Science.gov

Sample records for portable consumer electronics

  1. NAFFS: network attached flash file system for cloud storage on portable consumer electronics

    NASA Astrophysics Data System (ADS)

    Han, Lin; Huang, Hao; Xie, Changsheng

    Cloud storage technology has become a research hotspot in recent years, while the existing cloud storage services are mainly designed for data storage needs with stable high speed Internet connection. Mobile Internet connections are often unstable and the speed is relatively low. These native features of mobile Internet limit the use of cloud storage in portable consumer electronics. The Network Attached Flash File System (NAFFS) presented the idea of taking the portable device built-in NAND flash memory as the front-end cache of virtualized cloud storage device. Modern portable devices with Internet connection have built-in more than 1GB NAND Flash, which is quite enough for daily data storage. The data transfer rate of NAND flash device is much higher than mobile Internet connections[1], and its non-volatile feature makes it very suitable as the cache device of Internet cloud storage on portable device, which often have unstable power supply and intermittent Internet connection. In the present work, NAFFS is evaluated with several benchmarks, and its performance is compared with traditional network attached file systems, such as NFS. Our evaluation results indicate that the NAFFS achieves an average accessing speed of 3.38MB/s, which is about 3 times faster than directly accessing cloud storage by mobile Internet connection, and offers a more stable interface than that of directly using cloud storage API. Unstable Internet connection and sudden power off condition are tolerable, and no data in cache will be lost in such situation.

  2. Silicon Based Solid Oxide Fuel Cell Chip for Portable Consumer Electronics -- Final Technical Report

    SciTech Connect

    Alan Ludwiszewski

    2009-06-29

    LSI’s fuel cell uses efficient Solid Oxide Fuel Cell (“SOFC”) technology, is manufactured using Micro Electrical Mechanical System (“MEMS”) fabrication methods, and runs on high energy fuels, such as butane and ethanol. The company’s Fuel Cell on a Chip™ technology enables a form-factor battery replacement for portable electronic devices that has the potential to provide an order-of-magnitude run-time improvement over current batteries. Further, the technology is clean and environmentally-friendly. This Department of Energy funded project focused on accelerating the commercialization and market introduction of this technology through improvements in fuel cell chip power output, lifetime, and manufacturability.

  3. Architectural innovation foresight of thermoelectric generator charger integrated portable power supply for portable consumer electronic device in metropolitan market: The case study of Thailand

    NASA Astrophysics Data System (ADS)

    Maolikul, S.; Kiatgamolchai, S.; Chavarnakul, T.

    2012-06-01

    In the context of information and communication technology (ICT) trend for worldwide individuals, social life becomes digital and portable consumer electronic devices (PCED) powered by conventional power supply from batteries have been evolving through miniaturization and various function integration. Thermoelectric generators (TEG) were hypothesized for its potential role of battery charger to serve the shining PCED market. Hence, this paper, mainly focusing at the metropolitan market in Thailand, aimed to conduct architectural innovation foresight and to develop scenarios on potential exploitation approach of PCED battery power supply with TEG charger converting power from ambient heat source adjacent to individual's daily life. After technical review and assessment for TEG potential and battery aspect, the business research was conducted to analyze PCED consumer behavior for their PCED utilization pattern, power supply lack problems, and encountering heat sources/sinks in 3 modes: daily life, work, and leisure hobbies. Based on the secondary data analysis from literature and National Statistical Office of Thailand, quantitative analysis was applied using the cluster probability sampling methodology, statistically, with the sample size of 400 at 0.05 level of significance. In addition, the qualitative analysis was conducted to emphasize the rationale of consumer's behavior using in-depth qualitative interview. Scenario planning technique was also used to generate technological and market trend foresight. Innovation field and potential scenario for matching technology with market was proposed in this paper. The ingredient for successful commercialization of battery power supply with TEG charger for PCED market consists of 5 factors as follows: (1) PCED characteristic, (2) potential ambient heat sources/sinks, (3) battery module, (4) power management module, and the final jigsaw (5) characteristic and adequate arrangement of TEG modules. The foresight outcome for

  4. Trust in Consumer Electronics

    NASA Astrophysics Data System (ADS)

    Kursawe, Klaus; Katzenbeisser, Stefan

    While Trusted Computing is getting increasing attention in the PC world, consumer electronics devices have limited benefit from the Trusted Computing solutions currently under development. In this paper we outline the different requirements of consumer electronics devices, when compared to the PC world, and point out the technical consequences for standards like the Trusted Computing Group. In addition, we will touch on economic aspects that may inhibit or support Trusted Computing in this domain.

  5. Portable electronic endoscopic imaging system

    NASA Astrophysics Data System (ADS)

    Du, Lihui; Wang, Liqiang; Ye, Bin; Duan, Huilong

    2010-11-01

    The paper presents a low-power, inexpensive and portable endoscopic imaging system. A 1.3 million pixels CMOS sensor is considered as an image capture. The sensor and the lens system are designed to minify the cannula diameter of the endoscope and therefore minimize the incision size for insertion. LVDS is used for image data transmission between the sensor and CPU to realize a long distance, high speed and low noise system. An ARM 920T based microcontroller is employed as the control core for the image transmission module, display module and other modules. The camera interface and LCD controller are integrated in the microcontroller and both have a dedicated DMA supports to transmit image data though AHB to or from frame buffer located in system memory without CPU intervention. The image is displayed on an 8 inch LCD screen with 800 × 600 resolution and 16 bits of color depth. With the maximum capture and display rate of 15 fps, this system can provide a clear image enough for laparoscopy or industrial application. And with integrated camera, light source and video display function, it can also be used as a portable, miniature and inexpensive endoscope.

  6. 14 CFR 135.144 - Portable electronic devices.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Portable electronic devices. 135.144... Equipment § 135.144 Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no... portable electronic device on any of the following U.S.-registered civil aircraft operating under this part...

  7. 14 CFR 125.204 - Portable electronic devices.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Portable electronic devices. 125.204... Equipment Requirements § 125.204 Portable electronic devices. (a) Except as provided in paragraph (b) of... operation of, any portable electronic device on any U.S.-registered civil aircraft operating under this part...

  8. 14 CFR 125.204 - Portable electronic devices.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Portable electronic devices. 125.204... Equipment Requirements § 125.204 Portable electronic devices. (a) Except as provided in paragraph (b) of... operation of, any portable electronic device on any U.S.-registered civil aircraft operating under this part...

  9. 14 CFR 135.144 - Portable electronic devices.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Portable electronic devices. 135.144... Equipment § 135.144 Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no... portable electronic device on any of the following U.S.-registered civil aircraft operating under this part...

  10. 14 CFR 125.204 - Portable electronic devices.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Portable electronic devices. 125.204... Equipment Requirements § 125.204 Portable electronic devices. (a) Except as provided in paragraph (b) of... operation of, any portable electronic device on any U.S.-registered civil aircraft operating under this part...

  11. 14 CFR 135.144 - Portable electronic devices.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Portable electronic devices. 135.144... Equipment § 135.144 Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no... portable electronic device on any of the following U.S.-registered civil aircraft operating under this part...

  12. 14 CFR 125.204 - Portable electronic devices.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Portable electronic devices. 125.204... Equipment Requirements § 125.204 Portable electronic devices. (a) Except as provided in paragraph (b) of... operation of, any portable electronic device on any U.S.-registered civil aircraft operating under this part...

  13. 14 CFR 135.144 - Portable electronic devices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Portable electronic devices. 135.144... Equipment § 135.144 Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no... portable electronic device on any of the following U.S.-registered civil aircraft operating under this part...

  14. 14 CFR 135.144 - Portable electronic devices.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Portable electronic devices. 135.144... Equipment § 135.144 Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no... portable electronic device on any of the following U.S.-registered civil aircraft operating under this part...

  15. 14 CFR 125.204 - Portable electronic devices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Portable electronic devices. 125.204... Equipment Requirements § 125.204 Portable electronic devices. (a) Except as provided in paragraph (b) of... operation of, any portable electronic device on any U.S.-registered civil aircraft operating under this part...

  16. 14 CFR 91.21 - Portable electronic devices.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...

  17. 14 CFR 91.21 - Portable electronic devices.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...

  18. 14 CFR 121.306 - Portable electronic devices.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Portable electronic devices. 121.306... Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate... electronic device on any U.S.-registered civil aircraft operating under this part. (b) Paragraph (a) of this...

  19. 14 CFR 121.306 - Portable electronic devices.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Portable electronic devices. 121.306... Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate... electronic device on any U.S.-registered civil aircraft operating under this part. (b) Paragraph (a) of this...

  20. 14 CFR 121.306 - Portable electronic devices.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Portable electronic devices. 121.306... Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate... electronic device on any U.S.-registered civil aircraft operating under this part. (b) Paragraph (a) of this...

  1. 14 CFR 91.21 - Portable electronic devices.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...

  2. 14 CFR 91.21 - Portable electronic devices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...

  3. 14 CFR 91.21 - Portable electronic devices.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...

  4. 14 CFR 121.306 - Portable electronic devices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Portable electronic devices. 121.306... Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate... electronic device on any U.S.-registered civil aircraft operating under this part. (b) Paragraph (a) of this...

  5. 14 CFR 121.306 - Portable electronic devices.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Portable electronic devices. 121.306... Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate... electronic device on any U.S.-registered civil aircraft operating under this part. (b) Paragraph (a) of this...

  6. 78 FR 38361 - Certain Portable Electronic Communications Devices, Including Mobile Phones and Components...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-26

    ... COMMISSION Certain Portable Electronic Communications Devices, Including Mobile Phones and Components Thereof... States after importation of certain portable electronic ] communications devices, including mobile phones... importation of certain portable electronic communications devices, including mobile phones and components...

  7. 78 FR 34669 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-10

    ... COMMISSION Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data..., California (``Apple''), from importing wireless communication devices, portable music and data processing... importation of certain electronic devices, including wireless communication devices, portable music and data...

  8. Portable Cytometry Using Microscale Electronic Sensing

    PubMed Central

    Emaminejad, Sam; Paik, Kee-Hyun; Tabard-Cossa, Vincent; Javanmard, Mehdi

    2015-01-01

    In this manuscript, we present three different micro-impedance sensing architectures for electronic counting of cells and beads. The first method of sensing is based on using an open circuit sensing electrode integrated in a micro-pore, which measures the shift in potential as a micron-sized particle passes through. Our micro-pore, based on a funnel shaped microchannel, was fabricated in PDMS and was bound covalently to a glass substrate patterned with a gold open circuit electrode. The amplification circuitry was integrated onto a battery-powered custom printed circuit board. The second method is based on a three electrode differential measurement, which opens up the potential of using signal processing techniques to increase signal to noise ratio post measurement. The third architecture uses a contactless sensing approach, which significantly minimizes the cost of the consumable component of the impedance cytometer. We demonstrated proof of concept for the three sensing architectures by measuring the detected signal due to the passage of micron sized beads through the pore. PMID:27647950

  9. Lighnting detection and tracking with consumer electronics

    NASA Astrophysics Data System (ADS)

    Kamau, Gilbert; van de Giesen, Nick

    2015-04-01

    Lightning data is not only important for environment and weather monitoring but also for safety purposes. The AS3935 Franklin Lightning Sensor (AMS, Unterpremstaetten, Austria) is a lightning sensor developed for inclusion in consumer electronics such as watches and mobile phones. The AS3935 is small (4mmx4mm) and relatively cost effective (Eu 5). The downside is that only rough distance estimates are provided, as average power is assumed for every lightning strike. To be able to track lightning, a network of devices that monitor and keep track of occurrences of lightning strikes was developed. A communication interface was established between the sensors, a data logging circuit and a microcontroller. The digital outputs of the lightning sensor and data from a GPS are processed by the microcontroller and logged onto an SD card. The interface program enables sampling parameters such as distance from the lightning strike, time of strike occurrence and geographical location of the device. For archiving and analysis purposes, the data can be transferred from the SD card to a PC and results displayed using a graphical user interface program. Data gathered shows that the device can track the frequency and movement of lightning strikes in an area. The device has many advantages as compared to other lightning sensor stations in terms of huge memory, lower power consumption, small size, greater portability and lower cost. The devices were used in a network around Nairobi, Kenya. Through multi-lateration, lightning strikes could be located with a RMSE of 2 km or better.

  10. Preliminary Design and Evaluation of Portable Electronic Flight Progress Strips

    NASA Technical Reports Server (NTRS)

    Doble, Nathan A.; Hansman, R. John

    2002-01-01

    There has been growing interest in using electronic alternatives to the paper Flight Progress Strip (FPS) for air traffic control. However, most research has been centered on radar-based control environments, and has not considered the unique operational needs of the airport air traffic control tower. Based on an analysis of the human factors issues for control tower Decision Support Tool (DST) interfaces, a requirement has been identified for an interaction mechanism which replicates the advantages of the paper FPS (e.g., head-up operation, portability) but also enables input and output with DSTs. An approach has been developed which uses a Portable Electronic FPS that has attributes of both a paper strip and an electronic strip. The prototype flight strip system uses Personal Digital Assistants (PDAs) to replace individual paper strips in addition to a central management interface which is displayed on a desktop computer. Each PDA is connected to the management interface via a wireless local area network. The Portable Electronic FPSs replicate the core functionality of paper flight strips and have additional features which provide a heads-up interface to a DST. A departure DST is used as a motivating example. The central management interface is used for aircraft scheduling and sequencing and provides an overview of airport departure operations. This paper will present the design of the Portable Electronic FPS system as well as preliminary evaluation results.

  11. TECHNICAL NOTE: Portable audio electronics for impedance-based measurements in microfluidics

    NASA Astrophysics Data System (ADS)

    Wood, Paul; Sinton, David

    2010-08-01

    We demonstrate the use of audio electronics-based signals to perform on-chip electrochemical measurements. Cell phones and portable music players are examples of consumer electronics that are easily operated and are ubiquitous worldwide. Audio output (play) and input (record) signals are voltage based and contain frequency and amplitude information. A cell phone, laptop soundcard and two compact audio players are compared with respect to frequency response; the laptop soundcard provides the most uniform frequency response, while the cell phone performance is found to be insufficient. The audio signals in the common portable music players and laptop soundcard operate in the range of 20 Hz to 20 kHz and are found to be applicable, as voltage input and output signals, to impedance-based electrochemical measurements in microfluidic systems. Validated impedance-based measurements of concentration (0.1-50 mM), flow rate (2-120 µL min-1) and particle detection (32 µm diameter) are demonstrated. The prevailing, lossless, wave audio file format is found to be suitable for data transmission to and from external sources, such as a centralized lab, and the cost of all hardware (in addition to audio devices) is ~10 USD. The utility demonstrated here, in combination with the ubiquitous nature of portable audio electronics, presents new opportunities for impedance-based measurements in portable microfluidic systems.

  12. 78 FR 16865 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-19

    ... COMMISSION Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers; Investigations: Terminations, Modifications and Rulings AGENCY: U.S... importation of certain electronic devices, including wireless communication devices, portable music and data...

  13. 78 FR 32689 - Certain Portable Electronic Communications Devices, Including Mobile Phones and Components...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-31

    ... COMMISSION Certain Portable Electronic Communications Devices, Including Mobile Phones and Components Thereof... communications devices, including mobile phones and components thereof. The complaint names as respondents HTC... Trade Commission has received a complaint entitled Certain Portable Electronic Communications Devices...

  14. Portable radiography system using a relativistic electron beam

    DOEpatents

    Hoeberling, Robert F.

    1990-01-01

    A portable radiographic generator is provided with an explosive magnetic flux compression generator producing the high voltage necessary to generate a relativistic electron beam. The relativistic electron beam is provided with target materials which generates the desired radiographic pulse. The magnetic flux compression generator may require at least two conventional explosively driven generators in series to obtain a desired output voltage of at least 1 MV. The cathode and anode configuration of the diode are selected to provide a switching action wherein a high impedance load is presented to the magnetic flux compression generator when the high voltage is being generated, and thereafter switching to a low impedance load to generate the relativistic electron beam. Magnetic flux compression generators can be explosively driven and provided in a relatively compact, portable form for use with the relativistic x-ray equipment.

  15. Portable radiography system using a relativistic electron beam

    DOEpatents

    Hoeberling, R.F.

    1987-09-22

    A portable radiographic generator is provided with an explosive magnetic flux compression generator producing the high voltage necessary to generate a relativistic electron beam. The relativistic electron beam is provided with target materials which generates the desired radiographic pulse. The magnetic flux compression generator may require at least two conventional explosively driven generators in series to obtain a desired output voltage of at least 1 MV. The cathode and anode configuration of the diode are selected to provide a switching action wherein a high impedance load is presented to the magnetic flux compression generator when the high voltage is being generated, and thereafter switching to a low impedance load to generate the relativistic electron beam. Magnetic flux compression generators can be explosively driven and provided in a relatively compact, portable form for use with the relativistic x-ray equipment. 8 figs.

  16. Triboelectric nanogenerator for powering portable electronics

    DOEpatents

    Wang, Zhong Lin; Wang, Sihong; Lin, Long; Zhu, Guang; Lin, Zong-Hong

    2017-03-14

    A triboelectric generator includes a first contact charging member and a second contact charging member. The first contact charging member includes a first contact layer and a conductive electrode layer. The first contact layer includes a material that has a triboelectric series rating indicating a propensity to gain electrons due to a contacting event. The conductive electrode layer is disposed along the back side of the contact layer. The second contact charging member is spaced apart from and disposed oppositely from the first contact charging member. It includes an electrically conductive material layer that has a triboelectric series rating indicating a propensity to lose electrons when contacted by the first contact layer during the contacting event. The electrically conductive material acts as an electrode. A mechanism maintains a space between the first contact charging member and the second contact charging member except when a force is applied thereto.

  17. 76 FR 50253 - Certain Portable Electronic Devices and Related Software; Notice of Institution of Investigation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-12

    ... COMMISSION Certain Portable Electronic Devices and Related Software; Notice of Institution of Investigation... certain portable electronic devices and related software by reason of infringement of certain claims of U... portable electronic devices and related software that infringe one or more of claims 1-5, 7-12, 14-19,...

  18. 78 FR 116 - Certain Cases for Portable Electronic Devices: Notice of Receipt of Complaint; Solicitation of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-02

    ... COMMISSION Certain Cases for Portable Electronic Devices: Notice of Receipt of Complaint; Solicitation of... Certain Cases For Portable Electronic Devices, DN 2927; the Commission is soliciting comments on any... importation of certain cases for portable electronic devices. The complaint names as respondents Global...

  19. 78 FR 32442 - Certain Cases for Portable Electronic Devices; Determination Not To Review an Initial...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-30

    ... COMMISSION Certain Cases for Portable Electronic Devices; Determination Not To Review an Initial... sale within the United States after importation of certain cases for portable electronic devices by... portable electronic devices by reason of infringement of various claims of the '561 patent. The complaint...

  20. 78 FR 2437 - Corrected: Certain Cases For Portable Electronic Devices; Notice of Receipt of Complaint...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-11

    ... COMMISSION Corrected: Certain Cases For Portable Electronic Devices; Notice of Receipt of Complaint... complaint entitled Certain Cases For Portable Electronic Devices, DN 2927; the Commission is soliciting... States after importation of certain cases for portable electronic devices. The complaint names as...

  1. Field-portable-XRF reveals the ubiquity of antimony in plastic consumer products.

    PubMed

    Turner, Andrew; Filella, Montserrat

    2017-02-09

    Very little systematic information exists on the occurrence and concentrations of antimony (Sb) in consumer products. In this study, a Niton XL3t field-portable-X-ray fluorescence (FP-XRF) spectrometer was deployed in situ and in the laboratory to provide quantitative information on Sb dissipated in plastic items and fixtures (including rubber, textile and foamed materials) from the domestic, school, vehicular and office settings. The metalloid was detected in 18% of over 800 measurements performed, with concentrations ranging from about 60 to 60,000μgg(-1). The highest concentrations were encountered in white, electronic casings and in association with similar concentrations of Br, consistent with the use of antimony oxides (e.g. Sb2O3) as synergistic flame retardants. Concentrations above 1000μgg(-1), and with or without Br, were also encountered in paints, piping and hosing, adhesives, whiteboards, Christmas decorations, Lego blocks, document carriers, garden furniture, upholstered products and interior panels of private motor vehicles. Lower concentrations of Sb were encountered in a wide variety of items but its presence (without Br) in food tray packaging, single-use drinks bottles, straws and small toys were of greatest concern from a human health perspective. While the latter observations are consistent with the use of antimony compounds as catalysts in the production of polyethylene terephthalate, co-association of Sb and Br in many products not requiring flame retardancy suggests that electronic casings are widely recycled. Further research is required into the mobility of Sb when dissipated in new, recycled and aged polymeric materials.

  2. Electronic Resources for Family and Consumer Sciences.

    ERIC Educational Resources Information Center

    Goldsmith, Elizabeth B.

    1996-01-01

    Describes the following types of electronic resources relevant for family and consumer sciences: online and CD-ROM databases, numeric datafiles, and Internet resources (listservs, telnet sources, gopher/World Wide Web). (SK)

  3. A Portable Electronic Nose For Hydrazine and Monomethyl Hydrazine Detection

    NASA Technical Reports Server (NTRS)

    Young, Rebecca C.; Linnell, Bruce R.; Peterson, Barbara V.; Brooks, Kathy B.; Griffin, Tim P.

    2004-01-01

    The Space Program and military use large quantities Hydrazine (Hz) and monomethyl hydrazine (MMI-I) as rocket propellant. These substances are very toxic and are suspected human carcinogens. The American Conference of Governmental Industrial Hygienist set the threshold limit value to be 10 parts per billion (ppb). Current off-the-shelf portable instruments require 10 to 20 minutes of exposure to detect 10 ppb concentration. This shortcofriing is not acceptable for many operations. A new prototype instrument using a gas sensor array and pattern recognition software technology (i.e., an electronic nose) has demonstrated the ability to identify either Hz or MM}{ and quantify their concentrations at 10 parts per billion in 90 seconds. This paper describes the design of the portable electronic nose (e-nose) instrument, test equipment setup, test protocol, pattern recognition algorithm, concentration estimation method, and laboratory test results.

  4. The use of a portable electronic device in accident dosimetry.

    PubMed

    Beerten, Koen; Vanhavere, Filip

    2008-01-01

    The use of a portable electronic device in accident dosimetry has been investigated. The thermoluminescence properties of a surface-mount alumina-rich ceramic resonator from a USB flash drive were investigated. The following characteristics were verified: the absence of a zero-dose signal, gamma dose response, dose recycling behaviour, fading and optical bleaching. Finally, this component has been successfully used to determine a simulated accident dose (1 d following the irradiation event). It is concluded that it should be possible to perform rapid and reliable accident dose assessments with such components using conventional thermoluminescence dosimetry equipment.

  5. Consumer Electronic Repair. Florida Vocational Program Guide.

    ERIC Educational Resources Information Center

    University of South Florida, Tampa. Dept. of Adult and Vocational Education.

    This program guide identifies primary concerns in the organization, operation, and evaluation of a consumer electronic (radio and television) repair program. It is designed for local school district and community college administrators, instructors, program advisory committees, and regional coordinating councils. The guide begins with the…

  6. 47 CFR 15.118 - Cable ready consumer electronics equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Cable ready consumer electronics equipment. 15... Unintentional Radiators § 15.118 Cable ready consumer electronics equipment. (a) All consumer electronics TV... provisions of this section. Consumer electronics TV receiving equipment that includes features intended...

  7. 47 CFR 15.118 - Cable ready consumer electronics equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Cable ready consumer electronics equipment. 15... Unintentional Radiators § 15.118 Cable ready consumer electronics equipment. (a) All consumer electronics TV... provisions of this section. Consumer electronics TV receiving equipment that includes features intended...

  8. 47 CFR 15.118 - Cable ready consumer electronics equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Cable ready consumer electronics equipment. 15... Unintentional Radiators § 15.118 Cable ready consumer electronics equipment. (a) All consumer electronics TV... provisions of this section. Consumer electronics TV receiving equipment that includes features intended...

  9. 47 CFR 15.118 - Cable ready consumer electronics equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Cable ready consumer electronics equipment. 15... Unintentional Radiators § 15.118 Cable ready consumer electronics equipment. (a) All consumer electronics TV... provisions of this section. Consumer electronics TV receiving equipment that includes features intended...

  10. 47 CFR 15.118 - Cable ready consumer electronics equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Cable ready consumer electronics equipment. 15... Unintentional Radiators § 15.118 Cable ready consumer electronics equipment. (a) All consumer electronics TV... provisions of this section. Consumer electronics TV receiving equipment that includes features intended...

  11. Portable Electron-Beam Free-Form Fabrication System

    NASA Technical Reports Server (NTRS)

    Watson, J. Kevin; Petersen, Daniel D.; Taminger, Karen M.; Hafley, Robert A.

    2005-01-01

    A portable electron-beam free-form fabrication (EB F3) system, now undergoing development, is intended to afford a capability for manufacturing metal parts in nearly net sizes and shapes. Although the development effort is oriented toward the eventual use of systems like this one to supply spare metal parts aboard spacecraft in flight, the basic system design could also be adapted to terrestrial applications in which there are requirements to supply spare parts on demand at locations remote from warehouses and conventional manufacturing facilities. Prior systems that have been considered for satisfying the same requirements (including prior free-form fabrication systems) are not easily portable because of their bulk and massive size. The mechanical properties of the components that such systems produce are often inferior to the mechanical properties of the corresponding original, conventionally fabricated components. In addition, the prior systems are not efficient in the utilization of energy and of feedstock. In contrast, the present developmental system is designed to be sufficiently compact and lightweight to be easily portable, to utilize both energy and material more efficiently, and to produce components that have mechanical properties approximating those of the corresponding original components. The developmental EB F3 system will include a vacuum chamber and associated vacuum pumps, an electron-beam gun and an associated power supply, a multiaxis positioning subsystem, a precise wire feeder, and an instrumentation system for monitoring and control. The electron-beam gun, positioning subsystem, and wire feeder will be located inside the vacuum chamber (see figure). The electron beam gun and the wire feeder will be mounted in fixed positions inside the domed upper portion of the vacuum chamber. The positioning subsystem and ports for the vacuum pumps will be located on a base that could be dropped down to provide full access to the interior of the chamber

  12. 75 FR 4583 - In the Matter of: Certain Electronic Devices, Including Mobile Phones, Portable Music Players...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-28

    ... COMMISSION In the Matter of: Certain Electronic Devices, Including Mobile Phones, Portable Music Players, and... electronic devices, including mobile phones, portable music players, and computers, by reason of infringement... electronic docket (EDIS) at http://edis.usitc.gov . FOR FURTHER INFORMATION CONTACT: Rett Snotherly, Esq...

  13. Cumulative Interference to Aircraft Radios from Multiple Portable Electronic Devices

    NASA Technical Reports Server (NTRS)

    Nguyen, Truong X.

    2005-01-01

    Cumulative interference effects from portable electronic devices (PEDs) located inside a passenger cabin are conservatively estimated for aircraft radio receivers. PEDs' emission powers in an aircraft radio frequency band are first scaled according to their locations' interference path loss (IPL) values, and the results are summed to determine the total interference power. The multiple-equipment-factor (MEF) is determined by normalizing the result against the worst case contribution from a single device. Conservative assumptions were made and MEF calculations were performed for Boeing 737's Localizer, Glide-slope, Traffic Collision Avoidance System, and Very High Frequency Communication radio systems where full-aircraft IPL data were available. The results show MEF for the systems to vary between 10 and 14 dB. The same process was also used on the more popular window/door IPL data, and the comparison show the multiple-equipment-factor results came within one decibel (dB) of each other.

  14. A Portable Sensing System for Electronic Tongue Operations

    PubMed Central

    Twomey, Karen; Truemper, Andreas; Murphy, Kilian

    2006-01-01

    A portable, low cost sensing system is described which interfaces to an electronic tongue sensor. The sensor used is a voltammetric sensor which monitors electrochemical reactions that occur in solutions. The sensor is able to test a range of liquids with different electrochemical properties without any hardware adjustments to the system. The system can automatically adjust for the change in solution properties by performing a routine which uses an auto-ranging feature to determine a current-to-voltage conversion of the sensor data by using a binary search strategy. This eliminates the intervention of the user to modify the system each time a new solution is tested. The effectiveness of the calibration routine was tested by carrying out cyclic voltammetry in two different solutions, 0.1M sulfuric acid solution and the phosphate buffered solution of pH3. The sensor system was able to accurately acquire the sensor data for each solution.

  15. Privacy preservation and information security protection for patients' portable electronic health records.

    PubMed

    Huang, Lu-Chou; Chu, Huei-Chung; Lien, Chung-Yueh; Hsiao, Chia-Hung; Kao, Tsair

    2009-09-01

    As patients face the possibility of copying and keeping their electronic health records (EHRs) through portable storage media, they will encounter new risks to the protection of their private information. In this study, we propose a method to preserve the privacy and security of patients' portable medical records in portable storage media to avoid any inappropriate or unintentional disclosure. Following HIPAA guidelines, the method is designed to protect, recover and verify patient's identifiers in portable EHRs. The results of this study show that our methods are effective in ensuring both information security and privacy preservation for patients through portable storage medium.

  16. Portable Electronic Nose to Discriminate Artificial Aged Wine from Barrel-Aged Wine

    NASA Astrophysics Data System (ADS)

    Santos, J. P.; Cabellos, J. M.; Arroyo, T.; Horrillo, M. C.

    2011-09-01

    A novel portable electronic nose is presented as a fast tool to differentiate traditional aged wines from artificial aged wines. The instrument we have developed for testing the wines is a general purpose wireless portable electronic nose base on micromechanical tin oxide sensors. This system may discriminate among the wine samples obtained with the different aging methods.

  17. 77 FR 11157 - Certain Portable Electronic Devices and Related Software; Final Determination Finding No...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-24

    ... COMMISSION Certain Portable Electronic Devices and Related Software; Final Determination Finding No Violation... software by reason of infringement of various claims of the '800 patent; United States Patent No. 5,541,988... of the accused portable electronic devices and related software. Regarding infringement, the...

  18. 77 FR 60720 - Certain Electronic Devices, Including Wireless Commmunication Devices, Portable Music and Data...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-04

    ... infringing electronic devices, including wireless communication devices, portable music and data processing... COMMISSION Certain Electronic Devices, Including Wireless Commmunication Devices, Portable Music and Data Processing Devices, and Tablet Computers; Notice of Request for Statements on the Public Interest AGENCY: U.S...

  19. 76 FR 24051 - In the Matter of Certain Electronic Devices, Including Mobile Phones, Mobile Tablets, Portable...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-29

    ... importation of certain electronic devices, including mobile phones, mobile tablets, portable music players... COMMISSION In the Matter of Certain Electronic Devices, Including Mobile Phones, Mobile Tablets, Portable Music Players, and Computers, and Components Thereof; Notice of Institution of Investigation AGENCY: U.S...

  20. A method for assessing the potential for a dermal burn hazard from malfunctioning consumer electronic devices.

    PubMed

    Mikolajczak, Celina J; Taylor, Paul M

    2008-01-01

    We developed an approach to adapt the ASTM C1055-03 Standard to assess the potential for contact burn injury from portable consumer electronic devices. The approach involves measuring the maximum temperature profile during the fault and devising a way to reproduce these temperatures in an exemplar device in a controlled manner for thermesthesiometer measurements. By comparing the results of the thermesthesiometer measurements to the contact burn injury threshold data published in ASTM C1055-03 and various guidelines for unintentional contact times, we were able to predict whether a potential hazard exists and verify result with "finger tests." We applied this method on a number of occasions to assess the likelihood of a contact burn injury resulting from a fault arising inside portable consumer electronic devices.

  1. Intelligent consumer-centric electronic medical record.

    PubMed

    Luo, Gang; Thomas, Selena B; Tang, Chunqiang

    2009-01-01

    Web-based, consumer-centric electronic medical records (CEMRs) are currently undergoing widespread deployment. Existing CEMRs, however, have limited intelligence and cannot satisfy users' many needs. This paper proposes the concept of intelligent CEMR. We introduce and extend expert system and web search technology into the CEMR domain. The resulting intelligent CEMRs can automatically provide users with personalized healthcare information to facilitate their daily activities. We use automatic home medical product recommendation as a concrete application to demonstrate the benefits offered by intelligent CEMRs.

  2. A portable electronic system for radiation dosimetry using electrets

    NASA Astrophysics Data System (ADS)

    Cruvinel, P. E.; Mascarenhas, S.; Cameron, J.

    1990-02-01

    An electret dosimeter with a cylindrical active volume has been introduced by Mascarenhas and collaborators [Proc. 10th Anniversary Conf. 1969-1979, Associacâo Brasileira de Fisicos em Medicina, p. 488; Topics Appl. Phys. 33 (1987) 321] for possible use in personnel and area monitoring. The full energy response curve as well as the degree of reproducibility and accuracy of the dosimeter are reported in a previous report [O. Guerrini, Master Science Thesis, São Carlos, USP-IFQSC (1982)]. For dimensions similar to those of the common pen dosimeter, the electret has a total surface charge of the order of 10 -9 C and it has a readout sensitivity of the order of 10 -5 Gy with a useful range of 5 × 10 -2 Gy. In this paper we describe a portable electronic system to measure X and γ-rays using a cylindrical electret ionization chamber. It uses commercially available operational amplifiers, and charge measurements can also be made by connecting a suitable capacitor in the feedback loop. With this system it is possible to measure equivalent surface charges up to (19.99±0.01) on the dosimeter. The readout doses are shown on a 3 {1}/{2} digit liquid crystal display (LCD). We have used complementary metal oxide semiconductor (CMOS) and bipolar metal oxide semiconductor (BiMOS) operatonal amplifier devices in the system's design. This choice provides small power consumption and is ideal for battery powered instruments. Furthermore the instrument is ideally suited for in situ measurements of X and γ radiation using a cylindrical electret ionization chamber.

  3. 78 FR 56737 - Certain Portable Electronic Communications Devices, Including Mobile Phones and Components...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-13

    ... From the Federal Register Online via the Government Publishing Office ] INTERNATIONAL TRADE COMMISSION Certain Portable Electronic Communications Devices, Including Mobile Phones and Components Thereof; Commission Determination Not To Review an Initial Determination Granting Complainant's Motion To Amend the...

  4. 78 FR 72712 - Certain Portable Electronic Communications Devices, Including Mobile Phones and Components...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-03

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Certain Portable Electronic Communications Devices, Including Mobile Phones and Components Thereof; Commission Determination Not To Review an Initial Determination Granting Google, Inc.'s Motion To Intervene...

  5. 78 FR 34132 - Certain Portable Electronic Communications Devices, Including Mobile Phones and Components...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-06

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Certain Portable Electronic Communications Devices, Including Mobile Phones and Components Thereof... Communications Devices, Including Mobile Phones and Components Thereof, DN 2958; the Commission solicited...

  6. 78 FR 49764 - Certain Portable Electronic Communications Devices, Including Mobile Phones and Components...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-15

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Certain Portable Electronic Communications Devices, Including Mobile Phones and Components Thereof; Commission Determination Not To Review n Initial Determination Granting Google, Inc.'s Unopposed Motion To...

  7. HD-DVD: the next consumer electronics revolution?

    NASA Astrophysics Data System (ADS)

    Topiwala, Pankaj N.

    2003-11-01

    The DVD is emerging as one of the world's favorite consumer electronics product, rapidly replacing analog videotape in the US and many other markets at prodigious rates. It is capable of offering a full feature-length, standard-definition movie in crisp rendition on TV. TV technology is itself in the midst of switching from analog to digital TV, with high-definition being the main draw. In fact, the US government has been advocating that switch over to digital TC, with both carrot and stick approaches, for nearly two decades, with only modest results--about 2% penetration. Under FCC herding, broadcasters are falling in the digital line--slowly, and sans profit. Meanwhile, delivery of HD content on portable media would be a great solution. Indeed, a new disk technology based on blue lasers is coming; but its widespread adoption may yet be four to five yeras away. But a promising new video codec--H.264/MPEG-4 AVC, the latest coding standard jointly developed by the Video Coding Experts Group (VCEG) of ITU-T and Moving Picture Experts Group (MPEG) of ISO/IEC, just might be the missing link. It offers substantial coding gains over MPEG-2, used in today's DVDs. With H.264, it appears possible to put HD movies on today's red-laser DVDs. Since consumers love DVDs, and HD--when they can see it, can H.264 and HD-DVD ignite a new revolution, now? It may have a huge impact on (H)DTV adoption rates.

  8. Electronic flow rate controller for a portable insulin infusion pump.

    PubMed

    Ferguson, R T; Zinman, B; Marliss, E B; Albisser, A M

    1980-01-01

    An electronic controller is described that regulates the flow of infusate by controlling the fraction of time that a pump is energized. Using the integral programming capability of the device, any one of 256 possible basal rates between 0 and 49.6% of the maximum rate can be chosen. An externally triggerable single meal-associated pulse can also be configured. The rate during the meal pulse can be any one of the 255 equally spaced rates in the range of 0--99.7%. The duration of this pulse can be chosen in 3-min steps to a maximum of 12.75 h, after which the rate automatically returns to the basal value. The controller consumes a minimum amount of power and can continuously operate a dc motor-driven pump at 3.0 V for 36 h. It drives the pump in an on-off mode in order to control the average flow rate digitally. In this way a significant reduction in the power requirements is realized and the system can be run for many days using small rechargeable batteries. One year of experience with 20 of these controllers was obtained in the research laboratory and clinical investigation unit. The results of this experience indicated the reliability and precision of these controllers, gave insight into their modes of failure, and provided valuable biomedical data for their improvement.

  9. 47 CFR 76.630 - Compatibility with consumer electronics equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Compatibility with consumer electronics... Compatibility with consumer electronics equipment. (a) Cable system operators shall not scramble or otherwise... subscribe to a level of service above “basic only” but use a digital television or other device with a...

  10. 47 CFR 76.630 - Compatibility with consumer electronics equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false Compatibility with consumer electronics... Compatibility with consumer electronics equipment. (a) Cable system operators shall not scramble or otherwise... subscribe to a level of service above “basic only” but use a digital television or other device with a...

  11. 47 CFR 76.630 - Compatibility with consumer electronics equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Compatibility with consumer electronics equipment. 76.630 Section 76.630 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST... Compatibility with consumer electronics equipment. (a) Cable system operators shall not scramble or...

  12. 47 CFR 76.630 - Compatibility with consumer electronics equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Compatibility with consumer electronics equipment. 76.630 Section 76.630 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST... Compatibility with consumer electronics equipment. (a) Cable system operators shall not scramble or...

  13. Emerging Power/Energy Technologies for Portable Electronics for SOCOM

    DTIC Science & Technology

    2008-02-29

    The same is true of portable engines (e.g. Stirling ), and their lower “technology readiness level” can explain inconsistencies between tests. The...thus should be adopted should it meet military standards. Many different types of fuel cell systems are in development for 20 W operation, but, as...energy management for each soldier and operator. • Many different types of fuel cell systems are in development, and many show significant weight

  14. 76 FR 41522 - In the Matter of Certain Electronic Devices, Including Mobile Phones, Mobile Tablets, Portable...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-14

    ... COMMISSION In the Matter of Certain Electronic Devices, Including Mobile Phones, Mobile Tablets, Portable Music Players, and Computers, and Components Thereof; Notice of Commission Decision Not To Review an... public record for this investigation may be viewed on the Commission's electronic docket (EDIS) at http...

  15. 76 FR 40930 - In the Matter of Certain Electronic Devices, Including Mobile Phones, Portable Music Players, and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-12

    ... COMMISSION In the Matter of Certain Electronic Devices, Including Mobile Phones, Portable Music Players, and... electronic devices, including mobile phones, portable music players, and computers by reason of infringement... this investigation may be viewed on the Commission's electronic docket (EDIS) at http://edis.usitc.gov...

  16. 75 FR 34484 - In the Matter of: Certain Portable Electronic Devices and Related Software; Notice of Investigation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-17

    ... COMMISSION In the Matter of: Certain Portable Electronic Devices and Related Software; Notice of... and related software by reason of infringement of certain claims of U.S. Patent Nos. 6,999,800; 5,541... certain portable electronic devices or related software that infringe one or more of claims 1-4, 6, 10,...

  17. 77 FR 1083 - Certain Portable Electronic Devices and Related Software; Determination Not To Review Initial...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-09

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Certain Portable Electronic Devices and Related Software; Determination Not To Review Initial... related software. 76 FR 50253 (Aug. 12, 2011). The complaint alleged the infringement of claims of...

  18. 76 FR 79708 - Certain Portable Electronic Devices And Related Software; Submission for OMB Review; Comment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-22

    ... COMMISSION Certain Portable Electronic Devices And Related Software; Submission for OMB Review; Comment... software by reason of infringement of various claims of United States Patent Nos. 6,999,800 (``the '800... software. Regarding infringement, the ALJ found that Apple does not infringe claims 1-3 and 8-10 of the...

  19. PowerCore{trademark}, NiMH production prototype for portable electronics. Quarterly report R02

    SciTech Connect

    Lyman, P.C.

    1998-01-30

    The objective of this project is to build a production prototype of Power Core structural battery for applications as a hard case for portable electronic devices. The reports summarizes the work completed since the last report. It briefly describes the problems that were experienced. It also gives details of progress versus statement of work task definitions.

  20. A systematic review of portable electronic technology for health education in resource-limited settings.

    PubMed

    McHenry, Megan S; Fischer, Lydia J; Chun, Yeona; Vreeman, Rachel C

    2017-08-01

    The objective of this study is to conduct a systematic review of the literature of how portable electronic technologies with offline functionality are perceived and used to provide health education in resource-limited settings. Three reviewers evaluated articles and performed a bibliography search to identify studies describing health education delivered by portable electronic device with offline functionality in low- or middle-income countries. Data extracted included: study population; study design and type of analysis; type of technology used; method of use; setting of technology use; impact on caregivers, patients, or overall health outcomes; and reported limitations. Searches yielded 5514 unique titles. Out of 75 critically reviewed full-text articles, 10 met inclusion criteria. Study locations included Botswana, Peru, Kenya, Thailand, Nigeria, India, Ghana, and Tanzania. Topics addressed included: development of healthcare worker training modules, clinical decision support tools, patient education tools, perceptions and usability of portable electronic technology, and comparisons of technologies and/or mobile applications. Studies primarily looked at the assessment of developed educational modules on trainee health knowledge, perceptions and usability of technology, and comparisons of technologies. Overall, studies reported positive results for portable electronic device-based health education, frequently reporting increased provider/patient knowledge, improved patient outcomes in both quality of care and management, increased provider comfort level with technology, and an environment characterized by increased levels of technology-based, informal learning situations. Negative assessments included high investment costs, lack of technical support, and fear of device theft. While the research is limited, portable electronic educational resources present promising avenues to increase access to effective health education in resource-limited settings, contingent

  1. Portable pyroelectric electron probe microanalyzer with a spot size of 40 μm

    NASA Astrophysics Data System (ADS)

    Imashuku, Susumu; Wagatsuma, Kazuaki

    2017-02-01

    We report a method of reducing the spot size of an electron beam in a portable pyroelectric electron probe microanalyzer (EPMA) and its application to on-site microanalysis. An electron beam with a spot size of 40 μm full width at half maximum was achieved by preventing the production of an electric field on the side of a needle tip set on the pyroelectric crystal in the EPMA by coating the side of the tip with an insulating material. This spot size was approximately 10 times smaller than that previously reported. We were able to acquire a line scan profile of a thin copper line sputtered on a silicon substrate using the portable pyroelectric EPMA. The width of the sputtered copper evaluated from the line scan profile (120 μm) corresponded to that from a line scan profile obtained by conventional stationary scanning electron microscope-energy dispersive X-ray spectroscopy equipment.

  2. Portable pyroelectric electron probe microanalyzer with a spot size of 40 μm.

    PubMed

    Imashuku, Susumu; Wagatsuma, Kazuaki

    2017-02-01

    We report a method of reducing the spot size of an electron beam in a portable pyroelectric electron probe microanalyzer (EPMA) and its application to on-site microanalysis. An electron beam with a spot size of 40 μm full width at half maximum was achieved by preventing the production of an electric field on the side of a needle tip set on the pyroelectric crystal in the EPMA by coating the side of the tip with an insulating material. This spot size was approximately 10 times smaller than that previously reported. We were able to acquire a line scan profile of a thin copper line sputtered on a silicon substrate using the portable pyroelectric EPMA. The width of the sputtered copper evaluated from the line scan profile (120 μm) corresponded to that from a line scan profile obtained by conventional stationary scanning electron microscope-energy dispersive X-ray spectroscopy equipment.

  3. 77 FR 18860 - Certain Consumer Electronics, Including Mobile Phones and Tablets; Notice of Receipt of Complaint...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-28

    ... COMMISSION Certain Consumer Electronics, Including Mobile Phones and Tablets; Notice of Receipt of Complaint... complaint entitled Certain Consumer Electronics, Including Mobile Phones and Tablets, DN 2885; the... importation of certain consumer electronics, including mobile phones and tablets. The complaint names...

  4. 78 FR 30934 - Certain Consumer Electronics With Display and Processing Capabilities; Notice of Receipt of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-23

    ... COMMISSION Certain Consumer Electronics With Display and Processing Capabilities; Notice of Receipt of... received a complaint entitled Certain Consumer Electronics with Display and Processing Capabilities, DN... within the United States after importation of certain consumer electronics with display and...

  5. Portable retinal imaging for eye disease screening using a consumer-grade digital camera

    NASA Astrophysics Data System (ADS)

    Barriga, Simon; Larichev, Andrey; Zamora, Gilberto; Soliz, Peter

    2012-03-01

    The development of affordable means to image the retina is an important step toward the implementation of eye disease screening programs. In this paper we present the i-RxCam, a low-cost, hand-held, retinal camera for widespread applications such as tele-retinal screening for eye diseases like diabetic retinopathy (DR), glaucoma, and age-related ocular diseases. Existing portable retinal imagers do not meet the requirements of a low-cost camera with sufficient technical capabilities (field of view, image quality, portability, battery power, and ease-of-use) to be distributed widely to low volume clinics, such as the offices of single primary care physicians serving rural communities. The i-RxCam uses a Nikon D3100 digital camera body. The camera has a CMOS sensor with 14.8 million pixels. We use a 50mm focal lens that gives a retinal field of view of 45 degrees. The internal autofocus can compensate for about 2D (diopters) of focusing error. The light source is an LED produced by Philips with a linear emitting area that is transformed using a light pipe to the optimal shape at the eye pupil, an annulus. To eliminate corneal reflex we use a polarization technique in which the light passes through a nano-wire polarizer plate. This is a novel type of polarizer featuring high polarization separation (contrast ratio of more than 1000) and very large acceptance angle (>45 degrees). The i-RxCam approach will yield a significantly more economical retinal imaging device that would allow mass screening of the at-risk population.

  6. National energy use of consumer electronics in 1999

    SciTech Connect

    Rosen, Karen; Meier, Alan; Zandelin, Stefan

    2000-02-15

    The major consumer electronics in U.S. homes accounted for nearly 7 percent of U.S. residential electricity consumption in 1999. We attribute more than half of this figure (3.6 percent) to televisions, videocassette recorders, and DVD players, and nearly one-third (1.8 percent) to audio products. Set-top boxes currently account for a relatively small fraction of residential electricity use (0.7 percent), but we expect this end-use to grow quickly with the proliferation of digital set-top boxes, which currently use 40 percent more energy per unit than the average TV set. In all, these consumer electronics plus telephone products consumed 75 TWh in the U.S. in 1999, half of which was consumed while the products were not in use. This energy use is expected to grow as products with new or advanced functionality hit the market.

  7. Glass fragments from portable electronic devices: Implications for forensic examinations.

    PubMed

    Seyfang, Kelsey E; Redman, Kahlee E; Popelka-Filcoff, Rachel S; Kirkbride, K Paul

    2015-12-01

    Personal electronic devices (PEDs) are now widespread in the community. Many such devices have glass display screens that, despite being a relatively strong and specialised material, are vulnerable to breakage. Unlike other glass objects that are usually thrown away when they break, PEDs can still function with a broken or cracked screen and it is not uncommon for their owners to keep using them in this condition. Broken PED screens, therefore, might represent a new and significant source of glass fragments that are present on the clothing and belongings of the general public and individuals suspected of offences involving the breaking of glass. The forensic implications of this new source of glass fragments in the community were investigated. PED glass is easily recognised using scanning electron microscopy-energy dispersive X-ray analysis and refractive index measurement and is easily distinguished from domestic and automotive soda-lime glass using these methods; as a consequence there should be no confusion of soda-lime glass fragments and PED glass fragments in forensic glass casework. In cases where the objective is to compare recovered glass fragments to a putative PED source, comparison using refractive index measurement and elemental analysis achieves good discrimination between sources. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. The use and risk of portable electronic devices while cycling among different age groups.

    PubMed

    Goldenbeld, C; Houtenbos, M; Ehlers, E; De Waard, D

    2012-02-01

    In the Netherlands, a survey was set up to monitor the extent of the use of portable, electronic devices while cycling amongst different age groups of cyclists and to estimate the possible consequences for safety. The main research questions concerned age differences in the self-reported use of electronic devices while cycling, self-reported crash involvement and risk, and self-reported compensatory behaviour. Teen cyclists (12-17 years) and young adult cyclists (18-34 years) were more frequent users, and also more indiscriminate users of portable devices while cycling than middle-aged and older adult cyclists (35-49 years; 50+ years). After statistical correction for influences on crash risk of urbanization level, weekly time spent cycling, and cycling in more demanding traffic situations, the odds of being involved in a bicycle crash were estimated to be higher for teen cyclists and young adult cyclists who used electronic devices on every trip compared to same age groups cyclists who never used these devices. For middle-aged and older adult cyclists, the use of portable electronic devices was not a significant predictor of bicycle crashes, but frequency of cycling in demanding traffic situations was. Possible implications for education or legal measures are discussed. Results may inform researchers, policy makers, and cyclists themselves. Educational campaigns may use risk information to warn young cyclists about risk of device use while cycling. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Consumers' perceptions of patient-accessible electronic medical records.

    PubMed

    Zarcadoolas, Christina; Vaughon, Wendy L; Czaja, Sara J; Levy, Joslyn; Rockoff, Maxine L

    2013-08-26

    Electronic health information (eHealth) tools for patients, including patient-accessible electronic medical records (patient portals), are proliferating in health care delivery systems nationally. However, there has been very limited study of the perceived utility and functionality of portals, as well as limited assessment of these systems by vulnerable (low education level, racial/ethnic minority) consumers. The objective of the study was to identify vulnerable consumers' response to patient portals, their perceived utility and value, as well as their reactions to specific portal functions. This qualitative study used 4 focus groups with 28 low education level, English-speaking consumers in June and July 2010, in New York City. Participants included 10 males and 18 females, ranging in age from 21-63 years; 19 non-Hispanic black, 7 Hispanic, 1 non-Hispanic White and 1 Other. None of the participants had higher than a high school level education, and 13 had less than a high school education. All participants had experience with computers and 26 used the Internet. Major themes were enhanced consumer engagement/patient empowerment, extending the doctor's visit/enhancing communication with health care providers, literacy and health literacy factors, improved prevention and health maintenance, and privacy and security concerns. Consumers were also asked to comment on a number of key portal features. Consumers were most positive about features that increased convenience, such as making appointments and refilling prescriptions. Consumers raised concerns about a number of potential barriers to usage, such as complex language, complex visual layouts, and poor usability features. Most consumers were enthusiastic about patient portals and perceived that they had great utility and value. Study findings suggest that for patient portals to be effective for all consumers, portals must be designed to be easy to read, visually engaging, and have user-friendly navigation.

  10. Development of a Portable Electronic Nose System for the Detection and Classification of Fruity Odors

    PubMed Central

    Tang, Kea-Tiong; Chiu, Shih-Wen; Pan, Chih-Heng; Hsieh, Hung-Yi; Liang, Yao-Sheng; Liu, Ssu-Chieh

    2010-01-01

    In this study, we have developed a prototype of a portable electronic nose (E-Nose) comprising a sensor array of eight commercially available sensors, a data acquisition interface PCB, and a microprocessor. Verification software was developed to verify system functions. Experimental results indicate that the proposed system prototype is able to identify the fragrance of three fruits, namely lemon, banana, and litchi. PMID:22163403

  11. Use of portable electronic devices in a hospital setting and their potential for bacterial colonization.

    PubMed

    Khan, Amber; Rao, Amitha; Reyes-Sacin, Carlos; Hayakawa, Kayoko; Szpunar, Susan; Riederer, Kathleen; Kaye, Keith; Fishbain, Joel T; Levine, Diane

    2015-03-01

    Portable electronic devices are increasingly being used in the hospital setting. As with other fomites, these devices represent a potential reservoir for the transmission of pathogens. We conducted a convenience sampling of devices in 2 large medical centers to identify bacterial colonization rates and potential risk factors. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  12. Design of a portable electronic nose for real-fake detection of liquors

    NASA Astrophysics Data System (ADS)

    Qi, Pei-Feng; Zeng, Ming; Li, Zhi-Hua; Sun, Biao; Meng, Qing-Hao

    2017-09-01

    Portability is a major issue that influences the practical application of electronic noses (e-noses). For liquors detection, an e-nose must preprocess the liquid samples (e.g., using evaporation and thermal desorption), which makes the portable design even more difficult. To realize convenient and rapid detection of liquors, we designed a portable e-nose platform that consists of hardware and software systems. The hardware system contains an evaporation/sampling module, a reaction module, a control/data acquisition and analysis module, and a power module. The software system provides a user-friendly interface and can achieve automatic sampling and data processing. This e-nose platform has been applied to the real-fake recognition of Chinese liquors. Through parameter optimization of a one-class support vector machine classifier, the error rate of the negative samples is greatly reduced, and the overall recognition accuracy is improved. The results validated the feasibility of the designed portable e-nose platform.

  13. Consumers' Perceptions of Patient-Accessible Electronic Medical Records

    PubMed Central

    Vaughon, Wendy L; Czaja, Sara J; Levy, Joslyn; Rockoff, Maxine L

    2013-01-01

    Background Electronic health information (eHealth) tools for patients, including patient-accessible electronic medical records (patient portals), are proliferating in health care delivery systems nationally. However, there has been very limited study of the perceived utility and functionality of portals, as well as limited assessment of these systems by vulnerable (low education level, racial/ethnic minority) consumers. Objective The objective of the study was to identify vulnerable consumers’ response to patient portals, their perceived utility and value, as well as their reactions to specific portal functions. Methods This qualitative study used 4 focus groups with 28 low education level, English-speaking consumers in June and July 2010, in New York City. Results Participants included 10 males and 18 females, ranging in age from 21-63 years; 19 non-Hispanic black, 7 Hispanic, 1 non-Hispanic White and 1 Other. None of the participants had higher than a high school level education, and 13 had less than a high school education. All participants had experience with computers and 26 used the Internet. Major themes were enhanced consumer engagement/patient empowerment, extending the doctor’s visit/enhancing communication with health care providers, literacy and health literacy factors, improved prevention and health maintenance, and privacy and security concerns. Consumers were also asked to comment on a number of key portal features. Consumers were most positive about features that increased convenience, such as making appointments and refilling prescriptions. Consumers raised concerns about a number of potential barriers to usage, such as complex language, complex visual layouts, and poor usability features. Conclusions Most consumers were enthusiastic about patient portals and perceived that they had great utility and value. Study findings suggest that for patient portals to be effective for all consumers, portals must be designed to be easy to read, visually

  14. 47 CFR 76.630 - Compatibility with consumer electronics equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... equipment. 76.630 Section 76.630 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST... Compatibility with consumer electronics equipment. (a) Cable system operators shall not scramble or otherwise... cable system terminal devices and other customer premises equipment that incorporates remote control...

  15. Questioning Behavior on a Consumer Health Electronic List.

    ERIC Educational Resources Information Center

    White, Marilyn Domas

    2000-01-01

    Using a thorough analytical framework, this study characterizes the questioning behavior on a consumer health-related electronic list. Analysis examines the dedication of the list to questioning; pattern of question asking within a message; type of question; length of answer anticipated; subject of question; combination of type of question and…

  16. Consumer Electronic Product Servicing. Florida Vocational Program Guide.

    ERIC Educational Resources Information Center

    University of South Florida, Tampa. Dept. of Adult and Vocational Education.

    This program guide identifies primary concerns in the organization, operation, and evaluation of a consumer electronic product servicing program. It is designed for local school district and community college administrators, instructors, program advisory committees, and regional coordinating councils. The guide begins with the Dictionary of…

  17. Consumer Electronic Product Servicing. Florida Vocational Program Guide.

    ERIC Educational Resources Information Center

    University of South Florida, Tampa. Dept. of Adult and Vocational Education.

    This packet contains a program guide and Career Merit Achievement Plan (Career MAP) for the implementation of a consumer electronic product servicing program in Florida secondary and postsecondary schools. The program guide describes the program content and structure, provides a program description, lists job titles under the program, and includes…

  18. Architecture of portable electronic medical records system integrated with streaming media.

    PubMed

    Chen, Wei; Shih, Chien-Chou

    2012-02-01

    Due to increasing occurrence of accidents and illness during business trips, travel, or overseas studies, the requirement for portable EMR (Electronic Medical Records) has increased. This study proposes integrating streaming media technology into the EMR system to facilitate referrals, contracted laboratories, and disease notification among hospitals. The current study encoded static and dynamic medical images of patients into a streaming video format and stored them in a Flash Media Server (FMS). Based on the Taiwan Electronic Medical Record Template (TMT) standard, EMR records can be converted into XML documents and used to integrate description fields with embedded streaming videos. This investigation implemented a web-based portable EMR interchanging system using streaming media techniques to expedite exchanging medical image information among hospitals. The proposed architecture of the portable EMR retrieval system not only provides local hospital users the ability to acquire EMR text files from a previous hospital, but also helps access static and dynamic medical images as reference for clinical diagnosis and treatment. The proposed method protects property rights of medical images through information security mechanisms of the Medical Record Interchange Service Center and Health Certificate Authorization to facilitate proper, efficient, and continuous treatment of patients.

  19. Lithium-ion Battery Charge Methodologies Observed with Portable Electronic Equipment

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith

    2009-01-01

    Commercial lithium-ion batteries in portable electronic equipment has been used by NASA for space applications since 1999. First battery that was certified for flight and flown for Shuttle use was the Canon BP 927 (2.7 Ah) battery pack. Since then, numerous portable equipment with li-ion batteries have been certified and flown and remain on-orbit for crew usage. Laptops (two generations with third one being worked on now) Camcorder Camera PDA 2 versions (second one being li-ion polymer cells) Satellite Phone Due to expense and time, certified batteries are used with different equipment with the help of adapters or by working with the manufacturer of the equipment to build the appropriate battery compartment and connector. Certified and dedicated chargers are available on Shuttle and on the ISS for safe charging.

  20. Concurrent determination of anions and cations in consumer fireworks with a portable dual-capillary electrophoresis system.

    PubMed

    Sáiz, Jorge; Duc, Mai Thanh; Koenka, Israel Joel; Martín-Alberca, Carlos; Hauser, Peter C; García-Ruiz, Carmen

    2014-11-01

    A new automated portable dual-channel capillary electrophoresis instrument was built and applied to the concurrent determination of cations and anions. The system uses a single buffer and hydrodynamic injection of the sample is performed autonomously. A novel engraved flow-cell interface is used at the injection ends of the capillaries allowing the autonomous operation of the system. The engraved flow-cell replaces traditionally used split injectors in purpose made capillary electrophoresis systems and makes the system design easier. A new software package with graphical user interface was employed to control the system, making its operation simple and increasing its versatility. The electrophoretic method was optimized to allow the baseline separation of 12 cations and anions commonly found in fireworks. The system was proven to be useful for the analysis of consumer fireworks, saving time and expenses compared to separate analyses for anions and cations. This is the first time that cationic and anionic compositions of fireworks are investigated together. The analysis of samples revealed several inaccuracies between the declared compositions for the fireworks and the obtained results, which could be attributed to cross-contamination during their manufacture or to a transfer between other components of the pyrotechnic item. The presence of certain unexpected peaks, however, had no apparent reason and might represent an irregularity in the manufacture of some devices.

  1. 78 FR 56245 - Certain Wireless Consumer Electronics Devices and Components Thereof; Notice of Request for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-12

    ... COMMISSION Certain Wireless Consumer Electronics Devices and Components Thereof; Notice of Request for... limited exclusion order against certain wireless consumer electronics devices and components thereof... Corporation of Kyoto, Japan; Kyocera Communications, Inc. of San Diego, California; LG Electronics, Inc....

  2. Redesigning a collection system for "small" consumer electronics.

    PubMed

    Melissen, Frans W

    2006-01-01

    This paper establishes that the collection system within the recycling scheme for consumer electronics in the Netherlands has not been entirely successful in convincing consumers to hand in their used appliances by means of dedicated collection routes. Particularly regarding small appliances, consumers are persisting in their habit of discarding their appliances by means of the refuse bag/bin for regular household waste. Therefore, the current collection system has been unable to direct consumer behavior in the desired direction. Consequently, the layout of the current system is reviewed and redesigned in order to tackle this problem. This design effort applies the Triad model (behavioral model) in the analysis stage and the Morphological Chart method (design tool) in the synthesis stage, and results in a concrete proposal for a new system. Finally, the applicability of this design approach beyond the specific circumstances of the case study presented in this paper is discussed. This case represents only one example of the broader, worldwide challenge to design appropriate collection systems to direct consumer behavior in desired directions. It is argued that the approach presented in this paper could be a valuable contribution to research dealing with this challenge.

  3. Redesigning a collection system for 'small' consumer electronics

    SciTech Connect

    Melissen, Frans W. . E-mail: f.w.melissen@rug.nl

    2006-07-01

    This paper establishes that the collection system within the recycling scheme for consumer electronics in the Netherlands has not been entirely successful in convincing consumers to hand in their used appliances by means of dedicated collection routes. Particularly regarding small appliances, consumers are persisting in their habit of discarding their appliances by means of the refuse bag/bin for regular household waste. Therefore, the current collection system has been unable to direct consumer behavior in the desired direction. Consequently, the layout of the current system is reviewed and redesigned in order to tackle this problem. This design effort applies the Triad model (behavioral model) in the analysis stage and the Morphological Chart method (design tool) in the synthesis stage, and results in a concrete proposal for a new system. Finally, the applicability of this design approach beyond the specific circumstances of the case study presented in this paper is discussed. This case represents only one example of the broader, worldwide challenge to design appropriate collection systems to direct consumer behavior in desired directions. It is argued that the approach presented in this paper could be a valuable contribution to research dealing with this challenge.

  4. Improving Short Term Instability for Quantitative Analyses with Portable Electronic Noses

    PubMed Central

    Macías, Miguel Macías; Agudo, J. Enrique; Manso, Antonio García; Orellana, Carlos Javier García; Velasco, Horacio Manuel González; Caballero, Ramón Gallardo

    2014-01-01

    One of the main problems when working with electronic noses is the lack of reproducibility or repeatability of the sensor response, so that, if this problem is not properly considered, electronic noses can be useless, especially for quantitative analyses. On the other hand, irreproducibility is increased with portable and low cost electronic noses where laboratory equipment like gas zero generators cannot be used. In this work, we study the reproducibility of two portable electronic noses, the PEN3 (commercial) and CAPINose (a proprietary design) by using synthetic wine samples. We show that in both cases short term instability associated to the sensors' response to the same sample and under the same conditions represents a major problem and we propose an internal normalization technique that, in both cases, reduces the variability of the sensors' response. Finally, we show that the normalization proposed seems to be more effective in the CAPINose case, reducing, for example, the variability associated to the TGS2602 sensor from 12.19% to 2.2%. PMID:24932869

  5. Evaluation of low energy electron beam dose application by means of a portable optical device

    NASA Astrophysics Data System (ADS)

    Reitzig, Manuela; Winkler, Martin; Härtling, Thomas; Röder, Olaf; Opitz, Jörg

    2014-11-01

    We present our recent development concerning the evaluation of a low energy dose application to electron beam responding materials with a simple portable optical device. Electron beam irradiation is a promising option to sterilize sensitive and high performance products or surfaces at a low temperature and without moisture. Especially in the fields of the food industry and medicine, regulations regarding sterility are increasingly tightened. Because of this, a secure proof for electron-beam-assisted sterilization is required. However, no nondestructive and in situ method exists up until now. Our approach to provide a secure proof of sterilization is to place a suitable marker material based on rare-earth-doped phosphors inside or on the top of the packaging material of the respective product. Upon electron irradiation the marker material changes its luminescence properties as a function of the applied energy dose. We verified the energy dependence by means of time-resolved measurements of the luminescence decay of an upconversion phosphor with a portable optical device. In our experimental realization, short laser pulses in the near-infrared range are triggered by a microcontrol unit (MCU) and excite the marker material. The light emitted by the marker is collected in the range between 400 and 1100 nm via a silicon photodiode, processed by the MCU, and analyzed in a Labview program via a single-exponential fit. As a main result, we observe an increasing reduction of the luminescence lifetime with higher dose applications.

  6. A Portable Electronic Nose For Toxic Vapor Detection, Identification, and Quantification

    NASA Technical Reports Server (NTRS)

    Linnell, B. R.; Young, R. C.; Griffin, T. P.; Meneghelli, B. J.; Peterson, B. V.; Brooks, K. B.

    2005-01-01

    A new prototype instrument based on electronic nose (e-nose) technology has demonstrated the ability to identify and quantify many vapors of interest to the Space Program at their minimum required concentrations for both single vapors and two-component vapor mixtures, and may easily be adapted to detect many other toxic vapors. To do this, it was necessary to develop algorithms to classify unknown vapors, recognize when a vapor is not any of the vapors of interest, and estimate the concentrations of the contaminants. This paper describes the design of the portable e-nose instrument, test equipment setup, test protocols, pattern recognition algorithms, concentration estimation methods, and laboratory test results.

  7. Possible application of carbon nanotubes to the field emission electron source for portable betatrons

    NASA Astrophysics Data System (ADS)

    Ohnishi, Takehiro; Endo, Ichita; Hayashi, Kenji; Kohara, Akitsugu; Yoshida, Takuo; Lukyanovich Chakhlov, Gennady; Leonidovich Malikov, Evgeny; Petrovich Naydukov, Aleksey; Ekino, Toshikazu; Nishiyama, Fumitaka

    2005-02-01

    In order to study the feasibility of a carbon nanotube-based electron gun for small and portable betatrons, the characteristics of electron emission from carbon nanotubes were measured at around ≈1×10 -4 Pa, a typical pressure in the vacuum chamber of such betatrons. The sample cathodes were made from powders of single-walled nanotube (SWNT) and multi-walled nanotube (MWNT) that were fixed on the stainless steel plate with gold paste. We found that the emission was weaker at the lower vacuum for both MWNT and SWNT. However, when the vacuum level was restored to ≈1×10 -4 Pa after being kept at 4.0×10 -4 Pa for 15 minutes, the emission-current recovered to some extent but did not fully come back to the original value. The observed current densities from SWNT and MWNT are 550 and 540 μA/mm 2, respectively, at the high-voltage we tried: 2 kV for SWNT and 1.1 kV for MWNT across a 300 μm gap. It is likely that the carbon nanotube, under the pulsed operation, has advantages over the thermal cathode for the electron emitters of portable betatrons.

  8. 77 FR 51572 - Certain Wireless Consumer Electronics Devices and Components Thereof; Institution of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-24

    ... COMMISSION Certain Wireless Consumer Electronics Devices and Components Thereof; Institution of Investigation... Properties Limited LLC of Cupertino, California, Phoenix Digital Solutions LLC of Cupertino, California, and... United States after importation of certain wireless consumer electronics devices and components...

  9. 77 FR 44671 - Certain Wireless Consumer Electronics Devices and Components Thereof; Notice of Receipt of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-30

    ... COMMISSION Certain Wireless Consumer Electronics Devices and Components Thereof; Notice of Receipt of... received a complaint entitled Certain Wireless Consumer Electronics Devices and Components Thereof, DN 2904... of Technology Properties Limited LLC, Phoenix Digital Solutions LLC and Patriot...

  10. 76 FR 66666 - Basic Service Tier Encryption Compatibility Between Cable Systems and Consumer Electronics Equipment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-27

    ... Electronics Equipment AGENCY: Federal Communications Commission. ACTION: Proposed rule. SUMMARY: In this... consumer electronics equipment for most subscribers. At the same time, however, we recognize that some... Act), Congress recognized that compatibility problems between cable service and consumer...

  11. Frugal Droplet Microfluidics Using Consumer Opto-Electronics.

    PubMed

    Frot, Caroline; Taccoen, Nicolas; Baroud, Charles N

    2016-01-01

    The maker movement has shown how off-the-shelf devices can be combined to perform operations that, until recently, required expensive specialized equipment. Applying this philosophy to microfluidic devices can play a fundamental role in disseminating these technologies outside specialist labs and into industrial use. Here we show how nanoliter droplets can be manipulated using a commercial DVD writer, interfaced with an Arduino electronic controller. We couple the optical setup with a droplet generation and manipulation device based on the "confinement gradients" approach. This device uses regions of different depths to generate and transport the droplets, which further simplifies the operation and reduces the need for precise flow control. The use of robust consumer electronics, combined with open source hardware, leads to a great reduction in the price of the device, as well as its footprint, without reducing its performance compared with the laboratory setup.

  12. Frugal Droplet Microfluidics Using Consumer Opto-Electronics

    PubMed Central

    Frot, Caroline; Taccoen, Nicolas; Baroud, Charles N.

    2016-01-01

    The maker movement has shown how off-the-shelf devices can be combined to perform operations that, until recently, required expensive specialized equipment. Applying this philosophy to microfluidic devices can play a fundamental role in disseminating these technologies outside specialist labs and into industrial use. Here we show how nanoliter droplets can be manipulated using a commercial DVD writer, interfaced with an Arduino electronic controller. We couple the optical setup with a droplet generation and manipulation device based on the “confinement gradients” approach. This device uses regions of different depths to generate and transport the droplets, which further simplifies the operation and reduces the need for precise flow control. The use of robust consumer electronics, combined with open source hardware, leads to a great reduction in the price of the device, as well as its footprint, without reducing its performance compared with the laboratory setup. PMID:27560139

  13. 76 FR 72439 - Certain Consumer Electronics and Display Devices and Products Containing Same; Receipt of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-23

    ...-72440] [FR Doc No: 2011-30184] INTERNATIONAL TRADE COMMISSION [DN 2858] Certain Consumer Electronics and... Consumer Electronics and Display Devices and Products Containing Same, DN 2858; the Commission is... importation of certain consumer electronics and display devices and products containing same. The...

  14. 77 FR 24514 - Certain Consumer Electronics, Including Mobile Phones and Tablets; Institution of Investigation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-24

    ... COMMISSION Certain Consumer Electronics, Including Mobile Phones and Tablets; Institution of Investigation... consumer electronics, including mobile phones and tablets, by reason of infringement of certain claims of U... importation, or the sale within the United States after importation of certain consumer electronics,...

  15. 77 FR 14422 - Certain Consumer Electronics and Display Devices and Products Containing Same; Notice of Receipt...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-09

    ... COMMISSION Certain Consumer Electronics and Display Devices and Products Containing Same; Notice of Receipt... Commission has received a complaint entitled Certain Consumer Electronics and Display Devices and Products... importation, and the sale within the United States after importation of certain consumer electronics...

  16. A Portable Electronic Nose for Toxic Vapor Detection, Identification, and Quantification

    NASA Technical Reports Server (NTRS)

    Linnell, B. R.; Young, R. C.; Griffin, T. P.; Meneghelli, B. J.; Peterson, B. V.; Brooks, K. B.

    2005-01-01

    The Space Program and military use large quantities of hydrazine and monomethyl hydrazine as rocket propellant, which are very toxic and suspected human carcinogens. Current off-the-shelf portable instruments require 10 to 20 minutes of exposure to detect these compounds at the minimum required concentrations and are prone to false positives, making them unacceptable for many operations. In addition, post-mission analyses of grab bag air samples from the Shuttle have confirmed the occasional presence of on-board volatile organic contaminants, which also need to be monitored to ensure crew safety. A new prototype instrument based on electronic nose (e-nose) technology has demonstrated the ability to qualify (identify) and quantify many of these vapors at their minimum required concentrations, and may easily be adapted to detect many other toxic vapors. To do this, it was necessary to develop algorithms to classify unknown vapors, recognize when a vapor is not any of the vapors of interest, and estimate the concentrations of the contaminants. This paper describes the design of the portable e-nose instrument, test equipment setup, test protocols, pattern recognition algorithms, concentration estimation methods, and laboratory test results.

  17. Method to fabricate portable electron source based on nitrogen incorporated ultrananocrystalline diamond (N-UNCD)

    DOEpatents

    Sumant, Anirudha V.; Divan, Ralu; Posada, Chrystian M.; Castano, Carlos H.; Grant, Edwin J.; Lee, Hyoung K.

    2016-03-29

    A source cold cathode field emission array (FEA) source based on ultra-nanocrystalline diamond (UNCD) field emitters. This system was constructed as an alternative for detection of obscured objects and material. Depending on the geometry of the given situation a flat-panel source can be used in tomography, radiography, or tomosynthesis. Furthermore, the unit can be used as a portable electron or X-ray scanner or an integral part of an existing detection system. UNCD field emitters show great field emission output and can be deposited over large areas as the case with carbon nanotube "forest" (CNT) cathodes. Furthermore, UNCDs have better mechanical and thermal properties as compared to CNT tips which further extend the lifetime of UNCD based FEA.

  18. Embedding a hiding function in a portable electronic health record for privacy preservation.

    PubMed

    Huang, Lu-Chou; Chu, Huei-Chung; Lien, Chung-Yueh; Hsiao, Chia-Hung; Kao, Tsair

    2010-06-01

    The objective of this study was to develop a method to hide information in a portable electronic health record (PEHR). In compliance with HIPAA guidelines, a hiding function for personal identifiers in a PEHR was implemented by recognizing and hiding techniques. The method emphasizes the feasibility of embedding a hiding function in a PEHR. The hiding function could be executed to hide identifiers in offline mode. The present study showed that embedding the hiding function in a PEHR is a practical way not only satisfies data confidentiability needs, but also meets patient's personal privacy requirements. The effects of executing the hiding function would be the same as through de-identification or anonymization process.

  19. Direct Methanol Fuel Cell Prototype Demonstration for Consumer Electronics Applications

    SciTech Connect

    Carlstrom, Charles, M., Jr.

    2009-07-07

    This report is the final technical report for DOE Program DE-FC36-04GO14301 titled “Direct Methanol Fuel Cell Prototype Demonstration for Consumer Electronics Applications”. Due to the public nature of this report some of the content reported in confidential reports and meetings to the DOE is not covered in detail in this report and some of the content has been normalized to not show actual values. There is a comparison of the projects accomplishments with the objectives, an overview of some of the key subsystem work, and a review of the three levels of prototypes demonstrated during the program. There is also a description of the eventual commercial product and market this work is leading towards. The work completed under this program has significantly increased the understanding of how Direct Methanol Fuel Cells (DMFC) can be deployed successfully to power consumer electronic devices. The prototype testing has demonstrated the benefits a direct methanol fuel cell system has over batteries typically used for powering consumer electronic devices. Three generations of prototypes have been developed and tested for performance, robustness and life. The technologies researched and utilized in the fuel cell stack and related subsystems for these prototypes are leveraged from advances in other industries such as the hydrogen fueled PEM fuel cell industry. The work under this program advanced the state of the art of direct methanol fuel cells. The system developed by MTI micro fuel cells aided by this program differs significantly from conventional DMFC designs and offers compelling advantages in the areas of performance, life, size, and simplicity. The program has progressed as planned resulting in the completion of the scope of work and available funding in December 2008. All 18 of the final P3 prototypes builds have been tested and the results showed significant improvements over P2 prototypes in build yield, initial performance, and durability. The systems have

  20. 78 FR 13895 - Certain Consumer Electronics, Including Mobile Phones and Tablets; Commission Determination Not...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-01

    ... COMMISSION Certain Consumer Electronics, Including Mobile Phones and Tablets; Commission Determination Not To... importation, or sale within the United States after importation of certain consumer electronics, including...''); LG Electronics, Inc. of Seoul, Republic of Korea, LG Electronics U.S.A., Inc. of Englewood...

  1. Portable Electronic Tongue Based on Microsensors for the Analysis of Cava Wines

    PubMed Central

    Giménez-Gómez, Pablo; Escudé-Pujol, Roger; Capdevila, Fina; Puig-Pujol, Anna; Jiménez-Jorquera, Cecilia; Gutiérrez-Capitán, Manuel

    2016-01-01

    Cava is a quality sparkling wine produced in Spain. As a product with a designation of origin, Cava wine has to meet certain quality requirements throughout its production process; therefore, the analysis of several parameters is of great interest. In this work, a portable electronic tongue for the analysis of Cava wine is described. The system is comprised of compact and low-power-consumption electronic equipment and an array of microsensors formed by six ion-selective field effect transistors sensitive to pH, Na+, K+, Ca2+, Cl−, and CO32−, one conductivity sensor, one redox potential sensor, and two amperometric gold microelectrodes. This system, combined with chemometric tools, has been applied to the analysis of 78 Cava wine samples. Results demonstrate that the electronic tongue is able to classify the samples according to the aging time, with a percentage of correct prediction between 80% and 96%, by using linear discriminant analysis, as well as to quantify the total acidity, pH, volumetric alcoholic degree, potassium, conductivity, glycerol, and methanol parameters, with mean relative errors between 2.3% and 6.0%, by using partial least squares regressions. PMID:27801796

  2. Nanoscale triboelectric-effect-enabled energy conversion for sustainably powering portable electronics.

    PubMed

    Wang, Sihong; Lin, Long; Wang, Zhong Lin

    2012-12-12

    Harvesting energy from our living environment is an effective approach for sustainable, maintenance-free, and green power source for wireless, portable, or implanted electronics. Mechanical energy scavenging based on triboelectric effect has been proven to be simple, cost-effective, and robust. However, its output is still insufficient for sustainably driving electronic devices/systems. Here, we demonstrated a rationally designed arch-shaped triboelectric nanogenerator (TENG) by utilizing the contact electrification between a polymer thin film and a metal thin foil. The working mechanism of the TENG was studied by finite element simulation. The output voltage, current density, and energy volume density reached 230 V, 15.5 μA/cm(2), and 128 mW/cm(3), respectively, and an energy conversion efficiency as high as 10-39% has been demonstrated. The TENG was systematically studied and demonstrated as a sustainable power source that can not only drive instantaneous operation of light-emitting diodes (LEDs) but also charge a lithium ion battery as a regulated power module for powering a wireless sensor system and a commercial cell phone, which is the first demonstration of the nanogenerator for driving personal mobile electronics, opening the chapter of impacting general people's life by nanogenerators.

  3. 46 CFR 67.218 - Optional filing of instruments in portable document format as attachments to electronic mail.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... recording under § 67.200 may be submitted in portable document format (.pdf) as an attachment to electronic... submitted for filing in .pdf format pertains to a vessel that is not a currently documented vessel, a... with the National Vessel Documentation Center or must be submitted in .pdf format with the instrument...

  4. Review of Twenty-First Century Portable Electronic Devices for Persons with Moderate Intellectual Disabilities and Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Mechling, Linda C.

    2011-01-01

    Use of portable electronic devices by persons with moderate intellectual disabilities and autism spectrum disorders is gaining increased research attention. The purpose of this review was to synthesize twenty-first century literature (2000-2010) focusing on these technologies. Twenty-one studies were identified which evaluated use of: (a) handheld…

  5. Generation and Characterization of Nanoaerosols Using a Portable Scanning Mobility Particle Sizer and Electron Microscopy

    NASA Astrophysics Data System (ADS)

    Marty, Adam J.

    The purpose of this research is to demonstrate the ability to generate and characterize a nanometer sized aerosol using solutions, suspensions, and a bulk nanopowder, and to research the viability of using an acoustic dry aerosol generator/elutriator (ADAGE) to aerosolize a bulk nanopowder into a nanometer sized aerosol. The research compares the results from a portable scanning mobility particle sizer (SMPS) to the more traditional method of counting and sizing particles on a filter sample using scanning electron microscopy (SEM). Sodium chloride aerosol was used for the comparisons. The sputter coating thickness, a conductive coating necessary for SEM, was measured on different sizes of polystyrene latex spheres (PSLS). Aluminum oxide powder was aerosolized using an ADAGE and several different support membranes and sound frequency combinations were explored. A portable SMPS was used to determine the size distributions of the generated aerosols. Polycarbonate membrane (PCM) filter samples were collected for subsequent SEM analysis. The particle size distributions were determined from photographs of the membrane filters. SMPS data and membrane samples were collected simultaneously. The sputter coating thicknesses on four different sizes of PSLS, range 57 nanometers (nm) to 220 nm, were measured using transmission electron microscopy and the results from the SEM and SMPS were compared after accounting for the sputter coating thickness. Aluminum oxide nanopowder (20 nm) was aerosolized using a modified ADAGE technique. Four different support membranes and four different sound frequencies were tested with the ADAGE. The aerosol was collected onto PCM filters and the samples were examined using SEM. The results indicate that the SMPS and SEM distributions were log-normally distributed with a median diameter of approximately 42 nm and 55 nm, respectively, and geometric standard deviations (GSD) of approximately 1.6 and 1.7, respectively. The two methods yielded similar

  6. 78 FR 14835 - Investigations: Terminations, Modifications and Rulings: Certain Consumer Electronics and Display...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-07

    ... COMMISSION Investigations: Terminations, Modifications and Rulings: Certain Consumer Electronics and Display... electronics devices and display devices and products containing same, by reason of infringement of various... America, Inc. of Bellevue, Washington; LG Electronics, Inc. of Seoul, South Korea; LG...

  7. Electronic Health Records and Information Portability: A Pilot Study in a Rural Primary Healthcare Center in India

    PubMed Central

    Radhakrishna, Kedar; Goud, B. Ramakrishna; Kasthuri, Arvind; Waghmare, Abijeet; Raj, Tony

    2014-01-01

    Clinical documentation and health information portability pose unique challenges in urban and rural areas of India. This article presents findings of a pilot study conducted in a primary health center in rural India. In this article, we focus on primary care in rural India and how a portable health record system could facilitate the availability of medical information at the point of care. We followed a geriatric cohort and a maternal cohort of 308 participants over a nine-month period. Physician encounters were entered into a web-based electronic health record. This information was made available to all study participants through a short messaging service (SMS). Additionally, 135 randomly selected participants from the cohort were issued a USB-based memory card that contained their detailed health records and could be viewed on most computers. The dual portability model implemented in the pilot study demonstrates the utility of the concept. PMID:25214819

  8. Electronic health records and information portability: a pilot study in a rural primary healthcare center in India.

    PubMed

    Radhakrishna, Kedar; Goud, B Ramakrishna; Kasthuri, Arvind; Waghmare, Abijeet; Raj, Tony

    2014-01-01

    Clinical documentation and health information portability pose unique challenges in urban and rural areas of India. This article presents findings of a pilot study conducted in a primary health center in rural India. In this article, we focus on primary care in rural India and how a portable health record system could facilitate the availability of medical information at the point of care. We followed a geriatric cohort and a maternal cohort of 308 participants over a nine-month period. Physician encounters were entered into a web-based electronic health record. This information was made available to all study participants through a short messaging service (SMS). Additionally, 135 randomly selected participants from the cohort were issued a USB-based memory card that contained their detailed health records and could be viewed on most computers. The dual portability model implemented in the pilot study demonstrates the utility of the concept.

  9. The Software Element of the NASA Portable Electronic Device Radiated Emissions Investigation

    NASA Technical Reports Server (NTRS)

    Koppen, Sandra V.; Williams, Reuben A. (Technical Monitor)

    2002-01-01

    NASA Langley Research Center's (LaRC) High Intensity Radiated Fields Laboratory (HIRF Lab) recently conducted a series of electromagnetic radiated emissions tests under a cooperative agreement with Delta Airlines and an interagency agreement with the FAA. The frequency spectrum environment at a commercial airport was measured on location. The environment survey provides a comprehensive picture of the complex nature of the electromagnetic environment present in those areas outside the aircraft. In addition, radiated emissions tests were conducted on portable electronic devices (PEDs) that may be brought onboard aircraft. These tests were performed in both semi-anechoic and reverberation chambers located in the HIRF Lab. The PEDs included cell phones, laptop computers, electronic toys, and family radio systems. The data generated during the tests are intended to support the research on the effect of radiated emissions from wireless devices on aircraft systems. Both tests systems relied on customized control and data reduction software to provide test and instrument control, data acquisition, a user interface, real time data reduction, and data analysis. The software executed on PC's running MS Windows 98 and 2000, and used Agilent Pro Visual Engineering Environment (VEE) development software, Common Object Model (COM) technology, and MS Excel.

  10. A Portable Surface Contamination Monitor Based on the Principle of Optically Stimulated Electron Emission (OSEE)

    NASA Technical Reports Server (NTRS)

    Perey, D. F.

    1996-01-01

    Many industrial and aerospace processes involving the joining of materials, require sufficient surface cleanliness to insure proper bonding. Processes as diverse as painting, welding, or the soldering of electronic circuits will be compromised if prior inspection and removal of surface contaminants is inadequate. As process requirements become more stringent and the number of different materials and identified contaminants increases, various instruments and techniques have been developed for improved inspection. One such technique, based on the principle of Optically Stimulated Electron Emission (OSEE), has been explored for a number of years as a tool for surface contamination monitoring. Some of the benefits of OSEE are: it is non-contacting; requires little operator training; and has very high contamination sensitivity. This paper describes the development of a portable OSEE based surface contamination monitor. The instrument is suitable for both hand-held and robotic inspections with either manual or automated control of instrument operation. In addition, instrument output data is visually displayed to the operator and may be sent to an external computer for archiving or analysis.

  11. Fraction of electrons consumed in electron acceptor reduction and hydrogen thresholds as indicators of halorespiratory physiology

    SciTech Connect

    Loeffler, F.E.; Tiedje, J.M.; Sanford, R.A.

    1999-09-01

    Measurements of the hydrogen consumption threshold and the tracking of electrons transferred to the chlorinated electron acceptor (f{sub e}) reliably detected chlororespiratory physiology in both mixed cultures and pure cultures capable of using tetrachloroethene, cis-1,2-dichloroethene, vinyl chloride, 2-chlorophenol, 3-chlorobenzoate, 3-chloro-4-hydroxybenzoate, or 1,2-dichloropropane as an electron acceptor. Hydrogen was consumed to significantly lower threshold concentrations of less than 0.4 ppmv compared with the values obtained for the same cultures without a chlorinated compound as an electron acceptor. The f{sub e} values ranged from 0.63 to 0.7, values which are in good agreement with theoretical calculations based on the thermodynamics of reductive dechlorination as the terminal electron-accepting process. In contrast, a mixed methanogenic culture that cometabolized 3-chlorophenol exhibited a significantly lower f{sub e} value, 0.012.

  12. 77 FR 21584 - Certain Consumer Electronics and Display Devices and Products Containing Same; Institution of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-10

    ... COMMISSION Certain Consumer Electronics and Display Devices and Products Containing Same; Institution of... States after importation of certain consumer electronics and display devices and products containing same... electronics and display devices and products containing same that infringe one or more of claims 2, 3, 5,...

  13. 76 FR 45860 - In the Matter of Certain Electronic Devices, Including Wireless Communication Devices, Portable...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-01

    ... communication devices, portable music and data processing devices, and tablet computers by reason of... communication devices, portable music and data processing devices, and tablet computers that infringe one or... Music and Data Processing Devices, and Tablet Computers; Notice of Institution of Investigation...

  14. A portable 10-MeV electron linear accelerator as a neutron camera

    SciTech Connect

    Morgado, R.E.

    1989-05-01

    We present the results of a literature search into the present state-of-the-art techniques in producing, moderating, collimating, and imaging thermal neutrons, with an emphasis on radiographic diagnosis. The portable linear accelerator source we describe compares favorably with commercially available laboratory facilities for neutron production, while surpassing existing sources in portability. 16 refs., 10 figs., 4 tabs.

  15. An electronic consumer health library: NetWellness.

    PubMed Central

    Guard, R; Haag, D; Kaya, B; Marine, S; Morris, T; Schick, L; Shoemaker, S

    1996-01-01

    NetWellness is a community-based, consumer-defined grant program supporting the delivery of electronic health information to rural residents of southern Ohio and urban and suburban communities in the Greater Cincinnati tri-state region. NetWellness is a collaboratively developed and publicly and privately funded demonstration project. Information is delivered via ISDN, standard dial, dedicated network connections, and the Internet. TriState Online (Greater Cincinnati's Free-Net) and other southern Ohio Free-Nets are key access points in the larger project communities. The other access points are more than forty workstations distributed at public sites throughout the project's primary geographical area. Design strengths and limitations, training initiatives, technical issues, and the project's impact on medical librarianship are examined in this paper. Also discussed are ways of determining community needs and interest, building political alliances, finding and developing funding sources, and overcoming technical obstacles. NetWellness's Internet address is: http:@www.netwellness.org. PMID:8913548

  16. Determination of Receiver Susceptibility to Radio Frequency Interference from Portable Electronic Devices

    NASA Technical Reports Server (NTRS)

    Nguyen, Truong X.; Ely, Jay J.

    2002-01-01

    With the increasing pressures to allow wireless devices on aircraft, the susceptibility of aircraft receivers to interference from Portable Electronic Devices (PEDs) becomes an increasing concern. Many investigations were conducted in the past, with limited success, to quantify device emissions, path loss, and receiver interference susceptibility thresholds. This paper outlines the recent effort in determining the receiver susceptibility thresholds for ILS, VOR and GPS systems. The effort primarily consists of analysis of data available openly as reported in many RTCA and ICAO documents as well as manufacturers data on receiver sensitivity. Shortcomings with the susceptibility threshold data reported in the RTCA documents are presented, and an approach for an in-depth study is suggested. In addition, intermodulation products were observed and demonstrated in a laboratory experiment when multiple PEDs were in the proximity of each other. These intermodulation effects generate spurious frequencies that may fall within aircraft communication or navigation bands causing undesirable effects. Results from a preliminary analysis are presented that show possible harmful combinations of PEDs and the potentially affected aircraft bands.

  17. Power sources for portable electronics and hybrid cars: lithium batteries and fuel cells.

    PubMed

    Scrosati, Bruno

    2005-01-01

    The activities in progress in our laboratory for the development of batteries and fuel cells for portable electronics and hybrid car applications are reviewed and discussed. In the case of lithium batteries, the research has been mainly focused on the characterization of new electrode and electrolyte materials. Results related to disordered carbon anodes and improved, solvent-free, as well as gel-type, polymer electrolytes are particularly stressed. It is shown that the use of proper gel electrolytes, in combination with suitable electrode couples, allows the development of new types of safe, reliable, and low-cost lithium ion batteries which appear to be very promising power sources for hybrid vehicles. Some of the technologies proven to be successful in the lithium battery area are readapted for use in fuel cells. In particular, this approach has been followed for the preparation of low-cost and stable protonic membranes to be proposed as an alternative to the expensive, perfluorosulfonic membranes presently used in polymer electrolyte membrane fuel cells (PEMFCs). Copyright 2005 The Japan Chemical Journal Forum and Wiley Periodicals, Inc

  18. MyCare Card Development: portable GUI framework for the personal electronic health record device.

    PubMed

    Rybynok, V O; Kyriacou, P A; Binnersley, J; Woodcock, A

    2011-01-01

    In most emergency situations, health professionals rely on patients to provide information about their medical history. However, in some cases patients might not be able to communicate this information, and in most countries an online integrated patient record system has not been adopted yet. Therefore, in order to address this issue the ongoing project MyCare Card (MyC², www.myc2.org) has been established. The aim of this project is to design, implement, and evaluate a prototype patient held electronic health record device. Due to the wide range of user requirements, the device, its communication interface, and its software have to be compatible with many common platforms and operating systems. Thus, this paper is addressing one of the software compatibility matters-the cross-platform GUI implementation. It introduces a portable object-oriented GUI framework, suitable for a declarative layout definition, components customization, and fine model-view code separation. It also rationalizes the hardware and software solutions selected for this project implementation.

  19. On-line classification of pollutants in water using wireless portable electronic noses.

    PubMed

    Herrero, José Luis; Lozano, Jesús; Santos, José Pedro; Suárez, José Ignacio

    2016-06-01

    A portable electronic nose with database connection for on-line classification of pollutants in water is presented in this paper. It is a hand-held, lightweight and powered instrument with wireless communications capable of standalone operation. A network of similar devices can be configured for distributed measurements. It uses four resistive microsensors and headspace as sampling method for extracting the volatile compounds from glass vials. The measurement and control program has been developed in LabVIEW using the database connection toolkit to send the sensors data to a server for training and classification with Artificial Neural Networks (ANNs). The use of a server instead of the microprocessor of the e-nose increases the capacity of memory and the computing power of the classifier and allows external users to perform data classification. To address this challenge, this paper also proposes a web-based framework (based on RESTFul web services, Asynchronous JavaScript and XML and JavaScript Object Notation) that allows remote users to train ANNs and request classification values regardless user's location and the type of device used. Results show that the proposed prototype can discriminate the samples measured (Blank water, acetone, toluene, ammonia, formaldehyde, hydrogen peroxide, ethanol, benzene, dichloromethane, acetic acid, xylene and dimethylacetamide) with a 94% classification success rate.

  20. Energy use of U.S. consumer electronics at the end of the 20th century

    SciTech Connect

    Rosen, Karen; Meier, Alan

    2000-08-31

    The major consumer electronics in U.S. homes accounted for over 10 percent of U.S. residential electricity consumption, which is comparable to the electricity consumed by refrigerators or lighting. We attribute 3.6 percent to video products, 3.3 percent to home office equipment, and 1.8 percent to audio products. Televisions use more energy than any other single product category, but computer energy use now ranks second and is likely to continue growing. In all, consumer electronics consumed 110 THw in the U.S. in 1999, over 60 percent of which was consumed while the products were not in use.

  1. 78 FR 71643 - Certain Wireless Consumer Electronics Devices and Components Thereof; Commission Determination To...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-29

    ... COMMISSION Certain Wireless Consumer Electronics Devices and Components Thereof; Commission Determination To... August 24, 2012, based on a complaint filed by Technology Properties Limited LLC and Phoenix Digital... of certain wireless consumer electronics devices and components thereof by reason of infringement...

  2. 77 FR 31876 - Certain Consumer Electronics and Display Devices and Products Containing Same Determination Not...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-30

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Certain Consumer Electronics and Display Devices and Products Containing Same Determination Not To... importation of certain consumer electronics and display devices and products containing the same by reason...

  3. A Simple and Portable Algorithm for Identifying Atrial Fibrillation in the Electronic Medical Record.

    PubMed

    Khurshid, Shaan; Keaney, John; Ellinor, Patrick T; Lubitz, Steven A

    2016-01-15

    Atrial fibrillation (AF) is common and increases stroke risk and mortality. Many knowledge gaps remain with respect to practice patterns and outcomes. Electronic medical records (EMRs) may serve as powerful research tools if AF status can be properly ascertained. We sought to develop an algorithm for identifying subjects with and without AF in the EMR and compare it to previous methods. Using a hospital network EMR (n = 5,737,846), we randomly selected 8,200 subjects seen at a large academic medical center in January 2014 to derive and validate 7 AF classification schemas (4 cases and 3 controls) to construct a composite AF algorithm. In an independent sample of 172,138 subjects, we compared this algorithm against published AF classification methods. In total, we performed manual adjudication of AF in 700 subjects. Three AF schemas (AF1, AF2, and AF4) achieved positive predictive value (PPV) >0.9. Two control schemas achieved PPV >0.9 (control 1 and control 3). A combination algorithm AF1, AF2, and AF4 (PPV 88%; 8.2% classified) outperformed published classification methods including >1 outpatient International Statistical Classification of Diseases, Ninth Revision code or 1 outpatient code with an electrocardiogram demonstrating AF (PPV 82%; 5.9% classified), ≥ 1 inpatient International Statistical Classification of Diseases, Ninth Revision code or electrocardiogram demonstrating AF (PPV 88%; 6.1% classified), or the intersection of these (PPV 84%; 7.4% classified). When applied simultaneously, the case and control algorithms classified 98.4% of the cohort with zero disagreement. In conclusion, we derived a parsimonious and portable algorithm to identify subjects with and without AF with high sensitivity. If broadly applied, this algorithm can provide optimal power for EMR-based AF research.

  4. Consumer electronic optics: how small can a lens be: the case of panomorph lenses

    NASA Astrophysics Data System (ADS)

    Thibault, Simon; Parent, Jocelyn; Zhang, Hu; Du, Xiaojun; Roulet, Patrice

    2014-09-01

    In 2014, miniature camera modules are applied to a variety of applications such as webcam, mobile phone, automotive, endoscope, tablets, portable computers and many other products. Mobile phone cameras are probably one of the most challenging parts due to the need for smaller and smaller total track length (TTL) and optimized embedded image processing algorithms. As the technology is developing, higher resolution and higher image quality, new capabilities are required to fulfil the market needs. Consequently, the lens system becomes more complex and requires more optical elements and/or new optical elements. What is the limit? How small an injection molded lens can be? We will discuss those questions by comparing two wide angle lenses for consumer electronic market. The first lens is a 6.56 mm (TTL) panoramic (180° FOV) lens built in 2012. The second is a more recent (2014) panoramic lens (180° FOV) with a TTL of 3.80 mm for mobile phone camera. Both optics are panomorph lenses used with megapixel sensors. Between 2012 and 2014, the development in design and plastic injection molding allowed a reduction of the TTL by more than 40%. This TTL reduction has been achieved by pushing the lens design to the extreme (edge/central air and material thicknesses as well as lens shape). This was also possible due to a better control of the injection molding process and material (low birefringence, haze and thermal stability). These aspects will be presented and discussed. During the next few years, we don't know if new material will come or new process but we will still need innovative people and industries to push again the limits.

  5. Consumers.

    PubMed

    Brophy, Lisa M; Roper, Catherine E; Hamilton, Bridget E; Tellez, Juan José; McSherry, Bernadette M

    2016-03-03

    Objective This paper examines the perspectives of consumers and their supporters regarding the use of seclusion and restraint in mental health settings.Methods Five focus groups for consumers and five focus groups for supporters were conducted in four Australian cities and in one rural location. The 66 participants were asked about strategies to reduce or eliminate the use of seclusion and restraint in mental health settings.Results All participants supported the reduction of the use of seclusion and restraint. Barriers to reducing these practices related to the environment, the effects of drug and alcohol issues, lack of a human rights focus and poor recognition of trauma, stigma and discrimination. Strategies for reducing or eliminating seclusion and restraint included workforce development, environmental and cultural changes.Conclusions Participants clearly identified that the status quo needs to change and conveyed urgency for action. Participants suggested that the involvement of supporters and a range of consumer roles are integral to reducing the use of seclusion and restraint. The findings support the current policy emphasis of working towards the elimination of these practices.What is known about the topic? Mental health policies across many jurisdictions support the reduction and elimination of restraint and seclusion. Evidence suggests those subjected to restraint and seclusion largely experience a range of harmful consequences. No studies focus on the views of supporters of consumers regarding the reduction and elimination of seclusion and restraint, whereas the views of consumers appear in a minority of international studies.What does this paper add? The research enabled an opportunity to hear from people who have been personally affected by and/or have lived experience of these coercive practices. Participants identified local reforms that can uphold the human rights of consumers. They suggested practices to increase accountability, peer support and

  6. Evaluation of a new optic-enabled portable X-ray fluorescence spectrometry instrument for measuring toxic metals/metalloids in consumer goods and cultural products

    NASA Astrophysics Data System (ADS)

    Guimarães, Diana; Praamsma, Meredith L.; Parsons, Patrick J.

    2016-08-01

    X-ray fluorescence spectrometry (XRF) is a rapid, non-destructive multi-elemental analytical technique used for determining elemental contents ranging from percent down to the μg/g level. Although detection limits are much higher for XRF compared to other laboratory-based methods, such as inductively coupled plasma mass spectrometry (ICP-MS), ICP-optical emission spectrometry (OES) and atomic absorption spectrometry (AAS), its portability and ease of use make it a valuable tool, especially for field-based studies. A growing necessity to monitor human exposure to toxic metals and metalloids in consumer goods, cultural products, foods and other sample types while performing the analysis in situ has led to several important developments in portable XRF technology. In this study, a new portable XRF analyzer based on the use of doubly curved crystal optics (HD Mobile®) was evaluated for detecting toxic elements in foods, medicines, cosmetics and spices used in many Asian communities. Two models of the HD Mobile® (a pre-production and a final production unit) were investigated. Performance parameters including accuracy, precision and detection limits were characterized in a laboratory setting using certified reference materials (CRMs) and standard solutions. Bias estimates for key elements of public health significance such as As, Cd, Hg and Pb ranged from - 10% to 11% for the pre-production, and - 14% to 16% for the final production model. Five archived public health samples including herbal medicine products, ethnic spices and cosmetic products were analyzed using both XRF instruments. There was good agreement between the pre-production and final production models for the four key elements, such that the data were judged to be fit-for-purpose for the majority of samples analyzed. Detection of the four key elements of interest using the HD Mobile® was confirmed using archived samples for which ICP-OES data were available based on digested sample materials. The HD

  7. Additive Manufacturing in Offsite Repair of Consumer Electronics

    NASA Astrophysics Data System (ADS)

    Chekurov, Sergei; Salmi, Mika

    Spare parts for products that are at the end of their life cycles, but still under warranty, are logistically difficult because they are commonly not stored in the central warehouse. These uncommon spare parts occupy valuable space in smaller inventories and take a long time to be transported to the point of need, thus delaying the repair process. This paper proposes that storing the spare parts on a server and producing them with additive manufacturing (AM) on demand can shorten the repair cycle by simplifying the logistics. Introducing AM in the repair supply chain lowers the number of products that need to be reimbursed to the customer due to lengthy repairs, improves the repair statistics of the repair shops, and reduces the number of items that are held in stock. For this paper, the functionality of the concept was verified by reverse engineering a memory cover of a portable computer and laser sintering it from polyamide 12. The additively manufactured component fit well and the computer operated normally after the replacement. The current spare part supply chain model and models with AM machinery located at the repair shop, the centralized spare part provider, and the original equipment manufacturer were provided. The durations of the repair process in the models were compared by simulating two scenarios with the Monte Carlo method. As the biggest improvement, the model with the AM machine in the repair shop reduced the duration of the repair process from 14 days to three days. The result points to the conclusion that placing the machine as close to the need as possible is the best option, if there is enough demand. The spare parts currently compatible with AM are plastic components without strict surface roughness requirements, but more spare parts will become compatible with the development of AM.

  8. 78 FR 12354 - Certain Wireless Consumer Electronics Devices and Components Thereof; Commission Determination...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-22

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Certain Wireless Consumer Electronics Devices and Components Thereof; Commission Determination Concerning an Initial Determination Granting a Motion To Amend Complaint and Notice of Investigation...

  9. Portable Electronic Nose System for Identification of Synthesized Gasoline Using Metal Oxide Gas Sensor and Pattern Recognition

    NASA Astrophysics Data System (ADS)

    Kim, Young Wung; Park, Hong Bae; Lee, In Soo; Cho, Jung Hwan

    2011-09-01

    This paper describes a portable electronic nose (e-nose) system for use in the identification of synthesized gasoline, comprised of a single semiconductor type of gas sensor and pattern recognition neural networks. The designed e-nose system consists of a one-chip microcontroller, a pre-concentrator, and a gas sensor. Two different neural networks, a multilayer perceptron (MLP) neural network and a fuzzy ARTMAP neural network were applied to discriminate synthesized gasoline from normal gasoline. The results of the classification showed 100% and 85% recognition rates for the training data set and testing data set, respectively.

  10. Ultralight Cut-Paper-Based Self-Charging Power Unit for Self-Powered Portable Electronic and Medical Systems.

    PubMed

    Guo, Hengyu; Yeh, Min-Hsin; Zi, Yunlong; Wen, Zhen; Chen, Jie; Liu, Guanlin; Hu, Chenguo; Wang, Zhong Lin

    2017-04-12

    The development of lightweight, superportable, and sustainable power sources has become an urgent need for most modern personal electronics. Here, we report a cut-paper-based self-charging power unit (PC-SCPU) that is capable of simultaneously harvesting and storing energy from body movement by combining a paper-based triboelectric nanogenerator (TENG) and a supercapacitor (SC), respectively. Utilizing the paper as the substrate with an assembled cut-paper architecture, an ultralight rhombic-shaped TENG is achieved with highly specific mass/volume charge output (82 nC g(-1)/75 nC cm(-3)) compared with the traditional acrylic-based TENG (5.7 nC g(-1)/5.8 nC cm(-3)), which can effectively charge the SC (∼1 mF) to ∼1 V in minutes. This wallet-contained PC-SCPU is then demonstrated as a sustainable power source for driving wearable and portable electronic devices such as a wireless remote control, electric watch, or temperature sensor. This study presents a potential paper-based portable SCPU for practical and medical applications.

  11. An Analog Multilayer Perceptron Neural Network for a Portable Electronic Nose

    PubMed Central

    Pan, Chih-Heng; Hsieh, Hung-Yi; Tang, Kea-Tiong

    2013-01-01

    This study examines an analog circuit comprising a multilayer perceptron neural network (MLPNN). This study proposes a low-power and small-area analog MLP circuit to implement in an E-nose as a classifier, such that the E-nose would be relatively small, power-efficient, and portable. The analog MLP circuit had only four input neurons, four hidden neurons, and one output neuron. The circuit was designed and fabricated using a 0.18 μm standard CMOS process with a 1.8 V supply. The power consumption was 0.553 mW, and the area was approximately 1.36 × 1.36 mm2. The chip measurements showed that this MLPNN successfully identified the fruit odors of bananas, lemons, and lychees with 91.7% accuracy. PMID:23262482

  12. Implementation of a portable electronic system for providing pain relief to patellofemoral pain syndrome patients

    NASA Astrophysics Data System (ADS)

    Chang Chien, Jia-Ren; Lin, Guo-Hong; Hsu, Ar-Tyan

    2011-10-01

    In this study, a portable electromyogram (EMG) system and a stimulator are developed for patellofemoral pain syndrome patients, with the objective of reducing the pain experienced by these patients; the patellar pain is caused by an imbalance between the vastus medialis obliquus (VMO) and the vastus lateralis (VL). The EMG measurement circuit and the electrical stimulation device proposed in this study are specifically designed for the VMO and the VL; they are capable of real-time waveform recording, possess analyzing functions, and can upload their measurement data to a computer for storage and analysis. The system can calculate and record the time difference between the EMGs of the VMO and the VL, as well as the signal strengths of both the EMGs. As soon as the system detects the generation of the EMG of the VL, it quickly calculates and processes the event and stimulates the VMO as feedback through electrical stimulation units, in order to induce its contraction. The system can adjust the signal strength, time length, and the sequence of the electrical stimulation, both manually and automatically. The output waveform of the electrical stimulation circuit is a dual-phase asymmetrical pulse waveform. The primary function of the electrical simulation circuit is to ensure that the muscles contract effectively. The performance of the device can be seen that the width of each pulse is 20-1000 μs, the frequency of each pulse is 10-100 Hz, and current strength is 10-60 mA.

  13. A wireless and portable electronic nose to differentiate musts of different ripeness degree and grape varieties.

    PubMed

    Aleixandre, Manuel; Santos, Jose Pedro; Sayago, Isabel; Cabellos, Juan Mariano; Arroyo, Teresa; Horrillo, Maria Carmen

    2015-04-13

    Two novel applications using a portable and wireless sensor system (e-nose) for the wine producing industry-The recognition and classification of musts coming from different grape ripening times and from different grape varieties-Are reported in this paper. These applications are very interesting because a lot of varieties of grapes produce musts with low and similar aromatic intensities so they are very difficult to distinguish using a sensory panel. Therefore the system could be used to monitor the ripening evolution of the different types of grapes and to assess some useful characteristics, such as the identification of the grape variety origin and to prediction of the wine quality. Ripening grade of collected samples have been also evaluated by classical analytical techniques, measuring physicochemical parameters, such as, pH, Brix, Total Acidity (TA) and Probable Grade Alcoholic (PGA). The measurements were carried out for two different harvests, using different red (Barbera, Petit Verdot, Tempranillo, and Touriga) and white (Malvar, Malvasía, Chenin Blanc, and Sauvignon Blanc) grape musts coming from the experimental cellar of the IMIDRA at Madrid. Principal Component Analysis (PCA) and Probabilistic Neural Networks (PNN) have been used to analyse the obtained data by e-nose. In addition, and the Canonical Correlation Analysis (CCA) method has been carried out to correlate the results obtained by both technologies.

  14. A Wireless and Portable Electronic Nose to Differentiate Musts of Different Ripeness Degree and Grape Varieties

    PubMed Central

    Aleixandre, Manuel; Santos, Jose Pedro; Sayago, Isabel; Cabellos, Juan Mariano; Arroyo, Teresa; Horrillo, Maria Carmen

    2015-01-01

    Two novel applications using a portable and wireless sensor system (e-nose) for the wine producing industry—The recognition and classification of musts coming from different grape ripening times and from different grape varieties—Are reported in this paper. These applications are very interesting because a lot of varieties of grapes produce musts with low and similar aromatic intensities so they are very difficult to distinguish using a sensory panel. Therefore the system could be used to monitor the ripening evolution of the different types of grapes and to assess some useful characteristics, such as the identification of the grape variety origin and to prediction of the wine quality. Ripening grade of collected samples have been also evaluated by classical analytical techniques, measuring physicochemical parameters, such as, pH, Brix, Total Acidity (TA) and Probable Grade Alcoholic (PGA). The measurements were carried out for two different harvests, using different red (Barbera, Petit Verdot, Tempranillo, and Touriga) and white (Malvar, Malvasía, Chenin Blanc, and Sauvignon Blanc) grape musts coming from the experimental cellar of the IMIDRA at Madrid. Principal Component Analysis (PCA) and Probabilistic Neural Networks (PNN) have been used to analyse the obtained data by e-nose. In addition, and the Canonical Correlation Analysis (CCA) method has been carried out to correlate the results obtained by both technologies. PMID:25871715

  15. The consumer's view of the electronic health record: engaging patients in EHR adoption.

    PubMed

    Cox, Barbara; Thornewill, Judah

    2008-01-01

    The consumer/patient perspective is often forgotten as it pertains to the electronic health record. This paper focused on engaging the patient in the adoption of EHRs. The Louisville Health Information Exchange (LouHIE) recently completed an extensive research study on this topic, using several data gathering techniques to capture the interest, benefits, concerns and payment choices of the community. This article focuses on the findings of the study and the steps LouHIE will take to ensure consumer perspectives are being heard. Specific elements of the article include explaining the consumer research study and results; discussing the patient-related benefits of an EHR, the barriers, interests and the payment choices as described by the research group; and discussing action steps needed to continue engaging the consumer/patient in the adoption process.

  16. A Comparison of Subjects' Reading and Writing Performance and Preference While Using Various Portable Electronic Magnifiers

    ERIC Educational Resources Information Center

    Matchinski, Tracy L.; Winters, Janis E.

    2016-01-01

    The ability to read print to help maintain independence and quality of life is a primary concern of people with visual impairments. One option for reading is a CCTV (closed-circuit television) or, using a more specific term, electronic magnifier. An electronic magnifier uses a camera to enlarge images onto a screen. The aim of this study was to…

  17. American Gadgets: Cybernetics, Consumer Electronics, and Twentieth-Century US Fiction

    ERIC Educational Resources Information Center

    Simeone, Michael

    2011-01-01

    Challenging the argument that liberal humanism faces extinction in the face of ubiquitous digital technologies, my dissertation analyzes the ways in which consumer electronics reinscribe the human subject as a privileged category in the information age. Through spaces like the Matrix, Windows 7, or even the single row of play controls on a…

  18. American Gadgets: Cybernetics, Consumer Electronics, and Twentieth-Century US Fiction

    ERIC Educational Resources Information Center

    Simeone, Michael

    2011-01-01

    Challenging the argument that liberal humanism faces extinction in the face of ubiquitous digital technologies, my dissertation analyzes the ways in which consumer electronics reinscribe the human subject as a privileged category in the information age. Through spaces like the Matrix, Windows 7, or even the single row of play controls on a…

  19. Building a Terabyte Memory Bandwidth Compute Node with Four Consumer Electronics GPUs

    NASA Astrophysics Data System (ADS)

    Omlin, Samuel; Räss, Ludovic; Podladchikov, Yuri

    2014-05-01

    GPUs released for consumer electronics are generally built with the same chip architectures as the GPUs released for professional usage. With regards to scientific computing, there are no obvious important differences in functionality or performance between the two types of releases, yet the price can differ up to one order of magnitude. For example, the consumer electronics release of the most recent NVIDIA Kepler architecture (GK110), named GeForce GTX TITAN, performed equally well in conducted memory bandwidth tests as the professional release, named Tesla K20; the consumer electronics release costs about one third of the professional release. We explain how to design and assemble a well adjusted computer with four high-end consumer electronics GPUs (GeForce GTX TITAN) combining more than 1 terabyte/s memory bandwidth. We compare the system's performance and precision with the one of hardware released for professional usage. The system can be used as a powerful workstation for scientific computing or as a compute node in a home-built GPU cluster.

  20. Portable reflectance spectrometer

    NASA Technical Reports Server (NTRS)

    Goetz, A. F. H.; Graham, R. A.; Ozawa, T. (Inventor)

    1977-01-01

    A portable reflectance spectrometer is disclosed. The spectrometer essentially includes an optical unit and an electronic recording unit. The optical unit includes a pair of thermoelectrically-cooled detectors, for detecting total radiance and selected radiance projected through a circular variable filter wheel, and is capable of operating to provide spectral data in the range 0.4 to 2.5 micrometers without requiring coventional substitution of filter elements. The electronic recording unit includes power supplies, amplifiers, and digital recording electronics designed to permit recordation of data on tape casettes. Both the optical unit and electronic recording unit are packaged to be manually portable.

  1. Electronic waste recovery in Finland: Consumers' perceptions towards recycling and re-use of mobile phones.

    PubMed

    Ylä-Mella, Jenni; Keiski, Riitta L; Pongrácz, Eva

    2015-11-01

    This paper examines consumers' awareness and perceptions towards mobile phone recycling and re-use. The results are based on a survey conducted in the city of Oulu, Finland, and analysed in the theoretical framework based on the theories of planned behaviour (TPB) and value-belief-norm (VBN). The findings indicate that consumers' awareness of the importance and existence of waste recovery system is high; however, awareness has not translated to recycling behaviour. The survey reveals that 55% of respondents have two or more unused mobile phones at homes. The more phones stored at homes, the more often reasons 'I don't know where to return' and/or 'have not got to do it yet' were mentioned. This indicates that proximity and the convenience of current waste management system are inadequate in promoting the return of small waste electrical and electronic equipment (WEEE). To facilitate re-use, and the highest level of recovery, consumers will need to be committed to return end-of-use electronics to WEEE collection centres without delays. Further, the supply and demand of refurbished mobile phones do not meet at this moment in Finland due to consumer's storing habits versus expectations of recent features under guarantee and unrealistic low prizes. The study also points out that, in order to change current storing habits of consumers, there is an explicit need for more information and awareness on mobile phone collection in Finland, especially on regarding retailers' take-back.

  2. A Literature Review of Word of Mouth and Electronic Word of Mouth: Implications for Consumer Behavior.

    PubMed

    Huete-Alcocer, Nuria

    2017-01-01

    The rise and spread of the Internet has led to the emergence of a new form of word of mouth (WOM): electronic word of mouth (eWOM), considered one of the most influential informal media among consumers, businesses, and the population at large. Drawing on these ideas, this paper reviews the relevant literature, analyzing the impact of traditional WOM and eWOM in the field of consumer behavior and highlighting the main differences between the two types of recommendations, with a view to contributing to a better understanding of the potential of both.

  3. A Literature Review of Word of Mouth and Electronic Word of Mouth: Implications for Consumer Behavior

    PubMed Central

    Huete-Alcocer, Nuria

    2017-01-01

    The rise and spread of the Internet has led to the emergence of a new form of word of mouth (WOM): electronic word of mouth (eWOM), considered one of the most influential informal media among consumers, businesses, and the population at large. Drawing on these ideas, this paper reviews the relevant literature, analyzing the impact of traditional WOM and eWOM in the field of consumer behavior and highlighting the main differences between the two types of recommendations, with a view to contributing to a better understanding of the potential of both. PMID:28790950

  4. Perceptions of chronically ill and healthy consumers about electronic personal health records: a comparative empirical investigation

    PubMed Central

    Cocosila, Mihail; Archer, Norm

    2014-01-01

    Objective To develop a model of consumer perceptions of electronic personal health records (PHRs) and validate it in a comparative study between consumers who report having a chronic illness and those who report being well. Materials and methods A model of PHR use motivators and barriers was built and tested through a national survey across Canada. Data were collected from 800 individuals, 18 years or older. Half reported having a chronic illness or disability and half reported being well. Analyses were performed with structural equation modelling techniques. Results A total of 389 answers from chronically ill and 383 from well participants were collected. Perceived usefulness was the key explanation of the intention to use PHRs for both ill and well people (total effect of 0.601 and 0.565, respectively) followed by security, privacy and trust in PHRs (total effect of 0.377 and 0.479, respectively). Conversely, computer anxiety was perceived as a significant barrier (total effect of −0.327 for ill individuals and −0.212 for well individuals). Discussion The model proposed was appropriate in explaining key consumer positive and negative perceptions on electronic PHR use. We found little difference in perceptions of electronic PHRs between chronically ill and well individuals, although self-reporting their health status might have influenced the results. Conclusions To increase the adoption rate of electronic PHRs among both chronically ill and well consumers it is necessary to reinforce consumer perceptions of the usefulness of and trust in these eHealth technologies while mitigating their anxieties about computer use in general. PMID:25056975

  5. Acetic acid detection threshold in synthetic wine samples of a portable electronic nose.

    PubMed

    Macías, Miguel Macías; Manso, Antonio García; Orellana, Carlos Javier García; Velasco, Horacio Manuel González; Caballero, Ramón Gallardo; Chamizo, Juan Carlos Peguero

    2012-12-24

    Wine quality is related to its intrinsic visual, taste, or aroma characteristics and is reflected in the price paid for that wine. One of the most important wine faults is the excessive concentration of acetic acid which can cause a wine to take on vinegar aromas and reduce its varietal character. Thereby it is very important for the wine industry to have methods, like electronic noses, for real-time monitoring the excessive concentration of acetic acid in wines. However, aroma characterization of alcoholic beverages with sensor array electronic noses is a difficult challenge due to the masking effect of ethanol. In this work, in order to detect the presence of acetic acid in synthetic wine samples (aqueous ethanol solution at 10% v/v) we use a detection unit which consists of a commercial electronic nose and a HSS32 auto sampler, in combination with a neural network classifier (MLP). To find the characteristic vector representative of the sample that we want to classify, first we select the sensors, and the section of the sensors response curves, where the probability of detecting the presence of acetic acid will be higher, and then we apply Principal Component Analysis (PCA) such that each sensor response curve is represented by the coefficients of its first principal components. Results show that the PEN3 electronic nose is able to detect and discriminate wine samples doped with acetic acid in concentrations equal or greater than 2 g/L.

  6. Acetic Acid Detection Threshold in Synthetic Wine Samples of a Portable Electronic Nose

    PubMed Central

    Macías, Miguel Macías; Manso, Antonio García; Orellana, Carlos Javier García; Velasco, Horacio Manuel González; Caballero, Ramón Gallardo; Chamizo, Juan Carlos Peguero

    2013-01-01

    Wine quality is related to its intrinsic visual, taste, or aroma characteristics and is reflected in the price paid for that wine. One of the most important wine faults is the excessive concentration of acetic acid which can cause a wine to take on vinegar aromas and reduce its varietal character. Thereby it is very important for the wine industry to have methods, like electronic noses, for real-time monitoring the excessive concentration of acetic acid in wines. However, aroma characterization of alcoholic beverages with sensor array electronic noses is a difficult challenge due to the masking effect of ethanol. In this work, in order to detect the presence of acetic acid in synthetic wine samples (aqueous ethanol solution at 10% v/v) we use a detection unit which consists of a commercial electronic nose and a HSS32 auto sampler, in combination with a neural network classifier (MLP). To find the characteristic vector representative of the sample that we want to classify, first we select the sensors, and the section of the sensors response curves, where the probability of detecting the presence of acetic acid will be higher, and then we apply Principal Component Analysis (PCA) such that each sensor response curve is represented by the coefficients of its first principal components. Results show that the PEN3 electronic nose is able to detect and discriminate wine samples doped with acetic acid in concentrations equal or greater than 2 g/L. PMID:23262483

  7. Design and Testing of the Variable Electronic Regulator (VER) for Portable Life Support System (PLSS) Development

    NASA Technical Reports Server (NTRS)

    Campbell, Colin; Pryzbyla, Ken

    2010-01-01

    The next generation space suit requires additional capabilities for controlling and adjusting internal pressure compared to that of historical designs. Next generation suit pressures will range from slight pressure, for astronaut prebreathe comfort, to hyperbaric pressure levels for emergency medical treatment of decompression sickness. Historical regulator designs for space suits have been purely mechanical in nature with the performance aspects typical of such designs such as droop. This paper discusses a new approach to providing the tighter regulation band possible with electronic regulation while mitigating the typical short-comings of electronic control: power consumption, loss of power failure modes, start-up time, and reliability. The paper will also address the bench top prototype development and subsequent performance testing with comparison back to mechanical regulators as a baseline.

  8. Browsing news and talk video on a consumer electronics platform using face detection

    NASA Astrophysics Data System (ADS)

    Peker, Kadir A.; Divakaran, Ajay; Lanning, Tom

    2005-10-01

    We present a consumer video browsing system that enables use of multiple alternative summaries in a simple and effective user interface suitable for consumer electronics platforms. We present a news and talk video segmentation and summary generation technique for this platform. We use face detection on consumer video, and use simple face features such as face count, size, and x-location to classify video segments. More specifically, we cluster 1-face segments using face sizes and x-locations. We observe that different scenes such as anchorperson, outdoor correspondent, weather report, etc. form separate clusters. We then apply temporal morphological filtering on the label streams to obtain alternative summary streams for smooth summaries and effective browsing through stories. We also apply our technique to talk show video to generate separate summaries of monologue segments and guest interviews.

  9. Portable Welder

    NASA Technical Reports Server (NTRS)

    1984-01-01

    A low cost, low power, self-contained portable welding gun designed for joining thermoplastics which become soft when heated and harden when cooled was developed originally by NASA's Langley Research Center for repairing helicopter windshields. Welder has a broad range of applications for joining both thermoplastic materials in the aerospace, automotive, appliance, and construction industries. Welders portability and low power requirement allow its use on-site in any type of climate, with power supplied by a variety of portable sources.

  10. A Practical and Portable Solids-State Electronic Terahertz Imaging System

    PubMed Central

    Smart, Ken; Du, Jia; Li, Li; Wang, David; Leslie, Keith; Ji, Fan; Li, Xiang Dong; Zeng, Da Zhang

    2016-01-01

    A practical compact solid-state terahertz imaging system is presented. Various beam guiding architectures were explored and hardware performance assessed to improve its compactness, robustness, multi-functionality and simplicity of operation. The system performance in terms of image resolution, signal-to-noise ratio, the electronic signal modulation versus optical chopper, is evaluated and discussed. The system can be conveniently switched between transmission and reflection mode according to the application. A range of imaging application scenarios was explored and images of high visual quality were obtained in both transmission and reflection mode. PMID:27110791

  11. Electronic and software systems of an automated portable static mass spectrometer

    NASA Astrophysics Data System (ADS)

    Chichagov, Yu. V.; Bogdanov, A. A.; Lebedev, D. S.; Kogan, V. T.; Tubol'tsev, Yu. V.; Kozlenok, A. V.; Moroshkin, V. S.; Berezina, A. V.

    2017-01-01

    The electronic systems of a small high-sensitivity static mass spectrometer and software and hardware tools, which allow one to determine trace concentrations of gases and volatile compounds in air and water samples in real time, have been characterized. These systems and tools have been used to set up the device, control the process of measurement, synchronize this process with accompanying measurements, maintain reliable operation of the device, process the obtained results automatically, and visualize and store them. The developed software and hardware tools allow one to conduct continuous measurements for up to 100 h and provide an opportunity for personnel with no special training to perform maintenance on the device. The test results showed that mobile mass spectrometers for geophysical and medical research, which were fitted with these systems, had a determination limit for target compounds as low as several ppb(m) and a mass resolving power (depending on the current task) as high as 250.

  12. Courseware Portability.

    ERIC Educational Resources Information Center

    Fletcher, J. D.

    Portability enables interactive courseware (ICW) and associated application programs to operate on computer-based systems other than the ones on which they are developed. Courseware portability will increase sharing of ICW across a range of instructional settings within military services and across internationally allied military services. The…

  13. The potential of a portable, point-of-care electronic nose to diagnose tuberculosis.

    PubMed

    Coronel Teixeira, Rosarito; Rodríguez, Mabel; Jiménez de Romero, Nilda; Bruins, Marcel; Gómez, Roscio; Yntema, Jan Bart; Chaparro Abente, Gilberto; Gerritsen, Jan Willem; Wiegerinck, Wim; Pérez Bejerano, Domingo; Magis-Escurra, Cecile

    2017-08-10

    Tuberculosis (TB) is the leading cause of death due to an infectious disease worldwide. Especially in low-income countries, new diagnostic techniques that are accessible, inexpensive and easy-to-use, are needed to shorten transmission time and initiate treatment earlier. We conducted a study with a handheld, point-of-care electronic nose (eNose) device to diagnose TB through exhaled breath. This study includes a total of 110 patients and visitors of an expert centre of respiratory diseases in Asunción, Paraguay. TB diagnosis was established by culture of Mycobacterium tuberculosis complex and compared with the eNose results in two phases. The calibration phase, including only culture confirmed TB cases versus healthy people, demonstrated a sensitivity and specificity of 91% and 93% respectively. The confirmation phase, including all participants, showed a sensitivity of 88% and a specificity of 92%. The eNose showed high acceptance rate among participants, and was easy to operate. The eNose resulted in a powerful technique to differentiate between healthy people and TB patients. Its comfort, speed and usability promise great potential in vulnerable groups, in remote areas and hospital settings to triage patients with suspicion of TB. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  14. Development of portable mass spectrometer with electron cyclotron resonance ion source for detection of chemical warfare agents in air.

    PubMed

    Urabe, Tatsuya; Takahashi, Kazuya; Kitagawa, Michiko; Sato, Takafumi; Kondo, Tomohide; Enomoto, Shuichi; Kidera, Masanori; Seto, Yasuo

    2014-01-01

    A portable mass spectrometer with an electron cyclotron resonance ion source (miniECRIS-MS) was developed. It was used for in situ monitoring of trace amounts of chemical warfare agents (CWAs) in atmospheric air. Instrumental construction and parameters were optimized to realize a fast response, high sensitivity, and a small body size. Three types of CWAs, i.e., phosgene, mustard gas, and hydrogen cyanide were examined to check if the mass spectrometer was able to detect characteristic elements and atomic groups. From the results, it was found that CWAs were effectively ionized in the miniECRIS-MS, and their specific signals could be discerned over the background signals of air. In phosgene, the signals of the 35Cl+ and 37Cl+ ions were clearly observed with high dose-response relationships in the parts-per-billion level, which could lead to the quantitative on-site analysis of CWAs. A parts-per-million level of mustard gas, which was far lower than its lethal dosage (LCt50), was successfully detected with a high signal-stability of the plasma ion source. It was also found that the chemical forms of CWAs ionized in the plasma, i.e., monoatomic ions, fragment ions, and molecular ions, could be detected, thereby enabling the effective identification of the target CWAs. Despite the disadvantages associated with miniaturization, the overall performance (sensitivity and response time) of the miniECRIS-MS in detecting CWAs exceeded those of sector-type ECRIS-MS, showing its potential for on-site detection in the future. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. From electronic consumer products to e-wastes: Global outlook, waste quantities, recycling challenges.

    PubMed

    Tansel, Berrin

    2017-01-01

    Advancements in technology, materials development, and manufacturing processes have changed the consumer products and composition of municipal solid waste (MSW) since 1960s. Increasing quantities of discarded consumer products remain a major challenge for recycling efforts, especially for discarded electronic products (also referred as e-waste). The growing demand for high tech products has increased the e-waste quantities and its cross boundary transport globally. This paper reviews the challenges associated with increasing e-waste quantities. The increasing need for raw materials (especially for rare earth and minor elements) and unregulated e-waste recycling operations in developing and underdeveloped counties contribute to the growing concerns for e-waste management. Although the markets for recycled materials are increasing; there are major challenges for development of the necessary infrastructure for e-waste management and accountability as well as development of effective materials recovery technologies and product design.

  16. High-performance green flexible electronics based on biodegradable cellulose nanofibril paper

    Treesearch

    Yei Hwan Jung; Tzu-Hsuan Chang; Huilong Zhang; Chunhua Yao; Qifeng Zheng; Vina W. Yang; Hongyi Mi; Munho Kim; Sang June Cho; Dong-Wook Park; Hao Jiang; Juhwan Lee; Yijie Qiu; Weidong Zhou; Zhiyong Cai; Shaoqin Gong; Zhenqiang Ma

    2015-01-01

    Today’s consumer electronics, such as cell phones, tablets and other portable electronic devices, are typically made of non-renewable, non-biodegradable, and sometimes potentially toxic (for example, gallium arsenide) materials. These consumer electronics are frequently upgraded or discarded, leading to serious environmental contamination. Thus, electronic systems...

  17. Portable Planetarium.

    ERIC Educational Resources Information Center

    Stockdale, Dennis L.

    1997-01-01

    Describes a method that students can use to build portable planetariums. After building the models, students are familiar with the names of constellations and major stars and are able to share their projects with other students. (DDR)

  18. Consumer Electronics Testing to Fast-Rise EMP (Electromagnetic Pulse) (VEMPS (Vertical Electromagnetic Pulse Simulator) 2 Development)

    DTIC Science & Technology

    1989-06-01

    complete descrip- tion of all test configurations used at FEMPS, see Erler and Dancz [7]. Three types of test data were collected throughout the test...under HDL contract DAAL02-87-C-0052 (November 1987). 7. J. Erler and J. Dancz, Consumer Electronics Updated Test Plan, Sci- ence Applications...International Corporation, SAIC-102-87-021, under HDL contract DAAL02-86-D-0041 (15 July 1987). 8. J. Erler and W. Byers, FEMPS Consumer Electronics Tests

  19. A methodology for evaluating the usability of audiovisual consumer electronic products.

    PubMed

    Kwahk, Jiyoung; Han, Sung H

    2002-09-01

    Usability evaluation is now considered an essential procedure in consumer product development. Many studies have been conducted to develop various techniques and methods of usability evaluation hoping to help the evaluators choose appropriate methods. However, planning and conducting usability evaluation requires considerations of a number of factors surrounding the evaluation process including the product, user, activity, and environmental characteristics. In this perspective, this study suggested a new methodology of usability evaluation through a simple, structured framework. The framework was outlined by three major components: the interface features of a product as design variables, the evaluation context consisting of user, product, activity, and environment as context variables, and the usability measures as dependent variables. Based on this framework, this study established methods to specify the product interface features, to define evaluation context, and to measure usability. The effectiveness of this methodology was demonstrated through case studies in which the usability of audiovisual products was evaluated by using the methods developed in this study. This study is expected to help the usability practitioners in consumer electronics industry in various ways. Most directly, it supports the evaluators' plan and conduct usability evaluation sessions in a systematic and structured manner. In addition, it can be applied to other categories of consumer products (such as appliances, automobiles, communication devices, etc.) with minor modifications as necessary.

  20. Evolution of MEMS scanning mirrors for laser projection in compact consumer electronics

    NASA Astrophysics Data System (ADS)

    Tauscher, Jason; Davis, Wyatt O.; Brown, Dean; Ellis, Matt; Ma, Yunfei; Sherwood, Michael E.; Bowman, David; Helsel, Mark P.; Lee, Sung; Coy, John Wyatt

    2010-02-01

    The applicability of MOEMS scanning mirrors towards the creation of "flying spot" scanned laser displays is well established. The extension of this concept towards compact embedded pico-projectors has required an evolution of scanners and packaging to accommodate the needs of the consumer electronics space. This paper describes the progression of the biaxial MOEMS scanning mirrors developed by Microvision over recent years. Various aspects of the individual designs are compared. Early devices used a combination of magnetic quasistatic actuation and resonant electrostatic operation in an evacuated atmosphere to create a projection engine for retinal scanned displays. Subsequent designs realized the elimination of both the high voltage electrostatic drive and the vacuum package, and a simplification of the actuation scheme through proprietary technical advances. Additional advances have doubled the scan angle capability and greatly miniaturized the MOEMS component while not incurring significant increase in power consumption, making it an excellent fit for the consumer pico-projector application. The simplicity of the scanned laser-based pico-projector optical design enables high resolution and a large effective image size in a thin projection engine, all of which become critical both to the viability of the technology and adoption by consumers. Microvision's first scanned laser pico-projector is built around a MOEMS scanning mirror capable of projecting 16:9 aspect ratio, WVGA display within a 6.6 mm high package. Further evolution on this path promises continued improvement in resolution, size, and power.

  1. Portable dynamic fundus instrument

    NASA Technical Reports Server (NTRS)

    Taylor, Gerald R. (Inventor); Meehan, Richard T. (Inventor); Hunter, Norwood R. (Inventor); Caputo, Michael P. (Inventor); Gibson, C. Robert (Inventor)

    1992-01-01

    A portable diagnostic image analysis instrument is disclosed for retinal funduscopy in which an eye fundus image is optically processed by a lens system to a charge coupled device (CCD) which produces recordable and viewable output data and is simultaneously viewable on an electronic view finder. The fundus image is processed to develop a representation of the vessel or vessels from the output data.

  2. Bromine in plastic consumer products - Evidence for the widespread recycling of electronic waste.

    PubMed

    Turner, Andrew; Filella, Montserrat

    2017-12-01

    A range of plastic consumer products and components thereof have been analysed by x-ray fluorescence (XRF) spectrometry in a low density mode for Br as a surrogate for brominated flame retardant (BFR) content. Bromine was detected in about 42% of 267 analyses performed on electronic (and electrical) samples and 18% of 789 analyses performed on non-electronic samples, with respective concentrations ranging from 1.8 to 171,000μgg(-1) and 2.6 to 28,500μgg(-1). Amongst the electronic items, the highest concentrations of Br were encountered in relatively small appliances, many of which predated 2005 (e.g. a fan heater, boiler thermostat and smoke detector, and various rechargers, light bulb collars and printed circuit boards), and usually in association with Sb, a component of antimony oxide flame retardant synergists, and Pb, a heavy metal additive and contaminant. Amongst the non-electronic samples, Br concentrations were highest in items of jewellery, a coffee stirrer, a child's puzzle, a picture frame, and various clothes hangers, Christmas decorations and thermos cup lids, and were often associated with the presence of Sb and Pb. These observations, coupled with the presence of Br at concentrations below those required for flame-retardancy in a wider range of electronic and non-electronic items, are consistent with the widespread recycling of electronic plastic waste. That most Br-contaminated items were black suggests the current and recent demand for black plastics in particular is met, at least partially, through this route. Given many Br-contaminated items would evade the attention of the end-user and recycler, their disposal by conventional municipal means affords a course of BFR entry into the environment and, for food-contact items, a means of exposure to humans. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. The market of electrical and electronic equipment waste in Portugal: Analysis of take-back consumers' decisions.

    PubMed

    Botelho, Anabela; Ferreira Dias, Marta; Ferreira, Carla; Pinto, Lígia M Costa

    2016-10-01

    This paper aims to ascertain the efficacy and acceptability of five incentive schemes for the take-back of waste electrical and electronic equipment in Portugal, focusing in consumers' perspectives. It assesses users' perception of these items, evaluating the motivations and interests they have concerning the market of waste electrical and electronic equipment. Results indicate, on one hand, a lack of awareness by consumers about the process of take-back of their equipment. On the other hand, results show that information conditions and socio-demographic factors affect consumers' motivations for returning the electrical and electronic equipment at the end of life. In this context, it can be concluded that, in Portugal, the market for the recovery of waste electrical and electronic equipment is still in its infancy.

  4. Portable Electromyograph

    NASA Technical Reports Server (NTRS)

    De Luca, Gianluca; De Luca, Carlo J.; Bergman, Per

    2004-01-01

    A portable electronic apparatus records electromyographic (EMG) signals in as many as 16 channels at a sampling rate of 1,024 Hz in each channel. The apparatus (see figure) includes 16 differential EMG electrodes (each electrode corresponding to one channel) with cables and attachment hardware, reference electrodes, an input/output-and-power-adapter unit, a 16-bit analog-to-digital converter, and a hand-held computer that contains a removable 256-MB flash memory card. When all 16 EMG electrodes are in use, full-bandwidth data can be recorded in each channel for as long as 8 hours. The apparatus is powered by a battery and is small enough that it can be carried in a waist pouch. The computer is equipped with a small screen that can be used to display the incoming signals on each channel. Amplitude and time adjustments of this display can be made easily by use of touch buttons on the screen. The user can also set up a data-acquisition schedule to conform to experimental protocols or to manage battery energy and memory efficiently. Once the EMG data have been recorded, the flash memory card is removed from the EMG apparatus and placed in a flash-memory- card-reading external drive unit connected to a personal computer (PC). The PC can then read the data recorded in the 16 channels. Preferably, before further analysis, the data should be stored in the hard drive of the PC. The data files are opened and viewed on the PC by use of special- purpose software. The software for operation of the apparatus resides in a random-access memory (RAM), with backup power supplied by a small internal lithium cell. A backup copy of this software resides on the flash memory card. In the event of loss of both main and backup battery power and consequent loss of this software, the backup copy can be used to restore the RAM copy after power has been restored. Accessories for this device are also available. These include goniometers, accelerometers, foot switches, and force gauges.

  5. Process analysis of recycled thermoplasts from consumer electronics by laser-induced plasma spectroscopy.

    PubMed

    Fink, Herbert; Panne, Ulrich; Niessner, Reinhard

    2002-09-01

    An experimental setup for direct elemental analysis of recycled thermoplasts from consumer electronics by laser-induced plasma spectroscopy (LIPS, or laser-induced breakdown spectroscopy, LIBS) was realized. The combination of a echelle spectrograph, featuring a high resolution with a broad spectral coverage, with multivariate methods, such as PLS, PCR, and variable subset selection via a genetic algorithm, resulted in considerable improvements in selectivity and sensitivity for this complex matrix. With a normalization to carbon as internal standard, the limits of detection were in the ppm range. A preliminary pattern recognition study points to the possibility of polymer recognition via the line-rich echelle spectra. Several experiments at an extruder within a recycling plant demonstrated successfully the capability of LIPS for different kinds of routine on-line process analysis.

  6. How consumers evaluate eWOM (electronic word-of-mouth) messages.

    PubMed

    Doh, Sun-Jae; Hwang, Jang-Sun

    2009-04-01

    This experiment explored how consumers evaluate electronic word-of-mouth (eWOM) messages about products. Each participant was exposed a 10-message set in a single board. Five groups were manipulated in terms of their ratios of positive and negative messages. The result showed significant differences across various sets of eWOM messages. Although more positive sets showed higher scores in many cases, this was not true in all situations, especially for the case of credibility. Involvement and prior knowledge partially moderated the relationship between the ratio of messages and the eWOM effect. The credibility of Web sites and eWOM messages can be damaged in the long run if all of the eWOM messages are positive.

  7. The Economics of Educational Software Portability.

    ERIC Educational Resources Information Center

    Oliveira, Joao Batista Araujo e

    1990-01-01

    Discusses economic issues that affect the portability of educational software. Topics discussed include economic reasons for portability, including cost effectiveness; the nature and behavior of educational computer software markets; the role of producers, buyers, and consumers; potential effects of government policies; computer piracy; and…

  8. The Economics of Educational Software Portability.

    ERIC Educational Resources Information Center

    Oliveira, Joao Batista Araujo e

    1990-01-01

    Discusses economic issues that affect the portability of educational software. Topics discussed include economic reasons for portability, including cost effectiveness; the nature and behavior of educational computer software markets; the role of producers, buyers, and consumers; potential effects of government policies; computer piracy; and…

  9. Electronic Health Record Patient Portal Adoption by Health Care Consumers: An Acceptance Model and Survey

    PubMed Central

    2016-01-01

    Background The future of health care delivery is becoming more citizen centered, as today’s user is more active, better informed, and more demanding. Worldwide governments are promoting online health services, such as electronic health record (EHR) patient portals and, as a result, the deployment and use of these services. Overall, this makes the adoption of patient-accessible EHR portals an important field to study and understand. Objective The aim of this study is to understand the factors that drive individuals to adopt EHR portals. Methods We applied a new adoption model using, as a starting point, Ventkatesh's Unified Theory of Acceptance and Use of Technology in a consumer context (UTAUT2) by integrating a new construct specific to health care, a new moderator, and new relationships. To test the research model, we used the partial least squares (PLS) causal modelling approach. An online questionnaire was administrated. We collected 360 valid responses. Results The statistically significant drivers of behavioral intention are performance expectancy (beta=.200; t=3.619), effort expectancy (beta=.185; t=2.907), habit (beta=.388; t=7.320), and self-perception (beta=.098; t=2.285). The predictors of use behavior are habit (beta=0.206; t=2.752) and behavioral intention (beta=0.258; t=4.036). The model explained 49.7% of the variance in behavioral intention and 26.8% of the variance in use behavior. Conclusions Our research helps to understand the desired technology characteristics of EHR portals. By testing an information technology acceptance model, we are able to determine what is more valued by patients when it comes to deciding whether to adopt EHR portals or not. The inclusion of specific constructs and relationships related to the health care consumer area also had a significant impact on understanding the adoption of EHR portals. PMID:26935646

  10. 77 FR 67290 - Basic Service Tier Encryption Compatibility Between Cable Systems and Consumer Electronics Equipment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-09

    ... COMMISSION 47 CFR Part 76 Basic Service Tier Encryption Compatibility Between Cable Systems and Consumer...-digital systems, provided that those cable operators undertake certain consumer protection measures for a... Commission's Consumer and Governmental Affairs Bureau at (202) 418- 0530 (voice), (202) 418-0432 (TTY...

  11. e-Consent: The design and implementation of consumer consent mechanisms in an electronic environment.

    PubMed

    Coiera, Enrico; Clarke, Roger

    2004-01-01

    The effective coordination of health care relies on communication of confidential information about consumers between different health and community care services. However, consumers must be able to give or withhold "e-Consent" to those who wish to access their electronic health information. There are several possible forms for e-Consent. In the general consent model, a patient provides blanket consent for access to his or her information by an organization for all future information requests. Conversely, general denial explicitly denies consent for information to be used in future circumstances, and in each new episode of care, a new consent would be needed to obtain information. In the general consent with specific denial model, a patient attaches specific exclusion conditions to his or her general approval to future accesses. In contrast, in the general denial with explicit consent model, a patient issues a blanket block on all future accesses but allows the inclusion of future use under specified conditions. There also are several alternative functions for an e-Consent system. Consent could be captured as a matter of legal record. E-Consent systems could be more active by prompting clinicians to indicate that they have noted consent conditions before they access a record. Finally, the record of patient consent could be fully active and used as a gatekeeper in a distributed information environment. There probably will need to be some form of data object that is associated with patient information. This e-Consent object (or e-Co) will contain the specific conditions under which the data to which it is attached can be retrieved. Given the complexity of clinical work and the substantial variation we can expect in an individual's desire to make his or her personal medical details available, it is unlikely a "one size fits all" approach to e-Consent will work. Consequently, with a well-chosen consent design, it should be possible to balance the specific need for

  12. Health-hazard evaluation report HETA 90-223-2211, Thomson Consumer Electronics, Marion, Indiana

    SciTech Connect

    Lenhart, S.W.; Driscoll, R.

    1992-05-01

    In response to a request from the Corporate Medical Consultant to Thomson Consumer Electronics (SIC-3673), Marion, Indiana, a study was undertaken of an illness outbreak in workers at the facility. There were about 1900 workers at the facility, which produced television picture tubes. Production occurred over three shifts, 6 days a week. Charcoal tube sampling indicated the presence of acetone (67641) n-amyl-acetate (628637), n-butyl-acetate (123864), isoamyl-acetate (123922), toluene (108883), 1,1,1-trichloroethane (71556), and trichloroethylene (79016). No contaminants were detected in the bag samples of air collected from the in/house compressed air system. One or more symptoms were reported by 593 (82%) of the workers. Those most commonly reported included headache (68%), sore throat (53%), fatigue (51%), eye irritation (50%), itchy skin (47%), irritated nose (45%), dizziness (45%), unusual taste in mouth (45%), unusual smell (41%) and cough. The authors conclude that symptoms were consistent with stress related health complaints in occupational settings. Concentrations of chemicals measured in the facility would not be expected to produce the effects seen in the outbreak. The authors recommend that trichloroethylene degreasing units be replaced with equipment which uses a less toxic degreasing agent. The facility should hire a full time industrial hygienist.

  13. Consumption-weighted life cycle assessment of a consumer electronic product community.

    PubMed

    Ryen, Erinn G; Babbitt, Callie W; Williams, Eric

    2015-02-17

    A new approach for quantifying the net environmental impact of a "community" of interrelated products is demonstrated for consumer electronics owned by an average U.S. household over a 15-year period (1992-2007). This consumption-weighted life cycle assessment (LCA) methodology accounts for both product consumption (number of products per household) and impact (cumulative energy demand (MJ) and greenhouse gas emissions (MT CO2 eq) per product), analyzed using a hybrid LCA framework. Despite efficiency improvements in individual devices from 1992 to 2007, the net impact of the entire product community increased, due primarily to increasing ownership and usage. The net energy impact for the product community is significant, nearly 30% of the average gasoline use in a U.S. passenger vehicle in 2007. The analysis points to a large contribution by legacy products (cathode ray tube televisions and desktop computers), due to historically high consumption rates, although impacts are beginning to shift to smaller mobile devices. This method is also applied to evaluate prospective intervention strategies, indicating that environmental impact can be reduced by strategies such as lifespan extension or energy efficiency, but only when applied to all products owned, or by transforming consumption trends toward fewer, highly multifunctional products.

  14. Using consumer electronic devices to estimate whole-body vibration exposure.

    PubMed

    Wolfgang, Rebecca; Burgess-Limerick, Robin

    2014-01-01

    The cost and complexity of commercially available devices for measuring whole-body vibration is a barrier to the systematic collection of the information required to manage this hazard at workplaces. The potential for a consumer electronic device to be used to estimate whole-body vibration was assessed by use of an accelerometer calibrator, and by collecting 42 simultaneous pairs of measurements from a fifth-generation iPod Touch and one of two gold standard vibration measurement devices (Svantech SV111 [Svantech, Warsaw, Poland] or Brüel & Kjær 4447 [Brüel & Kjær Sound & Vibration Measurement A/S, Nærum, Denmark]) while driving light vehicles on a variety of different roadway surfaces. While sampling rate limitations make the accelerometer data collected from the iPod Touch unsuitable for frequency analysis, the vibration amplitudes recorded are sufficiently accurate (errors less than 0.1 m/s(2)) to assist workplaces manage whole-body vibration exposures.

  15. On the ability of consumer electronics microphones for environmental noise monitoring.

    PubMed

    Van Renterghem, Timothy; Thomas, Pieter; Dominguez, Frederico; Dauwe, Samuel; Touhafi, Abdellah; Dhoedt, Bart; Botteldooren, Dick

    2011-03-01

    The massive production of microphones for consumer electronics, and the shift from dedicated processing hardware to PC-based systems, opens the way to build affordable, extensive noise measurement networks. Applications include e.g. noise limit and urban soundscape monitoring, and validation of calculated noise maps. Microphones are the critical components of such a network. Therefore, in a first step, some basic characteristics of 8 microphones, distributed over a wide range of price classes, were measured in a standardized way in an anechoic chamber. In a next step, a thorough evaluation was made of the ability of these microphones to be used for environmental noise monitoring. This was done during a continuous, half-year lasting outdoor experiment, characterized by a wide variety of meteorological conditions. While some microphones failed during the course of this test, it was shown that it is possible to identify cheap microphones that highly correlate to the reference microphone during the full test period. When the deviations are expressed in total A-weighted (road traffic) noise levels, values of less than 1 dBA are obtained, in excess to the deviation amongst reference microphones themselves.

  16. Applying the French Minitel Model to U.S. Consumer Videotex: The Case of the Electronic Directory Service.

    ERIC Educational Resources Information Center

    Dupagne, Michel

    In view of the recent deregulatory developments in the United States' telecommunications industry, it is useful to reassess the issue of consumer videotex, especially as it relates to the implementation of electronic directory services. The success of the French videotex network Minitel relies on 10 principles: (1) cost of terminals; (2) no-frills…

  17. Analyzing the Environmental Impacts of Laptop Enclosures Using Screening-Level Life Cycle Assessment to Support Sustainable Consumer Electronics

    EPA Science Inventory

    With the ever-increasing amount of consumer electronics in service, it is essential industries and policy-makers work together to develop ways to manufacture more environmentally sustainable IT products which meet the needs of society. The objective of this study was to better un...

  18. Analyzing the Environmental Impacts of Laptop Enclosures Using Screening-Level Life Cycle Assessment to Support Sustainable Consumer Electronics

    EPA Science Inventory

    With the ever-increasing amount of consumer electronics in service, it is essential industries and policy-makers work together to develop ways to manufacture more environmentally sustainable IT products which meet the needs of society. The objective of this study was to better un...

  19. Benefits and Risks of Electronic Medical Record (EMR): An Interpretive Analysis of Healthcare Consumers' Perceptions of an Evolving Health Information Systems Technology

    ERIC Educational Resources Information Center

    Thompson, Chester D.

    2013-01-01

    The purpose of this study is to explore healthcare consumers' perceptions of their Electronic Medical Records (EMRs). Although there have been numerous studies regarding EMRs, there have been minimal, if any, research that explores healthcare consumers' awareness of this technology and the social implications that result. As consumers' health…

  20. Benefits and Risks of Electronic Medical Record (EMR): An Interpretive Analysis of Healthcare Consumers' Perceptions of an Evolving Health Information Systems Technology

    ERIC Educational Resources Information Center

    Thompson, Chester D.

    2013-01-01

    The purpose of this study is to explore healthcare consumers' perceptions of their Electronic Medical Records (EMRs). Although there have been numerous studies regarding EMRs, there have been minimal, if any, research that explores healthcare consumers' awareness of this technology and the social implications that result. As consumers' health…

  1. Improving quality of care and long-term health outcomes through continuity of care with the use of an electronic or paper patient-held portable health file (COMMUNICATE): study protocol for a randomized controlled trial.

    PubMed

    Lassere, Marissa Nichole; Baker, Sue; Parle, Andrew; Sara, Anthony; Johnson, Kent Robert

    2015-06-04

    The advantages of patient-held portable health files (PHF) and personal health records (PHR), paper or electronic, are said to include improved health-care provider continuity-of-care and patient empowerment in maintaining health. Top-down approaches are favored by public sector government and health managers. Bottom-up approaches include systems developed directly by health-care providers, consumers and industry, implemented locally on devices carried by patient-consumers or shared via web-based portals. These allow individuals to access, manage and share their health information, and that of others for whom they are authorized, in a private, secure and confidential environment. Few medical record technologies have been evaluated in randomized trials to determine whether there are important clinical benefits of these interventions. The COMMUNICATE trial will assess the acceptability and long-term clinical outcomes of an electronic and paper patient-held PHF. This is a 48-month, open-label pragmatic, superiority, parallel-group design randomized controlled trial. Subjects (n = 792) will be randomized in a 1:1:1 ratio to each of the trial arms: the electronic PHF added to usual care, the paper PHF added to usual care and usual care alone (no PHF). Inclusion criteria include those 60 years or older living independently in the community, but who have two or more chronic medical conditions that require prescription medication and regular care by at least three medical practitioners (general and specialist care). The primary objective is whether use of a PHF compared to usual care reduces a combined endpoint of deaths, overnight hospitalizations and blindly adjudicated serious out-of-hospital events. All primary analyses will be undertaken masked to randomized arm allocation using intention-to-treat principles. Secondary outcomes include quality of life and health literacy improvements. Lack of blinding creates potential for bias in trial conduct and ascertainment of

  2. Analyzing the environmental impacts of laptop enclosures using screening-level life cycle assessment to support sustainable consumer electronics (j/a)

    EPA Science Inventory

    The market growth of consumer electronics makes it essential for industries and policy-makers to work together to develop sustainable products. The objective of this study is to better understand how to promote environmentally sustainable consumer electronics by examining the use...

  3. Analyzing the environmental impacts of laptop enclosures using screening-level life cycle assessment to support sustainable consumer electronics (j/a)

    EPA Science Inventory

    The market growth of consumer electronics makes it essential for industries and policy-makers to work together to develop sustainable products. The objective of this study is to better understand how to promote environmentally sustainable consumer electronics by examining the use...

  4. An Overview of the Use of Phase Change Materials for the Thermal Management of Transient Portable Electronics: Benefits and Challenges

    NASA Astrophysics Data System (ADS)

    Fleischer, Amy S.

    This paper provides an overview of the implementation of phase change materials to absorb thermal energy in transient electronics. A thorough review of existing literature is included with an emphasis on the evolution of the technology, its potential benefits and the remaining challenges to its implementation.

  5. Building the electronic industry's roadmaps

    NASA Technical Reports Server (NTRS)

    Boulton, William R.

    1995-01-01

    JTEC panelists found a strong consistency among the electronics firms they visited: all the firms had clear visions or roadmaps for their research and development activities and had committed resources to ensure that they achieve targeted results. The overarching vision driving Japan's electronics industry is that of achieving market success through developing appealing, high-quality, low-cost consumer goods - ahead of the competition. Specifics of the vision include improving performance, quality, and portability of consumer electronics products. Such visions help Japanese companies define in detail the roadmaps they will follow to develop new and improved electronic packaging technologies.

  6. Building the electronic industry's roadmaps

    NASA Technical Reports Server (NTRS)

    Boulton, William R.

    1995-01-01

    JTEC panelists found a strong consistency among the electronics firms they visited: all the firms had clear visions or roadmaps for their research and development activities and had committed resources to ensure that they achieve targeted results. The overarching vision driving Japan's electronics industry is that of achieving market success through developing appealing, high-quality, low-cost consumer goods - ahead of the competition. Specifics of the vision include improving performance, quality, and portability of consumer electronics products. Such visions help Japanese companies define in detail the roadmaps they will follow to develop new and improved electronic packaging technologies.

  7. Audiotex Information Systems: Answering Consumer Queries Electronically. TDC Research Report No. 5.

    ERIC Educational Resources Information Center

    Conlan, Sharon; And Others

    A 14-month pilot of INFO-U, a fully automated telephone information service, assessed the feasibility of the technology in Minnesota Extension Service (MES) county offices to respond to consumer telephone queries. The project was designed to: (1) explore the potential of regional Extension cooperation and resource sharing; (2) increase recognition…

  8. 12 CFR 205.14 - Electronic fund transfer service provider not holding consumer's account.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the debit card; (iv) The service provider transmits to the account-holding institution the information... consumer's account is subject to all requirements of this part if the person: (1) Issues a debit card (or... the periodic statement required by § 205.9(b) if the following conditions are met: (i) The debit card...

  9. Consumer preferences for electronic cigarettes: results from a discrete choice experiment.

    PubMed

    Czoli, Christine D; Goniewicz, Maciej; Islam, Towhidul; Kotnowski, Kathy; Hammond, David

    2016-04-01

    E-cigarettes present a formidable challenge to regulators given their variety and the rapidly evolving nicotine market. The current study sought to examine the influence of e-cigarette product characteristics on consumer perceptions and trial intentions among Canadians. An online discrete choice experiment was conducted with 915 Canadians aged 16 years and older in November 2013. An online commercial panel was used to sample 3 distinct subpopulations: (1) non-smoking youth and young adults (n=279); (2) smoking youth and young adults (n=264) and (3) smoking adults (n=372). Participants completed a series of stated-preference tasks, in which they viewed choice sets with e-cigarette product images that featured different combinations of attributes: flavour, nicotine content, health warnings and price. For each choice set, participants were asked to select one of the products or indicate 'none of the above' with respect to the following outcomes: interest in trying, less harm and usefulness in quitting smoking. The attributes' impact on consumer choice for each outcome was analysed using multinomial logit regression. Health warning was the most important attribute influencing participants' intentions to try e-cigarettes (42%) and perceived efficacy as a quit aid (39%). Both flavour (36%) and health warnings (35%) significantly predicted perceptions of product harm. The findings indicate that consumers make trade-offs with respect to e-cigarette product characteristics, and that these trade-offs vary across different subpopulations. Given that health warnings and flavour were weighted most important by consumers in this study, these may represent good targets for e-cigarette regulatory frameworks. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Security Implications of Electronic Commerce: A Survey of Consumers and Businesses.

    ERIC Educational Resources Information Center

    Furnell, S. M.; Karweni, T.

    1999-01-01

    Examines general requirement for security technologies that provide a basis for trust in the electronic commerce environment. Discusses the results of two surveys that included general Internet users who are potential customers as well as commercial businesses, that considered attitudes to electronic commerce in general and options relating to…

  11. Security Implications of Electronic Commerce: A Survey of Consumers and Businesses.

    ERIC Educational Resources Information Center

    Furnell, S. M.; Karweni, T.

    1999-01-01

    Examines general requirement for security technologies that provide a basis for trust in the electronic commerce environment. Discusses the results of two surveys that included general Internet users who are potential customers as well as commercial businesses, that considered attitudes to electronic commerce in general and options relating to…

  12. Consumer behaviour and environmental education in the field of waste electrical and electronic toys: A Spanish case study

    SciTech Connect

    Pérez-Belis, V.

    2015-02-15

    Highlights: • Consumption/disposal habits of waste electrical and electronic toys. • Environmental education as a key factor to improve WEEE management. • Three environmental education actions to increase the collection of waste toys. - Abstract: This paper reports on a project focused on obtaining the current consumption and disposal habits of electrical and electronic toys from a survey aimed at parents of children of nine pre- and primary schools. In addition, it is also focused on identifying the most effective way of transmitting environmental information to parents and children to promote the collection of electrical and electronic toys at their end-of-life. The study was implemented in a Spanish municipality. With regard to the consumption habits, aspects related to the amount of toys that children receive annually and percentage of those which are electrical and electronic toys have been obtained and classified according to the family size. Results from Chi-squared analysis and Ordinal Logistic Regression show that there is a statistically significance relationship among these variables. Regarding disposal habits, aspects related to the reasons and way for discarding electrical and electronic toys, time that toys are kept at home or the willingness to rent or buy second hand e-toys have been obtained. What really attracts attention is that, apart from consumers who donate the toy to family or social associations, 67.1% of consumers discard them along with other waste fractions in domestic bins, whereas only 32.9% do so at recycling points, as Directive 2012/19/EU requires. To increase this percentage, three environmental education actions (distinguishing from each other by the way used to transmit the environmental information: paper, audiovisual or personal communication) have been designed, applied and evaluated their efficiency according to the amount of waste toys collected.

  13. Consumer behaviour and environmental education in the field of waste electrical and electronic toys: a Spanish case study.

    PubMed

    Pérez-Belis, V; Bovea, M D; Simó, A

    2015-02-01

    This paper reports on a project focused on obtaining the current consumption and disposal habits of electrical and electronic toys from a survey aimed at parents of children of nine pre- and primary schools. In addition, it is also focused on identifying the most effective way of transmitting environmental information to parents and children to promote the collection of electrical and electronic toys at their end-of-life. The study was implemented in a Spanish municipality. With regard to the consumption habits, aspects related to the amount of toys that children receive annually and percentage of those which are electrical and electronic toys have been obtained and classified according to the family size. Results from Chi-squared analysis and Ordinal Logistic Regression show that there is a statistically significance relationship among these variables. Regarding disposal habits, aspects related to the reasons and way for discarding electrical and electronic toys, time that toys are kept at home or the willingness to rent or buy second hand e-toys have been obtained. What really attracts attention is that, apart from consumers who donate the toy to family or social associations, 67.1% of consumers discard them along with other waste fractions in domestic bins, whereas only 32.9% do so at recycling points, as Directive 2012/19/EU requires. To increase this percentage, three environmental education actions (distinguishing from each other by the way used to transmit the environmental information: paper, audiovisual or personal communication) have been designed, applied and evaluated their efficiency according to the amount of waste toys collected. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. 12 CFR 205.14 - Electronic fund transfer service provider not holding consumer's account.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... initiates a transfer to effect a provisional credit in accordance with § 205.11(c)(2)(ii). (iii) If the..., in the appropriate amount and within the applicable time period, in accordance with § 205.11(c)(2)(i... 12 Banks and Banking 2 2012-01-01 2012-01-01 false Electronic fund transfer service provider...

  15. 12 CFR 205.14 - Electronic fund transfer service provider not holding consumer's account.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... initiates a transfer to effect a provisional credit in accordance with § 205.11(c)(2)(ii). (iii) If the..., in the appropriate amount and within the applicable time period, in accordance with § 205.11(c)(2)(i... 12 Banks and Banking 2 2010-01-01 2010-01-01 false Electronic fund transfer service provider...

  16. 12 CFR 205.14 - Electronic fund transfer service provider not holding consumer's account.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... initiates a transfer to effect a provisional credit in accordance with § 205.11(c)(2)(ii). (iii) If the..., in the appropriate amount and within the applicable time period, in accordance with § 205.11(c)(2)(i... 12 Banks and Banking 2 2013-01-01 2013-01-01 false Electronic fund transfer service provider...

  17. 12 CFR 205.14 - Electronic fund transfer service provider not holding consumer's account.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... initiates a transfer to effect a provisional credit in accordance with § 205.11(c)(2)(ii). (iii) If the..., in the appropriate amount and within the applicable time period, in accordance with § 205.11(c)(2)(i... 12 Banks and Banking 2 2011-01-01 2011-01-01 false Electronic fund transfer service provider...

  18. Portable Cooler/Warmers

    NASA Technical Reports Server (NTRS)

    1994-01-01

    Early in the space program, NASA recognized the need to replace bulky coils, compressers, and motors for refrigeration purposes by looking at existing thermoelectric technology. This effort resulted in the development of miniaturized thermoelectric components and packaging to accommodate tight confines of spacecraft. Koolatron's portable electronic refrigerators incorporate this NASA technology. Each of the cooler/warmers employs one or two miniaturized thermoelectric modules. Although each module is only the size of a book of matches, it delivers the cooling power of a 10-pound block of ice. In some models, the cooler can be converted to a warmer. There are no moving parts. The Koolatrons can be plugged into auto cigarette lighters, recreational vehicles, boats or motel outlets.

  19. 78 FR 33393 - Petition Requesting a Ban or Standard on Adult Portable Bed Rails

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-04

    ... COMMISSION Petition Requesting a Ban or Standard on Adult Portable Bed Rails AGENCY: Consumer Product Safety... Safety Act (CPSA) to determine that adult portable bed rails pose an unreasonable risk of injury and... (CPSA) to determine that adult portable bed rails pose an unreasonable risk of injury and...

  20. Portable Presentation And Instruction Unit

    NASA Technical Reports Server (NTRS)

    Christman, L.; Hoang, N.

    1994-01-01

    Proposed electronic display unit reminiscent of kiosk serves as portable, interactive, multimedia information terminal. Used as traveling science exhibit, aid for teaching science in schools, or training and skill-refresher device for space flight crews. Provides interactive video and audio displays, including three-dimensional-appearing video simulations. Speeds learning and improves retention by applying principles of scientific visualization. Also helps previously trained but recently unpracticed personnel relearn special skills and procedures quickly.

  1. Portable Presentation And Instruction Unit

    NASA Technical Reports Server (NTRS)

    Christman, L.; Hoang, N.

    1994-01-01

    Proposed electronic display unit reminiscent of kiosk serves as portable, interactive, multimedia information terminal. Used as traveling science exhibit, aid for teaching science in schools, or training and skill-refresher device for space flight crews. Provides interactive video and audio displays, including three-dimensional-appearing video simulations. Speeds learning and improves retention by applying principles of scientific visualization. Also helps previously trained but recently unpracticed personnel relearn special skills and procedures quickly.

  2. Portable Tandem Mass Spectrometer Analyzer

    DTIC Science & Technology

    1991-07-01

    The planned instrument was to be small enough to be portable in small vehicles and was to be able to use either an atmospheric pressure ion source or a...conventional electron impact/chemical ionization ion source. In order to accomplish these developments an atmospheric pressure ionization source was...developed for a compact, commercially available tandem quadrupole mass spectrometer. This ion source could be readily exchanged with the conventional

  3. A systematic procedure for modeling usability based on product design variables: a case study in audiovisual consumer electronic products.

    PubMed

    Kim, Kwang Jae; Han, Sung H; Yun, Myung Hwan; Kwahk, Jiyoung

    2002-01-01

    A systematic modeling approach to describing, prescribing, and predicting usability of a product has been presented. Given the evaluation results of the usability dimension (UD) and the measurement of the product's design variables, referred to as the human interface elements (HIEs), the approach enables one to systematically assess the relationship between the UD and HIEs. The assessed relationship is called a usability model. Once built, such a usability model can relate, in a quantitative manner, the HIEs directly to the UDs, and thus can serve as an effective aid to designers by evaluating and predicting the usability of an existing or hypothetical product. A usability model for elegance of audiovisual consumer electronic products has been demonstrated.

  4. MEMS (Micro-Electro-Mechanical Systems) for Automotive and Consumer Electronics

    NASA Astrophysics Data System (ADS)

    Marek, Jiri; Gómez, Udo-Martin

    MEMS sensors gained over the last two decades an impressive width of applications: (a) ESP: A car is skidding and stabilizes itself without driver intervention (b) Free-fall detection: A laptop falls to the floor and protects the hard drive by parking the read/write drive head automatically before impact. (c) Airbag: An airbag fires before the driver/occupant involved in an impending automotive crash impacts the steering wheel, thereby significantly reducing physical injury risk. MEMS sensors are sensing the environmental conditions and are giving input to electronic control systems. These crucial MEMS sensors are making system reactions to human needs more intelligent, precise, and at much faster reaction rates than humanly possible. Important prerequisites for the success of sensors are their size, functionality, power consumption, and costs. This technical progress in sensor development is realized by micro-machining. The development of these processes was the breakthrough to industrial mass-production for micro-electro-mechanical systems (MEMS). Besides leading-edge micromechanical processes, innovative and robust ASIC designs, thorough simulations of the electrical and mechanical behaviour, a deep understanding of the interactions (mainly over temperature and lifetime) of the package and the mechanical structures are needed. This was achieved over the last 20 years by intense and successful development activities combined with the experience of volume production of billions of sensors. This chapter gives an overview of current MEMS technology, its applications and the market share. The MEMS processes are described, and the challenges of MEMS, compared to standard IC fabrication, are discussed. The evolution of MEMS requirements is presented, and a short survey of MEMS applications is shown. Concepts of newest inertial sensors for ESP-systems are given with an emphasis on the design concepts of the sensing element and the evaluation circuit for achieving

  5. Quantitation of tetrabromobisphenol-A from dust sampled on consumer electronics by dispersed liquid-liquid microextraction.

    PubMed

    Di Napoli-Davis, Gina; Owens, Janel E

    2013-09-01

    Tetrabromobisphenol-A (TBBPA) is a brominated flame retardant used worldwide. Despite its widespread use, there are few data concerning environmental concentrations of TBBPA. Thus, the objective of this work was to optimize an ultrasound-assisted dispersed liquid-liquid microextraction (DLLME) method to analyze swabbed surfaces of consumer electronics to determine TBBPA concentrations. Upon sample preparation with DLLME, TBBPA was derivatized with acetic anhydride and then analyzed by gas chromatography-mass spectrometry (GC/MS). Using a (13)C12-TBBPA internal standard to improve precision and quantitation, a recovery study was performed. At concentrations of 250-1000 ng/mL, recoveries were 104-106%. Sample preparation with solid phase extraction had comparable recoveries, although overall, improved analyte recovery and precision were achieved with DLLME. In a small survey study, TBBPA concentrations in dust collected from 100 cm(2) areas on electronic surfaces (monitor, microwave, refrigerator, and TV) were determined to range from less than the LOQ to 523 ng/mL.

  6. An investigation of used electronics return flows: a data-driven approach to capture and predict consumers storage and utilization behavior.

    PubMed

    Sabbaghi, Mostafa; Esmaeilian, Behzad; Raihanian Mashhadi, Ardeshir; Behdad, Sara; Cade, Willie

    2015-02-01

    Consumers often have a tendency to store their used, old or un-functional electronics for a period of time before they discard them and return them back to the waste stream. This behavior increases the obsolescence rate of used still-functional products leading to lower profitability that could be resulted out of End-of-Use (EOU) treatments such as reuse, upgrade, and refurbishment. These types of behaviors are influenced by several product and consumer-related factors such as consumers' traits and lifestyles, technology evolution, product design features, product market value, and pro-environmental stimuli. Better understanding of different groups of consumers, their utilization and storage behavior and the connection of these behaviors with product design features helps Original Equipment Manufacturers (OEMs) and recycling and recovery industry to better overcome the challenges resulting from the undesirable storage of used products. This paper aims at providing insightful statistical analysis of Electronic Waste (e-waste) dynamic nature by studying the effects of design characteristics, brand and consumer type on the electronics usage time and end of use time-in-storage. A database consisting of 10,063 Hard Disk Drives (HDD) of used personal computers returned back to a remanufacturing facility located in Chicago, IL, USA during 2011-2013 has been selected as the base for this study. The results show that commercial consumers have stored computers more than household consumers regardless of brand and capacity factors. Moreover, a heterogeneous storage behavior is observed for different brands of HDDs regardless of capacity and consumer type factors. Finally, the storage behavior trends are projected for short-time forecasting and the storage times are precisely predicted by applying machine learning methods. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Portable modular detection system

    DOEpatents

    Brennan, James S.; Singh, Anup; Throckmorton, Daniel J.; Stamps, James F.

    2009-10-13

    Disclosed herein are portable and modular detection devices and systems for detecting electromagnetic radiation, such as fluorescence, from an analyte which comprises at least one optical element removably attached to at least one alignment rail. Also disclosed are modular detection devices and systems having an integrated lock-in amplifier and spatial filter and assay methods using the portable and modular detection devices.

  8. Portable seat lift

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce (Inventor)

    1994-01-01

    A portable seat lift that can help individuals either (1) lower themselves to a sitting position or (2) raise themselves to a standing position is presented. The portable seat lift consists of a seat mounted on a base with two levers, which are powered by a drive unit.

  9. Software Engineering for Portability.

    ERIC Educational Resources Information Center

    Stanchev, Ivan

    1990-01-01

    Discussion of the portability of educational software focuses on the software design and development process. Topics discussed include levels of portability; the user-computer dialog; software engineering principles; design techniques for student performance records; techniques of courseware programing; and suggestions for further research and…

  10. Portable raman explosives detection

    SciTech Connect

    Moore, David Steven; Scharff, Robert J

    2008-01-01

    Recent advances in portable Raman instruments have dramatically increased their application to emergency response and forensics, as well as homeland defense. This paper reviews the relevant attributes and disadvantages of portable Raman spectroscopy, both essentially and instrumentally, to the task of explosives detection in the field.

  11. Portable Multiplex Pathogen Detector

    SciTech Connect

    Visuri, S; McBride, M T; Matthews, D; Rao, R

    2002-07-15

    Tumor marker concentrations in serum provide useful information regarding clinical stage and prognosis of cancer and can thus be used for presymptomatic diagnostic purposes. Currently, detection and identification of soluble analytes in biological fluids is conducted by methods including bioassays, ELISA, PCR, DNA chip or strip tests. While these technologies are generally sensitive and specific, they are time consuming, labor intensive and cannot be multiplexed. Our goal is to develop a simple, point-of-care, portable, liquid array-based immunoassay device capable of simultaneous detection of a variety of cancer markers. Here we describe the development of assays for the detection of Serum Prostate Specific Antigen, and Ovalbumin from a single sample. The multiplexed immunoassays utilize polystyrene microbeads. The beads are imbedded with precise ratios of red and orange fluorescent dyes yielding an array of 100 beads, each with a unique spectral address (Figure 1). Each bead can be coated with capture antibodies specific for a given antigen. After antigen capture, secondary antibodies sandwich the bound antigen and are indirectly labeled by the fluorescent reporter phycoerythrin (PE). Each optically encoded and fluorescently-labeled microbead is then individually interrogated. A red laser excites the dye molecules imbedded inside the bead and classifies the bead to its unique bead set, and a green laser quantifies the assay at the bead surface. This technology has been proven to be comparable to the ELISA in terms of sensitivity and specificity. We also describe the laser-based instrumentation used to acquire fluorescent bead images Following the assay, droplets of bead suspension containing a mixture of bead classes were deposited onto filters held in place by a disposable plexiglass device and the resultant arrays viewed under the fluorescent imaging setup. Using the appropriate filter sets to extract the necessary red, orange and green fluorescence from the

  12. An Effective Electrical Throughput from PANI Supplement ZnS Nanorods and PDMS-Based Flexible Piezoelectric Nanogenerator for Power up Portable Electronic Devices: An Alternative of MWCNT Filler.

    PubMed

    Sultana, Ayesha; Alam, Md Mehebub; Garain, Samiran; Sinha, Tridib Kumar; Middya, Tapas Ranjan; Mandal, Dipankar

    2015-09-02

    We demonstrate the requirement of electrical poling can be avoided in flexible piezoelectric nanogenerators (FPNGs) made of low-temperature hydrothermally grown wurtzite zinc sulfide nanorods (ZnS-NRs) blended with polydimethylsiloxane (PDMS). It has been found that conductive fillers, such as polyaniline (PANI) and multiwall carbon nanotubes (MWCNTs), can subsequently improve the overall performance of FPNG. A large electrical throughput (open circuit voltage ∼35 V with power density ∼2.43 μW/cm(3)) from PANI supplement added nanogenerator (PZP-FPNG) indicates that it is an effective means to replace the MWCNTs filler. The time constant (τ) estimated from the transient response of the capacitor charging curves signifying that the FPNGs are very much capable to charge the capacitors in very short time span (e.g., 3 V is accomplished in 50 s) and thus expected to be perfectly suitable in portable, wearable and flexible electronics devices. We demonstrate that FPNG can instantly lit up several commercial Light Emitting Diodes (LEDs) (15 red, 25 green, and 55 blue, individually) and power up several portable electronic gadgets, for example, wrist watch, calculator, and LCD screen. Thus, a realization of potential use of PANI in low-temperature-synthesized ZnS-NRs comprising piezoelectric based nanogenerator fabrication is experimentally verified so as to acquire a potential impact in sustainable energy applications. Beside this, wireless piezoelectric signal detection possibility is also worked out where a concept of self-powered smart sensor is introduced.

  13. An investigation of used electronics return flows: A data-driven approach to capture and predict consumers storage and utilization behavior

    SciTech Connect

    Sabbaghi, Mostafa; Esmaeilian, Behzad; Raihanian Mashhadi, Ardeshir; Behdad, Sara; Cade, Willie

    2015-02-15

    Highlights: • We analyzed a data set of HDDs returned back to an e-waste collection site. • We studied factors that affect the storage behavior. • Consumer type, brand and size are among factors which affect the storage behavior. • Commercial consumers have stored computers more than household consumers. • Machine learning models were used to predict the storage behavior. - Abstract: Consumers often have a tendency to store their used, old or un-functional electronics for a period of time before they discard them and return them back to the waste stream. This behavior increases the obsolescence rate of used still-functional products leading to lower profitability that could be resulted out of End-of-Use (EOU) treatments such as reuse, upgrade, and refurbishment. These types of behaviors are influenced by several product and consumer-related factors such as consumers’ traits and lifestyles, technology evolution, product design features, product market value, and pro-environmental stimuli. Better understanding of different groups of consumers, their utilization and storage behavior and the connection of these behaviors with product design features helps Original Equipment Manufacturers (OEMs) and recycling and recovery industry to better overcome the challenges resulting from the undesirable storage of used products. This paper aims at providing insightful statistical analysis of Electronic Waste (e-waste) dynamic nature by studying the effects of design characteristics, brand and consumer type on the electronics usage time and end of use time-in-storage. A database consisting of 10,063 Hard Disk Drives (HDD) of used personal computers returned back to a remanufacturing facility located in Chicago, IL, USA during 2011–2013 has been selected as the base for this study. The results show that commercial consumers have stored computers more than household consumers regardless of brand and capacity factors. Moreover, a heterogeneous storage behavior is

  14. Human portable preconcentrator system

    DOEpatents

    Linker, Kevin L.; Bouchier, Francis A.; Hannum, David W.; Rhykerd, Jr., Charles L.

    2003-01-01

    A preconcentrator system and apparatus suited to human portable use wherein sample potentially containing a target chemical substance is drawn into a chamber and through a pervious screen. The screen is adapted to capture target chemicals and then, upon heating, to release those chemicals into the chamber. Chemicals captured and then released in this fashion are then carried to a portable chemical detection device such as a portable ion mobility spectrometer. In the preferred embodiment, the means for drawing sample into the chamber comprises a reversible fan which, when operated in reverse direction, creates a backpressure that facilitates evolution of captured target chemicals into the chamber when the screen is heated.

  15. Inexpensive portable drug detector

    NASA Technical Reports Server (NTRS)

    Dimeff, J.; Heimbuch, A. H.; Parker, J. A.

    1977-01-01

    Inexpensive, easy-to-use, self-scanning, self-calibrating, portable unit automatically graphs fluorescence spectrum of drug sample. Device also measures rate of movement through chromatographic column for forensic and medical testing.

  16. Inexpensive portable drug detector

    NASA Technical Reports Server (NTRS)

    Dimeff, J.; Heimbuch, A. H.; Parker, J. A.

    1977-01-01

    Inexpensive, easy-to-use, self-scanning, self-calibrating, portable unit automatically graphs fluorescence spectrum of drug sample. Device also measures rate of movement through chromatographic column for forensic and medical testing.

  17. Portable Microfiche Readers.

    ERIC Educational Resources Information Center

    Zybura, Edward L.

    1980-01-01

    Provides an introduction to use of three types of portable microfiche readers: hand-held readers, briefcase readers, and self-contained mobile readers. Features described include image quality, method of operation, product history, and optimal environments for utilization. (SW)

  18. Evaluation of Energy Efficiency Improvements to Portable Classrooms in Florida.

    ERIC Educational Resources Information Center

    Callahan, Michael P.; Parker, Danny S.; Sherwin, John R.; Anello, Michael T.

    Findings are presented from a 2-year experiment exploring ways to reduce energy costs and improve the learning environment in Florida's 25,000 portable classrooms. Improvements were made in two highly instrumented portable classrooms in the following areas: installation of a T8 lighting system with electronic ballasts; a high efficiency heat pump…

  19. Portable Dental System

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Portable dental system provides dental care in isolated communities. System includes a patient's chair and a dentist's stool, an X-ray machine and a power unit, all of which fold into compact packages. A large yellow "pumpkin" is a collapsible compressed air tank. Portable system has been used successfully in South America in out of the way communities with this back-packable system, and in American nursing homes. This product is no longer manufactured.

  20. Portable treatment systems study

    SciTech Connect

    Sherick, M.J.; Schwinkendorf, W.E.; Bechtold, T.E.; Cole, L.T.

    1997-03-01

    In developing their Site Treatment Plans (STPs), many of the Department of Energy installations identified some form of portable treatment, to facilitate compliant disposition of select mixed low-level wastestreams. The Environmental Management Office of Science and Technology requested that a systems study be performed to better define the potential role of portable treatment with respect to mixed low-level waste, highlight obstacles to implementation, and identify opportunities for future research and development emphasis. The study was performed by first establishing a representative set of mixed waste, then formulating portable treatment system concepts to meet the required processing needs for these wastes. The portable systems that were conceptualized were evaluated and compared to a fixed centralized treatment alternative. The system evaluations include a life-cycle cost analysis and an assessment of regulatory, institutional, and technical issues associated with the potential use of portable systems. The results of this study show that when all costs are included, there are no significant cost differences between portable systems and fixed systems. However, it is also emphasized that many uncertainties exist that could impact the cost of implementing portable treatment systems. Portable treatment could be made more attractive through private sector implementation, although there is little economic incentive for a commercial vendor to develop small, specialized treatment capabilities with limited applicability. Alternatively, there may also be valid reasons why fixed units cannot be used for some problematic wastestreams. In any event, there are some site-specific problems that still need to be addressed, and there may be some opportunity for research and development to make a positive impact in these areas.

  1. Portable Power And Digital-Communication Units

    NASA Technical Reports Server (NTRS)

    Levin, Richard R.; Henry, Paul K.; Rosenberg, Leigh S.

    1992-01-01

    Conceptual network of electronic-equipment modules provides electrical power and digital radio communications at multiple sites not served by cables. System includes central communication unit and portable units powered by solar photovoltaic arrays. Useful to serve equipment that must be set up quickly at remote sites or buildings that cannot be modified to provide cable connections.

  2. Japan's electronic packaging technologies

    NASA Technical Reports Server (NTRS)

    Tummala, Rao R.; Pecht, Michael

    1995-01-01

    The JTEC panel found Japan to have significant leadership over the United States in the strategic area of electronic packaging. Many technologies and products once considered the 'heart and soul' of U.S. industry have been lost over the past decades to Japan and other Asian countries. The loss of consumer electronics technologies and products is the most notable of these losses, because electronics is the United States' largest employment sector and is critical for growth businesses in consumer products, computers, automobiles, aerospace, and telecommunications. In the past there was a distinction between consumer and industrial product technologies. While Japan concentrated on the consumer market, the United States dominated the industrial sector. No such distinction is anticipated in the future; the consumer-oriented technologies Japan has dominated are expected to characterize both domains. The future of U.S. competitiveness will, therefore, depend on the ability of the United States to rebuild its technological capabilities in the area of portable electronic packaging.

  3. Japan's electronic packaging technologies

    NASA Astrophysics Data System (ADS)

    Tummala, Rao R.; Pecht, Michael

    1995-02-01

    The JTEC panel found Japan to have significant leadership over the United States in the strategic area of electronic packaging. Many technologies and products once considered the 'heart and soul' of U.S. industry have been lost over the past decades to Japan and other Asian countries. The loss of consumer electronics technologies and products is the most notable of these losses, because electronics is the United States' largest employment sector and is critical for growth businesses in consumer products, computers, automobiles, aerospace, and telecommunications. In the past there was a distinction between consumer and industrial product technologies. While Japan concentrated on the consumer market, the United States dominated the industrial sector. No such distinction is anticipated in the future; the consumer-oriented technologies Japan has dominated are expected to characterize both domains. The future of U.S. competitiveness will, therefore, depend on the ability of the United States to rebuild its technological capabilities in the area of portable electronic packaging.

  4. Japan's electronic packaging technologies

    NASA Technical Reports Server (NTRS)

    Tummala, Rao R.; Pecht, Michael

    1995-01-01

    The JTEC panel found Japan to have significant leadership over the United States in the strategic area of electronic packaging. Many technologies and products once considered the 'heart and soul' of U.S. industry have been lost over the past decades to Japan and other Asian countries. The loss of consumer electronics technologies and products is the most notable of these losses, because electronics is the United States' largest employment sector and is critical for growth businesses in consumer products, computers, automobiles, aerospace, and telecommunications. In the past there was a distinction between consumer and industrial product technologies. While Japan concentrated on the consumer market, the United States dominated the industrial sector. No such distinction is anticipated in the future; the consumer-oriented technologies Japan has dominated are expected to characterize both domains. The future of U.S. competitiveness will, therefore, depend on the ability of the United States to rebuild its technological capabilities in the area of portable electronic packaging.

  5. A randomised controlled trial of a consumer-focused e-health strategy for cardiovascular risk management in primary care: the Consumer Navigation of Electronic Cardiovascular Tools (CONNECT) study protocol.

    PubMed

    Redfern, Julie; Usherwood, T; Harris, M F; Rodgers, A; Hayman, N; Panaretto, K; Chow, C; Lau, A Y S; Neubeck, L; Coorey, G; Hersch, F; Heeley, E; Patel, A; Jan, S; Zwar, N; Peiris, D

    2014-01-31

    Fewer than half of all people at highest risk of a cardiovascular event are receiving and adhering to best practice recommendations to lower their risk. In this project, we examine the role of an e-health-assisted consumer-focused strategy as a means of overcoming these gaps between evidence and practice. Consumer Navigation of Electronic Cardiovascular Tools (CONNECT) aims to test whether a consumer-focused e-health strategy provided to Aboriginal and Torres Strait Islander and non-indigenous adults, recruited through primary care, at moderate-to-high risk of a cardiovascular disease event will improve risk factor control when compared with usual care. Randomised controlled trial of 2000 participants with an average of 18 months of follow-up to evaluate the effectiveness of an integrated consumer-directed e-health portal on cardiovascular risk compared with usual care in patients with cardiovascular disease or who are at moderate-to-high cardiovascular disease risk. The trial will be augmented by formal economic and process evaluations to assess acceptability, equity and cost-effectiveness of the intervention. The intervention group will participate in a consumer-directed e-health strategy for cardiovascular risk management. The programme is electronically integrated with the primary care provider's software and will include interactive smart phone and Internet platforms. The primary outcome is a composite endpoint of the proportion of people meeting the Australian guideline-recommended blood pressure (BP) and cholesterol targets. Secondary outcomes include change in mean BP and fasting cholesterol levels, proportion meeting BP and cholesterol targets separately, self-efficacy, health literacy, self-reported point prevalence abstinence in smoking, body mass index and waist circumference, self-reported physical activity and self-reported medication adherence. Primary ethics approval was received from the University of Sydney Human Research Ethics Committee and the

  6. A randomised controlled trial of a consumer-focused e-health strategy for cardiovascular risk management in primary care: the Consumer Navigation of Electronic Cardiovascular Tools (CONNECT) study protocol

    PubMed Central

    Redfern, Julie; Usherwood, T; Harris, M F; Rodgers, A; Hayman, N; Panaretto, K; Chow, C; Lau, A Y S; Neubeck, L; Coorey, G; Hersch, F; Heeley, E; Patel, A; Jan, S; Zwar, N; Peiris, D

    2014-01-01

    Introduction Fewer than half of all people at highest risk of a cardiovascular event are receiving and adhering to best practice recommendations to lower their risk. In this project, we examine the role of an e-health-assisted consumer-focused strategy as a means of overcoming these gaps between evidence and practice. Consumer Navigation of Electronic Cardiovascular Tools (CONNECT) aims to test whether a consumer-focused e-health strategy provided to Aboriginal and Torres Strait Islander and non-indigenous adults, recruited through primary care, at moderate-to-high risk of a cardiovascular disease event will improve risk factor control when compared with usual care. Methods and analysis Randomised controlled trial of 2000 participants with an average of 18 months of follow-up to evaluate the effectiveness of an integrated consumer-directed e-health portal on cardiovascular risk compared with usual care in patients with cardiovascular disease or who are at moderate-to-high cardiovascular disease risk. The trial will be augmented by formal economic and process evaluations to assess acceptability, equity and cost-effectiveness of the intervention. The intervention group will participate in a consumer-directed e-health strategy for cardiovascular risk management. The programme is electronically integrated with the primary care provider's software and will include interactive smart phone and Internet platforms. The primary outcome is a composite endpoint of the proportion of people meeting the Australian guideline-recommended blood pressure (BP) and cholesterol targets. Secondary outcomes include change in mean BP and fasting cholesterol levels, proportion meeting BP and cholesterol targets separately, self-efficacy, health literacy, self-reported point prevalence abstinence in smoking, body mass index and waist circumference, self-reported physical activity and self-reported medication adherence. Ethics and dissemination Primary ethics approval was received from the

  7. Highly Selective Screening of Estrogenic Compounds in Consumer-Electronics Plastics by Liquid Chromatography in Parallel Combined with Nanofractionation-Bioactivity Detection and Mass Spectrometry.

    PubMed

    Jonker, Willem; Ballesteros-Gómez, Ana; Hamers, Timo; Somsen, Govert W; Lamoree, Marja H; Kool, Jeroen

    2016-11-15

    The chemical safety of consumer products is an issue of emerging concern. Plastics are widely used, e.g. as casings of consumer electronics (TVs, computers, routers, etc.), which are present in houses and offices in continuously increasing numbers. In this study, we investigate the estrogenic activity of components of plastics coming from electronics' casings. A recently developed fractionation platform for effect-directed analysis (EDA) was used. This platform combines reversed-phase liquid chromatography in parallel with bioassay detection via nanofractionation and with online high-resolution time-of-flight mass spectrometry (TOFMS) for the identification of bioactives. Four out of eight of the analyzed plastics samples showed the presence of estrogenic compounds. Based on the MS results these were assigned to bisphenol A (BPA), 2,4-di-tert-butylphenol, and a possible bisphenol A analog. All samples contained flame retardants, but these did not show any estrogenicity. The observed BPA, however, could be an impurity of tetrabromo-BPA (TBBPA) or TBBPA-based flame retardants. Due to the plausible migration of additives from plastics into the environment, plastics from consumer electronics likely constitute a source of estrogenic compound contamination in the indoor environment.

  8. Portable biochip scanner device

    DOEpatents

    Perov, Alexander; Sharonov, Alexei; Mirzabekov, Andrei D.

    2002-01-01

    A portable biochip scanner device used to detect and acquire fluorescence signal data from biological microchips (biochips) is provided. The portable biochip scanner device employs a laser for emitting an excitation beam. An optical fiber delivers the laser beam to a portable biochip scanner. A lens collimates the laser beam, the collimated laser beam is deflected by a dichroic mirror and focused by an objective lens onto a biochip. The fluorescence light from the biochip is collected and collimated by the objective lens. The fluorescence light is delivered to a photomultiplier tube (PMT) via an emission filter and a focusing lens. The focusing lens focuses the fluorescence light into a pinhole. A signal output of the PMT is processed and displayed.

  9. Deflectometry using portable devices

    NASA Astrophysics Data System (ADS)

    Butel, Guillaume P.; Smith, Greg A.; Burge, James H.

    2015-02-01

    Deflectometry is a powerful metrology technique that uses off-the-shelf equipment to achieve nanometer-level accuracy surface measurements. However, there is no portable device to quickly measure eyeglasses, lenses, or mirrors. We present an entirely portable new deflectometry technique that runs on any Android™ smartphone with a front-facing camera. Our technique overcomes some specific issues of portable devices like screen nonlinearity and automatic gain control. We demonstrate our application by measuring an amateur telescope mirror and simulating a measurement of the faulty Hubble Space Telescope primary mirror. Our technique can, in less than 1 min, measure surface errors with accuracy up to 50 nm RMS, simply using a smartphone.

  10. Human portable preconcentrator system

    DOEpatents

    Linker, Kevin L.; Brusseau, Charles A.; Hannum, David W.; Puissant, James G.; Varley, Nathan R.

    2003-08-12

    A preconcentrator system and apparatus suited to human portable use wherein sample potentially containing a target chemical substance is drawn into a chamber and through a pervious screen. The screen is adapted to capture target chemicals and then, upon heating, to release those chemicals into the chamber. Chemicals captured and then released in this fashion are then carried to a portable chemical detection device such as a portable ion mobility spectrometer. In the preferred embodiment, the means for drawing sample into the chamber comprises a reversible fan which, when operated in reverse direction, creates a backpressure that facilitates evolution of captured target chemicals into the chamber when the screen is heated. The screen can be positioned directly in front of the detector prior to heating to improve detection capability.

  11. [Portable peristaltic perfusion pumps].

    PubMed

    Magallón Pedrera, I; Soto Torres, I

    1999-11-01

    Portable peristaltic perfusion pumps allow one to administer pharmaceuticals in hospitals as well as in primary health care centers and furthermore these pumps present multiple advantages for patients and their families since they make it possible to carry out treatment in a patient's home while at the same time lowering the costs involved. The authors analyze the most out standing aspects of portable peristaltic perfusion pumps along with their characteristics, installation, programming, and how to turn them on; in addition, the authors list the maintenance care which these pumps require.

  12. Note: Portable rare-earth element analyzer using pyroelectric crystal

    SciTech Connect

    Imashuku, Susumu Fuyuno, Naoto; Hanasaki, Kohei; Kawai, Jun

    2013-12-15

    We report a portable rare-earth element analyzer with a palm-top size chamber including the electron source of a pyroelectric crystal and the sample stage utilizing cathodoluminescence (CL) phenomenon. The portable rare-earth element analyzer utilizing CL phenomenon is the smallest reported so far. The portable rare-earth element analyzer detected the rare-earth elements Dy, Tb, Er, and Sm of ppm order in zircon, which were not detected by scanning electron microscopy-energy dispersive X-ray spectroscopy analysis. We also performed an elemental mapping of rare-earth elements by capturing a CL image using CCD camera.

  13. High-performance green flexible electronics based on biodegradable cellulose nanofibril paper.

    PubMed

    Jung, Yei Hwan; Chang, Tzu-Hsuan; Zhang, Huilong; Yao, Chunhua; Zheng, Qifeng; Yang, Vina W; Mi, Hongyi; Kim, Munho; Cho, Sang June; Park, Dong-Wook; Jiang, Hao; Lee, Juhwan; Qiu, Yijie; Zhou, Weidong; Cai, Zhiyong; Gong, Shaoqin; Ma, Zhenqiang

    2015-05-26

    Today's consumer electronics, such as cell phones, tablets and other portable electronic devices, are typically made of non-renewable, non-biodegradable, and sometimes potentially toxic (for example, gallium arsenide) materials. These consumer electronics are frequently upgraded or discarded, leading to serious environmental contamination. Thus, electronic systems consisting of renewable and biodegradable materials and minimal amount of potentially toxic materials are desirable. Here we report high-performance flexible microwave and digital electronics that consume the smallest amount of potentially toxic materials on biobased, biodegradable and flexible cellulose nanofibril papers. Furthermore, we demonstrate gallium arsenide microwave devices, the consumer wireless workhorse, in a transferrable thin-film form. Successful fabrication of key electrical components on the flexible cellulose nanofibril paper with comparable performance to their rigid counterparts and clear demonstration of fungal biodegradation of the cellulose-nanofibril-based electronics suggest that it is feasible to fabricate high-performance flexible electronics using ecofriendly materials.

  14. High-performance green flexible electronics based on biodegradable cellulose nanofibril paper

    NASA Astrophysics Data System (ADS)

    Jung, Yei Hwan; Chang, Tzu-Hsuan; Zhang, Huilong; Yao, Chunhua; Zheng, Qifeng; Yang, Vina W.; Mi, Hongyi; Kim, Munho; Cho, Sang June; Park, Dong-Wook; Jiang, Hao; Lee, Juhwan; Qiu, Yijie; Zhou, Weidong; Cai, Zhiyong; Gong, Shaoqin; Ma, Zhenqiang

    2015-05-01

    Today's consumer electronics, such as cell phones, tablets and other portable electronic devices, are typically made of non-renewable, non-biodegradable, and sometimes potentially toxic (for example, gallium arsenide) materials. These consumer electronics are frequently upgraded or discarded, leading to serious environmental contamination. Thus, electronic systems consisting of renewable and biodegradable materials and minimal amount of potentially toxic materials are desirable. Here we report high-performance flexible microwave and digital electronics that consume the smallest amount of potentially toxic materials on biobased, biodegradable and flexible cellulose nanofibril papers. Furthermore, we demonstrate gallium arsenide microwave devices, the consumer wireless workhorse, in a transferrable thin-film form. Successful fabrication of key electrical components on the flexible cellulose nanofibril paper with comparable performance to their rigid counterparts and clear demonstration of fungal biodegradation of the cellulose-nanofibril-based electronics suggest that it is feasible to fabricate high-performance flexible electronics using ecofriendly materials.

  15. High-performance green flexible electronics based on biodegradable cellulose nanofibril paper

    PubMed Central

    Jung, Yei Hwan; Chang, Tzu-Hsuan; Zhang, Huilong; Yao, Chunhua; Zheng, Qifeng; Yang, Vina W.; Mi, Hongyi; Kim, Munho; Cho, Sang June; Park, Dong-Wook; Jiang, Hao; Lee, Juhwan; Qiu, Yijie; Zhou, Weidong; Cai, Zhiyong; Gong, Shaoqin; Ma, Zhenqiang

    2015-01-01

    Today's consumer electronics, such as cell phones, tablets and other portable electronic devices, are typically made of non-renewable, non-biodegradable, and sometimes potentially toxic (for example, gallium arsenide) materials. These consumer electronics are frequently upgraded or discarded, leading to serious environmental contamination. Thus, electronic systems consisting of renewable and biodegradable materials and minimal amount of potentially toxic materials are desirable. Here we report high-performance flexible microwave and digital electronics that consume the smallest amount of potentially toxic materials on biobased, biodegradable and flexible cellulose nanofibril papers. Furthermore, we demonstrate gallium arsenide microwave devices, the consumer wireless workhorse, in a transferrable thin-film form. Successful fabrication of key electrical components on the flexible cellulose nanofibril paper with comparable performance to their rigid counterparts and clear demonstration of fungal biodegradation of the cellulose-nanofibril-based electronics suggest that it is feasible to fabricate high-performance flexible electronics using ecofriendly materials. PMID:26006731

  16. Fixed Facts about Portable Classrooms.

    ERIC Educational Resources Information Center

    Sturgeon, Julie

    1998-01-01

    Discusses the easing of overcrowded schools through the use of portable classrooms and provides an example from Elk Grove Unified School District (California) which has opened entire elementary schools using only portables. Fifteen tips for installing relocatables are highlighted. (GR)

  17. Fixed Facts about Portable Classrooms.

    ERIC Educational Resources Information Center

    Sturgeon, Julie

    1998-01-01

    Discusses the easing of overcrowded schools through the use of portable classrooms and provides an example from Elk Grove Unified School District (California) which has opened entire elementary schools using only portables. Fifteen tips for installing relocatables are highlighted. (GR)

  18. An analysis of deaths in portable cribs and playpens: what can be learned?

    PubMed

    Jackson, Allison; Moon, Rachel Y

    2008-04-01

    To assess the risk of using portable cribs and playpens as sleep surfaces for infants, data from playpen/portable crib deaths occurring between January 1, 1999, and February 4, 2004, that were reported to the Consumer Product Safety Commission were retrospectively reviewed. Twenty-one playpen/portable crib deaths were identified. Two-thirds of the deaths were in infants. Asphyxia, positional asphyxia, and suffocation were the leading causes of death. Several deaths were the consequence of risks unique to playpens and portable cribs: playpen collapse, modifications to the playpen, and improper assembly. The data demonstrate some unique risks posed by playpens/portable cribs, including risks from improper assembly and setup. Programs recommending and using playpens/portable cribs as routine infant sleep surfaces must be aware of the need for additional guidance regarding use of playpens/portable cribs.

  19. A portable neutron coincidence counter

    SciTech Connect

    Peurrung, A.J.; Bowyer, S.M.; Craig, R.A.; Dudder, G.B.; Knopf, M.A.; Panisko, M.E.; Reeder, P.L.; Stromswold, D.C.; Sunberg, D.S.

    1996-11-01

    Pacific Northwest National Laboratory has designed and constructed a prototype portable neutron coincidence counter intended for use in a variety of applications, such as the verification and inspection of weapons components, safety measurements for novel and challenging situations, portable portal deployment to prevent the transportation of fissile materials, uranium enrichment measurements in hard-to-reach locations, waste assays for objects that cannot be measured by existing measurement systems, and decontamination and decommissioning. The counting system weighs less than 40 kg and is composed of parts each weighing no more than 5 kg. In addition, the counter`s design is sufficiently flexible to allow rapid, reliable assembly around containers of nearly arbitrary size and shape. The counter is able to discern the presence of 1 kg of weapons-grade plutonium within an ALR-8 (30-gal drum) in roughly 100 seconds and 10 g in roughly 1000 seconds. The counter`s electronics are also designed for maximum adaptability, allowing operation under a wide variety of circumstances, including exposure to gamma-ray fields of 1 R/h. This report provides a detailed review of the design and construction process. Finally, preliminary experimental measurements that confirm the performance capabilities of this counter are discussed. 6 refs., 18 figs., 3 tabs.

  20. Portable Aerosol Contaminant Extractor

    DOEpatents

    Carlson, Duane C.; DeGange, John J.; Cable-Dunlap, Paula

    2005-11-15

    A compact, portable, aerosol contaminant extractor having ionization and collection sections through which ambient air may be drawn at a nominal rate so that aerosol particles ionized in the ionization section may be collected on charged plate in the collection section, the charged plate being readily removed for analyses of the particles collected thereon.

  1. Portable Lifting Seat

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce

    1993-01-01

    Portable lifting machine assists user in rising from seated position to standing position, or in sitting down. Small and light enough to be carried like briefcase. Used on variety of chairs and benches. Upholstered aluminum box houses mechanism of lifting seat. Springs on outer shaft-and-arm subassembly counterbalance part of user's weight to assist motor.

  2. Portable Suction Lysimeter

    DOEpatents

    Hubbell, Joel M.; Sisson, James B.

    2004-07-13

    A portable lysimeter including a collection vessel having an inflatable bladder and a semi-permeable member assembly at least partially movable in response to inflation of the bladder, a sample conduit in fluid communication with the semi-permeable member and a reservoir in fluid communication with the sample conduit.

  3. Portable COHB Analyzer.

    DTIC Science & Technology

    A portable spectrophotometric apparatus and method therefore for measuring the percentage of carboxyhemoglobin ( COHb ) in blood. The apparatus...comprises a spectrophotometer and wavelength selection filters for testing a reference sample having a hemolizing agent and sodium hyposulfite and a treated...blood sample with the hemolizing agent and sodium hyposulfite and providing a two component COHb -Hb system for determining relative absorbance values

  4. Portable Weld Tester.

    ERIC Educational Resources Information Center

    Eckert, Douglas

    This training manual, which was developed for employees of an automotive plant, is designed to teach trainees to operate a portable weld tester (Miyachi MM-315). In chapter 1, the weld tester's components are illustrated and described, and the procedure for charging its batteries is explained. Chapter 2 illustrates the weld tester's parts,…

  5. Portable Weld Tester.

    ERIC Educational Resources Information Center

    Eckert, Douglas

    This training manual, which was developed for employees of an automotive plant, is designed to teach trainees to operate a portable weld tester (Miyachi MM-315). In chapter 1, the weld tester's components are illustrated and described, and the procedure for charging its batteries is explained. Chapter 2 illustrates the weld tester's parts,…

  6. Portable Breathing Assembly

    NASA Image and Video Library

    2017-06-12

    In the Space Station Processing Facility at NASA's Kennedy Space Center in Florida, Jacobs Test and Operations Support Contract, or TOSC, technicians fill portable breathing apparatuses, or PBAS. The PBAs are to be use on board the International Space Staton to provide astronauts with breathable air in the event of a fire or other emergency situation.

  7. Portable Chamfering Tool

    NASA Technical Reports Server (NTRS)

    Berson, Leo A.

    1987-01-01

    Portable machine tool precisely cuts chamfer on valve seat. With tool, delicate machining operation done without removing part to machine shop. Taken to part and used wherever pressurized air and electric power available. Plug and bushing nest in bore chamfered. They guide steady cutter rod as it cuts 15 degrees chamfer on top edge of bore.

  8. Portable Lifting Seat

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce

    1993-01-01

    Portable lifting machine assists user in rising from seated position to standing position, or in sitting down. Small and light enough to be carried like briefcase. Used on variety of chairs and benches. Upholstered aluminum box houses mechanism of lifting seat. Springs on outer shaft-and-arm subassembly counterbalance part of user's weight to assist motor.

  9. Portable headset microphone checker

    NASA Technical Reports Server (NTRS)

    Davenport, J.; Foster, J. A.; Langley, W. R.

    1975-01-01

    Simple and reliable test system gives go/no-go indication of output level of headset microphones. Portable system has its own internal battery power supply and can be used in field or in laboratory with wide variety of headset types.

  10. PORTABLE SOURCE OF RADIOACTIVITY

    DOEpatents

    Goertz, R.C.; Ferguson, K.R.; Rylander, E.W.; Safranski, L.M.

    1959-06-16

    A portable source for radiogiaphy or radiotherapy is described. It consists of a Tl/sup 170/ or Co/sup 60/ source mounted in a rotatable tungsten alloy plug. The plug rotates within a brass body to positions of safety or exposure. Provision is made for reloading and carrying the device safely. (T.R.H.)

  11. Portable oven air circulator

    DOEpatents

    Jorgensen, Jorgen A.; Nygren, Donald W.

    1983-01-01

    A portable air circulating apparatus for use in cooking ovens which is used to create air currents in the oven which transfer heat to cooking foodstuffs to promote more rapid and more uniform cooking or baking, the apparatus including a motor, fan blade and housing of metallic materials selected from a class of heat resistant materials.

  12. Portable Breathing Assembly

    NASA Image and Video Library

    2017-06-12

    In the Space Station Processing Facility at NASA's Kennedy Space Center in Florida, Jacobs Test and Operations Support Contract, or TOSC, technician Rod Ostgrard helps fill portable breathing apparatuses, or PBAS. The PBAs are to be use on board the International Space Staton to provide astronauts with breathable air in the event of a fire or other emergency situation.

  13. Portable Breathing Assembly

    NASA Image and Video Library

    2017-06-12

    In the Space Station Processing Facility at NASA's Kennedy Space Center in Florida, Jacobs Test and Operations Support Contract, or TOSC, technician John Thompson helps fill portable breathing apparatuses, or PBAS. The PBAs are to be use on board the International Space Staton to provide astronauts with breathable air in the event of a fire or other emergency situation.

  14. Portable Chamfering Tool

    NASA Technical Reports Server (NTRS)

    Berson, Leo A.

    1987-01-01

    Portable machine tool precisely cuts chamfer on valve seat. With tool, delicate machining operation done without removing part to machine shop. Taken to part and used wherever pressurized air and electric power available. Plug and bushing nest in bore chamfered. They guide steady cutter rod as it cuts 15 degrees chamfer on top edge of bore.

  15. 300 WATT PORTABLE THERMOELECTRIC GENERATOR.

    DTIC Science & Technology

    THERMOELECTRICITY, POWER SUPPLIES), (* GENERATORS , THERMOELECTRICITY), (*ELECTRIC POWER PRODUCTION, THERMOELECTRICITY), PORTABLE EQUIPMENT, THERMOCOUPLES, ENERGY CONVERSION, HEAT EXCHANGERS, WIRING DIAGRAMS

  16. The Epidemiology of Emergency Department-Treated Burn Injuries Associated with Portable Heaters in the United States, 2003-2013.

    PubMed

    Brooks, Raina D; McGwin, Gerald

    The purpose of this study is to examine the epidemiology of portable space heater-related burn injuries among an emergency department nationally representative population of the United States. The data analyzed in this study were collected from the Consumer Products Safety Commission's 2003-2013 National Electronic Injury Surveillance System. There were approximately 53,636 space heater-related thermal burn injuries attributed to portable space heaters from 2003 to 2013. The rate of injuries was relatively constant during the 10-year span. The number of burn injuries was highest during winter months. Young children, older adults, males, and Blacks had the highest rates of injury. The body part most commonly injured was the hand, which accounted for 33.3% of all burn injuries. It is important to understand the characteristics of persons who have an increased risk of portable space heater burn and trip/fall injuries, so that preventative methods and awareness strategies can be used to help reduce the number of annual portable space heater injuries.

  17. MicroDisplay technology: from eyeglass-mounted displays to portable projectors to the Dick Tracy video phone

    NASA Astrophysics Data System (ADS)

    Alvelda, Phillip

    1997-06-01

    MicroDisplay devices are based on a combination of technologies ranging from the extreme integration capability of conventionally fabricated CMOS active-matrix liquid crystal display substrates to proprietary tunable color- filter technology, to optical distortion correction technology for lens-system compensation. All of these technologies were devised to create a line of application- specific integrated circuit single-chip display devices with integrated computing, memory, and communication circuitry. Next-generation portable communication, computer, and consumer electronic devices such as truly portable monitor and TV projectors, eyeglass-clip-on virtual displays, pagers and personal communication services hand-sets, and wristwatch-mounted video phones are all target markets for MicroDisplay technology.

  18. Using Consumer Electronics and Apps in Industrial Environments - Development of a Framework for Dynamic Feature Deployment and Extension by Using Apps on Field Devices

    NASA Astrophysics Data System (ADS)

    Schmitt, Mathias

    2014-12-01

    The aim of this paper is to give a preliminary insight regarding the current work in the field of mobile interaction in industrial environments by using established interaction technologies and metaphors from the consumer goods industry. The major objective is the development and implementation of a holistic app-framework, which enables dynamic feature deployment and extension by using mobile apps on industrial field devices. As a result, field device functionalities can be updated and adapted effectively in accordance with well-known appconcepts from consumer electronics to comply with the urgent requirements of more flexible and changeable factory systems of the future. In addition, a much more user-friendly and utilizable interaction with field devices can be realized. Proprietary software solutions and device-stationary user interfaces can be overcome and replaced by uniform, cross-vendor solutions

  19. A Portable Diode Array Spectrophotometer.

    PubMed

    Stephenson, David

    2016-05-01

    A cheap portable visible light spectrometer is presented. The spectrometer uses readily sourced items and could be constructed by anyone with a knowledge of electronics. The spectrometer covers the wavelength range 450-725 nm with a resolution better than 5 nm. The spectrometer uses a diffraction grating to separate wavelengths, which are detected using a 128-element diode array, the output of which is analyzed using a microprocessor. The spectrum is displayed on a small liquid crystal display screen and can be saved to a micro SD card for later analysis. Battery life (2 × AAA) is estimated to be 200 hours. The overall dimensions of the unit are 120 × 65 × 60 mm, and it weighs about 200 g.

  20. Consumers Are Ready to Accept the Transition to Online and Electronic Records If They Can Be Assured of the Security Measures

    PubMed Central

    Chhanabhai, Prajesh; Holt, Alec

    2007-01-01

    Background Healthcare has entered the electronic domain. This domain has improved data collection and storage abilities while allowing almost instantaneous access and results to data queries. Furthermore, it allows direct communication between healthcare providers and health consumers. The development of privacy, confidentiality, and security principles are necessary to protect consumers' interests against inappropriate access. Studies have shown that the health consumer is the important stakeholder in this process. With the international push toward electronic health records (EHRs), this article presents the importance of secure EHR systems from the public's perspective. Objective To examine the public's perception of the security of electronic systems and report on how their perceptions can shape the building of stronger systems. Methods A cross-sectional survey (September-November 2005) of people attending healthcare providers (n = 400) was conducted in the 4 major cities in New Zealand. Participants were surveyed on computer use, knowledge of EHR-proposed benefits and issues, security issues, and demographics. Results A total of 300 surveys were completed and returned (a 75% response rate), with 180 (60%) being women. One hundred eighty-eight (62.6%) had not heard of EHRs, with those who had heard of them indicating that they were a positive innovation in the health sector. However, 202 (73.3%) participants were highly concerned about the security and privacy of their health records. This feeling was further accentuated when participants were asked about security of electronic systems. Participants were worried about hackers (79.4%), vendor access (72.7%), and malicious software (68%). Participants were also introduced to various security systems, and in each case, over 80% of participants believed that these would make EHR systems more secure. A number of chi-square tests were carried out with each variable, and it was found that there were strong

  1. Consumers are ready to accept the transition to online and electronic records if they can be assured of the security measures.

    PubMed

    Chhanabhai, Prajesh; Holt, Alec

    2007-01-11

    Healthcare has entered the electronic domain. This domain has improved data collection and storage abilities while allowing almost instantaneous access and results to data queries. Furthermore, it allows direct communication between healthcare providers and health consumers. The development of privacy, confidentiality, and security principles are necessary to protect consumers' interests against inappropriate access. Studies have shown that the health consumer is the important stakeholder in this process. With the international push toward electronic health records (EHRs), this article presents the importance of secure EHR systems from the public's perspective. To examine the public's perception of the security of electronic systems and report on how their perceptions can shape the building of stronger systems. A cross-sectional survey (September-November 2005) of people attending healthcare providers (n = 400) was conducted in the 4 major cities in New Zealand. Participants were surveyed on computer use, knowledge of EHR-proposed benefits and issues, security issues, and demographics. A total of 300 surveys were completed and returned (a 75% response rate), with 180 (60%) being women. One hundred eighty-eight (62.6%) had not heard of EHRs, with those who had heard of them indicating that they were a positive innovation in the health sector. However, 202 (73.3%) participants were highly concerned about the security and privacy of their health records. This feeling was further accentuated when participants were asked about security of electronic systems. Participants were worried about hackers (79.4%), vendor access (72.7%), and malicious software (68%). Participants were also introduced to various security systems, and in each case, over 80% of participants believed that these would make EHR systems more secure. A number of chi-square tests were carried out with each variable, and it was found that there were strong relationships between age, location, computer use

  2. Portable neon purification system

    SciTech Connect

    Richardson, R.A.; Schmitt, R.L.

    1995-08-01

    This paper describes the principle design features of a portable neon purification system and the results of the system performance testing. Neon gas replaces air in the Ring Imaging Cherenkov detector without using vacuum, in experiment E781(SELEX) at Fermilab. The portable neon purification system purifies neon gas by, first purging air with CO{sub 2}, freezing the CO{sub 2}, then cryoadsorbing the remaining contaminants. The freezer removes carbon dioxide from a neon gas mixture down to a maximum concentration of 500 parts-per-million (ppm). The charcoal bed adsorber removes nitrogen from neon gas down to a maximum concentration of 100 ppm. The original RICH vessel was designed to hold vacuum but its photomultiplier tube plates were not.

  3. Portable outgas detection apparatus

    DOEpatents

    Haney, Steven Julian; Malinowski, Michael E.

    2004-05-11

    A portable device for detecting surface outgas contaminants of an article includes: (i) a portable housing that has a chamber which is in communication with a port that is adapted to be sealably attached to a surface of the article; (ii) a mass spectrometer that is coupled to the chamber for analyzing gaseous materials in the chamber; and (iii) means for generating a vacuum within the chamber thereby drawing outgas contaminants from the surface of the article into the chamber for analysis by the mass spectrometer. By performing a mass spectrometric analysis of the surface of interest and comparing the data with mass spectrometric data ascertained with the device from a clean surface, the type and amount of outgas contaminants, if any, can be determined.

  4. Portable Laser Laboratory

    SciTech Connect

    Weir, J.T.

    1994-07-01

    A Portable Laser Laboratory (PLL) is being designed and built for the CALIOPE Program tests which will begin in October of 1994. The PLL is designed to give maximum flexibility for evolving laser experiments and can be readily moved by loading it onto a standard truck trailer. The internal configuration for the October experiments will support a two line DIAL system running in the mid-IR. Brief descriptions of the laser and detection systems are included.

  5. Portable Spray Booth

    NASA Technical Reports Server (NTRS)

    Hansen, Timothy D.; Bardwell, Micheal J.

    1996-01-01

    Portable spray booth provides for controlled application of coating materials with high solvent contents. Includes contoured shroud and carbon filter bed limiting concentration of fumes in vicinity. Designed to substitute spraying for brush application of solvent-based adhesive prior to installing rubber waterproof seals over joints between segments of solid-fuel rocket motor. With minor adjustments and modifications, used to apply other solvent-based adhesives, paints, and like.

  6. Portable Spray Booth

    NASA Technical Reports Server (NTRS)

    Hansen, Timothy D.; Bardwell, Micheal J.

    1996-01-01

    Portable spray booth provides for controlled application of coating materials with high solvent contents. Includes contoured shroud and carbon filter bed limiting concentration of fumes in vicinity. Designed to substitute spraying for brush application of solvent-based adhesive prior to installing rubber waterproof seals over joints between segments of solid-fuel rocket motor. With minor adjustments and modifications, used to apply other solvent-based adhesives, paints, and like.

  7. Portable laser laboratory

    NASA Astrophysics Data System (ADS)

    Weir, J. T.

    1994-07-01

    A Portable Laser Laboratory (PLL) is being designed and built for the CALIOPE Program tests which will begin in October of 1994. The PLL is designed to give maximum flexibility for evolving laser experiments and can be readily moved by loading it onto a standard truck trailer. The internal configuration for the October experiments will support a two line DIAL system running in the mid-IR. Brief descriptions of the laser and detection systems are included.

  8. Portable cutting apparatus

    DOEpatents

    Gilmore, R.F.

    1984-07-17

    A remotely operable, portable cutting apparatus detachably secured to the workpiece by laterally spaced clamp assemblies engagable with the workpiece on opposite sides of the intended line of cut. A reciprocal cutter head is mounted between the clamp assemblies and is provided with a traveling abrasive cutting wire adapted to sever the workpiece normal to the longitudinal axis thereof. Dust and debris are withdrawn from the cutting area by a vacuum force through a nozzle mounted on the cutting head.

  9. Portable cutting apparatus

    DOEpatents

    Gilmore, Richard F.

    1986-01-01

    A remotely operable, portable cutting apparatus detachably secured to the workpiece by laterally spaced clamp assemblies engageable with the workpiece on opposite sides of the intended line of cut. A reciprocal cutter head is mounted between the clamp assemblies and is provided with a traveling abrasive cutting wire adapted to sever the workpiece normal to the longitudinal axis thereof. Dust and debris are withdrawn from the cutting area by a vacuum force through a nozzle mounted on the cutting head.

  10. Portable cutting apparatus

    DOEpatents

    Gilmore, Richard F.

    1986-04-01

    A remotely operable, portable cutting apparatus detachably secured to the workpiece by laterally spaced clamp assemblies engageable with the workpiece on opposite sides of the intended line of cut. A reciprocal cutter head is mounted between the clamp assemblies and is provided with a traveling abrasive cutting wire adapted to sever the workpiece normal to the longitudinal axis thereof. Dust and debris are withdrawn from the cutting area by a vacuum force through a nozzle mounted on the cutting head.

  11. Portable Planetariums Teach Science

    NASA Technical Reports Server (NTRS)

    2015-01-01

    With the Internet proving to be the wave of the future, in the 1990s Johnson Space Center awarded grants to Rice University in Houston for developing the world's first Internet-accessible museum kiosk. Further grants were awarded to the school for creating educational software for use in homes and schools, leading to the creation of Museums Teaching Planet Earth Inc. The company has gone on to develop and sell portable planetariums and accompanying educational shows.

  12. Smart portable rehabilitation devices.

    PubMed

    Mavroidis, Constantinos; Nikitczuk, Jason; Weinberg, Brian; Danaher, Gil; Jensen, Katherine; Pelletier, Philip; Prugnarola, Jennifer; Stuart, Ryan; Arango, Roberto; Leahey, Matt; Pavone, Robert; Provo, Andrew; Yasevac, Dan

    2005-07-12

    The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s). In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Laboratory tests of the devices demonstrated that they were able to meet their design

  13. Smart portable rehabilitation devices

    PubMed Central

    Mavroidis, Constantinos; Nikitczuk, Jason; Weinberg, Brian; Danaher, Gil; Jensen, Katherine; Pelletier, Philip; Prugnarola, Jennifer; Stuart, Ryan; Arango, Roberto; Leahey, Matt; Pavone, Robert; Provo, Andrew; Yasevac, Dan

    2005-01-01

    Background The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s). Methods In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Results Laboratory tests of the devices demonstrated that they were able to

  14. A hand-portable digital linear ion trap mass spectrometer.

    PubMed

    Xue, Bing; Sun, Lulu; Huang, Zhengxu; Gao, Wei; Fan, Rongrong; Cheng, Ping; Ding, Li; Ma, Li; Zhou, Zhen

    2016-10-07

    A hand-portable digital linear ion trap mass spectrometer (DLIT-MS) has been developed for VOC analysis. It has a weight of 18 kg with dimensions of 49 cm × 39 cm × 16 cm, and consumes an average power of ca. 60 W. As a result of the introduction of a digital waveform, the DLIT-MS can be driven at a lower voltage (±100 V) to cover a mass range of 30-300 Th with a unit resolution. Compact electronics has been designed to control the DLIT-MS and record mass spectra. The mass drift was reduced after the improvement in electronics to stabilize the digital waveform voltage during the mass scan. Tandem mass spectrometry (MS) has been achieved by using digital asymmetric waveform isolation (DAWI), forward and reverse scan, and collision induced dissociation (CID). The isolation and CID efficiency for methyl salicylate were 83.9% and 81.3%, respectively. A novel buffer gas inlet system was designed to enhance the sensitivity and allow easy and safe use of the instrument. Limits of detection below 1 ppbv were obtained for several mixed gaseous samples.

  15. High intensity portable fluorescent light

    NASA Technical Reports Server (NTRS)

    Kendall, F. B.

    1972-01-01

    Eight high intensity portable fluorescent lights were produced. Three prototype lights were also produced, two of which were subsequently updated to the physical and operational configuration of the qualification and flight units. Positioning of lamp apertures and reflectors in these lights is such that the light is concentrated and intensified in a specific pattern rather than widely diffused. Indium amalgam control of mercury vapor pressure in the lamp gives high output at lamp ambient temperatures up to 105 C. A small amount of amalgam applied to each electrode stem helps to obtain fast warm-up. Shrinking a Teflon sleeve on the tube and potting metal caps on each end of the lamp minimizes dispersion of mercury vapor and glass particles in the event of accidental lamp breakage. Operation at 20 kHz allows the lamps to consume more power than at low frequency, thus increasing their light output and raising their efficiency. When used to expose color photographic film, light from the lamps produces results approximately equal to sunlight.

  16. Consumer Health.

    ERIC Educational Resources Information Center

    Cornacchia, Harold J.

    Consumer health refers to the potential or actual impact upon the consumer, individually or collectively, of any substances, devices, services, or systems that are offered for the supposed purpose of protecting, preserving, or restoring physical or mental health. This book is an effort to help the consumer to choose intelligently in spending for…

  17. Consumer Health.

    ERIC Educational Resources Information Center

    Cornacchia, Harold J.

    Consumer health refers to the potential or actual impact upon the consumer, individually or collectively, of any substances, devices, services, or systems that are offered for the supposed purpose of protecting, preserving, or restoring physical or mental health. This book is an effort to help the consumer to choose intelligently in spending for…

  18. Portable wastewater flow meter

    DOEpatents

    Hunter, Robert M.

    1999-02-02

    A portable wastewater flow meter particularly adapted for temporary use at a single location in measuring the rate of liquid flow in a circular entrance conduit of a sewer manhole both under free flow and submerged, open channel conditions and under fill pipe, surcharged conditions, comprising an apparatus having a cylindrical external surface and an inner surface that constricts the flow through the apparatus in such a manner that a relationship exists between (1) the difference between the static pressure head of liquid flowing through the entrance of the apparatus and the static pressure head of liquid flowing through the constriction, and (2) the rate of liquid flow through the apparatus.

  19. Portable wastewater flow meter

    DOEpatents

    Hunter, Robert M.

    1990-01-01

    A portable wastewater flow meter particularly adapted for temporary use at a single location in measuring the rate of liquid flow in a circular entrance conduit of a sewer manhole both under free flow and submerged, open channel conditions and under full pipe, surcharged conditions, comprising an apparatus having a cylindrical external surface and an inner surface that constricts the flow through the apparatus in such a manner that a relationship exists between (1) the difference between the static pressure head of liquid flowing through the entrance of the apparatus and the static pressure head of liquid flowing through the constriction, and (2) the rate of liquid flow through the apparatus.

  20. Portable data collection device

    DOEpatents

    French, P.D.

    1996-06-11

    The present invention provides a portable data collection device that has a variety of sensors that are interchangeable with a variety of input ports in the device. The various sensors include a data identification feature that provides information to the device regarding the type of physical data produced by each sensor and therefore the type of sensor itself. The data identification feature enables the device to locate the input port where the sensor is connected and self adjust when a sensor is removed or replaced. The device is able to collect physical data, whether or not a function of a time. 7 figs.

  1. Portable wastewater flow meter

    SciTech Connect

    Hunter, Robert M.

    1999-02-02

    A portable wastewater flow meter particularly adapted for temporary use at a single location in measuring the rate of liquid flow in a circular entrance conduit of a sewer manhole both under free flow and submerged, open channel conditions and under fill pipe, surcharged conditions, comprising an apparatus having a cylindrical external surface and an inner surface that constricts the flow through the apparatus in such a manner that a relationship exists between (1) the difference between the static pressure head of liquid flowing through the entrance of the apparatus and the static pressure head of liquid flowing through the constriction, and (2) the rate of liquid flow through the apparatus.

  2. Portable data collection device

    DOEpatents

    French, Patrick D.

    1996-01-01

    The present invention provides a portable data collection device that has a variety of sensors that are interchangeable with a variety of input ports in the device. The various sensors include a data identification feature that provides information to the device regarding the type of physical data produced by each sensor and therefore the type of sensor itself. The data identification feature enables the device to locate the input port where the sensor is connected and self adjust when a sensor is removed or replaced. The device is able to collect physical data, whether or not a function of a time.

  3. Portable pathogen detection system

    DOEpatents

    Colston, Billy W.; Everett, Matthew; Milanovich, Fred P.; Brown, Steve B.; Vendateswaran, Kodumudi; Simon, Jonathan N.

    2005-06-14

    A portable pathogen detection system that accomplishes on-site multiplex detection of targets in biological samples. The system includes: microbead specific reagents, incubation/mixing chambers, a disposable microbead capture substrate, and an optical measurement and decoding arrangement. The basis of this system is a highly flexible Liquid Array that utilizes optically encoded microbeads as the templates for biological assays. Target biological samples are optically labeled and captured on the microbeads, which are in turn captured on an ordered array or disordered array disposable capture substrate and then optically read.

  4. Application Portable Parallel Library

    NASA Technical Reports Server (NTRS)

    Cole, Gary L.; Blech, Richard A.; Quealy, Angela; Townsend, Scott

    1995-01-01

    Application Portable Parallel Library (APPL) computer program is subroutine-based message-passing software library intended to provide consistent interface to variety of multiprocessor computers on market today. Minimizes effort needed to move application program from one computer to another. User develops application program once and then easily moves application program from parallel computer on which created to another parallel computer. ("Parallel computer" also include heterogeneous collection of networked computers). Written in C language with one FORTRAN 77 subroutine for UNIX-based computers and callable from application programs written in C language or FORTRAN 77.

  5. Portable drilling mud system

    SciTech Connect

    Etter, R. W.; Briggs, J. M.

    1984-10-02

    A portable well drilling mud storage and recirculation unit includes a mud storage tank mounted on an over-the-road semi-trailer having an engine driven circulating pump mounted onboard and adapted to withdraw mud from the tank for circulation to the well and for recirculation through a set of mud agitating nozzles disposed in the bottom of the tank. A mud degassing vessel, a solids separator unit and an additive blending unit are all mounted above the tank. The degassing vessel is supported by hydraulic cylinder actuators for movement between a retracted transport position and a vertically elevated working position.

  6. Application Portable Parallel Library

    NASA Technical Reports Server (NTRS)

    Cole, Gary L.; Blech, Richard A.; Quealy, Angela; Townsend, Scott

    1995-01-01

    Application Portable Parallel Library (APPL) computer program is subroutine-based message-passing software library intended to provide consistent interface to variety of multiprocessor computers on market today. Minimizes effort needed to move application program from one computer to another. User develops application program once and then easily moves application program from parallel computer on which created to another parallel computer. ("Parallel computer" also include heterogeneous collection of networked computers). Written in C language with one FORTRAN 77 subroutine for UNIX-based computers and callable from application programs written in C language or FORTRAN 77.

  7. Portable solar cooker

    SciTech Connect

    Way, L.V.

    1980-09-02

    A portable solar cooker of the type having an insulated housing with an oven compartment enclosed therein and associated reflector elements is adapted for cooking with the housing and oven compartment in a tilted or level position. When employing only the tilting mode for tracking the sun, reflecting panels are removably attached to the top of the cooker housing. When there is a need to maintain the oven compartment level while tracking the sun during the cooking operation, the reflecting panels are removably mounted on a pivotal frame connected to a telescoping strip assembly which, in turn, is removably mounted on the topside of the cooker housing.

  8. Portable Extensible Viewer

    NASA Technical Reports Server (NTRS)

    Horowitz, Jay G.

    1997-01-01

    The use of Nonuniform Rational B-Splines (NURBS) to represent geometry and data offers a standard way to facilitate the multidisciplinary analysis and design of aeropropulsion products. Using standard geometry defined by NURBS throughout design, analysis, part definition, manufacture, and test processes saves money and time. The Portable Extensible Viewer (PEV) offers engineers of different disciplines a means to view and manipulate NURBS geometry and associated data. Under the guidance of a team of Lewis, Boeing Company, and Navy personnel, PEV was developed by NASA Lewis Research Center's Computer Services Division for Lewis' Interdisciplinary Technology Office. The aeropropulsion industry provided input to the design requirements.

  9. Portable classroom leads to partnership.

    PubMed

    Le Ber, Jeanne Marie; Lombardo, Nancy T; Weber, Alice; Bramble, John

    2004-01-01

    Library faculty participation on the School of Medicine Curriculum Steering Committee led to a unique opportunity to partner technology and teaching utilizing the library's portable wireless classroom. The pathology lab course master expressed a desire to revise the curriculum using patient cases and direct access to the Web and library resources. Since the pathology lab lacked computers, the library's portable wireless classroom provided a solution. Originally developed to provide maximum portability and flexibility, the wireless classroom consists of ten laptop computers configured with wireless cards and an access point. While the portable wireless classroom led to a partnership with the School of Medicine, there were additional benefits and positive consequences for the library.

  10. 300 WATT PORTABLE THERMOELECTRIC GENERATOR.

    DTIC Science & Technology

    GENERATORS , *ELECTRIC POWER PRODUCTION, POWER SUPPLIES, THERMOELECTRICITY, THERMOELECTRICITY, PORTABLE EQUIPMENT, THERMOCOUPLES, ENERGY CONVERSION, LIFE EXPECTANCY(SERVICE LIFE), HEAT TRANSFER, VOLTAGE REGULATORS.

  11. Portable Virtual Training Units

    NASA Technical Reports Server (NTRS)

    Malone, Reagan; Johnston, Alan

    2015-01-01

    The Mission Operations Lab initiated a project to design, develop, deliver, test, and validate a unique training system for astronaut and ground support personnel. In an effort to keep training costs low, virtual training units (VTUs) have been designed based on images of actual hardware and manipulated by a touch screen style interface for ground support personnel training. This project helped modernized the training system and materials by integrating them with mobile devices for training when operators or crew are unavailable to physically train in the facility. This project also tested the concept of a handheld remote device to control integrated trainers using International Space Station (ISS) training simulators as a platform. The portable VTU can interface with the full-sized VTU, allowing a trainer co-located with a trainee to remotely manipulate a VTU and evaluate a trainee's response. This project helped determine if it is useful, cost effective, and beneficial for the instructor to have a portable handheld device to control the behavior of the models during training. This project has advanced NASA Marshall Space Flight Center's (MSFC's) VTU capabilities with modern and relevant technology to support space flight training needs of today and tomorrow.

  12. An ultra-low-power ambient light sensor for portable devices

    NASA Astrophysics Data System (ADS)

    Cho, Soon-Ik; Kim, Yun-Jeong; Lee, Jong-Ho; Baek, Kwang-Hyun; Kim, Suki

    2009-02-01

    Power management is one of the most important issues in portable electronics like cell phone, PDA, UMPC, GPS, MP3 player and laptop computer. Ambient Light Sensors are getting popular as a most effective solution to extend battery lifetime for these devices. This paper provides basic information about ambient light sensors on a general level and introduces an ultra low-power ambient light sensor for portable electronics. The implemented ambient light sensor converts light illuminance to 5-digital codes every 300ms which can measure illuminance from 10 to 1000 Lux consuming only 5uA. An IR-reject optical filter and a built-in integrating analog-to-digital converter reduce influences of infrared ray and 50Hz/60Hz noise from artificial light sources respectively. The ambient light sensor is fabricated in a standard CMOS 0.5-um process technology. Test results show that the implemented ambient light sensor has incandescent/fluorescent light sensitivity ratio around 2.3.

  13. Development of an integrated e-health tool for people with, or at high risk of, cardiovascular disease: The Consumer Navigation of Electronic Cardiovascular Tools (CONNECT) web application.

    PubMed

    Neubeck, Lis; Coorey, Genevieve; Peiris, David; Mulley, John; Heeley, Emma; Hersch, Fred; Redfern, Julie

    2016-12-01

    Cardiovascular disease is the leading killer globally and secondary prevention substantially reduces risk. Uptake of, and adherence to, face-to-face preventive programs is often low. Alternative models of care are exploiting the prominence of technology in daily life to facilitate lifestyle behavior change. To inform the development of a web-based application integrated with the primary care electronic health record, we undertook a collaborative user-centered design process to develop a consumer-focused e-health tool for cardiovascular disease risk reduction. A four-phase iterative process involved ten multidisciplinary clinicians and academics (primary care physician, nurses and allied health professionals), two design consultants, one graphic designer, three software developers and fourteen proposed end-users. This 18-month process involved, (1) defining the target audience and needs, (2) pilot testing and refinement, (3) software development including validation and testing the algorithm, (4) user acceptance testing and beta testing. From this process, researchers were able to better understand end-user needs and preferences, thereby improving and enriching the increasingly detailed system designs and prototypes for a mobile responsive web application. We reviewed 14 relevant applications/websites and sixteen observational and interventional studies to derive a set of core components and ideal features for the system. These included the need for interactivity, visual appeal, credible health information, virtual rewards, and emotional and physical support. The features identified as essential were: (i) both mobile and web-enabled 'apps', (ii) an emphasis on medication management, (iii) a strong psychosocial support component. Subsequent workshops (n=6; 2×1.5h) informed the development of functionality and lo-fidelity sketches of application interfaces. These ideas were next tested in consumer focus groups (n=9; 3×1.5h). Specifications for the application were

  14. Portable Hyperbaric Chamber

    NASA Technical Reports Server (NTRS)

    Schneider, William C. (Inventor); Locke, James P. (Inventor); DeLaFuente, Horacio (Inventor)

    2001-01-01

    A portable, collapsible hyperbaric chamber was developed. A toroidal inflatable skeleton provides initial structural support for the chamber, allowing the attendant and/or patient to enter the chamber. Oval hatches mate against bulkhead rings, and the hyperbaric chamber is pressurized. The hatches seal against an o-ring, and the internal pressure of the chamber provides the required pressure against the hatch to maintain an airtight seal. In the preferred embodiment, the hyperbaric chamber has an airlock to allow the attendant to enter and exit the patient chamber during treatment. Visual communication is provided through portholes in the patient and/or airlock chamber. Life monitoring and support systems are in communication with the interior of the hyperbaric chamber and/or airlock chamber through conduits and/or sealed feed-through connectors into the hyperbaric chamber.

  15. Portable Medical System

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Portable Medical Status and Treatment System (PMSTS) is designed for use in remote areas where considerable time may elapse before a patient can be transported to a hospital. First units were delivered to the Department of Transportation last year and tested in two types of medical emergency environments: one in a rural Pennsylvania community and another aboard a U.S. Coast Guard rescue helicopter operating along Florida's Gulf Coast. The system has the capability to transmit vital signs to a distantly located physician, who can perform diagnosis and relay treatment instructions to the attendant at the scene. The battery powered PMSTS includes a vital signs monitor and a defibrillator. Narco has also developed a companion system, called Porta-Fib III designed for use in a hospital environment with modifications accordingly. Both systems are offshoots of an earlier NASA project known as the Physician's Black Bag developed by Telecare, Inc., a company now acquired by NARCO.

  16. Portable Radiation Detectors

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Through a Small Business Innovation Research (SBIR) contract from Kennedy Space Center, General Pneumatics Corporation's Western Research Center satisfied a NASA need for a non-clogging Joule-Thomson cryostat to provide very low temperature cooling for various sensors. This NASA-supported cryostat development played a key part in the development of more portable high-purity geranium gamma-ray detectors. Such are necessary to discern between the radionuclides in medical, fuel, weapon, and waste materials. The outcome of the SBIR project is a cryostat that can cool gamma-ray detectors, without vibration, using compressed gas that can be stored compactly and indefinitely in a standby mode. General Pneumatics also produces custom J-T cryostats for other government, commercial and medical applications.

  17. Portable multiplicity counter

    DOEpatents

    Newell, Matthew R.; Jones, David Carl

    2009-09-01

    A portable multiplicity counter has signal input circuitry, processing circuitry and a user/computer interface disposed in a housing. The processing circuitry, which can comprise a microcontroller integrated circuit operably coupled to shift register circuitry implemented in a field programmable gate array, is configured to be operable via the user/computer interface to count input signal pluses receivable at said signal input circuitry and record time correlations thereof in a total counting mode, coincidence counting mode and/or a multiplicity counting mode. The user/computer interface can be for example an LCD display/keypad and/or a USB interface. The counter can include a battery pack for powering the counter and low/high voltage power supplies for biasing external detectors so that the counter can be configured as a hand-held device for counting neutron events.

  18. Portable active interrogation system.

    SciTech Connect

    Moss, C. E.; Brener, M. W.; Hollas, C. L.; Myers, W. L.

    2004-01-01

    The system consists of a pulsed DT neutron generator (5 x 10{sup 7} n/s) and a portable but high intrinsic efficiency, custom-designed, polyethylene-moderated {sup 3}He neutron detector. A multichannel scaler card in a ruggedized laptop computer acquires the data. A user-friendly LabVIEW program analyzes and displays the data. The program displays a warning message when highly enriched uranium or any other fissionable materials is detected at a specified number of sigmas above background in the delayed region between pulses. This report describes the system and gives examples of the response of the system to highly enriched uranium and some other fissionable materials, at several distances and with various shielding materials.

  19. Portable appliance security apparatus

    NASA Technical Reports Server (NTRS)

    Kerley, J. J. (Inventor)

    1981-01-01

    An apparatus for securing a small computer, or other portable appliance, against theft is described. It is comprised of a case having an open back through which the computer is installed or removed. Guide members in the form of slots are formed in a rear portion of opposite walls of the case for receiving a back plate to cover the opening and thereby secure the computer within the case. An opening formed in the top wall of the case exposes the keyboard and display of the computer. The back plate is locked in the closed position by a key-operated plug type lock. The lock is attached to one end of a hold down cable, the opposite end thereof being secured to a desk top or other stationary object. Thus, the lock simultaneously secures the back plate to the case and retains the case to the stationary object.

  20. Portable Hyperbaric Chamber

    NASA Technical Reports Server (NTRS)

    Schneider, William C. (Inventor); Locke, James P. (Inventor); DeLaFuente, Horacio (Inventor)

    2001-01-01

    A portable, collapsible hyperbaric chamber was developed. A toroidal inflatable skeleton provides initial structural support for the chamber, allowing the attendant and/or patient to enter the chamber. Oval hatches mate against bulkhead rings, and the hyperbaric chamber is pressurized. The hatches seal against an o-ring, and the internal pressure of the chamber provides the required pressure against the hatch to maintain an airtight seal. In the preferred embodiment, the hyperbaric chamber has an airlock to allow the attendant to enter and exit the patient chamber during treatment. Visual communication is provided through portholes in the patient and/or airlock chamber. Life monitoring and support systems are in communication with the interior of the hyperbaric chamber and/or airlock chamber through conduits and/or sealed feed-through connectors into the hyperbaric chamber.

  1. Identification of V-type nerve agents in vapor samples using a field-portable capillary gas chromatography/membrane-interfaced electron ionization quadrupole mass spectrometry instrument with Tri-Bed concentrator and fluoridating conversion tube.

    PubMed

    Ohrui, Y; Nagoya, T; Kurimata, N; Sodeyama, M; Seto, Y

    2017-07-01

    A field-portable gas chromatography-mass spectrometry (GC-MS) system (Hapsite ER) was evaluated for the detection of nonvolatile V-type nerve agents (VX and Russian VX (RVX)) in the vapor phase. The Hapsite ER system consists of a Tri-Bed concentrator gas sampler, a nonpolar low thermal-mass capillary GC column and a hydrophobic membrane-interfaced electron ionization quadrupole mass spectrometer evacuated by a non-evaporative getter pump. The GC-MS system was attached to a VX-G fluoridating conversion tube containing silver nitrate and potassium fluoride. Sample vapors of VX and RVX were converted into O-ethyl methylphosphonofluoridate (EtGB) and O-isobutyl methylphosphonofluoridate (iBuGB), respectively. These fluoridated derivatives were detected within 10 min. No compounds were detected when the VX and RVX samples were analyzed without the conversion tube. A vapor sample of tabun (GA) was analyzed, in which GA and O-ethyl N,N-dimethylphosphoramidofluoridate were detected. The molar recovery percentages of EtGB and iBuGB from VX and RVX vapors varied from 0.3 to 17%, which was attributed to variations in the vaporization efficiency of the glass vapor container. The conversion efficiencies of the VX-G conversion tube for VX and RVX to their phosphonate derivatives were estimated to be 40%. VX and RVX vapors were detected at concentrations as low as 0.3 mg m(-3) . Gasoline vapor was found to interfere with the analyses of VX and RVX. In the presence of 160 mg m(-3) gasoline, the detection limits of VX and RVX vapor were increased to 20 mg m(-3) . Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  2. A Portable Infrasonic Detection System

    NASA Technical Reports Server (NTRS)

    Shams, Qamar A.; Burkett, Cecil G.; Zuckerwar, Allan J.; Lawrenson, Christopher C.; Masterman, Michael

    2008-01-01

    During last couple of years, NASA Langley has designed and developed a portable infrasonic detection system which can be used to make useful infrasound measurements at a location where it was not possible previously. The system comprises an electret condenser microphone, having a 3-inch membrane diameter, and a small, compact windscreen. Electret-based technology offers the lowest possible background noise, because Johnson noise generated in the supporting electronics (preamplifier) is minimized. The microphone features a high membrane compliance with a large backchamber volume, a prepolarized backplane and a high impedance preamplifier located inside the backchamber. The windscreen, based on the high transmission coefficient of infrasound through matter, is made of a material having a low acoustic impedance and sufficiently thick wall to insure structural stability. Close-cell polyurethane foam has been found to serve the purpose well. In the proposed test, test parameters will be sensitivity, background noise, signal fidelity (harmonic distortion), and temporal stability. The design and results of the compact system, based upon laboratory and field experiments, will be presented.

  3. Characteristics, perceived side effects and benefits of electronic cigarette use: a worldwide survey of more than 19,000 consumers.

    PubMed

    Farsalinos, Konstantinos E; Romagna, Giorgio; Tsiapras, Dimitris; Kyrzopoulos, Stamatis; Voudris, Vassilis

    2014-04-22

    Electronic cigarette (EC) use has grown exponentially over the past few years. The purpose of this survey was to assess the characteristics and experiences of a large sample of EC users and examine the differences between those who partially and completely substituted smoking with EC use. A questionnaire was prepared, translated into 10 different languages and uploaded in an online survey tool. EC users were asked to participate irrespective of their current smoking status. Participants were divided according to their smoking status at the time of participation in two subgroups: former smokers and current smokers. In total, 19,414 participants were included in the analysis, with 88 of them (0.5%) reported not being smokers at the time of EC use initiation. Complete substitution of smoking was reported by 81.0% of participants (former smokers) while current smokers had reduced smoking consumption from 20 to 4 cigarettes per day. They were using ECs for a median of 10 months. They initiated EC use with a median of 18 mg/mL nicotine-concentration liquids; 21.5% used higher than 20 mg/mL. Only 3.5% of participants were using 0-nicotine liquids at the time of the survey. Former smokers were highly dependent (Fagerström Test for Cigarette Dependence = 7) and were heavier smokers (21 cigarettes per day when smoking) compared to current smokers. The most important reasons for initiating EC use for both subgroups was to reduce the harm associated with smoking and to reduce exposure of family members to second-hand smoking. Most considered ECs as less harmful than tobacco cigarettes, while 11.0% considered them absolutely harmless. Side effects were reported by more than half of the participants (59.8%), with the most common being sore/dry mouth and throat; side effects were mild and in most cases were subsequently resolved (partially or completely). Participants experienced significant benefits in physical status and improvements in pre-existing disease conditions

  4. A Trusted Portable Computing Device

    NASA Astrophysics Data System (ADS)

    Ming-wei, Fang; Jun-jun, Wu; Peng-fei, Yu; Xin-fang, Zhang

    A trusted portable computing device and its security mechanism were presented to solve the security issues, such as the attack of virus and Trojan horse, the lost and stolen of storage device, in mobile office. It used smart card to build a trusted portable security base, virtualization to create a secure virtual execution environment, two-factor authentication mechanism to identify legitimate users, and dynamic encryption to protect data privacy. The security environment described in this paper is characteristic of portability, security and reliability. It can meet the security requirement of mobile office.

  5. Morphology, Spatial Distribution, and Concentration of Flame Retardants in Consumer Products and Environmental Dusts using Scanning Electron Microscopy and Raman Micro-spectroscopy

    PubMed Central

    WAGNER, JEFF; GHOSAL, SUTAPA; WHITEHEAD, TODD; METAYER, CATHERINE

    2013-01-01

    We characterized flame retardant (FR) morphologies and spatial distributions in 7 consumer products and 7 environmental dusts to determine their implications for transfer mechanisms, human exposure, and the reproducibility of gas chromatography-mass spectrometry (GC-MS) dust measurements. We characterized individual particles using scanning electron microscopy / energy dispersive x-ray spectroscopy (SEM/EDS) and Raman micro-spectroscopy (RMS). Samples were screened for the presence of 3 FR constituents (bromine, phosphorous, non-salt chlorine) and 2 metal synergists (antimony and bismuth). Subsequent analyses of select samples by RMS enabled molecular identification of the FR compounds and matrix materials. The consumer products and dust samples possessed FR elemental weight percents of up to 36% and 31%, respectively. We identified 24 FR-containing particles in the dust samples and classified them into 9 types based on morphology and composition. We observed a broad range of morphologies for these FR-containing particles, suggesting FR transfer to dust via multiple mechanisms. We developed an equation to describe the heterogeneity of FR-containing particles in environmental dust samples. The number of individual FR-containing particles expected in a 1-mg dust sample with a FR concentration of 100 ppm ranged from <1 to >1000 particles. The presence of rare, high-concentration bromine particles was correlated with decabromodiphenyl ether concentrations obtained via GC-MS. When FRs are distributed heterogeneously in highly concentrated dust particles, human exposure to FRs may be characterized by high transient exposures interspersed by periods of low exposure, and GC-MS FR concentrations may exhibit large variability in replicate subsamples. Current limitations of this SEM/EDS technique include potential false negatives for volatile and chlorinated FRs and greater quantitation uncertainty for brominated FR in aluminum-rich matrices. PMID:23739093

  6. 29 CFR 1917.119 - Portable ladders.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... construction requirements of the following standards: ANSI A14.1-1990, Safety Requirements for Portable Wood... otherwise specified. (b) Standards for existing manufactured portable ladders. (1) Rungs of manufactured... ladder length. (c) Standards for manufactured portable ladders. Portable manufactured ladders obtained...

  7. 49 CFR 176.137 - Portable magazine.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Portable magazine. 176.137 Section 176.137... Requirements for Class 1 (Explosive) Materials Stowage § 176.137 Portable magazine. (a) Each portable magazine... wood, a portable magazine must be framed of nominal 5 cm × 10 cm (2×4 inch) lumber, and sheathed...

  8. 49 CFR 176.137 - Portable magazine.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Portable magazine. 176.137 Section 176.137... Requirements for Class 1 (Explosive) Materials Stowage § 176.137 Portable magazine. (a) Each portable magazine... wood, a portable magazine must be framed of nominal 5 cm × 10 cm (2×4 inch) lumber, and sheathed...

  9. 49 CFR 176.137 - Portable magazine.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Portable magazine. 176.137 Section 176.137... Requirements for Class 1 (Explosive) Materials Stowage § 176.137 Portable magazine. (a) Each portable magazine... wood, a portable magazine must be framed of nominal 5 cm × 10 cm (2×4 inch) lumber, and sheathed...

  10. 49 CFR 176.137 - Portable magazine.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Portable magazine. 176.137 Section 176.137... Requirements for Class 1 (Explosive) Materials Stowage § 176.137 Portable magazine. (a) Each portable magazine... wood, a portable magazine must be framed of nominal 5 cm × 10 cm (2×4 inch) lumber, and sheathed...

  11. 49 CFR 176.137 - Portable magazine.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Portable magazine. 176.137 Section 176.137... Requirements for Class 1 (Explosive) Materials Stowage § 176.137 Portable magazine. (a) Each portable magazine... wood, a portable magazine must be framed of nominal 5 cm × 10 cm (2×4 inch) lumber, and sheathed with...

  12. [Development of a portable dynamic state ECG based on DSP].

    PubMed

    Song, Li; Meng, Qing-jian; Zhang, Guang-yu; Cao, Wei-fang

    2009-11-01

    The Portable dynamic state electrocardiogram collecting system is introduced by using TMS302VC5402, TLC320AD50C, liquid crystal display model, and so on. This dissertation describes the work principle of the system and uses the united algorithm based on wavelet to identify and locate the ECG characteristic waves. This system has as follows of advantages: big memory, low noise,high common mode rejection ratio, the low power consume,the long record time etc.

  13. Advanced Microdisplays for Portable Systems

    DTIC Science & Technology

    1999-08-01

    THROUGH SCIENCE mm WE DEFEND TECHNICAL REPORT NATICK/TR-99/037 AD ADVANCED MICRODISPLAYS FOR PORTABLE SYSTEMS by Phillip Alvelda Michael...1996 - 19 October 1998 4. TITLE AND SUBTITLE ADVANCED MICRODISPLAYS FOR PORTABLE SYSTEMS 6. AUTHOR(S) Phillip Alvelda , Michael Bolotski, Ramon...MIT’s Artificial Intelligence Laboratory which forms the basis for this proposal. Under DARPA funding, Mr. Alvelda and Mr. Knight developed the highest

  14. Portable Slot-Sizing Tool

    NASA Technical Reports Server (NTRS)

    Zuver, Nelson T.

    1987-01-01

    Portable milling tool consisting of air-motor-driven cutter held in adjustable moving slide made possible local removal of chromium plating in close-tolerance, onsite remachining and sizing of half-hole slots on longeron bridges. Made from commercially available parts, including air motor capable of variable speeds up to 900 rpm, ball end mill, revolving handle, two miter gears, and ball slide. Adaptation of portable sizing tool useful for field modification of such large equipment as trucks, aircraft, and ships.

  15. Open Component Portability Infrastructure (OPENCPI)

    DTIC Science & Technology

    2013-03-01

    OPEN COMPONENT PORTABILITY INFRASTRUCTURE (OPENCPI) MERCURY FEDERAL SYSTEMS, INC. MARCH 2013 FINAL TECHNICAL REPORT...NUMBER OC 5f. WORK UNIT NUMBER PI 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Mercury Federal Systems, Inc. 1901 South Bell Street, Suite...Component Portability Infrastructure (OPENCPI) ,” AFRL-RI-RS-TR- 2009-257, Mercury Federal Systems, Inc., Arlington, VA, Nov 2009. 2. Kulp, J., “OpenCPI

  16. Identification of chemical warfare agents from vapor samples using a field-portable capillary gas chromatography/membrane-interfaced electron ionization quadrupole mass spectrometry instrument with Tri-Bed concentrator.

    PubMed

    Nagashima, Hisayuki; Kondo, Tomohide; Nagoya, Tomoki; Ikeda, Toru; Kurimata, Naoko; Unoke, Shohei; Seto, Yasuo

    2015-08-07

    A field-portable gas chromatograph-mass spectrometer (Hapsite ER system) was evaluated for the detection of chemical warfare agents (CWAs) in the vapor phase. The system consisted of Tri-Bed concentrator gas sampler (trapping time: 3s(-1)min), a nonpolar low thermal-mass capillary gas chromatography column capable of raising temperatures up to 200°C, a hydrophobic membrane-interfaced electron ionization quadrupole mass spectrometer evacuated by a non-evaporative getter pump for data acquisition, and a personal computer for data analysis. Sample vapors containing as little as 22μg sarin (GB), 100μg soman (GD), 210μg tabun (GA), 55μg cyclohexylsarin (GF), 4.8μg sulfur mustard, 390μg nitrogen mustard 1, 140μg of nitrogen mustard 2, 130μg nitrogen mustard 3, 120μg of 2-chloroacetophenone and 990μg of chloropicrin per cubic meter could be confirmed after Tri-Bed micro-concentration (for 1min) and automated AMDIS search within 12min. Using manual deconvolution by background subtraction of neighboring regions on the extracted ion chromatograms, the above-mentioned CWAs could be confirmed at lower concentration levels. The memory effects were also examined and we found that blister agents showed significantly more carry-over than nerve agents. Gasoline vapor was found to interfere with the detection of GB and GD, raising the concentration limits for confirmation in the presence of gasoline by both AMDIS search and manual deconvolution; however, GA and GF were not subject to interference by gasoline. Lewisite 1, and o-chlorobenzylidene malononitrile could also be confirmed by gas chromatography, but it was hard to quantify them. Vapors of phosgene, chlorine, and cyanogen chloride could be confirmed by direct mass spectrometric detection at concentration levels higher than 2, 140, and 10mg/m(3) respectively, by bypassing the micro-concentration trap and gas chromatographic separation. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. The p-EVES study design and methodology: a randomised controlled trial to compare portable electronic vision enhancement systems (p-EVES) to optical magnifiers for near vision activities in visual impairment.

    PubMed

    Taylor, John; Bambrick, Rachel; Dutton, Michelle; Harper, Robert; Ryan, Barbara; Tudor-Edwards, Rhiannon; Waterman, Heather; Whitaker, Chris; Dickinson, Chris

    2014-09-01

    To describe the study design and methodology for the p-EVES study, a trial designed to determine the effectiveness, cost-effectiveness and acceptability of portable Electronic Vision Enhancement System (p-EVES) devices and conventional optical low vision aids (LVAs) for near tasks in people with low vision. The p-EVES study is a prospective two-arm randomised cross-over trial to test the hypothesis that, in comparison to optical LVAs, p-EVES can be: used for longer duration; used for a wider range of tasks than a single optical LVA and/or enable users to do tasks that they were not able to do with optical LVAs; allow faster performance of instrumental activities of daily living; and allow faster reading. A total of 100 adult participants with visual impairment are currently being recruited from Manchester Royal Eye Hospital and randomised into either Group 1 (receiving the two interventions A and B in the order AB), or Group 2 (receiving the two interventions in the order BA). Intervention A is a 2-month period with conventional optical LVAs and a p-EVES device, and intervention B is a 2-month period with conventional optical LVAs only. The study adopts a mixed methods approach encompassing a broad range of outcome measures. The results will be obtained from the following primary outcome measures: Manchester Low Vision Questionnaire, capturing device 'usage' data (which devices are used, number of times, for what purposes, and for how long) and the MNRead test, measuring threshold print size, critical print size, and acuity reserve in addition to reading speed at high (≈90%) contrast. Results will also be obtained from a series of secondary outcome measures which include: assessment of timed instrumental activities of daily living and a 'near vision' visual functioning questionnaire. A companion qualitative study will permit comparison of results on how, where, and under what circumstances, p-EVES devices and LVAs are used in daily life. A health economic

  18. Protocol for a randomised crossover trial to evaluate patient and nurse satisfaction with electronic and elastomeric portable infusion pumps for the continuous administration of antibiotic therapy in the home: the Comparing Home Infusion Devices (CHID) study.

    PubMed

    Hobbs, Jodie G; Ryan, Melissa K; Ritchie, Brett; Sluggett, Janet K; Sluggett, Andrew J; Ralton, Lucy; Reynolds, Karen J

    2017-07-31

    Previous studies comparing satisfaction with electronic and elastomeric infusion pumps are limited, and improvements in size and usability of electronic pumps have since occurred. The Comparing Home Infusion Devices (CHID) study plans to assess patient and nurse satisfaction with an elastomeric and electronic pump for delivering intravenous antibiotic treatment in the home. Secondary objectives are to determine pump-related complications and actual antibiotic dose administered, evaluate temperature variation and compare pump operating costs. The CHID study will be a randomised, crossover trial. A trained research nurse will recruit patients with infectious disease aged ≥18 years and prescribed ≥8 days of continuous intravenous antibiotic therapy from the Royal Adelaide Hospital (RAH) (Adelaide, Australia). Patients will be randomised to receive treatment at home via an elastomeric (Baxter Infusor) or an electronic (ambIT Continuous) infusion pump for 4-7 days, followed by the other for a further 4-7 days. Patient satisfaction will be assessed by a 10-item survey to be completed at the end of each arm. Nurse satisfaction will be assessed by a single 24-item survey. Patient logbooks and case notes from clinic visits will be screened to identify complications. Pumps/infusion bags will be weighed to estimate the volume of solution delivered. Temperature sensors will record skin and ambient temperatures during storage and use of the pumps throughout the infusion period. Costs relating to pumps, consumables, antibiotics and servicing will be determined. Descriptive statistics will summarise study data. This study has been approved by the RAH Human Research Ethics Committee (HREC/16/RAH/133 R20160420, version 6.0, 5 September 2016). Study results will be disseminated through peer-reviewed publications and conference presentations. The CHID study will provide key insights into patient and provider satisfaction with elastomeric and electronic infusion pumps and inform

  19. Reduction in wound healing times, cost of consumables and number of visits treated through the implementation of an electronic wound care system in rural Australia.

    PubMed

    Khalil, Hanan; Cullen, Marianne; Chambers, Helen; Carroll, Matthew; Walker, Judi

    2016-10-01

    Globally, wound care costs the health care system 2-3% of the total expenditure on health, which equates to several billion dollars annually. To date, there are little data on the cost and healing rates of various wounds. This has been partly because of the difficulty in tracking wound management as the majority of wound care data has been focused on retrospective data from hospitals, general practice clinics and aged care facilities. This study reports on wound healing and cost of wounds collected from a larger project using the mobile wound care (MWC) electronic documentation system, which has been described elsewhere. The study involved 2350 clients from four health service districts in the Gippsland region in rural Australia who received treatments as part of the MWC research project (2010-2012), with a total of 3726 wounds identified (so an average of 1·6 wounds per client). By the end of the data collection period, 81% of these wounds had healed. A significant drop in healing time, cost of consumables and number of visits was found across the 3-year period. © 2015 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  20. The Future of Portable Devices is the "PITs"

    ERIC Educational Resources Information Center

    Peters, Tom; Bell, Lori

    2006-01-01

    According to recent media reports, MP3 players are one of the hottest gift item these days, particularly for adolescents. The broad success of these devices, however, has revealed flaws in the designers' noninclusive thinking. The accessibility challenges for these players are similar to those for other portable electronic gadgets, such as PDAs…

  1. The Future of Portable Devices is the "PITs"

    ERIC Educational Resources Information Center

    Peters, Tom; Bell, Lori

    2006-01-01

    According to recent media reports, MP3 players are one of the hottest gift item these days, particularly for adolescents. The broad success of these devices, however, has revealed flaws in the designers' noninclusive thinking. The accessibility challenges for these players are similar to those for other portable electronic gadgets, such as PDAs…

  2. Consumer Concerns.

    ERIC Educational Resources Information Center

    Idleman, Hillis K.

    The module deals mainly with some of the service problems experienced by consumers, examines the causes of some problems, and suggests some solutions, attempting to present the standpoint of the producer as well as the buyer and user. The module may be presented as a semester or part semester course. Organized by expected student understandings,…

  3. Consumer Education.

    ERIC Educational Resources Information Center

    Heintz, Amy D., Comp.

    The curriculum guide is intended as a source to help teachers plan consumer education classes in Nevada, from junior high school through the adult level. Developed for a semester's (18 weeks) separate course of study, using individual or group instruction, the guide may be expanded to meet the needs of a full year. Each unit can be taught as an…

  4. Consumer Health.

    ERIC Educational Resources Information Center

    Harrelson, Orvis A.; And Others

    This guide to consumer health contains two parts, the first of which covers consumerism, cosmetics (aids for skin problems, dandruff, deodorants, dentifrices), food shopping, and clothes shopping. Part 2 discusses health quackery, including arthritis quackery, and mail-order "doctoring", food quackery, weight-reducing products, and how…

  5. Consumer Skills.

    ERIC Educational Resources Information Center

    Gindele, John; And Others

    1981-01-01

    Consumer education activities for secondary, adult, and special needs students are described in "What Does It Cost to Run a Home?" by John and Joseph Gindele; "Taking the Show on the Road" by Linda Lewis; "Special Home Ec Program" by Marty Nelson; and "Understanding Civil Law" by Michael Weis. (SK)

  6. Consumer Health.

    ERIC Educational Resources Information Center

    Harrelson, Orvis A.; And Others

    This guide to consumer health contains two parts, the first of which covers consumerism, cosmetics (aids for skin problems, dandruff, deodorants, dentifrices), food shopping, and clothes shopping. Part 2 discusses health quackery, including arthritis quackery, and mail-order "doctoring", food quackery, weight-reducing products, and how…

  7. Portable radio frequency hyperthermia instrumentation. [For heating tumor tissues in situ

    SciTech Connect

    Doss, J.D.; McCabe, C.W.

    1980-01-01

    Portable radio frequency hyperthermia instrumentation has been constructed for application in the localized heating of human and animal tumors. Tissue temperature is regulated by electronic feedback techniques. Audible and visual monitoring of tissue temperature is provided.

  8. A portable absorbed dose measuring instrument with gamma discrimination

    NASA Technical Reports Server (NTRS)

    Quam, W. M.; Wilde, W. I.

    1972-01-01

    The characteristics of an electronic instrument for measuring the radiation dose absorbed by tissues are presented. The detector is a sphere of tissue-equivalent plastic with a single wire located on a diameter of the sphere. The electronic circuits and method of operation of the detector are described. Advantages are the small size and easy portability plus ability to selectively measure neutron and gamma plus neutron events.

  9. [Portable instrument for arteriosclerosis assessment].

    PubMed

    Cao, Shuai; Chen, Xiang

    2014-01-01

    A portable instrument for arteriosclerosis assessment containing sensor module, acquisition board and embedded module was developed for home care in this paper. The sensor module consists of one ECG module and three pulse wave extraction modules, synchronously acquiring human ECG and pulse wave signal of carotid, radial, and dorsal, respectively. The acquisition board converts the sensor module's analog output signals into digital signals and transmits them to the embedded module. The embedded module realizes the functions including signal display, storage and the calculation and output of pulse wave velocity. The structure of the proposed portable instrument is simple, easy to use, and easy to expand. Small size, low cost, and low power consumption are also the advantages of this device. Experimental results demonstrated that the proposed portable instrument for arteriosclerosis assessment has high accuracy, good repeatability and can assess the degree of atherosclerosis appropriately.

  10. Freely oriented portable superconducting magnet

    DOEpatents

    Schmierer, Eric N.; Prenger, F. Coyne; Hill, Dallas D.

    2010-01-12

    A freely oriented portable superconducting magnet is disclosed. Coolant is supplied to the superconducting magnet from a repository separate from the magnet, enabling portability of the magnet. A plurality of support assemblies structurally anchor and thermally isolate the magnet within a thermal shield. A plurality of support assemblies structurally anchor and thermally isolate the thermal shield within a vacuum vessel. The support assemblies restrain movement of the magnet resulting from energizing and cooldown, as well as from changes in orientation, enabling the magnet to be freely orientable.

  11. Development of Portable Detectors

    SciTech Connect

    2006-12-01

    The purpose of this Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC (the “Contractor”) and Sense Holdings, Inc. (the “Participant”) was for the development of hand-held detectors with high sensitivity and selectivity for the detection of explosives, toxic industrial chemicals and materials, and other materials of interest for security applications. The two parties built a series of demonstration and prototype handheld sensors based upon micoelectromechanical systems (MEMS) with electronic readout.

  12. Installing Portable Classrooms With Good Air Quality.

    ERIC Educational Resources Information Center

    Godfrey, Ray

    2000-01-01

    Discusses the advantages of modular classrooms and improvements made in indoor air quality, including the pros and cons of portables, challenges districts face when planning and installing portables, and cost considerations. Concluding comments highlight system costs and maintenance required. (GR)

  13. Portable Diagnostic Radiometer.

    DTIC Science & Technology

    1985-07-01

    noise. The single-throw-double-pole switch is usually realized with an electronically- switched , latching ferrite circulator; however, at these...R2. Dl, D2 and R2 are then displayed on the liquid crystal display. The Q lines are next set to switch the latching switches into the 800 MHz...operation is basically as follows: On start- up, the CPU resets the Q line (P1-6) which sets the latching switches (see Fig. 18) to the 4 GHz radiometer

  14. Portable fluorescence meter with reference backscattering channel

    NASA Astrophysics Data System (ADS)

    Kornilin, Dmitriy V.; Grishanov, Vladimir N.; Zakharov, Valery P.; Burkov, Dmitriy S.

    2016-09-01

    Methods based on fluorescence and backscattering are intensively used for determination of the advanced glycation end products (AGE) concentration in the biological tissues. There are strong correlation between the AGE concentration and the severity of such diseases like diabetes, coronary heart disease and renal failure. This fact can be used for diagnostic purposes in medical applications. Only few investigations in this area can be useful for development of portable and affordable in vivo AGE meter because the most of them are oriented on using spectrometers. In this study we describe the design and the results of tests on volunteers of portable fluorescence meter based on two photodiodes. One channel of such fluorimeter is used for measurement of the autofluorescence (AF) intensity, another one - for the intensity of elastically scattered radiation, which can be used as a reference. This reference channel is proposed for normalization of the skin autofluorescence signal to the human skin photo type. The fluorimeter, that was developed is relatively compact and does not contain any expensive optical and electronic components. The experimental results prove that proposed tool can be used for the AGE estimation in human skin.

  15. POINTER: Portable Intelligent Trainer for External Robotics

    NASA Technical Reports Server (NTRS)

    Kuiper, Hilbert; Rikken, Patrick J.

    1994-01-01

    Intelligent tutoring systems (ITS's) play an increasing role in training and education of people with different levels of skill and knowledge. As compared to conventional computer based training (CBT) an ITS provides more tailored instruction by trying to mimic the teaching behavior of a human instructor as much as possible and is therefore much more flexible. This paper starts with an introduction to ITS's, followed by the description of an ITS for training of an (astronaut) operator in monitoring and controlling robotic arm procedures. The robotic arm will be used for exchange of equipment between a space station and a space plane involving critical and accurate movements of the robotic arm. The ITS for this application, called Pointer, is developed by TNO Physics and Electronics Laboratory and is based upon an existing ITS that includes procedural training. Pointer has been developed on a workstation whereas the target platform was a portable computer. Therefore, a lot of attention had to be paid to scaling effects and keeping up with user friendliness of the much smaller user interface. Although the learning domain was the control of a robotic arm, it is clear that use of intelligent training technologies on a portable computer has many other applications (payload operations, operation control rooms, etc.). Training can occur at any time and place in an attractive and cost effective way.

  16. Portable Pallet-Weighing Apparatus

    NASA Technical Reports Server (NTRS)

    Day, R. M.

    1983-01-01

    Portable apparatus intended for standard four-trunnion pallets readily adaptable to any large payload or other loads where shifting of cargo is to be avoided. Device lifts trunnion of pallet short distance above its resting place. Weight at trunnion applied to load cell. Similar units placed at all four trunnions.

  17. Portable Positron Measurement System (PPMS)

    SciTech Connect

    2011-01-01

    Portable Positron Measurement System (PPMS) is an automated, non-destructive inspection system based on positron annihilation, which characterizes a material's in situatomic-level properties during the manufacturing processes of formation, solidification, and heat treatment. Simultaneous manufacturing and quality monitoring now are possible. Learn more about the lab's project on our facebook site http://www.facebook.com/idahonationallaboratory.

  18. Portable Positron Measurement System (PPMS)

    ScienceCinema

    None

    2016-07-12

    Portable Positron Measurement System (PPMS) is an automated, non-destructive inspection system based on positron annihilation, which characterizes a material's in situatomic-level properties during the manufacturing processes of formation, solidification, and heat treatment. Simultaneous manufacturing and quality monitoring now are possible. Learn more about the lab's project on our facebook site http://www.facebook.com/idahonationallaboratory.

  19. Portable Liquid-Injecting System

    NASA Technical Reports Server (NTRS)

    Shuck, T.; Chin, F.; Hansen, M.

    1988-01-01

    Portable injecting-gun system dispenses predetermined amount of liquid at moderately high pressure. Tool belt holds components of liquid-injecting system. Pump and four-way valve combined in nylon housing. Connected to injecting nozzle and other components by polyvinyl tubing.

  20. Portable vacuum object handling device

    DOEpatents

    Anderson, Gordon H.

    1983-08-09

    The disclosure relates to a portable device adapted to handle objects which are not to be touched by hand. A piston and bore wall form a vacuum chamber communicating with an adaptor sealably engageable with an object to be lifted. The piston is manually moved and set to establish vacuum. A valve is manually actuatable to apply the vacuum to lift the object.

  1. Portable File Format (PFF) specifications

    SciTech Connect

    Dolan, Daniel H.

    2015-02-01

    Created at Sandia National Laboratories, the Portable File Format (PFF) allows binary data transfer across computer platforms. Although this capability is supported by many other formats, PFF files are still in use at Sandia, particularly in pulsed power research. This report provides detailed PFF specifications for accessing data without relying on legacy code.

  2. 33 CFR 149.410 - Where must portable and semi-portable fire extinguishers be located?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-portable fire extinguishers be located? 149.410 Section 149.410 Navigation and Navigable Waters COAST GUARD... and semi-portable fire extinguishers be located? All portable and semi-portable fire extinguishers described in table 149.409 must be located in the open so as to be readily seen....

  3. 33 CFR 149.410 - Where must portable and semi-portable fire extinguishers be located?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-portable fire extinguishers be located? 149.410 Section 149.410 Navigation and Navigable Waters COAST GUARD... and semi-portable fire extinguishers be located? All portable and semi-portable fire extinguishers described in table 149.409 must be located in the open so as to be readily seen....

  4. A portable hardware-in-the-loop (HIL) device for automotive diagnostic control systems.

    PubMed

    Palladino, A; Fiengo, G; Lanzo, D

    2012-01-01

    In-vehicle driving tests for evaluating the performance and diagnostic functionalities of engine control systems are often time consuming, expensive, and not reproducible. Using a hardware-in-the-loop (HIL) simulation approach, new control strategies and diagnostic functions on a controller area network (CAN) line can be easily tested in real time, in order to reduce the effort and the cost of the testing phase. Nowadays, spark ignition engines are controlled by an electronic control unit (ECU) with a large number of embedded sensors and actuators. In order to meet the rising demand of lower emissions and fuel consumption, an increasing number of control functions are added into such a unit. This work aims at presenting a portable electronic environment system, suited for HIL simulations, in order to test the engine control software and the diagnostic functionality on a CAN line, respectively, through non-regression and diagnostic tests. The performances of the proposed electronic device, called a micro hardware-in-the-loop system, are presented through the testing of the engine management system software of a 1.6 l Fiat gasoline engine with variable valve actuation for the ECU development version. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.

  5. 46 CFR 120.430 - Portable lights.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Portable lights. 120.430 Section 120.430 Shipping COAST... Systems § 120.430 Portable lights. Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the...

  6. 46 CFR 183.430 - Portable lights

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Portable lights 183.430 Section 183.430 Shipping COAST...) ELECTRICAL INSTALLATION Lighting Systems § 183.430 Portable lights Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station...

  7. 46 CFR 183.430 - Portable lights

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Portable lights 183.430 Section 183.430 Shipping COAST...) ELECTRICAL INSTALLATION Lighting Systems § 183.430 Portable lights Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station...

  8. 46 CFR 120.430 - Portable lights.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Portable lights. 120.430 Section 120.430 Shipping COAST... Systems § 120.430 Portable lights. Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the...

  9. 46 CFR 120.430 - Portable lights.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Portable lights. 120.430 Section 120.430 Shipping COAST... Systems § 120.430 Portable lights. Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the...

  10. 46 CFR 183.430 - Portable lights

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Portable lights 183.430 Section 183.430 Shipping COAST...) ELECTRICAL INSTALLATION Lighting Systems § 183.430 Portable lights Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station...

  11. 46 CFR 120.430 - Portable lights.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Portable lights. 120.430 Section 120.430 Shipping COAST... Systems § 120.430 Portable lights. Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the...

  12. 46 CFR 183.430 - Portable lights

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Portable lights 183.430 Section 183.430 Shipping COAST...) ELECTRICAL INSTALLATION Lighting Systems § 183.430 Portable lights Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station...

  13. 46 CFR 183.430 - Portable lights

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Portable lights 183.430 Section 183.430 Shipping COAST...) ELECTRICAL INSTALLATION Lighting Systems § 183.430 Portable lights Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station...

  14. 46 CFR 120.430 - Portable lights.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Portable lights. 120.430 Section 120.430 Shipping COAST... Systems § 120.430 Portable lights. Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the...

  15. 47 CFR 51.203 - Number portability.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 3 2012-10-01 2012-10-01 false Number portability. 51.203 Section 51.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) INTERCONNECTION Obligations of All Local Exchange Carriers § 51.203 Number portability. The rules governing number portability...

  16. 47 CFR 51.203 - Number portability.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 3 2013-10-01 2013-10-01 false Number portability. 51.203 Section 51.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) INTERCONNECTION Obligations of All Local Exchange Carriers § 51.203 Number portability. The rules governing number portability...

  17. 47 CFR 51.203 - Number portability.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 3 2014-10-01 2014-10-01 false Number portability. 51.203 Section 51.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) INTERCONNECTION Obligations of All Local Exchange Carriers § 51.203 Number portability. The rules governing number portability...

  18. Portable Library Support for Irregular Applications

    DTIC Science & Technology

    1995-12-01

    portable multithreading execution environment for latency hiding. The thread layer also allows the programmer to supply customized schedulers to enforce...which are code sequences that appear to execute atomically. The ber abstraction enables a portable multithreading execution environment for latency...suspension. The ber abstraction enables a portable multithreading execution environment for latency hiding. The thread layer also provides mechanisms for

  19. 47 CFR 51.203 - Number portability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Number portability. 51.203 Section 51.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) INTERCONNECTION Obligations of All Local Exchange Carriers § 51.203 Number portability. The rules governing number portability...

  20. 47 CFR 51.203 - Number portability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 3 2011-10-01 2011-10-01 false Number portability. 51.203 Section 51.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) INTERCONNECTION Obligations of All Local Exchange Carriers § 51.203 Number portability. The rules governing number portability...

  1. 48 CFR 1837.170 - Pension portability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Pension portability. 1837... ADMINISTRATION SPECIAL CATEGORIES OF CONTRACTING SERVICE CONTRACTING Service Contracts-General 1837.170 Pension portability. (a) It is NASA's policy not to require pension portability in service contracts. However, pension...

  2. Radiation detection system for portable gamma-ray spectroscopy

    DOEpatents

    Rowland, Mark S.; Howard, Douglas E.; Wong, James L.; Jessup, James L.; Bianchini, Greg M.; Miller, Wayne O.

    2006-06-20

    A portable gamma ray detection apparatus having a gamma ray detector encapsulated by a compact isolation structure having at least two volumetrically-nested enclosures where at least one is a thermal shield. The enclosures are suspension-mounted to each other to successively encapsulate the detector without structural penetrations through the thermal shields. A low power cooler is also provided capable of cooling the detector to cryogenic temperatures without consuming cryogens, due to the heat load reduction by the isolation structure and the reduction in the power requirements of the cooler. The apparatus also includes a lightweight portable power source for supplying power to the apparatus, including to the cooler and the processing means, and reducing the weight of the apparatus to enable handheld operation or toting on a user's person.

  3. Portable musical instrument amplifier

    SciTech Connect

    Christian, David E.

    1990-07-24

    The present invention relates to a musical instrument amplifier which is particularly useful for electric guitars. The amplifier has a rigid body for housing both the electronic system for amplifying and processing signals from the guitar and the system's power supply. An input plug connected to and projecting from the body is electrically coupled to the signal amplifying and processing system. When the plug is inserted into an output jack for an electric guitar, the body is rigidly carried by the guitar, and the guitar is operatively connected to the electrical amplifying and signal processing system without use of a loose interconnection cable. The amplifier is provided with an output jack, into which headphones are plugged to receive amplified signals from the guitar. By eliminating the conventional interconnection cable, the amplifier of the present invention can be used by musicians with increased flexibility and greater freedom of movement.

  4. [Advances of portable electrocardiogram monitor design].

    PubMed

    Ding, Shenping; Wang, Yinghai; Wu, Weirong; Deng, Lingli; Lu, Jidong

    2014-06-01

    Portable electrocardiogram monitor is an important equipment in the clinical diagnosis of cardiovascular diseases due to its portable, real-time features. It has a broad application and development prospects in China. In the present review, previous researches on the portable electrocardiogram monitors have been arranged, analyzed and summarized. According to the characteristics of the electrocardiogram (ECG), this paper discusses the ergonomic design of the portable electrocardiogram monitor, including hardware and software. The circuit components and software modules were parsed from the ECG features and system functions. Finally, the development trend and reference are provided for the portable electrocardiogram monitors and for the subsequent research and product design.

  5. Portable sensors for drug and explosive detection

    NASA Astrophysics Data System (ADS)

    Leginus, Joseph M.

    1994-03-01

    Westinghouse Electric is developing portable, hand-held sensors capable of detecting numerous drugs of abuse (cocaine, heroin, amphetamines) and explosives (trinitrotoluene, pentaerythritol tetranitrate, nitroglycerin). The easy-to-use system consists of a reusable electronics module and disposable probes. The sensor illuminates and detects light transmitted through optical cells of the probe during an antibody-based latex agglutination reaction. Each probe contains all the necessary reagents to carry out a test in a single step. The probe has the ability to lift minute quantities of samples from a variety of surfaces and deliver the sample to a reaction region within the device. The sensor yields a qualitative answer in 30 to 45 seconds and is able to detect illicit substances at nanogram levels.

  6. Portable bladder ultrasound: an evidence-based analysis.

    PubMed

    2006-01-01

    The aim of this review was to assess the clinical utility of portable bladder ultrasound. TARGET POPULATION AND CONDITION Data from the National Population Health Survey indicate prevalence rates of urinary incontinence are 2.5% in women and 1.4 % in men in the general population. Prevalence of urinary incontinence is higher in women than men and prevalence increases with age. Identified risk factors for urinary incontinence include female gender, increasing age, urinary tract infections (UTI), poor mobility, dementia, smoking, obesity, consuming alcohol and caffeine beverages, physical activity, pregnancy, childbirth, forceps and vacuum-assisted births, episiotomy, abdominal resection for colorectal cancer, and hormone replacement therapy. For the purposes of this review, incontinence populations will be stratified into the following; the elderly, urology patients, postoperative patients, rehabilitation settings, and neurogenic bladder populations. Urinary incontinence is defined as any involuntary leakage of urine. Incontinence can be classified into diagnostic clinical types that are useful in planning evaluation and treatment. The major types of incontinence are stress (physical exertion), urge (overactive bladder), mixed (combined urge and stress urinary incontinence), reflex (neurological impairment of the central nervous system), overflow (leakage due to full bladder), continuous (urinary tract abnormalities), congenital incontinence, and transient incontinence (temporary incontinence). Postvoid residual (PVR) urine volume, which is the amount of urine in the bladder immediately after urination, represents an important component in continence assessment and bladder management to provide quantitative feedback to the patient and continence care team regarding the effectiveness of the voiding technique. Although there is no standardized definition of normal PVR urine volume, measurements greater than 100 mL to 150 mL are considered an indication for urinary

  7. Portable liquid collection electrostatic precipitator

    DOEpatents

    Carlson, Duane C.; DeGange, John J.; Halverson, Justin E.

    2005-10-18

    A portable liquid collection electrostatic collection precipitator for analyzing air is provided which is a relatively small, self-contained device. The device has a tubular collection electrode, a reservoir for a liquid, and a pump. The pump pumps the liquid into the collection electrode such that the liquid flows down the exterior of the collection electrode and is recirculated to the reservoir. An air intake is provided such that air to be analyzed flows through an ionization section to ionize analytes in the air, and then flows near the collection electrode where ionized analytes are collected. A portable power source is connected to the air intake and the collection electrode. Ionizable constituents in the air are ionized, attracted to the collection electrode, and precipitated in the liquid. The precipitator may also have an analyzer for the liquid and may have a transceiver allowing remote operation and data collection.

  8. Portable sensor for hazardous waste

    SciTech Connect

    Piper, L.G.; Fraser, M.E.; Davis, S.J.

    1995-10-01

    We are beginning the second phase of a three and a half year program designed to develop a portable monitor for sensitive hazardous waste detection. The ultimate goal of the program is to develop our concept to the prototype instrument level. Our monitor will be a compact, portable instrument that will allow real-time, in situ, monitoring of hazardous wastes. This instrument will be able to provide the means for rapid field screening of hazardous waste sites to map the areas of greatest contamination. Remediation efforts can then focus on these areas. Further, our instrument can show whether cleanup technologies are successful at reducing hazardous materials concentrations below regulated levels, and will provide feedback to allow changes in remediation operations, if necessary, to enhance their efficacy.

  9. Microprocessor controlled portable TLD system

    NASA Technical Reports Server (NTRS)

    Apathy, I.; Deme, S.; Feher, I.

    1996-01-01

    An up-to-date microprocessor controlled thermoluminescence dosemeter (TLD) system for environmental and space dose measurements has been developed. The earlier version of the portable TLD system, Pille, was successfully used on Soviet orbital stations as well as on the US Space Shuttle, and for environmental monitoring. The new portable TLD system, Pille'95, consists of a reader and TL bulb dosemeters, and each dosemeter is provided with an EEPROM chip for automatic identification. The glow curve data are digitised and analysed by the program of the reader. The measured data and the identification number appear on the LED display of the reader. Up to several thousand measured data together with the glow curves can be stored on a removable flash memory card. The whole system is supplied either from built-in rechargeable batteries or from the mains of the space station.

  10. Portable plant health measurement system

    NASA Astrophysics Data System (ADS)

    Aksoy, Nejat

    1999-01-01

    This system is designed to assist diagnosis of the plant health globally. The system is formed by portable plant health measurement devices connected to a diagnosis and analysis center through a flexible information network. A flexible network is formed so that users from the remote areas as well as internet are able to use the system. The hardware and software is designed in an open technology for easier upgrades. Portable plant health measurement instrument is a networkable leaf flash spectrophotometer capable of measuring Qa, Electrochromy, P700, Fluorescence, S Fluorescence, reflectance spectra, temperature, humidity and image of the leaf with GPS information. The network and intelligent user interface options of the system can be used by any commercially or user designed instrument.

  11. Measurement of Ozone Emission and Particle Removal Rates from Portable Air Purifiers

    ERIC Educational Resources Information Center

    Mang, Stephen A.; Walser, Maggie L.; Nizkorodov, Sergey A.; Laux, John M.

    2009-01-01

    Portable air purifiers are popular consumer items, especially in areas with poor air quality. Unfortunately, most users of these air purifiers have minimal understanding of the factors affecting their efficiency in typical indoor settings. Emission of the air pollutant ozone (O[subscript 3]) by certain air purifiers is of particular concern. In an…

  12. Measurement of Ozone Emission and Particle Removal Rates from Portable Air Purifiers

    ERIC Educational Resources Information Center

    Mang, Stephen A.; Walser, Maggie L.; Nizkorodov, Sergey A.; Laux, John M.

    2009-01-01

    Portable air purifiers are popular consumer items, especially in areas with poor air quality. Unfortunately, most users of these air purifiers have minimal understanding of the factors affecting their efficiency in typical indoor settings. Emission of the air pollutant ozone (O[subscript 3]) by certain air purifiers is of particular concern. In an…

  13. Compact portable diffraction moire interferometer

    DOEpatents

    Deason, Vance A.; Ward, Michael B.

    1989-01-01

    A compact and portable moire interferometer used to determine surface deformations of an object. The improved interferometer is comprised of a laser beam, optical and fiber optics devices coupling the beam to one or more evanescent wave splitters, and collimating lenses directing the split beam at one or more specimen gratings. Observation means including film and video cameras may be used to view and record the resultant fringe patterns.

  14. Portable Immune-Assessment System

    NASA Technical Reports Server (NTRS)

    Pierson, Duane L.; Stowe, Raymond P.; Mishra, Saroj K.

    1995-01-01

    Portable immune-assessment system developed for use in rapidly identifying infections or contaminated environment. System combines few specific fluorescent reagents for identifying immune-cell dysfunction, toxic substances, buildup of microbial antigens or microbial growth, and potential identification of pathogenic microorganisms using fluorescent microplate reader linked to laptop computer. By using few specific dyes for cell metabolism, DNA/RNA conjugation, specific enzyme activity, or cell constituents, one makes immediate, onsite determination of person's health or of contamination of environment.

  15. Portable vacuum object handling device

    DOEpatents

    Anderson, G.H.

    1983-08-09

    The disclosure relates to a portable device adapted to handle objects which are not to be touched by hand. A piston and bore wall form a vacuum chamber communicating with an adaptor sealably engageable with an object to be lifted. The piston is manually moved and set to establish vacuum. A valve is manually actuatable to apply the vacuum to lift the object. 1 fig.

  16. Apollo Portable Life Support System

    NASA Image and Video Library

    1968-06-11

    S68-34580 (1968) --- With its exterior removed, the Apollo portable life support system (PLSS) can be easily studied. The PLSS is worn as a backpack over the Extravehicular Mobility Unit (EMU), a multi-layered spacesuit used for outside-the-spacecraft activity. JSC photographic frame no. S68-34582 is a close-up view of the working parts of the PLSS.

  17. Apollo Portable Life Support System

    NASA Image and Video Library

    1968-06-11

    S68-34582 (1968) --- With its exterior removed, the Apollo portable life support system (PLSS) can be easily studied. The PLSS is worn as a backpack over the Extravehicular Mobility Unit (EMU) a multi-layered spacesuit used for outside-the-spacecraft activity. JSC photographic frame no. S68-34582 is a wider view of the exposed interior working parts of the PLSS and its removed cover.

  18. Portable telepathology: methods and tools.

    PubMed

    Alfaro, Luis; Roca, Ma José

    2008-07-15

    Telepathology is becoming easier to implement in most pathology departments. In fact e-mail image transmit can be done from almost any pathologist as a simplistic telepathology system. We tried to develop a way to improve capabilities of communication among pathologists with the idea that the system should be affordable for everybody. We took the premise that any pathology department would have microscopes and computers with Internet connection, and selected a few elements to convert them into a telepathology station. Needs were reduced to a camera to collect images, a universal microscope adapter for the camera, a device to connect the camera to the computer, and a software for the remote image transmit. We found out a microscope adapter (MaxView Plus) that allowed us connect almost any domestic digital camera to any microscope. The video out signal from the camera was sent to the computer through an Aver Media USB connector. At last, we selected a group of portable applications that were assembled into a USB memory device. Portable applications are computer programs that can be carried generally on USB flash drives, but also in any other portable device, and used on any (Windows) computer without installation. Besides, when unplugging the device, none of personal data is left behind. We selected open-source applications, and based the pathology image transmission to VLC Media Player due to its functionality as streaming server, portability and ease of use and configuration. Audio transmission was usually done through normal phone lines. We also employed alternative videoconferencing software, SightSpeed for bi-directional image transmission from microscopes, and conventional cameras allowing visual communication and also image transmit from gross pathology specimens. All these elements allowed us to install and use a telepathology system in a few minutes, fully prepared for real time image broadcast.

  19. Compact portable diffraction moire interferometer

    DOEpatents

    Deason, V.A.; Ward, M.B.

    1988-05-23

    A compact and portable moire interferometer used to determine surface deformations of an object. The improved interferometer is comprised of a laser beam, optical and fiber optics devices coupling the beam to one or more evanescent wave splitters, and collimating lenses directing the split beam at one or more specimen gratings. Observations means including film and video cameras may be used to view and record the resultant fringe patterns. 7 figs.

  20. Software Complexity Threatens Performance Portability

    SciTech Connect

    Gamblin, T.

    2015-09-11

    Modern HPC software packages are rarely self-contained. They depend on a large number of external libraries, and many spend large fractions of their runtime in external subroutines. Performance portability depends not only on the effort of application teams, but also on the availability of well-tuned libraries. At most sites, the burden of maintaining libraries is shared by code teams and facilities. Facilities typically provide well-tuned default versions, but code teams frequently build with bleeding-edge compilers to achieve high performance. For this reason, HPC has no “standard” software stack, unlike other domains where performance is not critical. Incompatibilities among compilers and software versions force application teams and facility staff to re-build custom versions of libraries for each new toolchain. Because the number of potential configurations is combinatorial, and because HPC software is notoriously difficult to port to new machines [3, 7, 8], the tuning effort required to support and maintain performance-portable libraries outstrips the available manpower at most sites. Software complexity is a growing obstacle to performance portability for HPC.

  1. PORTABLE ACOUSTIC MONITORING PACKAGE (PAMP)

    SciTech Connect

    John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Patrick Browning

    2004-07-20

    The Portable Acoustic Monitoring Package (PAMP) has been designed to record and monitor the acoustic signal in natural gas transmission lines. In particular the three acoustic signals associated with a line leak. The system is portable ({approx}30 lbs) and is designed for line pressures up to 1000 psi. It has become apparent that cataloging of the various background acoustic signals in natural gas transmission line is very important if a system to identify leak signals is to be developed. The low-pressure (0-200 psig) laboratory test phase has been completed and a number of field trials have been conducted. Before the cataloging phase could begin, a few problems identified in field trials identified had to be corrected such as: (1) Decreased microphone sensitivity at line pressures above 250 psig. (2) The inability to deal with large data sets collected when cataloging the variety of signals in a transmission line. (3) The lack of an available online acoustic calibration system. These problems have been solved and the WVU PAMP is now fully functional over the entire pressure range found in the Natural Gas transmission lines in this region. Field portability and reliability have been greatly improved. Data collection and storage have also improved to the point were the full acoustic spectrum of acoustic signals can be accurately cataloged, recorded and described.

  2. Design of portable electric and magnetic field generators

    NASA Astrophysics Data System (ADS)

    Stewart, M. G.; Siew, W. H.; Campbell, L. C.; Stewart, M. G.; Siew, W. H.

    2000-11-01

    Electric and magnetic field generators capable of producing high-amplitude output are not readily available. This presents difficulties for electromagnetic compatibility testing of new measurement systems where these systems are intended to operate in a particularly hostile electromagnetic environment. A portable electric and a portable magnetic field generator having high pulsed field output are described in this paper. The output of these generators were determined using an electromagnetic-compatible measurement system. These generators allow immunity testing in the laboratory of electronic systems to very high electrical fields, as well as for functional verification of the electronic systems on site. In the longer term, the basic design of the magnetic field generator may be developed as the generator to provide the damped sinusoid magnetic field specified in IEC 61000-4-10, which is adopted in BS EN 61000-4-10.

  3. Performance and long term degradation of 7 W micro-tubular solid oxide fuel cells for portable applications

    NASA Astrophysics Data System (ADS)

    Torrell, M.; Morata, A.; Kayser, P.; Kendall, M.; Kendall, K.; Tarancón, A.

    2015-07-01

    Micro-tubular SOFCs have shown an astonishing thermal shock resistance, many orders of magnitude larger than planar SOFCs, opening the possibility of being used in portable applications. However, only few studies have been devoted to study the degradation of large-area micro-tubular SOFCs. This work presents microstructural, electrochemical and long term degradation studies of single micro-tubular cells fabricated by high shear extrusion, operating in the intermediate range of temperatures (T∼700 °C). A maximum power of 7 W per cell has been measured in a wide range of fuel utilizations between 10% and 60% at 700 °C. A degradation rate of 360 mW/1000 h (8%) has been observed for cells operated over more than 1500 h under fuel utilizations of 40%. Higher fuel utilizations lead to strong degradations associated to nickel oxidation/reduction processes. Quick thermal cycling with heating ramp rates of 30 °C /min yielded degradation rates of 440 mW/100 cycles (9%). These reasonable values of degradation under continuous and thermal cycling operation approach the requirements for many portable applications including auxiliary power units or consumer electronics opening this typically forbidden market to the SOFC technology.

  4. Portable microcoil NMR detection coupled to capillary electrophoresis.

    PubMed

    Diekmann, Joana; Adams, Kristl L; Klunder, Gregory L; Evans, Lee; Steele, Paul; Vogt, Carla; Herberg, Julie L

    2011-02-15

    High-efficiency separation techniques, such as capillary electrophoresis (CE), coupled to a nondestructive nuclear magnetic resonance (NMR) spectrometer offer the ability to separate, chemically identify, and provide structural information on analytes in small sample volumes. Previous CE-NMR coupled systems utilized laboratory-scale NMR magnets and spectrometers, which require very long separation capillaries. New technological developments in electronics have reduced the size of the NMR system, and small 1-2 T permanent magnets provide the possibilities of a truly portable NMR. The microcoils used in portable and laboratory-scale NMR may offer the advantage of improved mass sensitivity because the limit of detection (LOD) is proportional to the coil diameter. In this work, CE is coupled with a portable, briefcase-sized NMR system that incorporates a microcoil probe and a 1.8 T permanent magnet to measure (19)F NMR spectra. Separations of fluorinated molecules are demonstrated with stopped- and continuous-flow NMR detection. The results demonstrate that coupling CE to a portable NMR instrument is feasible and can provide a low-cost method to obtain structural information on microliter samples. An LOD of 31.8 nmol for perfluorotributylamine with a resolution of 4 ppm has been achieved with this system.

  5. DNA-Assisted β-phase Nucleation and Alignment of Molecular Dipoles in PVDF Film: A Realization of Self-Poled Bioinspired Flexible Polymer Nanogenerator for Portable Electronic Devices.

    PubMed

    Tamang, Abiral; Ghosh, Sujoy Kumar; Garain, Samiran; Alam, Md Mehebub; Haeberle, Jörg; Henkel, Karsten; Schmeisser, Dieter; Mandal, Dipankar

    2015-08-05

    A flexible nanogenerator (NG) is fabricated with a poly(vinylidene fluoride) (PVDF) film, where deoxyribonucleic acid (DNA) is the agent for the electroactive β-phase nucleation. Denatured DNA is co-operating to align the molecular -CH2/-CF2 dipoles of PVDF causing piezoelectricity without electrical poling. The NG is capable of harvesting energy from a variety of easily accessible mechanical stress such as human touch, machine vibration, football juggling, and walking. The NG exhibits high piezoelectric energy conversion efficiency facilitating the instant turn-on of several green or blue light-emitting diodes. The generated energy can be used to charge capacitors providing a wide scope for the design of self-powered portable devices.

  6. Fuel cell systems for personal and portable power applications

    SciTech Connect

    Fateen, S. A.

    2001-01-01

    Fuel cells are devices that electrochemically convert fuel, usually hydrogen gas, to directly produce electricity. Fuel cells were initially developed for use in the space program to provide electricity and drinking water for astronauts. Fuel cells are under development for use in the automobile industry to power cars and buses with the advantage of lower emissions and higher efficiency than internal combustion engines. Fuel cells also have great potential to be used in portable consumer products like cellular phones and laptop computers, as well as military applications. In fact, any products that use batteries can be powered by fuel cells. In this project, we examine fuel cell system trade-offs between fuel cell type and energy storage/hydrogen production for portable power generation. The types of fuel cells being examined include stored hydrogen PEM (polymer electrolyte), direct methanol fuel cells (DMFC) and indirect methanol fuel cells, where methanol is reformed producing hydrogen. These fuel cells systems can operate at or near ambient conditions, which make them potentially optimal for use in manned personal power applications. The expected power production for these systems is in the range of milliwatts to 500 watts of electrical power for either personal or soldier field use. The fuel cell system trade-offs examine hydrogen storage by metal hydrides, carbon nanotubes, and compressed hydrogen tanks. We examine the weights each system, volume, fuel storage, system costs, system peripherals, power output, and fuel cell feasibility in portable devices.

  7. Multimedia architectures: from desktop systems to portable appliances

    NASA Astrophysics Data System (ADS)

    Bhaskaran, Vasudev; Konstantinides, Konstantinos; Natarajan, Balas R.

    1997-01-01

    Future desktop and portable computing systems will have as their core an integrated multimedia system. Such a system will seamlessly combine digital video, digital audio, computer animation, text, and graphics. Furthermore, such a system will allow for mixed-media creation, dissemination, and interactive access in real time. Multimedia architectures that need to support these functions have traditionally required special display and processing units for the different media types. This approach tends to be expensive and is inefficient in its use of silicon. Furthermore, such media-specific processing units are unable to cope with the fluid nature of the multimedia market wherein the needs and standards are changing and system manufacturers may demand a single component media engine across a range of products. This constraint has led to a shift towards providing a single-component multimedia specific computing engine that can be integrated easily within desktop systems, tethered consumer appliances, or portable appliances. In this paper, we review some of the recent architectural efforts in developing integrated media systems. We primarily focus on two efforts, namely the evolution of multimedia-capable general purpose processors and a more recent effort in developing single component mixed media co-processors. Design considerations that could facilitate the migration of these technologies to a portable integrated media system also are presented.

  8. Disposable cartridge biosensor platform for portable diagnostics

    NASA Astrophysics Data System (ADS)

    Yaras, Yusuf S.; Cakmak, Onur; Gunduz, Ali B.; Saglam, Gokhan; Olcer, Selim; Mostafazadeh, Aref; Baris, Ibrahim; Civitci, Fehmi; Yaralioglu, Goksen G.; Urey, Hakan

    2017-03-01

    We developed two types of cantilever-based biosensors for portable diagnostics applications. One sensor is based on MEMS cantilever chip mounted in a microfluidic channel and the other sensor is based on a movable optical fiber placed across a microfluidic channel. Both types of sensors were aimed at direct mechanical measurement of coagulation time in a disposable cartridge using plasma or whole blood samples. There are several similarities and also some important differences between the MEMS based and the optical fiber based solutions. The aim of this paper is to provide a comparison between the two solutions and the results. For both types of sensors, actuation of the cantilever or the moving fiber is achieved using an electro coil and the readout is optical. Since both the actuation and sensing are remote, no electrical connections are required for the cartridge. Therefore it is possible to build low cost disposable cartridges. The reader unit for the cartridge contains light sources, photodetectors, the electro coil, a heater, analog electronics, and a microprocessor. The reader unit has different optical interfaces for the cartridges that have MEMS cantilevers and moving fibers. MEMS based platform has better sensitivity but optomechanical alignment is a challenge and measurements with whole blood were not possible due to high scattering of light by the red blood cells. Fiber sensor based platform has relaxed optomechanical tolerances, ease of manufacturing, and it allows measurements in whole blood. Both sensors were tested using control plasma samples for activated-Partial-Thromboplastin-Time (aPTT) measurements. Control plasma test results matched with the manufacturer's datasheet. Optical fiber based system was tested for aPTT tests with human whole blood samples and the proposed platform provided repeatable test results making the system method of choice for portable diagnostics.

  9. Opportunities for portable Ballard Fuel Cells

    SciTech Connect

    Voss, H.H.; Huff, J.R.

    1996-12-31

    With the increasing proliferation and sophistication of portable electronic devices in both commercial and military markets, the need has arisen for small, lightweight power supplies that can provide increased operating life over those presently available. A solution to this power problem is the development of portable Ballard Fuel Cell power systems that operate with a hydrogen fuel source and air. Ballard has developed PEM fuel cell stacks and power systems in the 25 to 100 watt range for both of these markets. For military use, Ballard has teamed with Ball Corporation and Hydrogen Consultants, Inc. and has provided the Ballard Fuel Cell stack for an ambient PEM fuel cell power system for the DoD. The system provides power from idle to I 00 watts and has the capability of delivering overloads of 125 watts for short periods of time. The system is designed to operate over a wide range of temperature, relative humidity and altitude. Hydrogen is supplied as a compressed gas, metal hydride or chemical hydride packaged in a unit that is mated to the power/control unit. The hydrogen sources provide 1.5, 5 and 15 kWh of operation, respectively. The design of the fuel cell power system enables the unit to operate at 12 volts or 24 volts depending upon the equipment being used. For commercial applications, as with the military, fuel cell power sources in the 25 to 500 watt range will be competing with advanced batteries. Ambient PEM fuel cell designs and demonstrators are being developed at 25 watts and other low power levels. Goals are minimum stack volume and weight and greatly enhanced operating life with reasonable system weight and volume. This paper will discuss ambient PEM fuel cell designs and performance and operating parameters for a number of power levels in the multiwatt range.

  10. Portable sensor for hazardous waste

    SciTech Connect

    Piper, L.G.; Hunter, A.J.R.; Fraser, M.E.; Davis, S.J.

    1996-12-31

    We are part-way through the second phase of a 4-year program designed to develop a portable monitor for sensitive hazardous waste detection. The ultimate goal of the program is to develop our concept to the prototype instrument level. Our monitor will be a compact, portable instrument that will allow real-time, in situ, monitoring of hazardous wastes. This instrument will be able to provide the means for rapid field screening of hazardous waste sites to map the areas of greatest contamination. Remediation efforts can then focus on these areas. Our analysis approach is to excite atomic and molecular fluorescence by the technique of active nitrogen energy transfer (ANET). The active nitrogen is made in a dielectric-barrier (D-B) discharge in nitrogen at atmospheric pressure. Only a few emission lines or bands are excited for each hazardous species, so spectral resolution requirements are greatly simplified over those of other spectroscopic techniques. The D-B discharge is compact, 1 to 2 cm in diameter and 1 to 10 cm long. Furthermore, the discharge power requirements are quite modest, so that the unit can be powered by batteries. Thus an instrument based on ANET can readily be made portable. Our results indicate that ANET is a very sensitive technique for monitoring heavy metals and chlorinated hydrocarbons. We have demonstrated an overall detection sensitivity for most species that is at or below ppb levels. ANET alone, however, appears to be most successful in treating hazardous species that have been atomized. We are therefore developing a hybrid technique which combines a miniature, solid-state laser for sample collection and vaporization with ANET for subsequent detection. This approach requires no special sample preparation, can operate continuously, and lends itself well to compact packaging.

  11. 75 FR 5013 - Local Number Portability Porting Interval and Validation Requirements; Telephone Number Portability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-01

    ... From the Federal Register Online via the Government Publishing Office FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 52 Local Number Portability Porting Interval and Validation Requirements; Telephone Number Portability AGENCY: Federal Communications Commission. ACTION: Proposed rule. SUMMARY: The...

  12. Detection of adulterants in honey using a portable Raman Spectrometer

    NASA Astrophysics Data System (ADS)

    Garcia, Kenneth Leigh

    Food adulteration is a growing problem worldwide. In the United States over half of honey consumed is provided with imported products as total domestic production of honey is unable to meet the demand. As pure, natural honey is a labor intensive, relatively expensive product it is a prime target for adulteration with less expensive sweeteners. Previously published work describes the detection of these adulterants in a strict laboratory environment with time consuming techniques and delicate instrumentation. Experiments confirm that adulterants such as high fructose corn syrup and rice malt syrup can be detected in honey using Raman Spectroscopy and portable equipment. When laser light is applied to the products, the result is a Raman signal of inelastically scattered photons representing the fingerprints of the various molecules. When this signal is detected and stored in a laptop computer it can be analyzed for characteristics peculiar to honey and to the adulterants.

  13. Portable punch and die jig

    DOEpatents

    Lewandowski, Edward F.; Anderson, Petrus A.

    1978-01-01

    A portable punch and die jig includes a U-shaped jig of predetermined width having a slot of predetermined width in the base thereof extending completely across the width of the jig adapted to fit over the walls of rectangular tubes and a punch and die assembly disposed in a hole extending through the base of the jig communicating with the slot in the base of the jig for punching a hole in the walls of the rectangular tubes at precisely determined locations.

  14. Portable X-Ray Device

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Portable x-ray instrument developed by NASA now being produced commercially as an industrial tool may soon find further utility as a medical system. The instrument is Lixiscope - Low Intensity X-Ray Imaging Scope -- a self-contained, battery-powered fluoroscope that produces an instant image through use of a small amount of radioactive isotope. Originally developed by Goddard Space Flight Center, Lixiscope is now being produced by Lixi, Inc. which has an exclusive NASA license for one version of the device.

  15. Portable receiver for radar detection

    DOEpatents

    Lopes, Christopher D.; Kotter, Dale K.

    2008-10-14

    Various embodiments are described relating to a portable antenna-equipped device for multi-band radar detection. The detection device includes a plurality of antennas on a flexible substrate, a detection-and-control circuit, an indicator and a power source. The antenna may include one or more planar lithographic antennas that may be fabricated on a thin-film substrate. Each antenna may be tuned to a different selection frequency or band. The antennas may include a bolometer for radar detection. Each antenna may include a frequency selective surface for tuning to the selection frequency.

  16. Portable smartphone optical fibre spectrometer

    NASA Astrophysics Data System (ADS)

    Hossain, Md. Arafat; Canning, John; Cook, Kevin; Jamalipour, Abbas

    2015-09-01

    A low cost, optical fibre based spectrometer has been developed on a smartphone platform for field-portable spectral analysis. Light of visible wavelength is collected using a multimode optical fibre and diffracted by a low cost nanoimprinted diffraction grating. A measurement range over 300 nm span (λ = 400 to 700 nm) is obtained using the smartphone CMOS chip. The spectral resolution is Δλ ~ 0.42 nm/screen pixel. A customized Android application processed the spectra on the same platform and shares with other devices. The results compare well with commercially available spectrometer.

  17. Portable Ethylene Oxide Sterilization Chamber

    PubMed Central

    Songer, J. R.; Mathis, R. G.

    1969-01-01

    A portable ethylene oxide sterilization chamber was designed, constructed, and tested for use in the sterilization of embolectomy catheters. The unit can accommodate catheters up to 40 inches (101.6 cm) in length and can be operated for less than 4 cents per cycle. A constant concentration of 500 mg of ethylene oxide per liter of space and holding periods of 4 and 6 hr at 43 and 22 C, respectively, were adequate when tested with B. subtilis spores. The estimated cost of construction was $165.00. If temperature control is unnecessary, the cost is approximately $80.00. Images PMID:4977644

  18. Improved Portable Ultrasonic Leak Detectors

    NASA Technical Reports Server (NTRS)

    Youngquist, Robert C.; Moerk, John S.; Haskell, William D.; Cox, Robert B.; Polk, Jimmy D.; Strobel, James P.; Luaces, Frank

    1995-01-01

    Improved portable ultrasonic leak detector features three interchangeable ultrasonic-transducer modules, each suited for operation in unique noncontact or contact mode. One module equipped with ultrasound-collecting horn for use in scanning to detect leaks from distance; horn provides directional sensitivity pattern with sensitivity multiplied by factor of about 6 in forward direction. Another module similar, does not include horn; this module used for scanning close to suspected leak, where proximity of leak more than offsets loss of sensitivity occasioned by lack of horn. Third module designed to be pressed against leaking vessel; includes rugged stainless-steel shell. Improved detectors perform significantly better, smaller, more rugged, and greater sensitivity.

  19. Open Component Portability Infrastructure (OPENCPI)

    DTIC Science & Technology

    2009-11-01

    AFRL-RI-RS-TR-2009-257 Final Technical Report November 2009 OPEN COMPONENT PORTABILITY INFRASTRUCTURE (OPENCPI) Mercury ...ORGANIZATION NAME(S) AND ADDRESS(ES) Mercury Federal Systems, Inc. 1901 South Bell Street, Suite 402 Arlington, VA 22202-4511 8. PERFORMING ORGANIZATION...APPLICATIONS  30  6.0  REFERENCES  31  7.0  LIST OF ABBRVIATIONS AND ACRONYMS  32  APPENDIX A: ADDITIONAL REFERENCES  34  APPENDIX B:  MERCURY  CPI ITAR

  20. Microbial fuel cells as discontinuous portable power sources: syntropic interactions with anode-respiring bacteria.

    PubMed

    Gao, Yaohuan; An, Junyeong; Ryu, Hodon; Lee, Hyung-Sool

    2014-04-01

    For microbial fuel cells (MFCs) to work as portable power sources used in a discontinuous manner, anode-respiring bacteria (ARB) should survive for at least several days in the absence of exogenous electron donors, and immediately generate current upon addition of an electron donor. Here, we proved that biopolymer-accumulating bacteria provide substrate (fuel) for ARB to generate current in lack of exogenous electron donor in 4 days, which allows MFCs to be used as portable power sources. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. 46 CFR 119.458 - Portable fuel systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Portable fuel systems. 119.458 Section 119.458 Shipping... Machinery Requirements § 119.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where used for portable dewatering...

  2. 46 CFR 119.458 - Portable fuel systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Portable fuel systems. 119.458 Section 119.458 Shipping... Machinery Requirements § 119.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where used for portable dewatering pumps...

  3. 46 CFR 119.458 - Portable fuel systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Portable fuel systems. 119.458 Section 119.458 Shipping... Machinery Requirements § 119.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where used for portable dewatering pumps...

  4. 49 CFR 180.603 - Qualification of portable tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... (CSC). (e) Exemption portable tanks based on DOT 51 portable tanks. The owner of a portable tank... conformance with the requirements for Specification DOT 51 portable tanks with the exception of the location... number). During the period the portable tank is in service, and for one year thereafter, the owner of...

  5. An OSEE Based Portable Surface Contamination Monitor

    NASA Technical Reports Server (NTRS)

    Perey, Daniel F.

    1997-01-01

    Many industrial and aerospace processes involving the joining of materials, require sufficient surface cleanliness to insure proper bonding. Processes as diverse as painting, welding, or the soldering of electronic circuits will be compromised if prior inspection and removal of surface contaminants is inadequate. As process requirements become more stringent and the number of different materials and identified contaminants increases, various instruments and techniques have been developed for improved inspection. One such technique based on the principle of Optically Stimulated Electron Emission (OSEE) has been explored for a number of years as a tool for surface contamination monitoring. Some of the benefits of OSEE are: it's non-contacting; requires little operator training; and has very high contamination sensitivity. This paper describes the development of a portable OSEE based surface contamination monitor. The instrument is suitable for both hand-held and robotic inspections with either manual or automated control of instrument operation. In addition, instrument output data is visually displayed to the operator and may be output to an external computer for archiving or analysis.

  6. 33 CFR 145.01 - Portable and semi-portable fire extinguishers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Portable and semi-portable fire extinguishers. 145.01 Section 145.01 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES FIRE-FIGHTING EQUIPMENT § 145.01 Portable and...

  7. 33 CFR 145.01 - Portable and semi-portable fire extinguishers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Portable and semi-portable fire extinguishers. 145.01 Section 145.01 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES FIRE-FIGHTING EQUIPMENT § 145.01 Portable and...

  8. 33 CFR 145.01 - Portable and semi-portable fire extinguishers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Portable and semi-portable fire extinguishers. 145.01 Section 145.01 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES FIRE-FIGHTING EQUIPMENT § 145.01 Portable and...

  9. 33 CFR 145.01 - Portable and semi-portable fire extinguishers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Portable and semi-portable fire extinguishers. 145.01 Section 145.01 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES FIRE-FIGHTING EQUIPMENT § 145.01 Portable and...

  10. 33 CFR 145.01 - Portable and semi-portable fire extinguishers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Portable and semi-portable fire extinguishers. 145.01 Section 145.01 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES FIRE-FIGHTING EQUIPMENT § 145.01 Portable and...

  11. Life cycle assessment of post-consumer plastics production from waste electrical and electronic equipment (WEEE) treatment residues in a Central European plastics recycling plant.

    PubMed

    Wäger, Patrick A; Hischier, Roland

    2015-10-01

    Plastics play an increasingly important role in reaching the recovery and recycling rates defined in the European WEEE Directive. In a recent study we have determined the life cycle environmental impacts of post-consumer plastics production from mixed, plastics-rich WEEE treatment residues in the Central European plant of a market-leading plastics recycler, both from the perspective of the customers delivering the residues and the customers buying the obtained post-consumer recycled plastics. The results of our life cycle assessments, which were extensively tested with sensitivity analyses, show that from both perspectives plastics recycling is clearly superior to the alternatives considered in this study (i.e. municipal solid waste incineration (MSWI) and virgin plastics production). For the three ReCiPe endpoint damage categories, incineration in an MSWI plant results in an impact exceeding that of the examined plastics recycling facility each by about a factor of 4, and the production of virgin plastics has an impact exceeding that of the post-consumer recycled (PCR) plastics production each by a factor of 6-10. On a midpoint indicator level the picture is more differentiated, showing that the environmental impacts of the recycling options are lower by 50% and more for almost all impact factors. While this provides the necessary evidence for the environmental benefits of plastics recycling compared to existing alternatives, it can, however, not be taken as conclusive evidence. To be conclusive, future research will have to address the fate of hazardous substances in the outputs of such recycling systems in more detail. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. a Portable Pulsed Neutron Generator

    NASA Astrophysics Data System (ADS)

    Skoulakis, A.; Androulakis, G. C.; Clark, E. L.; Hassan, S. M.; Lee, P.; Chatzakis, J.; Bakarezos, M.; Dimitriou, V.; Petridis, C.; Papadogiannis, N. A.; Tatarakis, M.

    2014-02-01

    The design and construction of a pulsed plasma focus device to be used as a portable neutron source for material analysis such as explosive detection using gamma spectroscopy is presented. The device is capable of operating at a repetitive rate of a few Hz. When deuterium gas is used, up to 105 neutrons per shot are expected to be produced with a temporal pulse width of a few tens of nanoseconds. The pulsed operation of the device and its portable size are its main advantage in comparison with the existing continuous neutron sources. Parts of the device include the electrical charging unit, the capacitor bank, the spark switch (spark gap), the trigger unit and the vacuum-fuel chamber / anode-cathode. Numerical simulations are used for the simulation of the electrical characteristics of the device including the scaling of the capacitor bank energies with total current, the pinch current, and the scaling of neutron yields with energies and currents. The MCNPX code is used to simulate the moderation of the produced neutrons in a simplified geometry and subsequently, the interaction of thermal neutrons with a test target and the corresponding prompt γ-ray generation.

  13. Portable Health Algorithms Test System

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin J.; Wong, Edmond; Fulton, Christopher E.; Sowers, Thomas S.; Maul, William A.

    2010-01-01

    A document discusses the Portable Health Algorithms Test (PHALT) System, which has been designed as a means for evolving the maturity and credibility of algorithms developed to assess the health of aerospace systems. Comprising an integrated hardware-software environment, the PHALT system allows systems health management algorithms to be developed in a graphical programming environment, to be tested and refined using system simulation or test data playback, and to be evaluated in a real-time hardware-in-the-loop mode with a live test article. The integrated hardware and software development environment provides a seamless transition from algorithm development to real-time implementation. The portability of the hardware makes it quick and easy to transport between test facilities. This hard ware/software architecture is flexible enough to support a variety of diagnostic applications and test hardware, and the GUI-based rapid prototyping capability is sufficient to support development execution, and testing of custom diagnostic algorithms. The PHALT operating system supports execution of diagnostic algorithms under real-time constraints. PHALT can perform real-time capture and playback of test rig data with the ability to augment/ modify the data stream (e.g. inject simulated faults). It performs algorithm testing using a variety of data input sources, including real-time data acquisition, test data playback, and system simulations, and also provides system feedback to evaluate closed-loop diagnostic response and mitigation control.

  14. A portable accelerator control toolkit

    SciTech Connect

    Watson, W.A. III

    1997-06-01

    In recent years, the expense of creating good control software has led to a number of collaborative efforts among laboratories to share this cost. The EPICS collaboration is a particularly successful example of this trend. More recently another collaborative effort has addressed the need for sophisticated high level software, including model driven accelerator controls. This work builds upon the CDEV (Common DEVice) software framework, which provides a generic abstraction of a control system, and maps that abstraction onto a number of site-specific control systems including EPICS, the SLAC control system, CERN/PS and others. In principle, it is now possible to create portable accelerator control applications which have no knowledge of the underlying and site-specific control system. Applications based on CDEV now provide a growing suite of tools for accelerator operations, including general purpose displays, an on-line accelerator model, beamline steering, machine status displays incorporating both hardware and model information (such as beam positions overlaid with beta functions) and more. A survey of CDEV compatible portable applications will be presented, as well as plans for future development.

  15. Portable Diagnostics and Rapid Germination

    SciTech Connect

    Dunn, Zachary Spencer

    2016-12-01

    In the Bioenergy and Defense Department of Sandia National Laboratories, characterization of the BaDx (Bacillus anthracis diagnostic cartridge) was performed and rapid germination chemistry was investigated. BaDx was tested with complex sample matrixes inoculated with Bacillus anthracis, and the trials proved that BaDx will detect Bacillus anthracis in a variety of the medium, such as dirt, serum, blood, milk, and horse fluids. The dimensions of the device were altered to accommodate an E. coli or Listeria lateral flow immunoassay, and using a laser printer, BaDx devices were manufactured to identify E. coli and Listeria. Initial testing with E. coli versions of BaDx indicate that the device will be viable as a portable diagnostic cartridge. The device would be more effective with faster bacteria germination; hence studies were performed the use of rapid germination chemistry. Trials with calcium dipicolinic acid displayed increased cell germination, as shown by control studies using a microplate reader. Upon lyophilization the rapid germination chemistry failed to change growth patterns, indicating that the calcium dipicolinic acid was not solubilized under the conditions tested. Although incompatible with the portable diagnostic device, the experiments proved that the rapid germination chemistry was effective in increasing cell germination.

  16. 46 CFR 25.30-10 - Hand-portable fire extinguishers and semi-portable fire-extinguishing systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Hand-portable fire extinguishers and semi-portable fire... UNINSPECTED VESSELS REQUIREMENTS Fire Extinguishing Equipment § 25.30-10 Hand-portable fire extinguishers and semi-portable fire-extinguishing systems. (a) Hand portable fire extinguishers and semiportable...

  17. 46 CFR 25.30-10 - Hand-portable fire extinguishers and semi-portable fire-extinguishing systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Hand-portable fire extinguishers and semi-portable fire... UNINSPECTED VESSELS REQUIREMENTS Fire Extinguishing Equipment § 25.30-10 Hand-portable fire extinguishers and semi-portable fire-extinguishing systems. (a) Hand portable fire extinguishers and semiportable...

  18. 46 CFR 25.30-10 - Hand-portable fire extinguishers and semi-portable fire-extinguishing systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Hand-portable fire extinguishers and semi-portable fire... UNINSPECTED VESSELS REQUIREMENTS Fire Extinguishing Equipment § 25.30-10 Hand-portable fire extinguishers and semi-portable fire-extinguishing systems. (a) Hand portable fire extinguishers and semiportable...

  19. 46 CFR 25.30-10 - Hand-portable fire extinguishers and semi-portable fire-extinguishing systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Hand-portable fire extinguishers and semi-portable fire... UNINSPECTED VESSELS REQUIREMENTS Fire Extinguishing Equipment § 25.30-10 Hand-portable fire extinguishers and semi-portable fire-extinguishing systems. (a) Hand portable fire extinguishers and semiportable...

  20. 46 CFR 25.30-10 - Hand-portable fire extinguishers and semi-portable fire-extinguishing systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Hand-portable fire extinguishers and semi-portable fire... UNINSPECTED VESSELS REQUIREMENTS Fire Extinguishing Equipment § 25.30-10 Hand-portable fire extinguishers and semi-portable fire-extinguishing systems. (a) Hand portable fire extinguishers and semiportable...

  1. Experimental evaluation of a portable powered ankle-foot orthosis.

    PubMed

    Shorter, Kenneth A; Li, Yifan; Morris, Emily A; Kogler, Géza F; Hsiao-Wecksler, Elizabeth T

    2011-01-01

    Ankle-foot orthoses (AFOs) ameliorate the impact of impairments to the lower limb neuromuscular motor system that affect gait. Emerging technologies provide a vision for fully powered, untethered AFOs. The portable powered AFO (PPAFO) provides both plantarflexor and dorsiflexor torque assistance via a bi-directional pneumatic rotary actuator. The system uses a portable pneumatic power source (bottle of compressed CO(2)) and embedded electronics to control foot motion during level walking. Experimental data were collected to demonstrate functionality from two subjects with bilateral impairments to the lower legs. These data demonstrated the PPAFO's ability to provide functional assistance during gait. The stringent design requirements of light weight, small size, high efficiency and low noise make the creation of daily wear assist devices challenging; but once such devices appear, they will present new opportunities for clinical treatment of gait abnormalities.

  2. Guidelines for Consumer Education.

    ERIC Educational Resources Information Center

    Illinois State Office of the Superintendent of Public Instruction, Springfield.

    Consumer Education is not intended to direct consumer choices. It does provide an awareness of alternatives and opportunities and assists the consumer in making the choice which is best for his purposes in light of his values. It is not the purpose of consumer education to indoctrinate values. Consumer education should provide the experiences that…

  3. 46 CFR 129.450 - Portable lighting.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Portable lighting. 129.450 Section 129.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Lighting Systems § 129.450 Portable lighting. Each vessel must be equipped with at least two...

  4. 46 CFR 129.450 - Portable lighting.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Portable lighting. 129.450 Section 129.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Lighting Systems § 129.450 Portable lighting. Each vessel must be equipped with at least two...

  5. 46 CFR 129.450 - Portable lighting.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Portable lighting. 129.450 Section 129.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Lighting Systems § 129.450 Portable lighting. Each vessel must be equipped with at least two...

  6. 46 CFR 129.450 - Portable lighting.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Portable lighting. 129.450 Section 129.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Lighting Systems § 129.450 Portable lighting. Each vessel must be equipped with at least two...

  7. 46 CFR 129.450 - Portable lighting.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Portable lighting. 129.450 Section 129.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Lighting Systems § 129.450 Portable lighting. Each vessel must be equipped with at least two...

  8. Portable direct methanol fuel cell systems

    NASA Technical Reports Server (NTRS)

    Narayanan, S. R.; Valdez, T. I.

    2002-01-01

    This article includes discussion of the specific power and power density requirements for various portable system applications, the status of stack technology, progress in the implementation of balance-of-plant designs, and a summary of the characteristics of various DMFC portable power source demonstrations.

  9. Do Portable Classrooms Impact Teaching and Learning?

    ERIC Educational Resources Information Center

    Chan, Tak Cheung

    2009-01-01

    Purpose: The purpose of this paper is to examine the possible impact portable classrooms have on the teaching and learning process by exploring current related literature. Design/methodology/approach: This paper takes a synthesis approach, analyzing current studies to assess the impact of portable classrooms on teaching and learning. Findings: No…

  10. Portable Micros: Potentials for Information Management.

    ERIC Educational Resources Information Center

    Davis, Charles H.

    1984-01-01

    Description of portable microcomputers discusses design features of Tandy TRS-80, Nippon Electric Company PC-8200, Epson HX-20, Texas Instruments TI CC 40, and Convergent Technologies' Workslate and provides several caveats and recommendations to those making purchasing decisions. Potential uses for portable microcomputers in education are also…

  11. 49 CFR 180.603 - Qualification of portable tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the Convention for Safe Containers (CSC). (e) Exemption portable tanks based on DOT 51 portable tanks... for one year thereafter, the owner of the portable tank must retain on file, at its principal place...

  12. Feasibility of an Electronic Survey on iPads with In-Person Data Collectors for Data Collection with Health Care Professionals and Health Care Consumers in General Emergency Departments

    PubMed Central

    Albrecht, Lauren; Given, Lisa M; Arseneau, Danielle; Klassen, Terry P

    2016-01-01

    Background Translating Emergency Knowledge for Kids was established to bridge the research-practice gap in pediatric emergency care by bringing the best evidence to Canadian general emergency departments (EDs). The first step in this process was to conduct a national needs assessment to determine the information needs and preferences of health professionals and parents in this clinical setting. Objective To describe the development and implementation of two electronic surveys, and determine the feasibility of collecting electronic survey data on iPads with in-person data collectors in a busy clinical environment. Methods Two descriptive surveys were conducted in 32 general EDs. Specific factors were addressed in four survey development and implementation stages: survey design, survey delivery, survey completion, and survey return. Feasibility of the data collection approach was determined by evaluating participation rates, completion rates, average survey time to completion, and usability of the platform. Usability was assessed with the in-person data collectors on five key variables: interactivity, portability, innovativeness, security, and proficiency. Results Health professional participation rates (1561/2575, 60.62%) and completion rates (1471/1561, 94.23%) were strong. Parental participation rates (974/1099, 88.63%) and completion rates (897/974, 92.09%) were excellent. Mean time to survey completion was 28.08 minutes for health professionals and 43.23 minutes for parents. Data collectors rated the platform “positively” to “very positively” on all five usability variables. Conclusions A number of design and implementation considerations were explored and integrated into this mixed-mode survey data collection approach. Feasibility was demonstrated by the robust survey participation and completion rates, reasonable survey completion times, and very positive usability evaluation results. PMID:27358205

  13. Precise time dissemination via portable atomic clocks

    NASA Technical Reports Server (NTRS)

    Putkovich, K.

    1982-01-01

    The most precise operational method of time dissemination over long distances presently available to the Precise Time and Time Interval (PTTI) community of users is by means of portable atomic clocks. The Global Positioning System (GPS), the latest system showing promise of replacing portable clocks for global PTTI dissemination, was evaluated. Although GPS has the technical capability of providing superior world-wide dissemination, the question of present cost and future accessibility may require a continued reliance on portable clocks for a number of years. For these reasons a study of portable clock operations as they are carried out today was made. The portable clock system that was utilized by the U.S. Naval Observatory (NAVOBSY) in the global synchronization of clocks over the past 17 years is described and the concepts on which it is based are explained. Some of its capabilities and limitations are also discussed.

  14. Satellite sound broadcasting system, portable reception

    NASA Technical Reports Server (NTRS)

    Golshan, Nasser; Vaisnys, Arvydas

    1990-01-01

    Studies are underway at JPL in the emerging area of Satellite Sound Broadcast Service (SSBS) for direct reception by low cost portable, semi portable, mobile and fixed radio receivers. This paper addresses the portable reception of digital broadcasting of monophonic audio with source material band limited to 5 KHz (source audio comparable to commercial AM broadcasting). The proposed system provides transmission robustness, uniformity of performance over the coverage area and excellent frequency reuse. Propagation problems associated with indoor portable reception are considered in detail and innovative antenna concepts are suggested to mitigate these problems. It is shown that, with the marriage of proper technologies a single medium power satellite can provide substantial direct satellite audio broadcast capability to CONUS in UHF or L Bands, for high quality portable indoor reception by low cost radio receivers.

  15. Use of electronic cigarettes (e-cigarettes) impairs indoor air quality and increases FeNO levels of e-cigarette consumers.

    PubMed

    Schober, Wolfgang; Szendrei, Katalin; Matzen, Wolfgang; Osiander-Fuchs, Helga; Heitmann, Dieter; Schettgen, Thomas; Jörres, Rudolf A; Fromme, Hermann

    2014-07-01

    Despite the recent popularity of e-cigarettes, to date only limited data is available on their safety for both users and secondhand smokers. The present study reports a comprehensive inner and outer exposure assessment of e-cigarette emissions in terms of particulate matter (PM), particle number concentrations (PNC), volatile organic compounds (VOC), polycyclic aromatic hydrocarbons (PAH), carbonyls, and metals. In six vaping sessions nine volunteers consumed e-cigarettes with and without nicotine in a thoroughly ventilated room for two hours. We analyzed the levels of e-cigarette pollutants in indoor air and monitored effects on FeNO release and urinary metabolite profile of the subjects. For comparison, the components of the e-cigarette solutions (liquids) were additionally analyzed. During the vaping sessions substantial amounts of 1,2-propanediol, glycerine and nicotine were found in the gas-phase, as well as high concentrations of PM2.5 (mean 197 μg/m(3)). The concentration of putative carcinogenic PAH in indoor air increased by 20% to 147 ng/m(3), and aluminum showed a 2.4-fold increase. PNC ranged from 48,620 to 88,386 particles/cm(3) (median), with peaks at diameters 24-36 nm. FeNO increased in 7 of 9 individuals. The nicotine content of the liquids varied and was 1.2-fold higher than claimed by the manufacturer. Our data confirm that e-cigarettes are not emission-free and their pollutants could be of health concern for users and secondhand smokers. In particular, ultrafine particles formed from supersaturated 1,2-propanediol vapor can be deposited in the lung, and aerosolized nicotine seems capable of increasing the release of the inflammatory signaling molecule NO upon inhalation. In view of consumer safety, e-cigarettes and nicotine liquids should be officially regulated and labeled with appropriate warnings of potential health effects, particularly of toxicity risk in children.

  16. Portable vapor diffusion coefficient meter

    DOEpatents

    Ho, Clifford K.

    2007-06-12

    An apparatus for measuring the effective vapor diffusion coefficient of a test vapor diffusing through a sample of porous media contained within a test chamber. A chemical sensor measures the time-varying concentration of vapor that has diffused a known distance through the porous media. A data processor contained within the apparatus compares the measured sensor data with analytical predictions of the response curve based on the transient diffusion equation using Fick's Law, iterating on the choice of an effective vapor diffusion coefficient until the difference between the predicted and measured curves is minimized. Optionally, a purge fluid can forced through the porous media, permitting the apparatus to also measure a gas-phase permeability. The apparatus can be made lightweight, self-powered, and portable for use in the field.

  17. Portable convertible blast effects shield

    SciTech Connect

    Pastrnak, John W.; Hollaway, Rocky; Henning, Carl D.; Deteresa, Steve; Grundler, Walter; Hagler,; Lisle B.; Kokko, Edwin; Switzer, Vernon A

    2010-10-26

    A rapidly deployable portable convertible blast effects shield/ballistic shield includes a set two or more telescoping cylindrical rings operably connected to each other to convert between a telescopically-collapsed configuration for storage and transport, and a telescopically-extended upright configuration forming an expanded inner volume. In a first embodiment, the upright configuration provides blast effects shielding, such as against blast pressures, shrapnel, and/or fire balls. And in a second embodiment, the upright configuration provides ballistic shielding, such as against incoming weapons fire, shrapnel, etc. Each ring has a high-strength material construction, such as a composite fiber and matrix material, capable of substantially inhibiting blast effects and impinging projectiles from passing through the shield. And the set of rings are releasably securable to each other in the telescopically-extended upright configuration, such as by click locks.

  18. Portable convertible blast effects shield

    DOEpatents

    Pastrnak, John W.; Hollaway, Rocky; Henning, Carl D.; Deteresa, Steve; Grundler, Walter; Hagler, Lisle B.; Kokko, Edwin; Switzer, Vernon A

    2007-05-22

    A rapidly deployable portable convertible blast effects shield/ballistic shield includes a set two or more telescoping cylindrical rings operably connected to each other to convert between a telescopically-collapsed configuration for storage and transport, and a telescopically-extended upright configuration forming an expanded inner volume. In a first embodiment, the upright configuration provides blast effects shielding, such as against blast pressures, shrapnel, and/or fire balls. And in a second embodiment, the upright configuration provides ballistic shielding, such as against incoming weapons fire, shrapnel, etc. Each ring has a high-strength material construction, such as a composite fiber and matrix material, capable of substantially inhibiting blast effects and impinging projectiles from passing through the shield. And the set of rings are releasably securable to each other in the telescopically-extended upright configuration, such as by click locks.

  19. Compact portable electric power sources

    SciTech Connect

    Fry, D.N.; Holcomb, D.E.; Munro, J.K.; Oakes, L.C.; Matson, M.J.

    1997-02-01

    This report provides an overview of recent advances in portable electric power source (PEPS) technology and an assessment of emerging PEPS technologies that may meet US Special Operations Command`s (SOCOM) needs in the next 1--2- and 3--5-year time frames. The assessment was performed through a literature search and interviews with experts in various laboratories and companies. Nineteen PEPS technologies were reviewed and characterized as (1) PEPSs that meet SOCOM requirements; (2) PEPSs that could fulfill requirements for special field conditions and locations; (3) potentially high-payoff sources that require additional R and D; and (4) sources unlikely to meet present SOCOM requirements. 6 figs., 10 tabs.

  20. RTOS kernel in portable electrocardiograph

    NASA Astrophysics Data System (ADS)

    Centeno, C. A.; Voos, J. A.; Riva, G. G.; Zerbini, C.; Gonzalez, E. A.

    2011-12-01

    This paper presents the use of a Real Time Operating System (RTOS) on a portable electrocardiograph based on a microcontroller platform. All medical device digital functions are performed by the microcontroller. The electrocardiograph CPU is based on the 18F4550 microcontroller, in which an uCOS-II RTOS can be embedded. The decision associated with the kernel use is based on its benefits, the license for educational use and its intrinsic time control and peripherals management. The feasibility of its use on the electrocardiograph is evaluated based on the minimum memory requirements due to the kernel structure. The kernel's own tools were used for time estimation and evaluation of resources used by each process. After this feasibility analysis, the migration from cyclic code to a structure based on separate processes or tasks able to synchronize events is used; resulting in an electrocardiograph running on one Central Processing Unit (CPU) based on RTOS.

  1. Portable convertible blast effects shield

    DOEpatents

    Pastrnak, John W.; Hollaway, Rocky; Henning, Carl D.; Deteresa, Steve; Grundler, Walter; Hagler, Lisle B.; Kokko, Edwin; Switzer, Vernon A.

    2011-03-15

    A rapidly deployable portable convertible blast effects shield/ballistic shield includes a set two or more frusto-conically-tapered telescoping rings operably connected to each other to convert between a telescopically-collapsed configuration for storage and transport, and a telescopically-extended upright configuration forming an expanded inner volume. In a first embodiment, the upright configuration provides blast effects shielding, such as against blast pressures, shrapnel, and/or fire balls. And in a second embodiment, the upright configuration provides ballistic shielding, such as against incoming weapons fire, shrapnel, etc. Each ring has a high-strength material construction, such as a composite fiber and matrix material, capable of substantially inhibiting blast effects and impinging projectiles from passing through the shield. And the set of rings are releasably securable to each other in the telescopically-extended upright configuration by the friction fit of adjacent pairs of frusto-conically-tapered rings to each other.

  2. Implementing a Portable Trusted Environment

    NASA Astrophysics Data System (ADS)

    Zic, John; Nepal, Surya

    The development of trusted systems, as envisaged by the Trusted Computing Group, assumed that the computing environments are uniform in terms of their operational environment, including hardware configuration, execution of a standard set of applications, operating system and facilities and procedures that allow the issue, revocation and maintenance of critical encryption keys and authorization certificates. These assumptions may be applicable to a single managed enterprise infrastructure. However, in situations where the users are mobile, or the computing environment is heterogeneous and the Internet provides the connectivity, the management of trust between enterprises becomes overwhelmingly difficult, if not impossible. As a result, deployment and uptake of trusted secure systems based on Trusted Platform Module have not been as successful as first envisaged. In this paper, we report on our experiences in designing and implementing a prototype personal trusted device called the Trust Extension Device, or TED, that provides users with a portable trustworthy environment for conducting transactions on any Internet connected computer.

  3. PORTABLE ACOUSTIC MONITORING PACKAGE (PAMP)

    SciTech Connect

    John l. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Deepak Mehra

    2003-07-01

    The 1st generation acoustic monitoring package was designed to detect and analyze weak acoustic signals inside natural gas transmission lines. Besides a microphone it housed a three-inch diameter aerodynamic acoustic signal amplifier to maximize sensitivity to leak induced {Delta}p type signals. The theory and test results of this aerodynamic signal amplifier was described in the master's degree thesis of our Research Assistant Deepak Mehra who is about to graduate. To house such a large three-inch diameter sensor required the use of a steel 300-psi rated 4 inch weld neck flange, which itself weighed already 29 pounds. The completed 1st generation Acoustic Monitoring Package weighed almost 100 pounds. This was too cumbersome to mount in the field, on an access port at a pipeline shut-off valve. Therefore a 2nd generation and truly Portable Acoustic Monitor was built. It incorporated a fully self-contained {Delta}p type signal sensor, rated for line pressures up to 1000 psi with a base weight of only 6 pounds. This is the Rosemont Inc. Model 3051CD-Range 0, software driven sensor, which is believed to have industries best total performance. Its most sensitive unit was purchased with a {Delta}p range from 0 to 3 inch water. This resulted in the herein described 2nd generation: Portable Acoustic Monitoring Package (PAMP) for pipelines up to 1000 psi. Its 32-pound total weight includes an 18-volt battery. Together with a 3 pound laptop with its 4-channel data acquisition card, completes the equipment needed for field acoustic monitoring of natural gas transmission pipelines.

  4. A Case Study Analyzing the Reading Levels of Print and Electronic Health Education Material for Health Consumers with Low Levels of Literacy

    ERIC Educational Resources Information Center

    Gerstle, Alan John

    2010-01-01

    The purpose of this case study was to determine if two samples of health education literature (one in print media; the other in electronic media), and published by the same health education organization, provided the requisite reading level for their intended audiences: immigrants and native speakers with a fourth-grade level of literacy. A…

  5. 46 CFR 119.458 - Portable fuel systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... and related fuel lines and accessories, are prohibited except where used for portable dewatering pumps or outboard motor installations. (b) The design, construction and stowage of portable tanks...

  6. Consumer Financial Protection Bureau

    MedlinePlus

    ... Research Conference CFPB Researchers Consumer Complaint Database Mortgage Database (HMDA) Consumer Credit Trends Credit Card Surveys & Agreements Financial Well-Being Survey Help advance financial well-being ...

  7. View of the Lunar Portable Magnetometer (LPM)

    NASA Image and Video Library

    1970-12-21

    S70-56721 (December 1970) --- A close-up view of the Lunar Portable Magnetometer (LPM), which will be used by the crew of the Apollo 14 lunar landing mission during the second extravehicular activity (EVA). The LPM's components, a tripod-mounted flux-gate magnetometer sensor head and an electronics data package, connected by a 50-feet flat cable, function together to measure variations in the lunar magnetic field at several points on the geological traverse. Data gathered will be used to determine the location, strength and dimensions of magnetic sources, as well as knowledge of the local and total selenological structure. The LPM will be carried on the Modular Equipment Transporter (MET), and deployed by the lunar module pilot, who will align the sensor head at least 35 feet from the data package. The LM pilot will then return to the MET and verbally relay the LPM readouts to Earth. Astronaut Edgar D. Mitchell is the lunar module pilot for the Apollo 14 lunar landing mission.

  8. Portable thermo-photovoltaic power source

    DOEpatents

    Zuppero, Anthony C.; Krawetz, Barton; Barklund, C. Rodger; Seifert, Gary D.

    1997-01-14

    A miniature thermo-photovoltaic (TPV) device for generation of electrical power for use in portable electronic devices. A TPV power source is constructed to provide a heat source chemical reactor capable of using various fuels, such as liquid hydrocarbons, including but not limited to propane, LPG, butane, alcohols, oils and diesel fuels to generate a source of photons. A reflector dish guides misdirected photon energy from the photon source toward a photovoltaic array. A thin transparent protector sheet is disposed between the photon source and the array to reflect back thermal energy that cannot be converted to electricity, and protect the array from thermal damage. A microlens disposed between the protector sheet and the array further focuses the tailored band of photon energy from the photon source onto an array of photovoltaic cells, whereby the photon energy is converted to electrical power. A heat recuperator removes thermal energy from reactor chamber exhaust gases, preferably using mini- or micro-bellows to force air and fuel past the exhaust gases, and uses the energy to preheat the fuel and oxidant before it reaches the reactor, increasing system efficiency. Mini- or micro-bellows force ambient air through the system both to supply oxidant and to provide cooling. Finally, an insulator, which is preferably a super insulator, is disposed around the TPV power source to reduce fuel consumption, and to keep the TPV power source cool to the touch so it can be used in hand-held devices.

  9. Portable fluorescence photometer for monitoring free calcium

    NASA Astrophysics Data System (ADS)

    Struckmeier, Jens; Klopp, Erk; Born, Matthias; Hofmann, Martin; Tenbosch, Jochen; Jones, David B.

    2000-12-01

    We introduce a compact and portable photometric system for measurements of the calcium dynamics in cells. The photometer is designed for applications in centrifuges or in zero gravity environment and thus extremely compact and reliable. It operates with the calcium-sensitive dye Indo-1. The excitation wavelength of 345 nm is generated by frequency doubling of a laser diode. Two compact photomultiplier tubes detect the fluorescent emission. The electronics provide the sensitivity of photon counting combined with simultaneous measurement of the temperature, of air pressure, and of gravitational force. Internal data storage during the experiment is possible. A newly developed cell chamber stabilizes the cell temperature to 37.0±0.1 °C and includes a perfusion system to supply the cells with medium. The system has a modular setup providing the possibility of changing the light source and detectors for investigation of ions other than calcium. Measurements of the intracellular calcium concentration are based on a comprehensive calibration of our system. First experiments show that the calcium dynamics of osteosarcoma cells stimulated by parathyroid hormone is observable.

  10. Portable Handheld Optical Window Inspection Device

    NASA Technical Reports Server (NTRS)

    Ihlefeld, Curtis; Dokos, Adam; Burns, Bradley

    2010-01-01

    The Portable Handheld Optical Window Inspection Device (PHOWID) is a measurement system for imaging small defects (scratches, pits, micrometeor impacts, and the like) in the field. Designed primarily for window inspection, PHOWID attaches to a smooth surface with suction cups, and raster scans a small area with an optical pen in order to provide a three-dimensional image of the defect. PHOWID consists of a graphical user interface, motor control subsystem, scanning head, and interface electronics, as well as an integrated camera and user display that allows a user to locate minute defects before scanning. Noise levels are on the order of 60 in. (1.5 m). PHOWID allows field measurement of defects that are usually done in the lab. It is small, light, and attaches directly to the test article in any orientation up to vertical. An operator can scan a defect and get useful engineering data in a matter of minutes. There is no need to make a mold impression for later lab analysis.

  11. Whip antenna design for portable rf systems

    NASA Astrophysics Data System (ADS)

    Ponnapalli, Saila; Canora, Frank J.

    1995-12-01

    Whip type antennas are probably the most commonly used antennas in portable rf systems, such as cordless and cellular phones, rf enabled laptop computers, personal digital assistants (PDAs), and handheld computers. Whip antennas are almost always mounted on the chassis which contains the radio and other electronics. The chassis is usually a molded plastic which is coated with a conducting paint for EMI purposes. The chassis which appears as a lossy conductor to the antenna, has several effects -- detuning, altering the gain of the antenna, and shadowing its radiation pattern. Extensive modeling and measurements must be performed in order to fully characterize the affects of the chassis on the whip antenna, and to optimize antenna type, orientation and position. In many instances, modeling plays a more important role in prediction of the performance of whip antennas, since measurements become difficult due to the presence of common mode current on feed cables. In this paper models and measurements are used to discuss the optimum choice of whip antennas and the impact of the chassis on radiation characteristics. A modeling tool which has been previously described and has been successfully used to predict radiated field patterns is used for simulations, and measured and modeled results are shown.

  12. A portable powered ankle-foot orthosis for rehabilitation.

    PubMed

    Shorter, K Alex; Kogler, Géza F; Loth, Eric; Durfee, William K; Hsiao-Wecksler, Elizabeth T

    2011-01-01

    Innovative technological advancements in the field of orthotics, such as portable powered orthotic systems, could create new treatment modalities to improve the functional out come of rehabilitation. In this article, we present a novel portable powered ankle-foot orthosis (PPAFO) to provide untethered assistance during gait. The PPAFO provides both plantar flexor and dorsiflexor torque assistance by way of a bidirectional pneumatic rotary actuator. The system uses a portable pneumatic power source (compressed carbon dioxide bottle) and embedded electronics to control the actuation of the foot. We collected pilot experimental data from one impaired and three nondisabled subjects to demonstrate design functionality. The impaired subject had bilateral impairment of the lower legs due to cauda equina syndrome. We found that data from nondisabled walkers demonstrated the PPAFO's capability to provide correctly timed plantar flexor and dorsiflexor assistance during gait. Reduced activation of the tibialis anterior during stance and swing was also seen during assisted nondisabled walking trials. An increase in the vertical ground reaction force during the second half of stance was present during assisted trials for the impaired subject. Data from nondisabled walkers demonstrated functionality, and data from an impaired walker demonstrated the ability to provide functional plantar flexor assistance.

  13. Evaluating Performance Portability of OpenACC

    SciTech Connect

    Sabne, Amit J; Sakdhnagool, Putt; Lee, Seyong; Vetter, Jeffrey S

    2015-01-01

    Accelerator-based heterogeneous computing is gaining momentum in High Performance Computing arena. However, the increased complexity of the accelerator architectures demands more generic, high-level programming models. OpenACC is one such attempt to tackle the problem. While the abstraction endowed by OpenACC offers productivity, it raises questions on its portability. This paper evaluates the performance portability obtained by OpenACC on twelve OpenACC programs on NVIDIA CUDA, AMD GCN, and Intel MIC architectures. We study the effects of various compiler optimizations and OpenACC program settings on these architectures to provide insights into the achieved performance portability.

  14. Architecture for portable direct liquid fuel cells

    NASA Astrophysics Data System (ADS)

    Qian, Weimin; Wilkinson, David P.; Shen, Jun; Wang, Haijiang; Zhang, Jiujun

    Direct fuel cells (DFCs) are receiving increased interest for portable power applications. Cell and stack architecture is a vital technical issue for portable DFCs. The architecture of a DFC not only has to meet particular application requirements such as a compact size and easy handling, but also has to ensure desired performance, reliability and fabrication costs. In this paper, the most recent advances related to portable DFCs and their architecture are reviewed. The current status of system architecture, stack/unit cell architecture, flow-field designs and MEA morphology strategies along with analysis are surveyed. In addition, promising methods of passive fuel delivery are also presented.

  15. A Portable, High Resolution, Surface Measurement Device

    NASA Technical Reports Server (NTRS)

    Ihlefeld, Curtis M.; Burns, Bradley M.; Youngquist, Robert C.

    2012-01-01

    A high resolution, portable, surface measurement device has been demonstrated to provide micron-resolution topographical plots. This device was specifically developed to allow in-situ measurements of defects on the Space Shuttle Orbiter windows, but is versatile enough to be used on a wide variety of surfaces. This paper discusses the choice of an optical sensor and then the decisions required to convert a lab bench optical measurement device into an ergonomic portable system. The necessary trade-offs between performance and portability are presented along with a description of the device developed to measure Orbiter window defects.

  16. Characterizing solar mirror materials using portable reflectometers

    SciTech Connect

    Pettit, R.B.

    1982-09-01

    Currently available portable instrumentation for hemispherical and specular reflectance measurements of solar mirror materials is discussed. Particular attention is given to the wavelength dependence of the measurement spectrum, which in most cases does not approximate a solar spectral distribution, and to other limitations of each instrument. Because a portable instrument is not available that can determine the solar averaged specular reflectance from a single measurement, two procedures are recommended for obtaining a reasonable estimate for this quantity using the existing portable equipment. Finally, future developments in this area are briefly discussed.

  17. Combining Portable Raman Probes with Nanotubes for Theranostic Applications

    PubMed Central

    Bhirde, Ashwinkumar A.; Liu, Gang; Jin, Albert; Iglesias-Bartolome, Ramiro; Sousa, Alioscka A.; Leapman, Richard D.; Gutkind, J. Silvio; Lee, Seulki; Chen, Xiaoyuan

    2011-01-01

    Recently portable Raman probes have emerged along with a variety of applications, including carbon nanotube (CNT) characterization. Aqueous dispersed CNTs have shown promise for biomedical applications such as drug/gene delivery vectors, photo-thermal therapy, and photoacoustic imaging. In this study we report the simultaneous detection and irradiation of carbon nanotubes in 2D monolayers of cancer cells and in 3D spheroids using a portable Raman probe. A portable handheld Raman instrument was utilized for dual purposes: as a CNT detector and as an irradiating laser source. Single-walled carbon nanotubes (SWCNTs) and multi-walled carbon nanotubes (MWCNTs) were dispersed aqueously using a lipid-polymer (LP) coating, which formed highly stable dispersions both in buffer and cell media. The LP coated SWCNT and MWCNT aqueous dispersions were characterized by atomic force microscopy, transmission electron microscopy, dynamic light scattering, Fourier transform infrared spectroscopy and Raman spectroscopy. The cellular uptake of the LP-dispersed SWCNTs and MWCNTs was observed using confocal microscopy, and fluorescein isothiocyanate (FITC)-nanotube conjugates were found to be internalized by ovarian cancer cells by using Z-stack fluorescence confocal imaging. Biocompatibility of SWCNTs and MWCNTs was assessed using a cell viability MTT assay, which showed that the nanotube dispersions did not hinder the proliferation of ovarian cancer cells at the dosage tested. Ovarian cancer cells treated with SWCNTs and MWCNTs were simultaneously detected and irradiated live in 2D layers of cancer cells and in 3D environments using the portable Raman probe. An apoptotic terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) assay carried out after laser irradiation confirmed that cell death occurred only in the presence of nanotube dispersions. We show for the first time that both SWCNTs and MWCNTs can be selectively irradiated and detected in cancer cells using a simple

  18. Anticipatory Consumer Socialization.

    ERIC Educational Resources Information Center

    Moore, Roy L.; Moschis, George P.

    Anticipatory consumer socialization is the learning of consumer roles and perceptions, which will be assumed at a later time, such as those that children acquire before they become adult consumers. A survey of 784 adolescents was conducted in a southern state to examine the anticipatory consumer socialization effects of such factors as the mass…

  19. Portable Unit for Metabolic Analysis

    NASA Technical Reports Server (NTRS)

    Dietrich, Daniel L.; Pitch, Nancy D.; Lewis, Mark E.; Juergens, Jeffrey R.; Lichter, Michael J.; Stuk, Peter M.; Diedrick, Dale M.; Valentine, Russell W.; Pettegrew, Richard D.

    2007-01-01

    The Portable Unit for Metabolic Analysis (PUMA) is an instrument that measures several quantities indicative of human metabolic function. Specifically, this instrument makes time-resolved measurements of temperature, pressure, flow, and the partial pressures of oxygen and carbon dioxide in breath during both inhalation and exhalation. Portable instruments for measuring these quantities have been commercially available, but the response times of those instruments are too long to enable temporal resolution of phenomena on the time scales of human respiration cycles. In contrast, the response time of the PUMA is significantly shorter than characteristic times of human respiration phenomena, making it possible to analyze varying metabolic parameters, not only on sequential breath cycles but also at successive phases of inhalation and exhalation within the same breath cycle. In operation, the PUMA is positioned to sample breath near the subject s mouth. Commercial off-the-shelf sensors are used for three of the measurements: a miniature pressure transducer for pressure, a thermistor for temperature, and an ultrasonic sensor for flow. Sensors developed at Glenn Research Center are used for measuring the partial pressures of oxygen and carbon dioxide: The carbon dioxide sensor exploits the relatively strong absorption of infrared light by carbon dioxide. Light from an infrared source passes through the stream of inhaled or exhaled gas and is focused on an infrared- sensitive photodetector. The oxygen sensor exploits the effect of oxygen in quenching the fluorescence of ruthenium-doped organic molecules in a dye on the tip of an optical fiber. A blue laser diode is used to excite the fluorescence, and the optical fiber carries the fluorescent light to a photodiode, the temporal variation of the output of which bears a known relationship with the rate of quenching of fluorescence and, hence, with the partial pressure of oxygen. The outputs of the sensors are digitized

  20. Portable digital Satellite News Gathering (SNG) RF terminal using a flat antenna

    NASA Astrophysics Data System (ADS)

    Murata, Takao; Mitsumoto, Hideo; Fujita, Masaru; Tanaka, Shoji; Takano, Kouichi; Imai, Kazuo; Toyama, Noboru

    1995-05-01

    In this paper, a Ku-band portable SNG RF terminal using a flat antenna is proposed for making the best use of digital SNG systems. This portable terminal uses 16 planar microstrip subarray antennas, each with a solid-state power amplifier (SSPA) mounted on its rear. The proposed RF terminal is different from a conventional portable RF terminal with parabolic antenna in that it has electronic tracking capability. Electronic antenna tracking reduces time it takes to set up the terminal because precise alignment of the antenna is not required. The flat antenna meets the design objectives specified by the ITU-R Recommendations. The SSPA's have an efficiency of 21 percent and a power output of 5 W. The tracking performance of the feedback system which uses four subarrays, is also presented.

  1. Portable Dextrous Force Feedback Master for robot telemanipulation (PDMFF)

    NASA Technical Reports Server (NTRS)

    Burdea, Grigore C.; Speeter, Thomas H.

    1989-01-01

    A major drawback of open loop masters is a lack of force feedback, limiting their ability to perform complex tasks such as assembly and repair. Researchers present a simple dextrous force feedback master for computer assisted telemanipulation. The device is compact, portable and can be held in the operator hand, without the need for a special joystick or console. The system is capable of both position feed forward and force feedback, using electronic position sensors and a pneumatic micro-actuator. The level of forces exercised by the pneumatic actuator is such that near rigidity may be attained. Experimental results showing good system linearity and small time lag are given.

  2. Lifetime-based portable instrument for blood gas analysis

    NASA Astrophysics Data System (ADS)

    Kieslinger, Dietmar; Trznadel, Karolina; Oechs, Karin; Draxler, Sonja; Lippitsch, Max E.

    1997-06-01

    A portable, compact device for measuring blood gases by using the fluorescence decay time as the information carrier is presented. The instrument is based on solid state technology only, thus using LEDs for excitation and a photodiode as detector. A capillary coated on its inner surface with different sensing membranes serves as a sample compartment and an optical sensor element simultaneously. Furthermore, due to inhomogeneous waveguiding in the capillary walls, only the fluorescent light is guided. Technical details of the electronic circuit, the optical design and the instrumental performance will be discussed.

  3. Photonic Crystal Enabled Thermophotovoltaics for a Portable Microgenerator

    NASA Astrophysics Data System (ADS)

    Chan, Walker R.; Stelmakh, Veronika; Waits, Christopher M.; Soljacic, Marin; Joannopoulos, John D.; Celanovic, Ivan

    2015-12-01

    This work presents the design and characterization of a first-of-a-kind millimeter- scale thermophotovoltaic (TPV) system using a metallic microburner, photonic crystal emitter, and low-bandgap photovoltaic (PV) cells. In our TPV system, combustion heats the emitter to incandescence and the resulting thermal radiation is converted to electricity by the low bandgap PV cells. Our motivation is to harness the high specific energy of hydrocarbon fuels at the micro- and millimeter-scale in order to meet the increasing power demands of micro robotics and portable electronics. Our experimental demonstration lays the groundwork for developing a TPV microgenerator as a viable battery replacement.

  4. Portable basketball rim testing device

    DOEpatents

    Abbott, W. Bruce; Davis, Karl C.

    1993-01-01

    A portable basketball rim rebound testing device 10 is illustrated in two preferred embodiments for testing the rebound or energy absorption characteristics of a basketball rim 12 and its accompanying support to determine likely rebound or energy absorption charcteristics of the system. The apparatus 10 includes a depending frame 28 having a C-clamp 36 for releasably rigidly connecting the frame to the basketball rim 12. A glide weight 60 is mounted on a guide rod 52 permitting the weight 60 to be dropped against a calibrated spring 56 held on an abutment surface on the rod to generate for deflecting the basketball rim and then rebounding the weight upwardly. A photosensor 66 is mounted on the depending frame 28 to sense passage of reflective surfaces 75 on the weight to thereby obtain sufficient data to enable a processing means 26 to calculate the rebound velocity and relate it to an energy absorption percentage rate of the rim system 12. A readout is provided to display the energy absorption percentage.

  5. Development of portable fuel cells

    SciTech Connect

    Nakatou, K.; Sumi, S.; Nishizawa, N.

    1996-12-31

    Sanyo Electric has been concentrating on developing a marketable portable fuel cell using phosphoric acid fuel cells (PAFC). Due to the fact that this power source uses PAFC that operate at low temperature around 100{degrees} C, they are easier to handle compared to conventional fuel cells that operate at around 200{degrees} C , they can also be expected to provide extended reliable operation because corrosion of the electrode material and deterioration of the electrode catalyst are almost completely nonexistent. This power source is meant to be used independently and stored at room temperature. When it is started up, it generates electricity itself using its internal load to raise the temperature. As a result, the phosphoric acid (the electolyte) absorbs the reaction water when the temperature starts to be raised (around room temperature). At the same time the concentration and volume of the phosphoric acid changes, which may adversely affect the life time of the cell. We have studied means for starting, operating PAFC stack using methods that can simply evaluate changes in the concentration of the electrolyte in the stack with the aim of improving and extending cell life and report on them in this paper.

  6. Portable Microleak-Detection System

    NASA Technical Reports Server (NTRS)

    Rivers, H. Kevin; Sikora, Joseph G.; Sankaran, Sankara N.

    2007-01-01

    The figure schematically depicts a portable microleak-detection system that has been built especially for use in testing hydrogen tanks made of polymer-matrix composite materials. (As used here, microleak signifies a leak that is too small to be detectable by the simple soap-bubble technique.) The system can also be used to test for microleaks in tanks that are made of other materials and that contain gases other than hydrogen. Results of calibration tests have shown that measurement errors are less than 10 percent for leak rates ranging from 0.3 to 200 cm3/min. Like some other microleak-detection systems, this system includes a vacuum pump and associated plumbing for sampling the leaking gas, and a mass spectrometer for analyzing the molecular constituents of the gas. The system includes a flexible vacuum chamber that can be attached to the outer surface of a tank or other object of interest that is to be tested for leakage (hereafter denoted, simply, the test object). The gas used in a test can be the gas or vapor (e.g., hydrogen in the original application) to be contained by the test object. Alternatively, following common practice in leak testing, helium can be used as a test gas. In either case, the mass spectrometer can be used to verify that the gas measured by the system is the test gas rather than a different gas and, hence, that the leak is indeed from the test object.

  7. Manual resuscitators and portable ventilators.

    PubMed

    Phillips, G D; Skowronski, G A

    1986-08-01

    This paper reviews the state of the art in Australia of manually operated, self-inflating bag resuscitators, including the Laerdal, Air Viva and Ambu; manually operated bags dependent upon an oxygen supply, including Mapleson B, C, E and F, the CIG Medishield Oxy-Saver and modified Oxy-Viva Resuscitator 3, and the Komesaroff Oxy-Resuscitator RD85; oxygen-powered resuscitators, including the Oxy-Viva Resuscitator 3 with Demand and RM2 Valves, and the Oxylife FM85; and portable ventilators, including the Drager Oxylog, and Ohmeda Logic 07. Specific comment is made to the effect that the design of the resuscitator is often less important than the knowledge and ability of the operator in using the equipment to achieve adequate lung ventilation. The simplest, cheapest, most useful resuscitators are the manually operated self-inflating bag assemblies. With special training, use of more complex equipment can be justified in some circumstances. The more complex the equipment, the greater the risk of inappropriate use, and the greater the risk of equipment malfunction unless a regular maintenance program is followed.

  8. Scalable, extensible, and portable numerical libraries

    SciTech Connect

    Gropp, W.; Smith, B.

    1995-01-01

    Designing a scalable and portable numerical library requires consideration of many factors, including choice of parallel communication technology, data structures, and user interfaces. The PETSc library (Portable Extensible Tools for Scientific computing) makes use of modern software technology to provide a flexible and portable implementation. This talk will discuss the use of a meta-communication layer (allowing the user to choose different transport layers such as MPI, p4, pvm, or vendor-specific libraries) for portability, an aggressive data-structure-neutral implementation that minimizes dependence on particular data structures (even vectors), permitting the library to adapt to the user rather than the other way around, and the separation of implementation language from user-interface language. Examples are presented.

  9. 77 FR 31894 - Portable Gauge Licenses

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-30

    ... materials, protection of sensitive information, a revised appendix on training for portable gauge users, and changes in regulatory policies and practices. This document is intended for use by applicants,...

  10. The Portable War Room Research Project

    NASA Technical Reports Server (NTRS)

    Govers, Francis X., III; Fry, Mark

    1997-01-01

    The Portable War Room is an internal TASC project to research and develop a visualization and simulation environment to provide for decision makers the power to review the past, understand the present, and peer into the future.

  11. Portable breathing apparatus for coal mines

    NASA Technical Reports Server (NTRS)

    Vandolah, R. W.

    1972-01-01

    The state of the art in portable oxygen breathing equipment is reported. Considered are self-containing as well as chemically generating oxygen sources and their effectiveness and limitations in mine rescue operations.

  12. Portable, Folding Tray Retainer and Stand (Multipurpose).

    DTIC Science & Technology

    The invention relates generally to the field of service tray supports and, in particular, to an improved combined portable tray support and stand especially adaptable for use with a litter-borne patient.

  13. Evaluation of a portable air purifier.

    PubMed

    Lawrence, J C; Lilly, H A; Wilkins, M D

    1981-04-01

    A portable air purifier significantly reduced mal odour in a small room. If the atmosphere was deliberately contaminated with Serratia marcescens the unit rapidly removed this organism. However, if incorrectly sited, the purifier could disperse organisms into the atmosphere.

  14. The Portable War Room Research Project

    NASA Technical Reports Server (NTRS)

    Govers, Francis X., III; Fry, Mark

    1997-01-01

    The Portable War Room is an internal TASC project to research and develop a visualization and simulation environment to provide for decision makers the power to review the past, understand the present, and peer into the future.

  15. Linking PBDEs in house dust to consumer products using X-ray fluorescence.

    PubMed

    Allen, Joseph G; McClean, Michael D; Stapleton, Heather M; Webster, Thomas F

    2008-06-01

    The indoor environment is an important source of exposure to polybrominated diphenyl ethers (PBDEs), a class of fire retardants used in many household products. Previous attempts to link PBDE concentrations in house dust to consumer products have been hampered by the inability to determine the presence of PBDEs in otherwise similar products. We used a portable X-rayfluorescence (XRF) analyzer to nondestructively quantify bromine concentrations in consumer goods. In the validation phase, XRF-measured bromine was highly correlated with GC/MS-measured bromine for furniture foam and plastic from electronics (n = 29, r = 0.93, p < 0.0001). In the field study phase, the XRF-measured bromine in room furniture was associated with pentaBDE concentrations in room dust in the bedroom (r = 0.68, p = 0.001) and main living area (r = 0.51, p = 0.02). We also found an association between XRF-measured bromine levels in electronics and decaBDE levels in dust, largely driven by the high levels in televisions (r = 0.64, p = 0.003 for bedrooms). For the main living area, predicting decaBDE in dust improved when we included an interaction effect between the bromine content of televisions and the number of persons in the house (p < 0.005), a potential surrogate for television usage.

  16. 46 CFR 182.458 - Portable fuel systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Portable fuel systems. 182.458 Section 182.458 Shipping...) MACHINERY INSTALLATION Specific Machinery Requirements § 182.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where...

  17. 46 CFR 182.458 - Portable fuel systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Portable fuel systems. 182.458 Section 182.458 Shipping...) MACHINERY INSTALLATION Specific Machinery Requirements § 182.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where...

  18. 46 CFR 182.458 - Portable fuel systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Portable fuel systems. 182.458 Section 182.458 Shipping...) MACHINERY INSTALLATION Specific Machinery Requirements § 182.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where...

  19. 46 CFR 182.458 - Portable fuel systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) MACHINERY INSTALLATION Specific Machinery Requirements § 182.458 Portable fuel systems. (a) Portable fuel... for portable dewatering pumps or outboard motor installations. (b) The design, construction, and stowage of portable tanks and related fuel lines and accessories must meet the requirements of ABYC...

  20. 46 CFR 182.458 - Portable fuel systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Portable fuel systems. 182.458 Section 182.458 Shipping...) MACHINERY INSTALLATION Specific Machinery Requirements § 182.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where...