Sampling and position effects in the Electronically Steered Thinned Array Radiometer (ESTAR)
NASA Technical Reports Server (NTRS)
Katzberg, Stephen J.
1993-01-01
A simple engineering level model of the Electronically Steered Thinned Array Radiometer (ESTAR) is developed that allows an identification of the major effects of the sampling process involved with this technique. It is shown that the ESTAR approach is sensitive to aliasing and has a highly non-uniform sensitivity profile. It is further shown that the ESTAR approach is strongly sensitive to position displacements of the low-density sampling antenna elements.
Weber, Andreas; von Weyhern, Claus; Fend, Falko; Schneider, Jochen; Neu, Bruno; Meining, Alexander; Weidenbach, Hans; Schmid, Roland M; Prinz, Christian
2008-02-21
To evaluate the sensitivity of brush cytology and forceps biopsy in a homogeneous patient group with hilar cholangiocarcinoma. Brush cytology and forceps biopsy were routinely performed in patients with suspected malignant biliary strictures. Fifty-eight consecutive patients undergoing endoscopic retrograde cholangio-pancreatography (ERCP) including forceps biopsy and brush cytology in patients with hilar cholangiocarcinoma between 1995-2005. Positive results for malignancy were obtained in 24/58 patients (41.4%) by brush cytology and in 31/58 patients (53.4%) by forceps biopsy. The combination of both techniques brush cytology and forceps biopsy resulted only in a minor increase in diagnostic sensitivity to 60.3% (35/58 patients). In 20/58 patients (34.5%), diagnosis were obtained by both positive cytology and positive histology, in 11/58 (19%) by positive histology (negative cytology) and only 4/58 patients (6.9%) were confirmed by positive cytology (negative histology). Brush cytology and forceps biopsy have only limited sensitivity for the diagnosis of malignant hilar tumors. In our eyes, additional diagnostic techniques should be evaluated and should become routine in patients with negative cytological and histological findings.
NASA Astrophysics Data System (ADS)
Bradu, Adrian; Marques, Manuel J.; Bouchal, Petr; Podoleanu, Adrian Gh.
2013-03-01
The purpose of this study was to show how to favorably mix two e_ects to improve the sensitivity with depth in Fourier domain optical coherence tomography (OCT): Talbot bands (TB) and Gabor-based fusion (GF) technique. TB operation is achieved by directing the two beams, from the object arm and from the reference arm in the OCT interferometer, along parallel separate paths towards the spectrometer. By changing the lateral gap between the two beams in their path towards the spectrometer, the position for the maximum sensitivity versus the optical path difference in the interferometer is adjusted. For five values of the focus position, the gap between the two beams is readjusted to reach maximum sensitivity. Then, similar to the procedure employed in the GF technique, a composite image is formed by edging together the parts of the five images that exhibited maximum brightness. The combined procedure, TB/GF is examined for four different values of the beam diameters of the two beams. Also we demonstrate volumetric FD-OCT images with mirror term attenuation and sensitivity profile shifted towards higher OPD values by applying a Talbot bands configuration.
NBS work on neutron resonance radiography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schrack, R.A.
1987-01-01
NBS has been engaged in a wide-ranging program in Neutron Resonance Radiography utilizing both one- and two-dimensional position-sensitive neutron detectors. The ability to perform a position-sensitive assay of up to 16 isotopes in a complex matrix has been demonstrated for a wide variety of sample types, including those with high gamma activity. A major part of the program has been the development and application of the microchannel-plate-based position-sensitive neutron detector. This detector system has high resolution and sensitivity, together with adequate speed of response to be used with neutron time-of-flight techniques. This system has demonstrated the ability to simultaneously imagemore » three isotopes in a sample with no interference.« less
Weber, Andreas; von Weyhern, Claus; Fend, Falko; Schneider, Jochen; Neu, Bruno; Meining, Alexander; Weidenbach, Hans; Schmid, Roland M; Prinz, Christian
2008-01-01
AIM: To evaluate the sensitivity of brush cytology and forceps biopsy in a homogeneous patient group with hilar cholangiocarcinoma. METHODS: Brush cytology and forceps biopsy were routinely performed in patients with suspected malignant biliary strictures. Fifty-eight consecutive patients undergoing endoscopic retrograde cholangiopancreatography (ERCP) including forceps biopsy and brush cytology in patients with hilar cholangiocarcinoma between 1995-2005. RESULTS: Positive results for malignancy were obtained in 24/58 patients (41.4%) by brush cytology and in 31/58 patients (53.4%) by forceps biopsy. The combination of both techniques brush cytology and forceps biopsy resulted only in a minor increase in diagnostic sensitivity to 60.3% (35/58 patients). In 20/58 patients (34.5%), diagnosis were obtained by both positive cytology and positive histology, in 11/58 (19%) by positive histology (negative cytology) and only 4/58 patients (6.9%) were confirmed by positive cytology (negative histology). CONCLUSION: Brush cytology and forceps biopsy have only limited sensitivity for the diagnosis of malignant hilar tumors. In our eyes, additional diagnostic techniques should be evaluated and should become routine in patients with negative cytological and histological findings. PMID:18286693
Nicoś, M; Krawczyk, P; Wojas-Krawczyk, K; Bożyk, A; Jarosz, B; Sawicki, M; Trojanowski, T; Milanowski, J
2017-12-01
RT-PCR technique has showed a promising value as pre-screening method for detection of mRNA containing abnormal ALK sequences, but its sensitivity and specificity is still discussable. Previously, we determined the incidence of ALK rearrangement in CNS metastases of NSCLC using IHC and FISH methods. We evaluated ALK gene rearrangement using two-step RT-PCR method with EML4-ALK Fusion Gene Detection Kit (Entrogen, USA). The studied group included 145 patients (45 females, 100 males) with CNS metastases of NSCLC and was heterogeneous in terms of histology and smoking status. 21% of CNS metastases of NSCLC (30/145) showed presence of mRNA containing abnormal ALK sequences. FISH and IHC tests confirmed the presence of ALK gene rearrangement and expression of ALK abnormal protein in seven patients with positive result of RT-PCR analysis (4.8% of all patients, 20% of RT-PCR positive patients). RT-PCR method compared to FISH analysis achieved 100% of sensitivity and only 82.7% of specificity. IHC method compared to FISH method indicated 100% of sensitivity and 97.8% of specificity. In comparison to IHC, RT-PCR showed identical sensitivity with high number of false positive results. Utility of RT-PCR technique in screening of ALK abnormalities and in qualification patients for molecularly targeted therapies needs further validation.
Beam position monitor for energy recovered linac beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Powers, Thomas; Evtushenko, Pavel
A method of determining the beam position in an energy recovered linac (ERL). The method makes use of in phase and quadrature (I/Q) demodulation techniques to separate the pickup signal generated by the electromagnetic fields generated by the first and second pass beam in the energy recovered linac. The method includes using analog or digital based I/Q demodulation techniques in order to measure the relative amplitude of the signals from a position sensitive beam pickup such as a button, strip line or microstripline beam position monitor.
Ocular radioimmunoscintigraphy: sensitivity and practical considerations.
Bomanji, J; Nimmon, C C; Hungerford, J L; Solanki, K; Granowska, M; Britton, K E
1988-06-01
Ocular radioimmunoscintigraphy was performed in 20 patients using 99mTc-labeled monoclonal antibody 225.28S, F(ab')2 fragments. Radioimmunoscintigraphy was positive in 13 patients and the diagnosis of ocular melanoma was confirmed by enucleation of the eye or clinical follow-up. Scintigraphy was positive in one patient with lymph node metastasis from an ocular melanoma. In six patients immunoscintigraphy was negative. Using this technique a sensitivity of 92.8% was achieved for detecting ocular melanomas. Single photon emission tomography helped to separate the lesions situated in the nasal quadrant of the eye from the adjacent nasopharyngeal activity. With appropriate imaging techniques small tumors of the order of 3 x 5 x 3 mm could be detected clearly.
Ibraheem, Kareem; Toraih, Eman A; Haddad, Antoine B; Farag, Mahmoud; Randolph, Gregory W; Kandil, Emad
2018-05-14
Minimally invasive parathyroidectomy requires accurate preoperative localization techniques. There is considerable controversy about the effectiveness of selective parathyroid venous sampling (sPVS) in primary hyperparathyroidism (PHPT) patients. The aim of this meta-analysis is to examine the diagnostic accuracy of sPVS as a preoperative localization modality in PHPT. Studies evaluating the diagnostic accuracy of sPVS for PHPT were electronically searched in the PubMed, EMBASE, Web of Science, and Cochrane Controlled Trials Register databases. Two independent authors reviewed the studies, and revised quality assessment of diagnostic accuracy study tool was used for the quality assessment. Study heterogeneity and pooled estimates were calculated. Two hundred and two unique studies were identified. Of those, 12 studies were included in the meta-analysis. Pooled sensitivity, specificity, and positive likelihood ratio (PLR) of sPVS were 74%, 41%, and 1.55, respectively. The area-under-the-receiver operating characteristic curve was 0.684, indicating an average discriminatory ability of sPVS. On comparison between sPVS and noninvasive imaging modalities, sensitivity, PLR, and positive posttest probability were significantly higher in sPVS compared to noninvasive imaging modalities. Interestingly, super-selective venous sampling had the highest sensitivity, accuracy, and positive posttest probability compared to other parathyroid venous sampling techniques. This is the first meta-analysis to examine the accuracy of sPVS in PHPT. sPVS had higher pooled sensitivity when compared to noninvasive modalities in revision parathyroid surgery. However, the invasiveness of this technique does not favor its routine use for preoperative localization. Super-selective venous sampling was the most accurate among all other parathyroid venous sampling techniques. Laryngoscope, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harwood, S.J.; Anderson, M.W.; Klein, R.C.
1984-01-01
Emission computed tomography (ECT) studies were performed on a GE 400 A/T camera and ADAC computers (system 3 and system 3300). Thirty-three sets of ECT and planar images were obtained in 20 patients over a six month period. Imaging was performed 48 hours after the intravenous administration of 5 mc of Gallium 67 citrate. No bowel preparation was employed. Comparison is made of the initial nuclear medicine report derived from planar and ECT imaging aided by clinical knowledge versus the consensus opinion of two nuclear medicine physicians reading the planar images along with minimal clinical information. The lymphoma series consistsmore » of 18 scans in 10 patients. There were 5 scans in which a false negative planar interpretation was changed to a true positive ECT interpretation. Sensitivity of planar imaging for lymphoma was 58% which rose to 100% with addition of ECT information. There were no false positives by either technique. There were 5 sets of scans in 5 lung carcinoma patients. Sensitivity of the planar images was 60% because of 2 false negative results. Sensitivity of the ECT technique was 100%. There were no false positives. The infection series consists of 10 scans in 5 patients. Sensitivity of ECT was 100%, sensitivity of planar was 66%. There was 1 false positive planar. For the total series the accuracy of planar imaging was 69% and the predictive value of a negative planar interpretation was 44%. Corresponding values for ECT imaging were 100%. The authors' experience demonstrates significant increase in sensitivity without loss of specificity resulting from the use of Emission Computed Tomography in both chest and abdomen in patients with lymphoma, infection, and lung cancer.« less
An overview of LIGO and Virgo -- status and plans
NASA Astrophysics Data System (ADS)
Miller, John
2014-06-01
Interferometric gravitational-wave detectors, the most sensitive position meters ever operated, aim to detect the motion of massive bodies throughout the universe by pushing precision measurement to the standard quantum limit and beyond. A global network of these detectors is currently under construction, promising unprecedented sensitivity and the ability to determine the sky position of any detected signals. I will describe the current status and expected performance of this network with a focus on limiting noise sources and the techniques currently being developed to combat them.
In vivo sensitivity estimation and imaging acceleration with rotating RF coil arrays at 7 Tesla.
Li, Mingyan; Jin, Jin; Zuo, Zhentao; Liu, Feng; Trakic, Adnan; Weber, Ewald; Zhuo, Yan; Xue, Rong; Crozier, Stuart
2015-03-01
Using a new rotating SENSitivity Encoding (rotating-SENSE) algorithm, we have successfully demonstrated that the rotating radiofrequency coil array (RRFCA) was capable of achieving a significant reduction in scan time and a uniform image reconstruction for a homogeneous phantom at 7 Tesla. However, at 7 Tesla the in vivo sensitivity profiles (B1(-)) become distinct at various angular positions. Therefore, sensitivity maps at other angular positions cannot be obtained by numerically rotating the acquired ones. In this work, a novel sensitivity estimation method for the RRFCA was developed and validated with human brain imaging. This method employed a library database and registration techniques to estimate coil sensitivity at an arbitrary angular position. The estimated sensitivity maps were then compared to the acquired sensitivity maps. The results indicate that the proposed method is capable of accurately estimating both magnitude and phase of sensitivity at an arbitrary angular position, which enables us to employ the rotating-SENSE algorithm to accelerate acquisition and reconstruct image. Compared to a stationary coil array with the same number of coil elements, the RRFCA was able to reconstruct images with better quality at a high reduction factor. It is hoped that the proposed rotation-dependent sensitivity estimation algorithm and the acceleration ability of the RRFCA will be particularly useful for ultra high field MRI. Copyright © 2014 Elsevier Inc. All rights reserved.
In vivo sensitivity estimation and imaging acceleration with rotating RF coil arrays at 7 Tesla
NASA Astrophysics Data System (ADS)
Li, Mingyan; Jin, Jin; Zuo, Zhentao; Liu, Feng; Trakic, Adnan; Weber, Ewald; Zhuo, Yan; Xue, Rong; Crozier, Stuart
2015-03-01
Using a new rotating SENSitivity Encoding (rotating-SENSE) algorithm, we have successfully demonstrated that the rotating radiofrequency coil array (RRFCA) was capable of achieving a significant reduction in scan time and a uniform image reconstruction for a homogeneous phantom at 7 Tesla. However, at 7 Tesla the in vivo sensitivity profiles (B1-) become distinct at various angular positions. Therefore, sensitivity maps at other angular positions cannot be obtained by numerically rotating the acquired ones. In this work, a novel sensitivity estimation method for the RRFCA was developed and validated with human brain imaging. This method employed a library database and registration techniques to estimate coil sensitivity at an arbitrary angular position. The estimated sensitivity maps were then compared to the acquired sensitivity maps. The results indicate that the proposed method is capable of accurately estimating both magnitude and phase of sensitivity at an arbitrary angular position, which enables us to employ the rotating-SENSE algorithm to accelerate acquisition and reconstruct image. Compared to a stationary coil array with the same number of coil elements, the RRFCA was able to reconstruct images with better quality at a high reduction factor. It is hoped that the proposed rotation-dependent sensitivity estimation algorithm and the acceleration ability of the RRFCA will be particularly useful for ultra high field MRI.
Moody, Colleen A.; Eckel, Stephen F.; Amerine, Lindsey B.
2015-01-01
Background: Microbial contamination of compounded medications is a serious concern within hospital pharmacies as it can lead to severe patient injury. The United States Pharmacopeia <797> mandates that pharmacy personnel responsible for preparing compounded sterile preparations must annually demonstrate competency in aseptic technique by performing a media-fill challenge test. Objective: The purpose of this study is to evaluate the sensitivity of a commonly used media-fill test through proper and improper compounding techniques. Methods: Two aseptically trained pharmacy technicians performed media-fill challenge testing by carrying out 5 separate manipulations 5 times each for a total of 25 trials. Sterile vials, syringes, and intravenous bags were prepared. The first manipulation followed best-practice aseptic technique and sterile compounding procedures. Each of the following 4 manipulations removed one aspect of best-practice aseptic technique. The prepared products were incubated at 20°C to 25°C. A positive result for microbial contamination is indicated by visible turbidity within the vials, syringes, and intravenous bags at the following check points: 24 hours, 72 hours, 7 days, 14 days, 21 days, and >30 days. Results: Twenty-five trials, each containing 10 distinct admixtures, resulted in a total of 250 compounded preparations. No single preparation showed signs of turbidity, sedimentation, or visible microbial growth at any of the 6 checkpoints yielding a 0% contamination rate. However, the positive controls inoculated with bacteria did have positive microbial growth results. Conclusion: A more sensitive test needs to be developed to provide assurances that all poor aseptic practices are detected in compounding personnel.
FAZ, Mirna; MARTÍNEZ, José Simón; QUIJANO-HERNÁNDEZ, Israel; FAJARDO, Raúl
2016-01-01
Canine parvovirus type 2 (CPV-2) is the main etiological agent of viral enteritis in dogs. Actually in literature, CPV-2 has been reported with clinical signs that vary from the classical disease, and immunochromatography test and PCR technique have been introduced to veterinary hospitals to confirm CPV-2 diagnosis and other infections. However, the reliability of these techniques has been poorly analyzed. In this study, we evaluated the sensitivity and specificity of veterinary clinical diagnosis, immunochromatography test and PCR technique. Our data indicate that variations in the clinical signs of CPV-2 complicate the gathering of an appropriate diagnosis; and immunochromatography test and PCR technique do not have adequate sensitivity to diagnose positive cases. PMID:27818461
The Diagnostic Accuracy of Cytology for the Diagnosis of Hepatobiliary and Pancreatic Cancers.
Al-Hajeili, Marwan; Alqassas, Maryam; Alomran, Astabraq; Batarfi, Bashaer; Basunaid, Bashaer; Alshail, Reem; Alaydarous, Shahad; Bokhary, Rana; Mosli, Mahmoud
2018-06-13
Although cytology testing is considered a valuable method to diagnose tumors that are difficult to access such as hepato-biliary-pancreatic (HBP) malignancies, its diagnostic accuracy remains unclear. We therefore aimed to investigate the diagnostic accuracy of cytology testing for HBP tumors. We performed a retrospective study of all cytology samples that were used to confirm radiologically detected HBP tumors between 2002 and 2016. The cytology techniques used in our center included fine needle aspiration (FNA), brush cytology, and aspiration of bile. Sensitivity, specificity, positive and negative predictive values, and likelihood ratios were calculated in comparison to histological confirmation. From a total of 133 medical records, we calculated an overall sensitivity of 76%, specificity of 74%, a negative likelihood ratio of 0.30, and a positive likelihood ratio of 2.9. Cytology was more accurate in diagnosing lesions of the liver (sensitivity 79%, specificity 57%) and biliary tree (sensitivity 100%, specificity 50%) compared to pancreatic (sensitivity 60%, specificity 83%) and gallbladder lesions (sensitivity 50%, specificity 85%). Cytology was more accurate in detecting primary cancers (sensitivity 77%, specificity 73%) when compared to metastatic cancers (sensitivity 73%, specificity 100%). FNA was the most frequently used cytological technique to diagnose HBP lesions (sensitivity 78.8%). Cytological testing is efficient in diagnosing HBP cancers, especially for hepatobiliary tumors. Given its relative simplicity, cost-effectiveness, and paucity of alternative diagnostic methods, cytology should still be considered as a first-line tool for diagnosing HBP malignancies. © 2018 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Tartaglione, A.; Di Lorenzo, F.; Mayer, R. E.
2009-07-01
Cargo interrogation in search for special nuclear materials like highly-enriched uranium or 239Pu is a first priority issue of international borders security. In this work we present a thermal-pulsed neutron-based approach to a technique which combines the time-of-flight method and demonstrates a capability to detect small quantities of highly-enriched uranium shielded with high or low Z materials providing, in addition, a manner to know the approximate position of the searched material.
Improved spatial resolution in PET scanners using sampling techniques
Surti, Suleman; Scheuermann, Ryan; Werner, Matthew E.; Karp, Joel S.
2009-01-01
Increased focus towards improved detector spatial resolution in PET has led to the use of smaller crystals in some form of light sharing detector design. In this work we evaluate two sampling techniques that can be applied during calibrations for pixelated detector designs in order to improve the reconstructed spatial resolution. The inter-crystal positioning technique utilizes sub-sampling in the crystal flood map to better sample the Compton scatter events in the detector. The Compton scatter rejection technique, on the other hand, rejects those events that are located further from individual crystal centers in the flood map. We performed Monte Carlo simulations followed by measurements on two whole-body scanners for point source data. The simulations and measurements were performed for scanners using scintillators with Zeff ranging from 46.9 to 63 for LaBr3 and LYSO, respectively. Our results show that near the center of the scanner, inter-crystal positioning technique leads to a gain of about 0.5-mm in reconstructed spatial resolution (FWHM) for both scanner designs. In a small animal LYSO scanner the resolution improves from 1.9-mm to 1.6-mm with the inter-crystal technique. The Compton scatter rejection technique shows higher gains in spatial resolution but at the cost of reduction in scanner sensitivity. The inter-crystal positioning technique represents a modest acquisition software modification for an improvement in spatial resolution, but at a cost of potentially longer data correction and reconstruction times. The Compton scatter rejection technique, while also requiring a modest acquisition software change with no increased data correction and reconstruction times, will be useful in applications where the scanner sensitivity is very high and larger improvements in spatial resolution are desirable. PMID:19779586
Evaluation of modified Dennis parasitological technique for diagnosis of bovine fascioliasis.
Correa, Stefanya; Martínez, Yudy Liceth; López, Jessika Lissethe; Velásquez, Luz Elena
2016-02-23
Bovine fascioliasis causes important economic losses, estimated at COP$ 12,483 billion per year; its prevalence is 25% in dairy cattle. Parasitological techniques are required for it diagnosis. The Dennis technique, modified in 2002, is the one used in Colombia, but its sensitivity, specificity and validity are not known. To evaluate the validity and performance of the modified Dennis technique for diagnosis of bovine fascioliasis using as reference test the observation of parasites in the liver. We conducted a diagnostic evaluation study. We selected a convenience sample of discarded bovines sacrificed between March and June, 2013, in Frigocolanta for the study. We collected 25 g of feces from each animal and their liver and bile ducts were examined for Fasciola hepatica. The sensitivity, specificity, predictive positive value, predictive negative value, and validity index were calculated with 95% confidence intervals. The post-mortem evaluation was used as the gold standard. We analyzed 180 bovines. The sensitivity and specificity of the modified Dennis technique were 73.2% (95% CI=58.4% - 87.9%) and 84.2% (95% CI= 77.7% - 90.6%), respectively. The positive predictive value was 57.7% (95% CI= 43.3% - 72.1%) and the negative one 91.4% (95% CI= 86.2% - 96.6%). The prevalence of bovine fascioliasis was 22.8% (95% CI= 16.4% - 29.2%). The validity and the performance of the modified Dennis technique were higher than those of the traditional one, which makes it a good screening test for diagnosing fascioliasis for population and prevalence studies and during animal health campaigns.
Swider, Paweł; Lewtak, Jan P; Gryko, Daniel T; Danikiewicz, Witold
2013-10-01
The porphyrinoids chemistry is greatly dependent on the data obtained in mass spectrometry. For this reason, it is essential to determine the range of applicability of mass spectrometry ionization methods. In this study, the sensitivity of three different atmospheric pressure ionization techniques, electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization, was tested for several porphyrinods and their metallocomplexes. Electrospray ionization method was shown to be the best ionization technique because of its high sensitivity for derivatives of cyanocobalamin, free-base corroles and porphyrins. In the case of metallocorroles and metalloporphyrins, atmospheric pressure photoionization with dopant proved to be the most sensitive ionization method. It was also shown that for relatively acidic compounds, particularly for corroles, the negative ion mode provides better sensitivity than the positive ion mode. The results supply a lot of relevant information on the methodology of porphyrinoids analysis carried out by mass spectrometry. The information can be useful in designing future MS or liquid chromatography-MS experiments. Copyright © 2013 John Wiley & Sons, Ltd.
[The diagnosis of malaria by the thick film and the QBC: a comparative study of both technics].
Cabezos, J; Bada, J L
1993-06-12
The diagnosis of paludism is important because of the severity of the clinical picture caused by Plasmodium falciparum, the increasing number of travellers to endemic zones and the emigration from these zones. A comparative study of the QBC techniques (staining with acridin orange and observation with ultraviolet light) and the thick film with Giemsa staining was carried out. The QBC and thick film were performed parallelly for 17 months in a total of 623 samples pertaining to subjects from endemic zones of paludism (emigrants, immigrants and travellers). Of the 623 samples studied 49 were positive for paludism by both techniques. Ten were positive with only the thick film and six were positive only with QBC. The sensitivity of QBC versus thick film was 83% and specificity 98.9%. The time used to determine diagnosis with the QBC technique ranged from 6 to 12 minutes from withdrawal of the sample, while with the thick film the time spent was more than 2 hours. The cases positive by thick film and negative with QBC corresponded to patients with very low parasitation. The intensity of parasitation was difficult to determine quantitatively by QBC. Although the QBC technique has the advantage of speed it is inexact with respect to the quantification of parasitemia. Moreover, it is less sensitive than the thick film in patient with very low parasitations and cannot thus substitute the thick film.
Optimization techniques applied to spectrum management for communications satellites
NASA Astrophysics Data System (ADS)
Ottey, H. R.; Sullivan, T. M.; Zusman, F. S.
This paper describes user requirements, algorithms and software design features for the application of optimization techniques to the management of the geostationary orbit/spectrum resource. Relevant problems include parameter sensitivity analyses, frequency and orbit position assignment coordination, and orbit position allotment planning. It is shown how integer and nonlinear programming as well as heuristic search techniques can be used to solve these problems. Formalized mathematical objective functions that define the problems are presented. Constraint functions that impart the necessary solution bounds are described. A versatile program structure is outlined, which would allow problems to be solved in stages while varying the problem space, solution resolution, objective function and constraints.
Large-area PSPMT based gamma-ray imager with edge reclamation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ziock, K-P; Nakae, L
2000-09-21
We describe a coded aperture, gamma-ray imager which uses a CsI(Na) scintillator coupled to an Hamamatsu R3292 position-sensitive photomultiplier tube (PSPMT) as the position-sensitive detector. We have modified the normal resistor divider readout of the PSPMT to allow use of nearly the full 10 cm diameter active area of the PSPMT with a single scintillator crystal one centimeter thick. This is a significant performance improvement over that obtained with the standard readout technique where the linearity and position resolution start to degrade at radii as small as 3.5 cm with a crystal 0.75 crn thick. This represents a recovery ofmore » over 60% of the PSPMT active area. The performance increase allows the construction of an imager with a field of view 20 resolution elements in diameter with useful quantum efficiency from 60-700 keV. In this paper we describe the readout technique, its implementation in a coded aperture imager and the performance of that imager.« less
Abdel Rahman, Afaf S; Fahim, Nehal M A; El Sayed, Abeer A; El Hady, Soha A R; Ahmad, Yasser S
2005-01-01
Renal transplantation, in most countries, is based on human leukocyte antigen (HLA) matching of the donor kidney with the recipient. Traditional human leukocyte antigen matching is based on defining human leukocyte antigen specificities by antibodies utilizing cytotoxicity crossmatch techniques. Newer techniques have emerged, which challenge the accuracy of serological typing and crossmatching. We compared the results of the standard complement-dependent cytotoxicity crossmatch (CDCXM) with the anti-human globulin augmented cytotoxicity (AHG-CDC), and Flowcytometry crossmatch (FCXM) for the detection of anti-HLA antibodies in 150 pre-transplant patients. The development of post-transplantation sensitization was screened utilizing these three techniques within two weeks post-operative and correlated with rejection episodes. Comparison between the results of CDCXM and AHG-CDC in 150 recipients, revealed no significant correlation (P>0.05). When comparing these results with that of FCXM in 50 recipients a significant correlation was shown (P<0.05). Relative to CDCXM, the sensitivity of AHG-CDC was 100%, specificity 97.4%, positive predictive value 92.3%, and negative predictive value 100%. On the other hand, the sensitivity of FCXM was 100%, specificity 76.3%, positive predictive value 57.1%, and negative predictive value 100%. According to the results of CDCXM, AHG-CDC, and FCXM, no difference was detected between pre- and posttransplant anti-HLA sensitization within two weeks after the operation. Patients with negative cytotoxicity crossmatch (CDCXM and AHG-CDC) and positive FCXM may have an increased risk of early graft loss and may represent a relative contraindication to transplantation. Given the important theoretical advantages of FCXM over the CDC XM, further testing of the clinical relevance is warranted.
Salleh, Fatmah M; Al-Mekhlafi, Abdulsalam M; Nordin, Anisah; Yasin, 'Azlin M; Al-Mekhlafi, Hesham M; Moktar, Norhayati
2011-01-01
This study was conducted to evaluate the modification of the usual Gram-chromotrope staining technique developed in-house known as Gram-chromotrope Kinyoun (GCK) in comparison with the Weber Modified Trichrome (WMT) staining technique; as the reference technique. Two hundred and ninety fecal specimens received by the Microbiology Diagnostic Laboratory of Hospital Universiti Kebangsaan Malaysia were examined for the presence of microsporidial spores. The sensitivity and specificity of GCK compared to the reference technique were 98% and 98.3%, respectively. The positive and negative predictive values were 92.5% and 99.6%, respectively. The agreement between the reference technique and the GCK staining technique was statistically significant by Kappa statistics (K = 0.941, P < 0.001). It is concluded that the GCK staining technique has high sensitivity and specificity in the detection of microsporidial spores in fecal specimens. Hence, it is recommended to be used in the diagnosis of intestinal microsporidiosis. Copyright © 2011 Elsevier Inc. All rights reserved.
Lee, Grace S; McKenzie, Travis J; Mullan, Brian P; Farley, David R; Thompson, Geoffrey B; Richards, Melanie L
2016-03-01
Focused parathyroidectomy in primary hyperparathyroidism (1°HPT) is possible with accurate preoperative localization and intraoperative PTH monitoring (IOPTH). The added benefit of multimodal imaging techniques for operative success is unknown. Patients with 1°HPT, who underwent parathyroidectomy in 2012-2014 at a single institution, were retrospectively reviewed. Only the patients who underwent the standardized multimodal imaging workup consisting of (123)I/(99)Tc-sestamibi subtraction scintigraphy, SPECT, and SPECT/CT were assessed. Of 360 patients who were identified, a curative operation was performed in 96%, using pre-operative imaging and IOPTH. Imaging analysis showed that (123)I/(99)Tc-sestamibi had a sensitivity of 86% (95% CI 82-90%), positive predictive value (PPV) 93%, and accuracy 81%, based on correct lateralization. SPECT had a sensitivity of 77% (95% CI 72-82%), PPV 92% and accuracy 72%. SPECT/CT had a sensitivity of 75% (95% CI 70-80%), PPV of 94%, and accuracy 71%. There were 3 of 45 (7%) patients with negative sestamibi imaging that had an accurate SPECT and SPECT/CT. Of 312 patients (87%) with positive uptake on sestamibi (93% true positive, 7% false positive), concordant findings were present in 86% SPECT and 84% SPECT/CT. In cases where imaging modalities were discordant, but at least one method was true-positive, (123)I/(99)Tc-sestamibi was significantly better than both SPECT and SPECT/CT (p < 0.001). The inclusion of SPECT and SPECT/CT in 1°HPT imaging protocol increases patient cost up to 2.4-fold. (123)I/(99)Tc-sestamibi subtraction imaging is highly sensitive for preoperative localization in 1°HPT. SPECT and SPECT/CT are commonly concordant with (123)I/(99)Tc-sestamibi and rarely increase the sensitivity. Routine inclusion of multimodality imaging technique adds minimal clinical benefit but increases cost to patient in high-volume setting.
Roe, M; Kishiyama, C; Davidson, K; Schaefer, L; Todd, J
1995-01-01
We directly compared three techniques for the diagnosis of group A streptococcal pharyngitis in 500 symptomatic children seen in the Emergency Department or Child Care Clinic of The Children's Hospital of Denver. Throats were vigorously swabbed with two rayon swabs, which were transported immediately to the Microbiology Laboratory. Each swab was cultured aerobically on Strep A Isolation Agar (Remel) and then tested for antigen-one swab by the Strep A OIA optical immune assay (BioStar) and the other by the TestPack Plus Strep A (Abbott) technique. Each test was performed blind to the others. The refrigerated pledget was cultured in Todd-Hewitt broth if an antigen test was positive and both direct plate cultures were negative (the "gold standard" was any culture positive). All isolates were serologically grouped. Of 500 complete patient cultures, 151 (30%) were positive for group A streptococcal growth. The two antigen tests gave comparable results with an average sensitivity of 83%. Each was significantly (P < 0.02) less sensitive than its corresponding culture. The BioStar Strep A OIA optical immune assay produced significantly (P < 0.003) more false-positive results than did the Abbott test. Rapid antigen testing is not sensitive enough to eliminate the need for backup cultures. PMID:7650184
Saijo, Masayuki; Qing, Tang; Niikura, Masahiro; Maeda, Akihiko; Ikegami, Tetsuro; Sakai, Koji; Prehaud, Christophe; Kurane, Ichiro; Morikawa, Shigeru
2002-01-01
A HeLa cell line continuously expressing recombinant nucleoprotein (rNP) of the Crimean-Congo hemorrhagic fever virus (CCHFV) was established by transfection with an expression vector containing the cDNA of CCHFV NP (pKS336-CCHFV-NP). These cells were used as antigens for indirect immunofluorescence (IF) to detect immunoglobulin G antibodies to CCHFV. The sensitivity and specificity of this IF technique were examined by using serum samples and were compared to those of the IF technique using CCHFV-infected Vero E6 cells (authentic antigen). Staining of the CCHFV rNP expressed in HeLa cells showed a unique granular pattern similar to that of CCHFV-infected Vero E6 cells. Positive staining could easily be distinguished from a negative result. All 13 serum samples determined to be positive by using the authentic antigen were also determined to be positive by using CCHFV rNP-expressing HeLa cells (recombinant antigen). The 108 serum samples determined to be negative by using the authentic antigen were also determined to be negative by using the recombinant antigen. Thus, both the sensitivity and the specificity of this IF technique were 100% compared to the IF with authentic antigen. The novel IF technique using CCHFV rNP-expressing HeLa cells can be used not only for diagnosis of CCHF but also for epidemiological studies on CCHFV infections. PMID:11825944
Practical Considerations for Optimizing Position Sensitivity in Arrays of Position-sensitive TES's
NASA Technical Reports Server (NTRS)
Smith, Stephen J.; Bandler, Simon R.; Figueroa-Feliciano, Encetali; Iyomoto, Naoko; Kelley, Richard L.; Kilbourne, Caroline A.; Porder, Frederick S.; Sadleir, John E.
2007-01-01
We are developing Position-Sensitive Transitions-Edge Sensors (PoST's) for future X-ray astronomy missions such as NASA's Constellation-X. The PoST consists of one or more Transitions Edge Sensors (TES's) thermally connected to a large X-ray absorber, which through heat diffusion, gives rise to position dependence. The development of PoST's is motivated by the desire to achieve the largest the focal-plan coverage with the fewest number of readout channels. In order to develop a practical array, consisting of an inner pixellated core with an outer array of large absorber PoST's, we must be able to simultaneously read out all (-1800) channels in the array. This is achievable using time division multiplexing (TDM), but does set stringent slew rate requirements on the array. Typically, we must damp the pulses to reduce the slew rate of the input signal to the TDM. This is achieved by applying a low-pass analog filter with large inductance to the signal. This attenuates the high frequency components of the signal, essential for position discrimination in PoST's, relative to the white noise of the readout chain and degrades the position sensitivity. Using numerically simulated data, we investigate the position sensing ability of typical PoST designs under such high inductance conditions. We investigate signal-processing techniques for optimal determination of the event position and discuss the practical considerations for real-time implementation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Datz, F.L.; Jacobs, J.; Baker, W.
1984-03-01
Imaging with leukocytes labeled with indium-111 oxine is a sensitive technique for detecting sites of occult infection. Traditionally, imaging is performed 24 hr after injection. The authors undertook a prospective study of 35 patients (40 studies) with possible occult infection to see whether a 24-hr delay in imaging is really necessary. Patients were imaged at 1-4 hr and again at 24 hr after injection. The early images had a sensitivity of only 33%, compared with 95% for the 24-hr images. Of the seven studies that were positive on both early and delayed images, 71% had more intense uptake at 24more » hr. There were no false-positive early images. It was concluded that imaging 1-4 hr after injection with In-111 oxine-labeled leukocytes has a low sensitivity for detecting occult infection. However, a positive early image is specific for a site of infection.« less
Jansen, Famke; Dorny, Pierre; Berkvens, Dirk; Van Hul, Anke; Van den Broeck, Nick; Makay, Caroline; Praet, Nicolas; Eichenberger, Ramon Marc; Deplazes, Peter; Gabriël, Sarah
2017-09-15
Bovine cysticercosis (BCC), caused by the helminth Taenia saginata, is currently diagnosed solely by official meat inspection (MI) based on macroscopic detection of viable cysticerci or typical lesions of degenerated larvae. MI has a known low sensitivity (<16%), leading to a large proportion of infected cattle carcasses entering the human food chain and posing a risk to public health. Prevalence in Belgium based on MI results is estimated at around 0.22%. Due to the low sensitivity of MI, alternative techniques to detect BCC should be considered. This study evaluates MI, MI with additional incisions in the heart, specific antibody detection against excretory/secretory (E/S) in the Ab-ELISA and circulating antigens in the B158/B60 Ag-ELISA on 715 (101 MI-positive and 614 MI-negative) samples collected from carcasses at slaughterhouses in Belgium. Full dissection of the predilection sites was considered the reference test. During the study, mostly carcasses with (very) light infections were detected containing predominantly degenerated or calcified cysticerci and only few viable cysticerci. Dissection of the predilection sites detected 144 (23%) additional infections in the 614 MI-negative carcasses. When sequentially performing first the dissection of the predilection sites, followed by the Ag-ELISA and the Ab-ELISA, an additional 36% of MI-negative carcasses were found positive for BCC, resulting in a prevalence very much higher than the above mentioned 0.22%. The B158/B60 Ag-ELISA showed a sensitivity of 40% for the detection of carcasses containing viable cysticerci and a specificity of 100%, and detected 70 positive carcasses of which only 14 had been identified as positive during MI. If Ag-ELISA were implemented as a detection technique for BCC in the slaughterhouses, many infected carcasses would still not be detected due to the sensitivity of 40%. But as sensitivity increases with increasing number of cysticerci in the carcass, the infected carcasses passing inspection will be the ones containing only a few viable cysticerci and thus posing a smaller food safety problem. Ag-ELISA is preferred over the ES Ab-ELISA in this study, which had a sensitivity of 13.3% and a specificity of 91.7% in a population with overall low infection burdens. Copyright © 2017 Elsevier B.V. All rights reserved.
In vivo optical elastography: stress and strain imaging of human skin lesions
NASA Astrophysics Data System (ADS)
Es'haghian, Shaghayegh; Gong, Peijun; Kennedy, Kelsey M.; Wijesinghe, Philip; Sampson, David D.; McLaughlin, Robert A.; Kennedy, Brendan F.
2015-03-01
Probing the mechanical properties of skin at high resolution could aid in the assessment of skin pathologies by, for example, detecting the extent of cancerous skin lesions and assessing pathology in burn scars. Here, we present two elastography techniques based on optical coherence tomography (OCT) to probe the local mechanical properties of skin. The first technique, optical palpation, is a high-resolution tactile imaging technique, which uses a complaint silicone layer positioned on the tissue surface to measure spatially-resolved stress imparted by compressive loading. We assess the performance of optical palpation, using a handheld imaging probe on a skin-mimicking phantom, and demonstrate its use on human skin. The second technique is a strain imaging technique, phase-sensitive compression OCE that maps depth-resolved mechanical variations within skin. We show preliminary results of in vivo phase-sensitive compression OCE on a human skin lesion.
The dream of a one-stop-shop: Meta-analysis on myocardial perfusion CT.
Pelgrim, Gert Jan; Dorrius, Monique; Xie, Xueqian; den Dekker, Martijn A M; Schoepf, U Joseph; Henzler, Thomas; Oudkerk, Matthijs; Vliegenthart, Rozemarijn
2015-12-01
To determine the diagnostic performance of computed tomography (CT) perfusion techniques for the detection of functionally relevant coronary artery disease (CAD) in comparison to reference standards, including invasive coronary angiography (ICA), single photon emission computed tomography (SPECT), and magnetic resonance imaging (MRI). PubMed, Web of Knowledge and Embase were searched from January 1, 1998 until July 1, 2014. The search yielded 9475 articles. After duplicate removal, 6041 were screened on title and abstract. The resulting 276 articles were independently analyzed in full-text by two reviewers, and included if the inclusion criteria were met. The articles reporting diagnostic parameters including true positive, true negative, false positive and false negative were subsequently evaluated for the meta-analysis. Results were pooled according to CT perfusion technique, namely snapshot techniques: single-phase rest, single-phase stress, single-phase dual-energy stress and combined coronary CT angiography [rest] and single-phase stress, as well the dynamic technique: dynamic stress CT perfusion. Twenty-two articles were included in the meta-analysis (1507 subjects). Pooled per-patient sensitivity and specificity of single-phase rest CT compared to rest SPECT were 89% (95% confidence interval [CI], 82-94%) and 88% (95% CI, 78-94%), respectively. Vessel-based sensitivity and specificity of single-phase stress CT compared to ICA-based >70% stenosis were 82% (95% CI, 64-92%) and 78% (95% CI, 61-89%). Segment-based sensitivity and specificity of single-phase dual-energy stress CT in comparison to stress MRI were 75% (95% CI, 60-85%) and 95% (95% CI, 80-99%). Segment-based sensitivity and specificity of dynamic stress CT perfusion compared to stress SPECT were 77% (95% CI, 67-85) and 89% (95% CI, 78-95%). For combined coronary CT angiography and single-phase stress CT, vessel-based sensitivity and specificity in comparison to ICA-based >50% stenosis were 84% (95% CI, 67-93%) and 93% (95% CI, 89-96%). This meta-analysis shows considerable variation in techniques and reference standards for CT of myocardial blood supply. While CT seems sensitive and specific for evaluation of hemodynamically relevant CAD, studies so far are limited in size. Standardization of myocardial perfusion CT technique is essential. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Lang, Steve; Tao, W.-K.; Simpson, J.; Ferrier, B.; Einaudi, Franco (Technical Monitor)
2001-01-01
Six different convective-stratiform separation techniques, including a new technique that utilizes the ratio of vertical and terminal velocities, are compared and evaluated using two-dimensional numerical simulations of a tropical [Tropical Ocean Global Atmosphere Coupled Ocean-Atmosphere Response Experiment (TOGA COARE)] and midlatitude continental [Preliminary Regional Experiment for STORM-Central (PRESTORM)] squall line. The simulations are made using two different numerical advection schemes: 4th order and positive definite advection. Comparisons are made in terms of rainfall, cloud coverage, mass fluxes, apparent heating and moistening, mean hydrometeor profiles, CFADs (Contoured Frequency with Altitude Diagrams), microphysics, and latent heating retrieval. Overall, it was found that the different separation techniques produced results that qualitatively agreed. However, the quantitative differences were significant. Observational comparisons were unable to conclusively evaluate the performance of the techniques. Latent heating retrieval was shown to be sensitive to the use of separation technique mainly due to the stratiform region for methods that found very little stratiform rain. The midlatitude PRESTORM simulation was found to be nearly invariant with respect to advection type for most quantities while for TOGA COARE fourth order advection produced numerous shallow convective cores and positive definite advection fewer cells that were both broader and deeper penetrating above the freezing level.
Detection of lipoarabinomannan as a diagnostic test for tuberculosis.
Sada, E; Aguilar, D; Torres, M; Herrera, T
1992-01-01
A coagglutination technique was established for the detection of lipoarabinomannan of Mycobacterium tuberculosis in human serum samples and evaluated for its utility in the diagnosis of tuberculosis at the Instituto Nacional de Enfermedades Respiratorias in Mexico City. The test had a sensitivity of 88% in patients with sputum-smear-positive active pulmonary tuberculosis. The sensitivity in patients with active pulmonary tuberculosis negative for acid-fast bacilli in sputum was 67%. Less favorable results were obtained for patients with AIDS and tuberculosis, with a sensitivity of 57%. The specificity in control patients with lung diseases different from tuberculosis and in healthy subjects was 100%. The positive predictive value was 100%, and the negative predictive value for patients with sputum-positive active pulmonary tuberculosis was 97%. The results of this study suggest that the detection of lipoarabinomannan is an accurate test for the diagnosis of pulmonary tuberculosis. PMID:1401008
NASA Astrophysics Data System (ADS)
Ketchazo, C.; Viale, T.; Boulade, O.; de la Barrière, F.; Dubreuil, D.; Mugnier, L.; Moreau, V.; Guérineau, N.; Mulet, P.; Druart, G.; Delisle, C.
2017-09-01
The intrapixel response is the signal detected by a single pixel illuminated by a Dirac distribution as a function of the position of this Dirac inside this pixel. It is also known as the pixel response function (PRF). This function measures the sensitivity variation at the subpixel scale and gives a spatial map of the sensitivity across a pixel.
NASA Astrophysics Data System (ADS)
Ikedo, Yuji; Fukuoka, Daisuke; Hara, Takeshi; Fujita, Hiroshi; Takada, Etsuo; Endo, Tokiko; Morita, Takako
2007-03-01
The comparison of left and right mammograms is a common technique used by radiologists for the detection and diagnosis of masses. In mammography, computer-aided detection (CAD) schemes using bilateral subtraction technique have been reported. However, in breast ultrasonography, there are no reports on CAD schemes using comparison of left and right breasts. In this study, we propose a scheme of false positive reduction based on bilateral subtraction technique in whole breast ultrasound images. Mass candidate regions are detected by using the information of edge directions. Bilateral breast images are registered with reference to the nipple positions and skin lines. A false positive region is detected based on a comparison of the average gray values of a mass candidate region and a region with the same position and same size as the candidate region in the contralateral breast. In evaluating the effectiveness of the false positive reduction method, three normal and three abnormal bilateral pairs of whole breast images were employed. These abnormal breasts included six masses larger than 5 mm in diameter. The sensitivity was 83% (5/6) with 13.8 (165/12) false positives per breast before applying the proposed reduction method. By applying the method, false positives were reduced to 4.5 (54/12) per breast without removing a true positive region. This preliminary study indicates that the bilateral subtraction technique is effective for improving the performance of a CAD scheme in whole breast ultrasound images.
Mathematical model of a DIC position sensing system within an optical trap
NASA Astrophysics Data System (ADS)
Wulff, Kurt D.; Cole, Daniel G.; Clark, Robert L.
2005-08-01
The quantitative study of displacements and forces of motor proteins and processes that occur at the microscopic level and below require a high level of sensitivity. For optical traps, two techniques for position sensing have been accepted and used quite extensively: quadrant photodiodes and an interferometric position sensing technique based on DIC imaging. While quadrant photodiodes have been studied in depth and mathematically characterized, a mathematical characterization of the interferometric position sensor has not been presented to the authors' knowledge. The interferometric position sensing method works off of the DIC imaging capabilities of a microscope. Circularly polarized light is sent into the microscope and the Wollaston prism used for DIC imaging splits the beam into its orthogonal components, displacing them by a set distance determined by the user. The distance between the axes of the beams is set so the beams overlap at the specimen plane and effectively share the trapped microsphere. A second prism then recombines the light beams and the exiting laser light's polarization is measured and related to position. In this paper we outline the mathematical characterization of a microsphere suspended in an optical trap using a DIC position sensing method. The sensitivity of this mathematical model is then compared to the QPD model. The mathematical model of a microsphere in an optical trap can serve as a calibration curve for an experimental setup.
Silim, A.; Elazhary, M.A.S.Y.
1983-01-01
Nasal epithelial cells were collected by cotton swabs for the diagnosis in experimental and field cases of infectious bovine rhinotracheitis and field cases of bovine viral diarrhea in calves. A portion of the cells was washed twice in phosphate buffered saline and a 25 µL drop was placed on microscope slides. The cells were dried, fixed and stained according to the direct fluorescent antibody technique. Another portion of the same specimen was inoculated onto primary bovine skin cell cultures for virus isolation. In the experimental studies for infectious bovine rhinotracheitis, 29/35 specimens were positive by fluorescent antibody technique and 32/35 by cell culture and in the field cases, 22/119 were positive by fluorescent antibody technique and 19/119 by cell culture. In the field cases of bovine viral diarrhea, 28/69 samples were positive by fluorescent antibody technique and 14/69 by cell culture. When fluorescent antibody technique was performed on inoculated cell cultures a total of 24/69 specimens were positive for bovine viral diarrhea. The sensitivity of fluorescent antibody technique was thus comparable to that of cell culture method for infectious bovine rhinotracheitis and bovine viral diarrhea. ImagesFig. 1.Fig. 2.Fig. 3. PMID:6299484
NASA Astrophysics Data System (ADS)
Habermann, T.; Didierjean, F.; Duchêne, G.; Filliger, M.; Gerl, J.; Kojouharov, I.; Li, G.; Pietralla, N.; Schaffner, H.; Sigward, M.-H.
2017-11-01
A device to characterize position-sensitive germanium detectors has been implemented at GSI. The main component of this so called scanning table is a gamma camera that is capable of producing online 2D images of the scanned detector by means of a PET technique. To calibrate the gamma camera Compton imaging is employed. The 2D data can be processed further offline to obtain depth information. Of main interest is the response of the scanned detector in terms of the digitized pulse shapes from the preamplifier. This is an important input for pulse-shape analysis algorithms as they are in use for gamma tracking arrays in gamma spectroscopy. To validate the scanning table, a comparison of its results with a second scanning table implemented at the IPHC Strasbourg is envisaged. For this purpose a pixelated germanium detector has been scanned.
Li, Kai; Rüdiger, Heinz; Haase, Rocco; Ziemssen, Tjalf
2018-01-01
Objective: As the multiple trigonometric regressive spectral (MTRS) analysis is extraordinary in its ability to analyze short local data segments down to 12 s, we wanted to evaluate the impact of the data segment settings by applying the technique of MTRS analysis for baroreflex sensitivity (BRS) estimation using a standardized data pool. Methods: Spectral and baroreflex analyses were performed on the EuroBaVar dataset (42 recordings, including lying and standing positions). For this analysis, the technique of MTRS was used. We used different global and local data segment lengths, and chose the global data segments from different positions. Three global data segments of 1 and 2 min and three local data segments of 12, 20, and 30 s were used in MTRS analysis for BRS. Results: All the BRS-values calculated on the three global data segments were highly correlated, both in the supine and standing positions; the different global data segments provided similar BRS estimations. When using different local data segments, all the BRS-values were also highly correlated. However, in the supine position, using short local data segments of 12 s overestimated BRS compared with those using 20 and 30 s. In the standing position, the BRS estimations using different local data segments were comparable. There was no proportional bias for the comparisons between different BRS estimations. Conclusion: We demonstrate that BRS estimation by the MTRS technique is stable when using different global data segments, and MTRS is extraordinary in its ability to evaluate BRS in even short local data segments (20 and 30 s). Because of the non-stationary character of most biosignals, the MTRS technique would be preferable for BRS analysis especially in conditions when only short stationary data segments are available or when dynamic changes of BRS should be monitored.
Milks, Maynard L; Sokolova, Yuliya Y; Isakova, Irina A; Fuxa, James R; Mitchell, Forrest; Snowden, Karen F; Vinson, S Bradleigh
2004-01-01
The main goal of this study was to compare the effectiveness of three staining techniques (calcofluor white M2R, Giemsa and modified trichrome), and the polymerase chain reaction (PCR) in detecting the microsporidium Thelohania solenopsae in red imported fire ants (Solenopsis invicta). The effect of the number of ants in a sample on the sensitivity of the staining techniques and the PCR, and the effect of three DNA extraction protocols on the sensitivity of PCR were also examined. In the first protocol, the ants were macerated and the crude homogenate was used immediately in the PCR. In the second protocol, the homogenate was placed on a special membrane (FTA card) that traps DNA, which is subsequently used in the PCR. In the third protocol, the DNA was purified from the homogenate by traditional phenol-chloroform extraction. Except for PCR using FTA cards, the sensitivity (number of samples positive for T. solenopsae) of all detection techniques increased with the number of ants in the sample. Overall, Giemsa was the least sensitive of all detection techniques. Calcofluor was more sensitive than modified trichrome with ants from one site and was equally as sensitive as PCR with crude DNA or a FTA card with ants from both sites. Trichrome staining was equally as sensitive as PCR with a FTA card at both sites, but it was less sensitive than PCR with crude DNA at one site. PCR on FTA cards was less sensitive than PCR with crude DNA for ants from one site but not the other. There was no difference whether crude or phenol-chloroform purified DNA was used as template. In summary, the results of this study show that PCR based on a crude DNA solution is equal to or more sensitive in detecting T. solenopsae than the other detection techniques investigated, and that it can be used as a reliable diagnostic tool for screening field samples of S. invicta for T. solenopsae. Nevertheless, ant smear stained with calcofluor or modified trichrome should be used to buttress findings from PCR.
Evaluation of mobile digital light-emitting diode fluorescence microscopy in Hanoi, Viet Nam.
Chaisson, L H; Reber, C; Phan, H; Switz, N; Nilsson, L M; Myers, F; Nhung, N V; Luu, L; Pham, T; Vu, C; Nguyen, H; Nguyen, A; Dinh, T; Nahid, P; Fletcher, D A; Cattamanchi, A
2015-09-01
Hanoi Lung Hospital, Hanoi, Viet Nam. To compare the accuracy of CellScopeTB, a manually operated mobile digital fluorescence microscope, with conventional microscopy techniques. Patients referred for sputum smear microscopy to the Hanoi Lung Hospital from May to September 2013 were included. Ziehl-Neelsen (ZN) smear microscopy, conventional light-emitting diode (LED) fluorescence microscopy (FM), CellScopeTB-based LED FM and Xpert(®) MTB/RIF were performed on sputum samples. The sensitivity and specificity of microscopy techniques were determined in reference to Xpert results, and differences were compared using McNemar's paired test of proportions. Of 326 patients enrolled, 93 (28.5%) were Xpert-positive for TB. The sensitivity of ZN microscopy, conventional LED FM, and CellScopeTB-based LED FM was respectively 37.6% (95%CI 27.8-48.3), 41.9% (95%CI 31.8-52.6), and 35.5% (95%CI 25.8-46.1). The sensitivity of CellScopeTB was similar to that of conventional LED FM (difference -6.5%, 95%CI -18.2 to 5.3, P = 0.33) and ZN microscopy (difference -2.2%, 95%CI -9.2 to 4.9, P = 0.73). The specificity was >99% for all three techniques. CellScopeTB performed similarly to conventional microscopy techniques in the hands of experienced TB microscopists. However, the sensitivity of all sputum microscopy techniques was low. Options enabled by digital microscopy, such as automated imaging with real-time computerized analysis, should be explored to increase sensitivity.
López, Lissett; Venteo, Angel; Aguirre, Enara; García, Marga; Rodríguez, Majosé; Amusátegui, Inmaculada; Tesouro, Miguel A; Vela, Carmen; Sainz, Angel; Rueda, Paloma
2007-11-01
An indirect enzyme-linked immunosorbent assay (ELISA) based on baculovirus recombinant P30 protein of Ehrlichia canis and the 1BH4 anticanine IgG monoclonal antibody was developed and evaluated by examining a panel of 98 positive and 157 negative sera using the indirect fluorescent antibody (IFA) test as the reference technique. The P30-based ELISA appeared to be sensitive and specific (77.55% and 95.54%, respectively) when qualitative results (positive/negative) were compared with those of the IFA test; the coefficient of correlation (R) between the 2 tests was 0.833. Furthermore, it was possible to establish a mathematical formula for use in comparing the results of both techniques. These results indicate that recombinant P30 antigen-based ELISA is a suitable alternative of the IFA test for simple, consistent, and rapid serodiagnosis of canine ehrlichiosis. Moreover, the use of this recombinant protein as antigen offers a great advantage for antigen preparation in comparison with other techniques in which the whole E. canis organism is used as antigen.
Optimizing the use of a skin prick test device on children.
Buyuktiryaki, Betul; Sahiner, Umit Murat; Karabulut, Erdem; Cavkaytar, Ozlem; Tuncer, Ayfer; Sekerel, Bulent Enis
2013-01-01
Studies comparing skin prick test (SPT) devices have revealed varying results in performance and there is little known about their use on children. We performed 2 complementary studies to test the sensitivity, reproducibility and acceptability of commercially available SPT devices (Stallerpoint, Antony, France) using different application techniques. In the first part, histamine/saline was put on as a drop by use of a vial (V), and in the second part it was transferred from a well with the aid of the test device (W). The techniques were as follows: apply vertical pressure (Stallerpoint-VP or Stallerpoint-WP), apply vertical pressure with 90° clockwise rotation (Stallerpoint-VC or Stallerpoint-WC) and apply vertical pressure with 90° clockwise and counter-clockwise rotations (Stallerpoint-VCC or Stallerpoint-WCC). For comparison, ALK Lancet was used with a technique of 'drop and apply vertical pressure'. In the first part, sensitivities of the Stallerpoint-VC (96.6%), Stallerpoint-VCC (95.5%) and ALK Lancet (93.2%) techniques were superior (p < 0.001) to the other Stallerpoint-VP and Stallerpoint-WP techniques (76.1 and 46.6%). Intrapatient coefficient of variation (CV) values were 15.0, 18.9, 15.4, 22.4 and 48.5%, respectively. Interpatient CV ranged between 22.8 and 55.1%. In the second part, the Stallerpoint-WC (98.8%), WCC (97.5%) and ALK Lancet (98.8%) techniques yielded high sensitivities, whereas the sensitivity of Stallerpoint-WP (28.7%) was very low. There were false-positive reactions in the Stallerpoint-VCC and WCC techniques. In children, the SPT technique was found to be as important as the testing device. Stallerpoint-VC and WC techniques are reliable, tolerable and comparable with the ALK Lancet technique. Copyright © 2013 S. Karger AG, Basel.
UTILIZATION OF CARBOHYDRATES AND POLYHYDRIC ALCOHOLS BY MYCOBACTERIUM TUBERCULOSIS
Sweeney, Edward E.; Jann, Gregory J.
1962-01-01
Sweeney, Edward E. (University of California, Los Angeles) and Gregory J. Jann. Utilization of carbohydrates and polyhydric alcohols by Mycobacterium tuberculosis. J. Bacteriol. 84:459–465. 1962.—A new procedure, using a massive inoculum and nongrowth basal medium, was employed for testing carbohydrate and polyhydric alcohol utilization by human tubercle bacilli. A positive reaction was represented by acidification of the test medium rather than by growth, which was the criterion for carbohydrate utilization in studies by earlier workers. The new procedure was both more sensitive and more rapid than growth techniques; results were obtained within days, compared to weeks or months required for growth testing. The massive-inoculum technique may be applied to compounds other than carbohydrates and polyhydric alcohols, and is a sensitive means of detecting changes wrought by various chemical and physical agents upon the metabolism of tubercle bacilli. Three H37Rv strains and six strains of human tubercle bacilli freshly isolated from patients were tested with 21 carbohydrates and polyhydric alcohols. All nine strains gave strong positive reactions for glucose and glycerol, and usually weak positive reactions for ribose and sorbose. Five of the nine strains were trehalose positive, and six (all fresh patient isolates) of the nine were mannose positive. PMID:13979661
Wang, Guorong; Guo, Ling; Jiang, Bin; Huang, Min; Zhang, Jian; Qin, Ying
2015-01-01
Amplitude changes in the P-wave of intracavitary electrocardiography have been used to assess the tip placement of central venous catheters. The research assessed the sensitivity and specificity of this sign in comparison with standard radiographic techniques for tip location, focusing on factors influencing its clinical utility. Both intracavitary electrocardiography guided tip location and X-ray positioning were used to verify catheter tip locations in patients undergoing central venous catheter insertion. Intracavitary electrocardiograms from 1119 patients (of a total 1160 subjects) showed specific amplitude changes in the P-wave. As the results show, compared with X-ray positioning, the sensitivity of electrocardiography-guided tip location was 97.3%, with false negative rate of 2.7%; the specificity was 1, with false positive rate of zero. Univariate analyses indicated that features including age, gender, height, body weight, and heart rate have no statistically significant influence on P-wave amplitude changes (P>0.05). Multivariate logistic regression revealed that catheter insertion routes (OR = 2.280, P = 0.003) and basal P-wave amplitude (OR = 0.553, P = 0.003) have statistically significant impacts on P-wave amplitude changes. As a reliable indicator of tip location, amplitude change in the P-wave has proved of good sensitivity and excellent specificity, and the minor, zero, false positive rate supports the clinical utility of this technique in early recognition of malpositioned tips. A better sensitivity was achieved in placement of centrally inserted central catheters (CICCs) than that of peripherally inserted central catheters (PICCs). In clinical practice, a combination of intracavitary electrocardiography, ultrasonic inspection and the anthropometric measurement method would further improve the accuracy. PMID:25915758
Hernández-Rodríguez, Patricia; Díaz, César A; Dalmau, Ernesto A; Quintero, Gladys M
2011-01-01
Leptospirosis is caused by Leptospira, gram negative spirochaetes whose microbiologic identification is difficult due to their low rate of growth and metabolic activity. In Colombia leptospirosis diagnosis is achieved by serological techniques without unified criteria for what positive titers are. In this study we compared polymerase chain reaction (PCR) with microbiological culture and dark field microscopy for the diagnosis of leptospirosis. Microbiological and molecular techniques were performed on 83 samples of urine taken from bovines in the savannahs surrounding Bogotá in Colombia, with presumptive diagnosis of leptospirosis. 117 samples of urine taken from healthy bovines were used as negative controls. 83 samples were MAT positive with titers ≥ 1:50; 81 with titers ≥ 1:100; and 66 with titers ≥ 1:200. 36% of the total samples (73/200) were Leptospira positives by microbiological culture, 32% (63/200) by dark field microscopy and 37% (74/200) by PCR. Amplicons obtained by PCR were 482 base pair long which are Leptospira specific. An amplicon of 262 base pairs typical of pathogenic Leptospira was observed in 71 out of the 74 PCR positive samples. The remaining 3 samples showed a 240 base pair amplicon which is typical of saprophytic Leptospira. PCR as a Leptospira diagnosis technique was 100% sensitive and 99% specific in comparison to microbiological culture. Kappa value of 0.99 indicated an excellent concordance between these techniques. Sensitivity and specificity reported for MAT when compared to microbiological culture was 0.95 and 0.89 with a ≥ 1:50 cut off. PCR was a reliable method for the rapid and precise diagnosis of leptospirosis when compared to traditional techniques in our study. The research presented here will be helpful to improve diagnosis and control of leptospirosis in Colombia and other endemic countries. Copyright © 2010 Elsevier B.V. All rights reserved.
Scaling images using their background ratio. An application in statistical comparisons of images.
Kalemis, A; Binnie, D; Bailey, D L; Flower, M A; Ott, R J
2003-06-07
Comparison of two medical images often requires image scaling as a pre-processing step. This is usually done with the scaling-to-the-mean or scaling-to-the-maximum techniques which, under certain circumstances, in quantitative applications may contribute a significant amount of bias. In this paper, we present a simple scaling method which assumes only that the most predominant values in the corresponding images belong to their background structure. The ratio of the two images to be compared is calculated and its frequency histogram is plotted. The scaling factor is given by the position of the peak in this histogram which belongs to the background structure. The method was tested against the traditional scaling-to-the-mean technique on simulated planar gamma-camera images which were compared using pixelwise statistical parametric tests. Both sensitivity and specificity for each condition were measured over a range of different contrasts and sizes of inhomogeneity for the two scaling techniques. The new method was found to preserve sensitivity in all cases while the traditional technique resulted in significant degradation of sensitivity in certain cases.
Jia, Li; Liu, Yaling; Du, Yanyan; Xing, Da
2007-06-22
A pressurized capillary electrochromatography (pCEC) system was developed for the separation of water-soluble vitamins, in which UV absorbance was used as the detection method and a monolithic silica-ODS column as the separation column. The parameters (type and content of organic solvent in the mobile phase, type and concentration of electrolyte, pH of the electrolyte buffer, applied voltage and flow rate) affecting the separation resolution were evaluated. The combination of two on-line concentration techniques, namely, solvent gradient zone sharpening effect and field-enhanced sample stacking, was utilized to improve detection sensitivity, which proved to be beneficial to enhance the detection sensitivity by enabling the injection of large volumes of samples. Coupling electrokinetic injection with the on-line concentration techniques was much more beneficial for the concentration of positively charged vitamins. Comparing with the conventional injection mode, the enhancement in the detection sensitivities of water-soluble vitamins using the on-line concentration technique is in the range of 3 to 35-fold. The developed pCEC method was applied to evaluate water-soluble vitamins in corns.
Detection of immunocytological markers in photomicroscopic images
NASA Astrophysics Data System (ADS)
Friedrich, David; zur Jacobsmühlen, Joschka; Braunschweig, Till; Bell, André; Chaisaowong, Kraisorn; Knüchel-Clarke, Ruth; Aach, Til
2012-03-01
Early detection of cervical cancer can be achieved through visual analysis of cell anomalies. The established PAP smear achieves a sensitivity of 50-90%, most false negative results are caused by mistakes in the preparation of the specimen or reader variability in the subjective, visual investigation. Since cervical cancer is caused by human papillomavirus (HPV), the detection of HPV-infected cells opens new perspectives for screening of precancerous abnormalities. Immunocytochemical preparation marks HPV-positive cells in brush smears of the cervix with high sensitivity and specificity. The goal of this work is the automated detection of all marker-positive cells in microscopic images of a sample slide stained with an immunocytochemical marker. A color separation technique is used to estimate the concentrations of the immunocytochemical marker stain as well as of the counterstain used to color the nuclei. Segmentation methods based on Otsu's threshold selection method and Mean Shift are adapted to the task of segmenting marker-positive cells and their nuclei. The best detection performance of single marker-positive cells was achieved with the adapted thresholding method with a sensitivity of 95.9%. The contours differed by a modified Hausdorff Distance (MHD) of 2.8 μm. Nuclei of single marker positive cells were detected with a sensitivity of 95.9% and MHD = 1.02 μm.
Assessing Breast Cancer Risk with an Artificial Neural Network
Sepandi, Mojtaba; Taghdir, Maryam; Rezaianzadeh, Abbas; Rahimikazerooni, Salar
2018-04-25
Objectives: Radiologists face uncertainty in making decisions based on their judgment of breast cancer risk. Artificial intelligence and machine learning techniques have been widely applied in detection/recognition of cancer. This study aimed to establish a model to aid radiologists in breast cancer risk estimation. This incorporated imaging methods and fine needle aspiration biopsy (FNAB) for cyto-pathological diagnosis. Methods: An artificial neural network (ANN) technique was used on a retrospectively collected dataset including mammographic results, risk factors, and clinical findings to accurately predict the probability of breast cancer in individual patients. Area under the receiver-operating characteristic curve (AUC), accuracy, sensitivity, specificity, and positive and negative predictive values were used to evaluate discriminative performance. Result: The network incorporating the selected features performed best (AUC = 0.955). Sensitivity and specificity of the ANN were respectively calculated as 0.82 and 0.90. In addition, negative and positive predictive values were respectively computed as 0.90 and 0.80. Conclusion: ANN has potential applications as a decision-support tool to help underperforming practitioners to improve the positive predictive value of biopsy recommendations. Creative Commons Attribution License
NASA Technical Reports Server (NTRS)
Dever, Timothy P.; Palazzolo, Alan B.; Thomas, Erwin M., III; Jansen, Ralph H.; McLallin, Kerry (Technical Monitor); Soeder, James (Technical Monitor)
2001-01-01
Eddy current position sensor performance is evaluated for use in a high-speed flywheel development system. The flywheel utilizes a five axis active magnetic bearing system. The eddy current sensors are used for position feedback for the bearing controller. Measured characteristics include sensitivity to multiple target materials and susceptibility to noise from the magnetic bearings and from sensor-to-sensor crosstalk. Improvements in axial sensor configuration and techniques for noise reduction are described.
Observational techniques for solar flare gamma-rays, hard X-rays, and neutrons
NASA Technical Reports Server (NTRS)
Lin, Robert P.
1989-01-01
The development of new instrumentation and techniques for solar hard X-ray, gamma ray and neutron observations from spacecraft and/or balloon-borne platforms is examined. The principal accomplishments are: (1) the development of a two segment germanium detector which is near ideal for solar hard X-ray and gamma ray spectroscopy; (2) the development of long duration balloon flight techniques and associated instrumentation; and (3) the development of innovative new position sensitive detectors for hard X-ray and gamma rays.
Precise orbit determination for NASA's earth observing system using GPS (Global Positioning System)
NASA Technical Reports Server (NTRS)
Williams, B. G.
1988-01-01
An application of a precision orbit determination technique for NASA's Earth Observing System (EOS) using the Global Positioning System (GPS) is described. This technique allows the geometric information from measurements of GPS carrier phase and P-code pseudo-range to be exploited while minimizing requirements for precision dynamical modeling. The method combines geometric and dynamic information to determine the spacecraft trajectory; the weight on the dynamic information is controlled by adjusting fictitious spacecraft accelerations in three dimensions which are treated as first order exponentially time correlated stochastic processes. By varying the time correlation and uncertainty of the stochastic accelerations, the technique can range from purely geometric to purely dynamic. Performance estimates for this technique as applied to the orbit geometry planned for the EOS platforms indicate that decimeter accuracies for EOS orbit position may be obtainable. The sensitivity of the predicted orbit uncertainties to model errors for station locations, nongravitational platform accelerations, and Earth gravity is also presented.
The influence of surface finishing methods on touch-sensitive reactions
NASA Astrophysics Data System (ADS)
Kukhta, M. S.; Sokolov, A. P.; Krauinsh, P. Y.; Kozlova, A. D.; Bouchard, C.
2017-02-01
This paper describes the modern technological development trends in jewelry design. In the jewelry industry, new trends, associated with the introduction of updated non-traditional materials and finishing techniques, are appearing. The existing information-oriented society enhances the visual aesthetics of new jewelry forms, decoration techniques (depth and surface), synthesis of different materials, which, all in all, reveal a bias towards positive effects of visual design. Today, the jewelry industry includes not only traditional techniques, but also such improved techniques as computer-assisted design, 3D-prototyping and other alternatives to produce an updated level of jewelry material processing. The authors present the specific features of ornamental pattern designing, decoration types (depth and surface) and comparative analysis of different approaches in surface finishing. Identifying the appearance or the effect of jewelry is based on proposed evaluation criteria, providing an advanced visual aesthetics basis is predicated on touch-sensitive responses.
Nanayakkara, P G C L; Dissanayaka, W L; Nanayakkara, B G; Amaratunga, E A P D; Tilakaratne, W M
2016-04-01
The use of oral cytology to diagnose malignant and premalignant lesions at an early stage is considered crucial. The aim of this study was to evaluate the diagnoses of the spatula and the cytobrush techniques compared with the gold standard histopathological findings, analysed according to different diagnostic criteria. Cytological smears were obtained from 76 suspicious oral malignant lesions and 116 oral leukoplakia lesions using two techniques: cytobrush plus cell collector and metal spatula. Subsequently, a surgical biopsy was performed on each lesion to achieve a histopathological diagnosis. Evaluation was conducted with respect to three different diagnostic criteria. The sensitivity for diagnosing carcinoma in clinically malignant cases was 89.58% and 60.42% for cytobrush and spatula techniques, respectively. Inclusion of severe dysplastic cases for 'high-risk' lesions increased the sensitivity up to 96.36% and 78.18% for two techniques, respectively. In leukoplakia lesions, malignant and severely dysplastic cells were diagnosed at a sensitivity of 88.89% in the cytobrush and 55.56% in the spatula techniques. Extending the criteria by defining malignant or any dysplastic findings as positive, sensitivity was increased to 98.02% and 89.11% for the spatula and the cytobrush techniques, respectively. Specificity for both techniques increased to 100%. The difference between the diagnoses of histopathology and the spatula cytology was statistically significant (P < 0.01), while no such difference was found with the cytobrush technique (P > 0.1). The cytobrush, unlike the spatula, is a useful screening instrument for early diagnosis of suspicious oral lesions and could therefore contribute to improved oral cancer prognosis. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Rapid and sensitive detection of enteroviruses in specimens from patients with aseptic meningitis.
Yerly, S; Gervaix, A; Simonet, V; Caflisch, M; Perrin, L; Wunderli, W
1996-01-01
A 5-h PCR assay (Amplicor enterovirus test) was compared with viral culture for the detection of enteroviruses in cerebrospinal fluid. Of the cerebrospinal fluid specimens collected during a summer outbreak of aseptic meningitis, 34% were positive by viral culture whereas 66% were positive by the Amplicor PCR, suggesting that this technique improves the diagnosis of enteroviral meningitis. PMID:8748304
A comparison of two neural network schemes for navigation
NASA Technical Reports Server (NTRS)
Munro, Paul W.
1989-01-01
Neural networks have been applied to tasks in several areas of artificial intelligence, including vision, speech, and language. Relatively little work has been done in the area of problem solving. Two approaches to path-finding are presented, both using neural network techniques. Both techniques require a training period. Training under the back propagation (BPL) method was accomplished by presenting representations of (current position, goal position) pairs as input and appropriate actions as output. The Hebbian/interactive activation (HIA) method uses the Hebbian rule to associate points that are nearby. A path to a goal is found by activating a representation of the goal in the network and processing until the current position is activated above some threshold level. BPL, using back-propagation learning, failed to learn, except in a very trivial fashion, that is equivalent to table lookup techniques. HIA, performed much better, and required storage of fewer weights. In drawing a comparison, it is important to note that back propagation techniques depend critically upon the forms of representation used, and can be sensitive to parameters in the simulations; hence the BPL technique may yet yield strong results.
A comparison of two neural network schemes for navigation
NASA Technical Reports Server (NTRS)
Munro, Paul
1990-01-01
Neural networks have been applied to tasks in several areas of artificial intelligence, including vision, speech, and language. Relatively little work has been done in the area of problem solving. Two approaches to path-finding are presented, both using neural network techniques. Both techniques require a training period. Training under the back propagation (BPL) method was accomplished by presenting representations of current position, goal position pairs as input and appropriate actions as output. The Hebbian/interactive activation (HIA) method uses the Hebbian rule to associate points that are nearby. A path to a goal is found by activating a representation of the goal in the network and processing until the current position is activated above some threshold level. BPL, using back-propagation learning, failed to learn, except in a very trivial fashion, that is equivalent to table lookup techniques. HIA, performed much better, and required storage of fewer weights. In drawing a comparison, it is important to note that back propagation techniques depend critically upon the forms of representation used, and can be sensitive to parameters in the simulations; hence the BPL technique may yet yield strong results.
A technique for position sensing and improved momentum evaluation of microparticle impacts in space.
NASA Technical Reports Server (NTRS)
Mcdonnell, J. A. M.; Abellanas, C.
1972-01-01
The design of a three element piezoelectric microparticle impact sensing diaphragm is described which is sensitive to the detection of momentum propagated by the bending wave. The design achieves a sensitivity of .03 microdyn/sec and optimizes the detection of the direct-path pulse from impact relative to secondary reflections and interference from discontinuities. Measurement of the relative arrival times and the maximum amplitudes of the outputs from the three piezoelectric sensors leads to the determination of the impact position and the normally resolved impact momentum exchange. Coincidence of the signals and a partial redundancy of data leads to a very high noise discrimination.
Braga, G W; Bordin, J O; Moreira Júnior, G; Kuroda, A
1998-01-01
The direct manual Polybrene test (DPT) and the direct antiglobulin tests (DAT) were employed to detect antibody sensitizing red blood cell (RCB) in patients with clinical and laboratorial findings of autoimmune hemolytic anemia (AIHA). To compare the sensitivity and specificity of DPT and DAT in the diagnosis of AIHA. Eighteen consecutive patients with diagnosis of AIHA were evaluated. The control group consisted of 20 normal volunteers blood donors and 20 patients with sickle cell anemia. All patients and controls were submitted to DPT and DAT. All DAT positive samples were further tested using monospecific reagents (anti-IgG heavy chain and anti-C3d). Positive samples for either DPT or DAT were evaluated by eluate technique using. The dichloromethane (DCM). The DAT was positive in 14 patients and negative in 4 subjects, while the DPT was positive in 17 patients and negative in 1 individual who had a positive DAT owing to complement (C3d). All positive eluates performed with DCM showed RBC autoantibodies with presumed "anti-Rh" specificity. The sensitivity rate of the DPT (94%) was significantly (p < 0.05) higher than the sensitivity rate of DAT (78%) to determine whether IgG was bound in vivo, but no difference was found regarding the specificity of the two tests. 1) The DPT is more sensitive than the DAT in detecting IgG autoantibody on the RBCs of patients with AIHA; 2) because of its simplicity and rapidity, the DPT is a useful additional screening test for the investigation of Coombs-negative AIHA.
Versatile analog pulse height computer performs real-time arithmetic operations
NASA Technical Reports Server (NTRS)
Brenner, R.; Strauss, M. G.
1967-01-01
Multipurpose analog pulse height computer performs real-time arithmetic operations on relatively fast pulses. This computer can be used for identification of charged particles, pulse shape discrimination, division of signals from position sensitive detectors, and other on-line data reduction techniques.
Hsu, Jia-Lien; Hung, Ping-Cheng; Lin, Hung-Yen; Hsieh, Chung-Ho
2015-04-01
Breast cancer is one of the most common cause of cancer mortality. Early detection through mammography screening could significantly reduce mortality from breast cancer. However, most of screening methods may consume large amount of resources. We propose a computational model, which is solely based on personal health information, for breast cancer risk assessment. Our model can be served as a pre-screening program in the low-cost setting. In our study, the data set, consisting of 3976 records, is collected from Taipei City Hospital starting from 2008.1.1 to 2008.12.31. Based on the dataset, we first apply the sampling techniques and dimension reduction method to preprocess the testing data. Then, we construct various kinds of classifiers (including basic classifiers, ensemble methods, and cost-sensitive methods) to predict the risk. The cost-sensitive method with random forest classifier is able to achieve recall (or sensitivity) as 100 %. At the recall of 100 %, the precision (positive predictive value, PPV), and specificity of cost-sensitive method with random forest classifier was 2.9 % and 14.87 %, respectively. In our study, we build a breast cancer risk assessment model by using the data mining techniques. Our model has the potential to be served as an assisting tool in the breast cancer screening.
2013-01-01
Background Our aim was to develop a new protocol for MGMT immunohistochemistry with good agreement between observers and good correlation with molecular genetic tests of tumour methylation. We examined 40 primary brain tumours (30 glioblastomas and 10 oligodendroglial tumours) with our new technique, namely double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumour antigens (CD34, CD45 and CD68). We compared the results with single-labelling immunohistochemistry for MGMT and methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA, a recognised molecular genetic technique which we applied as the gold-standard for the methylation status). Results Double-labelling immunohistochemistry for MGMT produced a visual separation of tumourous and non-tumourous elements on the same histological slide, making it quick and easy to determine whether tumour cell nuclei were MGMT-positive or MGMT-negative (and thereby infer the methylation status of the tumour). We found good agreement between observers (kappa 0.76) and within observer (kappa 0.84). Furthermore, double-labelling showed good specificity (80%), sensitivity (73.33%), positive predictive value (PPV, 83.33%) and negative predictive value (NPV, 68.75%) compared to MS-MLPA. Double-labelling was quicker and easier to assess than single-labelling and it outperformed quantitative computerised image analysis of MGMT single-labelling in terms of sensitivity, specificity, PPV and NPV. Conclusions Double-labelling immunohistochemistry for MGMT and a cocktail of non-tumourous elements provides a "one look" method for determining whether tumour cell nuclei are MGMT-positive or MGMT-negative. This can be used to infer the methylation status of the tumour. There is good observer agreement and good specificity, sensitivity, PPV and NPV compared to a molecular gold-standard. PMID:24252243
Burke, Elinor; Grobler, Mariana; Elderfield, Kay; Bond, Frances; Crocker, Matthew; Taylor, Rohan; Bridges, Leslie R
2013-06-10
Our aim was to develop a new protocol for MGMT immunohistochemistry with good agreement between observers and good correlation with molecular genetic tests of tumour methylation. We examined 40 primary brain tumours (30 glioblastomas and 10 oligodendroglial tumours) with our new technique, namely double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumour antigens (CD34, CD45 and CD68). We compared the results with single-labelling immunohistochemistry for MGMT and methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA, a recognised molecular genetic technique which we applied as the gold-standard for the methylation status). Double-labelling immunohistochemistry for MGMT produced a visual separation of tumourous and non-tumourous elements on the same histological slide, making it quick and easy to determine whether tumour cell nuclei were MGMT-positive or MGMT-negative (and thereby infer the methylation status of the tumour). We found good agreement between observers (kappa 0.76) and within observer (kappa 0.84). Furthermore, double-labelling showed good specificity (80%), sensitivity (73.33%), positive predictive value (PPV, 83.33%) and negative predictive value (NPV, 68.75%) compared to MS-MLPA. Double-labelling was quicker and easier to assess than single-labelling and it outperformed quantitative computerised image analysis of MGMT single-labelling in terms of sensitivity, specificity, PPV and NPV. Double-labelling immunohistochemistry for MGMT and a cocktail of non-tumourous elements provides a "one look" method for determining whether tumour cell nuclei are MGMT-positive or MGMT-negative. This can be used to infer the methylation status of the tumour. There is good observer agreement and good specificity, sensitivity, PPV and NPV compared to a molecular gold-standard.
High speed curved position sensitive detector
Hendricks, Robert W.; Wilson, Jack W.
1989-01-01
A high speed curved position sensitive porportional counter detector for use in x-ray diffraction, the detection of 5-20 keV photons and the like. The detector employs a planar anode assembly of a plurality of parallel metallic wires. This anode assembly is supported between two cathode planes, with at least one of these cathode planes having a serpentine resistive path in the form of a meander having legs generally perpendicular to the anode wires. This meander is produced by special microelectronic fabrication techniques whereby the meander "wire" fans outwardly at the cathode ends to produce the curved aspect of the detector, and the legs of the meander are small in cross-section and very closely spaced whereby a spatial resolution of about 50 .mu.m can be achieved. All of the other performance characteristics are about as good or better than conventional position sensitive proportional counter type detectors. Count rates of up to 40,000 counts per second with 0.5 .mu.s shaping time constants are achieved.
Being present at school: implementing mindfulness in schools.
Bostic, Jeff Q; Nevarez, Michael D; Potter, Mona P; Prince, Jefferson B; Benningfield, Margaret M; Aguirre, Blaise A
2015-04-01
Developmentally sensitive efforts to help students learn, practice, and regularly use mindfulness tactics easily and readily in and beyond the classroom are important to help them manage future stresses. Mindfulness emphasizes consciously focusing the mind in the present moment, purposefully, without judgment or attachment. Meditation extends this to setting aside time and places to practice mindfulness, and additionally, yoga includes physical postures and breathing techniques that enhance mindfulness and meditation. Several mindfulness programs and techniques have been applied in schools, with positive benefits reported. Some elements of these programs require modifications to be sensitive to the developmental state of the children receiving mindfulness training. Copyright © 2015 Elsevier Inc. All rights reserved.
OARSI Clinical Trials Recommendations for Hip Imaging in Osteoarthritis
Gold, Garry E.; Cicuttini, Flavia; Crema, Michel D.; Eckstein, Felix; Guermazi, Ali; Kijowski, Richard; Link, Thomas M.; Maheu, Emmanuel; Martel-Pelletier, Johanne; Miller, Colin G.; Pelletier, Jean-Pierre; Peterfy, Charles G.; Potter, Hollis G.; Roemer, Frank W.; Hunter, David. J
2015-01-01
Imaging of hip in osteoarthritis (OA) has seen considerable progress in the past decade, with the introduction of new techniques that may be more sensitive to structural disease changes. The purpose of this expert opinion, consensus driven recommendation is to provide detail on how to apply hip imaging in disease modifying clinical trials. It includes information on acquisition methods/ techniques (including guidance on positioning for radiography, sequence/protocol recommendations/ hardware for MRI); commonly encountered problems (including positioning, hardware and coil failures, artifacts associated with various MRI sequences); quality assurance/ control procedures; measurement methods; measurement performance (reliability, responsiveness, and validity); recommendations for trials; and research recommendations. PMID:25952344
Patent foramen ovale: comparison among diagnostic strategies in cryptogenic stroke and migraine.
Zito, Concetta; Dattilo, Giuseppe; Oreto, Giuseppe; Di Bella, Gianluca; Lamari, Annalisa; Iudicello, Raffaella; Trio, Olimpia; Caracciolo, Giuseppe; Coglitore, Sebastiano; Arrigo, Francesco; Carerj, Scipione
2009-05-01
The aim of this study was to compare transthoracic echocardiography (TTE) and transcranial Doppler ultrasonography (TCD) with transesophageal echocardiography (TEE) in order to define the best clinical approach to patent foramen ovale (PFO) detection. In total, 72 consecutive patients (33 men) with a mean age of 49 +/- 13 years were prospectively enrolled. The TEE indication was cryptogenic stroke (36 patients) or migraine (36 patients, 22 with aura). All patients underwent standard TTE, TCD, and TEE examination. For any study, a contrast test was carried on using an agitated saline solution mixed with urea-linked gelatine (Haemaccel), injected as a rapid bolus via a right antecubital vein. A prolonged Valsalva maneuver was performed to improve test sensitivity. TEE identified a PFO in 65% of the whole population: 56.5% in the migraine cohort and 43.5% in the cryptogenic stroke cohort. TTE was able to detect a PFO in 55% of patients positive at TEE (54% negative predictive value, 100% positive predictive value, 55% sensitivity, and 100% specificity). TCD was able to identify a PFO in 97% of patients positive at TEE (89% negative predictive value, 98% positive predictive value, 94% sensitivity, and 96% specificity). In patients with cryptogenic stroke and migraine, there is a fair concordance (k = 0.89) between TCD and TEE in PFO recognition. Accordingly, TCD should be recommended as a simple, noninvasive, and reliable technique, whereas TEE indication should be restricted to selected patients. TTE is a very specific technique, whose major advantage is the ability to detect a large right-to-left shunt, particularly if associated with an atrial septal aneurysm.
Gorgievski-Hrisoho, Meri; Schumacher, Jean-Daniel; Vilimonovic, Nevenka; Germann, Daniel; Matter, Lukas
1998-01-01
Enteroviruses (EV) are among the most common causes of aseptic meningitis. Standard diagnostic techniques are often too slow and lack sensitivity to be of clinical relevance. EV RNA can be detected within 5 h by a commercially available reverse transcription-PCR (RT-PCR) test kit. Cerebrospinal fluid (CSF) samples from 68 patients presenting with aseptic meningitis during a summer outbreak in Switzerland were examined in parallel with cell culture and commercial RT-PCR. RT-PCR was positive in all 16 CSF specimens positive by cell culture (100%). In addition, 42 of 52 (80%) CSF samples negative by cell culture were PCR positive. In 26 of these 42 (62%) patients, viral culture from other sites (throat swab or stool) was also positive. The CSF virus culture took 3 to 7 days to become positive. Echovirus 30 was the type most often isolated in this outbreak. The sensitivity of CSF RT-PCR based on clinical diagnosis during this aseptic meningitis outbreak in patients with negative bacterial culture results was 85%, i.e., considerably higher than the sensitivity of CSF virus culture (24%). We conclude that this commercial RT-PCR assay allows a positive diagnosis with minimal delay and may thus influence clinical decisions. PMID:9705364
Origin of the Ultrafast Response of the Lateral Photovoltaic Effect in Amorphous MoS2/Si Junctions.
Hu, Chang; Wang, Xianjie; Miao, Peng; Zhang, Lingli; Song, Bingqian; Liu, Weilong; Lv, Zhe; Zhang, Yu; Sui, Yu; Tang, Jinke; Yang, Yanqiang; Song, Bo; Xu, Ping
2017-05-31
The lateral photovoltaic (LPV) effect has attracted much attention for a long time because of its application in position-sensitive detectors (PSD). Here, we report the ultrafast response of the LPV in amorphous MoS 2 /Si (a-MoS 2 /Si) junctions prepared by the pulsed laser deposition (PLD) technique. Different orientations of the built-in field and the breakover voltages are observed for a-MoS 2 films deposited on p- and n-type Si wafers, resulting in the induction of positive and negative voltages in the a-MoS 2 /n-Si and a-MoS 2 /p-Si junctions upon laser illumination, respectively. The dependence of the LPV on the position of the illumination shows very high sensitivity (183 mV mm -1 ) and good linearity. The optical relaxation time of LPV with a positive voltage was about 5.8 μs in a-MoS 2 /n-Si junction, whereas the optical relaxation time of LPV with a negative voltage was about 2.1 μs in a-MoS 2 /p-Si junction. Our results clearly suggested that the inversion layer at the a-MoS 2 /Si interface made a good contribution to the ultrafast response of the LPV in a-MoS 2 /Si junctions. The large positional sensitivity and ultrafast relaxation of LPV may promise the a-MoS 2 /Si junction's applications in fast position-sensitive detectors.
Parodi, S; Balbi, C; Taningher, M; Pala, M; Russo, P; Abelmoschi, M L; Santi, L
1982-11-01
DNA damage induced in vivo by 3'-methyl-4-dimethylaminoazobenzene (3'CH3DAB) was investigated with 2 differently sensitive techniques: the alkaline elution assay and the viscometric measurement of DNA damage. 3'CH3DAB appeared to be falsely negative with the alkaline elution assay, whereas with the viscometric approach, which is about 30-50 times more sensitive, it appeared positive, and the DNA damage was dose-dependent.
Mini gamma camera, camera system and method of use
Majewski, Stanislaw; Weisenberger, Andrew G.; Wojcik, Randolph F.
2001-01-01
A gamma camera comprising essentially and in order from the front outer or gamma ray impinging surface: 1) a collimator, 2) a scintillator layer, 3) a light guide, 4) an array of position sensitive, high resolution photomultiplier tubes, and 5) printed circuitry for receipt of the output of the photomultipliers. There is also described, a system wherein the output supplied by the high resolution, position sensitive photomultipiler tubes is communicated to: a) a digitizer and b) a computer where it is processed using advanced image processing techniques and a specific algorithm to calculate the center of gravity of any abnormality observed during imaging, and c) optional image display and telecommunications ports.
Laser beam soldering of micro-optical components
NASA Astrophysics Data System (ADS)
Eberhardt, R.
2003-05-01
MOTIVATION Ongoing miniaturisation and higher requirements within optical assemblies and the processing of temperature sensitive components demands for innovative selective joining techniques. So far adhesive bonding has primarily been used to assemble and adjust hybrid micro optical systems. However, the properties of the organic polymers used for the adhesives limit the application of these systems. In fields of telecommunication and lithography, an enhancement of existing joining techniques is necessary to improve properties like humidity resistance, laserstability, UV-stability, thermal cycle reliability and life time reliability. Against this background laser beam soldering of optical components is a reasonable joining technology alternative. Properties like: - time and area restricted energy input - energy input can be controlled by the process temperature - direct and indirect heating of the components is possible - no mechanical contact between joining tool and components give good conditions to meet the requirements on a joining technology for sensitive optical components. Additionally to the laser soldering head, for the assembly of optical components it is necessary to include positioning units to adjust the position of the components with high accuracy before joining. Furthermore, suitable measurement methods to characterize the soldered assemblies (for instance in terms of position tolerances) need to be developed.
Fornazari, Felipe; da Silva, Rodrigo Costa; Richini-Pereira, Virginia Bodelão; Beserra, Hugo Enrique Orsini; Luvizotto, Maria Cecília Rui; Langoni, Helio
2012-09-01
Leptospirosis is an infectious disease of worldwide importance. The development of diagnostic techniques allows sick animals to be identified, reservoirs to be eliminated and the disease prevented and controlled. The present study aimed to compare different techniques for diagnosing leptospirosis in sheep. Samples of kidney, liver and blood were collected from 465 animals that originated from a slaughterhouse. The sera were analyzed by the Microscopic Agglutination Test (MAT), and kidney and liver samples of seropositive animals were analyzed using four techniques: bacteriological culture, the Warthin Starry (WS) technique, conventional PCR (cPCR), and quantitative PCR (qPCR). With the MAT, 21 animals were positive (4.5%) to serovars Hardjo (n=12), Hebdomadis (n=5), Sentot (n=2), Wolfii (n=1) and Shermani (n=1). Titers were 100 (n=10), 200 (n=2), 400 (n=6) and 1600 (n=3). No animal was positive by bacteriological culture; four animals were positive by the WS technique in kidney samples; six animals were positive by cPCR in kidney samples; and 11 animals were positive by qPCR, eight of which in kidney samples and three in liver. The bacterial quantification revealed a median of 4.3 bacteria/μL in liver samples and 36.6 bacteria/μL in kidney samples. qPCR presented the highest sensitivity among the techniques, followed by cPCR, the WS technique and bacteriological culture. These results indicate that sheep can carry leptospires of the Sejroe serogroup, and demonstrate the efficiency of quantitative PCR to detect Leptospira spp. in tissue samples. Published by Elsevier B.V.
Centelleghe, Cinzia; Beffagna, Giorgia; Zanetti, Rossella; Zappulli, Valentina; Di Guardo, Giovanni; Mazzariol, Sandro
2016-09-01
Cetacean Morbillivirus (CeMV) has been identified as the most pathogenic virus for cetaceans. Over the past three decades, this RNA virus has caused several outbreaks of lethal disease in odontocetes and mysticetes worldwide. Isolation and identification of CeMV RNA is very challenging in whales because of the poor preservation status frequently shown by tissues from stranded animals. Nested reverse transcription polymerase chain reaction (nested RT-PCR) is used instead of conventional RT-PCR when it is necessary to increase the sensitivity and the specificity of the reaction. This study describes a new nested RT-PCR technique useful to amplify small amounts of the cDNA copy of Cetacean morbillivirus (CeMV) when it is present in scant quantity in whales' biological specimens. This technique was used to analyze different tissues (lung, brain, spleen and other lymphoid tissues) from one under human care seal and seven cetaceans stranded along the Italian coastline between October 2011 and September 2015. A well-characterized, 200 base pair (bp) fragment of the dolphin Morbillivirus (DMV) haemagglutinin (H) gene, obtained by nested RT-PCR, was sequenced and used to confirm DMV positivity in all the eight marine mammals under study. In conclusion, this nested RT-PCR protocol can represent a sensitive detection method to identify CeMV-positive, poorly preserved tissue samples. Furthermore, this is also a rather inexpensive molecular technique, relatively easy to apply. Copyright © 2016 Elsevier B.V. All rights reserved.
Reina, J; Weber, I; Riera, E; Busquets, M; Morales, C
2014-05-01
Cytomegalovirus (CMV) is the main virus causing congenital and postnatal infections in the pediatric population. The aim of this study is to evaluate the usefulness of a quantitative real-time PCR in the diagnosis of these infections using urine as a single sample. We studied all the urine samples of newborns (< 7 days) with suspected congenital infection, and urine of patients with suspected postnatal infection (urine negative at birth). Urines were simultaneously studied by cell culture, qualitative PCR (PCRc), and quantitative real-time PCR (PCRq). We analyzed 332 urine samples (270 to rule out congenital infection and 62 postnatal infections). Of the first, 22 were positive in the PCRq, 19 in the PCRc, and 17 in the culture. PCRq had a sensitivity of 100%, on comparing the culture with the rest of the techniques. Using the PCRq as a reference method, culture had a sensitivity of 77.2%, and PCRc 86.3%. In cases of postnatal infection, PCRq detected 16 positive urines, the PCRq 12, and the cell culture 10. The urines showed viral loads ranging from 2,178 to 116,641 copies/ml. The genomic amplification technique PCRq in real time was more sensitive than the other techniques evaluated. This technique should be considered as a reference (gold standard), leaving the cell culture as a second diagnostic level. The low cost and the automation of PCRq would enable the screening for CMV infection in large neonatal and postnatal populations. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Importance of sample preparation for molecular diagnosis of lyme borreliosis from urine.
Bergmann, A R; Schmidt, B L; Derler, A-M; Aberer, E
2002-12-01
Urine PCR has been used for the diagnosis of Borrelia burgdorferi infection in recent years but has been abandoned because of its low sensitivity and the irreproducibility of the results. Our study aimed to analyze technical details related to sample preparation and detection methods. Crucial for a successful urine PCR were (i) avoidance of the first morning urine sample; (ii) centrifugation at 36,000 x g; and (iii) the extraction method, with only DNAzol of the seven different extraction methods used yielding positive results with patient urine specimens. Furthermore, storage of frozen urine samples at -80 degrees C reduced the sensitivity of a positive urine PCR result obtained with samples from 72 untreated erythema migrans (EM) patients from 85% in the first 3 months to <30% after more than 3 months. Bands were detected at 276 bp on ethidium bromide-stained agarose gels after amplification by a nested PCR. The specificity of bands for 32 of 33 samples was proven by hybridization with a GEN-ETI-K-DEIA kit and for a 10 further positive amplicons by sequencing. By using all of these steps to optimize the urine PCR technique, B. burgdorferi infection could be diagnosed by using urine samples from EM patients with a sensitivity (85%) substantially better than that of serological methods (50%). This improved method could be of future importance as an additional laboratory technique for the diagnosis of unclear, unrecognized borrelia infections and diseases possibly related to Lyme borreliosis.
A novel pulse height analysis technique for nuclear spectroscopic and imaging systems
NASA Astrophysics Data System (ADS)
Tseng, H. H.; Wang, C. Y.; Chou, H. P.
2005-08-01
The proposed pulse height analysis technique is based on the constant and linear relationship between pulse width and pulse height generated from front-end electronics of nuclear spectroscopic and imaging systems. The present technique has successfully implemented into the sump water radiation monitoring system in a nuclear power plant. The radiation monitoring system uses a NaI(Tl) scintillator to detect radioactive nuclides of Radon daughters brought down by rain. The technique is also used for a nuclear medical imaging system. The system uses a position sensitive photomultiplier tube coupled with a scintillator. The proposed techniques has greatly simplified the electronic design and made the system a feasible one for potable applications.
Methods and systems for remote detection of gases
Johnson, Timothy J.
2007-11-27
Novel systems and methods for remotely detecting at least one constituent of a gas via infrared detection are provided. A system includes at least one extended source of broadband infrared radiation and a spectrally sensitive receiver positioned remotely from the source. The source and the receiver are oriented such that a surface of the source is in the field of view of the receiver. The source includes a heating component thermally coupled to the surface, and the heating component is configured to heat the surface to a temperature above ambient temperature. The receiver is operable to collect spectral infrared absorption data representative of a gas present between the source and the receiver. The invention advantageously overcomes significant difficulties associated with active infrared detection techniques known in the art, and provides an infrared detection technique with a much greater sensitivity than passive infrared detection techniques known in the art.
Methods and systems for remote detection of gases
Johnson, Timothy J
2012-09-18
Novel systems and methods for remotely detecting at least one constituent of a gas via infrared detection are provided. A system includes at least one extended source of broadband infrared radiation and a spectrally sensitive receiver positioned remotely from the source. The source and the receiver are oriented such that a surface of the source is in the field of view of the receiver. The source includes a heating component thermally coupled to the surface, and the heating component is configured to heat the surface to a temperature above ambient temperature. The receiver is operable to collect spectral infrared absorption data representative of a gas present between the source and the receiver. The invention advantageously overcomes significant difficulties associated with active infrared detection techniques known in the art, and provides an infrared detection technique with a much greater sensitivity than passive infrared detection techniques known in the art.
Biance-Valero, E; De Laval, F; Delerue, M; Savini, H; Cheinin, S; Leroy, P; Soullié, B
2013-05-01
The authors report the results of molecular biology techniques for the early diagnosis of cases (invasion phase) of schistosomiasis during two epidemics occurring during French military projects in the Central African Republic and Madagascar. The use of these techniques in real time for subjects not residing in the endemic area significantly improves the sensitivity of screening. The attack rates of these episodes, according to a case definition that took positive specific PCR results into account, were 59% and 26%. These results are a concrete illustration of the proverb that "yaws begin where the trail stops".
Flori, Pierre; Delaunay, Edouard; Guillerme, Cécile; Charaoui, Sana; Raberin, Hélène; Hafid, Jamal; L'Ollivier, Coralie
2017-01-01
ABSTRACT A study comparing the ICT (immunochromatography technology) Toxoplasma IgG and IgM rapid diagnostic test (LDBio Diagnostics, France) with a fully automated system, Architect, was performed on samples from university hospitals of Marseille and Saint-Etienne. A total of 767 prospective sera and 235 selected sera were collected. The panels were selected to test various IgG and IgM parameters. The reference technique, Toxoplasma IgGII Western blot analysis (LDBio Diagnostics), was used to confirm the IgG results, and commercial kits Platelia Toxo IgM (Bio-Rad) and Toxo-ISAgA (bioMérieux) were used in Saint-Etienne and Marseille, respectively, as the IgM reference techniques. Sensitivity and specificity of the ICT and the Architect IgG assays were compared using a prospective panel. Sensitivity was 100% for the ICT test and 92.1% for Architect (cutoff at 1.6 IU/ml). The low-IgG-titer serum results confirmed that ICT sensitivity was superior to that of Architect. Specificity was 98.7% (ICT) and 99.8% (Architect IgG). The ICT test is also useful for detecting IgM without IgG and is both sensitive (100%) and specific (100%), as it can distinguish nonspecific IgM from specific Toxoplasma IgM. In comparison, IgM sensitivity and specificity on Architect are 96.1% and 99.6%, respectively (cutoff at 0.5 arbitrary units [AU]/ml). To conclude, this new test overcomes the limitations of automated screening techniques, which are not sensitive enough for IgG and lack specificity for IgM (rare IgM false-positive cases). PMID:28954897
Wilcoxon signed-rank-based technique for the pulse-shape analysis of HPGe detectors
NASA Astrophysics Data System (ADS)
Martín, S.; Quintana, B.; Barrientos, D.
2016-07-01
The characterization of the electric response of segmented-contact high-purity germanium detectors requires scanning systems capable of accurately associating each pulse with the position of the interaction that generated it. This process requires an algorithm sensitive to changes above the electronic noise in the pulse shapes produced at different positions, depending on the resolution of the Ge crystal. In this work, a pulse-shape comparison technique based on the Wilcoxon signed-rank test has been developed. It provides a method to distinguish pulses coming from different interaction points in the germanium crystal. Therefore, this technique is a necessary step for building a reliable pulse-shape database that can be used later for the determination of the position of interaction for γ-ray tracking spectrometry devices such as AGATA, GRETA or GERDA. The method was validated by comparison with a χ2 test using simulated and experimental pulses corresponding to a Broad Energy germanium detector (BEGe).
Development of a superconducting position sensor for the Satellite Test of the Equivalence Principle
NASA Astrophysics Data System (ADS)
Clavier, Odile Helene
The Satellite Test of the Equivalence Principle (STEP) is a joint NASA/ESA mission that proposes to measure the differential acceleration of two cylindrical test masses orbiting the earth in a drag-free satellite to a precision of 10-18 g. Such an experiment would conceptually reproduce Galileo's tower of Pisa experiment with a much longer time of fall and greatly reduced disturbances. The superconducting test masses are constrained in all degrees of freedom except their axial direction (the sensitive axis) using superconducting bearings. The STEP accelerometer measures the differential position of the masses in their sensitive direction using superconducting inductive pickup coils coupled to an extremely sensitive magnetometer called a DC-SQUID (Superconducting Quantum Interference Device). Position sensor development involves the design, manufacture and calibration of pickup coils that will meet the acceleration sensitivity requirement. Acceleration sensitivity depends on both the displacement sensitivity and stiffness of the position sensor. The stiffness must kept small while maintaining stability of the accelerometer. Using a model for the inductance of the pickup coils versus displacement of the test masses, a computer simulation calculates the sensitivity and stiffness of the accelerometer in its axial direction. This simulation produced a design of pickup coils for the four STEP accelerometers. Manufacture of the pickup coils involves standard photolithography techniques modified for superconducting thin-films. A single-turn pickup coil was manufactured and produced a successful superconducting coil using thin-film Niobium. A low-temperature apparatus was developed with a precision position sensor to measure the displacement of a superconducting plate (acting as a mock test mass) facing the coil. The position sensor was designed to detect five degrees of freedom so that coupling could be taken into account when measuring the translation of the plate relative to the coil. The inductance was measured using a DC-SQUID coupled to the pickup coil. The experimental results agree with the model used in the simulation thereby validating the concept used for the design. The STEP program now has the confidence necessary to design and manufacture a position sensor for the flight accelerometer.
A technique for using radio jets as extended gravitational lensing probes
NASA Technical Reports Server (NTRS)
Kronberg, Philipp P.; Dyer, Charles C.; Burbidge, E. Margaret; Junkkarinen, Vesa T.
1991-01-01
A new and potentially powerful method of measuring the mass of a galaxy (or dark matter concentration) which lies close in position to a background polarized radio jet is proposed. Using the fact that the polarization angle is not changed by lensing, an 'alignment-breaking parameter' is defined which is a sensitive indicator of gravitational distortion. The method remains sensitive over a wide redshift range of the gravitational lens. This technique is applied to the analysis of polarimetric observations of the jet of 3C 9 at z = 2.012, combined with a newly discovered 20.3 mag foreground galaxy at z = 0.2538 to 'weigh' the galaxy and obtain an approximate upper limit to the mass-to-light ratio.
Diagnosis of herpes simplex virus infection by immunofluorescence.
Taber, L H; Brasier, F; Couch, R B; Greenberg, S B; Jones, D; Knight, V
1976-01-01
The utility of the indirect immunofluorescent antibody (IFA) technique for diagnosis of herpes simplex virus (HSV) infection was examined by testing specimens for this agent from 31 patients with encephalitis or meningitis, 17 with conjunctivitis, 19 with genital disease, and 1 with genital disease and meningitis. Brain biopsy tissue from four patients with encephalitis was positive by IFA and virus culture for HSV. Leukocytes in cerebrospinal fluid from these four patients and one with HSV meningitis were also positive by IFA, but virus isolation attempts on the fluid were all negative. Conjunctival scrapings from two patients with conjunctivitis were positive for HSV by both IFA and virus culture. Eleven of 12 culture-positive lesions of herpes progenitalis were positive by IFA, and 1 dark field-positive syphilitic chancre was also positive for HSV by both IFA and culture. Evidence for specificity of the results was provided by internal controls in each test and negative results from patients with other diagnoses. Thus, the IFA technique constituted a rapid, sensitive, and specific diagnostic method for the diagnosis of HSV infections. PMID:178689
Utility of PCR in diagnosing pulmonary tuberculosis.
Bennedsen, J; Thomsen, V O; Pfyffer, G E; Funke, G; Feldmann, K; Beneke, A; Jenkins, P A; Hegginbothom, M; Fahr, A; Hengstler, M; Cleator, G; Klapper, P; Wilkins, E G
1996-06-01
At present, the rapid diagnosis of pulmonary tuberculosis rests with microscopy. However, this technique is insensitive and many cases of pulmonary tuberculosis cannot be initially confirmed. Nucleic acid amplification techniques are extremely sensitive, but when they are applied to tuberculosis diagnosis, they have given variable results. Investigators at six centers in Europe compared a standardized PCR system (Amplicor; Roche) against conventional culture methods. Defined clinical information was collected. Discrepant samples were retested, and inhibition assays and backup amplification with a separate primer pair were performed. Mycobacterium tuberculosis complex organisms were recovered from 654 (9.1%) of 7,194 samples and 293 (7.8%) of 3,738 patients. Four hundred fifty-two of the M. tuberculosis isolates from 204 patients were smear positive and culture positive. Among the culture-positive specimens, PCR had a sensitivity of 91.4% for smear-positive specimens and 60.9% for smear-negative specimens, with a specificity of 96.1%. Analysis of 254 PCR-positive, culture-negative specimens with discrepant results revealed that 130 were from patients with recently diagnosed tuberculosis and 94 represented a presumed laboratory error. Similar analysis of 118 PCR-negative, culture-positive specimens demonstrated that 27 discrepancies were due to presumed uneven aliquot distribution and 11 were due to presumed laboratory error; PCR inhibitors were detected in 8 specimens. Amplicor enables laboratories with little previous experience with nucleic acid amplification to perform PCR. Disease in more than 60% of the patients with tuberculosis with smear-negative, culture-positive specimens can be diagnosed at the time of admission, and potentially all patients with smear-positive specimens can immediately be confirmed as being infected with M. tuberculosis, leading to improved clinical management.
Isaksson, Mats; Hagström, Åsa; Armua-Fernandez, Maria Teresa; Wahlström, Helene; Ågren, Erik Olof; Miller, Andrea; Holmberg, Anders; Lukacs, Morten; Casulli, Adriano; Deplazes, Peter; Juremalm, Mikael
2014-12-19
Following the first finding of Echinococcus multilocularis in Sweden in 2011, 2985 red foxes (Vulpes vulpes) were analysed by the segmental sedimentation and counting technique. This is a labour intensive method and requires handling of the whole carcass of the fox, resulting in a costly analysis. In an effort to reduce the cost of labour and sample handling, an alternative method has been developed. The method is sensitive and partially automated for detection of E. multilocularis in faecal samples. The method has been used in the Swedish E. multilocularis monitoring program for 2012-2013 on more than 2000 faecal samples. We describe a new semi-automated magnetic capture probe DNA extraction method and real time hydrolysis probe polymerase chain reaction assay (MC-PCR) for the detection of E. multilocularis DNA in faecal samples from red fox. The diagnostic sensitivity was determined by validating the new method against the sedimentation and counting technique in fox samples collected in Switzerland where E. multilocularis is highly endemic. Of 177 foxes analysed by the sedimentation and counting technique, E. multilocularis was detected in 93 animals. Eighty-two (88%, 95% C.I 79.8-93.9) of these were positive in the MC-PCR. In foxes with more than 100 worms, the MC-PCR was positive in 44 out of 46 (95.7%) cases. The two MC-PCR negative samples originated from foxes with only immature E. multilocularis worms. In foxes with 100 worms or less, (n = 47), 38 (80.9%) were positive in the MC-PCR. The diagnostic specificity of the MC-PCR was evaluated using fox scats collected within the Swedish screening. Of 2158 samples analysed, two were positive. This implies that the specificity is at least 99.9% (C.I. = 99.7-100). The MC-PCR proved to have a high sensitivity and a very high specificity. The test is partially automated but also possible to perform manually if desired. The test is well suited for nationwide E. multilocularis surveillance programs where sampling of fox scats is done to reduce the costs for sampling and where a test with a high sensitivity and a very high specificity is needed.
Radiation microscope for SEE testing using GeV ions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doyle, Barney Lee; Knapp, James Arthur; Rossi, Paolo
2009-09-01
Radiation Effects Microscopy is an extremely useful technique in failure analysis of electronic parts used in radiation environment. It also provides much needed support for development of radiation hard components used in spacecraft and nuclear weapons. As the IC manufacturing technology progresses, more and more overlayers are used; therefore, the sensitive region of the part is getting farther and farther from the surface. The thickness of these overlayers is so large today that the traditional microbeams, which are used for REM are unable to reach the sensitive regions. As a result, higher ion beam energies have to be used (>more » GeV), which are available only at cyclotrons. Since it is extremely complicated to focus these GeV ion beams, a new method has to be developed to perform REM at cyclotrons. We developed a new technique, Ion Photon Emission Microscopy, where instead of focusing the ion beam we use secondary photons emitted from a fluorescence layer on top of the devices being tested to determine the position of the ion hit. By recording this position information in coincidence with an SEE signal we will be able to indentify radiation sensitive regions of modern electronic parts, which will increase the efficiency of radiation hard circuits.« less
Smith, Matthew R.; Artz, Nathan S.; Koch, Kevin M.; Samsonov, Alexey; Reeder, Scott B.
2014-01-01
Purpose To demonstrate feasibility of exploiting the spatial distribution of off-resonance surrounding metallic implants for accelerating multispectral imaging techniques. Theory Multispectral imaging (MSI) techniques perform time-consuming independent 3D acquisitions with varying RF frequency offsets to address the extreme off-resonance from metallic implants. Each off-resonance bin provides a unique spatial sensitivity that is analogous to the sensitivity of a receiver coil, and therefore provides a unique opportunity for acceleration. Methods Fully sampled MSI was performed to demonstrate retrospective acceleration. A uniform sampling pattern across off-resonance bins was compared to several adaptive sampling strategies using a total hip replacement phantom. Monte Carlo simulations were performed to compare noise propagation of two of these strategies. With a total knee replacement phantom, positive and negative off-resonance bins were strategically sampled with respect to the B0 field to minimize aliasing. Reconstructions were performed with a parallel imaging framework to demonstrate retrospective acceleration. Results An adaptive sampling scheme dramatically improved reconstruction quality, which was supported by the noise propagation analysis. Independent acceleration of negative and positive off-resonance bins demonstrated reduced overlapping of aliased signal to improve the reconstruction. Conclusion This work presents the feasibility of acceleration in the presence of metal by exploiting the spatial sensitivities of off-resonance bins. PMID:24431210
Structural basis of orientation sensitivity of cat retinal ganglion cells.
Leventhal, A G; Schall, J D
1983-11-10
We investigated the structural basis of the physiological orientation sensitivity of retinal ganglion cells (Levick and Thibos, '82). The dendritic fields of 840 retinal ganglion cells labeled by injections of horseradish peroxidase into the dorsal lateral geniculate nucleus (LGNd) or optic tracts of normal cats. Siamese cats, and cat deprived of patterned visual experience from birth by monocular lid-suture (MD) were studied. Mathematical techniques designed to analyze direction were used to find the dendritic field orientation of each cell. Statistical techniques designed for angular data were used to determine the relationship between dendritic field orientation and angular position on the retina (polar angle). Our results indicate that 88% of retinal ganglion cells have oriented dendritic fields and that dendritic field orientation is related systematically to retinal position. In all regions of retina more that 0.5 mm from the area centralis the dendritic fields of retinal ganglion cells are oriented radially, i.e., like the spokes of a wheel having the area centralis at its hub. This relationship was present in all animals and cell types studied and was strongest for cells located close to the horizontal meridian (visual streak) of the retina. Retinal ganglion cells appear to be sensitive to stimulus orientation because they have oriented dendritic fields.
Gupta, Vikas; Chakravarti, Soumendu; Chander, Vishal; Majumder, Saurabh; Bhat, Shabir Ahmad; Gupta, Vivek Kumar; Nandi, Sukdeb
2017-07-01
Canine parvovirus-2 (CPV-2), which is ubiquitously distributed worldwide, causes severe and often fatal gastroenteritis in dogs. Accurate, differential and rapid diagnosis of canine parvoviral enteritis remains a challenge for clinicians. A recently developed isothermal amplification technique, polymerase spiral reaction (PSR), was optimized for the first time for a viral pathogen with reference recombinant plasmid standards from different CPV-2 antigenic variants (CPV-2, CPV-2a, CPV-2b and CPV-2c) and subsequently validated using clinical samples. Addition of chromogenic substrate SYBR Green I after the completion of the reaction resulted in bright green fluorescence in positive samples, while negative samples and a no-template control remained orange. These results were further substantiated through visualization of a laddering pattern of the PSR-amplified product in an agarose gel in positive cases and the absence of this pattern in no-template control and negative samples. The PSR assay was found to be highly specific, as it did not react with other putative canine pathogens (canine adenovirus 1 and canine distemper virus). The sensitivity of the newly developed PSR technique was compared with that of conventional PCR, real-time PCR and LAMP, using a serial tenfold dilution of canine parvovirus DNA. The detection limit of PSR was found to be at the femtogram level, which is comparable with that of real-time PCR and LAMP, which are ten times more sensitive than conventional PCR. The assay was validated using 90 clinical samples, of which 54 were found positive, while only 45 samples were positive in conventional PCR. This novel assay, which is fully compliant with the 'ASSURED' concept for disease diagnosis, provides a simple, rapid, specific, sensitive and cost-effective method for diagnosis of canine parvoviral enteritis in veterinary clinics.
Silva, Renata K N R; Pacheco, Flávia T F; Martins, Adson S; Menezes, Joelma F; Costa-Ribeiro, Hugo; Ribeiro, Tereza C M; Mattos, Ângela P; Oliveira, Ricardo R; Soares, Neci M; Teixeira, Márcia C A
2016-12-01
Techniques for Giardia diagnosis based on microscopy are usually applied as routine laboratory testing; however, they typically exhibit low sensitivity. This study aimed to evaluate Giardia duodenalis and other intestinal parasitic infections in different pediatric groups, with an emphasis on the comparison of Giardia diagnostic techniques. Feces from 824 children from different groups (diarrheic, malnourished, with cancer and from day care) were examined by microscopy and ELISA for Giardia, Cryptosporidium sp. and Entamoeba histolytica coproantigen detection. Giardia-positive samples from day-care children, identified by either microscopy or ELISA, were further tested by PCR targeting of the β-giardin and Gdh genes. Statistically significant differences (P<0.05) were observed when comparing the frequency of each protozoan among the groups. Giardia duodenalis was more frequent in day-care children and Cryptosporidium sp. in diarrheic and malnourished groups; infections by Entamoeba histolytica were found only in children with diarrhea. Considering positivity for Giardia by at least one method, ELISA was found to be more sensitive than microscopy (97% versus 55%). To examine discrepancies among the diagnostic methods, 71 Giardia-positive stool samples from day-care children were tested by PCR; of these, DNA was amplified from 51 samples (77.4%). Concordance of positivity between microscopy and ELISA was found for 48 samples, with 43 confirmed by PCR. Parasite DNA was amplified from eleven of the 20 Giardia samples (55%) identified only by ELISA. This study shows the higher sensitivity of ELISA over microscopy for Giardia diagnosis when a single sample is analyzed and emphasizes the need for methods based on coproantigen detection to identify this parasite in diarrheic fecal samples. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ocampo Giraldo, L.; Bolotnikov, A. E.; Camarda, G. S.; De Geronimo, G.; Fried, J.; Gul, R.; Hodges, D.; Hossain, A.; Ünlü, K.; Vernon, E.; Yang, G.; James, R. B.
2018-03-01
We evaluated the sub-pixel position resolution achievable in large-volume CdZnTe pixelated detectors with conventional pixel patterns and for several different pixel sizes: 2.8 mm, 1.72 mm, 1.4 mm and 0.8 mm. Achieving position resolution below the physical dimensions of pixels (sub-pixel resolution) is a practical path for making high-granularity position-sensitive detectors, <100 μm, using a limited number of pixels dictated by the mechanical constraints and multi-channel readout electronics. High position sensitivity is important for improving the imaging capability of CZT gamma cameras. It also allows for making more accurate corrections of response non-uniformities caused by crystal defects, thus enabling use of standard-grade (unselected) and less expensive CZT crystals for producing large-volume position-sensitive CZT detectors feasible for many practical applications. We analyzed the digitized charge signals from a representative 9 pixels and the cathode, generated using a pulsed-laser light beam focused down to 10 μm (650 nm) to scan over a selected 3 × 3 pixel area. We applied our digital pulse processing technique to the time-correlated signals captured from adjacent pixels to achieve and evaluate the capability for sub-pixel position resolution. As an example, we also demonstrated an application of 3D corrections to improve the energy resolution and positional information of the events for the tested detectors.
Giraldo, L. Ocampo; Bolotnikov, A. E.; Camarda, G. S.; ...
2017-12-18
Here, we evaluated the sub-pixel position resolution achievable in large-volume CdZnTe pixelated detectors with conventional pixel patterns and for several different pixel sizes: 2.8 mm, 1.72 mm, 1.4 mm and 0.8 mm. Achieving position resolution below the physical dimensions of pixels (sub-pixel resolution) is a practical path for making high-granularity position-sensitive detectors, <100 μμm, using a limited number of pixels dictated by the mechanical constraints and multi-channel readout electronics. High position sensitivity is important for improving the imaging capability of CZT gamma cameras. It also allows for making more accurate corrections of response non-uniformities caused by crystal defects, thus enablingmore » use of standard-grade (unselected) and less expensive CZT crystals for producing large-volume position-sensitive CZT detectors feasible for many practical applications. We analyzed the digitized charge signals from a representative 9 pixels and the cathode, generated using a pulsed-laser light beam focused down to 10 m (650 nm) to scan over a selected 3×3 pixel area. We applied our digital pulse processing technique to the time-correlated signals captured from adjacent pixels to achieve and evaluate the capability for sub-pixel position resolution. As an example, we also demonstrated an application of 3D corrections to improve the energy resolution and positional information of the events for the tested detectors.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giraldo, L. Ocampo; Bolotnikov, A. E.; Camarda, G. S.
Here, we evaluated the sub-pixel position resolution achievable in large-volume CdZnTe pixelated detectors with conventional pixel patterns and for several different pixel sizes: 2.8 mm, 1.72 mm, 1.4 mm and 0.8 mm. Achieving position resolution below the physical dimensions of pixels (sub-pixel resolution) is a practical path for making high-granularity position-sensitive detectors, <100 μμm, using a limited number of pixels dictated by the mechanical constraints and multi-channel readout electronics. High position sensitivity is important for improving the imaging capability of CZT gamma cameras. It also allows for making more accurate corrections of response non-uniformities caused by crystal defects, thus enablingmore » use of standard-grade (unselected) and less expensive CZT crystals for producing large-volume position-sensitive CZT detectors feasible for many practical applications. We analyzed the digitized charge signals from a representative 9 pixels and the cathode, generated using a pulsed-laser light beam focused down to 10 m (650 nm) to scan over a selected 3×3 pixel area. We applied our digital pulse processing technique to the time-correlated signals captured from adjacent pixels to achieve and evaluate the capability for sub-pixel position resolution. As an example, we also demonstrated an application of 3D corrections to improve the energy resolution and positional information of the events for the tested detectors.« less
Muñoz, L; López, O; Martino, R; Brunet, S; Bellido, M; Rubiol, E; Sierra, J; Nomdedéu, J F
2000-07-01
The Philadelphia chromosome in acute lymphoblastic leukemia (Ph+ ALL) is associated with a poor prognosis given the high frequency of chemoresistance and leukemia relapse. Minimal residual disease (MRD) detection before cytogenetic and hematologic relapse could be useful in early therapy. The most suitable methods for detecting MRD in Ph+ ALL are flow cytometry (FC) and reverse transcriptase polymerase chain reaction (RT-PCR). However, since both techniques carry the risk of false-negative results the combined use of these two techniques could overcome this problem. We report our experience using this approach in 47 bone marrow samples obtained from 10 Ph+ ALL patients. Twenty-seven marrow aspirates were taken from patients in clinical remission (CR). The samples were considered positive for MRD by FC when two conditions were met: 1) detection of an abnormal B-cell differentiation pattern and 2) presence of more than 1x10(-3) cells coexpressing CD22/CD34/CD45 or CD66/CD34/CD10. After FC analysis, RNA was purified using standard methods. FC was positive in 23/27 samples in CR (sensitivity 85%). RT-PCR was successfully performed in 23 samples in CR. RT-PCR was positive in 18/23 samples (sensitivity 78%). There were 5 samples with discordant results. FC was positive in 3 samples with a negative RT-PCR and FC was negative in 2 samples with a positive RT. All the 10 patients relapsed and only 1 is currently alive after an allogeneic stem cell transplantation (alloSCT). The median (range) time from MRD detection to relapse in patients treated with chemotherapy was 42 (39-71) days. These data suggest that RT-PCR may be negative despite the presence of neoplastic cells identified by their immunophenotypic traits. We conclude that immunologic and molecular techniques can be used in tandem for monitoring MRD in Ph+ ALL.
Shah, Ami P; Cobb, Benjamin T; Lower, Darla R; Shaikh, Nader; Rasmussen, Jayne; Hoberman, Alejandro; Wald, Ellen R; Rosendorff, Adam; Hickey, Robert W
2014-03-01
Urinary tract infections (UTI) are the most common serious bacterial infection in febrile infants. Urinalysis (UA) is a screening test for preliminary diagnosis of UTI. UA can be performed manually or using automated techniques. We sought to compare manual versus automated UA for urine specimens obtained via catheterization in the pediatric emergency department. In this prospective study, we processed catheterized urine samples from infants with suspected UTI by both the manual method (enhanced UA) and the automated method. We defined a positive enhanced UA as ≥ 10 white blood cells per cubic millimeter and presence of any bacteria per 10 oil immersion fields on a Gram-stained smear. We defined a positive automated UA as ≥ 2 white blood cells per high-powered field and presence of any bacteria using the IRIS iQ200 ELITE. We defined a positive urine culture as growth of ≥ 50,000 colony-forming units per milliliter of a single uropathogen. We analyzed data using SPSS software. A total of 703 specimens were analyzed. Prevalence of UTI was 7%. For pyuria, the sensitivity and positive predictive value (PPV) of the enhanced UA in predicting positive urine culture were 83.6% and 52.5%, respectively; corresponding values for the automated UA were 79.5% and 37.5%, respectively. For bacteriuria, the sensitivity and PPV of a Gram-stained smear (enhanced UA) were 83.6% and 59.4%, respectively; corresponding values for the automated UA were 73.4%, and 26.2%, respectively. Using criteria of both pyuria and bacteriuria for the enhanced UA resulted in a sensitivity of 77.5% and a PPV of 84.4%; corresponding values for the automated UA were 63.2% and 51.6%, respectively. Combining automated pyuria (≥ 2 white blood cells/high-powered microscopic field) with a Gram-stained smear resulted in a sensitivity of 75.5% and a PPV of 84%. Automated UA is comparable with manual UA for detection of pyuria in young children with suspected UTI. Bacteriuria detected by automated UA is less sensitive and specific for UTI when compared with a Gram-stained smear. We recommend using either manual or automated measurement of pyuria in combination with Gram-stained smear as the preferred technique for UA of catheterized specimens obtained from children in an acute care setting.
Study for online range monitoring with the interaction vertex imaging method.
Finck, Ch; Karakaya, Y; Reithinger, V; Rescigno, R; Baudot, J; Constanzo, J; Juliani, D; Krimmer, J; Rinaldi, I; Rousseau, M; Testa, E; Vanstalle, M; Ray, C
2017-11-21
Ion beam therapy enables a highly accurate dose conformation delivery to the tumor due to the finite range of charged ions in matter (i.e. Bragg peak (BP)). Consequently, the dose profile is very sensitive to patients anatomical changes as well as minor mispositioning, and so it requires improved dose control techniques. Proton interaction vertex imaging (IVI) could offer an online range control in carbon ion therapy. In this paper, a statistical method was used to study the sensitivity of the IVI technique on experimental data obtained from the Heidelberg Ion-Beam Therapy Center. The vertices of secondary protons were reconstructed with pixelized silicon detectors. The statistical study used the [Formula: see text] test of the reconstructed vertex distributions for a given displacement of the BP position as a function of the impinging carbon ions. Different phantom configurations were used with or without bone equivalent tissue and air inserts. The inflection points in the fall-off region of the longitudinal vertex distribution were computed using different methods, while the relation with the BP position was established. In the present setup, the resolution of the BP position was about 4-5 mm in the homogeneous phantom under clinical conditions (10 6 incident carbon ions). Our results show that the IVI method could therefore monitor the BP position with a promising resolution in clinical conditions.
Study for online range monitoring with the interaction vertex imaging method
NASA Astrophysics Data System (ADS)
Finck, Ch; Karakaya, Y.; Reithinger, V.; Rescigno, R.; Baudot, J.; Constanzo, J.; Juliani, D.; Krimmer, J.; Rinaldi, I.; Rousseau, M.; Testa, E.; Vanstalle, M.; Ray, C.
2017-12-01
Ion beam therapy enables a highly accurate dose conformation delivery to the tumor due to the finite range of charged ions in matter (i.e. Bragg peak (BP)). Consequently, the dose profile is very sensitive to patients anatomical changes as well as minor mispositioning, and so it requires improved dose control techniques. Proton interaction vertex imaging (IVI) could offer an online range control in carbon ion therapy. In this paper, a statistical method was used to study the sensitivity of the IVI technique on experimental data obtained from the Heidelberg Ion-Beam Therapy Center. The vertices of secondary protons were reconstructed with pixelized silicon detectors. The statistical study used the χ2 test of the reconstructed vertex distributions for a given displacement of the BP position as a function of the impinging carbon ions. Different phantom configurations were used with or without bone equivalent tissue and air inserts. The inflection points in the fall-off region of the longitudinal vertex distribution were computed using different methods, while the relation with the BP position was established. In the present setup, the resolution of the BP position was about 4-5 mm in the homogeneous phantom under clinical conditions (106 incident carbon ions). Our results show that the IVI method could therefore monitor the BP position with a promising resolution in clinical conditions.
[Identification of Vibrio cholerae O1 by flow cytometry].
Alvarado-Alemán, F J; González-Bonilla, C; Wong-Arambula, C; Gutiérrez-Cogco, L; Sepúlveda-Amor, J; Kumate-Rodríguez, J
1994-01-01
A total of 72 peptonated water samples suspected of carrying Vibrio cholerae were assessed by laser flow cytometry (LFC) and compared with positive culture. We used a direct fluorescence technique using polyclonal (PolAb) and monoclonal antibodies (MoAb) conjugated to fluorescein. The PolAb were able to detect 33 positive samples. A clear difference among the 20 positive samples was found with only three V. cholerae O1 false negatives when MoAb were used whereas all 13 V. cholerae Non O1 samples were detected. The correlation index comparing control autofluorescence with peptonated water samples show a R = 0.69, versus 0.96 with pure V. cholerae O1 strains. Our data suggest that the LFC technique is able to recognize V. cholerae O1 from a mixture of microorganisms with high sensitivity and specificity in a few hours.
Trinh, Tony W; Glazer, Daniel I; Sadow, Cheryl A; Sahni, V Anik; Geller, Nina L; Silverman, Stuart G
2018-03-01
To determine test characteristics of CT urography for detecting bladder cancer in patients with hematuria and those undergoing surveillance, and to analyze reasons for false-positive and false-negative results. A HIPAA-compliant, IRB-approved retrospective review of reports from 1623 CT urograms between 10/2010 and 12/31/2013 was performed. 710 examinations for hematuria or bladder cancer history were compared to cystoscopy performed within 6 months. Reference standard was surgical pathology or 1-year minimum clinical follow-up. False-positive and false-negative examinations were reviewed to determine reasons for errors. Ninety-five bladder cancers were detected. CT urography accuracy: was 91.5% (650/710), sensitivity 86.3% (82/95), specificity 92.4% (568/615), positive predictive value 63.6% (82/129), and negative predictive value was 97.8% (568/581). Of 43 false positives, the majority of interpretation errors were due to benign prostatic hyperplasia (n = 12), trabeculated bladder (n = 9), and treatment changes (n = 8). Other causes include blood clots, mistaken normal anatomy, infectious/inflammatory changes, or had no cystoscopic correlate. Of 13 false negatives, 11 were due to technique, one to a large urinary residual, one to artifact. There were no errors in perception. CT urography is an accurate test for diagnosing bladder cancer; however, in protocols relying predominantly on excretory phase images, overall sensitivity remains insufficient to obviate cystoscopy. Awareness of bladder cancer mimics may reduce false-positive results. Improvements in CTU technique may reduce false-negative results.
Wireless passive radiation sensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pfeifer, Kent B; Rumpf, Arthur N; Yelton, William G
2013-12-03
A novel measurement technique is employed using surface acoustic wave (SAW) devices, passive RF, and radiation-sensitive films to provide a wireless passive radiation sensor that requires no batteries, outside wiring, or regular maintenance. The sensor is small (<1 cm.sup.2), physically robust, and will operate unattended for decades. In addition, the sensor can be insensitive to measurement position and read distance due to a novel self-referencing technique eliminating the need to measure absolute responses that are dependent on RF transmitter location and power.
NASA Astrophysics Data System (ADS)
Holá, Miroslava; Lazar, Josef; Čížek, Martin; Hucl, Václav; Řeřucha, Šimon; Číp, Ondřej
2016-11-01
We report on a design of an interferometric position measuring system for control of a sample stage in an e-beam writer with reproducibility of the position on nanometer level and resolution below nanometer. We introduced differential configuration of the interferometer where the position is measured with respect to a central reference point to eliminate deformations caused by thermal and pressure effects on the vacuum chamber. The reference is here the electron gun of the writer. The interferometer is designed to operate at infrared, telecommunication wavelength due to the risk of interference of stray light with sensitive photodetectors in the chamber. The laser source is here a narrow-linewidth DFB laser diode with electronics of our own design offering precision and stability of temperature and current, low-noise, protection from rf interference, and high-frequency modulation. Detection of the interferometric signal relies on a novel derivative technique utilizing hf frequency modulation and phase-sensitive detection.
Comparison of PCR, culturing and Pap smear microscopy for accurate diagnosis of genital Actinomyces.
Kaya, Dilek; Demirezen, Şayeste; Hasçelik, Gülşen; Gülmez Kivanç, Dolunay; Beksaç, Mehmet Sinan
2013-05-01
Members of the genus Actinomyces, Gram-positive, non-spore-forming anaerobic bacteria, are normal inhabitants of the mucosal surfaces of the oral, gastrointestinal and genital tracts. Identification of these bacteria using conventional methods is generally difficult because of their complex transport and growth requirements and their fastidious and slow-growing nature. However, in recent years, the advancement of molecular techniques has provided much improved identification and differentiation of closely related Actinomyces species. The aim of the present study was to evaluate the efficacy of the PCR technique in the diagnosis of genital Actinomyces in comparison with culturing and Papanicolaou (Pap) smear microscopy. Multiple sampling was conducted from 200 women using smear microscopy, culturing and PCR. Cyto-brushes were smeared on glass slides and stained using the routine Pap technique. Culturing was performed from a sterile swab, and Actinomyces were determined using the BBL Crystal ANR ID kit. PCR was performed from a second swab, and the Actinomyces type was determined using type-specific primers designed in our laboratory. Only one vaginal fluid sample (0.5%) revealed Actinomyces-like organisms on Pap smear examination. Actinomyces were detected in nine samples (4.5%) using the BBL Crystal ANR ID kit. Using PCR, eight samples (4%) were found positive for Actinomyces. No specimens that gave positive results by Pap smear microscopy and culturing could be confirmed by PCR. Pap smear microscopy and culturing were both found to have zero sensitivity for Actinomyces. PCR appears to be a sensitive and reliable diagnostic method for the detection of Actinomyces, which are difficult to cultivate from genital samples. PCR can be used for diagnostic confirmation in cases diagnosed by conventional methods, to prevent false-positive results.
Serologic screening for Trypanosoma cruzi among blood donors in central Brazil.
de Andrade, A L; Martelli, C M; Luquetti, A O; de Oliveira, O S; Almeida e Silva, S; Zicker, F
1992-01-01
The study reported here compares results obtained by blood banks screening sera for chagasic (Trypanosoma cruzi) infection with results obtained by the Chagas' Disease Reference Laboratory of the Federal University of Goiás in Goiânia, Brazil. It also evaluates results obtained using the ELISA technique to screen the study sera. The survey used data from six of eight blood banks serving the city of Goiânia, an urban region of Central Brazil where Chagas' disease is highly endemic. The survey population consisted of 1,513 voluntary first-time blood donors whose donations occurred between October 1988 and April 1989. This group included 50% of all the first-time blood donors in that period. The six participating blood banks, which accounted for about 90% of all blood donations in Goiânia during the study period, routinely used indirect hemagglutination (IHA) and complement fixation (CF) tests to screen sera for antibodies to T. cruzi. Comparison of the results provided by the blood banks with the reference laboratory's results indicated a relative sensitivity of 77%, which ranged from 50% to 100% depending on the blood bank studied. The comparison, which found 12 false negative results, indicated that transfusions of infected blood might have occurred despite the serologic screening performed by the blood banks. Relative to the standard of positivity established for the study, the enzyme-linked immunosorbent assay (ELISA) technique was found to have a sensitivity of 96.3%. Considering as positive only those sera yielding positive IHA and indirect immunofluorescence (IIF) test results, the ELISA technique yielded 2 false negative and 41 false positive responses.(ABSTRACT TRUNCATED AT 250 WORDS)
Ruiz-Manzano, J; Manterola, J M; Gamboa, F; Calatrava, A; Monsó, E; Martínez, C; Ausina, V
2000-09-01
To evaluate the utility of two gene amplification systems in historical paraffin-embedded pleural biopsy (PEB) tissues from patients with pleural tuberculosis, and to compare the results to those obtained with conventional histologic and microbiological methods. A retrospective study. Seventy-four formalin-fixed PEB tissues collected and stored over 12 years (1984 through 1995) were retrieved. Gene amplifications were performed in 57 tissues from patients with diagnoses of pleural tuberculosis and in 17 from patients with carcinoma as controls, using the first version of the Amplified Mycobacterium tuberculosis Direct Test (AMTDT; Gen-Probe; San Diego, CA) and the LCx Mycobacterium tuberculosis Assay (LCxMTB; Abbott Laboratories; Abbott Park, IL). The sensitivities of the AMTDT and LCxMTB were 52.6% and 63.2%, respectively (p = not statistically significant). The specificity of both tests was 100%. Twenty tissue samples (35.1%) were positive by both systems, and 10 tissues (17.5%) were positive only by the AMTDT, while 16 tissues (28.1%) were positive only by the LCxMTB. Both tests gave negative results for 11 specimens (19.3%). When both tests were used, a positive diagnosis was achieved in 80.7% of the samples. Diagnosis of 73.7% of patient conditions had previously been made by smear examination of pleural biopsy and sputum, pleural liquid, or biopsy culture. The overall diagnostic yield with both culture and amplification techniques was 96.5% (55 of 57 patients) for pleural tuberculosis, with amplification techniques adding 22.8% of the diagnoses. Amplification techniques are useful in archival PEB tissues, providing additional diagnoses beyond culturing, although the sensitivity should be improved, possibly by standardizing protocols.
Micó, Miquel; Navarro, Ferran; de Miniac, Daniela; González, Yésica; Brell, Albert; López, Cristina; Sánchez-Reus, Ferran; Mirelis, Beatriz; Coll, Pere
2015-12-01
Molecular-based techniques reduce the delay in diagnosing infectious diseases and therefore contribute to better patient outcomes. We assessed the FilmArray blood culture identification (BCID) panel (Biofire Diagnostics/bioMérieux) directly on clinical specimens other than blood: cerebrospinal, joint, pleural and ascitic fluids, bronchoscopy samples and abscesses. We compared the results from 88 samples obtained by culture-based techniques. The percentage of agreement between the two methods was 75 % with a Cohen κ value of 0.51. Global sensitivity and specificity using the FilmArray BCID panel were 71 and 97 %, respectively. Sensitivity was poorer in samples with a low bacterial load, such as ascitic and pleural fluids (25 %), whereas the sensitivity for abscess samples was high (89 %). These findings suggest that the FilmArray BCID panel could be useful to perform microbiological diagnosis directly from samples other than positive blood cultures, as it offers acceptable sensitivity and moderate agreement with conventional microbiological methods. Nevertheless, cost-benefit studies should be performed before introducing this method into algorithms for microbiological diagnostics.
Levecke, Bruno; De Wilde, Nathalie; Vandenhoute, Els; Vercruysse, Jozef
2009-01-01
Background Soil-transmitted helminths, such as Trichuris trichiura, are of major concern in public health. Current efforts to control these helminth infections involve periodic mass treatment in endemic areas. Since these large-scale interventions are likely to intensify, monitoring the drug efficacy will become indispensible. However, studies comparing detection techniques based on sensitivity, fecal egg counts (FEC), feasibility for mass diagnosis and drug efficacy estimates are scarce. Methodology/Principal Findings In the present study, the ether-based concentration, the Parasep Solvent Free (SF), the McMaster and the FLOTAC techniques were compared based on both validity and feasibility for the detection of Trichuris eggs in 100 fecal samples of nonhuman primates. In addition, the drug efficacy estimates of quantitative techniques was examined using a statistical simulation. Trichuris eggs were found in 47% of the samples. FLOTAC was the most sensitive technique (100%), followed by the Parasep SF (83.0% [95% confidence interval (CI): 82.4–83.6%]) and the ether-based concentration technique (76.6% [95% CI: 75.8–77.3%]). McMaster was the least sensitive (61.7% [95% CI: 60.7–62.6%]) and failed to detect low FEC. The quantitative comparison revealed a positive correlation between the four techniques (Rs = 0.85–0.93; p<0.0001). However, the ether-based concentration technique and the Parasep SF detected significantly fewer eggs than both the McMaster and the FLOTAC (p<0.0083). Overall, the McMaster was the most feasible technique (3.9 min/sample for preparing, reading and cleaning of the apparatus), followed by the ether-based concentration technique (7.7 min/sample) and the FLOTAC (9.8 min/sample). Parasep SF was the least feasible (17.7 min/sample). The simulation revealed that the sensitivity is less important for monitoring drug efficacy and that both FLOTAC and McMaster were reliable estimators. Conclusions/Significance The results of this study demonstrated that McMaster is a promising technique when making use of FEC to monitor drug efficacy in Trichuris. PMID:19172171
McCusker, J J; McCoy, E L; Young, C L; Alamares, R; Hirsch, L S
1984-01-01
The Directigen Group A Strep Test (DGAST), a new rapid method of detecting group A beta-hemolytic streptococci directly from throat swabs, was compared with a traditional culture technique for the detection of group A beta-hemolytic streptococci. Five hundred oropharyngeal swabs from pediatric and adult patients were cultured and then processed by using the DGAST. Of the 144 specimens positive by culture, 131 were DGAST positive (sensitivity, 90.9%). Of the 356 specimens negative by culture, 353 were DGAST negative (specificity, 99.2%). Twelve of the 13 false-negative DGAST results were from pediatric patients. One hundred isolates of non-group A beta-hemolytic streptococci were recovered, primarily groups C, F, and G. The DGAST is easy to perform, rapid, sensitive, and very specific for detection of group A beta-hemolytic streptococci directly from swabs. Supplementing the DGAST with a culture on a 5% sheep blood agar plate would enhance detection of group A beta-hemolytic streptococci, especially in pediatric patients. PMID:6386884
Study of aluminum content in a welding metal by thermoelectric measurements
NASA Astrophysics Data System (ADS)
Carreón, H.; Ramirez, S.; Coronado, C.; Salazar, M.
2018-03-01
This work investigates the effect caused by the aluminum content in a welding metal and its variation in mechanical properties through the use of a non-destructive thermoelectric technique. It is known that aluminum has positive effects as deoxidizer in low percentages and alloying element together with Niobium and Vanadium. Aluminum has a positive and negative effect, initially improves the mechanical properties of the metal, as it acts as a grain refiner, increasing the yield strength, but in larger quantities, important mechanical properties such as hardness and toughness are seriously affected. For this purpose, HSLA ASTM 572 Gr. 50 steel was used as the base metal, where the weld metal was deposited, after which the specimens were fabricated and the mechanical tests and non-destructive tests were carried out. The sensitivity of the thermoelectric potential technique to microstructural and chemical composition changes was confirmed. The evolution of absolute thermoelectric potential (TEP) values with respect to the percentage of aluminum added to the weld was observed, being also quite sensitive to defects such as micro-cracks.
Risk factors for latex allergy in patients with spina bifida and latex sensitization.
Bernardini, R; Novembre, E; Lombardi, E; Mezzetti, P; Cianferoni, A; Danti, D A; Mercurella, A; Vierucci, A
1999-05-01
Some subjects with spina bifida (SB) and latex sensitization (cutaneous and/or serum IgE) can have clinical reactions, while others may have no symptoms after the exposure to latex products. This study was carried out to determine the risk factors associated with latex allergy in patients affected with SB and latex sensitization. Fifty-nine consecutive subjects affected with SB, besides answering a questionnaire, underwent a skin-prick test (SPT) to latex and the determination of the specific serum IgE (RAST CAP) to latex. The total serum IgE concentration was determined and SPT to common aero- and food-allergens, skin tests (prick + prick) with fresh foods (kiwi, pear, orange, pineapple, tomato, banana) and RAST CAP to the same foods tested by the prick + prick technique, were also performed. Fifteen out of the 59 subjects (25%) were sensitized to latex according to the presence of IgE to latex detected by SPT (nine patients) and/or RAST CAP (13 patients). Five out of the 15 sensitized patients (33%) suffered from clinical reactions to latex (urticaria, conjunctivitis, angioedema, rhinitis, bronchial asthma) while they were using latex gloves and while inflating latex balloons. In the 15 sensitized patients, the presence of specific latex seric IgE > 3.5 kU/L (>/= class 3), a positive latex SPT, an elevated total serum IgE, and a positive prick + prick and/or a positive RAST CAP to foods, were significant (P < 0.05) risk factors associated with latex symptoms. The other factors tested (age, gender, months of intermittent bladder catheterization, surgical procedures, SPT reactivity and clinical reactions to aero-allergens and food-allergens, skin tests for fresh foods, positive RAST CAP to foods) were not significantly different in symptomatic and asymptomatic patients. Significant risk factors for symptoms to latex in patients with SB and latex sensitization were a presence of specific IgE to latex > 3.5 kU/L, a more frequent positive latex SPT, elevated total IgE, and one or more positive prick + prick and/or RAST CAP to fresh foods.
Discriminating DNA mismatches by electrochemical and gravimetric techniques.
Mazouz, Zouhour; Fourati, Najla; Zerrouki, Chouki; Ommezine, Asma; Rebhi, Lamia; Yaakoubi, Nourdin; Kalfat, Rafik; Othmane, Ali
2013-10-15
A silicon nitride functionalized electrode and a 104 MHz lithium tantalate (LiTaO₃) surface acoustic wave (SAW) sensor have been used to investigate target-probe recognition processes. Electrochemical and gravimetric measurements have been considered to monitor hybridization of single base mismatch (SBM) in synthetic oligonucleotides and single-nucleotide polymorphisms ApoE in real clinical genotypes. Obvious discrimination of SBM in nucleotides has been shown by both gravimetric and electrochemical techniques, without labeling nor amplification. Investigations on mismatches nature and position have also been considered. For guanine-adenine (GA), guanine-thymine (GT) and guanine-guanine (GG) mismatches, the sensors responses present a dependence upon positions. Considering the capacitance variations and hybridization rates, results showed that gravimetric transduction is more sensitive than electrochemical one. Moreover, the highest value of GT hybridization rate (in the middle position) was found in accordance with the nearest-neighbor model, where the considered configuration appears as the most thermodynamically stable. For the real samples, where the electrochemical transduction, by combining capacitance and flat-band potential measurements, were found more sensitive, the results show that the realized sensor permits an unambiguous discrimination of recognition between fully complementary, non-complementary and single base mismatched targets, and even between the combination of differently matched strands. Copyright © 2013 Elsevier B.V. All rights reserved.
Mechanistic Basis of Sensitivity/Resistance Towards Anti-Cancer Drugs Targeting Topoisomerase II
2004-04-01
spectrometry footprinting. With the cysteine footprinting technique, we have shown that menadione may induce conformational changes in hstopo Ila that...footprinting approach, we have located a potential cysteine residue on hstopo Ila that may be modified by menadione . These preliminary results provide...the first direct evidence that menadione may act as an anticancer drug by binding to a specific position(s) on hstopo Ila causing it to adopt a conformation contrary to the wild-type form.
Laboratory Workflow Analysis of Culture of Periprosthetic Tissues in Blood Culture Bottles.
Peel, Trisha N; Sedarski, John A; Dylla, Brenda L; Shannon, Samantha K; Amirahmadi, Fazlollaah; Hughes, John G; Cheng, Allen C; Patel, Robin
2017-09-01
Culture of periprosthetic tissue specimens in blood culture bottles is more sensitive than conventional techniques, but the impact on laboratory workflow has yet to be addressed. Herein, we examined the impact of culture of periprosthetic tissues in blood culture bottles on laboratory workflow and cost. The workflow was process mapped, decision tree models were constructed using probabilities of positive and negative cultures drawn from our published study (T. N. Peel, B. L. Dylla, J. G. Hughes, D. T. Lynch, K. E. Greenwood-Quaintance, A. C. Cheng, J. N. Mandrekar, and R. Patel, mBio 7:e01776-15, 2016, https://doi.org/10.1128/mBio.01776-15), and the processing times and resource costs from the laboratory staff time viewpoint were used to compare periprosthetic tissues culture processes using conventional techniques with culture in blood culture bottles. Sensitivity analysis was performed using various rates of positive cultures. Annualized labor savings were estimated based on salary costs from the U.S. Labor Bureau for Laboratory staff. The model demonstrated a 60.1% reduction in mean total staff time with the adoption of tissue inoculation into blood culture bottles compared to conventional techniques (mean ± standard deviation, 30.7 ± 27.6 versus 77.0 ± 35.3 h per month, respectively; P < 0.001). The estimated annualized labor cost savings of culture using blood culture bottles was $10,876.83 (±$337.16). Sensitivity analysis was performed using various rates of culture positivity (5 to 50%). Culture in blood culture bottles was cost-effective, based on the estimated labor cost savings of $2,132.71 for each percent increase in test accuracy. In conclusion, culture of periprosthetic tissue in blood culture bottles is not only more accurate than but is also cost-saving compared to conventional culture methods. Copyright © 2017 American Society for Microbiology.
Comparison of the biopsy and cytobrush techniques for diagnosis of subclinical endometritis in mares
2014-01-01
Background Endometritis is a major cause of infertility in the mare. Therefore, the diagnosis of this disease is very important in veterinary practice. The objective of this study was to compare bacteriological and cytological results obtained from the mare uterus using biopsy (EB) and cytobrush (CB) techniques and relating these findings to the presence of polymorphonuclear cells (PMNs) in endometrial tissue as the gold standard for detection of endometritis. In particular, we tested the hypothesis that endometrial cytology and microbiology data obtained from material collected using the EB and CB techniques are similar, so that the CB technique could preferentially be used to detect subclinical endometritis in clinical practice. Methods A total of 69 mares suspected of subclinical endometritis because of previous reproductive history and 15 maiden mares were enrolled in this study. Material collected from both EB and CB was smeared on sterile glass slides for cytological examinations and on culture media for microbiological examinations. Bacteriological cultures and cytological samples were classified as negative (no growth or mixed cultures of more than three microorganisms; <2% PMNs) or positive (pure growth of microorganisms; >2% PMNs) for endometritis. Results Positive growth was observed in 43% of CB samples and in 54% of EB samples (difference not significant). The growth of β-hemolytic streptococci was always connected with positive cytology. This relationship was not observed for growth of E. coli or for non-pathogenic flora. The sensitivity of bacterial growth and cytology from EB was 0.63 and 0.73 respectively. The sensitivities of bacterial growth and cytology from CB were 0.50 and 0.71 respectively. Conclusion Microbiological and cytological results obtained from CB are similar to those obtained from EB and based on these findings the CB technique may be recommended for collection of materials from the mare’s uterus in clinical practice. PMID:24708825
Osman, Mamoun M M; Nour, Bakri Y M; Sedig, Mohamed F; De Bes, Laura; Babikir, Adil M; Mohamedani, Ahmed A; Mens, Petra F
2010-12-01
Rapid diagnostic tests (RDTs) are promoted for the diagnosis of malaria in many countries. The question arises whether laboratories where the current method of diagnosis is microscopy should also switch to RDT. This problem was studied in Kassala, Sudan where the issue of switching to RDT is under discussion. Two hundred and three blood samples were collected from febrile patients suspected of having malaria. These were subsequently analysed with microscopy, RDT (SD Bioline P.f/P.v) and PCR for the detection and identification of Plasmodium parasites. Malaria parasites were detected in 36 blood samples when examined microscopically, 54 (26.6%) samples were found positive for malaria parasites by RDT, and 44 samples were positive by PCR. Further analysis showed that the RDT used in our study resulted in a relatively high number of false positive samples. When microscopy was compared with PCR, an agreement of 96.1% and k = 0.88 (sensitivity 85.7% and specificity 100%) was found. However, when RDT was compared with PCR, an agreement of only 81.2 and k = 0.48 (sensitivity 69% and specificity 84%) was found. PCR has proven to be one of the most specific and sensitive diagnostic methods, particularly for malaria cases with low parasitaemia. However, this technique has limitations in its routine use under resource-limited conditions, such as our study location. At present, based on these results, microscopy remains the best option for routine diagnosis of malaria in Kassala, eastern Sudan. © 2010 Blackwell Publishing Ltd.
Prevalence of and risk factors for latex sensitization in patients with spina bifida.
Bernardini, R; Novembre, E; Lombardi, E; Mezzetti, P; Cianferoni, A; Danti, A D; Mercurella, A; Vierucci, A
1998-11-01
We determined the prevalence of and risk factors for latex sensitization in patients with spina bifida. A total of 59 consecutive subjects 2 to 40 years old with spina bifida answered a questionnaire, and underwent a latex skin prick test and determination of serum IgE specific for latex by RAST CAP radioimmunoassay. We also noted the relationships of total serum IgE skin prick tests to common air and food allergens. In addition, skin prick plus prick tests were also done with fresh foods, including kiwi, pear, orange, almond, pineapple, apple, tomato and banana. Latex sensitization was present in 15 patients (25%) according to the presence of IgE specific to latex, as detected by a skin prick test in 9 and/or RAST CAP in 13. Five latex sensitized patients (33.3%) had clinical manifestations, such as urticaria, conjuctivitis, angioedema, rhinitis and bronchial asthma, while using a latex glove and inflating a latex balloon. Atopy was present in 21 patients (35.6%). In 14 patients (23%) 1 or more skin tests were positive for fresh foods using a prick plus prick technique. Tomato, kiwi, and pear were the most common skin test positive foods. Univariate analysis revealed that a history of 5 or more operations, atopy and positive prick plus prick tests results for pear and kiwi were significantly associated with latex sensitization. Multivariate analysis demonstrated that only atopy and a history of 5 or more operations were significantly and independently associated with latex sensitization. A fourth of the patients with spina bifida were sensitized to latex. Atopy and an elevated number of operations were significant and independent predictors of latex sensitization in these cases.
Wong, Melody Yee-Man; Man, Sin-Heng; Che, Chi-Ming; Lau, Kai-Chung; Ng, Kwan-Ming
2014-03-21
The simplicity and easy manipulation of a porous substrate-based ESI-MS technique have been widely applied to the direct analysis of different types of samples in positive ion mode. However, the study and application of this technique in negative ion mode are sparse. A key challenge could be due to the ease of electrical discharge on supporting tips upon the application of negative voltage. The aim of this study is to investigate the effect of supporting materials, including polyester, polyethylene and wood, on the detection sensitivity of a porous substrate-based negative ESI-MS technique. By using nitrobenzene derivatives and nitrophenol derivatives as the target analytes, it was found that the hydrophobic materials (i.e., polyethylene and polyester) with a higher tendency to accumulate negative charge could enhance the detection sensitivity towards nitrobenzene derivatives via electron-capture ionization; whereas, compounds with electron affinities lower than the cut-off value (1.13 eV) were not detected. Nitrophenol derivatives with pKa smaller than 9.0 could be detected in the form of deprotonated ions; whereas polar materials (i.e., wood), which might undergo competitive deprotonation with the analytes, could suppress the detection sensitivity. With the investigation of the material effects on the detection sensitivity, the porous substrate-based negative ESI-MS method was developed and applied to the direct detection of two commonly encountered explosives in complex samples.
Local indicators of geocoding accuracy (LIGA): theory and application
Jacquez, Geoffrey M; Rommel, Robert
2009-01-01
Background Although sources of positional error in geographic locations (e.g. geocoding error) used for describing and modeling spatial patterns are widely acknowledged, research on how such error impacts the statistical results has been limited. In this paper we explore techniques for quantifying the perturbability of spatial weights to different specifications of positional error. Results We find that a family of curves describes the relationship between perturbability and positional error, and use these curves to evaluate sensitivity of alternative spatial weight specifications to positional error both globally (when all locations are considered simultaneously) and locally (to identify those locations that would benefit most from increased geocoding accuracy). We evaluate the approach in simulation studies, and demonstrate it using a case-control study of bladder cancer in south-eastern Michigan. Conclusion Three results are significant. First, the shape of the probability distributions of positional error (e.g. circular, elliptical, cross) has little impact on the perturbability of spatial weights, which instead depends on the mean positional error. Second, our methodology allows researchers to evaluate the sensitivity of spatial statistics to positional accuracy for specific geographies. This has substantial practical implications since it makes possible routine sensitivity analysis of spatial statistics to positional error arising in geocoded street addresses, global positioning systems, LIDAR and other geographic data. Third, those locations with high perturbability (most sensitive to positional error) and high leverage (that contribute the most to the spatial weight being considered) will benefit the most from increased positional accuracy. These are rapidly identified using a new visualization tool we call the LIGA scatterplot. Herein lies a paradox for spatial analysis: For a given level of positional error increasing sample density to more accurately follow the underlying population distribution increases perturbability and introduces error into the spatial weights matrix. In some studies positional error may not impact the statistical results, and in others it might invalidate the results. We therefore must understand the relationships between positional accuracy and the perturbability of the spatial weights in order to have confidence in a study's results. PMID:19863795
Gago, Sara; Esteban, Cristina; Valero, Clara; Zaragoza, Oscar; Puig de la Bellacasa, Jorge; Buitrago, María José
2014-04-01
A molecular diagnostic technique based on real-time PCR was developed for the simultaneous detection of three of the most frequent causative agents of fungal opportunistic pneumonia in AIDS patients: Pneumocystis jirovecii, Histoplasma capsulatum, and Cryptococcus neoformans/Cryptococcus gattii. This technique was tested in cultured strains and in clinical samples from HIV-positive patients. The methodology used involved species-specific molecular beacon probes targeted to the internal transcribed spacer regions of the rDNA. An internal control was also included in each assay. The multiplex real-time PCR assay was tested in 24 clinical strains and 43 clinical samples from AIDS patients with proven fungal infection. The technique developed showed high reproducibility (r(2) of >0.98) and specificity (100%). For H. capsulatum and Cryptococcus spp., the detection limits of the method were 20 and 2 fg of genomic DNA/20 μl reaction mixture, respectively, while for P. jirovecii the detection limit was 2.92 log10 copies/20 μl reaction mixture. The sensitivity in vitro was 100% for clinical strains and 90.7% for clinical samples. The assay was positive for 92.5% of the patients. For one of the patients with proven histoplasmosis, P. jirovecii was also detected in a bronchoalveolar lavage sample. No PCR inhibition was detected. This multiplex real-time PCR technique is fast, sensitive, and specific and may have clinical applications.
Diagnosis of group A streptococcal infections directly from throat secretions.
Edwards, E A; Phillips, I A; Suiter, W C
1982-01-01
The diagnosis of group A streptococcal disease still relies on isolation of group A streptococcal strains on sheep blood agar followed by presumptive identification based on bacitracin sensitivity or the results of the more precise serogrouping methods such as the Lancefield precipitin test. A technique that would permit rapid identification of streptococcal infections directly from throat secretions would allow immediate appropriate antimicrobial therapy for the management of streptococcal infections to be started. We have been able to identify soluble group A antigen directly from throat secretions by using a latex agglutination test. In a clinical trial in which latex (Streptex group A) and conventional culturing techniques were used, 53 throat secretion cultures were tested: 26 were positive by both procedures, 5 were positive by culture only, 3 were positive by the latex agglutination test only, and 19 were negative by both tests. Images PMID:7042747
Salimnia, Hossein; Lephart, Paul R.; Schreckenberger, Paul; DesJarlais, Sharon M.; Johnson, J. Kristie; Robinson, Gwen; Carroll, Karen C.; Greer, Amy; Morgan, Margie; Chan, Raymond; Loeffelholz, Michael; Valencia-Shelton, Frances; Jenkins, Stephen; Schuetz, Audrey N.; Daly, Judy A.; Barney, Trenda; Hemmert, Andrew; Kanack, Kristen J.
2016-01-01
Sepsis is a major cause of morbidity, mortality, and increased medical expense. Rapid diagnosis improves outcomes and reduces costs. The FilmArray blood culture identification panel (BioFire Diagnostics LLC, Salt Lake City, UT), a highly multiplexed PCR assay, can identify 24 etiologic agents of sepsis (8 Gram-positive, 11 Gram-negative, and 5 yeast species) and three antimicrobial resistance genes (mecA, vanA/B, and blaKPC) from positive blood culture bottles. It provides results in about 1 h with 2 min for assay setup. We present the results of an eight-center trial comparing the sensitivity and specificity of the panel with those of the laboratories' standard phenotypic identification techniques, as well as with molecular methods used to distinguish Acinetobacter baumannii from other members of the A. calcoaceticus-A. baumannii complex and to detect antimicrobial resistance genes. Testing included 2,207 positive aerobic blood culture samples, 1,568 clinical and 639 seeded. Samples were tested fresh or were frozen for later testing within 8 h after the bottles were flagged as positive by an automated blood culture system. At least one organism was detected by the panel in 1,382 (88.1%) of the positive clinical specimens. The others contained primarily off-panel organisms. The panel reported multiple organisms in 81 (5.86%) positive clinical specimens. The unresolved blood culture identification sensitivity for all target detections exceeded 96%, except for Klebsiella oxytoca (92.2%), which achieved 98.3% sensitivity after resolution of an unavoidable phenotypic error. The sensitivity and specificity for vanA/B and blaKPC were 100%; those for mecA were 98.4 and 98.3%, respectively. PMID:26739158
Alves, Vinicius M.; Muratov, Eugene; Fourches, Denis; Strickland, Judy; Kleinstreuer, Nicole; Andrade, Carolina H.; Tropsha, Alexander
2015-01-01
Repetitive exposure to a chemical agent can induce an immune reaction in inherently susceptible individuals that leads to skin sensitization. Although many chemicals have been reported as skin sensitizers, there have been very few rigorously validated QSAR models with defined applicability domains (AD) that were developed using a large group of chemically diverse compounds. In this study, we have aimed to compile, curate, and integrate the largest publicly available dataset related to chemically-induced skin sensitization, use this data to generate rigorously validated and QSAR models for skin sensitization, and employ these models as a virtual screening tool for identifying putative sensitizers among environmental chemicals. We followed best practices for model building and validation implemented with our predictive QSAR workflow using random forest modeling technique in combination with SiRMS and Dragon descriptors. The Correct Classification Rate (CCR) for QSAR models discriminating sensitizers from non-sensitizers were 71–88% when evaluated on several external validation sets, within a broad AD, with positive (for sensitizers) and negative (for non-sensitizers) predicted rates of 85% and 79% respectively. When compared to the skin sensitization module included in the OECD QSAR toolbox as well as to the skin sensitization model in publicly available VEGA software, our models showed a significantly higher prediction accuracy for the same sets of external compounds as evaluated by Positive Predicted Rate, Negative Predicted Rate, and CCR. These models were applied to identify putative chemical hazards in the ScoreCard database of possible skin or sense organ toxicants as primary candidates for experimental validation. PMID:25560674
Reborn quadrant anode image sensor
NASA Astrophysics Data System (ADS)
Prokazov, Yury; Turbin, Evgeny; Vitali, Marco; Herzog, Andreas; Michaelis, Bernd; Zuschratter, Werner; Kemnitz, Klaus
2009-06-01
We describe a position sensitive photon counting microchannel plate based detector with an improved quadrant anode (QA) readout system. The technique relies on a combination of the four planar elements pattern and an additional fifth electrode. The charge cloud induced by single particle detection is split between the electrodes. The measured charge values uniquely define the position of the initial event. QA has been first published in 1976 by Lampton and Malina. This anode configuration was undeservedly forgotten and its potential has been hardly underestimated. The presented approach extends the operating spatial range to the whole sensitive area of the microchannel plate surface and demonstrates good linearity over the field of view. Therefore, the novel image sensor results in spatial resolution better then 50 μm and count rates up to one million events per second.
Role of blind closed pleural biopsy in the managment of pleural exudates.
Pereyra, Marco F; San-José, Esther; Ferreiro, Lucía; Golpe, Antonio; Antúnez, José; González-Barcala, Francisco-Javier; Abdulkader, Ihab; Álvarez-Dobaño, José M; Rodríguez-Núñez, Nuria; Valdés, Luis
2013-01-01
The performance of blind closed pleural biopsy (BCPB) in the study of pleural exudates is controversial. To assess the diagnostic yield of BCPB in clinical practice and its role in the study of pleural exudates. Data were retrospectively collected on all patients who underwent BCPB performed between January 1999 and December 2011. A total of 658 BCPBs were performed on 575 patients. Pleural tissue was obtained in 590 (89.7%) of the biopsies. A malignant pleural effusion was found in 35% of patients. The cytology and the BCPB were positive in 69.2% and 59.2% of the patients, respectively. Of the patients with negative cytology, 21 had a positive BCPB (diagnostic improvement, 15%), which would have avoided one pleuroscopy for every seven BCPBs that were performed. Of the 113 patients with a tuberculous effusion, granulomas were observed in 87 and the Lowenstein culture was positive in an additional 17 (sensitivity 92%). The overall sensitivity was 33.9%, with a specificity and positive predictive value of 100%, and a negative predictive value of 71%. Complications were recorded in 14.4% of patients (pneumothorax 9.4%; chest pain 5.6%; vasovagal reaction, 4.1%; biopsy of another organ 0.5%). BCPB still has a significant role in the study of a pleural exudate. If an image-guided technique is unavailable, it seems reasonable to perform BCPB before resorting to a pleuroscopy. These results support BCPB as a relatively safe technique.
Lumbiganon, Pisake; Chongsomchai, Chompilas; Chumworathayee, Bundit; Thinkhamrop, Jadsada
2002-08-01
The objective of the study was to assess the diagnostic performance of the reagent strip in screening for asymptomatic bacteriuria in pregnant women using urine culture as a gold standard. This study comprised 204 asymptomatic pregnant women who attended their first antenatal care at Srinagarind Hospital, Khon Kaen University from April 1, 1999 to June 30, 1999. Women with symptoms of urinary tract infection, antibiotic treatment within the previous 7 days, pregnancy-induced hypertension, bleeding per vagina and history of urinary tract diseases were excluded. Urine specimens were collected by clean catched midstream urine technique for urinalysis, reagent strip test and urine culture. Diagnostic performance of reagent strip in terms of sensitivity, specificity, positive and negative predictive value was analyzed. Urine reagent strip test had a sensitivity of 13.9 per cent, a specificity of 95.6 per cent, a positive predictive value of 46.1 per cent, a negative predictive value of 80.6 per cent in detecting asymptomatic bacteriuria in pregnant women.
A preclustering-based ensemble learning technique for acute appendicitis diagnoses.
Lee, Yen-Hsien; Hu, Paul Jen-Hwa; Cheng, Tsang-Hsiang; Huang, Te-Chia; Chuang, Wei-Yao
2013-06-01
Acute appendicitis is a common medical condition, whose effective, timely diagnosis can be difficult. A missed diagnosis not only puts the patient in danger but also requires additional resources for corrective treatments. An acute appendicitis diagnosis constitutes a classification problem, for which a further fundamental challenge pertains to the skewed outcome class distribution of instances in the training sample. A preclustering-based ensemble learning (PEL) technique aims to address the associated imbalanced sample learning problems and thereby support the timely, accurate diagnosis of acute appendicitis. The proposed PEL technique employs undersampling to reduce the number of majority-class instances in a training sample, uses preclustering to group similar majority-class instances into multiple groups, and selects from each group representative instances to create more balanced samples. The PEL technique thereby reduces potential information loss from random undersampling. It also takes advantage of ensemble learning to improve performance. We empirically evaluate this proposed technique with 574 clinical cases obtained from a comprehensive tertiary hospital in southern Taiwan, using several prevalent techniques and a salient scoring system as benchmarks. The comparative results show that PEL is more effective and less biased than any benchmarks. The proposed PEL technique seems more sensitive to identifying positive acute appendicitis than the commonly used Alvarado scoring system and exhibits higher specificity in identifying negative acute appendicitis. In addition, the sensitivity and specificity values of PEL appear higher than those of the investigated benchmarks that follow the resampling approach. Our analysis suggests PEL benefits from the more representative majority-class instances in the training sample. According to our overall evaluation results, PEL records the best overall performance, and its area under the curve measure reaches 0.619. The PEL technique is capable of addressing imbalanced sample learning associated with acute appendicitis diagnosis. Our evaluation results suggest PEL is less biased toward a positive or negative class than the investigated benchmark techniques. In addition, our results indicate the overall effectiveness of the proposed technique, compared with prevalent scoring systems or salient classification techniques that follow the resampling approach. Copyright © 2013 Elsevier B.V. All rights reserved.
Intraoperative analysis of sentinel lymph nodes by imprint cytology for cancer of the breast.
Shiver, Stephen A; Creager, Andrew J; Geisinger, Kim; Perrier, Nancy D; Shen, Perry; Levine, Edward A
2002-11-01
The utilization of lymphatic mapping techniques for breast carcinoma has made intraoperative evaluation of sentinel lymph nodes (SLN) attractive, because axillary lymph node dissection can be performed during the initial surgery if the SLN is positive. The optimal technique for rapid SLN assessment has not been determined. Both frozen sectioning and imprint cytology are used for rapid intraoperative SLN evaluation. A retrospective review of the intraoperative imprint cytology results of 133 SLN mapping procedures from 132 breast carcinoma patients was performed. SLN were evaluated intraoperatively by bisecting the lymph node and making imprints of each cut surface. Imprints were stained with hematoxylin and eosin (H&E) and Diff-Quik. Permanent sections were evaluated with up to four H&E stained levels and cytokeratin immunohistochemistry. Imprint cytology results were compared with final histologic results. Sensitivity and specificity of imprint cytology were 56% and 100%, respectively, producing a 100% positive predictive value and 88% negative predictive value. Imprint cytology was significantly more sensitive for macrometastasis than micrometastasis 87% versus 22% (P = 0.00007). Of 13 total false negatives, 11 were found to be due to sampling error and 2 due to errors in intraoperative interpretation. Both intraoperative interpretation errors involved a diagnosis of lobular breast carcinoma. The sensitivity and specificity of imprint cytology are similar to that of frozen section evaluation. Imprint cytology is therefore a viable alternative to frozen sectioning when intraoperative evaluation is required. If SLN micrometastasis is used to determine the need for further lymphadenectomy, more sensitive intraoperative methods will be needed to avoid a second operation.
Flexible scintillator autoradiography for tumor margin inspection using 18F-FDG
NASA Astrophysics Data System (ADS)
Vyas, K. N.; Grootendorst, M.; Mertzanidou, T.; Macholl, S.; Stoyanov, D.; Arridge, S. R.; Tuch, D. S.
2018-03-01
Autoradiography potentially offers high molecular sensitivity and spatial resolution for tumor margin estimation. However, conventional autoradiography requires sectioning the sample which is destructive and labor-intensive. Here we describe a novel autoradiography technique that uses a flexible ultra-thin scintillator which conforms to the sample surface. Imaging with the flexible scintillator enables direct, high-resolution and high-sensitivity imaging of beta particle emissions from targeted radiotracers. The technique has the potential to identify positive tumor margins in fresh unsectioned samples during surgery, eliminating the processing time demands of conventional autoradiography. We demonstrate the feasibility of the flexible autoradiography approach to directly image the beta emissions from radiopharmaceuticals using lab experiments and GEANT-4 simulations to determine i) the specificity for 18F compared to 99mTc-labeled tracers ii) the sensitivity to detect signal from various depths within the tissue. We found that an image resolution of 1.5 mm was achievable with a scattering background and we estimate a minimum detectable activity concentration of 0.9 kBq/ml for 18F. We show that the flexible autoradiography approach has high potential as a technique for molecular imaging of tumor margins using 18F-FDG in a tumor xenograft mouse model imaged with a radiation-shielded EMCCD camera. Due to the advantage of conforming to the specimen, the flexible scintillator showed significantly better image quality in terms of tumor signal to whole-body background noise compared to rigid and optimally thick CaF2:Eu and BC400. The sensitivity of the technique means it is suitable for clinical translation.
Sensitive molecular diagnostics using surface-enhanced resonance Raman scattering (SERRS)
NASA Astrophysics Data System (ADS)
Faulds, Karen; Graham, Duncan; McKenzie, Fiona; MacRae, Douglas; Ricketts, Alastair; Dougan, Jennifer
2009-02-01
Surface enhanced resonance Raman scattering (SERRS) is an analytical technique with several advantages over competitive techniques in terms of improved sensitivity and multiplexing. We have made great progress in the development of SERRS as a quantitative analytical method, in particular for the detection of DNA. SERRS is an extremely sensitive and selective technique which when applied to the detection of labelled DNA sequences allows detection limits to be obtained which rival, and in most cases, are better than fluorescence. Here the conditions are explored which will enable the successful detection of DNA using SERRS. The enhancing surface which is used is crucial and in this case suspensions of nanoparticles were used as they allow quantitative behaviour to be achieved and allow analogous systems to current fluorescence based systems to be made. The aggregation conditions required to obtain SERRS of DNA are crucial and herein we describe the use of spermine as an aggregating agent. The nature of the label which is used, be it fluorescent, positively or negatively charged also effects the SERRS response and these conditions are again explored here. We have clearly demonstrated the ability to identify the components of a mixture of 5 analytes in solution by using two different excitation wavelengths and also of a 6-plex using data analysis techniques. These conditions will allow the use of SERRS for the detection of target DNA in a meaningful diagnostic assay.
Sow, Doudou; Dieng, Yémou; Haouchine, Djamal; Niang, Khadim; Niang, Thiane; Sylla, Khadime; Tine, Roger Clément; Ndiaye, Magatte; Ndiaye, Jean Louis; Faye, Babacar; Faye, Omar; Gaye, Oumar; Dieng, Thérèse; Izri, Arezki
2017-09-01
In the context of controlling intestinal parasites, accurate diagnosis is essential. Our objective was to evaluate the performance of new diagnostic kits compared to conventional microscopic methods in identifying intestinal parasites. Faeces collected in rural area in Senegal were subjected to several detection techniques. Thus, the sensitivity, specificity, positive and negative predictive values of new diagnostic techniques were compared to conventional merthiolate-iodine-formalin, conventional Bailenger and modified Ritchie. Furthermore, the kappa coefficient was calculated to evaluate the correlation between the new kit and those of modified Ritchie. Out of the 117 patients examined, 102 presented with a parasite, or prevalence of 87.1%. The Fumouze techniques proved to be as effective as the conventional methods in detecting flagellates and helminths with sensitivities ranging from 97 to 100%. However, conventional techniques were slightly more sensitive in identifying Endolimax nana and Blastocystis hominis . The correlation was nearly perfect (k = 0.83 and 1), respectively between Bailenger Fumouze, Iodesine Fumouze and modified Ritchie in identifying helminths while it was just acceptable (k = 0.27 and 0.28) in identifying B. hominis . The modified Ritchie technique routinely used in our laboratory remains a good diagnostic tool. However, the use of kit techniques was interesting when reading the pellet after concentration and the Colour KOP staining was a considerable contribution to the diagnosis of the vegetative forms. Therefore, it would be interesting to determine the cost of a stool test using Fumouze kit techniques to provide the most cost effective way.
NASA Technical Reports Server (NTRS)
Wolf, J. A.
1978-01-01
The Highly maneuverable aircraft technology (HIMAT) remotely piloted research vehicle (RPRV) uses cross-ship comparison monitoring of the actuator RAM positions to detect a failure in the aileron, canard, and elevator control surface servosystems. Some possible sources of nuisance trips for this failure detection technique are analyzed. A FORTRAN model of the simplex servosystems and the failure detection technique were utilized to provide a convenient means of changing parameters and introducing system noise. The sensitivity of the technique to differences between servosystems and operating conditions was determined. The cross-ship comparison monitoring method presently appears to be marginal in its capability to detect an actual failure and to withstand nuisance trips.
Emerging applications of fluorescence spectroscopy in medical microbiology field.
Shahzad, Aamir; Köhler, Gottfried; Knapp, Martin; Gaubitzer, Erwin; Puchinger, Martin; Edetsberger, Michael
2009-11-26
There are many diagnostic techniques and methods available for diagnosis of medically important microorganisms like bacteria, viruses, fungi and parasites. But, almost all these techniques and methods have some limitations or inconvenience. Most of these techniques are laborious, time consuming and with chances of false positive or false negative results. It warrants the need of a diagnostic technique which can overcome these limitations and problems. At present, there is emerging trend to use Fluorescence spectroscopy as a diagnostic as well as research tool in many fields of medical sciences. Here, we will critically discuss research studies which propose that Fluorescence spectroscopy may be an excellent diagnostic as well as excellent research tool in medical microbiology field with high sensitivity and specificity.
Schares, G; Koethe, M; Bangoura, B; Geuthner, A-C; Randau, F; Ludewig, M; Maksimov, P; Sens, M; Bärwald, A; Conraths, F J; Villena, I; Aubert, D; Opsteegh, M; Van der Giessen, J
2018-05-19
Chickens, especially if free-range, are frequently exposed to Toxoplasma gondii, and may represent an important reservoir for T. gondii. Poultry products may pose a risk to humans, when consumed undercooked. In addition, chickens are regarded as sensitive indicators for environmental contamination with T. gondii oocysts and have been used as sentinels. The aim of the present study was to determine the suitability of commonly used antibody detection methods, i.e. the modified agglutination test (MAT), IFAT and ELISA to detect T. gondii-infected chickens. Samples of experimentally and naturally infected chickens were used. The infection state of all chickens was determined by Magnetic-Capture (MC-) real-time PCR (RT PCR). Naturally exposed chickens were additionally examined by mouse bioassay and conventional RT PCR on acidic pepsin digests (PD-RT PCR). Blood serum and meat juice of various sources were tested for antibodies to T. gondii. In naturally infected chickens, there was substantial agreement between the mouse bioassay and MC-RT PCR or the mouse bioassay and conventional PD-RT PCR. PD-RT PCR was slightly more sensitive than MC-RT PCR, as all (26/26) bioassay-positive chickens also tested positive in at least one of the tissues tested (heart, drumstick). By MC-RT PCR, 92.3% (24/26) of the naturally infected bioassay-positive chickens were positive. The diagnostic sensitivity of MC-RT PCR was clearly related to the organ examined. Based on a quantitative assessment of the MC-RT PCR results in experimentally infected chickens, brain and heart tissues harbored an at least 100 times higher parasite concentration than breast, thigh or drumstick musculature. In naturally infected chickens, only three out of 24 birds, which were MC-RT PCR-positive in heart samples, also tested positive in drumstick musculature. Under experimental conditions, the agreement between MC-RT PCR and the serological techniques revealed 100% diagnostic sensitivity and specificity. Under field conditions, examinations of sera by ELISA, IFAT and MAT showed good performance in identifying chickens that were positive in either a mouse bioassay, MC-RT PCR, or PD-RT PCR as illustrated by diagnostic sensitivities of 87.5%, 87.5% and 65.2%, respectively, and diagnostic specificities of 86.2%, 82.8% and 100%, respectively. The examination of meat juice samples from breast, drumstick or heart musculature revealed similar or even better results in the ELISA. The results in the MAT with meat juice from breast musculature were less consistent than those of ELISA and IFAT because a number of negative chickens tested false-positive in the MAT. The MAT performed similar to ELISA and IFAT when applied to test meat juice samples collected from heart, thigh or drumstick musculature. Copyright © 2018 Australian Society for Parasitology. Published by Elsevier Ltd. All rights reserved.
Deng, S; Zhou, Z; de Hoog, G S; Wang, X; Abliz, P; Sun, J; Najafzadeh, M J; Pan, W; Lei, W; Zhu, S; Hasimu, H; Zhang, P; Guo, Y; Deng, D; Liao, W
2015-12-01
Tinea capitis is very common in Western China, with the most widespread aetiological agent being Trichophyton violaceum, while Microsporum canis is prevalent in the remainder of China. Conventional diagnostics and internal transcribed spacer (ITS) sequencing analyses have proven relatively limited due to the close phylogenetic relationship of anthropophilic dermatophytes. Therefore, alternative molecular tools with sufficient specificity, reproducibility and sensitivity are necessary. To evaluate two molecular techniques [multiplex ligation-dependent probe amplification (MLPA) and rolling circle amplification (RCA)] for rapid detection of the aetiological agents of tinea capitis, T. violaceum and M. canis. Probes of RCA and MLPA were designed with target sequences in the rDNA ITS gene region. Strains tested consist of 31 T. violaceum, 22 M. canis and 24 reference strains of species that are taxonomically close to the target species. The specificity and reproducibility of RCA and MLPA in detection of T. violaceum and M. canis were both 100% in both species. Sensitivity testing showed that RCA was positive at concentrations down to 1·68 × 10(6) copies of DNA in the TvioRCA probe, and 2·7 × 10(8) copies of DNA in McRCA. MLPA yielded positive results at concentrations of DNA down to 1·68 × 10(1) copies in the TvioMLPA probe and 2·7 × 10(2) in McMLPA. The two techniques were sufficiently specific and sensitive for discriminating the target DNA of T. violaceum and M. canis from that of closely related dermatophytes. RCA and MLPA are advantageous in their reliability and ease of operation compared with standard polymerase chain reaction and conventional methods. © 2015 British Association of Dermatologists.
Jamshidi Makiani, Mahin; Davoodian, Parivash; Baghershiroodi, Mahnaz; Nejatizadeh, Abdol Azim; Fakkhar, Farideh; Zangeneh, Mehrangiz; Jahangiri, Nadia
2016-08-01
While tuberculosis (TB) can be diagnosed by microscopy and culture, the sensitivity of Ziehl-Neelsen staining is variable and culture results require 4 - 8 weeks to be determined. Polymerase chain reaction (PCR) and its modifications, including nested PCR, might be promising methods for the rapid diagnosis of TB. This study aimed to evaluate the performance of nested PCR on urine samples of human immunodeficiency virus (HIV)-positive and -negative patients with different manifestations of clinical TB. In a prospective study, three early-morning urine samples from 100 patients with pulmonary TB (PTB) or extrapulmonary TB (EPTB) were evaluated using a molecular target with insertion element IS6110, specific to the Mycobacterium tuberculosis genome, and nested PCR was performed. The results were analyzed with SPSS version 22. A total of 100 patients, including 74 (74%) with PTB and 26 (26%) with EPTB, were enrolled. Positive smears were seen in 38 patients (38%). Lymph nodes were the most commonly involved organ in 14 of the 26 (53.8%) EPTB patients (13.5%). Seven (23.1%) of the EPTB patients were HIV-positive. Urine PCR was positive in only 28 patients (28%). Seven HIV-positive patients with PTB showed positive urine PCR results. Moreover, PCR results were positive in only one of the seven HIV-positive subjects with EPTB. Positive PCR results were found in 20 of the 73 HIV-negative patients (27.4%) and in 8 of the 27 HIV-positive patients (29.6%). Therefore, there was no significant difference between the HIV-negative and HIV-positive patients for urine PCR (sensitivity 29.6%, specificity 72.6%; positive and negative predictive values 28% and 72%, respectively; P = 0.138). Nested PCR showed the same sensitivity in HIV-positive and HIV-negative patients. It can be applied as a rapid technique for the diagnosis of TB.
Llop, Pablo; Bonaterra, Anna; Peñalver, Javier; López, María M.
2000-01-01
A novel method, which involves a nested PCR in a single closed tube, was developed for the sensitive detection of Erwinia amylovora in plant material. The external and internal primer pairs used had different annealing temperatures and directed the amplification of a specific DNA fragment from plasmid pEA29. The procedure involved two consecutive PCRs, the first of which was performed at a higher annealing temperature that allowed amplification only by the external primer pair. Using pure cultures of E. amylovora, the sensitivity of the nested PCR in one tube was similar to that of a standard nested PCR in two tubes. The specificity and sensitivity were greater than those of standard PCR procedures that used a single primer pair. The presence of inhibitors in plant material, very common in E. amylovora hosts, is overcome with this system in combination with a simple DNA extraction protocol because it eliminates many of the inhibitory compounds. In addition, it needs a very small sample volume (1 μl of DNA extracted). With 83 samples of naturally infected material, this method achieved better results than any other PCR technique: standard PCR detected 55% of positive samples, two-tube nested PCR detected 71% of positive samples, and nested PCR in a single closed tube detected 78% of positive samples. When analyzing asymptomatic plant material, the number of positive samples detected by the developed nested PCR was also the highest, compared with the PCR protocols indicated previously (17, 20, and 25% of 251 samples analyzed, respectively). This method is proposed for the detection of endophytic and epiphytic populations of E. amylovora in epidemiological studies and for routine use in quarantine surveys, due to its high sensitivity, specificity, speed, and simplicity. PMID:10788384
Pinilla, I; Gómez-León, N; Del Campo-Del Val, L; Hernandez-Maraver, D; Rodríguez-Vigil, B; Jover-Díaz, R; Coya, J
2011-10-01
The aim of this paper was to compare the accuracy of contrast-enhanced computed tomography (CT), positron emission tomography (PET), unenhanced low-dose PET/CT (LD-PET/CT) and full-dose enhanced PET/CT (FD-PET/CT) for the initial staging of lymphoma. One hundred and one lymphoma patients were examined by [18F]FDG-PET/CT including unenhanced low-dose CT and enhanced full-dose CT. Each modality of PET/CT was evaluated by a nuclear medicine physician and a radiologist unaware of the other modality, while the CT and PET images were interpreted separately by another independent radiologist and nuclear medicine physician respectively. The nodal and extranodal lesions detected by each technique were compared with a reference standard. For nodal assessment, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), and negative LR (LR-) of LD-PET/CT were 97%, 96%, 98%, 95%, 26 and 0.02 respectively, and those of FD-PET/CT were 97%, 97%, 98%, 95%, 36 and 0.02. These results were significantly better than those of PET (sensitivity 82%, specificity 81%, PPV 88%, NPV 72%, LR+ 4.3, LR- 0.21). Likewise, both PET/CT displayed a higher sensitivity, NPV and LR- than CT (91%, 84%, 0.1 respectively). For organ evaluation, both modalities of PET/CT also had significantly better sensitivity and NPV than that of PET (LD-PET/CT: sensitivity 92%, NPV 90%; FD-PET/CT sensitivity 94%, NPV 92%; PET: sensitivity 70%, NPV 69%). The sensitivity, specificity, PPV and NPV for bone marrow involvement were 29%, 84%, 45% and 72% respectively for PET, and 29%, 90%, 56%, and 74% for both, LD-PET/CT, and FD-PET/CT. No significant differences were found between LD-PET/CT and FD-PET/CT, but FD-PET/CT detected important incidental findings in 5.9% of patients. PET/CT is an accurate technique for the initial staging of lymphomas without significant differences between LD-PET/CT and FD-PET/CT. FD-PET/CT detects relevant incidental findings that are missed on LD-PET/CT.
Ackerman, L K; Noonan, G O; Begley, T H
2009-12-01
The ambient ionization technique direct analysis in real time (DART) was characterized and evaluated for the screening of food packaging for the presence of packaging additives using a benchtop mass spectrometer (MS). Approximate optimum conditions were determined for 13 common food-packaging additives, including plasticizers, anti-oxidants, colorants, grease-proofers, and ultraviolet light stabilizers. Method sensitivity and linearity were evaluated using solutions and characterized polymer samples. Additionally, the response of a model additive (di-ethyl-hexyl-phthalate) was examined across a range of sample positions, DART, and MS conditions (temperature, voltage and helium flow). Under optimal conditions, molecular ion (M+H+) was the major ion for most additives. Additive responses were highly sensitive to sample and DART source orientation, as well as to DART flow rates, temperatures, and MS inlet voltages, respectively. DART-MS response was neither consistently linear nor quantitative in this setting, and sensitivity varied by additive. All additives studied were rapidly identified in multiple food-packaging materials by DART-MS/MS, suggesting this technique can be used to screen food packaging rapidly. However, method sensitivity and quantitation requires further study and improvement.
Spatial and Temporal Monitoring Resolutions for CO2 Leakage Detection at Carbon Storage Sites
NASA Astrophysics Data System (ADS)
Yang, Y. M.; Dilmore, R. M.; Daley, T. M.; Carroll, S.; Mansoor, K.; Gasperikova, E.; Harbert, W.; Wang, Z.; Bromhal, G. S.; Small, M.
2016-12-01
Different leakage monitoring techniques offer different strengths in detection sensitivity, coverage, feedback time, cost, and technology availability, such that they may complement each other when applied together. This research focuses on quantifying the spatial coverage and temporal resolution of detection response for several geophysical remote monitoring and direct groundwater monitoring techniques for an optimal monitoring plan for CO2 leakage detection. Various monitoring techniques with different monitoring depths are selected: 3D time-lapse seismic survey, wellbore pressure, groundwater chemistry and soil gas. The spatial resolution in terms of leakage detectability is quantified through the effective detection distance between two adjacent monitors, given the magnitude of leakage and specified detection probability. The effective detection distances are obtained either from leakage simulations with various monitoring densities or from information garnered from field test data. These spatial leakage detection resolutions are affected by physically feasible monitoring design and detection limits. Similarly, the temporal resolution, in terms of leakage detectability, is quantified through the effective time to positive detection of a given size of leak and a specified detection probability, again obtained either from representative leakage simulations with various monitoring densities or from field test data. The effective time to positive detection is also affected by operational feedback time (associated with sampling, sample analysis and data interpretation), with values obtained mainly through expert interviews and literature review. In additional to the spatial and temporal resolutions of these monitoring techniques, the impact of CO2 plume migration speed and leakage detection sensitivity of each monitoring technique are also discussed with consideration of how much monitoring is necessary for effective leakage detection and how these monitoring techniques can be better combined in a time-space framework. The results of the spatial and temporal leakage detection resolutions for several geophysical monitoring techniques and groundwater monitoring are summarized to inform future monitoring designs at carbon storage sites.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zuro, D; Hui, S
Purpose: Totals Marrow Irradiation (TMI) is a highly focused radiation delivery to the human skeleton structure therefore requiring a high amount of precision and accuracy for a quality treatment. Not much is known on how the patient position varies across multiple treatment fractions and how that positioning impacts the dose delivery. Currently TMI is studied as an international collaboration with multiple centers around the world; however, many of these centers used different pretreatment techniques. The goal of this work is to measure the accuracy of patient positioning, its impact on dose delivery and compare the impact of each technique formore » multiple institutions. Methods: Using Tomotherapy pretreatment MVCTs and the planning KVCTs measurements are made of the 3D setup uncertainties of the TMI treatment. Then, using the dose and plan files of the treatment impact of patient position on dose can be measured. Measurement of organ deformation and center of mass change were done using the Velocity AI program from Varian. We are looking at four the boney targets (skull, spine, pelvis, and femur) and three key sensitive tissues (eyes, lungs, kidneys). Results: Position measurements have been made for 3 different institutions using 3 different pre-treatment techniques. Comparing the translation motion we can observe the greatest change in the Y and Z direction of patient set up. For intra-fractional motion the shoulder and clavicle represent the greatest potential for motion and therefore most likely to have a dose change. Conclusion: All centers use different techniques for their treatment and this study shows that these techniques do not produce the same pretreatment results. We hope to expand this study further. Currently we have 3 centers participating in this study with more centers joining every day.« less
NASA Technical Reports Server (NTRS)
Desantis, A.
1994-01-01
In this paper the approximation problem for a class of optimal compensators for flexible structures is considered. The particular case of a simply supported truss with an offset antenna is dealt with. The nonrational positive real optimal compensator transfer function is determined, and it is proposed that an approximation scheme based on a continued fraction expansion method be used. Comparison with the more popular modal expansion technique is performed in terms of stability margin and parameters sensitivity of the relative approximated closed loop transfer functions.
Pongsachareonnont, Pear; Honglertnapakul, Worawalun; Chatsuwan, Tanittha
2017-02-21
Identification of bacterial pathogens in endophthalmitis is important to inform antibiotic selection and treatment decisions. Hemoculture bottles and polymerase chain reaction (PCR) analysis have been proposed to offer good detection sensitivity. This study compared the sensitivity and accuracy of a blood culture system, a PCR approach, and conventional culture methods for identification of causative bacteria in cases of acute endophthalmitis. Twenty-nine patients with a diagnosis of presumed acute bacterial endophthalmitis who underwent vitreous specimen collection at King Chulalongkorn Memorial Hospital were enrolled in this study. Forty-one specimens were collected. Each specimen was divided into three parts, and each part was analyzed using one of three microbial identification techniques: conventional plate culture, blood culture, and polymerase chain reaction and sequencing. The results of the three methods were then compared. Bacteria were identified in 15 of the 41 specimens (36.5%). Five (12.2%) specimens were positive by conventional culture methods, 11 (26.8%) were positive by hemoculture, and 11 (26.8%) were positive by PCR. Cohen's kappa analysis revealed p-values for conventional methods vs. hemoculture, conventional methods vs. PCR, and hemoculture vs. PCR of 0.057, 0.33, and 0.009, respectively. Higher detection rates of Enterococcus faecalis were observed for hemoculture and PCR than for conventional methods. Blood culture bottles and PCR detection may facilitate bacterial identification in cases of presumed acute endophthalmitis. These techniques should be used in addition to conventional plate culture methods because they provide a greater degree of sensitivity than conventional plate culture alone for the detection of specific microorganisms such as E. faecalis. Thai Clinical Trial Register No. TCTR20110000024 .
Porwancher, Richard B.; Hagerty, C. Greg; Fan, Jianqing; Landsberg, Lisa; Johnson, Barbara J. B.; Kopnitsky, Mark; Steere, Allen C.; Kulas, Karen; Wong, Susan J.
2011-01-01
The Centers for Disease Control and Prevention currently recommends a 2-tier serologic approach to Lyme disease laboratory diagnosis, comprised of an initial serum enzyme immunoassay (EIA) for antibody to Borrelia burgdorferi followed by supplementary IgG and IgM Western blotting of EIA-positive or -equivocal samples. Western blot accuracy is limited by subjective interpretation of weakly positive bands, false-positive IgM immunoblots, and low sensitivity for detection of early disease. We developed an objective alternative second-tier immunoassay using a multiplex microsphere system that measures VlsE1-IgG and pepC10-IgM antibodies simultaneously in the same sample. Our study population comprised 79 patients with early acute Lyme disease, 82 patients with early-convalescent-phase disease, 47 patients with stage II and III disease, 34 patients post-antibiotic treatment, and 794 controls. A bioinformatic technique called partial receiver-operator characteristic (ROC) regression was used to combine individual antibody levels into a single diagnostic score with a single cutoff; this technique enhances test performance when a high specificity is required (e.g., ≥95%). Compared to Western blotting, the multiplex assay was equally specific (95.6%) but 20.7% more sensitive for early-convalescent-phase disease (89.0% versus 68.3%, respectively; 95% confidence interval [95% CI] for difference, 12.1% to 30.9%) and 12.5% more sensitive overall (75.0% versus 62.5%, respectively; 95% CI for difference, 8.1% to 17.1%). As a second-tier test, a multiplex assay for VlsE1-IgG and pepC10-IgM antibodies performed as well as or better than Western blotting for Lyme disease diagnosis. Prospective validation studies appear to be warranted. PMID:21367982
Gura, Sigalit; Guerra-Diaz, Patricia; Lai, Hanh; Almirall, José R
2009-07-01
Trace detection of illicit drugs challenges the scientific community to develop improved sensitivity and selectivity in sampling and detection techniques. Ion mobility spectrometry (IMS) is one of the prominent trace detectors for illicit drugs and explosives, mostly due to its portability, high sensitivity and fast analysis. Current sampling methods for IMS rely on wiping suspected surfaces or withdrawing air through filters to collect particulates. These methods depend greatly on the particulates being bound onto surfaces or having sufficient vapour pressure to be airborne. Many of these compounds are not readily available in the headspace due to their low vapour pressure. This research presents a novel SPME device for enhanced air sampling and shows the use of optimized IMS by genetic algorithms to target volatile markers and/or odour signatures of illicit substances. The sampling method was based on unique static samplers, planar substrates coated with sol-gel polydimethyl siloxane (PDMS) nanoparticles, also known as planar solid-phase microextraction (PSPME). Due to its surface chemistry, high surface area and capacity, PSPME provides significant increases in sensitivity over conventional fibre SPME. The results show a 50-400 times increase in the detection capacity for piperonal, the odour signature of 3,4-methylenedioxymethamphetamine (MDMA). The PSPME-IMS technique was able to detect 600 ng of piperonal in a 30 s extraction from a quart-sized can containing 5 MDMA tablets, while detection using fibre SPME-IMS was not attainable. In a blind study of six cases suspected to contain varying amounts of MDMA in the tablets, PSPME-IMS successfully detected five positive cases and also produced no false positives or false negatives. One positive case had minimal amounts of MDMA resulting in a false negative response for fibre SPME-IMS.
Granados, U; Fuster, D; Soriano, A; García, S; Bori, G; Martínez, J C; Mayoral, M; Perlaza, P; Tomás, X; Pons, F
2015-01-01
To evaluate the impact of the angioscintigrapy of the three phase bone scan as screening method to rule out infection of the hip and knee prosthesis prior to performing the (99m)Tc-HMPAO leukocyte scintigraphy. A total of 120 (70 women, 50 men; mean age 71±11years) with clinical suspicion of hip (n=63) or knee (n=57) infection of the prosthesis and clinical suspicion of infection were evaluated prospectively. All patients underwent three-phase bone scan (angioscintigraphy, vascular and bone phase) and (99m)Tc-HMPAO-labelled white blood cell scintigraphy. Final diagnosis of infection was made by microbiological documentation or clinical follow-up for at least 12months. Eighteen out of 120 patients were diagnosed of infection of hip prosthesis (n=10) or knee prosthesis (n=8). The angioscintigraphy was positive in 15/18 infected cases and in 21/102 of the non-infected cases with a sensitivity of 83%, specificity of 79% and negative predictive value of 97%. Sensitivity and specificity of (99m)Tc-HMPAO leukocyte scintigraphy were 72% and 95%, respectively. If the leukocyte labeled scintigraphies had been used exclusively for patients with positive angioscintigraphy, this would have saved up to 70% of the (99m)Tc-HMPAO leukocyte scintigraphies performed. There were no cases of infection with positive labeled leukocyte scintigraphy and negative angioscintigraphy. Angioscintigraphy (blood flow phase of bone scan) is a useful technique for screening for hip and knee joint prosthesis infection, significantly reducing the need for (99m)Tc-HMPAO leukocyte scintigraphy without affecting the sensitivity of the technique. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.
Treglia, Giorgio; Cason, Ernesto; Cortelli, Pietro; Gabellini, Anna; Liguori, Rocco; Bagnato, Antonio; Giordano, Alessandro; Fagioli, Giorgio
2014-01-01
To compare myocardial sympathetic imaging using (123)I-Metaiodobenzylguanidine (MIBG) scintigraphy and striatal dopaminergic imaging using (123)I-Ioflupane (FP-CIT) single photon emission computed tomography (SPECT) in patients with suspected Lewy body diseases (LBD). Ninety-nine patients who performed both methods within 2 months for differential diagnosis between Parkinson's disease (PD) and other parkinsonism (n = 68) or between dementia with Lewy bodies (DLB) and other dementia (n = 31) were enrolled. Sensitivity, specificity, accuracy, positive and negative predictive values of both methods were calculated. For (123) I-MIBG scintigraphy, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 83%, 79%, 82%, 86%, and 76%, respectively. For (123)I-FP-CIT SPECT, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 93%, 41%, 73%, 71%, and 80%, respectively. There was a statistically significant difference between these two methods in patients without LBD, but not in patients with LBD. LBD usually present both myocardial sympathetic and striatal dopaminergic impairments. (123)I-FP-CIT SPECT presents high sensitivity in the diagnosis of LBD; (123)I-MIBG scintigraphy may have a complementary role in differential diagnosis between PD and other parkinsonism. These scintigraphic methods showed similar diagnostic accuracy in differential diagnosis between DLB and other dementia. Copyright © 2012 by the American Society of Neuroimaging.
Sarquiz-Martínez, Brenda; González-Bonilla, César R; Santacruz-Tinoco, Clara Esperanza; Muñoz-Medina, José E; Pardavé-Alejandre, Héctor D; Barbosa-Cabrera, Elizabeth; Ramírez-González, José Ernesto; Díaz-Quiñonez, José Alberto
2017-01-01
Enterovirus (EV) and herpes simplex virus 1 and 2 (HSV1 and HSV2) are the main etiologic agents of central nervous system infections. Early laboratory confirmation of these infections is performed by viral culture of the cerebrospinal fluid (CSF), or the detection of specific antibodies in serum (e.g., HSV). The sensitivity of viral culture ranges from 65 to 75%, with a recovery time varying from 3 to 10 days. Serological tests are faster and easy to carry out, but they exhibit cross-reactivity between HSV1 and HSV2. Although molecular techniques are more sensitive (sensitivity >95%), they are more expensive and highly susceptible to cross-contamination. A real-time RT-PCR for the detection of EV, HSV1, and HSV2 was compared with end-point nested PCR. We tested 87 CSF samples of patients with a clinical diagnosis of viral meningitis or encephalitis. Fourteen samples were found to be positive by RT-PCR, but only 8 were positive by end-point PCR. The RT-PCR showed a specificity range of 94-100%, the negative predictive value was 100%, and the positive predictive value was 62, 100, and 28% for HSV1, HSV2, and EV, respectively. Real-time RT-PCR detected EV, HSV1, and HSV2 with a higher sensitivity and specificity than end-point nested RT-PCR. © 2017 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Janicki, Łukasz; Ramírez-López, Manolo; Misiewicz, Jan; Cywiński, Grzegorz; Boćkowski, Michał; Muzioł, Grzegorz; Chèze, Caroline; Sawicka, Marta; Skierbiszewski, Czesław; Kudrawiec, Robert
2016-05-01
Ga-polar, N-polar, and nonpolar m-plane GaN UN+ structures have been examined in air and vacuum ambient by contactless electroreflectance (CER). This technique is very sensitive to the surface electric field that varies with the Fermi level position at the surface. For UN+ GaN structures [i.e., GaN (undoped)/GaN (n-type)/substrate], a homogeneous built-in electric field is expected in the undoped GaN layer that is manifested by Franz-Keldysh oscillation (FKO) in CER spectra. A clear change in FKO has been observed in CER spectra for N-polar and nonpolar m-plane structures when changing from air to vacuum ambient. This means that those surfaces are very sensitive to ambient atmosphere. In contrast to that, only a small change in FKO can be seen in the Ga-polar structure. This clearly shows that the ambient sensitivity of the Fermi level position at the GaN surface varies with the crystallographic orientation and is very high for N-polar and nonpolar m-plane surfaces. This feature of the N-polar and nonpolar m-plane surfaces can be very important for GaN-based devices grown on these crystallographic orientations and can be utilized in some of the devices, e.g., sensors.
NASA Astrophysics Data System (ADS)
Oudini, N.; Sirse, N.; Taccogna, F.; Ellingboe, A. R.; Bendib, A.
2018-05-01
We propose a new technique for diagnosing negative ion properties using Langmuir probe assisted pulsed laser photo-detachment. While the classical technique uses a laser pulse to convert negative ions into electron-atom pairs and a positively biased Langmuir probe tracking the change of electron saturation current, the proposed method uses a negatively biased Langmuir probe to track the temporal evolution of positive ion current. The negative bias aims to avoid the parasitic electron current inherent to probe tip surface ablation. In this work, we show through analytical and numerical approaches that, by knowing electron temperature and performing photo-detachment at two different laser wavelengths, it is possible to deduce plasma electronegativity (ratio of negative ion to electron densities) α, and anisothermicity (ratio of electron to negative ion temperatures) γ-. We present an analytical model that links the change in the collected positive ion current to plasma electronegativity and anisothermicity. Particle-In-Cell simulation is used as a numerical experiment covering a wide range of α and γ- to test the new analysis technique. The new technique is sensitive to α in the range 0.5 < α < 10 and yields γ- for large α, where negative ion flux affects the probe sheath behavior, typically α > 1.
V, Pavana Jyothi; S, Akila; Selvan, Malini K; Naidu, Hariprasad; Raghunathan, Shwethaa; Kota, Sathish; Sundaram, R C Raja; Rana, Samir Kumar; Raj, G Dhinakar; Srinivasan, V A; Mohana Subramanian, B
2016-12-01
Canine parvovirus (CPV) is a non-enveloped single stranded DNA virus with an icosahedral capsid. Mini-sequencing based CPV typing was developed earlier to detect and differentiate all the CPV types and FPV in a single reaction. This technique was further evaluated in the present study by performing the mini-sequencing directly from fecal samples which avoided tedious virus isolation steps by cell culture system. Fecal swab samples were collected from 84 dogs with enteritis symptoms, suggestive of parvoviral infection from different locations across India. Seventy six of these samples were positive by PCR; the subsequent mini-sequencing reaction typed 74 of them as type 2a virus, and 2 samples as type 2b. Additionally, 25 of the positive samples were typed by cycle sequencing of PCR products. Direct CPV typing from fecal samples using mini-sequencing showed 100% correlation with CPV typing by cycle sequencing. Moreover, CPV typing was achieved by mini-sequencing even with faintly positive PCR amplicons which was not possible by cycle sequencing. Therefore, the mini-sequencing technique is recommended for regular epidemiological follow up of CPV types, since the technique is rapid, highly sensitive and high capacity method for CPV typing. Copyright © 2016. Published by Elsevier B.V.
Calvani, Nichola Eliza Davies; Windsor, Peter Andrew; Bush, Russell David; Šlapeta, Jan
2017-09-01
Fasciolosis, due to Fasciola hepatica and Fasciola gigantica, is a re-emerging zoonotic parasitic disease of worldwide importance. Human and animal infections are commonly diagnosed by the traditional sedimentation and faecal egg-counting technique. However, this technique is time-consuming and prone to sensitivity errors when a large number of samples must be processed or if the operator lacks sufficient experience. Additionally, diagnosis can only be made once the 12-week pre-patent period has passed. Recently, a commercially available coprological antigen ELISA has enabled detection of F. hepatica prior to the completion of the pre-patent period, providing earlier diagnosis and increased throughput, although species differentiation is not possible in areas of parasite sympatry. Real-time PCR offers the combined benefits of highly sensitive species differentiation for medium to large sample sizes. However, no molecular diagnostic workflow currently exists for the identification of Fasciola spp. in faecal samples. A new molecular diagnostic workflow for the highly-sensitive detection and quantification of Fasciola spp. in faecal samples was developed. The technique involves sedimenting and pelleting the samples prior to DNA isolation in order to concentrate the eggs, followed by disruption by bead-beating in a benchtop homogeniser to ensure access to DNA. Although both the new molecular workflow and the traditional sedimentation technique were sensitive and specific, the new molecular workflow enabled faster sample throughput in medium to large epidemiological studies, and provided the additional benefit of speciation. Further, good correlation (R2 = 0.74-0.76) was observed between the real-time PCR values and the faecal egg count (FEC) using the new molecular workflow for all herds and sampling periods. Finally, no effect of storage in 70% ethanol was detected on sedimentation and DNA isolation outcomes; enabling transport of samples from endemic to non-endemic countries without the requirement of a complete cold chain. The commercially-available ELISA displayed poorer sensitivity, even after adjustment of the positive threshold (65-88%), compared to the sensitivity (91-100%) of the new molecular diagnostic workflow. Species-specific assays for sensitive detection of Fasciola spp. enable ante-mortem diagnosis in both human and animal settings. This includes Southeast Asia where there are potentially many undocumented human cases and where post-mortem examination of production animals can be difficult. The new molecular workflow provides a sensitive and quantitative diagnostic approach for the rapid testing of medium to large sample sizes, potentially superseding the traditional sedimentation and FEC technique and enabling surveillance programs in locations where animal and human health funding is limited.
Position-sensitive scanning fluorescence correlation spectroscopy.
Skinner, Joseph P; Chen, Yan; Müller, Joachim D
2005-08-01
Fluorescence correlation spectroscopy (FCS) uses a stationary laser beam to illuminate a small sample volume and analyze the temporal behavior of the fluorescence fluctuations within the stationary observation volume. In contrast, scanning FCS (SFCS) collects the fluorescence signal from a moving observation volume by scanning the laser beam. The fluctuations now contain both temporal and spatial information about the sample. To access the spatial information we synchronize scanning and data acquisition. Synchronization allows us to evaluate correlations for every position along the scanned trajectory. We use a circular scan trajectory in this study. Because the scan radius is constant, the phase angle is sufficient to characterize the position of the beam. We introduce position-sensitive SFCS (PSFCS), where correlations are calculated as a function of lag time and phase. We present the theory of PSFCS and derive expressions for diffusion, diffusion in the presence of flow, and for immobilization. To test PSFCS we compare experimental data with theory. We determine the direction and speed of a flowing dye solution and the position of an immobilized particle. To demonstrate the feasibility of the technique for applications in living cells we present data of enhanced green fluorescent protein measured in the nucleus of COS cells.
Fazii, P; Ciancaglini, E; Riario Sforza, G
2002-05-01
The aim of this study was to evaluate a differential staining method to distinguish gram-positive from gram-negative bacteria in fluorescence. The method is based on two fluorochromes, one acting in the wavelength of red, i.e. the acridine orange, and another acting in the wavelength of green, i.e. the fluorescein. With this method, gram-positive bacteria appear yellow and gram-negative bacteria appear green. In view of the importance of a rapid aetiological diagnosis in cases of septicaemia, the differential staining method in fluorescence was compared with Gram stain for the detection of bacteria in blood. Of 5,820 blood cultures entered into the study and identified by the Bactec 9120 fluorescent series instrument (Becton Dickinson Europe, France), 774 were positive. Of the 774 positive cultures, 689 yielded only a single organism. The differential staining method in fluorescence detected 626 of the 689 cultures, while Gram stain detected 468. On the basis of these results, the sensitivity of the differential staining method in fluorescence was 90.9%, while that of Gram stain was 67.9%. The difference between the two methods was statistically significant ( P<0.001). The differential fluorescent staining method was more sensitive than Gram stain in the detection of bacteria in blood cultures during the incubation period. This technique provides a rapid, simple and highly sensitive staining method that can be used in conjunction with subculture methods. Whereas subculture requires an incubation period of 18-24 h, the fluorescent staining technique can detect bacteria on the same day that smears are prepared and examined. The differential fluorescent staining method was also evaluated for its ability to detect microorganisms in cerebrospinal fluid and other clinical specimens. The microorganisms were easily detected, even when bacterial counts in the specimens were low.
Rapid Detection and Identification of Respiratory Viruses by Direct Immunofluorescence
D'Alessio, Donn; Williams, Stanley; Dick, Elliot C.
1970-01-01
The use of fluorescein-conjugated antiserum against respiratory syncytial (RS) and parainfluenza 1 and 3 viruses was compared with conventional techniques in the rapid detection of virus in tissue cultures inoculated with pharyngeal specimens known to contain these viruses. Twenty-three specimens were tested: 9 RS, 8 parainfluenza 1, and 6 parainfluenza 3. The fluorescent-antibody technique (FA) detected virus in 52% of the tissue cultures in 24 hr, and, by 72 hr, 22 of the 23 cultures were FA-positive whereas only 5 were positive by conventional techniques. Additionally, conjugated antisera were prepared against herpes simplex, influenza A2, and adenovirus type 5. All conjugates stained only the homologous virus and were 100- to 10,000-fold more sensitive than conventional techniques in detecting descending dilutions of virus inocula by 24 hr. With the procedures described, several antisera could be conjugated and ready for use within 24 hr. Serum fractionation was by ammonium sulfate precipitation, and with the procedure outlined virtually complete recovery of the globulin fraction and elimination of all of the albumin were accomplished. Images PMID:4098101
Pell, Gaby S; Abbott, David F; Fleming, Steven W; Prichard, James W; Jackson, Graeme D
2006-05-01
The characteristics of an MRI technique that could be used for direct detection of neuronal activity are investigated. It was shown that magnitude imaging using echo planar imaging can detect transient local currents. The sensitivity of this method was thoroughly investigated. A partial k-space EPI acquisition with homodyne reconstruction was found to increase the signal change. A unique sensitivity to the position of the current pulse within the imaging sequence was demonstrated with the greatest signal change occurring when the current pulse coincides with the acquisition of the center lines of k-space. The signal change was shown to be highly sensitive to the spatial position of the current conductor relative to the voxel. Furthermore, with the use of optimization of spatial and temporal placement of the current pulse, the level of signal change obtained at this lower limit of current detectability was considerably magnified. It was possible to detect a current of 1.7 microA applied for 20 ms with an imaging time of 1.8 min. The level of sensitivity observed in our study brings us closer to that theoretically required for the detection of action currents in nerves. Copyright (c) 2006 Wiley-Liss, Inc.
Azizi, Shahrzad; Kheirandish, Reza; Rahimi, Elham
2014-11-12
Leptospirosis is a worldwide zoonotic disease that is caused by Gram-negative spirochaetes, Leptospira species. Affected animals excrete the organism in the urine into the environment and act as a source of infection. Cattle are maintenance hosts for some serovars of leptospirosis and are important in the transmission of the infection to humans. At post mortem examination, affected cattle show white spots in their kidneys but these are not specific for leptospirosis. Sometimes it is necessary that leptospirosis be diagnosed in the carcass. Different direct methods, including polymerase chain reaction (PCR), Warthin-Starry silver stain (WS), immunofluorescence (IF) and immunohistochemistry (IHC) can be used in order to diagnose leptospirosis in the affected tissues, such as kidney. The main advantage of the WS technique is direct visualisation of the bacteria in the tissue samples. Silver staining is useful for retrospective studies on formalin-fixed and paraffin-embedded samples but little information is available on the sensitivity and specificity of the technique. The present study aimed to find a simple and inexpensive method that can be used in any laboratory and that also, if clinical samples are not available, can detect Leptospira in tissue samples post mortem. This study was performed on 19 paraffin-embedded kidneys of slaughtered cows that grossly had focal to multifocal white spots. Leptospirosis was confirmed in these samples with PCR based on the LipL32 gene. Out of 19 PCR positive kidneys, Leptospira was identified in 13 stained samples by WS. The kidneys revealed different grades of interstitial nephritis. No relationship was found between severity of lesions and presence of leptospires in the kidneys. The PCR results on the urine and blood were consistent with matching WS stained kidneys. Out of 13 kidneys that were positive with silver staining, 7 matching blood and 10 matching urine samples were confirmed positive for leptospirosis with PCR. In this study, the WS technique provided fewer positive results than PCR. This may be as a result of a low burden of Leptospira in the kidney, but the sensitivity of WS staining needs more investigation.
Moewis, Philippe; Checa, Sara; Kutzner, Ines; Hommel, Hagen; Duda, Georg N
2018-01-01
Mechanical and kinematical aligning techniques are the usual positioning methods during total knee arthroplasty. However, alteration of the physiological joint line and unbalanced medio-lateral load distribution are considered disadvantages in the mechanical and kinematical techniques, respectively. The aim of this study was to analyse the influence of the joint line on the strain and stress distributions in an implanted knee and their sensitivity to rotational mal-alignment. Finite element calculations were conducted to analyse the stresses in the PE-Inlay and the mechanical strains at the bone side of the tibia component-tibia bone interface during normal positioning of the components and internal and external mal-rotation of the tibial component. Two designs were included, a horizontal and a physiological implant. The loading conditions are based on internal knee joint loads during walking. A medialization of the stresses on the PE-Inlay was observed in the physiological implant in a normal position, accompanied by higher stresses in the mal-rotated positions. Within the tibia component-tibia bone interface, similar strain distributions were observed in both implant geometries in the normal position. However, a medialization of the strains was observed in the physiological implant in both mal-rotated conditions with greater bone volume affected by higher strains. Although evident changes due to mal-rotation were observed, the stresses do not suggest a local plastic deformation of the PE-Inlay. The strains values within most of the tibia component-tibia bone interface were in the physiological strain zone and no significant bone changes would be expected. The physiological cut on the articular aspect showed no detrimental effect compared to the horizontal implant.
Denis, Julie; Forouzanfar, Faezeh; Herbrecht, Raoul; Toussaint, Elise; Kessler, Romain; Sabou, Marcela; Candolfi, Ermanno; Letsher-Bru, Valérie
2018-05-01
Invasive pulmonary aspergillosis (IPA) is a common complication of immunosuppression. Rapid diagnosis using molecular techniques is essential to improve patient survival. PCR techniques are promising in enhancing Aspergillus detection in blood and respiratory samples. We evaluate for the first time the performances of two commercial real-time PCR kits, the A. fumigatus Bio-Evolution and the MycoGENIE A. fumigatus for the detection of A. fumigatus DNA in bronchoalveolar lavage (BAL) from patients with and without IPA. Seventy-three BAL samples were included. Thirty-one of them corresponded to patients with probable IPA, 11 to patients with possible IPA, and 31 to patients without aspergillosis, according to the 2008 European Organization for Research and Treatment of Cancer/Mycoses Study Group criteria. In the probable IPA group, A. fumigatus Bio-Evolution and the MycoGENIE A. fumigatus real-time PCR kits showed a specificity of 100% and a sensitivity of 81% and 71%, respectively. The A. fumigatus Bio-Evolution detected Aspergillus DNA in the 14 BAL samples with a positive Aspergillus culture result, whereas the MycoGENIE A. fumigatus PCR result was positive only for 12. In the possible IPA group, there were no positive real-time PCR or positive Aspergillus culture results. For the patients without aspergillosis, no positive result was observed for real-time PCR kit, despite the presence of various other non-Aspergillus pathogens in this group. Our study demonstrates an excellent specificity and a good sensitivity of A. fumigatus DNA detection in BAL samples with both kits. Copyright © 2018 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Application of dermoscopy image analysis technique in diagnosing urethral condylomata acuminata.
Zhang, Yunjie; Jiang, Shuang; Lin, Hui; Guo, Xiaojuan; Zou, Xianbiao
2018-01-01
In this study, cases with suspected urethral condylomata acuminata were examined by dermoscopy, in order to explore an effective method for clinical. To study the application of dermoscopy image analysis technique in clinical diagnosis of urethral condylomata acuminata. A total of 220 suspected urethral condylomata acuminata were clinically diagnosed first with the naked eyes, and then by using dermoscopy image analysis technique. Afterwards, a comparative analysis was made for the two diagnostic methods. Among the 220 suspected urethral condylomata acuminata, there was a higher positive rate by dermoscopy examination than visual observation. Dermoscopy examination technique is still restricted by its inapplicability in deep urethral orifice and skin wrinkles, and concordance between different clinicians may also vary. Dermoscopy image analysis technique features a high sensitivity, quick and accurate diagnosis and is non-invasive, and we recommend its use.
Comparison of five diagnostic tests for Giardia duodenalis in fecal samples from young dogs.
Uehlinger, Fabienne D; Naqvi, S Ali; Greenwood, Spencer J; McClure, J Trenton; Conboy, Gary; O'Handley, Ryan; Barkema, Herman W
2017-09-15
Five diagnostic tests were compared for the diagnosis of Giardia duodenalis in fecal samples of young dogs. Fecal samples were collected from 136 healthy dogs <1year old and examined using immunofluorescence antibody microscopy (IFA) after sucrose gradient centrifugation, zinc sulfate centrifugal flotation technique (ZSCT), SNAP ® Giardia test, and ProSpecT ® Giardia EZ Microplate assay. In addition, polymerase chain reaction (PCR) of the 16S rRNA gene was performed. Kappa (κ) statistic was calculated to assess diagnostic agreement between the IFA and each test. Using the IFA as the gold standard, the relative sensitivity and specificity of each test were determined. Subsequently, a Bayesian approach was used to estimate the sensitivity and specificity of each test in comparison to the IFA results. Giardia duodenalis was detected in 41% of the samples examined by IFA. The ZSCT resulted in 37% of positive samples, with a relative sensitivity and specificity of 86 and 98%, respectively. The SNAP ® Giardia test was positive in 40% of the samples, with a relative sensitivity and specificity of 91 and 96%, respectively. The ProSpecT ® test was positive in 51% of the samples, with a relative sensitivity and specificity of 100 and 83%, respectively. The relative sensitivity and specificity for PCR were 58 and 56%, respectively, with 55% of samples being PCR-positive. While the sensitivity and specificity estimates of each test in comparison to the IFA changed when using a Bayesian approach, the conclusions remained the same. While the ProSpecT ® test was the most sensitive test in this study, it is not designed for dogs and more costly than the other tests. The SNAP ® Giardia test performed similar to the ZSCT but may be more favorable because it is fast and easy to perform. Performance of the PCR was poor and the benefit of PCR may be in determining genotypes for evaluating zoonotic transfer between dogs and humans. Copyright © 2017 Elsevier B.V. All rights reserved.
Iftikhar, Irim; Irfan, Seema; Farooqi, Joveria; Azizullah, Zahida; Hasan, Rumina
2017-01-01
With the rise in multidrug-resistant tuberculosis, there is a search for newer techniques that will rapidly detect drug-resistant Mycobacterium tuberculosis. Although molecular techniques can detect resistance, culture is still considered gold standard, especially in resource-limited settings where quick, cheap, and easy techniques are needed. The aim of the study was to evaluate microcolony method thin layer agar (TLA) for quick detection of resistance against the first- and second-line antituberculous drugs in clinical isolates. This was a cross-sectional study performed at Aga Khan University Hospital. A total of 87 Z-N stain smear-positive pulmonary samples were received and indirect drug susceptibility test (ID-DST) was performed using Lowenstein-Jensen and mycobacteria growth indicator tube. Direct DST was performed using TLA on 7H10 agar. TLA was observed twice weekly under microscope for 4 weeks. Sensitivity, specificity, and accuracy were calculated for TLA using indirect susceptibility method as the gold standard. Level of agreement was calculated using Kappa score. TLA showed sensitivity of 89% and 95.2% for isoniazid and rifampicin, while for ethionamide, ofloxacin, and injectable aminoglycosides, it was 96.6%, 92.1%, and 100%, respectively. Specificity for the first-line drugs was >95% while second-line drugs ranged from 70% to 100%. Mean time to positivity was 10.2 days by TLA as compared to 43.1 days by ID-DST. TLA is a quick and reliable method in identifying resistance, especially in resource-limited settings. However, additional liquid culture can be set up as backup, especially in patients on therapy to avoid false negative results.
A PCR method based on 18S rRNA gene for detection of malaria parasite in Balochistan.
Shahwani, Zubeda; Aleem, Abdul; Ahmed, Nazeer; Mushtaq, Muhammad; Afridi, Sarwat
2016-12-01
To establish a polymerase chain reaction method based on 18S ribosomal ribonucleic acid gene for the detection of plasmodium deoxyribonucleic acid in patients suffering from malaria symptoms. This cross-sectional study was conducted from September 2013 to October 2014 in district Quetta of Pakistan's Balochistan province. Blood samples were collected from patients suffering from general symptoms of malaria. A polymerase chain reaction-based technique was applied for the diagnosis of malaria and detection of responsible species in the patients who were suspected to carry the parasite. Performance of this polymerase chain reaction method was compared against the microscopy results. Parasite number was also calculated for microscopy positive samples.All samples after the genomic deoxyribonucleic acid isolation were subjected to polymerase chain reaction amplification and agarose gel electrophoresis. Of the 200 samples, 114(57%) were confirmed as positive and 86(43%) as negative for malaria by microscopy. Polymerase chain reaction identified 124(62%) samples as positive and 76(38%) as negative for malaria. The comparative analysis of both diagnostic methods confirmed 109(54.5%) samples as positive by both techniques. Besides, 5(6.58%) samples were identified as false positive and 15(12.1%) samples as false negative by polymerase chain reaction. Sensitivity, specificity and positive predictive values for polymerase chain reaction in comparison to microscopy were 87.98%, 93.42% and 96%, respectively. Polymerase chain reaction-based methods in malaria diagnosis and species identification were found to be more effective than other techniques.
Bountris, Panagiotis; Haritou, Maria; Pouliakis, Abraham; Margari, Niki; Kyrgiou, Maria; Spathis, Aris; Pappas, Asimakis; Panayiotides, Ioannis; Paraskevaidis, Evangelos A; Karakitsos, Petros; Koutsouris, Dimitrios-Dionyssios
2014-01-01
Nowadays, there are molecular biology techniques providing information related to cervical cancer and its cause: the human Papillomavirus (HPV), including DNA microarrays identifying HPV subtypes, mRNA techniques such as nucleic acid based amplification or flow cytometry identifying E6/E7 oncogenes, and immunocytochemistry techniques such as overexpression of p16. Each one of these techniques has its own performance, limitations and advantages, thus a combinatorial approach via computational intelligence methods could exploit the benefits of each method and produce more accurate results. In this article we propose a clinical decision support system (CDSS), composed by artificial neural networks, intelligently combining the results of classic and ancillary techniques for diagnostic accuracy improvement. We evaluated this method on 740 cases with complete series of cytological assessment, molecular tests, and colposcopy examination. The CDSS demonstrated high sensitivity (89.4%), high specificity (97.1%), high positive predictive value (89.4%), and high negative predictive value (97.1%), for detecting cervical intraepithelial neoplasia grade 2 or worse (CIN2+). In comparison to the tests involved in this study and their combinations, the CDSS produced the most balanced results in terms of sensitivity, specificity, PPV, and NPV. The proposed system may reduce the referral rate for colposcopy and guide personalised management and therapeutic interventions.
Bountris, Panagiotis; Haritou, Maria; Pouliakis, Abraham; Margari, Niki; Kyrgiou, Maria; Spathis, Aris; Pappas, Asimakis; Panayiotides, Ioannis; Paraskevaidis, Evangelos A.; Karakitsos, Petros; Koutsouris, Dimitrios-Dionyssios
2014-01-01
Nowadays, there are molecular biology techniques providing information related to cervical cancer and its cause: the human Papillomavirus (HPV), including DNA microarrays identifying HPV subtypes, mRNA techniques such as nucleic acid based amplification or flow cytometry identifying E6/E7 oncogenes, and immunocytochemistry techniques such as overexpression of p16. Each one of these techniques has its own performance, limitations and advantages, thus a combinatorial approach via computational intelligence methods could exploit the benefits of each method and produce more accurate results. In this article we propose a clinical decision support system (CDSS), composed by artificial neural networks, intelligently combining the results of classic and ancillary techniques for diagnostic accuracy improvement. We evaluated this method on 740 cases with complete series of cytological assessment, molecular tests, and colposcopy examination. The CDSS demonstrated high sensitivity (89.4%), high specificity (97.1%), high positive predictive value (89.4%), and high negative predictive value (97.1%), for detecting cervical intraepithelial neoplasia grade 2 or worse (CIN2+). In comparison to the tests involved in this study and their combinations, the CDSS produced the most balanced results in terms of sensitivity, specificity, PPV, and NPV. The proposed system may reduce the referral rate for colposcopy and guide personalised management and therapeutic interventions. PMID:24812614
Monitoring Neural Activity with Bioluminescence during Natural Behavior
Naumann, Eva A.; Kampff, Adam R.; Prober, David A.; Schier, Alexander F.; Engert, Florian
2010-01-01
Existing techniques for monitoring neural activity in awake, freely behaving vertebrates are invasive and difficult to target to genetically identified neurons. Here we describe the use of bioluminescence to non-invasively monitor the activity of genetically specified neurons in freely behaving zebrafish. Transgenic fish expressing the Ca2+-sensitive photoprotein GFP-apoAequorin (GA) in most neurons generated large and fast bioluminescent signals related to neural activity, neuroluminescence, that could be recorded continuously for many days. To test the limits of this technique, GA was specifically targeted to the hypocretin-positive neurons of the hypothalamus. We found that neuroluminescence generated by this group of ~20 neurons was associated with periods of increased locomotor activity and identified two classes of neural activity corresponding to distinct swim latencies. Thus, our neuroluminescence assay can report, with high temporal resolution and sensitivity, the activity of small subsets of neurons during unrestrained behavior. PMID:20305645
Global DNA methylation analysis using methyl-sensitive amplification polymorphism (MSAP).
Yaish, Mahmoud W; Peng, Mingsheng; Rothstein, Steven J
2014-01-01
DNA methylation is a crucial epigenetic process which helps control gene transcription activity in eukaryotes. Information regarding the methylation status of a regulatory sequence of a particular gene provides important knowledge of this transcriptional control. DNA methylation can be detected using several methods, including sodium bisulfite sequencing and restriction digestion using methylation-sensitive endonucleases. Methyl-Sensitive Amplification Polymorphism (MSAP) is a technique used to study the global DNA methylation status of an organism and hence to distinguish between two individuals based on the DNA methylation status determined by the differential digestion pattern. Therefore, this technique is a useful method for DNA methylation mapping and positional cloning of differentially methylated genes. In this technique, genomic DNA is first digested with a methylation-sensitive restriction enzyme such as HpaII, and then the DNA fragments are ligated to adaptors in order to facilitate their amplification. Digestion using a methylation-insensitive isoschizomer of HpaII, MspI is used in a parallel digestion reaction as a loading control in the experiment. Subsequently, these fragments are selectively amplified by fluorescently labeled primers. PCR products from different individuals are compared, and once an interesting polymorphic locus is recognized, the desired DNA fragment can be isolated from a denaturing polyacrylamide gel, sequenced and identified based on DNA sequence similarity to other sequences available in the database. We will use analysis of met1, ddm1, and atmbd9 mutants and wild-type plants treated with a cytidine analogue, 5-azaC, or zebularine to demonstrate how to assess the genetic modulation of DNA methylation in Arabidopsis. It should be noted that despite the fact that MSAP is a reliable technique used to fish for polymorphic methylated loci, its power is limited to the restriction recognition sites of the enzymes used in the genomic DNA digestion.
Kim, Sung-Jae; Chun, Yong-Min; Kim, Sung-Hwan; Moon, Hong-Kyo; Jang, Jae-Won
2013-07-01
The purpose of this study was to compare four graft-tunnel angles (GTA), the femoral GTA formed by three different femoral tunneling techniques (the outside-in, a modified inside-out technique in the posterior sag position with knee hyperflexion, and the conventional inside-out technique) and the tibia GTA in 3-dimensional (3D) knee flexion models, as well as to examine the influence of femoral tunneling techniques on the contact pressure between the intra-articular aperture of the femoral tunnel and the graft. Twelve cadaveric knees were tested. Computed tomography scans were performed at different knee flexion angles (0°, 45°, 90°, and 120°). Femoral and tibial GTAs were measured at different knee flexion angles on the 3D knee models. Using pressure sensitive films, stress on the graft of the angulation of the femoral tunnel aperture was measured in posterior cruciate ligament reconstructed cadaveric knees. Between 45° and 120° of knee flexion, there were no significant differences between the outside-in and modified inside-out techniques. However, the femoral GTA for the conventional inside-out technique was significantly less than that for the other two techniques (p<0.001). In cadaveric experiments using pressure-sensitive film, the maximum contact pressure for the modified inside-out and outside-in technique was significantly lower than that for the conventional inside-out technique (p=0.024 and p=0.017). The conventional inside-out technique results in a significantly lesser GTA and higher stress at the intra-articular aperture of the femoral tunnel than the outside-in technique. However, the results for the modified inside-out technique are similar to those for the outside-in technique.
Fu, Sha; Wang, Fang; Shao, Qiong; Zhang, Xu; Duan, Li-Ping; Zhang, Xiao; Zhang, Li; Shao, Jian-Yong
2015-04-01
Anaplastic lymphoma kinase (ALK) rearrangement is present in approximately 5% of lung adenocarcinoma. Clinical trials on ALK inhibitor phase I to III have shown an interesting disease control rate and acceptable tolerability in ALK rearrangement patients. In clinical application, the precise diagnostic strategy for identifying ALK rearrangements remains to be determined. In this study, ALK rearrangement was screened by using quantitative real-time reverse transcriptase polymerase chain reaction (qRT-PCR), direct sequencing, 2 fluorescence in situ hybridization (FISH) assays, and immunohistochemistry in 173 lung adenocarcinomas. We identified 18 cases (10.4%) with EML4-ALK fusion-positive by qRT-PCR, and all were positive for EML4-ALK fusion gene validated by direct sequencing. The result was consistent with that of other methods. Furthermore, of the 18 EML4-ALK fusion-positive cases, 16 (9.2%) were positive by using EML4-ALK fusion probe FISH, and 15 (8.7%) were positive by using ALK break-apart probe FISH and immunohistochemistry staining. Of the 18 ALK fusion-positive lung adenocarcinomas, 8 cases (44.4%) were histologically diagnosed as subtypes of cribriform adenocarcinoma, 7 cases (38.9%) as cribriform adenocarcinoma mixed with papillary and/or mucinous pattern, 2 cases (11.1%) as papillary adenocarcinoma, and 1 case (5.6%) as mucinous adenocarcinoma. In the present study, the ALK rearrangement frequency detected by qRT-PCR in Chinese NSCLC patients was higher than that in the western populations. QRT-PCR is a rapid, sensitive technology that could be used as a screening tool for identifying EML4-ALK fusion-positive NSCLC patients who would be sensitive for receiving ALK inhibitor therapy.
A Microseismometer for Terrestrial and Extraterrestrial Applications
NASA Technical Reports Server (NTRS)
Banerdt, W.; Kaiser, W.; Vanzandt, T.
1993-01-01
The scientific and technical requirements of extraterrestrial seismology place severe demands on instrumentation. Performance in terms of sensitivity, stability, and frequency band must match that of the best terrestrial instruments, at a fraction of the size, mass, and power. In addition, this performance must be realized without operator intervention in harsh temperature, shock, and radiation environments. These constraints have forced us to examine some fundamental limits of accelerometer design in order to produce a small, rugged, sensitive seismometer. Silicon micromachined sensor technology offers techniques for the fabrication of monolithic, robust, compact, low-power and -mass accelerometers. However, currently available sensors offer inadequate sensitivity and bandwidth. Our implementation of an advanced silicon micro machined seismometer is based on principles developed at JPL for high-sensitivity position sensor technology. The use of silicon micro machining technology with these new principles should enable the fabrication of a 10(exp -11) g sensitivity seismometer with a bandwidth of at least 0.01 to 20 Hz. The low Q properties of pure single-crystal silicon are essential in order to minimize the Brownian thermal noise limitations generally characteristic of seismometers with small proof masses. A seismometer consists of a spring-supported proof mass and a transducer for measuring its motion. For long period motion a position sensor is generally used, for which the displacement is proportional to the ground acceleration. The mechanical sensitivity can be increased either by increasing the proof mass or decreasing the spring stiffness, neither of which is desirable for planetary applications. Our approach has been to use an ultra sensitive capacitive position sensor with a sensitivity of better than 10(exp -13) m/Hz(exp 1/2). This allows the use of a stiffer suspension and a smaller proof mass. We have built several prototypes using these principles, and tests show that these devices can exhibit performance comparable to state-of-the-art instruments.
Theurer, M E; White, B J; Larson, R L; Schroeder, T C
2015-03-01
Bovine respiratory disease is an economically important syndrome in the beef industry, and diagnostic accuracy is important for optimal disease management. The objective of this study was to determine whether improving diagnostic sensitivity or specificity was of greater economic value at varied levels of respiratory disease prevalence by using Monte Carlo simulation. Existing literature was used to populate model distributions of published sensitivity, specificity, and performance (ADG, carcass weight, yield grade, quality grade, and mortality risk) differences among calves based on clinical respiratory disease status. Data from multiple cattle feeding operations were used to generate true ranges of respiratory disease prevalence and associated mortality. Input variables were combined into a single model that calculated estimated net returns for animals by diagnostic category (true positive, false positive, false negative, and true negative) based on the prevalence, sensitivity, and specificity for each iteration. Net returns for each diagnostic category were multiplied by the proportion of animals in each diagnostic category to determine group profitability. Apparent prevalence was categorized into low (<15%) and high (≥15%) groups. For both apparent prevalence categories, increasing specificity created more rapid, positive change in net returns than increasing sensitivity. Improvement of diagnostic specificity, perhaps through a confirmatory test interpreted in series or pen-level diagnostics, can increase diagnostic value more than improving sensitivity. Mortality risk was the primary driver for net returns. The results from this study are important for determining future research priorities to analyze diagnostic techniques for bovine respiratory disease and provide a novel way for modeling diagnostic tests.
Machine Learning to Differentiate Between Positive and Negative Emotions Using Pupil Diameter
Babiker, Areej; Faye, Ibrahima; Prehn, Kristin; Malik, Aamir
2015-01-01
Pupil diameter (PD) has been suggested as a reliable parameter for identifying an individual’s emotional state. In this paper, we introduce a learning machine technique to detect and differentiate between positive and negative emotions. We presented 30 participants with positive and negative sound stimuli and recorded pupillary responses. The results showed a significant increase in pupil dilation during the processing of negative and positive sound stimuli with greater increase for negative stimuli. We also found a more sustained dilation for negative compared to positive stimuli at the end of the trial, which was utilized to differentiate between positive and negative emotions using a machine learning approach which gave an accuracy of 96.5% with sensitivity of 97.93% and specificity of 98%. The obtained results were validated using another dataset designed for a different study and which was recorded while 30 participants processed word pairs with positive and negative emotions. PMID:26733912
NASA Astrophysics Data System (ADS)
Rothard, H.; Moshammer, R.; Ullrich, J.; Kollmus, H.; Mann, R.; Hagmann, S.; Zouros, T. J. M.
2007-05-01
First results on swift heavy ion induced electron emission from solids obtained with a reaction microscope are presented. This advanced technique, which is successfully used since quite some time to study electron ejection in ion-atom collisions, combines the measurement of the time-of-flight of electrons with imaging techniques. A combination of electric and magnetic fields guides the ejected electrons onto a position sensitive detector, which is capable to accept multiple hits. From position and time-of-flight measurement the full differential emission characteristics of up to 10 electrons per single incoming ion can be extracted. As a first example, we show energy spectra, angular distributions and the multiplicity distribution of electrons from impact of Au24+ (11 MeV/u) on a thin carbon foil (28 μg/cm2).
Sareen, Rateesh; Pandey, C L
2016-01-01
Background: Early diagnosis of lung cancer plays a pivotal role in reducing lung cancer death rate. Cytological techniques are safer, economical and provide quick results. Bronchoscopic washing, brushing and fine needle aspirations not only complement tissue biopsies in the diagnosis of lung cancer but also comparable. Objectives: (1) To find out diagnostic yields of bronchioalveolar lavage, bronchial brushings, FNAC in diagnosis of lung malignancy. (2) To compare relative accuracy of these three cytological techniques. (3) To correlate the cytologic diagnosis with clinical, bronchoscopic and CT findings. (4) Cytological and histopathological correlation of lung lesions. Methods: All the patients who came with clinical or radiological suspicion of lung malignancy in two and a half year period were included in study. Bronchoalveolar lavage was the most common type of cytological specimen (82.36%), followed by CT guided FNAC (9.45%) and bronchial brushings (8.19%). Sensitivity, specificity, positive and negative predictive value for all techniques and correlation with histopathology was done using standard formulas. Results: The most sensitive technique was CT FNAC – (87.25%) followed by brushings (77.78%) and BAL (72.69%). CT FNAC had highest diagnostic yield (90.38%), followed by brushings (86.67%) and BAL (83.67%). Specificity and positive predictive value were 100 % each of all techniques. Lowest false negatives were obtained in CT FNAC (12.5%) and highest in BAL (27.3%). Highest negative predictive value was of BAL 76.95 % followed by BB 75.59% and CT FNAC 70.59%. Conclusion: Before administering antitubercular treatment every effort should be made to rule out malignancy. CT FNAC had highest diagnostic yield among three cytological techniques. BAL is an important tool in screening central as well as in accessible lesions. It can be used at places where CT guided FNAC is not available or could not be done due to technical or financial limitations PMID:27890992
Advanced x-ray imaging spectrometer
NASA Technical Reports Server (NTRS)
Callas, John L. (Inventor); Soli, George A. (Inventor)
1998-01-01
An x-ray spectrometer that also provides images of an x-ray source. Coded aperture imaging techniques are used to provide high resolution images. Imaging position-sensitive x-ray sensors with good energy resolution are utilized to provide excellent spectroscopic performance. The system produces high resolution spectral images of the x-ray source which can be viewed in any one of a number of specific energy bands.
Fan, Wenpei; Shen, Bo; Bu, Wenbo; Zheng, Xiangpeng; He, Qianjun; Cui, Zhaowen; Ni, Dalong; Zhao, Kuaile; Zhang, Shengjian; Shi, Jianlin
2015-11-01
Biophotonic technology that uses light and ionizing radiation for positioned cancer therapy is a holy grail in the field of biomedicine because it can overcome the systemic toxicity and adverse side effects of conventional chemotherapy. However, the existing biophotonic techniques fail to achieve the satisfactory treatment efficacy, which remains a big challenge for clinical implementation. Herein, we develop a novel theranostic technique of "intranuclear biophotonics" by the smart design of a nuclear-targeting biophotonic system based on photo-/radio-sensitizers covalently co-loaded upconversion nanoparticles. These nuclear-targeting biophotonic agents can not only generate a great deal of multiple cytotoxic reactive oxygen species in the nucleus by making full use of NIR/X-ray irradiation, but also produce greatly enhanced intranuclear synergetic radio-/photodynamic therapeutic effects under the magnetic/luminescent bimodal imaging guidance, which may achieve the optimal efficacy in treating radio-resistant tumors. We anticipate that the highly effective intranuclear biophotonics will contribute significantly to the development of biophotonic techniques and open new perspectives for a variety of cancer theranostic applications. Copyright © 2015 Elsevier Ltd. All rights reserved.
Chirathaworn, Chintana; Janwitthayanan, Weena; Sereemaspun, Amornpun; Lertpocasombat, Kanchalee; Rungpanich, Utane; Ekpo, Pattama; Suwancharoen, Duangjai
2014-04-01
Detection of antibody specific to Leptospira by various immunological techniques has been used for leptospirosis diagnosis. However, the sensitivity of antibody detection during the first few days after infection is low. Molecular techniques are suggested to provide earlier diagnosis than antibody detection, but a rapid and easy to perform assay for Leptospira antigen detection would provide an additional useful tool for disease diagnosis. In this study, we coupled gold nanoparticles with antibody to LipL32, a protein commonly found in pathogenic Leptospira. This coupled gold reagent was used in the immunochromatographic strip for Leptospira detection. We demonstrated that the sensitivity of Leptospira detection by this strip was 10(3) ml(-1). There was no positive result detected when strips were tested with non-pathogenic Leptospira, Staphylococcus aureus, Streptococcus group B, Acinetobacter baumannii, Escherichia coli, Salmonella typhi, Klebsiella pneumoniae, Enterococcus faecalis or Enterococcus faecium. These data suggest that gold nanoparticles coupled with antibody to LipL32 could be used for Leptospira detection by a rapid test based on an immunochromatographic technique.
Fourier transform ion cyclotron resonance mass spectrometry
NASA Astrophysics Data System (ADS)
Marshall, Alan G.
1998-06-01
As for Fourier transform infrared (FT-IR) interferometry and nuclear magnetic resonance (NMR) spectroscopy, the introduction of pulsed Fourier transform techniques revolutionized ion cyclotron resonance mass spectrometry: increased speed (factor of 10,000), increased sensitivity (factor of 100), increased mass resolution (factor of 10,000-an improvement not shared by the introduction of FT techniques to IR or NMR spectroscopy), increased mass range (factor of 500), and automated operation. FT-ICR mass spectrometry is the most versatile technique for unscrambling and quantifying ion-molecule reaction kinetics and equilibria in the absence of solvent (i.e., the gas phase). In addition, FT-ICR MS has the following analytically important features: speed (~1 second per spectrum); ultrahigh mass resolution and ultrahigh mass accuracy for analysis of mixtures and polymers; attomole sensitivity; MSn with one spectrometer, including two-dimensional FT/FT-ICR/MS; positive and/or negative ions; multiple ion sources (especially MALDI and electrospray); biomolecular molecular weight and sequencing; LC/MS; and single-molecule detection up to 108 Dalton. Here, some basic features and recent developments of FT-ICR mass spectrometry are reviewed, with applications ranging from crude oil to molecular biology.
Ovine echinococcosis I. Immunological diagnosis by enzyme immunoassay.
Gatti, Antonio; Alvarez, Angela Rosa; Araya, Daniel; Mancini, Sergio; Herrero, Eduardo; Santillan, Graciela; Larrieu, Edmundo
2007-01-31
Immunodiagnosis in sheep presents problems of sensitivity and specificity, limiting its applicability in surveillance systems. The objective of this study was to develop a sensitive, specific and accessible technique for diagnosing cystic echinococcosis in naturally infected sheep and to evaluate the validity of necropsy as a reference test. A total of 247 sheep were studied at slaughterhouses, confirming the parasitological diagnosis with histology. Serum was processed with enzyme immunoassay (EIA) using three antigen preparations: total hydatid liquid (LHT), purified fraction of LHT (S2B) and purified lipoprotein (B). Western Blot (WB) was used as a control. EIA proved effective for differentiating Echinococcus granulosus from larval stage of Taenia hydatigena and intestinal cestodes in all three antigen preparations. Serums from macroscopically negative sheep were reactive to EIA and positive with WB. In the whole flock, sensitivity was 89.2% for LHT, 80.0% for S2B and 86.4% for B. Sensitivity in lambs was 78.6% for LHT, 75.0% for S2B and 64.3% for B. Macroscopic diagnosis at the time of slaughter was found to have limitations as a reference test for immunodiagnosis of cystic equinococcosis in sheep, so it was necessary to include histology and WB as reference tests. LHT was the antigen preparation of greatest value and EIA proved to be a sensitive and specific technique, adequate for surveillance systems and for evaluating control programmes.
Application of Timepix3 based CdTe spectral sensitive photon counting detector for PET imaging
NASA Astrophysics Data System (ADS)
Turecek, Daniel; Jakubek, Jan; Trojanova, Eliska; Sefc, Ludek; Kolarova, Vera
2018-07-01
Positron emission tomography (PET) is a nuclear medicine functional imaging technique. It is used in clinical oncology (medical imaging of tumors and the search for metastases), and pre-clinical studies using animals. PET uses small amounts of radioactive materials (radiotracers) and a special photon sensitive camera. Most of these cameras use scintillators with photomultipliers as detectors. However, these detectors have limited energy sensitivity and large pixels. Therefore, the false signal caused by a scattering poses a significant problem. In this work we study properties of position, energy and time sensitive semiconductor detector of Timepix3 type and its applicability for PET measurements. This work presents an initial study and evaluation of two Timepix3 detectors with 2 mm thick CdTe sensors used in simplified geometry for PET imaging. The study is performed on 2 samples - a capillary tube and a cylindrical plexiglass phantom with cavities. Both samples are filled with fluodeoxyglucose (FDG) solution that is used as a radiotracer. The Timepix3 offers better properties compared to conventional detectors - high granularity (55 μm pixel pitch), good energy resolution (1 keV at 60 keV) and sufficient time resolution (1.6 ns). The spectral sensitivity of Timepix3 together with coincidence/anticoincidence technique allows for significant reduction of background signal caused by Compton scattering and internal X-ray fluorescence of Cd and Te.
Minimum change in spherical aberration that can be perceived
Manzanera, Silvestre; Artal, Pablo
2016-01-01
It is important to know the visual sensitivity to optical blur from both a basic science perspective and a practical point of view. Of particular interest is the sensitivity to blur induced by spherical aberration because it is being used to increase depth of focus as a component of a presbyopic solution. Using a flicker detection-based procedure implemented on an adaptive optics visual simulator, we measured the spherical aberration thresholds that produce just-noticeable differences in perceived image quality. The thresholds were measured for positive and negative values of spherical aberration, for best focus and + 0.5 D and + 1.0 D of defocus. At best focus, the SA thresholds were 0.20 ± 0.01 µm and −0.17 ± 0.03 µm for positive and negative spherical aberration respectively (referred to a 6-mm pupil). These experimental values may be useful in setting spherical aberration permissible levels in different ophthalmic techniques. PMID:27699113
NASA Astrophysics Data System (ADS)
Granja, Carlos; Kraus, Vaclav; Pugatch, Valery; Kohout, Zdenek
2017-06-01
In low-energy nuclear reactions of astrophysical interest or fusion studies the spatial- and time-correlated detection of two and more reaction products can be a valuable tool in studies of reaction mechanisms, resolving reaction channels and measuring angular distributions of reaction products. For this purpose we constructed a configurable array of position-sensitive detectors based on the hybrid semiconductor pixel detector Timepix. Additional analog-signal electronics provide self-trigger together with extended multi-device control and synchronized readout electronics by a customized control and coincidence unit. The instrumentation, developed and used for detection of fission fragments in spontaneous and neutron induced fission as well as in charged particle detection in neutron induced reactions, is being implemented for low-energy light-ion induced nuclear reactions. Application and demonstration of the technique with two Timepix detectors on p+p elastic scattering at the Van-de-Graaff (VdG) accelerator in Prague is given.
Ofori-Anyinam, Boatema; Kanuteh, Fatoumatta; Agbla, Schadrac C; Adetifa, Ifedayo; Okoi, Catherine; Dolganov, Gregory; Schoolnik, Gary; Secka, Ousman; Antonio, Martin; de Jong, Bouke C; Gehre, Florian
2016-07-01
MPT64 rapid speciation tests are increasingly being used in diagnosis of tuberculosis (TB). Mycobacterium africanum West Africa 2 (Maf 2) remains an important cause of TB in West Africa and causes one third of disease in The Gambia. Since the introduction of MPT64 antigen tests, a higher than expected rate of suspected non-tuberculous mycobacteria (NTM) was seen among AFB smear positive TB suspects, which led us to prospectively assess sensitivity of the MPT64 antigen test in our setting. We compared the abundance of mRNA encoded by the mpt64 gene in sputa of patients with untreated pulmonary TB caused by Maf 2 and Mycobacterium tuberculosis (Mtb). Subsequently, prospectively collected sputum samples from presumptive TB patients were inoculated in the BACTEC MGIT 960 System. One hundred and seventy-three acid fast bacilli (AFB)-positive and blood agar negative MGIT cultures were included in the study. Cultures were tested on the day of MGIT positivity with the BD MGIT TBc Identification Test. A random set of positives and all negatives were additionally tested with the SD Bioline Ag MPT64 Rapid. MPT64 negative cultures were further incubated at 37°C and retested until positive. Bacteria were spoligotyped and assigned to different lineages. Maf 2 isolates were 2.52-fold less likely to produce a positive test result and sensitivity ranged from 78.4% to 84.3% at the beginning and end of the recommended 10 day testing window, respectively. There was no significant difference between the tests. We further showed that the decreased rapid test sensitivity was attributable to variations in mycobacterial growth behavior and the smear grades of the patient. In areas where Maf 2 is endemic MPT64 tests should be cautiously used and MPT64 negative results confirmed by a second technique, such as nucleic acid amplification tests, to avoid their misclassification as NTMs.
Mekonnen, Solomon A; Beissner, Marcus; Saar, Malkin; Ali, Solomon; Zeynudin, Ahmed; Tesfaye, Kassahun; Adbaru, Mulatu G; Battke, Florian; Poppert, Sven; Hoelscher, Michael; Löscher, Thomas; Bretzel, Gisela; Herbinger, Karl-Heinz
2017-10-02
Onchocerciasis is a parasitic disease caused by the filarial nematode Onchocerca volvulus. In endemic areas, the diagnosis is commonly confirmed by microscopic examination of skin snip samples, though this technique is considered to have low sensitivity. The available melting-curve based quantitative real-time PCR (qPCR) using degenerated primers targeting the O-150 repeat of O. volvulus was considered insufficient for confirming the individual diagnosis, especially in elimination studies. This study aimed to improve detection of O. volvulus DNA in clinical samples through the development of a highly sensitive qPCR assay. A novel hydrolysis probe based qPCR assay was designed targeting the specific sequence of the O. volvulus O-5S rRNA gene. A total of 200 clinically suspected onchocerciasis cases were included from Goma district in South-west Ethiopia, from October 2012 through May 2013. Skin snip samples were collected and subjected to microscopy, O-150 qPCR, and the novel O-5S qPCR. Among the 200 individuals, 133 patients tested positive (positivity rate of 66.5%) and 67 negative by O-5S qPCR, 74 tested positive by microscopy (37.0%) and 78 tested positive by O-150 qPCR (39.0%). Among the 133 O-5S qPCR positive individuals, microscopy and O-150 qPCR detected 55.6 and 59.4% patients, respectively, implying a higher sensitivity of O-5S qPCR than microscopy and O-150 qPCR. None of the 67 individuals who tested negative by O-5S qPCR tested positive by microscopy or O-150 qPCR, implying 100% specificity of the newly designed O-5S qPCR assay. The novel O-5S qPCR assay is more sensitive than both microscopic examination and the existing O-150 qPCR for the detection of O. volvulus from skin snip samples. The newly designed assay is an important step towards appropriate individual diagnosis and control of onchocerciasis.
Cloning-Independent and Counterselectable Markerless Mutagenesis System in Streptococcus mutans▿
Xie, Zhoujie; Okinaga, Toshinori; Qi, Fengxia; Zhang, Zhijun; Merritt, Justin
2011-01-01
Insertion duplication mutagenesis and allelic replacement mutagenesis are among the most commonly utilized approaches for targeted mutagenesis in bacteria. However, both techniques are limited by a variety of factors that can complicate mutant phenotypic studies. To circumvent these limitations, multiple markerless mutagenesis techniques have been developed that utilize either temperature-sensitive plasmids or counterselectable suicide vectors containing both positive- and negative-selection markers. For many species, these techniques are not especially useful due to difficulties of cloning with Escherichia coli and/or a lack of functional negative-selection markers. In this study, we describe the development of a novel approach for the creation of markerless mutations. This system employs a cloning-independent methodology and should be easily adaptable to a wide array of Gram-positive and Gram-negative bacterial species. The entire process of creating both the counterselection cassette and mutation constructs can be completed using overlapping PCR protocols, which allows extremely quick assembly and eliminates the requirement for either temperature-sensitive replicons or suicide vectors. As a proof of principle, we used Streptococcus mutans reference strain UA159 to create markerless in-frame deletions of 3 separate bacteriocin genes as well as triple mutants containing all 3 deletions. Using a panel of 5 separate wild-type S. mutans strains, we further demonstrated that the procedure is nearly 100% efficient at generating clones with the desired markerless mutation, which is a considerable improvement in yield compared to existing approaches. PMID:21948849
Acter, Thamina; Kim, Donghwi; Ahmed, Arif; Jin, Jang Mi; Yim, Un Hyuk; Shim, Won Joon; Kim, Young Hwan; Kim, Sunghwan
2016-05-01
This paper presents a detailed investigation of the feasibility of optimized positive and negative atmospheric pressure chemical ionization (APCI) mass spectrometry (MS) and atmospheric pressure photoionization (APPI) MS coupled to hydrogen-deuterium exchange (HDX) for structural assignment of diverse oxygen-containing compounds. The important parameters for optimization of HDX MS were characterized. The optimized techniques employed in the positive and negative modes showed satisfactory HDX product ions for the model compounds when dichloromethane and toluene were employed as a co-solvent in APCI- and APPI-HDX, respectively. The evaluation of the mass spectra obtained from 38 oxygen-containing compounds demonstrated that the extent of the HDX of the ions was structure-dependent. The combination of information provided by different ionization techniques could be used for better speciation of oxygen-containing compounds. For example, (+) APPI-HDX is sensitive to compounds with alcohol, ketone, or aldehyde substituents, while (-) APPI-HDX is sensitive to compounds with carboxylic functional groups. In addition, the compounds with alcohol can be distinguished from other compounds by the presence of exchanged peaks. The combined information was applied to study chemical compositions of degraded oils. The HDX pattern, double bond equivalent (DBE) distribution, and previously reported oxidation products were combined to predict structures of the compounds produced from oxidation of oil. Overall, this study shows that APCI- and APPI-HDX MS are useful experimental techniques that can be applied for the structural analysis of oxygen-containing compounds.
Fàbregas, N; Ewig, S; Torres, A; El-Ebiary, M; Ramirez, J; de La Bellacasa, J P; Bauer, T; Cabello, H
1999-10-01
A study was undertaken to assess the diagnostic value of different clinical criteria and the impact of microbiological testing on the accuracy of clinical diagnosis of suspected ventilator associated pneumonia (VAP). Twenty five deceased mechanically ventilated patients were studied prospectively. Immediately after death, multiple bilateral lung biopsy specimens (16 specimens/patient) were obtained for histological examination and quantitative lung cultures. The presence of both histological pneumonia and positive lung cultures was used as a reference test. The presence of infiltrates on the chest radiograph and two of three clinical criteria (leucocytosis, purulent secretions, fever) had a sensitivity of 69% and a specificity of 75%; the corresponding numbers for the clinical pulmonary infection score (CPIS) were 77% and 42%. Non-invasive as well as invasive sampling techniques had comparable values. The combination of all techniques achieved a sensitivity of 85% and a specificity of 50%, and these values remained virtually unchanged despite the presence of previous treatment with antibiotics. When microbiological results were added to clinical criteria, adequate diagnoses originating from microbiological results which might have corrected false positive and false negative clinical judgements (n = 5) were countered by a similar proportion of inadequate diagnoses (n = 6). Clinical criteria had reasonable diagnostic values. CPIS was not superior to conventional clinical criteria. Non-invasive and invasive sampling techniques had diagnostic values comparable to clinical criteria. An algorithm guiding antibiotic treatment exclusively by microbiological results does not increase the overall diagnostic accuracy and carries the risk of undertreatment.
Detection of CIN by naked eye visualization after application of acetic acid.
Londhe, M; George, S S; Seshadri, L
1997-06-01
A prospective study was undertaken to determine the sensitivity and specificity of acetic application to the cervix followed by naked eye visualization as a screening test for detection of cervical intraepithelial neoplasia. Three hundred and seventy two sexually active woman in the reproductive age group were studied. All the women underwent Papanicolaou test, acetic acid test and colposcopy. One hundred and seventy five woman were acetic acid test negative, 197 women were acetic acid test positive. The sensitivity of acetic acid test was 72.4%, specificity 54% and false negative rate 15.2%, as compared to papanicolaou test which had a sensitivity of 13.2%, specificity of 96.3% and false negative rate of 24.4%. The advantage of the acetic acid test lies in its easy technique, low cost and high sensitivity which are important factors for determining the efficacy of any screening programme in developing countries.
Gurol, Yesim; Akan, Hulya; Izbirak, Guldal; Tekkanat, Zuhal Tazegun; Gunduz, Tehlile Silem; Hayran, Osman; Yilmaz, Gulden
2010-06-01
It is aimed to detect the sensitivity and specificity of rapid antigen detection of group A beta hemolytic streptococci from throat specimen compared with throat culture. The other goal of the study is to help in giving clinical decisions in upper respiratory tract infections according to the age group, by detection of sensitivity and positive predictive values of the rapid tests and throat cultures. Rapid antigen detection and throat culture results for group A beta hemolytic streptococci from outpatients attending to our university hospital between the first of November 2005 and 31st of December 2008 were evaluated retrospectively. Throat samples were obtained by swabs from the throat and transported in the Stuart medium and Quickvue Strep A [Quidel, San Diego, USA] cassette test was applied and for culture, specimen was inoculated on 5% blood sheep agar and identified according to bacitracin and trimethoprim-sulphametaxazole susceptibility from beta hemolytic colonies. During the dates between the first of November 2005 and 31st of December 2008, from 453 patients both rapid antigen detection and throat culture were evaluated. Rapid antigen detection sensitivity and specificity were found to be 64.6% and 96.79%, respectively. The positive predictive value was 80.95% whereas negative predictive value was 92.82%. Kappa index was 0.91. When the results were evaluated according to the age groups, the sensitivity and the positive predictive value of rapid antigen detection in children were 70%, 90.3% and in adults 59.4%, 70.4%. When bacterial infection is concerned to prevent unnecessary antibiotic use, rapid streptococcal antigen test (RSAT) is a reliable method to begin immediate treatment. To get the maximum sensitivity of RSAT, the specimen collection technique used and education of the health care workers is important. While giving clinical decision, it must be taken into consideration that the sensitivity and the positive predictive value of the RSAT is quite lower in adult age group than in pediatric age group. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alves, Vinicius M.; Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599; Muratov, Eugene
Repetitive exposure to a chemical agent can induce an immune reaction in inherently susceptible individuals that leads to skin sensitization. Although many chemicals have been reported as skin sensitizers, there have been very few rigorously validated QSAR models with defined applicability domains (AD) that were developed using a large group of chemically diverse compounds. In this study, we have aimed to compile, curate, and integrate the largest publicly available dataset related to chemically-induced skin sensitization, use this data to generate rigorously validated and QSAR models for skin sensitization, and employ these models as a virtual screening tool for identifying putativemore » sensitizers among environmental chemicals. We followed best practices for model building and validation implemented with our predictive QSAR workflow using Random Forest modeling technique in combination with SiRMS and Dragon descriptors. The Correct Classification Rate (CCR) for QSAR models discriminating sensitizers from non-sensitizers was 71–88% when evaluated on several external validation sets, within a broad AD, with positive (for sensitizers) and negative (for non-sensitizers) predicted rates of 85% and 79% respectively. When compared to the skin sensitization module included in the OECD QSAR Toolbox as well as to the skin sensitization model in publicly available VEGA software, our models showed a significantly higher prediction accuracy for the same sets of external compounds as evaluated by Positive Predicted Rate, Negative Predicted Rate, and CCR. These models were applied to identify putative chemical hazards in the Scorecard database of possible skin or sense organ toxicants as primary candidates for experimental validation. - Highlights: • It was compiled the largest publicly-available skin sensitization dataset. • Predictive QSAR models were developed for skin sensitization. • Developed models have higher prediction accuracy than OECD QSAR Toolbox. • Putative chemical hazards in the Scorecard database were found using our models.« less
Thermal neutron detector based on COTS CMOS imagers and a conversion layer containing Gadolinium
NASA Astrophysics Data System (ADS)
Pérez, Martín; Blostein, Juan Jerónimo; Bessia, Fabricio Alcalde; Tartaglione, Aureliano; Sidelnik, Iván; Haro, Miguel Sofo; Suárez, Sergio; Gimenez, Melisa Lucía; Berisso, Mariano Gómez; Lipovetzky, Jose
2018-06-01
In this work we will introduce a novel low cost position sensitive thermal neutron detection technique, based on a Commercial Off The Shelf CMOS image sensor covered with a Gadolinium containing conversion layer. The feasibility of the neutron detection technique implemented in this work has been experimentally demonstrated. A thermal neutron detection efficiency of 11.3% has been experimentally obtained with a conversion layer of 11.6 μm. It was experimentally verified that the thermal neutron detection efficiency of this technique is independent on the intensity of the incident thermal neutron flux, which was confirmed for conversion layers of different thicknesses. Based on the experimental results, a spatial resolution better than 25 μm is expected. This spatial resolution makes the proposed technique specially useful for neutron beam characterization, neutron beam dosimetry, high resolution neutron imaging, and several neutron scattering techniques.
Studies of orbital Eoetvoes experiments
NASA Technical Reports Server (NTRS)
Chapman, P. K.
1977-01-01
A direct force-balance technique was analyzed for carrying out the Eoetvoes experiment in space, which is intended to give sufficient sensitivity to allow investigation of the gravitational interactions of energy stored in the weak interaction. The heart of experiment is an exceedingly sensitive dual accelerometer, containing two proof masses constructed of the materials whose Eoetvoes ratio is to be compared. For use in development of the accelerometer, a magnetic microbalance is proposed in which the weight of the proof mass is supported by magnetic forces which vary very slowly with the proof mass position. It is shown that at least two different mechanizations of the magnetic suspension may be feasible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lafleur, Adrienne M.; Ulrich, Timothy J. II; Menlove, Howard O.
Objective is to investigate the use of Passive Neutron Albedo Reactivity (PNAR) and Self-Interrogation Neutron Resonance Densitometry (SINRD) to quantify fissile content in FUGEN spent fuel assemblies (FAs). Methodology used is: (1) Detector was designed using fission chambers (FCs); (2) Optimized design via MCNPX simulations; and (3) Plan to build and field test instrument in FY13. Significance was to improve safeguards verification of spent fuel assemblies in water and increase sensitivity to partial defects. MCNPX simulations were performed to optimize the design of the SINRD+PNAR detector. PNAR ratio was less sensitive to FA positioning than SINRD and SINRD ratio wasmore » more sensitive to Pu fissile mass than PNAR. Significance was that the integration of these techniques can be used to improve verification of spent fuel assemblies in water.« less
Non-contact measurement of diamagnetic susceptibility change by a magnetic levitation technique
NASA Astrophysics Data System (ADS)
Takahashi, K.; Mogi, I.; Awaji, S.; Watanabe, K.
2011-03-01
A new method for measuring the temperature dependence of the diamagnetic susceptibility is described. It is based on the Faraday method and employs a magnetic levitation technique. The susceptibility of a magnetically levitating diamagnetic sample is determined from the product of the magnetic flux density and the field gradient at the levitating position observed using a micro CCD camera. The susceptibility of a sample during containerless melting and solidification can be measured to a precision of better than ±0.05%. The temperature dependence of the susceptibility of paraffin wax was measured by the magnetic levitation technique with an accuracy of ±0.25%. This method enables sensitive and contactless measurements of the diamagnetic susceptibility across the melting point with in situ observations.
Reducing false-positive detections by combining two stage-1 computer-aided mass detection algorithms
NASA Astrophysics Data System (ADS)
Bedard, Noah D.; Sampat, Mehul P.; Stokes, Patrick A.; Markey, Mia K.
2006-03-01
In this paper we present a strategy for reducing the number of false-positives in computer-aided mass detection. Our approach is to only mark "consensus" detections from among the suspicious sites identified by different "stage-1" detection algorithms. By "stage-1" we mean that each of the Computer-aided Detection (CADe) algorithms is designed to operate with high sensitivity, allowing for a large number of false positives. In this study, two mass detection methods were used: (1) Heath and Bowyer's algorithm based on the average fraction under the minimum filter (AFUM) and (2) a low-threshold bi-lateral subtraction algorithm. The two methods were applied separately to a set of images from the Digital Database for Screening Mammography (DDSM) to obtain paired sets of mass candidates. The consensus mass candidates for each image were identified by a logical "and" operation of the two CADe algorithms so as to eliminate regions of suspicion that were not independently identified by both techniques. It was shown that by combining the evidence from the AFUM filter method with that obtained from bi-lateral subtraction, the same sensitivity could be reached with fewer false-positives per image relative to using the AFUM filter alone.
Peeters, Bart; Herijgers, Paul; Beuselinck, Kurt; Peetermans, Willy E.; Herregods, Marie-Christin
2016-01-01
Identification of the causative pathogen of infective endocarditis (IE) is crucial for adequate management and therapy. A broad-range PCR-electrospray ionization mass spectrometry (PCR-ESI-MS) technique was compared with broad-spectrum 16S rRNA PCR and amplicon sequencing (16S rRNA PCR) for the detection of bacterial pathogens in 40 heart valves obtained from 34 definite infective endocarditis patients according to the modified Duke criteria and six nonendocarditis patients. Concordance between the two molecular techniques was 98% for being positive or negative, 97% for concordant identification up to the genus level, and 77% for concordant identification up to the species level. Sensitivity for detecting the causative pathogen (up to the genus level) in excised heart valves was 88% for 16S rRNA PCR and 85% for PCR-ESI-MS; the specificity was 83% for both methods. The two molecular techniques were significantly more sensitive than valve culture (18%) and accurately identified bacteria in excised heart valves. In eight patients with culture-negative IE, the following results were obtained: concordant detection of Coxiella burnetii (n = 2), Streptococcus gallolyticus (n = 1), Propionibacterium acnes (n = 1), and viridans group streptococci (n = 1) by both molecular tests, detection of P. acnes by PCR-ESI-MS whereas the 16S rRNA PCR was negative (n = 1), and a false-negative result by both molecular techniques (n = 2). In one case of IE caused by viridans streptococci, PCR-ESI-MS was positive for Enterococcus spp. The advantages of PCR-ESI-MS compared to 16S rRNA PCR are its automated workflow and shorter turnaround times. PMID:27629895
Khammari, Imen; Saghrouni, Fatma; Yaacoub, Alia; Gaied Meksi, Sondoss; Ach, Hinda; Garma, Lamia; Fathallah, Akila; Ben Saïd, Moncef
2013-08-01
The performance values of available techniques used in serodiagnosis of toxoplasmosis are satisfactory but they raise problems of equivocal and discordant results for very low IgG titers. Recently marketed, LDBio-Toxo II IgG Western blot (IB) showed an excellent correlation with the dye test. We estimated the proportion of equivocal and discordant results between the enzyme immunoassay Platelia Toxo IgG (EIA-IgG) and fluorescent antibody test (FAT) and assessed the usefulness of the IB as a confirmatory test. Out of 2,136 sera collected from pregnant women, 1,644 (77.0%) tested unequivocally positive and 407 (19.0%) were negative in both EIA-IgG and FAT. The remaining 85 (4%) sera showed equivocal or discordant results. Among them, 73 (85.9%) were positive and 12 (14.1%) were negative in IB. Forty-one (89.1%) equivocal sera in EIA-IgG and 46 (86.8%) equivocal sera in FAT were positive in IB. Reducing the cut-off values of both screening techniques improved significantly their sensitivity in detecting very low IgG titers at the expense of their specificity. In conclusion, equivocal results in routine-used techniques and their discordance in determination of the immune status in pregnancy women were not uncommon. IB test appeard to be highly useful in these situations as a confirmatory technique.
Calvani, Nichola Eliza Davies; Windsor, Peter Andrew; Bush, Russell David
2017-01-01
Background Fasciolosis, due to Fasciola hepatica and Fasciola gigantica, is a re-emerging zoonotic parasitic disease of worldwide importance. Human and animal infections are commonly diagnosed by the traditional sedimentation and faecal egg-counting technique. However, this technique is time-consuming and prone to sensitivity errors when a large number of samples must be processed or if the operator lacks sufficient experience. Additionally, diagnosis can only be made once the 12-week pre-patent period has passed. Recently, a commercially available coprological antigen ELISA has enabled detection of F. hepatica prior to the completion of the pre-patent period, providing earlier diagnosis and increased throughput, although species differentiation is not possible in areas of parasite sympatry. Real-time PCR offers the combined benefits of highly sensitive species differentiation for medium to large sample sizes. However, no molecular diagnostic workflow currently exists for the identification of Fasciola spp. in faecal samples. Methodology/Principal findings A new molecular diagnostic workflow for the highly-sensitive detection and quantification of Fasciola spp. in faecal samples was developed. The technique involves sedimenting and pelleting the samples prior to DNA isolation in order to concentrate the eggs, followed by disruption by bead-beating in a benchtop homogeniser to ensure access to DNA. Although both the new molecular workflow and the traditional sedimentation technique were sensitive and specific, the new molecular workflow enabled faster sample throughput in medium to large epidemiological studies, and provided the additional benefit of speciation. Further, good correlation (R2 = 0.74–0.76) was observed between the real-time PCR values and the faecal egg count (FEC) using the new molecular workflow for all herds and sampling periods. Finally, no effect of storage in 70% ethanol was detected on sedimentation and DNA isolation outcomes; enabling transport of samples from endemic to non-endemic countries without the requirement of a complete cold chain. The commercially-available ELISA displayed poorer sensitivity, even after adjustment of the positive threshold (65–88%), compared to the sensitivity (91–100%) of the new molecular diagnostic workflow. Conclusions/Significance Species-specific assays for sensitive detection of Fasciola spp. enable ante-mortem diagnosis in both human and animal settings. This includes Southeast Asia where there are potentially many undocumented human cases and where post-mortem examination of production animals can be difficult. The new molecular workflow provides a sensitive and quantitative diagnostic approach for the rapid testing of medium to large sample sizes, potentially superseding the traditional sedimentation and FEC technique and enabling surveillance programs in locations where animal and human health funding is limited. PMID:28915255
Akhtar, Mohammad Shabib; Mohsin, Nehal; Zahak, Ahmad; Ain, Mohammad Ruhal; Pillai, P K; Kapur, Prem; Ahmad, Mohammad Zaki
2014-01-01
Seventy-four bacterial proven cases of urinary tract infections were studied, and identified by Mac Conkey agar and blood agar medium separately; all the isolates were subjected to antimicrobial sensitivity testing by Stokes technique. Ninty-six percent of total isolated organisms were found to be gram negative while remaining 4% were gram positive. Among gram negatives, E. coli and gram positive S. aureus were the most prevalent organisms. The percentage of gram negative isolates were as follows, E. coli (79.7%) followed by Klebsiella (9.5%), Pseudomonas, Acinetobacter were (2.7% each), Proteus constituted (1.4%). and among gram positive S. aureus (4%). The antibiotic resistance of identified organisms was carried out by disc-diffusion method with commercially available disc of thirteen antibiotics having different mode of actions such as inhibition of cell wall synthesis, membrane permeability alternatives, inhibition of protein synthesis and DNA synthesis inhibitors. Gram negatives showed more resistance to these antibiotics as compared to gram positive organisms. The most effective antibiotic for gram negative UTI isolates is amikacin showing 63% efficacy followed by Cefotaxime 55% efficacy, Amoxicillin and Ciprofloxacin with (49% each) efficacy. Among gram positives, Chloramphenicol, Co-trimoxazole, Gentamicin, Amikacin, Ciprofloxacin and Cefotaxime are most effective with (66.6% each) efficacy, then Ampicillin, Amoxicillin, Tetracycline and norfloxacin with (33.3% each) efficacy.
Letovanec, Igor; Finn, Stephen; Zygoura, Panagiota; Smyth, Paul; Soltermann, Alex; Bubendorf, Lukas; Speel, Ernst-Jan; Marchetti, Antonio; Nonaka, Daisuke; Monkhorst, Kim; Hager, Henrik; Martorell, Miguel; Sejda, Aleksandra; Cheney, Richard; Hernandez-Losa, Javier; Verbeken, Eric; Weder, Walter; Savic, Spasenija; Di Lorito, Alessia; Navarro, Atilio; Felip, Enriqueta; Warth, Arne; Baas, Paul; Meldgaard, Peter; Blackhall, Fiona; Dingemans, Anne-Marie; Dienemann, Hendrik; Dziadziuszko, Rafal; Vansteenkiste, Johan; O'Brien, Cathal; Geiger, Thomas; Sherlock, Jon; Schageman, Jeoffrey; Dafni, Urania; Kammler, Roswitha; Kerr, Keith; Thunnissen, Erik; Stahel, Rolf; Peters, Solange
2018-03-01
The reported prevalence of ALK receptor tyrosine kinase gene (ALK) rearrangement in NSCLC ranges from 2% to 7%. The primary standard diagnostic method is fluorescence in situ hybridization (FISH). Recently, immunohistochemistry (IHC) has also proved to be a reproducible and sensitive technique. Reverse-transcriptase polymerase chain reaction (RT-PCR) has also been advocated, and most recently, the advent of targeted next-generation sequencing (NGS) for ALK and other fusions has become possible. This study compares anaplastic lymphoma kinase (ALK) evaluation with all four techniques in resected NSCLC from the large European Thoracic Oncology Platform Lungscape cohort. A total of 96 cases from the European Thoracic Oncology Platform Lungscape iBiobank, with any ALK immunoreactivity were examined by FISH, central RT-PCR, and NGS. An H-score higher than 120 defines IHC positivity. RNA was extracted from the same formalin-fixed, paraffin-embedded tissues. For RT-PCR, primers covered the most frequent ALK translocations. For NGS, the Oncomine Solid Tumour Fusion Transcript Kit (Thermo Fisher Scientific, Waltham, MA) was used. The concordance was assessed using the Cohen κ coefficient (two-sided α ≤ 5%). NGS provided results for 77 of the 95 cases tested (81.1%), whereas RT-PCR provided results for 77 of 96 (80.2%). Concordance occurred in 55 cases of the 60 cases tested with all four methods (43 ALK negative and 12 ALK positive). Using ALK copositivity for IHC and FISH as the criterion standard, we derived a sensitivity for RT-PCR/NGS of 70.0%/85.0%, with a specificity of 87.1%/79.0%. When either RT-PCR or NGS was combined with IHC, the sensitivity remained the same, whereas the specificity increased to 88.7% and 83.9% respectively. NGS evaluation with the Oncomine Solid Tumour Fusion transcript kit and RT-PCR proved to have high sensitivity and specificity, advocating their use in routine practice. For maximal sensitivity and specificity, ALK status should be assessed by using two techniques and a third one in discordant cases. We therefore propose a customizable testing algorithm. These findings significantly influence existing testing paradigms and have clear clinical and economic impact. Copyright © 2017 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.
Wang, Fei; He, Bei
2013-01-01
To investigate the role of endotracheal aspirate (EA) culture in the diagnosis and antibiotic management in ventilator-associated pneumonia (VAP). We searched CNKI, Wanfang, PUBMED and EMBASE databases published from January 1990 to December 2011, to find relevant literatures on VAP microbiological diagnostic techniques including EA and bronchoalveolar lavage (BALF). The following key words were used: ventilator associated pneumonia, diagnosis and adult. Meta-analysis was performed and the sensitivity and specificity of EA on VAP diagnosis were calculated. Our literature search identified 1665 potential articles, 8 of which fulfilled our selection criteria including 561 patients with paired cultures. Using BALF quantitative culture as reference standard, the sensitivity and specificity of EA were 72% and 71%. When considering quantitative culture of EA only, the sensitivity and specificity improved to 90% and 65%, while the positive and the negative predictive values were 68% and 89% respectively. However, the sensitivity and specificity of semi-quantitative culture of EA were only 50% and 80%, with a positive predictive value of 77% and a negative predictive value of 58% respectively. EA culture had relatively poor sensitivity and specificity, although quantitative culture of EA only could improve the sensitivity. Initiating therapy on the basis of EA quantitative culture may still result in excessive antibiotic usage. Our data suggested that EA could provide some information for clinical decision but could not replace the role of BALF quantitative culture in VAP diagnosis.
Rodríguez Cruz, Pedro M; Luo, Yue-Bei; Miller, James; Junckerstorff, Reimar C; Mastaglia, Frank L; Fabian, Victoria
2014-12-01
Although there have been several previous reports of immunohistochemical staining for MHC antigens in muscle biopsies, there appears to be a lack of consensus about its routine use in the diagnostic evaluation of biopsies from patients with suspected inflammatory myopathy. Positive MHC-I staining is nonspecific but is widely used as a marker for inflammatory myopathy, whilst the role of MHC-II staining is not clearly defined. We investigated the sensitivity and specificity of MHC-I and MHC-II immunostaining for the diagnosis of inflammatory myopathy in a large group of biopsies from a single reference laboratory. Positive staining for MHC-I was found to have a high sensitivity in biopsies from patients with inflammatory myopathy but a very low specificity, as it was also common in other non-inflammatory myopathies and neurogenic disorders. On the other hand, MHC-II positivity had a much higher specificity in all major subgroups of inflammatory myopathy, especially inclusion body myositis. The findings indicate that the combination of MHC-I and MHC-II staining results in a higher degree of specificity for the diagnosis of inflammatory myopathy and that in biopsies with inflammation, positive MHC-II staining strongly supports the diagnosis of an immune-mediated myopathy. We recommend that immunohistochemical staining for both MHC-I and MHC-II should be included routinely in the diagnostic evaluation of muscle biopsies from patients with suspected inflammatory myopathy. However, as the sensitivity and interpretation of MHC staining may depend on the technique used, further studies are needed to compare procedures in different centres and develop standardised protocols. Copyright © 2014 Elsevier B.V. All rights reserved.
Tarafder, M R; Carabin, H; Joseph, L; Balolong, E; Olveda, R; McGarvey, S T
2010-03-15
The accuracy of the Kato-Katz technique in identifying individuals with soil-transmitted helminth (STH) infections is limited by day-to-day variation in helminth egg excretion, confusion with other parasites and the laboratory technicians' experience. We aimed to estimate the sensitivity and specificity of the Kato-Katz technique to detect infection with Ascaris lumbricoides, hookworm and Trichuris trichiura using a Bayesian approach in the absence of a 'gold standard'. Data were obtained from a longitudinal study conducted between January 2004 and December 2005 in Samar Province, the Philippines. Each participant provided between one and three stool samples over consecutive days. Stool samples were examined using the Kato-Katz technique and reported as positive or negative for STHs. In the presence of measurement error, the true status of each individual is considered as latent data. Using a Bayesian method, we calculated marginal posterior densities of sensitivity and specificity parameters from the product of the likelihood function of observed and latent data. A uniform prior distribution was used (beta distribution: alpha=1, beta=1). A total of 5624 individuals provided at least one stool sample. One, two and three stool samples were provided by 1582, 1893 and 2149 individuals, respectively. All STHs showed variation in test results from day to day. Sensitivity estimates of the Kato-Katz technique for one stool sample were 96.9% (95% Bayesian Credible Interval [BCI]: 96.1%, 97.6%), 65.2% (60.0%, 69.8%) and 91.4% (90.5%, 92.3%), for A. lumbricoides, hookworm and T. trichiura, respectively. Specificity estimates for one stool sample were 96.1% (95.5%, 96.7%), 93.8% (92.4%, 95.4%) and 94.4% (93.2%, 95.5%), for A. lumbricoides, hookworm and T. trichiura, respectively. Our results show that the Kato-Katz technique can perform with reasonable accuracy with one day's stool collection for A. lumbricoides and T. trichiura. Low sensitivity of the Kato-Katz for detection of hookworm infection may be related to rapid degeneration of delicate hookworm eggs with time. (c) 2009 Australian Society for Parasitology Inc. Published by Elsevier Ltd. All rights reserved.
Carta, Gaspare; Palermo, Patrizia; Pasquale, Chiara; Conte, Valeria; Pulcinella, Ruggero; Necozione, Stefano; Cofini, Vincenza; Patacchiola, Felice
2018-06-01
The aim of this study was to evaluate accuracy, tolerability and side effects of office hysteroscopic-guided chromoperturbations in infertile women without anaesthesia. Forty-nine infertile women underwent the procedure to evaluate tubal patency and the uterine cavity. Women with unilateral or bilateral tubal stenosis at hysteroscopy with chromoperturbation, and women with bilateral tubal patency who did not conceive during the period of six months, underwent laparoscopy with chromoperturbation. The results obtained from hysteroscopy and laparoscopy in the assessment of tubal patency were compared. Sensitivity, specificity, accuracy, positive-predictive value and negative-predictive value were used to describe diagnostic performance. Pain and tolerance were assessed during procedure using a visual analogue scale (VAS). Side effects or late complications and pregnancy rate were also recorded three and six months after the procedure. The specificity was 87.8% (95% CI: 73.80-95.90), sensitivity was 85.7% (95% CI 57.20-98.20), positive and negative predictive values were 70.6% (95% CI: 44.00-89) and 94.7% (95% CI: 82.30-99.40), respectively. Pregnancy rate (PR) within six months after performance of hysteroscopy with chromoperturbation was 27%. Office hysteroscopy-guided selective chromoperturbation in infertile patients is a valid technique to evaluate tubal patency and uterine cavity.
Secondary node analysis as an indicator for axillary lymphadenectomy in breast cancer patients.
Cremades, Manel; Torres, Mireia; Solà, Montse; Navinés, Jordi; Pascual, Icíar; Mariscal, Antonio; Caballero, Albert; Castellà, Eva; Luna, Miguel Ángel; Julián, Joan Francesc
2017-11-01
Currently, there is no agreement regarding if it would be necessary to perform an axillary lymph node dissection (ALND) in patients who have macrometastases in the sentinel lymph node (SLN). We studied the utility of the secondary node analysis (SN), defined as the following node after the SLN in an anatomical and lymphatic pathway, as a sign of malignant axillary involvement. An observational, retrospective and multicentre study was designed to assess the utility of the SN as a sign of axillary involvement. Among 2273 patients with breast cancer, a valid sample of 283 was obtained representing those who had the SN studied. Main endpoints of our study were: the SLN, the SN and the ALND histological pattern. Sensitivity, specificity and precision of the test were also calculated. SN test, in cases with positive SLN, has a sensitivity of 61.1%, a specificity of 78.7%, a positive predictive value of 45.8% and a negative predictive value of 87.3% with a precision of 74.7%. The study of the SN together with the technique of the SLN allows a more precise staging of the axillary involvement, in patients with breast cancer, than just the SLN technique. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Näsvall, P; Wikner, F; Gunnarsson, U; Rutegård, J; Strigård, K
2014-10-01
Since there are no reliable investigative tools for imaging parastomal hernia, new techniques are needed. The aim of this study was to assess the validity of intrastomal three-dimensional ultrasonography (3D) as an alternative to CT scanning for the assessment of stomal complaints. Twenty patients with stomal complaints, indicating surgery, were examined preoperatively with a CT scan in the supine position and 3D intrastomal ultrasonography in the supine and erect positions. Comparison with findings at surgery, considered to be the true state, was made. Both imaging methods, 3D ultrasonography and CT scanning, showed high sensitivity (ultrasound 15/18, CT scan 15/18) and specificity (ultrasound 2/2, CT scan 1/2) when judged by a dedicated radiologist. Corresponding values for interpretation of CT scans in routine clinical practice was for sensitivity 17/18 and for specificity 1/2. 3D ultrasonography has a high validity and is a promising alternative to CT scanning in the supine position to distinguish a bulge from a parastomal hernia.
Porte, Lorena; Varela, Carmen; Haecker, Thomas; Morales, Sara; Weitzel, Thomas
2016-05-13
Campylobacter is a leading cause of bacterial gastroenteritis, but sensitive diagnostic methods such as culture are expensive and often not available in resource limited settings. Therefore, direct staining techniques have been developed as a practical and economical alternative. We analyzed the impact of replacing Campylobacter staining with culture for routine stool examinations in a private hospital in Chile. From January to April 2014, a total of 750 consecutive stool samples were examined in parallel by Hucker stain and Campylobacter culture. Isolation rates of Campylobacter were determined and the performance of staining was evaluated against culture as the gold standard. Besides, isolation rates of Campylobacter and other enteric pathogens were compared to those of past years. Campylobacter was isolated by culture in 46 of 750 (6.1 %) stool samples. Direct staining only identified three samples as Campylobacter positive and reached sensitivity and specificity values of 6.5 and 100 %, respectively. In comparison to staining-based detection rates of previous years, we observed a significant increase of Campylobacter cases in our patients. Direct staining technique for Campylobacter had a very low sensitivity compared to culture. Staining methods might lead to a high rate of false negative results and an underestimation of the importance of campylobacteriosis. With the inclusion of Campylobacter culture, this pathogen became a leading cause of intestinal infection in our patient population.
Sutha, P; Jayanthi, V E
2017-12-08
Birth defect-related demise is mainly due to congenital heart defects. In the earlier stage of pregnancy, fetus problem can be identified by finding information about the fetus to avoid stillbirths. The gold standard used to monitor the health status of the fetus is by Cardiotachography(CTG), cannot be used for long durations and continuous monitoring. There is a need for continuous and long duration monitoring of fetal ECG signals to study the progressive health status of the fetus using portable devices. The non-invasive method of electrocardiogram recording is one of the best method used to diagnose fetal cardiac problem rather than the invasive methods.The monitoring of the fECG requires development of a miniaturized hardware and a efficient signal processing algorithms to extract the fECG embedded in the mother ECG. The paper discusses a prototype hardware developed to monitor and record the raw mother ECG signal containing the fECG and a signal processing algorithm to extract the fetal Electro Cardiogram signal. We have proposed two methods of signal processing, first is based on the Least Mean Square (LMS) Adaptive Noise Cancellation technique and the other method is based on the Wavelet Transformation technique. A prototype hardware was designed and developed to acquire the raw ECG signal containing the mother and fetal ECG and the signal processing techniques were used to eliminate the noises and extract the fetal ECG and the fetal Heart Rate Variability was studied. Both the methods were evaluated with the signal acquired from a fetal ECG simulator, from the Physionet database and that acquired from the subject. Both the methods are evaluated by finding heart rate and its variability, amplitude spectrum and mean value of extracted fetal ECG. Also the accuracy, sensitivity and positive predictive value are also determined for fetal QRS detection technique. In this paper adaptive filtering technique uses Sign-sign LMS algorithm and wavelet techniques with Daubechies wavelet, employed along with de noising techniques for the extraction of fetal Electrocardiogram.Both the methods are having good sensitivity and accuracy. In adaptive method the sensitivity is 96.83, accuracy 89.87, wavelet sensitivity is 95.97 and accuracy is 88.5. Additionally, time domain parameters from the plot of heart rate variability of mother and fetus are analyzed.
Hontoir, Fanny; Nisolle, Jean-François; Meurisse, Hubert; Simon, Vincent; Tallier, Max; Vanderstricht, Renaud; Antoine, Nadine; Piret, Joëlle; Clegg, Peter; Vandeweerd, Jean-Michel
2014-01-01
Articular cartilage defects are prevalent in metacarpo/metatarsophalangeal (MCP/MTP) joints of horses. The aim of this study was to determine and compare the sensitivity and specificity of 3-Tesla magnetic resonance imaging (3-T MRI) and computed tomography arthrography (CTA) to identify structural cartilage defects in the equine MCP/MTP joint. Forty distal cadaver limbs were imaged by CTA (after injection of contrast medium) and by 3-T MRI using specific sequences, namely, dual-echo in the steady-state (DESS), and sampling perfection with application-optimised contrast using different flip-angle evolutions (SPACE). Gross anatomy was used as the gold standard to evaluate sensitivity and specificity of both imaging techniques. CTA sensitivity and specificity were 0.82 and 0.96, respectively, and were significantly higher than those of MRI (0.41 and 0.93, respectively) in detecting overall cartilage defects (no defect vs. defect). The intra and inter-rater agreements were 0.96 and 0.92, respectively, and 0.82 and 0.88, respectively, for CT and MRI. The positive predictive value for MRI was low (0.57). CTA was considered a valuable tool for assessing cartilage defects in the MCP/MTP joint due to its short acquisition time, its specificity and sensitivity, and it was also more accurate than MRI. However, MRI permits assessment of soft tissues and subchondral bone and is a useful technique for joint evaluation, although clinicians should be aware of the limitations of this diagnostic technique, including reduced accuracy. Copyright © 2013 Elsevier Ltd. All rights reserved.
Automated detection of microcalcification clusters in mammograms
NASA Astrophysics Data System (ADS)
Karale, Vikrant A.; Mukhopadhyay, Sudipta; Singh, Tulika; Khandelwal, Niranjan; Sadhu, Anup
2017-03-01
Mammography is the most efficient modality for detection of breast cancer at early stage. Microcalcifications are tiny bright spots in mammograms and can often get missed by the radiologist during diagnosis. The presence of microcalcification clusters in mammograms can act as an early sign of breast cancer. This paper presents a completely automated computer-aided detection (CAD) system for detection of microcalcification clusters in mammograms. Unsharp masking is used as a preprocessing step which enhances the contrast between microcalcifications and the background. The preprocessed image is thresholded and various shape and intensity based features are extracted. Support vector machine (SVM) classifier is used to reduce the false positives while preserving the true microcalcification clusters. The proposed technique is applied on two different databases i.e DDSM and private database. The proposed technique shows good sensitivity with moderate false positives (FPs) per image on both databases.
NASA Astrophysics Data System (ADS)
Li, Chen; Yin, Xiaokang; Li, Zhen; Li, Wei; Chen, Guoming
2018-04-01
Capacitive imaging (CI) technique is a novel electromagnetic NDE technique. The Quasi-static electromagnetic field from the carefully designed electrode pair will vary when the electrical properties of the sample change, leading to the possibility of imaging. It is observed that for a given specimen, the targeted features appear as different variations in capacitive images under different experimental conditions. In some cases, even opposite variations occur, which brings confusion to indication interpretation. It is thus thought interesting to embark on investigations into the cause and effects of the negative variation phenomenon. In this work, the positive and negative variations were first explained from the measurement sensitivity distribution perspective. This was then followed by a detailed analysis using finite element models in COMSOL. A parametric experimental study on a glass fiber composite plate with artificial defects was then carried out to investigate how the experimental conditions affect the variation.
Reconsidering the Current Preterm Premature Rupture of Membranes Antibiotic Prophylactic Protocol.
Wolf, Maya Frank; Miron, Dan; Peleg, David; Rechnitzer, Hagai; Portnov, Igor; Salim, Raed; Keness, Yoram; Reich, Dan; Ami, Moshe Ben; Peretz, Avi; Koshnir, Amir; Shachar, Inbar Ben
2015-11-01
The purpose of our study was to determine whether the current antibiotic regimen for preterm premature rupture of membranes (PPROM) is adequate for covering the current causative agents and sensitivities of chorioamnionitis and early-onset neonatal sepsis. During a 3-year period, we retrieved the results from placental and amniotic membrane cultures obtained at delivery in cases of maternal fever, chorioamnionitis, and PPROM, and from blood cultures obtained from neonates with early-onset sepsis (EOS) in three participating hospitals. Sensitivity of pathogens to antimicrobial agents was performed using routine microbiologic techniques. There were 1,133 positive placental or amniotic cultures, 740 (65.3%) were from gram-negative Enterobacteriaceae. There were 27 neonates diagnosed with EOS with positive blood cultures. Aerobic Enterobacteriaceae accounted for 14 cases (52%) and group B streptococcus for 7 cases (26%). Of the Escherichia coli and Klebsiella sp., only 38% were sensitive to ampicillin. Local pathogens and their antibiotic sensitivity profiles should be explored every few years and an effective antibiotic protocol chosen to cover the main pathogens causing chorioamnionitis and EOS. Consideration should be made for changing ampicillin in women with PPROM to a regimen with better coverage of gram-negative Enterobacteriaceae. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Automatic brain tumor detection in MRI: methodology and statistical validation
NASA Astrophysics Data System (ADS)
Iftekharuddin, Khan M.; Islam, Mohammad A.; Shaik, Jahangheer; Parra, Carlos; Ogg, Robert
2005-04-01
Automated brain tumor segmentation and detection are immensely important in medical diagnostics because it provides information associated to anatomical structures as well as potential abnormal tissue necessary to delineate appropriate surgical planning. In this work, we propose a novel automated brain tumor segmentation technique based on multiresolution texture information that combines fractal Brownian motion (fBm) and wavelet multiresolution analysis. Our wavelet-fractal technique combines the excellent multiresolution localization property of wavelets to texture extraction of fractal. We prove the efficacy of our technique by successfully segmenting pediatric brain MR images (MRIs) from St. Jude Children"s Research Hospital. We use self-organizing map (SOM) as our clustering tool wherein we exploit both pixel intensity and multiresolution texture features to obtain segmented tumor. Our test results show that our technique successfully segments abnormal brain tissues in a set of T1 images. In the next step, we design a classifier using Feed-Forward (FF) neural network to statistically validate the presence of tumor in MRI using both the multiresolution texture and the pixel intensity features. We estimate the corresponding receiver operating curve (ROC) based on the findings of true positive fractions and false positive fractions estimated from our classifier at different threshold values. An ROC, which can be considered as a gold standard to prove the competence of a classifier, is obtained to ascertain the sensitivity and specificity of our classifier. We observe that at threshold 0.4 we achieve true positive value of 1.0 (100%) sacrificing only 0.16 (16%) false positive value for the set of 50 T1 MRI analyzed in this experiment.
[Immunodiagnostic methods in lupus erythematosus disseminatus].
Storch, H; Schwenke, H; Helbig, W
1975-12-01
In 27 patients with lupus erythematodes diseminatus the determinations of the LE-cells according to the macromethod (Zimmer and Hargraves) and the micromethod (Mudrik and co-workers) were compared with the demonstration of antinuclear factors according to the indirect immunofluorescence and immune enzyme technique. The sensitiveness of the two last-mentioned immunomorphological methods is somewhat larger. In these cases the size of the titre of the antinuclear factor almost always correlates positively with the number of the LE-cells. For the purpose of the initial diagnostics and the judgment of the course a morphological method cannot be renounced, since in the acute episode a high consumption of the antinuclear factor the immunological methods negatively correlate with the number of the LE-cells. The immune enzyme technique is to be recommended on account of the smaller expenditure, permanence of the preparations and high sensitiveness as alternative method of the immunofluorescence technique. In the micromethod the large variation is opposite to the advantage of the slight quantity of blood and to an always existing evaluability. Investigations of the lymphocytes of patients with lupus erythematodes disseminatus by means of the lymphocyte transformation test and the determination of the B-cells with the help of the direct immune peroxidase technique refer to the close pathogenetic connections of cellular and humoral immune reactions in this disease.
Whole-blood viscosity and the insulin-resistance syndrome.
Høieggen, A; Fossum, E; Moan, A; Enger, E; Kjeldsen, S E
1998-02-01
In a previous study we found that elevated blood viscosity was linked to the insulin resistance syndrome, and we proposed that high blood viscosity may increase insulin resistance. That study was based on calculated viscosity. To determine whether directly measured whole-blood viscosity was related to the insulin-resistance syndrome in the same way as calculated viscosity had been found to be. Healthy young men were examined with the hyperinsulinemic isoglycemic glucose clamp technique, and we related insulin sensitivity (glucose disposal rate) to other metabolic parameters and to blood viscosity. We established a technique for direct measurement of whole-blood viscosity. There were statistically significant negative correlations between glucose disposal rate and whole-blood viscosity at low and high shear rates (r = -0.41, P = 0.007 for both, n = 42). Whole-blood viscosity was correlated positively (n = 15) to serum triglyceride (r = 0.54, P = 0.04) and total cholesterol (r = 0.52, P = 0.05), and negatively with high-density lipoprotein cholesterol (r = -0.53, P = 0.04) concentrations. Insulin sensitivity index was correlated positively to high-density lipoprotein cholesterol (r = 0.54, P = 0.04) and negatively to serum triglyceride (r = -0.69, P = 0.005) and to total cholesterol (r = -0.81, P = 0.0003) concentrations. The present results demonstrate for the first time that there is a negative relationship between directly measured whole-blood viscosity and insulin sensitivity as a part of the insulin-resistance syndrome. Whole-blood viscosity contributes to the total peripheral resistance, and these results support the hypothesis that insulin resistance has a hemodynamic basis.
Thomassin-Naggara, I; Bendifallah, S; Rousset, P; Bazot, M; Ballester, M; Darai, E
2018-03-01
Diagnostic performance of MR imaging for the diagnosis of pelvic endometriosis are good. Even if some differences of performances exists according the location considered, the risk of misdiagnosis is lower than 10% for trained teams (NP2). The performance of pelvic MR imaging and surgery are quite similar to diagnose endometrioma (sensitivity and specificity>90%). A negative pelvic MR imaging allows to exclude deep pelvic endometriosis with a performance similar to surgery but a positive MR imaging is less accurate than surgery because of a high number of false positives (23%). Pelvic MR imaging is more sensitive and less specific than ultrasonography for the diagnosis of uterosacral ligament, vagina or recto vaginal septum (NP2). Pelvic ultrasonography is more sensitive than pelvic MR imaging for the diagnosis of colorectal location (NP3). Pelvic MR imaging is a reproducible technique for the diagnosis of pelvic endometriosis (NP3). Regarding, quality criteria of pelvic MR imaging, no data are enough to recommend a specific MR unit, digestive preparation, or a specific moment during the menstrual cycle to realize the examination. Vaginal and/or rectal opacification are options. Most of studies are based a protocol including 3D T2W and 3DT1W sequences. Gadolinium injection is useful to characterize a complex adnexal mass. In clinical routine, slices crossing the kidneys are useful to evaluate the presence of pyelo calic distension. ColoCT is an accurate technique to diagnose pelvic digestive endometriosis (rectosigmoide and iléocaecal) (NP3). Copyright © 2018 Elsevier Masson SAS. All rights reserved.
FEAST: sensitive local alignment with multiple rates of evolution.
Hudek, Alexander K; Brown, Daniel G
2011-01-01
We present a pairwise local aligner, FEAST, which uses two new techniques: a sensitive extension algorithm for identifying homologous subsequences, and a descriptive probabilistic alignment model. We also present a new procedure for training alignment parameters and apply it to the human and mouse genomes, producing a better parameter set for these sequences. Our extension algorithm identifies homologous subsequences by considering all evolutionary histories. It has higher maximum sensitivity than Viterbi extensions, and better balances specificity. We model alignments with several submodels, each with unique statistical properties, describing strongly similar and weakly similar regions of homologous DNA. Training parameters using two submodels produces superior alignments, even when we align with only the parameters from the weaker submodel. Our extension algorithm combined with our new parameter set achieves sensitivity 0.59 on synthetic tests. In contrast, LASTZ with default settings achieves sensitivity 0.35 with the same false positive rate. Using the weak submodel as parameters for LASTZ increases its sensitivity to 0.59 with high error. FEAST is available at http://monod.uwaterloo.ca/feast/.
Molla Kazemiha, Vahid; Bonakdar, Shahin; Amanzadeh, Amir; Azari, Shahram; Memarnejadian, Arash; Shahbazi, Shirin; Shokrgozar, Mohammad Ali; Mahdian, Reza
2016-08-01
Mycoplasmas are the most important contaminants of cell cultures throughout the world. They are considered as a major problem in biological studies and biopharmaceutical economic issues. In this study, our aim was to find the best standard technique as a rapid method with high sensitivity, specificity and accuracy for the detection of mycoplasma contamination in the cell lines of the National Cell Bank of Iran. Thirty cell lines suspected to mycoplasma contamination were evaluated by five different techniques including microbial culture, indirect DNA DAPI staining, enzymatic mycoalert(®) assay, conventional PCR and real-time PCR. Five mycoplasma-contaminated cell lines were assigned as positive controls and five mycoplasma-free cell lines as negative controls. The enzymatic method was performed using the mycoalert(®) mycoplasma detection kit. Real-time PCR technique was conducted by PromoKine diagnostic kits. In the conventional PCR method, mycoplasma genus-specific primers were designed to analyze the sequences based on a fixed and common region on 16S ribosomal RNA with PCR product size of 425 bp. Mycoplasma contamination was observed in 60, 56.66, 53.33, 46.66 and 33.33 % of 30 different cell cultures by real-time PCR, PCR, enzymatic mycoalert(®), indirect DNA DAPI staining and microbial culture methods, respectively. The analysis of the results of the different methods showed that the real-time PCR assay was superior the other methods with the sensitivity, specificity, accuracy, predictive value of positive and negative results of 100 %. These values were 94.44, 100, 96.77, 100 and 92.85 % for the conventional PCR method, respectively. Therefore, this study showed that real-time PCR and PCR assays based on the common sequences in the 16S ribosomal RNA are reliable methods with high sensitivity, specificity and accuracy for detection of mycoplasma contamination in cell cultures and other biological products.
Domingo, Cristina; Escadafal, Camille; Rumer, Leonid; Méndez, Jairo A.; García, Paquita; Sall, Amadou A.; Teichmann, Anette; Donoso-Mantke, Oliver; Niedrig, Matthias
2012-01-01
Objective We describe an external quality assurance (EQA) study designed to assess the efficiency and accurateness of molecular and serological methods used by expert laboratories performing YF diagnosis. Study Design For molecular diagnosis evaluation, a panel was prepared of 14 human plasma samples containing specific RNA of different YFV strains (YFV-17D, YFV South American strain [Brazil], YFV IvoryC1999 strain), and specificity samples containing other flaviviruses and negative controls. For the serological panel, 13 human plasma samples with anti-YFV-specific antibodies against different strains of YFV (YFV-17D strain, YFV IvoryC1999 strain, and YFV Brazilian strain), as well as specificity and negative controls, were included. Results Thirty-six laboratories from Europe, the Americas, Middle East, and Africa participated in these EQA activities. Only 16% of the analyses reported met all evaluation criteria with optimal performance. Serial dilutions of YFV-17D showed that in general the methodologies reported provided a suitable sensitivity. Failures were mainly due to the inability to detect wild-type strains or the presence of false positives. Performance in the serological diagnosis varied, mainly depending on the methodology used. Anti-YFV IgM detection was not performed in 16% of the reports using IIF or ELISA techniques, although it is preferable for the diagnosis of YFV acute infections. A good sensitivity profile was achieved in general; however, in the detection of IgM antibodies a lack of sensitivity of anti-YFV antibodies against the vaccine strain 17D was observed, and of the anti-YFV IgG antibodies against a West African strain. Neutralization assays showed a very good performance; however, the unexpected presence of false positives underlined the need of improving the running protocols. Conclusion This EQA provides information on each laboratory's efficacy of RT-PCR and serological YFV diagnosis techniques. The results indicate the need for improving serological and molecular diagnosis techniques and provide a follow-up of the diagnostic profiles. PMID:22570700
Domingo, Cristina; Escadafal, Camille; Rumer, Leonid; Méndez, Jairo A; García, Paquita; Sall, Amadou A; Teichmann, Anette; Donoso-Mantke, Oliver; Niedrig, Matthias
2012-01-01
We describe an external quality assurance (EQA) study designed to assess the efficiency and accurateness of molecular and serological methods used by expert laboratories performing YF diagnosis. For molecular diagnosis evaluation, a panel was prepared of 14 human plasma samples containing specific RNA of different YFV strains (YFV-17D, YFV South American strain [Brazil], YFV IvoryC1999 strain), and specificity samples containing other flaviviruses and negative controls. For the serological panel, 13 human plasma samples with anti-YFV-specific antibodies against different strains of YFV (YFV-17D strain, YFV IvoryC1999 strain, and YFV Brazilian strain), as well as specificity and negative controls, were included. Thirty-six laboratories from Europe, the Americas, Middle East, and Africa participated in these EQA activities. Only 16% of the analyses reported met all evaluation criteria with optimal performance. Serial dilutions of YFV-17D showed that in general the methodologies reported provided a suitable sensitivity. Failures were mainly due to the inability to detect wild-type strains or the presence of false positives. Performance in the serological diagnosis varied, mainly depending on the methodology used. Anti-YFV IgM detection was not performed in 16% of the reports using IIF or ELISA techniques, although it is preferable for the diagnosis of YFV acute infections. A good sensitivity profile was achieved in general; however, in the detection of IgM antibodies a lack of sensitivity of anti-YFV antibodies against the vaccine strain 17D was observed, and of the anti-YFV IgG antibodies against a West African strain. Neutralization assays showed a very good performance; however, the unexpected presence of false positives underlined the need of improving the running protocols. This EQA provides information on each laboratory's efficacy of RT-PCR and serological YFV diagnosis techniques. The results indicate the need for improving serological and molecular diagnosis techniques and provide a follow-up of the diagnostic profiles.
Bajaj, Ashish; Bhatia, Vinay; Dutt, Sarjana
2016-01-01
Introduction Tuberculosis remains one of the deadliest communicable diseases. There are number of tests available for the diagnosis of tuberculosis but conventional microscopy has low sensitivity and culture although gold standard, but takes longer time for positivity. On the other side, Nucleic acid amplification techniques due to its rapidity and sensitivity not only help in early diagnosis and management of tuberculosis especially in patients with high clinical suspicion like immunocompromised patients, history of contact with active tuberculosis patient etc., but also curtail the transmission of the disease. Aim To evaluate the sensitivity, specificity, positive predictive value and negative predictive value of Nucleic acid amplification assay (GeneXpert) using respiratory samples in patients with suspected pulmonary tuberculosis and compare with AFB smear microscopy (Ziehl Neelsen stain) and Acid Fast Bacilli (AFB) culture. Materials and Methods We retrospectively reviewed the respiratory samples of suspected pulmonary tuberculosis (including Bronchoalveolar lavage and sputum) of 170 patients from Jan 2015 to Nov 2015 for ZN stain, culture and GeneXpert (Xpert® MTB/Rif assay). The sensitivity, specificity, PPV and NPV of GeneXpert and ZN microscopy were calculated using Liquid culture of Mycobacterium tuberculosis as gold standard. Results A total of 170 patient samples were evaluated in final analysis. Of these, 14 samples were positive by all three methods used in our study. The overall sensitivity, specificity, PPV and NPV of GeneXpert were 86.8%, 93.1%, 78.5% and 96% respectively and for BAL sample, 81.4%, 93.4%, 73.3% and 95.7% respectively. The overall sensitivity and specificity of AFB smear microscopy were 22.2%, % and 78.5% respectively and for BAL sample 22.2% and 100% respectively. For AFB negative samples sensitivity and specificity were 79.1% and 93.1% respectively. Conclusion GeneXpert has a higher sensitivity than AFB smear microscopy in respiratory samples. GeneXpert can be a useful tool for early diagnosis of patients with high clinical suspicion of pulmonary tuberculosis. Positive GeneXpert, but culture negative results should be read cautiously and be well correlated with clinical and treatment history of the patient. The other major advantage of Gene Xpert is that it simultaneously detects Rifampicin resistance and especially beneficial in patient with MDR and HIV associated tuberculosis and should be studied further. PMID:27437212
Manipulation of biological samples using micro and nano techniques.
Castillo, Jaime; Dimaki, Maria; Svendsen, Winnie Edith
2009-01-01
The constant interest in handling, integrating and understanding biological systems of interest for the biomedical field, the pharmaceutical industry and the biomaterial researchers demand the use of techniques that allow the manipulation of biological samples causing minimal or no damage to their natural structure. Thanks to the advances in micro- and nanofabrication during the last decades several manipulation techniques offer us the possibility to image, characterize and manipulate biological material in a controlled way. Using these techniques the integration of biomaterials with remarkable properties with physical transducers has been possible, giving rise to new and highly sensitive biosensing devices. This article reviews the different techniques available to manipulate and integrate biological materials in a controlled manner either by sliding them along a surface (2-D manipulation), by grapping them and moving them to a new position (3-D manipulation), or by manipulating and relocating them applying external forces. The advantages and drawbacks are mentioned together with examples that reflect the state of the art of manipulation techniques for biological samples (171 references).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bouet, T.; Schmitt, M.; Desuzinges, C.
1990-11-01
Hyperemia associated with an inflammatory response has been investigated in rats, by using four different experimental models, i.e., positive and negative polymer implants from the pharmacopea, operative control, and abscess induced by turpentine oil. 133Xenon clearance, infrared thermography and Laser Doppler Flowmetry (LDF) were used to monitor the subcutaneous local hemodynamic changes from 1 to 40 postoperative days. LDF proved to be a sensitive, reproducible method, able to discriminate positive from negative implants already at the 3rd postoperative day and up to 40 days. This increased local blood flow was also visualized at the site of positive implants at themore » 14th and 21st postoperative days by means of 133Xe Clearance. Additional information obtained by infrared thermography allowed discrimination between positive implants and control sites but only at the very early stage (1 to 3 days). The significance of the different data collected by the three techniques was correlated with histological events occurring at the different implant sites. LDF may therefore represent a useful technique for noninvasive semiquantitative assessment of tissue response to biomaterials.« less
Recent Advancements in DNA Damage-Transcription Crosstalk and High-Resolution Mapping of DNA Breaks.
Vitelli, Valerio; Galbiati, Alessandro; Iannelli, Fabio; Pessina, Fabio; Sharma, Sheetal; d'Adda di Fagagna, Fabrizio
2017-08-31
Until recently, DNA damage arising from physiological DNA metabolism was considered a detrimental by-product for cells. However, an increasing amount of evidence has shown that DNA damage could have a positive role in transcription activation. In particular, DNA damage has been detected in transcriptional elements following different stimuli. These physiological DNA breaks are thought to be instrumental for the correct expression of genomic loci through different mechanisms. In this regard, although a plethora of methods are available to precisely map transcribed regions and transcription start sites, commonly used techniques for mapping DNA breaks lack sufficient resolution and sensitivity to draw a robust correlation between DNA damage generation and transcription. Recently, however, several methods have been developed to map DNA damage at single-nucleotide resolution, thus providing a new set of tools to correlate DNA damage and transcription. Here, we review how DNA damage can positively regulate transcription initiation, the current techniques for mapping DNA breaks at high resolution, and how these techniques can benefit future studies of DNA damage and transcription.
Ximenes, Camila; Brandão, Eduardo; Oliveira, Paula; Rocha, Abraham; Rego, Tamisa; Medeiros, Rafael; Aguiar-Santos, Ana; Ferraz, João; Reis, Christian; Araujo, Paulo; Carvalho, Luiz; Melo, Fabio L
2014-12-01
The Global Program for the Elimination of Lymphatic Filariasis (GPELF) aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR)-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2) and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2), which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.
NASA Astrophysics Data System (ADS)
Zoriniants, George; Masia, Francesco; Giannakopoulou, Naya; Langbein, Wolfgang; Borri, Paola
2017-10-01
Single nanoparticle tracking using optical microscopy is a powerful technique with many applications in biology, chemistry, and material sciences. Despite significant advances, localizing objects with nanometric position precision in a scattering environment remains challenging. Applied methods to achieve contrast are dominantly fluorescence based, with fundamental limits in the emitted photon fluxes arising from the excited-state lifetime as well as photobleaching. Here, we show a new four-wave-mixing interferometry technique, whereby the position of a single nonfluorescing gold nanoparticle of 25-nm radius is determined with 16 nm precision in plane and 3 nm axially from rapid single-point measurements at 1-ms acquisition time by exploiting optical vortices. The precision in plane is consistent with the photon shot-noise, while axially it is limited by the nano-positioning sample stage, with an estimated photon shot-noise limit of 0.5 nm. The detection is background-free even inside biological cells. The technique is also uniquely sensitive to particle asymmetries of only 0.5% ellipticity, corresponding to a single atomic layer of gold, as well as particle orientation. This method opens new ways of unraveling single-particle trafficking within complex 3D architectures.
Parodi, S; Pala, M; Russo, P; Balbi, C; Abelmoschi, M L; Taningher, M; Zunino, A; Ottaggio, L; de Ferrari, M; Carbone, A; Santi, L
1983-07-01
Nitrofurantoin was not positive as a carcinogen in long term assays. In vitro it was positive in some short term tests and negative in others. We have examined Nitrofurantoin for its capability of inducing DNA damage in vivo. With the alkaline elution technique, Nitrofurantoin appeared clearly positive in all the tissues examined (liver, kidney, lung, spleen and bone marrow). In the liver we also observed some cross-linking effect. In bone marrow cells Nitrofurantoin was also clearly positive in terms of sister chromatid exchanges (SCEs) induction. DNA damage in vivo was also examined with a viscosimetric method, more sensitive than alkaline elution. With this method the results were essentially negative, suggesting that the two methods detect different types of damage. In view of its positivity in many organs and in two short term tests in vivo, the carcinogenic potential of Nitrofurantoin should be reconsidered.
Brook, Gary
2015-12-01
To identify point-of-care (POC) and rapid nucleic acid amplification techniques (NAATs) for the diagnosis of chlamydia and gonorrhoea and assess their utility. Literature search for available POC and rapid NAATs. The performance from the best-performing assays were applied hypothetically to patients in the clinic in which 100 consecutive patients with chlamydia and 100 with gonorrhoea were diagnosed in 1737 and 4575 patients respectively, with 44/100 and 54/100 treated at first attendance, respectively. 11 POC and 1 rapid NAAT were identified. Published performances for the best POC for chlamydia (CRT) were: sensitivity 41%-87%, specificity 89%-99.6%. Our data suggest that if this assay was used instead of our current NAAT, for every 100 patients diagnosed currently, 23-46 extra patients would be treated at first attendance; 10-35 would go undiagnosed with 7-191 false-positives. Best chlamydia rapid NAAT (GeneXpert): sensitivity 97.5%-98.7%, specificity 99.4%-99.9%. Anticipated performance for every 100 patients diagnosed currently: 0 extra patients treated at first attendance, 1-3 undiagnosed, 0-2 false-positives. Best POC for gonorrhoea (GC Check): sensitivity 54%-70%, specificity 97%-98%. Anticipated performance for every 100 patients diagnosed currently: 14-18 extra patients treated at first attendance, 28-32 undiagnosed, 92-137 false-positives. Best rapid NAAT for gonorrhoea (GeneXpert): sensitivity 96%-100%, specificity 99.9%-100%. Anticipated performance for every 100 patients diagnosed currently: 0 extra patients treated at first attendance, 0-4 undiagnosed, 0-5 false-positives. Rapid NAAT would reduce time to treatment by 4 days for initially untreated patients. POC assays would need to be used in conjunction with a NAAT, increasing early treatment rates expense and false-positive results. The rapid NAAT could be used alone, with a reduction in average time-to-treat and a small reduction in sensitivity and specificity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Bactericidal Effects of Charged Silver Nanoparticles in Methicillin-resistant Staphylococcus aureus
NASA Astrophysics Data System (ADS)
Romero-Urbina, Dulce; Velazquez-Salazar, J. Jesus; Lara, Humberto H.; Arellano-Jimenez, Josefina; Larios, Eduardo; Yuan, Tony T.; Hwang, Yoon; Desilva, Mauris N.; Jose-Yacaman, Miguel
2015-03-01
The increased number of infections due to antibiotic-resistant bacteria is a major concern to society. The objective of this work is to determine the effect of positively charged AgNPs on methicillin-sensitive Staphylococcus aureus (MSSA) and methicillin-resistant Staphylococcus aureus(MRSA) cell wall using advanced electron microscopy techniques. Positively charged AgNPs suspensions were synthesized via a microwave heating technique. The suspensions were then characterized by Dynamic Light Scattering (DLS) and Transmission Electron Microscopy (TEM) showing AgNPs size range from 5 to 30 nm. MSSA and MRSA were treated with positively charged AgNPs concentrations ranging from 0.06 mM to 31 mM. The MIC50 studies showed that viability of MSSA and MRSA could be reduced by 50% at a positively charged AgNPs concentration of 0.12 mM supported by Scanning-TEM (STEM) images demonstrating bacteria cell wall disruption leading to lysis after treatment with AgNPs. The results provide insights into one mechanism in which positively charged AgNPs are able to reduce the viability of MSSA and MRSA. This research is supported by National Institute on Minority Health and Health Disparities (G12MD007591) from NIH, NSF-PREM Grant No. DMR-0934218, The Welch Foundation and NAMRU-SA work number G1009.
A pilot study of myofascial release therapy compared to Swedish massage in Fibromyalgia
Liptan, Ginevra; Mist, Scott; Wright, Cheryl; Arzt, Anna; Jones, Kim Dupree
2017-01-01
Summary Fibromyalgia (FM) is characterized by widespread muscle pain and soft tissue tenderness. However, a lack of definitive muscle pathology has made FM both a diagnostic and a treatment puzzle. Much of the evidence for pathology in FM lies in the central nervous system – in particular abnormal amplification of pain signals in the spinal cord – a manifestation of central sensitization. An emerging body of evidence posits that peripheral pain generated from the muscles and fascia may trigger and maintain central sensitization in FM. Since FM patients so frequently seek manual therapy to relieve muscle symptoms, the present study compared two different manual therapy techniques in a parallel study of women with FM. Eight subjects received myofascial release (MFR) while four subjects received Swedish massage, 90 min weekly for four weeks. Overall symptom burden and physical function were assessed by the Fibromyalgia Impact Questionnaire Revised (FIQ-R). A unique challenge for the manual therapist in treating conditions involving central sensitization is to determine if localized pain reduction can be achieved with targeted therapy in the context of ongoing widespread pain. Localized pain improvement was measured by a novel questionnaire developed for this study, the modified Nordic Musculoskeletal Questionnaire (NMQ). Between-group differences in FIQ-R did not reach statistical significance, but the total change scores on FIQ-R for the MFR group (mean = 10.14, SD = 16.2) trended in the hypothesized and positive direction compared to the Swedish massage group (mean = 0.33, SD = 4.93) yielding a positive Aikin separation test. Although overall modified NMQ scores improved in both groups there were no consistent focal areas of improvement for the Swedish massage group. In contrast, the MFR group reported consistent pain reductions in the neck and upper back regions on the NMQ. These data support the need for larger randomized controlled trials of MFR versus other massage techniques and support the assessment of localized pain reduction in future manual therapy studies in FM. PMID:23768283
Azevedo, Michelle de Campos Soriani; Ramuno, Natália Mortari; Fachin, Luciana Raquel Vincenzi; Tassa, Mônica; Rosa, Patrícia Sammarco; Belone, Andrea de Faria Fernandes; Diório, Suzana Madeira; Soares, Cleverson Teixeira; Garlet, Gustavo Pompermaier; Trombone, Ana Paula Favaro
Leprosy, whose etiological agent is Mycobacterium leprae, is a chronic infectious disease that mainly affects the skin and peripheral nervous system. The diagnosis of leprosy is based on clinical evaluation, whereas histopathological analysis and bacilloscopy are complementary diagnostic tools. Quantitative PCR (qPCR), a current useful tool for diagnosis of infectious diseases, has been used to detect several pathogens including Mycobacterium leprae. The validation of this technique in a robust set of samples comprising the different clinical forms of leprosy is still necessary. Thus, in this study samples from 126 skin biopsies (collected from patients on all clinical forms and reactional states of leprosy) and 25 slit skin smear of leprosy patients were comparatively analyzed by qPCR (performed with primers for the RLEP region of M. leprae DNA) and routine bacilloscopy performed in histological sections or in slit skin smear. Considering clinical diagnostic as the gold standard, 84.9% of the leprosy patients were qPCR positive in skin biopsies, resulting in 84.92% sensitivity, with 84.92 and 61.22% positive (PPV) and negative (NPV) predictive values, respectively. Concerning bacilloscopy of histological sections (BI/H), the sensitivity was 80.15% and the PPV and NPV were 80.15 and 44.44%, respectively. The concordance between qPCR and BI/H was 87.30%. Regarding the slit skin smear, 84% of the samples tested positive in the qPCR. Additionally, qPCR showed 100% specificity, since all samples from different mycobacteria, from healthy individuals, and from other granulomatous diseases presented negative results. In conclusion, the qPCR technique for detection of M. leprae using RLEP primers proved to be specific and sensitive, and qPCR can be used as a complementary test to diagnose leprosy irrespective of the clinical form of disease. Copyright © 2016 Sociedade Brasileira de Infectologia. Published by Elsevier Editora Ltda. All rights reserved.
Arthroscopic Diagnosis of the Triangular Fibrocartilage Complex Foveal Tear: A Cadaver Assessment.
Trehan, Samir K; Wall, Lindley B; Calfee, Ryan P; Shen, Tony S; Dy, Christopher J; Yannascoli, Sarah M; Goldfarb, Charles A
2018-01-25
To determine whether the arthroscopic hook and trampoline tests are accurate and reliable diagnostic tests for foveal triangular fibrocartilage complex (TFCC) detachment. Wrist arthroscopy was performed on 10 cadaveric upper extremities. Arthroscopic hook and trampoline tests were performed and videos recorded (baseline). The deep foveal TFCC insertion was then sharply detached. Arthroscopic hook and trampoline tests were repeated. Subsequently, the foveal detachment was repaired via an ulnar tunnel technique and the hook test was repeated for a third time. Videos were independently reviewed at 2 time points by 2 fellowship-trained hand surgeons and 1 hand surgery fellow in a randomized and blinded fashion. Hook and trampoline tests were graded as positive or negative. Proportions of categorical variables were compared via 2-tailed Fisher exact test. Inter- and intraobserver reliabilities were assessed via Cohen kappa coefficient. The sensitivity and specificity of the hook test for foveal detachment diagnosis were 90% and 90%, respectively. There was 90% agreement among all 3 observers for the baseline and foveal detachment hook tests. Cohen kappa coefficients for the inter- and intraobserver reliabilities of the hook test were 0.87 and 0.81, respectively. Seventeen percent of trampoline tests were positive at baseline versus 43% after foveal detachment. The trampoline test had 45% agreement between the 3 observers. Cohen kappa coefficients for the inter- and intraobserver reliabilities of the trampoline test were 0.16 and 0.63, respectively. Following ulnar tunnel repair, 20% of hook tests were positive. The hook test is highly sensitive, specific, and reliable for the diagnosis of isolated TFCC foveal detachment. The trampoline test has insufficient reliability to assess foveal detachment. A TFCC foveal repair using an ulnar tunnel technique returns the hook test to baseline. The hook test is a sensitive, specific, and reliable test for the diagnosis of isolated TFCC foveal detachment. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Mapping of HLA- DQ haplotypes in a group of Danish patients with celiac disease.
Lund, Flemming; Hermansen, Mette N; Pedersen, Merete F; Hillig, Thore; Toft-Hansen, Henrik; Sölétormos, György
2015-10-01
A cost-effective identification of HLA- DQ risk haplotypes using the single nucleotide polymorphism (SNP) technique has recently been applied in the diagnosis of celiac disease (CD) in four European populations. The objective of the study was to map risk HLA- DQ haplotypes in a group of Danish CD patients using the SNP technique. Cohort A: Among 65 patients with gastrointestinal symptoms we compared the HLA- DQ2 and HLA- DQ8 risk haplotypes obtained by the SNP technique (method 1) with results based on a sequence specific primer amplification technique (method 2) and a technique used in an assay from BioDiagene (method 3). Cohort B: 128 patients with histologically verified CD were tested for CD risk haplotypes (method 1). Patients with negative results were further tested for sub-haplotypes of HLA- DQ2 (methods 2 and 3). Cohort A: The three applied methods provided the same HLA- DQ2 and HLA- DQ8 results among 61 patients. Four patients were negative for the HLA- DQ2 and HLA- DQ8 haplotypes (method 1) but were positive for the HLA- DQ2.5-trans and HLA- DQ2.2 haplotypes (methods 2 and 3). Cohort B: A total of 120 patients were positive for the HLA- DQ2.5-cis and HLA- DQ8 haplotypes (method 1). The remaining seven patients were positive for HLA- DQ2.5-trans or HLA- DQ2.2 haplotypes (methods 2 and 3). One patient was negative with all three HLA methods. The HLA- DQ risk haplotypes were detected in 93.8% of the CD patients using the SNP technique (method 1). The sensitivity increased to 99.2% by combining methods 1 - 3.
Zhou, Xuhui; Xu, Xia; Zhou, Guiyao; Luo, Yiqi
2018-02-01
Temperature sensitivity of soil organic carbon (SOC) decomposition is one of the major uncertainties in predicting climate-carbon (C) cycle feedback. Results from previous studies are highly contradictory with old soil C decomposition being more, similarly, or less sensitive to temperature than decomposition of young fractions. The contradictory results are partly from difficulties in distinguishing old from young SOC and their changes over time in the experiments with or without isotopic techniques. In this study, we have conducted a long-term field incubation experiment with deep soil collars (0-70 cm in depth, 10 cm in diameter of PVC tubes) for excluding root C input to examine apparent temperature sensitivity of SOC decomposition under ambient and warming treatments from 2002 to 2008. The data from the experiment were infused into a multi-pool soil C model to estimate intrinsic temperature sensitivity of SOC decomposition and C residence times of three SOC fractions (i.e., active, slow, and passive) using a data assimilation (DA) technique. As active SOC with the short C residence time was progressively depleted in the deep soil collars under both ambient and warming treatments, the residences times of the whole SOC became longer over time. Concomitantly, the estimated apparent and intrinsic temperature sensitivity of SOC decomposition also became gradually higher over time as more than 50% of active SOC was depleted. Thus, the temperature sensitivity of soil C decomposition in deep soil collars was positively correlated with the mean C residence times. However, the regression slope of the temperature sensitivity against the residence time was lower under the warming treatment than under ambient temperature, indicating that other processes also regulated temperature sensitivity of SOC decomposition. These results indicate that old SOC decomposition is more sensitive to temperature than young components, making the old C more vulnerable to future warmer climate. © 2017 John Wiley & Sons Ltd.
1989-04-01
subtraction readout (Klein 1967). This technique was used to investigate the early formation of periapical lesions prior to diagnosis by clinical...have investigated the diagnostic sensitivity of radiographs by determining the size, shape and position of bony lesions that can be visualized in...radiographs. Several studies using created defects in dried skulls have reported that interproximal lesions were not visible as long as the cortical plates
Doping in Two Elite Athletics Competitions Assessed by Randomized-Response Surveys.
Ulrich, Rolf; Pope, Harrison G; Cléret, Léa; Petróczi, Andrea; Nepusz, Tamás; Schaffer, Jay; Kanayama, Gen; Comstock, R Dawn; Simon, Perikles
2018-01-01
Doping in sports compromises fair play and endangers health. To deter doping among elite athletes, the World Anti-Doping Agency (WADA) oversees testing of several hundred thousand athletic blood and urine samples annually, of which 1-2% test positive. Measures using the Athlete Biological Passport suggest a higher mean prevalence of about 14% positive tests. Biological testing, however, likely fails to detect many cutting-edge doping techniques, and thus the true prevalence of doping remains unknown. We surveyed 2167 athletes at two sporting events: the 13th International Association of Athletics Federations Word Championships in Athletics (WCA) in Daegu, South Korea in August 2011 and the 12th Quadrennial Pan-Arab Games (PAG) in Doha, Qatar in December 2011. To estimate the prevalence of doping, we utilized a "randomized response technique," which guarantees anonymity for individuals when answering a sensitive question. We also administered a control question at PAG assessing past-year use of supplements. The estimated prevalence of past-year doping was 43.6% (95% confidence interval 39.4-47.9) at WCA and 57.1% (52.4-61.8) at PAG. The estimated prevalence of past-year supplement use at PAG was 70.1% (65.6-74.7%). Sensitivity analyses, assessing the robustness of these estimates under numerous hypothetical scenarios of intentional or unintentional noncompliance by respondents, suggested that we were unlikely to have overestimated the true prevalence of doping. Doping appears remarkably widespread among elite athletes, and remains largely unchecked despite current biological testing. The survey technique presented here will allow future investigators to generate continued reference estimates of the prevalence of doping.
Fabregas, N.; Ewig, S.; Torres, A.; El-Ebiary, M.; Ramirez, J.; de la Bellacasa, J. P.; Bauer, T.; Cabello, H.
1999-01-01
BACKGROUND—A study was undertaken to assess the diagnostic value of different clinical criteria and the impact of microbiological testing on the accuracy of clinical diagnosis of suspected ventilator associated pneumonia (VAP). METHODS—Twenty five deceased mechanically ventilated patients were studied prospectively. Immediately after death, multiple bilateral lung biopsy specimens (16 specimens/patient) were obtained for histological examination and quantitative lung cultures. The presence of both histological pneumonia and positive lung cultures was used as a reference test. RESULTS—The presence of infiltrates on the chest radiograph and two of three clinical criteria (leucocytosis, purulent secretions, fever) had a sensitivity of 69% and a specificity of 75%; the corresponding numbers for the clinical pulmonary infection score (CPIS) were 77% and 42%. Non-invasive as well as invasive sampling techniques had comparable values. The combination of all techniques achieved a sensitivity of 85% and a specificity of 50%, and these values remained virtually unchanged despite the presence of previous treatment with antibiotics. When microbiological results were added to clinical criteria, adequate diagnoses originating from microbiological results which might have corrected false positive and false negative clinical judgements (n = 5) were countered by a similar proportion of inadequate diagnoses (n =6). CONCLUSIONS—Clinical criteria had reasonable diagnostic values. CPIS was not superior to conventional clinical criteria. Non-invasive and invasive sampling techniques had diagnostic values comparable to clinical criteria. An algorithm guiding antibiotic treatment exclusively by microbiological results does not increase the overall diagnostic accuracy and carries the risk of undertreatment. PMID:10491448
Pernet, Cyril R.; Wilcox, Rand; Rousselet, Guillaume A.
2012-01-01
Pearson’s correlation measures the strength of the association between two variables. The technique is, however, restricted to linear associations and is overly sensitive to outliers. Indeed, a single outlier can result in a highly inaccurate summary of the data. Yet, it remains the most commonly used measure of association in psychology research. Here we describe a free Matlab(R) based toolbox (http://sourceforge.net/projects/robustcorrtool/) that computes robust measures of association between two or more random variables: the percentage-bend correlation and skipped-correlations. After illustrating how to use the toolbox, we show that robust methods, where outliers are down weighted or removed and accounted for in significance testing, provide better estimates of the true association with accurate false positive control and without loss of power. The different correlation methods were tested with normal data and normal data contaminated with marginal or bivariate outliers. We report estimates of effect size, false positive rate and power, and advise on which technique to use depending on the data at hand. PMID:23335907
Pernet, Cyril R; Wilcox, Rand; Rousselet, Guillaume A
2012-01-01
Pearson's correlation measures the strength of the association between two variables. The technique is, however, restricted to linear associations and is overly sensitive to outliers. Indeed, a single outlier can result in a highly inaccurate summary of the data. Yet, it remains the most commonly used measure of association in psychology research. Here we describe a free Matlab((R)) based toolbox (http://sourceforge.net/projects/robustcorrtool/) that computes robust measures of association between two or more random variables: the percentage-bend correlation and skipped-correlations. After illustrating how to use the toolbox, we show that robust methods, where outliers are down weighted or removed and accounted for in significance testing, provide better estimates of the true association with accurate false positive control and without loss of power. The different correlation methods were tested with normal data and normal data contaminated with marginal or bivariate outliers. We report estimates of effect size, false positive rate and power, and advise on which technique to use depending on the data at hand.
Three-dimensional engineered heart tissue from neonatal rat cardiac myocytes.
Zimmermann, W H; Fink, C; Kralisch, D; Remmers, U; Weil, J; Eschenhagen, T
2000-04-05
A technique is presented that allows neonatal rat cardiac myocytes to form spontaneously and coherently beating 3-dimensional engineered heart tissue (EHT) in vitro, either as a plane biconcaval matrix anchored at both sides on Velcro-coated silicone tubes or as a ring. Contractile activity was monitored in standard organ baths or continuously in a CO(2) incubator for up to 18 days (=26 days after casting). Long-term measurements showed an increase in force between days 8 and 18 after casting and stable forces thereafter. At day 10, the twitch amplitude (TA) of electrically paced EHTs (average length x width x thickness, 11 x 6 x 0.4 mm) was 0.51 mN at length of maximal force development (L(max)) and a maximally effective calcium concentration. EHTs showed typical features of neonatal rat heart: a positive force-length and a negative force-frequency relation, high sensitivity to calcium (EC(50) 0.24 mM), modest positive inotropic (increase in TA by 46%) and pronounced positive lusitropic effect of isoprenaline (decrease in twitch duration by 21%). Both effects of isoprenaline were sensitive to the muscarinic receptor agonist carbachol in a pertussis toxin-sensitive manner. Adenovirus-mediated gene transfer of beta-galactosidase into EHTs reached 100% efficiency. In summary, EHTs retain many of the physiological characteristics of rat cardiac tissue and allow efficient gene transfer with subsequent force measurement. Copyright 2000 John Wiley & Sons, Inc.
Guntupalli, Kalpalatha K; Alapat, Philip M; Bandi, Venkata D; Kushnir, Igal
2008-12-01
Computerized lung-sound analysis is a sensitive and quantitative method to identify wheezing by its typical pattern on spectral analysis. We evaluated the accuracy of the VRI, a multi-sensor, computer-based device with an automated technique of wheeze detection. The method was validated in 100 sound files from seven subjects with asthma or chronic obstructive pulmonary disease and seven healthy subjects by comparison of auscultation findings, examination of audio files, and computer detection of wheezes. Three blinded physicians identified 40 sound files with wheezes and 60 sound files without wheezes. Sensitivity and specificity were 83% and 85%, respectively. Negative predictive value and positive predictive value were 89% and 79%, respectively. Overall inter-rater agreement was 84%. False positive cases were found to contain sounds that simulate wheezes, such as background noises with high frequencies or strong noises from the throat that could be heard and identified without a stethoscope. The present findings demonstrate that the wheeze detection algorithm has good accuracy, sensitivity, specificity, negative predictive value and positive predictive value for wheeze detection in regional analyses with a single sensor and multiple sensors. Results are similar to those reported in the literature. The device is user-friendly, requires minimal patient effort, and, distinct from other devices, it provides a dynamic image of breath sound distribution with wheeze detection output in less than 1 minute.
NASA Technical Reports Server (NTRS)
Lampton, M.; Malina, R. F.
1976-01-01
A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, about 10 microns, allows individual MCP channels to be distinguished.
Surrogate markers of subtle renal injury in patients with visceral leishmaniasis.
Elnojomi, N A A; Musa, A M; Younis, B M; Elfaki, M E E; El-Hassan, A M; Khalil, E A G
2010-09-01
Sudanese visceral leishmaniasis (VL) is a disease of children that is characterized by fever, hepatosplenomegaly, lymphadenopathy, pancytopenia, and renal injury. Microalbuminuria (MA) and urinary retinol binding protein (urRBP) are useful markers for glomerular and tubular dysfunctions, respectively. We report the prevalence of subtle renal injury in 88 parasitologically confirmed VL patients in a cross-sectional and hospital-based study. Blood and urine were collected before treatment for hematological, biochemical profiles in addition to MA and urRBP measurement using competitive solid phase, sandwich enzyme-linked immune sorbent assay (ELISA), and immunoturbidometry. All the patients had normal serum urea and creatinine levels and no detectable urRBP. However, 40% of the patients had MA detected by ELISA, and 42% were reactive with turbidometry. The sensitivity, specificity, positive and negative predictive values for MA turbidometric technique were calculated as 100%; 96%; 95% and 100%, respectively. In conclusion; subtle renal injury in VL is mainly glomerular. Turbidometry for MA measurement is a simple, inexpensive, sensitive, and specific technique with high predictive values.
Simulation of the hybrid Tunka Advanced International Gamma-ray and Cosmic ray Astrophysics (TAIGA)
NASA Astrophysics Data System (ADS)
Kunnas, M.; Astapov, I.; Barbashina, N.; Beregnev, S.; Bogdanov, A.; Bogorodskii, D.; Boreyko, V.; Brückner, M.; Budnev, N.; Chiavassa, A.; Chvalaev, O.; Dyachok, A.; Epimakhov, S.; Eremin, T.; Gafarov, A.; Gorbunov, N.; Grebenyuk, V.; Gress, O.; Gress, T.; Grinyuk, A.; Grishin, O.; Horns, D.; Ivanova, A.; Karpov, N.; Kalmykov, N.; Kazarina, Y.; Kindin, V.; Kirichkov, N.; Kiryuhin, S.; Kokoulin, R.; Kompaniets, K.; Konstantinov, E.; Korobchenko, A.; Korosteleva, E.; Kozhin, V.; Kuzmichev, L.; Lenok, V.; Lubsandorzhiev, B.; Lubsandorzhiev, N.; Mirgazov, R.; Mirzoyan, R.; Monkhoev, R.; Nachtigall, R.; Pakhorukov, A.; Panasyuk, M.; Pankov, L.; Perevalov, A.; Petrukhin, A.; Platonov, V.; Poleschuk, V.; Popescu, M.; Popova, E.; Porelli, A.; Porokhovoy, S.; Prosin, V.; Ptuskin, V.; Romanov, V.; Rubtsov, G. I.; Müger; Rybov, E.; Samoliga, V.; Satunin, P.; Saunkin, A.; Savinov, V.; Semeney, Yu; Shaibonov (junior, B.; Silaev, A.; Silaev (junior, A.; Skurikhin, A.; Slunecka, M.; Spiering, C.; Sveshnikova, L.; Tabolenko, V.; Tkachenko, A.; Tkachev, L.; Tluczykont, M.; Veslopopov, A.; Veslopopova, E.; Voronov, D.; Wischnewski, R.; Yashin, I.; Yurin, K.; Zagorodnikov, A.; Zirakashvili, V.; Zurbanov, V.
2015-08-01
Up to several 10s of TeV, Imaging Air Cherenkov Telescopes (IACTs) have proven to be the instruments of choice for GeV/TeV gamma-ray astronomy due to their good reconstrucion quality and gamma-hadron separation power. However, sensitive observations at and above 100 TeV require very large effective areas (10 km2 and more), which is difficult and expensive to achieve. The alternative to IACTs are shower front sampling arrays (non-imaging technique or timing-arrays) with a large area and a wide field of view. Such experiments provide good core position, energy and angular resolution, but only poor gamma-hadron separation. Combining both experimental approaches, using the strengths of both techniques, could optimize the sensitivity to the highest energies. The TAIGA project plans to combine the non-imaging HiSCORE [8] array with small (∼10m2) imaging telescopes. This paper covers simulation results of this hybrid approach.
Yang, Jin-Lan; Liu, Li-Wang; Gong, Yi-Qin; Huang, Dan-Qiong; Wang, Feng; He, Ling-Li
2007-06-01
The level of cytosine methylation induced by cadmium in radish (Raphanus sativus L.) genome was analysed using the technique of methylation-sensitive amplified polymorphism (MSAP). The MSAP ratios in radish seedling exposed to cadmium chloride at the concentration of 50, 250 and 500 mg/L were 37%, 43% and 51%, respectively, and the control was 34%; the full methylation levels (C(m)CGG in double strands) were at 23%, 25% and 27%, respectively, while the control was 22%. The level of increase in MSAP and full methylation indicated that de novo methylation occurred in some 5'-CCGG sites under Cd stress. There was significant positive correlation between increase of total DNA methylation level and CdCl(2) concentration. Four types of MSAP patterns: de novo methylation, de-methylation, atypical pattern and no changes of methylation pattern were identified among CdCl(2) treatments and the control. DNA methylation alteration in plants treated with CdCl(2) was mainly through de novo methylation.
Soto, Marcelo A; Lu, Xin; Martins, Hugo F; Gonzalez-Herraez, Miguel; Thévenaz, Luc
2015-09-21
In this paper a technique to measure the distributed birefringence profile along optical fibers is proposed and experimentally validated. The method is based on the spectral correlation between two sets of orthogonally-polarized measurements acquired using a phase-sensitive optical time-domain reflectometer (ϕOTDR). The correlation between the two measured spectra gives a resonance (correlation) peak at a frequency detuning that is proportional to the local refractive index difference between the two orthogonal polarization axes of the fiber. In this way the method enables local phase birefringence measurements at any position along optical fibers, so that any longitudinal fluctuation can be precisely evaluated with metric spatial resolution. The method has been experimentally validated by measuring fibers with low and high birefringence, such as standard single-mode fibers as well as conventional polarization-maintaining fibers. The technique has potential applications in the characterization of optical fibers for telecommunications as well as in distributed optical fiber sensing.
Multiplexed wavelet transform technique for detection of microcalcification in digitized mammograms.
Mini, M G; Devassia, V P; Thomas, Tessamma
2004-12-01
Wavelet transform (WT) is a potential tool for the detection of microcalcifications, an early sign of breast cancer. This article describes the implementation and evaluates the performance of two novel WT-based schemes for the automatic detection of clustered microcalcifications in digitized mammograms. Employing a one-dimensional WT technique that utilizes the pseudo-periodicity property of image sequences, the proposed algorithms achieve high detection efficiency and low processing memory requirements. The detection is achieved from the parent-child relationship between the zero-crossings [Marr-Hildreth (M-H) detector] /local extrema (Canny detector) of the WT coefficients at different levels of decomposition. The detected pixels are weighted before the inverse transform is computed, and they are segmented by simple global gray level thresholding. Both detectors produce 95% detection sensitivity, even though there are more false positives for the M-H detector. The M-H detector preserves the shape information and provides better detection sensitivity for mammograms containing widely distributed calcifications.
Alvarado, Primavera; Ostos, Ana; Franquiz, Nohelys; Roschman-González, Antonio; Zambrano, Edgar A; Mendoza, Mireya
2015-06-01
We developed and analyzed an Enzyme-Linked Immunosorbent Assay (ELISA) in order to detect antibodies in sera from sporotrichosis patients. We used a crude antigen of Sporothrix schenckii sensu stricto, obtained from the mycelial phase of the fungi. Positive sera were analyzed by other serological techniques such as double immunodiffusion (IGG) and counterimmunoelectrophoresis (CIE). The assay was validated by using sera from patients with other pathologies such as: histoplasmosis, paracoccidioidomycosis, tuberculosis, leishmaniasis, lupus and healthy individuals as negative controls. For the Sporothrix schenckii sensu stricto antigen, we found a 100% of specificity by every technique and sensitivity higher than 98% with IDD, CIE and ELISA. Our results show a high sensitivity and specificity for the Sporothrix schenckii sensu stricto antigen, so it can be used for IDD, CIE and ELISA. The results suggest that this antigen could be used in conjunction with other conventional tests for differential diagnosis and may be useful for monitoring the disease progression and response to treatment.
Chen, Min-Cheng; Chen, Hao-Yu; Lin, Chia-Yi; Chien, Chao-Hsin; Hsieh, Tsung-Fan; Horng, Jim-Tong; Qiu, Jian-Tai; Huang, Chien-Chao; Ho, Chia-Hua; Yang, Fu-Liang
2012-01-01
This paper reports a versatile nano-sensor technology using “top-down” poly-silicon nanowire field-effect transistors (FETs) in the conventional Complementary Metal-Oxide Semiconductor (CMOS)-compatible semiconductor process. The nanowire manufacturing technique reduced nanowire width scaling to 50 nm without use of extra lithography equipment, and exhibited superior device uniformity. These n type polysilicon nanowire FETs have positive pH sensitivity (100 mV/pH) and sensitive deoxyribonucleic acid (DNA) detection ability (100 pM) at normal system operation voltages. Specially designed oxide-nitride-oxide buried oxide nanowire realizes an electrically Vth-adjustable sensor to compensate device variation. These nanowire FETs also enable non-volatile memory application for a large and steady Vth adjustment window (>2 V Programming/Erasing window). The CMOS-compatible manufacturing technique of polysilicon nanowire FETs offers a possible solution for commercial System-on-Chip biosensor application, which enables portable physiology monitoring and in situ recording. PMID:22666012
Atif, M; Farooq, W A; Fatehmulla, Amanullah; Aslam, M; Ali, Syed Mansoor
2015-01-19
Cadmium sulphide (CdS) quantum dot sensitized solar cells (QDSSCs) based on screen-printed TiO₂ were assembled using a screen-printing technique. The CdS quantum dots (QDs) were grown by using the Successive Ionic Layer Adsorption and Reaction (SILAR) method. The optical properties were studied by UV-Vis absorbance spectroscopy. Photovoltaic characteristics and impedance spectroscopic measurements of CdS QDSSCs were carried out under air mass 1.5 illuminations. The experimental results of capacitance against voltage indicate a trend from positive to negative capacitance because of the injection of electrons from the Fluorine doped tin oxide (FTO) electrode into TiO₂.
Aerial Radiological Measuring System (ARMS): systems, procedures and sensitivity (1976)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyns, P K
1976-07-01
This report describes the Aerial Radiological Measuring System (ARMS) designed and operated by EG and G, Inc., for the Energy Research and Development Administration's (ERDA) Division of Operational Safety with the cooperation of the Nuclear Regulatory Commission. Designed to rapidly survey large areas for low-level man-made radiation, the ARMS has also proven extremely useful in locating lost radioactive sources of relatively low activity. The system consists of sodium iodide scintillation detectors, data formatting and recording equipment, positioning equipment, meteorological instruments, direct readout hardware, and data analysis equipment. The instrumentation, operational procedures, data reduction techniques and system sensitivities are described, togethermore » with their applications and sample results.« less
Testing of a technique for remotely measuring water salinity in an estuarine environment
NASA Technical Reports Server (NTRS)
Thomann, G. C.
1975-01-01
An aircraft experiment was flown on November 7, 1973 to test a technique for remote water salinity measurement. Apparent temperatures at 21 cm and 8-14 micron wavelengths were recorded on eight runs over a line along which the salinity varied from 5 to 30%. Boat measurements were used for calibration and accuracy calculations. Overall RMS accuracy over the complete range of salinities was 3.6%. Overall RMS accuracy for salinities greater than 10%, where the technique is more sensitive, was 2.6%. Much of this error is believed to be due to inability to exactly locate boat and aircraft positions. The standard deviation over the eight runs for salinities or = 10% is 1.4%; this error contains a component due to mislocation of the aircraft also. It is believed that operational use of the technique is possible with accuracies of 1-2%.
NASA Astrophysics Data System (ADS)
Ganesan, A. R.; Arulmozhivarman, P.; Jesson, M.
2005-12-01
Accurate surface metrology and transmission characteristics measurements have become vital to certify the manufacturing excellence in the field of glass visors, windshields, menu boards and transportation industries. We report a simple, cost-effective and novel technique for the measurement of geometric aberrations in transparent materials such as glass sheets, Perspex, etc. The technique makes use of an array of spot pattern, we call the spot pattern test chart technique, in the diffraction limited imaging position having large field of view. Performance features include variable angular dynamic range and angular sensitivity. Transparent sheets as the intervening medium introduced in the line of sight, causing aberrations, are estimated in real time using the Zernike reconstruction method. Quantitative comparative analysis between a Shack-Hartmann wavefront sensor and the proposed new method is presented and the results are discussed.
Comparison of different diagnostic techniques for the detection of cryptosporidiosis in bovines
Rekha, K. M. H.; Puttalakshmamma, G. C.; D’Souza, Placid E.
2016-01-01
Aim: Aim of the present study was to compare different methods, viz., Sheather's sugar flotation (SSF), Ziehl-Neelsen (ZN), Kinyoun's acid-fast method (KAF), safranin-methylene blue staining (SMB), and negative staining techniques such as nigrosin staining, light green staining, and malachite green staining for the detection of Cryptosporidium spp. oocysts in bovines. Materials and Methods: A total of 455 fecal samples from bovines were collected from private, government farms and from the clinical cases presented to Department of Medicine, Veterinary College, Bengaluru. They were subjected for SSF, ZN, KAF, SMB and negative staining methods. Results: Out of 455 animal fecal samples screened 5.71% were found positive for Cryptosporidium spp. oocysts. The species were identified as Cryptosporidium parvum in calves and Cryptosporidium andersoni in adults based on the morphological characterization and micrometry of the oocysts. Conclusions: Of all the techniques, fecal flotation with sheather's was found to be more specific and sensitive method for the detection of Cryptosporidium spp. oocysts. Among the conventional staining methods, the SMB gives better differentiation between oocysts and yeast. Among the three negative staining methods, malachite green was found sensitive over the other methods. PMID:27051211
NASA Astrophysics Data System (ADS)
Giovinazzo, G.; Ribas, N.; Cinca, J.; Rosell-Ferrer, J.
2010-04-01
Previous studies have shown that it is possible to evaluate heart graft rejection level using a bioimpedance technique by means of an intracavitary catheter. However, this technique does not present relevant advantages compared to the gold standard for the detection of a heart rejection, which is the biopsy of the endomyocardial tissue. We propose to use a less invasive technique that consists in the use of a transoesophageal catheter and two standard ECG electrodes on the thorax. The aim of this work is to evaluate different parameters affecting the impedance measurement, including: sensitivity to electrical conductivity and permittivity of different organs in the thorax, lung edema and pleural water. From these results, we deduce the best estimator for cardiac rejection detection, and we obtain the tools to identify possible cases of false positive of heart rejection due to other factors. To achieve these objectives we have created a thoracic model and we have simulated, with a FEM program, different situations at the frequencies of 13, 30, 100, 300 and 1000 kHz. Our simulation demonstrates that the phase, at 100 and 300 kHz, has the higher sensitivity to changes in the electrical parameters of the heart muscle.
García, Patricia; Balcells, M Elvira; Castillo, Claudia; Miranda, Carolina; Geoffroy, Enrique; Román, Juan C; Wozniak, Aniela
2017-08-01
Extra-pulmonary tuberculosis (TB) represents the 26.2% of total TB cases in Chile. Culture is the gold standard method, but the process is extremely slow. Xpert®MTB/RIF technique detects Mycobacterium tuberculosis complex (MTBc) through real time PCR in less than 3 h. However, it has been validated only for respiratory specimens. We aimed to determine the performance of Xpert®MTB/RIF test in detecting MTBc in extra-respiratory specimens compared with a combined gold standard consisting in a positive (liquid and solid) mycobacterial culture and/or a positive validated molecular method (q-RPC, Cobas®TaqMan®-MTB). Fifty extra-respiratory specimens were analyzed, from which 25 were positive and 25 negative for MTBc based on the combined gold standard. The 25 positive specimens had a positive result by Xpert®MTB/RIF; from the 25 negative specimens, 24 had a negative result and one had a positive result. We obtained an overall concordance of 98% between Xpert®MTB/RIF and the combined gold standard. Xpert®MTB/RIF test was able to detect 12 smear-negative specimens and 3 culture-negative specimens, all of them corresponding to extra-pulmonary TB cases. Xpert®MTB/RIF showed similar sensitivity to q-RPC in detecting MTBc in extra-respiratory specimens. This procedure allowed a substantial reduction in the time of diagnosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamal, I., E-mail: imtiaz-kamal26@yahoo.com; Yunus, S. M., E-mail: yunussm11@yahoo.com; Datta, T. K., E-mail: tk-datta4@yahoo.com
2016-07-12
A high performance neutron diffractometer called Savar Neutron Diffractometer (SAND) was built and installed at radial beam port-2 of TRIGA Mark II research reactor at AERE, Savar, Dhaka, Bangladesh. Structural studies of materials are being done by this technique to characterize materials crystallograpohically and magnetically. The micro-structural information obtainable by neutron scattering method is very essential for determining its technological applications. This technique is unique for understanding the magnetic behavior in magnetic materials. Ceramic, steel, electronic and electric industries can be benefited from this facility for improving their products and fabrication process. This instrument consists of a Popovicimonochromator with amore » large linear position sensitive detector array. The monochromator consists of nine blades of perfect single crystal of silicon with 6 mm thickness each. The monochromator design was optimized to provide maximum flux on 3 mm diameter cylindrical sample with a relatively flat angular dependence of resolution. Five different wave lengths can be selected by orienting the crystal at various angles. A sapphire filter was used before the primary collimator to minimize the first neutron. The detector assembly is composed of 15 linear position sensitive proportional counters placed at either 1.1 m or 1.6 m from the sample position and enclosed in a air pad supported high density polythene shield. Position sensing is obtained by charge division using 1-wide NIM position encoding modules (PEM). The PEMs communicate with the host computer via USB. The detector when placed at 1.1 m, subtends 30° (2θ) at each step and covers 120° in 4 steps. When the detector is placed at 1.6 m it subtends 20° at each step and covers 120° in 6 steps. The instrument supports both low and high temperature sample environment. The instrument supports both low and high temperature sample environment. The diffractometer is a state-of-the art technology for diffraction study in our country.« less
NASA Astrophysics Data System (ADS)
Kamal, I.; Yunus, S. M.; Datta, T. K.; Zakaria, A. K. M.; Das, A. K.; Aktar, S.; Hossain, S.; Berliner, R.; Yelon, W. B.
2016-07-01
A high performance neutron diffractometer called Savar Neutron Diffractometer (SAND) was built and installed at radial beam port-2 of TRIGA Mark II research reactor at AERE, Savar, Dhaka, Bangladesh. Structural studies of materials are being done by this technique to characterize materials crystallograpohically and magnetically. The micro-structural information obtainable by neutron scattering method is very essential for determining its technological applications. This technique is unique for understanding the magnetic behavior in magnetic materials. Ceramic, steel, electronic and electric industries can be benefited from this facility for improving their products and fabrication process. This instrument consists of a Popovicimonochromator with a large linear position sensitive detector array. The monochromator consists of nine blades of perfect single crystal of silicon with 6mm thickness each. The monochromator design was optimized to provide maximum flux on 3mm diameter cylindrical sample with a relatively flat angular dependence of resolution. Five different wave lengths can be selected by orienting the crystal at various angles. A sapphire filter was used before the primary collimator to minimize the first neutron. The detector assembly is composed of 15 linear position sensitive proportional counters placed at either 1.1 m or 1.6 m from the sample position and enclosed in a air pad supported high density polythene shield. Position sensing is obtained by charge division using 1-wide NIM position encoding modules (PEM). The PEMs communicate with the host computer via USB. The detector when placed at 1.1 m, subtends 30˚ (2θ) at each step and covers 120˚ in 4 steps. When the detector is placed at 1.6 m it subtends 20˚ at each step and covers 120˚ in 6 steps. The instrument supports both low and high temperature sample environment. The instrument supports both low and high temperature sample environment. The diffractometer is a state-of-the art technology for diffraction study in our country.
Nunes, Marta C; Soofie, Nasiha; Downs, Sarah; Tebeila, Naume; Mudau, Azwi; de Gouveia, Linda; Madhi, Shabir A
2016-12-01
Advances in molecular laboratory techniques are changing the landscape of Bordetella pertussis illness diagnosis. Polymerase chain reaction (PCR) assays have greatly improved the sensitivity detection and the turnaround time to diagnosis compared to culture. Moreover, different respiratory specimens, such as flocked nasopharyngeal swabs (NPSs), nasopharyngeal aspirates (NPAs), and induced sputum, have been used for B. pertussis detection, although there is limited head-to-head comparison to evaluating the PCR yield from the 3 sampling methods. Hospitalized infants <6 months of age who fulfilled a broad syndromic criteria of respiratory illness were tested for B. pertussis infection by PCR on paired NPSs and NPAs; or paired NPSs and induced sputum. An exploratory analysis of B. pertussis culture was performed on induced sputum specimens and in a subset of NPSs. From November 2014 to May 2015, 484 infants with paired NPSs and NPAs were tested; 15 (3.1%) PCR-confirmed pertussis cases were identified, 13 of which were PCR positive on both samples, while 1 each were positive only on NPS or NPA. From March to October 2015, 320 infants had NPSs and induced sputum collected, and 11 (3.4%) pertussis cases were identified by PCR, including 8 (72.7%) positive on both samples, 1 (9.1%) only positive on NPS, and 2 (18.2%) only positive on induced sputum. The 3 types of specimens had similar negative predictive value >99% and sensitivity >83%. Compared to PCR, culture sensitivity was 60% in induced sputum and 40% in NPSs. Flocked nasopharyngeal swabs, nasopharyngeal aspirates, and induced sputum performed similarly for the detection of B. pertussis infection in young infants by PCR. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America.
Nunes, Marta C.; Soofie, Nasiha; Downs, Sarah; Tebeila, Naume; Mudau, Azwi; de Gouveia, Linda; Madhi, Shabir A.
2016-01-01
Background. Advances in molecular laboratory techniques are changing the landscape of Bordetella pertussis illness diagnosis. Polymerase chain reaction (PCR) assays have greatly improved the sensitivity detection and the turnaround time to diagnosis compared to culture. Moreover, different respiratory specimens, such as flocked nasopharyngeal swabs (NPSs), nasopharyngeal aspirates (NPAs), and induced sputum, have been used for B. pertussis detection, although there is limited head-to-head comparison to evaluating the PCR yield from the 3 sampling methods. Methods. Hospitalized infants <6 months of age who fulfilled a broad syndromic criteria of respiratory illness were tested for B. pertussis infection by PCR on paired NPSs and NPAs; or paired NPSs and induced sputum. An exploratory analysis of B. pertussis culture was performed on induced sputum specimens and in a subset of NPSs. Results. From November 2014 to May 2015, 484 infants with paired NPSs and NPAs were tested; 15 (3.1%) PCR-confirmed pertussis cases were identified, 13 of which were PCR positive on both samples, while 1 each were positive only on NPS or NPA. From March to October 2015, 320 infants had NPSs and induced sputum collected, and 11 (3.4%) pertussis cases were identified by PCR, including 8 (72.7%) positive on both samples, 1 (9.1%) only positive on NPS, and 2 (18.2%) only positive on induced sputum. The 3 types of specimens had similar negative predictive value >99% and sensitivity >83%. Compared to PCR, culture sensitivity was 60% in induced sputum and 40% in NPSs. Conclusions. Flocked nasopharyngeal swabs, nasopharyngeal aspirates, and induced sputum performed similarly for the detection of B. pertussis infection in young infants by PCR. PMID:27838671
Ablordeppey, Enyo A; Drewry, Anne M; Beyer, Alexander B; Theodoro, Daniel L; Fowler, Susan A; Fuller, Brian M; Carpenter, Christopher R
2017-04-01
We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared with chest radiography. PubMed, Embase, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov. Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2 × 2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, interrater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Fifteen studies with 1,553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 (0.77-0.86) and 0.98 (0.97-0.99), respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 (14.72-65.78) and 0.25 (0.13-0.47). The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than chest radiography.
Automatic detection of lung vessel bifurcation in thoracic CT images
NASA Astrophysics Data System (ADS)
Maduskar, Pragnya; Vikal, Siddharth; Devarakota, Pandu
2011-03-01
Computer-aided diagnosis (CAD) systems for detection of lung nodules have been an active topic of research for last few years. It is desirable that a CAD system should generate very low false positives (FPs) while maintaining high sensitivity. This work aims to reduce the number of false positives occurring at vessel bifurcation point. FPs occur quite frequently on vessel branching point due to its shape which can appear locally spherical due to the intrinsic geometry of intersecting tubular vessel structures combined with partial volume effects and soft tissue attenuation appearance surrounded by parenchyma. We propose a model-based technique for detection of vessel branching points using skeletonization, followed by branch-point analysis. First we perform vessel structure enhancement using a multi-scale Hessian filter to accurately segment tubular structures of various sizes followed by thresholding to get binary vessel structure segmentation [6]. A modified Reebgraph [7] is applied next to extract the critical points of structure and these are joined by a nearest neighbor criterion to obtain complete skeletal model of vessel structure. Finally, the skeletal model is traversed to identify branch points, and extract metrics including individual branch length, number of branches and angle between various branches. Results on 80 sub-volumes consisting of 60 actual vessel-branching and 20 solitary solid nodules show that the algorithm identified correctly vessel branching points for 57 sub-volumes (95% sensitivity) and misclassified 2 nodules as vessel branch. Thus, this technique has potential in explicit identification of vessel branching points for general vessel analysis, and could be useful in false positive reduction in a lung CAD system.
Praxedes, M K; De Oliveira, L Z; Pereira, W da V; Quintana, I Z; Tabak, D G; De Oliveira, M S
1994-01-01
The enzyme myeloperoxidase (MPO) is the most specific marker of myeloid lineage. The recognition of acute myeloid leukaemia (AML) with minimally differentiation (AML-M0) is established with methods that include myeloid markers CD13/CD33 and detection of MPO in blast cells by immunological techniques or electron microscopy cytochemistry (EM). We have analysed the presence of MPO in leukaemic blast cells by conventional cytochemistry and immunological methods using a monoclonal antibody anti-MPO (CLB-MPO1) in 121 cases of acute leukaemia. The aim of the study was to investigate the sensitivity of this McAb to identify AML-M0, as CD13/CD33 can be expressed in some cases of acute lymphoblastic leukaemia (ALL) and EM cytochemistry is not always available in many laboratories. Anti-MPO was positive in all cases of AML (M1-M5) which were positive by Sudan Black B reaction in similar or higher percentage ratio for each case, although in some of them did not label with CD13/CD33 tested by IF and IPc techniques. Based on the anti-MPO positivity, 5 out of 10 cases called undifferentiated leukaemia (AUL) were reclassified as AML-M0, though 4 cases were CD13/CD33 negative. Furthermore, after analysing the anti-MPO expression among 32 cases of ALL, we had to reclassify four of them as acute biphenotypic leukaemia. We conclude that anti-MPO is a very sensitive and reliable tool in AML diagnosis and has an important role in distinguishing minimally differentiated AML and biphenotypic acute leukaemia from AUL and ALL.
Shinu, Pottathil; AshokKumar Singh, Varsha; Nair, Anroop; Farooq, Rumana; Ishaq, Sheikh
2016-09-01
The aim of this study was to evaluate the difference in the rate of recovery of Mycobacterium tuberculosis (MTB) from routinely cultured sputum and long-term stored sputum specimens (at -80°C) using Löwenstein-Jensen (LJ) media, Mycobacterium Growth Indicator Tube (BBL MGIT(TM) ), and Middlebrook 7H11 (MB 7H11) agar. Direct acid-fast bacilli smear-positive sputum specimens (both before and after storage [n = 136]) were studied (after culturing on LJ media, BBL MGIT(TM) , and MB 7H11 agar) and the performances were compared. For the detection of MTB, BBL MGIT(TM) and MB 7H11 agar (before storage) demonstrated a sensitivity, specificity, positive predictive value (PPV) of 98.28%, 30.77%, 92.68%, 66.67%, and negative predictive value (NPV) of 97.41%, 30.77%, 92.62%, 57.14%, respectively, when compared to LJ media (before storage). Similarly, BBL MGIT(TM) and MB 7H11 agar (after storage) demonstrated a sensitivity, specificity, PPV, and NPV of 95.5%, 38.89%, 90.6%, 58.33%, and 95.5%, 66.67 %, 94.64%, 70.59%, respectively, when compared to LJ media (after storage) for the detection of MTB. None of the culture techniques independently (both before and after storage) detected growth of MTB from all the sputum specimens studied. However, BBL MGIT(TM) system and LJ media combination (both before and after storage) effectively detected the growth of MTB from sputum specimens when compared to other culture technique combinations. © 2015 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Sinha, D.; De, D.; Ayaz, A.
2018-03-01
Environmental friendly natural dye curcumin extracted from low-cost Curcumina longa stem is used as a photo-sensitizer for the fabrication of ZnO-based dye-sensitized solar cells (DSSC). Nanostructured ZnO is fabricated on a transparent conducting glass (TCO), using a cost-effective chemical bath deposition technique. Scanning electron microscopic images show hexagonal patterned ZnO nano-towers decorated with several nanosteps. The average length of ZnO nano-tower is 5 μm and diameter is 1.2 μm. The UV-Vis spectroscopic study of the curcumin dye is used to understand the light absorption behavior as well as band gap energy of the extracted natural dye. The dye shows wider absorption band-groups over 350-470 nm and 500-600 nm with two peaks positioned at 425 nm and 525 nm. The optical band gap energy and energy band position of the dye is derived which supports its stability and high electron affinity that makes it suitable for light harvesting and effortless electron transfer from dye to the semiconductor or interface between them. FTIR spectrum of curcumin dye-sensitized ZnO-based DSSC shows the presence of anchoring groups and colouring constitutes. The I-V and P-V curves of the fabricated DSSC are measured under simulated light (100 mW/cm2). The highest visible light to electric conversion efficiency of 0.266% (using ITO) and 0.33% (using FTO) is achieved from the curcumin dye-sensitized cell.
Cunningham, Gregory; Seghrouchni, Khalid; Ruffieux, Etienne; Vaudaux, Pierre; Gayet-Ageron, Angèle; Cherkaoui, Abdessalam; Godinho, Eduardo; Lew, Daniel; Hoffmeyer, Pierre; Uçkay, Ilker
2014-06-01
The sensitivity of Gram staining is known to be suboptimal for the diagnosis of native joint septic arthritis. We lack information about the accuracy of Gram compared to other microscopic staining techniques for predicting infection in different patient populations. This was a cohort study with cost evaluations at the Orthopaedic Service of Geneva University Hospitals (January 1996-October 2012). Among 500 episodes of arthritis (196 with immunosuppression, 227 with underlying arthroplasties and 69 with gout or other crystals in synovial fluid), Gram staining revealed pathogens in 146 episodes (146/500, 29 %) or in 146 of the 400 culture-positive episodes (37 %). Correlation between the Gram and acridine staining of the same sample was good (Spearman 0.85). Overall, the sensitivity, specificity, positive predictive value and negative predictive value of Gram stain for rapid diagnosis of septic arthritis was 0.37, 0.99, 0.99 and 0.28, respectively, compared to microbiological cultures. Quite similar values were recorded across the different patient subpopulations, in particular for sensitivity values that were 0.33 for patients with prosthetic joint infections, 0.40 for immunosuppressed patients, 0.36 for patients under antibiotic administration and 0.52 for patients with concomitant crystalline disease. The sensitivity of Gram or acridine orange staining for a rapid diagnosis of episodes of septic arthritis is suboptimal compared to microbiological culture, regardless of underlying conditions, immunosuppression or antibiotic therapy. The sensitivity in the presence of synovial fluid crystals is moderate. Acridine orange and Gram stains are equivalent.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, L.; Lanza, R.C.
1999-12-01
The authors have developed a near field coded aperture imaging system for use with fast neutron techniques as a tool for the detection of contraband and hidden explosives through nuclear elemental analysis. The technique relies on the prompt gamma rays produced by fast neutron interactions with the object being examined. The position of the nuclear elements is determined by the location of the gamma emitters. For existing fast neutron techniques, in Pulsed Fast Neutron Analysis (PFNA), neutrons are used with very low efficiency; in Fast Neutron Analysis (FNS), the sensitivity for detection of the signature gamma rays is very low.more » For the Coded Aperture Fast Neutron Analysis (CAFNA{reg{underscore}sign}) the authors have developed, the efficiency for both using the probing fast neutrons and detecting the prompt gamma rays is high. For a probed volume of n{sup 3} volume elements (voxels) in a cube of n resolution elements on a side, they can compare the sensitivity with other neutron probing techniques. As compared to PFNA, the improvement for neutron utilization is n{sup 2}, where the total number of voxels in the object being examined is n{sup 3}. Compared to FNA, the improvement for gamma-ray imaging is proportional to the total open area of the coded aperture plane; a typical value is n{sup 2}/2, where n{sup 2} is the number of total detector resolution elements or the number of pixels in an object layer. It should be noted that the actual signal to noise ratio of a system depends also on the nature and distribution of background events and this comparison may reduce somewhat the effective sensitivity of CAFNA. They have performed analysis, Monte Carlo simulations, and preliminary experiments using low and high energy gamma-ray sources. The results show that a high sensitivity 3-D contraband imaging and detection system can be realized by using CAFNA.« less
High-Speed Microscale Optical Tracking Using Digital Frequency-Domain Multiplexing.
Maclachlan, Robert A; Riviere, Cameron N
2009-06-01
Position-sensitive detectors (PSDs), or lateral-effect photodiodes, are commonly used for high-speed, high-resolution optical position measurement. This paper describes the instrument design for multidimensional position and orientation measurement based on the simultaneous position measurement of multiple modulated sources using frequency-domain-multiplexed (FDM) PSDs. The important advantages of this optical configuration in comparison with laser/mirror combinations are that it has a large angular measurement range and allows the use of a probe that is small in comparison with the measurement volume. We review PSD characteristics and quantitative resolution limits, consider the lock-in amplifier measurement system as a communication link, discuss the application of FDM to PSDs, and make comparisons with time-domain techniques. We consider the phase-sensitive detector as a multirate DSP problem, explore parallels with Fourier spectral estimation and filter banks, discuss how to choose the modulation frequencies and sample rates that maximize channel isolation under design constraints, and describe efficient digital implementation. We also discuss hardware design considerations, sensor calibration, probe construction and calibration, and 3-D measurement by triangulation using two sensors. As an example, we characterize the resolution, speed, and accuracy of an instrument that measures the position and orientation of a 10 mm × 5 mm probe in 5 degrees of freedom (DOF) over a 30-mm cube with 4-μm peak-to-peak resolution at 1-kHz sampling.
Relative efficacy for radiation reducing methods in scoliotic patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aikenhead, J.; Triano, J.; Baker, J.
Radiation dosages to sensitive organs in full spine radiography have in recent years been a concern of physicians as well as the general public. The spine is the prime target for exposure in scoliosis radiography, though the exposure usually necessitates irradiation of several radio-sensitive organs. In recent studies, various protection techniques have been used including various lead and aluminum filtration systems, altered patient positioning and varied tube-film distances. The purpose of this study was to evaluate the efficiency for radiation dosage reduction of three filtration systems used frequently in the chiropractic profession. The systems tested were the Nolan Multiple X-raymore » Filters, the Clear-Pb system and the Sportelli Wedge system. These systems were tested in seven configurations varying breast shielding, distance and patient positioning. All systems tested demonstrated significant radiation reductions to organs, especially breast tissue. The Clear-Pb system appeared to be the most effective for all organs except the breast, and the Sportelli Wedge system demonstrated the greatest reduction to breast tissue.« less
Direct interaction with an assistive robot for individuals with chronic stroke.
Kmetz, Brandon; Markham, Heather; Brewer, Bambi R
2011-01-01
Many robotic systems have been developed to provide assistance to individuals with disabilities. Most of these systems require the individual to interact with the robot via a joystick or keypad, though some utilize techniques such as speech recognition or selection of objects with a laser pointer. In this paper, we describe a prototype system using a novel method of interaction with an assistive robot. A touch-sensitive skin enables the user to directly guide a robotic arm to a desired position. When the skin is released, the robot remains fixed in position. The target population for this system is individuals with hemiparesis due to chronic stroke. The system can be used as a substitute for the paretic arm and hand in bimanual tasks such as holding a jar while removing the lid. This paper describes the hardware and software of the prototype system, which includes a robotic arm, the touch-sensitive skin, a hook-style prehensor, and weight compensation and speech recognition software.
Sarink, M J; Koelewijn, R; Slingerland, B C G C; Tielens, A G M; van Genderen, P J J; van Hellemond, J J
2018-06-28
Diagnosis of cystic echinococcosis (CE) is at present mainly based on imaging techniques. Serology has a complementary role, partly due to the small number of standardized and commercially available assays. Therefore we examined the clinical performance of the SERION ELISA classic Echinococcus IgG test. Using 10 U/ml as a cut-off point, and serum samples from 50 CE patients and 105 healthy controls, the sensitivity and specificity were 98.0% and 96.2%, respectively. If patients with other infectious diseases were used as negative controls, the specificity decreased to 76.9%, which causes poor positive predictive values. However, if results between 10 and 15 U/ml are classified as indecisive, the specificity of positive results (≥15 U/ml) increased to 92.5% without greatly affecting the sensitivity (92.0%). Using this approach in combination with imaging studies, the SERION ELISA classic Echinococcosis IgG test can be a useful aid in the diagnosis of CE.
Setterington, Emma B.; Alocilja, Evangelyn C.
2012-01-01
Biological defense and security applications demand rapid, sensitive detection of bacterial pathogens. This work presents a novel qualitative electrochemical detection technique which is applied to two representative bacterial pathogens, Bacillus cereus (as a surrogate for B. anthracis) and Escherichia coli O157:H7, resulting in detection limits of 40 CFU/mL and 6 CFU/mL, respectively, from pure culture. Cyclic voltammetry is combined with immunomagnetic separation in a rapid method requiring approximately 1 h for presumptive positive/negative results. An immunofunctionalized magnetic/polyaniline core/shell nano-particle (c/sNP) is employed to extract target cells from the sample solution and magnetically position them on a screen-printed carbon electrode (SPCE) sensor. The presence of target cells significantly inhibits current flow between the electrically active c/sNPs and SPCE. This method has the potential to be adapted for a wide variety of target organisms and sample matrices, and to become a fully portable system for routine monitoring or emergency detection of bacterial pathogens. PMID:25585629
Tait, Brian D.
2016-01-01
This review outlines the development of human leukocyte antigen (HLA) antibody detection assays and their use in organ transplantation in both antibody screening and crossmatching. The development of sensitive solid phase assays such as the enzyme-linked immunosorbent assay technique, and in particular the bead-based technology has revolutionized this field over the last 10–15 years. This revolution however has created a new paradigm in clinical decision making with respect to the detection of low level pretransplant HLA sensitization and its clinical relevance. The relative sensitivities of the assays used are discussed and the relevance of conflicting inter-assay results. Each assay has its advantages and disadvantages and these are discussed. Over the last decade, the bead-based assay utilizing the Luminex® fluorocytometer instrument has become established as the “gold standard” for HLA antibody testing. However, there are still unresolved issues surrounding this technique, such as the presence of denatured HLA molecules on the beads which reveal cryptic epitopes and the issue of appropriate fluorescence cut off values for positivity. The assay has been modified to detect complement binding (CB) in addition to non-complement binding (NCB) HLA antibodies although the clinical relevance of the CB and NCB IgG isotypes is not fully resolved. The increase sensitivity of the Luminex® bead assay over the complement-dependent cytotoxicity crossmatch has permitted the concept of the “virtual crossmatch” whereby the crossmatch is predicted to a high degree of accuracy based on the HLA antibody specificities detected by the solid phase assay. Dialog between clinicians and laboratory staff on an individual patient basis is essential for correct clinical decision making based on HLA antibody results obtained by the various techniques. PMID:28018342
Starkey, Jean R; Makarov, Nikolay S; Drobizhev, Mikhail; Rebane, Aleksander
2012-07-01
We describe novel imaging protocols that allow detection of small cancer cell colonies deep inside tissue phantoms with high sensitivity and specificity. We compare fluorescence excited in Styryl-9M molecules by femtosecond pulses at near IR wavelengths, where Styryl-9M shows the largest dependence of the two-photon absorption (2PA) cross section on the local environment. We show that by calculating the normalized ratio of the two-photon excited fluorescence (2PEF) intensity at 1200 nm and 1100 nm excitation wavelengths we can achieve high sensitivity and specificity for determining the location of cancer cells surrounded by normal cells. The 2PEF results showed a positive correlation with the levels of MDR1 proteins expressed by the cells, and, for high MDR1 expressors, as few as ten cancer cells could be detected. Similar high sensitivity is also demonstrated for tumor colonies induced in mouse external ears. This technique could be useful in early cancer detection, and, perhaps, also in monitoring dormant cancer deposits.
Wu, Xiaoxin; Wang, Yeping; Weng, Tianhao; Hu, Chenyu; Wang, Frederick X.C.; Wu, Zhigang; Yu, Dongshan; Lu, Huoquan; Yao, Hangping
2017-01-01
Abstract The early secreted protein early secretory antigenic target 6(ESAT-6) and the culture filtrate protein 10 (CFP-10) are 2 antigens that are specific to Mycobacterium tuberculosis. These 2 antigens are good targets for tuberculosis (TB) detection. To rapidly diagnose TB across a variety of samples, we developed colloidal gold immunochromatographic strips (ICSs) based on ESAT-6 and CFP-10. The strips were evaluated using 233 samples, including sputum, plasma, and pleural effusion samples. The positive detection rates for ICSs for ESAT-6 and CFP-10 in sputum (culture-positive for M tuberculosis) were 100% and 91.2%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in plasma were 34.1% and 29.4%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in pleural effusion were 64.7% and 55.9%, respectively. Experimental analysis of culture supernatant showing that the ICS developed for ESAT-6 had a sensitivity of 100% and a specificity of 91.2%. While the ICS developed for CFP-10 had a sensitivity of 91.2% and a specificity of 88.2%. The validity of the test is limited by source of sample. The technique is sensitive and specific for samples in sputum and culture media but not for plasma or pleural effusion samples. Detection of M tuberculosis using ICSs is rapid, simple, and relatively effective; thus, ICSs are a potential screening tool for TB. PMID:29390519
Wu, Xiaoxin; Wang, Yeping; Weng, Tianhao; Hu, Chenyu; Wang, Frederick X C; Wu, Zhigang; Yu, Dongshan; Lu, Huoquan; Yao, Hangping
2017-12-01
The early secreted protein early secretory antigenic target 6(ESAT-6) and the culture filtrate protein 10 (CFP-10) are 2 antigens that are specific to Mycobacterium tuberculosis. These 2 antigens are good targets for tuberculosis (TB) detection.To rapidly diagnose TB across a variety of samples, we developed colloidal gold immunochromatographic strips (ICSs) based on ESAT-6 and CFP-10.The strips were evaluated using 233 samples, including sputum, plasma, and pleural effusion samples.The positive detection rates for ICSs for ESAT-6 and CFP-10 in sputum (culture-positive for M tuberculosis) were 100% and 91.2%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in plasma were 34.1% and 29.4%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in pleural effusion were 64.7% and 55.9%, respectively. Experimental analysis of culture supernatant showing that the ICS developed for ESAT-6 had a sensitivity of 100% and a specificity of 91.2%. While the ICS developed for CFP-10 had a sensitivity of 91.2% and a specificity of 88.2%.The validity of the test is limited by source of sample. The technique is sensitive and specific for samples in sputum and culture media but not for plasma or pleural effusion samples. Detection of M tuberculosis using ICSs is rapid, simple, and relatively effective; thus, ICSs are a potential screening tool for TB. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Remote Sensing Applications with High Reliability in Changjiang Water Resource Management
NASA Astrophysics Data System (ADS)
Ma, L.; Gao, S.; Yang, A.
2018-04-01
Remote sensing technology has been widely used in many fields. But most of the applications cannot get the information with high reliability and high accuracy in large scale, especially for the applications using automatic interpretation methods. We have designed an application-oriented technology system (PIR) composed of a series of accurate interpretation techniques,which can get over 85 % correctness in Water Resource Management from the view of photogrammetry and expert knowledge. The techniques compose of the spatial positioning techniques from the view of photogrammetry, the feature interpretation techniques from the view of expert knowledge, and the rationality analysis techniques from the view of data mining. Each interpreted polygon is accurate enough to be applied to the accuracy sensitive projects, such as the Three Gorge Project and the South - to - North Water Diversion Project. In this paper, we present several remote sensing applications with high reliability in Changjiang Water Resource Management,including water pollution investigation, illegal construction inspection, and water conservation monitoring, etc.
NASA Astrophysics Data System (ADS)
Gareau, Daniel S.; Karen, Julie K.; Dusza, Stephen W.; Tudisco, Marie; Nehal, Kishwer S.; Rajadhyaksha, Milind
2009-02-01
Mohs surgery, for the precise removal of basal cell carcinomas (BCCs), consists of a series of excisions guided by the surgeon's examination of the frozen histology of the previous excision. The histology reveals atypical nuclear morphology, identifying cancer. The preparation of frozen histology is accurate but labor-intensive and slow. Nuclear pathology can be achieved by staining with acridine orange (1 mM, 20 s) BCCs in Mohs surgical skin excisions within 5-9 minutes, compared to 20-45 for frozen histology. For clinical utility, images must have high contrast and high resolution. We report tumor contrast of 10-100 fold over the background dermis and submicron (diffraction limited) resolution over a cm field of view. BCCs were detected with an overall sensitivity of 96.6%, specificity of 89.2%, positive predictive value of 93.0% and negative predictive value of 94.7%. The technique was therefore accurate for normal tissue as well as tumor. We conclude that fluorescence confocal mosaicing serves as a sensitive and rapid pathological tool. Beyond Mohs surgery, this technology may be extended to suit other pathological needs with the development of new contrast agents. The technique reported here accurately detects all subtypes of BCC in skin excisions, including the large nodular, small micronodular, and tiny sclerodermaform tumors. However, this technique may be applicable to imaging tissue that is larger, more irregular and of various mechanical compliances with further engineering of the tissue mounting and staging mechanisms.
Barda, Beatrice Divina; Rinaldi, Laura; Ianniello, Davide; Zepherine, Henry; Salvo, Fulvio; Sadutshang, Tsetan; Cringoli, Giuseppe; Clementi, Massimo; Albonico, Marco
2013-01-01
Soil-transmitted helminths and intestinal protozoa infection are widespread in developing countries, yet an accurate diagnosis is rarely performed. The aim of this study was to evaluate the recently developed mini-FLOTAC method and to compare with currently more widely used techniques for the diagnosis of intestinal parasitic infections in different settings. The study was carried out in Dharamsala, Himachal Pradesh, India, and in Bukumbi, Tanzania. A total of 180 pupils from two primary schools had their stool analyzed (n = 80 in Dharamsala and n = 100 in Bukumbi) for intestinal parasitic infections with three diagnostic methods: direct fecal smear, formol-ether concentration method (FECM) and mini-FLOTAC. Overall, 72% of the pupils were positive for any intestinal parasitic infection, 24% carried dual infections and 11% three infections or more. The most frequently encountered intestinal parasites were Entamoeba coli, Entamoeba histolytica/dispar, Giardia intestinalis, hookworm, (and Schistosoma mansoni, in Tanzania). Statistically significant differences were found in the detection of parasitic infections among the three methods: mini-FLOTAC was the most sensitive method for helminth infections (90% mini-FLOTAC, 60% FECM, and 30% direct fecal smear), whereas FECM was most sensitive for intestinal protozoa infections (88% FECM, 70% direct fecal smear, and 68% mini-FLOTAC). We present the first experiences with the mini-FLOTAC for the diagnosis of intestinal helminths and protozoa. Our results suggest that it is a valid, sensitive and potentially low-cost alternative technique that could be used in resource-limited settings--particularly for helminth diagnosis.
Detection limits of the strip test and PCR for genetically modified corn in Brazil.
Nascimento, V E; Von Pinho, É V R; Von Pinho, R G; do Nascimento, A D
2012-08-16
Brazilian legislation establishes a labeling limit for products that contain more than 1% material from genetically modified organisms (GMOs). We assessed the sensitivity of the lateral flow strip test in detection of the GMO corn varieties Bt11 and MON810 and the specificity and sensitivity of PCR techniques for their detection. For the strip test, the GMO seeds were mixed with conventional seeds at levels of 0.2, 0.4 and 0.8% for Bt11, and 0.4, 0.8 and 1.6% for MON810. Three different methodologies were assessed and whole seeds, their endosperm and embryonic axis were used. For the PCR technique, the GMO seeds of each of the two varieties were mixed with conventional seeds at levels of 20, 10, 5, 2, 1, and 0.5%. The seeds were ground and the DNA extracted. For detection of the GMO material, specific primers were used for MON810 and Bt11 and maize zein as an endogenous control. The sensitivity of the strip test varied for both maize varieties and methodologies. The test was positive for Bt11 only at 0.8%, in contrast with the detection limit of 0.4% indicated by the manufacturer. In the multiplex PCR, the primers proved to be specific for the different varieties. These varieties were detected in samples with one GMO seed in 100. Thus, this technique proved to be efficient in detecting contaminations equal to or greater than 1%.
Smith, B L; Flores, A; Dechaine, J; Krepela, J; Bergdall, A; Ferrieri, P
2004-05-01
R proteins were first identified by Lancefield in group B Streptococcus (GBS) as resistant to trypsin at pH8 and sensitive to pepsin at pH2. The R4 protein found predominantly in type III and some type II and V invasive isolates conforms to these criteria. The Rib protein, although structurally and epidemiologically similar to R4, was reported as resistant to both proteases. We report here the gene encoding the R4 protein from a type III group B streptococcal isolate (76-043) well characterized in our laboratory. Trypsin extracted GBS proteins were assayed for protease sensitivities by double-diffusion Ouchterlony using varying conditions for the enzyme pepsin. Standard haemoglobin assay was used to examine pepsin enzymatic activity. Thirty clinical isolates of varying protein profiles identified by double-diffusion from our reference strain laboratory were screened by PCR and Southern technique. SDS-PAGE gel purified R4 amino acid sequences were determined and used to design oligonucleotide primers for screening a 76-043 genomic library. R4 was sensitive to pepsin at pH2 but appeared resistant at pH4, the reported pH used for Rib. By standard haemoglobin assay and trypsin extract studies of R4 protein, pepsin was shown to be active at pH2, yet easily inactivated; assays of GBS surface proteins are critical at pH2. Of the amino acids initially sequenced from R4, 88 per cent (61/69) showed identity to Rib; the r4 nucleotide sequence was identical to that of rib. All isolates with strong positive protein reactions for R4 were positive in both PCR and Southern technique, whereas isolates expressing alpha, beta, R1/R4, and R5 (BPS) protein profiles were not. Sequenced PCR products aligned with identity to the R4 and Rib nucleotide sequences and confirmed the identity of these proteins and their molecular sequences.
Multidisciplinary design optimization using multiobjective formulation techniques
NASA Technical Reports Server (NTRS)
Chattopadhyay, Aditi; Pagaldipti, Narayanan S.
1995-01-01
This report addresses the development of a multidisciplinary optimization procedure using an efficient semi-analytical sensitivity analysis technique and multilevel decomposition for the design of aerospace vehicles. A semi-analytical sensitivity analysis procedure is developed for calculating computational grid sensitivities and aerodynamic design sensitivities. Accuracy and efficiency of the sensitivity analysis procedure is established through comparison of the results with those obtained using a finite difference technique. The developed sensitivity analysis technique are then used within a multidisciplinary optimization procedure for designing aerospace vehicles. The optimization problem, with the integration of aerodynamics and structures, is decomposed into two levels. Optimization is performed for improved aerodynamic performance at the first level and improved structural performance at the second level. Aerodynamic analysis is performed by solving the three-dimensional parabolized Navier Stokes equations. A nonlinear programming technique and an approximate analysis procedure are used for optimization. The proceduredeveloped is applied to design the wing of a high speed aircraft. Results obtained show significant improvements in the aircraft aerodynamic and structural performance when compared to a reference or baseline configuration. The use of the semi-analytical sensitivity technique provides significant computational savings.
Survival of gram positive anaerobic cocci on swabs and their isolation from the mouth and vagina.
Smith, G L; Cumming, C G; Ross, P W
1986-01-01
The survival of Gram positive anaerobic cocci on plain cotton wool and albumin coated swabs held in various transport media was investigated. Results suggested that in most cases Amies', Stuart's and VMGII media do not offer any more protection to the bacteria than storing swabs dry in their containers. A technique was developed for the isolation and identification of Gram positive anaerobic cocci from the mouth and vagina, incorporating bicozamycin in the medium as a selective agent. Few strains were recovered from the oral cavity, but larger numbers were isolated from the vagina. Using a minimum number of antibiotic sensitivity and biochemical tests, including analysis of end products by gas-liquid chromatography, most isolates were identified to species level. PMID:3950035
Detection of anticentromere antibodies using cloned autoantigen CENP-B.
Rothfield, N; Whitaker, D; Bordwell, B; Weiner, E; Senecal, J L; Earnshaw, W
1987-12-01
A solid-phase enzyme-linked immunosorbent assay has been established using a cloned fusion protein, CtermCENP-B [beta-gal], as antigen. The fusion protein carries the major epitope of CENP-B, the major centromeric autoantigen. The enzyme-linked immunosorbent assay was more sensitive than immunofluorescence techniques in detecting anticentromere antibodies in patients with scleroderma or Raynaud's disease, and was weakly positive in 3% of normal controls and in 3% of 70 patients with other connective tissue diseases.
Stone, James R; Wilde, Elisabeth A; Taylor, Brian A; Tate, David F; Levin, Harvey; Bigler, Erin D; Scheibel, Randall S; Newsome, Mary R; Mayer, Andrew R; Abildskov, Tracy; Black, Garrett M; Lennon, Michael J; York, Gerald E; Agarwal, Rajan; DeVillasante, Jorge; Ritter, John L; Walker, Peter B; Ahlers, Stephen T; Tustison, Nicholas J
2016-01-01
White matter hyperintensities (WMHs) are foci of abnormal signal intensity in white matter regions seen with magnetic resonance imaging (MRI). WMHs are associated with normal ageing and have shown prognostic value in neurological conditions such as traumatic brain injury (TBI). The impracticality of manually quantifying these lesions limits their clinical utility and motivates the utilization of machine learning techniques for automated segmentation workflows. This study develops a concatenated random forest framework with image features for segmenting WMHs in a TBI cohort. The framework is built upon the Advanced Normalization Tools (ANTs) and ANTsR toolkits. MR (3D FLAIR, T2- and T1-weighted) images from 24 service members and veterans scanned in the Chronic Effects of Neurotrauma Consortium's (CENC) observational study were acquired. Manual annotations were employed for both training and evaluation using a leave-one-out strategy. Performance measures include sensitivity, positive predictive value, [Formula: see text] score and relative volume difference. Final average results were: sensitivity = 0.68 ± 0.38, positive predictive value = 0.51 ± 0.40, [Formula: see text] = 0.52 ± 0.36, relative volume difference = 43 ± 26%. In addition, three lesion size ranges are selected to illustrate the variation in performance with lesion size. Paired with correlative outcome data, supervised learning methods may allow for identification of imaging features predictive of diagnosis and prognosis in individual TBI patients.
Deoxyribonucleic Acid Probes Analyses for the Detection of Periodontal Pathogens.
Al Yahfoufi, Zoubeida; Hadchiti, Wahib; Berberi, Antoine
2015-09-01
In clinical microbiology several techniques have been used to identify bacteria. Recently, Deoxyribonucleic acid (DNA)-based techniques have been introduced to detect human microbial pathogens in periodontal diseases. Deoxyribonucleic acid probes can detect bacteria at a very low level if we compared with the culture methods. These probes have shown rapid and cost-effective microbial diagnosis, good sensitivity and specificity for some periodontal pathogens in cases of severe periodontitis. Eighty-five patients were recruited for the study. Twenty-one subjects ranging between 22 and 48 years of age fulfilled the inclusion and exclusion criteria. Seventy-eight samples became available for DNA probe analysis from the deepest pockets in each quadrant. All 21 patients showed positive results for Prevotella intermedia; also, Prevotella gingivalis was identified in 19 subjects, Aggregatibacter actinomycetemcomitans in 6 subjects. P. intermedia was diagnosed positive in 82% of the subgingival samples taken, 79% for P. gingivalis, and 23% for A. actinomycetemcomitans. This study shows a high frequency of putative periodontal pathogens by using DNA probe technology, which is semi-quantitative in this study. Deoxyribonucleic acid probes can detect bacteria at very low level about 10(3) which is below the detection level of culture methods. The detection threshold of cultural methods. The three types of bacteria can be detected rapidly with high sensitivity by using the DNA probe by general practitioners, and thus can help in the diagnosis process and the treatment.
Digital differential confocal microscopy based on spatial shift transformation.
Liu, J; Wang, Y; Liu, C; Wilson, T; Wang, H; Tan, J
2014-11-01
Differential confocal microscopy is a particularly powerful surface profilometry technique in industrial metrology due to its high axial sensitivity and insensitivity to noise. However, the practical implementation of the technique requires the accurate positioning of point detectors in three-dimensions. We describe a simple alternative based on spatial transformation of a through-focus series of images obtained from a homemade beam scanning confocal microscope. This digital differential confocal microscopy approach is described and compared with the traditional Differential confocal microscopy approach. The ease of use of the digital differential confocal microscopy system is illustrated by performing measurements on a 3D standard specimen. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.
Computer-Aided Diagnostic (CAD) Scheme by Use of Contralateral Subtraction Technique
NASA Astrophysics Data System (ADS)
Nagashima, Hiroyuki; Harakawa, Tetsumi
We developed a computer-aided diagnostic (CAD) scheme for detection of subtle image findings of acute cerebral infarction in brain computed tomography (CT) by using a contralateral subtraction technique. In our computerized scheme, the lateral inclination of image was first corrected automatically by rotating and shifting. The contralateral subtraction image was then derived by subtraction of reversed image from original image. Initial candidates for acute cerebral infarctions were identified using the multiple-thresholding and image filtering techniques. As the 1st step for removing false positive candidates, fourteen image features were extracted in each of the initial candidates. Halfway candidates were detected by applying the rule-based test with these image features. At the 2nd step, five image features were extracted using the overlapping scale with halfway candidates in interest slice and upper/lower slice image. Finally, acute cerebral infarction candidates were detected by applying the rule-based test with five image features. The sensitivity in the detection for 74 training cases was 97.4% with 3.7 false positives per image. The performance of CAD scheme for 44 testing cases had an approximate result to training cases. Our CAD scheme using the contralateral subtraction technique can reveal suspected image findings of acute cerebral infarctions in CT images.
Malla, Javed Ahmed; Chakravarti, Soumendu; Gupta, Vikas; Chander, Vishal; Sharma, Gaurav Kumar; Qureshi, Salauddin; Mishra, Adhiraj; Gupta, Vivek Kumar; Nandi, Sukdeb
2018-02-20
Bovine herpesvirus-1 (BHV-1) is a major viral pathogen affecting bovines leading to various clinical manifestations and causes significant economic impediment in modern livestock production system. Rapid, accurate and sensitive detection of BHV-1 infection at frozen semen stations or at dairy herds remains a priority for control of BHV-1 spread to susceptible population. Polymerase Spiral Reaction (PSR), a novel addition in the gamut of isothermal techniques, has been successfully implemented in initial optimization for detection of BHV-1 genomic DNA and further validated in clinical samples. The developed PSR assay has been validated for detection of BHV-1 from bovine semen (n=99), a major source of transmission of BHV-1 from breeding bulls to susceptible dams in artificial insemination programs. The technique has also been used for screening of BHV-1 DNA from suspected aborted fetal tissues (n=25). The developed PSR technique is 100 fold more sensitive than conventional PCR and comparable to real-time PCR. The PSR technique has been successful in detecting 13 samples positive for BHV-1 DNA in bovine semen, 4 samples more than conventional PCR. The aborted fetal tissues were negative for presence of BHV-1 DNA. The presence of BHV-1 in bovine semen samples raises a pertinent concern for extensively screening of semen from breeding bulls before been used for artificial insemination process. PSR has all the attributes for becoming a method of choice for rapid, accurate and sensitive detection of BHV-1 DNA at frozen semen stations or at dairy herds in resource constrained settings. Copyright © 2017 Elsevier B.V. All rights reserved.
Cessford, Tara; Meneilly, Graydon S; Arishenkoff, Shane; Eddy, Christopher; Chen, Luke Y C; Kim, Daniel J; Ma, Irene W Y
2017-12-08
To determine whether sonographic versions of physical examination techniques can accurately identify splenomegaly, Castell's method (Ann Intern Med 1967; 67:1265-1267), the sonographic Castell's method, spleen tip palpation, and the sonographic spleen tip technique were compared with reference measurements. Two clinicians trained in bedside sonography patients recruited from an urban hematology clinic. Each patient was examined for splenomegaly using conventional percussion and palpation techniques (Castell's method and spleen tip palpation, respectively), as well as the sonographic versions of these maneuvers (sonographic Castell's method and sonographic spleen tip technique). Results were compared with a reference standard based on professional sonographer measurements. The sonographic Castell's method had greater sensitivity (91.7% [95% confidence interval, 61.5% to 99.8%]) than the traditional Castell's method (83.3% [95% confidence interval, 51.6% to 97.9%]) but took longer to perform [mean ± SD, 28.8 ± 18.6 versus 18.8 ± 8.1 seconds; P = .01). Palpable and positive sonographic spleen tip results were both 100% specific, but the sonographic spleen tip method was more sensitive (58.3% [95% confidence interval, 27.7% to 84.8%] versus 33.3% [95% confidence interval, 9.9% to 65.1%]). Sonographic versions of traditional physical examination maneuvers have greater diagnostic accuracy than the physical examination maneuvers from which they are derived but may take longer to perform. We recommend a combination of traditional physical examination and sonographic techniques when evaluating for splenomegaly at the bedside. © 2017 by the American Institute of Ultrasound in Medicine.
NASA Astrophysics Data System (ADS)
Fang, J.
2015-12-01
Marine sediments cover more than two-thirds of the Earth's surface and represent a major part of the deep biosphere. Microbial cells and microbial activity appear to be widespread in these sediments. Recently, we reported the isolation of gram-positive anaerobic spore-forming piezophilic bacteria and detection of bacterial endospores in marine subsurface sediment from the Shimokita coalbed, Japan. However, the modern molecular microbiological methods (e.g., DNA-based microbial detection techniques) cannot detect bacterial endospore, because endospores are impermeable and are not stained by fluorescence DNA dyes or by ribosomal RNA staining techniques such as catalysed reporter deposition fluorescence in situ hybridization. Thus, the total microbial cell abundance in the deep biosphere may has been globally underestimated. This emphasizes the need for a new cultivation independent approach for the quantification of bacterial endospores in the deep subsurface. Dipicolinic acid (DPA, pyridine-2,6-dicarboxylic acid) is a universal and specific component of bacterial endospores, representing 5-15wt% of the dry spore, and therefore is a useful indicator and quantifier of bacterial endospores and permits to estimate total spore numbers in the subsurface biosphere. We developed a sensitive analytical method to quantify DPA content in environmental samples using gas chromatography-mass spectrometry. The method is sensitive and more convenient in use than other traditional methods. We applied this method to analyzing sediment samples from the South China Sea (obtained from IODP Exp. 349) to determine the abundance of spore-forming bacteria in the deep marine subsurface sediment. Our results suggest that gram-positive, endospore-forming bacteria may be the "unseen majority" in the deep biosphere.
Enzymatic signal amplification for sensitive detection of intracellular antigens by flow cytometry.
Karkmann, U; Radbruch, A; Hölzel, V; Scheffold, A
1999-11-19
Flow cytometry is the method of choice for the analysis of single cells with respect to the expression of specific antigens. Antigens can be detected with specific antibodies either on the cell surface or within the cells, after fixation and permeabilization of the cell membrane. Using conventional fluorochrome-labeled antibodies several thousand antigens are required for clear-cut separation of positive and negative cells. More sensitive reagents, e.g., magnetofluorescent liposomes conjugated to specific antibodies permit the detection of less than 200 molecules per cell but cannot be used for the detection of intracellular antigens. Here, we describe an enzymatic amplification technique (intracellular tyramine-based signal amplification, ITSA) for the sensitive cytometric analysis of intracellular cytokines by immunofluorescence. This approach results in a 10 to 15-fold improvement of the signal-to-noise ratio compared to conventional fluorochrome labeled antibodies and permits the detection of as few as 300-400 intracellular antigens per cell.
Shock initiation of 2,4-dinitroimidazole (2,4-DNI)
NASA Astrophysics Data System (ADS)
Urtiew, P. A.; Tarver, C. M.; Simpson, R. L.
1996-05-01
The shock sensitivity of the pressed solid explosive 2,4-dinitroimidazole (2,4-DNI) was determined using the embedded manganin pressure gauge technique. At an initial shock pressure of 2 GPa, several microseconds were required before any exothermic reaction was observed. At 4 GPa, 2,4-DNI reacted more rapidly but did not transition to detonation at the 12 mm deep gauge position. At 6 GPa, detonation occurred in less than 6 mm of shock propagation. Thus, 2,4-DNI is more shock sensitive than TATB-based explosives but is considerably less shock sensitive than HMX-based explosives. An Ignition and Growth reactive flow model for 2,4-DNI based on these gauge records showed that 2,4-DNI exhibits shock initiation characteristics similar to TATB but reacts faster. The chemical structure of 2,4-DNI suggests that it may exhibit thermal decomposition reactions similar to nitroguanine and explosives with similar ring structures, such as ANTA and NTO.
Georgieva, A; Payne, S J; Redman, C W G
2009-12-01
The foetal heart rate (FHR) response to uterine contractions is crucial to detect foetal distress by electronic FHR monitoring during labour. We are developing a new automated system (OxSys) for decision support in labour, using the Oxford database of intrapartum FHR records. We describe here a novel technique for automated detection of uterus contractions. In addition, we present a comparison of the new method with four other computerised approaches. During training, OxSys achieved sensitivity above 95% and positive predictive value (PPV) of up to 90% for traces of good quality. During testing, OxSys achieved sensitivity = 87% and PPV = 75%. For comparison, a second clinical expert obtained sensitivity = 93% and PPV = 80%, and all other computerised approaches achieved lower values. It was concluded that the proposed method can be employed with confidence in our study on foetal health assessment in labour and future OxSys development.
A position- and time-sensitive photon-counting detector with delay- line read-out
NASA Astrophysics Data System (ADS)
Jagutzki, Ottmar; Dangendorf, Volker; Lauck, Ronald; Czasch, Achim; Milnes, James
2007-05-01
We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing rate. Large format detectors of 40 and 75 mm active diameter with internal helical-wire delay-line anodes have been produced and specified. A different type of 40 and 25 mm tubes with semi-conducting screen for image charge read-out allow for an economic and robust tube design and for placing the read-out anodes outside the sealed housing. Two types of external delay-line anodes, i.e. pick-up electrodes for the image charge, have been tested. We present tests of the detector and anode performance. Due to the low background this technique is well suited for applications with very low light intensity and especially if a precise time tagging for each photon is required. As an example we present the application of scintillator read-out in time-of-flight (TOF) neutron radiography. Further applications so far are Fluorescence Life-time Microscopy (FLIM) and Astronomy.
Lauer, B A; Reller, L B; Mirrett, S
1981-01-01
Acridine orange, a fluorochrome strain, is potentially superior to the Gram stain in the direct microscopic examination of clinical specimens because it gives striking differential staining between bacteria and background cells and debris. Its value in clinical laboratories was evaluated by testing 209 cerebrospinal fluids and 288 other body fluids, tissues, and exudates by both techniques. Smears were made in duplicate, fixed with methanol, stained, and examined without knowledge of the result of the companion smear or culture. Overall, acridine orange was slightly more sensitive than the Gram stain (acridine orange, 59.9%; Gram stain, 55.8%) and equally specific in detecting microorganisms. One smear was falsely positive by the Gram stain; none was falsely positive by the acridine orange stain. We conclude that acridine orange staining is a sensitive method for screening clinical specimens and reviewing selected specimens that are purulent, but negative by the Gram stain. Bloody fluids, thick exudates, and other normally difficult-to-read specimens were easily and quickly examined. We recommend, however, that positive smears be reexamined with the Gram stain to confirm the result and determine the Gram reaction of the microorganisms. PMID:6168652
NASA Astrophysics Data System (ADS)
Judson, Richard S.; Rabitz, Herschel
1987-04-01
The relationship between structure in the potential surface and classical mechanical observables is examined by means of functional sensitivity analysis. Functional sensitivities provide maps of the potential surface, highlighting those regions that play the greatest role in determining the behavior of observables. A set of differential equations for the sensitivities of the trajectory components are derived. These are then solved using a Green's function method. It is found that the sensitivities become singular at the trajectory turning points with the singularities going as η-3/2, with η being the distance from the nearest turning point. The sensitivities are zero outside of the energetically and dynamically allowed region of phase space. A second set of equations is derived from which the sensitivities of observables can be directly calculated. An adjoint Green's function technique is employed, providing an efficient method for numerically calculating these quantities. Sensitivity maps are presented for a simple collinear atom-diatom inelastic scattering problem and for two Henon-Heiles type Hamiltonians modeling intramolecular processes. It is found that the positions of the trajectory caustics in the bound state problem determine regions of the highest potential surface sensitivities. In the scattering problem (which is impulsive, so that ``sticky'' collisions did not occur), the positions of the turning points of the individual trajectory components determine the regions of high sensitivity. In both cases, these lines of singularities are superimposed on a rich background structure. Most interesting is the appearance of classical interference effects. The interference features in the sensitivity maps occur most noticeably where two or more lines of turning points cross. The important practical motivation for calculating the sensitivities derives from the fact that the potential is a function, implying that any direct attempt to understand how local potential regions affect the behavior of the observables by repeatedly and systematically altering the potential will be prohibitively expensive. The functional sensitivity method enables one to perform this analysis at a fraction of the computational labor required for the direct method.
Measuring Historical Coastal Change using GIS and the Change Polygon Approach
Smith, M.J.; Cromley, R.G.
2012-01-01
This study compares two automated approaches, the transect-from-baseline technique and a new change polygon method, for quantifying historical coastal change over time. The study shows that the transect-from-baseline technique is complicated by choice of a proper baseline as well as generating transects that intersect with each other rather than with the nearest shoreline. The change polygon method captures the full spatial difference between the positions of the two shorelines and average coastal change is the defined as the ratio of the net area divided by the shoreline length. Although then change polygon method is sensitive to the definition and measurement of shoreline length, the results are more invariant to parameter changes than the transect-from-baseline method, suggesting that the change polygon technique may be a more robust coastal change method. ?? 2012 Blackwell Publishing Ltd.
Maiwald, Bettina; Lobsien, Donald; Kahn, Thomas; Stumpp, Patrick
2014-01-01
Objectives To compare 64-slice contrast-enhanced computed tomography (CT) with 3-Tesla magnetic resonance imaging (MRI) using Gd-EOB-DTPA for the diagnosis of hepatocellular carcinoma (HCC) and evaluate the utility of diffusion-weighted imaging (DWI) in this setting. Methods 3-phase-liver-CT was performed in fifty patients (42 male, 8 female) with suspected or proven HCC. The patients were subjected to a 3-Tesla-MRI-examination with Gd-EOB-DTPA and diffusion weighted imaging (DWI) at b-values of 0, 50 and 400 s/mm2. The apparent diffusion coefficient (ADC)-value was determined for each lesion detected in DWI. The histopathological report after resection or biopsy of a lesion served as the gold standard, and a surrogate of follow-up or complementary imaging techniques in combination with clinical and paraclinical parameters was used in unresected lesions. Diagnostic accuracy, sensitivity, specificity, and positive and negative predictive values were evaluated for each technique. Results MRI detected slightly more lesions that were considered suspicious for HCC per patient compared to CT (2.7 versus 2.3, respectively). ADC-measurements in HCC showed notably heterogeneous values with a median of 1.2±0.5×10−3 mm2/s (range from 0.07±0.1 to 3.0±0.1×10−3 mm2/s). MRI showed similar diagnostic accuracy, sensitivity, and positive and negative predictive values compared to CT (AUC 0.837, sensitivity 92%, PPV 80% and NPV 90% for MRI vs. AUC 0.798, sensitivity 85%, PPV 79% and NPV 82% for CT; not significant). Specificity was 75% for both techniques. Conclusions Our study did not show a statistically significant difference in detection in detection of HCC between MRI and CT. Gd-EOB-DTPA-enhanced MRI tended to detect more lesions per patient compared to contrast-enhanced CT; therefore, we would recommend this modality as the first-choice imaging method for the detection of HCC and therapeutic decisions. However, contrast-enhanced CT was not inferior in our study, so that it can be a useful image modality for follow-up examinations. PMID:25375778
Para-phenylenediamine allergy: current perspectives on diagnosis and management
Mukkanna, Krishna Sumanth; Stone, Natalie M; Ingram, John R
2017-01-01
Para-phenylenediamine (PPD) is the commonest and most well-known component of hair dyes. Oxidative hair dyes and dark henna temporary tattoos contain PPD. Individuals may be sensitized to PPD by temporary henna tattooing in addition to dyeing their hair. PPD allergy can cause severe reactions and may result in complications. In recent years, frequency of positive patch test reactions to PPD has been increasing. Cross-sensitization to other contact allergens may occur, in particular to other hair dye components. Hairdressers are at a high risk for PPD allergy and require counseling regarding techniques to minimize exposure and protective measures while handling hair dye. We focus this review on the current perspectives of diagnosis and management of PPD allergy. PMID:28176912
NASA Astrophysics Data System (ADS)
Hoang, Phong V.; Konyakhin, Igor A.
2017-06-01
Autocollimators are widely used for angular measurements in instrument-making and the manufacture of elements of optical systems (wedges, prisms, plane-parallel plates) to check their shape parameters (rectilinearity, parallelism and planarity) and retrieve their optical parameters (curvature radii, measure and test their flange focusing). Autocollimator efficiency is due to the high sensitivity of the autocollimation method to minor rotations of the reflecting control element or the controlled surface itself. We consider using quaternions to optimize reflector parameters during autocollimation measurements as compared to the matrix technique. Mathematical model studies have demonstrated that the orthogonal positioning of the two basic unchanged directions of the tetrahedral reflector of the autocollimator is optimal by the criterion of reducing measurement errors where the axis of actual rotation is in a bisecting position towards them. Computer results are presented of running quaternion models that yielded conditions for diminishing measurement errors provided apriori information is available on the position of rotation axis. A practical technique is considered for synthesizing the parameters of the tetrahedral reflector that employs the newly-retrieved relationships. Following the relationships found between the angles of the tetrahedral reflector and the angles of the parameters of its initial orientation, an applied technique was developed to synthesize the control element for autocollimation measurements in case apriori information is available on the axis of actual rotation during monitoring measurements of shaft or pipeline deformation.
Comparative evaluation of workload estimation techniques in piloting tasks
NASA Technical Reports Server (NTRS)
Wierwille, W. W.
1983-01-01
Techniques to measure operator workload in a wide range of situations and tasks were examined. The sensitivity and intrusion of a wide variety of workload assessment techniques in simulated piloting tasks were investigated. Four different piloting tasks, psychomotor, perceptual, mediational, and communication aspects of piloting behavior were selected. Techniques to determine relative sensitivity and intrusion were applied. Sensitivity is the relative ability of a workload estimation technique to discriminate statistically significant differences in operator loading. High sensitivity requires discriminable changes in score means as a function of load level and low variation of the scores about the means. Intrusion is an undesirable change in the task for which workload is measured, resulting from the introduction of the workload estimation technique or apparatus.
GPS=A Good Candidate for Data Assimilation?
NASA Technical Reports Server (NTRS)
Poli, P.; Joiner, J.; Kursinski, R.; Einaudi, Franco (Technical Monitor)
2000-01-01
The Global Positioning System (GPS) enables positioning anywhere about our planet. The microwave signals sent by the 24 transmitters are sensitive to the atmosphere. Using the radio occultation technique, it is possible to perform soundings, with a Low Earth Orbiter (700 km) GPS receiver. The insensitiveness to clouds and aerosols, the relatively high vertical resolution (1.5 km), the self-calibration and stability of the GPS make it a priori a potentially good observing system candidate for data assimilation. A low-computing cost simple method to retrieve both temperature and humidity will be presented. Comparisons with radiosonde show the capability of the GPS to resolve the tropopause. Options for using GPS for data assimilation and remaining issues will be discussed.
Le, Nguyen-Quoc-Khanh; Ho, Quang-Thai; Ou, Yu-Yen
2017-09-05
In several years, deep learning is a modern machine learning technique using in a variety of fields with state-of-the-art performance. Therefore, utilization of deep learning to enhance performance is also an important solution for current bioinformatics field. In this study, we try to use deep learning via convolutional neural networks and position specific scoring matrices to identify electron transport proteins, which is an important molecular function in transmembrane proteins. Our deep learning method can approach a precise model for identifying of electron transport proteins with achieved sensitivity of 80.3%, specificity of 94.4%, and accuracy of 92.3%, with MCC of 0.71 for independent dataset. The proposed technique can serve as a powerful tool for identifying electron transport proteins and can help biologists understand the function of the electron transport proteins. Moreover, this study provides a basis for further research that can enrich a field of applying deep learning in bioinformatics. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
[A short form of the positions on nursing diagnosis scale: development and psychometric testing].
Romero-Sánchez, José Manuel; Paloma-Castro, Olga; Paramio-Cuevas, Juan Carlos; Pastor-Montero, Sonia María; O'Ferrall-González, Cristina; Gabaldón-Bravo, Eva Maria; González-Domínguez, Maria Eugenia; Castro-Yuste, Cristina; Frandsen, Anna J; Martínez-Sabater, Antonio
2013-06-01
The Positions on Nursing Diagnosis (PND) is a scale that uses the semantic differential technique to measure nurses' attitudes towards the nursing diagnosis concept. The aim of this study was to develop a shortened form of the Spanish version of this scale and evaluate its psychometric properties and efficiency. A double theoretical-empirical approach was used to obtain a short form of the PND, the PND-7-SV, which would be equivalent to the original. Using a cross-sectional survey design, the reliability (internal consistency and test-retest reliability), construct (exploratory factor analysis, known-groups technique and discriminant validity) and criterion-related validity (concurrent validity), sensitivity to change and efficiency of the PND-7-SV were assessed in a sample of 476 Spanish nursing students. The results endorsed the utility of the PND-7-SV to measure attitudes toward nursing diagnosis in an equivalent manner to the complete form of the scale and in a shorter time.
Combination photo and electron beam lithography with polymethyl methacrylate (PMMA) resist.
Carbaugh, Daniel J; Pandya, Sneha G; Wright, Jason T; Kaya, Savas; Rahman, Faiz
2017-11-10
We describe techniques for performing photolithography and electron beam lithography in succession on the same resist-covered substrate. Larger openings are defined in the resist film through photolithography whereas smaller openings are defined through conventional electron beam lithography. The two processes are carried out one after the other and without an intermediate wet development step. At the conclusion of the two exposures, the resist film is developed once to reveal both large and small openings. Interestingly, these techniques are applicable to both positive and negative tone lithographies with both optical and electron beam exposure. Polymethyl methacrylate, by itself or mixed with a photocatalytic cross-linking agent, is used for this purpose. We demonstrate that such resists are sensitive to both ultraviolet and electron beam irradiation. All four possible combinations, consisting of optical and electron beam lithographies, carried out in positive and negative tone modes have been described. Demonstration grating structures have been shown and process conditions have been described for all four cases.
Molecular identification of Coccidioides spp. in soil samples from Brazil
2011-01-01
Background Since 1991 several outbreaks of acute coccidioidomycosis (CM) were diagnosed in the semi-arid Northeast of Brazil, mainly related to disturbance of armadillo burrows caused by hunters while digging them for the capture of these animals. This activity causes dust contaminated with arthroconidia of Coccidioides posadasii, which, once inhaled, cause the mycosis. We report on the identification of C. posadasii in soil samples related to outbreaks of CM. Results Twenty four soil samples had their DNA extracted and subsequently submitted to a semi-nested PCR technique using specific primers. While only 6 (25%) soil samples were positive for C. posadasii by mice inoculation, all (100%) were positive by the molecular tool. Conclusion This methodology represents a simple, sensitive and specific molecular technique to determine the environmental distribution of Coccidioides spp. in endemic areas, but cannot distinguish the species. Moreover, it may be useful to identify culture isolates. Key-words: 1. Coccidioidomycosis. 2. Coccidioides spp. 3. C. posadasii. 4. Semi-arid. 5. Semi-nested PCR PMID:21575248
Supervised detection of exoplanets in high-contrast imaging sequences
NASA Astrophysics Data System (ADS)
Gomez Gonzalez, C. A.; Absil, O.; Van Droogenbroeck, M.
2018-06-01
Context. Post-processing algorithms play a key role in pushing the detection limits of high-contrast imaging (HCI) instruments. State-of-the-art image processing approaches for HCI enable the production of science-ready images relying on unsupervised learning techniques, such as low-rank approximations, for generating a model point spread function (PSF) and subtracting the residual starlight and speckle noise. Aims: In order to maximize the detection rate of HCI instruments and survey campaigns, advanced algorithms with higher sensitivities to faint companions are needed, especially for the speckle-dominated innermost region of the images. Methods: We propose a reformulation of the exoplanet detection task (for ADI sequences) that builds on well-established machine learning techniques to take HCI post-processing from an unsupervised to a supervised learning context. In this new framework, we present algorithmic solutions using two different discriminative models: SODIRF (random forests) and SODINN (neural networks). We test these algorithms on real ADI datasets from VLT/NACO and VLT/SPHERE HCI instruments. We then assess their performances by injecting fake companions and using receiver operating characteristic analysis. This is done in comparison with state-of-the-art ADI algorithms, such as ADI principal component analysis (ADI-PCA). Results: This study shows the improved sensitivity versus specificity trade-off of the proposed supervised detection approach. At the diffraction limit, SODINN improves the true positive rate by a factor ranging from 2 to 10 (depending on the dataset and angular separation) with respect to ADI-PCA when working at the same false-positive level. Conclusions: The proposed supervised detection framework outperforms state-of-the-art techniques in the task of discriminating planet signal from speckles. In addition, it offers the possibility of re-processing existing HCI databases to maximize their scientific return and potentially improve the demographics of directly imaged exoplanets.
Hwang, J; Kim, S H; Lee, M W; Lee, J Y
2012-07-01
To compare the diagnostic performance of gadoxetic acid-enhanced MRI using 3.0 T with that of multiphasic 64-multirow detector CT (MDCT) for the detection of small (≤2 cm) hepatocellular carcinoma (HCC) in patients with chronic liver disease. A total of 54 patients (44 men, 10 women; age range, 33-81 years) with 59 HCCs (≤2 cm in diameter) who underwent both multiphasic (arterial, portal venous, equilibrium) 64-MDCT and gadoxetic acid-enhanced 3.0 T MRI were enrolled in this study. Two observers independently and randomly reviewed the MR and CT images on a lesion-by-lesion basis. The diagnostic performance of these techniques for the detection of HCC was assessed by alternative free-response receiver operating characteristic (ROC) analysis, in addition to evaluating the sensitivity and positive predictive value. For each observer, the areas under the ROC curve were 0.874 and 0.863 for MRI, respectively, as opposed to 0.660 and 0.687 for CT, respectively. The differences between the two techniques were statistically significant for each observer (p<0.001). The sensitivities (89.8% and 86.4%) of MRI for both observers were significantly higher than those (57.6% and 61.0% for each observer, respectively) of MDCT. No significant difference was seen between the positive predictive values for the two techniques (p>0.05). Gadoxetic acid-enhanced 3.0 T MRI shows a better diagnostic performance than that of 64-MDCT for the detection of small (≤2 cm) HCCs in patients with chronic liver disease.
Rendina, H Jonathon; Gamarel, Kristi E; Pachankis, John E; Ventuneac, Ana; Grov, Christian; Parsons, Jeffrey T
2017-04-01
Minority stress theory represents the most plausible conceptual framework for explaining health disparities for gay and bisexual men (GBM). However, little focus has been given to including the unique stressors experienced by HIV-positive GBM. We explored the role of HIV-related stress within a minority stress model of mental health and condomless anal sex. Longitudinal data were collected on a diverse convenience sample of 138 highly sexually active, HIV-positive GBM in NYC regarding sexual minority (internalized homonegativity and gay-related rejection sensitivity) and HIV-related stressors (internalized HIV stigma and HIV-related rejection sensitivity), emotion dysregulation, mental health (symptoms of depression, anxiety, sexual compulsivity, and hypersexuality), and sexual behavior (condomless anal sex with all male partners and with serodiscordant male partners). Across both sexual minority and HIV-related stressors, internalized stigma was significantly associated with mental health and sexual behavior outcomes while rejection sensitivity was not. Moreover, path analyses revealed that emotion dysregulation mediated the influence of both forms of internalized stigma on symptoms of depression/anxiety and sexual compulsivity/hypersexuality as well as serodiscordant condomless anal sex. We identified two targets of behavioral interventions that may lead to improvements in mental health and reductions in sexual transmission risk behaviors-maladaptive cognitions underlying negative self-schemas and difficulties with emotion regulation. Techniques for cognitive restructuring and emotion regulation may be particularly useful in the development of interventions that are sensitive to the needs of this population while also highlighting the important role that structural interventions can have in preventing these disparities for future generations.
EVALUATION OF THE TEA TREE OIL ACTIVITY TO ANAEROBIC BACTERIA--IN VITRO STUDY.
Ziółkowska-Klinkosz, Marta; Kedzia, Anna; Meissner, Hhenry O; Kedzia, Andrzej W
2016-01-01
The study of the sensitivity to tea tree oil (Australian Company TTD International Pty. Ltd. Sydney) was carried out on 193 strains of anaerobic bacteria isolated from patients with various infections within the oral cavity and respiratory tracts. The susceptibility (MIC) of anaerobes was determined by means of plate dilution technique in Brucella agar supplemented with 5% defibrinated sheep blood, menadione and hemin. Inoculum contained 10(5) CFU per spot was cultured with Steers replicator upon the surface of agar with various tea tree oil concentrations or without oil (anaerobes growth control). Incubation the plates was performed in anaerobic jars under anaerobic conditions at 37 degrees C for 48 h. MIC was defined as the lowest concentrations of the essential oil completely inhibiting growth of anaerobic bacteria. Test results indicate, that among Gram-negative bacteria the most sensitive to essential oil were strains of Veillonella and Porphyromonas species. Essential oil in low concentrations (MIC in the range of = 0.12 - 0.5 mg/mL) inhibited growth of accordingly 80% and 68% strains. The least sensitive were strains of the genus Tannerella, Parabacteroides and Dialister (MIC 1.0 - 2.0 mg/mL). In the case of Gram-positive anaerobic bacteria the tea tree oil was the most active to strains of cocci of the genus Anaerococcus and Ruminococcus (MIC in range = 0.12 - 0.5 mg/mL) or strains of rods of the genus Eubacterium and Eggerthella (MIC = 0.25 mg/mL). Among Gram-positive rods the least sensitive were the strains of the genus Bifidobacterium ( MIC = 2.0 mg/mL). The tea tree oil was more active to Gram-positive than to Gram-negative anaerobic bacteria.
Rendina, H. Jonathon; Gamarel, Kristi E.; Pachankis, John E.; Ventuneac, Ana; Grov, Christian; Parsons, Jeffrey T.
2016-01-01
Background Minority stress theory represents the most plausible conceptual framework for explaining health disparities for gay and bisexual men (GBM). However, little focus has been given to including the unique stressors experienced by HIV-positive GBM. Purpose We explored the role of HIV-related stress within a minority stress model of mental health and condomless anal sex. Methods Longitudinal data were collected on a diverse convenience sample of 138 highly sexually active, HIV-positive GBM in NYC regarding sexual minority (internalized homonegativity, gay-related rejection sensitivity) and HIV-related stressors (internalized HIV stigma, HIV-related rejection sensitivity), emotion dysregulation, mental health (symptoms of depression, anxiety, sexual compulsivity, and hypersexuality), and sexual behavior (condomless anal sex with all male partners and with serodiscordant male partners). Results Across both sexual minority and HIV-related stressors, internalized stigma was significantly associated with mental health and sexual behavior outcomes while rejection sensitivity was not. Moreover, path analyses revealed that emotion dysregulation mediated the influence of both forms of internalized stigma on symptoms of depression/anxiety and sexual compulsivity/hypersexuality as well as serodiscordant condomless anal sex. Conclusions We identified two targets of behavioral interventions that may lead to improvements in mental health and reductions in sexual transmission risk behaviors—maladaptive cognitions underlying negative self-schemas and difficulties with emotion regulation. Techniques for cognitive restructuring and emotion regulation may be particularly useful in the development of interventions that are sensitive to the needs of this population while also highlighting the important role that structural interventions can have in preventing these disparities for future generations. PMID:27502073
How I report breast magnetic resonance imaging studies for breast cancer staging and screening.
Vinnicombe, Sarah
2016-07-25
Magnetic resonance imaging (MRI) of the breast is the most sensitive imaging technique for the diagnosis and local staging of primary breast cancer and yet, despite the fact that it has been in use for 20 years, there is little evidence that its widespread uncritical adoption has had a positive impact on patient-related outcomes.This has been attributed previously to the low specificity that might be expected with such a sensitive modality, but with modern techniques and protocols, the specificity and positive predictive value for malignancy can exceed that of breast ultrasound and mammography. A more likely explanation is that historically, clinicians have acted on MRI findings and altered surgical plans without prior histological confirmation. Furthermore, modern adjuvant therapy for breast cancer has improved so much that it has become a very tall order to show a an improvement in outcomes such as local recurrence rates.In order to obtain clinically useful information, it is necessary to understand the strengths and weaknesses of the technique and the physiological processes reflected in breast MRI. An appropriate indication for the scan, proper patient preparation and good scan technique, with rigorous quality assurance, are all essential prerequisites for a diagnostically relevant study.The use of recognised descriptors from a standardised lexicon is helpful, since assessment can then dictate subsequent recommendations for management, as in the American College of Radiology BI-RADS (Breast Imaging Reporting and Data System) lexicon (Morris et al., ACR BI-RADS® Atlas, Breast Imaging Reporting and Data System, 2013). It also enables audit of the service. However, perhaps the most critical factor in the generation of a meaningful report is for the reporting radiologist to have a thorough understanding of the clinical question and of the findings that will influence management. This has never been more important than at present, when we are in the throes of a remarkable paradigm shift in the treatment of both early stage and locally advanced breast cancer.
Conductivity tomography based on pulsed eddy current with SQUID magnetometer
NASA Astrophysics Data System (ADS)
Panaitov, G. I.; Krause, H.-J.; Zhang, Y.
2002-05-01
Pulsed eddy current (EC) techniques have the advantage of potentially covering a broader depth range than standard single frequency EC testing. We developed a novel pulsed EC technique using a liquid-nitrogen cooled SQUID magnetometer. For two reasons, SQUID magnetometers are particularly well suited as sensors: first they constitute an extremely sensitive magnetic field sensor, second they measure the field directly which decays more slowly than its time derivative picked up by induction coils. A square waveform transmitter signal was used, with alternating slopes in order to eliminate drift effect, and stacking synchronous to the power line frequency in order to improve signal-to-noise. The early time (high frequency) data of the recorded transient correspond to the upper layers of the conducting medium, while late time data or low frequencies deliver information on deep layers. Measurements of cracks at different depths in a stacked aluminum sample are presented. From the measured data, the apparent conductivity of the sample was calculated for each position and depth by applying a technique known from geophysical data interpretation. Thus, the position and depth of the crack was determined from the tomographic conductivity image of the sample.
Mishra, Apurva; Pandey, Ramesh K; Manickam, Natesan
2015-01-01
Rapid phylogenetic and functional gene (gtfB) identification of S. mutans from the dental plaque derived from children. Dental plaque collected from fifteen patients of age group 7-12 underwent centrifugation followed by genomic DNA extraction for S. mutans. Genomic DNA was processed with S. mutans specific primers in suitable PCR condtions for phylogenetic and functional gene (gtfB) identification. The yield and results were confirmed by agarose gel electrophoresis. 1% agarose gel electrophoresis depicts the positive PCR amplification at 1,485 bp when compared with standard 1 kbp indicating the presence of S. mutans in the test sample. Another PCR reaction was set using gtfB primers specific for S. mutans for functional gene identification. 1.2% agarose gel electrophoresis was done and a positive amplication was observed at 192 bp when compared to 100 bp standards. With the advancement in molecular biology techniques, PCR based identification and quantification of the bacterial load can be done within hours using species-specific primers and DNA probes. Thus, this technique may reduce the laboratory time spend in conventional culture methods, reduces the possibility of colony identification errors and is more sensitive to culture techniques.
Easy detection of multiple Alexandrium species using DNA chromatography chip.
Nagai, Satoshi; Miyamoto, Shigehiko; Ino, Keita; Tajimi, Seisuke; Nishi, Hiromi; Tomono, Jun
2016-01-01
In this study, the Kaneka DNA chromatography chip (KDCC) for the Alexandrium species was successfully developed for simultaneous detection of five Alexandrium species. This method utilizes a DNA-DNA hybridization technology. In the PCR process, specifically designed tagged-primers are used, i.e. a forward primer consisting of a tag domain, which can conjugate with gold nanocolloids on the chip, and a primer domain, which can anneal/amplify the target sequence. However, the reverse primer consists of a tag domain, which can hybridize to the solid-phased capture probe on the chip, and a primer domain, which can anneal/amplify the target sequence. As a result, a red line that originates from gold nanocolloids appears as a positive signal on the chip, and the amplicon is detected visually by the naked eye. This technique is simple, because it is possible to visually detect the target species soon after (<5min) the application of 2μL of PCR amplicon and 65μL of development buffer to the sample pad of the chip. Further, this technique is relatively inexpensive and does not require expensive laboratory equipment, such as real-time Q-PCR machines or DNA microarray detectors, but a thermal cycler. Regarding the detection limit of KDCC for the five Alexandrium species, it varied among species and it was <0.1-10pg and equivalent to 5-500 copies of rRNA genes, indicating that the technique is sensitive enough for practical use to detect several cells of the target species from 1L of seawater. The detection sensitivity of KDCC was also evaluated with two different techniques, i.e. a multiplex-PCR and a digital DNA hybridization by digital DNA chip analyzer (DDCA), using natural plankton assemblages. There was no significant difference in the detection sensitivity among the three techniques, suggesting KDCC can be readily used to monitor the HAB species. Copyright © 2015 Elsevier B.V. All rights reserved.
Application of a sensitivity analysis technique to high-order digital flight control systems
NASA Technical Reports Server (NTRS)
Paduano, James D.; Downing, David R.
1987-01-01
A sensitivity analysis technique for multiloop flight control systems is studied. This technique uses the scaled singular values of the return difference matrix as a measure of the relative stability of a control system. It then uses the gradients of these singular values with respect to system and controller parameters to judge sensitivity. The sensitivity analysis technique is first reviewed; then it is extended to include digital systems, through the derivation of singular-value gradient equations. Gradients with respect to parameters which do not appear explicitly as control-system matrix elements are also derived, so that high-order systems can be studied. A complete review of the integrated technique is given by way of a simple example: the inverted pendulum problem. The technique is then demonstrated on the X-29 control laws. Results show linear models of real systems can be analyzed by this sensitivity technique, if it is applied with care. A computer program called SVA was written to accomplish the singular-value sensitivity analysis techniques. Thus computational methods and considerations form an integral part of many of the discussions. A user's guide to the program is included. The SVA is a fully public domain program, running on the NASA/Dryden Elxsi computer.
Khan, Mehran; Li, Benjin; Jiang, Yue; Weng, Qiyong; Chen, Qinghe
2017-01-01
Late blight, caused by the oomycete Phytophthora infestans, is one of the most devastating diseases affecting potato and tomato worldwide. Early diagnosis of the P. infestans pathogen causing late blight should be the top priority for addressing disease epidemics and management. In this study, we performed a loop-mediated isothermal amplification (LAMP) assay, conventional polymerase chain reaction (PCR), nested PCR, and real-time PCR to verify and compare the sensitivity and specificity of the reaction based on the Ypt1 (Ras-related protein) gene of P. infestans. In comparison with the PCR-based assays, the LAMP technique led to higher specificity and sensitivity, using uncomplicated equipment with an equivalent time frame. All 43 P. infestans isolates, yielded positive detection results using LAMP assay showing no cross reaction with other Phytophthora spp., oomycetes or fungal pathogens. The LAMP assay yielded the lowest detectable DNA concentration (1.28 × 10-4 ng μL-1), being 10 times more sensitive than nested PCR (1.28 × 10-3 ng μL-1), 100 times more sensitive than real-time PCR (1.28 × 10-2 ng μL-1) and 103 times more sensitive than the conventional PCR assay (1.28 × 10-1 ng μL-1). In the field experiment, the LAMP assay outperformed the other tests by amplifying only diseased tissues (leaf and stem), and showing no positive reaction in healthy tissues. Overall, the LAMP assay developed in this study provides a specific, sensitive, simple, and effective visual method for detection of the P. infestans pathogen, and is therefore suitable for application in early prediction of the disease to reduce the risk of epidemics. PMID:29051751
Khan, Mehran; Li, Benjin; Jiang, Yue; Weng, Qiyong; Chen, Qinghe
2017-01-01
Late blight, caused by the oomycete Phytophthora infestans , is one of the most devastating diseases affecting potato and tomato worldwide. Early diagnosis of the P. infestans pathogen causing late blight should be the top priority for addressing disease epidemics and management. In this study, we performed a loop-mediated isothermal amplification (LAMP) assay, conventional polymerase chain reaction (PCR), nested PCR, and real-time PCR to verify and compare the sensitivity and specificity of the reaction based on the Ypt1 (Ras-related protein) gene of P. infestans. In comparison with the PCR-based assays, the LAMP technique led to higher specificity and sensitivity, using uncomplicated equipment with an equivalent time frame. All 43 P. infestans isolates, yielded positive detection results using LAMP assay showing no cross reaction with other Phytophthora spp., oomycetes or fungal pathogens. The LAMP assay yielded the lowest detectable DNA concentration (1.28 × 10 -4 ng μL -1 ), being 10 times more sensitive than nested PCR (1.28 × 10 -3 ng μL -1 ), 100 times more sensitive than real-time PCR (1.28 × 10 -2 ng μL -1 ) and 10 3 times more sensitive than the conventional PCR assay (1.28 × 10 -1 ng μL -1 ). In the field experiment, the LAMP assay outperformed the other tests by amplifying only diseased tissues (leaf and stem), and showing no positive reaction in healthy tissues. Overall, the LAMP assay developed in this study provides a specific, sensitive, simple, and effective visual method for detection of the P. infestans pathogen, and is therefore suitable for application in early prediction of the disease to reduce the risk of epidemics.
Randall, David; Joosten, Frank; ten Broek, Richard; Gillott, Richard; Bardhan, Karna Dev; Strik, Chema; Prins, Wiesje; van Goor, Harry; Fenner, John
2017-07-14
A non-invasive diagnostic technique for abdominal adhesions is not currently available. Capture of abdominal motion due to respiration in cine-MRI has shown promise, but is difficult to interpret. This article explores the value of a complimentary diagnostic aid to facilitate the non-invasive detection of abdominal adhesions using cine-MRI. An image processing technique was developed to quantify the amount of sliding that occurs between the organs of the abdomen and the abdominal wall in sagittal cine-MRI slices. The technique produces a 'sheargram' which depicts the amount of sliding which has occurred over 1-3 respiratory cycles. A retrospective cohort of 52 patients, scanned for suspected adhesions, made 281 cine-MRI sagittal slices available for processing. The resulting sheargrams were reported by two operators and compared to expert clinical judgement of the cine-MRI scans. The sheargram matched clinical judgement in 84% of all sagittal slices and 93-96% of positive adhesions were identified on the sheargram. The sheargram displayed a slight skew towards sensitivity over specificity, with a high positive adhesion detection rate but at the expense of false positives. Good correlation between sheargram and absence/presence of inferred adhesions indicates quantification of sliding motion has potential to aid adhesion detection in cine-MRI. Advances in Knowledge: This is the first attempt to clinically evaluate a novel image processing technique quantifying the sliding motion of the abdominal contents against the abdominal wall. The results of this pilot study reveal its potential as a diagnostic aid for detection of abdominal adhesions.
de Almeida, Isabela Neves; Aleixo, Agdemir Valéria; Carvalho, Wânia da Silva; de Miranda, Silvana Spindola
2015-01-01
The possibility to obtain DNA from smears is a valuable alternative to remedy the lack of samples when they are totally used for bacilloscopy; this technique solves the biosafety problem related to a possible accident with the transportation of flasks containing potentially transmissible clinical samples. Hence, the purpose of this study was to utilize the insertion sequence IS6110 for amplification of DNA from a smear-positive sample for tuberculosis (TB) diagnosis. Among the 52 positive bacilloscopies, sensitivity, specificity, positive predictive value and negative predictive value were 52.3%, 100%, 100% and 89.7%, respectively whereas accuracy was 90.7%. The IS6110-based PCR for TB diagnosis developed in DNA extracted from a positive smear is a fast, simple, specific, and safe method. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.
NASA Technical Reports Server (NTRS)
Ishikawa, Shin-nosuke; Katsuragawa, Miho; Watanabe, Shin; Uchida, Yuusuke; Takeda, Shin'lchiro; Takahashi, Tadayuki; Saito, Shinya; Glesener, Lindsay; Bultrago-Casas, Juan Camilo; Krucker, Sam;
2016-01-01
We have developed a fine-pitch hard X-ray (HXR) detector using a cadmium telluride (CdTe) semiconductor for imaging and spectroscopy for the second launch of the Focusing Optics Solar X-ray Imager (FOXSI). FOXSI is a rocket experiment to perform high sensitivity HXR observations from 4 to 15 keV using the new technique of HXR focusing optics. The focal plane detector requires less than 100 micrometers position resolution (to take advantage of the angular resolution of the optics) and approximately equals 1 keV energy resolution (full width at half maximum (FWHM)) for spectroscopy down to 4 keV, with moderate cooling (greater than -30 C). Double-sided silicon strip detectors were used for the first FOXSI flight in 2012 to meet these criteria. To improve the detectors' efficiency (66% at 15 keV for the silicon detectors) and position resolution of 75 micrometers for the second launch, we fabricated double-sided CdTe strip detectors with a position resolution of 60 micrometers and almost 100% efficiency for the FOXSI energy range. The sensitive area is 7.67 mm x 7.67 mm, corresponding to the field of view of 791'' x 791''. An energy resolution of 1 keV (FWHM) and low-energy threshold of approximately equals 4 keV were achieved in laboratory calibrations. The second launch of FOXSI was performed on 11 December 2014, and images from the Sun were successfully obtained with the CdTe detector. Therefore, we successfully demonstrated the detector concept and the usefulness of this technique for future HXR observations of the Sun.
Espirito-Santo, M C C; Sanchez, M C A; Sanchez, A R; Alvarado-Mora, M V; Castilho, V L P; Gonçalves, E M N; Luna, E J A; Gryschek, R C B
2014-12-01
Schistosomiasis is a major public health concern, with 200 million people infected worldwide. In Brazil, this disease has been reported in 19 states, and its prevalence in the city of Barra Mansa in Rio de Janeiro State is 1 %. The parasitological diagnostic methods currently available in these areas lack sensitivity; however, enzyme-linked immunosorbent assays (ELISAs) have been employed successfully for the diagnosis of schistosomiasis by using antibodies against antigens of Schistosoma mansoni adult worms and eggs, and for the detection of circulating antigens. The objective of this study was to determine systematically the prevalence of S. mansoni infection in the peripheral areas of Barra Mansa. A cross-sectional study was conducted from April to December 2011 by using probabilistic sampling that collected 610 fecal samples and 612 serum samples. ELISA-IgG with total extracts and ELISA-IgM with trichloroacetic acid-soluble fractions were employed to detect antibodies against S. mansoni and were compared with the Kato-Katz and Hoffman parasitological techniques. Among the individuals studied, anti-S. mansoni antibodies were detected in 11.16 % (n = 71) by ELISA-IgG and in 20.75 % (n = 132) by ELISA-IgM, while the parasitological techniques showed 0.82 % (n = 5) positivity. The agreement between the two ELISA tests was 85.38 % (n = 543), and 8.65 % (n = 55) of the serum samples showed positive results in both tests. The higher positivity of the ELISA-IgM test corroborates the results of previous reports and indicates that the test may be a useful tool in epidemiological studies, particularly in areas of low endemicity for S. mansoni.
NASA Astrophysics Data System (ADS)
Ishikawa, Shin-nosuke; Katsuragawa, Miho; Watanabe, Shin; Uchida, Yuusuke; Takeda, Shin'ichiro; Takahashi, Tadayuki; Saito, Shinya; Glesener, Lindsay; Buitrago-Casas, Juan Camilo; Krucker, Säm.; Christe, Steven
2016-07-01
We have developed a fine-pitch hard X-ray (HXR) detector using a cadmium telluride (CdTe) semiconductor for imaging and spectroscopy for the second launch of the Focusing Optics Solar X-ray Imager (FOXSI). FOXSI is a rocket experiment to perform high sensitivity HXR observations from 4 to 15 keV using the new technique of HXR focusing optics. The focal plane detector requires <100μm position resolution (to take advantage of the angular resolution of the optics) and ≈1 keV energy resolution (full width at half maximum (FWHM)) for spectroscopy down to 4 keV, with moderate cooling (>-30°C). Double-sided silicon strip detectors were used for the first FOXSI flight in 2012 to meet these criteria. To improve the detectors' efficiency (66% at 15 keV for the silicon detectors) and position resolution of 75 μm for the second launch, we fabricated double-sided CdTe strip detectors with a position resolution of 60 μm and almost 100% efficiency for the FOXSI energy range. The sensitive area is 7.67 mm × 7.67 mm, corresponding to the field of view of 791'' × 791''. An energy resolution of 1 keV (FWHM) and low-energy threshold of ≈4 keV were achieved in laboratory calibrations. The second launch of FOXSI was performed on 11 December 2014, and images from the Sun were successfully obtained with the CdTe detector. Therefore, we successfully demonstrated the detector concept and the usefulness of this technique for future HXR observations of the Sun.
A Vibrating Wire System For Quadrupole Fiducialization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wolf, Zachary
2010-12-13
A vibrating wire system is being developed to fiducialize the quadrupoles between undulator segments in the LCLS. This note provides a detailed analysis of the system. The LCLS will have quadrupoles between the undulator segments to keep the electron beam focused. If the quadrupoles are not centered on the beam axis, the beam will receive transverse kicks, causing it to deviate from the undulator axis. Beam based alignment will be used to move the quadrupoles onto a straight line, but an initial, conventional alignment must place the quadrupole centers on a straight line to 100 {micro}m. In the fiducialization stepmore » of the initial alignment, the position of the center of the quadrupole is measured relative to tooling balls on the outside of the quadrupole. The alignment crews then use the tooling balls to place the magnet in the tunnel. The required error on the location of the quadrupole center relative to the tooling balls must be less than 25 {micro}m. In this note, we analyze a system under construction for the quadrupole fiducialization. The system uses the vibrating wire technique to position a wire onto the quadrupole magnetic axis. The wire position is then related to tooling balls using wire position detectors. The tooling balls on the wire position detectors are finally related to tooling balls on the quadrupole to perform the fiducialization. The total 25 {micro}m fiducialization error must be divided between these three steps. The wire must be positioned onto the quadrupole magnetic axis to within 10 {micro}m, the wire position must be measured relative to tooling balls on the wire position detectors to within 15 {micro}m, and tooling balls on the wire position detectors must be related to tooling balls on the quadrupole to within 10 {micro}m. The techniques used in these three steps will be discussed. The note begins by discussing various quadrupole fiducialization techniques used in the past and discusses why the vibrating wire technique is our method of choice. We then give an overview of the measurement system showing how the vibrating wire is positioned onto the quadrupole axis, how the wire position detectors locate the wire relative to tooling balls without touching the wire, and how the tooling ball positions are all measured. The novel feature of this system is the vibrating wire which we discuss in depth. We analyze the wire dynamics and calculate the expected sensitivity of the system. The note should be an aid in debugging the system by providing calculations to compare measurements to.« less
Evaluation of a new rapid diagnostic test for the detection of influenza and RSV.
Gómez, Sara; Prieto, Columbiana; Vera, Carmen; R Otero, Joaquín; Folgueira, Lola
2016-05-01
Influenza viruses and respiratory syncytial virus (RSV) can cause an acute respiratory disease that occurs seasonally in epidemic waves. This retrospective study was conducted to evaluate the Sofia(®) Influenza A+B and the Sofia(®) RSV fluorescence immunoassays (FIAs), two novel rapid detection tests (RDTs) for influenza A and B and RSV. Two hundred and nine breath samples were selected from patients with respiratory symptoms determined to be positive/negative for influenza A, influenza B or RSV using one of the reference diagnostic techniques, cell culture and/or RT-PCR (Simplexa™Flu A/B & RSV). The Sofia Influenza A+B FIA was tested on 123 samples (63 from children and 60 from adults) and the Sofia RSV FIA was tested on 86 pediatric samples. Sensitivity and specificity values of both assays were calculated assuming the reference techniques as the gold standard. Sensitivity and specificity values for the Sofia Influenza A+B FIA were 73.1% and 97.8%, respectively. Sensitivity and specificity values for the Sofia RSV FIA were 87.5% and 86.7%, respectively. The sensitivity results obtained for the two assays were considerably higher than those reported for other RDTs. In conclusion, the Sofia Influenza A+B and the Sofia RSV FIAs are appropriate tools for the rapid diagnosis of these viruses. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
Del Cura, Jose Luis; Coronado, Gloria; Zabala, Rosa; Korta, Igone; López, Ignacio
2018-01-31
To review the diagnostic accuracy of ultrasound-guided core-needle biopsy (CNB) in the diagnosis of salivary gland tumours (SGT). Retrospective, institutional review board approved, analysis of the CNB of SGT performed at our centre in 8 years. We used an automatic 18-G spring-loaded device. The final diagnosis was based on surgery in the cases that were operated on, and on clinical evolution and biopsy findings in the rest. Four hundred and nine biopsies were performed in 381 patients (ages, 2-97 years; mean, 55.9). There were two minor complications. Biopsy was diagnostic in 98.3%. There were eight false negatives. The diagnostic values for malignancy were: sensitivity 89.6%, specificity 100%, positive predictive value (PPV) 100% and negative predictive value (NPV) 98%. For the detection of neoplasms were: sensitivity 98.7%, specificity 99%, PPV 99.7% and VPN 96.1%. Accuracy of CNB in SGT is very high, with a very high sensitivity and an absolutely reliable diagnosis of malignancy. Complication rate is very low. It should be considered the technique of choice when a STG is detected. Normal tissue results warrant repeating biopsy. • Ultrasound-guided core-biopsy is the technique of choice in salivary glands nodules • Sensitivity, specificity for detecting neoplasms (which should be resected) are around 99% • Diagnosis of malignancy in core-biopsy is absolutely reliable • A CNB result of "normal tissue", however, warrants repeating the biopsy • Complication rate is very low.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yao, Juan; Zhou, Yufan; Sui, Xiao
Switchable ionic liquids (SWIL) play an important role in green chemistry. Due to the nature of SWIL chemistry, such as air sensitivity and pressure and temperature dependence, it is difficult to characterize SWIL using vacuum-based surface techniques. The fully CO2 loaded and none-loaded DBU and hexanol mixtures, a SWIL system, were analyzed in situ by time-of-flight secondary ion mass spectrometry (ToF-SIMS) coupled with the System for Analysis at the Liquid Vacuum Interface (SALVI), respectively. The DBU/Hexanol/CO2 SWIL was injected into the microchannel before liquid SIMS analysis. Bi3+ primary ion beam was used. The positive and negative spectra of the SWILmore » chemical components are presented. The characteristic peaks m/z 153 (reduced DBU) in the positive mode and m/z 101 (oxidized hexanol) in negative mode were observed. In addition, ion pair peaks including m/z 253, 319, 305, 451 in the positive mode and m/z 145, 223, 257 in the negative mode are first observed using this approach. These results demonstrate that the SALVI microfluidic reactor enables the vacuum-based surface technique (i.e., ToF-SIMS) for in situ characterization of challenging liquid samples such as ionic liquids.« less
Fricker-Hidalgo, H; Pelloux, H; Muet, F; Racinet, C; Bost, M; Goullier-Fleuret, A; Ambroise-Thomas, P
1997-09-01
The prenatal diagnosis of congenital toxoplasmosis is mainly based on biological tests performed on fetal blood and amniotic fluid. We studied the performance of neonatal diagnosis procedures and the results of fetal blood and amniotic fluid analysis. Of 127 women who contracted toxoplasmosis and underwent prenatal diagnosis, the postnatal serological follow-up was long enough to definitively diagnose congenital toxoplasmosis in 19 cases and to exclude it in 27 cases. Prenatal diagnosis allowed the detection of 94.7 per cent (18/19) of the infected fetuses. The sensitivities of tests in amniotic fluid and fetal blood were equivalent, 88.2 per cent (15/17) and 87.5 per cent (14/16), respectively. In fetal blood, biological techniques were positive in 12/16 cases and in 2/16 cases, serological tests were the only positive sign. The specificities of tests in amniotic fluid and fetal blood were respectively 100 per cent (23/23) and 86.3 per cent (19/22) (three false-positive serological results). These results, added to the lower morbidity of amniocentesis compared with cordocentesis, might lead to cordocentesis being abandoned in the prenatal diagnosis of congenital toxoplasmosis.
Xu, Yan; Liu, Biao; Ding, Fengan; Zhou, Xiaodie; Tu, Pin; Yu, Bo; He, Yan; Huang, Peilin
2017-06-01
Circulating tumor cells (CTCs), isolated as a 'liquid biopsy', may provide important diagnostic and prognostic information. Therefore, rapid, reliable and unbiased detection of CTCs are required for routine clinical analyses. It was demonstrated that negative enrichment, an epithelial marker-independent technique for isolating CTCs, exhibits a better efficiency in the detection of CTCs compared with positive enrichment techniques that only use specific anti-epithelial cell adhesion molecules. However, negative enrichment techniques incur significant cell loss during the isolation procedure, and as it is a method that uses only one type of antibody, it is inherently biased. The detection procedure and identification of cell types also relies on skilled and experienced technicians. In the present study, the detection sensitivity of using negative enrichment and a previously described unbiased detection method was compared. The results revealed that unbiased detection methods may efficiently detect >90% of cancer cells in blood samples containing CTCs. By contrast, only 40-60% of CTCs were detected by negative enrichment. Additionally, CTCs were identified in >65% of patients with stage I/II lung cancer. This simple yet efficient approach may achieve a high level of sensitivity. It demonstrates a potential for the large-scale clinical implementation of CTC-based diagnostic and prognostic strategies.
Slomka, Marek J; To, Thanh L; Tong, Hien H; Coward, Vivien J; Mawhinney, Ian C; Banks, Jill; Brown, Ian H
2012-09-01
Evaluation of two commercial lateral flow devices (LFDs) for avian influenza (AI) detection in H5N1 highly pathogenic AI infected poultry in Vietnam. Determine sensitivity and specificity of the LFDs relative to a validated highly sensitive H5 RRT PCR. Swabs (cloacal and tracheal) and feathers were collected from 46 chickens and 48 ducks (282 clinical specimens) and tested by both LFDs and H5 RRT PCR. A subset of 59 chicken and 34 duck specimens was also tested by virus isolation (VI), the 'gold standard'. Twenty-six chickens and 15 ducks were shown to be infected by at least one RRT PCR positive clinical specimen per bird. Bird-level sensitivity for the Anigen LFD was 84·6% for chickens and 53·3% for ducks, and for the Quickvue LFD 65·4% for chickens and 33·3% for ducks. Comparison of the three clinical specimens revealed that chicken feathers were the most sensitive with 84% and 56% sensitivities for Anigen and Quickvue respectively. All 21 RRT PCR positive swabs from ducks were negative by both LFDs. However, duck feather testing gave sensitivities of 53·3% and 33·3% for Anigen and Quickvue respectively. Specificity was 100% for both LFDs in all investigations. Although LFDs were less sensitive than AI RRT PCR and VI, high titre viral shedding in H5N1 highly pathogenic avian influenza (HPAI) infected and diseased chickens is sufficient for a proportion of birds to be identified as AI infected by LFDs. Feathers were the optimal specimen for LFD testing in such diseased HPAI scenarios, particularly for ducks where swab testing by LFDs failed to identify any infected birds. However, specimens should be forwarded to the laboratory for confirmation by more sensitive diagnostic techniques. © 2011 Blackwell Publishing Ltd.
Kimmel, Daniel L.; Mammo, Dagem; Newsome, William T.
2012-01-01
From human perception to primate neurophysiology, monitoring eye position is critical to the study of vision, attention, oculomotor control, and behavior. Two principal techniques for the precise measurement of eye position—the long-standing sclera-embedded search coil and more recent optical tracking techniques—are in use in various laboratories, but no published study compares the performance of the two methods simultaneously in the same primates. Here we compare two popular systems—a sclera-embedded search coil from C-N-C Engineering and the EyeLink 1000 optical system from SR Research—by recording simultaneously from the same eye in the macaque monkey while the animal performed a simple oculomotor task. We found broad agreement between the two systems, particularly in positional accuracy during fixation, measurement of saccade amplitude, detection of fixational saccades, and sensitivity to subtle changes in eye position from trial to trial. Nonetheless, certain discrepancies persist, particularly elevated saccade peak velocities, post-saccadic ringing, influence of luminance change on reported position, and greater sample-to-sample variation in the optical system. Our study shows that optical performance now rivals that of the search coil, rendering optical systems appropriate for many if not most applications. This finding is consequential, especially for animal subjects, because the optical systems do not require invasive surgery for implantation and repair of search coils around the eye. Our data also allow laboratories using the optical system in human subjects to assess the strengths and limitations of the technique for their own applications. PMID:22912608
Role of imprint cytology in intra operative diagnosis of thyroid lesions.
Anila, K R; Krishna, G
2014-07-01
Intra-operative imprint cytology is an important diagnostic modality in the diagnosis of thyroid lesions. A correct intra-operative diagnosis helps eliminate the need for second surgery. To study diagnostic accuracy of imprint cytology and to compare the imprint cytology results with that of the corresponding paraffin section diagnosis in thyroidectomy cases. This is a prospective study of 84 patients who have undergone thyroidectomies over a period of one year at the Department of Surgery, Thiruvananthapuram, Kerala, India. The intraoperative imprint cytology smears were stained by Papanicolaou method. The imprint cytology interpretation was later compared with the paraffin section diagnosis. Of the 84 patients using haematoxylin and eosin stained histopathology sections as the gold standard, the diagnostic sensitivity of imprint cytology was 75% and specificity was 100%. Positive predictive value was 100%. Negative predictive value was 98.74%. Imprint cytology has high sensitivity and specificity in diagnosing lesions of the thyroid. The problems faced were in diagnosing follicular carcinomas and differentiating low grade lymphoma from lymphocytic thyroiditis. Imprint cytology is a simple, reliable diagnostic technique. It has high sensitivity and specificity in intra-operative diagnosis of lesions of thyroid. In spite of the advent of newer diagnostic modalities like frozen sections, imprint cytology still holds its unique position in the current perspective.
NASA Astrophysics Data System (ADS)
Hadjigeorgiou, Katerina; Kastanos, Evdokia; Kyriakides, Alexandros; Pitris, Costas
2012-03-01
There are three stages to a complete UTI diagnosis: (1) identification of a urine sample as positive/negative for an infection, (2) identification of the responsible bacterium, (3) antibiogram to determine the antibiotic to which the bacteria are most sensitive to. Using conventional methods, all three stages require bacterial cultures in order to provide results. This long delay in diagnosis causes a rise in ineffective treatments, chronic infections, health care costs and antibiotic resistance. In this work, SERS is used to identify a sample as positive/negative for a UTI as well as to obtain an antibiogram against different antibiotics. SERS spectra of serial dilutions of E. coli bacteria mixed with silver nanoparticles, showed a linear correlation between spectral intensity and concentration. For antibiotic sensitivity testing, SERS spectra of three species of gram negative bacteria were collected four hours after exposure to the antibiotics ciprofloxacin and amoxicillin. Spectral analysis revealed clear separation between bacterial samples exposed to antibiotics to which they were sensitive and samples exposed to antibiotics to which they were resistant. With the enhancement provided by SERS, the technique can be applied directly to urine samples leading to the development of a new, rapid method for UTI diagnosis and antibiogram.
Han, Xiang-ping; Shi, Gui-lan; Wang, Cheng-feng; Li, Jie; Zhang, Jian-wei; Zhang, Yu; Zhang, Shu-ren; Liu, Bin-lei
2012-12-01
To develop a novel rapid protocol for the detection of occult disseminated tumor cells by a recombinant herpes simplex virus expressing GFP (HSV(GFP)). Tumor cells of seven cell lines were exposed to HSV(GFP) and then examined for GFP expression by fluorescence microscopy. Various numbers of tumor cells (10, 100, 1000, 10 000) were mixed into 2 ml human whole blood, separated with lymphocytes separation medium, exposed to HSV(GFP), incubated at 37°C for 6 - 24 h and then counted for the number of green cells under the fluorescence microscope. Some clinical samples including peripheral blood, pleural effusion, ascites, spinal fluid from tumor-bearing patients were screened using this protocol in parallel with routine cytological examination. HSV(GFP) was able to infect all 7 tumor cell lines indicating that the HSV(GFP) can be used to detect different types of tumor cells. The detection sensitivity was 10 cancer cells in 2 ml whole blood. In the clinical samples, there were 4/15 positive by routine cytological examination but 11/15 positive by HSV(GFP), indicating a higher sensitivity of this new protocol. Recombinant herpes simplex virus-mediated green fluorescence is a simple and sensitive technique for the identification of occult disseminated cancer cells including circulating tumor cells (CTCs).
de Mello, Cintia Xavier; Figueiredo, Fabiano Borges; Mendes Júnior, Artur Augusto Velho; Miranda, Luciana de Freitas Campos; de Oliveira, Raquel de Vasconcellos Carvalhaes; Madeira, Maria de Fátima
2016-07-06
Although direct examination methods are important for diagnosing leishmaniasis, such methods are often neglected because of their low sensitivity relative to other techniques. Our study aimed to evaluate the performance of bone marrow (BM) thick smears and cytocentrifugation tests as alternatives to direct examination for diagnosing canine visceral leishmaniasis (CVL). Ninety-two dogs exhibiting leishmaniasis seroreactivity were evaluated. The animals were euthanized; and healthy skin, spleen, popliteal lymph node, and BM puncture samples were cultured. BM cultures were used as the reference standard. Of the 92 dogs studied, 85.9% exhibited positive cultures, and Leishmania infantum (synonym Leishmania chagasi) was confirmed in all positive culture cases. The sensitivity rates for cytocentrifugation as well as thin and thick smears were 47.1%, 52.8%, and 77%, respectively. However, no association between the dogs' clinical status and culture or direct examination results was found. To our knowledge, this was the first study to use thick smears and cytocentrifugation for diagnosing CVL. Our results indicate that BM thick smears have a good sensitivity and their use reduces the time required to read slides. Therefore, thick smears can provide a rapid and safe alternative to parasitological confirmation of seroreactive dogs. © The American Society of Tropical Medicine and Hygiene.
Poisson and negative binomial item count techniques for surveys with sensitive question.
Tian, Guo-Liang; Tang, Man-Lai; Wu, Qin; Liu, Yin
2017-04-01
Although the item count technique is useful in surveys with sensitive questions, privacy of those respondents who possess the sensitive characteristic of interest may not be well protected due to a defect in its original design. In this article, we propose two new survey designs (namely the Poisson item count technique and negative binomial item count technique) which replace several independent Bernoulli random variables required by the original item count technique with a single Poisson or negative binomial random variable, respectively. The proposed models not only provide closed form variance estimate and confidence interval within [0, 1] for the sensitive proportion, but also simplify the survey design of the original item count technique. Most importantly, the new designs do not leak respondents' privacy. Empirical results show that the proposed techniques perform satisfactorily in the sense that it yields accurate parameter estimate and confidence interval.
Molecular diagnosis of strongyloidiasis in a population of an endemic area through nested-PCR.
Sharifdini, Meysam; Keyhani, Amir; Eshraghian, Mohammad Reza; Beigom Kia, Eshrat
2018-01-01
This study is aimed to diagnose and analyze strongyloidiasis in a population of an endemic area of Iran using nested-PCR, coupled with parasitological methods. Screening of strongyloidiasis infected people using reliable diagnostic techniques are essential to decrease the mortality and morbidity associated with this infection. Molecular methods have been proved to be highly sensitive and specific for detection of Strongyloides stercoralis in stool samples. A total of 155 fresh single stool samples were randomly collected from residents of north and northwest of Khouzestan Province, Iran. All samples were examined by parasitological methods including formalin-ether concentration and nutrient agar plate culture, and molecular method of nested-PCR. Infections with S. stercoralis were analyzed according to demographic criteria. Based on the results of nested-PCR method 15 cases (9.7%) were strongyloidiasis positive. Nested-PCR was more sensitive than parasitological techniques on single stool sampling. Elderly was the most important population index for higher infectivity with S. stercoralis . In endemic areas of S. stercoralis , old age should be considered as one of the most important risk factors of infection, especially among the immunosuppressed individuals.
Imaging outcome measures for progressive multiple sclerosis trials
Moccia, Marcello; de Stefano, Nicola; Barkhof, Frederik
2017-01-01
Imaging markers that are reliable, reproducible and sensitive to neurodegenerative changes in progressive multiple sclerosis (MS) can enhance the development of new medications with a neuroprotective mode-of-action. Accordingly, in recent years, a considerable number of imaging biomarkers have been included in phase 2 and 3 clinical trials in primary and secondary progressive MS. Brain lesion count and volume are markers of inflammation and demyelination and are important outcomes even in progressive MS trials. Brain and, more recently, spinal cord atrophy are gaining relevance, considering their strong association with disability accrual; ongoing improvements in analysis methods will enhance their applicability in clinical trials, especially for cord atrophy. Advanced magnetic resonance imaging (MRI) techniques (e.g. magnetization transfer ratio (MTR), diffusion tensor imaging (DTI), spectroscopy) have been included in few trials so far and hold promise for the future, as they can reflect specific pathological changes targeted by neuroprotective treatments. Position emission tomography (PET) and optical coherence tomography have yet to be included. Applications, limitations and future perspectives of these techniques in clinical trials in progressive MS are discussed, with emphasis on measurement sensitivity, reliability and sample size calculation. PMID:29041865
Lucero, David E.; Ribera, Wilma; Pizarro, Juan Carlos; Plaza, Carlos; Gordon, Levi W.; Peña, Reynaldo; Morrissey, Leslie A.; Rizzo, Donna M.; Stevens, Lori
2014-01-01
Background In this study we compared the utility of two molecular biology techniques, cloning of the mitochondrial 12S ribosomal RNA gene and hydrolysis probe-based qPCR, to identify blood meal sources of sylvatic Chagas disease insect vectors collected with live-bait mouse traps (also known as Noireau traps). Fourteen T. guasayana were collected from six georeferenced trap locations in the Andean highlands of the department of Chuquisaca, Bolivia. Methodology/Principal Findings We detected four blood meals sources with the cloning assay: seven samples were positive for human (Homo sapiens), five for chicken (Gallus gallus) and unicolored blackbird (Agelasticus cyanopus), and one for opossum (Monodelphis domestica). Using the qPCR assay we detected chicken (13 vectors), and human (14 vectors) blood meals as well as an additional blood meal source, Canis sp. (4 vectors). Conclusions/Significance We show that cloning of 12S PCR products, which avoids bias associated with developing primers based on a priori knowledge, detected blood meal sources not previously considered and that species-specific qPCR is more sensitive. All samples identified as positive for a specific blood meal source by the cloning assay were also positive by qPCR. However, not all samples positive by qPCR were positive by cloning. We show the power of combining the cloning assay with the highly sensitive hydrolysis probe-based qPCR assay provides a more complete picture of blood meal sources for insect disease vectors. PMID:25474154
DOE Office of Scientific and Technical Information (OSTI.GOV)
Teramoto, Atsushi, E-mail: teramoto@fujita-hu.ac.jp; Fujita, Hiroshi; Yamamuro, Osamu
Purpose: Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be further reduced. In this paper, the authors propose an improved FP-reduction method for the detection of pulmonary nodules in PET/CT images by means of convolutional neural networks (CNNs). Methods: The overall scheme detects pulmonary nodules using both CT and PET images. In the CT images, a massive region is first detected using anmore » active contour filter, which is a type of contrast enhancement filter that has a deformable kernel shape. Subsequently, high-uptake regions detected by the PET images are merged with the regions detected by the CT images. FP candidates are eliminated using an ensemble method; it consists of two feature extractions, one by shape/metabolic feature analysis and the other by a CNN, followed by a two-step classifier, one step being rule based and the other being based on support vector machines. Results: The authors evaluated the detection performance using 104 PET/CT images collected by a cancer-screening program. The sensitivity in detecting candidates at an initial stage was 97.2%, with 72.8 FPs/case. After performing the proposed FP-reduction method, the sensitivity of detection was 90.1%, with 4.9 FPs/case; the proposed method eliminated approximately half the FPs existing in the previous study. Conclusions: An improved FP-reduction scheme using CNN technique has been developed for the detection of pulmonary nodules in PET/CT images. The authors’ ensemble FP-reduction method eliminated 93% of the FPs; their proposed method using CNN technique eliminates approximately half the FPs existing in the previous study. These results indicate that their method may be useful in the computer-aided detection of pulmonary nodules using PET/CT images.« less
Barda, Beatrice Divina; Rinaldi, Laura; Ianniello, Davide; Zepherine, Henry; Salvo, Fulvio; Sadutshang, Tsetan; Cringoli, Giuseppe; Clementi, Massimo; Albonico, Marco
2013-01-01
Background Soil-transmitted helminths and intestinal protozoa infection are widespread in developing countries, yet an accurate diagnosis is rarely performed. The aim of this study was to evaluate the recently developed mini–FLOTAC method and to compare with currently more widely used techniques for the diagnosis of intestinal parasitic infections in different settings. Methodology/Principal Findings The study was carried out in Dharamsala, Himachal Pradesh, India, and in Bukumbi, Tanzania. A total of 180 pupils from two primary schools had their stool analyzed (n = 80 in Dharamsala and n = 100 in Bukumbi) for intestinal parasitic infections with three diagnostic methods: direct fecal smear, formol-ether concentration method (FECM) and mini-FLOTAC. Overall, 72% of the pupils were positive for any intestinal parasitic infection, 24% carried dual infections and 11% three infections or more. The most frequently encountered intestinal parasites were Entamoeba coli, Entamoeba histolytica/dispar, Giardia intestinalis, hookworm, (and Schistosoma mansoni, in Tanzania). Statistically significant differences were found in the detection of parasitic infections among the three methods: mini-FLOTAC was the most sensitive method for helminth infections (90% mini-FLOTAC, 60% FECM, and 30% direct fecal smear), whereas FECM was most sensitive for intestinal protozoa infections (88% FECM, 70% direct fecal smear, and 68% mini-FLOTAC). Conclusion/Significance We present the first experiences with the mini-FLOTAC for the diagnosis of intestinal helminths and protozoa. Our results suggest that it is a valid, sensitive and potentially low-cost alternative technique that could be used in resource-limited settings — particularly for helminth diagnosis. PMID:23936577
NASA Astrophysics Data System (ADS)
Ahn, Jae-Jun; Akram, Kashif; Kwak, Ji-Young; Jeong, Mi-Seon; Kwon, Joong-Ho
2013-10-01
Cost-effective and time-efficient analytical techniques are required to screen large food lots in accordance to their irradiation status. Gamma-irradiated (0-10 kGy) cinnamon, red pepper, black pepper, and fresh paprika were investigated using photostimulated luminescence (PSL), direct epifluorescent filter technique/the aerobic plate count (DEFT/APC), and electronic-nose (e-nose) analyses. The screening results were also confirmed with thermoluminescence analysis. PSL analysis discriminated between irradiated (positive, >5000 PCs) and non-irradiated (negative, <700 PCs) cinnamon and red peppers. Black pepper had intermediate results (700-5000 PCs), while paprika had low sensitivity (negative results) upon irradiation. The DEFT/APC technique also showed clear screening results through the changes in microbial profiles, where the best results were found in paprika, followed by red pepper and cinnamon. E-nose analysis showed a dose-dependent discrimination in volatile profiles upon irradiation through principal component analysis. These methods can be used considering their potential applications for the screening analysis of irradiated foods.
Fabrication and characterization of an egg-shaped hollow fiber microbubble
NASA Astrophysics Data System (ADS)
Wang, Guanjun; Ruan, Yinlan; Jia, Pinggang; Gui, Zhiguo; Zhang, Pengcheng; Wang, Chao; Liu, Shen; Liao, Changrui; Yin, Guolu; Wang, Yiping
2017-04-01
In this paper, an egg-shaped microbubble is proposed and analyzed firstly, which is fabricated by the pressure-assisted arc discharge technique. By tailoring the arc parameters and the position of glass tube during the fabrication process, the thinnest wall of the fabricated microbubble could reach to the level of 873nm. Then, the fiber Fabry-Perot interference technique is used to analyze the deformation of microbubble that under different filling pressures. It is found that the endface of micro-bubble occurs compression when the inner pressure increasing from 4Kpa to 1400KPa. And the pressure sensitivity of such egg-shaped microbubble sample is14.3pm/Kpa. Results of this study could be good reference for developing new pressure sensors, etc.
NASA Technical Reports Server (NTRS)
Greene, William H.
1990-01-01
A study was performed focusing on the calculation of sensitivities of displacements, velocities, accelerations, and stresses in linear, structural, transient response problems. One significant goal of the study was to develop and evaluate sensitivity calculation techniques suitable for large-order finite element analyses. Accordingly, approximation vectors such as vibration mode shapes are used to reduce the dimensionality of the finite element model. Much of the research focused on the accuracy of both response quantities and sensitivities as a function of number of vectors used. Two types of sensitivity calculation techniques were developed and evaluated. The first type of technique is an overall finite difference method where the analysis is repeated for perturbed designs. The second type of technique is termed semi-analytical because it involves direct, analytical differentiation of the equations of motion with finite difference approximation of the coefficient matrices. To be computationally practical in large-order problems, the overall finite difference methods must use the approximation vectors from the original design in the analyses of the perturbed models. In several cases this fixed mode approach resulted in very poor approximations of the stress sensitivities. Almost all of the original modes were required for an accurate sensitivity and for small numbers of modes, the accuracy was extremely poor. To overcome this poor accuracy, two semi-analytical techniques were developed. The first technique accounts for the change in eigenvectors through approximate eigenvector derivatives. The second technique applies the mode acceleration method of transient analysis to the sensitivity calculations. Both result in accurate values of the stress sensitivities with a small number of modes and much lower computational costs than if the vibration modes were recalculated and then used in an overall finite difference method.
Furuta, Rika A; Ma, Guangyong; Matsuoka, Masao; Otani, Satoshi; Matsukura, Harumichi; Hirayama, Fumiya
2015-04-01
Recently, Japanese Red Cross blood centers have changed the confirmatory test method from an indirect immunofluorescence (IF) technique to Western blotting (WB) for antibodies against human T-cell leukemia virus Type 1 (HTLV-1). In this study, these HTLV-1 tests were assessed using another sensitive method, that is, a luciferase immunoprecipitation system (LIPS), to identify a better confirmatory test for HTLV-1 infection. Plasma samples from 54 qualified donors and 114 HTLV-1 screening-positive donors were tested by LIPS for antibodies against HTLV-1 Gag, Tax, Env, and HBZ recombinant proteins. The donors were categorized into six groups, namely, (Group I) qualified donors, screening positive; (Group II) IF positive; (Group III) IF negative; (Group IV) WB positive; (Group V) WB negative; and (Group VI) screening positive in the previous blood donation, but WB-indeterminate during this study period. In Groups II and IV, all plasma samples tested positive by LIPS for antibodies against Gag and Env proteins. In Group V, all samples tested negative by LIPS, whereas some Group III samples reacted with single or double antigens in LIPS. In Group VI, the LIPS test identified a donor with suspected HTLV-1 infection. The first case of a blood donor with plasma that reacted with HBZ was identified by LIPS. Reevaluation of the current HTLV-1 screening method using the LIPS test showed that both confirmatory tests had similar sensitivity and specificity only when WB indeterminate results were eliminated. LIPS is a promising method for detecting and characterizing HTLV-1 antibodies. © 2014 AABB.
NASA Astrophysics Data System (ADS)
Hausmann, Anita; Duschek, Frank; Fischbach, Thomas; Pargmann, Carsten; Aleksejev, Valeri; Poryvkina, Larisa; Sobolev, Innokenti; Babichenko, Sergey; Handke, Jürgen
2014-05-01
The challenges of detecting hazardous biological materials are manifold: Such material has to be discriminated from other substances in various natural surroundings. The detection sensitivity should be extremely high. As living material may reproduce itself, already one single bacterium may represent a high risk. Of course, identification should be quite fast with a low false alarm rate. Up to now, there is no single technique to solve this problem. Point sensors may collect material and identify it, but the problems of fast identification and especially of appropriate positioning of local collectors are sophisticated. On the other hand, laser based standoff detection may instantaneously provide the information of some accidental spillage of material by detecting the generated thin cloud. LIF technique may classify but hardly identify the substance. A solution can be the use of LIF technique in a first step to collect primary data and - if necessary- followed by utilizing these data for an optimized positioning of point sensors. We perform studies on an open air laser test range at distances between 20 and 135 m applying LIF technique to detect and classify aerosols. In order to employ LIF capability, we use a laser source emitting two wavelengths alternatively, 280 and 355 nm, respectively. Moreover, the time dependence of fluorescence spectra is recorded by a gated intensified CCD camera. Signal processing is performed by dedicated software for spectral pattern recognition. The direct comparison of all results leads to a basic classification of the various compounds.
Recent development of the Multi-Grid detector for large area neutron scattering instruments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guerard, Bruno
2015-07-01
Most of the Neutron Scattering facilities are committed in a continuous program of modernization of their instruments, requiring large area and high performance thermal neutron detectors. Beside scintillators detectors, {sup 3}He detectors, like linear PSDs (Position Sensitive Detectors) and MWPCs (Multi-Wires Proportional Chambers), are the most current techniques nowadays. Time Of Flight instruments are using {sup 3}He PSDs mounted side by side to cover tens of m{sup 2}. As a result of the so-called '{sup 3}He shortage crisis{sup ,} the volume of 3He which is needed to build one of these instruments is not accessible anymore. The development of alternativemore » techniques requiring no 3He, has been given high priority to secure the future of neutron scattering instrumentation. This is particularly important in the context where the future ESS (European Spallation Source) will start its operation in 2019-2020. Improved scintillators represent one of the alternative techniques. Another one is the Multi-Grid introduced at the ILL in 2009. A Multi-Grid detector is composed of several independent modules of typically 0.8 m x 3 m sensitive area, mounted side by side in air or in a vacuum TOF chamber. One module is composed of segmented boron-lined proportional counters mounted in a gas vessel; the counters, of square section, are assembled with Aluminium grids electrically insulated and stacked together. This design provides two advantages: First, magnetron sputtering techniques can be used to coat B{sub 4}C films on planar substrates, and second, the neutron position along the anode wires can be measured by reading out individually the grid signals with fast shaping amplifiers followed by comparators. Unlike charge division localisation in linear PSDs, the individual readout of the grids allows operating the Multi-Grid at a low amplification gain, hence this detector is tolerant to mechanical defects and its production accessible to laboratories equipped with standard equipment. Prototypes of different configurations and sizes have been developed and tested. A demonstrator, with a sensitive area of 0.8 m x 3 m, has been studied during the CRISP European project; it contains 1024 grids, and a surface of isotopically enriched B{sub 4}C film close to 80 m{sup 2}. Its size represented a challenge in terms of fabrication and mounting of the detection elements. Another challenge was to make the gas chamber mechanically compatible with operation in a vacuum TOF chamber. Optimal working condition of this detector was achieved by flushing Ar-CO{sub 2} at a pressure of 50 mbar, and by applying 400 Volts on the anodes. This unusual gas pressure allows to greatly simplifying the mechanics of the gas vessel in vacuum. The detection efficiency has been measured with high precision for different film thicknesses. 52% has been measured at 2.5 Angstrom, in good agreement with the MC simulation. A high position resolution has been achieved by centre of gravity measurement of the TOT (Time-Over-Threshold) signals between neighbouring grids. These results, as well as other detection parameters, including gamma sensitivity and spatial uniformity, will be presented. (author)« less
Quantitative measurement of MLC leaf displacements using an electronic portal image device
NASA Astrophysics Data System (ADS)
Yang, Yong; Xing, Lei
2004-04-01
The success of an IMRT treatment relies on the positioning accuracy of the MLC (multileaf collimator) leaves for both step-and-shoot and dynamic deliveries. In practice, however, there exists no effective and quantitative means for routine MLC QA and this has become one of the bottleneck problems in IMRT implementation. In this work we present an electronic portal image device (EPID) based method for fast and accurate measurement of MLC leaf positions at arbitrary locations within the 40 cm × 40 cm radiation field. The new technique utilizes the fact that the integral signal in a small region of interest (ROI) is a sensitive and reliable indicator of the leaf displacement. In this approach, the integral signal at a ROI was expressed as a weighted sum of the contributions from the displacements of the leaf above the point and the adjacent leaves. The weighting factors or linear coefficients of the system equations were determined by fitting the integral signal data for a group of pre-designed MLC leaf sequences to the known leaf displacements that were intentionally introduced during the creation of the leaf sequences. Once the calibration is done, the system can be used for routine MLC leaf positioning QA to detect possible leaf errors. A series of tests was carried out to examine the functionality and accuracy of the technique. Our results show that the proposed technique is potentially superior to the conventional edge-detecting approach in two aspects: (i) it deals with the problem in a systematic approach and allows us to take into account the influence of the adjacent MLC leaves effectively; and (ii) it may improve the signal-to-noise ratio and is thus capable of quantitatively measuring extremely small leaf positional displacements. Our results indicate that the technique can detect a leaf positional error as small as 0.1 mm at an arbitrary point within the field in the absence of EPID set-up error and 0.3 mm when the uncertainty is considered. Given its simplicity, efficiency and accuracy, we believe that the technique is ideally suitable for routine MLC leaf positioning QA. This work was presented at the 45th Annual Meeting of American Society of Therapeutic Radiology and Oncology (ASTRO), Salt Lake City, UT, 2003. A US Patent is pending (application no. 10/197,232).
Experimental Constraints of the Exotic Shearing of Space-Time
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richardson, Jonathan William
2016-08-01
The Holometer program is a search for rst experimental evidence that space-time has quantum structure. The detector consists of a pair of co-located 40-m power-recycled interferometers whose outputs are read out synchronously at 50 MHz, achieving sensitivity to spatiallycorrelated uctuations in dierential position on time scales shorter than the light-crossing time of the instruments. Unlike gravitational wave interferometers, which time-resolve transient geometrical disturbances in the spatial background, the Holometer is searching for a universal, stationary quantization noise of the background itself. This dissertation presents the nal results of the Holometer Phase I search, an experiment congured for sensitivity to exoticmore » coherent shearing uctuations of space-time. Measurements of high-frequency cross-spectra of the interferometer signals obtain sensitivity to spatially-correlated eects far exceeding any previous measurement, in a broad frequency band extending to 7.6 MHz, twice the inverse light-crossing time of the apparatus. This measurement is the statistical aggregation of 2.1 petabytes of 2-byte dierential position measurements obtained over a month-long exposure time. At 3 signicance, it places an upper limit on the coherence scale of spatial shear two orders of magnitude below the Planck length. The result demonstrates the viability of this novel spatially-correlated interferometric detection technique to reach unprecedented sensitivity to coherent deviations of space-time from classicality, opening the door for direct experimental tests of theories of relational quantum gravity.« less
A pilot study of myofascial release therapy compared to Swedish massage in fibromyalgia.
Liptan, Ginevra; Mist, Scott; Wright, Cheryl; Arzt, Anna; Jones, Kim Dupree
2013-07-01
Fibromyalgia (FM) is characterized by widespread muscle pain and soft tissue tenderness. However, a lack of definitive muscle pathology has made FM both a diagnostic and a treatment puzzle. Much of the evidence for pathology in FM lies in the central nervous system - in particular abnormal amplification of pain signals in the spinal cord - a manifestation of central sensitization. An emerging body of evidence posits that peripheral pain generated from the muscles and fascia may trigger and maintain central sensitization in FM. Since FM patients so frequently seek manual therapy to relieve muscle symptoms, the present study compared two different manual therapy techniques in a parallel study of women with FM. Eight subjects received myofascial release (MFR) while four subjects received Swedish massage, 90 min weekly for four weeks. Overall symptom burden and physical function were assessed by the Fibromyalgia Impact Questionnaire Revised (FIQ-R). A unique challenge for the manual therapist in treating conditions involving central sensitization is to determine if localized pain reduction can be achieved with targeted therapy in the context of ongoing widespread pain. Localized pain improvement was measured by a novel questionnaire developed for this study, the modified Nordic Musculoskeletal Questionnaire (NMQ). Between-group differences in FIQ-R did not reach statistical significance, but the total change scores on FIQ-R for the MFR group (mean = 10.14, SD = 16.2) trended in the hypothesized and positive direction compared to the Swedish massage group (mean = 0.33, SD = 4.93) yielding a positive Aikin separation test. Although overall modified NMQ scores improved in both groups there were no consistent focal areas of improvement for the Swedish massage group. In contrast, the MFR group reported consistent pain reductions in the neck and upper back regions on the NMQ. These data support the need for larger randomized controlled trials of MFR versus other massage techniques and support the assessment of localized pain reduction in future manual therapy studies in FM. Copyright © 2012 Elsevier Ltd. All rights reserved.
Maudry, Arnaud; Chene, Gautier; Chatelain, Rémi; Patural, Hugues; Bellete, Bahrie; Tisseur, Bernard; Hafid, Jamal; Raberin, Hélène; Beretta, Sophie; Sung, Roger Tran Manh; Belot, Georges; Flori, Pierre
2009-09-01
A comparative study of the Toxoplasma IgG(I) and IgG(II) Access (Access I and II, respectively; Beckman Coulter Inc.), AxSYM Toxo IgG (AxSYM; Abbott Diagnostics), Vidas Toxo IgG (Vidas; bioMerieux, Marcy l'Etoile, France), Immulite Toxo IgG (Immulite; Siemens Healthcare Diagnostics Inc.), and Modular Toxo IgG (Modular; Roche Diagnostics, Basel, Switzerland) tests was done with 406 consecutive serum samples. The Toxo II IgG Western blot (LDBio, Lyon, France) was used as a reference technique in the case of intertechnique discordance. Of the 406 serum samples tested, the results for 35 were discordant by the different techniques. Using the 175 serum samples with positive results, we evaluated the standardization of the titrations obtained (in IU/ml); the medians (second quartiles) obtained were 9.1 IU/ml for the AxSYM test, 21 IU/ml for the Access I test, 25.7 IU/ml for the Access II test, 32 IU/ml for the Vidas test, 34.6 IU/ml for the Immulite test, and 248 IU/ml for the Modular test. For all the immunoassays tested, the following relative sensitivity and specificity values were found: 89.7 to 100% for the Access II test, 89.7 to 99.6% for the Immulite test, 90.2 to 99.6% for the AxSYM test, 91.4 to 99.6% for the Vidas test, 94.8 to 99.6% for the Access I test, and 98.3 to 98.7% for the Modular test. Among the 406 serum samples, we did not find any false-positive values by two different tests for the same serum sample. Except for the Modular test, which prioritized sensitivity, it appears that the positive cutoff values suggested by the pharmaceutical companies are very high (either for economical or for safety reasons). This led to imperfect sensitivity, a large number of unnecessary serological follow-ups of pregnant women, and difficulty in determining the serological status of immunosuppressed individuals.
Unified Model Deformation and Flow Transition Measurements
NASA Technical Reports Server (NTRS)
Burner, Alpheus W.; Liu, Tianshu; Garg, Sanjay; Bell, James H.; Morgan, Daniel G.
1999-01-01
The number of optical techniques that may potentially be used during a given wind tunnel test is continually growing. These include parameter sensitive paints that are sensitive to temperature or pressure, several different types of off-body and on-body flow visualization techniques, optical angle-of-attack (AoA), optical measurement of model deformation, optical techniques for determining density or velocity, and spectroscopic techniques for determining various flow field parameters. Often in the past the various optical techniques were developed independently of each other, with little or no consideration for other techniques that might also be used during a given test. Recently two optical techniques have been increasingly requested for production measurements in NASA wind tunnels. These are the video photogrammetric (or videogrammetric) technique for measuring model deformation known as the video model deformation (VMD) technique, and the parameter sensitive paints for making global pressure and temperature measurements. Considerations for, and initial attempts at, simultaneous measurements with the pressure sensitive paint (PSP) and the videogrammetric techniques have been implemented. Temperature sensitive paint (TSP) has been found to be useful for boundary-layer transition detection since turbulent boundary layers convect heat at higher rates than laminar boundary layers of comparable thickness. Transition is marked by a characteristic surface temperature change wherever there is a difference between model and flow temperatures. Recently, additional capabilities have been implemented in the target-tracking videogrammetric measurement system. These capabilities have permitted practical simultaneous measurements using parameter sensitive paint and video model deformation measurements that led to the first successful unified test with TSP for transition detection in a large production wind tunnel.
Cabrerizo, María; Calvo, Cristina; Rabella, Nuria; Muñoz-Almagro, Carmen; del Amo, Eva; Pérez-Ruiz, Mercedes; Sanbonmatsu-Gámez, Sara; Moreno-Docón, Antonio; Otero, Almudena; Trallero, Gloria
2014-11-01
Human enteroviruses (EVs) and parechoviruses (HPeVs) are important etiological agents causing infections such as meningitis, encephalitis and sepsis-like disease in neonates and young children. We have developed a real-time RT-PCR for simultaneous detection of EV and HPeV in clinical samples. Primers and probe sets were designed from the conserved 5'-noncoding region of the genomes. The sensitivity, specificity and reproducibility of the technique were measured using a set of 25 EV and 6 HPeV types. All EVs but no HPeVs were detected with the EV primers-probe set. The HPeV primers-probe set detected only the 6 HPeV types. The lower detection limit was found to be 4 and 40CCID50/ml for HPeV and EV respectively, demonstrating high sensitivity of the technique for both viruses. The threshold cycle values were highly reproducible on repeat testing of positive controls among assay runs. The assay was evaluated in 53 clinical samples of suspected meningitis, sepsis or febrile syndromes from children under 3 years. In 11 of these (21%) EVs were detected, while 4, i.e. 7.5%, were HPeV positive. Molecular typing was carried out for 73% of the viruses. In summary, the RT-PCR method developed demonstrated effectively both EV and HPeV detection, which can cause similar clinical symptoms in infants. Copyright © 2014 Elsevier B.V. All rights reserved.
Contrast enhanced ultrasound and magnetic resonance imaging in hepatocellular carcinoma diagnosis.
Dumitrescu, Cristiana I; Gheonea, Ioana A; Săndulescu, Larisa; Surlin, Valeriu; Săftoiu, Adrian; Dumitrescu, Daniela
2013-12-01
The new developments in imaging technology, including contrast enhanced ultrasound (CEUS), computed tomography (CT), and magnetic resonance imaging (MRI), allow a better diagnosis of both malignant and benign liver lesions. A retrospective trial of 126 patients was conducted in the Gastroenterology and Imaging Departments of the University of Medicine and Pharmacy Craiova, Romania. CEUS and MRI were the imaging techniques used for diagnosis of focal liver lesions (FLL), especially for hepatocellular carcinoma (HCC). Histopathology was used only in 15 cases. For each method of investigation we calculated the sensitivity, specificity, positive and negative predictive values (PPV and NPV), positive and negative likelihood ratio (+LR, -LR), accuracy and we compared the ROC curves. Statistical analysis also included the Chi-square and Kappa tests. Seventy six cases were diagnosed as HCC, with average size of 5.2±3.3 cm in diameter. The sensitivity and specificity were 71.4% and 95.6% for CEUS and 91.4%, 98.9% respectively, for MRI. When comparing the ROC curves, we found a higher area under curve for MRI (0.952) then for CEUS (0.835) (p=0.005), and 95% confidence interval of 0.0343 to 0.199. No statistically significant difference in diagnosis of FLL was found between CEUS and MRI (p > 0.05) and the agreement between the two imaging techniques was good (k = 0.78). CEUS can be used as the first step in the diagnosis of liver lesions, but MRI remains the gold standard diagnostic method for liver tumors.
Assessment of electrocardiographic criteria of left atrial enlargement.
Batra, Mahesh Kumar; Khan, Atif; Farooq, Fawad; Masood, Tariq; Karim, Musa
2018-05-01
Background Left atrial enlargement is considered to be a robust, strong, and widely acceptable indicator of cardiovascular outcomes. Echocardiography is the gold standard for measurement of left atrial size, but electrocardiography can be simple, cost-effective, and noninvasive in clinical practice. This study was undertaken to assess the diagnostic accuracy of an established electrocardiographic criterion for left atrial enlargement, taking 2-dimensional echocardiography as the gold-standard technique. Methods A cross-sectional study was conducted on 146 consecutively selected patients with the complaints of dyspnea and palpitation and with a murmur detected on clinical examination, from September 10, 2016 to February 10, 2017. Electrocardiography and echocardiography were performed in all patients. Patients with a negative P wave terminal force in lead V 1 > 40 ms·mm on electrocardiography or left atrial dimension > 40 mm on echocardiography were classified as having left atrial enlargement. Sensitivity and specificity were calculated to assess the diagnostic accuracy. Results Taking 2-dimensional echocardiography as the gold-standard technique, electrocardiography correctly diagnosed 68 patients as positive for left atrial enlargement and 12 as negative. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of electrocardiography for left atrial enlargement were 54.4%, 57.1%, 88.3%, 17.4%, and 54.8%, respectively. Conclusion The electrocardiogram appears to be a reasonable indicator of left atrial enlargement. In case of nonavailability of echocardiography, electrocardiography can be used for diagnosis of left atrial enlargement.
Suebsing, R; Kampeera, J; Tookdee, B; Withyachumnarnkul, B; Turner, W; Kiatpathomchai, W
2013-10-01
Streptococcus agalactiae and Strep. iniae are bacterial pathogens that cause streptococcosis in many fish species. An accelerated colorimetric loop-mediated isothermal amplification (LAMP) assay with pre-addition of calcein was established, and the transmission and detection of Strep. agalactiae and Strep. iniae in tilapia under natural aquatic environment were investigated. A positive reaction was observed by a colour change from orange to green through the naked eyes after completion at 63°C for 30 min with 10 times higher sensitivity than that of nested PCR assays and without cross-amplification with other fish bacterial pathogens. All sample types of Nile and red tilapia (broodstock, fertilized egg, fry) were Strep. agalactiae- and Strep. iniae positive by this new method, implying that they could be vertically transmitted. With its application for screening broodstock and fry before stocking and for monitoring fish health in grow-out ponds, the method would become very useful in fish farming industry. The application of colorimetric LAMP with pre-addition of calcein offers simple, rapid and sensitive technique with applicability for small field laboratories. This technique explored the possible vertical transmission mode of Strep. agalactiae and Strep. iniae under natural aquatic environment. It could be such preliminary data provided for the screening broodstock before breeding and/or the specific-pathogen-free production. © 2013 The Society for Applied Microbiology.
Kerhoulas, Lucy P; Kane, Jeffrey M
2012-01-01
Most dendrochronological studies focus on cores sampled from standard positions (main stem, breast height), yet vertical gradients in hydraulic constraints and priorities for carbon allocation may contribute to different growth sensitivities with position. Using cores taken from five positions (coarse roots, breast height, base of live crown, mid-crown branch and treetop), we investigated how radial growth sensitivity to climate over the period of 1895-2008 varies by position within 36 large ponderosa pines (Pinus ponderosa Dougl.) in northern Arizona. The climate parameters investigated were Palmer Drought Severity Index, water year and monsoon precipitation, maximum annual temperature, minimum annual temperature and average annual temperature. For each study tree, we generated Pearson correlation coefficients between ring width indices from each position and six climate parameters. We also investigated whether the number of missing rings differed among positions and bole heights. We found that tree density did not significantly influence climatic sensitivity to any of the climate parameters investigated at any of the sample positions. Results from three types of analyses suggest that climatic sensitivity of tree growth varied with position height: (i) correlations of radial growth and climate variables consistently increased with height; (ii) model strength based on Akaike's information criterion increased with height, where treetop growth consistently had the highest sensitivity and coarse roots the lowest sensitivity to each climatic parameter; and (iii) the correlation between bole ring width indices decreased with distance between positions. We speculate that increased sensitivity to climate at higher positions is related to hydraulic limitation because higher positions experience greater xylem tensions due to gravitational effects that render these positions more sensitive to climatic stresses. The low sensitivity of root growth to all climatic variables measured suggests that tree carbon allocation to coarse roots is independent of annual climate variability. The greater number of missing rings in branches highlights the fact that canopy development is a low priority for carbon allocation during poor growing conditions.
Silva, William P P; Stramandinoli-Zanicotti, Roberta T; Schussel, Juliana L; Ramos, Gyl H A; Ioshi, Sergio O; Sassi, Laurindo M
2016-11-01
Objective: This article concerns evaluation of the sensitivity, specificity and accuracy of FNAB for pre-surgical diagnosis of benign and malignant lesions of major and minor salivary glands of patients treated in the Department of Head and Neck Surgery of Erasto Gartner Hospital. Methods: This retrospective study analyzed medical records from January 2006 to December 2011 from patients with salivary gland lesions who underwent preoperative FNAB and, after surgical excision of the lesion, histopathological examination. Results: The study had a cohort of 130 cases, but 34 cases (26.2%) were considered unsatisfactory regarding cytology analyses. Based on the data, sensitivity was 66.7% (6/9), specificity was 81.6% (71/87), accuracy was 80.2% (77/96), the positive predictive value was 66,7% (6/9) and the negative predictive value was 81.6% (71/87). Conclusion: Despite the high rate of inadequate samples obtained in the FNAB in this study the technique offers high specificity, accuracy and acceptable sensitivity. Creative Commons Attribution License
NASA Technical Reports Server (NTRS)
Kenny, Sean P.; Hou, Gene J. W.
1994-01-01
A method for eigenvalue and eigenvector approximate analysis for the case of repeated eigenvalues with distinct first derivatives is presented. The approximate analysis method developed involves a reparameterization of the multivariable structural eigenvalue problem in terms of a single positive-valued parameter. The resulting equations yield first-order approximations to changes in the eigenvalues and the eigenvectors associated with the repeated eigenvalue problem. This work also presents a numerical technique that facilitates the definition of an eigenvector derivative for the case of repeated eigenvalues with repeated eigenvalue derivatives (of all orders). Examples are given which demonstrate the application of such equations for sensitivity and approximate analysis. Emphasis is placed on the application of sensitivity analysis to large-scale structural and controls-structures optimization problems.
Method and apparatus for real time weld monitoring
Leong, Keng H.; Hunter, Boyd V.
1997-01-01
An improved method and apparatus are provided for real time weld monitoring. An infrared signature emitted by a hot weld surface during welding is detected and this signature is compared with an infrared signature emitted by the weld surface during steady state conditions. The result is correlated with weld penetration. The signal processing is simpler than for either UV or acoustic techniques. Changes in the weld process, such as changes in the transmitted laser beam power, quality or positioning of the laser beam, change the resulting weld surface features and temperature of the weld surface, thereby resulting in a change in the direction and amount of infrared emissions. This change in emissions is monitored by an IR sensitive detecting apparatus that is sensitive to the appropriate wavelength region for the hot weld surface.
A gas-sensing array produced from screen-printed, zeolite-modified chromium titanate
NASA Astrophysics Data System (ADS)
Pugh, David C.; Hailes, Stephen M. V.; Parkin, Ivan P.
2015-08-01
Metal oxide semiconducting (MOS) gas sensors represent a cheap, robust and sensitive technology for detecting volatile organic compounds. MOS sensors have consistently been shown to lack sensitivity to a broad range on analytes, leading to false positive errors. In this study an array of five chromium titanate (CTO) thick-film sensors were produced. These were modified by incorporating a range of zeolites, namely β, Y, mordenite and ZSM5, into the bulk sensor material. Sensors were exposed to three common reducing gases, namely acetone, ethanol and toluene, and a machine learning technique was applied to differentiate between the different gases. All sensors produced strong resistive responses (increases in resistance) and a support vector machine (SVM) was able to classify the data to a high degree of selectivity.
NASA Astrophysics Data System (ADS)
Aravindran, S.; Sahilah, A. M.; Aminah, A.
2014-09-01
Halal surveillance on halal ingredients incorporated in surimi based products were studied using polymerase chain reaction (PCR)-southern hybridization on chip analysis. The primers used in this technique were targeted on mitochondria DNA (mtDNA) of cytochrome b (cyt b) gene sequence which able to differentiate 7 type (beef, chicken, duck, goat, buffalo, lamb and pork) of species on a single chip. 17 (n = 17*3) different brands of surimi-based product were purchased randomly from Selangor local market in January 2013. Of 17 brands, 3 (n = 3*3) brands were positive for chicken DNA, 1 (n = 1*3) brand was positive for goat DNA, and the remainder 13 brands (n = 13*3) have no DNA species detected. The sensitivity of PCR-southern hybridization primers to detect each meat species was 0.1 ng. In the present study, it is evidence that PCR-Southern Hybridization analysis offered a reliable result due to its highly specific and sensitive properties in detecting non-halal additive such as plasma protein incorporation in surimi-based product.
Laboratory tests for identification or exclusion of heparin induced thrombocytopenia: HIT or miss?
Favaloro, Emmanuel J
2018-02-01
Heparin induced thrombocytopenia (HIT) is a potentially fatal condition that arises subsequent to formation of antibodies against complexes containing heparin, usually platelet-factor 4-heparin ("anti-PF4-heparin"). Assessment for HIT involves both clinical evaluation and, if indicated, laboratory testing for confirmation or exclusion, typically using an initial immunological assay ("screening"), and only if positive, a secondary functional assay for confirmation. Many different immunological and functional assays have been developed. The most common contemporary immunological assays comprise enzyme-linked immunosorbent assay [ELISA], chemiluminescence, lateral flow, and particle gel techniques. The most common functional assays measure platelet aggregation or platelet activation events (e.g., serotonin release assay; heparin-induced platelet activation (HIPA); flow cytometry). All assays have some sensitivity and specificity to HIT antibodies, but differ in terms of relative sensitivity and specificity for pathological HIT, as well as false negative and false positive error rate. This brief article overviews the different available laboratory methods, as well as providing a suggested approach to diagnosis or exclusion of HIT. © 2017 Wiley Periodicals, Inc.
New developments in supra-threshold perimetry.
Henson, David B; Artes, Paul H
2002-09-01
To describe a series of recent enhancements to supra-threshold perimetry. Computer simulations were used to develop an improved algorithm (HEART) for the setting of the supra-threshold test intensity at the beginning of a field test, and to evaluate the relationship between various pass/fail criteria and the test's performance (sensitivity and specificity) and how they compare with modern threshold perimetry. Data were collected in optometric practices to evaluate HEART and to assess how the patient's response times can be analysed to detect false positive response errors in visual field test results. The HEART algorithm shows improved performance (reduced between-eye differences) over current algorithms. A pass/fail criterion of '3 stimuli seen of 3-5 presentations' at each test location reduces test/retest variability and combines high sensitivity and specificity. A large percentage of false positive responses can be detected by comparing their latencies to the average response time of a patient. Optimised supra-threshold visual field tests can perform as well as modern threshold techniques. Such tests may be easier to perform for novice patients, compared with the more demanding threshold tests.
NASA Astrophysics Data System (ADS)
Sun, Jiasong; Zhang, Yuzhen; Chen, Qian; Zuo, Chao
2017-02-01
Fourier ptychographic microscopy (FPM) is a newly developed super-resolution technique, which employs angularly varying illuminations and a phase retrieval algorithm to surpass the diffraction limit of a low numerical aperture (NA) objective lens. In current FPM imaging platforms, accurate knowledge of LED matrix's position is critical to achieve good recovery quality. Furthermore, considering such a wide field-of-view (FOV) in FPM, different regions in the FOV have different sensitivity of LED positional misalignment. In this work, we introduce an iterative method to correct position errors based on the simulated annealing (SA) algorithm. To improve the efficiency of this correcting process, large number of iterations for several images with low illumination NAs are firstly implemented to estimate the initial values of the global positional misalignment model through non-linear regression. Simulation and experimental results are presented to evaluate the performance of the proposed method and it is demonstrated that this method can both improve the quality of the recovered object image and relax the LED elements' position accuracy requirement while aligning the FPM imaging platforms.
Kocsmár, Éva; Szirtes, Ildikó; Kramer, Zsófia; Szijártó, Attila; Bene, László; Buzás, György Miklós; Kenessey, István; Bronsert, Peter; Csanadi, Agnes; Lutz, Lisa; Werner, Martin; Wellner, Ulrich Friedrich; Kiss, András; Schaff, Zsuzsa; Lotz, Gábor
2017-08-01
Conventional stainings (including H&E and special stains like Giemsa) are the most widely applied histopathologic detection methods of Helicobacter pylori (HP). We aimed to compare the diagnostic performance of Giemsa staining with immunohistochemistry (IHC) and fluorescent in situ hybridization (FISH) on a monocentric cohort of 2896 gastric biopsies and relate results to histologic alterations in order to find such histopathologic subgroups in which these methods underperform. All cases were categorized regarding presence or absence of chronic gastritis, inflammatory activity, and mucosal structural alterations. Giemsa revealed 687 cases (23.7%), IHC 795 cases (27.5%), and FISH 788 cases (27.2%) as being HP positive. Giemsa showed significantly lower overall sensitivity (83.3%) compared to IHC (98.8%) and FISH (98.0%). Moreover, the sensitivity of Giemsa dramatically dropped to 33.6% in the nonactive cases. We found that sensitivity of Giemsa strongly depends on HP density and, accordingly, on the presence of activity. Structural alterations (intestinal metaplasia, atrophy, etc.) had only no or weak effect on sensitivity of the three stainings. Both IHC and FISH proved to be equally reliable HP detecting techniques whose diagnostic performance is minimally influenced by mucosal inflammatory and structural alterations contrary to conventional stainings. We highly recommend immunohistochemistry for clinically susceptible, nonactive chronic gastritis cases, if the conventional stain-based HP detection is negative. Moreover, we recommend to use IHC more widely as basic HP stain. Helicobacter pylori FISH technique is primarily recommended to determine bacterial clarithromycin resistance. Furthermore, it is another accurate diagnostic tool for HP. © 2017 John Wiley & Sons Ltd.
Performance of the dipstick screening test as a predictor of negative urine culture
Marques, Alexandre Gimenes; Doi, André Mario; Pasternak, Jacyr; Damascena, Márcio dos Santos; França, Carolina Nunes; Martino, Marinês Dalla Valle
2017-01-01
ABSTRACT Objective To investigate whether the urine dipstick screening test can be used to predict urine culture results. Methods A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. Results The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). Conclusion A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. PMID:28444086
A 3D CZT high resolution detector for x- and gamma-ray astronomy
NASA Astrophysics Data System (ADS)
Kuvvetli, I.; Budtz-Jørgensen, C.; Zappettini, A.; Zambelli, N.; Benassi, G.; Kalemci, E.; Caroli, E.; Stephen, J. B.; Auricchio, N.
2014-07-01
At DTU Space we have developed a high resolution three dimensional (3D) position sensitive CZT detector for high energy astronomy. The design of the 3D CZT detector is based on the CZT Drift Strip detector principle. The position determination perpendicular to the anode strips is performed using a novel interpolating technique based on the drift strip signals. The position determination in the detector depth direction, is made using the DOI technique based the detector cathode and anode signals. The position determination along the anode strips is made with the help of 10 cathode strips orthogonal to the anode strips. The position resolutions are at low energies dominated by the electronic noise and improve therefore with increased signal to noise ratio as the energy increases. The achievable position resolution at higher energies will however be dominated by the extended spatial distribution of the photon produced ionization charge. The main sources of noise contribution of the drift signals are the leakage current between the strips and the strip capacitance. For the leakage current, we used a metallization process that reduces the leakage current by means of a high resistive thin layer between the drift strip electrodes and CZT detector material. This method was applied to all the proto type detectors and was a very effective method to reduce the surface leakage current between the strips. The proto type detector was recently investigated at the European Synchrotron Radiation Facility, Grenoble which provided a fine 50 × 50 μm2 collimated X-ray beam covering an energy band up to 600 keV. The Beam positions are resolved very well with a ~ 0.2 mm position resolution (FWHM ) at 400 keV in all directions.
Marcomichelakis, J; Donaldson, R; Green, J; Joseph, S; Kelly, H B; Taggart, P; Somerville, W
1980-01-01
The value of exercise testing in detecting myocardial ischaemia resulting from coronary atheroma remains controversial. In order to increase the reliability of exercise testing, all its components (asymptomatic, haemodynamic, and electrocardiographic) have been scrutinised. In this study, concerned only with the electrocardiographic response to exercise, the incorporation of beta-blockade into the standard exercise procedure has improved specificity and predictive value without affecting sensitivity. Fifty patients with anginal pain and 50 asymptomatic subjects with an abnormal electrocardiogram were investigated by exercise testing before and after beta-blockade (oxprenolol). All subjects had coronary arteriograms and left ventriculograms, and the results of exercise testing were related to the presence or absence of obstructive coronary artery disease. Possible causes of false positive exercise tests were eliminated by echocardiography. Though beta-blockade was unreliable in distinguishing ischaemic from non-ischaemic resting electrocardiograms, it eliminated all the false positive electrocardiographic responses to exercise in both groups and did not abolish any of the true positive electrocardiographic responses. Thus, specificity and predictive value were improved without reduction in sensitivity. This technique may not necessarily be applicable to other groups of patients or to a random population, but the results of this study suggest it will be a useful additional routine procedure in the investigation of coronary heart disease. PMID:7437172
Ablordeppey, Enyo A.; Drewry, Anne M.; Beyer, Alexander B.; Theodoro, Daniel L.; Fowler, Susan A.; Fuller, Brian M.; Carpenter, Christopher R.
2016-01-01
Objective We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared to chest radiography. Data Sources PubMed, EMBASE, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov Study Selection Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2×2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, inter-rater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. Data Extraction Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Data Synthesis 15 studies with 1553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 [0.77, 0.86] and 0.98 [0.97, 0.99] respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 [14.72, 65.78] and 0.25 [0.13, 0.47]. The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. Conclusions Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than chest radiography. PMID:27922877
Nabais, Celso; Figueiredo, Joana; Lopes, Paulina; Martins, Manuela; Araújo, António
2017-04-01
This study aimed to determine the relationship between CK19 mRNA copy number in sentinel lymph nodes (SLN) assessed by one-step nucleic acid amplification (OSNA) technique, and non-sentinel lymph nodes (NSLN) metastization in invasive breast cancer. A model using total tumor load (TTL) obtained by OSNA technique was also constructed to evaluate its predictability. We conducted an observational retrospective study including 598 patients with clinically T1-T3 and node negative invasive breast cancer. Of the 88 patients with positive SLN, 58 patients fulfill the inclusion criteria. In the analyzed group 25.86% had at least one positive NSLN in axillary lymph node dissection. Univariate analysis showed that tumor size, TTL and number of SLN macrometastases were predictive factors for NSLN metastases. In multivariate analysis just the TTL was predictive for positive NSLN (OR 2.67; 95% CI 1.06-6.70; P = 0.036). The ROC curve for the model using TTL alone was obtained and an AUC of 0.805 (95% CI 0.69-0.92) was achieved. For TTL >1.9 × 10 5 copies/μL we got 73.3% sensitivity, 74.4% specificity and 88.9% negative predictive value to predict NSLN metastases. When using OSNA technique to evaluate SLN, NSLN metastases can be predicted intraoperatively. This prediction tool could help in decision for axillary lymph node dissection. Copyright © 2016 Elsevier Ltd. All rights reserved.
Serological Diagnosis of Chronic Chagas Disease: Is It Time for a Change?
Abras, Alba; Gállego, Montserrat; Llovet, Teresa; Tebar, Silvia; Herrero, Mercedes; Berenguer, Pere; Ballart, Cristina; Martí, Carmen
2016-01-01
Chagas disease has spread to areas that are nonendemic for the disease with human migration. Since no single reference standard test is available, serological diagnosis of chronic Chagas disease requires at least two tests. New-generation techniques have significantly improved the accuracy of Chagas disease diagnosis by the use of a large mixture of recombinant antigens with different detection systems, such as chemiluminescence. The aim of the present study was to assess the overall accuracy of a new-generation kit, the Architect Chagas (cutoff, ≥1 sample relative light units/cutoff value [S/CO]), as a single technique for the diagnosis of chronic Chagas disease. The Architect Chagas showed a sensitivity of 100% (95% confidence interval [CI], 99.5 to 100%) and a specificity of 97.6% (95% CI, 95.2 to 99.9%). Five out of six false-positive serum samples were a consequence of cross-reactivity with Leishmania spp., and all of them achieved results of <5 S/CO. We propose the Architect Chagas as a single technique for screening in blood banks and for routine diagnosis in clinical laboratories. Only gray-zone and positive sera with a result of ≤6 S/CO would need to be confirmed by a second serological assay, thus avoiding false-positive sera and the problem of cross-reactivity with Leishmania species. The application of this proposal would result in important savings in the cost of Chagas disease diagnosis and therefore in the management and control of the disease. PMID:27053668
Observer training for computer-aided detection of pulmonary nodules in chest radiography.
De Boo, Diederick W; van Hoorn, François; van Schuppen, Joost; Schijf, Laura; Scheerder, Maeke J; Freling, Nicole J; Mets, Onno; Weber, Michael; Schaefer-Prokop, Cornelia M
2012-08-01
To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a different order by six readers. Lesion presence, location and diagnostic confidence were scored without and with CAD (IQQA-Chest, EDDA Technology) as second reader. Readers received individual feedback after each subset. Sensitivity, specificity and area under the receiver-operating characteristics curve (AUC) were calculated for readings with and without CAD with respect to change over time and impact of CAD. CAD stand-alone sensitivity was 59 % with 1.9 false-positives per image. Mean AUC slightly increased over time with and without CAD (0.78 vs. 0.84 with and 0.76 vs. 0.82 without CAD) but differences did not reach significance. The sensitivity increased (65 % vs. 70 % and 66 % vs. 70 %) and specificity decreased over time (79 % vs. 74 % and 80 % vs. 77 %) but no significant impact of CAD was found. Short-term feedback does not increase the ability of readers to differentiate true- from false-positive candidate lesions and to use CAD more effectively. • Computer-aided detection (CAD) is increasingly used as an adjunct for many radiological techniques. • Short-term feedback does not improve reader performance with CAD in chest radiography. • Differentiation between true- and false-positive CAD for low conspicious possible lesions proves difficult. • CAD can potentially increase reader performance for nodule detection in chest radiography.
Akter, Sonia; Shamsuzzaman, S M; Jahan, Ferdush
2014-08-01
This cross sectional study was conducted to identify the common bacterial causes of community acquired pneumonia (CAP) from sputum and blood by culture and polymerase chain reaction (PCR) and to evaluate the effectiveness of these tests. A total of 105 sputum and blood samples were collected from patients with pneumonia on clinical suspicion. Common causative bacterial agents of pneumonia were detected by Gram staining, cultures, biochemical tests and PCR. Among 55 sputum culture positive cases, a majority (61.82%) of the patients were in the age group between 21-50 years and the ratio between male and female was 2.5:1. Most (61.90%) of the cases were from the lower socio-economic group. Out of 105 samples, 23 (37.12%) were positive by Gram stain, 29 (27.62%) yielded growth in culture media and 37 (35.24%) were positive by PCR for Streptococcus pneumoniae and Haemophilus influenzae. Streptococcus pneumoniae was the most common aetiological agent (19.05%) followed by Klebsiella pneumoniae (13.33%), Haemophilus influenzae (8.57%) and Pseudomonas aeruginosa (5.71%). Multiplex PCR is a useful technique for rapid diagnosis of bacterial causes of pneumonia directly from sputum and blood. Considering culture as a gold standard, the sensitivity of PCR was 96.55% and specificity was 88.15%. More than 80% of Streptococcus pneumoniae isolates were found to be sensitive to ampicillin, amoxycillinclavulanate, and ceftriaxone. Susceptibilities to other antimicrobials ranged from 65% for azithromycin to 70% for levofloxacin. On the other hand, the Gram negative organisms were more sensitive to meropenem, ceftriaxone, amoxycillin-clavulanate and amikacin.
Flame Characterization Using a Tunable Solid-State Laser with Direct UV Pumping
NASA Technical Reports Server (NTRS)
Kamal, Mohammed M.; Dubinskii, Mark A.; Misra, Prabhakar
1996-01-01
Tunable solid-state lasers with direct UV pumping, based on d-f transitions of rare earth ions incorporated in wide band-gap dielectric crystals, are reliable sources of laser radiation that are suitable for excitation of combustion-related free radicals. We have employed such a laser for analytical flame characterization utilizing Laser-Induced Fluorescence (LIF) techniques. LIF spectra of alkane-air flames (used for studying combustion processes under normal and microgravity conditions) excited in the region of the A-X (0,0) OH-absorption band have been recorded and found to be both temperature-sensitive and positionally-sensitive. In addition, also clearly noticeable was the sensitivity of the spectra to the specific wavelength used for data registration. The LiCAF:Ce laser shows good prospects for being able to cover the spectral region between 280 and 340 nm and therefore be used excitation of combustion-intermediates such as the hydroxyl OH, methoxy CH30 and methylthio CH3S radicals.
Development of scanning graphene Hall probes for magnetic microscopy
NASA Astrophysics Data System (ADS)
Schaefer, Brian T.; Wang, Lei; McEuen, Paul L.; Nowack, Katja C.
We discuss our progress on developing scanning Hall probes fabricated from hexagonal boron nitride (hBN)-encapsulated graphene, with the goal to image magnetic fields with submicron resolution. In contrast to scanning superconducting quantum interference device (SQUID) microscopy, this technique is compatible with a large applied magnetic field and not limited to cryogenic temperatures. The field sensitivity of a Hall probe depends inversely on carrier density, while the primary source of noise in the measurement is Johnson noise originating from the device resistance. hBN-encapsulated graphene demonstrates high carrier mobility at low carrier densities, therefore making it an ideal material for sensitive Hall probes. Furthermore, engineering the dielectric environment of graphene by encapsulating in hBN reduces low-frequency charge noise and disorder from the substrate. We outline our plans for adapting these devices for scanning, including characterization of the point spread function with a scanned current loop and fabrication of a deep-etched structure that enables positioning the sensitive area within 100 nanometers of the sample surface.
NASA Astrophysics Data System (ADS)
Soskin, Marat S.; Denisenko, Vladimir G.; Egorov, Roman I.
2004-08-01
Polarimetry is effective technique for polarized light fields characterization. It was shown recently that most full "finger-print" of light fields with arbitrary complexity is network of polarization singularities: C points with circular polarization and L lines with variable azimuth. The new singular Stokes-polarimetry was elaborated for such measurements. It allows define azimuth, eccentricity and handedness of elliptical vibrations in each pixel of receiving CCD camera in the range of mega-pixels. It is based on precise measurement of full set of Stokes parameters by the help of high quality analyzers and quarter-wave plates with λ/500 preciseness and 4" adjustment. The matrices of obtained data are processed in PC by special programs to find positions of polarization singularities and other needed topological features. The developed SSP technique was proved successfully by measurements of topology of polarized speckle-fields produced by multimode "photonic-crystal" fibers, double side rubbed polymer films, biomedical samples. Each singularity is localized with preciseness up to +/- 1 pixel in comparison with 500 pixels dimensions of typical speckle. It was confirmed that network of topological features appeared in polarized light field after its interaction with specimen under inspection is exact individual "passport" for its characterization. Therefore, SSP can be used for smart materials characterization. The presented data show that SSP technique is promising for local analysis of properties and defects of thin films, liquid crystal cells, optical elements, biological samples, etc. It is able discover heterogeneities and defects, which define essentially merits of specimens under inspection and can"t be checked by usual polarimetry methods. The detected extra high sensitivity of polarization singularities position and network to any changes of samples position and deformation opens quite new possibilities for sensing of deformations and displacement of checked elements in the sub-micron range.
Hjelmeland, Anna K; Wylie, Philip L; Ebeler, Susan E
2016-02-01
Methoxypyrazines are volatile compounds found in plants, microbes, and insects that have potent vegetal and earthy aromas. With sensory detection thresholds in the low ng L(-1) range, modest concentrations of these compounds can profoundly impact the aroma quality of foods and beverages, and high levels can lead to consumer rejection. The wine industry routinely analyzes the most prevalent methoxypyrazine, 2-isobutyl-3-methoxypyrazine (IBMP), to aid in harvest decisions, since concentrations decrease during berry ripening. In addition to IBMP, three other methoxypyrazines IPMP (2-isopropyl-3-methoxypyrazine), SBMP (2-sec-butyl-3-methoxypyrazine), and EMP (2-ethyl-3-methoxypyrazine) have been identified in grapes and/or wine and can impact aroma quality. Despite their routine analysis in the wine industry (mostly IBMP), accurate methoxypyrazine quantitation is hindered by two major challenges: sensitivity and resolution. With extremely low sensory detection thresholds (~8-15 ng L(-1) in wine for IBMP), highly sensitive analytical methods to quantify methoxypyrazines at trace levels are necessary. Here we were able to achieve resolution of IBMP as well as IPMP, EMP, and SBMP from co-eluting compounds using one-dimensional chromatography coupled to positive chemical ionization tandem mass spectrometry. Three extraction techniques HS-SPME (headspace-solid phase microextraction), SBSE (stirbar sorptive extraction), and HSSE (headspace sorptive extraction) were validated and compared. A 30 min extraction time was used for HS-SPME and SBSE extraction techniques, while 120 min was necessary to achieve sufficient sensitivity for HSSE extractions. All extraction methods have limits of quantitation (LOQ) at or below 1 ng L(-1) for all four methoxypyrazines analyzed, i.e., LOQ's at or below reported sensory detection limits in wine. The method is high throughput, with resolution of all compounds possible with a relatively rapid 27 min GC oven program. Copyright © 2015 Elsevier B.V. All rights reserved.
Carrillo, Sergio A; Daniel, Vincent C; Hall, Nathan; Hitchcock, Charles L; Ross, Patrick; Kassis, Edmund S
2012-05-01
The 5-year survival for patients with resected stage II (N1) non-small cell lung cancer ranges from 40% to 55%. No data exist addressing the benefit of neoadjuvant therapy for patients with stage II disease. This is largely in part due to the lack of a reliable, minimally invasive method to assess hilar nodes. This study is aimed at determining the ability of fusion positron emission/computed tomography (PET/CT) to identify hilar metastases in patients with resected non-small cell lung cancer. A retrospective review of surgically resected patients with fusion PET/CT within 30 days of resection was performed. The sensitivity, specificity, positive predictive value, and negative predictive value for PET/CT in detecting hilar nodal metastases was calculated for a range of maximum standardized uptake values (SUVmax). Hilar nodes from patients with falsely positive PET/CT scans were analyzed for the presence of histoplasmosis. Additionally, the impact of hilar node size greater than 1 centimeter on the calculated values was assessed. There were 119 patients evaluated. The number of lymph nodes resected ranged from 1 to 12 (X=2.98). There was decreased sensitivity and increased specificity with higher SUVmax cutoff values. At the standard SUVmax value of 2.5, the sensitivity and specificity were only 48.5% and 80.2%. The addition of size of hilar node by CT led to a modest improvement in sensitivity at all SUVmax cutoff values. Fusion PET/CT lacks sensitivity and specificity in identifying hilar nodal metastasis in patients with resected non-small cell lung cancer. Further prospective studies assessing the utility of PET/CT versus alternative sampling techniques are warranted. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Microarray-based IgE detection in tears of patients with vernal keratoconjunctivitis.
Leonardi, Andrea; Borghesan, Franco; Faggian, Diego; Plebani, Mario
2015-11-01
A specific allergen sensitization can be demonstrated in approximately half of the vernal keratoconjunctivitis (VKC) patients by conventional allergic tests. The measurement of specific IgE in tears using a multiplex allergen microarray may offer advantages to identify local sensitization to a specific allergen. In spring-summer 2011, serum and tears samples were collected from 10 active VKC patients (three females, seven males) and 10 age-matched normal subjects. Skin prick test, symptoms score and full ophthalmological examination were performed. Specific serum and tear IgE were assayed using ImmunoCAP ISAC, a microarray containing 103 components derived from 47 allergens. Normal subjects resulted negative for the presence of specific IgE both in serum and in tears. Of the 10 VKC patients, six resulted positive to specific IgE in serum and/or tears. In three of these six patients, specific IgE was found positive only in tears. Cross-reactivity between specific markers was found in three patients. Grass, tree, mites, animal but also food allergen-specific IgE were found in tears. Conjunctival provocation test performed out of season confirmed the specific local conjunctival reactivity. Multiple specific IgE measurements with single protein allergens using a microarray technique in tear samples are a useful, simple and non-invasive diagnostic tool. ImmunoCAP ISAC detects allergen sensitization at component level and adds important information by defining both cross- and co-sensitization to a large variety of allergen molecules. The presence of specific IgE only in tears of VKC patients reinforces the concept of possible local sensitization. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Kocer, Derya; Sarıguzel, Fatma M; Karakukcu, Cıgdem
2014-08-01
The microscopic analysis of urine is essential for the diagnosis of patients with urinary tract infections. Quantitative urine culture is the 'gold standard' method for definitive diagnosis of urinary-tract infections, but it is labor-intensive, time consuming, and does not provide the same-day results. The aim of this study was to evaluate the analytical and diagnostic performance of the FUS200 (Changchun Dirui Industry, China), a new urine sedimentation analyzer in comparison to urine culture as the reference method. We evaluated 1000 urine samples, submitted for culture and urine analysis with a preliminary diagnosis of urinary-tract infection. Cut-off values for the FUS200 were determined by comparing the results with urine cultures. The cut-off values by the receiver operating characteristic (ROC) curve technique, sensitivity, and specificity were calculated for bacteria and white blood cells (WBCs). Among the 1000 urine specimens submitted for culture, 637 cultures (63.7%) were negative, and 363 were (36.3%) positive. The best cut-off values obtained from ROC analysis were 16/μL for bacteriuria (sensitivity: 82.3%, specificity: 58%), and 34/μL for WBCs (sensitivity: 72.3%, specificity: 65.2%). The area under the curve (AUC) for the bacteria and WBCs count were 0.71 (95% CI: 0.67-0.74) and, 0.72 (95% CI: 0.69-0.76) respectively. The most important requirement of a rapid diagnostic screening test is sensitivity, and, in this perspective, an unsatisfactory sensitivity by using bacteria recognition and quantification performed by the FUS200 analyzer has been observed. After further technical improvements in particle recognition and laboratory personnel training, the FUS200 might show better results.
Keo, Hong H; Schilling, Marianne; Büchel, Roland; Gröchenig, Ernst; Engelberger, Rolf P; Willenberg, Torsten; Baumgartner, Iris; Gretener, Silvia B
2013-06-01
Fluorescence microlymphography (FML) is used to visualize the lymphatic capillaries. A maximum spread of the fluorescence dye of ≥ 12 mm has been suggested for the diagnosis of lymphedema. However, data on sensitivity and specificity are lacking. The aim of this study was to investigate the accuracy of FML for diagnosing lymphedema in patients with leg swelling. Patients with lower extremity swelling were clinically assessed and separated into lymphedema and non-lymphatic edema groups. FML was studied in all affected legs and the maximum spread of lymphatic capillaries was measured. Test accuracy and receiver operator characteristic (ROC) analysis was performed to assess possible threshold values that predict lymphedema. Between March 2008 and August 2011 a total of 171 patients (184 legs) with a median age of 43.5 (IQR 24, 54) years were assessed. Of those, 94 (51.1%) legs were diagnosed with lymphedema. The sensitivity, specificity, positive and negative likelihood ratio and positive and negative predictive value were 87%, 64%, 2.45, 0.20, 72% and 83% for the 12-mm cut-off level and 79%, 83%, 4.72, 0.26, 83% and 79% for the 14-mm cut-off level, respectively. The area under the ROC curve was 0.82 (95% CI: 0.76, 0.88). Sensitivity was higher in the secondary versus primary lymphedema (95.0% vs 74.3%, p = 0.045). No major adverse events were observed. In conclusion, FML is a simple and safe technique for detecting lymphedema in patients with leg swelling. A cut-off level of ≥ 14-mm maximum spread has a high sensitivity and high specificity of detecting lymphedema and should be chosen.
Chemical analysis of acoustically levitated drops by Raman spectroscopy.
Tuckermann, Rudolf; Puskar, Ljiljana; Zavabeti, Mahta; Sekine, Ryo; McNaughton, Don
2009-07-01
An experimental apparatus combining Raman spectroscopy with acoustic levitation, Raman acoustic levitation spectroscopy (RALS), is investigated in the field of physical and chemical analytics. Whereas acoustic levitation enables the contactless handling of microsized samples, Raman spectroscopy offers the advantage of a noninvasive method without complex sample preparation. After carrying out some systematic tests to probe the sensitivity of the technique to drop size, shape, and position, RALS has been successfully applied in monitoring sample dilution and preconcentration, evaporation, crystallization, an acid-base reaction, and analytes in a surface-enhanced Raman spectroscopy colloidal suspension.
MR arthrography in chondromalacia patellae diagnosis on a low-field open magnet system.
Harman, Mustafa; Ipeksoy, Umit; Dogan, Ali; Arslan, Halil; Etlik, Omer
2003-01-01
The purpose of this study was to compare the diagnostic efficacy conventional MRI and MR arthrography (MRA) in the diagnosis of chondromalacia patella (CP) on a low-field open magnet system (LFOMS), correlated with arthroscopy. Forty-two patients (50 knees) with pain in the anterior part of the knee were prospectively examined with LFOMS, including T1-weighted, proton density-weighted and T2-weighted sequences. All were also examined T1-weighted MRI after intraarticular injection of dilue gadopentetate dimeglumine. Two observers, who reached a consensus interpretation, evaluated each imaging technique independently. Thirty-six of the 50 facets examined had chondromalacia shown by arthroscopy, which was used as the standard of reference. The sensitivity, specificity and accuracy of each imaging technique in the diagnosis of each stage of CP were determined and compared by using the McNemar two-tailed analysis. Arthroscopy showed that 16 facets were normal. Four (30%) of 13 grade 1 lesions were detected with T1. Four lesions (30%) with T2 and three lesions (23%) with proton-weighted images were detected. Seven (53%) of 13 grade 1 lesions were detected with MRA. Grade 2 abnormalities were diagnosed in two (33%) of six facets with proton density-weighted pulse sequences, two (33%) of six facets with T1-weighted pulse sequences, in three (50%) of six facets with T2-weighted pulse sequences, in five (83%) of six facets with MRA sequences. Grade 3 abnormalities were diagnosed in three (71%) of seven facets with proton density- and T1-weighted images, five (71%) of seven facets with T2-weighted pulse sequences, six (85%) of seven facets with MRA sequences. Grade 4 CP was detected with equal sensitivity with T1-, proton density- and T2-weighted pulse sequences, all showing seven (87%) of the eight lesions. MRA again showed these findings in all eight patients. All imaging techniques were insensitive to grade 1 lesions and highly sensitive to grade 4 lesion, so that no significant difference among the techniques could be shown. All imaging technique studied had high specificity and accuracy in the detection and grading of CP; however, MRA was more sensitive than T1-weighted and proton density-weighted MR imaging on a LFOMS. Although the arthrographic techniques were not significantly better than T2-weighted imaging, the number of false-positive diagnosis was greatest with T2-weighted MRI.
Gunse, B.; Poschenrieder, C.; Barcelo, J.
1997-01-01
Root and root cell pressure-probe techniques were used to investigate the possible relationship between Al- or H+-induced alterations of the hydraulic conductivity of root cells (LPc) and whole-root water conductivity (LPr) in maize (Zea mays L.) plants. To distinguish between H+ and Al effects two varieties that differ in H+ and Al tolerance were assayed. Based on root elongation rates after 24 h in nutrient solution of pH 6.0, pH 4.5, or pH 4.5 plus 50 [mu]M Al, the variety Adour 250 was found to be H+-sensitive and Al-tolerant, whereas the variety BR 201 F was found to be H+-tolerant but Al-sensitive. No Al-induced decrease of root pressure and root cell turgor was observed in Al-sensitive BR 201 F, indicating that Al toxicity did not cause a general breakdown of membrane integrity and that ion pumping to the stele was maintained. Al reduced LPc more than LPr in Al-sensitive BR 201 F. Proton toxicity in Adour 250 affected LPr more than LPc. In this Al-tolerant variety LPc was increased by Al. Nevertheless, this positive effect on LPc did not render higher LPr values. In conclusion, there were no direct relationships between Al- or H+-induced decreases of LPr and the effects on LPc. To our knowledge, this is the first time that the influence of H+ and Al on root and root cell water relations has been directly measured by pressure-probe techniques. PMID:12223628
Wang, Jinlin; Zhou, Xinghua; Xie, Xiaohong; Tang, Qing; Shen, Panxiao; Zeng, Yunxiang
2016-11-17
The most efficient approach to diagnose malignant pleural effusions (MPEs) is still controversial and uncertain. This study aimed to evaluate the utility of a combined approach using ultrasound (US)-guided cutting-needle biopsy (CNB) and standard pleural biopsy (SPB) for diagnosing MPE. Pleural effusions were collected from 172 patients for biochemical and microbiological analyses. US-guided CNB and SPB were performed in the same operation sequentially to obtain specimens for histological analysis. US-guided CNB and SPB procedures provided adequate material for histological analysis in 90.7 and 93.0% of cases, respectively, while a combination of the 2 techniques was in 96.5% of cases. The sensitivity, specificity, positive-predictive value (PPV), negative-predictive value (NPV) and diagnostic accuracy of US-guided CNB versus SPB were: 51.2 vs 63.4%, 100 vs 100%, 100 vs 100%, 64.9 vs 72.2% and 74.4 vs 81.3%, respectively. When CNB was combined with SPB, the corresponding values were 88.6, 100, 100, 88.6 and 93.9%, respectively. Whereas sensitivity, NPV and diagnostic accuracy were not significantly different between CNB and SPB, the combination of CNB and SPB significantly improved the sensitivity, NPV and diagnostic accuracy versus each technique alone (p < 0.05). Significant pain (eight patients), moderate haemoptysis (two patients) and chest wall haematomas (two patients) were observed following CNB, while syncope (four patients) and a slight pneumothorax (four patients) were observed following SPB. Use of a combination of US-guided CNB and SPB afforded a high sensitivity to diagnose MPEs, it is a convenient and safe approach.
Verification of intravenous catheter placement by auscultation--a simple, noninvasive technique.
Lehavi, Amit; Rudich, Utay; Schechtman, Moshe; Katz, Yeshayahu Shai
2014-01-01
Verification of proper placement of an intravenous catheter may not always be simple. We evaluated the auscultation technique for this purpose. Twenty healthy volunteers were randomized for 18G catheter inserted intravenously either in the right (12) or left arm (8), and subcutaneously in the opposite arm. A standard stethoscope was placed over an area approximately 3 cm proximal to the tip of the catheter in the presumed direction of the vein to grade on a 0-6 scale the murmur heard by rapidly injecting 2 mL of NaCl 0.9% solution. The auscultation was evaluated by a blinded staff anesthesiologist. All 20 intravenous injection were evaluated as flow murmurs, and were graded an average 5.65 (±0.98), whereas all 20 subcutaneous injections were evaluated as either crackles or no sound, and were graded an average 2.00 (±1.38), without negative results. Sensitivity was calculated as 95%. Specificity and Kappa could not be calculated due to an empty false-positive group. Being simple, handy and noninvasive, we recommend to use the auscultation technique for verification of the proper placement of an intravenous catheter when uncertain of its position. Data obtained in our limited sample of healthy subjects need to be confirmed in the clinical setting.
NASA Astrophysics Data System (ADS)
Zeqiri, B.; Žauhar, G.; Rajagopal, S.; Pounder, A.
2012-06-01
A systematic study of the application of a novel pyroelectric technique to the measurement of diagnostic-level medical ultrasound output power is described. The method exploits the pyroelectric properties of a 0.028 mm thick membrane of polyvinylidene fluoride (PVDF), backed by an acoustic absorber whose ultrasonic absorption coefficient approaches 1000 dB cm-1 at 3 MHz. When exposed to an ultrasonic field, absorption of ultrasound adjacent to the PVDF-absorber interface results in heating and the generation of a pyroelectric output voltage across gold electrodes deposited on the membrane. For a sensor large enough to intercept the whole of the acoustic beam, the output voltage can be calibrated for the measurement of acoustic output power. A number of key performance properties of the method have been investigated. The technique is very sensitive, with a power to voltage conversion factor of typically 0.23 V W-1. The frequency response of a particular embodiment of the sensor in which acoustic power reflected at the absorber-PVDF interface is subsequently returned to the pyroelectric membrane to be absorbed, has been evaluated over the frequency range 1.5 MHz to 10 MHz. This has shown the frequency response to be flat to within ±4%, above 2.5 MHz. Below this frequency, the sensitivity falls by 20% at 1.5 MHz. Linearity of the technique has been demonstrated to within ±1.6% for applied acoustic power levels from 1 mW up to 120 mW. A number of other studies targeted at assessing the achievable measurement uncertainties are presented. These involve: the effects of soaking, the influence of the angle of incidence of the acoustic beam, measurement repeatability and sensitivity to transducer positioning. Additionally, over the range 20 °C to 30 °C, the rate of change in sensitivity with ambient temperature has been shown to be +0.5% °C-1. Implications of the work for the development of a sensitive, traceable, portable, secondary method of ultrasound output power measurement, appropriate for clinical diagnostic ultrasound systems, are discussed.
Mini-FLOTAC and Kato-Katz: helminth eggs watching on the shore of Lake Victoria.
Barda, Beatrice; Zepherine, Henry; Rinaldi, Laura; Cringoli, Giuseppe; Burioni, Roberto; Clementi, Massimo; Albonico, Marco
2013-07-31
One of the challenges for monitoring helminth control programmes based on preventive chemotherapy is the lack of a copro-parasitological gold-standard method that combines good sensitivity with quantitative performance, low cost, and easy-to-learn technique.The aim of our study was to evaluate and compare, the WHO recommended quantitative diagnostic technique (Kato-Katz) and the Mini-FLOTAC. Mini-FLOTAC is an innovative method based on floatation of helminths eggs with two different solutions (FS2 and FS7) using a close system (Fill-FLOTAC) with 5% fixative. Kato-Katz was performed following WHO recommendation. The study was carried out in a rural part of Tanzania, close to Lake Victoria, where the laboratory facilities are fairly scarce, and the basic technique used in the local laboratory (direct smear) was taken as reference standard. 201 children were screened for intestinal helminths and 91% of them were found to be positive. The agreement among the three techniques was calculated with k Cohen coefficient and was fairly good (k = 0.4), although the Mini-FLOTAC results were more sensitive for hookworm (98%) with FS2, and for S.mansoni (90%) with FS7 followed by Kato-Katz (91% and 60% respectively) and direct smear (30% and 10% respectively). A good agreement was found between Mini-FLOTAC and Kato-Katz (k = 0.81) with FS7 (k = 0.76) for hookworm diagnosis and a fairly good one for S.mansoni diagnosis (k = 0.5). For both infections we had a poor agreement between the two quantitative techniques and the direct smear (k<0.3). Kato-Katz diagnosed a higher number of eggs (calculated by arithmetic mean) both for hookworm (455 vs 424 EPG) and for S.mansoni (71 vs 58 EPG) compared with the Mini-FLOTAC, but the differences were not significant (p = 0.4). Mini-FLOTAC is a promising technique, comparable and as sensitive as the Kato-Katz, which is the recommended method in intestinal helminthology for monitoring helminth control programmes. A comparative advantage of the Mini-FLOTAC is that it comprises of a closed system with preserved samples that both protects the operators and allows subsequent examination of the samples. Further studies are needed to validate the mini-FLOTAC with other quantitative techniques (McMaster) and in different settings where other soil-transmitted helminths are also endemic.
NASA Astrophysics Data System (ADS)
Matheus, B. R. N.; Centurion, B. S.; Rubira-Bullen, I. R. F.; Schiabel, H.
2017-03-01
Cone Beam Computed Tomography (CBCT), a kind of face and neck exams can be opportunity to identify, as an incidental finding, calcifications of the carotid artery (CACA). Given the similarity of the CACA with calcification found in several x-ray exams, this work suggests that a similar technique designed to detect breast calcifications in mammography images could be applied to detect such calcifications in CBCT. The method used a 3D version of the calcification detection technique [1], based on a signal enhancement using a convolution with a 3D Laplacian of Gaussian (LoG) function followed by removing the high contrast bone structure from the image. Initial promising results show a 71% sensitivity with 0.48 false positive per exam.
Adaptive optics and interferometry
NASA Technical Reports Server (NTRS)
Beichman, Charles A.; Ridgway, Stephen
1991-01-01
Adaptive optics and interferometry, two techniques that will improve the limiting resolution of optical and infrared observations by factors of tens or even thousands, are discussed. The real-time adjustment of optical surfaces to compensate for wavefront distortions will improve image quality and increase sensitivity. The phased operation of multiple telescopes separated by large distances will make it possible to achieve very high angular resolution and precise positional measurements. Infrared and optical interferometers that will manipulate light beams and measure interference directly are considered. Angular resolutions of single telescopes will be limited to around 10 milliarcseconds even using the adaptive optics techniques. Interferometry would surpass this limit by a factor of 100 or more. Future telescope arrays with 100-m baselines (resolution of 2.5 milliarcseconds at a 1-micron wavelength) are also discussed.
Comparative investigation of diagnosis media for induction machine mechanical unbalance fault.
Salah, Mohamed; Bacha, Khmais; Chaari, Abdelkader
2013-11-01
For an induction machine, we suggest a theoretical development of the mechanical unbalance effect on the analytical expressions of radial vibration and stator current. Related spectra are described and characteristic defect frequencies are determined. Moreover, the stray flux expressions are developed for both axial and radial sensor coil positions and a substitute diagnosis technique is proposed. In addition, the load torque effect on the detection efficiency of these diagnosis media is discussed and a comparative investigation is performed. The decisive factor of comparison is the fault sensitivity. Experimental results show that spectral analysis of the axial stray flux can be an alternative solution to cover effectiveness limitation of the traditional stator current technique and to substitute the classical vibration practice. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.
Large-volume protein crystal growth for neutron macromolecular crystallography.
Ng, Joseph D; Baird, James K; Coates, Leighton; Garcia-Ruiz, Juan M; Hodge, Teresa A; Huang, Sijay
2015-04-01
Neutron macromolecular crystallography (NMC) is the prevailing method for the accurate determination of the positions of H atoms in macromolecules. As neutron sources are becoming more available to general users, finding means to optimize the growth of protein crystals to sizes suitable for NMC is extremely important. Historically, much has been learned about growing crystals for X-ray diffraction. However, owing to new-generation synchrotron X-ray facilities and sensitive detectors, protein crystal sizes as small as in the nano-range have become adequate for structure determination, lessening the necessity to grow large crystals. Here, some of the approaches, techniques and considerations for the growth of crystals to significant dimensions that are now relevant to NMC are revisited. These include experimental strategies utilizing solubility diagrams, ripening effects, classical crystallization techniques, microgravity and theoretical considerations.
2016-01-01
This work demonstrates the feasibility of making sensitive nanometer distance measurements between Fe(III) heme centers and nitroxide spin labels in proteins using the double electron–electron resonance (DEER) pulsed EPR technique at 94 GHz. Techniques to measure accurately long distances in many classes of heme proteins using DEER are currently strongly limited by sensitivity. In this paper we demonstrate sensitivity gains of more than 30 times compared with previous lower frequency (X-band) DEER measurements on both human neuroglobin and sperm whale myoglobin. This is achieved by taking advantage of recent instrumental advances, employing wideband excitation techniques based on composite pulses and exploiting more favorable relaxation properties of low-spin Fe(III) in high magnetic fields. This gain in sensitivity potentially allows the DEER technique to be routinely used as a sensitive probe of structure and conformation in the large number of heme and many other metalloproteins. PMID:27035368
Enhancement of sun-tracking with optoelectronic devices
NASA Astrophysics Data System (ADS)
Wu, Jiunn-Chi
2015-09-01
Sun-tracking is one of the most challenging tasks in implementing CPV. In order to justify the additional complexity of sun-tracking, careful assessment of performance of CPV by monitoring the performance of sun-tracking is vital. Measurement of accuracy of sun-tracking is one of the important tasks in an outdoor test. This study examines techniques with three optoelectronic devices (i.e. position sensitive device (PSD), CCD and webcam). Outdoor measurements indicated that during sunny days (global horizontal insolation (GHI) > 700 W/m2), three devices recorded comparable tracking accuracy of 0.16˜0.3°. The method using a PSD has fastest sampling rate and is able to detect the sun's position without additional image processing. Yet, it cannot identify the sunlight effectively during low insolation. The techniques with a CCD and a webcam enhance the accuracy of centroid of sunlight via the optical lens and image processing. The image quality acquired using a webcam and a CCD is comparable but the webcam is more affordable than that of CCD because it can be assembled with consumer-graded products.
Tube and column agglutination technology for autocontrol testing.
Courtney, J E; Vincent, J L; Indrikovs, A J
2001-01-01
The incidence of positive autocontrol test results with column agglutination technology is a concern. This study investigates the incidence and significance of positive autocontrols in the ID Micro Typing System (gel) and the Gamma ReACT (ReACT). The study encompassed a total of 1021 randomly selected samples from patients and 95 samples from donors collected during 1 month. The autocontrol testing was carried out according to the manufacturer's instructions for the column agglutination tests. The tube method was carried out using low-ionic-strength solution (LISS). The direct antiglobulin test (DAT) was performed using the tube method, and further investigated with elution studies if warranted. Seventy-nine patient's samples (7.74%) had a positive autocontrol: the gel test, 72 (91.13%); ReACT, 21 (26.58%); and the tube method, 27 (34.18%). Of the 79 positive autocontrols, 44 samples had a negative DAT. Of the samples with positive DAT results, only one possessed a clinically significant antibody, anti-D. Moreover, the same sample also tested positive in all three methods. Column agglutination techniques have increased sensitivity for a positive autocontrol beyond the conventional tube method. However, ReACT and gel tests differ significantly in their frequency of positives. Investigation of the significance of a positive autocontrol in column agglutination technology when the conventional tube method is also positive is suggested.
Wang, D N; Wu, W J; Wang, T; Pan, Y Z; Tang, K L; She, X L; Ding, W J; Wang, H
2015-05-01
Bacterial L-forms have always been considered as osmotic-pressure-sensitive cell-wall-deficient bacteria and isolation culture of L-forms must use media with high osmotic pressure. However, isolation culture of stable L-forms formed in humans and animals is very difficult because they have adapted to the physiological osmotic pressure condition of the host. We use a non-high osmotic isolation technique to isolate stable L-forms of Salmonella Typhi and Salmonella Paratyphi A from bile-inducer cultures in vitro and from patients' gallbladder specimens. Multiplex PCR assay for Salmonella-specific genes and nucleotide sequencing are used to identify the Salmonella L-forms in stable L-form isolates. Using this method, we confirmed that Salmonella Paratyphi A and Salmonella Typhi cannot be isolated from bile-inducer cultures cultured for 6 h or 48 h, but the L-forms can be isolated from 1 h to 45 days. In the 524 gallbladder samples, the positive rate for bacterial forms was 19.7% and the positive rate for Salmonella spp. was 0.6% by routine bacteriological methods. The positive rate for bacterial L-forms was 75.4% using non-high osmotic isolation culture. In the L-form isolates, the positive rate of Salmonella invA gene was 3.1%. In these invA-positive L-form isolates, four were positive for the invA and flic-d genes of Salmonella Typhi, and ten were positive for the invA and flic-a genes of Salmonella Paratyphi A. Copyright © 2014 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Study of false positives in 5-ALA induced photodynamic diagnosis of bladder carcinoma
NASA Astrophysics Data System (ADS)
Draga, Ronald O. P.; Grimbergen, Matthijs C. M.; Kok, Esther T.; Jonges, Trudy G. N.; Bosch, J. L. H. R.
2009-02-01
Photodynamic diagnosis (PDD) is a technique that enhances the detection of tumors during cystoscopy using a photosensitizer which accumulates primarily in cancerous cells and will fluoresce when illuminated by violetblue light. A disadvantage of PDD is the relatively low specificity. In this retrospective study we aimed to identify predictors for false positive findings in PDD. Factors such as gender, age, recent transurethral resection of bladder tumors (TURBT), previous intravesical therapy (IVT) and urinary tract infections (UTIs) were examined for association with the false positive rates in a multivariate analysis. Data of 366 procedures and 200 patients were collected. Patients were instilled with 5-aminolevulinic acid (5-ALA) intravesically and 1253 biopsies were taken from tumors and suspicious lesions. Female gender and TURBT are independent predictors of false positives in PDD. However, previous intravesical therapy with Bacille Calmette-Guérin is also an important predictor of false positives. The false positive rate decreases during the first 9-12 weeks after the latest TURBT and the latest intravesical chemotherapy. Although shortly after IVT and TURBT false positives increase, PDD improves the diagnostic sensitivity and results in more adequate treatment strategies in a significant number of patients.
Bittersohl, Bernd; Kircher, Jörn; Miese, Falk R; Dekkers, Christin; Habermeyer, Peter; Fröbel, Julia; Antoch, Gerald; Krauspe, Rüdiger; Zilkens, Christoph
2015-10-01
Cartilage biochemical imaging modalities that include the magnetic resonance imaging (MRI) techniques of T2* mapping (sensitive to water content and collagen fiber network) and delayed gadolinium-enhanced MRI of cartilage (dGEMRIC, sensitive to the glycosaminoglycan content) can be effective instruments for early diagnosis and reliable follow-up of cartilage damage. The purpose of this study was to provide T2* mapping and dGEMRIC values in various histologic grades of cartilage degeneration in humeral articular cartilage. A histologically controlled in vitro study was conducted that included human humeral head cartilage specimens with various histologic grades of cartilage degeneration. High-resolution, 3-dimensional (3D) T2* mapping and dGEMRIC were performed that enabled the correlation of MRI and histology data. Cartilage degeneration was graded according to the Mankin score, which evaluates surface morphology, cellularity, toluidine blue staining, and tidemark integrity. SPSS software was used for statistical analyses. Both MRI mapping values decreased significantly (P < .001) with increasing cartilage degeneration. Spearman rank analysis revealed a significant correlation (correlation coefficients ranging from -0.315 to 0.784; P < .001) between the various histologic parameters and the T2* and T1Gd mapping values. This study demonstrates the feasibility of 3D T2* and dGEMRIC to identify various histologic grades of cartilage damage of humeral articular cartilage. With regard to the advantages of these mapping techniques with high image resolution and the ability to accomplish a 3D biochemically sensitive imaging, we consider that these imaging techniques can make a positive contribution to the currently evolving science and practice of cartilage biochemical imaging. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Biasetti, Jacopo; Sampath, Kaushik; Cortez, Angel; Azhir, Alaleh; Gilad, Assaf A; Kickler, Thomas S; Obser, Tobias; Ruggeri, Zaverio M; Katz, Joseph
2017-01-01
Tracking cells and proteins' phenotypic changes in deep suspensions is critical for the direct imaging of blood-related phenomena in in vitro replica of cardiovascular systems and blood-handling devices. This paper introduces fluorescence imaging techniques for space and time resolved detection of platelet activation, von Willebrand factor (VWF) conformational changes, and VWF-platelet interaction in deep suspensions. Labeled VWF, platelets, and VWF-platelet strands are suspended in deep cuvettes, illuminated, and imaged with a high-sensitivity EM-CCD camera, allowing detection using an exposure time of 1 ms. In-house postprocessing algorithms identify and track the moving signals. Recombinant VWF-eGFP (rVWF-eGFP) and VWF labeled with an FITC-conjugated polyclonal antibody are employed. Anti-P-Selectin FITC-conjugated antibodies and the calcium-sensitive probe Indo-1 are used to detect activated platelets. A positive correlation between the mean number of platelets detected per image and the percentage of activated platelets determined through flow cytometry is obtained, validating the technique. An increase in the number of rVWF-eGFP signals upon exposure to shear stress demonstrates the technique's ability to detect breakup of self-aggregates. VWF globular and unfolded conformations and self-aggregation are also observed. The ability to track the size and shape of VWF-platelet strands in space and time provides means to detect pro- and antithrombotic processes.
Assessment of Sentinel Node Biopsies With Full-Field Optical Coherence Tomography.
Grieve, Kate; Mouslim, Karima; Assayag, Osnath; Dalimier, Eugénie; Harms, Fabrice; Bruhat, Alexis; Boccara, Claude; Antoine, Martine
2016-04-01
Current techniques for the intraoperative analysis of sentinel lymph nodes during breast cancer surgery present drawbacks such as time and tissue consumption. Full-field optical coherence tomography is a novel noninvasive, high-resolution, fast imaging technique. This study investigated the use of full-field optical coherence tomography as an alternative technique for the intraoperative analysis of sentinel lymph nodes. Seventy-one axillary lymph nodes from 38 patients at Tenon Hospital were imaged minutes after excision with full-field optical coherence tomography in the pathology laboratory, before being handled for histological analysis. A pathologist performed a blind diagnosis (benign/malignant), based on the full-field optical coherence tomography images alone, which resulted in a sensitivity of 92% and a specificity of 83% (n = 65 samples). Regular feedback was given during the blind diagnosis, with thorough analysis of the images, such that features of normal and suspect nodes were identified in the images and compared with histology. A nonmedically trained imaging expert also performed a blind diagnosis aided by the reading criteria defined by the pathologist, which resulted in 85% sensitivity and 90% specificity (n = 71 samples). The number of false positives of the pathologist was reduced by 3 in a second blind reading a few months later. These results indicate that following adequate training, full-field optical coherence tomography can be an effective noninvasive diagnostic tool for extemporaneous sentinel node biopsy qualification. © The Author(s) 2015.
Roy, S; Gruenbaum, S M; Skinner, J L
2014-11-14
Understanding the structure of water near cell membranes is crucial for characterizing water-mediated events such as molecular transport. To obtain structural information of water near a membrane, it is useful to have a surface-selective technique that can probe only interfacial water molecules. One such technique is vibrational sum-frequency generation (VSFG) spectroscopy. As model systems for studying membrane headgroup/water interactions, in this paper we consider lipid and surfactant monolayers on water. We adopt a theoretical approach combining molecular dynamics simulations and phase-sensitive VSFG to investigate water structure near these interfaces. Our simulated spectra are in qualitative agreement with experiments and reveal orientational ordering of interfacial water molecules near cationic, anionic, and zwitterionic interfaces. OH bonds of water molecules point toward an anionic interface leading to a positive VSFG peak, whereas the water hydrogen atoms point away from a cationic interface leading to a negative VSFG peak. Coexistence of these two interfacial water species is observed near interfaces between water and mixtures of cationic and anionic lipids, as indicated by the presence of both negative and positive peaks in their VSFG spectra. In the case of a zwitterionic interface, OH orientation is toward the interface on the average, resulting in a positive VSFG peak.
Chen, Li; Mossa-Basha, Mahmud; Balu, Niranjan; Canton, Gador; Sun, Jie; Pimentel, Kristi; Hatsukami, Thomas S; Hwang, Jenq-Neng; Yuan, Chun
2018-06-01
To develop a quantitative intracranial artery measurement technique to extract comprehensive artery features from time-of-flight MR angiography (MRA). By semiautomatically tracing arteries based on an open-curve active contour model in a graphical user interface, 12 basic morphometric features and 16 basic intensity features for each artery were identified. Arteries were then classified as one of 24 types using prediction from a probability model. Based on the anatomical structures, features were integrated within 34 vascular groups for regional features of vascular trees. Eight 3D MRA acquisitions with intracranial atherosclerosis were assessed to validate this technique. Arterial tracings were validated by an experienced neuroradiologist who checked agreement at bifurcation and stenosis locations. This technique achieved 94% sensitivity and 85% positive predictive values (PPV) for bifurcations, and 85% sensitivity and PPV for stenosis. Up to 1,456 features, such as length, volume, and averaged signal intensity for each artery, as well as vascular group in each of the MRA images, could be extracted to comprehensively reflect characteristics, distribution, and connectivity of arteries. Length for the M1 segment of the middle cerebral artery extracted by this technique was compared with reviewer-measured results, and the intraclass correlation coefficient was 0.97. A semiautomated quantitative method to trace, label, and measure intracranial arteries from 3D-MRA was developed and validated. This technique can be used to facilitate quantitative intracranial vascular research, such as studying cerebrovascular adaptation to aging and disease conditions. Magn Reson Med 79:3229-3238, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Computer-assisted expert case definition in electronic health records.
Walker, Alexander M; Zhou, Xiaofeng; Ananthakrishnan, Ashwin N; Weiss, Lisa S; Shen, Rongjun; Sobel, Rachel E; Bate, Andrew; Reynolds, Robert F
2016-02-01
To describe how computer-assisted presentation of case data can lead experts to infer machine-implementable rules for case definition in electronic health records. As an illustration the technique has been applied to obtain a definition of acute liver dysfunction (ALD) in persons with inflammatory bowel disease (IBD). The technique consists of repeatedly sampling new batches of case candidates from an enriched pool of persons meeting presumed minimal inclusion criteria, classifying the candidates by a machine-implementable candidate rule and by a human expert, and then updating the rule so that it captures new distinctions introduced by the expert. Iteration continues until an update results in an acceptably small number of changes to form a final case definition. The technique was applied to structured data and terms derived by natural language processing from text records in 29,336 adults with IBD. Over three rounds the technique led to rules with increasing predictive value, as the experts identified exceptions, and increasing sensitivity, as the experts identified missing inclusion criteria. In the final rule inclusion and exclusion terms were often keyed to an ALD onset date. When compared against clinical review in an independent test round, the derived final case definition had a sensitivity of 92% and a positive predictive value of 79%. An iterative technique of machine-supported expert review can yield a case definition that accommodates available data, incorporates pre-existing medical knowledge, is transparent and is open to continuous improvement. The expert updates to rules may be informative in themselves. In this limited setting, the final case definition for ALD performed better than previous, published attempts using expert definitions. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Jorgenson, D B; Haynor, D R; Bardy, G H; Kim, Y
1995-02-01
A method for constructing and solving detailed patient-specific 3-D finite element models of the human thorax is presented for use in defibrillation studies. The method utilizes the patient's own X-ray CT scan and a simplified meshing scheme to quickly and efficiently generate a model typically composed of approximately 400,000 elements. A parameter sensitivity study on one human thorax model to examine the effects of variation in assigned tissue resistivity values, level of anatomical detail included in the model, and number of CT slices used to produce the model is presented. Of the seven tissue types examined, the average left ventricular (LV) myocardial voltage gradient was most sensitive to the values of myocardial and blood resistivity. Incorrectly simplifying the model, for example modeling the heart as a homogeneous structure by ignoring the blood in the chambers, caused the average LV myocardial voltage gradient to increase by 12%. The sensitivity of the model to variations in electrode size and position was also examined. Small changes (< 2.0 cm) in electrode position caused average LV myocardial voltage gradient values to increase by up to 12%. We conclude that patient-specific 3-D finite element modeling of human thoracic electric fields is feasible and may reduce the empiric approach to insertion of implantable defibrillators and improve transthoracic defibrillation techniques.
Ullah, Irfan; Javaid, Arshad; Masud, Haleema; Ali, Mazhar; Basit, Anila; Ahmad, Waqas; Younis, Faisal; Yasmin, Rehana; Khan, Afsar; Jabbar, Abdul; Husain, Masroor; Butt, Zahid Ahmad
2017-04-01
Tuberculosis (TB) is a serious public health problem in developing countries such as Pakistan. Rapid diagnosis of TB and detection of drug resistance are very important for timely and appropriate management of multidrug-resistant TB (MDR-TB). The purpose of this study was to determine the diagnostic efficacy of the Xpert MTB/RIF assay for rapid diagnosis of TB and detection of rifampicin (RIF) resistance in extrapulmonary and smear-negative pulmonary TB suspects. A total of 98 bronchoalveolar lavage fluid (BALF) and 168 extrapulmonary specimens were processed by Xpert MTB/RIF. Culture results are considered as the gold standard for diagnosis of TB, and drug susceptibility testing for detection of RIF resistance. Diagnostic efficacy was measured in terms of sensitivity, specificity and positive and negative predictive values. The Xpert MTB/RIF assay detected 40 (40.8 %) of 98 BALF of presumptive pulmonary TB and 60 (35.7 %) of 168 extrapulmonary specimens. Sensitivity and specificity of the Xpert MTB/RIF assay for detection of TB was 86 and 88.4 %, respectively. The positive predictive value was 71.5 % while negative predictive value was 95.1 %. The Xpert MTB/RIF assay is a rapid and simple technique with high sensitivity and specificity for diagnosing TB and detecting drug resistance in extrapulmonary and smear-negative TB cases.
Johnson, Curtis L; Schwarb, Hillary; Horecka, Kevin M; McGarry, Matthew D J; Hillman, Charles H; Kramer, Arthur F; Cohen, Neal J; Barbey, Aron K
2018-05-01
Brain tissue mechanical properties, measured in vivo with magnetic resonance elastography (MRE), have proven to be sensitive metrics of neural tissue integrity. Recently, our group has reported on the positive relationship between viscoelasticity of the hippocampus and performance on a relational memory task in healthy young adults, which highlighted the potential of sensitive MRE measures for studying brain health and its relation to cognitive function; however, structure-function relationships outside of the hippocampus have not yet been explored. In this study, we examined the relationships between viscoelasticity of both the hippocampus and the orbitofrontal cortex and performance on behavioral assessments of relational memory and fluid intelligence. In a sample of healthy, young adults (N = 53), there was a significant, positive relationship between orbitofrontal cortex viscoelasticity and fluid intelligence performance (r = 0.42; p = .002). This finding is consistent with the previously reported relationship between hippocampal viscoelasticity and relational memory performance (r = 0.41; p = .002). Further, a significant double dissociation between the orbitofrontal-fluid intelligence relationship and the hippocampal-relational memory relationship was observed. These data support the specificity of regional brain MRE measures in support of separable cognitive functions. This report of a structure-function relationship observed with MRE beyond the hippocampus suggests a future role for MRE as a sensitive neuroimaging technique for brain mapping. Copyright © 2018 Elsevier Inc. All rights reserved.
Impacts of simultaneous multislice acquisition on sensitivity and specificity in fMRI.
Risk, Benjamin B; Kociuba, Mary C; Rowe, Daniel B
2018-05-15
Simultaneous multislice (SMS) imaging can be used to decrease the time between acquisition of fMRI volumes, which can increase sensitivity by facilitating the removal of higher-frequency artifacts and boosting effective sample size. The technique requires an additional processing step in which the slices are separated, or unaliased, to recover the whole brain volume. However, this may result in signal "leakage" between aliased locations, i.e., slice "leakage," and lead to spurious activation (decreased specificity). SMS can also lead to noise amplification, which can reduce the benefits of decreased repetition time. In this study, we evaluate the original slice-GRAPPA (no leak block) reconstruction algorithm and acceleration factor (AF = 8) used in the fMRI data in the young adult Human Connectome Project (HCP). We also evaluate split slice-GRAPPA (leak block), which can reduce slice leakage. We use simulations to disentangle higher test statistics into true positives (sensitivity) and false positives (decreased specificity). Slice leakage was greatly decreased by split slice-GRAPPA. Noise amplification was decreased by using moderate acceleration factors (AF = 4). We examined slice leakage in unprocessed fMRI motor task data from the HCP. When data were smoothed, we found evidence of slice leakage in some, but not all, subjects. We also found evidence of SMS noise amplification in unprocessed task and processed resting-state HCP data. Copyright © 2018 Elsevier Inc. All rights reserved.
Automation of a flocculation test for syphilis on Groupamatic equipment.
Garretta, M; Paris-Hamelin, A; Gener, J; Muller, A; Matte, C; Vaisman, A
1975-01-01
A flocculation reaction employing a cardiolipid antigen was used for syphilis screening on Groupamatic equipment in parallel with conventional screening reactions: Kolmer CF, RPCF, Kahn, Kline, and RPR. The positive samples were confirmed by FTA-200, FTA-ABS, TPI, and in some cases by TPHA. There were 5,212 known samples which had already been tested by all methods and of which 1,648 were positive, and 58,636 screened samples including 65 positives. Half of the samples in the first series were taken without anticoagulant; the remainder were collected in potassium EDTA. The percentage of false positives with the Groupamatic was about 1-4 per cent. The percentage of false negatives among positve (greater than or equal+) samples varied from 0-18 to 1-3 per cent.; on the other hand the sensitivity was less good for samples giving doubtful and/or dissociated reactions in conventional screening reactions. The specificity and sensitivity of this technique are acceptable for a blood transfusion centre. The reproducibility is excellent and the automatic reading of results accurate. Additional advantages are rapidity (340 samples processed per hour); simultaneous performance of eleven other immunohaematological reactions; no contamination between samples; automatic reading, interpretation, and print-out of results; and saving of time because samples are not filed sequentially and are automatically identified when the results are obtained. Although the importance of syphilis in blood transfusion seems small, estimates of the risk are difficult and further investigations are planned. Images PMID:1098731
Ross, Nicholas E; Pritchard, Charles J; Rubin, David M; Dusé, Adriano G
2006-05-01
Malaria is a serious global health problem, and rapid, accurate diagnosis is required to control the disease. An image processing algorithm to automate the diagnosis of malaria on thin blood smears is developed. The image classification system is designed to positively identify malaria parasites present in thin blood smears, and differentiate the species of malaria. Images are acquired using a charge-coupled device camera connected to a light microscope. Morphological and novel threshold selection techniques are used to identify erythrocytes (red blood cells) and possible parasites present on microscopic slides. Image features based on colour, texture and the geometry of the cells and parasites are generated, as well as features that make use of a priori knowledge of the classification problem and mimic features used by human technicians. A two-stage tree classifier using backpropogation feedforward neural networks distinguishes between true and false positives, and then diagnoses the species (Plasmodium falciparum, P. vivax, P. ovale or P. malariae) of the infection. Malaria samples obtained from the Department of Clinical Microbiology and Infectious Diseases at the University of the Witwatersrand Medical School are used for training and testing of the system. Infected erythrocytes are positively identified with a sensitivity of 85% and a positive predictive value (PPV) of 81%, which makes the method highly sensitive at diagnosing a complete sample provided many views are analysed. Species were correctly determined for 11 out of 15 samples.
Simplified PCR for detection of Haemophilus ducreyi and diagnosis of chancroid.
West, B; Wilson, S M; Changalucha, J; Patel, S; Mayaud, P; Ballard, R C; Mabey, D
1995-01-01
A simplified PCR was developed for detection of Haemophilus ducreyi in samples from chancroid patients. The strategy included a straightforward chloroform extraction sample preparation method, a one-tube nested PCR to minimize contamination risks, and a colorimetric method for detection of products. Primers were designed from published nucleotide sequences of the 16S rRNA gene of H. ducreyi, with longer outer primers for annealing at a higher temperature and shorter inner primers labelled with biotin and digoxigenin for binding with avidin and colorimetric detection. The PCR technique detected all 35 strains of H. ducreyi tested, from four different geographical regions, and was negative for other, related strains of bacteria and for the common contaminating bacteria tested. Of 25 samples from H. ducreyi culture-positive chancroid patients, 24 were PCR positive and 1 produced a weak reaction. Of 83 samples from clinical cases of chancroid in the Republic of South Africa, 69 were PCR positive. The sensitivity of PCR compared with that of clinical diagnosis was 83%. All 50 negative control samples were negative. Encouraging results were also obtained with a consecutive series of 25 genital ulcer patients in Tanzania, of whom 9 were PCR positive. The adaptations of this simplified PCR strategy, at the sensitivity and specificity levels obtained, mean it will be useful for detection of H. ducreyi in areas where the organism is endemic, particularly where testing by culture is difficult or impossible. PMID:7540625
Roth, Gary A; Sosa Peña, Maria del Pilar; Neu-Baker, Nicole M; Tahiliani, Sahil; Brenner, Sara A
2015-12-08
Nanomaterials are increasingly prevalent throughout industry, manufacturing, and biomedical research. The need for tools and techniques that aid in the identification, localization, and characterization of nanoscale materials in biological samples is on the rise. Currently available methods, such as electron microscopy, tend to be resource-intensive, making their use prohibitive for much of the research community. Enhanced darkfield microscopy complemented with a hyperspectral imaging system may provide a solution to this bottleneck by enabling rapid and less expensive characterization of nanoparticles in histological samples. This method allows for high-contrast nanoscale imaging as well as nanomaterial identification. For this technique, histological tissue samples are prepared as they would be for light-based microscopy. First, positive control samples are analyzed to generate the reference spectra that will enable the detection of a material of interest in the sample. Negative controls without the material of interest are also analyzed in order to improve specificity (reduce false positives). Samples can then be imaged and analyzed using methods and software for hyperspectral microscopy or matched against these reference spectra in order to provide maps of the location of materials of interest in a sample. The technique is particularly well-suited for materials with highly unique reflectance spectra, such as noble metals, but is also applicable to other materials, such as semi-metallic oxides. This technique provides information that is difficult to acquire from histological samples without the use of electron microscopy techniques, which may provide higher sensitivity and resolution, but are vastly more resource-intensive and time-consuming than light microscopy.
Ostoa-Saloma, P; Garza-Ramos, G; Ramírez, J; Becker, I; Berzunza, M; Landa, A; Gómez-Puyou, A; Tuena de Gómez-Puyou, M; Pérez-Montfort, R
1997-03-15
The gene that encodes for triosephosphate isomerase from Trypanosoma cruzi was cloned and sequenced. In T. cruzi, there is only one gene for triosephosphate isomerase. The enzyme has an identity of 72% and 68% with triosephosphate isomerase from Trypanosoma brucei and Leishmania mexicana, respectively. The active site residues are conserved: out of the 32 residues that conform the interface of dimeric triosephosphate isomerase from T. brucei, 29 are conserved in the T. cruzi enzyme. The enzyme was expressed in Escherichia coli and purified to homogeneity. Data from electrophoretic analysis under denaturing techniques and filtration techniques showed that triosephosphate isomerase from T. cruzi is a homodimer. Some of its structural and kinetic features were determined and compared to those of the purified enzymes from T. brucei and L. mexicana. Its circular dichroism spectrum was almost identical to that of triosephosphate isomerase from T. brucei. Its kinetic properties and pH optima were similar to those of T. brucei and L. mexicana, although the latter exhibited a higher Vmax with glyceraldehyde 3-phosphate as substrate. The sensitivity of the three enzymes to the sulfhydryl reagent methylmethane thiosulfonate (MeSO2-SMe) was determined; the sensitivity of the T. cruzi enzyme was about 40 times and 200 times higher than that of the enzymes from T. brucei and L. mexicana, respectively. Triosephosphate isomerase from T. cruzi and L. mexicana have the three cysteine residues that exist in the T. brucei enzyme (positions 14, 39, 126, using the numbering of the T. brucei enzyme); however, they also have an additional residue (position 117). These data suggest that regardless of the high identity of the three trypanosomatid enzymes, there are structural differences in the disposition of their cysteine residues that account for their different sensitivity to the sulfhydryl reagent. The disposition of the cysteine in triosephosphate isomerase from T. cruzi appears to make it unique for inhibition by modification of its cysteine.
Acousto-optical Transducer with Surface Plasmons
NASA Astrophysics Data System (ADS)
Kolomenskii, A. A.; Surovic, E.; Schuessler, H. A.
2018-04-01
The surface plasmon resonance (SPR) is a sensitive technique for the detection of changes in dielectric parameters in close proximity to a metal film supporting surface plasmon waves. Here we study the application of the SPR effect to an efficient conversion of an acoustic signal into an optical one. Such a transducer potentially has a large bandwidth and good sensitivity. When an acoustic wave is incident onto a receiving plate positioned within the penetration depth of the surface plasmons, it creates displacements of the surface of the plate and, thus, modulates the dielectric properties in the proximity of the gold film. This modulation, in turn, modifies the light reflection under surface plasmon resonance conditions. We simulate characteristics of this acousto-optical transducer with surface plasmons and provide sets of parameters at the optical wavelength of 800 nm and 633 nm for its realization.
Molecular imaging with radionuclides, a powerful technique for studying biological processes in vivo
NASA Astrophysics Data System (ADS)
Cisbani, E.; Cusanno, F.; Garibaldi, F.; Magliozzi, M. L.; Majewski, S.; Torrioli, S.; Tsui, B. M. W.
2007-02-01
Our team is carrying on a systematic study devoted to the design of a SPECT detector with submillimeter resolution and adequate sensitivity (1 cps/kBq). Such system will be used for functional imaging of biological processes at molecular level in small animal. The system requirements have been defined by two relevant applications: study of atherosclerotic plaques characterization and stem cells diffusion and homing. In order to minimize costs and implementation time, the gamma detector will be based—as much as possible—on conventional components: scintillator crystal and position sensitive PhotoMultipliers read by individual channel electronics. A coded aperture collimator should be adapted to maximize the efficiency. The optimal selection of the detector components is investigated by systematic use of Monte-Carlo simulations (and laboratory validation tests); and finally preliminary results are presented and discussed here.
Veh, R W
1991-01-02
For double tracing experiments, wheat germ agglutinin (WGA) molecules labeled with two different haptens are desirable. In the present report the suitability of digoxigenylated WGA (DIG-WGA) for retrograde tracing was investigated. For this purpose the new tracer was pressure injected into rat brains and the transported DIG-WGA visualized via its digoxigenyl group with an alkaline phosphatase linked anti DIG antibody in permanently stained sections of high quality. With fixatives containing 2.5% glutaraldehyde only few positive cells were found. However, at milder fixation conditions (4% paraformaldehyde, 0.05% glutaraldehyde 0.2% picric acid, 30 min) retrogradely labeled cells were detected with a sensitivity comparable to tetramethylbenzidine protocols for conventional WGA-HRP (horseradish peroxidase) tracing. Preliminary experiments suggest excellent suitability for double labeling.
Gagliardi, J A; Chung, E M; Chandnani, V P; Kesling, K L; Christensen, K P; Null, R N; Radvany, M G; Hansen, M F
1994-09-01
Chondromalacia patellae is a condition characterized by softening, fraying, and ulceration of patellar articular cartilage. We compare the sensitivity, specificity, and accuracy of conventional MR imaging, MR arthrography, and CT arthrography in detecting and staging this abnormality. Twenty-seven patients with pain in the anterior part of the knee were prospectively examined with MR imaging, including T1-weighted (650/16), proton density-weighted (2000/20), T2-weighted (2000/80), and spoiled two-dimensional gradient-recalled acquisition in the steady state (SPGR/)/35 degrees (51/10) with fat saturation pulse sequences. All were also examined with T1-weighted MR imaging after intraarticular injection of dilute gadopentetate dimeglumine and with double-contrast CT arthrography. Each imaging technique was evaluated independently by two observers, who reached a consensus interpretation. The signal characteristics of cartilage on MR images and contour abnormalities noted with all imaging techniques were evaluated and graded according to a modification of the classification of Shahriaree. Twenty-six of the 54 facets examined had chondromalacia shown by arthroscopy, which was used as the standard of reference. The sensitivity, specificity, and accuracy of each imaging technique in the diagnosis of each stage of chondromalacia patellae were determined and compared by using the McNemar two-tailed analysis. Arthroscopy showed that 28 facets were normal. Grade 1 chondromalacia patellae was diagnosed only with MR and CT arthrography in two (29%) of seven facets. Intermediate (grade 2 or 3) chondromalacia patellae was detected in two (13%) of 15 facets with T1-weighted and SPGR MR imaging, in three (20%) of 15 facets with proton density-weighted MR imaging, in seven (47%) of 15 facets with T2-weighted MR imaging, in 11 (73%) of 15 facets with CT arthrography, and in 12 (80%) of 15 facets with MR arthrography. Grade 4 was detected in three (75%) of four facets with T1-, proton density-, and T2-weighted MR imaging, two (50%) of four facets with SPGR MR imaging, and four (100%) of four facets with MR and CT arthrography. Thus, all imaging techniques were insensitive to grade 1 lesions and highly sensitive to grade 4 lesions, so that no significant difference among the techniques could be shown. All imaging techniques studied had high specificity and accuracy in the detection and grading of chondromalacia patella; however, both MR arthrography and CT arthrography were more sensitive than T1-weighted, proton density-weighted, and SPGR with fat saturation MR imaging for showing intermediate grades of chondromalacia patellae. Although the arthrographic techniques were not significantly better than T2-weighted imaging, the number of false-positive diagnoses was greatest with T2-weighted MR imaging.
Poudel, A; Pandey, B D; Lekhak, B; Rijal, B; Sapkota, B R; Suzuki, Y
2009-01-01
Tuberculosis is a global health problem and the situation is worsening with newer incidences of drug resistance and HIV association. Diagnosis of tuberculosis can be done by many methods and test, culture of sputum being the ideal one. Nucleic acid amplification (NAA) assay are more time efficient one, that amplify and detect specific nucleic acid sequences allows rapid, sensitive and specific detection of M. tuberculosis in sputum samples. The present study intends to compile the clinical presentations of the pulmonary tuberculosis (PTB) patients and to evaluate the efficacy of in-house loop-mediated isothermal amplification (LAMP) in detecting Mycobacterium tuberculosis in sputum samples by comparing with microscopy and culture. Two hundred two sputum samples were collected from 202 patients at National Tuberculosis Center, Bhaktapur, Nepal. Complete clinical profiling, epidemiological data and record on BCG vaccination were noted and the samples were subjected for microscopy, culture and in-house LAMP with six primers specific for 16S RNA gene of Mycobacterium tuberculosis. Of the 176 cases of clinical profiling, productive cough was most common symptom in 147 (83.52%), followed by chest pain 136 (77.27%), fever 133 (75.56%) and haemoptysis 61 (34.66%). There was a statistically significant association between BCG vaccination and development of TB (chi(2)=5.33, P=0.02). Of 202 cases, 115 (56.93%) were chest X-ray positive, 101(50%) were direct smear-positive and 100 (49.51%) were culture positive. LAMP had a sensitivity of 97% and specificity of 94.12% while comparing with culture. In addition, its sensitivity and specificity were 91.09% and 89.11% respectively with reference to microscopy. As in our previous study, overall, the result of present study further confirms that the in-house LAMP is a simple, rapid, sensitive and specific DNA amplification technique for PTB diagnosis. Because of rapidity of microscopy and specificity of culture, in-house LAMP assay can be used as a very powerful and useful supplementary tool with complete clinical profiling of the patients for rapid diagnosis of TB in both AFB-positive and negative cases who are suspected as PTB in disease endemic country like Nepal.
[Secretion analysis of pathogenic bacteria culture in 115 rural chronic nasal-sinusitis patients].
Zhang, Xiaoyuan; Sun, Jingwu; Chu, Shu
2014-05-01
To investigate the bacteria distribution, drug bacterial sensitivity characteristics of the rural chronic rhinosinusitis (CRS). And to explore the effect of antibiotic on pathogenic bacteria culture. Choose nasal sinus secretions from 115 CRS patients living in rural areas. Aerobic bacteria culture, anaerobic bacteria culture and drug sensitive test were procedured for each sample. At the same time the use of antibiotics nearly 2 months and nearly 2 weeks were collected. Among one hundred and fifteen specimens, 17 kinds of germs were detected in 37 cases, the positive rate of aerobic bacteria was 32.17%. Staphylococcus aureus and epidermis staphylococcus aureus the most common type of aerobe in CRS patients at rural areas. There was negative result in the anaerobic bacteria culture of 17 maxillary sinus specimen. The cases of using antibiotics nearly 2 months was up to 90, accounting for 78.26%. Nearly 2 weeks, 73 cases, accounting for 63.48%. The chi-square analysis showed high bacterial culture rate, in chronic rhinosinusitis with nasal polyps (CRSwNP group), which revealed correlation between bacterial infection factors and nasal polyps formation. For CRS patients with positive result of bacterial culture, they were sensitive to ofloxacin, cefotaxime, organism, ciprofloxacin, magnitude cephalosporin, and were drug fast to penicillin G, ampicillin, erythromycin. No specific differences was found in the bacteria distribution of rural CRS. antibiotics abusage in rural CRS patients and the anaerobic bacteria culture techniques is the main factor resulting in low culture rate. Rational use of antimicrobial agents should be established on the basis of the bacterial culture and drug sensitive test.
Diagnosis of Bubonic Plague by PCR in Madagascar under Field Conditions
Rahalison, L.; Vololonirina, E.; Ratsitorahina, M.; Chanteau, S.
2000-01-01
The diagnostic value of a PCR assay that amplifies a 501-bp fragment of the Yersinia pestis caf1 gene has been determined in a reference laboratory with 218 bubo aspirates collected from patients with clinically suspected plague managed in a regional hospital in Madagascar. The culture of Y. pestis and the detection of the F1 antigen (Ag) by enzyme-linked immunosorbent assay (ELISA) were used as reference diagnostic methods. The sensitivity of PCR was 89% (57 of 64) for the Y. pestis-positive patients, and 80.7% (63 of 78) for the F1 Ag-positive patients. The specificity of PCR for the culture-, F1 Ag-, and antibody-negative patients (n = 105) was 100%. Because in Madagascar most patients with plague are managed and their clinical samples are collected in remote villages, the usefulness of PCR was evaluated for routine diagnostic use in the operational conditions of the control program. The sensitivity of PCR was 50% (25 of 50) relative to the results of culture and 35.2% (19 of 54) relative to the results of the F1 Ag immunocapture ELISA. The specificity of PCR under these conditions was 96%. In conclusion, the PCR method was found to be very specific but not as sensitive as culture or the F1 Ag detection method. The limitation in sensitivity may have been due to suboptimal field conditions and the small volumes of samples used for DNA extraction. This technique is not recommended as a routine diagnostic test for plague in Madagascar. PMID:10618097
Banal, Frédéric; Gandjbakhch, Frédérique; Foltz, Violaine; Goldcher, Alain; Etchepare, Fabien; Rozenberg, Sylvie; Koeger, Anne-Claude; Bourgeois, Pierre; Fautrel, Bruno
2009-08-01
To date, early diagnosis of stress fractures depends on magnetic resonance imaging (MRI) or bone scan scintigraphy, as radiographs are usually normal at onset of symptoms. These examinations are expensive or invasive, time-consuming, and poorly accessible. A recent report has shown the ability of ultrasonography (US) to detect early stress fractures. Our objective was to evaluate sensitivity and specificity of US versus dedicated MRI (0.2 Tesla), taken as the gold standard, in early diagnosis of metatarsal bone stress fractures. A case-control study from November 2006 to December 2007 was performed. All consecutive patients with mechanical pain and swelling of the metatarsal region for less than 3 months and with normal radiographs were included. US and dedicated MRI examinations of the metatarsal bones were performed the same day by experienced rheumatologists with expertise in US and MRI. Reading was undertaken blind to the clinical assessment and MRI/US results. Forty-one feet were analyzed on US and dedicated MRI from 37 patients (28 women, 9 men, mean age 52.7 +/- 14.1 yrs). MRI detected 13 fractures in 12 patients. Sensitivity of US was 83%, specificity 76%, positive predictive value 59%, and negative predictive value 92%. Positive likehood ratio was 3.45, negative likehood ratio 0.22. In cases of normal radiographs, US is indicated in the diagnosis of metatarsal bone stress fractures, as it is a low cost, noninvasive, rapid, and easy technique with good sensitivity and specificity. From these data, we propose a new imaging algorithm including US.
Zhang, Rong; He, Yi-feng; Chen, Mo; Chen, Chun-mei; Zhu, Qiu-jing; Lu, Huan; Wei, Zhen-hong; Li, Fang; Zhang, Xiao-xin; Xu, Cong-jian; Yu, Long
2014-10-02
Cervical lesions caused by integrated human papillomavirus (HPV) infection are highly dangerous because they can quickly develop into invasive cancers. However, clinicians are currently hampered by the lack of a quick, convenient and precise technique to detect integrated/mixed infections of various genotypes of HPVs in the cervix. This study aimed to develop a practical tool to determine the physical status of different HPVs and evaluate its clinical significance. The target population comprised 1162 women with an HPV infection history of > six months and an abnormal cervical cytological finding. The multiple E1-L1/E6E7 ratio analysis, a novel technique, was developed based on determining the ratios of E1/E6E7, E2/E6E7, E4E5/E6E7, L2/E6E7 and L1/E6E7 within the viral genome. Any imbalanced ratios indicate integration. Its diagnostic and predictive performances were compared with those of E2/E6E7 ratio analysis. The detection accuracy of both techniques was evaluated using the gold-standard technique "detection of integrated papillomavirus sequences" (DIPS). To realize a multigenotypic detection goal, a primer and probe library was established. The integration rate of a particular genotype of HPV was correlated with its tumorigenic potential and women with higher lesion grades often carried lower viral loads. The E1-L1/E6E7 ratio analysis achieved 92.7% sensitivity and 99.0% specificity in detecting HPV integration, while the E2/E6E7 ratio analysis showed a much lower sensitivity (75.6%) and a similar specificity (99.3%). Interference due to episomal copies was observed in both techniques, leading to false-negative results. However, some positive results of E1-L1/E6E7 ratio analysis were missed by DIPS due to its stochastic detection nature. The E1-L1/E6E7 ratio analysis is more efficient than E2/E6E7 ratio analysis and DIPS in predicting precancerous/cancerous lesions, in which both positive predictive values (36.7%-82.3%) and negative predictive values (75.9%-100%) were highest (based on the results of three rounds of biopsies). The multiple E1-L1/E6E7 ratio analysis is more sensitive and predictive than E2/E6E7 ratio analysis as a triage test for detecting HPV integration. It can effectively narrow the range of candidates for colposcopic examination and cervical biopsy, thereby lowering the expense of cervical cancer prevention.
pH-Sensitive Interactions between Cellulose Nanocrystals and DOPC Liposomes.
Navon, Yotam; Radavidson, Harisoa; Putaux, Jean-Luc; Jean, Bruno; Heux, Laurent
2017-09-11
The interaction of 1,2 dioleolyl-sn-glycero-3-phosphatidylcholine (DOPC) vesicles with cellulose nanocrystals (CNCs) using several complementary techniques. Dynamic light scattering, zeta-potential, cryo-transmission electron microscopy and isothermal titration calorimetry (ITC) analyses confirmed the formation of pH-dependent CNC-liposome complexes. ITC was used to characterize the thermodynamic properties of this interaction. Positive values of enthalpy were found at pH lower than 5 where the charge sign of the constituents was opposite. The association was more pronounced at lower pH, as indicated by the higher values of association constant. We suggest that the positive enthalpy is derived from the release of counterions from the particle hydration shell during the association and that the charge of the vesicles plays a significant role in this interaction.
Relaxation time estimation in surface NMR
Grunewald, Elliot D.; Walsh, David O.
2017-03-21
NMR relaxation time estimation methods and corresponding apparatus generate two or more alternating current transmit pulses with arbitrary amplitudes, time delays, and relative phases; apply a surface NMR acquisition scheme in which initial preparatory pulses, the properties of which may be fixed across a set of multiple acquisition sequence, are transmitted at the start of each acquisition sequence and are followed by one or more depth sensitive pulses, the pulse moments of which are varied across the set of multiple acquisition sequences; and apply processing techniques in which recorded NMR response data are used to estimate NMR properties and the relaxation times T.sub.1 and T.sub.2* as a function of position as well as one-dimensional and two-dimension distributions of T.sub.1 versus T.sub.2* as a function of subsurface position.
Variations in measured performance of CAD schemes due to database composition and scoring protocol
NASA Astrophysics Data System (ADS)
Nishikawa, Robert M.; Yarusso, Laura M.
1998-06-01
There is now a large effort towards developing computer- aided diagnosis (CAD) techniques. It is important to be able to compare performance of different approaches to be able to determine which ones are the most efficacious. There are currently a number of barriers preventing meaningful (statistical) comparisons, two of which are discussed in this paper: database composition and scoring protocol. We have examined how the choice of cases used to test a CAD scheme can affect its performance. We found that our computer scheme varied between a sensitivity of 100% to 77%, at a false-positive rate of 1.0 per image, with only 100% change in the composition of the database. To evaluate the performance of a CAD scheme the output of the computer must be graded. There are a number of different criteria that are being used by different investigators. We have found that for the same set of detection results, the measured sensitivity can be between 40 - 90% depending on the scoring methodology. Clearly consensus must be reached on these two issues in order for the field to make rapid progress. As it stands now, it is not possible to make meaningful comparisons of different techniques.
Optimized Beam Sculpting with Generalized Fringe-rate Filters
NASA Astrophysics Data System (ADS)
Parsons, Aaron R.; Liu, Adrian; Ali, Zaki S.; Cheng, Carina
2016-03-01
We generalize the technique of fringe-rate filtering, whereby visibilities measured by a radio interferometer are re-weighted according to their temporal variation. As the Earth rotates, radio sources traverse through an interferometer’s fringe pattern at rates that depend on their position on the sky. Capitalizing on this geometric interpretation of fringe rates, we employ time-domain convolution kernels to enact fringe-rate filters that sculpt the effective primary beam of antennas in an interferometer. As we show, beam sculpting through fringe-rate filtering can be used to optimize measurements for a variety of applications, including mapmaking, minimizing polarization leakage, suppressing instrumental systematics, and enhancing the sensitivity of power-spectrum measurements. We show that fringe-rate filtering arises naturally in minimum variance treatments of many of these problems, enabling optimal visibility-based approaches to analyses of interferometric data that avoid systematics potentially introduced by traditional approaches such as imaging. Our techniques have recently been demonstrated in Ali et al., where new upper limits were placed on the 21 {cm} power spectrum from reionization, showcasing the ability of fringe-rate filtering to successfully boost sensitivity and reduce the impact of systematics in deep observations.
A Survey of Shape Parameterization Techniques
NASA Technical Reports Server (NTRS)
Samareh, Jamshid A.
1999-01-01
This paper provides a survey of shape parameterization techniques for multidisciplinary optimization and highlights some emerging ideas. The survey focuses on the suitability of available techniques for complex configurations, with suitability criteria based on the efficiency, effectiveness, ease of implementation, and availability of analytical sensitivities for geometry and grids. The paper also contains a section on field grid regeneration, grid deformation, and sensitivity analysis techniques.
NASA Astrophysics Data System (ADS)
Kumar, Mukesh; Ojha, A.; Garg, A. D.; Puntambekar, T. A.; Senecha, V. K.
2017-02-01
According to the quasi electrostatic model of linear response capacitive beam position monitor (BPM), the position sensitivity of the device depends only on the aperture of the device and it is independent of processing frequency and load impedance. In practice, however, due to the inter-electrode capacitive coupling (cross talk), the actual position sensitivity of the device decreases with increasing frequency and load impedance. We have taken into account the inter-electrode capacitance to derive and propose a new analytical expression for the position sensitivity as a function of frequency and load impedance. The sensitivity of a linear response shoe-box type BPM has been obtained through simulation using CST Studio Suite to verify and confirm the validity of the new analytical equation. Good agreement between the simulation results and the new analytical expression suggest that this method can be exploited for proper designing of BPM.
Valero, María Adela; Periago, María Victoria; Pérez-Crespo, Ignacio; Angles, René; Villegas, Fidel; Aguirre, Carlos; Strauss, Wilma; Espinoza, José R.; Herrera, Patricia; Terashima, Angelica; Tamayo, Hugo; Engels, Dirk; Gabrielli, Albis Francesco; Mas-Coma, Santiago
2012-01-01
Background Emergence of human fascioliasis prompted a worldwide control initiative including a pilot study in a few countries. Two hyperendemic areas were chosen: Huacullani, Northern Altiplano, Bolivia, representing the Altiplanic transmission pattern with high prevalences and intensities; Cajamarca valley, Peru, representing the valley pattern with high prevalences but low intensities. Coprological sample collection, transport and study procedures were analyzed to improve individual diagnosis and subsequent treatments and surveillance activities. Therefore, a coproantigen-detection technique (MM3-COPRO ELISA) was evaluated, using classical techniques for egg detection for comparison. Methodology and Findings A total of 436 and 362 stool samples from schoolchildren of Huacullani and Cajamarca, respectively, were used. Positive samples from Huacullani were 24.77% using the MM3-COPRO technique, and 21.56% using Kato-Katz. Positive samples from Cajamarca were 11.05% using MM3-COPRO, and 5.24% using rapid sedimentation and Kato-Katz. In Huacullani, using Kato-Katz as gold standard, sensitivity and specificity were 94.68% and 98.48%, respectively, and using Kato-Katz and COPRO-ELISA test together, they were 95.68% and 100%. In Cajamarca, using rapid sedimentation and Kato-Katz together, results were 94.73% and 93.58%, and using rapid sedimentation, Kato-Katz and copro-ELISA together, they were 97.56% and 100%, respectively. There was no correlation between coproantigen detection by optical density (OD) and infection intensity by eggs per gram of feces (epg) in Cajamarca low burden cases (<400 epg), nor in Huacullani high burden cases (≥400 epg), although there was in Huacullani low burden cases (<400 epg). Six cases of egg emission appeared negative by MM3-COPRO, including one with a high egg count (1248 epg). Conclusions The coproantigen-detection test allows for high sensitivity and specificity, fast large mass screening capacity, detection in the chronic phase, early detection of treatment failure or reinfection in post-treated subjects, and usefulness in surveillance programs. However, this technique falls short when evaluating the fluke burden on its own. PMID:23029575
Mumba Ngoyi, Dieudonné; Ali Ekangu, Rosine; Mumvemba Kodi, Marie France; Pyana, Patient Pati; Balharbi, Fatima; Decq, Mélanie; Kande Betu, Victor; Van der Veken, Wim; Sese, Claude; Menten, Joris; Büscher, Philippe; Lejon, Veerle
2014-06-01
Recently, improvements have been made to diagnostics for gambiense sleeping sickness control but their performance remains poorly documented and may depend on specimen processing prior to examination. In a prospective study in the Democratic Republic of the Congo, we compared the diagnostic performance of several parasite detection techniques, immune trypanolysis and of m18S PCR on whole blood stored in a stabilisation buffer or dried on filter paper. Individuals with CATT whole blood (WB) titer ≥1∶4 or with clinical signs indicative for sleeping sickness were examined for presence of trypanosomes in lymph node aspirate (LNA) and/or in blood. Blood was examined with Capillary Centrifugation Technique (CTC), mini-Anion Exchange Centrifugation Technique (mAECT) and mAECT on buffy coat (BC). PCR was performed on whole blood (i) stored in guanidine hydrochloride EDTA (GE) stabilisation buffer and (ii) dried on filter paper, and repeatability and reproducibility were assessed. Immune trypanolysis (TL) was performed on plasma. A total of 237 persons were included. Among 143 parasitologically confirmed cases, 85.3% had a CATT-WB titre of ≥1/8, 39.2% were positive in LNA, 47.5% in CTC, 80.4% in mAECT-WB, 90.9% in mAECT-BC, 95.1% in TL and up to 89.5% in PCR on GE-stabilised blood. PCR on GE-stabilised blood showed highest repeatability (87.8%) and inter-laboratory reproducibility (86.9%). Of the 94 non-confirmed suspects, respectively 39.4% and 23.4% were TL or PCR positive. Suboptimal specificity of PCR and TL was also suggested by latent class analysis. The combination of LNA examination with mAECT-BC offered excellent diagnostic sensitivity. For PCR, storage of blood in stabilisation buffer is to be preferred over filter paper. TL as well as PCR are useful for remote diagnosis but are not more sensitive than mAECT-BC. For TL and PCR, the specificity, and thus usefulness for management of non-confirmed suspects remain to be determined.
Mumba Ngoyi, Dieudonné; Ali Ekangu, Rosine; Mumvemba Kodi, Marie France; Pyana, Patient Pati; Balharbi, Fatima; Decq, Mélanie; Kande Betu, Victor; Van der Veken, Wim; Sese, Claude; Menten, Joris; Büscher, Philippe; Lejon, Veerle
2014-01-01
Objectives Recently, improvements have been made to diagnostics for gambiense sleeping sickness control but their performance remains poorly documented and may depend on specimen processing prior to examination. In a prospective study in the Democratic Republic of the Congo, we compared the diagnostic performance of several parasite detection techniques, immune trypanolysis and of m18S PCR on whole blood stored in a stabilisation buffer or dried on filter paper. Methods Individuals with CATT whole blood (WB) titer ≥1∶4 or with clinical signs indicative for sleeping sickness were examined for presence of trypanosomes in lymph node aspirate (LNA) and/or in blood. Blood was examined with Capillary Centrifugation Technique (CTC), mini-Anion Exchange Centrifugation Technique (mAECT) and mAECT on buffy coat (BC). PCR was performed on whole blood (i) stored in guanidine hydrochloride EDTA (GE) stabilisation buffer and (ii) dried on filter paper, and repeatability and reproducibility were assessed. Immune trypanolysis (TL) was performed on plasma. Results A total of 237 persons were included. Among 143 parasitologically confirmed cases, 85.3% had a CATT-WB titre of ≥1/8, 39.2% were positive in LNA, 47.5% in CTC, 80.4% in mAECT-WB, 90.9% in mAECT-BC, 95.1% in TL and up to 89.5% in PCR on GE-stabilised blood. PCR on GE-stabilised blood showed highest repeatability (87.8%) and inter-laboratory reproducibility (86.9%). Of the 94 non-confirmed suspects, respectively 39.4% and 23.4% were TL or PCR positive. Suboptimal specificity of PCR and TL was also suggested by latent class analysis. Conclusion The combination of LNA examination with mAECT-BC offered excellent diagnostic sensitivity. For PCR, storage of blood in stabilisation buffer is to be preferred over filter paper. TL as well as PCR are useful for remote diagnosis but are not more sensitive than mAECT-BC. For TL and PCR, the specificity, and thus usefulness for management of non-confirmed suspects remain to be determined. PMID:24921941
Wang, J S; Li, J R
2018-04-07
Objective: The consistency and characteristics of 24-hour multichannel intraluminal impedance(MII)-pH monitoring and Dx-pH monitoring in the diagnosis of laryngopharyngeal reflux were investigated. Methods: Fifty-two patients with laryngopharyngeal reflux related symptoms or disease between March and October 2017 were included in this study.All patients were evaluated with 24-hour MII-pH monitoring and Dx-pH monitoring at the same time, recording each patient's number of positive laryngopharyngeal reflux events, time of acid clearance and Ryan index.The data was analysed with Mann-Whitney U test and consistency check. Results: Among all 52 patients, 16 patients(30.7%) had a positive MII-pH monitoring result and 14 patients(26.9%) had a positive Dx-pH monitoring results.The consistency of both technique for measurement of laryngopharyngeal reflux was general(κ=0.626). With MII-pH monitoring for reference, the sensitivity and specificity of 24-hour pH monitoring were 68.8% and 91.7%.A total of 62 positive reflux events(pH<4) were measured with MII-pH monitoring, and 50 positive reflux events(upright pH<5.5 or supine pH<5.0)were detected by Dx-pH monitoring.There were 44 positive reflux events detected by both techniques, the mean time of acid clearance was 22.8[13.5; 42.6] s. Correspondingly, 18 reflux events were measured by MII-pH monitoring without positive results of Dx-pH monitoring, the mean time of acid clearance was 5.2[3.5; 6.5] s. There was significant difference in the time of acid clearance between two groups( U =858.5, P <0.05). Conclusions: Dx-pH monitoring can accurately measure the change of pH value in airway, but exists the possibility of misdiagnosis especially when the time of acid clearance in laryngopharynx is short. MII-pH and Dx-pH monitoring can be complementary technique in the diagnosis of laryngopharyngeal reflux.
Ramos, Jose Tomas; Villar, Sonia; Bouza, Emilio; Bergon-Sendin, Elena; Perez Rivilla, Alfredo; Collados, Caridad Tapia; Andreu, Mariano; Reyes, Candelaria Santana; Campos-Herrero, María Isolina; de Heredia, Jon López; Herrera, María Cruz López; Alonso, Paloma Anguita; Pallás-Alonso, Carmen Rosa
2017-01-01
ABSTRACT An epidemiological, multicenter, noninterventional, observational case-control study was conducted to describe the performance of serum beta-d-glucan (BDG) and Candida PCR in blood, serum, and sterile samples for the diagnosis of invasive candidiasis (IC) in very-low-birth-weight (VLBW) preterm neonates and to compare these techniques with culture of samples from blood and other sterile sites. Seventeen centers participated in the study, and the number of episodes analyzed was 159. A total of 9 episodes of IC from 9 patients (7 confirmed and 2 probable) and 150 episodes of suspected sepsis from 117 controls were identified. The prevalence of IC was 5.7% (95% confidence interval [95% CI], 2.1 to 9.3). The mortality was significantly higher in episodes of IC (44.4%) than in the non-IC episodes (11.1%, P < 0.01). The sensitivity and specificity of the PCR performed on blood/serum samples were 87.5% and 81.6%, respectively. The sensitivity and specificity of the BDG results were lower (75.0% and 64.6%). For cases with negative culture results, the PCR and the BDG results were positive in 27 (17.4%) and 52 (33.5%) episodes, respectively. The presence of multiorgan failure, improvement with empirical antifungal therapy, thrombocytopenia, and Candida colonization were significantly associated (P < 0.01) with PCR or BDG positivity regardless of the results of the cultures. Serum BDG analysis and Candida PCR could be used as complementary diagnostic techniques to detect IC in VLBW neonates. PMID:28659321
Beyhan, Yunus Emre; Taş Cengiz, Zeynep
2017-08-23
Background/aim: This study included patients who had digestive system complaints between August 2015 and October 2015. The research was designed to compare conventional microscopy with an antigen detection ELISA kit and the TaqMan-based real-time PCR (RT-PCR) technique for detection of Giardia intestinalis in human stool specimens. Materials and methods: Samples were concentrated by formalin-ether sedimentation technique and microscopic examinations were carried out on wet mount slides. A commercially available ELISA kit (Giardia CELISA, Cellabs, Brookvale, Australia) was used for immunoassay. DNA was extracted from fecal samples of about 200 mg using the QIAamp Fast DNA Stool Mini Kit (QIAGEN, Hilden, Germany) and the LightCycler Nano system (Roche Diagnostics, Mannheim, Germany) was used for the TaqMan-based RT-PCR assay. Results: A total of 94 stool samples, 38 of them diagnosed positive (40.4%) and 56 of them diagnosed negative by microscopy, were selected for evaluation by antigen detection and molecular assays. The prevalence of G. intestinalis infection was found as 46.8% (n: 44) and 79.8% (n: 75) by ELISA and RT-PCR, respectively. RT-PCR revealed by far the highest positivity rate compared to the other two methods. The difference between these methods was found to be statistically significant (P < 0.05). In comparison to PCR, the sensitivity and specificity of microscopy and ELISA were 50.7% and 100% and 53.3% and 79%, respectively. Conclusion: RT-PCR seems to be much more sensitive and beneficial for rapid and accurate diagnosis of G. intestinalis in human stools.
Kohler, G.; Ruitenberg, E. J.
1974-01-01
Three methods employed in the diagnosis of trichinosis (trichinoscopy, digestion method, and immunofluorescence technique) were compared by laboratories in 5 countries of the European economic community. For this purpose, material from 32 pigs infected with 50, 150, 500, and 1 500 T. spiralis larvae was examined. With none of the three methods was it possible to detect with sufficient reliability a T. spiralis infection in pigs infected with 50 larvae. The digestion method and the immunofluorescence technique yielded more reliable results when the infection dose was 150 larvae or more. With trichinoscopy, reliable results were obtained in pigs infected with 500 and 1 500 larvae. With the digestion method and trichinoscopy, the onset of infections was detectable from 3 weeks post infection, the digestion method being more reliable; the immunofluorescence technique yielded positive results from approximately 4-6 weeks post infection. The immunofluorescence technique is applicable for epidemiological surveys. As a routine diagnostic procedure in the slaughterhouse, trichinoscopy and the digestion method are possible alternatives, the latter being more sensitive. PMID:4616776
Machine learning techniques for medical diagnosis of diabetes using iris images.
Samant, Piyush; Agarwal, Ravinder
2018-04-01
Complementary and alternative medicine techniques have shown their potential for the treatment and diagnosis of chronical diseases like diabetes, arthritis etc. On the same time digital image processing techniques for disease diagnosis is reliable and fastest growing field in biomedical. Proposed model is an attempt to evaluate diagnostic validity of an old complementary and alternative medicine technique, iridology for diagnosis of type-2 diabetes using soft computing methods. Investigation was performed over a close group of total 338 subjects (180 diabetic and 158 non-diabetic). Infra-red images of both the eyes were captured simultaneously. The region of interest from the iris image was cropped as zone corresponds to the position of pancreas organ according to the iridology chart. Statistical, texture and discrete wavelength transformation features were extracted from the region of interest. The results show best classification accuracy of 89.63% calculated from RF classifier. Maximum specificity and sensitivity were absorbed as 0.9687 and 0.988, respectively. Results have revealed the effectiveness and diagnostic significance of proposed model for non-invasive and automatic diabetes diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.
Improved detection of endoparasite DNA in soil sample PCR by the use of anti-inhibitory substances.
Krämer, F; Vollrath, T; Schnieder, T; Epe, C
2002-09-26
Although there have been numerous microbial examinations of soil for the presence of human pathogenic developmental parasite stages of Ancylostoma caninum and Toxocara canis, molecular techniques (e.g. DNA extraction, purification and subsequent PCR) have scarcely been applied. Here, DNA preparations of soil samples artificially contaminated with genomic DNA or parasite eggs were examined by PCR. A. caninum and T. canis-specific primers based on the ITS-2 sequence were used for amplification. After the sheer DNA preparation a high content of PCR-interfering substances was still detectable. Subsequently, two different inhibitors of PCR-interfering agents (GeneReleaser, Bioventures Inc. and Maximator, Connex GmbH) were compared in PCR. Both substances increased PCR sensitivity greatly. However, comparison of the increase in sensitivity achieved with the two compounds demonstrated the superiority of Maximator, which enhanced sensitivity to the point of permitting positive detection of a single A. caninum egg and three T. canis eggs in a soil sample. This degree of sensitivity could not be achieved with GeneReleaser for either parasite Furthermore, Maximator not only increased sensitivity; it also cost less, required less time and had a lower risk of contamination. Future applications of molecular methods in epidemiological examinations of soil samples are discussed/elaborated.
NASA Technical Reports Server (NTRS)
Goodman, P.
1973-01-01
A study has been conducted to determine the feasibility of increasing sensitivity for ozone detection. The detection technique employed is the chemiluminescent reaction of ozone with a rhodamine-B impregnated disk. Previously achieved sensitivities are required to be increased by a factor of about 20 to permit measurements at altitudes of 80 km. Sensitivity was increased by using a more sensitive photomultiplier tube, by increasing the gas velocity past the disk, by different disk preparation techniques, and by using reflective coatings in the disk chamber and on the uncoated side of the glass disk. Reflective coatings provided the largest sensitivity increase. The sum of all these changes was a sensitivity increased by an estimated factor of 70, more than sufficient to permit measurement of ambient ozone concentrations at altitudes of 80 km.
Wahlström, Helene; Comin, Arianna; Isaksson, Mats; Deplazes, Peter
2016-01-01
A semi-automated magnetic capture probe-based DNA extraction and real-time PCR method (MC-PCR), allowing for a more efficient large-scale surveillance of Echinococcus multilocularis occurrence, has been developed. The test sensitivity has previously been evaluated using the sedimentation and counting technique (SCT) as a gold standard. However, as the sensitivity of the SCT is not 1, test characteristics of the MC-PCR was also evaluated using latent class analysis, a methodology not requiring a gold standard. Test results, MC-PCR and SCT, from a previous evaluation of the MC-PCR using 177 foxes shot in the spring (n=108) and autumn 2012 (n=69) in high prevalence areas in Switzerland were used. Latent class analysis was used to estimate the test characteristics of the MC-PCR. Although it is not the primary aim of this study, estimates of the test characteristics of the SCT were also obtained. This study showed that the sensitivity of the MC-PCR was 0.88 [95% posterior credible interval (PCI) 0.80-0.93], which was not significantly different than the SCT, 0.83 (95% PCI 0.76-0.88), which is currently considered as the gold standard. The specificity of both tests was high, 0.98 (95% PCI 0.94-0.99) for the MC-PCR and 0.99 (95% PCI 0.99-1) for the SCT. In a previous study, using fox scats from a low prevalence area, the specificity of the MC-PCR was higher, 0.999% (95% PCI 0.997-1). One reason for the lower estimate of the specificity in this study could be that the MC-PCR detects DNA from infected but non-infectious rodents eaten by foxes. When using MC-PCR in low prevalence areas or areas free from the parasite, a positive result in the MC-PCR should be regarded as a true positive. The sensitivity of the MC-PCR (0.88) was comparable to the sensitivity of SCT (0.83).
Suzuki, Kenji
2009-09-21
Computer-aided diagnosis (CAD) has been an active area of study in medical image analysis. A filter for the enhancement of lesions plays an important role for improving the sensitivity and specificity in CAD schemes. The filter enhances objects similar to a model employed in the filter; e.g. a blob-enhancement filter based on the Hessian matrix enhances sphere-like objects. Actual lesions, however, often differ from a simple model; e.g. a lung nodule is generally modeled as a solid sphere, but there are nodules of various shapes and with internal inhomogeneities such as a nodule with spiculations and ground-glass opacity. Thus, conventional filters often fail to enhance actual lesions. Our purpose in this study was to develop a supervised filter for the enhancement of actual lesions (as opposed to a lesion model) by use of a massive-training artificial neural network (MTANN) in a CAD scheme for detection of lung nodules in CT. The MTANN filter was trained with actual nodules in CT images to enhance actual patterns of nodules. By use of the MTANN filter, the sensitivity and specificity of our CAD scheme were improved substantially. With a database of 69 lung cancers, nodule candidate detection by the MTANN filter achieved a 97% sensitivity with 6.7 false positives (FPs) per section, whereas nodule candidate detection by a difference-image technique achieved a 96% sensitivity with 19.3 FPs per section. Classification-MTANNs were applied for further reduction of the FPs. The classification-MTANNs removed 60% of the FPs with a loss of one true positive; thus, it achieved a 96% sensitivity with 2.7 FPs per section. Overall, with our CAD scheme based on the MTANN filter and classification-MTANNs, an 84% sensitivity with 0.5 FPs per section was achieved.
PADF RF localization experiments with multi-agent caged-MAV platforms
NASA Astrophysics Data System (ADS)
Barber, Christopher; Gates, Miguel; Selmic, Rastko; Al-Issa, Huthaifa; Ordonez, Raul; Mitra, Atindra
2011-06-01
This paper provides a summary of preliminary RF direction finding results generated within an AFOSR funded testbed facility recently developed at Louisiana Tech University. This facility, denoted as the Louisiana Tech University Micro- Aerial Vehicle/Wireless Sensor Network (MAVSeN) Laboratory, has recently acquired a number of state-of-the-art MAV platforms that enable us to analyze, design, and test some of our recent results in the area of multiplatform position-adaptive direction finding (PADF) [1] [2] for localization of RF emitters in challenging embedded multipath environments. Discussions within the segmented sections of this paper include a description of the MAVSeN Laboratory and the preliminary results from the implementation of mobile platforms with the PADF algorithm. This novel approach to multi-platform RF direction finding is based on the investigation of iterative path-loss based (i.e. path loss exponent) metrics estimates that are measured across multiple platforms in order to develop a control law that robotically/intelligently positionally adapt (i.e. self-adjust) the location of each distributed/cooperative platform. The body of this paper provides a summary of our recent results on PADF and includes a discussion on state-of-the-art Sensor Mote Technologies as applied towards the development of sensor-integrated caged-MAV platform for PADF applications. Also, a discussion of recent experimental results that incorporate sample approaches to real-time singleplatform data pruning is included as part of a discussion on potential approaches to refining a basic PADF technique in order to integrate and perform distributed self-sensitivity and self-consistency analysis as part of a PADF technique with distributed robotic/intelligent features. These techniques are extracted in analytical form from a parallel study denoted as "PADF RF Localization Criteria for Multi-Model Scattering Environments". The focus here is on developing and reporting specific approaches to self-sensitivity and self-consistency within this experimental PADF framework via the exploitation of specific single-agent caged-MAV trajectories that are unique to this experiment set.
Wölfel, Roman; Pfeffer, Martin; Essbauer, Sandra; Nerkelun, Sylke; Dobler, Gerhard
2006-11-01
Human adenoviruses (HAdV) may cause pharyngoconjunctival fever, follicular conjunctivitis or epidemic keratoconjunctivitis (EKC). Especially, outbreaks of the latter may lead to severe economic losses when preventive measures are implemented too late. Thus, a safe sampling method, proper specimen transport conditions and a fast and sensitive diagnostic technique is mandatory. Two commercially available virus transport systems (VTS) were compared with two NaCl-moisturised sampling devices, one of which comprises Dacron-tipped plastic-shafted swabs and the other a cotton-tipped wood-shafted swab, available in most ophthalmologists' offices. Downstream methods for specific detection of HAdV included direct immunofluorescence assay (IFA) of conjunctival swabs, virus isolation by cell culture and quantitative real-time polymerase chain reaction (qPCR). Furthermore, the influence of application of local anaesthetics prior to swabbing on subsequent detection of HAdV was investigated. Application of local anaesthetics had a positive influence on the amount of swabbed cells, thus increasing the chance of obtaining positive results by IFA. Neither isolation of HAdV by cell culture nor by qPCR was negatively influenced by this pretreatment. Surprisingly, both commercially available VTS performed significantly worse than the NaCl-moisturised swabs. This was shown with regard to virus recovery rates in cell culture as well as viral genome copy numbers in the qPCR. Based on our results, the following recommendations are provided to improve sampling, transport and diagnostic techniques regarding conjunctival swabs for diagnosis of human adenovirus infection: (1) application of local anaesthetics, (2) NaCl-moisturised VTS for shipment of specimens, and (3) detection of HAdV by qPCR. The latter method proved to be superior to virus isolation by cell culture, including subsequent identification by IFA, because it is faster, more sensitive and allows simultaneous handling of a number of samples. Hence, countermeasures to prevent further virus spread in an outbreak situation can be implemented earlier, thus reducing the number of subsequent adenoviral infections.
Khedmat, S; Rouhi, N; Drage, N; Shokouhinejad, N; Nekoofar, M H
2012-11-01
To compare the accuracy of digital radiography (DR), multidetector computed tomography (MDCT) and cone beam computed tomography (CBCT) in detecting vertical root fractures (VRF) in the absence and presence of gutta-percha root filling. The root canals of 100 extracted human single-rooted teeth were prepared and randomly divided into four groups: two experimental groups with artificially fractured root and two intact groups as controls. In one experimental and one control group, a size 40, 0.04 taper gutta-percha cone was inserted in the root canals. Then DR, MDCT and CBCT were performed and the images evaluated. Statistical analyses of sensitivity, specificity and accuracy of each imaging technique in the presence and absence of gutta-percha were calculated and compared. In the absence of gutta-percha, the specificity of DR, MDCT and CBCT was similar. CBCT was the most accurate and sensitive imaging technique (P < 0 .05). In the presence of gutta-percha, the accuracy of MDCT was higher than the other imaging techniques (P < 0.05). The sensitivity of CBCT and MDCT was significantly higher than that of DR (P < 0.05), whereas CBCT was the least specific technique. Under the conditions of this ex vivo study, CBCT was the most sensitive imaging technique in detecting vertical root fracture. The presence of gutta-percha reduced the accuracy, sensitivity and specificity of CBCT but not MDCT. The sensitivity of DR was reduced in the presence of gutta-percha. The use of MDCT as an alternative technique may be recommended when VRF are suspected in root filled teeth. However, as the radiation dose of MDCT is higher than CBCT, the technique could be considered at variance with the principles of ALARA. © 2012 International Endodontic Journal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lobb, Eric, E-mail: eclobb2@gmail.com
2014-04-01
The dosimetric effect of errors in patient position is studied on-phantom as a function of simulated bolus thickness to assess the need for bolus utilization in scalp radiotherapy with tomotherapy. A treatment plan is generated on a cylindrical phantom, mimicking a radiotherapy technique for the scalp utilizing primarily tangential beamlets. A planning target volume with embedded scalplike clinical target volumes (CTVs) is planned to a uniform dose of 200 cGy. Translational errors in phantom position are introduced in 1-mm increments and dose is recomputed from the original sinogram. For each error the maximum dose, minimum dose, clinical target dose homogeneitymore » index (HI), and dose-volume histogram (DVH) are presented for simulated bolus thicknesses from 0 to 10 mm. Baseline HI values for all bolus thicknesses were in the 5.5 to 7.0 range, increasing to a maximum of 18.0 to 30.5 for the largest positioning errors when 0 to 2 mm of bolus is used. Utilizing 5 mm of bolus resulted in a maximum HI value of 9.5 for the largest positioning errors. Using 0 to 2 mm of bolus resulted in minimum and maximum dose values of 85% to 94% and 118% to 125% of the prescription dose, respectively. When using 5 mm of bolus these values were 98.5% and 109.5%. DVHs showed minimal changes in CTV dose coverage when using 5 mm of bolus, even for the largest positioning errors. CTV dose homogeneity becomes increasingly sensitive to errors in patient position as bolus thickness decreases when treating the scalp with primarily tangential beamlets. Performing a radial expansion of the scalp CTV into 5 mm of bolus material minimizes dosimetric sensitivity to errors in patient position as large as 5 mm and is therefore recommended.« less
Rôças, I N; Lima, K C; Siqueira, J F
2013-07-01
To compare the antibacterial efficacy of two instrumentation techniques, one using hand nickel-titanium (NiTi) instruments and the other using rotary NiTi instruments, in root canals of teeth with apical periodontitis. Root canals from single-rooted teeth were instrumented using either hand NiTi instruments in the alternated rotation motion technique or rotary BioRaCe instruments. The irrigant used in both groups was 2.5% NaOCl. DNA extracts from samples taken before and after instrumentation were subjected to quantitative analysis by real-time polymerase chain reaction (qPCR). Qualitative analysis was also performed using presence/absence data from culture and qPCR assays. Bacteria were detected in all S1 samples by both methods. In culture analysis, 45% and 35% of the canals were still positive for bacterial presence after hand and rotary NiTi instrumentation, respectively (P > 0.05). Rotary NiTi instrumentation resulted in significantly fewer qPCR-positive cases (60%) than hand NiTi instrumentation (95%) (P = 0.01). Intergroup comparison of quantitative data showed no significant difference between the two techniques. There was no significant difference in bacterial reduction in infected canals after instrumentation using hand or rotary NiTi instruments. In terms of incidence of positive results for bacteria, culture also showed no significant differences between the groups, but the rotary NiTi instrumentation resulted in more negative results in the more sensitive qPCR analysis. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.
An integrated approach to piezoactuator positioning in high-speed atomic force microscope imaging
NASA Astrophysics Data System (ADS)
Yan, Yan; Wu, Ying; Zou, Qingze; Su, Chanmin
2008-07-01
In this paper, an integrated approach to achieve high-speed atomic force microscope (AFM) imaging of large-size samples is proposed, which combines the enhanced inversion-based iterative control technique to drive the piezotube actuator control for lateral x-y axis positioning with the use of a dual-stage piezoactuator for vertical z-axis positioning. High-speed, large-size AFM imaging is challenging because in high-speed lateral scanning of the AFM imaging at large size, large positioning error of the AFM probe relative to the sample can be generated due to the adverse effects—the nonlinear hysteresis and the vibrational dynamics of the piezotube actuator. In addition, vertical precision positioning of the AFM probe is even more challenging (than the lateral scanning) because the desired trajectory (i.e., the sample topography profile) is unknown in general, and the probe positioning is also effected by and sensitive to the probe-sample interaction. The main contribution of this article is the development of an integrated approach that combines advanced control algorithm with an advanced hardware platform. The proposed approach is demonstrated in experiments by imaging a large-size (50μm ) calibration sample at high-speed (50Hz scan rate).
Tseng, Shao-Chin; Yu, Chen-Chieh; Wan, Dehui; Chen, Hsuen-Li; Wang, Lon Alex; Wu, Ming-Chung; Su, Wei-Fang; Han, Hsieh-Cheng; Chen, Li-Chyong
2012-06-05
Convenient, rapid, and accurate detection of chemical and biomolecules would be a great benefit to medical, pharmaceutical, and environmental sciences. Many chemical and biosensors based on metal nanoparticles (NPs) have been developed. However, as a result of the inconvenience and complexity of most of the current preparation techniques, surface plasmon-based test papers are not as common as, for example, litmus paper, which finds daily use. In this paper, we propose a convenient and practical technique, based on the photothermal effect, to fabricate the plasmonic test paper. This technique is superior to other reported methods for its rapid fabrication time (a few seconds), large-area throughput, selectivity in the positioning of the NPs, and the capability of preparing NP arrays in high density on various paper substrates. In addition to their low cost, portability, flexibility, and biodegradability, plasmonic test paper can be burned after detecting contagious biomolecules, making them safe and eco-friendly.
Feasibility of reading LiF thermoluminescent dosimeters by electron spin resonance
NASA Astrophysics Data System (ADS)
Breen, S. L.; Battista, J. J.
1999-08-01
Lithium fluoride is a commonly used solid state dosimeter. During irradiation, electrons and holes become trapped in crystal imperfections; thermoluminescence dosimetry measures their thermally induced recombination. Electron paramagnetic resonance (EPR) spectroscopy can be used to measure the resonant absorption of microwaves by the unpaired electrons trapped in LiF. In an effort to extend the use of LiF dosimeters to smaller sizes and to the harsh environments encountered in internal dosimetry, EPR was evaluated as an alternative technique to read the radiation dose delivered to TLD-100 dosimeters. TLD-100 rods were irradiated with a 60Co source to doses of 10 Gy to 100 Gy. A radiation-induced signal (with a g-value of 2.002) could be detected only at liquid nitrogen temperatures at doses above 20 Gy. The EPR spectrum of irradiated LiF contains three components, one of which correlates positively with dose. However, the low sensitivity of the technique, and difficulty in interpreting the EPR spectrum from polycrystalline dosimeters, preclude its use as a dosimetry technique.
Feasibility of reading LiF thermoluminescent dosimeters by electron spin resonance.
Breen, S L; Battista, J J
1999-08-01
Lithium fluoride is a commonly used solid state dosimeter. During irradiation, electrons and holes become trapped in crystal imperfections; thermoluminescence dosimetry measures their thermally induced recombination. Electron paramagnetic resonance (EPR) spectroscopy can be used to measure the resonant absorption of microwaves by the unpaired electrons trapped in LiF. In an effort to extend the use of LiF dosimeters to smaller sizes and to the harsh environments encountered in internal dosimetry, EPR was evaluated as an alternative technique to read the radiation dose delivered to TLD-100 dosimeters. TLD-100 rods were irradiated with a 60Co source to doses of 10 Gy to 100 Gy. A radiation-induced signal (with a g-value of 2.002) could be detected only at liquid nitrogen temperatures at doses above 20 Gy. The EPR spectrum of irradiated LiF contains three components, one of which correlates positively with dose. However, the low sensitivity of the technique, and difficulty in interpreting the EPR spectrum from polycrystalline dosimeters, preclude its use as a dosimetry technique.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mihailescu, Lucian
This disclosure provides systems, methods, and apparatus related to ion beam therapy. In one aspect, a system includes a position sensitive detector and a collimator. The position sensitive detector configured to detect gamma rays generated by an ion beam interacting with a target. The collimator is positioned between the target and the position sensitive detector. The collimator includes a plurality of knife-edge slits, with a first knife-edge slit intersecting with a second knife-edge slit.
Miri, Shimasadat; Mehralizadeh, Sandra; Sadri, Donya; Motamedi, Mahmood Reza Kalantar
2015-01-01
Purpose This study evaluated the diagnostic accuracy of the reverse contrast mode in intraoral digital radiography for the detection of proximal dentinal caries, in comparison with the original digital radiographs. Materials and Methods Eighty extracted premolars with no clinically apparent caries were selected, and digital radiographs of them were taken separately in standard conditions. Four observers examined the original radiographs and the same radiographs in the reverse contrast mode with the goal of identifying proximal dentinal caries. Microscopic sections 5 µm in thickness were prepared from the teeth in the mesiodistal direction. Four slides prepared from each sample used as the diagnostic gold standard. The data were analyzed using SPSS (α=0.05). Results Our results showed that the original radiographs in order to identify proximal dentinal caries had the following values for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, respectively: 72.5%, 90%, 87.2%, 76.5%, and 80.9%. For the reverse contrast mode, however, the corresponding values were 63.1%, 89.4%, 87.1%, 73.5%, and 78.8%, respectively. The sensitivity of original digital radiograph for detecting proximal dentinal caries was significantly higher than that of reverse contrast mode (p<0.05). However, no statistically significant differences were found regarding specificity, positive predictive value, negative predictive value, or accuracy (p>0.05). Conclusion The sensitivity of the original digital radiograph for detecting proximal dentinal caries was significantly higher than that of the reversed contrast images. However, no statistically significant differences were found between these techniques regarding specificity, positive predictive value, negative predictive value, or accuracy. PMID:26389055
Freeze-drying process monitoring using a cold plasma ionization device.
Mayeresse, Y; Veillon, R; Sibille, P H; Nomine, C
2007-01-01
A cold plasma ionization device has been designed to monitor freeze-drying processes in situ by monitoring lyophilization chamber moisture content. This plasma device, which consists of a probe that can be mounted directly on the lyophilization chamber, depends upon the ionization of nitrogen and water molecules using a radiofrequency generator and spectrometric signal collection. The study performed on this probe shows that it is steam sterilizable, simple to integrate, reproducible, and sensitive. The limitations include suitable positioning in the lyophilization chamber, calibration, and signal integration. Sensitivity was evaluated in relation to the quantity of vials and the probe positioning, and correlation with existing methods, such as microbalance, was established. These tests verified signal reproducibility through three freeze-drying cycles. Scaling-up studies demonstrated a similar product signature for the same product using pilot-scale and larger-scale equipment. On an industrial scale, the method efficiently monitored the freeze-drying cycle, but in a larger industrial freeze-dryer the signal was slightly modified. This was mainly due to the positioning of the plasma device, in relation to the vapor flow pathway, which is not necessarily homogeneous within the freeze-drying chamber. The plasma tool is a relevant method for monitoring freeze-drying processes and may in the future allow the verification of current thermodynamic freeze-drying models. This plasma technique may ultimately represent a process analytical technology (PAT) approach for the freeze-drying process.
[Assessment of a rapid diagnostic test for malaria in rural health care facilities in Senegal].
Munier, A; Diallo, A; Sokhna, C; Chippaux, J P
2009-10-01
The aim of the study was to determine the accuracy of a rapid diagnostic test in confirming presumptive malaria diagnosis in a rural zone of Senegal. Thick blood smear was used as the reference technique for comparison. METHOHDOLOGY: Testing was conducted on children between the ages of 1 and 14 years at three health care facilities located in the Niakhar are from August 2006 to June 2007. If malaria was suspected by the nurse based on clinical findings, two thick smears and one rapid diagnostic test (Core Malaria Pf) were performed. Blood slides were stained in Niakhar and read in Dakar. A total of 474 patients were examined. Three-fourths (75%) of these patients were seen during the rainy season. Malaria was suspected in 335 patients (71%). Rapid tests and thick smears were obtained in 330 of these patients with positive results in 194 (59%) and 180 (55%) respectively. The sensitivity, specificity, positive predictive value and negative predictive value of the rapid test were 96%, 87%, 90% and 95% respectively. Our data show that the rapid diagnostic test used in this study exhibits good sensitivity and positive predictive value. Despite its cost this test could be helpful in confirming malaria diagnosis in outlying health care facilities without the necessary resources to perform blood smears. Confirmation is necessary to avoid unwarranted prescription of malaria treatment due to inaccurate clinical diagnosis
Single-Photon Computed Tomography With Large Position-Sensitive Phototubes*
NASA Astrophysics Data System (ADS)
Feldmann, John; Ranck, Amoreena; Saunders, Robert S.; Welsh, Robert E.; Bradley, Eric L.; Saha, Margaret S.; Kross, Brian; Majewski, Stan; Popov, Vladimir; Weisenberger, Andrew G.; Wojcik, Randolph
2000-10-01
Position-sensitive photomultiplier tubes (PSPMTs) coupled to pixelated CsI(Tl) scintillators have been used with parallel-hole collimators to view the metabolism in small animals of radiopharmaceuticals tagged with ^125I. We report here our preliminary results analyzed using a tomography program^1 written in IDL programming language. The PSPMTs are mounted on a rotating gantry so as to view the subject animal from any azimuth. Preliminary results to test the tomography algorithm have been obtained by placing a variety of plastic mouse-brain phantoms (loaded with Na^125I) in front of one of the detectors and rotating the phantom in steps through 360 degrees. Results of this simulation taken with a variety of collimator hole sizes will be compared and discussed. Extentions of this technique to the use of very small PSPMTs (Hamamatsu M-64) which are capable of a very close approach to those parts of the animal of greatest interest will be described. *Supported in part by The Department of Energy, The National Science Foundation, The American Diabetes Association, The Howard Hughes Foundation and The Jeffress Trust. 1. Tomography algorithm kindly provided by Dr. S. Meikle of The Royal Prince Albert Hospital, Sydney, Australia
Groman, Stephanie M.; James, Alex S.; Seu, Emanuele; Tran, Steven; Clark, Taylor A.; Harpster, Sandra N.; Crawford, Maverick; Burtner, Joanna Lee; Feiler, Karen; Roth, Robert H.; Elsworth, John D.; London, Edythe D.
2014-01-01
For >30 years, positron emission tomography (PET) has proven to be a powerful approach for measuring aspects of dopaminergic transmission in the living human brain; this technique has revealed important relationships between dopamine D2-like receptors and dimensions of normal behavior, such as human impulsivity, and psychopathology, particularly behavioral addictions. Nevertheless, PET is an indirect estimate that lacks cellular and functional resolution and, in some cases, is not entirely pharmacologically specific. To identify the relationships between PET estimates of D2-like receptor availability and direct in vitro measures of receptor number, affinity, and function, we conducted neuroimaging and behavioral and molecular pharmacological assessments in a group of adult male vervet monkeys. Data gathered from these studies indicate that variation in D2-like receptor PET measurements is related to reversal-learning performance and sensitivity to positive feedback and is associated with in vitro estimates of the density of functional dopamine D2-like receptors. Furthermore, we report that a simple behavioral measure, eyeblink rate, reveals novel and crucial links between neuroimaging assessments and in vitro measures of dopamine D2 receptors. PMID:25339755
Clarke, Sharon E; Mistry, Dipan; AlThubaiti, Talal; Khan, M Naeem; Morris, David; Bance, Manohar
2017-05-01
The purpose of this study was to evaluate the sensitivity, specificity, and positive and negative predictive values of the diffusion-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique in the detection of cholesteatoma at our institution with surgical confirmation in all cases. A retrospective review of 21 consecutive patients who underwent diffusion-weighted PROPELLER magnetic resonance imaging (MRI) on a 1.5T MRI scanner prior to primary or revision/second-look surgery for suspected cholesteatoma from 2009-2012 was performed. Diffusion-weighted PROPELLER had a sensitivity of 75%, specificity of 60%, positive predictive value of 86%, and negative predictive value of 43%. In the 15 patients for whom the presence or absence of cholesteatoma was correctly predicted, there were 2 cases where the reported locations of diffusion restriction did not correspond to the location of the cholesteatoma observed at surgery. On the basis of our retrospective study, we conclude that diffusion-weighted PROPELLER MRI is not sufficiently accurate to replace second look surgery at our institution. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.
Parameter Optimization for Selected Correlation Analysis of Intracranial Pathophysiology.
Faltermeier, Rupert; Proescholdt, Martin A; Bele, Sylvia; Brawanski, Alexander
2015-01-01
Recently we proposed a mathematical tool set, called selected correlation analysis, that reliably detects positive and negative correlations between arterial blood pressure (ABP) and intracranial pressure (ICP). Such correlations are associated with severe impairment of the cerebral autoregulation and intracranial compliance, as predicted by a mathematical model. The time resolved selected correlation analysis is based on a windowing technique combined with Fourier-based coherence calculations and therefore depends on several parameters. For real time application of this method at an ICU it is inevitable to adjust this mathematical tool for high sensitivity and distinct reliability. In this study, we will introduce a method to optimize the parameters of the selected correlation analysis by correlating an index, called selected correlation positive (SCP), with the outcome of the patients represented by the Glasgow Outcome Scale (GOS). For that purpose, the data of twenty-five patients were used to calculate the SCP value for each patient and multitude of feasible parameter sets of the selected correlation analysis. It could be shown that an optimized set of parameters is able to improve the sensitivity of the method by a factor greater than four in comparison to our first analyses.
Parameter Optimization for Selected Correlation Analysis of Intracranial Pathophysiology
Faltermeier, Rupert; Proescholdt, Martin A.; Bele, Sylvia; Brawanski, Alexander
2015-01-01
Recently we proposed a mathematical tool set, called selected correlation analysis, that reliably detects positive and negative correlations between arterial blood pressure (ABP) and intracranial pressure (ICP). Such correlations are associated with severe impairment of the cerebral autoregulation and intracranial compliance, as predicted by a mathematical model. The time resolved selected correlation analysis is based on a windowing technique combined with Fourier-based coherence calculations and therefore depends on several parameters. For real time application of this method at an ICU it is inevitable to adjust this mathematical tool for high sensitivity and distinct reliability. In this study, we will introduce a method to optimize the parameters of the selected correlation analysis by correlating an index, called selected correlation positive (SCP), with the outcome of the patients represented by the Glasgow Outcome Scale (GOS). For that purpose, the data of twenty-five patients were used to calculate the SCP value for each patient and multitude of feasible parameter sets of the selected correlation analysis. It could be shown that an optimized set of parameters is able to improve the sensitivity of the method by a factor greater than four in comparison to our first analyses. PMID:26693250
Neurons as sensors: individual and cascaded chemical sensing.
Prasad, Shalini; Zhang, Xuan; Yang, Mo; Ozkan, Cengiz S; Ozkan, Mihrimah
2004-07-15
A single neuron sensor has been developed based on the interaction of gradient electric fields and the cell membrane. Single neurons are rapidly positioned over individual microelectrodes using positive dielectrophoretic traps. This enables the continuous extracellular electrophysiological measurements from individual neurons. The sensor developed using this technique provides the first experimental method for determining single cell sensitivity; the speed of response and the associated physiological changes to a broad spectrum of chemical agents. Binding of specific chemical agents to a specific combination of receptors induces changes to the extracellular membrane potential of a single neuron, which can be translated into unique "signature patterns" (SP), which function as identification tags. Signature patterns are derived using Fast Fourier Transformation (FFT) analysis and Wavelet Transformation (WT) analysis of the modified extracellular action potential. The validity and the sensitivity of the system are demonstrated for a variety of chemical agents ranging from behavior altering chemicals (ethanol), environmentally hazardous agents (hydrogen peroxide, EDTA) to physiologically harmful agents (pyrethroids) at pico- and femto-molar concentrations. The ability of a single neuron to selectively identify specific chemical agents when injected in a serial manner is demonstrated in "cascaded sensing".
Fry, Brendan C.; Layton, Anita T.
2014-01-01
We have developed a highly detailed mathematical model of oxygen transport in a cross section of the upper inner medulla of the rat kidney. The model is used to study the impact of the structured organization of nephrons and vessels revealed in anatomic studies, in which descending vasa recta are found to lie distant from clusters of collecting ducts. Specifically, we formulated a two-dimensional oxygen transport model, in which the positions and physical dimensions of renal tubules and vessels are based on an image obtained by immunochemical techniques (Pannabecker and Dantzler, Am J Physiol Renal Physiol, 2006). The model represents oxygen diffusion through interstitium and other renal structures, oxygen consumption by the Na+/K+-ATPase activities of the collecting ducts, and basal metabolic consumption. Model simulations yield marked variations in interstitial PO2, which can be attributed, in large part, to the heterogeneities in the position and physical dimensions of the collecting ducts. Further, results of a sensitivity study suggest that medullary oxygenation is highly sensitive to medullary blood flow, and that, at high active consumption rates, localized patches of tissue may be vulnerable to hypoxic injury. PMID:25260928
da Costa, Priscilla Almeida; Segatto, Marcela; Durso, Danielle Fernandes; de Carvalho Moreira, Wagson José; Junqueira, Lucas Lodi; de Castilho, Fábio Morato; de Andrade, Silvio Amadeu; Gelape, Cláudio Léo; Chiari, Egler; Teixeira-Carvalho, Andréa; Junho Pena, Sergio Danilo; Machado, Carlos Renato; Franco, Gloria Regina; Filho, Geraldo Brasileiro; Vieira Moreira, Maria da Consolação; Mara Macedo, Andréa
2017-07-01
Heart transplantation is a valuable therapeutic option for Chagas disease patients with severe cardiomyopathy. During patient follow-up, the differential diagnosis between cardiac transplant rejection and Chagas disease infection reactivation remains a challenging task, which hinders rapid implementation of the appropriate treatment. Herein we investigate whether polymerase chain reaction (PCR) strategies could facilitate early detection of Trypanosoma cruzi (T cruzi) in transplanted endomyocardial biopsies (EMBs). In this study we analyzed 500 EMB specimens obtained from 58 chagasic cardiac transplant patients, using PCR approaches targeted to nuclear (rDNA 24Sα) and kinetoplastid (kDNA) markers, and compared the efficiency of these approaches with that of other tests routinely used. T cruzi DNA was detected in 112 EMB specimens derived from 39 patients (67.2%). The first positive result occurred at a median 1.0 month post-transplant. Conventional histopathologic, blood smear and hemoculture analyses showed lower sensitivity and higher median time to the first positive result. Patient follow-up revealed that 31 of 39 PCR-positive cases presented clinical reactivation of Chagas disease at different time-points after transplantation. PCR techniques showed considerable sensitivity (0.82) and specificity (0.60), with area under the receiver operating characteristic (ROC) curves of 0.708 (p = 0.001). Moreover, PCR techniques anticipated the clinical signs of Chagas disease reactivation by up to 36 months, with a median time of 6 months and an average of 9.1 months. We found a good association between the PCR diagnosis and the clinical signs of the disease, indicating that the PCR approaches used herein are suitable for early diagnosis of Chagas disease reactivation, with high potential to assist physicians in treatment decisions. For this purpose, an algorithm is proposed for surveillance based on the molecular tests. Copyright © 2017 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Yock, Adam D; Pawlicki, Todd; Kim, Gwe-Ya
2016-07-01
In surface image guided radiosurgery, action limits are created to determine at what point intrafractional motion exhibited by the patient is large enough to warrant intervention. Action limit values remain constant across patients despite the fact that patient motion affects the target coverage of brain metastases differently depending on the planning technique and other treatment plan-specific factors. The purpose of this work was twofold. The first purpose was to characterize the sensitivity of single-met per iso and multimet per iso treatment plans to uncorrected patient motion. The second purpose was to describe a method to prospectively determine treatment plan-specific action limits considering this sensitivity. In their surface image guided radiosurgery technique, patient positioning is achieved with a thermoplastic mask that does not cover the patient's face. The patient's exposed face is imaged by a stereoscopic photogrammetry system. It is then compared to a reference surface and monitored throughout treatment. Seventy-two brain metastases (representing 29 patients) were used for this study. Twenty-five mets were treated individually ("single-met per iso plans"), and 47 were treated in a plan simultaneously with at least one other met ("multimet per iso plans"). For each met, the proportion of the gross tumor volume that remained within the 100% prescription isodose line was estimated under the influence of combinations of translations and rotations (0.0-3.0 mm and 0.0°-3.0°, respectively). The target volume and the prescription dose-volume were considered concentric spheres that each encompassed a volume determined from the treatment plan. Plan-specific contour plots and DVHs were created to illustrate the sensitivity of a specific lesion to uncorrected patient motion. Both single-met per iso and multimet per iso plans exhibited compromised target coverage under translations and rotations, though multimet per iso plans were considerably more sensitive to these transformations (2.3% and 39.8%, respectively). Plan-specific contour plots and DVHs were used to illustrate how size, distance from isocenter, and planning technique affect a particular met's sensitivity to motion. Stereotactic radiosurgery treatment plans that treat multiple brain metastases using a common isocenter are particularly susceptible to compromised target coverage as a result of uncorrected patient motion. The use of such a planning technique along with other treatment plan-specific factors should influence patient motion management. A graphical representation of the effect of translations and rotations on any particular plan can be generated to inform clinicians of the appropriate action limit when monitoring intrafractional motion.
[THE ROLE OF SYSTEM QUORUM SENSING UNDER CHRONIC UROGENITAL CHLAMYDIA INFECTION].
2015-10-01
It is established that system quorum sensing (QS) assure social behavior of bacteria in regulation of genes of virulence and generalization of inflectional inflammatory process under chronic urogenital chlamydia infection. The techniques of gas chromatography and mass-spectrometry were applied to detect molecular markers of generalization of infectious process under urogenital chlamydiasis--activators of QS microbes (lactones, quinolones, furan ethers). The developed diagnostic gas chromatography and mass-spectrometry criteria of indexation of molecular markers under chronic urogenital chlamydia infection have high level of diagnostic sensitivity, specificity and prognostic value of positive and negative result. The application of techniques of gas chromatography and mass-spectrometry permits enhancing effectiveness of diagnostic of chronic inflectional inflammatory diseases of urogenital system of chlamydia etiology with identification of prognostic criteria of generalization of infectious process and subsequent prescription of timely and appropriate therapy
Large-volume protein crystal growth for neutron macromolecular crystallography
Ng, Joseph D.; Baird, James K.; Coates, Leighton; ...
2015-03-30
Neutron macromolecular crystallography (NMC) is the prevailing method for the accurate determination of the positions of H atoms in macromolecules. As neutron sources are becoming more available to general users, finding means to optimize the growth of protein crystals to sizes suitable for NMC is extremely important. Historically, much has been learned about growing crystals for X-ray diffraction. However, owing to new-generation synchrotron X-ray facilities and sensitive detectors, protein crystal sizes as small as in the nano-range have become adequate for structure determination, lessening the necessity to grow large crystals. Here, some of the approaches, techniques and considerations for themore » growth of crystals to significant dimensions that are now relevant to NMC are revisited. We report that these include experimental strategies utilizing solubility diagrams, ripening effects, classical crystallization techniques, microgravity and theoretical considerations.« less
Large-volume protein crystal growth for neutron macromolecular crystallography
Ng, Joseph D.; Baird, James K.; Coates, Leighton; Garcia-Ruiz, Juan M.; Hodge, Teresa A.; Huang, Sijay
2015-01-01
Neutron macromolecular crystallography (NMC) is the prevailing method for the accurate determination of the positions of H atoms in macromolecules. As neutron sources are becoming more available to general users, finding means to optimize the growth of protein crystals to sizes suitable for NMC is extremely important. Historically, much has been learned about growing crystals for X-ray diffraction. However, owing to new-generation synchrotron X-ray facilities and sensitive detectors, protein crystal sizes as small as in the nano-range have become adequate for structure determination, lessening the necessity to grow large crystals. Here, some of the approaches, techniques and considerations for the growth of crystals to significant dimensions that are now relevant to NMC are revisited. These include experimental strategies utilizing solubility diagrams, ripening effects, classical crystallization techniques, microgravity and theoretical considerations. PMID:25849493
Large-volume protein crystal growth for neutron macromolecular crystallography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ng, Joseph D.; Baird, James K.; Coates, Leighton
Neutron macromolecular crystallography (NMC) is the prevailing method for the accurate determination of the positions of H atoms in macromolecules. As neutron sources are becoming more available to general users, finding means to optimize the growth of protein crystals to sizes suitable for NMC is extremely important. Historically, much has been learned about growing crystals for X-ray diffraction. However, owing to new-generation synchrotron X-ray facilities and sensitive detectors, protein crystal sizes as small as in the nano-range have become adequate for structure determination, lessening the necessity to grow large crystals. Here, some of the approaches, techniques and considerations for themore » growth of crystals to significant dimensions that are now relevant to NMC are revisited. We report that these include experimental strategies utilizing solubility diagrams, ripening effects, classical crystallization techniques, microgravity and theoretical considerations.« less
Automated Track Recognition and Event Reconstruction in Nuclear Emulsion
NASA Technical Reports Server (NTRS)
Deines-Jones, P.; Cherry, M. L.; Dabrowska, A.; Holynski, R.; Jones, W. V.; Kolganova, E. D.; Kudzia, D.; Nilsen, B. S.; Olszewski, A.; Pozharova, E. A.;
1998-01-01
The major advantages of nuclear emulsion for detecting charged particles are its submicron position resolution and sensitivity to minimum ionizing particles. These must be balanced, however, against the difficult manual microscope measurement by skilled observers required for the analysis. We have developed an automated system to acquire and analyze the microscope images from emulsion chambers. Each emulsion plate is analyzed independently, allowing coincidence techniques to be used in order to reject back- ground and estimate error rates. The system has been used to analyze a sample of high-multiplicity Pb-Pb interactions (charged particle multiplicities approx. 1100) produced by the 158 GeV/c per nucleon Pb-208 beam at CERN. Automatically reconstructed track lists agree with our best manual measurements to 3%. We describe the image analysis and track reconstruction techniques, and discuss the measurement and reconstruction uncertainties.
The MAGIC Touch: Combining MAGIC-Pointing with a Touch-Sensitive Mouse
NASA Astrophysics Data System (ADS)
Drewes, Heiko; Schmidt, Albrecht
In this paper, we show how to use the combination of eye-gaze and a touch-sensitive mouse to ease pointing tasks in graphical user interfaces. A touch of the mouse positions the mouse pointer at the current gaze position of the user. Thus, the pointer is always at the position where the user expects it on the screen. This approach changes the user experience in tasks that include frequent switching between keyboard and mouse input (e.g. working with spreadsheets). In a user study, we compared the touch-sensitive mouse with a traditional mouse and observed speed improvements for pointing tasks on complex backgrounds. For pointing task on plain backgrounds, performances with both devices were similar, but users perceived the gaze-sensitive interaction of the touch-sensitive mouse as being faster and more convenient. Our results show that using a touch-sensitive mouse that positions the pointer on the user’s gaze position reduces the need for mouse movements in pointing tasks enormously.
NASA Technical Reports Server (NTRS)
Greene, William H.
1989-01-01
A study has been performed focusing on the calculation of sensitivities of displacements, velocities, accelerations, and stresses in linear, structural, transient response problems. One significant goal was to develop and evaluate sensitivity calculation techniques suitable for large-order finite element analyses. Accordingly, approximation vectors such as vibration mode shapes are used to reduce the dimensionality of the finite element model. Much of the research focused on the accuracy of both response quantities and sensitivities as a function of number of vectors used. Two types of sensitivity calculation techniques were developed and evaluated. The first type of technique is an overall finite difference method where the analysis is repeated for perturbed designs. The second type of technique is termed semianalytical because it involves direct, analytical differentiation of the equations of motion with finite difference approximation of the coefficient matrices. To be computationally practical in large-order problems, the overall finite difference methods must use the approximation vectors from the original design in the analyses of the perturbed models.
Development of a sensitivity analysis technique for multiloop flight control systems
NASA Technical Reports Server (NTRS)
Vaillard, A. H.; Paduano, J.; Downing, D. R.
1985-01-01
This report presents the development and application of a sensitivity analysis technique for multiloop flight control systems. This analysis yields very useful information on the sensitivity of the relative-stability criteria of the control system, with variations or uncertainties in the system and controller elements. The sensitivity analysis technique developed is based on the computation of the singular values and singular-value gradients of a feedback-control system. The method is applicable to single-input/single-output as well as multiloop continuous-control systems. Application to sampled-data systems is also explored. The sensitivity analysis technique was applied to a continuous yaw/roll damper stability augmentation system of a typical business jet, and the results show that the analysis is very useful in determining the system elements which have the largest effect on the relative stability of the closed-loop system. As a secondary product of the research reported here, the relative stability criteria based on the concept of singular values were explored.
Bazot, Marc; Daraï, Emile
2017-12-01
The aim of the present review was to evaluate the contribution of clinical examination and imaging techniques, mainly transvaginal sonography and magnetic resonance imaging (MRI) to diagnose deep infiltrating (DE) locations using prisma statement recommendations. Clinical examination has a relative low sensitivity and specificity to diagnose DE. Independently of DE locations, for all transvaginal sonography techniques a pooled sensitivity and specificity of 79% and 94% are observed approaching criteria for a triage test. Whatever the protocol and MRI devices, the pooled sensitivity and specificity for pelvic endometriosis diagnosis were 94% and 77%, respectively. For rectosigmoid endometriosis, pooled sensitivity and specificity of MRI were 92% and 96%, respectively fulfilling criteria of replacement test. In conclusion, advances in imaging techniques offer high sensitivity and specificity to diagnose DE with at least triage value and for rectosigmoid endometriosis replacement value imposing a revision of the concept of laparoscopy as the gold standard. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Li, Mingyan; Zuo, Zhentao; Jin, Jin; Xue, Rong; Trakic, Adnan; Weber, Ewald; Liu, Feng; Crozier, Stuart
2014-03-01
Parallel imaging (PI) is widely used for imaging acceleration by means of coil spatial sensitivities associated with phased array coils (PACs). By employing a time-division multiplexing technique, a single-channel rotating radiofrequency coil (RRFC) provides an alternative method to reduce scan time. Strategically combining these two concepts could provide enhanced acceleration and efficiency. In this work, the imaging acceleration ability and homogeneous image reconstruction strategy of 4-element rotating radiofrequency coil array (RRFCA) was numerically investigated and experimental validated at 7T with a homogeneous phantom. Each coil of RRFCA was capable of acquiring a large number of sensitivity profiles, leading to a better acceleration performance illustrated by the improved geometry-maps that have lower maximum values and more uniform distributions compared to 4- and 8-element stationary arrays. A reconstruction algorithm, rotating SENSitivity Encoding (rotating SENSE), was proposed to provide image reconstruction. Additionally, by optimally choosing the angular sampling positions and transmit profiles under the rotating scheme, phantom images could be faithfully reconstructed. The results indicate that, the proposed technique is able to provide homogeneous reconstructions with overall higher and more uniform signal-to-noise ratio (SNR) distributions at high reduction factors. It is hoped that, by employing the high imaging acceleration and homogeneous imaging reconstruction ability of RRFCA, the proposed method will facilitate human imaging for ultra high field MRI. Copyright © 2013 Elsevier Inc. All rights reserved.
Bhorade, S M; Sandesara, C; Garrity, E R; Vigneswaran, W T; Norwick, L; Alkan, S; Husain, A N; McCabe, M A; Yeldandi, V
2001-09-01
We prospectively compared the hybrid capture system (HCS) assay with conventional cell culture and shell vial assay for the detection of cytomegalovirus (CMV) infection and disease in the lung transplant population. Between January 1999 and February 2000, 34 lung transplant patients at Loyola University Medical Center, who were considered to be at risk for CMV disease, underwent surveillance testing for CMV cell culture, shell vial assay and HCS assay according to a pre-determined schedule. In addition, bronchoscopy with bronchoalveolar lavage (BAL) and transbronchial biopsy were performed at regular intervals and for clinical indications. All BAL samples were sent for CMV cultures and biopsy specimens were analyzed for histopathologic evidence of CMV by immunoperoxidase staining using antibody to early immediate nuclear antigen. Ten patients developed CMV disease/syndrome during the course of the study. The sensitivity, specificity, positive predictive value and negative predictive value were >90% for the HCS assay. The sensitivity of the HCS assay (90%) was statistically significantly higher than the sensitivity of either the SV assay (40%) or the cell culture (50%). In addition, the HCS assay was able to detect CMV 50 +/- 67 days prior to clinical evidence of CMV disease and an average of 36 days prior to the other detection techniques. The HCS assay is a sensitive diagnostic technique able to reliably detect CMV disease earlier than other diagnostic methods in the lung transplant population. Future studies may be able to evaluate whether pre-emptive anti-viral therapy targeted to specific viral loads using the HCS assay will be beneficial in preventing morbidity associated with CMV disease.
Wang, Yi; Li, Dongxun; Wang, Yan; Li, Kewei; Ye, Changyun
2016-01-19
Vibrio parahaemolyticus and Vibrio vulnificus are two marine seafood-borne pathogens causing severe illnesses in humans and aquatic animals. In this study, a recently developed novel multiple endonuclease restriction real-time loop-mediated isothermal amplification technology (MERT-LAMP) were successfully developed and evaluated for simultaneous detection of V. parahaemolyticus and V. vulnificus strains in only a single reaction. Two MERT-LAMP primer sets were designed to specifically target toxR gene of V. parahaemolyticus and rpoS gene of V. vulnificus. The MERT-LAMP reactions were conducted at 62 °C, and the positive results were produced in as short as 19 min with the genomic DNA templates extracted from the V. parahaemolyticus and V. vulnificus strains. The two target pathogens present in the same sample could be simultaneously detected and correctly differentiated based on distinct fluorescence curves in a real-time format. The sensitivity of MERT-LAMP assay was 250 fg and 125 fg DNA per reaction with genomic templates of V. parahaemolyticus and V. vulnificus strains, which was in conformity with conventional LAMP detection. Compared with PCR-based techniques, the MERT-LAMP technology was 100- and 10-fold more sensitive than that of PCR and qPCR methods. Moreover, the limit of detection of MERT-LAMP approach for V. parahaemolyticus isolates and V. vulnificus isolates detection in artificially-contaminated oyster samples was 92 CFU and 83 CFU per reaction. In conclusion, the MERT-LAMP assay presented here was a rapid, specific, and sensitive tool for the detection of V. parahaemolyticus and V. vulnificus, and could be adopted for simultaneous screening of V. parahaemolyticus and V. vulnificus in a wide variety of samples.
Rodríguez-Wong, Laura; Noguera-González, Danny; Esparza-Villalpando, Vicente; Montero-Aguilar, Mauricio
2017-01-01
Introduction The inferior alveolar nerve block (IANB) is the most common anesthetic technique used on mandibular teeth during root canal treatment. Its success in the presence of preoperative inflammation is still controversial. The aim of this study was to evaluate the sensitivity, specificity, predictive values, and accuracy of three diagnostic tests used to predict IANB failure in symptomatic irreversible pulpitis (SIP). Methodology A cross-sectional study was carried out on the mandibular molars of 53 patients with SIP. All patients received a single cartridge of mepivacaine 2% with 1 : 100000 epinephrine using the IANB technique. Three diagnostic clinical tests were performed to detect anesthetic failure. Anesthetic failure was defined as a positive painful response to any of the three tests. Sensitivity, specificity, predictive values, accuracy, and ROC curves were calculated and compared and significant differences were analyzed. Results IANB failure was determined in 71.7% of the patients. The sensitivity scores for the three tests (lip numbness, the cold stimuli test, and responsiveness during endodontic access) were 0.03, 0.35, and 0.55, respectively, and the specificity score was determined as 1 for all of the tests. Clinically, none of the evaluated tests demonstrated a high enough accuracy (0.30, 0.53, and 0.68 for lip numbness, the cold stimuli test, and responsiveness during endodontic access, resp.). A comparison of the areas under the curve in the ROC analyses showed statistically significant differences between the three tests (p < 0.05). Conclusion None of the analyzed tests demonstrated a high enough accuracy to be considered a reliable diagnostic tool for the prediction of anesthetic failure. PMID:28694714
Yamanaka, Takashi; Nemoto, Manabu; Bannai, Hiroshi; Tsujimura, Koji; Kondo, Takashi; Matsumura, Tomio; Gildea, Sarah; Cullinane, Ann
2016-03-01
Equine influenza (EI) is a highly contagious disease caused by viruses of the H3N8 subtype. The rapid diagnosis of EI is essential to reduce the disease spread. Many rapid antigen detection (RAD) tests for diagnosing human influenza are available, but their ability to diagnose EI has not been systematically evaluated. The aim of this study was to compare the performance of 22 RAD tests in the diagnosis of EI. The 22 RAD tests were performed on fivefold serial dilutions of EI virus to determine their detection limits. The four most sensitive RAD tests (ImmunoAce Flu, BD Flu examan, Quick chaser Flu A, B and ESPLINE Influenza A&B-N) were further evaluated using nasopharyngeal samples collected from experimentally infected and naturally infected horses. The results were compared to those obtained using molecular tests. The detection limits of the 22 RAD tests varied hugely. Even the four RAD tests showing the best sensitivity were 125-fold less sensitive than the molecular techniques. The duration of virus detection in the experimentally infected horses was shorter using the RAD tests than using the molecular techniques. The RAD tests detected between 27% and 73% of real-time RT-PCR-positive samples from naturally infected horses. The study demonstrated the importance of choosing the right RAD tests as only three of 22 were fit for diagnosing EI. It was also indicated that even RAD tests with the highest sensitivity serve only as an adjunct to molecular tests because of the potential for false-negative results. © 2015 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.
San Juan, R; Aguado, J M; López, M J; Lumbreras, C; Enriquez, F; Sanz, F; Chaves, F; López-Medrano, F; Lizasoain, M; Rufilanchas, J J
2005-03-01
Postsurgical mediastinitis (PSM) remains a major cause of morbidity and mortality in patients undergoing cardiac surgery procedures. Although prompt diagnosis is crucial in these patients, neither clinical data nor imaging techniques have shown enough sensitivity or specificity for early diagnosis of PSM. The aim of the present study was to assess the validity of blood cultures as a diagnostic test for the early detection of PSM in patients who become febrile after cardiac surgery procedures. During a 4-year period (1999-2002), patients who developed fever (>37.8 degrees C) in the first 60 days after a cardiac surgery procedure were evaluated. Blood cultures were drawn from these patients. PSM was defined as deep infection involving retrosternal tissue and/or the sternal bone directly observed by the surgeon and confirmed microbiologically. Three criteria for positivity of blood cultures were applied: bacteremia, staphylococcal bacteremia, or Staphylococcus aureus bacteremia. For purposes of the analysis, a positive blood culture in patients with PSM was considered a true-positive test and a negative blood culture a false-negative test. Otherwise, in febrile patients without PSM in the postsurgery period, a positive blood culture was considered a false-positive test and a negative blood culture a true-negative test. Blood cultures were drawn from 266 febrile patients in the postsurgery period. PSM occurred in 38 patients (26 cases due to S. aureus, 8 to Staphylococcus epidermidis, 3 to gram-negative enteric bacteria, and one to Pseudomonas aeruginosa). Within the 60-day postsurgical period, blood culture as a diagnostic test was most accurate in patients with S. aureus bacteremia, providing 68% sensitivity, 98% specificity, a positive predictive value of 87%, and a negative predictive value of 95%. If the analysis was limited to the period during which patients are at maximum risk for PSM (day 7-20), the values in patients with S. aureus bacteremia were as follows: 73% sensitivity, 98% specificity, 90% positive predictive value, and 93% negative predictive value. Blood culture is an accurate test for the early diagnosis of PSM in febrile patients after cardiac surgery, particularly in institutions where S. aureus is prevalent in this context. A negative blood culture practically excludes PSM and, during the period of maximum risk for PSM, the presence of S. aureus bacteremia should compel early surgical management.
Albertini, Emidio; Marconi, Gianpiero
2014-01-01
Methylation-sensitive amplified polymorphism (MSAP) is a technique developed for assessing the extent and pattern of cytosine methylation and has been applied to genomes of several species (Arabidopsis, grape, maize, tomato, and pepper). The technique relies on the use of isoschizomers that differ in their sensitivity to methylation.
ERIC Educational Resources Information Center
Walsh, Jeffrey A.; Braithwaite, Jeremy
2008-01-01
This work, drawing on the literature on alcohol consumption, sexual behavior, and researching sensitive topics, tests the efficacy of the unmatched-count technique (UCT) in establishing higher rates of truthful self-reporting when compared to traditional survey techniques. Traditional techniques grossly underestimate the scope of problems…
Matterwave interferometric velocimetry of cold Rb atoms
NASA Astrophysics Data System (ADS)
Carey, Max; Belal, Mohammad; Himsworth, Matthew; Bateman, James; Freegarde, Tim
2018-03-01
We consider the matterwave interferometric measurement of atomic velocities, which forms a building block for all matterwave inertial measurements. A theoretical analysis, addressing both the laboratory and atomic frames and accounting for residual Doppler sensitivity in the beamsplitter and recombiner pulses, is followed by an experimental demonstration, with measurements of the velocity distribution within a 20 ?K cloud of rubidium atoms. Our experiments use Raman transitions between the long-lived ground hyperfine states, and allow quadrature measurements that yield the full complex interferometer signal and hence discriminate between positive and negative velocities. The technique is most suitable for measurement of colder samples.
Matterwave interferometric velocimetry of cold Rb atoms
NASA Astrophysics Data System (ADS)
Carey, Max; Belal, Mohammad; Himsworth, Matthew; Bateman, James; Freegarde, Tim
2018-02-01
We consider the matterwave interferometric measurement of atomic velocities, which forms a building block for all matterwave inertial measurements. A theoretical analysis, addressing both the laboratory and atomic frames and accounting for residual Doppler sensitivity in the beamsplitter and recombiner pulses, is followed by an experimental demonstration, with measurements of the velocity distribution within a 20 $\\mu$K cloud of rubidium atoms. Our experiments use Raman transitions between the long-lived ground hyperfine states, and allow quadrature measurements that yield the full complex interferometer signal and hence discriminate between positive and negative velocities. The technique is most suitable for measurement of colder samples.
Veterinary extension on sampling techniques related to heartwater research.
Steyn, H C; McCrindle, C M E; Du Toit, D
2010-09-01
Heartwater, a tick-borne disease caused by Ehrlichia ruminantium, is considered to be a significant cause of mortality amongst domestic and wild ruminants in South Africa. The main vector is Amblyomma hebraeum and although previous epidemiological studies have outlined endemic areas based on mortalities, these have been limited by diagnostic methods which relied mainly on positive brain smears. The indirect fluorescent antibody test (IFA) has a low specificity for heartwater organisms as it cross-reacts with some other species. Since the advent of biotechnology and genomics, molecular epidemiology has evolved using the methodology of traditional epidemiology coupled with the new molecular techniques. A new quantitative real-time polymerase chain reaction (qPCR) test has been developed for rapid and accurate diagnosis of heartwater in the live animal. This method can also be used to survey populations of A. hebraeum ticks for heartwater. Sampling whole blood and ticks for this qPCR differs from routine serum sampling, which is used for many serological tests. Veterinary field staff, particularly animal health technicians, are involved in surveillance and monitoring of controlled and other diseases of animals in South Africa. However, it was found that the sampling of whole blood was not done correctly, probably because it is a new sampling technique specific for new technology, where the heartwater organism is much more labile than the serum antibodies required for other tests. This qPCR technique is highly sensitive and can diagnose heartwater in the living animal within 2 hours, in time to treat it. Poor sampling techniques that decrease the sensitivity of the test will, however, result in a false negative diagnosis. This paper describes the development of a skills training programme for para-veterinary field staff, to facilitate research into the molecular epidemiology of heartwater in ruminants and eliminate any sampling bias due to collection errors. Humane handling techniques were also included in the training, in line with the current focus on improved livestock welfare.
I Don’t Want to Come Back Down: Undoing versus Maintaining of Reward Recovery in Older Adolescents
Gilbert, Kirsten E.; Nolen-Hoeksema, Susan; Gruber, June
2017-01-01
Adolescence is characterized by heightened and sometimes impairing reward sensitivity, yet less is known about how adolescents recover from highly arousing positive states. This is particularly important given high onset rates of psychopathology associated with reward sensitivity during late adolescence and early adulthood. The current study thus utilized a novel reward sensitivity task in order to examine potential ways in which older adolescent females (ages 18–21; N = 83) might recover from high arousal positive reward sensitive states. Participants underwent a fixed incentive reward sensitivity task and subsequently watched a neutral, sad, or a low approach-motivated positive emotional film clip during which subjective and physiological recovery was assessed. Results indicated that the positive and negative film conditions were associated with maintained physiological arousal while the neutral condition facilitated faster physiological recovery from the reward sensitivity task. Interestingly, individual differences in self-reported positive emotion during the reward task were associated with faster recovery in the neutral condition. Findings suggest elicited emotion (regardless of valence) may serve to maintain reward sensitivity while self-reported positive emotional experience may be a key ingredient facilitating physiological recovery or undoing. Understanding the nuances of reward recovery provides a critical step in understanding the etiology and persistence of reward dysregulation more generally. PMID:26595439
Riboli, Danilo Flávio Moraes; Lyra, João César; Silva, Eliane Pessoa; Valadão, Luisa Leite; Bentlin, Maria Regina; Corrente, José Eduardo; Rugolo, Ligia Maria Suppo de Souza; da Cunha, Maria de Lourdes Ribeiro de Souza
2014-05-22
Catheter-related bloodstream infections (CR-BSIs) have become the most common cause of healthcare-associated bloodstream infections in neonatal intensive care units (ICUs). Microbiological evidence implicating catheters as the source of bloodstream infection is necessary to establish the diagnosis of CR-BSIs. Semi-quantitative culture is used to determine the presence of microorganisms on the external catheter surface, whereas quantitative culture also isolates microorganisms present inside the catheter. The main objective of this study was to determine the sensitivity and specificity of these two techniques for the diagnosis of CR-BSIs in newborns from a neonatal ICU. In addition, PFGE was used for similarity analysis of the microorganisms isolated from catheters and blood cultures. Semi-quantitative and quantitative methods were used for the culture of catheter tips obtained from newborns. Strains isolated from catheter tips and blood cultures which exhibited the same antimicrobial susceptibility profile were included in the study as positive cases of CR-BSI. PFGE of the microorganisms isolated from catheters and blood cultures was performed for similarity analysis and detection of clones in the ICU. A total of 584 catheter tips from 399 patients seen between November 2005 and June 2012 were analyzed. Twenty-nine cases of CR-BSI were confirmed. Coagulase-negative staphylococci (CoNS) were the most frequently isolated microorganisms, including S. epidermidis as the most prevalent species (65.5%), followed by S. haemolyticus (10.3%), yeasts (10.3%), K. pneumoniae (6.9%), S. aureus (3.4%), and E. coli (3.4%). The sensitivity of the semi-quantitative and quantitative techniques was 72.7% and 59.3%, respectively, and specificity was 95.7% and 94.4%. The diagnosis of CR-BSIs based on PFGE analysis of similarity between strains isolated from catheter tips and blood cultures showed 82.6% sensitivity and 100% specificity. The semi-quantitative culture method showed higher sensitivity and specificity for the diagnosis of CR-BSIs in newborns when compared to the quantitative technique. In addition, this method is easier to perform and shows better agreement with the gold standard, and should therefore be recommended for routine clinical laboratory use. PFGE may contribute to the control of CR-BSIs by identifying clusters of microorganisms in neonatal ICUs, providing a means of determining potential cross-infection between patients.
Measuring momentum for charged particle tomography
Morris, Christopher; Fraser, Andrew Mcleod; Schultz, Larry Joe; Borozdin, Konstantin N.; Klimenko, Alexei Vasilievich; Sossong, Michael James; Blanpied, Gary
2010-11-23
Methods, apparatus and systems for detecting charged particles and obtaining tomography of a volume by measuring charged particles including measuring the momentum of a charged particle passing through a charged particle detector. Sets of position sensitive detectors measure scattering of the charged particle. The position sensitive detectors having sufficient mass to cause the charged particle passing through the position sensitive detectors to scatter in the position sensitive detectors. A controller can be adapted and arranged to receive scattering measurements of the charged particle from the charged particle detector, determine at least one trajectory of the charged particle from the measured scattering; and determine at least one momentum measurement of the charged particle from the at least one trajectory. The charged particle can be a cosmic ray-produced charged particle, such as a cosmic ray-produced muon. The position sensitive detectors can be drift cells, such as gas-filled drift tubes.
Cointegration as a data normalization tool for structural health monitoring applications
NASA Astrophysics Data System (ADS)
Harvey, Dustin Y.; Todd, Michael D.
2012-04-01
The structural health monitoring literature has shown an abundance of features sensitive to various types of damage in laboratory tests. However, robust feature extraction in the presence of varying operational and environmental conditions has proven to be one of the largest obstacles in the development of practical structural health monitoring systems. Cointegration, a technique adapted from the field of econometrics, has recently been introduced to the SHM field as one solution to the data normalization problem. Response measurements and feature histories often show long-run nonstationarity due to fluctuating temperature, load conditions, or other factors that leads to the occurrence of false positives. Cointegration theory allows nonstationary trends common to two or more time series to be modeled and subsequently removed. Thus, the residual retains sensitivity to damage with dependence on operational and environmental variability removed. This study further explores the use of cointegration as a data normalization tool for structural health monitoring applications.
Study of 236U/238U ratio at CIRCE using a 16-strip silicon detector with a TOF system
NASA Astrophysics Data System (ADS)
De Cesare, M.; De Cesare, N.; D'Onofrio, A.; Gialanella, L.; Terrasi, F.
2015-04-01
Accelerator Mass Spectrometry (AMS) is presently the most sensitive technique for the measurement of long-lived actinides, e.g. 236U and xPu isotopes. A new actinide AMS system, based on a 3-MV pelletron tandem accelerator, is operated at the Center for Isotopic Research on Cultural and Environmental Heritage (CIRCE) in Caserta, Italy. In this paper we report on the procedure adopted to increase the 236U abundance sensitivity as low as possible. The energy and position determinations of the 236U ions, using a 16-strip silicon detector have been obtained. A 236U/238U isotopic ratio background level of about 2.9×10-11 was obtained, summing over all the strips, using a Time of Flight-Energy (TOF-E) system with a 16-strip silicon detector (4.9×10-12 just with one strip).
Optical detection of chemical warfare agents and toxic industrial chemicals
NASA Astrophysics Data System (ADS)
Webber, Michael E.; Pushkarsky, Michael B.; Patel, C. Kumar N.
2004-12-01
We present an analytical model evaluating the suitability of optical absorption based spectroscopic techniques for detection of chemical warfare agents (CWAs) and toxic industrial chemicals (TICs) in ambient air. The sensor performance is modeled by simulating absorption spectra of a sample containing both the target and multitude of interfering species as well as an appropriate stochastic noise and determining the target concentrations from the simulated spectra via a least square fit (LSF) algorithm. The distribution of the LSF target concentrations determines the sensor sensitivity, probability of false positives (PFP) and probability of false negatives (PFN). The model was applied to CO2 laser based photoacosutic (L-PAS) CWA sensor and predicted single digit ppb sensitivity with very low PFP rates in the presence of significant amount of interferences. This approach will be useful for assessing sensor performance by developers and users alike; it also provides methodology for inter-comparison of different sensing technologies.
A Magnetic Tracking System based on Highly Sensitive Integrated Hall Sensors
NASA Astrophysics Data System (ADS)
Schlageter, Vincent; Drljaca, Predrag; Popovic, Radivoje S.; KuČERA, Pavel
A tracking system with five degrees of freedom based on a 2D-array of 16 Hall sensors and a permanent magnet is presented in this paper. The sensitivity of the Hall sensors is increased by integrated micro- and external macro-flux-concentrators. Detection distance larger than 20cm (during one hour without calibration) is achieved using a magnet of 0.2cm3. This corresponds to a resolution of the sensors of 0.05µTrms. The position and orientation of the marker is displayed in real time at least 20 times per second. The sensing system is small enough to be hand-held and can be used in a normal environment. This presented tracking system has been successfully applied to follow a small swallowed magnet through the entire human digestive tube. This approach is extremely promising as a new non-invasive diagnostic technique in gastro-enterology.
Astrometric Search Method for Individually Resolvable Gravitational Wave Sources with Gaia
NASA Astrophysics Data System (ADS)
Moore, Christopher J.; Mihaylov, Deyan P.; Lasenby, Anthony; Gilmore, Gerard
2017-12-01
Gravitational waves (GWs) cause the apparent position of distant stars to oscillate with a characteristic pattern on the sky. Astrometric measurements (e.g., those made by Gaia) provide a new way to search for GWs. The main difficulty facing such a search is the large size of the data set; Gaia observes more than one billion stars. In this Letter the problem of searching for GWs from individually resolvable supermassive black hole binaries using astrometry is addressed for the first time; it is demonstrated how the data set can be compressed by a factor of more than 1 06, with a loss of sensitivity of less than 1%. This technique was successfully used to recover artificially injected GW signals from mock Gaia data and to assess the GW sensitivity of Gaia. Throughout the Letter the complementarity of Gaia and pulsar timing searches for GWs is highlighted.
Multidirectional flexible force sensors based on confined, self-adjusting carbon nanotube arrays
NASA Astrophysics Data System (ADS)
Lee, J.-I.; Pyo, Soonjae; Kim, Min-Ook; Kim, Jongbaeg
2018-02-01
We demonstrate a highly sensitive force sensor based on self-adjusting carbon nanotube (CNT) arrays. Aligned CNT arrays are directly synthesized on silicon microstructures by a space-confined growth technique which enables a facile self-adjusting contact. To afford flexibility and softness, the patterned microstructures with the integrated CNTs are embedded in polydimethylsiloxane structures. The sensing mechanism is based on variations in the contact resistance between the facing CNT arrays under the applied force. By finite element analysis, proper dimensions and positions for each component are determined. Further, high sensitivities up to 15.05%/mN of the proposed sensors were confirmed experimentally. Multidirectional sensing capability could also be achieved by designing multiple sets of sensing elements in a single sensor. The sensors show long-term operational stability, owing to the unique properties of the constituent CNTs, such as outstanding mechanical durability and elasticity.
In Vitro and In Vivo SERS Biosensing for Disease Diagnosis.
Moore, T Joshua; Moody, Amber S; Payne, Taylor D; Sarabia, Grace M; Daniel, Alyssa R; Sharma, Bhavya
2018-05-11
For many disease states, positive outcomes are directly linked to early diagnosis, where therapeutic intervention would be most effective. Recently, trends in disease diagnosis have focused on the development of label-free sensing techniques that are sensitive to low analyte concentrations found in the physiological environment. Surface-enhanced Raman spectroscopy (SERS) is a powerful vibrational spectroscopy that allows for label-free, highly sensitive, and selective detection of analytes through the amplification of localized electric fields on the surface of a plasmonic material when excited with monochromatic light. This results in enhancement of the Raman scattering signal, which allows for the detection of low concentration analytes, giving rise to the use of SERS as a diagnostic tool for disease. Here, we present a review of recent developments in the field of in vivo and in vitro SERS biosensing for a range of disease states including neurological disease, diabetes, cardiovascular disease, cancer, and viral disease.
NASA Astrophysics Data System (ADS)
Dhas, C. Ravi; Christy, A. Jennifer; Venkatesh, R.; Esther Santhoshi Monica, S.; Panda, Subhendu K.; Subramanian, B.; Ravichandran, K.; Sudhagar, P.; Raj, A. Moses Ezhil
2018-05-01
CuInAlS2 thin films for different substrate temperatures were deposited by a novel nebulizer spray technique. The polycrystalline CIAS thin film exhibited tetragonal structure with the preferential orientation of (1 1 2) plane. Nanoflakes were observed from the surface morphology of CIAS film. The peak position of core level spectra confirms the presence of CuInAlS2 from XPS analysis. The absorbance spectra and optical band gap were observed from the optical property. The activation energy, carrier concentration, hole mobility and resistivity were determined by linear four probe and Hall effect measurements. The CIAS film was used as a counter electrode (CE) in dye-sensitized solar cells (DSSCs) and is characterized by cyclic voltammetry, electrochemical impedance spectroscopy and Tafel measurements. DSSC fabricated with the CIAS CE achieved the photo conversion efficiency of about 2.55%.
Wang, Yan; Li, Hanyang; Zhao, Liyuan; Liu, Yongjun; Liu, Shuangqiang; Yang, Jun
2017-01-23
We demonstrate efficient coupling to the optical whispering gallery modes (WGMs) of nematic liquid crystal (NLC) microdroplets immersed in an immiscible aqueous environment. An individual NLC microdroplet, confined at the tip of a microcapillary, was coupled via a tapered optical fiber waveguide positioned correctly within its vicinity. Critical coupling of the taper-microdroplet system was facilitated by adjusting the gap between the taper and the microdroplet to change the overlap of the evanescent electromagnetic fields; efficient and controlled power transfer from the taper waveguide to the NLC microdroplet is indeed possible via the proposed technique. We also found that NLC microdroplets can function as highly sensitive thermal sensors: A maximum temperature sensitivity of 267.6 pm/°C and resolution of 7.5 × 10-2 °C were achieved in a 78-μm-diameter NLC microdroplet.
Pressure- and Temperature-Sensitive Paint at 0.3-m Transonic Cryogenic Tunnel
NASA Technical Reports Server (NTRS)
Watkins, A. Neal; Leighty, Bradley D.; Lipford, William E.; Goodman, Kyle Z.
2015-01-01
Recently both Pressure- and Temperature-Sensitive Paint experiments were conducted at cryogenic conditions in the 0.3-m Transonic Cryogenic Tunnel at NASA Langley Research Center. This represented a re-introduction of the techniques to the facility after more than a decade, and provided a means to upgrade the measurements using newer technology as well as demonstrate that the techniques were still viable in the facility. Temperature-Sensitive Paint was employed on a laminar airfoil for transition detection and Pressure-Sensitive Paint was employed on a supercritical airfoil. This report will detail the techniques and their unique challenges that need to be overcome in cryogenic environments. In addition, several optimization strategies will also be discussed.
Estimating Ocean Currents from Automatic Identification System Based Ship Drift Measurements
NASA Astrophysics Data System (ADS)
Jakub, Thomas D.
Ship drift is a technique that has been used over the last century and a half to estimate ocean currents. Several of the shortcomings of the ship drift technique include obtaining the data from multiple ships, the time delay in getting those ship positions to a data center for processing and the limited resolution based on the amount of time between position measurements. These shortcomings can be overcome through the use of the Automatic Identification System (AIS). AIS enables more precise ocean current estimates, the option of finer resolution and more timely estimates. In this work, a demonstration of the use of AIS to compute ocean currents is performed. A corresponding error and sensitivity analysis is performed to help identify under which conditions errors will be smaller. A case study in San Francisco Bay with constant AIS message updates was compared against high frequency radar and demonstrated ocean current magnitude residuals of 19 cm/s for ship tracks in a high signal to noise environment. These ship tracks were only minutes long compared to the normally 12 to 24 hour ship tracks. The Gulf of Mexico case study demonstrated the ability to estimate ocean currents over longer baselines and identified the dependency of the estimates on the accuracy of time measurements. Ultimately, AIS measurements when combined with ship drift can provide another method of estimating ocean currents, particularly when other measurements techniques are not available.