L (50 W/cm(2), 5 min) was assessed by X-ray diffraction and then compared. Surface roughness (Ra and Rz) observed for laser-irradiated groups was similar to G for all studied porcelains. Rpm/Rz ratios were near 1.0 for all groups that indicated a sharp ridge profile for all specimens. Only one laser condition studied (50 W/cm(2), 3 min) from VM7 porcelain resulted in color difference (ΔE = 3.5) to G. Specimens irradiated with 50 W/cm(2) for 5 min presented the smoother surface observed by SEM, comparable to G. X-ray diffraction data revealed an increase in leucite crystallite size for VM9 and VM13 porcelains after laser treatment. Regarding roughness, continuous CO2 laser applied on porcelain surface was as effective as conventional oven auto-glaze.

  16. Reuse of ornamental rock-cutting waste in aluminous porcelain.

    PubMed

    Silva, M A; Paes, H R; Holanda, J N F

    2011-03-01

    Large amounts of solid wastes are discarded in the ornamental rocks industry. This work investigates the incorporation of ornamental rock-cutting waste as a raw material into an aluminous porcelain body, replacing natural feldspar material by up to 35 wt.%. Formulations containing rock-cutting waste were pressed and sintered at 1350 °C. The porcelain pieces were tested to determine their properties (linear shrinkage, water absorption, apparent density, mechanical strength, and electrical resistivity). Development of the microstructure was followed by scanning electron microscopy (SEM) and X-ray diffraction (XRD) analyses. The results showed that ornamental rock-cutting waste could be used in aluminous porcelains, in the range up to 10 wt.%, as a partial replacement for traditional flux material, resulting in a valid route for management of this abundant waste. Copyright © 2010 Elsevier Ltd. All rights reserved.

  17. Effect of chemical composition of Ni-Cr dental casting alloys on the bonding characterization between porcelain and metal.

    PubMed

    Huang, H-H; Lin, M-C; Lee, T-H; Yang, H-W; Chen, F-L; Wu, S-C; Hsu, C-C

    2005-03-01

    The purpose of this study was to investigate the influence of chemical composition of Ni-Cr dental casting alloys on the bonding behaviour between porcelain and metal. A three-point bending test was used to measure the fracture load of alloy after porcelain firing. A scanning electron microscope, accompanied by an energy dispersion spectrometer, was used to analyse the morphology and chemical composition of the fracture surface. An X-ray photoelectron spectrometer and glow discharge spectrometer were used to identify the structure and cross-sectional chemical composition, respectively, of oxide layers on Ni-Cr alloys after heat treatment at 990 degrees C for 5 min. Results showed that the oxide layers formed on all Ni-Cr alloys contained mainly Cr2O3, NiO, and trace MoO3. The Ni-Cr alloy with a higher Cr content had a thicker oxide layer, as well as a weaker bonding behaviour of porcelain/metal interface. The presence of Al (as Al2O3) and Be (as BeO) on the oxide layer suppressed the growth of the oxide layer, leading to a better porcelain/metal bonding behaviour. However, the presence of a small amount of Ti (as TiO2) on the oxide layer did not have any influence on the bonding behaviour. The fracture propagated along the interface between the opaque porcelain and metal, and exhibited an adhesive type of fracture morphology.

  18. The effect of porcelain firing and type of finish line on the marginal fit of zirconia copings.

    PubMed

    Vojdani, Mahroo; Safari, Anahita; Mohaghegh, Mina; Pardis, Soheil; Mahdavi, Farideh

    2015-06-01

    Although all-ceramic restorations are broadly used, there is a lack of information concerning how their fit is affected by fabrication procedure and marginal configuration. The purpose of this study was to evaluate the marginal fit of zirconia CAD/CAM ceramic crowns before and after porcelain firing. The influence of finish line configuration on the marginal fit was also evaluated. Twenty standardized zirconia CAD/CAM copings were fabricated for chamfer and shoulder finish line designs (n=10). The marginal fit of specimens was measured on 18 points, marked on the master metal die by using a digital microscope. After the crowns were finalized by porcelain veneering, the measurements of marginal fit were performed again. The means and standard deviations were calculated and data were analyzed using student's t-test and paired t-test (α=0.05). There were significant differences between marginal fit of chamfer and shoulder finish line groups before and after porcelain firing (p= 0.014 and p= 0.000, respectively). The marginal gap of copings with shoulder finish line was significantly smaller than those with chamfer configuration (p= 0.000), but there were no significant differences between the two marginal designs, after porcelain firing (p= 0.341). Porcelain veneering was found to have a statistically significant influence on the marginal fit of zirconia CAD/CAM crowns. Both margin configurations showed marginal gaps that were within a reported clinically acceptable range of marginal discrepancy.

  19. Distortion of three-unit implant frameworks during casting, soldering, and simulated porcelain firings.

    PubMed

    Zervas, P J; Papazoglou, E; Beck, F M; Carr, A B

    1999-09-01

    The aim of this study was to assess distortion inherent in casting, soldering, and simulated porcelain firings of screw-retained, implant-supported three-unit fixed partial dentures (FPDs). Ten wax patterns were fabricated on a die-stone cast containing two implants, 20 mm apart from center to center. Five specimens were cast in a high-palladium alloy, exposed to simulated porcelain firings, sectioned, and then soldered with low-fusing solder. Five specimens were cast, sectioned, soldered with high-fusing solder, and then exposed to simulated porcelain firings. For each specimen, two horizontal and six vertical distances between appropriately scribed reference points were measured with a traveling microscope. Comparisons were made among the various measurements taken after wax-pattern fabrication, casting, high- and low-fusing soldering, and each porcelain firing. Data were analyzed using a repeated-measures factorial ANOVA (alpha = 0.05). Significant difference was detected in the amount of horizontal distortion during casting (53 +/- 24 microns) and high-fusing soldering (-49 +/- 50 microns), as well as in the amount of horizontal distortion during high-fusing soldering (-49 +/- 50 microns) and low-fusing soldering (17 +/- 26 microns). However, no clinically significant difference was found in the amount of horizontal distortion during casting, low-fusing, and high-fusing soldering. The greatest amount of distortion during the simulated porcelain firings took place during the oxidizing cycle. Soldering did not improve the casting misfit of a three-unit implant-retained FPD model. Metal-ceramic implant frameworks should be oxidized before intraoral fit evaluation.

  20. Clinical performance of porcelain laminate veneers: outcomes of the aesthetic pre-evaluative temporary (APT) technique.

    PubMed

    Gurel, Galip; Morimoto, Susana; Calamita, Marcelo A; Coachman, Christian; Sesma, Newton

    2012-12-01

    This article evaluates the long-term clinical performance of porcelain laminate veneers bonded to teeth prepared with the use of an additive mock-up and aesthetic pre-evaluative temporary (APT) technique over a 12-year period. Sixty-six patients were restored with 580 porcelain laminate veneers. The technique, used for diagnosis, esthetic design, tooth preparation, and provisional restoration fabrication, was based on the APT protocol. The influence of several factors on the durability of veneers was analyzed according to pre- and postoperative parameters. With utilization of the APT restoration, over 80% of tooth preparations were confined to the dental enamel. Over 12 years, 42 laminate veneers failed, but when the preparations were limited to the enamel, the failure rate resulting from debonding and microleakage decreased to 0%. Porcelain laminate veneers presented a successful clinical performance in terms of marginal adaptation, discoloration, gingival recession, secondary caries, postoperative sensitivity, and satisfaction with restoration shade at the end of 12 years. The APT technique facilitated diagnosis, communication, and preparation, providing predictability for the restorative treatment. Limiting the preparation depth to the enamel surface significantly increases the performance of porcelain laminate veneers.

  1. Illustration of compositional variations over time of Chinese porcelain glazes combining micro-X-ray Fluorescence spectrometry, multivariate data analysis and Seger formulas

    NASA Astrophysics Data System (ADS)

    Van Pevenage, J.; Verhaeven, E.; Vekemans, B.; Lauwers, D.; Herremans, D.; De Clercq, W.; Vincze, L.; Moens, L.; Vandenabeele, P.

    2015-01-01

    In this research, the transparent glaze layers of Chinese porcelain samples were investigated. Depending on the production period, these samples can be divided into two groups: the samples of group A dating from the Kangxi period (1661-1722), and the samples of group B produced under emperor Qianlong (1735-1795). Due to the specific sample preparation method and the small spot size of the X-ray beam, investigation of the transparent glaze layers is enabled. Despite the many existing research papers about glaze investigations of ceramics and/or porcelain ware, this research reveals new insights into the glaze composition and structure of Chinese porcelain samples. In this paper it is demonstrated, using micro-X-ray Fluorescence (μ-XRF) spectrometry, multivariate data analysis and statistical analysis (Hotelling's T-Square test) that the transparent glaze layers of the samples of groups A and B are significantly different (95% confidence level). Calculation of the Seger formulas, enabled classification of the glazes. Combining all the information, the difference in composition of the Chinese porcelain glazes of the Kangxi period and the Qianlong period can be demonstrated.

  2. [An experimental research on the fabrication of the fused porcelain to CAD/CAM molar crown].

    PubMed

    Dai, Ning; Zhou, Yongyao; Liao, Wenhe; Yu, Qing; An, Tao; Jiao, Yiqun

    2007-02-01

    This paper introduced the fabrication process of the fused porcelain to molar crown with CAD/CAM technology. Firstly, preparation teeth data was retrieved by the 3D-optical measuring system. Then, we have reconstructed the inner surface designed the outer surface shape with the computer aided design software. Finally, the mini high-speed NC milling machine was used to produce the fused porcelain to CAD/CAM molar crown. The result has proved that the fabrication process is reliable and efficient. The dental restoration quality is steady and precise.

  3. Transapical aortic valve implantation – a rescue procedure for patients with aortic stenosis and “porcelain aorta”

    PubMed Central

    Czerwinska, Katarzyna; Orłowska-Baranowska, Ewa; Witkowski, Adam; Demkow, Marcin; Abramczuk, Elżbieta; Michałek, Piotr; Greszata, Lidia; Stoklosa, Patrycjusz; Kuśmierski, Krzysztof; Kowal, Jaroslaw; Stepinska, Janina

    2011-01-01

    Surgical aortic valve replacement (AVR) still remains the treatment of choice in symptomatic significant aortic stenosis (AS). Due to technical problems, extensive calcification of the ascending aorta (“porcelain aorta”) is an additional risk factor for surgery and transapical aortic valve implantation (TAAVI) is likely to be the only rescue procedure for this group of patients. We describe the case of an 81-year-old woman with severe AS and “porcelain aorta”, in whom the only available life-saving intervention was TAAVI. PMID:22295040

  4. Full-arch milled titanium implant bridge: technical report.

    PubMed

    Peché, Wendy-Ann; Van Vuuren, Ludwig Jansen; Park, Chae

    2011-09-01

    The manufacturing of full-arch fixed implant-supported bridges with the use of the traditional lost wax technique remains a technical challenge. Distortion of the alloy during casting and subsequent heating cycles during porcelain build-up causes numerous problems. Fracturing of porcelain on large restorations is difficult and costly to restore. The fitting problems can be eliminated by utilising CAD/CAM technology in the manufacturing of long-span or full-arch titanium bridges. Repair of damaged porcelain can be simplified with the use of discrete, individually-removable crowns on the bridge.

  5. [Study on the reorganization of standards related to food contact ceramics and porcelains].

    PubMed

    Zhang, Jianbo; Zhu, Lei; Zhang, Hong; Liu, Shan; Wang, Zhutian

    2014-07-01

    To solve the problem of overlap, iterance and conflict among current standards related to food contact ceramics and porcelains. To collect all the current standards related to food contact ceramics and porcelains and reorganize them following the settled principles and method and list the standards that need to be revoked, revised, incorporated, or keep valid and excluded from the food safety standard system. 19 standards were collected in this study and reorganized. The main food safety indexes in these standards were the limits for lead and cadmium that released from food contact ceramics and porcelains. There were released limits for lead and cadmium in 10 standards, including 4 horizontal standards and 6 commodity standards. The provisions in these 10 standards were in conflict. And as a result of this, the 4 horizontal standards were suggested to be incorporated and revised to one food safety standard, while the 6 commodity standards were suggested to be revised and exclude the lead and cadmium provisions. Another 7 commodity standards only referenced provisions for lead and cadmium limits from horizontal standards, and these 7 standards were suggested to be excluded from food safety standard system. There were no food safety indexes in 2 standards of the 19 standards, these standards were considered not related to food safety and no need to be reorganized. There were conflicts about the released limits of lead and cadmium among the current standards related to food contact ceramics and porcelains. So, it is necessary to a set up a new food safety standard for released lead and cadmium permissible limits which can apply to all food contact ceramics and porcelains. This food safety standard should be based on food safety risk assessment and the actual situations of manufacture and usage of food contact ceramics and porcelains. The provisions in international standards and relative standards from other countries can also provide references to this standard.

  6. The Porcelain Crab Transcriptome and PCAD, the Porcelain Crab Microarray and Sequence Database

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tagmount, Abderrahmane; Wang, Mei; Lindquist, Erika

    2010-01-27

    Background: With the emergence of a completed genome sequence of the freshwater crustacean Daphnia pulex, construction of genomic-scale sequence databases for additional crustacean sequences are important for comparative genomics and annotation. Porcelain crabs, genus Petrolisthes, have been powerful crustacean models for environmental and evolutionary physiology with respect to thermal adaptation and understanding responses of marine organisms to climate change. Here, we present a large-scale EST sequencing and cDNA microarray database project for the porcelain crab Petrolisthes cinctipes. Methodology/Principal Findings: A set of ~;;30K unique sequences (UniSeqs) representing ~;;19K clusters were generated from ~;;98K high quality ESTs from a set ofmore » tissue specific non-normalized and mixed-tissue normalized cDNA libraries from the porcelain crab Petrolisthes cinctipes. Homology for each UniSeq was assessed using BLAST, InterProScan, GO and KEGG database searches. Approximately 66percent of the UniSeqs had homology in at least one of the databases. All EST and UniSeq sequences along with annotation results and coordinated cDNA microarray datasets have been made publicly accessible at the Porcelain Crab Array Database (PCAD), a feature-enriched version of the Stanford and Longhorn Array Databases.Conclusions/Significance: The EST project presented here represents the third largest sequencing effort for any crustacean, and the largest effort for any crab species. Our assembly and clustering results suggest that our porcelain crab EST data set is equally diverse to the much larger EST set generated in the Daphnia pulex genome sequencing project, and thus will be an important resource to the Daphnia research community. Our homology results support the pancrustacea hypothesis and suggest that Malacostraca may be ancestral to Branchiopoda and Hexapoda. Our results also suggest that our cDNA microarrays cover as much of the transcriptome as can reasonably be captured in EST library sequencing approaches, and thus represent a rich resource for studies of environmental genomics.« less

  7. [Clinical study of the application of non-invasive porcelain veneer to improve the aesthetic effects in maxillary anterior area].

    PubMed

    Li, Jian-hui; DI, Ping; Hu, Xiu-lian; Qiu, Li-xin; Cui, Hong-yan; Lin, Ye

    2010-02-18

    To evaluate the clinical results of application of non-invasive porcelain veneer to reduce the black triangle of implant and adjacent teeth and to improve the aesthetic effect in the maxillary anterior area. The study included 10 patients (Male: 4, Female: 6; average age: 41.5) accessioned during May 2007 to August 2009 in Peking University School of Stomatology. The provisional restorations were delivery on implant after 3-6 months healing period of the implant. The non-invasive porcelain veneers were used in the round tip adjacent teeth with gingival recession in the indicated patients. Main measured parameters on the model included horizontal distance and vertical distance. The Horizontal distance refers to the black triangle bottom which is from adjacent surface of the natural teeth to the implant restoration at the gingival level. The vertical distance is from mid-point of the triangle bottom to the contact point. Clinical observed items included bleeding index (BI), integrity of porcelain veneer and degree of satisfaction of the patients. A total of 14 adjacent natural teeth in 10 patients were cemented with porcelain veneer. No porcelain veneer was lost or fracture during follow-up period (range 6 to 27 months, mean of 10.4 months). Mean bleeding index 0-1. The horizontal distance was reduced from (3.1 + or - 0.8) mm before restoration to (1.1 + or - 0.5) mm after restoration. Vertical distance from (5.3 + or - 1.1) mm to (2.9 + or - 0.7) mm. All patients were satisfied with the clinical result. The data and the experience described in this study indicate that improvement of aesthetic effects by using no-invasive porcelain veneer techniques can be a predictable technique for patients with periodontal disease. Further study is needed to determine the long-term result of the technique.

  8. A historical perspective of synthetic ceramic and traditional feldspathic porcelain.

    PubMed

    Chu, Stephen; Ahmad, Irfan

    2005-10-01

    Ceramics were invented by the Chinese during the T'ang Dynasty, where they quickly became a precious commodity. By the early 18th Century, ceramics found its way into dentistry due to its high strength, biocompatibility, and malleability. Today, ceramic materials are a staple in dentistry, available in both naturally based and partially synthetic formulas. Most recently they have become available as quartz-glass synthetic materials manufactured under controlled conditions to eliminate the inconsistencies and impurities inherent in the naturally based counterpart. This article details the discovery of porcelain and its role as a precious substance throughout the world and time, from its initial use as ornamental earthenware to its practical application in modern dentistry. Upon reading this article, the reader should: Understand the historical significance of porcelain. Recognize the fundamental constituents and physical properties of both natural feldspathic porcelains and fully synthetic ceramics used in dentistry.

  9. Some new results of PIXE study on Chinese ancient porcelain

    NASA Astrophysics Data System (ADS)

    Cheng, H. S.; Zhang, B.; Zhu, D.; Yang, F. J.; Sun, X. M.; Guo, M. S.

    2005-10-01

    This paper reports some new results obtained by PIXE on Chinese ancient porcelain. The first results concern the provenance of blue and white porcelain made during the Tang Dynasty (AD618-907), which are the earliest products found in China. The PIXE experimental results show that they were fired in Huangye Kiln, Gongyi, Henan Province. The chemical composition of the body, white glaze and of the cobalt pigment will be reported. This paper also reports the results for early Chinese blue and white porcelain made under the Yuan dynasty (AD1206-1368) in Jingdezhen, Jiangxi Province. Experimental results show that the chemical composition of the cobalt pigment used by officers and popular are similar. These materials were imported from another country. The local asbolite was used as cobalt pigment material since the early Ming Dynasty (AD1368-1644) in Jingdezhen at folk kiln, and it was used at official kiln until the 16th century.

  10. Evaluation of Candida albicans formation on feldspathic porcelain subjected to four surface treatment methods.

    PubMed

    Karayazgan, Banu; Atay, Arzu; Saracli, Mehmet Ali; Gunay, Yumushan

    2010-03-01

    Candida albicans, known for its adhesion on prosthetic materials and oral tissues, is the most frequently encountered fungal infection in dentistry. The aim of this study was to evaluate the effects of four different surface treatment methods and immersion in artificial saliva on the surface roughness of and candida adhesion on dental porcelains. The four surface treatment methods were namely: natural glaze, overglaze, dual ion exchange, and polishing. Surface roughness of porcelain was evaluated using a surface profilometer and by SEM. Candida adhesion was examined by culturing two Candida strains on porcelain specimens followed by a colorimetric method using XTT/Coenzyme Q0. It became evident that Candida adhesion was found more in the specimens treated with natural glaze and polishing. Further, by the visual inspection of SEM images and comparison of surface roughness, polished and natural-glazed specimens showed rougher surface characteristics than overglazed and dual-ion-exchanged specimens.

  11. Porcelain surface alterations and refinishing after use of two orthodontic bonding methods.

    PubMed

    Herion, Drew T; Ferracane, Jack L; Covell, David A

    2010-01-01

    To compare porcelain surfaces at debonding after use of two surface preparation methods and to evaluate a method for restoring the surface. Lava Ceram feldspathic porcelain discs (n = 40) underwent one of two surface treatments prior to bonding orthodontic brackets. Half the discs had sandblasting, hydrofluoric acid, and silane (SB + HF + S), and the other half, phosphoric acid and silane (PA + S). Brackets were debonded using bracket removing pliers, and resin was removed with a 12-fluted carbide bur. The surface was refinished using a porcelain polishing kit, followed by diamond polishing paste. Measurements for surface roughness (Ra), gloss, and color were made before bonding (baseline), after debonding, and after each step of refinishing. Surfaces were also examined by scanning electron microscopy (SEM). Data was analyzed with 2-way ANOVA followed by Tukey HSD tests (alpha = 0.05). The SB + HF + S bonding method increased Ra (0.160 to 1.121 microm), decreased gloss (41.3 to 3.7) and altered color (DeltaE = 4.37; P < .001). The PA + S method increased Ra (0.173 to 0.341 microm; P < .001), but the increase in Ra was significantly less than that caused by the SB + HF + S bonding method (P < . 001). The PA + S method caused insignificant changes in gloss (41.7 to 38.0) and color (DeltaE = 0.50). The measurements and SEM observations showed that changes were fully restored to baseline with refinishing. The PA + S method caused significantly less damage to porcelain than the SB + HF + S method. The refinishing protocol fully restored the porcelain surfaces.

  12. Influence of tempering and contraction mismatch on crack development in ceramic surfaces.

    PubMed

    Anusavice, K J; DeHoff, P H; Hojjatie, B; Gray, A

    1989-07-01

    Tempering of glass produces a state of compressive stress in surface regions which can enhance the resistance to crack initiation and growth. The objective of this study was to determine the influence of tempering on the sizes of surface cracks induced within the tempered surfaces of opaque porcelain-body porcelain discs, with contraction coefficient differences (alpha O-alpha B) of +3.2, +0.7, 0.0, -0.9, and -1.5 ppm/degrees C. We fired the discs to the maturing temperature (982 degrees C) of body porcelain and then subjected them to three cooling procedures: slow cooling in a furnace (SC), fast cooling in air (FC), and tempering (T) by blasting the body porcelain surface with compressed air for 90 s. We used body porcelain discs as the thermally compatible (delta alpha = 0) control specimens. We measured the diameters of cracks induced by a microhardness indenter at an applied load of 4.9 N at 80 points along diametral lines within the surface of body porcelain. The mean values of the crack diameters varied from 75.9 microns (delta alpha = -1.5 ppm/degrees C) to 103.3 microns (delta alpha = +3.2 ppm/degrees C). The results of ANOVA indicate that significant differences in crack dimensions were controlled by cooling rate, contraction mismatch, and their combined effect (p less than 0.0001). Multiple contrast analysis (Tukey's HSD Test) revealed significantly lower (p less than 0.05) crack sizes for tempered specimens compared with those of fast-cooled and slow-cooled specimens.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Using glass-graded zirconia to increase delamination growth resistance in porcelain/zirconia dental structures.

    PubMed

    Chai, Herzl; Mieleszko, Adam J; Chu, Stephen J; Zhang, Yu

    2018-01-01

    Porcelain fused to zirconia (PFZ) restorations are widely used in prosthetic dentistry. However, their tendency to delaminate along the P/Z interface remains a practical problem so that assessing and improving the interfacial strength are important design aspects. This work examines the effect of modifying the zirconia veneering surface with an in-house felspathic glass on the interfacial fracture resistance of fused P/Z. Three material systems are studied: porcelain fused to zirconia (control) and porcelain fused to glass-graded zirconia with and without the presence of a glass interlayer. The specimens were loaded in a four-point-bend fixture with the porcelain veneer in tension. The evolution of damage is followed with the aid of a video camera. The interfacial fracture energy G C was determined with the aid of a FEA, taking into account the stress shielding effects due to the presence of adjacent channel cracks. Similarly to a previous study on PFZ specimens, the fracture sequence consisted of unstable growth of channel cracks in the veneer followed by stable cracking along the P/Z interface. However, the value of GC for the graded zirconia was approximately 3 times that of the control zirconia, which is due to the good adhesion between porcelain and the glass network structure on the zirconia surface. Combined with its improved bonding to resin-based cements, increased resistance to surface damage and good esthetic quality, graded zirconia emerges as a viable material concept for dental restorations. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. The Effect of Porcelain Firing and Type of Finish Line on the Marginal Fit of Zirconia Copings

    PubMed Central

    Vojdani, Mahroo; Safari, Anahita; Mohaghegh, Mina; Pardis, Soheil; Mahdavi, Farideh

    2015-01-01

    Statement of the Problem Although all-ceramic restorations are broadly used, there is a lack of information concerning how their fit is affected by fabrication procedure and marginal configuration. Purpose The purpose of this study was to evaluate the marginal fit of zirconia CAD/CAM ceramic crowns before and after porcelain firing. The influence of finish line configuration on the marginal fit was also evaluated. Materials and Method Twenty standardized zirconia CAD/CAM copings were fabricated for chamfer and shoulder finish line designs (n=10). The marginal fit of specimens was measured on 18 points, marked on the master metal die by using a digital microscope. After the crowns were finalized by porcelain veneering, the measurements of marginal fit were performed again. The means and standard deviations were calculated and data were analyzed using student’s t-test and paired t-test (α=0.05). Results There were significant differences between marginal fit of chamfer and shoulder finish line groups before and after porcelain firing (p= 0.014 and p= 0.000, respectively). The marginal gap of copings with shoulder finish line was significantly smaller than those with chamfer configuration (p= 0.000), but there were no significant differences between the two marginal designs, after porcelain firing (p= 0.341). Conclusion Porcelain veneering was found to have a statistically significant influence on the marginal fit of zirconia CAD/CAM crowns. Both margin configurations showed marginal gaps that were within a reported clinically acceptable range of marginal discrepancy. PMID:26046107

  15. Influence of leucite content on slow crack growth of dental porcelains.

    PubMed

    Cesar, Paulo F; Soki, Fabiana N; Yoshimura, Humberto N; Gonzaga, Carla C; Styopkin, Victor

    2008-08-01

    To determine the stress corrosion susceptibility coefficient, n, of seven dental porcelains (A: Ceramco I; B: Ceramco-II; C: Ceramco-III; D: d.Sign; E: Cerabien; F: Vitadur-Alpha; and G: Ultropaline) after aging in air or artificial saliva, and correlate results with leucite content (LC). Bars were fired according to manufacturers' instructions and polished before induction of cracks by a Vickers indenter (19.6N, 20s). Four specimens were stored in air/room temperature, and three in saliva/37 degrees C. Five indentations were made per specimen and crack lengths measured at the following times: approximately 0; 1; 3; 10; 30; 100; 300; 1000 and 3000 h. The stress corrosion coefficient n was calculated by linear regression analysis after plotting crack length as a function of time, considering that the slope of the curve was [2/(3n+2)]. Microstructural analysis was performed to determine LC. LC of the porcelains were 22% (A and B); 6% (C); 15% (D); 0% (E and F); and 13% (G). Except for porcelains A and D, all materials showed a decrease in their n values when stored in artificial saliva. However, the decrease was more pronounced for porcelains B, F, and G. Ranking of materials varied according to storage media (in air, porcelain G showed higher n compared to A, while in saliva both showed similar coefficients). No correlation was found between n values and LC in air or saliva. Storage media influenced the n value obtained for most of the materials. LC did not affect resistance to slow crack growth regardless of the test environment.

  16. Low absorptance porcelain-on-aluminum coating

    NASA Technical Reports Server (NTRS)

    Leggett, H.

    1979-01-01

    Porcelain thermal-control coating for aluminum sheet and foil has solar absorptance of 0.22. Specially formulated coating absorptance is highly stable, changing only 0.03 after 1,000 hours of exposure to simulated sunlight and can be applied by standard commercial methods.

  17. PIXE analysis of ancient Chinese Changsha porcelain

    NASA Astrophysics Data System (ADS)

    Lin, E. K.; Yu, Y. C.; Wang, C. W.; Liu, T. Y.; Wu, C. M.; Chen, K. M.; Lin, S. S.

    1999-04-01

    In this work, proton induced X-ray emission (PIXE) method was applied for the analysis of ancient Chinese Changsha porcelain produced in the Tang dynasty (AD 618-907). A collection of glazed potsherds was obtained in the complex of the famous kiln site at Tongguan, Changsha city, Hunan province. Studies of elemental composition were carried out on ten selected Changsha potsherds. Minor and trace elements such as Ti, Mn, Fe, Co, Cu, Rb, Sr, and Zr in the material of the porcelain glaze were determined. Variation of these elements from sample to sample was investigated. Details of results are presented and discussed.

  18. Esthetic restorations of maxillary anterior teeth with orthodontic treatment and porcelain laminate veneers: a case report.

    PubMed

    Moon, Ji-Eun; Kim, Sung-Hun; Han, Jung-Suk; Yang, Jae-Ho; Lee, Jai-Bong

    2010-06-01

    If orthodontists and restorative dentists establish the interdisciplinary approach to esthetic dentistry, the esthetic and functional outcome of their combined efforts will be greatly enhanced. This article describes satisfying esthetic results obtained by the distribution of space for restoration by orthodontic treatment and porcelain laminate veneers in uneven space between maxillary anterior teeth. It is proposed that the use of orthodontic treatment for re-distribution of the space and the use of porcelain laminate veneers to alter crown anatomy provide maximum esthetic and functional correction for patients with irregular interdental spacing.

  19. A Preliminary Research into Clinical Semi-permeability Tolerance in the Field of Dental Rehabilitation

    PubMed Central

    Xia, H; Xiong, F

    2015-01-01

    ABSTRACT Objective: To study clinical semi-permeability tolerance level in the field of dental restoration. Method: Vita 95 enamel porcelain powder was adopted and 6.0% used as the control transmissivity. Discoid porcelain plates with different transmissivity, namely increasing transmissivity (0.25%, 0.5%, 1.0%, 1.5%, 2%, 2.5%, 3%, 3.5%, 4% and 4.5%) and decreasing transmissivity (-0.25%, −0.5%, −1.0%, −1.5%, −2%, −2.5%, −3% and −3.5%) were made. Forty observers judged these according to six grades: same, similar, slightly different, visibly different, recognizable and significantly different, and under the observation conditions of a neutral grey background and 45°/0° lighting. The judgment results were analysed statistically. Results: When the transmissivity of the control porcelain plates was 6.032%, and the transmissivity of test porcelain plates decreased by 1% or increased by 3%, observers could find slight differences between the test samples and the control samples. When transmissivity of test samples decreased by 2.5% or increased by 4.5%, observers thought that the two porcelain plates belonged to different orders of magnitude. Conclusions: Under the experimental conditions, the upper and lower limits of clinical semi-permeability tolerance were 3% and 1%, respectively. PMID:27400057

  20. [Effect of Ti bonder on the bond strength between porcelain and titanium].

    PubMed

    Yao, Hai; Luo, Xiao-ping

    2009-12-01

    To investigate the influence of GC Initial Ti Bonder on bond strength between Vita Titankeramik porcelain and titanium. Forty titanium samples were prepared and randomly assigned to 4 groups with 10 samples in each group. Samples in each group were subjected to one of the following surface treatments, burnishing (Group B), sandblasting (Group S), firing GC Initial Ti Bonder after burnishing (Group BG) and firing GC Initial Ti Bonder after sandblasting (Group SG). Vita Titankeramik porcelain were fired on the surface of each sample in the middle. Three-point bending tests were conducted on each sample according to the ISO 9693. The fracture patterns of all specimens were recorded using zoom stereo microscope (ZSM) and the fracture surfaces were observed under scanning electron microscope (SEM). With fired GC Initial Ti Bonder, the bond strength of Vita Titankeramik porcelain to titanium in Group BG and Group SG were (32.72 +/- 4.46) and (34.25 +/- 6.52) MPa respectively, which reach the ISO 9693 standard for clinical use and were significantly higher than those in Group B [(20.70 +/- 3.15) MPa] and Group S [(23.92 +/- 5.02) MPa]. GC Initial Ti Bonder can significantly improve bond strength between Vita Titankeramik porcelain and titanium.

  1. Study on the property of the production for Fengdongyan kiln in Early Ming dynasty by INAA and EDXRF

    NASA Astrophysics Data System (ADS)

    Li, L.; Huang, Y.; Sun, H. Y.; Yan, L. T.; Feng, S. L.; Xu, Q.; Feng, X. Q.

    2016-08-01

    A lot of official wares carved "Guan" or the dragon patterns were excavated on the strata of Ming dynasty of the Fengdongyan kiln site at Dayao County. The imperial porcelain was fired in Hongwu and Yongle eras. However, the emergence of this imperial porcelain has triggered academic debate about the property of Fengdongyan kiln in the Early Ming dynasty. Based on the differences of the official kiln management, some scholars have determined that the property of the production for this kiln was the civilian kiln. According to the historical textural records and typology, others preliminary confirmed that Fengdongyan kiln was the official kiln. In this paper, the elemental compositions of body and glaze in imperial and civilian porcelain are study by INAA and EDXRF for determining the property of the production for this kiln in Early Ming dynasty. After the processing of experimental data by geochemical analysis and principal component analysis, the result show that the raw materials for making body and glaze in imperial porcelain are similar with those of the civilian porcelain and the degrees of elutriation for body can be slightly different in HW-M period of Ming dynasty. The analytical results support the view that the Fengdongyan kiln is civilian not official.

  2. Letters from China: A History of the Origins of the Chemical Analysis of Ceramics.

    PubMed

    Pollard, A M

    2015-02-01

    This paper is an attempt to document the early history of the quantitative chemical analysis of ceramic materials in Europe, with a specific interest in the analysis of archaeological ceramics. This inevitably leads to a study of the attempts made in Europe to imitate the miraculous material--porcelain--imported from China from the fourteenth century onwards. It is clear that before the end of the eighteenth century progress was made in this endeavor by systematic but essentially trial-and-error firing of various raw materials, culminating in the successful production of European porcelain by Böttger and von Tschirnhaus in 1709. Shortly after this, letters describing the Chinese manufacture of porcelain, and, more importantly, samples of raw and fired material, began to arrive in Europe from French Jesuit missionaries, which were subjected to intense study. Following the perfection of gravimetric methods of chemical analysis in the late eighteenth century, these Chinese samples, and samples of porcelain from various European factories, were regularly analysed, particularly by Brongniart at Sèvres. Similar work was carried out on English porcelain by Simeon Shaw and Sir Arthur Church. The origins of the chemical analysis of archaeological ceramics are still somewhat obscure, but must date to the late eighteenth or early nineteenth centuries, by the likes of Vauquelin and Chaptal.

  3. Reuse of solid petroleum waste in the manufacture of porcelain stoneware tile.

    PubMed

    Pinheiro, B C A; Holanda, J N F

    2013-03-30

    This study investigates the incorporation of solid petroleum waste as raw material into a porcelain stoneware tile body, in replacement to natural kaolin material by up to 5 wt.%. Tile formulations containing solid petroleum waste were pressed and fired at 1240 °C by using a fast-firing cycle. The tile pieces were tested to determine their properties (linear shrinkage, water absorption, apparent density, and flexural strength), sintered microstructure, and leaching toxicity. The results therefore indicated that the growing addition of solid petroleum waste into tile formulations leads to a decrease of linear shrinkage, apparent density, and flexural strength, and to an increase of water absorption of the produced tile materials. It was also found that the replacement of kaolin with solid petroleum waste, in the range up to 2.5 wt.%, allows the production of porcelain stoneware tile (group BIa, ISO 13006 standard). All concentrations of Ag, As, Ba, Cd, Cr (total), Hg, and Pb of the fired porcelain stoneware tile pieces in the leachate comply with the current regulatory limits. These results indicate that the solid petroleum waste could be used for high-quality porcelain stoneware tile production, thus giving rise to a new possibility for an environmentally friendly management of this abundant waste. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Comparison of the metal-to-ceramic bond strengths of four noble alloys with press-on-metal and conventional porcelain layering techniques.

    PubMed

    Khmaj, Mofida R; Khmaj, Abdulfatah B; Brantley, William A; Johnston, William M; Dasgupta, Tridib

    2014-11-01

    New noble alloys for metal ceramic restorations introduced by manufacturers are generally lower-cost alternatives to traditional higher-gold alloys. Information about the metal-to-ceramic bond strength for these alloys, which is needed for rational clinical selection, is often lacking. The purpose of this study was to evaluate the bond strength of 4 recently introduced noble alloys by using 2 techniques for porcelain application. Aquarius Hard (high-gold: 86.1 gold, 8.5 platinum, 2.6 palladium, 1.4 indium; values in wt. %), Evolution Lite (reduced-gold: 40.3 gold, 39.3 palladium, 9.3 indium, 9.2 silver, 1.8 gallium), Callisto 75 Pd (palladium-silver containing gold: 75.2 palladium, 7.1 silver, 2.5 gold, 9.3 tin, 1.0 indium), and Aries, (conventional palladium-silver: 63.7 palladium, 26.0 silver, 7.0 tin, 1.8 gallium, 1.5 indium) were selected for bonding to leucite-containing veneering porcelains. Ten metal ceramic specimens that met dimensional requirements for International Organization for Standardization (ISO) Standard 9693 were prepared for each alloy by using conventional porcelain layering and press-on-metal methods. The 3-point bending test in ISO Standard 9693 was used to determine bond strength. Values were compared with 2-way ANOVA (maximum likelihood analysis, SAS Mixed Procedure) and the Tukey test (α=.05). Means (standard deviations) for bond strength with conventional porcelain layering were as follows: Aquarius Hard (50.7 ±5.5 MPa), Evolution Lite (40.2 ±3.3 MPa), Callisto 75 Pd (37.2 ±3.9 MPa), and Aries (34.0 ±4.9 MPa). For the press-on-metal technique, bond strength results were as follows: Aquarius Hard (33.7 ±11.5 MPa), Evolution Lite (34.9 ±4.5 MPa), Callisto 75 Pd (37.2 ±11.9 MPa), and Aries (30.7 ±10.8 MPa). From statistical analyses, the following 3 significant differences were found for metal-to-ceramic bond strength: the bond strength for Aquarius Hard was significantly higher for conventional porcelain layers compared with the press-on-metal technique; the bond strength for Aquarius Hard with conventional porcelain layers was significantly higher than the bond strengths for the other 3 alloys with conventional porcelain layers; and the bond strength for Aquarius Hard with conventional porcelain layers was significantly higher than the bond strength for Callisto 75 Pd with conventional porcelain layers and the other 3 alloys with the press-on-metal technique. For both conventional layering and press-on-metal techniques, all 4 noble alloys had a mean metal-to-ceramic bond strength that substantially exceeded the 25 MPa minimum in the ISO Standard 9693. The results for Aries support the manufacturer's recommendation not to use the press-on-metal technique for alloys that contain more than 10% silver. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  5. Evaluating the Whitening and Microstructural Effects of a Novel Whitening Strip on Porcelain and Composite Dental Materials

    PubMed Central

    Takesh, Thair; Sargsyan, Anik; Lee, Matthew; Anbarani, Afarin; Ho, Jessica; Wilder-Smith, Petra

    2017-01-01

    Aims The aim of this project was to evaluate the effects of 2 different whitening strips on color, microstructure and roughness of tea stained porcelain and composite surfaces. Methods 54 porcelain and 72 composite chips served as samples for timed application of over-the-counter (OTC) test or control dental whitening strips. Chips were divided randomly into three groups of 18 porcelain and 24 composite chips each. Of these groups, 1 porcelain and 1 composite set served as controls. The remaining 2 groups were randomized to treatment with either Oral Essentials® Whitening Strips or Crest® 3D White Whitestrips™. Sample surface structure was examined by light microscopy, profilometry and Scanning Electron Microscopy (SEM). Additionally, a reflectance spectrophotometer was used to assess color changes in the porcelain and composite samples over 24 hours of whitening. Data points were analyzed at each time point using ANOVA. Results In the light microscopy and SEM images, no discrete physical defects were observed in any of the samples at any time points. However, high-resolution SEM images showed an appearance of increased surface roughness in all composite samples. Using profilometry, significantly increased post-whitening roughness was documented in the composite samples exposed to the control bleaching strips. Composite samples underwent a significant and equivalent shift in color following exposure to Crest® 3D White Whitestrips™ and Oral Essentials® Whitening Strips. Conclusions A novel commercial tooth whitening strip demonstrated a comparable beaching effect to a widely used OTC whitening strip. Neither whitening strip caused physical defects in the sample surfaces. However, the control strip caused roughening of the composite samples whereas the test strip did not. PMID:29226023

  6. Comparative Evaluation of Effects of Laser Modalities on Shear Bond Strengths of Veneering Porcelains to Laser Sintered Substructures: An In Vitro Study.

    PubMed

    Gorler, Oguzhan; Saygin, Aysegul Goze

    2017-06-01

    Laser modalities and direct metal laser sintering (DMLS) have a potential to enhance micromechanical bonding between dental super- and infrastructures. However, the effect of different manufacturing methods on the metal-ceramic bond strength needs further evaluation. We investigated the effect of surface treatment with Er:YAG, Nd:YAG, and Ho:YAG lasers on the shear bond strength (SBS) of high-fusion dental porcelains (Vita and G-Ceram) to infrastructures prepared with DMLS in vitro settings. Study specimens (n = 128) were randomly divided into study subsets (n = 8), considering treatment types applied on the surface of infrastructures, including sandblasting and selected laser modalities; infrastructure types as direct laser sintered (DLS) and Ni-Cr based; and superstructure porcelains as Vita and G-Ceram. The SBS test was performed to assess the effectiveness of surface modifications that were also examined with a stereo microscope. Considering laser procedure types, the highest SBS values were obtained by Er:YAG laser, followed by, with a decreasing efficiency, Ho:YAG laser and sandblasting procedures, and Nd:YAG laser procedure (p < 0.05). Nd:YAG laser decreases the bonding of Vita and G-Ceram in all the infrastructures compared with sandblasting. Considering porcelains, the highest SBS values were obtained by Vita (p < 0.05). Considering infrastructures, the highest SBS values were obtained by DMLS procedure (p < 0.05). The laser procedures caused surface irregularities as revealed by the stereo microscopic examination. In current experimental settings, Er:YAG laser applied to DLS infrastructure veneered with Vita porcelain increases bonding strength more distinctly, and Nd:YAG laser applied to Ni-Cr-based infrastructure veneered with G-Ceram porcelain alters bonding strength unfavorably.

  7. Viscoelastic finite element analysis of residual stresses in porcelain-veneered zirconia dental crowns.

    PubMed

    Kim, Jeongho; Dhital, Sukirti; Zhivago, Paul; Kaizer, Marina R; Zhang, Yu

    2018-06-01

    The main problem of porcelain-veneered zirconia (PVZ) dental restorations is chipping and delamination of veneering porcelain owing to the development of deleterious residual stresses during the cooling phase of veneer firing. The aim of this study is to elucidate the effects of cooling rate, thermal contraction coefficient and elastic modulus on residual stresses developed in PVZ dental crowns using viscoelastic finite element methods (VFEM). A three-dimensional VFEM model has been developed to predict residual stresses in PVZ structures using ABAQUS finite element software and user subroutines. First, the newly established model was validated with experimentally measured residual stress profiles using Vickers indentation on flat PVZ specimens. An excellent agreement between the model prediction and experimental data was found. Then, the model was used to predict residual stresses in more complex anatomically-correct crown systems. Two PVZ crown systems with different thermal contraction coefficients and porcelain moduli were studied: VM9/Y-TZP and LAVA/Y-TZP. A sequential dual-step finite element analysis was performed: heat transfer analysis and viscoelastic stress analysis. Controlled and bench convection cooling rates were simulated by applying different convective heat transfer coefficients 1.7E-5 W/mm 2 °C (controlled cooling) and 0.6E-4 W/mm 2 °C (bench cooling) on the crown surfaces exposed to the air. Rigorous viscoelastic finite element analysis revealed that controlled cooling results in lower maximum stresses in both veneer and core layers for the two PVZ systems relative to bench cooling. Better compatibility of thermal contraction coefficients between porcelain and zirconia and a lower porcelain modulus reduce residual stresses in both layers. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. A Comparison between Shear Bond Strength of VMK Master Porcelain with Three Base-metal Alloys (Ni-cr-T3, VeraBond, Super Cast) and One Noble Alloy (X-33) in Metal-ceramic Restorations

    PubMed Central

    Ahmadzadeh, A; Neshati, A; Mousavi, N; Epakchi, S; Dabaghi Tabriz, F; Sarbazi, AH

    2013-01-01

    Statement of Problem: The increase in the use of metal-ceramic restorations and a high prevalence of porcelain chipping entails introducing an alloy which is more compatible with porcelain and causes a stronger bond between the two. This study is to compare shear bond strength of three base-metal alloys and one noble alloy with the commonly used VMK Master Porcelain. Materials and Method: Three different groups of base-metal alloys (Ni-cr-T3, Super Cast, and VeraBond) and one group of noble alloy (X-33) were selected. Each group consisted of 15 alloy samples. All groups went through the casting process and change from wax pattern into metal disks. The VMK Master Porcelain was then fired on each group. All the specimens were put in the UTM; a shear force was loaded until a fracture occurred and the fracture force was consequently recorded. The data were analyzed by SPSS Version 16 and One-Way ANOVA was run to compare the shear strength between the groups. Furthermore, the groups were compared two-by-two by adopting Tukey test. Results: The findings of this study revealed shear bond strength of Ni-Cr-T3 alloy was higher than the three other alloys (94 MPa or 330 N). Super Cast alloy had the second greatest shear bond strength (80. 87Mpa or 283.87 N). Both VeraBond (69.66 MPa or 245 N) and x-33 alloys (66.53 MPa or 234 N) took the third place. Conclusion: Ni-Cr-T3 with VMK Master Porcelain has the greatest shear bond strength. Therefore, employment of this low-cost alloy is recommended in metal-ceramic restorations. PMID:24724144

  9. Effect of different aging methods on the mechanical behavior of multi-layered ceramic structures.

    PubMed

    Borba, Márcia; de Araújo, Maico D; Fukushima, Karen A; Yoshimura, Humberto N; Griggs, Jason A; Della Bona, Álvaro; Cesar, Paulo F

    2016-12-01

    To evaluate the effect of two aging methods (mechanical cycling and autoclave) on the mechanical behavior of veneer and framework ceramic specimens with different configurations (monolithic, two and three-layers). Three ceramics used as framework for fixed dental prostheses (YZ-Vita In-Ceram YZ; IZ-Vita In-Ceram Zirconia; AL-Vita In-Ceram AL) and two veneering porcelains (VM7 and VM9) were studied. Bar-shaped specimens were produced in three different designs: monolithic, two layers (porcelain-framework) and three layers (porcelain-framework-porcelain). Specimens were tested for three-point flexural strength at 1MPa/s in 37°C artificial saliva. Three different experimental conditions were evaluated (n=10): control; mechanical cycling (2Hz, 37°C artificial saliva); and autoclave aging (134°C, 2 bars, 5h). Bi-layered specimens were tested in both conditions: with porcelain or framework ceramic under tension. Fracture surfaces were analyzed using stereomicroscope and scanning electron microscopy. Results were statistically analyzed using Kruskal-Wallis and Student-Newman-Keuls tests. Only for AL group, mechanical cycling and autoclave aging significantly decreased the flexural strength values in comparison to the control (p<0.01). YZ, AL, VM7 and VM9 monolithic groups showed no strength degradation. For multi-layered specimens, when the porcelain layer was tested in tension (bi and tri-layers), the aging methods evaluated also had no effect on strength (p≥0.05). Total and partial failure modes were identified. Mechanical cycling and autoclave aging protocols had no effect on the flexural strength values and failure behavior of YZ and IZ ceramic structures. Yet, AL monolithic structures showed a significant decrease in flexural strength with any of the aging methods. Copyright © 2016. Published by Elsevier Ltd.

  10. Influence of ultraviolet irradiation treatment on porcelain bond strength of titanium surfaces.

    PubMed

    Kumasaka, Tomonari; Ohno, Akinori; Hori, Norio; Hoshi, Noriyuki; Maruo, Katsuichiro; Kuwabara, Atsushi; Seimiya, Kazuhide; Toyoda, Minoru; Kimoto, Katsuhiko

    2018-01-26

    To determine the effect of titanium (Ti) surface modification by ultraviolet irradiation (UVI) on the bond strength between Ti and porcelain. Grade 2 Ti plates were allotted to five groups: sandblasted (SA), 15 min UVI (UV), SA+5 min UVI (SA+UV5), SA+10 min UVI (SA+UV10), and SA+15 min UVI (SA+UV15). After surface treatment, porcelain was added. A precious metal (MC) was used for comparison with Ti. The effects of 24-h storage at room temperature versus thermal cycling only at 5 and 55°C in water were evaluated. Subsequently, the tensile strength of each sample was tested. Data were analyzed using one-way analysis of variance and the Tukey test. In both the room temperature and thermal cycling groups, the MC and SA+15 min UVI samples showed significantly greater bond strengths than the other samples (p<0.05). UVI processing efficiently increases the bond strength between porcelain and the Ti surface.

  11. Effect of ice-quenching on the change in hardness of a Pd-Au-Zn alloy during porcelain firing simulation.

    PubMed

    Shin, Hye-Jeong; Kim, Min-Jung; Kim, Hyung-Il; Kwon, Yong Hoon; Seol, Hyo-Joung

    2017-03-31

    This study examined the effect of ice-quenching after degassing on the change in hardness of a Pd-Au-Zn alloy during porcelain firing simulations. By ice-quenching after degassing, the specimens were softened due to homogenization without the need for an additional softening heat treatment. The lowered hardness by ice-quenching after degassing was recovered greatly from the first stage of porcelain firing process by controlling the cooling rate. The increase in hardness during cooling after porcelain firing was attributed to the precipitation of the f.c.t. PdZn phase containing Au, which caused severe lattice strain in the interphase boundary between the precipitates and matrix of the f.c.c. structure. The final hardness was slightly higher in the ice-quenched specimen than in the specimen cooled at stage 0 (the most effective cooling rate for alloy hardening) after degassing. This was attributed to the more active grain interior precipitation during cooling in the ice-quenched specimen after degassing.

  12. Microshear bond strength of composite resins to enamel and porcelain substrates utilizing unfilled versus filled resins.

    PubMed

    Najafi-Abrandabadi, Ahmad; Najafi-Abrandabadi, Siamak; Ghasemi, Amir; Kotick, Philip G

    2014-11-01

    Failures such as marginal discoloration and composite chipping are still the problems of tooth-colored restorations on the substrate of enamel and porcelain, which some of these problems are consequently as a result of failures in the bonding layer. Using filled resin has been recently introduced to increase the bond strength of this layer. The aim of this study was to compare the microshear bond strength (μ-SBS) of composite resins to enamel incubated in periods of 24 h and 9 months and porcelain with unfilled resin and flowable composites (filled resin). In this in vitro study, two groups of 75 enamel samples with different storage times (24 h and 9 months) and a group of 75 porcelain samples were used. They were divided into 5 experimental groups of 15 samples in each. Composite cylinders in tygon tubes were bonded on the surface of acid-etched enamel and pretreated porcelain. Wave, Wave MV, Wave HV, Grandioflow and Margin Bond were used as bonding agents. The μ-SBS was measured at the speed of 1.0 mm/min. The bond strengths were analyzed with one-way analysis of variance (ANOVA) test followed by Tukey test. P < 0.05 was selected as the level of statistical significance in this study. The results showed that for enamel (24 h), the μ-SBS of the Wave MV and Wave HV groups were significantly lower than the Margin Bond group. Tukey test indicated the absence of a significant difference between the μ-SBS of the Wave group and the Margin Bond group. However, the μ-SBS of the Grandioflow group was significantly higher than the one for the Margin Bond as a bonding agent. In enamel (9 months), there was a significant difference between the Grandioflow and Margin Bond groups. Regarding bonding to the porcelain the one-way ANOVA test did not show a significant difference among the groups. This study revealed that flowable composites (filled resins) can be used instead of unfilled resins in bonding composite resins to enamel and porcelain substrates.

  13. Percutaneous Implantation of the self-expanding valve Prosthesis a patient with homozygous familial hypercholesterolemia severe aortic stenosis and porcelain aorta.

    PubMed

    Sahiner, Levent; Asil, Serkan; Kaya, Ergün Baris; Ozer, Necla; Aytemir, Kudret

    2016-10-01

    Transcatheter aortic valve implantation (TAVI) has shown favorable outcomes in patients with severe symptomatic aortic valve stenosis who are at high surgical risk or inappropriate for open heart surgery. However, concerns exist over treating patients who have porcelain aorta and familial hypercholesterolemia, due to the potential complications of aortic root and aortic annulus. In this case report, we present a patient with familial hypercholesterolemia, symptomatic severe aortic stenosis, previous coronary artery bypass grafting and porcelain aorta, who was successfully treated with TAVI using a CoreValve. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Rehabilitation of the dominance of maxillary central incisors with refractory porcelain veneers requiring minimal tooth preparation.

    PubMed

    da Cunha, Leonardo Fernandes; Gonzaga, Carla Castiglia; Saab, Rafaella; Mushashe, Amanda Mahammad; Correr, Gisele Maria

    2015-01-01

    Central dominance is an important element of an esthetic smile. Color, form, and size have been suggested as tools for assessing the dominance of maxillary teeth. A spectrophotometer can be used to determine the value, hue, and chroma. Correct sizing of restorations according to the central incisor dominance principle improves not only esthetics but also aspects of occlusion, such as anterior guidance. Refractory porcelain systems can effectively restore the color, shape, emergence profile, and incisal translucency. This report illustrates the esthetic and occlusal rehabilitation of the dominance of maxillary central incisors using fabricated minimal thickness refractory porcelain veneers.

  15. Retrospective analysis of porcelain failures of metal ceramic crowns and fixed partial dentures supported by 729 implants in 152 patients: patient-specific and implant-specific predictors of ceramic failure.

    PubMed

    Kinsel, Richard P; Lin, Dongming

    2009-06-01

    Porcelain fracture associated with an implant-supported, metal ceramic crown or fixed partial denture occurs at a higher rate than in tooth-supported restorations, according to the literature. Implant-specific and patient-specific causes of ceramic failure have not been fully evaluated. The purpose of this retrospective study was to evaluate the potential statistical predictors for porcelain fracture of implant-supported, metal ceramic restorations. Over a 6-month period, a consecutive series of patients having previously received implant-supported, metal ceramic fixed restorations were examined during periodic recall appointments. The number of supporting implants, number of dental units, type of restoration, date of prosthesis insertion, location in the dental arch, opposing dentition, type of occlusion, presence of parafunctional habits, use of an occlusal protective device, presence or absence of ceramic fractures, gender, and age were recorded for each patient. The generalized estimating equation (GEE) approach was used for the intrasubject correlated measurements analysis of categorical outcomes (presence or absence of ceramic fractures) to determine which patient- and implant-specific factors would predict porcelain fracture (alpha=.05). Data were collected from 152 patients representing 998 dental units (390 single crowns and 94 fixed partial dentures) supported by 729 implants. Porcelain fractures of 94 dental units occurred in 35 patients. The fractures were significantly (P<.05) associated with opposing implant-supported metal ceramic restorations, bruxism, and not wearing a protective occlusal device. Metal ceramic prostheses (single crown or fixed partial dentures) had approximately 7 times higher odds of porcelain fracture (odds ratio (OR)=7.06; 95% confidence interval (CI): 2.57 to 19.37) and 13 times greater odds of a fracture requiring either repair or replacement (OR=13.95; 95% CI: 2.25 to 86.41) when in occlusion with another implant-supported restoration, as compared to opposing a natural tooth. In addition, patients exhibiting bruxism or not wearing an occlusal device had approximately 7 times higher odds (OR=7.23; 95% CI: 3.86 to 13.54), and 2 times higher odds (OR=1.92; 95% CI: 1.01 to 3.67) of porcelain fracture when compared to patients without bruxism and patients not wearing an occlusal device. Implant-supported metal ceramic single crowns and fixed partial dentures were found to have a significantly higher risk of porcelain fracture in patients with bruxism habits, when a protective occlusal device was not used, and when the restoration opposed another implant-supported metal ceramic restoration.

  16. In vitro rapid intraoral adjustment of porcelain prostheses using a high-speed dental handpiece.

    PubMed

    Song, Xiao-Fei; Yin, Ling; Han, Yi-Gang; Wang, Hui

    2008-03-01

    In vitro rapid intraoral adjustment of porcelain prostheses was conducted using a high-speed dental handpiece and diamond bur. The adjustment process was characterized by measurement of removal forces and energy, with scanning electron microscopic (SEM) observation of porcelain debris, surfaces and subsurface damage produced as a function of operational feed rate. Finite element analysis (FEA) was applied to evaluate subsurface stress distributions and degrees of subsurface damage. The results show that an increase in feed rate resulted in increases in both tangential and normal forces (analysis of variance (ANOVA), P<0.01). When the feed rate approached the highest rate of 60mm min(-1) at a fixed depth of cut of 100microm, the tangential force was nearly seven times that at the lowest feed rate of 15mm min(-1). Consequently, the specific removal energy increased significantly (ANOVA, P<0.01), and the maximum depth of subsurface damage obtained was approximately 110 and 120microm at the highest feed rate of 60mm min(-1) using SEM and FEA, respectively. The topographies of both the adjusted porcelain surfaces and the debris demonstrate microscopically that porcelain was removed via brittle fracture and plastic deformation. Clinicians must be cautious when pursuing rapid dental adjustments, because high operational energy, larger forces and severe surface and subsurface damage can be induced.

  17. [Effects of magnetron sputtered ZrN on the bonding strength of titanium porcelain].

    PubMed

    Zhou, Shu; Zhang, Wen-yan; Guang, Han-bing; Xia, Yang; Zhang, Fei-min

    2009-04-01

    To investigate the effect of magnetron sputtered ZrN on the bonding strength between a low-fusing porcelain (Ti/Vita titankeramik system) and commercially pure cast titanium. Sixteen specimens were randomly assigned to test group and control group (n=8). The control group received no surface treated. Magnetron sputtered ZrN film was deposited on the surface of specimens in the test group. Then the sixteen titanium-porcelain specimens were prepared in a rectangular shape and went through three-point bending test on a universal test machine. The bond strength of Ti/porcelain was recorded. The phase composition of the specimens was analyzed using X-ray diffraction (XRD). The interface at titanium and porcelain and the titanium surface after debonding were observed with a scanning electron microscopy (SEM) and analyzed using energy depressive spectrum (EDS). New phase of ZrN was found with XRD in the test group. Statistical analysis showed higher bond strength following ZrN surface treatment in the test group [(45.991+/-0.648) MPa] than that in the control group [(29.483+/-1.007) MPa] (P=0.000). Bonded ceramic could be observed in test group, the amount of bonded ceramic was more than that in the control group. No obvious bonded ceramic in control group was found. Magnetron sputtered ZrN can improve bond strength of Ti/Vita titankeramik system significantly.

  18. In vitro evaluation of the fracture resistance and microleakage of porcelain laminate veneers bonded to teeth with composite fillings after cyclic loading

    PubMed Central

    Sadighpour, Leyla; Fallahi Sichani, Babak; Kharazi Fard, Mohamd Javad

    2014-01-01

    PURPOSE There is insufficient data regarding the durability of porcelain laminate veneers bonded to existing composite fillings. The aim of the present study was to evaluate the fracture resistance and microleakage of porcelain laminate veneers bonded to teeth with existing composite fillings. MATERIALS AND METHODS Thirty maxillary central incisors were divided into three groups (for each group, n=10): intact teeth (NP), teeth with class III composite fillings (C3) and teeth with class IV cavities (C4). Porcelain laminate veneers were made using IPS-Empress ceramic and bonded with Panavia F2 resin cement. The microleakage of all of the specimens was tested before and after cyclic loading (1 × 106 cycles, 1.2 Hz). The fracture resistance values (N) were measured using a universal testing machine, and the mode of failure was also examined. The statistical analyses were performed using one-way ANOVA and Tukey post hoc tests (α=.05). RESULTS There was a significant difference in the mean microleakage of group C4 compared with group NT (P=.013). There was no significant difference in the fracture loads among the groups. CONCLUSION The microleakage and failure loads of porcelain laminate veneers bonded to intact teeth and teeth with standard class III composite fillings were not significantly different. PMID:25177471

  19. Implant-supported fixed dental prostheses with CAD/CAM-fabricated porcelain crown and zirconia-based framework.

    PubMed

    Takaba, Masayuki; Tanaka, Shinpei; Ishiura, Yuichi; Baba, Kazuyoshi

    2013-07-01

    Recently, fixed dental prostheses (FDPs) with a hybrid structure of CAD/CAM porcelain crowns adhered to a CAD/CAM zirconia framework (PAZ) have been developed. The aim of this report was to describe the clinical application of a newly developed implant-supported FDP fabrication system, which uses PAZ, and to evaluate the outcome after a maximum application period of 36 months. Implants were placed in three patients with edentulous areas in either the maxilla or mandible. After the implant fixtures had successfully integrated with bone, gold-platinum alloy or zirconia custom abutments were first fabricated. Zirconia framework wax-up was performed on the custom abutments, and the CAD/CAM zirconia framework was prepared using the CAD/CAM system. Next, wax-up was performed on working models for porcelain crown fabrication, and CAD/CAM porcelain crowns were fabricated. The CAD/CAM zirconia frameworks and CAD/CAM porcelain crowns were bonded using adhesive resin cement, and the PAZ was cemented. Cementation of the implant superstructure improved the esthetics and masticatory efficiency in all patients. No undesirable outcomes, such as superstructure chipping, stomatognathic dysfunction, or periimplant bone resorption, were observed in any of the patients. PAZ may be a potential solution for ceramic-related clinical problems such as chipping and fracture and associated complicated repair procedures in implant-supported FDPs. © 2012 by the American College of Prosthodontists.

  20. 46 CFR 111.01-13 - Limitations on porcelain use.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Limitations on porcelain use. 111.01-13 Section 111.01-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC... for lamp sockets, switches, receptacles, fuse blocks, or other electric equipment where the item is...

  1. 46 CFR 111.01-13 - Limitations on porcelain use.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Limitations on porcelain use. 111.01-13 Section 111.01-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC... for lamp sockets, switches, receptacles, fuse blocks, or other electric equipment where the item is...

  2. 46 CFR 111.01-13 - Limitations on porcelain use.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Limitations on porcelain use. 111.01-13 Section 111.01-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC... for lamp sockets, switches, receptacles, fuse blocks, or other electric equipment where the item is...

  3. 46 CFR 111.01-13 - Limitations on porcelain use.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Limitations on porcelain use. 111.01-13 Section 111.01-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC... for lamp sockets, switches, receptacles, fuse blocks, or other electric equipment where the item is...

  4. [Analysis of the unsuccessful cases of the porcelain-fused-to-metal-crowns and bridges].

    PubMed

    Zhai, Li-Yun; Zhao, Yu-Zhen; Wang, Shao-Ping; Yang, Yue-Hua

    2005-06-01

    To discuss the unsuccessful reasons and the preventive methods of the unsuccessful clinic cases. The retrospective analysis was carried on the 80 prosthesis in 70 patients from 1994 to 2001 which were suffered with unsuccessful results after the restoration of the metal crowns and bridges. There were 68 teeth which had collapsed or broken. 20 teeth had the post loosing or shedding. Root breaking, food impaction, unharmony colors of porcelain and the changing color of gingival were 3, 3, 6 and 2 teeth. It is necessary to select suitable repairing materials and operate correctly for preventing the occurring of the unsuccessful results in the porcelain-fused-to-metal-crowns and bridges.

  5. Gingival-colored Porcelain: A Clinical Report of an Esthetic-prosthetic Paradigm

    PubMed Central

    Sonune, Shital Jalandar; Kumar, Shiv; Jadhav, Manish Shivaji; Martande, Santosh

    2017-01-01

    Traditionally, periodontics has been instrumental in treating hard- and soft-tissue defect. Surgical and regenerative periodontal procedures can reconstruct the three-dimensional architecture of the hard- and soft-tissue defect. However, at times, these invasive procedures leave the patients with an esthetic problem. In such situations, the defects can be treated by the prosthetic approach. A predictable esthetically pleasing and functional outcome without any surgical procedure is being a choice of treatment for many. This article discusses about the treatment for the defect of excessive hard and soft tissue, using porcelain fused to a metal restoration with gingival-colored porcelain for both tooth-supported and implant-supported fixed prosthesis. PMID:29308371

  6. The non-destructive identification of early Chinese porcelain by PIXE

    NASA Astrophysics Data System (ADS)

    Cheng, H. S.; Zhang, Z. Q.; Zhang, B.; Yang, F. J.

    2004-06-01

    PIXE is used for the non-destructive differentiation of early precious Chinese blue and white porcelain made in Yuan (AD 1206-1368), Ming (AD 1368-1644) Dynasty in Jingdezhen from imitations. Also, ancient celadon made in Song Dynasty (AD 960-1279) is identified by measuring the trace elements contained in the glazes.

  7. 49 CFR 178.523 - Standards for composite packagings with inner glass, porcelain, or stoneware receptacles.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Standards for composite packagings with inner... Packaging Standards § 178.523 Standards for composite packagings with inner glass, porcelain, or stoneware receptacles. (a) The following are identification codes for composite packagings with inner receptacles of...

  8. 75 FR 74682 - Antidumping or Countervailing Duty Order, Finding, or Suspended Investigation; Opportunity To...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-01

    ...-605... 12/1/09-11/30/10 Porcelain-On-Steel Cooking Ware A-583-508........ 12/1/09-11/30/10 Welded Astm... Fittings A-570-881...... 12/1/09-11/30/10 Porcelain-on-Steel Cooking Ware A-570-506........ 12/1/09-11/30...

  9. 76 FR 12369 - Porcelain-on-Steel Cooking Ware From China

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-07

    ... Cooking Ware From China Determination On the basis of the record \\1\\ developed in the subject five-year... porcelain-on-steel cooking ware from China would be likely to lead to continuation or recurrence of material... Cooking Ware from China: Investigation No. 731-TA- 298 (Third Review). Issued: February 28, 2011. By order...

  10. Influence of the Conditioning Method for Pre-Sintered Zirconia on the Shear Bond Strength of Bilayered Porcelain/Zirconia

    PubMed Central

    Spintzyk, Sebastian; Yamaguchi, Kikue; Sawada, Tomofumi; Schille, Christine; Schweizer, Ernst; Ozeki, Masahiko; Geis-Gerstorfer, Jürgen

    2016-01-01

    This study evaluated the bond strength of veneering porcelain with an experimental conditioner-coated zirconia. Pre-sintered Y-TZP specimens (n = 44) were divided in two groups based on conditioning type. After sintering, all sample surfaces were sandblasted and layered with veneering porcelain. Additionally, half of the specimens in each group underwent thermal cycling (10,000 cycles, 5–55 °C), and all shear bond strengths were measured. After testing, the failure mode of each fractured specimen was determined. Differences were tested by parametric and Fisher’s exact tests (α = 0.05). The differences in bond strength were not statistically significant. Adhesive fractures were dominantly observed for the non-thermal cycled specimens. After thermal cycling, the conditioner-coated group showed cohesive and mixed fractures (p = 0.0021), whereas the uncoated group showed more adhesive fractures (p = 0.0021). Conditioning of the pre-sintered Y-TZP did not change the shear bond strength of the veneering porcelain, but did improve the failure mode after thermal cycling. PMID:28773885

  11. [Compatibility between high-strength dental ceramic (type A) and vintage AL veneering porcelain].

    PubMed

    Cui, Jun; Chao, Yong-lie; Meng, Yu-kun

    2006-05-01

    To investigate the interface bond strength and compatibility between High-Strength Dental Ceramic (type A) and Vintage AL veneering porcelain. Twenty bar-shape specimens (ten Vintage AL and ten Vitadur alpha) were fabricated, and shear test was conducted to determine the bond strength. A bilayered composite (1 mm core ceramic and 0.8 mm Vintage AL) was prepared and then fractured for scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) analysis. Ten all-ceramic anterior crowns were fabricated and the temperatures of thermal shock resistance were tested. The mean values of the bond strength measured were (55.52 +/- 14.64) MPa and (59.37 +/- 13.93) MPa for Vintage AL and Vitadur alpha respectively (P>0.05). SEM showed tight connection between the High-Strength Dental Ceramic (type A) and the veneering porcelain. Element diffusion was also confirmed by energy dispersive spectroscopy (EDS) analysis. The temperature of thermal shock resistance of this system was (179 +/- 15) degrees C. Vintage AL veneering porcelain has good thermal and chemical compatibility with High-Strength Dental Ceramic (type A).

  12. [A comparative study of marginal microleakage using different cements in porcelain-fused-to-metal crown].

    PubMed

    Jiang, Ming-Xin; Huang, Ke-Qiang; Li, Zhi-Gang; Gao, Xiu-Qiu; Li, Chun-Shan

    2011-04-01

    To evaluate the marginal microleakage of porcelain-fused-to-metal crown using four different cements. Sixteen porcelain-fused-to-metal crowns were built and randomly divided into 4 group, luted onto standard prepared human forward molars using four different cements (glass ionomer cement, resin-modified glass ionomer cement, PanaviaF, Super-Bond C&B adhesive luting system). After temperature cycling test, all the crowns were then submerged in 2% fuchsin for 24 h. The marginal microleakage at tooth cement interfaces was observed using light stereomicroscopy and evaluated in classification index. The marginal microleakage grade of 4 groups were analyzed by SPSS 13.0. The PanaviaF demonstrated the least marginal microleakage, Super-Bond C&B adhesive luting system, resin-modified glass ionomer cement showed an intermediate level of marginal microleakage, glass ionomer cement was associated with severe marginal microleakage (total, Chi2 = 157.60, P < 0.01; among the different groups, P<0.05). Adhesive resin luting system which is the first selection in clinical is better than glass ionomer cement and is good at porcelain-fused-to-metal crown.

  13. [Cr-Ti-Al-N complex coating on titanium to strengthen Ti/porcelain bonding].

    PubMed

    Zhang, Hui; Guo, Tian-wen; Li, Jun-ming; Pan, Jing-guang; Dang, Yong-gang; Tong, Yu

    2006-02-01

    To study the feasibility of magnetron sputtering Cr-Ti-Al-N complex coating as an interlayer on titanium to enhance the titanium-ceramic binding strength. With a three-point bending test according to ISO 9693, the binding strength of Duceratin (Degussa) to titanium substrate prepared with 4 different surface treatments (polishing, polishing and megnetron sputtering Cr, Ti, Al, and N complex coating, sandblasting, sandblasting and coating) was evaluated. Ti/porcelain interface and fractured Ti surface were examined using scanning electron microscopy with energy-dispersive spectrometry (EDS). The binding strength of polished and coated titanium/Duceratin was significantly higher than polished titanium group (P<0.05). The binding strength of sandblasted and coated titanium/Duceratin did not differ significantly from that of sandblasted titanium group (P>0.05), and the strength in the two sandblasted titanium groups was significantly higher than that in polished and coated titanium group (P<0.05). Megnetron sputtering Cr-Ti-Al-N complex on polished titanium can increase the titanium/porcelain binding strength. Megnetron sputtering coating is a promising Ti/porcelain interlayer.

  14. New insights into the role of Mn and Fe in coloring origin of blue decorations of blue-and-white porcelains by XANES spectroscopy

    NASA Astrophysics Data System (ADS)

    Zhu, Jian; Luo, Wugan; Chen, Dongliang; Xu, Wei; Ming, Chaofang; Wang, Changsui; Wang, Lihua

    2013-04-01

    Blue and white porcelain is one of the most valuable ancient ceramics varieties in ancient China. It is well known for its beautiful blue decorations. However, the origin of its blue color has not been very clear till now. In this research, two blue and white porcelains from Jingdezhen, Jiangxi province were selected and Mn and Fe K-edge XANES spectra were recorded from blue decorations with or without transparent glaze. Results showed that Mn K-edge XANES features were almost identical between different samples while that of iron changed. The above findings indicated the positive role of iron in the variation of blue decorations. As for manganese, although more system researches were need, its negative role on the variations of the tone of blue decorations was obtained. On the other hand, the paper also revealed the XAFS results will be affect by the glaze layer above the pigment. These findings provided us more information to understand the coloring origin of blue decorations of blue-and-white porcelain by means of XANES spectroscopy.

  15. Influence of peak oral temperatures on veneer–core interface stress state

    PubMed Central

    Marrelli, Massimo; Pujia, Antonella; Apicella, Davide; Sansalone, Salvatore; Tatullo, Marco

    2015-01-01

    Abstract Objective: There is a growing interest for the use of Y-TZP zirconia as core material in veneered all-ceramic prostheses. The objective of this study was to evaluate the influence of CET on the stress distribution of a porcelain layered to zirconia core single crowns by finite elements analysis. Material and methods: CET of eight different porcelains was considered during the analysis. Results: Results of this study indicated that the mismatch in CET between the veneering porcelain and the Y-TZP zirconia core has to be minimum (0.5–1 μm/mK) so as to decrease the growing of residual stresses which could bring chipping. Conclusions: The stress state due to temperature variation should be carefully taken into consideration while studying the effect of mechanical load on zirconia core crown by FEA. The interfacial stress state can be increased by temperature variation up to 20% with respect to the relative failure parameter (interface strength in this case). This means that stress due to mechanical load combined to temperature variation-induced stress can lead porcelain veneer–zirconia core interfaces to failure. PMID:28642897

  16. Joining Dental Ceramic Layers With Glass

    PubMed Central

    Saied, MA; Lloyd, IK; Haller, WK; Lawn, BR

    2011-01-01

    Objective Test the hypothesis that glass-bonding of free-form veneer and core ceramic layers can produce robust interfaces, chemically durable and aesthetic in appearance and, above all, resistant to delamination. Methods Layers of independently produced porcelains (NobelRondo™ Press porcelain, Nobel BioCare AB and Sagkura Interaction porcelain, Elephant Dental) and matching alumina or zirconia core ceramics (Procera alumina, Nobel BioCare AB, BioZyram yttria stabilized tetragonal zirconia polycrystal, Cyrtina Dental) were joined with designed glasses, tailored to match thermal expansion coefficients of the components and free of toxic elements. Scanning electron microprobe analysis was used to characterize the chemistry of the joined interfaces, specifically to confirm interdiffusion of ions. Vickers indentations were used to drive controlled corner cracks into the glass interlayers to evaluate the toughness of the interfaces. Results The glass-bonded interfaces were found to have robust integrity relative to interfaces fused without glass, or those fused with a resin-based adhesive. Significance The structural integrity of the interfaces between porcelain veneers and alumina or zirconia cores is a critical factor in the longevity of all-ceramic dental crowns and fixed dental prostheses. PMID:21802131

  17. [Preliminary evaluation on self-developed dentin porcelain color prediction system].

    PubMed

    Chen, L; Lu, C; Li, X L; Zhu, X M; Zhang, S; Tan, J G

    2016-09-01

    To apply the self-developed dentin porcelain color prediction system in the fabrication of porcelain-fused-to-metal-crown(PFMC), and to evaluate its accuracy in color-matching. Twenty upper central incisors were recruited according to preset criteria, and three PFMC were made for each tooth using three shade-matching techniques. Group A: PFMC were made according to the result of visual color selection; Group B: an spectrophotometer-based color-matching technique was used; Group C: PFMC were fabricated with dentin porcelain powder calculated by the prediction system according to the L(*), a(*), b(*) value measured by a spectrophotometer. Color differences(ΔE) (measured by spectrophotometer) of three groups of crowns were calculated in the cervical, middle, and incisal regions. The results were analyzed using one-way ANOVA. Mean color differences in body regions were: Group A: 3.53±1.80, Group B: 2.86±1.63, Group C: 3.77±1.40(P>0.05), and those in incisal regions were: Group A: 2.70 ± 1.13, Group B: 2.80 ± 0.90, Group C: 3.04 ± 1.03(P>0.05). In cervical region, Group C had greater color difference than Group B(2.78±1.14)(P<0.05). Group A(3.80±2.02) and Group B, Group A and Group C had similar color difference(P>0.05). PFMC fabricated using self-developed dentin porcelain color prediction system had similar color matching compared with conventional and instrument-based methods.

  18. Strain gauge analysis of the effect of porcelain firing simulation on the prosthetic misfit of implant-supported frameworks.

    PubMed

    De Vasconcellos, Diego Klee; Özcan, Mutlu; Maziero Volpato, Cláudia Ângela; Bottino, Marco Antonio; Yener, Esra Salihoğlu

    2012-06-01

    This study investigated the effect of porcelain firing on the misfit of implant-supported frameworks and analyzed the influence of preheat treatment on the dimensional alterations. Four external-hex cylindrical implants were placed in polyurethane block. Ten frameworks of screw-retained implant-supported prostheses were cast in Pd-Ag using 2 procedures: (1) control group (CG, n = 5): cast in segments and laser welded; and test group (TG, n = 5): cast in segments, preheated, and laser welded. All samples were subjected to firing to simulate porcelain veneering firing. Strain gauges were bonded around the implants, and microstrain values (με = 10⁻⁶ε) were recorded after welding (M1), oxidation cycle (M2), and glaze firing (M3). Data were statistically analyzed (2-way analysis of variance, Bonferroni, α = 0.05). The microstrain value in the CG at M3 (475.2 με) was significantly different from the values observed at M1 (355.6 με) and M2 (413.9 με). The values at M2 and M3 in the CG were not statistically different. Microstrain values recorded at different moments (M1: 361.6 με/M2: 335.3 με/M3: 307.2 με) did not show significant difference. The framework misfit deteriorates during firing cycles of porcelain veneering. Metal distortion after porcelain veneering could be controlled by preheat treatment.

  19. Percutaneous implantation of the CoreValve® self-expanding valve prosthesis in patients with severe aortic stenosis and porcelain aorta: medium-term follow-up.

    PubMed

    Pascual, Isaac; Avanzas, Pablo; Muñoz-García, Antonio J; López-Otero, Diego; Jimenez-Navarro, Manuel F; Cid-Alvarez, Belén; del Valle, Raquel; Alonso-Briales, Juan H; Ocaranza-Sanchez, Raimundo; Alfonso, Fernando; Hernández, José M; Trillo-Nouche, Ramiro; Morís, César

    2013-10-01

    There is little information on the use of transcatheter aortic valve implantation in patients with severe aortic stenosis and porcelain aorta. The primary aim of this study was to analyze death from any cause after CoreValve(®) implantation in patients with severe aortic stenosis, with and without porcelain aorta. In this multicenter, observational prospective study, carried out in 3 hospitals, percutaneous aortic valves were implanted in 449 patients with severely calcified aortic stenosis. Of these, 36 (8%) met the criteria for porcelain aorta. The primary end-point was death from any cause at 2 years. Patients with porcelain aorta more frequently had extracardiac vascular disease (11 [30.6%] vs 49 [11.9%]; P=.002), prior coronary revascularization (15 [41.7%] vs 98 [23.7%]; P=.017), and dyslipidemia (26 [72.2%] vs 186 [45%]; P=.02). In these patients, there was greater use of general anesthesia (15 [41.7%] vs 111 [16.9%]; P=.058) and axillary access (9 [25%] vs 34 [8.2%]; P=.004). The success rate of the procedure (94.4 vs 97.3%; P=.28) and the incidence of complications (7 [19.4%] vs 48 [11.6%]; P=.20) were similar in both groups. There were no statistically significant differences in the primary end point at 24 months of follow-up (8 [22.2%] vs 66 [16%]; P=.33). The only predictive variable for the primary end point was the presence of complications during implantation (hazard ratio=2.6; 95% confidence interval, 1.5-4.5; P=.001). In patients with aortic stenosis and porcelain aorta unsuitable for surgery, percutaneous implantation of the CoreValve(®) self-expanding valve prosthesis is safe and feasible. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  20. Influence of coping design on the cervical color of ceramic crowns.

    PubMed

    Paniz, Gianluca; Kang, Ki-Ho; Kim, Yongjeong; Kumagai, Naota; Hirayama, Hiroshi

    2013-12-01

    The replication of natural teeth, especially with single-tooth restorations, represents a challenge. Similar to metal ceramic crowns, different designs of zirconia substructures have been suggested to improve the esthetic results of zirconia ceramic crowns. The purpose of the study was to analyze the color of the cervical portion of single zirconia ceramic crowns fabricated with different zirconia coping designs. The color, measured on the CIELAB color scale, of 3 different groups of restorations (n=10) fabricated with zirconia coping (Lava) and feldspathic porcelain (Noritake Super Porcelain) was analyzed with a spectrophotometer. Conventional zirconia crowns with zirconia facial margins were compared with ceramic crowns with porcelain facial margins and either a horizontal reduction of the zirconia coping (1.0 mm reduction) or an additional vertical reduction (1.0 mm additional reduction). The 3 groups, each with a different coping extension, were examined with a 1-way ANOVA and the Fisher exact test, and the differences of the groups were evaluated by applying ΔE thresholds (α=.05). The mean color difference among all the groups was not clinically significant (ΔE<3.7). Reduced color differences were present between the 2 porcelain butt margin groups of crowns (ΔE=1.06, between group H and V). Increased differences were present between the zirconia margin group and the porcelain butt margin group (ΔE=2.54 between group C and H; ΔE=2.41 between group C and V). Lab* values were examined in all the groups of crowns to determine the clinical implications. Within the limitation of the study, no significant differences were present among the tested groups of crowns. Nevertheless, although some differences were present between the zirconia margin group and the porcelain butt margin group, reduced differences were present between the 2 different cutback designs. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  1. [Influence of different designs and porcelain/glaze firing on the marginal and internal fit of implant-supported zirconia crowns].

    PubMed

    Cuiling, Liu; Xu, Gao; Yuping, Qi; Liyuan, Yang

    2016-02-01

    This study investigated the influence of different designs and porcelain/glaze firing on the marginal and internal fit of three kinds of computer aided design/computer aided manufacturing (CAD/CAM) zirconia ceramic implant-supported crowns. Three groups of zirconia ceramic implant-supported crowns with different designs were produced from copings by using a Cercon CAD/CAM system (n = 8). The first two groups comprised double-layer crowns (zirconia coping + veneer) with regular (Group A) and full circumferential zirconia-collar marginal designs (Group B). The third group was composed of anatomic single-layer zirconia crowns without cores (Group C). Initially, the marginal and internal gaps of the copings and crowns were individually replicated by light-body silicon and then measured by micro-computed tomography scanning before and after porcelain/glaze firing. Five measurements were employed: vertical marginal gap (MG); horizontal marginal discrepancy (HMD); chamfer area (CA); axial wall (AW); and axial-occlusal transition area (AOT). Statistical analyses were performed by SPSS 17.0. HMD measurements in Group A were statistically higher than those in Groups B and C (P < 0.05), regardless of whether the values were obtained before or after porcelain/glaze firing. By contrast, the HIMD measurements in Groups B and C showed no significant difference (P > 0.05). Moreover, no differences were noted in MG, CA, AW, and AOT among the three groups (P > 0.05). All the measurements in the three groups showed no significant change after porcelain/glaze firing (P > 0.05), except for MG in Group A, which significantly decreased (P < 0.05). The marginal fits of the double-layer crowns with full circumferential zirconia-collar and the anatomic single-layer zirconia crowns were superior to that of the double-layer crowns with regular margins. The MG of the crowns with regular margins was obviously influenced by porcelain firing.

  2. Evolutionary morphology of the organ systems in squat lobsters and porcelain crabs (crustacea: Decapoda: Anomala): an insight into carcinization.

    PubMed

    Keiler, Jonas; Richter, Stefan; Wirkner, Christian S

    2015-01-01

    Porcelain crabs (Porcellanidae) are one of three taxa within anomuran crustaceans (Anomala) which possess a crab-like body form. Curiously, these three lineages evolved this shape independently from true crabs (Brachyura) in the course of the evolutionary process termed carcinization. The entire pleon in porcelain crabs is flexed under the cephalothorax and the carapace is approximately as broad as long. Despite their crab-like habitus, porcelain crabs are phylogenetically nested within squat lobsters (Munidopsidae, Munididae, Galatheidae). With a pleon which is only partly flexed under the cephalothorax and a cephalothorax which is longer than it is broad, squat lobsters represent morphologically intermediate forms between lobster-like and crab-like body shapes. Carcinization has so far mostly been studied with respect to outer morphology; however, it is evident that internal anatomical features are influenced through this change of body shape too. In this paper, the situation in Galatheoidea is elucidated by adding more taxa to existing descriptions of the hemolymph vascular systems and associated structures and organs. Micro-computer tomography and 3D reconstruction provide new insights. Autapomorphic states of various internal anatomical characters are present in nearly all the studied species, also reflecting some degree of anatomical disparity found within Galatheoidea. The ventral vessel system of porcelain crabs differs distinctly from that of squat lobsters. The differences in question are coherent (i.e. structural dependent) with morphological transformations in the integument, such as the shortening of the sternal plastron, which evolved in the course of carcinization. Shifts in the gonads and the pleonal neuromeres are coherent with the loss of the caridoid escape reaction, which in turn is a consequence of carcinization. The arterial transformations, however, are minor compared to other instances of carcinization in anomuran crustaceans since the last common ancestor of squat lobsters and porcelain crabs was already "half carcinized". © 2014 Wiley Periodicals, Inc.

  3. The effect of enamel porcelain thickness on color and the ability of a shade guide to prescribe chroma.

    PubMed

    Jarad, F D; Moss, B W; Youngson, C C; Russell, M D

    2007-04-01

    To test the null hypothesis that there is no color change when enamel porcelain thickness is changed and to evaluate the ability of a shade guide to prescribe chroma. Three shades (3M1, 3M2 and 3M3) were selected from a Vitapan 3D master shade guide. Five disk specimens were prepared for each shade, consisting of three layers (opacious dentin, dentin and enamel) at thicknesses of 0.6, 0.8 and 0.6mm, respectively. The color of each disk was measured using a spectrophotometer. Enamel porcelain was reduced in thickness to 0.3mm and porcelain disks were remeasured. Reducing the enamel thickness of porcelain disk specimens significantly increased L) (p<0.05), b*, metric chroma and hue angle (p<0.001). For the three shades studied (3M1, 3M2 and 3M3) L* values were not significantly different (p>0.05) and chroma increased for 3M1 with the lowest chroma to 3M3 with the highest chroma, which is in line with the shade guide specifications. Although statistically significant (p<0.001) changes in hue angle between the three shades were small (less than 3 degrees overall). The difference in chroma between the three shades 3M1, 3M2 and 3M3 was greatest for the thin enamel layer than the thick enamel layer. A change in enamel thickness from 0.6 to 0.3mm resulted in a three-unit change in L* and metric chroma and a 4 degrees change in hue angle. A change in enamel porcelain thickness will have a greater effect on higher chromatic shades than those with lower chroma. The ability of the shade guide to prescribe chroma was demonstrated but this could be offset by an anomalous enamel thickness.

  4. Effect of metal conditioner on bonding of porcelain to cobalt-chromium alloy

    PubMed Central

    Kajihara, Yutaro; Takenouchi, Yoshihisa; Tanaka, Takuo; Suzuki, Shiro; Minami, Hiroyuki

    2016-01-01

    PURPOSE The purpose of this study was to evaluate the efficacy of two different metal conditioners for non-precious metal alloys for the bonding of porcelain to a cobalt-chromium (Co-Cr) alloy. MATERIALS AND METHODS Disk-shaped specimens (2.5×10.0 mm) were cast with Co-Cr alloy and used as adherend materials. The bonding surfaces were polished with a 600-grid silicon carbide paper and airborne-particle abraded using 110 µm alumina particles. Bonding specimens were fabricated by applying and firing either of the metal conditioners on the airborne-particle abraded surface, followed by firing porcelain into 5 mm in diameter and 3 mm in height. Specimens without metal conditioner were also fabricated. Shear bond strength for each group (n=8) were measured and compared (α=.05). Sectional view of bonding interface was observed by SEM. EDS analysis was performed to determine the chemical elements of metal conditioners and to determine the failure modes after shear test. RESULTS There were significant differences among three groups, and two metal conditioner-applied groups showed significantly higher values compared to the non-metal conditioner group. The SEM observation of the sectional view at bonding interface revealed loose contact at porcelain-alloy surface for non-metal conditioner group, however, close contact at both alloy-metal conditioner and metal conditioner-porcelain interfaces for both metal conditioner-applied groups. All the specimens showed mixed failures. EDS analysis showed that one metal conditioner was Si-based material, and another was Ti-based material. Si-based metal conditioner showed higher bond strengths compared to the Ti-based metal conditioner, but exhibited more porous failure surface failure. CONCLUSION Based on the results of this study, it can be stated that the application of metal conditioner is recommended for the bonding of porcelain to cobalt-chromium alloys. PMID:26949481

  5. Effect of metal selection and porcelain firing on the marginal accuracy of titanium-based metal ceramic restorations.

    PubMed

    Shokry, Tamer E; Attia, Mazen; Mosleh, Ihab; Elhosary, Mohamed; Hamza, Tamer; Shen, Chiayi

    2010-01-01

    Titanium is the most biocompatible metal used for dental casting; however, there is concern about its marginal accuracy after porcelain application since this aspect has direct influence on marginal fit. The purpose of this study was to determine the effect that metal selection and the porcelain firing procedure have on the marginal accuracy of metal ceramic prostheses. Cast CP Ti, milled CP Ti, cast Ti-6Al-7Nb, and cast Ni-Cr copings (n=5) were fired with compatible porcelains (Triceram for titanium-based metals and VITA VMK 95 for Ni-Cr alloy). The Ni-Cr alloy fired with its porcelain served as the control. Photographs of metal copings placed on a master die were made. Marginal discrepancy was determined on the photographs using an image processing program at 8 predetermined locations before airborne-particle abrasion for porcelain application, after firing of the opaque layer, and after firing of the dentin layer. Repeated-measures 2-way ANOVA was used to investigate the effect of metal selection and firing stage, and paired t tests were used to determine the effect of each firing stage within each material group (alpha=.05). ANOVA showed that both metal selection and firing stage significantly influenced the measured marginal discrepancy (P<.001), and there was interaction between the 2 variables (P<.001). Student-Newman-Keuls multiple comparison tests showed that there were significant differences between any 2 metals compared, at each stage of measurement. Paired t tests showed that significant changes in marginal discrepancy occurred with opaque firing on milled CP Ti (P=.017) and cast Ti-6Al-7Nb alloy (P=.003). Titanium copings fabricated by CAD/CAM demonstrated the least marginal discrepancy among all groups, while the base metal (Ni-Cr) groups exhibited the most discrepancy of all groups tested. Copyright 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  6. Evaluation of the mechanical properties and porcelain bond strength of cobalt-chromium dental alloy fabricated by selective laser melting.

    PubMed

    Wu, Lin; Zhu, Haiting; Gai, Xiuying; Wang, Yanyan

    2014-01-01

    Limited information is available regarding the microstructure and mechanical properties of dental alloy fabricated by selective laser melting (SLM). The purpose of this study was to evaluate the mechanical properties of a cobalt-chromium (Co-Cr) dental alloy fabricated by SLM and to determine the correlation between its microstructure and mechanical properties and its porcelain bond strength. Five metal specimens and 10 metal ceramic specimens were fabricated to evaluate the mechanical properties of SLM Co-Cr dental alloy (SLM alloy) with a tensile test and its porcelain bond strength with a 3-point bending test. The relevant properties of the SLM alloy were compared with those of the currently used Co-Cr dental alloy fabricated with conventional cast technology (cast alloy). The Student t test was used to compare the results of the SLM alloy and the cast alloy (α=.05). The microstructure of the SLM alloy was analyzed with a metallographic microscope; the metal ceramic interface of the SLM porcelain bonded alloy was studied with scanning electron microscopy, energy dispersive x-ray spectroscopy, and an electron probe microanalyzer. Both the mean (standard deviation) yield strength (884.37 ± 8.96 MPa) and tensile strength (1307.50 ±10.65 MPa) of the SLM alloy were notably higher than yield strength (568.10 ± 30.94 MPa) and tensile strength (758.73 ± 25.85 MPa) of the currently used cast alloy, and the differences were significant (P<.05). The porcelain bond strength of the SLM alloy was 55.78 ± 3.02 MPa, which was similar to that of the cast alloy, 54.17 ± 4.96 MPa (P>.05). Microstructure analysis suggested that the SLM alloy had a dense and obviously orientated microstructure, which led to excellent mechanical properties. Analysis from scanning electron microscopy, energy dispersive x-ray spectroscopy, and the electron probe microanalyzer indicated that the SLM alloy had an intermediate layer with elemental interpenetration between the alloy and the porcelain, which resulted in an improved bonding interface. Compared with the currently used cast alloy, SLM alloy possessed improved mechanical properties and similar porcelain bond strength. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  7. [Effect of niobium nitride on the bonding strength of titanium porcelain by magnetron sputtering].

    PubMed

    Wang, Shu-shu; Zhang, La-bao; Guang, Han-bing; Zhou, Shu; Zhang, Fei-min

    2010-05-01

    To investigate the effect of magnetron sputtered niobium nitride (NbN) on the bonding strength of commercially pure cast titanium (Ti) and low-fusing porcelain (Ti/Vita titankeramik system). Sixty Ti specimens were randomly divided into four groups, group T1, T2, T3 and T4. All specimens of group T1 and T2 were first treated with 120 microm blasted Al2O3 particles, and then only specimens of group T2 were treated with magnetron sputtered NbN film. All specimens of group T3 and T4 were first treated with magnetron sputtered NbN film and then only specimens of group T4 were treated with 120 microm blasted Al2O3 particles. The composition of the deposits were analyzed by X-ray diffraction (XRD). A universal testing machine was used to perform the three-point bending test to evaluate the bonding strength of Ti and porcelain. The microstructure of NbN, the interface of Ti-porcelain and the fractured Ti surface were observed with scanning electron microscopy (SEM) and energy depressive spectrum (EDS), and the results were compared. The XRD results showed that the NbN deposits were cubic crystalline phases. The bonding strength of Ti and porcelain in T1 to T4 group were (27.2+/-0.8), (43.1+/-0.6), (31.4+/-1.0) and (44.9+/-0.6) MPa. These results were analyzed by one-way analysis of variance and differences between groups were compared using least significant difference test. Significant inter-group differences were found among all groups (P<0.05). The results of SEM showed that with treatment of Al2O3 or NbN, alone, pre-cracks were found in the interface of Ti-porcelain, while samples treated with both Al2O3 and NbN had better bond. EDS of Ti-porcelain interface showed oxidation occurred in T1, T2 and T3, but was well controlled in T4. Magnetron sputtered NbN can prevent Ti from being oxidized, and can improve the bonding strength of Ti/Vita titankeramik system. Al2O3 blast can also improve the bonding strength of Ti/Vita titankeramik system.

  8. Modification to the AOAC Sporicidal Activity of Disinfectants Test (Method 966.04): collaborative study.

    PubMed

    Tomasino, Stephen F; Hamilton, Martin A

    2006-01-01

    In an effort to improve AOAC Method 966.04, the Sporicidal Activity of Disinfectants Test, selected modifications to the procedure were evaluated in a collaborative study. Method 966.04 is used to generate efficacy data to support the product registration of sporicides and sterilants. The method is a carrier-based test that provides a qualitative measure of product efficacy against spores of Bacillus subtilis and Clostridium sporogenes. The use of garden soil extract and the lack of standard procedures for the enumeration of spores and neutralization of the test chemicals have been considered problematic for many years. The proposed modifications were limited to the B. subtilis and hard surface carrier (porcelain penicylinder) components of the method. The study included the evaluation of a replacement for soil extract nutrient broth and an establishment of a minimum spore titer per carrier, both considered crucial for the improvement and utilization of the method. Additionally, an alternative hard surface material and a neutralization confirmation procedure were evaluated. To determine the equivalence of the proposed alternatives to the standard method, 3 medium/carrier combinations, (1) soil extract nutrient broth/porcelain carrier (current method), (2) nutrient agar amended with 5 microg/mL manganese sulfate/porcelain carrier, and (3) nutrient agar amended with 5 microg/mL manganese sulfate/stainless steel carrier were analyzed for carrier counts, HCI resistance, efficacy, quantitative efficacy, and spore wash-off. The test chemicals used in the study represent 3 chemical classes and are commercially available antimicrobial liquid products: sodium hypochlorite (bleach), glutaraldehyde, and a combination of peracetic acid and hydrogen peroxide. Four laboratories participated in the study. The results of the spore titer per carrier, HCI resistance, efficacy, and wash-off studies demonstrate that amended nutrient agar in conjunction with the porcelain is comparable to the current method, soil extract nutrient broth/porcelain. The nutrient agar method is simple, inexpensive, reproducible, and provides an ample supply of high quality spores. Due to the current use of porcelain carriers for testing C. sporogenes, it is advisable to retain the use of porcelain carriers until stainless steel can be evaluated as a replacement carrier material for Clostridium. The evaluation of stainless steel for Clostridium has been initiated by the Study Director. Study Director recommendations for First Action revisions are provided in a modified method.

  9. Dual-scan technique for the customization of zirconia computer-aided design/computer-aided manufacturing frameworks.

    PubMed

    Andreiuolo, Rafael Ferrone; Sabrosa, Carlos Eduardo; Dias, Katia Regina H Cervantes

    2013-09-01

    The use of bi-layered all-ceramic crowns has continuously grown since the introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia cores. Unfortunately, despite the outstanding mechanical properties of zirconia, problems related to porcelain cracking or chipping remain. One of the reasons for this is that ceramic copings are usually milled to uniform thicknesses of 0.3-0.6 mm around the whole tooth preparation. This may not provide uniform thickness or appropriate support for the veneering porcelain. To prevent these problems, the dual-scan technique demonstrates an alternative that allows the restorative team to customize zirconia CAD/CAM frameworks with adequate porcelain thickness and support in a simple manner.

  10. Fracture strength of all-ceramic lithium disilicate and porcelain-fused-to-metal bridges for molar replacement after dynamic loading.

    PubMed

    Chitmongkolsuk, Somsak; Heydecke, Guido; Stappert, Christian; Strub, Joerg R

    2002-03-01

    The replacement of missing posterior teeth using all-ceramic bridges remains a challenge. This study compares the fracture resistance of all-ceramic 3-unit bridges for the replacement of first molars to conventional porcelain-fused-to-metal bridges. Human premolars and molars were used to create two test groups and one control group of 16 specimens each. To simulate clinical parameters, the specimens were exposed to cyclic fatigue loading in an artificial mouth with simultaneous thermocycling. All samples were thereafter exposed to fracture strength testing. Porcelain-fused-to-metal bridges showed significantly higher fracture strengths than all-ceramic bridges. However, the fracture strength of the all-ceramic bridges was higher than peak physiological chewing forces.

  11. Effects of metal surface grinding at the porcelain try-in stage of fixed dental prostheses.

    PubMed

    Kılınç, Halil İbrahim; Kesim, Bülent; Gümüş, Hasan Önder; Dinçel, Mehmet; Erkaya, Selçuk

    2014-08-01

    This study was to evaluate the effect of grinding of the inner metal surface during the porcelain try-in stage on metal-porcelain bonding considering the maximum temperature and the vibration of samples. Ninety-one square prism-shaped (1 × 1 × 1.5 mm) nickel-chrome cast frameworks 0.3 mm thick were prepared. Porcelain was applied on two opposite outer axial surfaces of the frameworks. The grinding was performed from the opposite axial sides of the inner metal surfaces with a low-speed handpiece with two types of burs (diamond, tungsten-carbide) under three grinding forces (3.5 N, 7 N, 14 N) and at two durations (5 seconds, 10 seconds). The shear bond strength (SBS) test was performed with universal testing machine. Statistical analyzes were performed at 5% significance level. The samples subjected to grinding under 3.5 N showed higher SBS values than those exposed to grinding under 7 N and 14 N (P<.05). SBS values of none of the groups differed from those of the control group (P>.05). The types of bur (P=.965) and the duration (P=.679) did not affect the SBS values. On the other hand, type of bur, force applied, and duration of the grinding affected the maximum temperatures of the samples, whereas the maximum vibration was affected only by the type of bur (P<.05). Grinding the inner metal surface did not affect the metal-porcelain bond strength. Although the grinding affected the maximum temperature and the vibration values of the samples, these did not influence the bonding strength.

  12. [Effect of sandblasting particle sizes on bonding strength between porcelain and titanium fabricated by rapid laser forming].

    PubMed

    Zhang, Li-jun; Wang, Zhong-yi; Gao, Bo; Gao, Yang; Zhang, Chun-bao

    2009-11-01

    To evaluate the effect of sandblasting particle sizes of Al2O3 on the bonding strength between porcelain and titanium fabricated by laser rapid forming (LRF). The thermal expansion coefficient, roughness (Ra), contact angle, surface morphology of titanium surface and the bonding strength between titanium and porcelain were evaluated after the titanium surface being sandblasted using different sizes of Al2O3 (50 microm, 120 microm, 250 microm) at a pressure of 0.5 MPa. The cast titanium specimens were used as control, and were sandblasted with 50 microm Al2O3 at the same pressure. The thermal expansion coefficient of cast titanium [(9.84 +/- 0.42) x 10(-6)/ degrees C] and LRF Ti [(9.79 +/- 0.31) x 10(-6)/ degrees C) matched that of Noritake Ti-22 dentin porcelain [(8.93 +/- 0.36) x 10(-6)/ degrees C). When larger size of Al2O3 was used, the value of Ra and contact angle increased as well. There was no significant difference in bonding strength between the LRF Ti-50 microm [(25.91 +/- 1.02) MPa] and cast titanium [(26.42 +/- 1.65) MPa]. Significantly lower bonding strength was found in LRF Ti-120 microm [(21.86 +/- 1.64) MPa] and LRF Ti-250 microm [(19.96 +/- 1.03) MPa]. The bond strength between LRF Ti and Noritake Ti-22 dentin porcelain was above the lower limit value in the ISO 9693 (25 MPa) after using 50 microm Al2O3 sandblasting in 0.5MPa air pressure.

  13. Color related to ceramic and zirconia restorations: a review.

    PubMed

    Vichi, Alessandro; Louca, Chris; Corciolani, Gabriele; Ferrari, Marco

    2011-01-01

    The requirement to achieve natural looking restorations is one of the most challenging aspects of dentistry, and the shade matching of dental restorations with the natural dentition is a difficult task due to the complex optical characteristics of natural teeth. Dental porcelain is considered the reference material for prosthetic rehabilitation, but it is not easy to handle and aesthetic excellence is quite difficult to obtain. For these reasons, shade matching with dental porcelain is often considered to be more artistic than scientific. Shade matching is considered unpredictable due to several variables that may influence the final appearance of a restoration. In order to improve this situation, over the last decade new shade guides and instruments have been developed and the aesthetic aspects of dental porcelain have been further investigated. In this review some aspects of color selection and color reproduction have been examined. Color selection has advanced through the development of new shade guides and electronic shade taking devices, although visual assessment has still not been entirely replaced by electronic instruments. Color reproduction with dental porcelain has improved thanks to advances in the performance and knowledge of dental porcelain, but is still not easy to achieve. The difficulties of achieving good aesthetics with PFM restorations and the desire for metal free solutions have resulted in the increased use of zirconia. The unique optical properties of zirconia have introduced new opportunities for achieving superior aesthetics, however further research is required with this material. Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. 32. TYPICAL BRYANT ITEMS FROM THE 1930S; TOP ROW LEFT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    32. TYPICAL BRYANT ITEMS FROM THE 1930S; TOP ROW LEFT TO RIGHT: PORCELAIN CASED SWITCH, ROTARY SWITCH, SHORTING PLUG TO BYPASS FUSE; SECOND ROW: BRASS INCANDESCENT LAMP SURFACE RECEPTACLE, INCANDESCENT LAMPHOLDER WITH ADAPTER FOR GLASS GLOBE; THIRD ROW: PORCELAIN BASE ROTARY SWITCH, APPLIANCE BREAKER WITH COVER REMOVED, APPLIANCE BREAKER - Bryant Electric Company, 1421 State Street, Bridgeport, Fairfield County, CT

  15. 76 FR 2708 - Porcelain-on-Steel Cooking Ware From Taiwan; Top-of-the-Stove Stainless Steel Cooking Ware From...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-14

    .... 701- TA-267 and 731-TA-304 (Third Review)] Porcelain-on-Steel Cooking Ware From Taiwan; Top-of-the-Stove Stainless Steel Cooking Ware From Korea AGENCY: United States International Trade Commission...-steel cooking ware from Taiwan and the antidumping and countervailing duty orders on imports of top-of...

  16. Wear characteristics of polished and glazed lithium disilicate ceramics opposed to three ceramic materials.

    PubMed

    Saiki, Osamu; Koizumi, Hiroyasu; Akazawa, Nobutaka; Kodaira, Akihisa; Okamura, Kentaro; Matsumura, Hideo

    2016-01-01

    This study compared the wear characteristics of a heat-pressed lithium disilicate ceramic material opposed to feldspathic porcelain, a lithium disilicate glass ceramic, and zirconia materials. Ceramic plate specimens were prepared from feldspathic porcelain (EX-3 nA1B), lithium disilicate glass ceramics (e.max CAD MO1/C14), and zirconia (Katana KT 10) and then ground or polished. Rounded rod specimens were fabricated from heat-pressed lithium disilicate glass ceramic (e.max press LT A3) and then glazed or polished. A sliding wear testing apparatus was used for wear testing. Wear of glazed rods was greater than that of polished rods when they were abraded with ground zirconia, ground porcelain, polished porcelain, or polished lithium disilicate ceramics. For both glazed and polished rods, wear was greater when the rods were abraded with ground plates. The findings indicate that application of a polished surface rather than a glazed surface is recommended for single restorations made of heat-pressed lithium disilicate material. In addition, care must be taken when polishing opposing materials, especially those used in occlusal contact areas. (J Oral Sci 58, 117-123, 2016).

  17. Retrospective study on the performance of porcelain laminate veneers delivered by undergraduate dental students.

    PubMed

    Murphy, E; Ziada, H M; Allen, P F

    2005-03-01

    The aim of this study was to retrospectively evaluate the clinical performance of porcelain laminate veneer restorations delivered by undergraduate students at the Department of Restorative Dentistry, University Dental School and Hospital Cork and to analyze the factors that influence their prognosis and their effect on periodontal health. Patients who had veneers fitted over a period of 5 yrs. were recalled for evaluation. The recall protocol took the form of a questionnaire and a full clinical examination of the teeth involved and contra lateral control teeth. In all, 29 patients with 62 porcelain veneers were examined, only 2 of which were in the mandible. 77% of patients had veneers fitted due to discolouration, 13% in order to alter the shape or size of teeth and 10% due to palatal erosion. On the date of recall 89% of veneers had never debonded or fractured, 6% had to be rebonded since the date of insertion and 5% presented with a fracture. From this study it appears that porcelain laminate veneers are successful in the treatment of discoloured and irregular configured anterior teeth. It shows that undergraduate students can deliver satisfactory veneer restorations.

  18. Resistance to abrasion of extrinsic porcelain esthetic characterization techniques.

    PubMed

    Chi, Woo J; Browning, William; Looney, Stephen; Mackert, J Rodway; Windhorn, Richard J; Rueggeberg, Frederick

    2017-01-01

    A novel esthetic porcelain characterization technique involves mixing an appropriate amount of ceramic colorants with clear, low-fusing porcelain (LFP), applying the mixture on the external surfaces, and firing the combined components onto the surface of restorations in a porcelain oven. This method may provide better esthetic qualities and toothbrush abrasion resistance compared to the conventional techniques of applying color-corrective porcelain colorants alone, or applying a clear glaze layer over the colorants. However, there is no scientific literature to support this claim. This research evaluated toothbrush abrasion resistance of a novel porcelain esthetic characterization technique by subjecting specimens to various durations of simulated toothbrush abrasion. The results were compared to those obtained using the conventional characterization techniques of colorant application only or colorant followed by placement of a clear over-glaze. Four experimental groups, all of which were a leucite reinforced ceramic of E TC1 (Vita A1) shade, were prepared and fired in a porcelain oven according to the manufacturer's instructions. Group S (stain only) was characterized by application of surface colorants to provide a definitive shade of Vita A3.5. Group GS (glaze over stain) was characterized by application of a layer of glaze over the existing colorant layer as used for Group S. Group SL (stain+LFP) was characterized by application of a mixture of colorants and clear low-fusing add-on porcelain to provide a definitive shade of Vita A3.5. Group C (Control) was used as a control without any surface characterization. The 4 groups were subjected to mechanical toothbrushing using a 1:1 water-to-toothpaste solution for a simulated duration of 32 years of clinical use. The amount of wear was measured at time intervals simulating every 4 years of toothbrushing. These parameters were evaluated longitudinally for all groups as well as compared at similar time points among groups. In this study, the novel external characterization technique (stain+LFP: Group SL) did not significantly enhance the wear resistance against toothbrush abrasion. Instead, the average wear of the applied extrinsic porcelain was 2 to 3 times more than Group S (stain only) and Group GS (glaze over stain). Application of a glaze layer over the colorants (Group GS) showed a significant improvement on wear resistance. Despite its superior physical properties, the leucite reinforced ceramic core (Group C) showed 2 to 4 times more wear when compared with other test groups. A conventional external esthetic characterization technique of applying a glaze layer over the colorants (Group GS) significantly enhanced the surface wear resistance to toothbrush abrasion when compared with other techniques involving application of colorants only (Group S) or mixture of colorant and LFP (Group SL). The underlying core ceramic had significantly less wear resistance compared with all externally characterized specimens. The novel esthetic characterization technique showed more wear and less color stability, and is thus not advocated as the "best" method for surface characterization. Application of a glaze layer provides a more wear-resistant surface from toothbrush abrasion when adjusting or extrinsically characterizing leucite reinforced ceramic restorations. Without the glaze layer, the restoration is subjected to a 2 to 4 times faster rate and amount of wear leading to possible shade mismatch.

  19. Effect of fiber addition on slow crack growth of a dental porcelain.

    PubMed

    de Araújo, Maico Dutra; Miranda, Ranulfo Benedito de Paula; Fredericci, Catia; Yoshimura, Humberto Naoyuki; Cesar, Paulo Francisco

    2015-04-01

    To evaluate the effect of the processing method (conventional sintering, S, and heat-pressing, HP) and addition of potassium titanate fibers, PTF, on the microstructure, mechanical properties (flexural strength, σf, and Weibull parameters, m and σ5%), slow crack growth parameters n (stress corrosion susceptibility coefficient), and optical properties (translucency parameter, TP, and opalescence index, OI) of a feldsphatic dental porcelain. Disks (n = 240, Ø12 × 1 mm) of porcelain (Vintage-Halo, Shofu) were produced using S and HP methods with and without addition of 10 wt% (conventional sintering) or 5 wt% (heat-pressing) of PTF. For the S method, porcelain was sintered in a conventional furnace. In the HP technique, refractory molds were produced by lost wax technique. The porcelain slurry was dry-pressed (3t/30s) to form a cylinder with 12 mm (diameter) and 20mm (height), which was heat-pressed for 5 min/3.5 bar into the mold. Specimens were tested for biaxial flexural strength in artificial saliva at 37°C. Weibull analysis was used to determine m and σ5%. Slow crack growth (SCG) parameters were determined by the dynamic fatigue test, and specimens were tested in biaxial flexure at five stress rates: 10(-2), 10(-1), 10(0), 10(1) and 10(2)MPa/s (n=10), immersed in artificial saliva at 37°C. Parameter n was calculated and statistically analyzed according to ASTM F394-78. Optical properties were determined in a spectrophotometer in the diffuse reflectance mode. The highest n value was obtained by the combination of heat-pressing with fiber addition (37.1) and this value was significantly higher than those obtained by both sintered groups (26.2 for control group and 27.7 for sintered with fiber). Although heat-pressing alone also resulted in higher n values compared to the sintered groups, there were no significant differences among them. Fiber addition had no effect on mechanical strength, but it resulted in decreased TP values and increased OI values for both processing methods. Heat-pressing alone was able to reduce the porosity level of the porcelain. Addition of PTF combined with heat-pressing can reduce strength degradation of a dental porcelain compared to sintered materials with or without fibers. Heat-pressing (HP) alone should be considered as a good alternative for clinical cases where high translucency is required. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Effectiveness and Safety of Transcatheter Aortic Valve Implantation for Aortic Stenosis in Patients With "Porcelain" Aorta.

    PubMed

    Ramirez-Del Val, Fernando; Hirji, Sameer A; Yammine, Maroun; Ejiofor, Julius I; McGurk, Siobhan; Norman, Anthony; Shekar, Prem; Aranki, Sary; Bhatt, Deepak L; Shah, Pinak; Cohn, Lawrence H; Kaneko, Tsuyoshi

    2018-01-01

    Surgical aortic valve replacement (SAVR) in patients with porcelain aorta is considered a high-risk procedure. Hence, transcatheter aortic valve implantation (TAVI) is emerging as the intervention of choice. However, there is a paucity of data directly comparing TAVI with SAVR in patients with porcelain aorta. We compared outcomes of TAVI versus SAVR in high-risk patients with porcelain between March 2012 and June 2015. The TAVI group included 54 patients, whereas 130 SAVR patients with porcelain aorta were identified (operated on between 2004 and 2015). Both groups were matched 1:1 based on the Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score with a 0.5% a priori caliper, resulting in 52 matched pairs. The mean STS-PROM was 7.3 ± 3.9 for both groups (p = 0.98), whereas mean age was 77.5 years for TAVI and 78.8 years for SAVR (p = 0.46). Compared with SAVR, TAVI patients had lower operative mortality (3.8% vs 17.3%; p = 0.052), significantly shorter median intensive care unit (40 vs 107 hours; p < 0.001) and hospital (5 vs. 7 days; p < 0.001) length of stay (LOS), but similar postoperative stroke rates (7.7% vs 11.5%; p = 0.74). One-year unadjusted survival was 81.7% (95% confidence interval [CI]: 69.8% to 93.5%) in the TAVI group versus 71.2% (95% CI: 61.0% to 85.1%) in the SAVR group, p = 0.093. Cox proportional hazard modeling identified preoperative chronic kidney disease (hazard ratio: 2.63 [95% CI: 1.03 to 6.70]; p = 0.043) and SAVR (hazard ratio: 2.641 [95% CI: 1.07 to 6.51]; p = 0.035) as significant predictors for decreased survival. Overall, TAVI was associated with reduced operative mortality, increased survival, and shorter intensive care unit and hospital length of stay compared with SAVR in patients with porcelain aorta. This study demonstrates that TAVI is a safe intervention in this high-risk population. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Influence of porcelain firing and cementation on the marginal adaptation of metal-ceramic restorations prepared by different methods.

    PubMed

    Kaleli, Necati; Saraç, Duygu

    2017-05-01

    Marginal adaptation plays an important role in the survival of metal-ceramic restorations. Porcelain firings and cementation may affect the adaptation of restorations. Moreover, conventional casting procedures and casting imperfections may cause deteriorations in the marginal adaptation of metal-ceramic restorations. The purpose of this in vitro study was to compare the marginal adaptation after fabrication of the framework, porcelain application, and cementation of metal-ceramic restorations prepared by using the conventional lost-wax technique, milling, direct metal laser sintering (DMLS), and LaserCUSING, a direct process powder-bed system. Alterations in the marginal adaptation of the metal frameworks during the fabrication stages and the precision of fabrication methods were evaluated. Forty-eight metal dies simulating prepared premolar and molar abutment teeth were fabricated to investigate marginal adaptation. They were divided into 4 groups (n=12) according to the fabrication method used (group C serving as the control group: lost-wax method; group M: milling method; group LS: DMLS method; group DP: direct process powder-bed method). Sixty marginal discrepancy measurements were recorded separately on each abutment tooth after fabrication of the framework, porcelain application, and cementation by using a stereomicroscope. Thereafter, each group was divided into 3 subgroups according to the measurements recorded in each fabrication stage: subgroup F (framework), subgroup P (porcelain application), and subgroup C (cementation). Data were statistically analyzed with univariate analysis of variance (followed by 1-way ANOVA and Tamhane T2 test (α=.05). The lowest marginal discrepancy values were observed in restorations prepared by using the direct process powder-bed method, and this was significantly different (P<.001) from the other methods. The highest marginal discrepancy values were recorded after the cementation procedure in all groups. The results showed that the direct process powder-bed method is quite successful in terms of marginal adaptation. The marginal discrepancy increased after porcelain application and cementation. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Resin cements formulated with thio-urethanes can strengthen porcelain and increase bond strength to ceramics.

    PubMed

    Bacchi, Atais; Spazzin, Aloisio Oro; de Oliveira, Gabriel Rodrigues; Pfeifer, Carmem; Cesar, Paulo Francisco

    2018-06-01

    The use of thio-urethane oligomers has been shown to significantly improve the mechanical properties of resin cements (RCs). The aim of this study was to use thio-urethane-modified RC to potentially reinforce the porcelain-RC structure and to improve the bond strength to zirconia and lithium disilicate. Six oligomers were synthesized by combining thiols - pentaerythritol tetra-3-mercaptopropionate (PETMP, P) or trimethylol-tris-3-mercaptopropionate (TMP, T) - with di-functional isocyanates - 1,6-Hexanediol-diissocyante (HDDI) (aliphatic, AL) or 1,3-bis(1-isocyanato-1-methylethyl)benzene (BDI) (aromatic, AR) or Dicyclohexylmethane 4,4'-Diisocyanate (HMDI) (cyclic, CC). Thio-urethanes (20 wt%) were added to a BisGMA/UDMA/TEGDMA organic matrix. Filler was introduced at 60 wt%. The microshear bond strength (μSBS), Weibull modulus (m), and failure pattern of RCs bonded to zirconia (ZR) and lithium disilicate (LD) ceramics was evaluated. Biaxial flexural test and fractographic analysis of porcelain discs bonded to RCs were also performed. The biaxial flexural strength (σ bf ) and m were calculated in the tensile surfaces of porcelain and RC structures (Z = 0 and Z = -t 2 , respectively). The μSBS was improved with RCs formulated with oligomers P_AL or T_AL bonded to LD and P_AL, P_AR or T_CC bonded to zirconia in comparison to controls. Mixed failures predominated in all groups. σ bf had superior values at Z = 0 with RCs formulated with oligomers P_AL, P_AR, T_AL, or T_CC in comparison to control; σ bf increased with all RCs composed by thio-urethanes at Z = -t 2 . Fractographic analysis revealed all fracture origins at Z = 0. The use of specific thio-urethane oligomers as components of RCs increased both the biaxial flexural strength of the porcelain-RC structure and the μSBS to LD and ZR. The current investigation suggests that it is possible to reinforce the porcelain-RC pair and obtain higher bond strength to LD and ZR with RCs formulated with selected types of thio-urethane oligomers. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Main Clinical Outcomes of Feldspathic Porcelain and Glass-Ceramic Laminate Veneers: A Systematic Review and Meta-Analysis of Survival and Complication Rates.

    PubMed

    Morimoto, Susana; Albanesi, Rafael Borges; Sesma, Newton; Agra, Carlos Martins; Braga, Mariana Minatel

    2016-01-01

    The aim of this study was to perform a systematic review and meta-analysis based on clinical trials that evaluated the main outcomes of glass-ceramic and feldspathic porcelain laminate veneers. A systematic search was carried out in Cochrane and PubMed databases. From the selected studies, the survival rates for porcelain and glass-ceramic veneers were extracted, as were complication rates of clinical outcomes: debonding, fracture/chipping, secondary caries, endodontic problems, severe marginal discoloration, and influence of incisal coverage and enamel/dentin preparation. The Cochran Q test and the I(2) statistic were used to evaluate heterogeneity. Out of the 899 articles initially identified, 13 were included for analysis. Metaregression analysis showed that the types of ceramics and follow-up periods had no influence on failure rate. The estimated overall cumulative survival rate was 89% (95% CI: 84% to 94%) in a median follow-up period of 9 years. The estimated survival for glass-ceramic was 94% (95% CI: 87% to 100%), and for feldspathic porcelain veneers, 87% (95% CI: 82% to 93%). The meta-analysis showed rates for the following events: debonding: 2% (95% CI: 1% to 4%); fracture/chipping: 4% (95% CI: 3% to 6%); secondary caries: 1% (95% CI: 0% to 3%); severe marginal discoloration: 2% (95% CI: 1% to 10%); endodontic problems: 2% (95% CI: 1% to 3%); and incisal coverage odds ratio: 1.25 (95% CI: 0.33 to 4.73). It was not possible to perform meta-analysis of the influence of enamel/dentin preparation on failure rates. Glass-ceramic and porcelain laminate veneers have high survival rates. Fracture/ chipping was the most frequent complication, providing evidence that ceramic veneers are a safe treatment option that preserve tooth structure.

  4. Preliminary assessment of metal-porcelain bonding strength of CoCrW alloy after 3wt.% Cu addition.

    PubMed

    Lu, Yanjin; Zhao, Chaoqian; Ren, Ling; Guo, Sai; Gan, Yiliang; Yang, Chunguang; Wu, Songquan; Lin, Junjie; Huang, Tingting; Yang, Ke; Lin, Jinxin

    2016-06-01

    In this work, a novel Cu-bearing CoCrW alloy fabricated by selective laser melting for dental application has been studied. For its successful application, the bonding strength of metal-porcelain is essential to be systematically investigated. Therefore, the aim of this study was to evaluate the metal-porcelain bonding strength of CoCrWCu alloy by three-point bending test, meanwhile the Ni-free CoCrW alloy was used as control. The oxygen content was investigated by an elemental analyzer; X-ray photoelectron spectroscopy (XPS) was used to analyze the surface chemical composition of CoCrW based alloy after preoxidation treatment; the fracture mode was investigated by X-ray energy spectrum analysis (EDS) and scanning electron microscope (SEM). Result from the oxygen content analysis showed that the content of oxygen dramatically increased after the Cu addition. And the XPS suggested that Co-oxidation, Cr2O3, CrO2, WO3, Cu2O and CuO existed on the preoxidated surface of the CoCrWCu alloy; the three-point bending test showed that the bonding strength of the CoCrWCu alloy was 43.32 MPa, which was lower than that of the CoCrW group of 47.65 MPa. However, the average metal-porcelain bonding strength is significantly higher than the minimum value in the ISO 9693 standard. Results from the SEM images and EDS indicated that the fracture mode of CoCrWCu-porcelain was mixed between cohesive and adhesive. Based on the results obtained in this study, it can be indicated that the Cu-bearing CoCrW alloy fabricated by the selective laser melting is a promising candidate for use in dental application. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Analyses of layer-thickness effects in bilayered dental ceramics subjected to thermal stresses and ring-on-ring tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsueh, Chun-Hway; Thompson, G. A.; Jadaan, Osama M.

    Objectives. The purpose of this study was to analyze the stress distribution through the thickness of bilayered dental ceramics subjected to both thermal stresses and ring-on-ring tests and to systematically examine how the individual layer thickness influences this stress distribution and the failure origin. Methods. Ring-on-ring tests were performed on In-Ceram Alumina/Vitadur Alpha porcelain bilayered disks with porcelain in the tensile side, and In-Ceram Alumina to porcelain layer thickness ratios of 1:2, 1:1, and 2:1 were used to characterize the failure origins as either surface or interface. Based on the thermomechanical properties and thickness of each layer, the cooling temperaturemore » from glass transition temperature, and the ring-on-ring loading configuration, the stress distribution through the thickness of the bilayer was calculated using closed-form solutions. Finite element analyses were also performed to verify the analytical results. Results. The calculated stress distributions showed that the location of maximum tension during testing shifted from the porcelain surface to the In-Ceram Alumina/porcelain interface when the relative layer thickness ratio changed from 1:2 to 1:1 and to 2:1. This trend is in agreement with the experimental observations of the failure origins. Significance. For bilayered dental ceramics subjected to ring-on-ring tests, the location of maximum tension can shift from the surface to the interface depending upon the layer thickness ratio. The closed-form solutions for bilayers subjected to both thermal stresses and ring-on-ring tests are explicitly formulated which allow the biaxial strength of the bilayer to be evaluated.« less

  6. Effect of Bonding Agent Application Method on Titanium-Ceramic Bond Strength.

    PubMed

    Curtis, Joseph G; Dossett, Jon; Prihoda, Thomas J; Teixeira, Erica C

    2015-07-01

    Although milled titanium may be used as a substructure in fixed and implant prosthodontics, the application of the veneering porcelain presents particular challenges compared to traditional alloys. To address these challenges, some Ti ceramic systems incorporate the application of a bonding agent prior to the opaque layer. Vita Titankeramik's bonding agent is available as a powder, paste, and spray-on formulation. We examined the effect of these three application methods on the bond strength. Four titanium bars were milled from each of 11 wafers cut from grade II Ti using the Kavo Everest milling unit and a custom-designed milling toolpath. An experienced technician prepared the 25 × 3 × 0.5 mm(3) metal bars and applied bonding agent using one of three application methods, and then applied opaque, dentin, and enamel porcelains according to manufacturer's instructions to a 8 × 3 × 1 mm(3) porcelain. A control group received no bonding agent prior to porcelain application. The four groups (n = 11) were blindly tested for differences in bond strength using a universal testing machine in a three-point bend test configuration, based on ISO 9693-1:2012. The average (SD) bond strengths for the control, powder, paste, and spray-on groups, respectively, were: 24.8 (2.6), 24.6 (2.6), 25.3 (4.0), and 24.1 (3.9) MPa. One-way ANOVA and Tukey's multiple comparison tests were performed between all groups. There were no statistically significant differences among groups (p = 0.951). Titanium-porcelain bond strength was not affected by the use of a bonding agent or its application method when tested by ISO 9693-1 standard. © 2014 by the American College of Prosthodontists.

  7. Flexural strength and failure modes of layered ceramic structures.

    PubMed

    Borba, Márcia; de Araújo, Maico D; de Lima, Erick; Yoshimura, Humberto N; Cesar, Paulo F; Griggs, Jason A; Della Bona, Alvaro

    2011-12-01

    To evaluate the effect of the specimen design on the flexural strength (σ(f)) and failure mode of ceramic structures, testing the hypothesis that the ceramic material under tension controls the mechanical performance of the structure. Three ceramics used as framework materials for fixed partial dentures (YZ--Vita In-Ceram YZ; IZ--Vita In-Ceram Zirconia; AL--Vita In-Ceram AL) and two veneering porcelains (VM7 and VM9) were studied. Bar-shaped specimens were produced in three different designs (n=10): monolithic, two layers (porcelain-framework) and three layers (TRI) (porcelain-framework-porcelain). Specimens were tested for three-point flexural strength at 1MPa/s in 37°C artificial saliva. For bi-layered design, the specimens were tested in both conditions: with porcelain (PT) or framework ceramic (FT) layer under tension. Fracture surfaces were analyzed using stereomicroscope and scanning electron microscopy (SEM). Young's modulus (E) and Poisson's ratio (ν) were determined using ultrasonic pulse-echo method. Results were statistically analyzed by Kruskal-Wallis and Student-Newman-Keuls tests. Except for VM7 and VM9, significant differences were observed for E values among the materials. YZ showed the highest ν value followed by IZ and AL. YZ presented the highest σ(f). There was no statistical difference in the σ(f) value between IZ and IZ-FT and between AL and AL-FT. σ(f) values for YZ-PT, IZ-PT, IZ-TRI, AL-PT, AL-TRI were similar to the results obtained for VM7 and VM9. Two types of fracture mode were identified: total and partial failure. The mechanical performance of the specimens was determined by the material under tension during testing, confirming the study hypothesis. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  8. Effects of metal surface grinding at the porcelain try-in stage of fixed dental prostheses

    PubMed Central

    Kesim, Bülent; Gümüş, Hasan Önder; Dinçel, Mehmet; Erkaya, Selçuk

    2014-01-01

    PURPOSE This study was to evaluate the effect of grinding of the inner metal surface during the porcelain try-in stage on metal-porcelain bonding considering the maximum temperature and the vibration of samples. MATERIALS AND METHODS Ninety-one square prism-shaped (1 × 1 × 1.5 mm) nickel-chrome cast frameworks 0.3 mm thick were prepared. Porcelain was applied on two opposite outer axial surfaces of the frameworks. The grinding was performed from the opposite axial sides of the inner metal surfaces with a low-speed handpiece with two types of burs (diamond, tungsten-carbide) under three grinding forces (3.5 N, 7 N, 14 N) and at two durations (5 seconds, 10 seconds). The shear bond strength (SBS) test was performed with universal testing machine. Statistical analyzes were performed at 5% significance level. RESULTS The samples subjected to grinding under 3.5 N showed higher SBS values than those exposed to grinding under 7 N and 14 N (P<.05). SBS values of none of the groups differed from those of the control group (P>.05). The types of bur (P=.965) and the duration (P=.679) did not affect the SBS values. On the other hand, type of bur, force applied, and duration of the grinding affected the maximum temperatures of the samples, whereas the maximum vibration was affected only by the type of bur (P<.05). CONCLUSION Grinding the inner metal surface did not affect the metal-porcelain bond strength. Although the grinding affected the maximum temperature and the vibration values of the samples, these did not influence the bonding strength. PMID:25177476

  9. The effect of a ceramic coating on the cpTi-porcelain bond strength.

    PubMed

    Papadopoulos, Triantafillos D; Spyropoulos, Konstantin D

    2009-02-01

    To investigate the bond strength between cpTi and low fusing porcelains after different treatments. 72 patterns were covered with a ceramic coating and invested with phosphate-bonded material (group A), another 72 were invested with magnesia material (group B) and all cast with cpTi. 31 solid castings were selected from each group. The castings of group B were ground and sandblasted, while the castings of group A were only sandblasted. Aluminum content of the metal surface was determined by EDS and castings were submitted to a 3-point bending test to determine the modulus of elasticity (E). The porcelains Duceratin Plus, Noritake Ti22 and Triceram were applied respectively and specimens were submitted to a 3-point bending test. The fracture mode and the remaining porcelain were determined by optical microscopy and SEM/EDS. Bond strength and fracture mode were calculated by two-way ANOVA. The E of groups A and B was 98.3 GPa and 98.6 GPa respectively. The bond strength was 26+/-3 MPa (Duceratin Plus), 28+/-3 MPa (Noritake Ti22), 27+/-2 MPa (Triceram) for group A and 24+/-1 MPa, 29+/-2 MPa, 27+/-1 MPa for group B respectively. No significant differences were found for the same porcelain between the two groups (p<0.05). A significant difference was found between Duceratin Plus and Noritake Ti22, for group B (p<0.05). The mode of failure was mainly adhesive for all specimens. A significant reduction in aluminum was recorded in all subgroups. The special coating of patterns makes the Ti casting procedure inexpensive, without reducing the metal-ceramic bond strength.

  10. Sol-gel dip coating of yttria-stabilized tetragonal zirconia dental ceramic by aluminosilicate nanocomposite as a novel technique to improve the bonding of veneering porcelain.

    PubMed

    Madani, Azamsadat; Nakhaei, Mohammadreza; Karami, Parisa; Rajabzadeh, Ghadir; Salehi, Sahar; Bagheri, Hossein

    2016-01-01

    The aim of this in vitro study was to evaluate the effect of silica and aluminosilicate nanocomposite coating of zirconia-based dental ceramic by a sol-gel dip-coating technique on the bond strength of veneering porcelain to the yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) in vitro. Thirty Y-TZP blocks (10 mm ×10 mm ×3 mm) were prepared and were assigned to four experimental groups (n=10/group): C, without any further surface treatment as the control group; S, sandblasted using 110 μm alumina powder; Si, silica sol dip coating + calcination; and Si/Al, aluminosilicate sol dip coating + calcination. After preparing Y-TZP samples, a 3 mm thick layer of the recommended porcelain was fired on the coated Y-TZP surface. Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy-dispersive X-ray analysis were used to characterize the coating and the nature of the bonding between the coating and zirconia. To examine the zirconia-porcelain bond strength, a microtensile bond strength (μTBS) approach was chosen. FT-IR study showed the formation of silica and aluminosilicate materials. XRD pattern showed the formation of new phases consisting of Si, Al, and Zr in coated samples. SEM showed the formation of a uniform coating on Y-TZP samples. Maximum μTBS values were obtained in aluminosilicate samples, which were significantly increased compared to control and sandblasted groups (P=0.013 and P<0.001, respectively). This study showed that aluminosilicate sol-gel dip coating can be considered as a convenient, less expensive reliable method for improving the bond strength between dental Y-TZP ceramics and veneering porcelain.

  11. Sol–gel dip coating of yttria-stabilized tetragonal zirconia dental ceramic by aluminosilicate nanocomposite as a novel technique to improve the bonding of veneering porcelain

    PubMed Central

    Madani, Azamsadat; Nakhaei, Mohammadreza; Karami, Parisa; Rajabzadeh, Ghadir; Salehi, Sahar; Bagheri, Hossein

    2016-01-01

    The aim of this in vitro study was to evaluate the effect of silica and aluminosilicate nanocomposite coating of zirconia-based dental ceramic by a sol–gel dip-coating technique on the bond strength of veneering porcelain to the yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) in vitro. Thirty Y-TZP blocks (10 mm ×10 mm ×3 mm) were prepared and were assigned to four experimental groups (n=10/group): C, without any further surface treatment as the control group; S, sandblasted using 110 μm alumina powder; Si, silica sol dip coating + calcination; and Si/Al, aluminosilicate sol dip coating + calcination. After preparing Y-TZP samples, a 3 mm thick layer of the recommended porcelain was fired on the coated Y-TZP surface. Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy-dispersive X-ray analysis were used to characterize the coating and the nature of the bonding between the coating and zirconia. To examine the zirconia–porcelain bond strength, a microtensile bond strength (μTBS) approach was chosen. FT-IR study showed the formation of silica and aluminosilicate materials. XRD pattern showed the formation of new phases consisting of Si, Al, and Zr in coated samples. SEM showed the formation of a uniform coating on Y-TZP samples. Maximum μTBS values were obtained in aluminosilicate samples, which were significantly increased compared to control and sandblasted groups (P=0.013 and P<0.001, respectively). This study showed that aluminosilicate sol–gel dip coating can be considered as a convenient, less expensive reliable method for improving the bond strength between dental Y-TZP ceramics and veneering porcelain. PMID:27478376

  12. Gingival health associated with porcelain veneers on maxillary incisors.

    PubMed

    Reid, J S; Kinane, D F; Adonogianaki, E

    1991-12-01

    The possible detrimental effect of acid-etched resin-bonded prostheses and porcelain veneers on plaque accumulation and gingival health is currently disputed. Some workers recommend no tooth preparation prior to veneering whilst others recommend tooth preparation to prevent adverse gingival soft tissue reactions. In order to test the possible gingival effects of veneers placed without tooth preparation, this study was set up to compare gingival health on veneered and non-veneered maxillary incisors within the same individual during periods of normal tooth cleaning and of no tooth cleaning. No significant differences were noted in plaque or gingival indices, or in gingival crevicular fluid volume, between the 72 veneered and non-veneered sites during either study period. The results of this study suggest that placing porcelain veneers on unprepared teeth does not increase the risk of gingivitis.

  13. Study on the method of improving the flashover voltage of 110kV suspension porcelain insulators based on neural network genetic algorithm

    NASA Astrophysics Data System (ADS)

    Zhang, Ruiqi; Cai, Li; Chen, Junwu; Wang, Luo; Tan, Xuefeng

    2018-04-01

    This paper presents a new method to improve 110kV porcelain insulator flashover voltage by adding a metal ring on the insulator cap, which can not only effectively reduce the field strength of the steel cap, but also reduce the tangential field intensity of the umbrella group and inhibit the development of the discharge process, thus the flashover voltage can be increased. The surface strength calculation model of 110kV porcelain insulator is established by the finite element method (FEM), and the parameters of the metal ring are designed by neural network genetic algorithm (BP-GA). Then the experiments were carried out to verify the results, and the results show that the metal ring plate under the optimum parameters can greatly improve the flashover voltage.

  14. Radiological impact assessment to the environment due to waste from disposal of porcelain.

    PubMed

    Morsi, Tarek; Hegazy, Rehab; Badawy, Wael

    2017-06-01

    The present study aimed to assess the radiological parameters from gamma rays due to the uncontrolled disposal of porcelain waste to the environment. Qualitative and quantitative identification of radionuclides in the investigated samples was carried out by means of a high-purity germanium (HPGe) detector. The average activity concentrations of the local porcelain samples were measured as 208.28 Bq/kg for 226 Ra, 125.73 Bq/kg for 238 U, 84.94 Bq/kg for 232 Th and 1033.61 Bq/kg for 40 K, respectively. The imported samples had an average activity of 240.57 Bq/kg for 226 Ra, 135.56 Bq/kg for 238 U, 115.74 Bq/kg for 232 Th and 1312.49 Bq/kg for 40 K, respectively. Radiological parameters and the radium equivalent Ra eq for the investigated samples were calculated. The external and internal hazard indices, representative level index (I γ ), alpha index (I α ), and the exemption level (I x ), were estimated to be higher than the recommended value (unity), while the average activity concentrations for the studied samples were higher than recommended levels. In conclusion, we are concerned that disposal of porcelain in the environment might be a significant hazard.

  15. Mössbauer study of the firing technology of the moon-white Jun porcelain in Chinese Yuan Dynasty

    NASA Astrophysics Data System (ADS)

    Songhua, Chen; Zhengyao, Gao; Zhongtian, Sun; Xiande, Chen

    1994-12-01

    The moon-white Jun porcelain glaze contains Fe2O3, Fe3O4 and structural iron. The firing atmosphere of ancient Jun kilns was modestly reductive. The firing temperature was slightly above 1250 ‡C. The glaze color appears moon-white, and is related to the low concentration of Fe2+. The coordination numbers of Fe2+ and Fe3+ are both 4.

  16. Dental Porcelain Furnaces: Test and Evaluation.

    DTIC Science & Technology

    1988-01-01

    D Q)L a ) a) C ) C C C C c *. . 3a)0. >4 a)->4 >4 -, Z 0 -a-’- 4-% a) ( nca )m m nU Cs C ) (3 ) 11) a) a) a3) Q) a) W) a2) C C~~ >4 L > > >1 >1 4 > 4...Fig. 1) is a computerized programmable porcelain furnace with 45 open programs. This unit has a large detachable cathode -ray tube (CRT) screen which

  17. Influence of bruxism on survival of porcelain laminate veneers.

    PubMed

    Granell-Ruíz, Maria; Agustín-Panadero, Rubén; Fons-Font, Antonio; Román-Rodríguez, Juan-Luis; Solá-Ruíz, María-Fernanda

    2014-09-01

    This study aims to determine whether bruxism and the use of occlusal splints affect the survival of porcelain laminate veneers in patients treated with this technique. Restorations were made in 70 patients, including 30 patients with some type of parafunctional habit. A total of 323 veneers were placed, 170 in patients with bruxism activity, and the remaining 153 in patients without it. A clinical examination determined the presence or absence of ceramic failure (cracks, fractures and debonding) of the restorations; these incidents were analyzed for association with bruxism and the use of splints. Analysis of the ceramic failures showed that of the 13 fractures and 29 debonding that were present in our study, 8 fractures and 22 debonding were related to the presence of bruxism. Porcelain laminate veneers are a predictable treatment option that provides excellent results, recognizing a higher risk of failure in patients with bruxism activity. The use of occlusal splints reduces the risk of fractures.

  18. The study of chemical composition and elemental mappings of colored over-glaze porcelain fired in Qing Dynasty by micro-X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Lin, Cheng; Meitian, Li; Youshi, Kim; Changsheng, Fan; Shanghai, Wang; Qiuli, Pan; Zhiguo, Liu; Rongwu, Li

    2011-02-01

    It is very difficult to measure the chemical composition of colored pigments of over-glaze porcelain by X-ray fluorescence because it contains high concentration of Pb. One of the disadvantages of our polycapillary optics is that it has low transmission efficiency to the high energy X-ray. However, it is beneficial to measure the chemical compositions of rich Pb sample. In this paper, we reported the performances of a tabletop setup of micro-X-ray fluorescence system base on slightly focusing polycapillary and its applications for analysis of rich Pb sample. A piece of Chinese ancient over-glaze porcelain was analyzed by micro-X-ray fluorescence. The experimental results showed that the Cu, Fe and Mn are the major color elements. The possibilities of the process of decorative technology were discussed in this paper, also.

  19. A conservative approach for treating young adult patients with porcelain laminate veneers.

    PubMed

    Chen, Yen-Wei; Raigrodski, Ariel J

    2008-01-01

    Controversy persists regarding the treatment planning criteria for young adult patients in need of esthetic restorations. The trend of conservative treatment modalities continues to become widely acknowledged. One of the conservative treatment modalities is porcelain laminate veneers (PLVs). PLVs not only provide suitable esthetics but also reliable functional strength. This article presents two anterior esthetic cases to demonstrate a conservative treatment planning approach and its application as a nontraditional solution for young adult patients. It is recommended that a conservative approach be used wherever possible as an alternative to treatment options that may aggressively sacrifice tooth structure as well as the health of the supporting tissues. By using a conservative approach to treatment with porcelain veneers, long-lasting, esthetic, and functional results may be achieved. Sacrificing as little tooth structure as possible and conserving the supporting tissues will facilitate prospective treatments for young adult patients.

  20. Further studies on gold alloys used in fabrication of porcelain-fused-to-metal restorations.

    PubMed

    Civjan, S; Huget, E F; Dvivedi, N; Cosner, H J

    1975-03-01

    Composition, microstructure, castability, mechanical properties, and heat treatment characteristics of two gold-palladium-silver-based alloys were studied. The materials exhibited compositional as well as microstructural differences. Clinically acceptable castings could not be obtained when manufacturers' recommended casting temperatures were used. Ultimate tensile strength, yield strength, modulus of elasticity, and Brinell hardness values for the alloys were comparable. The elastic limit of Cameo, however, was significantly higher than that of vivo-star. Maximum rehardening of annealed castings occurred on reheat treatment at temperatures between 1,200 and 1,300 F. As-cast specimens, however, were not heat hardenable. The sequence of heat treatments used in the application of porcelain reduced slightly the hardness of both alloys. Hardness of the metal substructures was not increased by return of porcelain-coated specimens to a 1,250 F oven for final heat treatment.

  1. Bond strength of the porcelain repair system to all-ceramic copings and porcelain.

    PubMed

    Lee, Sang J; Cheong, Chan Wook; Wright, Robert F; Chang, Brian M

    2014-02-01

    The purpose of this study was to investigate the shear bond strength of the porcelain repair system on alumina and zirconia core ceramics, comparing this strength with that of veneering porcelain. Veneering ceramic (n = 12), alumina core (n = 24), and zirconia core (n = 24) blocks measuring 10 × 5 × 5 mm(3) were fabricated. Veneering ceramic blocks were used as the control. Alumina and zirconia core blocks were divided into 2 groups (n = 12 each), and a slot (2 × 2 × 4 mm(3)) filled with veneering ceramics was prepared into one of the alumina and zirconia core groups (n = 12). Followed by surface treatments of micro-abrasion with 30 μm alumina particles, etching with 35% phosphoric acid and silane primer and bond, composite resin blocks (2 × 2 × 2 mm(3)) were built up and light polymerized onto the treated surfaces by 3 configurations: (a) composite blocks bonded onto veneering ceramic surface alone, (b) composite blocks bonded onto alumina core or zirconia core surfaces, (c) a 50% surface area of the composite blocks bonded to veneering ceramics and the other 50% surface area of the composite blocks to alumina core or zirconia core surfaces. The shear bond strength of the composite to each specimen was tested by a universal testing machine at a 0.5 mm/min crosshead speed. The shear bond strength was analyzed by unpaired t-tests for within the configuration groups and ANOVA for among the different configuration groups. When the mean shear bond strength was compared within groups of the same configuration, there were no statistically significant differences. Comparison of the shear bond strength among groups of different configurations revealed statistically significant differences. The mean shear bond strength of composite onto 100% veneering ceramic surface and composite onto 50% veneering 50% all-ceramic cores was statistically higher than that of composite onto 100% all-ceramic cores; however, the differences of the shear bond strength of composite bonded only onto the veneering ceramic surface were not statistically significant from those of 50% surface area of composite bonded onto all-ceramic cores. No statistically significant differences in the bond strength of a porcelain repair system to alumina and zirconia copings were observed. Increasing the surface of veneering ceramics to a porcelain repair system improved the repair material's bond strength. © 2013 by the American College of Prosthodontists.

  2. Diminutive Porcelain Ascending Aorta With Supravalvular Aortic Stenosis.

    PubMed

    Houmsse, Mustafa; McDavid, Asia; Kilic, Ahmet

    2018-05-01

    This report describes the case of a 49-year-old man with a medical history significant for congenital aortic stenosis. The patient presented with progressive shortness of breath and decreased stamina and was found to have a concentric, diminutive porcelain ascending aorta with diffuse supravalvular aortic stenosis. We describe treatment with an aortic root augmentation and Bentall procedure using hypothermic circulatory arrest. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Influence of Different Post-Plasma Treatment Storage Conditions on the Shear Bond Strength of Veneering Porcelain to Zirconia

    PubMed Central

    Lee, Mun-Hwan; Min, Bong Ki; Son, Jun Sik; Kwon, Tae-Yub

    2016-01-01

    This in vitro study investigated whether different storage conditions of plasma-treated zirconia specimens affect the shear bond strength of veneering porcelain. Zirconia plates were treated with a non-thermal atmospheric argon plasma (200 W, 600 s). Porcelain veneering (2.38 mm in diameter) was performed immediately (P-I) or after 24 h storage in water (P-W) or air (P-A) on the treated surfaces (n = 10). Untreated plates were used as the control. Each group was further divided into two subgroups according to the application of a ceramic liner. All veneered specimens underwent a shear bond strength (SBS) test. In the X-ray photoelectron spectroscopy (XPS) analysis, the oxygen/carbon ratios of the plasma-treated groups increased in comparison with those of the control group. When a liner was not used, the three plasma-treated groups showed significantly higher SBS values than the control group (p < 0.001), although group P-A exhibited a significantly lower value than the other two groups (p < 0.05). The liner application negatively affected bonding in groups P-I and P-W (p < 0.05). When the veneering step was delayed after plasma treatment of zirconia, storage of the specimens in water was effective in maintaining the cleaned surfaces for optimal bonding with the veneering porcelain. PMID:28787841

  4. [Effect of pigmentation on the strength of dental Y-TZP/porcelain bilayered structure].

    PubMed

    Ma, Ting-ting; Yi, Yuan-fu; Shao, Long-quan; Liu, Hong-chen; Tian, Jie-mo; Hou, Kang-lin; Zhang, Wei-wei; Wen, Ning; Deng, Bin

    2010-05-01

    To investigate the effect of two methods of pigmentation on the flexural strength of dental Y-TZP/porcelain layered structure. KaVo zirconia substructures were pigmented by dipping presintered blocks in the coloring solution VITA LL1 and LL5, and colored TZ-3YS zirconia substructures were fabricated by adding pigments before isostatic pressing. The colors No.1 and No.5 were used for the test. The specimens were made in monolithic or bilayered forms, and the flexural strength was tested. XRD and SEM with EDX were used to analyze the characteristics of the surface structure. In KaVo group, no significant differences were found in the flexural strength between white and LL1 and LL5 colored monoclinic materials, nor in bilayered structures. While in TZ-3YS group, significant differences were noted in the flexural strength between color No.5 white and color No.1 monoclinic materials, but not between the latter two subgroups. The flexural strength was significantly lowered by veneering with porcelain in both zirconia groups, and similar findings were observed with the monoclinic materials. Only the tetragonal phase was detected in both of the zirconia groups. Pigmentation has no apparent effects on the bonding strength between the veneering porcelain and zirconia. Both coloring methods are appropriate when the concentration of the pigments is under deliberate control.

  5. The effect of remin pro and MI paste plus on bleached enamel surface roughness.

    PubMed

    Ahmad Akhoundi, Mohammad Sadegh; Aghajani, Farzaneh; Chalipa, Javad; Sadrhaghighi, Amir Hooman

    2014-03-01

    Increased number of adult patients requesting orthodontic treatment result in bonding bracket to ceramic restorations more than before. The aim of this study was to evaluate and compare the shear bond strength of orthodontic brackets bonded to two types of ceramic bases with conventional orthodontic bonding resin and a new nano-filled composite resin. Twenty four feldespathic porcelain and 24 lithium disilicate ceramic disks were fabricated. All of the samples were conditioned by sandblasting, hydrofluoric acid and silane. Maxillary incisor metal brackets were bonded to half of the disks in each group by conventional orthodontic bonding resin and the other half bonded with a nano-filled composite. The samples then were thermocycled for 2000 cycle between 5-55° C. Shear bond strength was measured and the mode of failure was examined. Randomly selected samples were also evaluated by SEM. The lowest bond strength value was found infeldespathic ceramic bonded by nano-filled composite (p<0.05). There was not any statistically significant difference between other groups regarding bond strength. The mode of failure in the all groups except group 1 was cohesive and porcelain damages were detected. Since less damages to feldspathic porcelain was observed when the nano-filled composite was used to bond brackets, the use of nano-filled composite resins can be suggested for bonding brackets to feldspathic porcelain restorations.

  6. The Effect of Remin Pro and MI Paste Plus on Bleached Enamel Surface Roughness

    PubMed Central

    Ahmad Akhoundi, Mohammad Sadegh; Aghajani, Farzaneh; Chalipa, Javad; Sadrhaghighi, Amir Hooman

    2014-01-01

    Objective Increased number of adult patients requesting orthodontic treatment result in bonding bracket to ceramic restorations more than before. The aim of this study was to evaluate and compare the shear bond strength of orthodontic brackets bonded to two types of ceramic bases with conventional orthodontic bonding resin and a new nano-filled composite resin. Materials and Methods: Twenty four feldespathic porcelain and 24 lithium disilicate ceramic disks were fabricated. All of the samples were conditioned by sandblasting, hydrofluoric acid and silane. Maxillary incisor metal brackets were bonded to half of the disks in each group by conventional orthodontic bonding resin and the other half bonded with a nano-filled composite. The samples then were thermocycled for 2000 cycle between 5–55° C. Shear bond strength was measured and the mode of failure was examined. Randomly selected samples were also evaluated by SEM. Results: The lowest bond strength value was found infeldespathic ceramic bonded by nano-filled composite (p<0.05). There was not any statistically significant difference between other groups regarding bond strength. The mode of failure in the all groups except group 1 was cohesive and porcelain damages were detected. Conclusion: Since less damages to feldspathic porcelain was observed when the nano-filled composite was used to bond brackets, the use of nano-filled composite resins can be suggested for bonding brackets to feldspathic porcelain restorations. PMID:24910698

  7. Indentation fracture toughness and dynamic elastic moduli for commercial feldspathic dental porcelain materials.

    PubMed

    Rizkalla, Amin S; Jones, Derek W

    2004-02-01

    The purpose of this study was to evaluate and compare the indentation fracture toughness, true hardness and dynamic elastic moduli for 14 commercial dental porcelain materials. The specimens were fired according to manufacturer instructions. The density of the specimens (n=3) was measured by means of the water displacement technique. Dynamic Young's shear and bulk moduli and Poisson's ratio (n=3) were measured using a non-destructive ultrasonic technique using 10 MHz lithium niobate crystals. The true hardness (n=3) was measured using a Knoop indenter and the fracture toughness (n=3) was determined using a Vickers indenter and a Tukon hardness tester. Statistical analysis of the data was conducted using ANOVA and a Student-Newman-Keuls (SNK) rank order multiple comparative test. The SNK rank test analysis for the mean dynamic Young's modulus and fracture toughness was able to separate 14 dental porcelain materials into seven and nine groups, respectively, at p=0.05. The elastic moduli, true hardness and indentation fracture toughness for opaque porcelains were significantly higher than incisal; and body materials at p=0.05. The indentation fracture toughness and the ultrasonic test methods exhibit lower coefficient of variation compared to conventional methods and have considerable advantage for ceramic dental materials in that only small specimens are required to produce an acceptable number of data for statistical analysis.

  8. Comparison of the bond strength of stainless steel orthodontic brackets bonded to crown porcelains.

    PubMed

    Chay, Siew Han; Wattanapayungkul, Pranee; Yap, Adrian U Jin; Loh, Poey Ling; Chung, Sew Meng

    2005-05-01

    The bond strengths and mode of failure of stainless steel orthodontic brackets bonded to the newer all-ceramic crown systems has not been fully investigated. To compare the shear-peel bond strengths and modes of failure of stainless steel Begg orthodontic brackets bonded to all-ceramic crown systems (Finesse, Empress II) and a conventional feldsphatic crown porcelain (Vita Omega 900). Fifteen flat-surface discs of three crown porcelains (Finesse, Vita Omega 900, Empress II) were made and mounted in acrylic moulds. The discs were pumiced, etched with phosphoric acid, primed with silane, and a flat stainless steel Begg bracket bonded to each disc with a chemical cure composite resin (Unite Bond). The discs were stored for one week in water and debonded with a sheer-peel load in an Instron uniaxial testing system with a crosshead speed of 0.5 mm/min. The composite remnants on the ceramic surfaces were classified using the Adhesive Remnant Index (ARI). The bond strength of Finesse (15.03 +/- 1.90 MPa) was significantly greater (p < 0.001) than Vita Omega 900 11.51 +/- 2.35 MPa) and Empress II (11.12 +/- 1.78 MPa). There were no significant differences among the ARI scores. The mode of failure was a mixture of adhesive and cohesive failure. The results indicate that the bond strengths of stainless steel orthodontic brackets bonded to Finesse and Empress II porcelains are clinically acceptable.

  9. Effect of feldspathic porcelain layering on the marginal fit of zirconia and titanium complete-arch fixed implant-supported frameworks.

    PubMed

    Yilmaz, Burak; Alshahrani, Faris A; Kale, Ediz; Johnston, William M

    2018-02-06

    Veneering with porcelain may adversely affect the marginal fit of long-span computer-aided design and computer-aided manufacturing (CAD-CAM) implant-supported fixed prostheses. Moreover, data regarding the precision of fit of CAD-CAM-fabricated implant-supported complete zirconia fixed dental prostheses (FDPs) before and after porcelain layering are limited. The purpose of this in vitro study was to evaluate the effect of porcelain layering on the marginal fit of CAD-CAM-fabricated complete-arch implant-supported, screw-retained FDPs with presintered zirconia frameworks compared with titanium. An autopolymerizing acrylic resin-fixed complete denture framework prototype was fabricated on an edentulous typodont master model (all-on-4 concept; Nobel Biocare) with 2 straight in the anterior and 2 distally tilted internal-hexagon dental implants in the posterior with multiunit abutments bilaterally in canine and first molar locations. A 3-dimensional (3D) laser scanner (S600 ARTI; Zirkonzahn) was used to digitize the prototype and the master model by using scan bodies to generate a virtual 3D CAD framework. Five presintered zirconia (ICE Zirkon Translucent - 95H16; Zirkonzahn) and 5 titanium (Titan 5 - 95H14; Zirkonzahn) frameworks were fabricated using the CAM milling unit (M1 Wet Heavy Metal Milling Unit; Zirkonzahn).The 1-screw test was applied by fixing the frameworks at the location of the maxillary left first molar abutment, and an industrial computed tomography (CT) scanner (XT H 225 - Basic Configuration; Nikon) was used to scan the framework-model complex to evaluate the passive fit of the frameworks on the master model. The scanned data were transported in standard tessellation language (STL) from Volume Graphics analysis software to PolyWorks analysis software by using the maximum-fit algorithm to fit scanned planes in order to mimic the mating surfaces in the best way. 3D virtual assessment of the marginal fit was performed at the abutment-framework interface at the maxillary right canine (gap 3) and right first molar (gap 4) abutments without prosthetic screws. The facial or buccal aspects of the teeth on frameworks were layered with corresponding porcelain (Initial Dental Ceramic System; GC) and CT-scanned again using the same protocol. Marginal fit measurements were made for 4 groups: titanium (Ti) (control), porcelain-layered titanium (Ti-P) (control), zirconia (Zr), and porcelain-layered zirconia (Zr-P). 3D discrepancy mean values were computed and calculated, and the results were analyzed with a repeated measures 3-way ANOVA using the maximum likelihood estimation method and Bonferroni adjustments for selected pairwise comparison t-tests (α=.05). The 3D fit was measured at gap 3 and gap 4. Statistically significant differences in mean 3D discrepancies were observed between Zr-P (175 μm) and Zr (89 μm) and between Zr-P and Ti-P (71 μm) (P<.001). Porcelain layering had a significant effect on the marginal fit of CAD-CAM-fabricated complete-arch implant-supported, screw-retained FDPs with partially sintered zirconia frameworks. 3D marginal discrepancy mean values for all groups were within clinically acceptable limits (<120 μm), except for the layered zirconia framework. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Effect of ZrO2 on the sintering behavior, strength and high-frequency dielectric properties of electrical ceramic porcelain insulator

    NASA Astrophysics Data System (ADS)

    Singh Mehta, Niraj; Sahu, Praveen Kumar; Ershad, Md; Saxena, Vipul; Pyare, Ram; Ranjan Majhi, Manas

    2018-01-01

    In the present study, the effect of ZrO2 on the sintering, strength and dielectric behavior of electrical ceramic porcelain insulator with substituting alumina content by zirconia (in weight percentage from 0% to 30%) is investigated. The different composition of samples containing different zirconia (ZrO2) contents of 0, 10, 20, and 30 wt% are prepared using the uniaxial pressure technique applying 160 MPa pressure. Further, the prepared samples are also analyzed for sintering temperatures (1350 °C), and effects are observed on mechanical and electric properties of porcelain insulator. Different characterizations such as Dilatometer, x-ray diffraction, scanning electron microscopy and differential thermal analysis/thermo gravimetric analysis were used to evaluate the thermal, phase detection, micro structural and weight loss changes by increasing concentration of ZrO2 on base porcelain composition. At 1350 °C, for the composition having 20 wt% ZrO2 with 10 wt% alumina, the maximum density was observed 2.81 g cm-3 with a porosity of 2.23%. The highest tensile strength of 41 ± 3 MPa is observed for the same sample composition. The minimum value of thermal expansion coefficient is found to be in the range of 10-6 for the sample with 30 wt% ZrO2 content sintered at 1350 °C compared to other prepared samples. Similarly, the highest dielectric value (5.1-4.4) having dielectric loss (0.08-0.12) is achieved for the sample with 30 wt% ZrO2 content sintered at 1350 °C in the frequency range of 4-20 GHz at room temperature. According to the mechanical properties, the composition having 20 wt% ZrO2 on base ceramic porcelain composition has enormous potential to serve as a high strength refractory material. For dielectric properties, the composition having 30 wt% ZrO2 is more suitable for the electrical application.

  11. Shear bond strength of metal brackets to feldspathic porcelain treated by Nd:YAG laser and hydrofluoric acid.

    PubMed

    Hosseini, Mohammad Hashem; Sobouti, Farhad; Etemadi, Ardavan; Chiniforush, Nasim; Shariati, Mahsa

    2015-02-01

    Adult orthodontic treatment requires bonding orthodontic attachment to dental restorations. Ceramics are commonly used as esthetic restorative materials for the crowns and bridges. The present study evaluated the shear bond strength of metal orthodontic brackets to the feldspathic porcelain surfaces following conditioning by different powers of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser and hydrofluoric acid as a conventional method. Seventy-two glazed porcelain samples were prepared and randomly attributed to six equal groups of 12. In the conventional hydrofluoric (HF) group, the specimens were etched by 9.6% hydrofluoric acid for 4 min. In laser groups, samples were conditioned by 0.75-, 1-, 1.25-, 1.5-, and 2-W Nd:YAG laser for 10 s. Metal brackets were bonded to porcelain samples and after being stored in distilled water for 24 h, they were subjected to thermocycling for 500 cycles. The debonding was carried out by a Zwick testing machine. The data were statistically analyzed by ANOVA and Tamhane multiple comparisons tests. The mean ± SD of the shear bond strength in the laser group 0.75, 1, 1.25, 1.5, and 2 W and HF group was 2.2 ± 0.9, 4.2 ± 1.1, 4.9 ± 2.4, 7 ± 1.7, 9.6 ± 2.7, and 9.4 ± 2.5, respectively. Together with the increased power of laser, the mean shear bond strength was increased continuously and no significant differences were found between the HF group and the laser groups with power of 1.5 or 2 W. Also, there was no significant difference between all test groups in ARI scores. There was no significant difference between bond strength of laser groups with power of 1.5 and 2 W and HF-etched group. So, Nd:YAG laser with appropriate parameters can be used as an alternative method for porcelain etching.

  12. The Effect of Marginal Seal of Veneering DiCor (trade name) Substrates with DiCor Plus Porcelain

    DTIC Science & Technology

    1991-05-01

    the Faculty of The University of Texas Graduate School of Biomedical Sciences at San Antonio in Partial Fulfillment of the Requirements LT’ for the...EFFECT ON MARGINAL SEAL OF VENEERING Dicor® SUBSTRATES WITH Dicor® PLUS PORCELAIN Regan Salamander, M.S. The University of Texas Graduate School of...Conversely, fatigue in ceramics is the subcritical growth of cracks aided by a combined influence of water and stress . It has been estimated that fatigue

  13. Porcelain Enamel Material Testing Procedures to Determine the Damping Properties and the Results of Selected Materials

    DTIC Science & Technology

    1980-09-01

    AFWAL-TR-80-41 16 a N0946 6 6 PORCELAIN ENAMEL MATERIAL TESTING PROCEDURES TO DETERMINE THE DAMPINGi l PROPERTIES AND THE RESULTS OF ,= SELECTED...15..DECLASSI FtCATION/ DOWNGRADING SCHEDULE N.A(U~~~~ ~N A. 7~ ~&:’? 16 . DISThmBUTTUSTATEMENT (o1 this Report) Approved for public release...Damping Fixture 15 Number One 6 High Temperature Enamels Damping Fixture 16 Number Two 7 Schematic of the Enamels Testing Furnace Showing 18 the

  14. Comparative analysis of the fit of 3-unit implant-supported frameworks cast in nickel-chromium and cobalt-chromium alloys and commercially pure titanium after casting, laser welding, and simulated porcelain firings.

    PubMed

    Tiossi, Rodrigo; Rodrigues, Renata Cristina Silveira; de Mattos, Maria da Glória Chiarello; Ribeiro, Ricardo Faria

    2008-01-01

    This study compared the vertical misfit of 3-unit implant-supported nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) alloy and commercially pure titanium (cpTi) frameworks after casting as 1 piece, after sectioning and laser welding, and after simulated porcelain firings. The results on the tightened side showed no statistically significant differences. On the opposite side, statistically significant differences were found for Co-Cr alloy (118.64 microm [SD: 91.48] to 39.90 microm [SD: 27.13]) and cpTi (118.56 microm [51.35] to 27.87 microm [12.71]) when comparing 1-piece to laser-welded frameworks. With both sides tightened, only Co-Cr alloy showed statistically significant differences after laser welding. Ni-Cr alloy showed the lowest misfit values, though the differences were not statistically significantly different. Simulated porcelain firings revealed no significant differences.

  15. [The influence of different opaque thickness on the bond strength of porcelain-fused-to metal restoration].

    PubMed

    Xu, Kan; He, Fan; Geng, Yi

    2009-12-01

    To study the influence of different opaque thickness on the bond strength of porcelain-fused-to metal (PFM) restorations. The testing sheets were made as the samples of ISO9693. With different sintering temperature and different opaque thickness on the bond strength of PFM restorations, the primary pressure of porcelain crack was measured by using three-points-bending test. Statistical analysis was carried out using a SPSS 10.0 software package. A post hoc multiple comparison test (Student-Newman-Keuls) was performed to evaluate the differences between the individual groups. In low sintering temperature group, the thin layer of opaque significantly improved the bond strength compared with thick layer of opaque (P<0.05). In high sintering temperature group, the thickness of opaque has no significant influence on the PFM bonding strength. Using the opaque, the bonding strength was better than those without opaque. The thickness of opaque has a little influence on the PFM bonding strength.

  16. [Study on corrosion resistance of three non-noble porcelain alloys].

    PubMed

    Wu, Zhikai; Xu, Sheng; Li, Wei; Teng, Jin; Li, Ning

    2011-10-01

    To study the electrochemical corrosion behavior of Co-Cr, Ni-Cr and Ni-Cr-Be based porcelain alloys in NaCl solution. Five samples of each alloy were made respectively, electric polarization curve of each alloy was obtained using potentiodynamic polarization technique. Self-corrosion potential (E(corr)), self-corrosion current density (I(corr), passive region and transpassivation potential were tested. Microstructure and constituent was examined using scanning electron microscopy and energy dispersive spectroscopy. Co-Cr alloy possessed the most desirable corrosion resistance because of its integrated, homogeneous and compact passive film. The poor compactness of Ni-Cr alloy's passive film decreased its corrosion resistance. Ni-Cr-Be alloy exhibited the worst corrosion resistance due to the Cr and Mo depleted Ni-Be eutectic phases in the alloy. Taking biological security into consideration, it is necessary to avoid the application of porcelain alloys with Be element. Co-Cr alloy with better biocompatibility possesses much broader prospect in the field of dental restoration.

  17. The effect of heat treatments applied to superstructure porcelain on the mechanical properties and microstructure of lithium disilicate glass ceramics.

    PubMed

    Özdemir, Hatice; Özdoğan, Alper

    2018-01-30

    The aim of this study was to investigate that heat treatments with different numbers applied to superstructure porcelain whether effects microstructure and mechanical properties of lithium disilicate ceramic (LDC). Eighty disc-shaped specimens were fabricated from IPS e.max Press. Specimens were fired at heating values of porcelain in different numbers and divided four groups (n=5). Initial Vickers hardness were measured and X-ray diffraction (XRD) analysis was performed. Different surface treatment were applied and then Vickers hardness, surface roughness and environmental scanning electron microscopy (ESEM) analysis were performed. Data were analyzed with Varyans analysis and Tukey HSD test (α=0.05). Initial hardness among groups was no significant different (p>0.05), but hardness and surface roughness after surface treatments were significant different (p<0.05). Lithium disilicate (LD) peaks decrease depended on firing numbers. ESEM observations showed that firing number and surface treatments effect microstructure of LDC. Increasing firing numbers and surface treatments effect the microstructure of LDC.

  18. Influence of bruxism on survival of porcelain laminate veneers

    PubMed Central

    Agustín-Panadero, Rubén; Fons-Font, Antonio; Román-Rodríguez, Juan L.; Solá-Ruíz, María F.

    2014-01-01

    Objectives: This study aims to determine whether bruxism and the use of occlusal splints affect the survival of porcelain laminate veneers in patients treated with this technique. Material and Methods: Restorations were made in 70 patients, including 30 patients with some type of parafunctional habit. A total of 323 veneers were placed, 170 in patients with bruxism activity, and the remaining 153 in patients without it. A clinical examination determined the presence or absence of ceramic failure (cracks, fractures and debonding) of the restorations; these incidents were analyzed for association with bruxism and the use of splints. Results: Analysis of the ceramic failures showed that of the 13 fractures and 29 debonding that were present in our study, 8 fractures and 22 debonding were related to the presence of bruxism. Conclusions: Porcelain laminate veneers are a predictable treatment option that provides excellent results, recognizing a higher risk of failure in patients with bruxism activity. The use of occlusal splints reduces the risk of fractures. Key words:Veneer, fracture, debonding, bruxism, occlusal splint. PMID:23986018

  19. Evaluation of shear bond strength of porcelain bonded to laser welded titanium surface and determination of mode of bond failure.

    PubMed

    Patil, Narendra P; Dandekar, Minal; Nadiger, Ramesh K; Guttal, Satyabodh S

    2010-09-01

    The aim of this study was to evaluate the shear bond strength of porcelain to laser welded titanium surface and to determine the mode of bond failure through scanning electron microscopy (SEM) and energy dispersive spectrophotometry (EDS). Forty five cast rectangular titanium specimens with the dimension of 10 mm x 8 mm x 1 mm were tested. Thirty specimens had a perforation of 2 mm diameter in the centre. These were randomly divided into Group A and B. The perforations in the Group B specimens were repaired by laser welding using Cp Grade II titanium wire. The remaining 15 specimens were taken as control group. All the test specimens were layered with low fusing porcelain and tested for shear bond strength. The debonded specimens were subjected to SEM and EDS. Data were analysed with 1-way analysis of variance and Student's t-test for comparison among the different groups. One-way analysis of variance (ANOVA) showed no statistically significant difference in shear bond strength values at a 5% level of confidence. The mean shear bond strength values for control group, Group A and B was 8.4 +/- 0.5 Mpa, 8.1 +/- 0.4 Mpa and 8.3 +/- 0.3 Mpa respectively. SEM/EDS analysis of the specimens showed mixed and cohesive type of bond failure. Within the limitations of the study laser welding did not have any effect on the shear bond strength of porcelain bonded to titanium.

  20. Influence of Alkali Resistant (Ar) Fibreglass in Porcelain Clay for Manufacturing Vitrified Clay Pipes

    NASA Astrophysics Data System (ADS)

    Ikhmal Hanapi, Muhammad; Ahmad, Sufizar; Taib, Hariati; Ismail, Al Emran; Nasrull Abdol Rahman, Mohd; Salleh, Salihatun Md; Sadikin, Azmahani; Mahzan, Shahruddin

    2017-10-01

    The aim of this work is to determine the characteristics of porcelain ceramic with influence of milled Alkali Resistant (AR) fiberglass for manufacturing vitrified clay pipes. In this study, raw materials consist of porcelain clay and AR fiberglass were refined into powders less than 90μm. Subsequently, these samples were compacted into cylindrical pellet for chemical analysis using X-Ray Fluorescence (XRF). The ceramic sample was produced by mixing different weight percentage of AR glass to porcelain ceramic with 3 wt%, 6 wt%, 9 wt% and 12 wt%. Subsequently, the sample was compacted with 3 ton of pressure load and sintered at 900 °C, 1000 °C, 1100 °C and 1200 °C. The phase identification by using X-Ray Diffraction (XRD) and microstructural analysis were performed for the sintered sample. Chemical analysis revealed that the significant element for all raw material are SiO2, Al2O3, Na2O and K2O. Phase identification analysis shown that sample sintered at 1000 °C produces quartz (SiO2), berlinite (AlPO4), albite (NaAlSi3O8) and calcium-magnesium-aluminum-silicate (CaMgAlSiO). The formation of primary mullite was observed in sample sintered at 1100 °C. The image of microstructural morphology denoted that the formation of glassy phase with decreasing amount of void when sintering temperature and addition of AR glass were increased, which correspond well to phase identification analysis.

  1. Interfacial characterization of ceramic core materials with veneering porcelain for all-ceramic bi-layered restorative systems.

    PubMed

    Tagmatarchis, Alexander; Tripodakis, Aris-Petros; Filippatos, Gerasimos; Zinelis, Spiros; Eliades, George

    2014-01-01

    The aim of the study was to characterize the elemental distribution at the interface between all-ceramic core and veneering porcelain materials. Three groups of all-ceramic cores were selected: A) Glass-ceramics (Cergo, IPS Empress, IPS Empress 2, e-max Press, Finesse); B) Glass-infiltrated ceramics (Celay Alumina, Celay Zirconia) and C) Densely sintered ceramics (Cercon, Procera Alumina, ZirCAD, Noritake Zirconia). The cores were combined with compatible veneering porcelains and three flat square test specimens were produced for each system. The core-veneer interfaces were examined by scanning electron microscopy and energy dispersive x-ray microanalysis. The glass-ceramic systems showed interfacial zones reach in Si and O, with the presence of K, Ca, Al in core and Ca, Ce, Na, Mg or Al in veneer material, depending on the system tested. IPS Empress and IPS Empress 2 demonstrated distinct transitional phases at the core-veneer interface. In the glassinfiltrated systems, intermixing of core (Ce, La) with veneer (Na, Si) elements occurred, whereas an abrupt drop of the core-veneer elemental concentration was documented at the interfaces of all densely sintered ceramics. The results of the study provided no evidence of elemental interdiffusion at the core-veneer interfaces in densely sintered ceramics, which implies lack of primary chemical bonding. For the glass-containing systems (glassceramics and glass-infiltrated ceramics) interdiffusion of the glass-phase seems to play a critical role in establishing a primary bonding condition between ceramic core and veneering porcelain.

  2. Long-term Bond Strength between Layering Indirect Composite Material and Zirconia Coated with Silicabased Ceramics.

    PubMed

    Fushiki, Ryosuke; Komine, Futoshi; Honda, Junichi; Kamio, Shingo; Blatz, Markus B; Matsumura, Hideo

    2015-06-01

    This study evaluated the long-term shear bond strength between an indirect composite material and a zirconia framework coated with silica-based ceramics, taking the effect of different primers into account. A total of 165 airborne-particle abraded zirconia disks were subjected to one of three pretreatments: no pretreatment (ZR-AB), airborne-particle abrasion of zirconia coated with feldspathic porcelain (ZR-PO-AB), and 9.5% hydrofluoric acid etching of zirconia coated with feldspathic porcelain (ZR-PO-HF). An indirect composite material (Estenia C&B) was then bonded to the zirconia disks after they were treated with one of the following primers: Clearfil Photo Bond (CPB), Clearfil Photo Bond with Clearfil Porcelain Bond Activator (CPB + Activator), Estenia Opaque Primer (EOP), Porcelain Liner M Liquid B (PLB), or no priming (CON, control group). Shear bond strength was tested after 100,000 thermocycles, and the data were analyzed using the Steel-Dwass U-test (α = 0.05). For ZR-PO-AB and ZR-PO-HF specimens, bond strength was highest in the CPB+Activator group (25.8 MPa and 22.4 MPa, respectively). Bond strengths were significantly lower for ZR-AB specimens in the CON and PLB groups and for ZR-PO-AB specimens in the CON, CPB, and EOP groups. Combined application of a hydrophobic phosphate monomer (MDP) and silane coupling agent enhanced the long-term bond strength of indirect composite material to a zirconia coated with silica-based ceramics.

  3. [The bonding mechanisms of base metals for metal-ceramic crown microstructure analysis of bonding agent and gold bond between porcelain and base metals].

    PubMed

    Wang, C C; Hsu, C S

    1996-06-01

    The use of base metal alloys for porcelain fused to a metal crown and bridges has increased recently because of lower price, high hardness, high tensile strength and high elastic modulus. The addition of beryllium to base metal alloys increased fluidity and improved casting fitness. Beryllium also controlled surface oxidation and bonding strength. The bonding agent and gold bonding agent also affected the bonding strength between porcelain and metal alloys. Four commercially available ceramic base alloys were studied (two alloys contained beryllium element, another two did not). The purpose of this investigation was to study the microstructure between porcelain matrix, bonding agent and alloy matrix interfaces. A scanning electron micro-probe analyzer and energy dispersive X-ray spectroscopy (EDXS) were used to study the distribution of elements (Ni, Cr, Mo, Cu, O, Si, Sn, Al) in four base alloys. The following results were obtained: 1. The thickness of the oxidized layer of Rexillium III alloy and Unitbond alloy (contained beryllium) was thinner than Unibond alloy and Wiron 88 alloy (no beryllium). 2. The thickness of the oxidized layer of alloys in air (10 minutes and 30 minutes) was thinner in Unitbond (2.45 microns and 3.80 microns) and thicker in Wiron 88 (4.39 microns and 5.96 microns). 3. The thickness of the oxidized layer occurring for a duration of ten minutes (in vaccum) showed that the Rexillium III alloy was the thinnest (1.93 microns), and Wiron 88 alloy was the thickest (2.30 microns). But in thirty minutes (vacuum), Unitbond alloy was the thinnest (3.37 microns), and Wiron 88 alloy was the thickest (5.51 microns). 4. The intensity of Cr elements was increased obviously near the interface between Unitbond alloy, Wiron 88 alloy (no beryllium) and oxidized layer, but the intensity of Ni and Mo elements was slightly increased. The intensity of Cr element was not increased markedly between Rexillium III alloy, Unitbond alloy (beryllium) and oxidized layer. 5. A white-grayish oxidized layer appeared at the metal-ceramic interfaces but the thickness of oxidized layer was not obviously different. 6. The use of bonding agent at metal-ceramic interface leads to the deposition of many Sn elements at about 40 microns range within the porcelain surface. 7. Second interaction phases at the porcelain layer appeared when gold bonding agent was used, and a 50-100 microns microleakage occurred at the metal-ceramic interface.

  4. Porcelain enamel passive thermal control coatings

    NASA Technical Reports Server (NTRS)

    Leggett, H.; King, H. M.

    1978-01-01

    This paper discusses the development and evaluation of a highly adherent, low solar absorptance, porcelain enamel thermal control coating applied to 6061 and 1100 aluminum for space vehicle use. The coating consists of a low index of refraction, transparent host frit and a high volume fraction of titania as rutile, crystallized in-situ, as the scattering medium. Solar absorptance is 0.21 at a coating thickness of 0.013 cm. Hemispherical emittance is 0.88. The change in solar absorptance is 0.03, as measured in-situ, after an exposure of 1000 equivalent sun hours in vacuum.

  5. Archaeological Survey of 73 Artillery Firing Points: Fort Bragg Training Area, Cumberland and Hoke Counties, North Carolina

    DTIC Science & Technology

    2006-03-01

    Figure 25. Undecorated and decorated rim sherds from 3 1HK695 52 Figure 26. Decorated porcelain cup sherds from 3 1HK695 52 Figure 27. Decorated...pressed-glass sherd and medicine/bitters bottle neck from 3 1HK695 52 Figure 28. Bisque-fired porcelain doll sherd and Prosser type buttons from 3 1HK695...quartz that varies in quality, color and crystalline structure. A single bipolar core fragment of crystal "smoky" quartz was found on the surface in

  6. Surface Water Investigations in Afghanistan: A Summary of Activities from 1952 to 1969. Appendix 14: Hydrology Training Manual Number 1: Basic Streamaging

    DTIC Science & Technology

    1966-01-01

    insulated core is covered by 33 galvanized wires, of which the inner 15 are wrapped in one direction and the outer 18 are wrapped in the reverse...foot marks with Porcelain Enamel Iron Figure Plates. Figure 2•—Non-recording staff gages • Shelters should be well ventilated, especially in...vertical staff gage usually consists of porcelain -enameled iron sections. The sections are usually screwed to a board which is fastened to a suitable

  7. Evaluation of a conditioning method to improve core-veneer bond strength of zirconia restorations.

    PubMed

    Teng, Jili; Wang, Hang; Liao, Yunmao; Liang, Xing

    2012-06-01

    The high strength and fracture toughness of zirconia have supported its extensive application in esthetic dentistry. However, the fracturing of veneering porcelains remains one of the primary causes of failure. The purpose of this study was to evaluate, with shear bond strength testing, the effect of a simple and novel surface conditioning method on the core-veneer bond strength of a zirconia ceramic system. The shear bond strength of a zirconia core ceramic to the corresponding veneering porcelain was tested by the Schmitz-Schulmeyer method. Thirty zirconia core specimens (10 × 5 × 5 mm) were layered with a veneering porcelain (5 × 3 × 3 mm). Three different surface conditioning methods were evaluated: polishing with up to 1200 grit silicon carbide paper under water cooling, airborne-particle abrasion with 110 μm alumina particles, and modification with zirconia powder coating before sintering. A metal ceramic system was used as a control group. All specimens were subjected to shear force in a universal testing machine at a crosshead speed of 0.5 mm/min. The shear bond strength values were analyzed with 1-way ANOVA and Tukey's post hoc pairwise comparisons (α=.05). The fractured specimens were examined with a scanning electron microscope to observe the failure mode. The mean (SD) shear bond strength values in MPa were 47.02 (6.4) for modified zirconia, 36.66 (8.6) for polished zirconia, 39.14 (6.5) for airborne-particle-abraded zirconia, and 46.12 (7.1) for the control group. The mean bond strength of the control (P=.028) and modified zirconia groups (P=.014) was significantly higher than that of the polished zirconia group. The airborne-particle-abraded group was not significantly different from any other group. Scanning electron microscopy evaluation showed that cohesive fracture in the veneering porcelain was the predominant failure mode of modified zirconia, while the other groups principally fractured at the interface. Modifying the zirconia surface with powder coating could significantly increase the shear bond strength of zirconia to veneering porcelain. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  8. Effect of grinding and fluoride-gel exposure on strength of ion-exchanged porcelain.

    PubMed

    Anusavice, K J; Hojjatie, B; Chang, T C

    1994-08-01

    Strengthening of dental porcelain through a diffusion heat treatment at 450 degrees C of a potassium-enriched, ion-exchange surface coating has been demonstrated in several recent studies. However, little attention has been focused on the potential strength reduction of these materials when the treated surfaces are ground or etched under clinically simulated conditions. The objective of this study was to test the hypothesis that partial removal of the surface layers of ion-exchanged porcelains by grinding or exposure to acidulated fluoride gel will significantly reduce their flexure strength. Nine groups of body porcelain disks were ion-exchanged at 450 degrees C for 30 min. One of these groups was subjected to ion exchange and no further surface treatment. Eight specimen groups were subjected to the following procedures after ion exchange: grinding to depths of 50 microns, 100 microns, 150 microns, 200 microns, and 250 microns, and exposure to acidulated fluoride for 30 min, 60 min, and 300 min. A tenth group (FC) was fired at 960 degrees C and fast-cooled in air, but the disks were not subjected to the ion-exchange treatment. Surface stress was calculated from measured values of cracks induced in the treated surfaces. Fluoride exposure for up to 60 min resulted in a significant decrease in surface compression (P < or = 0.05), although this treatment had no effect on strength. Grinding to a depth of from 100 microns to 250 microns caused a significant decrease in strength, while removal of a 50-microns layer caused no significant change (P > 0.05).

  9. Relation Between Roughness of Interface and Adherence of Porcelain Enamel to Steel

    NASA Technical Reports Server (NTRS)

    Richmond, J C; Moore, D G; Kirkpatrick, H B; Harrison, W N

    1954-01-01

    Porcelain-enamel ground coats were prepared and applied under conditions that gave various degrees of adherence between enamel and a low-carbon steel (enameling iron). The variations in adherence were produced by (a) varying the amount of cobalt-oxide addition in the frit, (b) varying the type of metallic-oxide addition in the frit, keeping the amount constant at 0.8 weight percent, (c) varying the surface treatment of the metal before application of the enamel, by pickling, sandblasting, and polishing, and (d) varying the time of firing of the enamel containing 0.8 percent of cobalt oxide. Specimens of each enamel were given the standard adherence test of the Porcelain Enamel Institute. Metallographic sections were made on which the roughness of interface was evaluated by counting the number of anchor points (undercuts) per centimeter of specimen length and also by measuring the length of the interface and expressing results as the ratio of this length to the length of a straight line parallel to the over-all direction of the interface.

  10. The effect of bleaching agents on the microhardness of dental aesthetic restorative materials.

    PubMed

    Türker, S B; Biskin, T

    2002-07-01

    This study investigated the effects of three home bleaching agents on the microhardness of various dental aesthetic restorative materials. The restorative materials were: feldspatic porcelain, microfilled composite resin and light-cured modified glass-ionomer cement and the bleaching agents Nite-White (16% carbamide peroxide), Opalescence (10% carbamide peroxide and carbapol jel) and Rembrandt (10% carbamide peroxide jel). A total of 90 restorative material samples were prepared 1 cm diameter and 6 mm thick and kept in distilled water for 24 h before commencing bleaching which was carried out for 8 h day-1 for 4 weeks. Microhardness measurements were then made using a Tukon tester. Statistically significant differences with respect to unbleached controls were found only for the feldspatic porcelain and microfilled composite resins (P <0.05) for Nite-White and Opalescence. All the bleaching agents decreased the microhardness of the porcelain and increased that of the light cured modified glass-ionomer cement. For the composite resin, whereas Nite-White increased its microhardness, the other bleaching agents decreased it. There were no significant differences between the bleaching agents for any of the restorative materials.

  11. High temperature characteristics and solidification microstructures of dental metallic materials. Part III alloys for metal-bond porcelain.

    PubMed

    Nagasawa, Sakae; Yoshida, Takamitsu; Terashima, Nobuyoshi; Mizoguchi, Toshihide; Yagasaki, Hiroshi; Kamijo, Koichiro; Ito, Michio; Platt, Jeffrey A; Oshida, Yoshiki

    2005-03-01

    The thermal expansion rate, coefficient of thermal expansion, and high temperature strength of two types of commercially available alloy for metal-bond porcelain, KIK-HII (KIK) and Degubond-J2 (J2), were evaluated up to the liquidus point temperature using a thermo-mechanical analyzer. Furthermore, microstructure in the solid-liquid coexisting region was observed for evaluation. Our results revealed the following findings: 1. For KIK, solidus point was 1,209.3 +/- 3.2 degrees C, liquidus point was 1,308.3 +/- 7.10 degrees C, and melting expansion rate was 0.41+/- 0.16%. 2. For J2, solidus point was 1,198.3 +/- 0.6 degrees C, liquidus point was 1,253.0 +/- 4.4 degrees C, and melting expansion rate was 4.50 +/- 0.80%. 3. At high temperature, the mechanical characteristics of KIK greatly differed from those of J2. The risk of causing deformation during porcelain baking was suggested for KIK. Removal of segregation during casting was considered difficult in J2.

  12. Effect of Different Ceramic Crown Preparations on Tooth Structure Loss: An In Vitro Study

    NASA Astrophysics Data System (ADS)

    Ebrahimpour, Ashkan

    Objective: To quantify and compare the amount of tooth-structure reduction following the full-coverage preparations for crown materials of porcelain-fused-to-metal, lithium disilicate glass-ceramic and yttria-stabilized tetragonal zirconia polycrystalline for three tooth morphologies. Methods: Groups of resin teeth of different morphologies were individually weighed to high precision, then prepared following the preparation guidelines. The teeth were re-weighed after preparation and the amount of structural reduction was calculated. Statistical analyses were performed to find out if there was a significant difference among the groups. Results: Amount of tooth reduction for zirconia crown preparations was the lowest and statistically different compared with the other two materials. No statistical significance was found between the amount of reduction for porcelain-fused-to-metal and lithium disilicate glass-ceramic crowns. Conclusion: Within the limitations of this study, more tooth structure can be saved when utilizing zirconia full-coverage restorations compared with lithium disilicate glass-ceramic and porcelain-fused-to-metal crowns in maxillary central incisors, first premolars and first molars.

  13. The perceval S aortic valve implantation in patients with porcelain aorta; is this ideal option?

    PubMed

    Baikoussis, Nikolaos G; Dedeilias, Panagiotis; Prappa, Efstathia; Argiriou, Michalis

    2017-01-01

    We would like to present in this paper a patient with severe aortic valve stenosis referred to our department for surgical aortic valve replacement. In this patient, it was intraoperatively detected an unexpected heavily calcified porcelain ascending aorta. We present the treatment options in this situation, the difficulties affronted intraoperatively, the significance of the preoperative chest computed tomography scan and the use of the Perceval S aortic valve as ideal bioprosthesis implantation. This is a self-expanding, self-anchoring, and sutureless valve with a wide indication in all patients requiring aortic bioprosthesis.

  14. Precision technique for trimming dies using a magnification device.

    PubMed

    Beck, D B

    1980-05-01

    This article described a technique for trimming a die under magnification. However, the microscope is also useful for checking (1) margins of wax patterns for completeness, (2) the internal surfaces of castings for imperfections, bubbles, or retained investment particles which could prevent proper seating of the castings on the dies, (3) for cracks or contamination in dental porcelain as well as porcelain flash on margins; and (4) precision attachment operation after casting or soldering procedures. Attention to detail in these laboratory procedures greatly improves the final fit of dental castings and saves subsequent chairside adjustments and remakes.

  15. Combining monolithic zirconia crowns, digital impressioning, and regenerative cement for a predictable restorative alternative to PFM.

    PubMed

    Griffin, Jack D

    2013-03-01

    Advances in indirect esthetic materials in recent years have provided the dental profession higher levels of strength and esthetics than ever before with products like lithium disilicate and zirconium oxide. Providing excellent fit and versatile performance, and because there is no porcelain to delaminate, chip, or fracture, monolithic zirconia crowns have the potential to outperform other layered restorations such as porcelain-fused-to-metal (PFM). This review of monolithic zirconia highlights a clinical case in which all-zirconia restorations were combined with CAD/CAM technology for a successful esthetic restorative outcome.

  16. The effect of core material, veneering porcelain, and fabrication technique on the biaxial flexural strength and weibull analysis of selected dental ceramics.

    PubMed

    Lin, Wei-Shao; Ercoli, Carlo; Feng, Changyong; Morton, Dean

    2012-07-01

    The objective of this study was to compare the effect of veneering porcelain (monolithic or bilayer specimens) and core fabrication technique (heat-pressed or CAD/CAM) on the biaxial flexural strength and Weibull modulus of leucite-reinforced and lithium-disilicate glass ceramics. In addition, the effect of veneering technique (heat-pressed or powder/liquid layering) for zirconia ceramics on the biaxial flexural strength and Weibull modulus was studied. Five ceramic core materials (IPS Empress Esthetic, IPS Empress CAD, IPS e.max Press, IPS e.max CAD, IPS e.max ZirCAD) and three corresponding veneering porcelains (IPS Empress Esthetic Veneer, IPS e.max Ceram, IPS e.max ZirPress) were selected for this study. Each core material group contained three subgroups based on the core material thickness and the presence of corresponding veneering porcelain as follows: 1.5 mm core material only (subgroup 1.5C), 0.8 mm core material only (subgroup 0.8C), and 1.5 mm core/veneer group: 0.8 mm core with 0.7 mm corresponding veneering porcelain with a powder/liquid layering technique (subgroup 0.8C-0.7VL). The ZirCAD group had one additional 1.5 mm core/veneer subgroup with 0.7 mm heat-pressed veneering porcelain (subgroup 0.8C-0.7VP). The biaxial flexural strengths were compared for each subgroup (n = 10) according to ISO standard 6872:2008 with ANOVA and Tukey's post hoc multiple comparison test (p≤ 0.05). The reliability of strength was analyzed with the Weibull distribution. For all core materials, the 1.5 mm core/veneer subgroups (0.8C-0.7VL, 0.8C-0.7VP) had significantly lower mean biaxial flexural strengths (p < 0.0001) than the other two subgroups (subgroups 1.5C and 0.8C). For the ZirCAD group, the 0.8C-0.7VL subgroup had significantly lower flexural strength (p= 0.004) than subgroup 0.8C-0.7VP. Nonetheless, both veneered ZirCAD groups showed greater flexural strength than the monolithic Empress and e.max groups, regardless of core thickness and fabrication techniques. Comparing fabrication techniques, Empress Esthetic/CAD, e.max Press/CAD had similar biaxial flexural strength (p= 0.28 for Empress pair; p= 0.87 for e.max pair); however, e.max CAD/Press groups had significantly higher flexural strength (p < 0.0001) than Empress Esthetic/CAD groups. Monolithic core specimens presented with higher Weibull modulus with all selected core materials. For the ZirCAD group, although the bilayer 0.8C-0.7VL subgroup exhibited significantly lower flexural strength, it had highest Weibull modulus than the 0.8C-0.7VP subgroup. The present study suggests that veneering porcelain onto a ceramic core material diminishes the flexural strength and the reliability of the bilayer specimens. Leucite-reinforced glass-ceramic cores have lower flexural strength than lithium-disilicate ones, while fabrication techniques (heat-pressed or CAD/CAM) and specimen thicknesses do not affect the flexural strength of all glass ceramics. Compared with the heat-pressed veneering technique, the powder/liquid veneering technique exhibited lower flexural strength but increased reliability with a higher Weibull modulus for zirconia bilayer specimens. Zirconia-veneered ceramics exhibited greater flexural strength than monolithic leucite-reinforced and lithium-disilicate ceramics regardless of zirconia veneering techniques (heat-pressed or powder/liquid technique). © 2012 by the American College of Prosthodontists.

  17. Elemental analyses on porcelains of Tang and Song Dynasties excavated from Yongjinwan zone at Jinsha site

    NASA Astrophysics Data System (ADS)

    Xia, C. D.; Ge, L. J.; Liu, M. T.; Zhu, J. J.; An, Z.; Bai, B.

    2018-02-01

    The work presented here carried out elemental analyses on 60 porcelain shards of Tang and Song Dynasties, unearthed from Yongjinwan zone at Jinsha site, Sichuan, China, using a combination of PIXE and RBS methods. Six shards from Liulichang kiln site and 6 from Shifangtang kiln site were also analyzed as reference materials. The factor analyses for the elemental compositions in the bodies and glazes of the total 72 porcelain shards have been performed to explore their similarities and differences. Combining the results of factor analyses on elements in bodies and glazes and the classification by traditional archaeological criteria, the provenances for most of shards unearthed from Yongjinwan zone in Jinsha site could be determined. Majority of shards with a Qiong-kiln style were found as products of Liulichang kiln, this is consistent with Yongjinwan's geographical location and social environment, i.e., Yongjinwan was a suburban settlement nearest to Liulichang kiln in ancient times. Although both products of Liulichang kiln and Shifangtang kiln belonged to Qiong-kiln system and they shared a similar appearance such as red body and celadon glaze, there were distinct differences in chemical composition which could be unraveled by PIXE-RBS measurements and factor analysis. There were no apparent differences of chemical compositions for the same kinds of body and glaze between Tang and Song Dynasties, which may suggest that raw materials and production techniques for the same kinds of body and glaze continued between Tang and Song Dynasties. The chemical characteristics for each kind of body and glaze and the correlations between element composition and porcelain appearance were also obtained in this work.

  18. Effect of water storage on the silanization in porcelain repair strength.

    PubMed

    Berry, T; Barghi, N; Chung, K

    1999-06-01

    This study examined the long-term water storage affect of silanization on shear bond strength of composite resin to porcelain. One hundred and sixty square-shaped specimens were fabricated and sanded flat sequentially with silicone carbide papers. The specimens were then placed into four groups and 16 subgroups of 10 specimens each randomly. Four commercially available silane systems, two one-mix and two two-mix, were tested in this study. Teflon tubes with an internal diameter of 2.97 mm and 2 mm in height were filled with a dual cure composite resin (Mirage FLC), placed on the silanated surfaces and light-cured for 120 s. Specimens were stored in room temperature water and subjected to shear bond strength testing after 24 h, 1 week, 1 month and 3 month periods of immersion. An Instron Universal testing machine with a crosshead speed of 0.5 mm/min was used for the testing. The mean values of the shear bond strengths ranged from 4.38 MPa (24-h period) to 23.90 MPa (3-month period). ANOVA and Scheffe' tests were used to analyse data with confidence level at 95%. All groups recorded an increase in bond strength after one week as compared with the 24-h period (P<0.05). With the exception of a one-mix system, all systems showed significantly higher bond strength at 3 weeks as compared with the 24-h and 1-week water storage periods. In conclusion, bond strength of composite resin to porcelain resulting from silanization of porcelain increased during the experimental period. The bond strength also varied for different silanes used in this study.

  19. Chemical Stability of Bioglass in Simulated Oral Environment.

    PubMed

    Sm, Moazzami; R, Sadid Zadeh; K, Kianoush; M, Sarmad; F, Barani Karbaski; R, Amiri Daluyi; Rb, Kazemi

    2016-09-01

    Bioglasses are a series of biocompatible dental materials, which are considered as light conducting inserts in resin composite restorations. Consequently, their chemical stability is more essential when they are used in conjunction with resin composite. The aim of this study was to evaluate and compare the chemical stability of Bioglass with dental porcelain and resin composite by determining the amount of released K+, Na+, Ca2+ ions and silicone elements from these materials as a result of exposure to tested solutions with different pH levels including: Sodium Bicarbonate [SB, (pH=9.2)], Sodium Buffer Lactate [SBL, (pH=2.4)], Acetic Acid [AA, (pH=2.4)], and Distilled Water [DW, (pH=6.2)]. In this experimental study, forty 2.0 × 4.0 cylindrical rods for each tested material group (Dental porcelain, Resin composite and Bioglass) were prepared. They were divided into four subgroups of 10 rods each, which immersed in one of the four testing solutions in a designated container. The containers were stored at 50°C and 100% humidity for one week. The released ions were measured by using a spectrophotometer (µg/cm 2 /ml). The data were statistically analyzed by nonparametric Kruskal-Wallis H test. It was observed that the tested materials released ions at different levels of concentration. The significant amounts of Sodium, Calcium, and Silicon ions release were measured in Bioglass subgroups in all the tested solutions ( p < 0.001). Potassium ion release from dental porcelain was the largest in all solutions except for AA in which Bioglass had the greatest potassium ion release ( p < 0.001). A greater structural instability was observed for Biogalss group than dental porcelain and resin composite in testing solutions with different pH levels.

  20. Post-fatigue fracture resistance of metal core crowns: press-on metal ceramic versus a conventional veneering system

    PubMed Central

    Agustín-Panadero, Rubén; Campos-Estellés, Carlos; Labaig-Rueda, Carlos

    2015-01-01

    Background The aim of this in vitro study was to compare the mechanical failure behavior and to analyze fracture characteristics of metal ceramic crowns with two veneering systems – press-on metal (PoM) ceramic versus a conventional veneering system – subjected to static compressive loading. Material and Methods Forty-six crowns were constructed and divided into two groups according to porcelain veneer manufacture. Group A: 23 metal copings with porcelain IPS-InLine veneering (conventional metal ceramic). Group B: 23 metal copings with IPS-InLine PoM veneering porcelain. After 120,000 fatigue cycles, the crowns were axially loaded to the moment of fracture with a universal testing machine. The fractured specimens were examined under optical stereomicroscopy and scanning electron microscope. Results Fracture resistance values showed statistically significant differences (Student’s t-test) regarding the type of ceramic veneering technique (p=0.001): Group A (conventional metal ceramics) obtained a mean fracture resistance of 1933.17 N, and Group B 1325.74N (Press-on metal ceramics). The most common type of fracture was adhesive failure (with metal exposure) (p=0.000). Veneer porcelain fractured on the occlusal surface following a radial pattern. Conclusions Metal ceramic crowns made of IPS InLine or IPS InLine PoM ceramics with different laboratory techniques all achieved above-average values for clinical survival in the oral environment according to ISO 6872. Crowns made with IPS InLine by conventional technique resisted fracture an average of 45% more than IPS InLine PoM fabricated with the press-on technique. Key words:Mechanical failure, conventional feldspathic, pressable ceramic, chewing simulator, thermocycling, compressive testing, fracture types, scanning electron microscope. PMID:26155346

  1. [Effect of Al₂O₃ sandblasting on the bond strength between 3mol% yttrium-stabilized tetragonal zirconium polycrystal zirconia framework and veneering porcelain].

    PubMed

    Qiang, Zeng; Ning, Li; Yanan, Zhou; Jiazhen, Yan; Wenbo, Liu

    2015-12-01

    The effect of sandblasting on the bond strength between 3mol% yttrium-stabilized tetragonal zirconium polycrystal (3Y-TZP) zirconia framework and veneering porcelain was evaluated. A total of 21 specimens [(25 ± 1) mm x (3 ± 0.1) mmx (0.5 ± 0.05) mm] were prepared according to ISO 9693. The specimens were then randomly divided into 3 groups. Sandblasting was performed on 2 meshes of Al₂O₃ particles: group A with mesh 110 and group B with mesh 80. Group C, which was not sandblasted, was the control group. The surface roughness of the zirconia framework, as well as the bond strength between 3Y-TZP zirconia framework and veneering porcelain, was measured. The interface microstructure was observed by scanning electron microscope (SEM), and elemental distribution was detected by energy dispersive spectroscopy (EDS). Surface roughness values were (1.272 ± 0.149) μm for group A, (0.622 ± 0.113) μm for group B, and (0.221 ± 0.065) μm for group C. Statistical significance were found among groups (P < 0.05). The bond strength values were (28.21 ± 1.52) MPa for group A, (27.71 ± 1.27) MPa for group B, and (24.87 ± 3.84) MPa for group C. Statistical significance was found between group A and group C (P < 0.05), whereas the other groups had no statistical significance (P > 0.05). Interface adhesion failure was the primary performance. SEM images showed the close interface bonding, and EDS showed that the interface had no obvious element penetration. Al₂O₃ sandblasting can slightly enhance the bond strength between zirconia framework and veneering porcelain.

  2. [Evaluation of the effect of modified wet particle erosion on bond strength between 3Y-TZP zirconia framework and veneering porcelain].

    PubMed

    Guo, Jing; Zhu, Jia; Liu, Hon-Guang; Zhu, Hong-Shui

    2017-02-01

    To evaluate the effect of bond strength between 3mol% yttrium-stabilized tetragonal zirconium polycrystal (3Y-TZP) zirconia framework after modified wet particle erosion and veneering porcelain. A total of 174 [8 mm× 8 mm× 3 mm (±0.02)] specimens were prepared and then randomly divided into different groups according to different particle size, sandblasting pressure, sandblasting time through conventional sandblasting (experimental groups); specimens in the control group were not sandblasted. The bond strength between 3Y-TZP zirconia framework and veneering porcelain was measured using a universal testing machine. Statistical analysis was performed using SPSS17.0 software package. The bond strength of specimens treated by two methods-conventional sandblasting and modified wet particle erosion under the same condition (150 μm, 0.6 MPa, 30 s) were acquired, while the surface was analyzed microscopically before the specimens were veneered with the veneering ceramic under scanning electronic microscope (SEM). The bond strength of conventional sandblasting group under the condition (110 μm, 0.4 MPa,30 s) was maximal, and significantly higher than the control group (P<0.05). The bond strength of modified wet particle erosion group was significantly higher than the conventional sandblasting group and control group (P<0.01); SEM showed that the surface of specimen with modified wet particle erosion was homogeneously rough; the surface specimen with conventional sandblasting was heterogeneously rough, some microcracks were seen in some areas. Sandblasting can slightly enhance the bond strength between 3Y-TZP zirconia framework and veneering porcelain, modified wet particle erosion is recommended for 3Y-TZP zirconia framework surface treatment.

  3. Effect of ion exchange on strength and slow crack growth of a dental porcelain.

    PubMed

    Rosa, Vinicius; Yoshimura, Humberto N; Pinto, Marcelo M; Fredericci, Catia; Cesar, Paulo F

    2009-06-01

    To determine the effect of ion exchange on slow crack growth (SCG) parameters (n, stress corrosion susceptibility coefficient, and sigma(f0), scaling parameter) and Weibull parameters (m, Weibull modulus, and sigma(0), characteristic strength) of a dental porcelain. 160 porcelain discs were fabricated according to manufacturer's instructions, polished through 1 microm and divided into two groups: GC (control) and GI (submitted to an ion exchange procedure using a KNO3 paste at 470 degrees C for 15 min). SCG parameters were determined by biaxial flexural strength test in artificial saliva at 37 degrees C using five constant stress rates (n=10). 20 specimens of each group were tested at 1 MPa/s to determine Weibull parameters. The SPT diagram was constructed using the least-squares fit of the strength data versus probability of failure. Mean values of m and sigma(0) (95% confidence interval), n and sigma(f0) (standard deviation) were, respectively: 13.8 (10.1-18.8) and 60.4 (58.5-62.2), 24.1 (2.5) and 58.1 (0.01) for GC and 7.4 (5.3-10.0) and 136.8 (129.1-144.7), 36.7 (7.3) and 127.9 (0.01) for GI. Fracture stresses (MPa) calculated using the SPT diagram for lifetimes of 1 day, 1 year and 10 years (at a 5% failure probability) were, respectively, 31.8, 24.9 and 22.7 for GC and 71.2, 60.6 and 56.9 for GI. For the porcelain tested, the ion exchange process improved strength and resistance to SCG, however, the material's reliability decreased. The predicted fracture stress at 5% failure probability for a lifetime of 10 years was also higher for the ion treated group.

  4. Failure probability of three designs of zirconia crowns

    PubMed Central

    Ramos, G. Freitas; Monteiro, E. Barbosa Carmona; Bottino, M.A.; Zhang, Y.; de Melo, R. Marques

    2015-01-01

    Objectives This study utilized a 2-parameter Weibull analysis for evaluation of lifetime of fully or partially porcelain-/glaze-veneered zirconia crowns after fatigue test. Methods Sixty first molars were selected and prepared for full-coverage crowns with three different designs(n = 20): Traditional –crowns with zirconia framework covered with feldspathic porcelain; Modified– crowns partially covered with veneering porcelain; and Monolithic–full-contour zirconia crowns. All specimens were treated with a glaze layer. Specimens were subjected to mechanical cycling (100N, 3Hz) with a piston with hemispherical tip (Ø=6 mm) until the specimens failed or up to 2×106 cycles. Every 500,000 cycles intervals, the fatigue tests were interrupted, and stereomicroscopy (10 X) was used to inspect the specimens for damage. We performed Weibull analysis of interval data to calculate the number of failures in each interval. Results The types and number of failures according to the groups were: cracking (Traditional-13, Modified-6) and chipping (Traditional-4) of the feldspathic porcelain, followed by delamination (Traditional-1) at the veneer/core interface and debonding (Monollithic-2) at the cementation interface. Weibull parameters (beta, scale; and eta, shape), with a two-sided confidence interval of 95%, were: Traditional – 1.25 and 0.9 × 106cycles; Modified– 0.58 and 11.7 × 106 cycles; and Monolithic – 1.05 and 16.5 × 106 cycles. Traditional crowns showed greater susceptibility to fatigue, the Modified group presented higher propensity to early failures, and the Monolithic group showed no susceptibility to fatigue. The Modified and Monolithic groups presented the highest number of crowns with no failures after the fatigue test. Conclusions The three crown designs presented significantly different behaviors under fatigue. The Modified and the Monolithic groups presented less probability to failure after 2×106cycles. PMID:26509988

  5. Effect of laser heat treatment on Pull-out bond strength of fiber posts treated with different silanes.

    PubMed

    Shafiei, Fereshteh; Saadat, Maryam; Jowkar, Zahra

    2018-05-01

    This study evaluated the effect of three different silanes and post-silanization treatments on the retentive strength of fiber posts luted with an etch-and-rinse resin cement. One hundred intact maxillary central incisors were randomly divided into 10 groups after endodontic treatment and post space preparation (n=10). The fiber posts were etched using 24% hydrogen peroxide. Posts of the control group did not receive silane. In nine experimental groups, each of the three silanes used, Scotchbond Universal adhesive, Bis-Silane and Porcelain Primer, was subjected to three treatments: air-drying at 25°C, warm air-drying and CO2 laser heat treatment. After cementation of the treated posts using One-Step Plus/Duo-Link cement, the specimens were stored for one weak and then subjected to pull-out bond strength (PBS) testing. The data in Newton (N) were analyzed using two-way ANOVA and Tukey tests (α=0.05). PBS was significantly affected by silane type and post-silanization treatment ( p <0.001). The interaction of the two factors was not statistically significant ( p =0.15). The effect of Porcelain Primer on PBS was significantly higher than those of universal adhesive ( p <0.001) and Bis-Silane ( p =0.01), with similar results for the two latter. Warm air-drying and laser treatment significantly increased PBS ( p <0.001). The lowest and highest PBS was obtained in the control (no silane) group (190.9±31) and laser-treated/ Porcelain Primer group (377.1±50), respectively. Warm air-drying and CO2 laser heat treatment had a significantly beneficial effect on retentive strength of fiber posts. Porcelain Primer was significantly more effective than universal adhesive and Bis-Silane. Key words: Laser heat treatment, Pull-out bond strength, fiber post.

  6. Effect of ceramic infrastructure on the failure behavior and stress distribution of fixed partial dentures.

    PubMed

    Borba, Márcia; Duan, Yuanyuan; Griggs, Jason A; Cesar, Paulo F; Della Bona, Álvaro

    2015-04-01

    The effect of the ceramic infrastructure (IS) on the failure behavior and stress distribution of fixed partial dentures (FPDs) was evaluated. Twenty FPDs with a connector cross-section of 16 mm(2) were produced for each IS and veneered with porcelain: (YZ) Vita In-Ceram YZ/Vita VM9 porcelain; (IZ) Vita In-Ceram Zirconia/Vita VM7 porcelain; (AL) Vita In-Ceram AL/Vita VM7 porcelain. Two experimental conditions were evaluated (n = 10). For control specimens, load was applied in the center of the pontic at 0.5 mm/min until failure, using a universal testing machine, in 37°C deionized water. For mechanical cycling (MC) specimens, FPDs were subjected to MC (2 Hz, 140 N, 10(6) cycles) and subsequently tested as described for the control group. For YZ, an extra group of 10 FPDs were built with a connector cross-section of 9 mm(2) and tested until failure. Fractography and FEA were performed. Data were analyzed by ANOVA and Tukey's test (α = 0.05). YZ16 showed the greatest fracture load mean value, followed by YZ16-MC. Specimens from groups YZ9, IZ16, IZ16-MC, AL16 and AL16-MC showed no significant difference for the fracture load. The failure behavior and stress distribution of FPDs was influenced by the type of IS. AL and IZ FPDs showed similar fracture load values but different failure modes and stress distribution. YZ showed the best mechanical behavior and may be considered the material of choice to produce posterior FPDs as it was possible to obtain a good mechanical performance even with a smaller connector dimension (9 mm(2)). Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  7. XRD and SEM study of alumina silicate porcelain insulator

    NASA Astrophysics Data System (ADS)

    Duddi, Dharmender; Singh, G. P.; Kalra, Swati; Shekhawat, M. S.; Tak, S. K.

    2018-05-01

    Higher strength electrical porcelain is a requirement of industry. This will be achieved by a specific composition of raw materials, which is consisted of clays and feldspars. Water absorption, particle size and insulating properties are of special interest now a day. China clay, Ball clay and Quartz are widely used by ceramic industries in Bikaner district of Rajasthan. Sample for present study were prepared by mixing of above clay, feldspar with MnO2, then shrinkage is observed. Bar shaped samples were prepared and heated up to a temperature of about 1185° C to observe shrinkage. For phase study of XRD and SEM are observed.

  8. Three-unit bridge construction in anterior single-pontic areas using a metal-free restorative.

    PubMed

    Narcisi, E M

    1999-02-01

    A new glass-ceramic material, IPS Empress 2, is revolutionizing esthetic restorative dentistry by allowing metal-free, three-unit bridge construction in anterior and premolar single-pontic areas. The case discussed in this article illustrates the material's application in the dual-arch restoration of a young woman with congenitally missing teeth. The material was used as an alternative to single-tooth implant restorations to place two maxillary three-unit bridges, one mandibular three-unit bridge, and two mandibular porcelain veneers. IPS Empress 2 provides an esthetic alternative to porcelain-fused-to-metal restorations by facilitating attractive, functional tooth restoration.

  9. Advances in dental veneers: materials, applications, and techniques

    PubMed Central

    Pini, Núbia Pavesi; Aguiar, Flávio Henrique Baggio; Lima, Débora Alves Nunes Leite; Lovadino, José Roberto; Terada, Raquel Sano Suga; Pascotto, Renata Corrêa

    2012-01-01

    Laminate veneers are a conservative treatment of unaesthetic anterior teeth. The continued development of dental ceramics offers clinicians many options for creating highly aesthetic and functional porcelain veneers. This evolution of materials, ceramics, and adhesive systems permits improvement of the aesthetic of the smile and the self-esteem of the patient. Clinicians should understand the latest ceramic materials in order to be able to recommend them and their applications and techniques, and to ensure the success of the clinical case. The current literature was reviewed to search for the most important parameters determining the long-term success, correct application, and clinical limitations of porcelain veneers. PMID:23674920

  10. Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns.

    PubMed

    Kwon, Taek-Ka; Pak, Hyun-Soon; Yang, Jae-Ho; Han, Jung-Suk; Lee, Jai-Bong; Kim, Sung-Hun; Yeo, In-Sung

    2013-05-01

    All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. THE MEAN FRACTURE STRENGTHS WERE AS FOLLOWS: 54.9 ± 15.6 N for the Lava CAD/CAM zirconia crowns and 87.0 ± 16.0 N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain.

  11. Failure analysis of ceramic clinical cases using qualitative fractography.

    PubMed

    Scherrer, Susanne S; Quinn, Janet B; Quinn, George D; Kelly, J Robert

    2006-01-01

    To educate dental academic staff and clinicians on the application of descriptive (qualitative) fractography for analyses of clinical and laboratory failures of brittle materials such as glass and ceramic. The fracture surface topography of failed glass, glass fiber-reinforced composite, and ceramic restorations (Procera, Cerestore, In-Ceram, porcelain-fused-to-metal) was examined utilizing a scanning electron microscope. Replicas and original failed parts were scrutinized for classic fractographic features such as hackle, wake hackle, twist hackle, arrest lines, and mirrors. Failed surfaces of the veneering porcelain of ceramic and porcelain-fused-to-metal crowns exhibited hackle, wake hackle, twist hackle, arrest lines, and compression curl, which were produced by the interaction of the advancing crack with the microstructure of the material. Fracture surfaces of glass and glass fiber-reinforced composite showed additional features, such as velocity hackle and mirrors. The observed features were good indicators of the local direction of crack propagation and were used to trace the crack back to an initial starting area (the origin). Examples of failure analysis in this study are intended to guide the researcher in using qualitative (descriptive) fractography as a tool for understanding the failure process in brittle restorative materials and also for assessing possible design inadequacies.

  12. [Effect of core: dentin thickness ratio on the flexure strength of IPS Empress II heat-pressed all-ceramic restorative material].

    PubMed

    Liu, Yi-hong; Feng, Hai-lan; Bao, Yi-wang; Qiu, Yan

    2007-02-18

    To evaluate the effect of core:dentin thickness ratio on the flexure strength, fracture mode and origin of bilayered IPS Empress II ceramic composite specimens. IPS Empress II core ceramic, dentin porcelain and bilayered composite specimens with core:dentin thickness ratio of 2:1 and 1:1 were tested in three-point flexure strength. Mean strengths and standard deviations were determined. The optical microscopy was employed for identification of the fracture mode and origin. The flexure strength of dentin porcelain was the smallest(62.7 MPa), and the strength of bilayered composite specimens was smaller than single-layered core ceramic(190.2 MPa). The core: dentin ratio did not influence the strength of bilayered composite specimens. The frequency of occurrence of bilayered specimen delaminations was higher in the group of core: dentin thickness ratio of 1:1 than in the group of 2:1. IPS Empress II core ceramic was significantly stronger than veneering dentin porcelain. Core:dentin thickness ratio could significantly influence the fracture mode and origin, and bilayered IPS Empress II ceramic composite specimens showed little influence in the fracture strength.

  13. The effect of heat treatment simulating porcelain firing processes on titanium corrosion resistance.

    PubMed

    Sokołowski, Grzegorz; Rylska, Dorota; Sokołowski, Jerzy

    2016-01-01

    Corrosion resistance of titanium used in metal-ceramic restorations in manufacturing is based on the presence of oxide layer on the metal surface. The procedures used during combining metallic material with porcelain may affect the changes in oxide layers structure, and thus anticorrosive properties of metallic material. The aim of the study was an evaluation of potential changes in the structure and selected corrosion properties of titanium after sandblasting and thermal treatment applicable to the processes of ceramics fusion. Milled titanium elements were subjected to a few variants of the processes typical of ceramics fusion and studied in terms of resistance to electrochemical corrosion. The study included the OCP changes over time, measurements of Icorr, Ecorr and Rp as well as potentiodynamic examinations. Surface microstructure and chemical composition were analyzed using SEM and EDS methods. The results obtained allow us to conclude that the processes corresponding to ceramic oxidation and fusion on titanium in the variants used in the study do not cause deterioration of its anticorrosive properties, and partially enhance the resistance. This depends on the quality of oxide layers structure. Titanium elements treated by porcelain firing processes do not lose their corrosion resistance.

  14. Er:YAG laser debonding of porcelain veneers

    NASA Astrophysics Data System (ADS)

    Buu, Natalie; Morford, Cynthia; Finzen, Frederick; Sharma, Arun; Rechmann, Peter

    2010-02-01

    The removal of porcelain veneers using Er:YAG lasers has not been previously described in the scientific literature. This study was designed to systematically investigate the efficacy of an Er:YAG laser on veneer debonding without damaging the underlying tooth structure, as well as preserving a new or misplaced veneer. Initially, Fourier Transform Infrared Spectroscopy (FTIR) was used on flat porcelain veneer samples (IPS Empress Esthetic; Ivoclar Vivadent, Amherst, NY) to assess which infrared laser wavelengths are transmitted through the veneer. Additionally, FTIR spectra from a veneer bonding cement (RelyX Veneer Cement A1; 3M ESPE, St. Paul, MN) were obtained. While the veneer material showed no characteristic water absorption bands in the FTIR, the bonding cement has a broad H2O/OH absorption band coinciding with the ER:YAG laser emission wavelength. Consequently Er:YAG laser energy transmission through different veneer thicknesses was measured. The porcelain veneers transmitted 11 - 18 % of the incident Er:YAG laser energy depending on their thicknesses (Er:YAG laser: LiteTouch by Syneron; wavelength 2,940 nm, 10 Hz repetition rate, pulse duration 100 μs at 133 mJ/pulse; straight sapphire tip 1,100 μm diameter; Syneron, Yokneam, Israel). Initial signs of cement ablation occurred at approximately 1.8 - 4.0 J/cm2. This can be achieved by irradiating through the veneer with the fiber tip positioned at a distance of 3-6 mm from the veneer surface, and operating the Er:YAG laser with 133 mJ output energy. All eleven veneers bonded on extracted anterior incisor teeth were easily removed using the Er:YAG laser. The removal occurred without damaging underlying tooth structure as verified by light microscopic investigation (Incident Light Microscope Olympus B 50, Micropublisher RTV 3.3 MP, Image Pro software, Olympus). The debonding mainly occurred at the cement/veneer interface. When the samples were stored in saline solution for 5 days and/or an air-waterspray was used during irradiation, there was a high chance that the veneer would fractured during debonding. However if samples were not stored in water and only air spray was used, 75% of the veneers could be removed without any fracture. The use of an Er:YAG laser can be effective in not only debonding porcelain veneers and preserving tooth structure, but also in maintaining veneer integrity.

  15. A comparative analysis of reticular crack on ceramic plate driven by thermal shock

    NASA Astrophysics Data System (ADS)

    Xu, XiangHong; Sheng, ShiLong; Tian, Cheng; Yuan, WenJun

    2016-07-01

    Reticular crack is generally found on the surface of ceramic material that has been subjected to a thermal-shock condition. In the present study, a quantitative effect of thermal shock and quench temperature has been studied and investigated. Experimental tests were carried out to characterize the reticular crack that has been found in the Ge Kiln, which is a famous art of the ancient Chinese culture. After comparative analysis between thermal-shock cracks and the glaze crack patterns of the Ge Kiln porcelain, it is found that this study is expected to provide a powerful tool for recurrence of the long-lost firing and cooling process of the Ge Kiln porcelain.

  16. Toxicity of porcelain-fused-to-metal substrate to zebrafish (Danio rerio) embryos and larvae.

    PubMed

    Zhao, Libo; Si, Jing; Wei, Yuan; Li, Sirui; Jiang, Yanjiao; Zhou, Rong; Liu, Bin; Zhang, Hong

    2018-06-15

    Porcelain-fused-to-metal (PFM) crowns are a standard restoration technique in dentistry, but toxicity of PFM in vivo has not been systematically evaluated. The present study evaluated the effects of various metal alloy shells of PFM crowns on the development of zebrafish embryos and larvae in order to determine the safety of these materials. Gold palladium (Au-Pd), silver palladium (Ag-Pd), Nickel chromium (Ni-Cr), cobalt chromium (Co-Cr), titanium (Ti) alloy porcelain crowns were immersed in artificial saliva for 1, 4, and 7 weeks, and the leach solution was collected and used to treat zebrafish embryos at 4-144 h PFM. Toxicity was assessed based on mortality, spontaneous movement, heart rate, hatchability, malformation, and swimming behavior. The 1-week leachates of the five PFMs were not toxic to zebrafish. The rates of mortality and malformation of zebrafish in the Ni-Cr alloy group were increased whereas spontaneous movement, heart rate, and swimming behavior were decreased for 4- and 7-week leachates. Among metal substrates commonly used in dental work, Ni-Cr alloy was most toxic, followed by Co-Cr and Ag-Pd alloys. Ti and Au-Pd alloys showed good biocompatibility and are therefore the most suitable materials for clinical applications. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns

    PubMed Central

    Kwon, Taek-Ka; Pak, Hyun-Soon; Han, Jung-Suk; Lee, Jai-Bong; Kim, Sung-Hun

    2013-01-01

    PURPOSE All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. MATERIALS AND METHODS Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. RESULTS The mean fracture strengths were as follows: 54.9 ± 15.6 N for the Lava CAD/CAM zirconia crowns and 87.0 ± 16.0 N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. CONCLUSION The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain. PMID:23755332

  18. Identification of proteins interacting with lactate dehydrogenase in claw muscle of the porcelain crab Petrolisthes cinctipes

    PubMed Central

    Cayenne, Andrea P.; Gabert, Beverly; Stillman, Jonathon H.

    2011-01-01

    Biochemical adaptation of enzymes involves conservation of activity, stability and affinity across a wide range of intracellular and environmental conditions. Enzyme adaptation by alteration of primary structure is well known, but the roles of protein-protein interactions in enzyme adaptation are less well understood. Interspecific differences in thermal stability of lactate dehydrogenase (LDH) in porcelain crabs (genus Petrolisthes) are related to intrinsic differences among LDH molecules and by interactions with other stabilizing proteins. Here, we identified proteins that interact with LDH in porcelain crab claw muscle tissue using co-immunoprecipitation, and showed LDH exists in high molecular weight complexes using size exclusion chromatography and Western blot analyses. Co-immunoprecipitated proteins were separated using 2D SDS PAGE and analyzed by LC/ESI using peptide MS/MS. Peptide MS/MS ions were compared to an EST database for Petrolisthes cinctipes to identify proteins. Identified proteins included cytoskeletal elements, glycolytic enzymes, a phosphagen kinase, and the respiratory protein hemocyanin. Our results support the hypothesis that LDH interacts with glycolytic enzymes in a metabolon structured by cytoskeletal elements that may also include the enzyme for transfer of the adenylate charge in glycolytically produced ATP. Those interactions may play specific roles in biochemical adaptation of glycolytic enzymes. PMID:21968246

  19. Porcelain surface conditioning protocols and shear bond strength of orthodontic brackets.

    PubMed

    Lestrade, Ashley M; Ballard, Richard W; Xu, Xiaoming; Yu, Qingzhao; Kee, Edwin L; Armbruster, Paul C

    2016-05-01

    The objective of the present study was to determine which of six bonding protocols yielded a clinically acceptable shear bond strength (SBS) of metal orthodontic brackets to CAD/CAM lithium disilicate porcelain restorations. A secondary aim was to determine which bonding protocol produced the least surface damage at debond. Sixty lithium disilicate samples were fabricated to replicate the facial surface of a mandibular first molar using a CEREC CAD/CAM machine. The samples were split into six test groups, each of which received different mechanical/chemical pretreatment protocols to roughen the porcelain surface prior to bonding a molar orthodontic attachment. Shear bond strength testing was conducted using an Instron machine. The mean, maximum, minimal, and standard deviation SBS values for each sample group including an enamel control were calculated. A t-test was used to evaluate the statistical significance between the groups. No significant differences were found in SBS values, with the exception of surface roughening with a green stone prior to HFA and silane treatment. This protocol yielded slightly higher bond strength which was statistically significant. Chemical treatment alone with HFA/silane yielded SBS values within an acceptable clinical range to withstand forces applied by orthodontic treatment and potentially eliminates the need to mechanically roughen the ceramic surface.

  20. Shear bond strength of porcelain laminate veneers to enamel, dentine and enamel-dentine complex bonded with different adhesive luting systems.

    PubMed

    Öztürk, Elif; Bolay, Şükran; Hickel, Reinhard; Ilie, Nicoleta

    2013-02-01

    The aim of this study was to evaluate the shear bond strength of porcelain laminate veneers to 3 different surfaces by means of enamel, dentine, and enamel-dentine complex. One hundred thirty-five extracted human maxillary central teeth were used, and the teeth were randomly divided into 9 groups (n=15). The teeth were prepared with 3 different levels for bonding surfaces of enamel (E), dentine (D), and enamel-dentine complex (E-D). Porcelain discs (IPS e.max Press, Ivoclar Vivadent) of 2mm in thickness and 4mm in diameter were luted to the tooth surfaces by using 2 light-curing (RelyX Veneer [RV], 3M ESPE; Variolink Veneer [VV], Ivoclar Vivadent) and a dual-curing (Variolink II [V2], Ivoclar Vivadent) adhesive systems according to the manufacturers' instructions. Shear bond strength test was performed in a universal testing machine at 0.5mm/min until bonding failure. Failure modes were determined under a stereomicroscope, and fracture surfaces were evaluated with a scanning electron microscope. The data were statistically analysed (SPSS 17.0) (p=0.05). Group RV-D exhibited the lowest bond strength value (5.42±6.6MPa). There was statistically no difference among RV-D, V2-D (13.78±8.8MPa) and VV-D (13.84±6.2MPa) groups (p>0.05). Group VV-E exhibited the highest bond strength value (24.76±8.8MPa). The type of tooth structure affected the shear bond strength of the porcelain laminate veneers to the 3 different types of tooth structures (enamel, dentine, and enamel-dentine complex). When dentine exposure is necessary during preparation, enough sound enamel must be protected as much as possible to maintain a good bonding; to obtain maximum bond strength, preparation margins should be on sound enamel. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Ceramic materials for porcelain veneers: part II. Effect of material, shade, and thickness on translucency.

    PubMed

    Barizon, Karine T L; Bergeron, Cathia; Vargas, Marcos A; Qian, Fang; Cobb, Deborah S; Gratton, David G; Geraldeli, Saulo

    2014-10-01

    Information regarding the differences in translucency among new ceramic systems is lacking. The purpose of this study was to compare the relative translucency of the different types of ceramic systems indicated for porcelain veneers and to evaluate the effect of shade and thickness on translucency. Disk specimens 13 mm in diameter and 0.7-mm thick were fabricated for the following 9 materials (n=5): VITA VM9, IPS Empress Esthetic, VITA PM9, Vitablocks Mark II, Kavo Everest G-Blank, IPS Empress CAD, IPS e.max CAD, IPS e.maxPress, and Lava Zirconia. VITA VM9 served as the positive control and Lava as the negative control. The disks were fabricated with the shade that corresponds to A1. For IPS e.maxPress, additional disks were made with different shades (BL2, BL4, A1, B1, O1, O2, V1, V2, V3), thickness (0.3 mm), and translucencies (high translucency, low translucency). Color coordinates (CIE L∗ a∗ b∗) were measured with a tristimulus colorimeter. The translucency parameter was calculated from the color difference of the material on a black versus a white background. One-way ANOVA, the post hoc Tukey honestly significant difference, and the Ryan-Einot-Gabriel-Welsch multiple range tests were used to analyze the data (α=.05). Statistically significant differences in the translucency parameter were found among porcelains (P<.001) according to the following rank: VM9>PM9, Empress Esthetic>Empress CAD>Mark II, Everest, e.max CAD>e.max Press>Lava. Significant differences also were noted when different shades and thickness were compared (P<.001). Different ceramic systems designed for porcelain veneers present varying degrees of translucency. The thickness and shade of lithium disilicate ceramic affect its translucency. Shade affects translucency parameter less than thickness. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Digital Smile Design concept delineates the final potential result of crown lengthening and porcelain veneers to correct a gummy smile.

    PubMed

    Trushkowsky, Richard; Arias, David Montalvo; David, Steven

    Prior to initiating any treatment, it is necessary to visualize the desired outcomes. It then becomes possible to formulate the steps required to achieve this result. Digital Smile Design (DSD) utilizes patient input and information gathered through diagnostic procedures to create an esthetic treatment scheme. In the case presented here, the NYUCD Esthetic Evaluation Form, intraoral and extraoral photographs, mounted diagnostic casts, physical examination, and radiographs were the diagnostic modalities. The gathered information served as a starting point for a wax-up and intraoral mock-up. This case report demonstrates how the DSD served as a template for crown lengthening procedures and design of the final porcelain veneer restorations.

  3. Coronary–Coronary Bypass

    PubMed Central

    Erdil, Nevzat; Ates, Sanser; Demirkilic, Ufuk; Tatar, Harun; Sag, Cemal

    2002-01-01

    There is increased risk of systemic embolism during cardiopulmonary bypass in patients with a severely atherosclerotic ascending aorta. We report a coronary–coronary bypass in a 74-year-old man with a porcelain aorta. He underwent a proximal right coronary–distal right coronary artery bypass with a saphenous vein graft, combined with a pedicled arterial graft (left internal mammary artery) to the left anterior descending artery, in the presence of a beating heart without cardiopulmonary bypass. The patient survived without evidence of perioperative myocardial infarction or cerebrovascular accident. One year later, follow-up angiography showed graft patency with good distal runoff. Coronary–coronary bypass on a beating heart without cardiopulmonary bypass can be performed safely in a patient with porcelain aorta. (Tex Heart Inst J 2002;29:54–5) PMID:11995853

  4. Fractographic study of the behavior of different ceramic veneers on full coverage crowns in relation to supporting core materials

    PubMed Central

    Agustín-Panadero, Rubén; Román-Rodriguez, Juan L.; Solá-Ruíz, María F.; Granell-Ruíz, María; Fons-Font, Antonio

    2013-01-01

    Objectives: To observe porcelain veneer behavior of zirconia and metal-ceramic full coverage crowns when subjected to compression testing, comparing zirconia cores to metal cores. Study Design: The porcelain fracture surfaces of 120 full coverage crowns (60 with a metal core and 60 with a zirconia core) subjected to static load (compression) testing were analyzed. Image analysis was performed using macroscopic processing with 8x and 12x enlargement. Five samples from each group were prepared and underwent scanning electron microscope (SEM) analysis in order to make a fractographic study of fracture propagation in the contact area and composition analysis in the most significant areas of the specimen. Results: Statistically significant differences in fracture type (cohesive or adhesive) were found between the metal-ceramic and zirconia groups: the incidence of adhesive fracture was seen to be greater in metal-ceramic groups (92%) and cohesive fracture was more frequent in zirconium oxide groups (72%). The fracture propagation pattern was on the periphery of the contact area in the full coverage crown restorations selected for fractographic study. Conclusions: The greater frequency of cohesive fracture in restorations with zirconia cores indicates that their behavior is inadequate compared to metal-ceramic restorations and that further research is needed to improve their clinical performance. Key words:Zirconia, zirconium oxide, fractography, composition, porcelain veneers, fracture, cohesive, adhesive. PMID:24455092

  5. Stress and Reliability Analysis of a Metal-Ceramic Dental Crown

    NASA Technical Reports Server (NTRS)

    Anusavice, Kenneth J; Sokolowski, Todd M.; Hojjatie, Barry; Nemeth, Noel N.

    1996-01-01

    Interaction of mechanical and thermal stresses with the flaws and microcracks within the ceramic region of metal-ceramic dental crowns can result in catastrophic or delayed failure of these restorations. The objective of this study was to determine the combined influence of induced functional stresses and pre-existing flaws and microcracks on the time-dependent probability of failure of a metal-ceramic molar crown. A three-dimensional finite element model of a porcelain fused-to-metal (PFM) molar crown was developed using the ANSYS finite element program. The crown consisted of a body porcelain, opaque porcelain, and a metal substrate. The model had a 300 Newton load applied perpendicular to one cusp, a load of 30ON applied at 30 degrees from the perpendicular load case, directed toward the center, and a 600 Newton vertical load. Ceramic specimens were subjected to a biaxial flexure test and the load-to-failure of each specimen was measured. The results of the finite element stress analysis and the flexure tests were incorporated in the NASA developed CARES/LIFE program to determine the Weibull and fatigue parameters and time-dependent fracture reliability of the PFM crown. CARES/LIFE calculates the time-dependent reliability of monolithic ceramic components subjected to thermomechanical and/Or proof test loading. This program is an extension of the CARES (Ceramics Analysis and Reliability Evaluation of Structures) computer program.

  6. Potential countersample materials for in vitro simulation wear testing.

    PubMed

    Shortall, Adrian C; Hu, Xiao Q; Marquis, Peter M

    2002-05-01

    Any laboratory investigation of the wear resistance of dental materials needs to consider oral conditions so that in vitro wear results can be correlated with in vivo findings. The choice of the countersample is a critical factor in establishing the pattern of tribological wear and in achieving an efficient in vitro wear testing system. This research investigated the wear behavior and surface characteristics associated with three candidate countersample materials used for in vitro wear testing in order to identify a possible suitable substitute for human dental enamel. Three candidate materials, stainless steel, steatite and dental porcelain were evaluated and compared to human enamel. A variety of factors including hardness, wear surface evolution and frictional coefficients were considered, relative to the tribology of the in vivo situation. The results suggested that the dental porcelain investigated bore the closest similarity to human enamel of the materials investigated. Assessment of potential countersample materials should be based on the essential tribological simulation supported by investigations of mechanical, chemical and structural properties. The selected dental porcelain had the best simulating ability among the three selected countersample materials and this class of material may be considered as a possible countersample material for in vitro wear test purposes. Further studies are required, employing a wider range of dental ceramics, in order to optimise the choice of countersample material for standardized in vitro wear testing.

  7. Improvements of gas-fired kiln by use of a microcomputer control system for the porcelain manufacture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loong, H.; Liang, C.C.; Tseng, K.T.

    1988-01-01

    The use of microcomputer control system to gas-fired kiln not only enhanced the porcelain kiln's productivity from 75% to 95% but also saved its operation cost around US$ 200,000 per year. The self-designed microcomputer control system can simultaneous set and control the firing conditions of the period kiln which was built up in our laboratory. Our period kiln having volume of 4 M/sup 3/ was insulated by ceramic fiber which is different from use of refractory in traditional kilns. At the bottom of the kiln is an off-gas tunnel connected with a chimney. Besides the auto start-up and continuous operationmore » of kiln, the main functions of this microcomputer control system are summarized.« less

  8. [Computer aided design and manufacture of the porcelain fused to metal crown].

    PubMed

    Nie, Xin; Cheng, Xiaosheng; Dai, Ning; Yu, Qing; Hao, Guodong; Sun, Quanping

    2009-04-01

    In order to satisfy the current demand for fast and high-quality prosthodontics, we have carried out a research in the fabrication process of the porcelain fused to metal crown on molar with CAD/CAM technology. Firstly, we get the data of the surface mesh on preparation teeth through a 3D-optical grating measuring system. Then, we reconstruct the 3D-model crown with the computer-aided design software which was developed by ourselves. Finally, with the 3D-model data, we produce a metallic crown on a high-speed CNC carving machine. The result has proved that the metallic crown can match the preparation teeth ideally. The fabrication process is reliable and efficient, and the restoration is precise and steady in quality.

  9. [The use of computer-aided colorimeter in porcelain-fused-to-metal (PFM) crowns among patients with special colored teeth].

    PubMed

    Fu, Yuan-fei; Weng, Wei-min

    2004-02-01

    To evaluate the roll of ShadeEye-NCC, a computer-aided colorimeter, in Porcelain-Fused-to-Metal crowns among patients with special colored Teeth. The first step was to choose the proper patients. The next was to use the colorimeter to measure the base shade of tooth and fabricate the PFM crowns according to the recipe given by the colorimeter. At last, the effects of the PFM crowns were evaluated subjectively by patients and doctor. The satisfaction rates of patients and doctor were 83.7% and 81.4% respectively, there was no significant difference between the two rates. The computer-aided colorimeter can offer good base shade recipe for fabricating PFM crowns of patients with special colored teeth.

  10. The effect of chemical disinfectants on the color of a porcelain shade guide.

    PubMed

    ArRejaie, Aws S

    2014-07-01

    To evaluate the effect of long term utilization of chemical disinfectants on the color of porcelain shade guides. three chemical disinfectants were used in this study: Minuten spray, Lysol ICQuaternary Disinfectant Cleaner (QDC), and Lysol IC Ready to Use Disinfectant Cleaner (RDC). Simulation of disinfecting cycles for one year, two years, and three years were done on Vita 3D master shade guide. Color differences were determined by visual inspection and analyzing ΔE. ΔE values were significantly below the perceptible (ΔE=1) and the clinically acceptable (ΔE=3.7) thresholds. Simulated utilization of Minuten Spray, Lysol IC (QDC), and Lysol (RDC) disinfectants for up to three years didn't cause a clinically significant difference in the color of VITA Toothguide 3D-Master Shade Guide.

  11. [An experimental study of the wear behavior of dental feldspathic glass-ceramic and lithium disilicate glass-ceramic].

    PubMed

    Tian, Bei-min; Zhang, Shao-feng; He, Lin; Guo, Jia-wen; Yu, Jin-tao; Wu, Xiao-hong

    2013-11-01

    To investigate the tribology characteristics of two ceramic materials in vitro:feldspathic glass-ceramic (veneer porcelain) and lithium disilicate glass-ceramic (heat-pressed ceramic), and to evaluate the wear resistance of different ceramic materials from the dynamic chewing perspective. Wear tests were performed in simulated oral environment with stainless steel ball antagonists (r = 3 mm), veneer porcelain (CERAMCO 3) and heat-pressed ceramic (IPS e.max Press HT type) in the chewing simulator. The tribological tests were carried out under artificial saliva lubrication condition in room temperature with a vertical load of 10 N for 1.2×10(6) cycles (f = 1.5 Hz, uniform circular motion, revolving speed = 90 r/min, radius = 0.5 mm). The wear volumes were measured using three-dimensional profiling, and surface microscopic morphology were observed using scanning electron microscopy at time point of 200 000, 400 000, 600 000, 800 000, 1 000 000, and 1 200 000 cycles. In a simulated oral environment, the wear rates of veneer porcelain were (0.001 20 ± 0.00 018) , (0.000 10 ± 0.000 03) , (0.000 50 ± 0.000 05), (0.000 10 ± 0.000 02) , (0.004 10 ± 0.000 38) , and (0.019 00 ± 0.003 53) (×10(-4) mm(3)/cycles) at 200 000, 400 000, 600 000, 800 000, 1 000 000, 1 200 000 cycles. The wear rates of heat-pressed ceramic were (0.139 50 ± 0.030 94), (0.124 40 ± 0.031 20), (0.054 80 ± 0.005 38), (0.038 80 ± 0.006 10), (0.011 10 ± 0.003 75), (0.198 90 ± 0.045 80) (×10(-4) mm(3)/cycles) at 200 000, 400 000, 600 000, 800 000, 1 000 000, 1 200 000 cycles. Three stages were observed in the wear loss process of the two materials: running-in stage, steady wear stage and severe wear stage. In running-in and steady wear stage, the shallow wear tracks of veneer porcelain were produced by the fatigue effect.While in severe wear stage, the wear tracks turned into ploughing. In running-in stage, the surface of heat-pressed ceramic was characterized by dense and shallow ploughing. In steady wear stage, the wear tracks turned into flake peeling produced by fatigue effect. At last, the whole layer was worn off by the effects of ploughing. In a simulated oral environment, the wear rate and wear loss of heat-pressed ceramic are greater than that of veneer porcelain.

  12. Comparison of Marginal and Internal Adaptation of Heat-Pressed and CAD/CAM Porcelain Laminate Veneers and a 2-Year Follow-Up.

    PubMed

    Yuce, Mert; Ulusoy, Mubin; Turk, Ayse Gozde

    2017-12-22

    To compare marginal and internal adaptations of porcelain laminate veneers fabricated with heat-pressed and CAD/CAM techniques, and to evaluate the clinical performances 2 years after cementation. Thirty heat-pressed and 31 CAD/CAM porcelain laminate veneers were fabricated for 12 patients. Silicone replicas of each veneer were obtained. Replicas were sectioned into 4 parts to measure adaptations of the veneers. A stereomicroscope was used to measure from 3 locations of replicas for marginal, and 9 locations for internal adaptations at 40x magnification. Clinical evaluations were done at baseline and 6, 12, 18, and 24 months after cementation according to the modified United States Public Health Service (USPHS) criteria. Independent samples t-test compared the adaptation values between heat-pressed and CAD/CAM groups. Paired t-test was used to evaluate marginal and internal adaptations of each group. Differences between the modified USPHS criteria ratings of heat-pressed and CAD/CAM groups were determined by the Mann-Whitney U test. Kaplan-Meier analysis was used to analyze the survival ratings of the veneers (p < 0.05). The mean marginal adaptation values of heat-pressed and CAD/CAM veneers were 295 and 314.98 μm, respectively, and there was no statistically significant difference (p = 0.541). Internal adaptation values of groups were not statistically different either (201.82 μm for heat pressed; 195.47 μm for CAD/CAM p = 0.734). When marginal and internal adaptation values were compared within groups, there were significant differences both for heat-pressed (p < 0.001) and CAD/CAM (p < 0.001). All veneers were rated 100% satisfactory during the 2-year period. Within the limitations of this study, fabrication method, whether CAD/CAM or heat-pressed, had no effect on the marginal and internal adaptation of porcelain laminate veneers. The results showed that both fabrication techniques performed well after 2 years of clinical performance. © 2017 by the American College of Prosthodontists.

  13. Effect of core thickness differences on post-fatigue indentation fracture resistance of veneered zirconia crowns.

    PubMed

    Alhasanyah, Abdulrahman; Vaidyanathan, Tritala K; Flinton, Robert J

    2013-07-01

    Despite the excellent esthetics of veneered zirconia crowns, the incidence of chipping and fracture of veneer porcelain on zirconia crowns has been recognized to be higher than in metal ceramic crowns. The objective of this investigation was to study the effect of selected variations in core thickness on the post-fatigue fracture resistance of veneer porcelain on zirconia crowns. Zirconia crowns for veneering were prepared with three thickness designs of (a) uniform 0.6-mm thick core (group A), (b) extra-thick 1.7 mm occlusal core support (group B), and (c) uniform 1.2-mm thick core (group C). The copings were virtually designed and milled by the CAD/CAM technique. Metal ceramic copings (group D) with the same design as in group C were used as controls. A sample size of N = 20 was used for each group. The copings were veneered with compatible porcelain and fatigue tested under a sinusoidal loading regimen. Loading was done with a 200 N maximum force amplitude under Hertzian axial loading conditions at the center of the crowns using a spherical tungsten carbide indenter. After 100,000 fatigue cycles, the crowns were axially loaded to fracture and maximum load levels before fracture was recorded. One-way ANOVA (P < 0.05) and post hoc Tukey tests (α = 0.05) were used to determine significant differences between means. The mean fracture failure load of group B was not significantly different from that of control group D. In contrast, the mean failure loads of groups A and C were significantly lower than that of control group D. Failure patterns also indicated distinct differences in failure mode distributions. The results suggest that proper occlusal core support improves veneer chipping fracture resistance in zirconia crowns. Extra-thick occlusal core support for porcelain veneer may significantly reduce the veneer chipping and fracture of zirconia crowns. This is suggested as an important consideration in the design of copings for zirconia crowns. © 2013 by the American College of Prosthodontists.

  14. Computer-assisted design/computer-assisted manufacturing zirconia implant fixed complete prostheses: clinical results and technical complications up to 4 years of function.

    PubMed

    Papaspyridakos, Panos; Lal, Kunal

    2013-06-01

    To report the clinical results and technical complications with computer-assisted design/computer-assisted manufacturing (CAD/CAM) zirconia, implant fixed complete dental prostheses (IFCDPs) after 2-4 years in function. Fourteen consecutive edentulous patients (16 edentulous arches) were included in this study. Ten of the patients were women and four were men, with an average age of 58 years (range: 35-71). Ten mandibular and six maxillary arches were restored with porcelain fused to zirconia (PFZ) IFCDPs. Of the 16 arches, 14 received one-piece and 2 received segmented two-piece IFCDPs, respectively. The mean clinical follow-up period was 3 years (range: 2-4). At the last recall appointment, biological and technical parameters of dental implant treatment were evaluated. The implant and prosthesis survival rate following prosthesis insertion was 100% up to 4-year follow-up. The prostheses in 11 of the 16 restored arches were structurally sound, exhibited favorable soft tissue response, esthetics, and patient satisfaction. Five IFCDPs (31.25%) in four patients exhibited porcelain veneer chipping. Chipping was minor in three prostheses (three patients) and was addressed intraorally with polishing (one prosthesis) or composite resin (two prostheses). One patient with maxillary and mandibular zirconia IFCDP exhibited major porcelain chipping fractures which had to be repaired in the laboratory. Function, esthetics, and patient satisfaction were not affected in three of the four fracture incidents. Median crestal bone loss was 0.1 mm (0.01-0.2 mm). The presence of parafunctional activity, the IFCDP as opposing dentition, and the absence of occlusal night guard were associated with all the incidents of ceramic chipping. CAD/CAM zirconia IFCDPs are viable prosthetic treatment after 2-4 years in function, but not without complications. The porcelain chipping/fracture was the most frequent technical complication, with a 31.25% chipping rate at the prosthesis level. Despite the technical complications, increased patient satisfaction was noted. © 2012 John Wiley & Sons A/S.

  15. The Effect of Chemical Disinfectants on the Color of a Porcelain Shade Guide

    PubMed Central

    ArRejaie, Aws S.

    2014-01-01

    Objective To evaluate the effect of long term utilization of chemical disinfectants on the color of porcelain shade guides. Methodology three chemical disinfectants were used in this study: Minuten spray, Lysol ICQuaternary Disinfectant Cleaner (QDC), and Lysol IC Ready to Use Disinfectant Cleaner (RDC). Simulation of disinfecting cycles for one year, two years, and three years were done on Vita 3D master shade guide. Color differences were determined by visual inspection and analyzing ΔE. Results ΔE values were significantly below the perceptible (ΔE=1) and the clinically acceptable (ΔE=3.7) thresholds. Conclusions Simulated utilization of Minuten Spray, Lysol IC (QDC), and Lysol (RDC) disinfectants for up to three years didn’t cause a clinically significant difference in the color of VITA Toothguide 3D-Master Shade Guide. PMID:25505865

  16. Rehabilitation of a patient with amelogenesis imperfecta using porcelain veneers and CAD/CAM polymer restorations: A clinical report.

    PubMed

    Saeidi Pour, Reza; Edelhoff, Daniel; Prandtner, Otto; Liebermann, Anja

    2015-01-01

    The complete dental rehabilitation of patients with a vertical dimension loss (VDL) caused by structural enamel deficits associated with amelogenesis imperfecta (AI) represents a difficult challenge for restorative teams. Accurate analysis and treatment planning that includes esthetic and functional evaluations and adequate material selection are important prerequisites for successful results. Long-term provisional restorations play an important role in exploring and elucidating the patients' esthetic demands and functional needs. Restorative treatment options can vary from requiring only oral hygiene instructions to extensive dental restorations that include composite fillings, ceramic veneers, metal-ceramic, or all-ceramic crowns. This case report describes a full-mouth rehabilitation of a patient with amelogenesis imperfecta including the case planning, bite replacement, preparation, and restoration setting steps with an experimental CAD/CAM polymer and porcelain veneers.

  17. [Influence of different surface treatments on porcelain surface topography].

    PubMed

    Tai, Yinxia; Zhu, Xianchun; Sen, Yan; Liu, Chang; Zhang, Xian; Shi, Xueming

    2013-02-01

    To evaluate the influence of different surface treatments on porcelain surface topography. Metal ceramic prostheses in 6 groups were treated according to the different surface treatment methods, and the surface topography was observed through scanning electron microscope (SEM). Group A was the control one (untreated), group B was etched by 9.6% hydrofluoric acid(HF), group C was deglazed by grinding and then etched by 9.6% HF, group D was treated with Nd: YAG laser irradiation(0.75 W) and HF etching, group E was treated with Nd: YAG laser irradiation (1.05 W) and HF etching, and group F was treated with laser irradiation (1.45 W) and HF etching. Surface topography was different in different groups. A lot of inerratic cracks with the shapes of rhombuses and grid, and crater with a shape of circle were observed on the ceramic surface after treatment with energy parameters of 1.05 W Nd: YAG laser irradiation and 9.6% HF etching (group E). Surface topography showed a lot of concaves on the inner wall of the cracks, and the concaves with diameter of 1-5 microm could be observed on the inner wall of the holes, which had a diameter of 20 microm under SEM. The use of Nd: YAG laser irradiation with the energy parameters of 1.05 W and the HF with a concentration of 9.6% can evenly coarsen the porcelain surface, that is an effective surface treatment method.

  18. Subcritical crack growth in porcelains, glass-ceramics, and glass-infiltrated alumina composite for dental restorations.

    PubMed

    Gonzaga, Carla Castiglia; Yoshimura, Humberto Naoyuki; Cesar, Paulo Francisco; Miranda, Walter Gomes

    2009-05-01

    The objective was to compare fracture toughness (K(Ic)), stress corrosion susceptibility coefficient (n), and stress intensity factor threshold for crack propagation (K(I0)) of two porcelains [VM7/Vita (V) and d.Sign/Ivoclar (D)], two glass-ceramics [Empress/Ivolcar (E1) and Empress2/Ivlocar (E2)] and a glass-infiltrated alumina composite [In-Ceram Alumina/Vita (IC)]. Disks were constructed according to each manufacturer's processing method, and polished before induction of cracks by a Vickers indenter. Crack lengths were measured under optical microscopy at times between 0.1 and 100 h. Specimens were stored in artificial saliva at 37 degrees C during the whole experiment. K(Ic) and n were determined using indentation fracture method. K(I0) was determined by plotting log crack velocity versus log K(I). Microstructure characterization was carried out under SEM, EDS, X-ray diffraction and X-ray fluorescence. IC and E2 presented higher K(Ic) and K(I0) compared to E1, V, and D. IC presented the highest n value, followed by E2, D, E1, and V in a decreasing order. V and D presented similar K(Ic), but porcelain V showed higher K(I0) and lower n compared to D. Microstructure features (volume fraction, size, aspect ratio of crystalline phases and chemical composition of glassy matrix) determined K(Ic). The increase of K(Ic) value favored the increases of n and K(I0).

  19. Color stability of different denture teeth materials: an in vitro study.

    PubMed

    Mutlu-Sagesen, L; Ergün, G; Ozkan, Y; Bek, B

    2001-09-01

    The aim of this in vitro study was to compare the color stability of commercially available porcelain, reinforced acrylic, and conventional acrylic denture teeth materials used in removable prostheses. Two brands of porcelain (Unilux-Enta Lactona-Holland and Vivoperl-Ivoclar-Liechtenstein), 2 brands of reinforced acrylic (Optodent-Bayer-Germany and Ivolek-Ivoclar-Liechtenstein), and 2 brands of conventional acrylic (Isodent-Güney Diş Deposu-Turkey and Samed-Turkey), were made, for a total of 6 different denture teeth groups. Denture teeth were subjected to 3 staining solutions (filtered coffee, tea, and cola) and distilled water. From each group of denture teeth, 4 sets of maxillary anterior denture teeth were immersed in each of the 4 solutions. The color values of denture teeth were measured colorimetrically with the Gardner XL 20 Tristimulus Colorimeter (Gardner Lab. Inc., Bethesda, Maryland, USA). Color changes were characterized in the CIEL*a*b* color space. Color change values were determined after 1 day, 1 week, 2 weeks, and 4 weeks. The color difference values were calculated and then evaluated by two-way ANOVA statistically. The filtered coffee solution was found to be more chromogenic than the other 2 staining solutions, while porcelain denture teeth materials were more color stable. Assuming the color change of deltaE* < 1.0 as a discernible limit and deltaE* = 3.3 as an acceptable value, the filtered coffee, tea, and cola had slight staining effects on all 6 groups of denture teeth.

  20. Kiln control

    NASA Astrophysics Data System (ADS)

    Adams, Bob

    2016-03-01

    In reply to the feature article “Bubble signatures revealed in antique artefacts” by Stephen C Wallace and Geraldine Kenney-Wallace (January pp34-38) about how physics can help to tell a real antique porcelain object from a fake.

  1. Bubble signatures revealed in antique artefacts

    NASA Astrophysics Data System (ADS)

    Wallace, Stephen C.; Kenney-Wallace, Geraldine

    2016-01-01

    Antique Chinese porcelain can fetch thousands of dollars on the art market. Stephen C Wallace and Geraldine Kenney-Wallace explain how their physics-based technique could help collectors and connoisseurs to tell a real antique object from a fake.

  2. Fire effects on prehistoric ceramics [Chapter 3

    Treesearch

    Trisha Rude; Anne Trinkle Jones

    2012-01-01

    In North America, prehistoric pottery is primarily earthenware (a porous ceramic, fired at a relatively low temperature). It is not glass-like or dense like other kinds of pottery such as stoneware and porcelain (see chapter 6).

  3. 21 CFR 872.3910 - Backing and facing for an artificial tooth.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... use in fabrication of a fixed or removable dental appliance, such as a crown or bridge. The backing... is made of porcelain or plastic. (b) Classification. Class I (general controls). The device is exempt...

  4. Study of surface topography, roughness, and microleakage after dental preparation with different instrumentation.

    PubMed

    Solá-Ruiz, Ma Fernanda; Faus-Matoses, Ignacio; Del Rio Highsmith, Jamie; Fons-Font, Antonio

    2014-01-01

    The purpose of this study was to compare the differences in surface characteristics and roughness of teeth finished for porcelain veneer laminates using different instrumentation and to assess their influence on microleakage. Fifty-six extracted human maxillary central incisors were divided randomly into two groups: Group HsR teeth were finished with a high-speed handpiece with diamond burs; group SO teeth were finished with a sonic oscillating diamond instrument. Porcelain veneers were bonded to 24 teeth in each group. Microleakage was measured in the cervical area. Four remaining teeth in each group were examined using confocal laser-scanning microscopy and scanning electron microscopy. Oscillating instruments produced a rougher dentinal surface (Ra values; P = .029) than those finished with high-speed rotary technology. There is less microleakage when bonded restoration edges are situated over dentin that has been finished with sonic oscillating instrumentation (P = .006).

  5. Process Development of Porcelain Ceramic Material with Binder Jetting Process for Dental Applications

    NASA Astrophysics Data System (ADS)

    Miyanaji, Hadi; Zhang, Shanshan; Lassell, Austin; Zandinejad, Amirali; Yang, Li

    2016-03-01

    Custom ceramic structures possess significant potentials in many applications such as dentistry and aerospace where extreme environments are present. Specifically, highly customized geometries with adequate performance are needed for various dental prostheses applications. This paper demonstrates the development of process and post-process parameters for a dental porcelain ceramic material using binder jetting additive manufacturing (AM). Various process parameters such as binder amount, drying power level, drying time and powder spread speed were studied experimentally for their effect on geometrical and mechanical characteristics of green parts. In addition, the effects of sintering and printing parameters on the qualities of the densified ceramic structures were also investigated experimentally. The results provide insights into the process-property relationships for the binder jetting AM process, and some of the challenges of the process that need to be further characterized for the successful adoption of the binder jetting technology in high quality ceramic fabrications are discussed.

  6. An in vitro study to evaluate the difference in shade between commercially available shade guides and glazed porcelain.

    PubMed

    Manimaran, P; Sadan, D Sai

    2016-10-01

    Smile is one of the most important interactive communication skills of a person. A smile is the key factor for an aesthetic appearance. Hence aesthetics is one of the motivating factor for the patients to seek dental care. Correction of unaesthetic appearance gives a positive effect to the self esteem of the patient. The aim of this study was to compare the difference in the shade between the commercially available shade guides namely Vita Classical And Ivoclar Chromascop and the fired porcelain samples fabricated using Vita Zahnfabrik VMK 95 and Ivoclar Classic Materials respectively. The objective of this study was to obtain a matching brand of material that has a particular shade tab among the brands used. To conclude, Ivoclar material matched the chromascop shade guide better than the vita material matched the vita classic shade guide.

  7. Mössbauer analysis of the firing process of the sky-green glaze of the imitative ancient Chinese Ru porcelain

    NASA Astrophysics Data System (ADS)

    Songhua, Chen; Zhengyao, Gao; Guoju, Hu; Xiande, Chen

    1994-12-01

    The variation of the Mössbauer parameters of the imitative ancient Ru porcelain skygreen glaze with the firing conditions is studied in detail in the present paper. The Mössbauer spectra show that the sky-green glaze contains three kinds of iron minerals, i.e. the structural iron (Fe2+ and Fe3+); Fe2O3 and Fe3O4. The relative intensity of the paramagnetic peak Fe2+ increases and the magnetic ratio of the magnetic peak decreases with increasing temperature. Based on the variation of the quadrupole splitting ( QS) of the paramagnetic peak Fe2+, the phase transformation characteristics of the sky-green glaze in the firing process is discussed. The coloring mechanism of the sky-green glaze and the variation of its magnetism in the firing process are also investigated in the present paper.

  8. Esthetic Rehabilitation of the Smile with No-Prep Porcelain Laminates and Partial Veneers

    PubMed Central

    Farias-Neto, Arcelino; Gomes, Edna Maria da Cunha Ferreira; Sánchez-Ayala, Alfonso; Sánchez-Ayala, Alejandro; Vilanova, Larissa Soares Reis

    2015-01-01

    Rehabilitation of patients with anterior conoid teeth may present a challenge for the clinician, especially when trying to mimic the nature with composite resins. This clinical report exemplifies how a patient with conoid upper lateral incisors was rehabilitated with minimally invasive adhesive restorations. Following diagnostic wax-up and cosmetic mock-up, no-prep veneers and ceramic fragments (partial veneers) were constructed with feldspathic porcelain. This restorative material presents excellent reproduction of the optical properties of the dental structure, especially at minimal thicknesses. In this paper, the details about the treatment are described. A very pleasing outcome was achieved, confirming that minimally invasive adhesive restorations are an excellent option for situations in which the dental elements are healthy, and can be modified exclusively by adding material and the patient does not want to suffer any wear on the teeth. PMID:26568893

  9. Minimally invasive restoration of a maxillary central incisor with a partial veneer.

    PubMed

    Horvath, Sebastian; Schulz, Claus-Peter

    2012-01-01

    Minimally invasive treatment modalities allow for the preservation of sound tooth substance. However, by limiting the preparation to the extent of a defect, the transition between restoration and natural tooth may be moved to more visible areas. The materials available for the restoration of a limited defect in the anterior area are either resin composite materials or porcelain. A patient was presented who asked for the replacement of a discolored filling on the maxillary right central incisor. Tooth preparation was limited to the extent of the old filling, and a porcelain partial veneer restoration was fabricated. Despite the horizontal finish line in the middle of the clinical crown, a result could be achieved that was regarded as a success by the patient. This type of restoration proves to be a suitable alternative to direct composite restorations in the anterior area for the reconstruction of a limited defect, eg, due to a dental trauma.

  10. [The effect of core veneer thickness ratio on the flexural strength of diatomite-based dental ceramic].

    PubMed

    Jiang, Jie; Zhang, Xin; Gao, Mei-qin; Zhang, Fei-min; Lu, Xiao-li

    2015-06-01

    To evaluate the effect of different core veneer thickness ratios on the flexural strength and failure mode of bilayered diatomite-based dental ceramics. Diatomite-based dental ceramics blocks (16 mm×5.4 mm×1 mm) were sintered with different thickness of veneer porcelains: 0 mm (group A), 0.6 mm (group B), 0.8 mm (group C) and 1.0 mm (group D). Flexural strength was detected and scanning electron microscope was used to observe the interface microstructure. Statistical analysis was performed using SPSS 17.0 software package. With the increase of the thickness of the veneer porcelain, flexural strength of group C showed highest flexural strength up to (277.24±5.47) MPa. Different core veneer thickness ratios can significantly influence the flexural strength of bilayered diatomite-based dental ceramics. Supported by Science and Technology Projects of Nantong City (HS2013010).

  11. Metal-ceramic bond strength between a feldspathic porcelain and a Co-Cr alloy fabricated with Direct Metal Laser Sintering technique.

    PubMed

    Dimitriadis, Konstantinos; Spyropoulos, Konstantinos; Papadopoulos, Triantafillos

    2018-02-01

    The aim of the present study was to record the metal-ceramic bond strength of a feldspathic dental porcelain and a Co-Cr alloy, using the Direct Metal Laser Sintering technique (DMLS) for the fabrication of metal substrates. Ten metal substrates were fabricated with powder of a dental Co-Cr alloy using DMLS technique (test group) in dimensions according to ISO 9693. Another ten substrates were fabricated with a casing dental Co-Cr alloy using classic casting technique (control group) for comparison. Another three substrates were fabricated using each technique to record the Modulus of Elasticity ( E ) of the used alloys. All substrates were examined to record external and internal porosity. Feldspathic porcelain was applied on the substrates. Specimens were tested using the three-point bending test. The failure mode was determined using optical and scanning electron microscopy. The statistical analysis was performed using t-test. Substrates prepared using DMLS technique did not show internal porosity as compared to those produced using the casting technique. The E of control and test group was 222 ± 5.13 GPa and 227 ± 3 GPa, respectively. The bond strength was 51.87 ± 7.50 MPa for test group and 54.60 ± 6.20 MPa for control group. No statistically significant differences between the two groups were recorded. The mode of failure was mainly cohesive for all specimens. Specimens produced by the DMLS technique cover the lowest acceptable metal-ceramic bond strength of 25 MPa specified in ISO 9693 and present satisfactory bond strength for clinical use.

  12. The effect of repeated firings on the color change of dental ceramics using different glazing methods

    PubMed Central

    Yılmaz, Kerem; Ozturk, Caner

    2014-01-01

    PURPOSE Surface color is one of the main criteria to obtain an ideal esthetic. Many factors such as the type of the material, surface specifications, number of firings, firing temperature and thickness of the porcelain are all important to provide an unchanged surface color in dental ceramics. The aim of this study was to evaluate the color changes in dental ceramics according to the material type and glazing methods, during the multiple firings. MATERIALS AND METHODS Three different types of dental ceramics (IPS Classical metal ceramic, Empress Esthetic and Empress 2 ceramics) were used in the study. Porcelains were evaluated under five main groups according to glaze and natural glaze methods. Color changes (ΔE) and changes in color parameters (ΔL, Δa, Δb) were determined using colorimeter during the control, the first, third, fifth, and seventh firings. The statistical analysis of the results was performed using ANOVA and Tukey test. RESULTS The color changes which occurred upon material-method-firing interaction were statistically significant (P<.05). ΔE, ΔL, Δa and Δb values also demonstrated a negative trend. The MC-G group was less affected in terms of color changes compared to other groups. In all-ceramic specimens, the surface color was significantly affected by multiple firings. CONCLUSION Firing detrimentally affected the structure of the porcelain surface and hence caused fading of the color and prominence of yellow and red characters. Compressible all-ceramics were remarkably affected by repeated firings due to their crystalline structure. PMID:25551001

  13. A comparison of laser-welded titanium and conventional cast frameworks supported by implants in the partially edentulous jaw: a 3-year prospective multicenter study.

    PubMed

    Jemt, T; Henry, P; Lindén, B; Naert, I; Weber, H; Bergström, C

    2000-01-01

    The purpose of this prospective multicenter study was to evaluate and compare the clinical performance of laser-welded titanium fixed partial implant-supported prostheses with conventional cast frameworks. Forty-two partially edentulous patients were provided with Brånemark system implants and arranged into 2 groups. Group A was provided with a conventional cast framework with porcelain veneers in one side of the jaw and a laser-welded titanium framework with low-fusing porcelain on the other side. The patients in group B had an old implant prosthesis replaced by a titanium framework prosthesis. The patients were followed for 3 years after prosthesis placement. Clinical and radiographic data were collected and analyzed. Only one implant was lost, and all prostheses were still in function after 3 years. The 2 framework designs showed similar clinical performance with few clinical complications. Only one abutment screw (1%) and 9 porcelain tooth units (5%) fractured. Four prostheses experienced loose gold screws (6%). In group A, marginal bone loss was similar for both designs of prostheses, with a mean of 1.0 mm and 0.3 mm in the maxilla and mandible, respectively. No bone loss was observed on average in group B. No significant relationship (P > 0.05) was observed between marginal bone loss and placement of prosthesis margin or prosthesis design. The use of laser-welded titanium frameworks seems to present similar clinical performance to conventional cast frameworks in partial implant situations after 3 years.

  14. Mono or polycrystalline alumina-modified hybrid ceramics.

    PubMed

    Kaizer, Marina R; Gonçalves, Ana Paula R; Soares, Priscilla B F; Zhang, Yu; Cesar, Paulo F; Cava, Sergio S; Moraes, Rafael R

    2016-03-01

    This study evaluated the effect of addition of alumina particles (polycrystalline or monocrystalline), with or without silica coating, on the optical and mechanical properties of a porcelain. Groups tested were: control (C), polycrystalline alumina (PA), polycrystalline alumina-silica (PAS), monocrystalline alumina (MA), monocrystalline alumina-silica (MAS). Polycrystalline alumina powder was synthesized using a polymeric precursor method; a commercially available monocrystalline alumina powder (sapphire) was acquired. Silica coating was obtained by immersing alumina powders in a tetraethylorthosilicate solution, followed by heat-treatment. Electrostatic stable suspension method was used to ensure homogenous dispersion of the alumina particles within the porcelain powder. The ceramic specimens were obtained by heat-pressing. Microstructure, translucency parameter, contrast ratio, opalescence index, porosity, biaxial flexural strength, roughness, and elastic constants were characterized. A better interaction between glass matrix and silica coated crystalline particles is suggested in some analyses, yet further investigation is needed to confirm it. The materials did not present significant differences in biaxial flexural strength, due to the presence of higher porosity in the groups with alumina addition. Elastic modulus was higher for MA and MAS groups. Also, these were the groups with optical qualities and roughness closer to control. The PA and PAS groups were considerably more opaque as well as rougher. Porcelains with addition of monocrystalline particles presented superior esthetic qualities compared to those with polycrystalline particles. In order to eliminate the porosity in the ceramic materials investigated herein, processing parameters need to be optimized as well as different glass frites should be tested. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  15. [Fracture resistance of Procera Allceram depending on the framework design--an in vitro study].

    PubMed

    Hagmann, Edgar; Marinello, Carlo P; Zitzmann, Nicola U

    2006-01-01

    Procera AllCeram is one of the all-ceramic systems with an aluminium-oxide core employing CAD/CAM technology. The aim of the current study was to investigate the fracture resistance of Procera AllCeram full-ceramic crowns with a reduced core design compared to the conventional method. In addition, a possible influence of the preparation form (molars or premolars) and the cementation material (glas-ionomer or composite) was analyzed. For both preparation forms, 30 ceramic cores with reduced margins (collarless cores, test) and 30 cores with extended cores (control) were veneered with porcelain in a standardized procedure (total 120 crowns). For the test group, Procera-AllCeram-margin ceramic material was used for the porcelain collar. 40 crowns each were cemented on stainless steel dies with either Ketac-Cem Aplicap or Panavia F. The additional 40 crowns were set on polyurethane dies without cementation and occlusally loaded until fracture occurred. Among the molar crowns, no differences were observed in fracture resistance neither for the different core designs (test or control) nor for the cementation materials. For the premolar form, fusing of a porcelain margin was associated with a reduction in fracture resistance, while the use of composite cement was accompanied with an increase. The present in vitro results indicate that for Procera AllCeram crowns with a highly undulating preparation margin, a conventional core design combined with adhesive cementation is preferable, especially in the posterior region due to higher chewing forces; this assumption needs to be proven in clinical studies.

  16. Reliability and failure modes of implant-supported zirconium-oxide fixed dental prostheses related to veneering techniques

    PubMed Central

    Baldassarri, Marta; Zhang, Yu; Thompson, Van P.; Rekow, Elizabeth D.; Stappert, Christian F. J.

    2011-01-01

    Summary Objectives To compare fatigue failure modes and reliability of hand-veneered and over-pressed implant-supported three-unit zirconium-oxide fixed-dental-prostheses(FDPs). Methods Sixty-four custom-made zirconium-oxide abutments (n=32/group) and thirty-two zirconium-oxide FDP-frameworks were CAD/CAM manufactured. Frameworks were veneered with hand-built up or over-pressed porcelain (n=16/group). Step-stress-accelerated-life-testing (SSALT) was performed in water applying a distributed contact load at the buccal cusp-pontic-area. Post failure examinations were carried out using optical (polarized-reflected-light) and scanning electron microscopy (SEM) to visualize crack propagation and failure modes. Reliability was compared using cumulative-damage step-stress analysis (Alta-7-Pro, Reliasoft). Results Crack propagation was observed in the veneering porcelain during fatigue. The majority of zirconium-oxide FDPs demonstrated porcelain chipping as the dominant failure mode. Nevertheless, fracture of the zirconium-oxide frameworks was also observed. Over-pressed FDPs failed earlier at a mean failure load of 696 ± 149 N relative to hand-veneered at 882 ± 61 N (profile I). Weibull-stress-number of cycles-unreliability-curves were generated. The reliability (2-sided at 90% confidence bounds) for a 400N load at 100K cycles indicated values of 0.84 (0.98-0.24) for the hand-veneered FDPs and 0.50 (0.82-0.09) for their over-pressed counterparts. Conclusions Both zirconium-oxide FDP systems were resistant under accelerated-life-time-testing. Over-pressed specimens were more susceptible to fatigue loading with earlier veneer chipping. PMID:21557985

  17. Microscopic analysis of "iron spot" on blue-and-white porcelain from Jingdezhen imperial kiln in early Ming dynasty (14th-15th century).

    PubMed

    Wang, Wenxuan; Zhu, Jian; Jiang, Jianxin; Xu, Changqing; Wu, Shurong; Guan, Li; Zhang, Zhaoxia; Wu, Menglei; Du, Jingnan

    2016-11-01

    "Sumali," as an imported cobalt ore from overseas, was a sort of precious and valuable pigment used for imperial kilns only, which produces characteristic "iron spot" to blue-and-white porcelain in early Ming Dynasty (A.D. 14th-15th century). Although there were some old studies on it, the morphology and formation of iron spot has not been fully investigated and understood. Therefore, five selected samples with typical spot from Jingdezhen imperial kiln in Ming Yongle periods (A.D. 1403-1424) were analyzed by various microscopic analysis including 3D digital microscope, SEM-EDS and EPMA. According to SEM images, samples can be divided into three groups: un-reflected "iron spot" without crystals, un-reflected "iron spot" with crystals and reflected "iron spot" with crystals. Furthermore, 3D micro-images revealed that "iron spots" separate out dendritic or snow-shaped crystals of iron only on and parallel to the surface of glaze for which "iron spot" show strong metallic luster. Combining with microscopic observation and microanalysis on crystallization and non-crystallization areas, it indicates that firing oxygen concentration is the ultimate causation of forming reflective iron spot which has a shallower distribution below the surface and limits crystals growing down. More details about characters of "iron spot" used "Sumali" were found and provided new clues to coloration, formation mechanism and porcelain producing technology of imperial kiln from 14th to 15th centuries of China. © 2016 Wiley Periodicals, Inc.

  18. 40 CFR 466.44 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false [Reserved] 466.44 Section 466.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Copper Basis Material Subcategory § 466.44 [Reserved] ...

  19. 40 CFR 466.44 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false [Reserved] 466.44 Section 466.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Copper Basis Material Subcategory § 466.44 [Reserved] ...

  20. [Comparison of the shear bond strength by using nano silica sol to zirconia basement and veneer porcelain].

    PubMed

    Wang, Si-qian; Zhang, Da-feng; Zhen, Tie-li; Yang, Jing-yuan; Lin, Ting-ting; Ma, Jian-feng

    2016-04-01

    To investigate the feasibility of using sol gel technique to produce thin layer nano silicon dioxide on zirconia ceramic surface and the effect of improving shear bond strength between zirconia and veneer porcelain. The presintered zirconia specimen was cut into a rectangle block piece (15 mm×10 mm×2.5 mm), a total of 40 pieces were obtained and divided into 4 groups, each group had 10 pieces. Four different treatments were used in each group respectively. Pieces in group A (control group) were only sintered at 1450°C to crystallization; pieces in group B underwent 30% nano silica sol infiltration first and then were sintered at 1450°C to crystallization; piece in group C underwent crystallization first at 1450°C, then 30% nano silica sol infiltration and were sintered at 1450°C again; pieces in group D was coated by nano silica sol and then sintered at 1450°C to crystallization; ten rectangle block pieces (12 mm×8 mm×2 mm) in group E were made. Cylinder veneers 5 mm in diameter and 4 mm in height were produced in each group and the shear bond strength was tested. Data were statistically analyzed by SPSS 19.0 software package. The shear bond strength of the 5 group specimens were: (28.12±2.95) MPa in group A, (31.09±3.94) MPa in group B, (25.60±2.45) MPa in group C, (31.75±4.90) MPa in group D, (28.67±3.95) MPa in group E, respectively. Significant differences existed between the 5 groups, and group C had significant difference compared with group B and D. CONCLUSIONS:① Use of nano silicon sol gel on presintered zirconia surface to make thin layer of nano silicon dioxide can improve the shear bond strength between zirconia and veneer; ②Using nano silicon sol gel on crystallization zirconia surface to make thin layer of nano silicon dioxide will decrease the shear bond strength between zirconia and veneer; ③ Zirconia veneer bilayer ceramic has the same shear bond strength with porcelain fused to Ni Cr alloy; ④Use of sol gel technique to produce thin layer nano silicon dioxide on zirconia ceramic surface is feasible and can improve shear bond strength between zirconia and veneer porcelain.

  1. Some new astronomical facilities in China

    NASA Astrophysics Data System (ADS)

    Wang, Shouguan

    1989-10-01

    For the 1990's, plans for some astronomical facilities and related research are being carried out in China. This report describes in some detail plans for radio astronomical facilities, a 150/220 cm Schmidt telescope, and experiments on a porcelain mirror material.

  2. 40 CFR 466.30 - Applicability; description of the aluminum basis material subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... aluminum basis material subcategory. 466.30 Section 466.30 Protection of Environment ENVIRONMENTAL... Aluminum Basis Material Subcategory § 466.30 Applicability; description of the aluminum basis material... into publicly owned treatment works from porcelain enameling of aluminum basis materials. ...

  3. 77 FR 49991 - Small Business Size Standards; Adoption of 2012 North American Industry Classification System for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-20

    ... Manufacturing. ......... 322215 Nonfolding Sanitary ......... 750 employees....... Food Container Manufacturing... Manufacturing. ......... 327113 Porcelain Electrical 500 employees. Supply Manufacturing. 327120 Clay Building N 2b 750 employees....... 327121 Brick and Structural 500 employees. Material and Clay Tile...

  4. 40 CFR 466.40 - Applicability; description of the copper basis material subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... copper basis material subcategory. 466.40 Section 466.40 Protection of Environment ENVIRONMENTAL... Copper Basis Material Subcategory § 466.40 Applicability; description of the copper basis material... into publicly owned treatment works from porcelain enameling of copper basis materials. ...

  5. 40 CFR 466.40 - Applicability; description of the copper basis material subcategory.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... copper basis material subcategory. 466.40 Section 466.40 Protection of Environment ENVIRONMENTAL... Copper Basis Material Subcategory § 466.40 Applicability; description of the copper basis material... into publicly owned treatment works from porcelain enameling of copper basis materials. ...

  6. Evaluation of the effect of a home bleaching agent on surface characteristics of indirect esthetic restorative materials--part II microhardness.

    PubMed

    Torabi, Kianoosh; Rasaeipour, Sasan; Ghodsi, Safoura; Khaledi, Amir Ali Reza; Vojdani, Mahroo

    2014-07-01

    The exponential usage of esthetic restorative materials is beholden to society needs and desires. Interaction between the bleaching agents and the esthetic restorative materials is of critical importance. This in vitro study has been conducted to evaluate the effect of a home bleaching agent, carbamide peroxide (CP) 38%, on the microhardness of the fiber reinforced composite (FRC), overglazed, autoglazed, or polished porcelain specimens. For overglazed, autoglazed, polished ceramics and also FRC cylindrical specimens (n = 20 per group) were prepared. The specimens were stored in distilled water at 37°C for 48 hours prior to testing. Six samples from each group were selected randomly as negative controls which were stored in distilled water at 37°C that was changed daily. CP 38% was applied on the test specimens for 15 minutes, twice a day for 14 days. By using Knoop-microhardness tester microhardness testing for baseline, control and test specimens was conducted. Data were statistically analyzed using paired t-test, Mann-Whitney test, and Kruskal-Wallis test. Home bleaching significantly decreased the surface microhardness of all the test samples (p < 0.05), whereas the control groups did not show statistically significant changes after 2 weeks. The polished porcelain and polished composite specimens showed the most significant change in microhard-ness after bleaching process (p < 0.05). Although the type of surface preparation affects the susceptibility of the porcelain surface to the bleaching agent, no special preparation can preclude such adverse effects. The contact of home bleaching agents with esthetic restorative materials is unavoidable. Therefore protecting these restorations from bleaching agents and reglazing or at least polishing the restorations after bleaching is recommended.

  7. Implant-level prostheses in the edentulous maxilla: a comparison with conventional abutment-level prostheses after 5 years of use.

    PubMed

    Hjalmarsson, Lars; Smedberg, Jan-Ivan; Pettersson, Mattias; Jemt, Torsten

    2011-01-01

    Long-term comparisons of frameworks at the implant or abutment level are not available, and knowledge of the clinical function of cobalt-chromium (Co-Cr) alloy frameworks is limited. Primarily, the aim of this study was to compare the 5-year clinical performance of frameworks with or without abutment connections to implants. Secondly, the outcomes of prostheses made from Co-Cr alloy with porcelain veneers to those made of commercially pure titanium (CP Ti) with acrylic veneers were compared. The test groups comprised patients treated with screw-retained fixed prostheses made at the implant level according to the Cresco method in either dental porcelain-veneered Co-Cr alloy (n = 15) or acrylic-veneered CP Ti (n = 25). A control group of 40 randomly selected patients were provided with prostheses made at the standard abutment level in CP Ti with acrylic veneers. For all patients, clinical and radiologic 5-year data were retrospectively collected and evaluated. Five-year implant cumulative survival rates (CSRs) were 98.6% and 97.6% for test and control groups, respectively (P > .05). No major differences in bone level were demonstrated between the groups after 5 years (P > .05). Significantly more complications occurred in the test groups compared to the control group (P < .01), with the most common complications being mucositis and fracture of veneers. After 5 years, the clinical outcomes of implant-level prostheses made of porcelain-veneered Co-Cr or acrylic-veneered CP Ti seem comparable to acrylic-veneered titanium prostheses made at the standard abutment level regarding implant CSR and bone levels. However, more complications were registered in implant-level prostheses compared to the standard abutment-level prostheses.

  8. Metformin treatment prevents gallstone formation but mimics porcelain gallbladder in C57Bl/6 mice.

    PubMed

    Dorvash, Mohammad Reza; Khoshnood, Mohammad Javad; Saber, Hossein; Dehghanian, Amirreza; Mosaddeghi, Pouria; Firouzabadi, Negar

    2018-06-05

    Gallstone disease (GD) is highly correlated with metabolic syndrome and its related illnesses including type II diabetes (DMII) and polycystic ovary syndrome (PCOS). While previous studies claimed that metformin decreases the chance of developing GD in PCOS patients, this phenomenon has not been investigated in animal models to date. Here we fed a high fat diet (HFD) containing 2% of cholesterol and 1% of cholic acid to ten-week-old male C57Bl/6 mice for 105 days. The groups were as follows: Low fat diet; HFD; HFD + Ursodeoxycholic acid (UDCA) (day 1-105); HFD + Metformin (day 1-105); HFD + Metformin (Met) (day 64-105). All drugs were administered by oral gavage (Met = 300 mg/kg & UDCA = 750 mg/kg). Serum lipid profile and gross organ examination were performed after euthanasia. A microscopic evaluation of the paraffin-embedded gallbladders was done after hematoxylin & eosin and Von Kossa staining. HFD successfully induces gallstone (4 out of 4 of the HFD members). While both UDCA and metformin (d 1-105) prevented gallstone formation and cholecystitis, Metformin (d 64-105) group had a few small stones. Additionally, metformin induces mucosal calcification in gallbladder (porcelain GB) of more than 80% of the HFD + Met (day 1-105) and HFD + Met (day 64-105) groups, collectively, which can be a potential problem by itself. While metformin shows a noticeable benefit towards GB health by reducing the chance for gallstone formation, if it induces porcelain gallbladder in humans as well, it might inflict patients with preventable medical charges. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. [Esthetic restoration for anterior teeth with the hot pressed porcelain laminate veneers].

    PubMed

    Xu, Shao-ping; Luo, Xiao-ping; Shi, Yu-juan

    2012-10-01

    To evaluate the esthetic effect of anterior porcelain veneers fabricated with the heat pressed glass ceramic. Thirty-two patients, who wanted to receive a aesthetic restorative treatment for 206 anterior teeth were selected. Among them, 20 were for dental fluorosis, 8 were for light tetracycline stained teeth, the other 4 were labial enamel hypoplasia or obvious crack on the surface of enamel. According to the color of adjacent teeth,skin and lips, heat pressed IPS e.max ingots of different color were chosen to mold the restorations. Afterwards, special straining technique was conducted on the marginal ridge and incisor ridge of the veneers after carefully trimmed in the mouth. Restorations were them bonded with Variolink II resin cement. After 7 years of follow-up, a modified USPHS criterion was used to evaluate the esthetic effect. The translucency of veneers was superior. Marginal integrity of the veneers was perfect and it docked well with the marginal terminate line of the abutment. There was no edge coloring after the veneers were used for 7 years, and the veneers produce an excellent chameleon effect by absorbing the color of adjacent teeth and gums, at the same time, veneers could produce a feature of surface morphology of natural enamel after careful carve. In the long-term clinical observation, 5 of the 206 veneers were fractured or fell off. This porcelain laminate veneers fabricated from the heat pressed IPS e.max Press ingots include the following advantages, such as simple operating procedure, high mechanical strength, very little dental tissue was ground off and nice aesthetic effect. Ultra-thin veneers are especially suitable for aesthetic practice to dental fluorosis, light tetracycline and natural worn teeth.

  10. Four chemical methods of porcelain conditioning and their influence over bond strength and surface integrity

    PubMed Central

    Stella, João Paulo Fragomeni; Oliveira, Andrea Becker; Nojima, Lincoln Issamu; Marquezan, Mariana

    2015-01-01

    OBJECTIVE: To assess four different chemical surface conditioning methods for ceramic material before bracket bonding, and their impact on shear bond strength and surface integrity at debonding. METHODS: Four experimental groups (n = 13) were set up according to the ceramic conditioning method: G1 = 37% phosphoric acid etching followed by silane application; G2 = 37% liquid phosphoric acid etching, no rinsing, followed by silane application; G3 = 10% hydrofluoric acid etching alone; and G4 = 10% hydrofluoric acid etching followed by silane application. After surface conditioning, metal brackets were bonded to porcelain by means of the Transbond XP system (3M Unitek). Samples were submitted to shear bond strength tests in a universal testing machine and the surfaces were later assessed with a microscope under 8 X magnification. ANOVA/Tukey tests were performed to establish the difference between groups (α= 5%). RESULTS: The highest shear bond strength values were found in groups G3 and G4 (22.01 ± 2.15 MPa and 22.83 ± 3.32 Mpa, respectively), followed by G1 (16.42 ± 3.61 MPa) and G2 (9.29 ± 1.95 MPa). As regards surface evaluation after bracket debonding, the use of liquid phosphoric acid followed by silane application (G2) produced the least damage to porcelain. When hydrofluoric acid and silane were applied, the risk of ceramic fracture increased. CONCLUSIONS: Acceptable levels of bond strength for clinical use were reached by all methods tested; however, liquid phosphoric acid etching followed by silane application (G2) resulted in the least damage to the ceramic surface. PMID:26352845

  11. Metal-ceramic bond strength between a feldspathic porcelain and a Co-Cr alloy fabricated with Direct Metal Laser Sintering technique

    PubMed Central

    Spyropoulos, Konstantinos

    2018-01-01

    PURPOSE The aim of the present study was to record the metal-ceramic bond strength of a feldspathic dental porcelain and a Co-Cr alloy, using the Direct Metal Laser Sintering technique (DMLS) for the fabrication of metal substrates. MATERIALS AND METHODS Ten metal substrates were fabricated with powder of a dental Co-Cr alloy using DMLS technique (test group) in dimensions according to ISO 9693. Another ten substrates were fabricated with a casing dental Co-Cr alloy using classic casting technique (control group) for comparison. Another three substrates were fabricated using each technique to record the Modulus of Elasticity (E) of the used alloys. All substrates were examined to record external and internal porosity. Feldspathic porcelain was applied on the substrates. Specimens were tested using the three-point bending test. The failure mode was determined using optical and scanning electron microscopy. The statistical analysis was performed using t-test. RESULTS Substrates prepared using DMLS technique did not show internal porosity as compared to those produced using the casting technique. The E of control and test group was 222 ± 5.13 GPa and 227 ± 3 GPa, respectively. The bond strength was 51.87 ± 7.50 MPa for test group and 54.60 ± 6.20 MPa for control group. No statistically significant differences between the two groups were recorded. The mode of failure was mainly cohesive for all specimens. CONCLUSION Specimens produced by the DMLS technique cover the lowest acceptable metal-ceramic bond strength of 25 MPa specified in ISO 9693 and present satisfactory bond strength for clinical use. PMID:29503711

  12. Effectiveness and stability of silane coupling agent incorporated in 'universal' adhesives.

    PubMed

    Yoshihara, Kumiko; Nagaoka, Noriyuki; Sonoda, Akinari; Maruo, Yukinori; Makita, Yoji; Okihara, Takumi; Irie, Masao; Yoshida, Yasuhiro; Van Meerbeek, Bart

    2016-10-01

    For bonding indirect restorations, some 'universal' adhesives incorporate a silane coupling agent to chemically bond to glass-rich ceramics so that a separate ceramic primer is claimed to be no longer needed. With this work, we investigated the effectiveness/stability of the silane coupling function of the silanecontaining experimentally prepared adhesives and Scotchbond Universal (3MESPE). Experimental adhesives consisted of Scotchbond Universal and the silane-free Clearfil S3 ND Quick (Kuraray Noritake) mixed with Clearfil Porcelain Bond Activator (Kuraray Noritake) and the two adhesives to which γ-methacryloxypropyltrimethoxysilane (γ-MPTS) was added. Shear bond strength was measured onto silica-glass plates; the adhesive formulations were analyzed using fourier transform infrared spectroscopy (FTIR) and 13C nuclear magnetic resonance (NMR). In addition, shear bond strength onto CAD-CAM composite blocks was measured without and after thermo-cycling ageing. A significantly higher bond strength was recorded when Clearfil Porcelain Bond Activator was freshly mixed with the adhesive. Likewise, the experimental adhesives, to which γ-MPTS was added, revealed a significantly higher bond strength, but only when the adhesive was applied immediately after mixing; delayed application resulted in a significantly lower bond strength. FTIR and (13)C NMR revealed hydrolysis and dehydration condensation to progress with the time after γ-MPTS was mixed with the two adhesives. After thermo-cycling, the bond strength onto CAD-CAM composite blocks remained stable only for the two adhesives with which Clearfil Porcelain Bond Activator was mixed. Only the silane coupling effect of freshly prepared silanecontaining adhesives was effective. Clinically, the use of a separate silane primer or silane freshly mixed with the adhesive remains recommended to bond glass-rich ceramics. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  13. An Outbreak of Norovirus Infection from Shellfish Soup Due to Unforeseen Insufficient Heating During Preparation.

    PubMed

    Lunestad, Bjørn Tore; Maage, Amund; Roiha, Irja Sunde; Myrmel, Mette; Svanevik, Cecilie Smith; Duinker, Arne

    2016-12-01

    Norovirus causes large outbreaks involving all age groups and are considered the most common cause of infectious foodborne diseases worldwide. The aim of this study was to describe a norovirus outbreak connected to insufficient heat treatment during preparation of a shellfish soup in serving portions, during a company Christmas celebration in Norway, December 2013. A questionnaire sent to the employees, showed that 67 % (n = 43) of the celebration participants, reported gastrointestinal symptoms including stomach pain, vomiting, diarrhoea and light fever in the period between 24 and 48 h post celebration. Several dishes were served, including shellfish soup made with carpet shell clams (Tapes rhomboides) in porcelain cups. Consuming this soup, was the only significant risk factor for infection. Norovirus GI and GII were detected in the remaining raw shellfish. To mimic the time and temperature obtained during bivalve soup preparation, raw chopped shellfish tissue and raw cepa onion were added in porcelain cups tempered to 20 °C. To each of these cups, boiling soup base was added. The temperature in the shellfish tissue was continuously recorded, and showed a maximum of 49 °C in the period between 3 and 7 min after adding the boiling soup base. After 1 h the temperature was 30 °C. This time and temperature combination was obviously not sufficient for inactivation of norovirus present in the shellfish tissue. In conclusion, the heat-absorbing capacity of cold ingredients, utensils and table wear porcelain should not be underestimated during food production. Consumers who want to avoid eating raw shellfish, should not assume that the shellfish tissue in preparation as described in our study is adequately heat treated.

  14. The effect of ZnO nanoparticle coating on the frictional resistance between orthodontic wires and ceramic brackets

    PubMed Central

    Behroozian, Ahmad; Kachoei, Mojgan; Khatamian, Masumeh; Divband, Baharak

    2016-01-01

    Background. Any decrease in friction between orthodontic wire and bracket can accelerate tooth movement in the sliding technique and result in better control of anchorage. This study was carried out to evaluate frictional forces by coating orthodontic wires and porcelain brackets with zinc oxide nanoparticles (ZnO). Methods. In this in vitro study, we evaluated a combination of 120 samples of 0.019×0.025 stainless steel (SS) orthodonticwires and 22 mil system edgewise porcelain brackets with and without spherical zinc oxide nanoparticles. Spherical ZnOnanoparticles were deposited on wires and brackets by immersing them in ethanol solution and SEM (scanning electronmicroscope) evaluation confirmed the presence of the ZnO coating. The frictional forces were calculated between the wiresand brackets in four groups: group ZZ (coated wire and bracket), group OO (uncoated wire and bracket), group ZO (coatedwire and uncoated bracket) and group OZ (uncoated wire and coated bracket). Kolmogorov-Smirnov, Mann-Whitney andKruskal-Wallis tests were used for data analysis. Results. The frictional force in ZZ (3.07±0.4 N) was the highest (P <0.05), and OZ (2.18±0.5 N) had the lowest amount of friction (P <0.05) among the groups. There was no significant difference in frictional forces between the ZO and OO groups (2.65±0.2 and 2.70±0.2 N, respectively). Conclusion. Coating of porcelain bracket surfaces with ZnO nanoparticles can decrease friction in the sliding technique,and wire coating combined with bracket coating is not recommended due to its effect on friction. PMID:27429727

  15. A comparison of two soldering techniques on the misfit of bar-retained implant-supported overdentures.

    PubMed

    Alvarez, Angel; Lafita, Pedro; de Llanos, Hector; Gago, Angel; Brizuela, Aritza; Ellacuria, Joseba J

    2014-02-01

    This study was conducted to measure and compare the effect of the soldering method (torch soldering or ceramic furnace soldering) used for soldering bars to bar-retained, implant-supported overdentures on the fit between the bar gold cylinder and implant transgingival abutment. Thirty-two overdenture implant bars were manufactured and screw retained into two Bränemark implants, which were attached to a cow rib. The bars were randomly distributed in two groups: a torch-soldering group and a porcelain-furnace soldering group. Then all bars were cut and soldered using a torch and a ceramic furnace. The fit between the bar gold cylinders and implant transgingival abutments was measured with a light microscope on the opposite side to the screw tightening side before and after the bar soldering procedure. The data obtained were statistically processed for paired and independent data. The average misfit for all bars before soldering was 33.83 to 54.04 μm. After cutting and soldering the bars, the misfit increased up to a range of 71.74 to 78.79 μm. Both before and after the soldering procedure, the bars soldered using a torch showed a higher misfit when compared to the bars soldered using a porcelain furnace. After the soldering procedure, the misfit was slightly lower on the left side of the bars, which had been soldered using a ceramic furnace. According to our data, the soldering of bars using the torch or furnace oven soldering techniques does not improve the misfit of one-piece cast bars on two implants. The lower misfit was obtained using the porcelain furnace soldering technique. © 2013 by the American College of Prosthodontists.

  16. Effect of the microstructure on the lifetime of dental ceramics.

    PubMed

    Borba, Márcia; de Araújo, Maico D; Fukushima, Karen A; Yoshimura, Humberto N; Cesar, Paulo F; Griggs, Jason A; Della Bona, Alvaro

    2011-07-01

    To evaluate the effect of the microstructure on the Weibull and slow crack growth (SCG) parameters and on the lifetime of three ceramics used as framework materials for fixed partial dentures (FPDs) (YZ - Vita In-Ceram YZ; IZ - Vita In-Ceram Zirconia; AL - Vita In-Ceram AL) and of two veneering porcelains (VM7 and VM9). Bar-shaped specimens were fabricated according to the manufacturer's instructions. Specimens were tested in three-point flexure in 37°C artificial saliva. Weibull analysis (n=30) and a constant stress-rate test (n=10) were used to determine the Weibull modulus (m) and SCG coefficient (n), respectively. Microstructural and fractographic analyzes were performed using SEM. ANOVA and Tukey's test (α=0.05) were used to statistically analyze data obtained with both microstructural and fractographic analyzes. YZ and AL presented high crystalline content and low porosity (0.1-0.2%). YZ had the highest characteristic strength (σ(0)) value (911MPa) followed by AL (488MPa) and IZ (423MPa). Lower σ(0) values were observed for the porcelains (68-75MPa). Except for IZ and VM7, m values were similar among the ceramic materials. Higher n values were found for YZ (76) and AL (72), followed by IZ (54) and the veneering materials (36-44). Lifetime predictions showed that YZ was the material with the best mechanical performance. The size of the critical flaw was similar among the framework materials (34-48μm) and among the porcelains (75-86μm). The microstructure influenced the mechanical and SCG behavior of the studied materials and, consequently, the lifetime predictions. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  17. Influence of tooth brushing on adhesion strength of orthodontic brackets bonded to porcelain.

    PubMed

    Durgesh, Bangalore H; Alhijji, Saleh; Hashem, Mohamed I; Al Kheraif, AbdulAziz A; Durgesh, Pavithra; Elsharawy, Mohamed; Vallittu, Pekka K

    2016-09-28

    Adhesive resin composite, which is used to bond orthodontic bracket to tooth surface is exposed to the influence of wear by tooth brushing and wear may influence loosening of the bracket. The aim of this study was to evaluate in vitro the effect of tooth brushing on the adhesion strength of orthodontic brackets bonded to surface treated porcelain. A total of 90 glazed porcelain fused to metal facets (PFM) were randomly assigned into 3 groups according to the surface treatment to be received. Group 1 was conditioned with hydrofluoric acid (HF), group 2 conditioned with grit-blasting (GB) and group 3 conditioned with tribochemical silica coating (RC). The groups were evaluated for surface roughness (Ra) before and after surface treatment. Next, 15 samples from each group were subjected to brushing and remaining 15 samples served as the baseline (n=15). Adhesion strength (shear bond strength)was recorded using a universal testing machine. Data collected were analyzed by ANOVA and Tukey's multiple comparison post hoc analysis. Tooth brushing decreased the bond strength in all groups. The highest adhesion strength (baseline and after brushing) was observed in group 3 (26.8 ± 1.77 MPa and 23.57 ± 1.02 MPa) and the lowest was found in group 1 (9.6 ± 1.5 MPa and 5.87 ± 0.77 MPa). Group 3 specimens exhibited the highest Ra (1.24 ± 0.08). It was found that tooth brushing of the exposed adhesive resin composite at the bracket-bonding substrate interface lowers the bonding strength regardless of the surface treatment of the substrate.

  18. 40 CFR 466.35 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Pretreatment standards for new sources. 466.35 Section 466.35 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Aluminum Basis Material Subcategory § 466...

  19. 40 CFR 466.41-466.42 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false [Reserved] 466.41-466.42 Section 466.41-466.42 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Copper Basis Material Subcategory §§ 466.41...

  20. 40 CFR 466.41-466.42 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false [Reserved] 466.41-466.42 Section 466.41-466.42 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Copper Basis Material Subcategory §§ 466.41...

  1. 40 CFR 466.43 - New source performance standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false New source performance standards. 466.43 Section 466.43 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Copper Basis Material Subcategory § 466.43...

  2. 40 CFR 466.43 - New source performance standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards. 466.43 Section 466.43 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Copper Basis Material Subcategory § 466.43...

  3. 40 CFR 466.23 - New source performance standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards. 466.23 Section 466.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Cast Iron Basis Material Subcategory § 466...

  4. 40 CFR 466.10 - Applicability; description of the steel basis material.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... steel basis material. 466.10 Section 466.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) PORCELAIN ENAMELING POINT SOURCE CATEGORY Steel Basis Material Subcategory § 466.10 Applicability; description of the steel basis material. This subpart...

  5. 40 CFR 466.10 - Applicability; description of the steel basis material.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... steel basis material. 466.10 Section 466.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Steel Basis Material Subcategory § 466.10 Applicability; description of the steel basis material. This subpart applies to...

  6. 40 CFR 466.10 - Applicability; description of the steel basis material.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... steel basis material. 466.10 Section 466.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) PORCELAIN ENAMELING POINT SOURCE CATEGORY Steel Basis Material Subcategory § 466.10 Applicability; description of the steel basis material. This subpart...

  7. 40 CFR 466.10 - Applicability; description of the steel basis material.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... steel basis material. 466.10 Section 466.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) PORCELAIN ENAMELING POINT SOURCE CATEGORY Steel Basis Material Subcategory § 466.10 Applicability; description of the steel basis material. This subpart...

  8. 40 CFR 466.10 - Applicability; description of the steel basis material.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... steel basis material. 466.10 Section 466.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Steel Basis Material Subcategory § 466.10 Applicability; description of the steel basis material. This subpart applies to...

  9. Environmental and human health assessment of life cycle of nanoTiO2 functionalized porcelain stoneware tile.

    PubMed

    Pini, Martina; Bondioli, Federica; Montecchi, Rita; Neri, Paolo; Ferrari, Anna Maria

    2017-01-15

    Recently, there has been a rise in the interest in nanotechnology due to its enormous potential for the development of new products and applications with higher performance and new functionalities. However, while nanotechnology might revolutionize a number of industrial and consumer sectors, there are uncertainties and knowledge gaps regarding toxicological effects of this emerging science. The goal of this research concerns the implementation into Life Cycle Assessment (LCA) of preliminary frameworks developed to evaluate human toxicity and exposure factors related to the potential nanoparticle releases that could occur during the life cycle steps of a functionalized building material. The present LCA case study examines the ecodesign of nanoTiO 2 functionalized porcelain stoneware tile production. The aim of this investigation is to manufacture new eco-friendly products in order to protect human health and ecosystem quality and to offer the market, materials with higher technological properties obtained by the addition of specific nanomaterials. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Research on corrosion mechanism of suspension insulator steel foot of direct current system and measures for corrosion inhibition

    NASA Astrophysics Data System (ADS)

    Chen, He; Yang, Yueguang; Su, Guolei; Wang, Xiaoqing; Zhang, Hourong; Sun, Xiaoyu; Fan, Youping

    2017-09-01

    There are increasingly serious electrocorrosion phenomena on insulator hardware caused by direct current transmission due to the wide-range popularization of extra high voltage direct current transmission engineering in our country. Steel foot corrosion is the main corrosion for insulators on positive polarity side of transmission lines. On one hand, the corrosion leads to the tapering off of steel foot diameter, having a direct influence on mechanical property of insulators; on the other hand, in condition of corrosion on steel foot wrapped in porcelain ware, the volume of the corrosion product is at least 50% more than that of the original steel foot, leading to bursting of porcelain ware, threatening safe operation of transmission lines. Therefore, it is necessary to conduct research on the phenomenon and propose feasible measures for corrosion inhibition. Starting with the corrosion mechanism, this article proposes two measures for corrosion inhibition, and verifies the inhibition effect in laboratory conditions, providing reference for application in engineering.

  11. [Interface compatibility between tooth-like yttria-stabilized tetragonal zirconia polycrystal by adding rare-earth oxide and Vita VM9 veneering porcelain].

    PubMed

    Gao, Yan; Zhang, Fu-qiang; He, Fan

    2011-10-01

    To evaluate the interface compatibility between tooth-like yttria-stabilized tetragonal zirconia polycrystal(Y-TZP) by adding rare-earth oxide and Vita VM9 veneering porcelain. Six kinds(S1,S2,S3,S4,S5,S6) of tooth-like yttria stabilized tetragonal zirconia polycrystal were made by introducing internal colorating technology to detect the thermal shock resistance and interface bonding strength with Vita VM9 Bsaedentin. Statistical analysis was performed using SAS6.12 software package. There was no gap between the layers via hot shocking test.The shear bonding strength between Y-TZP and VitaVM9 was higher and the value was (36.03±3.82) to (37.98±4.89) MPa. By adding rare-earth oxide to yttria-stabilized tetragonal zirconia polycrystal ,better compatibility between the layer (TZP and Vita VM9) can be formed which is of better interface integrate and available for clinical applications.

  12. [The ultrastructure and activities of free radical scavenger in discolored gingiva adjacent to porcelain fused to metal crowns].

    PubMed

    Zhang, Zhong-ti; Yan, Lu; Zhong, Ming; Yang, Xiao-dong; Ai, Hong-jun

    2007-04-01

    This study was designed to study the discolored gingiva adjacent to porcelain fused to metal (PFM) crowns in terms of ultrastructure , SOD and GSH activities in 40 cases. The discolored gingival ultrastructures were observed and metal X-ray energy level was analyzed;The activities of SOD and GSH were measured and compared with normal control by student's t test and one-way ANOVA with SPSS10.0 software package. The discolored gingival ultrastructure had changes compared with the normal gingiva. Nickel and chromium were not found in the particles through X-ray energy machine within the discolored gingiva adjacent to PFM crown. The activities of SOD and GSH in discolored gingiva were significantly different from control(P<0.05) and the values at 6 to 18 months were significantly different from those at other times. The ultrastructure underwent changes in discolored gingiva after PFM restoration; the activity of SOD and GSH in discolored gingiva changed to result in apoptosis, and discoloration.

  13. The effect of repeated firings on the color change and surface roughness of dental ceramics

    PubMed Central

    Yılmaz, Kerem; Ozturk, Caner

    2014-01-01

    PURPOSE The color of the ceramic restorations is affected by various factors such as brand, thickness of the layered the ceramic, condensation techniques, smoothness of surface, number of firings, firing temperature and thickness of dentin. The aim of this study was to evaluate the color change and surface roughness in dental porcelain with different thicknesses during repeated firings. MATERIALS AND METHODS Disc-shaped (N=21) metal-ceramic samples (IPS Classic; Ivoclar Vivadent; Shaar, Liechtenstein) with different thickness were exposed to repeated firings. Color measurement of the samples was made using a colorimeter and profilometer was used to determine surface roughness. ANOVA and Tukey tests with repeated measurements were used for statistical analysis. RESULTS The total thickness of the ceramics which is less than 2 mm significantly have detrimental effect on the surface properties and color of porcelains during firings (P<.05). CONCLUSION Repeated firings have effects on the color change and surface roughness of the dental ceramics and should be avoided. PMID:25177475

  14. Fractographic analysis of anterior bilayered ceramic crowns that failed by veneer chipping.

    PubMed

    Du, Qian; Swain, Michael V; Zhao, Ke

    2014-05-01

    To fractographically analyze the reasons for the chipping of veneering porcelain in clinically failed anterior lithium disilicate glass-ceramic (LDG) and glass-infi ltrated alumina (GIA) crowns. Five anterior bilayered ceramic crowns with clinical veneer chipping failure were retrieved, of which three were LDG crowns and two were GIA crowns. The fractured surfaces of the failed restorations were examined using stereomicroscopy and scanning electron microscopy (SEM). The principles of fractography were used to identify the location and dimensions of the critical crack and to estimate the stress at failure. All five anterior crowns failed by cohesive failure within the veneer on the labial surface. Fractography showed that the critical crack initiated at the incisal contact area and propagated gingivally. The estimated stresses at failure for veneer chipping were lower than the characteristic strength of the veneer materials. Within the limitations of this in-vivo study, the contact damage, fatigue, and processing fl aws within the veneer are important reasons leading to chipping of veneering porcelain in anterior LDG and GIA crowns.

  15. Development of porcelain enamel passive thermal control coatings

    NASA Technical Reports Server (NTRS)

    Levin, H.; Lent, W. E.; Buettner, D. H.

    1973-01-01

    A white porcelain enamel coating was developed for application to high temperature metallic alloy substrates on spacecraft. The coating consists of an optically opacifying zirconia pigment, a lithia-zirconia-silica frit, and an inorganic pigment dispersant. The coating is fired at 1000 to 1150 C to form the enamel. The coating has a solar absorptance of 0.22 and a total normal emittance of 0.82 for a 0.017 cm thick coating. The coating exhibits excellent adhesion, cleanability, and integrity and is thermal shock resistant to 900 C. Capability to coat large panels has been demonstrated by successful coating of 30 cm x 30 cm Hastelloy X alloy panels. Preliminary development of low temperature enamels for application to aluminum and titanium alloy substrates was initiated. It was determined that both leaded and leadless frits were feasible when applied with appropriate mill fluxes. Indications were that opacification could be achieved at firing temperatures below 540 C for extended periods of time.

  16. [Measurement of chromaticity of five hued zirconia].

    PubMed

    Wen, Ning; Shao, Long-quan; Yi, Yuan-fu; Deng, Bin; Liu, Hong-chen

    2009-05-01

    To determine the chroma value of sintered IL1-IL5 zirconia materials in comparison with the Vita In-Ceram YZ color shade. Five types of shading dental zirconia ceramics with color gradient were prepared by adding Fe2O3, CeO2, and Bi2O3 to the zirconia powder, and their chroma values were determined using a spectrophotometer and the color difference was calculated. The chroma value ranges were L: 67.76-77.78, a: -2.19-3.80, and b: 12.13-25.01. Slight deltaE was found between IL1 and LL1, IL2 and LL2, and IL3 and LL3. The deltaE between IL4 and LL4 could be compensated by veneering porcelain, whereas deltaL between IL5 and LL5 could not be compensated in this manner. Shading dental zirconia ceramics can be prepared by addition of metal oxides with color similar to the Vita In-Ceram YZ color shades to match that of the veneering porcelain in clinical practice.

  17. Cast titanium overlay denture for a geriatric patient with a reduced vertical dimension.

    PubMed

    Guttal, Satyabodh; Patil, Narendra P

    2005-12-01

    An older patient reporting to the dental surgery for his/her dental treatment is becoming a common occurrence. Improved oral hygiene has meant that teeth are retained for a longer time, along with the potential problems of attrition, decreased vertical dimension, temporomandibular joint discomfort/strain, and poor aesthetics. The case in question is that of a 65-year-old male patient who had severe attrition in the lower arch, temporomandibular joint pain and reduced vertical dimension. The maxillary arch had previously been restored with a fixed partial prosthesis. For restoration of the lower teeth, a removable cast titanium overlay denture was fabricated incorporating an increased vertical dimension. Porcelain facings were placed to restore the aesthetics of the anterior teeth. The titanium was cast in a semi-automatic electric arc, pressure type casting machine. A titanium overlay denture with porcelain facing on the anterior teeth may provide a means of restoring a patient's concerns regarding aesthetics and function.

  18. Hydrophobicity and leakage current statistics of polymeric insulators long-term exposed to coastal contamination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soerqvist, T.; Vlastos, A.E.

    1996-12-31

    The hydrophobicity of polymeric insulators is crucial for their performance. This paper reports the hydrophobicity and the peak leakage current statistics of one porcelain, two ethylene-propylene-diene monomer (EPDM) and four silicone rubber (SIR) commercially available insulators. The insulators have been energized with 130 kV rms phase-to-ground AC voltage under identical outdoor conditions for more than seven years. The results presented show that under wet and polluted conditions the hydrophilic EPDM rubber insulators develop high leakage currents and substantial arcing. During a typical salt-storm the arcing amplitude of the EPDM rubber insulators is at least twice as high as that ofmore » the porcelain insulator. The SIR insulators, on the other hand, preserve a high degree of hydrophobicity after more than seven years in service and maintain very low leakage currents. However, the results show that during heavy salt contaminated conditions a highly stressed SIR insulator can temporarily lose its hydrophobicity and thereby develop considerable surface arcing.« less

  19. 40 CFR 466.45 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Pretreatment standards for new sources. 466.45 Section 466.45 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Copper Basis Material Subcategory § 466.45...

  20. 40 CFR 466.45 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Pretreatment standards for new sources. 466.45 Section 466.45 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Copper Basis Material Subcategory § 466.45...

  1. Collection Development: Great Finds for Your Collectibles Shelf.

    ERIC Educational Resources Information Center

    Gross, Margarete

    1993-01-01

    Briefly reviews 41 books and periodicals about antiques and collectibles such as glassware, porcelain, dolls, buttons, ceramics, folk arts, furniture, jewelry, rugs, textiles, and woodenware. Books are arranged in the following topic areas: price guides; general surveys; out-of-print titles; trends; conservation and restoration; dealers; and…

  2. 40 CFR 466.25 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Pretreatment standards for new sources. 466.25 Section 466.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Cast Iron Basis Material Subcategory § 466...

  3. 40 CFR 466.24 - Pretreatment standards for existing sources.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... pretreatment standards the following equivalent mass standards are provided. (1) There shall be no discharge of... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Pretreatment standards for existing...) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) PORCELAIN ENAMELING POINT SOURCE CATEGORY Cast Iron Basis...

  4. 40 CFR 466.24 - Pretreatment standards for existing sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... pretreatment standards the following equivalent mass standards are provided. (1) There shall be no discharge of... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Pretreatment standards for existing...) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Cast Iron Basis Material...

  5. 40 CFR 466.24 - Pretreatment standards for existing sources.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... pretreatment standards the following equivalent mass standards are provided. (1) There shall be no discharge of... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Pretreatment standards for existing...) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) PORCELAIN ENAMELING POINT SOURCE CATEGORY Cast Iron Basis...

  6. 40 CFR 466.24 - Pretreatment standards for existing sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pretreatment standards the following equivalent mass standards are provided. (1) There shall be no discharge of... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Pretreatment standards for existing...) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Cast Iron Basis Material...

  7. 40 CFR 466.24 - Pretreatment standards for existing sources.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... pretreatment standards the following equivalent mass standards are provided. (1) There shall be no discharge of... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Pretreatment standards for existing...) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) PORCELAIN ENAMELING POINT SOURCE CATEGORY Cast Iron Basis...

  8. First Report of Garlic Rust Caused by Puccinia allii on Allium sativum in Minnesota

    USDA-ARS?s Scientific Manuscript database

    In July 2010, Allium sativum, cultivar German Extra Hardy Porcelain plants showing foliar symptoms typical of rust infection were brought to the Plant Disease Clinic at the University of Minnesota by a commercial grower from Fillmore county Minnesota. Infected leaves showed circular to oblong lesio...

  9. 40 CFR 63.4081 - Am I subject to this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... appliance parts and products; (2) Preparation of a coating for application (e.g., mixing in thinners and..., spray guns or dip tanks; (4) Application of porcelain enamel, powder coating, and asphalt interior...) Cleaning of equipment used in coating operations (e.g., application equipment, hangers, racks); (7) Storage...

  10. Refractory porcelain enamel passive-thermal-control coating for high-temperature superalloys

    NASA Technical Reports Server (NTRS)

    Levin, H.; Auker, B. H.; Gardos, M. N.

    1973-01-01

    Study was conducted to match thermal expansion coefficients thereby preventing enamels from cracking. Report discusses various enamel coatings that are applied to two different high-temperature superalloys. Study may be of interest to manufacturers of chemical equipment, furnaces, and metal components intended for high-temperature applications.

  11. 40 CFR 63.4081 - Am I subject to this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... source or group of stationary sources located within a contiguous area and under common control that... sources located within a contiguous area and under common control that is not a major source. (b) The..., spray guns or dip tanks; (4) Application of porcelain enamel, powder coating, and asphalt interior...

  12. 40 CFR 63.4081 - Am I subject to this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... source or group of stationary sources located within a contiguous area and under common control that... sources located within a contiguous area and under common control that is not a major source. (b) The..., spray guns or dip tanks; (4) Application of porcelain enamel, powder coating, and asphalt interior...

  13. 40 CFR 63.4081 - Am I subject to this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... source or group of stationary sources located within a contiguous area and under common control that... sources located within a contiguous area and under common control that is not a major source. (b) The..., spray guns or dip tanks; (4) Application of porcelain enamel, powder coating, and asphalt interior...

  14. 40 CFR 466.02 - General definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... EPA if the State does not have an approved program. (h) The term “precious metal” means gold, silver... STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY General Provisions § 466.02 General definitions. In addition to the definitions set forth in 40 CFR part 401, the following definitions apply to this part: (a...

  15. 40 CFR 466.20 - Applicability; description of the cast iron basis material subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Applicability; description of the cast... Cast Iron Basis Material Subcategory § 466.20 Applicability; description of the cast iron basis... of pollutants into publicly owned treatment works from porcelain enameling of cast iron basis...

  16. 77 FR 52313 - Notice of Scope Rulings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-29

    ..., 2012. A-570-506: Porcelain-On-Steel Cooking Ware from the People's Republic of China Requestor: The Coleman Company, Inc.; the stockpot locking lid of its Signature Series All-In-One Cooking System And Max Series is within the scope of the antidumping duty order; the stockpot cooking base of its Signature...

  17. 15. ELECTRICAL REACTOR SHELVES, CONSTRUCTED OF CONCRETE IN THE BASEMENT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. ELECTRICAL REACTOR SHELVES, CONSTRUCTED OF CONCRETE IN THE BASEMENT ALONG EAST WALL, WITH REACTOR PADS BEHIND FRAMED AND SCREENED CAGE, AND PORCELAIN-LINED CABLE DUCTS VISIBLE IN WALL NEAR FLOOR AT REAR - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  18. Instructional Resources. The Significance of Form: Ceramics.

    ERIC Educational Resources Information Center

    Zawatsky, Carole; And Others

    1989-01-01

    Presents four lesson plans designed to teach K-12 students about ceramics and the artists using the medium. Each lesson is centered around one ceramic piece: (1) "Wall Clock," by the Chantilly Porcelain Factory; (2) "Poppy Vase," by Adelaide Robineau; (3) "Laughing Eyes," by Pablo Picasso; and (4) "Ceramic Drum Jar," by Tsayutitsa. (GEA)

  19. Edo: Art in Japan 1615-1868. Teaching Program.

    ERIC Educational Resources Information Center

    Guth, Christine; Henderson, Anne; Hinish, Heidi; Moore, Barbara

    The Edo period in Japan (1615-1868) saw the flowering of many forms of cultural expression, colorful and boisterous, muted and restrained, that today is thought of as typically Japanese. These include kabuki and no drama, the tea ceremony, martial arts, woodblock prints, and porcelain. This culturally diverse and vibrant period gets its name from…

  20. Influence of ceramic surface texture on the wear of gold alloy and heat-pressed ceramics.

    PubMed

    Saiki, Osamu; Koizumi, Hiroyasu; Nogawa, Hiroshi; Hiraba, Haruto; Akazawa, Nobutaka; Matsumura, Hideo

    2014-01-01

    The purpose of this study was to evaluate the influence of ceramic surface texture on the wear of rounded rod specimens. Plate specimens were fabricated from zirconia (ZrO2), feldspathic porcelain, and lithium disilicate glass ceramics (LDG ceramics). Plate surfaces were either ground or polished. Rounded rod specimens with a 2.0-mm-diameter were fabricated from type 4 gold alloy and heat-pressed ceramics (HP ceramics). Wear testing was performed by means of a wear testing apparatus under 5,000 reciprocal strokes of the rod specimen with 5.9 N vertical loading. The results were statistically analyzed with a non-parametric procedure. The gold alloy showed the maximal height loss (90.0 µm) when the rod specimen was abraded with ground porcelain, whereas the HP ceramics exhibited maximal height loss (49.8 µm) when the rod specimen was abraded with ground zirconia. There was a strong correlation between height loss of the rod and surface roughness of the underlying plates, for both the gold alloy and HP ceramics.

  1. In vitro comparison of fracture load of implant-supported, zirconia-based, porcelain- and composite-layered restorations after artificial aging.

    PubMed

    Komine, Futoshi; Taguchi, Kohei; Fushiki, Ryosuke; Kamio, Shingo; Iwasaki, Taro; Matsumura, Hideo

    2014-01-01

    This study evaluated fracture load of single-tooth, implant-supported, zirconia-based, porcelain- and indirect composite-layered restorations after artificial aging. Forty-four zirconia-based molar restorations were fabricated on implant abutments and divided into four groups, namely, zirconia-based all-ceramic restorations (ZAC group) and three types of zirconia-based composite-layered restorations (ZIC-P, ZIC-E, and ZIC groups). Before layering an indirect composite material, the zirconia copings in the ZIC-P and ZIC-E groups were primed with Clearfil Photo Bond and Estenia Opaque Primer, respectively. All restorations were cemented on the abutments with glass-ionomer cement and then subjected to thermal cycling and cyclic loading. All specimens survived thermal cycling and cyclic loading. The fracture load of the ZIC-P group (2.72 kN) was not significantly different from that of the ZAC group (3.05 kN). The fracture load of the zirconia-based composite-layered restoration primed with Clearfil Photo Bond (ZIC-P) was comparable to that of the zirconia-based all-ceramic restoration (ZAC) after artificial aging.

  2. Compact vacuum insulation

    DOEpatents

    Benson, D.K.; Potter, T.F.

    1992-10-27

    Improved compact insulation panel is provided which is comprised of two adjacent metal sheets spaced close together with a plurality of spherical, or other discretely shaped, glass or ceramic beads optimally positioned between the sheets to provide support and maintain the spacing between the metal sheets when the gases there between are evacuated to form a vacuum. These spherical glass beads provide the maximum support while minimizing thermal conductance. In its preferred embodiment; these two metal sheets are textured with ribs or concave protrusions in conjunction with the glass beads to maximize the structural integrity of the panels while increasing the spacing between beads, thereby reducing the number of beads and the number of thermal conduction paths. Glass or porcelain-enameled liners in combination with the glass spacers and metal sidewalls effectively decrease thermal conductivity, and various laminates, including wood, porcelain-enameled metal, and others effectively increase the strength and insulation capabilities of the panels. Also, a metal web is provided to hold the spacers in place, and strategic grooves are shown to accommodate expansion and contraction or shaping of the panels. 35 figs.

  3. Compact vacuum insulation

    DOEpatents

    Benson, David K.; Potter, Thomas F.

    1992-01-01

    Improved compact insulation panel is provided which is comprised of two adjacent metal sheets spaced close together with a plurality of spherical, or other discretely shaped, glass or ceramic beads optimally positioned between the sheets to provide support and maintain the spacing between the metal sheets when the gases therebetween are evacuated to form a vacuum. These spherical glass beads provide the maximum support while minimizing thermal conductance. In its preferred embodiment; these two metal sheets are textured with ribs or concave protrusions in conjunction with the glass beads to maximize the structural integrity of the panels while increasing the spacing between beads, thereby reducing the number of beads and the number of thermal conduction paths. Glass or porcelain-enameled liners in combination with the glass spacers and metal sidewalls effectively decrease thermal conductivity, and variious laminates, including wood, porcelain-enameled metal, and others effectively increase the strength and insulation capabilities of the panels. Also, a metal web is provided to hold the spacers in place, and strategic grooves are shown to accommodate expansion and contraction or shaping of the panels.

  4. [Studies on sintering of dental porcelain. (Part 1) Binary system sintering of alumina and low fusing frit (author's transl)].

    PubMed

    Kuwayama, N; Kon, M

    1981-04-01

    Dental porcelains were made from frit and glass powder with electro fused alumina powder addition in the range from 20 to 60 wt% using sintering method at the temperature from 500 degree C to 1 000 degree C, and the effects of alumina content and firing temperature on firing processes of sintered composite were investigated. Shrinkage curves of the powder compacts varied with kind of frit and content of alumina. Particulary, powder compact with alumina addition in the range from 50 to 55% was found to have a remarkable influence for extention of firing temperature range. The densification of the powder compacts was considered to be accelerated by the dissolution of a small a mount of alumina particle into the frit and glass above 900 degree C. Expansion coefficient value of sintered composite of alumina and Pyrex glass powder gradually increased with increase of alumina content. Inversely, expansion coefficient of soda-lime-silica glass showed the minimum value at 40 wt% alumina content and then had a tendency of slight increases with increase of alumina content.

  5. Experimental and analytical studies on multiple tuned mass dampers for seismic protection of porcelain electrical equipment

    NASA Astrophysics Data System (ADS)

    Bai, Wen; Dai, Junwu; Zhou, Huimeng; Yang, Yongqiang; Ning, Xiaoqing

    2017-10-01

    Porcelain electrical equipment (PEE), such as current transformers, is critical to power supply systems, but its seismic performance during past earthquakes has not been satisfactory. This paper studies the seismic performance of two typical types of PEE and proposes a damping method for PEE based on multiple tuned mass dampers (MTMD). An MTMD damping device involving three mass units, named a triple tuned mass damper (TTMD), is designed and manufactured. Through shake table tests and finite element analysis, the dynamic characteristics of the PEE are studied and the effectiveness of the MTMD damping method is verified. The adverse influence of MTMD redundant mass to damping efficiency is studied and relevant equations are derived. MTMD robustness is verified through adjusting TTMD control frequencies. The damping effectiveness of TTMD, when the peak ground acceleration far exceeds the design value, is studied. Both shake table tests and finite element analysis indicate that MTMD is effective and robust in attenuating PEE seismic responses. TTMD remains effective when the PGA far exceeds the design value and when control deviations are considered.

  6. [An experimental study on the adaptation of three kinds of porcelain fused-to-metal restorations].

    PubMed

    Pei, Yan-Ping; Chen, Ji-Hua; Chang, Qing; Lin, Song-Shan; Zhang, He

    2009-04-01

    To compare the adaptation of porcelain fused-to-metal (PFM) restorations made from Ni-Cr alloy, precious alloy and galvanized forming copings after cementation and to provide a theory guidance for their application. Three kinds of crowns (Ni-Cr alloy, precious alloy and galvanized forming) were manufactured and cleaned by ultrasonic vibrate with alcoholic solution for 5 minutes, and cemented on their dies as their order. All the crowns were cemented by polycarboxylate zinc-cement and maintained 10 minutes. After coated in the center of methyl acrylic resins, all the samples were cut vertically along buccolingual direction. The cement thickness of PFM was measured by scanning electron microscope and the data were analyzed by multivariate ANOVA. No significant difference was found between the cement thickness of precious alloy crown and galvanized forming crown (P>0.05), while both of these two kinds of crown had significant differences in cement thickness with Ni-Cr crown (P<0.05). The adaptation of precious alloy crown and galvanized forming crown are superior to Ni-Cr crown.

  7. [Clinical evaluation of the effect of gold alloy and Ni-Cr alloy porcelain fused metal crown restorations].

    PubMed

    Sun, Wei-ge; Liu, Xiang-hui; Zhang, Ling; Zhang, Chun; Xie, Ming-yi; Zhou, Wen-juan

    2009-02-01

    To observe the clinical effect of gold alloy porcelain fused metal (PFM) crown restoration and Ni-Cr alloy PFM crown restoration. A total of 168 teeth from 48 patients were restored with gold alloy PFM crown. The other 48 patients, with a total of 179 teeth were restored with Ni-Cr alloy PFM crown. They were examined in integrality, retention, shade, cervical margin, and gingival health immediately, 6 months, one year, two years ,and three years after restoration. The date was analyzed by rank sum test using SPSS12.0 software package. The clinical effect of Ni-Cr alloy PFM crown was as good as gold alloy PFM crown when checked up after cementation at once. However, when they were examined 6 months, one year, two years ,and three years after restoration, the clinical effect of gold alloy PFM crown group was significantly better than that of Ni-Cr alloy PFM crown, P<0.05. The gold alloy PFM crown has better properties than Ni-Cr alloy PFM crown as a kind of long-term restoration, especially on the aspect of shade.

  8. Polysil shows promise. [Made by combining silica or ground rock (90%), an organic binder, and reinforcing fibers (10%)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1978-04-01

    A new synthetic, Polysil, promises to be half as costly to produce and even more suitable than porcelain as an outdoor insulating material for electric power equipment. Developed by the Electric Power Research Institute (EPRI), the polymer-silica compound has twice as much dielectric strength and half as much dielectric constant as porcelain. It also has design flexibility and is more resistant to impact. As a derivative of polymer concrete with six to eight times the strength of concrete, it has been successfully used for erosion control around dams and power plants. Production is simple and can be decentralized. Metal insertsmore » can be cast into the insulators rather than attaching separate end caps to lower costs and reduce contamination. Field testing on Polysil will continue for several years to test application for disconnect switches in residential areas; to use as a structural form in substations and eliminate insulators; to encase underground transmission conductors; and for circuit breakers and tower footings. Utilities will be looking for confirmation of polysil's durability and performance before making an extensive commitment.« less

  9. A 24-year retrospective study of bone growth after implant placement.

    PubMed

    Roberts, Ralph A

    2005-01-01

    This study quantifies the changes in bone height noted in the body of the edentulous mandibles when the load of the complete denture is born by an RA Ramus Frame Implant (Pacific Implant, Rio Dell, Calif). Eighty-three patients with implants were followed for 3 to 24 years. Pre- and postoperative panoramic films were taken and again at each succeeding 5-year follow-up. The results of the bone changes were gathered retrospectively and calculated. The data revealed a significant increase in bone height from 4.413 to 13 mm and statistically significant P values of <.0003 were determined. The growth of bone appears to be influenced by the design of the posterior feet, dominant chewing side, and a range of extreme atrophy from 5.9 mm to 15 mm. Also, the previously lost anatomical structures appear to repair, such as the luman of the mental foramen and the superior wall over the inferior alveolar canal. All mandibles were loaded postoperatively with an appliance having cutting bars and porcelain teeth or just porcelain teeth in both appliances.

  10. Complications and Clinical Considerations of the Implant-Retained Zirconia Complete-Arch Prosthesis with Various Opposing Dentitions.

    PubMed

    Gonzalez, Jorge; Triplett, Robert G

    To evaluate the performance of the implant-retained zirconia complete-arch prosthesis with various opposing dentitions. The 40 patients included in this retrospective case series study were treated with one or two implant-retained zirconia complete-arch prostheses (ZIRCAP) using the Zirkonzahn protocol. Prettau zirconia frames were created with strategic cutbacks in the structure to extend zirconia incisal coverage of the esthetic anterior sextants and complete monolithic zirconia in the molar areas; subsequent layers of porcelain were applied to nonfunctional and esthetic areas. Patients had three possible occlusal scenarios: (1) maxillary ZIRCAP and mandibular ZIRCAP, (2) maxillary ZIRCAP and mandibular natural dentition, and (3) maxillary ZIRCAP and mandibular conventional hybrid prosthesis. Complications were recorded during follow-up appointments 3, 6, and 12 months after definitive prosthesis delivery. The mean treatment observation period was 33 months. Eight prosthetic complications were noted for the 40 implant-retained zirconia complete-arch prostheses (18.18%), including six cases of minor porcelain chipping and two cases of debonding of the metal insert from the zirconia framework. Maxillary ZIRCAP opposing mandibular ZIRCAP and maxillary ZIRCAP opposing mandibular natural dentition occlusal scenarios presented the same complication ratio of 4. No complications were seen in the maxillary ZIRCAP opposing mandibular conventional hybrid prosthesis group, yet 16 complications were found as denture tooth fractures in 12 mandibular conventional hybrid prostheses (ratio of 0.75). The results indicate that the implant-retained zirconia complete-arch prosthesis offers acceptable performance for use as an alternative to the conventional titanium framework acrylic veneer prosthesis for complete edentulism with a lower incidence of prosthetic complications and fewer maintenance appointments. Chipping of veneering porcelain was the most common complication, but a low incidence was observed in this study. Acrylic denture teeth may represent the weakest link when restoring complete edentulism with a maxillary ZIRCAP and mandibular conventional hybrid prosthesis.

  11. Comparison of porcelain bond strength of different metal frameworks prepared by using conventional and recently introduced fabrication methods.

    PubMed

    Kaleli, Necati; Saraç, Duygu

    2017-07-01

    Most studies evaluating dental laser sintering systems have focused on the marginal accuracy of the restorations. However, the bond strength at the metal-ceramic interface is another important factor that affects the survival of restorations, and currently, few studies focus on this aspect. The purpose of this in vitro study was to compare the porcelain bond strength of cobalt-chromium (Co-Cr) metal frameworks prepared by using the conventional lost-wax technique, milling, direct metal laser sintering (DMLS), and laser cusing, a direct process powder-bed system. A total of 96 metal frameworks (n=24 in each group) were prepared by using conventional lost-wax (group C), milling (group M), DMLS (group LS), and direct process powder-bed (group LC) methods according to International Organization for Standardization standard ISO 9693-1. After porcelain application, a 3-point bend test was applied to each specimen by using a universal testing machine. Data were statistically analyzed using 1-way ANOVA and Tukey honest significant difference tests (α=.05). Failure types at the metal-ceramic interfaces were examined using stereomicroscopy. Additionally, 1 specimen from each group was prepared for scanning electron microscopy analysis to evaluate the surface topography of metal frameworks. The mean bond strength was 38.08 ±3.82 MPa for group C, 39.29 ±3.51 MPa for group M, 40.73 ±3.58 MPa for group LS, and 41.24 ±3.75 MPa for group LC. Statistically significant differences were observed among the 4 groups (P=.016). All groups, except for LS, exhibited adhesive and mixed type bond failure. Both of the laser sintering methods were found to be successful in terms of metal-ceramic bond strength. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Qualitative Assessment of Wear Resistance and Surface Hardness of Different Commercially Available Dental Porcelain: An in vitro Study.

    PubMed

    Singh, Abhishek; Nagpal, Abhishek; Pawah, Salil; Pathak, Chetan; Issar, Gaurav; Sharma, Pankaj

    2016-09-01

    In an attempt to minimize wear damage to the enamel of antagonist teeth, new low and medium fusing ceramic materials have been developed. Manufacturers usually claim that these ceramics are wear-friendly because of their lower hardness, lower concentrations of crystal phase, and smaller crystal sizes. This study aimed to quantitatively analyze the wear strength of various commercially available dental porcelain with tooth enamel as well as the surface hardness of these dental porcelain. The basic model was designed as a pin on plate arrangement. The tooth specimens were mounted on the stylus which was centered on the ceramic specimen in a wear testing machine. The dental ceramic specimen was centered in the metal die. A load of 40 N was applied at a rate of 80 cycles/minute for 15 minutes. In the current study, mean wear depth (Ra) value, volumetric loss, and surface hardness were obtained by standard quantification method and were statistically evaluated. Ceramco-3 was reported to be most abrasive for enamel; however, Duceram love significantly more abraded itself than the other two, Ceramco-3 and Vita Alpha, and generated the lowest loss of enamel. Also, same abrasive type of wear was revealed for all three variants of tested ceramics. Ceramco-3 was the most abrasive for enamel, while surface roughness (mean wear depth) of Duceram love was maximum and for Ceramco-3 it was minimum. The value of surface roughness for Vita Alpha was in between Duceram love and Ceramco-3. Nonetheless, the mean surface hardness of Duceram love was found to be least and maximum for Vita Alpha. In situations of dental wear and wasting tooth disease (Attrition/Abrasion), Duceram can be applied in lieu of Ceramco-3 so as to prevent worsening of existing dentition. However, in younger patients Vita Alpha would offer maximum durability due to its greater surface hardness.

  13. A comparative evaluation of bond strength of feldspathic porcelain to nickel-chromium alloy, when subjected to various surface treatments: An in vitro study

    PubMed Central

    Patel, Kavan A.; Mathur, Somil; Upadhyay, Snehal

    2015-01-01

    Purpose of the Study: The purpose was to evaluate the effect of various surface treatments and sandblasting with different particle size on the bond strength of feldspathic porcelain with predominantly base metal alloys, using a universal testing machine. Materials and Methods: Totally, 40 specimen of nickel-chromium alloy were prepared in an induction casting machine. The groups divided were as follows: Group I-sandblasted with 50 μ Al2O3, Group II-sandblasted with 110 μ Al2O3, Group III-sandblasted with 250 μ Al2O3 and Group IV-sandblasted with 250 μ Al2O3, followed by oxidation and again sandblasted with 250 μ Al2O3. The dimensions of each specimen were adjusted so as to maintain the thickness of ceramic at 1 mm. The specimen were loaded on the assembly of the universal testing machine, and a cross head speed of 0.5 mm/min was used to apply a compressive force at the junction of metal and feldspathic porcelain. The force application continued until adhesive fracture occurred, and the readings of the load applied to that particular specimen were recorded. Results: The means for shear bond strength for Group I, II, III and IV were found to be (226.92 ± 1.67), (233.16 ± 3.85), (337.81 ± 16.97) and (237.08 ± 4.33), respectively. Means of shear bond strength among the groups were compared using one-way analysis of variance test. Comparison between individual groups were made with Tukey's Honestly Significant Difference post-hoc test. Conclusion: Different particle size and surface treatment have an important role on the bond strength of ceramic-metal interface. Greater particle size demonstrated higher bond strength. PMID:26929487

  14. Plastic damage induced fracture behaviors of dental ceramic layer structures subjected to monotonic load.

    PubMed

    Wang, Raorao; Lu, Chenglin; Arola, Dwayne; Zhang, Dongsheng

    2013-08-01

    The aim of this study was to compare failure modes and fracture strength of ceramic structures using a combination of experimental and numerical methods. Twelve specimens with flat layer structures were fabricated from two types of ceramic systems (IPS e.max ceram/e.max press-CP and Vita VM9/Lava zirconia-VZ) and subjected to monotonic load to fracture with a tungsten carbide sphere. Digital image correlation (DIC) and fractography technology were used to analyze fracture behaviors of specimens. Numerical simulation was also applied to analyze the stress distribution in these two types of dental ceramics. Quasi-plastic damage occurred beneath the indenter in porcelain in all cases. In general, the fracture strength of VZ specimens was greater than that of CP specimens. The crack initiation loads of VZ and CP were determined as 958 ± 50 N and 724 ± 36 N, respectively. Cracks were induced by plastic damage and were subsequently driven by tensile stress at the elastic/plastic boundary and extended downward toward to the veneer/core interface from the observation of DIC at the specimen surface. Cracks penetrated into e.max press core, which led to a serious bulk fracture in CP crowns, while in VZ specimens, cracks were deflected and extended along the porcelain/zirconia core interface without penetration into the zirconia core. The rupture loads for VZ and CP ceramics were determined as 1150 ± 170 N and 857 ± 66 N, respectively. Quasi-plastic deformation (damage) is responsible for crack initiation within porcelain in both types of crowns. Due to the intrinsic mechanical properties, the fracture behaviors of these two types of ceramics are different. The zirconia core with high strength and high elastic modulus has better resistance to fracture than the e.max core. © 2013 by the American College of Prosthodontists.

  15. In vitro cytotoxicity of traditional versus contemporary dental ceramics.

    PubMed

    Messer, Regina L W; Lockwood, Petra E; Wataha, John C; Lewis, Jill B; Norris, Samuel; Bouillaguet, Serge

    2003-11-01

    The biocompatibility of new dental ceramics has not been assessed with the same scrutiny as has been applied to alloys and composites. Yet, the biocompatibility of ceramics is critical to the long-term success of dental prostheses because ceramics are in close contact with oral tissues for extended periods. Five dental ceramics (2 traditional feldspathic veneer porcelains [Vita Omega and Duceragold], 2 lithium disilicate pressable materials [Stylepress and Empress-2], and a pressable leucite-based material [Empress-1]) were tested for their ability to alter cellular mitochondrial dehydrogenase activity after fabrication using a tetrazolium assay, after aging for 2 weeks in a biologic solution and after post-aging polishing with either a fine diamond or diamond polishing paste. Cellular responses were compared with polytetrafluoroethylene controls (analysis of variance, Tukey pairwise post-hoc comparison, alpha=.05). The feldspathic porcelains caused only mild (<25% of controls) mitochondrial suppression regardless of aging or polishing. The pressable leucite-based material initially caused a 5% stimulation (not significant) of mitochondrial activity, which decreased significantly (P<.05) by 30% with aging to levels comparable to the feldspathic porcelains, and did not change with polishing. Both lithium disilicate materials caused an initial suppression of mitochondrial activity that decreased significantly with aging, but Empress-2 was severely cytotoxic initially (<20% of controls, P<.01), and became more cytotoxic again after polishing. Stylepress was less cytotoxic initially (85% of controls, not significant) and did not become cytotoxic again after polishing. Dental ceramics are not equivalent in their in vitro biologic effects, even within the same class of material, and biologic safety should not be assumed. Most ceramics caused only mild in vitro suppression of cell function to levels that would be acceptable on the basis of standards used to evaluate alloys and composites. However, 1 Li-disilicate material (Empress-2) exhibited cytotoxicity that would not be deemed biologically acceptable on the basis of prevailing empirical standards for dental alloys and composites.

  16. Interior of control house showing remains of controller. Moving the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior of control house showing remains of controller. Moving the handle rotated the vertical shaft and porcelain cams to engage various electrical switches and activate the lift mechanism. All electrical components have been removed. - Potomac Edison Company, Chesapeake & Ohio Canal Bridge, Spanning C & O Canal South of U.S. 11, Williamsport, Washington County, MD

  17. Architectural Panels

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Alliance Wall Corporation's Whyteboard, a porcelain enamel on steel panels wall board, owes its color stability to a KIAC engineering background study to identify potential technologies and manufacturers of equipment which could be used to detect surface flaws. One result of the data base search was the purchase of a spectrocolorimeter which enables the company to control some 250 standard colors, and match special colors.

  18. Kaolin

    USGS Publications Warehouse

    Virta, R.L.

    2011-01-01

    The article discusses the latest developments in the global kaolin industry, particularly in the U.S., as of June 2011. It claims that Georgia is the top producing state in the U.S., with a 94% share in total production. The other top producers include South Carolina, North Carolina and Florida. Kaolin is used in the manufacture of such products as electrical porcelain, pottery and sanitaryware.

  19. Mössbauer Studies in Chinese Archaeology: A Review

    NASA Astrophysics Data System (ADS)

    Hsia, Yuanfu; Huang, Hongbo

    2003-09-01

    The Mössbauer effect has been applied to a wide variety of objects related to Chinese archaeology. Besides ceramic artifacts, materials like porcelain, glazes, bronzes, ancient coins, ancient mineral drugs, and even fossils were studied. This article reviews these applications with particular emphasis on the study of the famous terracotta warriors and horses of the Qin Dynasty.

  20. Copper-silver ionization at a US hospital: interaction of treated drinking water with plumbing materials, aesthetics and other considerations

    EPA Science Inventory

    Tap water sampling and surface analysis of copper pipe/bathroom porcelain were performed to explore the fate of copper and silver during the first nine months of copper-silver ionization (CSI) applied to cold and hot water at a hospital in Cincinnati, Ohio. Ions dosed by CSI into...

  1. The Shock and Vibration Digest. Volume 18, Number 11

    DTIC Science & Technology

    1986-11-01

    instantaneous clearances for various conductor loadings and weather conditions. Composite insulators are now more widely used. They consists...ter under gunfire. However, their electrical and mechanical behaviors are mote complicated than those of analogous porcelain insulators because...mechanical considerations by discussing recent research papets. Tensile tests on composite insulators have shown that short-term tensile

  2. A Museum You Can Touch

    ERIC Educational Resources Information Center

    Pierpont, Katherine

    2005-01-01

    Walking into Keil Hileman's classroom at Monticello Trails Middle School in Shawnee, KS, is a visual feast for the eyes. There is a suit of armor, a 1796 Flintock Musket, a wood burning stove from 1907, a circa 1920 porcelain barber's chair, steamer trunks carried from far off lands, a butter churn, a 1930s wringer washing machine, chamber pots,…

  3. 75 FR 62144 - Porcelain-on-Steel Cooking Ware From China and Taiwan; Top-of-the-Stove Stainless Steel Cooking...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-07

    ... changes, if any, in the supply and demand conditions or business cycle for the Domestic Like Product that...-3088. Limited disclosure of business proprietary information (BPI) under an administrative protective... Merchandise. If you are a domestic producer, union/worker group, or trade/business association; import/export...

  4. 49 CFR 178.502 - Identification codes for packagings.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...” means a jerrican. (iv) “4” means a box. (v) “5” means a bag. (vi) “6” means a composite packaging. (vii... natural wood. (iv) “D” means plywood. (v) “F” means reconstituted wood. (vi) “G” means fiberboard. (vii... (other than steel or aluminum). (xi) “P” means glass, porcelain or stoneware. (3) A numeral indicating...

  5. 49 CFR 178.502 - Identification codes for packagings.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...” means a jerrican. (iv) “4” means a box. (v) “5” means a bag. (vi) “6” means a composite packaging. (vii... natural wood. (iv) “D” means plywood. (v) “F” means reconstituted wood. (vi) “G” means fiberboard. (vii... (other than steel or aluminum). (xi) “P” means glass, porcelain or stoneware. (3) A numeral indicating...

  6. 49 CFR 178.502 - Identification codes for packagings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...” means a jerrican. (iv) “4” means a box. (v) “5” means a bag. (vi) “6” means a composite packaging. (vii... natural wood. (iv) “D” means plywood. (v) “F” means reconstituted wood. (vi) “G” means fiberboard. (vii... (other than steel or aluminum). (xi) “P” means glass, porcelain or stoneware. (3) A numeral indicating...

  7. 49 CFR 178.502 - Identification codes for packagings.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...” means a jerrican. (iv) “4” means a box. (v) “5” means a bag. (vi) “6” means a composite packaging. (vii... natural wood. (iv) “D” means plywood. (v) “F” means reconstituted wood. (vi) “G” means fiberboard. (vii... (other than steel or aluminum). (xi) “P” means glass, porcelain or stoneware. (3) A numeral indicating...

  8. Dynamic hyperfiltration membranes for high-temperature spacecraft wash water recycle

    NASA Technical Reports Server (NTRS)

    Gaddis, J. L.; Brandon, C. A.

    1978-01-01

    The effect of operating parameters on the performance of the hyperfiltration membrane when operating on washwater was examined. The parameters were pressure, temperature, velocity, and concentration. Data taken included rejections of organic materials, ammonia, urea, and an assortment of ions. The membrane used was a dual layer, polyacrylic acid over zirconium oxide, deposited in situ on a porcelain ceramic substrate.

  9. 76 FR 7534 - Porcelain-on-Steel Cooking Ware from the People's Republic of China: Final Results of the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-10

    ... (``Act''). See Initiation of Five-Year (``Sunset'') Review, 75 FR 60731 (October 1, 2010) (``Sunset...)(3)(B) of the Act and 19 CFR 351.218(e)(1)(ii)(C)(2). As a result of this sunset review, the... Commerce. SUMMARY: On October 1, 2010, the Department of Commerce (``Department'') initiated a sunset...

  10. Study of alumosilicate porcelains: Sol-gel preparation, characterization and erosion evaluated by gravimetric method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bogdanoviciene, Irma; Jankeviciute, Audrone; Pinkas, Jiri

    2008-11-03

    In this paper, the sol-gel synthesis and characteristic properties of kalsilite-type alumosilicates (KAlSiO{sub 4} and K{sub 0.5}Na{sub 0.5}AlSiO{sub 4}) are reported. The polycrystalline powders were characterized by thermal analysis (TG/DTA), powder X-ray diffraction analysis (XRD) and scanning electron microscopy (SEM). Single-phase kalsilite oxides have been obtained after annealing precursor gels for 5 h in the temperature range of 750-850 deg. C. It was demonstrated that crystallinity of the samples slightly depends on the temperature of annealing. From the results obtained, it could be concluded that the KAlSiO{sub 4} solids are composed of the volumetric plate-like grains with no regular sizemore » (from 5 {mu}m to 30 {mu}m at 750 deg. C and around 5-50 {mu}m at 850 deg. C). Larger crystallites for mixed potassium-sodium kalsilite have formed (from 10 {mu}m to 80 {mu}m at 750 deg. C and >100 {mu}m at 850 deg. C) in comparison with potassium kalsilite samples). The erosion of obtained dental porcelain samples stored in saliva, beer and Coca-Cola was compared.« less

  11. Laser treatment of white China surface

    NASA Astrophysics Data System (ADS)

    Osvay, K.; Képíró, I.; Berkesi, O.

    2006-04-01

    The surface of gloss fired porcelain with and without raw glaze coating was radiated by a CO 2 laser working at 10.6 μm, a choice resulted from spectroscopic studies of suspensions made of China. The shine of the untreated sample was defined as the distribution of micro-droplets on the surface. The surface alterations due to laser heating were classified by the diameter of the completely melted surface, the ring of the surface at the threshold of melting, and the size of microscopic cracks. The diameter of the laser treated area was in the range of 3 mm, while the incident laser power and the duration of laser heating were varied between 1 and 10 W and 1-8 min, respectively. The different stages of surface modifications were attributed primarily to the irradiating laser power and proved to be rather insensitive to the duration of the treatment. We have found a range of parameters under which the white China surface coated with raw glaze and followed by laser induced melting exhibited very similar characteristics to the untreated porcelain. This technique seems prosperous for laser assisted reparation of small surface defects of unique China samples after the firing process.

  12. [Comparison of magnetic resonance imaging artifacts of five common dental materials].

    PubMed

    Xu, Yisheng; Yu, Risheng

    2015-06-01

    To compare five materials commonly used in dentistry, including three types of metals and two types of ceramics, by using different sequences of three magnetic resonance imaging (MRI) field strengths (0.35, 1.5, and 3.0 T). Three types of metals and two types of ceramics that were fabricated into the same size and thickness as an incisor crown were placed in a plastic tank filled with saline. The crowns were scanned using an magnetic resonance (MR) machine at 0.35, 1.5, and 3.0 T field strengths. The TlWI and T2WI images were obtained. The differences of various materials in different artifacts of field MR scans were determined. The zirconia crown presented no significant artifacts when scanned under the three types of MRI field strengths. The artifacts of casting ceramic were minimal. All dental precious metal alloys, nickel-chromium alloy dental porcelain, and cobalt-chromium ceramic alloy showed varying degrees of artifacts under the three MRI field strengths. Zirconia and casting ceramics present almost no or faint artifacts. By contrast, precious metal alloys, nickel-chromium alloy dental porcelain and cobalt-chromium ceramic alloy display MRI artifacts. The artifact area increase with increasing magnetic field.

  13. Zirconia in fixed prosthesis. A literature review

    PubMed Central

    Román-Rodríguez, Juan L.; Ferreiroa, Alberto; Solá-Ruíz, María F.; Fons-Font, Antonio

    2014-01-01

    Statement of problem: Evidence is limited on the efficacy of zirconia-based fixed dental prostheses. Objective: To carry out a literature review of the behavior of zirconium oxide dental restorations. Material and Methods: This literature review searched the Pubmed, Scopus, Medline and Cochrane Library databases using key search words “zirconium oxide,” “zirconia,” “non-metal restorations,” “ceramic oxides,” “veneering ceramic,” “zirconia-based fixed dental prostheses”. Both in vivo and in vitro studies into zirconia-based prosthodontic restoration behavior were included. Results: Clinical studies have revealed a high rate of fracture for porcelain-veneered zirconia-based restorations that varies between 6% and 15% over a 3- to 5-year period, while for ceramo-metallic restorations the fracture rate ranges between 4 and 10% over ten years. These results provoke uncertainty as to the long-term prognosis for this material in the oral medium. The cause of veneering porcelain fractures is unknown but hypothetically they could be associated with bond failure between the veneer material and the zirconia sub-structure. Key words:Veneering ceramic, zirconia-based ceramic restoration, crown, zirconia, tooth-supported fixed prosthesis. PMID:24596638

  14. Double-arterial cannulation for aortic valve replacement with porcelain aorta.

    PubMed

    De Paulis, Ruggero; Maselli, Daniele; Scaffa, Raffaele; Nardella, Saverio

    2009-10-01

    We describe a new technique of aortic valve replacement (AVR) in patients with porcelain aorta. Three patients (mean age 75 years) were treated. The cardiopulmonary bypass (CPB) was established after side-graft right axillary artery and direct femoral artery cannulation. Venous drainage was obtained by atrio-caval cannulation. The procedures were performed in mild hypothermia (30 degrees C). Cerebral perfusion was carried out by clamping the innominate artery and all epiaortic vessels. The aorta was endoclamped by a Foley balloon inserted into the isthmus. The aorta was then opened longitudinally for 10 cm to expose and replace the aortic valve. Near-infra-red spectroscopy (NIRS) and bilateral radial artery pressure were used to monitor effective cerebral perfusion. Operative mortality was absent. The mean time of CPB was 73 min. NIRS-derived tissue oxygenation was maintained above 55%. Postoperative course was uneventful. This technique has several advantages: first, the cannulation of right axillary and the common femoral artery allows simultaneous cerebral and systemic perfusion. Second, any form of cross-clamp is avoided and the aorta is occluded away from the epiaortic vessels. Third, there is an increased freedom to choose the best place for aortotomy.

  15. [Effect of silicon coating on bonding strength of ceramics and titanium].

    PubMed

    Zhou, Shu; Wang, Yu; Zhang, Fei-Min; Guang, Han-Bing

    2009-06-01

    This study investigated the effect of silicon coating (SiO2) by solution-gelatin (Sol-Gel) technology on bonding strength of titanium and ceramics. Sixteen pure titanium specimens with the size of 25 mm x 3 mm x 0.5 mm were divided into two groups (n=8), test group was silicon coated by Sol-Gel technology, the other one was control group. The middle area of the samples were veneered with Vita Titankeramik system, the phase composition of two specimens were characterized by X-ray diffraction (XRD). The bonding strength of titanium/porcelain was evaluated using three-point bending test. The interface of titanium and porcelain and fractured titanium surface were investigated by scanning electron microscope (SEM) with energy depressive spectrum (EDS). Contents of surface silicon increased after modification with silicon coated by Sol-Gel technology. The mean bonding strength of test group and control group were (37.768 +/- 0.777) MPa and (29.483 +/- 1.007) MPa. There was a statistically significant difference (P=0.000) between them. The bonded ceramic boundary of test group was wider than control group. Silicon coating by Sol-Gel technology was significant in improving bonding strength of titanium/Vita Titankeramik system.

  16. Edge chipping and flexural resistance of monolithic ceramics☆

    PubMed Central

    Zhang, Yu; Lee, James J.-W.; Srikanth, Ramanathan; Lawn, Brian R.

    2014-01-01

    Objective Test the hypothesis that monolithic ceramics can be developed with combined esthetics and superior fracture resistance to circumvent processing and performance drawbacks of traditional all-ceramic crowns and fixed-dental-prostheses consisting of a hard and strong core with an esthetic porcelain veneer. Specifically, to demonstrate that monolithic prostheses can be produced with a much reduced susceptibility to fracture. Methods Protocols were applied for quantifying resistance to chipping as well as resistance to flexural failure in two classes of dental ceramic, microstructurally-modified zirconias and lithium disilicate glass–ceramics. A sharp indenter was used to induce chips near the edges of flat-layer specimens, and the results compared with predictions from a critical load equation. The critical loads required to produce cementation surface failure in monolithic specimens bonded to dentin were computed from established flexural strength relations and the predictions validated with experimental data. Results Monolithic zirconias have superior chipping and flexural fracture resistance relative to their veneered counterparts. While they have superior esthetics, glass–ceramics exhibit lower strength but higher chip fracture resistance relative to porcelain-veneered zirconias. Significance The study suggests a promising future for new and improved monolithic ceramic restorations, with combined durability and acceptable esthetics. PMID:24139756

  17. Biofilm Formation on Different Materials Used in Oral Rehabilitation.

    PubMed

    Souza, Júlio C M; Mota, Raquel R C; Sordi, Mariane B; Passoni, Bernardo B; Benfatti, Cesar A M; Magini, Ricardo S

    2016-01-01

    The aim of this study was to evaluate the density and the morphological aspects of biofilms adhered to different materials applied in oral rehabilitation supported by dental implants. Sixty samples were divided into four groups: feldspar-based porcelain, CoCr alloy, commercially pure titanium grade IV and yttria-stabilized zirconia. Human saliva was diluted into BHI supplemented with sucrose to grow biofilms for 24 or 48 h. After this period, biofilm was removed by 1% protease treatment and then analyzed by spectrophotometry (absorbance), colony forming unit method (CFU.cm-2) and field-emission guns scanning electron microscopy (FEG-SEM). The highest values of absorbance and CFU.cm-2 were recorded on biofilms grown on CoCr alloys when compared to the other test materials for 24 or 48 h. Also, FEG-SEM images showed a high biofilm density on CoCr. There were no significant differences in absorbance and CFU.cm-2 between biofilms grown on zirconia, porcelain and titanium (p<0.05). Microbiological assays associated with microscopic analyses detected a higher accumulation of oral biofilms on CoCr-based materials than that on titanium or zirconia that are used for prosthetic structures.

  18. 49 CFR Appendix A to Part 172 - Office of Hazardous Materials Transportation Color Tolerance Charts and Tables

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... .3308 .2328 Dark 10.0P 4.0/10 12.00 .3306 .2162 1 Maximum chroma is not limited. 2 For the colors green and purple, the minimum saturation (chroma) limits for porcelain enamel on metal are lower than for most other surface coatings. Therefore, the minimum chroma limits of these two colors as displayed on...

  19. Impact of Gastric Acid Induced Surface Changes on Mechanical Behavior and Optical Characteristics of Dental Ceramics.

    PubMed

    Kulkarni, Aditi; Rothrock, James; Thompson, Jeffery

    2018-01-14

    To test the impact of exposure to artificial gastric acid combined with toothbrush abrasion on the properties of dental ceramics. Earlier research has indicated that immersion in artificial gastric acid has caused increased surface roughness of dental ceramics; however, the combined effects of acid immersion and toothbrush abrasion and the impact of increased surface roughness on mechanical strength and optical properties have not been studied. Three commercially available ceramics were chosen for this study: feldspathic porcelain, lithium disilicate glass-ceramic, and monolithic zirconium oxide. The specimens (10 × 1 mm discs) were cut, thermally treated as required, and polished. Each material was divided into four groups (n = 8 per group): control (no exposure), acid only, brush only, acid + brush. The specimens were immersed in artificial gastric acid (50 ml of 0.2% [w/v] sodium chloride in 0.7% [v/v] hydrochloric acid mixed with 0.16 g of pepsin powder, pH = 2) for 2 minutes and rinsed with deionized water for 2 minutes. The procedure was repeated 6 times/day × 9 days, and specimens were stored in deionized water at 37°C. Toothbrush abrasion was performed using an ISO/ADA design brushing machine for 100 cycles/day × 9 days. The acid + brush group received both treatments. Specimens were examined under SEM and an optical microscope for morphological changes. Color and translucency were measured using spectrophotometer CIELAB coordinates (L*, a*, b*). Surface gloss was measured using a gloss meter. Surface roughness was measured using a stylus profilometer. Biaxial flexural strength was measured using a mechanical testing machine. The data were analyzed by one-way ANOVA followed by Tukey's HSD post hoc test (p < 0.05). Statistically significant changes were found for color, gloss, and surface roughness for porcelain and e.max specimens. No statistically significant changes were found for any properties of zirconia specimens. The acid treatment affected the surface roughness, color, and gloss of porcelain and e.max ceramics. The changes in translucency and mechanical strength for all materials were not statistically significant. Zirconia ceramic showed resistance to all treatments. © 2018 by the American College of Prosthodontists.

  20. Quantitative crystalline silica exposure assessment for a historical cohort epidemiologic study in the German porcelain industry.

    PubMed

    Birk, Thomas; Guldner, Karlheinz; Mundt, Kenneth A; Dahmann, Dirk; Adams, Robert C; Parsons, William

    2010-09-01

    A time-dependent quantitative exposure assessment of silica exposure among nearly 18,000 German porcelain workers was conducted. Results will be used to evaluate exposure-response disease risks. Over 8000 historical industrial hygiene (IH) measurements with original sampling and analysis protocols from 1954-2006 were obtained from the German Berufs- genossenschaft der keramischen-und Glas-Industrie (BGGK) and used to construct a job exposure matrix (JEM). Early measurements from different devices were converted to modern gravimetric equivalent values. Conversion factors were derived from parallel historical measurements and new side-by-side measurements using historical and modern devices in laboratory dust tunnels and active workplace locations. Exposure values were summarized and smoothed using LOESS regression; estimates for early years were derived using backward extrapolation techniques. Employee work histories were merged with JEM values to determine cumulative crystalline silica exposures for cohort members. Average silica concentrations were derived for six primary similar exposure groups (SEGs) for 1938-2006. Over 40% of the cohort accumulated <0.5 mg; just over one-third accumulated >1 mg/m(3)-years. Nearly 5000 workers had cumulative crystalline silica estimates >1.5 mg/m(3)-years. Similar numbers of men and women fell into each cumulative exposure category, except for 1113 women and 1567 men in the highest category. Over half of those hired before 1960 accumulated >3 mg/m(3)-years crystalline silica compared with 4.9% of those hired after 1960. Among those ever working in the materials preparation area, half accumulated >3 mg/m(3)-year compared with 12% of those never working in this area. Quantitative respirable silica exposures were estimated for each member of this cohort, including employment periods for which sampling used now obsolete technologies. Although individual cumulative exposure estimates ranged from background to about 40 mg/m(3)-years, many of these estimates reflect long-term exposures near modern exposure limit values, allowing direct evaluation of lung cancer and silicosis risks near these limits without extrapolation. This quantitative exposure assessment is the largest to date in the porcelain industry.

  1. Probability of survival of implant-supported metal ceramic and CAD/CAM resin nanoceramic crowns.

    PubMed

    Bonfante, Estevam A; Suzuki, Marcelo; Lorenzoni, Fábio C; Sena, Lídia A; Hirata, Ronaldo; Bonfante, Gerson; Coelho, Paulo G

    2015-08-01

    To evaluate the probability of survival and failure modes of implant-supported resin nanoceramic relative to metal-ceramic crowns. Resin nanoceramic molar crowns (LU) (Lava Ultimate, 3M ESPE, USA) were milled and metal-ceramic (MC) (Co-Cr alloy, Wirobond C+, Bego, USA) with identical anatomy were fabricated (n=21). The metal coping and a burnout-resin veneer were created by CAD/CAM, using an abutment (Stealth-abutment, Bicon LLC, USA) and a milled crown from the LU group as models for porcelain hot-pressing (GC-Initial IQ-Press, GC, USA). Crowns were cemented, the implants (n=42, Bicon) embedded in acrylic-resin for mechanical testing, and subjected to single-load to fracture (SLF, n=3 each) for determination of step-stress profiles for accelerated-life testing in water (n=18 each). Weibull curves (50,000 cycles at 200N, 90% CI) were plotted. Weibull modulus (m) and characteristic strength (η) were calculated and a contour plot used (m versus η) for determining differences between groups. Fractography was performed in SEM and polarized-light microscopy. SLF mean values were 1871N (±54.03) for MC and 1748N (±50.71) for LU. Beta values were 0.11 for MC and 0.49 for LU. Weibull modulus was 9.56 and η=1038.8N for LU, and m=4.57 and η=945.42N for MC (p>0.10). Probability of survival (50,000 and 100,000 cycles at 200 and 300N) was 100% for LU and 99% for MC. Failures were cohesive within LU. In MC crowns, porcelain veneer fractures frequently extended to the supporting metal coping. Probability of survival was not different between crown materials, but failure modes differed. In load bearing regions, similar reliability should be expected for metal ceramics, known as the gold standard, and resin nanoceramic crowns over implants. Failure modes involving porcelain veneer fracture and delamination in MC crowns are less likely to be successfully repaired compared to cohesive failures in resin nanoceramic material. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  2. Effect of layered manufacturing techniques, alloy powders, and layer thickness on metal-ceramic bond strength.

    PubMed

    Ekren, Orhun; Ozkomur, Ahmet; Ucar, Yurdanur

    2018-03-01

    Direct metal laser sintering (DMLS) and direct metal laser melting (DMLM) have become popular for fabricating the metal frameworks of metal-ceramic restorations. How the type of layered manufacturing device, layer thickness, and alloy powder may affect the bond strength of ceramic to metal substructure is unclear. The purpose of this in vitro study was to evaluate the bond strength of dental porcelain to metal frameworks fabricated using different layered manufacturing techniques (DMLS and DMLM), Co-Cr alloy powders, and layer thicknesses and to evaluate whether a correlation exists between the bond strength and the number of ceramic remnants on the metal surface. A total of 75 bar-shaped metal specimens (n=15) were fabricated using either DMLS or DMLM. The powder alloys used were Keramit NP-S and EOS-Cobalt-Chrome SP-2 with layer thicknesses of 20 μm and 30 μm. After ceramic application, the metal-ceramic bond strength was evaluated with a 3-point-bend test. Three-way ANOVA followed by the Tukey honest significance difference test were used for statistical analysis (α=.05). De-bonding surface microstructure was observed with scanning electron microscopy. Energy dispersive spectroscopy analysis was conducted to evaluate the correlation between ceramic remnants on the metal surface and bond strength values. The mean bond strength value of DMLS was significantly higher than that of DMLM. While no statistically significant difference was found between layer thicknesses, alloy powders closely affected bond strength. Statistical comparisons revealed that the highest bond strength could be achieved with DMLS-Cobalt-Chrome SP2-20μm, and the lowest bond strength was observed in DMLS-Keramit NP-S-20μm (P≤.05). No correlation was found between porcelain remnants on the metal surface and bond strength values. The layered manufacturing device and the alloy powders evaluated in the current study closely affected the bond strength of dental porcelain to a metal framework. However, layer thickness did not affect the bond strength. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. [Effect of hydrofluoric acid etching time on the resin bond durability of glass ceramic].

    PubMed

    Meng, Xiang-feng; Zhou, Xiao-lu; Luo, Xiao-ping

    2010-05-01

    To analyze the effect of hydrofluoric acid (HFA) etching time on the resin bond durability of glass ceramic. Three groups of samples of machinable glass ceramic (ProCAD) were etched by 4.8% HFA for 0, 30 and 60 s respectively. The roughness parameters (Ra, Sm, S) and surface area of the samples, were measured with a 3D-laser scanning microscope. Then the ceramic surfaces were bonded with four resin cements (silane coupler/resin cement), which were Monobond S/Variolink II, Clearfil Ceramic Primer/Clearfil Esthetic Cement, GC Ceramic Primer/Linkmax HV, and Porcelain Liner M/SuperBond. The micro-bond strengths between the ceramic and the resin were tested at baseline and after the samples had been treated in 30000 thermal cycles. The Ra [(3.89+/-1.94), (12.53+/-0.80), (13.58+/-1.10) microm] and surface area [(7.81+/-2.96), (30.18+/-2.05), (34.16+/-1.97) mm2] of ceramic increased with the increase of HFA etching time. The thermal cycling test reduced the bond strength of all test groups. The bond strength of Monobond S/Variolink II group [(3.59+/-3.51), (16.18+/-2.62), (20.33+/-2.45) MPa] and Clearfil Ceramic Primer/Clearfil Esthetic Cement group [(4.74+/-2.08), (7.77+/-1.55), (13.45+/-3.75) MPa] increased with the increase of HFA etching time; 30 s HFA etching group of Porcelain Liner M/SuperBond had higher bond strength [(22.00+/-1.64) MPa] than its 0 s HFA etching group [(12.96+/-4.17) MPa], and no significant difference was found between the 30 s and 60 s HFA etching groups of Porcelain Liner M/SuperBond [(20.42+/-3.01) MPa]. HFA etching time had no effect on the bond strength of GC Ceramic Primer/Linkmax HV. HFA etching can improve the resin bond durability of glass ceramic, and the etching time is not only related to the change of ceramic surface roughness and area, but also to the characteristics of resins.

  4. Spectrophotometric evaluation of the influence of different backgrounds on the color of glass-infiltrated ceramic veneers.

    PubMed

    Charisis, Dimitrios; Koutayas, Spiridon-Oumvertos; Kamposiora, Photini; Doukoudakis, Asterios

    2006-08-01

    The purpose of this spectrophotometric study was to evaluate the influence of different color backgrounds on Vita In-Ceram (Vident) glass-infiltrated ceramic veneers. A total of 50 color background disks were fabricated from Vitadur Alpha 2M2 (n=30) and 5M1 (n=20) dentin porcelain (Vi-dent). Ceramic veneer disks were fabricated from In-Ceram Spinell (n=20) or In-Ceram Alumina (n=20) glass-infiltrated core veneered using Vitadur Alpha 2M2 dentin porcelain. In addition, 10 ceramic veneer disks were fabricated from feldspathic dentin porcelain Vitadur Alpha 2M2. The ceramic veneer specimens were bonded onto the color background specimens using dual-curing luting composite cement, creating the following groups (each n=10): S2M2 (Spinell/2M2), S5M1 (Spinell/5M1), A2M2 (Alumina/2M2), A5M1 (Alumina/5M1), and control (Vitadur Alpha/2M2). L*a*b* color coordinates were measured five times for each specimen using a Vita Easyshade (Vident) spectrophotometer. Mean color differences (deltaE) between each study group and the control group were: 3.79 for S2M2; 7.24 for S5M1; 5.86 for A2M2, and 7.32 for A5M1. Two-way ANOVA showed statistically significant differences in deltaE between all groups. However, a t test revealed that the statistically significant differences only existed between groups S2M2/S5M1, A2M2/A5M1, and S2M2/A2M2. The results suggest that vacuum infiltration with a translucent glass provides the Spinell and Alumina ceramic veneers with increased semi-translucency, which makes them highly influenced by discolored backgrounds. In-Ceram Spinell glass-infiltrated ceramic veneers could be considered as an alternative to conventional feldspathic veneers for the restoration of nondiscolored teeth. Although Spinell and Alumina ceramic veneers could enhance the final color establishment of discolored teeth, the results would not be clinically acceptable.

  5. Evaluation of the ability of Acinetobacter baumannii to form biofilms on six different biomedical relevant surfaces.

    PubMed

    Greene, C; Wu, J; Rickard, A H; Xi, C

    2016-10-01

    The human opportunistic pathogen, Acinetobacter baumannii, has the propensity to form biofilms and frequently cause medical device-related infections in hospitals. However, the physio-chemical properties of medical surfaces, in addition to bacterial surface properties, will affect colonization and biofilm development. The objective of this study was to compare the ability of A. baumannii to form biofilms on six different materials common to the hospital environment: glass, porcelain, stainless steel, rubber, polycarbonate plastic and polypropylene plastic. Biofilms were developed on material coupons in a CDC biofilm reactor. Biofilms were visualized and quantified using fluorescent staining and imaged using confocal laser scanning microscopy (CLSM) and by direct viable cell counts. Image analysis of CLSM stacks indicated that the mean biomass values for biofilms grown on glass, rubber, porcelain, polypropylene, stainless steel and polycarbonate were 0·04, 0·26, 0·62, 1·00, 2·08 and 2·70 μm(3) /μm(2) respectively. Polycarbonate developed statistically more biofilm mass than glass, rubber, porcelain and polypropylene. Viable cell counts data were in agreement with the CLSM-derived data. In conclusion, polycarbonate was the most accommodating surface for A. baumannii ATCC 17978 to form biofilms while glass was least favourable. Alternatives to polycarbonate for use in medical and dental devices may need to be considered. In the hospital environment, Acinetobacter baumannii is one of the most persistent and difficult to control opportunistic pathogens. The persistence of A. baumannii is due, in part, to its ability to colonize surfaces and form biofilms. This study demonstrates that A. baumannii can form biofilms on a variety of different surfaces and develops substantial biofilms on polycarbonate - a thermoplastic material that is often used in the construction of medical devices. The findings highlight the need to further study the in vitro compatibility of medical materials that could be colonized by A. baumannii and allow it to persist in hospital settings. © 2016 The Society for Applied Microbiology.

  6. Summaries of Research - Fiscal Year 1991.

    DTIC Science & Technology

    1992-05-01

    determine the cost effectiveness of Navy dental technicians applying occlusal sealants to teeth with incipient caries has been completed at NDC, San Diego... Water and Sodium Ion Concentration on the rate of Crack Propagation and Transverse Strength in Dental Porcelains" has been submitted for publication. An...MARYLAND A long term study to evaluate release kinetics of fluoride from various composite materials was begun. To date, ten different materials have

  7. The effect of grinding and/or airborne-particle abrasion on the bond strength between zirconia and veneering porcelain: a systematic review

    PubMed Central

    Lundberg, Karin; Wu, Lindsey; Papia, Evaggelia

    2017-01-01

    Abstract Objective: The aim of the study was to make an inventory of current literature on the bond strength between zirconia and veneering porcelain after surface treatment of zirconia by grinding with diamond bur and/or with airborne-particle abrasion. Material and methods: The literature search for the present review was made following recommended guidelines using acknowledged methodology on how to do a systematic review. The electronic databases PubMed, Cochrane Library, and Science Direct were used in the present study. Results: Twelve studies were selected. Test methods used in the original studies included shear bond strength (SBS) test, tensile bond strength test, and micro-tensile bond strength test. The majority of studies used SBS. Results showed a large variation within each surface treatment of zirconia, using different grain size, blasting time, and pressure. Conclusions: Airborne-particle abrasion might improve the bond strength and can therefore be considered a feasible surface treatment for zirconia that is to be bonded. Grinding has been recommended as a surface treatment for zirconia to improve the bond strength; however, this recommendation cannot be verified. A standardized test method and surface treatment are required to be able to compare the results from different studies and draw further conclusions. PMID:28642927

  8. [Comparison among three translucency parameters].

    PubMed

    Fang, Xiong; Hui, Xia

    2017-06-01

    This study aims to compare the three commonly used translucency parameters in prosthodontics: transmittance (T), contrast ratio (CR), and translucency parameter (TP). Six platelet specimens were composed of Vita enamel and dental porcelain. The initial thickness was 1.2 mm. The specimens were gradually ground to 1.0, 0.8, 0.6, 0.4, and 0.2 mm. T, color parameters, and reflection were measured by a spectrocolorimeter for each corresponding thickness. T, CR and TP were calculated and compared. TP increased, whereas CR decreased, with decreasing thickness. Moreover, 
T increased with decreasing thickness, and exponential relationships were found. Two-way ANOVA showed statistical significance between T and thickness, except between T and the 1.2 mm and 1.0 mm enamel porcelain groups. No difference was found among the coefficient variations (CV) of T, CR and TP. Curve fitting indicated the existence of exponential relationships between T and CR and between T and TP. The values for goodness of fit with statistical significance were 0.951 and 0.939, respectively (P<0.05). Under the experimental conditions, T, TP and CR achieved the same CV. T and TP, as well as T and CR, were found with exponential relationships. The value of CR and TP could not represent the translucency precisely, especially when comparing the changing ratios.

  9. [The design of Co-Cr-Mo alloy combining the framework with porcelain fused to metal restorations and determination of the mechanical properties].

    PubMed

    Chao, Yong-lie; Lui, Chang-hong; Li, Ning; Yang, Xiao-yu

    2005-02-01

    To investigate a kind of Co-Cr-Mo alloys used for both porcelain fused to metal (PFM) restorations and casting framework of removable partial dentures. The Co-Cr-Mo alloy underwent the design for elementary compositions of the alloys and the production from the raw materials by means of a vacuum melt furnace. The strength, hardness, plasticity and casting ability of the alloy were examined with metal tensile test. Vickers hardness test and grid casting were examined respectively. The microstructure of the Co-Cr-Mo alloy was also inspected by scanning electron microscope and X-ray diffraction analysis. The elementary composition of DA9-4 alloy mainly consisted of Co 54%-67%, Cr 21%-26%, Mo 5%-8%, W 5%-8%, Si 1%-3%, Mn 0.1%-0.25% and trace elements. The yield strength of the alloy was 584 MPa, while the tensile strength was 736 MPa. The coefficient of expansion was 15.0%, the Vickers hardness reached 322, and the casting ratio exibited 100%. The DA9-4 Co-Cr-Mo alloy used for PFM and framework shown in this paper can meet the clinical demands and have reached the objects of the experiment plan.

  10. An approach to biomimetics: the natural CAD/CAM restoration: a clinical report.

    PubMed

    Schlichting, Luís Henrique; Schlichting, Kathryn Klemz; Stanley, Kyle; Magne, Michel; Magne, Pascal

    2014-02-01

    Those in the dental field have always pursued the perfect dental material for the treatment of compromised teeth. Gold, amalgam, composite resin, glass ionomer, and porcelain have been used. Tooth-like restorative materials (composite resin and porcelain) combined with an effective hard tissue bond have met the growing demand for esthetic or metal-free restorations in the past 15 to 20 years. However, none of those materials can fully mimic the unique properties of dentin (compliance and crack-stopping behavior) and enamel (wear resistance, function). The aim of this article is to report the restoration of an extensively damaged tooth with a natural restoration obtained by milling an extracted third molar tooth with a computer-aided design and computer-aided manufacturing (CAD/CAM) system. The main benefit of this novel technique is the replacement of lost tissues by actual enamel and dentin, with the potential to recover mechanical, esthetic, and biologic properties. The indication for extracting third molars and premolars because of impaction or for orthodontic reasons makes these posterior teeth readily available. The innovation of the method presented here is the optimal use of the extracted tooth substrate thanks to its positioning technique in the CAD/CAM milling chamber. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  11. Tracking 800-year-old Shipments: An Archaeological Investigation of the Mado Shipwreck Cargo, Taean, Korea

    NASA Astrophysics Data System (ADS)

    Kim, Minkoo; Moon, Whan Suk

    2011-12-01

    This paper examines cargo from an 800-year-old shipwreck and discusses its implications in relation to the exchange networks and maritime transportation of the Goryeo period (A.D. 918-1392) in Korea. In 2007, two local fishermen fortuitously discovered porcelain vessels from a Goryeo-period shipwreck off the mid-western coast of the Korean peninsula. Underwater excavation conducted by the National Research Institute of Maritime Cultural Heritage (NRIMCH) revealed that the ship was carrying a myriad of cargoes destined for Gaegyeong, the capital of the Goryeo dynasty. Excavation indicates that the main body of the cargo was porcelain vessels produced in the southern part of the peninsula. Archaeobotanical investigation of the wreck deposits revealed that the ship was carrying crops such as rice ( Oryza sativa L.), broomcorn millet ( Panicum miliaceum L.), foxtail millet ( Setaria italica (L.) P. Beauv.), and buckwheat ( Fagopyrum esculentum Moench) bound for the capital. Among the recovered objects were 73 wooden cargo tags with Chinese letters. These tags, equivalent to the modern day air bill, contained detailed information about the senders, recipients, and shipped goods. These findings indicate that during the Goryeo period maritime transportation played an important role in the interpersonal exchange of products over long distances.

  12. Influence of stationary and non-stationary conditions on drying time and mechanical properties of a porcelain slab

    NASA Astrophysics Data System (ADS)

    Hammouda, Imen; Mihoubi, Daoued

    2017-12-01

    This work deals with a numerical study of the response of a porcelain slab when subjected to convective drying in stationary and non-stationary conditions. The used model describes heat, mass, and momentum transfers is applied to an unsaturated viscoelastic medium described by a Maxwell model. The numerical code allows us to determine the effect of the surrounding air temperature on drying kinetics and on mechanical stress intensities. Von Mises stresses are analysed in order to foresee an eventual damage that may occur during drying. Simulation results for several temperatures in the range of [30 °C, 90 °C] shows that for the temperature from 30 °C to 60 °C, Von Mises stresses are always lower than the yield strength. But above 70 °C, Von Mises stresses are higher than the ultimate strength, and consequently there is a risk of crack at the end of the constant drying rate period. The idea proposed in this work is to integrate a reducing temperature phase when the predicted Von Mises stress intensity exceeds the admissible stress. Simulation results shows that a non-stationary convective drying (90-60 °C) allows us to optimize costs and quality by reducing the drying time and maintaining Von Mises stress values under the admissible stress.

  13. Seasonal and latitudinal acclimatization of cardiac transcriptome responses to thermal stress in porcelain crabs, Petrolisthes cinctipes.

    PubMed

    Stillman, Jonathon H; Tagmount, Abderrahmane

    2009-10-01

    Central predictions of climate warming models include increased climate variability and increased severity of heat waves. Physiological acclimatization in populations across large-scale ecological gradients in habitat temperature fluctuation is an important factor to consider in detecting responses to climate change related increases in thermal fluctuation. We measured in vivo cardiac thermal maxima and used microarrays to profile transcriptome heat and cold stress responses in cardiac tissue of intertidal zone porcelain crabs across biogeographic and seasonal gradients in habitat temperature fluctuation. We observed acclimatization dependent induction of heat shock proteins, as well as unknown genes with heat shock protein-like expression profiles. Thermal acclimatization had the largest effect on heat stress responses of extensin-like, beta tubulin, and unknown genes. For these genes, crabs acclimatized to thermally variable sites had higher constitutive expression than specimens from low variability sites, but heat stress dramatically induced expression in specimens from low variability sites and repressed expression in specimens from highly variable sites. Our application of ecological transcriptomics has yielded new biomarkers that may represent sensitive indicators of acclimatization to habitat temperature fluctuation. Our study also has identified novel genes whose further description may yield novel understanding of cellular responses to thermal acclimatization or thermal stress.

  14. Design Guide: Designing and Building High Voltage Power Supplies. Volume 2

    DTIC Science & Technology

    1988-08-01

    and edges. * Isolation system: * One layer ol’ Tedlar: or type 120 glass fabric with a compatible resin : or finish. 199 5.4.2 Composite Joints...plastics Cellulose esters Asphalt Cork Chloride flux Epoxy resins Copper (bare) Masonite Fiber board Melamine resins Greases Nylon Polyvinyl chloride resins ...cycloaliphatic epoxy to a level inferior to the porcelain. In one application having a glass -cloth epoxy- based laminate coated with cycloaliphatic epoxy the

  15. A Comparison of Tensile Bond Strength Between Low Translucency and High Translucency Lithium Disilicate Ceramics Using Two Different Resin Cements

    DTIC Science & Technology

    2015-06-01

    that strengthen the porcelain and limit crack propagation (Apel & colleauges, 2008). Research on lithium-disilicate was first presented to the American...properties. This experimental ceramic showed no cracks with increasing wear cycles and demonstrated less wear upon opposing tooth structure than the...other all-ceramic materials tested (Etman, 2009). Etman concluded that the experimental lithium disilicate showed the highest resistance to crack

  16. Reliability Analysis of Surface Mount Technology (SMT)

    DTIC Science & Technology

    1993-03-01

    INSULATING PROTECTIVE COAT RESISTIVE FILM CCYLINDRICALCCERAMIC CORE 15057-3 Figure 1.3.3.1-2. Metal Electrode Face Bonding (MELF) Resistor 1.3.3.2...control. The dielectric materials are typically G-10 or polyimide. Exotic applications such as porcelain on a core have been found. The core material must...invar cores that provide both a heatsink conduction path and mechanical restraint that forces the composite P&IS CTE to more closely match the SMD CTE

  17. The Effect of Surface Treatment on the Knoop Hardness of DICOR

    DTIC Science & Technology

    1990-01-01

    during an AFIT- sponsored program in Dental Materials. 17. COSATI CODES 18. SUBJECT TERMS (Continue on reverse if necessary and Identify by block number...state of DICOR and harder than human enamel. Shaded DICOR had a surface hardness comparable to dental porcelain. The internal glass-ceramic material...THE EFFECT OF SURFACE TREATMENT ON THE KNOOP HARDNESS OF DICOR W.Patrick Naylor, DDS, MPH, MS* Lieutenant Colonel, US Air Force Dental Corps Brooks

  18. Influence of core design, production technique, and material selection on fracture behavior of yttria-stabilized tetragonal zirconia polycrystal fixed dental prostheses produced using different multilayer techniques: split-file, over-pressing, and manually built-up veneers.

    PubMed

    Mahmood, Deyar Jallal Hadi; Linderoth, Ewa H; Wennerberg, Ann; Vult Von Steyern, Per

    2016-01-01

    To investigate and compare the fracture strength and fracture mode in eleven groups of currently, the most commonly used multilayer three-unit all-ceramic yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) fixed dental prostheses (FDPs) with respect to the choice of core material, veneering material area, manufacturing technique, design of connectors, and radii of curvature of FDP cores. A total of 110 three-unit Y-TZP FDP cores with one intermediate pontic were made. The FDP cores in groups 1-7 were made with a split-file design, veneered with manually built-up porcelain, computer-aided design-on veneers, and over-pressed veneers. Groups 8-11 consisted of FDPs with a state-of-the-art design, veneered with manually built-up porcelain. All the FDP cores were subjected to simulated aging and finally loaded to fracture. There was a significant difference (P<0.05) between the core designs, but not between the different types of Y-TZP materials. The split-file designs with VITABLOCS(®) (1,806±165 N) and e.max(®) ZirPress (1,854±115 N) and the state-of-the-art design with VITA VM(®) 9 (1,849±150 N) demonstrated the highest mean fracture values. The shape of a split-file designed all-ceramic reconstruction calls for a different dimension protocol, compared to traditionally shaped ones, as the split-file design leads to sharp approximal indentations acting as fractural impressions, thus decreasing the overall strength. The design of a framework is a crucial factor for the load bearing capacity of an all-ceramic FDP. The state-of-the-art design is preferable since the split-file designed cores call for a cross-sectional connector area at least 42% larger, to have the same load bearing capacity as the state-of-the-art designed cores. All veneering materials and techniques tested in the study, split-file, over-press, built-up porcelains, and glass-ceramics are, with a great safety margin, sufficient for clinical use both anteriorly and posteriorly. Analysis of the fracture pattern shows differences between the milled veneers and over-pressed or built-up veneers, where the milled ones show numerically more veneer cracks and the other groups only show complete connector fractures.

  19. Shade matching performance of normal and color vision-deficient dental professionals with standard daylight and tungsten illuminants.

    PubMed

    Gokce, Hasan Suat; Piskin, Bulent; Ceyhan, Dogan; Gokce, Sila Mermut; Arisan, Volkan

    2010-03-01

    The lighting conditions of the environment and visual deficiencies such as red-green color vision deficiency affect the clinical shade matching performance of dental professionals. The purpose of this study was to evaluate the shade matching performance of normal and color vision-deficient dental professionals with standard daylight and tungsten illuminants. Two sets of porcelain disc replicas of 16 shade guide tabs (VITA Lumin) were manufactured to exact L*a*b* values by using a colorimeter. Then these twin porcelain discs (13 mm x 2.4 mm) were mixed up and placed into a color-matching cabinet that standardized the lighting conditions for the observation tests. Normal and red-green color vision-deficient dental professionals were asked to match the 32 porcelain discs using standard artificial daylight D65 (high color temperature) and tungsten filament lamp light (T) (low color temperature) illuminants. The results were analyzed by repeated-measures ANOVA and paired and independent samples t tests for the differences between dental professionals and differences between the illuminants (alpha=.05). Regarding the sum of the correct shade match scores of all observations with both illuminants, the difference between normal vision and red-green color vision-deficient dental professional groups was not statistically significant (F=4.132; P=.054). However, the correct shade match scores of each group were significantly different for each illuminant (P<.005). The correct shade matching scores of normal color vision dental professionals were significantly higher with D65 illuminant (t=7.004; P<.001). Color matching scores of red-green color vision-deficient dental professionals (approximately 5.7 more pairs than with D65) were significantly higher with T illuminant (t=5.977; P<.001). CONCLUSIONS.: Within the limitations of this study, the shade matching performance of dental professionals was affected by color vision deficiency and the color temperature of the illuminant. The color vision-deficient group was notably unsuccessful with the D65 illuminant in shade matching. In contrast, there was a significant increase in the shade matching performance of the color vision-deficient group with T illuminant. The lower color temperature illuminant dramatically decreased the normal color vision groups' correct shade matching score. (c) 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  20. Thermal expansion and microstructural analysis of experimental metal-ceramic titanium alloys.

    PubMed

    Zinelis, Spiros; Tsetsekou, Athena; Papadopoulos, Triantafillos

    2003-10-01

    Statement of problem Low-fusing porcelains for titanium veneering have demonstrated inferior color stability and metal-ceramic longevity compared to conventional porcelains. This study evaluated the microstructure and thermal expansion coefficients of some experimental titanium alloys as alternative metallic substrates for low-fusing conventional porcelain. Commercially pure titanium (CP Ti) and various metallic elements (Al, Co, Sn, Ga, In, Mn) were used to prepare 8 titanium alloys using a commercial 2-chamber electric-arc vacuum/inert gas dental casting machine (Cyclarc). The nominal compositions of these alloys were the following (wt%): I: 80Ti-18Sn-1.5In-0.5Mn; II: 76Ti-12Ga-7Sn-4Al-1Co; III: 87Ti-13Ga; IV: 79Ti-13Ga-7Al-1Co; V: 82Ti-18In; VI: 75.5Ti-18In-5Al-1Co-0.5Mn; VII: 85Ti-10Sn-5Al; VIII: 78Ti-12Co-7Ga-3Sn. Six rectangular wax patterns for each test material (l = 25 mm, w = 3 mm, h = 1 mm) were invested with magnesia-based material and cast with grade II CP Ti (control) and the 8 experimental alloys. The porosity of each casting was evaluated radiographically, and defective specimens were discarded. Two cast specimens from CP Ti and alloys I-VIII were embedded in epoxy resin and, after metallographic grinding and polishing, were studied by means of scanning electron microscopy and wavelength dispersive electron probe microanalysis. One specimen of each material was utilized for the determination of coefficient of thermal expansion (CTE) with a dilatometer operating from room temperature up to 650 degrees C at a heating rate of 5 degrees C/minute. Secondary electron images (SEI) and compositional backscattered electron images (BEI-COMPO) revealed that all cast specimens consisted of a homogeneous matrix except Alloy VIII, which contained a second phase (possibly Ti(2)Co) along with the titanium matrix. The results showed that the coefficient of thermal expansion (CTE) varied from 10.1 to 13.1 x 10(-6)/ degrees C (25 degrees -500 degrees C), depending on the elemental composition. The CTE of titanium can be considerably changed by alloying. Two-phase alloys were developed when alloying elements were added in concentrations greater than the maximum solubility limit in alpha-titanium phase.

  1. [Experimental analysis of finishing lines in ceramometal restorations].

    PubMed

    Gascón, F; Gil, J A; Fons, A; Badal, R

    1990-11-01

    The preparation is the first step of any tooth reconstruction. The biological integration of the protesis is depending on the marginal adaptation (finish line of the preparation), occlusal adaptation (occlusal reduction), longevity of the restoration (retention and luting) and esthetics. The effect the two finish line of the preparation is studied using experimental design. In porcelain-fused-to-metal the finish line of the preparation in chanfer is superior at the beveled shoulder, because proportioning better marginal adaptation.

  2. Materials for High-Density Electronic Packaging and Interconnection

    DTIC Science & Technology

    1990-04-10

    play a prominent role in the future. Glass and Porcelain The earliest use of electronic ceramics was as insulators for carrying telegraph lines...Administration 61L & CORES , (Ot. stem. SAI WCJm 76. LOISS (C". SUMt *oW WVCf B’%2101 Constitution Avenue. N W Washington, D.C. 20418 Washington. D.C. 20301 G...Density Packaging 84 Tape Automated Bonding 87 Diamond 88 Superconductors 88 Composites 89 Materials for Very-High-Frequency Digital Systems 91

  3. Thermo-Mechanical and Thermal behavior of High-Temperature Structural Materials.

    DTIC Science & Technology

    1982-12-31

    34-’- Mr. 3. D. SilboldMr-J-..ibl Columbus, OH 43201 Coor Porcelain Company 17750 W. 32nd Avenue Dr. R. E. Engdahl Golden, CO 80401 Deposits and Composites ...number) Thermal shock, thermal stress, thermal diffusivity, thermal conductivity; refractories, composites , radiation heat transfer, cyclic heating...Hasselman and R. Ruh, "Effect of Hot-Pressing 4 -; Temperature on the Thermal Diffusivity/Conductivity of SiC-AIN Composites ." III M. A. Bucknam, L. D

  4. Effect of Polishing Systems on Surface Roughness and Topography of Monolithic Zirconia.

    PubMed

    Goo, C L; Yap, Auj; Tan, Kbc; Fawzy, A S

    2016-01-01

    This study evaluated the effect of different chairside polishing systems on the surface roughness and topography of monolithic zirconia. Thirty-five monolithic zirconia specimens (Lava PLUS, 3M ESPE) were fabricated and divided into five groups of seven and polished with the following: Group 1 (WZ)-Dura white stone followed by Shofu zirconia polishing kit; Group 2 (SZ)-Shofu zirconia polishing kit; Group 3 (CE)-Ceramiste porcelain polishers; Group 4 (CM)-Ceramaster porcelain polishers; and Group 5 (KZ)-Komet ZR zirconia polishers. All specimens were ground with a fine-grit diamond bur prior to polishing procedures to simulate clinical finishing. Baseline and post-polishing profilometric readings were recorded and delta Ra values (difference in mean surface roughness before and after polishing) were computed and analyzed using one-way analysis of variance and Scheffe post hoc test (p<0.05). Representative scanning electron microscopy (SEM) images of the ground but unpolished and polished specimens were acquired. Delta Ra values ranged from 0.146 for CE to 0.400 for KZ. Delta Ra values for KZ, WZ, and SZ were significantly greater than for CE. Significant differences in delta Ra values were also observed between KZ and CM. The SEM images obtained were consistent with the profilometric findings. Diamond-impregnated polishing systems were more effective than silica carbide-impregnated ones in reducing the surface roughness of ground monolithic zirconia.

  5. [Influence of SiO2 films on color reproduction of Ni-Cr alloy porcelain crowns].

    PubMed

    Wu, Dong; Feng, Yunzhi

    2011-08-01

    To study whether SiO2 films will influence the color of Ni-Cr metal ceramic restorations. For the film plating experimental group, Sol-gel method was employed to apply SiO2 films to the surface of the Ni-Cr copings, while no coating was applied for the non-film-plating control group. Veneering porcelains were then applied subsequently, and a total of 12 B2-colored maxillary incisor metal ceramic crowns were fabricated with 6 crowns in each group. A ShadeEye Ncc computer-aided colorimeter was employed to measure the shade of the samples, as well as 6 B2(Vitapan classical vita color tabs) shade standards. The color was expressed as C1E-1976-Lab coordinates. There was a statistically significant color difference between all metal ceramic crowns and the B2 shade standards (delta E>1.5). The L*, a*, b* values of all crowns were higher than those of the B2 shade standards, and the crowns were typically yellower or redder. While neither significant color difference nor difference in shade values was observed between the film plating experimental group and non-film-plating control group (delta E<1.5). SiO2 films applied to the Ni-Cr copings by means of Sol-gel technique do not impact the final color of the metal ceramic restorations.

  6. Topological design of all-ceramic dental bridges for enhancing fracture resistance.

    PubMed

    Zhang, Zhongpu; Chen, Junning; Li, Eric; Li, Wei; Swain, Michael; Li, Qing

    2016-06-01

    Layered all-ceramic systems have been increasingly adopted in major dental prostheses. However, ceramics are inherently brittle, and they often subject to premature failure under high occlusion forces especially in the posterior region. This study aimed to develop mechanically sound novel topological designs for all-ceramic dental bridges by minimizing the fracture incidence under given loading conditions. A bi-directional evolutionary structural optimization (BESO) technique is implemented within the extended finite element method (XFEM) framework. Extended finite element method allows modeling crack initiation and propagation inside all-ceramic restoration systems. Following this, BESO searches the optimum distribution of two different ceramic materials, namely porcelain and zirconia, for minimizing fracture incidence. A performance index, as per a ratio of peak tensile stress to material strength, is used as a design objective. In this study, the novel XFEM based BESO topology optimization significantly improved structural strength by minimizing performance index for suppressing fracture incidence in the structures. As expected, the fracture resistance and factor of safety of fixed partial dentures structure increased upon redistributing zirconia and porcelain in the optimal topological configuration. Dental CAD/CAM systems and the emerging 3D printing technology were commercially available to facilitate implementation of such a computational design, exhibiting considerable potential for clinical application in the future. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Amelogenesis Imperfecta and Early Restorative Crown Therapy: An Interview Study with Adolescents and Young Adults on Their Experiences

    PubMed Central

    Wickström, Anette; Hasselblad, Tove; Dahllöf, Göran

    2016-01-01

    Patients with Amelogenesis imperfecta (AI) can present with rapid tooth loss or fractures of enamel as well as alterations in enamel thickness, color, and shape; factors that may compromise aesthetic appearance and masticatory function. The aim was to explore the experiences and perceptions of adolescents and young adults living with AI and receiving early prosthetic therapy. Seven patients with severe AI aged 16 to 23 years who underwent porcelain crown therapy participated in one-to-one individual interviews. The interviews followed a topic guide consisting of open-ended questions related to experiences of having AI. Transcripts from the interviews were analyzed using thematic analysis. The analysis process identified three main themes: Disturbances in daily life, Managing disturbances, and Normalization of daily life. These themes explain the experiences of patients living with enamel disturbances caused by AI and receiving early crown therapy. Experiences include severe pain and sensitivity problems, feelings of embarrassment, and dealing with dental staff that lack knowledge and understanding of their condition. The patients described ways to manage their disturbances and to reduce pain when eating or drinking, and strategies for meeting other people. After definitive treatment with porcelain crown therapy, they described feeling like a normal patient. In conclusion the results showed that adolescents and young adults describe a profound effect of AI on several aspects of their daily life. PMID:27359125

  8. Clinical experiences of implant-supported prostheses with laser-welded titanium frameworks in the partially edentulous jaw: a 5-year follow-up study.

    PubMed

    Ortorp, A; Jemt, T

    1999-01-01

    Titanium frameworks have been used in the endentulous implant patient for the last 10 years. However, knowledge of titanium frameworks for the partially dentate patient is limited. To report the 5-year clinical performance of implant-supported prostheses with laser-welded titanium frameworks in the partially edentulous jaw. A consecutive group of 383 partially edentulous patients were, on a routine basis, provided with fixed partial prostheses supported by Brånemark implants in the mandible or maxilla. Besides conventional frameworks in cast gold alloy, 58 patients were provided with titanium frameworks with three different veneering techniques, and clinical and radiographic 5-year data were collected for this group. The overall cumulative survival rate was 95.6% for titanium-framework prostheses and 93.6% for implants. Average bone loss during the follow-up period was 0.4 mm. The most common complications were minor veneering fractures. Loose and fractured implant screw components were fewer than 2%. An observation was that patients on medications for cardiovascular problems may lose more implants than others (p < .05). The clinical performance of prostheses with implant-supported laser-welded titanium frameworks was similar to that reported for conventional cast frames in partially edentulous jaws. Low-fusing porcelain veneers also showed clinical performance comparable to that reported for conventional porcelain-fused-to-metal techniques.

  9. Non-destructive characterization of oriental porcelain glazes and blue underglaze pigments using μ-EDXRF, μ-Raman and VP-SEM

    NASA Astrophysics Data System (ADS)

    Coutinho, M. L.; Muralha, V. S. F.; Mirão, J.; Veiga, J. P.

    2014-03-01

    The study of ancient materials with recognized cultural and economic value is a challenge to scientists and conservators, since it is usually necessary an approach through non-destructive techniques. Difficulties in establishing a correct analytical strategy are often significantly increased by the lack of knowledge on manufacture technologies and raw materials employed combined with the diversity of decay processes that may have acted during the lifetime of the cultural artefacts. A non-destructive characterization was performed on the glaze and underglaze pigments from a group of Chinese porcelain shards dated from the late Ming Dynasty (1368-1644) excavated at the Monastery of Santa Clara- a- Velha in Coimbra (Portugal). Chemical analysis was performed using micro-energy dispersive X-ray fluorescence spectrometry (μ-EDXRF). Mineralogical characterization was achieved by Raman microscopy (μ-Raman) and observation of small-surface crystallization dark spots with a metallic lustre in areas with high pigment concentration was done by variable pressure scanning electron microscopy (VP-SEM). Cobalt aluminate was identified as the blue underglaze pigment and a comparison of blue and dark blue pigments was performed by the ratio of Co, Mn, and Fe oxides, indicating a compositional difference between the two blue tonalities. Manganese oxide compounds were also identified as colouring agents in dark blue areas and surface migration of manganese compounds was verified.

  10. Analysis of vertical marginal discrepancy in feldspathic porcelain crowns manufactured with different CAD/CAM systems: Closed and open.

    PubMed

    Kricheldorf, Fabio; Bueno, Cleuber Rodrigo de Souza; Amaral, Wilson da Silva; Junior, Joel Ferreira Santiago; Filho, Hugo Nary

    2018-01-01

    The objective of this study is to compare the marginal adaptation of feldspathic porcelain crowns using two computer-aided design/computer-aided manufacturing systems, one of them is open and the other is closed. Twenty identical titanium abutments were divided into two groups: open system (OS), where ceramic crowns were created using varied equipment and software, and closed system (CS), where ceramic crowns were created using the CEREC system. Through optical microscopy analysis, we assess the marginal adaptation of the prosthetic interfaces. The data were subjected to the distribution of normality and variance. The t -test was used for the analysis of the comparison factor between the groups, and the one-way ANOVA was used to compare the variance of crown analysis regions within the group. A significance level of 5% was considered for the analyses. There was a significant difference between the systems ( P = 0.007), with the CS group having the higher mean (23.75 μm ± 3.05) of marginal discrepancy when compared to the open group (17.94 μm ± 4.77). Furthermore, there were no differences in marginal discrepancy between the different points between the groups ( P ≥ 0.05). The studied groups presented results within the requirements set out in the literature. However, the OS used presented better results in marginal adaptation.

  11. [Preliminary evaluation of plastic crown restoration supported by osseointegrated implants].

    PubMed

    Huang, J; Zhang, K

    1997-08-01

    This study was to evaluate the feasibility of plastic crown restoration supported by osseointegrated implants. The following conclusions were drawn from this study: plastic crown gave better biomechanical consideration than porcelain fused to metal (PFM) crown in osseointegrated prostheses, but plastic crown gave worse wearability, tensile strength, compression strength and flexuaral strength than PFM crown. After restoration the disadvantages of the plastic crown were beyond the clinical acceptable range. It showed plastic crown designed dental prothetic implantation was unfeasible.

  12. 40 CFR 466.32 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Aluminum Basis Material....19 5.06 0.16 Nickel 54.85 1.78 38.90 1.26 Zinc 51.74 1.68 21.79 1.71 Aluminum 176.98 5.74 72.35 2.35... Aluminum 36.25 1.18 14.82 0.48 Iron 9.80 0.32 5.02 0.16 [47 FR 53184, Nov. 24, 1982, as amended at 50 FR...

  13. 40 CFR 466.33 - New source performance standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... GUIDELINES AND STANDARDS PORCELAIN ENAMELING POINT SOURCE CATEGORY Aluminum Basis Material Subcategory § 466....11 Nickel 5.35 0.69 3.60 0.47 Zinc 9.92 1.29 4.09 0.53 Aluminum 29.46 3.82 12.06 1.56 Iron 11.96 1.55... 0.03 0.18 0.20 Nickel 1.10 0.14 0.74 0.10 Zinc 2.03 0.27 0.84 0.11 Aluminum 6.03 0.78 2.47 0.32 Iron...

  14. An Evaluation of the Marginal Sharpness of the Porcelain Labial Margin Metal Ceramic Restoration

    DTIC Science & Technology

    1991-05-01

    increase in sulcular fluid, being a measure of the inflammatory reaction present, would remain constant even if the patient’s oral hygiene was good...While treatment planning the metal ceramic restoration, the dentist must decide where to place the thin facial margin of metal. If it is placed at the...that the concept of "extension for prevention" was no longer valid and a new theoretical basis for the prophylactic treatment of caries and periodontal

  15. Cryogenic Properties of Inorganic Insulation Materials for ITER Magnets: A Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simon, N.J.

    1994-12-01

    Results of a literature search on the cryogenic properties of candidate inorganic insulators for the ITER TF magnets are reported. The materials investigated include: Al{sub 2}O{sub 3}, AlN, MgO, porcelain, SiO{sub 2}, MgAl{sub 2}O{sub 4}, ZrO{sub 2}, and mica. A graphical presentation is given of mechanical, elastic, electrical, and thermal properties between 4 and 300 K. A companion report reviews the low temperature irradiation resistance of these materials.

  16. 61. VIEW LOOKING NORTHWEST AT A SIGNAL REACTOR OR CHOKE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    61. VIEW LOOKING NORTHWEST AT A SIGNAL REACTOR OR CHOKE COIL. WITHIN THE PROTECTIVE ENCLOSURE IS AN AIR AND PORCELAIN INSULATED COIL OF 5/8' DIAMETER STRANDED COPPER WIRE. REACTOR COILS WERE PLACED IN SERIES WITH EACH LEG OF THREE PHASE GENERATORS. THEIR FUNCTION WAS TO MODERATE SURGES OF CURRENT CAUSED BY LIGHTNING STRIKES, OPEN OR SHORT CIRCUIT PROBLEMS ON THE LINE. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  17. Infrared Heaters

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The heating units shown in the accompanying photos are Panelbloc infrared heaters, energy savers which burn little fuel in relation to their effective heat output. Produced by Bettcher Manufacturing Corporation, Cleveland, Ohio, Panelblocs are applicable to industrial or other facilities which have ceilings more than 12 feet high, such as those pictured: at left the Bare Hills Tennis Club, Baltimore, Maryland and at right, CVA Lincoln- Mercury, Gaithersburg, Maryland. The heaters are mounted high above the floor and they radiate infrared energy downward. Panelblocs do not waste energy by warming the surrounding air. Instead, they beam invisible heat rays directly to objects which absorb the radiation- people, floors, machinery and other plant equipment. All these objects in turn re-radiate the energy to the air. A key element in the Panelbloc design is a coating applied to the aluminized steel outer surface of the heater. This coating must be corrosion resistant at high temperatures and it must have high "emissivity"-the ability of a surface to emit radiant energy. The Bettcher company formerly used a porcelain coating, but it caused a production problem. Bettcher did not have the capability to apply the material in its own plant, so the heaters had to be shipped out of state for porcelainizing, which entailed extra cost. Bettcher sought a coating which could meet the specifications yet be applied in its own facilities. The company asked The Knowledge Availability Systems Center, Pittsburgh, Pennsylvania, a NASA Industrial Applications Center (IAC), for a search of NASA's files

  18. Direct Tensile Strength and Characteristics of Dentin Restored with All-Ceramic, Resin-Composite, and Cast Metal Prostheses Cemented with Resin Adhesives

    PubMed Central

    Piemjai, Morakot; Nakabayashi, Nobuo

    2015-01-01

    A dentin-cement-prosthesis complex restored with either all-porcelain, cured resin-composite, or cast base metal alloy and cemented with either of the different resin cements was trimmed into a mini-dumbbell shape for tensile testing. The fractured surfaces and characterization of the dentin-cement interface of bonded specimens were investigated using a Scanning Electron Microscope. A significantly higher tensile strength of all-porcelain (12.5 ± 2.2 MPa) than that of cast metal (9.2 ± 3.5 MPa) restorations was revealed with cohesive failure in the cement and failure at the prosthesis-cement interface in Super-Bond C&B group. No significant difference in tensile strength was found among the types of restorations using the other three cements with adhesive failure on the dentin side and cohesive failure in the cured resin. SEM micrographs demonstrated the consistent hybridized dentin in Super-Bond C&B specimens that could resist degradation when immersed in hydrochloric acid followed by NaOCl solutions whereas a detached and degraded interfacial layer was found for the other cements. The results suggest that when complete hybridization of resin into dentin occurs tensile strength at the dentin-cement is higher than at the cement-prosthesis interfaces. The impermeable hybridized dentin can protect the underlying dentin and pulp from acid demineralization, even if detachment of the prosthesis has occurred. PMID:26539520

  19. Effect of various intermediate ceramic layers on the interfacial stability of zirconia core and veneering ceramics.

    PubMed

    Yoon, Hyung-In; Yeo, In-Sung; Yi, Yang-Jin; Kim, Sung-Hun; Lee, Jai-Bong; Han, Jung-Suk

    2015-01-01

    The purposes of this study were to evaluate the effects of intermediate ceramics on the adhesion between the zirconia core and veneer ceramics. The polished surfaces of fully sintered Y-TZP blocks received three different treatments: (1) connector (C), (2) liner (L) or (3) wash layer (W). All the treated zirconia blocks were veneered with either (a) fluorapatite glass-ceramic (E) or (b) feldspathic porcelain (V) and divided into four groups (CE, CV, LE and WV). For the control group, the testing surfaces of metal blocks were veneered with feldspathic porcelain (VM). A half of the samples in each group (n = 21) were exposed to thermocycling, while the other half of the specimens were stored at room temperature under dry conditions. All specimens were subjected to the shear test and the failed surfaces were microscopically examined. The elemental distribution at the zirconia core/veneer interface was analyzed. The specimens in Groups CE and CV exhibited significantly greater mean bond strength values than those in Groups LE and WV, respectively (p < 0.05). However, the mean bond strengths significantly decreased in the connector groups (CE and CV) after thermal cycling (p < 0.05). The elemental analysis suggested diffusion of ceramic substances into the zirconia surface. A glass-ceramic based connector is significantly more favorable to core/veneer adhesion than the other intermediate ceramics evaluated in the study. However, thermal cycling affected the bond strength at the core/veneer interface differently according to the intermediate ceramics.

  20. Influence of enamel preservation on failure rates of porcelain laminate veneers.

    PubMed

    Gurel, Galip; Sesma, Newton; Calamita, Marcelo A; Coachman, Christian; Morimoto, Susana

    2013-01-01

    The purpose of this study was to evaluate the failure rates of porcelain laminate veneers (PLVs) and the influence of clinical parameters on these rates in a retrospective survey of up to 12 years. Five hundred eighty laminate veneers were bonded in 66 patients. The following parameters were analyzed: type of preparation (depth and margin), crown lengthening, presence of restoration, diastema, crowding, discoloration, abrasion, and attrition. Survival was analyzed using the Kaplan-Meier method. Cox regression modeling was used to determine which factors would predict PLV failure. Forty-two veneers (7.2%) failed in 23 patients, and an overall cumulative survival rate of 86% was observed. A statistically significant association was noted between failure and the limits of the prepared tooth surface (margin and depth). The most frequent failure type was fracture (n = 20). The results revealed no significant influence of crown lengthening apically, presence of restoration, diastema, discoloration, abrasion, or attrition on failure rates. Multivariable analysis (Cox regression model) also showed that PLVs bonded to dentin and teeth with preparation margins in dentin were approximately 10 times more likely to fail than PLVs bonded to enamel. Moreover, coronal crown lengthening increased the risk of PLV failure by 2.3 times. A survival rate of 99% was observed for veneers with preparations confined to enamel and 94% for veneers with enamel only at the margins. Laminate veneers have high survival rates when bonded to enamel and provide a safe and predictable treatment option that preserves tooth structure.

  1. Effect of different dental ceramic systems on the wear of human enamel: An in vitro study.

    PubMed

    Zandparsa, Roya; El Huni, Rabie M; Hirayama, Hiroshi; Johnson, Marc I

    2016-02-01

    The wear of tooth structure opposing different advanced dental ceramic systems requires investigation. The purpose of this in vitro study was to compare the wear of advanced ceramic systems against human enamel antagonists. Four ceramic systems (IPS e.max Press, IPS e.max CAD, Noritake Super Porcelain EX-3, and LAVA Plus Zirconia) and 1 control group containing human enamel specimens were used in this study (n = 12). All specimens were fabricated as disks 11 mm in diameter and 3 mm thick. The mesiopalatal cusps of the maxillary third molars were prepared to serve as the enamel styluses. All specimens were embedded individually in 25 mm(3) autopolymerizing acrylic resin blocks. Wear was measured with a cyclic loading machine and a newly designed wear simulator. All enamel styluses (cusps) were scanned using the Activity 880 digital scanner (SmartOptics). Data from the base line and follow-up scans were collected and compared with Qualify 2012 3-dimensional (3D) and 2D digital inspection software (Geomagic), which aligned the models and detected the geometric changes and the wear caused by the antagonist specimen. One-way ANOVA was used to analyze the collected data. After 125,000 bidirectional loading cycles, the mean loss of opposing enamel volume for the enamel disks in the control group was 37.08 μm(3), the lowest mean value for IPS e.max Press system was 39.75 μm(3); 40.58 μm(3) for IPS e.max CAD; 45.08 μm(3) for Noritake Super Porcelain EX-3 system; and 48.66 μm(3) for the Lava Plus Zirconia system. No statically significant differences were found among the groups in opposing enamel volume loss (P=.225) or opposing enamel height loss (P=.149). In terms of opposing enamel height loss, Lava Plus Zirconia system showed the lowest mean value of 27.5 μm. The mean value for the IPS e.max CAD system was 27.91 μm; 29.08 μm for the control enamel; 33.25 μm for the IPS e.max Press system; and 34.75 μm for the Noritake Super Porcelain EX-3 system. Within the limitations of this in vitro study, no differences were found in the linear and volumetric reduction of enamel cusps abraded against enamel disks and all other ceramic specimens. All ceramic systems exhibited high durability and were wear-friendly to opposing enamel. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Mechanical fatigue degradation of ceramics versus resin composites for dental restorations.

    PubMed

    Belli, Renan; Geinzer, Eva; Muschweck, Anna; Petschelt, Anselm; Lohbauer, Ulrich

    2014-04-01

    For posterior partial restorations an overlap of indication exists where either ceramic or resin-based composite materials can be successfully applied. The aim of this study was to compare the fatigue resistance of modern dental ceramic materials versus dental resin composites in order to address such conflicts. Bar specimens of five ceramic materials and resin composites were produced according to ISO 4049 and stored for 14 days in distilled water at 37°C. The following ceramic materials were selected for testing: a high-strength zirconium dioxide (e.max ZirCAD, Ivoclar), a machinable lithium disilicate (e.max CAD, Ivoclar), a pressable lithium disilicate ceramic (e-max Press, Ivoclar), a fluorapatite-based glass-ceramic (e.max Ceram, Ivoclar), and a machinable color-graded feldspathic porcelain (Trilux Forte, Vita). The composite materials selected were: an indirect machinable composite (Lava Ultimate, 3M ESPE) and four direct composites with varying filler nature (Clearfil Majesty Posterior, Kuraray; GrandioSO, Voco; Tetric EvoCeram, Ivoclar-Vivadent; and CeramX Duo, Dentsply). Fifteen specimens were tested in water for initial strength (σin) in 4-point bending. Using the same test set-up, the residual flexural fatigue strength (σff) was determined using the staircase approach after 10(4) cycles at 0.5 Hz (n=25). Weibull parameters σ0 and m were calculated for the σin specimens, whereas the σff and strength loss in percentage were obtained from the fatigue experiment. The zirconium oxide ceramic showed the highest σin and σff (768 and 440 MPa, respectively). Although both lithium disilicate ceramics were similar in the static test, the pressable version showed a significantly higher fatigue resistance after cyclic loading. Both the fluorapatite-based and the feldspathic porcelain showed equivalent initial and cyclic fatigue properties. From the composites, the highest filled direct material Clearfil Majesty Posterior showed superior fatigue performance. From all materials, e.max Press and Clearfil Majesty Posterior showed the lowest strength loss (29.6% and 32%, respectively), whereas the other materials lost between 41% and 62% of their flexural strength after cyclic loading. Dental ceramics and resin composite materials show equivalent fatigue strength degradation at loads around 0.5σin values. Apart from the zirconium oxide and the lithium disilicate ceramics, resin composites generally showed better σff after 10,000 cycles than the fluorapatite glass-ceramic and the feldspathic porcelain. Resin composite restorations may be used as an equivalent alternative to glass-rich-ceramic inlays regarding mechanical performance. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  3. Impact of Steep-Front Short-Duration Impulse on Electric Power System Insulation. Phase 2. Laboratory Evaluation of Selected Power System Components

    DTIC Science & Technology

    1991-04-01

    SEALS - _------ OIL LEVEL STAINLESS STEEL INDICATOR EXPANSION CHAMBER MULTIPLE COMPRESSION GASKET SPRINGS CONDUCTOR RO) UPPER PORCELAIN_ OIL...GENERATED WAVEFORM) FIELD Electric (E) 40 kV/m 50 kV/m 10 kV/m STRENGTH ( FREE SPACE) Magnetic(M) 300 A/m 1000 A/m 300 A/m Rise time 20-500 ns 10 ns 10 ns...Laboratory Interaction Note IN435, 1983. 4. P. R_ Barnes, "The Axial Current Induced on an Infinitely Long, Perfectly Conducting, Circular Cylinder in Free

  4. A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns.

    PubMed

    Sulaiman, F; Chai, J; Jameson, L M; Wozniak, W T

    1997-01-01

    The in vitro marginal fit of three all-ceramic crown systems (In-Ceram, Procera, and IPS Empress) was compared. All crown systems were significantly different from each other at P = 0.05. In-Ceram exhibited the greatest marginal discrepancy (161 microns), followed by Procera (83 microns), and IPS Empress (63 microns). There were no significant differences among the various stages of the crown fabrication: core fabrication, porcelain veneering, and glazing. The facial and lingual margins exhibited significantly larger marginal discrepancies than the mesial and distal margins.

  5. Evaluation of Adhesive Bonding of Lithium Disilicate Ceramic Material with Duel Cured Resin Luting Agents

    PubMed Central

    Gundawar, Sham M.; Radke, Usha M.

    2015-01-01

    Purpose: The purpose of this vitro study was to comparatively evaluate the adhesive bonding of dual cured resin luting agents with lithium disilicate ceramic material. Materials and Methods: Porcelain laminate veneers were prepared with lithium disilicate ceramic material i.e. IPS Empress II( E-Max Press). These laminates were bonded with RelyX ARC, Panavia F 2.0, Variolink II, Duolink and Nexus NX3.The porcelain laminates were etched with 9.6% hydrofluoric acid (Pulpdent Corporation) for one minute, washed for 15 sec with three way syringe and dried for 15 sec with air syringe. The silane (Ultradent) was applied with the help of applicator tip in a single coat and kept undisturbed for one minute. The prepared surfaces of the premolars were treated with 37% phosphoric acid (Prime dent) for 15 sec, thoroughly rinsed and dried as per manufactures instructions. The shear bond test was carried out on all samples with the Universal testing machine (Instron U.S.A.) The scanning electron microscopic study was performed at the fractured interface of representative samples from each group of luting agents. Result: In this study, the highest value of shear bond strength was obtained for NEXUS NX3 and the lowest for VARIOLINK II. Conclusion: The difference in bond strength can be interpreted as the difference in fracture resistance of luting agents, to which shearing load was applied during the shear bond strength test. It is inferred from this study that the composition of the luting agent determines the adhesive characteristics in addition to surface treatment and bonding surface area. PMID:25859514

  6. Stress distribution in fixed-partial prosthesis and peri-implant bone tissue with different framework materials and vertical misfit levels: a three-dimensional finite element analysis.

    PubMed

    Bacchi, Ataís; Consani, Rafael L X; Mesquita, Marcelo F; dos Santos, Mateus B F

    2013-09-01

    The purpose of this study was to evaluate the influence of superstructure material and vertical misfits on the stresses created in an implant-supported partial prosthesis. A three-dimensional (3-D) finite element model was prepared based on common clinical data. The posterior part of a severely resorbed jaw with two osseointegrated implants at the second premolar and second molar regions was modeled using specific modeling software (SolidWorks 2010). Finite element models were created by importing the solid model into mechanical simulation software (ANSYS Workbench 11). The models were divided into groups according to the prosthesis framework material (type IV gold alloy, silver-palladium alloy, commercially pure titanium, cobalt-chromium alloy, or zirconia) and vertical misfit level (10 µm, 50 µm, and 100 µm) created at one implant-prosthesis interface. The gap of the vertical misfit was set to be closed and the stress values were measured in the framework, porcelain veneer, retention screw, and bone tissue. Stiffer materials led to higher stress concentration in the framework and increased stress values in the retention screw, while in the same circumstances, the porcelain veneer showed lower stress values, and there was no significant difference in stress in the peri-implant bone tissue. A considerable increase in stress concentration was observed in all the structures evaluated within the misfit amplification. The framework material influenced the stress concentration in the prosthetic structures and retention screw, but not that in bone tissue. All the structures were significantly influenced by the increase in the misfit levels.

  7. Consecutive unsplinted implant-supported restorations to replace lost multiple adjacent posterior teeth: A 4-year prospective cohort study.

    PubMed

    Lee, Jung-Tae; Lee, Hyo-Jung; Park, Shin-Young; Kim, Hae-Young; Yeo, In-Sung

    2015-08-01

    The aim of this study was to investigate the various events occurring in unsplinted implant restoration in posterior jaws during a period of 4 years. From August 2008 to April 2009, eight volunteers (three men and five women) who had two or more consecutively missing teeth received 20 implants in posterior maxillae and mandibles. Unsplinted single crowns were delivered to each implant. For the 4-year follow-up periods, patients were enrolled in a maintenance schedule at 1, 3, 6, 12, 24, 36 and 48 months. The data, including a questionnaire, radiography, mobility and probing were recorded on regular check-ups. A total of 20 implants in eight patients were followed up for 48 months, showing a 100% survival rate. Mean marginal bone loss around implants was 0.26 mm. Statistical analysis revealed insignificant correlation between metal-ceramic and zirconia-ceramic crowns and among implant lengths (8.5 mm, 10 mm and 11.5 mm). Mean probing depths were similar or insignificantly different, regardless of the materials used or length of implants. The most frequent complications, in decreasing order, were food impaction (65%) and porcelain chipping (45%), sensitivity (25%), pain (20%) and loose contact (15%). Compared with metal-ceramic crowns, zirconia-ceramic crowns showed more unfavorable cases of porcelain chipping (p=0.017), pain (p=0.007) and loose contact with an adjacent crown (p=0.031). Within the limits of the sample size, this study showed that unsplinted implant-supported single restorations to replace consecutive posterior missing teeth may function well.

  8. Effect of elevated pCO2 on metabolic responses of porcelain crab (Petrolisthes cinctipes) Larvae exposed to subsequent salinity stress.

    PubMed

    Miller, Seth H; Zarate, Sonia; Smith, Edmund H; Gaylord, Brian; Hosfelt, Jessica D; Hill, Tessa M

    2014-01-01

    Future climate change is predicted to alter the physical characteristics of oceans and estuaries, including pH, temperature, oxygen, and salinity. Investigating how species react to the influence of such multiple stressors is crucial for assessing how future environmental change will alter marine ecosystems. The timing of multiple stressors can also be important, since in some cases stressors arise simultaneously, while in others they occur in rapid succession. In this study, we investigated the effects of elevated pCO2 on oxygen consumption by larvae of the intertidal porcelain crab Petrolisthes cinctipes when exposed to subsequent salinity stress. Such an exposure mimics how larvae under future acidified conditions will likely experience sudden runoff events such as those that occur seasonally along portions of the west coast of the U.S. and in other temperate systems, or how larvae encounter hypersaline waters when crossing density gradients via directed swimming. We raised larvae in the laboratory under ambient and predicted future pCO2 levels (385 and 1000 µatm) for 10 days, and then moved them to seawater at ambient pCO2 but with decreased, ambient, or elevated salinity, to monitor their respiration. While larvae raised under elevated pCO2 or exposed to stressful salinity conditions alone did not exhibit higher respiration rates than larvae held in ambient conditions, larvae exposed to elevated pCO2 followed by stressful salinity conditions consumed more oxygen. These results show that even when multiple stressors act sequentially rather than simultaneously, they can retain their capacity to detrimentally affect organisms.

  9. [Influence of all-ceramic and porcelain-fused-to-metal restorations on peri-implant gingival discoloration:a spectrophotometric comparison].

    PubMed

    Peng, Min; Fei, Wei; Mandana, Hosseini; Klaus, Gotfredsen

    2013-04-01

    To compare the gingival discoloration of implant supported all-ceramic and porcelain-fused-to-metal (PFM) restorations in anterior maxillary region by spectrophotometric evaluation. Eighteen patients with 29 implant-supported single crowns (11 all-ceramic restorations, 9 PFM restorations with titanium abutment and 9 PFM restorations with golden alloy abutment) in anterior maxillary area were recruited. The color difference between peri-implant gingiva and contra-lateral/neighboring mucosa was assessed using a spectrophotometer in CIELab coordinates. Subjective gingival discoloration scores were evaluated by clinician. SPSS17.0 software package was used to analyze the data. There was no significant difference between all-ceramic group (3.4±1.8) and PFM group (4.9±3.4) spectrophotometrically. No significant difference was found between all-ceramic restorations and PFM restorations with titanium abutment (3.5±2.5), and no significant difference was found between PFM restorations with titanium abutment and PFM restorations with gold alloy abutment (6.3±3.8) either. There was, however, significant difference between all-ceramic restorations and PFM restorations with gold alloy abutment (P=0.037). There was no significant difference between all-ceramic group and PFM group regarding the clinical gingival discoloration score (GDS), and this gingival discoloration score was found to have significant correlation with the spectrophotometric evaluation (rs=0.426, P=0.021). There is no significant difference between all-ceramic group and PFM group as regard to both spectrophotometric and clinical evaluation of gingival discoloration, but the PFM restorations with gold alloy abutment induce significantly higher discoloration than all-ceramic restorations.

  10. Molecular phylogeny of porcelain crabs (Porcellanidae: Petrolisthes and allies) from the south eastern Pacific: the genera Allopetrolisthes and Liopetrolisthes are not natural entities

    PubMed Central

    2016-01-01

    Porcelain crabs from the closely related genera Petrolisthes, Liopetrolisthes, and Allopetrolisthes are known for their diversity of lifestyles, habitats, and coloration. The evolutionary relationships among the species belonging to these three genera is not fully resolved. A molecular phylogeny of the group may help to resolve the long-standing taxonomic question about the validity of the genera Allopetrolisthes and Liopetrolisthes. Using both ‘total evidence’ and single-marker analyses based on a 362-bp alignment of the 16S rRNA mitochondrial DNA and a 328-bp alignment of the Histone 3 nuclear DNA, the phylogenetic relationships among 11 species from Petrolisthes (6 species), Liopetrolisthes (2 species), and Allopetrolisthes (3 species), all native to the south eastern Pacific, were examined. The analyses supported three pairs of sister species: L. mitra + L. patagonicus, P. tuberculatus + P. tuberculosus, and A. angulosus + A. punctatus. No complete segregation of species, according to genera, was evident from tree topologies. Bayesian-factor analyses revealed strong support for the unconstrained tree instead of an alternative tree in which monophyly of the three genera was forced. Thus, the present molecular phylogeny does not support the separation of the species within this complex into the genera Petrolisthes, Liopetrolisthes, and Allopetrolisthes. Taking into account the above and other recent molecular phylogenetic analyses focused on other representatives from the family Porcellanidae, it is tentatively proposed to eliminate the genera Liopetrolisthes and Allopetrolisthes, and to transfer their members to the genus Petrolisthes. PMID:26989636

  11. Effect of Elevated pCO2 on Metabolic Responses of Porcelain Crab (Petrolisthes cinctipes) Larvae Exposed to Subsequent Salinity Stress

    PubMed Central

    Miller, Seth H.; Zarate, Sonia; Smith, Edmund H.; Gaylord, Brian; Hosfelt, Jessica D.; Hill, Tessa M.

    2014-01-01

    Future climate change is predicted to alter the physical characteristics of oceans and estuaries, including pH, temperature, oxygen, and salinity. Investigating how species react to the influence of such multiple stressors is crucial for assessing how future environmental change will alter marine ecosystems. The timing of multiple stressors can also be important, since in some cases stressors arise simultaneously, while in others they occur in rapid succession. In this study, we investigated the effects of elevated pCO2 on oxygen consumption by larvae of the intertidal porcelain crab Petrolisthes cinctipes when exposed to subsequent salinity stress. Such an exposure mimics how larvae under future acidified conditions will likely experience sudden runoff events such as those that occur seasonally along portions of the west coast of the U.S. and in other temperate systems, or how larvae encounter hypersaline waters when crossing density gradients via directed swimming. We raised larvae in the laboratory under ambient and predicted future pCO2 levels (385 and 1000 µatm) for 10 days, and then moved them to seawater at ambient pCO2 but with decreased, ambient, or elevated salinity, to monitor their respiration. While larvae raised under elevated pCO2 or exposed to stressful salinity conditions alone did not exhibit higher respiration rates than larvae held in ambient conditions, larvae exposed to elevated pCO2 followed by stressful salinity conditions consumed more oxygen. These results show that even when multiple stressors act sequentially rather than simultaneously, they can retain their capacity to detrimentally affect organisms. PMID:25295878

  12. Influence of low concentration acid treatment on lithium disilicate core/veneer ceramic bond strength

    PubMed Central

    Garcia, Rudan P.; Conti, Paulo CR.; Pereira, Jefferson R.; Valle, Accácio Ld.

    2013-01-01

    Objective: This study evaluated the influence of low concentration acid treatment on the shear bond strength between lithium disilicate (LD) infrastructure and veneering porcelain. The surface morphology characteristic after this acid treatment was also examined. Study Design: LD reinforced ceramic cylinders (n=10) (IPS e.max Press, Ivoclar-Vivadent, Schaan, Liechtenstein) were treated (LD-treated) with a low concentration acid solution (Invex Liquid – Ivoclar-Vivadent, Schaan, Liechtenstein) or not treated with the acid solution (LD-untreated). They were veneered with a glass ceramic (IPS e.max Ceram, Ivoclar-Vivadent, Schaan, Liechtenstein). A metal ceramic group (CoCr) was tested as control. Shear bond strength (SBS) was conducted using a universal testing machine at 0.5 mm/min. Surface morphology characteristics after acid treatment were analyzed using scanning electron microscopy. Results: The acid treatment at low concentrations did not influence the SBS of the LD/veneering porcelain interface. The CoCr group showed the significant higher SBS value (35.59 ± 5.97 MPa), followed by LD-untreated group (27.76 ± 3.59 MPa) and LD-treated (27.02 ± 4.79 MPa). The fracture modes were predominantly adhesive for CoCr group and cohesive within the infrastructure for DL groups. Scanning Electron Microscopy (SEM) analysis showed no morphological differences between treated and untreated LD surfaces. Conclusions: Low concentration acid treatment did not improved SBS of veneering ceramic to LD and did not cause morphological changes on the LD surface. Key words:Lithium disilicate, glass ceramics, acid etching, shear bond strength, scanning electron microscopy. PMID:24455073

  13. Effect of processing induced particle alignment on the fracture toughness and fracture behavior of multiphase dental ceramics.

    PubMed

    Gonzaga, Carla C; Okada, Cristina Yuri; Cesar, Paulo F; Miranda, Walter G; Yoshimura, Humberto N

    2009-11-01

    To investigate the processing induced particle alignment on fracture behavior of four multiphase dental ceramics (one porcelain, two glass-ceramics and a glass-infiltrated-alumina composite). Disks (Ø12 mm x 1.1mm-thick) and bars (3 mm x 4 mm x 20 mm) of each material were processed according to manufacturer instructions, machined and polished. Fracture toughness (K(Ic)) was determined by the indentation strength method using 3-point bending and biaxial flexure fixtures for the fracture of bars and disks, respectively. Microstructural and fractographic analyses were performed with scanning electron microscopy, energy dispersive spectroscopy and X-ray diffraction. The isotropic microstructure of the porcelain and the leucite-based glass-ceramic resulted in similar fracture toughness values regardless of the specimen geometry. On the other hand, materials containing second-phase particles with high aspect ratio (lithium disilicate glass-ceramic and glass-infiltrated-alumina composite) showed lower fracture toughness for disk specimens compared to bars. For the lithium disilicate glass-ceramic disks, it was demonstrated that the occurrence of particle alignment during the heat-pressing procedure resulted in an unfavorable pattern that created weak microstructural paths during the biaxial test. For the glass-infiltrated-alumina composite, the microstructural analysis showed that the large alumina platelets tended to align their large surfaces perpendicularly to the direction of particle deposition during slip casting of green preforms. The fracture toughness of dental ceramics with anisotropic microstructure should be determined by means of biaxial testing, since it results in lower values.

  14. Effect of bleaching on microhardness of esthetic restorative materials.

    PubMed

    Malkondu, Özlem; Yurdagüven, Haktan; Say, Esra Can; Kazazoğlu, Ender; Soyman, Mübin

    2011-01-01

    This study evaluated the effect of a high-concentration carbamide peroxide–containing home bleaching system (Opalescence PF) and a hydrogen peroxide–containing over-the-counter bleaching system (Treswhite Supreme) on the microhardness of two nanocomposites (Filtek Supreme XT and Premise) and leucite-reinforced glass ceramic (Empress Esthetic), glass ceramic (Empress 2 layering), and feldspathic porcelain (Matchmaker MC). A total of 100 specimens, 20 of each kind of the restorative materials, 2 mm in thickness and 10 mm in diameter, were fabricated. Then the specimens were polished with SiC paper and 1 μm alumina polishing paste. After polishing, porcelain specimens were glazed in accordance with the manufacturer's instructions. Each type of restorative material was then randomly divided into two groups (n=10), and the specimens were treated with either Opalescence PF or Treswhite Supreme. The microhardness of the specimens before bleaching (baseline) and after bleaching was determined using a digital microhardness tester. Data were analyzed using the Mann-Whitney U-test and the Wilcoxon test. Opalescence PF significantly influenced the hardness of all the restorative materials. Statistically significant decreases with respect to before bleaching were found for Premise (p=0.005), Empress Esthetic (p=0.003), Empress 2 layering (p=0.005), and Matchmaker-MC (p=0.003), whereas a statistically significant increase was observed in Filtek Supreme XT (p=0.028). The difference in the microhardness values between before and after bleaching using Treswhite Supreme was statistically significant only for Premise (p=0.022). High-concentration carbamide peroxide–containing home bleaching may affect the microhardness of restorative materials.

  15. X-ray diffraction analysis of residual stress in zirconia dental composites

    NASA Astrophysics Data System (ADS)

    Allahkarami, Masoud

    Dental restoration ceramic is a complex system to be characterized. Beside its essential biocompatibility, and pleasant appearance, it requires being mechanically strong in a catastrophic loading environment. Any design is restricted with geometry boundary and material property limits. Inspired by natural teeth, a multilayer ceramic is a smart way of achieving an enhanced restoration. Bi-layers of zirconia core covered by porcelain are known as one of the best multilayer restorations. Residual stresses may be introduced into a bi-layer dental ceramic restoration during its entire manufacturing process due to thermal expansion and elastic property mismatch. It is impossible to achieve a free of residual stresses bi-layer zirconia-porcelain restoration. The idea is to take the advantage of residual stress in design in such a way to prevent the crack initiation and progression. The hypothesis is a compressive residual stress at external contact surface would be enabling the restoration to endure a greater tensile stress. Optimizing the layers thickness, manufacturing process, and validating 3D simulations require development of new techniques of thickness, residual stresses and phase transformation measurement. In the present work, a combined mirco-tomography and finite element based method were adapted for thickness measurement. Two new 2D X-ray diffraction based techniques were adapted for phase transformation area mapping and combined phase transformation and residual stress measurement. Concerning the complex geometry of crown, an efficient method for X-ray diffraction data collection mapping on a given curved surface was developed. Finally a novel method for 3D dimensional x-ray diffraction data collection and visualization were introduced.

  16. Effect of framework material and vertical misfit on stress distribution in implant-supported partial prosthesis under load application: 3-D finite element analysis.

    PubMed

    Bacchi, Ataís; Consani, Rafael Leonardo Xediek; Mesquita, Marcelo Ferraz; Dos Santos, Mateus Bertolini Fernandes

    2013-09-01

    This study evaluated the influence of framework material and vertical misfit on stress created in an implant-supported partial prosthesis under load application. The posterior part of a severely reabsorbed jaw with a fixed partial prosthesis above two osseointegrated titanium implants at the place of the second premolar and second molar was modeled using SolidWorks 2010 software. Finite element models were obtained by importing the solid model into an ANSYS Workbench 11 simulation. The models were divided into 15 groups according to their prosthetic framework material (type IV gold alloy, silver-palladium alloy, commercially pure titanium, cobalt-chromium alloy or zirconia) and vertical misfit level (10 µm, 50 µm and 100 µm). After settlement of the prosthesis with the closure of the misfit, simultaneous loads of 110 N vertical and 15 N horizontal were applied on the occlusal and lingual faces of each tooth, respectively. The data was evaluated using Maximum Principal Stress (framework, porcelain veneer and bone tissue) and a von Mises Stress (retention screw) provided by the software. As a result, stiffer frameworks presented higher stress concentrations; however, these frameworks led to lower stresses in the porcelain veneer, the retention screw (faced to 10 µm and 50 µm of the misfit) and the peri-implant bone tissues. The increase in the vertical misfit resulted in stress values increasing in all of the prosthetic structures and peri-implant bone tissues. The framework material and vertical misfit level presented a relevant influence on the stresses for all of the structures evaluated.

  17. Interface toughness of a zirconia-veneer system and the effect of a liner application.

    PubMed

    Wang, Gaoqi; Zhang, Song; Bian, Cuirong; Kong, Hui

    2014-09-01

    Chipping of veneering porcelain and delamination of a zirconia-veneer interface are 2 common clinical failure modes for zirconia-based restorations and may be partially due to weak interface bonding. The effect of liner on the bond strength of the interface has not been clearly identified. The purpose of the research was to evaluate the interface toughness between the zirconia core and veneering porcelain by means of a fracture mechanics test and to assess the effect of liner on the bond strength of the interface. Thirty bilayered beam-shape specimens were prepared and divided into 2 groups according to liner application. The specimens in each group were subdivided into 3 subgroups in accordance with 3 different veneer thicknesses. A fracture mechanics test was used on each specimen, and the energy release rate, G, and phase angle, ψ, were calculated according to the experimental results. A video microscope was used to monitor the crack propagation, and a scanning electron microscope was used to identify the fracture mode after testing. Two-way ANOVA and the Tukey honestly significant difference test were performed to analyze the experimental data (α=.05) . At each phase angle, the interfaces without a liner had higher mean G values than the interfaces with a liner. Both of the interfaces showed mixed failure mode with thin layers of a veneer or a liner that remained on the zirconia surfaces. Liner application before veneering reduced the interface toughness between zirconia and veneer. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Comparison of hospital room surface disinfection using a novel ultraviolet germicidal irradiation (UVGI) generator.

    PubMed

    Jelden, Katelyn C; Gibbs, Shawn G; Smith, Philip W; Hewlett, Angela L; Iwen, Peter C; Schmid, Kendra K; Lowe, John J

    2016-09-01

    The estimated 721,800 hospital acquired infections per year in the United States have necessitated development of novel environmental decontamination technologies such as ultraviolet germicidal irradiation (UVGI). This study evaluated the efficacy of a novel, portable UVGI generator (the TORCH, ChlorDiSys Solutions, Inc., Lebanon, NJ) to disinfect surface coupons composed of plastic from a bedrail, stainless steel, chrome-plated light switch cover, and a porcelain tile that were inoculated with methicillin-resistant Staphylococcus aureus (MRSA) or vancomycin-resistant Enterococcus faecalis (VRE). Each surface type was placed at 6 different sites within a hospital room and treated by 10-min ultraviolet-C (UVC) exposures using the TORCH with doses ranging from 0-688 mJ/cm(2) between sites. Organism reductions were compared with untreated surface coupons as controls. Overall, UVGI significantly reduced MRSA by an average of 4.6 log10 (GSD: 1.7 log10, 77% inactivation, p < 0.0001) and VRE by an average of 3.9 log10 (GSD: 1.7 log10, 65% inactivation, p < 0.0001). MRSA on bedrail was reduced significantly (p < 0.0001) less than on other surfaces, while VRE was reduced significantly less on chrome (p = 0.0004) and stainless steel (p = 0.0012) than porcelain tile. Organisms out of direct line of sight of the UVC generator were reduced significantly less (p < 0.0001) than those directly in line of sight. UVGI was found an effective method to inactivate nosocomial pathogens on surfaces evaluated within the hospital environment in direct line of sight of UVGI treatment with variation between organism and surface types.

  19. The Modulus of Rupture from a Mathematical Point of View

    NASA Astrophysics Data System (ADS)

    Quintela, P.; Sánchez, M. T.

    2007-04-01

    The goal of this work is to present a complete mathematical study about the three-point bending experiments and the modulus of rupture of brittle materials. We will present the mathematical model associated to three-point bending experiments and we will use the asymptotic expansion method to obtain a new formula to calculate the modulus of rupture. We will compare the modulus of rupture of porcelain obtained with the previous formula with that obtained by using the classic theoretical formula. Finally, we will also present one and three-dimensional numerical simulations to compute the modulus of rupture.

  20. Parametric test of a zirconium (4) oxide-polyacrylic acid dual layer hyperfiltration membrane with spacecraft washwater

    NASA Technical Reports Server (NTRS)

    Brandon, C. A.; Gaddis, J. L.; El-Nashar, A. M.

    1975-01-01

    Performance data consisting of solute rejections and product flux were measured, as dependent on the operation parameters. These parameters and ranges were pressure (500,000 n/m2 to 700,000 n/m2), temperature (74 C to 95 C), velocity (1.6 M/sec to 10 M/sec), and concentration (up to 14x). Tests were carried out on analog washwater. Data presented include rejections of organic materials, ammonia, urea, and an assortment of ions. The membrane used was deposited in situ on a porcelain ceramic substrate.

Top