NASA Astrophysics Data System (ADS)
Uribe, J.; Aykac, M.; Baghaei, H.; Li, Hongdi; Wang, Yu; Liu, Yaqiang; Wong, V.; Xing, Tao; Ramirez, R.; Wong, Wai-Hoi
2003-06-01
Recent approvals by CMS (HCFA) for reimbursement of positron emission tomography (PET) scans fuels the rapid grow of the PET market, thus creating the need for more affordable dedicated PET scanners. The objective of the work presented here was the development of a BGO position-sensitive block with similar detector area (40 mm /spl times/ 40 mm) and same number of crystals (8 /spl times/ 8) as the block of a commercial BGO PET, using the less expensive photomultiplier quadrant sharing (PQS) technique. This block is coupled to four single-anode 40-mm diameter photomultipliers (PMT) instead of the 19-mm PMT used in a popular commercial BGO PET, and each PMT is shared by four adjacent detector blocks. Potentially, this design needs only 25% of the number of PMT used in the commercial BGO PET. In order not to waste the unused half-row of PMT at the edges of a detector panel/module when the module is made up solely of square blocks, an extended rectangular block has to be developed for the edge-blocks in the module, which maximized the use of the PMT and minimized the gap between modules. Only the extended block needs to be developed to derive the design for all the blocks in the module because the symmetric square block uses the same light-distributing partitions as those along the short side of the extended rectangular block. White-paint masks applied with accurate templates and airbrush were fine-tuned for every pair of adjacent crystals. The experimental block developed in this study provided good crystal-decoding. The composite energy spectrum of all 64 crystals showed a prominent photopeak. The worst crystal sitting in the air space between 4 round PMTs still has 60% of the signal pulse height as the best crystal. The average energy resolution was 21.8% for 511 keV gamma (range 17% - 28.7%) that compared well with the 22% - 44% measured with GE and CTI blocks. The image resolution provided by the PQS blocks is expected to be comparable to that of commercial BGO PETs as similar size crystals were decoded.
Characterization of the LBNL PEM Camera
NASA Astrophysics Data System (ADS)
Wang, G.-C.; Huber, J. S.; Moses, W. W.; Qi, J.; Choong, W.-S.
2006-06-01
We present the tomographic images and performance measurements of the LBNL positron emission mammography (PEM) camera, a specially designed positron emission tomography (PET) camera that utilizes PET detector modules with depth of interaction measurement capability to achieve both high sensitivity and high resolution for breast cancer detection. The camera currently consists of 24 detector modules positioned as four detector banks to cover a rectangular patient port that is 8.2/spl times/6 cm/sup 2/ with a 5 cm axial extent. Each LBNL PEM detector module consists of 64 3/spl times/3/spl times/30 mm/sup 3/ LSO crystals coupled to a single photomultiplier tube (PMT) and an 8/spl times/8 silicon photodiode array (PD). The PMT provides accurate timing, the PD identifies the crystal of interaction, the sum of the PD and PMT signals (PD+PMT) provides the total energy, and the PD/(PD+PMT) ratio determines the depth of interaction. The performance of the camera has been evaluated by imaging various phantoms. The full-width-at-half-maximum (FWHM) spatial resolution changes slightly from 1.9 mm to 2.1 mm when measured at the center and corner of the field of the view, respectively, using a 6 ns coincidence timing window and a 300-750 keV energy window. With the same setup, the peak sensitivity of the camera is 1.83 kcps//spl mu/Ci.
Evaluation of the Timing Properties of a High Quantum Efficiency Photomultiplier Tube
NASA Astrophysics Data System (ADS)
Peng, Qiyu; Choong, Woon-Seng; Moses, W. William
2013-10-01
We measured the timing resolution of 189 R9800-100 photomultiplier tubes (PMTs), which are a SBA (Super Bialkali, high quantum efficiency) variant of the R9800 high-performance PMT manufactured by Hamamatsu Photonics, and correlated their timing resolutions with various measures of PMT performance, namely Cathode Luminous Sensitivity (CLS), Anode Luminous Sensitivity (ALS), Gain times Collection Efficiency (GCE), Cathode Blue Sensitivity Index (CBSI), Anode Blue Sensitivity Index (ABSI) and dark current. The correlation results show: (1) strong correlations between timing resolution and ALS, ABSI, and GCE; (2) moderate correlations between timing resolution and CBSI; and (3) weak or no correlations between timing resolution and dark current and CLS. The results disclosed that all three measures that include data collected from the anode (ALS, ABSI, and GCE) affect the timing resolution more than either of the two measures that only include photocathode data (CBSI and CLS). We conclude that: (1) the photocathode Quantum Efficiency (QE) and the product of the Gain and the Collection Efficiency (GCE) are the two dominant factors that affect the timing resolution, (2) the GCE variation affects the timing resolution more than the QE variation in the R9800 PMT, and (3) the performance depends on photocathode position.
Coincidence ion imaging with a fast frame camera
NASA Astrophysics Data System (ADS)
Lee, Suk Kyoung; Cudry, Fadia; Lin, Yun Fei; Lingenfelter, Steven; Winney, Alexander H.; Fan, Lin; Li, Wen
2014-12-01
A new time- and position-sensitive particle detection system based on a fast frame CMOS (complementary metal-oxide semiconductors) camera is developed for coincidence ion imaging. The system is composed of four major components: a conventional microchannel plate/phosphor screen ion imager, a fast frame CMOS camera, a single anode photomultiplier tube (PMT), and a high-speed digitizer. The system collects the positional information of ions from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of a PMT processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of ion spots on each camera frame with the peak heights on the corresponding time-of-flight spectrum of a PMT. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide.
Turner, Andrew G; Ong, Cheryl-Lynn Y; Djoko, Karrera Y; West, Nicholas P; Davies, Mark R; McEwan, Alastair G; Walker, Mark J
2017-06-01
Streptococcus pyogenes (group A Streptococcus [GAS]) is an obligate human pathogen responsible for a broad spectrum of human disease. GAS has a requirement for metal homeostasis within the human host and, as such, tightly modulates metal uptake and efflux during infection. Metal acquisition systems are required to combat metal sequestration by the host, while metal efflux systems are essential to protect against metal overload poisoning. Here, we investigated the function of PmtA ( P erR-regulated m etal t ransporter A ), a P 1B-4 -type ATPase efflux pump, in invasive GAS M1T1 strain 5448. We reveal that PmtA functions as a ferrous iron [Fe(II)] efflux system. In the presence of high Fe(II) concentrations, the 5448Δ pmtA deletion mutant exhibited diminished growth and accumulated 5-fold-higher levels of intracellular Fe(II) than did the wild type and the complemented mutant. The 5448Δ pmtA deletion mutant also showed enhanced susceptibility to killing by the Fe-dependent antibiotic streptonigrin as well as increased sensitivity to hydrogen peroxide and superoxide. We suggest that the PerR-mediated control of Fe(II) efflux by PmtA is important for bacterial defense against oxidative stress. PmtA represents an exemplar for an Fe(II) efflux system in a host-adapted Gram-positive bacterial pathogen. Copyright © 2017 American Society for Microbiology.
Coincidence ion imaging with a fast frame camera
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Suk Kyoung; Cudry, Fadia; Lin, Yun Fei
2014-12-15
A new time- and position-sensitive particle detection system based on a fast frame CMOS (complementary metal-oxide semiconductors) camera is developed for coincidence ion imaging. The system is composed of four major components: a conventional microchannel plate/phosphor screen ion imager, a fast frame CMOS camera, a single anode photomultiplier tube (PMT), and a high-speed digitizer. The system collects the positional information of ions from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of a PMT processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of ion spots onmore » each camera frame with the peak heights on the corresponding time-of-flight spectrum of a PMT. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide.« less
Yang, Jichun; Wang, Qiong; Zhang, Minhui; Zhang, Shuming; Zhang, Lei
2015-11-15
In this study, a simple, rapid, sensitive and environmentally friendly electroanalytical detection method for pyrimethanil (PMT) was developed, which was based on multi-walled carbon nanotubes (MWCNTs) and ionic liquids (IL) 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF6]) modified glassy carbon electrode (GCE). MWCNTs-IL modified electrode significantly enhanced the oxidation peak current of PMT by combining the excellent electrochemical properties of MWCNTs and IL, suggesting that the modified electrode can remarkably improve the sensitivity of PMT detection. Under the optimum conditions, this electrochemical sensor exhibited a linear concentration range for PMT of 1.0 × 10(-7)-1.0 × 10(-4) mol L(-1) and the detection limit was 1.6 × 10(-8) mol L(-1) (S/N = 3). The fabricated electrode showed good reproducibility, stability and anti-interference, and also it was successfully employed to detect PMT in real samples. Copyright © 2015 Elsevier Ltd. All rights reserved.
The nucleus is an intracellular propagator of tensile forces in NIH 3T3 fibroblasts
Alam, Samer G.; Lovett, David; Kim, Dae In; Roux, Kyle J.; Dickinson, Richard B.; Lele, Tanmay P.
2015-01-01
ABSTRACT Nuclear positioning is a crucial cell function, but how a migrating cell positions its nucleus is not understood. Using traction-force microscopy, we found that the position of the nucleus in migrating fibroblasts closely coincided with the center point of the traction-force balance, called the point of maximum tension (PMT). Positioning of the nucleus close to the PMT required nucleus–cytoskeleton connections through linker of nucleoskeleton-to-cytoskeleton (LINC) complexes. Although the nucleus briefly lagged behind the PMT following spontaneous detachment of the uropod during migration, the nucleus quickly repositioned to the PMT within a few minutes. Moreover, traction-generating spontaneous protrusions deformed the nearby nucleus surface to pull the nuclear centroid toward the new PMT, and subsequent retraction of these protrusions relaxed the nuclear deformation and restored the nucleus to its original position. We propose that the protruding or retracting cell boundary transmits a force to the surface of the nucleus through the intervening cytoskeletal network connected by the LINC complexes, and that these forces help to position the nucleus centrally and allow the nucleus to efficiently propagate traction forces across the length of the cell during migration. PMID:25908852
A novel compensation method for the anode gain non-uniformity of multi-anode photomultiplier tubes
NASA Astrophysics Data System (ADS)
Lee, Chan Mi; Kwon, Sun Il; Ko, Guen Bae; Ito, Mikiko; Yoon, Hyun Suk; Lee, Dong Soo; Jong Hong, Seong; Lee, Jae Sung
2012-01-01
The position-sensitive multi-anode photomultiplier tube (MA-PMT) is widely used in high-resolution scintillation detectors. However, the anode gain non-uniformity of this device is a limiting factor that degrades the intrinsic performance of the detector module. The aim of this work was to develop a gain compensation method for the MA-PMT and evaluate the resulting enhancement in the performance of the detector. The method employs a circuit that is composed only of resistors and is placed between the MA-PMT and a resistive charge division network (RCN) used for position encoding. The goal of the circuit is to divide the output current from each anode, so the same current flows into the RCN regardless of the anode gain. The current division is controlled by the combination of a fixed-value series resistor with an output impedance that is much larger than the input impedance of the RCN, and a parallel resistor, which detours part of the current to ground. PSpice simulations of the compensation circuit and the RCN were performed to determine optimal values for the compensation resistors when used with Hamamatsu H8500 MA-PMTs. The intrinsic characteristics of a detector module consisting of this MA-PMT and a lutetium-gadolinium-oxyorthosilicate (LGSO) crystal array were tested with and without the gain compensation method. In simulation, the average coefficient of variation and max/min ratio decreased from 15.7% to 2.7% and 2.0 to 1.2, respectively. In the flood map of the LGSO-H8500 detector, the uniformity of the photopeak position for individual crystals and the energy resolution were much improved. The feasibility of the method was shown by applying it to an octagonal prototype positron emission tomography scanner.
Low Power Photomultiplier Tube Circuit And Method Thereor
Bochenski, Edwin B.; Skinner, Jack L.; Dentinger, Paul M.; Lindblom, Scott C.
2006-04-18
An electrical circuit for a photomultiplier tube (PMT) is disclosed that reduces power consumption to a point where the PMT may be powered for extended periods with a battery. More specifically, the invention concerns a PMT circuit comprising a low leakage switch and a high voltage capacitor positioned between a resistive divider and each of the PMT dynodes, and a low power control scheme for recharging the capacitors.
PMT waveform modeling at the Daya Bay experiment
NASA Astrophysics Data System (ADS)
Sören, Jetter; Dan, Dwyer; Jiang, Wen-Qi; Liu, Da-Wei; Wang, Yi-Fang; Wang, Zhi-Min; Wen, Liang-Jian
2012-08-01
Detailed measurements of Hamamatsu R5912 photomultiplier signals are presented, including the single photoelectron charge response, waveform shape, nonlinearity, saturation, overshoot, oscillation, prepulsing, and afterpulsing. The results were used to build a detailed model of the PMT signal characteristics over a wide range of light intensities. Including the PMT model in simulated Daya Bay particle interactions shows no significant systematic effects that are detrimental to the experimental sensitivity.
Psychosocial correlates of HIV protection motivation among black adolescents in Venda, South Africa.
Boer, Henk; Mashamba, M Tshilidzi
2005-12-01
We assessed the usefulness of the theory of planned behavior (TPB) and protection motivation theory (PMT) to predict intended condom use among 201 adolescents from Venda, South Africa. Results indicated that both the TPB and the PMT could significantly predict intended condom use, although the level of explained variance was limited. Hierarchical regression analysis indicated that there was considerable overlap between the TPB and the PMT in predicting condom use intention. In the regression analysis that used both the TPB and the PMT variables subjective norms and response efficacy were positively related to intended condom use. The results indicated that both the TPB and the PMT were valuable in explaining intended condom use among African adolescents. The TPB made clear that the social environment is an important contextual factor, whereas the PMT made clear that response efficacy is positively related to condom use intention. The results of this study indicated that social cognition models have some value in the analysis of condom use intention of African adolescents, but the role of other factors like myths about condoms should be further examined.
Yamada, Yuichi; Kinoshita, Izumi; Kenichi, Kohashi; Yamamoto, Hidetaka; Iwasaki, Takeshi; Otsuka, Hiroshi; Yoshimoto, Masato; Ishihara, Shin; Toda, Yu; Kuma, Yuki; Setsu, Nokitaka; Koga, Yuki; Honda, Yumi; Inoue, Takeshi; Yanai, Hiroyuki; Yamashita, Kyoko; Ito, Ichiro; Takahashi, Mitsuru; Ohga, Shouichi; Furue, Masutaka; Nakashima, Yasuharu; Oda, Yoshinao
2018-02-01
Phosphaturic mesenchymal tumour, mixed connective tissue variant (PMT-MCT), is a tumour of uncertain differentiation, characterised by 'smudgy/grungy' calcification and vitamin D-resistant phosphaturic osteomalacia. Fibroblast growth factor (FGF)23 is recognised as a reliable marker of PMT-MCT, but quantitative evaluation has never been performed. We reviewed cases of tumour-associated osteomalacia or histologically definitive PMT-MCT without osteomalacia using histological, immunohistochemical and genetic methods and evaluated the diagnostic significance of these findings. A total of 19 tumours from 14 cases diagnosed previously as PMT-MCT were retrieved, on which immunohistochemical staining, reverse transcription-polymerase chain reaction (RT-PCR) and fluorescence in-situ hybridisation (FISH) analysis were performed. Histologically, fibrous capsule, calcification and giant cell reaction tended to be observed in soft-tissue PMT-MCT, while PMT-MCT of bone and multiple PMT-MCT showed an infiltrative growth pattern. The immunohistochemical results were as follows: the tumour cells were positive for FGF23 (nine of 12, 75%), FGFR1 (11 of 11, 100%), CD56 (12 of 14, 85.7%) and E26 oncogene homologue (ERG) (5 of 13, 38.4%). The sole malignant tumour was positive for p53. FGF23 mRNA was detected in seven of 14 formalin-fixed paraffin-embedded (FFPE) specimens and all five frozen specimens by RT-PCR. The level of FGF23 mRNA, which was determined by real-time PCR, varied among the phosphaturic cases. Two of 17 tumours were positive for FGFR1 gene rearrangement. It was considered that PMT-MCT is a histopathological entity with or without phosphaturia, with varying levels of FGF23 mRNA, and with or without fibronectin 1 (FN1)-FGFR1 fusion gene. The authors propose that the histology of PMT-MCT differs depending on its location, such as bone or soft tissue, which could complicate the differential diagnosis. © 2017 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Ito, Mikiko; Lee, Jae Sung; Park, Min-Jae; Sim, Kwang-Souk; Jong Hong, Seong
2010-07-01
PET detectors with depth-of-interaction (DOI) encoding capability allow high spatial resolution and high sensitivity to be achieved simultaneously. To obtain DOI information from a mono-layer array of scintillation crystals using a single-ended readout, the authors devised a method based on light spreading within a crystal array and performed Monte Carlo simulations with individual scintillation photon tracking to prove the concept. A scintillation crystal array model was constructed using a grid method. Conventional grids are constructed using comb-shaped reflector strips with rectangular teeth to isolate scintillation crystals optically. However, the authors propose the use of triangularly shaped teeth, such that scintillation photons spread only in the x-direction in the upper halves of crystals and in the y-direction in lower halves. DOI positions can be estimated by considering the extent of two-dimensional light dispersion, which can be determined from the multiple anode outputs of a position-sensitive PMT placed under the crystal array. In the main simulation, a crystal block consisting of a 29 × 29 array of 1.5 mm × 1.5 mm × 20 mm crystals and a multi-anode PMT with 16 × 16 pixels were used. The effects of crystal size and non-uniform PMT output gain were also explored by simulation. The DOI resolution estimated for 1.5 × 1.5 × 20 mm3 crystals was 2.16 mm on average. Although the flood map was depth dependent, each crystal was well identified at all depths when a corner of the crystal array was irradiated with 511 keV gamma rays (peak-to-valley ratio ~9:1). DOI resolution was better than 3 mm up to a crystal length of 28 mm with a 1.5 × 1.5 mm2 or 2.0 × 2.0 mm2 crystal surface area. The devised light-sharing method allowed excellent DOI resolutions to be obtained without the use of dual-ended readout or multiple crystal arrays.
Proof of feasibility of the Vacuum Silicon PhotoMultiplier Tube (VSiPMT)
NASA Astrophysics Data System (ADS)
Barbarino, G.; Campajola, L.; de Asmundis, R.; De Rosa, G.; Fiorillo, G.; Migliozzi, P.; Barbato, F. C. T.; Mollo, C. M.; Russo, A.; Vivolo, D.
2013-04-01
The Vacuum Silicon PhotoMultiplier Tube (VSiPMT) is an innovative design we propose for a modern hybrid photodetector based on the combination of a Silicon PhotoMultiplier (SiPM) with a hemispherical vacuum glass PMT standard envelope. The basic idea is to replace the classical dynode chain of a PMT with a SiPM, which acts as an electron multiplying detector. Such a solution will match the goal of a large photocathode sensitive area with the performances of a SiPM. This will lead to many advantages such as lower power consumption, mild sensitivity to magnetic fields and high quantum efficiency. The feasibility of this idea has been throughly studied both from a theoretical and experimental point of view. As a first step we performed the full characterization of a special non-windowed Hamamatsu MPPC with a laser source. The response of the SiPM to an electron beam was studied as a function of the energy and of the incident angle by means of a Geant4-based simulation. In this paper we present the preliminary results of the characterization of the SiPM with an electron source and we discuss how the development of next generation SiPMs will overcome the main weaknesses of VSiPMT, such as relatively low PDE and high photocathode voltage.
Wu, Heyu; Tai, Yuan-Chuan
2011-09-07
To meet the growing demand for functional imaging technology for use in studying plant biology, we are developing a novel technique that permits simultaneous imaging of escaped positrons and coincidence gammas from annihilation of positrons within an intake leaf. The multi-modality imaging system will include two planar detectors: one is a typical PET detector array and the other is a phoswich imaging detector that detects both beta and gamma. The novel phoswich detector is made of a plastic scintillator, a lutetium oxyorthosilicate (LSO) array, and a position sensitive photomultiplier tube (PS-PMT). The plastic scintillator serves as a beta detector, while the LSO array serves as a gamma detector and light guide that couples scintillation light from the plastic detector to the PMT. In our prototype, the PMT signal was fed into the Siemens QuickSilver electronics to achieve shaping and waveform sampling. Pulse-shape discrimination based on the detectors' decay times (2.1 ns for plastic and 40 ns for LSO) was used to differentiate beta and gamma events using the common PMT signals. Using our prototype phoswich detector, we simultaneously measured a beta image and gamma events (in single mode). The beta image showed a resolution of 1.6 mm full-width-at-half-maximum using F-18 line sources. Because this shows promise for plant-scale imaging, our future plans include development of a fully functional simultaneous beta-and-coincidence-gamma imager with sub-millimeter resolution imaging capability for both modalities.
Fusion neutron detector for time-of-flight measurements in z-pinch and plasma focus experiments.
Klir, D; Kravarik, J; Kubes, P; Rezac, K; Litseva, E; Tomaszewski, K; Karpinski, L; Paduch, M; Scholz, M
2011-03-01
We have developed and tested sensitive neutron detectors for neutron time-of-flight measurements in z-pinch and plasma focus experiments with neutron emission times in tens of nanoseconds and with neutron yields between 10(6) and 10(12) per one shot. The neutron detectors are composed of a BC-408 fast plastic scintillator and Hamamatsu H1949-51 photomultiplier tube (PMT). During the calibration procedure, a PMT delay was determined for various operating voltages. The temporal resolution of the neutron detector was measured for the most commonly used PMT voltage of 1.4 kV. At the PF-1000 plasma focus, a novel method of the acquisition of a pulse height distribution has been used. This pulse height analysis enabled to determine the single neutron sensitivity for various neutron energies and to calibrate the neutron detector for absolute neutron yields at about 2.45 MeV.
NASA Astrophysics Data System (ADS)
Morozov, A.; Defendi, I.; Engels, R.; Fraga, F. A. F.; Fraga, M. M. F. R.; Guerard, B.; Jurkovic, M.; Kemmerling, G.; Manzin, G.; Margato, L. M. S.; Niko, H.; Pereira, L.; Petrillo, C.; Peyaud, A.; Piscitelli, F.; Raspino, D.; Rhodes, N. J.; Sacchetti, F.; Schooneveld, E. M.; Van Esch, P.; Zeitelhack, K.
2012-08-01
A custom and fully interactive simulation package ANTS (Anger-camera type Neutron detector: Toolkit for Simulations) has been developed to optimize the design and operation conditions of secondary scintillation Anger-camera type gaseous detectors for thermal neutron imaging. The simulation code accounts for all physical processes related to the neutron capture, energy deposition pattern, drift of electrons of the primary ionization and secondary scintillation. The photons are traced considering the wavelength-resolved refraction and transmission of the output window. Photo-detection accounts for the wavelength-resolved quantum efficiency, angular response, area sensitivity, gain and single-photoelectron spectra of the photomultipliers (PMTs). The package allows for several geometrical shapes of the PMT photocathode (round, hexagonal and square) and offers a flexible PMT array configuration: up to 100 PMTs in a custom arrangement with the square or hexagonal packing. Several read-out patterns of the PMT array are implemented. Reconstruction of the neutron capture position (projection on the plane of the light emission) is performed using the center of gravity, maximum likelihood or weighted least squares algorithm. Simulation results reproduce well the preliminary results obtained with a small-scale detector prototype. ANTS executables can be downloaded from http://coimbra.lip.pt/~andrei/.
Yan, Yaqiong; Jacques-Tiura, Angela J.; Chen, Xinguang; Xie, Nianhua; Chen, Jing; Yang, Niannian; Gong, Jie; MacDonell, Karen Kolmodin
2013-01-01
Reducing tobacco use among adolescents in China represents a significant challenge for global tobacco control. Existing behavioral theories developed in the West – such as the Protection Motivation Theory (PMT) – may be useful tools to help tackle this challenge. We examined the relationships between PMT factors and self-reported cigarette smoking behavior and intention among a random sample of vocational high school students (N = 553) in Wuhan, China. Tobacco-related perceptions were assessed using the PMT Scale for Adolescent Smoking. Among the total sample, 45% had initiated cigarette smoking, and 25% smoked in the past month. Among those who never smoked, 15% indicated being likely or very likely to smoke in a year. Multiple regression modeling analysis indicated the significance of the seven PMT constructs, the four PMT perceptions and the two PMT pathways in predicting intention to smoke and actual smoking behavior. Overall, perceived rewards of smoking, especially intrinsic rewards, were consistently positively related to smoking intentions and behavior, and self-efficacy to avoid smoking was negatively related to smoking. The current study suggests the utility of PMT for further research examining adolescent smoking. PMT-based smoking prevention and clinical smoking cessation intervention programs should focus more on adolescents’ perceived rewards from smoking and perceived efficacy of not smoking to reduce their intention to and actual use of tobacco. PMID:24157424
Yan, Yaqiong; Jacques-Tiura, Angela J; Chen, Xinguang; Xie, Nianhua; Chen, Jing; Yang, Niannian; Gong, Jie; Macdonell, Karen Kolmodin
2014-01-01
Reducing tobacco use among adolescents in China represents a significant challenge for global tobacco control. Existing behavioral theories developed in the West - such as the Protection Motivation Theory (PMT) - may be useful tools to help tackle this challenge. We examined the relationships between PMT factors and self-reported cigarette smoking behavior and intention among a random sample of vocational high school students (N=553) in Wuhan, China. Tobacco-related perceptions were assessed using the PMT Scale for Adolescent Smoking. Among the total sample, 45% had initiated cigarette smoking, and 25% smoked in the past month. Among those who never smoked, 15% indicated being likely or very likely to smoke in a year. Multiple regression modeling analysis indicated the significance of the seven PMT constructs, the four PMT perceptions and the two PMT pathways in predicting intention to smoke and actual smoking behavior. Overall, perceived rewards of smoking, especially intrinsic rewards, were consistently positively related to smoking intentions and behavior, and self-efficacy to avoid smoking was negatively related to smoking. The current study suggests the utility of PMT for further research examining adolescent smoking. PMT-based smoking prevention and clinical smoking cessation intervention programs should focus more on adolescents' perceived rewards from smoking and perceived efficacy of not smoking to reduce their intention to and actual use of tobacco. © 2013.
Postmortem time estimation using body temperature and a finite-element computer model.
den Hartog, Emiel A; Lotens, Wouter A
2004-09-01
In the Netherlands most murder victims are found 2-24 h after the crime. During this period, body temperature decrease is the most reliable method to estimate the postmortem time (PMT). Recently, two murder cases were analysed in which currently available methods did not provide a sufficiently reliable estimate of the PMT. In both cases a study was performed to verify the statements of suspects. For this purpose a finite-element computer model was developed that simulates a human torso and its clothing. With this model, changes to the body and the environment can also be modelled; this was very relevant in one of the cases, as the body had been in the presence of a small fire. In both cases it was possible to falsify the statements of the suspects by improving the accuracy of the PMT estimate. The estimated PMT in both cases was within the range of Henssge's model. The standard deviation of the PMT estimate was 35 min in the first case and 45 min in the second case, compared to 168 min (2.8 h) in Henssge's model. In conclusion, the model as presented here can have additional value for improving the accuracy of the PMT estimate. In contrast to the simple model of Henssge, the current model allows for increased accuracy when more detailed information is available. Moreover, the sensitivity of the predicted PMT for uncertainty in the circumstances can be studied, which is crucial to the confidence of the judge in the results.
Pasteurella multocida Toxin Manipulates T Cell Differentiation
Hildebrand, Dagmar; Heeg, Klaus; Kubatzky, Katharina F.
2015-01-01
Pasteurella multocida causes various diseases in a broad range of wild and domestic animals. Toxigenic strains of the serotypes A and D produce an AB protein toxin named Pasteurella multocida toxin (PMT). PMT constitutively activates the heterotrimeric G protein subunits Gαq, Gα13, and Gαi through deamidation of a glutamine residue, which results in cytoskeletal rearrangements as well as increased proliferation and survival of the host cell. In human monocytes, PMT alters the lipopolysaccharide (LPS)-induced activation toward a phenotype that suppresses T cell activation. Here we describe that the toxin also modulates CD4-positive T helper (Th) cells directly. PMT amplifies the expansion of Th cells through enhanced cell cycle progression and suppression of apoptosis and manipulates the differentiation of Th subclasses through activation of Signal Transducers and Activators of Transcription (STAT) family members and induction of subtype-specific master transcription factors. A large population of toxin-treated T cells is double-positive for Foxp3 and RORγt, the transcription factors expressed by Treg and Th17 cells, respectively. This suggests that these cells could have the potential to turn into Th17 cells or suppressive Treg cells. However, in terms of function, the PMT-differentiated cells behave as inflammatory Th17 cells that produce IL-17 and trigger T cell proliferation. PMID:26635744
A Lower-Cost High-Resolution LYSO Detector Development for Positron Emission Mammography (PEM)
Ramirez, Rocio A.; Zhang, Yuxuan; Liu, Shitao; Li, Hongdi; Baghaei, Hossain; An, Shaohui; Wang, Chao; Jan, Meei-Ling; Wong, Wai-Hoi
2010-01-01
In photomultiplier-quadrant-sharing (PQS) geometry for positron emission tomography applications, each PMT is shared by four blocks and each detector block is optically coupled to four round PMTs. Although this design reduces the cost of high-resolution PET systems, when the camera consists of detector panels that are made up of square blocks, half of the PMT’s sensitive window remains unused at the detector panel edge. Our goal was to develop a LYSO detector panel which minimizes the unused portion of the PMTs for a low-cost, high-resolution, and high-sensitivity positron emission mammography (PEM) camera. We modified the PQS design by using elongated blocks at panel edges and square blocks in the inner area. For elongated blocks, symmetric and asymmetrical reflector patterns were developed and PQS and PMT-half-sharing (PHS) arrangements were implemented in order to obtain a suitable decoding. The packing fraction was 96.3% for asymmetric block and 95.5% for symmetric block. Both of the blocks have excellent decoding capability with all crystals clearly identified, 156 for asymmetric and 144 for symmetric and peak-to-valley ratio of 3.0 and 2.3 respectively. The average energy resolution was 14.2% for the asymmetric block and 13.1% for the symmetric block. Using a modified PQS geometry and asymmetric block design, we reduced the unused PMT region at detector panel edges, thereby increased the field-of-view and the overall detection sensitivity and minimized the undetected breast region near the chest wall. This detector design and using regular round PMT allowed building a lower-cost, high-resolution and high-sensitivity PEM camera. PMID:20485510
NASA Astrophysics Data System (ADS)
Puszka, Agathe; Planat-Chrétien, Anne; Berger, Michel; Hervé, Lionel; Dinten, Jean-Marc
2014-02-01
We demonstrate the loss of depth sensitivity induced by the instrument response function on reflectance time-resolved diffuse optical tomography through the comparison of 3 detection systems: on one hand a photomultiplier tube (PMT) and a hybrid PMT coupled with a time-correlated single-photon counting card and on the other hand a high rate intensified camera. We experimentally evaluate the depth sensitivity achieved for each detection module with an absorbing inclusion embedded in a turbid medium. The different interfiber distances of 5, 10 and 15 mm are considered. Finally, we determine a maximal depth reached for each detection system by using 3D tomographic reconstructions based on the Mellin-Laplace transform.
Quantum efficiencies of several VUV-sensitive photomultiplier tubes
NASA Astrophysics Data System (ADS)
Dorenbos, P.; de Haas, J. T. M.; Visser, R.; van Eijk, C. W. E.; Hollander, R. W.
1993-02-01
The quantum efficiencies (QEs) of several VUV sensitive photon detectors were determined and compared with each other. We tested the following photomultiplier tubes (PMTs): five Philips XP2020Qs, one Hamamatsu R2059, and one Thorn EMI 9426. We also tested a Na-salicylate coated glass window combined with a Philips XP2020 PMT. At wavelengths smaller than 230 nm, the QEs of both the Thorn EMI and Philips PMTs appear significantly better than the QE of the Hamamatsu PMT. Furthermore, at these wavelengths, the QE of the XP2020Q PMTs was found to be much higher than advertised in the manufacturers catalogues.
Laboratory Characterization and Modeling of a Near-Infrared Enhanced Photomultiplier Tube
NASA Technical Reports Server (NTRS)
Biswas, A.; Farr, W. H.
2003-01-01
The photon-starved channel for optical communications from deep space requires the development of detector technology that can achieve photon-counting sensitivities with high bandwidth. In this article, a near-infrared enhanced photomultiplier tube (PMT) with a quantum e.ciency of 0.08 at a 1.06- m wavelength is characterized in the laboratory. A Polya distribution model is used to compute the probability distribution function of the emitted secondary photoelectrons from the PMT. The model is compared with measured pulse-height distributions with reasonable agreement. The model accounts for realistic device parameters, such as the individual dynode stage gains and a shape parameter that is representative of the spatial uniformity of response across the photocathode and dynodes. Bit-error rate (BER) measurements also are presented for 4- and 8-pulse-position modulation (PPM) modulation schemes with data rates of 20 to 30 Mb/s. A BER of 10-2 is obtained for a mean of 8 detected photons.
R&D of a pioneering system for a high resolution photodetector: The VSiPMT
NASA Astrophysics Data System (ADS)
Barbato, F. C. T.; Barbarino, G.; Campajola, L.; Di Capua, F.; Mollo, C. M.; Valentini, A.; Vivolo, D.
2017-12-01
The VSiPMT (Vacuum Silicon PhotoMultiplier Tube) is an innovative design for a hybrid photodetector. The idea, born with the purpose to use a SiPM for large detection volumes, consists in replacing the classical dynode chain with a special SiPM. In this configuration, we match the large sensitive area of a photocathode with the performances of the SiPM technology, which therefore acts like an electron detector and so like a current amplifier. The excellent photon counting capability, fast response, low power consumption and the stability are among the most attractive features of the VSiPMT.We now present the progress on the realization of a 1-in. prototype and the preliminary tests we are performing on it.
Design and performance evaluation of a high resolution IRI-microPET preclinical scanner
NASA Astrophysics Data System (ADS)
Islami rad, S. Z.; Peyvandi, R. Gholipour; lehdarboni, M. Askari; Ghafari, A. A.
2015-05-01
PET for small animal, IRI-microPET, was designed and built at the NSTRI. The scanner is made of four detectors positioned on a rotating gantry at a distance 50 mm from the center. Each detector consists of a 10×10 crystal matrix of 2×2×10 mm3 directly coupled to a PS-PMT. A position encoding circuit for specific PS-PMT has been designed, built and tested with a PD-MFS-2MS/s-8/14 data acquisition board. After implementing reconstruction algorithms (FBP, MLEM and SART) on sinograms, images quality and system performance were evaluated by energy resolution, timing resolution, spatial resolution, scatter fraction, sensitivity, RMS contrast and SNR parameters. The energy spectra were obtained for the crystals with an energy window of 300-700 keV. The energy resolution in 511 keV averaged over all modules, detectors, and crystals, was 23.5%. A timing resolution of 2.4 ns FWHM obtained by coincidence timing spectrum was measured with crystal LYSO. The radial and tangential resolutions for 18F (1.15-mm inner diameter) at the center of the field of view were 1.81 mm and 1.90 mm, respectively. At a radial offset of 5 mm, the FWHM values were 1.96 and 2.06 mm. The system scatter fraction was 7.1% for the mouse phantom. The sensitivity was measured for different energy windows, leading to a sensitivity of 1.74% at the center of FOV. Also, images quality was evaluated by RMS contrast and SNR factors, and the results show that the reconstructed images by MLEM algorithm have the best RMS contrast, and SNR. The IRI-microPET presents high image resolution, low scatter fraction values and improved SNR for animal studies.
Bubeck, Philip; Wouter Botzen, W J; Laudan, Jonas; Aerts, Jeroen C J H; Thieken, Annegret H
2017-11-17
Protection motivation theory (PMT) has become a popular theory to explain the risk-reducing behavior of residents against natural hazards. PMT captures the two main cognitive processes that individuals undergo when faced with a threat, namely, threat appraisal and coping appraisal. The latter describes the evaluation of possible response measures that may reduce or avert the perceived threat. Although the coping appraisal component of PMT was found to be a better predictor of protective intentions and behavior, little is known about the factors that influence individuals' coping appraisals of natural hazards. More insight into flood-coping appraisals of PMT, therefore, are needed to better understand the decision-making process of individuals and to develop effective risk communication strategies. This study presents the results of two surveys among more than 1,600 flood-prone households in Germany and France. Five hypotheses were tested using multivariate statistics regarding factors related to flood-coping appraisals, which were derived from the PMT framework, related literature, and the literature on social vulnerability. We found that socioeconomic characteristics alone are not sufficient to explain flood-coping appraisals. Particularly, observational learning from the social environment, such as friends and neighbors, is positively related to flood-coping appraisals. This suggests that social norms and networks play an important role in flood-preparedness decisions. Providing risk and coping information can also have a positive effect. Given the strong positive influence of the social environment on flood-coping appraisals, future research should investigate how risk communication can be enhanced by making use of the observed social norms and network effects. © 2017 Society for Risk Analysis.
Park, Rachel J; Tsao, Henry; Claus, Andrew; Cresswell, Andrew G; Hodges, Paul W
2013-02-01
Cross-sectional controlled laboratory study. To investigate the function of discrete regions of psoas major (PM) and quadratus lumborum (QL) with changes in spinal curvature and hip position. Anatomically discrete regions of PM and QL may have differential function on the lumbar spine, based on anatomical and biomechanical differences in their moment arms between fascicles within each muscle. Fine-wire electrodes were inserted with ultrasound guidance into PM fascicles arising from the transverse process (PM-t) and vertebral body (PM-v) and anterior (QL-a) and posterior (QL-p) layers of QL. Recordings were made on 9 healthy participants, who performed 7 tasks with maximal voluntary efforts and adopted 3 sitting postures that involved different spinal curvatures and hip angles. Activity of PM-t was greater during trunk extension than flexion, whereas activity of PM-v was greater during hip flexion than trunk efforts. Activity of QL-p was greater during trunk extension and lateral flexion, whereas QL-a showed greater activity during lateral flexion. During sitting tasks, PM-t was more active when sitting with a short lordosis than a flat (less extended) lumbar spine posture, whereas PM-v was similarly active in both sitting postures. Activity of PM-t was more affected by changes in position of the lumbar spine than the hip, whereas PM-v was more actively involved in the movement of the hip rather than that of the lumbar spine. Moreover, from its anatomy, PM-t has a combined potential to extend/lordose the lumbar spine and flex the hip, at least in a flexed-hip position.
Tulloch, Heather; Reida, Robert; D'Angeloa, Monika Slovinec; Plotnikoff, Ronald C; Morrina, Louise; Beatona, Louise; Papadakisa, Sophia; Pipe, Andrew
2009-03-01
The purpose of this study was to examine the utility of protection motivation theory (PMT) in the prediction of exercise intentions and behaviour in the year following hospitalisation for coronary artery disease (CAD). Patients with documented CAD (n = 787), recruited at hospital discharge, completed questionnaires measuring PMT's threat (i.e. perceived severity and vulnerability) and coping (i.e. self-efficacy, response efficacy) appraisal constructs at baseline, 2 and 6 months, and exercise behaviour at baseline, 6 and 12 months post-hospitalisation. Structural equation modelling showed that the PMT model of exercise at 6 months had a good fit with the empirical data. Self-efficacy, response efficacy, and perceived severity predicted exercise intentions, which, in turn predicted exercise behaviour. Overall, the PMT variables accounted for a moderate amount of variance in exercise intentions (23%) and behaviour (20%). In contrast, the PMT model was not reliable for predicting exercise behaviour at 12 months post-hospitalisation. The data provided support for PMT applied to short-term, but not long-term, exercise behaviour among patients with CAD. Health education should concentrate on providing positive coping messages to enhance patients' confidence regarding exercise and their belief that exercise provides health benefits, as well as realistic information about disease severity.
Large photocathode 20-inch PMT testing methods for the JUNO experiment
NASA Astrophysics Data System (ADS)
Anfimov, N.
2017-06-01
The 20 kt Liquid Scintillator (LS) JUNO detector is being constructed by the International Collaboration in China, with the primary goal of addressing the question of neutrino mass ordering (hierarchy). The main challenge for JUNO is to achieve a record energy resolution, ~ 3% at 1 MeV of energy released in the LS, which is required to perform the neutrino mass hierarchy determination. About 20 000 large 20'' PMTs with high Photon Detection Efficiency (PDE) and good photocathode uniformity will ensure an approximately 80% surface coverage of the JUNO detector. The JUNO collaboration is preparing equipment for the mass tests of all PMTs using 4 dedicated containers. Each container consists of 36 drawers. Each drawer will test a single PMT. This approach allows us to test 144 PMTs in parallel. The primary measurement in the container will be the PMT response to illumination of its photocathode by a low-intensity uniform light. Each of the 20000 PMTs will undergo the container test. Additionally, a dedicated scanning system was constructed for sampled tests of PMTs that allows us to study the variation of the PDE over the entire PMT photocathode surface. A sophisticated laboratory for PMT testing was recently built. It includes a dark room where the scanning station is housed. The core of the scanning station is a rotating frame with 7 LED sources of calibrated short light flashes that are placed along the photocathode surface covering zenith angles from the top of a PMT to its equator. It allows for the testing of individual PMTs in all relevant aspects by scanning the photocathode and identifying any potential problems. The collection efficiency of a large PMT is known to be very sensitive to the Earth Magnetic Field (EMF), therefore, understanding the necessary level of EMF suppression is crucial for the JUNO Experiment. A dark room with Helmholtz coils compensating the EMF components is available for these tests at a JUNO facility. The Hamamatsu R12860 20'' PMT is a candidate for the JUNO experiment. In this article the container design and mass-testing method, the scanning setup and scanning method are briefly described and preliminary results for performance test of this PMT are reported.
Multilayer film shields for the protection of PMT from constant magnetic field.
Dmitrenko, V V; Besson, David; Nyunt, PhyoWai; Grabchikov, S S; Grachev, V M; Muraviev-Smirnov, C C; Ulin, S E; Uteshev, Z M; Vlasik, K F
2015-01-01
Photomultiplier tubes (PMTs) are widely used in physical experiments as well as in applied devices. PMTs are sensitive to magnetic field, so creation of effective magnetic shields for their protection is very important. In this paper, the results of measurements of shielding effectiveness of multilayer film magnetic shields on PMT-85 are presented. Shields were formed by alternating layers of a material with high magnetic permeability (Ni-Fe) and high electric conductivity-Cu. The maximum number of bilayers reached 45. It is shown that in weak magnetic fields up to 0.5 mT, the output signal amplitude from PMT-85 does not change for all used multilayer shields. In strong magnetic field of 2-4 mT, the output signal amplitude decrease with 10%-40% depending from the number of layers in the shield. The Pulse distribution of PMT-85 in magnetic field 0.2-4 mT slightly changed in the range 1.1%-1.3% for the case when the number of layers do not exceed 10 and practically did not change for a shield with 45 double layers.
Recent development on the realization of a 1-inch VSiPMT prototype
NASA Astrophysics Data System (ADS)
Barbato, F. C. T.; Barbarino, G.; Campajola, L.; Di Capua, F.; Mollo, C. M.; Valentini, A.; Vivolo, D.
2017-03-01
The VSiPMT (Vacuum Silicon PhotoMultiplier Tube) is an innovative design for a revolutionary hybrid photodetector. The idea, born with the purpose to use a SiPM for large detection volumes, consists in replacing the classical dynode chain with a SiPM. In this configuration, we match the large sensitive area of a photocathode with the performances of the SiPM technology, which therefore acts like an electron detector and so like a current amplifier. The excellent photon counting capability, fast response, low power consumption and great stability are among the most attractive features of the VSiPMT. In order to realize such a device we first studied the feasibility of this detector both from theoretical and experimental point of view, by implementing a Geant4-based simulation and studying the response of a special non-windowed MPPC by Hamamatsu with an electron beam. Thanks to this result Hamamatsu realized two VSiPMT industrial prototypes with a photocathode of 3mm diameter. We present the progress on the realization of a 1-inch prototype and the preliminary tests we are performing on it.
A SPECT Scanner for Rodent Imaging Based on Small-Area Gamma Cameras
NASA Astrophysics Data System (ADS)
Lage, Eduardo; Villena, José L.; Tapias, Gustavo; Martinez, Naira P.; Soto-Montenegro, Maria L.; Abella, Mónica; Sisniega, Alejandro; Pino, Francisco; Ros, Domènec; Pavia, Javier; Desco, Manuel; Vaquero, Juan J.
2010-10-01
We developed a cost-effective SPECT scanner prototype (rSPECT) for in vivo imaging of rodents based on small-area gamma cameras. Each detector consists of a position-sensitive photomultiplier tube (PS-PMT) coupled to a 30 x 30 Nal(Tl) scintillator array and electronics attached to the PS-PMT sockets for adapting the detector signals to an in-house developed data acquisition system. The detector components are enclosed in a lead-shielded case with a receptacle to insert the collimators. System performance was assessed using 99mTc for a high-resolution parallel-hole collimator, and for a 0.75-mm pinhole collimator with a 60° aperture angle and a 42-mm collimator length. The energy resolution is about 10.7% of the photopeak energy. The overall system sensitivity is about 3 cps/μCi/detector and planar spatial resolution ranges from 2.4 mm at 1 cm source-to-collimator distance to 4.1 mm at 4.5 cm with parallel-hole collimators. With pinhole collimators planar spatial resolution ranges from 1.2 mm at 1 cm source-to-collimator distance to 2.4 mm at 4.5 cm; sensitivity at these distances ranges from 2.8 to 0.5 cps/μCi/detector. Tomographic hot-rod phantom images are presented together with images of bone, myocardium and brain of living rodents to demonstrate the feasibility of preclinical small-animal studies with the rSPECT.
A Front-End electronics board for single photo-electron timing and charge from MaPMT
NASA Astrophysics Data System (ADS)
Giordano, F.; Breton, D.; Beigbeder, C.; De Robertis, G.; Fusco, P.; Gargano, F.; Liuzzi, R.; Loparco, F.; Mazziotta, M. N.; Rizzi, V.; Tocut, V.
2013-08-01
A Front-End (FE) design based on commercial operational amplifiers has been developed to read-out signals from a Multianode PhotoMultiplier Tube (MaPMT). The overall design has been optimised for single photo-electron signal from the Hamamatsu H8500. The signal is collected by a current sensitive preamplifier and then it is fed into both a ECL fast discriminator and a shaper for analog output readout in differential mode. The analog signal and the digital gates are then registered on VME ADC and TDC modules respectively. Performances in terms of linearity, gain and timing resolution will be discussed, presenting results obtained on a test bench with differentiated step voltage inputs and also with a prototype electronic board plugged into the H8500 PMT illuminated by a picosecond laser.
Imaging photomultiplier array with integrated amplifiers and high-speed USB interfacea)
NASA Astrophysics Data System (ADS)
Blacksell, M.; Wach, J.; Anderson, D.; Howard, J.; Collis, S. M.; Blackwell, B. D.; Andruczyk, D.; James, B. W.
2008-10-01
Multianode photomultiplier tube (PMT) arrays are finding application as convenient high-speed light sensitive devices for plasma imaging. This paper describes the development of a USB-based "plug-n-play" 16-channel PMT camera with 16bits simultaneous acquisition of 16 signal channels at rates up to 2MS/s per channel. The preamplifiers and digital hardware are packaged in a compact housing which incorporates magnetic shielding, on-board generation of the high-voltage PMT bias, an optical filter mount and slits, and F-mount lens adaptor. Triggering, timing, and acquisition are handled by four field-programmable gate arrays (FPGAs) under instruction from a master FPGA controlled by a computer with a LABVIEW interface. We present technical design details and specifications and illustrate performance with high-speed images obtained on the H-1 heliac at the ANU.
Imaging photomultiplier array with integrated amplifiers and high-speed USB interface.
Blacksell, M; Wach, J; Anderson, D; Howard, J; Collis, S M; Blackwell, B D; Andruczyk, D; James, B W
2008-10-01
Multianode photomultiplier tube (PMT) arrays are finding application as convenient high-speed light sensitive devices for plasma imaging. This paper describes the development of a USB-based "plug-n-play" 16-channel PMT camera with 16 bits simultaneous acquisition of 16 signal channels at rates up to 2 MSs per channel. The preamplifiers and digital hardware are packaged in a compact housing which incorporates magnetic shielding, on-board generation of the high-voltage PMT bias, an optical filter mount and slits, and F-mount lens adaptor. Triggering, timing, and acquisition are handled by four field-programmable gate arrays (FPGAs) under instruction from a master FPGA controlled by a computer with a LABVIEW interface. We present technical design details and specifications and illustrate performance with high-speed images obtained on the H-1 heliac at the ANU.
The Vacuum Silicon Photomultiplier Tube (VSiPMT): A new version of a hybrid photon detector
NASA Astrophysics Data System (ADS)
Russo, Stefano; Barbarino, Giancarlo; de Asmundis, Riccardo; De Rosa, Gianfranca
2010-11-01
The future astroparticle experiments will study both energetic phenomena and extremely rare events from astrophysical sources. Since most of these families of experiments are carried out by using scintillation phenomena, Cherenkov or fluorescence radiation, the development of photosensitive detectors seems to be the right way to increase the experimental sensitivity. Therefore we propose an innovative design for a modern, high gain, silicon-based Vacuum Silicon Photomultiplier Tube (VSiPMT), which combines three fully established and well-understood technologies: the manufacture of hemispherical vacuum tubes with the possibility of very large active areas, the photocathode glass deposition and the novel Geiger-mode avalanche silicon photodiode (G-APD) for which a mass production is today available. This new design, based on G-APD as the electron multiplier, allows overcoming the limits of a classical PMT dynode chain.
NASA Technical Reports Server (NTRS)
Dahya, Kevin
2004-01-01
Analysis of GLAST ACD Photo-Multiplier Tube (PMT) assembly under thermal loading demonstrates that the glass tube experiences high stresses due to Coefficient of Thermal Expansion mismatch, as well as increased stress due to high stiffness and incompressibility of potting compound. Further investigation shows adverse loading effects due to the magnetic shield, a thin piece of steel wrapped around the PMT. This steel, Mu Metal, contained an overlap region that directly attributed to crack propagation in the outside surface of the tube. Sensitivities to different configurations were studied to reduce the stress and provide a more uniform loading throughout the PMT to ensure mission success. Studies indicate substituting a softer and more compressible potting compound and moving the Mu metal from the glass tube to the outside wall of the aluminum housing yields lower stress.
NASA Technical Reports Server (NTRS)
Hayashida, S.; Iikura, Y.; Shimizu, H.; Sasano, Y.; Nakane, H.; Sugimoto, N.; Matsui, I.; Takeuchi, N.
1986-01-01
The results of the observation for stratospheric aerosols which were carried out since the autumn of 1982 by using the NIES large lidar are described. Specifications of the lidar system are shown. The lidar has two wavelenghts of 1.06 and 0.53 micrometers. The 0.53 micrometer is mainly used for the stratospheric aerosols, because the PMT for 0.53 micrometers has higher sensitivity that that for 1.06 micrometers and the total efficiency is higher in the former. A switching circuit is used to control the PMT gain for avoiding signal induced noise in PMT. For the last four years, the stratospheric aerosol layer which was significantly perturbed by the El Chichon volcanic eruption was observed. The scattering ratio profiles observed from 1982 through 1983 are given.
NASA Astrophysics Data System (ADS)
Bae, Seungbin; Lee, Kisung; Seo, Changwoo; Kim, Jungmin; Joo, Sung-Kwan; Joung, Jinhun
2011-09-01
We developed a high precision position decoding method for a positron emission tomography (PET) detector that consists of a thick slab scintillator coupled with a multichannel photomultiplier tube (PMT). The DETECT2000 simulation package was used to validate light response characteristics for a 48.8 mm×48.8 mm×10 mm slab of lutetium oxyorthosilicate coupled to a 64 channel PMT. The data are then combined to produce light collection histograms. We employed a Gaussian mixture model (GMM) to parameterize the composite light response with multiple Gaussian mixtures. In the training step, light photons acquired by N PMT channels was used as an N-dimensional feature vector and were fed into a GMM training model to generate optimal parameters for M mixtures. In the positioning step, we decoded the spatial locations of incident photons by evaluating a sample feature vector with respect to the trained mixture parameters. The average spatial resolutions after positioning with four mixtures were 1.1 mm full width at half maximum (FWHM) at the corner and 1.0 mm FWHM at the center section. This indicates that the proposed algorithm achieved high performance in both spatial resolution and positioning bias, especially at the corner section of the detector.
An ultra-low background PMT for liquid xenon detectors
Akerib, D. S.; Bai, X.; Bernard, E.; ...
2012-11-15
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th / < 8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of xmore » $$\\frac{1}{24}$$ 238U / x $$\\frac{1}{9}$$ 232Th / x $$\\frac{1}{8}$$ 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of x $$\\frac{1}{25}$$ after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of \\times $$\\frac{1}{36}$$. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.« less
Cryogenic phonon-scintillation detectors with PMT readout for rare event search experiments
NASA Astrophysics Data System (ADS)
Zhang, X.; Lin, J.; Mikhailik, V. B.; Kraus, H.
2016-06-01
Cryogenic phonon-scintillation detectors (CPSD) for rare event search experiments require reliable, efficient and robust photon detectors that can resolve individual photons in a scintillation event. We report on a cryogenic detector containing a scintillating crystal, equipped with an NTD-Ge phonon sensor and a photon detector based on a low-temperature photomultiplier tube (PMT) that is powered by a Cockcroft-Walton generator. Here we present results from the characterisation of two detector modules, one with CaWO4, the other with CaMoO4 as scintillator. The energy resolutions (FWHM) at 122.1 keV for the scintillation/PMT channel are 19.9% and 29.7% respectively for CaWO4 and CaMoO4 while the energy resolutions (FWHM) for the phonon channels are 2.17 keV (1.8%) and 0.97 keV (0.79%). These characteristics compare favourably with other CPSDs currently used in cryogenic rare-event search experiments. The detection module with PMT readout benefits from the implementation of a well-understood, reliable, and commercially available component and improved time resolution, while retaining the major advantages of conventional CPSD, such as high sensitivity, resolving power and discrimination ability.
HIV/STD risk behaviors and perceptions among rural-to-urban migrants in China.
Li, Xiaoming; Fang, Xiaoyi; Lin, Danhua; Mao, Rong; Wang, Jing; Cottrell, Lesley; Harris, Carole; Stanton, Bonita
2004-12-01
Data from 2,153 sexually active rural-to-urban migrants in China were analyzed to examine the relationship between the movement of rural-to-urban migration and increased HIV/STD (sexually transmitted disease) risk and the applicability of constructs of a Western-based theory of behavioral change to the study population. Measurements included migrant mobility, sexual risk, and the seven constructs of the protection motivation theory (PMT). Data in the current study suggest that high mobility among rural-to-urban migrants was associated with increased sexual risk. The PMT constructs are applicable in identifying perceptions and attitudes associated with sexual risk behaviors in this culturally distinct population. Increased sexual risk was associated with increased perceptions of extrinsic rewards, intrinsic rewards, and response cost. Also consistent with PMT, increased sexual risk was associated with perceptions of decreased severity, vulnerability, response efficacy, and self-efficacy. After controlling for a number of key confounding factors, all seven PMT constructs were associated with sexual risk in the manner posited by the theory. The association between mobility and sexual risk underscores the importance of effective HIV/STD prevention efforts among this vulnerable population. The social cognitive theories including the PMT may form a logical base for prevention intervention programs targeting rural-to-urban migrants in China.
Costa, Fernando Oliveira; Vieira, Thaís Riberal; Cortelli, Sheila Cavalca; Cota, Luís Otávio Miranda; Costa, José Eustáquio; Aguiar, Maria Cássia Ferreira; Cortelli, José Roberto
2018-05-01
It is well established that regular compliance during periodontal maintenance therapy (PMT) maintains the stability of periodontal clinical parameters obtained after active periodontal therapy (APT). However, compliance during PMT has not yet been related to subgingival bacterial levels. Thus, this study followed individuals in PMT over 6 years and longitudinally evaluated the effects of compliance on periodontitis-associated bacterial levels and its relation to periodontal status. From a 6-year prospective cohort study with 212 individuals in PMT, 91 were determined to be eligible. From this total, 28 regular compliers (RC) were randomly selected and matched for age and sex with 28 irregular compliers (IC). Complete periodontal examination and microbiological samples were obtained 5 times: T1 (prior to APT), T2 (after APT), T3 (2 years), T4 (4 years), and T5 (6 years). Total bacteria counts and levels of Actinomyces naeslundii, Porphyromonas gingivalis, Tannerella forsythia, and Treponema denticola were evaluated through quantitative polymerase chain reaction. RC had less tooth loss and better clinical and microbiological conditions over time when compared with IC. IC had higher total bacterial counts and higher levels of T. denticola. Moreover, among IC, total bacterial counts were positively associated with plaque index and bleeding on probing, while levels of A. naeslundii, T. forsythia, and T. denticola were negatively associated with clinical attachment loss (4 to 5 mm) among RC. Compliance positively influenced subgingival microbiota and contributed to stability of periodontal clinical status. Regular visits during PMT sustained microbiological benefits provided by APT over a 6-year period. © 2018 American Academy of Periodontology.
NASA Astrophysics Data System (ADS)
Yoshida, Eiji; Kitamura, Keishi; Kimura, Yuichi; Nishikido, Fumihiko; Shibuya, Kengo; Yamaya, Taiga; Murayama, Hideo
2007-02-01
In a conventional positron emission tomography (PET) detector, detected events are projected onto a 2D position histogram by an Anger calculation for crystal identification. However, the measured histogram is affected by inter-crystal scatterings (ICS) which occur in the entire detector. Peaks which are projected for each crystal in the histogram are blurred, and this causes ICS mispositioning. A depth-of-interaction (DOI) detector has been developed for the small animal PET scanner jPET-RD. This DOI detector uses 32×32 crystals with four layers and a 256-channel multi-anode flat panel photomultiplier tube (FP-PMT) which was developed by Hamamatsu Photonics K.K. Each crystal element is 1.45×1.45×4.5 mm 3. The FP-PMT has a large detective area (49×49 mm 2) and a small anode pitch (3.04 mm). Therefore, the FP-PMT can extensively trace the behavior of incident γ rays in the crystals including ICS event. We, therefore, propose a novel method for ICS estimation using a statistical pattern recognition algorithm based on a support vector machine (SVM). In this study, we applied the SVM for discriminating photoelectric events from ICS events generated from multiple-anode outputs. The SVM was trained by uniform irradiation events generated from a detector simulator using a Monte Carlo calculation. The success rate for ICS event identification is about 78% for non-training data. The SVM can achieve a true subtraction of ICS events from measured events, and it is also useful for random correction in PET.
Rabbitt, Sarah M.; Carrubba, Erin; Lecza, Bernadette; McWhinney, Emily; Pope, Jennifer; Kazdin, Alan E.
2016-01-01
This study evaluated two Internet-based versions of Parent Management Training (PMT) and the effects of greatly reducing the contact required of a mental health professional on treatment of children referred for conduct problems. We were interested whether reduced contact with a therapist influenced treatment outcome, therapeutic alliance, parent adherence to treatment prescriptions, and parent reactions to and evaluations of the treatment procedures. Sixty children and their caregivers were assigned to receive either Full Contact PMT (with the amount of weekly contact similar to traditional PMT; approximately 50 minutes of direct therapist contact each week) or Reduced Contact PMT (with most information provided through recordings; approximately 10 minutes of therapist contact each week). Children in both groups showed significant and similar reductions in antisocial behaviors specifically, internalizing and externalizing symptoms more generally, and improvements in overall adaptive functioning. Therapeutic alliance also was similar across the two treatment groups. However, parents rated Full Contact treatment as more acceptable than the reduced version. Both treatments were similar in outcomes to in-person treatment as evaluated by a nonrandomized matched sample used as a benchmark in supplementary analyses. Overall, the findings indicate that therapist contact can be reduced while positive treatment outcomes are maintained but that interventions that reduce direct time with a therapist may be viewed less positively by clients. PMID:27453678
System design of a small OpenPET prototype with 4-layer DOI detectors.
Yoshida, Eiji; Kinouchi, Shoko; Tashima, Hideaki; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo; Yamaya, Taiga
2012-01-01
We have proposed an OpenPET geometry which consists of two axially separated detector rings. The open gap is suitable for in-beam PET. We have developed the small prototype of the OpenPET especially for a proof of concept of in-beam imaging. This paper presents an overview of the main features implemented in this prototype. We also evaluated the detector performance. This prototype was designed with 2 detector rings having 8 depth-of-interaction detectors. Each detector consisted of 784 Lu(2x)Gd(2(1-x))SiO₅:Ce (LGSO) which were arranged in a 4-layer design, coupled to a position-sensitive photomultiplier tube (PS-PMT). The size of the LGSO array was smaller than the sensitive area of the PS-PMT, so that we could obtain sufficient LGSO identification. Peripheral LGSOs near the open gap directly detect the gamma rays on the side face in the OpenPET geometry. Output signals of two detectors stacked axially were projected onto one 2-dimensional position histogram for reduction of the scale of a coincidence processor. Front-end circuits were separated from the detector head by 1.2-m coaxial cables for the protection of electronic circuits from radiation damage. The detectors had sufficient crystal identification capability. Cross talk between the combined two detectors could be ignored. The timing and energy resolutions were 3.0 ns and 14%, respectively. The coincidence window was set 20 ns, because the timing histogram showed that not only the main peak, but also two small shifted peaks were caused by the coaxial cable. However, the detector offers the promise of sufficient performance, because random coincidences are at a nearly undetectable level for in-beam PET experiments.
Qi, Liming; Xia, Yong; Qi, Wenjing; Gao, Wenyue; Wu, Fengxia; Xu, Guobao
2016-01-19
Both a wireless electrochemiluminescence (ECL) electrode microarray chip and the dramatic increase in ECL by embedding a diode in an electromagnetic receiver coil have been first reported. The newly designed device consists of a chip and a transmitter. The chip has an electromagnetic receiver coil, a mini-diode, and a gold electrode array. The mini-diode can rectify alternating current into direct current and thus enhance ECL intensities by 18 thousand times, enabling a sensitive visual detection using common cameras or smart phones as low cost detectors. The detection limit of hydrogen peroxide using a digital camera is comparable to that using photomultiplier tube (PMT)-based detectors. Coupled with a PMT-based detector, the device can detect luminol with higher sensitivity with linear ranges from 10 nM to 1 mM. Because of the advantages including high sensitivity, high throughput, low cost, high portability, and simplicity, it is promising in point of care testing, drug screening, and high throughput analysis.
The design and performance of a prototype water Cherenkov optical time-projection chamber
NASA Astrophysics Data System (ADS)
Oberla, Eric; Frisch, Henry J.
2016-04-01
A first experimental test of tracking relativistic charged particles by 'drifting' Cherenkov photons in a water-based optical time-projection chamber (OTPC) has been performed at the Fermilab Test Beam Facility. The prototype OTPC detector consists of a 77 cm long, 28 cm diameter, 40 kg cylindrical water mass instrumented with a combination of commercial 5.1 × 5.1cm2 micro-channel plate photo-multipliers (MCP-PMT) and 6.7 × 6.7cm2 mirrors. Five MCP-PMTs are installed in two columns along the OTPC cylinder in a small-angle stereo configuration. A mirror is mounted opposite each MCP-PMT on the inner surface of the detector cylinder, effectively increasing the photo-detection efficiency and providing a time-resolved image of the Cherenkov light on the opposing wall. Each MCP-PMT is coupled to an anode readout consisting of thirty 50 Ω microstrips. A 180-channel data acquisition system digitizes the MCP-PMT signals on one end of the microstrips using the PSEC4 waveform sampling-and-digitizing chip operating at a sampling rate of 10.24 Gigasamples-per-second. The single-ended microstrip readout determines the time and position of a photon arrival at the face of the MCP-PMT by recording both the direct signal and the pulse reflected from the unterminated far end of the strip. The detector was installed on the Fermilab MCenter secondary beam-line behind a steel absorber where the primary flux is multi-GeV muons. Approximately 80 Cherenkov photons are detected for a through-going muon track in a total event duration of 2 ns. By measuring the time-of-arrival and the position of individual photons at the surface of the detector to ≤ 100 ps and a few mm, respectively, we have measured a spatial resolution of 15 mm for each MCP-PMT track segment, and, from linear fits over the entire track length of 40 cm, an angular resolution on the track direction of 60 mrad.
Seifert, Lisa; Harbeck, Michaela; Thomas, Astrid; Hoke, Nadja; Zöller, Lothar; Wiechmann, Ingrid; Grupe, Gisela; Scholz, Holger C.; Riehm, Julia M.
2013-01-01
Yersinia pestis has been identified as the causative agent of the Black Death pandemic in the 14th century. However, retrospective diagnostics in human skeletons after more than 600 years are critical. We describe a strategy following a modern diagnostic algorithm and working under strict ancient DNA regime for the identification of medieval human plague victims. An initial screening and DNA quantification assay detected the Y. pestis specific pla gene of the high copy number plasmid pPCP1. Results were confirmed by conventional PCR and sequence analysis targeting both Y. pestis specific virulence plasmids pPCP1 and pMT1. All assays were meticulously validated according to human clinical diagnostics requirements (ISO 15189) regarding efficiency, sensitivity, specificity, and limit of detection (LOD). Assay specificity was 100% tested on 41 clinically relevant bacteria and 29 Y. pseudotuberculosis strains as well as for DNA of 22 Y. pestis strains and 30 previously confirmed clinical human plague samples. The optimized LOD was down to 4 gene copies. 29 individuals from three different multiple inhumations were initially assessed as possible victims of the Black Death pandemic. 7 samples (24%) were positive in the pPCP1 specific screening assay. Confirmation through second target pMT1 specific PCR was successful for 4 of the positive individuals (14%). A maximum of 700 and 560 copies per µl aDNA were quantified in two of the samples. Those were positive in all assays including all repetitions, and are candidates for future continuative investigations such as whole genome sequencing. We discuss that all precautions taken here for the work with aDNA are sufficient to prevent external sample contamination and fulfill the criteria of authenticity. With regard to retrospective diagnostics of a human pathogen and the uniqueness of ancient material we strongly recommend using a careful strategy and validated assays as presented in our study. PMID:24069445
Seifert, Lisa; Harbeck, Michaela; Thomas, Astrid; Hoke, Nadja; Zöller, Lothar; Wiechmann, Ingrid; Grupe, Gisela; Scholz, Holger C; Riehm, Julia M
2013-01-01
Yersinia pestis has been identified as the causative agent of the Black Death pandemic in the 14(th) century. However, retrospective diagnostics in human skeletons after more than 600 years are critical. We describe a strategy following a modern diagnostic algorithm and working under strict ancient DNA regime for the identification of medieval human plague victims. An initial screening and DNA quantification assay detected the Y. pestis specific pla gene of the high copy number plasmid pPCP1. Results were confirmed by conventional PCR and sequence analysis targeting both Y. pestis specific virulence plasmids pPCP1 and pMT1. All assays were meticulously validated according to human clinical diagnostics requirements (ISO 15189) regarding efficiency, sensitivity, specificity, and limit of detection (LOD). Assay specificity was 100% tested on 41 clinically relevant bacteria and 29 Y. pseudotuberculosis strains as well as for DNA of 22 Y. pestis strains and 30 previously confirmed clinical human plague samples. The optimized LOD was down to 4 gene copies. 29 individuals from three different multiple inhumations were initially assessed as possible victims of the Black Death pandemic. 7 samples (24%) were positive in the pPCP1 specific screening assay. Confirmation through second target pMT1 specific PCR was successful for 4 of the positive individuals (14%). A maximum of 700 and 560 copies per µl aDNA were quantified in two of the samples. Those were positive in all assays including all repetitions, and are candidates for future continuative investigations such as whole genome sequencing. We discuss that all precautions taken here for the work with aDNA are sufficient to prevent external sample contamination and fulfill the criteria of authenticity. With regard to retrospective diagnostics of a human pathogen and the uniqueness of ancient material we strongly recommend using a careful strategy and validated assays as presented in our study.
Gamma-ray blind beta particle probe
Weisenberger, Andrew G.
2001-01-01
An intra-operative beta particle probe is provided by placing a suitable photomultiplier tube (PMT), micro channel plate (MCP) or other electron multiplier device within a vacuum housing equipped with: 1) an appropriate beta particle permeable window; and 2) electron detection circuitry. Beta particles emitted in the immediate vicinity of the probe window will be received by the electron multiplier device and amplified to produce a detectable signal. Such a device is useful as a gamma insensitive, intra-operative, beta particle probe in surgeries where the patient has been injected with a beta emitting radiopharmaceutical. The method of use of such a device is also described, as is a position sensitive such device.
Note: Neutron bang time diagnostic system on Shenguang-III prototype
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tang, Qi; Chen, Jiabin; Liu, Zhongjie
A neutron bang time (NBT) diagnostic system has been implemented on Shenguang-III prototype. The bang time diagnostic system is based on a sensitive fusion neutron detector, which consists of a plastic scintillator and a micro-channel plate photomultiplier tube (PMT). An optical fiber bundle is used to couple the scintillator and the PMT. The bang time system is able to measure bang time above a neutron yield of 10{sup 7}. Bang times and start time of laser were related by probing x-ray pulses produced by 200 ps laser irradiating golden targets. Timing accuracy of the NBT is better than 60 ps.
Liao, Chih-Ming; Huang, Chienjin; Hsuan, Shih-Ling; Chen, Zeng-Weng; Lee, Wei-Cheng; Liu, Cheng-I; Winton, James R.; Chien, Maw-Sheng
2006-01-01
Three short fragments of recombinant subunit Pasteurella multocida toxin (rsPMT) were constructed for evaluation as candidate vaccines against progressive atrophic rhinitis (PAR) of swine. PMT-specific antibody secreting cells and evidence of cellular immunity were detected in rsPMT-immunized pigs following authentic PMT challenge or homologous antigen booster. Piglets immunized with rsPMT fragments containing either the N-terminal or the C-terminal portions of PMT developed high titers of neutralizing antibodies. Pregnant sows immunized with rsPMT had higher levels of maternal antibodies in their colostrum than did those immunized with a conventional PAR-toxoid vaccine. Offspring from rsPMT vaccinated sows had better survival after challenge with a five-fold lethal dose of authentic PMT and had better growth performance after challenge with a sublethal dose of toxin. Our findings indicate these non-toxic rsPMT proteins are attractive candidates for development of a subunit vaccine against PAR in pigs.
Metabolic characterization of Hyoscyamus niger root-specific putrescine N-methyltransferase.
Geng, Chen; Zhao, Tengfei; Yang, Chunxian; Zhang, Qiaozhuo; Bai, Feng; Zeng, Junlan; Zhang, Fangyuan; Liu, Xiaoqiang; Lan, Xiaozhong; Chen, Min; Liao, Zhihua
2018-03-02
N-methylputrescine is the precursor of nicotine and pharmaceutical tropane alkaloids such as hyoscyamine. Putrescine N-methyltransferase (PMT) catalyzes the N-methylation of putrescine to form N-methylputrescine. While the role of PMT in nicotine biosynthesis is clear, knowledge of PMT in the biosynthesis of tropane alkaloids (TAs) and the regulation of polyamines remains limited. We characterized a PMT gene from Hyoscyamus niger, designated HnPMT that was specifically expressed in roots, especially in the secondary roots and dramatically induced by methyl jasmonate (MeJA). The GUS gene was specifically expressed in Arabidopsis roots or in the vascular tissues, including pericycles and endodermis, of the H. niger hairy root cultures, when it was driven by the 5'-flanking promoter region of HnPMT. The recombinant HnPMT was purified for enzymatic assays. HnPMT converted putrescine to form N-methylputrescine, as confirmed by LC-MS. The kinetics analysis revealed that HnPMT had high affinity with putrescine but low catalytic activity, suggesting that it was a rate-limiting enzyme. When HnPMT was suppressed in the H. niger plants by using the VIGS approach, the contents of N-methylputrescine and hyoscyamine were markedly decreased, but the contents of putrescine, spermidine and a mixture of spermine and thermospermine were significantly increased; this suggested that HnPMT was involved in the biosynthesis of tropane alkaloids and played a competent role in regulating the biosynthesis of polyamines. Functional identification of HnPMT facilitated the understanding of TA biosynthesis and thus implied that the HnPMT-catalyzed step might be a target for metabolic engineering of the TA production in H. niger. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Identification of O-mannosylated Virulence Factors in Ustilago maydis
Fernández-Álvarez, Alfonso; Marín-Menguiano, Miriam; Lanver, Daniel; Jiménez-Martín, Alberto; Elías-Villalobos, Alberto; Pérez-Pulido, Antonio J.; Kahmann, Regine; Ibeas, José I.
2012-01-01
The O-mannosyltransferase Pmt4 has emerged as crucial for fungal virulence in the animal pathogens Candida albicans or Cryptococcus neoformans as well as in the phytopathogenic fungus Ustilago maydis. Pmt4 O-mannosylates specific target proteins at the Endoplasmic Reticulum. Therefore a deficient O-mannosylation of these target proteins must be responsible for the loss of pathogenicity in pmt4 mutants. Taking advantage of the characteristics described for Pmt4 substrates in Saccharomyces cerevisiae, we performed a proteome-wide bioinformatic approach to identify putative Pmt4 targets in the corn smut fungus U. maydis and validated Pmt4-mediated glycosylation of candidate proteins by electrophoretic mobility shift assays. We found that the signalling mucin Msb2, which regulates appressorium differentiation upstream of the pathogenicity-related MAP kinase cascade, is O-mannosylated by Pmt4. The epistatic relationship of pmt4 and msb2 showed that both are likely to act in the same pathway. Furthermore, constitutive activation of the MAP kinase cascade restored appressorium development in pmt4 mutants, suggesting that during the initial phase of infection the failure to O-mannosylate Msb2 is responsible for the virulence defect of pmt4 mutants. On the other hand we demonstrate that during later stages of pathogenic development Pmt4 affects virulence independently of Msb2, probably by modifying secreted effector proteins. Pit1, a protein required for fungal spreading inside the infected leaf, was also identified as a Pmt4 target. Thus, O-mannosylation of different target proteins affects various stages of pathogenic development in U. maydis. PMID:22416226
Bai, Yang; Liu, Qing; Chen, Xinguang; Gao, Yanduo; Gong, Huiyun; Tan, Xiaodong; Zhang, Min; Tuo, Jiyu; Zhang, Yuling; Xiang, Qunying; Deng, Fenghua; Liu, Guiling
2018-02-01
Despite the significance of cervical cancer screening, motivating more women to participate remains a challenge in resource-limited settings. In this study, we tested the protection motivation theory (PMT) in predicting screening intentions. Participants were women from Wufeng, a typical rural county in China. Participants (n = 3000) with no cervical cancer history were recruited from 10 randomly selected villages. As mediating variables, 6 PMT constructs (Perceived Risk, Fear Arousal, Perceived Severity, Response Efficacy, Response Cost, and Self-Efficacy) were measured using the standardized questionnaire. Structural equation modeling (SEM) method was employed to test PMT-based prediction models. Of the total sample, 57.77% believed that regular screening may reduce cervical cancer risk, and 45.26% agreed that women should be screened regularly. Our data fit the PMT model well (GFI = 0.95, AGFI = 0.93, CFI = 0.90, RMSEA = 0.06, SRMR = 0.04, Chi-square/df = 2.47). Knowledge of screening was directly and positively associated with screening intention. Age, annual income, and awareness of and prior experience with screening were significantly associated with screening intention by enhancing cervical cancer risk perception and by reducing response cost (P<0.05 for both). PMT can be used as guidance to investigate cervical cancer screening intentions among rural women in China with focus on cancer knowledge, some demographic factors, and awareness of and previous experience with screening. These findings, if verified with longitudinal data, can be used for intervention program development. Copyright © 2017 John Wiley & Sons, Ltd.
Petrik, Deborah L.; Cass, Cynthia L.; Padmakshan, Dharshana; ...
2016-02-04
Utility vectors with promoters that confer desired spatial and temporal expression patterns are useful tools for studying gene and cellular function and for industrial applications. To target the expression of DNA sequences of interest to cells forming plant secondary cell walls, which generate most of the vegetative biomass, upstream regulatory sequences of the Brachypodium distachyon lignin biosynthetic gene BdPMT and the cellulose synthase genes BdCESA7 and BdCESA8 were isolated and cloned into binary vectors designed for Agrobacterium-mediated transformation of monocots. Expression patterns were assessed using the β-glucuronidase gene GUSPlus and X-glucuronide staining. All three promoters showed strong expression levels inmore » stem tissue at the base of internodes where cell wall deposition is most active, in both vascular bundle xylem vessels and tracheids, and in interfascicular tissues, with expression less pronounced in developmentally older tissues. In leaves, BdCESA7 and BdCESA8 promoter-driven expression was strongest in leaf veins, leaf margins, and trichomes; relatively weaker and patchy expression was observed in the epidermis. BdPMT promoter-driven expression was similar to the BdCESA promoters expression patterns, including strong expression in trichomes. The intensity and extent of GUS staining varied considerably between transgenic lines, suggesting that positional effects influenced promoter activity. Introducing the BdPMT and BdCESA8 Open Reading Frames into BdPMT and BdCESA8 utility promoter binary vectors, respectively, and transforming those constructs into Brachypodium pmt and cesa8 loss-of-function mutants resulted in rescue of the corresponding mutant phenotypes. This work therefore validates the functionality of these utility promoter binary vectors for use in Brachypodium and likely other grass species. Lastly, the identification, in Bdcesa8-1 T-DNA mutant stems, of an 80% reduction in crystalline cellulose levels confirms that the BdCESA8 gene is a secondary-cell-wall-forming cellulose synthase.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petrik, Deborah L.; Cass, Cynthia L.; Padmakshan, Dharshana
Utility vectors with promoters that confer desired spatial and temporal expression patterns are useful tools for studying gene and cellular function and for industrial applications. To target the expression of DNA sequences of interest to cells forming plant secondary cell walls, which generate most of the vegetative biomass, upstream regulatory sequences of the Brachypodium distachyon lignin biosynthetic gene BdPMT and the cellulose synthase genes BdCESA7 and BdCESA8 were isolated and cloned into binary vectors designed for Agrobacterium-mediated transformation of monocots. Expression patterns were assessed using the β-glucuronidase gene GUSPlus and X-glucuronide staining. All three promoters showed strong expression levels inmore » stem tissue at the base of internodes where cell wall deposition is most active, in both vascular bundle xylem vessels and tracheids, and in interfascicular tissues, with expression less pronounced in developmentally older tissues. In leaves, BdCESA7 and BdCESA8 promoter-driven expression was strongest in leaf veins, leaf margins, and trichomes; relatively weaker and patchy expression was observed in the epidermis. BdPMT promoter-driven expression was similar to the BdCESA promoters expression patterns, including strong expression in trichomes. The intensity and extent of GUS staining varied considerably between transgenic lines, suggesting that positional effects influenced promoter activity. Introducing the BdPMT and BdCESA8 Open Reading Frames into BdPMT and BdCESA8 utility promoter binary vectors, respectively, and transforming those constructs into Brachypodium pmt and cesa8 loss-of-function mutants resulted in rescue of the corresponding mutant phenotypes. This work therefore validates the functionality of these utility promoter binary vectors for use in Brachypodium and likely other grass species. Lastly, the identification, in Bdcesa8-1 T-DNA mutant stems, of an 80% reduction in crystalline cellulose levels confirms that the BdCESA8 gene is a secondary-cell-wall-forming cellulose synthase.« less
Temperature dependence of the plastic scintillator detector for DAMPE
NASA Astrophysics Data System (ADS)
Wang, Zhao-Min; Yu, Yu-Hong; Sun, Zhi-Yu; Yue, Ke; Yan, Duo; Zhang, Yong-Jie; Zhou, Yong; Fang, Fang; Huang, Wen-Xue; Chen, Jun-Ling
2017-01-01
The Plastic Scintillator Detector (PSD) is one of the main sub-detectors in the DArk Matter Particle Explorer (DAMPE) project. It will be operated over a large temperature range from -10 to 30 °C, so the temperature effect of the whole detection system should be studied in detail. The temperature dependence of the PSD system is mainly contributed by the three parts: the plastic scintillator bar, the photomultiplier tube (PMT), and the Front End Electronics (FEE). These three parts have been studied in detail and the contribution of each part has been obtained and discussed. The temperature coefficient of the PMT is -0.320(±0.033)%/°C, and the coefficient of the plastic scintillator bar is -0.036(±0.038)%/°C. This result means that after subtracting the FEE pedestal, the variation of the signal amplitude of the PMT-scintillator system due to temperature mainly comes from the PMT, and the plastic scintillator bar is not sensitive to temperature over the operating range. Since the temperature effect cannot be ignored, the temperature dependence of the whole PSD has been also studied and a correction has been made to minimize this effect. The correction result shows that the effect of temperature on the signal amplitude of the PSD system can be suppressed. Supported by Strategic Priority Research Program on Space Science of the Chinese Academy of Sciences (XDA04040202-3) and Youth Innovation Promotion Association, CAS
Reed, Andrea; Snyder, James; Staats, Sarah; Forgatch, Marion S; Degarmo, David S; Patterson, Gerald R; Low, Sabina; Sinclair, Ryan; Schmidt, Nicole
2013-06-01
Parent management training (PMT) has beneficial effects on child and parent adjustment that last for 5 to 10 years. Short-term changes in parenting practices have been shown to mediate these effects, but the manner in which changes in specific components of parenting are sequenced and become reciprocally reinforcing (or mutually entrained) to engender and sustain the cascade of long-term beneficial effects resulting from PMT has received modest empirical attention. Long-term changes in parenting resulting from the Oregon model of PMT (PMTO) over a 2-year period were examined using data from the Oregon Divorce Study-II in which 238 recently separated mothers and their 6- to 10-year-old sons were randomly assigned to PMTO or a no treatment control (NTC) group. Multiple indicators of observed parenting practices were used to define constructs for positive parenting, monitoring and discipline at baseline, and at 6-, 12-, 18- and 30-months postbaseline. PMTO relative to NTC resulted in increased positive parenting and prevented deterioration in discipline and monitoring over the 30-month period. There were reliable sequential, transactional relationships among parenting practices; positive parenting supported better subsequent monitoring, and positive parenting and better monitoring supported subsequent effective discipline. Small improvements in parenting resulting from PMTO and small deteriorations in parenting in the NTC group may be sustained and amplified by mutually entrained relationships among parenting practices. These data about the change processes engendered by PMTO may provide information needed to enhance the power, effectiveness, and efficiency of behavioral parent training interventions.
Investigation of a Multi-Anode Microchannel Plate PMT for Time-of-Flight PET
NASA Astrophysics Data System (ADS)
Choong, Woon-Seng
2010-10-01
We report on an investigation of a mulit-anode microchannel plate PMT for time-of-flight PET detector modules. The primary advantages of an MCP lie in its excellent timing properties (fast rise time and low transit time spread), compact size, and reasonably large active area, thus making it a good candidate for TOF applications. In addition, the anode can be segmented into an array of collection electrodes with fine pitch to attain good position sensitivity. In this paper, we investigate using the Photonis Planacon MCP-PMT with a pore size of 10 μm to construct a PET detector module, specifically for time-of-flight applications. We measure the single electron response by exciting the Planacon with pulsed laser diode. We also measure the performance of the Planacon as a PET detector by coupling a 4 mm×4 mm×10 mm LSO crystal to individual pixel to study its gain uniformity, energy resolution, and timing resolution. The rise time of the Planacon is 440 ps with pulse duration of about 1 ns. A transit time spread of 120 ps FWHM is achieved. The gain is fairly uniform across the central region of the Planacon, but drops off by as much as a factor of 2.5 around the edges. The energy resolution is fairly uniform across the Planacon with an average value of 18.6 ± 0.7% FWHM. While the average timing resolution of 252 ± 7 ps FWHM is achieved in the central region of the Planacon, it degrades to 280 ± 9 ps FWHM for edge pixels and 316 ± 15 ps FWHM for corner pixels. We compare the results with measurements performed with a fast timing conventional PMT (Hamamatsu R-9800). We find that the R9800, which has significantly higher PDE, has a better timing resolution than the Planacon. Furthermore, we perform detector simulations to calculate the improvement that can be achieved with a higher PDE Planacon. The calculation shows that the Planacon can achieve significantly better timing resolution if it can attain the same PDE as the R-9800, while only a 30% improvement is needed to yield a similar timing resolution as the R-9800.
Bagley, Kenneth C; Abdelwahab, Sayed F; Tuskan, Robert G; Lewis, George K
2005-01-01
Pasteurella multocida toxin (PMT) is a potent mitogen for fibroblasts and osteoblastic cells. PMT activates phospholipase C-beta through G(q)alpha, and the activation of this pathway is responsible for its mitogenic activity. Here, we investigated the effects of PMT on human monocyte-derived dendritic cells (MDDC) in vitro and show a novel activity for PMT. In this regard, PMT activates MDDC to mature in a dose-dependent manner through the activation of phospholipase C and subsequent mobilization of calcium. This activation was accompanied by enhanced stimulation of naive alloreactive T cells and dominant inhibition of interleukin-12 production in the presence of saturating concentrations of lipopolysaccharide. Surprisingly, although PMT mimics the activating effects of cholera toxin on human MDDC and mouse bone marrow-derived dendritic cells, we found that PMT is not a mucosal adjuvant and that it suppresses the adjuvant effects of cholera toxin in mice. Together, these results indicate discordant effects for PMT in vitro compared to those in vivo.
2018-01-01
Background Plasmodium knowlesi is recognised as the main cause of human malaria in Southeast Asia. The disease is often misdiagnosed as P. falciparum or P. malariae infections by microscopy, and the disease is difficult to eliminate due to its presence in both humans and monkeys. P. knowlesi infections can rapidly cause severe disease and require prompt diagnosis and treatment. No protein biomarker exists for the rapid diagnostic test (RDT) detection of P. knowlesi infections. Plasmodium knowlesi infections can be diagnosed by PCR. Methods and principal findings Phosphoethanolamine-N-methyltransferase (PMT) is involved in malaria lipid biosynthesis and is not found in the human host. The P. falciparum, P. vivax and P. knowlesi PMT proteins were recombinantly expressed in BL21(DE3) Escherichia coli host cells, affinity purified and used to raise antibodies in chickens. Antibodies against each recombinant PMT protein all detected all three recombinant proteins and the native 29 kDa P. falciparum PMT protein on western blots and in ELISA. Antibodies against a PMT epitope (PLENNQYTDEGVKC) common to all three PMT orthologues detected all three proteins. Antibodies against unique peptides from each orthologue of PMT, PfCEVEHKYLHENKE, PvVYSIKEYNSLKDC, PkLYPTDEYNSLKDC detected only the parent protein in western blots and P. falciparum infected red blood cell lysates or blood lysates spiked with the respective proteins. Similar concentrations of PfPMT and the control, PfLDH, were detected in the same parasite lysate. The recombinant PfPMT protein was detected by a human anti-malaria antibody pool. Conclusion PMT, like the pan-specific LDH biomarker used in RDT tests, is both soluble, present at comparable concentrations in the parasite and constitutes a promising antimalarial drug target. PMT is absent from the human proteome. PMT has the potential as a biomarker for human malaria and in particular as the first P. knowlesi specific protein with diagnostic potential for the identification of a P. knowlesi infection. PMID:29505599
Krause, Robert G E; Goldring, J P Dean
2018-01-01
Plasmodium knowlesi is recognised as the main cause of human malaria in Southeast Asia. The disease is often misdiagnosed as P. falciparum or P. malariae infections by microscopy, and the disease is difficult to eliminate due to its presence in both humans and monkeys. P. knowlesi infections can rapidly cause severe disease and require prompt diagnosis and treatment. No protein biomarker exists for the rapid diagnostic test (RDT) detection of P. knowlesi infections. Plasmodium knowlesi infections can be diagnosed by PCR. Phosphoethanolamine-N-methyltransferase (PMT) is involved in malaria lipid biosynthesis and is not found in the human host. The P. falciparum, P. vivax and P. knowlesi PMT proteins were recombinantly expressed in BL21(DE3) Escherichia coli host cells, affinity purified and used to raise antibodies in chickens. Antibodies against each recombinant PMT protein all detected all three recombinant proteins and the native 29 kDa P. falciparum PMT protein on western blots and in ELISA. Antibodies against a PMT epitope (PLENNQYTDEGVKC) common to all three PMT orthologues detected all three proteins. Antibodies against unique peptides from each orthologue of PMT, PfCEVEHKYLHENKE, PvVYSIKEYNSLKDC, PkLYPTDEYNSLKDC detected only the parent protein in western blots and P. falciparum infected red blood cell lysates or blood lysates spiked with the respective proteins. Similar concentrations of PfPMT and the control, PfLDH, were detected in the same parasite lysate. The recombinant PfPMT protein was detected by a human anti-malaria antibody pool. PMT, like the pan-specific LDH biomarker used in RDT tests, is both soluble, present at comparable concentrations in the parasite and constitutes a promising antimalarial drug target. PMT is absent from the human proteome. PMT has the potential as a biomarker for human malaria and in particular as the first P. knowlesi specific protein with diagnostic potential for the identification of a P. knowlesi infection.
Performance and Results for Quartz Detector for the SuperHMS Spectrometer at Hall C Jefferson Lab
NASA Astrophysics Data System (ADS)
Griego, Benjamin F., Jr.
A quartz detector has been constructed to be part of the trigger system for the Super High Momentum Spectrometer (SHMS). The SHMS will play a pivotal role in carrying out the 12 -- GeV physics program at Hal -- C Jefferson Lab. The quartz hodoscope consists of twenty one fused silica bars. Each bar is 125 cm long, 5.5 cm wide, 2.5 cm thick, and is viewed by a UV -- sensitive PMT on each end. The quartz hodoscope's task is to provide a clean detection of charged particles, a high level of background suppression, and an accurate tracking efficiency determination. Initial test results of the quartz detectors which include light yield and position resolution will be presented.
NASA Astrophysics Data System (ADS)
Sosa, C. S.; Thompson, S. J.; Chichester, D. L.; Clarke, S. D.; Di Fulvio, A.; Pozzi, S. A.
2018-08-01
An increase in light-collection efficiency (LCE) improves the energy resolution of scintillator-based detection systems. An improvement in energy resolution can benefit detector performance, for example by lowering the measurement threshold and achieving greater accuracy in light-output calibration. This work shows that LCE can be increased by modifying the scintillator shape to reduce optical-photon reflections, thereby decreasing transmission and absorption likelihood at the reflector boundary. The energy resolution of four organic scintillators (EJ200) were compared: two cones and two right-circular cylinders, all with equal base diameter and height (50 mm). The sides of each shape had two surface conditions: one was polished and the other was ground. Each scintillator was coupled to the center of four photomultiplier tube (PMT) configurations of different diameters. The photocathode response of all PMTs was assessed as a function of position using a small cube (5 mm height) of EJ200. The worst configuration, a highly polished conical scintillator mated to a PMT of equal base diameter, produced a smeared energy spectrum. The cause of spectrum smearing is explored in detail. Results demonstrate that a ground cone had the greatest improvement in energy resolution over a ground cylinder by approximately 16.2% at 478 keVee, when using the largest diameter (127 mm) PMT. This result is attributed to the greater LCE of the cone, its ground surface, and the uniform photocathode response near center of the largest PMT. Optical-photon transport simulations in Geant4 of the cone and cylinder assuming a diffuse reflector and a uniform photocathode were compared to the best experimental configuration and agreed well. If a detector application requires excellent energy resolution above all other considerations, a ground cone on a large PMT is recommended over a cylinder.
A design of a PET detector using micro-channel plate photomultipliers with transmission-line readout
NASA Astrophysics Data System (ADS)
Kim, H.; Frisch, H.; Chen, C.-T.; Genat, J.-F.; Tang, F.; Moses, W. W.; Choong, W. S.; Kao, C.-M.
2010-10-01
A computer simulation study has been conducted to investigate the feasibility of a positron emission tomography (PET) detector design by using micro-channel plate (MCP) photomultiplier tubes (PMT) with transmission-line (TL) readout and waveform sampling. The detector unit consisted of a 24×24 array of pixelated LSO crystals, each of which was 4×4×25 mm 3 in size, and two 102×102 mm 2 MCP-PMTs coupled to both sides of the scintillator array. The crystal (and TL) pitch was 4.25 mm and reflective medium was inserted between the crystals. The transport of the optical photons inside the scintillator were simulated by using the Geant4 package. The output pulses of the MCP-PMT/TL unit were formed by applying the measured single photo-electron response of the MCP-PMT/TL unit to each individual photon that interacts with the photo-cathode of the MCP-PMT. The waveforms of the pulses at both ends of the TL strips were measured and analyzed to produce energy and timing information for the detected event. An experimental setup was developed by employing a Photonis Planacon MCP-PMT (XP85022) and a prototype TL board for measuring the single photo-electron response of the MCP-PMT/TL. The simulation was validated by comparing the predicted output pulses to measurements obtained with a single MCP-PMT/TL coupled to an LSO crystal exposed to 511 keV gamma rays. The validated simulation was then used to investigate the performance of the proposed new detector design. Our simulation result indicates an energy resolution of ˜11% at 511 keV. When using a 400-600 keV energy window, we obtain a coincidence timing resolution of ˜323 ps FWHM and a coincidence detection efficiency of ˜40% for normally incident 511 keV photons. For the positioning accuracy, it is determined by the pitch of the TLs (and crystals) in the direction normal to the TLs and measured to be ˜2.5 mm in the direction parallel to the TLs. The energy and timing obtained at the front- and back-end of the scintillator array also show differences that are correlated with the depth of interaction of the event.
Kim, H; Frisch, H; Chen, C-T; Genat, J-F; Tang, F; Moses, W W; Choong, W S; Kao, C-M
2010-01-01
A computer simulation study has been conducted to investigate the feasibility of a positron emission tomography (PET) detector design by using micro-channel plate (MCP) photomultiplier tubes (PMT) with transmission-line (TL) read-out and waveform sampling. The detector unit consisted of a 24×24 array of pixelated LSO crystals, each of which was 4×4×25 mm(3) in size, and two 102×102 mm(2) MCP-PMTs coupled to both sides of the scintillator array. The crystal (and TL) pitch was 4.25 mm and reflective medium was inserted between the crystals. The transport of the optical photons inside the scintillator were simulated by using the Geant4 package. The output pulses of the MCP-PMT/TL unit were formed by applying the measured single photo-electron response of the MCP-PMT/TL unit to each individual photon that interacts with the photo-cathode of the MCP-PMT. The waveforms of the pulses at both ends of the TL strips were measured and analyzed to produce energy and timing information for the detected event. An experimental setup was developed by employing a Photonis Planacon MCP-PMT (XP85022) and a prototype TL board for measuring the single photo-electron response of the MCP-PMT/TL. The simulation was validated by comparing the predicted output pulses to measurements obtained with a single MCP-PMT/TL coupled to an LSO crystal exposed to 511 keV gamma rays. The validated simulation was then used to investigate the performance of the proposed new detector design. Our simulation result indicates an energy resolution of ~11% at 511 keV. When using a 400-600 keV energy window, we obtain a coincidence timing resolution of ~323 ps FWHM and a coincidence detection efficiency of ~40% for normally-incident 511keV photons. For the positioning accuracy, it is determined by the pitch of the TLs (and crystals) in the direction normal to the TLs and measured to be ~2.5 mm in the direction parallel to the TLs. The energy and timing obtained at the front- and back-end of the scintillator array also show differences that are correlated with the depth of interaction of the event.
Front-end Design and Characterization for the ν-Angra Nuclear Reactor Monitoring Detector
NASA Astrophysics Data System (ADS)
Dornelas, T. I.; Araújo, F. T. H.; Cerqueira, A. S.; Costa, J. A.; Nóbrega, R. A.
2016-07-01
The Neutrinos Angra (ν-Angra) Experiment aims to construct an antineutrinos detection device capable of monitoring the Angra dos Reis nuclear reactor activity. Nuclear reactors are intense sources of antineutrinos, and the thermal power released in the fission process is directly related to the flow rate of these particles. The antineutrinos energy spectrum also provides valuable information on the nuclear source isotopic composition. The proposed detector will be equipped with photomultipliers tubes (PMT) which will be readout by a custom Amplifier-Shaper-Discriminator circuit designed to condition its output signals to the acquisition modules to be digitized and processed by an FPGA. The readout circuit should be sensitive to single photoelectron signals, process fast signals, with a full-width-half-amplitude of about 5 ns, have a narrow enough output pulse width to detect both particles coming out from the inverse beta decay (bar nue+p → n + e+), and its output amplitude should be linear to the number of photoelectrons generated inside the PMT, used for energy estimation. In this work, some of the main PMT characteristics are measured and a new readout circuit is proposed, described and characterized.
Compatibility of photomultiplier tube operation with SQUIDs for a neutron EDM experiment
NASA Astrophysics Data System (ADS)
Libersky, Matthew; nEDM Collaboration
2013-10-01
An experiment at the Spallation Neutron Source at Oak Ridge National Laboratory with the goal of reducing the experimental limit on the electric dipole moment (EDM) of the neutron will measure the precession frequencies of neutrons when a strong electric field is applied parallel and anti-parallel to a weak magnetic field. A difference in these frequencies would indicate a nonzero neutron EDM. To correct for drifts of the magnetic field in the measurement volume, polarized 3He will be used as a co-magnetometer. In one of the two methods built into the apparatus, superconducting quantum interference devices (SQUIDs) will be used to read out the 3He magnetization. Photomultiplier tubes will be used concurrently to measure scintillation light from neutron capture by 3He. However, the simultaneous noise-sensitive magnetic field measurement by the SQUIDs makes conventional PMT operation problematic due to the alternating current involved in generating the high voltages needed. Tests were carried out at Los Alamos National Laboratory to study the compatibility of simultaneous SQUID and PMT operation, using a custom battery-powered high-voltage power supply developed by Meyer and Smith (NIM A 647.1) to operate the PMT. The results of these tests will be presented.
X-ray luminescence computed tomography using a focused x-ray beam.
Zhang, Wei; Lun, Michael C; Nguyen, Alex Anh-Tu; Li, Changqing
2017-11-01
Due to the low x-ray photon utilization efficiency and low measurement sensitivity of the electron multiplying charge coupled device camera setup, the collimator-based narrow beam x-ray luminescence computed tomography (XLCT) usually requires a long measurement time. We, for the first time, report a focused x-ray beam-based XLCT imaging system with measurements by a single optical fiber bundle and a photomultiplier tube (PMT). An x-ray tube with a polycapillary lens was used to generate a focused x-ray beam whose x-ray photon density is 1200 times larger than a collimated x-ray beam. An optical fiber bundle was employed to collect and deliver the emitted photons on the phantom surface to the PMT. The total measurement time was reduced to 12.5 min. For numerical simulations of both single and six fiber bundle cases, we were able to reconstruct six targets successfully. For the phantom experiment, two targets with an edge-to-edge distance of 0.4 mm and a center-to-center distance of 0.8 mm were successfully reconstructed by the measurement setup with a single fiber bundle and a PMT. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Kwak, Hae-Soo; Chimed, Chogsom; Yoo, Sang-Hun
2016-01-01
The objective of this study was to determine the physicochemical and sensory properties of Appenzeller cheese supplemented with different concentrations (0, 1, 2, 3, and 4%, w/w) of powdered microcapsules of tomato extracts (PMT) during ripening at 14℃ for 6 mon. The particle sizes of PMT ranged from 1 to 10 m diameter with an average particle size of approximately 2 m. Butyric acid (C4) concentrations of PMT-added Appenzeller cheese were significantly higher than that of the control. Lactic acid bacteria counts in the cheese were not significantly influenced by ripening time from 0 to 6 mon or the concentrations (0-4%, w/w) of PMT. In terms of texture, the hardness of PMT-added Appenzeller cheese was significantly increased compared to the control. The gumminess and chewiness of PMT-added Appenzeller cheese were similar to those of the control. However, both cohesiveness and springiness of PMT-added Appenzeller cheese were slightly decreased. In sensory analysis, bitterness and sourness of Appenzeller cheese were not significantly changed after supplementation of PMT, but sweetness of the cheese was significantly increased after increasing the ripening time from 0 to 6 mon and increasing the concentration from 1 to 4% (w/w). Based on these results, the addition of the concentrations (1-4%, w/w) of PMT to Appenzeller cheese can be used to develop functional Appenzeller cheese. PMID:27194934
NASA Astrophysics Data System (ADS)
Bringley, Eric; Cao, Tongtong; Ilieva, Yordonka; Nadel-Turonski, Pawel; Park, Kijun; Zorn, Carl
2014-09-01
At the Thomas Jefferson National Accelerator Facility (JLab) a research and development project for a Detector of Internally-Reflected Cherenkov light for the upcoming Electron Ion Collider is underway. One goal is the development of a compact readout camera that can operate in high magnetic fields. Small-size photon sensors, such as Microchannel-Plate Photomultipliers (MCP-PMT), are key components of the readout. Here we present our work to set up and commission a dedicated test facility at JLab where MCP-PMT gain is evaluated in magnetic fields of up to 5 T, and to develop a test procedure and analysis software to determine the gain. We operate the setup in a single-photon mode, where a light-emitting diode delivers photons to the sensor's photocathode. The PMT spectrum is measured with a flash Analog-to-Digital converter (fADC). We model the spectrum as a sum of an exponential background and a convolution of Poisson and Gaussian distributions of the pedestal and multiple photoelectron peaks, respectively. We determine the PMT's gain from the position of the single-photoelectron peak obtained by fitting the fADC spectrum to the model. Our gain uncertainty is <10%. The facility is now established and will have a long-lasting value for sensor tests and beyond-nuclear-physics applications.
Dom34 Links Translation to Protein O-mannosylation
van Wijlick, Lasse; Geissen, René; Hilbig, Jessica S.; Lagadec, Quentin; Cantero, Pilar D.; Juchimiuk, Mateusz; Kluge, Sven; Wickert, Stephan; Alepuz, Paula; Ernst, Joachim F.
2016-01-01
In eukaryotes, Dom34 upregulates translation by securing levels of activatable ribosomal subunits. We found that in the yeast Saccharomyces cerevisiae and the human fungal pathogen Candida albicans, Dom34 interacts genetically with Pmt1, a major isoform of protein O-mannosyltransferase. In C. albicans, lack of Dom34 exacerbated defective phenotypes of pmt1 mutants, while they were ameliorated by Dom34 overproduction that enhanced Pmt1 protein but not PMT1 transcript levels. Translational effects of Dom34 required the 5′-UTR of the PMT1 transcript, which bound recombinant Dom34 directly at a CA/AC-rich sequence and regulated in vitro translation. Polysomal profiling revealed that Dom34 stimulates general translation moderately, but that it is especially required for translation of transcripts encoding Pmt isoforms 1, 4 and 6. Because defective protein N- or O-glycosylation upregulates transcription of PMT genes, it appears that Dom34-mediated specific translational upregulation of the PMT transcripts optimizes cellular responses to glycostress. Its translational function as an RNA binding protein acting at the 5′-UTR of specific transcripts adds another facet to the known ribosome-releasing functions of Dom34 at the 3′-UTR of transcripts. PMID:27768707
Dom34 Links Translation to Protein O-mannosylation.
van Wijlick, Lasse; Geissen, René; Hilbig, Jessica S; Lagadec, Quentin; Cantero, Pilar D; Pfeifer, Eugen; Juchimiuk, Mateusz; Kluge, Sven; Wickert, Stephan; Alepuz, Paula; Ernst, Joachim F
2016-10-01
In eukaryotes, Dom34 upregulates translation by securing levels of activatable ribosomal subunits. We found that in the yeast Saccharomyces cerevisiae and the human fungal pathogen Candida albicans, Dom34 interacts genetically with Pmt1, a major isoform of protein O-mannosyltransferase. In C. albicans, lack of Dom34 exacerbated defective phenotypes of pmt1 mutants, while they were ameliorated by Dom34 overproduction that enhanced Pmt1 protein but not PMT1 transcript levels. Translational effects of Dom34 required the 5'-UTR of the PMT1 transcript, which bound recombinant Dom34 directly at a CA/AC-rich sequence and regulated in vitro translation. Polysomal profiling revealed that Dom34 stimulates general translation moderately, but that it is especially required for translation of transcripts encoding Pmt isoforms 1, 4 and 6. Because defective protein N- or O-glycosylation upregulates transcription of PMT genes, it appears that Dom34-mediated specific translational upregulation of the PMT transcripts optimizes cellular responses to glycostress. Its translational function as an RNA binding protein acting at the 5'-UTR of specific transcripts adds another facet to the known ribosome-releasing functions of Dom34 at the 3'-UTR of transcripts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Soon Goo; Alpert, Tara D.; Jez, Joseph M.
2012-07-17
Phosphoethanolamine N-methyltransferase (PMT) is essential for phospholipid biogenesis in the malarial parasite Plasmodium falciparum. PfPMT catalyzes the triple methylation of phosphoethanolamine to produce phosphocholine, which is then used for phosphatidylcholine synthesis. Here we describe the 2.0 {angstrom} resolution X-ray crystal structure of PfPMT in complex with amodiaquine. To better characterize inhibition of PfPMT by amodiaquine, we determined the IC{sub 50} values of a series of aminoquinolines using a direct radiochemical assay. Both structural and functional analyses provide a possible approach for the development of new small molecule inhibitors of PfPMT.
Cytosolic delivery of multi-domain cargos by the N-terminus of Pasteurella multocida toxin.
Clemons, Nathan C; Bannai, Yuka; Haywood, Elizabeth E; Xu, Yiting; Buschbach, James D; Ho, Mengfei; Wilson, Brenda A
2018-05-21
The zoonotic pathogen Pasteurella multocida produces a 146-kDa modular toxin (PMT) that enters host cells and manipulates intracellular signaling through action on its Gα-protein targets. The N-terminus of PMT (PMT-N) mediates cellular uptake through receptor-mediated endocytosis, followed by delivery of the C-terminal catalytic domain from acidic endosomes into the cytosol. The putative native cargo of PMT consists of a 710-residue polypeptide of three distinct modular subdomains (C1-C2-C3), where C1 contains a membrane localization domain (MLD), C2 has as-of-yet undefined function, and C3 catalyzes deamidation of a specific active-site glutamine residue in Gα-protein targets. However, whether the three cargo subdomains are delivered intact or undergo further proteolytic processing during or after translocation from the late endosome is unclear. Here, we demonstrate that PMT-N mediates delivery of its native C-terminal cargo as a single polypeptide, corresponding to C1-C2-C3, including the MLD, with no evidence of cleavage between subdomains. We show that PMT-N also delivers into the cytosol non-native GFP cargo, further supporting that the receptor-binding and translocation functions reside within PMT-N. Our findings further show that PMT-N can deliver C1-C2 alone but that the presence of C1-C2 is important for cytosolic delivery of the catalytic C3 subdomain by PMT-N. In addition, we further refine the minimum C3 domain required for intracellular activity as comprising residues 1105-1278. These findings reinforce that PMT-N serves as the cytosolic delivery vehicle for C-terminal cargo and demonstrate that its native cargo is delivered intact as C1-C2-C3. Copyright © 2018 American Society for Microbiology.
NASA Astrophysics Data System (ADS)
Paredes, P.; Fontes, J. C.; Azevedo, E. B.; Pereira, L. S.
2017-11-01
Reference crop evapotranspiration (ETo) estimations using the FAO Penman-Monteith equation (PM-ETo) require several weather variables that are often not available. Then, ETo may be computed with procedures proposed in FAO56, either using the PM-ETo equation with temperature estimates of actual vapor pressure (e a) and solar radiation (R s), and default wind speed values (u 2), the PMT method, or using the Hargreaves-Samani equation (HS). The accuracy of estimates of daily e a, R s, and u 2 is provided in a companion paper (Paredes et al. 2017) applied to data of 20 locations distributed through eight islands of Azores, thus focusing on humid environments. Both estimation procedures using the PMT method (ETo PMT) and the HS equation (ETo HS) were assessed by statistically comparing their results with those obtained for the PM-ETo with data of the same 20 locations. Results show that both approaches provide for accurate ETo estimations, with RMSE for PMT ranging 0.48-0.73 mm day-1 and for HS varying 0.47-0.86 mm day-1. It was observed that ETo PMT is linearly related with PM-ETo, while non-linearity was observed for ETo HS in weather stations located at high elevation. Impacts of wind were not important for HS but required proper adjustments in the case of PMT. Results show that the PMT approach is more accurate than HS. Moreover, PMT allows the use of observed variables together with estimators of the missing ones, which improves the accuracy of the PMT approach. The preference for the PMT method, fully based upon the PM-ETo equation, is therefore obvious.
NASA Astrophysics Data System (ADS)
Morozov, A.; Defendi, I.; Engels, R.; Fraga, F. A. F.; Fraga, M. M. F. R.; Gongadze, A.; Guerard, B.; Jurkovic, M.; Kemmerling, G.; Manzin, G.; Margato, L. M. S.; Niko, H.; Pereira, L.; Petrillo, C.; Peyaud, A.; Piscitelli, F.; Raspino, D.; Rhodes, N. J.; Sacchetti, F.; Schooneveld, E. M.; Solovov, V.; Van Esch, P.; Zeitelhack, K.
2013-05-01
The software package ANTS (Anger-camera type Neutron detector: Toolkit for Simulations), developed for simulation of Anger-type gaseous detectors for thermal neutron imaging was extended to include a module for experimental data processing. Data recorded with a sensor array containing up to 100 photomultiplier tubes (PMT) or silicon photomultipliers (SiPM) in a custom configuration can be loaded and the positions and energies of the events can be reconstructed using the Center-of-Gravity, Maximum Likelihood or Least Squares algorithm. A particular strength of the new module is the ability to reconstruct the light response functions and relative gains of the photomultipliers from flood field illumination data using adaptive algorithms. The performance of the module is demonstrated with simulated data generated in ANTS and experimental data recorded with a 19 PMT neutron detector. The package executables are publicly available at http://coimbra.lip.pt/~andrei/
Rothe, Grit; Hachiya, Akira; Yamada, Yasuyuki; Hashimoto, Takashi; Dräger, Birgit
2003-09-01
Putrescine N-methyltransferase (PMT) is the first alkaloid-specific enzyme for nicotine and tropane alkaloid formation. The pmt gene from Nicotiana tabacum was fused to the CaMV 35S promoter and integrated into the Atropa belladonna genome. Transgenic plants and derived root cultures were analysed for gene expression and for levels of alkaloids and their precursors. Scopolamine, hyoscyamine, tropine, pseudotropine, tropinone, and calystegines were found unaltered or somewhat decreased in pmt-overexpressing lines compared to controls. When root cultures were treated with 5% sucrose, calystegine levels were elevated in control roots, but were not affected in pmt-overexpressing roots. 1 microM auxin reduced calystegine levels in control roots, while in pmt-overexpressing roots all alkaloids remained unaltered. Expression level of pmt alone is apparently not limiting for tropane alkaloid formation in A. belladonna.
He, Zhangjiang; Luo, Linli; Keyhani, Nemat O; Yu, Xiaodong; Ying, Shenghua; Zhang, Yongjun
2017-02-01
Protein O-mannosyltransferases (Pmts) belong to a highly conserved protein family responsible for the initiation of O-glycosylation of many proteins. Pmts contain one dolichyl-phosphate-mannose-protein mannosyltransferases (PMT) domain and three MIR motifs (mannosyltransferase, inositol triphosphate, and ryanodine receptor) that are essential for activity in yeast. We report that in the insect fungal pathogen, Beauveria bassiana, deletion of the C-terminal Pmt1 MIR-containing region (Pmt1∆ 311-902 ) does not alter O-mannosyltransferase activity, but does increase total cell wall protein O-mannosylation levels and results in phenotypic changes in fungal development and cell wall stability. B. bassiana mutants harboring the Pmt1 ∆ 311-902 mutation displayed a significant increase in conidiation with up-regulation of conidiation-associated genes and an increase in biomass accumulation as compared to the wild-type parent. However, decreased vegetative growth and blastospore production was noted, and Pmt1 ∆ 311-902 mutants were altered in cell wall composition and cell surface features. Insect bioassays revealed little effect on virulence for the Pmt1 ∆ 311-902 strain via cuticle infection or intrahemocoel injection assays, although differences in hyphal body differentiation in the host hemolymph and up-regulation of virulence-associated genes were noted. These data suggest novel roles for Pmt1 in negatively regulating conidiation and demonstrate that the C-terminal Pmt1 MIR-containing region is dispensable for enzymatic activity and organismal virulence.
Gain monitoring of telescope array photomultiplier cameras for the first 4 years of operation
NASA Astrophysics Data System (ADS)
Shin, B. K.; Tokuno, H.; Tsunesada, Y.; Abu-Zayyad, T.; Aida, R.; Allen, M.; Anderson, R.; Azuma, R.; Barcikowski, E.; Belz, J. W.; Bergman, D. R.; Blake, S. A.; Cady, R.; Cheon, B. G.; Chiba, J.; Chikawa, M.; Cho, E. J.; Cho, W. R.; Fujii, H.; Fujii, T.; Fukuda, T.; Fukushima, M.; Hanlon, W.; Hayashi, K.; Hayashi, Y.; Hayashida, N.; Hibino, K.; Hiyama, K.; Honda, K.; Iguchi, T.; Ikeda, D.; Ikuta, K.; Inoue, N.; Ishii, T.; Ishimori, R.; Ivanov, D.; Iwamoto, S.; Jui, C. C. H.; Kadota, K.; Kakimoto, F.; Kalashev, O.; Kanbe, T.; Kasahara, K.; Kawai, H.; Kawakami, S.; Kawana, S.; Kido, E.; Kim, H. B.; Kim, H. K.; Kim, J. H.; Kim, J. H.; Kitamoto, K.; Kitamura, S.; Kitamura, Y.; Kobayashi, K.; Kobayashi, Y.; Kondo, Y.; Kuramoto, K.; Kuzmin, V.; Kwon, Y. J.; Lim, S. I.; Machida, S.; Martens, K.; Martineau, J.; Matsuda, T.; Matsuura, T.; Matsuyama, T.; Matthews, J. N.; Myers, I.; Minamino, M.; Miyata, K.; Murano, Y.; Nagasawa, K.; Nagataki, S.; Nakamura, T.; Nam, S. W.; Nonaka, T.; Ogio, S.; Ohnishi, M.; Ohoka, H.; Oki, K.; Oku, D.; Okuda, T.; Oshima, A.; Ozawa, S.; Park, I. H.; Pshirkov, M. S.; Rodriguez, D. C.; Roh, S. Y.; Rubtsov, G.; Ryu, D.; Sagawa, H.; Sakurai, N.; Sampson, A. L.; Scott, L. M.; Shah, P. D.; Shibata, F.; Shibata, T.; Shimodaira, H.; Shin, J. I.; Shirahama, T.; Smith, J. D.; Sokolsky, P.; Sonley, T. J.; Springer, R. W.; Stokes, B. T.; Stratton, S. R.; Stroman, T.; Suzuki, S.; Takahashi, Y.; Takeda, M.; Taketa, A.; Takita, M.; Tameda, Y.; Tanaka, H.; Tanaka, K.; Tanaka, M.; Thomas, S. B.; Thomson, G. B.; Tinyakov, P.; Tkachev, I.; Tomida, T.; Troitsky, S.; Tsutsumi, K.; Tsuyuguchi, Y.; Uchihori, Y.; Udo, S.; Ukai, H.; Vasiloff, G.; Wada, Y.; Wong, T.; Wood, M.; Yamakawa, Y.; Yamane, R.; Yamaoka, H.; Yamazaki, K.; Yang, J.; Yoneda, Y.; Yoshida, S.; Yoshii, H.; Zhou, X.; Zollinger, R.; Zundel, Z.
2014-12-01
The stability of the gain of the photomultiplier (PMT) camera for the Fluorescence Detector (FD) of the Telescope Array experiment was monitored using an 241Am loaded scintillator pulsers (YAP) and a diffused xenon flasher (TXF) for a selected set of 35 PMT-readout channels. From the monitoring of YAP pulses over four years of FD operation, we found slow monotonic drifts of PMT gains at a rate of -1.7 +1.7%/year. An average of the PMT gains over the 35 channels stayed nearly constant with a rate of change measured at -0.01±0.31(stat)±0.21(sys)%/year. No systematic decrease of the PMT gain caused by the night sky background was observed. Monitoring by the TXF also tracked the PMT gain drift of the YAP at 0.88±0.14(stat)%/year.
Low Background Assay Results for LZ
NASA Astrophysics Data System (ADS)
Oliver-Mallory, Kelsey; Thomas, Keenan; Lux-Zeplin Collaboration; Berkeley Low Background Facility Team
2016-03-01
The next generation dark matter experiment LUX-ZEPLIN (LZ) requires careful control of intrinsic radioactivity in all critical detector components in order to reach its unprecedented target sensitivity to Weakly Interacting Massive Particles (WIMPs): 2 ×10-48 cm2 at 50 GeV/c2. Appropriate material selection is essential to meeting this goal, and an extensive campaign of low background screening is currently being carried out using assay devices at the Sanford Underground Research Facility and the Boulby Underground Laboratory. We will present results from this work, including measurements for the Ti cryostat, PMT bases, PMT raw materials, PTFE, and other components. This work was partially supported by the U.S. Department of Energy (DOE) under Award Number DE-AC02-05CH11231, and is based upon work supported by the National Science Foundation Graduate Research Fellowship under Grant No. 1106400.
Calibration of Sudbury Neutrino Observatory for the detection of boron-8 neutrinos
NASA Astrophysics Data System (ADS)
Ford, Richard James
1999-08-01
The Sudbury Neutrino Observatory (SNO) is a second generation water Čerenkov detector using 1000 tonnes of heavy water to study neutrino astrophysics. Using deuterium neutrino reactions, SNO will measure the flux and energy spectrum of solar electron neutrinos, and will measure the flavour-blind flux of neutrinos. A nitrogen/multi-dye laser diffuser ball has been designed and installed in SNO for calibration of the electronics, photomultiplier tubes (PMTs) and optical parameters. The laser provides pulsed radiation at 337.1 nm with a 600 psec width and pulse rate up to 50 Hz. The laser can be used directly or as a pump for one of four dye laser resonators, which provides five wavelength selections from 337-500 nm. The light is delivered to a pseudo-isotropic diffuser ball (the laserball) by a 100 μm UV-VIS fibre bundle with less than 1 nsec dispersion at 337 nm. The laserball can be deployed throughout the detector with the rope manipulator system. The laserball output is adjustable from 0.01 to 1000 photo-electrons (PE) and has a pulsewidth of 0.90 nsec at 386 nm and 1.18 nsec at 337.1 nm. A method has been developed for measuring the optical attenuation and scattering in SNO using the laserball and single photo-electron (SPE) PMT time histograms. At SPE intensity the nanosecond PMT timing can be used to separate direct and scattered light, and the extinction coefficients determined using varying path lengths from the source. A calibration function has been developed that accounts for the position and direction dependence of the response for electrons and gamma rays. The calibration function uses simplified or parameterized distributions for the Čerenkov output and detector geometry. The function is fast enough to be built in to neutrino spectrum analysis and can be used to evaluate the uncertainties in the position response. The laserball system has been tested and used to provide a PMT and electronics calibration of the detector for analysis of the airfill commissioning runs. The electronics channels were calibrated for charge pedestals and slopes, time offsets and slopes and discriminator walk (slewing). The PMT occupancies were measured and a method was developed for measuring the mean SPE gain. Finally, event reconstruction was studied for the airfill data, and a time biased reconstruction algorithm was created for cutting flashing PMT events.
Ruthig, Joelle C
2016-09-01
Protection Motivation Theory (PMT) was applied to explore the relationship between perceived risk of acute health crises and intent to exercise. Interviews of 351 community-living older adults assessed prior physical activity (PPA), all PMT components, and exercise intent. A multi-group structural equation model revealed gender differences in PMT predictors of exercise intent. PPA, age, self-efficacy, and response efficacy directly predicted men's intent. Women's PPA and age predicted PMT components of self-efficacy and response costs, which predicted intent. Findings have implications for devising interventions to enhance physical activity in later life by targeting different PMT components for older men and women. © The Author(s) 2014.
Chiron, H; Drouet, A; Claudot, A C; Eckerskorn, C; Trost, M; Heller, W; Ernst, D; Sandermann, H
2000-12-01
Formation of pinosylvin (PS) and pinosylvin 3-O-monomethyl ether (PSM), as well as the activities of stilbene synthase (STS) and S-adenosyl-1-methionine (SAM):pinosylvin O-methyltransferase (PMT), were induced strongly in needles of Scots pine seedlings upon ozone treatment, as well as in cell suspension cultures of Scots pine upon fungal elicitation. A SAM-dependent PMT protein was purified and partially characterised. A cDNA encoding PMT was isolated from an ozone-induced Scots pine cDNA library. Southern blot analysis of the genomic DNA suggested the presence of a gene family. The deduced protein sequence showed the typical highly conserved regions of O-methyltransferases (OMTs), and average identities of 20-56% to known OMTs. PMT expressed in Escherichia coli corresponded to that of purified PMT (40 kDa) from pine cell cultures. The recombinant enzyme catalysed the methylation of PS, caffeic acid, caffeoyl-CoA and quercetin. Several other substances, such as astringenin, resveratrol, 5-OH-ferulic acid, catechol and luteolin, were also methylated. Recombinant PMT thus had a relatively broad substrate specificity. Treatment of 7-year old Scots pine trees with ozone markedly increased the PMT mRNA level. Our results show that PMT represents a new SAM-dependent OMT for the methylation of stress-induced pinosylvin in Scots pine needles.
A LED-based method for monitoring NAD(P)H and FAD fluorescence in cell cultures and brain slices.
Rösner, Jörg; Liotta, Agustin; Schmitz, Dietmar; Heinemann, Uwe; Kovács, Richard
2013-01-30
Nicotinamide- and flavine-adenine-dinucleotides (NAD(P)H and FADH₂) are electron carriers involved in cellular energy metabolism and in a multitude of enzymatic processes. As reduced NAD(P)H and oxidised FAD molecules are fluorescent, changes in tissue auto-fluorescence provide valuable information on the cellular redox state and energy metabolism. Since fluorescence excitation, by mercury arc lamps (HBO) is inherently coupled to photo-bleaching and photo-toxicity, microfluorimetric monitoring of energy metabolism might benefit from the replacement of HBO lamps by light emitting diodes (LEDs). Here we describe a LED-based custom-built setup for monitoring NAD(P)H and FAD fluorescence at the level of single cells (HEK293) and of brain slices. We compared NAD(P)H bleaching characteristics with two light sources (HBO lamp and LED) as well as sensitivity and signal to noise ratio of three different detector types (multi-pixel photon counter (MPPC), photomultiplier tube (PMT) and photodiode). LED excitation resulted in reduced photo-bleaching at the same fluorescence output in comparison to excitation with the HBO lamp. Transiently increasing LED power resulted in reversible bleaching of NAD(P)H fluorescence. Recovery kinetics were dependent on metabolic substrates indicating coupling of NAD(P)H fluorescence to metabolism. Electrical stimulation of brain slices induced biphasic redox changes, as indicated by NAD(P)H/FAD fluorescence transients. Increasing the gain of PMT and decreasing the LED power resulted in similar sensitivity as obtained with the MPPC and the photodiode, without worsening the signal to noise ratio. In conclusion, replacement of HBO lamp with LED might improve conventional PMT based microfluorimetry of tissue auto-fluorescence. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Gawadiak, Yuri; Wong, Alan; Maluf, David; Bell, David; Gurram, Mohana; Tran, Khai Peter; Hsu, Jennifer; Yagi, Kenji; Patel, Hemil
2007-01-01
The Program Management Tool (PMT) is a comprehensive, Web-enabled business intelligence software tool for assisting program and project managers within NASA enterprises in gathering, comprehending, and disseminating information on the progress of their programs and projects. The PMT provides planning and management support for implementing NASA programmatic and project management processes and requirements. It provides an online environment for program and line management to develop, communicate, and manage their programs, projects, and tasks in a comprehensive tool suite. The information managed by use of the PMT can include monthly reports as well as data on goals, deliverables, milestones, business processes, personnel, task plans, monthly reports, and budgetary allocations. The PMT provides an intuitive and enhanced Web interface to automate the tedious process of gathering and sharing monthly progress reports, task plans, financial data, and other information on project resources based on technical, schedule, budget, and management criteria and merits. The PMT is consistent with the latest Web standards and software practices, including the use of Extensible Markup Language (XML) for exchanging data and the WebDAV (Web Distributed Authoring and Versioning) protocol for collaborative management of documents. The PMT provides graphical displays of resource allocations in the form of bar and pie charts using Microsoft Excel Visual Basic for Application (VBA) libraries. The PMT has an extensible architecture that enables integration of PMT with other strategic-information software systems, including, for example, the Erasmus reporting system, now part of the NASA Integrated Enterprise Management Program (IEMP) tool suite, at NASA Marshall Space Flight Center (MSFC). The PMT data architecture provides automated and extensive software interfaces and reports to various strategic information systems to eliminate duplicative human entries and minimize data integrity issues among various NASA systems that impact schedules and planning.
Ghahremani, Leila; Harami, Zahra Khiyali; Kaveh, Mohammad Hossein; Keshavarzi, Sareh
2016-01-01
Cervical cancer is known as one of the most prevalent types of cancers and a major public health problem in developing countries which can be detected by Pap test, prevented, and treated. Despite the effective role of Pap test in decreasing the incidence and mortality due to cervical cancer, it is still one the most common causes of cancer-related deaths among women, especially in developing countries. Thus, this study aimed to examine the effect of educational interventions implemented by health volunteers based on protection motivation theory (PMT) on promoting Pap test use among women. This quasi-experimental study was conducted on 60 health volunteers and 420 women. The study participants were divided into an intervention and a control group. Data were collected using a valid self-reported questionnaire including demographic variables and PMT constructs which was completed by both groups before and 2 months after the intervention. Then, the data were entered into the SPSS statistical software, version 19 and were analyzed using Chi-square test, independent T-test, and descriptive statistical methods. P<0.05 was considered as statistically significant. The findings of this study showed that the mean scores of PMT constructs (i.e. perceived vulnerability, perceived severity, fear, response-costs, self-efficacy, and intention) increased in the intervention group after the intervention (P<0.001). However, no significant difference was found between the two groups regarding response efficacy after the intervention (P=0.06). The rate of Pap test use also increased by about 62.9% among the study women. This study showed a significant positive relationship between PMT-based training and Pap test use. The results also revealed the successful contribution of health volunteers to training cervical cancer screening. Thus, training interventions based on PMT are suggested to be designed and implemented and health volunteers are recommended to be employed for educational purposes and promoting the community's, especially women's, health.
Petrik, Deborah L; Karlen, Steven D; Cass, Cynthia L; Padmakshan, Dharshana; Lu, Fachuang; Liu, Sarah; Le Bris, Philippe; Antelme, Sébastien; Santoro, Nicholas; Wilkerson, Curtis G; Sibout, Richard; Lapierre, Catherine; Ralph, John; Sedbrook, John C
2014-01-01
Grass lignins contain substantial amounts of p-coumarate (pCA) that acylate the side-chains of the phenylpropanoid polymer backbone. An acyltransferase, named p-coumaroyl-CoA:monolignol transferase (OsPMT), that could acylate monolignols with pCA in vitro was recently identified from rice. In planta, such monolignol-pCA conjugates become incorporated into lignin via oxidative radical coupling, thereby generating the observed pCA appendages; however p-coumarates also acylate arabinoxylans in grasses. To test the authenticity of PMT as a lignin biosynthetic pathway enzyme, we examined Brachypodium distachyon plants with altered BdPMT gene function. Using newly developed cell wall analytical methods, we determined that the transferase was involved specifically in monolignol acylation. A sodium azide-generated Bdpmt-1 missense mutant had no (<0.5%) residual pCA on lignin, and BdPMT RNAi plants had levels as low as 10% of wild-type, whereas the amounts of pCA acylating arabinosyl units on arabinoxylans in these PMT mutant plants remained unchanged. pCA acylation of lignin from BdPMT-overexpressing plants was found to be more than three-fold higher than that of wild-type, but again the level on arabinosyl units remained unchanged. Taken together, these data are consistent with a defined role for grass PMT genes in encoding BAHD (BEAT, AHCT, HCBT, and DAT) acyltransferases that specifically acylate monolignols with pCA and produce monolignol p-coumarate conjugates that are used for lignification in planta. PMID:24372757
The O-methyltransferase PMT2 mediates methylation of pinosylvin in Scots pine.
Paasela, Tanja; Lim, Kean-Jin; Pietiäinen, Milla; Teeri, Teemu H
2017-06-01
Heartwood extractives are important determinants of the natural durability of pine heartwood. The most important phenolic compounds affecting durability are the stilbenes pinosylvin and its monomethylether, which in addition have important functions as phytoalexins in active defense. A substantial portion of the synthesized pinosylvin is 3-methoxylated but the O-methyltransferase responsible for this modification has not been correctly identified. We studied the expression of the stilbene pathway during heartwood development as well as in response to wounding of xylem and UV-C treatment of needles. We isolated and enzymatically characterized a novel O-methyltransferase, PMT2. The methylated product was verified as pinosylvin monomethylether using ultra performance liquid chromatography-tandem mass spectrometry and high performance liquid chromatography analyses. The PMT2 enzyme was highly specific for stilbenes as substrate, in contrast to caffeoyl-CoA O-methyltransferase (CCoAOMT) and PMT1 that were multifunctional. Expression profile and multifunctional activity of CCoAOMT suggest that it might have additional roles outside lignin biosynthesis. PMT1 is not involved in the stilbene pathway and its biological function remains an open question. We isolated a new specific O-methyltransferase responsible for 3-methoxylation of pinosylvin. Expression of PMT2 closely follows stilbene biosynthesis during developmental and stress induction. We propose that PMT2 is responsible for pinosylvin methylation in Scots pine (Pinus sylvestris), instead of the previously characterized methyltransferase, PMT1. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.
Implementing Parent Management Training in the Context of Poverty.
ERIC Educational Resources Information Center
Eamon, Mary Keegan; Venkataraman, Meenakshi
2003-01-01
Parent management training (PMT) is a well-investigated, effective, and preferred treatment for children's externalizing behaviors and related disorders. This article explores why, unfortunately, PMT is not as effective for children living in poor families, who disproportionately exhibit the behaviors that PMT is designed to correct. (Contains 40…
Charge reconstruction in large-area photomultipliers
NASA Astrophysics Data System (ADS)
Grassi, M.; Montuschi, M.; Baldoncini, M.; Mantovani, F.; Ricci, B.; Andronico, G.; Antonelli, V.; Bellato, M.; Bernieri, E.; Brigatti, A.; Brugnera, R.; Budano, A.; Buscemi, M.; Bussino, S.; Caruso, R.; Chiesa, D.; Corti, D.; Dal Corso, F.; Ding, X. F.; Dusini, S.; Fabbri, A.; Fiorentini, G.; Ford, R.; Formozov, A.; Galet, G.; Garfagnini, A.; Giammarchi, M.; Giaz, A.; Insolia, A.; Isocrate, R.; Lippi, I.; Longhitano, F.; Lo Presti, D.; Lombardi, P.; Marini, F.; Mari, S. M.; Martellini, C.; Meroni, E.; Mezzetto, M.; Miramonti, L.; Monforte, S.; Nastasi, M.; Ortica, F.; Paoloni, A.; Parmeggiano, S.; Pedretti, D.; Pelliccia, N.; Pompilio, R.; Previtali, E.; Ranucci, G.; Re, A. C.; Romani, A.; Saggese, P.; Salamanna, G.; Sawy, F. H.; Settanta, G.; Sisti, M.; Sirignano, C.; Spinetti, M.; Stanco, L.; Strati, V.; Verde, G.; Votano, L.
2018-02-01
Large-area PhotoMultiplier Tubes (PMT) allow to efficiently instrument Liquid Scintillator (LS) neutrino detectors, where large target masses are pivotal to compensate for neutrinos' extremely elusive nature. Depending on the detector light yield, several scintillation photons stemming from the same neutrino interaction are likely to hit a single PMT in a few tens/hundreds of nanoseconds, resulting in several photoelectrons (PEs) to pile-up at the PMT anode. In such scenario, the signal generated by each PE is entangled to the others, and an accurate PMT charge reconstruction becomes challenging. This manuscript describes an experimental method able to address the PMT charge reconstruction in the case of large PE pile-up, providing an unbiased charge estimator at the permille level up to 15 detected PEs. The method is based on a signal filtering technique (Wiener filter) which suppresses the noise due to both PMT and readout electronics, and on a Fourier-based deconvolution able to minimize the influence of signal distortions—such as an overshoot. The analysis of simulated PMT waveforms shows that the slope of a linear regression modeling the relation between reconstructed and true charge values improves from 0.769 ± 0.001 (without deconvolution) to 0.989 ± 0.001 (with deconvolution), where unitary slope implies perfect reconstruction. A C++ implementation of the charge reconstruction algorithm is available online at [1].
Maternal-fetal disease information as a source of exercise motivation during pregnancy.
Gaston, Anca; Prapavessis, Harry
2009-11-01
A Protection Motivation Theory (PMT) framework was used to examine whether information about the role of exercise in preventing maternal-fetal disease served as a meaningful source of exercise motivation. Pregnant women (n = 208) were randomly assigned into one of three conditions: PMT, attention control, and noncontact control. Women in the PMT group read a brochure about the benefits of exercise during pregnancy incorporating the major components of PMT; perceived vulnerability (PV), perceived severity (PS), response efficacy (RE), and self-efficacy (SE). Participants in the attention-control condition read a brochure about diet. Following treatment, all participants completed measures of their beliefs toward maternal-fetal disease and exercise, goal intention (GI), and implementation intention (IMI). One week later, a measure of self-reported exercise behavior was collected. Main outcome measures were PMT variables (PV, PS, RE, and SE), GI, IMI, and follow-up physical activity. Participants assigned to the PMT-present group reported significantly higher PS, RE, SE, GI, and increased exercise behavior. PS, RE, and SE predicted GI, GI predicted IMI, and IMI predicted exercise behavior. Information grounded in PMT is effective in influencing pregnant women's beliefs and intentions as well as changing their initial behavior. PsycINFO Database Record (c) 2009 APA, all rights reserved.
2011-01-01
Background Tropane alkaloids (TA) including anisodamine, anisodine, hyoscyamine and scopolamine are a group of important anticholinergic drugs with rapidly increasing market demand, so it is significant to improve TA production by biotechnological approaches. Putrescine N-methyltransferase (PMT) was considered as the first rate-limiting upstream enzyme while tropinone reductase I (TRI) was an important branch-controlling enzyme involved in TA biosynthesis. However, there is no report on simultaneous introduction of PMT and TRI genes into any TA-producing plant including Anisodus acutangulus (A. acutangulus), which is a Solanaceous perennial plant that is endemic to China and is an attractive resource plant for production of TA. Results In this study, 21 AaPMT and AaTRI double gene transformed lines (PT lines), 9 AaPMT single gene transformed lines (P lines) and 5 AaTRI single gene transformed lines (T lines) were generated. RT-PCR and real-time fluorescence quantitative analysis results revealed that total AaPMT (AaPMT T) and total AaTRI (AaTRI T) gene transcripts in transgenic PT, P and T lines showed higher expression levels than native AaPMT (AaPMT E) and AaTRI (AaTRI E) gene transcripts. As compared to the control and single gene transformed lines (P or T lines), PT transgenic hairy root lines produced significantly higher levels of TA. The highest yield of TA was detected as 8.104 mg/g dw in line PT18, which was 8.66, 4.04, and 3.11-times higher than those of the control (0.935 mg/g dw), P3 (highest in P lines, 2.004 mg/g dw) and T12 (highest in T lines, 2.604 mg/g dw), respectively. All the tested samples were found to possess strong radical scavenging capacity, which were similar to control. Conclusion In the present study, the co-expression of AaPMT and AaTRI genes in A. acutangulus hairy roots significantly improved the yields of TA and showed higher antioxidant activity than control because of higher total TA content, which is the first report on simultaneous introduction of PMT and TRI genes into TA-producing plant by biotechnological approaches. PMID:21526999
Photon-counting-based diffraction phase microscopy combined with single-pixel imaging
NASA Astrophysics Data System (ADS)
Shibuya, Kyuki; Araki, Hiroyuki; Iwata, Tetsuo
2018-04-01
We propose a photon-counting (PC)-based quantitative-phase imaging (QPI) method for use in diffraction phase microscopy (DPM) that is combined with a single-pixel imaging (SPI) scheme (PC-SPI-DPM). This combination of DPM with the SPI scheme overcomes a low optical throughput problem that has occasionally prevented us from obtaining quantitative-phase images in DPM through use of a high-sensitivity single-channel photodetector such as a photomultiplier tube (PMT). The introduction of a PMT allowed us to perform PC with ease and thus solved a dynamic range problem that was inherent to SPI. As a proof-of-principle experiment, we performed a comparison study of analogue-based SPI-DPM and PC-SPI-DPM for a 125-nm-thick indium tin oxide (ITO) layer coated on a silica glass substrate. We discuss the basic performance of the method and potential future modifications of the proposed system.
Occulting Light Concentrators in Liquid Scintillator Neutrino Detectors
NASA Astrophysics Data System (ADS)
Buizza Avanzini, Margherita; Cabrera, Anatael; Dusini, Stefano; Grassi, Marco; He, Miao; Wu, Wenjie
2017-09-01
The experimental efforts characterizing the era of precision neutrino physics revolve around collecting high-statistics neutrino samples and attaining an excellent energy and position resolution. Next generation liquid-based neutrino detectors, such as JUNO, HyperKamiokande, etc, share the use of a large target mass, and the need of pushing light collection to the edge for maximal calorimetric information. Achieving high light collection implies considerable costs, especially when considering detector masses of several kt. A traditional strategy to maximize the effective photo-coverage with the minimum number of PMTs relies on Light Concentrators (LC), such as Winston Cones. In this paper, the authors introduce a novel concept called Occulting Light Concentrators (OLC), whereby a traditional LC gets tailored to a conventional PMT, by taking into account its single-photoelectron collection efficiency profile and thus occulting the worst performing portion of the photocathode. Thus, the OLC shape optimization takes into account not only the optical interface of the PMT, but also the maximization of the PMT detection performances. The light collection uniformity across the detector is another advantage of the OLC system. By considering the case of JUNO, we will show OLC capabilities in terms of light collection and energy resolution.
Synthetic Pulse Dilation - PMT Model for high bandwidth gamma measurements
NASA Astrophysics Data System (ADS)
Geppert-Kleinrath, H.; Herrmann, H. W.; Kim, Y. H.; Zylstra, A. B.; Meaney, K. D.; Lopez, F. E.; Khater, H.; Horsfield, C. J.; Gales, S.; Leatherland, A.; Hilsabeck, T.; Kilkenny, J. D.; Hares, J. D.; Dymoke-Bradshaw, T.; Milnes, J.
2017-10-01
The Cherenkov mechanism used in Gas Cherenkov Detectors (GCD) is exceptionally fast. However, the temporal resolution of GCDs, such as the Gamma Reaction History diagnostic (GRH), is limited by the current state-of-the-art photomultiplier tube (PMT) to 100 ps. The new pulse dilation - PMT (PD-PMT) for NIF allows for a temporal resolution comparable to that of the gas cell, or of 10ps. Enhanced resolution will contribute to the quest for ignition in a crucial way through precision measurement of reaction history and areal density (ρ R) history, leading to better constrained models. Features such as onset of alpha heating, shock reverberations and burn truncation due to dynamically evolving failure modes will become visible for the first time. PD-PMT will be deployed on GCD-3 at NIF in 2018. Our synthetic PD-PMT model evaluates the capabilities of these future measurements, as well as minimum yield requirements for measurements performed in a well at 3.9 m from target chamber center (TCC), and within a diagnostic inserter at 0.2m from TCC.
Performance evaluation for 120 four-layer DOI block detectors of the jPET-D4.
Inadama, Naoko; Murayama, Hideo; Ono, Yusuke; Tsuda, Tomoaki; Hamamoto, Manabu; Yamaya, Taiga; Yoshida, Eiji; Shibuya, Kengo; Nishikido, Fumihiko; Takahashi, Kei; Kawai, Hideyuki
2008-01-01
The jPET-D4 is a brain positron emission tomography (PET) scanner that we have developed to meet user demands for high sensitivity and high spatial resolution. For this scanner, we developed a four-layer depth-of-interaction (DOI) detector. The four-layer DOI detector is a key component for the jPET-D4, its performance has great influence on the overall system performance. Previously, we reported the original technique for encoding four-layer DOI. Here, we introduce the final design of the jPET-D4 detector and present the results of an investigation on uniformity in performance of the detector. The performance evaluation was done over the 120 DOI crystal blocks for the detectors, which are to be assembled into the jPET-D4 scanner. We also introduce the crystal assembly method, which is simple enough, even though each DOI crystal block is composed of 1,024 crystal elements. The jPET-D4 detector consists of four layers of 16 x 16 Gd(2)SiO(5) (GSO) crystals and a 256-channel flat-panel position-sensitive photomultiplier tube (256ch FP-PMT). To identify scintillated crystals in the four-layer DOI detector, we use pulse shape discrimination and position discrimination on the two-dimensional (2D) position histogram. For pulse shape discrimination, two kinds of GSO crystals that show different scintillation decay time constants are used in the upper two and lower two layers, respectively. Proper reflector arrangement in the crystal block then allows the scintillated crystals to be identified in these two-layer groupings with two 2D position histograms. We produced the 120 DOI crystal blocks for the jPET-D4 system, and measured their characteristics such as the accuracy of pulse shape discrimination, energy resolution, and the pulse height of the full energy peak. The results show a satisfactory and uniform performance of the four-layer DOI crystal blocks; for example, misidentification rate in each GSO layer is <5% based on pulse shape discrimination, the averaged energy resolutions for the central four crystals of the first (farthest from the FP-PMT), second, third, and 4th layers are 15.7 +/- 1.0, 15.8 +/- 0.6, 17.7 +/- 1.2, and 17.3 +/- 1.4%, respectively, and variation in pulse height of the full energy peak among the four layers is <5% on average.
Fernández-Álvarez, Alfonso; Elías-Villalobos, Alberto; Ibeas, José I.
2009-01-01
In Saccharomyces cerevisiae, the PMT, KRE2/MNT1, and MNN1 mannosyltransferase protein families catalyze the steps of the O-mannosylation pathway, sequentially adding mannoses to target proteins. We have identified members of all three families and analyzed their roles in pathogenesis of the maize smut fungus Ustilago maydis. Furthermore, we have shown that PMT4, one of the three PMT family members in U. maydis, is essential for tumor formation in Zea mays. Significantly, PMT4 seems to be required only for pathogenesis and is dispensable for other aspects of the U. maydis life cycle. We subsequently show that the deletion of pmt4 results in a strong reduction in the frequency of appressorium formation, with the few appressoria that do form lacking the capacity to penetrate the plant cuticle. Our findings suggest that the O-mannosylation pathway plays a key role in the posttranslational modification of proteins involved in the pathogenic development of U. maydis. The fact that PMT homologs are not found in plants may open new avenues for the development of fungal control strategies. Moreover, the discovery of a highly specific requirement for a single O-mannosyltransferase should aid in the identification of the proteins directly involved in fungal plant penetration, thus leading to a better understanding of plant–fungi interactions. PMID:19880800
A Gain-Programmable Transit-Time-Stable and Temperature-Stable PMT Voltage Divider
NASA Astrophysics Data System (ADS)
Liu, Yaqiang; Li, Hongdi; Wang, Yu; Xing, Tao; Xie, Shuping; Uribe, J.; Baghaei, H.; Ramirez, R.; Kim, Soonseok; Wong, Wai-Hoi
2004-10-01
A gain-programmable, transit-time-stable, temperature-stable photomultiplier (PMT) voltage divider design is described in this paper. The signal-to-noise ratio can be increased by changing a PMT gain directly instead of adjusting the gain of the preamplifier. PMT gain can be changed only by adjusting the voltages for the dynodes instead of changing the total high voltage between the anode and the photocathode, which can cause a significant signal transit-time variation that cannot be accepted by an application with a critical timing requirement, such as positron emission tomography (PET) or time-of-flight (TOF) detection/PET. The dynode voltage can be controlled by a digital analog converter isolated with a linear optocoupler. The optocoupler consists of an infrared light emission diode (LED) optically coupled with two phototransistors, and one is used in a servo feedback circuit to control the LED drive current for compensating temperature characteristics. The results showed that a six times gain range could be achieved; the gain drift was <0.5% over a 20/spl deg/C temperature range; 250 ps transit-time variation was measured over the entire gain range. A compact print circuit board (PCB) for the voltage divider integrated with a fixed-gain preamplifier has been designed and constructed. It can save about $30 per PMT channel compared with a commercial PMT voltage divider along with a variable gain amplifier. The preamplifier can be totally disabled, therefore in a system with a large amount of PMTs, only one channel can be enabled for calibrating the PMT gain. This new PMT voltage divider design is being applied to our animal PET camera and TOF/PET research.
Localization of the Intracellular Activity Domain of Pasteurella multocida Toxin to the N Terminus
Wilson, Brenda A.; Ponferrada, Virgilio G.; Vallance, Jefferson E.; Ho, Mengfei
1999-01-01
We have shown that Pasteurella multocida toxin (PMT) directly causes transient activation of Gqα protein that is coupled to phosphatidylinositol-specific phospholipase Cβ1 in Xenopus oocytes (B. A. Wilson, X. Zhu, M. Ho, and L. Lu, J. Biol. Chem. 272:1268–1275, 1997). We found that antibodies directed against an N-terminal peptide of PMT inhibited the toxin-induced response in Xenopus oocytes, but antibodies against a C-terminal peptide did not. To test whether the intracellular activity domain of PMT is localized to the N terminus, we conducted a deletion mutational analysis of the PMT protein, using the Xenopus oocyte system as a means of screening for toxin activity. Using PCR and conventional cloning techniques, we cloned from a toxinogenic strain of P. multocida the entire toxA gene, encoding the 1,285-amino-acid PMT protein, and expressed the recombinant toxin as a His-tagged fusion protein in Escherichia coli. We subsequently generated a series of N-terminal and C-terminal deletion mutants and expressed the His-tagged PMT fragments in E. coli. These proteins were screened for cytotoxic activity on cultured Vero cells and for intracellular activity in the Xenopus oocyte system. Only the full-length protein without the His tag exhibited activity on Vero cells. The full-length PMT and N-terminal fragments containing the first 500 residues elicited responses in oocytes, but the C-terminal 780 amino acid fragment did not. Our results confirm that the intracellular activity domain of PMT is localized to the N-terminal 500 amino acids of the protein and that the C terminus is required for entry into cells. PMID:9864199
DOE Office of Scientific and Technical Information (OSTI.GOV)
Divani, Nazila, E-mail: n-divani@birjand.ac.ir; Firoozabadi, Mohammad M.; Bayat, Esmail
Scintillators are almost used in any nuclear laboratory. These detectors combine of scintillation materials, PMT and a voltage divider. Voltage dividers are different in resistive ladder design. But the effect of decoupling capacitors and damping resistors haven’t discussed yet. In this paper at first a good equilibrium circuit designed for PMT, and it was used for investigating about capacitors and resistors in much manner. Results show that decoupling capacitors have great effect on PMT output pulses. In this research, it was tried to investigate the effect of Capacitor’s value and places on PMT voltage divider in Neutron-Gamma discrimination capability. Therefore,more » the voltage divider circuit for R329-02 Hamamatsu PMT was made and Zero Cross method used for neutron-gamma discrimination. The neutron source was a 20Ci Am-Be. Anode and Dynode pulses and discrimination spectrum were saved. The results showed that the pulse height and discrimination quality change with the value and setting of capacitors.« less
Light concentrator of the wide field of view Cherenkov telescope
NASA Astrophysics Data System (ADS)
Yang, Rui; Sheng, Xi Yi; Liao, Bo Lin
2016-10-01
The Wide Field of View Cherenkov Telescope (WFCT) is mainly constituted by optical reflector and focal-plane photomultiplier (PMT) array camera. In order to avoid loss of Cherenkov signal resulting from the dead area between circular PMT tubes and invalid fringe of each PMT, the light concentrator used as front window of PMT is considered to improve detective efficiency. Basing on the edge-ray principle and features of WFCT, several light concentrators are designed and simulated with ZEMAX. The result shows that the hollow hexahedral compound parabolic concentrator (hex-CPC) has good performance in collecting light. Moreover, the samples of the hollow hexahedral CPC have been manufactured and tested.
Multianode Photomultiplier Tube Alignment for the MINERvA Experiment at Fermilab
NASA Astrophysics Data System (ADS)
Bruno, Jorge
2006-10-01
The MINERvA experiment (Main INjector ExpeRiment vA) at FNAL will study the neutrino-nucleon and neutrino-nucleus interaction. The light collection from the detector will be done via optic fibers using Hamamatsu H8804 64-channel photomultiplier tubes (PMT). Each PMT channel needs to be precisely aligned with the corresponding optic fiber. The MINERvA PMT optical boxes contain precision machined optic ``cookies'' which capture the 8x8 array of optic fibers. Each PMT-cookie pair needs to be aligned as precisely as possible. This contribution will describe the alignment setup and procedure implemented at James Madison University.
Garg, Aprajita; Lukk, Tiit; Kumar, Vidya; ...
2015-03-12
Phosphoethanolamine methyltransferases (PMTs) catalyze the three-step methylation of phosphoethanolamine to form phosphocholine, a critical step in the synthesis of phosphatidylcholine in a select number of eukaryotes including human malaria parasites, nematodes and plants. Genetic studies in the malaria parasite Plasmodium falciparum have shown that the methyltransferase PfPMT plays a critical function in parasite development and differentiation. The presence of PMT orthologs in other malaria parasites that infect humans and their absence in mammals make them ideal targets for the development of selective antimalarials with broad specificity against different Plasmodium species. Here we describe the X-ray structures and biochemical properties ofmore » PMT orthologs from Plasmodium vivax and Plasmodium knowlesi and show that both enzymes are inhibited by amodiaquine and NSC158011, two drugs with potent antimalarial activity. Metabolic studies in a yeast mutant that relies on PkPMT or PvPMT for survival demonstrated that these compounds inhibit phosphatidylcholine biosynthesis from ethanolamine. Our structural and functional data provide insights into the mechanism of catalysis and inhibition of PMT enzymes and set the stage for a better design of more specific and selective antimalarial drugs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garg, Aprajita; Lukk, Tiit; Kumar, Vidya
Phosphoethanolamine methyltransferases (PMTs) catalyze the three-step methylation of phosphoethanolamine to form phosphocholine, a critical step in the synthesis of phosphatidylcholine in a select number of eukaryotes including human malaria parasites, nematodes and plants. Genetic studies in the malaria parasite Plasmodium falciparum have shown that the methyltransferase PfPMT plays a critical function in parasite development and differentiation. The presence of PMT orthologs in other malaria parasites that infect humans and their absence in mammals make them ideal targets for the development of selective antimalarials with broad specificity against different Plasmodium species. Here we describe the X-ray structures and biochemical properties ofmore » PMT orthologs from Plasmodium vivax and Plasmodium knowlesi and show that both enzymes are inhibited by amodiaquine and NSC158011, two drugs with potent antimalarial activity. Metabolic studies in a yeast mutant that relies on PkPMT or PvPMT for survival demonstrated that these compounds inhibit phosphatidylcholine biosynthesis from ethanolamine. Our structural and functional data provide insights into the mechanism of catalysis and inhibition of PMT enzymes and set the stage for a better design of more specific and selective antimalarial drugs.« less
Chakravarthy, Divya; Muñoz, Amanda R.; Su, Angel; Hwang, Rosa F.; Keppler, Brian R.; Chan, Daniel E.; Halff, Glenn; Ghosh, Rita; Kumar, Addanki P.
2018-01-01
Reciprocal interaction between pancreatic stellate cells (PSCs) and cancer cells (PCCs) in the tumor microenvironment (TME) promotes tumor cell survival and progression to lethal, therapeutically resistant pancreatic cancer. The goal of this study was to test the ability of Palmatine (PMT) to disrupt this reciprocal interaction in vitro and examine the underlying mechanism of interaction. We show that PSCs secrete glutamine into the extracellular environment under nutrient deprivation. PMT suppresses glutamine-mediated changes in GLI signaling in PCCs resulting in the inhibition of growth and migration while inducing apoptosis by inhibition of survivin. PMT-mediated inhibition of (glioma-associated oncogene 1) GLI activity in stellate cells leads to suppression (collagen type 1 alpha 1) COL1A1 activation. Remarkably, PMT potentiated gemcitabine’s growth inhibitory activity in PSCs, PCCs and inherently gemcitabine-resistant pancreatic cancer cells. This is the first study that shows the ability of PMT to inhibit growth of PSCs and PCCs either alone or in combination with gemcitabine. These studies warrant additional investigations using preclinical models to develop PMT as an agent for clinical management of pancreatic cancer. PMID:29414301
Position-sensitive ``movie'' in situ neutron detector for the UCN τ experiment
NASA Astrophysics Data System (ADS)
Weaver, Hannah; UCNTau Collaboration
2016-09-01
Precision measurements of neutron β-decay parameters provide tests of fundamental theories in elementary particle physics and cosmology such as the Standard Model and Big Bang nucleosynthesis. In particular, the UCN τ experiment aims to measure the mean lifetime of ultracold neutrons confined in an asymmetric magneto-gravitational trap using an in situ neutron detector. This detector consists of a 20 nm film of 10B on top of a ZnS:Ag scintillating screen. The screen is readout using two photomultipliers which view an array of wavelength shifting fibers optically coupled to the scintillator. When the detector is lowered into the loaded trap, light is emitted due to the charged particles recoiling into the ZnS:Ag when neutrons absorb on the 10B. Phase space evolution in the stored neutron population can lead to apparent shifts in the measured neutron lifetime with the detector height. In order to quantify this systematic uncertainty, we are implementing a supplemental 64-channel position-sensitive PMT module with high quantum efficiency and fast time response to image the entire detector in situ during measurements. We have characterized a prototype using a ZnS screen and an α-particle source along with a prototype lens system and will report the results and future plans.
Bassett, Sandra F; Prapavessis, Harry
2011-07-01
The primary aim of this study was to test the effect of a Protection Motivation Theory (PMT)-based patient education intervention on physiotherapy patients' beliefs about their injury and physiotherapy, intentions to adhere, rehabilitation adherence, and ankle function. A secondary aim was to explore the relationships between the patients' injury and physiotherapy beliefs, intentions, adherence behaviours, and ankle function. A randomized controlled trial was undertaken in New Zealand; 71 people with ankle sprains were allocated to either PMT present video information or two control groups (non-PMT information about ankle sprains and no formal information) before commencing their course of physiotherapy. The two information groups watched a video about ankle sprains and physiotherapy before answering the Beliefs about Ankle Sprains and Physiotherapy Scale and behavioural intentions questionnaires that measured the PMT constructs. Adherence was assessed at each treatment and ankle function was measured before and after the physiotherapy program. After viewing the video, the PMT present information group's beliefs about severity, vulnerability, and response efficacy were significantly higher than the other two groups. The groups did not differ significantly on their self-efficacy, intentions, rehabilitation adherence, and post-physiotherapy program ankle function. Significant correlations existed between the patients' PMT-based beliefs and intentions, intentions and adherence, and adherence and post-physiotherapy ankle function. With the exception of self-efficacy, the findings indicate that persuasive information grounded in PMT does enhance physiotherapy patients' beliefs about their injury and treatment.
A new scalable modular data acquisition system for SPECT (PET)
NASA Astrophysics Data System (ADS)
Stenstrom, P.; Rillbert, A.; Bergquist, M.; Habte, F.; Bohm, C.; Larsson, S. A.
1998-06-01
Describes a modular decentralized data acquisition system that continuously samples shaped PMT pulses from a SPECT detector. The pulse waveform data are used by signal processors to accurately reconstruct amplitude and time for each scintillation event. Data acquisition for a PMT channel is triggered in two alternative ways, either when its own signal exceeds a selected digital threshold, or when it receives a trigger pulse from one of its neighboring PMTs. The triggered region is restricted to seven, thirteen or nineteen neighboring PMT channels. Each acquisition module supports three PMT channels and connects to all other modules and a reconstruction computer via Firewire to cover the 72 channels in the Stockholm University/Karolinska Hospital cylindrical SPECT camera.
NASA Astrophysics Data System (ADS)
Wang, Wengong; Wang, Guo; Yang, Jie; Zhang, Jing; Chen, Lixia; Weng, Chao; Zhang, Zhi-Guo; Li, Yongfang; Shen, Ping
2017-03-01
Two donor-acceptor (D-A) copolymers (PMT-FBT and PET-FBT) with alkoxythiophene-substituted benzo[1,2-b:4,5-b‧]dithiophene as donor unit and difluorobenzothiazole as acceptor unit, were synthesized and employed as donor material for polymer solar cells (PSCs). The comparative study showed that the type (methoxyl versus ethylenedioxyl) and the position (3- and 4-positons) of alkoxy substituents on thiophene side chains have great effects on the molecular geometries and optoelectronic properties of these copolymers. PSCs based on two polymers exhibit maximum power conversion efficiencies of 3.29% and 2.40%, with open-circuit voltage (Voc) values as high as 0.85 and 1.02 V for PMT-FBT and PET-FBT, respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boivin, Jonathan, E-mail: jonathan.boivin.1@ulaval.ca; Beaulieu, Luc; Beddar, Sam
Purpose: The authors’ objective was to systematically assess the performance of seven photodetectors used in plastic scintillation dosimetry. The authors also propose some guidelines for selecting an appropriate detector for a specific application. Methods: The plastic scintillation detector (PSD) consisted of a 1-mm diameter, 10-mm long plastic scintillation fiber (BCF-60), which was optically coupled to a clear 10-m long optical fiber of the same diameter. A light-tight plastic sheath covered both fibers and the scintillator end was sealed. The clear fiber end was connected to one of the following photodetectors: two polychromatic cameras (one with an optical lens and onemore » with a fiber optic taper replacing the lens), a monochromatic camera with an optical lens, a PIN photodiode, an avalanche photodiode (APD), or a photomultiplier tube (PMT). A commercially available W1 PSD was also included in the study, but it relied on its own fiber and scintillator. Each PSD was exposed to both low-energy beams (120, 180, and 220 kVp) from an orthovoltage unit and high-energy beams (6 and 23 MV) from a linear accelerator. Various dose rates were tested to identify the operating range and accuracy of each photodetector. Results: For all photodetectors, the relative uncertainty was less than 5% for dose rates higher than 3 mGy/s. The cameras allowed multiple probes to be used simultaneously, but they are less sensitive to low-light signals. The PIN, APD, and PMT had higher sensitivity, making them more suitable for low dose rate and out-of-field dose monitoring. The relative uncertainty of the PMT was less than 1% at the lowest dose rate achieved (0.10 mGy/s), suggesting that it was optimal for use in live dosimetry. Conclusions: For dose rates higher than 3 mGy/s, the PIN diode is the most effective photodetector in terms of performance/cost ratio. For lower dose rates, such as those seen in interventional radiology or high-gradient radiotherapy, PMTs are the optimal choice.« less
Design of a portable fluoroquinolone analyzer based on terbium-sensitized luminescence
NASA Astrophysics Data System (ADS)
Chen, Guoying
2007-09-01
A portable fluoroquinolone (FQ) analyzer is designed and prototyped based on terbium-sensitized luminescence (TSL). The excitation source is a 327-nm light emitting diode (LED) operated in pulsed mode; and the luminescence signal is detected by a photomultiplier tube (PMT). In comparison to a conventional xenon flashlamp, an LED is small, light, robust, and energy efficient. More importantly, its narrow emission bandwidth and low residual radiation reduce background signal. In pulse mode, an LED operates at a current 1-2 orders of magnitude lower than that of a xenon flashlamp, thus minimizing electromagnetic interference (EMI) to the detector circuitry. The PMT is gated to minimize its response to the light source. These measures lead to reduced background noise in time domain. To overcome pulse-to-pulse variation signal normalization is implemented based on individual pulse energy. Instrument operation and data processing are controlled by a computer running a custom LabVIEW program. Enrofloxacin (ENRO) is used as a model analyte to evaluate instrument performance. The integrated TSL intensity reveals a linear dependence up to 2 ppm. A 1.1-ppb limit of detection (LOD) is achieved with relative standard deviation (RSD) averaged at 5.1%. The background noise corresponds to ~5 ppb. At 19 lbs, this portable analyzer is field deployable for agriculture, environmental and clinical analyses.
Lippke, Sonia; Plotnikoff, Ronald C
2009-05-01
Two different theories of health behaviour have been chosen with the aim of theory integration: a continuous theory (protection motivation theory, PMT) and a stage model (transtheoretical model, TTM). This is the first study to test whether the stages of the TTM moderate the interrelation of PMT-variables and the mediation of motivation, as well as PMT-variables' interactions in predicting stage transitions. Hypotheses were tested regarding (1) mean patterns, stage pair-comparisons and nonlinear trends using ANOVAs; (2) prediction-patterns for the different stage groups employing multi-group structural equation modelling (MSEM) and nested model analyses; and (3) stage transitions using binary logistic regression analyses. Adults (N=1,602) were assessed over a 6 month period on their physical activity stages, PMT-variables and subsequent behaviour. (1) Particular mean differences and nonlinear trends in all test variables were found. (2) The PMT adequately fitted the five stage groups. The MSEM revealed that covariances within threat appraisal and coping appraisal were invariant and all other constrains were stage-specific, i.e. stage was a moderator. Except for self-efficacy, motivation fully mediated the relationship between the social-cognitive variables and behaviour. (3) Predicting stage transitions with the PMT-variables underscored the importance of self-efficacy. Only when threat appraisal and coping appraisal were high, stage movement was more likely in the preparation stage. Results emphasize stage-specific differences of the PMT mechanisms, and hence, support the stage construct. The findings may guide further theory building and research integrating different theoretical approaches.
NASA Astrophysics Data System (ADS)
Vasquez, Jaime; Saavedra, Arthur; Ramos, Roxana; Tavares, Pablo; Wade, Marcus; Fan, Sewan; Haag, Brooke
2013-04-01
Through the Research Scholars Institute, students of Hartnell Community College experimented with the application of avalanche photodiodes (APDs) as cosmic ray detectors during the summer of 2012. An APD detector was coupled with a 10 meter long wavelength shifting fiber (WSF) wrapped around a cylindrical plastic scintillator to maximize signal detection. A photomultiplier tube (PMT) was used in conjunction to detect the same scintillation light caused by incoming cosmic rays. Two APD detectors were evaluated to confirm the viability of the setup. In addition, a similar setup was recently utilized to implement multi-pixel photon counters (MPPCs) as readout detectors. Under this configuration, a high gain preamplifier was used to amplify the signals for both the MPPC and APD detectors. We report on our results characterizing the MPPC and discuss its overall performance. Compared to the APD, our findings suggest that the MPPC detector has greater sensitivity in detecting weak light signals, and can be used in place of the PMT for certain counting applications.
NASA Astrophysics Data System (ADS)
de Asmundis, R.; Barbarino, G.; Barbato, F. C. T.; Campajola, L.; De Rosa, G.; Fiorillo, G.; Migliozzi, P.; Mollo, C. M.; Rossi, B.; Vivolo, D.
2014-04-01
We invented (2007) the VSiPMT, a novel, high-gain, photo detector device and we publically proposed this idea in an International Conference for the first time at the 11th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD08) in Siena, triggering deep discussions on the feasibility of the device itself and on the convenience of such a solution. After several years spent in designing, evaluation, tests and eventually negotiations with some suppliers, we finally got a couple of prototypes of the Vacuum Silicon Photo Multiplier Tube (VSiPMT) made under our specifications by Hamamatsu. We present in this paper the most important results of characterization tests of the first prototypes of the VSiPMT.
Plotnikoff, Ronald C; Lippke, Sonia; Trinh, Linda; Courneya, Kerry S; Birkett, Nick; Sigal, Ronald J
2010-09-01
To investigate the utility of the protection motivation theory (PMT) for explaining physical activity (PA) in an adult population with type 1 diabetes (T1D) and type 2 diabetes (T2D). Cross-sectional and 6-month longitudinal analysis using PMT. Two thousand three hundred and eleven individuals with T1D (N=697) and T2D (N=1,614) completed self-report PMT constructs of vulnerability, severity, response efficacy, self-efficacy, and intention, and PA behaviour at baseline and 6-month follow-up. Multi-group structural equation modelling was conducted to: (1) test the fit of the PMT structure; (2) determine the similarities and differences in the PMT structure between the two types of diabetes; and (3) examine the explained variance and compare the strength of association of the PMT constructs in predicting PA intention and behaviour. The findings provide evidence for the utility of the PMT in both diabetes samples (chi(2)/df=1.27-4.08, RMSEA=.02-.05). Self-efficacy was a stronger predictor of intention (beta=0.64-0.68) than response efficacy (beta=0.14-0.16) in individuals with T1D or T2D. Severity was significantly related to intention (beta=0.06) in T2D individuals only, whereas vulnerability was not significantly related to intention or PA behaviour. Self-efficacy (beta's=0.20-0.28) and intention (beta's=0.12-0.30) were significantly associated with PA behaviour. Promotion of PA behaviour should primarily target self-efficacy to form intentions and to change behaviour. In addition, for individuals with T2D, severity information should be incorporated into PA intervention materials in this population.
Helander, Maria; Lochman, John; Högström, Jens; Ljótsson, Brjánn; Hellner, Clara; Enebrink, Pia
2018-04-01
For children with oppositional defiant disorder (ODD), Parent Management Training (PMT) is a recommended treatment in addition to child Cognitive Behavioral Therapy (child-CBT). There is however a lack of studies investigating the additive effect of group-based child-CBT to PMT for children between 8 and 12 years. The current study investigated the incremental effect of group-based child-CBT, based on the Coping Power Program, when added to the Swedish group-based PMT program KOMET. Outcomes were child behavior problems, child prosocial behavior, parenting skills and the moderating effect of child characteristics. One hundred and twenty children 8-12 years with ODD or Disruptive Behavioral Disorder NOS and their parents were randomized either to combined child-CBT and PMT (n = 63) or to PMT only (n = 57) in Swedish Child- and Adolescent Psychiatric settings. Participants were assessed pre- and post-treatment using semi-structured interviews and child- and parent ratings. After treatment, behavior problems were reduced in both groups. Prosocial behavior were significantly more improved in the combined treatment. Parenting skills were improved in both groups. In moderator analyses, behavior problems and prosocial behavior improved significantly more in the combined treatment compared to PMT only in the group of children with high levels of ODD symptoms. Copyright © 2018 Elsevier Ltd. All rights reserved.
SPE analysis of high efficiency PMTs for the DEAP-3600 dark matter detector
NASA Astrophysics Data System (ADS)
Olsen, Kevin; Hallin, Aksel; DEAP/CLEAN Collaboration
2011-09-01
The Dark matter Experiment using Argon Pulse-shape discrimination is a collaborative effort to develop a next-generation, tonne-scale dark matter detector at SNOLAB. The detector will feature a single-phase liquid argon (LAr) target surrounded by an array of 266 photomultiplier tubes (PMTs). A new high-efficiency Hamamatsu R877-100 PMT has been delivered to the University of Alberta for evaluation by the DEAP collaboration. The increase in efficiency could lead to a much greater light yield, but other experiments have reported a slower rise time [1],[2]. We have placed the PMT in a small dark box and had a base and preamplifier designed to be used with either an oscilloscope or a multi-channel analyzer. With this setup we have demonstrated the PMT's ability to distinguish single photo-electrons (SPE) and characterized the PMT by measuring the SPE pulse height spectrum, the peak-to-valley ratio, the dark pulse rate, the baseline, time resolution and SPE efficiency for varying the high voltage supplied to the PMT.
A Protection Motivation Theory-Based Scale for Tobacco Research among Chinese Youth
MacDonell, Karen; Chen, Xinguang; Yan, Yaqiong; Li, Fang; Gong, Jie; Sun, Huiling; Li, Xiaoming; Stanton, Bonita
2014-01-01
Rates of tobacco use among adolescents in China and other lower and middle-income countries remain high despite notable prevention and intervention programs. One reason for this may be the lack of theory-based research in tobacco use prevention in these countries. In the current study, a culturally appropriate 21-item measurement scale for cigarette smoking was developed based on the core constructs of Protection Motivation Theory (PMT). The scale was assessed among a sample of 553 Chinese vocational high school students. Results from correlational and measurement modeling analysis indicated adequate measurement reliability for the proposed PMT scale structure. The two PMT Pathways and the seven PMT constructs were significantly correlated with adolescent intention to smoke and actual smoking behavior. This study is the first to evaluate a PMT scale for cigarette smoking among Chinese adolescents. The scale provides a potential tool for assessing social cognitive processes underlying tobacco use. This is essential for understanding smoking behavior among Chinese youth and to support more effective tobacco use prevention efforts. Additional studies are needed to assess its utility for use with Chinese youth in other settings. PMID:24478933
Plotnikoff, Ronald C; Rhodes, Ryan E; Trinh, Linda
2009-11-01
The purpose of this study was to examine the Protection Motivation Theory (PMT) to predict physical activity (PA) behaviour in a large, population-based sample of adults. One thousand six hundred and two randomly selected individuals completed two telephone interviews over two consecutive six-month periods assessing PMT constructs. PMT explained 35 per cent and 20 per cent of the variance in intention and behaviour respectively. Coping cognitions as moderators of threat explained 1 per cent of the variance in intention and behaviour. Age and gender as moderators of threat did not provide additional variance in the models. We conclude that salient PMT predictors (e.g. self-efficacy) may guide the development of effective PA interventions in the general population.
Development of 10×10 Matrix-anode MCP-PMT
NASA Astrophysics Data System (ADS)
Yang, Jie; Li, Yongbin; Xu, Pengxiao; Zhao, Wenjin
2018-02-01
10×10 matrix-anode is developed by high-temperature co-fired ceramics (HTCC) technology. Based on the new matrix-anode, a new kind of photon counting imaging detector - 10×10 matrix-anode MCP-PMT is developed, and its performance parameters are tested. HTCC technology is suitable for the MCP-PMT's air impermeability and its baking process. Its response uniformity is better than the metal-ceramic or metal-glass sealing anode, and it is also a promising method to realize a higher density matrix-anode.
Grindley, Emma J; Zizzi, Samuel J; Nasypany, Alan M
2008-12-01
Protection motivation theory (PMT) has been used in more than 20 different health-related fields to study intentions and behavior, albeit primarily outside the area of injury rehabilitation. In order to examine and predict patient adherence behavior, this study was carried out to explore the use of PMT as a screening tool in a general sample of people with orthopedic conditions. New patients who were more than 18 years old and who were prescribed 4 to 8 weeks of physical therapy treatment (n=229) were administered a screening tool (Sports Injury Rehabilitation Beliefs Scale, Positive and Negative Affect Schedule, and a barriers checklist) prior to treatment. Participants' adherence was assessed with several attendance measures and an in-clinic assessment of behavior. Statistical analyses included correlation, chi-square, multiple regression, and discriminant function analyses. A variety of relationships among affect, barriers, and PMT components were evident. In-clinic behavior and attendance were influenced by affect, whereas dropout status was predicted by affect, severity, self-efficacy, and age. The screening tool used in this study may assist in identifying patients who are at risk for poor adherence and provide valuable information to enhance provider-patient relationships and foster patient adherence. However, it is recommended that more research be conducted to further understand the impact of variables on patient adherence and that the screening tool be enhanced to increase its predictive ability.
Hsieh, Hui-Lung; Kuo, Yu-Ming; Wang, Shiang-Ru; Chuang, Bi-Kun; Tsai, Chung-Hung
2016-12-23
The personal health record (PHR) is a system that enables borderless medical care services by combining technological innovation and human consideration. This study explored factors affecting the adoption of PHR from technical, medical, and social perspectives according to the Protection Motivation Theory (PMT) and Unified Theory of Acceptance and Use of Technology (UTAUT) model. A survey using a structured questionnaire was subsequently conducted, which produced the following results: (1) The PMT and UTAUT were effective at predicting PHR usage behaviors; (2) Perceived ease-of-use was the most decisive factor influencing the use of PHR, followed by self-efficacy and perceived usefulness; and (3) Behavioral intention for PHR was significantly and positively correlated with usage behavior. From the obtained results, this study recommends that health authorities and medical institutions promote self-efficacy in the use of PHR to improve the levels of behavioral intention and usage behavior among the people. Additionally, medical care institutions are recommended to promote health management and preventive healthcare concepts to help improve public acceptance of the PHR system as a means to self-manage their health. Finally, community centers, medical institutions, and health authorities are urged to work together to enhance public medical knowledge and pool resources for the PHR system, both of which are essential for improving the popularity of the PHR, public quality of life, and the effectiveness of health management.
Ellis, Mark B; Gridley, Daniel; Lal, Suresh; Nair, Geetha R; Feiz-Erfan, Iman
2016-05-01
Phosphaturic mesenchymal tumor (mixed connective tissue variant) (PMT-MCT) are tumors that may cause tumor-induced osteomalacia and rarely appear intracranially. The authors describe the case of an 8-year-old girl who was found to have PMT-MCT with involvement of the cerebellar hemisphere and a small tumor pedicle breaching the dura mater and involving the skull. This was removed surgically in gross-total fashion without further complication. Histologically the tumor was confirmed to be a PMT-MCT. There was no evidence of tumor-induced osteomalacia. At the 42-month follow-up, the patient is doing well, has no abnormalities, and is free of recurrence. PMT-MCTs are rare tumors that may involve the brain parenchyma. A gross-total resection may be effective to cure these lesions.
NASA Astrophysics Data System (ADS)
Maurya, Neha; ud din Parray, Mehraj; Maurya, Jitendra Kumar; Kumar, Amit; Patel, Rajan
2018-06-01
The binding nature of amphiphilic drugs viz. promethazine hydrochloride (PMT) and adiphenine hydrochloride (ADP), with human hemoglobin (Hb) was unraveled by fluorescence, absorbance, time resolved fluorescence, fluorescence resonance energy transfer (FRET) and circular dichroism (CD) spectral techniques in combination with molecular docking and molecular dynamic simulation methods. The steady state fluorescence spectra indicated that both PMT and ADP quenches the fluorescence of Hb through static quenching mechanism which was further confirmed by time resolved fluorescence spectra. The UV-Vis spectroscopy suggested ground state complex formation. The activation energy (Ea) was observed more in the case of Hb-ADP than Hb-PMT interaction system. The FRET result indicates the high probability of energy transfer from β Trp37 residue of Hb to the PMT (r = 2.02 nm) and ADP (r = 2.33 nm). The thermodynamic data reveal that binding of PMT with Hb are exothermic in nature involving hydrogen bonding and van der Waal interaction whereas in the case of ADP hydrophobic forces play the major role and binding process is endothermic in nature. The CD results show that both PMT and ADP, induced secondary structural changes of Hb and unfold the protein by losing a large helical content while the effect is more pronounced with ADP. Additionally, we also utilized computational approaches for deep insight into the binding of these drugs with Hb and the results are well matched with our experimental results.
McGowan, Erin L; Prapavessis, Harry
2010-12-01
Using a Protection Motivation Theory (PMT) framework, this study examined whether factual colon cancer information is a meaningful source of exercise motivation for relatives of patients with colon cancer. One hundred sixty-six inactive relatives were randomly assigned to one of two treatment conditions: PMT group (intervention); and non-PMT group (attention control). At baseline (T1) participants completed demographic information, a questionnaire designed to assess their beliefs toward exercise and colon cancer as well as their exercise intentions. At T2 (one week following T1) participants watched one of two DVD videos that were created for the study. The intervention DVD contained exercise and colon cancer information that was yoked within the four major components of PMT: perceived vulnerability (PV); perceived severity (PS); response efficacy (RE); and self-efficacy (SE), while the attention control DVD contained general diet and cancer information. Immediately following watching the DVD, participants completed the same measures as in T1. Participants assigned to the PMT intervention group showed significant improvement in PV, RE, SE and exercise intentions, whereas participants assigned to the attention control group showed significant improvement only in RE. RE, SE, and PS made significant and unique contributions to prediction of exercise intention. Overall, the results of the present study demonstrate that a single exposure media intervention grounded in a PMT framework can change individuals' exercise and colon cancer beliefs, as well as change their exercise intentions. Implications of these findings and direction for future research are discussed.
microPMT-A New Photodetector for Gamma Spectrometry and Fast Timing?
NASA Astrophysics Data System (ADS)
Szczęśniak, T.; Grodzicka, M.; Moszyński, M.; Szawłowski, M.; Baszak, J.
2014-10-01
A micro photomultiplier (microPMT or μPMT) works like a classic photomultiplier but the whole device is made directly in a silicon wafer sandwiched between two glass layers. A microPMT has dimensions of only 13x10x2 mm and its photocathode has a size of 3x1 mm. The aim of the work is to check usefulness of a microPMT in gamma spectrometry with scintillators and fast timing. In the first part of the study analysis of the energy resolution obtained with 3x3x1 mm LSO, BGO and CsI(Tl) scintillators is made. The recorded values for 662 keV are equal to 22.9% and 13.5% for CsI and LSO, respectively. The light pulse shapes of a single photoelectron and scintillation signal of LSO are also shown. The important part of the study is measurement of the number of photoelectrons and estimation of the excess noise factor. Only 2200 phe/MeV were obtained for LSO coupled with the tested microPMT. The calculated excess noise factor is equal to 1.4. In the second part, measurements of the time jitter and timing resolution with LSO crystal for 511 keV annihilation quanta are reported. The timing characteristics of the tested device is poor. Its time jitter equals to 1.5 ns, whereas timing resolution for 22Na is 620 ps. All the results are compared with data obtained with classic PMTs.
Maurya, Neha; Ud Din Parray, Mehraj; Maurya, Jitendra Kumar; Kumar, Amit; Patel, Rajan
2018-06-15
The binding nature of amphiphilic drugs viz. promethazine hydrochloride (PMT) and adiphenine hydrochloride (ADP), with human hemoglobin (Hb) was unraveled by fluorescence, absorbance, time resolved fluorescence, fluorescence resonance energy transfer (FRET) and circular dichroism (CD) spectral techniques in combination with molecular docking and molecular dynamic simulation methods. The steady state fluorescence spectra indicated that both PMT and ADP quenches the fluorescence of Hb through static quenching mechanism which was further confirmed by time resolved fluorescence spectra. The UV-Vis spectroscopy suggested ground state complex formation. The activation energy (E a ) was observed more in the case of Hb-ADP than Hb-PMT interaction system. The FRET result indicates the high probability of energy transfer from β Trp37 residue of Hb to the PMT (r=2.02nm) and ADP (r=2.33nm). The thermodynamic data reveal that binding of PMT with Hb are exothermic in nature involving hydrogen bonding and van der Waal interaction whereas in the case of ADP hydrophobic forces play the major role and binding process is endothermic in nature. The CD results show that both PMT and ADP, induced secondary structural changes of Hb and unfold the protein by losing a large helical content while the effect is more pronounced with ADP. Additionally, we also utilized computational approaches for deep insight into the binding of these drugs with Hb and the results are well matched with our experimental results. Copyright © 2018 Elsevier B.V. All rights reserved.
Wide Dynamic Range Array Detector for Absorbance and Rotation Spectrometry.
1983-07-05
target tube (SIT) is used. With the SIT, as with the PMT, the sensitivity and spectral response are dependent on the choice of photocathode material ...refer to the same material under the same conditions. Figure 3 is a block diagram of the optical setup as configured for measurement of optical rotation...21401 Research Triangle Park, N.C. 27709 1 Mr. John Boyle Mr. Vincent Schaper Materials Branch DTNSRDC Code 2803 Naval Ship Engineering Center Annapolis
Single-photon counting multicolor multiphoton fluorescence microscope.
Buehler, Christof; Kim, Ki H; Greuter, Urs; Schlumpf, Nick; So, Peter T C
2005-01-01
We present a multicolor multiphoton fluorescence microscope with single-photon counting sensitivity. The system integrates a standard multiphoton fluorescence microscope, an optical grating spectrograph operating in the UV-Vis wavelength region, and a 16-anode photomultiplier tube (PMT). The major technical innovation is in the development of a multichannel photon counting card (mC-PhCC) for direct signal collection from multi-anode PMTs. The electronic design of the mC-PhCC employs a high-throughput, fully-parallel, single-photon counting scheme along with a high-speed electrical or fiber-optical link interface to the data acquisition computer. There is no electronic crosstalk among the detection channels of the mC-PhCC. The collected signal remains linear up to an incident photon rate of 10(8) counts per second. The high-speed data interface offers ample bandwidth for real-time readout: 2 MByte lambda-stacks composed of 16 spectral channels, 256 x 256 pixel image with 12-bit dynamic range can be transferred at 30 frames per second. The modular design of the mC-PhCC can be readily extended to accommodate PMTs of more anodes. Data acquisition from a 64-anode PMT has been verified. As a demonstration of system performance, spectrally resolved images of fluorescent latex spheres and ex-vivo human skin are reported. The multicolor multiphoton microscope is suitable for highly sensitive, real-time, spectrally-resolved three-dimensional imaging in biomedical applications.
Norman, Paul; Searle, Aidan; Harrad, Richard; Vedhara, Kav
2003-02-01
This study reports an application of protection motivation theory (PMT) to the prediction of parental adherence to eye patching recommendations for children with amblyopia over a 2-month period. The study also considered the role of past behaviour in PMT. A total of 151 parents of children with amblyopia who were attending follow-up appointments for orthoptic treatment participated. They completed questionnaires based on PMT to assess their beliefs about amblyopia and eye patching. Of the parents, 105 were contacted again at 2-month follow-up to obtain a measure of adherence to the recommended treatment for their child. PMT was found to be predictive of adherence intentions and behaviour at 2-month follow-up. Regression analyses revealed perceived vulnerability, response efficacy and self-efficacy to be significant predictors of protection motivation, whereas perceived vulnerability and response costs were significant predictors of adherence behaviour. Past adherence behaviour was found to have a direct effect on future adherence behaviour over and above the influence of PMT. The results are discussed in relation to the sufficiency of PMTas a model of adherence behaviour. The practical implications for attempts to increase adherence to eye patching among children with amblyopia are outlined.
Compact Ozone Lidar for Atmospheric Ozone and Aerosol Measurements
NASA Technical Reports Server (NTRS)
Marcia, Joel; DeYoung, Russell J.
2007-01-01
A small compact ozone differential absorption lidar capable of being deployed on a small aircraft or unpiloted atmospheric vehicle (UAV) has been tested. The Ce:LiCAF tunable UV laser is pumped by a quadrupled Nd:YLF laser. Test results on the laser transmitter demonstrated 1.4 W in the IR and 240 mW in the green at 1000 Hz. The receiver consists of three photon-counting channels, which are a far field PMT, a near field UV PMT, and a green PMT. Each channel was tested for their saturation characteristics.
Sibout, Richard; Le Bris, Philippe; Cézard, Laurent
2016-01-01
Grass lignins can contain up to 10% to 15% by weight of p-coumaric esters. This acylation is performed on monolignols under the catalysis of p-coumaroyl-coenzyme A monolignol transferase (PMT). To study the impact of p-coumaroylation on lignification, we first introduced the Brachypodium distachyon Bradi2g36910 (BdPMT1) gene into Arabidopsis (Arabidopsis thaliana) under the control of the constitutive maize (Zea mays) ubiquitin promoter. The resulting p-coumaroylation was far lower than that of lignins from mature grass stems and had no impact on stem lignin content. By contrast, introducing either the BdPMT1 or the Bradi1g36980 (BdPMT2) gene into Arabidopsis under the control of the Arabidopsis cinnamate-4-hydroxylase promoter boosted the p-coumaroylation of mature stems up to the grass lignin level (8% to 9% by weight), without any impact on plant development. The analysis of purified lignin fractions and the identification of diagnostic products confirmed that p-coumaric acid was associated with lignins. BdPMT1-driven p-coumaroylation was also obtained in the fah1 (deficient for ferulate 5-hydroxylase) and ccr1g (deficient for cinnamoyl-coenzyme A reductase) lines, albeit to a lower extent. Lignins from BdPMT1-expressing ccr1g lines were also found to be feruloylated. In Arabidopsis mature stems, substantial p-coumaroylation of lignins was achieved at the expense of lignin content and induced lignin structural alterations, with an unexpected increase of lignin units with free phenolic groups. This higher frequency of free phenolic groups in Arabidopsis lignins doubled their solubility in alkali at room temperature. These findings suggest that the formation of alkali-leachable lignin domains rich in free phenolic groups is favored when p-coumaroylated monolignols participate in lignification in a grass in a similar manner. PMID:26826222
Putrescine N-Methyltransferase in Cultured Roots of Hyoscyamus albus1
Hibi, Naruhiro; Fujita, Toshihiro; Hatano, Mika; Hashimoto, Takashi; Yamada, Yasuyuki
1992-01-01
Biosynthesis of tropane alkaloids is thought to proceed by way of the diamine putrescine, followed by its methylation by putrescine N-methyltransferase (PMT; EC 2.1.1.53). High PMT activities were found in branch roots and/or cultured roots of several solanaceous plants. PMT was partially purified and characterized from cultured roots of Hyoscyamus albus that contain hyoscyamine as the main alkaloid. Initial velocity studies and product inhibition patterns of PMT are consistent with an ordered bi-bi mechanism, in which the Km values for putrescine and S-adenosyl-l-methionine are 277 and 203 μm, respectively, and the Ki value for S-adenosyl-l-homocysteine is 110 μm. PMT efficiently N-methylated amines that have at least two amino groups separated by three or four methylene groups. Monoamines were good competitive inhibitors of PMT, among which n-butylamine, cyclohexylamine, and exo-2-aminonorbornane were most inhibitory, with respective Ki values of 11.0, 9.1, and 10.0 μm. When n-butylamine was fed to root cultures of H. albus, the alkamine intermediates (tropinone, tropine, and pseudotropine) drastically decreased at 1 mm of the exogenous monoamine, and the hyoscyamine content decreased by 52% at 6 mm, whereas the contents of 6β-hydroxyhyoscyamine and scopolamine did not change. Free and conjugated forms of polyamines were also measured. The n-butylamine treatment caused a large increase in the putrescine content (especially in the conjugated pool), and the spermine content also increased slightly, whereas the spermidine content decreased slightly. The increase in the putrescine pool size (approximately 40 nmol/mg dry weight) was large enough to account for the decrease in the total alkaloid pool size. Similar results were also obtained in root cultures of Datura stramonium. These studies further support the role of PMT as the first committed enzyme specific to alkaloid biosynthesis. Images Figure 8 PMID:16653064
Peters, Sarah; Calam, Rachel; Harrington, Richard
2005-04-01
The effectiveness of parent management training (PMT) as a treatment for child behaviour problems is reduced by high attrition rates. One difficulty with engaging mothers is that, by definition, PMT is directed at the parent, yet many parents believe the cause of the problem lies within the child. Hence the model of therapy offered contradicts their understanding about the cause and nature of the problem. Moreover, the emotional consequence of holding child-responsibility causal attributions is associated with high expressed emotion (EE), a known predictor of poor compliance with therapy in other child psychiatric disorders. Seventy-five consecutive referrals of mothers to a PMT programme were recruited. EE was assessed using the Camberwell Family Interview methodology. Spontaneous causal attributions about their child's problem behaviour were collected from the same interview material and independently coded using the Leeds Attributional Coding System. Attendance data at the PMT programme was collected following completion of programmes. Contrary to expectations, mothers who made child-responsibility attributions and were highly critical about their child's behaviour were no more likely than non-blaming, low EE parents to drop out prematurely from a course of PMT. However, expressing an understanding of their own role in managing their child's behaviour was predictive of attendance. Two factors were, however, more closely associated with greater attrition: having been offered a clinical diagnosis and being from a lower socio-economic family. Socio-economic factors should be viewed as barriers to uptake of services and successful strategies for increasing engagement of families are likely to be economical rather than psychological. However, although the causal attributions mothers make about their child's behaviour did not predict whether they were likely to attend PMT, an exploratory analysis found evidence to suggest that successful engagement with PMT begins early in the referral process and that referring clinicians should ensure treatment options are aligned with diagnoses provided.
Scaglioni, Mario F; Barth, Andrè A; Chen, Yen-Chou
2018-06-19
The primary closure of the vertical posteromedial thigh (vPMT) free flap donor site is very important to minimize donor site morbidity and maximize cosmetic appearance. However, sometimes due to the dimension of the defect, a vPMT flap is wider than the 8-10 cm requirement. The authors report their experience with the third perforator of the profunda femoris artery (PFA) during the vPMT free flap donor-site closure. Between January 2016 and December 2017, 5 patients underwent reconstruction of lower extremity (2 pts.) and head and neck (3 pts.) area with the free vPMT flaps. Attempts to close the vPMT free flap donor site directly failed due to the flaps' width (average: 11 cm) and pedicled perforator flaps based on the third perforator of the PFA at the distal thigh were harvested to close the defect primary without the use of a skin graft. The size of perforator flap based on 3rd perforator of PFA was on average 6 cm × 4 cm (ranged: 4-8 cm × 3-6 cm). In all patients, the third perforator of the PFA was identified and the perforator diameter was on average 2.0 mm (range, 1.8-2.2 mm). All perforators were musculocutaneous and single. The dimensions of the flaps were on average 6 cm × 4 cm (range: 4 to 8 cm × 3 to 6 cm). All flaps healed uneventfully without complications and the patients were satisfied with cosmetic and functional results at 6 months follow-up. The third perforator of the PFA may be an option to ensure primary closure of the PMT flap donor site, when a larger flap for reconstruction is needed with subsequent impossibility to achieve primary closure of the donor site. © 2018 Wiley Periodicals, Inc.
Bui, Linh; Mullan, Barbara; McCaffery, Kirsten
2013-01-01
An appropriate theoretical framework may be useful for guiding the development of physical activity interventions. This review investigates the effectiveness of the protection motivation theory (PMT), a model based on the cognitive mediation processes of behavioral change, in the prediction and promotion of physical activity participation. A literature search was conducted using the databases MEDLINE, PsycINFO, PubMed, and Web of Science, and a manual search was conducted on relevant reference lists. Studies were included if they tested or applied the PMT, measured physical activity, and sampled from healthy populations. A total of 20 studies were reviewed, grouped into four design categories: prediction, stage discrimination, experimental manipulation, and intervention. The results indicated that the PMT's coping appraisal construct of self-efficacy generally appears to be the most effective in predicting and promoting physical activity participation. In conclusion, the PMT shows some promise, however, there are still substantial gaps in the evidence.
Zhang, Yuxuan; Ramirez, Rocio A; Li, Hongdi; Liu, Shitao; An, Shaohui; Wang, Chao; Baghaei, Hossain; Wong, Wai-Hoi
2010-02-01
A lower-cost high-sensitivity high-resolution positron emission mammography (PEM) camera is developed. It consists of two detector modules with the planar detector bank of 20 × 12 cm(2). Each bank has 60 low-cost PMT-Quadrant-Sharing (PQS) LYSO blocks arranged in a 10 × 6 array with two types of geometries. One is the symmetric 19.36 × 19.36 mm(2) block made of 1.5 × 1.5 × 10 mm(3) crystals in a 12 × 12 array. The other is the 19.36 × 26.05 mm(2) asymmetric block made of 1.5 × 1.9 × 10 mm(3) crystals in 12 × 13 array. One row (10) of the elongated blocks are used along one side of the bank to reclaim the half empty PMT photocathode in the regular PQS design to reduce the dead area at the edge of the module. The bank has a high overall crystal packing fraction of 88%, which results in a very high sensitivity. Mechanical design and electronics have been developed for low-cost, compactness, and stability purposes. Each module has four Anger-HYPER decoding electronics that can handle a count-rate of 3 Mcps for single events. A simple two-module coincidence board with a hardware delay window for random coincidences has been developed with an adjustable window of 6 to 15 ns. Some of the performance parameters have been studied by preliminary tests and Monte Carlo simulations, including the crystal decoding map and the 17% energy resolution of the detectors, the point source sensitivity of 11.5% with 50 mm bank-to-bank distance, the 1.2 mm-spatial resolutions, 42 kcps peak Noise Equivalent Count Rate at 7.0-mCi total activity in human body, and the resolution phantom images. Those results show that the design goal of building a lower-cost, high-sensitivity, high-resolution PEM detector is achieved.
Sinonasal phosphaturic mesenchymal tumor: Case report and systematic review
Cain, Rachel B.; McCullough, Ann E.; Hoxworth, Joseph M.; Lal, Devyani
2014-01-01
We report a case of sinonasal phosphaturic mesenchymal tumor (PMT) and conduct a systematic review of the literature to highlight a unique paraneoplastic syndrome associated with PMT. We used English language publications from Medline and Cochrane databases (1970–2013) as data sources. A systematic review of the literature was conducted. All reported cases of head and neck PMTs were included. The presence or absence of the associated paraneoplastic syndrome was noted. We found 33 cases of PMT in the head and neck reported in the literature, 17 of which occurred in the sinonasal area. Approximately 5% of all PMTs are located in the head and neck. Just greater than half are concentrated in the sinonasal area, and the remaining involve various bony and soft tissue structures of the head and neck. PMT is sometimes associated with a paraneoplastic syndrome of tumor-induced (oncogenic) osteomalacia (TIO) causing bone pain, muscle weakness, and pathologic fractures. We present the 18th reported case of sinonasal PMT. A smooth mucosa-covered midline intraseptal mass filling the posterior nasal cavity with destruction and erosion of the skull base was found in an adult male. The patient underwent successful endoscopic resection with wide negative margins and is without recurrence at 24-month follow-up. PMT is a benign, locally aggressive tumor with rare malignant transformation. Knowledge of the bony invasion and destruction caused by this tumor is essential in planning surgical resection with wide negative margins. Familiarity with the associated TIO is essential to investigate for and manage any associated bony morbidity. PMID:25565053
Li, Xiaoming; Lin, Danhua; Wang, Bo; Du, Hongfei; Tam, Cheuk Chi; Stanton, Bonita
2014-08-01
Our objective was to evaluate the efficacy of a cultural adaptation of a social cognitive theory-based HIV behavioral prevention program among young rural-to-urban migrants in China. The intervention design and assessment were guided by the Protection Motivation Theory (PMT). The intervention was evaluated through a randomized controlled trial with 6-month and 12-month follow-ups. The primary behavioral outcome was the use of condoms. Other outcome measures include HIV knowledge, condom use knowledge, HIV-related perceptions (PMT constructs), and intention to use condom. The mixed-effects regression models for condom use with regular partners indicated that overall frequency of condom use, condom use in last three sexual acts and proper condom use increased over time for the participants but the increases were significantly greater among the intervention group than the control group at 6-month and 12-month follow-ups. The mixed-effects models for HIV-related perceptions indicated that extrinsic rewards, intrinsic rewards, and response costs decreased while vulnerability, severity, response efficacy, and self-efficacy increased over time for the intervention group. The increases in HIV knowledge, condom use knowledge, and intention to use condom were also significantly greater among the intervention group than the control group. The data in the current study suggested efficacy of a social cognitive theory-based behavioral intervention in increasing condom use among young migrants in China. The intervention also increased protective perceptions and decreased risk perception posited by the theory (i.e., PMT).
Hsieh, Hui-Lung; Kuo, Yu-Ming; Wang, Shiang-Ru; Chuang, Bi-Kun; Tsai, Chung-Hung
2016-01-01
The personal health record (PHR) is a system that enables borderless medical care services by combining technological innovation and human consideration. This study explored factors affecting the adoption of PHR from technical, medical, and social perspectives according to the Protection Motivation Theory (PMT) and Unified Theory of Acceptance and Use of Technology (UTAUT) model. A survey using a structured questionnaire was subsequently conducted, which produced the following results: (1) The PMT and UTAUT were effective at predicting PHR usage behaviors; (2) Perceived ease-of-use was the most decisive factor influencing the use of PHR, followed by self-efficacy and perceived usefulness; and (3) Behavioral intention for PHR was significantly and positively correlated with usage behavior. From the obtained results, this study recommends that health authorities and medical institutions promote self-efficacy in the use of PHR to improve the levels of behavioral intention and usage behavior among the people. Additionally, medical care institutions are recommended to promote health management and preventive healthcare concepts to help improve public acceptance of the PHR system as a means to self-manage their health. Finally, community centers, medical institutions, and health authorities are urged to work together to enhance public medical knowledge and pool resources for the PHR system, both of which are essential for improving the popularity of the PHR, public quality of life, and the effectiveness of health management. PMID:28025557
NASA Astrophysics Data System (ADS)
Barber, Corinne; DIRC at EIC Collaboration
2015-10-01
The High-B test facility at Thomas Jefferson National Accelerator Facility allows researchers to evaluate the gain of compact photon sensors, such as Micro-Channel-Plate Photomultipliers (MCP-PMTs), in magnetic fields up to 5 T. These ongoing studies support the development of a Detector of Internally Reflected Cherenkov light (DIRC) to be used in an Electron Ion Collider (EIC). Here, we present our summer 2015 activities to upgrade and improve the facility, and we show results for MCP-PMT gain changes in high B-fields. To monitor the light stability delivered to the MCP-PMTs being tested, we implemented a Silicon Photomultiplier (SiPM) in the setup and calibrated the ADC reading this sensor. A 405-nm Light-Emitting Diode (LED) housed in an optical tube compatible with neutral density filters was also installed. The filters provide an alternative way of reducing the light output of the LED to operate the MCP-PMTs in a single-photon mode. We calibrated a set of filters by means of a photodiode and measured the photon flux at multiple positions relative to the LED. This information helped us to design 3D-printed holders unique to each MCP-PMT so that the photocathode receives the greatest amount of light. The improvements to the setup allow for more precise PMT gain evaluation. This team includes 7 collaborators/co-authors besides myself: Yordanka Ilieva, Kijun Park, Greg Kalicy, Carl Zorn, Pawel Nadel-Turonski, Tongtong Cao, and Lee.
Gain control of photomultiplier tubes used in detecting differential absorption lidar returns
NASA Technical Reports Server (NTRS)
Allen, Robert J. (Inventor)
1989-01-01
A technique for controlling the gain of a photomultiplier tube (PMT) 20. A voltage divider (resistors 45-49 in FIG. 1 and zener diodes 60-65 in FIG. 3) is used to control the potentials on dynodes 5, 7, and 9 of PMT 20. Transistor switches 53 and 58 provide the control of the voltage divider in FIG. 1 and photodiodes 66, 67 and 70 provide the control in FIG. 3. The gain control of PMT 20 is in the range from 100% to less than 0.001% (100,000 to 1).
Fast photomultiplier tube gating system for underwater laser detector
NASA Astrophysics Data System (ADS)
Lei, Xuanhua; Yang, Kecheng; Rao, Jionghui; Zhang, Xiaohui; Xia, Min; Zheng, Yi; Li, Wei
2007-01-01
Laser will attenuate during its propagation in water and also be backward scattered by water when it is used to detect bubbles in the ocean. Meanwhile backward scattering intensity of the bubbles is feeble, its dynamic range reaches to the order of 6, which saturates PMT and its post-treatment circuit. Timely gating system is used to solve the problem. The system contains pulsed laser and gating PMT receiver. The wavelength of the laser is 532nm, with pulse width of several nanometers. Its operational delay is matched with the time period between laser traveling forward and back after scattered by the target. By doing this, the light scattered by other object is eliminated, dynamic range of the signal reduces, and consequently SNR increases. In order to avoid Signal Induced Noise(SIN), we choose PMT R1333 having no HA coating. TTL logical level, which is used as gating signal, controls the first dynode voltage of PMT to implement gating. Gating speed is about 100ns, of which the width is tunable. By carefully designing the electronic system, SNR is eliminated to a level as low as possible, and the output signal of PMT is fast integrated in order to reduce the influences of signal induced by opening the gate.
NASA Astrophysics Data System (ADS)
Liu, Qiaofei; Chen, Yu; Li, Weiwei; Liu, Yang; Han, Juan; Wen, Xiaoxia; Liao, Yuncheng
2016-06-01
A 2-year field experiment was conducted on maize (Zea mays L.) to explore effective ways to decrease soil CO2 emissions and increase grain yield. Treatments established were: (1) no mulching with urea, (2) no mulching with controlled release fertiliser (CRF), (3) transparent plastic-film mulching (PMt) with urea, (4) PMt with CRF, (5) black plastic-film mulching (PMb) with urea, and (6) PMb with CRF. During the early growth stages, soil CO2 emissions were noted as PMt > PMb > no mulching, and this order was reversed in the late growth stages. This trend was the result of topsoil temperature dynamics. There were no significant correlations noted between soil CO2 emissions and soil temperature and moisture. Cumulative soil CO2 emissions were higher for the PMt than for the PMb, and grain yield was higher for the PMb treatments than for the PMt or no mulching treatments. The CRF produced higher grain yield and inhibited soil CO2 emissions. Soil CO2 emissions per unit grain yield were lower for the BC treatment than for the other treatments. In conclusion, the use of black plastic-film mulching and controlled release fertiliser not only increased maize yield, but also reduced soil CO2 emissions.
LSNR Airborne LIDAR Mapping System Design and Early Results (Invited)
NASA Astrophysics Data System (ADS)
Shrestha, K.; Carter, W. E.; Slatton, K. C.
2009-12-01
Low signal-to-noise ratio (LSNR) detection techniques allow for implementation of airborne light detection and range (LIDAR) instrumentation aboard platforms with prohibitive power, size, and weight restrictions. The University of Florida has developed the Coastal Area Tactical-mapping System (CATS), a prototype LSNR LIDAR system capable of single photon laser ranging. CATS is designed to operate in a fixed-wing aircraft flying 600 m above ground level, producing 532 nm, 480 ps, 3 μJ output pulses at 8 kHz. To achieve continuous coverage of the terrain with 20 cm spatial resolution in a single pass, a 10x10 array of laser beamlets is scanned. A Risley prism scanner (two rotating V-coated optical wedges) allows the array of laser beamlets to be deflected in a variety of patterns, including conical, spiral, and lines at selected angles to the direction of flight. Backscattered laser photons are imaged onto a 100 channel (10x10 segmented-anode) photomultiplier tube (PMT) with a micro-channel plate (MCP) amplifier. Each channel of the PMT is connected to a multi-stop 2 GHz event timer. Here we report on tests in which ranges for known targets were accumulated for repeated laser shots and statistical analyses were applied to evaluate range accuracy, minimum separation distance, bathymetric mapping depth, and atmospheric scattering. Ground-based field test results have yielded 10 cm range accuracy and sub-meter feature identification at variable scan settings. These experiments also show that a secondary surface can be detected at a distance of 15 cm from the first. Range errors in secondary surface identification for six separate trials were within 7.5 cm, or within the timing resolution limit of the system. Operating at multi-photon sensitivity may have value for situations in which high ambient noise precludes single-photon sensitivity. Low reflectivity targets submerged in highly turbid waters can cause detection issues. CATS offers the capability to adjust the sensitivity of the sensor by changing the PMT supply voltage. For heavily turbid water, the multi-photon state (2300 V, 2.5*10^5 gain) was not sufficient for feature identification. Extraction of the bottom signal in a heavily turbid suspension necessitated maximum MCP-PMT gain (2500 V, 8*10^5 gain). Extrapolation of bathymetric test results suggest that the density of data points from the sea bottom should be sufficient to establish near-shore depths (up to 5 m) at a spatial resolution of 1 meter, in moderately turbid water. Initial airborne tests over fresh water lakes in central Florida indicate that scan patterns containing near nadir laser points produce strong returns from the surface of the water that cause oscillations in the PMT—preventing the detection of the lake bottom in shallow clear water. These results suggest that it may be necessary to tilt the sensor head in its mount, or use a scan pattern that does not include nadir points, such as a circular scan, for bathymetric mapping. Additional tests are ongoing to optimize the performance of the CATS LSNR airborne LIDAR system for both high spatial resolution terrain mapping and shallow water bathymetric mapping.
NASA Astrophysics Data System (ADS)
Li, H.; Wong, Wai-Hoi; Zhang, N.; Wang, J.; Uribe, J.; Baghaei, H.; Yokoyama, S.
1999-06-01
Electronics for a prototype high-resolution PET camera with eight position-sensitive detector modules has been developed. Each module has 16 BGO (Bi/sub 4/Ge/sub 3/O/sub 12/) blocks (each block is composed of 49 crystals). The design goals are component and space reduction. The electronics is composed of five parts: front-end analog processing, digital position decoding, fast timing, coincidence processing and master data acquisition. The front-end analog circuit is a zone-based structure (each zone has 3/spl times/3 PMTs). Nine ADCs digitize integration signals of an active zone identified by eight trigger clusters; each cluster is composed of six photomultiplier tubes (PMTs). A trigger corresponding to a gamma ray is sent to a fast timing board to obtain a time-mark, and the nine digitized signals are passed to the position decoding board, where a real block (four PMTs) can be picked out from the zone for position decoding. Lookup tables are used for energy discrimination and to identify the gamma-hit crystal location. The coincidence board opens a 70-ns initial timing window, followed by two 20-ns true/accidental time-mark lookup table windows. The data output from the coincidence board can be acquired either in sinogram mode or in list mode with a Motorola/IRONICS VME-based system.
Wang, Li; Yan, Lan; Li, Xing Xing; Xu, Guo Tong; An, Mao Mao; Jiang, Yuan Ying
2015-01-01
Candida albicans is the most common cause of invasive fungal infections in humans. The C. albicans cell wall proteins play an important role in crucial host-fungus interactions and might be ideal vaccine targets to induce protective immune response in host. Meanwhile, protein that is specific to C. albicans is also an ideal target of vaccine. In this study, 11 proteins involving cell wall biosynthesis, yeast-to-hypha formation, or specific to C. albicans were chosen and were successfully cloned, purified and verified. The immune protection of vaccination with each recombinant protein respectively in preventing systemic candidiasis in BALB/c mice was assessed. The injection of rPmt4p vaccination significantly increased survival rate, decreased fungal burdens in the heart, liver, brain, and kidneys, and increased serum levels of both immunoglobulin G (IgG) and IgM against rPmt4p in the immunized mice. Histopathological assessment demonstrated that rPmt4p vaccination protected the tissue structure, and decreased the infiltration of inflammatory cells. Passive transfer of the rPmt4p immunized serum increased survival rate against murine systemic candidiasis and significantly reduced organ fungal burden. The immune serum enhanced mouse neutrophil killing activity by directly neutralizing rPmt4p effects in vitro. Levels of interleukin (IL)-4, IL-10, IL-12p70, IL-17A and tumor necrosis factor (TNF)-α in serum were higher in the immunized mice compared to those in the adjuvant control group. In conclusion, our results suggested that rPmt4p vaccination may be considered as a potential vaccine candidate against systemic candidiasis.
Pharmacomechanical Thrombectomy in Paget–Schroetter Syndrome
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kärkkäinen, Jussi M., E-mail: jkarkkai@gmail.com; Nuutinen, Henrik; Riekkinen, Teemu
PurposeThe purpose of the study was to evaluate feasibility of pharmacomechanical thrombectomy (PMT) in the treatment of Paget–Schroetter syndrome (PSS) followed by thoracoscopic or open surgical decompression of the subclavian vein.MethodsTwenty-two out of 27 consecutive patients with PSS received PMT using the Trellis-8 peripheral infusion system (Covidien) between 2010 and 2014. Subsequent surgery was performed in 18 of those patients, 9 patients were treated with thoracoscopic, 7 patients with subclavicular, and 2 patients with transaxillary first rib resection, 4 patients were treated with PMT and anticoagulation alone. Technical success, complications, and patency were registered.ResultsPMT was successful in 21 (95 %) patients;more » 1 patient with unsatisfactory lysis received further catheter-directed thrombolysis, which, however, did not improve the result. The mean endovascular procedure time was 105 ± 33 min (range 70–200 min), and the required median amount of thrombolytic agent was 500,000 international unit (IU; range 250,000–1,000,000 IU). Adjunctive balloon venoplasty and aspiration were used in 18 (82 %) and 7 (32 %) cases, respectively. One patient had an intimal tear of the subclavian vein that was discovered and repaired during surgery. There were no other complications related to the endovascular procedure. At follow-up, 18 of 21 patients (86 %) with follow-up imaging available had patent subclavian vein, and all except 1 of the 22 patients were asymptomatic. The mean follow-up time was 25 ± 17 months.ConclusionsIn experienced hands, PMT is effective for early thrombus removal in PSS. Surgical decompression must be considered after PMT.« less
Fujise, Osamu; Miura, Mayumi; Hamachi, Takafumi; Maeda, Katsumasa
2006-08-01
Porphyromonas gingivalis is considered a critical pathogen of periodontal diseases including recurrent periodontitis. The profound effects of active periodontal treatment (APT) on P. gingivalis elimination were previously demonstrated and revealed that the subsequent P. gingivalis-free or -suppressed status seems to be maintained during early periodontal maintenance (PMT). The aim of the present study was to show the occurrence of microbial recolonization during this early PMT period. In total, 128 sites from 11 generalized chronic periodontitis patients and one generalized aggressive periodontitis patient underwent clinical and microbiologic examination at baseline (Exam-I), after APT (Exam-II), and in PMT (Exam-III). Exam-III was carried out an average of 4.5 +/- 3.5 months after Exam-II. Detection and quantification of putative pathogens were performed using a polymerase chain reaction-based method. The PMT used was effective in maintaining the clinical conditions improved by APT. However, in microbiological examinations, Exam-III showed higher detection frequency and levels of P. gingivalis than Exam-II. This suggests that a P. gingivalis recolonization started in the early PMT period. P. gingivalis-increased sites then showed significantly more severe signs of periodontitis in Exam-I than P. gingivalis-stable sites (bleeding on probing frequency: 76.7% versus 56.5%; suppuration frequency: 41.9% versus 12.9%). On the other hand, in Exam-II, no significant differences of clinical parameters were noted between P. gingivalis-increased and -stable sites. Severe periodontitis sites before APT seemed to place them at risk of P. gingivalis recolonization in the early PMT period, and this microbial restoration could be a cause of recurrent periodontitis.
Cui, Bin; Liao, Qiuyan; Lam, Wendy Wing Tak; Liu, Zong Ping; Fielding, Richard
2017-05-18
Poultry farmers are at high-risk from avian influenza A/H7N9 infection due to sustained occupational exposures to live poultry. This study examined factors associated with poultry farmers' adoption of personal protective behaviours (PPBs) based on Protection Motivation Theory (PMT). Totally, 297 poultry farmers in three cities of Jiangsu Province, China were interviewed during November 2013-January 2014. Data on PMT constructs, perceived trustworthiness of A/H7N9 information from mass media (formal sources), friends and family (informal sources), intention to adopt and actual adoption of PPBs and respondents' demographics were collected. Structural equation modeling (SEM) identified associations between demographic factors and PMT constructs associated with A/H7N9-oriented PPB intention. Moderated mediation analysis examined how demographics moderated the effects of information trust on PPB intention via risk perceptions of A/H7N9. Respondents generally perceived low vulnerability to A/H7N9 infection. The SEM found that male respondents perceived lower severity of (β = -0.23), and lower vulnerability to (β = -0.15) A/H7N9 infection; age was positively associated with both perceived personal vulnerability to (β = 0.21) and perceived self-efficacy (β = 0.24) in controlling A/H7N9; education was positively associated with perceived response efficacy (β = 0.40). Furthermore, perceived vulnerability (β = 0.16), perceived self-efficacy (β = 0.21) and response efficacy (β = 0.67) were positively associated with intention to adopt PPBs against A/H7N9. More trust in informal information (TII) was only significantly associated with greater PPB intention through its positive association with perceived response efficacy. Age significantly moderated the associations of TII with perceived Self-efficacy and perceived response efficacy, with younger farmers who had greater TII perceiving lower self-efficacy but higher response efficacy. Poultry farmers perceive A/H7N9 as a personally-irrelevant risk. Interventions designed to enhance perceived response efficacy, particularly among lower educated respondents may effectively motivate adoption of PPBs. Informal information may be an important resource for enhancing response efficacy.
Ko, Guen Bae; Lee, Jae Sung
2015-01-01
Metal package photomultiplier tubes (PMTs) with a metal channel dynode structure have several advanced features for devising such time-of-flight (TOF) and high spatial resolution positron emission tomography (PET) detectors, thanks to their high packing density, large effective area ratio, fast time response, and position encoding capability. Here, we report on an investigation of new metal package PMTs with high quantum efficiency (QE) for high-resolution PET and TOF PET detector modules. The latest metal package PMT, the Hamamatsu R11265 series, is served with two kinds of photocathodes that have higher quantum efficiency than normal bialkali (typical QE ≈ 25%), super bialkali (SBA; QE ≈ 35%), and ultra bialkali (UBA; QE ≈ 43%). In this study, the authors evaluated the performance of the new PMTs with SBA and UBA photocathodes as a PET detector by coupling various crystal arrays. They also investigated the performance improvements of high QE, focusing in particular on a block detector coupled with a lutetium-based scintillator. A single 4 × 4 × 10 mm(3) LYSO, a 7 × 7 array of 3 × 3 × 20 mm(3) LGSO, a 9 × 9 array of 1.2 × 1.2 × 10 mm(3) LYSO, and a 6 × 6 array of 1.5 × 1.5 × 7 mm(3) LuYAP were used for evaluation. All coincidence data were acquired with a DRS4 based fast digitizer. This new PMT shows promising crystal positioning accuracy, energy and time discrimination performance for TOF, and high-resolution PET applications. The authors also found that a metal channel PMT with SBA was enough for both TOF and high-resolution application, although UBA gave a minor improvement to time resolution. However, significant performance improvement was observed in relative low light output crystals (LuYAP) coupled with UBA. The results of this study will be of value as a useful reference to select PMTs for high-performance PET detectors.
Development of a high-sensitivity BGO well counter for small animal PET studies.
Yamamoto, Seiichi; Watabe, Hiroshi; Kanai, Yasukazu; Watabe, Tadashi; Imaizumi, Masao; Shimosegawa, Eku; Hatazawa, Jun
2012-01-01
In quantitative measurements of small animal PET studies, blood sampling is limited due to the small amounts of blood such animals can provide. In addition, injection doses are quite limited. In this situation, a high-sensitivity well counter would be useful for reducing the amount of the blood sample needed from small animals. Bismuth germinate (BGO) has a high stopping power for high-energy gamma rays compared to NaI(Tl), which is commonly used for conventional well counters. We have developed a BGO well counter and have tested it for blood-sampling measurements in small animals. The BGO well counter uses a square BGO block (59 × 59 × 50 mm) with a square open space (27 × 27 × 34 mm) in the center of the block. The BGO block was optically coupled to a 59-mm square-shaped photomultiplier tube (PMT). Signals from the PMT were digitally processed for the integration and energy window setting. The results showed that the energy spectrum of the BGO well counter measured with a Na-22 point source provided counts that were about 6 times higher for a 1022-keV (511 keV × 2) gamma peak than the spectrum of a 2-in. NaI(Tl) well counter. The relative sensitivity of the developed BGO well counter was 3.4 times higher than that of a NaI(Tl) well counter. The time activity curve of arterial blood was obtained successfully with the BGO well counter for a F-18-FDG study on rat. The BGO well counter will contribute to reducing the amount of sampled blood and to improving the throughput of quantitative measurements in small animal PET studies.
NASA Astrophysics Data System (ADS)
Kim, Dong-Won; Sivakkumar, S. R.; MacFarlane, Douglas R.; Forsyth, Maria; Sun, Yang-Kook
A poly(3-methylthiophene) (PMT)/multi-walled carbon nanotube (CNT) composite is synthesized by in situ chemical polymerization. The PMT/CNT composite is used as an active cathode material in lithium metal polymer cells assembled with ionic liquid (IL) electrolytes. The IL electrolyte consists of 1-ethyl-3-methylimidazolium tetrafluoroborate (EMIBF 4) and LiBF 4. A small amount of vinylene carbonate is added to the IL electrolyte to prevent the reductive decomposition of the imidazolium cation in EMIBF 4. A porous poly(vinylidene fluoride- co-hexafluoropropylene) (P(VdF- co-HFP)) film is used as a polymer membrane for assembling the cells. Electrochemical properties of the PMT/CNT composite electrode in the IL electrolyte are evaluated and the effect of vinylene carbonate on the cycling performance of the lithium metal polymer cells is investigated. The cells assembled with a non-flammable IL electrolyte and a PMT/CNT composite cathode are promising candidates for high-voltage-power sources with enhanced safety.
Gaston, Anca; Prapavessis, Harry
2014-04-01
Despite the benefits of exercise during pregnancy, many expectant mothers are inactive. This study examined whether augmenting a protection motivation theory (PMT) intervention with a Health Action Process Approach can enhance exercise behavior change among pregnant women. Sixty inactive pregnant women were randomly assigned to one of three treatment groups: PMT-only, PMT + action-planning, and PMT + action-and-coping-planning. Week-long objective (accelerometer) and subjective (self-report) exercise measures were collected at baseline, and at 1- and 4-weeks post-intervention. Repeated-measures ANOVAs demonstrated that while all participants reported increased exercise from baseline to 1-week post-intervention, participants in both planning groups were significantly more active (p < .001) than those in the PMT-only group by 4-weeks post-intervention (η (2) = .13 and .15 for accelerometer and self-report data, respectively). In conclusion, augmenting a PMT intervention with action or action-and-coping-planning can enhance exercise behavior change in pregnant women.
Optimization of a LSO-Based Detector Module for Time-of-Flight PET
NASA Astrophysics Data System (ADS)
Moses, W. W.; Janecek, M.; Spurrier, M. A.; Szupryczynski, P.; Choong, W.-S.; Melcher, C. L.; Andreaco, M.
2010-06-01
We have explored methods for optimizing the timing resolution of an LSO-based detector module for a single-ring, “demonstration” time-of-flight PET camera. By maximizing the area that couples the scintillator to the PMT and minimizing the average path length that the scintillation photons travel, a single detector timing resolution of 218 ps fwhm is measured, which is considerably better than the 385 ps fwhm obtained by commercial LSO or LYSO TOF detector modules. We explored different surface treatments (saw-cut, mechanically polished, and chemically etched) and reflector materials (Teflon tape, ESR, Lumirror, Melinex, white epoxy, and white paint), and found that for our geometry, a chemically etched surface had 5% better timing resolution than the saw-cut or mechanically polished surfaces, and while there was little dependence on the timing resolution between the various reflectors, white paint and white epoxy were a few percent better. Adding co-dopants to LSO shortened the decay time from 40 ns to 30 ns but maintained the same or higher total light output. This increased the initial photoelectron rate and so improved the timing resolution by 15%. Using photomultiplier tubes with higher quantum efficiency (blue sensitivity index of 13.5 rather than 12) improved the timing resolution by an additional 5%. By choosing the optimum surface treatment (chemically etched), reflector (white paint), LSO composition (co-doped), and PMT (13.5 blue sensitivity index), the coincidence timing resolution of our detector module was reduced from 309 ps to 220 ps fwhm.
Fitting PMT Responses with an Artificial Neural Network
NASA Astrophysics Data System (ADS)
Kemmerer, William; Niculescu, Gabriel
2017-09-01
Correctly modeling the low light responce of photodetectors such as photomultiplier tubes (PMT) is crucial for the operation of particle detection relying on the Cherenkov effect. The Gas Ring Imaging Cherenkov (GRINCH) in the SuperBigBite Spectrometer (SBS) at Jefferson Lab will rely on an array of 510 29 mm 9125B PMTs. To select the tubes for this array, more than 900 were tested and their low-light response function was fitted. An Artificial Neural Network was defined and trained to extract the relevant PMT parameters without carrying out a detailed fir of the ADC spectrum. These results will be discussed here. NSF.
Wang, Zhi-Kang; Cai, Qing; Liu, Jin; Ying, Sheng-Hua; Feng, Ming-Guang
2017-01-01
Lysine acetylation (Kac) events in filamentous fungi are poorly explored. Here we show a lysine acetylome generated by LC-MS/MS analysis of immunoaffinity-based Kac peptides from normal hyphal cells of Beauveria bassiana, a fungal entomopathogen. The acetylome comprised 283 Kac proteins and 464 Kac sites. These proteins were enriched to eight molecular functions, 20 cellular components, 27 biological processes, 20 KEGG pathways and 12 subcellular localizations. All Kac sites were characterized as six Kac motifs, including a novel motif (KacW) for 26 Kac sites of 17 unknown proteins. Many Kac sites were predicted to be multifunctional, largely expanding the fungal Kac events. Biological importance of identified Kac sites was confirmed through functional analysis of Kac sites on Pmt1 and Pmt4, two O-mannosyltransferases. Singular site mutations (K88R and K482R) of Pmt1 resulted in impaired conidiation, attenuated virulence and decreased tolerance to oxidation and cell wall perturbation. These defects were close to or more severe than those caused by the deletion of pmt1. The Pmt4 K360R mutation facilitated colony growth under normal and stressful conditions and enhanced the fungal virulence. Our findings provide the first insight into the Kac events of B. bassiana and their links to the fungal potential against insect pests. PMID:28295016
Williams, Lynn; Rasmussen, Susan; Kleczkowski, Adam; Maharaj, Savi; Cairns, Nicole
2015-01-01
Epidemics of respiratory infectious disease remain one of the most serious health risks facing the population. Non-pharmaceutical interventions (e.g. hand-washing or wearing face masks) can have a significant impact on the course of an infectious disease epidemic. The current study investigated whether protection motivation theory (PMT) is a useful framework for understanding social distancing behaviour (i.e. the tendency to reduce social contacts) in response to a simulated infectious disease epidemic. There were 230 participants (109 males, 121 females, mean age 32.4 years) from the general population who completed self-report measures assessing the components of PMT. In addition, participants completed a computer game which simulated an infectious disease epidemic in order to provide a measure of social distancing behaviour. The regression analyses revealed that none of the PMT variables were significant predictors of social distancing behaviour during the simulation task. However, fear (β = .218, p < .001), response efficacy (β = .175, p < .01) and self-efficacy (β = .251, p < .001) were all significant predictors of intention to engage in social distancing behaviour. Overall, the PMT variables (and demographic factors) explain 21.2% of the variance in intention. The findings demonstrated that PMT was a useful framework for understanding intention to engage in social distancing behaviour, but not actual behaviour during the simulated epidemic. These findings may reflect an intention-behaviour gap in relation to social distancing behaviour.
Improving Warehouse Inventory Management Through Rfid, Barcoding and Robotics Technologies
2014-12-01
as a spider merge. This was designed and installed to speed up the conveyors . In their original design , conveyors traveled throughout the warehouse...lifts LCL lower confidence level xiv MRO material release order NPV net present value PMT positive material transfer POM Program Objective...depots. Active Radio Frequency Identification (aRFID ) Migration A program designed to move the active RFID enterprise from a proprietarily air interface
Increasing Communication in Children with Concurrent Vision and Hearing Loss
ERIC Educational Resources Information Center
Brady, Nancy C.; Bashinski, Susan M.
2008-01-01
Nine children with complex communication needs and concurrent vision and hearing losses participated in an intervention program aimed at increasing intentional prelinguistic communication. The intervention constituted a pilot, descriptive study of an adapted version of prelinguistic milieu teaching, hence referred to as A-PMT. In A-PMT, natural…
Janczarek, Monika; Palusińska-Szysz, Marta
2016-05-01
Legionella bacteria are organisms of public health interest due to their ability to cause pneumonia (Legionnaires' disease) in susceptible humans and their ubiquitous presence in water supply systems. Rapid diagnosis of Legionnaires' disease allows the use of therapy specific for the disease. L. pneumophila serogroup 1 is the most common cause of infection acquired in community and hospital environments. The non-L. pneumophila infections are likely under-detected because of a lack of effective diagnosis. In this work, simplex and duplex PCR assays with the use of new molecular markers pcs and pmtA involved in phosphatidylcholine synthesis were specified for rapid and cost-efficient identification and distinguishing Legionella species. The sets of primers developed were found to be sensitive and specific for reliable detection of Legionella belonging to the eight most clinically relevant species. Among these, four primer sets I, II, VI, and VII used for duplex-PCRs proved to have the highest identification power and reliability in the detection of the bacteria. Application of this PCR-based method should improve detection of Legionella spp. in both clinical and environmental settings and facilitate molecular typing of these organisms.
Development of a fluorimeter using laser-induced single-shot fluorescence lifetime spectroscopy
NASA Astrophysics Data System (ADS)
Eisum, Niels H.; Lynggaard-Jensen, Anders
1990-08-01
The developed laboratory prototype fluorimeter is the first step to a new in-situ instrument, and is based on a pulsed nitrogen laser (pumping a color dye laser and the laserbeam passing through a frequency doubler) with a pulse width less than 1 nsec. With such a short excitation pulse it is possible to measure the exponential decay of the fluorescence from the aromatic compounds and thus determine the fluorescence lifetime-curves, which are typically in the region of 5-40 nsec. The emitted fluorescence is collected simultaneously in 35 channels in the wavelength region 250-600 nm. If the fluorescence falls within the transmission areas of the interference filters in each channel the light will be collected by a plastic light guide (doped PMMA) in the actual channel and transmitted to the channels photo multiplier tube (PMT). (The use of the plastic light guide improves the sensitivity). The signal from the PMT is passed on to a 200 MHz 8-bit flash AID-converter connected to a local memory. From this local memory the digital lifetime curves from each channel are transmitted to a computer for presentation of the 3-dimensional spectrum. This spectrum has been obtained with a single laser shot.
CT and MR imaging features in phosphaturic mesenchymal tumor-mixed connective tissue: A case report
Shi, Zhenshan; Deng, Yiqiong; Li, Xiumei; Li, Yueming; Cao, Dairong; Coossa, Vikash Sahadeo
2018-01-01
Phosphaturic mesenchymal tumor-mixed connective tissue (PMT-MCT) is rare and usually benign and slow-growing. The majority of these tumors is associated with sporadic tumor-induced osteomalacia (TIO) or rickets, affect middle-aged individuals and are located in the extremities. Previous imaging studies often focused on seeking the causative tumors of TIO, not on the radiological features of these tumors, especially magnetic resonance imaging (MRI) features. PMT-MCT remains a largely misdiagnosed, ignored or unknown entity by most radiologists and clinicians. In the present case report, a review of the known literature of PMT-MCT was conducted and the CT and MRI findings from three patient cases were described for diagnosing the small subcutaneous tumor. Typical MRI appearances of PMT-MCT were isointense relative to the muscles on T1-weighted imaging, and markedly hyperintense on T2-weighted imaging containing variably flow voids, with markedly heterogeneous/homogenous enhancement on post contrast T1-weighted fat-suppression imaging. Short time inversion recovery was demonstrated to be the optimal sequence in localizing the tumor. PMID:29552133
CT and MR imaging features in phosphaturic mesenchymal tumor-mixed connective tissue: A case report.
Shi, Zhenshan; Deng, Yiqiong; Li, Xiumei; Li, Yueming; Cao, Dairong; Coossa, Vikash Sahadeo
2018-04-01
Phosphaturic mesenchymal tumor-mixed connective tissue (PMT-MCT) is rare and usually benign and slow-growing. The majority of these tumors is associated with sporadic tumor-induced osteomalacia (TIO) or rickets, affect middle-aged individuals and are located in the extremities. Previous imaging studies often focused on seeking the causative tumors of TIO, not on the radiological features of these tumors, especially magnetic resonance imaging (MRI) features. PMT-MCT remains a largely misdiagnosed, ignored or unknown entity by most radiologists and clinicians. In the present case report, a review of the known literature of PMT-MCT was conducted and the CT and MRI findings from three patient cases were described for diagnosing the small subcutaneous tumor. Typical MRI appearances of PMT-MCT were isointense relative to the muscles on T1-weighted imaging, and markedly hyperintense on T2-weighted imaging containing variably flow voids, with markedly heterogeneous/homogenous enhancement on post contrast T1-weighted fat-suppression imaging. Short time inversion recovery was demonstrated to be the optimal sequence in localizing the tumor.
Dehdari, T; Hassani, L; Shojaeizadeh, D; Hajizadeh, E; Nedjat, S; Abedini, M
2016-01-01
Given the importance of papanicolaou (Pap) test in the early detection and timely treatment of cervical cancer, present study was designed to determine predictors of a sample of Iranian women's intention to first Pap test practice based on the protection motivation theory (PMT) variables. In this cross-sectional study, a total of 240 women referral to the 30 primary health care clinics were selected. They completed a developed scale based on PMT variables including intention, perceived vulnerability and severity, fear, response costs, response efficacy and self-efficacy. Path analysis was used to determine the association between predictive factors and intention. The results showed that PMT had goodness of fit with a χ2/df = 2.37, df = 28, P= 0.001 and RMSEA = 0.076. PMT explained 42% of the variance in women's intention to get first Pap smear test. Self-efficacy (b = 0.55, P< 0.001) and response efficacy (b = 0.19, P< 0.001) were found to be the predictors of intention. These findings may be used to develop tailored, theory-based educational interventions associated with Pap testing among women.
Bucsenez, M; Rüping, B; Behrens, S; Twyman, R M; Noll, G A; Prüfer, D
2012-09-01
The sieve element occlusion (SEO) gene family includes several members that are expressed specifically in immature sieve elements (SEs) in the developing phloem of dicotyledonous plants. To determine how this restricted expression profile is achieved, we analysed the SE-specific Medicago truncatula SEO-F1 promoter (PMtSEO-F1) by constructing deletion, substitution and hybrid constructs and testing them in transgenic tobacco plants using green fluorescent protein as a reporter. This revealed four promoter regions, each containing cis-regulatory elements that activate transcription in SEs. One of these segments also contained sufficient information to suppress PMtSEO-F1 transcription in the phloem companion cells (CCs). Subsequent in silico analysis revealed several candidate cis-regulatory elements that PMtSEO-F1 shares with other SEO promoters. These putative sieve element boxes (PSE boxes) are promising candidates for cis-regulatory elements controlling the SE-specific expression of PMtSEO-F1. © 2012 German Botanical Society and The Royal Botanical Society of the Netherlands.
Characterizing ICF Neutron Scintillation Diagnostics on the nTOF line at SUNY Geneseo
NASA Astrophysics Data System (ADS)
Lawson-Keister, Pat; Padawar-Curry, Jonah; Visca, Hannah; Fletcher, Kurt; Padalino, Stephen; Sangster, T. Craig; Regan, Sean
2015-11-01
Neutron scintillator diagnostics for ICF and HEDP can be characterized using the neutron time-of-flight (nTOF) line on Geneseo's 1.7 MV tandem Pelletron accelerator. Neutron signals can be differentiated from gamma signals by employing coincidence methods. A 1.8-MeV beam of deuterons incident on a deuterated polyethylene target produces neutrons via the 2H(d,n)3He reaction. Neutrons emerging at a lab angle of 88° have an energy of 2.96 MeV; the 3He ions associated with these neutrons are detected at a scattering angle of 43° using a surface barrier detector. The time of flight of the neutron can be measured by using the 3He detection as a ``start'' signal and the scintillation detection as a ``stop'' signal. This time of flight requirement is used to identify the 2.96-MeV neutron signals in the scintillator. To measure the light curve produced by these monoenergetic neutrons, two photomultiplier (PMT) tubes are attached to the scintillator. The full aperture PMT establishes the nTOF coincidence. The other PMT is fitted with a pinhole to collect single events. The time between the full aperture PMT signal and the arrival of the signal in the pinhole PMT is used to determine the light curve for the scintillator. This system will enable the neutron response of various scintillators to be compared. Supported in part by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944.
Babazadeh, Towhid; Nadrian, Haidar; Banayejeddi, Morteza; Rezapour, Baratali
2017-09-01
Skin cancer is one of the most prevalent cancers, worldwide, which happens more among those with more sunlight exposure like farmers. The aim of this study was to explore the determinants of skin cancer preventive behaviors (SCPBs) among rural farmers using Protection Motivation Theory (PMT). In this cross-sectional study, multistage random sampling was employed to enroll 238 farmers referring to rural health houses (HH) in Chaldoran County, Iran. A valid and reliable instrument based on PMT variables was used. Significant correlations were found between all PMT variables with SCPBs (p < 0.05). Hierarchical multiple linear regressions were performed with Protection Motivation and SCPBs as outcome variables. Predictors for these two outcome variables were classified in two different blocks according to their natures. Demographic characteristics (p > 0.05) and PMT constructs (p < 0.001) explained 3 and 63.6 % of the observed variance in Protection Motivation, respectively. Also, no significant effect was found on SCPBs by demographic variables, in the first block (∆R 2 = 0.025); however, in the second block, Perceived Susceptibility (p = 0.000), Rewards (p = 0.022), Self-efficacy (p = 0.000), and Response Cost (p = 0.001) were significant predictors of SCPBs (∆R 2 = 0.432). Health care providers may consider PMT as a framework for developing educational interventions aiming at improving SCPBs among rural farmers.
Högström, Jens; Enebrink, Pia; Ghaderi, Ata
2013-04-01
Although parent management training (PMT) is generally considered the treatment of choice for children with conduct problems, some specific adaptations might be essential for various subgroups of parents or children to benefit well from PMT. The aim of this study was to examine the influence of child callous-unemotional (CU) traits on the outcome of an Internet-based PMT program for parents of children with conduct problems (n = 57; mean age 6.65). Within a randomized controlled trial of PMT, children assigned to the intervention group were categorized and compared as either "high-CU" (n = 8) or "low-CU" (n = 49) based on a cut-off score on the CU subscale of the Antisocial Process Screening Device (APSD; Frick & Hare, 2001). CU traits in children were associated with more severe conduct problems at baseline, as well as more hyperactivity and peer-related problems. Treatment outcome, in terms of conduct-problem reduction, was poor in the high-CU group compared with the low-CU group, despite the fact that parents in both groups improved equally in parenting skills. The same pattern of results emerged after controlling for initial difficulties of conduct problems and other pretreatment differences between the groups. Elevated levels of CU traits in children seem to contribute to an inferior treatment response in PMT. These findings call for more attention on empathy and emotional patterns in the assessment of children with conduct problems. (PsycINFO Database Record (c) 2013 APA, all rights reserved).
Saen-oon, Suwipa; Lee, Soon Goo; Jez, Joseph M.; Guallar, Victor
2014-01-01
The phosphobase methylation pathway catalyzed by the phosphoethanolamine methyltransferase in Plasmodium falciparum (PfPMT), the malaria parasite, offers an attractive target for anti-parasitic drug development. PfPMT methylates phosphoethanolamine (pEA) to phosphocholine for use in membrane biogenesis. Quantum mechanics and molecular mechanics (QM/MM) calculations tested the proposed reaction mechanism for methylation of pEA involving the previously identified Tyr-19–His-132 dyad, which indicated an energetically unfavorable mechanism. Instead, the QM/MM calculations suggested an alternative mechanism involving Asp-128. The reaction coordinate involves the stepwise transfer of a proton to Asp-128 via a bridging water molecule followed by a typical Sn2-type methyl transfer from S-adenosylmethionine to pEA. Functional analysis of the D128A, D128E, D128Q, and D128N PfPMT mutants shows a loss of activity with pEA but not with the final substrate of the methylation pathway. X-ray crystal structures of the PfPMT-D128A mutant in complex with S-adenosylhomocysteine and either pEA or phosphocholine reveal how mutation of Asp-128 disrupts a hydrogen bond network in the active site. The combined QM/MM, biochemical, and structural studies identify a key role for Asp-128 in the initial step of the phosphobase methylation pathway in Plasmodium and provide molecular insight on the evolution of multiple activities in the active site of the PMT. PMID:25288796
Saen-oon, Suwipa; Lee, Soon Goo; Jez, Joseph M.; ...
2014-10-06
Here, the phosphobase methylation pathway catalyzed by the phosphoethanolamine methyltransferase in Plasmodium falciparum (PfPMT), the malaria parasite, offers an attractive target for anti-parasitic drug development. PfPMT methylates phosphoethanolamine (pEA) to phosphocholine for use in membrane biogenesis. Quantum mechanics and molecular mechanics (QM/MM) calculations tested the proposed reaction mechanism for methylation of pEA involving the previously identified Tyr-19–His-132 dyad, which indicated an energetically unfavorable mechanism. Instead, the QM/MM calculations suggested an alternative mechanism involving Asp-128. The reaction coordinate involves the stepwise transfer of a proton to Asp-128 via a bridging water molecule followed by a typical S n2-type methyl transfer frommore » S-adenosylmethionine to pEA. Functional analysis of the D128A, D128E, D128Q, and D128N PfPMT mutants shows a loss of activity with pEA but not with the final substrate of the methylation pathway. X-ray crystal structures of the PfPMT-D128A mutant in complex with S-adenosylhomocysteine and either pEA or phosphocholine reveal how mutation of Asp-128 disrupts a hydrogen bond network in the active site. The combined QM/MM, biochemical, and structural studies identify a key role for Asp-128 in the initial step of the phosphobase methylation pathway in Plasmodium and provide molecular insight on the evolution of multiple activities in the active site of the PMT.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saen-oon, Suwipa; Lee, Soon Goo; Jez, Joseph M.
Here, the phosphobase methylation pathway catalyzed by the phosphoethanolamine methyltransferase in Plasmodium falciparum (PfPMT), the malaria parasite, offers an attractive target for anti-parasitic drug development. PfPMT methylates phosphoethanolamine (pEA) to phosphocholine for use in membrane biogenesis. Quantum mechanics and molecular mechanics (QM/MM) calculations tested the proposed reaction mechanism for methylation of pEA involving the previously identified Tyr-19–His-132 dyad, which indicated an energetically unfavorable mechanism. Instead, the QM/MM calculations suggested an alternative mechanism involving Asp-128. The reaction coordinate involves the stepwise transfer of a proton to Asp-128 via a bridging water molecule followed by a typical S n2-type methyl transfer frommore » S-adenosylmethionine to pEA. Functional analysis of the D128A, D128E, D128Q, and D128N PfPMT mutants shows a loss of activity with pEA but not with the final substrate of the methylation pathway. X-ray crystal structures of the PfPMT-D128A mutant in complex with S-adenosylhomocysteine and either pEA or phosphocholine reveal how mutation of Asp-128 disrupts a hydrogen bond network in the active site. The combined QM/MM, biochemical, and structural studies identify a key role for Asp-128 in the initial step of the phosphobase methylation pathway in Plasmodium and provide molecular insight on the evolution of multiple activities in the active site of the PMT.« less
Bannai, Yuka; Aminova, Leila R.; Faulkner, Melinda J.; Ho, Mengfei; Wilson, Brenda A.
2012-01-01
The dermonecrotic toxins from Pasteurella multocida (PMT), Bordetella (DNT), Escherichia coli (CNF1-3), and Yersinia (CNFY) modulate their G-protein targets through deamidation and/or transglutamination of an active site Gln residue, which results in activation of the G protein and its cognate downstream signaling pathways. Whereas DNT and the CNFs act on small Rho GTPases, PMT acts on the α subunit of heterotrimeric Gq, Gi, and G12/13 proteins. We previously demonstrated that PMT potently blocks adipogenesis and adipocyte differentiation in a calcineurin-independent manner through downregulation of Notch1 and stabilization of β-catenin and Pref1/Dlk1, key proteins in signaling pathways strongly linked to cell fate decisions, including fat and bone development. Here, we report that similar to PMT, DNT, and CNF1 completely block adipogenesis and adipocyte differentiation by preventing upregulation of adipocyte markers, PPARγ and C/EBPα, while stabilizing the expression of Pref1/Dlk1 and β-catenin. We show that the Rho/ROCK inhibitor Y-27632 prevented or reversed these toxin-mediated effects, strongly supporting a role for Rho/ROCK signaling in dermonecrotic toxin-mediated inhibition of adipogenesis and adipocyte differentiation. Toxin treatment was also accompanied by downregulation of Notch1 expression, although this inhibition was independent of Rho/ROCK signaling. We further show that PMT-mediated downregulation of Notch1 expression occurs primarily through G12/13 signaling. Our results reveal new details of the pathways involved in dermonecrotic toxin action on adipocyte differentiation, and the role of Rho/ROCK signaling in mediating toxin effects on Wnt/β-catenin and Notch1 signaling, and in particular the role of Gq and G12/13 in mediating PMT effects on Rho/ROCK and Notch1 signaling. PMID:22919671
The pipe model theory half a century on: a review.
Lehnebach, Romain; Beyer, Robert; Letort, Véronique; Heuret, Patrick
2018-01-23
More than a half century ago, Shinozaki et al. (Shinozaki K, Yoda K, Hozumi K, Kira T. 1964b. A quantitative analysis of plant form - the pipe model theory. II. Further evidence of the theory and its application in forest ecology. Japanese Journal of Ecology14: 133-139) proposed an elegant conceptual framework, the pipe model theory (PMT), to interpret the observed linear relationship between the amount of stem tissue and corresponding supported leaves. The PMT brought a satisfactory answer to two vividly debated problems that were unresolved at the moment of its publication: (1) What determines tree form and which rules drive biomass allocation to the foliar versus stem compartments in plants? (2) How can foliar area or mass in an individual plant, in a stand or at even larger scales be estimated? Since its initial formulation, the PMT has been reinterpreted and used in applications, and has undoubtedly become an important milestone in the mathematical interpretation of plant form and functioning. This article aims to review the PMT by going back to its initial formulation, stating its explicit and implicit properties and discussing them in the light of current biological knowledge and experimental evidence in order to identify the validity and range of applicability of the theory. We also discuss the use of the theory in tree biomechanics and hydraulics as well as in functional-structural plant modelling. Scrutinizing the PMT in the light of modern biological knowledge revealed that most of its properties are not valid as a general rule. The hydraulic framework derived from the PMT has attracted much more attention than its mechanical counterpart and implies that only the conductive portion of a stem cross-section should be proportional to the supported foliage amount rather than the whole of it. The facts that this conductive portion is experimentally difficult to measure and varies with environmental conditions and tree ontogeny might cause the commonly reported non-linear relationships between foliage and stem metrics. Nevertheless, the PMT can still be considered as a portfolio of properties providing a unified framework to integrate and analyse functional-structural relationships. © The Author(s) 2018. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Hager, Eric; Yuo, Theodore; Avgerinos, Efthymios; Naddaf, Abdullah; Jeyabalan, Geetha; Marone, Luke; Chaer, Rabih
2014-07-01
Pharmacomechanical thrombolysis (PMT) and catheter-directed thrombolysis (CDT) are commonly used for the treatment of iliofemoral deep venous thrombosis (DVT). The purpose of this study was to examine the short- and long-term venous patency and venous valvular function as well as clinical outcomes of patients treated for iliofemoral DVT by PMT and CDT. A retrospective review of all patients with symptomatic DVT treated between 2006 and 2011 with PMT or CDT was performed. All patients were treated by local tissue plasminogen activator delivered with PMT or CDT. Patients were divided into two groups on the basis of initial treatment modality: patients treated by PMT alone (group 1), and those who underwent PMT and CDT or CDT alone (group 2). Group comorbidities, initial presenting symptoms, and Clinical, Etiologic, Anatomic, and Pathologic (CEAP) classification scores were compared. Postprocedural duplex ultrasound was used to assess valve function and treated vein patency rates. At all visits, Villalta and CEAP scores were recorded and compared. Group demographic and procedural results were analyzed by Fisher exact test for dichotomous variables and Kruskal-Wallis equality-of-populations rank test for the ordinal and continuous data. Kaplan-Meier survival estimates were used to assess preserved valve function as well as primary and secondary patency rates. There were 79 patients with 102 limbs treated for extensive iliofemoral DVT (median age, 51.5 years; range, 16.6-83.8 years). There were 18 patients in group 1 and 61 patients in group 2 (PMT + CDT [n = 54] or CDT alone [n = 7]). There were no differences in demographics or comorbidities between groups aside from malignant disease, which was more common in group 1 (35.3% vs 11.5%; P = .03). A total of 102 limbs were analyzed, 24 in group 1 and 78 in group 2. Patients in group 1 had a shorter symptom duration compared with group 2 (7 days vs 16 days; P = .011). The median number of procedures in group 1 was lower than in group 2 (P < .001). At last clinical follow-up, there was no significant difference between the Villalta and CEAP scores or the rate of clinical improvement in symptoms between groups. By Kaplan-Meier analysis, there was no difference in primary patency, secondary patency, and treated valve function at 48 months. This study suggests that PMT as a stand-alone therapy is as effective as CDT with or without PMT in preserving valve function and preventing postthrombotic syndrome. Long-term physiologic and functional outcomes are comparable between the modalities, with preserved venous valve function in the majority of patients. Copyright © 2014 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Psychosocial Correlates of HIV Protection Motivation among Black Adolescents in Venda, South Africa
ERIC Educational Resources Information Center
Boer, Henk; Mashamba, M. Tshilidzi
2005-01-01
We assessed the usefulness of the theory of planned behavior (TPB) and protection motivation theory (PMT) to predict intended condom use among 201 adolescents from Venda, South Africa. Results indicated that both the TPB and the PMT could significantly predict intended condom use, although the level of explained variance was limited. Hierarchical…
ERIC Educational Resources Information Center
Bolkan, San; Goodboy, Alan K.
2016-01-01
Protection motivation theory (PMT) explains people's adaptive behavior in response to personal threats. In this study, PMT was used to predict rhetorical dissent episodes related to 210 student reports of perceived classroom problems. In line with theoretical predictions, a moderated moderation analysis revealed that students were likely to voice…
Preparation of Three-Dimensional Graphene Foams Using Powder Metallurgy Templates.
Sha, Junwei; Gao, Caitian; Lee, Seoung-Ki; Li, Yilun; Zhao, Naiqin; Tour, James M
2016-01-26
A simple and scalable method which combines traditional powder metallurgy and chemical vapor deposition is developed for the synthesis of mesoporous free-standing 3D graphene foams. The powder metallurgy templates for 3D graphene foams (PMT-GFs) consist of particle-like carbon shells which are connected by multilayered graphene that shows high specific surface area (1080 m(2) g(-1)), good crystallization, good electrical conductivity (13.8 S cm(-1)), and a mechanically robust structure. The PMT-GFs did not break under direct flushing with DI water, and they were able to recover after being compressed. These properties indicate promising applications of PMT-GFs for fields requiring 3D carbon frameworks such as in energy-based electrodes and mechanical dampening.
A New Method for Reduction of Photomultiplier Signal-Induced Noise
NASA Technical Reports Server (NTRS)
Koble, Andrea; DeYoung, Russell
2000-01-01
For lidar measurements of ozone, photomultiplier tube (PMT) detector signal-induced noise represents a fundamental problem that complicates the extraction of information from lidar data. A new method is developed to significantly reduce signal-induced noise in lidar receiver PMT detectors. The electron optics of the lidar photomultiplier detector is modified to filter the source of signal-induced noise. A mesh electrode external to the PMT is utilized to control photoemission and disorient electron trajectories from the photocathode to the first dynode. Experiments were taken both with simulated and actual lidar return signals at Langley Research Center. Results show at least 40 percent more accurate ozone number density values with a mesh voltage of 60 V applied than with no voltage applied.
Aryeetey, Genevieve Cecilia; Jehu-Appiah, Caroline; Spaan, Ernst; D'Exelle, Ben; Agyepong, Irene; Baltussen, Rob
2010-12-01
To evaluate the effectiveness of three alternative strategies to identify poor households: means testing (MT), proxy means testing (PMT) and participatory wealth ranking (PWR) in urban, rural and semi-urban settings in Ghana. The primary motivation was to inform implementation of the National Health Insurance policy of premium exemptions for the poorest households. Survey of 145-147 households per setting to collect data on consumption expenditure to estimate MT measures and of household assets to estimate PMT measures. We organized focus group discussions to derive PWR measures. We compared errors of inclusion and exclusion of PMT and PWR relative to MT, the latter being considered the gold standard measure to identify poor households. Compared to MT, the errors of exclusion and inclusion of PMT ranged between 0.46-0.63 and 0.21-0.36, respectively, and of PWR between 0.03-0.73 and 0.17-0.60, respectively, depending on the setting. Proxy means testing and PWR have considerable errors of exclusion and inclusion in comparison with MT. PWR is a subjective measure of poverty and has appeal because it reflects community's perceptions on poverty. However, as its definition of the poor varies across settings, its acceptability as a uniform strategy to identify the poor in Ghana may be questionable. PMT and MT are potential strategies to identify the poor, and their relative societal attractiveness should be judged in a broader economic analysis. This study also holds relevance to other programmes that require identification of the poor in low-income countries. © 2010 Blackwell Publishing Ltd.
Macgregor, Lewis J; Ditroilo, Massimiliano; Smith, Iain J; Fairweather, Malcolm M; Hunter, Angus M
2016-08-01
Assessments of skeletal-muscle functional capacity often necessitate maximal contractile effort, which exacerbates muscle fatigue or injury. Tensiomyography (TMG) has been investigated as a means to assess muscle contractile function after fatigue; however, observations have not been contextualized by concurrent physiological measures. To measure peripheral-fatigue-induced alterations in mechanical and contractile properties of the plantar-flexor muscles through noninvasive TMG concurrently with maximal voluntary contraction (MVC) and passive muscle tension (PMT) to validate TMG as a gauge of peripheral fatigue. Pre- and posttest intervention with control. University laboratory. 21 healthy male volunteers. Subjects' plantar flexors were tested for TMG parameters, along with MVC and PMT, before and after either a 5-min rest period (control) or a 5-min electrical-stimulation intervention (fatigue). Temporal (contraction velocity) and spatial (radial displacement) contractile parameters of the gastrocnemius medialis were recorded through TMG. MVC was measured as an indicator of muscle fatigue, and PMT was measured to assess muscle stiffness. Radial displacement demonstrated a fatigue-associated reduction (3.3 ± 1.2 vs 4.0 ± 1.4 mm, P = .031), while contraction velocity remained unaltered. In addition, MVC significantly declined by 122.6 ± 104 N (P < .001) after stimulation (fatigue). PMT was significantly increased after fatigue (139.8 ± 54.3 vs 111.3 ± 44.6 N, P = .007). TMG successfully detected fatigue, evident from reduced MVC, by displaying impaired muscle displacement accompanied by elevated PMT. TMG could be useful in establishing skeletal-muscle fatigue status without exacerbating the functional decrement of the muscle.
ERIC Educational Resources Information Center
Peters, Sarah; Calam, Rachel; Harrington, Richard
2005-01-01
Background: The effectiveness of parent management training (PMT) as a treatment for child behaviour problems is reduced by high attrition rates. One difficulty with engaging mothers is that, by definition, PMT is directed at the parent, yet many parents believe the "cause" of the problem lies within the child. Hence the model of therapy offered…
UV Observations of Atomic Oxygen in the Cusp Region
NASA Astrophysics Data System (ADS)
Fritz, B.; Lessard, M.; Dymond, K.; Kenward, D. R.; Lynch, K. A.; Clemmons, J. H.; Hecht, J. H.; Hysell, D. L.; Crowley, G.
2017-12-01
The Rocket Experiment for Neutral Upwelling (RENU) 2 launched into the dayside cusp on 13 December, 2015. The sounding rocket payload carried a comprehensive suite of particle, field, and remote sensing instruments to characterize the thermosphere in a region where pockets of enhanced neutral density have been detected [Lühr et al, 2004]. An ultraviolet photomultiplier tube (UV PMT) was oriented to look along the magnetic field line and remotely detect neutral atomic oxygen (OI) above the payload. The UV PMT measured a clear enhancement as the payload descended through a poleward moving auroral form, an indicator of structure in both altitude and latitude. Context for the UV PMT measurement is provided by the Special Sensor Ultraviolet Imager (SSULI) instrument on the Defense Meteorological Space Program (DMSP) satellite, which also measured OI as it passed through the cusp. UV tomography of SSULI observations produces a two-dimensional cross-section of volumetric emission rates in the high-latitude thermosphere prior to the RENU 2 flight. The volume emission rate may then be inverted to produce a profile of neutral density in the thermosphere. A similar technique is used to interpret the UV PMT measurement and determine structure in the thermosphere as RENU 2 descended through the cusp.
Adolescents' protection motivation and smoking behaviour.
Thrul, Johannes; Stemmler, Mark; Bühler, Anneke; Kuntsche, Emmanuel
2013-08-01
The protection motivation theory (PMT) is a well-known theory of behaviour change. This study tested the applicability of the sub-constructs of threat and coping appraisal in predicting adolescents' smoking-related behavioural intentions and smoking behaviour longitudinally. Adolescents (N = 494) aged 11-16 years and not currently smoking at baseline participated in the study. Predictive validity of PMT constructs was tested in a path analysis model. Self-efficacy significantly predicted behavioural intention at baseline, which significantly predicted behavioural intention at follow-up, which in turn predicted smoking behaviour at follow-up. The effect of self-efficacy on behavioural intention at follow-up was mediated by behavioural intention at baseline and the effect of self-efficacy on smoking behaviour was mediated by behavioural intention at baseline and follow-up. In conclusion, we found support for one part of the PMT, namely for the predictive validity of the coping appraisal construct self-efficacy in predicting adolescents' smoking-related behavioural intention and smoking behaviour. These results fail to support the appropriateness of the PMT's construct threat appraisal in longitudinally predicting adolescents' smoking as well as the applicability of communicating fear and negative information as preventive interventions for this target group.
A remotely triggered fast neutron detection instrument based on a plastic organic scintillator
NASA Astrophysics Data System (ADS)
Jones, A. R.; Aspinall, M. D.; Joyce, M. J.
2018-02-01
A detector system for the characterization of radiation fields of both fast neutrons and γ rays is described comprising of a gated photomultiplier tube (PMT), an EJ299-33 solid organic scintillator detector, and an external trigger circuit. The objective of this development was to conceive a means by which the PMT in such a system can be actuated remotely during the high-intensity bursts of pulsed γ-ray contamination that can arise during active interrogation procedures. The system is used to detect neutrons and γ rays using established pulse-shape discrimination (PSD) techniques. The gating circuit enables the PMT to be switched off remotely. This is compatible with use during intense radiation transients to avoid saturation and the disruption of the operation of the PMT during the burst. Data are presented in the form of pulse-height spectra and PSD scatter plots for the system triggered with a strobed light source. These confirm that the gain of the system and the throughput for both triggered and un-triggered scenarios are as expected, given the duty cycle of the stimulating radiation. This demonstrates that the triggering function does not perturb the system response of the detector.
A remotely triggered fast neutron detection instrument based on a plastic organic scintillator.
Jones, A R; Aspinall, M D; Joyce, M J
2018-02-01
A detector system for the characterization of radiation fields of both fast neutrons and γ rays is described comprising of a gated photomultiplier tube (PMT), an EJ299-33 solid organic scintillator detector, and an external trigger circuit. The objective of this development was to conceive a means by which the PMT in such a system can be actuated remotely during the high-intensity bursts of pulsed γ-ray contamination that can arise during active interrogation procedures. The system is used to detect neutrons and γ rays using established pulse-shape discrimination (PSD) techniques. The gating circuit enables the PMT to be switched off remotely. This is compatible with use during intense radiation transients to avoid saturation and the disruption of the operation of the PMT during the burst. Data are presented in the form of pulse-height spectra and PSD scatter plots for the system triggered with a strobed light source. These confirm that the gain of the system and the throughput for both triggered and un-triggered scenarios are as expected, given the duty cycle of the stimulating radiation. This demonstrates that the triggering function does not perturb the system response of the detector.
Characterization of O-mannosyltransferase family in Schizosaccharomyces pombe.
Tanaka, Naotaka; Fujita, Yasuko; Suzuki, Shotaro; Morishita, Masayo; Giga-Hama, Yuko; Shimoda, Chikashi; Takegawa, Kaoru
2005-05-13
Protein O-glycosylation is an essential protein modification in eukaryotic cells. In Saccharomyces cerevisiae, O-mannosylation is initiated in the lumen of the endoplasmic reticulum by O-mannosyltransferase gene products (Pmt1p-7p). A search of the Schizosaccharomyces pombe genome database revealed a total of three O-glycoside mannosyltransferase homologs (ogm1+, ogm2+, and ogm4+), closely related to Saccharomyces cerevisiae PMT1, PMT2, and PMT4. Although individual ogm genes were not found to be essential, ogm1Delta and ogm4Delta mutants exhibited aberrant morphology and failed to agglutinate during mating. The phenotypes of the ogm4Delta mutant were not complemented by overexpression of ogm1+ or ogm2+, suggesting that each of the Ogm proteins does not have overlapping functions. Heterologous expression of a chitinase from S. cerevisiae in the ogm mutants revealed that O-glycosylation of chitinase had decreased in ogm1Delta cells. A GFP-tagged Fus1p from S. cerevisiae was specifically not glycosylated and accumulated in the Golgi in ogm4Delta cells. These results indicate that O-glycosylation initiated by Ogm proteins plays crucial physiological roles and can serve as a sorting determinant for protein transport of membrane glycoproteins in S. pombe.
Watanuki, Shoichi; Tashiro, Manabu; Miyake, Masayasu; Ishikawa, Yoichi; Itoh, Masatoshi; Yanai, Kazuhiko; Sakemi, Yasuhiro; Fukuda, Hiroshi; Ishii, Keizo
2010-07-01
Positron emission tomography (PET) scanners require periodic monitoring in order to maintain scanner performance. The aim of the present study was to examine the deterioration of PET scanner performance caused by aging. We retrospectively examined PET scanner performance alterations in terms of sensitivity, spatial resolution, false coincidences due to scatter and random coincidences based on 13 years of follow-up data, including data when the PET scanner underwent an overhaul at the 10th year after installation. Sensitivity and scatter fraction were calculated by using cross calibration factor (CCF) measurement data, which are collected routinely. Efficacy of the examining the sensitivity and scatter was confirmed by NEMA measurements. Trans-axial resolution was measured as full width at half-maximum (FWHM) and full width at tenth-maximum (FWTM) at 0-20 cm offset from the field of view (FOV) center at the time of installation, 8 years after installation, and immediately after the overhaul. Random coincidence rate fraction was measured in a wide range of count rates before and after the overhaul. The results indicated that the total reduction of sensitivity during the first 10 years was 41% of the initial value in terms of NEMA measurement, and that the annual reduction of sensitivity progressed at a rate of 4.7% per year in terms of CCF measurement data. The changes in sensitivity can be calculated using CCF measurement data. Regarding the spatial resolution, mean FWHM and FWTM values were increased by 1.7 and 3.6%, respectively, in 8 years after installation. The relative scatter fraction was significantly increased compared with that before the overhaul. The random fraction decreased by 10-15% after the overhaul within a certain range of random count rates (1-120 kcps). In the case of our scanner, the parameter that displayed the largest change was the sensitivity, and this change was thought to be caused by the reduction of photomultiplier tube (PMT) gain, although the changes in PMT gain can cause various types of performance deterioration, as investigated in this study. We observed that the sensitivity of our PET scanner generally deteriorated due to aging. Sensitivity monitoring using CCF measurements can be an easy and useful method for monitoring and maintaining the performance of PET scanners against aging. Since the data were obtained from a single scanner, the authors would encourage the initiation of a follow-up study involving various scanners.
Characterization of photomultiplier tubes with a realistic model through GPU-boosted simulation
NASA Astrophysics Data System (ADS)
Anthony, M.; Aprile, E.; Grandi, L.; Lin, Q.; Saldanha, R.
2018-02-01
The accurate characterization of a photomultiplier tube (PMT) is crucial in a wide-variety of applications. However, current methods do not give fully accurate representations of the response of a PMT, especially at very low light levels. In this work, we present a new and more realistic model of the response of a PMT, called the cascade model, and use it to characterize two different PMTs at various voltages and light levels. The cascade model is shown to outperform the more common Gaussian model in almost all circumstances and to agree well with a newly introduced model independent approach. The technical and computational challenges of this model are also presented along with the employed solution of developing a robust GPU-based analysis framework for this and other non-analytical models.
Enhanced photon traps for Hyper-Kamiokande
NASA Astrophysics Data System (ADS)
Rott, Carsten; In, Seongjin; Retière, Fabrice; Gumplinger, Peter
2017-11-01
Hyper-Kamiokande, the next generation large water Cherenkov detector in Japan, is planning to use approximately 80,000 20-inch photomultiplier tubes (PMTs). They are one of the major cost factors of the experiment. We propose a novel enhanced photon trap design based on a smaller and more economical PMT in combination with wavelength shifters, dichroic mirrors, and broadband mirrors. GEANT4 is utilized to obtain photon collection efficiencies and timing resolution of the photon traps. We compare the performance of different trap configurations and sizes. Our simulations indicate an enhanced photon trap with a 12-inch PMT can match a 20-inch PMT's collection efficiency, however at a cost of reduced timing resolution. The photon trap might be suitable as detection module for the outer detector with large photo coverage area.
Systematic studies of small scintillators for new sampling calorimeter
NASA Astrophysics Data System (ADS)
Jacosalem, E. P.; Iba, S.; Nakajima, N.; Ono, H.; Sanchez, A. L. C.; Bacala, A. M.; Miyata, H.
2007-12-01
A new sampling calorimeter using very thin scintillators and the multi-pixel photon counter (MPPC) has been proposed to produce better position resolution for the international linear collider (ILC) experiment. As part of this R&D study, small plastic scintillators of different sizes, thickness and wrapping reflectors are systematically studied. The scintillation light due to beta rays from a collimated ^{90}Sr source are collected from the scintillator by wavelength-shifting (WLS) fiber and converted into electrical signals at the PMT. The wrapped scintillator that gives the best light yield is determined by comparing the measured pulse height of each 10 × 40 × 2 mm strip scintillator covered with 3M reflective mirror film, teflon, white paint, black tape, gold, aluminum and white paint+teflon. The pulse height dependence on position, length and thickness of the 3M reflective mirror film and teflon wrapped scintillators are measured. Results show that the 3M radiant mirror film-wrapped scintillator has the greatest light yield with an average of 9.2 photoelectrons. It is observed that light yield slightly increases with scintillator length, but increases to about 100% when WLS fiber diameter is increased from 1.0 mm to 1.6 mm. The position dependence measurement along the strip scintillator showed the uniformity of light transmission from the sensor to the PMT. A dip across the strip is observed which is 40% of the maximum pulse height. The block type scintillator pulse height, on the other hand, is found to be almost proportional to scintillator thickness.
ERIC Educational Resources Information Center
Fey, Marc E.; Warren, Steven F.; Brady, Nancy; Finestack, Lizbeth H.; Bredin-Oja, Shelley L.; Fairchild, Martha; Sokol, Shari; Yoder, Paul J.
2006-01-01
Purpose: To evaluate the efficacy of a 6-month course of responsivity education/prelinguistic milieu teaching (RE/PMT) for children with developmental delay and RE/PMT's effects on parenting stress in a randomized clinical trial. Method: Fifty-one children, age 24-33 months, with no more than 10 expressive words or signs, were randomly assigned to…
Westcott, Rachel; Ronan, Kevin; Bambrick, Hilary; Taylor, Melanie
2017-04-26
Protection Motivation Theory (PMT) was developed by Rogers in 1975, to describe how individuals are motivated to react in a self-protective way towards a perceived health threat. Rogers expected the use of PMT to diversify over time, which has proved true over four decades. The purpose of this paper is to explore how PMT can be used and expanded to inform and improve public safety strategies in natural hazards. As global climate change impacts on the Australian environment, natural hazards seem to be increasing in scale and frequency, and Emergency Services' public education campaigns have necessarily escalated to keep pace with perceived public threat. Of concern, is that the awareness-preparedness gap in residents' survival plans is narrowing disproportionately slowly compared to the magnitude of resources applied to rectify this trend. Practical applications of adaptable social theory could be used to help resolve this dilemma. PMT has been used to describe human behaviour in individuals, families, and the parent-child unit. It has been applied to floods in Europe and wildfire and earthquake in the United States. This paper seeks to determine if an application of PMT can be useful for achieving other-directed human protection across a novel demographic spectrum in natural hazards, specifically, animal owners and emergency responders in bushfire emergencies. These groups could benefit from such an approach: owners to build and fortify their response- and self-efficacy, and to help translate knowledge into safer behaviour, and responders to gain a better understanding of a diverse demographic with animal ownership as its common denominator, and with whom they will be likely to engage in contemporary natural hazard management. Mutual collaboration between these groups could lead to a synergy of reciprocated response efficacy, and safer, less traumatic outcomes. Emergency services' community education programs have made significant progress over the last decade, but public safety remains suboptimal while the magnitude of the awareness-preparedness gap persists. This paper examines an expanded, other-directed application of PMT to expand and enhance safer mitigation and response behaviour strategies for communities threatened by bushfire, which may ultimately help save human life.
Performance of a specific algorithm to minimize right ventricular pacing: A multicenter study.
Strik, Marc; Defaye, Pascal; Eschalier, Romain; Mondoly, Pierre; Frontera, Antonio; Ritter, Philippe; Haïssaguerre, Michel; Ploux, Sylvain; Ellenbogen, Kenneth A; Bordachar, Pierre
2016-06-01
In Boston Scientific dual-chamber devices, the RYTHMIQ algorithm aims to minimize right ventricular pacing. We evaluated the performance of this algorithm determining (1) the appropriateness of the switch from the AAI(R) mode with backup VVI pacing to the DDD(R) mode in case of suspected loss of atrioventricular (AV) conduction and (2) the rate of recorded pacemaker-mediated tachycardia (PMT) when AV hysteresis searches for restored AV conduction. In this multicenter study, we included 157 patients with a Boston Scientific dual-chamber device (40 pacemakers and 117 implantable cardioverter-defibrillators) without permanent AV conduction disorder and with the RYTHMIQ algorithm activated. We reviewed the last 10 remote monitoring-transmitted RYTHMIQ and PMT episodes. We analyzed 1266 episodes of switch in 142 patients (90%): 207 (16%) were appropriate and corresponded to loss of AV conduction, and 1059 (84%) were inappropriate, of which 701 (66%) were related to compensatory pause (premature atrial contraction, 7%; premature ventricular contraction, 597 (56%); or both, 27 (3%)) or to a premature ventricular contraction falling in the post-atrial pacing ventricular refractory period interval (219, 21%) and 94 (10%) were related to pacemaker dysfunction. One hundred fifty-four PMT episodes were diagnosed in 27 patients (17%). In 85 (69%) of correctly diagnosed episodes, the onset of PMT was directly related to the algorithm-related prolongation of the AV delay, promoting AV dissociation and retrograde conduction. This study highlights some of the limitations of the RYTHMIQ algorithm: high rate of inappropriate switch and high rate of induction of PMT. This may have clinical implications in terms of selection of patients and may suggest required changes in the algorithm architecture. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Glendon, A Ian; Walker, Britta L
2013-08-01
The study investigated the effects of anti-speeding messages based on protection motivation theory (PMT) components: severity, vulnerability, rewards, self-efficacy, response efficacy, and response cost, on reported speeding intentions. Eighty-three participants aged 18-25 years holding a current Australian driver's license completed a questionnaire measuring their reported typical and recent speeding behaviors. Comparisons were made between 18 anti-speeding messages used on Australian roads and 18 new anti-speeding messages developed from the PMT model. Participants reported their reactions to the 36 messages on the perceived effectiveness of the message for themselves and for the general population of drivers, and also the likelihood of themselves and other drivers driving within the speed limit after viewing each message. Overall the PMT model-derived anti-speeding messages were better than jurisdiction-use anti-speeding messages in influencing participants' reported intention to drive within the speed limit. Severity and vulnerability were the most effective PMT components for developing anti-speeding messages. Male participants reported significantly lower intention to drive within the speed limit than did female participants. However, males reported significantly higher intention to drive within the speed limit for PMT-derived messages compared with jurisdiction-based messages. Third-person effects were that males reported anti-speeding messages to be more effective for the general driving population than for themselves. Females reported the opposite effect - that all messages would be more effective for themselves than for the general driving population. Findings provided support for using a sound conceptual basis as an effective foundation for anti-speeding message development as well as for evaluating proposed anti-speeding messages on the target driver population. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Greene, Amy
2013-04-01
MicroBooNE is a neutrino experiment at Fermilab designed to investigate the 3σ low-energy electron candidate events measured by the MiniBooNE experiment. Neutrinos from the Booster Neutrino Beam are detected by a 89-ton liquid argon time projection chamber, which is expected to start taking data in 2014. MicroBooNE measures both the ionization electrons and scintillation light produced by neutrino interactions in the liquid argon. The scintillation light is collected by an array of 30 PMTs located at one side of the detector. This array can be calibrated using Michel electrons from stopping cosmic ray muons, by fitting the measured PMT response with the theoretical expectation. I will report on the progress of the PMT calibration software that has been developed using the MicroBooNE Monte Carlo.
Ogawara, R; Ishikawa, M
2016-07-01
The anode pulse of a photomultiplier tube (PMT) coupled with a scintillator is used for pulse shape discrimination (PSD) analysis. We have developed a novel emulation technique for the PMT anode pulse based on optical photon transport and a PMT response function. The photon transport was calculated using Geant4 Monte Carlo code and the response function with a BC408 organic scintillator. The obtained percentage RMS value of the difference between the measured and simulated pulse with suitable scintillation properties using GSO:Ce (0.4, 1.0, 1.5 mol%), LaBr3:Ce and BGO scintillators were 2.41%, 2.58%, 2.16%, 2.01%, and 3.32%, respectively. The proposed technique demonstrates high reproducibility of the measured pulse and can be applied to simulation studies of various radiation measurements.
A new high-resolution PET scanner dedicated to brain research
NASA Astrophysics Data System (ADS)
Watanabe, M.; Shimizu, K.; Omura, T.; Takahashi, M.; Kosugi, T.; Yoshikawa, E.; Sato, N.; Okada, H.; Yamashita, T.
2002-06-01
A high-resolution positron emission tomography (PET) scanner dedicated to brain studies has been developed and its physical performance was evaluated. The block detector consists of a new compact position-sensitive photomultiplier tube (PS-PMT, Hamamatsu R7600-C12) and an 8/spl times/4 bismuth germanate (BGO) array. The size of each crystal is 2.8 mm/spl times/6.55 mm/spl times/30 mm. The system has a total of 11 520 crystals arranged in 24 detector rings 508 mm in diameter (480 per ring). The field of view (FOV) is 330 mm in diameter/spl times/163 mm, which is sufficient to measure the entire human brain. The diameter of the scanner's opening is equal to the transaxial FOV (330 mm). The system can be operated in three-dimensional (3-D) data acquisition mode, when the slice septa are retracted. The mechanical motions of the gantry and bed are specially designed to measure the patient in various postures; lying, sitting, and even standing postures. The spatial resolution of 2.9 mm in both the transaxial and axial directions is obtained at the center of the FOV. The total system sensitivity is 6.4 kc/s/kBq/ml in two-dimensional (2-D) mode, with a 20-cm-diameter cylindrical phantom. The imaging capabilities of the scanner were studied with the Hoffman brain phantom and with a normal volunteer.
Ultra-weak photon emission of hands in aging prediction.
Zhao, Xin; van Wijk, Eduard; Yan, Yu; van Wijk, Roeland; Yang, Huanming; Zhang, Yan; Wang, Jian
2016-09-01
Aging has been one of the several topics intensely investigated during recent decades. More scientists have been scrutinizing mechanisms behind the human aging process. Ultra-weak photon emission is known as one type of spontaneous photon emission that can be detected with a highly sensitive single photon counting photomultiplier tube (PMT) from the surface of human bodies. It may reflect the body's oxidative damage. Our aim was to examine whether ultra-weak photon emission from a human hand is able to predict one's chronological age. Sixty subjects were recruited and grouped by age. We examined four areas of each hand: palm side of fingers, palm side of hand, dorsum side of fingers, and dorsum side of hand. Left and right hand were measured synchronously with two independent PMTs. Mean strength and Fano factor values of photon counts were utilized to compare the UPE patterns of males and females of different age groups. Subsequently, we utilized UPE data from the most sensitive PMT to develop an age prediction model. We randomly picked 49 subjects to construct the model, whereas the remaining 11 subjects were utilized for validation. The results demonstrated that the model was a good regression compared to the observed values (Pearson's r=0.6, adjusted R square=0.4, p=9.4E-7, accuracy=49/60). Further analysis revealed that the average difference between the chronological age and predicted age was only 7.6±0.8years. It was concluded that this fast and non-invasive photon technology is sufficiently promising to be developed for the estimation of biological aging. Copyright © 2016 Elsevier B.V. All rights reserved.
Redesigned β γ radioxenon detector
NASA Astrophysics Data System (ADS)
Cooper, Matthew W.; McIntyre, Justin I.; Bowyer, Ted W.; Carman, April J.; Hayes, James C.; Heimbigner, Tom R.; Hubbard, Charles W.; Lidey, Lance; Litke, Kevin E.; Morris, Scott J.; Ripplinger, Michael D.; Suarez, Reynold; Thompson, Robert
2007-08-01
The Automated Radio-xenon Sampler/Analyzer (ARSA), designed by Pacific Northwest National Laboratory (PNNL) collects and detects several radioxenon isotopes, and is used to monitor underground nuclear explosions. The ARSA is very sensitive to 133Xe, 131mXe, 133mXe, and 135Xe (<1 mBq/SCM) [M. Auera et al., Wernspergera, Appl. Radiat. 6 (2004) 60] through use of its compact high efficiency β-γ coincidence detector. For this reason, it is an excellent treaty monitoring system and it can be used as an environmental sampling device as well. Field testing of the ARSA has shown it to be both robust and reliable, but the nuclear detector requires a detailed photomultiplier tube (PMT) gain matching regime difficult to implement in a field environment. Complexity is a problem from a maintenance and quality assurance/quality control (QA/QC) standpoint, and efforts to reduce these issues have led to development of a simplified β-γ coincident detector. The new design reduces the number of PMT's and the complexity of the calibration needed in comparison to the old design. New scintillation materials (NaI(Tl), CsI(Na), and CsI(Tl)) were investigated and a comparison of three different gamma sensitive well detectors has been completed. A new plastic-scintillator gas cell was constructed and a new method of forming the scintillator gas cell was developed. The simplified detector system compares favorably with the original ARSA design in spectral resolution and efficiency and is significantly easier to set up and calibrate. The new materials and configuration allow the resulting β-γ coincidence detector to maintain the overall performance of the ARSA type β-γ detector while simplifying the design.
Design of remote laser-induced fluorescence system's acquisition circuit
NASA Astrophysics Data System (ADS)
Wang, Guoqing; Lou, Yue; Wang, Ran; Yan, Debao; Li, Xin; Zhao, Xin; Chen, Dong; Zhao, Qi
2017-10-01
Laser-induced fluorescence system(LIfS) has been found its significant application in identifying one kind of substance from another by its properties even it's thimbleful, and becomes useful in plenty of fields. Many superior works have reported LIfS' theoretical analysis , designs and uses. However, the usual LIPS is always constructed in labs to detect matter quite closely, for the system using low-power laser as excitation source and charge coupled device (CCD) as detector. Promoting the detectivity of LIfS is of much concern to spread its application. Here, we take a high-energy narrow-pulse laser instead of commonly used continuous wave laser to operate sample, thus we can get strong fluorescent. Besides, photomultiplier (PMT) with high sensitivity is adopted in our system to detect extremely weak fluorescence after a long flight time from the sample to the detector. Another advantage in our system, as the fluorescence collected into spectroscopy, multiple wavelengths of light can be converted to the corresponding electrical signals with the linear array multichannel PMT. Therefore, at the cost of high-powered incentive and high-sensitive detector, a remote LIFS is get. In order to run this system, it is of importance to turn light signal to digital signal which can be processed by computer. The pulse width of fluorescence is deeply associated with excitation laser, at the nanosecond(ns) level, which has a high demand for acquisition circuit. We design an acquisition circuit including, I/V conversion circuit, amplifying circuit and peak-holding circuit. The simulation of circuit shows that peak-holding circuit can be one effective approach to reducing difficulty of acquisition circuit.
Graphic gambling warnings: how they affect emotions, cognitive responses and attitude change.
Muñoz, Yaromir; Chebat, Jean-Charles; Borges, Adilson
2013-09-01
The present study focuses on the effects of graphic warnings related to excessive gambling. It is based upon a theoretical model derived from both the Protection Motivation Theory (PMT) and the Elaboration Likelihood Model (ELM). We focus on video lottery terminal (VLT), one of the most hazardous format in the gaming industry. Our cohort consisted of 103 actual gamblers who reported previous gambling activity on VLT's on a regular basis. We assess the effectiveness of graphic warnings vs. text-only warnings and the effectiveness of two major arguments (i.e., family vs. financial disruption). A 2 × 2 factorial design was used to test the direct and combined effects of two variables (i.e., warning content and presence vs. absence of a graphic). It was found that the presence of a graphic enhances both cognitive appraisal and fear, and has positive effects on the Depth of Information Processing. In addition, graphic content combined with family disruptions is more effective for changing attitudes and complying with the warning than other combinations of the manipulated variables. It is proposed that ELM and PMT complement each other to explain the effects of warnings. Theoretical and practical implications are discussed.
2013-12-01
tight aluminum box internal view. Each SiPMT is held securely in each aluminum jig with nylon washers and screws. The threaded rod extends length-wise...hole in the aluminum jig located between the threaded rod and nylon screw is the hole where the single BCF-12 scintillating fiber would be placed to...additional pixel firing from the SiPMT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 42 A typical Hamamatsu
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ogawara, R.; Ishikawa, M., E-mail: masayori@med.hokudai.ac.jp
The anode pulse of a photomultiplier tube (PMT) coupled with a scintillator is used for pulse shape discrimination (PSD) analysis. We have developed a novel emulation technique for the PMT anode pulse based on optical photon transport and a PMT response function. The photon transport was calculated using Geant4 Monte Carlo code and the response function with a BC408 organic scintillator. The obtained percentage RMS value of the difference between the measured and simulated pulse with suitable scintillation properties using GSO:Ce (0.4, 1.0, 1.5 mol%), LaBr{sub 3}:Ce and BGO scintillators were 2.41%, 2.58%, 2.16%, 2.01%, and 3.32%, respectively. The proposedmore » technique demonstrates high reproducibility of the measured pulse and can be applied to simulation studies of various radiation measurements.« less
Wu, Ying; Stanton, Bonita F; Li, Xiaoming; Galbraith, Jennifer; Cole, Matthew L
2005-03-01
To assess health protection motivation as explained by the constructs of protection motivation theory (PMT) and its association with drug trafficking over 2 years. The sample included 817 African American youth (13-16 years old) participating in an adolescent risk-reduction program. We developed an instrument measuring the level of health protection motivation (LHPM) using factor analysis. Changes in LHPM over time were examined among drug traffickers, abstainers, initiators, and nonrisk youths. In sum, 151 participants reported selling and/or delivering drugs during the study period. The significant inverse correlation between drug-trafficking intention and health protection motivation was consistent with PMT. Changes in LHPM were strongly associated with the dynamics of behavior over 2 years. Adolescent drug trafficking can be predicted by an overall level of health protection motivation. PMT and related theories should be considered in the design of drug-trafficking prevention intervention.
Reducing skin cancer risk: an intervention based on protection motivation theory.
McClendon, B T; Prentice-Dunn, S
2001-05-01
Caucasian college students who intentionally tanned participated in a brief skin cancer intervention based on protection motivation theory (PMT). This intervention targeted skin appearance and consisted of brief lectures, a comprehensive essay, video clips about a young man who died of melanoma, and short discussions. Compared to a waitlist control group, the intervention group showed increases on PMT variables and intentions at post-test. The waitlist group later received the intervention and showed similar increases. Additionally, all but one PMT variable maintained post-test levels at a one-month follow-up. Photographs taken at post-test and at the one-month follow-up were judged by raters blind to the hypothesis. Seventy-two percent of participants were judged to have lighter skin whereas only 16 percent had darker skin. These results provide additional support for theory-based methods for changing maladaptive attitudes and behaviors associated with skin cancer risk.
Correlates of Protective Motivation Theory (PMT) to Adolescents’ Drug Use Intention
Wu, Cynthia Sau Ting; Wong, Ho Ting; Chou, Lai Yan; To, Bobby Pak Wai; Lee, Wai Lok; Loke, Alice Yuen
2014-01-01
Early onset and increasing proliferation of illicit adolescent drug-use poses a global health concern. This study aimed to examine the correlation between Protective Motivation Theory (PMT) measures and the intention to use drugs among adolescents. An exploratory quantitative correlation design and convenience sampling were adopted. A total of 318 students completed a self-reported questionnaire that solicited information related to their demographics and activities, measures of threat appraisal and coping appraisal, and the intention to use drugs. Logistic regression analysis showed that intrinsic and extrinsic rewards were significant predictors of intention. The odds ratios were equal to 2.90 (p < 0.05) and 8.04 (p < 0.001), respectively. The logistic regression model analysis resulted in a high Nagelkerke R2 of 0.49, which suggests that PMT related measures could be used in predicting drug use intention among adolescents. Further research should be conducted with non-school adolescents to confirm the application. PMID:24394215
Correlates of Protective Motivation Theory (PMT) to adolescents' drug use intention.
Wu, Cynthia Sau Ting; Wong, Ho Ting; Chou, Lai Yan; To, Bobby Pak Wai; Lee, Wai Lok; Loke, Alice Yuen
2014-01-03
Early onset and increasing proliferation of illicit adolescent drug-use poses a global health concern. This study aimed to examine the correlation between Protective Motivation Theory (PMT) measures and the intention to use drugs among adolescents. An exploratory quantitative correlation design and convenience sampling were adopted. A total of 318 students completed a self-reported questionnaire that solicited information related to their demographics and activities, measures of threat appraisal and coping appraisal, and the intention to use drugs. Logistic regression analysis showed that intrinsic and extrinsic rewards were significant predictors of intention. The odds ratios were equal to 2.90 (p < 0.05) and 8.04 (p < 0.001), respectively. The logistic regression model analysis resulted in a high Nagelkerke R2 of 0.49, which suggests that PMT related measures could be used in predicting drug use intention among adolescents. Further research should be conducted with non-school adolescents to confirm the application.
NASA Astrophysics Data System (ADS)
Faham, C. H.; Gehman, V. M.; Currie, A.; Dobi, A.; Sorensen, P.; Gaitskell, R. J.
2015-09-01
Measurements of double photoelectron emission (DPE) probabilities as a function of wavelength are reported for Hamamatsu R8778, R8520, and R11410 VUV-sensitive photomultiplier tubes (PMTs). In DPE, a single photon strikes the PMT photocathode and produces two photoelectrons instead of a single one. It was found that the fraction of detected photons that result in DPE emission is a function of the incident photon wavelength, and manifests itself below ~250 nm. For the xenon scintillation wavelength of 175 nm, a DPE probability of 18-24% was measured depending on the tube and measurement method. This wavelength-dependent single photon response has implications for the energy calibration and photon counting of current and future liquid xenon detectors such as LUX, LZ, XENON100/1T, Panda-X and XMASS.
Fluorescence detection system for microfluidic droplets
NASA Astrophysics Data System (ADS)
Chen, Binyu; Han, Xiaoming; Su, Zhen; Liu, Quanjun
2018-05-01
In microfluidic detection technology, because of the universality of optical methods in laboratory, optical detection is an attractive solution for microfluidic chip laboratory equipment. In addition, the equipment with high stability and low cost can be realized by integrating appropriate optical detection technology on the chip. This paper reports a detection system for microfluidic droplets. Photomultiplier tubes (PMT) is used as a detection device to improve the sensitivity of detection. This system improves the signal to noise ratio by software filtering and spatial filter. The fluorescence intensity is proportional to the concentration of the fluorescence and intensity of the laser. The fluorescence micro droplets of different concentrations can be distinguished by this system.
Marginalized Women in West Iran
Malmir, Shabnam; Barati, Majid; Khani Jeihooni, Ali; Bashirian, Saeed; Hazavehei, Seyed Mohammad Mehdi
2018-03-27
Objective: This study aimed to determine the effectiveness of an educational intervention to prevent cervical cancer among marginalized Iranianwomen based on the Protection Motivation Theory (PMT) as a theoretical framework. Methods: This quasi-experimental study was carried out on 143 women of Kermanshah City in western Iran during 2017. Participants were recruited through cluster and simple random sampling and randomly divided into experimental (n=72) and control groups (n=71). All completed a self-administered questionnaire including PMT constructs and demographic variables. An intervention over six sessions was then applied to the experimental group. Reassessment was conducted three months after the intervention, with data was analyzed with SPSS-16 using chi-square, McNemar, paired T- and independent T-tests. Results: The mean scores for the constructs of PMT, and cervical cancer screening behavior showed no significant differences between the two groups before the intervention (P>0.05). The educational manipulation had significant effects on the experimental groups’ average response for perceived vulnerability, perceived severity, perceived reward, self-efficacy, response efficacy, response cost and protection motivation (all p < 0.001). Also, the prevalence of regular Pap smear testing and referral to health centers were significantly increased after 3 months in the experimental (P=0.048), but notthe control group (P>0.05). Conclusions: The results show that applying an educational intervention based on PMT might help prevent cervical cancer and improve regular Pap smear testing. Creative Commons Attribution License
Inertial bioluminescence rhythms at the Capo Passero (KM3NeT-Italia) site, Central Mediterranean Sea
Aguzzi, J.; Fanelli, E.; Ciuffardi, T.; Schirone, A.; Craig, J.; Aiello, S.; Ameli, F.; Anghinolfi, M.; Barbarino, G.; Barbarito, E.; Beverini, N.; Biagi, S.; Biagioni, A.; Bouhadef, B.; Bozza, C.; Cacopardo, G.; Calamai, M.; Calì, C.; Capone, A.; Caruso, F.; Cecchini, S.; Ceres, A.; Chiarusi, T.; Circella, M.; Cocimano, R.; Coniglione, R.; Costa, M.; Cuttone, G.; D’Amato, C.; D’Amico, A.; De Bonis, G.; De Luca, V.; Deniskina, N.; Distefano, C.; Di Mauro, L. S.; Fermani, P.; Ferrara, G.; Flaminio, V.; Fusco, L. A.; Garufi, F.; Giordano, V.; Gmerk, A.; Grasso, R.; Grella, G.; Hugon, C.; Imbesi, M.; Kulikovskiy, V.; Larosa, G.; Lattuada, D.; Leismüller, K. P.; Leonora, E.; Litrico, P.; Lonardo, A.; Longhitano, F.; Presti, D. Lo; Maccioni, E.; Margiotta, A.; Marinelli, A.; Martini, A.; Masullo, R.; Mele, R.; Migliozzi, P.; Migneco, E.; Miraglia, A.; Mollo, C. M.; Mongelli, M.; Morganti, M.; Musico, P.; Musumeci, M.; Nicolau, C. A.; Orlando, A.; Orzelli, A.; Papaleo, R.; Pellegrino, C.; Pellegriti, M. G.; Perrina, C.; Piattelli, P.; Poma, E.; Pulvirenti, S.; Raffaelli, F.; Randazzo, N.; Riccobene, G.; Rovelli, A.; Sanguineti, M.; Sapienza, P.; Sciacca, V.; Sgura, I.; Simeone, F.; Sipala, V.; Speziale, F.; Spitaleri, A.; Spurio, M.; Stellacci, S. M.; Taiuti, M.; Terreni, G.; Trasatti, L.; Trovato, A.; Versari, F.; Vicini, P.; Viola, S.; Vivolo, D.
2017-01-01
In the deep sea, the sense of time is dependent on geophysical fluctuations, such as internal tides and atmospheric-related inertial currents, rather than day-night rhythms. Deep-sea neutrino telescopes instrumented with light detecting Photo-Multiplier Tubes (PMT) can be used to describe the synchronization of bioluminescent activity of abyssopelagic organisms with hydrodynamic cycles. PMT readings at 8 different depths (from 3069 to 3349 m) of the NEMO Phase 2 prototype, deployed offshore Capo Passero (Sicily) at the KM3NeT-Italia site, were used to characterize rhythmic bioluminescence patterns in June 2013, in response to water mass movements. We found a significant (p < 0.05) 20.5 h periodicity in the bioluminescence signal, corresponding to inertial fluctuations. Waveform and Fourier analyses of PMT data and tower orientation were carried out to identify phases (i.e. the timing of peaks) by subdividing time series on the length of detected inertial periodicity. A phase overlap between rhythms and cycles suggests a mechanical stimulation of bioluminescence, as organisms carried by currents collide with the telescope infrastructure, resulting in the emission of light. A bathymetric shift in PMT phases indicated that organisms travelled in discontinuous deep-sea undular vortices consisting of chains of inertially pulsating mesoscale cyclones/anticyclones, which to date remain poorly known. PMID:28332561
Inertial bioluminescence rhythms at the Capo Passero (KM3NeT-Italia) site, Central Mediterranean Sea
NASA Astrophysics Data System (ADS)
Aguzzi, J.; Fanelli, E.; Ciuffardi, T.; Schirone, A.; Craig, J.; Aiello, S.; Ameli, F.; Anghinolfi, M.; Barbarino, G.; Barbarito, E.; Beverini, N.; Biagi, S.; Biagioni, A.; Bouhadef, B.; Bozza, C.; Cacopardo, G.; Calamai, M.; Calì, C.; Capone, A.; Caruso, F.; Cecchini, S.; Ceres, A.; Chiarusi, T.; Circella, M.; Cocimano, R.; Coniglione, R.; Costa, M.; Cuttone, G.; D'Amato, C.; D'Amico, A.; de Bonis, G.; de Luca, V.; Deniskina, N.; Distefano, C.; di Mauro, L. S.; Fermani, P.; Ferrara, G.; Flaminio, V.; Fusco, L. A.; Garufi, F.; Giordano, V.; Gmerk, A.; Grasso, R.; Grella, G.; Hugon, C.; Imbesi, M.; Kulikovskiy, V.; Larosa, G.; Lattuada, D.; Leismüller, K. P.; Leonora, E.; Litrico, P.; Lonardo, A.; Longhitano, F.; Presti, D. Lo; Maccioni, E.; Margiotta, A.; Marinelli, A.; Martini, A.; Masullo, R.; Mele, R.; Migliozzi, P.; Migneco, E.; Miraglia, A.; Mollo, C. M.; Mongelli, M.; Morganti, M.; Musico, P.; Musumeci, M.; Nicolau, C. A.; Orlando, A.; Orzelli, A.; Papaleo, R.; Pellegrino, C.; Pellegriti, M. G.; Perrina, C.; Piattelli, P.; Poma, E.; Pulvirenti, S.; Raffaelli, F.; Randazzo, N.; Riccobene, G.; Rovelli, A.; Sanguineti, M.; Sapienza, P.; Sciacca, V.; Sgura, I.; Simeone, F.; Sipala, V.; Speziale, F.; Spitaleri, A.; Spurio, M.; Stellacci, S. M.; Taiuti, M.; Terreni, G.; Trasatti, L.; Trovato, A.; Versari, F.; Vicini, P.; Viola, S.; Vivolo, D.
2017-03-01
In the deep sea, the sense of time is dependent on geophysical fluctuations, such as internal tides and atmospheric-related inertial currents, rather than day-night rhythms. Deep-sea neutrino telescopes instrumented with light detecting Photo-Multiplier Tubes (PMT) can be used to describe the synchronization of bioluminescent activity of abyssopelagic organisms with hydrodynamic cycles. PMT readings at 8 different depths (from 3069 to 3349 m) of the NEMO Phase 2 prototype, deployed offshore Capo Passero (Sicily) at the KM3NeT-Italia site, were used to characterize rhythmic bioluminescence patterns in June 2013, in response to water mass movements. We found a significant (p < 0.05) 20.5 h periodicity in the bioluminescence signal, corresponding to inertial fluctuations. Waveform and Fourier analyses of PMT data and tower orientation were carried out to identify phases (i.e. the timing of peaks) by subdividing time series on the length of detected inertial periodicity. A phase overlap between rhythms and cycles suggests a mechanical stimulation of bioluminescence, as organisms carried by currents collide with the telescope infrastructure, resulting in the emission of light. A bathymetric shift in PMT phases indicated that organisms travelled in discontinuous deep-sea undular vortices consisting of chains of inertially pulsating mesoscale cyclones/anticyclones, which to date remain poorly known.
Tayi, Lavanya; Maku, Roshan V; Patel, Hitendra Kumar; Sonti, Ramesh V
2016-01-01
Xanthomonas oryzae pv.oryzae (Xoo) causes the serious bacterial blight disease of rice. Xoo secretes a repertoire of plant cell wall degrading enzymes (CWDEs) like cellulases, xylanases, esterases etc., which act on various components of the rice cell wall. The major cellulases and xylanases secreted by Xoo have been identified and their role in virulence has been determined. In this study, we have identified some of the pectin degrading enzymes of Xoo and assessed their role in virulence. Bioinformatics analysis indicated the presence of four pectin homogalacturonan (HG) degrading genes in the genome of Xoo. The four HG degrading genes include one polygalacturonase (pglA), one pectin methyl esterase (pmt) and two pectate lyases (pel and pelL). There was no difference in the expression of pglA, pmt and pel genes by laboratory wild type Xoo strain (BXO43) grown in either nutrient rich PS medium or in plant mimic XOM2 medium whereas the expression of pelL gene was induced in XOM2 medium as indicated by qRT-PCR experiments. Gene disruption mutations were generated in each of these four genes. The polygalacturonase mutant pglA- was completely deficient in degrading the substrate Na-polygalacturonicacid (PGA). Strains carrying mutations in the pmt, pel and pelL genes were as efficient as wild type Xoo (BXO43) in cleaving PGA. These observations clearly indicate that PglA is the major pectin degrading enzyme produced by Xoo. The pectin methyl esterase, Pmt, is the pectin de-esterifying enzyme secreted by Xoo as evident from the enzymatic activity assay performed using pectin as the substrate. Mutations in the pglA, pmt, pel and pelL genes have minimal effects on virulence. This suggests that, as compared to cellulases and xylanases, the HG degrading enzymes may not have a major role in the pathogenicity of Xoo.
Tayi, Lavanya; Maku, Roshan V.; Patel, Hitendra Kumar; Sonti, Ramesh V.
2016-01-01
Xanthomonas oryzae pv.oryzae (Xoo) causes the serious bacterial blight disease of rice. Xoo secretes a repertoire of plant cell wall degrading enzymes (CWDEs) like cellulases, xylanases, esterases etc., which act on various components of the rice cell wall. The major cellulases and xylanases secreted by Xoo have been identified and their role in virulence has been determined. In this study, we have identified some of the pectin degrading enzymes of Xoo and assessed their role in virulence. Bioinformatics analysis indicated the presence of four pectin homogalacturonan (HG) degrading genes in the genome of Xoo. The four HG degrading genes include one polygalacturonase (pglA), one pectin methyl esterase (pmt) and two pectate lyases (pel and pelL). There was no difference in the expression of pglA, pmt and pel genes by laboratory wild type Xoo strain (BXO43) grown in either nutrient rich PS medium or in plant mimic XOM2 medium whereas the expression of pelL gene was induced in XOM2 medium as indicated by qRT-PCR experiments. Gene disruption mutations were generated in each of these four genes. The polygalacturonase mutant pglA- was completely deficient in degrading the substrate Na-polygalacturonicacid (PGA). Strains carrying mutations in the pmt, pel and pelL genes were as efficient as wild type Xoo (BXO43) in cleaving PGA. These observations clearly indicate that PglA is the major pectin degrading enzyme produced by Xoo. The pectin methyl esterase, Pmt, is the pectin de-esterifying enzyme secreted by Xoo as evident from the enzymatic activity assay performed using pectin as the substrate. Mutations in the pglA, pmt, pel and pelL genes have minimal effects on virulence. This suggests that, as compared to cellulases and xylanases, the HG degrading enzymes may not have a major role in the pathogenicity of Xoo. PMID:27907079
Kristoffersen, Agnete E; Sirois, Fuschia M; Stub, Trine; Hansen, Anne Helen
2017-06-19
Engagement in healthy lifestyle behaviors, such as healthy diet and regular physical activity, are known to reduce the risk of developing coronary heart disease (CHD). Complementary and alternative medicine (CAM) is known to be associated with having a healthy lifestyle. The primary aim of this study was to examine the prevalence and predictors of CAM use in CHD patients, and in those without CHD but at risk for developing CHD, using Protection Motivation Theory (PMT) as a guiding conceptual framework. Questionnaire data were collected from 12,981 adult participants in the cross-sectional sixth Tromsø Study (2007-8). Eligible for analyses were 11,103 participants who reported whether they had used CAM or not. Of those, 830 participants reported to have or have had CHD (CHD group), 4830 reported to have parents, children or siblings with CHD (no CHD but family risk), while 5443 reported no CHD nor family risk of CHD. We first compared the patterns of CAM use in each group, and then examined the PMT predictors of CAM use. Health vulnerability from the threat appraisal process of PMT was assessed by self-rated health and expectations for future health. Response efficacy from the coping appraisal process of PMT was assessed as preventive health beliefs and health behavior frequency. Use of CAM was most commonly seen in people with no CHD themselves, but family risk of developing CHD (35.8%), compared to people already diagnosed with CHD (30.2%) and people with no CHD nor family risk (32.1%). All four of the PMT factors; self-rated health, expectations for future health, preventive health beliefs, and the health behavior index - were predictors for CAM use in the no CHD but family risk group. These findings suggest that people use CAM in response to a perceived risk of developing CHD, and to prevent disease and to maintain health.
NASA Astrophysics Data System (ADS)
Hall, J. A.; Felnagle, E.; Fries, M.; Spearing, S.; Monaco, L.; Steele, A.
2006-12-01
A Modular Assay System for Solar System Exploration (MASSE) is being developed to include sample handling, pre-treatment, separation and analysis of biological target compounds by both DNA and protein microarrays. To better design sensitive and accurate initial upstream sample handling of the MASSE instrument, experiments investigating the sensitivity and potential extraction bias of commercially available DNA extraction kits between classes of environmentally relevant prokaryotes such as gram-negative bacteria ( Escherichia coli), gram-positive bacteria ( Bacillus megatarium), and Archaea ( Haloarcula marismortui) were performed. For extractions of both planktonic cultures and spiked Mars simulated regolith, FTA ® paper demonstrated the highest sensitivity, with detection as low as ˜1×10 1 cells and ˜3.3×10 2 cells, respectively. In addition to the highest sensitivity, custom modified application of FTA ® paper extraction protocol is the simplest in terms of incorporation into MASSE and displayed little bias in sensitivity with respect to prokaryotic cell type. The implementation of FTA paper for environmental microbiology investigations appears to be a viable and effective option potentially negating the need for other pre-concentration steps such as filtration and negating concerns regarding extraction efficiency of cells. In addition to investigations on useful technology for upstream sample handling in MASSE, we have also evaluated the potential for μTAS to be employed in the MASSE instrument by employing proprietary lab-on-a-chip development technology to investigate the potential for microfluidic cell lysis of different prokaryotic cells employing both chemical and biological lysis agents. Real-time bright-field microscopy and quantitative PMT detection indicated that that gram positive, gram negative and archaeal cells were effectively lyzed in a few seconds using the microfluidic chip protocol developed. This included employing a lysis buffer with components including lysozyme, Protease, Proteinase K, Tween-20 and TritonX-100. The effectiveness of antibiotics and other chemical lysis agents were also screened and demonstrated partial effectiveness on all three cell types. This work demonstrates a step wise approach to evaluating the efficacy and sensitivity of commercial macro-scale technology and state-of-the-art developmental microfluidic technology under consideration for incorporation into the remotely operated MASSE instrument currently under development at the Carnegie Institution of Washington.
Performance of photomultiplier tubes and sodium iodide scintillation detector systems
NASA Technical Reports Server (NTRS)
Meegan, C. A.
1981-01-01
The performance of photomultiplier tubes (PMT's) and scintillation detector systems incorporating 50.8 by 1.27 cm NaI (T l) crystals was investigated to determine the characteristics of the photomultiplier tubes and optimize the detector geometry for the Burst and Transient Source Experiment on the Gamma Ray Observatory. Background information on performance characteristics of PMT's and NaI (T l) detectors is provided, procedures for measurement of relevant parameters are specified, and results of these measurements are presented.
Fundamental Study of Nuclear Pumped Laser Plasmas.
1980-12-23
PUMPED DYE LASER PMT PUMPING/ GAS HAND- LING SYSTEM ANODE SIGNAL TO SCREEN ROOM FIGURE 13 EXPERIMENTAL APPARATUS FROM ANODE OF PMT SCREEN ROOM...and G.A. Zdasiuk, " Laser Induced Collisional and Radiative Energy Transfer’, Proceedings of Laser Spectroscopy IV, June 1979. W. R. Green, M.D. Wright...AD-A130 988 FUNDAMENTAL STUDY 0F NUCLEAR PUMPED LASER PLASMAS(U) 1/ MIAMI UNIV OXFORD UHDi EPT OF PHYSIS Cs W DOWNES ET AL 23 DEC AS OASGAS 7A C OSAN
Another step towards photodetector innovation: The first 1-inch industrial VSiPMT
NASA Astrophysics Data System (ADS)
Barbarino, G.; Barbato, F. C. T.; Mollo, C. M.; Nocerino, E.; Vivolo, D.; Fukasawa, A.
2018-09-01
The VSiPMT (Vacuum Silicon PhotoMultiplier Tube) is an original design for an innovative light detector we proposed with the aim to create new scientific instrumentation for future missions of exploration and observation of the universe. The idea behind this device is to replace the classical dynode chain of a photomultiplier tube with a silicon photomultiplier, the latter acting as an electron detector and amplifier. In this way we obtain a large area photodetector with an excellent photon counting, proper of the SiPMs, but with the dark noise of only one SiPM (1-inch is equivalent to ∼ 54 SiPM 3 × 3 mm2). From this point of view, the VSiPMT offers very attractive features and unprecedented performance in large area detection, such as: negligible power consumption, excellent SPE resolution, easy low-voltage-based stabilization and very good time performance. Hamamatsu realized for our group a 1-inch prototype. The results of the full characterization of the device are presented in this work.
Development of a flexible γ-ray detector using a liquid scintillation light guide (LSLG).
Nomura, Kiyoshi; Yunoki, Akira; Hara, Masayuki; Morito, Yuko; Fujishima, Akira
2018-04-10
A flexible γ detector using a liquid scintillation light guide (LSLG) was developed. The analyzed pulse height (PHA) spectrum depended on the diameter, length and scintillator concentration of the LSLG, and the distance of a γ ray irradiation point from the head of photomultiplier tube (PMT). From the analysis of PHA spectrum, it was found that the count ratio of two divided channel regions linearly decreases as the distance from the PMT head increases. It was further found that the radiation dose rate can be estimated by setting the flexible LSLG tube to a circular shape since the count rate is proportional to the dose rate measured by a conventional NaI (Tl) scintillation detector. Therefore, a flexible and long LSLG detector using a single PMT is useful for determination of the dose rate and has a potential to detect local contaminations in a certain narrow space. Copyright © 2018. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andrews, Madison Theresa; Bates, Cameron Russell; Mckigney, Edward Allen
Here, this work presents the organic scintillation simulation capabilities of DRiFT, a post-processing Detector Response Function Toolkit for MCNPR output. DRiFT is used to create realistic scintillation detector response functions to incident neutron and gamma mixed- field radiation. As a post-processing tool, DRiFT leverages the extensively validated radiation transport capabilities of MCNPR ®6, which also provides the ability to simulate complex sources and geometries. DRiFT is designed to be flexible, it allows the user to specify scintillator material, PMT type, applied PMT voltage, and quenching data used in simulations. The toolkit's capabilities, which include the generation of pulse shape discriminationmore » plots and full-energy detector spectra, are demonstrated in a comparison of measured and simulated neutron contributions from 252Cf and PuBe, and photon spectra from 22Na and 228Th sources. DRiFT reproduced energy resolution effects observed in EJ-301 measurements through the inclusion of scintillation yield variances, photon transport noise, and PMT photocathode and multiplication noise.« less
Organic Scintillator Detector Response Simulations with DRiFT
Andrews, Madison Theresa; Bates, Cameron Russell; Mckigney, Edward Allen; ...
2016-06-11
Here, this work presents the organic scintillation simulation capabilities of DRiFT, a post-processing Detector Response Function Toolkit for MCNPR output. DRiFT is used to create realistic scintillation detector response functions to incident neutron and gamma mixed- field radiation. As a post-processing tool, DRiFT leverages the extensively validated radiation transport capabilities of MCNPR ®6, which also provides the ability to simulate complex sources and geometries. DRiFT is designed to be flexible, it allows the user to specify scintillator material, PMT type, applied PMT voltage, and quenching data used in simulations. The toolkit's capabilities, which include the generation of pulse shape discriminationmore » plots and full-energy detector spectra, are demonstrated in a comparison of measured and simulated neutron contributions from 252Cf and PuBe, and photon spectra from 22Na and 228Th sources. DRiFT reproduced energy resolution effects observed in EJ-301 measurements through the inclusion of scintillation yield variances, photon transport noise, and PMT photocathode and multiplication noise.« less
Organic scintillator detector response simulations with DRiFT
NASA Astrophysics Data System (ADS)
Andrews, M. T.; Bates, C. R.; McKigney, E. A.; Solomon, C. J.; Sood, A.
2016-09-01
This work presents the organic scintillation simulation capabilities of DRiFT, a post-processing Detector Response Function Toolkit for MCNP® output. DRiFT is used to create realistic scintillation detector response functions to incident neutron and gamma mixed-field radiation. As a post-processing tool, DRiFT leverages the extensively validated radiation transport capabilities of MCNP® 6 , which also provides the ability to simulate complex sources and geometries. DRiFT is designed to be flexible, it allows the user to specify scintillator material, PMT type, applied PMT voltage, and quenching data used in simulations. The toolkit's capabilities, which include the generation of pulse shape discrimination plots and full-energy detector spectra, are demonstrated in a comparison of measured and simulated neutron contributions from 252Cf and PuBe, and photon spectra from 22Na and 228Th sources. DRiFT reproduced energy resolution effects observed in EJ-301 measurements through the inclusion of scintillation yield variances, photon transport noise, and PMT photocathode and multiplication noise.
CCDiode: an optimal detector for laser confocal microscopes
NASA Astrophysics Data System (ADS)
Pawley, James B.; Blouke, Morley M.; Janesick, James R.
1996-04-01
The laser confocal microscope (LCM) is now an established research tool in biology and materials science. In biological applications, it is usually employed to detect the location of fluorescent market molecules and, under these conditions, signal levels from bright areas are often < 20 photons/pixel (from the specimen, assuming a standard 512 X 768, 1 sec. scan). Although this data rate limits the speed at which information can be derived from the specimen, saturation of the fluorophor, photobleaching of the dye, and phototoxicity prevent it being increased. Currently, most LCMs use photomultiplier tubes (PMT, QE equals 1 - 30% 400 - 900 nm). By contrast, rear-illuminated, scientific charge-coupled devices (CCD) now routinely readout the signal from square sensors approximately 30 micrometers on a side with a QE of 80 - 90%, a noise of only +/- 3 e-/pix and with no multiplicative noise. For this reason, in 1989, one of us (JJ) developed a rear-illuminated, single-channel Si sensor, called the Turbodiode, employing some of the sophisticated readout techniques used to measure charge in a scientific CCD. We are now extending this work to a device in which a single 36 X 36 micrometers sensor is read out through a low-noise FET charge amplifier with a reset circuit and then passed to a correlated, double-sampling digitizer. To maintain the desired +/- 3 e noise level at the relatively high data rate of 1 MHz, our new device utilizes 64 separate readout amplifier/digitizer systems, operating in sequence. The resulting detector is more compact, efficient and reliable than the PMT it replaces but as its sensitive area is smaller than that of a PMT, it will require auxiliary optics when used with any LCM having a large (mm) pinhole. As the signal light is parallel, a simple lens mounted axially and with the CCDiode at its focus would suffice. Future versions may use 3 X 3 or 5 X 5 arrays of sensors to `track' the confocal spot as it is deflected by inhomogeneities of the specimen, change its effective size or shape or detect system misalignment.
Lwin, May O.; Vijaykumar, Santosh; Foo, Schubert; Fernando, Owen Noel Newton; Lim, Gentatsu; Panchapakesan, Chitra; Wimalaratne, Prasad
2016-01-01
This article focuses on a novel social media-based system that addresses dengue prevention through an integration of three components: predictive surveillance, civic engagement and health education. The aim was to conduct a potential receptivity assessment of this system among smartphone users in the city of Colombo, the epicenter of the dengue epidemic in the island country of Sri Lanka. Grounded in Protection Motivation Theory (PMT) and using a convenience sampling approach, the cross-sectional survey assessed perceived severity (PSe), perceived susceptibility (PSu), perceived response efficacy (PRE), perceived self-efficacy (PSE) and intention-to-use (IU) among 513 individuals. The overall receptivity to the system was high with a score of >4.00 on a five-point scale. Participants belonging to younger, better educated and higher income groups reported significantly better perceptions of the efficaciousness of the system, were confident in their ability to use the system, and planned to use it in the future. PMT variables contributed significantly to regression models predicting IU. We concluded that a social media-based system for dengue prevention will be positively received among Colombo residents and a targeted, strategic health communication effort to raise dengue-related threat perceptions will be needed to encourage greater adoption and use of the system. PMID:26668207
The timing resolution of scintillation-detector systems: Monte Carlo analysis
NASA Astrophysics Data System (ADS)
Choong, Woon-Seng
2009-11-01
Recent advancements in fast scintillating materials and fast photomultiplier tubes (PMTs) have stimulated renewed interest in time-of-flight (TOF) positron emission tomography (PET). It is well known that the improvement in the timing resolution in PET can significantly reduce the noise variance in the reconstructed image resulting in improved image quality. In order to evaluate the timing performance of scintillation detectors used in TOF PET, we use Monte Carlo analysis to model the physical processes (crystal geometry, crystal surface finish, scintillator rise time, scintillator decay time, photoelectron yield, PMT transit time spread, PMT single-electron response, amplifier response and time pick-off method) that can contribute to the timing resolution of scintillation-detector systems. In the Monte Carlo analysis, the photoelectron emissions are modeled by a rate function, which is used to generate the photoelectron time points. The rate function, which is simulated using Geant4, represents the combined intrinsic light emissions of the scintillator and the subsequent light transport through the crystal. The PMT output signal is determined by the superposition of the PMT single-electron response resulting from the photoelectron emissions. The transit time spread and the single-electron gain variation of the PMT are modeled in the analysis. Three practical time pick-off methods are considered in the analysis. Statistically, the best timing resolution is achieved with the first photoelectron timing. The calculated timing resolution suggests that a leading edge discriminator gives better timing performance than a constant fraction discriminator and produces comparable results when a two-threshold or three-threshold discriminator is used. For a typical PMT, the effect of detector noise on the timing resolution is negligible. The calculated timing resolution is found to improve with increasing mean photoelectron yield, decreasing scintillator decay time and decreasing transit time spread. However, only substantial improvement in the timing resolution is obtained with improved transit time spread if the first photoelectron timing is less than the transit time spread. While the calculated timing performance does not seem to be affected by the pixel size of the crystal, it improves for an etched crystal compared to a polished crystal. In addition, the calculated timing resolution degrades with increasing crystal length. These observations can be explained by studying the initial photoelectron rate. Experimental measurements provide reasonably good agreement with the calculated timing resolution. The Monte Carlo analysis developed in this work will allow us to optimize the scintillation detectors for timing and to understand the physical factors limiting their performance.
The timing resolution of scintillation-detector systems: Monte Carlo analysis.
Choong, Woon-Seng
2009-11-07
Recent advancements in fast scintillating materials and fast photomultiplier tubes (PMTs) have stimulated renewed interest in time-of-flight (TOF) positron emission tomography (PET). It is well known that the improvement in the timing resolution in PET can significantly reduce the noise variance in the reconstructed image resulting in improved image quality. In order to evaluate the timing performance of scintillation detectors used in TOF PET, we use Monte Carlo analysis to model the physical processes (crystal geometry, crystal surface finish, scintillator rise time, scintillator decay time, photoelectron yield, PMT transit time spread, PMT single-electron response, amplifier response and time pick-off method) that can contribute to the timing resolution of scintillation-detector systems. In the Monte Carlo analysis, the photoelectron emissions are modeled by a rate function, which is used to generate the photoelectron time points. The rate function, which is simulated using Geant4, represents the combined intrinsic light emissions of the scintillator and the subsequent light transport through the crystal. The PMT output signal is determined by the superposition of the PMT single-electron response resulting from the photoelectron emissions. The transit time spread and the single-electron gain variation of the PMT are modeled in the analysis. Three practical time pick-off methods are considered in the analysis. Statistically, the best timing resolution is achieved with the first photoelectron timing. The calculated timing resolution suggests that a leading edge discriminator gives better timing performance than a constant fraction discriminator and produces comparable results when a two-threshold or three-threshold discriminator is used. For a typical PMT, the effect of detector noise on the timing resolution is negligible. The calculated timing resolution is found to improve with increasing mean photoelectron yield, decreasing scintillator decay time and decreasing transit time spread. However, only substantial improvement in the timing resolution is obtained with improved transit time spread if the first photoelectron timing is less than the transit time spread. While the calculated timing performance does not seem to be affected by the pixel size of the crystal, it improves for an etched crystal compared to a polished crystal. In addition, the calculated timing resolution degrades with increasing crystal length. These observations can be explained by studying the initial photoelectron rate. Experimental measurements provide reasonably good agreement with the calculated timing resolution. The Monte Carlo analysis developed in this work will allow us to optimize the scintillation detectors for timing and to understand the physical factors limiting their performance.
The high-speed after-pulse measurement system for PMT
NASA Astrophysics Data System (ADS)
Cheng, Y.; Qian, S.; Ning, Z.; Xia, J.; Wang, Z.
2018-05-01
A system employing a desktop FADC has been developed to investigate the features of 8-inch Hamamatsu PMT R5912. The system stands out for its high-speed and informative results as a consequence of adopting fast waveform sampling technology. Recording the full waveforms allows us to perform pulse shape analysis. High-precision after-pulse time and charge distribution results are presented in this manuscript. Other characteristics of the photomultiplier tube, such as the gain of charge, dark rate and transit time spread, can be also obtained by this system.
Impact of intense x-ray pulses on a NaI(Tl)-based gamma camera
NASA Astrophysics Data System (ADS)
Koppert, W. J. C.; van der Velden, S.; Steenbergen, J. H. L.; de Jong, H. W. A. M.
2018-03-01
In SPECT/CT systems x-ray and γ-ray imaging is performed sequentially. Simultaneous acquisition may have advantages, for instance in interventional settings. However, this may expose a gamma camera to relatively high x-ray doses and deteriorate its functioning. We studied the NaI(Tl) response to x-ray pulses with a photodiode, PMT and gamma camera, respectively. First, we exposed a NaI(Tl)-photodiode assembly to x-ray pulses to investigate potential crystal afterglow. Next, we exposed a NaI(Tl)-PMT assembly to 10 ms LED pulses (mimicking x-ray pulses) and measured the response to flashing LED probe-pulses (mimicking γ-pulses). We then exposed the assembly to x-ray pulses, with detector entrance doses of up to 9 nGy/pulse, and analysed the response for γ-pulse variations. Finally, we studied the response of a Siemens Diacam gamma camera to γ-rays while exposed to x-ray pulses. X-ray exposure of the crystal, read out with a photodiode, revealed 15% afterglow fraction after 3 ms. The NaI(Tl)-PMT assembly showed disturbances up to 10 ms after 10 ms LED exposure. After x-ray exposure however, responses showed elevated baselines, with 60 ms decay-time. Both for x-ray and LED exposure and after baseline subtraction, probe-pulse analysis revealed disturbed pulse height measurements shortly after exposure. X-ray exposure of the Diacam corroborated the elementary experiments. Up to 50 ms after an x-ray pulse, no events are registered, followed by apparent energy elevations up to 100 ms after exposure. Limiting the dose to 0.02 nGy/pulse prevents detrimental effects. Conventional gamma cameras exhibit substantial dead-time and mis-registration of photon energies up to 100 ms after intense x-ray pulses. This is due PMT limitations and due to afterglow in the crystal. Using PMTs with modified circuitry, we show that deteriorative afterglow effects can be reduced without noticeable effects on the PMT performance, up to x-ray pulse doses of 1 nGy.
Buehler, Tania; Kreis, Roland; Boesch, Chris
2015-02-01
(31)P MRS magnetization transfer ((31)P-MT) experiments allow the estimation of exchange rates of biochemical reactions, such as the creatine kinase equilibrium and adenosine triphosphate (ATP) synthesis. Although various (31)P-MT methods have been successfully used on isolated organs or animals, their application on humans in clinical scanners poses specific challenges. This study compared two major (31)P-MT methods on a clinical MR system using heteronuclear surface coils. Although saturation transfer (ST) is the most commonly used (31)P-MT method, sequences such as inversion transfer (IT) with short pulses might be better suited for the specific hardware and software limitations of a clinical scanner. In addition, small NMR-undetectable metabolite pools can transfer MT to NMR-visible pools during long saturation pulses, which is prevented with short pulses. (31)P-MT sequences were adapted for limited pulse length, for heteronuclear transmit-receive surface coils with inhomogeneous B1 , for the need for volume selection and for the inherently low signal-to-noise ratio (SNR) on a clinical 3-T MR system. The ST and IT sequences were applied to skeletal muscle and liver in 10 healthy volunteers. Monte-Carlo simulations were used to evaluate the behavior of the IT measurements with increasing imperfections. In skeletal muscle of the thigh, ATP synthesis resulted in forward reaction constants (k) of 0.074 ± 0.022 s(-1) (ST) and 0.137 ± 0.042 s(-1) (IT), whereas the creatine kinase reaction yielded 0.459 ± 0.089 s(-1) (IT). In the liver, ATP synthesis resulted in k = 0.267 ± 0.106 s(-1) (ST), whereas the IT experiment yielded no consistent results. ST results were close to literature values; however, the IT results were either much larger than the corresponding ST values and/or were widely scattered. To summarize, ST and IT experiments can both be implemented on a clinical body scanner with heteronuclear transmit-receive surface coils; however, ST results are much more robust against experimental imperfections than the current implementation of IT. Copyright © 2014 John Wiley & Sons, Ltd.
New methods of data calibration for high power-aperture lidar.
Guan, Sai; Yang, Guotao; Chang, Qihai; Cheng, Xuewu; Yang, Yong; Gong, Shaohua; Wang, Jihong
2013-03-25
For high power-aperture lidar sounding of wide atmospheric dynamic ranges, as in middle-upper atmospheric probing, photomultiplier tubes' (PMT) pulse pile-up effects and signal-induced noise (SIN) complicates the extraction of information from lidar return signal, especially from metal layers' fluorescence signal. Pursuit for sophisticated description of metal layers' characteristics at far range (80~130km) with one PMT of high quantum efficiency (QE) and good SNR, contradicts the requirements for signals of wide linear dynamic range (i.e. from approximate 10(2) to 10(8) counts/s). In this article, Substantial improvements on experimental simulation of Lidar signals affected by PMT are reported to evaluate the PMTs' distortions in our High Power-Aperture Sodium LIDAR system. A new method for pile-up calibration is proposed by taking into account PMT and High Speed Data Acquisition Card as an Integrated Black-Box, as well as a new experimental method for identifying and removing SIN from the raw Lidar signals. Contradiction between the limited linear dynamic range of raw signal (55~80km) and requirements for wider acceptable linearity has been effectively solved, without complicating the current lidar system. Validity of these methods was demonstrated by applying calibrated data to retrieve atmospheric parameters (i.e. atmospheric density, temperature and sodium absolutely number density), in comparison with measurements of TIMED satellite and atmosphere model. Good agreements are obtained between results derived from calibrated signal and reference measurements where differences of atmosphere density, temperature are less than 5% in the stratosphere and less than 10K from 30km to mesosphere, respectively. Additionally, approximate 30% changes are shown in sodium concentration at its peak value. By means of the proposed methods to revert the true signal independent of detectors, authors approach a new balance between maintaining the linearity of adequate signal (20-110km) and guaranteeing good SNR (i.e. 10(4):1 around 90km) without debasing QE, in one single detecting channel. For the first time, PMT in photon-counting mode is independently applied to subtract reliable information of atmospheric parameters with wide acceptable linearity over an altitude range from stratosphere up to lower thermosphere (20-110km).
Laboratory Investigations of Bidirectional Reflectance using the Photomultiplier Tube
NASA Astrophysics Data System (ADS)
Vides, C.; Nelson, R. M.; Boryta, M. D.; Manatt, K. S.
2016-12-01
The precise measurement of the intensity of a light source is fundamental data to observational sciences, such as spacecraft imaging and atomic particle detection. Photomultiplier tubes (PMT) have played an integral role in many diverse areas such as spacecraft remote sensing by indicating the physical properties of regolith on a planetary surface and particulate matter in an atmosphere. PMTs are essential in neutrino observatories by detecting Cherenkov radiation, the photons emitted when a neutrino interacts with a dielectric medium at highly relativistic velocities. The PMT utilizes the core principle of Albert Einstein's photoelectric effect, with the aid of secondary emission to multiply the electrons emitted from a primary photon. Traditionally, PMTs are used to measure the intensity of photons reflected from a surface. We designed a photometer such that we could measure the photoelectron current from two Hamamatsu R928 photomultiplier tubes, as amplified by Keithly 610 electrometers. The results provide insight into the behavior of photoelectrons, how temperature affects PMT output current, and the amplification electronics that form a basis for remote sensing measurements. We performed photometry with a maximum error of 1% by measuring the intensity of a coherent light source. The calibration procedure involved incrementing and decrementing the high voltage in steps of 50V on a high voltage power supply to locate the linear range within the Gaussian curve of light intensity as a function of high voltage to maximize the signal to noise. We have measured how the signal to noise ratio changes when transmittance was reduced and compared the performance of the PMTs. We measured the intensity as a function of polarization angle. We then measured the response change of the PMT as the reflectance of the incident surface changed. The data was reduced and analyzed using MATLAB. We corrected aliasing and fit the mathematical function of the photoelectron current in relation to high voltage and polarization. Our results have established the linear range of a photomultiplier tube. We have also shown how the signal to noise ratio increases as light intensity decreases. With these results, we can constrain the limits in which the PMT is a valuable tool for experimentation in the fields of physics and astronomy.
Characterization of Geiger mode avalanche photodiodes for fluorescence decay measurements
NASA Astrophysics Data System (ADS)
Jackson, John C.; Phelan, Don; Morrison, Alan P.; Redfern, R. Michael; Mathewson, Alan
2002-05-01
Geiger mode avalanche photodiodes (APD) can be biased above the breakdown voltage to allow detection of single photons. Because of the increase in quantum efficiency, magnetic field immunity, robustness, longer operating lifetime and reduction in costs, solid-state detectors capable of operating at non-cryogenic temperatures and providing single photon detection capabilities provide attractive alternatives to the photomultiplier tube (PMT). Shallow junction Geiger mode APD detectors provide the ability to manufacture photon detectors and detector arrays with CMOS compatible processing steps and allows the use of novel Silicon-on-Insulator(SoI) technology to provide future integrated sensing solutions. Previous work on Geiger mode APD detectors has focused on increasing the active area of the detector to make it more PMT like, easing the integration of discrete reaction, detection and signal processing into laboratory experimental systems. This discrete model for single photon detection works well for laboratory sized test and measurement equipment, however the move towards microfluidics and systems on a chip requires integrated sensing solutions. As we move towards providing integrated functionality of increasingly nanoscopic sized emissions, small area detectors and detector arrays that can be easily integrated into marketable systems, with sensitive small area single photon counting detectors will be needed. This paper will demonstrate the 2-dimensional and 3-dimensional simulation of optical coupling that occurs in Geiger mode APDs. Fabricated Geiger mode APD detectors optimized for fluorescence decay measurements were characterized and preliminary results show excellent results for their integration into fluorescence decay measurement systems.
Upgraded cameras for the HESS imaging atmospheric Cherenkov telescopes
NASA Astrophysics Data System (ADS)
Giavitto, Gianluca; Ashton, Terry; Balzer, Arnim; Berge, David; Brun, Francois; Chaminade, Thomas; Delagnes, Eric; Fontaine, Gérard; Füßling, Matthias; Giebels, Berrie; Glicenstein, Jean-François; Gräber, Tobias; Hinton, James; Jahnke, Albert; Klepser, Stefan; Kossatz, Marko; Kretzschmann, Axel; Lefranc, Valentin; Leich, Holger; Lüdecke, Hartmut; Lypova, Iryna; Manigot, Pascal; Marandon, Vincent; Moulin, Emmanuel; de Naurois, Mathieu; Nayman, Patrick; Penno, Marek; Ross, Duncan; Salek, David; Schade, Markus; Schwab, Thomas; Simoni, Rachel; Stegmann, Christian; Steppa, Constantin; Thornhill, Julian; Toussnel, François
2016-08-01
The High Energy Stereoscopic System (H.E.S.S.) is an array of five imaging atmospheric Cherenkov telescopes, sensitive to cosmic gamma rays of energies between 30 GeV and several tens of TeV. Four of them started operations in 2003 and their photomultiplier tube (PMT) cameras are currently undergoing a major upgrade, with the goals of improving the overall performance of the array and reducing the failure rate of the ageing systems. With the exception of the 960 PMTs, all components inside the camera have been replaced: these include the readout and trigger electronics, the power, ventilation and pneumatic systems and the control and data acquisition software. New designs and technical solutions have been introduced: the readout makes use of the NECTAr analog memory chip, which samples and stores the PMT signals and was developed for the Cherenkov Telescope Array (CTA). The control of all hardware subsystems is carried out by an FPGA coupled to an embedded ARM computer, a modular design which has proven to be very fast and reliable. The new camera software is based on modern C++ libraries such as Apache Thrift, ØMQ and Protocol buffers, offering very good performance, robustness, flexibility and ease of development. The first camera was upgraded in 2015, the other three cameras are foreseen to follow in fall 2016. We describe the design, the performance, the results of the tests and the lessons learned from the first upgraded H.E.S.S. camera.
Performance study of single undoped CsI crystals for the Mu2e experiment
NASA Astrophysics Data System (ADS)
Donghia, R.; Mu2e Calorimeter Group
2016-03-01
The Mu2e experiment at Fermilab aims to measure the neutrinoless muon-to-electron conversion, which is a charged-lepton flavor-violating process. The goal of the experiment is to reach a single event sensitivity of 2.5 × 10^{-17} , to set an upper limit on the muon conversion rate at 6.7 × 10^{-17} in a three-year run. For this purpose, the Mu2e detector is designed to identify electrons from muon conversion and reduce the background to a negligible level. It consists of a low-mass straw tracker and a pure CsI crystal calorimeter. In this paper, the performance of undoped CsI single crystal is reported. Crystals from many vendors have been characterized by determining their Light Yield (LY) and Longitudinal Response Uniformity (LRU), when read with a UV extended PMT, and their time resolution when coupled to a silicon photomultiplier. The crystals show a LY of ˜100 photoelectrons per MeV when wrapped with Tyvek and coupled to the PMT without optical grease. The LRU is well represented by a linear slope that is on average 0.6%/cm. Both measurements have been performed using a ^{22} Na source. The timing performance has been evaluated exploiting cosmic rays, with MPPC readout. A timing resolution lower than 400ps has been achieved (at ˜20{ MeV} , which is the energy released by a minimum ionizing particle in the crystal).
Gessei, Tomoko; Arakawa, Takahiro; Kudo, Hiroyuki; Mitsubayashi, Kohji
2015-09-21
Accumulation of sorbitol in the tissue is known to cause microvascular diabetic complications. In this paper, a fiber-optic biosensor for sorbitol which is used as a biomarker of diabetic complications was developed and tested. The biosensor used a sorbitol dehydrogenase from microorganisms of the genus Flavimonas with high substrate specificity and detected the fluorescence of reduced nicotinamide adenine dinucleotide (NADH) by the enzymatic reaction. An ultraviolet light emitting diode (UV-LED) was used as the excitation light source of NADH. The fluorescence of NADH was detected using a spectrometer or a photomultiplier tube (PMT). The UV-LED and the photodetector were coupled using a Y-shaped optical fiber. In the experiment, an optical fiber probe with a sorbitol dehydrogenase immobilized membrane was placed in a cuvette filled with a phosphate buffer containing the oxidized form of nicotinamide adenine dinucleotide (NAD(+)). The changes in NADH fluorescence intensity were measured after adding a standard sorbitol solution. According to the experimental assessment, the calibration range of the sorbitol biosensor systems using a spectrometer and a PMT was 5.0-1000 μmol L(-1) and 1.0-1000 μmol L(-1), respectively. The sorbitol biosensor system using the sorbitol dehydrogenase from microorganisms of the genus Flavimonas has high selectivity and sensitivity compared with that from sheep liver. The sorbitol biosensor allows for point-of-care testing applications or daily health care tests for diabetes patients.
Chen, Xinguang; Lunn, Sonya; Deveaux, Lynette; Li, Xioaming; Brathwaite, Nanika; Cottrell, Lesley; Stanton, Bonita
2014-01-01
Background Behavioral interventions based on the Protection Motivation Theory (PMT) have been demonstrated to reduce HIV risk behavior among mid- and older adolescents in different settings across the globe but have not been evaluated among Caribbean nations and have received limited evaluation among pre-adolescents. Objective To determine 1) the effectiveness among pre-adolescents in The Bahamas of a PMT-based HIV prevention program “Focus on Youth in the Caribbean” (FOYC) and 2) the role of the targeted PMT constructs in intervention effect. Methods 1,360 sixth grade youth (10-11 years of age) from 15 urban schools in New Providence, The Bahamas were randomized by school to receive either FOYC or a control condition. Data collected at baseline, six and 12 months post intervention were analyzed. A five-step scheme was used to assess sexual behavior progression, ranging from “1” = “a virgin without intention to have sex” to” 5″ = “having sex without a condom”. Group-based trajectory analysis was utilized in assessing the program effect. Results Two sexual behavior progression patterns were detected: slow progressors and quick progressors. Receiving FOYC reduced the likelihood for adolescents to become quick progressors (adjusted OR = 0.77, 95% CI: 0.64-1.00). The observed effectiveness was especially impacted by a subset of the targeted PMT constructs. Conclusion FOYC effectively delays sexual risk among Bahamian pre-adolescents. The group-based trajectory analysis provides an analytical approach for assessing interventions among adolescents with low rates and diverse progression patterns of sexual activity. PMID:19116781
Högström, Jens; Enebrink, Pia; Melin, Bo; Ghaderi, Ata
2015-08-01
The primary aim of the present study was to evaluate if previously reported treatment gains of a parent management training (PMT) program, administered via Internet, were retained from post to the 18-month follow-up. Another aim was to evaluate homework compliance as a predictor of short and long-term outcomes. Participants were parents of 58 children (3-11 years) with conduct problems who received a 10-week self-directed PMT program, with limited therapist support. Parents of 32 children (55.2 %) responded at all measurement point (baseline, post-test and follow-up) and analyses showed that child conduct problems continued to decrease during the 18-month period after the intervention whereas parenting skills deteriorated somewhat from post treatment. Pre- to post-treatment change in child conduct problems was predicted by parental engagement in homework assignments intended to reduce negative child behaviors. The findings provide support for the use of Internet-based PMT and stress the importance of parental compliance to homework training.
Dehbari, Samaneh Rooshanpour; Dehdari, Tahereh; Dehdari, Laleh; Mahmoudi, Maryam
2015-01-01
Given the importance of sun protection in the prevention of skin cancer, this study was designed to determine predictors of sun-protective practices among a sample of Iranian female college students based on protection motivation theory (PMT) variables. In this cross-sectional study, a total of 201 female college students in Iran University of Medical Sciences were selected. Demographic and PMT variables were assessed with a 67-item questionnaire. Multiple linear regression was used to identify demographic and PMT variables that were associated with sun-protective practices and intention. one percent of participants always wore a hat with a brim, 3.5% gloves and 15.9% sunglasses while outdoors. Only 10.9% regularly had their skin checked by a doctor. Perceived rewards, response efficacy, fear, self-efficacy and marital status were the five variables which could predict 39% variance of participants intention to perform sun-protective practices. Also, intention and response cost explained 31% of the variance of sun-protective practices. These predictive variables may be used to develop theory-based education interventions interventions to prevent skin cancer among college students.
RENU 2 UV Measurements of Atomic Oxygen in the Cusp Region
NASA Astrophysics Data System (ADS)
Fritz, B.; Lessard, M.; Paxton, L. J.; Cook, T.; Lynch, K. A.; Clemmons, J. H.; Hecht, J. H.; Hysell, D. L.; Crowley, G.
2016-12-01
The RENU 2 NASA sounding rocket mission launched from the Andoya Space Center on 13 December, 2015 into the dayside cusp region. A UV Photometer (UV PMT) provided by the University of New Hampshire was oriented to look up along the local magnetic field line as the payload passed through a poleward moving auroral form (PMAF). The bandpass filter on the UV PMT isolated emissions of atomic oxygen at both 130.4 nm and 135.6 nm. The instrument measured a clear enhancement in the topside ionosphere as the payload descended through a region of soft electron precipitation. The RENU 2 UV PMT was flown uncalibrated but measured a clear signal with both a major overall structure as well as several smaller peaks of fine structure. An identical spare has been built and calibrated using a Paresce UV light source at UMass-Lowell to compare and correlate with the flight data. An approximation of the flight data luminosity from the spare instrument and other flight data from RENU 2 is used in a radiative transport model to infer structure of upwelling neutral atomic oxygen above the PMAF.
Higley, Meghan; Beckett, Brooke; Schmahmann, Sandra; Dacey, Elizabeth; Foss, Erik
2015-12-01
Tumor-induced osteomalacia (TIO) has long been recognized as a clinical paraneoplastic syndrome. The identification of a unique histopathologic entity, the phosphaturic mesenchymal tumor (PMT), as a distinct etiology for TIO has been a more recent discovery. The majority of published cases describe a solitary, non-aggressive appearing soft tissue or osseous lesions in patients with osteomalacia; aggressive appearing or multifocal lesions appear to be exceedingly rare. These tumors characteristically secrete fibroblast growth factor 23 (FGF23). Elevated serum levels of FGF23 result in phosphate wasting and osteomalacia. In the majority of cases, laboratory abnormalities and clinical signs and symptoms of osteomalacia precede identification of the causative lesion by years. Following diagnosis, complete resection with wide margins to prevent local recurrence is most often curative. Imaging characteristics of PMT are diverse and remain incompletely defined, as the majority of previous publications are outside of the radiologic literature. We present multiple imaging modalities in two cases of patients with debilitating osteomalacia and unusual appearing PMTs: one with a locally aggressive lesion leading to pathologic fracture, the second presenting with exceedingly rare multifocal PMT.
Wang, Lei; Lian, Wenjing; Liu, Hongyun
2016-03-24
A closed bipolar electrode (BPE) system was developed with electrochromic poly(3-methylthiophene) (PMT) films electropolymerized on the ITO/rGO electrode as one pole of BPE in the reporting reservoir and the bare ITO electrode as another pole of BPE in the analyte reservoir, in which rGO represents reduced graphene oxide. Under a suitable driving voltage (Vtot), the electrochemical reduction/oxidation of electroactive probes, such as H2O2/glutathione (Glu), in the analyte reservoir could induce the reversible color change of PMT films in the reporting reservoir between blue and red. Based on this, a keypad lock with H2O2 , Glu, and Vtot =-3.0 V as the three inputs and the color change of PMT films as the visible output was established. This system was easily operated and did not need to synthesize the complex compounds or DNA molecules. The security system was easy to reset and could be used repeatedly. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Ali, Anwar; Mughal, M. Rizwan; Ali, Haider; Reyneri, Leonardo
2014-03-01
Electric power supply (EPS) and attitude determination and control subsystem (ADCS) are the most essential elements of any aerospace mission. Efficient EPS and precise ADCS are the core of any spacecraft mission. So keeping in mind their importance, they have been integrated and developed on a single tile called CubePMT module. Modular power management tiles (PMTs) are already available in the market but they are less efficient, heavier in weight, consume more power and contain less number of subsystems. Commercial of the shelf (COTS) components have been used for CubePMT implementation which are low cost and easily available from the market. CubePMT is developed on the design approach of AraMiS architecture: a project developed at Politecnico di Torino that provides low cost and higher performance space missions with dimensions larger than CubeSats. The feature of AraMiS design approach is its modularity. These modules can be reused for multiple missions which helps in significant reduction of the overall budget, development and testing time. One has just to reassemble the required subsystems to achieve the targeted specific mission.
NASA Astrophysics Data System (ADS)
Hara, K. Y.; Harada, H.; Toh, Y.; Hori, J.
2013-09-01
A gated photomultiplier tube (PMT) assembled with an LaBr3(Ce) detector was applied toward the prompt γ{hbox-}ray measurement of fast neutron capture reactions. Time-of-flight measurements of the neutron capture reactions of Cl and Al were performed using the 46-MeV electron linear accelerator at the Kyoto University Research Reactor Institute (KURRI) as a pulsed neutron source. The photomultiplier gating technique effectively suppressed the saturation of the PMT output and extended the energy region of the TOF measurement.
Protection motivation theory and stages of change in sun protective behavior.
Prentice-Dunn, Steven; McMath, Ben F; Cramer, Robert J
2009-03-01
This study examined the usefulness of the stage of change model and protection motivation theory (PMT) in creating brief persuasive appeals to promote healthy sun-behavior. College women (N = 254) read one of four essays that manipulated the level of threat and coping appraisal. The transition from the precontemplation to contemplation stage was promoted by threat appraisal information, but transition from contemplation to the preparation stage occurred only when individuals were provided with both high threat and high coping information. Thus, brief communications based on PMT may create attitudes leading to behavior change when later, more intensive, interventions are introduced.
Characterization of Novel Operation Modes for Secondary Emission Ionization Calorimetry
NASA Astrophysics Data System (ADS)
Tiras, Emrah; Dilsiz, Kamuran; Ogul, Hasan; Snyder, Christina; Bilki, Burak; Onel, Yasar; Winn, David
2017-01-01
Secondary Emission (SE) Ionization Calorimetry is a novel technique to measure electromagnetic showers in high radiation environments. We have developed new operation modes by modifying the bias of the conventional PMT circuits. Hamamatsu single anode R7761 and multi-anode R5900-00-M16 Photomultiplier Tubes (PMTs) with modified bases are used as SE detector modules in our SE calorimetry prototype. In this detector module, the first dynode is used as the active media as opposed to photocathode. Here, we report the technical design of new modes and characterization measurements for both SE and PMT modes.
Lwin, May O; Vijaykumar, Santosh; Foo, Schubert; Fernando, Owen Noel Newton; Lim, Gentatsu; Panchapakesan, Chitra; Wimalaratne, Prasad
2016-02-01
This article focuses on a novel social media-based system that addresses dengue prevention through an integration of three components: predictive surveillance, civic engagement and health education. The aim was to conduct a potential receptivity assessment of this system among smartphone users in the city of Colombo, the epicenter of the dengue epidemic in the island country of Sri Lanka. Grounded in Protection Motivation Theory (PMT) and using a convenience sampling approach, the cross-sectional survey assessed perceived severity (PSe), perceived susceptibility (PSu), perceived response efficacy (PRE), perceived self-efficacy (PSE) and intention-to-use (IU) among 513 individuals. The overall receptivity to the system was high with a score of >4.00 on a five-point scale. Participants belonging to younger, better educated and higher income groups reported significantly better perceptions of the efficaciousness of the system, were confident in their ability to use the system, and planned to use it in the future. PMT variables contributed significantly to regression models predicting IU. We concluded that a social media-based system for dengue prevention will be positively received among Colombo residents and a targeted, strategic health communication effort to raise dengue-related threat perceptions will be needed to encourage greater adoption and use of the system. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.
De Sutter, Valerie; Vanderhaeghen, Rudy; Tilleman, Sofie; Lammertyn, Freya; Vanhoutte, Isabelle; Karimi, Mansour; Inzé, Dirk; Goossens, Alain; Hilson, Pierre
2005-12-01
Although sequence information and genome annotation are improving at an impressive pace, functional ontology is still non-existent or rudimentary for most genes. In this regard, transient expression assays are very valuable for identification of short functional segments in particular pathways, because they can be performed rapidly and at a scale unattainable in stably transformed tissues. Vectors were constructed and protocols developed for systematic transient assays in plant protoplasts. To enhance throughput and reproducibility, protoplast treatments were performed entirely by a liquid-handling robot in multiwell plates, including polyethylene glycol/Ca2+ cell transfection with plasmid mixtures, washes and lysis. All transcriptional readouts were measured using a dual firefly/Renilla luciferase assay, in which the former was controlled by a reporter promoter and the latter by the 35S CaMV promoter, which served as internal normalization standard. The automated protocols were suitable for transient assays in protoplasts prepared from cell cultures of Nicotiana tabacum Bright Yellow-2 and Arabidopsis thaliana. They were implemented in a screen to discover potential regulators of genes coding for key enzymes in nicotine biosynthesis. Two novel tobacco transcription factors were found, NtORC1 and NtJAP1, that positively regulate the putrescine N-methyltransferase (PMT) promoter. In addition, combinatorial tests showed that these two factors act synergistically to induce PMT transcriptional activity. The development and use of high-throughput plant transient expression assays are discussed.
The ionoluminescence apparatus at the LABEC external microbeam facility
NASA Astrophysics Data System (ADS)
Calusi, S.; Colombo, E.; Giuntini, L.; Giudice, A. Lo; Manfredotti, C.; Massi, M.; Pratesi, G.; Vittone, E.
2008-05-01
In this paper, we describe the main features of the ionoluminescence (IL) apparatus recently installed at the external scanning microbeam facility of the 3 MV Tandetron accelerator of the INFN LABEC Laboratory in Firenze. The peculiarity of this IL set-up resides in the fact that the light produced by the ion irradiation of the specimen is collected by a bifurcated optical fiber, so that photons are shunted both to a CCD spectrometer, working in the 200-900 nm wavelength range, and to a photomultiplier (PMT). The accurate focusing of the optical system allows high photon collection efficiency and this results in rapid acquisition of luminescence spectra with low ion currents on luminescent materials; simultaneously, luminescence maps with a spatial resolution of 10 μm can be acquired through the synchronization of PMT photon detection with the position of the scanning focused ion beam. An optical filter with a narrow passband facing the photomultiplier allows chromatic selectivity of the luminescence centres. The IL apparatus is synergistically integrated into the existing set-up for ion beam analyses (IBA). The upgraded system permits simultaneous IL and PIXE/PIGE/BS measurements. With our integrated system, we have been studying raw lapis lazuli samples of different known origins and precious lapis lazuli artworks of the Collezione Medicea of Museum of Natural History, University of Firenze, aiming at characterising their composition and provenance.
2010-01-01
Background Recently introduced regulatory changes have expanded the Tutor role to include their primary responsibility for Postgraduate Medical Training (PMT). However, accreditation and recognition of that role has been devolved to the autonomic regions. The opinions of the RT may be relevant to future decisions; Methods A comprehensive questionnaire, including demographic characteristics, academic and research achievement and personal views about their role, was sent to 201 RTs in the Murcia Region of Spain. The responses are described using median and interquartile ranges (IQR); Results There were 147 replies (response rate 73%), 69% male, mean age 45 ± 7 yrs. RTs perception of the residents' initial knowledge and commitment throughout the program was 5 (IQR 4-6) and 7 (IQR 5-8), respectively. As regards their impact on the PMT program, RTs considered that their own contribution was similar to that of senior residents. RTs perception of how their role was recognised was 5 (IQR 3-6). Only 16% did not encounter difficulties in accessing specific RT training programs. Regarding the RTs view of their various duties, supervision of patient care was accorded the greatest importance (64%) while the satisfactory completion of the PMT program and supervision of day-to-day activities were also considered important (61% and 59% respectively). The main RT requirements were: a greater professional recognition (97%), protected time (95%), specific RT training programs (95%) and financial recognition (86%); Conclusions This comprehensive study, reflecting the feelings of our RTs, provides a useful insight into the reality of their work and the findings ought to be taken into consideration in the imminent definitive regulatory document on PMT. PMID:20540814
Streit, Jonathan J; Lenarz, Christopher J; Shishani, Yousef; McCrum, Christopher; Wanner, J P; Nowinski, R J; Warner, Jon J P; Gobezie, Reuben
2012-05-01
Painful scapular winging due to chronic long thoracic nerve (LTN) palsy is a relatively rare disorder that can be difficult to treat. Pectoralis major tendon (PMT) transfer has been shown to be effective in relieving pain, improving cosmesis, and restoring function. However, the available body of literature consists of few, small-cohort studies, and more outcomes data are needed. Outcomes of 26 consecutive patients with electromyelogram-confirmed LTN palsy who underwent direct (n = 4) or indirect transfer (n = 22) of the PMT for dynamic stabilization of the scapula were reviewed. All patients were followed up clinically for an average of 21.8 months (range, 3-62 months) with evaluations of active forward flexion, active external rotation, American Shoulder and Elbow Surgeons (ASES) score, visual analog scale (VAS) pain score, and observation of scapular winging. Preoperative to postoperative results included increases in the mean active forward flexion from 112° to 149° (P < .001) an in mean active external rotation from 53.8° to 62.8° (P = .045), an improvement in the mean ASES score from 28 to 67.0 (P < .001), and an improvement in the mean VAS pain score from 7.7 to 3.0 (P < .001). Recurrent scapular winging occurred in 5 patients. There was no difference in outcome by length of follow-up. PMT transfer is an effective treatment for painful scapular winging resulting from LTN palsy. This is the largest reported series of consecutive patients treated with PMT transfer for the correction of scapular winging. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Chen, Lichao; McKenna, James T.; Bolortuya, Yunren; Brown, Ritchie E.
2012-01-01
Dysfunction of the orexin/hypocretin neurotransmitter system causes the sleep disorder narcolepsy, characterized by intrusion of rapid-eye-movement (REM) sleep-like events into normal wakefulness. The sites where orexins act to suppress REM sleep are incompletely understood. Previous studies suggested that the lateral pontomesencephalic tegmentum (lPMT) contains an important REM sleep inhibitory area, and proposed that orexins inhibit REM sleep via orexin type 2 receptors (OxR2) in this region. However, this hypothesis has heretofore not been tested. We thus performed bilateral injection of small interfering RNAs (siRNAs) targeting Ox2R into the lPMT on two consecutive days. This led to a ~30 % increase of time spent in REM sleep in both the dark and light periods for the first two days after injection, with a return to baseline over the next two post-injection days. This increase was mainly due to more longer (>120 s) REM episodes. Cataplexy-like episodes were not observed. The percentage of time spent in wakefulness and NREM sleep, as well as the power spectral profile of NREM and REM sleep, were unaffected. Control animals injected with scrambled siRNA had no sleep changes post-injection. Quantification of the knockdown revealed that unilateral microinjection of siRNAs targeting OxR2 into the lPMT induced a ~40% reduction of OxR2 mRNA two days following the injections when compared to the contralateral side receiving control (scrambled) siRNA. Orexin type 1 receptor (OxR1) mRNA level was unaffected. Our results indicate that removal of OxR2 neurotransmission in the lPMT enhances REM sleep by increasing the duration of REM episodes. PMID:23282008
Xu, Yunan; Chen, Xinguang
2016-01-01
Tobacco use is one of the greatest public health problems worldwide and the hazards of cigarette smoking to public health call for better recognition of cigarette smoking behaviors to guide evidence-based policy. Protection motivation theory (PMT) provides a conceptual framework to investigate tobacco use. Evidence from diverse sources implies that the dynamics of smoking behavior may be quantum in nature, consisting of an intuition and an analytical process, challenging the traditional linear continuous analytical approach. In this study, we used cusp catastrophe, a nonlinear analytical approach to test the dual-process hypothesis of cigarette smoking. Data were collected from a random sample of vocational high school students in China ( n = 528). The multivariate stochastic cusp modeling was used and executed with the Cusp Package in R. The PMT-based Threat Appraisal and Coping Appraisal were used as the two control variables and the frequency of cigarette smoking (daily, weekly, occasional, and never) in the past month was used as the outcome variable. Consistent with PMT, the Threat Appraisal (asymmetry, α 1 = 0.1987, p < 0.001) and Coping Appraisal (bifurcation, β 2 = 0.1760, p < 0.05) significantly predicted the smoking behavior after controlling for covariates. Furthermore, the cusp model performed better than the alternative linear and logistic regression models with regard to higher R 2 (0.82 for cusp, but 0.21 for linear and 0.25 for logistic) and smaller AIC and BIC. Study findings support the conclusion that cigarette smoking in adolescents is a quantum process and PMT is relevant to guide studies to understand smoking behavior for smoking prevention and cessation.
NASA Astrophysics Data System (ADS)
Toyama, T.; Hanabata, Y.; Hose, J.; Menzel, U.; Mirzoyan, R.; Nakajima, D.; Takahashi, M.; Teshima, M.; Yamamoto, T.
2015-07-01
Currently the standard light sensors for Imaging Atmospheric Cherenkov Telescopes are the classical photo multiplier tubes that are using bialkali photocathodes. About 8 years ago we initiated an improvement program with the Photo Multiplier Tube manufacturers Hamamatsu in Japan, Electron Tubes Enterprises in England and Photonis in France for the needs of Imaging Atmospheric Cherenkov Telescopes. As a result, after about 40 years of "stagnation" of the peak Quantum Efficiency on the level of 25-27%, new PMTs appeared with a peak QE of 35%. These have got the name "super-bialkali". The second significant upgrade has happened very recently, as a result of a dedicated improvement program for the candidate PMT for Cherenkov Telescope Array. The latter is going to be the next generation major instrument in the field of very high energy gamma astrophysics and will consist of over 100 telescopes of three different sizes of 23 m, 12 m and 4-7 m. Now PMTs with average peak Quantum Efficiency of approximately 40% became available. Also, the photo electron collection efficiency of the previous generation PMTs of 80-90% has been enhanced towards 95-98% for the new ones. The after-pulsing of novel PMTs has been reduced towards the level of 0.02% for the set threshold of 4 photo electrons. Hamamatsu produced the PMT R-12992-100 as the final version for Cherenkov Telescope Array project. Electron Tubes produced the latest PMT D569/3SA as intermediate version and will produce the final version in 2015. We will report on the PMT development work by the companies Electron Tubes Enterprises and Hamamatsu Photonics K.K., show the achieved results and the current status.
Quattrochi, James J.; Bazalakova, Mihaela; Hobson, J. Allan
2006-01-01
It is not known how the brain modifies its regulatory systems in response to the application of a drug, especially over the long term of weeks and months. We have developed a model system approach to this question by manipulating cholinergic cell groups of the laterodorsal and pedunculopontine tegmental (LDT/PPT) nuclei in the pontomesencephalic tegmentum (PMT), which are known to be actively involved in the timing and quantity of rapid eye movement (REM) sleep. In a freely moving feline model, a single microinjection of the cholinergic agonist carbachol conjugated to a latex nanosphere delivery system into the caudolateral PMT elicits a long-term enhancement of one distinguishing phasic event of REM sleep, ponto-geniculo-occipital (PGO) waves, lasting 5 days but without any significant change in REM sleep or other behavioral state. Here, we test the hypothesis that cholinergic activation within the caudolateral PMT alters the postsynaptic excitability of the PGO network, stimulating the prolonged expression of c-fos that underlies this long-term PGO enhancement (LTPE) effect. Using quantitative Fos immunohistochemistry, we found that the number of Fos-immunoreactive (Fos-IR) neurons surrounding the caudolateral PMT injection site decreased sharply by postcarbachol day 03, while the number of Fos-IR neurons in the more rostral LDT/PPT increased >30-fold and remained at a high level following the course of LTPE. These results demonstrate a sustained c-fos expression in response to pharmacological stimulation of the brain and suggest that carbachol's acute effects induce LTPE via cholinergic receptors, with subsequent transsynaptic activation of the LDT/PPT maintaining the LTPE effect. PMID:15893601
NASA Astrophysics Data System (ADS)
Dongol, R.; Sundaram, S. K.
2017-09-01
The addition of Gadolinium (Gd)-based salt, specially GdCl3, in the Water Cherenkov Detectors (WCDs) enhances the sensitivity to neutrino detection. However, the unwanted Cl-based byproducts, significantly reduces the transparency of water and sensitivity of WCDs. An alternative method, to introduce Gd-ions in the WCDs, is through Gd-release from a custom designed Gd-doped glass, when in contact with water. This can potentially eliminate the use of Gd-based salts and byproducts. In this work, we report the Gd-ions release for a Gd-doped peralkaline (Na/Al > 1) borosilicate glass, which closely represents photomultiplier tube (PMT) glass composition used in WCDs. The purpose of the paper is to show that the Gd-ion release from a custom designed glass in the form of beads or powders is feasible and could be used as a controlled Gd-source in future WCDs to enhance neutrino detection. In addition, we present our results of Gd-solubility in the base glass composition.
MacInnes, Janet I.; Gottschalk, Marcelo; Lone, Abdul G.; Metcalf, Devon S.; Ojha, Shivani; Rosendal, Thomas; Watson, Sheila B.; Friendship, Robert M.
2008-01-01
Tonsillar and nasal swabs were collected from weanling pigs in 50 representative Ontario swine herds and tested for the presence of 5 important bacterial upper respiratory tract pathogens. All but 1 herd (2%) tested positive for Streptococcus suis by polymerase chain reaction (PCR); 48% of herds were S. suis serovar 2, 1/2 positive. In all but 2 herds there was evidence of Haemophilus parasuis infection. In contrast, toxigenic strains of Pasteurella multocida were detected by a P. multocida — enzyme-linked immunosorbant assay (PMT-ELISA) in only one herd. Seventy-eight percent of the herds were diagnosed positive for Actinobacillus pleuropneumoniae by apxIV PCR. Sera from finishing pigs on the same farms were also collected and tested by ELISA for the presence of A. pleuropneumoniae antibodies. Seventy percent of the herds tested had evidence of antibodies to A. pleuropneumoniae including serovars 1–9–11 (2%), 2 (4%), 3–6–8–15 (15%), 5 (6%), 4–7 (26%), and 12 (17%). This likely represents a shift from previous years when infection with A. pleuropneumoniae serovars 1, 5, and 7 predominated. At least 16% and possibly as many as 94% of the herds tested were Actinobacillus suis positive; only 3 of the 50 herds were both A. pleuropneumoniae and A. suis negative as judged by the absence of a positive PCR test for apxII. Taken together, these data suggest that over the past 10 years, there has been a shift in the presence of pathogenic bacteria carried by healthy Ontario swine with the virtual elimination of toxigenic strains of P. multocida and a move to less virulent A. pleuropneumoniae serovars. As well, there appears to be an increase in prevalence of S. suis serovar 2, 1/2, but this may be a reflection of the use of a more sensitive detection method. PMID:18505187
Targeting the Poor: Evidence from a Field Experiment in Indonesia
Alatas, Vivi; Banerjee, Abhijit; Hanna, Rema; Olken, Benjamin A.; Tobias, Julia
2014-01-01
This paper reports an experiment in 640 Indonesian villages on three approaches to target the poor: proxy-means tests (PMT), where assets are used to predict consumption; community targeting, where villagers rank everyone from richest to poorest; and a hybrid. Defining poverty based on PPP$2 per-capita consumption, community targeting and the hybrid perform somewhat worse in identifying the poor than PMT, though not by enough to significantly affect poverty outcomes for a typical program. Elite capture does not explain these results. Instead, communities appear to apply a different concept of poverty. Consistent with this finding, community targeting results in higher satisfaction. PMID:25197099
Photomultiplier tube failure under hydrostatic pressure in future neutrino detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chambliss, K.; Diwan, M.; Simos, N.
Failure of photomultiplier tubes (PMTs) under hydrostatic pressure is a concern in neutrino detection, specifically, in the proposed Long-Baseline Neutrino Experiment project. Controlled hydrostatic implosion tests were performed on prototypic PMT bulbs of 10-inch diameter and recorded using high speed filming techniques to capture failures in detail. These high-speed videos were analyzed frame-by-frame in order to identify the origin of a crack, measure the progression of individual crack along the surface of the bulb as it propagates through the glass, and estimate crack velocity. Crack velocity was calculated for each individual crack, and an average velocity was determined for allmore » measurable cracks on each bulb. Overall, 32 cracks were measured in 9 different bulbs tested. Finite element modeling (FEM) of crack formation and growth in prototypic PMT shows stress concentration near the middle section of the PMT bulbs that correlates well with our crack velocity measurements in that section. The FEM model predicts a crack velocity value that is close to the terminal crack velocity reported. Our measurements also reveal significantly reduced crack velocities compared to terminal crack velocities measured in glasses using fracture mechanics testing and reported in literature.« less
Dehdari, Tahereh; Hassani, Laleh; Hajizadeh, Ebrahim; Shojaeizadeh, Davoud; Nedjat, Saharnaz; Abedini, Mehrandokht
2014-01-01
Few Iranian women take the Papanicolaou test despite its important role in preventing cervical cancer. This study aimed to determine the effectiveness of an educational intervention based on the protection motivation theory (PMT) variables and implementation intentions in the first and second Pap test practice among Iranian women. In this quasi-randomized controlled trial, 200 women who were referred to 30 primary health care clinics in Tehran were randomly selected. PMT variables and Pap test practice were measured at baseline and again after 3 and 15 months. The 4-week educational intervention program was conducted for the intervention group. Following the intervention, the mean scores of self-efficacy, perceived vulnerability, and behavior intention variables were significantly higher in the intervention group when compared to the control group (p<0.05). No significant differences were found in the perceived severity, response efficacy, response cost, and fear between the two groups following the intervention. Higher percent of women in the intervention group had obtained first and second Pap test compared to the controls. The PMT and implementation intentions provide a suitable theory-based framework for developing educational interventions regarding Pap test practice in Iran.
Milne, Sarah; Orbell, Sheina; Sheeran, Paschal
2002-05-01
This study compared a motivational intervention based on protection motivation theory (PMT, Rogers, 1975, 1983) with the same motivational intervention augmented by a volitional intervention based on implementation intentions (Gollwitzer, 1993). The study had a longitudinal design, involving three waves of data collection over a 2-week period, incorporating an experimental manipulation of PMT variables at Time 1 and a volitional, implementation intention intervention at Time 2. Participants (N=248) were randomly allocated to a control group or one of two intervention groups. Cognitions and exercise behaviour were measured at three time-points over a 2-week period. The motivational intervention significantly increased threat and coping appraisal and intentions to engage in exercise but did not bring about a significant increase in subsequent exercise behaviour. In contrast, the combined protection motivation theory/implementation intention intervention had a dramatic effect on subsequent exercise behaviour. This volitional intervention did not influence behavioural intention or any other motivational variables. It is concluded that supplementing PMT with implementation intentions strengthens the ability of the model to explain behaviour. This has implications for health education programmes, which should aim to increase both participants' motivation and their volition.
Photomultiplier tube failure under hydrostatic pressure in future neutrino detectors
Chambliss, K.; Diwan, M.; Simos, N.; ...
2014-10-09
Failure of photomultiplier tubes (PMTs) under hydrostatic pressure is a concern in neutrino detection, specifically, in the proposed Long-Baseline Neutrino Experiment project. Controlled hydrostatic implosion tests were performed on prototypic PMT bulbs of 10-inch diameter and recorded using high speed filming techniques to capture failures in detail. These high-speed videos were analyzed frame-by-frame in order to identify the origin of a crack, measure the progression of individual crack along the surface of the bulb as it propagates through the glass, and estimate crack velocity. Crack velocity was calculated for each individual crack, and an average velocity was determined for allmore » measurable cracks on each bulb. Overall, 32 cracks were measured in 9 different bulbs tested. Finite element modeling (FEM) of crack formation and growth in prototypic PMT shows stress concentration near the middle section of the PMT bulbs that correlates well with our crack velocity measurements in that section. The FEM model predicts a crack velocity value that is close to the terminal crack velocity reported. Our measurements also reveal significantly reduced crack velocities compared to terminal crack velocities measured in glasses using fracture mechanics testing and reported in literature.« less
The central pixel of the MAGIC telescope for optical observations
NASA Astrophysics Data System (ADS)
Lucarelli, F.; Barrio, J. A.; Antoranz, P.; Asensio, M.; Camara, M.; Contreras, J. L.; Fonseca, M. V.; Lopez, M.; Miranda, J. M.; Oya, I.; Reyes, R. De Los; Firpo, R.; Sidro, N.; Goebel, F.; Lorenz, E.; Otte, N.
2008-05-01
The MAGIC telescope has been designed for the observation of Cherenkov light generated in Extensive Air Showers initiated by cosmic particles. However, its 17 m diameter mirror and optical design makes the telescope suitable for direct optical observations as well. In this paper, we report about the development of a system based on the use of a dedicated photo-multiplier (PMT) for optical observations. This PMT is installed in the centre of the MAGIC camera (the so-called central pixel). An electro-to-optical system has been developed in order to transmit the PMT output signal by an optical fibre to the counting room, where it is digitized and stored for off-line analysis. The performance of the system using the optical pulsation of the Crab nebula as calibration source is presented. The time required for a 5σ detection of the Crab pulsar in the optical band is less than 20 s. The central pixel will be mainly used to perform simultaneous observations of the Crab pulsar both in the optical and γ-ray regimes. It will also allow for periodic testing of the precision of the MAGIC timing system using the Crab rotational optical pulses as a very precise timing reference.
Ralph, Angelique F; Ager, Brittany; Bell, Melanie L; Collins, Ian M; Andrews, Lesley; Tucker, Kathy; Phillips, Kelly-Anne; Butow, Phyllis
2014-07-01
Selective estrogen receptor modulators (SERMs) reduce breast cancer risk by 38%. However, uptake is low and the reasons are not well understood. This study applied protection motivation theory (PMT) to determine factors associated with intention to take SERMs. Women at increased risk of breast cancer (N=107), recruited from two familial cancer clinics in Australia, completed a questionnaire containing measures of PMT constructs. Hierarchical multiple linear regression analysis was used to analyze the data. Forty-five percent of women said they would be likely or very likely to take SERMs in the future. PMT components accounted for 40% of variance in intention to take SERMs. Perceived vulnerability, severity and response efficacy appeared the most influential in women's decisions to take or not take SERMs. Many women are interested in SERMs as a risk management option. Accurate risk estimation and an understanding of the benefits of SERMs are critical to women's decision making. Health professionals need to explore women's perceptions of their risk and its consequences, as well as providing clear evidence-based information about the efficacy of SERMs. Exploring the source and strength of beliefs about SERMs may allow more effective, tailored counseling. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Tesson, Stephanie; Richards, Imogen; Porter, David; Phillips, Kelly-Anne; Rankin, Nicole; Musiello, Toni; Marven, Michelle; Butow, Phyllis
2016-05-01
Most women diagnosed with unilateral breast cancer without BRCA1 or BRCA2 mutations are at low risk of contralateral breast cancer. Contralateral Prophylactic Mastectomy (CPM) decreases the relative risk of contralateral breast cancer, but may not increase life expectancy; yet international uptake is increasing. This study applied protection motivation theory (PMT) to determine factors associated with women's intentions to undergo CPM. Three hundred eighty-eight women previously diagnosed with unilateral breast cancer and of negative or unknown BRCA1 or BRCA2 status were recruited from an advocacy group's research database. Participants completed measures of PMT constructs based on a common hypothetical CPM decision-making scenario. PMT constructs explained 16% of variance in intentions to undergo CPM. Response efficacy (CPM's advantages) and response costs (CPM's disadvantages) were unique individual predictors of intentions. Decision-making appears driven by considerations of the psychological, cosmetic and emotional advantages and disadvantages of CPM. Overestimations of threat to life from contralateral breast cancer and survival benefit from CPM also appear influential factors. Patients require balanced and medically accurate information regarding the pros and cons of CPM, survival rates, and recurrence risks to ensure realistic and informed decision-making.
A liquid xenon imaging telescope for 1-30 MeV gamma-ray astrophysics
NASA Technical Reports Server (NTRS)
Aprile, Elena; Mukherjee, Reshmi; Suzuki, Masayo
1989-01-01
A study of the primary scintillation light in liquid xenon excited by 241 Am alpha particles and 207 Bi internal conversion electrons are discussed. The time dependence and the intensity of the light at different field strengths have been measured with a specifically designed chamber, equipped with a CaF sub 2 light transmitting window coupled to a UV sensitive PMT. The time correlation between the fast light signal and the charge signal shows that the scintillation signals produced in liquid xenon by ionizing particles provides an ideal trigger in a Time Projection type LXe detector aiming at full imaging of complex gamma-ray events. Researchers also started Monte Carlo calculations to establish the performance of a LXe imaging telescope for high energy gamma-rays.
Rayleigh Scattering Diagnostic for Simultaneous Measurements of Dynamic Density and Velocity
NASA Technical Reports Server (NTRS)
Seasholtz, Richard G.; Panda, J.
2000-01-01
A flow diagnostic technique based on the molecular Rayleigh scattering of laser light is used to obtain dynamic density and velocity data in turbulent flows. The technique is based on analyzing the Rayleigh scattered light with a Fabry-Perot interferometer and recording information about the interference pattern with a multiple anode photomultiplier tube (PMT). An artificial neural network is used to process the signals from the PMT to recover the velocity time history, which is then used to calculate the velocity power spectrum. The technique is illustrated using simulated data. The results of an experiment to measure the velocity power spectrum in a low speed (100 rn/sec) flow are also presented.
Portable biochip scanner device
Perov, Alexander; Sharonov, Alexei; Mirzabekov, Andrei D.
2002-01-01
A portable biochip scanner device used to detect and acquire fluorescence signal data from biological microchips (biochips) is provided. The portable biochip scanner device employs a laser for emitting an excitation beam. An optical fiber delivers the laser beam to a portable biochip scanner. A lens collimates the laser beam, the collimated laser beam is deflected by a dichroic mirror and focused by an objective lens onto a biochip. The fluorescence light from the biochip is collected and collimated by the objective lens. The fluorescence light is delivered to a photomultiplier tube (PMT) via an emission filter and a focusing lens. The focusing lens focuses the fluorescence light into a pinhole. A signal output of the PMT is processed and displayed.
Chen, Ze-yong; Peng, Rong-fei; Zhang, Zhan-xia
2002-06-01
An atomic emission spectrometer based on acousto-optic tunable filter (AOTF) was self-constructed and was used to evaluate its practical use in atomic emission analysis. The AOTF used was of model TEAF5-0.36-0.52-S (Brimrose, USA) and the frequency of the direct digital RF synthesizer ranges from 100 MHz to 200 MHz. ICP and PMT were used as light source and detector respectively. The software, written in Visual C++ and running on the Windows 98 platform, is of an utility program system having two data banks and multiwindows. The wavelength calibration was performed with 14 emission lines of Ca, Y, Li, Eu, Sr and Ba using a tenth-order polynomial for line fitting method. The absolute error of the peak position was less than 0.1 nm, and the peak deviation was only 0.04 nm as the PMT varied from 337.5 V to 412.5 V. The scanning emission spectra and the calibration curves of Ba, Y, Eu, Sc and Sr are presented. Their average correlation coefficient was 0.9991 and their detection limits were in the range of 0.051 to 0.97 micrograms.mL-1 respectively. The detection limit can be improved under optimized operating conditions. However, the spectral resolution is only 2.1 nm at the wavelength of 488 nm. Evidently, this poor spectral resolution would restrict the application of AOTF in atomic emission spectral analysis, unless an enhancing techniques is integrated in it.
A Central Positron Source to Perform the Timing Alignment of Detectors in a PET Scanner
NASA Astrophysics Data System (ADS)
Thompson, C. J.; Camborde, M.-L.; Casey, M. E.
2005-10-01
Accurate timing alignment and stability are important to maximize the true counts and minimize the random counts in positron emission tomography. Its importance increases in time-of-flight (TOF) scanners. We propose using a central positron emitting source enclosed in a detector which detects the excess energy of the positron before it annihilates as a timing reference. All crystals can be time-aligned with respect to this central source. We evaluated 10 /spl mu/Ci /sup 22/Na and /sup 68/Ge sources embedded in cylinders of plastic scintillator coupled to a fast PMT. Light flashes produced after the parent isotope emits positrons are detected, and the anode signals from the PMT are the reference time for each positron decay. The time delay before the gamma ray is detected by the scanner's conventional gamma ray detectors is the time offset to be applied to that crystal. Since all detectors are almost the same distance from the central source, TOF errors are minimized. Preliminary results show a mean signal amplitude of >0.5 V from /sup 22/Na at 1000-V PMT bias, a timing FWHM of 850 ps with respect to a small LSO crystal. This suggests it could be useful to align both conventional and TOF PET scanners.
Energy requirements of US Army Special Operation Forces during military training.
Margolis, Lee M; Crombie, Aaron P; McClung, Holly L; McGraw, Susan M; Rood, Jennifer C; Montain, Scott J; Young, Andrew J
2014-05-12
Special Operations Forces (SOF) regularly engage in physically demanding combat operations and field training exercises, resulting in high daily energy expenditure, and thus increased energy requirements. However, the majority of studies assessing energy requirements of SOF have been conducted on soldiers going through intense SOF initiation training. The objective of the current investigation was to determine the energy expenditure of SOF conducting military training operations. Thirty-one soldiers taking part in Pre-Mission Training (PMT n = 15) and Combat Diver Qualification Courses (CDQC n = 16) volunteered to participate in this observational study. Energy expenditure was determined using doubly labeled water. Body weight (83 ± 7 kg) remained stable during both training periods. Overall energy expenditure adjusted for body composition was 17,606 ± 2326 kJ·day(-1). Energy expenditure was 19,110 ± 1468 kJ·day(-1) during CDQC and 16,334 ± 2180 kJ·day(-1) during PMT, with physical activity levels of 2.6 ± 0.2 and 2.2 ± 0.3 during CDQC and PMT, respectively. Compared to the Military Dietary Reference Intakes for energy (13,598 kJ·day(-1)), these data are in agreement with previous reports that energy requirement for SOF Soldiers exceed that of the average soldier.
Legionella bozemanae synthesizes phosphatidylcholine from exogenous choline.
Palusinska-Szysz, Marta; Janczarek, Monika; Kalitynski, Rafal; Dawidowicz, Andrzej L; Russa, Ryszard
2011-02-20
The phospholipid class and fatty acid composition of Legionella bozemanae were determined using thin-layer chromatography, gas-liquid chromatography, and matrix-assisted laser desorption ionization-time of flight mass spectrometry. Phosphatidylcholine, phosphatidylethanolamine, and diphosphatidylglycerol were the predominant phospholipids, while phosphatidyl-N-monomethylethanolamine, phosphatidylglycerol, and phosphatidyl-N,N-dimethylethanolamine were present at low concentrations. With the use of the LC/MS technique, PC16:0/15:0, PC17:/15:0, and PE16:1/15:0 were shown to be the dominant phospholipid constituents, which may be taxonomically significant. Two independent phosphatidylcholine synthesis pathways (the three-step methylation and the one-step CDP-choline pathway) were present and functional in L. bozemanae. In the genome of L. bozemanae, genes encoding two potential phosphatidylcholine forming enzymes, phospholipid N-methyl transferase (PmtA) and phosphatidylcholine synthase (Pcs), homologous to L. longbeachae, L. drancourtii, and L. pneumophila pmtA and pcs genes were identified. Genes pmtA and pcs from L. bozemanae were sequenced and analyzed on nucleotide and amino acid levels. Bacteria grown on an artificial medium with labelled choline synthesized phosphatidylcholine predominantly via the phosphatidylcholine synthase pathway, which indicates that L. bozemanae phosphatidylcholine, similarly as in other bacteria associated with eukaryotes, is an important determinant of host-microbe interactions. Copyright © 2010 Elsevier GmbH. All rights reserved.
Babazadeh, Towhid; Kamran, Aziz; Dargahi, Abdollah; Moradi, Fatemeh; Shariat, Fariba; Rezakhani Moghaddam, Hamed
2016-01-01
Background: Skin cancer is a serious public health problem in the world. Its prevalence in many countries has been increased in recent years. This study aimed to assess the effects of a theory-based educational intervention to promote skin cancer preventive behaviors (SCPBs) among rural farmers in Chalderan County, Iran. Methods: This was a quasi-randomized controlled field trial study conducted on 238 rural farmers. The data were collected by a questionnaire containing the constructs of the Protection Motivation Theory (PMT) as well as the items of SCPBs. The differences between the groups before and 3 months after the intervention were determined by independent t-test, paired t-test, and chi-square applying SPSS software. Results: Before the intervention, no significant difference was found in the scores of the PMT constructs between the two groups (p>0.05). However, significant differences were found between the scores of all the variables, as well as SCPBs, in the two groups after the intervention (p<0.05). Conclusion: The PMT was found to be an appropriate framework for designing educational interventions aiming at promoting SCPBs among rural farmers. It was concluded that designing an educational program with a focus on promoting perceived susceptibility increased the level of performing SCPBs among the rural farmers.
Determinants of Cancer Early Detection Behaviors:Application of Protection Motivation Theory.
Rahaei, Zohreh; Ghofranipour, Fazlollah; Morowatisharifabad, Mohammad Ali; Mohammadi, Eesa
2015-01-01
Cancer is account for 13% of all deaths around the world and is the third cause of mortality in Iran. More than one third of these cases are pre-ventable and about 33% are curable with early detection. The aim of this study was to determine the predictors of cancer early detection (CED) behaviors applying Protection Motivation Theory (PMT). In this cross-sectional study, cluster sampling method was employed to recruit 260 individuals of above 20 years old in Yazd, Iran and a researcher designed questionnaire was completed through interviews for each of the respondents. PMT theoretical variables and CED behaviors were the basis of data collection procedure. Participants acquired 64.47% of the protection motivation, 30.97% of the passive and 45.64% of the active behaviors‟ possible scores. Theory constructs predicted 19.8%, 15.6% and 9.6% of the variations for protection motivation, passive and active behavior respectively. Protection motivation was responsible for 3.6% of passive and 8% of active behaviors‟ variations. Considering the scarceness of CED behaviors and the applicability of PMT in predicting these behaviors, utilization of the PMT‟s constructs in any interventional programs to accelerate CED behaviors could be an alternate methodological choice in the cancer control initiatives.
Subclinical hypothyroidism and cognitive dysfunction in the elderly.
Resta, F; Triggiani, V; Barile, G; Benigno, M; Suppressa, P; Giagulli, V A; Guastamacchia, E; Sabbà, C
2012-09-01
While overt hypothyroidism is associated with reversible dementia in the elderly, the relationship of subclinical hypothyroidism with cognition remains a controversial issue. Our aim was to investigate the correlation between subclinical hypothyroidism and cognition in the elderly, with particular reference to long term memory and selective attention. We selected 337 outpatients (177 men and 160 women), mean age 74.3 years, excluding the subjects with thyroid dysfunction and those treated with drugs influencing thyroid function. The score of Mini Mental State Examination (MMSE) was significantly lower in the group of patients with subclinical hypothyroidism than in euthyroid subjects (p<0.03). It was observed that patients with subclinical hypothyroidism had a probability about 2 times greater (RR = 2.028, p<0.05) of developing cognitive impairment. Prose Memory Test (PMT) score resulted significantly lower in subjects with subclinical hypothyroidism (p<0.04). Considering the Matrix Test (MT) score, the performance was slightly reduced in subclinical hypothyroidism (NS). Furthermore, TSH was negatively correlated with MMSE (p<0.04), PMT (p<0.05) and MT score (NS). No correlation was found between FT4 and FT3 and MMSE, PMT and MT score. In the elderly, subclinical hypothyroidism is associated with cognitive impairment, and its impact on specific aspects of cognition (long term memory and selective attention) is less evident.
Mechanical properties of photomultiplier tube glasses for neutrino detection
Dongol, Ruhil; Chambliss, Kameron; Sundaram, Shanmugavelayutham K.; ...
2015-08-31
Photomultiplier tubes (PMT) are one of the primary components of water Cherenkov neutrino detection for the Long Baseline Neutrino Experiment (LBNE). Thousands of 10- to 12-inch diameter PMT bulbs are placed in the inner wall of a detection tank or a reservoir (e.g., deep mine) filled with 10,000 gallons of high purity water with a resistivity of 11–18.24 MΩ-cm. Long-term service of PMTs is vital to the success of neutrino detection projects. We report our results of our investigation on mechanical properties of PMT glasses from two vendors and the effect of ion exchange on their mechanical strength. Vickers indentation,more » four-point bend test, and ring-on-ring biaxial flexural strength test were used for evaluation of the mechanical strength. Chemical (potassium–sodium ion exchange) strengthening results show increased strength of 46% in one vendor glass and a 57% increase in the other, with no significant reduction in optical transmission in the ultraviolet-visible range of the electromagnetic spectrum that is critical to neutrino detection. Finally, our results also show narrowing of the distribution of strength calculated using Weibull statistics with chemical strengthening for comparable exchange depths of 22–28 μm.« less
Babazadeh, Towhid; Kamran, Aziz; Dargahi, Abdollah; Moradi, Fatemeh; Shariat, Fariba; Rezakhani Moghaddam, Hamed
2016-01-01
Background: Skin cancer is a serious public health problem in the world. Its prevalence in many countries has been increased in recent years. This study aimed to assess the effects of a theory-based educational intervention to promote skin cancer preventive behaviors (SCPBs) among rural farmers in Chalderan County, Iran. Methods: This was a quasi-randomized controlled field trial study conducted on 238 rural farmers. The data were collected by a questionnaire containing the constructs of the Protection Motivation Theory (PMT) as well as the items of SCPBs. The differences between the groups before and 3 months after the intervention were determined by independent t-test, paired t-test, and chi-square applying SPSS software. Results: Before the intervention, no significant difference was found in the scores of the PMT constructs between the two groups (p>0.05). However, significant differences were found between the scores of all the variables, as well as SCPBs, in the two groups after the intervention (p<0.05). Conclusion: The PMT was found to be an appropriate framework for designing educational interventions aiming at promoting SCPBs among rural farmers. It was concluded that designing an educational program with a focus on promoting perceived susceptibility increased the level of performing SCPBs among the rural farmers. PMID:28210609
Muon data from a water Cherenkov detector prototype at Colorado State University
NASA Astrophysics Data System (ADS)
Longo, Megan; Mostafa, Miguel
2013-04-01
The High Altitude Water Cherenkov (HAWC) Observatory is a very high energy gamma-ray experiment currently under construction in Sierra Negra in the state of Puebla, Mexico, at an altitude of 4,100 m a.s.l. The HAWC Observatory will consist of 300 water Cherenkov detectors (WCDs), each instrumented with three 8'' photomultiplier tubes (PMTs) and one 10'' high efficiency (HE) PMT. The PMTs are upward facing, anchored to the bottom of a 5 m deep by 7.3 m diameter steel tank, containing a multilayer hermetic plastic bag holding 200,000 L of purified water. The only full size WCD prototype outside of the HAWC site is located at Colorado State University (CSU) in Fort Collins, CO at an altitude of 1,525 m a.s.l. This prototype is instrumented with six 8'' PMTs, one 10'' HE PMT, and the same laser calibration system, electronics, and data acquisition system as the WCDs at the HAWC site. The CSU prototype is additionally equipped with scintillator paddles both under and above the volume of water, temperature probes (in the water, outside, and in the DAQ room), and one covered PMT. Preliminary results for muon rates and their temperature dependance using data collected with the CSU prototype will be presented.
Development of fast-timing microchannel plate photomultiplier
NASA Astrophysics Data System (ADS)
Xie, Junqi
2017-09-01
Planar microchannel plate photomultipliers (MCP-PMTs) with bialkali photocathodes are able to achieve single photon detection with excellent time (picosecond) and spatial (millimeter) resolution. They have recently drawn great interests in experiments requiring time of flight (TOF) measurement and/or Cherenkov imaging. The Argonne MCP-PMT detector group has recently designed and fabricated 6 cm × 6 cm MCP-PMTs. Atomic layer deposition (ALD) method is used to grow resistive and secondary emission layers to functionalize the glass capillary array. Initial characterization indicates that these MCP-PMTs exhibits a transit-time spread of 57 psec at single photoelectron detection mode and of 27 psec at multi photoelectron mode ( 100 photoelectrons). The MCP-PMTs were also tested at Fermilab test beam facility for its particle detection performance and rate capability, showing high rate capability up to 75 kHz/cm2 , higher than the requirement for future electron-ion collider (EIC) experiment. A recent magnetic field test at ANL g-2 magnetic facility shows that the gain of MCP-PMT does not degrade until 0.75 Tesla, comparable to the current commercially available MCP-PMTs. Further improvement of its magnetic field performance is currently under developing by reducing the MCP pore size and spacing between inside components. The progress on the MCP-PMT development at ANL will be presented and discussed in the presentation.
Energy Requirements of US Army Special Operation Forces During Military Training
Margolis, Lee M.; Crombie, Aaron P.; McClung, Holly L.; McGraw, Susan M.; Rood, Jennifer C.; Montain, Scott J.; Young, Andrew J.
2014-01-01
Special Operations Forces (SOF) regularly engage in physically demanding combat operations and field training exercises, resulting in high daily energy expenditure, and thus increased energy requirements. However, the majority of studies assessing energy requirements of SOF have been conducted on soldiers going through intense SOF initiation training. The objective of the current investigation was to determine the energy expenditure of SOF conducting military training operations. Thirty-one soldiers taking part in Pre-Mission Training (PMT n = 15) and Combat Diver Qualification Courses (CDQC n = 16) volunteered to participate in this observational study. Energy expenditure was determined using doubly labeled water. Body weight (83 ± 7 kg) remained stable during both training periods. Overall energy expenditure adjusted for body composition was 17,606 ± 2326 kJ·day−1. Energy expenditure was 19,110 ± 1468 kJ·day−1 during CDQC and 16,334 ± 2180 kJ·day−1 during PMT, with physical activity levels of 2.6 ± 0.2 and 2.2 ± 0.3 during CDQC and PMT, respectively. Compared to the Military Dietary Reference Intakes for energy (13,598 kJ·day−1), these data are in agreement with previous reports that energy requirement for SOF Soldiers exceed that of the average soldier. PMID:24824290
Ylstra, Bauke; Garrido, Dolores; Busscher, Jacqueline; van Tunen, Arjen J.
1998-01-01
We investigated the molecular and physiological processes of sugar uptake and metabolism during pollen tube growth and plant fertilization. In vitro germination assays showed that petunia (Petunia hybrida) pollen can germinate and grow not only in medium containing sucrose (Suc) as a carbon source, but also in medium containing the monosaccharides glucose (Glc) or fructose (Fru). Furthermore, high-performance liquid chromatography analysis demonstrated a rapid and complete conversion of Suc into equimolar amounts of Glc and Fru when pollen was cultured in a medium containing 2% Suc. This indicates the presence of wall-bound invertase activity and uptake of sugars in the form of monosaccharides by the growing pollen tube. A cDNA designated pmt1 (petunia monosaccharide transporter 1), which is highly homologous to plant monosaccharide transporters, was isolated from petunia. Pmt1 belongs to a small gene family and is expressed specifically in the male gametophyte, but not in any other vegetative or floral tissues. Pmt1 is activated after the first pollen mitosis, and high levels of mRNA accumulate in mature and germinating pollen. A model describing the transport of sugars to the style, the conversion of Suc into Glc and Fru, and the active uptake by a monosaccharide transporter into the pollen tube is presented. PMID:9733549
Chen, Xinguang; Yu, Bin; Gao, Mengting; Yan, Hong; Okafor, Chukwuemeka N.
2014-01-01
Background Among millions of people who suffer from schistosomiasis in China, adolescents are at increased risk to be infected. However, there is a lack of theory-guided behavioral prevention intervention programs to protect these adolescents. This study attempted to apply the Protection Motivation Theory (PMT) in predicting intentions to engage in protective behaviors against schistosomiasis infection. Methods The participants were selected using the stratified cluster sampling method. Survey data were collected using anonymous self-reported questionnaire. The advanced structural equation modeling (SEM) method was utilized to assess the complex relationship among schistosomiasis knowledge, previous risk exposure and protective measures in predicting intentions to engage in protective behavior through the PMT constructs. Principal Findings Approximately 70% of participants reported they were always aware of schistosomiasis before exposure to water with endemic schistosomiasis, 6% of the participants reported frequency of weekly or monthly prior exposure to snail-conditioned water. 74% of participants reported having always engaged in protective behaviors in the past three months. Approximately 7% were unlikely or very unlikely to avoid contact with snail-conditioned water, and to use protective behaviors before exposure. Results from SEM analysis indicated that both schistosomiasis knowledge and prior exposure to schistosomiasis were indirectly related to behavior intentions through intrinsic rewards and self-efficacy; prior protective behaviors were indirectly related to behavior intentions through severity, intrinsic rewards and self-efficacy, while awareness had an indirect relationship with behavior intentions through self-efficacy. Among the seven PMT constructs, severity, intrinsic rewards and self-efficacy were significantly associated with behavior intentions. Conclusions The PMT can be used to predict the intention to engage in protective behaviors against schistosomiasis. Schistosomiasis intervention programs should focus on the severity, intrinsic rewards and self-efficacy of protection motivation, and also increase the awareness of infection, and enrich the contents of schistosomiasis education. PMID:25329829
Xia, Ke; Liu, Xiaoqiang; Zhang, Qiaozhuo; Qiang, Wei; Guo, Jianjun; Lan, Xiaozhong; Chen, Min; Liao, Zhihua
2016-09-01
Atropa belladonna is one of the most important plant sources for producing pharmaceutical tropane alkaloids (TAs). T1 progeny of transgenic A. belladonna, in which putrescine N-methyltransferase (EC. 2.1.1.53) from Nicotiana tabacum (NtPMT) and hyoscyamine 6β-hydroxylase (EC. 1.14.11.14) from Hyoscyamus niger (HnH6H) were overexpressed, were established to investigate TA biosynthesis and distribution in ripe fruits, leaves, stems, primary roots and secondary roots under field conditions. Both NtPMT and HnH6H were detected at the transcriptional level in transgenic plants, whereas they were not detected in wild-type plants. The transgenes did not influence the root-specific expression patterns of endogenous TA biosynthetic genes in A. belladonna. All four endogenous TA biosynthetic genes (AbPMT, AbTRI, AbCYP80F1 and AbH6H) had the highest/exclusive expression levels in secondary roots, suggesting that TAs were mainly synthesized in secondary roots. T1 progeny of transgenic A. belladonna showed an impressive scopolamine-rich chemotype that greatly improved the pharmaceutical value of A. belladonna. The higher efficiency of hyoscyamine conversion was found in aerial than in underground parts. In aerial parts of transgenic plants, hyoscyamine was totally converted to downstream alkaloids, especially scopolamine. Hyoscyamine, anisodamine and scopolamine were detected in underground parts, but scopolamine and anisodamine were more abundant than hyoscyamine. The exclusively higher levels of anisodamine in roots suggested that it might be difficult for its translocation from root to aerial organs. T1 progeny of transgenic A. belladonna, which produces scopolamine at very high levels (2.94-5.13 mg g(-1)) in field conditions, can provide more valuable plant materials for scopolamine production. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Genomic organization of plant aminopropyl transferases.
Rodríguez-Kessler, Margarita; Delgado-Sánchez, Pablo; Rodríguez-Kessler, Gabriela Theresia; Moriguchi, Takaya; Jiménez-Bremont, Juan Francisco
2010-07-01
Aminopropyl transferases like spermidine synthase (SPDS; EC 2.5.1.16), spermine synthase and thermospermine synthase (SPMS, tSPMS; EC 2.5.1.22) belong to a class of widely distributed enzymes that use decarboxylated S-adenosylmethionine as an aminopropyl donor and putrescine or spermidine as an amino acceptor to form in that order spermidine, spermine or thermospermine. We describe the analysis of plant genomic sequences encoding SPDS, SPMS, tSPMS and PMT (putrescine N-methyltransferase; EC 2.1.1.53). Genome organization (including exon size, gain and loss, as well as intron number, size, loss, retention, placement and phase, and the presence of transposons) of plant aminopropyl transferase genes were compared between the genomic sequences of SPDS, SPMS and tSPMS from Zea mays, Oryza sativa, Malus x domestica, Populus trichocarpa, Arabidopsis thaliana and Physcomitrella patens. In addition, the genomic organization of plant PMT genes, proposed to be derived from SPDS during the evolution of alkaloid metabolism, is illustrated. Herein, a particular conservation and arrangement of exon and intron sequences between plant SPDS, SPMS and PMT genes that clearly differs with that of ACL5 genes, is shown. The possible acquisition of the plant SPMS exon II and, in particular exon XI in the monocot SPMS genes, is a remarkable feature that allows their differentiation from SPDS genes. In accordance with our in silico analysis, functional complementation experiments of the maize ZmSPMS1 enzyme (previously considered to be SPDS) in yeast demonstrated its spermine synthase activity. Another significant aspect is the conservation of intron sequences among SPDS and PMT paralogs. In addition the existence of microsynteny among some SPDS paralogs, especially in P. trichocarpa and A. thaliana, supports duplication events of plant SPDS genes. Based in our analysis, we hypothesize that SPMS genes appeared with the divergence of vascular plants by a processes of gene duplication and the acquisition of unique exons of as-yet unknown origin. 2010 Elsevier Masson SAS. All rights reserved.
Xiao, Han; Li, Shiyue; Chen, Xinguang; Yu, Bin; Gao, Mengting; Yan, Hong; Okafor, Chukwuemeka N
2014-10-01
Among millions of people who suffer from schistosomiasis in China, adolescents are at increased risk to be infected. However, there is a lack of theory-guided behavioral prevention intervention programs to protect these adolescents. This study attempted to apply the Protection Motivation Theory (PMT) in predicting intentions to engage in protective behaviors against schistosomiasis infection. The participants were selected using the stratified cluster sampling method. Survey data were collected using anonymous self-reported questionnaire. The advanced structural equation modeling (SEM) method was utilized to assess the complex relationship among schistosomiasis knowledge, previous risk exposure and protective measures in predicting intentions to engage in protective behavior through the PMT constructs. Approximately 70% of participants reported they were always aware of schistosomiasis before exposure to water with endemic schistosomiasis, 6% of the participants reported frequency of weekly or monthly prior exposure to snail-conditioned water. 74% of participants reported having always engaged in protective behaviors in the past three months. Approximately 7% were unlikely or very unlikely to avoid contact with snail-conditioned water, and to use protective behaviors before exposure. Results from SEM analysis indicated that both schistosomiasis knowledge and prior exposure to schistosomiasis were indirectly related to behavior intentions through intrinsic rewards and self-efficacy; prior protective behaviors were indirectly related to behavior intentions through severity, intrinsic rewards and self-efficacy, while awareness had an indirect relationship with behavior intentions through self-efficacy. Among the seven PMT constructs, severity, intrinsic rewards and self-efficacy were significantly associated with behavior intentions. The PMT can be used to predict the intention to engage in protective behaviors against schistosomiasis. Schistosomiasis intervention programs should focus on the severity, intrinsic rewards and self-efficacy of protection motivation, and also increase the awareness of infection, and enrich the contents of schistosomiasis education.
Herrera, Santiago; Comerota, Anthony J; Thakur, Subhash; Sunderji, Shiraz; DiSalle, Robert; Kazanjian, Sahira N; Assi, Zakaria
2014-02-01
Extensive deep venous thrombosis (DVT) during pregnancy is usually treated with anticoagulation alone, risking significant post-thrombotic syndrome (PTS) in young patients. Catheter-directed thrombolysis (CDT) and operative venous thrombectomy have been safely and effectively used in nonpregnant patients, demonstrating significant reduction in post-thrombotic morbidity. This report reviews short- and long-term outcomes of 13 patients with extensive DVT of pregnancy treated with a strategy of thrombus removal. From 1999 to 2013, 13 patients with iliofemoral DVT during pregnancy were offered CDT, pharmacomechanical thrombolysis (PMT), and/or venous thrombectomy. Gestational age ranged from 8 to 34 weeks. Fetal monitoring was performed throughout hospitalization. Radiation exposure was minimized with pelvic lead shields, focal fluoroscopy, and limited angiographic runs. Follow-up included objective vein evaluation using venous duplex and PTS assessment using the Villalta scale. CDT and/or PMT were used in 11 patients. Two patients underwent venous thrombectomy alone, and one patient had operative thrombectomy as an adjunct to CDT and PMT. Each patient had complete or near-complete thrombus resolution and rapid improvement in clinical symptoms. Eight of 11 having CDT or PMT underwent venoplasty and stenting of the involved iliac veins. Twelve of the 13 delivered healthy infants at term. One patient opted for termination of her pregnancy. Mean patient and gestational ages were 26 years and 26 weeks, respectively. Mean follow-up was 1.3 years, with only one recurrence. Duplex ultrasonography demonstrated patent veins in all but one patient and normal valve function in 10 patients. Eleven patients had Villalta scores <5 (considered normal), with a mean score of 0.7. Extensive DVT of pregnancy can be effectively and safely treated with a strategy of thrombus removal, resulting in a patent venous system, normal valve function in many, prevention of PTS, and reduction in recurrence. Copyright © 2014. Published by Mosby, Inc.
Sit, Regina Wing Shan; Chan, Keith Kwok Wai; Yip, Benjamin Hon Kei; Zhang, Daisy Dexing; Reeves, Kenneth Dean; Chan, Ying Ho; Chung, Vincent Chi Ho; Wong, Samuel Yeung Shan
2018-03-14
Knee osteoarthritis (KOA) is a common, disabling and costly medical condition. The patellofemoral joint is a critical source of pain in individuals with KOA, and coexistence of patellofemoral osteoarthritis (PFOA) and tibiofemoral osteoarthritis (TFOA) is sometimes observed. The identification of subgroups with PFOA and customised interventions to correct underlying pathomechanics is beneficial for individuals with KOA. This study aims to evaluate whether a clinic-based patella mobilisation therapy (PMT) leads to significant improvement in pain, physical function and quality of life of individuals with KOA. A total of 208 participants with coexistence of PFOA and TFOA will be recruited. A pragmatic randomised clinical trial will be conducted, and participants will be randomised into the PMT and waiting list groups. For the PMT group, three manual mobilisation sessions, along with home-based vastus medialis oblique muscle exercise, will be conducted at 2-month intervals. The waiting list group will continue to receive their usual care, and as an incentive the waiting list group will be offered PMT after the study period is over. The primary outcome is the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain subscale, and secondary outcomes include the WOMAC function and stiffness subscales, scores for objective physical function tests (the 30 s chair stand, 40-metre fast-paced walk test, the Timed Up and Go Test), and the EuroQol-5D scores. All outcomes will be evaluated at baseline and 6 months using intention-to-treat and incorporating covariate analysis. Ethics approval has been obtained (CREC no: 2014.379). Results of the trial will be submitted for publication in a peer-reviewed journal. ChiCTR-IPC-15006618; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
The Life Course Perspective: a Guide for Genetic Counselors.
Hamilton, Rebekah J; Innella, Nancy A; Bounds, Dawn T
2016-02-01
This is the first article in a two part series about utilizing the life course perspective (LCP) in genetic counseling. LCP can be a useful tool for genetic counselors when counseling people with a known genetic mutation. Previous theories such as Protection Motivation Theory (PMT) and Common Sense Model of Self-Regulation (CSMSR) examine current reactions to a positive genetic test result. LCP extends beyond the current time to explore temporal and contextual elements of the experience. A review of research revealed, LCP has been used to study the perspective of caregivers of people with Alzheimer's disease, referral for a family history of breast cancer, Mexican American caregivers of older adult, social class and cancer incidence and cancer and the sense of mastery. Incorporating LCP into a study explaining the experiences of people living with a positive test result for a genetic mutation such as the BRCA mutation provides a comprehensive exploration of this experience.
Design and Implementation of High Precision Temperature Measurement Unit
NASA Astrophysics Data System (ADS)
Zeng, Xianzhen; Yu, Weiyu; Zhang, Zhijian; Liu, Hancheng
2018-03-01
Large-scale neutrino detector requires calibration of photomultiplier tubes (PMT) and electronic system in the detector, performed by plotting the calibration source with a group of designated coordinates in the acrylic sphere. Where the calibration source positioning is based on the principle of ultrasonic ranging, the transmission speed of ultrasonic in liquid scintillator of acrylic sphere is related to temperature. This paper presents a temperature measurement unit based on STM32L031 and single-line bus digital temperature sensor TSic506. The measurement data of the temperature measurement unit can help the ultrasonic ranging to be more accurate. The test results show that the temperature measurement error is within ±0.1°C, which satisfies the requirement of calibration source positioning. Take energy-saving measures, with 3.7V/50mAH lithium battery-powered, the temperature measurement unit can work continuously more than 24 hours.
Time-domain laser-induced fluorescence spectroscopy apparatus for clinical diagnostics
NASA Astrophysics Data System (ADS)
Fang, Qiyin; Papaioannou, Thanassis; Jo, Javier A.; Vaitha, Russel; Shastry, Kumar; Marcu, Laura
2004-01-01
We report the design and development of a compact optical fiber-based apparatus for in situ time-resolved laser-induced fluorescence spectroscopy (tr-LIFS) of biological systems. The apparatus is modular, optically robust, and compatible with the clinical environment. It incorporates a dual output imaging spectrograph, a gated multichannel plate photomultiplier (MCP-PMT), an intensified charge-coupled-device (ICCD) camera, and a fast digitizer. It can accommodate various types of light sources and optical fiber probes for selective excitation and remote light delivery/collection as required by different applications. The apparatus allows direct recording of the entire fluorescence decay with high sensitivity (nM range fluorescein dye concentration with signal-to-noise ratio of 46) and with four decades dynamic range. It is capable of resolving a broad range of fluorescence lifetimes from hundreds of picoseconds (as low as 300 ps) using the MCP-PMT coupled to the digitizer to milliseconds using the ICCD. The data acquisition and analysis process is fully automated, enabling fast recording of fluorescence intensity decay across the entire emission spectrum (0.8 s per wavelength or ˜40 s for a 200 nm wavelength range at 5 nm increments). The spectral and temporal responses of the apparatus were calibrated and its performance was validated using fluorescence lifetime standard dyes (Rhodamin B, 9-cyanoanthracene, and rose Bengal) and tissue endogenous fluorophores (elastin, collagen, nicotinamide adenine dinucleotide, and flavin adenine dinucleotide). Fluorescence decay lifetimes and emission spectra of all tested compounds measured with the current tr-LIFS apparatus were found in good agreement with the values reported in the literature. The design and performance of tr-LIFS apparatus have enabled in vivo studies of atherosclerotic plaques and brain tumors.
A novel PMT test system based on waveform sampling
NASA Astrophysics Data System (ADS)
Yin, S.; Ma, L.; Ning, Z.; Qian, S.; Wang, Y.; Jiang, X.; Wang, Z.; Yu, B.; Gao, F.; Zhu, Y.; Wang, Z.
2018-01-01
Comparing with the traditional test system based on a QDC and TDC and scaler, a test system based on waveform sampling is constructed for signal sampling of the 8"R5912 and the 20"R12860 Hamamatsu PMT in different energy states from single to multiple photoelectrons. In order to achieve high throughput and to reduce the dead time in data processing, the data acquisition software based on LabVIEW is developed and runs with a parallel mechanism. The analysis algorithm is realized in LabVIEW and the spectra of charge, amplitude, signal width and rising time are analyzed offline. The results from Charge-to-Digital Converter, Time-to-Digital Converter and waveform sampling are discussed in detailed comparison.
Lithium rechargeable cell with a polymer cathode
NASA Astrophysics Data System (ADS)
Walker, Charles W., Jr.
1991-11-01
Thin films of electropolymerized poly 3-methylthiophene (PMT) were used as a rechargeable cathode in Li(SO2)3AlCl4 electrolyte. Capacity was superior to porous carbon electrodes of like thickness. Pulse power levels of 2 W cm-2 were achieved, and high rate constant current pulses of four-second duration were reproducible over cycles. Cells could be recharged at potentials below 4.0 V, minimizing the formation of chlorine and thereby diminishing the capacity for corrosion. For a primary cell, greater discharge capacity was obtained with thionyl chloride and sulfuryl chloride electrolytes. Since PMT becomes electrically insulating in the reduced state, this could be used as a built-in safety feature to avert the hazards associated with abuse over-discharge.
Narrowband NanoSat Scale Photometry for VUV Planetary and Heliophysics missions
NASA Astrophysics Data System (ADS)
Noto, J.; Doe, R. A.; Frey, H. U.
2015-12-01
Remote vacuum ultraviolet (VUV) soundings to support Explorer-class atmospheric research are typically enabled by large aperture, wideband spectrographs carefully pointed to measure a planet's disk and limb regions (i.e. TIMED/GUVI and MAVEN/UVS). An alternate measurement paradigm is to identify key aeronomical emission targets (i.e HI 121.6-nm, OI 135.6-nm, N2 Lyman-Birge-Hopfield band 135 - 155 nm) and create a series of narrowband photometers each with greater in-band sensitivity (relative to a spectrograph) due to enhanced out-of-band rejection and absence of a dispersive element. Recent advances in narrowband VUV coating and PMT miniaturization have enabled design of a dual-channel nanosatellite-scale VUV photometer with flight heritage significantly leveraged from the NASA POLAR UVI imager the Air Force CubeSat Tiny Ionospheric Photometer (CTIP). Herein we present further modeled sensitivity studies and current build status of the dual-channel thermosphere/ionosphere photometer (DTIP) and address notional missions including dayside O/N2 composition, auroral energetics, nightside plasma structuring and peak layer characterization, and hydrogen geocoronal tomographic imaging.
Free-running ADC- and FPGA-based signal processing method for brain PET using GAPD arrays
NASA Astrophysics Data System (ADS)
Hu, Wei; Choi, Yong; Hong, Key Jo; Kang, Jihoon; Jung, Jin Ho; Huh, Youn Suk; Lim, Hyun Keong; Kim, Sang Su; Kim, Byung-Tae; Chung, Yonghyun
2012-02-01
Currently, for most photomultiplier tube (PMT)-based PET systems, constant fraction discriminators (CFD) and time to digital converters (TDC) have been employed to detect gamma ray signal arrival time, whereas anger logic circuits and peak detection analog-to-digital converters (ADCs) have been implemented to acquire position and energy information of detected events. As compared to PMT the Geiger-mode avalanche photodiodes (GAPDs) have a variety of advantages, such as compactness, low bias voltage requirement and MRI compatibility. Furthermore, the individual read-out method using a GAPD array coupled 1:1 with an array scintillator can provide better image uniformity than can be achieved using PMT and anger logic circuits. Recently, a brain PET using 72 GAPD arrays (4×4 array, pixel size: 3 mm×3 mm) coupled 1:1 with LYSO scintillators (4×4 array, pixel size: 3 mm×3 mm×20 mm) has been developed for simultaneous PET/MRI imaging in our laboratory. Eighteen 64:1 position decoder circuits (PDCs) were used to reduce GAPD channel number and three off-the-shelf free-running ADC and field programmable gate array (FPGA) combined data acquisition (DAQ) cards were used for data acquisition and processing. In this study, a free-running ADC- and FPGA-based signal processing method was developed for the detection of gamma ray signal arrival time, energy and position information all together for each GAPD channel. For the method developed herein, three DAQ cards continuously acquired 18 channels of pre-amplified analog gamma ray signals and 108-bit digital addresses from 18 PDCs. In the FPGA, the digitized gamma ray pulses and digital addresses were processed to generate data packages containing pulse arrival time, baseline value, energy value and GAPD channel ID. Finally, these data packages were saved to a 128 Mbyte on-board synchronous dynamic random access memory (SDRAM) and then transferred to a host computer for coincidence sorting and image reconstruction. In order to evaluate the functionality of the developed signal processing method, energy and timing resolutions for brain PET were measured via the placement of a 6 μCi 22Na point source at the center of the PET scanner. Furthermore the PET image of the hot rod phantom (rod diameter: from 2.5 mm to 6.5 mm) with activity of 1 mCi was simulated, and then image acquisition experiment was performed using the brain PET. Measured average energy resolution for 1152 GAPD channels and system timing resolution were 19.5% (FWHM%) and 2.7 ns (FWHM), respectively. With regard to the acquisition of the hot rod phantom image, rods could be resolved down to a diameter of 2.5 mm, which was similar to simulated results. The experimental results demonstrated that the signal processing method developed herein was successfully implemented for brain PET. This reduced the complexity, cost and developing duration for PET system relative to normal PET electronics, and it will obviously be useful for the development of high-performance investigational PET systems.
Liang, Xiaohui; Fang, Xiangyi; Yao, Manwen; Yang, Yucong; Li, Junfeng; Liu, Hongjun; Wang, Linyu
2016-02-01
Direct competitive chemiluminescence immunoassays (CLIA) based on gold-coated magnetic nanospheres (Au-MNPs) were developed for rapid analysis of chloramphenicol (CAP). The Au-MNPs were modified with carboxyl groups and amino groups by 11-mercaptoundecanoic acid (MUA) and cysteamine respectively, and then were respectively conjugated with CAP base and CAP succinate via an activating reaction using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS). NSP-DMAE-NHS, a new and effective luminescence reagent, was employed to label anti-CAP antibody (mAb) as a tracer in direct CLIA for CAP detection using a 'homemade' luminescent measurement system that was set up with a photomultiplier tube (PMT) and a photon counting unit linked to a computer. The sensitivities and limits of detection (LODs) of the two methods were obtained and compared according to the inhibition curves. The 50% inhibition concentration (IC50 ) values of the two methods were about 0.044 ng/mL and 0.072 ng/mL respectively and LODs were approximately 0.001 ng/mL and 0.006 ng/mL respectively. To our knowledge, they were much more sensitive than any traditional enzyme-linked immunosorbent assay (ELISA) ever reported. Moreover, the new luminescence reagent NSP-DMAE-NHS is much more sensitive and stable than luminol and its derivatives, contributing to the sensitivity enhancement. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Ding, Xuemei; Wang, Bingyuan; Liu, Dongyuan; Zhang, Yao; He, Jie; Zhao, Huijuan; Gao, Feng
2018-02-01
During the past two decades there has been a dramatic rise in the use of functional near-infrared spectroscopy (fNIRS) as a neuroimaging technique in cognitive neuroscience research. Diffuse optical tomography (DOT) and optical topography (OT) can be employed as the optical imaging techniques for brain activity investigation. However, most current imagers with analogue detection are limited by sensitivity and dynamic range. Although photon-counting detection can significantly improve detection sensitivity, the intrinsic nature of sequential excitations reduces temporal resolution. To improve temporal resolution, sensitivity and dynamic range, we develop a multi-channel continuous-wave (CW) system for brain functional imaging based on a novel lock-in photon-counting technique. The system consists of 60 Light-emitting device (LED) sources at three wavelengths of 660nm, 780nm and 830nm, which are modulated by current-stabilized square-wave signals at different frequencies, and 12 photomultiplier tubes (PMT) based on lock-in photon-counting technique. This design combines the ultra-high sensitivity of the photon-counting technique with the parallelism of the digital lock-in technique. We can therefore acquire the diffused light intensity for all the source-detector pairs (SD-pairs) in parallel. The performance assessments of the system are conducted using phantom experiments, and demonstrate its excellent measurement linearity, negligible inter-channel crosstalk, strong noise robustness and high temporal resolution.
Characterization of porcine eyes based on autofluorescence lifetime imaging
NASA Astrophysics Data System (ADS)
Batista, Ana; Breunig, Hans Georg; Uchugonova, Aisada; Morgado, António Miguel; König, Karsten
2015-03-01
Multiphoton microscopy is a non-invasive imaging technique with ideal characteristics for biological applications. In this study, we propose to characterize three major structures of the porcine eye, the cornea, crystalline lens, and retina using two-photon excitation fluorescence lifetime imaging microscopy (2PE-FLIM). Samples were imaged using a laser-scanning microscope, consisting of a broadband sub-15 femtosecond (fs) near-infrared laser. Signal detection was performed using a 16-channel photomultiplier tube (PMT) detector (PML-16PMT). Therefore, spectral analysis of the fluorescence lifetime data was possible. To ensure a correct spectral analysis of the autofluorescence lifetime data, the spectra of the individual endogenous fluorophores were acquired with the 16-channel PMT and with a spectrometer. All experiments were performed within 12h of the porcine eye enucleation. We were able to image the cornea, crystalline lens, and retina at multiple depths. Discrimination of each structure based on their autofluorescence intensity and lifetimes was possible. Furthermore, discrimination between different layers of the same structure was also possible. To the best of our knowledge, this was the first time that 2PE-FLIM was used for porcine lens imaging and layer discrimination. With this study we further demonstrated the feasibility of 2PE-FLIM to image and differentiate three of the main components of the eye and its potential as an ophthalmologic technique.
Dehghan, Esmaeil; Reed, Darwin W; Covello, Patrick S; Hasanpour, Zeinab; Palazon, Javier; Oksman-Caldentey, Kirsi-Marja; Ahmadi, Farajollah Shahriari
2017-10-01
Tetraploidy improves overexpression of h6h and scopolamine production of H. muticus, while in H. senecionis, pmt overexpression and elicitation can be used as effective methods for increasing tropane alkaloids. The effects of metabolic engineering in a polyploid context were studied by overexpression of h6h in the tetraploid hairy root cultures of H. muticus. Flow cytometry analysis indicated genetic stability in the majority of the clones, while only a few clones showed genetic instability. Among all the diploid and tetraploid clones, the highest level of h6h transgene expression and scopolamine accumulation was interestingly observed in the tetraploid clones of H. muticus. Therefore, metabolic engineering of the tropane biosynthetic pathway in polyploids is suggested as a potential system for increasing the production of tropane alkaloids. Transgenic hairy root cultures of Hyoscyamus senecionis were also established. While overexpression of pmt in H. senecionis was correlated with a sharp increase in hyoscyamine production, the h6h-overexpressing clones were not able to accumulate higher levels of scopolamine than the leaves of intact plants. Applying methyl jasmonate was followed by a sharp increase in the expression of pmt and a drop in the expression of tropinone reductase II (trII) which consequently resulted in the higher biosynthesis of hyoscyamine and total alkaloids in H. senecionis.
Vallone, Alessandra; D'Alessandro, Sarah; Brogi, Simone; Brindisi, Margherita; Chemi, Giulia; Alfano, Gloria; Lamponi, Stefania; Lee, Soon Goo; Jez, Joseph M; Koolen, Karin J M; Dechering, Koen J; Saponara, Simona; Fusi, Fabio; Gorelli, Beatrice; Taramelli, Donatella; Parapini, Silvia; Caldelari, Reto; Campiani, Giuseppe; Gemma, Sandra; Butini, Stefania
2018-04-25
Therapies addressing multiple stages of Plasmodium falciparum life cycle are highly desirable for implementing malaria elimination strategies. MMV019918 (1, 1-[5-(4-bromo-2-chlorophenyl)furan-2-yl]-N-[(piperidin-4-yl)methyl]methanamine) was selected from the MMV Malaria Box for its dual activity against both asexual stages and gametocytes. In-depth structure-activity relationship studies and cytotoxicity evaluation led to the selection of 25 for further biological investigation. The potential transmission blocking activity of 25 versus P. falciparum was confirmed through the standard membrane-feeding assay. Both 1 and 25 significantly prolonged atrioventricular conduction time in Langendorff-isolated rat hearts, and showed inhibitory activity of Ba 2+ current through Ca v 1.2 channels. An in silico target-fishing study suggested the enzyme phosphoethanolamine methyltransferase (PfPMT) as a potential target. However, compound activity against PfPMT did not track with the antiplasmodial activity, suggesting the latter activity relies on a different molecular target. Nevertheless, 25 showed interesting activity against PfPMT, which could be an important starting point for the identification of more potent inhibitors active against both sexual and asexual stages of the parasite. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Advanced Mass Spectrometric Methods for the Rapid and Quantitative Characterization of Proteomes
Smith, Richard D.
2002-01-01
Progress is reviewedmore » towards the development of a global strategy that aims to extend the sensitivity, dynamic range, comprehensiveness and throughput of proteomic measurements based upon the use of high performance separations and mass spectrometry. The approach uses high accuracy mass measurements from Fourier transform ion cyclotron resonance mass spectrometry (FTICR) to validate peptide ‘accurate mass tags’ (AMTs) produced by global protein enzymatic digestions for a specific organism, tissue or cell type from ‘potential mass tags’ tentatively identified using conventional tandem mass spectrometry (MS/MS). This provides the basis for subsequent measurements without the need for MS/ MS. High resolution capillary liquid chromatography separations combined with high sensitivity, and high resolution accurate FTICR measurements are shown to be capable of characterizing peptide mixtures of more than 10 5 components. The strategy has been initially demonstrated using the microorganisms Saccharomyces cerevisiae and Deinococcus radiodurans. Advantages of the approach include the high confidence of protein identification, its broad proteome coverage, high sensitivity, and the capability for stableisotope labeling methods for precise relative protein abundance measurements. Abbreviations : LC, liquid chromatography; FTICR, Fourier transform ion cyclotron resonance; AMT, accurate mass tag; PMT, potential mass tag; MMA, mass measurement accuracy; MS, mass spectrometry; MS/MS, tandem mass spectrometry; ppm, parts per million.« less
NASA Astrophysics Data System (ADS)
Bigu, J.; Elliott, J.
1994-05-01
An instrument has been developed for continuous monitoring of 220Rn. The method of data analysis is based on delayed coincidences between 220Rn and 216Po. The instrument basically consists of a scaler equipped with a photomultiplier tube (PMT) to which a scintillation cell (SC) of the flow through type is optically coupled. The scaler is equipped with a pulse output (P/O) port which provides a TTL pulse, +5 V in amplitude and 5 to 10 μs duration for each nuclear event recorded by the SC and its associated electronic circuitry. The P/O port is connected to a 32 bit counter/timer unit operating at 1 MHz which records and stores the time of arrival of pulses. For laboratory use, the counter/timer is connected to the serial port of a laptop PC. However, for field applications, where space and weight pose severe practical limitations, the PC is substituted by an expanded counter/timer unit which incorporates a muprocessor for data analysis, a LCD for data display, and a keypad to key in function instructions. Furthermore, some additional hardware permits the measurement of 220Rn flux density, J( 220Rn) , from soils and other materials. Because total α-particle count, as well as delayed (α - α) coincidence rates are recorded in two separate channels, the method permits the measurement of 222Rn in addition to 220Rn. The method is particularly useful for low concentration levels. The sensitivity of the method primarily depends on the volume of the SC. For a low volume SC (˜0.16 l), a sensitivity of 0.2 h -1/Bq m -3 for 220Rn and 1.4 h -1/Bq m -3 for 222Rn are readily attainable. For a large volume (1.5 l) SC (external PMT used), the sensitivity for 220Rn is ≥ 1.5 h -1/Bq m -3, depending on the SC design and the operating sampling flowrate. (Note: h -1 stands for counts per hour). The above instrument has been used extensively at the National Radon/Thoron Test Facility (NRTTF) of the Elliot Lake Laboratory for routine monitoring of 220Rn levels since 1992. It has also been used for outdoor and indoor 220Rn measurements, as well as for the determination of J( 220Rn) from earthen materials and the like.
The Flash ADC system and PMT waveform reconstruction for the Daya Bay experiment
NASA Astrophysics Data System (ADS)
Huang, Yongbo; Chang, Jinfan; Cheng, Yaping; Chen, Zhang; Hu, Jun; Ji, Xiaolu; Li, Fei; Li, Jin; Li, Qiuju; Qian, Xin; Jetter, Soeren; Wang, Wei; Wang, Zheng; Xu, Yu; Yu, Zeyuan
2018-07-01
To better understand the energy response of the Antineutrino Detector (AD), the Daya Bay Reactor Neutrino Experiment installed a full Flash ADC readout system on one AD that allowed for simultaneous data taking with the current readout system. This paper presents the design, data acquisition, and simulation of the Flash ADC system, and focuses on the PMT waveform reconstruction algorithms. For liquid scintillator calorimetry, the most critical requirement to waveform reconstruction is linearity. Several common reconstruction methods were tested but the linearity performance was not satisfactory. A new method based on the deconvolution technique was developed with 1% residual non-linearity, which fulfills the requirement. The performance was validated with both data and Monte Carlo (MC) simulations, and 1% consistency between them has been achieved.
Data acquisition system for segmented reactor antineutrino detector
NASA Astrophysics Data System (ADS)
Hons, Z.; Vlášek, J.
2017-01-01
This paper describes the data acquisition system used for data readout from the PMT channels of a segmented detector of reactor antineutrinos with active shielding. Theoretical approach to the data acquisition is described and two possible solutions using QDCs and digitizers are discussed. Also described are the results of the DAQ performance during routine data taking operation of DANSS. DANSS (Detector of the reactor AntiNeutrino based on Solid Scintillator) is a project aiming to measure a spectrum of reactor antineutrinos using inverse beta decay (IBD) in a plastic scintillator. The detector is located close to an industrial nuclear reactor core and is covered by passive and active shielding. It is expected to have about 15000 IBD interactions per day. Light from the detector is sensed by PMT and SiPM.
Quality Assurance on Undoped CsI Crystals for the Mu2e Experiment
NASA Astrophysics Data System (ADS)
Atanov, N.; Baranov, V.; Budagov, J.; Davydov, Yu. I.; Glagolev, V.; Tereshchenko, V.; Usubov, Z.; Cervelli, F.; Di Falco, S.; Donati, S.; Morescalchi, L.; Pedreschi, E.; Pezzullo, G.; Raffaelli, F.; Spinella, F.; Colao, F.; Cordelli, M.; Corradi, G.; Diociaiuti, E.; Donghia, R.; Giovannella, S.; Happacher, F.; Martini, M.; Miscetti, S.; Ricci, M.; Saputi, A.; Sarra, I.; Echenard, B.; Hitlin, D. G.; Hu, C.; Miyashita, T.; Porter, F.; Zhang, L.; Zhu, R.-Y.; Grancagnolo, F.; Tassielli, G.; Murat, P.
2018-02-01
The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm, and is readout by a large area silicon PMT array. A series of technical specifications was defined according to physics requirements. Preproduction CsI crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai Institute of Ceramics. We report the quality assurance on crystal's scintillation properties and their radiation hardness against ionization dose and neutrons. With a fast decay time of 30 ns and a light output of more than 100 p.e./MeV measured with a bi-alkali PMT, undoped CsI crystals provide a cost-effective solution for the Mu2e experiment.
Status of the TORCH time-of-flight detector
NASA Astrophysics Data System (ADS)
Harnew, N.; Brook, N. H.; Castillo García, L.; Cussans, D.; van Dijk, M. W. U.; Föhl, K.; Forty, R.; Frei, C.; Gao, R.; Gys, T.; Hancock, T. H.; Piedigrossi, D.; Rademacker, J.; Ros García., A.
2017-11-01
The TORCH time-of-flight detector is designed for large-area coverage, up to 30 m2, to provide particle identification between 2-10 GeV/c momentum over a flight distance of 10 m. The arrival times from Cherenkov photons produced within a quartz radiator plate of 10 mm thickness are combined to achieve a 15 ps time-of-flight resolution per incident particle. Micro-Channel Plate Photomultiplier Tube (MCP-PMT) detectors of 53 × 53 mm2 active area have been developed with industrial partners for the TORCH application. The MCP-PMT is read out using charge division to give a 128 × 8 effective granularity. Laboratory results of development MCP-PMTs will be described, and testbeam studies using a small-scale TORCH prototype module will be presented.
Detection of sub micro Gray dose levels using OSL phosphor LiMgPO4:Tb,B
NASA Astrophysics Data System (ADS)
Rawat, N. S.; Dhabekar, Bhushan; Muthe, K. P.; Koul, D. K.; Datta, D.
2017-04-01
Detection of sub micro Gray doses finds application in personnel and environmental monitoring, and nuclear forensics. Recently developed LiMgPO4:Tb,B (LMP) is highly sensitive Optically Stimulated Luminescence (OSL) phosphor with excellent dosimetric properties. The OSL emission spectrum of LMP consists of several peaks attributed to characteristic Tb3+ emission. The OSL emission peak at 380 nm is favorable for bi-alkali PMT used in RISO reader system. It is demonstrated that significant improvement in dose detection threshold can be realized for LMP by optimization of continuous wave (CW-) OSL parameters like stimulation intensity and readout time. The minimum measurable dose (MMD) as low as 0.49 μGy in readout time of less than 1 s at stimulation intensity of 32 mW/cm2 has been achieved using this phosphor. The recommendations for choice of parameters for personnel and environmental monitoring are also discussed.
CHARACTERIZATION OF CLYC SCINTILLATOR COUPLED WITH PHOTOMULTIPLIERS AND A LARGE SIPM ARRAY.
Dinar, N; Celeste, D; Puzo, P; Silari, M
2017-09-29
CERN Radiation Protection group has recently developed a novel radiation survey meter called B-RAD able to operate in the presence of a strong magnetic field. The B-RAD will be equipped with a series of probes for gamma dose rate, gamma spectrometry and surface contamination measurements. The feasibility of developing a probe for neutron dose rate and possibly spectral measurements is being investigated. The determination of the breakdown voltage of the SiPM as well as its uniformity between the pixels was performed. The energy resolution of the Cs2LiYCl6:Ce (CLYC) scintillator was measured with the SiPM and compared with two different PMT models: Bialkali and Superbialkali. The temperature sensitivity of the system CLYC + SiPM was measured from -10 to + 40°C. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
Aprile, E.; Agostini, F.; Alfonsi, M.; ...
2015-11-23
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, wemore » detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.« less
Status and prospects of the SNO+ experiment
NASA Astrophysics Data System (ADS)
Maneira, J.
2016-05-01
The SNO+ experiment is located at the SNOLAB underground laboratory and will employ 780 tons of liquid scintillator loaded, in its initial phase, with 800 kg of 130Te (0.3% by mass) for a low-background and high-isotope-mass search for neutrino-less double beta decay. SNO+ reuses the acrylic vessel and PMT array of the SNO detector, but several experimental upgrades and adaptations were necessary to allow for the use of liquid scintillator. The SNO+ technique allows a staged approach, and extensive R&D is ongoing to increase the loadings and improve the purification of Tellurium. The very good conditions of background and low energy threshold allow SNO+ to also have other physics topics in its program, including geo- and reactor neutrinos, Supernova and solar neutrinos. This talk will describe the main advantages and challenges of the SNO+ approach for the double-beta decay program, the current status of the experiment and its sensitivity prospects.
Agishev, Ravil
2018-05-10
This paper demonstrates a renewed concept and applications of the generalized methodology for atmospheric light detection and ranging (LIDAR) capability prediction as a continuation of a series of our previous works, where the dimensionless parameterization appeared as a tool for comparing systems of a different scale, design, and applications. The modernized concept applied to microscale and milliscale LIDARs with relatively new silicon photomultiplier detectors and traditional photomultiplier tube and avalanche photodiode detectors allowed prediction of the remote sensing instruments' performance and limitations. Such a generalized, uniform, and objective concept is applied for evaluation of the increasingly popular class of limited-energy LIDARs using the best optical detectors, operating on different targets (back-scatter or topographic, static or dynamic) and under intense sky background conditions. It can be used in the LIDAR community to compare different instruments and select the most suitable and effective ones for specific applications.
Silicon Photo-Multiplier Readouts for Scintillators in High-Energy Astronomy
NASA Technical Reports Server (NTRS)
Bloser, Peter F.; Legere, Jason S.; Bancroft, Christopher M.; McConnell, Mark L.; Ryan, James M.
2008-01-01
New scintillator materials have recently been shown to hold great potential for low-cost, reliable gamma-ray detectors in high-energy astronomy. New devices for the detection of scintillation light promise to make scintillator-based instruments even more attractive by reducing mass and power requirements,in particular, silicon photo-multipliers (SiPMs) are starting to become commercially available that offer gains and quantum efficiencies similar to those of photo-multiplier tubes (PMTs), but with greatly reduced mass, high ruggedness, low voltage requirements, and no sensitivity to magnetic fields. We have conducted laboratory tests of a sample of commercially available SiPMs coupled to LaBr3;Ce, a scintillator of relevance to to future high-energy astrophysics missions. We present results for gamma-ray spectroscopy. compare the SiPM performance to that of a PMT, and discuss the extent to which SiPMs offer significant advantages for scintillator-based space missions.
Emission from Crystals Irradiated with a Beam of Runaway Electrons
NASA Astrophysics Data System (ADS)
Buranchenko, A. G.; Tarasenko, V. F.; Beloplotov, D. V.; Baksht, E. Kh.
2018-01-01
An investigation of the spectral and amplitude-temporal characteristics of emission from different crystals, promising in terms of their application as detectors of runaway electrons, is performed. This emission is excited by subnanosecond electron beams generated in a gas diode. It is found out that at the electron energies of tens-hundreds of kiloelectronvolts, the main contribution into the emission from CsI, ZnS, type IIa artificial and natural diamonds, sapphire, CaF2, ZrO2, Ga2O3, CaCO3, CdS, and ZnSe crystals comes from the cathodoluminescence; the radiation pulse duration depends on the crystal used and sufficiently exceeds the Cherenkov radiation pulse duration. It is demonstrated that the latter radiation exhibits low intensity and can be detected in the short-wave region of the spectrum in the cases where a monochromator and a high-sensitivity photomultiplier tube (PMT) are used.
Quality Assurance on Undoped CsI Crystals for the Mu2e Experiment
Atanov, N.; Baranov, V.; Budagov, J.; ...
2017-12-21
The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm 3, and is readout by a large area silicon PMT array. A series of technical specifications was defined according to physics requirements. Preproduction CsI crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai Institute of Ceramics. We report the quality assurance on crystal's scintillation properties and their radiation hardness against ionization dose and neutrons. With a fast decay time of 30 ns and a light output of more than 100 p.e./MeVmore » measured with a bi-alkali PMT, undoped CsI crystals provide a cost-effective solution for the Mu2e experiment.« less
Protecting children from myopia: a PMT perspective for improving health marketing communications.
Lwin, May O; Saw, Seang-Mei
2007-01-01
This research examined the predictive utility of the protection motivation theory (PMT) model for myopia prevention amongst children. An integrative model for myopia prevention behavior of parents was first developed in the context of theory and survey instruments then refined using information gathered from two focus groups. Empirical data then was collected from parents of primary school children in Singapore, a country with one of the highest rates of myopia in the world, and analyzed using structural equation modeling (SEM). Our findings revealed that coping appraisal variables were more significantly associated with protection motivation, relative to threat appraisal variables. In particular, perceived self-efficacy was the strongest predictor of parental intention to enforce good visual health behaviors, while perceived severity was relatively weak. Health marketing communications and public policy implications are discussed.
NASA Astrophysics Data System (ADS)
Tiras, E.; Dilsiz, K.; Ogul, H.; Southwick, D.; Bilki, B.; Wetzel, J.; Nachtman, J.; Onel, Y.; Winn, D.
2016-10-01
Hamamatsu single anode R7761 and multi-anode R5900-00-M16 Photomultiplier Tubes have been characterized for use in a Secondary Emission (SE) Ionization Calorimetry study. SE Ionization Calorimetry is a novel technique to measure electromagnetic shower particles in extreme radiation environments. The different operation modes used in these tests were developed by modifying the conventional PMT bias circuit. These modifications were simple changes to the arrangement of the voltage dividers of the baseboard circuits. The PMTs with modified bases, referred to as operating in SE mode, are used as an SE detector module in an SE calorimeter prototype, and placed between absorber materials (Fe, Cu, Pb, W, etc.). Here, the technical design of different operation modes, as well as the characterization measurements of both SE modes and the conventional PMT mode are reported.
Quality Assurance on Undoped CsI Crystals for the Mu2e Experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Atanov, N.; Baranov, V.; Budagov, J.
The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm 3, and is readout by a large area silicon PMT array. A series of technical specifications was defined according to physics requirements. Preproduction CsI crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai Institute of Ceramics. We report the quality assurance on crystal's scintillation properties and their radiation hardness against ionization dose and neutrons. With a fast decay time of 30 ns and a light output of more than 100 p.e./MeVmore » measured with a bi-alkali PMT, undoped CsI crystals provide a cost-effective solution for the Mu2e experiment.« less
Demonstration of neutron detection utilizing open cell foam and noble gas scintillation
NASA Astrophysics Data System (ADS)
Lavelle, C. M.; Coplan, M.; Miller, E. C.; Thompson, Alan K.; Kowler, A. L.; Vest, Robert E.; Yue, A. T.; Koeth, T.; Al-Sheikhly, M.; Clark, Charles W.
2015-03-01
We present results demonstrating neutron detection via a closely spaced converter structure coupled to low pressure noble gas scintillation instrumented by a single photo-multiplier tube (PMT). The converter is dispersed throughout the gas volume using a reticulated vitreous carbon foam coated with boron carbide (B4C). A calibrated cold neutron beam is used to measure the neutron detection properties, using a thin film of enriched 10B as a reference standard. Monte Carlo computations of the ion energy deposition are discussed, including treatment of the foam random network. Results from this study indicate that the foam shadows a significant portion of the scintillation light from the PMT. The high scintillation yield of Xe appears to overcome the light loss, facilitating neutron detection and presenting interesting opportunities for neutron detector design.
Demonstration of neutron detection utilizing open cell foam and noble gas scintillation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lavelle, C. M., E-mail: christopher.lavelle@jhuapl.edu; Miller, E. C.; Coplan, M.
2015-03-02
We present results demonstrating neutron detection via a closely spaced converter structure coupled to low pressure noble gas scintillation instrumented by a single photo-multiplier tube (PMT). The converter is dispersed throughout the gas volume using a reticulated vitreous carbon foam coated with boron carbide (B{sub 4}C). A calibrated cold neutron beam is used to measure the neutron detection properties, using a thin film of enriched {sup 10}B as a reference standard. Monte Carlo computations of the ion energy deposition are discussed, including treatment of the foam random network. Results from this study indicate that the foam shadows a significant portionmore » of the scintillation light from the PMT. The high scintillation yield of Xe appears to overcome the light loss, facilitating neutron detection and presenting interesting opportunities for neutron detector design.« less
NASA Technical Reports Server (NTRS)
Moshchalcov, V. V.; Zhukov, A. A.; Kuznetzov, V. D.; Metlushko, V. V.; Leonyuk, L. I.
1990-01-01
At the initial time intervals, preceding the thermally activated flux creep regime, fast nonlogarithmic relaxation is found. The fully magnetic moment Pm(t) relaxation curve is shown. The magnetic measurements were made using SQUID-magnetometer. Two different relaxation regimes exist. The nonlogarithmic relaxation for the initial time intervals may be related to the viscous Abrikosov vortices flow with j is greater than j(sub c) for high enough temperature T and magnetic field induction B. This assumption correlates with Pm(t) measurements. The characteristic time t(sub O) separating two different relaxation regimes decreases as temperature and magnetic field are lowered. The logarithmic magnetization relaxation curves Pm(t) for fixed temperature and different external magnetic field inductions B are given. The relaxation rate dependence on magnetic field, R(B) = dPm(B, T sub O)/d(1nt) has a sharp maximum which is similar to that found for R(T) temperature dependences. The maximum shifts to lower fields as temperature goes up. The observed sharp maximum is related to a topological transition in shielding critical current distribution and, consequently, in Abrikosov vortices density. The nonlogarithmic magnetization relaxation for the initial time intervals is found. This fast relaxation has almost an exponentional character. The sharp relaxation rate R(B) maximum is observed. This maximum corresponds to a topological transition in Abrikosov vortices distribution.
Behavioral Interventions for Anger, Irritability, and Aggression in Children and Adolescents.
Sukhodolsky, Denis G; Smith, Stephanie D; McCauley, Spencer A; Ibrahim, Karim; Piasecka, Justyna B
2016-02-01
Anger, irritability, and aggression are among the most common reasons for child mental health referrals. This review is focused on two forms of behavioral interventions for these behavioral problems: Parent management training (PMT) and cognitive-behavioral therapy (CBT). First, we provide an overview of anger/irritability and aggression as the treatment targets of behavioral interventions, followed by a discussion of the general principles and techniques of these treatment modalities. Then we discuss our current work concerning the transdiagnostic approach to CBT for anger, irritability, and aggression. PMT is aimed at improving aversive patterns of family interactions that engender children's disruptive behavior. CBT targets deficits in emotion regulation and social problem-solving that are associated with aggressive behavior. Both forms of treatment have received extensive support in randomized controlled trials. Given that anger/irritability and aggressive behavior are common in children with a variety of psychiatric diagnoses, a transdiagnostic approach to CBT for anger and aggression is described in detail. PMT and CBT have been well studied in randomized controlled trials in children with disruptive behavior disorders, and studies of transdiagnostic approaches to CBT for anger and aggression are currently underway. More work is needed to develop treatments for other types of aggressive behavior (e.g., relational aggression) that have been relatively neglected in clinical research. The role of callous-unemotional traits in response to behavioral interventions and treatment of irritability in children with anxiety and mood disorders also warrants further investigation.
Behavioral Interventions for Anger, Irritability, and Aggression in Children and Adolescents
Smith, Stephanie D.; McCauley, Spencer A.; Ibrahim, Karim; Piasecka, Justyna B.
2016-01-01
Abstract Objective: Anger, irritability, and aggression are among the most common reasons for child mental health referrals. This review is focused on two forms of behavioral interventions for these behavioral problems: Parent management training (PMT) and cognitive-behavioral therapy (CBT). Methods: First, we provide an overview of anger/irritability and aggression as the treatment targets of behavioral interventions, followed by a discussion of the general principles and techniques of these treatment modalities. Then we discuss our current work concerning the transdiagnostic approach to CBT for anger, irritability, and aggression. Results: PMT is aimed at improving aversive patterns of family interactions that engender children's disruptive behavior. CBT targets deficits in emotion regulation and social problem-solving that are associated with aggressive behavior. Both forms of treatment have received extensive support in randomized controlled trials. Given that anger/irritability and aggressive behavior are common in children with a variety of psychiatric diagnoses, a transdiagnostic approach to CBT for anger and aggression is described in detail. Conclusions: PMT and CBT have been well studied in randomized controlled trials in children with disruptive behavior disorders, and studies of transdiagnostic approaches to CBT for anger and aggression are currently underway. More work is needed to develop treatments for other types of aggressive behavior (e.g., relational aggression) that have been relatively neglected in clinical research. The role of callous-unemotional traits in response to behavioral interventions and treatment of irritability in children with anxiety and mood disorders also warrants further investigation. PMID:26745682
Zare Sakhvidi, Mohammad Javad; Zare, Maryam; Mostaghaci, Mehrdad; Mehrparvar, Amir Houshang; Morowatisharifabad, Mohammad Ali; Naghshineh, Elham
2015-01-01
Backgrounds. The aim of this study was to describe the preventive behaviors of industrial workers and factors influencing occupational cancer prevention behaviors using protection motivation theory. Methods. A self-administered questionnaire was completed by 161 petrochemical workers in Iran in 2014 which consisted of three sections: background information, protection motivation theory measures, and occupational cancers preventive behaviors. Results. A statistically significant positive correlation was found between PM and self-efficacy, response efficacy, and the cancer preventive behaviors. Meanwhile, statistically significant negative correlations were found between PM, cost, and reward. Conclusions. Among available PMT constructs, only self-efficacy and cost were significant predictors of preventive behaviors. Protection motivation model based health promotion interventions with focus on self-efficacy and cost would be desirable in the case of occupational cancers prevention.
Zare Sakhvidi, Mohammad Javad; Zare, Maryam; Mehrparvar, Amir Houshang; Morowatisharifabad, Mohammad Ali; Naghshineh, Elham
2015-01-01
Backgrounds. The aim of this study was to describe the preventive behaviors of industrial workers and factors influencing occupational cancer prevention behaviors using protection motivation theory. Methods. A self-administered questionnaire was completed by 161 petrochemical workers in Iran in 2014 which consisted of three sections: background information, protection motivation theory measures, and occupational cancers preventive behaviors. Results. A statistically significant positive correlation was found between PM and self-efficacy, response efficacy, and the cancer preventive behaviors. Meanwhile, statistically significant negative correlations were found between PM, cost, and reward. Conclusions. Among available PMT constructs, only self-efficacy and cost were significant predictors of preventive behaviors. Protection motivation model based health promotion interventions with focus on self-efficacy and cost would be desirable in the case of occupational cancers prevention. PMID:26543649
Cardona, Jose Ruben Parra; Domenech-Rodriguez, Melanie; Forgatch, Marion; Sullivan, Cris; Bybee, Deborah; Holtrop, Kendal; Escobar-Chew, Ana Rocio; Tams, Lisa; Dates, Brian; Bernal, Guillermo
2011-01-01
Latinos constitute the largest ethnic minority group in the US. However, the cultural adaptation and dissemination of evidence-based parenting interventions among Latino populations continues to be scarce in spite of extensive research that demonstrates the long-term positive effects of these interventions. The purpose of this article is threefold: (a) justify the importance of cultural adaptation research as a key strategy to disseminate efficacious interventions among Latinos, (b) describe the initial steps of a program of prevention research with Latino immigrants aimed at culturally adapting an evidence-based intervention informed by parent management training (PMT) principles, and (c) discuss implications for advancing cultural adaptation prevention practice and research, based on the initial feasibility and cultural acceptability findings of the current investigation. PMID:22428711
Crosby, Priya; Hoyle, Nathaniel P; O'Neill, John S
2017-12-13
Luciferase-based reporters of cellular gene expression are in widespread use for both longitudinal and end-point assays of biological activity. In circadian rhythms research, for example, clock gene fusions with firefly luciferase give rise to robust rhythms in cellular bioluminescence that persist over many days. Technical limitations associated with photomultiplier tubes (PMT) or conventional microscopy-based methods for bioluminescence quantification have typically demanded that cells and tissues be maintained under quite non-physiological conditions during recording, with a trade-off between sensitivity and throughput. Here, we report a refinement of prior methods that allows long-term bioluminescence imaging with high sensitivity and throughput which supports a broad range of culture conditions, including variable gas and humidity control, and that accepts many different tissue culture plates and dishes. This automated longitudinal luciferase imaging gas- and temperature-optimized recorder (ALLIGATOR) also allows the observation of spatial variations in luciferase expression across a cell monolayer or tissue, which cannot readily be observed by traditional methods. We highlight how the ALLIGATOR provides vastly increased flexibility for the detection of luciferase activity when compared with existing methods.
E3 Success Story - Plastic Molding Technology, Inc.
Customer surveys prompted PMT to address new areas which included sustainability issues and reduction goals for energy, water and solid wastes; they were looking for a way to link their reduction projects into their system.
Light Yield Measurements of Heavy Photon Search (HPS) Muon Scintillator Hodoscopes
NASA Astrophysics Data System (ADS)
Skolnik, Marianne; Stepanyan, Stepan
2013-10-01
The HPS is an experiment that will search for new heavy vector boson(s) in the mass range of 20 MeV/c2 to 1000 MeV/c2. One of the detectors used for this experiment is a muon hodoscope. We are interested in finding the light yield for the scintillator - wavelength-shifting fiber coupling that will be used in this muon hodoscope. The muon hodoscope will have background signals distorting the data. In order to reduce the background, a threshold cut will be made on the signal coming from the photo-detector. Precision of this cut depends on the average number of photoelectrons, Npe. Previous tests have shown that Npe with Wavelength Shifting (WLS) fibers placed through the holes that go lengthwise down the scintillator is ~12/MeV. In this new muon hodoscope the scintillators will have WLS fibers glued inside the holes. The optical epoxy allows more light, changing Npe. To find Npe, two scintillators with fibers will be used, one of which will have glued WLS fibers. Light will be readout out using photo multiplier tubes (PMTs). The system of two scintillator-fiber-PMTs and one trigger PMT with a scintillator are placed in a dark box. First, position of a single photoelectron peaks is found using an LED light, then using the signal from cosmic muons from trigger PMT light yield is measured. Data are analyzed using ROOT macros. Result of this measurement suggests that light yield form glued fibers is higher than from WLS fibers without glue by a factor of ~1.7, which is sufficient for operation of the HPS muon hodoscope.
The Central Logic Board for the KM3NeT detector: Design and production
NASA Astrophysics Data System (ADS)
Musico, P.; KM3NeT Collaboration
2016-07-01
The KM3NeT deep sea neutrino observatory will include a very large number of multi-Photomultiplier (PMT) optical modules (DOM) to detect the Cherenkov light generated by secondary particles produced in neutrino interactions. The Central Logic Board (CLB) has been developed to acquire timing and amplitude information from the PMT signals, implementing time-to-digital conversion (TDC) with time over threshold (TOT) technique. The board is also used to configure all the DOM subsystems, to assist in the DOM position and orientation, calibration and to monitor temperature and humidity in the DOM itself. All the collected data are transmitted to shore using a wide-bandwidth optical network. Moreover, through the optical network, all the DOMs are kept synchronized in time within 1 ns precision using the White Rabbit (WR) Precision Time Protocol (PTP) over an Ethernet connection. A large Field Programmable Gate Array (FPGA) has been adopted to implement all the specifications witht the requested performances. The CLB will be also used in the base container of the detection unit (DU) to set-up and monitor all the requested functionalities: in this scenario a dedicated firmware and software will be deployed on board. The design has been started in early 2013 and several prototypes have been developed. After deep test carried on in different EU laboratories, the final mass production batch of 600 boards has been ordered and built: all the CLB are now ready for integration in the DOMs and base containers. The first two KM3NeT DU will be deployed in summer 2015 and all other units are in advanced stage of integration.
DOT National Transportation Integrated Search
2005-07-01
there were a number of problems and delays, by the time the year drew to a close implementation : was well underway, donor promises had been transformed into hard cash. Most importantly, new : recruits were joining the Program Management Team (PMT) g...
QUALITY ASSESSMENT OF CONFOCAL MICROSCOPY SLIDE-BASED SYSTEMS: INSTABLITY
Background: All slide-based fluorescence cytometry detections systems basically include an excitation light source, intermediate optics, and a detection device (CCD or PMT). Occasionally, this equipment becomes unstable, generating unreliable and inferior data. Methods: A num...
Wurtele, S K; Maddux, J E
1987-01-01
A factorial design was employed to test the relative effectiveness of the four cognitive appraisal processes (severity, vulnerability, response efficacy, and self-efficacy) contained in the revised protection motivation theory (PMT). One hundred sixty undergraduate women read persuasive appeals for increasing exercise, which varied on these four dimensions. As predicted, both the vulnerability and self-efficacy variables enhanced intentions to exercise along with similar effects on self-reported exercising. Intentions were predictive of self-reported changes in behavior. The obtained interaction between vulnerability, self-efficacy, and response efficacy suggests that individuals employed a "precaution strategy": They intended to adopt the recommended behavior even though they held weak beliefs about its effectiveness and were not convinced of their at-risk status. These findings are compared to others obtained using the PMT, and the issue of main and interactive effects produced by the model is also addressed.
Experimental light scattering by small particles: system design and calibration
NASA Astrophysics Data System (ADS)
Maconi, Göran; Kassamakov, Ivan; Penttilä, Antti; Gritsevich, Maria; Hæggström, Edward; Muinonen, Karri
2017-06-01
We describe a setup for precise multi-angular measurements of light scattered by mm- to μm-sized samples. We present a calibration procedure that ensures accurate measurements. Calibration is done using a spherical sample (d = 5 mm, n = 1.517) fixed on a static holder. The ultimate goal of the project is to allow accurate multi-wavelength measurements (the full Mueller matrix) of single-particle samples which are levitated ultrasonically. The system comprises a tunable multimode Argon-krypton laser, with 12 wavelengths ranging from 465 to 676 nm, a linear polarizer, a reference photomultiplier tube (PMT) monitoring beam intensity, and several PMT:s mounted radially towards the sample at an adjustable radius. The current 150 mm radius allows measuring all azimuthal angles except for ±4° around the backward scattering direction. The measurement angle is controlled by a motor-driven rotational stage with an accuracy of 15'.
Benítez, Alfredo; Santiago, Ulises; Sanchez, John E; Ponce, Arturo
2018-01-01
In this work, an innovative cathodoluminescence (CL) system is coupled to a scanning electron microscope and synchronized with a Raspberry Pi computer integrated with an innovative processing signal. The post-processing signal is based on a Python algorithm that correlates the CL and secondary electron (SE) images with a precise dwell time correction. For CL imaging, the emission signal is collected through an optical fiber and transduced to an electrical signal via a photomultiplier tube (PMT). CL Images are registered in a panchromatic mode and can be filtered using a monochromator connected between the optical fiber and the PMT to produce monochromatic CL images. The designed system has been employed to study ZnO samples prepared by electrical arc discharge and microwave methods. CL images are compared with SE images and chemical elemental mapping images to correlate the emission regions of the sample.
NASA Astrophysics Data System (ADS)
Benítez, Alfredo; Santiago, Ulises; Sanchez, John E.; Ponce, Arturo
2018-01-01
In this work, an innovative cathodoluminescence (CL) system is coupled to a scanning electron microscope and synchronized with a Raspberry Pi computer integrated with an innovative processing signal. The post-processing signal is based on a Python algorithm that correlates the CL and secondary electron (SE) images with a precise dwell time correction. For CL imaging, the emission signal is collected through an optical fiber and transduced to an electrical signal via a photomultiplier tube (PMT). CL Images are registered in a panchromatic mode and can be filtered using a monochromator connected between the optical fiber and the PMT to produce monochromatic CL images. The designed system has been employed to study ZnO samples prepared by electrical arc discharge and microwave methods. CL images are compared with SE images and chemical elemental mapping images to correlate the emission regions of the sample.
KTAG: The Kaon Identification Detector for CERN experiment NA62
NASA Astrophysics Data System (ADS)
Fry, J. R.; CERN NA62 Collaboration
2016-07-01
In the study of ultra-rare kaon decays, CERN experiment NA62 exploits an unseparated monochromatic (75 GeV/c) beam of charged particles of flux 800 MHz, of which 50 MHz are K+. Kaons are identified with more than 95% efficiency, a time resolution of better than 100 ps, and misidentification of less than 10-4 using KTAG, a differential, ring-focussed, Cherenkov detector. KTAG utilises 8 sets of 48 Hamamatsu PMTs, of which 32 are of type 9880 and 16 of type 7400, with signals fed directly to the differential inputs of NINO front-end boards and then to TDC cards within the TEL62 system. Leading and trailing edges of the PMT signal are digitised, enabling slewing corrections to be made, and a mean hit rate of 5 MHz per PMT is supported. The electronics is housed within a cooled and insulated Faraday cage with environmental monitoring capabilities.
Enhancing the Linear Dynamic Range in Multi-Channel Single Photon Detector beyond 7OD
Gudkov, Dmytro; Gudkov, George; Gorbovitski, Boris; Gorfinkel, Vera
2015-01-01
We present design, implementation, and characterization of a single photon detector based on 32-channel PMT sensor [model H7260-20, Hamamatsu]. The developed high speed electronics enables the photon counting with linear dynamic range (LDR) up to 108count/s per detector's channel. The experimental characterization and Monte-Carlo simulations showed that in the single photon counting mode the LDR of the PMT sensor is limited by (i) “photon” pulse width (current pulse) of 900ps and (ii) substantial decrease of amplitudes of current pulses for count rates exceeding 108 count/s. The multi-channel architecture of the detector and the developed firm/software allow further expansion of the dynamic range of the device by 32-fold by using appropriate beam shaping. The developed single photon counting detector was tested for the detection of fluorescence labeled microbeads in capillary flow. PMID:27087788
Review of clinical studies of Polygonum multiflorum Thunb. and its isolated bioactive compounds
Bounda, Guy-Armel; Feng, YU
2015-01-01
Polygonum multiflorum Thunb. (PMT), officially listed in the Chinese Pharmacopoeia, is one of the most popular perennial Chinese traditional medicines known as He shou wu in China and East Asia, and as Fo-ti in North America. Mounting pharmacological studies have stressed out its key benefice for the treatment of various diseases and medical conditions such as liver injury, cancer, diabetes, alopecia, atherosclerosis, and neurodegenerative diseases as well. International databases such as PubMed/Medline, Science citation Index and Google Scholar were searched for clinical studies recently published on P. multiflorum. Various clinical studies published articles were retrieved, providing information relevant to pharmacokinetics-pharmacodynamics analysis, sleep disorders, dyslipidemia treatment, and neurodegenerative diseases. This review is an effort to update the clinical picture of investigations ever carried on PMT and/or its isolated bio-compounds and to enlighten its therapeutic assessment. PMID:26130933
Evaluation of confocal microscopy system performance.
Zucker, R M; Price, O
2001-08-01
The confocal laser scanning microscope (CLSM) has been used by scientists to visualize three-dimensional (3D) biological samples. Although this system involves lasers, electronics, optics, and microscopes, there are few published tests that can be used to assess the performance of this equipment. Usually the CLSM is assessed by subjectively evaluating a biological/histological test slide for image quality. Although there is a use for the test slide, there are many other components in the CLSM that need to be assessed. It would be useful if tests existed that produced reference values for machine performance. The aim of this research was to develop quality assurance tests to ensure that the CLSM was stable while delivering reproducible intensity measurements with excellent image quality. Our ultimate research objective was to quantify fluorescence using a CLSM. To achieve this goal, it is essential that the CLSM be stable while delivering known parameters of performance. Using Leica TCS-SP1 and TCS-4D systems, a number of tests have been devised to evaluate equipment performance. Tests measuring dichroic reflectivity, field illumination, lens performance, laser power output, spectral registration, axial resolution, laser stability, photomultiplier tube (PMT) reliability, and system noise were either incorporated from the literature or derived in our laboratory to measure performance. These tests are also applicable to other manufacturer's systems with minor modifications. A preliminary report from our laboratory has addressed a number of the QA issues necessary to achieve CLSM performance. This report extends our initial work on the evaluation of CLSM system performance. Tests that were described previously have been modified and new tests involved in laser stability and sensitivity are described. The QA tests on the CLSM measured laser power, PMT function, dichroic reflection, spectral registration, axial registration, system noise and sensitivity, lens performance, and laser stability. Laser power stability varied between 3% and 30% due to various factors, which may include incompatibility of the fiber-optic polarization with laser polarization, thermal instability of the acoustical optical transmission filter (AOTF), and laser noise. The sensitivity of the system was measured using a 10-microm Spherotech bead and the PMTs were assessed with the CV concept (image noise). The maximum sensitivity obtainable on our TCS-SP1 system measured on the 10-microm Spherotech beads was approximately 4% for 488 nm, 2.5% for 568 nm, 20% for 647 nm, and 19% for 365 nm laser light. The values serve as a comparison to test machine sensitivity from the same or different manufacturers. QA tests are described on the CLSM to assess performance and ensure that reproducing data are obtained. It is suggested strongly that these tests be used in place of a biological/histological sample to evaluate system performance. The tests are more specific and can recognize instrument functionality and problems better than a biological/histological sample. Utilization of this testing approach will eliminate the subjective assessment of the CLSM and may allow the data from different machines to be compared. These tests are essential if one is interested in making intensity measurements on experimental samples as well as obtaining the best signal detection and image resolution from a CLSM. Published 2001 Wiley-Liss, Inc.
Development of a new type of germanium detector for dark matter searches
NASA Astrophysics Data System (ADS)
Wei, Wenzhao
Monte Carlo simulation is an important tool used to develop a better understanding of important physical processes. This thesis describes three Monte Carlo simulations used to understand germanium detector response to low energy nuclear recoils and radiogenic backgrounds for direct dark matter searches. The first simulation is the verification of Barker-Mei model, a theoretical model for calculating the ionization efficiency for germanium detector for the energy range of 1 - 100 keV. Utilizing the shape analysis, a bin-to-bin comparison between simulation and experimental data was performed for verifying the accuracy of the Barker-Mei model. A percentage difference within 4% was achieved between data and simulation, which showed the validity of the Barker-Mei model. The second simulation is the study of a new type of germanium detector for n/gamma discrimination at 77 K with plasma time difference in pulse shape. Due to the poor time resolution, conventional P-type Point Contact (PPC) and coaxial germanium detectors are not capable of discriminating nuclear recoils from electron recoils. In this thesis, a new idea of using great detector granularity and plasma time difference in pulse shape to discriminate nuclear recoils from electron recoils with planar germanium detectors in strings was discussed. The anticipated sensitivity of this new detector array is shown for detecting dark matter. The last simulation is a study of a new type of germanium-detector array serving as a PMT screening facility for ultra-low background dark matter experiments using noble liquid xenon as detector material such LUX/LZ and XENON100/XENON1T. A well-shaped germanium detector array and a PMT were simulated to study the detector response to the signal and background for a better understanding of the radiogenic gamma rays from PMTs. The detector efficiency and other detector performance were presented in this work.
Gu, Can; Chan, Carmen W H; Twinn, Sheila; Choi, Kai Chow
2012-12-01
Theories of health behavior and empirical research highlight the risk perception as a significant factor for people adopting cancer screening. However, screening uptakes and risk perception of cervical cancer in mainland Chinese women remains unknown. This paper adopted the protection motivation theory (PMT) to examine Chinese women's knowledge and perceptions of cervical cancer risk and factors influencing utilization of cervical screening. A self-administered questionnaire was completed by 167 participants in mainland China (79 nonscreened and 88 screened women) in 2007 which consisted of four sections: background information, women's attendance pattern for cervical screening, perceptions related to body health and knowledge about cervical cancer and screening, and PMT measures. All women considered themselves at low risk of cervical cancer. No significant association was observed between previous screening uptake and PMT variables. Using multivariate analysis, having children, a perception that visiting doctors regularly is important to health, average and high levels of knowledge about cervical screening were significantly associated with having been received screening. Chinese women demonstrated an unrealistic optimism about their personal risk of cervical cancer. The findings do not support an association between risk perception and screening uptake. In spite of this, current findings revealed some possible factors influencing women's screening behavior. This study highlights the significance of knowledge and culturally-relevant health behavior and beliefs about cervical screening for Chinese women in determining whether or not they receive screening. The promotion of cervical cancer prevention and early detection should be integrated into public education about women's health. Copyright © 2011 John Wiley & Sons, Ltd.
Mok, Yingting; Lee, Jen-Chieh; Lum, Jeffrey Huey Yew; Petersson, Fredrik
2016-05-01
Phosphaturic mesenchymal tumour (PMT) is a rare, recently described neoplastic entity. It is characterized by distinct histological features, which often occur together with oncogenic osteomalacia. Recently, a novel FN1-FGFR1 gene fusion has been described in a subset of PMTs. The aim of this study is to characterise the clinicopathological features of two PMTs, with FGFR1 immunohistochemical and cytogenetic analyses. We present two contrasting cases of PMT, one occurring in the sinonasal region, and the other occurring in bone (proximal femur). In the former, local effects, including epistaxis and anosmia, dominated the clinical presentation, whereas the latter case presented with refractory bone pain, muscle weakness, and occult osteomalacia, the cause of which was only identified after 2 years. Both tumours showed characteristic histological features of PMT, including a monomorphic proliferation of round to ovoid cells, osteoclast-like multinucleated giant cells, and areas of 'smudgy' basophilic calcifications. Chromogenic in-situ hybridization showed fibroblast growth factor FGF-23 expression by the sinonasal tumour. By using immunohistochemistry, we also demonstrated, for the first time, FGF receptor 1 (FGFR1) protein overexpression in this tumour, for which FN1-FGFR1 gene fusion was not detected by fluorescence in-situ hybridization. Our findings indicate that up-regulation of FGFR1 in phosphaturic mesenchymal tumours can occur via mechanisms other than FN1-FGFR1 fusion, raising the possibility of FGFR1 overexpression being a potential common pathway with pathophysiological and therapeutic implications. © 2015 John Wiley & Sons Ltd.
Evaluation of FEM engineering parameters from insitu tests
DOT National Transportation Integrated Search
2001-12-01
The study looked critically at insitu test methods (SPT, CPT, DMT, and PMT) as a means for developing finite element constitutive model input parameters. The first phase of the study examined insitu test derived parameters with laboratory triaxial te...
Qin, Heng; Zuo, Yong; Zhang, Dong; Li, Yinghui; Wu, Jian
2017-03-06
Through slight modification on typical photon multiplier tube (PMT) receiver output statistics, a generalized received response model considering both scattered propagation and random detection is presented to investigate the impact of inter-symbol interference (ISI) on link data rate of short-range non-line-of-sight (NLOS) ultraviolet communication. Good agreement with the experimental results by numerical simulation is shown. Based on the received response characteristics, a heuristic check matrix construction algorithm of low-density-parity-check (LDPC) code is further proposed to approach the data rate bound derived in a delayed sampling (DS) binary pulse position modulation (PPM) system. Compared to conventional LDPC coding methods, better bit error ratio (BER) below 1E-05 is achieved for short-range NLOS UVC systems operating at data rate of 2Mbps.
Methods for estimating bicycling and walking in Washington state.
DOT National Transportation Integrated Search
2014-05-01
This report presents the work performed in the first and second phases in the process of creating a method to : calculate Bicycle and Pedestrian Miles Traveled (BMT/PMT) for the state of Washington. First, we recommend : improvements to the existing ...
Position reconstruction in LUX
NASA Astrophysics Data System (ADS)
Akerib, D. S.; Alsum, S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Brás, P.; Byram, D.; Cahn, S. B.; Carmona-Benitez, M. C.; Chan, C.; Currie, A.; Cutter, J. E.; Davison, T. J. R.; Dobi, A.; Druszkiewicz, E.; Edwards, B. N.; Fallon, S. R.; Fan, A.; Fiorucci, S.; Gaitskell, R. J.; Genovesi, J.; Ghag, C.; Gilchriese, M. G. D.; Hall, C. R.; Hanhardt, M.; Haselschwardt, S. J.; Hertel, S. A.; Hogan, D. P.; Horn, M.; Huang, D. Q.; Ignarra, C. M.; Jacobsen, R. G.; Ji, W.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Knoche, R.; Larsen, N. A.; Lenardo, B. G.; Lesko, K. T.; Lindote, A.; Lopes, M. I.; Manalaysay, A.; Mannino, R. L.; Marzioni, M. F.; McKinsey, D. N.; Mei, D.-M.; Mock, J.; Moongweluwan, M.; Morad, J. A.; Murphy, A. St. J.; Nehrkorn, C.; Nelson, H. N.; Neves, F.; O'Sullivan, K.; Oliver-Mallory, K. C.; Palladino, K. J.; Pease, E. K.; Rhyne, C.; Shaw, S.; Shutt, T. A.; Silva, C.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Sumner, T. J.; Szydagis, M.; Taylor, D. J.; Taylor, W. C.; Tennyson, B. P.; Terman, P. A.; Tiedt, D. R.; To, W. H.; Tripathi, M.; Tvrznikova, L.; Uvarov, S.; Velan, V.; Verbus, J. R.; Webb, R. C.; White, J. T.; Whitis, T. J.; Witherell, M. S.; Wolfs, F. L. H.; Xu, J.; Yazdani, K.; Young, S. K.; Zhang, C.
2018-02-01
The (x, y) position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional form to account for the photons reflected on the inner walls of the detector. To increase the resolution for small pulses, a photon counting technique was employed to describe the response of the PMTs. The reconstruction was assessed with calibration data including 83mKr (releasing a total energy of 41.5 keV) and 3H (β- with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron beam (2.45 MeV) . Within the detector's fiducial volume, the reconstruction has achieved an (x, y) position uncertainty of σ = 0.82 cm and σ = 0.17 cm for events of only 200 and 4,000 detected electroluminescence photons respectively. Such signals are associated with electron recoils of energies ~0.25 keV and ~10 keV, respectively. The reconstructed position of the smallest events with a single electron emitted from the liquid surface (22 detected photons) has a horizontal (x, y) uncertainty of 2.13 cm.
Life-cycle environmental inventory of passenger transportation modes in the United States
NASA Astrophysics Data System (ADS)
Chester, Mikhail Vin
To appropriately mitigate environmental impacts from transportation, it is necessary for decision makers to consider the life-cycle energy consumption and emissions associated with each mode. A life-cycle energy, greenhouse gas, and criteria air pollutant emissions inventory is created for the passenger transportation modes of automobiles, urban buses, heavy rail transit, light rail transit, and aircraft in the U.S. Each mode's inventory includes an assessment of vehicles, infrastructure, and fuel components. For each component, analysis is performed for material extraction through use and maintenance in both direct and indirect (supply chain) processes. For each mode's life-cycle components, energy inputs and emission outputs are determined. Energy inputs include electricity and petroleum-based fuels. Emission outputs include greenhouse gases (CO2, CH4, and N2O) and criteria pollutants (CO, SO2, NOx , VOCs, and PM). The inputs and outputs are normalized by vehicle lifetime, vehicle mile traveled, and passenger mile traveled. A consistent system boundary is applied to all modal inventories which captures the entire life-cycle, except for end-of-life. For each modal life-cycle component, both direct and indirect processes are included if possible. A hybrid life-cycle assessment approach is used to estimate the components in the inventories. We find that life-cycle energy inputs and emission outputs increase significantly compared to the vehicle operational phase. Life-cycle energy consumption is 39-56% larger than vehicle operation for autos, 38% for buses, 93-160% for rail, and 19-24% for air systems per passenger mile traveled. Life-cycle greenhouse gas emissions are 47-65% larger than vehicle operation for autos, 43% for buses, 39-150% for rail, and 24-31% for air systems per passenger mile traveled. The energy and greenhouse gas increases are primarily due to vehicle manufacturing and maintenance, infrastructure construction, and fuel production. For criteria air pollutants, life-cycle components often dominate total emissions and can be a magnitude larger than operational counterparts. Per passenger mile traveled, total SO2 emissions (between 350 and 460 mg) are 19-27 times larger than operational emissions as a result of electricity generation in vehicle manufacturing, infrastructure construction, and fuel production. NOx emissions increase 50-73% for automobiles, 24% for buses, 13-1300% for rail, and 19-24% for aircraft. Non-tailpipe VOCs are 27-40% of total automobile, 71-95% of rail, and 51-81% of air total emissions. Infrastructure and parking construction are major components of total PM10 emissions resulting in total emissions over three times larger than operational emissions for autos and even larger for many rail systems and aircraft (the major contributor being emissions from hot-mix asphalt plants and concrete production). Infrastructure construction and operation as well as vehicle manufacturing increase total CO emissions by 5-17 times from tailpipe performance for rail and 3-9 times for air. A case study comparing the environmental performance of metropolitan regions is presented as an application of the inventory results. The San Francisco Bay Area, Chicago, and New York City are evaluated capturing passenger transportation life-cycle energy inputs and greenhouse gas and criteria air pollutant emissions. The regions are compared between off-peak and peak travel as well as personal and public transit. Additionally, healthcare externalities are computed from vehicle emissions. It is estimated that life-cycle energy varies from 6.3 MJ/PMT in the Bay Area to 5.7 MJ/PMT in Chicago and 5.3 MJ/PMT in New York for an average trip. Life-cycle GHG emissions range from 480 g CO2e/PMT in the Bay Area to 440 g CO2e/PMT for Chicago and 410 g CO 2e/PMT in New York. CAP emissions vary depending on the pollutant with differences as large as 25% between regions. Life-cycle CAP emissions are between 11% and 380% larger than their operational counterparts. Peak travel, with typical higher riderships, does not necessarily environmentally outperform off-peak travel due to the large share of auto PMT and less than ideal operating conditions during congestion. The social costs of travel range from ¢51 (in ¢2007) per auto passenger per trip during peak in New York to ¢6 per public transit passenger per trip during peak hours in the Bay Area and New York. Average personal transit costs are around ¢30 while public transit ranges from ¢28 to ¢41. (Abstract shortened by UMI.)
Tn4556, a 6.8-kilobase-pair transposable element of Streptomyces fradiae.
Chung, S T
1987-01-01
A 6.8-kilobase-pair (kbp) transposable element (Tn4556) was found in a neomycin-producing strain of Streptomyces fradiae. This element was first observed in two 30.3-kbp plasmids (pUC1123 and pUC1124) which arose when a thiostrepton resistance gene (1 kbp) was ligated with the BclI-2 fragment (22.5 kbp) that contains the origin of replication of phage SF1. The Tn4556 segment was deleted when these plasmids were transduced into another S. fradiae host with phage SF1. These deletion plasmids (pUC1210 and pUC1211) had copy numbers of less than 1 per chromosome and were unstable. In contrast, pUC1123 and pUC1124, with copy numbers of 12 to 15 per chromosome, respectively, were relatively stable. When pUC1210 and pUC1211 were reintroduced into S. fradiae by protoplast transformation, the Tn4556 element transposed again to the plasmids at numerous new locations in either of two orientations. A copy of Tn4556 was found in the S. fradiae chromosome by hybridization studies. It appears that Tn4556 originated from the chromosome, transposed into unstable pUC1210 and pUC1211, and made stable plasmids. A temperature-sensitive hybrid plasmid carrying a viomycin resistance derivative of Tn4556 (pMT660::Tn4556::vph) was constructed. When Streptomyces lividans UC8390 containing the hybrid plasmid was grown at 39 degrees C, Tn4556::vph (Tn4560) transposed to random positions in the host chromosome. Images PMID:2820925
Geng, Xuhui; Shi, Meng; Ning, Haijing; Feng, Chunbo; Guan, Yafeng
2018-05-15
A compact and low-cost laser induced fluorescence (LIF) detector based on confocal structure for capillary flow systems was developed and applied for analysis of Her2 protein on single Hela cells. A low-power and low-cost 450 nm laser diode (LD) instead of a high quality laser was used as excitation light source. A compact optical design together with shortened optical path length improved the optical efficiency and detection sensitivity. A superior silicon based photodetector assembly was used for fluorescence detection instead of a photomultiplier (PMT). The limit of detection (LOD) for fluorescein sodium was 3 × 10 -12 M or 165 fluorescein molecules in detection volume measured on a homemade capillary electroosmotic driven (EOD)-LIF system, which was similar to commercial LIFs. Compared to commercial LIFs, the whole volume of our LIF was reduced to 1/2-1/3, and the cost was less than 1/3 of them. Copyright © 2018 Elsevier B.V. All rights reserved.
Towards Optical Partial Discharge Detection with Micro Silicon Photomultipliers
Ren, Ming; Song, Bo; Dong, Ming
2017-01-01
Optical detection is reliable in intrinsically characterizing partial discharges (PDs). Because of the great volume and high-level power supply of the optical devices that can satisfy the requirements in photosensitivity, optical PD detection can merely be used in laboratory studies. To promote the practical application of the optical approach in an actual power apparatus, a silicon photomultiplier (SiPM)-based PD sensor is introduced in this paper, and its basic properties, which include the sensitivity, pulse resolution, correlation with PD severity, and electromagnetic (EM) interference immunity, are experimentally evaluated. The stochastic phase-resolved PD pattern (PRPD) for three typical insulation defects are obtained by SiPM PD detector and are compared with those obtained using a high-frequency current transformer (HFCT) and a vacuum photomultiplier tube (PMT). Because of its good performances in the above aspects and its additional advantages, such as the small size, low power supply, and low cost, SiPM offers great potential in practical optical PD monitoring. PMID:29125544
Towards Optical Partial Discharge Detection with Micro Silicon Photomultipliers.
Ren, Ming; Zhou, Jierui; Song, Bo; Zhang, Chongxing; Dong, Ming; Albarracín, Ricardo
2017-11-10
Optical detection is reliable in intrinsically characterizing partial discharges (PDs). Because of the great volume and high-level power supply of the optical devices that can satisfy the requirements in photosensitivity, optical PD detection can merely be used in laboratory studies. To promote the practical application of the optical approach in an actual power apparatus, a silicon photomultiplier (SiPM)-based PD sensor is introduced in this paper, and its basic properties, which include the sensitivity, pulse resolution, correlation with PD severity, and electromagnetic (EM) interference immunity, are experimentally evaluated. The stochastic phase-resolved PD pattern (PRPD) for three typical insulation defects are obtained by SiPM PD detector and are compared with those obtained using a high-frequency current transformer (HFCT) and a vacuum photomultiplier tube (PMT). Because of its good performances in the above aspects and its additional advantages, such as the small size, low power supply, and low cost, SiPM offers great potential in practical optical PD monitoring.
Development of an Abort Gap Monitor for High-Energy Proton Rings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beche, J.-F.; Byrd, J.; De Santis, S.
2004-11-10
The fill pattern in proton synchrotrons usually features an empty gap, longer than the abort kicker raise time, for machine protection. This gap is referred to as the 'abort gap', and any particles, which may accumulate in it due to injection errors and diffusion between RF buckets, would be lost inside the ring, rather than in the beam dump, during the kicker firing. In large proton rings, due to the high energies involved, it is vital to monitor the build up of charges in the abort gap with a high sensitivity. We present a study of an abort gap monitormore » based on a photomultiplier with a gated microchannel plate, which would allow for detecting low charge densities by monitoring the synchrotron radiation emitted. We show results of beam test experiments at the Advanced Light Source using a Hamamatsu 5916U MCP-PMT and compare them to the specifications for the Large Hadron Collider.« less
Development of an abort gap monitor for high-energy proton rings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beche, Jean-Francois; Byrd, John; De Santis, Stefano
2004-05-03
The fill pattern in proton synchrotrons usually features an empty gap, longer than the abort kicker raise time, for machine protection. This gap is referred to as the ''abort gap'' and any particles, which may accumulate in it due to injection errors and diffusion between RF buckets, would be lost inside the ring, rather than in the beam dump, during the kicker firing. In large proton rings, due to the high energies involved, it is vital to monitor the build up of charges in the abort gap with a high sensitivity. We present a study of an abort gap monitormore » based on a photomultiplier with a gated microchannel plate, which would allow for detecting low charge densities by monitoring the synchrotron radiation emitted. We show results of beam test experiments at the Advanced Light Source using a Hamamatsu 5916U MCP-PMT and compare them to the specifications for the Large Hadron Collider« less
Mirkarimi, Kamal; Mostafavi, Firoozeh; Eshghinia, Samira; Vakili, Mohammad Ali; Ozouni-Davaji, Rahman Berdi; Aryaie, Mohammad
2015-06-01
The prevalence of overweight and obesity is on the increase the world over, which imposes an ever-increasing burden on societies and health care systems. This study sought to investigate the effect of motivational interviewing (MI) on a weight-loss program based on the protection motivation theory (PMT). This randomized clinical trial study, comprising pretest-posttest with a control group, was conducted on 150 overweight and obese women attending a private nutrition clinic for the first time. Samples were randomly selected using the clinic's records and then allocated to three groups (50 women in each group) receiving: 1) a standard weight-control program; 2) motivational interviewing; and 3) MI plus intention intervention. Data were collected using a researcher-made questionnaire through in-person interviews and were analyzed using SPSS (version 11) and statistical tests, including the Kruskal-Wallis test, one-way analysis of variance, paired t-test, and linear regression model. In the two intervention groups, the PMT construct scores, namely susceptibility (P = 0.001), severity (P = 0.001), rewards (P =0.004), self-efficacy (P = 0.001), response efficacy (P = 0.001), and costs (P = 0.014), were significantly increased compared to those in the control group. The anthropometric status was statistically significant in the MI group (P = 0.001) and the MI plus intention-intervention group (P = 0.001) at 2 months' follow-up, while in the control group, weight was meaningfully different after the intervention (P = 0.027). Weight was different between the groups after the intervention, with the Tukey test demonstrating that the differences were statistically significant between the control group and the MI group. Our results demonstrated that MI, combined with the implementation of intention intervention, increased weight loss and PMT construct scores in our study population.
Philip, Bevin; Levin, David E.
2001-01-01
Wsc1 and Mid2 are highly O-glycosylated cell surface proteins that reside in the plasma membrane of Saccharomyces cerevisiae. They have been proposed to function as mechanosensors of cell wall stress induced by wall remodeling during vegetative growth and pheromone-induced morphogenesis. These proteins are required for activation of the cell wall integrity signaling pathway that consists of the small G-protein Rho1, protein kinase C (Pkc1), and a mitogen-activated protein kinase cascade. We show here by two-hybrid experiments that the C-terminal cytoplasmic domains of Wsc1 and Mid2 interact with Rom2, a guanine nucleotide exchange factor (GEF) for Rho1. At least with regard to Wsc1, this interaction is mediated by the Rom2 N-terminal domain. This domain is distinct from the Rho1-interacting domain, suggesting that the GEF can interact simultaneously with a sensor and with Rho1. We also demonstrate that extracts from wsc1 and mid2 mutants are deficient in the ability to catalyze GTP loading of Rho1 in vitro, providing evidence that the function of the sensor-Rom2 interaction is to stimulate nucleotide exchange toward this G-protein. In a related line of investigation, we identified the PMT2 gene in a genetic screen for mutations that confer an additive cell lysis defect with a wsc1 null allele. Pmt2 is a member of a six-protein family in yeast that catalyzes the first step in O mannosylation of target proteins. We demonstrate that Mid2 is not mannosylated in a pmt2 mutant and that this modification is important for signaling by Mid2. PMID:11113201
Gritti, Fabrice
2017-02-17
Superficially porous particles (SPPs) can be prepared from a pseudomorphic transformation (PMT) which produces straight, unconnected, and radially-oriented mesopores (ROMs). ROMs can be either both ends open in fully porous particles (FPPs) or one-end-closed in SPPs. The impact of ROMs on the longitudinal diffusion (B/u), solid-liquid mass transfer resistance (C s u), and on the eddy dispersion (A(u)) height equivalent to a theoretical plate (HETP) of 3D randomly packed columns was investigated based on theoretical viewpoints. Torquato's theory of effective diffusion in packed beds (B term), Giddings' coupling theory of eddy dispersion (A term), and Giddings' generalized nonequilibrium theory (C s term) are applied to make predictions. First, it is found that the A term is nearly independent on the internal structure of the particle. Secondly, in the absence of flow, infinitely narrow and both ends open (no constriction effect) ROMs induce an internal hindrance factor of 23 regarding diffusion along the axial direction. Experimental data reveal that one-end-closed and 80Å wide ROMs in SPPs lead to a measurable internal hindrance factor of 27 regarding diffusion in the porous shell. Thirdly, above the optimum speed, the C s coefficient is dependent on the geometry (cylinders, cones, etc.) of the ROMs: when ROMs are conical in SPPs, C s is expected to decrease by 80% with respect to cylindrical ROMs. From an application perspective, PMT-SPPs prepared with narrow ROMs are well suited for the analysis of small molecules at or below optimum speed (lowest B term) while PMT-SPPs made of wide and conical ROMs are ideal for the analysis of large molecules above optimum speed (smallest C s term). Copyright © 2017. Published by Elsevier B.V.
Lifetime of MCP-PMTs and other performance features
NASA Astrophysics Data System (ADS)
Lehmann, A.; Böhm, M.; Eyrich, W.; Miehling, D.; Pfaffinger, M.; Stelter, S.; Uhlig, F.; Ali, A.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Düren, M.; Etzelmüller, E.; Föhl, K.; Hayrapetyan, A.; Kreutzfeld, K.; Merle, O.; Rieke, J.; Schmidt, M.; Wasem, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.
2018-02-01
The bar PANDA experiment at FAIR will use DIRC detectors for the separation of hadrons. The compactness of the bar PANDA detector requires the image planes of these detectors to be placed inside the magnetic field of the solenoid. Due to this and other boundary conditions MCP-PMTs were identified as the only suitable photon sensors. Until recently the major obstacle for an application of MCP-PMTs in high rate experiments like bar PANDA were serious aging problems which led to damage at the photo-cathode and a fast declining quantum efficiency as the integrated anode charge (IAC) increased. With new countermeasures against the aging, in particular due to the application of an atomic layer deposition (ALD) technique to coat the MCP pores, the lifetime of MCP-PMTs has meanwhile increased by a factor >50 which is fully sufficient for bar PANDA. The recent results of our long-term lifetime measurements are discussed. New 2-inch MCP-PMT prototypes from Hamamatsu show an encouraging behavior. However, the currently best performing MCP-PMT is a 2-inch PHOTONIS tube with two ALD-layers which reaches an IAC of >16 C/cm2 without any visible sign of aging. In the second part of these proceedings a new data acquisition system of the PADIWA/TRB type is presented which allows a quasi-parallel measurement of many MCP-PMT performance parameters. Especially unwanted effects like dark-count rate, crosstalk, ion after-pulsing, and recoil electrons can be studied in more detail than ever before. Exemplary results for these parameters are shown. The discussed DAQ system will be used for the comprehensive data quality checks of the MCP-PMTs being built into the DIRCs.
NaI(Tl) scintillator read out with SiPM array for gamma spectrometer
NASA Astrophysics Data System (ADS)
Huang, Tuchen; Fu, Qibin; Lin, Shaopeng; Wang, Biao
2017-04-01
The NaI(Tl) scintillator is widely used in gamma spectrometer with photomultiplier tube (PMT) readout. Recently developed silicon photomultiplier (SiPM) offers gain and efficiency similar to those of PMT, but with merits such as low bias voltage, compact volume, low cost, high ruggedness and magnetic resonance compatibility. In this study, 2-in. and 1-in. NaI(Tl) scintillators were readout with SiPM arrays, which were made by tiling multiple SiPMs each with an active area of 6×6 mm2 on a printed circuit board. The energy resolutions for 661.6 keV gamma rays, obtained with Φ2×2 in. scintillator coupled to 6×6 ch SiPM array and Φ1×1 in. scintillator coupled to 4×4 ch SiPM array were 7.6% and 7.8%, respectively, and were very close to the results obtained with traditional bialkali PMT (7.3% and 7.6%, respectively). Scintillator coupled to photodetector with smaller area was also studied by adding a light guide or using scintillator with tapered head. The latter showed better performance than using light guide. The 1-in. NaI(Tl) scintillator with tapered head coupled to 2×2 ch SiPM array achieved 7.7% energy resolution at 661.6 keV, the same as that obtained with standard Φ1×1 in. scintillator coupled to 4×4 ch SiPM array. While the 2-in. scintillator with similar geometry showed degraded energy resolution, 10.2% at 661.6 keV, but could still be used when high efficiency is preferred over energy resolution.
Xiao, Han; Peng, Minjin; Yan, Hong; Gao, Mengting; Li, Jingjing; Yu, Bin; Wu, Hanbo; Li, Shiyue
2016-01-01
Further advancement in schistosomiasis prevention requires new tools to assess protective motivation, and promote innovative intervention program. This study aimed to develop and evaluate an instrument developed based on the Protection Motivation Theory (PMT) to predict protective behavior intention against schistosomiasis among adolescents in China. We developed the Schistosomiasis PMT Scale based on two appraisal pathways of protective motivation- threat appraisal pathway and coping appraisal pathway. Data from a large sample of middle school students ( n = 2238, 51 % male, mean age 13.13 ± 1.10) recruited in Hubei, China was used to evaluated the validity and reliability of the scale. The final scale contains 18 items with seven sub-constructs. Cronbach's Alpha coefficients for the entire instrument was 0.76, and for the seven sub-constructs of severity, vulnerability, intrinsic reward, extrinsic reward, response efficacy, self-efficacy and response cost was 0.56, 0.82, 0.75, 0.80, 0.90, 0.72 and 0.70, respectively. The construct validity analysis revealed that the one level 7 sub-constructs model fitted data well (GFI = 0.98, CFI = 0.98, RMSEA = 0.03, Chi-sq/df = 3.90, p < 0.001). Predictive validity showed that both the PMT instrument score and the 7 sub-construct scores were significantly correlated with the intention engaged in protective behavior against schistosomiasis ( p < 0.05). This study provides a reliable and valid tool to measure protective motivation in schistosomiasis prevention control. Further studies are needed to develop more effective intervention programs for schistosomiasis prevention.
An evaluation of the utility of four in situ test methods for transmission line foundation design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mullen, W.G. Jr.
1991-01-01
This research examines four existing in-situ soil strength testing methods; standard penetration test (SPT), the cone penetrometer (CPT), the flat plate dilatometer (DMT), and the pressuremeter (PMT). Soils data were collected at eight separate sites using each of the devices. The test sites were chosen to mirror soil conditions encountered within the service territory of Virginia Power, the project sponsor. A total of 19 standard soil borings, 30 cone penetrometer soundings, 26 dilatometer soundings, and 33 pressuremeter tests were undertaken in residual, alluvial and marine clay soil conditions. The testing program was conducted with five areas of concern: (1) comparisonmore » of the penetration/stiffness data from the four tests, (2) comparison of values of undrained shear strength and angle of internal friction developed from each of the test methods, (3) determination if pressuremeter data can be correlated to and thereby developed from one of the more rapid tests, (4) comparison of indirect soil type identifications from the standard borings, (5) development of information on the relative effort required for each test. Comparison of the penetration resistance stiffness data produced useful correlations among the CPT and DMT, with the SPT data yielding more erratic results. Shear strength data was most consistent for the marine clay sites, while the CPT and DMT returned useful friction angle data in the alluvial sands. PMT data correlated well to both the CPT and DMT test results. Correlation of PMT results to the SPT was more erratic. Indirect soil identification from the CPT and DMT was fully adequate for transmission line foundation design purposes, and finally, useful comparative data on the relative testing time required for the four in-situ tests was developed.« less
Influence of Piezosurgery on Bone Healing around Titanium Implants: A Histological Study in Rats.
Sirolli, Marcelo; Mafra, Carlos Eduardo Secco; Santos, Rodrigo Albuquerque Basílio Dos; Saraiva, Luciana; Holzhausen, Marinella; César, João Batista
2016-01-01
The aim of this study was to evaluate histomorphometrically the influence of two techniques of dental implant site preparation on bone healing around titanium implants. Fifteen male Wistar rats (±300 g) were used in the study. Each tibia was randomly assigned to receive the implant site preparation either with a conventional drilling technique (control - DRILL group) or with a piezoelectric device (PIEZO group). The animals were sacrificed after 30 days and then the following histomorphometric parameters were evaluated (percentage) separately for cortical and cancellous regions: proportion of mineralized tissue (PMT) adjacent to implant threads (500 μm adjacent); bone area within the threads (BA) and bone-implant contact (BIC). The results demonstrated that there were no statistically significant differences between both groups for cancellous BIC (p>0.05) and cortical PMT (p>0.05). On the other hand, a higher percentage of BA was observed in the PIEZO group in the cortical (71.50±6.91 and 78.28±4.38 for DRILL and PIEZO groups, respectively; p<0.05) and cancellous regions (9.62±4.06 and 19.94±14.18 for DRILL and PIEZO groups, respectively; p<0.05). The piezosurgery also showed higher PMT values in the cancellous zone (9.35±5.54 and 18.72±13.21 for DRILL and PIEZO groups, respectively; p<0.05). However, the DRILL group presented better results for BIC in cortical region (80.42±10.88 and 70.25±16.93 for DRILL and PIEZO groups, respectively; p<0.05). In conclusion, for the implant site preparation, the piezosurgery was beneficial to bone healing rates in the cancellous bone region, while the drill technique produced better results in the cortical bone.
NASA Astrophysics Data System (ADS)
Wong, Wai-Hoi; Li, Hongdi; Zhang, Yuxuan; Ramirez, Rocio; An, Shaohui; Wang, Chao; Liu, Shitao; Dong, Yun; Baghaei, Hossain
2015-10-01
We developed a high-resolution Photomultiplier-Quadrant-Sharing (PQS) PET system for human imaging. This system is made up of 24 detector panels. Each panel (bank) consists of 3 ×7 detector blocks, and each block has 16 ×16 LYSO crystals of 2.35 ×2.35 ×15.2 mm3. We used a novel detector-grinding scheme that is compatible with the PQS detector-pixel-decoding requirements to make a gapless cylindrical detector ring for maximizing detection efficiency while delivering an ultrahigh spatial-resolution for a whole-body PET camera with a ring diameter of 87 cm and axial field of view of 27.6 cm. This grinding scheme enables two adjacent gapless panels to share one row of the PMTs to extend the PQS configuration beyond one panel and thus maximize the economic benefit (in PMT usage) of the PQS design. The entire detector ring has 129,024 crystals, all of which are clearly decoded using only 576 PMTs (38-mm diameter). Thus, each PMT on average decodes 224 crystals to achieve a high crystal-pitch resolution of 2.44 mm ×2.44 mm. The detector blocks were mass-produced with our slab-sandwich-slice technique using a set of optimized mirror-film patterns (between crystals) to maximize light output and achieve high spatial and timing resolution. This detection system with time-of-flight capability was placed in a human PET/CT gantry. The reconstructed image resolution of the system was about 2.87 mm using 2D-filtered back-projection. The time-of-flight resolution was 473 ps. The preliminary images of phantoms and clinical studies presented in this work demonstrate the capability of this new PET/CT system to produce high-quality images.
Development of a Cost-Effective Modular Pixelated NaI(Tl) Detector for Clinical SPECT Applications
Rozler, Mike; Liang, Haoning; Chang, Wei
2013-01-01
A new pixelated detector for high-resolution clinical SPECT applications was designed and tested. The modular detector is based on a scintillator block comprised of 2.75×2.75×10 mm3 NaI(Tl) pixels and decoded by an array of 51 mm diameter single-anode PMTs. Several configurations, utilizing two types of PMTs, were evaluated using a collimated beam source to measure positioning accuracy directly. Good pixel separation was observed, with correct pixel identification ranging from 60 to 72% averaged over the entire area of the modules, depending on the PMT type and configuration. This translates to a significant improvement in positioning accuracy compared to continuous slab detectors of the same thickness, along with effective reduction of “dead” space at the edges. The observed 10% average energy resolution compares well to continuous slab detectors. The combined performance demonstrates the suitability of pixelated detectors decoded with a relatively small number of medium-sized PMTs as a cost-effective approach for high resolution clinical SPECT applications, in particular those involving curved detector geometries. PMID:24146436
On the Sensitivity of the HAWC Observatory to Gamma-Ray Bursts
NASA Technical Reports Server (NTRS)
Hays, E.; McEnery, Julie E.
2011-01-01
We present the sensitivity of HAWC to Gamma Ray Bursts (GRBs). HAWC is a very high-energy gamma-ray observatory currently under construction in Mexico at an altitude of 4100 m. It will observe atmospheric air showers via the water Cherenkov method. HAWC will consist of 300 large water tanks instrumented with 4 photomultipliers each. HAWC has two data acquisition (DAQ) systems. The main DAQ system reads out coincident signals in the tanks and reconstructs the direction and energy of individual atmospheric showers. The scaler DAQ counts the hits in each photomultiplier tube (PMT) in the detector and searches for a statistical excess over the noise of all PMTs. We show that HAWC has a realistic opportunity to observe the high-energy power law components of GRBs that extend at least up to 30 GeV, as it has been observed by Fermi LAT. The two DAQ systems have an energy threshold that is low enough to observe events similar to GRB 090510 and GRB 090902b with the characteristics observed by Fermi LAT. HAWC will provide information about the high-energy spectra of GRBs which in turn will lead to understanding about e-pair attenuation in GRB jets, extragalactic background light absorption, as well as establishing the highest energy to which GRBs accelerate particles.
NASA Astrophysics Data System (ADS)
Ifergan, Y.; Dadon, S.; Israelashvili, I.; Osovizky, A.; Gonen, E.; Yehuda-Zada, Y.; Smadja, D.; Knafo, Y.; Ginzburg, D.; Kadmon, Y.; Cohen, Y.; Mazor, T.
2015-06-01
Low level radioactive surface contamination measurements require lightweight, large area and high efficiency detector. In most existing scintillation detectors there is a tradeoff between effective area and scintillation light collection. By using wavelength shifting (WLS) fibers the scintillation light may be collected efficiently also in a large area detector. In this study, WLS fibers were coupled to a beta sensitive plastic scintillator layer and to a alpha sensitive silver-activated zinc sulfide ZnS(Ag) layer for detecting both alpha and beta particles. The WLS fibers collect the scintillation light from the whole detector and transfer it to a single PMT. This first prototype unique configuration enables monitoring radioactive contaminated surfaces by both sides of the detector and provides high gamma rejection. In this paper, the detector structure, as well as the detector's measured linear response, will be described. The measured detection efficiency of 238Pu alpha particles (5.5 MeV) is 63%. The measured detection efficiency for beta particles is 89% for 90Sr-90Y (average energy of 195.8 keV, 934.8 keV), 50% for 36Cl (average energy of 251.3 keV), and 35% for 137Cs (average energy of 156.8 keV).
Data Adjustments for TRACE-P, INTEX-A and INTEX-B
Atmospheric Science Data Center
2013-08-06
... that time, we have done repeated calibrations with two other methods: measuring the production of ozone from oxygen photolysis and the ... this notification. All of our four calibration methods indicate that the PMT calibration is incorrect, but they differ in the ...
Teaching Students How To Read Fear Appeals Critically.
ERIC Educational Resources Information Center
Lively, Malcolm
Fear appeals are persuasive messages that emphasize harmful physical or social consequences of failing to comply with message recommendations. Protection Motivation Theory (PMT) emphasizes cognitive or rational reactions to fear appeals and identifies four message components which initiate corresponding cognitive mediating processes of appraising…
Electromechanical response times in the knee muscles in young and old women.
Szpala, Agnieszka; Rutkowska-Kucharska, Alicja
2017-12-01
The aim of the study was to compare electromechanical response times [total reaction time (TRT), pre-motor time (PMT), and electromechanical delay] in the knee muscles in groups of young and older women during release of peak torque (PT). Fifty women (1 group approximately 20 years of age and the other approximately 60 years of age) participated in the study. PT and electromyographic activity were measured for flexors and extensors of the right and left knee in static conditions in response to a visual stimulus. Significantly longer TRTs (P = 0.05) and PMTs (P = 0.05) were found in the group of older women compared with the younger participants. Asymmetry was found between the older and the younger group of women in PT of knee flexors. Significantly longer TRT and PMT phases in the group of older women suggests a longer time for information processing in the central nervous system in older people. Muscle Nerve 56: E147-E153, 2017. © 2017 Wiley Periodicals, Inc.
Next generation gamma-ray Cherenkov detectors for the National Ignition Facility.
Herrmann, H W; Kim, Y H; McEvoy, A M; Zylstra, A B; Young, C S; Lopez, F E; Griego, J R; Fatherley, V E; Oertel, J A; Stoeffl, W; Khater, H; Hernandez, J E; Carpenter, A; Rubery, M S; Horsfield, C J; Gales, S; Leatherland, A; Hilsabeck, T; Kilkenny, J D; Malone, R M; Hares, J D; Milnes, J; Shmayda, W T; Stoeckl, C; Batha, S H
2016-11-01
The newest generation of Gas Cherenkov Detector (GCD-3) employed in Inertial Confinement Fusion experiments at the Omega Laser Facility has provided improved performance over previous generations. Comparison of reaction histories measured using two different deuterium-tritium fusion products, namely gamma rays using GCD and neutrons using Neutron Temporal Diagnostic (NTD), have provided added credibility to both techniques. GCD-3 is now being brought to the National Ignition Facility (NIF) to supplement the existing Gamma Reaction History (GRH-6m) located 6 m from target chamber center (TCC). Initially it will be located in a reentrant well located 3.9 m from TCC. Data from GCD-3 will inform the design of a heavily-shielded "Super" GCD to be located as close as 20 cm from TCC. It will also provide a test-bed for faster optical detectors, potentially lowering the temporal resolution from the current ∼100 ps state-of-the-art photomultiplier tubes (PMT) to ∼10 ps Pulse Dilation PMT technology currently under development.
Performance of the MCP-PMT for the Belle II TOP counter in a magnetic field
NASA Astrophysics Data System (ADS)
Hirose, S.
2014-12-01
The time of propagation (TOP) counter is a novel particle identification device for the Belle II experiment, utilizing the ring imaging Cherenkov technique. It is composed of a 2.7 m long quartz bar and 32 micro channel plate photomultiplier tubes (MCP-PMTs) attached on the end of the bar. The MCP-PMT has a typical quantum efficiency of 28%, a photoelectron collection efficiency of about 55%, and a transit time spread (TTS) less than 50 ps for single photon detection. Since the TOP counters are installed in the 1.5 T magnetic field of the Belle II detector, the MCP-PMTs are required to keep those characteristics with gain of more than 5×105 in the magnetic field. Therefore, we investigated gain, TTS, and single photon detection efficiency of the MCP-PMTs in the magnetic field and found that they satisfy the requirements. We are starting complete inspections for more than 500 MCP-PMTs, and have inspected up to 87 MCP-PMTs.
KM3NeT Digital Optical Module electronics
NASA Astrophysics Data System (ADS)
Real, Diego
2016-04-01
The KM3NeT collaboration is currently building of a neutrino telescope with a volume of several cubic kilometres at the bottom of the Mediterranean Sea. The telescope consists of a matrix of Digital Optical Modules that will detect the Cherenkov light originated by the interaction of the neutrinos in the proximity of the detector. This contribution describes the main components of the read-out electronics of the Digital Optical Module: the Power Board, which delivers all the power supply required by the Digital Optical Molule electronics; the Central Logic Board, the main core of the read-out system, hosting 31 Time to Digital Converters with 1 ns resolution and the White Rabbit protocol embedded in the Central Logic Board Field Programmable Gate Array; the Octopus boards, that transfer the Low Voltage Digital Signals from the PMT bases to the Central Logic Board and finally the PMT bases, in charge of converting the analogue signal produced in the 31 3" PMTs into a Low Voltage Digital Signal.
A time-domain fluorescence diffusion optical tomography system for breast tumor diagnosis
NASA Astrophysics Data System (ADS)
Zhang, Wei; Gao, Feng; Wu, LinHui; Ma, Wenjuan; Yang, Fang; Zhou, Zhongxing; Zhang, Limin; Zhao, Huijuan
2011-02-01
A prototype time-domain fluorescence diffusion optical tomography (FDOT) system using near-infrared light is presented. The system employs two pulsed light sources, 32 source fibers and 32 detection channels, working separately for acquiring the temporal distribution of the photon flux on the tissue surface. The light sources are provided by low power picosecond pulsed diode lasers at wavelengths of 780 nm and 830 nm, and a 1×32-fiber-optic-switch sequentially directs light sources to the object surface through 32 source fibers. The light signals re-emitted from the object are collected by 32 detection fibers connected to four 8×1 fiber-optic-switch and then routed to four time-resolved measuring channels, each of which consists of a collimator, a filter wheel, a photomultiplier tube (PMT) photon-counting head and a time-correlated single photon counting (TCSPC) channel. The performance and efficacy of the designed multi-channel PMT-TCSPC system are assessed by reconstructing the fluorescent yield and lifetime images of a solid phantom.
Ashida, Sato; Heaney, Catherine A; Kmet, Jennifer M; Wilkins, J R
2011-05-01
The North American Guidelines for Children's Agricultural Tasks (NAGCAT) were developed to reduce childhood agricultural injuries by assisting adults in assigning appropriate chores and providing needed supervision and training. To develop an effective intervention to increase adherence to NAGCAT among farm parents, formative research (focus groups and pilot-testing) was conducted. Protection motivation theory (PMT) was used to guide this research and inform intervention development. Focus group results suggested how PMT constructs might be addressed to increase adherence. A home visit intervention, using a standardized presentation in POWERPoint™, was developed to (a) introduce NAGCAT, (b) increase motivation to use NAGCAT and enhance safe work behaviors, and (c) ultimately reduce agricultural work-related injuries among youth. Process evaluation data suggests that the intervention was well received by farm parents. Conducting theory-guided formative research identified motivational barriers and strategies for overcoming these barriers that might not have been otherwise apparent.
Huo, Ming; Wang, Hongzhao; Ge, Meng; Huang, Qiuchen; Li, Desheng; Maruyama, Hitoshi
2013-11-01
[Purpose] The aim of this study was to investigate the change in electromechanical reaction times (EMG-RT) of hip flexion of younger persons after neuromuscular joint facilitation (NJF) treatment. [Subjects] The subjects were 39 healthy young people, who were divided into two groups: a NJF group and a proprioceptive neuromuscular facilitation (PNF) group. The NJF group consisted of 16 subjects (7 males, 9 females), and the PNF group consisted of 23 subjects (10 males, 13 females). [Methods] Participants in the NJF group received NJF treatment. We measured the EMG-RT, the premotor time (PMT) and the motor time (MT) during hip flexion movement before and after the intervention in both groups. [Results] There were no significant differences among the results of the PNF group. For the NJF group, there were significant differences in PMT and EMG-RT after NJF treatment. [Conclusion] These results suggest that there is an immediate effect of NJF intervention on electromechanical reaction times of hip flexion.
Huo, Ming; Wang, Hongzhao; Ge, Meng; Huang, Qiuchen; Li, Desheng; Maruyama, Hitoshi
2013-01-01
[Purpose] The aim of this study was to investigate the change in electromechanical reaction times (EMG-RT) of hip flexion of younger persons after neuromuscular joint facilitation (NJF) treatment. [Subjects] The subjects were 39 healthy young people, who were divided into two groups: a NJF group and a proprioceptive neuromuscular facilitation (PNF) group. The NJF group consisted of 16 subjects (7 males, 9 females), and the PNF group consisted of 23 subjects (10 males, 13 females). [Methods] Participants in the NJF group received NJF treatment. We measured the EMG-RT, the premotor time (PMT) and the motor time (MT) during hip flexion movement before and after the intervention in both groups. [Results] There were no significant differences among the results of the PNF group. For the NJF group, there were significant differences in PMT and EMG-RT after NJF treatment. [Conclusion] These results suggest that there is an immediate effect of NJF intervention on electromechanical reaction times of hip flexion. PMID:24396211
Combined readout of a triple-GEM detector
NASA Astrophysics Data System (ADS)
Antochi, V. C.; Baracchini, E.; Cavoto, G.; Di Marco, E.; Marafini, M.; Mazzitelli, G.; Pinci, D.; Renga, F.; Tomassini, S.; Voena, C.
2018-05-01
Optical readout of GEM based devices by means of high granularity and low noise CMOS sensors allows to obtain very interesting tracking performance. Space resolution of the order of tens of μm were measured on the GEM plane along with an energy resolution of 20%÷30%. The main limitation of CMOS sensors is represented by their poor information about time structure of the event. In this paper, the use of a concurrent light readout by means of a suitable photomultiplier and the acquisition of the electric signal induced on the GEM electrode are exploited to provide the necessary timing informations. The analysis of the PMT waveform allows a 3D reconstruction of each single clusters with a resolution on z of 100 μm. Moreover, from the PMT signals it is possible to obtain a fast reconstruction of the energy released within the detector with a resolution of the order of 25% even in the tens of keV range useful, for example, for triggering purpose.
We can cure your child's clumsiness! A review of intervention methods.
Sigmundsson, H; Pedersen, A V; Whiting, H T; Ingvaldsen, R P
1998-06-01
Intervention procedures for treatment of clumsiness have come in many guises. We have looked at some of the most powerful methods put forward in the past 30 years--Perceptual-motor training (PMT), Sensory Integration Therapy (SIT), and some promising new approaches. Both the PMT and the SIT have been heavily criticised. It is hard to find support for the idea that the programmes improve academic skills or that they have more than a limited effect on perceptual-motor development as claimed. The more recently introduced Kinaesthetic training is shown to have an effect on general motor competence but that this may be better explained in terms of the general principles on which this training procedure lies rather than the influence on Kinaesthesis per se. Since other recent studies have also shown a dependence on similar general principles, it might be asked whether it is the teacher rather than the programmes that accounts for the differences shown between different intervention programmes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agnes, P.; Albuquerque, I. F. M.; Alexander, T.
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics include resistive voltage dividers on the PMTs,more » custom pre-amplifiers mounted directly on the PMT voltage dividers in the liquid argon, and custom amplifier/discriminators (at room temperature). After amplification, the PMT signals are digitized in CAEN waveform digitizers, and CAEN logic modules are used to construct the trigger, the data acquisition system for the TPC is based on the Fermilab "artdaq" software. The system has been in operation since early 2014.« less
NASA Technical Reports Server (NTRS)
Niciejewski, Rick; Killeen, Timothy L.; Turnbull, Matthew
1994-01-01
The application of Fabry-Perot interferometers (FPIs) to the study of upper atmosphere thermodynamics has largely been restricted by the very low light levels in the terrestrial airglow as well as the limited range in wavelength of photomultiplier tube (PMT) technology. During the past decade, the development of the scientific grade charge-coupled device (CCD) has progressed to the stage in which this detector has become the logical replacement for the PMT. Small fast microcomputers have made it possible to "upgrade" our remote field sites with bare CCDs and not only retain the previous capabilities of the existing FPls but expand the data coverage in both temporal and wavelength domains. The problems encountered and the solutions applied to the deployment of a bare CCD, with data acquisition and image reduction techniques, are discussed. Sample geophysical data determined from the FPI fringe profiles are shown for our stations at Peach Mountain, Michigan, and Watson Lake, Yukon Territory.
Characterization of the Hamamatsu 8" R5912-MOD Photomultiplier tube
NASA Astrophysics Data System (ADS)
Kaptanoglu, Tanner
2018-05-01
Current and future neutrino and direct detection dark matter experiments hope to take advantage of improving technologies in photon detection. Many of these detectors are large, monolithic optical detectors that use relatively low-cost, large-area, and efficient photomultiplier tubes (PMTs). A candidate PMT for future experiments is a newly developed prototype Hamamatsu PMT, the R5912-MOD. In this paper we describe measurements made of the single photoelectron time and charge response of the R5912-MOD, as well as detail some direct comparisons to similar PMTs. Most of these measurements were performed on three R5912-MOD PMTs operating at gains close to 1 × 107. The transit time spread (σ) and the charge peak-to-valley were measured to be on average 680ps and 4.2 respectively. The results of this paper show the R5912-MOD is an excellent candidate for future experiments in several regards, particularly due to its narrow spread in timing.
The NASA Program Management Tool: A New Vision in Business Intelligence
NASA Technical Reports Server (NTRS)
Maluf, David A.; Swanson, Keith; Putz, Peter; Bell, David G.; Gawdiak, Yuri
2006-01-01
This paper describes a novel approach to business intelligence and program management for large technology enterprises like the U.S. National Aeronautics and Space Administration (NASA). Two key distinctions of the approach are that 1) standard business documents are the user interface, and 2) a "schema-less" XML database enables flexible integration of technology information for use by both humans and machines in a highly dynamic environment. The implementation utilizes patent-pending NASA software called the NASA Program Management Tool (PMT) and its underlying "schema-less" XML database called Netmark. Initial benefits of PMT include elimination of discrepancies between business documents that use the same information and "paperwork reduction" for program and project management in the form of reducing the effort required to understand standard reporting requirements and to comply with those reporting requirements. We project that the underlying approach to business intelligence will enable significant benefits in the timeliness, integrity and depth of business information available to decision makers on all organizational levels.
47 CFR 76.1909 - Redistribution control of unencrypted digital terrestrial broadcast content.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 4 2010-10-01 2010-10-01 false Redistribution control of unencrypted digital... Redistribution control of unencrypted digital terrestrial broadcast content. (a) For the purposes of this section, the terms unencrypted digital terrestrial broadcast content, EIT, PMT, broadcast flag, covered...
The laser calibration system of the TOP detector
NASA Astrophysics Data System (ADS)
Tamponi, Umberto
2017-12-01
The TOP detector of the Belle II Experiment at KEK is a particle identification detector, devoted mainly to the separation of charged pions and kaons. The Cherenkov photons produced in fused silica bars are detected by an array of micro-cannel plate photomultipliers, and the position and time of arrival of the photoelectrons are used to identify the particle. In order to achieve a time resolution of less than 100 ps, the performance of electronics and PMTs must be continuously monitored by a high resolution laser calibration system. Here we report about the design, characterization, construction and installation of this light distribution system consisting of a picosecond laser source, a printed light circuit (PLC), long single mode fibers coupled to bundles of multimode fibers terminated with graded index microlenses, to provide illumination of all the PMT pixels with time jitter less than 50 ps.
Systematic Changes in Families Following Prevention Trials
ERIC Educational Resources Information Center
Patterson, Gerald R.; DeGarmo, David; Forgatch, Marion S.
2004-01-01
A selective prevention design was applied to 238 recently separated families. Of these, 153 mothers randomly assigned to the experimental (E) group participated in 14 group sessions focused on Parent Management Treatment (PMT). Prior analyses showed that, over time, the group of families in the untreated group deteriorated in both parenting…
Position reconstruction in LUX
Akerib, D. S.; Alsum, S.; Araújo, H. M.; ...
2018-02-01
The (x, y) position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional form to account for the photons reflected on the inner walls of the detector. To increase the resolution for small pulses, a photon counting technique was employed to describe the response of the PMTs. The reconstruction was assessedmore » with calibration data including 83mKr (releasing a total energy of 41.5 keV) and 3H (β - with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron beam (2.45 MeV). Within the detector's fiducial volume, the reconstruction has achieved an (x, y) position uncertainty of σ = 0.82 cm and σ = 0.17 cm for events of only 200 and 4,000 detected electroluminescence photons respectively. Such signals are associated with electron recoils of energies ~0.25 keV and ~10 keV, respectively. Lastly, the reconstructed position of the smallest events with a single electron emitted from the liquid surface (22 detected photons) has a horizontal (x, y) uncertainty of 2.13 cm.« less
Position reconstruction in LUX
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akerib, D. S.; Alsum, S.; Araújo, H. M.
The (x, y) position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional form to account for the photons reflected on the inner walls of the detector. To increase the resolution for small pulses, a photon counting technique was employed to describe the response of the PMTs. The reconstruction was assessedmore » with calibration data including 83mKr (releasing a total energy of 41.5 keV) and 3H (β - with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron beam (2.45 MeV). Within the detector's fiducial volume, the reconstruction has achieved an (x, y) position uncertainty of σ = 0.82 cm and σ = 0.17 cm for events of only 200 and 4,000 detected electroluminescence photons respectively. Such signals are associated with electron recoils of energies ~0.25 keV and ~10 keV, respectively. Lastly, the reconstructed position of the smallest events with a single electron emitted from the liquid surface (22 detected photons) has a horizontal (x, y) uncertainty of 2.13 cm.« less
Position reconstruction in LUX
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akerib, D. S.; Alsum, S.; Araújo, H. M.
© 2018 IOP Publishing Ltd and Sissa Medialab. The (x, y) position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional form to account for the photons reflected on the inner walls of the detector. To increase the resolution for small pulses, a photon counting technique was employed to describe themore » response of the PMTs. The reconstruction was assessed with calibration data including 83m Kr (releasing a total energy of 41.5 keV) and 3 H (andbeta; - with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron beam (2.45 MeV) . Within the detector's fiducial volume, the reconstruction has achieved an (x, y) position uncertainty of andsigma; = 0.82 cm and andsigma; = 0.17 cm for events of only 200 and 4,000 detected electroluminescence photons respectively. Such signals are associated with electron recoils of energies andsim;0.25 keV and andsim;10 keV, respectively. The reconstructed position of the smallest events with a single electron emitted from the liquid surface (22 detected photons) has a horizontal (x, y) uncertainty of 2.13 cm.« less
Position reconstruction in LUX
Akerib, D. S.; Alsum, S.; Araújo, H. M.; ...
2018-02-01
© 2018 IOP Publishing Ltd and Sissa Medialab. The (x, y) position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional form to account for the photons reflected on the inner walls of the detector. To increase the resolution for small pulses, a photon counting technique was employed to describe themore » response of the PMTs. The reconstruction was assessed with calibration data including 83m Kr (releasing a total energy of 41.5 keV) and 3 H (andbeta; - with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron beam (2.45 MeV) . Within the detector's fiducial volume, the reconstruction has achieved an (x, y) position uncertainty of andsigma; = 0.82 cm and andsigma; = 0.17 cm for events of only 200 and 4,000 detected electroluminescence photons respectively. Such signals are associated with electron recoils of energies andsim;0.25 keV and andsim;10 keV, respectively. The reconstructed position of the smallest events with a single electron emitted from the liquid surface (22 detected photons) has a horizontal (x, y) uncertainty of 2.13 cm.« less
Application of artificial neural network in 3D imaging with lanthanum bromide calorimeter
NASA Astrophysics Data System (ADS)
Gostojic, A.; Tatischeff, V.; Kiener, J.; Hamadache, C.; Karkour, N.; Linget, D.; Grave, X.; Gibelin, L.; Travers, B.; Blin, S.; Barrillon, P.
2015-07-01
Gamma-ray astronomy in the energy range from 0.1 up to 100 MeV holds many understudied questions connected with e.g. stellar nucleosynthesis, the active Sun, neutron stars and black holes. To access the physics behind, a significant improvement in detection sensitivity is needed compared to previous missions, e.g. CGRO and INTEGRAL. One of the promising concepts for a future gamma-ray mission is an Advanced Compton Telescope. Under the project of creating a prototype of such instrument, we study the perspectives of using a novel inorganic scintillator as a calorimeter part. Modern inorganic crystal or ceramics scintillators are constantly improving on qualities such as energy resolution and radiation hardness, and this makes them a smart choice for a new space-borne telescope. At CSNSM Orsay, we have assembled a detection module from a 5 × 5cm2 area and 1 cm thick, cerium-doped lanthanum (III) bromide (LaBr3:Ce) inorganic scintillator coupled to a 64 channel multi-anode photomultiplier. The readout of the PMT signals is carried out with the ASIC MAROC, used previously for the luminometer of the ATLAS detector (CERN). Characterization, thorough measurements with various radioactive sources, as well as, single photoelectron detection have been done. Furthermore, we made a comparison of measurements with a detailed GEANT4-based simulation which includes tracking of the optical photons. Finally, we have studied the 3D reconstruction of the first interaction point of incident gamma rays, utilizing a neural network algorithm. This spatial position resolution plays a crucial part in the future implementations and, together with the other measured properties, it makes our detector module very interesting for the next generation of space telescopes operating in the MeV range.
Use of annual phosphorus loss estimator (APLE) model to evaluate a phosphorus index
USDA-ARS?s Scientific Manuscript database
Maryland’s Phosphorus Site Index (MD-PSI) has been used to guide management decisions to minimize the potential for phosphorus (P) loss from agricultural fields in Maryland since 2002. The index was recently revised and renamed the University of Maryland Phosphorus Management Tool (UM-PMT), and the...
Case Study: Parent-Implemented Prelinguistic Milieu Teaching with a High Risk Dyad
ERIC Educational Resources Information Center
McCathren, Rebecca B.
2010-01-01
The purpose of this study was twofold. The first purpose was to determine if a mother with mild developmental disabilities living in poverty was able to implement Prelinguistic Milieu Teaching (PMT) strategies. The strategies included following the child's lead, arranging the environment to increase opportunities for communication, imitating the…
Brucella abortus Synthesizes Phosphatidylcholine from Choline Provided by the Host
Comerci, Diego J.; Altabe, Silvia; de Mendoza, Diego; Ugalde, Rodolfo A.
2006-01-01
The Brucella cell envelope is characterized by the presence of phosphatidylcholine (PC), a common phospholipid in eukaryotes that is rare in prokaryotes. Studies on the composition of Brucella abortus 2308 phospholipids revealed that the synthesis of PC depends on the presence of choline in the culture medium, suggesting that the methylation biosynthetic pathway is not functional. Phospholipid composition of pmtA and pcs mutants indicated that in Brucella, PC synthesis occurs exclusively via the phosphatidylcholine synthase pathway. Transformation of Escherichia coli with an expression vector containing the B. abortus pcs homologue was sufficient for PC synthesis upon induction with IPTG (isopropyl-β-d-thiogalactopyranoside), while no PC formation was detected when bacteria were transformed with a vector containing pmtA. These findings imply that Brucella depends on choline provided by the host cell to form PC. We could not detect any obvious associated phenotype in the PC-deficient strain under vegetative or intracellular growth conditions in macrophages. However, the pcs mutant strain displays a reproducible virulence defect in mice, which suggests that PC is necessary to sustain a chronic infection process. PMID:16484204
Next Generation Gamma-Ray Cherenkov Detectors for the National Ignition Facility
Herrmann, Hans W.; Kim, Yong Ho; McEvoy, Aaron Matthew; ...
2016-10-19
The newest generation of Gas Cherenkov Detector (GCD-3) employed in Inertial Confinement Fusion experiments at the Omega Laser Facility has provided improved performance over previous generations. Comparison of reaction histories measured using two different deuterium-tritium fusion products, namely gamma rays using GCD and neutrons using Neutron Temporal Diagnostic (NTD), have provided added credibility to both techniques. GCD-3 is now being brought to the National Ignition Facility (NIF) to supplement the existing Gamma Reaction History (GRH-6m) located 6 m from target chamber center (TCC). Initially it will be located in a reentrant well located 3.9 m from TCC. Data from GCD-3more » will inform the design of a heavily-shielded “Super” GCD to be located as close as 20 cm from TCC. In conclusion, it will also provide a test-bed for faster optical detectors, potentially lowering the temporal resolution from the current ~100 ps state-of-the-art photomultiplier tubes (PMT) to ~10 ps Pulse Dilation PMT technology currently under development.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agnes, P.; Albuquerque, I. F. M.; Alexander, T.
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics include resistive voltage dividers on the PMTs,more » custom pre-amplifiers mounted directly on the PMT voltage dividers in the liquid argon, and custom amplifier/discriminators (at room temperature). After amplification, the PMT signals are digitized in CAEN waveform digitizers, and CAEN logic modules are used to construct the trigger, the data acquisition system for the TPC is based on the Fermilab "artdaq" software. The system has been in operation since early 2014.« less
Ma, Xingyi; Sim, Sang Jun
2013-03-21
Even though DNA-based nanosensors have been demonstrated for quantitative detection of analytes and diseases, hybridization events have never been numerically investigated for further understanding of DNA mediated interactions. Here, we developed a nanoscale platform with well-designed capture and detection gold nanoprobes to precisely evaluate the hybridization events. The capture gold nanoprobes were mono-laid on glass and the detection probes were fabricated via a novel competitive conjugation method. The two kinds of probes combined in a suitable orientation following the hybridization with the target. We found that hybridization efficiency was markedly dependent on electrostatic interactions between DNA strands, which can be tailored by adjusting the salt concentration of the incubation solution. Due to the much lower stability of the double helix formed by mismatches, the hybridization efficiencies of single mismatched (MMT) and perfectly matched DNA (PMT) were different. Therefore, we obtained an optimized salt concentration that allowed for discrimination of MMT from PMT without stringent control of temperature or pH. The results indicated this to be an ultrasensitive and precise nanosensor for the diagnosis of genetic diseases.
Judged effectiveness of threat and coping appraisal anti-speeding messages.
Cathcart, Rachel L; Glendon, A Ian
2016-11-01
Using a young driver sample, this experimental study sought to identify which combinations of threat-appraisal (TA) and coping-appraisal (CA) messages derived from protection motivation theory (PMT) participants would judge as most effective for themselves, and for other drivers. The criterion variable was reported intention to drive within a signed speed limit. All possible TA/CA combinations of 18 previously highly-rated anti-speeding messages were presented both simultaneously and sequentially. These represented PMT's three TA components: severity, vulnerability, and rewards, and three CA components: self-efficacy, response efficacy, and response costs. Eighty-eight young drivers (34 males) each rated 54 messages for perceived effectiveness for self and other drivers. Messages derived from the TA severity component were judged the most effective. Response cost messages were most effective for females. Reverse third-person effects were found for both females and males, which suggested that combining TA and CA components may increase the perceived relevance of anti-speeding messages for males. The findings have potential value for creating effective roadside anti-speeding messages, meriting further investigation in field studies. Copyright © 2016 Elsevier Ltd. All rights reserved.
Longitudinal uniformity, time performances and irradiation test of pure CsI crystals
NASA Astrophysics Data System (ADS)
Angelucci, M.; Atanova, O.; Baccaro, S.; Cemmi, A.; Cordelli, M.; Donghia, R.; Giovannella, S.; Happacher, F.; Miscetti, S.; Sarra, I.; Soleti, S. R.
2016-07-01
To study an alternative to BaF2, as the crystal choice for the Mu2e calorimeter, 13 pure CsI crystals from Opto Materials and ISMA producers have been characterized by determining their light yield (LY) and longitudinal response uniformity (LRU), when read with a UV extended PMT. The crystals show a LY of 100 p.e./MeV ( 150 p.e./MeV) when wrapped with Tyvek and coupled to the PMT without (with) optical grease. The LRU is well represented by a linear slope that is on average δ -0.6%/cm. The timing performances of the Opto Materials crystal, read with a UV extended MPPC, have been evaluated with minimum ionizing particles. A timing resolution of 330 ps ( 440 ps) is achieved when connecting the photosensor to the MPPC with (without) optical grease. The crystal radiation hardness to a ionization dose has also been studied for one pure CsI crystal from SICCAS. After exposing it to a dose of 900 Gy, a decrease of 33% in the LY is observed while the LRU remains unchanged.
A novel ZVS high voltage power supply for micro-channel plate photomultiplier tubes
NASA Astrophysics Data System (ADS)
Pei, Chengquan; Tian, Jinshou; Liu, Zhen; Qin, Hong; Wu, Shengli
2017-04-01
A novel resonant high voltage power supply (HVPS) with zero voltage switching (ZVS), to reduce the voltage stress on switching devices and improve conversion efficiency, is proposed. The proposed HVPS includes a drive circuit, a transformer, several voltage multiplying circuits, and a regulator circuit. The HVPS contains several secondary windings that can be precisely regulated. The proposed HVPS performed better than the traditional resistor voltage divider, which requires replacing matching resistors resulting in resistor dispersibility in the Micro-Channel Plate (MCP). The equivalent circuit of the proposed HVPS was established and the operational principle analyzed. The entire switching element can achieve ZVS, which was validated by a simulation and experiments. The properties of this HVPS were tested including minimum power loss (240 mW), maximum power loss (1 W) and conversion efficiency (85%). The results of this research are that the proposed HVPS was suitable for driving the micro-channel plate photomultiplier tube (MCP-PMT). It was therefore adopted to test the MCP-PMT, which will be used in Daya Bay reactor neutrino experiment II in China.
NASA Astrophysics Data System (ADS)
Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Arisaka, K.; Asner, D. M.; Ave, M.; Back, H. O.; Baldin, B.; Biery, K.; Bocci, V.; Bonfini, G.; Bonivento, W.; Bossa, M.; Bottino, B.; Brigatti, A.; Brodsky, J.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadoni, M.; Calaprice, F.; Canci, N.; Candela, A.; Cao, H.; Caravati, M.; Cariello, M.; Carlini, M.; Catalanotti, S.; Cataudella, V.; Cavalcante, P.; Chepurnov, A.; Cicaló, C.; Cocco, A. G.; Covone, G.; Crippa, L.; D'Angelo, D.; D'Incecco, M.; Davini, S.; de Candia, A.; De Cecco, S.; De Deo, M.; De Filippis, G.; De Rosa, G.; De Vincenzi, M.; Derbin, A.; Devoto, A.; Di Eusanio, F.; Dionisi, C.; Di Pietro, G.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Forster, G.; Franco, D.; Gabriele, F.; Galbiati, C.; Giagu, S.; Giganti, C.; Giovanetti, G. K.; Goretti, A. M.; Granato, F.; Grandi, L.; Gromov, M.; Guan, M.; Guardincerri, Y.; Hackett, B. R.; Herner, K. R.; Hughes, D.; Humble, P.; Hungerford, E. V.; Ianni, A.; Ianni, A.; James, I.; Johnson, T. N.; Keeter, K.; Kendziora, C. L.; Kobychev, V.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Li, X.; Lissia, M.; Loer, B.; Lombardi, P.; Longo, G.; Luitz, S.; Ma, Y.; Machado, A.; Machulin, I. N.; Mandarano, A.; Mari, S. M.; Maricic, J.; Marini, L.; Martoff, C. J.; Meyers, P. D.; Miletic, T.; Milincic, R.; Montanari, D.; Monte, A.; Montuschi, M.; Monzani, M. E.; Mosteiro, P.; Mount, B. J.; Muratova, V. N.; Musico, P.; Navrer Agasson, A.; Nelson, A.; Odrowski, S.; Oleinik, A.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pantic, E.; Parmeggiano, S.; Pelczar, K.; Pelliccia, N.; Pocar, A.; Pordes, S.; Pugachev, D. A.; Qian, H.; Randle, K.; Ranucci, G.; Razeti, M.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Rescigno, M.; Riffard, Q.; Romani, A.; Rossi, B.; Rossi, N.; Rountree, S. D.; Sablone, D.; Saggese, P.; Saldanha, R.; Sands, W.; Sangiorgio, S.; Savarese, C.; Schlitzer, B.; Segreto, E.; Semenov, D. A.; Shields, E.; Singh, P. N.; Skorokhvatov, M. D.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Suvorov, Y.; Tartaglia, R.; Tatarowicz, J.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Verducci, M.; Vishneva, A.; Vogelaar, R. B.; Wada, M.; Walker, S.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wojcik, M. M.; Xiang, X.; Xiao, X.; Xu, J.; Yang, C.; Yoo, J.; Zavatarelli, S.; Zec, A.; Zhong, W.; Zhu, C.; Zuzel, G.
2017-12-01
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics include resistive voltage dividers on the PMTs, custom pre-amplifiers mounted directly on the PMT voltage dividers in the liquid argon, and custom amplifier/discriminators (at room temperature). After amplification, the PMT signals are digitized in CAEN waveform digitizers, and CAEN logic modules are used to construct the trigger; the data acquisition system for the TPC is based on the Fermilab artdaq software. The system has been in operation since early 2014.
NASA Astrophysics Data System (ADS)
Cervantes, Omar; Reyes, Liliana; Hooks, Tyler; Perez, Luis; Ritt, Stefan
2016-03-01
To construct a cosmic detector array using 4 scintillation detectors, we investigated 2 recent light sensor technologies from Hamamatsu, as possible readout detectors. First, we investigated several homemade versions of the multipixel photon counter (MPPC) light sensors. These detectors were either biased with internal or external high voltage power supplies. We made extensive measurements to confirm for the coincidence of the MPPC devices. Each sensor is coupled to a wavelength shifting fiber (WSF) that is embedded along a plastic scintillator sheet (30cmx60cmx1/4''). Using energetic cosmic rays, we evaluated several of these homemade detector modules placed above one another in a light proof enclosure. Next, we assembled 2 miniaturized micro photomultiplier (micro PMT), a device recently marketed by Hamamatsu. These sensors showed very fast response times. With 3 WSF embedded in scintillator sheets, we performed coincidence experiments. The detector waveforms were captured using the 5GS/sec domino ring sampler, the DRS4 and our workflow using the CERN PAW package and data analysis results would be presented. Title V Grant.
Scintillation properties of Tm-doped Lu 3Al 5O 12 single crystals
NASA Astrophysics Data System (ADS)
Sugiyama, Makoto; Fujimoto, Yutaka; Yanagida, Takayuki; Totsuka, Daisuke; Yokota, Yuui; Yoshikawa, Akira
2011-12-01
Using the micro-pulling-down (μ-PD) method, Tm-doped Lu 3Al 5O 12 (Tm:LuAG) single crystals were grown to examine their scintillation properties. In transmittance spectra, they exhibited about 80% transparency in the wavelengths longer than 320 nm and five absorption lines due to Tm 3+ 4f-4f transitions were observed. 241Am α-ray excited radioluminescence spectra were measured and intense 4f-4f emission peaks were observed with the host emission. When excited by 137Cs γ-Ray to obtain pulse height spectra, Tm 1% doped LuAG showed the highest light yield coupled with a photomultiplier (PMT) or a silicon avalanche photodiode (Si-APD). The light yield was estimated to be 5800 and 7300 photons/MeV for PMT and Si-APD, respectively. Decay time profiles consist of two exponential components and the fast and slow components are considered to be attributed to the host and the combination of the host and Tm 3+ 4f-4f emission, respectively.
The electronics system for the LBNL positron emission mammography (PEM) camera
NASA Astrophysics Data System (ADS)
Moses, W. W.; Young, J. W.; Baker, K.; Jones, W.; Lenox, M.; Ho, M. H.; Weng, M.
2001-06-01
Describes the electronics for a high-performance positron emission mammography (PEM) camera. It is based on the electronics for a human brain positron emission tomography (PET) camera (the Siemens/CTI HRRT), modified to use a detector module that incorporates a photodiode (PD) array. An application-specified integrated circuit (ASIC) services the photodetector (PD) array, amplifying its signal and identifying the crystal of interaction. Another ASIC services the photomultiplier tube (PMT), measuring its output and providing a timing signal. Field-programmable gate arrays (FPGAs) and lookup RAMs are used to apply crystal-by-crystal correction factors and measure the energy deposit and the interaction depth (based on the PD/PMT ratio). Additional FPGAs provide event multiplexing, derandomization, coincidence detection, and real-time rebinning. Embedded PC/104 microprocessors provide communication, real-time control, and configure the system. Extensive use of FPGAs make the overall design extremely flexible, allowing many different functions (or design modifications) to be realized without hardware changes. Incorporation of extensive onboard diagnostics, implemented in the FPGAs, is required by the very high level of integration and density achieved by this system.
NASA Technical Reports Server (NTRS)
Singh, Jagdish P.; Yueh, Fang-Yu; Kalluru, Rajamohan R.; Harrison, Louie
2012-01-01
An integrated fiber-optic Raman sensor has been designed for real-time, nonintrusive detection of liquid nitrogen in liquid oxygen (LOX) at high pressures and high flow rates in order to monitor the quality of LOX used during rocket engine ground testing. The integrated sensor employs a high-power (3-W) Melles Griot diode-pumped, solid-state (DPSS), frequency-doubled Nd:YAG 532- nm laser; a modified Raman probe that has built-in Raman signal filter optics; two high-resolution spectrometers; and photomultiplier tubes (PMTs) with selected bandpass filters to collect both N2 and O2 Raman signals. The PMT detection units are interfaced with National Instruments Lab- VIEW for fast data acquisition. Studies of sensor performance with different detection systems (i.e., spectrometer and PMT) were carried out. The concentration ratio of N2 and O2 can be inferred by comparing the intensities of the N2 and O2 Raman signals. The final system was fabricated to measure N2 and O2 gas mixtures as well as mixtures of liquid N2 and LOX
NASA Astrophysics Data System (ADS)
Akashi-Ronquest, M.; Amaudruz, P.-A.; Batygov, M.; Beltran, B.; Bodmer, M.; Boulay, M. G.; Broerman, B.; Buck, B.; Butcher, A.; Cai, B.; Caldwell, T.; Chen, M.; Chen, Y.; Cleveland, B.; Coakley, K.; Dering, K.; Duncan, F. A.; Formaggio, J. A.; Gagnon, R.; Gastler, D.; Giuliani, F.; Gold, M.; Golovko, V. V.; Gorel, P.; Graham, K.; Grace, E.; Guerrero, N.; Guiseppe, V.; Hallin, A. L.; Harvey, P.; Hearns, C.; Henning, R.; Hime, A.; Hofgartner, J.; Jaditz, S.; Jillings, C. J.; Kachulis, C.; Kearns, E.; Kelsey, J.; Klein, J. R.; Kuźniak, M.; LaTorre, A.; Lawson, I.; Li, O.; Lidgard, J. J.; Liimatainen, P.; Linden, S.; McFarlane, K.; McKinsey, D. N.; MacMullin, S.; Mastbaum, A.; Mathew, R.; McDonald, A. B.; Mei, D.-M.; Monroe, J.; Muir, A.; Nantais, C.; Nicolics, K.; Nikkel, J. A.; Noble, T.; O'Dwyer, E.; Olsen, K.; Orebi Gann, G. D.; Ouellet, C.; Palladino, K.; Pasuthip, P.; Perumpilly, G.; Pollmann, T.; Rau, P.; Retière, F.; Rielage, K.; Schnee, R.; Seibert, S.; Skensved, P.; Sonley, T.; Vázquez-Jáuregui, E.; Veloce, L.; Walding, J.; Wang, B.; Wang, J.; Ward, M.; Zhang, C.
2015-05-01
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.
Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; ...
2017-12-01
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics include resistive voltage dividers on the PMTs,more » custom pre-amplifiers mounted directly on the PMT voltage dividers in the liquid argon, and custom amplifier/discriminators (at room temperature). After amplification, the PMT signals are digitized in CAEN waveform digitizers, and CAEN logic modules are used to construct the trigger, the data acquisition system for the TPC is based on the Fermilab "artdaq" software. The system has been in operation since early 2014.« less
Development of a rapid optic bacteria detecting system based on ATP bioluminescence
NASA Astrophysics Data System (ADS)
Liu, Jun Tao; Luo, JinPing; Liu, XiaoHong; Cai, XinXia
2014-12-01
A rapid optic bacteria detecting system based on the principle of Adenosine triphosphate(ATP) bioluminescence was presented in this paper. This system consisted of bioluminescence-based biosensor and the high-sensitivity optic meter. A photon counting photomultiplier tube (PMT) module was used to improve the detection sensitivity, and a NIOS II/f processor based on a Field Programmable Gate Array(FPGA) was used to control the system. In this work, Micrococcus luteus were chosen as the test sample. Several Micrococcus luteus suspension with different concentration was tested by both T2011 and plate counting method. By comparing the two group results, an calibration curve was obtained from the bioluminescence intensity for Micrococcus luteus in the range of 2.3×102 ~ 2.3×106 CFU/mL with a good correlation coefficient of 0.960. An impacting Air microorganism sampler was used to capture Airborne Bacteria, and 8 samples were collected in different place. The TBC results of 8 samples by T2011 were between 10 ~ 2×103 cfu/mL, consistent with that of plate counting method, which indicated that 8 samples were between 10 ~ 3×103 cfu/mL. For total airborne bacteria count was small, correlation coefficient was poor. Also no significant difference was found between T2011 and plate counting method by statistical analyses.
Recent developments with microchannel-plate PMTs
NASA Astrophysics Data System (ADS)
Lehmann, A.; Böhm, M.; Britting, A.; Eyrich, W.; Pfaffinger, M.; Uhlig, F.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Zühlsdorf, M.; Düren, M.; Etzelmüller, E.; Föhl, K.; Hayrapetyan, A.; Kröck, B.; Merle, O.; Rieke, J.; Schmidt, M.; Wasem, T.; Cowie, E.; Keri, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.
2017-12-01
Microchannel-plate (MCP) PMTs are the favored photon sensors for the DIRC detectors of the PANDA experiment at FAIR. Until recently the main drawback of MCP-PMTs were serious aging effects which led to a limited lifetime due to a rapidly decreasing quantum efficiency (QE) of the photo cathode (PC) as the integrated anode charge (IAC) increased. In the latest models of PHOTONIS and Hamamatsu an innovative atomic layer deposition (ALD) technique is applied to overcome these limitations. During the last five years comprehensive aging tests with ALD coated MCP-PMTs were performed and the results were compared to tubes treated with other techniques. The QE in dependence of the IAC was measured as a function of the wavelength and the position across the PC. For the best performing tubes the lifetime improvement in comparison to the older MCP-PMTs is a factor of > 50 based on an IAC of meanwhile > 10 C /cm2 . In addition, the performance results of a new 2-in. ALD coated MCP-PMT prototype from Hamamatsu with a very high position resolution (128×6 anode pixels) is presented and the first conclusions from investigations concerning the PC aging mechanism will be discussed.
Attenuated enzootic (pestoides) isolates of Yersinia pestis express active aspartase.
Bearden, Scott W; Sexton, Christopher; Pare, Joshua; Fowler, Janet M; Arvidson, Cindy G; Yerman, Lyudmyla; Viola, Ronald E; Brubaker, Robert R
2009-01-01
It is established that Yersinia pestis, the causative agent of bubonic plague, recently evolved from enteropathogenic Yersinia pseudotuberculosis by undergoing chromosomal degeneration while acquiring two unique plasmids that facilitate tissue invasion (pPCP) and dissemination by fleabite (pMT). Thereafter, plague bacilli spread from central Asia to sylvatic foci throughout the world. These epidemic isolates exhibit a broad host range including man as opposed to enzootic (pestoides) variants that remain in ancient reservoirs where infection is limited to muroid rodents. Cells of Y. pseudotuberculosis are known to express glucose-6-phosphate dehydrogenase (Zwf) and aspartase (AspA); these activities are not detectable in epidemic Y. pestis due to missense mutations (substitution of proline for serine at amino position 155 of Zwf and leucine for valine at position 363 of AspA). In this study, functional Zwf was found in pestoides strains E, F and G but not seven other enzootic isolates; enzymic activity was associated with retention of serine at amino acid position 155. Essentially, full AspA activity occurred in pestoides isolates where valine (pestoides A, B, C and D) or serine (pestoides E, F, G and I) occupied position 363. Reduced activity occurred in strains Angola and A16, which contained phenylalanine at this position. The kcat but not Km of purified AspA from strain Angola was significantly reduced. In this context, aspA of the recently described attenuated enzootic microtus biovar encodes active valine at position 363, further indicating that functional AspA is a biomarker for avirulence of Y. pestis in man.
VUV light reflectivity measurements from PTFE in Liquid Xenon for the LZ Dark Matter experiment
NASA Astrophysics Data System (ADS)
Pushkin, Kirill; LZ Collaboration
2016-03-01
The LUX-Zeplin (LZ) collaboration is the next generation of the experiment to search for Dark Matter in the Universe with a dual-phase detector based on liquid xenon (LXe) with a target mass of 7 ton. LXe dual phase detectors are very sensitive probes to search for WIMP dark matter interactions. The LZ collaboration is conducting R&D to study VUV light reflectivity from PTFE (Teflon) in LXe. Teflon is used in dual phase detectors both as an electrical insulator and as reflector of VUV scintillation light (~175 nm) to improve photon detection with photomultiplier tubes (PMTs). However, experimental data for the reflectance of VUV light from PTFE in LXe is not sufficiently conclusive. We present a new technique of measuring the light reflectivity from PTFE by varying the fractional area of the PMT in the detector. PTFE reflectivity measurements were performed as a function of Teflon wall thickness in the range of 2 mm to 9.5 mm. The method, apparatus and experimental results will be presented.
NASA Astrophysics Data System (ADS)
Samtleben, Dorothea F. E.
2016-04-01
Neutrinos created in interactions of cosmic rays with the atmosphere can serve as a powerful tool to unveil the neutrino mass hierarchy (NMH). At low energies, around a few GeV, matter effects from the transition through the Earth are expected to imprint a distinct but also subtle signature on the oscillation pattern, specific to the ordering of the neutrino masses. KM3NeT/ORCA (Oscillations Research with Cosmics in the Abyss), a densely instrumented building block of the upcoming KM3NeT neutrino telescope, will be designated to measuring this signature in the Mediterranean Sea. Using detailed simulations the sensitivity towards this signature has been evaluated. The multi-PMT detectors allow in the water for an accurate reconstruction of GeV neutrino event signatures and distinction of neutrino flavours. For the determination of the mass hierarchy a median significance of 2-6σ has been estimated for three years of data taking, depending on the actual hierarchy and the oscillation parameters. At the same time the values of several oscillation parameters like θ23 will be determined to unprecedented precision.
Focal Plane Detectors for the Advanced Gamma-Ray Imaging System (AGIS)
NASA Astrophysics Data System (ADS)
Otte, A. N.; Byrum, K.; Drake, G.; Falcone, A.; Funk, S.; Horan, D.; Mukherjee, R.; Smith, A.; Tajima, H.; Wagner, R. G.; Williams, D. A.
2008-12-01
The Advanced Gamma-Ray Imaging System (AGIS) is a concept for the next generation observatory in ground-based very high energy gamma-ray astronomy. Design goals are ten times better sensitivity, higher angular resolution, and a lower energy threshold than existing Cherenkov telescopes. Simulations show that a substantial improvement in angular resolution may be achieved if the pixel diameter is reduced to the order of 0.05 deg, i.e. two to three times smaller than the pixel diameter of current Cherenkov telescope cameras. At these dimensions, photon detectors with smaller physical dimensions can be attractive alternatives to the classical photomultiplier tube (PMT). Furthermore, the operation of an experiment with the size of AGIS requires photon detectors that are among other things more reliable, more durable, and possibly higher efficiency photon detectors. Alternative photon detectors we are considering for AGIS include both silicon photomultipliers (SiPMs) and multi-anode photomultipliers (MAPMTs). Here we present results from laboratory testing of MAPMTs and SiPMs along with results from the first incorporation of these devices into cameras on test bed Cherenkov telescopes.
NASA Technical Reports Server (NTRS)
Howell, L. W.; Kennel, H. F.
1984-01-01
The Space Telescope (ST) is subjected to charged particle strikes in its space environment. ST's onboard fine guidance sensors utilize multiplier phototubes (PMT) for attitude determination. These tubes, when subjected to charged particle strikes, generate spurious photons in the form of Cerenkov radiation and fluorescence which give rise to unwanted disturbances in the pointing of the telescope. A stochastic model for the number of these spurious photons which strike the photocathode of the multiplier phototube which in turn produce the unwanted photon noise are presented. The model is applicable to both galactic cosmic rays and charged particles trapped in the Earth's radiation belts. The model which was programmed allows for easy adaption to a wide range of particles and different parameters for the phototube of the multiplier. The probability density functions for photons noise caused by protons, alpha particles, and carbon nuclei were using thousands of simulated strikes. These distributions are used as part of an overall ST dynamics simulation. The sensitivity of the density function to changes in the window parameters was also investigated.
NASA Technical Reports Server (NTRS)
Howell, L. W.; Kennel, H. F.
1986-01-01
The Space Telescope (ST) is subjected to charged particle strikes in its space environment. ST's onboard fine guidance sensors utilize multiplier phototubes (PMT) for attitude determination. These tubes, when subjected to charged particle strikes, generate spurious photons in the form of Cerenkov radiation and fluorescence which give rise to unwanted disturbances in the pointing of the telescope. A stochastic model for the number of these spurious photons which strike the photocathodes of the multiplier phototube which in turn produce the unwanted photon noise are presented. The model is applicable to both galactic cosmic rays and charged particles trapped in the earth's radiation belts. The model which was programmed allows for easy adaption to a wide range of particles and different parameters for the phototube of the multiplier. The probability density functions for photons noise caused by protons, alpha particles, and carbon nuclei were using thousands of simulated strikes. These distributions are used as part of an overall ST dynamics simulation. The sensitivity of the density function to changes in the window parameters was also investigated.
Low-background Gamma Spectroscopy at Sanford Underground Laboratory
NASA Astrophysics Data System (ADS)
Chiller, Christopher; Alanson, Angela; Mei, Dongming
2014-03-01
Rare-event physics experiments require the use of material with unprecedented radio-purity. Low background counting assay capabilities and detectors are critical for determining the sensitivity of the planned ultra-low background experiments. A low-background counting, LBC, facility has been built at the 4850-Level Davis Campus of the Sanford Underground Research Facility to perform screening of material and detector parts. Like many rare event physics experiments, our LBC uses lead shielding to mitigate background radiation. Corrosion of lead brick shielding in subterranean installations creates radon plate-out potential as well as human risks of ingestible or respirable lead compounds. Our LBC facilities employ an exposed lead shield requiring clean smooth surfaces. A cleaning process of low-activity silica sand blasting and borated paraffin hot coating preservation was employed to guard against corrosion due to chemical and biological exposures. The resulting lead shield maintains low background contribution integrity while fully encapsulating the lead surface. We report the performance of the current LBC and a plan to develop a large germanium well detector for PMT screening. Support provided by Sd governors research center-CUBED, NSF PHY-0758120 and Sanford Lab.
24 CFR Appendix E to Part 3500 - Arithmetic Steps
Code of Federal Regulations, 2010 CFR
2010-04-01
... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Arithmetic Steps E Appendix E to...—Arithmetic Steps I. Example Illustrating Aggregate Analysis: ASSUMPTIONS: Disbursements: $360 for school... Payment: July 1 Step 1—Initial Trial Balance Aggregate pmt disb bal Jun 0 0 0 Jul 130 500 −370 Aug 130 0...
ERIC Educational Resources Information Center
Warren, Steven F.; Fey, Marc E.; Finestack, Lizbeth, H.; Brady, Nancy C.; Bredin-Oja, Shelley L.; Fleming, Kandace K.
2008-01-01
Purpose: To evaluate the longitudinal effects of a 6-month course of responsivity education (RE)/prelinguistic milieu teaching (PMT) for young children with developmental delay. Method: Fifty-one children, age 24-33 months, with fewer than 10 expressive words were randomly assigned to early-treatment/no-treatment groups. All treatment was added as…
ERIC Educational Resources Information Center
Maliken, Ashley C.; Katz, Lynn Fainsilber
2013-01-01
Parenting interventions, particularly those categorized as parent management training (PMT), have a large evidence base supporting their effectiveness with most families who present for treatment of childhood behavior problems. However, data suggest that PMTs are not effective at treating all families who seek services. Parental psychopathology…
NASA Astrophysics Data System (ADS)
Tai, Yuan-Chuan; Chatziioannou, Arion F.; Yang, Yongfeng; Silverman, Robert W.; Meadors, Ken; Siegel, Stefan; Newport, Danny F.; Stickel, Jennifer R.; Cherry, Simon R.
2003-06-01
MicroPET II is a second-generation animal PET scanner designed for high-resolution imaging of small laboratory rodents. The system consists of 90 scintillation detector modules arranged in three contiguous axial rings with a ring diameter of 16.0 cm and an axial length of 4.9 cm. Each detector module consists of a 14 × 14 array of lutetium oxyorthosilicate (LSO) crystals coupled to a multi-channel photomultiplier tube (MC-PMT) through a coherent optical fibre bundle. Each LSO crystal element measures 0.975 mm × 0.975 mm in cross section by 12.5 mm in length. A barium sulphate reflector material was used between LSO elements leading to a detector pitch of 1.15 mm in both axial and transverse directions. Fused optical fibre bundles were made from 90 µm diameter glass fibres with a numerical aperture of 0.56. Interstitial extramural absorber was added between the fibres to reduce optical cross talk. A charge-division readout circuit was implemented on printed circuit boards to decode the 196 crystals in each array from the outputs of the 64 anode signals of the MC-PMT. Electronics from Concorde Microsystems Inc. (Knoxville, TN) were used for signal amplification, digitization, event qualification, coincidence processing and data capture. Coincidence data were passed to a host PC that recorded events in list mode. Following acquisition, data were sorted into sinograms and reconstructed using Fourier rebinning and filtered backprojection algorithms. Basic evaluation of the system has been completed. The absolute sensitivity of the microPET II scanner was 2.26% at the centre of the field of view (CFOV) for an energy window of 250-750 keV and a timing window of 10 ns. The intrinsic spatial resolution of the detectors in the system averaged 1.21 mm full width at half maximum (FWHM) when measured with a 22Na point source 0.5 mm in diameter. Reconstructed image resolution ranged from 0.83 mm FWHM at the CFOV to 1.47 mm FWHM in the radial direction, 1.17 mm FWHM in the tangential direction and 1.42 mm FWHM in the axial direction at 1 cm offset from the CFOV. These values represent highly significant improvements over our earlier microPET scanner (approximately fourfold sensitivity increase and 25-35% improvement in linear spatial resolution under equivalent operating conditions) and are expected to be further improved when the system is fully optimized. This work was originally conducted at UCLA, Crump Institute for Molecular Imaging, and was continued and completed at UC Davis, Department of Biomedical Engineering.
Maximum-Likelihood Estimation With a Contracting-Grid Search Algorithm
Hesterman, Jacob Y.; Caucci, Luca; Kupinski, Matthew A.; Barrett, Harrison H.; Furenlid, Lars R.
2010-01-01
A fast search algorithm capable of operating in multi-dimensional spaces is introduced. As a sample application, we demonstrate its utility in the 2D and 3D maximum-likelihood position-estimation problem that arises in the processing of PMT signals to derive interaction locations in compact gamma cameras. We demonstrate that the algorithm can be parallelized in pipelines, and thereby efficiently implemented in specialized hardware, such as field-programmable gate arrays (FPGAs). A 2D implementation of the algorithm is achieved in Cell/BE processors, resulting in processing speeds above one million events per second, which is a 20× increase in speed over a conventional desktop machine. Graphics processing units (GPUs) are used for a 3D application of the algorithm, resulting in processing speeds of nearly 250,000 events per second which is a 250× increase in speed over a conventional desktop machine. These implementations indicate the viability of the algorithm for use in real-time imaging applications. PMID:20824155
Corrected Position Estimation in PET Detector Modules With Multi-Anode PMTs Using Neural Networks
NASA Astrophysics Data System (ADS)
Aliaga, R. J.; Martinez, J. D.; Gadea, R.; Sebastia, A.; Benlloch, J. M.; Sanchez, F.; Pavon, N.; Lerche, Ch.
2006-06-01
This paper studies the use of Neural Networks (NNs) for estimating the position of impinging photons in gamma ray detector modules for PET cameras based on continuous scintillators and Multi-Anode Photomultiplier Tubes (MA-PMTs). The detector under study is composed of a 49/spl times/49/spl times/10 mm/sup 3/ continuous slab of LSO coupled to a flat panel H8500 MA-PMT. Four digitized signals from a charge division circuit, which collects currents from the 8/spl times/8 anode matrix of the photomultiplier, are used as inputs to the NN, thus reducing drastically the number of electronic channels required. We have simulated the computation of the position for 511 keV gamma photons impacting perpendicularly to the detector surface. Thus, we have performed a thorough analysis of the NN architecture and training procedures in order to achieve the best results in terms of spatial resolution and bias correction. Results obtained using GEANT4 simulation toolkit show a resolution of 1.3 mm/1.9 mm FWHM at the center/edge of the detector and less than 1 mm of systematic error in the position near the edges of the scintillator. The results confirm that NNs can partially model and correct the non-uniform detector response using only the position-weighted signals from a simple 2D DPC circuit. Linearity degradation for oblique incidence is also investigated. Finally, the NN can be implemented in hardware for parallel real time corrected Line-of-Response (LOR) estimation. Results on resources occupancy and throughput in FPGA are presented.
Asking the Right Questions: Action Learning and PMT 401
2016-08-01
program aimed at improving leadership, critical thinking , problem solving and decisionmaking skills. Participants in this rigorous, inresidence...problem • Skill Development • Urgent and complex problems requiring unique systems thinking • Groups charged with implementing the solution as...most pressing organi zational issues: problem solving, organizational learning, team building, leadership development, and professional growth and
Kazdin, Alan E
2018-01-01
The intervention work of our clinical-research team has focused on the treatment of children and young adolescents referred for Conduct Disorder or Oppositional Defiant Disorder. We have evaluated two interventions: parent management training (PMT) and cognitive problem-solving skills training in several randomized controlled clinical trials. Our findings have indicated the treatments, alone or in combination, produce reliable and significant reductions in oppositional, aggressive, and antisocial behaviour and increases in prosocial behaviour among children. Parent dysfunction (depression, multiple symptom domains) and stress decline and family relations improve as well. Apart from outcome studies, we have studied the therapeutic alliance, factors that influence dropping out and retaining cases, and variations of treatment delivery (e.g., computer based, reduced therapist contact). The article considers challenges in conducting controlled trials in clinic settings (e.g., recruiting cases, maintaining treatment integrity, securing funding) and activities related to implementation that are not easily covered within the confines of research articles. The article ends with a discussion of one of the treatments (PMT) and the broad role it can play in treatment, prevention, and help with many parenting challenges of everyday life.
Application of the protection motivation theory to genetic testing for breast cancer risk.
Helmes, Almut W
2002-11-01
Many women, even women at low risk, are interested in genetic testing for breast cancer risk. However, the test has little to offer for women at low to moderate risk. We applied the Protection Motivation Theory (PMT) to investigate predictors of women's motivation to obtain such a test. Women at low to moderate risk (n = 330) were recruited through a physician network. They received an informational letter by mail and completed a telephone survey and a written baseline questionnaire. Structural equation analyses with motivation to test as the outcome variable showed that the full model was not supported by the data. However, modifications to the model resulted in good model fit and explained 51% of the variance. Women with increased breast cancer worries, which were influenced by perceived risk, and women who saw more disadvantages of not getting tested showed more motivation to pursue testing. Women who saw more advantages of not getting tested showed less motivation. Applying the PMT was helpful in determining factors that play a role in women's intentions to obtain genetic testing. Counseling should aim at decreasing perceived risk and breast cancer worries and include a discussion of the consequences of not getting tested.
Neutron detection using a water Cherenkov detector with pure water and a single PMT
NASA Astrophysics Data System (ADS)
Sidelnik, Iván; Asorey, Hernán; Blostein, Juan Jerónimo; Gómez Berisso, Mariano
2017-12-01
We present the performance of a novel neutron detector based on a water Cherenkov detector (WCD) employing pure water and a single photomultiplier tube (PMT). The experiments presented in this work were performed using 241AmBe and 252Cf neutron sources in different neutron moderator and shielding configurations. We show that fast neutrons from the 241AmBe and 241Cf sources, as well as thermal neutrons from a neutron moderator, despite having different spectral characteristics, produce essentially the same pulse histogram shape. This characteristic pulse-height histogram shapes are recorded as a clear signature of neutrons with energies lower than ≃ 11 MeV . This is verified in different experimental conditions. Our estimation of the neutron detection efficiency is at the level of (15±5)%, for fast neutrons. Since water is the material employed as active volume, the results of this study are of interest for the construction of low cost and large active volume neutron detectors for various applications. Of special importance are those related with space weather phenomena monitoring as well as those for the detection of fissile special nuclear material, including uranium or plutonium.
Implementing a Java Based GUI for RICH Detector Analysis
NASA Astrophysics Data System (ADS)
Lendacky, Andrew; Voloshin, Andrew; Benmokhtar, Fatiha
2016-09-01
The CLAS12 detector at Thomas Jefferson National Accelerator Facility (TJNAF) is undergoing an upgrade. One of the improvements is the addition of a Ring Imaging Cherenkov (RICH) detector to improve particle identification in the 3-8 GeV/c momentum range. Approximately 400 multi anode photomultiplier tubes (MAPMTs) are going to be used to detect Cherenkov Radiation in the single photoelectron spectra (SPS). The SPS of each pixel of all MAPMTs have been fitted to a mathematical model of roughly 45 parameters for 4 HVs, 3 OD. Out of those parameters, 9 can be used to evaluate the PMTs performance and placement in the detector. To help analyze data when the RICH is operational, a GUI application was written in Java using Swing and detector packages from TJNAF. To store and retrieve the data, a MySQL database program was written in Java using the JDBC package. Using the database, the GUI pulls the values and produces histograms and graphs for a selected PMT at a specific HV and OD. The GUI will allow researchers to easily view a PMT's performance and efficiency to help with data analysis and ring reconstruction when the RICH is finished.
NASA Astrophysics Data System (ADS)
Szelc, A. M.; Canci, N.; Cavanna, F.; Cortopassi, A.; D'Incecco, M.; Mini, G.; Pietropaolo, F.; Romboli, A.; Segreto, E.; Acciarri, R.
A new generation Waveform Digitizer board as been recently made available on the market by CAEN. The new board CAEN V1751 with 8 Channels per board, 10 bit, 1 GS/s Flash ADC Waveform Digitizer (or 4 channel, 10 bit, 2 GS/s Flash ADC Waveform Digitizer -Dual Edge Sampling mode) with threshold and Auto-Trigger capabilities provides an ideal (relatively low-cost) solution for reading signals from liquid Argon detectors for Dark Matter search equipped with an array of PMTs for the detection of scintillation light. The board was extensively used in real experimental conditions to test its usefulness for possible future uses and to compare it with a state of the art digital oscilloscope. As results, PMT Signal sampling at 1 or 2 GS/s is appropriate for the reconstruction of the fast component of the signal scintillation in Argon (characteristic time of about 4 ns) and the extended dynamic range, after a small customization, allows for the detection of signals in the range of energy needed. The bandwidth is found to be adequate and the intrinsic noise is very low.
Agishev, Ravil; Comerón, Adolfo; Rodriguez, Alejandro; Sicard, Michaël
2014-05-20
In this paper, we show a renewed approach to the generalized methodology for atmospheric lidar assessment, which uses the dimensionless parameterization as a core component. It is based on a series of our previous works where the problem of universal parameterization over many lidar technologies were described and analyzed from different points of view. The modernized dimensionless parameterization concept applied to relatively new silicon photomultiplier detectors (SiPMs) and traditional photomultiplier (PMT) detectors for remote-sensing instruments allowed predicting the lidar receiver performance with sky background available. The renewed approach can be widely used to evaluate a broad range of lidar system capabilities for a variety of lidar remote-sensing applications as well as to serve as a basis for selection of appropriate lidar system parameters for a specific application. Such a modernized methodology provides a generalized, uniform, and objective approach for evaluation of a broad range of lidar types and systems (aerosol, Raman, DIAL) operating on different targets (backscatter or topographic) and under intense sky background conditions. It can be used within the lidar community to compare different lidar instruments.
Chien, Po-Jen; Suzuki, Takuma; Tsujii, Masato; Ye, Ming; Toma, Koji; Arakawa, Takahiro; Iwasaki, Yasuhiko; Mitsubayashi, Kohji
2017-05-15
Exhaled breath analysis has attracted lots of researchers attention in the past decades due to its advantages such as its non-invasive property and the possibility of continuous monitoring. In addition, several volatile organic compounds in breath have been identified as biomarkers for some diseases. Particularly, studies have pointed out that concentration of isopropanol (IPA) in exhaled air might relate with certain illnesses such as liver disease, chronic obstructive pulmonary (COPD), and lung cancer. In this study, a highly sensitive and selective biochemical gas sensor (bio-sniffer) for the breath IPA concentration determination was constructed and optimized. This bio-sniffer measures the concentration of IPA according to the fluorescence intensity of oxidized nicotinamide adenine dinucleotide (NADH), which was produced by an enzymatic reaction of secondary alcohol dehydrogenase (S-ADH). The NADH detection system employed an UV-LED as the excitation light, and a highly sensitive photomultiplier tube (PMT) as a fluorescence intensity detector. A gas-sensing region was developed using an optical fiber probe equipped with a flow-cell and enzyme immobilized membrane, and connected to the NADH measurement system. The calibration range of the IPA bio-sniffer was confirmed from 1ppb to 9060ppb that was comparable to other IPA analysis methods. The results of the analysis of breath IPA concentration in healthy subjects using the bio-sniffer showed a mean concentration of 16.0ppb, which was similar to other studies. These results have demonstrated that this highly sensitive and selective bio-sniffer could be used to measure the IPA in exhaled air, and it is expected to apply for breath IPA research and investigation of biomarkers for clinical diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.
The research of data acquisition system for Raman spectrometer
NASA Astrophysics Data System (ADS)
Cui, Xiao; Guo, Pan; Zhang, Yinchao; Chen, Siying; Chen, He; Chen, Wenbo
2011-11-01
Raman spectrometer has been widely used as an identification tool for analyzing material structure and composition in many fields. However, Raman scattering echo signal is very weak, about dozens of photons at most in one laser plus signal. Therefore, it is a great challenge to design a Raman spectrum data acquisition system which could accurately receive the weak echo signal. The system designed in this paper receives optical signals with the principle of photon counter and could detect single photon. The whole system consists of a photoelectric conversion module H7421-40 and a photo counting card including a field programmable gate array (FPGA) chip and a PCI9054 chip. The module H7421-40 including a PMT, an amplifier and a discriminator has high sensitivity on wavelength from 300nm to 720nm. The Center Wavelength is 580nm which is close to the excitation wavelength (532nm), QE 40% at peak wavelength, Count Sensitivity is 7.8*105(S-1PW-1) and Count Linearity is 1.5MHZ. In FPGA chip, the functions are divided into three parts: parameter setting module, controlling module, data collection and storage module. All the commands, parameters and data are transmitted between FPGA and computer by PCI9054 chip through the PCI interface. The result of experiment shows that the Raman spectrum data acquisition system is reasonable and efficient. There are three primary advantages of the data acquisition system: the first one is the high sensitivity with single photon detection capability; the second one is the high integrated level which means all the operation could be done by the photo counting card; and the last one is the high expansion ability because of the smart reconfigurability of FPGA chip.
NASA Astrophysics Data System (ADS)
Repasky, K. S.; Hoffman, D. S.; Reagan, J. A.; Carlsten, J.
2010-12-01
Aerosols are an important constituent in atmospheric composition affecting climate, weather, and air quality. Active remote sensing instruments provide tools for in-situ studies of atmospheric aerosols that can help understand the role of aerosols on the radiative forcing of the climate system. In this paper, the design and initial performance of a high spectral resolution lidar (HSRL) based on a unique confocal cavity for optically filtering the aerosol and molecular returns is presented. An injection seeded pulsed Nd:YAG laser with a fundamental and frequency doubled output is used as the laser transmitter for the HSRL. A small portion of fiber coupled injection seeded signal at 1064 nm is split before the laser oscillator and, after modulation using an acousto-optic modulator, is used to produce a discriminating signal for locking a confocal cavity that is resonant at the 1064 and 532 nm wavelengths to the injection seeded source. Light scattered in the atmosphere is collected using a commercial telescope. After the telescope, the 1064 nm light is split from the 532 nm light using a dielectric mirror with the 1064 nm light monitored using a PMT. The 532 nm light is launched into a multimode fiber. The output from the fiber is next incident on a beamsplitter with part of the light sent to a PMT to monitor the total return for the 532 nm channel. The light that passes through the beamsplitter is mode matched into a confocal optical cavity that allows the light scattered by the atmospheric aerosols to be transmitted while the light scattered from the atmospheric molecules is reflected. The transmitted light from the aerosol scattering is incident on a PMT while the reflected molecular signal is incident on a PMT. The transmission of the confocal cavity is monitored before and after the data collection using a continuous wave frequency doubled Nd:YAG laser that is fiber coupled. Data is collected and processed in the following manner. Each of the four voltage signals from the PMT’s are monitored using a high speed A/D card. The inversion of the 1064 nm return signal is completed using the Fernald inversion technique with the additional constraint of the aerosol optical depth. The HSRL 532 nm signal is inverted using a Rayleigh backscatter model along with the inversion techniques described by Shipley et al. (Applied Optics, V22, N23, 3716-3724, 1983) and Sroga et al. (Applied Optics, V22, N23, 3725-3732, 1983). This presentation will focus on the design of the confocal optical filter, the locking of the confocal optical filter to the laser transmitter, and the performance of the high spectral resolution channel at 532 nm. Data will be presented showing the molecular returns, the aerosol returns and the range resolved lidar ratio.
NASA Astrophysics Data System (ADS)
Soukup, B.; Johnson, W.; Repasky, K. S.; Carlsten, J. L.
2013-12-01
A scanning differential absorption lidar (DIAL) instrument for carbon sequestration site monitoring is under development and testing at Montana State University. The laser transmitter uses two tunable discrete mode laser diodes (DMLD) operating in the continuous wave (cw) mode with one locked to the on-line absorption wavelength at 1571.4067 nm and the second operating at the off-line wavelength at 1571.2585 nm. Two in-line fiber optic switches are used to switch between on-line and off-line operation. After the fiber optic switches, an acousto-optic modulator (AOM) is used to generate a pulse train used to injection seed an erbium doped fiber amplifier (EDFA) to produce eye-safe laser pulses with maximum pulse energies of 66 J and a pulse repetition frequency of 15 kHz. The DIAL receiver uses a 28 cm diameter Schmidt-Cassegrain telescope to collect that backscattered light, which is then monitored using a fiber coupled photo-multiplier tube (PMT) module operating in the photon counting mode. The PMT has a 3% quantum efficiency, a dark count rate of 90 kHz, and a maximum count rate of 1 MHz. Recently, a fiber coupled avalanche photodiode (APD) operating in the geiger mode has been incorporated into the DIAL receiver. The APD has a quantum efficiency of 10%, a dark count rate of 10 kHz, and a maximum count rate of 1 MHz and provides a much larger dynamic range than the PMT. Both the PMT and APD provide TTL logic pulses that are monitored using a multichannel scaler card used to count the return photons as a function of time of flight and are thus interchangeable. The DIAL instrument was developed at the 1.571 m wavelength to take advantage of commercial-off-the-shelf components. The instrument is operated using a custom Labview program that switches to the DMLD operating at the on-line wavelength, locks this laser to a user defined wavelength setting, and collects return signals for a user defined time. The control program switches to the DMLD operating at the off-line wavelength where data is again collected for a user defined time. The control program repeats this process until stopped by the operator. The DIAL instrument has been operated at the Zero Emission Research Technology (ZERT) field site located on the Montana State University campus and at the Big Sky Carbon Sequestration Partnership site located in north-central Montana. Data collected by the DIAL instrument at both field sites demonstrate that the DIAL is capable of retrieving night time CO2 number density profiles out to a range of 2.5 km with a 150 m range resolution. The DIAL retrievals are validated using a co-located Li-COR 820 gas analyzer placed along the DIAL optical path allowing comparison at a single range as a function of time.
De Steur, Hans; Gellynck, Xavier; Makokha, Anselimo
2016-01-01
BACKGROUND/OBJECTIVES Despite successes recorded in combating iodine deficiency, more than 2 billion people are still at risk of iodine deficiency disorders. Rural landlocked and mountainous areas of developing countries are the hardest hit, hence the need to explore and advance novel strategies such as biofortification. SUBJECTS/METHODS We evaluated adoption, purchase, and consumption of iodine biofortified vegetable legumes (IBVL) using the theory of protection motivations (PMT) integrated with an economic valuation technique. A total of 1,200 participants from three land-locked locations in East Africa were recruited via multi-stage cluster sampling, and data were collected using two, slightly distinct, questionnaires incorporating PMT constructs. The survey also elicited preferences for iodine biofortified foods when offered at a premium or discount. Determinants of protection motivations and preferences for iodine biofortified foods were assessed using path analysis modelling and two-limit Tobit regression, respectively. RESULTS Knowledge of iodine, iodine-health link, salt iodization, and biofortification was very low, albeit lower at the household level. Iodine and biofortification were not recognized as nutrient and novel approaches, respectively. On the other hand, severity, fear, occupation, knowledge, iodine status, household composition, and self-efficacy predicted the intention to consume biofortified foods at the household level; only vulnerability, self-efficacy, and location were the most crucial elements at the school level. In addition, results demonstrated a positive willingness-to-pay a premium or acceptance of a lesser discount for biofortification. Furthermore, preference towards iodine biofortified foods was a function of protection motivations, severity, vulnerability, fear, response efficacy, response cost, knowledge, iodine status, gender, age. and household head. CONCLUSIONS Results lend support for prevention of iodine deficiency in unprotected populations through biofortification; however 'threat' appraisal and socio-economic predictors are decisive in designing nutrition interventions and stimulating uptake of biofortification. In principle, the contribution is threefold: 1) Successful application of the integrated model to guide policy formulation; 2) Offer guidance to stakeholders to identify and tap niche markets; 3) stimulation of rural economic growth around school feeding programmes. PMID:26865917
Detection of Yersinia pestis using real-time PCR in patients with suspected bubonic plague.
Riehm, Julia M; Rahalison, Lila; Scholz, Holger C; Thoma, Bryan; Pfeffer, Martin; Razanakoto, Léa Mamiharisoa; Al Dahouk, Sascha; Neubauer, Heinrich; Tomaso, Herbert
2011-02-01
Yersinia (Y.) pestis, the causative agent of plague, is endemic in natural foci of Asia, Africa, and America. Real-time PCR assays have been described as rapid diagnostic tools, but so far none has been validated for its clinical use. In a retrospective clinical study we evaluated three real-time PCR assays in two different assay formats, 5'-nuclease and hybridization probes assays. Lymph node aspirates from 149 patients from Madagascar with the clinical diagnosis of bubonic plague were investigated for the detection of Y. pestis DNA. Results of real-time PCR assays targeting the virulence plasmids pPCP1 (pla gene), and pMT1 (caf1, Ymt genes) were compared with an F1-antigen immunochromatographic test (ICT) and cultivation of the organism. Out of the 149 samples an infection with Y. pestis was confirmed by culture in 47 patients while ICT was positive in 88 including all culture proven cases. The best real-time PCR assay was the 5'-nuclease assay targeting pla which was positive in 120 cases. In conclusion, the 5'-nuclease assay targeting pla can be recommended as diagnostic tool for establishing a presumptive diagnosis when bubonic plague is clinically suspected. Copyright © 2010 Elsevier Ltd. All rights reserved.
Case Study of the U.S. Army’s Should-Cost Management Implementation
2013-12-03
and Pelvic Protection Systems (PPS). After graduating from the Naval Postgraduate School, Major Choi will be assigned to the U.S. Army...Systems PMO Product/Project/Program Management Office PMT Program Management Training POA&M Plan of Action and Milestones POE Program Office...Intelligence, Electronic Warfare and Sensors PEO Simulation, Training , and Instrumentation JPEO Chemical and Biological Defense The researcher
Hydrocarbon-Fueled Scramjet Research at Hypersonic Mach Numbers
2005-03-31
oxide O atomic oxygen 02 molecular oxygen OH hydroxyl radical ppm parts per million PD photodiode PLLF planar laser-induced fluorescence PMT...photomultiplier tube RAM random access memory RANS Reynolds-averaged Navier-Stokes RET rotational energy transfer TDLAS tunable diode laser absorption...here extend this knowledge base to flight at Mach 11.5. Griffiths (2004) used a tunable diode laser absorption spectroscopy ( TDLAS ) system to measure
Wang, Yin-Yin; Li, Jie; Wu, Zeng-Rui; Zhang, Bo; Yang, Hong-Bin; Wang, Qin; Cai, Ying-Chun; Liu, Gui-Xia; Li, Wei-Hua; Tang, Yun
2017-05-01
An increasing number of cases of herb-induced liver injury (HILI) have been reported, presenting new clinical challenges. In this study, taking Polygonum multiflorum Thunb (PmT) as an example, we proposed a computational systems toxicology approach to explore the molecular mechanisms of HILI. First, the chemical components of PmT were extracted from 3 main TCM databases as well as the literature related to natural products. Then, the known targets were collected through data integration, and the potential compound-target interactions (CTIs) were predicted using our substructure-drug-target network-based inference (SDTNBI) method. After screening for hepatotoxicity-related genes by assessing the symptoms of HILI, a compound-target interaction network was constructed. A scoring function, namely, Ascore, was developed to estimate the toxicity of chemicals in the liver. We conducted network analysis to determine the possible mechanisms of the biphasic effects using the analysis tools, including BiNGO, pathway enrichment, organ distribution analysis and predictions of interactions with CYP450 enzymes. Among the chemical components of PmT, 54 components with good intestinal absorption were used for analysis, and 2939 CTIs were obtained. After analyzing the mRNA expression data in the BioGPS database, 1599 CTIs and 125 targets related to liver diseases were identified. In the top 15 compounds, seven with Ascore values >3000 (emodin, quercetin, apigenin, resveratrol, gallic acid, kaempferol and luteolin) were obviously associated with hepatotoxicity. The results from the pathway enrichment analysis suggest that multiple interactions between apoptosis and metabolism may underlie PmT-induced liver injury. Many of the pathways have been verified in specific compounds, such as glutathione metabolism, cytochrome P450 metabolism, and the p53 pathway, among others. Hepatitis symptoms, the perturbation of nine bile acids and yellow or tawny urine also had corresponding pathways, justifying our method. In conclusion, this computational systems toxicology method reveals possible toxic components and could be very helpful for understanding the mechanisms of HILI. In this way, the method might also facilitate the identification of novel hepatotoxic herbs.
Secondary Emission Calorimeter Sensor Development
NASA Astrophysics Data System (ADS)
Winn, David R.; Onel, Yasar
2012-12-01
In a Secondary Emission electron(SEe) detector module, Secondary Emission electrons (SEe) are generated from an SE surface/cathode, when charged hadronic or electromagnetic particles, particularly shower particles, penetrate an SE sampling module placed between absorber materials (Fe, Cu, Pb, W etc) in calorimeters. The SE cathode is a thin (10-50 nm thick) film (simple metal-oxides, or other higher yield materials) on the surface of a metal plate, which serves as the entrance “window” to a compact vacuum vessel (metal or metal-ceramic); this SE film cathode is analogous to a photocathode, and the SEe are similar to p.e., which are then amplified by dynodes, also is in a PMT. SE sensor modules can make use of electrochemically etched/machined or laser-cut metal mesh dynode sheets, as large as ~30 cm square, to amplify the Secondary Emission Electrons (SEe), much like those that compact metal mesh or mesh dynode PMT's use to amplify p.e.'s. The construction requirements easier than a PMT, since the entire final assembly can be done in air; there are no critical controlled thin film depositions, cesiation or other oxygen-excluded processes or other required vacuum activation, and consequently bake-out can be a refractory temperatures; the module is sealed by normal vacuum techniques (welding or brazing or other high temperature joinings), with a simple final heated vacuum pump-out and tip-off. The modules envisioned are compact, high gain, high speed, exceptionally radiation damage resistant, rugged, and cost effective, and can be fabricated in arbitrary tileable shapes. The SE sensor module anodes can be segmented transversely to sizes appropriate to reconstruct electromagnetic cores with high precision. The GEANT4 and existing calorimeter data estimated calorimeter response performance is between 35-50 Secondary Emission electrons per GeV, in a 1 cm thick Cu absorber calorimeter, with a gain per SEe > 105 per SEe, and an e/pi<1.2. The calorimeter pulse width is estimated to be <15 ns. With fine mesh sampling only (no thick absorbers) the resolution is ~25 MeV at 1 GeV.
Performance of the Tachyon Time-of-Flight PET Camera
NASA Astrophysics Data System (ADS)
Peng, Q.; Choong, W.-S.; Vu, C.; Huber, J. S.; Janecek, M.; Wilson, D.; Huesman, R. H.; Qi, Jinyi; Zhou, Jian; Moses, W. W.
2015-02-01
We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 ×25 mm2 side of 6.15 ×6.15 ×25 mm3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- 20 ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. The results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.
Performance of the Tachyon Time-of-Flight PET Camera.
Peng, Q; Choong, W-S; Vu, C; Huber, J S; Janecek, M; Wilson, D; Huesman, R H; Qi, Jinyi; Zhou, Jian; Moses, W W
2015-02-01
We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 × 25 mm 2 side of 6.15 × 6.15 × 25 mm 3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. The results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.
Performance of the Tachyon Time-of-Flight PET Camera
Peng, Q.; Choong, W.-S.; Vu, C.; Huber, J. S.; Janecek, M.; Wilson, D.; Huesman, R. H.; Qi, Jinyi; Zhou, Jian; Moses, W. W.
2015-01-01
We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon’s detector module is optimized for timing by coupling the 6.15 × 25 mm2 side of 6.15 × 6.15 × 25 mm3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/− ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. The results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3. PMID:26594057
Evaluation of a LiI(Eu) neutron detector with coincident double photodiode readout
NASA Astrophysics Data System (ADS)
Yang, H.; Menaa, N.; Bronson, F.; Kastner, M.; Venkataraman, R.; Mueller, W. F.
2011-10-01
Previous work showed that enriched 6Li halide scintillation crystal is a good candidate for portable neutron-sensitive detectors. Photodiode readout is a good alternative to PMT in compact devices. These detectors are often required to work in presence of a strong gamma background. Therefore, great discrimination against gamma rays is crucial. Because of the high Q-value of the 6Li(n,α) 3H reaction, the light yield of a neutron capture signal corresponds to 3-4 MeV gamma equivalent in spite of the quenching effect of heavily charged particles. As a result, energy discrimination is quite effective against gamma signals generated in thin crystals. However, direct gamma interactions inside the photodiode can create pulses whose amplitude is large enough to interfere with thermal neutron peak. This study shows an innovative design based on coincident readout to solve this problem. In this design, two photodiodes are attached on both sides of the LiI crystal. The output signal is only accepted when both photodiodes give out coincident output. The method is proved to effectively suppress background in the neutron window in a 420 mR/h 137Cs field down to the level of natural background.
Performance of the Tachyon Time-of-Flight PET Camera
Peng, Q.; Choong, W. -S.; Vu, C.; ...
2015-01-23
We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 ×25 mm 2 side of 6.15 ×6.15 ×25 mm 3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according tomore » the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- 20 ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. We find that the results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.« less
Development of an abort gap monitor for the large hadroncollider
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beche, J.-F.; Byrd, J.; De Santis, S.
2004-07-01
The Large Hadron Collider (LHC), presently under construction at CERN, requires monitoring the parasitic charge in the 3.3ms long gap in the machine fill structure. This gap, referred to as the abort gap, corresponds to the raise time of the abort kickers magnets. Any circulating particle present in the abort gap at the time of the kickers firing is lost inside the ring, rather than in the beam dump, and can potentially damage a number of the LHC components. CERN specifications indicate a linear density of 6 x 106 protons over a 100 ns interval as the maximum charge safelymore » allowed to accumulate in the abort gap at 7 TeV. We present a study of an abort gap monitor, based on a photomultiplier tube with a gated microchannel plate, which would allow for detecting such low charge densities by monitoring the synchrotron radiation emitted in the dedicated diagnostics port. We show results of beam test experiments at the Advanced Light Source (ALS) using a Hamamatsu 5961U MCP-PMT, which indicate that such an instrument has the required sensitivity to meet LHC specifications.« less
Localisation of gamma-ray interaction points in thick monolithic CeBr3 and LaBr3:Ce scintillators
NASA Astrophysics Data System (ADS)
Ulyanov, Alexei; Morris, Oran; Roberts, Oliver J.; Tobin, Isaac; Hanlon, Lorraine; McBreen, Sheila; Murphy, David; Nelms, Nick; Shortt, Brian
2017-02-01
Localisation of gamma-ray interaction points in monolithic scintillator crystals can simplify the design and improve the performance of a future Compton telescope for gamma-ray astronomy. In this paper we compare the position resolution of three monolithic scintillators: a 28×28×20 mm3 (length×breadth × thickness) LaBr3:Ce crystal, a 25×25×20 mm3 CeBr3 crystal and a 25×25×10 mm3 CeBr3 crystal. Each crystal was encapsulated and coupled to an array of 4×4 silicon photomultipliers through an optical window. The measurements were conducted using 81 keV and 356 keV gamma-rays from a collimated 133Ba source. The 3D position reconstruction of interaction points was performed using artificial neural networks trained with experimental data. Although the position resolution was significantly better for the thinner crystal, the 20 mm thick CeBr3 crystal showed an acceptable resolution of about 5.4 mm FWHM for the x and y coordinates, and 7.8 mm FWHM for the z-coordinate (crystal depth) at 356 keV. These values were obtained from the full position scans of the crystal sides. The position resolution of the LaBr3:Ce crystal was found to be considerably worse, presumably due to the highly diffusive optical interface between the crystal and the optical window of the enclosure. The energy resolution (FWHM) measured for 662 keV gamma-rays was 4.0% for LaBr3:Ce and 5.5% for CeBr3. The same crystals equipped with a PMT (Hamamatsu R6322-100) gave an energy resolution of 3.0% and 4.7%, respectively.
NASA Astrophysics Data System (ADS)
Wang, Yonggang; Xiao, Yong; Cheng, Xinyi; Li, Deng; Wang, Liwei
2016-02-01
For the continuous crystal-based positron emission tomography (PET) detector built in our lab, a maximum likelihood algorithm adapted for implementation on a field programmable gate array (FPGA) is proposed to estimate the three-dimensional (3D) coordinate of interaction position with the single-end detected scintillation light response. The row-sum and column-sum readout scheme organizes the 64 channels of photomultiplier (PMT) into eight row signals and eight column signals to be readout for X- and Y-coordinates estimation independently. By the reference events irradiated in a known oblique angle, the probability density function (PDF) for each depth-of-interaction (DOI) segment is generated, by which the reference events in perpendicular irradiation are assigned to DOI segments for generating the PDFs for X and Y estimation in each DOI layer. Evaluated by the experimental data, the algorithm achieves an average X resolution of 1.69 mm along the central X-axis, and DOI resolution of 3.70 mm over the whole thickness (0-10 mm) of crystal. The performance improvements from 2D estimation to the 3D algorithm are also presented. Benefiting from abundant resources of FPGA and a hierarchical storage arrangement, the whole algorithm can be implemented into a middle-scale FPGA. By a parallel structure in pipelines, the 3D position estimator on the FPGA can achieve a processing throughput of 15 M events/s, which is sufficient for the requirement of real-time PET imaging.
Undersea Laser Communications Field Test at the Naval Undersea Warfare Center (NUWC)
2016-08-30
and blue wavelength scenario suggests links in excess of 400 meters are achievable with small, low-power, narrow-beam lasercom terminals. The field...of 7.6 meters , which corresponded to between 8–12 beam extinction lengths. The PMT demonstration included real-time electronics to perform...communications link was demonstrated over 4.8 meters (5 beam extinction lengths) with an APD receiver. Communications and characterization data were
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wischnewski, R.; Andres, E.; Askebjer, P.
1999-08-23
The first stage of the AMANDA High Energy Neutrino Detectorat the South Pole, the 302 PMT array AMANDA-B with an expected effectivearea for TeV neutrinos of similar to 10(4) m(2), has been taking datasince 1997. Progress with calibration, investigation of ice properties,as well as muon and neutrino data analysis are described. The next stage20-string detector AMANDA-II with similar to 800 PMTs will be completedin spring 2000.
de Castilhos Ghisi, Nédia; Cestari, Marta Margarete
2013-04-01
The glyphosate-based herbicide, Roundup(®), is one of the most used pesticides worldwide. In concert with the advent of transgenic crops resistant to glyphosate, the use of this pesticide has led to an increase in agricultural yields. The objective of this study was to evaluate the genotoxic effect that the herbicide Roundup(®) (at a concentration of 6.67 μg/L, corresponding to 3.20 μg/L glyphosate) can have on the fish Corydoras paleatus. Treatment groups were exposed for 3, 6, and 9 days, and effects were analyzed using the piscine micronucleus test (PMT) and comet assay. A group subjected to filtered water only was used as a negative control. The PMT did not show differences between the control and exposed groups for any of the treatment times. In contrast, the comet assay showed a high rate of DNA damage in group exposed to Roundup(®) for all treatment times, both for blood and hepatic cells. We conclude that for the low concentration used in this research, the herbicide shows potential genotoxic effects. Future research will be important in evaluating the effects of this substance, whose presence in the environment is ever-increasing.
NASA Astrophysics Data System (ADS)
Haemisch, York; Frach, Thomas; Degenhardt, Carsten; Thon, Andreas
Silicon Photomultipliers (SiPMs) have emerged as promising alternative to fast vacuum photomultiplier tubes (PMT). A fully digital implementation of the Silicon Photomultiplier (dSiPM) has been developed in order to overcome the deficiencies and limitations of the so far only analog SiPMs (aSiPMs). Our sensor is based on arrays of single photon avalanche photodiodes (SPADs) integrated in a standard CMOS process. Photons are detected directly by sensing the voltage at the SPAD anode using a dedicated cell electronics block next to each diode. This block also contains active quenching and recharge circuits as well as a one bit memory for the selective inhibit of detector cells. A balanced trigger network is used to propagate the trigger signal from all cells to the integrated time-to-digital converter. In consequence, photons are detected and counted as digital signals, thus making the sensor less susceptible to temperature variations and electronic noise. The integration with CMOS logic provides the added benefit of low power consumption and possible integration of data post-processing directly in the sensor. In this overview paper, we discuss the sensor architecture together with its characteristics with a focus on scalability and practicability aspects for applications in medical imaging, high energy- and astrophysics.
Implementation of the next-generation Gas Cherenkov Detector at the National Ignition Facility
NASA Astrophysics Data System (ADS)
Carrera, J. A.; Herrmann, H. W.; Khater, H. Y.; Carpenter, A. C.; Beeman, B. V.; Hernandez, J. E.; Sitaraman, S.; Lopez, F. E.; Zylstra, A. B.; Griego, J. R.; Kim, Y. H.; Gales, S. A.; Horsfield, C. J.; Milnes, J. S.; Hares, J. D.
2017-08-01
The newest Gas Cherenkov Detector (GCD-3) diagnostic has completed its Phase I commissioning/milestone at the National Ignition Facility (NIF). GCD-3 was fielded for several years at the Omega Laser Facility in its initial configuration, before being moved to the NIF. Installation at the NIF involved optimization of GCD-3 for the higher background environment and designing a new insertion carrier assembly. GCD-3 serves as the initial phase towards the implementation of the "Super GCD" (SGCD) at the NIF. During this phase of development GCD-3 took measurements from a re-entrant well, 3.9 meters from target chamber center (TCC). Plans to insert GCD-3 within 20 cm of TCC with a Target and Diagnostic Manipulator (TANDM) will be discussed. Data was collected using a Photomultiplier Tube (PMT) in combination with a Mach-Zehnder based recording system. These measurements were used to aid in shielding analysis, validate MCNP models, and fuel design efforts for the SGCD. Findings from the initial data will be covered extensively, including an in-depth look into sources of background and possible mitigation strategies. Ongoing development of phase two, the addition of an ultra-high bandwidth Pulse Dilatation Photomultiplier Tube (PD-PMT), will also be presented.
NASA Astrophysics Data System (ADS)
Kissick, David J.; Muir, Ryan D.; Sullivan, Shane Z.; Oglesbee, Robert A.; Simpson, Garth J.
2013-02-01
Despite the ubiquitous use of multi-photon and confocal microscopy measurements in biology, the core techniques typically suffer from fundamental compromises between signal to noise (S/N) and linear dynamic range (LDR). In this study, direct synchronous digitization of voltage transients coupled with statistical analysis is shown to allow S/N approaching the theoretical maximum throughout an LDR spanning more than 8 decades, limited only by the dark counts of the detector on the low end and by the intrinsic nonlinearities of the photomultiplier tube (PMT) detector on the high end. Synchronous digitization of each voltage transient represents a fundamental departure from established methods in confocal/multi-photon imaging, which are currently based on either photon counting or signal averaging. High information-density data acquisition (up to 3.2 GB/s of raw data) enables the smooth transition between the two modalities on a pixel-by-pixel basis and the ultimate writing of much smaller files (few kB/s). Modeling of the PMT response allows extraction of key sensor parameters from the histogram of voltage peak-heights. Applications in second harmonic generation (SHG) microscopy are described demonstrating S/N approaching the shot-noise limit of the detector over large dynamic ranges.
Conover, Gloria M; Martinez-Morales, Fernando; Heidtman, Matthew I; Luo, Zhao-Qing; Tang, May; Chen, Cui; Geiger, Otto; Isberg, Ralph R
2008-02-01
The function of phosphatidylcholine (PC) in the bacterial cell envelope remains cryptic. We show here that productive interaction of the respiratory pathogen Legionella pneumophila with host cells requires bacterial PC. Synthesis of the lipid in L. pneumophila was shown to occur via either phospholipid N-methyltransferase (PmtA) or phosphatidylcholine synthase (PcsA), but the latter pathway was demonstrated to be of predominant importance. Loss of PC from the cell envelope caused lowered yields of L. pneumophila within macrophages as well as loss of high multiplicity cytotoxicity, while mutants defective in PC synthesis could be complemented either by reintroduction of PcsA or by overproduction of PmtA. The lowered yields and reduced cytotoxicity in mutants with defective PC biosynthesis were due to three related defects. First, there was a poorly functioning Dot/Icm apparatus, which delivers substrates required for intracellular growth into the cytosol of infected cells. Second, there was reduced bacterial binding to macrophages, possibly due to loss of PC or a PC derivative on the bacterium that is recognized by the host cell. Finally, strains lacking PC had low steady-state levels of flagellin protein, a deficit that had been previously associated with the phenotypes of lowered cytotoxicity and poor cellular adhesion.
NASA Astrophysics Data System (ADS)
Yelós, L. D.; Suarez, F.; García, B.
2017-10-01
Most recent discoveries in gamma ray astronomy with energies around 50 GeV to 30 TeV, were achieved with ground Cherenkov Telescopes, traditionally composed of a parabolic mirror and a single or an array of photo multiplier tubes (PMTs) in their focus. The same detectors (or similar) are used in most astrophysics experiments. Recently, a new detector, the silicon photo-multiplier (SiPM), is progressively replacing the PMTs due to their technical advantages. However some limitations in their functioning make them more complex to use than PMTs and forces their characterization for each project. This work describes the characterization of SiPM from SensL (model MicroFC-SMA-30035) and a PMT from Hamamatsu (model R1463), both detectors are possible options to be used in an array of three Cherenkov telescopes at CASLEO. Additionally, we include the results of the operation of both detectors under controlled laboratory conditions that simulate expected conditions at field. Laboratory test were run in a darkbox with a data acquisition system, a personalized data analyze system with ROOT libraries, temperature control and monitoring, polarization control, a controlled light source, and humidity monitoring.
Amaral, Ricardo Abrantes; Malbergier, André; Lima, Danielle Ruiz; Santos, Verena Castellani Vitor; Gorenstein, Clarice; Andrade, Arthur Guerra de
The aim of this study was to investigate whether cognitive variables proposed by the protection motivation theory (PMT) were predictive of occasional and frequent intention to drive after drinking in medical students. One hundred fifty-five students attending preclinical years at a Medical School in São Paulo, Brazil, participated in the study. They were asked about their last month substance use, history of drinking and driving, including driving after binge drinking, and risk perceptions based on a self-report questionnaire with statements about protection motivation, threat, and coping appraisals from the PMT model. Fifty-two students (33%) had previous experience of driving after drinking during the last year, and 54 students (35%) reported intention to drive after drinking within the next year. Regression analysis showed that higher scores in perception of personal vulnerability to risks were associated with occasional and frequent intention to continue pursuing this particular behavior. Poorer evaluations about short-term consequences of alcohol consumption and cognitions regarding external rewards were significantly associated with reported intention to continue driving after drinking. Considering the social and health impact of alcohol-impaired behaviors, our findings suggest the need of interventional efforts focused in increasing students' awareness about the negative consequences of drinking and driving aiming to enhance their motivation towards more adaptive behaviors.
Potato plants with genetically engineered tropane alkaloid precursors.
Küster, Nadine; Rosahl, Sabine; Dräger, Birgit
2017-02-01
Solanum tuberosum tropinone reductase I reduced tropinone in vivo. Suppression of tropinone reductase II strongly reduced calystegines in sprouts. Overexpression of putrescine N -methyltransferase did not alter calystegine accumulation. Calystegines are hydroxylated alkaloids formed by the tropane alkaloid pathway. They accumulate in potato (Solanum tuberosum L., Solanaceae) roots and sprouting tubers. Calystegines inhibit various glycosidases in vitro due to their sugar-mimic structure, but functions of calystegines in plants are not understood. Enzymes participating in or competing with calystegine biosynthesis, including putrescine N-methyltransferase (PMT) and tropinone reductases (TRI and TRII), were altered in their activity in potato plants by RNA interference (RNAi) and by overexpression. The genetically altered potato plants were investigated for the accumulation of calystegines and for intermediates of their biosynthesis. An increase in N-methylputrescine provided by DsPMT expression was not sufficient to increase calystegine accumulation. Overexpression and gene knockdown of StTRI proved that S. tuberosum TRI is a functional tropinone reductase in vivo, but no influence on calystegine accumulation was observed. When StTRII expression was suppressed by RNAi, calystegine formation was severely compromised in the transformed plants. Under phytochamber and green house conditions, the StTRII RNAi plants did not show phenotypic alterations. Further investigation of calystegines function in potato plants under natural conditions is enabled by the calystegine deprived StTRII RNAi plants.
NASA Astrophysics Data System (ADS)
Cherepy, Nerine J.; Payne, Stephen A.; Seeley, Zachary M.; Beck, Patrick R.; Swanberg, Erik L.; Hunter, Steven L.
2016-09-01
Breakthrough energy resolution, R(662keV) <4%, has been achieved with an oxide scintillator, Cerium-doped Gadolinium Yttrium Gallium Aluminum Garnet, or GYGAG(Ce), by optimizing fabrication conditions. Here we describe the dependence of scintillation light yield and energy resolution on several variables: (1) Stoichiometry, in particular Gd/Y and Ga/Al ratios which modify the bandgap energy, (2) Processing methods, including vacuum vs. oxygen sintering, and (3) Trace co-dopants that influence the formation of Ce4+ and modify the intra-bandgap trap distribution. To learn about how chemical composition influences the scintillation properties of transparent ceramic garnet scintillators, we have measured: scintillation decay component amplitudes; intensity and duration of afterglow; thermoluminescence glow curve peak positions and amplitudes; integrated light yield; light yield non-proportionality, as measured in the Scintillator Light Yield Non-Proportionality Characterization Instrument (SLYNCI); and energy resolution for gamma spectroscopy. Optimized GYGAG(Ce) provides R(662 keV) =3.0%, for 0.05 cm3 size ceramics with Silicon photodiode readout, and R(662 keV) =4.6%, at 2 in3 size with PMT readout.
NASA Astrophysics Data System (ADS)
Ammendola, R.; Biagioni, A.; Frezza, O.; Lo Cicero, F.; Martinelli, M.; Paolucci, P. S.; Pontisso, L.; Simula, F.; Vicini, P.; Ameli, F.; Nicolau, C. A.; Pastorelli, E.; Simeone, F.; Tosoratto, L.; Lonardo, A.
2016-04-01
The KM3NeT-Italia underwater neutrino detection unit, the tower, consists of 14 floors. Each floor supports 6 Optical Modules containing front-end electronics needed to digitize the PMT signal, format and transmit the data and 2 hydrophones that reconstruct in real-time the position of Optical Modules, for a maximum tower throughput of more than 600 MB/s. All floor data are collected by the Floor Control Module (FCM) board and transmitted by optical bidirectional virtual point-to-point connections to the on-shore laboratory, each FCM needing an on-shore counterpart as communication endpoint. In this contribution we present NaNet3, an on-shore readout board based on Altera Stratix V GX FPGA able to manage multiple FCM data channels with a capability of 800 Mbps each. The design is a NaNet customization for the KM3NeT-Italia experiment, adding support in its I/O interface for a synchronous link protocol with deterministic latency at physical level and for a Time Division Multiplexing protocol at data level.
A phoswich detector design for improved spatial sampling in PET
NASA Astrophysics Data System (ADS)
Thiessen, Jonathan D.; Koschan, Merry A.; Melcher, Charles L.; Meng, Fang; Schellenberg, Graham; Goertzen, Andrew L.
2018-02-01
Block detector designs, utilizing a pixelated scintillator array coupled to a photosensor array in a light-sharing design, are commonly used for positron emission tomography (PET) imaging applications. In practice, the spatial sampling of these designs is limited by the crystal pitch, which must be large enough for individual crystals to be resolved in the detector flood image. Replacing the conventional 2D scintillator array with an array of phoswich elements, each consisting of an optically coupled side-by-side scintillator pair, may improve spatial sampling in one direction of the array without requiring resolving smaller crystal elements. To test the feasibility of this design, a 4 × 4 phoswich array was constructed, with each phoswich element consisting of two optically coupled, 3 . 17 × 1 . 58 × 10mm3 LSO crystals co-doped with cerium and calcium. The amount of calcium doping was varied to create a 'fast' LSO crystal with decay time of 32.9 ns and a 'slow' LSO crystal with decay time of 41.2 ns. Using a Hamamatsu R8900U-00-C12 position-sensitive photomultiplier tube (PS-PMT) and a CAEN V1720 250 MS/s waveform digitizer, we were able to show effective discrimination of the fast and slow LSO crystals in the phoswich array. Although a side-by-side phoswich array is feasible, reflections at the crystal boundary due to a mismatch between the refractive index of the optical adhesive (n = 1 . 5) and LSO (n = 1 . 82) caused it to behave optically as an 8 × 4 array rather than a 4 × 4 array. Direct coupling of each phoswich element to individual photodetector elements may be necessary with the current phoswich array design. Alternatively, in order to implement this phoswich design with a conventional light sharing PET block detector, a high refractive index optical adhesive is necessary to closely match the refractive index of LSO.
DOI Determination by Rise Time Discrimination in Single-Ended Readout for TOF PET Imaging
Wiener, R.I.; Surti, S.; Karp, J.S.
2013-01-01
Clinical TOF PET systems achieve detection efficiency using thick crystals, typically of thickness 2–3cm. The resulting dispersion in interaction depths degrades spatial resolution for increasing radial positions due to parallax error. Furthermore, interaction depth dispersion results in time pickoff dispersion and thus in degraded timing resolution, and is therefore of added concern in TOF scanners. Using fast signal digitization, we characterize the timing performance, pulse shape and light output of LaBr3:Ce, CeBr3 and LYSO. Coincidence timing resolution is shown to degrade by ~50ps/cm for scintillator pixels of constant cross section and increasing length. By controlling irradiation depth in a scintillator pixel, we show that DOI-dependence of time pickoff is a significant factor in the loss of timing performance in thick detectors. Using the correlated DOI-dependence of time pickoff and charge collection, we apply a charge-based correction to the time pickoff, obtaining improved coincidence timing resolution of <200ps for a uniform 4×4×30mm3 LaBr3 pixel. In order to obtain both DOI identification and improved timing resolution, we design a two layer LaBr3[5%Ce]/LaBr3[30%Ce] detector of total size 4×4×30mm3, exploiting the dependence of scintillator rise time on [Ce] in LaBr3:Ce. Using signal rise time to determine interaction layer, excellent interaction layer discrimination is achieved, while maintaining coincidence timing resolution of <250ps and energy resolution <7% using a R4998 PMT. Excellent layer separation and timing performance is measured with several other commercially-available TOF photodetectors, demonstrating the practicality of this design. These results indicate the feasibility of rise time discrimination as a technique for measuring event DOI while maintaining sensitivity, timing and energy performance, in a well-known detector architecture. PMID:24403611
DOI Determination by Rise Time Discrimination in Single-Ended Readout for TOF PET Imaging.
Wiener, R I; Surti, S; Karp, J S
2013-06-01
Clinical TOF PET systems achieve detection efficiency using thick crystals, typically of thickness 2-3cm. The resulting dispersion in interaction depths degrades spatial resolution for increasing radial positions due to parallax error. Furthermore, interaction depth dispersion results in time pickoff dispersion and thus in degraded timing resolution, and is therefore of added concern in TOF scanners. Using fast signal digitization, we characterize the timing performance, pulse shape and light output of LaBr 3 :Ce, CeBr 3 and LYSO. Coincidence timing resolution is shown to degrade by ~50ps/cm for scintillator pixels of constant cross section and increasing length. By controlling irradiation depth in a scintillator pixel, we show that DOI-dependence of time pickoff is a significant factor in the loss of timing performance in thick detectors. Using the correlated DOI-dependence of time pickoff and charge collection, we apply a charge-based correction to the time pickoff, obtaining improved coincidence timing resolution of <200ps for a uniform 4×4×30mm 3 LaBr 3 pixel. In order to obtain both DOI identification and improved timing resolution, we design a two layer LaBr 3 [5%Ce]/LaBr 3 [30%Ce] detector of total size 4×4×30mm 3 , exploiting the dependence of scintillator rise time on [Ce] in LaBr 3 :Ce. Using signal rise time to determine interaction layer, excellent interaction layer discrimination is achieved, while maintaining coincidence timing resolution of <250ps and energy resolution <7% using a R4998 PMT. Excellent layer separation and timing performance is measured with several other commercially-available TOF photodetectors, demonstrating the practicality of this design. These results indicate the feasibility of rise time discrimination as a technique for measuring event DOI while maintaining sensitivity, timing and energy performance, in a well-known detector architecture.
Photodetector timing research at Fermilab
Ramberg, E.; Ronzhin, A.; Albrow, M.; ...
2011-01-01
We describe here the outlines of research undertaken by Fermilab into timing characteristics of photodetectors. We describe our experimental method and give benchtop results on the timing resolution of micro-channel plate photomultipliers (MCP-PMT) and silicon photomultipliers (SiPM). In addition, we describe results of various configurations of these detectors, along with quartz radiators, in particle test beams at Fermilab. Results for timing of scintillator light using the DRS4 high speed digitizer are also presented.
A Study of the Chinese Shipyard Management Control System.
1987-09-01
t9W.i-Pmt A SbiftBeck toRKesourcsDepmadimc-...... 7 .. 87 3I. O NCLUSION*** * ..........................******* *** * ....... 9 8 0 INTrIALD Slrr BUTION...Apgr..Innts *j... ..... o..*............... 4 7 " L INTRODUCTION A. TES OBJECTIVE The purpose of this rmach project is to study the management control...How do these people respond to radically chni pok d on and say productive? Apparently, they dont, In as volatile an inifronmejt as the Chinese
Batch production of microchannel plate photo-multipliers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frisch, Henry J.; Wetstein, Matthew; Elagin, Andrey
In-situ methods for the batch fabrication of flat-panel micro-channel plate (MCP) photomultiplier tube (PMT) detectors (MCP-PMTs), without transporting either the window or the detector assembly inside a vacuum vessel are provided. The method allows for the synthesis of a reflection-mode photocathode on the entrance to the pores of a first MCP or the synthesis of a transmission-mode photocathode on the vacuum side of a photodetector entrance window.
Knowledge-based nonuniform sampling in multidimensional NMR.
Schuyler, Adam D; Maciejewski, Mark W; Arthanari, Haribabu; Hoch, Jeffrey C
2011-07-01
The full resolution afforded by high-field magnets is rarely realized in the indirect dimensions of multidimensional NMR experiments because of the time cost of uniformly sampling to long evolution times. Emerging methods utilizing nonuniform sampling (NUS) enable high resolution along indirect dimensions by sampling long evolution times without sampling at every multiple of the Nyquist sampling interval. While the earliest NUS approaches matched the decay of sampling density to the decay of the signal envelope, recent approaches based on coupled evolution times attempt to optimize sampling by choosing projection angles that increase the likelihood of resolving closely-spaced resonances. These approaches employ knowledge about chemical shifts to predict optimal projection angles, whereas prior applications of tailored sampling employed only knowledge of the decay rate. In this work we adapt the matched filter approach as a general strategy for knowledge-based nonuniform sampling that can exploit prior knowledge about chemical shifts and is not restricted to sampling projections. Based on several measures of performance, we find that exponentially weighted random sampling (envelope matched sampling) performs better than shift-based sampling (beat matched sampling). While shift-based sampling can yield small advantages in sensitivity, the gains are generally outweighed by diminished robustness. Our observation that more robust sampling schemes are only slightly less sensitive than schemes highly optimized using prior knowledge about chemical shifts has broad implications for any multidimensional NMR study employing NUS. The results derived from simulated data are demonstrated with a sample application to PfPMT, the phosphoethanolamine methyltransferase of the human malaria parasite Plasmodium falciparum.
Oros, Carl L; Alves, Fabio
2018-01-01
Plants have evolved a variety of means to energetically sense and respond to abiotic and biotic environmental stress. Two typical photochemical signaling responses involve the emission of volatile organic compounds and light. The emission of certain leaf wound volatiles and light are mutually dependent upon oxygen which is subsequently required for the wound-induced lipoxygenase reactions that trigger the formation of fatty acids and hydroperoxides; ultimately leading to photon emission by chlorophyll molecules. A low noise photomultiplier with sensitivity in the visible spectrum (300-720 nm) is used to continuously measure long duration ultraweak photon emission of dark-adapting whole Spathiphyllum leaves (in vivo). Leaves were mechanically wounded after two hours of dark adaptation in aerobic and anaerobic conditions. It was found that (1) nitrogen incubation did not affect the pre-wound basal photocounts; (2) wound induced leaf biophoton emission was significantly suppressed when under anoxic stress; and (3) the aerobic wound induced emission spectra observed was > 650 nm, implicating chlorophyll as the likely emitter. Limitations of the PMT photocathode's radiant sensitivity, however, prevented accurate analysis from 700-720 nm. Further examination of leaf wounding profile photon counts revealed that the pre-wounding basal state (aerobic and anoxic), the anoxic wounding state, and the post-wounding aerobic state statistics all approximate a Poisson distribution. It is additionally observed that aerobic wounding induces two distinct exponential decay events. These observations contribute to the body of plant wound-induced luminescence research and provide a novel methodology to measure this phenomenon in vivo.
ZnO:Zn/6LiF scintillator-A low afterglow alternative to ZnS:Ag/6LiF for thermal neutron detection
NASA Astrophysics Data System (ADS)
Sykora, G. Jeff; Schooneveld, Erik M.; Rhodes, Nigel J.
2018-03-01
Current ZnS:Ag/6LiF based scintillation detectors are often count rate limited by the long lifetime afterglow in the scintillator. Despite this drawback, new instruments at neutron scattering facilities, like ISIS in the UK, would still like to use ZnS:Ag/6LiF detectors due to their low gamma sensitivity, high light output, simplicity of detector design and relatively inexpensive production. One particular advantage of ZnS:Ag/6LiF detectors is their ability to provide strong pulse shape discrimination between neutrons and gammas. Despite the advantages of these detectors, it is becoming clear that new and upgraded instruments will be limited by the count rate capability of ZnS:Ag/6LiF, so an alternative scintillator technology with equivalent simplicity is being sought. ZnO:Zn/6LiF is investigated here as a low afterglow alternative to ZnS:Ag/6LiF. Basic scintillation properties of ZnO:Zn are studied and are discussed. Pulse shape discrimination between neutrons and gammas is explored and taken advantage of through simple single photon counting methods. A further step toward a realistic detector for neutron scattering is also taken by fiber coupling the ZnO:Zn/6LiF to a PMT. In an initial study of this fiber coupled configuration, 60Co gamma sensitivity of ∼ 7 × 10-6 is shown and improvements in count rate capability of at least a factor of 6 over ZnS:Ag/6LiF based neutron detectors are demonstrated.
NASA Astrophysics Data System (ADS)
Chattopadhyay, T.; Vadawale, S. V.; Goyal, S. K.; Mithun, N. P. S.; Patel, A. R.; Shukla, R.; Ladiya, T.; Shanmugam, M.; Patel, V. R.; Ubale, G. P.
2016-02-01
X-ray polarization measurement of cosmic sources provides two unique parameters namely degree and angle of polarization which can probe the emission mechanism and geometry at close vicinity of the compact objects. Specifically, the hard X-ray polarimetry is more rewarding because the sources are expected to be intrinsically highly polarized at higher energies. With the successful implementation of Hard X-ray optics in NuSTAR, it is now feasible to conceive Compton polarimeters as focal plane detectors. Such a configuration is likely to provide sensitive polarization measurements in hard X-rays with a broad energy band. We are developing a focal plane hard X-ray Compton polarimeter consisting of a plastic scintillator as active scatterer surrounded by a cylindrical array of CsI(Tl) scintillators. The scatterer is 5 mm diameter and 100 mm long plastic scintillator (BC404) viewed by normal PMT. The photons scattered by the plastic scatterer are collected by a cylindrical array of 16 CsI(Tl) scintillators (5 mm × 5 mm × 150 mm) which are read by Si Photomultiplier (SiPM). Use of the new generation SiPMs ensures the compactness of the instrument which is essential for the design of focal plane detectors. The expected sensitivity of such polarimetric configuration and complete characterization of the plastic scatterer, specially at lower energies have been discussed in [11, 13]. In this paper, we characterize the CsI(Tl) absorbers coupled to SiPM. We also present the experimental results from the fully assembled configuration of the Compton polarimeter.
Valoppi, Laura
2018-04-02
Executive SummaryThe South Bay Salt Pond Restoration Project (Project) is one of the largest restoration efforts in the United States. It is located in South San Francisco Bay of California. It is unique not only for its size—more than 15,000 acres—but also for its location adjacent to one of the nation’s largest urban areas, home to more than 4 million people (Alameda, Santa Clara, and San Mateo Counties). The Project is intended to restore and enhance wetlands in South San Francisco Bay while providing for flood management, wildlife-oriented public access, and recreation. Restoration goals of the project are to provide a mosaic of saltmarsh habitat to benefit marsh species and managed ponds to benefit waterbirds, throughout 3 complexes and 54 former salt ponds.Although much is known about the project area, significant uncertainties remain with a project of this geographic and temporal scale of an estimated 50 years to complete the restoration. For example, in order to convert anywhere from 50 to 90 percent of the existing managed ponds to saltmarsh habitat, conservation managers first enhance the habitat of managed ponds in order to increase use by waterbirds, and provide migratory, wintering, and nesting habitat for more than 90 species of waterbirds. Project managers have concluded that the best way to address these uncertainties is to carefully implement the project in phases and learn from the outcome of each phase. The Adaptive Management Plan (AMP) identifies specific restoration targets for multiple aspects of the Project and defines triggers that would necessitate some type of management action if a particular aspect is trending negatively. U.S. Geological Survey (USGS) biologist Laura Valoppi served as the project Lead Scientist and oversaw implementation of the AMP in coordination with other members of the Project Management Team (PMT), comprised of representatives from the California State Coastal Conservancy, California Department of Fish and Wildlife, the Santa Clara Valley Water District, the U.S. Army Corps of Engineers, and the U.S. Fish and Wildlife Service.To implement the AMP, the PMT have selected and funded applied studies and monitoring projects to address key uncertainties. This information is used by the PMT to make decisions about current management of the project area and future restoration actions in order to meet project.This document summarizes the major scientific findings from studies conducted from 2009 to 2016, as part of the science program that was conducted in conjunction with Phase 1 restoration and management actions. Additionally, this report summarizes the management response to the study results under the guidance of the AMP framework and provides a list of suggested studies to be conducted in “Phase 2–A scorecard summarizing the Project’s progress toward meeting the AMP goals for a range of Project objectives.” The scoring to date indicates that the Project is meeting or exceeding expectations for sediment accretion and western snowy plover (Charadrius alexandrinus nivosus) recovery. There is uncertainty with respect to objectives for California gulls (Larus californicus), California least tern (Sternula antillarum), steelhead trout (Oncorhynchus mykiss), and regulatory water quality objectives. Water quality and algal blooms, specifically of the managed ponds, is indicated as trending negative. However, the vast majority of objectives are trending positive, including increased abundance for a number of bird guilds, increasing marsh habitat, maintenance of mudflats, visitor experience, estuarine fish numbers, and special-status marsh species numbers.
The water Cherenkov detectors of the HAWC Observatory
NASA Astrophysics Data System (ADS)
Longo, Megan; Mostafa, Miguel
2012-10-01
The High Altitude Water Cherenkov (HAWC) observatory is a very high-energy gamma-ray detector which is currently under construction at 4100 m in Sierra Negra, Mexico. The observatory will be composed of an array of 300 Water Cherenkov Detectors (WCDs). Each WCD consists of a 5 m tall by 7.3 m wide steel tank containing a hermetically sealed plastic bag, called a bladder, which is filled with 200,000 liters of purified water. The detectors are each equipped with four upward-facing photomultiplier tubes (PMTs), anchored to the bottom of the bladder. At Colorado State University (CSU) we have the only full-size prototype outside of the HAWC site. It serves as a testbed for installation and operation procedures for the HAWC observatory. The WCD at CSU has been fully operational since March 2011, and has several components not yet present at the HAWC site. In addition to the four HAWC position PMTs, our prototype has three additional PMTs, including one shrouded (dark) PMT. We also have five scintillator paddles, four buried underneath the HAWC position PMTs, and one freely moving paddle above the volume of water. These extra additions will allow us to work on muon reconstruction with a single WCD. We will describe the analysis being done with the data taken with the CSU prototype, its impact on the HAWC detector, and future plans for the prototype.
Berg, Eric; Roncali, Emilie; Kapusta, Maciej; Du, Junwei; Cherry, Simon R
2016-02-01
In support of a project to build a total-body PET scanner with an axial field-of-view of 2 m, the authors are developing simple, cost-effective block detectors with combined time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. This work focuses on investigating the potential of phosphor-coated crystals with conventional PMT-based block detector readout to provide DOI information while preserving timing resolution. The authors explored a variety of phosphor-coating configurations with single crystals and crystal arrays. Several pulse shape discrimination techniques were investigated, including decay time, delayed charge integration (DCI), and average signal shapes. Pulse shape discrimination based on DCI provided the lowest DOI positioning error: 2 mm DOI positioning error was obtained with single phosphor-coated crystals while 3-3.5 mm DOI error was measured with the block detector module. Minimal timing resolution degradation was observed with single phosphor-coated crystals compared to uncoated crystals, and a timing resolution of 442 ps was obtained with phosphor-coated crystals in the block detector compared to 404 ps without phosphor coating. Flood maps showed a slight degradation in crystal resolvability with phosphor-coated crystals; however, all crystals could be resolved. Energy resolution was degraded by 3%-7% with phosphor-coated crystals compared to uncoated crystals. These results demonstrate the feasibility of obtaining TOF-DOI capabilities with simple block detector readout using phosphor-coated crystals.
Software Tools Streamline Project Management
NASA Technical Reports Server (NTRS)
2009-01-01
Three innovative software inventions from Ames Research Center (NETMARK, Program Management Tool, and Query-Based Document Management) are finding their way into NASA missions as well as industry applications. The first, NETMARK, is a program that enables integrated searching of data stored in a variety of databases and documents, meaning that users no longer have to look in several places for related information. NETMARK allows users to search and query information across all of these sources in one step. This cross-cutting capability in information analysis has exponentially reduced the amount of time needed to mine data from days or weeks to mere seconds. NETMARK has been used widely throughout NASA, enabling this automatic integration of information across many documents and databases. NASA projects that use NETMARK include the internal reporting system and project performance dashboard, Erasmus, NASA s enterprise management tool, which enhances organizational collaboration and information sharing through document routing and review; the Integrated Financial Management Program; International Space Station Knowledge Management; Mishap and Anomaly Information Reporting System; and management of the Mars Exploration Rovers. Approximately $1 billion worth of NASA s projects are currently managed using Program Management Tool (PMT), which is based on NETMARK. PMT is a comprehensive, Web-enabled application tool used to assist program and project managers within NASA enterprises in monitoring, disseminating, and tracking the progress of program and project milestones and other relevant resources. The PMT consists of an integrated knowledge repository built upon advanced enterprise-wide database integration techniques and the latest Web-enabled technologies. The current system is in a pilot operational mode allowing users to automatically manage, track, define, update, and view customizable milestone objectives and goals. The third software invention, Query-Based Document Management (QBDM) is a tool that enables content or context searches, either simple or hierarchical, across a variety of databases. The system enables users to specify notification subscriptions where they associate "contexts of interest" and "events of interest" to one or more documents or collection(s) of documents. Based on these subscriptions, users receive notification when the events of interest occur within the contexts of interest for associated document or collection(s) of documents. Users can also associate at least one notification time as part of the notification subscription, with at least one option for the time period of notifications.
Simulator study of young driver's instinctive response of lower extremity to a collision.
Gao, Zhenhai; Li, Chuzhao; Hu, Hongyu; Zhao, Hui; Chen, Chaoyang; Yu, Huili
2016-05-18
A driver's instinctive response of the lower extremity in braking movement consists of two parts, including reaction time and braking reaction behavior. It is critical to consider these two components when conducting studies concerning driver's brake movement intention and injury analysis. The purposes of this study were to investigate the driver reaction time to an oncoming collision and muscle activation of lower extremity muscles at the collision moment. The ultimate goal is to provide data that aid in both the optimization of intervention time of an active safety system and the improvement of precise protection performance of a passive safety system. A simulated collision scene was constructed in a driving simulator, and 40 young volunteers (20 male and 20 female) were recruited for tests. Vehicle control parameters and electromyography characteristics of eight muscles of the lower extremity were recorded. The driver reaction time was divided into pre-motor time (PMT) and muscle activation time (MAT). Muscle activation level (ACOL) at the collision moment was calculated and analysed. PMT was shortest for the tibialis anterior (TA) muscle (243∼317 ms for male and 278∼438 ms for female). Average MAT of the TA ranged from 28-55 ms. ACOL was large (5∼31% for male and 5∼23% for female) at 50 km/h, but small (<12%) at 100 km/h. ACOL of the gluteus maximus was smallest (<3%) in the 25 and 100 km/h tests. ACOL of RF of men was significantly smaller than that of women at different speeds. Ankle dorsiflexion is firstly activated at the beginning of the emergency brake motion. Males showed stronger reaction ability than females, as suggested by male's shorter PMT. The detection of driver's brake intention is upwards of 55ms sooner after introducing the electromyography. Muscle activation of the lower extremity is an important factor for 50 km/h collision injury analysis. For higher speed collisions, this might not be a major factor. The activations of certain muscles may be ignored for crash injury analysis at certain speeds, such as gluteus maximus at 25 or 100 km/h. Furthermore, the activation of certain muscles should be differentiated between males and females during injury analysis.
NASA Astrophysics Data System (ADS)
Van Elburg, Devin J.; Noble, Scott D.; Hagey, Simone; Goertzen, Andrew L.
2018-03-01
Optical coupling is an important factor in detector design as it improves optical photon transmission by mitigating internal reflections at light-sharing boundaries. In this work we compare optical coupling materials, namely double-sided acrylic polymer tapes and silicone optical grease (SiG), in the context of positron emission tomography. Four double-sided tapes from 3 M of varying thicknesses (0.229 mm-1.016 mm) and adhesive materials (‘100MP’, ‘A100’, and ‘GPA’) were characterized with spectrophotometer measurements as well as photopeak amplitude and energy resolution measurements using lutetium-yttrium oxy-orthosilicate (LYSO) coupled to photomultiplier tubes (PMT) or silicon photomultipliers (SiPMs). Transmission spectra from the spectrophotometer showed over 80% transmission for all tapes at 420 nm and above, with 89.6% and 88.8% transmission for the 0.508 mm and 1.016 mm thick GPA tapes, respectively, at 420 nm. Measurements with single-pixel LYSO-PMT and 4 × 4 array (one-to-one coupled) LYSO-SiPM setups determined that SiG had the greatest photopeak amplitude, with tapes showing 2.1%-14.8% reduction in photopeak amplitude with respect to SiG. Energy resolution changed by less than 4% on a relative basis between tapes and SiG with PMT measurements, however for the SiPM array measurements the energy resolution improved from 15.6% ± 2.7% full-width at half-maximum to 11.4% ± 1.2% for SiG and 1 mm GPA respectively. Data acquired with dual-layer offset LYSO arrays (light sharing detector designs) demonstrated that a detector coupled with 1 mm thick GPA tape produced equivalent detector flood histograms to those from a design coupled with SiG and a 1 mm thick glass lightguide. No significant degradation in photopeak amplitude and energy resolution was observed over five months of measurements, indicating the tapes maintain their coupling integrity over several months. Though minimal photopeak amplitude degradation compared to SiG occurs, double-sided tapes are convenient alternatives for optical coupling materials since they diffuse light intrinsically, acting as a light guide, offer mechanical support and durability, are easily applied and removed from scintillators/photodetectors, and are relatively inexpensive and readily available.
Van Elburg, Devin J; Noble, Scott D; Hagey, Simone; Goertzen, Andrew L
2018-02-26
Optical coupling is an important factor in detector design as it improves optical photon transmission by mitigating internal reflections at light-sharing boundaries. In this work we compare optical coupling materials, namely double-sided acrylic polymer tapes and silicone optical grease (SiG), in the context of positron emission tomography. Four double-sided tapes from 3 M of varying thicknesses (0.229 mm-1.016 mm) and adhesive materials ('100MP', 'A100', and 'GPA') were characterized with spectrophotometer measurements as well as photopeak amplitude and energy resolution measurements using lutetium-yttrium oxy-orthosilicate (LYSO) coupled to photomultiplier tubes (PMT) or silicon photomultipliers (SiPMs). Transmission spectra from the spectrophotometer showed over 80% transmission for all tapes at 420 nm and above, with 89.6% and 88.8% transmission for the 0.508 mm and 1.016 mm thick GPA tapes, respectively, at 420 nm. Measurements with single-pixel LYSO-PMT and 4 × 4 array (one-to-one coupled) LYSO-SiPM setups determined that SiG had the greatest photopeak amplitude, with tapes showing 2.1%-14.8% reduction in photopeak amplitude with respect to SiG. Energy resolution changed by less than 4% on a relative basis between tapes and SiG with PMT measurements, however for the SiPM array measurements the energy resolution improved from 15.6% ± 2.7% full-width at half-maximum to 11.4% ± 1.2% for SiG and 1 mm GPA respectively. Data acquired with dual-layer offset LYSO arrays (light sharing detector designs) demonstrated that a detector coupled with 1 mm thick GPA tape produced equivalent detector flood histograms to those from a design coupled with SiG and a 1 mm thick glass lightguide. No significant degradation in photopeak amplitude and energy resolution was observed over five months of measurements, indicating the tapes maintain their coupling integrity over several months. Though minimal photopeak amplitude degradation compared to SiG occurs, double-sided tapes are convenient alternatives for optical coupling materials since they diffuse light intrinsically, acting as a light guide, offer mechanical support and durability, are easily applied and removed from scintillators/photodetectors, and are relatively inexpensive and readily available.
A Model of Mantle Plume Based on Hawaiian Magmatism
NASA Astrophysics Data System (ADS)
Takahashi, E.
2001-12-01
In order to constrain the chemistry and temperature of the hot rising material (mantle plume), we have studied growth history of Koolau volcano in Hawaii based on reconstruction of giant submarine landslides (Evolution of Hawaiian Volcanoes, AGU Monograph, 2001). Based on petrology of the Koolau lava and high-pressure melting experiments, we propose a model that the Hawaiian plume has a potential mantle temperature (PMT) of only 1400C and the primitive magma at the final growth stage of Koolau volcano (Makapuu stage) was formed by extensive melting of a large block of recycled old oceanic crust (eclogite block of 1000km3 in volume). Our PMT is much lower than the estimate for the modern Hawaiian plume by Watson and McKenzie (1991, PMT=1558C) assuming homogeneous peridotite source. Melting experiments of basalt/peridotite hybrid source at 3 GPa (Takahashi and Nakajima, 2001) show that only slight temperature increase (less than 50deg) will shift the Koolau type primary melts (SiO2=53, MgO=7 wt.%) to the parental Mauna Loa and Kilauea type melts (SiO2=49, MgO=14). Geometry of the partial melt zone surrounding upwelling eclogite blocks may cause the inter-shield chemical variation among the Hawaiian volcanoes. The lower plume temperature and the existence of large blocks of former oceanic crust in the plume require reconsideration on the origin of the mantle plume and the mechanism of its upwelling transport. Presence or absence of the old oceanic crust in the plume will explain chemical diversity and the contrasting melt productivity between hot spots (e.g., Iceland vs. Azores). The large low velocity anomaly down to the CMB underneath the South Pacific hot spots (most distinct in global tomography), presently yields smaller magma flux than a single Hawaiian hot spot. The South Pacific plume may consist of upwelling warm hurzburgite (depleted ancient oceanic lithosphere). The South Pacific hot spot however was very magma productive in the Cretaceous time when large amount of recycled oceanic crust was entrained in the same plume. High-pressure experiments on density of subducted oceanic crust suggest that much of the subducted eclogite is stored above the 660km discontinuity. The fluctuation in magmatism in given hot spots may be explained by the interaction of the eclogite stock layer and the ascending plume.
NASA Astrophysics Data System (ADS)
Johnson, W.; Repasky, K. S.; Nehrir, A. R.; Carlsten, J.
2011-12-01
A differential absorption lidar (DIAL) for monitoring carbon dioxide (CO2) is under development at Montana State University using commercially available parts. Two distributed feedback (DFB) lasers, one at the on-line wavelength and one at the off-line wavelength are used to injection seed a fiber amplifier. The DIAL operates in the 1.57 micron carbon dioxide absorption band at an on-line wavelength of 1.5714060 microns. The laser transmitter produces 40 μJ pulses with a pulse duration of 1 μs and a pulse repetition frequency of 20 kHz. The scattered light from the laser transmitter is collected using a 28 cm diameter Schmidt-Cassegrain telescope. The light collected by the telescope is collimated and then filtered using a 0.8 nm FWHM narrowband interference filter. After the optical filter, the light is coupled into a multimode optical fiber with a 1000 μm core diameter. The output from the optical fiber is coupled into a photomultiplier tube (PMT) used to monitor the return signal. The analog output from the PMT is next incident on a discriminator producing TTL logic pulses for photon counting. The output from the PMT and discriminator is monitored using a multichannel scalar card allowing the counting of the TTL pulses as a function of range. Data from the DIAL instrument is collected in the following manner. The fiber amplifier is injection seeded first with the on-line DFB laser. The return signal as a function of range is integrated using the multichannel scalar for a user defined time, typically set at 6 s. The off-line DFB laser is then used to injection seed the fiber amplifier and the process is repeated. This process is repeated for a user defined period. The CO2 concentration as a function of range is calculated using the on-line and off-line return signals with the DIAL equation. A comparison of the CO2 concentration measured using the DIAL instrument at 1.5 km and a Li-Cor LI-820 in situ sensor located at 1.5 km from the DIAL over a 2.5 hour period indicate that the CO2 DIAL has an accuracy of ±20 parts per million (PPM).
2015-08-01
lifetime ( t2 ) corresponds to protein- bound NADH (23). Conversely, protein-bound FAD corre- sponds to the short lifetime, whereas free FAD corresponds...single photon counting (TCSPC) electronics (SPC-150, Becker and Hickl). TCSPC uses a fast detector PMT to measure the time between a laser pulse and... Becker and Hickl). A binning of nine surrounding pixels was used. Then, the fluorescence lifetime components were computed for each pixel by deconvolving
2009-12-01
Balanced Scorecard CAPM Capital Asset Pricing Model DIS Defense Information System DoD Department of...Measurement Tool (PMT) is the Balanced Scorecard (BSC) based on critical success factors and key performance indicators. The MND has referred to Jung’s...authors can replicate the methodology for multiple projects to generate a portfolio of projects. Similar to the Capital Asset Pricing Model ( CAPM ) or
Jehu-Appiah, Caroline; Aryeetey, Genevieve; Spaan, Ernst; Agyepong, Irene; Baltussen, Rob
2010-05-01
This paper outlines the potential strategies to identify the poor, and assesses their feasibility, efficiency and equity. Analyses are illustrated for the case of premium exemptions under National Health Insurance (NHI) in Ghana. A literature search in Medline search was performed to identify strategies to identify the poor. Models were developed including information on demography and poverty, and costs and errors of in- and exclusion of these strategies in two regions in Ghana. Proxy means testing (PMT), participatory welfare ranking (PWR), and geographic targeting (GT) are potentially useful strategies to identify the poor, and vary in terms of their efficiency, equity and feasibility. Costs to exempt one poor individual range between US$11.63 and US$66.67, and strategies may exclude up to 25% of the poor. Feasibility of strategies is dependent on their aptness in rural/urban settings, and administrative capacity to implement. A decision framework summarizes the above information to guide policy making. We recommend PMT as an optimal strategy in relative low poverty incidence urbanized settings, PWR as an optimal strategy in relative low poverty incidence rural settings, and GT as an optimal strategy in high incidence poverty settings. This paper holds important lessons not only for NHI in Ghana but also for other countries implementing exemption policies. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.
Aryeetey, Genevieve Cecilia; Jehu-Appiah, Caroline; Spaan, Ernst; Agyepong, Irene; Baltussen, Rob
2012-01-01
To analyse the costs and evaluate the equity, efficiency and feasibility of four strategies to identify poor households for premium exemptions in Ghana's National Health Insurance Scheme (NHIS): means testing (MT), proxy means testing (PMT), participatory wealth ranking (PWR) and geographic targeting (GT) in urban, rural and semi-urban settings in Ghana. We conducted the study in 145-147 households per setting with MT as our gold standard strategy. We estimated total costs that included costs of household surveys and cost of premiums paid to the poor, efficiency (cost per poor person identified), equity (number of true poor excluded) and the administrative feasibility of implementation. The cost of exempting one poor individual ranged from US$15.87 to US$95.44; exclusion of the poor ranged between 0% and 73%. MT was most efficient and equitable in rural and urban settings with low-poverty incidence; GT was efficient and equitable in the semi-urban setting with high-poverty incidence. PMT and PWR were less equitable and inefficient although feasible in some settings. We recommend MT as optimal strategy in low-poverty urban and rural settings and GT as optimal strategy in high-poverty semi-urban setting. The study is relevant to other social and developmental programmes that require identification and exemptions of the poor in low-income countries. © 2011 Blackwell Publishing Ltd.
Ellis, Richard; Hing, Wayne; Dilley, Andrew; McNair, Peter
2008-08-01
Diagnostic ultrasound provides a technique whereby real-time, in vivo analysis of peripheral nerve movement is possible. This study measured sciatic nerve movement during a "slider" neural mobilisation technique (ankle dorsiflexion/plantar flexion and cervical extension/flexion). Transverse and longitudinal movement was assessed from still ultrasound images and video sequences by using frame-by-frame cross-correlation software. Sciatic nerve movement was recorded in the transverse and longitudinal planes. For transverse movement, at the posterior midthigh (PMT) the mean value of lateral sciatic nerve movement was 3.54 mm (standard error of measurement [SEM] +/- 1.18 mm) compared with anterior-posterior/vertical (AP) movement of 1.61 mm (SEM +/- 0.78 mm). At the popliteal crease (PC) scanning location, lateral movement was 6.62 mm (SEM +/- 1.10 mm) compared with AP movement of 3.26 mm (SEM +/- 0.99 mm). Mean longitudinal sciatic nerve movement at the PMT was 3.47 mm (SEM +/- 0.79 mm; n = 27) compared with the PC of 5.22 mm (SEM +/- 0.05 mm; n = 3). The reliability of ultrasound measurement of transverse sciatic nerve movement was fair to excellent (Intraclass correlation coefficient [ICC] = 0.39-0.76) compared with excellent (ICC = 0.75) for analysis of longitudinal movement. Diagnostic ultrasound presents a reliable, noninvasive, real-time, in vivo method for analysis of sciatic nerve movement.
NASA Astrophysics Data System (ADS)
Kassamakov, Ivan; Maconi, Göran; Penttilä, Antti; Helander, Petteri; Gritsevich, Maria; Puranen, Tuomas; Salmi, Ari; Hæggström, Edward; Muinonen, Karri
2018-02-01
We present the design of a novel scatterometer for precise measurement of the angular Mueller matrix profile of a mm- to µm-sized sample held in place by sound. The scatterometer comprises a tunable multimode Argon-krypton laser (with possibility to set 1 of the 12 wavelengths in visible range), linear polarizers, a reference photomultiplier tube (PMT) for monitoring the beam intensity, and a micro-PMT module mounted radially towards the sample at an adjustable radius. The measurement angle is controlled by a motor-driven rotation stage with an accuracy of 15'. The system is fully automated using LabVIEW, including the FPGA-based data acquisition and the instrument's user interface. The calibration protocol ensures accurate measurements by using a control sphere sample (diameter 3 mm, refractive index of 1.5) fixed first on a static holder followed by accurate multi-wavelength measurements of the same sample levitated ultrasonically. To demonstrate performance of the scatterometer, we conducted detailed measurements of light scattered by a particle derived from the Chelyabinsk meteorite, as well as planetary analogue materials. The measurements are the first of this kind, since they are obtained using controlled spectral angular scattering including linear polarization effects, for arbitrary shaped objects. Thus, our novel approach permits a non-destructive, disturbance-free measurement with control of the orientation and location of the scattering object.
Measurement of LYSO Intrinsic Light Yield Using Electron Excitation
NASA Astrophysics Data System (ADS)
Turtos, Rosana Martinez; Gundacker, Stefan; Pizzichemi, Marco; Ghezzi, Alessio; Pauwels, Kristof; Auffray, Etiennette; Lecoq, Paul; Paganoni, Marco
2016-04-01
The determination of the intrinsic light yield (LYint) of scintillating crystals, i.e. number of optical photons created per amount of energy deposited, constitutes a key factor in order to characterize and optimize their energy and time resolution. However, until now measurements of this quantity are affected by large uncertainties and often rely on corrections for bulk absorption and surface/edge state. The novel idea presented in this contribution is based on the confinement of the scintillation emission in the central upper part of a 10 mm cubic crystal using a 1.5 MeV electron beam with diameter of 1 mm. A black non-reflective pinhole aligned with the excitation point is used to fix the light extraction solid angle (narrower than total reflection angle), which then sets a light cone travel path through the crystal. The final number of photoelectrons detected using a Hamamatsu R2059 photomultiplier tube (PMT) was corrected for the extraction solid angle, the Fresnel reflection coefficient and quantum efficiency (QE) of the PMT. The total number of optical photons produced per energy deposited was found to be 40000 ph/MeV ± 9% (syst) ±3% (stat) for LYSO. Simulations using Geant4 were successfully compared to light output measurements of 2 × 2 mm2 section crystals with lengths of 5-30 mm, in order to validate the light transport model and set a limit on Light Transfer Efficiency estimations.
Ion flow measurements during the rotating kink behavior of the central column in the HIST device
NASA Astrophysics Data System (ADS)
Yamada, S.; Yoshikawa, T.; Hashimoto, S.; Nishioka, T.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.
2007-11-01
Plasma flow is essentially driven in self-organization and magnetic reconnection process of compact spherical torus (ST) and spheromak in the helicity-driven systems. For example, when reversing the external toroidal field of ST, the direction not only of the plasma current but also of the toroidal ion flow is self-reversed during the formation of the flipped ST relaxed states. Mach probe measurement shows that the velocity of the ion flow reversed after the flip increases to about 20 km/s. We have been newly developing an ion Doppler spectrometer (IDS) system using a compact 16 or 64 channel photomultiplier tube (PMT) in order to measure the spatial profile of ion temperature and rotation velocity in the HIST device. The IDS system consists of a light collection system including optical fibers, 1 m-spectrometer and the PMT detector. The optical fibers covered with glass tubes are inserted into the plasma. The glass tubes can be rotated in the poloidal and the toroidal directions. The new IDS system will be applied to observations of ion temperature and plasma rotation in the flipped ST formation and in the MHD control of kinking behaviors of the central column by using the rotating magnetic field (RMF). Preliminary IDS results will be compared to those from Mach probe measurements in space.
Ion flow measurements during the MHD relaxation processes in the HIST spherical torus device
NASA Astrophysics Data System (ADS)
Nishioka, T.; Hashimoto, S.; Ando, K.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.
2008-11-01
Plasma flow is one of the key roles in self-organization and magnetic reconnection processes of helicity-driven spherical torus (ST) and spheromak. The HIST spherical torus can form the standard ST and the flipped ST plasmas by utilizing the variation of the external toroidal field coil current. The flipped ST plasma can be generated by changing the polarity of the toroidal magnetic field during the standard ST discharge [1]. We have developed an ion Doppler spectrometer (IDS) system using a compact 16 channel photomultiplier tube (PMT) in order to measure the spatial profile of ion temperature and rotation velocity in the HIST device. The IDS system consists of a light collection system including optical fibers, 1 m-spectrometer and the PMT detector. As the results, it was observed that ion velocity was about 10 km/s in the same direction as the toroidal current and ExB direction in the standard ST discharge. The observed ion velocity agrees with Mach probe measurements. During the transition from the standard ST to the flipped ST state, the ion temperature was fluctuated and increased. The result implies an ion heating during magnetic reconnections. In addition, the toroidal direction of the ion flow was reversed. The detail physics of the observed phenomenon will be shown. [1] M. Nagata et al., Phys Rev. Lett. 90, pp. 225001-225004 (2003).
Ultra-violet avalanche photodiode based on AlN/GaN periodically-stacked-structure
NASA Astrophysics Data System (ADS)
Wu, Xingzhao; Zheng, Jiyuan; Wang, Lai; Brault, Julien; Matta, Samuel; Hao, Zhibiao; Sun, Changzheng; Xiong, Bing; Luo, Yi; Han, Yianjun; Wang, Jian; Li, Hongtao; Khalfioui, Mohamed A.; Li, Mo; Kang, Jianbin; Li, Qian
2018-02-01
The high-gain photomultiplier tube (PMT) is the most popular method to detect weak ultra-violet signals which attenuate quickly in atmosphere, although the vacuum tube makes it fragile and difficult to integrate. To overcome the disadvantage of PMT, an AlN/GaN periodically-stacked-structure (PSS) avalanche photodiode (APD) has been proposed, finally achieving good quality of high gain and low excessive noise. As there is a deep g valley only in the conduction band of both GaN and AlN, the electron transfers suffering less scattering and thus becomes easier to obtain the threshold of ionization impact. Because of unipolar ionization in the PSS APD, it works in linear mode. Four prototype devices of 5-period, 10-period, 15-period, and 20-period were fabricated to verify that the gain of APD increases exponentially with period number. And in 20-period device, a recorded high and stable gain of 104 was achieved under constant bias. In addition, it is proved both experimentally and theoretically, that temperature stability on gain is significantly improved in PSS APD. And it is found that the resonant enhancement in interfacial ionization may bring significant enhancement of electron ionization performance. To make further progress in PSS APD, the device structure is investigated by simulation. Both the gain and temperature stability are optimized alternatively by a proper design of periodical thickness and AlN layer occupancy.
Evaluation of novel PMTs of worldwide best parameters for the CTA project
NASA Astrophysics Data System (ADS)
Mirzoyan, R.; Müller, D.; Hose, J.; Menzel, U.; Nakajima, D.; Takahashi, M.; Teshima, M.; Toyama, T.; Yamamoto, T.
2017-02-01
Photomultiplier Tubes (PMT) are the most widespread detectors for measuring fast and faint light signals. About six years ago, we started an improvement program for the PMT candidates for the Cherenkov Telescope Array (CTA) project in cooperation with the companies Hamamatsu Photonics K.K. (Japan) and Electron Tubes Enterprises Ltd. (England). CTA is the next major Imaging Atmospheric Cherenkov Telescopes array for ground-based high energy gamma-ray astrophysics. A total of ∼ 100 telescopes of sizes of 23 m, 12 m and 4 m in diameter will be built in northern and southern hemispheres. For CTA we need PMTs with the highest quantum efficiency and photoelectron collection efficiency, short pulse width of a few ns, low transit time spread and very low afterpulsing. The manufacturers were able to produce 1.5‧ PMTs of enhanced peak quantum efficiency of ∼ 40 % . These collect up to 95-98% of photoelectrons onto the first dynode for the wavelengths ≥ 400 nm . A pulse width of ≤ 3 ns has been achieved at the selected operational gain of 40k. The afterpulsing for a threshold of ≥ 4 photoelectrons is dramatically reduced, down to the level of 0.02%. We will report on the measurements of 1.5‧ PMTs from Hamamatsu and Electron Tubes Enterprises as candidate PMTs for the CTA project. The novel 1.5‧ PMTs have the worldwide best parameters.
Efficacy of a novel Pasteurella multocida vaccine against progressive atrophic rhinitis of swine
Hsuan, Shih-Ling; Liao, Chih-Ming; Huang, Chienjin; Winton, James R.; Chen, Zeng-Weng; Lee, Wei-Cheng; Liao, Jiunn-Wang; Chen, Ter-Hsin; Chiou, Chwei-Jang; Yeh, Kuang-Sheng; Chien, Maw-Sheng
2009-01-01
The efficacy of a novel vaccine composed of three short recombinant subunit Pasteurella multocida toxin (PMT) proteins in combination with a bi-valent P. multocida whole-cell bacterin (rsPMT–PM) was evaluated in field studies for prevention and control of progressive atrophic rhinitis (PAR) of swine at 15 conventional farrow-to-finish farms. Experimental piglets that were immunized twice with the rsPMT–PM vaccine developed detectable titers of neutralizing antibodies (greater than 1:8) that prevented the growth retardation and pathological lesions typically observed following challenge with authentic PMT. A total of 542 sows were vaccinated once or twice prior to parturition and serum neutralizing antibody titers were evaluated. Both single and double vaccination protocols induced neutralizing antibody titers of 1:16 or higher in 62% and 74% of sows, respectively. Notably, neither sows nor piglets at a farm experiencing a severe outbreak of PAR at the time of the vaccination trial had detectable antibody titers, but antibody titers increased significantly to 1:16 or higher in 40% of sows following double vaccination. During the year after vaccination, clinical signs of PAR decreased in fattening pigs and growth performance improved sufficiently to reduce the rearing period until marketing by 2 weeks. Collectively, these results indicate that the rsPMT–PM vaccine could be used to provide protective immunity for controlling the prevalence and severity of PAR among farm-raised swine.
Weyda, István; Yang, Lei; Vang, Jesper; Ahring, Birgitte K; Lübeck, Mette; Lübeck, Peter S
2017-04-01
In recent years, versatile genetic tools have been developed and applied to a number of filamentous fungi of industrial importance. However, the existing techniques have limitations when it comes to achieve the desired genetic modifications, especially for efficient gene targeting. In this study, we used Aspergillus carbonarius as a host strain due to its potential as a cell factory, and compared three gene targeting techniques by disrupting the ayg1 gene involved in the biosynthesis of conidial pigment in A. carbonarius. The absence of the ayg1 gene leads to phenotypic change in conidia color, which facilitated the analysis on the gene targeting frequency. The examined transformation techniques included Agrobacterium-mediated transformation (AMT) and protoplast-mediated transformation (PMT). Furthermore, the PMT for the disruption of the ayg1 gene was carried out with bipartite gene targeting fragments and the recently adapted CRISPR-Cas9 system. All three techniques were successful in generating Δayg1 mutants, but showed different efficiencies. The most efficient method for gene targeting was AMT, but further it was shown to be dependent on the choice of Agrobacterium strain. However, there are different advantages and disadvantages of all three gene targeting methods which are discussed, in order to facilitate future approaches for fungal strain improvements. Copyright © 2017 Elsevier B.V. All rights reserved.
Aspirex Thrombectomy in Occluded Dialysis Access: A Retrospective Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dyer, Jules, E-mail: Jules.Dyer@nhs.net; Rosa, Joao; Chachlani, Menka
PurposeThis study is the first to present the outcomes of the Straub Aspirex device for the salvage of occluded renal dialysis access fistulae.Materials and MethodsThis is a retrospective study, using data from the Renal Unit and Radiology Department database. It included all the patients between 2010 and 2014 who underwent percutaneous mechanical thrombectomy (PMT) treated by JD. Aspirex is an over-the-wire, 6–10 French catheter within which is a rapidly rotating helix which draws thrombus into a window near the tip which it then macerates and removes. Access survival was assessed using the Kaplan–Meier method, and multi-variant analysis was performed usingmore » the Cox proportional hazards model. Significance was considered if p < 0.05.ResultsA total of 27 procedures were performed for 19 patients. 13 had autologous arterio-venous fistulae, and 14 had synthetic (PTFE) arterio-venous grafts. 15 were males, 4 females. 100 % of the patients successfully had a channel of thrombus removed. This resulted in an 81.5 % initial clinical success, with primary patency rates of 53.6, 44.3 and 33 % by days 30, 90 and 480, respectively, without significant difference of any analysed covariates. No major complication (pulmonary embolus, paradoxical cerebral infarction, limb ischaemia or significant haemorrhage) occurred.ConclusionAspirex has rates of patency and complication similar to other PMT devices. No covariant studied affected outcome.« less
Spibey, C A; Jackson, P; Herick, K
2001-03-01
In recent years the use of fluorescent dyes in biological applications has dramatically increased. The continual improvement in the capabilities of these fluorescent dyes demands increasingly sensitive detection systems that provide accurate quantitation over a wide linear dynamic range. In the field of proteomics, the detection, quantitation and identification of very low abundance proteins are of extreme importance in understanding cellular processes. Therefore, the instrumentation used to acquire an image of such samples, for spot picking and identification by mass spectrometry, must be sensitive enough to be able, not only, to maximise the sensitivity and dynamic range of the staining dyes but, as importantly, adapt to the ever changing portfolio of fluorescent dyes as they become available. Just as the available fluorescent probes are improving and evolving so are the users application requirements. Therefore, the instrumentation chosen must be flexible to address and adapt to those changing needs. As a result, a highly competitive market for the supply and production of such dyes and the instrumentation for their detection and quantitation have emerged. The instrumentation currently available is based on either laser/photomultiplier tube (PMT) scanning or lamp/charge-coupled device (CCD) based mechanisms. This review briefly discusses the advantages and disadvantages of both System types for fluorescence imaging, gives a technical overview of CCD technology and describes in detail a unique xenon/are lamp CCD based instrument, from PerkinElmer Life Sciences. The Wallac-1442 ARTHUR is unique in its ability to scan both large areas at high resolution and give accurate selectable excitation over the whole of the UV/visible range. It operates by filtering both the excitation and emission wavelengths, providing optimal and accurate measurement and quantitation of virtually any available dye and allows excellent spectral resolution between different fluorophores. This flexibility and excitation accuracy is key to multicolour applications and future adaptation of the instrument to address the application requirements and newly emerging dyes.
Single photon detection imaging of Cherenkov light emitted during radiation therapy
NASA Astrophysics Data System (ADS)
Adamson, Philip M.; Andreozzi, Jacqueline M.; LaRochelle, Ethan; Gladstone, David J.; Pogue, Brian W.
2018-03-01
Cherenkov imaging during radiation therapy has been developed as a tool for dosimetry, which could have applications in patient delivery verification or in regular quality audit. The cameras used are intensified imaging sensors, either ICCD or ICMOS cameras, which allow important features of imaging, including: (1) nanosecond time gating, (2) amplification by 103-104, which together allow for imaging which has (1) real time capture at 10-30 frames per second, (2) sensitivity at the level of single photon event level, and (3) ability to suppress background light from the ambient room. However, the capability to achieve single photon imaging has not been fully analyzed to date, and as such was the focus of this study. The ability to quantitatively characterize how a single photon event appears in amplified camera imaging from the Cherenkov images was analyzed with image processing. The signal seen at normal gain levels appears to be a blur of about 90 counts in the CCD detector, after going through the chain of photocathode detection, amplification through a microchannel plate PMT, excitation onto a phosphor screen and then imaged on the CCD. The analysis of single photon events requires careful interpretation of the fixed pattern noise, statistical quantum noise distributions, and the spatial spread of each pulse through the ICCD.
Neutron detection with plastic scintillators coupled to solid state photomultiplier detectors
NASA Astrophysics Data System (ADS)
Christian, James F.; Johnson, Erik B.; Fernandez, Daniel E.; Vogel, Samuel; Frank, Rebecca; Stoddard, Graham; Stapels, Christopher; Pereira, Jorge; Zegers, Remco
2017-09-01
The recent reduction of dark current in Silicon Solid-state photomultipliers (SiSSPMs) makes them an attractive alternative to conventional photomultiplier tubes (PMTs) for scintillation detection applications. Nuclear Physics experiments often require large detector volumes made using scintillation materials, which require sensitive photodetectors, such as a PMTs. PMTs add to the size, fragility, and high-voltage requirements as well as distance requirements for experiments using magnetic fields. This work compares RMD's latest detector modules, denoted as the "year 2 prototype", of plastic scintillators that discriminate gamma and high-energy particle events from neutron events using pulse shape discrimination (PSD) coupled to a SiSSPM to the following two detector modules: a similar "year 1 prototype" and a scintillator coupled to a PMT module. It characterizes the noise floor, relative signal-to-noise ratio (SNR), the timing performance, the PSD figure-of-merit (FOM) and the neutron detection efficiency of RMD's detectors. This work also evaluates the scaling of SiSSPM detector modules to accommodate the volumes needed for many Nuclear Physics experiments. The Si SSPM detector module provides a clear advantage in Nuclear Physics experiments that require the following attributes: discrimination of neutron and gamma-ray events, operation in or near strong magnetic fields, and segmentation of the detector.
Design study of dedicated brain PET with polyhedron geometry.
Shi, Han; Du, Dong; Xu, JianFeng; Su, Zhihong; Peng, Qiyu
2015-01-01
Despite being the conventional choice, whole body PET cameras with a 76 cm diameter ring are not the optimal means of human brain imaging. In fact, a dedicated brain PET with a better geometrical structure has the potential to achieve a higher sensitivity, a higher signal-to-noise ratio, and a better imaging performance. In this study, a polyhedron geometrical dedicated brain PET (a dodecahedron design) is compared to three other candidates via their geometrical efficiencies by calculating the Solid Angle Fractions (SAF); the three other candidates include a spherical cap design, a cylindrical design, and the conventional whole body PET. The spherical cap and the dodecahedron have an identical SAF that is 58.4% higher than that of a 30 cm diameter cylinder and 5.44 times higher than that of a 76 cm diameter cylinder. The conceptual polygon-shape detectors (including pentagon and hexagon detectors based on the PMT-light-sharing scheme instead of the conventional square-shaped block detector module) are presented for the polyhedron PET design. Monte Carlo simulations are performed in order to validate the detector decoding. The results show that crystals in a pentagon-shape detector can be successfully decoded by Anger Logic. The new detector designs support the polyhedron PET investigation.