Time Pattern Locking Scheme for Secure Multimedia Contents in Human-Centric Device
Kim, Hyun-Woo; Kim, Jun-Ho; Park, Jong Hyuk; Jeong, Young-Sik
2014-01-01
Among the various smart multimedia devices, multimedia smartphones have become the most widespread due to their convenient portability and real-time information sharing, as well as various other built-in features. Accordingly, since personal and business activities can be carried out using multimedia smartphones without restrictions based on time and location, people have more leisure time and convenience than ever. However, problems such as loss, theft, and information leakage because of convenient portability have also increased proportionally. As a result, most multimedia smartphones are equipped with various built-in locking features. Pattern lock, personal identification numbers, and passwords are the most used locking features on current smartphones, but these are vulnerable to shoulder surfing and smudge attacks, allowing malicious users to bypass the security feature easily. In particular, the smudge attack technique is a convenient way to unlock multimedia smartphones after they have been stolen. In this paper, we propose the secure locking screen using time pattern (SLSTP) focusing on improved security and convenience for users to support human-centric multimedia device completely. The SLSTP can provide a simple interface to users and reduce the risk factors pertaining to security leakage to malicious third parties. PMID:25202737
Time pattern locking scheme for secure multimedia contents in human-centric device.
Kim, Hyun-Woo; Kim, Jun-Ho; Park, Jong Hyuk; Jeong, Young-Sik
2014-01-01
Among the various smart multimedia devices, multimedia smartphones have become the most widespread due to their convenient portability and real-time information sharing, as well as various other built-in features. Accordingly, since personal and business activities can be carried out using multimedia smartphones without restrictions based on time and location, people have more leisure time and convenience than ever. However, problems such as loss, theft, and information leakage because of convenient portability have also increased proportionally. As a result, most multimedia smartphones are equipped with various built-in locking features. Pattern lock, personal identification numbers, and passwords are the most used locking features on current smartphones, but these are vulnerable to shoulder surfing and smudge attacks, allowing malicious users to bypass the security feature easily. In particular, the smudge attack technique is a convenient way to unlock multimedia smartphones after they have been stolen. In this paper, we propose the secure locking screen using time pattern (SLSTP) focusing on improved security and convenience for users to support human-centric multimedia device completely. The SLSTP can provide a simple interface to users and reduce the risk factors pertaining to security leakage to malicious third parties.
ERIC Educational Resources Information Center
Lorah, Elizabeth R.; Parnell, Ashley; Whitby, Peggy Schaefer; Hantula, Donald
2015-01-01
Powerful, portable, off-the-shelf handheld devices, such as tablet based computers (i.e., iPad®; Galaxy®) or portable multimedia players (i.e., iPod®), can be adapted to function as speech generating devices for individuals with autism spectrum disorders or related developmental disabilities. This paper reviews the research in this new and rapidly…
Wireless augmented reality communication system
NASA Technical Reports Server (NTRS)
Devereaux, Ann (Inventor); Agan, Martin (Inventor); Jedrey, Thomas (Inventor)
2006-01-01
The system of the present invention is a highly integrated radio communication system with a multimedia co-processor which allows true two-way multimedia (video, audio, data) access as well as real-time biomedical monitoring in a pager-sized portable access unit. The system is integrated in a network structure including one or more general purpose nodes for providing a wireless-to-wired interface. The network architecture allows video, audio and data (including biomedical data) streams to be connected directly to external users and devices. The portable access units may also be mated to various non-personal devices such as cameras or environmental sensors for providing a method for setting up wireless sensor nets from which reported data may be accessed through the portable access unit. The reported data may alternatively be automatically logged at a remote computer for access and viewing through a portable access unit, including the user's own.
Wireless Augmented Reality Communication System
NASA Technical Reports Server (NTRS)
Jedrey, Thomas (Inventor); Agan, Martin (Inventor); Devereaux, Ann (Inventor)
2014-01-01
The system of the present invention is a highly integrated radio communication system with a multimedia co-processor which allows true two-way multimedia (video, audio, data) access as well as real-time biomedical monitoring in a pager-sized portable access unit. The system is integrated in a network structure including one or more general purpose nodes for providing a wireless-to-wired interface. The network architecture allows video, audio and data (including biomedical data) streams to be connected directly to external users and devices. The portable access units may also be mated to various non-personal devices such as cameras or environmental sensors for providing a method for setting up wireless sensor nets from which reported data may be accessed through the portable access unit. The reported data may alternatively be automatically logged at a remote computer for access and viewing through a portable access unit, including the user's own.
Wireless Augmented Reality Communication System
NASA Technical Reports Server (NTRS)
Agan, Martin (Inventor); Devereaux, Ann (Inventor); Jedrey, Thomas (Inventor)
2016-01-01
The system of the present invention is a highly integrated radio communication system with a multimedia co-processor which allows true two-way multimedia (video, audio, data) access as well as real-time biomedical monitoring in a pager-sized portable access unit. The system is integrated in a network structure including one or more general purpose nodes for providing a wireless-to-wired interface. The network architecture allows video, audio and data (including biomedical data) streams to be connected directly to external users and devices. The portable access units may also be mated to various non-personal devices such as cameras or environmental sensors for providing a method for setting up wireless sensor nets from which reported data may be accessed through the portable access unit. The reported data may alternatively be automatically logged at a remote computer for access and viewing through a portable access unit, including the user's own.
NASA Technical Reports Server (NTRS)
Scott, D. W.
1994-01-01
This report describes efforts to use digital motion video compression technology to develop a highly portable device that would convert 1990-91 era IBM-compatible and/or MacIntosh notebook computers into full-color, motion-video capable multimedia training systems. An architecture was conceived that would permit direct conversion of existing laser-disk-based multimedia courses with little or no reauthoring. The project did not physically demonstrate certain critical video keying techniques, but their implementation should be feasible. This investigation of digital motion video has spawned two significant spaceflight projects at MSFC: one to downlink multiple high-quality video signals from Spacelab, and the other to uplink videoconference-quality video in realtime and high quality video off-line, plus investigate interactive, multimedia-based techniques for enhancing onboard science operations. Other airborne or spaceborne spinoffs are possible.
A Research Program in Computer Technology. Volume 1
1981-08-01
rigidity, sensor networks 10. command and control, digital voice communication, graphic input device for terminal, multimedia communications, portable...satellite channel in the internetwork environment; Distributed Sensor Networks - formulation of algorithms and communication protocols to support the...operation of geographically distributed sensors ; Personal Communicator - work intended to result in a demonstration-level portable terminal to test and
Lorah, Elizabeth R; Parnell, Ashley; Whitby, Peggy Schaefer; Hantula, Donald
2015-12-01
Powerful, portable, off-the-shelf handheld devices, such as tablet based computers (i.e., iPad(®); Galaxy(®)) or portable multimedia players (i.e., iPod(®)), can be adapted to function as speech generating devices for individuals with autism spectrum disorders or related developmental disabilities. This paper reviews the research in this new and rapidly growing area and delineates an agenda for future investigations. In general, participants using these devices acquired verbal repertoires quickly. Studies comparing these devices to picture exchange or manual sign language found that acquisition was often quicker when using a tablet computer and that the vast majority of participants preferred using the device to picture exchange or manual sign language. Future research in interface design, user experience, and extended verbal repertoires is recommended.
Teaching students with developmental disabilities to operate an iPod Touch(®) to listen to music.
Kagohara, Debora M; Sigafoos, Jeff; Achmadi, Donna; van der Meer, Larah; O'Reilly, Mark F; Lancioni, Giulio E
2011-01-01
We evaluated an intervention procedure for teaching three students with developmental disabilities to independently operate a portable multimedia device (i.e., an iPod Touch(®)) to listen to music. The intervention procedure included the use of video modeling, which was presented on the same iPod Touch(®) that the students were taught to operate to listen to music. Four phases (i.e., baseline, intervention, fading, and follow-up) were arranged in accordance with a delayed multiple-probe across participants design. During baseline, the students performed from 25 to 62.5% of the task analyzed steps correctly. With intervention, all three students correctly performed 80-100% of the steps and maintained this level of performance when video modeling was removed and during follow-up. The findings suggest that the video modeling procedure was effective for teaching the students to independently operate a portable multimedia device to access age-appropriate leisure content. Copyright © 2011 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Kumar, Vikas; Sharma, Deepika
2016-01-01
Students in the digital era are habitual of using digital devices not only for playing and interacting with their friends and peers, but also as a tool for education and learning. These digital natives are highly obsessed with the internet driven portable devices and always demand for a multimedia rich content. This specific demand needs to be…
ERIC Educational Resources Information Center
Walinski, Jacek Tadeusz
2014-01-01
Portable multimedia devices shape the intensity of intercultural contacts not only through content consumption but also through content creation. Enabling learners to participate in content exchange via the Web 2.0 paradigm (audiences as both media consumers and media creators) can be employed to create new forms of acquiring knowledge. This study…
Multimedia Presentations on the Go: An Instruction and Buyer's Guide.
ERIC Educational Resources Information Center
Sammons, Martha C.
This handbook is designed to provide guidance for someone who wants to create portable multimedia presentations with notebook computers and related technologies. The first section offers technological overviews to help assess needs for: (1) portable computers; (2) software; (3) projection equipment; (4) peripherals; (5) portable storage; (6)…
[A Multimedia Tutorial to Train Ultrasonography of the Thyroid for Medical Students].
Ritter, Julia; Wolfram, Maximilian; Schuler, Stefan; Guntinas-Lichius, Orlando
2017-11-01
Physicians in education often have poor experience in practice and assessment of ultrasonography on entering their profession, due to a deficiency of training offers during their study of medicine. Hence, a multimedia device for stepwise learning and training ultrasonography of the thyroid was developed. A software for a portable ultrasonography system was used to design a multimedia device for ultrasonography of the thyroid. It allows the user to illustrate texts and pictorial material simultaneously with ultrasound examination in order to compare own findings with examples from a database. The device was evaluated by 8 medical students and compared to a tutor-guided training. A structured, stepwise manual for ultrasonography of the thyroid with a large content of examples in different sectional images was designed for simultaneous reconstruction with the ultrasonography device. The informative content of the device and the replicability of the examination procedure were evaluated positively. Assessment respecting clarity, eligibility for users without experience and learning success was varying. The tutorial to learn and train ultrasonography of the thyroid is an instrument for self-learning and improving practical education in ultrasonography in medical education. In the next version, the manual for the examination will be structured in greater detail. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Technical Reports Server (NTRS)
Losquadro, G.; Luglio, M.; Vatalaro, F.
1997-01-01
A geostationary satellite system for mobile multimedia services via portable, aeronautical and mobile terminals was developed within the framework of the Advanced Communications Technology Service (ACTS) programs. The architecture of the system developed under the 'satellite extremely high frequency communications for multimedia mobile services (SECOMS)/ACTS broadband aeronautical terminal experiment' (ABATE) project is presented. The system will be composed of a Ka band system component, and an extremely high frequency band component. The major characteristics of the space segment, the ground control station and the portable, aeronautical and mobile user terminals are outlined.
ERIC Educational Resources Information Center
Liu, Min; Navarrete, Cesar; Maradiegue, Erin; Wivagg, Jennifer
2014-01-01
Educators have become increasingly interested in the learning benefits that mobile technology can provide to students in and out of classrooms. While there is considerable enthusiasm for using mobile devices to support learning with their multimedia capabilities, portability, connectivity, and flexibility, there is a paucity of research evidence…
Multimedia architectures: from desktop systems to portable appliances
NASA Astrophysics Data System (ADS)
Bhaskaran, Vasudev; Konstantinides, Konstantinos; Natarajan, Balas R.
1997-01-01
Future desktop and portable computing systems will have as their core an integrated multimedia system. Such a system will seamlessly combine digital video, digital audio, computer animation, text, and graphics. Furthermore, such a system will allow for mixed-media creation, dissemination, and interactive access in real time. Multimedia architectures that need to support these functions have traditionally required special display and processing units for the different media types. This approach tends to be expensive and is inefficient in its use of silicon. Furthermore, such media-specific processing units are unable to cope with the fluid nature of the multimedia market wherein the needs and standards are changing and system manufacturers may demand a single component media engine across a range of products. This constraint has led to a shift towards providing a single-component multimedia specific computing engine that can be integrated easily within desktop systems, tethered consumer appliances, or portable appliances. In this paper, we review some of the recent architectural efforts in developing integrated media systems. We primarily focus on two efforts, namely the evolution of multimedia-capable general purpose processors and a more recent effort in developing single component mixed media co-processors. Design considerations that could facilitate the migration of these technologies to a portable integrated media system also are presented.
Design and development of a multimedia database for emergency telemedicine.
Pavlopoulos, S; Berler, A; Kyriacou, E; Koutsouris, D
1998-09-01
Recent studies conclude that early and specialised pre-hospital patient management contributes to emergency cases survival. Recent developments in telecommunication and medical informatics by means of telemedicine can be extremely useful to accomplish such tasks in a cost-effective manner. Along that direction, we have designed a portable device for emergency telemedicine. This device is able to telematically "bring" the expert doctor at the emergency site, have him perform an accurate diagnosis, and subsequently direct the Emergency Medical Technicians on how to treat the patient until he arrives to the hospital. The need for storing and archiving all data being interchanged during the telemedicine sessions is very crucial for clinical, legal and administrative purposes. For this, we have developed a multimedia database able to store and manage the data collected by the AMBULANCE system. The database was equipped with a user-friendly graphical interface to enable use from computer naive users. Furthermore, the database has the possibility to display, in an standard way, ECG's, X-ray, CT and MRI images. The application is password protected with a three-level hierarchy access for users with different privileges. The scope of this application is to enhance the capabilities of the doctor on duty for a more precise and prompt diagnosis. The application has the ability to store audio files related to each emergency case and still images of the scene. Finally, this database can become a useful multimedia tool which will work together with the AMBULANCE portable device, the HIS and the PACS of the hospital. The system has been validated in selected non-critical cases and proved to be functional and successful in enhancing the ability of the doctor's on duty for prompt and accurate diagnosis and specialised pre-hospital treatment.
Tura, A; Badanai, M; Longo, D; Quareni, L
2004-01-01
A portable monitoring device was developed to assist in the management of children with a learning disability. The device was designed for continuous home monitoring of blood oxygen saturation, heart and respiration rates, and patient activity. It could be worn on a belt, while the patient continued normal activities. Data were stored on a multimedia card and automatically transmitted to a PC at prescribed intervals via a Bluetooth wireless link. From the PC the data were transmitted to a Web server, where the information was made available to the staff involved in the patient's care. Preliminary clinical studies were performed with nine patients (four with Down's syndrome, three with cerebral palsy and two with mental retardation). Patients and families considered the device easy to use and to wear. The monitoring device identified events of possible clinical interest. Although it was designed for monitoring children with a learning disability, it may also be useful with other groups, such as elderly people.
Teaching Students with Developmental Disabilities to Operate an iPod Touch[R] to Listen to Music
ERIC Educational Resources Information Center
Kagohara, Debora M.; Sigafoos, Jeff; Achmadi, Donna; van der Meer, Larah; O'Reilly, Mark F.; Lancioni, Giulio E.
2011-01-01
We evaluated an intervention procedure for teaching three students with developmental disabilities to independently operate a portable multimedia device (i.e., an iPod Touch[R]) to listen to music. The intervention procedure included the use of video modeling, which was presented on the same iPod Touch[R] that the students were taught to operate…
Enhancing Icing Training for Pilots Through Web-Based Multimedia
NASA Technical Reports Server (NTRS)
Fletcher, William; Nolan, Gary; Adanich, Emery; Bond, Thomas H.
2006-01-01
The Aircraft Icing Project of the NASA Aviation Safety Program has developed a number of in-flight icing education and training aids designed to increase pilot awareness about the hazards associated with various icing conditions. The challenges and advantages of transitioning these icing training materials to a Web-based delivery are discussed. Innovative Web-based delivery devices increased course availability to pilots and dispatchers while increasing course flexibility and utility. These courses are customizable for both self-directed and instructor-led learning. Part of our goal was to create training materials with enough flexibility to enable Web-based delivery and downloadable portability while maintaining a rich visual multimedia-based learning experience. Studies suggest that using visually based multimedia techniques increases the effectiveness of icing training materials. This paper describes these concepts, gives examples, and discusses the transitional challenges.
Content dependent selection of image enhancement parameters for mobile displays
NASA Astrophysics Data System (ADS)
Lee, Yoon-Gyoo; Kang, Yoo-Jin; Kim, Han-Eol; Kim, Ka-Hee; Kim, Choon-Woo
2011-01-01
Mobile devices such as cellular phones and portable multimedia player with capability of playing terrestrial digital multimedia broadcasting (T-DMB) contents have been introduced into consumer market. In this paper, content dependent image quality enhancement method for sharpness and colorfulness and noise reduction is presented to improve perceived image quality on mobile displays. Human visual experiments are performed to analyze viewers' preference. Relationship between the objective measures and the optimal values of image control parameters are modeled by simple lookup tables based on the results of human visual experiments. Content dependent values of image control parameters are determined based on the calculated measures and predetermined lookup tables. Experimental results indicate that dynamic selection of image control parameters yields better image quality.
A multimedia PDA/PC speech and language therapy tool for patients with aphasia.
Reeves, Nina; Jefferies, Laura; Cunningham, Sally-Jo; Harris, Catherine
2007-01-01
Aphasia is a speech disorder usually caused by stroke or head injury and may involve a variety of communication difficulties. As 30% of stroke sufferers have a persisting speech and language disorder and therapy resources are low, there is clear scope for the development of technology to support patients between therapy sessions. This paper reports on an empirical study which evaluated SoundHelper, a multimedia application to demonstrate how to pronounce target speech sounds. Two prototypes, involving either video or animation, were developed and evaluated with 20 Speech and Language Therapists. Participants responded positively to both, with the video being preferred because of the perceived extra information provided. The potential for the use on portable devices, since internet access is limited in hospitals, is explored in the light of opinions of Augmented and Alternative Communication (AAC) device users in the UK nd Europe who have expressed a strong desire for more use of internet services.
Integrated Technologies: An Approach to Establishing Multimedia Applications for Learning.
ERIC Educational Resources Information Center
Elmore, Garland C.
1992-01-01
Describes a plan for the development of multimedia instruction at Indiana University-Purdue University at Indianapolis (IUPUI). Cooperation between various campus departments is described, including the university libraries. Multimedia systems for permanent installations and portable units are explained, and implications for distance education,…
3D Integration for Wireless Multimedia
NASA Astrophysics Data System (ADS)
Kimmich, Georg
The convergence of mobile phone, internet, mapping, gaming and office automation tools with high quality video and still imaging capture capability is becoming a strong market trend for portable devices. High-density video encode and decode, 3D graphics for gaming, increased application-software complexity and ultra-high-bandwidth 4G modem technologies are driving the CPU performance and memory bandwidth requirements close to the PC segment. These portable multimedia devices are battery operated, which requires the deployment of new low-power-optimized silicon process technologies and ultra-low-power design techniques at system, architecture and device level. Mobile devices also need to comply with stringent silicon-area and package-volume constraints. As for all consumer devices, low production cost and fast time-to-volume production is key for success. This chapter shows how 3D architectures can bring a possible breakthrough to meet the conflicting power, performance and area constraints. Multiple 3D die-stacking partitioning strategies are described and analyzed on their potential to improve the overall system power, performance and cost for specific application scenarios. Requirements and maturity of the basic process-technology bricks including through-silicon via (TSV) and die-to-die attachment techniques are reviewed. Finally, we highlight new challenges which will arise with 3D stacking and an outlook on how they may be addressed: Higher power density will require thermal design considerations, new EDA tools will need to be developed to cope with the integration of heterogeneous technologies and to guarantee signal and power integrity across the die stack. The silicon/wafer test strategies have to be adapted to handle high-density IO arrays, ultra-thin wafers and provide built-in self-test of attached memories. New standards and business models have to be developed to allow cost-efficient assembly and testing of devices from different silicon and technology providers.
Simple video format for mobile applications
NASA Astrophysics Data System (ADS)
Smith, John R.; Miao, Zhourong; Li, Chung-Sheng
2000-04-01
With the advent of pervasive computing, there is a growing demand for enabling multimedia applications on mobile devices. Large numbers of pervasive computing devices, such as personal digital assistants (PDAs), hand-held computer (HHC), smart phones, portable audio players, automotive computing devices, and wearable computers are gaining access to online information sources. However, the pervasive computing devices are often constrained along a number of dimensions, such as processing power, local storage, display size and depth, connectivity, and communication bandwidth, which makes it difficult to access rich image and video content. In this paper, we report on our initial efforts in designing a simple scalable video format with low-decoding and transcoding complexity for pervasive computing. The goal is to enable image and video access for mobile applications such as electronic catalog shopping, video conferencing, remote surveillance and video mail using pervasive computing devices.
Multimedia Courseware in an Open Systems Environment: A Federal Strategy.
ERIC Educational Resources Information Center
Moline, Judi; And Others
The Portable Courseware Project (PORTCO) of the U.S. Department of Defense (DoD) is typical of projects worldwide that require standard software interfaces. This paper articulates the strategy whereby the federal multimedia courseware initiative leverages the open systems movement and the new realities of information technology. The federal…
ERIC Educational Resources Information Center
Doolittle, Peter E.; Mariano, Gina J.
2008-01-01
The present study examined the effects of individual differences in working memory capacity (WMC) on learning from an historical inquiry multimedia tutorial in stationary versus mobile learning environments using a portable digital media player (i.e., iPod). Students with low (n = 44) and high (n = 40) working memory capacity, as measured by the…
MPS Internships in Public Science Education: Sensing the Radio Sky
NASA Astrophysics Data System (ADS)
Blake, Melvin; Castelaz, M. W.; Moffett, D.; Walsh, L.; LaFratta, M.
2006-12-01
The intent of the “Sensing the Radio Sky” program is to teach high school students the concepts and relevance of radio astronomy through presentations in STARLAB portable planetariums. The two year program began in the summer of 2004 and was completed in December 2006. The program involved a team of 12 undergraduate physics and multimedia majors and four faculty mentors from Furman University, University of North Carolina-Asheville and Pisgah Astronomical Research Institute (PARI). One component of the program is the development and production of a projection cylinder for the portable STARLAB planetariums. The cylinder gives a thorough view of the Milky Way and of several other celestial sources in radio wavelengths, yet these images are difficult to perceive without prior knowledge of radio astronomy. Consequently, the Radio Sky team created a multimedia presentation to accompany the cylinder. This multimedia component contains six informative lessons on radio astronomy assembled by the physics interns and numerous illustrations and animations created by the multimedia interns. The cylinder and multimedia components complement each other and provide a unique, thorough, and highly intelligible perspective on radio astronomy. The final draft is complete and will be sent to Learning Technologies, Inc., for marketing to owners of STARLAB planetariums throughout the world. We acknowledge support from the NSF Internship in Public Science Education Program grant number 0324729.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-30
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-694] In the Matter of Certain Multimedia Display and Navigation Devices and Systems, Components Thereof, and Products Containing Same; Notice of... importation of certain multimedia display and navigation devices and systems, components thereof, and products...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-05
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-694] In The Matter of Certain Multimedia Display and Navigation Devices and Systems, Components Thereof, and Products Containing Same; Notice of... multimedia display and navigation devices and systems, components thereof, and products containing same by...
Optical links in handheld multimedia devices
NASA Astrophysics Data System (ADS)
van Geffen, S.; Duis, J.; Miller, R.
2008-04-01
Ever emerging applications in handheld multimedia devices such as mobile phones, laptop computers, portable video games and digital cameras requiring increased screen resolutions are driving higher aggregate bitrates between host processor and display(s) enabling services such as mobile video conferencing, video on demand and TV broadcasting. Larger displays and smaller phones require complex mechanical 3D hinge configurations striving to combine maximum functionality with compact building volumes. Conventional galvanic interconnections such as Micro-Coax and FPC carrying parallel digital data between host processor and display module may produce Electromagnetic Interference (EMI) and bandwidth limitations caused by small cable size and tight cable bends. To reduce the number of signals through a hinge, the mobile phone industry, organized in the MIPI (Mobile Industry Processor Interface) alliance, is currently defining an electrical interface transmitting serialized digital data at speeds >1Gbps. This interface allows for electrical or optical interconnects. Above 1Gbps optical links may offer a cost effective alternative because of their flexibility, increased bandwidth and immunity to EMI. This paper describes the development of optical links for handheld communication devices. A cable assembly based on a special Plastic Optical Fiber (POF) selected for its mechanical durability is terminated with a small form factor molded lens assembly which interfaces between an 850nm VCSEL transmitter and a receiving device on the printed circuit board of the display module. A statistical approach based on a Lean Design For Six Sigma (LDFSS) roadmap for new product development tries to find an optimum link definition which will be robust and low cost meeting the power consumption requirements appropriate for battery operated systems.
NASA Astrophysics Data System (ADS)
Serkan Güllüoüǧlu, Sabri
2013-03-01
This paper outlines the main infrastructure for implicating mobile learning in medicine and present a sample mobile learning application for medical learning within the framework of mobile learning systems. Mobile technology is developing nowadays. In this case it will be useful to develop different learning environments using these innovations in internet based distance education. M-learning makes the most of being on location, providing immediate access, being connected, and acknowledges learning that occurs beyond formal learning settings, in places such as the workplace, home, and outdoors. Central to m-learning is the principle that it is the learner who is mobile rather than the device used to deliver m learning. The integration of mobile technologies into training has made learning more accessible and portable. Mobile technologies make it possible for a learner to have access to a computer and subsequently learning material and activities; at any time and in any place. Mobile devices can include: mobile phone, personal digital assistants (PDAs), personal digital media players (eg iPods, MP3 players), portable digital media players, portable digital multimedia players. Mobile learning (m-learning) is particularly important in medical education, and the major users of mobile devices are in the field of medicine. The contexts and environment in which learning occurs necessitates m-learning. Medical students are placed in hospital/clinical settings very early in training and require access to course information and to record and reflect on their experiences while on the move. As a result of this paper, this paper strives to compare and contrast mobile learning with normal learning in medicine from various perspectives and give insights and advises into the essential characteristics of both for sustaining medical education.
Educational Multimedia Profiling Recommendations for Device-Aware Adaptive Mobile Learning
ERIC Educational Resources Information Center
Moldovan, Arghir-Nicolae; Ghergulescu, Ioana; Muntean, Cristina Hava
2014-01-01
Mobile learning is seeing a fast adoption with the increasing availability and affordability of mobile devices such as smartphones and tablets. As the creation and consumption of educational multimedia content on mobile devices is also increasing fast, educators and mobile learning providers are faced with the challenge to adapt multimedia type…
Design of novel non-contact multimedia controller for disability by using visual stimulus.
Pan, Jeng-Shyang; Lo, Chi-Chun; Tsai, Shang-Ho; Lin, Bor-Shyh
2015-12-01
The design of a novel non-contact multimedia controller is proposed in this study. Nowadays, multimedia controllers are generally used by patients and nursing assistants in the hospital. Conventional multimedia controllers usually involve in manual operation or other physical movements. However, it is more difficult for the disabled patients to operate the conventional multimedia controller by themselves; they might totally depend on others. Different from other multimedia controllers, the proposed system provides a novel concept of controlling multimedia via visual stimuli, without manual operation. The disabled patients can easily operate the proposed multimedia system by focusing on the control icons of a visual stimulus device, where a commercial tablet is used as the visual stimulus device. Moreover, a wearable and wireless electroencephalogram (EEG) acquisition device is also designed and implemented to easily monitor the user's EEG signals in daily life. Finally, the proposed system has been validated. The experimental result shows that the proposed system can effectively measure and extract the EEG feature related to visual stimuli, and its information transfer rate is also good. Therefore, the proposed non-contact multimedia controller exactly provides a good prototype of novel multimedia controlling scheme. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
From alarm systems to smart houses.
Vlaskamp, F J
1992-01-01
The percentage of senior citizens in the Netherlands will rise in coming years. The expected percentage for the year 2010 of persons over age 65 in the total population is 15%. More persons over age 65 than ever before will continue to live in their own environment. Emergency response systems (ERS) can support independent living. The most common type of organization distributing ERS is a small, partly subsidized local alarm organization run by a social welfare office for the elderly. Government subsidy has been reduced in recent years which has motivated small organizations to join together into larger regional organizations in order to get a more solid financial base. On the other hand new semi-commercial and commercial organizations have come into being. These developments are part of the growing importance of home care, leading to more medical applications of ERS. User satisfaction with ERS is high. Portable triggers can enhance the effectiveness of the system. However, many users do not wear the portable trigger when feeling well. Future technical developments will result in multifunctionality of ERS-devices. In the long term the hardware of today will be integrated in a multimedia home terminal replacing the telephone. The portable trigger will remain the only specific hardware at home for ERS.
Interactive Educational Multimedia: Coping with the Need for Increasing Data Storage.
ERIC Educational Resources Information Center
Malhotra, Yogesh; Erickson, Ranel E.
1994-01-01
Discusses the storage requirements for data forms used in interactive multimedia education and presently available storage devices. Highlights include characteristics of educational multimedia; factors determining data storage requirements; storage devices for video and audio needs; laserdiscs and videodiscs; compact discs; magneto-optical drives;…
Portable apparatus for separating sample and detecting target analytes
Renzi, Ronald F.; Wally, Karl; Crocker, Robert W.; Stamps, James F.; Griffiths; Stewart K. ,; Fruetel, Julia A.; Horn, Brent A.; Shokair, Isaac R.; Yee, Daniel D.; VanderNoot, Victoria A.; Wiedenman, Boyd J.; West, Jason A. A.; Ferko, Scott M.
2008-11-18
Portable devices and methods for determining the presence of a target analyte using a portable device are provided. The portable device is preferably hand-held. A sample is injected to the portable device. A microfluidic separation is performed within the portable device and at least one separated component detected by a detection module within the portable device, in embodiments of the invention. A target analyte is identified, based on the separated component, and the presence of the target analyte is indicated on an output interface of the portable device, in accordance with embodiments of the invention.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-01
..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... electronic devices, including wireless communication devices, portable music and data processing devices, and... electronic devices, including wireless communication devices, portable music and data processing devices, and...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-21
... Devices, Portable Music and Data Processing Devices, Computers, and Components Thereof; Institution of... communication devices, portable music and data processing devices, computers, and components thereof by reason... certain wireless communication devices, portable music and data processing devices, computers, and...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-10
..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... importing wireless communication devices, portable music and data processing devices, and tablet computers... certain electronic devices, including wireless communication devices, portable music and data processing...
The Brainarium: An Interactive Immersive Tool for Brain Education, Art, and Neurotherapy
2016-01-01
Recent theoretical and technological advances in neuroimaging techniques now allow brain electrical activity to be recorded using affordable and user-friendly equipment for nonscientist end-users. An increasing number of educators and artists have begun using electroencephalogram (EEG) to control multimedia and live artistic contents. In this paper, we introduce a new concept based on brain computer interface (BCI) technologies: the Brainarium. The Brainarium is a new pedagogical and artistic tool, which can deliver and illustrate scientific knowledge, as well as a new framework for scientific exploration. The Brainarium consists of a portable planetarium device that is being used as brain metaphor. This is done by projecting multimedia content on the planetarium dome and displaying EEG data recorded from a subject in real time using Brain Machine Interface (BMI) technologies. The system has been demonstrated through several performances involving an interaction between the subject controlling the BMI, a musician, and the audience during series of exhibitions and workshops in schools. We report here feedback from 134 participants who filled questionnaires to rate their experiences. Our results show improved subjective learning compared to conventional methods, improved entertainment value, improved absorption into the material being presented, and little discomfort. PMID:27698660
The Brainarium: An Interactive Immersive Tool for Brain Education, Art, and Neurotherapy.
Grandchamp, Romain; Delorme, Arnaud
2016-01-01
Recent theoretical and technological advances in neuroimaging techniques now allow brain electrical activity to be recorded using affordable and user-friendly equipment for nonscientist end-users. An increasing number of educators and artists have begun using electroencephalogram (EEG) to control multimedia and live artistic contents. In this paper, we introduce a new concept based on brain computer interface (BCI) technologies: the Brainarium. The Brainarium is a new pedagogical and artistic tool, which can deliver and illustrate scientific knowledge, as well as a new framework for scientific exploration. The Brainarium consists of a portable planetarium device that is being used as brain metaphor. This is done by projecting multimedia content on the planetarium dome and displaying EEG data recorded from a subject in real time using Brain Machine Interface (BMI) technologies. The system has been demonstrated through several performances involving an interaction between the subject controlling the BMI, a musician, and the audience during series of exhibitions and workshops in schools. We report here feedback from 134 participants who filled questionnaires to rate their experiences. Our results show improved subjective learning compared to conventional methods, improved entertainment value, improved absorption into the material being presented, and little discomfort.
Live broadcast of laparoscopic surgery to handheld computers.
Gandsas, A; McIntire, K; Park, A
2004-06-01
Thanks to advances in computer power and miniaturization technology, portable electronic devices are now being used to assist physicians with various applications that extend far beyond Web browsing or sending e-mail. Handheld computers are used for electronic medical records, billing, coding, and to enable convenient access to electronic journals for reference purposes. The results of diagnostic investigations, such as laboratory results, study reports, and still radiographic pictures, can also be downloaded into portable devices for later view. Handheld computer technology, combined with wireless protocols and streaming video technology, has the added potential to become a powerful educational tool for medical students and residents. The purpose of this study was to assess the feasibility of transferring multimedia data in real time to a handheld computer via a wireless network and displaying them on the computer screens of clients at remote locations. A live laparoscopic splenectomy was transmitted live to eight handheld computers simultaneously through our institution's wireless network. All eight viewers were able to view the procedure and to hear the surgeon's comments throughout the entire duration of the operation. Handheld computer technology can play a key role in surgical education by delivering information to surgical residents or students when they are geographically distant from the actual event. Validation of this new technology by conducting clinical research is still needed to determine whether resident physicians or medical students can benefit from the use of handheld computers.
NSF Internships in Public Science Education: Sensing the Radio Sky
NASA Astrophysics Data System (ADS)
Hund, L.; Boltuch, D.; Fultz, C.; Buck, S.; Smith, T.; Harris, R.; Moffett, D.; LaFratta, M.; Walsh, L.; Castelaz, M. W.
2005-12-01
The intent of the "Sensing the Radio Sky" project is to teach high school students the concepts and relevance of radio astronomy through presentations in STARLAB portable planetariums. The two year project began in the summer of 2004. A total of twelve interns and four faculty mentors from Furman University and UNCA have participated at the Pisgah Astronomical Research Institute to develop the Radio Sky project. The project united physics and multimedia majors and allowed these students to apply their knowledge of different disciplines to a common goal. One component of the project is the development and production of a cylinder to be displayed in portable STARLAB planetariums. The cylinder gives a thorough view of the Milky Way and of several other celestial sources in radio wavelengths, yet these images are difficult to perceive without prior knowledge of radio astronomy. Consequently, the Radio Sky team created a multimedia presentation to accompany the cylinder. This multimedia component contains six informative lessons on radio astronomy assembled by the physics interns and numerous illustrations and animations created by the multimedia interns. The cylinder and multimedia components complement each other and provide a unique, thorough, and highly intelligible perspective on radio astronomy. The project is near completion and the final draft will be sent to Learning Technologies, Inc., for marketing to owners of STARLAB planetariums throughout the world. The development of the Radio Sky project has also provided a template for potential similar projects that examine our universe in different wavelengths, such as gamma ray, x-ray, and infrared. We acknowledge support from the NSF Internship in Public Science Education Program grant number 0324729.
Aids to Computer-Based Multimedia Learning: A Comparison of Human Tutoring and Computer Support
ERIC Educational Resources Information Center
Rodicio, H. Garcia; Sanchez, E.
2012-01-01
Learners are usually provided with support devices because they find it difficult to learn from multimedia presentations. A key question, with no clear answer so far, is how best to present these support devices. One possibility is to insert them into the multimedia presentation (canned support), while another is to have a human agent provide them…
Chen, Hsing-Hsia; Yeh, Mei-Ling; Yang, Hui-Ju
2005-07-01
This study aimed to develop a multimedia video CD (VCD) of patient-controlled analgesia (PCA) and test its effects on pain knowledge and pain relief in patients receiving surgery. This multimedia VCD of PCA was created to convey fundamental knowledge to both patients and their family members and help patients properly utilize PCA devices to relieve pain and improve recovery. The content of multimedia VCD of PCA included pre-admission pain education, introduction of PCA, nursing care procedures, and questions and answers. This study used a quasi-experimental research design to test effects of the multimedia education program in the experimental group of 30 subjects compared to the control subjects of equal number (without the multimedia VCD of PCA). (1) The intervention of multimedia VCD of PCA resulted in a statistically significant difference in pain knowledge between the experimental and control groups. (2) Subjects in the experimental group obtained a better outcome of pain relief compared to control subjects. (3) Subjects in the experimental group indicated that the multimedia VCD of PCA indeed helped them effectively operate their PCA devices to relieve surgery pain. The clinical application of the multimedia VCD of PCA could help patients improve knowledge on pain, learn how to use PCA devices, achieve proper pain relief, and increase effectiveness of recovery activities.
Multimedia courseware in an open-systems environment: a DoD strategy
NASA Astrophysics Data System (ADS)
Welsch, Lawrence A.
1991-03-01
The federal government is about to invest billions of dollars to develop multimedia training materials for delivery on computer-based interactive training systems. Acquisition of a variety of computers and peripheral devices hosting various operating systems and suites of authoring system software will be necessary to facilitate the development of this courseware. There is no single source that will satisfy all needs. Although high-performance, low-cost interactive training hardware is available, the products have proprietary software interfaces. Because the interfaces are proprietary, expensive reprogramming is usually required to adapt such software products to other platforms. This costly reprogramming could be eliminated by adopting standard software interfaces. DoD's Portable Courseware Project (PORTCO) is typical of projects worldwide that require standard software interfaces. This paper articulates the strategy whereby PORTCO leverages the open systems movement and the new realities of information technology. These realities encompass changes in the pace at which new technology becomes available, changes in organizational goals and philosophy, new roles of vendors and users, changes in the procurement process, and acceleration toward open system environments. The PORTCO strategy is applicable to all projects and systems that require open systems to achieve mission objectives. The federal goal is to facilitate the creation of an environment in which high quality portable courseware is available as commercial off-the-shelf products and is competitively supplied by a variety of vendors. In order to achieve this goal a system architecture incorporating standards to meet the users' needs must be established. The Request for Architecture (RFA) developed cooperatively by DoD and the National Institute of Standards and Technology (NIST) will generate the PORTCO systems architecture. This architecture must freely integrate the courseware and authoring software from the lower levels of machine architecture and systems service implementation. In addition, the systems architecture will establish how the application-specific technologies relate to other technologies. Further, a computer-based interactive training applications profile must be developed. This profile, along with the systems architecture derived as a result of the RFA, provides the basis for identifying the needed standards. NIST will then accelerate the development of these standards using, but not restricted to, existing standards activities within established standards forums. The federal multimedia courseware effort has adopted the Interactive Multimedia Association (INA) Recommended Practices for Interactive Video Portability as the baseline for the migration of computer-based interactive training systems to an open systems environment based upon international standards. The PORTCO strategy includes an evolutionary migration to a standards-based, Open System Environments (OSE). An important aspect of this migration strategy is to move to open systems via stepwise evolution rather than via quantum leaps. Another area of concern is that of infrastructure issues, such as maintaining and supporting the technologies required for computer-based interactive training. The federal multimedia initiative will use the RFA-based architecture to differentiate between those technologies that can be maintained and supported by existing infrastructure mechanisms and those that require new mechanisms. Existing infrastructure mechanisms will be used and where infrastructure mechanisms do not exist, the approach will be to place high priority on establishing the appropriate mechanisms. Establishing an infrastructure mechanism is a nontrivial task requiring sustained investment of resources.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-19
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-794] Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... certain electronic devices, including wireless communication devices, portable music and data processing...
21 CFR 868.5440 - Portable oxygen generator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Portable oxygen generator. 868.5440 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5440 Portable oxygen generator. (a) Identification. A portable oxygen generator is a device that is intended to release oxygen for respiratory...
21 CFR 868.5440 - Portable oxygen generator.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Portable oxygen generator. 868.5440 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5440 Portable oxygen generator. (a) Identification. A portable oxygen generator is a device that is intended to release oxygen for respiratory...
21 CFR 868.5440 - Portable oxygen generator.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Portable oxygen generator. 868.5440 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5440 Portable oxygen generator. (a) Identification. A portable oxygen generator is a device that is intended to release oxygen for respiratory...
21 CFR 868.5440 - Portable oxygen generator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Portable oxygen generator. 868.5440 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5440 Portable oxygen generator. (a) Identification. A portable oxygen generator is a device that is intended to release oxygen for respiratory...
21 CFR 868.5440 - Portable oxygen generator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Portable oxygen generator. 868.5440 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5440 Portable oxygen generator. (a) Identification. A portable oxygen generator is a device that is intended to release oxygen for respiratory...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-04
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-794] Certain Electronic Devices, Including Wireless Commmunication Devices, Portable Music and Data Processing Devices, and Tablet Computers... communication devices, portable music and data processing devices, and tablet computers, imported by Apple Inc...
21 CFR 868.5655 - Portable liquid oxygen unit.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Portable liquid oxygen unit. 868.5655 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5655 Portable liquid oxygen unit. (a) Identification. A portable liquid oxygen unit is a portable, thermally insulated container of liquid oxygen that...
21 CFR 868.5655 - Portable liquid oxygen unit.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Portable liquid oxygen unit. 868.5655 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5655 Portable liquid oxygen unit. (a) Identification. A portable liquid oxygen unit is a portable, thermally insulated container of liquid oxygen that...
21 CFR 868.5655 - Portable liquid oxygen unit.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Portable liquid oxygen unit. 868.5655 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5655 Portable liquid oxygen unit. (a) Identification. A portable liquid oxygen unit is a portable, thermally insulated container of liquid oxygen that...
21 CFR 868.5655 - Portable liquid oxygen unit.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Portable liquid oxygen unit. 868.5655 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5655 Portable liquid oxygen unit. (a) Identification. A portable liquid oxygen unit is a portable, thermally insulated container of liquid oxygen that...
21 CFR 868.5655 - Portable liquid oxygen unit.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Portable liquid oxygen unit. 868.5655 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5655 Portable liquid oxygen unit. (a) Identification. A portable liquid oxygen unit is a portable, thermally insulated container of liquid oxygen that...
14 CFR 135.144 - Portable electronic devices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Portable electronic devices. 135.144... Equipment § 135.144 Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no... portable electronic device on any of the following U.S.-registered civil aircraft operating under this part...
14 CFR 135.144 - Portable electronic devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Portable electronic devices. 135.144... Equipment § 135.144 Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no... portable electronic device on any of the following U.S.-registered civil aircraft operating under this part...
14 CFR 125.204 - Portable electronic devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Portable electronic devices. 125.204... Equipment Requirements § 125.204 Portable electronic devices. (a) Except as provided in paragraph (b) of... operation of, any portable electronic device on any U.S.-registered civil aircraft operating under this part...
14 CFR 125.204 - Portable electronic devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Portable electronic devices. 125.204... Equipment Requirements § 125.204 Portable electronic devices. (a) Except as provided in paragraph (b) of... operation of, any portable electronic device on any U.S.-registered civil aircraft operating under this part...
14 CFR 125.204 - Portable electronic devices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Portable electronic devices. 125.204... Equipment Requirements § 125.204 Portable electronic devices. (a) Except as provided in paragraph (b) of... operation of, any portable electronic device on any U.S.-registered civil aircraft operating under this part...
14 CFR 125.204 - Portable electronic devices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Portable electronic devices. 125.204... Equipment Requirements § 125.204 Portable electronic devices. (a) Except as provided in paragraph (b) of... operation of, any portable electronic device on any U.S.-registered civil aircraft operating under this part...
14 CFR 135.144 - Portable electronic devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Portable electronic devices. 135.144... Equipment § 135.144 Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no... portable electronic device on any of the following U.S.-registered civil aircraft operating under this part...
14 CFR 135.144 - Portable electronic devices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Portable electronic devices. 135.144... Equipment § 135.144 Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no... portable electronic device on any of the following U.S.-registered civil aircraft operating under this part...
14 CFR 125.204 - Portable electronic devices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Portable electronic devices. 125.204... Equipment Requirements § 125.204 Portable electronic devices. (a) Except as provided in paragraph (b) of... operation of, any portable electronic device on any U.S.-registered civil aircraft operating under this part...
14 CFR 135.144 - Portable electronic devices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Portable electronic devices. 135.144... Equipment § 135.144 Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no... portable electronic device on any of the following U.S.-registered civil aircraft operating under this part...
Code of Federal Regulations, 2014 CFR
2014-10-01
... channels on which the Mode I device, but not the fixed device, may operate. (d) Geo-location capability.../portable device. A personal/portable TVBD that does not use an internal geo-location capability and access.../portable device. A personal/portable TVBD that uses an internal geo-location capability and access to a TV...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-26
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-745] Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Commission Decision... importation of certain wireless communication devices, portable music and data processing devices, computers...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-25
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-745] Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Commission Decision... importation of certain wireless communication devices, portable music and data processing devices, computers...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-30
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-745] Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Notice of... communication devices, portable music and data processing devices, computers and components thereof by reason of...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-24
... Music and Data Processing Devices, Computers, and Components Thereof; Notice of Receipt of Complaint... complaint entitled Wireless Communication Devices, Portable Music and Data Processing Devices, Computers..., portable music and data processing devices, computers, and components thereof. The complaint names as...
Template-based education toolkit for mobile platforms
NASA Astrophysics Data System (ADS)
Golagani, Santosh Chandana; Esfahanian, Moosa; Akopian, David
2012-02-01
Nowadays mobile phones are the most widely used portable devices which evolve very fast adding new features and improving user experiences. The latest generation of hand-held devices called smartphones is equipped with superior memory, cameras and rich multimedia features, empowering people to use their mobile phones not only as a communication tool but also for entertainment purposes. With many young students showing interest in learning mobile application development one should introduce novel learning methods which may adapt to fast technology changes and introduce students to application development. Mobile phones become a common device, and engineering community incorporates phones in various solutions. Overcoming the limitations of conventional undergraduate electrical engineering (EE) education this paper explores the concept of template-based based education in mobile phone programming. The concept is based on developing small exercise templates which students can manipulate and revise for quick hands-on introduction to the application development and integration. Android platform is used as a popular open source environment for application development. The exercises relate to image processing topics typically studied by many students. The goal is to enable conventional course enhancements by incorporating in them short hands-on learning modules.
Technology Review for Mobile Multimedia Learning Environments
ERIC Educational Resources Information Center
Styliaras, Georgios
2015-01-01
Nowadays, the technological advancement in mobile devices has made possible the development of hypermedia applications that exploit their features. A potential application domain for mobile devices is multimedia educational applications and modules. Such modules may be shared, commented and further reused under other circumstances through the…
Jin, Meihua; Jung, Ji-Young; Lee, Jung-Ryun
2016-10-12
With the arrival of the era of Internet of Things (IoT), Wi-Fi Direct is becoming an emerging wireless technology that allows one to communicate through a direct connection between the mobile devices anytime, anywhere. In Wi-Fi Direct-based IoT networks, all devices are categorized by group of owner (GO) and client. Since portability is emphasized in Wi-Fi Direct devices, it is essential to control the energy consumption of a device very efficiently. In order to avoid unnecessary power consumed by GO, Wi-Fi Direct standard defines two power-saving methods: Opportunistic and Notice of Absence (NoA) power-saving methods. In this paper, we suggest an algorithm to enhance the energy efficiency of Wi-Fi Direct power-saving, considering the characteristics of multimedia video traffic. Proposed algorithm utilizes the statistical distribution for the size of video frames and adjusts the lengths of awake intervals in a beacon interval dynamically. In addition, considering the inter-dependency among video frames, the proposed algorithm ensures that a video frame having high priority is transmitted with higher probability than other frames having low priority. Simulation results show that the proposed method outperforms the traditional NoA method in terms of average delay and energy efficiency.
Jin, Meihua; Jung, Ji-Young; Lee, Jung-Ryun
2016-01-01
With the arrival of the era of Internet of Things (IoT), Wi-Fi Direct is becoming an emerging wireless technology that allows one to communicate through a direct connection between the mobile devices anytime, anywhere. In Wi-Fi Direct-based IoT networks, all devices are categorized by group of owner (GO) and client. Since portability is emphasized in Wi-Fi Direct devices, it is essential to control the energy consumption of a device very efficiently. In order to avoid unnecessary power consumed by GO, Wi-Fi Direct standard defines two power-saving methods: Opportunistic and Notice of Absence (NoA) power-saving methods. In this paper, we suggest an algorithm to enhance the energy efficiency of Wi-Fi Direct power-saving, considering the characteristics of multimedia video traffic. Proposed algorithm utilizes the statistical distribution for the size of video frames and adjusts the lengths of awake intervals in a beacon interval dynamically. In addition, considering the inter-dependency among video frames, the proposed algorithm ensures that a video frame having high priority is transmitted with higher probability than other frames having low priority. Simulation results show that the proposed method outperforms the traditional NoA method in terms of average delay and energy efficiency. PMID:27754315
ERIC Educational Resources Information Center
Adler, Steve
2000-01-01
Explains the use of Adobe Acrobat's Portable Document Format (PDF) for school Web sites and Intranets. Explains the PDF workflow; components for Web-based PDF delivery, including the Web server, preparing content of the PDF files, and the browser; incorporating PDFs into the Web site; incorporating multimedia; and software. (LRW)
21 CFR 868.6250 - Portable air compressor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Portable air compressor. 868.6250 Section 868.6250...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6250 Portable air compressor. (a) Identification. A portable air compressor is a device intended to provide compressed air for medical purposes, e...
21 CFR 868.6250 - Portable air compressor.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Portable air compressor. 868.6250 Section 868.6250...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6250 Portable air compressor. (a) Identification. A portable air compressor is a device intended to provide compressed air for medical purposes, e...
21 CFR 868.6250 - Portable air compressor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Portable air compressor. 868.6250 Section 868.6250...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6250 Portable air compressor. (a) Identification. A portable air compressor is a device intended to provide compressed air for medical purposes, e...
TOPILOT: An Application of New Technology for Distance Learning.
ERIC Educational Resources Information Center
Marks, Ken
1997-01-01
A European Community project is using telematics to serve the educational needs of children whose families are occupational travelers. Portable multimedia materials and a telecommunications system are intended to enable tutors to manage students' learning at a distance. Tutors are concerned about frustration, isolation, and lack of support. (SK)
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-08
... Communication Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Notice of... within the United States after importation of certain wireless communication devices, portable music and... music and data processing devices, computers and components thereof that infringe one or more of claim...
NASA Astrophysics Data System (ADS)
Das, Sayantan; Mandal, Subhamoy; Das, Debnath; Malviya, Richa; Garud, Hrushikesh T.; Ray, Ajoy K.
2016-03-01
In this article we propose a point-of-care screening device for the detection and identification of malaria parasite, plasmodium vivax, plasmodium malaria, plasmodium oval and plasmodium falciparum with a time frame of 15-20 minute. In our device we can provide 97-98% sensitivity for each species as we are using traditional staining methods for detecting the parasites. In addition, as we are also quantifying the parasites, it is possible to provide an accurate estimate about the malarial stage of the patient. The image processing approach increases the total numbers of samples screened by reducing interventions of trained pathologists. This helps in reducing the delays in screening process arising from increased number of potential cases based on seasonal and local variations. The same reduces mortality rate by faster diagnosis and reduced false negative detections (i.e. increased sensitivity). The system can also be integrated with telemedicine platform to obtain inputs from medical practitioners at tertiary healthcare units for diagnostic decision making. Through this paper, we present the functional prototype of this device containing all the integrated parts. The prototype incorporates image acquisition, image processing, storage, multimedia transmission and reporting environment for a low cost PDA device. It is a portable device capable of scanning slides. The acquired image will be preprocessed and processed to get desired output. The device is capable of transmitting and storing pathological information to database placed in a distant pathological center for further consultation.
NASA Astrophysics Data System (ADS)
Kim, Kyung-Su; Lee, Hae-Yeoun; Im, Dong-Hyuck; Lee, Heung-Kyu
Commercial markets employ digital right management (DRM) systems to protect valuable high-definition (HD) quality videos. DRM system uses watermarking to provide copyright protection and ownership authentication of multimedia contents. We propose a real-time video watermarking scheme for HD video in the uncompressed domain. Especially, our approach is in aspect of practical perspectives to satisfy perceptual quality, real-time processing, and robustness requirements. We simplify and optimize human visual system mask for real-time performance and also apply dithering technique for invisibility. Extensive experiments are performed to prove that the proposed scheme satisfies the invisibility, real-time processing, and robustness requirements against video processing attacks. We concentrate upon video processing attacks that commonly occur in HD quality videos to display on portable devices. These attacks include not only scaling and low bit-rate encoding, but also malicious attacks such as format conversion and frame rate change.
NASA Astrophysics Data System (ADS)
Han, Yishi; Luo, Zhixiao; Wang, Jianhua; Min, Zhixuan; Qin, Xinyu; Sun, Yunlong
2014-09-01
In general, context-based adaptive variable length coding (CAVLC) decoding in H.264/AVC standard requires frequent access to the unstructured variable length coding tables (VLCTs) and significant memory accesses are consumed. Heavy memory accesses will cause high power consumption and time delays, which are serious problems for applications in portable multimedia devices. We propose a method for high-efficiency CAVLC decoding by using a program instead of all the VLCTs. The decoded codeword from VLCTs can be obtained without any table look-up and memory access. The experimental results show that the proposed algorithm achieves 100% memory access saving and 40% decoding time saving without degrading video quality. Additionally, the proposed algorithm shows a better performance compared with conventional CAVLC decoding, such as table look-up by sequential search, table look-up by binary search, Moon's method, and Kim's method.
User Experience Evaluation in the Mobile Context
NASA Astrophysics Data System (ADS)
Obrist, Marianna; Meschtscherjakov, Alexander; Tscheligi, Manfred
Multimedia services on mobile devices are becoming increasingly popular. Whereas the mobile phone is the most likely platform for mobile TV, PDAs, portable game consoles, and music players are attractive alternatives. Mobile TV consumption on mobile phones allows new kinds of user experiences, but it also puts designers and researchers in front of new challenges. On the one hand, designers have to take these novel experience potentials into account. On the other hand, the right methods to collect user feedback to further improve services for the mobile context have to be applied. In this chapter the importance of user experience research for mobile TV within the mobile context is highlighted. We present how different experience levels can be evaluated taking different mobile context categories into account. In particular, we discuss the Experience Sampling Method (ESM), which seems to be a fruitful approach for investigating user TV experiences.
14 CFR 121.306 - Portable electronic devices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Portable electronic devices. 121.306... Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate... electronic device on any U.S.-registered civil aircraft operating under this part. (b) Paragraph (a) of this...
14 CFR 121.306 - Portable electronic devices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Portable electronic devices. 121.306... Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate... electronic device on any U.S.-registered civil aircraft operating under this part. (b) Paragraph (a) of this...
14 CFR 121.306 - Portable electronic devices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Portable electronic devices. 121.306... Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate... electronic device on any U.S.-registered civil aircraft operating under this part. (b) Paragraph (a) of this...
14 CFR 121.306 - Portable electronic devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Portable electronic devices. 121.306... Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate... electronic device on any U.S.-registered civil aircraft operating under this part. (b) Paragraph (a) of this...
14 CFR 121.306 - Portable electronic devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Portable electronic devices. 121.306... Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate... electronic device on any U.S.-registered civil aircraft operating under this part. (b) Paragraph (a) of this...
Survey of reconfigurable architectures for multimedia applications
NASA Astrophysics Data System (ADS)
Cervero, T.; López, S.; Callicó, G. M.; Tobajas, F.; de Armas, V.; López, J.; Sarmiento, R.
2009-05-01
In a short period of time, the multimedia sector has quickly progressed trying to overcome the exigencies of the customers in terms of transfer speeds, storage memory, image quality, and functionalities. In order to cope with this stringent situation, different hardware devices have been developed as possible choices. Despite of the fact that not every device is apt for implementing the high computational demands associated to multimedia applications; reconfigurable architectures appear as ideal candidates to achieve these necessities. As a direct consequence, worldwide universities and industries have incremented their research activity into this area, generating an important know-how base. In order to sort all the information generated about this issue, this paper reviews the most recent reconfigurable architectures for multimedia applications. As a result, this paper establishes the benefits and drawbacks of the different dynamically reconfigurable architectures for multimedia applications according to their system-level design.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-17
... Devices and Related Software; Notice of Investigation AGENCY: U.S. International Trade Commission. ACTION... of certain portable electronic devices and related software by reason of infringement of certain... after importation of certain portable electronic devices or related software that infringe one or more...
77 FR 2758 - Certain Portable Communication Devices; Institution of Investigation
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-19
... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-827] Certain Portable Communication Devices... communication devices by reason of infringement of certain claims of U.S. Patent No. 5,926,636 (``the '636... certain portable communication devices that infringe one or more of claims 7-13 and 15 of the '636 patent...
14 CFR 91.21 - Portable electronic devices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...
14 CFR 91.21 - Portable electronic devices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...
14 CFR 91.21 - Portable electronic devices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...
14 CFR 91.21 - Portable electronic devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...
14 CFR 91.21 - Portable electronic devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...
ERIC Educational Resources Information Center
Myslewski, Rik; Garcia, Nathan
1998-01-01
Reviews and compares the following nine laptop computers, focusing on their capabilities for multimedia presentations: Apple Macintosh PowerBook G3, Chem USA ChemBook 9780, Compaq Armada 7792DMT, Dell Inspiron 3000 mZ66xT, Hewlett-Packard OmniBook 3000CTX, IBM ThinkPad 770, Micro Express NP8233MMX, NEC Versa 6260, and Panasonic CF-63. Evaluation…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-06
... INTERNATIONAL TRADE COMMISSION [Docket No 2958] Certain Portable Electronic Communications Devices, Including Mobile Phones and Components Thereof; Correction to Notice of Receipt of Complaint; Solicitation... of complaint entitled Certain Portable Electronic Communications Devices, Including Mobile Phones and...
Code of Federal Regulations, 2010 CFR
2010-07-01
..., fans and other such devices allowed in Government-controlled facilities? 102-74.190 Section 102-74.190... § 102-74.190 Are portable heaters, fans and other such devices allowed in Government-controlled facilities? Federal agencies are prohibited from operating portable heaters, fans, and other such devices in...
A Portable, High Resolution, Surface Measurement Device
NASA Technical Reports Server (NTRS)
Ihlefeld, Curtis M.; Burns, Bradley M.; Youngquist, Robert C.
2012-01-01
A high resolution, portable, surface measurement device has been demonstrated to provide micron-resolution topographical plots. This device was specifically developed to allow in-situ measurements of defects on the Space Shuttle Orbiter windows, but is versatile enough to be used on a wide variety of surfaces. This paper discusses the choice of an optical sensor and then the decisions required to convert a lab bench optical measurement device into an ergonomic portable system. The necessary trade-offs between performance and portability are presented along with a description of the device developed to measure Orbiter window defects.
21 CFR 870.2640 - Portable leakage current alarm.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Portable leakage current alarm. 870.2640 Section 870.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable...
21 CFR 870.2640 - Portable leakage current alarm.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Portable leakage current alarm. 870.2640 Section 870.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable...
Multimedia data repository for the World Wide Web
NASA Astrophysics Data System (ADS)
Chen, Ken; Lu, Dajin; Xu, Duanyi
1998-08-01
This paper introduces the design and implementation of a Multimedia Data Repository served as a multimedia information system, which provides users a Web accessible, platform independent interface to query, browse, and retrieve multimedia data such as images, graphics, audio, video from a large multimedia data repository. By integrating the multimedia DBMS, in which the textual information and samples of the multimedia data is organized and stored, and Web server together into the Microsoft ActiveX Server Framework, users can access the DBMS and query the information by simply using a Web browser at the client-side. The original multimedia data can then be located and transmitted through the Internet from the tertiary storage device, a 400 CDROM optical jukebox at the server-side, to the client-side for further use.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-29
..., Including Mobile Phones, Mobile Tablets, Portable Music Players, and Computers, and Components Thereof... certain electronic devices, including mobile phones, mobile tablets, portable music players, and computers... mobile phones, mobile tablets, portable music players, and computers, and components thereof that...
Daylight control system device and method
Paton, John Douglas
2007-03-13
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Daylight control system, device and method
Paton, John Douglas
2012-08-28
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Daylight control system device and method
Paton, John Douglas
2009-12-01
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-09
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-797] Certain Portable Electronic Devices and Related Software; Determination Not To Review Initial Determination Granting Motion To Amend the... the United States after importation of certain portable electronic devices and related software. 76 FR...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-02
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-701] In the Matter of Certain Electronic Devices, Including Mobile Phones, Portable Music Players, and Computers; Notice of Commission... States after importation of certain electronic devices, including mobile phones, portable music players...
Exploiting spatio-temporal characteristics of human vision for mobile video applications
NASA Astrophysics Data System (ADS)
Jillani, Rashad; Kalva, Hari
2008-08-01
Video applications on handheld devices such as smart phones pose a significant challenge to achieve high quality user experience. Recent advances in processor and wireless networking technology are producing a new class of multimedia applications (e.g. video streaming) for mobile handheld devices. These devices are light weight and have modest sizes, and therefore very limited resources - lower processing power, smaller display resolution, lesser memory, and limited battery life as compared to desktop and laptop systems. Multimedia applications on the other hand have extensive processing requirements which make the mobile devices extremely resource hungry. In addition, the device specific properties (e.g. display screen) significantly influence the human perception of multimedia quality. In this paper we propose a saliency based framework that exploits the structure in content creation as well as the human vision system to find the salient points in the incoming bitstream and adapt it according to the target device, thus improving the quality of new adapted area around salient points. Our experimental results indicate that the adaptation process that is cognizant of video content and user preferences can produce better perceptual quality video for mobile devices. Furthermore, we demonstrated how such a framework can affect user experience on a handheld device.
A Multi-Media CAI Terminal Based upon a Microprocessor with Applications for the Handicapped.
ERIC Educational Resources Information Center
Brebner, Ann; Hallworth, H. J.
The design of the CAI interface described is based on the microprocessor in order to meet three basic requirements for providing appropriate instruction to the developmentally handicapped: (1) portability, so that CAI can be taken into the customary learning environment; (2) reliability; and (3) flexibility, to permit use of new input and output…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-06
... to Amend FINRA Rule 8210 to Require Information Provided via Portable Media Device be Encrypted... to require that information provided via a portable media device pursuant to a request under the rule..., persons often provide information in electronic format using a portable media device such as a CD-ROM, DVD...
Multimedia content description framework
NASA Technical Reports Server (NTRS)
Bergman, Lawrence David (Inventor); Mohan, Rakesh (Inventor); Li, Chung-Sheng (Inventor); Smith, John Richard (Inventor); Kim, Michelle Yoonk Yung (Inventor)
2003-01-01
A framework is provided for describing multimedia content and a system in which a plurality of multimedia storage devices employing the content description methods of the present invention can interoperate. In accordance with one form of the present invention, the content description framework is a description scheme (DS) for describing streams or aggregations of multimedia objects, which may comprise audio, images, video, text, time series, and various other modalities. This description scheme can accommodate an essentially limitless number of descriptors in terms of features, semantics or metadata, and facilitate content-based search, index, and retrieval, among other capabilities, for both streamed or aggregated multimedia objects.
Development of a Portable Knee Rehabilitation Device That Uses Mechanical Loading.
Fitzwater, Daric; Dodge, Todd; Chien, Stanley; Yokota, Hiroki; Anwar, Sohel
2013-12-01
Joint loading is a recently developed mechanical modality, which potentially provides a therapeutic regimen to activate bone formation and prevent degradation of joint tissues. To our knowledge, however, few joint loading devices are available for clinical or point-of-care applications. Using a voice-coil actuator, we developed an electromechanical loading system appropriate for human studies and preclinical trials that should prove both safe and effective. Two specific tasks for this loading system were development of loading conditions (magnitude and frequency) suitable for humans, and provision of a convenient and portable joint loading apparatus. Desktop devices have been previously designed to evaluate the effects of various loading conditions using small and large animals. However, a portable knee loading device is more desirable from a usability point of view. In this paper, we present such a device that is designed to be portable, providing a compact, user-friendly loader. The portable device was employed to evaluate its capabilities using a human knee model. The portable device was characterized for force-pulse width modulation duty cycle and loading frequency properties. The results demonstrate that the device is capable of producing the necessary magnitude of forces at appropriate frequencies to promote the stimulation of bone growth and which can be used in clinical studies for further evaluations.
ERIC Educational Resources Information Center
Zhou, Ninger; Yadav, Aman
2017-01-01
The use of multimedia story applications on touch-interactive mobile devices has become prevalent in early education settings. However, despite the promise of multimedia story applications for early learning outcomes, there has been a dearth of research on the educational benefits of such tools, and whether their effects can be strengthened with…
Portable modular detection system
Brennan, James S [Rodeo, CA; Singh, Anup [Danville, CA; Throckmorton, Daniel J [Tracy, CA; Stamps, James F [Livermore, CA
2009-10-13
Disclosed herein are portable and modular detection devices and systems for detecting electromagnetic radiation, such as fluorescence, from an analyte which comprises at least one optical element removably attached to at least one alignment rail. Also disclosed are modular detection devices and systems having an integrated lock-in amplifier and spatial filter and assay methods using the portable and modular detection devices.
2006 Pathogen and Toxin Concentration Systems for Water Monitoring
2012-07-24
design and construct a compact, portable automated device enabling the simultaneous concentration of protozoa , bacteria, bacterial spores, algae and...portable automated device enabling the simultaneous concentration of protozoa , bacteria, bacterial spores, algae and viruses from large volumes of various...construct a compact, portable automated device enabling the simultaneous concentration of protozoa , bacteria, bacterial spores, algae and viruses
Using a Multimedia Tool to Improve Cardiac Auscultation Knowledge and Skills
Stern, David T; Mangrulkar, Rajesh S; Gruppen, Larry D; Lang, Angela L; Grum, Cyril M; Judge, Richard D
2001-01-01
OBJECTIVE Today's medical school graduates have significant deficits in physical examination skills. Medical educators have been searching for methods to effectively teach and maintain these skills in students. The objective of this study was to determine if an auscultation curriculum centered on a portable multimedia CD-ROM was effective in producing and maintaining significant gains in cardiac auscultatory skills. DESIGN Controlled cohort study PARTICIPANTS All 168 third-year medical students at 1 medical school in an academic medical center. INTERVENTIONS Students were tested before and after exposure to 1 or more elements of the auscultation curriculum: teaching on ward/clinic rotations, CD-ROM comprehensive cases with follow-up seminars, and a CD-ROM 20-case miniseries. The primary outcome measures were student performance on a 10-item test of auscultation skill (listening and identifying heart sound characteristics) and a 30-item test of auscultation knowledge (factual questions about auscultation). A subset of students was tested for attenuation effects 9 or 12 months after the intervention. RESULTS Compared with the control group (1 month clinical rotation alone), students who were also exposed to the CD-ROM 20-case miniseries had significant improvements in auscultation skills scores (P < .05), but not knowledge. Additional months of clerkship, comprehensive CD-ROM cases, and follow-up seminars increased auscultation knowledge beyond the miniseries alone (P < .05), but did not further improve auscultation skills. Students' auscultation knowledge diminished one year after the intervention, but auscultation skills did not. CONCLUSION In addition to the standard curriculum of ward and conference teaching, portable multimedia tools may help improve quality of physical examination skills. PMID:11722691
Using a multimedia tool to improve cardiac auscultation knowledge and skills.
Stern, D T; Mangrulkar, R S; Gruppen, L D; Lang, A L; Grum, C M; Judge, R D
2001-11-01
Today's medical school graduates have significant deficits in physical examination skills. Medical educators have been searching for methods to effectively teach and maintain these skills in students. The objective of this study was to determine if an auscultation curriculum centered on a portable multimedia CD-ROM was effective in producing and maintaining significant gains in cardiac auscultatory skills. Controlled cohort study. All 168 third-year medical students at 1 medical school in an academic medical center. Students were tested before and after exposure to 1 or more elements of the auscultation curriculum: teaching on ward/clinic rotations, CD-ROM comprehensive cases with follow-up seminars, and a CD-ROM 20-case miniseries. The primary outcome measures were student performance on a 10-item test of auscultation skill (listening and identifying heart sound characteristics) and a 30-item test of auscultation knowledge (factual questions about auscultation). A subset of students was tested for attenuation effects 9 or 12 months after the intervention. Compared with the control group (1 month clinical rotation alone), students who were also exposed to the CD-ROM 20-case miniseries had significant improvements in auscultation skills scores (P < .05), but not knowledge. Additional months of clerkship, comprehensive CD-ROM cases, and follow-up seminars increased auscultation knowledge beyond the miniseries alone (P < .05), but did not further improve auscultation skills. Students' auscultation knowledge diminished one year after the intervention, but auscultation skills did not. In addition to the standard curriculum of ward and conference teaching, portable multimedia tools may help improve quality of physical examination skills.
ERIC Educational Resources Information Center
Cooper, Paul K.
2017-01-01
There has been a significant growth of portable devices capable of storing both personal data as well as sensitive organizational data. This growth of these portable devices has led to an increased threat of cyber-criminal activity. The purpose of this study was to gain a better understanding of security threats to the data assets of organizations…
21 CFR 870.2640 - Portable leakage current alarm.
Code of Federal Regulations, 2014 CFR
2014-04-01
... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if...
21 CFR 870.2640 - Portable leakage current alarm.
Code of Federal Regulations, 2013 CFR
2013-04-01
... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if...
21 CFR 870.2640 - Portable leakage current alarm.
Code of Federal Regulations, 2012 CFR
2012-04-01
... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if...
A Trusted Portable Computing Device
NASA Astrophysics Data System (ADS)
Ming-wei, Fang; Jun-jun, Wu; Peng-fei, Yu; Xin-fang, Zhang
A trusted portable computing device and its security mechanism were presented to solve the security issues, such as the attack of virus and Trojan horse, the lost and stolen of storage device, in mobile office. It used smart card to build a trusted portable security base, virtualization to create a secure virtual execution environment, two-factor authentication mechanism to identify legitimate users, and dynamic encryption to protect data privacy. The security environment described in this paper is characteristic of portability, security and reliability. It can meet the security requirement of mobile office.
Multimedia information processing in the SWAN mobile networked computing system
NASA Astrophysics Data System (ADS)
Agrawal, Prathima; Hyden, Eoin; Krzyzanowsji, Paul; Srivastava, Mani B.; Trotter, John
1996-03-01
Anytime anywhere wireless access to databases, such as medical and inventory records, can simplify workflow management in a business, and reduce or even eliminate the cost of moving paper documents. Moreover, continual progress in wireless access technology promises to provide per-user bandwidths of the order of a few Mbps, at least in indoor environments. When combined with the emerging high-speed integrated service wired networks, it enables ubiquitous and tetherless access to and processing of multimedia information by mobile users. To leverage on this synergy an indoor wireless network based on room-sized cells and multimedia mobile end-points is being developed at AT&T Bell Laboratories. This research network, called SWAN (Seamless Wireless ATM Networking), allows users carrying multimedia end-points such as PDAs, laptops, and portable multimedia terminals, to seamlessly roam while accessing multimedia data streams from the wired backbone network. A distinguishing feature of the SWAN network is its use of end-to-end ATM connectivity as opposed to the connectionless mobile-IP connectivity used by present day wireless data LANs. This choice allows the wireless resource in a cell to be intelligently allocated amongst various ATM virtual circuits according to their quality of service requirements. But an efficient implementation of ATM in a wireless environment requires a proper mobile network architecture. In particular, the wireless link and medium-access layers need to be cognizant of the ATM traffic, while the ATM layers need to be cognizant of the mobility enabled by the wireless layers. This paper presents an overview of SWAN's network architecture, briefly discusses the issues in making ATM mobile and wireless, and describes initial multimedia applications for SWAN.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-12
... Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and..., portable music and data processing devices, computers and components thereof. The complaint names as...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-05
... Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data, and Tablet..., portable music and data processing devices, and tablet computers. The complaint names as respondent Apple...
Britton, J
2007-01-01
Portable medical devices represent an important resource for assisting healthcare delivery. The movement of portable devices often results in them being unavailable when needed. Tracking equipment using radiofrequency identification technology/devices (RFID) may provide a promising solution to the problems encountered in locating portable equipment. An RFID technology trial was undertaken at Royal Alexandra Hospital, Paisley. This involved the temporary installation of three active readers and attaching actively transmitting radio frequency tags to different portable medical devices. The active readers and computer system were linked using a bespoke data network. Tags and readers from two separate manufacturers were tested. Reliability difficulties were encountered when testing the technology from the first manufacturer, probably due to the casing of the medical device interfering with the signal from the tag. Improved results were obtained when using equipment from the second manufacturer with an overall error rate of 12.3%. Tags from this manufacturer were specifically designed to overcome problems observed with the first system tested. Findings from this proof of concept trial suggest that RFID technology could be used to track the location of equipment in a hospital.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-15
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-745] Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Notice of Request for Statements on the Public Interest AGENCY: U.S. International Trade Commission. ACTION: Notice...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-29
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-856] Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers, and Components Thereof AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that the U.S. International...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-14
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-771] In the Matter of Certain Electronic Devices, Including Mobile Phones, Mobile Tablets, Portable Music Players, and Computers, and Components... certain mobile phones, mobile tablets, portable music players, and computers. 76 FR 24051 (Apr. 29, 2011...
NASA Astrophysics Data System (ADS)
Brumana, R.; Santana Quintero, M.; Barazzetti, L.; Previtali, M.; Banfi, F.; Oreni, D.; Roels, D.; Roncoroni, F.
2015-08-01
Landscapes are dynamic entities, stretching and transforming across space and time, and need to be safeguarded as living places for the future, with interaction of human, social and economic dimensions. To have a comprehensive landscape evaluation several open data are needed, each one characterized by its own protocol, service interface, limiting or impeding this way interoperability and their integration. Indeed, nowadays the development of websites targeted to landscape assessment and touristic purposes requires many resources in terms of time, cost and IT skills to be implemented at different scales. For this reason these applications are limited to few cases mainly focusing on worldwide known touristic sites. The capability to spread the development of web-based multimedia virtual museum based on geospatial data relies for the future being on the possibility to discover the needed geo-spatial data through a single point of access in an homogenous way. In this paper the proposed innovative approach may facilitate the access to open data in a homogeneous way by means of specific components (the brokers) performing interoperability actions required to interconnect heterogeneous data sources. In the specific case study here analysed it has been implemented an interface to migrate a geo-swat chart based on local and regional geographic information into an user friendly Google Earth©-based infrastructure, integrating ancient cadastres and modern cartography, accessible by professionals and tourists via web and also via portable devices like tables and smartphones. The general aim of this work on the case study on the Lake of Como (Tremezzina municipality), is to boost the integration of assessment methodologies with digital geo-based technologies of map correlation for the multimedia ecomuseum system accessible via web. The developed WebGIS system integrates multi-scale and multi-temporal maps with different information (cultural, historical, landscape levels) represented by thematic icons allowing to transfer the richness of the landscape value to both tourists and professionals.
LeMoyne, Robert; Mastroianni, Timothy
2015-01-01
Smartphones and portable media devices are both equipped with sensor components, such as accelerometers. A software application enables these devices to function as a robust wireless accelerometer platform. The recorded accelerometer waveform can be transmitted wireless as an e-mail attachment through connectivity to the Internet. The implication of such devices as a wireless accelerometer platform is the experimental and post-processing locations can be placed anywhere in the world. Gait was quantified by mounting a smartphone or portable media device proximal to the lateral malleolus of the ankle joint. Attributes of the gait cycle were quantified with a considerable accuracy and reliability. The patellar tendon reflex response was quantified by using the device in tandem with a potential energy impact pendulum to evoke the patellar tendon reflex. The acceleration waveform maximum acceleration feature of the reflex response displayed considerable accuracy and reliability. By mounting the smartphone or portable media device to the dorsum of the hand through a glove, Parkinson's disease hand tremor was quantified and contrasted with significance to a non-Parkinson's disease steady hand control. With the methods advocated in this chapter, any aspect of human movement may be quantified through smartphones or portable media devices and post-processed anywhere in the world. These wearable devices are anticipated to substantially impact the biomedical and healthcare industry.
An IMS-Based Middleware Solution for Energy-Efficient and Cost-Effective Mobile Multimedia Services
NASA Astrophysics Data System (ADS)
Bellavista, Paolo; Corradi, Antonio; Foschini, Luca
Mobile multimedia services have recently become of extreme industrial relevance due to the advances in both wireless client devices and multimedia communications. That has motivated important standardization efforts, such as the IP Multimedia Subsystem (IMS) to support session control, mobility, and interoperability in all-IP next generation networks. Notwithstanding the central role of IMS in novel mobile multimedia, the potential of IMS-based service composition for the development of new classes of ready-to-use, energy-efficient, and cost-effective services is still widely unexplored. The paper proposes an original solution for the dynamic and standard-compliant redirection of incoming voice calls towards WiFi-equipped smart phones. The primary design guideline is to reduce energy consumption and service costs for the final user by automatically switching from the 3G to the WiFi infrastructure whenever possible. The proposal is fully compliant with the IMS standard and exploits the recently released IMS presence service to update device location and current communication opportunities. The reported experimental results point out that our solution, in a simple way and with full compliance with state-of-the-art industrially-accepted standards, can significantly increase battery lifetime without negative effects on call initiation delay.
30 CFR 75.1100-1 - Type and quality of firefighting equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
... extinguishing capacity equivalent to that of a portable water car. (d) Portable foam-generating machines or devices: A portable foam-generating machine or device shall have facilities and equipment for supplying the machine with 30 gallons of water per minute at 30 pounds per square inch for a period of 35...
30 CFR 75.1100-1 - Type and quality of firefighting equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... extinguishing capacity equivalent to that of a portable water car. (d) Portable foam-generating machines or devices: A portable foam-generating machine or device shall have facilities and equipment for supplying the machine with 30 gallons of water per minute at 30 pounds per square inch for a period of 35...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-28
..., Including Mobile Phones, Portable Music Players, and Computers; Notice of Investigation AGENCY: U.S... music players, and computers, by reason of infringement of certain claims of U.S. Patent Nos. 6,714,091... importation of certain electronic devices, including mobile phones, portable music players, or computers that...
Smart portable rehabilitation devices.
Mavroidis, Constantinos; Nikitczuk, Jason; Weinberg, Brian; Danaher, Gil; Jensen, Katherine; Pelletier, Philip; Prugnarola, Jennifer; Stuart, Ryan; Arango, Roberto; Leahey, Matt; Pavone, Robert; Provo, Andrew; Yasevac, Dan
2005-07-12
The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s). In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Laboratory tests of the devices demonstrated that they were able to meet their design objectives. The prototypes of portable rehabilitation devices presented here did demonstrate that these concepts are capable of the performance their commercially available but non-portable counterparts exhibit. Smart, portable devices with the ability for real time monitoring and adjustment open a new era in rehabilitation where the recovery process could be dramatically improved.
Smart portable rehabilitation devices
Mavroidis, Constantinos; Nikitczuk, Jason; Weinberg, Brian; Danaher, Gil; Jensen, Katherine; Pelletier, Philip; Prugnarola, Jennifer; Stuart, Ryan; Arango, Roberto; Leahey, Matt; Pavone, Robert; Provo, Andrew; Yasevac, Dan
2005-01-01
Background The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s). Methods In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Results Laboratory tests of the devices demonstrated that they were able to meet their design objectives. The prototypes of portable rehabilitation devices presented here did demonstrate that these concepts are capable of the performance their commercially available but non-portable counterparts exhibit. Conclusion Smart, portable devices with the ability for real time monitoring and adjustment open a new era in rehabilitation where the recovery process could be dramatically improved. PMID:16011801
Outsourcing Security Services for Low Performance Portable Devices
NASA Astrophysics Data System (ADS)
Szentgyörgyi, Attila; Korn, András
The number of portable devices using wireless network technologies is on the rise. Some of these devices are incapable of, or at a disadvantage at using secure Internet services, because secure communication often requires comparatively high computing capacity. In this paper, we propose a solution which can be used to offer secure network services for low performance portable devices without severely degrading data transmission rates. We also show that using our approach these devices can utilize some secure network services which were so far unavailable to them due to a lack of software support. In order to back up our claims, we present performance measurement results obtained in a test network.
Personal, Portable, Multifunction-Devices and School Libraries
ERIC Educational Resources Information Center
Weaver, Anne
2010-01-01
To maximise learning value from one-to-one programs in schools, computing devices need to be personal, portable and multifunctional. It is likely that shared devices will not be as effective. The increased access provided by one-to-one devices creates great opportunities for school librarians to support their school technology directions and to…
Deflectometry using portable devices
NASA Astrophysics Data System (ADS)
Butel, Guillaume P.; Smith, Greg A.; Burge, James H.
2015-02-01
Deflectometry is a powerful metrology technique that uses off-the-shelf equipment to achieve nanometer-level accuracy surface measurements. However, there is no portable device to quickly measure eyeglasses, lenses, or mirrors. We present an entirely portable new deflectometry technique that runs on any Android™ smartphone with a front-facing camera. Our technique overcomes some specific issues of portable devices like screen nonlinearity and automatic gain control. We demonstrate our application by measuring an amateur telescope mirror and simulating a measurement of the faulty Hubble Space Telescope primary mirror. Our technique can, in less than 1 min, measure surface errors with accuracy up to 50 nm RMS, simply using a smartphone.
Design of portable electrocardiogram device using DSO138
NASA Astrophysics Data System (ADS)
Abuzairi, Tomy; Matondang, Josef Stevanus; Purnamaningsih, Retno Wigajatri; Basari, Ratnasari, Anita
2018-02-01
Cardiovascular disease has been one of the leading causes of sudden cardiac deaths in many countries, covering Indonesia. Electrocardiogram (ECG) is a medical test to detect cardiac abnormalities by measuring the electrical activity generated by the heart, as the heart contracts. By using ECG, we can observe anomaly at the time of heart abnormalities. In this paper, design of portable ECG device is presented. The portable ECG device was designed to easily use in the village clinic or houses, due to the small size device and other benefits. The device was designed by using four units: (1) ECG electrode; (2) ECG analog front-end; (3) DSO138; and (4) battery. To create a simple electrode system in the portable ECG, 1-lead ECG with two electrodes were applied. The analog front-end circuitry consists of three integrated circuits, an instrumentation amplifier AD820AN, a low noise operational amplifier OPA134, and a low offset operational amplifier TL082. Digital ECG data were transformed to graphical data on DSO138. The results show that the portable ECG is successfully read the signal from 1-lead ECG system.
Property-Based Monitoring of Analog and Mixed-Signal Systems
NASA Astrophysics Data System (ADS)
Havlicek, John; Little, Scott; Maler, Oded; Nickovic, Dejan
In the recent past, there has been a steady growth of the market for consumer embedded devices such as cell phones, GPS and portable multimedia systems. In embedded systems, digital, analog and software components are combined on a single chip, resulting in increasingly complex designs that introduce richer functionality on smaller devices. As a consequence, the potential insertion of errors into a design becomes higher, yielding an increasing need for automated analog and mixed-signal validation tools. In the purely digital setting, formal verification based on properties expressed in industrial specification languages such as PSL and SVA is nowadays successfully integrated in the design flow. On the other hand, the validation of analog and mixed-signal systems still largely depends on simulation-based, ad-hoc methods. In this tutorial, we consider some ingredients of the standard verification methodology that can be successfully exported from digital to analog and mixed-signal setting, in particular property-based monitoring techniques. Property-based monitoring is a lighter approach to the formal verification, where the system is seen as a "black-box" that generates sets of traces, whose correctness is checked against a property, that is its high-level specification. Although incomplete, monitoring is effectively used to catch faults in systems, without guaranteeing their full correctness.
Portable Horizontal-Drilling And Positioning Device
NASA Technical Reports Server (NTRS)
Smigocki, Edmund; Johnson, Clarence
1988-01-01
Portable horizontal-drilling and positioning device, constructed mainly of off-the-shelf components, accurately drills horizontal small holes in irregularly shaped objects. Holes precisely placed and drilled in objects that cannot be moved to shop area. New device provides three axes of movement while maintaining horizontal drilling.
21 CFR 868.6250 - Portable air compressor.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) Identification. A portable air compressor is a device intended to provide compressed air for medical purposes, e.g., to drive ventilators and other respiratory devices. (b) Classification. Class II (performance...
21 CFR 868.6250 - Portable air compressor.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) Identification. A portable air compressor is a device intended to provide compressed air for medical purposes, e.g., to drive ventilators and other respiratory devices. (b) Classification. Class II (performance...
Embedded Data Processor and Portable Computer Technology testbeds
NASA Technical Reports Server (NTRS)
Alena, Richard; Liu, Yuan-Kwei; Goforth, Andre; Fernquist, Alan R.
1993-01-01
Attention is given to current activities in the Embedded Data Processor and Portable Computer Technology testbed configurations that are part of the Advanced Data Systems Architectures Testbed at the Information Sciences Division at NASA Ames Research Center. The Embedded Data Processor Testbed evaluates advanced microprocessors for potential use in mission and payload applications within the Space Station Freedom Program. The Portable Computer Technology (PCT) Testbed integrates and demonstrates advanced portable computing devices and data system architectures. The PCT Testbed uses both commercial and custom-developed devices to demonstrate the feasibility of functional expansion and networking for portable computers in flight missions.
Special Considerations for Networking Multimedia CD-ROM Titles.
ERIC Educational Resources Information Center
Wolfe, Janet L.
1994-01-01
Discusses issues to be considered when networking multimedia CD-ROMs. Topics addressed include CD-ROM networking software; license concerns; configurations for CD-ROM servers; data caching; SCSI devices; CD-ROM drives; workstation configurations, including minimum requirements for five popular CD-ROM titles; and system setup troubleshooting tips.…
Design of Multimedia Situational Awareness Training for Pilots.
ERIC Educational Resources Information Center
Homan, Willem J.
1998-01-01
A recent development in aviation is the personal computer aviation training device (PC-ATD). This article provides an overview of instructional multimedia for pilot training, specifically for enhancing situational awareness (SA), a state in which a pilot's perceptions match reality. Discusses how PC-based trainers can be used to familiarize pilots…
System Control Applications of Low-Power Radio Frequency Devices
NASA Astrophysics Data System (ADS)
van Rensburg, Roger
2017-09-01
This paper conceptualizes a low-power wireless sensor network design for application employment to reduce theft of portable computer devices used in educational institutions today. The aim of this study is to design and develop a reliable and robust wireless network that can eradicate accessibility of a device’s human interface. An embedded system supplied by an energy harvesting source, installed on the portable computer device, may represent one of multiple slave nodes which request regular updates from a standalone master station. A portable computer device which is operated in an undesignated area or in a field perimeter where master to slave communication is restricted, indicating a possible theft scenario, will initiate a shutdown of its operating system and render the device unusable. Consequently, an algorithm in the device firmware may ensure the necessary steps are executed to track the device, irrespective whether the device is enabled. Design outcomes thus far indicate that a wireless network using low-power embedded hardware, is feasible for anti-theft applications. By incorporating one of the latest Bluetooth low-energy, ANT+, ZigBee or Thread wireless technologies, an anti-theft system may be implemented that has the potential to reduce major portable computer device theft in institutions of digitized learning.
Portable biochip scanner device
Perov, Alexander; Sharonov, Alexei; Mirzabekov, Andrei D.
2002-01-01
A portable biochip scanner device used to detect and acquire fluorescence signal data from biological microchips (biochips) is provided. The portable biochip scanner device employs a laser for emitting an excitation beam. An optical fiber delivers the laser beam to a portable biochip scanner. A lens collimates the laser beam, the collimated laser beam is deflected by a dichroic mirror and focused by an objective lens onto a biochip. The fluorescence light from the biochip is collected and collimated by the objective lens. The fluorescence light is delivered to a photomultiplier tube (PMT) via an emission filter and a focusing lens. The focusing lens focuses the fluorescence light into a pinhole. A signal output of the PMT is processed and displayed.
Light Weight Portable Plasma Medical Device - Plasma Engineering Research Laboratory
2011-10-01
Millennial Student. 15. Thiyagarajan, M. (2011). Portable Plasma Biomedical Device for Cancer Treatment. Irvine, California: ASME Emerging...American Society of Mechanical Engineers Sigma Xi Toastmasters International Club MIT Entrepreneur Club Eta Kappa Nu Tau Beta Pi Institute of...Learning Environment. Corpus Christi, TX: TAMUCC 1st Faculty Symposium: Course Design for the Millennial Student. Thiyagarajan, M. (2011). Portable
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-10
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health Prospective Grant of Start-up Exclusive Evaluation License: Portable Device and Method for Detecting Hematomas AGENCY: National... device and method for detecting hematomas based on near infrared light emitted perpendicularly into a...
21 CFR 878.4680 - Nonpowered, single patient, portable suction apparatus.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nonpowered, single patient, portable suction apparatus. 878.4680 Section 878.4680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878...
21 CFR 878.4680 - Nonpowered, single patient, portable suction apparatus.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nonpowered, single patient, portable suction apparatus. 878.4680 Section 878.4680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878...
21 CFR 878.4680 - Nonpowered, single patient, portable suction apparatus.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nonpowered, single patient, portable suction apparatus. 878.4680 Section 878.4680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878...
DOT National Transportation Integrated Search
1974-06-01
This evaluation report examines use in the field of portable breath test (PBT) devices by police in Hennepin County, Minnesota. Thirteen Brog-Warner J2 and J2A-200 "ALERT" devices were deployed by seven enforcement agencies. This report is presented ...
Strategies for Individualizing Typing Instruction
ERIC Educational Resources Information Center
Quible, Zane K.
1978-01-01
Strategies to individualize instruction in typewriting classes discussed in the article are the multimedia approach, mechanical pacing devices, computer-assisted instruction, learning activity packages, and several project-type devices. (MF)
Portable device for detection of petit mal epilepsy
NASA Technical Reports Server (NTRS)
Smith, R. G.; Houge, J. C.; Webster, J. G.
1979-01-01
A portable device that analyzes the electroencephalogram to determine if petit mal epilepsy waveforms are present is developed and tested. Clinicians should find it useful in diagnosing seizure activity of their patients. The micropower, battery-operated, portable device indicates a seizure has occurred if three criteria are satisfied: (1) frequencies of 2.5-7 Hz, (2) large-amplitude waves, and (3) minimum number of waves per second. Levels and counts are adjustable, thus insuring high reliability against noise artifacts and permitting each subject to be individually fitted. The device has shown promise in giving the patient a possible mechanism of seizure control or suppression.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-01
... Certain Electronic Devices, Including Mobile Phones, Mobile Tablets, Portable Music Players, and Computers... importation of certain electronic devices, including mobile phones, mobile tablets, portable music players...
NASA Astrophysics Data System (ADS)
Ponomarev, Vasily
SPLDESS development with the elements of a multimedia illustration of traditional hypertext search results by Internet search engine provides research of information propagation innovative effect during the public access information-recruiting networks of information kiosks formation at the experimental stage with the mirrors at the constantly updating portal for Internet users. Author of this publication put the emphasis on a condition of pertinent search engine results of the total answer by the user inquiries, that provide the politically correct and not usurping socially-network data mining effect at urgent monitoring. Development of the access by devices of the new communication types with the newest technologies of data transmission, multimedia and an information exchange from the first innovation line usage support portal is presented also (including the device of social-psycho-linguistic determination according the author's conception).
Voice and gesture-based 3D multimedia presentation tool
NASA Astrophysics Data System (ADS)
Fukutake, Hiromichi; Akazawa, Yoshiaki; Okada, Yoshihiro
2007-09-01
This paper proposes a 3D multimedia presentation tool that allows the user to manipulate intuitively only through the voice input and the gesture input without using a standard keyboard or a mouse device. The authors developed this system as a presentation tool to be used in a presentation room equipped a large screen like an exhibition room in a museum because, in such a presentation environment, it is better to use voice commands and the gesture pointing input rather than using a keyboard or a mouse device. This system was developed using IntelligentBox, which is a component-based 3D graphics software development system. IntelligentBox has already provided various types of 3D visible, reactive functional components called boxes, e.g., a voice input component and various multimedia handling components. IntelligentBox also provides a dynamic data linkage mechanism called slot-connection that allows the user to develop 3D graphics applications by combining already existing boxes through direct manipulations on a computer screen. Using IntelligentBox, the 3D multimedia presentation tool proposed in this paper was also developed as combined components only through direct manipulations on a computer screen. The authors have already proposed a 3D multimedia presentation tool using a stage metaphor and its voice input interface. This time, we extended the system to make it accept the user gesture input besides voice commands. This paper explains details of the proposed 3D multimedia presentation tool and especially describes its component-based voice and gesture input interfaces.
Identifying people from gait pattern with accelerometers
NASA Astrophysics Data System (ADS)
Ailisto, Heikki J.; Lindholm, Mikko; Mantyjarvi, Jani; Vildjiounaite, Elena; Makela, Satu-Marja
2005-03-01
Protecting portable devices is becoming more important, not only because of the value of the devices themselves, but for the value of the data in them and their capability for transactions, including m-commerce and m-banking. An unobtrusive and natural method for identifying the carrier of portable devices is presented. The method uses acceleration signals produced by sensors embedded in the portable device. When the user carries the device, the acceleration signal is compared with the stored template signal. The method consists of finding individual steps, normalizing and averaging them, aligning them with the template and computing cross-correlation, which is used as a measure of similarity. Equal Error Rate of 6.4% is achieved in tentative experiments with 36 test subjects.
DAVE: A plug and play model for distributed multimedia application development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mines, R.F.; Friesen, J.A.; Yang, C.L.
1994-07-01
This paper presents a model being used for the development of distributed multimedia applications. The Distributed Audio Video Environment (DAVE) was designed to support the development of a wide range of distributed applications. The implementation of this model is described. DAVE is unique in that it combines a simple ``plug and play`` programming interface, supports both centralized and fully distributed applications, provides device and media extensibility, promotes object reuseability, and supports interoperability and network independence. This model enables application developers to easily develop distributed multimedia applications and create reusable multimedia toolkits. DAVE was designed for developing applications such as videomore » conferencing, media archival, remote process control, and distance learning.« less
"Urgency tip": a portable patient-activated device for objective measurement of urinary urgency.
Kobayashi, Hideki; Araki, Isao; Tsuchida, Takayuki; Zakoji, Hidenori; Mikami, Yuki; Takeda, Masayuki; Kiyohiro, Noriaki
2007-03-01
For clinical practice and research of overactive bladder syndrome, it is essential to evaluate urgency symptoms in daily life. We have developed a portable patient-activated device to record bladder sensations. This electronic device is pocket-size and light, with five grading buttons and another button for cancellation.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-11
... cases for portable electronic devices. The complaint names as respondents Global Digital Star Industry... the United States, competitive conditions in the United States economy, the production of like or...
Stock, Konrad Friedrich; Klein, Bettina; Steubl, Dominik; Lersch, Christian; Heemann, Uwe; Wagenpfeil, Stefan; Eyer, Florian; Clevert, Dir-Andre
2015-10-01
Time savings and clinical accuracy of a new miniature ultrasound device was investigated utilizing comparison with conventional high-end ultrasound instruments. Our objective was to determine appropriate usage and limitations of this diagnostic tool in internal medicine. We investigated 28 patients from the internal-medicine department. Patients were examined with the Acuson P10 portable device and a Sonoline Antares instrument in a cross-over design. All investigations were carried out at the bedside; the results were entered on a standardized report form. The time for the ultrasound examination (transfer time, setting up and disassembly, switching on and off, and complete investigation time) was recorded separately. Mean time for overall examination per patient with the portable ultrasound device was shorter (25.0 ± 4.5 min) than with the high-end machine (29.4 ± 4.4 min; p < 0.001). When measuring the size of liver, spleen, and kidneys, the values obtained differed significantly between portable device and the high-end instrument. In our study, we identified 113 pathological ultrasound findings with the high-end ultrasound machine, while 82 pathological findings (73%) were concordantly detected with the portable ultrasound device. The main diagnostic strengths of the portable device were in the detection of ascites (sensitivity 80%), diagnosis of fatty liver, and identification of severe parenchymal liver damage. The clinical utility of portable ultrasound machines is limited. There will be clinical roles for distinct clinical questions such as detection of ascites or pleural effusion when used by experienced examiners. However, sensitivity in detecting multiple pathologies is not comparable to high-end ultrasound machines.
NASA Astrophysics Data System (ADS)
The present conference on global telecommunications discusses topics in the fields of Integrated Services Digital Network (ISDN) technology field trial planning and results to date, motion video coding, ISDN networking, future network communications security, flexible and intelligent voice/data networks, Asian and Pacific lightwave and radio systems, subscriber radio systems, the performance of distributed systems, signal processing theory, satellite communications modulation and coding, and terminals for the handicapped. Also discussed are knowledge-based technologies for communications systems, future satellite transmissions, high quality image services, novel digital signal processors, broadband network access interface, traffic engineering for ISDN design and planning, telecommunications software, coherent optical communications, multimedia terminal systems, advanced speed coding, portable and mobile radio communications, multi-Gbit/second lightwave transmission systems, enhanced capability digital terminals, communications network reliability, advanced antimultipath fading techniques, undersea lightwave transmission, image coding, modulation and synchronization, adaptive signal processing, integrated optical devices, VLSI technologies for ISDN, field performance of packet switching, CSMA protocols, optical transport system architectures for broadband ISDN, mobile satellite communications, indoor wireless communication, echo cancellation in communications, and distributed network algorithms.
Testing and assessment of portable seismic property analyzer.
DOT National Transportation Integrated Search
2014-02-01
Investigator will thoroughly test and assess the Portable Seismic Property Analyzer (PSPA), a hand-held device that focuses on : pavement layer properties. The device can be utilized on both rigid and flexible pavements. When used on rigid pavements,...
77 FR 4219 - FAA-Approved Portable Oxygen Concentrators; Technical Amendment
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-27
...-1343; Amdt. No. 121-358] FAA-Approved Portable Oxygen Concentrators; Technical Amendment AGENCY... amending regulations relating to operating rules for FAA approved portable oxygen concentrators (POC... Certain Portable Oxygen Concentrator Devices Onboard Aircraft'' (70 FR 40156). SFAR 106 permits passengers...
Using Personal Portable Devices as Learning Tools in the English Class
ERIC Educational Resources Information Center
Herrera Díaz, Luz Edith; Cruz Ramos, María de los Milagros; Sandoval Sánchez, Mario Alberto
2014-01-01
A group of university students used a variety of personal portable devices (cellphones, tablets, laptops, and netbooks) which distracted them in English class. This qualitative action research aimed to implement activities entailing the use of such devices and to learn their impact on students' learning and the use of English in class. Thus, a…
NASA Astrophysics Data System (ADS)
Kehagias, Dionysios D.; Giakoumis, Dimitris; Tzovaras, Dimitrios; Bekiaris, Evangelos; Wiethoff, Marion
This chapter presents an ambient intelligence framework whose goal is to facilitate the information needs of mobility impaired users on the move. This framework couples users with geographically distributed services and the corresponding multimedia content, enabling access to context-sensitive information based on user geographic location and the use case under consideration. It provides a multi-modal facility that is realized through a set of mobile devices and user interfaces that address the needs of ten different types of user impairments. The overall ambient intelligence framework enables users who are equipped with mobile devices to access multimedia content in order to undertake activities relevant to one or more of the following domains: transportation, tourism and leisure, personal support services, work, business, education, social relations and community building. User experience is being explored against those activities through a specific usage scenario.
A portable device for the measurement of evaporative water loss.
DOT National Transportation Integrated Search
1967-08-01
A portable device has been developed for the precise measurement of evaporative water loss. Under appropriate conditions the measurement of evaporative water loss may be used as an index of 'emotional stress' in flying personnel. The apparatus incorp...
Improving Quality Control of Asphalt Pavement with RAP Using a Portable Infrared Spectroscopy Device
DOT National Transportation Integrated Search
2016-04-01
This project has investigated the effectiveness of a Portable Infrared Spectrometer (PIRS) device in estimating percent of Reclaimed Asphalt Pavement (RAP) and its contribution into oxidative aging of a new asphalt mixture immediately after productio...
29 CFR 1917.119 - Portable ladders.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Requirements for Portable Reinforced Plastic Ladders (d) Standards for job-made portable ladders. Job-made... usage. (1) Ladders made by fastening rungs or devices across a single rail are prohibited. (2) Ladders...
Wireless Multimedia Sensor Networks: Current Trends and Future Directions
Almalkawi, Islam T.; Zapata, Manel Guerrero; Al-Karaki, Jamal N.; Morillo-Pozo, Julian
2010-01-01
Wireless Multimedia Sensor Networks (WMSNs) have emerged and shifted the focus from the typical scalar wireless sensor networks to networks with multimedia devices that are capable to retrieve video, audio, images, as well as scalar sensor data. WMSNs are able to deliver multimedia content due to the availability of inexpensive CMOS cameras and microphones coupled with the significant progress in distributed signal processing and multimedia source coding techniques. In this paper, we outline the design challenges of WMSNs, give a comprehensive discussion of the proposed architectures, algorithms and protocols for the different layers of the communication protocol stack for WMSNs, and evaluate the existing WMSN hardware and testbeds. The paper will give the reader a clear view of the state of the art at all aspects of this research area, and shed the light on its main current challenges and future trends. We also hope it will foster discussions and new research ideas among its researchers. PMID:22163571
Gibelli, Daniele; Pucciarelli, Valentina; Cappella, Annalisa; Dolci, Claudia; Sforza, Chiarella
2018-01-31
Modern 3-dimensional (3D) image acquisition systems represent a crucial technologic development in facial anatomy because of their accuracy and precision. The recently introduced portable devices can improve facial databases by increasing the number of applications. In the present study, the VECTRA H1 portable stereophotogrammetric device was validated to verify its applicability to 3D facial analysis. Fifty volunteers underwent 4 facial scans using portable VECTRA H1 and static VECTRA M3 devices (2 for each instrument). Repeatability of linear, angular, surface area, and volume measurements was verified within the device and between devices using the Bland-Altman test and the calculation of absolute and relative technical errors of measurement (TEM and rTEM, respectively). In addition, the 2 scans obtained by the same device and the 2 scans obtained by different devices were registered and superimposed to calculate the root mean square (RMS; point-to-point) distance between the 2 surfaces. Most linear, angular, and surface area measurements had high repeatability in M3 versus M3, H1 versus H1, and M3 versus H1 comparisons (range, 82.2 to 98.7%; TEM range, 0.3 to 2.0 mm, 0.4° to 1.8°; rTEM range, 0.2 to 3.1%). In contrast, volumes and RMS distances showed evident differences in M3 versus M3 and H1 versus H1 comparisons and reached the maximum when scans from the 2 different devices were compared. The portable VECTRA H1 device proved reliable for assessing linear measurements, angles, and surface areas; conversely, the influence of involuntary facial movements on volumes and RMS distances was more important compared with the static device. Copyright © 2018 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
van Duijnhoven, J; Aarts, M P J; Aries, M B C; Böhmer, M N; Rosemann, A L P
2017-01-01
The non-image-forming effects of luminous radiation on people with intellectual disabilities or dementia received attention from researchers. Such studies, however, have generally been conducted using disparate methodologies which precludes generalization and reproducibility. The aim of this study was to determine the practical applicability of measurement devices for studies investigating non-image-forming effects of luminous radiation, specifically for people with intellectual disabilities or dementia. In three experiments, ten cognitive impaired people and thirty-nine unaffected subjects participated by wearing one or more portable devices. Six devices were assessed in total. Measurement data was accompanied with user experiences obtained from questionnaires, interviews and observations in order to assess the devices on practical and comfort issues. On average, the devices worn by the cognitive impaired subjects were not experienced as annoying or irritating. No significant differences are found between genders and for one of the portable devices significantly less annoyance was reported by the cognitive impaired participants compared to the unaffected group of participants. The three phases of the research process in towards measuring personal luminous exposures are: selection of the most suitable portable device, application of the assessment method, and the application of the device in the (pilot) study. However, the findings of this study suggest that inaccuracies potentially caused by practical and comfort issues associated with the portable devices need to be considered.
An examination of safety reports involving electronic flight bags and portable electronic devices
DOT National Transportation Integrated Search
2014-06-01
The purpose of this research was to develop a better understanding of safety considerations with the use of Electronic Flight Bags (EFBs) and Portable Electronic Devices (PEDs) by examining safety reports from Aviation Safety Reporting System (ASRS),...
Effectively incorporating selected multimedia content into medical publications
2011-01-01
Until fairly recently, medical publications have been handicapped by being restricted to non-electronic formats, effectively preventing the dissemination of complex audiovisual and three-dimensional data. However, authors and readers could significantly profit from advances in electronic publishing that permit the inclusion of multimedia content directly into an article. For the first time, the de facto gold standard for scientific publishing, the portable document format (PDF), is used here as a platform to embed a video and an audio sequence of patient data into a publication. Fully interactive three-dimensional models of a face and a schematic representation of a human brain are also part of this publication. We discuss the potential of this approach and its impact on the communication of scientific medical data, particularly with regard to electronic and open access publications. Finally, we emphasise how medical teaching can benefit from this new tool and comment on the future of medical publishing. PMID:21329532
Effectively incorporating selected multimedia content into medical publications.
Ziegler, Alexander; Mietchen, Daniel; Faber, Cornelius; von Hausen, Wolfram; Schöbel, Christoph; Sellerer, Markus; Ziegler, Andreas
2011-02-17
Until fairly recently, medical publications have been handicapped by being restricted to non-electronic formats, effectively preventing the dissemination of complex audiovisual and three-dimensional data. However, authors and readers could significantly profit from advances in electronic publishing that permit the inclusion of multimedia content directly into an article. For the first time, the de facto gold standard for scientific publishing, the portable document format (PDF), is used here as a platform to embed a video and an audio sequence of patient data into a publication. Fully interactive three-dimensional models of a face and a schematic representation of a human brain are also part of this publication. We discuss the potential of this approach and its impact on the communication of scientific medical data, particularly with regard to electronic and open access publications. Finally, we emphasise how medical teaching can benefit from this new tool and comment on the future of medical publishing.
A review of the development of portable laser induced breakdown spectroscopy and its applications
NASA Astrophysics Data System (ADS)
Rakovský, J.; Čermák, P.; Musset, O.; Veis, P.
2014-11-01
In this review, we present person-transportable laser induced breakdown spectroscopy (LIBS) devices that have previously been developed and reported in the literature as well as their applications. They are compared with X-ray fluorescent (XRF) devices, which represent their strongest competition. Although LIBS devices have advantages over XRF devices, such as sensitivity to the light elements, high spatial resolution and the possibility to distinguish between different layers of the sample, there are also disadvantages and both are discussed here. Furthermore, the essential portable LIBS instrumentation (laser, spectrograph and detector) is presented, and published results related to new laser sources (diode-pumped solid-state, microchip and fiber lasers) used in LIBS are overviewed. Compared to conventional compact flashlamp pumped solid-state lasers, the new laser sources provide higher repetition rates, higher efficiency (less power consumption) and higher beam quality, resulting in higher fluences, even for lower energies, and could potentially increase the figure of merit of portable LIBS instruments. Compact spectrometers used in portable LIBS devices and their parts (spectrograph, detector) are also discussed.
Khan, Amber; Rao, Amitha; Reyes-Sacin, Carlos; Hayakawa, Kayoko; Szpunar, Susan; Riederer, Kathleen; Kaye, Keith; Fishbain, Joel T; Levine, Diane
2015-03-01
Portable electronic devices are increasingly being used in the hospital setting. As with other fomites, these devices represent a potential reservoir for the transmission of pathogens. We conducted a convenience sampling of devices in 2 large medical centers to identify bacterial colonization rates and potential risk factors. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Carbinatto, Fernanda M.; Inada, Natalia Mayumi; Lombardi, Welington; Cossetin, Natália Fernandez; Varoto, Cinthia; Kurachi, Cristina; Bagnato, Vanderlei Salvador
2015-06-01
The use of portable electronic devices, in particular mobile phones such as smartphones is increasing not only for all known applications, but also for diagnosis of diseases and monitoring treatments like topical Photodynamic Therapy. The aim of the study is to evaluate the production of the photosensitizer Protoporphyrin IX (PpIX) after topical application of a cream containing methyl aminolevulinate (MAL) in the cervix with diagnosis of Cervical Intraepithelial Neoplasia (CIN) through the fluorescence images captured after one and three hours and compare the images using two devices (a Sony Xperia® mobile and an Apple Ipod®. Was observed an increasing fluorescence intensity of the cervix three hours after cream application, in both portable electronic devices. However, because was used a specific program for the treatment of images using the Ipod® device, these images presented better resolution than observed by the Sony cell phone without a specific program. One hour after cream application presented a more selective fluorescence than the group of three hours. In conclusion, the use of portable devices to obtain images of PpIX fluorescence shown to be an effective tool and is necessary the improvement of programs for achievement of better results.
Patel, Nakul Gamanlal; Rozen, Warren Matthew; Marsh, Daniel; Chow, Whitney T H; Vickers, Tobias; Khan, Lubna; Miller, George S; Hunter-Smith, David J; Ramakrishnan, Venkat V
2016-04-01
Advances in mobile telecommunication, improved mobile internet and affordability have led to a significant increase in smartphone use within medicine. The capability of instant messaging, photography, videography, word processing, drawing and internet access allow significant potential in this small portable device. Smartphone use within medicine has grown tremendously worldwide given its affordability, improved internet and capabilities. We have searched for apps specifically helpful in the perioperative care of microsurgical breast reconstructive patients. The useful apps have been subdivided: (I) communication apps-multimedia messaging, WhatsApp, PicSafeMedi: allow efficient communication via text, picture and video messages leading to earlier assessment and definitive management of free flaps; (II) storage apps-Notability, Elogbook: electronic storage of patient notes and logbooks of case which can be shared with others if required; (III) educational apps-FlapApp, Touch Surgery, PubMed on tap: step by step guides to surgical procedures to aid learning and medical journal database; (IV) flap monitoring app-SilpaRamanitor: free flap monitoring app based on photographic analysis for earlier detection of compromised flaps. There has been remarkable growth in smartphones use among surgeons. Apps are being developed for every conceivable use. The future will be in wearable smart devices that allow continuous monitoring with the potential to instigate change should deviations from the norm occur. The smart watch is the start of this digital revolution.
Rozen, Warren Matthew; Marsh, Daniel; Chow, Whitney T.H.; Vickers, Tobias; Khan, Lubna; Miller, George S.; Hunter-Smith, David J.; Ramakrishnan, Venkat V.
2016-01-01
Background Advances in mobile telecommunication, improved mobile internet and affordability have led to a significant increase in smartphone use within medicine. The capability of instant messaging, photography, videography, word processing, drawing and internet access allow significant potential in this small portable device. Smartphone use within medicine has grown tremendously worldwide given its affordability, improved internet and capabilities. Methods We have searched for apps specifically helpful in the perioperative care of microsurgical breast reconstructive patients. Results The useful apps have been subdivided: (I) communication apps—multimedia messaging, WhatsApp, PicSafeMedi: allow efficient communication via text, picture and video messages leading to earlier assessment and definitive management of free flaps; (II) storage apps—Notability, Elogbook: electronic storage of patient notes and logbooks of case which can be shared with others if required; (III) educational apps—FlapApp, Touch Surgery, PubMed on tap: step by step guides to surgical procedures to aid learning and medical journal database; (IV) flap monitoring app—SilpaRamanitor: free flap monitoring app based on photographic analysis for earlier detection of compromised flaps. Conclusions There has been remarkable growth in smartphones use among surgeons. Apps are being developed for every conceivable use. The future will be in wearable smart devices that allow continuous monitoring with the potential to instigate change should deviations from the norm occur. The smart watch is the start of this digital revolution. PMID:27047783
NASA Technical Reports Server (NTRS)
Stoller, Ray A.; Wedding, Donald K.; Friedman, Peter S.
1993-01-01
A development status evaluation is presented for gas plasma display technology, noting how tradeoffs among the parameters of size, resolution, speed, portability, color, and image quality can yield cost-effective solutions for medical imaging, CAD, teleconferencing, multimedia, and both civil and military applications. Attention is given to plasma-based large-area displays' suitability for radar, sonar, and IR, due to their lack of EM susceptibility. Both monochrome and color displays are available.
Multimedia-based decision support system for hazards recognition and abatement
Czachowski, John B.; Zoldak, John T.
1998-01-01
A system for monitoring a site includes a portable data collection module used in the field to collect site specific data, and a processor module located at a central location. The data collection module displays choices of categories of findings, and then specific findings within each category. A selected specific finding is then displayed in report form with a citation to the specific code or statutory requirement, as well as a recommended course of action and an abatement date.
NAFFS: network attached flash file system for cloud storage on portable consumer electronics
NASA Astrophysics Data System (ADS)
Han, Lin; Huang, Hao; Xie, Changsheng
Cloud storage technology has become a research hotspot in recent years, while the existing cloud storage services are mainly designed for data storage needs with stable high speed Internet connection. Mobile Internet connections are often unstable and the speed is relatively low. These native features of mobile Internet limit the use of cloud storage in portable consumer electronics. The Network Attached Flash File System (NAFFS) presented the idea of taking the portable device built-in NAND flash memory as the front-end cache of virtualized cloud storage device. Modern portable devices with Internet connection have built-in more than 1GB NAND Flash, which is quite enough for daily data storage. The data transfer rate of NAND flash device is much higher than mobile Internet connections[1], and its non-volatile feature makes it very suitable as the cache device of Internet cloud storage on portable device, which often have unstable power supply and intermittent Internet connection. In the present work, NAFFS is evaluated with several benchmarks, and its performance is compared with traditional network attached file systems, such as NFS. Our evaluation results indicate that the NAFFS achieves an average accessing speed of 3.38MB/s, which is about 3 times faster than directly accessing cloud storage by mobile Internet connection, and offers a more stable interface than that of directly using cloud storage API. Unstable Internet connection and sudden power off condition are tolerable, and no data in cache will be lost in such situation.
Distributed processing for features improvement in real-time portable medical devices.
Mercado, Erwin John Saavedra
2008-01-01
Portable biomedical devices are being developed and incorporated in daily life. Nevertheless, their standalone capacity is diminished due to the lack of processing power required to face such duties as for example, signal artifacts robustness in EKG monitor devices. The following paper presents a multiprocessor architecture made from simple microcontrollers to provide an increase in processing performance, power consumption efficiency and lower cost.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-31
..., Including Mobile Phones and Components Thereof Notice of Receipt of Complaint; Solicitation of Comments... Certain Portable Electronic Communications Devices, Including Mobile Phones and Components Thereof, DN... mobile phones and components thereof. The complaint names as respondents HTC Corporation of China and HTC...
78 FR 6834 - Certain Cases for Portable Electronic Devices; Institution of Investigation
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-31
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-867] Certain Cases for Portable Electronic Devices; Institution of Investigation AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that a complaint was filed with the U.S. International Trade Commission on...
Tablet computer enhanced training improves internal medicine exam performance.
Baumgart, Daniel C; Wende, Ilja; Grittner, Ulrike
2017-01-01
Traditional teaching concepts in medical education do not take full advantage of current information technology. We aimed to objectively determine the impact of Tablet PC enhanced training on learning experience and MKSAP® (medical knowledge self-assessment program) exam performance. In this single center, prospective, controlled study final year medical students and medical residents doing an inpatient service rotation were alternatingly assigned to either the active test (Tablet PC with custom multimedia education software package) or traditional education (control) group, respectively. All completed an extensive questionnaire to collect their socio-demographic data, evaluate educational status, computer affinity and skills, problem solving, eLearning knowledge and self-rated medical knowledge. Both groups were MKSAP® tested at the beginning and the end of their rotation. The MKSAP® score at the final exam was the primary endpoint. Data of 55 (tablet n = 24, controls n = 31) male 36.4%, median age 28 years, 65.5% students, were evaluable. The mean MKSAP® score improved in the tablet PC (score Δ + 8 SD: 11), but not the control group (score Δ- 7, SD: 11), respectively. After adjustment for baseline score and confounders the Tablet PC group showed on average 11% better MKSAP® test results compared to the control group (p<0.001). The most commonly used resources for medical problem solving were journal articles looked up on PubMed or Google®, and books. Our study provides evidence, that tablet computer based integrated training and clinical practice enhances medical education and exam performance. Larger, multicenter trials are required to independently validate our data. Residency and fellowship directors are encouraged to consider adding portable computer devices, multimedia content and introduce blended learning to their respective training programs.
Tablet computer enhanced training improves internal medicine exam performance
Wende, Ilja; Grittner, Ulrike
2017-01-01
Background Traditional teaching concepts in medical education do not take full advantage of current information technology. We aimed to objectively determine the impact of Tablet PC enhanced training on learning experience and MKSAP® (medical knowledge self-assessment program) exam performance. Methods In this single center, prospective, controlled study final year medical students and medical residents doing an inpatient service rotation were alternatingly assigned to either the active test (Tablet PC with custom multimedia education software package) or traditional education (control) group, respectively. All completed an extensive questionnaire to collect their socio-demographic data, evaluate educational status, computer affinity and skills, problem solving, eLearning knowledge and self-rated medical knowledge. Both groups were MKSAP® tested at the beginning and the end of their rotation. The MKSAP® score at the final exam was the primary endpoint. Results Data of 55 (tablet n = 24, controls n = 31) male 36.4%, median age 28 years, 65.5% students, were evaluable. The mean MKSAP® score improved in the tablet PC (score Δ + 8 SD: 11), but not the control group (score Δ- 7, SD: 11), respectively. After adjustment for baseline score and confounders the Tablet PC group showed on average 11% better MKSAP® test results compared to the control group (p<0.001). The most commonly used resources for medical problem solving were journal articles looked up on PubMed or Google®, and books. Conclusions Our study provides evidence, that tablet computer based integrated training and clinical practice enhances medical education and exam performance. Larger, multicenter trials are required to independently validate our data. Residency and fellowship directors are encouraged to consider adding portable computer devices, multimedia content and introduce blended learning to their respective training programs. PMID:28369063
Adaptive Device Context Based Mobile Learning Systems
ERIC Educational Resources Information Center
Pu, Haitao; Lin, Jinjiao; Song, Yanwei; Liu, Fasheng
2011-01-01
Mobile learning is e-learning delivered through mobile computing devices, which represents the next stage of computer-aided, multi-media based learning. Therefore, mobile learning is transforming the way of traditional education. However, as most current e-learning systems and their contents are not suitable for mobile devices, an approach for…
Displays enabling mobile multimedia
NASA Astrophysics Data System (ADS)
Kimmel, Jyrki
2007-02-01
With the rapid advances in telecommunications networks, mobile multimedia delivery to handsets is now a reality. While a truly immersive multimedia experience is still far ahead in the mobile world, significant advances have been made in the constituent audio-visual technologies to make this become possible. One of the critical components in multimedia delivery is the mobile handset display. While such alternatives as headset-style near-to-eye displays, autostereoscopic displays, mini-projectors, and roll-out flexible displays can deliver either a larger virtual screen size than the pocketable dimensions of the mobile device can offer, or an added degree of immersion by adding the illusion of the third dimension in the viewing experience, there are still challenges in the full deployment of such displays in real-life mobile communication terminals. Meanwhile, direct-view display technologies have developed steadily, and can provide a development platform for an even better viewing experience for multimedia in the near future. The paper presents an overview of the mobile display technology space with an emphasis on the advances and potential in developing direct-view displays further to meet the goal of enabling multimedia in the mobile domain.
Handheld portable real-time tracking and communications device
Wiseman, James M [Albuquerque, NM; Riblett, Jr., Loren E.; Green, Karl L [Albuquerque, NM; Hunter, John A [Albuquerque, NM; Cook, III, Robert N.; Stevens, James R [Arlington, VA
2012-05-22
Portable handheld real-time tracking and communications devices include; a controller module, communications module including global positioning and mesh network radio module, data transfer and storage module, and a user interface module enclosed in a water-resistant enclosure. Real-time tracking and communications devices can be used by protective force, security and first responder personnel to provide situational awareness allowing for enhance coordination and effectiveness in rapid response situations. Such devices communicate to other authorized devices via mobile ad-hoc wireless networks, and do not require fixed infrastructure for their operation.
Portable data collection device
French, P.D.
1996-06-11
The present invention provides a portable data collection device that has a variety of sensors that are interchangeable with a variety of input ports in the device. The various sensors include a data identification feature that provides information to the device regarding the type of physical data produced by each sensor and therefore the type of sensor itself. The data identification feature enables the device to locate the input port where the sensor is connected and self adjust when a sensor is removed or replaced. The device is able to collect physical data, whether or not a function of a time. 7 figs.
Portable data collection device
French, Patrick D.
1996-01-01
The present invention provides a portable data collection device that has a variety of sensors that are interchangeable with a variety of input ports in the device. The various sensors include a data identification feature that provides information to the device regarding the type of physical data produced by each sensor and therefore the type of sensor itself. The data identification feature enables the device to locate the input port where the sensor is connected and self adjust when a sensor is removed or replaced. The device is able to collect physical data, whether or not a function of a time.
Method and apparatus of a portable imaging-based measurement with self calibration
Chang, Tzyy-Shuh [Ann Arbor, MI; Huang, Hsun-Hau [Ann Arbor, MI
2012-07-31
A portable imaging-based measurement device is developed to perform 2D projection based measurements on an object that is difficult or dangerous to access. This device is equipped with self calibration capability and built-in operating procedures to ensure proper imaging based measurement.
DOT National Transportation Integrated Search
1989-05-01
This study was undertaken, on request, to evaluate the performance of the Puritan-Bennett portable crew protective breathing device for contaminant leaks. O2, CO2 levels, inhalation/exhalation pressure, and inhalation temperature. Tests were conducte...
This is an ESTE project summary brief. EPA’s Environmental Technology Verification Program (ETV) is verifying the performance of portable optical and thermal imaging devices for leak detection at petroleum refineries and chemical plans. Industrial facilities, such as chemical p...
NASA Astrophysics Data System (ADS)
Poston, Terry L.
1989-10-01
The invention relates generally to the art of self-contained heating devices and in particular to portable heating devices employing chemical reaction to produce heat. Currently, hand-held heat sources, capable of producing heat at a sufficiently high temperature to activate heat-shrink material, rely on either the combustion of flammable material or electrical power to provide energy for generating the required heat. An object of the present invention is to provide a portable device capable of providing sufficient heat to shrink heat-shrinkable tubing. A further object of the invention is to provide a non-flammable heat source suitable for use in the presence of explosive atmospheres. Still another object of the invention is to provide a portable hand-held device for generating heat which can be directed to a specific location on a work surface.
Constantinescu, Liviu; Kim, Jinman; Feng, David Dagan
2012-01-01
With the advent of 4G and other long-term evolution (LTE) wireless networks, the traditional boundaries of patient record propagation are diminishing as networking technologies extend the reach of hospital infrastructure and provide on-demand mobile access to medical multimedia data. However, due to legacy and proprietary software, storage and decommissioning costs, and the price of centralization and redevelopment, it remains complex, expensive, and often unfeasible for hospitals to deploy their infrastructure for online and mobile use. This paper proposes the SparkMed data integration framework for mobile healthcare (m-Health), which significantly benefits from the enhanced network capabilities of LTE wireless technologies, by enabling a wide range of heterogeneous medical software and database systems (such as the picture archiving and communication systems, hospital information system, and reporting systems) to be dynamically integrated into a cloud-like peer-to-peer multimedia data store. Our framework allows medical data applications to share data with mobile hosts over a wireless network (such as WiFi and 3G), by binding to existing software systems and deploying them as m-Health applications. SparkMed integrates techniques from multimedia streaming, rich Internet applications (RIA), and remote procedure call (RPC) frameworks to construct a Self-managing, Pervasive Automated netwoRK for Medical Enterprise Data (SparkMed). Further, it is resilient to failure, and able to use mobile and handheld devices to maintain its network, even in the absence of dedicated server devices. We have developed a prototype of the SparkMed framework for evaluation on a radiological workflow simulation, which uses SparkMed to deploy a radiological image viewer as an m-Health application for telemedical use by radiologists and stakeholders. We have evaluated our prototype using ten devices over WiFi and 3G, verifying that our framework meets its two main objectives: 1) interactive delivery of medical multimedia data to mobile devices; and 2) attaching to non-networked medical software processes without significantly impacting their performance. Consistent response times of under 500 ms and graphical frame rates of over 5 frames per second were observed under intended usage conditions. Further, overhead measurements displayed linear scalability and low resource requirements.
Wallace, Sean; Clark, Marcia; White, Jonathan
2012-01-01
Objective The last decade has seen the introduction of new technology which has transformed many aspects of our culture, commerce, communication and education. This study examined how medical teachers and learners are using mobile computing devices such as the iPhone in medical education and practice, and how they envision them being used in the future. Design Semistructured interviews were conducted with medical students, residents and faculty to examine participants’ attitudes about the current and future use of mobile computing devices in medical education and practice. A thematic approach was used to summarise ideas and concepts expressed, and to develop an online survey. A mixed methods approach was used to integrate qualitative and quantitative findings. Setting and participants Medical students, residents and faculty at a large Canadian medical school in 2011. Results Interviews were conducted with 18 participants (10 students, 7 residents and 1 faculty member). Only 213 participants responded to the online survey (76 students, 65 residents and 41 faculty members). Over 85% of participants reported using a mobile-computing device. The main uses described for mobile devices related to information management, communication and time management. Advantages identified were portability, flexibility, access to multimedia and the ability to look up information quickly. Challenges identified included: superficial learning, not understanding how to find good learning resources, distraction, inappropriate use and concerns about access and privacy. Both medical students and physicians expressed the view that the use of these devices in medical education and practice will increase in the future. Conclusions This new technology offers the potential to enhance learning and patient care, but also has potential problems associated with its use. It is important for leadership in medical schools and healthcare organisations to set the agenda in this rapidly developing area to maximise the benefits of this powerful new technology while avoiding unintended consequences. PMID:22923627
Wallace, Sean; Clark, Marcia; White, Jonathan
2012-01-01
The last decade has seen the introduction of new technology which has transformed many aspects of our culture, commerce, communication and education. This study examined how medical teachers and learners are using mobile computing devices such as the iPhone in medical education and practice, and how they envision them being used in the future. Semistructured interviews were conducted with medical students, residents and faculty to examine participants' attitudes about the current and future use of mobile computing devices in medical education and practice. A thematic approach was used to summarise ideas and concepts expressed, and to develop an online survey. A mixed methods approach was used to integrate qualitative and quantitative findings. Medical students, residents and faculty at a large Canadian medical school in 2011. Interviews were conducted with 18 participants (10 students, 7 residents and 1 faculty member). Only 213 participants responded to the online survey (76 students, 65 residents and 41 faculty members). Over 85% of participants reported using a mobile-computing device. The main uses described for mobile devices related to information management, communication and time management. Advantages identified were portability, flexibility, access to multimedia and the ability to look up information quickly. Challenges identified included: superficial learning, not understanding how to find good learning resources, distraction, inappropriate use and concerns about access and privacy. Both medical students and physicians expressed the view that the use of these devices in medical education and practice will increase in the future. This new technology offers the potential to enhance learning and patient care, but also has potential problems associated with its use. It is important for leadership in medical schools and healthcare organisations to set the agenda in this rapidly developing area to maximise the benefits of this powerful new technology while avoiding unintended consequences.
Portable power supply options for positive airway pressure devices.
Riaz, Muhammad; Certal, Victor; Camacho, Macario
2015-01-01
Patients with obstructive sleep apnea (OSA) often face the challenge of how to power their positive airway pressure (PAP) devices when alternating current power supplies are not available in remote areas with lack of electricity or frequent power outages. This article elucidates portable power supply options for PAP devices with the aim to increase alternative power source awareness among medical providers. A search of scientific databases (Medline, Scopus, Web of Science, Google Scholar, and the Cochrane Library) was carried out on the topic of alternative portable power supply options for treatment of OSA. Scientific databases listed above yielded only limited results. Most articles were found via Google search. These articles were reviewed for alternative power supply options for OSA patients when alternating current is not available. The power supply options in this article include lead-acid batteries (starter, marine and deep-cycle batteries), lithium ion batteries, solar kits, battery packs, backup power systems, portable generators, and travel-size PAP devices. There are several options to power PAP devices with direct current when alternating current is not available. Knowledgeable primary care physicians especially in rural and remote areas can help OSA patients improve PAP compliance in order to mitigate morbidity and long-term complications of OSA.
Huang, Chih-Chung; Lee, Po-Yang; Chen, Pay-Yu; Liu, Ting-Yu
2012-01-01
Blood flow measurement using Doppler ultrasound has become a useful tool for diagnosing cardiovascular diseases and as a physiological monitor. Recently, pocket-sized ultrasound scanners have been introduced for portable diagnosis. The present paper reports the implementation of a portable ultrasound pulsed-wave (PW) Doppler flowmeter using a smartphone. A 10-MHz ultrasonic surface transducer was designed for the dynamic monitoring of blood flow velocity. The directional baseband Doppler shift signals were obtained using a portable analog circuit system. After hardware processing, the Doppler signals were fed directly to a smartphone for Doppler spectrogram analysis and display in real time. To the best of our knowledge, this is the first report of the use of this system for medical ultrasound Doppler signal processing. A Couette flow phantom, consisting of two parallel disks with a 2-mm gap, was used to evaluate and calibrate the device. Doppler spectrograms of porcine blood flow were measured using this stand-alone portable device under the pulsatile condition. Subsequently, in vivo portable system verification was performed by measuring the arterial blood flow of a rat and comparing the results with the measurement from a commercial ultrasound duplex scanner. All of the results demonstrated the potential for using a smartphone as a novel embedded system for portable medical ultrasound applications. © 2012 IEEE
Portable devices and mobile instruments for infectious diseases point-of-care testing.
Bissonnette, Luc; Bergeron, Michel G
2017-05-01
Rapidity, simplicity, and portability are highly desirable characteristics of tests and devices designed for performing diagnostics at the point of care (POC), either near patients managed in healthcare facilities or to offer bioanalytical alternatives in external settings. By reducing the turnaround time of the diagnostic cycle, POC diagnostics can reduce the dissemination, morbidity, and mortality of infectious diseases and provide tools to control the global threat of antimicrobial resistance. Areas covered: A literature search of PubMed and Google Scholar, and extensive mining of specialized publications, Internet resources, and manufacturers' websites have been used to organize and write this overview of the challenges and requirements associated with the development of portable sample-to-answer diagnostics, and showcase relevant examples of handheld devices, portable instruments, and less mobile systems which may or could be operated at POC. Expert commentary: Rapid (<1 h) diagnostics can contribute to control infectious diseases and antimicrobial resistant pathogens. Portable devices or instruments enabling sample-to-answer bioanalysis can provide rapid, robust, and reproducible testing at the POC or close from it. Beyond testing, to realize some promises of personalized/precision medicine, it will be critical to connect instruments to healthcare data management systems, to efficiently link decentralized testing results to the electronic medical record of patients.
Portable FAIMS: Applications and Future Perspectives.
Costanzo, Michael T; Boock, Jared J; Kemperman, Robin H J; Wei, Michael S; Beekman, Christopher R; Yost, Richard A
2017-11-01
Miniaturized mass spectrometry (MMS) is optimal for a wide variety of applications that benefit from field-portable instrumentation. Like MMS, field asymmetric ion mobility spectrometry (FAIMS) has proven capable of providing in situ analysis, allowing researchers to bring the lab to the sample. FAIMS compliments MMS very well, but has the added benefit of operating at atmospheric pressure, unlike MS. This distinct advantage makes FAIMS uniquely suited for portability. Since its inception, FAIMS has been envisioned as a field-portable device, as it affords less expense and greater simplicity than many similar methods. Ideally, these are simple, robust devices that may be operated by non-professional personnel, yet still provide adequate data when in the field. While reducing the size and complexity tends to bring with it a loss of performance and accuracy, this is made up for by the incredibly high throughput and overall convenience of the instrument. Moreover, the FAIMS device used in the field can be brought back to the lab, and coupled to a conventional mass spectrometer to provide any necessary method development and compound validation. This work discusses the various considerations, uses, and applications for portable FAIMS instrumentation, and how the future of each applicable field may benefit from the development and acceptance of such a device.
Portable Chemical Sterilizer (PCS) for Surgical Instruments
2004-12-01
PORTABLE CHEMICAL STERILIZER (PCS) FOR SURGICAL INSTRUMENTS CJ Doona*, FE Feeherry, MA Curtin‡, K Kustin‡, S Kandlikar‡ U.S. Army-Soldier...denotes Contractors) Biomedical Technologies ABSTRACT A novel device called the Portable Chemical Sterilizer (PCS) has been developed for the...rapid, safe, portable, power-free, and convenient sterilization of objects or surfaces contaminated with pathogenic microorganisms that cause
Portable bladder ultrasound: an evidence-based analysis.
2006-01-01
The aim of this review was to assess the clinical utility of portable bladder ultrasound. TARGET POPULATION AND CONDITION Data from the National Population Health Survey indicate prevalence rates of urinary incontinence are 2.5% in women and 1.4 % in men in the general population. Prevalence of urinary incontinence is higher in women than men and prevalence increases with age. Identified risk factors for urinary incontinence include female gender, increasing age, urinary tract infections (UTI), poor mobility, dementia, smoking, obesity, consuming alcohol and caffeine beverages, physical activity, pregnancy, childbirth, forceps and vacuum-assisted births, episiotomy, abdominal resection for colorectal cancer, and hormone replacement therapy. For the purposes of this review, incontinence populations will be stratified into the following; the elderly, urology patients, postoperative patients, rehabilitation settings, and neurogenic bladder populations. Urinary incontinence is defined as any involuntary leakage of urine. Incontinence can be classified into diagnostic clinical types that are useful in planning evaluation and treatment. The major types of incontinence are stress (physical exertion), urge (overactive bladder), mixed (combined urge and stress urinary incontinence), reflex (neurological impairment of the central nervous system), overflow (leakage due to full bladder), continuous (urinary tract abnormalities), congenital incontinence, and transient incontinence (temporary incontinence). Postvoid residual (PVR) urine volume, which is the amount of urine in the bladder immediately after urination, represents an important component in continence assessment and bladder management to provide quantitative feedback to the patient and continence care team regarding the effectiveness of the voiding technique. Although there is no standardized definition of normal PVR urine volume, measurements greater than 100 mL to 150 mL are considered an indication for urinary retention, requiring intermittent catheterization, whereas a PVR urine volume of 100 mL to 150 mL or less is generally considered an acceptable result of bladder training. Urinary retention has been associated with poor outcomes including UTI, bladder overdistension, and higher hospital mortality rates. The standard method of determining PVR urine volumes is intermittent catheterization, which is associated with increased risk of UTI, urethral trauma and discomfort. Portable bladder ultrasound products are transportable ultrasound devices that use automated technology to register bladder volume digitally, including PVR volume, and provide three-dimensional images of the bladder. The main clinical use of portable bladder ultrasound is as a diagnostic aid. Health care professionals (primarily nurses) administer the device to measure PVR volume and prevent unnecessary catheterization. An adjunctive use of the bladder ultrasound device is to visualize the placement and removal of catheters. Also, portable bladder ultrasound products may improve the diagnosis and differentiation of urological problems and their management and treatment, including the establishment of voiding schedules, study of bladder biofeedback, fewer UTIs, and monitoring of potential urinary incontinence after surgery or trauma. To determine the effectiveness and clinical utility of portable bladder ultrasound as reported in the published literature, the Medical Advisory Secretariat used its standard search strategy to retrieve international health technology assessments and English-language journal articles from selected databases. Nonsystematic reviews, nonhuman studies, case reports, letters, editorials, and comments were excluded. Of the 4 included studies that examined the clinical utility of portable bladder ultrasound in the elderly population, all found the device to be acceptable. One study reported that the device underestimated catheterized bladder volume In patients with urology problems, 2 of the 3 studies concerning portable bladder ultrasound found the device acceptable to use. However, one study did not find the device as accurate for small PVR volume as for catheterization and another found that the device overestimated catheterized bladder volume. In the remaining study, the authors reported that when the device's hand-held ultrasound transducers (scanheads) were aimed improperly, bladders were missed, or lateral borders of bladders were missed resulting in partial bladder volume measurements and underestimation of PVR measurements. They concluded that caution should be used in interpreting PVR volume measured by portable bladder ultrasound machines and that catheterization may be the preferred assessment modality if an accurate PVR measurement is necessary. All 3 studies with post-operative populations found portable bladder ultrasound use to be reasonably acceptable. Two studies reported that the device overestimated catheter-derived bladder volumes, one by 7% and the other by 21 mL. The third study reported the opposite, that the device underestimated catheter bladder volume by 39 mL but that the results remained acceptable In rehabilitation settings, 2 studies found portable bladder ultrasound to underestimate catheter-derived bladder volumes; yet, both authors concluded that the mean errors were within acceptable limits. In patients with neurogenic bladder problems, 2 studies found portable bladder ultrasound to be an acceptable alternative to catheterization despite the fact that it was not as accurate as catheterization for obtaining bladder volumes. Lastly, examinations concerning avoidance of negative health outcomes showed that, after use of the portable bladder ultrasound, unnecessary catheterizations and UTIs were decreased. Unnecessary catheterizations avoided ranged from 16% to 47% in the selected articles. Reductions in UTI ranged from 38% to 72%. In sum, all but one study advocated the use of portable bladder ultrasound as an alternative to catheterization. An economic analysis estimating the budget-impact of BladderScan in complex continuing care facilities was completed. The analysis results indicated a $192,499 (Cdn) cost-savings per year per facility and a cost-savings of $2,887,485 (Cdn) for all 15 CCC facilities. No economic analysis was completed for long-term care and acute care facilities due to lack of data. Rapid diffusion of portable bladder ultrasound technology is expected. Recently, the IC5 project on improving continence care in Ontario's complex continuing care centres piloted portable bladder ultrasound at 12 sites. Preliminary results were promising. Many physicians and health care facilities already have portable bladder ultrasound devices. However, portable bladder ultrasound devices for PVR measurement are not in use at most health care facilities in Ontario and Canada. The Verathon Corporation (Bothell, Wisconsin, United States), which patents BladderScan, is the sole licensed manufacturer of the portable bladder ultrasound in Canada. Field monopoly may influence the rising costs of portable bladder ultrasound, particularly when faced with rapid expansion of the technology. Several thousand residents of Ontario would benefit from portable bladder ultrasound. The number of residents of Ontario that would benefit from the technology is difficult to quantify, because the incidence and prevalence of incontinence are grossly under-reported. However, long-term care and complex continuing care institutions would benefit greatly from portable bladder ultrasound, as would numerous rehabilitation units, postsurgical care units, and urology clinics. The cost of the portable bladder ultrasound devices ranges from $17,698.90 to $19,565.95 (Cdn) (total purchase price per unit as quoted by the manufacturer). Additional training packages, batteries and battery chargers, software, gel pads, and yearly warranties are additional costs. Studies indicate that portable bladder ultrasound is a cost-effective technology, because it avoids costs associated with catheterization equipment, saves nursing time, and reduces catheter-related complications and UTIs. The use of portable bladder ultrasound device will affect the patient directly in terms of health outcomes. Its use avoids the trauma related to the urinary tract that catheterization inflicts, and does not result in UTIs. In addition, patients prefer it, because it preserves dignity and reduces discomfort.
Portable Integrated Wireless Device Threat Assessment to Aircraft Radio Systems
NASA Technical Reports Server (NTRS)
Salud, Maria Theresa P.; Williams, Reuben A. (Technical Monitor)
2004-01-01
An assessment was conducted on multiple wireless local area network (WLAN) devices using the three wireless standards for spurious radiated emissions to determine their threat to aircraft radio navigation systems. The measurement process, data and analysis are provided for devices tested using IEEE 802.11a, IEEE 802.11b, and Bluetooth as well as data from portable laptops/tablet PCs and PDAs (grouping known as PEDs). A comparison was made between wireless LAN devices and portable electronic devices. Spurious radiated emissions were investigated in the radio frequency bands for the following aircraft systems: Instrument Landing System Localizer and Glideslope, Very High Frequency (VHF) Communication, VHF Omnidirectional Range, Traffic Collision Avoidance System, Air Traffic Control Radar Beacon System, Microwave Landing System and Global Positioning System. Since several of the contiguous navigation systems were grouped under one encompassing measurement frequency band, there were five measurement frequency bands where spurious radiated emissions data were collected for the PEDs and WLAN devices. The report also provides a comparison between emissions data and regulatory emission limit.
Software for keratometry measurements using portable devices
NASA Astrophysics Data System (ADS)
Iyomasa, C. M.; Ventura, L.; De Groote, J. J.
2010-02-01
In this work we present an image processing software for automatic astigmatism measurements developed for a hand held keratometer. The system projects 36 light spots, from LEDs, displayed in a precise circle at the lachrymal film of the examined cornea. The displacement, the size and deformation of the reflected image of these light spots are analyzed providing the keratometry. The purpose of this research is to develop a software that performs fast and precise calculations in mainstream mobile devices. In another words, a software that can be implemented in portable computer systems, which could be of low cost and easy to handle. This project allows portability for keratometers and is a previous work for a portable corneal topographer.
Laser Spiderweb Sensor Used with Portable Handheld Devices
NASA Technical Reports Server (NTRS)
Scott, David C. (Inventor); Ksendzov, Alexander (Inventor); George, Warren P. (Inventor); Smith, James A. (Inventor); Steinkraus, Joel M. (Inventor); Hofmann, Douglas C. (Inventor); Aljabri, Abdullah S. (Inventor); Bendig, Rudi M. (Inventor)
2017-01-01
A portable spectrometer, including a smart phone case storing a portable spectrometer, wherein the portable spectrometer includes a cavity; a source for emitting electromagnetic radiation that is directed on a sample in the cavity, wherein the electromagnetic radiation is reflected within the cavity to form multiple passes of the electromagnetic radiation through the sample; a detector for detecting the electromagnetic radiation after the electromagnetic radiation has made the multiple passes through the sample in the cavity, the detector outputting a signal in response to the detecting; and a device for communicating the signal to a smart phone, wherein the smart phone executes an application that performs a spectral analysis of the signal.
Cooley, Philip C.; Turner, Charles F.; O'Reilly, James M.; Allen, Danny R.; Hamill, David N.; Paddock, Richard E.
2011-01-01
This article reviews a multimedia application in the area of survey measurement research: adding audio capabilities to a computer-assisted interviewing system. Hardware and software issues are discussed, and potential hardware devices that operate from DOS platforms are reviewed. Three types of hardware devices are considered: PCMCIA devices, parallel port attachments, and laptops with built-in sound. PMID:22096271
Learning with Portable Digital Devices in Australian Schools: 20 Years On!
ERIC Educational Resources Information Center
Newhouse, C. Paul
2014-01-01
Portable computing technologies such as laptops, tablets, smartphones, wireless networking, voice/stylus input, and plug and play peripheral devices, appear to offer the means of finally realising much of the long heralded vision for computers to support learning in schools. There is the possibility for the technology to finally become a…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-12
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-701] In the Matter of Certain Electronic Devices, Including Mobile Phones, Portable Music Players, and Computers; Notice of Commission... music players, and computers by reason of infringement of various claims of United States Patent Nos. 6...
Portable Technology Comes of Age
ERIC Educational Resources Information Center
Wangemann, Paul; Lewis, Nina; Squires, David A.
2003-01-01
The PDA was originally conceived of as a portable handheld electronic device that provided a user with a tool to organize his or her life through easy access to a personal calendar, daily planner, and address book. Over the years, these devices have expanded to include many new functions, which have helped more applications in diverse fields. This…
The Future of Portable Devices is the "PITs"
ERIC Educational Resources Information Center
Peters, Tom; Bell, Lori
2006-01-01
According to recent media reports, MP3 players are one of the hottest gift item these days, particularly for adolescents. The broad success of these devices, however, has revealed flaws in the designers' noninclusive thinking. The accessibility challenges for these players are similar to those for other portable electronic gadgets, such as PDAs…
Portable recording in the assessment of obstructive sleep apnea. ASDA standards of practice.
Ferber, R; Millman, R; Coppola, M; Fleetham, J; Murray, C F; Iber, C; McCall, V; Nino-Murcia, G; Pressman, M; Sanders, M
1994-06-01
The objective assessment of patients with a presumptive diagnosis of obstructive sleep apnea (OSA) has primarily used attended polysomnographic study. Recent technologic advances and issues of availability, convenience and cost have led to a rapid increase in the use of portable recording devices. However, limited scientific information has been published regarding the evaluation of the efficacy, accuracy, validity, utility, cost effectiveness and limitations of this portable equipment. Attaining a clear assessment of the role of portable devices is complicated by the multiplicity of recording systems and the variability of clinical settings in which they have been analyzed. This paper reviews the current knowledge base regarding portable recording in the assessment of OSA, including technical considerations, validation studies, potential advantages and disadvantages, issues of safety, current clinical usage and areas most in need of further study.
ERIC Educational Resources Information Center
Downs, Edward; Boyson, Aaron R.; Alley, Hannah; Bloom, Nikki R.
2011-01-01
Some institutions of higher learning have invested considerable resources to diffuse iPods and MP3 devices though little is known about learning outcomes tied to their use. Dual-coding and multimedia learning theories guided the development of a typical college lecture so that it could be presented in a combination of audio and visual forms across…
Portable oxygen subsystem. [design analysis and performance tests
NASA Technical Reports Server (NTRS)
1975-01-01
The concept and design of a portable oxygen device for use in the space shuttle orbiter is presented. Hardware fabrication and acceptance tests (i.e., breadboard models) are outlined and discussed. Optimization of the system (for weight, volume, safety, costs) is discussed. The device is of the rebreather type, and provides a revitalized breathing gas supply to a crewman for denitrogenization and emergency activities. Engineering drawings and photographs of the device are shown.
Jang, Hyunwook; Ahmed, Syed Rahin; Neethirajan, Suresh
2017-01-01
Enzyme-linked immunosorbent assay (ELISA) is a popular assay technique for the detection and quantification of various biological substances due its high sensitivity and specificity. More often, it requires large and expensive laboratory instruments, which makes it difficult to conduct when the tests must be performed quickly at the point-of-care (POC). To increase portability and ease of use, we propose a portable diagnostic system based on a Raspberry Pi imaging sensor for the rapid detection of progesterone in milk samples. We designed, assembled, and tested a standalone portable diagnostic reader and validated it for progesterone detection against a standard ELISA assay using a commercial plate reader. The portable POC device yielded consistent results, regardless of differences in the cameras and flashlights between various smartphone devices. An Android application was built to provide front-end access to users, control the diagnostic reader, and display and store the progesterone measurement on the smartphone. The diagnostic reader takes images of the samples, reads the pixel values, processes the results, and presents the results on the handheld device. The proposed POC reader can perform to superior levels of performance as a plate reader, while adding the desirable qualities of portability and ease of use. PMID:28489036
Jang, Hyunwook; Ahmed, Syed Rahin; Neethirajan, Suresh
2017-05-10
Enzyme-linked immunosorbent assay (ELISA) is a popular assay technique for the detection and quantification of various biological substances due its high sensitivity and specificity. More often, it requires large and expensive laboratory instruments, which makes it difficult to conduct when the tests must be performed quickly at the point-of-care (POC). To increase portability and ease of use, we propose a portable diagnostic system based on a Raspberry Pi imaging sensor for the rapid detection of progesterone in milk samples. We designed, assembled, and tested a standalone portable diagnostic reader and validated it for progesterone detection against a standard ELISA assay using a commercial plate reader. The portable POC device yielded consistent results, regardless of differences in the cameras and flashlights between various smartphone devices. An Android application was built to provide front-end access to users, control the diagnostic reader, and display and store the progesterone measurement on the smartphone. The diagnostic reader takes images of the samples, reads the pixel values, processes the results, and presents the results on the handheld device. The proposed POC reader can perform to superior levels of performance as a plate reader, while adding the desirable qualities of portability and ease of use.
Portable data collection device with self identifying probe
French, P.D.
1998-11-17
The present invention provides a portable data collection device that has a variety of sensors that are interchangeable with a variety of input ports in the device. The various sensors include a data identification feature that provides information to the device regarding the type of physical data produced by each sensor and therefore the type of sensor itself. The data identification feature enables the device to locate the input port where the sensor is connected and self adjust when a sensor is removed or replaced. The device is able to collect physical data, whether or not a function of time. The sensor may also store a unique sensor identifier. 13 figs.
Portable data collection device with self identifying probe
French, Patrick D.
1998-01-01
The present invention provides a portable data collection device that has a variety of sensors that are interchangeable with a variety of input ports in the device. The various sensors include a data identification feature that provides information to the device regarding the type of physical data produced by each sensor and therefore the type of sensor itself. The data identification feature enables the device to locate the input port where the sensor is connected and self adjust when a sensor is removed or replaced. The device is able to collect physical data, whether or not a function of time. The sensor may also store a unique sensor identifier.
2006-01-01
Executive Summary Objective The aim of this review was to assess the clinical utility of portable bladder ultrasound. Clinical Need: Target Population and Condition Data from the National Population Health Survey indicate prevalence rates of urinary incontinence are 2.5% in women and 1.4 % in men in the general population. Prevalence of urinary incontinence is higher in women than men and prevalence increases with age. Identified risk factors for urinary incontinence include female gender, increasing age, urinary tract infections (UTI), poor mobility, dementia, smoking, obesity, consuming alcohol and caffeine beverages, physical activity, pregnancy, childbirth, forceps and vacuum-assisted births, episiotomy, abdominal resection for colorectal cancer, and hormone replacement therapy. For the purposes of this review, incontinence populations will be stratified into the following; the elderly, urology patients, postoperative patients, rehabilitation settings, and neurogenic bladder populations. Urinary incontinence is defined as any involuntary leakage of urine. Incontinence can be classified into diagnostic clinical types that are useful in planning evaluation and treatment. The major types of incontinence are stress (physical exertion), urge (overactive bladder), mixed (combined urge and stress urinary incontinence), reflex (neurological impairment of the central nervous system), overflow (leakage due to full bladder), continuous (urinary tract abnormalities), congenital incontinence, and transient incontinence (temporary incontinence). Postvoid residual (PVR) urine volume, which is the amount of urine in the bladder immediately after urination, represents an important component in continence assessment and bladder management to provide quantitative feedback to the patient and continence care team regarding the effectiveness of the voiding technique. Although there is no standardized definition of normal PVR urine volume, measurements greater than 100 mL to 150 mL are considered an indication for urinary retention, requiring intermittent catheterization, whereas a PVR urine volume of 100 mL to 150 mL or less is generally considered an acceptable result of bladder training. Urinary retention has been associated with poor outcomes including UTI, bladder overdistension, and higher hospital mortality rates. The standard method of determining PVR urine volumes is intermittent catheterization, which is associated with increased risk of UTI, urethral trauma and discomfort. The Technology Being Reviewed Portable bladder ultrasound products are transportable ultrasound devices that use automated technology to register bladder volume digitally, including PVR volume, and provide three-dimensional images of the bladder. The main clinical use of portable bladder ultrasound is as a diagnostic aid. Health care professionals (primarily nurses) administer the device to measure PVR volume and prevent unnecessary catheterization. An adjunctive use of the bladder ultrasound device is to visualize the placement and removal of catheters. Also, portable bladder ultrasound products may improve the diagnosis and differentiation of urological problems and their management and treatment, including the establishment of voiding schedules, study of bladder biofeedback, fewer UTIs, and monitoring of potential urinary incontinence after surgery or trauma. Review Strategy To determine the effectiveness and clinical utility of portable bladder ultrasound as reported in the published literature, the Medical Advisory Secretariat used its standard search strategy to retrieve international health technology assessments and English-language journal articles from selected databases. Nonsystematic reviews, nonhuman studies, case reports, letters, editorials, and comments were excluded. Summary of Findings Of the 4 included studies that examined the clinical utility of portable bladder ultrasound in the elderly population, all found the device to be acceptable. One study reported that the device underestimated catheterized bladder volume In patients with urology problems, 2 of the 3 studies concerning portable bladder ultrasound found the device acceptable to use. However, one study did not find the device as accurate for small PVR volume as for catheterization and another found that the device overestimated catheterized bladder volume. In the remaining study, the authors reported that when the device’s hand-held ultrasound transducers (scanheads) were aimed improperly, bladders were missed, or lateral borders of bladders were missed resulting in partial bladder volume measurements and underestimation of PVR measurements. They concluded that caution should be used in interpreting PVR volume measured by portable bladder ultrasound machines and that catheterization may be the preferred assessment modality if an accurate PVR measurement is necessary. All 3 studies with post-operative populations found portable bladder ultrasound use to be reasonably acceptable. Two studies reported that the device overestimated catheter-derived bladder volumes, one by 7% and the other by 21 mL. The third study reported the opposite, that the device underestimated catheter bladder volume by 39 mL but that the results remained acceptable In rehabilitation settings, 2 studies found portable bladder ultrasound to underestimate catheter-derived bladder volumes; yet, both authors concluded that the mean errors were within acceptable limits. In patients with neurogenic bladder problems, 2 studies found portable bladder ultrasound to be an acceptable alternative to catheterization despite the fact that it was not as accurate as catheterization for obtaining bladder volumes. Lastly, examinations concerning avoidance of negative health outcomes showed that, after use of the portable bladder ultrasound, unnecessary catheterizations and UTIs were decreased. Unnecessary catheterizations avoided ranged from 16% to 47% in the selected articles. Reductions in UTI ranged from 38% to 72%. In sum, all but one study advocated the use of portable bladder ultrasound as an alternative to catheterization. Economic Analysis An economic analysis estimating the budget-impact of BladderScan in complex continuing care facilities was completed. The analysis results indicated a $192,499 (Cdn) cost-savings per year per facility and a cost-savings of $2,887,485 (Cdn) for all 15 CCC facilities. No economic analysis was completed for long-term care and acute care facilities due to lack of data. Considerations for Policy Development Rapid diffusion of portable bladder ultrasound technology is expected. Recently, the IC5 project on improving continence care in Ontario’s complex continuing care centres piloted portable bladder ultrasound at 12 sites. Preliminary results were promising. Many physicians and health care facilities already have portable bladder ultrasound devices. However, portable bladder ultrasound devices for PVR measurement are not in use at most health care facilities in Ontario and Canada. The Verathon Corporation (Bothell, Wisconsin, United States), which patents BladderScan, is the sole licensed manufacturer of the portable bladder ultrasound in Canada. Field monopoly may influence the rising costs of portable bladder ultrasound, particularly when faced with rapid expansion of the technology. Several thousand residents of Ontario would benefit from portable bladder ultrasound. The number of residents of Ontario that would benefit from the technology is difficult to quantify, because the incidence and prevalence of incontinence are grossly under-reported. However, long-term care and complex continuing care institutions would benefit greatly from portable bladder ultrasound, as would numerous rehabilitation units, postsurgical care units, and urology clinics. The cost of the portable bladder ultrasound devices ranges from $17,698.90 to $19,565.95 (Cdn) (total purchase price per unit as quoted by the manufacturer). Additional training packages, batteries and battery chargers, software, gel pads, and yearly warranties are additional costs. Studies indicate that portable bladder ultrasound is a cost-effective technology, because it avoids costs associated with catheterization equipment, saves nursing time, and reduces catheter-related complications and UTIs. The use of portable bladder ultrasound device will affect the patient directly in terms of health outcomes. Its use avoids the trauma related to the urinary tract that catheterization inflicts, and does not result in UTIs. In addition, patients prefer it, because it preserves dignity and reduces discomfort. PMID:23074481
Computer-generated graphical presentations: use of multimedia to enhance communication.
Marks, L S; Penson, D F; Maller, J J; Nielsen, R T; deKernion, J B
1997-01-01
Personal computers may be used to create, store, and deliver graphical presentations. With computer-generated combinations of the five media (text, images, sound, video, and animation)--that is, multimedia presentations--the effectiveness of message delivery can be greatly increased. The basic tools are (1) a personal computer; (2) presentation software; and (3) a projector to enlarge the monitor images for audience viewing. Use of this new method has grown rapidly in the business-conference world, but has yet to gain widespread acceptance at medical meetings. We review herein the rationale for multimedia presentations in medicine (vis-à-vis traditional slide shows) as an improved means for increasing audience attention, comprehension, and retention. The evolution of multimedia is traced from earliest times to the present. The steps involved in making a multimedia presentation are summarized, emphasizing advances in technology that bring the new method within practical reach of busy physicians. Specific attention is given to software, digital image processing, storage devices, and delivery methods. Our development of a urology multimedia presentation--delivered May 4, 1996, before the Society for Urology and Engineering and now Internet-accessible at http://www.usrf.org--was the impetus for this work.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-24
...--Equities That Would Not Permit Floor Brokers to Use Personal Portable Phone Devices on the Trading Floor Due to the Unavailability of Exchange-Provided Cell Phones on September 11, 2013 September 18, 2013... Floor brokers to use personal portable phone devices on the Trading Floor due to the unavailability of...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-24
... That Would Not Permit Floor Brokers To Use Personal Portable Phone Devices on the Trading Floor Due to the Unavailability of Exchange-Provided Cell Phones on September 11, 2013 September 18, 2013. Pursuant... personal portable phone devices on the Trading Floor due to the unavailability of Exchange-provided cell...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-13
... Portable Phone Devices on the Trading Floor Following the Aftermath of Hurricane Sandy From November 5, 2012 Until the Earlier of When Phone Service Is Fully Restored or Friday, November 9, 2012 November 5... Designated Market Makers (``DMMs'') and Floor brokers to use personal portable phone devices on the Trading...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-27
... Not Permit Floor Brokers To Use Personal Portable Phone Devices on the Trading Floor Following the Aftermath of Hurricane Sandy Until the Earlier of When Phone Service Is Fully Restored or Friday, December...--Equities and 36.21--Equities that would not permit Floor brokers to use personal portable phone devices on...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-13
... That Would Not Permit Designated Market Makers and Floor Brokers To Use Personal Portable Phone Devices... Earlier of When Phone Service Is Fully Restored or Friday, November 9, 2012 November 5, 2012. Pursuant to... (``DMMs'') and Floor brokers to use personal portable phone devices on the Trading Floor following the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-12
... Related Software; Notice of Institution of Investigation; Institution of Investigation Pursuant to 19 U.S... software by reason of infringement of certain claims of U.S. Patent No. 7,844,915 (``the `915 patent''); U... after importation of certain portable electronic devices and related software that infringe one or more...
ERIC Educational Resources Information Center
Mechling, Linda C.
2011-01-01
Use of portable electronic devices by persons with moderate intellectual disabilities and autism spectrum disorders is gaining increased research attention. The purpose of this review was to synthesize twenty-first century literature (2000-2010) focusing on these technologies. Twenty-one studies were identified which evaluated use of: (a) handheld…
DOT National Transportation Integrated Search
2010-06-11
The purpose of this document is to present the findings of the national evaluation of the deployment of portable traffic monitoring devices (PTMDs) at a variety of locations in North Carolina conducted under the USDOTs SafeTrip-21 Initiative. The ...
DOT National Transportation Integrated Search
2010-06-11
The purpose of this document is to present the findings of the national evaluation of the deployment of portable trafficmonitoring devices (PTMDs) at a variety of locations in North Carolina conducted under the USDOTs SafeTrip-21 Initiative. The N...
A knee-mounted biomechanical energy harvester with enhanced efficiency and safety
NASA Astrophysics Data System (ADS)
Chen, Chao; Chau, Li Yin; Liao, Wei-Hsin
2017-06-01
Energy harvesting is becoming a major limiting issue for many portable devices. When undertaking any activity, the human body generates a significant amount of biomechanical energy, which can be collected by means of a portable energy harvester. This energy provides a method of powering portable devices such as prosthetic limbs. In this paper, a knee-mounted energy harvester with enhanced efficiency and safety is proposed and developed to convert mechanical energy into electricity during human motion. This device can change the bi-directional knee input into uni-directional rotation for an electromagnetic generator using a specially designed transmission system. Without the constraint of induced impact on the human body, this device can harvest biomechanical energy from both knee flexion and extension, improving the harvesting efficiency over previous single-direction energy harvesters. It can also provide protection from device malfunction, and increase the safety of current biomechanical energy harvesters. A highly compact and light prototype is developed taking into account human kinematics. The biomechanical energy harvesting system is also modeled and analyzed. The prototype is tested under different conditions including walking, running and climbing stairs, to evaluate the energy harvesting performance and effect on the human gait. The experimental results show that the prototype can harvest an average power of 3.6 W at 1.5 m s-1 walking speed, which is promising for portable electronic devices.
Nie, L H; Sanchez, S; Newton, K; Grodzins, L; Cleveland, R O; Weisskopf, M G
2011-02-07
This study was conducted to investigate the methodology and feasibility of developing a portable x-ray fluorescence (XRF) technology to quantify lead (Pb) in bone in vivo. A portable XRF device was set up and optimal settings of voltage, current, and filter combination for bone lead quantification were selected to achieve the lowest detection limit. The minimum radiation dose delivered to the subject was calculated by Monte Carlo simulations. An ultrasound device was used to measure soft tissue thickness to account for signal attenuation, and an alternative method to obtain soft tissue thickness from the XRF spectrum was developed and shown to be equivalent to the ultrasound measurements (intraclass correlation coefficient, ICC = 0.82). We tested the correlation of in vivo bone lead concentrations between the standard KXRF technology and the portable XRF technology. There was a significant correlation between the bone lead concentrations obtained from the standard KXRF technology and those obtained from the portable XRF technology (ICC = 0.65). The detection limit for the portable XRF device was about 8.4 ppm with 2 mm soft tissue thickness. The entrance skin dose delivered to the human subject was about 13 mSv and the total body effective dose was about 1.5 µSv and should pose minimal radiation risk. In conclusion, portable XRF technology can be used for in vivo bone lead measurement with sensitivity comparable to the KXRF technology and good correlation with KXRF measurements.
Nie, LH; Sanchez, S; Newton, K; Grodzins, L; Cleveland, RO; Weisskopf, MG
2013-01-01
This study was conducted to investigate the methodology and feasibility of developing a portable XRF technology to quantify lead (Pb) in bone in vivo. A portable XRF device was set up and optimal setting of voltage, current, and filter combination for bone lead quantification were selected to achieve the lowest detection limit. The minimum radiation dose delivered to the subject was calculated by Monte Carlo simulations. An ultrasound device was used to measure soft tissue thickness to account for signal attenuation, and an alternative method to obtain soft tissue thickness from the XRF spectrum was developed and shown to be equivalent to the ultrasound measurements (Intraclass Correlation Coefficient, ICC=0.82). We tested the correlation of in vivo bone lead concentrations between the standard KXRF technology and the portable XRF technology. There was a significant correlation between the bone lead concentrations obtained from the standard KXRF technology and those obtained from the portable XRF technology (ICC=0.65). The detection limit for the portable XRF device was about 8.4 ppm with 2 mm soft tissue thickness. The entrance skin dose delivered to the human subject was about 13 mSv and the total body effective dose was about 1.5 μSv and should pose a minimal radiation risk. In conclusion, portable XRF technology can be used for in vivo bone lead measurement with sensitivity comparable to the KXRF technology and good correlation with KXRF measurements. PMID:21242629
21 CFR 878.4680 - Nonpowered, single patient, portable suction apparatus.
Code of Federal Regulations, 2011 CFR
2011-04-01
... apparatus. 878.4680 Section 878.4680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....4680 Nonpowered, single patient, portable suction apparatus. (a) Identification. A nonpowered, single patient, portable suction apparatus is a device that consists of a manually operated plastic, disposable...
21 CFR 878.4680 - Nonpowered, single patient, portable suction apparatus.
Code of Federal Regulations, 2010 CFR
2010-04-01
... apparatus. 878.4680 Section 878.4680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....4680 Nonpowered, single patient, portable suction apparatus. (a) Identification. A nonpowered, single patient, portable suction apparatus is a device that consists of a manually operated plastic, disposable...
A programmable and portable NMES device for drop foot correction and blood flow assist applications.
Breen, Paul P; Corley, Gavin J; O'Keeffe, Derek T; Conway, Richard; Olaighin, Gearóid
2009-04-01
The Duo-STIM, a new, programmable and portable neuromuscular stimulation system for drop foot correction and blood flow assist applications is presented. The system consists of a programmer unit and a portable, programmable stimulator unit. The portable stimulator features fully programmable, sensor-controlled, constant-voltage, dual-channel stimulation and accommodates a range of customized stimulation profiles. Trapezoidal and free-form adaptive stimulation intensity envelope algorithms are provided for drop foot correction applications, while time dependent and activity dependent algorithms are provided for blood flow assist applications. A variety of sensor types can be used with the portable unit, including force sensitive resistor-based foot switches and MEMS-based accelerometer and gyroscope devices. The paper provides a detailed description of the hardware and block-level system design for both units. The programming and operating procedures for the system are also presented. Finally, functional bench test results for the system are presented.
A programmable and portable NMES device for drop foot correction and blood flow assist applications.
Breen, Paul P; Corley, Gavin J; O'Keeffe, Derek T; Conway, Richard; OLaighin, Gearoid
2007-01-01
The Duo-STIM, a new, programmable and portable neuromuscular stimulation system for drop foot correction and blood flow assist applications is presented. The system consists of a programmer unit and a portable, programmable stimulator unit. The portable stimulator features fully programmable, sensor-controlled, constant-voltage, dual-channel stimulation and accommodates a range of customized stimulation profiles. Trapezoidal and free-form adaptive stimulation intensity envelope algorithms are provided for drop foot correction applications, while time dependent and activity dependent algorithms are provided for blood flow assist applications. A variety of sensor types can be used with the portable unit, including force sensitive resistor based foot switches and NMES based accelerometer and gyroscope devices. The paper provides a detailed description of the hardware and block-level system design for both units. The programming and operating procedures for the system are also presented. Finally, functional bench test results for the system are presented.
Manycore Performance-Portability: Kokkos Multidimensional Array Library
Edwards, H. Carter; Sunderland, Daniel; Porter, Vicki; ...
2012-01-01
Large, complex scientific and engineering application code have a significant investment in computational kernels to implement their mathematical models. Porting these computational kernels to the collection of modern manycore accelerator devices is a major challenge in that these devices have diverse programming models, application programming interfaces (APIs), and performance requirements. The Kokkos Array programming model provides library-based approach to implement computational kernels that are performance-portable to CPU-multicore and GPGPU accelerator devices. This programming model is based upon three fundamental concepts: (1) manycore compute devices each with its own memory space, (2) data parallel kernels and (3) multidimensional arrays. Kernel executionmore » performance is, especially for NVIDIA® devices, extremely dependent on data access patterns. Optimal data access pattern can be different for different manycore devices – potentially leading to different implementations of computational kernels specialized for different devices. The Kokkos Array programming model supports performance-portable kernels by (1) separating data access patterns from computational kernels through a multidimensional array API and (2) introduce device-specific data access mappings when a kernel is compiled. An implementation of Kokkos Array is available through Trilinos [Trilinos website, http://trilinos.sandia.gov/, August 2011].« less
Wireless gyroscope platform enabled by a portable media device for quantifying wobble board therapy.
LeMoyne, Robert; Mastroianni, Timothy
2017-07-01
The wobble board enables a therapy strategy for rehabilitation of the ankle foot complex. Quantification of therapy, such as through the use of a wobble board, can facilitate a therapist's acuity for advancing and optimizing the overall therapy strategy. The portable media device, such as an iPod, can be equipped with a software application to function as a wireless gyroscope platform. Integration of the wobble board with the portable media device functioning as a wireless gyroscope enables the potential for patient to therapist interaction through connectivity to the Internet. A patient can conduct wobble board therapy for the ankle foot complex from the convenient vantage point of a homebound setting with therapy data transmitted wirelessly as email attachments. The gyroscope signal of the wobble board therapy can be consolidated into a feature set for machine learning classification. Using a multilayer perceptron neural network considerable classification accuracy has been achieved for differentiating between a hemiplegic affected ankle and unaffected ankle while using a wobble board. The combination of machine learning, wireless systems, such as a portable media device functioning as a wireless gyroscope, and a conventional therapy device, such as a wobble board, are envisioned to advance the capability to optimally impact the rehabilitation experience.
Finger-triggered portable PDMS suction cup for equipment-free microfluidic pumping
NASA Astrophysics Data System (ADS)
Lee, Sanghyun; Kim, Hojin; Lee, Wonhyung; Kim, Joonwon
2018-12-01
This study presents a finger-triggered portable polydimethylsiloxane suction cup that enables equipment-free microfluidic pumping. The key feature of this method is that its operation only involves a "pressing-and-releasing" action for the cup placed at the outlet of a microfluidic device, which transports the fluid at the inlet toward the outlet through a microchannel. This method is simple, but effective and powerful. The cup is portable and can easily be fabricated from a three-dimensional printed mold, used without any pre-treatment, reversibly bonded to microfluidic devices without leakage, and applied to various material-based microfluidic devices. The effect of the suction cup geometry and fabrication conditions on the pumping performance was investigated. Furthermore, we demonstrated the practical applications of the suction cup by conducting an equipment-free pumping of thermoplastic-based microfluidic devices and water-in-oil droplet generation.
NASA Technical Reports Server (NTRS)
Kadivar, Zahra; Beck, Christopher E.; Rovekamp, Roger N.; O'Malley, Marcia K.; Joyce, Charles A.
2016-01-01
Treatment intensity has a profound effect on motor recovery following neurological injury. The use of robotics has potential to automate these labor-intensive therapy procedures that are typically performed by physical therapists. Further, the use of wearable robotics offers an aspect of portability that may allow for rehabilitation outside the clinic. The authors have developed a soft, portable, lightweight upper extremity wearable robotic device to provide motor rehabilitation of patients with affected upper limbs due to traumatic brain injury (TBI). A key feature of the device demonstrated in this paper is the isolation of shoulder and elbow movements necessary for effective rehabilitation interventions. Herein is presented a feasibility study with one subject and demonstration of the device's ability to provide safe, comfortable, and controlled upper extremity movements. Moreover, it is shown that by decoupling shoulder and elbow motions, desired isolated joint actuation can be achieved.
Wide-area-distributed storage system for a multimedia database
NASA Astrophysics Data System (ADS)
Ueno, Masahiro; Kinoshita, Shigechika; Kuriki, Makato; Murata, Setsuko; Iwatsu, Shigetaro
1998-12-01
We have developed a wide-area-distribution storage system for multimedia databases, which minimizes the possibility of simultaneous failure of multiple disks in the event of a major disaster. It features a RAID system, whose member disks are spatially distributed over a wide area. Each node has a device, which includes the controller of the RAID and the controller of the member disks controlled by other nodes. The devices in the node are connected to a computer, using fiber optic cables and communicate using fiber-channel technology. Any computer at a node can utilize multiple devices connected by optical fibers as a single 'virtual disk.' The advantage of this system structure is that devices and fiber optic cables are shared by the computers. In this report, we first described our proposed system, and a prototype was used for testing. We then discussed its performance; i.e., how to read and write throughputs are affected by data-access delay, the RAID level, and queuing.
Image processing for navigation on a mobile embedded platform
NASA Astrophysics Data System (ADS)
Preuss, Thomas; Gentsch, Lars; Rambow, Mark
2006-02-01
Mobile computing devices such as PDAs or cellular phones may act as "Personal Multimedia Exchanges", but they are limited in their processing power as well as in their connectivity. Sensors as well as cellular phones and PDAs are able to gather multimedia data, e. g. images, but leak computing power to process that data on their own. Therefore, it is necessary, that these devices connect to devices with more performance, which provide e.g. image processing services. In this paper, a generic approach is presented that connects different kinds of clients with each other and allows them to interact with more powerful devices. This architecture, called BOSPORUS, represents a communication framework for dynamic peer-to-peer computing. Each peer offers and uses services in this network and communicates loosely coupled and asynchronously with the others. These features make BOSPORUS a service oriented network architecture (SONA). A mobile embedded system, which uses external services for image processing based on the BOSPORUS Framework is shown as an application of the BOSPORUS framework.
Effects of portable computing devices on posture, muscle activation levels and efficiency.
Werth, Abigail; Babski-Reeves, Kari
2014-11-01
Very little research exists on ergonomic exposures when using portable computing devices. This study quantified muscle activity (forearm and neck), posture (wrist, forearm and neck), and performance (gross typing speed and error rates) differences across three portable computing devices (laptop, netbook, and slate computer) and two work settings (desk and computer) during data entry tasks. Twelve participants completed test sessions on a single computer using a test-rest-test protocol (30min of work at one work setting, 15min of rest, 30min of work at the other work setting). The slate computer resulted in significantly more non-neutral wrist, elbow and neck postures, particularly when working on the sofa. Performance on the slate computer was four times less than that of the other computers, though lower muscle activity levels were also found. Potential or injury or illness may be elevated when working on smaller, portable computers in non-traditional work settings. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Song, Zhen-xing; Wu, Tai-hu; Meng, Xing-ju; Lu, Heng-zhi; Zheng, Jie-wen; Wang, Hai-tao
2012-06-01
To describe a portable life support device for transportation of pre-hospital patients with critical illness. The characteristics and requirements for urgent management during transportation of critically ill patients to a hospital were analyzed. With adoption of the original equipment, with the aid of staple of the art soft ware, the overall structure, its installation, fixation, freedom from interference, operational function were studied, and the whole system of life support and resuscitation was designed. The system was composed by different modules, including mechanical ventilation, transfusion, aspiration, critical care, oxygen supply and power supply parts. The system could be fastened quickly to a stretcher to form portable intensive care unit (ICU), and it could be carried by different size vehicles to provide nonstop treatment by using power supply of the vehicle, thus raising the efficiency of urgent care. With characteristics of its small size, lightweight and portable, the device is particularly suitable for narrow space and extreme environment.
Dynamic storage in resource-scarce browsing multimedia applications
NASA Astrophysics Data System (ADS)
Elenbaas, Herman; Dimitrova, Nevenka
1998-10-01
In the convergence of information and entertainment there is a conflict between the consumer's expectation of fast access to high quality multimedia content through narrow bandwidth channels versus the size of this content. During the retrieval and information presentation of a multimedia application there are two problems that have to be solved: the limited bandwidth during transmission of the retrieved multimedia content and the limited memory for temporary caching. In this paper we propose an approach for latency optimization in information browsing applications. We proposed a method for flattening hierarchically linked documents in a manner convenient for network transport over slow channels to minimize browsing latency. Flattening of the hierarchy involves linearization, compression and bundling of the document nodes. After the transfer, the compressed hierarchy is stored on a local device where it can be partly unbundled to fit the caching limits at the local site while giving the user availability to the content.
Díaz, Manuel; Rubio, Bartolomé; Van den Abeele, Floris
2018-01-01
Currently, applications in the Internet of Things (IoT) are tightly coupled to the underlying physical devices. As a consequence, upon adding a device, device replacement or user’s relocation to a different physical space, application developers have to re-perform installation and configuration processes to reconfigure applications, which bears costs in time and knowledge of low-level details. In the emerging IoT field, this issue is even more challenging due to its current unpredictable growth in term of applications and connected devices. In addition, IoT applications can be personalised to each end user and can be present in different environments. As a result, IoT scenarios are very changeable, presenting a challenge for IoT applications. In this paper we present Appdaptivity, a system that enables the development of portable device-decoupled applications that can be adapted to changing contexts. Through Appdaptivity, application developers can intuitively create portable and personalised applications, disengaging from the underlying physical infrastructure. Results confirms a good scalability of the system in terms of connected users and components involved. PMID:29701698
Martín, Cristian; Hoebeke, Jeroen; Rossey, Jen; Díaz, Manuel; Rubio, Bartolomé; Van den Abeele, Floris
2018-04-26
Currently, applications in the Internet of Things (IoT) are tightly coupled to the underlying physical devices. As a consequence, upon adding a device, device replacement or user’s relocation to a different physical space, application developers have to re-perform installation and configuration processes to reconfigure applications, which bears costs in time and knowledge of low-level details. In the emerging IoT field, this issue is even more challenging due to its current unpredictable growth in term of applications and connected devices. In addition, IoT applications can be personalised to each end user and can be present in different environments. As a result, IoT scenarios are very changeable, presenting a challenge for IoT applications. In this paper we present Appdaptivity, a system that enables the development of portable device-decoupled applications that can be adapted to changing contexts. Through Appdaptivity, application developers can intuitively create portable and personalised applications, disengaging from the underlying physical infrastructure. Results confirms a good scalability of the system in terms of connected users and components involved.
A portable device for calibration of autocollimators with nanoradian precision
NASA Astrophysics Data System (ADS)
Yandayan, Tanfer
2017-09-01
A portable device has been developed in TUBITAK UME to calibrate high precision autocollimators with nanoradian precision. The device can operate in the range of +/-4500" which is far enough for the calibration of the available autocollimators and can generate ultra-small angles in measurement steps of 0.0005" (2.5 nrad). Description of the device with the performance tests using the calibrated precise autocollimators and novel methods will be reported. The test results indicate that the device is a good candidate for application to on-site/in-situ calibration of autocollimators with expanded uncertainties of 0.01" (50 nrad) particularly those used in slope measuring profilers.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-26
... Not Permit Floor Brokers To Use Personal Portable Phone Devices on the Trading Floor Following the Aftermath of Hurricane Sandy Until the Earlier of When Phone Service Is Fully Restored or Friday, March 29...--Equities and 36.21--Equities that would not permit Floor brokers to use personal portable phone devices on...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-27
... Would Not Permit Floor Brokers To Use Personal Portable Phone Devices on the Trading Floor Following the Aftermath of Hurricane Sandy Until the Earlier of When Phone Service is Fully Restored or Friday, December... of Rules 36.20 and 36.21 that would not permit Floor brokers to use personal portable phone devices...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-19
... Would Not Permit Floor Brokers To Use Personal Portable Phone Devices on the Trading Floor Following the Aftermath of Hurricane Sandy Until the Earlier of When Phone Service Is Fully Restored or Friday, November... of Rules 36.20 and 36.21 that would not permit Floor brokers to use personal portable phone devices...
ERIC Educational Resources Information Center
Fligor, Brian J.; Levey, Sandra; Levey, Tania
2014-01-01
Purpose: This study examined listening levels and duration of portable listening devices (PLDs) used by people with diversity of ethnicity, education, music genre, and PLD manufacturer. The goal was to estimate participants' PLD noise exposure and identify factors influencing user behavior. Method: This study measured listening levels of 160…
Neumann, Thomas; Baum, Anne Katrin; Baum, Ulrike; Deike, Renate; Feistner, Helmut; Hinrichs, Hermann; Stokes, Joseph; Robra, Bernt-Peter
2018-01-01
The HOME ONE study is part of the larger HOME project, which aims to provide evidence of diagnostic and therapeutic yield ("change of management") of a patient-controlled portable EEG device with dry electrodes for the purposes of EEG home-monitoring neurological outpatients. The HOME ONE study is the first step in the process of investigating whether outpatient EEG home-monitoring changes the diagnosis and treatment of patients in comparison to conventional EEG ("change of management"). Both EEG devices (conventional and portable) will be systematically compared via a two-phase intra-individual assessment.In the first phase (pilot study phase), both EEG devices will be used within neurologist practices (all other things being equal). This pilot study (involving 130 patients) will evaluate the technical usability and efficacy of the new portable dry electrode EEG recorder in comparison to conventional EEG devices. Judgements will be based on technical assessments and EEG record examinations of private practitioners and two experienced neurologists (percent of concordant readings and kappa values).The second phase (feasibility study phase) aims to assess patients' acceptability and feasibility of the EEG home-monitoring and will provide insights into the extent diagnostic and therapeutic yields can be expected.For this purpose, a conventional EEG will be recorded in neurologist practices. Thereafter, the practice staff will instruct the patients on how the portable EEG device functions. The patients will subsequently use the devices in their home environment.The evaluation will compare the before and after documented diagnostic findings and the therapeutic consequences of the private practitioners with those of two experienced neurologists. To the best of our knowledge, this will be the first study of its kind to examine new approaches to diagnosing unclear consciousness disorders or other disorders of the CNS or the cardiovascular system through the use of a patient-controlled portable EEG device with dry electrodes for the purpose of home-monitoring neurological outpatients. If the two phases of the HOME ONE study provide sufficient evidence of diagnostic and therapeutic yields, this would justify (indication-specific) full-scale randomized controlled trials or observational studies. DRKS DRKS00012685. Registered 9 August 2017, retrospectively registered.
Inexpensive portable drug detector
NASA Technical Reports Server (NTRS)
Dimeff, J.; Heimbuch, A. H.; Parker, J. A.
1977-01-01
Inexpensive, easy-to-use, self-scanning, self-calibrating, portable unit automatically graphs fluorescence spectrum of drug sample. Device also measures rate of movement through chromatographic column for forensic and medical testing.
Multimedia-assisted breathwalk-aware system.
Yu, Meng-Chieh; Wu, Huan; Lee, Ming-Sui; Hung, Yi-Ping
2012-12-01
Breathwalk is a science of combining specific patterns of footsteps synchronized with the breathing. In this study, we developed a multimedia-assisted Breathwalk-aware system which detects user's walking and breathing conditions and provides appropriate multimedia guidance on the smartphone. Through the mobile device, the system enhances user's awareness of walking and breathing behaviors. As an example application in slow technology, the system could help meditator beginners learn "walking meditation," a type of meditation which aims to be as slow as possible in taking pace, to synchronize footstep with breathing, and to land every footstep with toes first. In the pilot study, we developed a walking-aware system and evaluated whether multimedia-assisted mechanism is capable of enhancing beginner's walking awareness while walking meditation. Experimental results show that it could effectively assist beginners in slowing down the walking speed and decreasing incorrect footsteps. In the second experiment, we evaluated the Breathwalk-aware system to find a better feedback mechanism for learning the techniques of Breathwalk while walking meditation. The experimental results show that the visual-auditory mechanism is a better multimedia-assisted mechanism while walking meditation than visual mechanism and auditory mechanism.
SkinScan©: A PORTABLE LIBRARY FOR MELANOMA DETECTION ON HANDHELD DEVICES
Wadhawan, Tarun; Situ, Ning; Lancaster, Keith; Yuan, Xiaojing; Zouridakis, George
2011-01-01
We have developed a portable library for automated detection of melanoma termed SkinScan© that can be used on smartphones and other handheld devices. Compared to desktop computers, embedded processors have limited processing speed, memory, and power, but they have the advantage of portability and low cost. In this study we explored the feasibility of running a sophisticated application for automated skin cancer detection on an Apple iPhone 4. Our results demonstrate that the proposed library with the advanced image processing and analysis algorithms has excellent performance on handheld and desktop computers. Therefore, deployment of smartphones as screening devices for skin cancer and other skin diseases can have a significant impact on health care delivery in underserved and remote areas. PMID:21892382
Mather, Carey; Cummings, Elizabeth; Allen, Penny
2014-12-10
The growth of digital technology has created challenges for safe and appropriate use of mobile or portable devices during work-integrated learning (WIL) in health care environments. Personal and professional use of technology has outpaced the development of policy or codes of practice for guiding its use at the workplace. There is a perceived risk that portable devices may distract from provision of patient or client care if used by health professionals or students during employment or WIL. This study aimed to identify differences in behavior of undergraduate nurses in accessing information, using a portable or mobile device, when undertaking WIL compared to other non-work situations. A validated online survey was administered to students while on placement in a range of health care settings in two Australian states. There were 84 respondents, with 56% (n=47) reporting access to a mobile or portable device. Differences in use of a mobile device away from, compared with during WIL, were observed for non-work related activities such as messaging (P<.001), social networking (P<.001), shopping on the Internet (P=.01), conducting personal business online (P=.01), and checking or sending non-work related texts or emails to co-workers (P=.04). Study-related activities were conducted more regularly away from the workplace and included accessing University sites for information (P=.03) and checking or sending study-related text messages or emails to friends or co-workers (P=.01). Students continued to access nursing, medical, professional development, and study-related information away from the workplace. Undergraduate nurses limit their access to non-work or non-patient centered information while undertaking WIL. Work-related mobile learning is being undertaken, in situ, by the next generation of nurses who expect easy access to mobile or portable devices at the workplace, to ensure safe and competent care is delivered to their patients.
2014-01-01
Background The growth of digital technology has created challenges for safe and appropriate use of mobile or portable devices during work-integrated learning (WIL) in health care environments. Personal and professional use of technology has outpaced the development of policy or codes of practice for guiding its use at the workplace. There is a perceived risk that portable devices may distract from provision of patient or client care if used by health professionals or students during employment or WIL. Objective This study aimed to identify differences in behavior of undergraduate nurses in accessing information, using a portable or mobile device, when undertaking WIL compared to other non-work situations. Methods A validated online survey was administered to students while on placement in a range of health care settings in two Australian states. Results There were 84 respondents, with 56% (n=47) reporting access to a mobile or portable device. Differences in use of a mobile device away from, compared with during WIL, were observed for non-work related activities such as messaging (P<.001), social networking (P<.001), shopping on the Internet (P=.01), conducting personal business online (P=.01), and checking or sending non-work related texts or emails to co-workers (P=.04). Study-related activities were conducted more regularly away from the workplace and included accessing University sites for information (P=.03) and checking or sending study-related text messages or emails to friends or co-workers (P=.01). Students continued to access nursing, medical, professional development, and study-related information away from the workplace. Conclusions Undergraduate nurses limit their access to non-work or non-patient centered information while undertaking WIL. Work-related mobile learning is being undertaken, in situ, by the next generation of nurses who expect easy access to mobile or portable devices at the workplace, to ensure safe and competent care is delivered to their patients. PMID:25499736
Design of a multimedia gateway for mobile devices
NASA Astrophysics Data System (ADS)
Hens, Raf; Goeminne, Nico; Van Hoecke, Sofie; Verdickt, Tom; Bouve, Thomas; Gielen, Frank; Demeester, Piet
2005-03-01
Although mobile users are currently offered a lot more capabilities on their mobile devices, they still experience some limitations. They can surf the Internet, read their e-mail and receive MMS messages, but they have limited processing power, storage capacity and bandwidth and are limited in their access to peripherals (e.g. printers). We have designed and implemented a multimedia gateway for mobile devices that reduces these limitations. It gives the mobile devices transparent access to high capacity devices connected to the gateway, which is built around a central, modularly extensible server that can run on any PC or home gateway. It manages two sets of modules: one set offering the actual services and another set handling the IP-based wireless interaction with the client applications on the mobile devices. These modules can be added and removed dynamically, offering new services on the fly. Currently services for storage, printing, domotics and playing music are provided. Others can easily be added later on. This paper discusses the architecture and development, the management of modules, the actual services and their benefits. Besides a proprietary implementation, it also looks into OSGi and how both platforms compare to each other, concerning design, architecture, ease of development, functionality, ...
McHenry, Megan S; Fischer, Lydia J; Chun, Yeona; Vreeman, Rachel C
2017-08-01
The objective of this study is to conduct a systematic review of the literature of how portable electronic technologies with offline functionality are perceived and used to provide health education in resource-limited settings. Three reviewers evaluated articles and performed a bibliography search to identify studies describing health education delivered by portable electronic device with offline functionality in low- or middle-income countries. Data extracted included: study population; study design and type of analysis; type of technology used; method of use; setting of technology use; impact on caregivers, patients, or overall health outcomes; and reported limitations. Searches yielded 5514 unique titles. Out of 75 critically reviewed full-text articles, 10 met inclusion criteria. Study locations included Botswana, Peru, Kenya, Thailand, Nigeria, India, Ghana, and Tanzania. Topics addressed included: development of healthcare worker training modules, clinical decision support tools, patient education tools, perceptions and usability of portable electronic technology, and comparisons of technologies and/or mobile applications. Studies primarily looked at the assessment of developed educational modules on trainee health knowledge, perceptions and usability of technology, and comparisons of technologies. Overall, studies reported positive results for portable electronic device-based health education, frequently reporting increased provider/patient knowledge, improved patient outcomes in both quality of care and management, increased provider comfort level with technology, and an environment characterized by increased levels of technology-based, informal learning situations. Negative assessments included high investment costs, lack of technical support, and fear of device theft. While the research is limited, portable electronic educational resources present promising avenues to increase access to effective health education in resource-limited settings, contingent on the development of culturally adapted and functional materials to be used on such devices.
Student Acceptance of Clickers in Large Introductory Business Classes
ERIC Educational Resources Information Center
Preis, Michael W.; Kellar, Gregory M.; Crosby, Elizabeth
2011-01-01
Today's NetGen students require more multimedia and interactive learning environments and greater participation than previous generations. Personal response devices (PRDs, sometimes called Audience Response Devices or ARDs, better known as clickers) show promise in helping to meet that need. This article explores the literature of PRDs to develop…
40 CFR Table 4 to Subpart Zzzz of... - Requirements for Performance Tests
Code of Federal Regulations, 2010 CFR
2010-07-01
... and outlet of the control device; and (1) Portable CO and O2 analyzer. (a) Using ASTM D6522-00 (2005... control device (1) Portable CO and O2 analyzer. (a) Using ASTM D6522-00 (2005) a,b (incorporated by..., appendix A, or ASTM Method D6522-00 (2005) (a) Measurements to determine O2 concentration must be made at...
Design and Validation of a Low-Cost Portable Device to Quantify Postural Stability.
Zhu, Yong
2017-03-18
Measurement of the displacement of the center-of-pressure (COP) is an important tool used in biomechanics to assess postural stability and human balance. The goal of this research was to design and validate a low-cost portable device that can offer a quick indication of the state of postural stability and human balance related conditions. Approximate entropy (ApEn) values reflecting the amount of irregularity hiding in COP oscillations were used to calculate the index. The prototype adopted a portable design using the measurements of the load cells located at the four corners of a low-cost force platform. The test subject was asked to stand on the device in a quiet, normal, upright stance for 30 s with eyes open and subsequently for 30 s with eyes closed. Based on the COP displacement signals, the ApEn values were calculated. The results indicated that the prototype device was capable of capturing the increase in regularity of postural control in the visual-deprivation conditions. It was also able to decipher the subtle postural control differences along anterior-posterior and medial-lateral directions. The data analysis demonstrated that the prototype would enable the quantification of postural stability and thus provide a low-cost portable device to assess many conditions related to postural stability and human balance such as aging and pathologies.
Chen, Yang; Li, Xu; Xu, Zhan; Li, Zonghua; Zhang, Pengzhi; He, Ya; Wang, Fangyuan; Qiu, Jianhua
2011-06-08
Hearing impairment negatively impacts students' development of academic, language and social skills. Even minimal unilateral hearing loss can hinder educational performance. We investigated the prevalence of ear diseases among secondary school students in the city of Xi'an, China in order to provide a foundation for evidence-based hearing healthcare. A stratified random sampling survey was conducted in 29 secondary schools. Demographics and medical histories were collected, and otologic examinations were performed. Questionnaires were administered to assess insomnia, academic stress and use of portable audio devices. Logistic regression analysis was used to identify factors associated with hearing impairment, and the association of sensorineural hearing loss with insomnia, academic stress and the use of portable audio devices was analyzed with the chi-square test. The percentage of students with some form of ear disease was 3.32%. External ear disease, middle ear disease and sensorineural hearing loss occurred in 1.21%, 0.64% and 1.47% of the students, respectively. Boys had a relatively higher prevalence of ear disease than girls. According to our survey, the prevalence of sensorineural hearing loss increased significantly among the students with insomnia and extended use of portable audio devices, but not among those with elevated levels of academic stress. Hearing aids and surgical treatment were needed in 1.47% and 0.89% of the students, respectively. There is a high prevalence of ear disease among secondary school students, and this should be given more attention. Insomnia and the excessive use of portable audio devices may be related to adolescent sensorineural hearing loss. It is important to establish and comply with an evidence-based preventive strategy.
Marchese, N; Cannuli, A; Caccamo, M T; Pace, C
2017-01-01
Neutron sources are increasingly employed in a wide range of research fields. For some specific purposes an alternative to existing large-scale neutron scattering facilities, can be offered by the new generation of portable neutron devices. This review reports an overview for such recently available neutron generators mainly addressed to biophysics applications with specific reference to portable non-stationary neutron generators applied in Neutron Activation Analysis (NAA). The review reports a description of a typical portable neutron generator set-up addressed to biophysics applications. New generation portable neutron devices, for some specific applications, can constitute an alternative to existing large-scale neutron scattering facilities. Deuterium-Deuterium pulsed neutron sources able to generate 2.5MeV neutrons, with a neutron yield of 1.0×10 6 n/s, a pulse rate of 250Hz to 20kHz and a duty factor varying from 5% to 100%, when combined with solid-state photon detectors, show that this kind of compact devices allow rapid and user-friendly elemental analysis. "This article is part of a Special Issue entitled "Science for Life" Guest Editor: Dr. Austen Angell, Dr. Salvatore Magazù and Dr. Federica Migliardo". Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Weagant, Scott; Karanassios, Vassili
2015-06-01
The use of portable hand held computing devices for the acquisition of spectrochemical data is briefly discussed using examples from the author's laboratory. Several network topologies are evaluated. At present, one topology that involves a portable computing device for data acquisition and spectrometer control and that has wireless access to the internet at one end and communicates with a smart phone at the other end appears to be better suited for "taking part of the lab to the sample" types of applications. Thus, spectrometric data can be accessed from anywhere in the world.
Portable music player users: cultural differences and potential dangers.
Levey, Sandra; Fligor, Brian J; Cutler, Cecelia; Harushimana, Immaculee
2013-01-01
Many studies have examined the use of portable music players portable listening devices (PLDs) from various ethnic groups. Some findings suggest that there may be differences among ethnic groups that lead to louder or longer listening when using PLD devices. For example, some studies found that Hispanic PLD users listen at higher volume levels while other studies found that African American PLD users listen at higher volume levels. No investigator has explained the reasons for differences among ethnic groups in listening intensity. This paper will address the possible reasons for these differences and offer guidelines for the prevention of noise-induced hearing loss.
Using Mobile Devices for Robotic Controllers: Examples and Some Initial Concepts for Experimentation
2011-06-01
3 Figure 3. The Sony PlayStation Portable hand-held control device is about 6.7 × 2.9 × 0.9 in. .... 4 Figure 4 . Current...Nunchuk (left) measures 4.45 × 1.5 × 1.48 in. Figure 2. Apple iPhone is 4.5 × 2.31 × 0.37 in. 4 Figure 3. The Sony PlayStation Portable...YYYY) June 2011 2. REPORT TYPE Final 3. DATES COVERED (From - To) June 2010–July 2010 4 . TITLE AND SUBTITLE Using Mobile Devices for Robotic
Portable two-channel PPG cardiovascular sensor device
NASA Astrophysics Data System (ADS)
Spigulis, Janis; Erts, Renars; Ozols, Maris
2003-10-01
A portable sensor device for simultaneous detection and processing of skin-remitted optical signals from any two sites of the body has been developed and tested. The photoplethysmography (PPG) principle was applied to follow the dilatation and contraction of skin blood vessels during the cardiac cycle. The newly developed two-channel approach allows to estimate the vascular blood flow resistance by analysis of time shifts between the PPG pulses detected at different body sites. Potential of the sensor device for express-assessment of human cardio-vascular condition and for body fitness tests has been demonstrated.
Mastinu, Enzo; Ortiz-Catalan, Max; Hakansson, Bo
2015-01-01
Compact and low-noise Analog Front-Ends (AFEs) are becoming increasingly important for the acquisition of bioelectric signals in portable system. In this work, we compare two popular AFEs available on the market, namely the ADS1299 (Texas Instruments) and the RHA2216 (Intan Technologies). This work develops towards the identification of suitable acquisition modules to design an affordable, reliable and portable device for electromyography (EMG) acquisition and prosthetic control. Device features such as Common Mode Rejection (CMR), Input Referred Noise (IRN) and Signal to Noise Ratio (SNR) were evaluated, as well as the resulting accuracy in myoelectric pattern recognition (MPR) for the decoding of motion intention. Results reported better noise performances and higher MPR accuracy for the ADS1299 and similar SNR values for both devices.
Performances of a portable electrospinning apparatus.
Mouthuy, Pierre-Alexis; Groszkowski, Lukasz; Ye, Hua
2015-05-01
To demonstrate that portable electrospinning devices can spin a wide range of polymers into submicron fibres and provide a mesh quality comparable to those produced with benchtop machines. We have designed a small, battery-operated electrospinning apparatus which enables control over the voltage and the flow rate of the polymer solution via a microcontroller. It can be used to electrospin a range of commonly used polymers including poly(ε-caprolactone), poly(p-dioxanone), poly(lactic-co-glycolic acid), poly(3-hydroxybutyrate), poly(ethylene oxide), poly(vinyl acohol) and poly(vinyl butyral). Moreover, electrospun meshes are produced with a quality comparable to a benchtop machine. We also show that the portable apparatus is able to electrospray beads and microparticles. Finally, we highlight the potential of the device for wound healing applications by demonstrating the possibility of electrospinning onto pig and human skins. Portable electrospinning devices are still at an early stage of development but they could soon become an attractive alternative to benchtop machines, in particular for uses that require mobility and a higher degree of flexibility, such as for wound healing applications.
Feasibility of a portable X-ray fluorescence device for bone lead measurements of condor bones.
Specht, Aaron J; Parish, Chris N; Wallens, Emma K; Watson, Rick T; Nie, Linda H; Weisskopf, Marc G
2018-02-15
Lead based ammunition is a primary source of lead exposure, especially for scavenging wildlife. Lead poisoning remains the leading cause of diagnosed death for the critically endangered California condors, which are annually monitored via blood tests for lead exposure. The results of these tests are helpful in determining recent exposure in condors and in defining the potential for exposure to other species including humans. Since condors are victim to acute and chronic lead exposure, being able to measure both would lend valuable information on the rates of exposure and accumulation through time. A commercial portable X-ray fluorescence (XRF) device has been optimized to measure bone lead in vivo in humans, but this device could also be valuable for field measurements of bone lead in avian species. In this study, we performed measurements of bone Pb in excised, bare condor bones using inductively coupled plasma mass spectrometry (ICP-MS), a cadmium 109 (Cd-109) K-shell X-ray fluorescence (KXRF) system, and a portable XRF system. Both KXRF and portable XRF bone Pb measurement techniques demonstrated good correlations with ICP-MS results (r=0.93 and r=0.92 respectively), even with increasing skin thickness (r=0.86 between ICP-MS and portable XRF at 1.54mm of soft tissue). In conclusion, our results suggest that a portable XRF could be a useful option for measurement of bone Pb in avian species in the field. Copyright © 2017 Elsevier B.V. All rights reserved.
Low Field Squid MRI Devices, Components and Methods
NASA Technical Reports Server (NTRS)
Hahn, Inseob (Inventor); Penanen, Konstantin I. (Inventor); Eom, Byeong H. (Inventor)
2013-01-01
Low field SQUID MRI devices, components and methods are disclosed. They include a portable low field (SQUID)-based MRI instrument and a portable low field SQUID-based MRI system to be operated under a bed where a subject is adapted to be located. Also disclosed is a method of distributing wires on an image encoding coil system adapted to be used with an NMR or MRI device for analyzing a sample or subject and a second order superconducting gradiometer adapted to be used with a low field SQUID-based MRI device as a sensing component for an MRI signal related to a subject or sample.
Low Field Squid MRI Devices, Components and Methods
NASA Technical Reports Server (NTRS)
Penanen, Konstantin I. (Inventor); Eom, Byeong H. (Inventor); Hahn, Inseob (Inventor)
2014-01-01
Low field SQUID MRI devices, components and methods are disclosed. They include a portable low field (SQUID)-based MRI instrument and a portable low field SQUID-based MRI system to be operated under a bed where a subject is adapted to be located. Also disclosed is a method of distributing wires on an image encoding coil system adapted to be used with an NMR or MRI device for analyzing a sample or subject and a second order superconducting gradiometer adapted to be used with a low field SQUID-based MRI device as a sensing component for an MRI signal related to a subject or sample.
Low field SQUID MRI devices, components and methods
NASA Technical Reports Server (NTRS)
Penanen, Konstantin I. (Inventor); Eom, Byeong H. (Inventor); Hahn, Inseob (Inventor)
2011-01-01
Low field SQUID MRI devices, components and methods are disclosed. They include a portable low field (SQUID)-based MRI instrument and a portable low field SQUID-based MRI system to be operated under a bed where a subject is adapted to be located. Also disclosed is a method of distributing wires on an image encoding coil system adapted to be used with an NMR or MRI device for analyzing a sample or subject and a second order superconducting gradiometer adapted to be used with a low field SQUID-based MRI device as a sensing component for an MRI signal related to a subject or sample.
Low field SQUID MRI devices, components and methods
NASA Technical Reports Server (NTRS)
Penanen, Konstantin I. (Inventor); Eom, Byeong H (Inventor); Hahn, Inseob (Inventor)
2010-01-01
Low field SQUID MRI devices, components and methods are disclosed. They include a portable low field (SQUID)-based MRI instrument and a portable low field SQUID-based MRI system to be operated under a bed where a subject is adapted to be located. Also disclosed is a method of distributing wires on an image encoding coil system adapted to be used with an NMR or MRI device for analyzing a sample or subject and a second order superconducting gradiometer adapted to be used with a low field SQUID-based MRI device as a sensing component for an MRI signal related to a subject or sample.
A review of digital microfluidics as portable platforms for lab-on a-chip applications.
Samiei, Ehsan; Tabrizian, Maryam; Hoorfar, Mina
2016-07-07
Following the development of microfluidic systems, there has been a high tendency towards developing lab-on-a-chip devices for biochemical applications. A great deal of effort has been devoted to improve and advance these devices with the goal of performing complete sets of biochemical assays on the device and possibly developing portable platforms for point of care applications. Among the different microfluidic systems used for such a purpose, digital microfluidics (DMF) shows high flexibility and capability of performing multiplex and parallel biochemical operations, and hence, has been considered as a suitable candidate for lab-on-a-chip applications. In this review, we discuss the most recent advances in the DMF platforms, and evaluate the feasibility of developing multifunctional packages for performing complete sets of processes of biochemical assays, particularly for point-of-care applications. The progress in the development of DMF systems is reviewed from eight different aspects, including device fabrication, basic fluidic operations, automation, manipulation of biological samples, advanced operations, detection, biological applications, and finally, packaging and portability of the DMF devices. Success in developing the lab-on-a-chip DMF devices will be concluded based on the advances achieved in each of these aspects.
Speckle-based portable device for in-situ metrology of x-ray mirrors at Diamond Light Source
NASA Astrophysics Data System (ADS)
Wang, Hongchang; Kashyap, Yogesh; Zhou, Tunhe; Sawhney, Kawal
2017-09-01
For modern synchrotron light sources, the push toward diffraction-limited and coherence-preserved beams demands accurate metrology on X-ray optics. Moreover, it is important to perform in-situ characterization and optimization of X-ray mirrors since their ultimate performance is critically dependent on the working conditions. Therefore, it is highly desirable to develop a portable metrology device, which can be easily implemented on a range of beamlines for in-situ metrology. An X-ray speckle-based portable device for in-situ metrology of synchrotron X-ray mirrors has been developed at Diamond Light Source. Ultra-high angular sensitivity is achieved by scanning the speckle generator in the X-ray beam. In addition to the compact setup and ease of implementation, a user-friendly graphical user interface has been developed to ensure that characterization and alignment of X-ray mirrors is simple and fast. The functionality and feasibility of this device is presented with representative examples.
Bilgin, Cahit; Erkorkmaz, Unal; Ucar, Muhammed Kursad; Akin, Nese; Nalbant, Ahmet; Annakkaya, Ali Nihat
2016-01-01
Polysomnography (PSG) remains the gold standard for the diagnosis of obstructive sleep apnoea syndrome (OSAS). While PSG is essential for OSAS, this technique is not suitable for epidemiological investigation due to its high cost. This study aimed to compare a portable monitoring device with PSG for the measurement of parameters related to the diagnosis of OSAS in rural areas. We conducted a descriptive study of 155 patients (30 women and 125 men; mean age, 52±12years) who visited to the Hendek Government Hospital Sleep Laboratory between February 2011 and January 2013 Apnoea hypopnea index (AHI), mean levels of O2 (meanO2), desaturation index (DI), and minimum oxygen saturation (minO2) variations as measured using both PSG and a portable Somnocheck Micro (SM) device were compared. Differences were found between the meanO2 and DI, but not between AHI and minO2. Differences between the methods were not desired, but the relationship between the methods was distinct and supported our hypothesis. The results of our study have shown that the SM portable device can be used as an alternative diagnostic tool in this population either at home or in sleep clinic.
Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok
2014-07-07
To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-01
... parties, the Commission has determined to review (1) The claim construction of the limitation ``second... patent, (3) the claim construction of the limitations ``extracting means'' and ``a calculating device... different formats? Please provide support for your claim construction in the claims, the specification, the...
Cardiovascular fitness strengthening using portable device.
Alqudah, Hamzah; Kai Cao; Tao Zhang; Haddad, Azzam; Su, Steven; Celler, Branko; Nguyen, Hung T
2016-08-01
The paper describes a reliable and valid Portable Exercise Monitoring system developed using TI eZ430-Chronos watch, which can control the exercise intensity through audio stimulation in order to increase the Cardiovascular fitness strengthening.
Lauretti, Gabriela R; Oliveira, Raquel; Parada, Flavia; Mattos, Anita L
2015-08-01
Transcutaneous electrical nerve stimulation (TENS) is an established method for pain relief in dysmenorrhea. A feasible advantage would be the study of a portable device. The purpose of the study was to evaluate the effectiveness and safety of a new portable TENS device (TANYX®) for menstruation cramps. Forty women were evaluated in a double-blind, prospective, randomized fashion, divided into sham and active groups. TENS was applied medially at the suprapubic region, for 30-min duration at eight-hour intervals, up to seven days. The placebo group (PG) received sham device. The TENS group (TG) applied an active 85 Hz frequency TENS. Efficacy measures were pain relief evaluated on a visual analog scale (VAS) and diclofenac intake, and quality of life represented by: 1) capacity to get out of the bed, 2) food or drink intake, 3) missing routine daily activities such as work or school, and 4) quality of sleep. The active TENS device induced a prompt onset of pain relief in a strictly segmental manner nearby the dermatomes where the TENS was applied at the skin, and there was a drop in mean pain score from 8 to 2 cm (p < 0.001). Diclofenac consumption was also significantly reduced (p < 0.01), compared with the PG. Quality of life improved significantly in TG when compared with PG (p < 0.05). Three months after the beginning of the study, 14/20 of the women were still using the active device regularly. No adverse effects were observed. The portable, disposable, active TENS device induced a prompt onset of pain relief and improved the quality of life, without adverse effects, in patients with painful cramps associated with dysmenorrhea. © 2015 International Neuromodulation Society.
A portable device for detecting fruit quality by diffuse reflectance Vis/NIR spectroscopy
NASA Astrophysics Data System (ADS)
Sun, Hongwei; Peng, Yankun; Li, Peng; Wang, Wenxiu
2017-05-01
Soluble solid content (SSC) is a major quality parameter to fruit, which has influence on its flavor or texture. Some researches on the on-line non-invasion detection of fruit quality were published. However, consumers desire portable devices currently. This study aimed to develop a portable device for accurate, real-time and nondestructive determination of quality factors of fruit based on diffuse reflectance Vis/NIR spectroscopy (520-950 nm). The hardware of the device consisted of four units: light source unit, spectral acquisition unit, central processing unit, display unit. Halogen lamp was chosen as light source. When working, its hand-held probe was in contact with the surface of fruit samples thus forming dark environment to shield the interferential light outside. Diffuse reflectance light was collected and measured by spectrometer (USB4000). ARM (Advanced RISC Machines), as central processing unit, controlled all parts in device and analyzed spectral data. Liquid Crystal Display (LCD) touch screen was used to interface with users. To validate its reliability and stability, 63 apples were tested in experiment, 47 of which were chosen as calibration set, while others as prediction set. Their SSC reference values were measured by refractometer. At the same time, samples' spectral data acquired by portable device were processed by standard normalized variables (SNV) and Savitzky-Golay filter (S-G) to eliminate the spectra noise. Then partial least squares regression (PLSR) was applied to build prediction models, and the best predictions results was achieved with correlation coefficient (r) of 0.855 and standard error of 0.6033° Brix. The results demonstrated that this device was feasible to quantitatively analyze soluble solid content of apple.
Suomalainen, A; Brüllmann, D; Jacobs, R; Horner, K; Stamatakis, H C
2015-01-01
Handheld portable X-ray devices are increasingly used for intraoral radiography. This development introduces new challenges to staff and patient safety, for which new or revised risk assessments must be made and acted upon prior to use. Major issues might be: difficulties in using rectangular collimation with beam aiming devices, more complex matching of exposure settings to the X-ray receptor used (e.g. longer exposure times), movements owing to the units' weight, protection of the operator and third persons, and the use in uncontrolled environments. These problems may result in violation of the “as low as reasonably achievable’’, that is, ALARA principle by an increase in (re)exposures compared with the other available intraoral X-ray devices. Hence, the use of handheld portable X-ray devices should be considered only after careful and documented evaluation (which might be performed based on medical physics support), when there is evidence that handheld operation has benefits over traditional modalities and when no new risks to the operators and/or third parties are caused. It is expected that the use of handheld portable X-ray devices will be very exceptional, and for justified situations only. Special attention should be drawn to beam-aiming devices, rectangular collimation, the section of the X-ray receptor, focus–skin distance, and backscatter shielding, and that the unit delivers reproducible dose over the full set of environmental conditions (e.g. battery status and temperature). PMID:25710118
A Survey on Multimedia-Based Cross-Layer Optimization in Visual Sensor Networks
Costa, Daniel G.; Guedes, Luiz Affonso
2011-01-01
Visual sensor networks (VSNs) comprised of battery-operated electronic devices endowed with low-resolution cameras have expanded the applicability of a series of monitoring applications. Those types of sensors are interconnected by ad hoc error-prone wireless links, imposing stringent restrictions on available bandwidth, end-to-end delay and packet error rates. In such context, multimedia coding is required for data compression and error-resilience, also ensuring energy preservation over the path(s) toward the sink and improving the end-to-end perceptual quality of the received media. Cross-layer optimization may enhance the expected efficiency of VSNs applications, disrupting the conventional information flow of the protocol layers. When the inner characteristics of the multimedia coding techniques are exploited by cross-layer protocols and architectures, higher efficiency may be obtained in visual sensor networks. This paper surveys recent research on multimedia-based cross-layer optimization, presenting the proposed strategies and mechanisms for transmission rate adjustment, congestion control, multipath selection, energy preservation and error recovery. We note that many multimedia-based cross-layer optimization solutions have been proposed in recent years, each one bringing a wealth of contributions to visual sensor networks. PMID:22163908
Implementation of a portable device for real-time ECG signal analysis.
Jeon, Taegyun; Kim, Byoungho; Jeon, Moongu; Lee, Byung-Geun
2014-12-10
Cardiac disease is one of the main causes of catastrophic mortality. Therefore, detecting the symptoms of cardiac disease as early as possible is important for increasing the patient's survival. In this study, a compact and effective architecture for detecting atrial fibrillation (AFib) and myocardial ischemia is proposed. We developed a portable device using this architecture, which allows real-time electrocardiogram (ECG) signal acquisition and analysis for cardiac diseases. A noisy ECG signal was preprocessed by an analog front-end consisting of analog filters and amplifiers before it was converted into digital data. The analog front-end was minimized to reduce the size of the device and power consumption by implementing some of its functions with digital filters realized in software. With the ECG data, we detected QRS complexes based on wavelet analysis and feature extraction for morphological shape and regularity using an ARM processor. A classifier for cardiac disease was constructed based on features extracted from a training dataset using support vector machines. The classifier then categorized the ECG data into normal beats, AFib, and myocardial ischemia. A portable ECG device was implemented, and successfully acquired and processed ECG signals. The performance of this device was also verified by comparing the processed ECG data with high-quality ECG data from a public cardiac database. Because of reduced computational complexity, the ARM processor was able to process up to a thousand samples per second, and this allowed real-time acquisition and diagnosis of heart disease. Experimental results for detection of heart disease showed that the device classified AFib and ischemia with a sensitivity of 95.1% and a specificity of 95.9%. Current home care and telemedicine systems have a separate device and diagnostic service system, which results in additional time and cost. Our proposed portable ECG device provides captured ECG data and suspected waveform to identify sporadic and chronic events of heart diseases. This device has been built and evaluated for high quality of signals, low computational complexity, and accurate detection.
Discharge of thoracic patients on portable digital suction: Is it cost-effective?
Southey, Dawn; Pullinger, Diane; Loggos, Spiros; Kumari, Nelam; Lengyel, Emma; Morgan, Ian; Yiu, Patrick; Nandi, Jayanta; Luckraz, Heyman
2015-09-01
A portable suction drainage device for patients undergoing thoracic surgical procedures was introduced into our service in January 2010. Patients who met strict discharge criteria were allowed to continue their treatment at home with the device. They were monitored in a designated follow-up clinic. Data were collected to identify the impact of this service in relation to the duration of follow-up required, bed-days saved, and potential cost/benefits. All patients who underwent a thoracic procedure from March 2012 to April 2014 and required suction postoperatively for air leak were included in the study. Patients were identified as suitable according to the discharge criteria. Data regarding patient demographics were collected prospectively on the thoracic database, and data on the drainage device were logged in a specific data sheet. Visits to the follow-up clinic were also recorded. During the study period, 50 patients stayed a total 1125 days on the portable suction system. Twenty were discharged home, equating to 772 bed-days saved (GBP 270,000 cost-saving). Clinic attendance totalled 162 visits (GBP 24,300 cost reimbursement for attendance). Six (30%) patients were readmitted on 9 occasions due to device malfunction or inability to cope at home. Careful identification of patients suitable for discharge with a portable suction device achieved a significant cost-saving and freed hospital beds, thus allowing increased surgical activity. Patients were also able to be cared for within their home environment and maintain their quality of life. © The Author(s) 2015.
Kao, Peng-Kai; Hsu, Cheng-Che
2014-09-02
A portable microplasma generation device (MGD) operated in ambient air is introduced for making a microfluidic paper-based analytical device (μPAD) that serves as a primary healthcare platform. By utilizing a printed circuit board fabrication process, a flexible and lightweight MGD can be fabricated within 30 min with ultra low-cost. This MGD can be driven by a portable power supply (less than two pounds), which can be powered using 12 V-batteries or ac-dc converters. This MGD is used to perform maskless patterning of hydrophilic patterns with sub-millimeter spatial resolution on hydrophobic paper substrates with good pattern transfer fidelity. Using this MGD to fabricate μPADs is demonstrated. With a proper design of the MGD electrode geometry, μPADs with 500-μm-wide flow channels can be fabricated within 1 min and with a cost of less than $USD 0.05/device. We then test the μPADs by performing quantitative colorimetric assay tests and establish a calibration curve for detection of glucose and nitrite. The results show a linear response to a glucose assay for 1-50 mM and a nitrite assay for 0.1-5 mM. The low cost, miniaturized, and portable MGD can be used to fabricate μPADs on demand, which is suitable for in-field diagnostic tests. We believe this concept brings impact to the field of biomedical analysis, environmental monitoring, and food safety survey.
STS-41 Commander Richards uses DTO 1206 portable computer onboard OV-103
NASA Technical Reports Server (NTRS)
1990-01-01
STS-41 Commander Richard N. Richards, at pilots station, uses Detailed Test Objective (DTO) Space Station Cursor Control Device Evaluation MACINTOSH portable computer on the forward flight deck of Discovery, Orbiter Vehicle (OV) 103. Richards tests the roller ball cursor control device. Surrounding Richards are checklists, forward flight deck windows, his lightweight communications kit assembly headset, a beverage container (orange-mango drink), and the pilots seat back and headrest.
Personal Portable Devices in the Light of the Internet of Things.
Lhotska, Lenka; Stechova, Katerina; Pharow, Peter
2017-01-01
Personal portable devices have already gained their position in health services. However, mobile technologies and Internet of Things open new areas of applications. The possibility to collect many data types continuously over long time intervals brings various questions that must be answered in the design process. We also discuss briefly the role of the user. We illustrate the complexity of the field by a case study of diabetes management.
Portable smartphone based quantitative phase microscope
NASA Astrophysics Data System (ADS)
Meng, Xin; Tian, Xiaolin; Yu, Wei; Kong, Yan; Jiang, Zhilong; Liu, Fei; Xue, Liang; Liu, Cheng; Wang, Shouyu
2018-01-01
To realize portable device with high contrast imaging capability, we designed a quantitative phase microscope using transport of intensity equation method based on a smartphone. The whole system employs an objective and an eyepiece as imaging system and a cost-effective LED as illumination source. A 3-D printed cradle is used to align these components. Images of different focal planes are captured by manual focusing, followed by calculation of sample phase via a self-developed Android application. To validate its accuracy, we first tested the device by measuring a random phase plate with known phases, and then red blood cell smear, Pap smear, broad bean epidermis sections and monocot root were also measured to show its performance. Owing to its advantages as accuracy, high-contrast, cost-effective and portability, the portable smartphone based quantitative phase microscope is a promising tool which can be future adopted in remote healthcare and medical diagnosis.
A Foundation for Enterprise Imaging: HIMSS-SIIM Collaborative White Paper.
Roth, Christopher J; Lannum, Louis M; Persons, Kenneth R
2016-10-01
Care providers today routinely obtain valuable clinical multimedia with mobile devices, scope cameras, ultrasound, and many other modalities at the point of care. Image capture and storage workflows may be heterogeneous across an enterprise, and as a result, they often are not well incorporated in the electronic health record. Enterprise Imaging refers to a set of strategies, initiatives, and workflows implemented across a healthcare enterprise to consistently and optimally capture, index, manage, store, distribute, view, exchange, and analyze all clinical imaging and multimedia content to enhance the electronic health record. This paper is intended to introduce Enterprise Imaging as an important initiative to clinical and informatics leadership, and outline its key elements of governance, strategy, infrastructure, common multimedia content, acquisition workflows, enterprise image viewers, and image exchange services.
Portable emittance measurement device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liakin, D.; Seleznev, D.; Orlov, A.
2010-02-15
In Institute for Theoretical and Experimental Physics (ITEP) the portable emittance measurements device is developed. It provides emittance measurements both with ''pepper-pot'' and ''two slits'' methods. Depending on the method of measurements, either slits or pepper-pot mask with scintillator are mounted on the two activators and are installed in two standard Balzer's cross chamber with CF-100 flanges. To match the angle resolution for measured beam, the length of the stainless steel pipe between two crosses changes is adjusted. The description of the device and results of emittance measurements at the ITEP ion source test bench are presented.
Diffusion of innovations: smartphones and wireless anatomy learning resources.
Trelease, Robert B
2008-01-01
The author has previously reported on principles of diffusion of innovations, the processes by which new technologies become popularly adopted, specifically in relation to anatomy and education. In presentations on adopting handheld computers [personal digital assistants (PDAs)] and personal media players for health sciences education, particular attention has been directed to the anticipated integration of PDA functions into popular cellular telephones. However, limited distribution of early "smartphones" (e.g., Palm Treo and Blackberry) has provided few potential users for anatomical learning resources. In contrast, iPod media players have been self-adopted by millions of students, and "podcasting" has become a popular medium for distributing educational media content. The recently introduced Apple iPhone has combined smartphone and higher resolution media player capabilities. The author successfully tested the iPhone and the "work alike" iPod touch wireless media player with text-based "flashcard" resources, existing PDF educational documents, 3D clinical imaging data, lecture "podcasts," and clinical procedure video. These touch-interfaced, mobile computing devices represent just the first of a new generation providing practical, scalable wireless Web access with enhanced multimedia capabilities. With widespread student self-adoption of such new personal technology, educators can look forward to increasing portability of well-designed, multiplatform "learn anywhere" resources. Copyright 2008 American Association of Anatomists
Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok
2014-01-01
AIM: To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. METHODS: Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. RESULTS: In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. CONCLUSION: The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding. PMID:25009396
ERIC Educational Resources Information Center
Kountz, John
1991-01-01
Description of high density data storage (HDDS) devices focuses on CD-ROMs and explores their impact on libraries, publishing, education, and library communications. Highlights include costs; technical standards; reading devices; authoring systems; robotics; the influence of new technology on the role of libraries; and royalty and copyright issues…
Portable Diagnostics and Rapid Germination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dunn, Zachary Spencer
In the Bioenergy and Defense Department of Sandia National Laboratories, characterization of the BaDx (Bacillus anthracis diagnostic cartridge) was performed and rapid germination chemistry was investigated. BaDx was tested with complex sample matrixes inoculated with Bacillus anthracis, and the trials proved that BaDx will detect Bacillus anthracis in a variety of the medium, such as dirt, serum, blood, milk, and horse fluids. The dimensions of the device were altered to accommodate an E. coli or Listeria lateral flow immunoassay, and using a laser printer, BaDx devices were manufactured to identify E. coli and Listeria. Initial testing with E. coli versionsmore » of BaDx indicate that the device will be viable as a portable diagnostic cartridge. The device would be more effective with faster bacteria germination; hence studies were performed the use of rapid germination chemistry. Trials with calcium dipicolinic acid displayed increased cell germination, as shown by control studies using a microplate reader. Upon lyophilization the rapid germination chemistry failed to change growth patterns, indicating that the calcium dipicolinic acid was not solubilized under the conditions tested. Although incompatible with the portable diagnostic device, the experiments proved that the rapid germination chemistry was effective in increasing cell germination.« less
Note: A portable pulsed neutron source based on the smallest sealed-type plasma focus device.
Niranjan, Ram; Rout, R K; Mishra, Prabhat; Srivastava, Rohit; Rawool, A M; Kaushik, T C; Gupta, Satish C
2011-02-01
Development and operation of a portable and compact pulsed neutron source based on sealed-type plasma focus (PF) device are reported. The unit is the smallest sealed-type neutron producing PF device. The effective volume of the PF unit is 33 cm(3) only. A compact size single capacitor (4 μF) is used as the energy driver. A battery based power supply unit is used for charging the capacitor and triggering the spark gap. The PF unit is operated at 10 kV (200 J) and at a deuterium gas filling pressure of 8 mb. The device is operated over a time span of 200 days and the neutron emissions have been observed for 200 shots without changing the gas in between the shots. The maximum yield of this device is 7.8 × 10(4) neutrons/pulse. Beyond 200 shots the yield is below the threshold (1050 neutrons/pulse) of our (3)He detector. The neutron energy is evaluated using time of flight technique and the value is (2.49 ± 0.27) MeV. The measured neutron pulse width is (24 ± 5) ns. Multishot and long duration operations envisage the potentiality of such portable device for repetitive mode of operation.
Research: Testing of a Novel Portable Body Temperature Conditioner Using a Thermal Manikin.
Heller, Daniel; Heller, Alex; Moujaes, Samir; Williams, Shelley J; Hoffmann, Ryan; Sarkisian, Paul; Khalili, Kaveh; Rockenfeller, Uwe; Browder, Timothy D; Kuhls, Deborah A; Fildes, John J
2016-01-01
A battery-operated active cooling/heating device was developed to maintain thermoregulation of trauma victims in austere environments while awaiting evacuation to a hospital for further treatment. The use of a thermal manikin was adopted for this study in order to simulate load testing and evaluate the performance of this novel portable active cooling/heating device for both continuous (external power source) and battery power. The performance of the portable body temperature conditioner (PBTC) was evaluated through cooling/heating fraction tests to analyze the heat transfer between a thermal manikin and circulating water blanket to show consistent performance while operating under battery power. For the cooling/heating fraction tests, the ambient temperature was set to 15°C ± 1°C (heating) and 30°C ± 1°C (cooling). The PBTC water temperature was set to 37°C for the heating mode tests and 15°C for the cooling mode tests. The results showed consistent performance of the PBTC in terms of cooling/heating capacity while operating under both continuous and battery power. The PBTC functioned as intended and shows promise as a portable warming/cooling device for operation in the field.
Ivanov, Vladimir I; Yu, Paul L; Baras, John S
2010-09-01
Medical information is extremely sensitive in nature - a compromise, such as eavesdropping or tampering by a malicious third party, may result in identity theft, incorrect diagnosis and treatment, and even death. Therefore, it is important to secure the transfer of medical information from the patient to the recording system. We consider a portable, wireless device transferring medical information to a remote server. We decompose this problem into two sub-problems and propose security solutions to each of them: (1) to secure the link between the patient and the portable device, and (2) to secure the link between the portable device and the network. Thus we push the limits of the network security to the edge by authenticating the user using their biometric information; authenticating the device to the network at the physical layer; and strengthening the security of the wireless link with a key exchange mechanism. The proposed authentication methods can be used for recording the readings of medical data in a central database and for accessing medical records in various settings.
Portable telepathology: methods and tools.
Alfaro, Luis; Roca, Ma José
2008-07-15
Telepathology is becoming easier to implement in most pathology departments. In fact e-mail image transmit can be done from almost any pathologist as a simplistic telepathology system. We tried to develop a way to improve capabilities of communication among pathologists with the idea that the system should be affordable for everybody. We took the premise that any pathology department would have microscopes and computers with Internet connection, and selected a few elements to convert them into a telepathology station. Needs were reduced to a camera to collect images, a universal microscope adapter for the camera, a device to connect the camera to the computer, and a software for the remote image transmit. We found out a microscope adapter (MaxView Plus) that allowed us connect almost any domestic digital camera to any microscope. The video out signal from the camera was sent to the computer through an Aver Media USB connector. At last, we selected a group of portable applications that were assembled into a USB memory device. Portable applications are computer programs that can be carried generally on USB flash drives, but also in any other portable device, and used on any (Windows) computer without installation. Besides, when unplugging the device, none of personal data is left behind. We selected open-source applications, and based the pathology image transmission to VLC Media Player due to its functionality as streaming server, portability and ease of use and configuration. Audio transmission was usually done through normal phone lines. We also employed alternative videoconferencing software, SightSpeed for bi-directional image transmission from microscopes, and conventional cameras allowing visual communication and also image transmit from gross pathology specimens. All these elements allowed us to install and use a telepathology system in a few minutes, fully prepared for real time image broadcast.
Portable telepathology: methods and tools
Alfaro, Luis; Roca, Ma José
2008-01-01
Telepathology is becoming easier to implement in most pathology departments. In fact e-mail image transmit can be done from almost any pathologist as a simplistic telepathology system. We tried to develop a way to improve capabilities of communication among pathologists with the idea that the system should be affordable for everybody. We took the premise that any pathology department would have microscopes and computers with Internet connection, and selected a few elements to convert them into a telepathology station. Needs were reduced to a camera to collect images, a universal microscope adapter for the camera, a device to connect the camera to the computer, and a software for the remote image transmit. We found out a microscope adapter (MaxView Plus) that allowed us connect almost any domestic digital camera to any microscope. The video out signal from the camera was sent to the computer through an Aver Media USB connector. At last, we selected a group of portable applications that were assembled into a USB memory device. Portable applications are computer programs that can be carried generally on USB flash drives, but also in any other portable device, and used on any (Windows) computer without installation. Besides when unplugging the device, none of personal data is left behind. We selected open-source applications, and based the pathology image transmission to VLC Media Player due to its functionality as streaming server, portability and ease of use and configuration. Audio transmission was usually done through normal phone lines. We also employed alternative videoconferencing software, SightSpeed for bi-directional image transmission from microscopes, and conventional cameras allowing visual communication and also image transmit from gross pathology specimens. All these elements allowed us to install and use a telepathology system in a few minutes, fully prepared for real time image broadcast. PMID:18673507
Development of an ultra-portable echo device connected to USB port.
Saijo, Yoshifumi; Nitta, Shin-ichi; Kobayashi, Kazuto; Arai, Hitoshi; Nemoto, Yukiko
2004-04-01
In practical cardiology, a stethoscope based auscultation has been used to reveal the patient's clinical status. Recently, several hand-held echo devices are going on market and they are expected to play a role as "visible" auscultation instead of stethoscope. We have developed a portable and inexpensive echo device which can be used for screening of cardiac function. Two single element transducers were attached 180 degrees apart to a rotor with 14-mm diameter. The mechanical scanner, integrated circuits for transmitting and receiving ultrasonic signals and an A/D converter were encapsulated in a 150 x 40 mm probe weighing 200 g. The scan was started and the image was displayed on a Windows based personal computer (PC) as soon as the probe was connected to USB 2.0 port of the PC. The central frequency was available between 2.5 and 7.5 MHz, the image depth was 15 cm and the frame rate was 30/s. The estimated price of this ultra-portable ultrasound is about 3000 US dollars with software. For 69 cardiac patients with informed consent, image quality was compared with those obtained with basic range diagnostic echo machines. Left ventricular ejection fraction (EF) derived from normal M-mode image of standard machines (EFm) were compared with visual EF of the ultra-portable ultrasound device (EFv). The image quality was comparable to the basic range diagnostic echo machines although short axis view of aortic root was not clearly visualized because the probe was too large for intercostal approach. EFv agreed well with EFm. The ultra-portable ultrasound may provide useful information on screening and health care.
Portable outgas detection apparatus
Haney, Steven Julian; Malinowski, Michael E.
2004-05-11
A portable device for detecting surface outgas contaminants of an article includes: (i) a portable housing that has a chamber which is in communication with a port that is adapted to be sealably attached to a surface of the article; (ii) a mass spectrometer that is coupled to the chamber for analyzing gaseous materials in the chamber; and (iii) means for generating a vacuum within the chamber thereby drawing outgas contaminants from the surface of the article into the chamber for analysis by the mass spectrometer. By performing a mass spectrometric analysis of the surface of interest and comparing the data with mass spectrometric data ascertained with the device from a clean surface, the type and amount of outgas contaminants, if any, can be determined.
Forensic Analysis of the Sony Playstation Portable
NASA Astrophysics Data System (ADS)
Conrad, Scott; Rodriguez, Carlos; Marberry, Chris; Craiger, Philip
The Sony PlayStation Portable (PSP) is a popular portable gaming device with features such as wireless Internet access and image, music and movie playback. As with most systems built around a processor and storage, the PSP can be used for purposes other than it was originally intended - legal as well as illegal. This paper discusses the features of the PSP browser and suggests best practices for extracting digital evidence.
NASA Astrophysics Data System (ADS)
Hermoso, J. L. Navarro; Espinosa-Rueda, Guillermo; Martinez, Noelia; Heras, Carlos; Osta, Marta
2016-05-01
The performance of parabolic trough (PT) receiver tubes (RT) has a direct impact on Solar Thermal Energy (STE) plant production. As a result, one major need of operation and maintenance (O&M) in STE plants is to monitor the state of the receiver tube as a key element in the solar field. However the lack of specific devices so far has limited the proper evaluation of operating receiver tubés thermal performance. As a consequence non-accurate approximations have been accepted until now using infrared thermal images of the glass outer tube. In order to fulfill this need, Abengoa has developed a unique portable device for evaluating the thermal performance and vacuum state of parabolic trough receiver tubes placed in the field. The novel device described in this paper, simultaneously provides the temperature of both the inner steel tube and the outer glass tube enabling a check on manufacturers specifications. The on-field evaluation of any receiver tube at any operating temperature has become possible thanks to this new measuring device. The features and usability of this new measurement system as a workable portable device in operating solar fields provide a very useful tool for all companies in the sector contributing to technology progress. The originality of the device, patent pending P201431969, is not limited to the CSP sector, also having scientific significance in the general measuring instruments field. This paper presents the work carried out to develop and validate the device, also detailing its functioning properties and including the excellent results obtained in the laboratory to determine its accuracy and standard deviation. This information was validated with data collected by O&M teams using this instrument in a commercial CSP plant. The relevance of the device has been evidenced by evaluating a wide sample of RT and the results are discussed in this paper. Finally, all the on field collected data is used to demonstrate the high impact that using this unique portable device will have on a parabolic trough solar power plant.
NASA Astrophysics Data System (ADS)
Knackmuß, Jenny; Creutzburg, Reiner
2014-02-01
The aim of this paper is to describe the benefit and support of virtual tutorials, Wikipedia books and multimedia-based teaching in a course on Algorithms and Data Structures. We describe our work and experiences gained from using virtual tutorials held in Netucate iLinc sessions and the use of various multimedia and animation elements for the support of deeper understanding of the ordinary lectures held in the standard classroom on Algorithms and Data Structures for undergraduate computer sciences students. We will describe the benefits, form, style and contents of those virtual tutorials. Furthermore, we mention the advantage of Wikipedia books to support the blended learning process using modern mobile devices. Finally, we give some first statistical measures of improved student's scores after introducing this new form of teaching support.
Low-power laser treatment of musculoskeletal disorders and body measurements of the equine athlete
NASA Astrophysics Data System (ADS)
Antikas, Theo G.
1990-09-01
This field report presents and analyzes results on 1 cases of rnusculoskeletal disorders of equine athletes treated either with a Soft Laser 632 device (Worldwide Lasers International Geneva) or with an Omega Biotherapy infrared multiprobe multiwavelength device (Omega Labs London). It proposes a codification of low power laser forms of treatment onthefield and suggests modalities of such treatment(s). The therapeutic effects of low power laser beams as well as their postulated modes of action are discussed. Further a new technique utilizing a low power laser device (Technosynthese AG Zurich) for the accurate rnesurement of the height of ponies and horses is described. After testing in over 500 equines the apparatus and the technique were found accurate with an error factor not exceeding 1. 2 mm (1/20 inch) whereas the ancient ''standard stick'' method was found to produce a constant significant error in all animals measured. MATERIALS AND METHODS Soft Laser 632R device: Portable 25 mW heliumneon laser device emitting a visible red band of 632. 8 nm either through a ''window'' or through an optic fiber probe. Omega Biotherapy device: Portable 50 mW infrared laser device with two probes and a multiprobe emitting four wavelength laser bands. Pony_MetreR: Portable heliumneon device with two incorporated nivels and sliding through a rotating ''head'' placed at the top of a tripod that can move on either the vertical (x) or horizontal y) axis. RESULTS
NASA Astrophysics Data System (ADS)
Castel, J. G.; Husarek, V.
1987-06-01
The usefulness of a portable microprocessor-controlled ultrasound device for the periodic assessment of aircraft parts made of composite materials is shown. The performance of the device is demonstrated with the examples of a metallic honeycomb with a carbon-fiber skin, a phenolic honeycomb with a carbon skin, and a phenolic honeycomb with a Kevlar skin. Also considered are assessments of homogeneous carbon-fiber parts, including the study of artificial defects consisting of 1-2 mm diameter holes, and the assessment of the behavior of a carbon-titanium interface with separated zones. Advantages of the device include ease of adjustment, automated evaluation of the depth of defects, and the nearly-absolute reproducibility of adjustments.
A portable wheel tester for tyre-road friction and rolling resistance determination
NASA Astrophysics Data System (ADS)
Pytka, J.; Budzyński, P.; Tarkowski, P.; Piaskowski, M.
2016-09-01
The paper describes theory of operation, design and construction as well as results from primarily experiments with a portable wheel tester that has been developed by the authors as a device for on-site determination of tyre-road braking/driving friction and rolling resistance. The paper includes schematics, drawings, descriptions as well as graphical results form early tests with the presented device. It is expected that the tester can be useful in road accident reconstruction applications as well as in vehicle dynamics research.
NASA Astrophysics Data System (ADS)
Manurung, Sondang; Demonta Pangabean, Deo
2017-05-01
The main purpose of this study is to produce needs analysis, literature review, and learning tools in the study of developmental of interactive multimedia based physic learning charged in problem solving to improve thinking ability of physic prospective student. The first-year result of the study is: result of the draft based on a needs analysis of the facts on the ground, the conditions of existing learning and literature studies. Following the design of devices and instruments performed as well the development of media. Result of the second study is physics learning device -based interactive multimedia charged problem solving in the form of textbooks and scientific publications. Previous learning models tested in a limited sample, then in the evaluation and repair. Besides, the product of research has an economic value on the grounds: (1) a virtual laboratory to offer this research provides a solution purchases physics laboratory equipment is expensive; (2) address the shortage of teachers of physics in remote areas as a learning tool can be accessed offline and online; (3). reducing material or consumables as tutorials can be done online; Targeted research is the first year: i.e story board learning physics that have been scanned in a web form CD (compact disk) and the interactive multimedia of gas Kinetic Theory concept. This draft is based on a needs analysis of the facts on the ground, the existing learning conditions, and literature studies. Previous learning models tested in a limited sample, then in the evaluation and repair.
Intelligent MEMS spectral sensor for NIR applications (Conference Presentation)
NASA Astrophysics Data System (ADS)
Kantojärvi, Uula; Antila, Jarkko E.; Mäkynen, Jussi; Suhonen, Janne
2017-05-01
Near Infrared (NIR) spectrometers have been widely used in many material inspection applications, but mainly in central laboratories. The role of miniaturization, robustness of spectrometer and portability are really crucial when field inspection tools should be developed. We present an advanced spectral sensor based on a tunable Microelectromechanical (MEMS) Fabry-Perot Interferometer which will meet these requirements. We describe the wireless device design, operation principle and easy-to-use algorithms to adapt the sensor to number of applications. Multiple devices can be operated simultaneously and seamlessly through cloud connectivity. We also present some practical NIR applications carried out with truly portable NIR device.
Lucani, Daniel; Cataldo, Giancarlos; Cruz, Julio; Villegas, Guillermo; Wong, Sara
2006-01-01
A prototype of a portable ECG-monitoring device has been developed for clinical and non-clinical environments as part of a telemedicine system to provide remote and continuous surveillance of patients. The device can acquire, store and/or transmit ECG signals to computer-based platforms or specially configured access points (AP) with Intranet/Internet capabilities in order to reach remote monitoring stations. Acquired data can be stored in a flash memory card in FAT16 format for later recovery, or transmitted via Bluetooth or USB to a local station or AP. This data acquisition module (DAM) operates in two modes: Holter and on-line transmission.
Design of Efficient Mirror Adder in Quantum- Dot Cellular Automata
NASA Astrophysics Data System (ADS)
Mishra, Prashant Kumar; Chattopadhyay, Manju K.
2018-03-01
Lower power consumption is an essential demand for portable multimedia system using digital signal processing algorithms and architectures. Quantum dot cellular automata (QCA) is a rising nano technology for the development of high performance ultra-dense low power digital circuits. QCA based several efficient binary and decimal arithmetic circuits are implemented, however important improvements are still possible. This paper demonstrate Mirror Adder circuit design in QCA. We present comparative study of mirror adder cells designed using conventional CMOS technique and mirror adder cells designed using quantum-dot cellular automata. QCA based mirror adders are better in terms of area by order of three.
30 CFR 77.903 - Disconnecting devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Disconnecting devices. 77.903 Section 77.903... Medium-Voltage Alternating Current Circuits § 77.903 Disconnecting devices. Disconnecting devices shall be installed in circuits supplying power to portable or mobile equipment and shall provide visual...
Geckle, Joan
2016-01-01
The purpose of this literature review is to summarize studies of the use of multimedia technology by adolescents to engage in their healthcare promotion and disease prevention. A systematic literature review of relevant peer-reviewed research published between 2009 and 2014 was performed. The 16 articles reviewed were a combination of quantitative and mixed-method methodology based on the efficacy of multimedia, mobile technology, Short Messaging Services (SMS) texting, and social networking (e.g., Facebook®), to engage adolescents ages 10 to 20 years in health promotion and disease prevention. Although adolescents have high attrition rates in the studies, they demonstrated advantages in using SMS texting features and social networking, especially the chat function, in relation to health promotion and disease prevention. Some small gains were noticed in health promotion and disease prevention in the majority of the studies, though some were not significant due to attrition. Additional research, especially nursing research, is necessary. Mobile and multimedia technology allows for a promising correlation between adolescents and increased healthcare knowledge, health promotion, and disease prevention.
Portable wireless neurofeedback system of EEG alpha rhythm enhances memory.
Wei, Ting-Ying; Chang, Da-Wei; Liu, You-De; Liu, Chen-Wei; Young, Chung-Ping; Liang, Sheng-Fu; Shaw, Fu-Zen
2017-11-13
Effect of neurofeedback training (NFT) on enhancement of cognitive function or amelioration of clinical symptoms is inconclusive. The trainability of brain rhythm using a neurofeedback system is uncertainty because various experimental designs are used in previous studies. The current study aimed to develop a portable wireless NFT system for alpha rhythm and to validate effect of the NFT system on memory with a sham-controlled group. The proposed system contained an EEG signal analysis device and a smartphone with wireless Bluetooth low-energy technology. Instantaneous 1-s EEG power and contiguous 5-min EEG power throughout the training were developed as feedback information. The training performance and its progression were kept to boost usability of our device. Participants were blinded and randomly assigned into either the control group receiving random 4-Hz power or Alpha group receiving 8-12-Hz power. Working memory and episodic memory were assessed by the backward digital span task and word-pair task, respectively. The portable neurofeedback system had advantages of a tiny size and long-term recording and demonstrated trainability of alpha rhythm in terms of significant increase of power and duration of 8-12 Hz. Moreover, accuracies of the backward digital span task and word-pair task showed significant enhancement in the Alpha group after training compared to the control group. Our tiny portable device demonstrated success trainability of alpha rhythm and enhanced two kinds of memories. The present study suggest that the portable neurofeedback system provides an alternative intervention for memory enhancement.
Stark, Peter C [Los Alamos, NM; Zurek, Eduardo [Barranquilla, CO; Wheat, Jeffrey V [Fort Walton Beach, FL; Dunbar, John M [Santa Fe, NM; Olivares, Jose A [Los Alamos, NM; Garcia-Rubio, Luis H [Temple Terrace, FL; Ward, Michael D [Los Alamos, NM
2011-07-26
There is provided a method and device for remote sampling, preparation and optical interrogation of a sample using light scattering and light absorption methods. The portable device is a filtration-based device that removes interfering background particle material from the sample matrix by segregating or filtering the chosen analyte from the sample solution or matrix while allowing the interfering background particles to be pumped out of the device. The segregated analyte is then suspended in a diluent for analysis. The device is capable of calculating an initial concentration of the analyte, as well as diluting the analyte such that reliable optical measurements can be made. Suitable analytes include cells, microorganisms, bioparticles, pathogens and diseases. Sample matrixes include biological fluids such as blood and urine, as well as environmental samples including waste water.
Yoshida, Taiki; Otaka, Yohei; Osu, Rieko; Kita, Kahori; Sakata, Sachiko; Kondo, Kunitsugu
2017-05-01
Older and/or cognitively impaired patients require verbal guidance to prevent accidents during wheelchair operation, thus increasing the burden on caregivers. This study aimed to develop a new portable voice guidance device for manual wheelchairs and examine its clinical usefulness. We developed a portable voice guidance device to monitor the statuses of wheelchair brakes and footrests and automatically provide voice guidance for operation. The device comprises a microcomputer, four magnets and magnetic sensors, speaker and battery. Device operation was assessed during the transfer from a wheelchair to bed six times per day over three days for a total of 90 transfers in five stroke patients (mean age: 79.6 years) who required verbal guidance to direct wheelchair operation. Device usability was also assessed using a questionnaire. The device performed perfectly during all attempted transfers (100%). To ensure safety, the assessor needed to add verbal guidance during 33 of 90 attempted transfers (36.6%). Overall, the device usability was favourable. However, some assessors were unsatisfied with the volume of the device voice, guidance timing and burden reduction. Our device could facilitate wheelchair operation and might potentially be used to reduce fall risk in stroke patients and the burden on caregivers. Implications for Rehabilitation The acquisition of transfer independence is an important step in the rehabilitation of patients with mobility issues. Many patients require supervision and guidance regarding the operation of brakes and footrests on manual wheelchairs. This newly developed voice guidance device for manual wheelchair transfers worked well in patients with hemiplegia and might be helpful to reduce the fall risks and the burden of care.
Bulanek, Boris; Hulka, Jiri; Jilek, Karel; Stekl, Ivan
2015-06-01
In this article, a portable device was presented for continual measuring of equilibrium equivalent concentration (EEC) of (222)Rn based on the Timepix detector with 300-µm-thick active layer. In order to have a portable device, a filtration head was developed for collecting short-lived radon progenies attached on aerosols. The short-lived progenies are estimated from analysing alphas from decay of (218,214)Po from Millipore filter after termination of filtration. Comparison with beta measurement was done as well. The dependence of EEC on an air flow and filtration time was studied. The low-level detection limit for EEC was estimated from the last 10 min of 3-h decay measurement and was found in the range of 40-70 Bq m(-3). EEC was measured in National Radiation Protection Institute radon chamber, and results were compared with the commercial detector Fritra4. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Design of a portable imager for near-infrared visualization of cutaneous wounds
Peng, Zhaoqiang; Zhou, Jun; Dacy, Ashley; Zhao, Deyin; Kearney, Vasant; Zhou, Weidong; Tang, Liping; Hu, Wenjing
2017-01-01
Abstract. A portable imager developed for real-time imaging of cutaneous wounds in research settings is described. The imager consists of a high-resolution near-infrared CCD camera capable of detecting both bioluminescence and fluorescence illuminated by an LED ring with a rotatable filter wheel. All external components are integrated into a compact camera attachment. The device is demonstrated to have competitive performance with a commercial animal imaging enclosure box setup in beam uniformity and sensitivity. Specifically, the device was used to visualize the bioluminescence associated with increased reactive oxygen species activity during the wound healing process in a cutaneous wound inflammation model. In addition, this device was employed to observe the fluorescence associated with the activity of matrix metalloproteinases in a mouse lipopolysaccharide-induced infection model. Our results support the use of the portable imager design as a noninvasive and real-time imaging tool to assess the extent of wound inflammation and infection. PMID:28114448
29 CFR 1910.26 - Portable metal ladders.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Walking-Working Surfaces § 1910.26 Portable metal ladders. (a... material for the safety of the user. (viii) A metal spreader or locking device of sufficient size and...
Real-time 3D adaptive filtering for portable imaging systems
NASA Astrophysics Data System (ADS)
Bockenbach, Olivier; Ali, Murtaza; Wainwright, Ian; Nadeski, Mark
2015-03-01
Portable imaging devices have proven valuable for emergency medical services both in the field and hospital environments and are becoming more prevalent in clinical settings where the use of larger imaging machines is impractical. 3D adaptive filtering is one of the most advanced techniques aimed at noise reduction and feature enhancement, but is computationally very demanding and hence often not able to run with sufficient performance on a portable platform. In recent years, advanced multicore DSPs have been introduced that attain high processing performance while maintaining low levels of power dissipation. These processors enable the implementation of complex algorithms like 3D adaptive filtering, improving the image quality of portable medical imaging devices. In this study, the performance of a 3D adaptive filtering algorithm on a digital signal processor (DSP) is investigated. The performance is assessed by filtering a volume of size 512x256x128 voxels sampled at a pace of 10 MVoxels/sec.
Copy Hiding Application Interface
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, Holger; Poliakoff, David; Robinson, Peter
2016-10-06
CHAI is a light-weight framework which abstracts the automated movement of data (e.g. to/from Host/Device) via RAJA like performance portability programming model constructs. It can be viewed as a utility framework and an adjunct to FAJA (A Performance Portability Framework). Performance Portability is a technique that abstracts the complexities of modern Heterogeneous Architectures while allowing the original program to undergo incremental minimally invasive code changes in order to adapt to the newer architectures.
Macintosh, David L; Myatt, Theodore A; Ludwig, Jerry F; Baker, Brian J; Suh, Helen H; Spengler, John D
2008-11-01
A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the absence of operating a central fan or an indoor air cleaner. Removal rates of 0.3- to 0.5-microm particles ranged from 1.5 hr(-1) during operation of an in-duct, 5-in. pleated media filter to 7.2 hr(-1) for an in-duct electrostatic air cleaner in comparison to a baseline rate of 0 hr(-1) when the air handler was operating without a filter. Removal rates for total particulate matter less than 2.5 microm in aerodynamic diameter (PM2.5) mass concentrations were 0.5 hr(-1) under baseline conditions, 0.5 hr(-1) during operation of three portable ionic air cleaners, 1 hr(-1) for an in-duct 1-in. media filter, 2.4 hr(-1) for a single high-efficiency particle arrestance (HEPA) portable air cleaner, 4.6 hr(-1) for an in-duct 5-in. media filter, 4.7 hr(-1) during operation of five portable HEPA filters, 6.1 hr(-1) for a conventional in-duct electronic air cleaner, and 7.5 hr(-1) for a high efficiency in-duct electrostatic air cleaner. Corresponding whole house clean air delivery rates for PM2.5 attributable to the air cleaner independent of losses within the central ventilation system ranged from 2 m3/min for the conventional media filter to 32 m3/min for the high efficiency in-duct electrostatic device. Except for the portable ionic air cleaner, the devices considered here increased particle removal indoors over baseline deposition rates.
Portable device for the detection of colorimetric assays
Nowak, E.; Kawchuk, J.; Hoorfar, M.; Najjaran, H.
2017-01-01
In this work, a low-cost, portable device is developed to detect colorimetric assays for in-field and point-of-care (POC) analysis. The device can rapidly detect both pH values and nitrite concentrations of five different samples, simultaneously. After mixing samples with specific reagents, a high-resolution digital camera collects a picture of the sample, and a single-board computer processes the image in real time to identify the hue–saturation–value coordinates of the image. An internal light source reduces the effect of any ambient light so the device can accurately determine the corresponding pH values or nitrite concentrations. The device was purposefully designed to be low-cost, yet versatile, and the accuracy of the results have been compared to those from a conventional method. The results obtained for pH values have a mean standard deviation of 0.03 and a correlation coefficient R2 of 0.998. The detection of nitrites is between concentrations of 0.4–1.6 mg l−1, with a low detection limit of 0.2 mg l−1, and has a mean standard deviation of 0.073 and an R2 value of 0.999. The results represent great potential of the proposed portable device as an excellent analytical tool for POC colorimetric analysis and offer broad accessibility in resource-limited settings. PMID:29291093
NASA Astrophysics Data System (ADS)
Pla, D.; Sánchez-González, A.; Garbayo, I.; Salleras, M.; Morata, A.; Tarancón, A.
2015-10-01
The inherent limited capacity of current battery technology is not sufficient for covering the increasing power requirements of widely extended portable devices. Among other promising alternatives, recent advances in the field of micro-Solid Oxide Fuel Cells (μ-SOFCs) converted this disruptive technology into a serious candidate to power next generations of portable devices. However, the implementation of single cells in real devices, i.e. μ-SOFC stacks coupled to the required balance-of-plant elements like fuel reformers or post combustors, still remains unexplored. This work aims addressing this system-level research by proposing a new compact design of a vertically stacked device fuelled with ethanol. The feasibility and design optimization for achieving a thermally self-sustained regime and a rapid and low-power consuming start-up is studied by finite volume analysis. An optimal thermal insulation strategy is defined to maintain the steady-state operation temperature of the μ-SOFC at 973 K and an external temperature lower than 323 K. A hybrid start-up procedure, based on heaters embedded in the μ-SOFCs and heat released by chemical reactions in the post-combustion unit, is analyzed allowing start-up times below 1 min and energy consumption under 500 J. These results clearly demonstrate the feasibility of high temperature μ-SOFC power systems fuelled with hydrocarbons for portable applications, therefore, anticipating a new family of mobile and uninterrupted power generators.
Fringe projection profilometry with portable consumer devices
NASA Astrophysics Data System (ADS)
Liu, Danji; Pan, Zhipeng; Wu, Yuxiang; Yue, Huimin
2018-01-01
A fringe projection profilometry (FPP) using portable consumer devices is attractive because it can realize optical three dimensional (3D) measurement for ordinary consumers in their daily lives. We demonstrate a FPP using a camera in a smart mobile phone and a digital consumer mini projector. In our experiment of testing the smart phone (iphone7) camera performance, the rare-facing camera in the iphone7 causes the FPP to have a fringe contrast ratio of 0.546, nonlinear carrier phase aberration value of 0.6 rad, and nonlinear phase error of 0.08 rad and RMS random phase error of 0.033 rad. In contrast, the FPP using the industrial camera has a fringe contrast ratio of 0.715, nonlinear carrier phase aberration value of 0.5 rad, nonlinear phase error of 0.05 rad and RMS random phase error of 0.011 rad. Good performance is achieved by using the FPP composed of an iphone7 and a mini projector. 3D information of a facemask with a size for an adult is also measured by using the FPP that uses portable consumer devices. After the system calibration, the 3D absolute information of the facemask is obtained. The measured results are in good agreement with the ones that are carried out in a traditional way. Our results show that it is possible to use portable consumer devices to construct a good FPP, which is useful for ordinary people to get 3D information in their daily lives.
Pulse-driven micro gas sensor fitted with clustered Pd/SnO2 nanoparticles.
Suematsu, Koichi; Shin, Yuka; Ma, Nan; Oyama, Tokiharu; Sasaki, Miyuki; Yuasa, Masayoshi; Kida, Tetsuya; Shimanoe, Kengo
2015-08-18
Real-time monitoring of specific gas concentrations with a compact and portable gas sensing device is required to sense potential health risk and danger from toxic gases. For such purposes, we developed an ultrasmall gas sensor device, where a micro sensing film was deposited on a micro heater integrated with electrodes fabricated by the microelectromechanical system (MEMS) technology. The developed device was operated in a pulse-heating mode to significantly reduce the heater power consumption and make the device battery-driven and portable. Using clustered Pd/SnO2 nanoparticles, we succeeded in introducing mesopores ranging from 10 to 30 nm in the micro gas sensing film (area: ϕ 150 μm) to detect large volatile organic compounds (VOCs). The micro sensor showed quick, stable, and high sensor responses to toluene at ppm (parts per million) concentrations at 300 °C even by operating the micro heater in a pulse-heating mode where switch-on and -off cycles were repeated at one-second intervals. The high performance of the micro sensor should result from the creation of efficient diffusion paths decorated with Pd sensitizers by using the clustered Pd/SnO2 nanoparticles. Hence we demonstrate that our pulse-driven micro sensor using nanostructured oxide materials holds promise as a battery-operable, portable gas sensing device.
High performance 3D adaptive filtering for DSP based portable medical imaging systems
NASA Astrophysics Data System (ADS)
Bockenbach, Olivier; Ali, Murtaza; Wainwright, Ian; Nadeski, Mark
2015-03-01
Portable medical imaging devices have proven valuable for emergency medical services both in the field and hospital environments and are becoming more prevalent in clinical settings where the use of larger imaging machines is impractical. Despite their constraints on power, size and cost, portable imaging devices must still deliver high quality images. 3D adaptive filtering is one of the most advanced techniques aimed at noise reduction and feature enhancement, but is computationally very demanding and hence often cannot be run with sufficient performance on a portable platform. In recent years, advanced multicore digital signal processors (DSP) have been developed that attain high processing performance while maintaining low levels of power dissipation. These processors enable the implementation of complex algorithms on a portable platform. In this study, the performance of a 3D adaptive filtering algorithm on a DSP is investigated. The performance is assessed by filtering a volume of size 512x256x128 voxels sampled at a pace of 10 MVoxels/sec with an Ultrasound 3D probe. Relative performance and power is addressed between a reference PC (Quad Core CPU) and a TMS320C6678 DSP from Texas Instruments.
A compact and portable optofluidic device for detection of liquid properties and label-free sensing
NASA Astrophysics Data System (ADS)
Lahoz, F.; Martín, I. R.; Walo, D.; Gil-Rostra, J.; Yubero, F.; Gonzalez-Elipe, A. R.
2017-06-01
Optofluidic lasers have been widely investigated over the last few years mainly because they can be easily integrated in sensor devices. However, high power pulse lasers are required as excitation sources, which, in practice, limit the portability of the system. Trying to overcome some of these limitations, in this paper we propose the combined use of a small CW laser with a Fabry-Perot optofluidic planar microcavity showing high sensitivity and versatility for detection of liquid properties and label-free sensing. Firstly, a fluorescein solution in ethanol is used to demonstrate the high performances of the FP microcavity as a temperature sensor both in the laser (high pump power above laser threshold) and in the fluorescence (low pump power) regimes. A shift in the wavelength of the resonant cavity modes is used to detect changes in the temperature and our results show that high sensitivities could be already obtained using cheap and portable CW diode lasers. In the second part of the paper, the demonstration of this portable device for label-free sensing is illustrated under low CW pumping. The wavelength positions of the optofluidic resonant modes are used to detect glucose concentrations in water solutions using a protein labelled with a fluorescent dye as the active medium.
Micro solid oxide fuel cells: a new generation of micro-power sources for portable applications
NASA Astrophysics Data System (ADS)
Chiabrera, Francesco; Garbayo, Iñigo; Alayo, Nerea; Tarancón, Albert
2017-06-01
Portable electronic devices are already an indispensable part of our daily life; and their increasing number and demand for higher performance is becoming a challenge for the research community. In particular, a major concern is the way to efficiently power these energy-demanding devices, assuring long grid independency with high efficiency, sustainability and cheap production. In this context, technologies beyond Li-ion are receiving increasing attention, among which the development of micro solid oxide fuel cells (μSOFC) stands out. In particular, μSOFC provides a high energy density, high efficiency and opens the possibility to the use of different fuels, such as hydrocarbons. Yet, its high operating temperature has typically hindered its application as miniaturized portable device. Recent advances have however set a completely new range of lower operating temperatures, i.e. 350-450°C, as compared to the typical <900°C needed for classical bulk SOFC systems. In this work, a comprehensive review of the status of the technology is presented. The main achievements, as well as the most important challenges still pending are discussed, regarding (i.) the cell design and microfabrication, and (ii.) the integration of functional electrolyte and electrode materials. To conclude, the different strategies foreseen for a wide deployment of the technology as new portable power source are underlined.
Predicting aged pork quality using a portable raman device
USDA-ARS?s Scientific Manuscript database
Objectives: A need exists for a better on-line evaluation method for pork quality. Raman spectroscopy evaluates structure and composition of food samples, with advantage of being portable, non-invasive and insensitive to water. The objectives of this study were to evaluate the correlation between Ra...
42 CFR 84.70 - Self-contained breathing apparatus; description.
Code of Federal Regulations, 2013 CFR
2013-10-01
... OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self..., including all completely assembled, portable, self-contained devices designed for use as respiratory...
42 CFR 84.70 - Self-contained breathing apparatus; description.
Code of Federal Regulations, 2014 CFR
2014-10-01
... OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self..., including all completely assembled, portable, self-contained devices designed for use as respiratory...
42 CFR 84.70 - Self-contained breathing apparatus; description.
Code of Federal Regulations, 2012 CFR
2012-10-01
... OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self..., including all completely assembled, portable, self-contained devices designed for use as respiratory...
Students' Beliefs about Mobile Devices vs. Desktop Computers in South Korea and the United States
ERIC Educational Resources Information Center
Sung, Eunmo; Mayer, Richard E.
2012-01-01
College students in the United States and in South Korea completed a 28-item multidimensional scaling (MDS) questionnaire in which they rated the similarity of 28 pairs of multimedia learning materials on a 10-point scale (e.g., narrated animation on a mobile device Vs. movie clip on a desktop computer) and a 56-item semantic differential…
A Portable, Shock-Proof, Surface-Heated Droplet PCR System for Escherichia coli Detection
Angus, Scott V.; Cho, Soohee; Harshman, Dustin K.; Song, Jae-Young; Yoon, Jeong-Yeol
2015-01-01
A novel polymerase chain reaction (PCR) device was developed that uses wire-guided droplet manipulation (WDM) to guide a droplet over three different heating chambers. After PCR amplification, end-point detection is achieved using a smartphone-based fluorescence microscope. The device was tested for identification of the 16S rRNA gene V3 hypervariable region from Escherichia coli genomic DNA. The lower limit of detection was 103 genome copies per sample. The device is portable with smartphone-based end-point detection and provides the assay results quickly (15 min for a 30-cycle amplification) and accurately. The system is also shock and vibration resistant, due to the multiple points of contact between the droplet and the thermocouple and the Teflon film on the heater surfaces. The thermocouple also provides realtime droplet temperature feedback to ensure it reaches the set temperature before moving to the next chamber/step in PCR. The device is equipped to use either silicone oil or coconut oil. Coconut oil provides additional portability and ease of transportation by eliminating spilling because its high melting temperature means it is solid at room temperature. PMID:26164008
Pirsa, Sajad
2017-04-01
A portable chromatography device and a method were developed to analyze a gas mixture. The device comprises a chromatographic column for separating components of a sample of the gas mixture. It has an air pump coupled to the inlet of a chromatographic column for pumping air and an injector coupled to the inlet of chromatographic column for feeding the sample using the air as a carrier gas. A detector is arranged downstream from and coupled to the outlet of the chromatographic column. The detector is a nanostructure semiconductive microfiber. The device further comprises an evaluation unit arranged and configured to evaluate each detected component to determine the concentration. The designed portable system was used for simultaneous detection of amines. The possibility of applying dispersive liquid-liquid microextraction for the determination of analytes in trace levels is demonstrated. The reproducibility of this method is acceptable, and good standard deviations were obtained. The relative standard deviation value is less than 6% for all analytes. Finally, the method was successfully applied to the extraction and determination of analytes in water samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Utilisation of Wearable Computing for Space Programmes Test Activities Optimasation
NASA Astrophysics Data System (ADS)
Basso, V.; Lazzari, D.; Alemanni, M.
2004-08-01
New technologies are assuming a relevant importance in the Space business domain also in the Assembly Integration and Test (AIT) activities allowing process optimization and capability that were unthinkable only few years ago. This paper has the aim to describe Alenia Spazio (ALS) gained experience on the remote interaction techniques as a results of collaborations established both on European Communities (EC) initiatives, with Alenia Aeronautica (ALA) and Politecnico of Torino (POLITO). The H/W and S/W components performances increase and costs reduction due to the home computing massive utilization (especially demanded by the games business) together with the network technology possibility (offered by the web as well as the hi-speed links and the wireless communications) allow today to re-think the traditional AIT process activities in the light of the multimedia data exchange: graphical, voice video and by sure more in the future. Aerospace business confirm its innovation vocation which in the year '80 represents the cradle of the CAD systems and today is oriented to the 3D data visualization/ interaction technologies and remote visualisation/ interaction in collaborative way on a much more user friendly bases (i.e. not for specialists). Fig. 1 collects AIT extended scenario studied and adopted by ALS in these years. ALS experimented two possibilities of remote visualization/interaction: Portable [e.g. Fig.2 Personal Digital Assistant (PDA), Wearable] and walls (e.g.VR-Lab) screens as both 2D/3D visualisation and interaction devices which could support many types of traditional (mainly based on EGSE and PDM/CAD utilisation/reports) company internal AIT applications: 1. design review support 2. facility management 3. storage management 4. personnel training 5. integration sequences definition 6. assembly and test operations follow up 7. documentation review and external access to AIT activities for remote operations (e.g. tele-testing) EGSE Portable Clean room Walls PDM/CAD Tele-operations Product Control room External World
Ayaki, Masahiko; Hattori, Atsuhiko; Maruyama, Yusuke; Nakano, Masaki; Yoshimura, Michitaka; Kitazawa, Momoko; Negishi, Kazuno; Tsubota, Kazuo
2016-01-01
We investigated sleep quality and melatonin in 12 adults who wore blue-light shield or control eyewear 2 hours before sleep while using a self-luminous portable device, and assessed visual quality for the two eyewear types. Overnight melatonin secretion was significantly higher after using the blue-light shield (P < 0.05) than with the control eyewear. Sleep efficacy and sleep latency were significantly superior for wearers of the blue-light shield (P < 0.05 for both), and this group reported greater sleepiness during portable device use compared to those using the control eyewear. Participants rated the blue-light shield as providing acceptable visual quality.
NASA Astrophysics Data System (ADS)
Flexman, M. L.; Kim, H. K.; Stoll, R.; Khalil, M. A.; Fong, C. J.; Hielscher, A. H.
2012-03-01
We present a low-cost, portable, wireless diffuse optical imaging device. The handheld device is fast, portable, and can be applied to a wide range of both static and dynamic imaging applications including breast cancer, functional brain imaging, and peripheral artery disease. The continuous-wave probe has four near-infrared wavelengths and uses digital detection techniques to perform measurements at 2.3 Hz. Using a multispectral evolution algorithm for chromophore reconstruction, we can measure absolute oxygenated and deoxygenated hemoglobin concentration as well as scattering in tissue. Performance of the device is demonstrated using a series of liquid phantoms comprised of Intralipid®, ink, and dye.
ERIC Educational Resources Information Center
Byrom, Elizabeth
1990-01-01
Hypermedia allows students to follow associative links among elements of nonsequential information, by combining information from multiple sources into one microcomputer-controlled system. Hypermedia products help teachers create lessons integrating text, motion film, color graphics, speech, and music, by linking such electronic devices as…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-08
... its products accused of infringement include factory-installed GPS units in certain automobiles and certain after-market ``head-unit'' GPS devices that are mounted in automobile dashboards. On September 22... (202) [[Page 1081
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-26
... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-885] Certain Portable Electronic Communications... States Code AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that a complaint was filed with the U.S. International Trade Commission on May 23, 2013, under section...
2013-02-11
calibration curves was ±5%. Ion chromatography (IC) was used for analysis of perchlorate and other ionic targets. Analysis was carried out on a...The methods utilize liquid or gas chromatography , techniques that do not lend themselves well to portable devices and methods. Portable methods are...
PORTABLE SOURCE OF RADIOACTIVITY
Goertz, R.C.; Ferguson, K.R.; Rylander, E.W.; Safranski, L.M.
1959-06-16
A portable source for radiogiaphy or radiotherapy is described. It consists of a Tl/sup 170/ or Co/sup 60/ source mounted in a rotatable tungsten alloy plug. The plug rotates within a brass body to positions of safety or exposure. Provision is made for reloading and carrying the device safely. (T.R.H.)
Gerstle, Theodore; Hassanein, Aladdin H; Eriksson, Elof
2015-01-01
The authors share their experience with the issuance of iPads to all residents, faculty, and physician extenders in their plastic surgical division. They found that these devices (1) optimized compliance with the Health Insurance Portability and Accountability Act by eliminating the use of paper service lists; (2) improved clinical efficiency; and (3) promoted resident education. They believe the use of these devices in residency is cost-effective when considering mitigating patient privacy risk and enriching educational value.
Portable receiver for radar detection
Lopes, Christopher D.; Kotter, Dale K.
2008-10-14
Various embodiments are described relating to a portable antenna-equipped device for multi-band radar detection. The detection device includes a plurality of antennas on a flexible substrate, a detection-and-control circuit, an indicator and a power source. The antenna may include one or more planar lithographic antennas that may be fabricated on a thin-film substrate. Each antenna may be tuned to a different selection frequency or band. The antennas may include a bolometer for radar detection. Each antenna may include a frequency selective surface for tuning to the selection frequency.
A prototype of a portable TDCR system at ENEA.
Capogni, Marco; De Felice, Pierino
2014-11-01
A prototype of a portable liquid scintillation counting system based on the Triple-to-Double Coincidence Ratio (TDCR) technique was developed at ENEA-INMRI in the framework of the European Metrofission project. The new device equipped with the CAEN digitizers was tested for the activity measurements of pure β-emitters ((99)Tc and (63)Ni). The list-mode data recorded by the digitizers were analyzed by software implemented in the CERN ROOT environment, which allows the application of pulse shape discrimination using the new device. Copyright © 2014 Elsevier Ltd. All rights reserved.
1999-01-01
the previous sortie. 47 Portable Maintenance Data Store (PMDS). The PMDS is a solid state memory device approximately the same size as an...Engine Titanium Consortium Portable Scanner Bridging the gap between rapid imaging and robots is a class of inspection devices called scanners...patterns on the image to change . Thus, a region approximately the size of the sensor element (3 inches in diameter) can be inspected at one time, and an
21 CFR 878.4780 - Powered suction pump.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Powered suction pump. 878.4780 Section 878.4780...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4780 Powered suction pump. (a) Identification. A powered suction pump is a portable, AC-powered or compressed air-powered device intended to be...
Hurd, Theresa; Trueman, Paul; Rossington, Alan
2014-03-01
Negative pressure wound therapy (NPWT) is widely used in the management of acute and chronic wounds. The purpose of this 8-week study was to evaluate outcomes of using a new canisterless, portable, single-use NPWT system in patients with wounds treated in a Canadian community healthcare setting. The device is designed to provide negative pressure at 80±20 mm Hg, 24 hours a day of continuous usage, for a maximum wear time of 7 days. Data on wound outcomes, including exudate levels, wound appearance, and wound area, were collected weekly by a Registered Nurse as part of routine practice. When treatment was discontinued, patients and nurses were asked to rate their satisfaction with the device. Data from patients who had used a conventional NPWT device to manage their wounds were retrospectively abstracted from their medical records. In the prospective study, conducted between October 2011 and July 2012, 326 patients (median age=61 years; range 17-91 years) with wounds of mixed etiology (53 pressure ulcers, 21 venous leg ulcers, 16 diabetic foot ulcers, and 15 traumatic and 221 surgical wounds) were treated for a maximum of 8 weeks with the portable NPWT device. The majority of patients (228 out of 326; 68%) achieved complete wound closure within 8 weeks of treatment. The Kaplan-Meier estimate of median time to healing of all wounds was 9 weeks. The majority of patients (318 patients, 97%) reported they were pleased or satisfied with the dressing performance. Nurses indicated satisfaction with the dressing performance for all but two patients (99%). The majority (89%) of patients managed with conventional NPWT (n=539) had an open surgical wound with moderate or high levels of exudate. Healing rates in the portable and conventional NPWT group were similar (10% to 11% per week). Portable, single-use NPWT has the potential to deliver good wound outcomes in community care settings and simplify the use of negative pressure for nurses and patients. Additional research is needed to evaluate treatment efficacy and cost effectiveness.
Human portable preconcentrator system
Linker, Kevin L.; Bouchier, Francis A.; Hannum, David W.; Rhykerd, Jr., Charles L.
2003-01-01
A preconcentrator system and apparatus suited to human portable use wherein sample potentially containing a target chemical substance is drawn into a chamber and through a pervious screen. The screen is adapted to capture target chemicals and then, upon heating, to release those chemicals into the chamber. Chemicals captured and then released in this fashion are then carried to a portable chemical detection device such as a portable ion mobility spectrometer. In the preferred embodiment, the means for drawing sample into the chamber comprises a reversible fan which, when operated in reverse direction, creates a backpressure that facilitates evolution of captured target chemicals into the chamber when the screen is heated.
Portable home hemodialysis for kidney failure.
Scott, A
2007-11-01
(1) Home hemodialysis has been in limited use in Canada for some time. Newer, portable hemodialysis machines that are easier for patients to operate may encourage the uptake of this technology. (2) One portable system is already available in the US. The NxStage System One hemodialysis machine operates on standard electric current, does not require plumbing or specialized disinfection, and is small enough for patients to travel with. (3) It is not yet clear whether the use of the NxStage system improves long-term survival and quality of life. (4) Home hemodialysis is less costly than conventional in-centre programs, but it is unknown whether these savings extend to portable devices.
2012-01-01
A brain-computer interface (BCI) is a communication system that can help users interact with the outside environment by translating brain signals into machine commands. The use of electroencephalographic (EEG) signals has become the most common approach for a BCI because of their usability and strong reliability. Many EEG-based BCI devices have been developed with traditional wet- or micro-electro-mechanical-system (MEMS)-type EEG sensors. However, those traditional sensors have uncomfortable disadvantage and require conductive gel and skin preparation on the part of the user. Therefore, acquiring the EEG signals in a comfortable and convenient manner is an important factor that should be incorporated into a novel BCI device. In the present study, a wearable, wireless and portable EEG-based BCI device with dry foam-based EEG sensors was developed and was demonstrated using a gaming control application. The dry EEG sensors operated without conductive gel; however, they were able to provide good conductivity and were able to acquire EEG signals effectively by adapting to irregular skin surfaces and by maintaining proper skin-sensor impedance on the forehead site. We have also demonstrated a real-time cognitive stage detection application of gaming control using the proposed portable device. The results of the present study indicate that using this portable EEG-based BCI device to conveniently and effectively control the outside world provides an approach for researching rehabilitation engineering. PMID:22284235
NASA Astrophysics Data System (ADS)
Saager, Rolf B.; Dang, An N.; Huang, Samantha S.; Kelly, Kristen M.; Durkin, Anthony J.
2017-09-01
Spatial Frequency Domain Spectroscopy (SFDS) is a technique for quantifying in-vivo tissue optical properties. SFDS employs structured light patterns that are projected onto tissues using a spatial light modulator, such as a digital micromirror device. In combination with appropriate models of light propagation, this technique can be used to quantify tissue optical properties (absorption, μa, and scattering, μs', coefficients) and chromophore concentrations. Here we present a handheld implementation of an SFDS device that employs line (one dimensional) imaging. This instrument can measure 1088 spatial locations that span a 3 cm line as opposed to our original benchtop SFDS system that only collects a single 1 mm diameter spot. This imager, however, retains the spectral resolution (˜1 nm) and range (450-1000 nm) of our original benchtop SFDS device. In the context of homogeneous turbid media, we demonstrate that this new system matches the spectral response of our original system to within 1% across a typical range of spatial frequencies (0-0.35 mm-1). With the new form factor, the device has tremendously improved mobility and portability, allowing for greater ease of use in a clinical setting. A smaller size also enables access to different tissue locations, which increases the flexibility of the device. The design of this portable system not only enables SFDS to be used in clinical settings but also enables visualization of properties of layered tissues such as skin.
On the Feasibility of Wireless Multimedia Sensor Networks over IEEE 802.15.5 Mesh Topologies
Garcia-Sanchez, Antonio-Javier; Losilla, Fernando; Rodenas-Herraiz, David; Cruz-Martinez, Felipe; Garcia-Sanchez, Felipe
2016-01-01
Wireless Multimedia Sensor Networks (WMSNs) are a special type of Wireless Sensor Network (WSN) where large amounts of multimedia data are transmitted over networks composed of low power devices. Hierarchical routing protocols typically used in WSNs for multi-path communication tend to overload nodes located within radio communication range of the data collection unit or data sink. The battery life of these nodes is therefore reduced considerably, requiring frequent battery replacement work to extend the operational life of the WSN system. In a wireless sensor network with mesh topology, any node may act as a forwarder node, thereby enabling multiple routing paths toward any other node or collection unit. In addition, mesh topologies have proven advantages, such as data transmission reliability, network robustness against node failures, and potential reduction in energy consumption. This work studies the feasibility of implementing WMSNs in mesh topologies and their limitations by means of exhaustive computer simulation experiments. To this end, a module developed for the Synchronous Energy Saving (SES) mode of the IEEE 802.15.5 mesh standard has been integrated with multimedia tools to thoroughly test video sequences encoded using H.264 in mesh networks. PMID:27164106
On the Feasibility of Wireless Multimedia Sensor Networks over IEEE 802.15.5 Mesh Topologies.
Garcia-Sanchez, Antonio-Javier; Losilla, Fernando; Rodenas-Herraiz, David; Cruz-Martinez, Felipe; Garcia-Sanchez, Felipe
2016-05-05
Wireless Multimedia Sensor Networks (WMSNs) are a special type of Wireless Sensor Network (WSN) where large amounts of multimedia data are transmitted over networks composed of low power devices. Hierarchical routing protocols typically used in WSNs for multi-path communication tend to overload nodes located within radio communication range of the data collection unit or data sink. The battery life of these nodes is therefore reduced considerably, requiring frequent battery replacement work to extend the operational life of the WSN system. In a wireless sensor network with mesh topology, any node may act as a forwarder node, thereby enabling multiple routing paths toward any other node or collection unit. In addition, mesh topologies have proven advantages, such as data transmission reliability, network robustness against node failures, and potential reduction in energy consumption. This work studies the feasibility of implementing WMSNs in mesh topologies and their limitations by means of exhaustive computer simulation experiments. To this end, a module developed for the Synchronous Energy Saving (SES) mode of the IEEE 802.15.5 mesh standard has been integrated with multimedia tools to thoroughly test video sequences encoded using H.264 in mesh networks.
47 CFR 25.129 - Equipment authorization for portable earth-station transceivers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... equipment certification procedure in part 2, Subpart J of this chapter for importation, sale or lease in the United States, or offer, shipment, or distribution for sale or lease in the United States of portable..., to devices imported, sold, leased, or offered, shipped, or distributed for sale or lease before...
Portable Linear Sled (PLS) for biomedical research
NASA Technical Reports Server (NTRS)
Vallotton, Will; Matsuhiro, Dennis; Wynn, Tom; Temple, John
1993-01-01
The PLS is a portable linear motion generating device conceived by researchers at Ames Research Center's Vestibular Research Facility and designed by engineers at Ames for the study of motion sickness in space. It is an extremely smooth apparatus, powered by linear motors and suspended on air bearings which ride on precision ground ceramic ways.
Development and Testing of a Portable Vocal Accumulator
ERIC Educational Resources Information Center
Cheyne, Harold A.; Hanson, Helen M.; Genereux, Ronald P.; Stevens, Kenneth N.; Hillman, Robert E.
2003-01-01
This research note describes the design and testing of a device for unobtrusive, long-term ambulatory monitoring of voice use, named the Portable Vocal Accumulator (PVA). The PVA contains a digital signal processor for analyzing input from a neck-placed miniature accelerometer. During its development, accelerometer recordings were obtained from 99…
47 CFR 2.1093 - Radiofrequency radiation exposure evaluation: portable devices.
Code of Federal Regulations, 2012 CFR
2012-10-01
... for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to... Exposure Criteria for Radiofrequency Electromagnetic Fields,” NCRP Report No. 86, Section 17.4.5. Copyright... Electromagnetic Fields—RF and Microwave,” IEEE C95.3-1991. (4) For purposes of analyzing portable transmitting...
Portable system for auscultation and lung sound analysis.
Nabiev, Rustam; Glazova, Anna; Olyinik, Valery; Makarenkova, Anastasiia; Makarenkov, Anatolii; Rakhimov, Abdulvosid; Felländer-Tsai, Li
2014-01-01
A portable system for auscultation and lung sound analysis has been developed, including the original electronic stethoscope coupled with mobile devices and special algorithms for the automated analysis of pulmonary sound signals. It's planned that the developed system will be used for monitoring of health status of patients with various pulmonary diseases.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-16
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-861] Certain Cases for Portable.... International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that a complaint was filed with the U.S. International Trade Commission on September 26, 2012, under section 337 of the Tariff Act of...
Fancy Walkie Talkies, Star Trek Communicators or Roving Reference?
ERIC Educational Resources Information Center
Forsyth, Ellen
2009-01-01
This paper investigates the customer service and library staff benefits of using Vocera badges (www.vocera.com), a portable wireless technology (WiFi), to facilitate roving reference service. Use of portable voice communication devices allows help to be taken to the people and away from service desks. These communication technologies allow library…
77 FR 52043 - Privacy Act of 1974; Proposed Exempt New System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-28
... study. 6. After NIH makes a finding of research misconduct and has informed ORI of the finding... Internet traffic to and from federal computer networks to prevent malicious computer code from reaching the... portable/ mobile devices including, but not limited to: Laptops, PDAs, USB drives, portable hard drives...
Kokkos: Enabling manycore performance portability through polymorphic memory access patterns
Carter Edwards, H.; Trott, Christian R.; Sunderland, Daniel
2014-07-22
The manycore revolution can be characterized by increasing thread counts, decreasing memory per thread, and diversity of continually evolving manycore architectures. High performance computing (HPC) applications and libraries must exploit increasingly finer levels of parallelism within their codes to sustain scalability on these devices. We found that a major obstacle to performance portability is the diverse and conflicting set of constraints on memory access patterns across devices. Contemporary portable programming models address manycore parallelism (e.g., OpenMP, OpenACC, OpenCL) but fail to address memory access patterns. The Kokkos C++ library enables applications and domain libraries to achieve performance portability on diversemore » manycore architectures by unifying abstractions for both fine-grain data parallelism and memory access patterns. In this paper we describe Kokkos’ abstractions, summarize its application programmer interface (API), present performance results for unit-test kernels and mini-applications, and outline an incremental strategy for migrating legacy C++ codes to Kokkos. Furthermore, the Kokkos library is under active research and development to incorporate capabilities from new generations of manycore architectures, and to address a growing list of applications and domain libraries.« less
Wood, Bayden R; Heraud, Philip; Stojkovic, Slobodanka; Morrison, Danielle; Beardall, John; McNaughton, Don
2005-08-01
We report the coupling of a portable Raman spectrometer to an acoustic levitation device to enable environmental monitoring and the potential taxonomic identification of microalgae. Spectra of living cells were recorded at 785 nm using a fiber-optic probe coupled to a portable Raman spectrometer. The spectra exhibit an excellent signal-to-noise ratio and clearly show bands from chlorophyll a and beta-carotene. Spectra of levitated photobleached microalgae clearly show a reduction in chlorophyll a concentration relative to beta-carotene after 10 min of exposure to a quartz halogen lamp. Spectra recorded from levitated nitrogen-limited cells also show a significant reduction in bands associated with chlorophyll a, as compared to nitrogen-replete cells. To investigate the diagnostic capability of the technique, four species of microalgae were analyzed. Good quality spectra of all four species were obtained showing varying ratios of beta-carotene to chlorophyll. The combination of an acoustic levitation device and a portable Raman spectrometer shows potential as a taxonomic and environmental monitoring tool with direct application to field studies in remote environments.
Sang, Shengbo; Feng, Qiliang; Jian, Aoqun; Li, Huiming; Ji, Jianlong; Duan, Qianqian; Zhang, Wendong; Wang, Tao
2016-09-20
Hemolytic anemia intensity has been suggested as a vital factor for the growth of certain clinical complications of sickle cell disease. However, there is no effective and rapid diagnostic method. As a powerful platform for bio-particles testing, biosensors integrated with microfluidics offer great potential for a new generation of portable point of care systems. In this paper, we describe a novel portable microsystem consisting of a multifunctional dielectrophoresis manipulations (MDM) device and a surface stress biosensor to separate and detect red blood cells (RBCs) for diagnosis of hemolytic anemia. The peripheral circuit to power the interdigitated electrode array of the MDM device and the surface stress biosensor test platform were integrated into a portable signal system. The MDM includes a preparing region, a focusing region, and a sorting region. Simulation and experimental results show the RBCs trajectories when they are subjected to the positive DEP force, allowing the successful sorting of living/dead RBCs. Separated RBCs are then transported to the biosensor and the capacitance values resulting from the variation of surface stress were measured. The diagnosis of hemolytic anemia can be realized by detecting RBCs and the portable microsystem provides the assessment to the hemolytic anemia patient.
Portable exothermal energy source for disaster relief operations
NASA Astrophysics Data System (ADS)
Zimbeck, Walter R.
1994-03-01
This manuscript describes an example of transfer technology from a U.S. Government Laboratory to commercial products that meet national needs in the public safety and health care sectors. Funded by the U.S. Army, the first project is the development of a portable, non-powered food warming device for serving meals to soldiers in the field. The second project is being funded by the National Institutes of Health for development of a heat therapy device for relief from rheumatoid arthritis discomfort in the hands and other affected joints. Both of these heating devices are portable, reusable heat pack products that can be regenerated in a microwave oven or in boiling water. The knowledge developed during these two projects will be applied to many other related products. Applications in support of natural and manmade disaster relief include food warming heat packs for food service to victims and rescue workers in sustained black-out conditions, and heat pack warming blankets for emergency medical situations in which patients are in traumatic shock and the onset of hypothermia is imminent.
NASA Astrophysics Data System (ADS)
Meena, Bharat Lal; Singh, Pankaj; Sah, Amar Nath; Pandey, Kiran; Agarwal, Asha; Pantola, Chayanika; Pradhan, Asima
2018-01-01
An in-house fabricated portable device has been tested to detect cervical precancer through the intrinsic fluorescence from human cervix of the whole uterus in a clinical setting. A previously validated technique based on simultaneously acquired polarized fluorescence and polarized elastic scattering spectra from a turbid medium is used to extract the intrinsic fluorescence. Using a diode laser at 405 nm, intrinsic fluorescence of flavin adenine dinucleotide, which is the dominant fluorophore and other contributing fluorophores in the epithelium of cervical tissue, has been extracted. Different grades of cervical precancer (cervical intraepithelial neoplasia; CIN) have been discriminated using principal component analysis-based Mahalanobis distance and linear discriminant analysis. Normal, CIN I and CIN II samples have been discriminated from one another with high sensitivity and specificity at 95% confidence level. This ex vivo study with cervix of whole uterus samples immediately after hysterectomy in a clinical environment indicates that the in-house fabricated portable device has the potential to be used as a screening tool for in vivo precancer detection using intrinsic fluorescence.
A green-color portable waveguide eyewear display system
NASA Astrophysics Data System (ADS)
Xia, Lingbo; Xu, Ke; Wu, Zhengming; Hu, Yingtian; Li, Zhenzhen; Wang, Yongtian; Liu, Juan
2013-08-01
Waveguide display systems are widely used in various display fields, especially in head mounted display. Comparing with the traditional head mounted display system, this device dramatically reduce the size and mass. However, there are still several fatal problems such as high scatting, the cumbersome design and chromatic aberration that should be solved. We designed and fabricated a monochromatic portable eyewear display system consist of a comfortable eyewear device and waveguide system with two holographic gratings located on the substrate symmetrically. We record the gratings on the photopolymer medium with high efficiency and wavelength sensitivity. The light emitting from the micro-display is diffracted by the grating and trapped in the glass substrate by total internal reflection. The relationship between the diffraction efficiency and exposure value is studied and analyzed, and we fabricated the gratings with appropriate diffraction efficiency in a optimization condition. To avoid the disturbance of the stray light, we optimize the waveguide system numerically and perform the optical experiments. With this system, people can both see through the waveguide to obtain the information outside and catch the information from the micro display. After considering the human body engineering and industrial production, we design the structure in a compact and portable way. It has the advantage of small-type configuration and economic acceptable. It is believe that this kind of planar waveguide system is a potentially replaceable choice for the portable devices in future mobile communications.
NASA Technical Reports Server (NTRS)
Horton, Kent; Huffman, Mitch; Eppic, Brian; White, Harrison
2005-01-01
Path Loss Measurements were obtained on three (3) GPS equipped 757 aircraft. Systems measured were Marker Beacon, LOC, VOR, VHF (3), Glide Slope, ATC (2), DME (2), TCAS, and GPS. This data will provide the basis for assessing the EMI (Electromagnetic Interference) safety margins of comm/nav (communication and navigation) systems to portable electronic device emissions. These Portable Electronic Devices (PEDs) include all devices operated in or around the aircraft by crews, passengers, servicing personnel, as well as the general public in the airport terminals. EMI assessment capability is an important step in determining if one system-wide PED EMI policy is appropriate. This data may also be used comparatively with theoretical analysis and computer modeling data sponsored by NASA Langley Research Center and others.
Cosmanescu, Alin; Miller, Benjamin; Magno, Terence; Ahmed, Assad; Kremenic, Ian
2006-01-01
A portable, multi-purpose Bio-instrumentation Amplifier and Data AcQuisition device (BADAQ) capable of measuring and transmitting EMG and EKG signals wirelessly via Bluetooth is designed and implemented. Common topologies for instrumentation amplifiers and filters are used and realized with commercially available, low-voltage, high precision operational amplifiers. An 8-bit PIC microcontroller performs 10-bit analog-to-digital conversion of the amplified and filtered signals and controls a Bluetooth transceiver capable of wirelessly transmitting the data to any Bluetooth enabled device. Electrical isolation between patient/subject, circuitry, and ancillary equipment is achieved by optocoupling components. The design focuses on simplicity, portability, and affordability.
Can we use portable nitric oxide analyzer in young children?
Kalliola, Satu; Malmberg, Pekka; Rito, Tuija; Pelkonen, Anna S; Mäkelä, Mika J
2011-07-01
Management of asthma could be improved by measuring exhaled nitric oxide (FENO). Portable hand-held FENO analyzer (NIOX MINO) is practical and small and could be used also in the primary care office. It has demonstrated good repeatability and correlation with stationary device (NIOX) in adults and school aged children, but so far there have been no reports on young children. The aim of this study was to compare conventional chemiluminescence device (NIOX) with a hand-held electrochemical device (NIOX MINO) in young children. Paired measurements of FENO were performed with the stationary chemiluminescence-based analyzer (NIOX) and with portable electrochemical device (NIOX MINO) in children with asthmatic symptoms and age-matched controls. Fifty-five children with mean (range) age of 5.7 (3.9-8.5) years were evaluated with both devices. Measurements were successful with both devices in 40 out of 57 children. NIOX MINO was more difficult to use than NIOX in this age group, success rates being 73% and 93%, respectively (P = 0.004). The reproducibility was similar and there was a close correlation between FENO measured by the two devices (r = 0.97, P < 0.001). However, Bland-Altman plot demonstrated limits of agreement that were relatively wide compared to low levels of FENO in the sample. Both devices were sensitive enough to distinguish higher FENO levels in children with asthmatic symptoms, compared to healthy controls. We conclude that NIOX MINO can be used as a screening tool for the assessment of airway inflammation in children from the age of 4 years, but its applicability is limited by lower measurement success rate and relatively poor accuracy and detection limit at low levels of FENO. Copyright © 2011 Wiley-Liss, Inc.
Considerations in Using Computer for Presentation.
ERIC Educational Resources Information Center
Lee, Shih-chung
1997-01-01
Addresses issues to consider in conducting computer presentations. Discusses presentation devices--television, multiscan capable monitor, LCD (liquid crystal display) panel with overhead projector, and video/RGB (red, green, blue) projector; lighting; audience size; and types of presentations--fast/short time multimedia presentations, oral and…
Guide Specification For Devices Used To Board Airline Passengers with Mobility Impairments
DOT National Transportation Integrated Search
2000-03-17
This advisory circular (AC) contains performance standards, specifications, and : recommendations for the design, construction, and testing of portable devices : used in the boarding of airline passengers with mobility impairments. Larger : aircraft ...
A device-dependent interface for interactive image display
NASA Technical Reports Server (NTRS)
Perkins, D. C.; Szczur, M. R.; Owings, J.; Jamros, R. K.
1984-01-01
The structure of the device independent Display Management Subsystem (DMS) and the interface routines that are available to the applications programmer for use in developing a set of portable image display utility programs are described.
Doubé, Wendy; Carding, Paul; Flanagan, Kieran; Kaufman, Jordy; Armitage, Hannah
2018-01-01
Children with speech sound disorders benefit from feedback about the accuracy of sounds they make. Home practice can reinforce feedback received from speech pathologists. Games in mobile device applications could encourage home practice, but those currently available are of limited value because they are unlikely to elaborate "Correct"/"Incorrect" feedback with information that can assist in improving the accuracy of the sound. This protocol proposes a "Wizard of Oz" experiment that aims to provide evidence for the provision of effective multimedia feedback for speech sound development. Children with two common speech sound disorders will play a game on a mobile device and make speech sounds when prompted by the game. A human "Wizard" will provide feedback on the accuracy of the sound but the children will perceive the feedback as coming from the game. Groups of 30 young children will be randomly allocated to one of five conditions: four types of feedback and a control which does not play the game. The results of this experiment will inform not only speech sound therapy, but also other types of language learning, both in general, and in multimedia applications. This experiment is a cost-effective precursor to the development of a mobile application that employs pedagogically and clinically sound processes for speech development in young children.
Doubé, Wendy; Carding, Paul; Flanagan, Kieran; Kaufman, Jordy; Armitage, Hannah
2018-01-01
Children with speech sound disorders benefit from feedback about the accuracy of sounds they make. Home practice can reinforce feedback received from speech pathologists. Games in mobile device applications could encourage home practice, but those currently available are of limited value because they are unlikely to elaborate “Correct”/”Incorrect” feedback with information that can assist in improving the accuracy of the sound. This protocol proposes a “Wizard of Oz” experiment that aims to provide evidence for the provision of effective multimedia feedback for speech sound development. Children with two common speech sound disorders will play a game on a mobile device and make speech sounds when prompted by the game. A human “Wizard” will provide feedback on the accuracy of the sound but the children will perceive the feedback as coming from the game. Groups of 30 young children will be randomly allocated to one of five conditions: four types of feedback and a control which does not play the game. The results of this experiment will inform not only speech sound therapy, but also other types of language learning, both in general, and in multimedia applications. This experiment is a cost-effective precursor to the development of a mobile application that employs pedagogically and clinically sound processes for speech development in young children. PMID:29674986
Service oriented network architecture for control and management of home appliances
NASA Astrophysics Data System (ADS)
Hayakawa, Hiroshi; Koita, Takahiro; Sato, Kenya
2005-12-01
Recent advances in multimedia network systems and mechatronics have led to the development of a new generation of applications that associate the use of various multimedia objects with the behavior of multiple robotic actors. The connection of audio and video devices through high speed multimedia networks is expected to make the system more convenient to use. For example, many home appliances, such as a video camera, a display monitor, a video recorder, an audio system and so on, are being equipped with a communication interface in the near future. Recently some platforms (i.e. UPnP1, HAVi2 and so on) are proposed for constructing home networks; however, there are some issues to be solved to realize various services by connecting different equipment via the pervasive peer-to-peer network. UPnP offers network connectivity of PCs of intelligent home appliances, practically, which means to require a PC in the network to control other devices. Meanwhile, HAVi has been developed for intelligent AV equipments with sophisticated functions using high CPU power and large memory. Considering the targets of home alliances are embedded systems, this situation raises issues of software and hardware complexity, cost, power consumption and so on. In this study, we have proposed and developed the service oriented network architecture for control and management of home appliances, named SONICA (Service Oriented Network Interoperability for Component Adaptation), to address these issues described before.
Portable control device for networked mobile robots
Feddema, John T.; Byrne, Raymond H.; Bryan, Jon R.; Harrington, John J.; Gladwell, T. Scott
2002-01-01
A handheld control device provides a way for controlling one or multiple mobile robotic vehicles by incorporating a handheld computer with a radio board. The device and software use a personal data organizer as the handheld computer with an additional microprocessor and communication device on a radio board for use in controlling one robot or multiple networked robots.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-25
... (ICAO) Dangerous Goods Panel (DGP) regarding certain lithium ion battery-powered mobility aids (e.g... devices on an aircraft and providing for the intentional removal of a lithium ion battery from a device... limit lithium ion batteries used to power portable electronic devices and medical devices to 160 watt...
Furlanetto, Karina Couto; Pitta, Fabio
2017-02-01
Patients with hypoxemia and chronic respiratory failure may need to use oxygen therapy to correct hypoxemia and to use ventilatory support to augment alveolar ventilation, reverse abnormalities in blood gases (in particular hypercapnia) and reduce the work of breathing. Areas covered: This narrative review provides an overview on the use of oxygen therapy devices or portable ventilators for improved physical activity in daily life (PADL) as well as discusses the issue of lower mobility in daily life among stable patients with chronic respiratory disease who present indication for long-term oxygen therapy (LTOT) or home-based noninvasive ventilation (NIV). A literature review of these concepts was performed by using all related search terms. Expert commentary: Technological advances led to the development of light and small oxygen therapy devices and portable ventilators which aim to facilitate patients' mobility and ambulation. However, the day-by-day dependence of a device may reduce mobility and partially impair patients' PADL. Nocturnal NIV implementation in hypercapnic patients seems promising to improve PADL. The magnitude of their equipment-related physical inactivity is underexplored up to this moment and more long-term randomized clinical trials and meta-analysis examining the effects of ambulatory oxygen and NIV on PADL are required.
Sher, Mazhar; Zhuang, Rachel; Demirci, Utkan; Asghar, Waseem
2017-01-01
Introduction There is a significant interest in developing inexpensive portable biosensing platforms for various applications including disease diagnostics, environmental monitoring, food safety, and water testing at the point-of-care (POC) settings. Current diagnostic assays available in the developed world require sophisticated laboratory infrastructure and expensive reagents. Hence, they are not suitable for resource-constrained settings with limited financial resources, basic health infrastructure, and few trained technicians. Cellulose and flexible transparency paper-based analytical devices have demonstrated enormous potential for developing robust, inexpensive and portable devices for disease diagnostics. These devices offer promising solutions to disease management in resource-constrained settings where the vast majority of the population cannot afford expensive and highly sophisticated treatment options. Areas covered In this review, the authors describe currently developed cellulose and flexible transparency paper-based microfluidic devices, device fabrication techniques, and sensing technologies that are integrated with these devices. The authors also discuss the limitations and challenges associated with these devices and their potential in clinical settings. Expert commentary In recent years, cellulose and flexible transparency paper-based microfluidic devices have demonstrated the potential to become future healthcare options despite a few limitations such as low sensitivity and reproducibility. PMID:28103450
Sher, Mazhar; Zhuang, Rachel; Demirci, Utkan; Asghar, Waseem
2017-04-01
There is a significant interest in developing inexpensive portable biosensing platforms for various applications including disease diagnostics, environmental monitoring, food safety, and water testing at the point-of-care (POC) settings. Current diagnostic assays available in the developed world require sophisticated laboratory infrastructure and expensive reagents. Hence, they are not suitable for resource-constrained settings with limited financial resources, basic health infrastructure, and few trained technicians. Cellulose and flexible transparency paper-based analytical devices have demonstrated enormous potential for developing robust, inexpensive and portable devices for disease diagnostics. These devices offer promising solutions to disease management in resource-constrained settings where the vast majority of the population cannot afford expensive and highly sophisticated treatment options. Areas covered: In this review, the authors describe currently developed cellulose and flexible transparency paper-based microfluidic devices, device fabrication techniques, and sensing technologies that are integrated with these devices. The authors also discuss the limitations and challenges associated with these devices and their potential in clinical settings. Expert commentary: In recent years, cellulose and flexible transparency paper-based microfluidic devices have demonstrated the potential to become future healthcare options despite a few limitations such as low sensitivity and reproducibility.
Limited Awareness of the Essences of Certification or Compliance Markings on Medical Devices.
Foo, Jong Yong Abdiel; Tan, Xin Ji Alan
2017-06-01
Medical devices have been long used for odiagnostic, therapeutic or rehabilitation purposes. Currently, they can range from a low-cost portable device that is often used for personal health monitoring to high-end sophisticated equipment that can only be operated by trained professionals. Depending on the functional purposes, there are different certification or compliance markings on the device when it is sold. One common certification marking is the Conformité Européenne affixation but this has a range of certification mark numbering for a variety of functional purposes. While the regulators and medical device manufacturers understand the associated significance and clinical implications, these may not be apparent to the professionals (using or maintaining the device) and the general public. With portable healthcare devices and mobile applications gaining popularity, better awareness of certification marking will be needed. Particularly, there are differences in the allowed functional purposes and the associated cost derivations of devices with a seemingly similar nature. A preferred approach such as an easy-to-understand notation next to any certification marking on a device can aid in differentiation without the need to digest mountainous regulatory details.
The Impact of Mobile Multimedia Applications on Data Center Consolidation
2012-10-01
Dell Netbook Device Used in Experiments Application Condition 1 Condition 2 Condition 3 SPEECH 0.057 s 1.04 s 4.08 s FACE 0.30 s 3.92 s N/A Figure 3...and disk capacity are secondary. Our experiments use a Dell Latitude 2102 as the mobile device. This small netbook machine is more powerful than a...device incurs the highest power dissipation. Note that the netbook platform has a high baseline idle power dissipation (around 10W), 9 Mobile 1WiFi East
49 CFR 178.255-8 - Safety devices.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false Safety devices. 178.255-8 Section 178.255-8 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... Portable Tanks § 178.255-8 Safety devices. (a) See § 173.315(i) of this subchapter. (b) [Reserved] [Amdt...
49 CFR 178.255-8 - Safety devices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 2 2010-10-01 2010-10-01 false Safety devices. 178.255-8 Section 178.255-8 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... Specifications for Portable Tanks § 178.255-8 Safety devices. (a) See § 173.315(i) of this subchapter. (b...
Portable liquid collection electrostatic precipitator
Carlson, Duane C.; DeGange, John J.; Halverson, Justin E.
2005-10-18
A portable liquid collection electrostatic collection precipitator for analyzing air is provided which is a relatively small, self-contained device. The device has a tubular collection electrode, a reservoir for a liquid, and a pump. The pump pumps the liquid into the collection electrode such that the liquid flows down the exterior of the collection electrode and is recirculated to the reservoir. An air intake is provided such that air to be analyzed flows through an ionization section to ionize analytes in the air, and then flows near the collection electrode where ionized analytes are collected. A portable power source is connected to the air intake and the collection electrode. Ionizable constituents in the air are ionized, attracted to the collection electrode, and precipitated in the liquid. The precipitator may also have an analyzer for the liquid and may have a transceiver allowing remote operation and data collection.
Bandera, Cesar
2016-05-25
The Office of Public Health Preparedness and Response (OPHPR) in the Centers for Disease Control and Prevention conducts outreach for public preparedness for natural and manmade incidents. In 2011, OPHPR conducted a nationwide mobile public health (m-Health) campaign that pushed brief videos on preparing for severe winter weather onto cell phones, with the objective of evaluating the interoperability of multimedia m-Health outreach with diverse cell phones (including handsets without Internet capability), carriers, and user preferences. Existing OPHPR outreach material on winter weather preparedness was converted into mobile-ready multimedia using mobile marketing best practices to improve audiovisual quality and relevance. Middleware complying with opt-in requirements was developed to push nine bi-weekly multimedia broadcasts onto subscribers' cell phones, and OPHPR promoted the campaign on its web site and to subscribers on its govdelivery.com notification platform. Multimedia, text, and voice messaging activity to/from the middleware was logged and analyzed. Adapting existing media into mobile video was straightforward using open source and commercial software, including web pages, PDF documents, and public service announcements. The middleware successfully delivered all outreach videos to all participants (a total of 504 videos) regardless of the participant's device. 54 % of videos were viewed on cell phones, 32 % on computers, and 14 % were retrieved by search engine web crawlers. 21 % of participating cell phones did not have Internet access, yet still received and displayed all videos. The time from media push to media viewing on cell phones was half that of push to viewing on computers. Video delivered through multimedia messaging can be as interoperable as text messages, while providing much richer information. This may be the only multimedia mechanism available to outreach campaigns targeting vulnerable populations impacted by the digital divide. Anti-spam laws preserve the integrity of mobile messaging, but complicate campaign promotion. Person-to-person messages may boost enrollment.
Detection and location of metal fragments in the human body
NASA Technical Reports Server (NTRS)
Brown, R. L.; Neuschaefer, R. W.
1970-01-01
Portable electronic device, based on the design of an eddy current gage, detects ferrous and nonferrous metal fragments. Device is more easily transported than X-ray equipment and does not present a radiation hazard.
3D-printed components for quantum devices.
Saint, R; Evans, W; Zhou, Y; Barrett, T; Fromhold, T M; Saleh, E; Maskery, I; Tuck, C; Wildman, R; Oručević, F; Krüger, P
2018-05-30
Recent advances in the preparation, control and measurement of atomic gases have led to new insights into the quantum world and unprecedented metrological sensitivities, e.g. in measuring gravitational forces and magnetic fields. The full potential of applying such capabilities to areas as diverse as biomedical imaging, non-invasive underground mapping, and GPS-free navigation can only be realised with the scalable production of efficient, robust and portable devices. We introduce additive manufacturing as a production technique of quantum device components with unrivalled design freedom and rapid prototyping. This provides a step change in efficiency, compactness and facilitates systems integration. As a demonstrator we present an ultrahigh vacuum compatible ultracold atom source dissipating less than ten milliwatts of electrical power during field generation to produce large samples of cold rubidium gases. This disruptive technology opens the door to drastically improved integrated structures, which will further reduce size and assembly complexity in scalable series manufacture of bespoke portable quantum devices.
Li, Zhi; Durgin, Frank H
2011-06-01
Palm boards are often used as a nonverbal measure in human slant perception studies. It was recently found that palm boards are biased and relatively insensitive measures, and that an unrestricted hand gesture provides a more sensitive response (Durgin, Hajnal, Li, Tonge, & Stigliani, Acta Psychologica, 134, 182-197, 2010a). In this article, we describe an original design for a portable lightweight digital device for measuring hand orientation. This device is microcontroller-based and uses a micro inclinometer chip as its inclination sensor. The parts are fairly inexpensive. This device, used to measure hand orientation, provides a sensitive nonverbal method for studying slant perception, which can be used in both indoor and outdoor environments. We present data comparing the use of a free hand to palm-board and verbal measures for surfaces within reach and explain how to interpret free-hand measures for outdoor hills.
Mak, Yim Wah; Wu, Cynthia Sau Ting; Hui, Donna Wing Shun; Lam, Siu Ping; Tse, Hei Yin; Yu, Wing Yan; Wong, Ho Ting
2014-10-28
Screen viewing is considered to have adverse impacts on the sleep of adolescents. Although there has been a considerable amount of research on the association between screen viewing and sleep, most studies have focused on specific types of screen viewing devices such as televisions and computers. The present study investigated the duration with which currently prevalent screen viewing devices (including televisions, personal computers, mobile phones, and portable video devices) are viewed in relation to sleep duration, sleep quality, and daytime sleepiness among Hong Kong adolescents (N = 762). Television and computer viewing remain prevalent, but were not correlated with sleep variables. Mobile phone viewing was correlated with all sleep variables, while portable video device viewing was shown to be correlated only with daytime sleepiness. The results demonstrated a trend of increase in the prevalence and types of screen viewing and their effects on the sleep patterns of adolescents.
Ultra low-cost, portable smartphone optosensors for mobile point-of-care diagnostics
NASA Astrophysics Data System (ADS)
Wang, Li-Ju; Chang, Yu-Chung; Sun, Rongrong; Li, Lei
2018-02-01
Smartphone optosensors with integrated optical components make mobile point-of-care (MPoC) diagnostics be done near patients' side. It'll especially have a significant impact on healthcare delivery in rural or remote areas. Current FDA-approved PoC devices achieving clinical level are still at high cost and not affordable in rural hospitals. We present a series of ultra low-cost smartphone optical sensing devices for mobile point-of-care diagnosis. Aiming different targeting analytes and sensing mechanisms, we developed custom required optical components for each smartphone optosensros. These optical devices include spectrum readers, colorimetric readers for microplate, lateral flow device readers, and chemiluminescence readers. By integrating our unique designed optical components into smartphone optosening platform, the anlaytes can be precisely detected. Clinical testing results show the clinical usability of our smartphone optosensors. Ultra low-cost portable smartphone optosensors are affordable for rural/remote doctors.
Miniaturized, Portable Sensors Monitor Metabolic Health
NASA Technical Reports Server (NTRS)
2014-01-01
In order to measure astronauts' metabolic rates in space, Glenn Research Center partnered with Case Western University and the Cleveland Clinic to develop the Portable Unit for Metabolic Analysis (PUMA). Cleveland-based Orbital Research licensed and then modified PUMA to help the US Navy assess pilot oxygen problems and is now designing a device that can be used in hospitals.
Teaching Adults with Moderate Intellectual Disability ATM Use via the "iPod"
ERIC Educational Resources Information Center
Scott, Renee; Collins, Belva; Knight, Victoria; Kleinert, Harold
2013-01-01
Money management can increase independence and access to communities for individuals with disabilities. Although research on computer-based instruction for teaching banking skills to students with intellectual disability is established, the use of portable electronic devices (e.g., iPod) has not been evaluated. iPods may be an effective, portable,…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-07
...--Equities That Would Not Permit Designated Market Makers and Floor Brokers To Use Personal Portable Phone... Earlier of When Phone Service is Fully Restored or Friday, November 2, 2012 November 1, 2012. Pursuant to... (``DMMs'') and Floor brokers to use personal portable phone devices on the Trading Floor following the...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-19
... Not Permit Floor Brokers To Use Personal Portable Phone Devices on the Trading Floor following the Aftermath of Hurricane Sandy Until the Earlier of When Phone Service Is Fully Restored or Friday, November....20--Equities and 36.21--Equities that would not permit Floor brokers to use personal portable phone...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-07
... Permit Designated Market Makers and Floor Brokers To Use Personal Portable Phone Devices on the Trading Floor Following the Aftermath of Hurricane Sandy From October 31, 2012 Until the Earlier of When Phone... would not permit Designated Market Makers (``DMMs'') and Floor brokers to use personal portable phone...
75 FR 739 - Use of Additional Portable Oxygen Concentrator Devices on Board Aircraft
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-06
...;Prices of new books are listed in the first FEDERAL REGISTER issue of each #0;week. #0; #0; #0; #0;#0... approved by the Food and Drug Administration (FDA) reduce the risks typically associated with compressed... developed small portable oxygen concentrators (POC) that work by separating oxygen from nitrogen and other...
An Ethical Dilemma: Talking about Plagiarism and Academic Integrity in the Digital Age
ERIC Educational Resources Information Center
Thomas, Ebony Elizabeth; Sassi, Kelly
2011-01-01
Today, many students not only access the Internet through desktop and laptop computers at home or at school but also have copious amounts of information at their fingertips via portable devices (e.g., iPods, iPads, netbooks, smartphones). While some teachers welcome the proliferation of portable technologies and easy wireless Internet access, and…
Li, Bowei; Fu, Longwen; Zhang, Wei; Feng, Weiwei; Chen, Lingxin
2014-04-01
This paper presents a novel paper-based analytical device based on the colorimetric paper assays through its light reflectance. The device is portable, low cost (<20 dollars), and lightweight (only 176 g) that is available to assess the cost-effectiveness and appropriateness of the original health care or on-site detection information. Based on the light reflectance principle, the signal can be obtained directly, stably and user-friendly in our device. We demonstrated the utility and broad applicability of this technique with measurements of different biological and pollution target samples (BSA, glucose, Fe, and nitrite). Moreover, the real samples of Fe (II) and nitrite in the local tap water were successfully analyzed, and compared with the standard UV absorption method, the quantitative results showed good performance, reproducibility, and reliability. This device could provide quantitative information very conveniently and show great potential to broad fields of resource-limited analysis, medical diagnostics, and on-site environmental detection. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Entropy for the Complexity of Physiological Signal Dynamics.
Zhang, Xiaohua Douglas
2017-01-01
Recently, the rapid development of large data storage technologies, mobile network technology, and portable medical devices makes it possible to measure, record, store, and track analysis of biological dynamics. Portable noninvasive medical devices are crucial to capture individual characteristics of biological dynamics. The wearable noninvasive medical devices and the analysis/management of related digital medical data will revolutionize the management and treatment of diseases, subsequently resulting in the establishment of a new healthcare system. One of the key features that can be extracted from the data obtained by wearable noninvasive medical device is the complexity of physiological signals, which can be represented by entropy of biological dynamics contained in the physiological signals measured by these continuous monitoring medical devices. Thus, in this chapter I present the major concepts of entropy that are commonly used to measure the complexity of biological dynamics. The concepts include Shannon entropy, Kolmogorov entropy, Renyi entropy, approximate entropy, sample entropy, and multiscale entropy. I also demonstrate an example of using entropy for the complexity of glucose dynamics.
Zeinhom, Mohamed Maarouf Ali; Wang, Yijia; Song, Yang; Zhu, Mei-Jun; Lin, Yuehe; Du, Dan
2018-01-15
The detection of E. coli O157:H7 in foods has held the attention of many researchers because of the seriousness attributed to this pathogen. In this study, we present a simple, sensitive, rapid and portable smartphone based fluorescence device for E. coli O157:H7 detection. This field-portable fluorescent imager on the smartphone involves a compact laser-diode-based photosource, a long-pass (LP) thin-film interference filter and a high-quality insert lenses. The design of the device provided a low noise to background imaging system. Based on a sandwich ELISA and the specific recognition of antibody to E. coli O157:H7, the sensitive detection of E. coli O157:H7 were realized both in standard samples and real matrix in yoghurt and egg on our device. The detection limit are 1 CFU/mL and 10 CFU/mL correspondingly. Recovery percentages of spiked yogurt and egg samples with 10 3 , 10 4 and 10 5 CFU/mL E. coli O157:H7 were 106.98, 96.52 and 102.65 (in yogurt) and 107.37, 105.64 and 93.84 (in egg) samples using our device, respectively. Most importantly, the entire process could be quickly completed within two hours. This smartphone based device provides a simple, rapid, sensitive detection platform for fluorescent imaging which applied in pathogen detection for food safety monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.
Berliner, Jonathan L; Ortiz, Philippe A; Lee, Yuo-Yu; Miller, Theodore T; Westrich, Geoffrey H
2018-01-01
Improvements in device design have allowed for portable pneumatic compression devices (PPCDs). However, portability results in smaller pumps that move less blood. Additionally, although patients often stand when wearing PPCDs, few studies have evaluated the hemodynamic effects of PCDs while standing. A crossover study was performed to compare a PPCD (ActiveCare+S.F.T.; Medical Compression Systems, Or Akiva, Israel) to a stationary pneumatic compression device (SPCD) (VenaFlow; DJO Global, Carlsbad, CA) on hemodynamics in supine and standing positions among 2 cohorts composed of 10 controls and 10 total hip arthroplasty patients. Differences in baseline peak venous velocity (PVV), PVV with each PCD, and delta PVV with each PCD were assessed. A multivariate analysis was performed to examine differences between cohorts, devices, and position. In both positions, the SPCD demonstrated a larger change in PVV when compared to the PPCD (P < .001). The total hip arthroplasty group had a greater delta PVV while standing when considering both PCDs together (P < .001). When considering both cohorts, delta PVV was greater while standing, only when the SPCD was used (P < .001). There was no difference between standing and supine positions when the PPCD was used. The SPCD demonstrated a greater capacity to increase PPV in the supine and standing positions. The SPCD generated greater values of PVV and delta PVV in the standing position. Although these results demonstrate a difference between devices, it is important to establish the PVV necessary to prevent VTE before one is considered more effective. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Ergenç, Duygu; Freire, David; Fort, Rafael
2016-04-01
The chemical characterization of lime mortars used in Roman period has a great significance and plays a key role in the acquisition of knowledge with respect to construction technology, raw materials and, accordingly, in its conservation works. When it comes to cultural heritage studies, sampling is always complicated since the minimum damage is the primary concern. The use of non-destructive techniques and direct measurements with portable devices reduce the amount of samples and time consumed in analyses, consequently it could be stated that such techniques are extremely useful in conservation and restoration works. In this study, the portable XRF device was used to determine the composition of chemical elements which compose the Roman lime mortars in the archaeological site of Complutum, Alcalá de Henares (Madrid, Spain) which is listed as a World Heritage Site by UNESCO since 1998. Portable XRF devices have some detection limits below the ones of the laboratory equipment that are immovable and require sampling. In order to correlate the results, sampling and grinding were initially done to prepare the powders for the laboratory XRF analysis with the following elements: Si, Al, Fe, Ca, Mg, K, Ti, Nb, Zr, Sr, Rb, Pb, Zn and Cr. The analyses of the powdered samples were conducted with the laboratory equipment PHILIPS Magix Pro (PW-2440) from the Centre of Scientific Instrumentation CIC in the University of Granada, and the results were compared to the results gathered with X Ray Florescence (EDTRX) THERMO NITON model XL3T from the Petrophysics Laboratory Geosciences Institute IGEO (CSIC-UCM). Analyses were performed on the surfaces of the samples -without any previous preparation-, and on the powdered samples to compare the variations between both traditional XRF analyses and the portable XRF. A good correlation was found among the results obtained by the laboratory equipment, the portable device as well as the surface measurements. The results of this study enable to differentiate the types of lime mortars used in the site (Caementicium and Signinum) and in different buildings that form the Roman city. Acknowledgements: Thanks to the project CLIMORTEC (BIA2014-53911-R), to CEI-Moncloa of UCM-UPM-UCM and to Madrid Community for funding the Geomateriales2 (P2013/MIT2914) program
Microfluidics-Based Lab-on-Chip Systems in DNA-Based Biosensing: An Overview
Dutse, Sabo Wada; Yusof, Nor Azah
2011-01-01
Microfluidics-based lab-on-chip (LOC) systems are an active research area that is revolutionising high-throughput sequencing for the fast, sensitive and accurate detection of a variety of pathogens. LOCs also serve as portable diagnostic tools. The devices provide optimum control of nanolitre volumes of fluids and integrate various bioassay operations that allow the devices to rapidly sense pathogenic threat agents for environmental monitoring. LOC systems, such as microfluidic biochips, offer advantages compared to conventional identification procedures that are tedious, expensive and time consuming. This paper aims to provide a broad overview of the need for devices that are easy to operate, sensitive, fast, portable and sufficiently reliable to be used as complementary tools for the control of pathogenic agents that damage the environment. PMID:22163925
Liu, Bin; Tan, Dongsheng; Wang, Xianfu; Chen, Di; Shen, Guozhen
2013-06-10
Flexible and highly efficient energy storage units act as one of the key components in portable electronics. In this work, by planar-integrated assembly of hierarchical ZnCo₂O₄ nanowire arrays/carbon fibers electrodes, a new class of flexible all-solid-state planar-integrated fiber supercapacitors are designed and produced via a low-cost and facile method. The as-fabricated flexible devices exhibit high-efficiency, enhanced capacity, long cycle life, and excellent electrical stability. An enhanced distributed-capacitance effect is experimentally observed for the device. This strategy enables highly flexible new structured supercapacitors with maximum functionality and minimized size, thus making it possible to be readily applied in flexible/portable photoelectronic devices. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Preliminary design of betavoltaic battery using Co-60 and Pm-147 with GaAs substrate
NASA Astrophysics Data System (ADS)
Waris, A.; Kusumawati, Y.; Alfarobi, A. S.; Aji, I. K.; Basar, K.
2016-03-01
Battery is very important for the present daily life, especially for portable devices. The longer utilization time the better performance of battery. Betavoltaic battery is a device that converts energy from beta decays of radioactive nuclide into electric current. One of merits of the later battery is the life time that can be more than ten years without recharging. To develop the betavoltaic battery for energy source of portable devices we have performed a preliminary simulation design of betavoltaic battery using Pm-147 and Co-60 a beta emitter radionuclides with n-GaAs substrate. From the results we found that the combination of Pm-147 with n-GaAs substrate results in 9.0% of efficiency and higher output current compared to references.
Technological choices for mobile clinical applications.
Ehrler, Frederic; Issom, David; Lovis, Christian
2011-01-01
The rise of cheaper and more powerful mobile devices make them a new and attractive platform for clinical applications. The interaction paradigm and portability of the device facilitates bedside human-machine interactions. The better accessibility to information and decision-support anywhere in the hospital improves the efficiency and the safety of care processes. In this study, we attempt to find out what are the most appropriate Operating System (OS) and Software Development Kit (SDK) to support the development of clinical applications on mobile devices. The Android platform is a Linux-based, open source platform that has many advantages. Two main SDKs are available on this platform: the native Android and the Adobe Flex SDK. Both of them have interesting features, but the latter has been preferred due its portability at comparable performance and ease of development.
Device Assists Cardiac Chest Compression
NASA Technical Reports Server (NTRS)
Eichstadt, Frank T.
1995-01-01
Portable device facilitates effective and prolonged cardiac resuscitation by chest compression. Developed originally for use in absence of gravitation, also useful in terrestrial environments and situations (confined spaces, water rescue, medical transport) not conducive to standard manual cardiopulmonary resuscitation (CPR) techniques.
Reliability of a portable device for the detection of sleep bruxism.
Deregibus, Andrea; Castroflorio, Tommaso; Bargellini, Andrea; Debernardi, Cesare
2014-11-01
The aim of the study was to assess the repeatability in detecting sleep bruxism (SB) episodes by combined surface electromyography and heart rate (HR) signals recorded by a compact portable device (Bruxoff®). SB episodes are preceded by a sudden HR change. Thus, HR detection increases the precision of automatic detection of SB. Ten healthy subjects (five women and five men; 30.2 ± 11.02 years) were selected for the study. Rhythmic masseter muscle activities, constituting the basic pattern of SB, were detected during three nights of recording during three different weeks with the Bruxoff device. The two-way ANOVA was not significant for SB episodes per night, SB episodes per hour, and heart frequency: no significant differences were observed during the three different nights of recording for each of the abovementioned variables (P > 0.05). The intraclass correlation coefficient showed a good reproducibility for SB episodes per night (69 %), SB per hour (74 %), and heart frequency (82 %). A poor reproducibility was revealed for the number of masseter contractions (53 %). The Pearson analysis showed the absence of a significant correlation between the number of masseter contractions per night and the number of SB episodes per night (r = -0.02, P = 0.91). The Bruxoff device showed a good reproducibility of measurements of sleep bruxism episodes over time. These findings are important in the light of the need for simple and reliable portable devices for the diagnosis of SB both in the clinical and research settings.
reflect it. There are commercially available manual and powered suction devices on the market , and several are specifically advertised for use in...combine to suggest that no device on the market meets even the most basic requirements of being small, lightweight, rugged, and demonstrating adequate
reflect it. There are commercially available manual and powered suction devices on the market , and several are specifically advertised for use in...combine to suggest that no device on the market meets even the most basic requirements of being small, lightweight, rugged, and demonstrating adequate
Recent Developments in Home Sleep-Monitoring Devices
Kelly, Jessica M.; Strecker, Robert E.; Bianchi, Matt T.
2012-01-01
Improving our understanding of sleep physiology and pathophysiology is an important goal for both medical and general wellness reasons. Although the gold standard for assessing sleep remains the laboratory polysomnogram, there is an increasing interest in portable monitoring devices that provide the opportunity for assessing sleep in real-world environments such as the home. Portable devices allow repeated measurements, evaluation of temporal patterns, and self-experimentation. We review recent developments in devices designed to monitor sleep-wake activity, as well as monitors designed for other purposes that could in principle be applied in the field of sleep (such as cardiac or respiratory sensing). As the body of supporting validation data grows, these devices hold promise for a variety of health and wellness goals. From a clinical and research standpoint, the capacity to obtain longitudinal sleep-wake data may improve disease phenotyping, individualized treatment decisions, and individualized health optimization. From a wellness standpoint, commercially available devices may allow individuals to track their own sleep with the goal of finding patterns and correlations with modifiable behaviors such as exercise, diet, and sleep aids. PMID:23097718
Multimedia CALLware: The Developer's Responsibility.
ERIC Educational Resources Information Center
Dodigovic, Marina
The early computer-assisted-language-learning (CALL) programs were silent and mostly limited to screen or printer supported written text as the prevailing communication resource. The advent of powerful graphics, sound and video combined with AI-based parsers and sound recognition devices gradually turned the computer into a rather anthropomorphic…
MALL Technology: Use of Academic Podcasting in the Foreign Language Classroom
ERIC Educational Resources Information Center
Abdous, M'hammed; Camarena, Margaret M.; Facer, Betty Rose
2009-01-01
Integrating Mobile Assisted Language Learning (MALL) technology (personal multimedia players, cell phones, and handheld devices) into the foreign language curriculum is becoming commonplace in many secondary and higher education institutions. Current research has identified both pedagogically sound applications and important benefits to students.…
Schwebel, David C.; Stavrinos, Despina; Byington, Katherine W.; Davis, Tiffany; O’Neal, Elizabeth E.; de Jong, Desiree
2011-01-01
As use of handheld multimedia devices has exploded globally, safety experts have begun to consider the impact of distraction while talking, text-messaging, or listening to music on traffic safety. This study was designed to test how talking on the phone, texting, and listening to music may influence pedestrian safety. 138 college students crossed an interactive, semi-immersive virtual pedestrian street. They were randomly assigned to one of four groups: crossing while talking on the phone, crossing while texting, crossing while listening to a personal music device, or crossing while undistracted. Participants distracted by music or texting were more likely to be hit by a vehicle in the virtual pedestrian environment than were undistracted participants. Participants in all three distracted groups were more likely to look away from the street environment (and look toward other places, such as their telephone or music device) than were undistracted participants. Findings were maintained after controlling for demographics, walking frequency, and media use frequency. Distraction from multimedia devices has a small but meaningful impact on college students’ pedestrian safety. Future research should consider the cognitive demands of pedestrian safety, and how those processes may be impacted by distraction. Policymakers might consider ways to protect distracted pedestrians from harm and to reduce the number of individuals crossing streets while distracted. PMID:22269509
Schwebel, David C; Stavrinos, Despina; Byington, Katherine W; Davis, Tiffany; O'Neal, Elizabeth E; de Jong, Desiree
2012-03-01
As use of handheld multimedia devices has exploded globally, safety experts have begun to consider the impact of distraction while talking, text-messaging, or listening to music on traffic safety. This study was designed to test how talking on the phone, texting, and listening to music may influence pedestrian safety. 138 college students crossed an interactive, semi-immersive virtual pedestrian street. They were randomly assigned to one of four groups: crossing while talking on the phone, crossing while texting, crossing while listening to a personal music device, or crossing while undistracted. Participants distracted by music or texting were more likely to be hit by a vehicle in the virtual pedestrian environment than were undistracted participants. Participants in all three distracted groups were more likely to look away from the street environment (and look toward other places, such as their telephone or music device) than were undistracted participants. Findings were maintained after controlling for demographics, walking frequency, and media use frequency. Distraction from multimedia devices has a small but meaningful impact on college students' pedestrian safety. Future research should consider the cognitive demands of pedestrian safety, and how those processes may be impacted by distraction. Policymakers might consider ways to protect distracted pedestrians from harm and to reduce the number of individuals crossing streets while distracted. Copyright © 2011 Elsevier Ltd. All rights reserved.
A portable system for foot biomechanical analysis during gait.
Samson, William; Sanchez, Stéphane; Salvia, Patrick; Jan, Serge Van Sint; Feipel, Véronique
2014-07-01
Modeling the foot is challenging due to its complex structure compared to most other body segments. To analyze the biomechanics of the foot, portable devices have been designed to allow measurement of temporal, spatial, and pedobarographic parameters. The goal of this study was to design and evaluate a portable system for kinematic and dynamic analysis of the foot during gait. This device consisted of a force plate synchronized with four cameras and integrated into a walkway. The complete system can be packaged for transportation. First, the measurement system was assessed using reference objects to evaluate accuracy and precision. Second, nine healthy participants were assessed during gait trials using both the portable and Vicon systems (coupled with a force plate). The ankle and metatarsophalangeal (MP) joint angles and moments were computed, as well as the ground reaction force (GRF). The intra- and inter-subject variability was analyzed for both systems, as well as the inter-system variation. The accuracy and precision were, respectively 0.4 mm and 0.4 mm for linear values and 0.5° and 0.6° for angular values. The variability of the portable and Vicon systems were similar (i.e., the inter-system variability never exceeded 2.1°, 0.081 Nmkg(-1) and 0.267 Nkg(-1) for the angles, moments and GRF, respectively). The inter-system differences were less than the inter-subject variability and similar to the intra-subject variability. Consequently, the portable system was considered satisfactory for biomechanical analysis of the foot, outside of a motion analysis laboratory. Copyright © 2014 Elsevier B.V. All rights reserved.
Semiclosed-circuit atmosphere control in a portable recompression chamber
NASA Technical Reports Server (NTRS)
Riegel, P. S.; Caudy, D. W.
1972-01-01
A small portable recompression chamber is described that can be used both to treat a diver for decompression sickness or to transport him to a larger chamber complex. The device can be operated in either open circuit or semiclosed circuit atmospheres, permits two way conversation between patient and attendant, and uses an air injector for circulation of the chamber atmosphere.
Portable dynamic fundus instrument
NASA Technical Reports Server (NTRS)
Taylor, Gerald R. (Inventor); Meehan, Richard T. (Inventor); Hunter, Norwood R. (Inventor); Caputo, Michael P. (Inventor); Gibson, C. Robert (Inventor)
1992-01-01
A portable diagnostic image analysis instrument is disclosed for retinal funduscopy in which an eye fundus image is optically processed by a lens system to a charge coupled device (CCD) which produces recordable and viewable output data and is simultaneously viewable on an electronic view finder. The fundus image is processed to develop a representation of the vessel or vessels from the output data.
Development of a Portable Taste Sensor with a Lipid/Polymer Membrane
Tahara, Yusuke; Nakashi, Kenichi; Ji, Ke; Ikeda, Akihiro; Toko, Kiyoshi
2013-01-01
We have developed a new portable taste sensor with a lipid/polymer membrane and conducted experiments to evaluate the sensor's performance. The fabricated sensor consists of a taste sensor chip (40 mm × 26 mm × 2.2 mm) with working and reference electrodes and a portable sensor device (80 mm × 25 mm × 20 mm). The working electrode consists of a taste-sensing site comprising a poly(hydroxyethyl)methacrylate (pHEMA) hydrogel layer with KCl as the electrolyte layer and a lipid/polymer membrane as the taste sensing element. The reference electrode comprises a polyvinyl chloride (PVC) membrane layer with a small hole and a pHEMA layer with KCl. The whole device is the size of a USB memory stick, making it suitable for portable use. The sensor's response to tannic acid as the standard astringency substance showed good accuracy and reproducibility, and was comparable with the performance of a commercially available taste sensing system. Thus, it is possible for this sensor to be used for in-field evaluations and it can make a significant contribution to the food industry, as well as in various fields of research. PMID:23325168
Micro-machined thermo-conductivity detector
Yu, Conrad
2003-01-01
A micro-machined thermal conductivity detector for a portable gas chromatograph. The detector is highly sensitive and has fast response time to enable detection of the small size gas samples in a portable gas chromatograph which are in the order of nanoliters. The high sensitivity and fast response time are achieved through micro-machined devices composed of a nickel wire, for example, on a silicon nitride window formed in a silicon member and about a millimeter square in size. In addition to operating as a thermal conductivity detector, the silicon nitride window with a micro-machined wire therein of the device can be utilized for a fast response heater for PCR applications.
Gait mode recognition and control for a portable-powered ankle-foot orthosis.
David Li, Yifan; Hsiao-Wecksler, Elizabeth T
2013-06-01
Ankle foot orthoses (AFOs) are widely used as assistive/rehabilitation devices to correct the gait of people with lower leg neuromuscular dysfunction and muscle weakness. We have developed a portable powered ankle-foot orthosis (PPAFO), which uses a pneumatic bi-directional rotary actuator powered by compressed CO2 to provide untethered dorsiflexor and plantarflexor assistance at the ankle joint. Since portability is a key to the success of the PPAFO as an assist device, it is critical to recognize and control for gait modes (i.e. level walking, stair ascent/descent). While manual mode switching is implemented in most powered orthotic/prosthetic device control algorithms, we propose an automatic gait mode recognition scheme by tracking the 3D position of the PPAFO from an inertial measurement unit (IMU). The control scheme was designed to match the torque profile of physiological gait data during different gait modes. Experimental results indicate that, with an optimized threshold, the controller was able to identify the position, orientation and gait mode in real time, and properly control the actuation. It was also illustrated that during stair descent, a mode-specific actuation control scheme could better restore gait kinematic and kinetic patterns, compared to using the level ground controller.
Portable Virtual Training Units
NASA Technical Reports Server (NTRS)
Malone, Reagan; Johnston, Alan
2015-01-01
The Mission Operations Lab initiated a project to design, develop, deliver, test, and validate a unique training system for astronaut and ground support personnel. In an effort to keep training costs low, virtual training units (VTUs) have been designed based on images of actual hardware and manipulated by a touch screen style interface for ground support personnel training. This project helped modernized the training system and materials by integrating them with mobile devices for training when operators or crew are unavailable to physically train in the facility. This project also tested the concept of a handheld remote device to control integrated trainers using International Space Station (ISS) training simulators as a platform. The portable VTU can interface with the full-sized VTU, allowing a trainer co-located with a trainee to remotely manipulate a VTU and evaluate a trainee's response. This project helped determine if it is useful, cost effective, and beneficial for the instructor to have a portable handheld device to control the behavior of the models during training. This project has advanced NASA Marshall Space Flight Center's (MSFC's) VTU capabilities with modern and relevant technology to support space flight training needs of today and tomorrow.
NASA Technical Reports Server (NTRS)
Lovelady, R. W.; Ferguson, R. L.
1975-01-01
Self-powered sonar device may be implanted in body of fish. It transmits signal that can be detected with portable tracking gear or by automatic detection-and-tracking system. Operating life of over 4000 hours may be expected. Device itself may be used almost indefinitely.
Feasibility of Bluetooth Data as a Surrogate Measure of Vehicle Operations : Technical Summary
DOT National Transportation Integrated Search
2012-10-01
The widespread use of portable electronic devices among consumers has allowed new opportunities for traffic data collection. Many of these devices contain short-range Bluetooth radios in addition to other electronic equipment. The included Bluetooth ...
Collett, Catherine; Ardron, Alia; Bauer, Ulrike; Chapman, Gary; Chaudan, Elodie; Hallmark, Bart; Pratt, Lee; Torres-Perez, Maria Dolores; Wilson, D Ian
2015-01-01
Biological fluids often have interesting and unusual physical properties to adapt them for their specific purpose. Laboratory-based rheometers can be used to characterise the viscoelastic properties of such fluids. This, however, can be challenging as samples often do not retain their natural properties in storage while conventional rheometers are fragile and expensive devices ill-suited for field measurements. We present a portable, low-cost extensional rheometer designed specifically to enable in situ studies of biological fluids in the field. The design of the device (named Seymour) is based on a conventional capillary break-up extensional rheometer (the Cambridge Trimaster). It works by rapidly stretching a small fluid sample between two metal pistons. A battery-operated solenoid switch triggers the pistons to move apart rapidly and a compact, robust and inexpensive, USB 3 high speed camera is used to record the thinning and break-up of the fluid filament that forms between the pistons. The complete setup runs independently of mains electricity supply and weighs approximately 1 kg. Post-processing and analysis of the recorded images to extract rheological parameters is performed using open source software. The device was tested both in the laboratory and in the field, in Brunei Darussalam, using calibration fluids (silicone oil and carboxymethyl cellulose solutions) as well as Nepenthes pitcher plant trapping fluids as an example of a viscoelastic biological fluid. The fluid relaxation times ranged from 1 ms to over 1 s. The device gave comparable performance to the Cambridge Trimaster. Differences in fluid viscoelasticity between three species were quantified, as well as the change in viscoelasticity with storage time. This, together with marked differences between N. rafflesiana fluids taken from greenhouse and wild plants, confirms the need for a portable device. Proof of concept of the portable rheometer was demonstrated. Quantitative measurements of pitcher plant fluid viscoelasticity were made in the natural habitat for the first time. The device opens up opportunities for studying a wide range of plant fluids and secretions, under varying experimental conditions, or with changing temperatures and weather conditions.
Enhanced data consistency of a portable gait measurement system.
Lin, Hsien-I; Chiang, Y P
2013-11-01
A gait measurement system is a useful tool for rehabilitation applications. Such a system is used to conduct gait experiments in large workplaces such as laboratories where gait measurement equipment can be permanently installed. However, a gait measurement system should be portable if it is to be used in clinics or community centers for aged people. In a portable gait measurement system, the workspace is limited and landmarks on a subject may not be visible to the cameras during experiments. Thus, we propose a virtual-marker function to obtain positions of unseen landmarks for maintaining data consistency. This work develops a portable clinical gait measurement system consisting of lightweight motion capture devices, force plates, and a walkway assembled from plywood boards. We evaluated the portable clinic gait system with 11 normal subjects in three consecutive days in a limited experimental space. Results of gait analysis based on the verification of within-day and between-day coefficients of multiple correlations show that the proposed portable gait system is reliable.
Enhanced data consistency of a portable gait measurement system
NASA Astrophysics Data System (ADS)
Lin, Hsien-I.; Chiang, Y. P.
2013-11-01
A gait measurement system is a useful tool for rehabilitation applications. Such a system is used to conduct gait experiments in large workplaces such as laboratories where gait measurement equipment can be permanently installed. However, a gait measurement system should be portable if it is to be used in clinics or community centers for aged people. In a portable gait measurement system, the workspace is limited and landmarks on a subject may not be visible to the cameras during experiments. Thus, we propose a virtual-marker function to obtain positions of unseen landmarks for maintaining data consistency. This work develops a portable clinical gait measurement system consisting of lightweight motion capture devices, force plates, and a walkway assembled from plywood boards. We evaluated the portable clinic gait system with 11 normal subjects in three consecutive days in a limited experimental space. Results of gait analysis based on the verification of within-day and between-day coefficients of multiple correlations show that the proposed portable gait system is reliable.
Human portable preconcentrator system
Linker, Kevin L.; Brusseau, Charles A.; Hannum, David W.; Puissant, James G.; Varley, Nathan R.
2003-08-12
A preconcentrator system and apparatus suited to human portable use wherein sample potentially containing a target chemical substance is drawn into a chamber and through a pervious screen. The screen is adapted to capture target chemicals and then, upon heating, to release those chemicals into the chamber. Chemicals captured and then released in this fashion are then carried to a portable chemical detection device such as a portable ion mobility spectrometer. In the preferred embodiment, the means for drawing sample into the chamber comprises a reversible fan which, when operated in reverse direction, creates a backpressure that facilitates evolution of captured target chemicals into the chamber when the screen is heated. The screen can be positioned directly in front of the detector prior to heating to improve detection capability.
30 CFR 57.22227 - Approved testing devices (I-A, I-B, I-C, II-A, II-B, III, IV, V-A, and V-B mines).
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Methane monitoring devices and portable, battery-powered, self-contained devices used for measuring methane, other gases, and contaminants in mine air shall be approved by MSHA under the applicable... shall not be used to test for methane except as supplementary devices. (2) Flame safety lamps shall not...
30 CFR 57.22227 - Approved testing devices (I-A, I-B, I-C, II-A, II-B, III, IV, V-A, and V-B mines).
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Methane monitoring devices and portable, battery-powered, self-contained devices used for measuring methane, other gases, and contaminants in mine air shall be approved by MSHA under the applicable... shall not be used to test for methane except as supplementary devices. (2) Flame safety lamps shall not...
30 CFR 57.22227 - Approved testing devices (I-A, I-B, I-C, II-A, II-B, III, IV, V-A, and V-B mines).
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Methane monitoring devices and portable, battery-powered, self-contained devices used for measuring methane, other gases, and contaminants in mine air shall be approved by MSHA under the applicable... shall not be used to test for methane except as supplementary devices. (2) Flame safety lamps shall not...
The Influence of Affordances on Learner Preferences in Mobile Language Learning
ERIC Educational Resources Information Center
Uther, Maria; Banks, Adrian
2015-01-01
This study investigates the influence of sensory and cognitive affordances on the usability of mobile devices for multimedia language learning applications. An audio-based learning application--the "Vowel Trainer" (audio-based speech app), developed by University College London was chosen, against a comparison, text and picture-based…
Conceptual Model Learning Objects and Design Recommendations for Small Screens
ERIC Educational Resources Information Center
Churchill, Daniel
2011-01-01
This article presents recommendations for the design of conceptual models for applications via handheld devices such as personal digital assistants and some mobile phones. The recommendations were developed over a number of years through experience that involves design of conceptual models, and applications of these multimedia representations with…
Multi-Media in USAF Pilot Training.
ERIC Educational Resources Information Center
Wood, Milton E.
The flight-line portion of flying training has traditionally required large amounts of airborne practice under an apprenticeship form of instruction. New developments in educational technology, from both a philosophical and device point of view, provide new opportunities to train airborne skills in a ground environment. Through the use of…
A Catalog of Architectural Tactics for Cyber-Foraging
2015-01-06
Grid Access for Mobile Devices. PhD thesis, University of Southampton, 2008. [12] S.-H. Hung, J.-P. Shieh, and C.-P. Lee. Migrating android applications...computing. International Journal of Interactive Multimedia and Artificial Intelligence, 1(7):6–15, 2012. [17] K. Kumar and Y.-H. Lu. Cloud computing
Career Education: [Junior High.
ERIC Educational Resources Information Center
Cortland-Madison Board of Cooperative Educational Services, Cortland, NY.
The eighth in a series of nine career education guides contains six unit plans for grades 7-9. In general each unit presents goals, objectives, measuring devices, activities, instructional materials or resources, careers appropriate to the unit, a multimedia bibliography, and a unit evaluation form for teachers. Part one is a science unit which…
Modelling and Simulation as a Recognizing Method in Education
ERIC Educational Resources Information Center
Stoffa, Veronika
2004-01-01
Computer animation-simulation models of complex processes and events, which are the method of instruction, can be an effective didactic device. Gaining deeper knowledge about objects modelled helps to plan simulation experiments oriented on processes and events researched. Animation experiments realized on multimedia computers can aid easier…
Music, Technology, and an Evolving Curriculum.
ERIC Educational Resources Information Center
Moore, Brian
1992-01-01
Mechanical examples of musical technology, like the Steinway piano, are well known and accepted. Use of computers and electronic technology is the next logical step in developing art of music. MIDI (Musical Instrument Digital Interface) is explained, along with digital devices (such as synthesizers, sequencers, music notation software, multimedia,…
A Template-Based Short Course Concept on Android Application Development
ERIC Educational Resources Information Center
Akopian, David; Melkonyan, Arsen; Golgani, Santosh C.; Yuen, Timothy T.; Saygin, Can
2013-01-01
Smartphones are a common accessory to provide rich user experience due to superior memory, advanced software-hardware support, fast processing, and multimedia capabilities. Responding to this trend, advanced engineering systems tend to integrate mobile devices with their solutions to facilitate usability. With many young students showing interest…
Mobile Learning: Geocaching to Learn about Energy Systems
ERIC Educational Resources Information Center
Rose, Mary Annette; Gosman, Derek; Shoemaker, Korbin
2014-01-01
The children of "Generation Z"--today's American teens--are digital natives (Prensky, 2001) who have come to expect high-speed Internet service, high-resolution multimedia, and instant communication using wireless mobile technology. Teen ownership of digital devices is at a new high according to national surveys. School…
ERIC Educational Resources Information Center
Li, Haiqing
2010-01-01
With rapid advancements in information and communication technologies, computer-mediated communication channels such as email, web, mobile smart-phones with SMS, social networking websites (Facebook), multimedia websites, and OEM devices provide users with multiple technology choices to seek information. However, no study has compared the…
Portable document format file showing the surface models of cadaver whole body.
Shin, Dong Sun; Chung, Min Suk; Park, Jin Seo; Park, Hyung Seon; Lee, Sangho; Moon, Young Lae; Jang, Hae Gwon
2012-08-01
In the Visible Korean project, 642 three-dimensional (3D) surface models have been built from the sectioned images of a male cadaver. It was recently discovered that popular PDF file enables users to approach the numerous surface models conveniently on Adobe Reader. Purpose of this study was to present a PDF file including systematized surface models of human body as the beneficial contents. To achieve the purpose, fitting software packages were employed in accordance with the procedures. Two-dimensional (2D) surface models including the original sectioned images were embedded into the 3D surface models. The surface models were categorized into systems and then groups. The adjusted surface models were inserted to a PDF file, where relevant multimedia data were added. The finalized PDF file containing comprehensive data of a whole body could be explored in varying manners. The PDF file, downloadable freely from the homepage (http://anatomy.co.kr), is expected to be used as a satisfactory self-learning tool of anatomy. Raw data of the surface models can be extracted from the PDF file and employed for various simulations for clinical practice. The technique to organize the surface models will be applied to manufacture of other PDF files containing various multimedia contents.
NASA Astrophysics Data System (ADS)
Watanuki, Keiichi; Kojima, Kazuyuki
The environment in which Japanese industry has achieved great respect is changing tremendously due to the globalization of world economies, while Asian countries are undergoing economic and technical development as well as benefiting from the advances in information technology. For example, in the design of custom-made casting products, a designer who lacks knowledge of casting may not be able to produce a good design. In order to obtain a good design and manufacturing result, it is necessary to equip the designer and manufacturer with a support system related to casting design, or a so-called knowledge transfer and creation system. This paper proposes a new virtual reality based knowledge acquisition and job training system for casting design, which is composed of the explicit and tacit knowledge transfer systems using synchronized multimedia and the knowledge internalization system using portable virtual environment. In our proposed system, the education content is displayed in the immersive virtual environment, whereby a trainee may experience work in the virtual site operation. Provided that the trainee has gained explicit and tacit knowledge of casting through the multimedia-based knowledge transfer system, the immersive virtual environment catalyzes the internalization of knowledge and also enables the trainee to gain tacit knowledge before undergoing on-the-job training at a real-time operation site.
ERIC Educational Resources Information Center
Lee, Victor R.; DuMont, Maneksha
2010-01-01
There is a great potential opportunity to use portable physical activity monitoring devices as data collection tools for educational purposes. Using one such device, we designed and implemented a weeklong workshop with high school students to test the utility of such technology. During that intervention, students performed data investigations of…
Code of Federal Regulations, 2013 CFR
2013-10-01
... or data storage). ESI devices and media include, but are not be limited to: (1) Computers (mainframe...) Personal data assistants (PDAs); (5) External data storage devices including portable devices (e.g., flash drive); and (6) Data storage media (magnetic, e.g., tape; optical, e.g., compact disc, microfilm, etc...
Code of Federal Regulations, 2014 CFR
2014-10-01
... or data storage). ESI devices and media include, but are not be limited to: (1) Computers (mainframe...) Personal data assistants (PDAs); (5) External data storage devices including portable devices (e.g., flash drive); and (6) Data storage media (magnetic, e.g., tape; optical, e.g., compact disc, microfilm, etc...
Prototyping and testing of a fully autonomous road construction beacon, the iCone.
DOT National Transportation Integrated Search
2010-04-01
A revolutionary portable traffic monitoring device is developed, extensively prototyped and thoroughly tested throughout the State of New York as well as several other states. The resulting device, trademarked as the iCone, simplifies the process o...
Using a computer controlled system, this ultrafiltration device automates the process of concentrating a water sample and can be operated in the field. The system was also designed to reduce human exposure to potentially contaminated water.
Mobile phone-based biosensing: An emerging "diagnostic and communication" technology.
Quesada-González, Daniel; Merkoçi, Arben
2017-06-15
In this review we discuss recent developments on the use of mobile phones and similar devices for biosensing applications in which diagnostics and communications are coupled. Owing to the capabilities of mobile phones (their cameras, connectivity, portability, etc.) and to advances in biosensing, the coupling of these two technologies is enabling portable and user-friendly analytical devices. Any user can now perform quick, robust and easy (bio)assays anywhere and at any time. Among the most widely reported of such devices are paper-based platforms. Herein we provide an overview of a broad range of biosensing possibilities, from optical to electrochemical measurements; explore the various reported designs for adapters; and consider future opportunities for this technology in fields such as health diagnostics, safety & security, and environment monitoring. Copyright © 2016 Elsevier B.V. All rights reserved.
[Design of Portable Spirometer Based on Internet of Things of Medicine].
He, Yichen; Yang, Bo; Xiong, Shiqi; Li, Qing
2018-02-08
A kind of portable device for detecting common lung function parameters is mentioned in this paper. Using the singlechip microcomputer as the master control block to collect and process the data from high-accuracy gas pressure sensor, through the way of parametric calibration and linear interpolation to test and calculate the Forced Vital Capacity (FVC), Peak Expiratory Flow (PEF), Forced Expiratory Volume in one second (FEV1), and FEV1/FVC. Meanwhile, the detected parameters can be uploaded to the intelligent mobile terminal through the wireless transmission module. The device is able to show expiratory volume-time curve and the final parameters clearly, the error of measurement is less than 5%. In addition, that device is small and convenient, not only is good for clinical application, but also can be used for family in a house.
Preliminary design of betavoltaic battery using Co-60 and Pm-147 with GaAs substrate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Waris, A., E-mail: awaris@fi.itb.ac.id; Basar, K.; Kusumawati, Y.
Battery is very important for the present daily life, especially for portable devices. The longer utilization time the better performance of battery. Betavoltaic battery is a device that converts energy from beta decays of radioactive nuclide into electric current. One of merits of the later battery is the life time that can be more than ten years without recharging. To develop the betavoltaic battery for energy source of portable devices we have performed a preliminary simulation design of betavoltaic battery using Pm-147 and Co-60 a beta emitter radionuclides with n-GaAs substrate. From the results we found that the combination ofmore » Pm-147 with n-GaAs substrate results in 9.0% of efficiency and higher output current compared to references.« less
NASA Astrophysics Data System (ADS)
Syarif, A. N.; Bangun, K.
2017-08-01
Zygomatic fractures are among the most common fractures to the facial skeleton. However, because no standard and reliable method of evaluation is available to assess postoperative patients, we often rely on photographs and subjective assessments. A portable mirror stand device (MiRS), which is a new method for the standardization of photography, was developed in our institution. Used with image analysis software, this device provides a new method for evaluating outcomes after the open reduction and internal fixation of zygomatic fractures. The portable mirror stand device was set up in our outpatient clinic at the Cleft Craniofacial Center at Cipto Mangunkusumo Hospital. Photographs of 11 postoperative patients were taken using the device, and they were analyzed both manually and using image analysis software (ImageJ 1.46) for symmetry. The two methods were then compared to assess the correlation and agreement of the results. The measurements taken using the manual method and the software-assisted method did not differ significantly, which indicated the good agreement between the two methods. The results of the symmetry achieved atour center were similar to other centers in the Asian region (ΔZy = 3.4±1.5 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.4 mm) compared with (ΔZy = 3.2±1.7 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.5 mm). The treatment of zygomatic fracture a tour center achieved good results. The portable mirror stand device assisted the image analysis software (ImageJ 1.46), which could be beneficial in assessing symmetry in postoperative zygomatic fracture patients.
ERIC Educational Resources Information Center
Lynch, Julianne; Redpath, Terri
2014-01-01
With the revolution that has taken place in the functionality and uptake of portable networked "smart" technologies, educators are looking to see what potential applications such technologies might have for school education. This article reports on a study on the use of portable personal computing devices in the early years of schooling.…
STS-41 MS Shepherd uses DTO 1206 portable computer on OV-103's middeck
1990-10-10
STS-41 Mission Specialist (MS) William M. Shepherd uses Detailed Test Objective (DTO) Space Station Cursor Control Device Evaluation MACINTOSH portable computer on the middeck of Discovery, Orbiter Vehicle (OV) 103. The computer is velcroed to forward lockers MF71C and MF71E. Surrounding Shepherd are checklists, the field sequential (FS) crew cabin camera, and a lighting fixture.
Lab-on-a-Chip Application Development-Portable Test System (LOCAD) Phase 2
2009-03-21
ISS018-E-041370 (21 March 2009) --- Astronaut Sandra Magnus, STS-119 mission specialist, prepares to work with the Lab-on-a-Chip Application Development-Portable Test System (LOCAD-PTS) experiment in the Destiny laboratory while Space Shuttle Discovery remains docked with the International Space Station. LOCAD-PTS is a handheld device for rapid detection of biological and chemical substances onboard the station.
ERIC Educational Resources Information Center
Niño, Ana
2015-01-01
With the widespread use of mobile phones and portable devices it is inevitable to think of Mobile Assisted Language Learning as a means of independent learning in Higher Education. Nowadays many learners are keen to explore the wide variety of applications available in their portable and always readily available mobile phones and tablets. The fact…
Compact portable diffraction moire interferometer
Deason, Vance A.; Ward, Michael B.
1989-01-01
A compact and portable moire interferometer used to determine surface deformations of an object. The improved interferometer is comprised of a laser beam, optical and fiber optics devices coupling the beam to one or more evanescent wave splitters, and collimating lenses directing the split beam at one or more specimen gratings. Observation means including film and video cameras may be used to view and record the resultant fringe patterns.
Provision of Ubiquitous Tourist Information in Public Transport Networks
García, Carmelo R.; Pérez, Ricardo; Alayón, Francisco; Quesada-Arencibia, Alexis; Padrón, Gabino
2012-01-01
This paper outlines an information system for tourists using collective public transport based on mobile devices with limited computation and wireless connection capacities. In this system, the mobile device collaborates with the vehicle infrastructure in order to provide the user with multimedia (visual and audio) information about his/her trip. The information delivered, adapted to the user preferences, is synchronized with the passage of vehicles through points of interest along the route, for example: bus stops, tourist sights, public service centres, etc.
Ferenchick, Gary; Solomon, David; Durning, Steven J
2010-01-01
Portable computers are widely used by medical trainees, but there is a lack of data on how these devices are used in clinical education programs. The objective is to define the current use of portable computing in internal medicine clerkships and to determine medicine clerkship directors' perceptions of the current value and future importance of portable computing. A 2006 national survey of institutional members of the Clerkship Directors in Internal Medicine. Eighty-three of 110 (75%) of institutional members responded. An institutional requirement for portable computing was reported by 32 schools (39%), whereas only 13 (16%) provided students with a portable computer. Between 10 and 31 institutions (12-37%) reported student use for patient care activities (i.e. order entry, writing patient notes) and only 2 to 4 institutions (2-5%) required such use. The majority of respondents (59-95%) reported portable computer use for educational activities (i.e., tracking patient problems, knowledge resource), however, only in 5 to 19 (6-23%) were such educational uses required. Fifty-six respondents (68%) reported that portable computer's "added value" for teaching and 61 (73%) reported that portable computers would be important in meeting clerkship objectives in the next 3 years. Of interest, even among the institutions requiring portable computers, only 50% recommended or required specific software. Portable computing is required at 39% of allopathic medical schools in the United States. However required portable computing for specific patient care or educational tasks is uncommon. In addition, guidance on specific software exists in only one half of school requiring portable computers, suggesting informal or unstructured uses of required portable computer's in the remaining half. The educational impact of formal institutional requirements for software versus informal "user-defined" applications is unknown.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gorman, A; Seabrook, G; Brakken, A
Purpose: Small surgical devices and needles are used in many surgical procedures. Conventionally, an x-ray film is taken to identify missing devices/needles if post procedure count is incorrect. There is no data to indicate smallest surgical devices/needles that can be identified with digital radiography (DR), and its optimized acquisition technique. Methods: In this study, the DR equipment used is a Canon RadPro mobile with CXDI-70c wireless DR plate, and the same DR plate on a fixed Siemens Multix unit. Small surgical devices and needles tested include Rubber Shod, Bulldog, Fogarty Hydrogrip, and needles with sizes 3-0 C-T1 through 8-0 BV175-6.more » They are imaged with PMMA block phantoms with thickness of 2–8 inch, and an abdomen phantom. Various DR techniques are used. Images are reviewed on the portable x-ray acquisition display, a clinical workstation, and a diagnostic workstation. Results: all small surgical devices and needles are visible in portable DR images with 2–8 inch of PMMA. However, when they are imaged with the abdomen phantom plus 2 inch of PMMA, needles smaller than 9.3 mm length can not be visualized at the optimized technique of 81 kV and 16 mAs. There is no significant difference in visualization with various techniques, or between mobile and fixed radiography unit. However, there is noticeable difference in visualizing the smallest needle on a diagnostic reading workstation compared to the acquisition display on a portable x-ray unit. Conclusion: DR images should be reviewed on a diagnostic reading workstation. Using optimized DR techniques, the smallest needle that can be identified on all phantom studies is 9.3 mm. Sample DR images of various small surgical devices/needles available on diagnostic workstation for comparison may improve their identification. Further in vivo study is needed to confirm the optimized digital radiography technique for identification of lost small surgical devices and needles.« less
Stoot, Lauren J.; Cairns, Nicholas A.; Cull, Felicia; Taylor, Jessica J.; Jeffrey, Jennifer D.; Morin, Félix; Mandelman, John W.; Clark, Timothy D.; Cooke, Steven J.
2014-01-01
Non-human vertebrate blood is commonly collected and assayed for a variety of applications, including veterinary diagnostics and physiological research. Small, often non-lethal samples enable the assessment and monitoring of the physiological state and health of the individual. Traditionally, studies that rely on blood physiology have focused on captive animals or, in studies conducted in remote settings, have required the preservation and transport of samples for later analysis. In either situation, large, laboratory-bound equipment and traditional assays and analytical protocols are required. The use of point-of-care (POC) devices to measure various secondary blood physiological parameters, such as metabolites, blood gases and ions, has become increasingly popular recently, due to immediate results and their portability, which allows the freedom to study organisms in the wild. Here, we review the current uses of POC devices and their applicability to basic and applied studies on a variety of non-domesticated species. We located 79 individual studies that focused on non-domesticated vertebrates, including validation and application of POC tools. Studies focused on a wide spectrum of taxa, including mammals, birds and herptiles, although the majority of studies focused on fish, and typical variables measured included blood glucose, lactate and pH. We found that calibrations for species-specific blood physiology values are necessary, because ranges can vary within and among taxa and are sometimes outside the measurable range of the devices. In addition, although POC devices are portable and robust, most require durable cases, they are seldom waterproof/water-resistant, and factors such as humidity and temperature can affect the performance of the device. Overall, most studies concluded that POC devices are suitable alternatives to traditional laboratory devices and eliminate the need for transport of samples; however, there is a need for greater emphasis on rigorous calibration and validation of these units and appreciation of their limitations. PMID:27293632
Advances in the in Vivo Raman Spectroscopy of Malignant Skin Tumors Using Portable Instrumentation
Kourkoumelis, Nikolaos; Balatsoukas, Ioannis; Moulia, Violetta; Elka, Aspasia; Gaitanis, Georgios; Bassukas, Ioannis D.
2015-01-01
Raman spectroscopy has emerged as a promising tool for real-time clinical diagnosis of malignant skin tumors offering a number of potential advantages: it is non-intrusive, it requires no sample preparation, and it features high chemical specificity with minimal water interference. However, in vivo tissue evaluation and accurate histopathological classification remain a challenging task for the successful transition from laboratory prototypes to clinical devices. In the literature, there are numerous reports on the applications of Raman spectroscopy to biomedical research and cancer diagnostics. Nevertheless, cases where real-time, portable instrumentations have been employed for the in vivo evaluation of skin lesions are scarce, despite their advantages in use as medical devices in the clinical setting. This paper reviews the advances in real-time Raman spectroscopy for the in vivo characterization of common skin lesions. The translational momentum of Raman spectroscopy towards the clinical practice is revealed by (i) assembling the technical specifications of portable systems and (ii) analyzing the spectral characteristics of in vivo measurements. PMID:26132563
Meng, Xin; Huang, Huachuan; Yan, Keding; Tian, Xiaolin; Yu, Wei; Cui, Haoyang; Kong, Yan; Xue, Liang; Liu, Cheng; Wang, Shouyu
2016-12-20
In order to realize high contrast imaging with portable devices for potential mobile healthcare, we demonstrate a hand-held smartphone based quantitative phase microscope using the transport of intensity equation method. With a cost-effective illumination source and compact microscope system, multi-focal images of samples can be captured by the smartphone's camera via manual focusing. Phase retrieval is performed using a self-developed Android application, which calculates sample phases from multi-plane intensities via solving the Poisson equation. We test the portable microscope using a random phase plate with known phases, and to further demonstrate its performance, a red blood cell smear, a Pap smear and monocot root and broad bean epidermis sections are also successfully imaged. Considering its advantages as an accurate, high-contrast, cost-effective and field-portable device, the smartphone based hand-held quantitative phase microscope is a promising tool which can be adopted in the future in remote healthcare and medical diagnosis.
Phillips, Reid H; Jain, Rahil; Browning, Yoni; Shah, Rachana; Kauffman, Peter; Dinh, Doan; Lutz, Barry R
2016-08-16
Fluid control remains a challenge in development of portable lab-on-a-chip devices. Here, we show that microfluidic networks driven by single-frequency audio tones create resonant oscillating flow that is predicted by equivalent electrical circuit models. We fabricated microfluidic devices with fluidic resistors (R), inductors (L), and capacitors (C) to create RLC networks with band-pass resonance in the audible frequency range available on portable audio devices. Microfluidic devices were fabricated from laser-cut adhesive plastic, and a "buzzer" was glued to a diaphragm (capacitor) to integrate the actuator on the device. The AC flowrate magnitude was measured by imaging oscillation of bead tracers to allow direct comparison to the RLC circuit model across the frequency range. We present a systematic build-up from single-channel systems to multi-channel (3-channel) networks, and show that RLC circuit models predict complex frequency-dependent interactions within multi-channel networks. Finally, we show that adding flow rectifying valves to the network creates pumps that can be driven by amplified and non-amplified audio tones from common audio devices (iPod and iPhone). This work shows that RLC circuit models predict resonant flow responses in multi-channel fluidic networks as a step towards microfluidic devices controlled by audio tones.
Home oxygen therapy: re-thinking the role of devices.
Melani, Andrea S; Sestini, Piersante; Rottoli, Paola
2018-03-01
A range of devices are available for delivering and monitoring home oxygen therapy (HOT). Guidelines do not give indications for the choice of the delivery device but recommend the use of an ambulatory system in subjects on HOT whilst walking. Areas covered: We provide a clinical overview of HOT and review traditional and newer delivery and monitoring devices for HOT. Despite relevant technology advancements, clinicians, faced with many challenges when they prescribe oxygen therapy, often remain familiar to traditional devices and continuous flow delivery of oxygen. Some self-filling delivery-less devices could increase the users' level of independence with ecological advantage and, perhaps, reduced cost. Some newer portable oxygen concentrators are being available, but more work is needed to understand their performances in different diseases and clinical settings. Pulse oximetry has gained large diffusion worldwide and some models permit long-term monitoring. Some closed-loop portable monitoring devices are also able to adjust oxygen flow automatically in accordance with the different needs of everyday life. This might help to improve adherence and the practice of proper oxygen titration that has often been omitted because difficult to perform and time-consuming. Expert commentary: The prescribing physicians should know the characteristics of newer devices and use technological advancements to improve the practice of HOT.
46 CFR 98.30-3 - Vessels carrying MPTs.
Code of Federal Regulations, 2013 CFR
2013-10-01
... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS SPECIAL CONSTRUCTION, ARRANGEMENT, AND OTHER PROVISIONS FOR CERTAIN DANGEROUS CARGOES IN BULK Portable Tanks § 98.30-3... corrosion-resistant tag— (a) An inspection date for pressure relief devices and vacuum relief devices in...
Mak, Yim Wah; Wu, Cynthia Sau Ting; Hui, Donna Wing Shun; Lam, Siu Ping; Tse, Hei Yin; Yu, Wing Yan; Wong, Ho Ting
2014-01-01
Screen viewing is considered to have adverse impacts on the sleep of adolescents. Although there has been a considerable amount of research on the association between screen viewing and sleep, most studies have focused on specific types of screen viewing devices such as televisions and computers. The present study investigated the duration with which currently prevalent screen viewing devices (including televisions, personal computers, mobile phones, and portable video devices) are viewed in relation to sleep duration, sleep quality, and daytime sleepiness among Hong Kong adolescents (N = 762). Television and computer viewing remain prevalent, but were not correlated with sleep variables. Mobile phone viewing was correlated with all sleep variables, while portable video device viewing was shown to be correlated only with daytime sleepiness. The results demonstrated a trend of increase in the prevalence and types of screen viewing and their effects on the sleep patterns of adolescents. PMID:25353062
Flexible, highly efficient all-polymer solar cells
Kim, Taesu; Kim, Jae-Han; Kang, Tae Eui; Lee, Changyeon; Kang, Hyunbum; Shin, Minkwan; Wang, Cheng; Ma, Biwu; Jeong, Unyong; Kim, Taek-Soo; Kim, Bumjoon J.
2015-01-01
All-polymer solar cells have shown great potential as flexible and portable power generators. These devices should offer good mechanical endurance with high power-conversion efficiency for viability in commercial applications. In this work, we develop highly efficient and mechanically robust all-polymer solar cells that are based on the PBDTTTPD polymer donor and the P(NDI2HD-T) polymer acceptor. These systems exhibit high power-conversion efficiency of 6.64%. Also, the proposed all-polymer solar cells have even better performance than the control polymer-fullerene devices with phenyl-C61-butyric acid methyl ester (PCBM) as the electron acceptor (6.12%). More importantly, our all-polymer solar cells exhibit dramatically enhanced strength and flexibility compared with polymer/PCBM devices, with 60- and 470-fold improvements in elongation at break and toughness, respectively. The superior mechanical properties of all-polymer solar cells afford greater tolerance to severe deformations than conventional polymer-fullerene solar cells, making them much better candidates for applications in flexible and portable devices. PMID:26449658
Detection and Localization of Money Bills Concealed Behind Wooden Walls Using Compton Scattering
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wart, Jason A. van; Hussein, Esam M.A.; Waller, Edward J
2005-05-15
This work presents a portable device for detecting visually obscured contraband money bills that may be hidden within conventional household walls for the purpose of avoiding confiscation. The device utilizes the Compton backscattering of photons emitted from a collimated {sup 241}Am source. The scattered photons are detected with a thin NaI(Tl) detector, either over a wide field of view for surface scanning of the wall or within a confined view field for depth scanning. The design of the device was optimized for best density contrast and highest count rate for a given source activity. It was shown that the minimummore » detectable amount of contraband, with >95% confidence level, is 86 paper bills. The contraband was detectable when hidden in household walls made of gyprock or wooden paneling, even when masked by higher density materials such as metallic piping. The device's capability exceeded those of commercially available density-based portable contraband detectors.« less
NASA Astrophysics Data System (ADS)
Asilah Khairi, Nor; Bahari Jambek, Asral
2017-11-01
An Internet of Things (IoT) device is usually powered by a small battery, which does not last long. As a result, saving energy in IoT devices has become an important issue when it comes to this subject. Since power consumption is the primary cause of radio communication, some researchers have proposed several compression algorithms with the purpose of overcoming this particular problem. Several data compression algorithms from previous reference papers are discussed in this paper. The description of the compression algorithm in the reference papers was collected and summarized in a table form. From the analysis, MAS compression algorithm was selected as a project prototype due to its high potential for meeting the project requirements. Besides that, it also produced better performance regarding energy-saving, better memory usage, and data transmission efficiency. This method is also suitable to be implemented in WSN. MAS compression algorithm will be prototyped and applied in portable electronic devices for Internet of Things applications.
Portable rotating discharge plasma device
NASA Astrophysics Data System (ADS)
Dwyer, B. L.; Brooks, N. H.; Lee, R. L.
2011-10-01
We constructed two devices for the purpose of educational demonstration: a rotating tube containing media of two densities to demonstrate axial confinement and a similar device that uses pressure variation to convert a long plasma glow discharge into a long straight arc. In the first device, the buoyant force is countered by the centripetal force, which confines less dense materials to the center of the column. Similarly, a plasma arc heats the gas through which it passes, creating a hot gaseous bubble that is less dense than the surrounding medium. Rotating its containment envelope stabilizes this gas bubble in an analogous manner to an air bubble in a rotating tube of water. In addition to stabilization, the rotating discharge also exhibits a decrease in buoyancy-driven convection currents. This limits the power loss to the walls, which decreases the field strength requirement for maintaining the arc. These devices demonstrate principles of electrodynamics, plasma physics, and fluid mechanics. They are portable and safe for classroom use. Work supported by US DOE under DE-FC02-04ER54698 and the National Undergraduate Fellowship in Fusion Science and Engineering.
Portable Intravenous Fluid Production Device for Ground Use
NASA Technical Reports Server (NTRS)
Scarpa, Philip J.; Scheuer, Wolfgang K.
2012-01-01
There are several medical conditions that require intravenous (IV) fluids. Limitations of mass, volume, storage space, shelf-life, transportation, and local resources can restrict the availability of such important fluids. These limitations are expected in long-duration space exploration missions and in remote or austere environments on Earth. Current IV fluid production requires large factory-based processes. Easy, portable, on-site production of IV fluids can eliminate these limitations. Based on experience gained in developing a device for spaceflight, a ground-use device was developed. This design uses regular drinking water that is pumped through two filters to produce, in minutes, sterile, ultrapure water that meets the stringent quality standards of the United States Pharmacopeia for Water for Injection (Total Bacteria, Conductivity, Endotoxins, Total Organic Carbon). The device weighs 2.2 lb (1 kg) and is 10 in. long, 5 in. wide, and 3 in. high (.25, 13, and 7.5 cm, respectively) in its storage configuration. This handheld device produces one liter of medical-grade water in 21 minutes. Total production capacity for this innovation is expected to be in the hundreds of liters.
Podcasting: contemporary patient education.
Abreu, Daniel V; Tamura, Thomas K; Sipp, J Andrew; Keamy, Donald G; Eavey, Roland D
2008-04-01
Portable video technology is a widely available new tool with potential to be used by pediatric otolaryngology practices for patient and family education. Podcasts are media broadcasts that employ this new technology. They can be accessed via the Internet and viewed either on a personal computer or on a handheld device, such as an iPod or an MP3 player. We wished to examine the feasibility of establishing a podcast-hosting Web site. We digitally recorded pediatric otologic procedures in the operating room and saved the digital files to DVDs. We then edited the DVDs at home with video-editing software on a personal computer. Next, spoken narrative was recorded with audio-recording software and combined with the edited video clips. The final products were converted into the M4V file format, and the final versions were uploaded onto our hospital's Web site. We then downloaded the podcasts onto a high-quality portable media player so that we could evaluate their quality. All of the podcasts are now on the hospital Web site, where they can be downloaded by patients and families at no cost. The site includes instructions on how to download the appropriate free software for viewing the podcasts on a portable media player or on a computer. Using this technology for patient education expands the audience and permits portability of information. We conclude that a home computer can be used to inexpensively create informative surgery demonstrations that can be accessed via a Web site and transferred to portable viewing devices with excellent quality.
A portable CW/FM-CW Doppler radar for local investigation of severe storms
NASA Astrophysics Data System (ADS)
Unruh, Wesley P.; Wolf, Michael A.; Bluestein, Howard B.
During the 1987 spring storm season we used a portable 1-W X-band CW Doppler radar to probe a tornado, a funnel cloud, and a wall cloud in Oklahoma and Texas. This same device was used during the spring storm season in 1988 to probe a wall cloud in Texas. The radar was battery powered and highly portable, and thus convenient to deploy from our chase vehicle. The device separated the receding and approaching Doppler velocities in real time and, while the radar was being used, it allowed convenient stereo data recording for later spectral analysis and operator monitoring of the Doppler signals in stereo headphones. This aural monitoring, coupled with the ease with which an operator can be trained to recognize the nature of the signals heard, made the radar very easy to operate reliably and significantly enhanced the quality of the data being recorded. At the end of the 1988 spring season, the radar was modified to include FM-CW ranging and processing. These modifications were based on a unique combination of video recording and FM chirp generation, which incorporated a video camera and recorder as an integral part of the radar. After modification, the radar retains its convenient portability and the operational advantage of being able to listen to the Doppler signals directly. The original mechanical design was unaffected by these additions. During the summer of 1988, this modified device was used at the Langmuir Laboratory at Socorro, New Mexico in an attempt to measure vertical convective flow in a thunderstorm.
A portable blood plasma clot micro-elastometry device based on resonant acoustic spectroscopy
NASA Astrophysics Data System (ADS)
Krebs, C. R.; Li, Ling; Wolberg, Alisa S.; Oldenburg, Amy L.
2015-07-01
Abnormal blood clot stiffness is an important indicator of coagulation disorders arising from a variety of cardiovascular diseases and drug treatments. Here, we present a portable instrument for elastometry of microliter volume blood samples based upon the principle of resonant acoustic spectroscopy, where a sample of well-defined dimensions exhibits a fundamental longitudinal resonance mode proportional to the square root of the Young's modulus. In contrast to commercial thromboelastography, the resonant acoustic method offers improved repeatability and accuracy due to the high signal-to-noise ratio of the resonant vibration. We review the measurement principles and the design of a magnetically actuated microbead force transducer applying between 23 pN and 6.7 nN, providing a wide dynamic range of elastic moduli (3 Pa-27 kPa) appropriate for measurement of clot elastic modulus (CEM). An automated and portable device, the CEMport, is introduced and implemented using a 2 nm resolution displacement sensor with demonstrated accuracy and precision of 3% and 2%, respectively, of CEM in biogels. Importantly, the small strains (<0.13%) and low strain rates (<1/s) employed by the CEMport maintain a linear stress-to-strain relationship which provides a perturbative measurement of the Young's modulus. Measurements of blood plasma CEM versus heparin concentration show that CEMport is sensitive to heparin levels below 0.050 U/ml, which suggests future applications in sensing heparin levels of post-surgical cardiopulmonary bypass patients. The portability, high accuracy, and high precision of this device enable new clinical and animal studies for associating CEM with blood coagulation disorders, potentially leading to improved diagnostics and therapeutic monitoring.