Sample records for portable vibrating tools

  1. The Effect of a Mechanical Arm System on Portable Grinder Vibration Emissions.

    PubMed

    McDowell, Thomas W; Welcome, Daniel E; Warren, Christopher; Xu, Xueyan S; Dong, Ren G

    2016-04-01

    Mechanical arm systems are commonly used to support powered hand tools to alleviate ergonomic stressors related to the development of workplace musculoskeletal disorders. However, the use of these systems can increase exposure times to other potentially harmful agents such as hand-transmitted vibration. To examine how these tool support systems affect tool vibration, the primary objectives of this study were to characterize the vibration emissions of typical portable pneumatic grinders used for surface grinding with and without a mechanical arm support system at a workplace and to estimate the potential risk of the increased vibration exposure time afforded by the use of these mechanical arm systems. This study also developed a laboratory-based simulated grinding task based on the ISO 28927-1 (2009) standard for assessing grinder vibrations; the simulated grinding vibrations were compared with those measured during actual workplace grinder operations. The results of this study demonstrate that use of the mechanical arm may provide a health benefit by reducing the forces required to lift and maneuver the tools and by decreasing hand-transmitted vibration exposure. However, the arm does not substantially change the basic characteristics of grinder vibration spectra. The mechanical arm reduced the average frequency-weighted acceleration by about 24% in the workplace and by about 7% in the laboratory. Because use of the mechanical arm system can increase daily time-on-task by 50% or more, the use of such systems may actually increase daily time-weighted hand-transmitted vibration exposures in some cases. The laboratory acceleration measurements were substantially lower than the workplace measurements, and the laboratory tool rankings based on acceleration were considerably different than those from the workplace. Thus, it is doubtful that ISO 28927-1 is useful for estimating workplace grinder vibration exposures or for predicting workplace grinder acceleration rank orders. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2015.

  2. The Effect of a Mechanical Arm System on Portable Grinder Vibration Emissions

    PubMed Central

    McDowell, Thomas W.; Welcome, Daniel E.; Warren, Christopher; Xu, Xueyan S.; Dong, Ren G.

    2016-01-01

    Mechanical arm systems are commonly used to support powered hand tools to alleviate ergonomic stressors related to the development of workplace musculoskeletal disorders. However, the use of these systems can increase exposure times to other potentially harmful agents such as hand-transmitted vibration. To examine how these tool support systems affect tool vibration, the primary objectives of this study were to characterize the vibration emissions of typical portable pneumatic grinders used for surface grinding with and without a mechanical arm support system at a workplace and to estimate the potential risk of the increased vibration exposure time afforded by the use of these mechanical arm systems. This study also developed a laboratory-based simulated grinding task based on the ISO 28927-1 (2009) standard for assessing grinder vibrations; the simulated grinding vibrations were compared with those measured during actual workplace grinder operations. The results of this study demonstrate that use of the mechanical arm may provide a health benefit by reducing the forces required to lift and maneuver the tools and by decreasing hand-transmitted vibration exposure. However, the arm does not substantially change the basic characteristics of grinder vibration spectra. The mechanical arm reduced the average frequency-weighted acceleration by about 24% in the workplace and by about 7% in the laboratory. Because use of the mechanical arm system can increase daily time-on-task by 50% or more, the use of such systems may actually increase daily time-weighted hand-transmitted vibration exposures in some cases. The laboratory acceleration measurements were substantially lower than the workplace measurements, and the laboratory tool rankings based on acceleration were considerably different than those from the workplace. Thus, it is doubtful that ISO 28927-1 is useful for estimating workplace grinder vibration exposures or for predicting workplace grinder acceleration rank orders. PMID:26628522

  3. Evaluation of protective gloves and working techniques for reducing hand-arm vibration exposure in the workplace.

    PubMed

    Milosevic, Matija; McConville, Kristiina M Valter

    2012-01-01

    Operation of handheld power tools results in exposure to hand-arm vibrations, which over time lead to numerous health complications. The objective of this study was to evaluate protective equipment and working techniques for the reduction of vibration exposure. Vibration transmissions were recorded during different work techniques: with one- and two-handed grip, while wearing protective gloves (standard, air and anti-vibration gloves) and while holding a foam-covered tool handle. The effect was examined by analyzing the reduction of transmitted vibrations at the wrist. The vibration transmission was recorded with a portable device using a triaxial accelerometer. The results suggest large and significant reductions of vibration with appropriate safety equipment. Reductions of 85.6% were achieved when anti-vibration gloves were used. Our results indicated that transmitted vibrations were affected by several factors and could be measured and significantly reduced.

  4. On the spot damage detection methodology for highway bridges during natural crises : tech transfer summary.

    DOT National Transportation Integrated Search

    2010-07-01

    The objective of this work was to develop a : low-cost portable damage detection tool to : assess and predict damage areas in highway : bridges. : The proposed tool was based on standard : vibration-based damage identification (VBDI) : techniques but...

  5. The qualitative assessment of pneumatic actuators operation in terms of vibration criteria

    NASA Astrophysics Data System (ADS)

    Hetmanczyk, M. P.; Michalski, P.

    2015-11-01

    The work quality of pneumatic actuators can be assessed in terms of multiple criteria. In the case of complex systems with pneumatic actuators retained at end positions (with occurrence of piston impact in cylinder covers) the vibration criteria constitute the most reliable indicators. The paper presents an impact assessment on the operating condition of the rodless pneumatic cylinder regarding to selected vibrational symptoms. On the basis of performed analysis the authors had shown meaningful premises allowing an evaluation of the performance and tuning of end position damping piston movement with usage the most common diagnostic tools (portable vibration analyzers). The presented method is useful in tuning of parameters in industrial conditions.

  6. Sensitization of a stray-field NMR to vibrations: a potential for MR elastometry with a portable NMR sensor.

    PubMed

    Mastikhin, Igor; Barnhill, Marie

    2014-11-01

    An NMR signal from a sample in a constant stray field of a portable NMR sensor is sensitized to vibrations. The CPMG sequence is synchronized to vibrations so that the constant gradient becomes an "effective" square-wave gradient, leading to the vibration-induced phase accumulation. The integrating nature of the spot measurement, combined with the phase distribution due to a non-uniform gradient and/or a wave field, leads to a destructive interference, the drop in the signal intensity and changes in the echo train shape. Vibrations with amplitudes as small as 140 nm were reliably detected with the permanent gradient of 12.4 T/m. The signal intensity depends on the phase offset between the vibrations and the pulse sequence. This approach opens the way for performing elastometry and micro-rheology measurements with portable NMR devices beyond the walls of a laboratory. Even without synchronization, if a vibration frequency is comparable to 1/2TE of the CPMG sequence, the signal can be severely affected, making it important for potential industrial applications of stray-field NMR. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Prevention, clinical, and pathophysiological research on vibration syndrome.

    PubMed

    Yamada, S; Sakakibara, H; Harada, N; Matsumoto, T

    1993-11-01

    In the 1950s, introduction of portable power tools into the production process of many industries began on a large scale around the world and resulted in many cases of occupational vibration syndrome after the 1960s. There was an urgent need to undertake preventive steps, medical assessment and therapy throughout the world. At the end of 1964, our investigation began in Japanese national forests, and then in mining and stone quarries. Our research and efforts resulted in a comprehensive system for prevention of vibration syndrome in the Japanese national forest industry. It has presented a good model of prevention for other industries in Japan. Clinical and pathophysiological research on vibration syndrome in the 1960s and 1970s clarified disturbances of the peripheral circulatory, nervous, and musculoskeletal systems. From the mid-1970s, neurophysiological, neurochemical, and clinical research on vibration syndrome in relation to the autonomic nervous system developed. Our studies contributed to the advancement of research in this field. More in-depth study is needed to determine the role of the autonomic nervous system in vibration syndrome.

  8. A Portable Gait Asymmetry Rehabilitation System for Individuals with Stroke Using a Vibrotactile Feedback.

    PubMed

    Afzal, Muhammad Raheel; Oh, Min-Kyun; Lee, Chang-Hee; Park, Young Sook; Yoon, Jungwon

    2015-01-01

    Gait asymmetry caused by hemiparesis results in reduced gait efficiency and reduced activity levels. In this paper, a portable rehabilitation device is proposed that can serve as a tool in diagnosing gait abnormalities in individuals with stroke and has the capability of providing vibration feedback to help compensate for the asymmetric gait. Force-sensitive resistor (FSR) based insoles are used to detect ground contact and estimate stance time. A controller (Arduino) provides different vibration feedback based on the gait phase measurement. It also allows wireless interaction with a personal computer (PC) workstation using the XBee transceiver module, featuring data logging capabilities for subsequent analysis. Walking trials conducted with healthy young subjects allowed us to observe that the system can influence abnormality in the gait. The results of trials showed that a vibration cue based on temporal information was more effective than intensity information. With clinical experiments conducted for individuals with stroke, significant improvement in gait symmetry was observed with minimal disturbance caused to the balance and gait speed as an effect of the biofeedback. Future studies of the long-term rehabilitation effects of the proposed system and further improvements to the system will result in an inexpensive, easy-to-use, and effective rehabilitation device.

  9. A Portable Gait Asymmetry Rehabilitation System for Individuals with Stroke Using a Vibrotactile Feedback

    PubMed Central

    Afzal, Muhammad Raheel; Oh, Min-Kyun; Lee, Chang-Hee; Park, Young Sook; Yoon, Jungwon

    2015-01-01

    Gait asymmetry caused by hemiparesis results in reduced gait efficiency and reduced activity levels. In this paper, a portable rehabilitation device is proposed that can serve as a tool in diagnosing gait abnormalities in individuals with stroke and has the capability of providing vibration feedback to help compensate for the asymmetric gait. Force-sensitive resistor (FSR) based insoles are used to detect ground contact and estimate stance time. A controller (Arduino) provides different vibration feedback based on the gait phase measurement. It also allows wireless interaction with a personal computer (PC) workstation using the XBee transceiver module, featuring data logging capabilities for subsequent analysis. Walking trials conducted with healthy young subjects allowed us to observe that the system can influence abnormality in the gait. The results of trials showed that a vibration cue based on temporal information was more effective than intensity information. With clinical experiments conducted for individuals with stroke, significant improvement in gait symmetry was observed with minimal disturbance caused to the balance and gait speed as an effect of the biofeedback. Future studies of the long-term rehabilitation effects of the proposed system and further improvements to the system will result in an inexpensive, easy-to-use, and effective rehabilitation device. PMID:26161398

  10. A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment

    PubMed Central

    de ANDRADE, Pâmela Cândida Aires Ribas; LUTHI, Leonardo Flores; STANLEY, Kyle; CARDOSO, Antônio Carlos

    2012-01-01

    Objective The aim of this study was to test a new portable vibrator for plaster pouring (developed for this purpose), comparing the effect of its use on the accuracy of working cast of implant-supported restorations to the conventional vibrator. Material and methods From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: Group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), Group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and Group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05). Results Means±standard deviations were as follows: GI: 19.19±4.73 µm; GII: 21.72±5.41 µm; GIII: 13.5±2.39 µm (P<0.05), with GIII significantly lower as compared to the other groups. Conclusion Within the limitations of this study, it was concluded that a greater accuracy of working cast was achieved when a portable vibrator was used for casting molds. PMID:23138736

  11. Portable vibration exciter

    NASA Technical Reports Server (NTRS)

    Beecher, L. C.; Williams, F. T.

    1970-01-01

    Gas-driven vibration exciter produces a sinusoidal excitation function controllable in frequency and in amplitude. It allows direct vibration testing of components under normal loads, removing the possibility of component damage due to high static pressure.

  12. Parasites under the Spotlight: Applications of Vibrational Spectroscopy to Malaria Research.

    PubMed

    Perez-Guaita, David; Marzec, Katarzyna M; Hudson, Andrew; Evans, Corey; Chernenko, Tatyana; Matthäus, Christian; Miljkovic, Milos; Diem, Max; Heraud, Philip; Richards, Jack S; Andrew, Dean; Anderson, David A; Doerig, Christian; Garcia-Bustos, Jose; McNaughton, Don; Wood, Bayden R

    2018-04-20

    New technologies to diagnose malaria at high sensitivity and specificity are urgently needed in the developing world where the disease continues to pose a huge burden on society. Infrared and Raman spectroscopy-based diagnostic methods have a number of advantages compared with other diagnostic tests currently on the market. These include high sensitivity and specificity for detecting low levels of parasitemia along with ease of use and portability. Here, we review the application of vibrational spectroscopic techniques for monitoring and detecting malaria infection. We discuss the role of vibrational (infrared and Raman) spectroscopy in understanding the processes of parasite biology and its application to the study of interactions with antimalarial drugs. The distinct molecular phenotype that characterizes malaria infection and the high sensitivity enabling detection of low parasite densities provides a genuine opportunity for vibrational spectroscopy to become a front-line tool in the elimination of this deadly disease and provide molecular insights into the chemistry of this unique organism.

  13. Combined effect of noise and vibration on passenger acceptance

    NASA Technical Reports Server (NTRS)

    Leatherwood, J. D.

    1984-01-01

    An extensive research program conducted at NASA Langley Research Center to develop a comprehensive model of passenger comfort response to combined noise and vibration environments has been completed. This model was developed for use in the prediction and/or assessment of vehicle ride quality and as a ride quality design tool. The model has the unique capability to transform individual elements of vehicle interior noise and vibration into subjective units and combining the subjective units to produce a total subjective discomfort index as well as the other useful subjective indices. This paper summarizes the basic approach used in the development of the NASA ride comfort model, presents some of the more fundamental results obtained, describes several application of the model to operational vehicles, and discusses a portable, self-contained ride quality meter system that is a direct hardware/software implementation of the NASA comfort algorithm.

  14. Time-Varying Vocal Folds Vibration Detection Using a 24 GHz Portable Auditory Radar

    PubMed Central

    Hong, Hong; Zhao, Heng; Peng, Zhengyu; Li, Hui; Gu, Chen; Li, Changzhi; Zhu, Xiaohua

    2016-01-01

    Time-varying vocal folds vibration information is of crucial importance in speech processing, and the traditional devices to acquire speech signals are easily smeared by the high background noise and voice interference. In this paper, we present a non-acoustic way to capture the human vocal folds vibration using a 24-GHz portable auditory radar. Since the vocal folds vibration only reaches several millimeters, the high operating frequency and the 4 × 4 array antennas are applied to achieve the high sensitivity. The Variational Mode Decomposition (VMD) based algorithm is proposed to decompose the radar-detected auditory signal into a sequence of intrinsic modes firstly, and then, extract the time-varying vocal folds vibration frequency from the corresponding mode. Feasibility demonstration, evaluation, and comparison are conducted with tonal and non-tonal languages, and the low relative errors show a high consistency between the radar-detected auditory time-varying vocal folds vibration and acoustic fundamental frequency, except that the auditory radar significantly improves the frequency-resolving power. PMID:27483261

  15. Time-Varying Vocal Folds Vibration Detection Using a 24 GHz Portable Auditory Radar.

    PubMed

    Hong, Hong; Zhao, Heng; Peng, Zhengyu; Li, Hui; Gu, Chen; Li, Changzhi; Zhu, Xiaohua

    2016-07-28

    Time-varying vocal folds vibration information is of crucial importance in speech processing, and the traditional devices to acquire speech signals are easily smeared by the high background noise and voice interference. In this paper, we present a non-acoustic way to capture the human vocal folds vibration using a 24-GHz portable auditory radar. Since the vocal folds vibration only reaches several millimeters, the high operating frequency and the 4 × 4 array antennas are applied to achieve the high sensitivity. The Variational Mode Decomposition (VMD) based algorithm is proposed to decompose the radar-detected auditory signal into a sequence of intrinsic modes firstly, and then, extract the time-varying vocal folds vibration frequency from the corresponding mode. Feasibility demonstration, evaluation, and comparison are conducted with tonal and non-tonal languages, and the low relative errors show a high consistency between the radar-detected auditory time-varying vocal folds vibration and acoustic fundamental frequency, except that the auditory radar significantly improves the frequency-resolving power.

  16. A Boon for Bone Research

    NASA Technical Reports Server (NTRS)

    1996-01-01

    NASA studies for astronaut health in long-term space missions led to the development of the Mechanical Response Tissue Analyzer (MRTA), a research tool for astronaut disuse, osteoporosis and related bone disorders among the general population. Ames Research Center and Stanford University generated a workable device and with Gait Scan, Inc., refined and commercialized it. The MRTA is a portable dsinstrument that measures the bending stiffness of bones using electrically-induced vibration and detects and analyzes the frequencies of the resonating bone. Unlike some other methods, the MRTA uses no radiation and is fast, simple and relatively inexpensive.

  17. A military grade, field usable, Raman analyzer: measurement of captured fuel

    NASA Astrophysics Data System (ADS)

    Farquharson, Stuart; Smith, Wayne; Shende, Chetan; Patient, Michael; Huang, Hermes; Brouillette, Carl

    2014-05-01

    Portable Raman analyzers have emerged during the first part of this century as an important field tool for crime scene and forensic analysis, primarily for their ability to identify unknown substances. This ability is also important to the US military, which has been investigating such analyzers for identification of explosive materials that may be used to produce improvised explosive devices, chemicals that may be used to produce chemical warfare agents, and fuels in storage tanks that may be used to power US military vehicles. However, the use of such portable analyzers requires that they meet stringent military standards (specifically MIL-STD 810G). These requirements include among others: 1) light weight and small size (< 35 pounds, < 3 cu. ft.), 2) vibration and shock resistant (26 four foot drops), 3) operation from -4 to 110 oF, 4) operation in blowing dust, sand and rain, 5) battery operation, and of course 6) safe operation (no laser or shock hazards). Here we describe a portable Raman analyzer that meets all of these requirements, and its use to determine if captured fuels are suitable for use.

  18. National regulations for diagnostics in health surveillance, therapy and compensation of hand-transmitted vibration injury in Japan.

    PubMed

    Yamada, Shin'ya

    2002-01-01

    During the period of technological innovation and rapid economic development, portable power tools were introduced on a large scale in Japan. Vibration disease from the operation of those tools and its prevention and therapy became urgent social problems in the 1970s. This paper aims to introduce national regulations in Japan for diagnostics in the health surveillance, certification, therapy and compensation of vibration disease and evaluates them in the present perspective. Relevant laws, regulations and administrative directives were described in chronological order. Effect of those laws, regulations and directives were evaluated by statistics. Relevant regulations were established in 1947 and were revised in the 1960s and 1970s. According to those regulations, administrative directives were issued. Relevant vibration-disease statistics improved from the 1970s to 1990s. The annual ratio of workers examined was 95% to 100% in national forests (NFs), 47.3% in 1980 and 40.8% in 1990 in private industry (PI). The number of workers certified in NFs was 1,796 from 1971-1975, with a decrease to nine from 1991-1995, while in PI there were 9,783 from 1976-1980, decreasing to 2,331 from 1991-1995. However, in the construction industry the number increased again in the 1990s. The top four workers certified by the type of tool from 1994-1997 were operators of rock drills, chainsaws, pick hammers and concrete vibrators. The annual number of workers under treatment (at highest level) was 3,605 (1982; NFs) and 13,501 (1987; PI), with a decrease to 3,481 (1997; NFs) and 8,958 (1997; PI). Regulations for compensation covered 3,670 workers from 1965 to 1997 (NFs) and 22,723 from 1976 to 1997 (PI) in medical treatment benefits, and 189 (NFs) and 15,448 (PI) in disability benefits during the same term. The national regulations developed in Japan since 1965 for health surveillance, certification, therapy and compensation of hand-transmitted vibration disease have proven effective for prevention and compensation of vibration disease in many industries, but unsolved problems remain in the construction industry.

  19. 29 CFR 1915.132 - Portable electric tools.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Portable electric tools. 1915.132 Section 1915.132 Labor... § 1915.132 Portable electric tools. The provisions of this section shall apply to ship repairing... frames of portable electric tools and appliances, except double insulated tools approved by Underwriters...

  20. 29 CFR 1915.132 - Portable electric tools.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Portable electric tools. 1915.132 Section 1915.132 Labor... § 1915.132 Portable electric tools. The provisions of this section shall apply to ship repairing... frames of portable electric tools and appliances, except double insulated tools approved by Underwriters...

  1. 29 CFR 1915.132 - Portable electric tools.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Portable electric tools. 1915.132 Section 1915.132 Labor... § 1915.132 Portable electric tools. The provisions of this section shall apply to ship repairing... frames of portable electric tools and appliances, except double insulated tools approved by Underwriters...

  2. 29 CFR 1915.132 - Portable electric tools.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Portable electric tools. 1915.132 Section 1915.132 Labor... § 1915.132 Portable electric tools. The provisions of this section shall apply to ship repairing... frames of portable electric tools and appliances, except double insulated tools approved by Underwriters...

  3. 29 CFR 1915.132 - Portable electric tools.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Portable electric tools. 1915.132 Section 1915.132 Labor... § 1915.132 Portable electric tools. The provisions of this section shall apply to ship repairing... frames of portable electric tools and appliances, except double insulated tools approved by Underwriters...

  4. Identification of vibrational signatures from short chains of interlinked molecule-nanoparticle junctions obtained by inelastic electron tunnelling spectroscopy

    NASA Astrophysics Data System (ADS)

    Jafri, S. H. M.; Löfås, H.; Fransson, J.; Blom, T.; Grigoriev, A.; Wallner, A.; Ahuja, R.; Ottosson, H.; Leifer, K.

    2013-05-01

    Short chains containing a series of metal-molecule-nanoparticle nanojunctions are a nano-material system with the potential to give electrical signatures close to those from single molecule experiments while enabling us to build portable devices on a chip. Inelastic electron tunnelling spectroscopy (IETS) measurements provide one of the most characteristic electrical signals of single and few molecules. In interlinked molecule-nanoparticle (NP) chains containing typically 5-7 molecules in a chain, the spectrum is expected to be a superposition of the vibrational signatures of individual molecules. We have established a stable and reproducible molecule-AuNP multi-junction by placing a few 1,8-octanedithiol (ODT) molecules onto a versatile and portable nanoparticle-nanoelectrode platform and measured for the first time vibrational molecular signatures at complex and coupled few-molecule-NP junctions. From quantum transport calculations, we model the IETS spectra and identify vibrational modes as well as the number of molecules contributing to the electron transport in the measured spectra.Short chains containing a series of metal-molecule-nanoparticle nanojunctions are a nano-material system with the potential to give electrical signatures close to those from single molecule experiments while enabling us to build portable devices on a chip. Inelastic electron tunnelling spectroscopy (IETS) measurements provide one of the most characteristic electrical signals of single and few molecules. In interlinked molecule-nanoparticle (NP) chains containing typically 5-7 molecules in a chain, the spectrum is expected to be a superposition of the vibrational signatures of individual molecules. We have established a stable and reproducible molecule-AuNP multi-junction by placing a few 1,8-octanedithiol (ODT) molecules onto a versatile and portable nanoparticle-nanoelectrode platform and measured for the first time vibrational molecular signatures at complex and coupled few-molecule-NP junctions. From quantum transport calculations, we model the IETS spectra and identify vibrational modes as well as the number of molecules contributing to the electron transport in the measured spectra. Electronic supplementary information (ESI) available: Methods and materials. Details of the ab initio calculation of molecular vibrations and inelastic spectra of ODT between two Au electrodes. A model of carrier transport through the molecular junctions. See DOI: 10.1039/c3nr00505d

  5. Portable Life Support Stretcher Unit (PLSSU) Environmental Tests: Preproduction Model.

    DTIC Science & Technology

    1982-06-01

    fixture was taken out by fluttering of the castering wheels since the securing straps were too soft to transmit the motion. At higher frequencies, it was...5 3.3 Proof Tests . . . 6 3.4 Vibration Tests . . . 9 3.4.1 General . . . 9 3.4.2 Pretest Inspection . . . 12 3.4.3 Vertical Vibration on Wheels ...14 3.4.4 Horizontal Vibration on Wheels . . . 15 3.4.5 Horizontal Vibration with Handle Suspension . . . 16 3.4.6 Vertical Vibration with Handle

  6. Investigation of 1-Dimensional ultrasonic vibration compliance mechanism based on finite element analysis

    NASA Astrophysics Data System (ADS)

    Latif, A. Afiff; Ibrahim, M. Rasidi; Rahim, E. A.; Cheng, K.

    2017-04-01

    The conventional milling has many difficulties in the processing of hard and brittle material. Hence, ultrasonic vibration assisted milling (UVAM) was proposed to overcome this problem. The objective of this research is to study the behavior of compliance mechanism (CM) as the critical part affect the performance of the UVAM. The design of the CM was investigated and focuses on 1-Dimensional. Experimental result was obtained from a portable laser digital vibrometer. While the 1-Dimensional value such as safety factor, deformation of hinges and stress analysis are obtained from finite elements simulation. Finally, the findings help to find the best design judging from the most travelled distance of the piezoelectric actuators. In addition, this paper would provide a clear picture the behavior of the CM embedded in the UVAM, which can provide good data and to improve the machining on reducing tool wear, and lower cutting force on the workpiece surface roughness.

  7. Research of a smart cutting tool based on MEMS strain gauge

    NASA Astrophysics Data System (ADS)

    Zhao, Y.; Zhao, Y. L.; Shao, YW; Hu, T. J.; Zhang, Q.; Ge, X. H.

    2018-03-01

    Cutting force is an important factor that affects machining accuracy, cutting vibration and tool wear. Machining condition monitoring by cutting force measurement is a key technology for intelligent manufacture. Current cutting force sensors exist problems of large volume, complex structure and poor compatibility in practical application, for these problems, a smart cutting tool is proposed in this paper for cutting force measurement. Commercial MEMS (Micro-Electro-Mechanical System) strain gauges with high sensitivity and small size are adopted as transducing element of the smart tool, and a structure optimized cutting tool is fabricated for MEMS strain gauge bonding. Static calibration results show that the developed smart cutting tool is able to measure cutting forces in both X and Y directions, and the cross-interference error is within 3%. Its general accuracy is 3.35% and 3.27% in X and Y directions, and sensitivity is 0.1 mV/N, which is very suitable for measuring small cutting forces in high speed and precision machining. The smart cutting tool is portable and reliable for practical application in CNC machine tool.

  8. Identification of vibrational signatures from short chains of interlinked molecule-nanoparticle junctions obtained by inelastic electron tunnelling spectroscopy.

    PubMed

    Jafri, S H M; Löfås, H; Fransson, J; Blom, T; Grigoriev, A; Wallner, A; Ahuja, R; Ottosson, H; Leifer, K

    2013-06-07

    Short chains containing a series of metal-molecule-nanoparticle nanojunctions are a nano-material system with the potential to give electrical signatures close to those from single molecule experiments while enabling us to build portable devices on a chip. Inelastic electron tunnelling spectroscopy (IETS) measurements provide one of the most characteristic electrical signals of single and few molecules. In interlinked molecule-nanoparticle (NP) chains containing typically 5-7 molecules in a chain, the spectrum is expected to be a superposition of the vibrational signatures of individual molecules. We have established a stable and reproducible molecule-AuNP multi-junction by placing a few 1,8-octanedithiol (ODT) molecules onto a versatile and portable nanoparticle-nanoelectrode platform and measured for the first time vibrational molecular signatures at complex and coupled few-molecule-NP junctions. From quantum transport calculations, we model the IETS spectra and identify vibrational modes as well as the number of molecules contributing to the electron transport in the measured spectra.

  9. A vibrational spectroscopic and principal component analysis of triarylmethane dyes by comparative laboratory and portable instrumentation

    NASA Astrophysics Data System (ADS)

    Doherty, B.; Vagnini, M.; Dufourmantelle, K.; Sgamellotti, A.; Brunetti, B.; Miliani, C.

    2014-03-01

    This contribution examines the utility of vibrational spectroscopy by bench and portable Raman/surface enhanced Raman and infrared methods for the investigation of ten early triarlymethane dye powder references and dye solutions applied on paper. The complementary information afforded by the techniques is shown to play a key role in the identification of specific spectral marker ranges to distiguish early synthetic dyes of art-historical interest through the elaboration of an in-house database of modern organic dyes. Chemometric analysis has permitted a separation of data by the discrimination of di-phenyl-naphthalenes and triphenylmethanes (di-amino and tri-amino derivatives). This work serves as a prelude to the validation of a non-invasive working method for in situ characterization of these synthetic dyes through a careful comparison of respective strengths and limitations of each portable technique.

  10. Improved sensitivity of wearable nanogenerators made of electrospun Eu3+ doped P(VDF-HFP)/graphene composite nanofibers for self-powered voice recognition

    NASA Astrophysics Data System (ADS)

    Adhikary, Prakriti; Biswas, Anirban; Mandal, Dipankar

    2016-12-01

    Composite nanofibers of Eu3+ doped poly(vinylidene fluoride-co-hexafluoropropylene) (P(VDF-HFP))/graphene are prepared by the electrospinning technique for the fabrication of ultrasensitive wearable piezoelectric nanogenerators (WPNGs) where the post-poling technique is not necessary. It is found that the complete conversion of the piezoelectric β-phase and the improvement of the degree of crystallinity is governed by the incorporation of Eu3+ and graphene sheets into P(VDF-HFP) nanofibers. The flexible nanocomposite fibers are associated with a hypersensitive electronic transition that results in an intense red light emission, and WPNGs also have the capability of detecting external pressure as low as ~23 Pa with a higher degree of acoustic sensitivity, ~11 V Pa-1, than has ever been previously reported. This means that ultrasensitive WPNGs can be utilized to recognize human voices, which suggests they could be a potential tool in the biomedical and national security sectors. The capacitor’s ability to charge from abundant environmental vibrations, such as music, wind, body motion, etc, drives WPNGs as a power source for portable electronics. This fact may open up the prospect of using the Eu3+ doped P(VDF-HFP)/graphene composite electrospun nanofibers, with their multifunctional properties such as vibration sensitivity, wearability, red light emission capability and piezoelectric energy harvesting, for various promising applications in portable electronics, health care monitoring, noise detection and security monitoring.

  11. Improved sensitivity of wearable nanogenerators made of electrospun Eu3+ doped P(VDF-HFP)/graphene composite nanofibers for self-powered voice recognition.

    PubMed

    Adhikary, Prakriti; Biswas, Anirban; Mandal, Dipankar

    2016-12-09

    Composite nanofibers of Eu 3+ doped poly(vinylidene fluoride-co-hexafluoropropylene) (P(VDF-HFP))/graphene are prepared by the electrospinning technique for the fabrication of ultrasensitive wearable piezoelectric nanogenerators (WPNGs) where the post-poling technique is not necessary. It is found that the complete conversion of the piezoelectric β-phase and the improvement of the degree of crystallinity is governed by the incorporation of Eu 3+ and graphene sheets into P(VDF-HFP) nanofibers. The flexible nanocomposite fibers are associated with a hypersensitive electronic transition that results in an intense red light emission, and WPNGs also have the capability of detecting external pressure as low as ~23 Pa with a higher degree of acoustic sensitivity, ~11 V Pa -1 , than has ever been previously reported. This means that ultrasensitive WPNGs can be utilized to recognize human voices, which suggests they could be a potential tool in the biomedical and national security sectors. The capacitor's ability to charge from abundant environmental vibrations, such as music, wind, body motion, etc, drives WPNGs as a power source for portable electronics. This fact may open up the prospect of using the Eu 3+ doped P(VDF-HFP)/graphene composite electrospun nanofibers, with their multifunctional properties such as vibration sensitivity, wearability, red light emission capability and piezoelectric energy harvesting, for various promising applications in portable electronics, health care monitoring, noise detection and security monitoring.

  12. 29 CFR 1910.242 - Hand and portable powered tools and equipment, general.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. ... 29 Labor 5 2011-07-01 2011-07-01 false Hand and portable powered tools and equipment, general... Powered Tools and Other Hand-Held Equipment § 1910.242 Hand and portable powered tools and equipment...

  13. 29 CFR 1910.242 - Hand and portable powered tools and equipment, general.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. ... 29 Labor 5 2010-07-01 2010-07-01 false Hand and portable powered tools and equipment, general... Powered Tools and Other Hand-Held Equipment § 1910.242 Hand and portable powered tools and equipment...

  14. Metamaterial split ring resonator as a sensitive mechanical vibration sensor

    NASA Astrophysics Data System (ADS)

    Sikha Simon, K.; Chakyar, Sreedevi P.; Andrews, Jolly; Joseph V., P.

    2017-06-01

    This paper introduces a sensitive vibration sensor based on microwave metamaterial Split Ring Resonator (SRR) capable of detecting any ground vibration. The experimental setup consists of single Broad-side Coupled SRR (BCSRR) unit fixed on a cantilever capable of sensitive vibrations. It is arranged between transmitting and receiving probes of a microwave measurement system. The absorption level variations at the resonant frequency due to the displacement from the reference plane of SRR, which is a function of the strength of external mechanical vibration, is analyzed. This portable and cost effective sensor working on a single frequency is observed to be capable of detecting even very weak vibrations. This may find potential applications in the field of tamper-proofing, mining, quarrying and earthquake sensing.

  15. The development of interior noise and vibration criteria

    NASA Technical Reports Server (NTRS)

    Leatherwood, J. D.; Clevenson, S. A.; Stephens, D. G.

    1990-01-01

    A generalized model was developed for estimating passenger discomfort response to combined noise and vibration. This model accounts for broadband noise and vibration spectra and multiple axes of vibration as well as the interactive effects of combined noise and vibration. The model has the unique capability of transforming individual components of noise/vibration environment into subjective comfort units and then combining these comfort units to produce a total index of passenger discomfort and useful sub-indices that typify passenger comfort within the environment. An overview of the model development is presented including the methodology employed, major elements of the model, model applications, and a brief description of a commercially available portable ride comfort meter based directly upon the model algorithms. Also discussed are potential criteria formats that account for the interactive effects of noise and vibration on human discomfort response.

  16. Portable Roller Staking Tool

    NASA Technical Reports Server (NTRS)

    Bird, R. G.; Berson, L. A.

    1983-01-01

    Staking tool compact and portable. Tool combines clamping and staking operations in single unit. Tool clamps workpiece (a bearing or bushing), alines it, and stakes on of flat faces. Used for most roller staking operations which acess both faces of workpiece.

  17. A method for the measurement and analysis of ride vibrations of transportation systems

    NASA Technical Reports Server (NTRS)

    Catherines, J. J.; Clevenson, S. A.; Scholl, H. F.

    1972-01-01

    The measurement and recording of ride vibrations which affect passenger comfort in transportation systems and the subsequent data-reduction methods necessary for interpreting the data present exceptional instrumentation requirements and necessitate the use of computers for specialized analysis techniques. A method is presented for both measuring and analyzing ride vibrations of the type encountered in ground and air transportation systems. A portable system for measuring and recording low-frequency, low-amplitude accelerations and specialized data-reduction procedures are described. Sample vibration measurements in the form of statistical parameters representative of typical transportation systems are also presented to demonstrate the utility of the techniques.

  18. Review of magnetostrictive vibration energy harvesters

    NASA Astrophysics Data System (ADS)

    Deng, Zhangxian; Dapino, Marcelo J.

    2017-10-01

    The field of energy harvesting has grown concurrently with the rapid development of portable and wireless electronics in which reliable and long-lasting power sources are required. Electrochemical batteries have a limited lifespan and require periodic recharging. In contrast, vibration energy harvesters can supply uninterrupted power by scavenging useful electrical energy from ambient structural vibrations. This article reviews the current state of vibration energy harvesters based on magnetostrictive materials, especially Terfenol-D and Galfenol. Existing magnetostrictive harvester designs are compared in terms of various performance metrics. Advanced techniques that can reduce device size and improve performance are presented. Models for magnetostrictive devices are summarized to guide future harvester designs.

  19. Study on antilock brake system with elastic membrane vibration generated by controlled solenoid excitation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wibowo,, E-mail: wibowo-uns@yahoo.com; Zakaria,, E-mail: zakaaria27@gmail.com; Lambang, Lullus, E-mail: lulus-l@yahoo.com

    The most effective chassis control system for improving vehicle safety during severe braking is anti-lock braking system (ABS). Antilock effect can be gained by vibrate the pad brake at 7 to 20 cycle per second. The aim of this study is to design a new method of antilock braking system with membrane elastic vibrated by solenoid. The influence of the pressure fluctuations of brake fluid is investigated. Vibration data is collected using a small portable accelerometer-slam stick. The experiment results that the vibration of brake pad caused by controlled solenoid excitation at 10 Hz is obtained by our new method. Themore » result of measurements can be altered by varying brake fluid pressure.« less

  20. Study on antilock brake system with elastic membrane vibration generated by controlled solenoid excitation

    NASA Astrophysics Data System (ADS)

    Wibowo, Zakaria, Lambang, Lullus; Triyono, Muhayat, Nurul

    2016-03-01

    The most effective chassis control system for improving vehicle safety during severe braking is anti-lock braking system (ABS). Antilock effect can be gained by vibrate the pad brake at 7 to 20 cycle per second. The aim of this study is to design a new method of antilock braking system with membrane elastic vibrated by solenoid. The influence of the pressure fluctuations of brake fluid is investigated. Vibration data is collected using a small portable accelerometer-slam stick. The experiment results that the vibration of brake pad caused by controlled solenoid excitation at 10 Hz is obtained by our new method. The result of measurements can be altered by varying brake fluid pressure.

  1. Tool-specific performance of vibration-reducing gloves for attenuating fingers-transmitted vibration

    PubMed Central

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.

    2016-01-01

    BACKGROUND Fingers-transmitted vibration can cause vibration-induced white finger. The effectiveness of vibration-reducing (VR) gloves for reducing hand transmitted vibration to the fingers has not been sufficiently examined. OBJECTIVE The objective of this study is to examine tool-specific performance of VR gloves for reducing finger-transmitted vibrations in three orthogonal directions (3D) from powered hand tools. METHODS A transfer function method was used to estimate the tool-specific effectiveness of four typical VR gloves. The transfer functions of the VR glove fingers in three directions were either measured in this study or during a previous study using a 3D laser vibrometer. More than seventy vibration spectra of various tools or machines were used in the estimations. RESULTS When assessed based on frequency-weighted acceleration, the gloves provided little vibration reduction. In some cases, the gloves amplified the vibration by more than 10%, especially the neoprene glove. However, the neoprene glove did the best when the assessment was based on unweighted acceleration. The neoprene glove was able to reduce the vibration by 10% or more of the unweighted vibration for 27 out of the 79 tools. If the dominant vibration of a tool handle or workpiece was in the shear direction relative to the fingers, as observed in the operation of needle scalers, hammer chisels, and bucking bars, the gloves did not reduce the vibration but increased it. CONCLUSIONS This study confirmed that the effectiveness for reducing vibration varied with the gloves and the vibration reduction of each glove depended on tool, vibration direction to the fingers, and finger location. VR gloves, including certified anti-vibration gloves do not provide much vibration reduction when judged based on frequency-weighted acceleration. However, some of the VR gloves can provide more than 10% reduction of the unweighted vibration for some tools or workpieces. Tools and gloves can be matched for better effectiveness for protecting the fingers. PMID:27867313

  2. Portable vibration-assisted filtration device for on-site isolation of blood cells or pathogenic bacteria from whole human blood.

    PubMed

    Kim, Yong Tae; Park, Kyun Joo; Kim, Seyl; Kim, Soon Ae; Lee, Seok Jae; Kim, Do Hyun; Lee, Tae Jae; Lee, Kyoung G

    2018-03-01

    Isolation of specific cells from whole blood is important to monitor disease prognosis and diagnosis. In this study, a vibration-assisted filtration (VF) device has been developed for isolation and recovery of specific cells such as leukocytes and pathogenic bacteria from human whole blood. The VF device is composed of three layers which was fabricated using injection molding with cyclic olefin copolymer (COC) pellets consisting of: a top layer with coin-type vibration motor (Ф = 10mm), a middle plate with a 1μm or 3μm-pore filter membrane to separate of Staphylococcus aureus (S. aureus) cells or leukocytes (i.e. white blood cells) respectively, and a bottom chamber with conical-shaped microstructure. One milliliter of human whole blood was injected into a sample loading chamber using a 3μm-pore filter equipped in the VF device and the coin-type vibration motor applied external vibration force by generating a rotational fluid which enhances the filtration velocity due to the prevention of the cell clogging on the filter membrane. The effluent blood such as erythrocytes, platelet, and plasma was collected at the bottom chamber while the leukocytes were sieved by the filter membrane. The vibration-assisted leukocyte separation was able to finish within 200s while leukocyte separation took 1200s without vibration. Moreover, we successfully separated S. aureus from human whole blood using a 1μm-pore filter equipped VF device and it was further confirmed by genetic analysis. The proposed VF device provides an advanced cell separation platform in terms of simplicity, fast separation, and portability in the fields of point-of-care diagnostics. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Evaluating the effectiveness of gloves in reducing the hazards of hand-transmitted vibration.

    PubMed

    Griffin, M J

    1998-05-01

    A method of evaluating the effectiveness of gloves in reducing the hazards of hand-transmitted vibration is proposed. The glove isolation effectiveness was calculated from: (a) the measured transmissibility of a glove, (b) the vibration spectrum on the handle of a specific tool (or class of tools), and (c) the frequency weighting indicating the degree to which different frequencies of vibration cause injury. With previously reported tool vibration spectra and glove transmissibilities (from 10-1000 Hz), the method was used to test 10 gloves with 20 different powered tools. The frequency weighting for hand-transmitted vibration advocated in British standard 6842 (1987) and international standard 5349 (1986) greatly influences the apparent isolation effectiveness of gloves. With the frequency weighting, the gloves had little effect on the transmission of vibration to the hand from most of the tools. Only for two or three tools (those dominated by high frequency vibration) did any glove provide useful attenuation. Without the frequency weighting, some gloves showed useful attenuation of the vibration on most powered tools. In view of the uncertain effect of the vibration frequency in the causation of disorders from hand-transmitted vibration, it is provisionally suggested that the wearing of a glove by the user of a particular vibratory tool could be encouraged if the glove reduces the transmission of vibration when it is evaluated without the frequency weighting and does not increase the vibration when it is evaluated with the frequency weighting. A current international standard for the measurement and evaluation of the vibration transmitted by gloves can classify a glove as an antivibration glove when it provides no useful attenuation of vibration, whereas a glove providing useful attenuation of vibration on a specific tool can fail the test.

  4. Footbridge system identification using wireless inertial measurement units for force and response measurements

    NASA Astrophysics Data System (ADS)

    Brownjohn, James Mark William; Bocian, Mateusz; Hester, David; Quattrone, Antonino; Hudson, William; Moore, Daniel; Goh, Sushma; Lim, Meng Sun

    2016-12-01

    With the main focus on safety, design of structures for vibration serviceability is often overlooked or mismanaged, resulting in some high profile structures failing publicly to perform adequately under human dynamic loading due to walking, running or jumping. A standard tool to inform better design, prove fitness for purpose before entering service and design retrofits is modal testing, a procedure that typically involves acceleration measurements using an array of wired sensors and force generation using a mechanical shaker. A critical but often overlooked aspect is using input (force) to output (response) relationships to enable estimation of modal mass, which is a key parameter directly controlling vibration levels in service. This paper describes the use of wireless inertial measurement units (IMUs), designed for biomechanics motion capture applications, for the modal testing of a 109 m footbridge. IMUs were first used for an output-only vibration survey to identify mode frequencies, shapes and damping ratios, then for simultaneous measurement of body accelerations of a human subject jumping to excite specific vibrations modes and build up bridge deck accelerations at the jumping location. Using the mode shapes and the vertical acceleration data from a suitable body landmark scaled by body mass, thus providing jumping force data, it was possible to create frequency response functions and estimate modal masses. The modal mass estimates for this bridge were checked against estimates obtained using an instrumented hammer and known mass distributions, showing consistency among the experimental estimates. Finally, the method was used in an applied research application on a short span footbridge where the benefits of logistical and operational simplicity afforded by the highly portable and easy to use IMUs proved extremely useful for an efficient evaluation of vibration serviceability, including estimation of modal masses.

  5. Vibration in car repair work.

    PubMed

    Hansson, J E; Eklund, L; Kihlberg, S; Ostergren, C E

    1987-03-01

    The main objective of the study was to find efficient hand tools which caused only minor vibration loading. Vibration measurements were carried out under standardised working conditions. The time during which car body repairers in seven companies were exposed to vibration was determined. Chisel hammers, impact wrenches, sanders and saws were the types of tools which generated the highest vibration accelerations. The average daily exposure at the different garages ranged from 22 to 70 min. The risk of vibration injury is currently rated as high. The difference between the highest and lowest levels of vibration was considerable in most tool categories. Therefore the choice of tool has a major impact on the magnitude of vibration exposure. The importance of choosing the right tools and working methods is discussed and a counselling service on vibration is proposed.

  6. Vibration mode analysis of the proton exchange membrane fuel cell stack

    NASA Astrophysics Data System (ADS)

    Liu, B.; Liu, L. F.; Wei, M. Y.; Wu, C. W.

    2016-11-01

    Proton exchange membrane fuel cell (PEMFC) stacks usually undergo vibration during packing, transportation, and serving time, in particular for those used in the automobiles or portable equipment. To study the stack vibration response, based on finite element method (FEM), a mode analysis is carried out in the present paper. Using this method, we can distinguish the local vibration from the stack global modes, predict the vibration responses, such as deformed shape and direction, and discuss the effects of the clamping configuration and the clamping force magnitude on vibration modes. It is found that when the total clamping force remains the same, increasing the bolt number can strengthen the stack resistance to vibration in the clamping direction, but cannot obviously strengthen stack resistance to vibration in the translations perpendicular to clamping direction and the three axis rotations. Increasing the total clamping force can increase both of the stack global mode and the bolt local mode frequencies, but will decrease the gasket local mode frequency.

  7. Tool-specific performance of vibration-reducing gloves for attenuating palm-transmitted vibrations in three orthogonal directions

    PubMed Central

    Dong, Ren G.; Welcome, Daniel E.; Peterson, Donald R.; Xu, Xueyan S.; McDowell, Thomas W.; Warren, Christopher; Asaki, Takafumi; Kudernatsch, Simon; Brammer, Antony

    2015-01-01

    Vibration-reducing (VR) gloves have been increasingly used to help reduce vibration exposure, but it remains unclear how effective these gloves are. The purpose of this study was to estimate tool-specific performances of VR gloves for reducing the vibrations transmitted to the palm of the hand in three orthogonal directions (3-D) in an attempt to assess glove effectiveness and aid in the appropriate selection of these gloves. Four typical VR gloves were considered in this study, two of which can be classified as anti-vibration (AV) gloves according to the current AV glove test standard. The average transmissibility spectrum of each glove in each direction was synthesized based on spectra measured in this study and other spectra collected from reported studies. More than seventy vibration spectra of various tools or machines were considered in the estimations, which were also measured in this study or collected from reported studies. The glove performance assessments were based on the percent reduction of frequency-weighted acceleration as is required in the current standard for assessing the risk of vibration exposures. The estimated tool-specific vibration reductions of the gloves indicate that the VR gloves could slightly reduce (<5%) or marginally amplify (<10%) the vibrations generated from low-frequency (<25 Hz) tools or those vibrating primarily along the axis of the tool handle. With other tools, the VR gloves could reduce palm-transmitted vibrations in the range of 5%–58%, primarily depending on the specific tool and its vibration spectra in the three directions. The two AV gloves were not more effective than the other gloves with some of the tools considered in this study. The implications of the results are discussed. Relevance to industry Hand-transmitted vibration exposure may cause hand-arm vibration syndrome. Vibration-reducing gloves are considered as an alternative approach to reduce the vibration exposure. This study provides useful information on the effectiveness of the gloves when used with many tools for reducing the vibration transmitted to the palm in three directions. The results can aid in the appropriate selection and use of these gloves. PMID:26726275

  8. Authentication of Whey Protein Powders by Portable Mid-Infrared Spectrometers Combined with Pattern Recognition Analysis.

    PubMed

    Wang, Ting; Tan, Siow Ying; Mutilangi, William; Aykas, Didem P; Rodriguez-Saona, Luis E

    2015-10-01

    The objective of this study was to develop a simple and rapid method to differentiate whey protein types (WPC, WPI, and WPH) used for beverage manufacturing by combining the spectral signature collected from portable mid-infrared spectrometers and pattern recognition analysis. Whey protein powders from different suppliers are produced using a large number of processing and compositional variables, resulting in variation in composition, concentration, protein structure, and thus functionality. Whey protein powders including whey protein isolates, whey protein concentrates and whey protein hydrolysates were obtained from different suppliers and their spectra collected using portable mid-infrared spectrometers (single and triple reflection) by pressing the powder onto an Attenuated Total Reflectance (ATR) diamond crystal with a pressure clamp. Spectra were analyzed by soft independent modeling of class analogy (SIMCA) generating a classification model showing the ability to differentiate whey protein types by forming tight clusters with interclass distance values of >3, considered to be significantly different from each other. The major bands centered at 1640 and 1580 cm(-1) were responsible for separation and were associated with differences in amide I and amide II vibrations of proteins, respectively. Another important band in whey protein clustering was associated with carboxylate vibrations of acidic amino acids (∼1570 cm(-1)). The use of a portable mid-IR spectrometer combined with pattern recognition analysis showed potential for discriminating whey protein ingredients that can help to streamline the analytical procedure so that it is more applicable for field-based screening of ingredients. A rapid, simple and accurate method was developed to authenticate commercial whey protein products by using portable mid-infrared spectrometers combined with chemometrics, which could help ensure the functionality of whey protein ingredients in food applications. © 2015 Institute of Food Technologists®

  9. 29 CFR 1915.131 - General precautions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... electric cords for this purpose is prohibited. (b) When air tools of the reciprocating type are not in use, the dies and tools shall be removed. (c) All portable, power-driven circular saws shall be equipped... whip. (f) The moving parts of drive mechanisms, such as gearing and belting on large portable tools...

  10. 29 CFR 1915.131 - General precautions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... electric cords for this purpose is prohibited. (b) When air tools of the reciprocating type are not in use, the dies and tools shall be removed. (c) All portable, power-driven circular saws shall be equipped... whip. (f) The moving parts of drive mechanisms, such as gearing and belting on large portable tools...

  11. 29 CFR 1915.131 - General precautions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... electric cords for this purpose is prohibited. (b) When air tools of the reciprocating type are not in use, the dies and tools shall be removed. (c) All portable, power-driven circular saws shall be equipped... whip. (f) The moving parts of drive mechanisms, such as gearing and belting on large portable tools...

  12. Vibration syndrome in chipping and grinding workers.

    PubMed

    1984-10-01

    A clear conclusion from these studies is that vibration syndrome occurs in chipping and grinding workers in this country and that earlier reports that it may not exist were probably inaccurate. The careful selection of exposed and control groups for analysis strengthens the observed association between vibration syndrome and the occupational use of pneumatic chipping hammers and grinding tools. In the foundry populations studied the vibration syndrome was severe, with short latencies and high prevalences of the advanced stages. The shipyard population did not display this pattern. This difference can be attributed to variations in work practices but the more important factor seems to be the effect of incentive work schedules. Comparisons of groups of hourly and incentive workers from the shipyard and within foundry populations consistently demonstrated that incentive work was associated with increased severity of vibration syndrome. Excessive vibration levels were measured on chipping and grinding tools. Of the factors studied, reduction of throttle level decreased the vibration levels measured on chipping hammers. For grinders, the working condition of the tool affected the measured vibration acceleration levels. Grinders receiving average to poor maintenance showed higher vibration levels. The results of objective clinical testing did not yield tests with diagnostic properties. To date, the clinical judgment of the physician remains the primary focus of the diagnosis of vibration syndrome. A number of actions can be taken to prevent vibration syndrome. Preplacement medical examinations can identify workers predisposed to or experiencing Raynaud's phenomenon or disease. Informing employees and employers about the signs, symptoms, and consequences of vibration syndrome can encourage workers to report the condition to their physicians promptly. Engineering approaches to preventing vibration syndrome include increased quality control on castings to reduce finishing time and automation of the finishing process. Tool manufacturers can contribute by modifying or redesigning tools to reduce vibration. The technology to reduce vibration from hand tools exists but the engineering application is difficult. Vibration from chain saws has been reduced through changes in design and some companies have begun to redesign jackhammers, scalers, grinders, and chipping hammers. As these become available, purchasers can encourage manufacturers by selecting tools with antivibration characteristics. Vibration from tools currently in use can be controlled by periodically scheduled inspection and maintenance programs for vibrating tools.(ABSTRACT TRUNCATED AT 400 WORDS)

  13. 17. NBS TOOL ROOM. MISCELLANEOUS TOOLS USED DURING EXTRA VEHICULAR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. NBS TOOL ROOM. MISCELLANEOUS TOOLS USED DURING EXTRA VEHICULAR ACTIVITY (EVA) MISSIONS AND NBS TRAINING. FROM LEFT TO RIGHT THE TOOLS ARE: SHUTTLE TRANSPORTATION SYSTEM (STS) PORTABLE FOOT RESTRAINT (PFR), ESSEX WRENCH, SOCKET WRENCH, SAFETY TETHER REEL (LEFT REAR), MINI WORKSTATION (CENTER REAR), TETHERS (FRONT CENTER), HUBBLE SPACE TELESCOPE (HST) POWER TOOL (FRONT RIGHT), HUBBLE SPACE TELESCOPE & PORTABLE FOOT RESTRAINT (REAR RIGHT). - Marshall Space Flight Center, Neutral Buoyancy Simulator Facility, Rideout Road, Huntsville, Madison County, AL

  14. Detection of fatty product falsifications using a portable near infrared spectrometer

    NASA Astrophysics Data System (ADS)

    Kalinin, A. V.; Krasheninnikov, V. N.

    2017-01-01

    Spreading sales of counterfeited fatty-oil foods leads to a development of portable and operational analyzer of typical fatty acids (FA) which may be a near infrared (NIR) spectrometer. In this work the calibration models for prediction of named FA were built with the spectra of FT-NIR spectrometer for different absorption bands of the FA. The best parameters were obtained for the wavelength sub-band 1.0-1.8 μ, which includes the 2nd and 3rd overtones of C-H stretching vibrations (near 1.7 and 1.2 μ) and the combination band (1.42 μ). Applicability of the portable spectrometer based on linear NIR array photosensor for the quality analysis of spread, butter and fish oil by the typical FA has been tested.

  15. SABrE User's Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, S.A.

    In computing landscape which has a plethora of different hardware architectures and supporting software systems ranging from compilers to operating systems, there is an obvious and strong need for a philosophy of software development that lends itself to the design and construction of portable code systems. The current efforts to standardize software bear witness to this need. SABrE is an effort to implement a software development environment which is itself portable and promotes the design and construction of portable applications. SABrE does not include such important tools as editors and compilers. Well built tools of that kind are readily availablemore » across virtually all computer platforms. The areas that SABrE addresses are at a higher level involving issues such as data portability, portable inter-process communication, and graphics. These blocks of functionality have particular significance to the kind of code development done at LLNL. That is partly why the general computing community has not supplied us with these tools already. This is another key feature of the software development environments which we must recognize. The general computing community cannot and should not be expected to produce all of the tools which we require.« less

  16. SABrE User`s Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, S.A.

    In computing landscape which has a plethora of different hardware architectures and supporting software systems ranging from compilers to operating systems, there is an obvious and strong need for a philosophy of software development that lends itself to the design and construction of portable code systems. The current efforts to standardize software bear witness to this need. SABrE is an effort to implement a software development environment which is itself portable and promotes the design and construction of portable applications. SABrE does not include such important tools as editors and compilers. Well built tools of that kind are readily availablemore » across virtually all computer platforms. The areas that SABrE addresses are at a higher level involving issues such as data portability, portable inter-process communication, and graphics. These blocks of functionality have particular significance to the kind of code development done at LLNL. That is partly why the general computing community has not supplied us with these tools already. This is another key feature of the software development environments which we must recognize. The general computing community cannot and should not be expected to produce all of the tools which we require.« less

  17. Low-frequency wideband vibration energy harvesting by using frequency up-conversion and quin-stable nonlinearity

    NASA Astrophysics Data System (ADS)

    Wang, Chen; Zhang, Qichang; Wang, Wei

    2017-07-01

    This work presents models and experiments of an impact-driven and frequency up-converted wideband piezoelectric-based vibration energy harvester with a quintuple-well potential induced by the combination effect of magnetic nonlinearity and mechanical piecewise-linearity. Analysis shows that the interwell motions during coupled vibration period enable to increase electrical power output in comparison to conventional frequency up-conversion technology. Besides, the quintuple-well potential with shallower potential wells could extend the harvester's operating bandwidth to lower frequencies. Experiments demonstrate our proposed approach can dramatically boost the measured power of the energy harvester as much as 35 times while its lower cut-off frequency is two times lower than that of a conventional counterpart. These results reveal our proposed approach shows promise for powering portable wireless smart devices from low-intensity, low-frequency vibration sources.

  18. Safety with Hand and Portable Power Tools. Module SH-14. Safety and Health.

    ERIC Educational Resources Information Center

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on safety with hand and portable power tools is one of 50 modules concerned with job safety and health. This module discusses the proper use and maintenance of tools, including the need for protective equipment for the worker. Following the introduction, 16 objectives (each keyed to a page in the text) the student is expected…

  19. Vibration reduction of pneumatic percussive rivet tools: mechanical and ergonomic re-design approaches.

    PubMed

    Cherng, John G; Eksioglu, Mahmut; Kizilaslan, Kemal

    2009-03-01

    This paper presents a systematic design approach, which is the result of years of research effort, to ergonomic re-design of rivet tools, i.e. rivet hammers and bucking bars. The investigation was carried out using both ergonomic approach and mechanical analysis of the rivet tools dynamic behavior. The optimal mechanical design parameters of the re-designed rivet tools were determined by Taguchi method. Two ergonomically re-designed rivet tools with vibration damping/isolation mechanisms were tested against two conventional rivet tools in both laboratory and field tests. Vibration characteristics of both types of tools were measured by laboratory tests using a custom-made test fixture. The subjective field evaluations of the tools were performed by six experienced riveters at an aircraft repair shop. Results indicate that the isolation spring and polymer damper are very effective in reducing the overall level of vibration under both unweighted and weighted acceleration conditions. The mass of the dolly head and the housing played a significant role in the vibration absorption of the bucking bars. Another important result was that the duct iron has better vibration reducing capability compared to steel and aluminum for bucking bars. Mathematical simulation results were also consistent with the experimental results. Overall conclusion obtained from the study was that by applying the design principles of ergonomics and by adding vibration damping/isolation mechanisms to the rivet tools, the vibration level can significantly be reduced and the tools become safer and user friendly. The details of the experience learned, design modifications, test methods, mathematical models and the results are included in the paper.

  20. Ergonomic analysis of fastening vibration based on ISO Standard 5349 (2001).

    PubMed

    Joshi, Akul; Leu, Ming; Murray, Susan

    2012-11-01

    Hand-held power tools used for fastening operations exert high dynamic forces on the operator's hand-arm, potentially causing injuries to the operator in the long run. This paper presents a study that analyzed the vibrations exerted by two hand-held power tools used for fastening operations with the operating exhibiting different postures. The two pneumatic tools, a right-angled nut-runner and an offset pistol-grip, are used to install shearing-type fasteners. A tri-axial accelerometer is used to measure the tool's vibration. The position and orientation of the transducer mounted on the tool follows the ISO-5349 Standard. The measured vibration data is used to compare the two power tools at different operating postures. The data analysis determines the number of years required to reach a 10% probability of developing finger blanching. The results indicate that the pistol-grip tool induces more vibration in the hand-arm than the right-angled nut-runner and that the vibrations exerted on the hand-arm vary for different postures. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  1. A simple low cost latent fingerprint sensor based on deflectometry and WFT analysis

    NASA Astrophysics Data System (ADS)

    Dhanotia, Jitendra; Chatterjee, Amit; Bhatia, Vimal; Prakash, Shashi

    2018-02-01

    In criminal investigations, latent fingerprints are one of the most significant forms of evidence and most commonly used forensic investigation tool worldwide. The existing non-contact latent fingerprint detection systems are bulky, expensive and require environment which is shock and vibration resistant, thereby limiting their usability outside the laboratory. In this article, a compact, full field, low cost technique for profiling of fingerprints using deflectometry is proposed. Using inexpensive mobile phone screen based structured illumination, and windowed Fourier transform (WFT) based phase retrieval mechanism, the 2D and 3D phase plots reconstruct the profile information of the fingerprint. The phase information is also used to confirm a match between two fingerprints in real time. Since the proposed technique is non-interferometric, the measurements are least affected by environmental perturbations. Using the proposed technique, a portable sensor capable of field deployment has been realized.

  2. A decade of innovation with laser speckle metrology

    NASA Astrophysics Data System (ADS)

    Ettemeyer, Andreas

    2003-05-01

    Speckle Pattern Interferometry has emerged from the experimental substitution of holographic interferometry to become a powerful problem solving tool in research and industry. The rapid development of computer and digital imaging techniques in combination with minaturization of the optical equipment led to new applications which had not been anticipated before. While classical holographic interferometry had always required careful consideration of the environmental conditions such as vibration, noise, light, etc. and could generally only be performed in the optical laboratory, it is now state of the art, to handle portable speckle measuring equipment at almost any place. During the last decade, the change in design and technique has dramatically influenced the range of applications of speckle metrology and opened new markets. The integration of recent research results into speckle measuring equipment has led to handy equipment, simplified the operation and created high quality data output.

  3. Bi-axial Vibration Energy Harvesting

    DTIC Science & Technology

    2012-07-01

    included early dedicated portable signal averaging equipment, Nomad, CT4 and F18 fatigue test control systems and some field trials. Currently he is...and repairs to acoustically- fatigued structures. ____________________ ________________________________________________ UNCLASSIFIED...Physicists at the Tokyo Institute of Technology investigated various piezoceramic materials [20], developing lead zirconate titanate ( PZT ) in around 1952

  4. The Use of Cloud Technology in Athletic Training Education

    ERIC Educational Resources Information Center

    Perkey, Dennis

    2012-01-01

    As technology advances and becomes more portable, athletic training educators (ATEs) have many options available to them. Whether attempting to streamline efforts in courses, or operate a more efficient athletic training education program, portable technology is becoming an important tool that will assist the ATE. One tool that allows more…

  5. Vibration detection of component health and operability

    NASA Technical Reports Server (NTRS)

    Baird, B. C.

    1975-01-01

    In order to prevent catastrophic failure and eliminate unnecessary periodic maintenance in the shuttle orbiter program environmental control system components, some means of detecting incipient failure in these components is required. The utilization was investigated of vibrational/acoustic phenomena as one of the principal physical parameters on which to base the design of this instrumentation. Baseline vibration/acoustic data was collected from three aircraft type fans and two aircraft type pumps over a frequency range from a few hertz to greater than 3000 kHz. The baseline data included spectrum analysis of the baseband vibration signal, spectrum analysis of the detected high frequency bandpass acoustic signal, and amplitude distribution of the high frequency bandpass acoustic signal. A total of eight bearing defects and two unbalancings was introduced into the five test items. All defects were detected by at least one of a set of vibration/acoustic parameters with a margin of at least 2:1 over the worst case baseline. The design of a portable instrument using this set of vibration/acoustic parameters for detecting incipient failures in environmental control system components is described.

  6. Experimental Study of Turning Temperature and Turning Vibration for the Tool of Different Wear State

    NASA Astrophysics Data System (ADS)

    Li, Shuncai; Yu, Qiu; Yuan, Guanlei; Liang, Li

    2018-03-01

    By a vibration test device and Vib’SYS analysis system, a three-dimensional piezoelectric acceleration sensor and an infrared thermometer and its collection system, the turning experiments under different spindle speeds were carried out on three cutting tools with different wear states, and the change law of cutting temperature at the tool tip and change law of three-dimensional vibration with turning time were obtained. The results indicate that: (1) The temperature of the initial wear tool and the middle wear tool under a small turning parameter increased slowly with turning time; while under a greater turning parameter, the temperature of the middle wear tool varies significantly with time; (2) The temperature of the severe wear tool increased sharply at the later feeding stage; (3) The change laws of the tools vibration acceleration maximum with the spindle speeds are similar for the initial wear tool and the middle wear tool, which shows a trend of increasing at first and then decreasing; (4) the average value of vibration acceleration self-power spectrum of severe wear tool constantly increase with the spindle speed; (5) the maximum impact is along the radial direction for the tools of different wear state.

  7. Laboratory and field measurements and evaluations of vibration at the handles of riveting hammers

    PubMed Central

    McDOWELL, THOMAS W.; WARREN, CHRISTOPHER; WELCOME, DANIEL E.; DONG, REN G.

    2015-01-01

    The use of riveting hammers can expose workers to harmful levels of hand-transmitted vibration (HTV). As a part of efforts to reduce HTV exposures through tool selection, the primary objective of this study was to evaluate the applicability of a standardized laboratory-based riveting hammer assessment protocol for screening riveting hammers. The second objective was to characterize the vibration emissions of reduced vibration riveting hammers and to make approximations of the HTV exposures of workers operating these tools in actual work tasks. Eight pneumatic riveting hammers were selected for the study. They were first assessed in a laboratory using the standardized method for measuring vibration emissions at the tool handle. The tools were then further assessed under actual working conditions during three aircraft sheet metal riveting tasks. Although the average vibration magnitudes of the riveting hammers measured in the laboratory test were considerably different from those measured in the field study, the rank orders of the tools determined via these tests were fairly consistent, especially for the lower vibration tools. This study identified four tools that consistently exhibited lower frequency-weighted and unweighted accelerations in both the laboratory and workplace evaluations. These observations suggest that the standardized riveting hammer test is acceptable for identifying tools that could be expected to exhibit lower vibrations in workplace environments. However, the large differences between the accelerations measured in the laboratory and field suggest that the standardized laboratory-based tool assessment is not suitable for estimating workplace riveting hammer HTV exposures. Based on the frequency-weighted accelerations measured at the tool handles during the three work tasks, the sheet metal mechanics assigned to these tasks at the studied workplace are unlikely to exceed the daily vibration exposure action value (2.5 m s−2) using any of the evaluated riveting hammers. PMID:22539561

  8. Nano Mechanical Machining Using AFM Probe

    NASA Astrophysics Data System (ADS)

    Mostofa, Md. Golam

    Complex miniaturized components with high form accuracy will play key roles in the future development of many products, as they provide portability, disposability, lower material consumption in production, low power consumption during operation, lower sample requirements for testing, and higher heat transfer due to their very high surface-to-volume ratio. Given the high market demand for such micro and nano featured components, different manufacturing methods have been developed for their fabrication. Some of the common technologies in micro/nano fabrication are photolithography, electron beam lithography, X-ray lithography and other semiconductor processing techniques. Although these methods are capable of fabricating micro/nano structures with a resolution of less than a few nanometers, some of the shortcomings associated with these methods, such as high production costs for customized products, limited material choices, necessitate the development of other fabricating techniques. Micro/nano mechanical machining, such an atomic force microscope (AFM) probe based nano fabrication, has, therefore, been used to overcome some the major restrictions of the traditional processes. This technique removes material from the workpiece by engaging micro/nano size cutting tool (i.e. AFM probe) and is applicable on a wider range of materials compared to the photolithographic process. In spite of the unique benefits of nano mechanical machining, there are also some challenges with this technique, since the scale is reduced, such as size effects, burr formations, chip adhesions, fragility of tools and tool wear. Moreover, AFM based machining does not have any rotational movement, which makes fabrication of 3D features more difficult. Thus, vibration-assisted machining is introduced into AFM probe based nano mechanical machining to overcome the limitations associated with the conventional AFM probe based scratching method. Vibration-assisted machining reduced the cutting forces and burr formations through intermittent cutting. Combining the AFM probe based machining with vibration-assisted machining enhanced nano mechanical machining processes by improving the accuracy, productivity and surface finishes. In this study, several scratching tests are performed with a single crystal diamond AFM probe to investigate the cutting characteristics and model the ploughing cutting forces. Calibration of the probe for lateral force measurements, which is essential, is also extended through the force balance method. Furthermore, vibration-assisted machining system is developed and applied to fabricate different materials to overcome some of the limitations of the AFM probe based single point nano mechanical machining. The novelty of this study includes the application of vibration-assisted AFM probe based nano scale machining to fabricate micro/nano scale features, calibration of an AFM by considering different factors, and the investigation of the nano scale material removal process from a different perspective.

  9. Energy evaluation of protection effectiveness of anti-vibration gloves.

    PubMed

    Hermann, Tomasz; Dobry, Marian Witalis

    2017-09-01

    This article describes an energy method of assessing protection effectiveness of anti-vibration gloves on the human dynamic structure. The study uses dynamic models of the human and the glove specified in Standard No. ISO 10068:2012. The physical models of human-tool systems were developed by combining human physical models with a power tool model. The combined human-tool models were then transformed into mathematical models from which energy models were finally derived. Comparative energy analysis was conducted in the domain of rms powers. The energy models of the human-tool systems were solved using numerical simulation implemented in the MATLAB/Simulink environment. The simulation procedure demonstrated the effectiveness of the anti-vibration glove as a method of protecting human operators of hand-held power tools against vibration. The desirable effect is achieved by lowering the flow of energy in the human-tool system when the anti-vibration glove is employed.

  10. Exposure assessment in health assessments for hand-arm vibration syndrome.

    PubMed

    Mason, H J; Poole, K; Young, C

    2011-08-01

    Assessing past cumulative vibration exposure is part of assessing the risk of hand-arm vibration syndrome (HAVS) in workers exposed to hand-arm vibration and invariably forms part of a medical assessment of such workers. To investigate the strength of relationships between the presence and severity of HAVS and different cumulative exposure metrics obtained from a self-reporting questionnaire. Cumulative exposure metrics were constructed from a tool-based questionnaire applied in a group of HAVS referrals and workplace field studies. These metrics included simple years of vibration exposure, cumulative total hours of all tool use and differing combinations of acceleration magnitudes for specific tools and their daily use, including the current frequency-weighting method contained in ISO 5349-1:2001. Use of simple years of exposure is a weak predictor of HAVS or its increasing severity. The calculation of cumulative hours across all vibrating tools used is a more powerful predictor. More complex calculations based on involving likely acceleration data for specific classes of tools, either frequency weighted or not, did not offer a clear further advantage in this dataset. This may be due to the uncertainty associated with workers' recall of their past tool usage or the variability between tools in the magnitude of their vibration emission. Assessing years of exposure or 'latency' in a worker should be replaced by cumulative hours of tool use. This can be readily obtained using a tool-pictogram-based self-reporting questionnaire and a simple spreadsheet calculation.

  11. Portable Wind Energy Harvesters for Low-Power Applications: A Survey

    PubMed Central

    Nabavi, Seyedfakhreddin; Zhang, Lihong

    2016-01-01

    Energy harvesting has become an increasingly important topic thanks to the advantages in renewability and environmental friendliness. In this paper, a comprehensive study on contemporary portable wind energy harvesters has been conducted. The electrical power generation methods of portable wind energy harvesters are surveyed in three major groups, piezoelectric-, electromagnetic-, and electrostatic-based generators. The paper also takes another view of this area by gauging the required mechanisms for trapping wind flow from ambient environment. In this regard, rotational and aeroelastic mechanisms are analyzed for the portable wind energy harvesting devices. The comparison between both mechanisms shows that the aeroelastic mechanism has promising potential in producing an energy harvester in smaller scale although how to maintain the resonator perpendicular to wind flow for collecting the maximum vibration is still a major challenge to overcome for this mechanism. Furthermore, this paper categorizes the previously published portable wind energy harvesters to macro and micro scales in terms of their physical dimensions. The power management systems are also surveyed to explore the possibility of improving energy conversion efficiency. Finally some insights and research trends are pointed out based on an overall analysis of the previously published works along the historical timeline. PMID:27438834

  12. Portable Wind Energy Harvesters for Low-Power Applications: A Survey.

    PubMed

    Nabavi, Seyedfakhreddin; Zhang, Lihong

    2016-07-16

    Energy harvesting has become an increasingly important topic thanks to the advantages in renewability and environmental friendliness. In this paper, a comprehensive study on contemporary portable wind energy harvesters has been conducted. The electrical power generation methods of portable wind energy harvesters are surveyed in three major groups, piezoelectric-, electromagnetic-, and electrostatic-based generators. The paper also takes another view of this area by gauging the required mechanisms for trapping wind flow from ambient environment. In this regard, rotational and aeroelastic mechanisms are analyzed for the portable wind energy harvesting devices. The comparison between both mechanisms shows that the aeroelastic mechanism has promising potential in producing an energy harvester in smaller scale although how to maintain the resonator perpendicular to wind flow for collecting the maximum vibration is still a major challenge to overcome for this mechanism. Furthermore, this paper categorizes the previously published portable wind energy harvesters to macro and micro scales in terms of their physical dimensions. The power management systems are also surveyed to explore the possibility of improving energy conversion efficiency. Finally some insights and research trends are pointed out based on an overall analysis of the previously published works along the historical timeline.

  13. Coleman performs VO2 Max PFS Software Calibrations and Instrument Check

    NASA Image and Video Library

    2011-02-24

    ISS026-E-029180 (24 Feb. 2011) --- NASA astronaut Catherine (Cady) Coleman, Expedition 26 flight engineer, performs VO2max portable Pulmonary Function System (PFS) software calibrations and instrument check while using the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.

  14. A method to identify the main mode of machine tool under operating conditions

    NASA Astrophysics Data System (ADS)

    Wang, Daming; Pan, Yabing

    2017-04-01

    The identification of the modal parameters under experimental conditions is the most common procedure when solving the problem of machine tool structure vibration. However, the influence of each mode on the machine tool vibration in real working conditions remains unknown. In fact, the contributions each mode makes to the machine tool vibration during machining process are different. In this article, an active excitation modal analysis is applied to identify the modal parameters in operational condition, and the Operating Deflection Shapes (ODS) in frequencies of high level vibration that affect the quality of machining in real working conditions are obtained. Then, the ODS is decomposed by the mode shapes which are identified in operational conditions. So, the contributions each mode makes to machine tool vibration during machining process are got by decomposition coefficients. From the previous steps, we can find out the main modes which effect the machine tool more significantly in working conditions. This method was also verified to be effective by experiments.

  15. Vibration damping method and apparatus

    DOEpatents

    Redmond, James M.; Barney, Patrick S.; Parker, Gordon G.; Smith, David A.

    1999-01-01

    The present invention provides vibration damping method and apparatus that can damp vibration in more than one direction without requiring disassembly, that can accommodate varying tool dimensions without requiring re-tuning, and that does not interfere with tool tip operations and cooling. The present invention provides active dampening by generating bending moments internal to a structure such as a boring bar to dampen vibration thereof.

  16. On-line tool breakage monitoring of vibration tapping using spindle motor current

    NASA Astrophysics Data System (ADS)

    Li, Guangjun; Lu, Huimin; Liu, Gang

    2008-10-01

    Input current of driving motor has been employed successfully as monitoring the cutting state in manufacturing processes for more than a decade. In vibration tapping, however, the method of on-line monitoring motor electric current has not been reported. In this paper, a tap failure prediction method is proposed to monitor the vibration tapping process using the electrical current signal of the spindle motor. The process of vibration tapping is firstly described. Then the relationship between the torque of vibration tapping and the electric current of motor is investigated by theoretic deducing and experimental measurement. According to those results, a monitoring method of tool's breakage is proposed through monitoring the ratio of the current amplitudes during adjacent vibration tapping periods. Finally, a low frequency vibration tapping system with motor current monitoring is built up using a servo motor B-106B and its driver CR06. The proposed method has been demonstrated with experiment data of vibration tapping in titanic alloys. The result of experiments shows that the method, which can avoid the tool breakage and giving a few error alarms when the threshold of amplitude ratio is 1.2 and there is at least 2 times overrun among 50 adjacent periods, is feasible for tool breakage monitoring in the process of vibration tapping small thread holes.

  17. Digital vibration threshold testing and ergonomic stressors in automobile manufacturing workers: a cross-sectional assessment.

    PubMed

    Gold, J E; Punnett, L; Cherniack, M; Wegman, D H

    2005-01-01

    Upper extremity musculoskeletal disorders (UEMSDs) comprise a large proportion of work-related illnesses in the USA. Physical risk factors including manual force and segmental vibration have been associated with UEMSDs. Reduced sensitivity to vibration in the fingertips (a function of nerve integrity) has been found in those exposed to segmental vibration, to hand force, and in office workers. The objective of this study was to determine whether an association exists between digital vibration thresholds (VTs) and exposure to ergonomic stressors in automobile manufacturing. Interviews and physical examinations were conducted in a cross-sectional survey of workers (n = 1174). In multivariable robust regression modelling, associations with workers' estimates of ergonomic stressors stratified on tool use were determined. VTs were separately associated with hand force, vibration as felt through the floor (whole body vibration), and with an index of multiple exposures in both tool users and non-tool users. Additional associations with contact stress and awkward upper extremity postures were found in tool users. Segmental vibration was not associated with VTs. Further epidemiologic and laboratory studies are needed to confirm the associations found. The association with self-reported whole body vibration exposure suggests a possible sympathetic nervous system effect, which remains to be explored.

  18. Evaluation of hand-arm and whole-body vibrations in construction and property management.

    PubMed

    Coggins, Marie A; Van Lente, Eric; McCallig, Margaret; Paddan, Gurmail; Moore, Ken

    2010-11-01

    To identify and measure the magnitude of hand-arm vibration (HAV) and whole-body vibration (WBV) sources (tools, vehicles etc.) in use within a previously unexamined sector: a construction and property management company. To evaluate the effect of factors such as age of tool, materials being worked on, number and location of tool handles, tool weight, and manufacturer brand on HAV magnitude and the effect of factors such as manufacturer machine brand, terrain, and work task on WBV magnitude. This study was carried out in a construction and property management company, employees (n = 469) working in the engineering services and maintenance departments who use vibrating equipment as part of their work were invited to participate. Two hundred and eighty-nine employees working as general operatives, excavator drivers, stone masons, carpenters, labourers, fitters, welders, and gardeners agreed to participate. A total of 20 types of hand tool (n = 264) and 11 types of vehicle (n = 158) in use within the company were selected for inclusion in the study. Five pieces of equipment had never previously been measured. Vibration measurements were carried out in accordance with ISO 5349-1 (Mechanical vibration-measurement and assessment of human exposure to hand transmitted vibration-Part 1: general guidance. 2001) (HAV) and ISO 2631-1 (Mechanical vibration and shock: evaluation of human exposure to WBV in the working environment. Part 1-general requirements. 1997) (WBV). Vibration measurements were made while workers were operating the equipment as part of their normal work activities. A wide range of vibration emission values were recorded for most tool types, e.g. orbital sanders (1.39-10.90 m s⁻²) and angle grinders (0.28-12.25 m s⁻²), and vehicle, e.g. forklifts (0.41-1.00 m s⁻²) and tractors (0.04-0.42 m s⁻²). Vibration magnitudes were largely consistent with those found in previous studies. The highest HAV magnitude was measured on a demolition hammer (13.3 m s⁻²) and the highest WBV magnitudes were measured on an excavator with a rock breaking attachment (5.81 m s⁻²). HAV magnitudes were found to be particularly strongly influenced by tool age, while WBV magnitudes varied with work activity and terrain. Within the construction and management company, few hand tools (3 of 20) exceeded the exposure action values (EAV) specified in the European Physical Agents (Vibration) Directive 2002/44/EC [On the minimum health and safety requirements regarding the exposure of works to the risks arising form physical agents (vibration)], when used for an 8-h period. HAV magnitudes were found to be very dependent on tool age, highlighting the importance of a tool maintenance programme incorporating tool work life prediction supported by regular vibration exposure measurements. Most of the vehicles (10 of 11) tested in this study exceeded the EAV specified for WBV, when operated for 8 h. WBV magnitudes were found to be dependent on the work task and thus, job rotation could be employed to control WBV exposures to acceptable levels.

  19. [The combined use of capillaroscopy and skin thermometry in health surveillance of workers exposed to hand-arm vibration].

    PubMed

    Riolfi, A; Perbellini, L

    2010-01-01

    The use of nailfold capillaroscopy combined with skin thermometry in the study of microcirculation of the hands in workers exposed to hand-arm vibration is assessed. Fifty-eight subjects were studied; 40 asymptomatic forestry workers exposed to hand-arm vibration, 13 forestry workers exposed to hand-arm vibration with Raynaud-like symptoms confirmed by skin thermometry; 5 controls. Reduction of capillary density was observed in workers exposed to vibrating tools with respect to controls. Tortuosity of capillary loops was significantly more frequent in subjects exposed to vibrating tools than in controls. No statistically significant difference in capillary vessels of the hands was found between asymptomatic exposed subjects and workers affected by Raynaud-like symptoms. In our sample nailfold capillaroscopy shows good sensibilty and specificity in detecting capillary modifications secondary to exposure to hand-vibration. Weaker evidence is instead given in order to actual disturbances of hands circulation in chronic exposure to vibrating tools.

  20. Remote vibration monitoring system using wireless internet data transfer

    NASA Astrophysics Data System (ADS)

    Lemke, John

    2000-06-01

    Vibrations from construction activities can affect infrastructure projects in several ways. Within the general vicinity of a construction site, vibrations can result in damage to existing structures, disturbance to people, damage to sensitive machinery, and degraded performance of precision instrumentation or motion sensitive equipment. Current practice for monitoring vibrations in the vicinity of construction sites commonly consists of measuring free field or structural motions using velocity transducers connected to a portable data acquisition unit via cables. This paper describes an innovative way to collect, process, transmit, and analyze vibration measurements obtained at construction sites. The system described measures vibration at the sensor location, performs necessary signal conditioning and digitization, and sends data to a Web server using wireless data transmission and Internet protocols. A Servlet program running on the Web server accepts the transmitted data and incorporates it into a project database. Two-way interaction between the Web-client and the Web server is accomplished through the use of a Servlet program and a Java Applet running inside a browser located on the Web client's computer. Advantages of this system over conventional vibration data logging systems include continuous unattended monitoring, reduced costs associated with field data collection, instant access to data files and graphs by project team members, and the ability to remotely modify data sampling schemes.

  1. Vibration damping method and apparatus

    DOEpatents

    Redmond, J.M.; Barney, P.S.; Parker, G.G.; Smith, D.A.

    1999-06-22

    The present invention provides vibration damping method and apparatus that can damp vibration in more than one direction without requiring disassembly, that can accommodate varying tool dimensions without requiring re-tuning, and that does not interfere with tool tip operations and cooling. The present invention provides active dampening by generating bending moments internal to a structure such as a boring bar to dampen vibration thereof. 38 figs.

  2. Hand-arm vibration syndrome: a common occupational hazard in industrialized countries.

    PubMed

    Heaver, C; Goonetilleke, K S; Ferguson, H; Shiralkar, S

    2011-06-01

    Regular exposure to hand-transmitted vibration can result in symptoms and signs of peripheral vascular, neurological and other disorders collectively known as the hand-arm vibration syndrome (HAVS). A significant proportion of workers can suffer from HAVS after using vibrating power tools. HAVS is a chronic and progressive disorder. Early recognition and prevention is the key to managing vibrating tool exposures and health effects. This article gives a broad overview of the condition with a detailed account of its pathogenesis, identification and management.

  3. Vibration-tolerant narrow-linewidth semiconductor disk laser using novel frequency-stabilisation schemes

    NASA Astrophysics Data System (ADS)

    Hunter, Craig R.; Jones, Brynmor E.; Schlosser, Peter; Sørensen, Simon Toft; Strain, Michael J.; McKnight, Loyd J.

    2018-02-01

    This paper will present developments in narrow-linewidth semiconductor-disk-laser systems using novel frequencystabilisation schemes for reduced sensitivity to mechanical vibrations, a critical requirement for mobile applications. Narrow-linewidth single-frequency lasers are required for a range of applications including metrology and highresolution spectroscopy. Stabilisation of the laser was achieved using a monolithic fibre-optic ring resonator with free spectral range of 181 MHz and finesse of 52 to act as passive reference cavity for the laser. Such a cavity can operate over a broad wavelength range and is immune to a wide band of vibrational frequency noise due to its monolithic implementation. The frequency noise of the locked system has been measured and compared to typical Fabry-Perotlocked lasers using vibration equipment to simulate harsh environments, and analysed here. Locked linewidths of < 40 kHz have been achieved. These developments offer a portable, narrow-linewidth laser system for harsh environments that can be flexibly designed for a range of applications.

  4. Portable Radiation Detectors

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Through a Small Business Innovation Research (SBIR) contract from Kennedy Space Center, General Pneumatics Corporation's Western Research Center satisfied a NASA need for a non-clogging Joule-Thomson cryostat to provide very low temperature cooling for various sensors. This NASA-supported cryostat development played a key part in the development of more portable high-purity geranium gamma-ray detectors. Such are necessary to discern between the radionuclides in medical, fuel, weapon, and waste materials. The outcome of the SBIR project is a cryostat that can cool gamma-ray detectors, without vibration, using compressed gas that can be stored compactly and indefinitely in a standby mode. General Pneumatics also produces custom J-T cryostats for other government, commercial and medical applications.

  5. Fatigue Analysis of Proton Exchange Membrane Fuel Cell Stacks Based on Structural Stress Distribution

    NASA Astrophysics Data System (ADS)

    Wu, C. W.; Liu, B.; Wei, M. Y.; Liu, L. F.

    2017-05-01

    Proton exchange membrane fuel cell (PEMFC) stack usually undergoes various vibrations during packing, transportation and serving time, in particular for those used in the automobiles and portable equipment. Based on the Miner fatigue damage theory, the fatigue lives of the fuel cell components are first assessed. Then the component fatigue life contours of the stack are obtained under four working conditions, i.e. the three single-axial (in X-, Y- and Z-axis separately) and multi-axial random vibrations. Accordingly, the component damage under various vibrations is evaluated. The stress distribution on the gasket and PEM will greatly affect their fatigue lives. Finally, we compare the fatigue lives of 4-bolt- and 6-bolt-clamping stacks under the same total clamping force, and find that increasing the bolt number could improve the bolt fatigue lives.

  6. Open environments to support systems engineering tool integration: A study using the Portable Common Tool Environment (PCTE)

    NASA Technical Reports Server (NTRS)

    Eckhardt, Dave E., Jr.; Jipping, Michael J.; Wild, Chris J.; Zeil, Steven J.; Roberts, Cathy C.

    1993-01-01

    A study of computer engineering tool integration using the Portable Common Tool Environment (PCTE) Public Interface Standard is presented. Over a 10-week time frame, three existing software products were encapsulated to work in the Emeraude environment, an implementation of the PCTE version 1.5 standard. The software products used were a computer-aided software engineering (CASE) design tool, a software reuse tool, and a computer architecture design and analysis tool. The tool set was then demonstrated to work in a coordinated design process in the Emeraude environment. The project and the features of PCTE used are described, experience with the use of Emeraude environment over the project time frame is summarized, and several related areas for future research are summarized.

  7. Vibration syndrome in railway track maintenance workers.

    PubMed

    Virokannas, H; Anttonen, H; Niskanen, J

    1995-01-01

    An inquiry was sent to all railway maintenance workers in three railway districts in Finland and hand-arm vibration was measured on the handlebars of tools used by maintenance workers. The study group included 252 (82%) subjects, whose mean age was 41 years and who had worked in track maintenance for 14 years (SD 9). In Finland there are over 600 railway maintenance workers who use vibrating tools. The frequency-weighted acceleration of hand-arm vibration was calculated according to the ISO 5349 standard. Hand-held tamping machines had caused most of the vibration exposure, and aw4h was 10.6 m/s2 measured on the handlebar of tamping machine, but many workers also used other vibrating tools. The annual vibration level was 2.5 m/s2 when the use of all vibrating tools and the exposure time was taken into account. In the questionnaire the prevalence of vibration-induced white finger (VWF) was 14% in the entire material, and the prevalence of VWF increased significantly with the total duration of the maintenance work. In addition, 39% of the subjects had suffered numbness of the hands, and the prevalence of hand numbness also increased significantly with the total duration of maintenance work. According to the measurements of vibration and the prevalence of hand symptoms the present investigation indicates vibration syndrome as being related to railway track maintenance work. In the exposure group, where tamping machines mainly were used and exposure to other vibration was small, the prevalence of VWF was also significantly higher, but the prevalence of hand numbness insignificant compared with the control group. In this study vascular and nerve hand symptoms were considered to cause serious trouble in work by 4-11% of the maintenance workers.

  8. Application and Miniaturization of Linear and Nonlinear Raman Microscopy for Biomedical Imaging

    NASA Astrophysics Data System (ADS)

    Mittal, Richa

    Current diagnostics for several disorders rely on surgical biopsy or evaluation of ex vivo bodily fluids, which have numerous drawbacks. We evaluated the potential for vibrational techniques (both linear and nonlinear Raman) as a reliable and noninvasive diagnostic tool. Raman spectroscopy is an optical technique for molecular analysis that has been used extensively in various biomedical applications. Based on demonstrated capabilities of Raman spectroscopy we evaluated the potential of the technique for providing a noninvasive diagnosis of mucopolysaccharidosis (MPS). These studies show that Raman spectroscopy can detect subtle changes in tissue biochemistry. In applications where sub-micrometer visualization of tissue compositional change is required, a transition from spectroscopy to high quality imaging is necessary. Nonlinear vibrational microscopy is sensitive to the same molecular vibrations as linear Raman, but features fast imaging capabilities. Coherent Raman scattering when combined with other nonlinear optical (NLO) techniques (like two-photon excited fluorescence and second harmonic generation) forms a collection of advanced optical techniques that provide noninvasive chemical contrast at submicron resolution. This capability to examine tissues without external molecular agents is driving the NLO approach towards clinical applications. However, the unique imaging capabilities of NLO microscopy are accompanied by complex instrument requirements. Clinical examination requires portable imaging systems for rapid inspection of tissues. Optical components utilized in NLO microscopy would then need substantial miniaturization and optimization to enable in vivo use. The challenges in designing compact microscope objective lenses and laser beam scanning mechanisms are discussed. The development of multimodal NLO probes for imaging oral cavity tissue is presented. Our prototype has been examined for ex vivo tissue imaging based on intrinsic fluorescence and SHG contrast. These studies show a potential for multiphoton compact probes to be used for real time imaging in the clinic.

  9. A portable toolbox to monitor and evaluate signal operations.

    DOT National Transportation Integrated Search

    2011-10-01

    Researchers from the Texas Transportation Institute developed a portable tool consisting of a fieldhardened : computer interfacing with the traffic signal cabinet through special enhanced Bus Interface Units. : The toolbox consisted of a monitoring t...

  10. Multilayer modal actuator-based piezoelectric transformers.

    PubMed

    Huang, Yao-Tien; Wu, Wen-Jong; Wang, Yen-Chieh; Lee, Chih-Kung

    2007-02-01

    An innovative, multilayer piezoelectric transformer equipped with a full modal filtering input electrode is reported herein. This modal-shaped electrode, based on the orthogonal property of structural vibration modes, is characterized by full modal filtering to ensure that only the desired vibration mode is excited during operation. The newly developed piezoelectric transformer is comprised of three layers: a multilayered input layer, an insulation layer, and a single output layer. The electrode shape of the input layer is derived from its structural vibration modal shape, which takes advantage of the orthogonal property of the vibration modes to achieve a full modal filtering effect. The insulation layer possesses two functions: first, to couple the mechanical vibration energy between the input and output, and second, to provide electrical insulation between the two layers. To meet the two functions, a low temperature, co-fired ceramic (LTCC) was used to provide the high mechanical rigidity and high electrical insulation. It can be shown that this newly developed piezoelectric transformer has the advantage of possessing a more efficient energy transfer and a wider optimal working frequency range when compared to traditional piezoelectric transformers. A multilayer piezoelectric, transformer-based inverter applicable for use in LCD monitors or portable displays is presented as well.

  11. A portable borehole temperature logging system using the four-wire resistance method

    NASA Astrophysics Data System (ADS)

    Erkan, Kamil; Akkoyunlu, Bülent; Balkan, Elif; Tayanç, Mete

    2017-12-01

    High-quality temperature-depth information from boreholes with a depth of 100 m or more is used in geothermal studies and in studies of climate change. Electrical wireline tools with thermistor sensors are capable of measuring borehole temperatures with millikelvin resolution. The use of a surface readout mode allows analysis of the thermally conductive state of a borehole, which is especially important for climatic and regional heat flow studies. In this study we describe the design of a portable temperature logging tool that uses the four-wire resistance measurement method. The four-wire method enables the elimination of cable resistance effects, thus allowing millikelvin resolution of temperature data at depth. A preliminary two-wire model of the system is also described. The portability of the tool enables one to collect data from boreholes down to 300 m, even in locations with limited accessibility.

  12. Programming Tools: Status, Evaluation, and Comparison

    NASA Technical Reports Server (NTRS)

    Cheng, Doreen Y.; Cooper, D. M. (Technical Monitor)

    1994-01-01

    In this tutorial I will first describe the characteristics of scientific applications and their developers, and describe the computing environment in a typical high-performance computing center. I will define the user requirements for tools that support application portability and present the difficulties to satisfy them. These form the basis of the evaluation and comparison of the tools. I will then describe the tools available in the market and the tools available in the public domain. Specifically, I will describe the tools for converting sequential programs, tools for developing portable new programs, tools for debugging and performance tuning, tools for partitioning and mapping, and tools for managing network of resources. I will introduce the main goals and approaches of the tools, and show main features of a few tools in each category. Meanwhile, I will compare tool usability for real-world application development and compare their different technological approaches. Finally, I will indicate the future directions of the tools in each category.

  13. Statistical quality control through overall vibration analysis

    NASA Astrophysics Data System (ADS)

    Carnero, M. a. Carmen; González-Palma, Rafael; Almorza, David; Mayorga, Pedro; López-Escobar, Carlos

    2010-05-01

    The present study introduces the concept of statistical quality control in automotive wheel bearings manufacturing processes. Defects on products under analysis can have a direct influence on passengers' safety and comfort. At present, the use of vibration analysis on machine tools for quality control purposes is not very extensive in manufacturing facilities. Noise and vibration are common quality problems in bearings. These failure modes likely occur under certain operating conditions and do not require high vibration amplitudes but relate to certain vibration frequencies. The vibration frequencies are affected by the type of surface problems (chattering) of ball races that are generated through grinding processes. The purpose of this paper is to identify grinding process variables that affect the quality of bearings by using statistical principles in the field of machine tools. In addition, an evaluation of the quality results of the finished parts under different combinations of process variables is assessed. This paper intends to establish the foundations to predict the quality of the products through the analysis of self-induced vibrations during the contact between the grinding wheel and the parts. To achieve this goal, the overall self-induced vibration readings under different combinations of process variables are analysed using statistical tools. The analysis of data and design of experiments follows a classical approach, considering all potential interactions between variables. The analysis of data is conducted through analysis of variance (ANOVA) for data sets that meet normality and homoscedasticity criteria. This paper utilizes different statistical tools to support the conclusions such as chi squared, Shapiro-Wilks, symmetry, Kurtosis, Cochran, Hartlett, and Hartley and Krushal-Wallis. The analysis presented is the starting point to extend the use of predictive techniques (vibration analysis) for quality control. This paper demonstrates the existence of predictive variables (high-frequency vibration displacements) that are sensible to the processes setup and the quality of the products obtained. Based on the result of this overall vibration analysis, a second paper will analyse self-induced vibration spectrums in order to define limit vibration bands, controllable every cycle or connected to permanent vibration-monitoring systems able to adjust sensible process variables identified by ANOVA, once the vibration readings exceed established quality limits.

  14. Method and apparatus for suppressing regenerative instability and related chatter in machine tools

    DOEpatents

    Segalman, Daniel J.; Redmond, James M.

    2001-01-01

    Methods of and apparatuses for mitigating chatter vibrations in machine tools or components thereof. Chatter therein is suppressed by periodically or continuously varying the stiffness of the cutting tool (or some component of the cutting tool), and hence the resonant frequency of the cutting tool (or some component thereof). The varying of resonant frequency of the cutting tool can be accomplished by modulating the stiffness of the cutting tool, the cutting tool holder, or any other component of the support for the cutting tool. By periodically altering the impedance of the cutting tool assembly, chatter is mitigated. In one embodiment, a cyclic electric (or magnetic) field is applied to the spindle quill which contains an electro-rheological (or magneto-rheological) fluid. The variable yield stress in the fluid affects the coupling of the spindle to the machine tool structure, changing the natural frequency of oscillation. Altering the modal characteristics in this fashion disrupts the modulation of current tool vibrations with previous tool vibrations recorded on the workpiece surface.

  15. Method and apparatus for suppressing regenerative instability and related chatter in machine tools

    DOEpatents

    Segalman, Daniel J.; Redmond, James M.

    1999-01-01

    Methods of and apparatuses for mitigating chatter vibrations in machine tools or components thereof. Chatter therein is suppressed by periodically or continuously varying the stiffness of the cutting tool (or some component of the cutting tool), and hence the resonant frequency of the cutting tool (or some component thereof). The varying of resonant frequency of the cutting tool can be accomplished by modulating the stiffness of the cutting tool, the cutting tool holder, or any other component of the support for the cutting tool. By periodically altering the impedance of the cutting tool assembly, chatter is mitigated. In one embodiment, a cyclic electric (or magnetic) field is applied to the spindle quill which contains an electro-rheological (or magneto-rheological) fluid. The variable yield stress in the fluid affects the coupling of the spindle to the machine tool structure, changing the natural frequency of oscillation. Altering the modal characteristics in this fashion disrupts the modulation of current tool vibrations with previous tool vibrations recorded on the workpiece surface.

  16. Balancing Vanguard Satellites

    NASA Technical Reports Server (NTRS)

    Simkovich, A.; Baumann, Robert C.

    1961-01-01

    The Vanguard satellites and component parts were balanced within the specified limits by using a Gisholt Type-S balancer in combination with a portable International Research and Development vibration analyzer and filter, with low-frequency pickups. Equipment and procedures used for balancing are described; and the determination of residual imbalance is accomplished by two methods: calculation, and graphical interpretation. Between-the-bearings balancing is recommended for future balancing of payloads.

  17. Real-Time Performance of Mechatronic PZT Module Using Active Vibration Feedback Control.

    PubMed

    Aggogeri, Francesco; Borboni, Alberto; Merlo, Angelo; Pellegrini, Nicola; Ricatto, Raffaele

    2016-09-25

    This paper proposes an innovative mechatronic piezo-actuated module to control vibrations in modern machine tools. Vibrations represent one of the main issues that seriously compromise the quality of the workpiece. The active vibration control (AVC) device is composed of a host part integrated with sensors and actuators synchronized by a regulator; it is able to make a self-assessment and adjust to alterations in the environment. In particular, an innovative smart actuator has been designed and developed to satisfy machining requirements during active vibration control. This study presents the mechatronic model based on the kinematic and dynamic analysis of the AVC device. To ensure a real time performance, a H2-LQG controller has been developed and validated by simulations involving a machine tool, PZT actuator and controller models. The Hardware in the Loop (HIL) architecture is adopted to control and attenuate the vibrations. A set of experimental tests has been performed to validate the AVC module on a commercial machine tool. The feasibility of the real time vibration damping is demonstrated and the simulation accuracy is evaluated.

  18. Real-Time Performance of Mechatronic PZT Module Using Active Vibration Feedback Control

    PubMed Central

    Aggogeri, Francesco; Borboni, Alberto; Merlo, Angelo; Pellegrini, Nicola; Ricatto, Raffaele

    2016-01-01

    This paper proposes an innovative mechatronic piezo-actuated module to control vibrations in modern machine tools. Vibrations represent one of the main issues that seriously compromise the quality of the workpiece. The active vibration control (AVC) device is composed of a host part integrated with sensors and actuators synchronized by a regulator; it is able to make a self-assessment and adjust to alterations in the environment. In particular, an innovative smart actuator has been designed and developed to satisfy machining requirements during active vibration control. This study presents the mechatronic model based on the kinematic and dynamic analysis of the AVC device. To ensure a real time performance, a H2-LQG controller has been developed and validated by simulations involving a machine tool, PZT actuator and controller models. The Hardware in the Loop (HIL) architecture is adopted to control and attenuate the vibrations. A set of experimental tests has been performed to validate the AVC module on a commercial machine tool. The feasibility of the real time vibration damping is demonstrated and the simulation accuracy is evaluated. PMID:27681732

  19. Hand-arm vibration syndrome from exposure to high-pressure hoses.

    PubMed

    Cooke, R; House, R; Lawson, I J; Pelmear, P L; Wills, M

    2001-09-01

    Hand-arm vibration syndrome has been reported in the literature to occur following exposure to vibration from the use of many tools, but to date there have been no case reports of its occurrence in workers who have used high-pressure hoses, alone or with other tools. To remedy this, the case histories of nine subjects (two without mixed exposure) examined in the UK and Canada are presented, together with their severity classified according to the Stockholm scales. Attention is drawn to the need to use multiple diagnostic tests to establish the diagnosis and the need to implement vibration isolation and damping methodologies, as and when feasible, with respect to hose nozzles in order to minimize the hazard. The ultimate goal for tool manufacturers, hygienists and engineers should be to reduce workplace vibration levels to meet national and international guidelines and legislation, including UK Health & Safety Executive guidelines and European Economic Community directives. The respective risk levels are presented, together with vibration measurements on hoses used by some of the cases.

  20. Integrating Oil Debris and Vibration Measurements for Intelligent Machine Health Monitoring. Degree awarded by Toledo Univ., May 2002

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.

    2003-01-01

    A diagnostic tool for detecting damage to gears was developed. Two different measurement technologies, oil debris analysis and vibration were integrated into a health monitoring system for detecting surface fatigue pitting damage on gears. This integrated system showed improved detection and decision-making capabilities as compared to using individual measurement technologies. This diagnostic tool was developed and evaluated experimentally by collecting vibration and oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Rig. An oil debris sensor and the two vibration algorithms were adapted as the diagnostic tools. An inductance type oil debris sensor was selected for the oil analysis measurement technology. Gear damage data for this type of sensor was limited to data collected in the NASA Glenn test rigs. For this reason, this analysis included development of a parameter for detecting gear pitting damage using this type of sensor. The vibration data was used to calculate two previously available gear vibration diagnostic algorithms. The two vibration algorithms were selected based on their maturity and published success in detecting damage to gears. Oil debris and vibration features were then developed using fuzzy logic analysis techniques, then input into a multi sensor data fusion process. Results show combining the vibration and oil debris measurement technologies improves the detection of pitting damage on spur gears. As a result of this research, this new diagnostic tool has significantly improved detection of gear damage in the NASA Glenn Spur Gear Fatigue Rigs. This research also resulted in several other findings that will improve the development of future health monitoring systems. Oil debris analysis was found to be more reliable than vibration analysis for detecting pitting fatigue failure of gears and is capable of indicating damage progression. Also, some vibration algorithms are as sensitive to operational effects as they are to damage. Another finding was that clear threshold limits must be established for diagnostic tools. Based on additional experimental data obtained from the NASA Glenn Spiral Bevel Gear Fatigue Rig, the methodology developed in this study can be successfully implemented on other geared systems.

  1. Light weight, high-speed, and self-powered wireless fiber optic sensor (WiFOS) structural health monitor system for avionics and aerospace environments

    NASA Astrophysics Data System (ADS)

    Mendoza, Edgar A.; Kempen, Cornelia; Sun, Sunjian; Esterkin, Yan

    2014-09-01

    This paper describes recent progress towards the development of an innovative light weight, high-speed, and selfpowered wireless fiber optic sensor (WiFOS™) structural health monitor system suitable for the onboard and in-flight unattended detection, localization, and classification of load, fatigue, and structural damage in advanced composite materials commonly used in avionics and aerospace systems. The WiFOS™ system is based on ROI's advancements on monolithic photonic integrated circuit microchip technology, integrated with smart power management, on-board data processing, wireless data transmission optoelectronics, and self-power using energy harvesting tools such as solar, vibration, thermoelectric, and magneto-electric. The self-powered, wireless WiFOS™ system offers a versatile and powerful SHM tool to enhance the reliability and safety of avionics platforms, jet fighters, helicopters, commercial aircraft that use lightweight composite material structures, by providing comprehensive information about the structural integrity of the structure from a large number of locations. Immediate SHM applications are found in rotorcraft and aircraft, ships, submarines, and in next generation weapon systems, and in commercial oil and petrochemical, aerospace industries, civil structures, power utilities, portable medical devices, and biotechnology, homeland security and a wide spectrum of other applications.

  2. Coupled rotor/airframe vibration analysis

    NASA Technical Reports Server (NTRS)

    Sopher, R.; Studwell, R. E.; Cassarino, S.; Kottapalli, S. B. R.

    1982-01-01

    A coupled rotor/airframe vibration analysis developed as a design tool for predicting helicopter vibrations and a research tool to quantify the effects of structural properties, aerodynamic interactions, and vibration reduction devices on vehicle vibration levels is described. The analysis consists of a base program utilizing an impedance matching technique to represent the coupled rotor/airframe dynamics of the system supported by inputs from several external programs supplying sophisticated rotor and airframe aerodynamic and structural dynamic representation. The theoretical background, computer program capabilities and limited correlation results are presented in this report. Correlation results using scale model wind tunnel results show that the analysis can adequately predict trends of vibration variations with airspeed and higher harmonic control effects. Predictions of absolute values of vibration levels were found to be very sensitive to modal characteristics and results were not representative of measured values.

  3. Built-up edge investigation in vibration drilling of Al2024-T6.

    PubMed

    Barani, A; Amini, S; Paktinat, H; Fadaei Tehrani, A

    2014-07-01

    Adding ultrasonic vibrations to drilling process results in an advanced hybrid machining process, entitled "vibration drilling". This study presents the design and fabrication of a vibration drilling tool by which both rotary and vibrating motions are applied to drill simultaneously. High frequency and low amplitude vibrations were generated by an ultrasonic transducer with frequency of 19.65 kHz. Ultrasonic transducer was controlled by a MPI ultrasonic generator with 3 kW power. The drilling tool and workpiece material were HSS two-flute twist drill and Al2024-T6, respectively. The aim of this study was investigating on the effect of ultrasonic vibrations on built-up edge, surface quality, chip morphology and wear mechanisms of drill edges. Therefore, these factors were studied in both vibration and ordinary drilling. Based on the achieved results, vibration drilling offers less built-up edge and better surface quality compared to ordinary drilling. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. ShakeNet: a portable wireless sensor network for instrumenting large civil structures

    USGS Publications Warehouse

    Kohler, Monica D.; Hao, Shuai; Mishra, Nilesh; Govindan, Ramesh; Nigbor, Robert

    2015-08-03

    We report our findings from a U.S. Geological Survey (USGS) National Earthquake Hazards Reduction Program-funded project to develop and test a wireless, portable, strong-motion network of up to 40 triaxial accelerometers for structural health monitoring. The overall goal of the project was to record ambient vibrations for several days from USGS-instrumented structures. Structural health monitoring has important applications in fields like civil engineering and the study of earthquakes. The emergence of wireless sensor networks provides a promising means to such applications. However, while most wireless sensor networks are still in the experimentation stage, very few take into consideration the realistic earthquake engineering application requirements. To collect comprehensive data for structural health monitoring for civil engineers, high-resolution vibration sensors and sufficient sampling rates should be adopted, which makes it challenging for current wireless sensor network technology in the following ways: processing capabilities, storage limit, and communication bandwidth. The wireless sensor network has to meet expectations set by wired sensor devices prevalent in the structural health monitoring community. For this project, we built and tested an application-realistic, commercially based, portable, wireless sensor network called ShakeNet for instrumentation of large civil structures, especially for buildings, bridges, or dams after earthquakes. Two to three people can deploy ShakeNet sensors within hours after an earthquake to measure the structural response of the building or bridge during aftershocks. ShakeNet involved the development of a new sensing platform (ShakeBox) running a software suite for networking, data collection, and monitoring. Deployments reported here on a tall building and a large dam were real-world tests of ShakeNet operation, and helped to refine both hardware and software. 

  5. Software Tools to Support Research on Airport Departure Planning

    NASA Technical Reports Server (NTRS)

    Carr, Francis; Evans, Antony; Feron, Eric; Clarke, John-Paul

    2003-01-01

    A simple, portable and useful collection of software tools has been developed for the analysis of airport surface traffic. The tools are based on a flexible and robust traffic-flow model, and include calibration, validation and simulation functionality for this model. Several different interfaces have been developed to help promote usage of these tools, including a portable Matlab(TM) implementation of the basic algorithms; a web-based interface which provides online access to automated analyses of airport traffic based on a database of real-world operations data which covers over 250 U.S. airports over a 5-year period; and an interactive simulation-based tool currently in use as part of a college-level educational module. More advanced applications for airport departure traffic include taxi-time prediction and evaluation of "windowing" congestion control.

  6. AN IMPROVED PORTABLE SURGICAL TABLE FOR THE FIELD AND LABORATORY

    EPA Science Inventory

    I substantially modified a portable surgical table design by Courtois (1981) to increase its durability and utility. The new design incorporated durable plastic components, a nonskid neoprene surgery surface, and surgical tool bins. The system was used to implant fish and amphibi...

  7. On-Site Molecular Detection of Soil-Borne Phytopathogens Using a Portable Real-Time PCR System

    PubMed Central

    DeShields, Joseph B.; Bomberger, Rachel A.; Woodhall, James W.; Wheeler, David L.; Moroz, Natalia; Johnson, Dennis A.; Tanaka, Kiwamu

    2018-01-01

    On-site diagnosis of plant diseases can be a useful tool for growers for timely decisions enabling the earlier implementation of disease management strategies that reduce the impact of the disease. Presently in many diagnostic laboratories, the polymerase chain reaction (PCR), particularly real-time PCR, is considered the most sensitive and accurate method for plant pathogen detection. However, laboratory-based PCRs typically require expensive laboratory equipment and skilled personnel. In this study, soil-borne pathogens of potato are used to demonstrate the potential for on-site molecular detection. This was achieved using a rapid and simple protocol comprising of magnetic bead-based nucleic acid extraction, portable real-time PCR (fluorogenic probe-based assay). The portable real-time PCR approach compared favorably with a laboratory-based system, detecting as few as 100 copies of DNA from Spongospora subterranea. The portable real-time PCR method developed here can serve as an alternative to laboratory-based approaches and a useful on-site tool for pathogen diagnosis. PMID:29553557

  8. Effect of magneto rheological damper on tool vibration during hard turning

    NASA Astrophysics Data System (ADS)

    Paul, P. Sam; Varadarajan, A. S.

    2012-12-01

    Recently, the concept of hard turning has gained considerable attention in metal cutting as it can apparently replace the traditional process cycle of turning, heat treating, and finish grinding for assembly of hard wear resistant steel parts. The present investigation aims at developing a magneto rheological (MR) fluid damper for suppressing tool vibration and promoting better cutting performance during hard turning. The magneto rheological Fluid acts as a viscoelastic spring with non-linear vibration characteristics that are controlled by the composition of the magneto rheological fluid, the shape of the plunger and the electric parameters of the magnetizing field. Cutting experiments were conducted to arrive at a set of electrical, compositional and shape parameters that can suppress tool vibration and promote better cutting performance during turning of AISI 4340 steel of 46 HRC with minimal fluid application using hard metal insert with sculptured rake face. It was observed that the use of MR fluid damper reduces tool vibration and improves the cutting performance effectively. Also commercialization of this idea holds promise to the metal cutting industry.

  9. Pettit exercises on the CEVIS

    NASA Image and Video Library

    2012-03-07

    ISS030-E-132542 (7 March 2012) --- NASA astronaut Don Pettit, Expedition 30 flight engineer, performs a VO2max experiment while using the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station. VO2max uses the Portable Pulmonary Function System (PPFS), CEVIS, Pulmonary Function System (PFS) gas cylinders and mixing bag system, plus multiple other pieces of hardware to measure oxygen uptake and cardiac output.

  10. Williams with VO2max

    NASA Image and Video Library

    2012-08-08

    ISS032-E-016876 (8 Aug. 2012) --- NASA astronaut Sunita Williams, Expedition 32 flight engineer, performs a VO2max experiment while using the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station. VO2max uses the Portable Pulmonary Function System (PPFS), CEVIS, Pulmonary Function System (PFS) gas cylinders and mixing bag system, plus multiple other pieces of hardware to measure oxygen uptake and cardiac output.

  11. Pettit exercises on the CEVIS

    NASA Image and Video Library

    2012-03-07

    ISS030-E-132541 (7 March 2012) --- NASA astronaut Don Pettit, Expedition 30 flight engineer, performs a VO2max experiment while using the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station. VO2max uses the Portable Pulmonary Function System (PPFS), CEVIS, Pulmonary Function System (PFS) gas cylinders and mixing bag system, plus multiple other pieces of hardware to measure oxygen uptake and cardiac output.

  12. Portable precision dc voltage-current transfer standard for electrometer calibration

    USGS Publications Warehouse

    Landis, G.; Godwin, M.

    1982-01-01

    A circuit design is presented for an instrument providing a highly stable and fully adjustable voltage and current in the range of 0-1.999 V or 0-199.9 mV and 10-11-10-15 A. This instrument is used to verify the calibration and performance of dc and vibrating reed electrometers and chart recorders on mass spectrometers of the USGS Isotope Laboratories in Denver.

  13. Portable rapid and quiet drill

    NASA Technical Reports Server (NTRS)

    Badescu, Mireca (Inventor); Chang, Zenshea (Inventor); Sherrit, Stewart (Inventor); Bar-Cohen, Yoseph (Inventor); Bao, Xiaoqi (Inventor)

    2010-01-01

    A hand-held drilling device, and method for drilling using the device, has a housing, a transducer within the housing, with the transducer effectively operating at ultrasonic frequencies, a rotating motor component within the housing and rigid cutting end-effector rotationally connected to the rotating motor component and vibrationally connected to the transducer. The hand-held drilling device of the present invention operates at a noise level of from about 50 decibels or less.

  14. Technical preventive measures in Japan.

    PubMed

    Yonekawa, Y

    1994-05-01

    Technical preventive measures against vibration syndrome in the field of industrial health are reviewed in the present paper. The first technical prevention measure is to reduce vibration transmission from the tools to the operators. This measure employs vibration isolators between the handles and vibration sources of machine tools. Handles of tools using Neidhalt dampers, shear type rubber mounts and springs have reduced frequency-weighted acceleration levels (Lh,w) from 2 dB to 10 dB (Lh,w (dB) = 20 log a/ao; a: frequency-weighted acceleration (rms), ao = 10(-5) m/s2) in Z direction, while no reduction was found in X, Y directions. The second measure is to reduce vibration at the source; New chain saws have been developed to reduce vibration with twin cylinder instead of a single cylinder engines. This cancels unbalanced movements inside the internal combustion engine. Such chain saws reduced Lh,w values more than 10 dB in both front and rear handles except in Z direction of the front handle. A new type of impact wrench has been devised with an oil pulse device to avoid direct metal contact inside the power source. This new impact wrench lowered Lh,w values more than 10 dB in three directions. The third measure is to use a remote control system or to substitute another machine generating less vibration. Vibration reduction at the handle lever of the remote control chain saw was more than 20 dB. A more effective means is to substitute other machines for conventional tools: a hydraulic wheel jumbo instead of a leg-type rock drill; a hydraulic breaker instead of a hand-held breaker. However, these heavy machines produce whole-body vibration which might give rise to other problems such as back pain.

  15. FORTRAN tools

    NASA Technical Reports Server (NTRS)

    Presser, L.

    1978-01-01

    An integrated set of FORTRAN tools that are commercially available is described. The basic purpose of various tools is summarized and their economic impact highlighted. The areas addressed by these tools include: code auditing, error detection, program portability, program instrumentation, documentation, clerical aids, and quality assurance.

  16. DNA-Assisted β-phase Nucleation and Alignment of Molecular Dipoles in PVDF Film: A Realization of Self-Poled Bioinspired Flexible Polymer Nanogenerator for Portable Electronic Devices.

    PubMed

    Tamang, Abiral; Ghosh, Sujoy Kumar; Garain, Samiran; Alam, Md Mehebub; Haeberle, Jörg; Henkel, Karsten; Schmeisser, Dieter; Mandal, Dipankar

    2015-08-05

    A flexible nanogenerator (NG) is fabricated with a poly(vinylidene fluoride) (PVDF) film, where deoxyribonucleic acid (DNA) is the agent for the electroactive β-phase nucleation. Denatured DNA is co-operating to align the molecular -CH2/-CF2 dipoles of PVDF causing piezoelectricity without electrical poling. The NG is capable of harvesting energy from a variety of easily accessible mechanical stress such as human touch, machine vibration, football juggling, and walking. The NG exhibits high piezoelectric energy conversion efficiency facilitating the instant turn-on of several green or blue light-emitting diodes. The generated energy can be used to charge capacitors providing a wide scope for the design of self-powered portable devices.

  17. The Acute Effect of Direct Vibration on Muscular Power Performance in Master Athletes.

    PubMed

    Cochrane, D J

    2016-02-01

    This study examined the acute effect of direct vibration on biceps brachii muscular power in master athletes. 10 healthy male national representative master field-hockey players were randomly assigned to receive 10 min of pulsing sinusoidal vibration or no vibration (control) to the right and left biceps brachii. Pre- and post-testing included lifting 2 repetitions of standing dumbbell (DB) biceps curl at 50% 1 RM (repetition maximum). Mechanical peak power (PP), mean concentric power (MCP) and normalised electromyography (EMG) was assessed during the concentric phase of the biceps curl. Following vibration PP increased 44.3±23.6 W (difference pre-post; p=0.013) compared to control (5.9±9.5 W; p=0.334). Similarly, MCP increased 12.0±4.5 W (p=0.002) compared to control (1.5±0.8 W; p=0.397). However, there was no significant difference in normalised EMG between vibration and control (p>0.05). The increase in PP and MCP did not coincide with an increase in EMG and suggests that other mechanisms may be contributing to changes in muscle performance. Given its ease of use and portability the vibratory device may be considered as an alternative warm-up modality immediately prior to explosive activities. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Advanced active health monitoring system of liquid rocket engines

    NASA Astrophysics Data System (ADS)

    Qing, Xinlin P.; Wu, Zhanjun; Beard, Shawn; Chang, Fu-Kuo

    2008-11-01

    An advanced SMART TAPE system has been developed for real-time in-situ monitoring and long term tracking of structural integrity of pressure vessels in liquid rocket engines. The practical implementation of the structural health monitoring (SHM) system including distributed sensor network, portable diagnostic hardware and dedicated data analysis software is addressed based on the harsh operating environment. Extensive tests were conducted on a simulated large booster LOX-H2 engine propellant duct to evaluate the survivability and functionality of the system under the operating conditions of typical liquid rocket engines such as cryogenic temperature, vibration loads. The test results demonstrated that the developed SHM system could survive the combined cryogenic temperature and vibration environments and effectively detect cracks as small as 2 mm.

  19. Dose-response patterns for vibration-induced white finger

    PubMed Central

    Griffin, M; Bovenzi, M; Nelson, C

    2003-01-01

    Aims: To investigate alternative relations between cumulative exposures to hand-transmitted vibration (taking account of vibration magnitude, lifetime exposure duration, and frequency of vibration) and the development of white finger (Raynaud's phenomenon). Methods: Three previous studies have been combined to provide a group of 1557 users of powered vibratory tools in seven occupational subgroups: stone grinders, stone carvers, quarry drillers, dockyard caulkers, dockyard boilermakers, dockyard painters, and forest workers. The estimated total operating duration in hours was thus obtained for each subject, for each tool, and for all tools combined. From the vibration magnitudes and exposure durations, seven alternative measurements of cumulative exposure were calculated for each subject, using expressions of the form: dose = ∑amiti, where ai is the acceleration magnitude on tool i, ti is the lifetime exposure duration for tool i, and m = 0, 1, 2, or 4. Results: For all seven alternative dose measures, an increase in dose was associated with a significant increase in the occurrence of vibration-induced white finger, after adjustment for age and smoking. However, dose measures with high powers of acceleration (m > 1) faired less well than measures in which the weighted or unweighted acceleration, and lifetime exposure duration, were given equal weight (m = 1). Dose determined solely by the lifetime exposure duration (without consideration of the vibration magnitude) gave better predictions than measures with m greater than unity. All measures of dose calculated from the unweighted acceleration gave better predictions than the equivalent dose measures using acceleration frequency-weighted according to current standards. Conclusions: Since the total duration of exposure does not discriminate between exposures accumulated over the day and those accumulated over years, a linear relation between vibration magnitude and exposure duration seems appropriate for predicting the occurrence of vibration-induced white finger. Poorer predictions were obtained when the currently recommended frequency weighting was employed than when accelerations at all frequencies were given equal weight. Findings suggest that improvements are possible to both the frequency weighting and the time dependency used to predict the development of vibration-induced white finger in current standards. PMID:12499452

  20. Human response to vibration stress in Japanese workers: lessons from our 35-year studies A narrative review

    PubMed Central

    MATOBA, Tsunetaka

    2015-01-01

    The occupational uses with vibratory tools or vehicles provoked health disorders of users. We reviewed narratively our articles of 35 yr studies and their related literatures, and considered the pathophysiology of the hand-arm vibration disorders. Concerning the risk factors of health impairments in workers with vibratory tools, there are two conflicting schools of the researchers: The peripheral school emphasizes that vibration only makes predominant impairments on hands and arms, showing typically Raynaud’s phenomenon in the fingers. In the systemic school, the health disorders are produced by combination with vibration, noise and working environment, namely vibratory work itself, leading to diversified symptoms and signs in relation to systemic impairments. Our 35 yr studies have evidently supported the systemic school, including disorders of the central and autonomic nervous systems. The genesis is vibratory work itself, including vibration, noise, cold working environment, ergonomic and biodynamic conditions, and emotional stress in work. Because the health disorders yield in the whole body, the following measures would contribute to the prevention of health impairments: the attenuation of vibration and noise generated form vibratory machines and the regulations on operating tool hours. In conclusion, this occupational disease results from systemic impairments due to long-term occupational work with vibratory tools. PMID:26460379

  1. Human response to vibration stress in Japanese workers: lessons from our 35-year studies A narrative review.

    PubMed

    Matoba, Tsunetaka

    2015-01-01

    The occupational uses with vibratory tools or vehicles provoked health disorders of users. We reviewed narratively our articles of 35 yr studies and their related literatures, and considered the pathophysiology of the hand-arm vibration disorders. Concerning the risk factors of health impairments in workers with vibratory tools, there are two conflicting schools of the researchers: The peripheral school emphasizes that vibration only makes predominant impairments on hands and arms, showing typically Raynaud's phenomenon in the fingers. In the systemic school, the health disorders are produced by combination with vibration, noise and working environment, namely vibratory work itself, leading to diversified symptoms and signs in relation to systemic impairments. Our 35 yr studies have evidently supported the systemic school, including disorders of the central and autonomic nervous systems. The genesis is vibratory work itself, including vibration, noise, cold working environment, ergonomic and biodynamic conditions, and emotional stress in work. Because the health disorders yield in the whole body, the following measures would contribute to the prevention of health impairments: the attenuation of vibration and noise generated form vibratory machines and the regulations on operating tool hours. In conclusion, this occupational disease results from systemic impairments due to long-term occupational work with vibratory tools.

  2. CHARACTERIZATION OF CHROMIUM-CONTAMINATED SOILS USING FIELD-PORTABLE X-RAY FLUORESCENCE

    EPA Science Inventory

    A detailed characterization of the underlying and adjacent soils near a chrome plating shop utilized field-portable X- ray fluorescence (XRF) as a screening tool. XRF permitted real-time acquisition of estimates for total metal content of soils. A trailer-mounted soil coring unit...

  3. Study of the Vibration Effect on the Cutting Forces and Roughness of Slub Milling

    NASA Astrophysics Data System (ADS)

    Germa, S.; Estrems Amestoy, M.; Sánchez Reinoso, H. T.; Franco Chumillas, P.

    2009-11-01

    For the planning process of slab milling operations, the vibration of the tool is the main factor to be considered. Under vibration conditions, the effect of the small displacements of the cutting tool and the cutting forces on the chip thickness must be minimized in order to avoid undesirable consequences, such as the fast flank wear, superficial defects and roughness increase. In this work, a mathematical model is developed to take into account the combined effect of the cutting tool and workpiece oscillation, as well as the axial errors of different milling tool tips. As a result, the model estimates the variation of the cutting forces and the ideal surface roughness.

  4. Summary of the Ratfor language, an extended portable dialect called REP, its style and flavor, and details of its implementation on the PDP-10

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Figen, J.

    1981-09-10

    Ratfor (RATional FORtran) is a dialect of Fortran that allows structured programming and the use of simple macros. It is the language of the Software Tools package, and is documented in the book Software Tools. It has proved significantly easier than Fortran to read, write, and understand. Although debugging is slightly harder in Ratfor than in Fortran, there is usually less of it to do, since Ratfor lends itself to better program design. Ratfor operates as a preprocessor to any existing Fortran system. It is relatively easy, using Ratfor, to write programs that are portable with little or no changemore » to any environment that supports standard Fortran. REP (Ratfor Extended and Portable) is an extended version of Ratfor. It is fully upward compatible with the Addison-Wesley translator, though there are a few divergences from certain Unix and Software Tools User Group dialects. The principal feature of REP is its fully developed macro facility, a language within a language, capable of doing such things as creating new data types, data structuring, recursive procedures, and much more, portably, and in the spirit of Ratfor, but there are many other lesser though nevertheless important extensions.« less

  5. Examining the Usefulness of ISO 10819 Anti-Vibration Glove Certification.

    PubMed

    Budd, Diandra; House, Ron

    2017-03-01

    Anti-vibration gloves are commonly worn to reduce hand-arm vibration exposure from work with hand-held vibrating tools when higher priority and more effective controls are unavailable. For gloves to be marketed as 'anti-vibration' they must meet the vibration transmissibility criteria described in the International Organization for Standardization (ISO) standard 10819 (2013). Several issues exist with respect to the methodology used for glove testing as well as the requirements for glove design and composition in ISO 10819 (2013). The true usefulness of anti-vibration gloves at preventing hand-arm vibration syndrome (HAVS) is controversial, given that their performance is dependent on tool vibration characteristics and the anthropometrics of workers in real working conditions. The major risk associated with the use of anti-vibration gloves is that it will give employees and employers a false sense of protection against the negative effects of hand-transmitted vibration. This commentary examines the limitations of the current international standards for anti-vibration glove testing and certification, thereby calling into question the degree of protection that anti-vibration gloves provide against HAVS, and cautioning users to consider both their benefits and potential drawbacks on a case-by-case basis. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  6. Vibration manual

    NASA Technical Reports Server (NTRS)

    Green, C.

    1971-01-01

    Guidelines of the methods and applications used in vibration technology at the MSFC are presented. The purpose of the guidelines is to provide a practical tool for coordination and understanding between industry and government groups concerned with vibration of systems and equipments. Topics covered include measuring, reducing, analyzing, and methods for obtaining simulated environments and formulating vibration specifications. Methods for vibration and shock testing, theoretical aspects of data processing, vibration response analysis, and techniques of designing for vibration are also presented.

  7. Tremor and hand-arm vibration syndrome (HAVS) in road maintenance workers.

    PubMed

    Bast-Pettersen, Rita; Ulvestad, Bente; Færden, Karl; Clemm, Thomas Aleksander C; Olsen, Raymond; Ellingsen, Dag Gunnar; Nordby, Karl-Christian

    2017-01-01

    The aim of this study was to evaluate postural and rest tremor among workers using vibrating hand tools, taking into account the possible effects of toxicants such as alcohol and tobacco. A further aim was to study workers diagnosed with hand-arm vibration syndrome (HAVS) at the time of examination. This study comprises 103 road maintenance workers, 55 exposed to vibrating hand tools (age 41.0 years; range 21-62) and 48 referents (age 38.5 years; range 19-64). They were examined with the CATSYS Tremor Pen ® . Exposure to vibrating tools and serum biomarkers of alcohol and tobacco consumption were measured. Cumulative exposure to vibrating tools was associated with increased postural (p < 0.01) and rest tremor (p < 0.05) and with a higher Center Frequency of postural tremor (p < 0.01) among smokers and users of smokeless tobacco. Rest tremor Center Frequency was higher than postural tremor frequency (p < 0.001). The main findings indicate an association between cumulative exposure to hand-held vibrating tools, tremor parameters and consumption of tobacco products. The hand position is important when testing for tremor. Rest tremor had a higher Center Frequency. Postural tremor was more strongly associated with exposure than rest tremor. The finding of increased tremor among the HAVS subjects indicated that tremor might be a part of the clinical picture of a HAVS diagnosis. As with all cross-sectional studies, inferences should be made with caution when drawing conclusions about associations between exposure and possible effects. Future research using longitudinal design is required to validate the findings of the present study.

  8. 29 CFR 1910.243 - Guarding of portable powered tools.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in.... (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater... diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than a...

  9. 29 CFR 1910.243 - Guarding of portable powered tools.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in.... (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater... diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than a...

  10. 29 CFR 1910.243 - Guarding of portable powered tools.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in.... (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater... diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than a...

  11. 29 CFR 1910.243 - Guarding of portable powered tools.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in.... (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater... diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than a...

  12. 29 CFR 1910.243 - Guarding of portable powered tools.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in.... (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater... diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than a...

  13. Vibrotactile pattern recognition: a portable compact tactile matrix.

    PubMed

    Thullier, Francine; Bolmont, Benoît; Lestienne, Francis G

    2012-02-01

    Compact tactile matrix (CTM) is a vibrotactile device composed of a seven-by-seven array of electromechanical vibrators "tactip" used to represent tactile patterns applied to a small skin area. The CTM uses a dynamic feature to generate spatiotemporal tactile patterns. The design requirements focus particularly on maximizing the transmission of the vibration from one tactip to the others as well as to the skin over a square area of 16 cm (2) while simultaneously minimizing the transmission of vibrations throughout the overall structure of the CTM. Experiments were conducted on 22 unpracticed subjects to evaluate how the CTM could be used to develop a tactile semantics for communication of instructions in order to test the ability of the subjects to identify: 1) directional prescriptors for gesture guidance and 2) instructional commands for operational task requirements in a military context. The results indicate that, after familiarization, recognition accuracies in the tactile patterns were remarkably precise for more 80% of the subjects. © 2011 IEEE

  14. A method for analyzing absorbed power distribution in the hand and arm substructures when operating vibrating tools

    NASA Astrophysics Data System (ADS)

    Dong, Jennie H.; Dong, Ren G.; Rakheja, Subhash; Welcome, Daniel E.; McDowell, Thomas W.; Wu, John Z.

    2008-04-01

    In this study it was hypothesized that the vibration-induced injuries or disorders in a substructure of human hand-arm system are primarily associated with the vibration power absorption distributed in that substructure. As the first step to test this hypothesis, the major objective of this study is to develop a method for analyzing the vibration power flow and the distribution of vibration power absorptions in the major substructures (fingers, palm-hand-wrist, forearm and upper arm, and shoulder) of the system exposed to hand-transmitted vibration. A five-degrees-of-freedom model of the system incorporating finger- as well as palm-side driving points was applied for the analysis. The mechanical impedance data measured at the two driving points under four different hand actions involving 50 N grip-only, 15 N grip and 35 N push, 30 N grip and 45 N push, and 50 N grip and 50 N push, were used to identify the model parameters. The vibration power absorption distributed in the substructures were evaluated using vibration spectra measured on many tools. The frequency weightings of the distributed vibration power absorptions were derived and compared with the weighting defined in ISO 5349-1 (2001). This study found that vibration power absorption is primarily distributed in the arm and shoulder when operating low-frequency tools such as rammers, while a high concentration of vibration power absorption in the fingers and hand is observed when operating high-frequency tools, such as grinders. The vibration power absorption distributed in palm-wrist and arm is well correlated with the ISO-weighted acceleration, while the finger vibration power absorption is highly correlated with unweighted acceleration. The finger vibration power absorption-based frequency weighting suggested that exposure to vibration in the frequency range of 16-500 Hz could pose higher risks of developing finger disorders. The results support the use of the frequency weighting specified in the current standard for assessing risks of developing disorders in the palm-wrist-arm substructures. The standardized weighting, however, could overestimate low-frequency effects but greatly underestimate high-frequency effects on the development of finger disorders. The results are further discussed to show that the trends observed in the vibration power absorptions distributed in the substructures are consistent with some major findings of various physiological and epidemiological studies, which provides a support to the hypothesis of this study.

  15. Assessment of hand-transmitted vibration exposure from motorized forks used for beach-cleaning operations.

    PubMed

    McDowell, Thomas W; Welcome, Daniel E; Warren, Christopher; Xu, Xueyan S; Dong, Ren G

    2013-01-01

    Motorized vibrating manure forks were used in beach-cleaning operations following the massive Deepwater Horizon oil spill in the Gulf of Mexico during the summer of 2010. The objectives of this study were to characterize the vibration emissions of these motorized forks and to provide a first approximation of hand-transmitted vibration exposures to workers using these forks for beach cleaning. Eight operators were recruited to operate the motorized forks during this laboratory study. Four fork configurations were used in the study; two motor speeds and two fork basket options were evaluated. Accelerations were measured near each hand as the operators completed the simulated beach-cleaning task. The dominant vibration frequency for these tools was identified to be around 20 Hz. Because acceleration was found to increase with motor speed, workers should consider operating these tools with just enough speed to get the job done. These forks exhibited considerable acceleration magnitudes when unloaded. The study results suggest that the motor should not be operated with the fork in the unloaded state. Anti-vibration gloves are not effective at attenuating the vibration frequencies produced by these forks, and they may even amplify the transmitted vibration and increase hand/arm fatigue. While regular work gloves are suitable, vibration-reducing gloves may not be appropriate for use with these tools. These considerations may also be generally applicable for the use of motorized forks in other workplace environments.

  16. Drawings of the Modular Equipment Transporter and Hand Tool Carrier

    NASA Image and Video Library

    1970-10-12

    S70-50762 (November 1970) --- A line drawing illustrating layout view of the modular equipment transporter (MET) and its equipment. A MET (or Rickshaw, as it has been nicknamed) will be used on the lunar surface for the first time during the Apollo 14 lunar landing mission. The Rickshaw will serve as a portable workbench with a place for the Apollo lunar hand tools (ALHT) and their carrier, three cameras, two sample container bags, a special environment sample container (SESC), a lunar portable magnetometer (LPM) and spare film magazines.

  17. Vibrational spectroscopy

    Treesearch

    Umesh P. Agarwal; Rajai Atalla

    2010-01-01

    Vibrational spectroscopy is an important tool in modern chemistry. In the past two decades, thanks to significant improvements in instrumentation and the development of new interpretive tools, it has become increasingly important for studies of lignin. This chapter presents the three important instrumental methods-Raman spectroscopy, infrared (IR) spectroscopy, and...

  18. Micro-Vibration Performance Prediction of SEPTA24 Using SMeSim (RUAG Space Mechanism Simulator Tool)

    NASA Astrophysics Data System (ADS)

    Omiciuolo, Manolo; Lang, Andreas; Wismer, Stefan; Barth, Stephan; Szekely, Gerhard

    2013-09-01

    Scientific space missions are currently challenging the performances of their payloads. The performances can be dramatically restricted by micro-vibration loads generated by any moving parts of the satellites, thus by Solar Array Drive Assemblies too. Micro-vibration prediction of SADAs is therefore very important to support their design and optimization in the early stages of a programme. The Space Mechanism Simulator (SMeSim) tool, developed by RUAG, enhances the capability of analysing the micro-vibration emissivity of a Solar Array Drive Assembly (SADA) under a specified set of boundary conditions. The tool is developed in the Matlab/Simulink® environment throughout a library of blocks simulating the different components a SADA is made of. The modular architecture of the blocks, assembled by the user, and the set up of the boundary conditions allow time-domain and frequency-domain analyses of a rigid multi-body model with concentrated flexibilities and coupled- electronic control of the mechanism. SMeSim is used to model the SEPTA24 Solar Array Drive Mechanism and predict its micro-vibration emissivity. SMeSim and the return of experience earned throughout its development and use can now support activities like verification by analysis of micro-vibration emissivity requirements and/or design optimization to minimize the micro- vibration emissivity of a SADA.

  19. Study on boring hardened materials dryly by ultrasonic vibration cutter

    NASA Astrophysics Data System (ADS)

    Zhang, Jiangzhong; Zhang, Heng; Zhang, Yue

    2011-05-01

    It has been one of the difficulties that high-precision hole on hardened materials is machined. The supersonic vibration boring acoustic system in the lathe in which supersonic wave energy is applied on tool is introduced to create pulse power on the cutting process. The separation vibration cutting is achieved by the pulse force. The comparative tests on boring accuracy and surface quality are carried. The quality of surface machined by this method is compared to that by grinding. This cutting is the green cutting. The boring process system is stability. Under the condition that the cutting speed is less than or equal to 1/3 the tool vibration speed, the cutting force is pulse force and the Cutting energy is of high concentration in time, space and direction. The pulse energy effects on the cutting unit in less than one ten-thousandth second. Traditional cutting of irregular movement elastic compression are eliminated. The cutting force is greatly reduced. The cutting temperature is at room temperature. The tool life is greatly increased. Shape precision and surface quality is greatly improved. The regulations of the ultrasonic vibration boring dry cutting of hardened material are also summarized. The test results show that the ultrasonic vibration cutting tool boring is of very superior cutting mechanism and is a high-precision deep-hole machining of hardened materials, efficient cutting methods.

  20. Study on the separation effect of high-speed ultrasonic vibration cutting.

    PubMed

    Zhang, Xiangyu; Sui, He; Zhang, Deyuan; Jiang, Xinggang

    2018-07-01

    High-speed ultrasonic vibration cutting (HUVC) has been proven to be significantly effective when turning Ti-6Al-4V alloy in recent researches. Despite of breaking through the cutting speed restriction of the ultrasonic vibration cutting (UVC) method, HUVC can also achieve the reduction of cutting force and the improvements in surface quality and cutting efficiency in the high-speed machining field. These benefits all result from the separation effect that occurs during the HUVC process. Despite the fact that the influences of vibration and cutting parameters have been discussed in previous researches, the separation analysis of HUVC should be conducted in detail in real cutting situations, and the tool geometry parameters should also be considered. In this paper, three situations are investigated in details: (1) cutting without negative transient clearance angle and without tool wear, (2) cutting with negative transient clearance angle and without tool wear, and (3) cutting with tool wear. And then, complete separation state, partial separation state and continuous cutting state are deduced according to real cutting processes. All the analysis about the above situations demonstrate that the tool-workpiece separation will take place only if appropriate cutting parameters, vibration parameters, and tool geometry parameters are set up. The best separation effect was obtained with a low feedrate and a phase shift approaching 180 degrees. Moreover, flank face interference resulted from the negative transient clearance angle and tool wear contributes to an improved separation effect that makes the workpiece and tool separate even at zero phase shift. Finally, axial and radial transient cutting force are firstly obtained to verify the separation effect of HUVC, and the cutting chips are collected to weigh the influence of flank face interference. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. [Occupational exposure to hand-transmitted vibration in Poland].

    PubMed

    Harazin, Barbara; Zieliński, Grzegorz

    2004-01-01

    Occupational exposure to hand transmitted vibration may cause disorders in upper extremities known as hand-arm vibration syndrome. Therefore it is essential to know the sources of vibration, occupational groups exposed to vibration and the number of exposed workers. The aim of the study was to estimate the number of men and women exposed to hand-transmitted vibration in Poland. The completed questionnaires were obtained from 265 (80%) sanitary inspection stations. They included questions on: the name of workplaces, the name and the type of vibration sources, workers' gender, the number of workers exposed to vibration, indicating the extent of exposure measured against the three threshold limit values (< 0.5 TLV; 0.5 < TLV < 1 and > 1 TLV), and the number of workers exposed to hand-transmitted vibration not documented by measurements in a particular workplaces, indicating one of the three possible kinds of exposure (occasional, periodical and constant). The questionnaire data were based on measurements and analyses performed in 1997-2000. The results of the study showed that vibrating tools used by grinders, fitters, locksmiths, rammers, road workers, carpenters and smiths proved to be the most frequent sources of hand-transmitted vibration. It was revealed that 78.6% of operators of these tools were exposed to vibration exceeding 1 TLV. The study also indicated that 17,000 workers, including 1700 women, were exposed to vibration exceeding the threshold limit values.

  2. The Portable Usability Testing Lab: A Flexible Research Tool.

    ERIC Educational Resources Information Center

    Hale, Michael E.; And Others

    A group of faculty at the University of Georgia obtained funding for a research and development facility called the Learning and Performance Support Laboratory (LPSL). One of the LPSL's primary needs was obtaining a portable usability lab for software testing, so the facility obtained the "Luggage Lab 2000." The lab is transportable to…

  3. Portable Technology Comes of Age

    ERIC Educational Resources Information Center

    Wangemann, Paul; Lewis, Nina; Squires, David A.

    2003-01-01

    The PDA was originally conceived of as a portable handheld electronic device that provided a user with a tool to organize his or her life through easy access to a personal calendar, daily planner, and address book. Over the years, these devices have expanded to include many new functions, which have helped more applications in diverse fields. This…

  4. Experimental determination of material damping using vibration analyzer

    NASA Technical Reports Server (NTRS)

    Chowdhury, Mostafiz R.; Chowdhury, Farida

    1990-01-01

    Structural damping is an important dynamic characteristic of engineering materials that helps to damp vibrations by reducing their amplitudes. In this investigation, an experimental method is illustrated to determine the damping characteristics of engineering materials using a dual channel Fast Fourier Transform (FFT) analyzer. A portable Compaq III computer which houses the analyzer, is used to collect the dynamic responses of three metal rods. Time-domain information is analyzed to obtain the logarithmic decrement of their damping. The damping coefficients are then compared to determine the variation of damping from material to material. The variations of damping from one point to another of the same material, due to a fixed point excitation, and the variable damping at a fixed point due to excitation at different points, are also demonstrated.

  5. Soil chemical insights provided through vibrational spectroscopy

    USDA-ARS?s Scientific Manuscript database

    Vibrational spectroscopy techniques provide a powerful approach to study environmental materials and processes. These multifunctional analysis tools can be used to probe molecular vibrations of solid, liquid, and gaseous samples for characterizing materials, elucidating reaction mechanisms, and exam...

  6. Laboratory and Workplace Assessments of Rivet Bucking Bar Vibration Emissions

    PubMed Central

    McDowell, Thomas W.; Warren, Christopher; Xu, Xueyan S.; Welcome, Daniel E.; Dong, Ren G.

    2016-01-01

    Sheet metal workers operating rivet bucking bars are at risk of developing hand and wrist musculoskeletal disorders associated with exposures to hand-transmitted vibrations and forceful exertions required to operate these hand tools. New bucking bar technologies have been introduced in efforts to reduce workplace vibration exposures to these workers. However, the efficacy of these new bucking bar designs has not been well documented. While there are standardized laboratory-based methodologies for assessing the vibration emissions of many types of powered hand tools, no such standard exists for rivet bucking bars. Therefore, this study included the development of a laboratory-based method for assessing bucking bar vibrations which utilizes a simulated riveting task. With this method, this study evaluated three traditional steel bucking bars, three similarly shaped tungsten alloy bars, and three bars featuring spring-dampeners. For comparison the bucking bar vibrations were also assessed during three typical riveting tasks at a large aircraft maintenance facility. The bucking bars were rank-ordered in terms of unweighted and frequency-weighted acceleration measured at the hand-tool interface. The results suggest that the developed laboratory method is a reasonable technique for ranking bucking bar vibration emissions; the lab-based riveting simulations produced similar rankings to the workplace rankings. However, the laboratory-based acceleration averages were considerably lower than the workplace measurements. These observations suggest that the laboratory test results are acceptable for comparing and screening bucking bars, but the laboratory measurements should not be directly used for assessing the risk of workplace bucking bar vibration exposures. The newer bucking bar technologies exhibited significantly reduced vibrations compared to the traditional steel bars. The results of this study, together with other information such as rivet quality, productivity, tool weight, comfort, worker acceptance, and initial cost can be used to make informed bucking bar selections. PMID:25381185

  7. Laboratory and workplace assessments of rivet bucking bar vibration emissions.

    PubMed

    McDowell, Thomas W; Warren, Christopher; Xu, Xueyan S; Welcome, Daniel E; Dong, Ren G

    2015-04-01

    Sheet metal workers operating rivet bucking bars are at risk of developing hand and wrist musculoskeletal disorders associated with exposures to hand-transmitted vibrations and forceful exertions required to operate these hand tools. New bucking bar technologies have been introduced in efforts to reduce workplace vibration exposures to these workers. However, the efficacy of these new bucking bar designs has not been well documented. While there are standardized laboratory-based methodologies for assessing the vibration emissions of many types of powered hand tools, no such standard exists for rivet bucking bars. Therefore, this study included the development of a laboratory-based method for assessing bucking bar vibrations which utilizes a simulated riveting task. With this method, this study evaluated three traditional steel bucking bars, three similarly shaped tungsten alloy bars, and three bars featuring spring-dampeners. For comparison the bucking bar vibrations were also assessed during three typical riveting tasks at a large aircraft maintenance facility. The bucking bars were rank-ordered in terms of unweighted and frequency-weighted acceleration measured at the hand-tool interface. The results suggest that the developed laboratory method is a reasonable technique for ranking bucking bar vibration emissions; the lab-based riveting simulations produced similar rankings to the workplace rankings. However, the laboratory-based acceleration averages were considerably lower than the workplace measurements. These observations suggest that the laboratory test results are acceptable for comparing and screening bucking bars, but the laboratory measurements should not be directly used for assessing the risk of workplace bucking bar vibration exposures. The newer bucking bar technologies exhibited significantly reduced vibrations compared to the traditional steel bars. The results of this study, together with other information such as rivet quality, productivity, tool weight, comfort, worker acceptance, and initial cost can be used to make informed bucking bar selections. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2014.

  8. Acute and chronic neuromuscular adaptations to local vibration training.

    PubMed

    Souron, Robin; Besson, Thibault; Millet, Guillaume Y; Lapole, Thomas

    2017-10-01

    Vibratory stimuli are thought to have the potential to promote neural and/or muscular (re)conditioning. This has been well described for whole-body vibration (WBV), which is commonly used as a training method to improve strength and/or functional abilities. Yet, this technique may present some limitations, especially in clinical settings where patients are unable to maintain an active position during the vibration exposure. Thus, a local vibration (LV) technique, which consists of applying portable vibrators directly over the tendon or muscle belly without active contribution from the participant, may present an alternative to WBV. The purpose of this narrative review is (1) to provide a comprehensive overview of the literature related to the acute and chronic neuromuscular changes associated with LV, and (2) to show that LV training may be an innovative and efficient alternative method to the 'classic' training programs, including in the context of muscle deconditioning prevention or rehabilitation. An acute LV application (one bout of 20-60 min) may be considered as a significant neuromuscular workload, as demonstrated by an impairment of force generating capacity and LV-induced neural changes. Accordingly, it has been reported that a training period of LV is efficient in improving muscular performance over a wide range of training (duration, number of session) and vibration (frequency, amplitude, site of application) parameters. The functional improvements are principally triggered by adaptations within the central nervous system. A model illustrating the current research on LV-induced adaptations is provided.

  9. 29 CFR 1915.34 - Mechanical paint removers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... paints, preservatives, rusts, or other coatings by means of power tools shall be protected against eye...) All portable rotating tools used for the removal of paints, preservatives, rusts or other coatings...

  10. 29 CFR 1915.34 - Mechanical paint removers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... paints, preservatives, rusts, or other coatings by means of power tools shall be protected against eye...) All portable rotating tools used for the removal of paints, preservatives, rusts or other coatings...

  11. 29 CFR 1915.34 - Mechanical paint removers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... paints, preservatives, rusts, or other coatings by means of power tools shall be protected against eye...) All portable rotating tools used for the removal of paints, preservatives, rusts or other coatings...

  12. 29 CFR 1915.34 - Mechanical paint removers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... paints, preservatives, rusts, or other coatings by means of power tools shall be protected against eye...) All portable rotating tools used for the removal of paints, preservatives, rusts or other coatings...

  13. Influence of vibrational treatment on thermomechanical response of material under conditions identical to friction stir welding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Konovalenko, Ivan S., E-mail: ivkon@ispms.tsc.ru; Konovalenko, Igor S., E-mail: igkon@ispms.tsc.ru; Kolubaev, Evgeniy A., E-mail: eak@ispms.tsc.ru

    2015-10-27

    A molecular dynamics model was constructed to describe material loading on the atomic scale by the mode identical to friction stir welding. It was shown that additional vibration applied to the tool during the loading mode provides specified intensity values and continuous thermomechanical action during welding. An increase in additional vibration intensity causes an increase both in the force acting on the workpiece from the rotating tool and in temperature within the welded area.

  14. Hand tool permits shrink sizing of assembled tubing

    NASA Technical Reports Server (NTRS)

    Millett, A.; Odor, M.

    1966-01-01

    Portable tool sizes tubing ends without disassembling the tubing installation. The shrink sizing tool is clamped to the tubing and operated by a ratchet wrench. A gear train forces the tubing end against an appropriate die or mandrel to effect the sizing.

  15. New Applications of Portable Raman Spectroscopy in Agri-Bio-Photonics

    NASA Astrophysics Data System (ADS)

    Voronine, Dmitri; Scully, Rob; Sanders, Virgil

    2014-03-01

    Modern optical techniques based on Raman spectroscopy are being used to monitor and analyze the health of cattle, crops and their natural environment. These optical tools are now available to perform fast, noninvasive analysis of live animals and plants in situ. We will report new applications of a portable handheld Raman spectroscopy to identification and taxonomy of plants. In addition, detection of organic food residues will be demonstrated. Advantages and limitations of current portable instruments will be discussed with suggestions for improved performance by applying enhanced Raman spectroscopic schemes.

  16. Development of enhanced piezoelectric energy harvester induced by human motion.

    PubMed

    Minami, Y; Nakamachi, E

    2012-01-01

    In this study, a high frequency piezoelectric energy harvester converted from the human low vibrated motion energy was newly developed. This hybrid energy harvester consists of the unimorph piezoelectric cantilever and a couple of permanent magnets. One magnet was attached at the end of cantilever, and the counterpart magnet was set at the end of the pendulum. The mechanical energy provided through the human walking motion, which is a typical ubiquitous presence of vibration, is converted to the electric energy via the piezoelectric cantilever vibration system. At first, we studied the energy convert mechanism and the performance of our energy harvester, where the resonance free vibration of unimorph cantilever with one permanent magnet under a rather high frequency was induced by the artificial low frequency vibration. The counterpart magnet attached on the pendulum. Next, we equipped the counterpart permanent magnet pendulum, which was fluctuated under a very low frequency by the human walking, and the piezoelectric cantilever, which had the permanent magnet at the end. The low-to-high frequency convert "hybrid system" can be characterized as an enhanced energy harvest one. We examined and obtained maximum values of voltage and power in this system, as 1.2V and 1.2 µW. Those results show the possibility to apply for the energy harvester in the portable and implantable Bio-MEMS devices.

  17. Portable kit for the assessment of gait parameters in daily telerehabilitation.

    PubMed

    Giansanti, Daniele; Morelli, Sandra; Maccioni, Giovanni; Grigioni, Mauro

    2013-03-01

    When designing a complete process of daily telerehabilitation, it should be borne in mind that patients should be furnished with properly designed methodologies for executing specific motion tasks and the assessment of the relevant parameters. In general, such a process should comprehend three basic elements in both the hospital and the home: (a) instrumented walkways, (b) walking aids or supports, and (c) equipment for the assessment of parameters. The objective, with gait being the focus, of this study was thus to design a simple, portable kit-as an alternative to the complex and expensive instruments currently used-to be easily interfaced or integrated with the instrumented walkways and aids/supports both for self-monitoring while patients are exercising with their own aids and for clinical reporting. The proposed system is a portable kit that furnishes useful parameters with feedback to both the patient and the trainer/therapist. Capable of being integrated with the most common mechanical tools used in motion rehabilitation (handrail, scales, walkways, etc.), it constantly monitors and quantitatively assesses progress in rehabilitation care. It is composed of one step counter, photo-emitter detectors, one central unit for collecting and processing the telemetrically transmitted data, and a software interface. The system has been successfully validated on 16 subjects at the second level of the Tinetti test in a clinical application for both home and the hospital. The portable kit can be used with different rehabilitation tools and on varying ground rugosity. Advantages include (a) very low cost, when compared with optoelectronic solutions or other portable devices, (b) very high accuracy, also for subjects with imbalance problems, compared with other commercial solutions, and (c) integration (compatibility) with any rehabilitative tool.

  18. Application of design for six sigma methodology on portable water filter that uses membrane filtration system: A preliminary study

    NASA Astrophysics Data System (ADS)

    Fahrul Hassan, Mohd; Jusoh, Suhada; Zaini Yunos, Muhamad; Arifin, A. M. T.; Ismail, A. E.; Rasidi Ibrahim, M.; Zulafif Rahim, M.

    2017-09-01

    Portable water filter has grown significantly in recent years. The use of water bottles as a water drink stuff using hand pump water filtration unit has been suggested to replace water bottled during outdoor recreational activities and for emergency supplies. However, quality of water still the issue related to contaminated water due to the residual waste plants, bacteria, and so on. Based on these issues, the study was carried out to design a portable water filter that uses membrane filtration system by applying Design for Six Sigma. Design for Six Sigma methodology consists of five stages which is Define, Measure, Analyze, Design and Verify. There were several tools have been used in each stage in order to come out with a specific objective. In the Define stage, questionnaire approach was used to identify the needs of portable water filter in the future from potential users. Next, Quality Function Deployment (QFD) tool was used in the Measure stage to measure the users’ needs into engineering characteristics. Based on the information in the Measure stage, morphological chart and weighted decision matrix tools were used in the Analyze stage. This stage performed several activities including concept generation and selection. Once the selection of the final concept completed, detail drawing was made in the Design stage. Then, prototype was developed in the Verify stage to conduct proof-of-concept testing. The results that obtained from each stage have been reported in this paper. From this study, it can be concluded that the application of Design for Six Sigma in designing a future portable water filter that uses membrane filtration system is a good start in looking for a new alternative concept with a completed supporting document.

  19. A portable helium sniffer

    USGS Publications Warehouse

    Friedman, Irving; Denton, E.H.

    1976-01-01

    A portable helium sniffer has been developed for field use. The instrument is mounted in a four-wheel-drive pickup truck and can detect 50 parts per billion of helium in soil gas. The usefulness of helium sniffing in soil is being investigated as a prospecting tool in gas, oil, uranium, and geothermal prospecting as well as in earthquake prediction.

  20. Using Personal Portable Devices as Learning Tools in the English Class

    ERIC Educational Resources Information Center

    Herrera Díaz, Luz Edith; Cruz Ramos, María de los Milagros; Sandoval Sánchez, Mario Alberto

    2014-01-01

    A group of university students used a variety of personal portable devices (cellphones, tablets, laptops, and netbooks) which distracted them in English class. This qualitative action research aimed to implement activities entailing the use of such devices and to learn their impact on students' learning and the use of English in class. Thus, a…

  1. Analysis of real-time vibration data

    USGS Publications Warehouse

    Safak, E.

    2005-01-01

    In recent years, a few structures have been instrumented to provide continuous vibration data in real time, recording not only large-amplitude motions generated by extreme loads, but also small-amplitude motions generated by ambient loads. The main objective in continuous recording is to track any changes in structural characteristics, and to detect damage after an extreme event, such as an earthquake or explosion. The Fourier-based spectral analysis methods have been the primary tool to analyze vibration data from structures. In general, such methods do not work well for real-time data, because real-time data are mainly composed of ambient vibrations with very low amplitudes and signal-to-noise ratios. The long duration, linearity, and the stationarity of ambient data, however, allow us to utilize statistical signal processing tools, which can compensate for the adverse effects of low amplitudes and high noise. The analysis of real-time data requires tools and techniques that can be applied in real-time; i.e., data are processed and analyzed while being acquired. This paper presents some of the basic tools and techniques for processing and analyzing real-time vibration data. The topics discussed include utilization of running time windows, tracking mean and mean-square values, filtering, system identification, and damage detection.

  2. Determining the vibrations between sensor and sample in SQUID microscopy

    NASA Astrophysics Data System (ADS)

    Schiessl, Daniel; Kirtley, John R.; Paulius, Lisa; Rosenberg, Aaron J.; Palmstrom, Johanna C.; Ullah, Rahim R.; Holland, Connor M.; Fung, Y.-K.-K.; Ketchen, Mark B.; Gibson, Gerald W.; Moler, Kathryn A.

    2016-12-01

    Vibrations can cause noise in scanning probe microscopies. Relative vibrations between the scanning sensor and the sample are important but can be more difficult to determine than absolute vibrations or vibrations relative to the laboratory. We measure the noise spectral density in a scanning SQUID microscope as a function of position near a localized source of magnetic field and show that we can determine the spectra of all three components of the relative sensor-sample vibrations. This method is a powerful tool for diagnosing vibrational noise in scanning microscopies.

  3. Enhanced data consistency of a portable gait measurement system.

    PubMed

    Lin, Hsien-I; Chiang, Y P

    2013-11-01

    A gait measurement system is a useful tool for rehabilitation applications. Such a system is used to conduct gait experiments in large workplaces such as laboratories where gait measurement equipment can be permanently installed. However, a gait measurement system should be portable if it is to be used in clinics or community centers for aged people. In a portable gait measurement system, the workspace is limited and landmarks on a subject may not be visible to the cameras during experiments. Thus, we propose a virtual-marker function to obtain positions of unseen landmarks for maintaining data consistency. This work develops a portable clinical gait measurement system consisting of lightweight motion capture devices, force plates, and a walkway assembled from plywood boards. We evaluated the portable clinic gait system with 11 normal subjects in three consecutive days in a limited experimental space. Results of gait analysis based on the verification of within-day and between-day coefficients of multiple correlations show that the proposed portable gait system is reliable.

  4. Enhanced data consistency of a portable gait measurement system

    NASA Astrophysics Data System (ADS)

    Lin, Hsien-I.; Chiang, Y. P.

    2013-11-01

    A gait measurement system is a useful tool for rehabilitation applications. Such a system is used to conduct gait experiments in large workplaces such as laboratories where gait measurement equipment can be permanently installed. However, a gait measurement system should be portable if it is to be used in clinics or community centers for aged people. In a portable gait measurement system, the workspace is limited and landmarks on a subject may not be visible to the cameras during experiments. Thus, we propose a virtual-marker function to obtain positions of unseen landmarks for maintaining data consistency. This work develops a portable clinical gait measurement system consisting of lightweight motion capture devices, force plates, and a walkway assembled from plywood boards. We evaluated the portable clinic gait system with 11 normal subjects in three consecutive days in a limited experimental space. Results of gait analysis based on the verification of within-day and between-day coefficients of multiple correlations show that the proposed portable gait system is reliable.

  5. Substrate-borne vibrational signals in intraspecific communication of GWSS

    USDA-ARS?s Scientific Manuscript database

    Exploitation of vibrational signals for suppressing glassy-winged sharpshooter (GWSS) populations in citrus orchards and vineyards could prove to be a useful tool. However, existing knowledge of GWSS vibrational communication is insufficient to implement a management program for this pest in Califor...

  6. Teaching Web Security Using Portable Virtual Labs

    ERIC Educational Resources Information Center

    Chen, Li-Chiou; Tao, Lixin

    2012-01-01

    We have developed a tool called Secure WEb dEvelopment Teaching (SWEET) to introduce security concepts and practices for web application development. This tool provides introductory tutorials, teaching modules utilizing virtualized hands-on exercises, and project ideas in web application security. In addition, the tool provides pre-configured…

  7. Cluster: Carpentry. Course: Carpentry. Research Project.

    ERIC Educational Resources Information Center

    Sanford - Lee County Schools, NC.

    The course on carpentry is divided into 14 sequential units, with several task packages within each, covering the following topics: carpentry hand tools; portable power tools; working machine tools; lumber; fasteners and adhesives; plans, specifications, and codes for houses; footings and foundations for a house; household cabinets; floor framing…

  8. Biodynamic response at the palm of the human hand subjected to a random vibration.

    PubMed

    Dong, Ren G; McDowell, Thomas W; Welcome, Daniel E

    2005-01-01

    This study investigated the biodynamic response (BR) distributed at the palm of the hand subjected to a random vibration. Twelve male subjects were used in the experiment. Each subject applied three coupling actions (grip-only, push-only, and combined grip and push) on a simulated tool handle at three different levels (50, 75, and 100 N) of palm force. This study found that the hand-arm system resonated mostly in the frequency range of 20 to 50 Hz, depending on the specific test treatment and individual characteristics. The maximum vibration power transmission through the palm occurred at the resonant frequency. Increasing the effective palm force generally increased the BR magnitude and resonant frequency. The apparent stiffness measured at the middle frequencies (80-100 Hz) is correlated to the BR in almost the entire frequency range (20-1,000 Hz). Under the same palm force, the push-only action corresponded to the highest BR values while the grip-only action generally produced the lowest values. Since the resonant frequency range matches the dominant vibration frequency range of many percussive tools, it is anticipated that the palm BR and vibration power transmission may have an association with vibration-induced injuries or disorders in the wrist-arm system among the workers using these tools.

  9. Calibration-free portable Young's-modulus tester with isolated langasite oscillator.

    PubMed

    Ogi, Hirotsugu; Sakamoto, Yuto; Hirao, Masahiko

    2014-09-01

    A ballpoint-pen-type portable ultrasonic oscillator is developed for quantitative measurement of Young's modulus on a solid. It consists of an electrodeless rod-shaped langasite oscillator with a tungsten-carbide spherical-shaped tip at the end, permanent magnets for making a constant force at the contact interface, and antennas for exciting and detecting the longitudinal vibration contactlessly. The resonance frequency of the oscillator is changed by contact with the specimen, reflecting Young's modulus of the specimen at the contact area. The langasite oscillator is supported at the nodal points so that its acoustical contact occurs only at the specimen, making a calibration-free measurement realistic. Young's moduli of various specimens were evaluated within 15% error just by touching the specimens with the probe. The error becomes smaller than 10% for lower Young-modulus materials (<∼150 GPa). Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Acceptance test report for portable exhauster POR-007/Skid E

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kriskovich, J.R.

    1998-07-24

    This document describes Acceptance Testing performed on Portable Exhauster POR-007/Skid E. It includes measurements of bearing vibration levels, pressure decay testing, programmable logic controller interlocks, high vacuum, flow and pressure control functional testing. The purpose of Acceptance testing documented by this report was to demonstrate compliance of the exhausters with the performance criteria established within HNF-0490, Rev. 1 following a repair and upgrade effort at Hanford. In addition, data obtained during this testing is required for the resolution of outstanding Non-conformance Reports (NCR), and finally, to demonstrate the functionality of the associated software for the pressure control and high vacuummore » exhauster operating modes provided for by W-320. Additional testing not required by the ATP was also performed to assist in the disposition and close out of receiving inspection report and for application design information (system curve). Results of this testing are also captured within this document.« less

  11. A Portable, Shock-Proof, Surface-Heated Droplet PCR System for Escherichia coli Detection

    PubMed Central

    Angus, Scott V.; Cho, Soohee; Harshman, Dustin K.; Song, Jae-Young; Yoon, Jeong-Yeol

    2015-01-01

    A novel polymerase chain reaction (PCR) device was developed that uses wire-guided droplet manipulation (WDM) to guide a droplet over three different heating chambers. After PCR amplification, end-point detection is achieved using a smartphone-based fluorescence microscope. The device was tested for identification of the 16S rRNA gene V3 hypervariable region from Escherichia coli genomic DNA. The lower limit of detection was 103 genome copies per sample. The device is portable with smartphone-based end-point detection and provides the assay results quickly (15 min for a 30-cycle amplification) and accurately. The system is also shock and vibration resistant, due to the multiple points of contact between the droplet and the thermocouple and the Teflon film on the heater surfaces. The thermocouple also provides realtime droplet temperature feedback to ensure it reaches the set temperature before moving to the next chamber/step in PCR. The device is equipped to use either silicone oil or coconut oil. Coconut oil provides additional portability and ease of transportation by eliminating spilling because its high melting temperature means it is solid at room temperature. PMID:26164008

  12. [A study on the thermographic diagnosis of vibration disease of tie-tamper operators in the Japanese National Railways].

    PubMed

    Hirahata, H

    1984-01-01

    There have been many studies of thermographic diagnosis of vibration disease, but few of them seem to have discussed tie-tamping machines as a cause. This study focuses on thermographic diagnosis of vibration disease in tie-tamper operators of the Japanese National Railways. In the diagnosis the subject's both hands were immersed in water at 10 degrees C for 3 minutes before being examined. Variables such as season, age, type of vibration tool used and total operating time were considered. These were selected as outside variables and thermographic results as dependent variables, in Quantification Method II. Season and confirmation of vibration disease were found to have a relationship to thermographic scaling, but no such relationship was found for age, type of vibration tool used, or total operating time. A cross-analysis of variables confirmed the relationship with season, and revealed that there were fewer confirmed cases of vibration disease in spring and summer than in fall and winter. It was finally concluded that thermographic analysis is more reliable in colder weather.

  13. Substrate-borne vibrational signals in intraspecific communication of glassy-winged sharpshooters (GWSS)

    USDA-ARS?s Scientific Manuscript database

    Exploitation of vibrational signals for suppressing glassy-winged sharpshooter (GWSS) populations could prove to be a useful tool. However, existing knowledge on GWSS vibrational communication is insufficient to implement a management program for this pest in California. Therefore, the objective of ...

  14. Wireless alerting system using vibration for vehicles dashboard

    NASA Astrophysics Data System (ADS)

    Raj, Sweta; Rai, Shweta; Magaramagara, Wilbert; Sivacoumar, R.

    2017-11-01

    This paper aims at improving the engine life of any vehicle through a continuous measurement and monitoring of vital engine operational parameters and providing an effective alerting to drivers for any abnormality. Vehicles currently are using audio and visible alerting signals through alarms and light as a warning to the driver but these are not effective in noisy environments and during daylight. Through the use of the sense of feeling a driver can be alerted effectively. The need to no other vehicle parameter needs to be aided through the mobile display (phone).Thus a system is designed and implements to measure engine temperature, RPM, Oil level and Coolant level using appropriate sensors and a wireless communication (Bluetooth) is established to actuate a portable vibration control device and to read the different vehicle sensor readings through an android application for display and diagnosis.

  15. A portable station for recording fire weather data

    Treesearch

    John R. Murray; Clive M. Countryman

    1968-01-01

    A portable station for recording fire weather data has been developed for use in wildland fires, prescribed burns, evaluating sites for fire weather stations, and fire research. Housed in a mechanic's tool box, the station weighs about 60 pounds. One man can have it ready to operate in about 15 minutes. The unit can record five weather variables, but additional...

  16. Optical and Image Transmission through Desert Atmospheres

    DTIC Science & Technology

    1994-01-25

    control tha camer and to record and analyze th digitized imag. 23 Recording of the target video scenes was initially severely limited by wind -induced...vibrations of the digital camera platform. In order to overcome this limitation, a portable wind resistant cage, measuring approximately 3x3x5 m2, was...monitoring and recording equipment was also housed inside the wind cage. In order to minimize its weight, the wind cage was constructed with 2"x4a wooden frame

  17. General Construction Trades. Volume 1. Teacher's Guide.

    ERIC Educational Resources Information Center

    East Texas State Univ., Commerce. Occupational Curriculum Lab.

    Ten units on the world of construction and twelve units on carpentry are presented in this teacher's guide. The construction units include the following: safety; human relations in the shop; grooming and hygiene; hand tools; measurement; portable power tools, stationary power tools; fastening devices; and job application and interview. The…

  18. A Vibrating Wire System For Quadrupole Fiducialization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wolf, Zachary

    2010-12-13

    A vibrating wire system is being developed to fiducialize the quadrupoles between undulator segments in the LCLS. This note provides a detailed analysis of the system. The LCLS will have quadrupoles between the undulator segments to keep the electron beam focused. If the quadrupoles are not centered on the beam axis, the beam will receive transverse kicks, causing it to deviate from the undulator axis. Beam based alignment will be used to move the quadrupoles onto a straight line, but an initial, conventional alignment must place the quadrupole centers on a straight line to 100 {micro}m. In the fiducialization stepmore » of the initial alignment, the position of the center of the quadrupole is measured relative to tooling balls on the outside of the quadrupole. The alignment crews then use the tooling balls to place the magnet in the tunnel. The required error on the location of the quadrupole center relative to the tooling balls must be less than 25 {micro}m. In this note, we analyze a system under construction for the quadrupole fiducialization. The system uses the vibrating wire technique to position a wire onto the quadrupole magnetic axis. The wire position is then related to tooling balls using wire position detectors. The tooling balls on the wire position detectors are finally related to tooling balls on the quadrupole to perform the fiducialization. The total 25 {micro}m fiducialization error must be divided between these three steps. The wire must be positioned onto the quadrupole magnetic axis to within 10 {micro}m, the wire position must be measured relative to tooling balls on the wire position detectors to within 15 {micro}m, and tooling balls on the wire position detectors must be related to tooling balls on the quadrupole to within 10 {micro}m. The techniques used in these three steps will be discussed. The note begins by discussing various quadrupole fiducialization techniques used in the past and discusses why the vibrating wire technique is our method of choice. We then give an overview of the measurement system showing how the vibrating wire is positioned onto the quadrupole axis, how the wire position detectors locate the wire relative to tooling balls without touching the wire, and how the tooling ball positions are all measured. The novel feature of this system is the vibrating wire which we discuss in depth. We analyze the wire dynamics and calculate the expected sensitivity of the system. The note should be an aid in debugging the system by providing calculations to compare measurements to.« less

  19. Scavenging energy from the motion of human lower limbs via a piezoelectric energy harvester

    NASA Astrophysics Data System (ADS)

    Fan, Kangqi; Yu, Bo; Zhu, Yingmin; Liu, Zhaohui; Wang, Liansong

    2017-03-01

    Scavenging energy from human motion through piezoelectric transduction has been considered as a feasible alternative to batteries for powering portable devices and realizing self-sustained devices. To date, most piezoelectric energy harvesters (PEHs) developed can only collect energy from the uni-directional mechanical vibration. This deficiency severely limits their applicability to human motion energy harvesting because the human motion involves diverse mechanical motions. In this paper, a novel PEH is proposed to harvest energy from the motion of human lower limbs. This PEH is composed of two piezoelectric cantilever beams, a sleeve and a ferromagnetic ball. The two beams are designed to sense the vibration along the tibial axis and conduct piezoelectric conversion. The ball senses the leg swing and actuates the two beams to vibrate via magnetic coupling. Theoretical and experimental studies indicate that the proposed PEH can scavenge energy from both the vibration and the swing. During each stride, the PEH can produce multiple peaks in voltage output, which is attributed to the superposition of different excitations. Moreover, the root-mean-square (RMS) voltage output of the PEH increases when the walking speed ranges from 2 to 8 km/h. In addition, the ultra-low frequencies of human motion are also up-converted by the proposed design.

  20. Portable parallel portfolio optimization in the Aurora Financial Management System

    NASA Astrophysics Data System (ADS)

    Laure, Erwin; Moritsch, Hans

    2001-07-01

    Financial planning problems are formulated as large scale, stochastic, multiperiod, tree structured optimization problems. An efficient technique for solving this kind of problems is the nested Benders decomposition method. In this paper we present a parallel, portable, asynchronous implementation of this technique. To achieve our portability goals we elected the programming language Java for our implementation and used a high level Java based framework, called OpusJava, for expressing the parallelism potential as well as synchronization constraints. Our implementation is embedded within a modular decision support tool for portfolio and asset liability management, the Aurora Financial Management System.

  1. A study of the mechanical vibrations of a table-top extreme ultraviolet interference nanolithography tool.

    PubMed

    Prezioso, S; De Marco, P; Zuppella, P; Santucci, S; Ottaviano, L

    2010-04-01

    A prototype low cost table-top extreme ultraviolet (EUV) laser source (1.5 ns pulse duration, lambda=46.9 nm) was successfully employed as a laboratory scale interference nanolithography (INL) tool. Interference patterns were obtained with a simple Lloyd's mirror setup. Periodic structures on Polymethylmethacrylate/Si substrates were produced on large areas (8 mm(2)) with resolutions from 400 to 22.5 nm half pitch (the smallest resolution achieved so far with table-top EUV laser sources). The mechanical vibrations affecting both the laser source and Lloyd's setup were studied to determine if and how they affect the lateral resolution of the lithographic system. The vibration dynamics was described by a statistical model based on the assumption that the instantaneous position of the vibrating mechanical parts follows a normal distribution. An algorithm was developed to simulate the process of sample irradiation under different vibrations. The comparison between simulations and experiments allowed to estimate the characteristic amplitude of vibrations that was deduced to be lower than 50 nm. The same algorithm was used to reproduce the expected pattern profiles in the lambda/4 half pitch physical resolution limit. In that limit, a nonzero pattern modulation amplitude was obtained from the simulations, comparable to the peak-to-valley height (2-3 nm) measured for the 45 nm spaced fringes, indicating that the mechanical vibrations affecting the INL tool do not represent a limit in scaling down the resolution.

  2. Vibrations Detection in Industrial Pumps Based on Spectral Analysis to Increase Their Efficiency

    NASA Astrophysics Data System (ADS)

    Rachid, Belhadef; Hafaifa, Ahmed; Boumehraz, Mohamed

    2016-03-01

    Spectral analysis is the key tool for the study of vibration signals in rotating machinery. In this work, the vibration analysis applied for conditional preventive maintenance of such machines is proposed, as part of resolved problems related to vibration detection on the organs of these machines. The vibration signal of a centrifugal pump was treated to mount the benefits of the approach proposed. The obtained results present the signal estimation of a pump vibration using Fourier transform technique compared by the spectral analysis methods based on Prony approach.

  3. A novel technique for micro-hole forming on skull with the assistance of ultrasonic vibration.

    PubMed

    Li, Zhe; Yang, Daoguo; Hao, Weidong; Wu, Tiecheng; Wu, Song; Li, Xiaoping

    2016-04-01

    Micro-hole opening on skull is technically challenging and is hard to realize by micro-drilling. Low-stiffness of the drill bit is a serious drawback in micro-drilling. To deal with this problem, a novel ultrasonic vibration assisted micro-hole forming technique has been developed. Tip geometry and vibration amplitude are two key factors affecting the performance of this hole forming technique. To investigate their effects, experiment was carried out with 300μm diameter tools of three different tip geometries at three different vibration amplitudes. Hole forming performance was evaluated by the required thrust force, dimensional accuracy, exit burr and micro-structure of bone tissue around the generated hole. Based on the findings from current study, the 60° conically tipped tool helps generate a micro-hole of better quality at a smaller thrust force, and it is more suitable for hole forming than the 120° conically tipped tool and the blunt tipped tool. As for the vibration amplitude, when a larger amplitude is used, a micro-hole of better quality and higher dimensional accuracy can be formed at a smaller thrust force. Findings from this study would lay a technical foundation for accurately generating a high-quality micro-hole on skull, which enables minimally invasive insertion of a microelectrode into brain for neural activity measuring. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. [Measurement and analysis of hand-transmitted vibration of vibration tools in workplace for automobile casting and assembly].

    PubMed

    Xie, X S; Qi, C; Du, X Y; Shi, W W; Zhang, M

    2016-02-20

    To investigate the features of hand-transmitted vibration of common vibration tools in the workplace for automobile casting and assembly. From September to October, 2014, measurement and spectral analysis were performed for 16 typical hand tools(including percussion drill, pneumatic wrench, grinding machine, internal grinder, and arc welding machine) in 6 workplaces for automobile casting and assembly according to ISO 5349-1-2001 Mechanical vibration-Measurement and evaluation of human exposure to hand-transmitted vibration-part 1: General requirements and ISO 5349-2-2001 Mechanical vibration-Measurement and evaluation of human exposure to hand-transmitted vibration-Part 2: Practical guidance for measurement in the workplace. The vibration acceleration waveforms of shearing machine, arc welding machine, and pneumatic wrench were mainly impact wave and random wave, while those of internal grinder, angle grinder, percussion drill, and grinding machine were mainly long-and short-period waves. The daily exposure duration to vibration of electric wrench, pneumatic wrench, shearing machine, percussion drill, and internal grinder was about 150 minutes, while that of plasma cutting machine, angle grinder, grinding machine, bench grinder, and arc welding machine was about 400 minutes. The range of vibration total value(ahv) was as follows: pneumatic wrench 0.30~11.04 m/s(2), grinding wheel 1.61~8.97 m/s(2), internal grinder 1.46~8.70 m/s(2), percussion drill 11.10~14.50 m/s(2), and arc welding machine 0.21~2.18 m/s(2). The workers engaged in cleaning had the longest daily exposure duration to vibration, and the effective value of 8-hour energy-equivalent frequency-weighted acceleration for them[A(8)] was 8.03 m/s(2), while this value for workers engaged in assembly was 4.78 m/s(2). The frequency spectrogram with an 1/3-time frequency interval showed that grinding machine, angle grinder, and percussion drill had a high vibration acceleration, and the vibration limit curve was recommended for those with a frequency higher than 400 min/d. The workers who are engaged in cleaning, grinding, and a few positions of assembly and use grinding machine, angle grinder, internal grinder, and percussion drill are exposed to vibrations with a high vibration acceleration and at a high position of the frequency spectrum. The hand-transmitted vibration in the positions of cutting, polishing, and cleaning in automobile casting has great harm, and the harm caused by pneumatic wrench in automobile assembly should be taken seriously.

  5. Portable monitoring for the diagnosis of obstructive sleep apnea.

    PubMed

    Collop, Nancy A

    2008-11-01

    The demand for expedient diagnosis of suspected obstructive sleep apnea (OSA) has increased due to improved awareness of sleep disorders. Polysomnography (PSG) is the current preferred diagnostic modality but is relatively inconvenient, expensive and inefficient. Portable monitoring has been developed and is widely used in countries outside the United States as an alternative approach. A portable monitor records fewer physiologic variables but is typically unattended and can be performed in the home. Numerous portable monitor studies have been performed over the past two to three decades. The US government and medical societies have extensively reviewed this literature several times in an attempt to determine if portable monitoring should be more broadly used for diagnosing OSA. In March 2008, the US Centers for Medicare and Medicaid Services released a statement allowing the use of portable monitoring to diagnose OSA and prescribe continuous positive airway pressure. This has potentially opened the door for more widespread use of these devices. This review will focus on the literature that has examined portable monitoring as a diagnostic tool for OSA. It is anticipated that portable monitoring as a diagnostic modality for OSA will be used more frequently in the United States following the Centers for Medicare and Medicaid Services ruling. Physicians and others considering the use of portable monitors should thoroughly understand the advantages and limitations of this technology.

  6. Dose-response relation between exposure to two types of hand-arm vibration and sensorineural perception of vibration.

    PubMed

    Virokannas, H

    1995-05-01

    31 railway workers and 32 lumberjacks were examined to compare the dose-response relation between the exposure to two types of hand-arm vibration and the sensory disturbances in peripheral nerves as evaluated by the vibration perception thresholds (VPTs). Clinical examinations were carried out that included measurements of the VPTs, and electroneuromyography (ENMG), and an inquiry to confirm the use of vibrating tools. Diseases of the central nervous system and neuropathies were checked by inquiry and a clinical examination, diabetes was excluded by a blood sample analysis, and the subjects with carpal tunnel syndrome confirmed with ENMG were excluded from the study. Lifetime use of hand held tamping machines (railway workers) and chain saws (lumberjacks) had a significant correlation with the VPTs at frequencies from 32 to 500 Hz. The increase of the VPTs (250 Hz) in relation to use of vibrating tools was 1.8-fold higher on average in the whole group and 2.3-fold higher in the young (< 45) railway workers who had used hand held tamping machines, than in the corresponding groups of lumberjacks, who had used chain saws, whereas the frequency weighted acceleration of vibration in tamping machines was fourfold. There was a significant dose-response relation between the exposure to hand-arm vibration and the VPTs. The VPTs as a function of the frequency weighted acceleration of vibration and the exposure to vibration gave promising results for assessment of the risk of damage to sensory nerves induced by vibration.

  7. Study on residual stresses in ultrasonic torsional vibration assisted micro-milling

    NASA Astrophysics Data System (ADS)

    Lu, Zesheng; Hu, Haijun; Sun, Yazhou; Sun, Qing

    2010-10-01

    It is well known that machining induced residual stresses can seriously affect the dimensional accuracy, corrosion and wear resistance, etc., and further influence the longevity and reliability of Micro-Optical Components (MOC). In Ultrasonic Torsional Vibration Assisted Micro-milling (UTVAM), cutting parameters, vibration parameters, mill cutter parameters, the status of wear length of tool flank are the main factors which affect residual stresses. A 2D model of UTVAM was established with FE analysis software ABAQUS. Johnson-Cook's flow stress model and shear failure principle are used as the workpiece material model and failure principle, while friction between tool and workpiece uses modified Coulomb's law whose sliding friction area is combined with sticking friction. By means of FEA, the influence rules of cutting parameters, vibration parameters, mill cutter parameters, the status of wear length of tool flank on residual stresses are obtained, which provides a basis for choosing optimal process parameters and improving the longevity and reliability of MOC.

  8. Evaluation of the XSENS Force Shoe on ISS

    NASA Technical Reports Server (NTRS)

    Hanson, A. M.; Peters, B. T.; Newby, N.; Ploutz-Snyder, L

    2014-01-01

    The Advanced Resistive Exercise Device (ARED) offers crewmembers a wide range of resistance exercises but does not provide any type of load monitoring; any load data received are based on crew self-report of dialed in load. This lack of real-time ARED load monitoring severely limits research analysis. To address this issue, portable load monitoring technologies are being evaluated to act as a surrogate to ARED's failed instrumentation. The XSENS ForceShoe"TM" is a commercial portable load monitoring tool, and performed well in ground tests. The ForceShoe "TM" was recently deployed on the International Space Station (ISS), and is being evaluated as a tool to monitor ARED loads.

  9. Development and implementation of a portable grating interferometer system as a standard tool for testing optics at the Advanced Photon Source beamline 1-BM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Assoufid, Lahsen; Shi, Xianbo; Marathe, Shashidhara

    We developed a portable X-ray grating interferometer setup as a standard tool for testing optics at the Advanced Photon Source (APS) beamline 1-BM. The interferometer can be operated in phase-stepping, Moiré, or single-grating harmonic imaging mode with 1-D or 2-D gratings. All of the interferometer motions are motorized; hence, it is much easier and quicker to switch between the different modes of operation. A novel aspect of this new instrument is its designed portability. While the setup is designed to be primarily used as a standard tool for testing optics at 1-BM, it could be potentially deployed at other APSmore » beamlines for beam coherence and wavefront characterization or imaging. The design of the interferometer system is described in detail and coherence measurements obtained at the APS 34-ID-E beamline are presented. The coherence was probed in two directions using a 2-D checkerboard, a linear, and a circular grating at X-ray energies of 8 keV, 11 keV, and 18 keV.« less

  10. A systematic review of portable electronic technology for health education in resource-limited settings.

    PubMed

    McHenry, Megan S; Fischer, Lydia J; Chun, Yeona; Vreeman, Rachel C

    2017-08-01

    The objective of this study is to conduct a systematic review of the literature of how portable electronic technologies with offline functionality are perceived and used to provide health education in resource-limited settings. Three reviewers evaluated articles and performed a bibliography search to identify studies describing health education delivered by portable electronic device with offline functionality in low- or middle-income countries. Data extracted included: study population; study design and type of analysis; type of technology used; method of use; setting of technology use; impact on caregivers, patients, or overall health outcomes; and reported limitations. Searches yielded 5514 unique titles. Out of 75 critically reviewed full-text articles, 10 met inclusion criteria. Study locations included Botswana, Peru, Kenya, Thailand, Nigeria, India, Ghana, and Tanzania. Topics addressed included: development of healthcare worker training modules, clinical decision support tools, patient education tools, perceptions and usability of portable electronic technology, and comparisons of technologies and/or mobile applications. Studies primarily looked at the assessment of developed educational modules on trainee health knowledge, perceptions and usability of technology, and comparisons of technologies. Overall, studies reported positive results for portable electronic device-based health education, frequently reporting increased provider/patient knowledge, improved patient outcomes in both quality of care and management, increased provider comfort level with technology, and an environment characterized by increased levels of technology-based, informal learning situations. Negative assessments included high investment costs, lack of technical support, and fear of device theft. While the research is limited, portable electronic educational resources present promising avenues to increase access to effective health education in resource-limited settings, contingent on the development of culturally adapted and functional materials to be used on such devices.

  11. [The hand-arm vibration syndrome: (II). The diagnostic aspects and fitness criteria].

    PubMed

    Bovenzi, M

    1999-01-01

    Part II of this paper reviews the clinical and laboratory methods to diagnose the neurological, vascular and osteoarticular components of the hand-arm vibration syndrome. The prognosis and reversibility of vibration-induced neurological and vascular disorders after cessation of vibration exposure or the introduction of powered tools equipped with vibration isolation systems are discussed on the basis of the results of follow-up clinical investigations and longitudinal epidemiologic studies. Finally, the review debates some of the methodological aspects connected with the health surveillance of vibration-exposed workers and considers the possible medical contra-indications for prolonged exposure to hand-transmitted vibration.

  12. The effects of vibration-reducing gloves on finger vibration

    PubMed Central

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.

    2015-01-01

    Vibration-reducing (VR) gloves have been used to reduce the hand-transmitted vibration exposures from machines and powered hand tools but their effectiveness remains unclear, especially for finger protection. The objectives of this study are to determine whether VR gloves can attenuate the vibration transmitted to the fingers and to enhance the understanding of the mechanisms of how these gloves work. Seven adult male subjects participated in the experiment. The fixed factors evaluated include hand force (four levels), glove condition (gel-filled, air bladder, no gloves), and location of the finger vibration measurement. A 3-D laser vibrometer was used to measure the vibrations on the fingers with and without wearing a glove on a 3-D hand-arm vibration test system. This study finds that the effect of VR gloves on the finger vibration depends on not only the gloves but also their influence on the distribution of the finger contact stiffness and the grip effort. As a result, the gloves increase the vibration in the fingertip area but marginally reduce the vibration in the proximal area at some frequencies below 100 Hz. On average, the gloves reduce the vibration of the entire fingers by less than 3% at frequencies below 80 Hz but increase at frequencies from 80 to 400 Hz. At higher frequencies, the gel-filled glove is more effective at reducing the finger vibration than the air bladder-filled glove. The implications of these findings are discussed. Relevance to industry Prolonged, intensive exposure to hand-transmitted vibration can cause hand-arm vibration syndrome. Vibration-reducing gloves have been used as an alternative approach to reduce the vibration exposure. However, their effectiveness for reducing finger-transmitted vibrations remains unclear. This study enhanced the understanding of the glove effects on finger vibration and provided useful information on the effectiveness of typical VR gloves at reducing the vibration transmitted to the fingers. The new results and knowledge can be used to help select appropriate gloves for the operations of powered hand tools, to help perform risk assessment of the vibration exposure, and to help design better VR gloves. PMID:26543297

  13. Tool Condition Monitoring in Micro-End Milling using wavelets

    NASA Astrophysics Data System (ADS)

    Dubey, N. K.; Roushan, A.; Rao, U. S.; Sandeep, K.; Patra, K.

    2018-04-01

    In this work, Tool Condition Monitoring (TCM) strategy is developed for micro-end milling of titanium alloy and mild steel work-pieces. Full immersion slot milling experiments are conducted using a solid tungsten carbide end mill for more than 1900 s to have reasonable amount of tool wear. During the micro-end milling process, cutting force and vibration signals are acquired using Kistler piezo-electric 3-component force dynamometer (9256C2) and accelerometer (NI cDAQ-9188) respectively. The force components and the vibration signals are processed using Discrete Wavelet Transformation (DWT) in both time and frequency window. 5-level wavelet packet decomposition using Db-8 wavelet is carried out and the detailed coefficients D1 to D5 for each of the signals are obtained. The results of the wavelet transformation are correlated with the tool wear. In case of vibration signals, de-noising is done for higher frequency components (D1) and force signals were de-noised for lower frequency components (D5). Increasing value of MAD (Mean Absolute Deviation) of the detail coefficients for successive channels depicted tool wear. The predictions of the tool wear are confirmed from the actual wear observed in the SEM of the worn tool.

  14. Development of Universal Portable Spray Stand for Touch-Up Process in The Automotive Paintshop

    NASA Astrophysics Data System (ADS)

    Fatah Muhamed Mukhtar, Muhamed Abdul; Mohideen Shahul Hameed, Rasool

    2016-02-01

    A spray stand is a custom-made tool used to hold the automotive body parts as well as the devices used to facilitate the operator during the Touch Up process in Paint shop production. This paper discusses about the development of Universal Portable Spray Stand (UPSS) as a tool to hold various types of automotive body parts and model of car during the painting process. The main objective of this study is to determine the effective application of UPSS at the International College of Automotive (ICAM) and also in the automotive industry. This will be helpful to add features to the current spray stand in ICAM and to add value to the spray stand based on selected criteria which are universal, portable and cost saving. In addition, study in the UPSS is also expected to bring reduction in cycle time during the touch up process, in the paint defects and in the ergonomics issues among the operators.

  15. Effect of shelf aging on vibration transmissibility of anti-vibration gloves

    PubMed Central

    SHIBATA, Nobuyuki

    2017-01-01

    Anti-vibration gloves have been used in real workplaces to reduce vibration transmitted through hand-held power tools to the hand. Generally materials used for vibration attenuation in gloves are resilient materials composed of certain synthetic and/or composite polymers. The mechanical characteristics of the resilient materials used in anti-vibration gloves are prone to be influenced by environmental conditions such as temperature, humidity, and photo-irradiation, which cause material degradation and aging. This study focused on the influence of shelf aging on the vibration attenuation performance of air-packaged anti-vibration gloves following 2 yr of shelf aging. Effects of shelf aging on the vibration attenuation performance of anti-vibration gloves were examined according to the Japan industrial standard JIS T8114 test protocol. The findings indicate that shelf aging induces the reduction of vibration attenuation performance in air-packaged anti-vibration gloves. PMID:28978817

  16. Flexible structure control experiments using a real-time workstation for computer-aided control engineering

    NASA Technical Reports Server (NTRS)

    Stieber, Michael E.

    1989-01-01

    A Real-Time Workstation for Computer-Aided Control Engineering has been developed jointly by the Communications Research Centre (CRC) and Ruhr-Universitaet Bochum (RUB), West Germany. The system is presently used for the development and experimental verification of control techniques for large space systems with significant structural flexibility. The Real-Time Workstation essentially is an implementation of RUB's extensive Computer-Aided Control Engineering package KEDDC on an INTEL micro-computer running under the RMS real-time operating system. The portable system supports system identification, analysis, control design and simulation, as well as the immediate implementation and test of control systems. The Real-Time Workstation is currently being used by CRC to study control/structure interaction on a ground-based structure called DAISY, whose design was inspired by a reflector antenna. DAISY emulates the dynamics of a large flexible spacecraft with the following characteristics: rigid body modes, many clustered vibration modes with low frequencies and extremely low damping. The Real-Time Workstation was found to be a very powerful tool for experimental studies, supporting control design and simulation, and conducting and evaluating tests withn one integrated environment.

  17. Removing function model and experiments on ultrasonic polishing molding die

    NASA Astrophysics Data System (ADS)

    Huang, Qitai; Ni, Ying; Yu, Jingchi

    2010-10-01

    Low temperature glass molding technology is the main method on volume-producing high precision middle and small diameter optical cells in the future. While the accuracy of the molding die will effect the cell precision, so the high precision molding die development is one of the most important part of the low temperature glass molding technology. The molding die is manufactured from high rigid and crisp metal alloy, with the ultrasonic vibration character of high vibration frequency and concentrative energy distribution; abrasive particles will impact the rigid metal alloy surface with very high speed that will remove the material from the work piece. Ultrasonic can make the rigid metal alloy molding die controllable polishing and reduce the roughness and surface error. Different from other ultrasonic fabrication method, untouched ultrasonic polishing is applied on polish the molding die, that means the tool does not touch the work piece in the process of polishing. The abrasive particles vibrate around the balance position with high speed and frequency under the drive of ultrasonic vibration in the liquid medium and impact the workspace surface, the energy of abrasive particles come from ultrasonic vibration, while not from the direct hammer blow of the tool. So a nummular vibrator simple harmonic vibrates on an infinity plane surface is considered as a model of ultrasonic polishing working condition. According to Huygens theory the sound field distribution on a plane surface is analyzed and calculated, the tool removing function is also deduced from this distribution. Then the simple point ultrasonic polishing experiment is proceeded to certificate the theory validity.

  18. Piezoelectric Motors and Transformers

    NASA Astrophysics Data System (ADS)

    Uchino, K.

    Piezoelectric ceramics forms a new field between electronic and structural ceramics [1-4]. Application fields are classified into three categories: positioners, motors, and vibration suppressors. From the market research result for 80 Japanese component industries in 1992, tiny motors in the range of 5-8 mm are required in large numbers for office and portable equipment; the conventional electromagnetic (EM) motors are rather difficult to produce in this size with sufficient energy efficiency, while Silicon MEMS actuators are too small to be used in practice. Piezoelectric ultrasonic motors whose efficiency is insensitive to size are superior in the millimeter motor area. The manufacturing precision of optical instruments such as lasers and cameras, and the positioning accuracy for fabricating semiconductor chips are of the order of 0.1μm which is much smaller than the backlash of the EM motors. Vibration suppression in space structures and military vehicles also require compact but mighty piezoelectric actuators.

  19. Dose-response relation between exposure to two types of hand-arm vibration and sensorineural perception of vibration.

    PubMed Central

    Virokannas, H

    1995-01-01

    OBJECTIVES--31 railway workers and 32 lumberjacks were examined to compare the dose-response relation between the exposure to two types of hand-arm vibration and the sensory disturbances in peripheral nerves as evaluated by the vibration perception thresholds (VPTs). METHODS--Clinical examinations were carried out that included measurements of the VPTs, and electroneuromyography (ENMG), and an inquiry to confirm the use of vibrating tools. Diseases of the central nervous system and neuropathies were checked by inquiry and a clinical examination, diabetes was excluded by a blood sample analysis, and the subjects with carpal tunnel syndrome confirmed with ENMG were excluded from the study. RESULTS--Lifetime use of hand held tamping machines (railway workers) and chain saws (lumberjacks) had a significant correlation with the VPTs at frequencies from 32 to 500 Hz. The increase of the VPTs (250 Hz) in relation to use of vibrating tools was 1.8-fold higher on average in the whole group and 2.3-fold higher in the young (< 45) railway workers who had used hand held tamping machines, than in the corresponding groups of lumberjacks, who had used chain saws, whereas the frequency weighted acceleration of vibration in tamping machines was fourfold. CONCLUSION--There was a significant dose-response relation between the exposure to hand-arm vibration and the VPTs. The VPTs as a function of the frequency weighted acceleration of vibration and the exposure to vibration gave promising results for assessment of the risk of damage to sensory nerves induced by vibration. PMID:7795756

  20. Calculation of Coupled Vibroacoustics Response Estimates from a Library of Available Uncoupled Transfer Function Sets

    NASA Technical Reports Server (NTRS)

    Smith, Andrew; LaVerde, Bruce; Hunt, Ron; Fulcher, Clay; Towner, Robert; McDonald, Emmett

    2012-01-01

    The design and theoretical basis of a new database tool that quickly generates vibroacoustic response estimates using a library of transfer functions (TFs) is discussed. During the early stages of a launch vehicle development program, these response estimates can be used to provide vibration environment specification to hardware vendors. The tool accesses TFs from a database, combines the TFs, and multiplies these by input excitations to estimate vibration responses. The database is populated with two sets of uncoupled TFs; the first set representing vibration response of a bare panel, designated as H(sup s), and the second set representing the response of the free-free component equipment by itself, designated as H(sup c). For a particular configuration undergoing analysis, the appropriate H(sup s) and H(sup c) are selected and coupled to generate an integrated TF, designated as H(sup s +c). This integrated TF is then used with the appropriate input excitations to estimate vibration responses. This simple yet powerful tool enables a user to estimate vibration responses without directly using finite element models, so long as suitable H(sup s) and H(sup c) sets are defined in the database libraries. The paper discusses the preparation of the database tool and provides the assumptions and methodologies necessary to combine H(sup s) and H(sup c) sets into an integrated H(sup s + c). An experimental validation of the approach is also presented.

  1. Portable image-manipulation software: what is the extra development cost?

    PubMed

    Ligier, Y; Ratib, O; Funk, M; Perrier, R; Girard, C; Logean, M

    1992-08-01

    A hospital-wide picture archiving and communication system (PACS) project is currently under development at the University Hospital of Geneva. The visualization and manipulation of images provided by different imaging modalities constitutes one of the most challenging component of a PACS. It was necessary to provide this visualization software on a number of types of workstations because of the varying requirements imposed by the range of clinical uses it must serve. The user interface must be the same, independent of the underlying workstation. In addition to a standard set of image-manipulation and processing tools, there is a need for more specific clinical tools that can be easily adapted to specific medical requirements. To achieve this goal, it was elected to develop a modular and portable software called OSIRIS. This software is available on two different operating systems (the UNIX standard X-11/OSF-Motif based workstations and the Macintosh family) and can be easily ported to other systems. The extra effort required to design such software in a modular and portable way was worthwhile because it resulted in a platform that can be easily expanded and adapted to a variety of specific clinical applications. Its portability allows users to benefit from the rapidly evolving workstation technology and to adapt the performance to suit their needs.

  2. A prospective cohort study of exposure-response relationship for vibration-induced white finger.

    PubMed

    Bovenzi, M

    2010-01-01

    To investigate prospectively the relation between vibration-induced white finger (VWF) and measures of cumulative (lifetime) exposure to hand-transmitted vibration (HTV). Two hundred and forty-nine HTV workers and 138 control men of the same companies participated in a 3-year follow-up study. The diagnosis of VWF (Raynaud's phenomenon in the controls) was based on the medical history, the administration of colour charts and the results of a cold test. Tool vibration magnitudes were expressed as root-mean-square (r.m.s.) acceleration, frequency-weighted according to international standard ISO 5349-1 and also unweighted over the frequency range 6.3-1250 Hz. From the vibration magnitudes and exposure durations, alternative measures of cumulative vibration dose were calculated for each HTV worker, according to the expression: dose = Sigmaa(i)(m)t(i), where a(i) is the acceleration magnitude on tool i, t(i) is the lifetime exposure duration (hours) for tool i, and m = 0, 1, 2 or 4. The incidence of VWF varied from 5 to 6% in the HTV workers versus 0 to 1.5% for Raynaud's phenomenon in the controls. After adjusting for potential confounders, measures of cumulative vibration dose derived from total operating hours and high powers of unweighted acceleration (ie, , with m>1) gave better predictions of the occurrence of VWF than dose measures calculated from frequency-weighted acceleration (ie, ). These findings were observed in the entire sample of HTV workers, in those with no VWF at the initial investigation, and in those with normal cold test results at baseline. This prospective cohort study suggests that measures of cumulative vibration doses constructed from unweighted r.m.s. acceleration perform better for the prediction of VWF than dose measures calculated according to the recommendations of current standards. These findings should contribute to the improvement of the ISO frequency weighting for evaluating the severity of hand-transmitted vibration.

  3. Vibrations transmitted from human hands to upper arm, shoulder, back, neck, and head.

    PubMed

    Xu, Xueyan S; Dong, Ren G; Welcome, Daniel E; Warren, Christopher; McDowell, Thomas W; Wu, John Z

    2017-12-01

    Some powered hand tools can generate significant vibration at frequencies below 25 Hz. It is not clear whether such vibration can be effectively transmitted to the upper arm, shoulder, neck, and head and cause adverse effects in these substructures. The objective of this study is to investigate the vibration transmission from the human hands to these substructures. Eight human subjects participated in the experiment, which was conducted on a 1-D vibration test system. Unlike many vibration transmission studies, both the right and left hand-arm systems were simultaneously exposed to the vibration to simulate a working posture in the experiment. A laser vibrometer and three accelerometers were used to measure the vibration transmitted to the substructures. The apparent mass at the palm of each hand was also measured to help in understanding the transmitted vibration and biodynamic response. This study found that the upper arm resonance frequency was 7-12 Hz, the shoulder resonance was 7-9 Hz, and the back and neck resonances were 6-7 Hz. The responses were affected by the hand-arm posture, applied hand force, and vibration magnitude. The transmissibility measured on the upper arm had a trend similar to that of the apparent mass measured at the palm in their major resonant frequency ranges. The implications of the results are discussed. Musculoskeletal disorders (MSDs) of the shoulder and neck are important issues among many workers. Many of these workers use heavy-duty powered hand tools. The combined mechanical loads and vibration exposures are among the major factors contributing to the development of MSDs. The vibration characteristics of the body segments examined in this study can be used to help understand MSDs and to help develop more effective intervention methods.

  4. Vibrations transmitted from human hands to upper arm, shoulder, back, neck, and head

    PubMed Central

    Xu, Xueyan S.; Dong, Ren G.; Welcome, Daniel E.; Warren, Christopher; McDowell, Thomas W.; Wu, John Z.

    2016-01-01

    Some powered hand tools can generate significant vibration at frequencies below 25 Hz. It is not clear whether such vibration can be effectively transmitted to the upper arm, shoulder, neck, and head and cause adverse effects in these substructures. The objective of this study is to investigate the vibration transmission from the human hands to these substructures. Eight human subjects participated in the experiment, which was conducted on a 1-D vibration test system. Unlike many vibration transmission studies, both the right and left hand-arm systems were simultaneously exposed to the vibration to simulate a working posture in the experiment. A laser vibrometer and three accelerometers were used to measure the vibration transmitted to the substructures. The apparent mass at the palm of each hand was also measured to help in understanding the transmitted vibration and biodynamic response. This study found that the upper arm resonance frequency was 7–12 Hz, the shoulder resonance was 7–9 Hz, and the back and neck resonances were 6–7 Hz. The responses were affected by the hand-arm posture, applied hand force, and vibration magnitude. The transmissibility measured on the upper arm had a trend similar to that of the apparent mass measured at the palm in their major resonant frequency ranges. The implications of the results are discussed. Relevance to industry Musculoskeletal disorders (MSDs) of the shoulder and neck are important issues among many workers. Many of these workers use heavy-duty powered hand tools. The combined mechanical loads and vibration exposures are among the major factors contributing to the development of MSDs. The vibration characteristics of the body segments examined in this study can be used to help understand MSDs and to help develop more effective intervention methods. PMID:29123326

  5. Torsional vibration signal analysis as a diagnostic tool for planetary gear fault detection

    NASA Astrophysics Data System (ADS)

    Xue, Song; Howard, Ian

    2018-02-01

    This paper aims to investigate the effectiveness of using the torsional vibration signal as a diagnostic tool for planetary gearbox faults detection. The traditional approach for condition monitoring of the planetary gear uses a stationary transducer mounted on the ring gear casing to measure all the vibration data when the planet gears pass by with the rotation of the carrier arm. However, the time variant vibration transfer paths between the stationary transducer and the rotating planet gear modulate the resultant vibration spectra and make it complex. Torsional vibration signals are theoretically free from this modulation effect and therefore, it is expected to be much easier and more effective to diagnose planetary gear faults using the fault diagnostic information extracted from the torsional vibration. In this paper, a 20 degree of freedom planetary gear lumped-parameter model was developed to obtain the gear dynamic response. In the model, the gear mesh stiffness variations are the main internal vibration generation mechanism and the finite element models were developed for calculation of the sun-planet and ring-planet gear mesh stiffnesses. Gear faults on different components were created in the finite element models to calculate the resultant gear mesh stiffnesses, which were incorporated into the planetary gear model later on to obtain the faulted vibration signal. Some advanced signal processing techniques were utilized to analyses the fault diagnostic results from the torsional vibration. It was found that the planetary gear torsional vibration not only successfully detected the gear fault, but also had the potential to indicate the location of the gear fault. As a result, the planetary gear torsional vibration can be considered an effective alternative approach for planetary gear condition monitoring.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, S; Young, C; Mizaikoff, B

    Fundamental vibrational and rotational modes associated with most inorganic and organic molecules are spectroscopically accessible within the mid-infrared (MIR; 3-20 {micro}m) regime of the electromagnetic spectrum. The interaction between MIR photons and organic molecules provides particularly sharp transitions, which - despite the wide variety of organic molecules - provide unique MIR absorption spectra reflecting the molecularly characteristic arrangement of chemical bonds within the probed molecules via the frequency position of the associated vibrational and rotational transitions. Given the inherent molecular selectivity and achievable sensitivity, MIR spectroscopy provides an ideal platform for optical sensing applications. Despite this potential, early MIR sensingmore » applications were limited to localized applications due to the size of the involved instrumentation, and limited availability of appropriately compact MIR optical components including light sources, detectors, waveguides, and spectrometers. During the last decades, engineering advances in photonics and optical engineering have facilitated the translation of benchtop-style MIR spectroscopy into miniaturized optical sensing schemes providing a footprint compatible with portable instrumentation requirements for field deployable analytical tools. In this trend article, we will discuss recent advances and future strategies for miniaturizing MIR sensor technology. The Beer-Lambert law implies that achievable limit of detection (LOD) for any optical sensor system improves by increasing the interaction length between photons and target analyte species such as e.g., folding the optical path multiple times as in multi-pass gas phase sensing; however, this governing paradigm naturally leads to an increase in system dimensions. Hence, miniaturization of optical sensing system requires scaling down of each optical component, yet improving the performance of each optical element within a smaller form factor for overall at least maintaining, or ideally improving the achievable sensitivity.« less

  7. The relationships between residual stress relaxation and texture development in AZ31 Mg alloys via the vibratory stress relief technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Jia-Siang, E-mail: andy304312003@yahoo.com.tw; Hsieh, Chih-Chun, E-mail: jeromehsieh@gmail.com; Lai, Hsuan-Han, E-mail: g099066020@mail.nchu.edu.tw

    2015-01-15

    A systematic study of residual stress relaxation and the texture evolution of cold-rolled AZ31 Mg alloys using the vibratory stress relief technique with a simple cantilever beam vibration system was performed using a high-resolution X-ray diffractometer and a portable X-ray residual stress analyzer. The effects of vibrational stress excitation on the surface residual stress distribution and on the texture of pole figures (0002) occurring during the vibratory stress relief were examined. Compared with the effects corresponding to the same alloy under non-vibration condition, it can be observed that the uniform surface residual stress distribution and relaxation of the compressive residualmore » stress in the stress concentration zone were observed rather than all of the residual stresses being eliminated. Furthermore, with an increase in the vibrational aging time, the compressive residual stress, texture density, and (0002) preferred orientation increased first and then decreased. It should be underlined that the vibratory stress relief process for the vibrational aging time of more than 10 min is able to weaken the strong basal textures of AZ31 Mg alloys, which is valuable for enhancement of their formability and is responsible for an almost perfect 3D-Debye–Scherrer ring. - Highlights: • 3D-Debye ring about VSR technique is not discussed in the existing literature. • A newly developed VSR method is suitable for small or thin workpieces. • The cosα method accurately and effectively determines the residual stresses. • The VSR technique is valuable for enhancement of their formability. • The texture and preferred orientation change with the vibrational aging time.« less

  8. Vibration and impulsivity analysis of hand held olive beaters.

    PubMed

    Deboli, Roberto; Calvo, Angela; Preti, Christian

    2016-07-01

    To provide more effective evaluations of hand arm vibration syndromes caused by hand held olive beaters, this study focused on two aspects: the acceleration measured at the tool pole and the analysis of the impulsivity, using the crest factor. The signals were frequency weighted using the weighting curve Wh as described in the ISO 5349-1 standard. The same source signals were also filtered by the Wh-bl filter (ISO/TS 15694), because the weighting filter Wh (unlike the Wh-bl filter) could underestimate the effect of high frequency vibration on vibration-induced finger disorders. Ten (experienced) male operators used three beater models (battery powered) in the real olive harvesting condition. High vibration total values were obtained with values never lower than 20 m(-2). Concerning the crest factor, the values ranged from 5 to more than 22. This work demonstrated that the hand held olive beaters produced high impulsive loads comparable to the industry hand held tools. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  9. Microminiature linear split Stirling cryogenic cooler for portable infrared imagers

    NASA Astrophysics Data System (ADS)

    Veprik, A.; Vilenchik, H.; Riabzev, S.; Pundak, N.

    2007-04-01

    Novel tactics employed in carrying out military and antiterrorist operations call for the development of a new generation of warfare, among which sophisticated portable infrared (IR) imagers for surveillance, reconnaissance, targeting and navigation play an important role. The superior performance of such imagers relies on novel optronic technologies and maintaining the infrared focal plane arrays at cryogenic temperatures using closed cycle refrigerators. Traditionally, rotary driven Stirling cryogenic engines are used for this purpose. As compared to their military off-theshelf linear rivals, they are lighter, more compact and normally consume less electrical power. Latest technological advances in industrial development of high-temperature (100K) infrared detectors initialized R&D activity towards developing microminiature cryogenic coolers, both of rotary and linear types. On this occasion, split linearly driven cryogenic coolers appear to be more suitable for the above applications. Their known advantages include flexibility in the system design, inherently longer life time, low vibration export and superior aural stealth. Moreover, recent progress in designing highly efficient "moving magnet" resonant linear drives and driving electronics enable further essential reduction of the cooler size, weight and power consumption. The authors report on the development and project status of a novel Ricor model K527 microminiature split Stirling linear cryogenic cooler designed especially for the portable infrared imagers.

  10. A vacuum microgripping tool with integrated vibration releasing capability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rong, Weibin; Fan, Zenghua, E-mail: zenghua-fan@163.com; Wang, Lefeng

    2014-08-01

    Pick-and-place of micro-objects is a basic task in various micromanipulation demands. Reliable releasing of micro-objects is usually disturbed due to strong scale effects. This paper focuses on a vacuum micro-gripper with vibration releasing functionality, which was designed and assembled for reliable micromanipulation tasks. Accordingly, a vibration releasing strategy of implementing a piezoelectric actuator on the vacuum microgripping tool is presented to address the releasing problem. The releasing mechanism was illustrated using a dynamic micro contact model. This model was developed via theoretical analysis, simulations and pull-off force measurement using atomic force microscopy. Micromanipulation experiments were conducted to verify the performancemore » of the vacuum micro-gripper. The results show that, with the assistance of the vibration releasing, the vacuum microgripping tool can achieve reliable release of micro-objects. A releasing location accuracy of 4.5±0.5 μm and a successful releasing rate of around 100% (which is based on 110 trials) were achieved for manipulating polystyrene microspheres with radius of 35–100 μm.« less

  11. Dynamic analysis and vibration testing of CFRP drive-line system used in heavy-duty machine tool

    NASA Astrophysics Data System (ADS)

    Yang, Mo; Gui, Lin; Hu, Yefa; Ding, Guoping; Song, Chunsheng

    2018-03-01

    Low critical rotary speed and large vibration in the metal drive-line system of heavy-duty machine tool affect the machining precision seriously. Replacing metal drive-line with the CFRP drive-line can effectively solve this problem. Based on the composite laminated theory and the transfer matrix method (TMM), this paper puts forward a modified TMM to analyze dynamic characteristics of CFRP drive-line system. With this modified TMM, the CFRP drive-line of a heavy vertical miller is analyzed. And the finite element modal analysis model of the shafting is established. The results of the modified TMM and finite element analysis (FEA) show that the modified TMM can effectively predict the critical rotary speed of CFRP drive-line. And the critical rotary speed of CFRP drive-line is 20% higher than that of the original metal drive-line. Then, the vibration of the CFRP and the metal drive-line were tested. The test results show that application of the CFRP drive shaft in the drive-line can effectively reduce the vibration of the heavy-duty machine tool.

  12. Higher-order vibrational mode frequency tuning utilizing fishbone-shaped microelectromechanical systems resonator

    NASA Astrophysics Data System (ADS)

    Suzuki, Naoya; Tanigawa, Hiroshi; Suzuki, Kenichiro

    2013-04-01

    Resonators based on microelectromechanical systems (MEMS) have received considerable attention for their applications for wireless equipment. The requirements for this application include small size, high frequency, wide bandwidth and high portability. However, few MEMS resonators with wide-frequency tuning have been reported. A fishbone-shaped resonator has a resonant frequency with a maximum response that can be changed according to the location and number of several exciting electrodes. Therefore, it can be expected to provide wide-frequency tuning. The resonator has three types of electrostatic forces that can be generated to deform a main beam. We evaluate the vibrational modes caused by each exciting electrodes by comparing simulated results with measured ones. We then successfully demonstrate the frequency tuning of the first to fifth resonant modes by using the algorithm we propose here. The resulting frequency tuning covers 178 to 1746 kHz. In addition, we investigate the suppression of the anchor loss to enhance the Q-factor. An experiment shows that tapered-shaped anchors provide a higher Q-factor than rectangular-shaped anchors. The Q-factor of the resonators supported by suspension beams is also discussed. Because the suspension beams cause complicated vibrational modes for higher frequencies, the enhancement of the Q-factor for high vibrational modes cannot be obtained here. At present, the tapered-anchor resonators are thought to be most suitable for frequency tuning applications.

  13. Portable spark-gap arc generator

    NASA Technical Reports Server (NTRS)

    Ignaczak, L. R.

    1978-01-01

    Self-contained spark generator that simulates electrical noise caused by discharge of static charge is useful tool when checking sensitive component and equipment. In test set-up, device introduces repeatable noise pulses as behavior of components is monitored. Generator uses only standard commercial parts and weighs only 4 pounds; portable dc power supply is used. Two configurations of generator have been developed: one is free-running arc source, and one delivers spark in response to triggering pulse.

  14. PubMedPortable: A Framework for Supporting the Development of Text Mining Applications.

    PubMed

    Döring, Kersten; Grüning, Björn A; Telukunta, Kiran K; Thomas, Philippe; Günther, Stefan

    2016-01-01

    Information extraction from biomedical literature is continuously growing in scope and importance. Many tools exist that perform named entity recognition, e.g. of proteins, chemical compounds, and diseases. Furthermore, several approaches deal with the extraction of relations between identified entities. The BioCreative community supports these developments with yearly open challenges, which led to a standardised XML text annotation format called BioC. PubMed provides access to the largest open biomedical literature repository, but there is no unified way of connecting its data to natural language processing tools. Therefore, an appropriate data environment is needed as a basis to combine different software solutions and to develop customised text mining applications. PubMedPortable builds a relational database and a full text index on PubMed citations. It can be applied either to the complete PubMed data set or an arbitrary subset of downloaded PubMed XML files. The software provides the infrastructure to combine stand-alone applications by exporting different data formats, e.g. BioC. The presented workflows show how to use PubMedPortable to retrieve, store, and analyse a disease-specific data set. The provided use cases are well documented in the PubMedPortable wiki. The open-source software library is small, easy to use, and scalable to the user's system requirements. It is freely available for Linux on the web at https://github.com/KerstenDoering/PubMedPortable and for other operating systems as a virtual container. The approach was tested extensively and applied successfully in several projects.

  15. PubMedPortable: A Framework for Supporting the Development of Text Mining Applications

    PubMed Central

    Döring, Kersten; Grüning, Björn A.; Telukunta, Kiran K.; Thomas, Philippe; Günther, Stefan

    2016-01-01

    Information extraction from biomedical literature is continuously growing in scope and importance. Many tools exist that perform named entity recognition, e.g. of proteins, chemical compounds, and diseases. Furthermore, several approaches deal with the extraction of relations between identified entities. The BioCreative community supports these developments with yearly open challenges, which led to a standardised XML text annotation format called BioC. PubMed provides access to the largest open biomedical literature repository, but there is no unified way of connecting its data to natural language processing tools. Therefore, an appropriate data environment is needed as a basis to combine different software solutions and to develop customised text mining applications. PubMedPortable builds a relational database and a full text index on PubMed citations. It can be applied either to the complete PubMed data set or an arbitrary subset of downloaded PubMed XML files. The software provides the infrastructure to combine stand-alone applications by exporting different data formats, e.g. BioC. The presented workflows show how to use PubMedPortable to retrieve, store, and analyse a disease-specific data set. The provided use cases are well documented in the PubMedPortable wiki. The open-source software library is small, easy to use, and scalable to the user’s system requirements. It is freely available for Linux on the web at https://github.com/KerstenDoering/PubMedPortable and for other operating systems as a virtual container. The approach was tested extensively and applied successfully in several projects. PMID:27706202

  16. A portable blood plasma clot micro-elastometry device based on resonant acoustic spectroscopy

    NASA Astrophysics Data System (ADS)

    Krebs, C. R.; Li, Ling; Wolberg, Alisa S.; Oldenburg, Amy L.

    2015-07-01

    Abnormal blood clot stiffness is an important indicator of coagulation disorders arising from a variety of cardiovascular diseases and drug treatments. Here, we present a portable instrument for elastometry of microliter volume blood samples based upon the principle of resonant acoustic spectroscopy, where a sample of well-defined dimensions exhibits a fundamental longitudinal resonance mode proportional to the square root of the Young's modulus. In contrast to commercial thromboelastography, the resonant acoustic method offers improved repeatability and accuracy due to the high signal-to-noise ratio of the resonant vibration. We review the measurement principles and the design of a magnetically actuated microbead force transducer applying between 23 pN and 6.7 nN, providing a wide dynamic range of elastic moduli (3 Pa-27 kPa) appropriate for measurement of clot elastic modulus (CEM). An automated and portable device, the CEMport, is introduced and implemented using a 2 nm resolution displacement sensor with demonstrated accuracy and precision of 3% and 2%, respectively, of CEM in biogels. Importantly, the small strains (<0.13%) and low strain rates (<1/s) employed by the CEMport maintain a linear stress-to-strain relationship which provides a perturbative measurement of the Young's modulus. Measurements of blood plasma CEM versus heparin concentration show that CEMport is sensitive to heparin levels below 0.050 U/ml, which suggests future applications in sensing heparin levels of post-surgical cardiopulmonary bypass patients. The portability, high accuracy, and high precision of this device enable new clinical and animal studies for associating CEM with blood coagulation disorders, potentially leading to improved diagnostics and therapeutic monitoring.

  17. A portable blood plasma clot micro-elastometry device based on resonant acoustic spectroscopy.

    PubMed

    Krebs, C R; Li, Ling; Wolberg, Alisa S; Oldenburg, Amy L

    2015-07-01

    Abnormal blood clot stiffness is an important indicator of coagulation disorders arising from a variety of cardiovascular diseases and drug treatments. Here, we present a portable instrument for elastometry of microliter volume blood samples based upon the principle of resonant acoustic spectroscopy, where a sample of well-defined dimensions exhibits a fundamental longitudinal resonance mode proportional to the square root of the Young's modulus. In contrast to commercial thromboelastography, the resonant acoustic method offers improved repeatability and accuracy due to the high signal-to-noise ratio of the resonant vibration. We review the measurement principles and the design of a magnetically actuated microbead force transducer applying between 23 pN and 6.7 nN, providing a wide dynamic range of elastic moduli (3 Pa-27 kPa) appropriate for measurement of clot elastic modulus (CEM). An automated and portable device, the CEMport, is introduced and implemented using a 2 nm resolution displacement sensor with demonstrated accuracy and precision of 3% and 2%, respectively, of CEM in biogels. Importantly, the small strains (<0.13%) and low strain rates (<1/s) employed by the CEMport maintain a linear stress-to-strain relationship which provides a perturbative measurement of the Young's modulus. Measurements of blood plasma CEM versus heparin concentration show that CEMport is sensitive to heparin levels below 0.050 U/ml, which suggests future applications in sensing heparin levels of post-surgical cardiopulmonary bypass patients. The portability, high accuracy, and high precision of this device enable new clinical and animal studies for associating CEM with blood coagulation disorders, potentially leading to improved diagnostics and therapeutic monitoring.

  18. Inflammatory biomarkers responses after acute whole body vibration in fibromyalgia.

    PubMed

    Ribeiro, V G C; Mendonça, V A; Souza, A L C; Fonseca, S F; Camargos, A C R; Lage, V K S; Neves, C D C; Santos, J M; Teixeira, L A C; Vieira, E L M; Teixeira Junior, A L; Mezêncio, B; Fernandes, J S C; Leite, H R; Poortmans, J R; Lacerda, A C R

    2018-03-01

    The aims of this study were 1) to characterize the intensity of the vibration stimulation in women diagnosed with fibromyalgia (FM) compared to a control group of healthy women (HW) matched by age and anthropometric parameters, and 2) to investigate the effect of a single session of whole body vibration (WBV) on inflammatory responses. Levels of adipokines, soluble tumor necrosis factor receptors (sTNFr1, sTNFr2), and brain-derived neurotrophic factor (BDNF) were determined by enzyme-linked immunosorbent assay. Oxygen consumption (VO2) was estimated by a portable gas analysis system, heart rate (HR) was measured using a HR monitor, and perceived exertion (RPE) was evaluated using the Borg scale of perceived exertion. Acutely mild WBV increased VO2 and HR similarly in both groups. There was an interaction (disease vs vibration) in RPE (P=0.0078), showing a higher RPE in FM compared to HW at rest, which further increased in FM after acute WBV, whereas it remained unchanged in HW. In addition, there was an interaction (disease vs vibration) in plasma levels of adiponectin (P=0.0001), sTNFR1 (P=0.000001), sTNFR2 (P=0.0052), leptin (P=0.0007), resistin (P=0.0166), and BDNF (P=0.0179). In conclusion, a single acute session of mild and short WBV can improve the inflammatory status in patients with FM, reaching values close to those of matched HW at their basal status. The neuroendocrine mechanism seems to be an exercise-induced modulation towards greater adaptation to stress response in these patients.

  19. Inflammatory biomarkers responses after acute whole body vibration in fibromyalgia

    PubMed Central

    Ribeiro, V.G.C.; Mendonça, V.A.; Souza, A.L.C.; Fonseca, S.F.; Camargos, A.C.R.; Lage, V.K.S.; Neves, C.D.C.; Santos, J.M.; Teixeira, L.A.C.; Vieira, E.L.M.; Teixeira, A.L.; Mezêncio, B.; Fernandes, J.S.C.; Leite, H.R.; Poortmans, J.R.; Lacerda, A.C.R.

    2018-01-01

    The aims of this study were 1) to characterize the intensity of the vibration stimulation in women diagnosed with fibromyalgia (FM) compared to a control group of healthy women (HW) matched by age and anthropometric parameters, and 2) to investigate the effect of a single session of whole body vibration (WBV) on inflammatory responses. Levels of adipokines, soluble tumor necrosis factor receptors (sTNFr1, sTNFr2), and brain-derived neurotrophic factor (BDNF) were determined by enzyme-linked immunosorbent assay. Oxygen consumption (VO2) was estimated by a portable gas analysis system, heart rate (HR) was measured using a HR monitor, and perceived exertion (RPE) was evaluated using the Borg scale of perceived exertion. Acutely mild WBV increased VO2 and HR similarly in both groups. There was an interaction (disease vs vibration) in RPE (P=0.0078), showing a higher RPE in FM compared to HW at rest, which further increased in FM after acute WBV, whereas it remained unchanged in HW. In addition, there was an interaction (disease vs vibration) in plasma levels of adiponectin (P=0.0001), sTNFR1 (P=0.000001), sTNFR2 (P=0.0052), leptin (P=0.0007), resistin (P=0.0166), and BDNF (P=0.0179). In conclusion, a single acute session of mild and short WBV can improve the inflammatory status in patients with FM, reaching values close to those of matched HW at their basal status. The neuroendocrine mechanism seems to be an exercise-induced modulation towards greater adaptation to stress response in these patients. PMID:29513791

  20. Use of portable X-ray fluorescence spectrometry for environmental quality assessment of peri-urban agriculture.

    PubMed

    Weindorf, David C; Zhu, Yuanda; Chakraborty, Somsubhra; Bakr, Noura; Huang, Biao

    2012-01-01

    Urban expansion into traditional agricultural lands has augmented the potential for heavy metal contamination of soils. This study examined the utility of field portable X-ray fluorescence (PXRF) spectrometry for evaluating the environmental quality of sugarcane fields near two industrial complexes in Louisiana, USA. Results indicated that PXRF provided quality results of heavy metal levels comparable to traditional laboratory analysis. When coupled with global positioning system technology, the use of PXRF allows for on-site interpolation of heavy metal levels in a matter of minutes. Field portable XRF was shown to be an effective tool for rapid assessment of heavy metals in soils of peri-urban agricultural areas.

  1. Note: A portable Raman analyzer for microfluidic chips based on a dichroic beam splitter for integration of imaging and signal collection light paths

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geng, Yijia; Xu, Shuping; Xu, Weiqing, E-mail: xuwq@jlu.edu.cn

    An integrated and portable Raman analyzer featuring an inverted probe fixed on a motor-driving adjustable optical module was designed for the combination of a microfluidic system. It possesses a micro-imaging function. The inverted configuration is advantageous to locate and focus microfluidic channels. Different from commercial micro-imaging Raman spectrometers using manual switchable light path, this analyzer adopts a dichroic beam splitter for both imaging and signal collection light paths, which avoids movable parts and improves the integration and stability of optics. Combined with surface-enhanced Raman scattering technique, this portable Raman micro-analyzer is promising as a powerful tool for microfluidic analytics.

  2. Control issues of microgravity vibration isolation

    NASA Technical Reports Server (NTRS)

    Knospe, Carl R.; Hampton, Richard D.

    1991-01-01

    Active vibration isolation systems contemplated for microgravity space experiments may be designed to reach given performance requirements in a variety of ways. An analogy to passive isolation systems proves to be illustrative but lacks the flexibility as a design tool of a control systems approach and may lead to poor design. Control theory as applied to vibration isolation is reviewed and passive analogies discussed.

  3. Portable smartphone based quantitative phase microscope

    NASA Astrophysics Data System (ADS)

    Meng, Xin; Tian, Xiaolin; Yu, Wei; Kong, Yan; Jiang, Zhilong; Liu, Fei; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2018-01-01

    To realize portable device with high contrast imaging capability, we designed a quantitative phase microscope using transport of intensity equation method based on a smartphone. The whole system employs an objective and an eyepiece as imaging system and a cost-effective LED as illumination source. A 3-D printed cradle is used to align these components. Images of different focal planes are captured by manual focusing, followed by calculation of sample phase via a self-developed Android application. To validate its accuracy, we first tested the device by measuring a random phase plate with known phases, and then red blood cell smear, Pap smear, broad bean epidermis sections and monocot root were also measured to show its performance. Owing to its advantages as accuracy, high-contrast, cost-effective and portability, the portable smartphone based quantitative phase microscope is a promising tool which can be future adopted in remote healthcare and medical diagnosis.

  4. Portable Parallel Programming for the Dynamic Load Balancing of Unstructured Grid Applications

    NASA Technical Reports Server (NTRS)

    Biswas, Rupak; Das, Sajal K.; Harvey, Daniel; Oliker, Leonid

    1999-01-01

    The ability to dynamically adapt an unstructured -rid (or mesh) is a powerful tool for solving computational problems with evolving physical features; however, an efficient parallel implementation is rather difficult, particularly from the view point of portability on various multiprocessor platforms We address this problem by developing PLUM, tin automatic anti architecture-independent framework for adaptive numerical computations in a message-passing environment. Portability is demonstrated by comparing performance on an SP2, an Origin2000, and a T3E, without any code modifications. We also present a general-purpose load balancer that utilizes symmetric broadcast networks (SBN) as the underlying communication pattern, with a goal to providing a global view of system loads across processors. Experiments on, an SP2 and an Origin2000 demonstrate the portability of our approach which achieves superb load balance at the cost of minimal extra overhead.

  5. Method for Vibration Response Simulation and Sensor Placement Optimization of a Machine Tool Spindle System with a Bearing Defect

    PubMed Central

    Cao, Hongrui; Niu, Linkai; He, Zhengjia

    2012-01-01

    Bearing defects are one of the most important mechanical sources for vibration and noise generation in machine tool spindles. In this study, an integrated finite element (FE) model is proposed to predict the vibration responses of a spindle bearing system with localized bearing defects and then the sensor placement for better detection of bearing faults is optimized. A nonlinear bearing model is developed based on Jones' bearing theory, while the drawbar, shaft and housing are modeled as Timoshenko's beam. The bearing model is then integrated into the FE model of drawbar/shaft/housing by assembling equations of motion. The Newmark time integration method is used to solve the vibration responses numerically. The FE model of the spindle-bearing system was verified by conducting dynamic tests. Then, the localized bearing defects were modeled and vibration responses generated by the outer ring defect were simulated as an illustration. The optimization scheme of the sensor placement was carried out on the test spindle. The results proved that, the optimal sensor placement depends on the vibration modes under different boundary conditions and the transfer path between the excitation and the response. PMID:23012514

  6. A two scale modeling and computational framework for vibration-induced Raynaud syndrome.

    PubMed

    Hua, Yue; Lemerle, Pierre; Ganghoffer, Jean-François

    2017-07-01

    Hand-Arm Vibration syndrome (HAVS), usually caused by long-term use of hand-held power tools, can in certain manifestations alter the peripheral blood circulation in the hand-arm region. HAVS typically occurs after exposure to cold, causing an abnormally strong vasoconstriction of blood vessels. A pathoanatomical mechanism suggests that a reduction of the lumen of the blood vessels in VWF (Vibration White Finger) subjects, due to either hypertrophy or thickening of the vessel wall, may be at the origin of the disease. However, the direct and indirect effects of the load of the hand-held tools on the structure of blood vessels remain controversial:.one hypothesis is the mechanical action of vibration on the local acral dysregulation and/or on the vessel histomorphological modifications. Another hypothesis is the participation of the sympathetic nervous system to this dysregulation. In this paper, we assume the modifications as mechanobiological growth and the load-effect relationship may be interpreted as directly or indirectly induced. This work is the first attempt to model the effect of vibration through soft tissues onto the distal capillaries, addressing the double paradigm of multi space-time scales, i.e. low period vibration versus high time constant of the growth phenomenon as well as vibrations propagating in the macroscopic tissue including the microscopic capillary structures subjected to a pathological microstructural evolution. The objective is to lay down the theoretical basis of growth modeling for the small distal artery, with the ability to predict the geometrical and structural changes of the arterial walls caused by vibration exposure. We adopt the key idea of splitting the problem into one global vibration problem at the macroscopic scale and one local growth problem at the micro level. The macroscopic hyperelastic viscous dynamic model of the fingertip cross-section is validated by fitting experimental data. It is then used in steady-state vibration conditions to predict the mechanical fields in the close vicinity of capillaries. The space scale transfer from macroscopic to microscopic levels is ensured by considering a representative volume element (RVE) embedding a single capillary in its center. The vibrations emitted by the hand held power tool are next linked to the capillary growth through the adopted biomechanical growth model at the capillary level. The obtained results show that vibrations induce an increase of the thickness of the capillary's wall, thereby confirming the scenario of vibrations induced reduction of the lumen of blood vessels. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Oxygen consumption and heart rate during repeated squatting exercises with or without whole-body vibration in the elderly.

    PubMed

    Avelar, Núbia Cp; Simão, Adriano P; Tossige-Gomes, Rosalina; Neves, Camila Dc; Mezencio, Bruno; Szmuchrowski, Leszek; Coimbra, Cândido C; Lacerda, Ana Cr

    2011-12-01

    Avelar, NCP, Simão, AP, Tossige-Gomes, R, Neves, CDC, Mezencio, B, Szmuchrowski, L, Coimbra, CC, and Lacerda, ACR. Oxygen consumption and heart rate during repeated squatting exercises with or without whole-body vibration in the elderly. J Strength Cond Res 25(12): 3495-3500, 2011-The aim of this study was to investigate whether vibration plus squatting would increase cardiovascular demand to the optimal exercise limits needed for the prescription of cardiovascular training. Oxygen consumption, measured breath by breath by a portable gas analysis system, and heart rate (HR), measured using an HR monitor, were evaluated in 18 elderly individuals, 15 women and 3 men with a mean age of 72 ± 6 years. These variables were measured simultaneously and at the same time points in each subject during rest and randomly during the performance of squatting exercises (8 series of 40 seconds, with 40 seconds of rest between series of performing squats in 3-second cycles with 10-60° of flexion, a total of 5 repetitions for 40 seconds) with or without vibration at a frequency of 40 Hz and amplitude of 4 mm, separated by at least 1 day. Associating whole-body vibration with squatting exercise resulted in an additional increase of around 20% in oxygen consumption and 7.5% in the HR recorded during exercise. However, during squatting exercise with vibration, the increase achieved in oxygen consumption was limited to around 2 metabolic equivalents, and mean HR represented around 56% of the predicted maximum HR for age. The results of this study show that, despite the fact that vibration increased oxygen consumption and HR during the performance of squatting exercise, the minimum standards of intensity for the prescription of physical exercise with the specific objective of improving cardiorespiratory fitness were not achieved. Therefore, a protocol such as that used in the study does not meet the threshold for cardiovascular training prescription.

  8. Accurate Prediction of Motor Failures by Application of Multi CBM Tools: A Case Study

    NASA Astrophysics Data System (ADS)

    Dutta, Rana; Singh, Veerendra Pratap; Dwivedi, Jai Prakash

    2018-02-01

    Motor failures are very difficult to predict accurately with a single condition-monitoring tool as both electrical and the mechanical systems are closely related. Electrical problem, like phase unbalance, stator winding insulation failures can, at times, lead to vibration problem and at the same time mechanical failures like bearing failure, leads to rotor eccentricity. In this case study of a 550 kW blower motor it has been shown that a rotor bar crack was detected by current signature analysis and vibration monitoring confirmed the same. In later months in a similar motor vibration monitoring predicted bearing failure and current signature analysis confirmed the same. In both the cases, after dismantling the motor, the predictions were found to be accurate. In this paper we will be discussing the accurate predictions of motor failures through use of multi condition monitoring tools with two case studies.

  9. Design, construction and validation of a portable care system for the daily telerehabiliatation of gait.

    PubMed

    Giansanti, Daniele; Morelli, Sandra; Maccioni, Giovanni; Brocco, Monica

    2013-10-01

    When designing a complete system of daily-telerehabilitation it should be borne in mind that properly designed methodologies should be furnished for patients to execute specific motion tasks and for care givers to assess the relevant parameters. Whether in hospital or at home, the system should feature two basic elements: (a) instrumented and walking aids or supports, (b) equipment for the assessment of parameters. Being gait the focus, the idea was to design, construct and validate - as an alternative to the complex and expensive instruments currently used - a simple, portable kit that may be easily interfaced/integrated with the most common mechanical tools used in motion rehabilitation (instrumented walkways, aids, supports), with feedback to both patient for self-monitoring and trainer/therapist (present or remote) for clinical reporting. The proposed system consists of: one step-counter, three couples of photo-emitter detectors, one central unit for collecting and processing the telemetrically transmitted data; a software interface on a dedicated PC and a network adapter. The system has been successfully validated in a clinical application on two groups of 16 subjects at the 1st and 2nd level of the Tinetti test. The degree of acceptance by subjects and care-givers was high. The system was also successfully compared with an Inertial Measurement Unit, a de facto standard. The portable kit can be used with different rehabilitation tools and different ground rugosity. The advantages are: (a) very low costs when compared with optoelectronic solutions and other portable solutions; (b) very high accuracy, also for subjects with imbalance problems; (c) good compatibility with any rehabilitative tool. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Integrating Oil Debris and Vibration Gear Damage Detection Technologies Using Fuzzy Logic

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Afjeh, Abdollah A.

    2002-01-01

    A diagnostic tool for detecting damage to spur gears was developed. Two different measurement technologies, wear debris analysis and vibration, were integrated into a health monitoring system for detecting surface fatigue pitting damage on gears. This integrated system showed improved detection and decision-making capabilities as compared to using individual measurement technologies. This diagnostic tool was developed and evaluated experimentally by collecting vibration and oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Test Rig. Experimental data were collected during experiments performed in this test rig with and without pitting. Results show combining the two measurement technologies improves the detection of pitting damage on spur gears.

  11. Spiral Bevel Gear Damage Detection Using Decision Fusion Analysis

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Handschuh, Robert F.; Afjeh, Abdollah A.

    2002-01-01

    A diagnostic tool for detecting damage to spiral bevel gears was developed. Two different monitoring technologies, oil debris analysis and vibration, were integrated using data fusion into a health monitoring system for detecting surface fatigue pitting damage on gears. This integrated system showed improved detection and decision-making capabilities as compared to using individual monitoring technologies. This diagnostic tool was evaluated by collecting vibration and oil debris data from fatigue tests performed in the NASA Glenn Spiral Bevel Gear Fatigue Rigs. Data was collected during experiments performed in this test rig when pitting damage occurred. Results show that combining the vibration and oil debris measurement technologies improves the detection of pitting damage on spiral bevel gears.

  12. Ultrasonically assisted turning of aviation materials: simulations and experimental study.

    PubMed

    Babitsky, V I; Mitrofanov, A V; Silberschmidt, V V

    2004-04-01

    Ultrasonically assisted turning of modern aviation materials is conducted with ultrasonic vibration (frequency f approximately 20 kHz, amplitude a approximately 15 microm) superimposed on the cutting tool movement. An autoresonant control system is used to maintain the stable nonlinear resonant mode of vibration throughout the cutting process. Experimental comparison of roughness and roundness for workpieces machined conventionally and with the superimposed ultrasonic vibration, results of high-speed filming of the turning process and nanoindentation analyses of the microstructure of the machined material are presented. The suggested finite-element model provides numerical comparison between conventional and ultrasonic turning of Inconel 718 in terms of stress/strain state, cutting forces and contact conditions at the workpiece/tool interface.

  13. Portable duplex ultrasonography: A diagnostic and decision-making tool in reconstructive microsurgery.

    PubMed

    Gravvanis, Andreas; Karakitsos, Dimitrios; Dimitriou, Vasilios; Zogogiannis, Ioannis; Katsikeris, Nick; Karabinis, Andreas; Tsoutsos, Dimosthenis

    2010-07-01

    Unidirectional Doppler is a common diagnostic tool by the Reconstructive Microsurgeons; however, it may generate false signals and surely provides less imaging data as compared to duplex ultrasonography. We have reviewed the use of Portable Duplex Ultrasonography (PDU) in 16 patients who underwent complex soft-tissue/bone reconstruction, aiming to determine its role in the design and management of free tissue transfer. According to our data, there were modifications either of the surgical plan and/or of patient's management, based on PDU findings, in 10 out of 16 patients (62.5%). The use of ultrasound directed to subtle modifications in three patients (19%), but to significant changes of the surgical plan in four patients (25%). Also, the use of ultrasound improved significantly the postoperative management in three patients (19%). Thus, significant impact of PDU in patient's treatment was recorded in 44% of cases. Portable ultrasound represents generally available method for preoperative, intraoperative, and postoperative diagnosis and decision-making in free tissue transfer, hence could replace in the near future the unidirectional Doppler in the hands of Microsurgeons. (c) 2010 Wiley-Liss, Inc.

  14. 29 CFR 1926.303 - Abrasive wheels and tools.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and tools. (a) Power. All grinding machines shall be supplied with sufficient power to maintain the spindle speed at safe levels under all conditions of normal operation. (b) Guarding. (1) Grinding machines..., nut, and outer flange may be exposed on machines designed as portable saws. (c) Use of abrasive wheels...

  15. 29 CFR 1926.303 - Abrasive wheels and tools.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and tools. (a) Power. All grinding machines shall be supplied with sufficient power to maintain the spindle speed at safe levels under all conditions of normal operation. (b) Guarding. (1) Grinding machines..., nut, and outer flange may be exposed on machines designed as portable saws. (c) Use of abrasive wheels...

  16. 29 CFR 1926.303 - Abrasive wheels and tools.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and tools. (a) Power. All grinding machines shall be supplied with sufficient power to maintain the spindle speed at safe levels under all conditions of normal operation. (b) Guarding. (1) Grinding machines..., nut, and outer flange may be exposed on machines designed as portable saws. (c) Use of abrasive wheels...

  17. Approaches to decrease the level of parasitic noise over vibroacoustic channel in terms of configuring information security tools

    NASA Astrophysics Data System (ADS)

    Ivanov, A. V.; Reva, I. L.; Babin, A. A.

    2018-04-01

    The article deals with influence of various ways to place vibration transmitters on efficiency of rooms safety for negotiations. Standing for remote vibration listening of window glass, electro-optical channel, the most typical technical channel of information leakage, was investigated. The modern system “Sonata-AB” of 4B model is used as an active protection tool. Factors influencing on security tools configuration efficiency have been determined. The results allow utilizer to reduce masking interference level as well as parasitic noise with keeping properties of room safety.

  18. Ultrasonic Apparatus for Pulverizing Brittle Material

    NASA Technical Reports Server (NTRS)

    Sherrit, Stewart; Bao, Xiaoqi; Bar-Cohen, Yoseph; Dolgin, Benjamin; Chang, Zensheu

    2004-01-01

    The figure depicts an apparatus that pulverizes brittle material by means of a combination of ultrasonic and sonic vibration, hammering, and abrasion. The basic design of the apparatus could be specialized to be a portable version for use by a geologist in collecting powdered rock samples for analysis in the field or in a laboratory. Alternatively, a larger benchtop version could be designed for milling and mixing of precursor powders for such purposes as synthesis of ceramic and other polycrystalline materials or preparing powder samples for x-ray diffraction or x-ray fluorescence measurements to determine crystalline structures and compositions. Among the most attractive characteristics of this apparatus are its light weight and the ability to function without need for a large preload or a large power supply: It has been estimated that a portable version could have a mass <0.5 kg, would consume less than 1 W h of energy in milling a 1-cm3 volume of rock, and could operate at a preload <10 N. The basic design and principle of operation of this apparatus are similar to those of other apparatuses described in a series of prior NASA Tech Briefs articles, the two most relevant being Ultrasonic/ Sonic Drill/Corers With Integrated Sensors (NPO-20856), Vol. 25, No. 1 (January 2001), page 38 and Ultrasonic/ Sonic Mechanisms for Deep Drilling and Coring (NPO-30291), Vol. 27, No. 9 (September 2003), page 65. As before, vibrations are excited by means of a piezoelectric actuator, an ultrasonic horn, and a mass that is free to move axially over a limited range. As before, the ultrasonic harmonic motion of the horn drives the free-mass in a combination of ultrasonic harmonic and lower-frequency hammering motion. In this case, the free-mass is confined within a hollow cylinder that serves as a crushing chamber, and the free-mass serves as a crushing or milling tool. The hammering of the free-mass against a material sample at the lower end of the chamber grinds the sample into powder in a relatively short time. The restriction of the free-mass to axial motion only makes the grinding very efficient. The free-mass can be fabricated to have teeth on its lower face to enhance the grinding effect. Optionally, there can be a hole at the bottom of the chamber covered with a sieve to tailor the size distribution of the powder leaving the crushing chamber.

  19. Design and implementation of a smartphone-based portable ultrasound pulsed-wave Doppler device for blood flow measurement.

    PubMed

    Huang, Chih-Chung; Lee, Po-Yang; Chen, Pay-Yu; Liu, Ting-Yu

    2012-01-01

    Blood flow measurement using Doppler ultrasound has become a useful tool for diagnosing cardiovascular diseases and as a physiological monitor. Recently, pocket-sized ultrasound scanners have been introduced for portable diagnosis. The present paper reports the implementation of a portable ultrasound pulsed-wave (PW) Doppler flowmeter using a smartphone. A 10-MHz ultrasonic surface transducer was designed for the dynamic monitoring of blood flow velocity. The directional baseband Doppler shift signals were obtained using a portable analog circuit system. After hardware processing, the Doppler signals were fed directly to a smartphone for Doppler spectrogram analysis and display in real time. To the best of our knowledge, this is the first report of the use of this system for medical ultrasound Doppler signal processing. A Couette flow phantom, consisting of two parallel disks with a 2-mm gap, was used to evaluate and calibrate the device. Doppler spectrograms of porcine blood flow were measured using this stand-alone portable device under the pulsatile condition. Subsequently, in vivo portable system verification was performed by measuring the arterial blood flow of a rat and comparing the results with the measurement from a commercial ultrasound duplex scanner. All of the results demonstrated the potential for using a smartphone as a novel embedded system for portable medical ultrasound applications. © 2012 IEEE

  20. Optimization of voltage output of energy harvesters with continuous mechanical rotation extracted from human motion (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Rashid, Evan; Hamidi, Armita; Tadesse, Yonas

    2017-04-01

    With increasing popularity of portable devices for outdoor activities, portable energy harvesting devices are coming into spot light. The next generation energy harvester which is called hybrid energy harvester can employ more than one mechanism in a single device to optimize portion of the energy that can be harvested from any source of waste energy namely motion, vibration, heat and etc. In spite of few recent attempts for creating hybrid portable devices, the level of output energy still needs to be improved with the intention of employing them in commercial electronic systems or further applications. Moreover, implementing a practical hybrid energy harvester in different application for further investigation is still challenging. This proposal is projected to incorporate a novel approach to maximize and optimize the voltage output of hybrid energy harvesters to achieve a greater conversion efficiency normalized by the total mass of the hybrid device than the simple arithmetic sum of the individual harvesting mechanisms. The energy harvester model previously proposed by Larkin and Tadesse [1] is used as a baseline and a continuous unidirectional rotation is incorporated to maximize and optimize the output. The device harvest mechanical energy from oscillatory motion and convert it to electrical energy through electromagnetic and piezoelectric systems. The new designed mechanism upgrades the device in a way that can harvest energy from both rotational and linear motions by using magnets. Likewise, the piezoelectric section optimized to harvest at least 10% more energy. To the end, the device scaled down for tested with different sources of vibrations in the immediate environment, including machinery operation, bicycle, door motion while opening and closing and finally, human motions. Comparing the results from literature proved that current device has capability to be employed in commercial small electronic devices for enhancement of battery usage or as a backup power source. [1] Larkin, Miles, and Yonas Tadesse. "HM-EH-RT: hybrid multimodal energy harvesting from rotational and translational motions." International Journal of Smart and Nano Materials 4.4 (2013): 257-285.

  1. Validity and inter-observer reliability of subjective hand-arm vibration assessments.

    PubMed

    Coenen, Pieter; Formanoy, Margriet; Douwes, Marjolein; Bosch, Tim; de Kraker, Heleen

    2014-07-01

    Exposure to mechanical vibrations at work (e.g., due to handling powered tools) is a potential occupational risk as it may cause upper extremity complaints. However, reliable and valid assessment methods for vibration exposure at work are lacking. Measuring hand-arm vibration objectively is often difficult and expensive, while often used information provided by manufacturers lacks detail. Therefore, a subjective hand-arm vibration assessment method was tested on validity and inter-observer reliability. In an experimental protocol, sixteen tasks handling powered tools were executed by two workers. Hand-arm vibration was assessed subjectively by 16 observers according to the proposed subjective assessment method. As a gold standard reference, hand-arm vibration was measured objectively using a vibration measurement device. Weighted κ's were calculated to assess validity, intra-class-correlation coefficients (ICCs) were calculated to assess inter-observer reliability. Inter-observer reliability of the subjective assessments depicting the agreement among observers can be expressed by an ICC of 0.708 (0.511-0.873). The validity of the subjective assessments as compared to the gold-standard reference can be expressed by a weighted κ of 0.535 (0.285-0.785). Besides, the percentage of exact agreement of the subjective assessment compared to the objective measurement was relatively low (i.e., 52% of all tasks). This study shows that subjectively assessed hand-arm vibrations are fairly reliable among observers and moderately valid. This assessment method is a first attempt to use subjective risk assessments of hand-arm vibration. Although, this assessment method can benefit from some future improvement, it can be of use in future studies and in field-based ergonomic assessments. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  2. Advanced Vibration Analysis Tool Developed for Robust Engine Rotor Designs

    NASA Technical Reports Server (NTRS)

    Min, James B.

    2005-01-01

    The primary objective of this research program is to develop vibration analysis tools, design tools, and design strategies to significantly improve the safety and robustness of turbine engine rotors. Bladed disks in turbine engines always feature small, random blade-to-blade differences, or mistuning. Mistuning can lead to a dramatic increase in blade forced-response amplitudes and stresses. Ultimately, this results in high-cycle fatigue, which is a major safety and cost concern. In this research program, the necessary steps will be taken to transform a state-of-the-art vibration analysis tool, the Turbo- Reduce forced-response prediction code, into an effective design tool by enhancing and extending the underlying modeling and analysis methods. Furthermore, novel techniques will be developed to assess the safety of a given design. In particular, a procedure will be established for using natural-frequency curve veerings to identify ranges of operating conditions (rotational speeds and engine orders) in which there is a great risk that the rotor blades will suffer high stresses. This work also will aid statistical studies of the forced response by reducing the necessary number of simulations. Finally, new strategies for improving the design of rotors will be pursued.

  3. Development and testing of an active boring bar for increased chatter immunity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Redmond, J.; Barney, P.

    Recent advances in smart materials have renewed interest in the development of improved manufacturing processes featuring sensing, processing, and active control. In particular, vibration suppression in metal cutting has received much attention because of its potential for enhancing part quality while reducing the time and cost of production. Although active tool clamps have been recently demonstrated, they are often accompanied by interfacing issues that limit their applicability to specific machines. Under the auspices of the Laboratory Directed Research and Development program, the project titled {open_quotes}Smart Cutting Tools for Precision Manufacturing{close_quotes} developed an alternative approach to active vibration control in machining.more » Using the boring process as a vehicle for exploration, a commercially available tool was modified to incorporate PZT stack actuators for active suppression of its bending modes. Since the modified tool requires no specialized mounting hardware, it can be readily mounted on many machines. Cutting tests conducted on a horizontal lathe fitted with a hardened steel workpiece verify that the actively damped boring bar yields significant vibration reduction and improved surface finishes as compared to an unmodified tool.« less

  4. Amplitude-cyclic frequency decomposition of vibration signals for bearing fault diagnosis based on phase editing

    NASA Astrophysics Data System (ADS)

    Barbini, L.; Eltabach, M.; Hillis, A. J.; du Bois, J. L.

    2018-03-01

    In rotating machine diagnosis different spectral tools are used to analyse vibration signals. Despite the good diagnostic performance such tools are usually refined, computationally complex to implement and require oversight of an expert user. This paper introduces an intuitive and easy to implement method for vibration analysis: amplitude cyclic frequency decomposition. This method firstly separates vibration signals accordingly to their spectral amplitudes and secondly uses the squared envelope spectrum to reveal the presence of cyclostationarity in each amplitude level. The intuitive idea is that in a rotating machine different components contribute vibrations at different amplitudes, for instance defective bearings contribute a very weak signal in contrast to gears. This paper also introduces a new quantity, the decomposition squared envelope spectrum, which enables separation between the components of a rotating machine. The amplitude cyclic frequency decomposition and the decomposition squared envelope spectrum are tested on real word signals, both at stationary and varying speeds, using data from a wind turbine gearbox and an aircraft engine. In addition a benchmark comparison to the spectral correlation method is presented.

  5. Vascular and nerve damage in workers exposed to vibrating tools. The importance of objective measurements of exposure time.

    PubMed

    Gerhardsson, Lars; Balogh, Istvan; Hambert, Per-Arne; Hjortsberg, Ulf; Karlsson, Jan-Erik

    2005-01-01

    The aim of the present study was to compare the development of vibration white fingers (VWF) in workers in relation to different ways of exposure estimation, and their relationship to the standard ISO 5349, annex A. Nineteen vibration exposed (grinding machines) male workers completed a questionnaire followed by a structured interview including questions regarding their estimated hand-held vibration exposure. Neurophysiological tests such as fractionated nerve conduction velocity in hands and arms, vibrotactile perception thresholds and temperature thresholds were determined. The subjective estimation of the mean daily exposure-time to vibrating tools was 192 min (range 18-480 min) among the workers. The estimated mean exposure time calculated from the consumption of grinding wheels was 42 min (range 18-60 min), approximately a four-fold overestimation (Wilcoxon's signed ranks test, p<0.001). Thus, objective measurements of the exposure time, related to the standard ISO 5349, which in this case were based on the consumption of grinding wheels, will in most cases give a better basis for adequate risk assessment than self-exposure assessment.

  6. Simulation of X-ray transient absorption for following vibrations in coherently ionized F2 molecules

    NASA Astrophysics Data System (ADS)

    Dutoi, Anthony D.; Leone, Stephen R.

    2017-01-01

    Femtosecond and attosecond X-ray transient absorption experiments are becoming increasingly sophisticated tools for probing nuclear dynamics. In this work, we explore and develop theoretical tools needed for interpretation of such spectra,in order to characterize the vibrational coherences that result from ionizing a molecule in a strong IR field. Ab initio data for F2 is combined with simulations of nuclear dynamics, in order to simulate time-resolved X-ray absorption spectra for vibrational wavepackets after coherent ionization at 0 K and at finite temperature. Dihalogens pose rather difficult electronic structure problems, and the issues encountered in this work will be reflective of those encountered with any core-valence excitation simulation when a bond is breaking. The simulations reveal a strong dependence of the X-ray absorption maximum on the locations of the vibrational wave packets. A Fourier transform of the simulated signal shows features at the overtone frequencies of both the neutral and the cation, which reflect spatial interferences of the vibrational eigenstates. This provides a direct path for implementing ultrafast X-ray spectroscopic methods to visualize coherent nuclear dynamics.

  7. Hand function in workers with hand-arm vibration syndrome.

    PubMed

    Cederlund, R; Isacsson, A; Lundborg, G

    1999-01-01

    Hand-arm vibration syndrome has been specially addressed in the Scandinavian countries in recent years, but the syndrome is still not sufficiently recognized in many countries. The object of this preliminary study was to describe the nature and character of vibration-induced impairment in the hands of exposed workers. Twenty symptomatic male workers (aged 28 to 65 years) subjected to vibration by hand-held tools were interviewed about subjective symptoms and activities of daily living and were assessed with a battery of objective tests for sensibility, dexterity, grip function, and grip strength. The test results were compared with normative data. The majority of patients complained of cold intolerance, numbness, pain, sensory impairment, and difficulties in handling manual tools and in handwriting. The various objective tests showed considerable variation in indications of pathologic outcome, revealing differences in sensitivity to detect impaired hand function. Semmes-Weinstein monofilament testing for perception of light touch-deep pressure sensation, the small-object shape identification test, and moving two-point discrimination testing for functional sensibility provided the most indications of pathologic outcomes. The authors conclude that vibration-exposed patients present considerable impairment in hand function.

  8. The Shock and Vibration Digest. Volume 15, Number 7

    DTIC Science & Technology

    1983-07-01

    systems noise -- for tant analytical tool, the statistical energy analysis example, from a specific metal, chain driven, con- method, has been the subject...34Experimental Determination of Vibration Parameters Re- ~~~quired in the Statistical Energy Analysis Meth- .,i. 31. Dubowsky, S. and Morris, T.L., "An...34Coupling Loss Factors for 55. Upton, R., "Sound Intensity -. A Powerful New Statistical Energy Analysis of Sound Trans- Measurement Tool," S/V, Sound

  9. 41 CFR 50-204.5 - Machine guarding.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... usually require point of operation guarding: Guillotine cutters. Shears. Alligator shears. Power presses. Milling machines. Power saws. Jointers. Portable power tools. Forming rolls and calenders. (d) Revolving...

  10. Ultrasonic Abrasive Removal Of EDM Recast

    NASA Technical Reports Server (NTRS)

    Mandel, Johnny L.; Jacobson, Marlowe S.

    1990-01-01

    Ultrasonic abrasive process removes layer of recast material generated during electrical-discharge machining (EDM) of damper pocket on turbine blade. Form-fitted tool vibrated ultrasonically in damper pocket from which material removed. Vibrations activate abrasive in pocket. Amount of material removed controlled precisely.

  11. Hand portable thin-layer chromatography system

    DOEpatents

    Haas, Jeffrey S.; Kelly, Fredrick R.; Bushman, John F.; Wiefel, Michael H.; Jensen, Wayne A.

    2000-01-01

    A hand portable, field-deployable thin-layer chromatography (TLC) unit and a hand portable, battery-operated unit for development, illumination, and data acquisition of the TLC plates contain many miniaturized features that permit a large number of samples to be processed efficiently. The TLC unit includes a solvent tank, a holder for TLC plates, and a variety of tool chambers for storing TLC plates, solvent, and pipettes. After processing in the TLC unit, a TLC plate is positioned in a collapsible illumination box, where the box and a CCD camera are optically aligned for optimal pixel resolution of the CCD images of the TLC plate. The TLC system includes an improved development chamber for chemical development of TLC plates that prevents solvent overflow.

  12. TBI Assessment of Readiness Using a Gait Evaluation Test (TARGET): Development of a Portable mTBI Screening Device

    DTIC Science & Technology

    2017-05-01

    AWARD NUMBER: W81XWH-15-1-0094 TITLE: TBI Assessment of Readiness Using a Gait Evaluation Test (TARGET): Development of a Portable mTBI Screening...Annual 3. DATES COVERED 1 May 2016 - 30 Apr 2017 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER “TBI Assessment of Readiness Using a Gait Evaluation ...service members sustaining some form of traumatic brain injury (TBI) over the past 14 years, the lack of an objective measurement tool for evaluation

  13. An Analysis of the INGRES Database Management System Applications Program Development Tools and Programming Environment

    DTIC Science & Technology

    1986-12-01

    Position cursor over the naBe of a report, then use the appropriate enu iteffl to perforn an operation on that report. Naae Owner RBF? Last changed...LANGUAGE- INDEPENDENT, PORTABLE FILE ACCESS SY STEM A MODEL FOR AUTOMATIC FILE AND PROGRAM DESIGN IN BUSINE SS APPLICATION SYSTEM GENERALLY APPLICABLE...Article Description Year: 1988 Title: FLASH : A LANGUAGE- INDEPENDENT, PORTABLE FILE ACCESS SY STEM Authors: ALLCHIN.J.E., KaLER.A.H., WIEDERHOL.D.G

  14. Portable Biomarker Detection with Magnetic Nanotags

    PubMed Central

    Hall, Drew A.; Wang, Shan X.; Murmann, Boris; Gaster, Richard S.

    2012-01-01

    This paper presents a hand-held, portable biosensor platform for quantitative biomarker measurement. By combining magnetic nanoparticle (MNP) tags with giant magnetoresistive (GMR) spin-valve sensors, the hand-held platform achieves highly sensitive (picomolar) and specific biomarker detection in less than 20 minutes. The rapid analysis and potential low cost make this technology ideal for point-of-care (POC) diagnostics. Furthermore, this platform is able to detect multiple biomarkers simultaneously in a single assay, creating a promising diagnostic tool for a vast number of applications. PMID:22495252

  15. Application of a multi-beam vibrometer on industrial components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bendel, Karl

    2014-05-27

    Laser Doppler vibrometry is a well proven tool for the non-contact measurement of vibration. The scanning of several measurement points allows to visualize the deflection shape of the component, ideally a 3D-operating deflection shape, if a 3-D scanner is applied. Measuring the points sequentially, however, requires stationary behavior during the measurement time. This cannot be guaranteed for many real objects. Therefore, a multipoint laser Doppler vibrometer has been developed by Polytec and the University of Stuttgart with Bosch as industrial partner. A short description of the measurement system is given. Applications for the parallel measurement of the vibration of severalmore » points are shown for non-stationary vibrating Bosch components such as power-tools or valves.« less

  16. Instructional Support System--Occupational Education. Building Industries Occupations.

    ERIC Educational Resources Information Center

    Abramson, Theodore; And Others

    The modules which make up the bulk of this report are the result of a two-week workshop at which thirteen building industries occupations teachers worked toward the development of a student outcome oriented curriculum. These modules are divided into the following occupational units: (1) carpentry (containing hand tools; portable power tools;…

  17. Assessment in the Digital Age: An Overview of Online Tools and Considerations for School Psychologists and School Counsellors

    ERIC Educational Resources Information Center

    Jellins, Laura

    2015-01-01

    With recent developments in technology, online tests and digital tools offer school psychologists and school counsellors alternate modes of assessment. These new technologies have the potential to increase accessibility to tests (through greater portability), allow school psychologists and school counsellors to service more students (through…

  18. A Study on Immersion and Presence of a Portable Hand Haptic System for Immersive Virtual Reality

    PubMed Central

    Kim, Mingyu; Jeon, Changyu; Kim, Jinmo

    2017-01-01

    This paper proposes a portable hand haptic system using Leap Motion as a haptic interface that can be used in various virtual reality (VR) applications. The proposed hand haptic system was designed as an Arduino-based sensor architecture to enable a variety of tactile senses at low cost, and is also equipped with a portable wristband. As a haptic system designed for tactile feedback, the proposed system first identifies the left and right hands and then sends tactile senses (vibration and heat) to each fingertip (thumb and index finger). It is incorporated into a wearable band-type system, making its use easy and convenient. Next, hand motion is accurately captured using the sensor of the hand tracking system and is used for virtual object control, thus achieving interaction that enhances immersion. A VR application was designed with the purpose of testing the immersion and presence aspects of the proposed system. Lastly, technical and statistical tests were carried out to assess whether the proposed haptic system can provide a new immersive presence to users. According to the results of the presence questionnaire and the simulator sickness questionnaire, we confirmed that the proposed hand haptic system, in comparison to the existing interaction that uses only the hand tracking system, provided greater presence and a more immersive environment in the virtual reality. PMID:28513545

  19. Cloud-point detection using a portable thickness shear mode crystal resonator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mansure, A.J.; Spates, J.J.; Germer, J.W.

    1997-08-01

    The Thickness Shear Mode (TSM) crystal resonator monitors the crude oil by propagating a shear wave into the oil. The coupling of the shear wave and the crystal vibrations is a function of the viscosity of the oil. By driving the crystal with circuitry that incorporates feedback, it is possible to determine the change from Newtonian to non-Newtonian viscosity at the cloud point. A portable prototype TSM Cloud Point Detector (CPD) has performed flawlessly during field and lab tests proving the technique is less subjective or operator dependent than the ASTM standard. The TSM CPD, in contrast to standard viscositymore » techniques, makes the measurement in a closed container capable of maintaining up to 100 psi. The closed container minimizes losses of low molecular weight volatiles, allowing samples (25 ml) to be retested with the addition of chemicals. By cycling/thermal soaking the sample, the effects of thermal history can be investigated and eliminated as a source of confusion. The CPD is portable, suitable for shipping the field offices for use by personnel without special training or experience in cloud point measurements. As such, it can make cloud point data available without the delays and inconvenience of sending samples to special labs. The crystal resonator technology can be adapted to in-line monitoring of cloud point and deposition detection.« less

  20. A Study on Immersion and Presence of a Portable Hand Haptic System for Immersive Virtual Reality.

    PubMed

    Kim, Mingyu; Jeon, Changyu; Kim, Jinmo

    2017-05-17

    This paper proposes a portable hand haptic system using Leap Motion as a haptic interface that can be used in various virtual reality (VR) applications. The proposed hand haptic system was designed as an Arduino-based sensor architecture to enable a variety of tactile senses at low cost, and is also equipped with a portable wristband. As a haptic system designed for tactile feedback, the proposed system first identifies the left and right hands and then sends tactile senses (vibration and heat) to each fingertip (thumb and index finger). It is incorporated into a wearable band-type system, making its use easy and convenient. Next, hand motion is accurately captured using the sensor of the hand tracking system and is used for virtual object control, thus achieving interaction that enhances immersion. A VR application was designed with the purpose of testing the immersion and presence aspects of the proposed system. Lastly, technical and statistical tests were carried out to assess whether the proposed haptic system can provide a new immersive presence to users. According to the results of the presence questionnaire and the simulator sickness questionnaire, we confirmed that the proposed hand haptic system, in comparison to the existing interaction that uses only the hand tracking system, provided greater presence and a more immersive environment in the virtual reality.

  1. Feasibility of using portable, noninvasive pipe flowmeters and time totalizers for determining water use

    USGS Publications Warehouse

    Arvin, D.V.

    1992-01-01

    The feasibility of using time totalizers for determining water use was investigated by observing seven vibration time totalizers (VTT's) mounted at five sites. None of the units exhibited adverse effects from the heat, precipitation, or humidity associated with Indiana summers. One VTT was mounted at a public water-supply site where inductive time-totalizer measurements were available for comparison. The VTT agreed within 8 hours of the inductive time totalizer after 2,340 hours of pump operation. There were no mechanical prpblems with the VTT units used in this study.

  2. Research of Extension of the Life Cycle of Helicopter Rotor Blade in Hungary

    DTIC Science & Technology

    2003-02-01

    Radiography (DXR), and (iii) Vibration Diagnostics (VD) with Statistical Energy Analysis (SEA) were semi- simultaneously applied [1]. The used three...2.2. Vibration Diagnostics (VD)) Parallel to the NDT measurements the Statistical Energy Analysis (SEA) as a vibration diagnostical tool were...noises were analysed with a dual-channel real time frequency analyser (BK2035). In addition to the Statistical Energy Analysis measurement a small

  3. Molecular dynamics modeling of bonding two materials by atomic scale friction stir welding

    NASA Astrophysics Data System (ADS)

    Konovalenko S., Iv.; Konovalenko, Ig. S.; Psakhie, S. G.

    2017-12-01

    Molecular dynamics model of atomic scale friction stir welding has been developed. Formation of a butt joint between two crystallites was modeled by means of rotating rigid conical tool traveling along the butt joint line. The formed joint had an intermixed atomic structure composed of atoms initially belonged to the opposite mated piece of metal. Heat removal was modeled by adding the extra viscous force to peripheral atomic layers. This technique provides the temperature control in the tool-affected zone during welding. Auxiliary vibration action was added to the rotating tool. The model provides the variation of the tool's angular velocity, amplitude, frequency and direction of the auxiliary vibration action to provide modeling different welding modes.

  4. Comparison of various tool wear prediction methods during end milling of metal matrix composite

    NASA Astrophysics Data System (ADS)

    Wiciak, Martyna; Twardowski, Paweł; Wojciechowski, Szymon

    2018-02-01

    In this paper, the problem of tool wear prediction during milling of hard-to-cut metal matrix composite Duralcan™ was presented. The conducted research involved the measurements of acceleration of vibrations during milling with constant cutting conditions, and evaluation of the flank wear. Subsequently, the analysis of vibrations in time and frequency domain, as well as the correlation of the obtained measures with the tool wear values were conducted. The validation of tool wear diagnosis in relation to selected diagnostic measures was carried out with the use of one variable and two variables regression models, as well as with the application of artificial neural networks (ANN). The comparative analysis of the obtained results enable.

  5. Microfluidics-Based Lab-on-Chip Systems in DNA-Based Biosensing: An Overview

    PubMed Central

    Dutse, Sabo Wada; Yusof, Nor Azah

    2011-01-01

    Microfluidics-based lab-on-chip (LOC) systems are an active research area that is revolutionising high-throughput sequencing for the fast, sensitive and accurate detection of a variety of pathogens. LOCs also serve as portable diagnostic tools. The devices provide optimum control of nanolitre volumes of fluids and integrate various bioassay operations that allow the devices to rapidly sense pathogenic threat agents for environmental monitoring. LOC systems, such as microfluidic biochips, offer advantages compared to conventional identification procedures that are tedious, expensive and time consuming. This paper aims to provide a broad overview of the need for devices that are easy to operate, sensitive, fast, portable and sufficiently reliable to be used as complementary tools for the control of pathogenic agents that damage the environment. PMID:22163925

  6. Structural Dynamics of Electronic Systems

    NASA Astrophysics Data System (ADS)

    Suhir, E.

    2013-03-01

    The published work on analytical ("mathematical") and computer-aided, primarily finite-element-analysis (FEA) based, predictive modeling of the dynamic response of electronic systems to shocks and vibrations is reviewed. While understanding the physics of and the ability to predict the response of an electronic structure to dynamic loading has been always of significant importance in military, avionic, aeronautic, automotive and maritime electronics, during the last decade this problem has become especially important also in commercial, and, particularly, in portable electronics in connection with accelerated testing of various surface mount technology (SMT) systems on the board level. The emphasis of the review is on the nonlinear shock-excited vibrations of flexible printed circuit boards (PCBs) experiencing shock loading applied to their support contours during drop tests. At the end of the review we provide, as a suitable and useful illustration, the exact solution to a highly nonlinear problem of the dynamic response of a "flexible-and-heavy" PCB to an impact load applied to its support contour during drop testing.

  7. Micro acoustic spectrum analyzer

    DOEpatents

    Schubert, W. Kent; Butler, Michael A.; Adkins, Douglas R.; Anderson, Larry F.

    2004-11-23

    A micro acoustic spectrum analyzer for determining the frequency components of a fluctuating sound signal comprises a microphone to pick up the fluctuating sound signal and produce an alternating current electrical signal; at least one microfabricated resonator, each resonator having a different resonant frequency, that vibrate in response to the alternating current electrical signal; and at least one detector to detect the vibration of the microfabricated resonators. The micro acoustic spectrum analyzer can further comprise a mixer to mix a reference signal with the alternating current electrical signal from the microphone to shift the frequency spectrum to a frequency range that is a better matched to the resonant frequencies of the microfabricated resonators. The micro acoustic spectrum analyzer can be designed specifically for portability, size, cost, accuracy, speed, power requirements, and use in a harsh environment. The micro acoustic spectrum analyzer is particularly suited for applications where size, accessibility, and power requirements are limited, such as the monitoring of industrial equipment and processes, detection of security intrusions, or evaluation of military threats.

  8. Development of a flexible and bendable vibrotactile actuator based on wave-shaped poly(vinyl chloride)/acetyl tributyl citrate gels for wearable electronic devices

    NASA Astrophysics Data System (ADS)

    Park, Won-Hyeong; Bae, Jin Woo; Shin, Eun-Jae; Kim, Sang-Youn

    2016-11-01

    The paradigm of consumer electronic devices is being shifted from rigid hand-held devices to flexible/wearable devices in search of benefits such as enhanced usability and portability, excellent wear characteristics, and more functions in less space. However, the fundamental incompatibility of flexible/wearable devices and a rigid actuator brought forth a new issue obstructing commercialization of flexible/wearable devices. In this paper, we propose a new wave-shaped eco-friendly PVC gel, and a new flexible and bendable vibrotactile actuator that could easily be applied to wearable electronic devices. We explain the vibration mechanism of the proposed vibrotactile actuator and investigate its influence on the content of plasticizer for the performance of the proposed actuator. An experiment for measuring vibrational amplitude was conducted over a wide frequency range. The experiment clearly showed that the proposed vibrotactile actuator could create a variety of haptic sensations in wearable devices.

  9. A portable blood plasma clot micro-elastometry device based on resonant acoustic spectroscopy

    PubMed Central

    Krebs, C. R.; Li, Ling; Wolberg, Alisa S.; Oldenburg, Amy L.

    2015-01-01

    Abnormal blood clot stiffness is an important indicator of coagulation disorders arising from a variety of cardiovascular diseases and drug treatments. Here, we present a portable instrument for elastometry of microliter volume blood samples based upon the principle of resonant acoustic spectroscopy, where a sample of well-defined dimensions exhibits a fundamental longitudinal resonance mode proportional to the square root of the Young’s modulus. In contrast to commercial thromboelastography, the resonant acoustic method offers improved repeatability and accuracy due to the high signal-to-noise ratio of the resonant vibration. We review the measurement principles and the design of a magnetically actuated microbead force transducer applying between 23 pN and 6.7 nN, providing a wide dynamic range of elastic moduli (3 Pa–27 kPa) appropriate for measurement of clot elastic modulus (CEM). An automated and portable device, the CEMport, is introduced and implemented using a 2 nm resolution displacement sensor with demonstrated accuracy and precision of 3% and 2%, respectively, of CEM in biogels. Importantly, the small strains (<0.13%) and low strain rates (<1/s) employed by the CEMport maintain a linear stress-to-strain relationship which provides a perturbative measurement of the Young’s modulus. Measurements of blood plasma CEM versus heparin concentration show that CEMport is sensitive to heparin levels below 0.050 U/ml, which suggests future applications in sensing heparin levels of post-surgical cardiopulmonary bypass patients. The portability, high accuracy, and high precision of this device enable new clinical and animal studies for associating CEM with blood coagulation disorders, potentially leading to improved diagnostics and therapeutic monitoring. PMID:26233406

  10. Vibration-free stirling cryocooler for high definition microscopy

    NASA Astrophysics Data System (ADS)

    Riabzev, S. V.; Veprik, A. M.; Vilenchik, H. S.; Pundak, N.; Castiel, E.

    2009-12-01

    The normal operation of high definition Scanning Electronic and Helium Ion microscope tools often relies on maintaining particular components at cryogenic temperatures. This has traditionally been accomplished by using liquid coolants such as liquid Nitrogen. This inherently limits the useful temperature range to above 77 K, produces various operational hazards and typically involves elevated ownership costs, inconvenient logistics and maintenance. Mechanical coolers, over-performing the above traditional method and capable of delivering required (even below 77 K) cooling to the above cooled components, have been well-known elsewhere for many years, but their typical drawbacks, such as high purchasing cost, cooler size, low reliability and high power consumption have so far prevented their wide-spreading. Additional critical drawback is inevitable degradation of imagery performance originated from the wideband vibration export as typical for the operation of the mechanical cooler incorporating numerous movable components. Recent advances in the development of reliable, compact, reasonably priced and dynamically quiet linear cryogenic coolers gave rise to so-called "dry cooling" technologies aimed at eventually replacing the traditional use of outdated liquid Nitrogen cooling facilities. Although much improved these newer cryogenic coolers still produce relatively high vibration export which makes them incompatible with modern high definition microscopy tools. This has motivated further research activity towards developing a vibration free closed-cycle mechanical cryocooler. The authors have successfully adapted the standard low vibration Stirling cryogenic refrigerator (Ricor model K535-LV) delivering 5 W@40 K heat lift for use in vibration-sensitive high definition microscopy. This has been achieved by using passive mechanical counterbalancing of the main portion of the low frequency vibration export in combination with an active feed-forward multi-axes suppression of the residual wideband vibration, thermo-conductive vibration isolation struts and soft vibration mounts. The attainable performance of the resulting vibration free linear Stirling cryocooler (Ricor model K535-ULV) is evaluated through a full-scale experimentation.

  11. Vibration-reducing gloves: transmissibility at the palm of the hand in three orthogonal directions.

    PubMed

    McDowell, Thomas W; Dong, Ren G; Welcome, Daniel E; Xu, Xueyan S; Warren, Christopher

    2013-01-01

    Vibration-reducing (VR) gloves are commonly used as a means to help control exposures to hand-transmitted vibrations generated by powered hand tools. The objective of this study was to characterise the vibration transmissibility spectra and frequency-weighted vibration transmissibility of VR gloves at the palm of the hand in three orthogonal directions. Seven adult males participated in the evaluation of seven glove models using a three-dimensional hand-arm vibration test system. Three levels of hand coupling force were applied in the experiment. This study found that, in general, VR gloves are most effective at reducing vibrations transmitted to the palm along the forearm direction. Gloves that are found to be superior at reducing vibrations in the forearm direction may not be more effective in the other directions when compared with other VR gloves. This casts doubts on the validity of the standardised glove screening test. Practitioner Summary: This study used human subjects to measure three-dimensional vibration transmissibility of vibration-reducing gloves at the palm and identified their vibration attenuation characteristics. This study found the gloves to be most effective at reducing vibrations along the forearm direction. These gloves did not effectively attenuate vibration along the handle axial direction.

  12. Numerous applications of fiber optic evanescent wave Fourier transform infrared (FEW-FTIR) spectroscopy for subsurface structural analysis

    NASA Astrophysics Data System (ADS)

    Afanasyeva, Natalia I.; Welser, Leslie; Bruch, Reinhard F.; Kano, Angelique; Makhine, Volodymyr

    1999-10-01

    A new infrared (IR) interferometric method has been developed in conjunction with low-loss, flexible optical fibers, sensors, and probes. This combination of fiber optical sensors and Fourier Transform (FT) spectrometers can be applied to many fields, including (1) noninvasive medical diagnostics of cancer and other different diseases in vivo, (2) minimally invasive bulk diagnostics of tissue, (3) remote monitoring of tissue, chemical processes, and environment, (4) surface analysis of polymers and other materials, (5) characterization of the quality of food, pharmacological products, cosmetics, paper, and other wood-related products, as well as (6) agricultural, forensic, geological, mining, and archeological field measurements. In particular, our nondestructive, fast, compact, portable, remote and highly sensitive diagnostics tools are very promising for subsurface analysis at the molecular level without sample preparation. For example, this technique is ideal for different types of soft porous foams, rough polymers, and rock surfaces. Such surfaces, as well as living tissue, are very difficult to investigate by traditional FTIR methods. We present here FEW-FTIR spectra of polymers, banana and grapefruit peels, and living tissues detected directly at surfaces. In addition, results on the vibrational spectral analysis of normal and pathological skin tissue in the region of 850 - 4000 cm-1 are discussed.

  13. Computer assisted blast design and assessment tools

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cameron, A.R.; Kleine, T.H.; Forsyth, W.W.

    1995-12-31

    In general the software required by a blast designer includes tools that graphically present blast designs (surface and underground), can analyze a design or predict its result, and can assess blasting results. As computers develop and computer literacy continues to rise the development of and use of such tools will spread. An example of the tools that are becoming available includes: Automatic blast pattern generation and underground ring design; blast design evaluation in terms of explosive distribution and detonation simulation; fragmentation prediction; blast vibration prediction and minimization; blast monitoring for assessment of dynamic performance; vibration measurement, display and signal processing;more » evaluation of blast results in terms of fragmentation; and risk and reliability based blast assessment. The authors have identified a set of criteria that are essential in choosing appropriate software blasting tools.« less

  14. Human discomfort response to noise combined with vertical vibration

    NASA Technical Reports Server (NTRS)

    Leatherwood, J. D.

    1979-01-01

    An experimental investigation was conducted (1) to determine the effects of combined environmental noise and vertical vibration upon human subjective discomfort response, (2) to develop a model for the prediction of passenger discomfort response to the combined environment, and (3) to develop a set of noise-vibration curves for use as criteria in ride quality design. Subjects were exposed to parametric combinations of noise and vibrations through the use of a realistic laboratory simulator. Results indicated that accurate prediction of passenger ride comfort requires knowledge of both the level and frequency content of the noise and vibration components of a ride environment as well as knowledge of the interactive effects of combined noise and vibration. A design tool in the form of an empirical model of passenger discomfort response to combined noise and vertical vibration was developed and illustrated by several computational examples. Finally, a set of noise-vibration criteria curves were generated to illustrate the fundamental design trade-off possible between passenger discomfort and the noise-vibration levels that produce the discomfort.

  15. Space Tools for Servicing, Repairing, and Maintaining Spacecraft

    NASA Technical Reports Server (NTRS)

    Trevino, Robert C.

    2002-01-01

    Just like mechanics and technicians on Earth, astronauts use a variety of manual and portable power tools in space to repair, service, and maintain spacecraft, like the Space Shuttle and the International Space Station (ISS), and other satellites, like the Hubble Space Telescope (HST). Space tools are divided into two main operating categories: Intravehicular Activity (IVA) tools and Extravehicular Activity (EVA) tools. N A tools are used by astronauts inside the pressurized habitable compartments of a spacecraft for routine maintenance, repair, and unexpected tasks. EVA tools are used by space-suited astronauts outside of their pressurized spacecraft in the vacuum of space.

  16. Design, analysis and testing of a new piezoelectric tool actuator for elliptical vibration turning

    NASA Astrophysics Data System (ADS)

    Lin, Jieqiong; Han, Jinguo; Lu, Mingming; Yu, Baojun; Gu, Yan

    2017-08-01

    A new piezoelectric tool actuator (PETA) for elliptical vibration turning has been developed based on a hybrid flexure hinge connection. Two double parallel four-bar linkage mechanisms and two right circular flexure hinges were chosen to guide the motion. The two input displacement directional stiffness were modeled according to the principle of virtual work modeling method and the kinematic analysis was conducted theoretically. Finite element analysis was used to carry out static and dynamic analyses. To evaluate the performance of the developed PETA, off-line experimental tests were carried out to investigate the step responses, motion strokes, resolutions, parasitic motions, and natural frequencies of the PETA along the two input directions. The relationship between input displacement and output displacement, as well as the tool tip’s elliptical trajectory in different phase shifts was analyzed. By using the developed PETA mechanism, micro-dimple patterns were generated as the preliminary application to demonstrate the feasibility and efficiency of PETA for elliptical vibration turning.

  17. Investigation of earth borne vibrations due to highway traffic and/or construction blasting : final report.

    DOT National Transportation Integrated Search

    1986-06-01

    This study was undertaken to determine the magnitude of ground vibrations produced by traffic and/or construction blasting. Such information could provide a tool in defense of legal claims concerning physical damage to nearby properties. An engineeri...

  18. Recent advances in synthetic biology of cyanobacteria.

    PubMed

    Sengupta, Annesha; Pakrasi, Himadri B; Wangikar, Pramod P

    2018-05-09

    Cyanobacteria are attractive hosts that can be engineered for the photosynthetic production of fuels, fine chemicals, and proteins from CO 2 . Moreover, the responsiveness of these photoautotrophs towards different environmental signals, such as light, CO 2 , diurnal cycle, and metals make them potential hosts for the development of biosensors. However, engineering these hosts proves to be a challenging and lengthy process. Synthetic biology can make the process of biological engineering more predictable through the use of standardized biological parts that are well characterized and tools to assemble them. While significant progress has been made with model heterotrophic organisms, many of the parts and tools are not portable in cyanobacteria. Therefore, efforts are underway to develop and characterize parts derived from cyanobacteria. In this review, we discuss the reported parts and tools with the objective to develop cyanobacteria as cell factories or biosensors. We also discuss the issues related to characterization, tunability, portability, and the need to develop enabling technologies to engineer this "green" chassis.

  19. Instant detection and identification of concealed explosive-related compounds: Induced Stokes Raman versus infrared.

    PubMed

    Elbasuney, Sherif; El-Sherif, Ashraf F

    2017-01-01

    The instant detection of explosives and explosive-related compounds has become an urgent priority in recent years for homeland security and counter-terrorism applications. Modern techniques should offer enhancement in selectivity, sensitivity, and standoff distances. Miniaturisation, portability, and field-ruggedisation are crucial requirements. This study reports on instant and standoff identification of concealed explosive-related compounds using customized Raman technique. Stokes Raman spectra of common explosive-related compounds were generated and spectrally resolved to create characteristic finger print spectra. The scattered Raman emissions over the band 400:2000cm -1 were compared to infrared absorption using FTIR. It has been demonstrated that the two vibrational spectroscopic techniques were opposite and completing each other. Molecular vibrations with strong absorption in infrared (those involve strong change in dipole moments) induced weak signals in Raman and vice versa. The tailored Raman offered instant detection, high sensitivity, and standoff detection capabilities. Raman demonstrated characteristic fingerprint spectra with stable baseline and sharp intense peaks. Complete correlations of absorption/scattered signals to certain molecular vibrations were conducted to generate an entire spectroscopic profile of explosive-related compounds. This manuscript shades the light on Raman as one of the prevailing technologies for instantaneous detection of explosive-related compounds. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Portable infrared pupillometry: a review.

    PubMed

    Larson, Merlin D; Behrends, Matthias

    2015-06-01

    Portable infrared pupillometers provide an objective measure of pupil size and pupillary reflexes, which for most clinicians was previously only a visual impression. But despite the fact that pupillometry can uncover aspects of how the human pupil reacts to drugs and noxious stimulation, the use of pupillometry has not gained widespread use among anesthesiologists and critical care physicians. The present review is an introduction to the physiology of pupillary reflexes and the currently established clinical applications of infrared pupillometry, which will hopefully encourage physicians to use this diagnostic tool in their clinical practice. Portable infrared pupillometry was introduced in 1989. The technology involves flooding the eye with infrared light and then measuring the reflected image on an infrared sensor. Pupil size, along with variables of the pupillary light reflex and pupillary reflex dilation, is calculated by the instrument and displayed on a screen immediately after each time-stamped measurement. Use of these instruments has uncovered aspects of how the human pupil reacts to drugs and noxious stimulation. The primary clinical applications for portable pupillometry have been in the assessment of brainstem function. Portable pupillometry is useful in the management of pain because it allows for assessments of the effect of opioids and in the titration of combined regional-general anesthetics.

  1. Measurement of protein-like fluorescence in river and waste water using a handheld spectrophotometer.

    PubMed

    Baker, Andy; Ward, David; Lieten, Shakti H; Periera, Ryan; Simpson, Ellie C; Slater, Malcolm

    2004-07-01

    Protein-like fluorescence intensity in rivers increases with increasing anthropogenic DOM inputs from sewerage and farm wastes. Here, a portable luminescence spectrophotometer was used to investigate if this technology could be used to provide both field scientists with a rapid pollution monitoring tool and process control engineers with a portable waste water monitoring device, through the measurement of river and waste water tryptophan-like fluorescence from a range of rivers in NE England and from effluents from within two waste water treatment plants. The portable spectrophotometer determined that waste waters and sewerage effluents had the highest tryptophan-like fluorescence intensity, urban streams had an intermediate tryptophan-like fluorescence intensity, and the upstream river samples of good water quality the lowest tryptophan-like fluorescence intensity. Replicate samples demonstrated that fluorescence intensity is reproducible to +/- 20% for low fluorescence, 'clean' river water samples and +/- 5% for urban water and waste waters. Correlations between fluorescence measured by the portable spectrophotometer with a conventional bench machine were 0.91; (Spearman's rho, n = 143), demonstrating that the portable spectrophotometer does correlate with tryptophan-like fluorescence intensity measured using the bench spectrophotometer.

  2. 33 CFR 142.84 - Housekeeping.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... be kept clear of portable tools, materials, and equipment not in use and be promptly cleared of..., footwear and flooring designed to reduce slipping substantially may be used instead of keeping the drill...

  3. 33 CFR 142.84 - Housekeeping.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... be kept clear of portable tools, materials, and equipment not in use and be promptly cleared of..., footwear and flooring designed to reduce slipping substantially may be used instead of keeping the drill...

  4. 33 CFR 142.84 - Housekeeping.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... be kept clear of portable tools, materials, and equipment not in use and be promptly cleared of..., footwear and flooring designed to reduce slipping substantially may be used instead of keeping the drill...

  5. 33 CFR 142.84 - Housekeeping.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... be kept clear of portable tools, materials, and equipment not in use and be promptly cleared of..., footwear and flooring designed to reduce slipping substantially may be used instead of keeping the drill...

  6. 33 CFR 142.84 - Housekeeping.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... be kept clear of portable tools, materials, and equipment not in use and be promptly cleared of..., footwear and flooring designed to reduce slipping substantially may be used instead of keeping the drill...

  7. Code generator for implementing dual tree complex wavelet transform on reconfigurable architectures for mobile applications

    PubMed Central

    Canbay, Ferhat; Levent, Vecdi Emre; Serbes, Gorkem; Ugurdag, H. Fatih; Goren, Sezer

    2016-01-01

    The authors aimed to develop an application for producing different architectures to implement dual tree complex wavelet transform (DTCWT) having near shift-invariance property. To obtain a low-cost and portable solution for implementing the DTCWT in multi-channel real-time applications, various embedded-system approaches are realised. For comparison, the DTCWT was implemented in C language on a personal computer and on a PIC microcontroller. However, in the former approach portability and in the latter desired speed performance properties cannot be achieved. Hence, implementation of the DTCWT on a reconfigurable platform such as field programmable gate array, which provides portable, low-cost, low-power, and high-performance computing, is considered as the most feasible solution. At first, they used the system generator DSP design tool of Xilinx for algorithm design. However, the design implemented by using such tools is not optimised in terms of area and power. To overcome all these drawbacks mentioned above, they implemented the DTCWT algorithm by using Verilog Hardware Description Language, which has its own difficulties. To overcome these difficulties, simplify the usage of proposed algorithms and the adaptation procedures, a code generator program that can produce different architectures is proposed. PMID:27733925

  8. Code generator for implementing dual tree complex wavelet transform on reconfigurable architectures for mobile applications.

    PubMed

    Canbay, Ferhat; Levent, Vecdi Emre; Serbes, Gorkem; Ugurdag, H Fatih; Goren, Sezer; Aydin, Nizamettin

    2016-09-01

    The authors aimed to develop an application for producing different architectures to implement dual tree complex wavelet transform (DTCWT) having near shift-invariance property. To obtain a low-cost and portable solution for implementing the DTCWT in multi-channel real-time applications, various embedded-system approaches are realised. For comparison, the DTCWT was implemented in C language on a personal computer and on a PIC microcontroller. However, in the former approach portability and in the latter desired speed performance properties cannot be achieved. Hence, implementation of the DTCWT on a reconfigurable platform such as field programmable gate array, which provides portable, low-cost, low-power, and high-performance computing, is considered as the most feasible solution. At first, they used the system generator DSP design tool of Xilinx for algorithm design. However, the design implemented by using such tools is not optimised in terms of area and power. To overcome all these drawbacks mentioned above, they implemented the DTCWT algorithm by using Verilog Hardware Description Language, which has its own difficulties. To overcome these difficulties, simplify the usage of proposed algorithms and the adaptation procedures, a code generator program that can produce different architectures is proposed.

  9. SSRL Emergency Response Shore Tool

    NASA Technical Reports Server (NTRS)

    Mah, Robert W.; Papasin, Richard; McIntosh, Dawn M.; Denham, Douglas; Jorgensen, Charles; Betts, Bradley J.; Del Mundo, Rommel

    2006-01-01

    The SSRL Emergency Response Shore Tool (wherein SSRL signifies Smart Systems Research Laboratory ) is a computer program within a system of communication and mobile-computing software and hardware being developed to increase the situational awareness of first responders at building collapses. This program is intended for use mainly in planning and constructing shores to stabilize partially collapsed structures. The program consists of client and server components, runs in the Windows operating system on commercial off-the-shelf portable computers, and can utilize such additional hardware as digital cameras and Global Positioning System devices. A first responder can enter directly, into a portable computer running this program, the dimensions of a required shore. The shore dimensions, plus an optional digital photograph of the shore site, can then be uploaded via a wireless network to a server. Once on the server, the shore report is time-stamped and made available on similarly equipped portable computers carried by other first responders, including shore wood cutters and an incident commander. The staff in a command center can use the shore reports and photographs to monitor progress and to consult with structural engineers to assess whether a building is in imminent danger of further collapse.

  10. Stating the Obvious: The European Qualifications Framework is "Not" a Neutral Evidence-Based Policy Tool

    ERIC Educational Resources Information Center

    Cort, Pia

    2010-01-01

    In European Union policy documents, the European Qualifications Framework (EQF) is described as a neutral tool embedded in an evidence-based policy process. Its purpose is to improve the transparency, comparability and portability of qualifications in the European Union. The aim of this article is to denaturalise the EQF discourse through a…

  11. UNIX as an environment for producing numerical software

    NASA Technical Reports Server (NTRS)

    Schryer, N. L.

    1978-01-01

    The UNIX operating system supports a number of software tools; a mathematical equation-setting language, a phototypesetting language, a FORTRAN preprocessor language, a text editor, and a command interpreter. The design, implementation, documentation, and maintenance of a portable FORTRAN test of the floating-point arithmetic unit of a computer is used to illustrate these tools at work.

  12. Analysis of Java Client/Server and Web Programming Tools for Development of Educational Systems.

    ERIC Educational Resources Information Center

    Muldner, Tomasz

    This paper provides an analysis of old and new programming tools for development of client/server programs, particularly World Wide Web-based programs. The focus is on development of educational systems that use interactive shared workspaces to provide portable and expandable solutions. The paper begins with a short description of relevant terms.…

  13. Portable computing - A fielded interactive scientific application in a small off-the-shelf package

    NASA Technical Reports Server (NTRS)

    Groleau, Nicolas; Hazelton, Lyman; Frainier, Rich; Compton, Michael; Colombano, Silvano; Szolovits, Peter

    1993-01-01

    Experience with the design and implementation of a portable computing system for STS crew-conducted science is discussed. Principal-Investigator-in-a-Box (PI) will help the SLS-2 astronauts perform vestibular (human orientation system) experiments in flight. PI is an interactive system that provides data acquisition and analysis, experiment step rescheduling, and various other forms of reasoning to astronaut users. The hardware architecture of PI consists of a computer and an analog interface box. 'Off-the-shelf' equipment is employed in the system wherever possible in an effort to use widely available tools and then to add custom functionality and application codes to them. Other projects which can help prospective teams to learn more about portable computing in space are also discussed.

  14. A portable high-speed camera system for vocal fold examinations.

    PubMed

    Hertegård, Stellan; Larsson, Hans

    2014-11-01

    In this article, we present a new portable low-cost system for high-speed examinations of the vocal folds. Analysis of glottal vibratory parameters from the high-speed recordings is compared with videostroboscopic recordings. The high-speed system is built around a Fastec 1 monochrome camera, which is used with newly developed software, High-Speed Studio (HSS). The HSS has options for video/image recording, contains a database, and has a set of analysis options. The Fastec/HSS system has been used clinically since 2011 in more than 2000 patient examinations and recordings. The Fastec 1 camera has sufficient time resolution (≥4000 frames/s) and light sensitivity (ISO 3200) to produce images for detailed analyses of parameters pertinent to vocal fold function. The camera can be used with both rigid and flexible endoscopes. The HSS software includes options for analyses of glottal vibrations, such as kymogram, phase asymmetry, glottal area variation, open and closed phase, and angle of vocal fold abduction. It can also be used for separate analysis of the left and vocal fold movements, including maximum speed during opening and closing, a parameter possibly related to vocal fold elasticity. A blinded analysis of 32 patients with various voice disorders examined with both the Fastec/HSS system and videostroboscopy showed that the high-speed recordings were significantly better for the analysis of glottal parameters (eg, mucosal wave and vibration asymmetry). The monochrome high-speed system can be used in daily clinical work within normal clinical time limits for patient examinations. A detailed analysis can be made of voice disorders and laryngeal pathology at a relatively low cost. Copyright © 2014 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  15. 29 CFR 1910.212 - General requirements for all machines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Alligator shears. (d) Power presses. (e) Milling machines. (f) Power saws. (g) Jointers. (h) Portable power tools. (i) Forming rolls and calenders. (4) Barrels, containers, and drums. Revolving drums, barrels...

  16. Portable Holographic Interferometry Testing System: Application to crack patching quality control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heslehurst, R.B.; Baird, J.P.; Williamson, H.M.

    Over recent years the repair of metallic structures has been improved through the use of patches fabricated from composite materials and adhesively bonded to the damaged area. This technology is termed crack patching, and has been successfully and extensively used by the RAAF and the USAF. However, application of the technology to civilian registered aircraft has had limited success due to the apparent lack of suitable quality assurance testing methods and the airworthiness regulators concern overpatch adhesion integrity. Holographic interferometry has previously shown the advantages of detecting out-of-plane deformations of the order of the wavelength of light (1{mu}). Evidence willmore » be presented that holography is able to detect changes in load path due to debonds and weakened adhesion in an adhesively bonded patch. A Portable Holographic Interferometry Testing System (PHITS) which overcomes the vibration isolation problem associated with conventional holography techniques has been developed. The application of PHITS to crack patching technology now provides a suitable method to verify the integrity of bonded patches in-situ.« less

  17. Rapid cable tension estimation using dynamic and mechanical properties

    NASA Astrophysics Data System (ADS)

    Martínez-Castro, Rosana E.; Jang, Shinae; Christenson, Richard E.

    2016-04-01

    Main tension elements are critical to the overall stability of cable-supported bridges. A dependable and rapid determination of cable tension is desired to assess the state of a cable-supported bridge and evaluate its operability. A portable smart sensor setup is presented to reduce post-processing time and deployment complexity while reliably determining cable tension using dynamic characteristics extracted from spectral analysis. A self-recording accelerometer is coupled with a single-board microcomputer that communicates wirelessly with a remote host computer. The portable smart sensing device is designed such that additional algorithms, sensors and controlling devices for various monitoring applications can be installed and operated for additional structural assessment. The tension-estimating algorithms are based on taut string theory and expand to consider bending stiffness. The successful combination of cable properties allows the use of a cable's dynamic behavior to determine tension force. The tension-estimating algorithms are experimentally validated on a through-arch steel bridge subject to ambient vibration induced by passing traffic. The tension estimation is determined in well agreement with previously determined tension values for the structure.

  18. A longitudinal study of vibration white finger, cold response of digital arteries, and measures of daily vibration exposure.

    PubMed

    Bovenzi, Massimo

    2010-03-01

    To investigate prospectively the relation between vibration-induced vascular disorders and measures of daily exposure to hand-transmitted vibration (HTV). Two hundred and forty-nine HTV workers and 138 control men of the same companies participated in a 3-year follow-up study. The diagnosis of vibration induced white finger (VWF) in the HTV workers and that of Raynaud's phenomenon in the controls was based on the medical history, the administration of color charts and the results of a cold test with measurement of finger systolic blood pressures. Vibration magnitudes from the tools were measured as r.m.s acceleration, frequency weighted according to international standard ISO 5349-1, and also unweighted over the frequency range 6.3-1,250 Hz. Daily vibration exposure was expressed in terms of daily exposure duration and frequency-weighted or unweighted r.m.s. acceleration normalized to a reference period of 8 h (Aw(8) or Auw(8), respectively). The incidence of VWF varied from 5 to 6% in the HTV workers versus 0-1.5% for Raynaud's phenomenon in the controls. After adjusting for potential confounders, Auw(8) gave better predictions of the incidence of VWF and the cold response of the digital arteries over time than Aw(8) or daily exposure duration. These findings were observed in the entire sample of HTV workers, in those with no VWF at the initial investigation, and in those with normal cold test results at baseline. The findings of this longitudinal study suggest that a measure of daily vibration exposure calculated from unweighted r.m.s. acceleration over the frequency range 6.3-1,250 Hz performs better for the prediction of vascular disorders in users of vibratory tools than a measure derived from r.m.s. acceleration frequency weighted according to ISO 5349-1. This study provides epidemiological evidence that more weight should be given to intermediate and high-frequency vibration for evaluating the severity of hand-transmitted vibration.

  19. The Shock and Vibration Digest. Volume 15, Number 9

    DTIC Science & Technology

    1983-09-01

    of Exciting Energy Supply E. Marui , S. Ema, and S. Kato Gifu Univ., 1-1 Yanagido, Gifu-shi, 501-11, Japan, J. Engrg. Indus., Trans. ASME, 105 (2), pp...Vibration of Lathe Tools. Part 1: General Modal Methods in Continuous Bridge Deck Statics * Characteristics of Chatter Vibration A.G. Zechini E. Marui , S...1758 Pombo, J.L ............. 1901 Kato, S........... 1711, 1712 Mark, W.D.............. 1702 Popov, M.M.. 1859 * Kaufman, A ............. 1769 Marui , E

  20. Automated Portable Test System (APTS) - A performance envelope assessment tool

    NASA Technical Reports Server (NTRS)

    Kennedy, R. S.; Dunlap, W. P.; Jones, M. B.; Wilkes, R. L.; Bittner, A. C., Jr.

    1985-01-01

    The reliability and stability of microcomputer-based psychological tests are evaluated. The hardware, test programs, and system control of the Automated Portable Test System, which assesses human performance and subjective status, are described. Subjects were administered 11 pen-and-pencil and microcomputer-based tests for 10 sessions. The data reveal that nine of the 10 tests stabilized by the third administration; inertial correlations were high and consistent. It is noted that the microcomputer-based tests display good psychometric properties in terms of differential stability and reliability.

  1. The UNIX Operating System: A Model for Software Design.

    ERIC Educational Resources Information Center

    Kernighan, Brian W.; Morgan, Samuel P.

    1982-01-01

    Describes UNIX time-sharing operating system, including the program environment, software development tools, flexibility and ease of change, portability and other advantages, and five applications and three nonapplications of the system. (JN)

  2. MindSeer: a portable and extensible tool for visualization of structural and functional neuroimaging data

    PubMed Central

    Moore, Eider B; Poliakov, Andrew V; Lincoln, Peter; Brinkley, James F

    2007-01-01

    Background Three-dimensional (3-D) visualization of multimodality neuroimaging data provides a powerful technique for viewing the relationship between structure and function. A number of applications are available that include some aspect of 3-D visualization, including both free and commercial products. These applications range from highly specific programs for a single modality, to general purpose toolkits that include many image processing functions in addition to visualization. However, few if any of these combine both stand-alone and remote multi-modality visualization in an open source, portable and extensible tool that is easy to install and use, yet can be included as a component of a larger information system. Results We have developed a new open source multimodality 3-D visualization application, called MindSeer, that has these features: integrated and interactive 3-D volume and surface visualization, Java and Java3D for true cross-platform portability, one-click installation and startup, integrated data management to help organize large studies, extensibility through plugins, transparent remote visualization, and the ability to be integrated into larger information management systems. We describe the design and implementation of the system, as well as several case studies that demonstrate its utility. These case studies are available as tutorials or demos on the associated website: . Conclusion MindSeer provides a powerful visualization tool for multimodality neuroimaging data. Its architecture and unique features also allow it to be extended into other visualization domains within biomedicine. PMID:17937818

  3. MindSeer: a portable and extensible tool for visualization of structural and functional neuroimaging data.

    PubMed

    Moore, Eider B; Poliakov, Andrew V; Lincoln, Peter; Brinkley, James F

    2007-10-15

    Three-dimensional (3-D) visualization of multimodality neuroimaging data provides a powerful technique for viewing the relationship between structure and function. A number of applications are available that include some aspect of 3-D visualization, including both free and commercial products. These applications range from highly specific programs for a single modality, to general purpose toolkits that include many image processing functions in addition to visualization. However, few if any of these combine both stand-alone and remote multi-modality visualization in an open source, portable and extensible tool that is easy to install and use, yet can be included as a component of a larger information system. We have developed a new open source multimodality 3-D visualization application, called MindSeer, that has these features: integrated and interactive 3-D volume and surface visualization, Java and Java3D for true cross-platform portability, one-click installation and startup, integrated data management to help organize large studies, extensibility through plugins, transparent remote visualization, and the ability to be integrated into larger information management systems. We describe the design and implementation of the system, as well as several case studies that demonstrate its utility. These case studies are available as tutorials or demos on the associated website: http://sig.biostr.washington.edu/projects/MindSeer. MindSeer provides a powerful visualization tool for multimodality neuroimaging data. Its architecture and unique features also allow it to be extended into other visualization domains within biomedicine.

  4. Vibration-reducing gloves: transmissibility at the palm of the hand in three orthogonal directions

    PubMed Central

    McDowell, Thomas W.; Dong, Ren G.; Welcome, Daniel E.; Xu, Xueyan S.; Warren, Christopher

    2015-01-01

    Vibration-reducing (VR) gloves are commonly used as a means to help control exposures to hand-transmitted vibrations generated by powered hand tools. The objective of this study was to characterise the vibration transmissibility spectra and frequency-weighted vibration transmissibility of VR gloves at the palm of the hand in three orthogonal directions. Seven adult males participated in the evaluation of seven glove models using a three-dimensional hand–arm vibration test system. Three levels of hand coupling force were applied in the experiment. This study found that, in general, VR gloves are most effective at reducing vibrations transmitted to the palm along the forearm direction. Gloves that are found to be superior at reducing vibrations in the forearm direction may not be more effective in the other directions when compared with other VR gloves. This casts doubts on the validity of the standardised glove screening test. Practitioner Summary This study used human subjects to measure three-dimensional vibration transmissibility of vibration-reducing gloves at the palm and identified their vibration attenuation characteristics. This study found the gloves to be most effective at reducing vibrations along the forearm direction. These gloves did not effectively attenuate vibration along the handle axial direction. PMID:24160755

  5. Comparison of Numerical Modeling Methods for Soil Vibration Cutting

    NASA Astrophysics Data System (ADS)

    Jiang, Jiandong; Zhang, Enguang

    2018-01-01

    In this paper, we studied the appropriate numerical simulation method for vibration soil cutting. Three numerical simulation methods, commonly used for uniform speed soil cutting, Lagrange, ALE and DEM, are analyzed. Three models of vibration soil cutting simulation model are established by using ls-dyna.The applicability of the three methods to this problem is analyzed in combination with the model mechanism and simulation results. Both the Lagrange method and the DEM method can show the force oscillation of the tool and the large deformation of the soil in the vibration cutting. Lagrange method shows better effect of soil debris breaking. Because of the poor stability of ALE method, it is not suitable to use soil vibration cutting problem.

  6. Process Damping and Cutting Tool Geometry in Machining

    NASA Astrophysics Data System (ADS)

    Taylor, C. M.; Sims, N. D.; Turner, S.

    2011-12-01

    Regenerative vibration, or chatter, limits the performance of machining processes. Consequences of chatter include tool wear and poor machined surface finish. Process damping by tool-workpiece contact can reduce chatter effects and improve productivity. Process damping occurs when the flank (also known as the relief face) of the cutting tool makes contact with waves on the workpiece surface, created by chatter motion. Tool edge features can act to increase the damping effect. This paper examines how a tool's edge condition combines with the relief angle to affect process damping. An analytical model of cutting with chatter leads to a two-section curve describing how process damped vibration amplitude changes with surface speed for radiussed tools. The tool edge dominates the process damping effect at the lowest surface speeds, with the flank dominating at higher speeds. A similar curve is then proposed regarding tools with worn edges. Experimental data supports the notion of the two-section curve. A rule of thumb is proposed which could be useful to machine operators, regarding tool wear and process damping. The question is addressed, should a tool of a given geometry, used for a given application, be considered as sharp, radiussed or worn regarding process damping.

  7. Comparison of the Wii Balance Board and the BESS tool measuring postural stability in collegiate athletes.

    PubMed

    Guzman, Jill; Aktan, Nadine

    2016-02-01

    Concussions are a major health concern for athletes given the potential for these injuries in a wide range of sport activities. The leading concern for clinicians is that athletes are at risk for devastating consequences if they are not evaluated properly and cleared too early to return to play or competition. The evaluation of postural stability has been identified as an important aspect to the comprehensive management of such injuries. Clinicians are in need of a portable tool they can use in various settings to aid in decision making and health care delivery for concussed athletes. The Nintendo Wii Balance Board (Nintendo of America Inc., Redmond, Washington) is a portable, cost-effective tool that has the potential to aid in the evaluation of postural stability in concussed individuals. The purpose of this study was to evaluate the Wii Balance Board as an objective, user-friendly, cost effective, valid alternative tool for the measurement of postural stability in college athletes. This study questioned whether the Wii Balance Board, when compared to the Balance Error Scoring System (BESS), is an objective tool that can be used as an acceptable measurement of postural stability in college athletes. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. XS: a FASTQ read simulator.

    PubMed

    Pratas, Diogo; Pinho, Armando J; Rodrigues, João M O S

    2014-01-16

    The emerging next-generation sequencing (NGS) is bringing, besides the natural huge amounts of data, an avalanche of new specialized tools (for analysis, compression, alignment, among others) and large public and private network infrastructures. Therefore, a direct necessity of specific simulation tools for testing and benchmarking is rising, such as a flexible and portable FASTQ read simulator, without the need of a reference sequence, yet correctly prepared for producing approximately the same characteristics as real data. We present XS, a skilled FASTQ read simulation tool, flexible, portable (does not need a reference sequence) and tunable in terms of sequence complexity. It has several running modes, depending on the time and memory available, and is aimed at testing computing infrastructures, namely cloud computing of large-scale projects, and testing FASTQ compression algorithms. Moreover, XS offers the possibility of simulating the three main FASTQ components individually (headers, DNA sequences and quality-scores). XS provides an efficient and convenient method for fast simulation of FASTQ files, such as those from Ion Torrent (currently uncovered by other simulators), Roche-454, Illumina and ABI-SOLiD sequencing machines. This tool is publicly available at http://bioinformatics.ua.pt/software/xs/.

  9. Analysis of stationary displacement patterns in rotating machinery subject to local harmonic excitation

    NASA Astrophysics Data System (ADS)

    Österlind, Tomas; Kari, Leif; Nicolescu, Cornel Mihai

    2017-02-01

    Rotor vibration and stationary displacement patterns observed in rotating machineries subject to local harmonic excitation are analysed for improved understanding and dynamic characterization. The analysis stresses the importance of coordinate transformation between rotating and stationary frame of reference for accurate results and estimation of dynamic properties. A generic method which can be used for various rotor applications such as machine tool spindle and turbo machinery vibration is presented. The phenomenon shares similarities with stationary waves in rotating disks though focuses on vibration in shafts. The paper further proposes a graphical tool, the displacement map, which can be used for selection of stable rotational speed for rotating machinery. The results are validated through simulation of dynamic response of a milling cutter, which is a typical example of a variable speed rotor operating under different load conditions.

  10. Transmission Bearing Damage Detection Using Decision Fusion Analysis

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Lewicki, David G.; Decker, Harry J.

    2004-01-01

    A diagnostic tool was developed for detecting fatigue damage to rolling element bearings in an OH-58 main rotor transmission. Two different monitoring technologies, oil debris analysis and vibration, were integrated using data fusion into a health monitoring system for detecting bearing surface fatigue pitting damage. This integrated system showed improved detection and decision-making capabilities as compared to using individual monitoring technologies. This diagnostic tool was evaluated by collecting vibration and oil debris data from tests performed in the NASA Glenn 500 hp Helicopter Transmission Test Stand. Data was collected during experiments performed in this test rig when two unanticipated bearing failures occurred. Results show that combining the vibration and oil debris measurement technologies improves the detection of pitting damage on spiral bevel gears duplex ball bearings and spiral bevel pinion triplex ball bearings in a main rotor transmission.

  11. Mission Implementation Constraints on Planetary Muon Radiography

    NASA Technical Reports Server (NTRS)

    Jones, Cathleen E.; Kedar, Sharon; Naudet, Charles; Webb, Frank

    2011-01-01

    Cost: Use heritage hardware, especially use a tested landing system to reduce cost (Phoenix or MSL EDL stage). The sky crane technology delivers higher mass to the surface and enables reaching targets at higher elevation, but at a higher mission cost. Rover vs. Stationary Lander: Rover-mounted instrument enables tomography, but the increased weight of the rover reduces the allowable payload weight. Mass is the critical design constraint for an instrument for a planetary mission. Many factors that are minor factors or do not enter into design considerations for terrestrial operation are important for a planetary application. (Landing site, diurnal temperature variation, instrument portability, shock/vibration)

  12. Subjective scaling of hand-arm vibration.

    PubMed

    Maeda, Setsuo; Shibata, Nobuyuki

    2008-04-01

    The purpose of this research was to establish a scale for comfort with regard to hand-arm vibration using the category judgment method and to validate the frequency-weighting method of the ISO 5349-1 standard. Experiments were conducted using random signals as stimuli. These stimuli consisted of three types of signal, namely designated stimulus F, with flat power spectrum density (PSD) ranging from 1 to 1,000 Hz, stimulus H with PSD which became 20 dB higher at 1,000 Hz than at 1 Hz, and stimulus L that had a PSD 20 dB lower at 1,000 Hz. These stimuli were selected from the specific spectrum patterns of hand-held vibration tools. These signals were modified by the Wh frequency weighting in accordance with ISO 5349-1, and the R.M.S. values were adjusted to be equal. In addition, the signal levels were varied over a range of five steps to create 15 kinds of individual stimuli. The subjects sat in front of a vibrator and grasped the mounted handle which exposed them to vertical vibrations after which they were asked to choose a numerical category to best indicate their perceived level of comfort (or otherwise) during each stimulus. From the experimental results of the category judgment method, the relationship between the psychological values and the frequency-weighted R.M.S. acceleration according to the ISO 5349-1 standard was obtained. It was found that the subjective response scaling of hand-arm vibration can be used for design-objective values of hand-held tool vibration.

  13. 29 CFR 1910.244 - Other portable tools and equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... casting, stamping, or other suitable means. (2) Operation and maintenance. (i) In the absence of a firm... examined for possible defects. (viii) Jacks which are out of order shall be tagged accordingly, and shall...

  14. 29 CFR 1910.244 - Other portable tools and equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... casting, stamping, or other suitable means. (2) Operation and maintenance. (i) In the absence of a firm... examined for possible defects. (viii) Jacks which are out of order shall be tagged accordingly, and shall...

  15. 29 CFR 1910.244 - Other portable tools and equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... casting, stamping, or other suitable means. (2) Operation and maintenance. (i) In the absence of a firm... examined for possible defects. (viii) Jacks which are out of order shall be tagged accordingly, and shall...

  16. 29 CFR 1910.244 - Other portable tools and equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... casting, stamping, or other suitable means. (2) Operation and maintenance. (i) In the absence of a firm... examined for possible defects. (viii) Jacks which are out of order shall be tagged accordingly, and shall...

  17. 29 CFR 1910.244 - Other portable tools and equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... casting, stamping, or other suitable means. (2) Operation and maintenance. (i) In the absence of a firm... examined for possible defects. (viii) Jacks which are out of order shall be tagged accordingly, and shall...

  18. Vibration on board and health effects.

    PubMed

    Jensen, Anker; Jepsen, Jørgen Riis

    2014-01-01

    There is only limited knowledge of the exposure to vibrations of ships' crews and their risk of vibration-induced health effects. Exposure to hand-arm vibrations from the use of vibrating tools at sea does not differ from that in the land-based trades. However, in contrast to most other work places, seafarers are also exposed to vibrations to the feet when standing on vibrating surfaces on board. Anecdotal reports have related the development of "white feet" to local exposure to vibration, e.g. in mining, but this connection has not been investigated in the maritime setting. As known from studies of the health consequences of whole body vibrations in land-transportation, such exposure at sea may affect ships' passengers and crews. While the relation of back disorders to high levels of whole body vibration has been demonstrated among e.g. tractor drivers, there are no reported epidemiological evidence for such relation among seafarers except for fishermen, who, however, are also exposed to additional recognised physical risk factors at work. The assessment and reduction of vibrations by naval architects relates to technical implications of this impact for the ships' construction, but has limited value for the estimation of health risks because they express the vibration intensity differently that it is done in a medical context.

  19. The control of flexible structure vibrations using a cantilevered adaptive truss

    NASA Technical Reports Server (NTRS)

    Wynn, Robert H., Jr.; Robertshaw, Harry H.

    1991-01-01

    Analytical and experimental procedures and design tools are presented for the control of flexible structure vibrations using a cantilevered adaptive truss. Simulated and experimental data are examined for three types of structures: a slender beam, a single curved beam, and two curved beams. The adaptive truss is shown to produce a 6,000-percent increase in damping, demonstrating its potential in vibration control. Good agreement is obtained between the simulated and experimental data, thus validating the modeling methods.

  20. Design selection of an innovative tool holder for ultrasonic vibration assisted turning (IN-UVAT) using finite element analysis simulation

    NASA Astrophysics Data System (ADS)

    Rachmat, Haris; Ibrahim, M. Rasidi; Hasan, Sulaiman bin

    2017-04-01

    On of high technology in machining is ultrasonic vibration assisted turning. The design of tool holder was a crucial step to make sure the tool holder is enough to handle all forces on turning process. Because of the direct experimental approach is expensive, the paper studied to predict feasibility of tool holder displacement and effective stress was used the computational in finite element simulation. SS201 and AISI 1045 materials were used with sharp and ramp corners flexure hinges on design. The result shows that AISI 1045 material and which has ramp corner flexure hinge was the best choice to be produced. The displacement is around 11.3 micron and effective stress is 1.71e+008 N/m2 and also the factor of safety is 3.10.

  1. Hand-arm vibration syndrome: A rarely seen diagnosis.

    PubMed

    Campbell, Rebecca A; Janko, Matthew R; Hacker, Robert I

    2017-06-01

    Hand-arm vibration syndrome (HAVS) is a collection of sensory, vascular, and musculoskeletal symptoms caused by repetitive trauma from vibration. This case report demonstrates how to diagnose HAVS on the basis of history, physical examination, and vascular imaging and its treatment options. A 41-year-old man who regularly used vibrating tools presented with nonhealing wounds on his right thumb and third digit. Arteriography revealed occlusions of multiple arteries in his hand with formation of collaterals. We diagnosed HAVS, and his wounds healed after several weeks with appropriate treatment. HAVS is a debilitating condition with often irreversible vascular damage, requiring early diagnosis and treatment.

  2. Performance Analysis and Portability of the PLUM Load Balancing System

    NASA Technical Reports Server (NTRS)

    Oliker, Leonid; Biswas, Rupak; Gabow, Harold N.

    1998-01-01

    The ability to dynamically adapt an unstructured mesh is a powerful tool for solving computational problems with evolving physical features; however, an efficient parallel implementation is rather difficult. To address this problem, we have developed PLUM, an automatic portable framework for performing adaptive numerical computations in a message-passing environment. PLUM requires that all data be globally redistributed after each mesh adaption to achieve load balance. We present an algorithm for minimizing this remapping overhead by guaranteeing an optimal processor reassignment. We also show that the data redistribution cost can be significantly reduced by applying our heuristic processor reassignment algorithm to the default mapping of the parallel partitioner. Portability is examined by comparing performance on a SP2, an Origin2000, and a T3E. Results show that PLUM can be successfully ported to different platforms without any code modifications.

  3. Phonon thermodynamics of iron and cementite

    NASA Astrophysics Data System (ADS)

    Mauger, Lisa Mary

    The vibrational properties of materials are essential to understanding material stability and thermodynamics. In this thesis I outline vibrational thermodynamic models and the experimental tools that provide evidence on phonon behavior. The introductory section discusses the history of metallurgy and thermodynamic theory, with an emphasis on the role of iron and cementite, two important components of steels. The thermodynamic framework for understanding vibrational material behavior is provided alongside the growing body of experimental and computational tools that provide physical insight on vibrational properties. The high temperature vibrational behavior of iron and cementite are explored within this context in the final chapters. Body-centered-cubic iron exhibits decreasing phonon energies at elevated temperatures. The observed energy change in not uniform across phonon modes in iron, and specific phonon modes show significant decreases in energy that are not explained by simple vibrational models. This anomalously energy decrease is linked to the second-nearest-neighbor interactions in the bcc structure, through examination of fitted interatomic force constants. The large changes in phonon energy result in a significant increase in the vibrational entropy, called the nonharmonic vibrational entropy, which emulates the temperature behavior of the magnetic entropy across the Curie temperature. The nonharmonic vibrational entropy is attributed to interactions between the vibrations and state of magnetic disorder in the material, which persists above the magnetic transitions and extends the stability region of the bcc phase. Orthorombic cementite, Fe3C, exhibits anisotropic magneto-volume behavior in the ferromagnetic phase including regions very low thermal expansion. The phonon modes of cementite show anomalous temperature dependence, with low energy phonon modes increasing their energy at elevated temperatures in the ferromagnetic phase. This behavior is reversed after the magnetic transition and these same phonon modes lower their energies with temperature, consistent with observed thermal expansion. This atypical phonon behavior lowers the vibrational entropy of cementite up to the Curie temperature. The experimentally observed increase in low energy acoustic phonons affects the elastic behavior of Fe3C, increasing the isotropy of elastic response. First principles calculations link the observed phonon energy increases to specific vibrational modes that are polarized along the b-axis, which aligns with the closest Fe-Fe bonding direction. The nonharmonic behavior of the vibrational modes are discussed in the context of other observations of anomalous anisotropic magneto-volume behavior in Fe3C.

  4. Eulerian frequency analysis of structural vibrations from high-speed video

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venanzoni, Andrea; Siemens Industry Software NV, Interleuvenlaan 68, B-3001 Leuven; De Ryck, Laurent

    An approach for the analysis of the frequency content of structural vibrations from high-speed video recordings is proposed. The techniques and tools proposed rely on an Eulerian approach, that is, using the time history of pixels independently to analyse structural motion, as opposed to Lagrangian approaches, where the motion of the structure is tracked in time. The starting point is an existing Eulerian motion magnification method, which consists in decomposing the video frames into a set of spatial scales through a so-called Laplacian pyramid [1]. Each scale — or level — can be amplified independently to reconstruct a magnified motionmore » of the observed structure. The approach proposed here provides two analysis tools or pre-amplification steps. The first tool provides a representation of the global frequency content of a video per pyramid level. This may be further enhanced by applying an angular filter in the spatial frequency domain to each frame of the video before the Laplacian pyramid decomposition, which allows for the identification of the frequency content of the structural vibrations in a particular direction of space. This proposed tool complements the existing Eulerian magnification method by amplifying selectively the levels containing relevant motion information with respect to their frequency content. This magnifies the displacement while limiting the noise contribution. The second tool is a holographic representation of the frequency content of a vibrating structure, yielding a map of the predominant frequency components across the structure. In contrast to the global frequency content representation of the video, this tool provides a local analysis of the periodic gray scale intensity changes of the frame in order to identify the vibrating parts of the structure and their main frequencies. Validation cases are provided and the advantages and limits of the approaches are discussed. The first validation case consists of the frequency content retrieval of the tip of a shaker, excited at selected fixed frequencies. The goal of this setup is to retrieve the frequencies at which the tip is excited. The second validation case consists of two thin metal beams connected to a randomly excited bar. It is shown that the holographic representation visually highlights the predominant frequency content of each pixel and locates the global frequencies of the motion, thus retrieving the natural frequencies for each beam.« less

  5. Transverse vibration techniques : logs to structural systems

    Treesearch

    Robert J. Ross

    2008-01-01

    Transverse vibration as a nondestructive testing and evaluation technique was first examined in the early 1960s. Initial research and development efforts focused on clear wood, lumber, and laminated products. Out of those efforts, tools were developed that are used today to assess lumber properties. Recently, use of this technique has been investigated for evaluating a...

  6. Servomotors. (Latest Citations from the Aerospace Database)

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The bibliography contains citations concerning the design, testing, and application of servomotors. AC, DC, and brushless motor drives are discussed. Applications are examined, including use in hydraulic presses; teleprinters; machine tools; sewing machines; and servocontrol devices for instrumentation, robots, and aircraft control. Testing methods evaluate precision, vibration and vibration reduction, and stability of servomotors.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Bo; Zhao, Hongwei, E-mail: hwzhao@jlu.edu.cn, E-mail: khl69@163.com; Zhao, Dan

    It has always been a critical issue to understand the material removal behavior of Vibration-Assisted Machining (VAM), especially on atomic level. To find out the effects of vibration frequency on material removal response, a three-dimensional molecular dynamics (MD) model has been established in this research to investigate the effects of scratched groove, crystal defects on the surface quality, comparing with the Von Mises shear strain and tangential force in simulations during nano-scratching process. Comparisons are made among the results of simulations from different vibration frequency with the same scratching feed, depth, amplitude and crystal orientation. Copper potential in this simulationmore » is Embedded-Atom Method (EAM) potential. Interaction between copper and carbon atoms is Morse potential. Simulational results show that higher frequency can make groove smoother. Simulation with high frequency creates more dislocations to improve the machinability of copper specimen. The changing frequency does not have evident effects on Von Mises shear strain. Higher frequency can decrease the tangential force to reduce the consumption of cutting energy and tool wear. In conclusion, higher vibration frequency in VAM on mono-crystalline copper has positive effects on surface finish, machinablility and tool wear reduction.« less

  8. Use of piezoelectric dampers for improving the feel of golf clubs

    NASA Astrophysics Data System (ADS)

    Bianchini, Emanuele; Spangler, Ronald L., Jr.; Pandell, Tracy

    1999-06-01

    Several sports are based upon a tool (club, bat, stick) striking an object (ball, puck) across a field of play. Anytime two structures collide, vibration is created by the impact of the two. The impact of the objects excites the structural modes of the tool, creating a vibration that can be felt by the player, especially if the hit is not at a `sweet spot'. Vibration adversely affects both feel and performance. This paper explains how piezoelectric dampers were developed to reduce vibration and improve the feel of ball-impact sporting goods such as golf clubs. The paper describes how the dynamic characteristics of a golf club were calculated, at first in the free-free condition, and then during its operation conditions (the swing of the club, and the impact with the ball). The dynamic characteristics were used to develop a damper that addressed a specific, or multiple, modes of interest. The damper development and testing are detailed in this paper. Both objective laboratory tests and subjective player tests were performed to evaluate the effectiveness of the piezoelectric dampers. The results of the tests, along with published medical data on the sensitivity of the human body, were used to draw a correlation between human feel and vibration reduction.

  9. Hand-arm vibration syndrome: clinical characteristics, conventional electrophysiology and quantitative sensory testing.

    PubMed

    Rolke, Roman; Rolke, Silke; Vogt, Thomas; Birklein, Frank; Geber, Christian; Treede, Rolf-Detlef; Letzel, Stephan; Voelter-Mahlknecht, Susanne

    2013-08-01

    Workers exposed to vibrating tools may develop hand-arm vibration syndrome (HAVS). We assessed the somatosensory phenotype using quantitative sensory testing (QST) in comparison to electrophysiology to characterize (1) the most sensitive QST parameter for detecting sensory loss, (2) the correlation of QST and electrophysiology, and (3) the frequency of a carpal tunnel syndrome (CTS) in HAVS. QST, cold provocation tests, fine motor skills, and median nerve neurography were used. QST included thermal and mechanical detection and pain thresholds. Thirty-two patients were examined (54 ± 11 years, 91% men) at the more affected hand compared to 16 matched controls. Vibration detection threshold was the most sensitive parameter to detect sensory loss that was more pronounced in the sensitivity range of Pacinian (150 Hz, x12) than Meissner's corpuscles (20 Hz, x3). QST (84% abnormal) was more sensitive to detect neural dysfunction than conventional electrophysiology (37% abnormal). Motor (34%) and sensory neurography (25%) were abnormal in HAVS. CTS frequency was not increased (9.4%). Findings are consistent with a mechanically-induced, distally pronounced motor and sensory neuropathy independent of CTS. HAVS involves a neuropathy predominantly affecting large fibers with a sensory damage related to resonance frequencies of vibrating tools. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  10. A novel diamond micro-/nano-machining process for the generation of hierarchical micro-/nano-structures

    NASA Astrophysics Data System (ADS)

    Zhu, Zhiwei; To, Suet; Ehmann, Kornel F.; Xiao, Gaobo; Zhu, Wule

    2016-03-01

    A new mechanical micro-/nano-machining process that combines rotary spatial vibrations (RSV) of a diamond tool and the servo motions of the workpiece is proposed and applied for the generation of multi-tier hierarchical micro-/nano-structures. In the proposed micro-/nano-machining system, the servo motion, as the primary cutting motion generated by a slow-tool-servo, is adopted for the fine generation of the primary surfaces with complex shapes. The RSV, as the tertiary cutting operation, is superimposed on the secondary fundamental rotary cutting motion to construct secondary nano-structures on the primary surface. Since the RSV system generally works at much higher frequencies and motion resolution than the primary and secondary motions, it leads to an inherent hierarchical cutting architecture. To investigate the machining performance, complex micro-/nano-structures were generated and explored by both numerical simulations and actual cutting tests. Rotary vibrations of the diamond tool at a constant rotational distance offer an inherent constant cutting velocity, leading to the ability for the generation of homogeneous micro-/nano-structures with fixed amplitudes and frequencies of the vibrations, even over large-scale surfaces. Furthermore, by deliberately combining the non-resonant three-axial vibrations and the servo motion, the generation of a variety of micro-/nano-structures with complex shapes and with flexibly tunable feature sizes can be achieved.

  11. Portable devices and mobile instruments for infectious diseases point-of-care testing.

    PubMed

    Bissonnette, Luc; Bergeron, Michel G

    2017-05-01

    Rapidity, simplicity, and portability are highly desirable characteristics of tests and devices designed for performing diagnostics at the point of care (POC), either near patients managed in healthcare facilities or to offer bioanalytical alternatives in external settings. By reducing the turnaround time of the diagnostic cycle, POC diagnostics can reduce the dissemination, morbidity, and mortality of infectious diseases and provide tools to control the global threat of antimicrobial resistance. Areas covered: A literature search of PubMed and Google Scholar, and extensive mining of specialized publications, Internet resources, and manufacturers' websites have been used to organize and write this overview of the challenges and requirements associated with the development of portable sample-to-answer diagnostics, and showcase relevant examples of handheld devices, portable instruments, and less mobile systems which may or could be operated at POC. Expert commentary: Rapid (<1 h) diagnostics can contribute to control infectious diseases and antimicrobial resistant pathogens. Portable devices or instruments enabling sample-to-answer bioanalysis can provide rapid, robust, and reproducible testing at the POC or close from it. Beyond testing, to realize some promises of personalized/precision medicine, it will be critical to connect instruments to healthcare data management systems, to efficiently link decentralized testing results to the electronic medical record of patients.

  12. Configurable, wearable sensing and vibrotactile feedback system for real-time postural balance and gait training: proof-of-concept.

    PubMed

    Xu, Junkai; Bao, Tian; Lee, Ung Hee; Kinnaird, Catherine; Carender, Wendy; Huang, Yangjian; Sienko, Kathleen H; Shull, Peter B

    2017-10-11

    Postural balance and gait training is important for treating persons with functional impairments, however current systems are generally not portable and are unable to train different types of movements. This paper describes a proof-of-concept design of a configurable, wearable sensing and feedback system for real-time postural balance and gait training targeted for home-based treatments and other portable usage. Sensing and vibrotactile feedback are performed via eight distributed, wireless nodes or "Dots" (size: 22.5 × 20.5 × 15.0 mm, weight: 12.0 g) that can each be configured for sensing and/or feedback according to movement training requirements. In the first experiment, four healthy older adults were trained to reduce medial-lateral (M/L) trunk tilt while performing balance exercises. When trunk tilt deviated too far from vertical (estimated via a sensing Dot on the lower spine), vibrotactile feedback (via feedback Dots placed on the left and right sides of the lower torso) cued participants to move away from the vibration and back toward the vertical no feedback zone to correct their posture. A second experiment was conducted with the same wearable system to train six healthy older adults to alter their foot progression angle in real-time by internally or externally rotating their feet while walking. Foot progression angle was estimated via a sensing Dot adhered to the dorsal side of the foot, and vibrotactile feedback was provided via feedback Dots placed on the medial and lateral sides of the mid-shank cued participants to internally or externally rotate their foot away from vibration. In the first experiment, the wearable system enabled participants to significantly reduce trunk tilt and increase the amount of time inside the no feedback zone. In the second experiment, all participants were able to adopt new gait patterns of internal and external foot rotation within two minutes of real-time training with the wearable system. These results suggest that the configurable, wearable sensing and feedback system is portable and effective for different types of real-time human movement training and thus may be suitable for home-based or clinic-based rehabilitation applications.

  13. From Sour Grapes to Low-Hanging Fruit: A Case Study Demonstrating a Practical Strategy for Natural Language Processing Portability.

    PubMed

    Johnson, Stephen B; Adekkanattu, Prakash; Campion, Thomas R; Flory, James; Pathak, Jyotishman; Patterson, Olga V; DuVall, Scott L; Major, Vincent; Aphinyanaphongs, Yindalon

    2018-01-01

    Natural Language Processing (NLP) holds potential for patient care and clinical research, but a gap exists between promise and reality. While some studies have demonstrated portability of NLP systems across multiple sites, challenges remain. Strategies to mitigate these challenges can strive for complex NLP problems using advanced methods (hard-to-reach fruit), or focus on simple NLP problems using practical methods (low-hanging fruit). This paper investigates a practical strategy for NLP portability using extraction of left ventricular ejection fraction (LVEF) as a use case. We used a tool developed at the Department of Veterans Affair (VA) to extract the LVEF values from free-text echocardiograms in the MIMIC-III database. The approach showed an accuracy of 98.4%, sensitivity of 99.4%, a positive predictive value of 98.7%, and F-score of 99.0%. This experience, in which a simple NLP solution proved highly portable with excellent performance, illustrates the point that simple NLP applications may be easier to disseminate and adapt, and in the short term may prove more useful, than complex applications.

  14. A portable Raman acoustic levitation spectroscopic system for the identification and environmental monitoring of algal cells.

    PubMed

    Wood, Bayden R; Heraud, Philip; Stojkovic, Slobodanka; Morrison, Danielle; Beardall, John; McNaughton, Don

    2005-08-01

    We report the coupling of a portable Raman spectrometer to an acoustic levitation device to enable environmental monitoring and the potential taxonomic identification of microalgae. Spectra of living cells were recorded at 785 nm using a fiber-optic probe coupled to a portable Raman spectrometer. The spectra exhibit an excellent signal-to-noise ratio and clearly show bands from chlorophyll a and beta-carotene. Spectra of levitated photobleached microalgae clearly show a reduction in chlorophyll a concentration relative to beta-carotene after 10 min of exposure to a quartz halogen lamp. Spectra recorded from levitated nitrogen-limited cells also show a significant reduction in bands associated with chlorophyll a, as compared to nitrogen-replete cells. To investigate the diagnostic capability of the technique, four species of microalgae were analyzed. Good quality spectra of all four species were obtained showing varying ratios of beta-carotene to chlorophyll. The combination of an acoustic levitation device and a portable Raman spectrometer shows potential as a taxonomic and environmental monitoring tool with direct application to field studies in remote environments.

  15. Prediction of passenger ride quality in a multifactor environment

    NASA Technical Reports Server (NTRS)

    Dempsey, T. K.; Leatherwood, J. D.

    1976-01-01

    A model being developed, permits the understanding and prediction of passenger discomfort in a multifactor environment with particular emphasis upon combined noise and vibration. The model has general applicability to diverse transportation systems and provides a means of developing ride quality design criteria as well as a diagnostic tool for identifying the vibration and/or noise stimuli causing discomfort. Presented are: (1) a review of the basic theoretical and mathematical computations associated with the model, (2) a discussion of methodological and criteria investigations for both the vertical and roll axes of vibration, (3) a description of within-axis masking of discomfort responses for the vertical axis, thereby allowing prediction of the total discomfort due to any random vertical vibration, (4) a discussion of initial data on between-axis masking, and (5) discussion of a study directed towards extension of the vibration model to the more general case of predicting ride quality in the combined noise and vibration environments.

  16. Biomolecular Imaging with Coherent Nonlinear Vibrational Microscopy

    PubMed Central

    Chung, Chao-Yu; Boik, John; Potma, Eric O.

    2014-01-01

    Optical imaging with spectroscopic vibrational contrast is a label-free solution for visualizing, identifying, and quantifying a wide range of biomolecular compounds in biological materials. Both linear and nonlinear vibrational microscopy techniques derive their imaging contrast from infrared active or Raman allowed molecular transitions, which provide a rich palette for interrogating chemical and structural details of the sample. Yet nonlinear optical methods, which include both second-order sum-frequency generation (SFG) and third-order coherent Raman scattering (CRS) techniques, offer several improved imaging capabilities over their linear precursors. Nonlinear vibrational microscopy features unprecedented vibrational imaging speeds, provides strategies for higher spatial resolution, and gives access to additional molecular parameters. These advances have turned vibrational microscopy into a premier tool for chemically dissecting live cells and tissues. This review discusses the molecular contrast of SFG and CRS microscopy and highlights several of the advanced imaging capabilities that have impacted biological and biomedical research. PMID:23245525

  17. 33 CFR 150.607 - What are the general safe working requirements?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... machinery, cranes, derricks, portable power tools, and, most importantly, safety gear must be used in a safe... subchapter. (b) All machinery and equipment must be maintained in proper working order or removed. Personal...

  18. 33 CFR 150.607 - What are the general safe working requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... machinery, cranes, derricks, portable power tools, and, most importantly, safety gear must be used in a safe... subchapter. (b) All machinery and equipment must be maintained in proper working order or removed. Personal...

  19. 33 CFR 150.607 - What are the general safe working requirements?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... machinery, cranes, derricks, portable power tools, and, most importantly, safety gear must be used in a safe... subchapter. (b) All machinery and equipment must be maintained in proper working order or removed. Personal...

  20. An investigation of vibration-induced protein desorption mechanism using a micromachined membrane and PZT plate.

    PubMed

    Yeh, Po Ying; Le, Yevgeniya; Kizhakkedathu, Jayachandran N; Chiao, Mu

    2008-10-01

    A micromachined vibrating membrane is used to remove adsorbed proteins on a surface. A lead zirconate titanate (PZT) composite (3 x 1 x 0.5 mm) is attached to a silicon membrane (2,000 x 500 x 3 microm) and vibrates in a flexural plate wave (FPW) mode with wavelength of 4,000/3 microm at a resonant frequency of 308 kHz. The surface charge on the membrane and fluid shear stress contribute in minimizing the protein adsorption on the SiO(2) surface. In vitro characterization shows that 57 +/- 10% of the adsorbed bovine serum albumin (BSA), 47 +/- 13% of the immunoglobulin G (IgG), and 55.3~59.2 +/- 8% of the proteins from blood plasma are effectively removed from the vibrating surface. A simulation study of the vibration-frequency spectrum and vibrating amplitude distribution matches well with the experimental data. Potentially, a microelectromechanical system (MEMS)-based vibrating membrane could be the tool to minimize biofouling of in vivo MEMS devices.

  1. Mode-selective vibrational modulation of charge transport in organic electronic devices

    PubMed Central

    Bakulin, Artem A.; Lovrincic, Robert; Yu, Xi; Selig, Oleg; Bakker, Huib J.; Rezus, Yves L. A.; Nayak, Pabitra K.; Fonari, Alexandr; Coropceanu, Veaceslav; Brédas, Jean-Luc; Cahen, David

    2015-01-01

    The soft character of organic materials leads to strong coupling between molecular, nuclear and electronic dynamics. This coupling opens the way to influence charge transport in organic electronic devices by exciting molecular vibrational motions. However, despite encouraging theoretical predictions, experimental realization of such approach has remained elusive. Here we demonstrate experimentally that photoconductivity in a model organic optoelectronic device can be modulated by the selective excitation of molecular vibrations. Using an ultrafast infrared laser source to create a coherent superposition of vibrational motions in a pentacene/C60 photoresistor, we observe that excitation of certain modes in the 1,500–1,700 cm−1 region leads to photocurrent enhancement. Excited vibrations affect predominantly trapped carriers. The effect depends on the nature of the vibration and its mode-specific character can be well described by the vibrational modulation of intermolecular electronic couplings. This presents a new tool for studying electron–phonon coupling and charge dynamics in (bio)molecular materials. PMID:26246039

  2. Mode-selective vibrational modulation of charge transport in organic electronic devices

    NASA Astrophysics Data System (ADS)

    Bakulin, Artem A.; Lovrincic, Robert; Yu, Xi; Selig, Oleg; Bakker, Huib J.; Rezus, Yves L. A.; Nayak, Pabitra K.; Fonari, Alexandr; Coropceanu, Veaceslav; Brédas, Jean-Luc; Cahen, David

    2015-08-01

    The soft character of organic materials leads to strong coupling between molecular, nuclear and electronic dynamics. This coupling opens the way to influence charge transport in organic electronic devices by exciting molecular vibrational motions. However, despite encouraging theoretical predictions, experimental realization of such approach has remained elusive. Here we demonstrate experimentally that photoconductivity in a model organic optoelectronic device can be modulated by the selective excitation of molecular vibrations. Using an ultrafast infrared laser source to create a coherent superposition of vibrational motions in a pentacene/C60 photoresistor, we observe that excitation of certain modes in the 1,500-1,700 cm-1 region leads to photocurrent enhancement. Excited vibrations affect predominantly trapped carriers. The effect depends on the nature of the vibration and its mode-specific character can be well described by the vibrational modulation of intermolecular electronic couplings. This presents a new tool for studying electron-phonon coupling and charge dynamics in (bio)molecular materials.

  3. Advanced Spacesuit Portable Life Support System Packaging Concept Mock-Up Design & Development

    NASA Technical Reports Server (NTRS)

    O''Connell, Mary K.; Slade, Howard G.; Stinson, Richard G.

    1998-01-01

    A concentrated development effort was begun at NASA Johnson Space Center to create an advanced Portable Life Support System (PLSS) packaging concept. Ease of maintenance, technological flexibility, low weight, and minimal volume are targeted in the design of future micro-gravity and planetary PLSS configurations. Three main design concepts emerged from conceptual design techniques and were carried forth into detailed design, then full scale mock-up creation. "Foam", "Motherboard", and "LEGOtm" packaging design concepts are described in detail. Results of the evaluation process targeted maintenance, robustness, mass properties, and flexibility as key aspects to a new PLSS packaging configuration. The various design tools used to evolve concepts into high fidelity mock ups revealed that no single tool was all encompassing, several combinations were complimentary, the devil is in the details, and, despite efforts, many lessons were learned only after working with hardware.

  4. Alview: Portable Software for Viewing Sequence Reads in BAM Formatted Files.

    PubMed

    Finney, Richard P; Chen, Qing-Rong; Nguyen, Cu V; Hsu, Chih Hao; Yan, Chunhua; Hu, Ying; Abawi, Massih; Bian, Xiaopeng; Meerzaman, Daoud M

    2015-01-01

    The name Alview is a contraction of the term Alignment Viewer. Alview is a compiled to native architecture software tool for visualizing the alignment of sequencing data. Inputs are files of short-read sequences aligned to a reference genome in the SAM/BAM format and files containing reference genome data. Outputs are visualizations of these aligned short reads. Alview is written in portable C with optional graphical user interface (GUI) code written in C, C++, and Objective-C. The application can run in three different ways: as a web server, as a command line tool, or as a native, GUI program. Alview is compatible with Microsoft Windows, Linux, and Apple OS X. It is available as a web demo at https://cgwb.nci.nih.gov/cgi-bin/alview. The source code and Windows/Mac/Linux executables are available via https://github.com/NCIP/alview.

  5. A Web-based cost-effective training tool with possible application to brain injury rehabilitation.

    PubMed

    Wang, Peijun; Kreutzer, Ina Anna; Bjärnemo, Robert; Davies, Roy C

    2004-06-01

    Virtual reality (VR) has provoked enormous interest in the medical community. In particular, VR offers therapists new approaches for improving rehabilitation effects. However, most of these VR assistant tools are not very portable, extensible or economical. Due to the vast amount of 3D data, they are not suitable for Internet transfer. Furthermore, in order to run these VR systems smoothly, special hardware devices are needed. As a result, existing VR assistant tools tend to be available in hospitals but not in patients' homes. To overcome these disadvantages, as a case study, this paper proposes a Web-based Virtual Ticket Machine, called WBVTM, using VRML [VRML Consortium, The Virtual Reality Modeling Language: International Standard ISO/IEC DIS 14772-1, 1997, available at ], Java and EAI (External Authoring Interface) [Silicon Graphics, Inc., The External Authoring Interface (EAI), available at ], to help people with acquired brain injury (ABI) to relearn basic living skills at home at a low cost. As these technologies are open standard and feature usability on the Internet, WBVTM achieves the goals of portability, easy accessibility and cost-effectiveness.

  6. Analysis tool and methodology design for electronic vibration stress understanding and prediction

    NASA Astrophysics Data System (ADS)

    Hsieh, Sheng-Jen; Crane, Robert L.; Sathish, Shamachary

    2005-03-01

    The objectives of this research were to (1) understand the impact of vibration on electronic components under ultrasound excitation; (2) model the thermal profile presented under vibration stress; and (3) predict stress level given a thermal profile of an electronic component. Research tasks included: (1) retrofit of current ultrasonic/infrared nondestructive testing system with sensory devices for temperature readings; (2) design of software tool to process images acquired from the ultrasonic/infrared system; (3) developing hypotheses and conducting experiments; and (4) modeling and evaluation of electronic vibration stress levels using a neural network model. Results suggest that (1) an ultrasonic/infrared system can be used to mimic short burst high vibration loads for electronics components; (2) temperature readings for electronic components under vibration stress are consistent and repeatable; (3) as stress load and excitation time increase, temperature differences also increase; (4) components that are subjected to a relatively high pre-stress load, followed by a normal operating load, have a higher heating rate and lower cooling rate. These findings are based on grayscale changes in images captured during experimentation. Discriminating variables and a neural network model were designed to predict stress levels given temperature and/or grayscale readings. Preliminary results suggest a 15.3% error when using grayscale change rate and 12.8% error when using average heating rate within the neural network model. Data were obtained from a high stress point (the corner) of the chip.

  7. Hand-arm vibration syndrome in South African gold miners.

    PubMed

    Nyantumbu, Busi; Barber, Chris M; Ross, Mary; Curran, Andrew D; Fishwick, David; Dias, Belinda; Kgalamono, Spo; Phillips, James I

    2007-01-01

    Hand-arm vibration syndrome (HAVS) is associated with the use of hand-held vibrating tools. Affected workers may experience symptoms of tingling, numbness, loss of grip strength and pain. Loss of dexterity may impair everyday activities, and potentially increase the risk of occupational accidents. Although high vibration levels (up to 31 m/s(2)) have been measured in association with rock drills, HAVS has not been scientifically evaluated in the South African mining industry. The aim of this study was to determine the prevalence and severity of HAVS in South African gold miners, and to identify the tools responsible. A cross-sectional study was conducted in a single South African gold-mine. Participants were randomly selected from mineworkers returning from annual leave, comprising 156 subjects with occupational exposure to vibration, and 140 workers with no exposure. Miners who consented to participate underwent a clinical HAVS assessment following the UK Health and Safety Laboratory protocol. The prevalence of HAVS in vibration-exposed gold miners was 15%, with a mean latent period of 5.6 years. Among the non-exposed comparison group, 5% had signs and symptoms indistinguishable from HAVS. This difference was statistically significant (P < 0.05). All the cases of HAVS gave a history of exposure to rock drills. The study has diagnosed the first cases of HAVS in the South African mining industry. The prevalence of HAVS was lower than expected, and possible explanations for this may include a survivor population, and lack of vascular symptom reporting due to warm-ambient temperatures.

  8. KS-Detect – Validation of Solar Thermal PCR for the Diagnosis of Kaposi’s Sarcoma Using Pseudo-Biopsy Samples

    PubMed Central

    Snodgrass, Ryan; Gardner, Andrea; Jiang, Li; Fu, Cheng; Cesarman, Ethel; Erickson, David

    2016-01-01

    Resource-limited settings present unique engineering challenges for medical diagnostics. Diagnosis is often needed for those unable to reach central healthcare systems, making portability and independence from traditional energy infrastructure essential device parameters. In 2014, our group presented a microfluidic device that performed a solar-powered variant of the polymerase chain reaction, which we called solar thermal PCR. In this work, we expand on our previous effort by presenting an integrated, portable, solar thermal PCR system targeted towards the diagnosis of Kaposi’s sarcoma. We call this system KS-Detect, and we now report the system’s performance as a diagnostic tool using pseudo-biopsy samples made from varying concentrations of human lymphoma cell lines positive for the KS herpesvirus (KSHV). KS-Detect achieved 83% sensitivity and 70% specificity at high (≥10%) KSHV+ cell concentrations when diagnosing pseudo-biopsy samples by smartphone image. Using histology, we confirm that our prepared pseudo-biopsies contain similar KSHV+ cell concentrations as human biopsies positive for KS. Through our testing of samples derived from human cell lines, we validate KS-Detect as a viable, portable KS diagnostic tool, and we identify critical engineering considerations for future solar-thermal PCR devices. PMID:26799834

  9. Stand-Sit Microchip for High-Throughput, Multiplexed Analysis of Single Cancer Cells.

    PubMed

    Ramirez, Lisa; Herschkowitz, Jason I; Wang, Jun

    2016-09-01

    Cellular heterogeneity in function and response to therapeutics has been a major challenge in cancer treatment. The complex nature of tumor systems calls for the development of advanced multiplexed single-cell tools that can address the heterogeneity issue. However, to date such tools are only available in a laboratory setting and don't have the portability to meet the needs in point-of-care cancer diagnostics. Towards that application, we have developed a portable single-cell system that is comprised of a microchip and an adjustable clamp, so on-chip operation only needs pipetting and adjusting of clamping force. Up to 10 proteins can be quantitated from each cell with hundreds of single-cell assays performed in parallel from one chip operation. We validated the technology and analyzed the oncogenic signatures of cancer stem cells by quantitating both aldehyde dehydrogenase (ALDH) activities and 5 signaling proteins in single MDA-MB-231 breast cancer cells. The technology has also been used to investigate the PI3K pathway activities of brain cancer cells expressing mutant epidermal growth factor receptor (EGFR) after drug intervention targeting EGFR signaling. Our portable single-cell system will potentially have broad application in the preclinical and clinical settings for cancer diagnosis in the future.

  10. Piezoelectric shunt damping of a circular saw blade with autonomous power supply for noise and vibration reduction

    NASA Astrophysics Data System (ADS)

    Pohl, Martin; Rose, Michael

    2016-01-01

    Circular saws are widespread tools for machining metal, wood or even ceramics. Due to the thin blade and excitation by the workpiece contact of the cutting edges, circular saws are prone to vibration and intense noise emission. Damping the blade will lower the hearing protection requirements of the users and possibly increase precision. Therefore a new damping concept for circular saw blades is presented in this paper. It is based on negative capacitance shunted piezoelectric transducers which are applied to the saw blade core. The required energy for the electronics is harvested from the rotation by a generator, so that no change of the machine tool is required. All components are integrated into an autonomous saw tool. Finally, the system is experimentally investigated without rotation, in idling and in cutting condition in a circular saw test stand in the Institute for Machine Tools and Production Engineering (IWF) at TU Braunschweig. The experimental investigation shows a good reduction of the vibration amplitude over a wide frequency range in the non-rotating condition. When rotating, the damping effect is lower and limited to some narrow frequency bands. The proposed reason for the reduced damping effect in rotating condition consists in the saturation of the electronic circuits due to the limited supply voltage capabilities.

  11. Astronauts Newman and Walz evaluate tools for use on HST servicing mission

    NASA Image and Video Library

    1993-09-16

    STS051-06-037 (16 Sept 1993) --- Astronauts Carl E. Walz (foreground) and James H. Newman evaluate some important gear. Walz reaches for the Power Ratchet Tool (PRT) while Newman checks out mobility on the Portable Foot Restraint (PFR) near the Space Shuttle Discovery's starboard Orbital Maneuvering System (OMS) pod. The tools and equipment will be instrumental on some of the five periods of extravehicular activity (EVA) scheduled for the Hubble Space Telescope (HST) STS-61 servicing mission later this year.

  12. The Effectiveness of Videotape Programs as a Communication Tool in the Small-Scale Livestock for Rural Farming Women Project, Honduras.

    ERIC Educational Resources Information Center

    Johnson-Dean, Lynn

    This study examines economic development in Third World countries and the use of portable video systems in development projects. The study, conducted in 1985, attempts to measure the level of effectiveness of videotape programs as a communication tool for training rural subsistence women in Honduras in technical aspects of pig-keeping. Classical…

  13. Manufacturing Process Applications Team (MATeam)

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The activities of the Manufacturing Process Applications Team concerning the promotion of joint Industry/Federal Agency/NASA funded research and technology operating plan (RTOP) programs are reported. Direct transfers occurred in cutting tools, laser wire stripping, soldering, and portable X-ray unit technology. TROP program funding approval was obtained for the further development of the cutting tool Sialon and development of an automated nondestructive fracture toughness testing system.

  14. An experimental topographic amplification study at Los Alamos National Laboratory using ambient vibrations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stolte, Andrew C.; Cox, Brady R.; Lee, Richard C.

    An experimental study aimed at investigating potential topographic amplification of seismic waves was conducted on a 50-m-tall and 185-m-wide soft-rock ridge located at Los Alamos National Laboratory near Los Alamos, New Mexico. Ten portable broadband seismograph stations were placed in arrays across the ridge and left to record ambient vibration data for ~9 hours. Clear evidence of topographic amplification was observed by comparing spectral ratios calculated from ambient noise recordings at the toe, slope, and crest of the instrumented ridge. The inferred resonance frequency of the ridge obtained from the experimental recordings was found to agree well with several simplemore » estimates of the theoretical resonance frequency based on its geometry and stiffness. Results support the feasibility of quantifying the frequency range of topographic amplification solely using ambient vibrations, rather than strong or weak ground motions. Additionally, comparisons have been made between a number of widely used experimental methods for quantifying topographic effects, such as the standard spectral ratio, median reference method, and horizontal-to-vertical spectral ratio. As a result, differences in the amplification and frequency range of topographic effects indicated by these methods highlight the importance of choosing a reference condition that is appropriate for the site-specific conditions and goals associated with an experimental topographic amplification study.« less

  15. An experimental topographic amplification study at Los Alamos National Laboratory using ambient vibrations

    DOE PAGES

    Stolte, Andrew C.; Cox, Brady R.; Lee, Richard C.

    2017-03-14

    An experimental study aimed at investigating potential topographic amplification of seismic waves was conducted on a 50-m-tall and 185-m-wide soft-rock ridge located at Los Alamos National Laboratory near Los Alamos, New Mexico. Ten portable broadband seismograph stations were placed in arrays across the ridge and left to record ambient vibration data for ~9 hours. Clear evidence of topographic amplification was observed by comparing spectral ratios calculated from ambient noise recordings at the toe, slope, and crest of the instrumented ridge. The inferred resonance frequency of the ridge obtained from the experimental recordings was found to agree well with several simplemore » estimates of the theoretical resonance frequency based on its geometry and stiffness. Results support the feasibility of quantifying the frequency range of topographic amplification solely using ambient vibrations, rather than strong or weak ground motions. Additionally, comparisons have been made between a number of widely used experimental methods for quantifying topographic effects, such as the standard spectral ratio, median reference method, and horizontal-to-vertical spectral ratio. As a result, differences in the amplification and frequency range of topographic effects indicated by these methods highlight the importance of choosing a reference condition that is appropriate for the site-specific conditions and goals associated with an experimental topographic amplification study.« less

  16. Design of In Situ Poled Ce(3+)-Doped Electrospun PVDF/Graphene Composite Nanofibers for Fabrication of Nanopressure Sensor and Ultrasensitive Acoustic Nanogenerator.

    PubMed

    Garain, Samiran; Jana, Santanu; Sinha, Tridib Kumar; Mandal, Dipankar

    2016-02-01

    We report an efficient, low-cost in situ poled fabrication strategy to construct a large area, highly sensitive, flexible pressure sensor by electrospun Ce(3+) doped PVDF/graphene composite nanofibers. The entire device fabrication process is scalable and enabling to large-area integration. It can able to detect imparting pressure as low as 2 Pa with high level of sensitivity. Furthermore, Ce(3+)-doped PVDF/graphene nanofiber based ultrasensitive pressure sensors can also be used as an effective nanogenerator as it generating an output voltage of 11 V with a current density ∼6 nA/cm(2) upon repetitive application of mechanical stress that could lit up 10 blue light emitting diodes (LEDs) instantaneously. Furthermore, to use it in environmental random vibrations (such as wind flow, water fall, transportation of vehicles, etc.), nanogenerator is integrated with musical vibration that exhibits to power up three blue LEDs instantly that promises as an ultrasensitive acoustic nanogenerator (ANG). The superior sensing properties in conjunction with mechanical flexibility, integrability, and robustness of nanofibers enabled real-time monitoring of sound waves as well as detection of different type of musical vibrations. Thus, ANG promises to use as an ultrasensitive pressure sensor, mechanical energy harvester, and effective power source for portable electronic and wearable devices.

  17. Automated Portable Test (APT) System: overview and prospects

    NASA Technical Reports Server (NTRS)

    Bittner, A. C.; Smith, M. G.; Kennedy, R. S.; Staley, C. F.; Harbeson, M. M.

    1985-01-01

    The Automated Portable Test (APT) System is a notebook-sized, computer-based, human-performance and subjective-status assessment system. It is now being used in a wide range of environmental studies (e.g., simulator aftereffects, flight tests, drug effects, and hypoxia). Three questionnaires and 15 performance tests have been implemented, and the adaptation of 30 more tests is underway or is planned. The APT System is easily transportable, is inexpensive, and has the breadth of expansion options required for field and laboratory applications. The APT System is a powerful and expandable tool for human assessment in remote and unusual environments.

  18. Split Stirling linear cryogenic cooler for a new generation of high temperature infrared imagers

    NASA Astrophysics Data System (ADS)

    Veprik, A.; Zechtzer, S.; Pundak, N.

    2010-04-01

    Split linear cryocoolers find use in a variety of infrared equipment installed in airborne, heliborne, marine and vehicular platforms along with hand held and ground fixed applications. An upcoming generation of portable, high-definition night vision imagers will rely on the high-temperature infrared detectors, operating at elevated temperatures, ranging from 95K to 200K, while being able to show the performance indices comparable with these of their traditional 77K competitors. Recent technological advances in industrial development of such high-temperature detectors initialized attempts for developing compact split Stirling linear cryogenic coolers. Their known advantages, as compared to the rotary integral coolers, are superior flexibility in the system packaging, constant and relatively high driving frequency, lower wideband vibration export, unsurpassed reliability and aural stealth. Unfortunately, such off-the-shelf available linear cryogenic coolers still cannot compete with rotary integral rivals in terms of size, weight and power consumption. Ricor developed the smallest in the range, 1W@95K, linear split Stirling cryogenic cooler for demanding infrared applications, where power consumption, compactness, vibration, aural noise and ownership costs are of concern.

  19. The vibrational properties of the bee-killer imidacloprid insecticide: A molecular description

    NASA Astrophysics Data System (ADS)

    Moreira, Antônio A. G.; De Lima-Neto, Pedro; Caetano, Ewerton W. S.; Barroso-Neto, Ito L.; Freire, Valder N.

    2017-10-01

    The chemical imidacloprid belongs to the neonicotinoids insecticide class, widely used for insect pest control mainly for crop protection. However, imidacloprid is a non-selective agrochemical to the insects and it is able to kill the most important pollinators, the bees. The high toxicity of imidacloprid requires controlled release and continuous monitoring. For this purpose, high performance liquid chromatography (HPLC) is usually employed; infrared and Raman spectroscopy, however, are simple and viable techniques that can be adapted to portable devices for field application. In this communication, state-of-the-art quantum level simulations were used to predict the infrared and Raman spectra of the most stable conformer of imidacloprid. Four molecular geometries were investigated in vacuum and solvated within the Density Functional Theory (DFT) approach employing the hybrid meta functional M06-2X and the hybrid functional B3LYP. The M062X/PCM model proved to be the best to predict structural features, while the values of harmonic vibrational frequencies were predicted more accurately using the B3LYP functional.

  20. An MRI-compatible hand sensory vibrotactile system.

    PubMed

    Wang, Fa; Lakshminarayanan, Kishor; Slota, Gregory P; Seo, Na Jin; Webster, John G

    2015-01-01

    Recently, the application of vibrotactile noise to the wrist or back of the hand has been shown to enhance fingertip tactile sensory perception (Enders et al 2013), supporting the potential for an assistive device worn at the wrist, that generates minute vibrations to help the elderly or patients with sensory deficit. However, knowledge regarding the detailed physiological mechanism behind this sensory improvement in the central nervous system, especially in the human brain, is limited, hindering progress in development and use of such assistive devices. To enable investigation of the impact of vibrotactile noise on sensorimotor brain activity in humans, a magnetic resonance imaging (MRI)-compatible vibrotactile system was developed to provide vibrotactile noise during an MRI of the brain. The vibrotactile system utilizes a remote (outside the MR room) signal amplifier which provides a voltage from -40 to +40 V to drive a 12 mm diameter piezoelectric vibrator (inside the MR room). It is portable and is found to be MRI-compatible which enables its use for neurologic investigation with MRI. The system was also found to induce an improvement in fingertip tactile sensation, consistent with the previous study.

  1. KSC-2014-2275

    NASA Image and Video Library

    2014-04-22

    CAPE CANAVERAL, Fla. - Inside the Operations and Checkout Building high bay at NASA’s Kennedy Space Center in Florida, the Orion crew module is positioned on a special portable test chamber and prepared for a multi-point random vibration test. Accelerometers and strain gages have been attached to Orion in various locations. During a series of tests, each lasting only 30 seconds, Orion will be subjected to gradually increasing levels of vibrations that represent levels the vehicle would experience during launch, orbit and descent. The data is reviewed in order to assess the health of the crew module. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of the Orion is scheduled to launch later this year atop a Delta IV rocket and in 2017 on NASA’s Space Launch System rocket. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Daniel Casper

  2. Measured Rattle Threshold of Residential House Windows

    NASA Technical Reports Server (NTRS)

    Sizov, Natalia; Schultz, Troy; Hobbs, Christopher; Klos, Jacob

    2008-01-01

    Window rattle is a common indoor noise effect in houses exposed to low frequency noise from such sources as railroads, blast noise and sonic boom. Human perception of rattle can be negative that is a motivating factor of the current research effort to study sonic boom induced window rattle. A rattle study has been conducted on residential houses containing windows of different construction at a variety of geographic locations within the United States. Windows in these houses were excited by a portable, high-powered loudspeaker and enclosure specifically designed to be mounted on the house exterior to cover an entire window. Window vibration was measured with accelerometers placed on different window components. Reference microphones were also placed inside the house and inside of the loudspeaker box. Swept sine excitation was used to identify the vibration threshold at which the response of the structure becomes non-linear and begins to rattle. Initial results from this study are presented and discussed. Future efforts will continue to explore the rattle occurrence in windows of residential houses exposed to sonic booms.

  3. Application of gas-fluid atomization technology in ultrosonic vibration cutting titanium alloy workpiece

    NASA Astrophysics Data System (ADS)

    Zhou, Zhimin; Zhang, Yuangliang; Li, Xiaoyan; Sun, Baoyuan

    2009-11-01

    To further improve machined surface quality of diamond cutting titanium workpiece and reduce diamond tool wear, it puts forward a kind of machining technology with mixture of carbon dioxide gas, water and vegetable oil atomized mist as cooling media in the paper. The cooling media is sprayed to cutting area through gas-liquid atomizer device to achieve purpose of cooling, lubricating, and protecting diamond tool. Experiments indicate that carbon dioxide gas can touch cutting surface more adequately through using gas-liquid atomization technology, which makes iron atoms of cutting surface cause a chemical reaction directly with carbon in carbon dioxide gas and reduce graphitizing degree of diamond tool. Thus, this technology of using gas-liquid atomization and ultrasonic vibration together for cutting Titanium Alloy is able to improve machined surface quality of workpiece and slow of diamond tool wear.

  4. Structural-Vibration-Response Data Analysis

    NASA Technical Reports Server (NTRS)

    Smith, W. R.; Hechenlaible, R. N.; Perez, R. C.

    1983-01-01

    Computer program developed as structural-vibration-response data analysis tool for use in dynamic testing of Space Shuttle. Program provides fast and efficient time-domain least-squares curve-fitting procedure for reducing transient response data to obtain structural model frequencies and dampings from free-decay records. Procedure simultaneously identifies frequencies, damping values, and participation factors for noisy multiple-response records.

  5. Deducing Electronic Unit Internal Response During a Vibration Test Using a Lumped Parameter Modeling Approach

    NASA Technical Reports Server (NTRS)

    Van Dyke, Michael B.

    2014-01-01

    During random vibration testing of electronic boxes there is often a desire to know the dynamic response of certain internal printed wiring boards (PWBs) for the purpose of monitoring the response of sensitive hardware or for post-test forensic analysis in support of anomaly investigation. Due to restrictions on internally mounted accelerometers for most flight hardware there is usually no means to empirically observe the internal dynamics of the unit, so one must resort to crude and highly uncertain approximations. One common practice is to apply Miles Equation, which does not account for the coupled response of the board in the chassis, resulting in significant over- or under-prediction. This paper explores the application of simple multiple-degree-of-freedom lumped parameter modeling to predict the coupled random vibration response of the PWBs in their fundamental modes of vibration. A simple tool using this approach could be used during or following a random vibration test to interpret vibration test data from a single external chassis measurement to deduce internal board dynamics by means of a rapid correlation analysis. Such a tool might also be useful in early design stages as a supplemental analysis to a more detailed finite element analysis to quickly prototype and analyze the dynamics of various design iterations. After developing the theoretical basis, a lumped parameter modeling approach is applied to an electronic unit for which both external and internal test vibration response measurements are available for direct comparison. Reasonable correlation of the results demonstrates the potential viability of such an approach. Further development of the preliminary approach presented in this paper will involve correlation with detailed finite element models and additional relevant test data.

  6. Diagnosis and treatment of hand-arm vibration syndrome and its relationship to carpal tunnel syndrome.

    PubMed

    Falkiner, Sonja

    2003-07-01

    Hand-arm vibration syndrome (HAVS) is a condition associated with the use of vibrating tools that occurs mainly in men. It consists primarily of 'occupational' Raynaud disease and digital polyneuropathy. Carpal tunnel syndrome (CTS) is also associated with hand transmitted vibration exposure and can coexist with HAVS. This article examines recent papers on causation, diagnosis, relationship to CTS and treatment. A Medline search was conducted, as was a search of UK, USA and Australian government occupational health and safety websites. Published papers that were single case studies or of poor design were not included. There are no 'gold standard' diagnostic tests for HAVS. It can mimic CTS in temperate climates and can occur with CTS. This is the diagnostic challenge when a male worker presents with apparent CTS symptoms. If he has worked with vibrating tools for many years, a diagnosis of HAVS or co-diagnosis of HAVS should be considered before a diagnosis of pure CTS is made. Nonwork risk factors for HAVS are predisposition, smoking, and exposure to vibration outside work. Cessation of exposure (and smoking) and redeployment is a critical part of treatment due to the dose response relationship of HAVS. This contrasts with adequately treated CTS, where the vast majority of workers can return to pre-injury duties. In severe cases, calcium antagonists are also used, but treatment is often ineffective. Few workplaces in Australia manage vibration risk or conduct screening to identify workers with early HAVS who should be redeployed. Local doctors have an important opportunity to diagnose HAVS and to make recommendations to the workplace on redeployment as part of treatment before symptoms become irreversible.

  7. A GIS-based approach for the screening assessment of noise and vibration impacts from transit projects.

    PubMed

    Hamed, Maged; Effat, Waleed

    2007-08-01

    Urban transportation projects are essential in increasing the efficiency of moving people and goods within a city, and between cities. Environmental impacts from such projects must be evaluated and mitigated, as applicable. Spatial modeling is a valuable tool for quantifying the potential level of environmental consequences within the context of an environmental impact assessment (EIA) study. This paper presents a GIS-based tool for the assessment of airborne-noise and ground-borne vibration from public transit systems, and its application to an actual project. The tool is based on the US Federal Transit Administration's (FTA) approach, and incorporates spatial information, satellite imaging, geostatistical modeling, and software programming. The tool is applied on a case study of initial environmental evaluation of a light rail transit project in an urban city in the Middle East, to evaluate alternative layouts. The tool readily allowed the alternative evaluation and the results were used as input to a multi-criteria analytic framework.

  8. Explicit Pharmacokinetic Modeling: Tools for Documentation, Verification, and Portability

    EPA Science Inventory

    Quantitative estimates of tissue dosimetry of environmental chemicals due to multiple exposure pathways require the use of complex mathematical models, such as physiologically-based pharmacokinetic (PBPK) models. The process of translating the abstract mathematics of a PBPK mode...

  9. Implementation of a Portable Personal EKG Signal Monitoring System

    NASA Astrophysics Data System (ADS)

    Tan, Tan-Hsu; Chang, Ching-Su; Chen, Yung-Fu; Lee, Cheng

    This research develops a portable personal EKG signal monitoring system to help patients monitor their EKG signals instantly to avoid the occurrence of tragedies. This system is built with two main units: signal pro-cessing unit and monitoring and evaluation unit. The first unit consists of EKG signal sensor, signal amplifier, digitalization circuit, and related control circuits. The second unit is a software tool developed on an embedded Linux platform (called CSA). Experimental result indicates that the proposed system has the practical potential for users in health monitoring. It is demonstrated to be more convenient and with greater portability than the conventional PC-based EKG signal monitoring systems. Furthermore, all the application units embedded in the system are built with open source codes, no licensed fee is required for operating systems and authorized applications. Thus, the building cost is much lower than the traditional systems.

  10. [Determination of acidity and vitamin C in apples using portable NIR analyzer].

    PubMed

    Yang, Fan; Li, Ya-Ting; Gu, Xuan; Ma, Jiang; Fan, Xing; Wang, Xiao-Xuan; Zhang, Zhuo-Yong

    2011-09-01

    Near infrared (NIR) spectroscopy technology based on a portable NIR analyzer, combined with kernel Isomap algorithm and generalized regression neural network (GRNN) has been applied to establishing quantitative models for prediction of acidity and vitamin C in six kinds of apple samples. The obtained results demonstrated that the fitting and the predictive accuracy of the models with kernel Isomap algorithm were satisfactory. The correlation between actual and predicted values of calibration samples (R(c)) obtained by the acidity model was 0.999 4, and for prediction samples (R(p)) was 0.979 9. The root mean square error of prediction set (RMSEP) was 0.055 8. For the vitamin C model, R(c) was 0.989 1, R(p) was 0.927 2, and RMSEP was 4.043 1. Results proved that the portable NIR analyzer can be a feasible tool for the determination of acidity and vitamin C in apples.

  11. Warfighter Integrated Physical Ergonomics Tool Development: Needs Analysis and State of the Art Review

    DTIC Science & Technology

    2011-03-01

    Humansystems® Warfighter Integrated Physical Ergonomics Tool Development Page 14 e) Forces: Griffon seat design assessments include questions of vibration...the suitability of alternative designs . Humansystems® Warfighter Integrated Physical Ergonomics Tool Development Page 5 e) Performance Measures...configurations to assess Humansystems® Warfighter Integrated Physical Ergonomics Tool Development Page 8 design and acquisition decisions, and more

  12. A bi-axial active boring tool for chatter mitigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Redmond, J.M.; Barney, P.S.

    This paper summarizes results of metal cutting tests using an actively damped boring bar to suppress regenerative chatter. PZT stack actuators were integrated into a commercially available two-inch diameter boring bar to suppress bending vibrations. Since the modified tool requires no specialized mounting hardware, it can be readily mounted on a variety of machines. A cutting test using the prototype bar to remove metal from a hardened steel workpiece verifies that the authors actively damped tool yields significant vibration reduction and improved surface finish as compared to the open-loop case. In addition, the overall performance of the prototype bar ismore » compared to that of an unmodified bar of pristine geometry, revealing that a significant enlargement of the stable machining envelope is obtained through application of feedback control.« less

  13. Vibration for Pain Reduction in a Plastic Surgery Clinic.

    PubMed

    Eichhorn, Mitchell George; Karadsheh, Murad Jehad; Krebiehl, Johanna Ruth; Ford, Dawn Marie; Ford, Ronald D

    2016-01-01

    Patients can experience significant pain during routine procedures in the plastic surgery clinic. Methods for clinical pain reduction are often impractical, time-consuming, or ineffective. Vibration is a safe, inexpensive, and highly applicable modality for pain reduction that can be readily utilized for a wide variety of procedures. This study evaluated the use of vibration as a viable pain-reduction strategy in the clinical plastic surgery setting. Patients requiring at least 2 consecutive procedures that are considered painful were enrolled in the study. These included injections, staple removal, and suture removal. In the same patient, one half of the procedures were performed without vibration and the other half with vibration. After completing the procedures, the patients rated their pain with vibration and without vibration. The patient and the researcher also described the experience with a short questionnaire. Twenty-eight patients were enrolled in the study. Patients reported significantly less pain on the Numeric Rating Scale pain scale when vibration was used compared with the control group (p < .001). The average pain score was 3.46 without vibration and 1.93 with vibration, and vibration with injections resulted in the greatest improvement. Eighty-six percent of the patients claimed that vibration significantly reduced their pain. Vibration is an effective method of pain reduction. It significantly reduces the pain experienced by patients during minor office procedures. Given its practicality and ease of use, it is a welcome tool in the plastic surgery clinic.

  14. Accelerometer method and apparatus for integral display and control functions

    NASA Astrophysics Data System (ADS)

    Bozeman, Richard J., Jr.

    1992-06-01

    Vibration analysis has been used for years to provide a determination of the proper functioning of different types of machinery, including rotating machinery and rocket engines. A determination of a malfunction, if detected at a relatively early stage in its development, will allow changes in operating mode or a sequenced shutdown of the machinery prior to a total failure. Such preventative measures result in less extensive and/or less expensive repairs, and can also prevent a sometimes catastrophic failure of equipment. Standard vibration analyzers are generally rather complex, expensive, and of limited portability. They also usually result in displays and controls being located remotely from the machinery being monitored. Consequently, a need exists for improvements in accelerometer electronic display and control functions which are more suitable for operation directly on machines and which are not so expensive and complex. The invention includes methods and apparatus for detecting mechanical vibrations and outputting a signal in response thereto. The apparatus includes an accelerometer package having integral display and control functions. The accelerometer package is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine condition over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase over the selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated. The benefits of a vibration recording and monitoring system with controls and displays readily mountable on the machinery being monitored and having capabilities described will be appreciated by those working in the art.

  15. Accelerometer method and apparatus for integral display and control functions

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1992-01-01

    Vibration analysis has been used for years to provide a determination of the proper functioning of different types of machinery, including rotating machinery and rocket engines. A determination of a malfunction, if detected at a relatively early stage in its development, will allow changes in operating mode or a sequenced shutdown of the machinery prior to a total failure. Such preventative measures result in less extensive and/or less expensive repairs, and can also prevent a sometimes catastrophic failure of equipment. Standard vibration analyzers are generally rather complex, expensive, and of limited portability. They also usually result in displays and controls being located remotely from the machinery being monitored. Consequently, a need exists for improvements in accelerometer electronic display and control functions which are more suitable for operation directly on machines and which are not so expensive and complex. The invention includes methods and apparatus for detecting mechanical vibrations and outputting a signal in response thereto. The apparatus includes an accelerometer package having integral display and control functions. The accelerometer package is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine condition over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase over the selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated. The benefits of a vibration recording and monitoring system with controls and displays readily mountable on the machinery being monitored and having capabilities described will be appreciated by those working in the art.

  16. Thermal and vibration dynamic analysis of an induction motor using optical fiber Bragg gratings

    NASA Astrophysics Data System (ADS)

    Sousa, Kleiton d. M.; Dreyer, Uilian J.; Martelli, Cicero; Cardozo da Silva, Jean Carlos

    2015-09-01

    In this paper it is presented the results of temperature and vibration measurements in a Three-phase Induction Motor (TIM) running at no-load condition. Vibration and temperature analysis are the most successful techniques used for condition monitoring of induction motors. The vibration is measured using two FBGs installed inside of the motor between two subsequent stator teeth. The motor spectrum of vibration when power is at 60 Hz presents the frequencies 60 Hz, 120 Hz, 180 Hz, and 240 Hz as theoretically expected. For the temperature measurement two FBGs are encapsulated in an alumina tube fixed along the stator. The results show 0.9°C difference between the two FBG caused by the motor ventilation nearer of one FBG. These measurements can be used to determine TIM parameters and still be predictive maintenance tool.

  17. The study on dynamic properties of monolithic ball end mills with various slenderness

    NASA Astrophysics Data System (ADS)

    Wojciechowski, Szymon; Tabaszewski, Maciej; Krolczyk, Grzegorz M.; Maruda, Radosław W.

    2017-10-01

    The reliable determination of modal mass, damping and stiffness coefficient (modal parameters) for the particular machine-toolholder-tool system is essential for the accurate estimation of vibrations, stability and thus the machined surface finish formed during the milling process. Therefore, this paper focuses on the analysis of ball end mill's dynamical properties. The tools investigated during this study are monolithic ball end mills with different slenderness values, made of coated cemented carbide. These kinds of tools are very often applied during the precise milling of curvilinear surfaces. The research program included the impulse test carried out for the investigated tools clamped in the hydraulic toolholder. The obtained modal parameters were further applied in the developed tool's instantaneous deflection model, in order to estimate the tool's working part vibrations during precise milling. The application of the proposed dynamics model involved also the determination of instantaneous cutting forces on the basis of the mechanistic approach. The research revealed that ball end mill's slenderness can be considered as an important milling dynamics and machined surface quality indicator.

  18. NRL Radar Division C++ Coding Standard

    DTIC Science & Technology

    2016-12-05

    The coding standard provides tools aimed at helping C++ programmers develop programs that are free of common types of errors, maintainable by...different programmers , portable to other operating systems, easy to read and understand, and have a consistent style. Questions of design, such as how to...mandatory for any organization with quality goals. The purpose of this standard is to provide tools aimed at helping C++ programmers develop programs that

  19. Development of method for quantifying essential tremor using a small optical device.

    PubMed

    Chen, Kai-Hsiang; Lin, Po-Chieh; Chen, Yu-Jung; Yang, Bing-Shiang; Lin, Chin-Hsien

    2016-06-15

    Clinical assessment scales are the most common means used by physicians to assess tremor severity. Some scientific tools that may be able to replace these scales to objectively assess the severity, such as accelerometers, digital tablets, electromyography (EMG) measurement devices, and motion capture cameras, are currently available. However, most of the operational modes of these tools are relatively complex or are only able to capture part of the clinical information; furthermore, using these tools is sometimes time consuming. Currently, there is no tool available for automatically quantifying tremor severity in clinical environments. We aimed to develop a rapid, objective, and quantitative system for measuring the severity of finger tremor using a small portable optical device (Leap Motion). A single test took 15s to conduct, and three algorithms were proposed to quantify the severity of finger tremor. The system was tested with four patients diagnosed with essential tremor. The proposed algorithms were able to quantify different characteristics of tremor in clinical environments, and could be used as references for future clinical assessments. A portable, easy-to-use, small-sized, and noncontact device (Leap Motion) was used to clinically detect and record finger movement, and three algorithms were proposed to describe tremor amplitudes. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Reliability of a Malay-translated questionnaire for use in a hand-arm vibration syndrome study in Malaysia.

    PubMed

    Su, T A; Hoe, V C W

    2008-12-01

    Validity and reliability of the information relating to hand-transmitted vibration exposure and vibration-related health outcome are very important for case finding in hand-arm vibration syndrome (HAVS) studies. In a local HAVS study among a group of construction workers in Kuala Lumpur, Malaysia, a questionnaire translated into Malay was created based on the Hand-transmitted Vibration Health Surveillance--Initial Questionnaire and Clinical Assessment, from Vibration Injury Network. This study was conducted to determine the reliability of standardised questions in the questionnaire used in the study. 15 subjects were selected randomly from the sampling frame of the HAVS study. Test-retest reliability was conducted on all items contained in parts 1-6 of the questionnaire and clinical assessment form, with an interval of 13-14 days between the first and second administration. Kappa coefficient and percentage agreement were calculated for all standardised questions. The kappa coefficient and percentage agreement for all standardised questions varied from -0.174 to 1.000 and 66.7 to 100.0 percent, respectively. The kappa coefficient for important questions related to current vibratory tool usage, tingling, numbness and hand grip weakness were 0.714, 0.432, -0.077 and -0.120, respectively, while the percentage agreement for current vibratory tool usage, finger colour change, tingling, numbness and hand grip weakness were 85.7 percent, 92.8 percent, 79.5 percent, 85.7 percent and 71.4 percent, respectively. Intra-rater reliability on the extent of vibration exposure was good, with the intra-class correlation coefficient (95 percent confidence interval) ranging from 0.786 (0.334-0.931) to 0.975 (0.923-0.992). Critical questions on vascular, neurological and musculoskeletal symptoms of HAVS were found to be reliable. The history on the extent of vibration exposure revealed good reliability when explored by the investigator alone. This questionnaire is considered reliable to be used in the study of HAVS among construction workers working in a construction site.

  1. Air-Microfluidics: Creating Small, Low-cost, Portable Air Quality Sensors

    EPA Science Inventory

    Air-microfluidics shows great promise in dramatically reducing the size, cost, and power requirements of future air quality sensors without compromising their accuracy. Microfabrication provides a suite of relatively new tools for the development of micro electro mechanical syste...

  2. NASA Tech Briefs, November 2007

    NASA Technical Reports Server (NTRS)

    2007-01-01

    Topics include: Wireless Measurement of Contact and Motion Between Contact Surfaces; Wireless Measurement of Rotation and Displacement Rate; Portable Microleak-Detection System; Free-to-Roll Testing of Airplane Models in Wind Tunnels; Cryogenic Shrouds for Testing Thermal-Insulation Panels; Optoelectronic System Measures Distances to Multiple Targets; Tachometers Derived From a Brushless DC Motor; Algorithm-Based Fault Tolerance for Numerical Subroutines; Computational Support for Technology- Investment Decisions; DSN Resource Scheduling; Distributed Operations Planning; Phase-Oriented Gear Systems; Freeze Tape Casting of Functionally Graded Porous Ceramics; Electrophoretic Deposition on Porous Non- Conductors; Two Devices for Removing Sludge From Bioreactor Wastewater; Portable Unit for Metabolic Analysis; Flash Diffusivity Technique Applied to Individual Fibers; System for Thermal Imaging of Hot Moving Objects; Large Solar-Rejection Filter; Improved Readout Scheme for SQUID-Based Thermometry; Error Rates and Channel Capacities in Multipulse PPM; Two Mathematical Models of Nonlinear Vibrations; Simpler Adaptive Selection of Golomb Power-of- Two Codes; VCO PLL Frequency Synthesizers for Spacecraft Transponders; Wide Tuning Capability for Spacecraft Transponders; Adaptive Deadband Synchronization for a Spacecraft Formation; Analysis of Performance of Stereoscopic-Vision Software; Estimating the Inertia Matrix of a Spacecraft; Spatial Coverage Planning for Exploration Robots; and Increasing the Life of a Xenon-Ion Spacecraft Thruster.

  3. Assessment of Occupational Exposure to Manganese and Other Metals in Welding Fumes by Portable X-ray Fluorescence Spectrometer

    PubMed Central

    Laohaudomchok, Wisanti; Cavallari, Jennifer M.; Fang, Shona C.; Lin, Xihong; Herrick, Robert F.; Christiani, David C.; Weisskopf, Marc G.

    2011-01-01

    Elemental analysis of welding fume samples can be done using several laboratory-based techniques. However, portable measurement techniques could offer several advantages. In this study, we sought to determine whether the portable X-ray fluorescence spectrometer (XRF) is suitable for analysis of five metals (manganese, iron, zinc, copper, and chromium) on 37-mm polytetrafluoroethylene filters. Using this filter fitted on a cyclone in line with a personal pump, gravimetric samples were collected from a group of boilermakers exposed to welding fumes. We assessed the assumption of uniform deposition of these metals on the filters, and the relationships between measurement results of each metal obtained from traditional laboratory-based XRF and the portable XRF. For all five metals of interest, repeated measurements with the portable XRF at the same filter area showed good consistency (reliability ratios are equal or close to 1.0 for almost all metals). The portable XRF readings taken from three different areas of each filter were not significantly different (p-values = 0.77 to 0.98). This suggested that the metal rich PM2.5 deposits uniformly on the samples collected using this gravimetric method. For comparison of the two XRFs, the results from the portable XRF were well correlated and highly predictive of those from the laboratory XRF. The Spearman correlation coefficients were from 0.325 for chromium, to 0.995 for manganese and 0.998 for iron. The mean differences as a percent of the mean laboratory XRF readings were also small (<5%) for manganese, iron, and copper. The differences were greater for zinc and chromium, which were present at very low amounts in our samples and below the limits of detection of the portable XRF for many of the samples. These five metals were moderately to strongly correlated with the total fine particle fraction on filters (Spearman ρ = 0.41 for zinc to 0.97 for iron). Such strong correlations and comparable results suggested that the portable XRF could be used as an effective and reliable tool for exposure assessment in many studies. PMID:20526948

  4. Assessment of occupational exposure to manganese and other metals in welding fumes by portable X-ray fluorescence spectrometer.

    PubMed

    Laohaudomchok, Wisanti; Cavallari, Jennifer M; Fang, Shona C; Lin, Xihong; Herrick, Robert F; Christiani, David C; Weisskopf, Marc G

    2010-08-01

    Elemental analysis of welding fume samples can be done using several laboratory-based techniques. However, portable measurement techniques could offer several advantages. In this study, we sought to determine whether the portable X-ray fluorescence spectrometer (XRF) is suitable for analysis of five metals (manganese, iron, zinc, copper, and chromium) on 37-mm polytetrafluoroethylene filters. Using this filter fitted on a cyclone in line with a personal pump, gravimetric samples were collected from a group of boilermakers exposed to welding fumes. We assessed the assumption of uniform deposition of these metals on the filters, and the relationships between measurement results of each metal obtained from traditional laboratory-based XRF and the portable XRF. For all five metals of interest, repeated measurements with the portable XRF at the same filter area showed good consistency (reliability ratios are equal or close to 1.0 for almost all metals). The portable XRF readings taken from three different areas of each filter were not significantly different (p-values = 0.77 to 0.98). This suggested that the metal rich PM(2.5) deposits uniformly on the samples collected using this gravimetric method. For comparison of the two XRFs, the results from the portable XRF were well correlated and highly predictive of those from the laboratory XRF. The Spearman correlation coefficients were from 0.325 for chromium, to 0.995 for manganese and 0.998 for iron. The mean differences as a percent of the mean laboratory XRF readings were also small (<5%) for manganese, iron, and copper. The differences were greater for zinc and chromium, which were present at very low amounts in our samples and below the limits of detection of the portable XRF for many of the samples. These five metals were moderately to strongly correlated with the total fine particle fraction on filters (Spearman rho = 0.41 for zinc to 0.97 for iron). Such strong correlations and comparable results suggested that the portable XRF could be used as an effective and reliable tool for exposure assessment in many studies.

  5. Light guide technology: using light to enhance safety

    NASA Astrophysics Data System (ADS)

    Lerner, William S.

    2009-05-01

    When used to detect extreme temperatures in harsh environments, warning devices have been placed at a distance from the "danger zone" for several reasons. The inability to mix electricity with flammable, caustic, liquid or volatile substances, the limited heat tolerances exhibited by most light sources, and the susceptibility of light sources to damage from vibration, have made the placement of a warning light directly within these harsh environments impossible. This paper describes a system that utilizes a beam of light to provide just such a warning. This system can be used with hard-wired or wireless sensors, side-light illumination, image projection and image transfer. The entire system may be self-contained and portable.

  6. Preliminary Design and Evaluation of Portable Electronic Flight Progress Strips

    NASA Technical Reports Server (NTRS)

    Doble, Nathan A.; Hansman, R. John

    2002-01-01

    There has been growing interest in using electronic alternatives to the paper Flight Progress Strip (FPS) for air traffic control. However, most research has been centered on radar-based control environments, and has not considered the unique operational needs of the airport air traffic control tower. Based on an analysis of the human factors issues for control tower Decision Support Tool (DST) interfaces, a requirement has been identified for an interaction mechanism which replicates the advantages of the paper FPS (e.g., head-up operation, portability) but also enables input and output with DSTs. An approach has been developed which uses a Portable Electronic FPS that has attributes of both a paper strip and an electronic strip. The prototype flight strip system uses Personal Digital Assistants (PDAs) to replace individual paper strips in addition to a central management interface which is displayed on a desktop computer. Each PDA is connected to the management interface via a wireless local area network. The Portable Electronic FPSs replicate the core functionality of paper flight strips and have additional features which provide a heads-up interface to a DST. A departure DST is used as a motivating example. The central management interface is used for aircraft scheduling and sequencing and provides an overview of airport departure operations. This paper will present the design of the Portable Electronic FPS system as well as preliminary evaluation results.

  7. Piezoelectric self-sensing actuator for active vibration control of motorized spindle based on adaptive signal separation

    NASA Astrophysics Data System (ADS)

    He, Ye; Chen, Xiaoan; Liu, Zhi; Qin, Yi

    2018-06-01

    The motorized spindle is the core component of CNC machine tools, and the vibration of it reduces the machining precision and service life of the machine tools. Owing to the fast response, large output force, and displacement of the piezoelectric stack, it is often used as the actuator in the active vibration control of the spindle. A piezoelectric self-sensing actuator (SSA) can reduce the cost of the active vibration control system and simplify the structure by eliminating the use of a sensor, because a SSA can have both actuating and sensing functions at the same time. The signal separation method of a SSA based on a bridge circuit is widely applied because of its simple principle and easy implementation. However, it is difficult to maintain dynamic balance of the circuit. Prior research has used adaptive algorithm to balance of the bridge circuit on the flexible beam dynamically, but those algorithms need no correlation between sensing and control voltage, which limit the applications of SSA in the vibration control of the rotor-bearing system. Here, the electromechanical coupling model of the piezoelectric stack is established, followed by establishment of the dynamic model of the spindle system. Next, a new adaptive signal separation method based on the bridge circuit is proposed, which can separate relative small sensing voltage from related mixed voltage adaptively. The experimental results show that when the self-sensing signal obtained from the proposed method is used as a displacement signal, the vibration of the motorized spindle can be suppressed effectively through a linear quadratic Gaussian (LQG) algorithm.

  8. Multiphonon: Phonon Density of States tools for Inelastic Neutron Scattering Powder Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Y. Y. Lin, Jiao; Islam, Fahima; Kresh, Max

    The multiphonon python package calculates phonon density of states, a reduced representation of vibrational property of condensed matter (see, for example, Section “Density of Normal Modes” in Chapter 23 “Quantum Theory of the Harmonic Crystal” of (Ashcroft and Mermin 2011)), from inelastic neutron scattering (see, for example (B. Fultz et al. 2006–2016)) spectrum from a powder sample. Inelastic neutron spectroscopy (INS) is a probe of excitations in solids of vibrational or magnetic origins. In INS, neutrons can lose(gain) energy to(from) the solid in the form of quantized lattice vibrations – phonons. Measuring phonon density of states is usually the firstmore » step in determining the phonon properties of a material experimentally. Phonons play a very important role in understanding the physical properties of a solid, including thermal conductivity and electrical conductivity. Hence, INS is an important tool for studying thermoelectric materials (Budai et al. 2014, Li et al. (2015)), where low thermal conductivity and high electrical conductivity are desired. Study of phonon entropy also made important contributions to the research of thermal dynamics and phase stability of materials (B. Fultz 2010, bogdanoff2002phonon, swan2006vibrational).« less

  9. Spatial resonance in a small artery excited by vibration input as a possible mechanism to cause hand-arm vascular disorders

    NASA Astrophysics Data System (ADS)

    Pattnaik, Shrikant; Banerjee, Rupak; Kim, Jay

    2012-04-01

    Hand-arm vibration syndrome (HAVS) is collectively a vasospastic and neurodegenerative occupational disease. One of the major symptoms of HAVS is vibration white finger (VWF) caused by exaggerated vasoconstriction of the arteries and skin arterioles. While VWF is a very painful and costly occupational illness, its pathology has not been well understood. In this study a small artery is modeled as a fluid filled elastic tube whose diameter changes along the axial direction. Equations of motion are developed by considering interactions between the fluid, artery wall and soft-tissue bed. It is shown that the resulting wave equation is the same as that of the basilar membrane in the cochlea of mammals. Therefore, the artery system shows a spatial resonance as in the basilar membrane, which responds with the highest amplitude at the location determined by the vibration frequency. This implies that a long-term use of one type of tool will induce high-level stresses at a few identical locations of the artery that correspond to the major frequency components of the tool. Hardening and deterioration of the artery at these locations may be a possible cause of VWF.

  10. Multiphonon: Phonon Density of States tools for Inelastic Neutron Scattering Powder Data

    DOE PAGES

    Y. Y. Lin, Jiao; Islam, Fahima; Kresh, Max

    2018-01-29

    The multiphonon python package calculates phonon density of states, a reduced representation of vibrational property of condensed matter (see, for example, Section “Density of Normal Modes” in Chapter 23 “Quantum Theory of the Harmonic Crystal” of (Ashcroft and Mermin 2011)), from inelastic neutron scattering (see, for example (B. Fultz et al. 2006–2016)) spectrum from a powder sample. Inelastic neutron spectroscopy (INS) is a probe of excitations in solids of vibrational or magnetic origins. In INS, neutrons can lose(gain) energy to(from) the solid in the form of quantized lattice vibrations – phonons. Measuring phonon density of states is usually the firstmore » step in determining the phonon properties of a material experimentally. Phonons play a very important role in understanding the physical properties of a solid, including thermal conductivity and electrical conductivity. Hence, INS is an important tool for studying thermoelectric materials (Budai et al. 2014, Li et al. (2015)), where low thermal conductivity and high electrical conductivity are desired. Study of phonon entropy also made important contributions to the research of thermal dynamics and phase stability of materials (B. Fultz 2010, bogdanoff2002phonon, swan2006vibrational).« less

  11. Surgical resident evaluations of portable laparoscopic box trainers incorporated into a simulation-based minimally invasive surgery curriculum.

    PubMed

    Zapf, Matthew A C; Ujiki, Michael B

    2015-02-01

    Box trainers have been shown to be an effective tool for teaching laparoscopic skills; however, residents are challenged to find practice time. Portable trainers theoretically allow for extended hands on practice out of the hospital. We aimed to report resident experience with laparoscopic home box trainers. Over 2 years, all residents rotating through a minimally invasive service were given a portable trainer and access to a surgical simulation lab for practice. Each trainer contained a collapsible frame, a webcam with USB port, trocars, and laparoscopic instruments (needle driver, shears, Maryland and straight dissecting graspers) as well as Fundamentals of Laparoscopic Surgery skills testing materials. Residents were asked to log hours, usages, and their experience anonymously. Twenty-three residents received a portable trainer. Fifty percent of the participants found the trainer useful or very useful, 25% said it was not useful, and 25% did not access the trainer. Those that used the trainer during their rotation did so 3.1 ± 3.0 times for 2.9 ± 3.0 hours/week. After completing their rotation, 5 of 12 residents used their trainer for an average of 10.2 ± 9.4 hours. Forty-two percent of the responders liked the accessibility of the home box trainers, while 25% criticized the camera-computer interface. Portable box trainers are useful and can effectively supplement a laboratory-based surgical simulation curriculum; however, personal possession of a portable simulator does not result in voluntarily long-term practice. © The Author(s) 2014.

  12. Sensing site-specific structural characteristics and chirality using vibrational circular dichroism of isotope labeled peptides.

    PubMed

    Keiderling, Timothy A

    2017-12-01

    Isotope labeling has a long history in chemistry as a tool for probing structure, offering enhanced sensitivity, or enabling site selection with a wide range of spectroscopic tools. Chirality sensitive methods such as electronic circular dichroism are global structural tools and have intrinsically low resolution. Consequently, they are generally insensitive to modifications to enhance site selectivity. The use of isotope labeling to modify vibrational spectra with unique resolvable frequency shifts can provide useful site-specific sensitivity, and these methods have been recently more widely expanded in biopolymer studies. While the spectral shifts resulting from changes in isotopic mass can provide resolution of modes from specific parts of the molecule and can allow detection of local change in structure with perturbation, these shifts alone do not directly indicate structure or chirality. With vibrational circular dichroism (VCD), the shifted bands and their resultant sign patterns can be used to indicate local conformations in labeled biopolymers, particularly if multiple labels are used and if their coupling is theoretically modeled. This mini-review discusses selected examples of the use of labeling specific amides in peptides to develop local structural insight with VCD spectra. © 2017 Wiley Periodicals, Inc.

  13. The study on hand-arm vibration syndrome in China.

    PubMed

    Lin, Wang; Chunzhi, Zhang; Qiang, Zhang; Kai, Zhang; Xiaoli, Zeng

    2005-07-01

    To review the main achievement and problems of study on hand-arm vibration syndrome in China. The epidemiological and clinical study indicate that HAVS was reported from almost provinces in China, the prevalence of VWF ranges from 2.5% to 82.8% in the workers with vibrating tool use. The exposure-response relationship between prevalence of VWF and intensity and duration of exposed to hand-transmitted vibration has confirmed. Diagnostic criteria of HAVS has been established and performed by Chinese government in 1985, and it was revised by government as a national standard for occupational health in 2002. The "hygienic standard for hand-transmitted vibration in workplace" as a national standard and the "methods of measurement and assessment for hand-transmitted vibration" as a recommend standard were published by government also. The limited value of exposed to hand-arm vibration was 5.0 m/s2 that is energy equivalent frequency-weighted acceleration for a period of 4 h (ahw(4)). There are some problems in this field of China need to further study in the future.

  14. Vibrational Dynamics of Biological Molecules: Multi-quantum Contributions

    PubMed Central

    Leu, Bogdan M.; Timothy Sage, J.; Zgierski, Marek Z.; Wyllie, Graeme R. A.; Ellison, Mary K.; Robert Scheidt, W.; Sturhahn, Wolfgang; Ercan Alp, E.; Durbin, Stephen M.

    2006-01-01

    High-resolution X-ray measurements near a nuclear resonance reveal the complete vibrational spectrum of the probe nucleus. Because of this, nuclear resonance vibrational spectroscopy (NRVS) is a uniquely quantitative probe of the vibrational dynamics of reactive iron sites in proteins and other complex molecules. Our measurements of vibrational fundamentals have revealed both frequencies and amplitudes of 57Fe vibrations in proteins and model compounds. Information on the direction of Fe motion has also been obtained from measurements on oriented single crystals, and provides an essential test of normal mode predictions. Here, we report the observation of weaker two-quantum vibrational excitations (overtones and combinations) for compounds that mimic the active site of heme proteins. The predicted intensities depend strongly on the direction of Fe motion. We compare the observed features with predictions based on the observed fundamentals, using information on the direction of Fe motion obtained either from DFT predictions or from single crystal measurements. Two-quantum excitations may become a useful tool to identify the directions of the Fe oscillations when single crystals are not available. PMID:16894397

  15. Vibrational Action Spectroscopy of Solids: New Surface-Sensitive Technique

    NASA Astrophysics Data System (ADS)

    Wu, Zongfang; Płucienik, Agata; Feiten, Felix E.; Naschitzki, Matthias; Wachsmann, Walter; Gewinner, Sandy; Schöllkopf, Wieland; Staemmler, Volker; Kuhlenbeck, Helmut; Freund, Hans-Joachim

    2017-09-01

    Vibrational action spectroscopy employing infrared radiation from a free-electron laser has been successfully used for many years to study the vibrational and structural properties of gas phase aggregates. Despite the high sensitivity of this method no relevant studies have yet been conducted for solid sample surfaces. We have set up an experiment for the application of this method to such targets, using infrared light from the free-electron laser of the Fritz Haber Institute. In this Letter, we present first results of this technique with adsorbed argon and neon atoms as messengers. We were able to detect surface-located vibrations of a thin V2O3(0 0 0 1 ) film on Au(111) as well as adsorbate vibrations, demonstrating that this method is highly surface sensitive. We consider that the dominant channel for desorption of the messenger atoms is direct inharmonic vibrational coupling, which is essentially insensitive to subsurface or bulk vibrations. Another channel is thermal desorption due to sample heating by absorption of infrared light. The high surface sensitivity of the nonthermal channel and its insensitivity to subsurface modes makes this technique an ideal tool for the study of surface-located vibrations.

  16. Vibrational Action Spectroscopy of Solids: New Surface-Sensitive Technique.

    PubMed

    Wu, Zongfang; Płucienik, Agata; Feiten, Felix E; Naschitzki, Matthias; Wachsmann, Walter; Gewinner, Sandy; Schöllkopf, Wieland; Staemmler, Volker; Kuhlenbeck, Helmut; Freund, Hans-Joachim

    2017-09-29

    Vibrational action spectroscopy employing infrared radiation from a free-electron laser has been successfully used for many years to study the vibrational and structural properties of gas phase aggregates. Despite the high sensitivity of this method no relevant studies have yet been conducted for solid sample surfaces. We have set up an experiment for the application of this method to such targets, using infrared light from the free-electron laser of the Fritz Haber Institute. In this Letter, we present first results of this technique with adsorbed argon and neon atoms as messengers. We were able to detect surface-located vibrations of a thin V_{2}O_{3}(0001) film on Au(111) as well as adsorbate vibrations, demonstrating that this method is highly surface sensitive. We consider that the dominant channel for desorption of the messenger atoms is direct inharmonic vibrational coupling, which is essentially insensitive to subsurface or bulk vibrations. Another channel is thermal desorption due to sample heating by absorption of infrared light. The high surface sensitivity of the nonthermal channel and its insensitivity to subsurface modes makes this technique an ideal tool for the study of surface-located vibrations.

  17. Vibration safety limits for magnetic resonance elastography.

    PubMed

    Ehman, E C; Rossman, P J; Kruse, S A; Sahakian, A V; Glaser, K J

    2008-02-21

    Magnetic resonance elastography (MRE) has been demonstrated to have potential as a clinical tool for assessing the stiffness of tissue in vivo. An essential step in MRE is the generation of acoustic mechanical waves within a tissue via a coupled mechanical driver. Motivated by an increasing volume of human imaging trials using MRE, the objectives of this study were to audit the vibration amplitude of exposure for our IRB-approved human MRE studies, to compare these values to a conservative regulatory standard for vibrational exposure and to evaluate the applicability and implications of this standard for MRE. MRE displacement data were examined from 29 MRE exams, including the liver, brain, kidney, breast and skeletal muscle. Vibrational acceleration limits from a European Union directive limiting occupational exposure to whole-body and extremity vibrations (EU 2002/44/EC) were adjusted for time and frequency of exposure, converted to maximum displacement values and compared to the measured in vivo displacements. The results indicate that the vibrational amplitudes used in MRE studies are below the EU whole-body vibration limit, and the EU guidelines represent a useful standard that could be readily accepted by Institutional Review Boards to define standards for vibrational exposures for MRE studies in humans.

  18. Vibration safety limits for magnetic resonance elastography

    PubMed Central

    Ehman, E C; Rossman, P J; Kruse, S A; Sahakian, A V; Glaser, K J

    2010-01-01

    Magnetic resonance elastography (MRE) has been demonstrated to have potential as a clinical tool for assessing the stiffness of tissue in vivo. An essential step in MRE is the generation of acoustic mechanical waves within tissue via a coupled mechanical driver. Motivated by an increasing volume of human imaging trials using MRE, the objectives of this study were to audit the vibration amplitude of exposure for our IRB-approved human MRE studies, to compare these values to a conservative regulatory standard for vibrational exposure, and to evaluate the applicability and implications of this standard for MRE. MRE displacement data were examined from 29 MRE exams, including the liver, brain, kidney, breast, and skeletal muscle. Vibrational acceleration limits from a European Union directive limiting occupational exposure to whole-body and extremity vibrations (EU 2002/44/EC) were adjusted for time and frequency of exposure, converted to maximum displacement values, and compared to the measured in vivo displacements. The results indicate that the vibrational amplitudes used in MRE studies are below the EU whole-body vibration limit and the EU guidelines represent a useful standard that could be readily accepted by Institutional Review Boards to define standards for vibrational exposures for MRE studies in humans. PMID:18263949

  19. Upper-limb tremor suppression with a 7DOF exoskeleton power-assist robot.

    PubMed

    Kiguchi, Kazuo; Hayashi, Yoshiaki

    2013-01-01

    A tremor which is one of the involuntary motions is somewhat rhythmic motion that may occur in various body parts. Although there are several kinds of the tremor, an essential tremor is the most common tremor disorder of the arm. The essential tremor is a disorder of unknown cause, and it is common in the elderly. The essential tremor interferes with a patient's daily living activity, because it may occur during a voluntary motion. If a patient of an essential tremor uses an EMG-based controlled power-assist robot, the robot might misunderstand the user's motion intention because of the effect of the essential tremor. In that case, upper-limb power-assist robots must carry out tremor suppression as well as power-assist, since a person performs various precise tasks with certain tools by the upper-limb in daily living. Therefore, it is important to suppress the tremor at the hand and grasped tool. However, in the case of the tremor suppression control method which suppressed the vibrations of the hand and the tip of the tool, vibration of other part such as elbow might occur. In this paper, the tremor suppression control method for upper-limb power-assist robot is proposed. In the proposed method, the vibration of the elbow is suppressed in addition to the hand and the tip of the tool. The validity of the proposed method was verified by the experiments.

  20. Effects on Vibration and Surface Roughness in High Speed Micro End-Milling of Inconel 718 with Minimum Quantity Lubrication

    NASA Astrophysics Data System (ADS)

    Rahman, Mohamed Abd; Yeakub Ali, Mohammad; Saddam Khairuddin, Amir

    2017-03-01

    This paper presents the study on vibration and surface roughness of Inconel 718 workpiece produced by micro end-milling using Mikrotools Integrated Multi-Process machine tool DT-110 with control parameters; spindle speed (15000 rpm and 30000 rpm), feed rate (2 mm/min and 4 mm/min) and depth of cut (0.10 mm and 0.15mm). The vibration was measured using DYTRAN accelerometer instrument and the average surface roughness Ra was measured using Wyko NT1100. The analysis of variance (ANOVA) by using Design Expert software revealed that feed rate and depth of cut are the most significant factors on vibration meanwhile for average surface roughness, Ra, spindle speed is the most significant factor.

  1. Epidemiologic survey of vibration syndrome among riveters, chippers and grinders in the railroad system of the People's Republic of China.

    PubMed

    Yu, Z S; Chao, H; Qiao, L; Qian, D S; Ye, Y H

    1986-08-01

    Vibration syndrome caused by hand-held vibrating tools in 14 locomotive and rolling stock plants in four regions of the People's Republic of China (south, north, middlewest, and northeast) and the influence of climatic factors on its prevalence rate were studied. For 1,028 male workers (705 riveters, 284 chippers, and 39 grinders), the prevalence rate of the syndrome was 13.4% and for a reference group of 256 workers it was 1.6%. The prevalence rate of white finger in the four regions differed and was higher in northeast and north China than in south and middlewest China. This finding suggests that cold climate and humidity may be causative factors of the vibration syndrome.

  2. Comparison between two portable devices for widefield PpIX fluorescence during cervical intraepithelial neoplasia treatment

    NASA Astrophysics Data System (ADS)

    Carbinatto, Fernanda M.; Inada, Natalia Mayumi; Lombardi, Welington; Cossetin, Natália Fernandez; Varoto, Cinthia; Kurachi, Cristina; Bagnato, Vanderlei Salvador

    2015-06-01

    The use of portable electronic devices, in particular mobile phones such as smartphones is increasing not only for all known applications, but also for diagnosis of diseases and monitoring treatments like topical Photodynamic Therapy. The aim of the study is to evaluate the production of the photosensitizer Protoporphyrin IX (PpIX) after topical application of a cream containing methyl aminolevulinate (MAL) in the cervix with diagnosis of Cervical Intraepithelial Neoplasia (CIN) through the fluorescence images captured after one and three hours and compare the images using two devices (a Sony Xperia® mobile and an Apple Ipod®. Was observed an increasing fluorescence intensity of the cervix three hours after cream application, in both portable electronic devices. However, because was used a specific program for the treatment of images using the Ipod® device, these images presented better resolution than observed by the Sony cell phone without a specific program. One hour after cream application presented a more selective fluorescence than the group of three hours. In conclusion, the use of portable devices to obtain images of PpIX fluorescence shown to be an effective tool and is necessary the improvement of programs for achievement of better results.

  3. 29 CFR 570.34 - Occupations that may be performed by minors 14 and 15 years of age.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... comparative shopping. (e) Price marking and tagging by hand or machine, assembling orders, packing, and... machines shall mean all fixed or portable machines or tools driven by power and used or designed for...

  4. 29 CFR 570.34 - Occupations that may be performed by minors 14 and 15 years of age.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... comparative shopping. (e) Price marking and tagging by hand or machine, assembling orders, packing, and... machines shall mean all fixed or portable machines or tools driven by power and used or designed for...

  5. 29 CFR 570.34 - Occupations that may be performed by minors 14 and 15 years of age.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... comparative shopping. (e) Price marking and tagging by hand or machine, assembling orders, packing, and... machines shall mean all fixed or portable machines or tools driven by power and used or designed for...

  6. 29 CFR 570.34 - Occupations that may be performed by minors 14 and 15 years of age.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... comparative shopping. (e) Price marking and tagging by hand or machine, assembling orders, packing, and... machines shall mean all fixed or portable machines or tools driven by power and used or designed for...

  7. Microsystems Enabled Photovoltaics

    ScienceCinema

    Gupta, Vipin; Nielson, Greg; Okandan, Murat, Granata, Jennifer; Nelson, Jeff; Haney, Mike; Cruz-Campa, Jose Luiz

    2018-06-07

    Sandia's microsystems enabled photovoltaic advances combine mature technology and tools currently used in microsystem production with groundbreaking advances in photovoltaics cell design, decreasing production and system costs while improving energy conversion efficiency. The technology has potential applications in buildings, houses, clothing, portable electronics, vehicles, and other contoured structures.

  8. Miniature 'Wearable' PET Scanner Ready for Use

    ScienceCinema

    Vaska, Paul

    2017-12-27

    Scientists from BNL, Stony Brook University, and collaborators have demonstrated the efficacy of a "wearable" portable PET scanner they've developed for rats. The device will give neuroscientists a new tool for simultaneously studying brain function and behavior in fully awake, moving animals.

  9. Intelligent MEMS spectral sensor for NIR applications (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Kantojärvi, Uula; Antila, Jarkko E.; Mäkynen, Jussi; Suhonen, Janne

    2017-05-01

    Near Infrared (NIR) spectrometers have been widely used in many material inspection applications, but mainly in central laboratories. The role of miniaturization, robustness of spectrometer and portability are really crucial when field inspection tools should be developed. We present an advanced spectral sensor based on a tunable Microelectromechanical (MEMS) Fabry-Perot Interferometer which will meet these requirements. We describe the wireless device design, operation principle and easy-to-use algorithms to adapt the sensor to number of applications. Multiple devices can be operated simultaneously and seamlessly through cloud connectivity. We also present some practical NIR applications carried out with truly portable NIR device.

  10. Using a portable sulfide monitor as a motivational tool: a clinical study.

    PubMed

    Uppal, Ranjit Singh; Malhotra, Ranjan; Grover, Vishakha; Grover, Deepak

    2012-01-01

    Bad breath has a significant impact on daily life of those who suffer from it. Oral malodor may rank only behind dental caries and periodontal disease as the cause of patient's visit to dentist. An aim of this study was to use a portable sulfide monitor as a motivational tool for encouraging the patients towards the better oral hygiene by correlating the plaque scores with sulfide monitor scores, and comparing the sulfide monitor scores before and after complete prophylaxis and 3 months after patient motivation. 30 patients with chronic periodontitis, having chief complaint of oral malodor participated in this study. At first visit, the plaque scores (P1) and sulfide monitor scores before (BCR1) and after complete oral prophylaxis (BCR2) were taken. Then the patients were motivated towards the better oral hygiene. After 3 months, plaque scores (P2) and sulfide monitor scores (BCR3) were recorded again. It was done using SPSS (student package software for statistical analysis). Paired sample test was performed. Statistically significant reduction in sulfide monitor scores was reported after the complete oral prophylaxis and 3 months after patient motivation. Plaque scores were significantly reduced after a period of 3 months. Plaque scores and breathchecker scores were positively correlated. An intensity of the oral malodor was positively correlated with the plaque scores. The portable sulfide monitor was efficacious in motivating the patients towards the better oral hygiene.

  11. The Healthcare Administrator's Associate: an experiment in distributed healthcare information systems.

    PubMed Central

    Fowler, J.; Martin, G.

    1997-01-01

    The Healthcare Administrator's Associate is a collection of portable tools designed to support analysis of data retrieved via the Internet from diverse distributed healthcare information systems by means of the InfoSleuth system of distributed software agents. Development of these tools is part of an effort to enhance access to diverse and geographically distributed healthcare data in order to improve the basis upon which administrative and clinical decisions are made. PMID:9357686

  12. Combination of Ultrasonic Vibration and Cryogenic Cooling for Cutting Performance Improvement of Inconel 718 Turning

    NASA Astrophysics Data System (ADS)

    Lin, S. Y.; Chung, C. T.; Cheng, Y. Y.

    2011-01-01

    The main objective of this study is to develop a thermo-elastic-plastic coupling model, based on a combination skill of ultrasonically assisted cutting and cryogenic cooling, under large deformation for Inconel 718 alloy machining process. The improvement extent on cutting performance and tool life promotion may be examined from this investigation. The critical value of the strain energy density of the workpiece will be utilized as the chip separation and the discontinuous chip segmentation criteria. The forced convection cooling and a hydrodynamic lubrication model will be considered and formulated in the model. Finite element method will be applied to create a complete numerical solution for this ultrasonic vibration cutting model. During the analysis, the cutting tool is incrementally advanced forward with superimposed ultrasonic vibration in a back and forth step-by-step manner, from an incipient stage of tool-workpiece engagement to a steady state of chip formation, a whole simulation of orthogonal cutting process under plane strain deformation is thus undertaken. High shear strength induces a fluctuation phenomenon of shear angle, high shear strain rate, variation of chip types and chip morphology, tool-chip contact length variation, the temperature distributions within the workpiece, chip and tool, periodic fluctuation in cutting forces can be determined from the developed model. A complete comparison of machining characteristics between some different combinations of ultrasonically assisted cutting and cryogenic cooling with conventional cutting operation can be acquired. Finally, the high-speed turning experiment for Inconel 718 alloy will be taken in the laboratory to validate the accuracy of the model, and the progressive flank wear, crater wear, notching and chipping of the tool edge can also be measured in the experiments.

  13. Portable acuity screening for any school: validation of patched HOTV with amblyopic patients and Bangerter normals.

    PubMed

    Tsao Wu, Maya; Armitage, M Diane; Trujillo, Claire; Trujillo, Anna; Arnold, Laura E; Tsao Wu, Lauren; Arnold, Robert W

    2017-12-04

    We needed to validate and calibrate our portable acuity screening tools so amblyopia could be detected quickly and effectively at school entry. Spiral-bound flip cards and download pdf surround HOTV acuity test box with critical lines were combined with a matching card. Amblyopic patients performed critical line, then threshold acuity which was then compared to patched E-ETDRS acuity. 5 normal subjects wore Bangerter foil goggles to simulate blur for comparative validation. The 31 treated amblyopic eyes showed: logMAR HOTV = 0.97(logMAR E-ETDRS)-0.04 r2 = 0.88. All but two (6%) fell less than 2 lines difference. The five showed logMAR HOTV = 1.09 ((logMAR E-ETDRS) + .15 r2 = 0.63. The critical-line, test box was 98% efficient at screening within one line of 20/40. These tools reliably detected acuity in treated amblyopic patients and Bangerter blurred normal subjects. These free and affordable tools provide sensitive screening for amblyopia in children from public, private and home schools. Changing "pass" criteria to 4 out of 5 would improve sensitivity with somewhat slower testing for all students.

  14. Servomotors . (Latest citations from the Aerospace Database)

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The bibliography contains citations concerning the design, testing, and application of servomotors. AC, DC, and brushless motor drives are discussed. Applications are examined, including use in hydraulic presses; teleprinters; machine tools; sewing machines; and servocontrol devices for instrumentation, robots, and aircraft control. Testing methods evaluate precision, vibration and vibration reduction, and stability of servomotors. (Contains 50-250 citations and includes a subject term index and title list.)

  15. Structural coloration of metallic surfaces with micro/nano-structures induced by elliptical vibration texturing

    NASA Astrophysics Data System (ADS)

    Yang, Yang; Pan, Yayue; Guo, Ping

    2017-04-01

    Creating orderly periodic micro/nano-structures on metallic surfaces, or structural coloration, for control of surface apparent color and optical reflectivity has been an exciting research topic over the years. The direct applications of structural coloration include color marking, display devices, and invisibility cloak. This paper presents an efficient method to colorize metallic surfaces with periodic micro/nano-gratings using elliptical vibration texturing. When the tool vibration is coupled with a constant cutting velocity, controlled periodic ripples can be generated due to the overlapping tool trajectory. These periodic ripples with a wavelength near visible spectrum can act as micro-gratings to introduce iridescent colors. The proposed technique also provides a flexible method for color marking of metallic surfaces with arbitrary patterns and images by precise control of the spacing distance and orientation of induced micro/nano-ripples. Theoretical analysis and experimental results are given to demonstrate structural coloration of metals by a direct mechanical machining technique.

  16. A Novel Well Drill Assisted with High-Frequency Vibration Using the Bending Mode

    PubMed Central

    Qi, Xinda; Chen, Weishan; Tang, Xintian; Shi, Shengjun

    2018-01-01

    It is important for companies to increase the efficiency of drilling as well as prolong the lifetime of the drilling tool. Since some previous investigations indicated that a superposition of well drilling with an additional vibration increases the drilling efficiency, this paper introduces a novel well drill which is assisted with additional vibrations by means of piezoelectric sandwich bending vibration transducer. The proposed drill uses bending vibrations in two different directions to from an elliptical trajectory movement, which can help the drill to break the surface of hard material more efficiently and clean away the lithic fragments more easily. The proposed well drill with bending vibration transducer is designed to have a resonance frequency of the first bending vibration mode of about 1779 Hz. The motion equation of the particle on the edge of the drill bit is developed and analyzed. The vibration trajectory of the particle on the edge of the drill bit is calculated by using finite element method. A prototype of the proposed drill using bending vibrations is fabricated and tested to verify the aim of drilling efficiency increase. The feed speed of the vibration assisted drilling is tested to be about 0.296 mm/s when the excitation voltage of the transducer is 300 V, while this speed decreases to about 0.195 mm/s when no vibration is added. This comparison shows that the feed speed of the vibration assisted drilling is about 52% higher than that of the normal drilling, which means the proposed drill has a better efficiency and it is important to consider vibration superimposition in well drilling. In addition, the surface of the drill hole gained by the vibration assisted drilling is smoother than that of the normal drilling, which makes the clearance easier. PMID:29641481

  17. On the Use of Poetry in Medical Education

    ERIC Educational Resources Information Center

    Wellbery, Caroline

    2006-01-01

    Poetry can be a powerful tool in teaching students and residents interpersonal and scientific aspects of clinical medicine. Advantages of using poetry include emotional intensity, succinct, portable formulations and communication of encompassing, "existential" truths. Limitations include learners' lack of familiarity with the medium of…

  18. Carpentry Specialist.

    ERIC Educational Resources Information Center

    Air Force Training Command, Sheppard AFB, TX.

    This instructional package is intended for use in training Air Force personnel enrolled in a program for apprentice carpenters. Training includes an introduction to carpentry and provides instruction in the use of carpentry hand, portable power, and shop tools; construction and maintenance of wood structures; installation of building hardware; and…

  19. Image manipulation software portable on different hardware platforms: what is the cost?

    NASA Astrophysics Data System (ADS)

    Ligier, Yves; Ratib, Osman M.; Funk, Matthieu; Perrier, Rene; Girard, Christian; Logean, Marianne

    1992-07-01

    A hospital wide PACS project is currently under development at the University Hospital of Geneva. The visualization and manipulation of images provided by different imaging modalities constitutes one of the most challenging components of a PACS. Because there are different requirements depending on the clinical usage, it was necessary for such a visualization software to be provided on different types of workstations in different sectors of the PACS. The user interface has to be the same independently of the underlying workstation. Beside, in addition to a standard set of image manipulation and processing tools there is a need for more specific clinical tools that should be easily adapted to specific medical requirements. To achieve operating and windowing systems: the standard Unix/X-11/OSF-Motif based workstations and the Macintosh family and should be easily ported on other systems. This paper describes the design of such a system and discusses the extra cost and efforts involved in the development of a portable and easily expandable software.

  20. Tool enables proper mating of accelerometer and cable connector

    NASA Technical Reports Server (NTRS)

    Steed, C. N.

    1966-01-01

    Tool supports accelerometer in axial alignment with an accelerometer cable connector and permits tightening of the accelerometer to the cable connector with a torque wrench. This is done without damaging the components or permitting them to work loose under sustained, high-level vibrations.

  1. Development of Friction Stir Welding Technologies for In-Space Manufacturing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Longhurst, William R.; Cox, Chase D.; Gibson, Brian T.

    Friction stir welding (FSW) has emerged as an attractive process for fabricating aerospace vehicles. Current FSW state-of-the-art uses large machines that are not portable. However, there is a growing need for fabrication and repair operations associated with in-space manufacturing. This need stems from a desire for prolonged missions and travel beyond low-earth orbit. To address this need, research and development is presented regarding two enabling technologies. The first is a self-adjusting and aligning (SAA) FSW tool that drastically reduces the axial force that has historically been quite large. The SAA-FSW tool is a bobbin style tool that floats freely, withoutmore » any external actuators, along its vertical axis to adjust and align with the workpiece s position and orientation. Successful butt welding of 1/8 in. (3.175 mm) thick aluminum 1100 was achieved in conjunction with a drastic reduction and near elimination of the axial process force. Along with the SAA-FSW, an innovative in-process monitor technique is presented in which a magnetoelastic force rate-of-change sensor is employed. The sensor consists of a magnetized FSW tool that is used to induce a voltage in a coil surrounding the tool when changes to the process forces occur. The sensor was able to detect 1/16 in. (1.5875 mm) diameter voids. It is concluded that these technologies could be applied toward the development of a portable FSW machine for use in space.« less

  2. Development of Friction Stir Welding Technologies for In-Space Manufacturing

    DOE PAGES

    Longhurst, William R.; Cox, Chase D.; Gibson, Brian T.; ...

    2016-08-26

    Friction stir welding (FSW) has emerged as an attractive process for fabricating aerospace vehicles. Current FSW state-of-the-art uses large machines that are not portable. However, there is a growing need for fabrication and repair operations associated with in-space manufacturing. This need stems from a desire for prolonged missions and travel beyond low-earth orbit. To address this need, research and development is presented regarding two enabling technologies. The first is a self-adjusting and aligning (SAA) FSW tool that drastically reduces the axial force that has historically been quite large. The SAA-FSW tool is a bobbin style tool that floats freely, withoutmore » any external actuators, along its vertical axis to adjust and align with the workpiece s position and orientation. Successful butt welding of 1/8 in. (3.175 mm) thick aluminum 1100 was achieved in conjunction with a drastic reduction and near elimination of the axial process force. Along with the SAA-FSW, an innovative in-process monitor technique is presented in which a magnetoelastic force rate-of-change sensor is employed. The sensor consists of a magnetized FSW tool that is used to induce a voltage in a coil surrounding the tool when changes to the process forces occur. The sensor was able to detect 1/16 in. (1.5875 mm) diameter voids. It is concluded that these technologies could be applied toward the development of a portable FSW machine for use in space.« less

  3. Modeling the human body/seat system in a vibration environment.

    PubMed

    Rosen, Jacob; Arcan, Mircea

    2003-04-01

    The vibration environment is a common man-made artificial surrounding with which humans have a limited tolerance to cope due to their body dynamics. This research studied the dynamic characteristics of a seated human body/seat system in a vibration environment. The main result is a multi degrees of freedom lumped parameter model that synthesizes two basic dynamics: (i) global human dynamics, the apparent mass phenomenon, including a systematic set of the model parameters for simulating various conditions like body posture, backrest, footrest, muscle tension, and vibration directions, and (ii) the local human dynamics, represented by the human pelvis/vibrating seat contact, using a cushioning interface. The model and its selected parameters successfully described the main effects of the apparent mass phenomenon compared to experimental data documented in the literature. The model provided an analytical tool for human body dynamics research. It also enabled a primary tool for seat and cushioning design. The model was further used to develop design guidelines for a composite cushion using the principle of quasi-uniform body/seat contact force distribution. In terms of evenly distributing the contact forces, the best result for the different materials and cushion geometries simulated in the current study was achieved using a two layer shaped geometry cushion built from three materials. Combining the geometry and the mechanical characteristics of a structure under large deformation into a lumped parameter model enables successful analysis of the human/seat interface system and provides practical results for body protection in dynamic environment.

  4. Effect of Vibration on Pain Response to Heel Lance: A Pilot Randomized Control Trial.

    PubMed

    McGinnis, Kate; Murray, Eileen; Cherven, Brooke; McCracken, Courtney; Travers, Curtis

    2016-12-01

    Applied mechanical vibration in pediatric and adult populations has been shown to be an effective analgesic for acute and chronic pain, including needle pain. Studies among the neonatal population are lacking. According to the Gate Control Theory, it is expected that applied mechanical vibration will have a summative effect with standard nonpharmacologic pain control strategies, reducing behavioral and physiologic pain responses to heel lancing. To determine the safety and efficacy of mechanical vibration for relief of heel lance pain among neonates. In this parallel design randomized controlled trial, eligible enrolled term or term-corrected neonates (n = 56) in a level IV neonatal intensive care unit were randomized to receive either sucrose and swaddling or sucrose, swaddling, and vibration for heel lance analgesia. Vibration was applied using a handheld battery-powered vibrator (Norco MiniVibrator, Hz = 92) to the lateral aspect of the lower leg along the sural dermatome throughout the heel lance procedure. Neonatal Pain, Agitation, and Sedation Scale (N-PASS) scores, heart rate, and oxygen saturations were collected at defined intervals surrounding heel lancing. Infants in the vibration group (n = 30) had significantly lower N-PASS scores and more stable heart rates during heel stick (P = .006, P = .037) and 2 minutes after heel lance (P = .002, P = .016) than those in the nonvibration group. There were no adverse behavioral or physiologic responses to applied vibration in the sample. Applied mechanical vibration is a safe and effective method for managing heel lance pain. This pilot study suggests that mechanical vibration warrants further exploration as a nonpharmacologic pain management tool among the neonatal population.

  5. Comparison of a pocket-size ultrasound device with a premium ultrasound machine: diagnostic value and time required in bedside ultrasound examination.

    PubMed

    Stock, Konrad Friedrich; Klein, Bettina; Steubl, Dominik; Lersch, Christian; Heemann, Uwe; Wagenpfeil, Stefan; Eyer, Florian; Clevert, Dir-Andre

    2015-10-01

    Time savings and clinical accuracy of a new miniature ultrasound device was investigated utilizing comparison with conventional high-end ultrasound instruments. Our objective was to determine appropriate usage and limitations of this diagnostic tool in internal medicine. We investigated 28 patients from the internal-medicine department. Patients were examined with the Acuson P10 portable device and a Sonoline Antares instrument in a cross-over design. All investigations were carried out at the bedside; the results were entered on a standardized report form. The time for the ultrasound examination (transfer time, setting up and disassembly, switching on and off, and complete investigation time) was recorded separately. Mean time for overall examination per patient with the portable ultrasound device was shorter (25.0 ± 4.5 min) than with the high-end machine (29.4 ± 4.4 min; p < 0.001). When measuring the size of liver, spleen, and kidneys, the values obtained differed significantly between portable device and the high-end instrument. In our study, we identified 113 pathological ultrasound findings with the high-end ultrasound machine, while 82 pathological findings (73%) were concordantly detected with the portable ultrasound device. The main diagnostic strengths of the portable device were in the detection of ascites (sensitivity 80%), diagnosis of fatty liver, and identification of severe parenchymal liver damage. The clinical utility of portable ultrasound machines is limited. There will be clinical roles for distinct clinical questions such as detection of ascites or pleural effusion when used by experienced examiners. However, sensitivity in detecting multiple pathologies is not comparable to high-end ultrasound machines.

  6. Endoscopic fringe projection for in-situ inspection of a sheet-bulk metal forming process

    NASA Astrophysics Data System (ADS)

    Matthias, Steffen; Kästner, Markus; Reithmeier, Eduard

    2015-05-01

    Sheet-bulk metal forming is a new production process capable of performing deep-drawing and massive forming steps in a single operation. However, due to the high forming forces of the forming process, continuous process control is required in order to detect wear on the forming tool before production quality is impacted. To be able to measure the geometry of the forming tool in the limited space of forming presses, a new inspection system is being developed within the SFB/TR 73 collaborative research center. In addition to the limited space, the process restricts the amount of time available for inspection. Existing areal optical measurement systems suffer from shadowing when measuring the tool's inner elements, as they cannot be placed in the limited space next to the tool, while tactile measurement systems cannot meet the time restrictions for measuring the areal geometries. The new inspection system uses the fringe projection optical measurement principle to capture areal geometry data from relevant parts of the forming tool in short time. Highresolution image fibers are used to connect the system's compact sensor head to a base unit containing both camera and projector of the fringe projection system, which can be positioned outside of the moving parts of the press. To enable short measurement times, a high intensity laser source is used in the projector in combination with a digital micro-mirror device. Gradient index lenses are featured in the sensor head to allow for a very compact design that can be used in the narrow space above the forming tool inside the press. The sensor head is attached to an extended arm, which also guides the image fibers to the base unit. A rotation stage offers the possibility to capture measurements of different functional elements on the circular forming tool by changing the orientation of the sensor head next to the forming tool. During operation of the press, the arm can be travelled out of the moving parts of the forming press. To further reduce the measurement times of the fringe projection system, the inverse fringe projection principle has been adapted to the system to detect geometry deviations in a single camera image. Challenges arise from vibrations of both the forming machine and the positioning stages, which are transferred via the extended arm to the sensor head. Vibrations interfere with the analysis algorithms of both encoded and inverse fringe projection and thus impair measurement accuracy. To evaluate the impact of vibrations on the endoscopic system, results of measurements of simple geometries under the influence of vibrations are discussed. The effect of vibrations is imitated by displacing the measurement specimen during the measurement with a linear positioning stage. The concept of the new inspection system is presented within the scope of the TR 73 demonstrational sheet-bulk metal forming process. Finally, the capabilities of the endoscopic fringe projection system are shown by measurements of gearing structures on a forming tool compared to a CAD-reference.

  7. Evaluation on the Perception of the New Portable Set for Hajj Course (P.A.H.A.M) Based on Design Characteristics

    NASA Astrophysics Data System (ADS)

    Shahir Yahya, Mohd; Rahim, Abd Khalil Abd; Mohammad, Musli; Ibrahim, Mustaffa; Kadis, Ghazali

    2017-08-01

    This paper is about the perceptions of the pilgrims to the innovation of the portable training set for hajj course (P.A.H.A.M). The acronym P.A.H.A.M come from the Malay word “Praktikal Haji Mudahalih” as a tool in helping the hajj and umrah pilgrims to better understand the concept while doing the hajj and umrah practical. In Malaysia, one of the managing bodies of pilgrimage for Muslims in is Pilgrims Fund Board. It provides a series of courses every year to help in boosting the understanding of the pilgrims before leaving for the Holy Land. During the practical session, they will provide the replica model to help pilgrims to familiarise themselves with the actual situation in Mecca. However, the current replica model was built using an iron structure that is relatively heavy, not portable and embarks more cost of transportation and labour. Therefore, this paper discusses the perceptions of the pilgrims on the characteristics of Portable Training Set for Hajj Course (P.A.H.A.M) compared to the existing set in order to increase the understanding of pilgrims. A total of 53 samples of hajj and umrah pilgrims participated in this study consisted of the general public. From the data analysed using Statistical Software for Social Sciences (SPSS v19), the results of the survey showed that more than 90% of respondents agreed that this portable training set meets the characteristics such as easy to handle, more safety in crowd, portable, stability, light weight, suitable in-door and out-door activity, easy to clean, and more structured with average score 4.00 (agreed) and above. In conclusion, it is expected that this Portable Training Set for Hajj Course (P.A.H.A.M) can be used by Muslim’s communities in Malaysia particularly and Muslim countries in general to better understand the hajj and umrah activities before leaving to the Holy Land.

  8. Podcasting: contemporary patient education.

    PubMed

    Abreu, Daniel V; Tamura, Thomas K; Sipp, J Andrew; Keamy, Donald G; Eavey, Roland D

    2008-04-01

    Portable video technology is a widely available new tool with potential to be used by pediatric otolaryngology practices for patient and family education. Podcasts are media broadcasts that employ this new technology. They can be accessed via the Internet and viewed either on a personal computer or on a handheld device, such as an iPod or an MP3 player. We wished to examine the feasibility of establishing a podcast-hosting Web site. We digitally recorded pediatric otologic procedures in the operating room and saved the digital files to DVDs. We then edited the DVDs at home with video-editing software on a personal computer. Next, spoken narrative was recorded with audio-recording software and combined with the edited video clips. The final products were converted into the M4V file format, and the final versions were uploaded onto our hospital's Web site. We then downloaded the podcasts onto a high-quality portable media player so that we could evaluate their quality. All of the podcasts are now on the hospital Web site, where they can be downloaded by patients and families at no cost. The site includes instructions on how to download the appropriate free software for viewing the podcasts on a portable media player or on a computer. Using this technology for patient education expands the audience and permits portability of information. We conclude that a home computer can be used to inexpensively create informative surgery demonstrations that can be accessed via a Web site and transferred to portable viewing devices with excellent quality.

  9. Advances in the in Vivo Raman Spectroscopy of Malignant Skin Tumors Using Portable Instrumentation

    PubMed Central

    Kourkoumelis, Nikolaos; Balatsoukas, Ioannis; Moulia, Violetta; Elka, Aspasia; Gaitanis, Georgios; Bassukas, Ioannis D.

    2015-01-01

    Raman spectroscopy has emerged as a promising tool for real-time clinical diagnosis of malignant skin tumors offering a number of potential advantages: it is non-intrusive, it requires no sample preparation, and it features high chemical specificity with minimal water interference. However, in vivo tissue evaluation and accurate histopathological classification remain a challenging task for the successful transition from laboratory prototypes to clinical devices. In the literature, there are numerous reports on the applications of Raman spectroscopy to biomedical research and cancer diagnostics. Nevertheless, cases where real-time, portable instrumentations have been employed for the in vivo evaluation of skin lesions are scarce, despite their advantages in use as medical devices in the clinical setting. This paper reviews the advances in real-time Raman spectroscopy for the in vivo characterization of common skin lesions. The translational momentum of Raman spectroscopy towards the clinical practice is revealed by (i) assembling the technical specifications of portable systems and (ii) analyzing the spectral characteristics of in vivo measurements. PMID:26132563

  10. Design of a portable imager for near-infrared visualization of cutaneous wounds

    PubMed Central

    Peng, Zhaoqiang; Zhou, Jun; Dacy, Ashley; Zhao, Deyin; Kearney, Vasant; Zhou, Weidong; Tang, Liping; Hu, Wenjing

    2017-01-01

    Abstract. A portable imager developed for real-time imaging of cutaneous wounds in research settings is described. The imager consists of a high-resolution near-infrared CCD camera capable of detecting both bioluminescence and fluorescence illuminated by an LED ring with a rotatable filter wheel. All external components are integrated into a compact camera attachment. The device is demonstrated to have competitive performance with a commercial animal imaging enclosure box setup in beam uniformity and sensitivity. Specifically, the device was used to visualize the bioluminescence associated with increased reactive oxygen species activity during the wound healing process in a cutaneous wound inflammation model. In addition, this device was employed to observe the fluorescence associated with the activity of matrix metalloproteinases in a mouse lipopolysaccharide-induced infection model. Our results support the use of the portable imager design as a noninvasive and real-time imaging tool to assess the extent of wound inflammation and infection. PMID:28114448

  11. Pulsed laser diode photoacoustic tomography (PLD-PAT) system for fast in vivo imaging of small animal brain

    NASA Astrophysics Data System (ADS)

    Upputuri, Paul Kumar; Kalva, Sandeep Kumar; Moothanchery, Mohesh; Pramanik, Manojit

    2017-03-01

    In recent years, high-repetition rate pulsed laser diode (PLD) was used as an alternative to the Nd:YAG lasers for photoacoustic tomography (PAT). The use of PLD makes the overall PAT system, a low-cost, portable, and high frame rate imaging tool for preclinical applications. In this work, we will present a portable in vivo pulsed laser diode based photoacoustic tomography (PLD-PAT) system. The PLD is integrated inside a circular scanning geometry. The PLD can provide near-infrared ( 803 nm) pulses with pulse duration 136 ns, and pulse energy 1.4 mJ / pulse at 7 kHz repetition rate. The system will be demonstrated for in vivo fast imaging of small animal brain. To enhance the contrast of brain imaging, experiments will be carried out using contrast agents which have strong absorption around laser excitation wavelength. This low-cost, portable small animal brain imaging system could be very useful for brain tumor imaging and therapy.

  12. Smartphone based hand-held quantitative phase microscope using the transport of intensity equation method.

    PubMed

    Meng, Xin; Huang, Huachuan; Yan, Keding; Tian, Xiaolin; Yu, Wei; Cui, Haoyang; Kong, Yan; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2016-12-20

    In order to realize high contrast imaging with portable devices for potential mobile healthcare, we demonstrate a hand-held smartphone based quantitative phase microscope using the transport of intensity equation method. With a cost-effective illumination source and compact microscope system, multi-focal images of samples can be captured by the smartphone's camera via manual focusing. Phase retrieval is performed using a self-developed Android application, which calculates sample phases from multi-plane intensities via solving the Poisson equation. We test the portable microscope using a random phase plate with known phases, and to further demonstrate its performance, a red blood cell smear, a Pap smear and monocot root and broad bean epidermis sections are also successfully imaged. Considering its advantages as an accurate, high-contrast, cost-effective and field-portable device, the smartphone based hand-held quantitative phase microscope is a promising tool which can be adopted in the future in remote healthcare and medical diagnosis.

  13. MPA Portable: A Stand-Alone Software Package for Analyzing Metaproteome Samples on the Go.

    PubMed

    Muth, Thilo; Kohrs, Fabian; Heyer, Robert; Benndorf, Dirk; Rapp, Erdmann; Reichl, Udo; Martens, Lennart; Renard, Bernhard Y

    2018-01-02

    Metaproteomics, the mass spectrometry-based analysis of proteins from multispecies samples faces severe challenges concerning data analysis and results interpretation. To overcome these shortcomings, we here introduce the MetaProteomeAnalyzer (MPA) Portable software. In contrast to the original server-based MPA application, this newly developed tool no longer requires computational expertise for installation and is now independent of any relational database system. In addition, MPA Portable now supports state-of-the-art database search engines and a convenient command line interface for high-performance data processing tasks. While search engine results can easily be combined to increase the protein identification yield, an additional two-step workflow is implemented to provide sufficient analysis resolution for further postprocessing steps, such as protein grouping as well as taxonomic and functional annotation. Our new application has been developed with a focus on intuitive usability, adherence to data standards, and adaptation to Web-based workflow platforms. The open source software package can be found at https://github.com/compomics/meta-proteome-analyzer .

  14. Gem and mineral identification using GL Gem Raman and comparison with other portable instruments

    NASA Astrophysics Data System (ADS)

    Culka, Adam; Hyršl, Jaroslav; Jehlička, Jan

    2016-11-01

    Several mainly silicate minerals in their gemstone varieties have been analysed by the Gem Raman portable system by Gemlab R&T, Vancouver, Canada, in order to ascertain the general performance of this relatively non-expensive tool developed exactly for the purpose of gemstone identification. The Raman spectra of gemstones acquired by this system have been subsequently critically compared with the data obtained by several other portable or handheld Raman instruments. The Raman spectra acquired with the Gem Raman instrument were typically of lesser quality when compared with the spectra taken by other instruments. Characteristic features such as steep baseline probably due to the fluorescence of the minerals, Raman bands much broader and therefore less resolved closely located Raman bands, and generally greater shifts of the band positions from the reference values were encountered. Some gemstone groups such as rubies did not provide useful Raman spectra at all. Nevertheless, general identification of gemstones was possible for a selection of gemstones.

  15. Applications of Microcomputers in the Education of the Physically Disabled Child.

    ERIC Educational Resources Information Center

    Foulds, Richard A.

    1982-01-01

    Microcomputers can serve as expressive communication tools for severely physically disabled persons. Features such as single input devices, direct selection aids, and speech synthesis capabilities can be extremely useful. The trend toward portable battery-operated computers will make the technology even more accessible. (CL)

  16. 18 CFR 367.51 - Components of construction.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Components of construction. 367.51 Section 367.51 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... short life, including small portable tools and implements, must not be charged to service company...

  17. 18 CFR 367.51 - Components of construction.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Components of construction. 367.51 Section 367.51 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... short life, including small portable tools and implements, must not be charged to service company...

  18. 18 CFR 367.57 - Equipment.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Equipment. 367.57 Section 367.57 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT... equipment accounts hand and other portable tools, that are likely to be lost or stolen or that have...

  19. 18 CFR 367.57 - Equipment.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Equipment. 367.57 Section 367.57 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT... equipment accounts hand and other portable tools, that are likely to be lost or stolen or that have...

  20. 18 CFR 367.51 - Components of construction.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Components of construction. 367.51 Section 367.51 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... short life, including small portable tools and implements, must not be charged to service company...

  1. 18 CFR 367.57 - Equipment.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Equipment. 367.57 Section 367.57 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT... equipment accounts hand and other portable tools, that are likely to be lost or stolen or that have...

  2. 18 CFR 367.51 - Components of construction.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Components of construction. 367.51 Section 367.51 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... short life, including small portable tools and implements, must not be charged to service company...

  3. 18 CFR 367.57 - Equipment.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Equipment. 367.57 Section 367.57 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT... equipment accounts hand and other portable tools, that are likely to be lost or stolen or that have...

  4. Masonry Specialist.

    ERIC Educational Resources Information Center

    Air Force Training Command, Sheppard AFB, TX.

    This instructional package is intended for use in training Air Force personnel enrolled in a program for apprentice masons. Training includes an introduction to masonry and provides instruction in the use of masons' hand, portable power, and shop tools; construction and maintenance of masonry structures using brick, concrete block, and tile;…

  5. Diagnostic Analyzer for Gearboxes (DAG): User's Guide. Version 3.1 for Microsoft Windows 3.1

    NASA Technical Reports Server (NTRS)

    Jammu, Vinay B.; Kourosh, Danai

    1997-01-01

    This documentation describes the Diagnostic Analyzer for Gearboxes (DAG) software for performing fault diagnosis of gearboxes. First, the user would construct a graphical representation of the gearbox using the gear, bearing, shaft, and sensor tools contained in the DAG software. Next, a set of vibration features obtained by processing the vibration signals recorded from the gearbox using a signal analyzer is required. Given this information, the DAG software uses an unsupervised neural network referred to as the Fault Detection Network (FDN) to identify the occurrence of faults, and a pattern classifier called Single Category-Based Classifier (SCBC) for abnormality scaling of individual vibration features. The abnormality-scaled vibration features are then used as inputs to a Structure-Based Connectionist Network (SBCN) for identifying faults in gearbox subsystems and components. The weights of the SBCN represent its diagnostic knowledge and are derived from the structure of the gearbox graphically presented in DAG. The outputs of SBCN are fault possibility values between 0 and 1 for individual subsystems and components in the gearbox with a 1 representing a definite fault and a 0 representing normality. This manual describes the steps involved in creating the diagnostic gearbox model, along with the options and analysis tools of the DAG software.

  6. An iOS Application for Evaluating Whole-body Vibration Within a Workplace Risk Management Process.

    PubMed

    McGlothlin, James; Burgess-Limerick, R; Lynas, D

    2015-01-01

    Workplace management of whole-body vibration exposure requires systematic collection of whole-body vibration data in conjunction with the numerous variables which influence vibration amplitudes. The cost and complexity of commercially available measurement devices is an impediment to the routine collection of such data by workplaces. An iOS application (WBV) has been developed which allows an iPod Touch to be used to measure whole-body vibration exposures. The utility of the application was demonstrated by simultaneously obtaining 98 pairs of whole-body vibration measurements from both the iPod Touch application and a commercially available whole-body vibration device during the operation of a variety of vehicles and mobile plant in operation at a surface coal mine. The iOS application installed on a fifth-generation iPod Touch was shown to provide a 95% confidence of +/- 0.077 m/s(2) r.m.s. constant error for the vertical direction. Situations in which vibration levels lay within the ISO2631.1 health guidance caution zone were accurately identified, and the qualitative features of the frequency spectra were reproduced. The low cost and relative simplicity of the application has potential to facilitate its use as a screening tool to identify situations in which musculoskeletal disorders may arise as a consequence of exposure to whole-body vibration.

  7. Hybrid nanogenerators for low frequency vibration energy harvesting and self-powered wireless locating

    NASA Astrophysics Data System (ADS)

    Yuan, Ying; Zhang, Hulin; Wang, Jie; Xie, Yuhang; Khan, Saeed Ahmed; Jin, Long; Yan, Zhuocheng; Huang, Long; Pan, Taisong; Yang, Weiqing; Lin, Yuan

    2018-01-01

    Hybrid energy harvesters based on different physical effects is fascinating, but a rational design for multiple energy harvesting is challenging. In this work, a spring-magnet oscillator-based triboelectric-electromagnetic generator (EMG) with a solar cell cap is proposed. A power was produced by a triboelectric nanogenerator (TENG) and an EMG independently or simultaneously by using a shared spring-magnet oscillator. The oscillator configuration enables versatile energy harvesting with the excellent size scalability and self-packaged structure which can perform well at low frequency ranging from 3.5 to 5 Hz. The solar cell cap mounted above the oscillator can harvest solar energy. Under vibrations at the frequency of 4 Hz, the TENG and the EMG produced maximum output power of 5.46 nW cm-3 and 378.79 μW cm-3, respectively. The generated electricity by the hybrid nanogenerator can be stored in a capacitor or Li-ion battery, which is capable of powering a wireless locator for real-time locating data reporting to a personal cell phone. The light-weight and handy hybrid nanogenerator can directly light a caution light or play as a portable flashlight by shaking hands at night.

  8. Towards a non-invasive quantitative analysis of the organic components in museum objects varnishes by vibrational spectroscopies: methodological approach.

    PubMed

    Daher, Céline; Pimenta, Vanessa; Bellot-Gurlet, Ludovic

    2014-11-01

    The compositions of ancient varnishes are mainly determined destructively by separation methods coupled to mass spectrometry. In this study, a methodology for non-invasive quantitative analyses of varnishes by vibrational spectroscopies is proposed. For that, experimental simplified varnishes of colophony and linseed oil were prepared according to 18th century traditional recipes with an increasing mass concentration ratio of colophony/linseed oil. FT-Raman and IR analyses using ATR and non-invasive reflectance modes were done on the "pure" materials and on the different mixtures. Then, a new approach involving spectral decomposition calculation was developed considering the mixture spectra as a linear combination of the pure materials ones, and giving a relative amount of each component. Specific spectral regions were treated and the obtained results show a good accuracy between the prepared and calculated amounts of the two compounds. We were thus able to detect and quantify from 10% to 50% of colophony in linseed oil using non-invasive techniques that can also be conducted in situ with portable instruments when it comes to museum varnished objects and artifacts. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. ANTIVIBRATION GLOVES: EFFECTS ON VASCULAR AND SENSORINEURAL FUNCTION, AN ANIMAL MODEL

    PubMed Central

    Krajnak, K.; Waugh, S.; Johnson, C.; Miller, R. G.; Welcome, D.; Xu, X.; Warren, C.; Sarkisian, S.; Andrew, M.; Dong, R. G.

    2015-01-01

    Anti-vibration gloves have been used to block the transmission of vibration from powered hand tools to the user, and to protect users from the negative health consequences associated with exposure to vibration. However, there are conflicting reports as to the efficacy of gloves in protecting workers. The goal of this study was to use a characterized animal model of vibration-induced peripheral vascular and nerve injury to determine whether antivibration materials reduced or inhibited the effects of vibration on these physiological symptoms. Rats were exposed to 4 h of tail vibration at 125 Hz with an acceleration 49 m/s2. The platform was either bare or covered with antivibrating glove material. Rats were tested for tactile sensitivity to applied pressure before and after vibration exposure. One day following the exposure, ventral tail arteries were assessed for sensitivity to vasodilating and vasoconstricting factors and nerves were examined histologically for early indicators of edema and inflammation. Ventral tail artery responses to an α2C-adrenoreceptor agonist were enhanced in arteries from vibration-exposed rats compared to controls, regardless of whether antivibration materials were used or not. Rats exposed to vibration were also less sensitive to pressure after exposure. These findings are consistent with experimental findings in humans suggesting that antivibration gloves may not provide protection against the adverse health consequences of vibration exposure in all conditions. Additional studies need to be done examining newer antivibration materials. PMID:25965192

  10. The Development of Vibration System for Applying Magnetic Resonance Elastography (MRE) to the Supraspinatus Muscle.

    PubMed

    Ito, Daiki; Numano, Tomokazu; Mizuhara, Kazuyuki; Takamoto, Kouichi; Onishi, Takaaki; Nishijo, Hisao

    2016-01-01

    Palpation is a standard clinical tool to diagnose abnormal stiffness changes in soft tissues. However, it is difficult to palpate the supraspinatus muscle because it locates under the trapezius muscle. The magnetic resonance elastography (MRE) uses harmonic mechanical excitation to quantitatively measure the stiffness (shear modulus) of both the superficial and deep tissues. The purpose of this study was to build a vibration system for applying the MRE to the supraspinatus muscle. In this study, a power amplifier and a pneumatic pressure generator were used to supply vibrations to a vibration pad. Six healthy volunteers underwent MRE. We investigated the effects of position (the head of the humerus and the trapezius muscle) of the vibration pad on the patterns of wave propagation (wave image). When the vibration pad was placed in the trapezius muscle, the wave images represented clear wave propagation. On the other hand, when the vibration pad was placed in the head of the humerus, the wave images represented unclear wave propagation. This result might be caused by wave interferences resulting from the vibrations from bones and an intramuscular tendon of the supraspinatus muscle. The mean shear modulus also was 8.12 ± 1.83 (mean ± SD) kPa, when the vibration pad was placed in the trapezius muscle. Our results demonstrated that the vibration pad should be placed in the trapezius muscle in the MRE of the supraspinatus muscle.

  11. Effectiveness of new vibration delivery system on pain associated with injection of local anesthesia in children.

    PubMed

    Shilpapriya, Mangalampally; Jayanthi, Mungara; Reddy, Venumbaka Nilaya; Sakthivel, Rajendran; Selvaraju, Girija; Vijayakumar, Poornima

    2015-01-01

    Pain is highly subjective and it is neurologically proven that stimulation of larger diameter fibers - e.g., using appropriate coldness, warmth, rubbing, pressure or vibration - can close the neural "gate" so that the central perception of itch and pain is reduced. This fact is based upon "gate control" theory of Melzack and Wall. The present study was carried out to investigate the effects of vibration stimuli on pain experienced during local anesthetic injections. Thirty patients aged 6-12 years old of both the genders with Frankel's behavior rating scale as positive and definitely positive requiring bilateral local anesthesia injections for dental treatment were included in the split-mouth cross over design. Universal pain assessment tool was used to assess the pain with and without vibration during the administration of local anesthesia and the results obtained were tabulated and statistically analyzed. Local anesthetic administration with vibration resulted in significantly less pain (P = 0.001) compared to the injections without the use of vibe. The results suggest that vibration can be used as an effective method to decrease pain during dental local anesthetic administration.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, S.H.; Oxoby, G.J.; Trang, Q.H.

    The advent of the personal microcomputer provides a new tool for the debugging, calibration and monitoring of small scale physics apparatus; e.g., a single detector being developed for a larger physics apparatus. With an appropriate interface these microcomputer systems provide a low cost (1/3 the cost of a comparable minicomputer system), convenient, dedicated, portable system which can be used in a fashion similar to that of portable oscilloscopes. Here we describe an interface between the Apple computer and CAMAC which is now being used to study the detector for a Cerenkov ring-imaging device. The Apple is particularly well-suited to thismore » application because of its ease of use, hi-resolution graphics peripheral buss and documentation support.« less

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oxoby, G.J.; Trang, Q.H.; Williams, S.H.

    The advent of the personal microcomputer provides a new tool for the debugging, calibration and monitoring of small scale physics apparatus, e.g., a single detector being developed for a larger physics apparatus. With an appropriate interface these microcomputer systems provide a low cost (1/3 the cost of a comparable minicomputer system), convenient, dedicated, portable system which can be used in a fashion similar to that of portable oscilloscopes. Here, an interface between the Apple computer and CAMAC which is now being used to study the detector for a Cerenkov ring-imaging device is described. The Apple is particularly well-suited to thismore » application because of its ease of use, hi-resolution graphics, peripheral bus and documentation support.« less

  14. Automated Fast Screening Method for Cocaine Identification in Seized Drug Samples Using a Portable Fourier Transform Infrared (FT-IR) Instrument.

    PubMed

    Mainali, Dipak; Seelenbinder, John

    2016-05-01

    Quick and presumptive identification of seized drug samples without destroying evidence is necessary for law enforcement officials to control the trafficking and abuse of drugs. This work reports an automated screening method to detect the presence of cocaine in seized samples using portable Fourier transform infrared (FT-IR) spectrometers. The method is based on the identification of well-defined characteristic vibrational frequencies related to the functional group of the cocaine molecule and is fully automated through the use of an expert system. Traditionally, analysts look for key functional group bands in the infrared spectra and characterization of the molecules present is dependent on user interpretation. This implies the need for user expertise, especially in samples that likely are mixtures. As such, this approach is biased and also not suitable for non-experts. The method proposed in this work uses the well-established "center of gravity" peak picking mathematical algorithm and combines it with the conditional reporting feature in MicroLab software to provide an automated method that can be successfully employed by users with varied experience levels. The method reports the confidence level of cocaine present only when a certain number of cocaine related peaks are identified by the automated method. Unlike library search and chemometric methods that are dependent on the library database or the training set samples used to build the calibration model, the proposed method is relatively independent of adulterants and diluents present in the seized mixture. This automated method in combination with a portable FT-IR spectrometer provides law enforcement officials, criminal investigators, or forensic experts a quick field-based prescreening capability for the presence of cocaine in seized drug samples. © The Author(s) 2016.

  15. 76 FR 59162 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-National Center...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-23

    ... Lake, IL; Climax Portable Machine Tools, Inc., Newberg, OR; Clockwork Solutions, Inc. (CSI), Austin, TX..., MA; University of Texas Austin, Austin, TX; Vista Controls, Inc., dba Curtiss-Wright Controls... DEPARTMENT OF JUSTICE Antitrust Division Notice Pursuant to the National Cooperative Research and...

  16. From Web 2.0 to Teacher 2.0

    ERIC Educational Resources Information Center

    Thomas, David A.; Li, Qing

    2008-01-01

    The World Wide Web is evolving in response to users who demand faster and more efficient access to information, portability, and reusability of digital objects between Web-based and computer-based applications and powerful communication, publication, collaboration, and teaching and learning tools. This article reviews current uses of Web-based…

  17. 29 CFR 1926.404 - Wiring design and protection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Portable and mobile X-ray and associated equipment; (4) Tools likely to be used in wet and/or conductive...) The noncurrent-carrying metal parts of equipment and the equipment grounding conductor terminals of... receptacles mounted on the vehicle or on the generator, and (C) The noncurrent-carrying metal parts of...

  18. 29 CFR 1926.404 - Wiring design and protection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Portable and mobile X-ray and associated equipment; (4) Tools likely to be used in wet and/or conductive...) The noncurrent-carrying metal parts of equipment and the equipment grounding conductor terminals of... receptacles mounted on the vehicle or on the generator, and (C) The noncurrent-carrying metal parts of...

  19. In Sync with Science Teaching

    ERIC Educational Resources Information Center

    Scribner-MacLean, Michelle; Nikonchuk, Andrew; Kaplo, Patrick; Wall, Michael

    2006-01-01

    Science educators are often among the first to use emerging technologies in the classroom and laboratory. For the technologically savvy science teacher, the handheld computer is a terrific tool. A handheld computer is a portable electronic device that helps organize (via calendars, contact lists, to-do lists) and integrate electronic data…

  20. An Environmental Technology Verification (ETV) Testing of a Ballast Exchange Assurance Meter (BEAM) 100

    EPA Science Inventory

    Mid-ocean ballast water exchange (BWE) is mandatory for all vessels entering U.S. waters from outside the 200-mile exclusive economic zone. To support such regulation, accurate and portable verification tools are needed for determining that BWE has taken place. One parameter pr...

  1. Use of Videorecording Equipment as an Educational Tool.

    ERIC Educational Resources Information Center

    Webster, Harold J.

    The faculty at the DuBois Campus of the Pennsylvania State University are using video recording equipment in a variety of ways. Student performances are videotaped for different purposes in speech, marketing, and physical education classes. Professors in the Wildlife Technology Program are using portable videotaping equipment to record activities…

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shishlo, Andrei P; Chu, Paul; Pelaia II, Tom

    A data plotting package residing in the XAL tools set is presented. This package is based on Java SWING, and therefore it has the same portability as Java itself. The data types for charts, bar-charts, and color-surface plots are described. The algorithms, performance, interactive capabilities, limitations, and the best usage practices of this plotting package are discussed.

  3. Use of a portable monitoring device (Somnocheck Micro) for the investigation and diagnosis of obstructive sleep apnoea in comparison with polysomnography.

    PubMed

    Bilgin, Cahit; Erkorkmaz, Unal; Ucar, Muhammed Kursad; Akin, Nese; Nalbant, Ahmet; Annakkaya, Ali Nihat

    2016-01-01

    Polysomnography (PSG) remains the gold standard for the diagnosis of obstructive sleep apnoea syndrome (OSAS). While PSG is essential for OSAS, this technique is not suitable for epidemiological investigation due to its high cost. This study aimed to compare a portable monitoring device with PSG for the measurement of parameters related to the diagnosis of OSAS in rural areas. We conducted a descriptive study of 155 patients (30 women and 125 men; mean age, 52±12years) who visited to the Hendek Government Hospital Sleep Laboratory between February 2011 and January 2013 Apnoea hypopnea index (AHI), mean levels of O2 (meanO2), desaturation index (DI), and minimum oxygen saturation (minO2) variations as measured using both PSG and a portable Somnocheck Micro (SM) device were compared. Differences were found between the meanO2 and DI, but not between AHI and minO2. Differences between the methods were not desired, but the relationship between the methods was distinct and supported our hypothesis. The results of our study have shown that the SM portable device can be used as an alternative diagnostic tool in this population either at home or in sleep clinic.

  4. Low-Cost, Robust, and Field Portable Smartphone Platform Photometric Sensor for Fluoride Level Detection in Drinking Water.

    PubMed

    Hussain, Iftak; Ahamad, Kamal Uddin; Nath, Pabitra

    2017-01-03

    Groundwater is the major source of drinking water for people living in rural areas of India. Pollutants such as fluoride in groundwater may be present in much higher concentration than the permissible limit. Fluoride does not give any visible coloration to water, and hence, no effort is made to remove or reduce the concentration of this chemical present in drinking water. This may lead to a serious health hazard for those people taking groundwater as their primary source of drinking water. Sophisticated laboratory grade tools such as ion selective electrodes (ISE) and portable spectrophotometers are commercially available for in-field detection of fluoride level in drinking water. However, such tools are generally expensive and require expertise to handle. In this paper, we demonstrate the working of a low cost, robust, and field portable smartphone platform fluoride sensor that can detect and analyze fluoride concentration level in drinking water. For development of the proposed sensor, we utilize the ambient light sensor (ALS) of the smartphone as light intensity detector and its LED flash light as an optical source. An android application "FSense" has been developed which can detect and analyze the fluoride concentration level in water samples. The custom developed application can be used for sharing of in-field sensing data from any remote location to the central water quality monitoring station. We envision that the proposed sensing technique could be useful for initiating a fluoride removal program undertaken by governmental and nongovernmental organizations here in India.

  5. Optimization of a vacuum chamber for vibration measurements.

    PubMed

    Danyluk, Mike; Dhingra, Anoop

    2011-10-01

    A 200 °C high vacuum chamber has been built to improve vibration measurement sensitivity. The optimized design addresses two significant issues: (i) vibration measurements under high vacuum conditions and (ii) use of design optimization tools to reduce operating costs. A test rig consisting of a cylindrical vessel with one access port has been constructed with a welded-bellows assembly used to seal the vessel and enable vibration measurements in high vacuum that are comparable with measurements in air. The welded-bellows assembly provides a force transmissibility of 0.1 or better at 15 Hz excitation under high vacuum conditions. Numerical results based on design optimization of a larger diameter chamber are presented. The general constraints on the new design include material yield stress, chamber first natural frequency, vibration isolation performance, and forced convection heat transfer capabilities over the exterior of the vessel access ports. Operating costs of the new chamber are reduced by 50% compared to a preexisting chamber of similar size and function.

  6. Scaled vibratory feedback can bias muscle use in children with dystonia during a redundant, one-dimensional myocontrol task

    PubMed Central

    Liyanagamage, Shanie A.; Bertucco, Matteo; Bhanpuri, Nasir H.; Sanger, Terence D.

    2016-01-01

    Vibratory feedback can be a useful tool for rehabilitation. We examined its use in children with dystonia to understand how it affects muscle activity in a population that does not respond well to standard rehabilitation. We predicted scaled vibration (i.e. vibration that was directly or inversely proportional to muscle activity) would increase use of the vibrated muscle because of task-relevant sensory information, while non-scaled vibration would not change muscle use. The study was conducted on 11 subjects with dystonia and 14 controls. Each subject underwent 4 different types of vibration on the more dystonic biceps muscle (or non-dominant arm in controls) in a one-dimensional, bimanual myocontrol task. Our results showed that only scaled vibratory feedback could bias muscle use without changing overall performance in children with dystonia. We believe there may be a role in rehabilitation for scaled vibratory feedback to retrain abnormal muscle patterns. PMID:27798370

  7. The LBT real-time based control software to mitigate and compensate vibrations

    NASA Astrophysics Data System (ADS)

    Borelli, J.; Trowitzsch, J.; Brix, M.; Kürster, M.; Gässler, W.; Bertram, T.; Briegel, F.

    2010-07-01

    The Large Binocular Telescope (LBT) uses two 8.4 meters active primary mirrors and two adaptive secondary mirrors on the same mounting to take advantage of its interferometric capabilities. Both applications, interferometry and AO, are sensitive to vibrations. Several measurement campaigns have been carried out at the LBT and their results strongly indicate that a vibration monitoring system is required to improve the performance of LINC-NIRVANA, LBTI, and ARGOS, the laser guided ground layer adaptive optic system. Currently, a control software for mitigation and compensation of the vibrations is being designed. A complex set of algorithms collects real-time vibration data, archiving it for further analysis, and in parallel, generating the tip-tilt and optical path difference (OPD) data for the control loop of the instruments. A real-time data acquisition device equipped with embedded real-time Linux is used in our systems. A set of quick-look tools is currently under development in order to verify if the conditions at the telescope are suitable for interferometric/adaptive observations.

  8. Software-centric View on OVMS for LBT

    NASA Astrophysics Data System (ADS)

    Trowitzsch, J.; Borelli, J.; Pott, J.; Kürster, M.

    2012-09-01

    The performance of infrared interferometry (IF) and adaptive optics (AO) strongly depends on the mitigation and correction of telescope vibrations. Therefore, at the Large Binocular Telescope (LBT) the OVMS, the Optical Path Difference and Vibration Monitoring System, is being installed. It is meant to ensure suitable conditions for adaptive optics and interferometry. The vibration information is collected from accelerometers that are distributed over the optical elements of the LBT. The collected vibration measurements are converted into tip-tilt and optical path difference data. That data is utilized in the control strategies of the LBT adaptive secondary mirrors and the beam combining interferometers, LINC-NIRVANA and LBTI. Within the OVMS the software part is responsibility of the LINC-NIRVANA team at MPIA Heidelberg. It comprises the software for the real-time data acquisition from the accelerometers as well as the related telemetry interface and the vibration monitoring quick look tools. The basic design ideas, implementation details and special features are explained here.

  9. Simulation and characterization of silicon-based 0.5-MHz ultrasonic nozzles

    NASA Astrophysics Data System (ADS)

    Song, Y. L.; Tsai, S. C.; Chen, W. J.; Chou, Y. F.; Tseng, T. K.; Tsai, C. S.

    2004-01-01

    This paper compares the simulation results with the experimental results of impedance analysis and longitudinal vibration measurement of micro-fabricated 0.5 MHz silicon-based ultrasonic nozzles. Impedance analysis serves as a good diagnostic tool for evaluation of longitudinal vibration of the nozzles. Each nozzle is made of a piezoelectric drive section and a silicon-resonator consisting of multiple Fourier horns each with half wavelength design and twice amplitude magnification. The experimental results verified the simulation prediction of one pure longitudinal vibration mode at the resonant frequency in excellent agreement with the design value. Furthermore, at the resonant frequency, the measured longitudinal vibration amplitude gain at the nozzle tip increases as the number of Fourier horns (n) increases in good agreement with the theoretical value of 2n. Using this design, very high vibration amplitude at the nozzle tip can be achieved with no reduction in the tip cross sectional area. Therefore, the required electric drive power should be drastically reduced, decreasing the likelihood of transducer failure in ultrasonic atomization.

  10. Sound reduction of air compressors using a systematic approach

    NASA Astrophysics Data System (ADS)

    Moylan, Justin Tharp

    The noise emitted by portable electric air compressors can often be a nuisance or potentially hazardous to the operator or others nearby. Therefore, reducing the noise of these air compressors is desired. This research focuses on compressors with a reciprocating piston design as this is the most common type of pump design for portable compressors. An experimental setup was developed to measure the sound and vibration of the air compressors, including testing inside a semi-anechoic chamber. The design of a quiet air compressor was performed in four stages: 1) Teardown and benchmarking of air compressors, 2) Identification and isolation of noise sources, 3) Development of individual means to quiet noise sources, 4) Selection and testing of integrated solutions. The systematic approach and results for each of these stages will be discussed. Two redesigned solutions were developed and measured to be approximately 65% quieter than the previous unmodified compressor. An additional analysis was performed on the solutions selected by the participants involved in the selection process. This analysis involved determining which of the design criteria each participant considered most important when selecting solutions. The results from each participant were then compared to their educational background and experience and correlations were identified. The correlations discovered suggest that educational background and experience may be key determinants for the preference models developed.

  11. Detection of hazardous chemicals using field-portable Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Wright, Cherylyn W.; Harvey, Scott D.; Wright, Bob W.

    2003-07-01

    A major challenge confronting emergency response, border control, and other security-related functions is the accurate, rapid, and safe identification of potentially hazardous chemicals outside a laboratory environment. Raman spectroscopy is a rapid, non-intrusive technique that can be used to confidently identify many classes of hazardous and potentially explosive compounds based on molecular vibration information. Advances in instrumentation now allow reliable field - portable measurements to be made. Before the Raman technique can be effectively applied and be accepted within the scientific community, realistic studies must be performed to develop methods, define limitations, and rigorously evaluate its effectiveness. Examples of a variety of chemicals (including neat and diluted chemical warfare [CW] agents, a CW agent precursor, a biological warfare (BW)-related compound, an illicit drug, and explosives) identified using Raman spectroscopy in various types of containers and on surfaces are given, as well as results from a blind field test of 29 unknown samples which included CW agent precursors and/or degradation products, solvents associated with CW agent production, pesticides, explosives, and BW toxins (mostly mycotoxins). Additionally, results of experimental studies to evaluate the analysis of flammable organic solvents, propellants, military explosives, mixtures containing military explosives, shock-sensitive explosives, and gun powders are described with safety guidelines. Spectral masks for screening unknown samples for explosives and nerve agents are given.

  12. Development of a portable NanoAptamer analyzer for the detection of bisphenol A

    NASA Astrophysics Data System (ADS)

    Son, Ahjeong; Lim, Hyun Jeong; Chua, Beelee

    2017-04-01

    We have demonstrated a portable NanoAptamer analyzer capable of detecting bisphenol A (BPA) at environmentally relevant concentrations (< 1 ng/mL or ppb). It is designed for performing reaction and fluorescence measurement on single cuvette sample. NanoAptamer assay was developed and used as a sensing mechanism where signaling DNA and QD655 was tethered to QD565 and magnetic bead via the aptamer. Aptamer affinity with BPA resulted in the release of the signaling DNA and QD655 from the complex and hence corresponding decrease in QD655 fluorescence measurement signal. Baseline characterization was first performed with empty cuvettes, quantum dots and magnetic beads under near-ideal conditions to establish essential functionality of the NanoAptamer analyzer. Duration of incubation time, number of rinse cycles, and necessity of cuvette vibration were also investigated. In order to demonstrate the capability of the NanoAptamer analyzer to detect BPA, samples with BPA concentrations ranging from 0.0005 to 1.0 ng/mL (ppb) were used. The performance of the NanoAptamer analyzer was further examined by using laboratory protocol and commercial spectrofluorometer as reference. Correlation between NanoAptamer analyzer and laboratory protocol as well as commercial spectrofluorometer was evaluated via correlation plots and correlation coefficients.

  13. Astronaut tool development: An orbital replaceable unit-portable handhold

    NASA Technical Reports Server (NTRS)

    Redmon, John W., Jr.

    1989-01-01

    A tool to be used during astronaut Extra-Vehicular Activity (EVA) replacement of spent or defective electrical/electronic component boxes is described. The generation of requirements and design philosophies are detailed, as well as specifics relating to mechanical development, interface verifications, testing, and astronaut feedback. Findings are presented in the form of: (1) a design which is universally applicable to spacecraft component replacement, and (2) guidelines that the designer of orbital replacement units might incorporate to enhance spacecraft on-orbit maintainability and EVA mission safety.

  14. Per-operative vibration analysis: a valuable tool for defining correct stem insertion: preliminary report.

    PubMed

    Mulier, Michiel; Pastrav, Cesar; Van der Perre, Georges

    2008-01-01

    Defining the stem insertion end point during total hip replacement still relies on the surgeon's feeling. When a custom-made stem prosthesis with an optimal fit into the femoral canal is used, the risk of per-operative fractures is even greater than with standard prostheses. Vibration analysis is used in other clinical settings and has been tested as a means to detect optimal stem insertion in the laboratory. The first per-operative use of vibration analysis during non-cemented custom-made stem insertion in 30 patients is reported here. Thirty patients eligible for total hip replacement with uncemented stem prosthesis were included. The neck of the stem was connected with a shaker that emitted white noise as excitation signal and an impedance head that measured the frequency response. The response signal was sent to a computer that analyzed the frequency response function after each insertion phase. A technician present in the operating theatre but outside the laminated airflow provided feed-back to the surgeon. The correlation index between the frequency response function measured during the last two insertion hammering sessions was >0.99 in 86.7% of the cases. In four cases the surgeon stopped the insertion procedure because of a perceived risk of fracture. Two special cases illustrating the potential benefit of per-operative vibration analysis are described. The results of intra-operative vibration analysis indicate that this technique may be a useful tool assisting the orthopaedic surgeon in defining the insertion endpoint of the stem. The development of a more user-friendly device is therefore warranted.

  15. Development of the software tool for generation and visualization of the finite element head model with bone conduction sounds

    NASA Astrophysics Data System (ADS)

    Nikolić, Dalibor; Milošević, Žarko; Saveljić, Igor; Filipović, Nenad

    2015-12-01

    Vibration of the skull causes a hearing sensation. We call it Bone Conduction (BC) sound. There are several investigations about transmission properties of bone conducted sound. The aim of this study was to develop a software tool for easy generation of the finite element (FE) model of the human head with different materials based on human head anatomy and to calculate sound conduction through the head. Developed software tool generates a model in a few steps. The first step is to do segmentation of CT medical images (DICOM) and to generate a surface mesh files (STL). Each STL file presents a different layer of human head with different material properties (brain, CSF, different layers of the skull bone, skin, etc.). The next steps are to make tetrahedral mesh from obtained STL files, to define FE model boundary conditions and to solve FE equations. This tool uses PAK solver, which is the open source software implemented in SIFEM FP7 project, for calculations of the head vibration. Purpose of this tool is to show impact of the bone conduction sound of the head on the hearing system and to estimate matching of obtained results with experimental measurements.

  16. Hand-transmitted vibration and biodynamic response of the human hand-arm: a critical review.

    PubMed

    Dong, R G; Rakheja, S; Schopper, A W; Han, B; Smutz, W P

    2001-01-01

    Hand-arm vibration syndrome (HAVS) has been associated with prolonged exposure to vibration transmitted to the human hand-arm system from hand-held power tools, vibrating machines, or hand-held vibrating workpieces. The biodynamic response of the human hand and arm to hand transmitted vibration (HTV) forms an essential basis for effective evaluations of exposures, vibration-attenuation mechanisms, and potential injury mechanisms. The biodynamic response to HTV and its relationship to HAVS are critically reviewed and discussed to highlight the advances and the need for further research. In view of its strong dependence on the nature of HTV and the lack of general agreement on the characteristics of HTV, the reported studies are first reviewed to enhance an understanding of HTV and related issues. The characteristics of HTV and relevant unresolved issues are discussed on the basis of measured data, proposed standards, and measurement methods, while the need for further developments in measurement systems is emphasized. The studies on biodynamic response and their findings are grouped into four categories based on the methodology used and the objective. These include studies on (1) through-the-hand-arm response, expressed in terms of vibration transmissibility; (2) to-the-hand response, expressed in terms of the force-motion relationship of the hand-arm system; (3) to-the-hand biodynamic response function, expressed in terms of vibration energy absorption; and (4) computer modeling of the biodynamic response characteristics.

  17. OVMS: the optical path difference and vibration monitoring system for the LBT and its interferometers

    NASA Astrophysics Data System (ADS)

    Kürster, M.; Bertram, T.; Borelli, J. L.; Brix, M.; Gässler, W.; Herbst, T. M.; Naranjo, V.; Pott, J.-U.; Trowitzsch, J.; Connors, T. E.; Hinz, P. M.; McMahon, T. J.; Ashby, D. S.; Brynnel, J. G.; Cushing, N. J.; Edgin, T.; Esguerra, J. D.; Green, R. F.; Kraus, J.; Little, J.; Beckmann, U.; Weigelt, G. P.

    2010-07-01

    Characterisation, mitigation and correction of telescope vibrations have proven to be crucial for the performance of astronomical infrared interferometers. The project teams of the interferometers for the LBT, LINC-NIRVANA and LBTI, and LBT Observatory (LBTO) have embarked on a joint effort to implement an accelerometer-based vibration measurement system distributed over the optical elements of the LBT. OVMS, the Optical Path Difference and Vibration Monitoring System will serve to (i) ensure conditions suitable for adaptive optics (AO) and interferometric (IF) observations and (ii) utilize vibration information, converted into tip-tilt and optical path difference data, in the control strategies of the LBT adaptive secondary mirrors and the beam combining interferometers. The system hardware is mainly developed by Steward Observatory's LBTI team and its installation at the LBT is underway. The OVMS software development and associated computer infrastructure is the responsibility of the LINC-NIRVANA team at MPIA Heidelberg. Initially, the OVMS will fill a data archive provided by LBTO that will be used to study vibration data and correlate them with telescope movements and environmental parameters thereby identifiying sources of vibrations and to eliminate or mitigate them. Data display tools will help LBTO staff to keep vibrations within predefined thresholds for quiet conditions for AO and IF observations. Later-on real-time data from the OVMS will be fed into the control loops of the AO systems and IF instruments in order to permit the correction of vibration signals with frequencies up to 450 Hz.

  18. Dose-response relationship between hand-transmitted vibration and hand-arm vibration syndrome in a tropical environment.

    PubMed

    Su, Anselm Ting; Maeda, Setsuo; Fukumoto, Jin; Darus, Azlan; Hoe, Victor C W; Miyai, Nobuyuki; Isahak, Marzuki; Takemura, Shigeki; Bulgiba, Awang; Yoshimasu, Kouichi; Miyashita, Kazuhisa

    2013-07-01

    The dose-response relationship for hand-transmitted vibration has been investigated extensively in temperate environments. Since the clinical features of hand-arm vibration syndrome (HAVS) differ between the temperate and tropical environment, we conducted this study to investigate the dose-response relationship of HAVS in a tropical environment. A total of 173 male construction, forestry and automobile manufacturing plant workers in Malaysia were recruited into this study between August 2011 and 2012. The participants were interviewed for history of vibration exposure and HAVS symptoms, followed by hand functions evaluation and vibration measurement. Three types of vibration doses-lifetime vibration dose (LVD), total operating time (TOT) and cumulative exposure index (CEI)-were calculated and its log values were regressed against the symptoms of HAVS. The correlation between each vibration exposure dose and the hand function evaluation results was obtained. The adjusted prevalence ratio for finger tingling and numbness was 3.34 (95% CI 1.27 to 8.98) for subjects with lnLVD≥20 ln m(2) s(-4) against those <16 ln m(2) s(-4). Similar dose-response pattern was found for CEI but not for TOT. No subject reported white finger. The prevalence of finger coldness did not increase with any of the vibration doses. Vibrotactile perception thresholds correlated moderately with lnLVD and lnCEI. The dose-response relationship of HAVS in a tropical environment is valid for finger tingling and numbness. The LVD and CEI are more useful than TOT when evaluating the dose-response pattern of a heterogeneous group of vibratory tools workers.

  19. Whole body vibration training improves vibration perception threshold in healthy young adults: A randomized clinical trial pilot study.

    PubMed

    Hernandez-Mocholi, M A; Dominguez-Muñoz, F J; Corzo, H; Silva, S Cs; Adsuar, J C; Gusi, N

    2016-03-01

    Loss of foot sensitivity is a relevant parameter to assess and prevent in several diseases. It is crucial to determine the vibro-tactile sensitivity threshold response to acute conditions to explore innovative monitor tools and interventions to prevent and treat this challenge. The aims were: 1) to analyze the acute effects of a single whole body vibration session (4min-18Hz-4mm) on vibro-tactile perception threshold in healthy young adults. 2) to analyze the 48 hours effects of 3 whole body vibration sessions on vibro-tactile perception threshold in healthy young adults. A randomized controlled clinical trial over 3 sessions of whole body vibration intervention or 3 sessions of placebo intervention. Twenty-eight healthy young adults were included: 11 experimental group and 12 placebo group. The experimental group performed 3 sessions of WBV while the placebo group performed 3 sessions of placebo intervention. The vibro-tactile threshold increased right after a single WBV session in comparison with placebo. Nevertheless, after 3 whole body vibration sessions and 48 hours, the threshold decreased to values lower than the initial. The acute response of the vibro-tactile threshold to one whole body vibration session increased, but the 48 hours short-term response of this threshold decreased in healthy young adults.

  20. Investigation of PDC bit failure base on stick-slip vibration analysis of drilling string system plus drill bit

    NASA Astrophysics Data System (ADS)

    Huang, Zhiqiang; Xie, Dou; Xie, Bing; Zhang, Wenlin; Zhang, Fuxiao; He, Lei

    2018-03-01

    The undesired stick-slip vibration is the main source of PDC bit failure, such as tooth fracture and tooth loss. So, the study of PDC bit failure base on stick-slip vibration analysis is crucial to prolonging the service life of PDC bit and improving ROP (rate of penetration). For this purpose, a piecewise-smooth torsional model with 4-DOF (degree of freedom) of drilling string system plus PDC bit is proposed to simulate non-impact drilling. In this model, both the friction and cutting behaviors of PDC bit are innovatively introduced. The results reveal that PDC bit is easier to fail than other drilling tools due to the severer stick-slip vibration. Moreover, reducing WOB (weight on bit) and improving driving torque can effectively mitigate the stick-slip vibration of PDC bit. Therefore, PDC bit failure can be alleviated by optimizing drilling parameters. In addition, a new 4-DOF torsional model is established to simulate torsional impact drilling and the effect of torsional impact on PDC bit's stick-slip vibration is analyzed by use of an engineering example. It can be concluded that torsional impact can mitigate stick-slip vibration, prolonging the service life of PDC bit and improving drilling efficiency, which is consistent with the field experiment results.

  1. The NASA/industry Design Analysis Methods for Vibrations (DAMVIBS) program : Bell Helicopter Textron accomplishments

    NASA Technical Reports Server (NTRS)

    Cronkhite, James D.

    1993-01-01

    Accurate vibration prediction for helicopter airframes is needed to 'fly from the drawing board' without costly development testing to solve vibration problems. The principal analytical tool for vibration prediction within the U.S. helicopter industry is the NASTRAN finite element analysis. Under the NASA DAMVIBS research program, Bell conducted NASTRAN modeling, ground vibration testing, and correlations of both metallic (AH-1G) and composite (ACAP) airframes. The objectives of the program were to assess NASTRAN airframe vibration correlations, to investigate contributors to poor agreement, and to improve modeling techniques. In the past, there has been low confidence in higher frequency vibration prediction for helicopters that have multibladed rotors (three or more blades) with predominant excitation frequencies typically above 15 Hz. Bell's findings under the DAMVIBS program, discussed in this paper, included the following: (1) accuracy of finite element models (FEM) for composite and metallic airframes generally were found to be comparable; (2) more detail is needed in the FEM to improve higher frequency prediction; (3) secondary structure not normally included in the FEM can provide significant stiffening; (4) damping can significantly affect phase response at higher frequencies; and (5) future work is needed in the areas of determination of rotor-induced vibratory loads and optimization.

  2. Relationship between hand-arm vibration exposure and onset time for symptoms in a heavy engineering production workshop.

    PubMed

    Burström, Lage; Hagberg, Mats; Lundström, Ronnie; Nilsson, Tohr

    2006-06-01

    This study examined onset time for reported vascular and neurological symptoms in relation to the vibration load in a group of workers exposed to vibration. Information on the self-stated year for the first occurrence of symptoms was collected by means of questionnaires. During interviews data were obtained on self-stated estimations of daily exposure time, type of tool, and number of months or years with different exposures. The estimations of the vibration magnitudes of exposure were based on conducted measurements. From these data, the individual vibration exposure at the time of onset of symptoms was calculated. The incidence was 25.6 and 32.9 per 1000 exposure years for vascular and neurological symptoms, respectively, in the group of workers. The first onset of symptoms appeared after an average of 12 years of exposure. For the workers, the symptoms of vascular or neurological disorders started after about the same number of exposure years. The calculated accumulated acceleration correlated best with the onset time of symptoms. It was concluded that, since the workers' exposure to vibration was below the action level established in the European vibration directive, the results suggest that the action level is not a safe level for avoiding vascular and neurological symptoms.

  3. Computational and experimental investigation of free vibration and flutter of bridge decks

    NASA Astrophysics Data System (ADS)

    Helgedagsrud, Tore A.; Bazilevs, Yuri; Mathisen, Kjell M.; Øiseth, Ole A.

    2018-06-01

    A modified rigid-object formulation is developed, and employed as part of the fluid-object interaction modeling framework from Akkerman et al. (J Appl Mech 79(1):010905, 2012. https://doi.org/10.1115/1.4005072) to simulate free vibration and flutter of long-span bridges subjected to strong winds. To validate the numerical methodology, companion wind tunnel experiments have been conducted. The results show that the computational framework captures very precisely the aeroelastic behavior in terms of aerodynamic stiffness, damping and flutter characteristics. Considering its relative simplicity and accuracy, we conclude from our study that the proposed free-vibration simulation technique is a valuable tool in engineering design of long-span bridges.

  4. Energy Harvesting Devices Utilizing Resonance Vibration of Piezoelectric Buzzer

    NASA Astrophysics Data System (ADS)

    Ogawa, Toshio; Sugisawa, Ryosuke; Sakurada, Yuta; Aoshima, Hiroshi; Hikida, Masahito; Akaishi, Hiroshi

    2013-09-01

    A piezoelectric buzzer for energy harvesting was investigated. Although an external force was added to a buzzer, a lead zirconate titanate (PZT) unimorph in the buzzer, the ceramic disc diameter, thickness, and capacitance of which were respectively 14 mm, 0.2 mm, and 10 nF, generated resonance vibration. As a result, alternating voltages of around 30 V and a frequency of 5 kHz were observed. When the generated voltages were applied to a LED lamp, new devices such as a “night-view footwear” and a “piezo-walker” were developed. It was confirmed that the piezo-buzzer for energy harvesting utilizing resonance vibration is an effective tool for obtaining clean energy.

  5. An approach to optimal semi-active control of vibration energy harvesting based on MEMS

    NASA Astrophysics Data System (ADS)

    Rojas, Rafael A.; Carcaterra, Antonio

    2018-07-01

    In this paper the energy harvesting problem involving typical MEMS technology is reduced to an optimal control problem, where the objective function is the absorption of the maximum amount of energy in a given time interval from a vibrating environment. The interest here is to identify a physical upper bound for this energy storage. The mathematical tool is a new optimal control called Krotov's method, that has not yet been applied to engineering problems, except in quantum dynamics. This approach leads to identify new maximum bounds to the energy harvesting performance. Novel MEMS-based device control configurations for vibration energy harvesting are proposed with particular emphasis to piezoelectric, electromagnetic and capacitive circuits.

  6. Graphite fiber reinforced structure for supporting machine tools

    DOEpatents

    Knight, Jr., Charles E.; Kovach, Louis; Hurst, John S.

    1978-01-01

    Machine tools utilized in precision machine operations require tool support structures which exhibit minimal deflection, thermal expansion and vibration characteristics. The tool support structure of the present invention is a graphite fiber reinforced composite in which layers of the graphite fibers or yarn are disposed in a 0/90.degree. pattern and bonded together with an epoxy resin. The finished composite possesses a low coefficient of thermal expansion and a substantially greater elastic modulus, stiffness-to-weight ratio, and damping factor than a conventional steel tool support utilized in similar machining operations.

  7. Reusable Energy and Power Sources: Rechargeable Batteries

    ERIC Educational Resources Information Center

    Hsiung, Steve C.; Ritz, John M.

    2007-01-01

    Rechargeable batteries are very popular within consumer electronics. If one uses a cell phone or portable electric tool, she/he understands the need to have a reliable product and the need to remember to use the recharging systems that follow a cycle of charge/discharge. Rechargeable batteries are being called "green" energy sources. They are a…

  8. DARPA TRADES Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aguilo Valentin, Miguel Alejandro; Trujillo, Susie

    During calendar year 2017, Sandia National Laboratories (SNL) made strides towards developing an open portable design platform rich in highperformance computing (HPC) enabled modeling, analysis and synthesis tools. The main focus was to lay the foundations of the core interfaces that will enable plug-n-play insertion of synthesis optimization technologies in the areas of modeling, analysis and synthesis.

  9. 29 CFR 570.34 - Occupations minors 14 and 15 years of age are permitted to perform in retail, food service, and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., art work, work in advertising departments, window trimming, and comparative shopping; (3) Price...) Cashiering, selling, modeling, art work, work in advertising departments, window trimming, and comparative... or portable machines or tools driven by power and used or designed for cutting, shaping, forming...

  10. C-MORE Science Kits as a Classroom Learning Tool

    ERIC Educational Resources Information Center

    Foley, J. M.; Bruno, B. C.; Tolman, R. T.; Kagami, R. S.; Hsia, M. H.; Mayer, B.; Inazu, J. K.

    2013-01-01

    To support teachers in enhancing ocean literacy, the Center for Microbial Oceanography: Research and Education (C-MORE) has developed a series of portable, hands-on science kits on selected topics in oceanography. This paper provides an overview of kit content, describes how the kits were developed, and evaluates their efficacy as a curriculum…

  11. Assured Access/Mobile Computing Initiatives on Five University Campuses.

    ERIC Educational Resources Information Center

    Blurton, Craig; Chee, Yam San; Long, Phillip D.; Resmer, Mark; Runde, Craig

    Mobile computing and assured access are becoming popular terms to describe a growing number of university programs which take advantage of ubiquitous network access points and the portability of notebook computers to ensure all students have access to digital tools and resources. However, the implementation of such programs varies widely from…

  12. Evaluation of the RWEQ and SWEEP in simulating soil and PM10 loss from a portable wind tunnel

    USDA-ARS?s Scientific Manuscript database

    Wind erosion threatens sustainable agriculture and environmental quality in the Columbia Plateau region of the US Pacific Northwest. Wind erosion models such as Wind Erosion Prediction System (WEPS) and the Revised Wind Erosion Equation (RWEQ) have been developed as tools for identifying practices t...

  13. Versatile Desktop Experiment Module (DEMo) on Heat Transfer

    ERIC Educational Resources Information Center

    Minerick, Adrienne R.

    2010-01-01

    This paper outlines a new Desktop Experiment Module (DEMo) engineered for a chemical engineering junior-level Heat Transfer course. This new DEMo learning tool is versatile, fairly inexpensive, and portable such that it can be positioned on student desks throughout a classroom. The DEMo system can illustrate conduction of various materials,…

  14. The App Map: A Tool for Systematic Evaluation of Apps for Early Literacy Learning

    ERIC Educational Resources Information Center

    Israelson, Madeleine Heins

    2015-01-01

    As portable devices become increasingly available in elementary classrooms teachers are expected to use these new technologies to engage students in both traditional print-based literacy learning and digital literacies practices, such as multimodal composing. Teachers face the daunting task of integrating apps into their current research-based…

  15. The Bottomless File Box: Electronic Portfolios for Learning and Evaluation Purposes

    ERIC Educational Resources Information Center

    Jarrott, Shannon; Gambrel, Laura Eubanks

    2011-01-01

    Portfolios have been used for the past three decades in higher education for assessment of student competency and also as a reflection tool to assist student learning. Electronic portfolios, or ePortfolios, have additional benefits compared to paper portfolios in that they are easily accessible, portable, and sharable, and they are more…

  16. Bridging the Gap between Basic and Clinical Sciences: A Description of a Radiological Anatomy Course

    ERIC Educational Resources Information Center

    Torres, Anna; Staskiewicz, Grzegorz J.; Lisiecka, Justyna; Pietrzyk, Lukasz; Czekajlo, Michael; Arancibia, Carlos U.; Maciejewski, Ryszard; Torres, Kamil

    2016-01-01

    A wide variety of medical imaging techniques pervade modern medicine, and the changing portability and performance of tools like ultrasound imaging have brought these medical imaging techniques into the everyday practice of many specialties outside of radiology. However, proper interpretation of ultrasonographic and computed tomographic images…

  17. Assembly and Validation of a Colorimeter

    ERIC Educational Resources Information Center

    Hughes, Bill

    2013-01-01

    A low-cost and portable colorimeter kit has been designed and developed as an educational tool at Penn State University by Dr. Daniel Sykes for K-12 schools' integrated STEM learning. This scientific instrument allows students to learn how scientists utilize light as a means to study the chemical and physical properties of materials with an…

  18. Grid Visualization Tool

    NASA Technical Reports Server (NTRS)

    Chouinard, Caroline; Fisher, Forest; Estlin, Tara; Gaines, Daniel; Schaffer, Steven

    2005-01-01

    The Grid Visualization Tool (GVT) is a computer program for displaying the path of a mobile robotic explorer (rover) on a terrain map. The GVT reads a map-data file in either portable graymap (PGM) or portable pixmap (PPM) format, representing a gray-scale or color map image, respectively. The GVT also accepts input from path-planning and activity-planning software. From these inputs, the GVT generates a map overlaid with one or more rover path(s), waypoints, locations of targets to be explored, and/or target-status information (indicating success or failure in exploring each target). The display can also indicate different types of paths or path segments, such as the path actually traveled versus a planned path or the path traveled to the present position versus planned future movement along a path. The program provides for updating of the display in real time to facilitate visualization of progress. The size of the display and the map scale can be changed as desired by the user. The GVT was written in the C++ language using the Open Graphics Library (OpenGL) software. It has been compiled for both Sun Solaris and Linux operating systems.

  19. Illumination box and camera system

    DOEpatents

    Haas, Jeffrey S.; Kelly, Fredrick R.; Bushman, John F.; Wiefel, Michael H.; Jensen, Wayne A.; Klunder, Gregory L.

    2002-01-01

    A hand portable, field-deployable thin-layer chromatography (TLC) unit and a hand portable, battery-operated unit for development, illumination, and data acquisition of the TLC plates contain many miniaturized features that permit a large number of samples to be processed efficiently. The TLC unit includes a solvent tank, a holder for TLC plates, and a variety of tool chambers for storing TLC plates, solvent, and pipettes. After processing in the TLC unit, a TLC plate is positioned in a collapsible illumination box, where the box and a CCD camera are optically aligned for optimal pixel resolution of the CCD images of the TLC plate. The TLC system includes an improved development chamber for chemical development of TLC plates that prevents solvent overflow.

  20. Tool vibration detection with eddy current sensors in machining process and computation of stability lobes using fuzzy classifiers

    NASA Astrophysics Data System (ADS)

    Devillez, Arnaud; Dudzinski, Daniel

    2007-01-01

    Today the knowledge of a process is very important for engineers to find optimal combination of control parameters warranting productivity, quality and functioning without defects and failures. In our laboratory, we carry out research in the field of high speed machining with modelling, simulation and experimental approaches. The aim of our investigation is to develop a software allowing the cutting conditions optimisation to limit the number of predictive tests, and the process monitoring to prevent any trouble during machining operations. This software is based on models and experimental data sets which constitute the knowledge of the process. In this paper, we deal with the problem of vibrations occurring during a machining operation. These vibrations may cause some failures and defects to the process, like workpiece surface alteration and rapid tool wear. To measure on line the tool micro-movements, we equipped a lathe with a specific instrumentation using eddy current sensors. Obtained signals were correlated with surface finish and a signal processing algorithm was used to determine if a test is stable or unstable. Then, a fuzzy classification method was proposed to classify the tests in a space defined by the width of cut and the cutting speed. Finally, it was shown that the fuzzy classification takes into account of the measurements incertitude to compute the stability limit or stability lobes of the process.

Top