40 CFR 141.405 - Reporting and recordkeeping for ground water systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total-coliform positive samples that are not invalidated under § 141.21(c). Documentation...
40 CFR 141.405 - Reporting and recordkeeping for ground water systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total-coliform positive samples that are not invalidated under § 141.21(c). Documentation...
40 CFR 141.405 - Reporting and recordkeeping for ground water systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total-coliform positive samples that are not invalidated under § 141.21(c). Documentation...
40 CFR 141.405 - Reporting and recordkeeping for ground water systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total coliform-positive samples that are not invalidated under § 141.21(c) until March 31...
Code of Federal Regulations, 2013 CFR
2013-07-01
... REGULATIONS Revised Total Coliform Rule § 141.857 Routine monitoring requirements for public water systems... systems serving more than 1,000 persons. (2) Following any total coliform-positive sample taken under the... calendar month has been completed, systems must determine whether any coliform treatment technique triggers...
Metabolic power and energetic costs of professional Australian Football match-play.
Coutts, Aaron J; Kempton, Thomas; Sullivan, Courtney; Bilsborough, Johann; Cordy, Justin; Rampinini, Ermanno
2015-03-01
To compare the metabolic power demands between positional groups, and examine temporal changes in these parameters during Australian Football match-play. Longitudinal observational study. Global positioning system data were collected from 39 Australian Football players from the same club during 19 Australian Football League competition games over two seasons. A total of 342 complete match samples were obtained for analysis. Players were categorised into one of six positional groups: tall backs, mobile backs, midfielders, tall forwards, mobile forwards and rucks. Instantaneous raw velocity data obtained from the global positioning system units was exported to a customised spreadsheet which provided estimations of both speed-based (e.g. total and high-speed running distance) and derived metabolic power and energy expenditure variables (e.g. average metabolic power, high-power distance, total energy expenditure). There were significant differences between positional groups for both speed-based and metabolic power indices, with midfielders covering more total and high-speed distance, as well as greater average and overall energy expenditure compared to other positions (all p<0.001). There were reductions in total, high-speed, and high-power distance, as well as average metabolic power throughout the match (all p<0.001). Positional differences exist for both metabolic power and traditional running based variables. Generally, midfielders, followed by mobile forwards and mobile backs had greater activity profiles compared to other position groups. We observed that the reductions in most metabolic power variables during the course of the match are comparable to traditional running based metrics. This study demonstrates that metabolic power data may contribute to our understanding of the physical demands of Australian Football. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Toh, James Wei Tatt; Kim, Seon-Hahn
2017-11-04
We have previously reported our technique of single-docking totally robotic dissection for rectal cancer surgery using the Da Vinci ® Si Surgical System in 2009. However, we have since optimised our port placement for the Si system and have developed a novel configuration of port placement and docking for the Da Vinci ® Xi Surgical System. We have performed over 700 cases using this technique with the Si system and have used our Xi technique since 2016 for totally robotic dissection for rectal cancer. We have kept the configuration of port placements for both the Xi and Si system as similar as possible, with the priorities to avoid arm collisions as well as to provide a workable port configuration of two left-handed instruments and one right-handed instrument. To date, there have had no major complications or arm collisions related to this technique of docking, port positioning and instrument placement.
Statistical Aspects of Reliability, Maintainability, and Availability.
1987-10-01
A total of 33 research reports were issued, and 35 papers were published in scientific journals or are in press. Research topics included optimal assembly of systems, multistate system theory , testing whether new is better than used nonparameter survival function estimation measuring information in censored models, generalizations of total positively and
Automatic Mesh Generation of Hybrid Mesh on Valves in Multiple Positions in Feedline Systems
NASA Technical Reports Server (NTRS)
Ross, Douglass H.; Ito, Yasushi; Dorothy, Fredric W.; Shih, Alan M.; Peugeot, John
2010-01-01
Fluid flow simulations through a valve often require evaluation of the valve in multiple opening positions. A mesh has to be generated for the valve for each position and compounding. The problem is the fact that the valve is typically part of a larger feedline system. In this paper, we propose to develop a system to create meshes for feedline systems with parametrically controlled valve openings. Herein we outline two approaches to generate the meshes for a valve in a feedline system at multiple positions. There are two issues that must be addressed. The first is the creation of the mesh on the valve for multiple positions. The second is the generation of the mesh for the total feedline system including the valve. For generation of the mesh on the valve, we will describe the use of topology matching and mesh generation parameter transfer. For generation of the total feedline system, we will describe two solutions that we have implemented. In both cases the valve is treated as a component in the feedline system. In the first method the geometry of the valve in the feedline system is replaced with a valve at a different opening position. Geometry is created to connect the valve to the feedline system. Then topology for the valve is created and the portion of the topology for the valve is topology matched to the standard valve in a different position. The mesh generation parameters are transferred and then the volume mesh for the whole feedline system is generated. The second method enables the user to generate the volume mesh on the valve in multiple open positions external to the feedline system, to insert it into the volume mesh of the feedline system, and to reduce the amount of computer time required for mesh generation because only two small volume meshes connecting the valve to the feedline mesh need to be updated.
Employee Engagement and a Culture of Safety in the Intensive Care Unit.
Collier, Susan L; Fitzpatrick, Joyce J; Siedlecki, Sandra L; Dolansky, Mary A
2016-01-01
A descriptive, retrospective design was used to explore the relationship between employee engagement and culture of safety in ICUs within a large Midwestern healthcare system. Results demonstrated a strong positive relationship between total engagement score and total patient safety score (r = 0.645, P < .01) and positive relationships between total engagement score and the 12 safety culture dimensions. These findings have implications for improving managerial strategies relative to employee engagement that may ultimately impact perceptions of a safety culture.
Full Ionisation In Binary-Binary Encounters With Small Positive Energies
NASA Astrophysics Data System (ADS)
Sweatman, W. L.
2006-08-01
Interactions between binary stars and single stars and binary stars and other binary stars play a key role in the dynamics of a dense stellar system. Energy can be transferred between the internal dynamics of a binary and the larger scale dynamics of the interacting objects. Binaries can be destroyed and created by the interaction. In a binary-binary encounter, full ionisation occurs when both of the binary stars are destroyed in the interaction to create four single stars. This is only possible when the total energy of the system is positive. For very small energies the probability of this occurring is very low and it tends towards zero as the total energy tends towards zero. Here the case is considered for which all the stars have equal masses. An asymptotic power law is predicted relating the probability of full ionisation with the total energy when this latter quantity is small. The exponent, which is approximately 2.31, is compared with the results from numerical scattering experiments. The theoretical approach taken is similar to one used previously in the three-body problem. It makes use of the fact that the most dramatic changes in scale and energies of a few-body system occur when its components pass near to a central configuration. The position, and number, of these configurations is not known for the general four-body problem, however, with equal masses there are known to be exactly five different cases. Separate consideration and comparison of the properties of orbits close to each of these five central configurations enables the prediction of the form of the cross-section for full ionisation for the case of small positive total energy. This is the relation between total energy and the probability of total ionisation described above.
Goutziana, Georgia; Mouchtouri, Varvara A; Karanika, Maria; Kavagias, Antonios; Stathakis, Nikolaos E; Gourgoulianis, Kostantinos; Kremastinou, Jenny; Hadjichristodoulou, Christos
2008-01-01
Background Legionnaires' disease continues to be a public health concern in passenger ships. This study was scheduled in order to investigate Legionella spp. colonization of water distribution systems (WDS), recreational pools, and air-conditioning systems on board ferries and cruise ships in an attempt to identify risk factors for Legionella spp. colonization associated with ship water systems and water characteristics. Methods Water systems of 21 ferries and 10 cruise ships including WDS, air conditioning systems and pools were investigated for the presence of Legionella spp. Results The 133 samples collected from the 10 cruise ships WDS, air conditioning systems and pools were negative for Legionella spp. Of the 21 ferries WDS examined, 14 (66.7%) were legionellae-positive. A total of 276 samples were collected from WDS and air conditioning systems. Legionella spp. was isolated from 37.8% of the hot water samples and 17.5% of the cold water samples. Of the total 96 positive isolates, 87 (90.6%) were L. pneumophila. Legionella spp. colonization was positively associated with ship age. The temperature of the hot water samples was negatively associated with colonization of L. pneumophila serogroup (sg) 1 and that of L. pneumophila sg 2 to 14. Increases in pH ≥7.8 and total plate count ≥400 CFU/L, correlated positively with the counts of L. pneumophila sg 2 to 14 and Legionella spp. respectively. Free chlorine of ≥0.2 mg/L inhibited colonization of Legionella spp. Conclusion WDS of ferries can be heavily colonized by Legionella spp. and may present a risk of Legionnaires' disease for passengers and crew members. Guidelines and advising of Legionnaires' disease prevention regarding ferries are needed, in particular for operators and crew members. PMID:19025638
Goutziana, Georgia; Mouchtouri, Varvara A; Karanika, Maria; Kavagias, Antonios; Stathakis, Nikolaos E; Gourgoulianis, Kostantinos; Kremastinou, Jenny; Hadjichristodoulou, Christos
2008-11-24
Legionnaires' disease continues to be a public health concern in passenger ships. This study was scheduled in order to investigate Legionella spp. colonization of water distribution systems (WDS), recreational pools, and air-conditioning systems on board ferries and cruise ships in an attempt to identify risk factors for Legionella spp. colonization associated with ship water systems and water characteristics. Water systems of 21 ferries and 10 cruise ships including WDS, air conditioning systems and pools were investigated for the presence of Legionella spp. The 133 samples collected from the 10 cruise ships WDS, air conditioning systems and pools were negative for Legionella spp. Of the 21 ferries WDS examined, 14 (66.7%) were legionellae-positive. A total of 276 samples were collected from WDS and air conditioning systems. Legionella spp. was isolated from 37.8% of the hot water samples and 17.5% of the cold water samples. Of the total 96 positive isolates, 87 (90.6%) were L. pneumophila. Legionella spp. colonization was positively associated with ship age. The temperature of the hot water samples was negatively associated with colonization of L. pneumophila serogroup (sg) 1 and that of L. pneumophila sg 2 to 14. Increases in pH >/=7.8 and total plate count > or =400 CFU/L, correlated positively with the counts of L. pneumophila sg 2 to 14 and Legionella spp. respectively. Free chlorine of > or =0.2 mg/L inhibited colonization of Legionella spp. WDS of ferries can be heavily colonized by Legionella spp. and may present a risk of Legionnaires' disease for passengers and crew members. Guidelines and advising of Legionnaires' disease prevention regarding ferries are needed, in particular for operators and crew members.
A Non-Contact Measurement System for the Range of Motion of the Hand
Pham, Trieu; Pathirana, Pubudu N.; Trinh, Hieu; Fay, Pearse
2015-01-01
An accurate and standardised tool to measure the active range of motion (ROM) of the hand is essential to any progressive assessment scenario in hand therapy practice. Goniometers are widely used in clinical settings for measuring the ROM of the hand. However, such measurements have limitations with regard to inter-rater and intra-rater reliability and involve direct physical contact with the hand, possibly increasing the risk of transmitting infections. The system proposed in this paper is the first non-contact measurement system utilising Intel Perceptual Technology and a Senz3D Camera for measuring phalangeal joint angles. To enhance the accuracy of the system, we developed a new approach to achieve the total active movement without measuring three joint angles individually. An equation between the actual spacial position and measurement value of the proximal inter-phalangeal joint was established through the measurement values of the total active movement, so that its actual position can be inferred. Verified by computer simulations, experimental results demonstrated a significant improvement in the calculation of the total active movement and successfully recovered the actual position of the proximal inter-phalangeal joint angles. A trial that was conducted to examine the clinical applicability of the system involving 40 healthy subjects confirmed the practicability and consistency in the proposed system. The time efficiency conveyed a stronger argument for this system to replace the current practice of using goniometers. PMID:26225976
Addressing the Influence of Space Weather on Airline Navigation
NASA Technical Reports Server (NTRS)
Sparks, Lawrence
2012-01-01
The advent of satellite-based augmentation systems has made it possible to navigate aircraft safely using radio signals emitted by global navigation satellite systems (GNSS) such as the Global Positioning System. As a signal propagates through the earth's ionosphere, it suffers delay that is proportional to the total electron content encountered along the raypath. Since the magnitude of this total electron content is strongly influenced by space weather, the safety and reliability of GNSS for airline navigation requires continual monitoring of the state of the ionosphere and calibration of ionospheric delay. This paper examines the impact of space weather on GNSS-based navigation and provides an overview of how the Wide Area Augmentation System protects its users from positioning error due to ionospheric disturbances
Henninger, Heath B; King, Frank K; Tashjian, Robert Z; Burks, Robert T
2014-05-01
Numerous studies have examined the biomechanics of isolated variables in reverse total shoulder arthroplasty. This study directly compared the composite performance of two reverse total shoulder arthroplasty systems; each system was designed around either a medialized or a lateralized glenohumeral center of rotation. Seven pairs of shoulders were tested on a biomechanical simulator. Center of rotation, position of the humerus, passive and active range of motion, and force to abduct the arm were quantified. Native arms were tested, implanted with a Tornier Aequalis or DJO Surgical Reverse Shoulder Prosthesis (RSP), and then retested. Differences from the native state were then documented. Both systems shifted the center of rotation medially and inferiorly relative to native. Medial shifts were greater in the Aequalis implant (P < .037). All humeri shifted inferior compared with native but moved medially with the Aequalis (P < .001). Peak passive abduction, internal rotation, and external rotation did not differ between systems (P > .05). Both reverse total shoulder arthroplasty systems exhibited adduction deficits, but the RSP implant deficit was smaller (P = .046 between implants). Both systems reduced forces to abduct the arm compared with native, although the Aequalis required more force to initiate motion from the resting position (P = .022). Given the differences in system designs and configurations, outcome variables were generally comparable. The RSP implant allowed slightly more adduction, had a more lateralized humeral position, and required less force to initiate elevation. These factors may play roles in limiting scapular notching, improving active external rotation by normalizing the residual rotator cuff length, and limiting excessive stress on the deltoid. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
The Evolution of Computer-Assisted Total Hip Arthroplasty and Relevant Applications.
Chang, Jun-Dong; Kim, In-Sung; Bhardwaj, Atul M; Badami, Ramachandra N
2017-03-01
In total hip arthroplasty (THA), the accurate positioning of implants is the key to achieve a good clinical outcome. Computer-assisted orthopaedic surgery (CAOS) has been developed for more accurate positioning of implants during the THA. There are passive, semi-active, and active systems in CAOS for THA. Navigation is a passive system that only provides information and guidance to the surgeon. There are 3 types of navigation: imageless navigation, computed tomography (CT)-based navigation, and fluoroscopy-based navigation. In imageless navigation system, a new method of registration without the need to register the anterior pelvic plane was introduced. CT-based navigation can be efficiently used for pelvic plane reference, the functional pelvic plane in supine which adjusts anterior pelvic plane sagittal tilt for targeting the cup orientation. Robot-assisted system can be either active or semi-active. The active robotic system performs the preparation for implant positioning as programmed preoperatively. It has been used for only femoral implant cavity preparation. Recently, program for cup positioning was additionally developed. Alternatively, for ease of surgeon acceptance, semi-active robot systems are developed. It was initially applied only for cup positioning. However, with the development of enhanced femoral workflows, this system can now be used to position both cup and stem. Though there have been substantial advancements in computer-assisted THA, its use can still be controversial at present due to the steep learning curve, intraoperative technical issues, high cost and etc. However, in the future, CAOS will certainly enable the surgeon to operate more accurately and lead to improved outcomes in THA as the technology continues to evolve rapidly.
High Efficiency, Low EMI and Positioning Tolerant Wireless Charging of EVs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chabaan, Rakan
The objective of this project is to develop, implement, and demonstrate a wireless power transfer (WPT) system that is capable of the following metrics: Total system efficiencies of more than 85 percent with minimum 20 cm coil-to-coil gap; System output power at least 6.6 kW; but design system up to 19.2 kW for future higher power study; Maximum lateral positioning tolerance achievable while meeting regulatory emission guidelines.
Schumacher, Loni L; Huss, Anne R; Cochrane, Roger A; Stark, Charles R; Woodworth, Jason C; Bai, Jianfa; Poulsen, Elizabeth G; Chen, Qi; Main, Rodger G; Zhang, Jianqiang; Gauger, Phillip C; Ramirez, Alejandro; Derscheid, Rachel J; Magstadt, Drew M; Dritz, Steve S; Jones, Cassandra K
2017-01-01
New regulatory and consumer demands highlight the importance of animal feed as a part of our national food safety system. Porcine epidemic diarrhea virus (PEDV) is the first viral pathogen confirmed to be widely transmissible in animal food. Because the potential for viral contamination in animal food is not well characterized, the objectives of this study were to 1) observe the magnitude of virus contamination in an animal food manufacturing facility, and 2) investigate a proposed method, feed sequencing, to decrease virus decontamination on animal food-contact surfaces. A U.S. virulent PEDV isolate was used to inoculate 50 kg swine feed, which was mixed, conveyed, and discharged into bags using pilot-scale feed manufacturing equipment. Surfaces were swabbed and analyzed for the presence of PEDV RNA by quantitative real-time polymerase chain reaction (qPCR). Environmental swabs indicated complete contamination of animal food-contact surfaces (0/40 vs. 48/48, positive baseline samples/total baseline samples, positive subsequent samples/total subsequent samples, respectively; P < 0.05) and near complete contamination of non-animal food-contact surfaces (0/24 vs. 16/18, positive baseline samples/total baseline samples, positive subsequent samples/total subsequent samples, respectively; P < 0.05). Flushing animal food-contact surfaces with low-risk feed is commonly used to reduce cross-contamination in animal feed manufacturing. Thus, four subsequent 50 kg batches of virus-free swine feed were manufactured using the same system to test its impact on decontaminating animal food-contact surfaces. Even after 4 subsequent sequences, animal food-contact surfaces retained viral RNA (28/33 positive samples/total samples), with conveying system being more contaminated than the mixer. A bioassay to test infectivity of dust from animal food-contact surfaces failed to produce infectivity. This study demonstrates the potential widespread viral contamination of surfaces in an animal food manufacturing facility and the difficulty of removing contamination using conventional feed sequencing, which underscores the importance for preventing viruses from entering and contaminating such facilities.
Match-play demands of elite youth Gaelic football using global positioning system tracking.
Reilly, Brian; Akubat, Ibrahim; Lyons, Mark; Collins, D Kieran
2015-04-01
Global positioning systems (GPS) technology has made athlete-tracking a convenient and accepted technique to specify movement patterns and physical demands in sport. The purpose of this study was to examine positional demands of elite youth Gaelic football match-play using portable GPS technology to examine movement patterns and heart rates across match periods. Fifty-six elite youth male Gaelic footballers (age, 15 ± 0.66 years) fitted with portable 4-Hz GPS units were observed during 6 competitive matches (60 minutes). Data provided from the GPS unit included total distance, high-intensity (≥17·km·h(-1)) distance, sprint (≥22 km·h(-1)) distance, and total number of sprints. Heart rate was monitored continuously throughout the games. Players covered a mean distance of 5732 ± 1047 m, and the mean intensity of match-play was 85% of the peak heart rate. There was a significant (p = 0.028) drop in the total distance covered in the second half (2783 ± 599 m) compared with the first half (2948 ± 580 m). In particular, there is a noticeable drop in the distance covered in the third quarter of the game (after half-time), which has implications for re-warming up at the end of the half-time interval. There was a highly significant (p < .001) difference in the distance traveled across the 5 positional groups with midfielders covering the greatest total distance (6740 ± 384 m). The significant differences found with respect to positional groups support the implementation of individual, position-specific strength and conditioning programs.
A New Blondin System for Surveying and Photogrammetry
Cuesta, Federico; Lopez-Rodriguez, Francisco M.; Esteban, Antonio
2013-01-01
The main objective of the system presented in this paper is to provide surveyors and engineers with a new photogrammetry device that can be easily integrated with surveying total stations and a global navigation satellite system (GNSS) infrastructure at a construction site, taking advantage of their accuracy and overcoming limitations of aerial vehicles with respect to weight, autonomy and skilled operator requirements in aerial photogrammetry. The system moves between two mounting points, in a blondin ropeway configuration, at the construction site, taking pictures and recording the data of the position and the orientation along the cable path. A cascaded extended Kalman filter is used to integrate measurements from the on-board inertial measurement unit (IMU), a GPS and a GNSS. Experimental results taken in a construction site show the system performance, including the validation of the position estimation, with a robotic surveying total station, or the creation of a digital surface model (DSM), using the emergent structure from motion (SfM) techniques and open software. The georeferencing of the DSM is performed based on estimated camera position or using ground control points (GCPs).
Lin, Jiarui; Gao, Kai; Gao, Yang; Wang, Zheng
2017-10-01
In order to detect the position of the cutting shield at the head of a double shield tunnel boring machine (TBM) during the excavation, this paper develops a combined measurement system which is mainly composed of several optical feature points, a monocular vision sensor, a laser target sensor, and a total station. The different elements of the combined system are mounted on the TBM in suitable sequence, and the position of the cutting shield in the reference total station frame is determined by coordinate transformations. Subsequently, the structure of the feature points and matching technique for them are expounded, the position measurement method based on monocular vision is presented, and the calibration methods for the unknown relationships among different parts of the system are proposed. Finally, a set of experimental platforms to simulate the double shield TBM is established, and accuracy verification experiments are conducted. Experimental results show that the mean deviation of the system is 6.8 mm, which satisfies the requirements of double shield TBM guidance.
Nurse staffing levels and Medicaid reimbursement rates in nursing facilities.
Harrington, Charlene; Swan, James H; Carrillo, Helen
2007-06-01
To examine the relationship between nursing staffing levels in U.S. nursing homes and state Medicaid reimbursement rates. Facility staffing, characteristics, and case-mix data were from the federal On-Line Survey Certification and Reporting (OSCAR) system and other data were from public sources. Ordinary least squares and two-stage least squares regression analyses were used to separately examine the relationship between registered nurse (RN) and total nursing hours in all U.S. nursing homes in 2002, with two endogenous variables: Medicaid reimbursement rates and resident case mix. RN hours and total nursing hours were endogenous with Medicaid reimbursement rates and resident case mix. As expected, Medicaid nursing home reimbursement rates were positively related to both RN and total nursing hours. Resident case mix was a positive predictor of RN hours and a negative predictor of total nursing hours. Higher state minimum RN staffing standards was a positive predictor of RN and total nursing hours while for-profit facilities and the percent of Medicaid residents were negative predictors. To increase staffing levels, average Medicaid reimbursement rates would need to be substantially increased while higher state minimum RN staffing standards is a stronger positive predictor of RN and total nursing hours.
Accuracy Analysis of a Wireless Indoor Positioning System Using Geodetic Methods
NASA Astrophysics Data System (ADS)
Wagner, Przemysław; Woźniak, Marek; Odziemczyk, Waldemar; Pakuła, Dariusz
2017-12-01
Ubisense RTLS is one of the Indoor positioning systems using an Ultra Wide Band. AOA and TDOA methods are used as a principle of positioning. The accuracy of positioning depends primarily on the accuracy of determined angles and distance differences. The paper presents the results of accuracy research which includes a theoretical accuracy prediction and a practical test. Theoretical accuracy was calculated for two variants of system components geometry, assuming the parameters declared by the system manufacturer. Total station measurements were taken as a reference during the practical test. The results of the analysis are presented in a graphical form. A sample implementation (MagMaster) developed by Globema is presented in the final part of the paper.
Positive affect and psychobiological processes
Dockray, Samantha; Steptoe, Andrew
2010-01-01
Positive affect has been associated with favourable health outcomes, and it is likely that several biological processes mediate the effects of positive mood on physical health. There is converging evidence that positive affect activates the neuroendocrine, autonomic and immune systems in distinct and functionally meaningful ways. Cortisol, both total output and the awakening response, has consistently been shown to be lower among individuals with higher levels of positive affect. The beneficial effects of positive mood on cardiovascular function, including heart rate and blood pressure, and the immune system have also been described. The influence of positive affect on these psychobiological processes are independent of negative affect, suggesting that positive affect may have characteristic biological correlates. The duration and conceptualisation of positive affect may be important considerations in understanding how different biological systems are activated in association with positive affect. The association of positive affect and psychobiological processes has been established, and these biological correlates may be partly responsible for the protective effects of positive affect on health outcomes. PMID:20097225
The Evolution of Computer-Assisted Total Hip Arthroplasty and Relevant Applications
Kim, In-Sung; Bhardwaj, Atul M.; Badami, Ramachandra N.
2017-01-01
In total hip arthroplasty (THA), the accurate positioning of implants is the key to achieve a good clinical outcome. Computer-assisted orthopaedic surgery (CAOS) has been developed for more accurate positioning of implants during the THA. There are passive, semi-active, and active systems in CAOS for THA. Navigation is a passive system that only provides information and guidance to the surgeon. There are 3 types of navigation: imageless navigation, computed tomography (CT)-based navigation, and fluoroscopy-based navigation. In imageless navigation system, a new method of registration without the need to register the anterior pelvic plane was introduced. CT-based navigation can be efficiently used for pelvic plane reference, the functional pelvic plane in supine which adjusts anterior pelvic plane sagittal tilt for targeting the cup orientation. Robot-assisted system can be either active or semi-active. The active robotic system performs the preparation for implant positioning as programmed preoperatively. It has been used for only femoral implant cavity preparation. Recently, program for cup positioning was additionally developed. Alternatively, for ease of surgeon acceptance, semi-active robot systems are developed. It was initially applied only for cup positioning. However, with the development of enhanced femoral workflows, this system can now be used to position both cup and stem. Though there have been substantial advancements in computer-assisted THA, its use can still be controversial at present due to the steep learning curve, intraoperative technical issues, high cost and etc. However, in the future, CAOS will certainly enable the surgeon to operate more accurately and lead to improved outcomes in THA as the technology continues to evolve rapidly. PMID:28316957
A Graphical Proof of the Positive Entropy Change in Heat Transfer between Two Objects
ERIC Educational Resources Information Center
Kiatgamolchai, Somchai
2015-01-01
It is well known that heat transfer between two objects results in a positive change in the total entropy of the two-object system. The second law of thermodynamics states that the entropy change of a naturally irreversible process is positive. In other words, if the entropy change of any process is positive, it can be inferred that such a process…
Autonomous GPS/INS navigation experiment for Space Transfer Vehicle
NASA Technical Reports Server (NTRS)
Upadhyay, Triveni N.; Cotterill, Stephen; Deaton, A. W.
1993-01-01
An experiment to validate the concept of developing an autonomous integrated spacecraft navigation system using on board Global Positioning System (GPS) and Inertial Navigation System (INS) measurements is described. The feasibility of integrating GPS measurements with INS measurements to provide a total improvement in spacecraft navigation performance, i.e. improvement in position, velocity and attitude information, was previously demonstrated. An important aspect of this research is the automatic real time reconfiguration capability of the system designed to respond to changes in a spacecraft mission under the control of an expert system.
Autonomous GPS/INS navigation experiment for Space Transfer Vehicle (STV)
NASA Technical Reports Server (NTRS)
Upadhyay, Triveni N.; Cotterill, Stephen; Deaton, A. Wayne
1991-01-01
An experiment to validate the concept of developing an autonomous integrated spacecraft navigation system using on board Global Positioning System (GPS) and Inertial Navigation System (INS) measurements is described. The feasibility of integrating GPS measurements with INS measurements to provide a total improvement in spacecraft navigation performance, i.e. improvement in position, velocity and attitude information, was previously demonstrated. An important aspect of this research is the automatic real time reconfiguration capability of the system designed to respond to changes in a spacecraft mission under the control of an expert system.
Autonomous GPS/INS navigation experiment for Space Transfer Vehicle
NASA Astrophysics Data System (ADS)
Upadhyay, Triveni N.; Cotterill, Stephen; Deaton, A. W.
1993-07-01
An experiment to validate the concept of developing an autonomous integrated spacecraft navigation system using on board Global Positioning System (GPS) and Inertial Navigation System (INS) measurements is described. The feasibility of integrating GPS measurements with INS measurements to provide a total improvement in spacecraft navigation performance, i.e. improvement in position, velocity and attitude information, was previously demonstrated. An important aspect of this research is the automatic real time reconfiguration capability of the system designed to respond to changes in a spacecraft mission under the control of an expert system.
High accuracy autonomous navigation using the global positioning system (GPS)
NASA Technical Reports Server (NTRS)
Truong, Son H.; Hart, Roger C.; Shoan, Wendy C.; Wood, Terri; Long, Anne C.; Oza, Dipak H.; Lee, Taesul
1997-01-01
The application of global positioning system (GPS) technology to the improvement of the accuracy and economy of spacecraft navigation, is reported. High-accuracy autonomous navigation algorithms are currently being qualified in conjunction with the GPS attitude determination flyer (GADFLY) experiment for the small satellite technology initiative Lewis spacecraft. Preflight performance assessments indicated that these algorithms are able to provide a real time total position accuracy of better than 10 m and a velocity accuracy of better than 0.01 m/s, with selective availability at typical levels. It is expected that the position accuracy will be increased to 2 m if corrections are provided by the GPS wide area augmentation system.
NASA Astrophysics Data System (ADS)
Chen, C.-H.; Tan, T. Y.
1995-10-01
Using the theoretically calculated point-defect total-energy values of Baraff and Schlüter in GaAs, an amphoteric-defect model has been proposed by Walukiewicz to explain a large number of experimental results. The suggested amphoteric-defect system consists of two point-defect species capable of transforming into each other: the doubly negatively charged Ga vacancy V {Ga/2-} and the triply positively charged defect complex (ASGa+ V As)3+, with AsGa being the antisite defect of an As atom occupying a Ga site and V As being an As vacancy. When present in sufficiently high concentrations, the amphoteric defect system V {Ga/2-}/(AsGa+ V As)3+ is supposed to be able to pin the GaAs Fermi level at approximately the E v +0.6 eV level position, which requires that the net free energy of the V Ga/(AsGa+ V As) defect system to be minimum at the same Fermi-level position. We have carried out a quantitative study of the net energy of this defect system in accordance with the individual point-defect total-energy results of Baraff and Schlüter, and found that the minimum net defect-system-energy position is located at about the E v +1.2 eV level position instead of the needed E v +0.6 eV position. Therefore, the validity of the amphoteric-defect model is in doubt. We have proposed a simple criterion for determining the Fermi-level pinning position in the deeper part of the GaAs band gap due to two oppositely charged point-defect species, which should be useful in the future.
Norton, D M; McCamey, M; Boor, K J; Wiedmann, M
2000-03-01
The cold-smoked fish industry was used as a model for the development of a system for monitoring Listeria spp. in foods and in the food processing environment. A total of 214 samples including raw fish, fish during the cold-smoking process, finished product, and environmental samples were collected from three processing facilities over two visits to each facility. Samples were screened for Listeria spp. using the BAX for Screening/genus Listeria polymerase chain reaction system (PCR) and by culture. Listeria spp., confirmed by the API Listeria test strip or by a PCR assay targeting the L. monocytogenes hlyA gene, were isolated from a total of 89 (41.6%) samples. Of these, 80 samples also tested positive for Listeria spp. using the BAX system. Specifically, 42 (55.3%) environmental samples (n = 76), 11 (25.6%) raw materials samples (n = 43), 20 (35.1%) samples from fish in various stages of processing (n = 57), and 7 (18.4%) finished product samples (n = 38) tested positive for Listeria spp. using the BAX system. Five (4.0%) of the 125 culture-negative samples yielded BAX system-positive results. Listeria isolates from each of nine culture-positive/BAX system-negative samples yielded a positive reaction when tested in pure culture by the BAX system, suggesting that our false-negative results were likely due to the presence of low Listeria numbers in the initial enrichment as opposed to nonreacting isolates. The employment of alternative enrichment protocols, such as the two-step enrichment recommended by the manufacturer, may increase the sensitivity of the assay.
Pe’eri, Shachak; Thein, May-Win; Rzhanov, Yuri; Celikkol, Barbaros; Swift, M. Robinson
2017-01-01
This paper presents a proof-of-concept optical detector array sensor system to be used in Unmanned Underwater Vehicle (UUV) navigation. The performance of the developed optical detector array was evaluated for its capability to estimate the position, orientation and forward velocity of UUVs with respect to a light source fixed in underwater. The evaluations were conducted through Monte Carlo simulations and empirical tests under a variety of motion configurations. Monte Carlo simulations also evaluated the system total propagated uncertainty (TPU) by taking into account variations in the water column turbidity, temperature and hardware noise that may degrade the system performance. Empirical tests were conducted to estimate UUV position and velocity during its navigation to a light beacon. Monte Carlo simulation and empirical results support the use of the detector array system for optics based position feedback for UUV positioning applications. PMID:28758936
Messner, Michael J; Berger, Philip; Javier, Julie
2017-06-01
Public water systems (PWSs) in the United States generate total coliform (TC) and Escherichia coli (EC) monitoring data, as required by the Total Coliform Rule (TCR). We analyzed data generated in 2011 by approximately 38,000 small (serving fewer than 4101 individuals) undisinfected public water systems (PWSs). We used statistical modeling to characterize a distribution of TC detection probabilities for each of nine groupings of PWSs based on system type (community, non-transient non-community, and transient non-community) and population served (less than 101, 101-1000 and 1001-4100 people). We found that among PWS types sampled in 2011, on average, undisinfected transient PWSs test positive for TC 4.3% of the time as compared with 3% for undisinfected non-transient PWSs and 2.5% for undisinfected community PWSs. Within each type of PWS, the smaller systems have higher median TC detection than the larger systems. All TC-positive samples were assayed for EC. Among TC-positive samples from small undisinfected PWSs, EC is detected in about 5% of samples, regardless of PWS type or size. We evaluated the upper tail of the TC detection probability distributions and found that significant percentages of some system types have high TC detection probabilities. For example, assuming the systems providing data are nationally-representative, then 5.0% of the ∼50,000 small undisinfected transient PWSs in the U.S. have TC detection probabilities of 20% or more. Communities with such high TC detection probabilities may have elevated risk of acute gastrointestinal (AGI) illness - perhaps as great or greater than the attributable risk to drinking water (6-22%) calculated for 14 Wisconsin community PWSs with much lower TC detection probabilities (about 2.3%, Borchardt et al., 2012). Published by Elsevier GmbH.
Tepe, Bektas; Sokmen, Atalay
2007-11-01
Methanolic extracts of three different Tanacetum subspecies [Tanacetum densum (Lab.) Schultz Bip. subsp. sivasicum Hub-Mor and Grierson, Tanacetum densum (Lab.) Schultz Bip. subsp. eginense Heywood and Tanacetum densum (Lab.) Schultz Bip. subsp. amani Heywood] which are endemic to Turkish flora were screened for their possible antioxidant activities by two complementary test systems namely DPPH free radical scavenging and beta-carotene/linoleic acid. In DPPH system, the most active plant was T. densum subsp. amani with an IC(50) value of 69.30+/-0.37 microg/ml. On the other hand, T. densum subsp. sivasicum exerted greater antioxidant activity than those of other subspecies in beta-carotene/linoleic acid system (79.10%+/-1.83). Antioxidant activities of BHT, curcumine and ascorbic acid were also determined as positive controls in parallel experiments. Total phenolic constituents of the extracts of Tanacetum subspecies were performed employing the literature methods involving Folin-Ciocalteu reagent and gallic acid as standard. The amount of total phenolics was highest in subsp. sivasicum (162.33+/-3.57 microg/mg), followed by subsp. amani (158.44+/-2.17 microg/mg). Especially, a positive correlation was observed between total phenolic content and antioxidant activity of the extracts.
Schumacher, Loni L.; Huss, Anne R.; Cochrane, Roger A.; Stark, Charles R.; Woodworth, Jason C.; Bai, Jianfa; Poulsen, Elizabeth G.; Chen, Qi; Main, Rodger G.; Zhang, Jianqiang; Gauger, Phillip C.; Ramirez, Alejandro; Derscheid, Rachel J.; Magstadt, Drew M.; Dritz, Steve S.
2017-01-01
New regulatory and consumer demands highlight the importance of animal feed as a part of our national food safety system. Porcine epidemic diarrhea virus (PEDV) is the first viral pathogen confirmed to be widely transmissible in animal food. Because the potential for viral contamination in animal food is not well characterized, the objectives of this study were to 1) observe the magnitude of virus contamination in an animal food manufacturing facility, and 2) investigate a proposed method, feed sequencing, to decrease virus decontamination on animal food-contact surfaces. A U.S. virulent PEDV isolate was used to inoculate 50 kg swine feed, which was mixed, conveyed, and discharged into bags using pilot-scale feed manufacturing equipment. Surfaces were swabbed and analyzed for the presence of PEDV RNA by quantitative real-time polymerase chain reaction (qPCR). Environmental swabs indicated complete contamination of animal food-contact surfaces (0/40 vs. 48/48, positive baseline samples/total baseline samples, positive subsequent samples/total subsequent samples, respectively; P < 0.05) and near complete contamination of non-animal food-contact surfaces (0/24 vs. 16/18, positive baseline samples/total baseline samples, positive subsequent samples/total subsequent samples, respectively; P < 0.05). Flushing animal food-contact surfaces with low-risk feed is commonly used to reduce cross-contamination in animal feed manufacturing. Thus, four subsequent 50 kg batches of virus-free swine feed were manufactured using the same system to test its impact on decontaminating animal food-contact surfaces. Even after 4 subsequent sequences, animal food-contact surfaces retained viral RNA (28/33 positive samples/total samples), with conveying system being more contaminated than the mixer. A bioassay to test infectivity of dust from animal food-contact surfaces failed to produce infectivity. This study demonstrates the potential widespread viral contamination of surfaces in an animal food manufacturing facility and the difficulty of removing contamination using conventional feed sequencing, which underscores the importance for preventing viruses from entering and contaminating such facilities. PMID:29095859
Sanders, Gabriel J; Roll, Brad; Peacock, Corey A; Kollock, Roger O
2018-05-02
Sanders, GJ, Roll, B, Peacock, CA, and Kollock, RO. Maximum movement workloads and high-intensity workload demands by position in NCAA division I collegiate football. J Strength Cond Res XX(X): 000-000, 2018-The purpose of the study was to quantify the average and maximum (i.e., peak) movement workloads, and the percent of those workloads performed at high intensity by NCAA division I football athletes during competitive games. Using global positioning system devices (Catapult Sports), low, moderate, and high and total multidirectional movement workloads were quantified by each position. Strategically achieving maximal workloads may improve both conditioning and rehabilitation protocols for athletes as they prepare for competition or return to play after an injury. A total of 40 football athletes were included in the analysis. For the data to be included, athletes were required to participate in ≥75% of the offensive or defensive snaps for any given game. There was a total of 286 data downloads from 13 different games for 8 different football positions. Data were calculated and compared by offensive and defensive position to establish the mean, SD, and maximum workloads during competitive games. The percent high-intensity workload profile was established to assess the total number and percent of high-intensity movement workloads by position. The profile was calculated by dividing a position's maximal high-intensity movement workload by the total (e.g., sum of maximal low, moderate, and high-intensity movements) movement workload. One-way analysis of variances revealed that there was a main effect of football position for total movement workloads and the percent of workloads performed at high intensities (p ≤ 0.025 for all). Maximal high-intensity workloads were 1.6-4.3 times greater than average high-intensity workloads, and the percent of total workloads performed at high intensities varied greatly by position. Strategically training for and using maximal movement workloads can help ensure that athletes are achieving workloads that are similar to the greatest demands of a competitive game.
Gullo, Gregorio; Motisi, Antonio; Zappia, Rocco; Dattola, Agostino; Diamanti, Jacopo; Mezzetti, Bruno
2014-06-15
The right combination of rootstock and training system is important for increased yield and fruit sensorial and nutritional homogeneity and quality with peach [Prunus persica (L.) Batsch]. We investigated the effects of rootstock and training system on these parameters, testing the effect of vigorous GF677 and weaker Penta rootstock on 'Rich May' peach cultivar. Fruit position effects regarding photosynthetically active radiation availability, along the canopy profile using the Y training system, were investigated. The positive relationships between total polyphenols content and antioxidant capacity according to canopy vigour and architecture were determined for the two scion/stock combinations. Changes in fruit epicarp colour and content of bioactive compounds were also determined. Lower-vigour trees from Penta rootstock grafting yielded larger fruit with improved skin overcolour, and greater total polyphenols content and antioxidant capacity. GF677 rootstock produced more vigorous trees with fruit with lower sensorial and nutritional parameters. Canopy position strongly affects fruit sensorial and nutritional qualities. These data define potential for improvements to peach production efficiency and fruit quality, particularly for southern Europe peach cultivation conditions. Copyright © 2013 Elsevier Ltd. All rights reserved.
Variations of total electron content during geomagnetic disturbances: A model/observation comparison
NASA Technical Reports Server (NTRS)
Roble, G. Lu X. Pi A. D. Richmond R. G.
1997-01-01
This paper studies the ionospheric response to major geomagnetic storm of October 18-19, 1995, using the thermosphere-ionosphere electrodynamic general circulation model (TIE-GCM) simulations and the global ionospheric maps (GIM) of total electron content (TEC) observations from the Global Positioning System (GPS) worldwide network.
[An Exploration of Working Conditions and Flexible System for Hospital Nurses].
Huang, Chung-I; Yu, Chien; Yu, Chin-Cheh
2016-04-01
The lack of sufficient numbers of professional nurses in the healthcare system in Taiwan is an issue that affects the sustainability of this system and that relates closely to working conditions. The present study explores the expectations that nurses hold with regard to working conditions and the operation of a flexible system in hospitals. A literature review and focus-group interviews were used to develop the questionnaire Working Conditions and Flexible System. A total of 1,150 copies of this questionnaire were distributed to practicing nurses using stratified random sampling, with 1,146 valid copies returned for a valid recovery rate of 99.65%. The results show that the expectations of participants concerning working conditions and a flexible system focus on the 6 factors of task, numerical, divisional, temporal, wages, and leading flexibility. The total mean was 4.35 (SD=0.42). The means for the 6 types of flexibility were all greater than 4.0. Participants deemed flexibility to be of high importance. The demographic variables hospital, work location, age, education level, work position, work unit, and total work years all affected the 6 types of flexibility significantly. The present study supports that the retention of nurses is significantly associated with working conditions and the operation of a flexible system. Administrators and mangers must create positive working conditions and a flexible system in order to enhance the retention and career development of nurses.
Kempton, Thomas; Sullivan, Courtney; Bilsborough, Johann C; Cordy, Justin; Coutts, Aaron J
2015-01-01
To determine the match-to-match variability in physical activity and technical performance measures in Australian Football, and examine the influence of playing position, time of season, and different seasons on these measures of variability. Longitudinal observational study. Global positioning system, accelerometer and technical performance measures (total kicks, handballs, possessions and Champion Data rank) were collected from 33 players competing in the Australian Football League over 31 matches during 2011-2012 (N=511 observations). The global positioning system data were categorised into total distance, mean speed (mmin(-1)), high-speed running (>14.4 kmh(-1)), very high-speed running (>19.9 kmh(-1)), and sprint (>23.0 kmh(-1)) distance while player load was collected from the accelerometer. The data were log transformed to provide coefficient of variation and the between subject standard deviation (expressed as percentages). Match-to-match variability was increased for higher speed activities (high-speed running, very high-speed running, sprint distance, coefficient of variation %: 13.3-28.6%) compared to global measures (speed, total distance, player load, coefficient of variation %: 5.3-9.2%). The between-match variability was relativity stable for all measures between and within AFL seasons, with only few differences between positions. Higher speed activities (high-speed running, very high-speed running, sprint distance), but excluding mean speed, total distance and player load, were all higher in the final third phase of the season compared to the start of the season. While global measures of physical performance are relatively stable, higher-speed activities and technical measures exhibit a large degree of between-match variability in Australian Football. However, these measures remain relatively stable between positions, and within and between Australian Football League seasons. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Jansen, Ruben; Bathgate, Brigitte; Bufe, Alexander
2018-01-01
Percutaneous coronary intervention (PCI) of chronic total occlusion (CTO) still remains a major challenge in interventional cardiology. This case describes a complex PCI of the left main coronary artery and of a CTO of the right coronary artery using a minimal extracorporeal circulation system (MECC) in a patient with an aortic valve bioprothesis in extraanatomic position. It illustrates that complex recanalization strategies can be solved combining it with mechanical circulatory support technologies. PMID:29850264
Duda, Scott; Kandiah, Sheena; Stout, Janet E; Baron, Julianne L; Yassin, Mohamed; Fabrizio, Marie; Ferrelli, Juliet; Hariri, Rahman; Wagener, Marilyn M; Goepfert, John; Bond, James; Hannigan, Joseph; Rogers, Denzil
2014-11-01
To evaluate the efficacy of a new monochloramine generation system for control of Legionella in a hospital hot water distribution system. A 495-bed tertiary care hospital in Pittsburgh, Pennsylvania. The hospital has 12 floors covering approximately 78,000 m(2). The hospital hot water system was monitored for a total of 29 months, including a 5-month baseline sampling period prior to installation of the monochloramine system and 24 months of surveillance after system installation (postdisinfection period). Water samples were collected for microbiological analysis (Legionella species, Pseudomonas aeruginosa, Stenotrophomonas maltophilia, Acinetobacter species, nitrifying bacteria, heterotrophic plate count [HPC] bacteria, and nontuberculous mycobacteria). Chemical parameters monitored during the investigation included monochloramine, chlorine (free and total), nitrate, nitrite, total ammonia, copper, silver, lead, and pH. A significant reduction in Legionella distal site positivity was observed between the pre- and postdisinfection periods, with positivity decreasing from an average of 53% (baseline) to an average of 9% after monochloramine application (P<0.5]). Although geometric mean HPC concentrations decreased by approximately 2 log colony-forming units per milliliter during monochloramine treatment, we did not observe significant changes in other microbial populations. This is the first evaluation in the United States of a commercially available monochloramine system installed on a hospital hot water system for Legionella disinfection, and it demonstrated a significant reduction in Legionella colonization. Significant increases in microbial populations or other negative effects previously associated with monochloramine use in large municipal cold water systems were not observed.
Comparisons of Physicians' and Nurses' Attitudes towards Computers.
Brumini, Gordana; Ković, Ivor; Zombori, Dejvid; Lulić, Ileana; Bilic-Zulle, Lidija; Petrovecki, Mladen
2005-01-01
Before starting the implementation of integrated hospital information systems, the physicians' and nurses' attitudes towards computers were measured by means of a questionnaire. The study was conducted in Dubrava University Hospital, Zagreb in Croatia. Out of 194 respondents, 141 were nurses and 53 physicians, randomly selected. They surveyed by an anonymous questionnaire consisting of 8 closed questions about demographic data, computer science education and computer usage, and 30 statements on attitudes towards computers. The statements were adapted to a Likert type scale. Differences in attitudes towards computers between groups were compared using Kruskal-Wallis and Mann Whitney test for post-hoc analysis. The total score presented attitudes toward computers. Physicians' total score was 130 (97-144), while nurses' total score was 123 (88-141). It points that the average answer to all statements was between "agree" and "strongly agree", and these high total scores indicated their positive attitudes. Age, computer science education and computer usage were important factors witch enhances the total score. Younger physicians and nurses with computer science education and with previous computer experience had more positive attitudes towards computers than others. Our results are important for planning and implementation of integrated hospital information systems in Croatia.
Does patella position influence ligament balancing in total knee arthroplasty?
Yoon, Jung-Ro; Oh, Kwang-Jun; Wang, Joon Ho; Yang, Jae-Hyuk
2015-07-01
In vivo comparative gap measurements were performed in three different patella positions (reduced, subluxated and everted) using offset-type-force-controlled-spreader-system. Prospectively, 50 knees were operated by total knee arthroplasty using a navigation-assisted gap-balancing technique. The offset-type-force-controlled-spreader-system was used for gap measurements. This commercially available instrument allows controllable tension in patella-reduced position. The mediolateral gaps of knee extension (0°) and flexion (90°) angle were recorded in three different patella positions; reduced, subluxated and everted. Any gap differences of more than 3 mm were considered as a meaningful difference. Correlation between the difference with the demographic data, preoperative radiologic alignment and intraoperative data was analysed. For statistical analysis, ANOVA and Pearson's correlation test were used. The gaps in patella eversion demonstrated smaller gaps both in knee extension and flexion position compared to the gaps of patella reduction position. The amount of decreased gaps was more definite in knee flexion position. Statistically significant difference was observed for the lateral gap of patella eversion compared to gap of patella reduction in knee flexion position (p < 0.05). There were notable cases of variability in knee flexion position. Significant portion of 12 (24 %) knees of patella subluxation and 33 (66 %) knees of patella evertion demonstrated either increased or decreased gaps in knee flexion position compared to the gaps of patella reduction position. The gaps in patella eversion demonstrated smaller gaps both in knee extension and flexion position compared to the gaps of patella reduction position. The amount of decreased gaps was more definite in knee flexion position. Therefore, the intraoperative patellar positioning has influence on the measurement of the joint gap. Keeping the patella in reduced position is important during gap balancing. I.
Nishino, K; Hayashi, T; Suzuki, Y; Koga, Y; Omori, G
1999-01-01
The function and integrity of the knee joint following total knee arthroplasty (TKA) is determined at first by the design and implantation of the prosthesis, and later by the tension of soft tissues surrounding it. Accurate post-TKA motion data obtained intraoperatively could be used not only to optimize implantation techniques from a kinematic standpoint, but also to improve prosthetic design. We therefore developed a system specifically geared to photostereometric measurement of 6 d.o.f. knee motion. A total of eight LEDs are mounted on the prosthetic components in two sets of four by means of connecting measuring-bows. The positions of the LEDs are detected in three-dimensions by two sets of three linear CCD cameras, located bilaterally relative to the knee. The position and orientation of the femoral component relative to the tibial one are estimated from the positions of all LEDs in the sense of least-squares. Based upon results of various accuracy validation experiments performed after precise camera calibration, static overall accuracy and spatial resolution were considered to lie within 0.52 and 0.11 mm, respectively, at any point on the femoral articular surface.
System Finds Horizontal Location of Center of Gravity
NASA Technical Reports Server (NTRS)
Johnston, Albert S.; Howard, Richard T.; Brewster, Linda L.
2006-01-01
An instrumentation system rapidly and repeatedly determines the horizontal location of the center of gravity of a laboratory vehicle that slides horizontally on three air bearings (see Figure 1). Typically, knowledge of the horizontal center-of-mass location of such a vehicle is needed in order to balance the vehicle properly for an experiment and/or to assess the dynamic behavior of the vehicle. The system includes a load cell above each air bearing, electronic circuits that generate digital readings of the weight on each load cell, and a computer equipped with software that processes the readings. The total weight and, hence, the mass of the vehicle are computed from the sum of the load-cell weight readings. Then the horizontal position of the center of gravity is calculated straightforwardly as the weighted sum of the known position vectors of the air bearings, the contribution of each bearing being proportional to the weight on that bearing. In the initial application for which this system was devised, the center- of-mass calculation is particularly simple because the air bearings are located at corners of an equilateral triangle. However, the system is not restricted to this simple geometry. The system acquires and processes weight readings at a rate of 800 Hz for each load cell. The total weight and the horizontal location of the center of gravity are updated at a rate of 800/3 approx. equals 267 Hz. In a typical application, a technician would use the center-of-mass output of this instrumentation system as a guide to the manual placement of small weights on the vehicle to shift the center of gravity to a desired horizontal position. Usually, the desired horizontal position is that of the geometric center. Alternatively, this instrumentation system could be used to provide position feedback for a control system that would cause weights to be shifted automatically (see Figure 2) in an effort to keep the center of gravity at the geometric center.
Surase, P V; Nataraj, G; Pattamadai, K; Mehta, P R; Pazare, A R; Agarwal, M C; Nanavati, R N
2016-01-01
Comparison of conventional blood culture with BACTEC 9050 for rate and time to detection of microorganisms. A prospective study was carried out in a multispecialty tertiary care teaching hospital. A total of 835 paired specimens (797 blood and 38 nonblood specimens) were collected and processed according to standard microbiological procedures by both conventional method as well as by BACTEC 9050 automated culture system. Clinical details of patients were recorded. Data were analyzed for time to detection and isolation rate by the two systems and compared. Overall culture positivity for BACTEC 9050 and the conventional system was 32% and 19.88%, respectively. Eighty-five demonstrated concordant growth, 136 specimens were culture positive by BACTEC only, and 38 specimens were culture positive by conventional only. Twelve contaminants in BACTEC and nine contaminants in conventional system were detected. Using BACTEC 9050, higher isolation was observed for Acinetobacter spp., coagulase negative Staphylococcus spp., Streptococcus spp., and Candida spp. A total of 410 patients were on antimicrobial treatment and culture positivity was significantly higher with BACTEC 9050 (P < 0.0001). There was a significant difference in the mean time to detection with BACTEC 9050 recovering 86.8% of isolates within 48 h (P < 0.0001). Although BACTEC 9050 demonstrated a significantly higher recovery of microorganisms from blood, an appropriately performed conventional blood culture can facilitate the choice of therapy.
49 CFR 236.1005 - Requirements for Positive Train Control systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... be equipped with a PTC system shall be determined and reported as follows: (i) The traffic density... installed, based upon changes in rail traffic such as reductions in total traffic volume or cessation of... review of the requirement to install PTC on a low density track segment where a PTC system is otherwise...
Ionospheric TEC Weather Map Over South America
NASA Astrophysics Data System (ADS)
Takahashi, H.; Wrasse, C. M.; Denardini, C. M.; Pádua, M. B.; de Paula, E. R.; Costa, S. M. A.; Otsuka, Y.; Shiokawa, K.; Monico, J. F. Galera; Ivo, A.; Sant'Anna, N.
2016-11-01
Ionospheric weather maps using the total electron content (TEC) monitored by ground-based Global Navigation Satellite Systems (GNSS) receivers over South American continent, TECMAP, have been operationally produced by Instituto Nacional de Pesquisas Espaciais's Space Weather Study and Monitoring Program (Estudo e Monitoramento Brasileiro de Clima Especial) since 2013. In order to cover the whole continent, four GNSS receiver networks, (Rede Brasileiro de Monitoramento Contínuo) RBMC/Brazilian Institute for Geography and Statistics, Low-latitude Ionospheric Sensor Network, International GNSS Service, and Red Argentina de Monitoreo Satelital Continuo, in total 140 sites, have been used. TECMAPs with a time resolution of 10 min are produced in 12 h time delay. Spatial resolution of the map is rather low, varying between 50 and 500 km depending on the density of the observation points. Large day-to-day variabilities of the equatorial ionization anomaly have been observed. Spatial gradient of TEC from the anomaly trough (total electron content unit, 1 TECU = 1016 el m-2 (TECU) <10) to the crest region (TECU > 80) causes a large ionospheric range delay in the GNSS positioning system. Ionospheric plasma bubbles, their seeding and development, could be monitored. This plasma density (spatial and temporal) variability causes not only the GNSS-based positioning error but also radio wave scintillations. Monitoring of these phenomena by TEC mapping becomes an important issue for space weather concern for high-technology positioning system and telecommunication.
Hsiao, Ju-Ling; Chen, Rai-Fu
2012-05-01
This study investigates factors affecting the fit between nursing tasks and mobile nursing information systems and the relationships between the task-technology fit of mobile nursing information systems and nurse performance from the perspective of task-technology fit. Survey research recruited nursing staffs as subjects from selected case hospital. A total of 310 questionnaires were sent out, and 219 copies were obtained, indicating a valid response rate of 70.6%. Collected data were analyzed using the structural equation modeling technique. Our study found that dependence tasks have positive effects on information acquisition (γ=0.234, P<.05) and information identification (γ=0.478, P<.001), and independent tasks have significant effects on information acquisition (γ=0.213, P<.05). Therefore, the introduction of mobile nursing information systems in assisting nursing practices can help facilitate both independent and dependent nursing tasks. Our study discovered that the supporting functions of mobile nursing information systems have positive effects on information integration and interpretation (γ=0.365, P<.001), as well as information acquisition (γ=0.253, P<.05). The service supports of mobile nursing information systems have positive effects on information acquisition (γ=0.318, P<.001) and information integration and interpretation (γ=0.143, P<.01). Furthermore, information identification (β=.055, P<.05), information acquisition (β=.176, P<.001), and information integration and interpretation (β=.706, P<.001) provided using mobile nursing information systems have positive effects on nursing performance, indicating 83.2% of totally explained variance. As shown, the use of mobile nursing information systems could provide nursing staffs with real-time and accurate information to increase efficiency and effectiveness in patient-care duties, further improving nursing performance.
The automation of an inlet mass flow control system
NASA Technical Reports Server (NTRS)
Supplee, Frank; Tcheng, Ping; Weisenborn, Michael
1989-01-01
The automation of a closed-loop computer controlled system for the inlet mass flow system (IMFS) developed for a wind tunnel facility at Langley Research Center is presented. This new PC based control system is intended to replace the manual control system presently in use in order to fully automate the plug positioning of the IMFS during wind tunnel testing. Provision is also made for communication between the PC and a host-computer in order to allow total animation of the plug positioning and data acquisition during the complete sequence of predetermined plug locations. As extensive running time is programmed for the IMFS, this new automated system will save both manpower and tunnel running time.
The metabolic power and energetic demands of elite Gaelic football match play.
Malone, Shane; Solan, Barry; Collins, Kieran; Doran, Dominic
2017-05-01
Metabolic power has not yet been investigated within elite Gaelic football. The aim of the current investigation was to compare the metabolic power demands between positional groups and examine the temporal profile of elite Gaelic football match play. Global positional satellite system (GPS) data were collected from 50 elite Gaelic football players from 4 inter-county teams during 35 elite competitive matches over a three season period. A total of 351 complete match samples were obtained for final analysis. Players were categorized based on positional groups; full-back, half-back, midfield, half-forward and full-forward. Instantaneous raw velocity data was obtained from the GPS and exported to a customized spreadsheet which provided estimations of both speed based, derived metabolic power and energy expenditure variables (total distance, high speed distance, average metabolic power, high power distance and total energy expenditure). Match mean distance was 9222±1588 m, reflective of an average metabolic power of 9.5-12.5 W·kg-1, with an average energy expenditure of 58-70 Kj·kg-1 depending on position. There were significant differences between positional groups for both speed-based and metabolic power indices. Midfielders covered more total and high-speed distance, as well as greater average and overall energy expenditure compared to other positions (P<0.001). A reduction in total, high-speed, and high-power distance, as well as average metabolic power throughout the match (P<0.001) was observed. Positional differences exist for both metabolic power and traditional running based variables. The middle three positions (midfield, half-back and half-forward) possess greater activity profiles when compared to other positional groups. The reduction in metabolic power and traditional running based variables are comparable across match play. The current study demonstrates that metabolic power may contribute to our understanding of Gaelic football match-play.
Status of microbial diversity in agroforestry systems in Tamil Nadu, India.
Radhakrishnan, Srinivasan; Varadharajan, Mohan
2016-06-01
Soil is a complex and dynamic biological system. Agroforestry systems are considered to be an alternative land use option to help and prevent soil degradation, improve soil fertility, microbial diversity, and organic matter status. An increasing interest has emerged with respect to the importance of microbial diversity in soil habitats. The present study deals with the status of microbial diversity in agroforestry systems in Tamil Nadu. Eight soil samples were collected from different fields in agroforestry systems in Cuddalore, Villupuram, Tiruvanamalai, and Erode districts, Tamil Nadu. The number of microorganisms and physico-chemical parameters of soils were quantified. Among different microbial population, the bacterial population was recorded maximum (64%), followed by actinomycetes (23%) and fungi (13%) in different samples screened. It is interesting to note that the microbial population was positively correlated with the physico-chemical properties of different soil samples screened. Total bacterial count had positive correlation with soil organic carbon (C), moisture content, pH, nitrogen (N), and micronutrients such as Iron (Fe), copper (Cu), and zinc (Zn). Similarly, the total actinomycete count also showed positive correlations with bulk density, moisture content, pH, C, N, phosphorus (P), potassium (K), calcium (Ca), copper (Cu), magnesium (Mg), manganese (Mn), and zinc (Zn). It was also noticed that the soil organic matter, vegetation, and soil nutrients altered the microbial community under agroforestry systems. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
New beam-position monitor system for upgraded Photon Factory storage ring.
Haga, K; Honda, T; Tadano, M; Obina, T; Kasuga, T
1998-05-01
Accompanying the brilliance-upgrading project at the Photon Factory storage ring, the beam-position monitor (BPM) system has been renovated. The new system was designed to enable precise and fast measurements to correct the closed-orbit distortion (COD), as well as to feed back the orbit position during user runs. There are 42 BPMs newly installed, amounting to a total of 65 BPMs. All of the BPMs are calibrated on the test bench using a coaxially strung metallic wire. The measured electrical offsets are typically 200 micro m in both directions, which is 1/2-1/3 of those of the old-type BPMs. In the signal-processing system, PIN diode switches are employed in order to improve reliability. In the fastest mode, this system is capable of measuring COD within about 10 ms; this fast acquisition will allow fast suppression of the beam movement for frequencies up to 50 Hz using a global feedback system.
Positive emotion inducement modulates cardiovascular responses caused by mental work.
Liu, Xinxin; Ishimatsu, Kazuma; Sotoyama, Midori; Iwakiri, Kazuyuki
2016-11-16
Positive emotion is considered as an important factor related to health-relevant biological processes, including cardiovascular responses. To explore the possibility of using positive emotion as a tool to manage cardiovascular response of white-collar workers, we examined the influence on cardiovascular response of positive emotion inducement before a mental work. Seventeen healthy males participated and performed a 10-min, PC-based Stroop color word task as their mental work. Before the task, 60 pleasant pictures chosen from the International Affective Picture System were presented in a random order under a positive emotion inducement condition while a gray screen was presented under a control condition. A 30-min relaxation period after completing the task was provided to examine the aftereffects of positive emotion inducement. Throughout these periods, systolic and diastolic blood pressure, mean arterial blood pressure, heart rate, stroke volume, cardiac output, and total peripheral resistance were measured continuously. Blood pressure and total peripheral resistance were lower during the picture presentation period under the positive emotion inducement period compared to the control condition. All indices did not differ during the color word task period. During the relaxation period after the task, however, blood pressure and total peripheral resistance were lower under the positive emotion inducement condition compared to the control condition. Positive emotion inducement before a mental work beneficially modulates cardiovascular responses, suggesting that positive emotion inducement may be a useful tool to manage the cardiovascular response to mental work.
Deployment Mechanism for Thermal Pointing System
NASA Technical Reports Server (NTRS)
Koski, Kraig
2014-01-01
The Deployment Mechanism for the Total and Spectral Solar Irradiance Sensor (TSIS) is responsible for bringing the Thermal Pointing System (TPS) from its stowed, launch locked position to the on-orbit deployed, operational position. The Deployment Mechanism also provides structural support for the TSIS optical bench and two-axis gimbal. An engineering model of the Deployment Mechanism has been environmentally qualified and life tested. This paper will give an overview of the TSIS mission and then describe the development, design, and testing of the Deployment Mechanism.
Rapid automated method for screening of enteric pathogens from stool specimens.
Villasante, P A; Agulla, A; Merino, F J; Pérez, T; Ladrón de Guevara, C; Velasco, A C
1987-01-01
A total of 800 colonies suggestive of Salmonella, Shigella, or Yersinia species isolated on stool differential agar media were inoculated onto both conventional biochemical test media (triple sugar iron agar, urea agar, and phenylalanine agar) and Entero Pathogen Screen cards of the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). Based on the conventional tests, the AutoMicrobic system method yielded the following results: 587 true-negatives, 185 true-positives, 2 false-negatives, and 26 false-positives (sensitivity, 99%; specificity, 96%). Both true-positive and true-negative results were achieved considerably earlier than false results (P less than 0.001). The Entero Pathogen Screen card method is a fast, easy, and sensitive method for screening for Salmonella, Shigella, or Yersinia species. The impossibility of screening for oxidase-positive pathogens is a minor disadvantage of this method. PMID:3553230
Method and apparatus for hybrid position/force control of multi-arm cooperating robots
NASA Technical Reports Server (NTRS)
Hayati, Samad A. (Inventor)
1989-01-01
Two or more robotic arms having end effectors rigidly attached to an object to be moved are disclosed. A hybrid position/force control system is provided for driving each of the robotic arms. The object to be moved is represented as having a total mass that consists of the actual mass of the object to be moved plus the mass of the moveable arms that are rigidly attached to the moveable object. The arms are driven in a positive way by the hybrid control system to assure that each arm shares in the position/force applied to the object. The burden of actuation is shared by each arm in a non-conflicting way as the arm independently control the position of, and force upon, a designated point on the object.
40 CFR 142.14 - Records kept by States.
Code of Federal Regulations, 2011 CFR
2011-07-01
...)—Any decision to allow a public water system to forgo fecal coliform or E. coli testing on a total...-positive or E. coli- positive, as provided in § 141.21(e)(2). (6) Records of analysis for other than... part 141, subpart W of this chapter. (i) Results of source water E. coli and Cryptosporidium monitoring...
Crisis in Red and White - An Educational Dilemma. Position Paper.
ERIC Educational Resources Information Center
Sawyer, Thomas E.
The goal of this position paper is to present considerations and alternatives for healthy life directions which can be made available through education to the Native American to enable him to go beyond the present narrow choices of either total assimilation within the white value system or remaining isolated on the reservation. The 3 purposes of…
Wellman, Aaron D; Coad, Sam C; Goulet, Grant C; McLellan, Christopher P
2016-01-01
The aim of the present study was to examine the competitive physiological movement demands of National Collegiate Athletic Association (NCAA) Division I college football players using portable global positioning system (GPS) technology during games and to examine positional groups within offensive and defensive teams, to determine if a player's physiological requirements during games are influenced by playing position. Thirty-three NCAA Division I Football Bowl Subdivision football players were monitored using GPS receivers with integrated accelerometers (GPSports) during 12 regular season games throughout the 2014 season. Individual data sets (n = 295) from players were divided into offensive and defensive teams and subsequent position groups. Movement profile characteristics, including total, low-intensity, moderate-intensity, high-intensity, and sprint running distances (m), sprint counts, and acceleration and deceleration efforts, were assessed during games. A one-way ANOVA and post-hoc Bonferroni statistical analysis were used to determine differences in movement profiles between each position group within offensive and defensive teams. For both offensive and defensive teams, significant (p ≤ 0.05) differences exist between positional groups for game physical performance requirements. The results of the present study identified that wide receivers and defensive backs completed significantly (p ≤ 0.05) greater total distance, high-intensity running, sprint distance, and high-intensity acceleration and deceleration efforts than their respective offensive and defensive positional groups. Data from the present study provide novel quantification of position-specific physical demands of college football games and support the use of position-specific training in the preparation of NCAA Division I college football players for competition.
[Optimizing primary total hip replacement--a technique to effect saving of manpower].
Huber, J F; Rink, M; Broger, I; Zumstein, M; Ruflin, G B
2003-01-01
Development of a standardized surgical technique for total hip replacement thereby saving manpower (one assistant) by using a retractor system. Total hip replacement is performed with the patient in a true lateral position on a tunnel cushion. By means of a direct lateral approach the pelvitrochanteric muscles are partially detached using an omega-shaped cut. The Bookwalter retractor is fixed dorsally on the operating table. The ring is centered keeping the greater trochanter in the middle. The Hohmann retractors are fixed to the ring to sufficiently expose the acetabulum. To insert the femoral stem the ring needs to be opened dorsally and the patient's leg is bent 90 degrees in the hip and the knee over the tunnel cushion. The muscles inserting at the greater trochanter are retracted by a separate Hohmann retractor with weight. In a case control study with matched pairs the patients treated with this technique were compared with those treated in supine position with the transgluteal approach. The number of assistants required and the operating time were assessed. All the hip replacements with the patient in side position were performed with one assistant, in supine position with two assistants. The operating time did not differ significantly (supine position 110 min/side position 112 min). The complication rate in both groups was comparable (one secondary wound healing, one transient ischalgia). The process of total hip replacement can be optimized. The described technique allows to spare one surgical assistant without prolonging the operating time.
Miller, Eric; Cantrell, Christopher; Beard, Melodie; Derylak, Andrew; Babady, N Esther; McMillen, Tracy; Miranda, Edwin; Body, Barbara; Tang, Yi-Wei; Vasireddy, Ravikiran; Vasireddy, Sruthi; Smith, Terry; Iakhiaeva, Elena; Wallace, Richard J; Brown-Elliott, Barbara A; Moreno, Erik; Totty, Heather; Deol, Parampal
2018-06-06
The accuracy and robustness of the VITEK® MS V3.0 matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) system was evaluated by identifying mycobacteria from automated liquid media systems using patient samples. This is the first report demonstrating that proteins within the liquid media, its supplements, and decontamination reagents for non-sterile patient samples do not generate misidentification or false positive results when using the VITEK MS V3.0 system. Prior to testing with patient samples, a seeded study was conducted to challenge the accuracy of the VITEK MS to identify mycobacteria from liquid media through mimicking a clinical workflow. A total of 77 Mycobacterium strains representing 21 species, seeded in simulated sputum, were decontaminated and inoculated into BACT/ALERT®MP liquid culture medium, incubated until positivity, and identified using VITEK MS. A total of 383 liquid cultures were tested of which 379 (99%) identified correctly to the species/complex/group; four (1%) obtained a No Identification, and no misidentifications were observed. Following the simulated sputum study, a total of 73 smear-positive liquid medium cultures detected using BD BBL™ MGIT™ and VersaTREK® MYCO liquid media were identified by VITEK MS. Sixty-four (87.7%) correctly identified to the species/complex/group level; seven (9.6%) resulted as No Identification, and two (2.7%) misidentified at the species level. These results indicate the VITEK MS V3.0 is an accurate tool for routine diagnostics of Mycobacterium species isolated from liquid cultures. Copyright © 2018 American Society for Microbiology.
Nature of non-nuclear (3, -3) π-attractor and π-bonding: Theoretical analysis on π-electron density
NASA Astrophysics Data System (ADS)
Lv, Jiao; Yang, Lihua; Sun, Zheng; Meng, Lingpeng; Li, Xiaoyan
2018-01-01
Understanding the nature of π-electron density is important to characterize the conjugate π molecular systems. In this work, the π-electron densities of some typical conjugated π molecular systems were separated from their total electron densities; the positions and natures of non-nuclear (3, -3) π-attractors and the π-bond critical points (π-BCPs) are investigated. The calculated results show that for the same element, the position of the π-attractor is constant, regardless of the chemical surroundings. The position of the π-BCP is closer to the atom with the larger electronegativity.
Shelbourne, K Donald; Barnes, Adam F; Gray, Tinker
2012-11-01
Limited studies exist regarding how well a single assessment numeric evaluation (SANE) rating correlates with validated knee surveys. To determine whether a SANE rating correlates positively with the International Knee Documentation Committee (IKDC) and the modified Cincinnati Knee Rating System (CKRS) total scores after knee surgery. Cohort study (Diagnosis); Level of evidence, 2. Patients undergoing either anterior cruciate ligament (ACL) reconstruction or knee arthroscopy were prospectively given subjective evaluations yearly after surgery between January 2000 and June 2011. Subjective evaluations were obtained using modified CKRS and IKDC subjective knee surveys and a SANE rating. Interclass correlation coefficient was used to determine the correlation of the SANE rating to the survey total scores. Bland-Altman method was used to access precision and limits of agreement between scores. In addition, the data were analyzed according to sex and age categories (<18, 18-24, 25-40, >40 years). A total of 11,939 surveys were collected from 3209 patients (mean, 3.7 surveys/person; range, 1-22) after ACL reconstruction with a mean survey age of 35.2 ± 11.9 years (range, 13-72). A total of 4615 surveys were collected from 1813 patients (mean, 2.6 surveys/person; range, 1-17) after knee arthroscopy with a mean survey age of 47.4 ± 14.6 years (range, 11-88). For patients who underwent ACL reconstruction, the SANE rating had a moderate positive correlation of 0.66 to the total survey scores. For patients who underwent knee arthroscopies, the SANE rating had a strong positive correlation of 0.74 to total scores. There was minimal difference in correlations based on age group or sex. Bland-Altman analysis showed that the limits of agreement between the SANE score and the 2 surveys were met for at least 94% of patients in both patient groups. The SANE ratings exhibited moderate to strong positive correlations with the modified CKRS and IKDC subjective surveys after ACL reconstruction and knee arthroscopy for patients of all ages and both sexes.
An Inertial and Optical Sensor Fusion Approach for Six Degree-of-Freedom Pose Estimation
He, Changyu; Kazanzides, Peter; Sen, Hasan Tutkun; Kim, Sungmin; Liu, Yue
2015-01-01
Optical tracking provides relatively high accuracy over a large workspace but requires line-of-sight between the camera and the markers, which may be difficult to maintain in actual applications. In contrast, inertial sensing does not require line-of-sight but is subject to drift, which may cause large cumulative errors, especially during the measurement of position. To handle cases where some or all of the markers are occluded, this paper proposes an inertial and optical sensor fusion approach in which the bias of the inertial sensors is estimated when the optical tracker provides full six degree-of-freedom (6-DOF) pose information. As long as the position of at least one marker can be tracked by the optical system, the 3-DOF position can be combined with the orientation estimated from the inertial measurements to recover the full 6-DOF pose information. When all the markers are occluded, the position tracking relies on the inertial sensors that are bias-corrected by the optical tracking system. Experiments are performed with an augmented reality head-mounted display (ARHMD) that integrates an optical tracking system (OTS) and inertial measurement unit (IMU). Experimental results show that under partial occlusion conditions, the root mean square errors (RMSE) of orientation and position are 0.04° and 0.134 mm, and under total occlusion conditions for 1 s, the orientation and position RMSE are 0.022° and 0.22 mm, respectively. Thus, the proposed sensor fusion approach can provide reliable 6-DOF pose under long-term partial occlusion and short-term total occlusion conditions. PMID:26184191
An Inertial and Optical Sensor Fusion Approach for Six Degree-of-Freedom Pose Estimation.
He, Changyu; Kazanzides, Peter; Sen, Hasan Tutkun; Kim, Sungmin; Liu, Yue
2015-07-08
Optical tracking provides relatively high accuracy over a large workspace but requires line-of-sight between the camera and the markers, which may be difficult to maintain in actual applications. In contrast, inertial sensing does not require line-of-sight but is subject to drift, which may cause large cumulative errors, especially during the measurement of position. To handle cases where some or all of the markers are occluded, this paper proposes an inertial and optical sensor fusion approach in which the bias of the inertial sensors is estimated when the optical tracker provides full six degree-of-freedom (6-DOF) pose information. As long as the position of at least one marker can be tracked by the optical system, the 3-DOF position can be combined with the orientation estimated from the inertial measurements to recover the full 6-DOF pose information. When all the markers are occluded, the position tracking relies on the inertial sensors that are bias-corrected by the optical tracking system. Experiments are performed with an augmented reality head-mounted display (ARHMD) that integrates an optical tracking system (OTS) and inertial measurement unit (IMU). Experimental results show that under partial occlusion conditions, the root mean square errors (RMSE) of orientation and position are 0.04° and 0.134 mm, and under total occlusion conditions for 1 s, the orientation and position RMSE are 0.022° and 0.22 mm, respectively. Thus, the proposed sensor fusion approach can provide reliable 6-DOF pose under long-term partial occlusion and short-term total occlusion conditions.
An Integrated Field-Based Approach to Building Teachers' Geoscience Skills
ERIC Educational Resources Information Center
Almquist, Heather; Stanley, George; Blank, Lisa; Hendrix, Marc; Rosenblatt, Megan; Hanfling, Seymour; Crews, Jeffrey
2011-01-01
The Paleo Exploration Project was a professional development program for K-12 teachers from rural eastern Montana. The curriculum was designed to incorporate geospatial technologies, including Global Positioning Systems (GPS), Geographic Information Systems (GIS), and total station laser surveying, with authentic field experiences in geology and…
Li, Chunjian; Tang, Lijun; Yang, Zhijian; Cao, Kejiang
2011-12-01
To investigate the feasibility of integration of the dual source computed tomography (DSCT) and magnetic navigation system (MNS) to guide percutaneous coronary intervention (PCI). MNS has proven to be feasible for yielding high rates of procedural success for PCI. DSCT coronary angiography (DSCT-CA) may provide a roadmap of a target vessel and serve as a reference route for MNS. Combination of these two technologies might decrease the contrast use, fluoroscopy exposure, and be beneficial to the intervention of the totally occluded lesions. Twenty-five patients with positive results of DSCT-CA and indications for PCI were included. CT images were transferred to MNS, and target vessels were extracted and registered to X-ray system as a roadmap. DSCT-CA and MNS-assisted PCIs were successfully performed in 25 of the 26 target vessels (96.2%), with the mean guidewire crossing time of 100.0 (25-75% inter-quartile ranges (IQR): 70.7-157.8) sec, mean total radiation dosage of 268.1 (IQR: 150.5-527.0) μGym(2) , or 42.0 (IQR: 23.0-70.0) mGy, respectively. The contrast usage for guidewire positioning was 0 (IQR: 0-3.0) ml for the successfully crossed lesions. Both of the two totally occluded lesions in this study were successfully crossed with guidewires under the guidance of the DSCT-CA derived roadmap. Integration of DSCT with MNS for PCI is feasible. This integration of advanced modalities might decrease contrast usage, lower fluoroscopy exposure for guidewire positioning, and might also play a role in totally occluded lesions. Copyright © 2011 Wiley Periodicals, Inc.
Cause-specific mortality according to urine albumin creatinine ratio in the general population.
Skaaby, Tea; Husemoen, Lise Lotte Nystrup; Ahluwalia, Tarunveer Singh; Rossing, Peter; Jørgensen, Torben; Thuesen, Betina Heinsbæk; Pisinger, Charlotta; Rasmussen, Knud; Linneberg, Allan
2014-01-01
Urine albumin creatinine ratio, UACR, is positively associated with all-cause mortality, cardiovascular disease and diabetes in observational studies. Whether a high UACR is also associated with other causes of death is unclear. We investigated the association between UACR and cause-specific mortality. We included a total of 9,125 individuals from two population-based studies, Monica10 and Inter99, conducted in 1993-94 and 1999-2001, respectively. Urine albumin creatinine ratio was measured from spot urine samples by standard methods. Information on causes of death was obtained from The Danish Register of Causes of Death until 31 December 2010. There were a total of 920 deaths, and the median follow-up was 11.3 years. Multivariable Cox regression analyses with age as underlying time axis showed statistically significant positive associations between UACR status and risk of all-cause mortality, endocrine nutritional and metabolic diseases, mental and behavioural disorders, diseases of the circulatory system, and diseases of the respiratory system with hazard ratios 1.56, 6.98, 2.34, 2.03, and 1.91, for the fourth UACR compared with the first, respectively. Using UACR as a continuous variable, we also found a statistically significant positive association with risk of death caused by diseases of the digestive system with a hazard ratio of 1.02 per 10 mg/g higher UACR. We found statistically significant positive associations between baseline UACR and death from all-cause mortality, endocrine nutritional and metabolic diseases, and diseases of the circulatory system and possibly mental and behavioural disorders, and diseases of the respiratory and digestive system.
van der List, Jelle P; Chawla, Harshvardhan; Joskowicz, Leo; Pearle, Andrew D
2016-11-01
Recently, there is a growing interest in surgical variables that are intraoperatively controlled by orthopaedic surgeons, including lower leg alignment, component positioning and soft tissues balancing. Since more tight control over these factors is associated with improved outcomes of unicompartmental knee arthroplasty and total knee arthroplasty (TKA), several computer navigation and robotic-assisted systems have been developed. Although mechanical axis accuracy and component positioning have been shown to improve with computer navigation, no superiority in functional outcomes has yet been shown. This could be explained by the fact that many differences exist between the number and type of surgical variables these systems control. Most systems control lower leg alignment and component positioning, while some in addition control soft tissue balancing. Finally, robotic-assisted systems have the additional advantage of improving surgical precision. A systematic search in PubMed, Embase and Cochrane Library resulted in 40 comparative studies and three registries on computer navigation reporting outcomes of 474,197 patients, and 21 basic science and clinical studies on robotic-assisted knee arthroplasty. Twenty-eight of these comparative computer navigation studies reported Knee Society Total scores in 3504 patients. Stratifying by type of surgical variables, no significant differences were noted in outcomes between surgery with computer-navigated TKA controlling for alignment and component positioning versus conventional TKA (p = 0.63). However, significantly better outcomes were noted following computer-navigated TKA that also controlled for soft tissue balancing versus conventional TKA (mean difference 4.84, 95 % Confidence Interval 1.61, 8.07, p = 0.003). A literature review of robotic systems showed that these systems can, similarly to computer navigation, reliably improve lower leg alignment, component positioning and soft tissues balancing. Furthermore, two studies comparing robotic-assisted with computer-navigated surgery reported superiority of robotic-assisted surgery in controlling these factors. Manually controlling all these surgical variables can be difficult for the orthopaedic surgeon. Findings in this study suggest that computer navigation or robotic assistance may help managing these multiple variables and could improve outcomes. Future studies assessing the role of soft tissue balancing in knee arthroplasty and long-term follow-up studies assessing the role of computer-navigated and robotic-assisted knee arthroplasty are needed.
Rhee, Seung Joon; Park, Shi Hwan; Cho, He Myung
2014-01-01
Purpose The purpose of this study is to compare and analyze the precision of optical and electromagnetic navigation systems in total knee arthroplasty (TKA). Materials and Methods We retrospectively reviewed 60 patients who underwent TKA using an optical navigation system and 60 patients who underwent TKA using an electromagnetic navigation system from June 2010 to March 2012. The mechanical axis that was measured on preoperative radiographs and by the intraoperative navigation systems were compared between the groups. The postoperative positions of the femoral and tibial components in the sagittal and coronal plane were assessed. Results The difference of the mechanical axis measured on the preoperative radiograph and by the intraoperative navigation systems was 0.6 degrees more varus in the electromagnetic navigation system group than in the optical navigation system group, but showed no statistically significant difference between the two groups (p>0.05). The positions of the femoral and tibial components in the sagittal and coronal planes on the postoperative radiographs also showed no statistically significant difference between the two groups (p>0.05). Conclusions In TKA, both optical and electromagnetic navigation systems showed high accuracy and reproducibility, and the measurements from the postoperative radiographs showed no significant difference between the two groups. PMID:25505703
Code of Federal Regulations, 2014 CFR
2014-07-01
... per month, the system has two or more total coliform-positive samples in the same month. (iii) The... second Level 1 trigger as defined in paragraph (a)(1) of this section, within a rolling 12-month period...) Level 1 treatment technique triggers. (i) For systems taking 40 or more samples per month, the system...
Code of Federal Regulations, 2013 CFR
2013-07-01
... per month, the system has two or more total coliform-positive samples in the same month. (iii) The... second Level 1 trigger as defined in paragraph (a)(1) of this section, within a rolling 12-month period...) Level 1 treatment technique triggers. (i) For systems taking 40 or more samples per month, the system...
Real-time implementation of camera positioning algorithm based on FPGA & SOPC
NASA Astrophysics Data System (ADS)
Yang, Mingcao; Qiu, Yuehong
2014-09-01
In recent years, with the development of positioning algorithm and FPGA, to achieve the camera positioning based on real-time implementation, rapidity, accuracy of FPGA has become a possibility by way of in-depth study of embedded hardware and dual camera positioning system, this thesis set up an infrared optical positioning system based on FPGA and SOPC system, which enables real-time positioning to mark points in space. Thesis completion include: (1) uses a CMOS sensor to extract the pixel of three objects with total feet, implemented through FPGA hardware driver, visible-light LED, used here as the target point of the instrument. (2) prior to extraction of the feature point coordinates, the image needs to be filtered to avoid affecting the physical properties of the system to bring the platform, where the median filtering. (3) Coordinate signs point to FPGA hardware circuit extraction, a new iterative threshold selection method for segmentation of images. Binary image is then segmented image tags, which calculates the coordinates of the feature points of the needle through the center of gravity method. (4) direct linear transformation (DLT) and extreme constraints method is applied to three-dimensional reconstruction of the plane array CMOS system space coordinates. using SOPC system on a chip here, taking advantage of dual-core computing systems, which let match and coordinate operations separately, thus increase processing speed.
Ha, Jihye; Han, Geum Hee; Kim, Myungsook; Lee, Kyungwon
2018-01-01
Background Early and appropriate antibiotic treatment improves the clinical outcome of patients with septicemia; therefore, reducing the turn-around time for identification (ID) and antimicrobial susceptibility test (AST) results is essential. We established a method for rapid ID and AST using short-term incubation of positive blood culture broth samples on solid media, and evaluated its performance relative to that of the conventional method using two rapid ID systems and a rapid AST method. Methods A total of 254 mono-microbial samples were included. Positive blood culture samples were incubated on blood agar plates for six hours and identified by the MicroFlex LT (Bruker Daltonics) and Vitek-MS (bioMeriéux) systems, followed by AST using the Vitek2 System (bioMeriéux). Results The correct species-level ID rates were 82.3% (209/254) and 78.3% (199/254) for the MicroFlex LT and Vitek-MS platforms, respectively. For the 1,174 microorganism/antimicrobial agent combinations tested, the rapid AST method showed total concordance of 97.8% (1,148/1,174) with the conventional method, with a very major error rate of 0.5%, major error rate of 0.7%, and minor error rate of 1.0%. Conclusions Routine implementation of this short-term incubation method could provide ID results on the day of blood culture-positivity detection and one day earlier than the conventional AST method. This simple method will be very useful for rapid ID and AST of bacteria from positive blood culture bottles in routine clinical practice. PMID:29401558
Ha, Jihye; Hong, Sung Kuk; Han, Geum Hee; Kim, Myungsook; Yong, Dongeun; Lee, Kyungwon
2018-05-01
Early and appropriate antibiotic treatment improves the clinical outcome of patients with septicemia; therefore, reducing the turn-around time for identification (ID) and antimicrobial susceptibility test (AST) results is essential. We established a method for rapid ID and AST using short-term incubation of positive blood culture broth samples on solid media, and evaluated its performance relative to that of the conventional method using two rapid ID systems and a rapid AST method. A total of 254 mono-microbial samples were included. Positive blood culture samples were incubated on blood agar plates for six hours and identified by the MicroFlex LT (Bruker Daltonics) and Vitek-MS (bioMeriéux) systems, followed by AST using the Vitek2 System (bioMeriéux). The correct species-level ID rates were 82.3% (209/254) and 78.3% (199/254) for the MicroFlex LT and Vitek-MS platforms, respectively. For the 1,174 microorganism/antimicrobial agent combinations tested, the rapid AST method showed total concordance of 97.8% (1,148/1,174) with the conventional method, with a very major error rate of 0.5%, major error rate of 0.7%, and minor error rate of 1.0%. Routine implementation of this short-term incubation method could provide ID results on the day of blood culture-positivity detection and one day earlier than the conventional AST method. This simple method will be very useful for rapid ID and AST of bacteria from positive blood culture bottles in routine clinical practice. © The Korean Society for Laboratory Medicine
ERIC Educational Resources Information Center
Woltemade, Christopher J.; Stanitski-Martin, Diane
2002-01-01
Undergraduate students compared Next Generation Weather Radar (NEXRAD) estimates of storm total precipitation to measurements from a network of 20 rain gauges. Student researchers gained valuable experience in field data collection, global positioning systems (GPS), geographic information systems (GIS), Internet data access and downloading,…
Code of Federal Regulations, 2014 CFR
2014-07-01
... PRIMARY DRINKING WATER REGULATIONS Revised Total Coliform Rule § 141.860 Violations. (a) E. coli MCL Violation. A system is in violation of the MCL for E. coli when any of the conditions identified in paragraphs (a)(1) through (a)(4) of this section occur. (1) The system has an E. coli-positive repeat sample...
Code of Federal Regulations, 2013 CFR
2013-07-01
... PRIMARY DRINKING WATER REGULATIONS Revised Total Coliform Rule § 141.860 Violations. (a) E. coli MCL Violation. A system is in violation of the MCL for E. coli when any of the conditions identified in paragraphs (a)(1) through (a)(4) of this section occur. (1) The system has an E. coli-positive repeat sample...
49 CFR 236.1005 - Requirements for Positive Train Control systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... be determined and reported as follows: (i) The traffic density threshold of 5 million gross tons... in rail traffic such as reductions in total traffic volume or cessation of passenger or PIH service... requirement to install PTC on a low density track segment where a PTC system is otherwise required by this...
49 CFR 236.1005 - Requirements for Positive Train Control systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... be determined and reported as follows: (i) The traffic density threshold of 5 million gross tons... in rail traffic such as reductions in total traffic volume to a level below 5 million gross tons... requirement to install PTC on a low density track segment where a PTC system is otherwise required by this...
49 CFR 236.1005 - Requirements for Positive Train Control systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... be determined and reported as follows: (i) The traffic density threshold of 5 million gross tons... in rail traffic such as reductions in total traffic volume to a level below 5 million gross tons... requirement to install PTC on a low density track segment where a PTC system is otherwise required by this...
49 CFR 236.1005 - Requirements for Positive Train Control systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... be determined and reported as follows: (i) The traffic density threshold of 5 million gross tons... in rail traffic such as reductions in total traffic volume to a level below 5 million gross tons... requirement to install PTC on a low density track segment where a PTC system is otherwise required by this...
Ionospheric Slant Total Electron Content Analysis Using Global Positioning System Based Estimation
NASA Technical Reports Server (NTRS)
Komjathy, Attila (Inventor); Mannucci, Anthony J. (Inventor); Sparks, Lawrence C. (Inventor)
2017-01-01
A method, system, apparatus, and computer program product provide the ability to analyze ionospheric slant total electron content (TEC) using global navigation satellite systems (GNSS)-based estimation. Slant TEC is estimated for a given set of raypath geometries by fitting historical GNSS data to a specified delay model. The accuracy of the specified delay model is estimated by computing delay estimate residuals and plotting a behavior of the delay estimate residuals. An ionospheric threat model is computed based on the specified delay model. Ionospheric grid delays (IGDs) and grid ionospheric vertical errors (GIVEs) are computed based on the ionospheric threat model.
The Transverse Acetabular Ligament as an Intraoperative Guide to Cup Abduction.
Hiddema, Willem B; van der Merwe, Johan F; van der Merwe, Werner
2016-07-01
The success of a total hip arthroplasty relies on optimal acetabular cup placement to ensure mating of the femoral head and acetabular cup throughout all positions of the hip joint. Poor cup placement is associated with dislocation, impingement, microseparation, component loosening, and accelerated wear due to rim loading. This study examined a novel method of using the transverse acetabular ligament (TAL) to guide cup inclination during primary total hip arthroplasty. A descriptive study using 16 hips from 9 cadavers. A computer navigation system measured inclination and version of the acetabular component in 3 positions with the lower edge of cup: (1) flush with, (2) 5 mm proximal to, and (3) 5 mm distal to free border of the TAL. The median inclination angles were 44° in position (1), 30° in position (2), and 64° in position (3). The median anteversion angle for all positions was 19°. Cup inclination was acceptable when the lower edge of the cup was flush or within 5 mm proximal to the TAL. Copyright © 2016 Elsevier Inc. All rights reserved.
Bahador, Fateme; Sharifian, Roxana; Farhadi, Payam; Jafari, Abdosaleh; Nematolahi, Mohtram; Shokrpour, Nasrin
This study aimed to develop and test a research model that examined 7effective factors on the effectiveness of laboratory information system (LIS) through strategic planning. This research was carried out on total laboratory staff, information technology staff, and laboratory managers in Shiraz (a city in the south of Iran) teaching hospitals by structural equation modeling approach in 2015. The results revealed that there was no significant positive relationship between decisions based on cost-benefit analysis and LIS functionality with LIS effectiveness, but there was a significant positive relationship between other factors and LIS effectiveness. As expected, high levels of strategic information system planning result in increasing LIS effectiveness. The results also showed that the relationship between cost-benefit analysis, LIS functionality, end-user involvement, and information technology-business alignment with strategic information system planning was significant and positive.
False-Positive Cryptococcal Antigen Test Associated with Use of BBL Port-A-Cul Transport Vials▿
Wilson, Deborah A.; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S.; Procop, Gary W.
2011-01-01
A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed. PMID:21159939
False-positive cryptococcal antigen test associated with use of BBL Port-a-Cul transport vials.
Wilson, Deborah A; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S; Procop, Gary W
2011-02-01
A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed.
NASA Technical Reports Server (NTRS)
Bassiri, Sassan; Hajj, George A.
1993-01-01
Natural and man-made events like earthquakes and nuclear explosions launch atmospheric gravity waves (AGW) into the atmosphere. Since the particle density decreases exponentially with height, the gravity waves increase exponentially in amplitude as they propagate toward the upper atmosphere and ionosphere. As atmospheric gravity waves approach the ionospheric heights, the neutral particles carried by gravity waves collide with electrons and ions, setting these particles in motion. This motion of charged particles manifests itself by wave-like fluctuations and disturbances that are known as traveling ionospheric disturbances (TID). The perturbation in the total electron content due to TID's is derived analytically from first principles. Using the tilted dipole magnetic field approximation and a Chapman layer distribution for the electron density, the variations of the total electron content versus the line-of-sight direction are numerically analyzed. The temporal variation associated with the total electron content measurements due to AGW's can be used as a means of detecting characteristics of the gravity waves. As an example, detection of tsunami generated earthquakes from their associated atmospheric gravity waves using the Global Positioning System is simulated.
Ahmed, Mohamed O; Baptiste, Keith E; Daw, Mohamed A; Elramalli, Asma K; Abouzeed, Yousef M; Petersen, Andreas
2017-09-01
The purpose of the study was to investigate the molecular characteristics of meticillin-resistant Staphylococcus aureus (MRSA) isolated from clinical sources in Tripoli, Libya. A total of 95 MRSA strains collected at the Tripoli medical Centre were investigated by spa typing and identification of the Panton-Valentine Leukocidin (pvl) genes. A total of 26 spa types were characterized and distributed among nine clonal complexes; CC5 (n=32), CC80 (n=18), CC8 (n=17) and CC22 (n=12) were the most prevalent clonal complexes. In total, 34% of the isolates were positive for PVL. This study demonstrated the presence of CA-MRSA and pvl positive strains in hospital settings and underlines the importance of using molecular typing to investigate the epidemiology of MRSA. Preventative measures and surveillance systems are needed to control and minimize the spread of MRSA in the Libyan health care system. Copyright © 2017 International Society for Chemotherapy of Infection and Cancer. Published by Elsevier Ltd. All rights reserved.
Feasibility Study for an Autonomous UAV - Magnetometer System
2007-11-01
collect data from multiple magnetometers at high sampling rates (~100 Hz), and associated with these acquisition systems are highly accurate...component for an UAV helicopter- magnetometer system is the ability to have precise positioning (both for flightpath execution and for data acquisition...discussed under section 6.3. Figure 6.11 shows the fluxgate data used to compensate a total field magnetometer as previously described. The red
Ter Borg, Evert-Jan; Kelder, Johannes Cornelis
2017-07-01
To test the hypothesis that systemic auto-antibodies or hypergammaglobulinemia are related to the prevalence of extra-glandular tissue organ damage (EGOD) in primary Sjögren's syndrome (SS). A real practice-based investigation of a relatively large (n = 110) Dutch cohort of primary SS patients systematically followed up in a large non-academic hospital. After a follow up of mean 8.2 years a significant correlation was found between disease duration and the prevalence of EGOD. We did not observe a relationship between the total number or type of systemic auto-antibodies or hypergammaglobulinemia and the total number of EGOD. However, there was a correlation between the prevalence of polyneuropathy (PNP) and antinuclear antibodies (ANA) as well as anti-Ro/SS-A positivity and there was an inverse relationship between the presence of anti-Ro/SS-A antibodies and primary biliary cirrhosis (PBC). All PBC cases were anti-Ro/SS-A and anti-La/SS-B negative but ANA positive. There was a trend for a higher occurrence of pleuro-pulmonary disease in the ANA negative cases. Although we did not find a relationship between the total number or type of systemic auto-antibodies and the total number of EGOD, there were correlations between specific systemic auto-antibodies and specific types of EGOD. The presence of ANA and anti-Ro/SS-A was associated with the occurrence of PNP, as well as was the absence of anti-Ro/SS-A with PBC. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.
Malliet, Nicolas; Andrade, Jason G; Khairy, Paul; Thanh, Hien Kiem Nguyen; Venier, Sandrine; Dubuc, Marc; Dyrda, Katia; Guerra, Peter; Mondésert, Blandine; Rivard, Léna; Tadros, Rafik; Talajic, Mario; Thibault, Bernard; Roy, Denis; Macle, Laurent
2015-07-01
Fluoroscopic guidance is used to position catheters during cardiac ablation. We evaluated the impact of a novel nonfluoroscopic sensor-guided electromagnetic navigation system (MG) on radiation exposure during catheter ablation of atrial fibrillation (AF) or atrial flutter (AFL). A total of 134 consecutive patients referred for ablation of AF (n = 44) or AFL (n = 90) ablation were prospectively enrolled. In one group the MG system was used for nonfluoroscopic catheter positioning, whereas in the conventional group standard fluoroscopy was utilized. Fluoroscopy times were assessed for each stage of procedure and total radiation exposure was quantified. Patient characteristics were similar between the groups. The procedural end point was achieved in all. Median (interquartile range [IQR]) fluoroscopy times were 12.5 minutes (7.6, 17.4) MG group versus 21.5 minutes (15.3, 23.0) conventional group (P < 0.0001) for AF ablation, and 0.8 minutes (0.4, 2.5) MG group versus 9.9 minutes (5.1, 22.5) conventional group (P < 0.0001) for AFL ablation. Median (IQR) total radiation exposure (μGy·m(2)) was 1,107 (906, 2,033) MG group versus 2,835 (1,688, 3,855) conventional group (P = 0.0001) for AF ablation, and 161 (65, 537) MG group versus 1,651 (796, 4,569) conventional group (P < 0.0001) for AFL ablation. No difference in total procedural time was seen. The use of a novel nonfluoroscopic catheter tracking system is associated with a significant reduction in radiation exposure during AF and AFL ablation (61% and 90% reduction, respectively). In the era of heightened awareness of the importance of radiation reduction, this system represents a safe and efficient tool to decrease radiation exposure during electrophysiological ablation procedures. ©2015 Wiley Periodicals, Inc.
Poster - 49: Assessment of Synchrony respiratory compensation error for CyberKnife liver treatment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Ming; Cygler,
The goal of this work is to quantify respiratory motion compensation errors for liver tumor patients treated by the CyberKnife system with Synchrony tracking, to identify patients with the smallest tracking errors and to eventually help coach patient’s breathing patterns to minimize dose delivery errors. The accuracy of CyberKnife Synchrony respiratory motion compensation was assessed for 37 patients treated for liver lesions by analyzing data from system logfiles. A predictive model is used to modulate the direction of individual beams during dose delivery based on the positions of internally implanted fiducials determined using an orthogonal x-ray imaging system and themore » current location of LED external markers. For each x-ray pair acquired, system logfiles report the prediction error, the difference between the measured and predicted fiducial positions, and the delivery error, which is an estimate of the statistical error in the model overcoming the latency between x-ray acquisition and robotic repositioning. The total error was calculated at the time of each x-ray pair, for the number of treatment fractions and the number of patients, giving the average respiratory motion compensation error in three dimensions. The 99{sup th} percentile for the total radial error is 3.85 mm, with the highest contribution of 2.79 mm in superior/inferior (S/I) direction. The absolute mean compensation error is 1.78 mm radially with a 1.27 mm contribution in the S/I direction. Regions of high total error may provide insight into features predicting groups of patients with larger or smaller total errors.« less
Pérez-de la Cruz, S
One of the consequences of poor postural control in children with cerebral palsy is hip dislocation. This is due to the lack of weight-bearing in the sitting and standing positions. Orthotic aids can be used to prevent onset and/or progression. The aim of this study is to analyse the effectiveness of positioning systems in achieving postural control in patients with cerebral palsy, and discuss these findings with an emphasis on what may be of interest in the field of neurology. We selected a total of 18 articles on interventions in cerebral palsy addressing posture and maintenance of ideal postures to prevent deformities and related problems. The main therapeutic approaches employed combinations of botulinum toxin and orthoses, which reduced the incidence of hip dislocation although these results were not significant. On the other hand, using positioning systems in 3 different positions decreases use of botulinum toxin and surgery in children under 5 years old. The drawback is that these systems are very uncomfortable. Postural control systems helps control hip deformities in children with cerebral palsy. However, these systems must be used for prolonged periods of time before their effects can be observed. Copyright © 2015 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.
Sub-micron resolution rf cavity beam position monitor system at the SACLA XFEL facility
NASA Astrophysics Data System (ADS)
Maesaka, H.; Ego, H.; Inoue, S.; Matsubara, S.; Ohshima, T.; Shintake, T.; Otake, Y.
2012-12-01
We have developed and constructed a C-band (4.760 GHz) rf cavity beam position monitor (RF-BPM) system for the XFEL facility at SPring-8, SACLA. The demanded position resolution of the RF-BPM is less than 1 μm, because an electron beam and x-rays must be overlapped within 4 μm precision in the undulator section for sufficient FEL interaction between the electrons and x-rays. In total, 57 RF-BPMs, including IQ demodulators and high-speed waveform digitizers for signal processing, were produced and installed into SACLA. We evaluated the position resolutions of 20 RF-BPMs in the undulator section by using a 7 GeV electron beam having a 0.1 nC bunch charge. The position resolution was measured to be less than 0.6 μm, which was sufficient for the XFEL lasing in the wavelength region of 0.1 nm, or shorter.
Results of the long range position-determining system tests. [Field Army system
NASA Technical Reports Server (NTRS)
Rhode, F. W.
1973-01-01
The long range position-determining system (LRPDS) has been developed by the Corps of Engineers to provide the Field Army with a rapid and accurate positioning capability. The LRPDS consists of an airborne reference position set (RPS), up to 30 ground based positioning sets (PS), and a position computing central (PCC). The PCC calculates the position of each PS based on the range change information provided by each Set. The positions can be relayed back to the PS again via RPS. Each PS unit contains a double oven precise crystal oscillator. The RPS contains a Hewlett-Packard cesium beam standard. Frequency drifts and off-sets of the crystal oscillators are taken in account in the data reduction process. A field test program was initiated in November 1972. A total of 54 flights were made which included six flights for equipment testing and 48 flights utilizing the field test data reduction program. The four general types of PS layouts used were: short range; medium range; long range; tactical configuration. The overall RMS radial error of the unknown positions varied from about 2.3 meters for the short range to about 15 meters for the long range. The corresponding elevation RMS errors vary from about 12 meters to 37 meters.
NASA Astrophysics Data System (ADS)
Opshaug, Guttorm Ringstad
There are times and places where conventional navigation systems, such as the Global Positioning System (GPS), are unavailable due to anything from temporary signal occultations to lack of navigation system infrastructure altogether. The goal of the Leapfrog Navigation System (LNS) is to provide localized positioning services for such cases. The concept behind leapfrog navigation is to advance a group of navigation units teamwise into an area of interest. In a practical 2-D case, leapfrogging assumes known initial positions of at least two currently stationary navigation units. Two or more mobile units can then start to advance into the area of interest. The positions of the mobiles are constantly being calculated based on cross-range distance measurements to the stationary units, as well as cross-ranges among the mobiles themselves. At some point the mobile units stop, and the stationary units are released to move. This second team of units (now mobile) can then overtake the first team (now stationary) and travel even further towards the common goal of the group. Since there always is one stationary team, the position of any unit can be referenced back to the initial positions. Thus, LNS provides absolute positioning. I developed navigation algorithms needed to solve leapfrog positions based on cross-range measurements. I used statistical tools to predict how position errors would grow as a function of navigation unit geometry, cross-range measurement accuracy and previous position errors. Using this knowledge I predicted that a 4-unit Leapfrog Navigation System using 100 m baselines and 200 m leap distances could travel almost 15 km before accumulating absolute position errors of 10 m (1sigma). Finally, I built a prototype leapfrog navigation system using 4 GPS transceiver ranging units. I placed the 4 units in the vertices a 10m x 10m square, and leapfrogged the group 20 meters forwards, and then back again (40 m total travel). Average horizontal RMS position errors never exceeded 16 cm during these field tests.
Code of Federal Regulations, 2013 CFR
2013-07-01
... WATER REGULATIONS Revised Total Coliform Rule § 141.856 Routine monitoring requirements for subpart H... coliform-positive sample taken under the provisions of this section, systems must comply with the repeat... coliform treatment technique triggers specified in § 141.859 have been exceeded. If any trigger has been...
Autonomous Navigation of the SSTI/Lewis Spacecraft Using the Global Positioning System (GPS)
NASA Technical Reports Server (NTRS)
Hart, R. C.; Long, A. C.; Lee, T.
1997-01-01
The National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) is pursuing the application of Global Positioning System (GPS) technology to improve the accuracy and economy of spacecraft navigation. High-accuracy autonomous navigation algorithms are being flight qualified in conjunction with GSFC's GPS Attitude Determination Flyer (GADFLY) experiment on the Small Satellite Technology Initiative (SSTI) Lewis spacecraft, which is scheduled for launch in 1997. Preflight performance assessments indicate that these algorithms can provide a real-time total position accuracy of better than 10 meters (1 sigma) and velocity accuracy of better than 0.01 meter per second (1 sigma), with selective availability at typical levels. This accuracy is projected to improve to the 2-meter level if corrections to be provided by the GPS Wide Area Augmentation System (WAAS) are included.
Canopy and seasonal profiles of nitrate reductase in soybeans
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harper, J.E.; Hageman, R.H.
1972-01-01
Nitrate reductase activity of soybeans (Glycine max L. Merr.) was evaluated in soil plots and outdoor hydroponic gravel culture systems throughout the growing season. Nitrate reductase profiles within the plant canopy were also established. Mean activity per gram fresh weight per hour of the entire plant canopy was highest in the seedling stage while total activity (activity per gram fresh weight per hour times the total leaf weight) reached a maximum when plants were in the full bloom to midpod fill stage. Nitrate reductase activity per gram fresh weight per hour was highest in the uppermost leaf just prior tomore » full expansion and declined with leaf positions lower in the canopy. Total nitrate reductase activity per leaf was also highest in the uppermost fully expanded leaf during early growth stages. Maximum total activity shifted to leaf positions lower in the plant canopy with later growth stages. Nitrate reductase activity of soybeans grown in hydroponic systems was significantly higher than activity of adjacent soil grown plants at later growth stages, which suggested that under normal field conditions the potential for nitrate utilization may not be realized. Nitrate reductase activity per gram fresh weight per hour and nitrate content were positively correlated over the growing season with plants grown in either soil or solution culture. Computations based upon the nitrate reductase assay of plants grown in hydroponics indicated that from 1.7 to 1.8 grams N could have been supplied to the plant via the nitrate reductase process. 11 references, 9 figures, 3 tables.« less
Antiphospholipid antibodies and non-thrombotic manifestations of systemic lupus erythematosus.
İlgen, U; Yayla, M E; Ateş, A; Okatan, İ E; Yurteri, E U; Torgutalp, M; Keleşoğlu, A B D; Turgay, T M; Kınıklı, G
2018-04-01
Objectives The aim of this study was to investigate the association between antiphospholipid antibodies and non-thrombotic and non-gestational manifestations of systemic lupus erythematosus. Methods Systemic lupus erythematosus patients with persistently positive antiphospholipid antibodies or lupus anticoagulant were identified and grouped as systemic lupus erythematosus with antiphospholipid syndrome (SLE-APS), systemic lupus erythematosus with positive antiphospholipid antibodies/lupus anticoagulant without antiphospholipid syndrome (SLE-aPL), and systemic lupus erythematosus with negative aPLs (SLE-No aPL). Groups were compared in terms of non-thrombotic systemic lupus erythematosus manifestations and laboratory features retrospectively. Results A total of 150 systemic lupus erythematosus patients, 26 with SLE-APS, 25 with SLE-aPL, and 99 with SLE-No aPL, were identified. Livedo reticularis, neurologic involvement, and thrombocytopenia were more common in antiphospholipid antibody positive systemic lupus erythematosus cases. Malar rash, arthritis, and pleuritis were more common in the SLE-No aPL, SLE-APS, and SLE-aPL groups, respectively. Positivity rates and titers of specific antiphospholipid antibodies did not differ between the SLE-APS and SLE-aPL groups. Conclusions Presence of antiphospholipid syndrome or persistent antiphospholipid antibodies may be related to non-thrombotic and non-gestational systemic lupus erythematosus manifestations. Patients with systemic lupus erythematosus plus antiphospholipid syndrome and persistent antiphospholipid antibodies without antiphospholipid syndrome also differ in terms of systemic lupus erythematosus manifestations.
Base drive for paralleled inverter systems
NASA Technical Reports Server (NTRS)
Nagano, S. (Inventor)
1980-01-01
In a paralleled inverter system, a positive feedback current derived from the total current from all of the modules of the inverter system is applied to the base drive of each of the power transistors of all modules, thereby to provide all modules protection against open or short circuit faults occurring in any of the modules, and force equal current sharing among the modules during turn on of the power transistors.
Relationship between red wine grades and phenolics. 1. Tannin and total phenolics concentrations.
Mercurio, Meagan D; Dambergs, Robert G; Cozzolino, Daniel; Herderich, Markus J; Smith, Paul A
2010-12-08
Measuring chemical composition is a common approach to support decisions about allocating foods and beverages to grades related to market value. Red wine is a particularly complex beverage, and multiple compositional attributes are needed to account for its sensory properties, including measurement of key phenolic components such as anthocyanins, total phenolics, and tannin, which are related to color and astringency. Color has been shown to relate positively to red wine grade; however, little research has been presented that explores the relationship between astringency-related components such as total phenolic or tannin concentration and wine grade. The aim of this research has been to investigate the relationship between the wine grade allocations of commercial wineries and total phenolic and tannin concentrations, respectively, in Australian Shiraz and Cabernet Sauvignon wines. Total phenolic and tannin concentrations were determined using the methyl cellulose precipitable (MCP) tannin assay and then compared to wine grade allocations made by winemaker panels during the companies' postvintage allocation process. Data were collected from wines produced by one Australian wine company over the 2005, 2006, and 2007 vintages and by a further two companies in 2007 (total wines = 1643). Statistical analysis revealed a positive trend toward higher wine grade allocation and wines that had higher concentrations of both total phenolics and tannin, respectively. This research demonstrates that for these companies, in general, Cabernet Sauvignon and Shiraz wines allocated to higher market value grades have higher total phenolics and higher tannin concentrations and suggests that these compositional parameters should be considered in the development of future multiparameter decision support systems for relevant commercial red wine grading processes. In addition, both tannin and total phenolics would ideally be included because although, in general, a positive relationship exists between the two parameters, this relationship does not hold for all wine styles.
Probe Scanning Support System by a Parallel Mechanism for Robotic Echography
NASA Astrophysics Data System (ADS)
Aoki, Yusuke; Kaneko, Kenta; Oyamada, Masami; Takachi, Yuuki; Masuda, Kohji
We propose a probe scanning support system based on force/visual servoing control for robotic echography. First, we have designed and formulated its inverse kinematics the construction of mechanism. Next, we have developed a scanning method of the ultrasound probe on body surface to construct visual servo system based on acquired echogram by the standalone medical robot to move the ultrasound probe on patient abdomen in three-dimension. The visual servo system detects local change of brightness in time series echogram, which is stabilized the position of the probe by conventional force servo system in the robot, to compensate not only periodical respiration motion but also body motion. Then we integrated control method of the visual servo with the force servo as a hybrid control in both of position and force. To confirm the ability to apply for actual abdomen, we experimented the total system to follow the gallbladder as a moving target to keep its position in the echogram by minimizing variation of reaction force on abdomen. As the result, the system has a potential to be applied to automatic detection of human internal organ.
Tamhankar, Anup Sunil; Jatal, Sudhir; Saklani, Avanish
2016-12-01
This study aims to assess the advantages of Da Vinci Xi system in rectal cancer surgery. It also assesses the initial oncological outcomes after rectal resection with this system from a tertiary cancer center in India. Robotic rectal surgery has distinct advantages over laparoscopy. Total robotic resection is increasing following the evolution of hybrid technology. The latest Da Vinci Xi system (Intuitive Surgical, Sunnyvale, USA) is enabled with newer features to make total robotic resection possible with single docking and single phase. Thirty-six patients underwent total robotic resection in a single phase and single docking. We used newer port positions in a straight line. Median distance from the anal verge was 4.5 cm. Median robotic docking time and robotic procedure time were 9 and 280 min, respectively. Median blood loss was 100 mL. One patient needed conversion to an open approach due to advanced disease. Circumferential resection margin and longitudinal resection margins were uninvolved in all other patients. Median lymph node yield was 10. Median post-operative stay was 7 days. There were no intra-operative adverse events. The latest Da Vinci Xi system has made total robotic rectal surgery feasible in single docking and single phase. With the new system, four arm total robotic rectal surgery may replace the hybrid technique of laparoscopic and robotic surgery for rectal malignancies. The learning curve for the new system appears to be shorter than anticipated. Early perioperative and oncological outcomes of total robotic rectal surgery with the new system are promising. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Automatic detection of ECG cable interchange by analyzing both morphology and interlead relations.
Han, Chengzong; Gregg, Richard E; Feild, Dirk Q; Babaeizadeh, Saeed
2014-01-01
ECG cable interchange can generate erroneous diagnoses. For algorithms detecting ECG cable interchange, high specificity is required to maintain a low total false positive rate because the prevalence of interchange is low. In this study, we propose and evaluate an improved algorithm for automatic detection and classification of ECG cable interchange. The algorithm was developed by using both ECG morphology information and redundancy information. ECG morphology features included QRS-T and P-wave amplitude, frontal axis and clockwise vector loop rotation. The redundancy features were derived based on the EASI™ lead system transformation. The classification was implemented using linear support vector machine. The development database came from multiple sources including both normal subjects and cardiac patients. An independent database was used to test the algorithm performance. Common cable interchanges were simulated by swapping either limb cables or precordial cables. For the whole validation database, the overall sensitivity and specificity for detecting precordial cable interchange were 56.5% and 99.9%, and the sensitivity and specificity for detecting limb cable interchange (excluding left arm-left leg interchange) were 93.8% and 99.9%. Defining precordial cable interchange or limb cable interchange as a single positive event, the total false positive rate was 0.7%. When the algorithm was designed for higher sensitivity, the sensitivity for detecting precordial cable interchange increased to 74.6% and the total false positive rate increased to 2.7%, while the sensitivity for detecting limb cable interchange was maintained at 93.8%. The low total false positive rate was maintained at 0.6% for the more abnormal subset of the validation database including only hypertrophy and infarction patients. The proposed algorithm can detect and classify ECG cable interchanges with high specificity and low total false positive rate, at the cost of decreased sensitivity for certain precordial cable interchanges. The algorithm could also be configured for higher sensitivity for different applications where a lower specificity can be tolerated. Copyright © 2014 Elsevier Inc. All rights reserved.
Accuracy and Reproducibility Using Patient-Specific Instrumentation in Total Ankle Arthroplasty.
Daigre, Justin; Berlet, Gregory; Van Dyke, Bryan; Peterson, Kyle S; Santrock, Robert
2017-04-01
Implant survivorship is dependent on accuracy of implantation and successful soft tissue balancing. System instrumentation for total ankle arthroplasty implantation has a key influence on surgeon accuracy and reproducibility. The purpose of this study was to determine the accuracy and reproducibility of implant position with patient-specific guides for total ankle arthroplasty across multiple surgeons at multiple facilities. This retrospective, multicenter study included 44 patients who received a total ankle implant (INBONE II Total Ankle System; Wright Medical Technology, Memphis, TN) using PROPHECY patient-specific guides from January 2012 to December 2014. Forty-four patients with an average age of 63.0 years underwent total ankle arthroplasty using this preoperative patient-specific system. Preoperative computed tomography (CT) scans were obtained to assess coronal plane deformity, assess mechanical and anatomic alignment, and build patient-specific guides that referenced bony anatomy. The mean preoperative coronal deformity was 4.6 ± 4.6 degrees (range, 14 degrees varus to 17 degrees valgus). The first postoperative weightbearing radiographs were used to measure coronal and sagittal alignment of the implant vs the anatomic axis of the tibia. In 79.5% of patients, the postoperative implant position of the tibia corresponded to the preoperative plan of the tibia within 3 degrees of the intended target, within 4 degrees in 88.6% of patients, and within 5 degrees in 100% of patients. The tibial component coronal size was correctly predicted in 98% of cases, whereas the talar component was correctly predicted in 80% of cases. The use of patient-specific instrumentation for total ankle arthroplasty provided reliable alignment and reproducibility in the clinical situation similar to that shown in cadaveric testing. This study has shown that the preoperative patient-specific instrumentation provided for accuracy and reproducibility of ankle arthroplasty implantation in a cohort across multiple surgeons and facilities. Level III, retrospective comparative series.
Schubert, Christian; Geser, Willi; Noisternig, Bianca; Fuchs, Dietmar; Welzenbach, Natalie; König, Paul; Schüßler, Gerhard; Ocaña-Peinado, Francisco M.; Lampe, Astrid
2012-01-01
Little is known about the dynamic characteristics of stress system activity during “life as it is lived”. Using as representative a study design as possible, this investigation sought to gain insights into this area. A healthy 25-year-old woman collected her entire urine over a period of 63 days in 12-h intervals (126 measurements) to determine cortisol and neopterin (immune activation marker) levels. In addition, she filled out questionnaires on emotional state and daily routine in 12-h intervals, and was interviewed weekly to identify emotionally negative and positive everyday incidents. Adjusted cross-correlational analyses revealed that stressful incidents were associated with cyclic response patterns in both urinary cortisol and urinary neopterin concentrations. Urinary cortisol levels first decreased 12–24 h after stressful incidents occurred (lag 1: −.178; p = 0.048) and then increased a total of 72–84 h later (lag 6: +.224; p = 0.013). Urinary neopterin levels first increased 0–12 h before the occurrence of stressful incidents (−lag 1: +.185; p = 0.040) and then decreased a total of 48–60 h following such stressors (lag 4: −.181; p = 0.044). Decreases in urinary neopterin levels were also found 24–36 and 48–60 h after increases in pensiveness (lag 2: −.215; p = 0.017) and depressiveness (lag 4: −.221; p = 0.014), respectively. Findings on emotionally positive incidents sharply contrasted with those dealing with negative experiences. Positive incidents were followed first by urinary cortisol concentration increases within 12 h (lag 0: +.290; p = 0.001) and then by decreases after a total of 60–72 h (lag 5: −.186; p = 0.039). Urinary neopterin levels first decreased 12–24 h before positive incidents occurred (−lag 2: −.233; p = 0.010) and then increased a total of 12–24 h following these incidents (lag 1: +.222; p = 0.014). As with previous investigations on patients with systemic lupus erythematosus (SLE), this study showed that stress system response can be considerably longer and more complex and differentiated than findings from conventional group studies have suggested. Further integrative single-case studies will need to be conducted in order to draw firm conclusions about stress system dynamics under real-life conditions. PMID:22403606
Gies, Franziska; Tschiedel, Eva; Felderhoff-Müser, Ursula; Rath, Peter-Michael; Steinmann, Joerg; Dohna-Schwake, Christian
2016-08-08
Antimicrobially pre-treated children with systemic inflammation often pose a diagnostic challenge to the physician. We aimed to evaluate the additional use of SeptiFast multiplex polymerase chain reaction (PCR) to identify causative pathogens in children with suspected systemic bacterial or fungal infection. Prospective observational study in 39 children with systemic inflammatory response syndrome (SIRS) under empiric antibiotic treatment. Primary outcome was the rate of positive blood cultures (BC), compared to the rate of positive SeptiFast (SF) results. In total, 14 SF-samples yielded positive results, compared to 4 positive BC (p < 0.05). All blood cultures and 13 of 14 positive SF-tests were considered infection. Median time for positive BC was 2 days, and time to definite result was 6 days, compared to 12 h for SF. Antimicrobial therapy was adapted in 7 of the 14 patients with positive SeptiFast, and in 3 of the 4 patients with positive BC. Best predictive power for positive SF shown by receiver-operating characteristic was demonstrated for procalcitonin PCT (Area under the curve AUC: 0.79), compared to C-reactive protein CRP (AUC: 0.51) and leukocyte count (AUC: 0.46). A procalcitonin threshold of 0.89 ng/ml yielded a sensitivity of 0.82 and a specifity of 0.7. Children with a positive SeptiFast result on day 0 had a significantly higher risk to require treatment on the Pediatric Intensive Care Unit or to be deceased on day 30 (Odds-Ratio 8.62 (CI 1.44-51.72). The additional testing with SeptiFast in antimicrobially pre-treated children with systemic inflammation enhances the rate of pathogen detection. The influence of multiplex PCR on clinically relevant outcome parameters has to be further evaluated. ( DRKS00004694).
Tsujikawa, Kenji; Kuwayama, Kenji; Miyaguchi, Hajime; Kanamori, Tatsuyuki; Iwata, Yuko T; Yoshida, Takemi; Inoue, Hiroyuki
2008-02-04
We tried to develop a library search system using a portable, attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectrometer for on-site identification of 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA) tablets. The library consisted of the spectra from mixtures of controlled drugs (e.g. MDMA and ketamine), adulterants (e.g. caffeine), and diluents (e.g. lactose). In the seven library search algorithms, the derivative correlation coefficient showed the best discriminant capability. This was enhanced by segmentation of the search area. The optimized search algorithm was validated by the positive (n=154, e.g. the standard mixtures containing the controlled drug, and the MDMA/MDA tablets confiscated) and negative samples (n=56, e.g. medicinal tablets). All validation samples except for four were judged truly. Final criteria for positive identification were decided on the basis of the results of the validation. In conclusion, a portable ATR-FT-IR spectrometer with our library search system would be a useful tool for on-site identification of amphetamine-type stimulant tablets.
Processing Satellite Data for Slant Total Electron Content Measurements
NASA Technical Reports Server (NTRS)
Stephens, Philip John (Inventor); Komjathy, Attila (Inventor); Wilson, Brian D. (Inventor); Mannucci, Anthony J. (Inventor)
2016-01-01
A method, system, and apparatus provide the ability to estimate ionospheric observables using space-borne observations. Space-borne global positioning system (GPS) data of ionospheric delay are obtained from a satellite. The space-borne GPS data are combined with ground-based GPS observations. The combination is utilized in a model to estimate a global three-dimensional (3D) electron density field.
The efficacy of the new SCD response compression system in the prevention of venous stasis.
Kakkos, S K; Szendro, G; Griffin, M; Daskalopoulou, S S; Nicolaides, A N
2000-11-01
The current commercially available sequential intermittent pneumatic compression device used for the prevention of deep venous thrombosis has a constant cycle of 11 seconds' compression and 60 seconds' deflation. This deflation period ensures that the veins are filled before the subsequent cycle begins. It has been suggested that in some positions (eg, semirecumbent or sitting) and with different patients (eg, those with venous reflux), refilling of the veins may occur much earlier than 60 seconds, and thus a more frequent cycle may be more effective in expelling blood proximally. The aim of the study was to test the effectiveness of a new sequential compression system (the SCD Response Compression System), which has the ability to detect the change in the venous volume and to respond by initiating the subsequent cycle when the veins are substantially full. In an open controlled trial at an academic vascular laboratory, the SCD Response Compression System was tested against the existing SCD Sequel Compression System in 12 healthy volunteers who were in supine, semirecumbent, and sitting positions. The refilling time sensed by the device was compared with that determined from recordings of femoral vein flow velocity by the use of duplex ultrasound scan. The total volume of blood expelled per hour during compression was compared with that produced by the existing SCD system in the same volunteers and positions. The refilling time determined automatically by the SCD Response Compression System varied from 24 to 60 seconds in the subjects tested, demonstrating individual patient variation. The refilling time (mean +/- SD) in the sitting position was 40.6 +/- 10. 0 seconds, which was significantly longer (P <.001) than that measured in the supine and semirecumbent positions, 33.8 +/- 4.1 and 35.6 +/- 4.9 seconds, respectively. There was a linear relationship between the duplex scan-derived refill time (mean of 6 readings per leg) and the SCD Response device-derived refill time (r = 0.85, P <. 001). The total volume of blood (mean +/- SD) expelled per hour by the existing SCD Sequel device in the supine, semirecumbent, and sitting positions was 2.23 +/- 0.90 L/h, 2.47 +/- 0.86 L/h, and 3.28 +/- 1.24 L/h, respectively. The SCD Response device increased the volume expelled to 3.92 +/- 1.60 L/h or a 76% increase (P =.001) in the supine position, to 3.93 +/- 1.55 L/h or a 59% increase (P =. 001) in the semirecumbent position, and to 3.97 +/- 1.42 L/h or a 21% increase (P =.026) in the sitting position. By achieving more appropriately timed compression cycles over time, the new SCD Response System is effective in preventing venous stasis by means of a new method that improves on the clinically documented effectiveness of the existing SCD system. Further studies testing its potential for improved efficacy in preventing deep venous thrombosis are justified.
Berliner, Jonathan L; Ortiz, Philippe A; Lee, Yuo-Yu; Miller, Theodore T; Westrich, Geoffrey H
2018-01-01
Improvements in device design have allowed for portable pneumatic compression devices (PPCDs). However, portability results in smaller pumps that move less blood. Additionally, although patients often stand when wearing PPCDs, few studies have evaluated the hemodynamic effects of PCDs while standing. A crossover study was performed to compare a PPCD (ActiveCare+S.F.T.; Medical Compression Systems, Or Akiva, Israel) to a stationary pneumatic compression device (SPCD) (VenaFlow; DJO Global, Carlsbad, CA) on hemodynamics in supine and standing positions among 2 cohorts composed of 10 controls and 10 total hip arthroplasty patients. Differences in baseline peak venous velocity (PVV), PVV with each PCD, and delta PVV with each PCD were assessed. A multivariate analysis was performed to examine differences between cohorts, devices, and position. In both positions, the SPCD demonstrated a larger change in PVV when compared to the PPCD (P < .001). The total hip arthroplasty group had a greater delta PVV while standing when considering both PCDs together (P < .001). When considering both cohorts, delta PVV was greater while standing, only when the SPCD was used (P < .001). There was no difference between standing and supine positions when the PPCD was used. The SPCD demonstrated a greater capacity to increase PPV in the supine and standing positions. The SPCD generated greater values of PVV and delta PVV in the standing position. Although these results demonstrate a difference between devices, it is important to establish the PVV necessary to prevent VTE before one is considered more effective. Copyright © 2017 Elsevier Inc. All rights reserved.
Juck, Gregory; Gonzalez, Verapaz; Allen, Ann-Christine Olsson; Sutzko, Meredith; Seward, Kody; Muldoon, Mark T
2018-04-27
The Romer Labs RapidChek ® Listeria monocytogenes test system (Performance Tested Method ℠ 011805) was validated against the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook (USDA-FSIS/MLG), U.S. Food and Drug Association Bacteriological Analytical Manual (FDA/BAM), and AOAC Official Methods of Analysis ℠ (AOAC/OMA) cultural reference methods for the detection of L. monocytogenes on selected foods including hot dogs, frozen cooked breaded chicken, frozen cooked shrimp, cured ham, and ice cream, and environmental surfaces including stainless steel and plastic in an unpaired study design. The RapidChek method uses a proprietary enrichment media system, a 44-48 h enrichment at 30 ± 1°C, and detects L. monocytogenes on an immunochromatographic lateral flow device within 10 min. Different L. monocytogenes strains were used to spike each of the matrixes. Samples were confirmed based on the reference method confirmations and an alternate confirmation method. A total of 140 low-level spiked samples were tested by the RapidChek method after enrichment for 44-48 h in parallel with the cultural reference method. There were 88 RapidChek presumptive positives. One of the presumptive positives was not confirmed culturally. Additionally, one of the culturally confirmed samples did not exhibit a presumptive positive. No difference between the alternate confirmation method and reference confirmation method was observed. The respective cultural reference methods (USDA-FSIS/MLG, FDA/BAM, and AOAC/OMA) produced a total of 63 confirmed positive results. Nonspiked samples from all foods were reported as negative for L. monocytogenes by all methods. Probability of detection analysis demonstrated no significant differences in the number of positive samples detected by the RapidChek method and the respective cultural reference method.
MEMS high-speed angular-position sensing system with rf wireless transmission
NASA Astrophysics Data System (ADS)
Sun, Winston; Li, Wen J.
2001-08-01
A novel surface-micromachined non-contact high-speed angular-position sensor with total surface area under 4mm2 was developed using the Multi-User MEMS Processes (MUMPs) and integrated with a commercial RF transmitter at 433MHz carrier frequency for wireless signal detection. Currently, a 2.3 MHz internal clock of our data acquisition system and a sensor design with a 13mg seismic mass is sufficient to provide visual observation of a clear sinusoidal response wirelessly generated by the piezoresistive angular-position sensing system within speed range of 180 rpm to around 1000 rpm. Experimental results showed that the oscillation frequency and amplitude are related to the input angular frequency of the rotation disk and the tilt angle of the rotation axis, respectively. These important results could provide groundwork for MEMS researchers to estimate how gravity influences structural properties of MEMS devices under different circumstances.
Gomaa, Noha; Nicolau, Belinda; Siddiqi, Arjumand; Tenenbaum, Howard; Glogauer, Michael; Quiñonez, Carlos
2017-09-14
To evaluate the extent of association between systemic inflammation and periodontal disease in American adults, and to assess whether socio-economic position mediated this relationship. We used data from the National Health and Nutrition Examination Survey (NHANES IV) (2001-2010). Systemic inflammation was defined by individual and aggregate (cumulative inflammatory load) biomarkers (C-reactive protein, white blood cell counts, neutrophil counts, and neutrophil:lymphocyte ratio). Loss of attachment and bleeding on probing were used to define periodontal disease. Poverty:income ratio and education were indicators of socio-economic position. Covariates included age, sex, ethnicity, smoking, alcohol, and attendance for dental treatment. Univariate and multivariable logistic regressions were constructed to assess the relationships of interest. In a total of 2296 respondents, biomarkers of systemic inflammation and cumulative inflammatory load were significantly associated with periodontal disease after adjusting for age, sex, and behavioural factors. Socio-economic position attenuated the association between markers of systemic inflammation and periodontal disease in the fully adjusted model. Socio-economic position partly explains how systemic inflammation and periodontal disease are coupled, and may thus have a significant role in the mechanisms linking oral and non-oral health conditions. It is of critical importance that the social and living conditions are taken into account when considering prevention and treatment strategies for inflammatory diseases, given what appears to be their impactful effect on disease processes.
NASA Technical Reports Server (NTRS)
Ho, C.; Wilson, B.; Mannucci, A.; Lindqwister, U.; Yuan, D.
1997-01-01
Global ionospheric mapping (GIM) is a new, emerging technique for determining global ionospheric TEC (total electron content) based on measurements from a worldwide network of Global Positioning System (GPS) receivers.
NASA Astrophysics Data System (ADS)
Leiva, Josue Nahun; Robbins, James; Saraswat, Dharmendra; She, Ying; Ehsani, Reza
2017-07-01
This study evaluated the effect of flight altitude and canopy separation of container-grown Fire Chief™ arborvitae (Thuja occidentalis L.) on counting accuracy. Images were taken at 6, 12, and 22 m above the ground using unmanned aircraft systems. Plants were spaced to achieve three canopy separation treatments: 5 cm between canopy edges, canopy edges touching, and 5 cm of canopy edge overlap. Plants were placed on two different ground covers: black fabric and gravel. A counting algorithm was trained using Feature Analyst®. Total counting error, false positives, and unidentified plants were reported for images analyzed. In general, total counting error was smaller when plants were fully separated. The effect of ground cover on counting accuracy varied with the counting algorithm. Total counting error for plants placed on gravel (-8) was larger than for those on a black fabric (-2), however, false positive counts were similar for black fabric (6) and gravel (6). Nevertheless, output images of plants placed on gravel did not show a negative effect due to the ground cover but was impacted by differences in image spatial resolution.
Bioactive Compounds in Potato Tubers: Effects of Farming System, Cooking Method, and Flesh Color
Czerko, Zbigniew; Zarzyńska, Krystyna; Borowska-Komenda, Monika
2016-01-01
We investigated the effect of cultivation system (conventional or organic), cooking method, and flesh color on the contents of ascorbic acid (AA) and total phenolics (TPs), and on total antioxidant activity (Trolox equivalents, TE) in Solanum tuberosum (potato) tubers. The research material, consisting of 4 potato cultivars, was grown in experimental fields, using organic and conventional systems, at the experimental station in 2012 and 2013. The analysis showed that organically grown potatoes with creamy, light yellow, and yellow flesh had significantly higher TPs than did potatoes grown conventionally. Flesh color and cooking method also affected AA. The greatest losses of AA occurred in yellow-fleshed potatoes grown conventionally and cooked in the microwave; such losses were not observed in potatoes grown organically. A dry cooking method (baking in a microwave) increased the TP contents in potatoes by about 30%, regardless of the flesh color and the production system. TE was significantly higher in organically grown potatoes (raw and cooked in a steamer) than in conventionally grown potatoes. TE and AA contents showed a significant positive correlation, but only in potatoes from the organic system [R2 = 0.686]. By contrast, the positive correlation between TE and TPs was observed regardless of the production system. Therefore, we have identified the effects of farming system, cooking method, and flesh color on the contents of bioactive compounds in potato tubers. PMID:27139188
Smith, Tamara; Krometis, Leigh-Anne H; Hagedorn, Charles; Lawrence, Annie H; Benham, Brian; Ling, Erin; Ziegler, Peter; Marmagas, Susan West
2014-12-01
Over 1.7 million Virginians rely on private water sources to provide household water. The heaviest reliance on these systems occurs in rural areas, which are often underserved with respect to available financial resources and access to environmental health education. This study aimed to identify potential associations between concentrations of fecal indicator bacteria (FIB) (coliforms, Escherichia coli) in over 800 samples collected at the point-of-use from homes with private water supply systems and homeowner-provided demographic data (household income and education). Of the 828 samples tested, 349 (42%) of samples tested positive for total coliform and 55 (6.6%) tested positive for E. coli. Source tracking efforts targeting optical brightener concentrations via fluorometry and the presence of a human-specific Bacteroides marker via quantitative real-time polymerase chain reaction (qPCR) suggest possible contamination from human septage in over 20 samples. Statistical methods implied that household income has an association with the proportion of samples positive for total coliform, though the relationship between education level and FIB is less clear. Further exploration of links between demographic data and private water quality will be helpful in building effective strategies to improve rural drinking water quality.
Evaluation of negative results of BacT/Alert 3D automated blood culture system.
Kocoglu, M Esra; Bayram, Aysen; Balci, Iclal
2005-06-01
Although automated continuous-monitoring blood culture systems are both rapid and sensitive, false-positive and false-negative results still occur. The objective of this study, then, was to evaluate negative results occurring with BacT/Alert 3D blood culture systems. A total of 1032 samples were cultured with the BacT/Alert 3D automated blood culture system, using both aerobic (FA) and anaerobic (FN) [corrected] media, and 128 of these samples yielded positive results. A total of 904 negative blood samples were then subcultured in 5% sheep blood agar, eosin methylene blue, chocolate agar, and sabouraud-dextrose agar. Organisms growing on these subcultures were subsequently identified using both Vitek32 (bioMerieux, Durham, NC) and conventional methods. Twenty four (2.6%) of the 904 subcultures grew on the subculture media. The majority (83.3%) of these were determined to be gram-positive microorganisms. Fourteen (58.3%) were coagulase-negative staphylococci, two (8.3%) were Bacillus spp., one (4.2%) was Staphylococcus aureus, and one (4.2%) was identified as Enterococcus faecium. Streptococcus pneumoniae and Neisseria spp. were isolated together in two (8.3%) vials. Gram-negative microorganisms comprised 12.5% of the subcultures, of which two (8.3%) were found to be Pseudomonas aeruginosa, and one (4.2%) was Pseudomonas fluorescens. The other isolate (4.2%) was identified as Candida albicans. We conclude that the subculture of negative results is valuable in the BacT/Alert 3D system, especially in situations in which only one set of blood cultures is taken.
Asteroids Search Results in Large Photographic Sky Surveys
NASA Astrophysics Data System (ADS)
Shatokhina, S. V.; Kazantseva, L. V.; Yizhakevych, O. M.; Eglitis, I.; Andruk, V. M.
Photographic observations of XX century contained numerous and varied information about all objects and events of the Universe fixed on plates. The original and interesting observations of small bodies of the Solar system in previous years can be selected and used for various scientific tasks. Existing databases and online services can help make such selection easily and quickly. The observations of chronologically earlier ppositions, photometric evaluation of brightness for long periods of time allow refining the orbits of asteroids and identifying various non-stationaries. Photographic observations of Northern Sky Survey project and observations of clusters in UBVR bands were used for global search for small bodies of Solar system. Total we founded 2486 positions of asteroids and 13 positions of comets. All positions were compared with ephemeris. It was found that 80 positions of asteroids have a moment of observation preceding their discovery, and 19 of them are chronologically the earliest observations of these asteroids in the world.
Hindocha, Sandip; Stanley, John K.; Watson, James Stewart
2007-01-01
There are few objective staging systems to assess severity of Dupuytren’s disease (DD). Previous methods to assess severity of DD were based primarily on the degree of contracture of an affected digit measured using a goniometer. Nonetheless, this method of assessment alone may be incomplete, and other factors should be considered. White (n = 92) patients diagnosed with DD from northwest of England were assessed for DD. Objective criteria for evaluating severity incorporated quantified variables. The revised severity stage was correlated to a known staging system of DD (Tubiana’s staging system) which measures total flexion deformity for a single affected digit. Total revised severity staging scores ranged between 4 and 53 (mean = 18.7) and revealed significant positive correlation to Tubiana’s original staging system (r2 = 0.8, p < 0.001). There was significant difference between severity staging scores in those with a positive family history compared to those without (p < 0.01). In current practice, often, the degree of contracture in an affected digit is used solely as a measure of disease severity. Additional objective clinical information may provide useful prognostic indices for disease progression as well as postoperative outcome. PMID:18780081
Li, Xv; Li, Chuantao
2018-05-01
Changes in intestinal flora in obese patients and intravascular C-reactive protein (CRP), interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) and coronary heart disease (CHD) were analyzed. A total of 75 cases of obese patients were divided into obesity (OB) alone (n=40) and OB with CHD group (n=35). There was no statistically significant difference in age, sex, pre-existing basic diabetes, history of hypertension, and body mass index (P>0.05). Results showed that total bacterial load of CHD was obviously higher than that of OB group. The uric acid decomposed by intestinal flora (IFUA) and blood uric acid levels in CHD were higher than those in OB group, but the fecal uric acid level was lower than that of OB group (P<0.05). Levels of inflammatory factors in CHD, were significantly higher than those in OB group (P<0.05). Correlation analyses showed that the intestinal flora total load and CRP were positively correlated (r=0.793, P<0.001). Intestinal flora and Gensini score were also positively related to total load (r=0.893, P=0.893). Furthermore, CRP and Gensini score were positively related (r=0.796, P<0.796). IFUA and Gensini score were positively related to (r=0.647, P<0.001). Over-reaction in the flammation system in obese patients may lead to intestinal flora disorder, disturbance and also increased levels of IFUA and inflammatory factors.
Improving Echo-Guided Procedures Using an Ultrasound-CT Image Fusion System.
Diana, Michele; Halvax, Peter; Mertz, Damien; Legner, Andras; Brulé, Jean-Marcel; Robinet, Eric; Mutter, Didier; Pessaux, Patrick; Marescaux, Jacques
2015-06-01
Image fusion between ultrasound (US) and computed tomography (CT) scan or magnetic resonance can increase operator accuracy in targeting liver lesions, particularly when those are undetectable with US alone. We have developed a modular gel to simulate hepatic solid lesions for educational purposes in imaging and minimally invasive ablation techniques. We aimed to assess the impact of image fusion in targeting artificial hepatic lesions during the hands-on part of 2 courses (basic and advanced) in hepatobiliary surgery. Under US guidance, 10 fake tumors of various sizes were created in the livers of 2 pigs, by percutaneous injection of a biocompatible gel engineered to be hyperdense on CT scanning and barely detectable on US. A CT scan was obtained and a CT-US image fusion was performed using the ACUSON S3000 US system (Siemens Healthcare, Germany). A total of 12 blinded course attendants, were asked in turn to perform a 10-minute liver scan with US alone followed by a 10-minute scan using image fusion. Using US alone, the expert managed to identify all lesions successfully. The true positive rate for course attendants with US alone was 14/36 and 2/24 in the advanced and basic courses, respectively. The total number of false positives identified was 26. With image fusion, the rate of true positives significantly increased to 31/36 (P < .001) in the advanced group and 16/24 in the basic group (P < .001). The total number of false positives, considering all participants, decreased to 4 (P < .001). Image fusion significantly increases accuracy in targeting hepatic lesions and might improve echo-guided procedures. © The Author(s) 2015.
Three dimensional imaging detector employing wavelength-shifting optical fibers
Worstell, William A.
1997-01-01
A novel detector element structure and method for its use is provided. In a preferred embodiment, one or more inorganic scintillating crystals are coupled through wavelength shifting optical fibers (WLSFs) to position sensitive photomultipliers (PS-PMTs). The superior detector configuration in accordance with this invention is designed for an array of applications in high spatial resolution gamma ray sensing with particular application to SPECT, PET and PVI imaging systems. The design provides better position resolution than prior art devices at a lower total cost. By employing wavelength shifting fibers (WLSFs), the sensor configuration of this invention can operate with a significant reduction in the number of photomultipliers and electronics channels, while potentially improving the resolution of the system by allowing three dimensional reconstruction of energy deposition positions.
Three dimensional imaging detector employing wavelength-shifting optical fibers
Worstell, W.A.
1997-02-04
A novel detector element structure and method for its use is provided. In a preferred embodiment, one or more inorganic scintillating crystals are coupled through wavelength shifting optical fibers (WLSFs) to position sensitive photomultipliers (PS-PMTs). The superior detector configuration in accordance with this invention is designed for an array of applications in high spatial resolution gamma ray sensing with particular application to SPECT, PET and PVI imaging systems. The design provides better position resolution than prior art devices at a lower total cost. By employing wavelength shifting fibers (WLSFs), the sensor configuration of this invention can operate with a significant reduction in the number of photomultipliers and electronics channels, while potentially improving the resolution of the system by allowing three dimensional reconstruction of energy deposition positions. 11 figs.
Observed TEC Anomalies by GNSS Sites Preceding the Aegean Sea Earthquake of 2014
NASA Astrophysics Data System (ADS)
Ulukavak, Mustafa; Yal&ccedul; ınkaya, Mualla
2016-11-01
In recent years, Total Electron Content (TEC) data, obtained from Global Navigation Satellites Systems (GNSS) receivers, has been widely used to detect seismo-ionospheric anomalies. In this study, Global Positioning System - Total Electron Content (GPS-TEC) data were used to investigate ionospheric abnormal behaviors prior to the 2014 Aegean Sea earthquake (40.305°N 25.453°E, 24 May 2014, 09:25:03 UT, Mw:6.9). The data obtained from three Continuously Operating Reference Stations in Turkey (CORS-TR) and two International GNSS Service (IGS) sites near the epicenter of the earthquake is used to detect ionospheric anomalies before the earthquake. Solar activity index (F10.7) and geomagnetic activity index (Dst), which are both related to space weather conditions, were used to analyze these pre-earthquake ionospheric anomalies. An examination of these indices indicated high solar activity between May 8 and 15, 2014. The first significant increase (positive anomalies) in Vertical Total Electron Content (VTEC) was detected on May 14, 2014 or 10 days before the earthquake. This positive anomaly can be attributed to the high solar activity. The indices do not imply high solar or geomagnetic activity after May 15, 2014. Abnormal ionospheric TEC changes (negative anomaly) were observed at all stations one day before the earthquake. These changes were lower than the lower bound by approximately 10-20 TEC unit (TECU), and may be considered as the ionospheric precursor of the 2014 Aegean Sea earthquake
From Empiricism to Total Quality Management in Greek Education
NASA Astrophysics Data System (ADS)
Karavasilis, Ioannis; Samoladas, Ioannis; Nedos, Apostolos
Nowadays the education system in Greece moves towards democratization and decentralization. School unit is the cell and the base of the education system. Principal's role is highly demanding, multi-dimensional, and a critical determinant of school performance and effectiveness. The paper proposes an effective organizational plan of school units in Primary Education based on basic administration processes and Total Quality Management. Using theory of emotional intelligence and Blake-Mouton's grid it emphasizes the impact of Principal's leadership on democratizing the school unit, on creating a safe and secure environment and positive school climate and motivating teachers committee to participate in the decision making process.
NASA Technical Reports Server (NTRS)
Hughes, Mark S.; Hebert, Phillip W.; Davis, Dawn M.; Jensen, Scott L.; Abell, Frederick K., Jr.
2004-01-01
The John C. Stennis Space Center (SSC) provides test operations services to a variety of customers, including NASA, DoD, and commercial enterprises for the development of current and next-generation rocket propulsion systems. Many of these testing services are provided in the E-Complex test facilities composed of three active test stands (E1, E2, & E3) and 7 total test positions. Each test position is outfitted with unique sets of data acquisition and controls hardware and software that record both facility and test article data and enable safe operation of the test facility. This paper addresses each system in more detail including efforts to upgrade hardware and software.
Huang, Wenting; Lv, Ning; Ying, Jianming; Qiu, Tian; Feng, Xiaoli
2014-01-01
A new category, “EBV positive T-cell lymphoproliferative disorders (LPD) of childhood”, was proposed in the 2008 World Health Organization’s (WHO) classifications of lymphoma. This series of lymphoproliferative disorders is rare. There are two major types of this series of disorders: systemic EBV positive T-cell LPD of childhood and hydroa vacciniforme-like lymphoma (HVLL). In this study, we describe the distinct features of four cases of EBV positive T-cell LPD of childhood in China. Two were systemic EBV positive T-cell LPD of childhood, one was HVLL and one was chronic active EBV (CAEBV). The main manifestations were lymphadenopathy, fever, hepatosplenomegaly and skin rashes. The structure of the lymph nodes in the patients ranged from preserved to partially or totally destroyed. Small- to medium-sized, atypical T cells had infiltrated the lymph nodes. In HVLL, the neoplastic cells had infiltrated the dermis and subcutaneous region surrounding sweat glands and nerves. All of the cases tested positive for CD8, other T cells, cytotoxic markers and EBV-encoded RNA (EBER) without CD56 expression. Molecular analysis was performed in three cases. All of the three analyses showed a TCRγ rearrangement and one case also had an IGH rearrangement. One of the patients with systemic EBV positive T-cell LPD of childhood experienced rapid evolved and died within five months of onset. CAEBV, systemic EBV-positive T-cell LPD of childhood and HVLL are distinct but overlapping diseases within the category of EBV-positive T-cell LPD of childhood. They constitute a continuous spectrum of EBV-infected associated disorders. PMID:25197370
Effect of screw fixation on acetabular component alignment change in total hip arthroplasty.
Fujishiro, Takaaki; Hayashi, Shinya; Kanzaki, Noriyuki; Hashimoto, Shingo; Shibanuma, Nao; Kurosaka, Masahiro
2014-06-01
The use of screws can enhance immediate cup fixation, but the influence of screw insertion on cup position has not previously been measured. The purpose of this study was to quantitatively evaluate the effect of intra-operative screw fixation on acetabular component alignment that has been inserted with the use of a navigation system. We used a navigation system to measure cup alignment at the time of press-fit and after screw fixation in 144 hips undergoing total hip arthroplasty. We also compared those findings with factors measured from postoperative radiographs. The mean intra-operative change of cup position was 1.78° for inclination and 1.81° for anteversion. The intra-operative change of anteversion correlated with the number of screws. The intra-operative change of inclination also correlated with medial hip centre. The insertion of screws can induce changes in cup alignment, especially when multiple screws are used or if a more medial hip centre is required for rigid acetabular fixation.
Anesthetic management of the SRS™ Endoscopic Stapling System for gastro-esophageal reflux disease.
Topuz, Ufuk; Umutoglu, Tarik; Bakan, Mefkur; Ozturk, Erdogan
2013-01-14
The SRS(TM) Endoscopic Stapling System (Medigus, Tel Aviv, Israel) is a new tool capable of creating a totally endoscopic fundoplication, combined with an endoscope, endoscopic ultrasound and a surgical stapler. SRS(TM) endoscopic stapling for gastro-esophageal reflux disease is a minimally invasive, outpatient procedure, which requires general anesthesia with positive-pressure ventilation. Keeping the patient on positive end-expiratory pressure (PEEP) may minimize the pressure gradient between the esophagus and the mediastinum, as well as help to prevent air from leaking around the screws and causing pneumomediastinum. In addition, in patients with hiatal hernia, higher PEEP levels may be required to increase intra-thoracic pressure and to force the stomach to slide into the abdomen for ease of endoscopy. We advise smoother emergence from anesthesia, taking precautions for retching, postoperative nausea and vomiting (PONV), while coughing and gagging during extubation and PONV may affect the success of the procedure. Total intravenous anesthesia with propofol and remifentanil seems to be a good choice for these reasons.
Current concepts and future perspectives in computer-assisted navigated total knee replacement.
Matsumoto, Tomoyuki; Nakano, Naoki; Lawrence, John E; Khanduja, Vikas
2018-05-12
Total knee replacements (TKR) aim to restore stability of the tibiofemoral and patella-femoral joints and provide relief of pain and improved quality of life for the patient. In recent years, computer-assisted navigation systems have been developed with the aim of reducing human error in joint alignment and improving patient outcomes. We examined the current body of evidence surrounding the use of navigation systems and discussed their current and future role in TKR. The current body of evidence shows that the use of computer navigation systems for TKR significantly reduces outliers in the mechanical axis and coronal prosthetic position. Also, navigation systems offer an objective assessment of soft tissue balancing that had previously not been available. Although these benefits represent a technical superiority to conventional TKR techniques, there is limited evidence to show long-term clinical benefit with the use of navigation systems, with only a small number of studies showing improvement in outcome scores at short-term follow-up. Because of the increased costs and operative time associated with their use as well as the emergence of more affordable and patient-specific technologies, it is unlikely for navigation systems to become more widely used in the near future. Whilst this technology helps surgeons to achieve improved component positioning, it is important to consider the clinical and functional implications, as well as the added costs and potential learning curve associated with adopting new technology.
Barker, Z E; Vázquez Diosdado, J A; Codling, E A; Bell, N J; Hodges, H R; Croft, D P; Amory, J R
2018-04-25
Time constraints for dairy farmers are an important factor contributing to the under-detection of lameness, resulting in delayed or missed treatment of lame cows within many commercial dairy herds. Hence, a need exists for flexible and affordable cow-based sensor systems capable of monitoring behaviors such as time spent feeding, which may be affected by the onset of lameness. In this study a novel neck-mounted mobile sensor system that combines local positioning and activity (acceleration) was tested and validated on a commercial UK dairy farm. Position and activity data were collected over 5 consecutive days for 19 high-yield dairy cows (10 lame, 9 nonlame) that formed a subset of a larger (120 cow) management group housed in a freestall barn. A decision tree algorithm that included sensor-recorded position and accelerometer data was developed to classify a cow as doing 1 of 3 categories of behavior: (1) feeding, (2) not feeding, and (3) out of pen for milking. For each classified behavior the mean number of bouts, the mean bout duration, and the mean total duration across all bouts was determined on a daily basis, and also separately for the time periods in between milking (morning = 0630-1300 h; afternoon = 1430-2100 h; night = 2230-0500 h). A comparative analysis of the classified cow behaviors was undertaken using a Welch t-test with Benjamini-Hochberg post-hoc correction under the null hypothesis of no differences in the number or duration of behavioral bouts between the 2 test groups of lame and nonlame cows. Analysis showed that mean total daily feeding duration was significantly lower for lame cows compared with non-lame cows. Behavior was also affected by time of day with significantly lower mean total duration of feeding and higher total duration of nonfeeding in the afternoons for lame cows compared with nonlame cows. The results demonstrate how sensors that measure both position and acceleration are capable of detecting differences in feeding behavior that may be associated with lameness. Such behavioral differences could be used in the development of predictive algorithms for the prompt detection of lameness as part of a commercially viable automated behavioral monitoring system. The Authors. Published by FASS Inc. and Elsevier Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roper, V.P.; Kobayashi, R.
1988-02-01
Infinite-dilution fugacity coefficients were obtained for the system fluorene/phenanthrene at thirteen temperatures by fitting total pressure across the entire mole fraction range by a computer routine. A thermodynamically consistent routine, that allowed for both positive and negative pressure deviations from the ideal values, was used to correlate data over the full mole fraction range from 0 to 1. The four-suffix Margules activity coefficient model without modification essentially served this purpose since total pressures and total pressure derivatives with respect to mole fraction were negligible compared to pressure measurement precision. The water/ethanol system and binary systems comprised of aniline, chlorobenzene, acetonitrilemore » and other polar compounds were fit for total pressure across the entire mole fraction range for binary Vapor-Liquid-Equilbria (VLE) using the rigorous, thermodynamically consistent Gibbs-Duhem Relation derived by Ibl and Dodge. Data correlation was performed using a computer least squares procedure. Infinite-dilution fugacity coefficients were obtained using a modified Margules activity coefficient model.« less
Three axis velocity probe system
Fasching, George E.; Smith, Jr., Nelson S.; Utt, Carroll E.
1992-01-01
A three-axis velocity probe system for determining three-axis positional velocities of small particles in fluidized bed systems and similar applications. This system has a sensor head containing four closely-spaced sensing electrodes of small wires that have flat ends to establish a two axis plane, e.g. a X-Y plane. Two of the sensing electrodes are positioned along one of the axes and the other two are along the second axis. These four sensing electrodes are surrounded by a guard electrode, and the outer surface is a ground electrode and support member for the sensing head. The electrodes are excited by, for example, sinusoidal voltage having a peak-to-peak voltage of up to 500 volts at a frequency of 2 MHz. Capacitive currents flowing between the four sensing electrodes and the ground electrode are influenced by the presence and position of a particle passing the sensing head. Any changes in these currents due to the particle are amplified and synchronously detected to produce positional signal values that are converted to digital form. Using these digital forms and two values of time permit generation of values of the three components of the particle vector and thus the total velocity vector.
Relationship between spirituality/religiousness and coping in patients with residual schizophrenia.
Shah, Ruchita; Kulhara, Parmanand; Grover, Sandeep; Kumar, Suresh; Malhotra, Rama; Tyagi, Shikha
2011-09-01
To measure spirituality/religiousness and its relation to coping skills in patients with residual schizophrenia. Using a cross-sectional design, 103 persons with residual schizophrenia were assessed on Positive and Negative Syndrome Scale [PANSS] and Ways of Coping Checklist [WCC] to assess the repertoire of coping skills and WHO Quality of Life-Spirituality, Religiousness and Personal Belief scale [WHOQOL-SRPB] to assess religiousness and spirituality. Positive reappraisal as a coping strategy had significant positive correlation with all the facets of WHOQOL-SRPB and SRPB total domain scores. The coping subscales of accepting responsibility, planful problem solving, distancing, confrontive coping, and self-controlling also had significant positive correlations with different facets of WHOQOL-SRPB and total SRPB domain score. Seeking social support and escape-avoidance as coping mechanisms had no correlations with any of the WHOQOL-SRPB facets. A sound spiritual, religious, or personal belief system is associated with active and adaptive coping skills in subjects with residual schizophrenia. Understanding and assessing the spirituality and religiousness of subjects with schizophrenia can help in better management of the disorder.
Adding a vocational focus to mental health rehabilitation.
Blankertz, L; Robinson, S
1996-11-01
The study examined the effect of adding two employment specialists to the staff of a community mental health center; their sole responsibility was to develop the skills and positive work attitudes that clients with severe mental illness need to enter the state vocational rehabilitation system or to seek employment. A total of 122 clients were randomly assigned to a program with an employment specialist or to a control group with no specialized vocational services. Clients in the program were taught work skills and attitudes in group and individual sessions and through a trial work experience. A schedule of rewards reinforced positive changes. Outcomes measured were skill gains, changes in work attitudes, attainment of employment, and entry into the state vocational rehabilitation system. At nine months, 34 of the 61 clients in the program achieved positive changes in vocational status that included competitive employment, participation in training and evaluation programs operated by the state vocational system, and formal referral to the system. Only one client in the control group was linked to the state system. Skill gains and positive changes in work attitudes were found for all program clients. Logistical regression suggested that program participation, rather than client characteristics, was an important predictor of a positive outcome. Over a relatively short time period, targeted vocational programs can help clients with severe mental illness develop the skills and attitudes necessary to attain employment or entry into the vocational rehabilitation system. Vocational rehabilitation can be an integral part of the rehabilitation process for all mental health clients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Anthony; Ravi, Ananth
2014-08-15
High dose rate (HDR) remote afterloading brachytherapy involves sending a small, high-activity radioactive source attached to a cable to different positions within a hollow applicator implanted in the patient. It is critical that the source position within the applicator and the dwell time of the source are accurate. Daily quality assurance (QA) tests of the positional and dwell time accuracy are essential to ensure that the accuracy of the remote afterloader is not compromised prior to patient treatment. Our centre has developed an automated, video-based QA system for HDR brachytherapy that is dramatically superior to existing diode or film QAmore » solutions in terms of cost, objectivity, positional accuracy, with additional functionalities such as being able to determine source dwell time and transit time of the source. In our system, a video is taken of the brachytherapy source as it is sent out through a position check ruler, with the source visible through a clear window. Using a proprietary image analysis algorithm, the source position is determined with respect to time as it moves to different positions along the check ruler. The total material cost of the video-based system was under $20, consisting of a commercial webcam and adjustable stand. The accuracy of the position measurement is ±0.2 mm, and the time resolution is 30 msec. Additionally, our system is capable of robustly verifying the source transit time and velocity (a test required by the AAPM and CPQR recommendations), which is currently difficult to perform accurately.« less
Pilon, C; Moore, P A; Pote, D H; Martin, J W; DeLaune, P B
2017-03-01
Metal runoff from fields fertilized with poultry litter may pose a threat to aquatic systems. Buffer strips located adjacent to fields may reduce nutrients and solids in runoff. However, scant information exists on the long-term effects of buffer strips combined with grazing management on metal runoff from pastures. The objective of this study was to assess the 12-yr impact of grazing management and buffer strips on metal runoff from pastures receiving poultry litter. The research was conducted using 15 watersheds (25 m wide and 57 m long) with five treatments: hayed (H), continuously grazed (CG), rotationally grazed (R), rotationally grazed with a buffer strip (RB), and rotationally grazed with a fenced riparian buffer strip (RBR). Poultry litter was applied annually in spring at 5.6 Mg ha. Runoff samples were collected after every rainfall event. Aluminum (Al) and iron (Fe) concentrations were strongly and positively correlated with total suspended solids, indicating soil erosion was the primary source. Soluble Al and Fe were not related to total Al and Fe. However, there was a strong positive correlation between soluble and total copper (Cu) concentrations. The majority of total Cu and zinc was in water-soluble form. The CG treatment had the highest metal concentrations and loads of all treatments. The RBR and H treatments resulted in lower concentrations of total Al, Cu, Fe, potassium, manganese, and total organic carbon in the runoff. Rotational grazing with a fenced riparian buffer and converting pastures to hayfields appear to be effective management systems for decreasing concentrations and loads of metals in surface runoff from pastures fertilized with poultry litter. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
2013-10-18
of the enclosed tasks plus the last parallel task for a total of five parallel tasks for one iteration, i). for j = 1…N for i = 1… 8 Figure...drizzling juices culminating in a state of salivating desire to cut a piece and enjoy. On the other hand, the smell could be that of a pungent, unpleasant
Longnecker, K.; Sherr, B. F.; Sherr, E. B.
2005-01-01
We evaluated whether bacteria with higher cell-specific nucleic acid content (HNA) or an active electron transport system, i.e., positive for reduction of 5-cyano-2,3-ditolyl tetrazolium chloride (CTC), were responsible for the bulk of bacterioplankton metabolic activity. We also examined whether the phylogenetic diversity of HNA and CTC-positive cells differed from the diversity of Bacteria with low nucleic acid content (LNA). Bacterial assemblages were sampled both in eutrophic shelf waters and in mesotrophic offshore waters in the Oregon coastal upwelling region. Cytometrically sorted HNA, LNA, and CTC-positive cells were assayed for their cell-specific [3H]leucine incorporation rates. Phylogenetic diversity in sorted non-radioactively labeled samples was assayed using denaturing gradient gel electrophoresis (DGGE) of PCR-amplified 16S rRNA genes. Cell-specific rates of leucine incorporation of HNA and CTC-positive cells were on average only slightly greater than the cell-specific rates of LNA cells. HNA cells accounted for most bacterioplankton substrate incorporation due to high abundances, while the low abundances of CTC-positive cells resulted in only a small contribution by these cells to total bacterial activity. The proportion of the total bacterial leucine incorporation attributable to LNA cells was higher in offshore regions than in shelf waters. Sequence data obtained from DGGE bands showed broadly similar phylogenetic diversity across HNA, LNA, and CTC-positive cells, with between-sample and between-region variability in the distribution of phylotypes. Our results suggest that LNA bacteria are not substantially different from HNA bacteria in either cell-specific rates of substrate incorporation or phylogenetic composition and that they can be significant contributors to bacterial metabolism in the sea. PMID:16332746
Longnecker, K; Sherr, B F; Sherr, E B
2005-12-01
We evaluated whether bacteria with higher cell-specific nucleic acid content (HNA) or an active electron transport system, i.e., positive for reduction of 5-cyano-2,3-ditolyl tetrazolium chloride (CTC), were responsible for the bulk of bacterioplankton metabolic activity. We also examined whether the phylogenetic diversity of HNA and CTC-positive cells differed from the diversity of Bacteria with low nucleic acid content (LNA). Bacterial assemblages were sampled both in eutrophic shelf waters and in mesotrophic offshore waters in the Oregon coastal upwelling region. Cytometrically sorted HNA, LNA, and CTC-positive cells were assayed for their cell-specific [3H]leucine incorporation rates. Phylogenetic diversity in sorted non-radioactively labeled samples was assayed using denaturing gradient gel electrophoresis (DGGE) of PCR-amplified 16S rRNA genes. Cell-specific rates of leucine incorporation of HNA and CTC-positive cells were on average only slightly greater than the cell-specific rates of LNA cells. HNA cells accounted for most bacterioplankton substrate incorporation due to high abundances, while the low abundances of CTC-positive cells resulted in only a small contribution by these cells to total bacterial activity. The proportion of the total bacterial leucine incorporation attributable to LNA cells was higher in offshore regions than in shelf waters. Sequence data obtained from DGGE bands showed broadly similar phylogenetic diversity across HNA, LNA, and CTC-positive cells, with between-sample and between-region variability in the distribution of phylotypes. Our results suggest that LNA bacteria are not substantially different from HNA bacteria in either cell-specific rates of substrate incorporation or phylogenetic composition and that they can be significant contributors to bacterial metabolism in the sea.
Francy, Donna S.; Bushon, Rebecca N.; Stopar, Julie; Luzano, Emma J.; Fout, G. Shay
2004-01-01
A study of small public ground-water-supply wells that produce water from discontinuous sand and gravel aquifers was done from July 1999 through July 2001 in southeastern Michigan. Samples were collected to determine the occurrence of viral pathogens and microbiological indicators of fecal contamination (indicators), determine whether indicators are adequate predictors of the presence of enteric viruses, and determine the factors that affect the presence of enteric viruses. Small systems are those that serve less than 3,300 people. Samples were analyzed for specific enteric viruses by reverse transcriptase-polymerase chain reaction (RT-PCR), for culturable viruses by cell culture, and for the indicators total coliforms, Escherichia coli (E. coli), enterococci, and F-specific and somatic coliphage. Ancillary environmental and water-quality data were collected or compiled. A total of 169 regular samples and 32 replicate pairs were collected from 38 wells. Replicate pairs were samples collected at the same well on the same date. One well was sampled 6 times, 30 wells were sampled five times, 6 wells were sampled twice, and 1 well was sampled once. By use of RT-PCR, enterovirus was found in four wells (10.5 percent) and hepatitis A virus (HAV) in five wells (13.2 percent). In two of these wells, investigators found both enterovirus and HAV, but on different sampling dates. Culturable viruses were found one time in two wells (5.9 percent), and neither of these wells was positive for viruses by use of RT-PCR on any sampling date. If results for all viruses are combined, 9 of the 38 small public-supply wells were positive for enteric viruses (23.7 percent) by either cell culture or RT-PCR. One or more indicators were found in 18 of 38 wells. Total coliforms, E. coli, enterococci, and F-specific and somatic coliphage were found in 34.2, 10.5, 15.8, 5.9, and 5.9 percent, respectively, of the wells tested. In only 3 out of 18 wells were samples positive for an indicator on more than one date at the same well. The co-occurrence of enteric viruses and any indicator was 55.6 percent; five out of the nine virus-positive wells were also found to be positive for an indicator. Two wells with detections of viruses had a detection of total coliforms, one well had a detection of E. coli, one of enterococci, and one of F-specific coliphage. On a per sample basis, of 11 samples that were positive for enteric viruses, indicator bacteria co-occurred in only 2 samples, and coliphage were not present in any. More virus-positive samples were found at sites served by septic systems than those served by sewerlines. Sampling condition (ground water or a mixture of tank and ground water), distance to septic system, type of and distance to nearest surface-water body, well characteristics, or land use were not related to the presence of viruses or indicators. Among continuous water-quality variables, statistically significant relations were found between total coliforms and dissolved organic carbon and between total coliforms and iron. There was a statistically significant relation between chloride concentrations >20 mg/L and detections of total coliforms. Presence of nitrate and nitrite was related to the presence of other indicators (E. coli, enterococci, and F-specific and somatic coliphage) or enteric viruses, but not to total coliforms. The data indicated that chloride-to-bromide (C1:Br) ratios may be useful as a screening tool for total coliforms and enteric viruses but not for E. coli, enterococci, and F-specific and somatic coliphage. This study provides evidence for fecal contamination of ground water from small public-supply wells, at least on an intermittent basis. Collecting data on multiple lines of evidence would be needed to reliably predict the presence of enteric viruses and protect public health. Future data collection toward this end could include repeat sampling several times a year for different indicators, measuring dissolv
Diversity of key players in the microbial ecosystems of the human body
Jordán, Ferenc; Lauria, Mario; Scotti, Marco; Nguyen, Thanh-Phuong; Praveen, Paurush; Morine, Melissa; Priami, Corrado
2015-01-01
Coexisting bacteria form various microbial communities in human body parts. In these ecosystems they interact in various ways and the properties of the interaction network can be related to the stability and functional diversity of the local bacterial community. In this study, we analyze the interaction network among bacterial OTUs in 11 locations of the human body. These belong to two major groups. One is the digestive system and the other is the female genital tract. In each local ecosystem we determine the key species, both the ones being in key positions in the interaction network and the ones that dominate by frequency. Beyond identifying the key players and discussing their biological relevance, we also quantify and compare the properties of the 11 networks. The interaction networks of the female genital system and the digestive system show totally different architecture. Both the topological properties and the identity of the key groups differ. Key groups represent four phyla of prokaryotes. Some groups appear in key positions in several locations, while others are assigned only to a single body part. The key groups of the digestive and the genital tracts are totally different. PMID:26514870
Diversity of key players in the microbial ecosystems of the human body.
Jordán, Ferenc; Lauria, Mario; Scotti, Marco; Nguyen, Thanh-Phuong; Praveen, Paurush; Morine, Melissa; Priami, Corrado
2015-10-30
Coexisting bacteria form various microbial communities in human body parts. In these ecosystems they interact in various ways and the properties of the interaction network can be related to the stability and functional diversity of the local bacterial community. In this study, we analyze the interaction network among bacterial OTUs in 11 locations of the human body. These belong to two major groups. One is the digestive system and the other is the female genital tract. In each local ecosystem we determine the key species, both the ones being in key positions in the interaction network and the ones that dominate by frequency. Beyond identifying the key players and discussing their biological relevance, we also quantify and compare the properties of the 11 networks. The interaction networks of the female genital system and the digestive system show totally different architecture. Both the topological properties and the identity of the key groups differ. Key groups represent four phyla of prokaryotes. Some groups appear in key positions in several locations, while others are assigned only to a single body part. The key groups of the digestive and the genital tracts are totally different.
Five-DOF innovative linear MagLev slider to account for pitch, tilt and load uncertainty
NASA Astrophysics Data System (ADS)
Kao, Yi-Ming; Tsai, Nan-Chyuan; Chiu, Hsin-Lin
2017-02-01
This paper is focused at position deviation regulation upon a slider by Fuzzy Sliding Mode Control (FSMC). Five Degrees Of Freedom (DOF) of position deviation are required to be regulated except for the direction (i.e., X-axis) in which the slider moves forward and backward. Totally 8 sets of Magnetic Actuators (MAs) and an Electro-Pneumatic Transducer (EPT) are employed to drive the slider carrying loads under the commands of FSMC. EPT is applied to adjust the pressure of compressed air to counterbalance the weight of slider itself. At first, the system dynamic model of slider, including load uncertainty and load position uncertainty, is established. Intensive computer simulations are undertaken to verify the validity of proposed control strategy. Finally, a prototype of realistic slider position deviation regulation system is successfully built up. According to the experiments by cooperation of pneumatic and magnetic control, the actual linear position deviations of slider can be regulated within ±8 μm and angular position deviations within ±1 mini-degrees. From the viewpoint of energy consumption, the applied currents to 8 sets of MAs are all below 1.2 A. To sum up, the closed-loop levitation system by cooperation of pneumatic and magnetic control is capable to account for load uncertainty and uncertainty of the standing position of load to be carried.
Hospital financial position and the adoption of electronic health records.
Ginn, Gregory O; Shen, Jay J; Moseley, Charles B
2011-01-01
The objective of this study was to examine the relationship between financial position and adoption of electronic health records (EHRs) in 2442 acute care hospitals. The study was cross-sectional and utilized a general linear mixed model with the multinomial distribution specification for data analysis. We verified the results by also running a multinomial logistic regression model. To measure our variables, we used data from (1) the 2007 American Hospital Association (AHA) electronic health record implementation survey, (2) the 2006 Centers for Medicare and Medicaid Cost Reports, and (3) the 2006 AHA Annual Survey containing organizational and operational data. Our dependent variable was an ordinal variable with three levels used to indicate the extent of EHR adoption by hospitals. Our independent variables were five financial ratios: (1) net days revenue in accounts receivable, (2) total margin, (3) the equity multiplier, (4) total asset turnover, and (5) the ratio of total payroll to total expenses. For control variables, we used (1) bed size, (2) ownership type, (3) teaching affiliation, (4) system membership, (5) network participation, (6) fulltime equivalent nurses per adjusted average daily census, (7) average daily census per staffed bed, (8) Medicare patients percentage, (9) Medicaid patients percentage, (10) capitation-based reimbursement, and (11) nonconcentrated market. Only liquidity was significant and positively associated with EHR adoption. Asset turnover ratio was significant but, unexpectedly, was negatively associated with EHR adoption. However, many control variables, most notably bed size, showed significant positive associations with EHR adoption. Thus, it seems that hospitals adopt EHRs as a strategic move to better align themselves with their environment.
Hu, Jianping; Zhen, Shuangju; Yu, Chengfu; Zhang, Qiuyan; Zhang, Wei
2017-01-01
Based on the Dual Systems Model (Somerville et al., 2010; Steinberg, 2010a) and the biosocial-affect model (Romer and Hennessy, 2007) of adolescent sensation seeking and problem behaviors, the present study examined how (affective associations with online games as a mediator) and when (impulsivity as a moderator) did sensation seeking influence online gaming addiction in adolescence. A total of 375 Chinese male adolescents (mean age = 16.02 years, SD = 0.85) from southern China completed anonymous questionnaires regarding sensation seeking, positive affective associations with online games, impulsivity, and online gaming addiction. Our findings revealed that sensation seeking, positive affective associations with online games and impulsivity were each significantly and positively associated with online gaming addiction in adolescents. Positive affective associations mediated the relationship between sensation seeking and online gaming addiction. Further, impulsivity moderated the relationship between positive affective associations and online gaming addiction, such that the association between positive affective association and online gaming addiction was stronger for high than for low impulsivity adolescents. These findings underscore the importance of integrating the biosocial-affect model and the Dual Systems Model to understand how and when sensation seeking impacts adolescent online gaming addiction.
Hu, Jianping; Zhen, Shuangju; Yu, Chengfu; Zhang, Qiuyan; Zhang, Wei
2017-01-01
Based on the Dual Systems Model (Somerville et al., 2010; Steinberg, 2010a) and the biosocial-affect model (Romer and Hennessy, 2007) of adolescent sensation seeking and problem behaviors, the present study examined how (affective associations with online games as a mediator) and when (impulsivity as a moderator) did sensation seeking influence online gaming addiction in adolescence. A total of 375 Chinese male adolescents (mean age = 16.02 years, SD = 0.85) from southern China completed anonymous questionnaires regarding sensation seeking, positive affective associations with online games, impulsivity, and online gaming addiction. Our findings revealed that sensation seeking, positive affective associations with online games and impulsivity were each significantly and positively associated with online gaming addiction in adolescents. Positive affective associations mediated the relationship between sensation seeking and online gaming addiction. Further, impulsivity moderated the relationship between positive affective associations and online gaming addiction, such that the association between positive affective association and online gaming addiction was stronger for high than for low impulsivity adolescents. These findings underscore the importance of integrating the biosocial-affect model and the Dual Systems Model to understand how and when sensation seeking impacts adolescent online gaming addiction. PMID:28529494
Match Physical Performance of Elite Female Soccer Players During International Competition.
Datson, Naomi; Drust, Barry; Weston, Matthew; Jarman, Ian H; Lisboa, Paulo J; Gregson, Warren
2017-09-01
Datson, N, Drust, B, Weston, M, Jarman, IH, Lisboa, P, and Gregson, W. Match physical performance of elite female soccer players during international competition. J Strength Cond Res 31(9): 2379-2387, 2017-The purpose of this study was to provide a detailed analysis of the physical demands of competitive international female soccer match play. A total of 148 individual match observations were undertaken on 107 outfield players competing in competitive international matches during the 2011-2012 and 2012-2013 seasons, using a computerized tracking system (Prozone Sports Ltd., Leeds, England). Total distance and total high-speed running distances were influenced by playing position, with central midfielders completing the highest (10,985 ± 706 m and 2,882 ± 500 m) and central defenders the lowest (9,489 ± 562 m and 1,901 ± 268 m) distances, respectively. Greater total very high-speed running distances were completed when a team was without (399 ± 143 m) compared to with (313 ± 210 m) possession of the ball. Most sprints were over short distances with 76% and 95% being less than 5 and 10 m, respectively. Between half reductions in physical performance were present for all variables, independent of playing position. This study provides novel findings regarding the physical demands of different playing positions in competitive international female match play and provides important insights for physical coaches preparing elite female players for competition.
Role of the Hospital Library Within the Hospital System *†
Lorenzi, Nancy M.
1969-01-01
The results of a survey of hospital administrators, attending staff and house staff physicians, librarians, library committee chairmen, and nursing staff in five Northeastern Ohio hospitals concerning the status of the hospital library within the total hospital system are related. Results indicate that hospital libraries operate in the “fringe” area of the hospital system. A concentric-circle figure indicates the present position of the majority of hospital libraries surveyed. The future relationship of the library within the hospital system has also been represented by a concentric-circle figure. PMID:5778727
Ramos, Guilherme P; Nakamura, Fábio Y; Penna, Eduardo M; Wilke, Carolina Franco; Pereira, Lucas A; Loturco, Irineu; Capelli, Luciano; Mahseredjian, Fábio; Silami-Garcia, Emerson; Coimbra, Cândido C
2017-07-31
The aim of this study was to compare locomotor activity profiles of Brazilian top-class female soccer players competing at distinct age brackets (U17, U20, and Senior). External match load of 14 U17, 14 U20, and 17 Senior female soccer players competing in 6-7 full official international matches were assessed using global positioning systems (GPS). Total distance covered, distance covered in high intensity (HID:15.6-20 kmh), distance covered in sprints (sprint:>20 kmh), number of accelerations (Acc)>1 ms, decelerations (Dec) >-1 ms, and Player Load generally increased across the age brackets (U17
RHIC BPM SYSTEM MODIFICATIONS AND PERFORMANCE.
DOE Office of Scientific and Technical Information (OSTI.GOV)
SATOGATA, T.; CALAGA, R.; CAMERON, P.
2005-05-16
The RHIC beam position monitor (BPM) system provides independent average orbit and turn-by-turn (TBT) position measurements. In each ring, there are 162 measurement locations per plane (horizontal and vertical) for a total of 648 BPM planes in the RHIC machine. During 2003 and 2004 shutdowns, BPM processing electronics were moved from the RHIC tunnel to controls alcoves to reduce radiation impact, and the analog signal paths of several dozen modules were modified to eliminate gain-switching relays and improve signal stability. This paper presents results of improved system performance, including stability for interaction region beam-based alignment efforts. We also summarize performancemore » of recently-added DSP profile scan capability, and improved million-turn TBT acquisition channels for 10 Hz triplet vibration, nonlinear dynamics, and echo studies.« less
Jeong, Seri; Yang, Heeyoung; Hwang, Hyunyong
2017-01-01
This study aimed to evaluate the diagnostic utilities of the automated connective tissues disease screening assay, CTD screen, in patients with systemic rheumatic diseases. A total of 1093 serum samples were assayed using CTD screen and indirect immunofluorescent (IIF) methods. Among them, 162 were diagnosed with systemic rheumatic disease, including rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), and mixed connective tissue disease (MCT). The remaining 931 with non-systemic rheumatic disease were assigned to the control group. The median ratios of CTD screen tests were significantly higher in the systemic rheumatic disease group than in the control group. The positive likelihood ratios of the CTD screen were higher than those of IIF in patients with total rheumatic diseases (4.1 vs. 1.6), including SLE (24.3 vs. 10.7). The areas under the receiver operating characteristic curves (ROC-AUCs) of the CTD screen for discriminating total rheumatic diseases, RA, SLE, and MCT from controls were 0.68, 0.56, 0.92 and 0.80, respectively. The ROC-AUCs of the combinations with IIF were significantly higher in patients with total rheumatic diseases (0.72) and MCT (0.85) than in those of the CTD screen alone. Multivariate analysis indicated that both the CTD screen and IIF were independent variables for predicting systemic rheumatic disease. CTD screen alone and in combination with IIF were a valuable diagnostic tool for predicting systemic rheumatic diseases, particularly for SLE. PMID:28273146
Jeong, Seri; Yang, Heeyoung; Hwang, Hyunyong
2017-01-01
This study aimed to evaluate the diagnostic utilities of the automated connective tissues disease screening assay, CTD screen, in patients with systemic rheumatic diseases. A total of 1093 serum samples were assayed using CTD screen and indirect immunofluorescent (IIF) methods. Among them, 162 were diagnosed with systemic rheumatic disease, including rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), and mixed connective tissue disease (MCT). The remaining 931 with non-systemic rheumatic disease were assigned to the control group. The median ratios of CTD screen tests were significantly higher in the systemic rheumatic disease group than in the control group. The positive likelihood ratios of the CTD screen were higher than those of IIF in patients with total rheumatic diseases (4.1 vs. 1.6), including SLE (24.3 vs. 10.7). The areas under the receiver operating characteristic curves (ROC-AUCs) of the CTD screen for discriminating total rheumatic diseases, RA, SLE, and MCT from controls were 0.68, 0.56, 0.92 and 0.80, respectively. The ROC-AUCs of the combinations with IIF were significantly higher in patients with total rheumatic diseases (0.72) and MCT (0.85) than in those of the CTD screen alone. Multivariate analysis indicated that both the CTD screen and IIF were independent variables for predicting systemic rheumatic disease. CTD screen alone and in combination with IIF were a valuable diagnostic tool for predicting systemic rheumatic diseases, particularly for SLE.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Able, CM; Baydush, AH; Nguyen, C
Purpose: To determine the effectiveness of SPC analysis for a model predictive maintenance process that uses accelerator generated parameter and performance data contained in trajectory log files. Methods: Each trajectory file is decoded and a total of 131 axes positions are recorded (collimator jaw position, gantry angle, each MLC, etc.). This raw data is processed and either axis positions are extracted at critical points during the delivery or positional change over time is used to determine axis velocity. The focus of our analysis is the accuracy, reproducibility and fidelity of each axis. A reference positional trace of the gantry andmore » each MLC is used as a motion baseline for cross correlation (CC) analysis. A total of 494 parameters (482 MLC related) were analyzed using Individual and Moving Range (I/MR) charts. The chart limits were calculated using a hybrid technique that included the use of the standard 3σ limits and parameter/system specifications. Synthetic errors/changes were introduced to determine the initial effectiveness of I/MR charts in detecting relevant changes in operating parameters. The magnitude of the synthetic errors/changes was based on: TG-142 and published analysis of VMAT delivery accuracy. Results: All errors introduced were detected. Synthetic positional errors of 2mm for collimator jaw and MLC carriage exceeded the chart limits. Gantry speed and each MLC speed are analyzed at two different points in the delivery. Simulated Gantry speed error (0.2 deg/sec) and MLC speed error (0.1 cm/sec) exceeded the speed chart limits. Gantry position error of 0.2 deg was detected by the CC maximum value charts. The MLC position error of 0.1 cm was detected by the CC maximum value location charts for every MLC. Conclusion: SPC I/MR evaluation of trajectory log file parameters may be effective in providing an early warning of performance degradation or component failure for medical accelerator systems.« less
NASA Technical Reports Server (NTRS)
Quach, Cuong C.
2004-01-01
NASA/Langley Research Center collaborated with the Federal Aviation Administration (FAA) to test a Runway Incursion Prevention System (RIPS) at the Dallas Fort Worth International Airport (DFW) in October 2000. The RIPS combines airborne and ground sensor data with various cockpit displays to improve pilots' awareness of traffic conditions on the airport surface. The systems tested at DFW involved surface radar and data systems that gather and send surface traffic information to a research aircraft outfitted with the RIPS software, cockpit displays, and data link transceivers. The data sent to the airborne systems contained identification and GPS location of traffic. This information was compared with the own-ship location from airborne GPS receivers to generate incursion alerts. A total of 93 test tracks were flown while operating RIPS. This report compares the accuracy of the airborne GPS systems that gave the own-ship position of the research aircraft for the 93 test tracks.
Sasaki, Konosuke; Haga, Mayu; Endo, Yoichi; Fujiwara, Junko; Maruyama, Ryoko
2017-04-01
Some studies have reported that recumbent position may have advantages in patients with heart disease and in pregnancy. However, it remains controversial whether recumbent position affects autonomic nervous system activity and hemodynamics in healthy adults. The aim of this study was to evaluate alterations in heart rate variability (HRV) and hemodynamics in the supine, left recumbent and right recumbent positions in healthy young adults. A total of 80 participants aged 22.8 ± 3.1 years were enrolled in this observational study. Fifty-eight volunteers (29 men and 29 women) maintained the supine position followed by the left and right recumbent positions, while electrocardiographic data were recorded for spectral analysis of HRV to assess cardiac vagal nerve and sympathetic nerve activities. The heart rate (HR) was significantly lower in the left recumbent position than in the other positions. There were no statistically significant differences in HRV among the three positions. Considering the possibility that the echographic procedure affects autonomic nervous system (ANS) activity, the other 22 participants (11 men and 11 women) underwent an echographic evaluation of hemodynamics in the heart and inferior vena cava (IVC) across the three positions. Although a low HR was also observed, there were no statistically significant differences in the IVC or the heart blood volume between the supine and the left recumbent positions. A postural change to the left recumbent position does not affect the cardiac blood circulation or ANS activity, though it does decrease HR in healthy young adults. This finding indicates that the lower HR in the left recumbent position is not attributable to the ANS activity.
McCrorie, Paul R W; Fenton, Candida; Ellaway, Anne
2014-09-13
The environment has long been associated with physical activity engagement, and recent developments in technology have resulted in the ability to objectively quantify activity behaviours and activity context. This paper reviews studies that have combined Global Positioning Systems (GPS), Geographic Information Systems (GIS) and accelerometry to investigate the PA-environment relationship in children and young people (5-18 years old). Literature searches of the following bibliographic databases were undertaken: Sportdiscus, Medline, Embase, CINAHL, Psychinfo and Applied Social Sciences Index and Abstracts (ASSIA). Fourteen studies met the inclusion criteria, and covered topics including greenspace use, general land use, active travel, and the built environment. Studies were largely cross-sectional and took place across developed countries (UK, USA, Canada, New Zealand, and Australia). Findings suggest that roads and streets, school grounds, and the home location are important locations for total PA, and moderate to vigorous PA (MVPA). The relationship between greenspace was positive, however, multiple definitions and outcome measures add complexity to the results. MVPA was more likely in those exposed to higher levels of greenspace compared to sedentary individuals. Total MVPA time in greenspace is low, but when framed as a proportion of the total can be quite high. Domestic gardens may be an important area for higher intensity activity.
Data traffic reduction schemes for sparse Cholesky factorizations
NASA Technical Reports Server (NTRS)
Naik, Vijay K.; Patrick, Merrell L.
1988-01-01
Load distribution schemes are presented which minimize the total data traffic in the Cholesky factorization of dense and sparse, symmetric, positive definite matrices on multiprocessor systems with local and shared memory. The total data traffic in factoring an n x n sparse, symmetric, positive definite matrix representing an n-vertex regular 2-D grid graph using n (sup alpha), alpha is equal to or less than 1, processors are shown to be O(n(sup 1 + alpha/2)). It is O(n(sup 3/2)), when n (sup alpha), alpha is equal to or greater than 1, processors are used. Under the conditions of uniform load distribution, these results are shown to be asymptotically optimal. The schemes allow efficient use of up to O(n) processors before the total data traffic reaches the maximum value of O(n(sup 3/2)). The partitioning employed within the scheme, allows a better utilization of the data accessed from shared memory than those of previously published methods.
Time determination for spacecraft users of the Navstar Global Positioning System /GPS/
NASA Technical Reports Server (NTRS)
Grenchik, T. J.; Fang, B. T.
1977-01-01
Global Positioning System (GPS) navigation is performed by time measurements. A description is presented of a two body model of spacecraft motion. Orbit determination is the process of inferring the position, velocity, and clock offset of the user from measurements made of the user motion in the Newtonian coordinate system. To illustrate the effect of clock errors and the accuracy with which the user spacecraft time and orbit may be determined, a low-earth-orbit spacecraft (Seasat) as tracked by six Phase I GPS space vehicles is considered. The obtained results indicate that in the absence of unmodeled dynamic parameter errors clock biases may be determined to the nanosecond level. There is, however, a high correlation between the clock bias and the uncertainty in the gravitational parameter GM, i.e., the product of the universal gravitational constant and the total mass of the earth. It is, therefore, not possible to determine clock bias to better than 25 nanosecond accuracy in the presence of a gravitational error of one part per million.
NASA Astrophysics Data System (ADS)
Wang, Jianping; Zhang, Peiran; Lu, Huimin; Feng, LiFang
2017-06-01
An orthogonal frequency division multiplexing (OFDM) technique called flipped OFDM (flip-OFDM) is apposite for a visible light communication system that needs the transmitted signal to be real and positive. Flip-OFDM uses two consecutive OFDM subframes to transmit the positive and negative parts of the signal. However, peak-to-average power ratio (PAPR) for flip-OFDM is increased tremendously due to the low value of total average power that arises from many zero values in both the positive and flipped frames. We first analyze the performance of flip-OFDM and perform a comparison with the conventional DC-biased OFDM (DCO-OFDM); then we propose a flip-OFDM scheme combined with μ-law mapping to reduce the high PAPR. The simulation results show that the PAPR of the system is reduced about 17.2 and 5.9 dB when compared with the normal flip-OFDM and DCO-OFDM signals, respectively.
Problems with studying wolf predation on small prey in summer via global positioning system collars
Palacios, Vicente; Mech, L. David
2010-01-01
We attempted to study predation on various-sized prey by a male and female wolf (Canis lupus) with global positioning system (GPS) collars programmed to acquire locations every 10 min in the Superior National Forest of Minnesota. During May to August 2007, we investigated 147 clusters of locations (31% of the total) and found evidence of predation on a white-tailed deer (Odocoileus virginianus) fawn and yearling, a beaver (Castor canadensis), ruffed grouse (Bonasa umbellus), and fisher (Martes pennanti) and scavenging on a road-killed deer and other carrion. However, we missed finding many prey items and discuss the problems associated with trying to conduct such a study.
Problems with studying wolf predation on small prey in summer via global positioning system collars
Palacios, V.; Mech, L.D.
2011-01-01
We attempted to study predation on various-sized prey by a male and female wolf (Canis lupus) with global positioning system (GPS) collars programmed to acquire locations every 10 min in the Superior National Forest of Minnesota. During May to August 2007, we investigated 147 clusters of locations (31% of the total) and found evidence of predation on a white-tailed deer (Odocoileus virginianus) fawn and yearling, a beaver (Castor canadensis), ruffed grouse (Bonasa umbellus), and fisher (Martes pennanti) and scavenging on a road-killed deer and other carrion. However, we missed finding many prey items and discuss the problems associated with trying to conduct such a study. ?? 2010 US Government.
Chee, Y C
1983-01-01
'Total antinuclear antibody' (ANF) is detected by the fluorescent antinuclear antibody technique which is a screening test, positive in 99% of systemic lupus erythematosus (SLE) sera. The LE factor (positive in 75% of SLE sera), like the anti-DNA antibody, is an antinuclear antibody but directed against DNA-histone. ANF-negative SLE is a clinical entity with absence of these antibodies. A false negative ANF, in the presence of high titre anti-DNA antibody and/or LE cells, is illustrated in two cases of SLE. Postulated mechanisms for this phenomenon are interference in ANF detection by rheumatoid factor, and the prozone effect on the immunofluorescent tests.
[Characteristics of blood type irregular antibodies in Han population of Chinese Sichuan area].
Li, Cui-Ying; Li, Yun-Ming; Huang, Fei; Xiao, Jie; Xu, Hong
2015-04-01
To analyze the distribution of irregular antibody of red blood cells in Han population of Chinese Sichuan area, so as to provide valuable information for the safety of transfusion and decrease of immune hemolytic transfusion reaction. Blood samples from June 2006 to May 2013 were tested for irregular antibody screening and identification, calculating the composition rate, group characteristics and the positive detection rate of irregular antibody. A total of 36287 blood samples were tested, out of them 571 samples were the irregular antibody positive, the positive rate was 1.574%(571/36 287), specific alloantibodies were found in 312 samples, the positive rate was 0.860%(312/36287). And autoantibody was found in 259 samples, the positive rate was 0.714%(259/36 287). The specific alloantibodies ratio in Rh system was the highest, reaching to 73.72%(230/312) with the positive rate of 0.634%;36 cases in Lewis system, account for 11.54%(36/312) with the positive rate of 0.099%; 34 cases in MNS system account for 10.89%(34/312) with the positive rate of 0.094%; direct coomb test showed positive result in 284 samples, the rate was 0.78%. The detected rate of positive irregular antibody in female is obviously higher than that in male patients (P<0.001), and it is also higher in people with pregnancy or transfusion than that in those without it (P<0.05). The irregular antibody screening and identification are very important in blood transfusion, especially for female and people with transfusion or pregnant history.
[Sensitivity and antibiotic resistance in infections of the musculoskeletal system].
Mata-Hernández, Argenis; Rivera-Villa, Adrián Huematzin; Miguel-Pérez, Adrián; Pérez-Atanasio, José Manuel; Torres-González, Rubén
2016-01-01
Infections of the musculoskeletal system are a devastating complication for patients, due to it's long rehabilitation process and even sometimes the removal of the implant, the chronicity of infection, is often due to lack of coverage in empirical antibiotics. A retrospective, observational, descriptive cohort study was performed. All cultures form musculoskeletal system infected patients reported of sensitivity and resistance of germs isolated were analyzed. A total of 143 positive results were included. Reported more frequent germ Staphylococcus aureus accounted for 75 positive cases, followed by Escherichia coli with 31 positive results. Antibiotics with better sensitivity according to the type of microorganisms were trimethoprim-sulfamethoxazole and vancomycin, levofloxacin and linezolid, gentamicin, erythromycin and amikacin. Regarding antibiotic resistance, those reported with the highest percentage were penicillin G, amoxicillin with clavulanic acid and ampicillin. We recommend using empirical treatments in musculoskeletal system infections, trimethoprim-sulfamethoxazole are the best choice because they have the same sensitivity compare with vancomycin and a resistance rate of 7.6%. Betalactamics have a high percentage of resistance and low sensitivity so we must consider alternatives.
Aktaş, Osman; Aydin, Hakan; Uslu, Hakan
2016-02-17
Human parvovirus B19 is a pathogen that affects different parts of the body. We planned this study because of the lack of data on B19 seroprevalence based on different body-system diseases. The prevalence of parvovirus B19 antibodies was investigated retrospectively in 1239 patients by review of medical records from 2009-2012, according to their diseases classified under general titles in compliance with the International Classification of Diseases (ICD-10). Parvovirus B19-specific antibodies were detected by quantitative enzyme immunoassays. The positivity rate was 27.8% for only IgG, 8.5% for only IgM, and 2.6% for both IgG and IgM. The highest positivity for IgG alone was found in musculoskeletal system and connective tissue diseases (55.9%), while the highest positivity for IgM was found in neoplasms (16.4%). The highest positivity for IgG was seen in rheumatoid arthritis (72.2%) and pregnancy (52.6%), and the highest positivity for total IgM was found in upper respiratory tract disease (21.0%) and hepatic failure (17.1%). Parvovirus B19 seroprevalence was relatively low in northeastern Anatolia compared to most serological studies conducted in other regions. We think that this study has provided the first wide-ranging information on the seroprevalence of B19 in diseases and disorders of the major human body systems.
Dillon, Patrick A; Kempton, Thomas; Ryan, Samuel; Hocking, Joel; Coutts, Aaron J
2018-03-01
To examine the effects of match-related and individual player characteristics on activity profile and technical performance during rotations in professional Australian football. Longitudinal observational study. Global positioning system data and player rating scores were collected from 33 professional Australian football players during 15 Australian football League matches. Player rating scores were time aligned with their relative total and high-speed running (HSR) distance (>20kmh -1 ) for each on ground rotation. Individual players' maximal aerobic running speed (MAS) was determined from a two-kilometre trial. A multilevel linear mixed model was used to examine the influence of rotations on physical activity profiles and skill execution during match play. Rotation duration and accumulated distance resulted in a trivial-to-moderate reduction in relative total and HSR distances as well as relative rating points. The number of disposals in a rotation had a small positive effect on relative total and HSR distances and a large positive effect on relative rating points. MAS was associated with a moderate-to-large increase in relative total distance, but had a large negative effect on relative rating points. Previous rotation time, stoppages and the number of rotations in the quarter had a trivial-to-small negative effect on relative total and HSR distances. A greater speed (mmin -1 ) was associated with a trivial increase in rating points during a rotation, while there was a trivial decrease in relative total distance as rating points increased. The complex relationship between factors that influence activity profile and technical performance during rotations in Australian football needs to be considered when interpreting match performance. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Balance of Interactions Determines Optimal Survival in Multi-Species Communities.
Choudhary, Anshul; Sinha, Sudeshna
2015-01-01
We consider a multi-species community modelled as a complex network of populations, where the links are given by a random asymmetric connectivity matrix J, with fraction 1 - C of zero entries, where C reflects the over-all connectivity of the system. The non-zero elements of J are drawn from a Gaussian distribution with mean μ and standard deviation σ. The signs of the elements Jij reflect the nature of density-dependent interactions, such as predatory-prey, mutualism or competition, and their magnitudes reflect the strength of the interaction. In this study we try to uncover the broad features of the inter-species interactions that determine the global robustness of this network, as indicated by the average number of active nodes (i.e. non-extinct species) in the network, and the total population, reflecting the biomass yield. We find that the network transitions from a completely extinct system to one where all nodes are active, as the mean interaction strength goes from negative to positive, with the transition getting sharper for increasing C and decreasing σ. We also find that the total population, displays distinct non-monotonic scaling behaviour with respect to the product μC, implying that survival is dependent not merely on the number of links, but rather on the combination of the sparseness of the connectivity matrix and the net interaction strength. Interestingly, in an intermediate window of positive μC, the total population is maximal, indicating that too little or too much positive interactions is detrimental to survival. Rather, the total population levels are optimal when the network has intermediate net positive connection strengths. At the local level we observe marked qualitative changes in dynamical patterns, ranging from anti-phase clusters of period 2 cycles and chaotic bands, to fixed points, under the variation of mean μ of the interaction strengths. We also study the correlation between synchronization and survival, and find that synchronization does not necessarily lead to extinction. Lastly, we propose an effective low dimensional map to capture the behavior of the entire network, and this provides a broad understanding of the interplay of the local dynamical patterns and the global robustness trends in the network.
2011-09-01
PBL may see changes as the design is actually implemented . Such changes are typically for practical reasons of adapting to either specific...shall use a configuration management approach to establish and control product attributes and the product baseline across the total system life cycle... practice that helps prevent government interference in subcontracts, holds the prime contractor accountable for their end product (s), limits the potential
Effects of diffusion on total biomass in heterogeneous continuous and discrete-patch systems
DeAngelis, Donald L.; Ming Ni, Wei; Zhang, Bo
2016-01-01
Theoretical models of populations on a system of two connected patches previously have shown that when the two patches differ in maximum growth rate and carrying capacity, and in the limit of high diffusion, conditions exist for which the total population size at equilibrium exceeds that of the ideal free distribution, which predicts that the total population would equal the total carrying capacity of the two patches. However, this result has only been shown for the Pearl-Verhulst growth function on two patches and for a single-parameter growth function in continuous space. Here, we provide a general criterion for total population size to exceed total carrying capacity for three commonly used population growth rates for both heterogeneous continuous and multi-patch heterogeneous landscapes with high population diffusion. We show that a sufficient condition for this situation is that there is a convex positive relationship between the maximum growth rate and the parameter that, by itself or together with the maximum growth rate, determines the carrying capacity, as both vary across a spatial region. This relationship occurs in some biological populations, though not in others, so the result has ecological implications.
Lucke, Terry; Nichols, Peter W B
2015-12-01
This study evaluated the pollution removal and hydrologic performance of five, 10-year old street-side bioretention systems. The bioretention basins were subjected to a series of simulated rainfall events using synthetic stormwater. Four different pollution concentrations were tested on three of the bioretention basins. The four concentrations tested were: A) no pollution; B) typical Australian urban pollutant loads; C) double the typical pollution loads, and; D) five times the typical pollution loads. Tests were also undertaken to determine the levels of contaminant and heavy metals build-up that occurred in the filter media over the 10 year operational life of the bioretention systems. Although highly variable, the overall hydrological performance of the basins was found to be positive, with all basins attenuating flows, reducing both peak flow rates and total outflow volumes. Total suspended solids removal performance was variable for all tests and no correlation was found between performance and dosage. Total nitrogen (TN) removal was positive for Tests B, C and D. However, the TN removal results for Test A were found to be negative. Total phosphorus (TP) was the only pollutant to be effectively removed from all basins for all four synthetic stormwater tests. The study bioretention basins were found to export pollutants during tests where no pollutants were added to the simulated inflow water (Test A). Heavy metal and hydrocarbon testing undertaken on the bioretention systems found that the pollution levels of the filter media were still within acceptable limits after 10 years in operation. This field study has shown bioretention basin pollution removal performance to be highly variable and dependant on a range of factors including inflow pollution concentrations, filter media, construction methods and environmental factors. Further research is required in order to fully understand the potential stormwater management benefits of these systems. Copyright © 2015 Elsevier B.V. All rights reserved.
Future satellite systems - Market demand assessment
NASA Technical Reports Server (NTRS)
Reiner, P. S.
1981-01-01
During 1979-80, a market study was performed regarding the future total demand for communications services, and satellite transmission service at the 4/6 GHz, 12/14 GHz, and 20/30 GHz frequencies. Included in the study were a variety of communications traffic characteristics as well as projections of the cost of C and Ku band satellite systems through the year 2000. In connection with the considered study, a total of 15 major study tasks and subtasks were undertaken and were all interrelated in various ways. The telecommunications service forecasts were concerned with a total of 21 data services, 5 voice services, and 5 video services. The traffic volumes within the U.S. for the three basic services were projected for three time periods. It is found that the fixed frequency allocation for domestic satellites combined with potential interference from adjacent satellites means a near term lack of orbital positions above the U.S.
A Vibrating Wire System For Quadrupole Fiducialization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wolf, Zachary
2010-12-13
A vibrating wire system is being developed to fiducialize the quadrupoles between undulator segments in the LCLS. This note provides a detailed analysis of the system. The LCLS will have quadrupoles between the undulator segments to keep the electron beam focused. If the quadrupoles are not centered on the beam axis, the beam will receive transverse kicks, causing it to deviate from the undulator axis. Beam based alignment will be used to move the quadrupoles onto a straight line, but an initial, conventional alignment must place the quadrupole centers on a straight line to 100 {micro}m. In the fiducialization stepmore » of the initial alignment, the position of the center of the quadrupole is measured relative to tooling balls on the outside of the quadrupole. The alignment crews then use the tooling balls to place the magnet in the tunnel. The required error on the location of the quadrupole center relative to the tooling balls must be less than 25 {micro}m. In this note, we analyze a system under construction for the quadrupole fiducialization. The system uses the vibrating wire technique to position a wire onto the quadrupole magnetic axis. The wire position is then related to tooling balls using wire position detectors. The tooling balls on the wire position detectors are finally related to tooling balls on the quadrupole to perform the fiducialization. The total 25 {micro}m fiducialization error must be divided between these three steps. The wire must be positioned onto the quadrupole magnetic axis to within 10 {micro}m, the wire position must be measured relative to tooling balls on the wire position detectors to within 15 {micro}m, and tooling balls on the wire position detectors must be related to tooling balls on the quadrupole to within 10 {micro}m. The techniques used in these three steps will be discussed. The note begins by discussing various quadrupole fiducialization techniques used in the past and discusses why the vibrating wire technique is our method of choice. We then give an overview of the measurement system showing how the vibrating wire is positioned onto the quadrupole axis, how the wire position detectors locate the wire relative to tooling balls without touching the wire, and how the tooling ball positions are all measured. The novel feature of this system is the vibrating wire which we discuss in depth. We analyze the wire dynamics and calculate the expected sensitivity of the system. The note should be an aid in debugging the system by providing calculations to compare measurements to.« less
Identifying seedling root architectural traits associated with yield and yield components in wheat.
Xie, Quan; Fernando, Kurukulasuriya M C; Mayes, Sean; Sparkes, Debbie L
2017-05-01
Plant roots growing underground are critical for soil resource acquisition, anchorage and plant-environment interactions. In wheat ( Triticum aestivum ), however, the target root traits to improve yield potential still remain largely unknown. This study aimed to identify traits of seedling root system architecture (RSA) associated with yield and yield components in 226 recombinant inbred lines (RILs) derived from a cross between the bread wheat Triticum aestivum 'Forno' (small, wide root system) and spelt Triticum spelta 'Oberkulmer' (large, narrow root system). A 'pouch and wick' high-throughput phenotyping pipeline was used to determine the RSA traits of 13-day-old RIL seedlings. Two field experiments and one glasshouse experiment were carried out to investigate the yield, yield components and phenology, followed by identification of quantitative trait loci (QTLs). There was substantial variation in RSA traits between genotypes. Seminal root number and total root length were both positively associated with grains m -2 , grains per spike, above-ground biomass m -2 and grain yield. More seminal roots and longer total root length were also associated with delayed maturity and extended grain filling, likely to be a consequence of more grains being defined before anthesis. Additionally, the maximum width of the root system displayed positive relationships with spikes m -2 , grains m -2 and grain yield. Ten RILs selected for the longest total roots exhibited the same effects on yield and phenology as described above, compared with the ten lines with the shortest total roots. Genetic analysis revealed 38 QTLs for the RSA, and QTL coincidence between the root and yield traits was frequently observed, indicating tightly linked genes or pleiotropy, which concurs with the results of phenotypic correlation analysis. Based on the results from the Forno × Oberkulmer population, it is proposed that vigorous early root growth, particularly more seminal roots and longer total root length, is important to improve yield potential, and should be incorporated into wheat ideotypes in breeding. © The Author 2017. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com
A open loop guidance architecture for navigationally robust on-orbit docking
NASA Technical Reports Server (NTRS)
Chern, Hung-Sheng
1995-01-01
The development of an open-hop guidance architecture is outlined for autonomous rendezvous and docking (AR&D) missions to determine whether the Global Positioning System (GPS) can be used in place of optical sensors for relative initial position determination of the chase vehicle. Feasible command trajectories for one, two, and three impulse AR&D maneuvers are determined using constrained trajectory optimization. Early AR&D command trajectory results suggest that docking accuracies are most sensitive to vertical position errors at the initial conduction of the chase vehicle. Thus, a feasible command trajectory is based on maximizing the size of the locus of initial vertical positions for which a fixed sequence of impulses will translate the chase vehicle into the target while satisfying docking accuracy requirements. Documented accuracies are used to determine whether relative GPS can achieve the vertical position error requirements of the impulsive command trajectories. Preliminary development of a thruster management system for the Cargo Transfer Vehicle (CTV) based on optimal throttle settings is presented to complete the guidance architecture. Results show that a guidance architecture based on a two impulse maneuvers generated the best performance in terms of initial position error and total velocity change for the chase vehicle.
A robotic multi-channel platform for interstitial photodynamic therapy
Sharikova, Anna V.; Finlay, Jarod C.; Dimofte, Andreea; Zhu, Timothy C.
2015-01-01
A custom-made robotic multichannel platform for interstitial photodynamic therapy (PDT) and diffuse optical tomography (DOT) was developed and tested in a phantom experiment. The system, which was compatible with the operating room (OR) environment, had 16 channels for independent positioning of light sources and/or isotropic detectors in separate catheters. Each channel’s motor had an optical encoder for position feedback, with resolution of 1.5 mm, and a maximum speed of 5 cm/s. Automatic calibration of detector positions was implemented using an optical diode beam that defined the starting position of each motor, and by means of feedback algorithms controlling individual channels. As a result, the accuracy of zero position of 0.1 mm for all channels was achieved. We have also employed scanning procedures where detectors automatically covered the appropriate range around source positions. Thus, total scan time for a typical optical properties (OP) measurement throughout the phantom was about 1.5 minutes with point sources. The OP were determined based on the measured light fluence rates. These enhancements allow a tremendous improvement of treatment quality for a bulk tumor compared to the systems employed in previous clinical trials. PMID:25914794
40 CFR 141.63 - Maximum contaminant levels (MCLs) for microbiological contaminants.
Code of Federal Regulations, 2011 CFR
2011-07-01
... repeat sample or E. coli-positive repeat sample, or any total coliform-positive repeat sample following a fecal coliform-positive or E. coli-positive routine sample constitutes a violation of the MCL for total...
40 CFR 141.63 - Maximum contaminant levels (MCLs) for microbiological contaminants.
Code of Federal Regulations, 2010 CFR
2010-07-01
... repeat sample or E. coli-positive repeat sample, or any total coliform-positive repeat sample following a fecal coliform-positive or E. coli-positive routine sample constitutes a violation of the MCL for total...
A navigated mechatronic system with haptic features to assist in surgical interventions.
Pieck, S; Gross, I; Knappe, P; Kuenzler, S; Kerschbaumer, F; Wahrburg, J
2003-01-01
In orthopaedic surgery, the development of new computer-based technologies such as navigation systems and robotics will facilitate more precise, reproducible results in surgical interventions. There are already commercial systems available for clinical use, though these still have some limitations and drawbacks. This paper presents an alternative approach to a universal modular surgical assistant system for supporting less or minimally invasive surgery. The position of a mechatronic arm, which is part of the system, is controlled by a navigation system so that small patient movements are automatically detected and compensated for in real time. Thus, the optimal tool position can be constantly maintained without the need for rigid bone or patient fixation. Furthermore, a force control mode of the mechatronic assistant system, based on a force-torque sensor, not only increases safety during surgical interventions but also facilitates hand-driven direct positioning of the arm. A prototype has been successfully tested in clinical applications at the Orthopadische Universitätsklinik Frankfurt. For the first time worldwide, implantation of the cup prosthesis in total hip replacement surgery has been carried out with the assistance of a mechatronic arm. According to measurements by the digitizing system, operating tool angle deviation remained below 0.5 degrees, relative to the preoperative planning. The presented approach to a new kind of surgical mechatronic assistance system supports the surgeon as needed by optimal positioning of the surgical instruments. Due to its modular design, it is applicable to a wide range of tasks in surgical interventions, e.g., endoscope guidance, bone preparation, etc.
Fang, Ning; Sun, Wei
2015-04-21
A method, apparatus, and system for improved VA-TIRFM microscopy. The method comprises automatically controlled calibration of one or more laser sources by precise control of presentation of each laser relative a sample for small incremental changes of incident angle over a range of critical TIR angles. The calibration then allows precise scanning of the sample for any of those calibrated angles for higher and more accurate resolution, and better reconstruction of the scans for super resolution reconstruction of the sample. Optionally the system can be controlled for incident angles of the excitation laser at sub-critical angles for pseudo TIRFM. Optionally both above-critical angle and sub critical angle measurements can be accomplished with the same system.
Piñeiro, Juan; Ochoa-Hueso, Raúl; Delgado-Baquerizo, Manuel; Dobrick, Silvan; Reich, Peter B; Pendall, Elise; Power, Sally A
2017-11-10
Plant roots play a crucial role in regulating key ecosystem processes such as carbon (C) sequestration and nutrient solubilisation. Elevated (e)CO 2 is expected to alter the biomass of fine, coarse and total roots to meet increased demand for other resources such as water and nitrogen (N), however, the magnitude and direction of observed changes vary considerably between ecosystems. Here, we assessed how climate and soil properties mediate root responses to eCO 2 by comparing 24 field-based CO 2 experiments across the globe including a wide range of ecosystem types. We calculated response ratios (i.e. effect size) and used structural equation modelling (SEM) to achieve a system-level understanding of how aridity, mean annual temperature and total soil nitrogen simultaneously drive the response of total, coarse and fine root biomass to eCO 2 . Models indicated that increasing aridity limits the positive response of fine and total root biomass to eCO 2 , and that fine (but not coarse or total) root responses to eCO 2 are positively related to soil total N. Our results provide evidence that consideration of factors such as aridity and soil N status is crucial for predicting plant and ecosystem-scale responses to future changes in atmospheric CO 2 concentrations, and thus feedbacks to climate change.
Calibration of a Computer Based Instrumentation for Flight Research
NASA Technical Reports Server (NTRS)
Forsyth, T. J.; Reynolds, R. S. (Technical Monitor)
1997-01-01
NASA Ames Research Center has been investigating a Differential Global Positioning System (DGPS) for future use as a Category II/III landing system. The DGPS navigation system was developed and installed on a B200 King Air aircraft. Instrumentation that is not calibrated and verified as a total operating system can have errors or not work correctly. Systems need to be checked for cross talk and that they work together accurately. It is imperative that the instrumentation and computer do not affect aircraft avionics and instrumentation needed for aircraft operation. This paper discusses calibration and verification principles of a computer based instrumentation airborne system.
Centroid Position as a Function of Total Counts in a Windowed CMOS Image of a Point Source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wurtz, R E; Olivier, S; Riot, V
2010-05-27
We obtained 960,200 22-by-22-pixel windowed images of a pinhole spot using the Teledyne H2RG CMOS detector with un-cooled SIDECAR readout. We performed an analysis to determine the precision we might expect in the position error signals to a telescope's guider system. We find that, under non-optimized operating conditions, the error in the computed centroid is strongly dependent on the total counts in the point image only below a certain threshold, approximately 50,000 photo-electrons. The LSST guider camera specification currently requires a 0.04 arcsecond error at 10 Hertz. Given the performance measured here, this specification can be delivered with a singlemore » star at 14th to 18th magnitude, depending on the passband.« less
NASA Astrophysics Data System (ADS)
Tampubolon, Togi; Hutahaean, Juniar; Siregar, Suryani N. J.
2018-03-01
Underwater research often uses geomagnets. It is one of the geophysical methods for measuring magnetic field variations. This research was done to identify how the subsurface rock structure is and determine kinds of rock based on its susceptibility value in Siogung-ogung geothermal area, Pangururan, Samosir District. The tool measurement of total magnetic field called Proton Precission Magnetometer, positioning using Global Position System, and north axis determination using geological compass. Data collection was done randomly with total 51 measuring points obtained. Data analysis started with International geomagnetics Reference Field correction to obtain the total magnetic field anomaly. Then, the data analysis of total magnetic anomaly was done by using surfer program 12. To get a magnetic anomaly cross section used Magdc For Windows program. Magnetic measurement results indicated that the variation of magnetic field strength in each point with the lowest magnetic intensity value of 41785.67 nano tesla. The highest magnetic intensity value is 43140, 33. From the results of qualitative interpretation, the magnetic anomaly value is at -200.92 to 1154.45 whereas the quantitative interpretive results of model show the existence of degradation and andesitic rocks, with the value of susceptibility
Invik, Jesse; Barkema, Herman W; Massolo, Alessandro; Neumann, Norman F; Checkley, Sylvia
2017-10-01
With increasing stress on our water resources and recent waterborne disease outbreaks, understanding the epidemiology of waterborne pathogens is crucial to build surveillance systems. The purpose of this study was to explore techniques for describing microbial water quality in rural drinking water wells, based on spatiotemporal analysis, time series analysis and relative risk mapping. Tests results for Escherichia coli and coliforms from private and small public well water samples, collected between 2004 and 2012 in Alberta, Canada, were used for the analysis. Overall, 14.6 and 1.5% of the wells were total coliform and E. coli-positive, respectively. Private well samples were more often total coliform or E. coli-positive compared with untreated public well samples. Using relative risk mapping we were able to identify areas of higher risk for bacterial contamination of groundwater in the province not previously identified. Incorporation of time series analysis demonstrated peak contamination occurring for E. coli in July and a later peak for total coliforms in September, suggesting a temporal dissociation between these indicators in terms of groundwater quality, and highlighting the potential need to increase monitoring during certain periods of the year.
Stieler, F; Wenz, F; Abo-Madyan, Y; Schweizer, B; Polednik, M; Herskind, C; Giordano, F A; Mai, S
2016-11-01
The Gamma Knife Icon (Elekta AB, Stockholm, Sweden) allows frameless stereotactic treatment using a combination of cone beam computer tomography (CBCT), a thermoplastic mask system, and an infrared-based high-definition motion management (HDMM) camera system for patient tracking during treatment. We report on the first patient with meningioma at the left petrous bone treated with adaptive fractionated stereotactic radiotherapy (a-gkFSRT). The first patient treated with Gamma Knife Icon at our institute received MR imaging for preplanning before treatment. For each treatment fraction, a daily CBCT was performed to verify the actual scull/tumor position. The system automatically adapted the planned shot positions to the daily position and recalculated the dose distribution (online adaptive planning). During treatment, the HDMM system recorded the intrafractional patient motion. Furthermore, the required times were recorded to define a clinical treatment slot. Total treatment time was around 20 min. Patient positioning needed 0.8 min, CBCT positioning plus acquisition 1.65 min, CT data processing and adaptive planning 2.66 min, and treatment 15.6 min. The differences for the five daily CBCTs compared to the reference are for rotation: -0.59 ± 0.49°/0.18 ± 0.20°/0.05 ± 0.36° and for translation: 0.94 ± 0.52 mm/-0.08 ± 0.08 mm/-1.13 ± 0.89 mm. Over all fractions, an intrafractional movement of 0.13 ± 0.04 mm was observed. The Gamma Knife Icon allows combining the accuracy of the stereotactic Gamma Knife system with the flexibility of fractionated treatment with the mask system and CBCT. Furthermore, the Icon system introduces a new online patient tracking system to the clinical routine. The interfractional accuracy of patient positioning was controlled with a thermoplastic mask and CBCT.
Alnaghy, S; Cutajar, D L; Bucci, J A; Enari, K; Safavi-Naeini, M; Favoino, M; Tartaglia, M; Carriero, F; Jakubek, J; Pospisil, S; Lerch, M; Rosenfeld, A B; Petasecca, M
2017-02-01
BrachyView is a novel in-body imaging system which aims to provide LDR brachytherapy seeds position reconstruction within the prostate in real-time. The first prototype is presented in this study: the probe consists of a gamma camera featuring three single cone pinhole collimators embedded in a tungsten tube, above three, high resolution pixelated detectors (Timepix). The prostate was imaged with a TRUS system using a sagittal crystal with a 2.5mm slice thickness. Eleven needles containing a total of thirty 0.508U 125 I seeds were implanted under ultrasound guidance. A CT scan was used to localise the seed positions, as well as provide a reference when performing the image co-registration between the BrachyView coordinate system and the TRUS coordinate system. An in-house visualisation software interface was developed to provide a quantitative 3D reconstructed prostate based on the TRUS images and co-registered with the LDR seeds in situ. A rigid body image registration was performed between the BrachyView and TRUS systems, with the BrachyView and CT-derived source locations compared. The reconstructed seed positions determined by the BrachyView probe showed a maximum discrepancy of 1.78mm, with 75% of the seeds reconstructed within 1mm of their nominal location. An accurate co-registration between the BrachyView and TRUS coordinate system was established. The BrachyView system has shown its ability to reconstruct all implanted LDR seeds within a tissue equivalent prostate gel phantom, providing both anatomical and seed position information in a single interface. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Pettit, Neil E; Naiman, Robert J
2005-09-01
We investigated whether large woody debris (LWD) piles create nodes of environmental resources that contribute to the recovery of riparian vegetation and that also augment the heterogeneity and resilience of the riverine system. River and riparian systems are typified by a large degree of heterogeneity and complex interactions between abiotic and biotic elements. Disturbance such as floods re-distribute the resources, such as LWD, and thereby add greater complexity to the system. We examined this issue on a semi-arid savanna river where approximately a 100-year return interval flood in 2000 uprooted vegetation and deposited substantial LWD. We investigated the micro-environment within the newly established LWD piles and compared this with conditions at adjacent reference sites containing no LWD. We found soil nutrient concentrations to be significantly higher in LWD piles compared with the reference plots (total N +19%, available P +51%, and total C +36%). Environmental variables within LWD piles and reference sites varied with landscape position in the river-riparian landscape and with LWD pile characteristics. Observed differences were generally between piles located in the terrestrial and riparian areas as compared to piles located on the macro-channel floor. After 3 years the number and cover of woody species were significantly higher when associated with LWD piles, regardless of landscape position or pile type. We conclude that LWD piles formed after large floods act as resource nodes by accumulating fine sediments and by retaining soil nutrients and soil moisture. The subsequent influence of LWD deposition on riparian heterogeneity is discerned at several spatial scales including within and between LWD piles, across landscape positions and between channel types. LWD piles substantially influence the initial developmental of riparian vegetation as the system regenerates following large destructive floods.
Comparison of Observation Impacts in Two Forecast Systems using Adjoint Methods
NASA Technical Reports Server (NTRS)
Gelaro, Ronald; Langland, Rolf; Todling, Ricardo
2009-01-01
An experiment is being conducted to compare directly the impact of all assimilated observations on short-range forecast errors in different operational forecast systems. We use the adjoint-based method developed by Langland and Baker (2004), which allows these impacts to be efficiently calculated. This presentation describes preliminary results for a "baseline" set of observations, including both satellite radiances and conventional observations, used by the Navy/NOGAPS and NASA/GEOS-5 forecast systems for the month of January 2007. In each system, about 65% of the total reduction in 24-h forecast error is provided by satellite observations, although the impact of rawinsonde, aircraft, land, and ship-based observations remains significant. Only a small majority (50- 55%) of all observations assimilated improves the forecast, while the rest degrade it. It is found that most of the total forecast error reduction comes from observations with moderate-size innovations providing small to moderate impacts, not from outliers with very large positive or negative innovations. In a global context, the relative impacts of the major observation types are fairly similar in each system, although regional differences in observation impact can be significant. Of particular interest is the fact that while satellite radiances have a large positive impact overall, they degrade the forecast in certain locations common to both systems, especially over land and ice surfaces. Ongoing comparisons of this type, with results expected from other operational centers, should lead to more robust conclusions about the impacts of the various components of the observing system as well as about the strengths and weaknesses of the methodologies used to assimilate them.
Bulane, Atang; Hoosen, Anwar
2017-01-01
Rapid and accurate identification of pathogens is of utmost importance for management of patients. Current identification relies on conventional phenotypic methods which are time consuming. Matrix-assisted laser desorption/ionisation-time of flight mass spectrometry (MALDI-TOF MS) is based on proteomic profiling and allows for rapid identification of pathogens. We compared MALDI-TOF MS against two commercial systems, MicroScan Walkaway and VITEK 2 MS. Over a three-month period from July 2013 to September 2013, a total of 227 bacteria and yeasts were collected from an academic microbiology laboratory ( N = 121; 87 Gram-negatives, seven Gram-positives, 27 yeasts) and other laboratories ( N = 106; 35 Gram-negatives, 34 Gram-positives, 37 yeasts). Sixty-five positive blood cultures were initially processed with Bruker Sepsityper kit for direct identification. From the 65 blood culture bottles, four grew more than one bacterial pathogen and MALDI-TOF MS identified only one isolate. The blood cultures yielded 21 Gram-negatives, 43 Gram-positives and one Candida . There were 21 Escherirchia coli isolates which were reported by the MALDI-TOF MS as E. coli / Shigella . Of the total 292 isolates, discrepant results were found for one bacterial and three yeast isolates. Discrepant results were resolved by testing with the API system with MALDI-TOF MS showing 100% correlation. The MALDI-TOF MS proved to be very useful for rapid and reliable identification of bacteria and yeasts directly from blood cultures and after culture of other specimens. The difference in time to identification was significant for all isolates. However, for positive blood cultures with minimal sample preparation time there was a massive difference in turn-around time with great appreciation by clinicians.
IDEEA activity monitor: validity of activity recognition for lying, reclining, sitting and standing.
Jiang, Yuyu; Larson, Janet L
2013-03-01
Recent evidence demonstrates the independent negative effects of sedentary behavior on health, but there are few objective measures of sedentary behavior. Most instruments measure physical activity and are not validated as measures of sedentary behavior. The purpose of this study was to evaluate the validity of the IDEEA system's measures of sedentary and low-intensity physical activities: lying, reclining, sitting and standing. Thirty subjects, 14 men and 16 women, aged 23 to 77 years, body mass index (BMI) between 18 to 34 kg/m(2), participated in the study. IDEEA measures were compared to direct observation for 27 activities: 10 lying in bed, 3 lying on a sofa, 1 reclining in a lawn chair, 10 sitting and 3 standing. Two measures are reported, the percentage of activities accurately identified and the percentage of monitored time that was accurately labeled by the IDEEA system for all subjects. A total of 91.6% of all observed activities were accurately identified and 92.4% of the total monitored time was accurately labeled. The IDEEA system did not accurately differentiate between lying and reclining so the two activities were combined for calculating accuracy. Using this approach the IDEEA system accurately identified 96% of sitting activities for a total of 97% of the monitored sitting time, 99% and 99% for standing, 87% and 88% for lying in bed, 87% and 88% for lying on the sofa, and 83% and 83% for reclining on a lawn chair. We conclude that the IDEEA system accurately recognizes sitting and standing positions, but it is less accurate in identifying lying and reclining positions. We recommend combining the lying and reclining activities to improve accuracy. The IDEEA system enables researchers to monitor lying, reclining, sitting and standing with a reasonable level of accuracy and has the potential to advance the science of sedentary behaviors and low-intensity physical activities.
Emergency Flight Control Using Computer-Controlled Thrust
NASA Technical Reports Server (NTRS)
Burcham, Frank W., Jr.; Fullerton, C. Gordon; Stewart, James F.; Gilyard, Glenn B.; Conley, Joseph A.
1995-01-01
Propulsion Controlled Aircraft (PCA) systems are digital electronic control systems undergoing development to provide limited maneuvering ability through variations of individual engine thrusts in multiple-engine airplanes. Provide landing capability when control surfaces inoperable. Incorporated on existing and future airplanes that include digital engine controls, digital flight controls, and digital data buses, adding no weight for additional hardware to airplane. Possible to handle total failure of hydraulic system, depending on how surfaces respond to loss of hydraulic pressure, and broken control cables or linkages. Future airplanes incorporate data from Global Positioning System for guidance to any suitable emergency runway in world.
NASA Astrophysics Data System (ADS)
Ding, Wenwu; Teferle, Norman; Kaźmierski, Kamil; Laurichesse, Denis; Yuan, Yunbin
2017-04-01
Observations from multiple Global Navigation Satellite System (GNSS) can improve the performance of real-time (RT) GNSS meteorology, in particular of the Zenith Total Delay (ZTD) estimates. RT ZTD estimates in combination with derived precipitable water vapour estimates can be used for weather now-casting and the tracking of severe weather events. While a number of published literature has already highlighted this positive development, in this study we describe an operational RT system for extracting ZTD using a modified version of the PPP-wizard (with PPP denoting Precise Point Positioning). Multi-GNSS, including GPS, GLONASS and Galileo, observation streams are processed using a RT PPP strategy based on RT satellite orbit and clock products from the Centre National d'Etudes Spatiales (CNES). A continuous experiment for 30 days was conducted, in which the RT observation streams of 20 globally distributed stations were processed. The initialization time and accuracy of the RT troposphere products using single and/or multi-system observations were evaluated. The effect of RT PPP ambiguity resolution was also evaluated. The results revealed that the RT troposphere products based on single system observations can fulfill the requirements of the meteorological application in now-casting systems. We noted that the GPS-only solution is better than the GLONASS-only solution in both initialization and accuracy. While the ZTD performance can be improved by applying RT PPP ambiguity resolution, the inclusion of observations from multiple GNSS has a more profound effect. Specifically, we saw that the ambiguity resolution is more effective in improving the accuracy, whereas the initialization process can be better accelerated by multi-GNSS observations. Combining all systems, RT troposphere products with an average accuracy of about 8 mm in ZTD were achieved after an initialization process of approximately 9 minutes, which supports the application of multi-GNSS observations and ambiguity resolution for RT meteorological applications.
Lee, J W; Park, D J; Kang, J H; Choi, S E; Yim, Y R; Kim, J E; Lee, K E; Wen, L; Kim, T J; Park, Y W; Sung, Y K; Lee, S S
2016-11-01
Objectives The survival rate of patients with systemic lupus erythematosus has improved in the last few decades, but the rate of hospitalization and health care costs for these patients remain higher than in the general population. Thus, we evaluated the rate of hospitalization and associated risk factors in an inception cohort of Korean patients with lupus. Methods Of the 507 patients with systemic lupus erythematosus enrolled in the KORean lupus NETwork, we investigated an inception cohort consisting of 196 patients with systemic lupus erythematosus presenting within 6 months of diagnosis based on the American College of Rheumatology classification criteria. We evaluated the causes of hospitalization, demographic characteristics, and laboratory and clinical data at the time of systemic lupus erythematosus diagnosis of hospitalized patients and during a follow-up period. We calculated the hospitalization rate as the number of total hospitalizations divided by the disease duration, and defined "frequent hospitalization" as hospitalization more than once per year. Results Of the 196 patients, 117 (59.6%) were admitted to hospital a total of 257 times during the 8-year follow-up period. Moreover, 22 (11.2%) patients were hospitalized frequently. The most common reasons for hospitalization included disease flares, infection, and pregnancy-related morbidity. In the univariate regression analysis, malar rash, arthritis, pericarditis, renal involvement, fever, systemic lupus erythematosus disease activity index > 12, hemoglobin level < 10 mg/dl, albumin level < 3.5 mg/dl, and anti-Sjögren's syndrome A positivity were associated with frequent hospitalization. Finally, multivariate analysis showed that arthritis, pericarditis, and anti-Sjögren's syndrome A antibody positivity at the time of diagnosis were risk factors for frequent hospitalization. Conclusions Our results showed that frequent hospitalization occurred in 11.2% of hospitalized patients and arthritis, pericarditis, and anti-Sjögren's syndrome A antibody positivity at the time of diagnosis were risk factors for frequent hospitalization.
Using modern human cortical bone distribution to test the systemic robusticity hypothesis.
Baab, Karen L; Copes, Lynn E; Ward, Devin L; Wells, Nora; Grine, Frederick E
2018-06-01
The systemic robusticity hypothesis links the thickness of cortical bone in both the cranium and limb bones. This hypothesis posits that thick cortical bone is in part a systemic response to circulating hormones, such as growth hormone and thyroid hormone, possibly related to physical activity or cold climates. Although this hypothesis has gained popular traction, only rarely has robusticity of the cranium and postcranial skeleton been considered jointly. We acquired computed tomographic scans from associated crania, femora and humeri from single individuals representing 11 populations in Africa and North America (n = 228). Cortical thickness in the parietal, frontal and occipital bones and cortical bone area in limb bone diaphyses were analyzed using correlation, multiple regression and general linear models to test the hypothesis. Absolute thickness values from the crania were not correlated with cortical bone area of the femur or humerus, which is at odds with the systemic robusticity hypothesis. However, measures of cortical bone scaled by total vault thickness and limb cross-sectional area were positively correlated between the cranium and postcranium. When accounting for a range of potential confounding variables, including sex, age and body mass, variation in relative postcranial cortical bone area explained ∼20% of variation in the proportion of cortical cranial bone thickness. While these findings provide limited support for the systemic robusticity hypothesis, cranial cortical thickness did not track climate or physical activity across populations. Thus, some of the variation in cranial cortical bone thickness in modern humans is attributable to systemic effects, but the driving force behind this effect remains obscure. Moreover, neither absolute nor proportional measures of cranial cortical bone thickness are positively correlated with total cranial bone thickness, complicating the extrapolation of these findings to extinct species where only cranial vault thickness has been measured. Copyright © 2018 Elsevier Ltd. All rights reserved.
Global Positioning System III (GPS III)
2015-12-01
Vacuum (TVAC) testing on October 12, 2015, and successfully completed baseline TVAC testing on December 23, 2015 – a major system- level event...0.0 0.0 Total 4142.9 5285.2 N/A 5180.4 4269.8 5650.1 5557.4 Current APB Cost Estimate Reference SCP dated July 02, 2015 Confidence Level Confidence... Level of cost estimate for current APB: 60% The current APB is established at the 60% confidence level . This estimate is built upon the February 2015
High-speed large angle mammography tomosynthesis system
NASA Astrophysics Data System (ADS)
Eberhard, Jeffrey W.; Staudinger, Paul; Smolenski, Joe; Ding, Jason; Schmitz, Andrea; McCoy, Julie; Rumsey, Michael; Al-Khalidy, Abdulrahman; Ross, William; Landberg, Cynthia E.; Claus, Bernhard E. H.; Carson, Paul; Goodsitt, Mitchell; Chan, Heang-Ping; Roubidoux, Marilyn; Thomas, Jerry A.; Osland, Jacqueline
2006-03-01
A new mammography tomosynthesis prototype system that acquires 21 projection images over a 60 degree angular range in approximately 8 seconds has been developed and characterized. Fast imaging sequences are facilitated by a high power tube and generator for faster delivery of the x-ray exposure and a high speed detector read-out. An enhanced a-Si/CsI flat panel digital detector provides greater DQE at low exposure, enabling tomo image sequence acquisitions at total patient dose levels between 150% and 200% of the dose of a standard mammographic view. For clinical scenarios where a single MLO tomographic acquisition per breast may replace the standard CC and MLO views, total tomosynthesis breast dose is comparable to or below the dose in standard mammography. The system supports co-registered acquisition of x-ray tomosynthesis and 3-D ultrasound data sets by incorporating an ultrasound transducer scanning system that flips into position above the compression paddle for the ultrasound exam. Initial images acquired with the system are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Emmons, Samuel B.; Kang, Daekyoung; Acharya, Bijaya
2017-09-08
Here, we study the recombination process of three atoms scattering into an atom and diatomic molecule in heteronuclear mixtures of ultracold atomic gases with large and positive interspecies scattering length at finite temperature. We calculate the temperature dependence of the three-body recombination rates by extracting universal scaling functions that parametrize the energy dependence of the scattering matrix. We compare our results to experimental data for the 40K– 87Rb mixture and make a prediction for 6Li– 87Rb. We find that contributions from higher partial wave channels significantly impact the total rate and, in systems with particularly large mass imbalance, can evenmore » obliterate the recombination minima associated with the Efimov effect.« less
Identification of Recurrent Novae in M31
NASA Astrophysics Data System (ADS)
Shafter, Allen W.; Rector, T. A.; Schweizer, F.; Bryan, J.
2014-01-01
Over roughly the past century a total of more than 900 optical transient events have been recorded in M31, the vast majority of which are believed to represent eruptions of classical novae. The impressive dataset of nova positions put together by Pietsch (http://www.mpe.mpg.de m31novae/opt/m31/) provides the opportunity to search for multiple nova outbursts from the same progenitor system, and thus to characterize the population of recurrent novae (RNe) in M31. In order to identify RNe candidates, we have searched for spatial near coincidences among the 945 recorded novae given in the Pietsch catalog through the end of August 2013. Given that the positions of many of the early novae are quite uncertain, we have set our initial screen to include nova pairs with nominal separations less than or equal to 6 arcsec. We have identified a total of 102 novae that pass this coarse screen. Of these, 78 novae form 39 pairs, 15 form five triples, four novae are part of a quad, and five novae form a quint. As demonstrated by Shafter, Rice and Daub (2009, presented at the "Wild Stars in the Old West II" conference, mintaka.sdsu.edu/faculty/shafter/extragalactic_novae/RNePoster4.pdf), the majority of the 102 novae surviving our initial screen are expected to be associated with chance positional near coincidences (especially near the nucleus), and are not RNe. To decide which candidates are indeed RNe, we have undertaken a study to locate the original discovery plates, CCD images or published finding charts, and to perform the necessary astrometry to identify which of our candidate RNe are chance positional coincidences, and which are RNe. For each candidate, we estimate the probability that the object is a chance positional coincidence as in Shafter et al. (2009). To date, we have been successful in identifying finding charts or original images for most of the candidates, and have found a total of 23 nova outbursts in M31 associated with 10 systems that are almost certainly RNe.
AgIIS, Agricultural Irrigation Imaging System, design and application
NASA Astrophysics Data System (ADS)
Haberland, Julio Andres
Remote sensing is a tool that is increasingly used in agriculture for crop management purposes. A ground-based remote sensing data acquisition system was designed, constructed, and implemented to collect high spatial and temporal resolution data in irrigated agriculture. The system was composed of a rail that mounts on a linear move irrigation machine, and a small cart that runs back and forth on the rail. The cart was equipped with a sensors package that measured reflectance in four discrete wavelengths (550 nm, 660 nm, 720 nm, and 810 nm, all 10 nm bandwidth) and an infrared thermometer. A global positioning system and triggers on the rail indicated cart position. The data was postprocessed in order to generate vegetation maps, N and water status maps and other indices relevant for site-specific crop management. A geographic information system (GIS) was used to generate images of the field on any desired day. The system was named AgIIS (A&barbelow;gricultural I&barbelow;rrigation I&barbelow;maging S&barbelow;ystem). This ground based remote sensing acquisition system was developed at the Agricultural and Biosystems Engineering Department at the University of Arizona in conjunction with the U.S. Water Conservation Laboratory in Phoenix, as part of a cooperative study primarily funded by the Idaho National Environmental and Engineering Laboratory. A second phase of the study utilized data acquired with AgIIS during the 1999 cotton growing season to model petiole nitrate (PNO3 -) and total leaf N. A latin square experimental design with optimal and low water and optimal and low N was used to evaluate N status under water and no water stress conditions. Multivariable models were generated with neural networks (NN) and multilinear regression (MLR). Single variable models were generated from chlorophyll meter readings (SPAD) and from the Canopy Chlorophyll Content Index (CCCI). All models were evaluated against observed PNO3- and total leaf N levels. The NN models showed the highest correlation with PNO3- and total leaf N. AgIIS was a reliable and efficient data acquisition system for research and also showed potential for use in commercial farming systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ogunmolu, O; Gans, N; Jiang, S
Purpose: We propose a surface-image-guided soft robotic patient positioning system for maskless head-and-neck radiotherapy. The ultimate goal of this project is to utilize a soft robot to realize non-rigid patient positioning and real-time motion compensation. In this proof-of-concept study, we design a position-based visual servoing control system for an air-bladder-based soft robot and investigate its performance in controlling the flexion/extension cranial motion on a mannequin head phantom. Methods: The current system consists of Microsoft Kinect depth camera, an inflatable air bladder (IAB), pressured air source, pneumatic valve actuators, custom-built current regulators, and a National Instruments myRIO microcontroller. The performance ofmore » the designed system was evaluated on a mannequin head, with a ball joint fixed below its neck to simulate torso-induced head motion along flexion/extension direction. The IAB is placed beneath the mannequin head. The Kinect camera captures images of the mannequin head, extracts the face, and measures the position of the head relative to the camera. This distance is sent to the myRIO, which runs control algorithms and sends actuation commands to the valves, inflating and deflating the IAB to induce head motion. Results: For a step input, i.e. regulation of the head to a constant displacement, the maximum error was a 6% overshoot, which the system then reduces to 0% steady-state error. In this initial investigation, the settling time to reach the regulated position was approximately 8 seconds, with 2 seconds of delay between the command start of motion due to capacitance of the pneumatics, for a total of 10 seconds to regulate the error. Conclusion: The surface image-guided soft robotic patient positioning system can achieve accurate mannequin head flexion/extension motion. Given this promising initial Result, the extension of the current one-dimensional soft robot control to multiple IABs for non-rigid positioning control will be pursued.« less
Buchheit, Martin; Allen, Adam; Poon, Tsz Kit; Modonutti, Mattia; Gregson, Warren; Di Salvo, Valter
2014-12-01
Abstract During the past decade substantial development of computer-aided tracking technology has occurred. Therefore, we aimed to provide calibration equations to allow the interchangeability of different tracking technologies used in soccer. Eighty-two highly trained soccer players (U14-U17) were monitored during training and one match. Player activity was collected simultaneously with a semi-automatic multiple-camera (Prozone), local position measurement (LPM) technology (Inmotio) and two global positioning systems (GPSports and VX). Data were analysed with respect to three different field dimensions (small, <30 m 2 to full-pitch, match). Variables provided by the systems were compared, and calibration equations (linear regression models) between each system were calculated for each field dimension. Most metrics differed between the 4 systems with the magnitude of the differences dependant on both pitch size and the variable of interest. Trivial-to-small between-system differences in total distance were noted. However, high-intensity running distance (>14.4 km · h -1 ) was slightly-to-moderately greater when tracked with Prozone, and accelerations, small-to-very largely greater with LPM. For most of the equations, the typical error of the estimate was of a moderate magnitude. Interchangeability of the different tracking systems is possible with the provided equations, but care is required given their moderate typical error of the estimate.
Love, William J; Lehenbauer, Terry W; Kass, Philip H; Van Eenennaam, Alison L; Aly, Sharif S
2014-01-01
Several clinical scoring systems for diagnosis of bovine respiratory disease (BRD) in calves have been proposed. However, such systems were based on subjective judgment, rather than statistical methods, to weight scores. Data from a pair-matched case-control study on a California calf raising facility was used to develop three novel scoring systems to diagnose BRD in preweaned dairy calves. Disease status was assigned using both clinical signs and diagnostic test results for BRD-associated pathogens. Regression coefficients were used to weight score values. The systems presented use nasal and ocular discharge, rectal temperature, ear and head carriage, coughing, and respiratory quality as predictors. The systems developed in this research utilize fewer severity categories of clinical signs, require less calf handling, and had excellent agreement (Kappa > 0.8) when compared to an earlier scoring system. The first scoring system dichotomized all clinical predictors but required inducing a cough. The second scoring system removed induced cough as a clinical abnormality but required distinguishing between three levels of nasal discharge severity. The third system removed induced cough and forced a dichotomized variable for nasal discharge. The first system presented in this study used the following predictors and assigned values: coughing (induced or spontaneous coughing, 2 points), nasal discharge (any discharge, 3 points), ocular discharge (any discharge, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C or 102.5°F, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized "BRD positive" if their total score was ≥4. This system correctly classified 95.4% cases and 88.6% controls. The second presented system categorized the predictors and assigned weights as follows: coughing (spontaneous only, 2 points), mild nasal discharge (unilateral, serous, or watery discharge, 3 points), moderate to severe nasal discharge (bilateral, cloudy, mucoid, mucopurlent, or copious discharge, 5 points), ocular discharge (any discharge, 1 point), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized "BRD positive" if their total score was ≥4. This system correctly classified 89.3% cases and 92.8% controls. The third presented system used the following predictors and scores: coughing (spontaneous only, 2 points), nasal discharge (any, 4 points), ocular discharge (any, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized "BRD positive" if their total score was ≥5. This system correctly classified 89.4% cases and 90.8% controls. Each of the proposed systems offer few levels of clinical signs and data-based weights for on-farm diagnosis of BRD in dairy calves.
A Role for M-Matrices in Modelling Population Growth
ERIC Educational Resources Information Center
James, Glyn; Rumchev, Ventsi
2006-01-01
Adopting a discrete-time cohort-type model to represent the dynamics of a population, the problem of achieving a desired total size of the population under a balanced growth (contraction) and the problem of maintaining the desired size, once achieved, are studied. Properties of positive-time systems and M-matrices are used to develop the results,…
ERIC Educational Resources Information Center
Tellegen, Cassandra L.; Sanders, Matthew R.
2013-01-01
This systematic review and meta-analysis evaluated the treatment effects of a behavioral family intervention, Stepping Stones Triple P (SSTP) for parents of children with disabilities. SSTP is a system of five intervention levels of increasing intensity and narrowing population reach. Twelve studies, including a total of 659 families, met…
The total position-spread tensor: Spin partition
DOE Office of Scientific and Technical Information (OSTI.GOV)
El Khatib, Muammar, E-mail: elkhatib@irsamc.ups-tlse.fr; Evangelisti, Stefano, E-mail: stefano@irsamc.ups-tlse.fr; Leininger, Thierry, E-mail: Thierry.Leininger@irsamc.ups-tlse.fr
2015-03-07
The Total Position Spread (TPS) tensor, defined as the second moment cumulant of the position operator, is a key quantity to describe the mobility of electrons in a molecule or an extended system. In the present investigation, the partition of the TPS tensor according to spin variables is derived and discussed. It is shown that, while the spin-summed TPS gives information on charge mobility, the spin-partitioned TPS tensor becomes a powerful tool that provides information about spin fluctuations. The case of the hydrogen molecule is treated, both analytically, by using a 1s Slater-type orbital, and numerically, at Full Configuration Interactionmore » (FCI) level with a V6Z basis set. It is found that, for very large inter-nuclear distances, the partitioned tensor growths quadratically with the distance in some of the low-lying electronic states. This fact is related to the presence of entanglement in the wave function. Non-dimerized open chains described by a model Hubbard Hamiltonian and linear hydrogen chains H{sub n} (n ≥ 2), composed of equally spaced atoms, are also studied at FCI level. The hydrogen systems show the presence of marked maxima for the spin-summed TPS (corresponding to a high charge mobility) when the inter-nuclear distance is about 2 bohrs. This fact can be associated to the presence of a Mott transition occurring in this region. The spin-partitioned TPS tensor, on the other hand, has a quadratical growth at long distances, a fact that corresponds to the high spin mobility in a magnetic system.« less
Gordon, Sarah M; Elegino-Steffens, Diane U; Agee, Willie; Barnhill, Jason; Hsue, Gunther
2013-01-01
Upper respiratory tract infections (URIs) can be a serious burden to the healthcare system. The majority of URIs are viral in etiology, but definitive diagnosis can prove difficult due to frequently overlapping clinical presentations of viral and bacterial infections, and the variable sensitivity, and lengthy turn-around time of viral culture. We tested new automated nested multiplex PCR technology, the FilmArray® system, in the TAMC department of clinical investigations, to determine the feasibility of replacing the standard viral culture with a rapid turn-around system. We conducted a feasibility study using a single-blinded comparison study, comparing PCR results with archived viral culture results from a convenience sample of cryopreserved archived nasopharyngeal swabs from acutely ill ED patients who presented with complaints of URI symptoms. A total of 61 archived samples were processed. Viral culture had previously identified 31 positive specimens from these samples. The automated nested multiplex PCR detected 38 positive samples. In total, PCR was 94.5% concordant with the previously positive viral culture results. However, PCR was only 63.4% concordant with the negative viral culture results, owing to PCR detection of 11 additional viral pathogens not recovered on viral culture. The average time to process a sample was 75 minutes. We determined that an automated nested multiplex PCR is a feasible alternative to viral culture in an acute clinical setting. We were able to detect at least 94.5% as many viral pathogens as viral culture is able to identify, with a faster turn-around time. PMID:24052914
Patient positioning in radiotherapy based on surface imaging using time of flight cameras
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilles, M., E-mail: marlene.gilles@univ-brest.fr
2016-08-15
Purpose: To evaluate the patient positioning accuracy in radiotherapy using a stereo-time of flight (ToF)-camera system. Methods: A system using two ToF cameras was used to scan the surface of the patients in order to position them daily on the treatment couch. The obtained point clouds were registered to (a) detect translations applied to the table (intrafraction motion) and (b) predict the displacement to be applied in order to place the patient in its reference position (interfraction motion). The measures provided by this system were compared to the effectively applied translations. The authors analyzed 150 fractions including lung, pelvis/prostate, andmore » head and neck cancer patients. Results: The authors obtained small absolute errors for displacement detection: 0.8 ± 0.7, 0.8 ± 0.7, and 0.7 ± 0.6 mm along the vertical, longitudinal, and lateral axes, respectively, and 0.8 ± 0.7 mm for the total norm displacement. Lung cancer patients presented the largest errors with a respective mean of 1.1 ± 0.9, 0.9 ± 0.9, and 0.8 ± 0.7 mm. Conclusions: The proposed stereo-ToF system allows for sufficient accuracy and faster patient repositioning in radiotherapy. Its capability to track the complete patient surface in real time could allow, in the future, not only for an accurate positioning but also a real time tracking of any patient intrafraction motion (translation, involuntary, and breathing).« less
Patient positioning in radiotherapy based on surface imaging using time of flight cameras.
Gilles, M; Fayad, H; Miglierini, P; Clement, J F; Scheib, S; Cozzi, L; Bert, J; Boussion, N; Schick, U; Pradier, O; Visvikis, D
2016-08-01
To evaluate the patient positioning accuracy in radiotherapy using a stereo-time of flight (ToF)-camera system. A system using two ToF cameras was used to scan the surface of the patients in order to position them daily on the treatment couch. The obtained point clouds were registered to (a) detect translations applied to the table (intrafraction motion) and (b) predict the displacement to be applied in order to place the patient in its reference position (interfraction motion). The measures provided by this system were compared to the effectively applied translations. The authors analyzed 150 fractions including lung, pelvis/prostate, and head and neck cancer patients. The authors obtained small absolute errors for displacement detection: 0.8 ± 0.7, 0.8 ± 0.7, and 0.7 ± 0.6 mm along the vertical, longitudinal, and lateral axes, respectively, and 0.8 ± 0.7 mm for the total norm displacement. Lung cancer patients presented the largest errors with a respective mean of 1.1 ± 0.9, 0.9 ± 0.9, and 0.8 ± 0.7 mm. The proposed stereo-ToF system allows for sufficient accuracy and faster patient repositioning in radiotherapy. Its capability to track the complete patient surface in real time could allow, in the future, not only for an accurate positioning but also a real time tracking of any patient intrafraction motion (translation, involuntary, and breathing).
Increasing phytoplankton-available phosphorus and inhibition of macrophyte on phytoplankton bloom.
Dai, Yanran; Wu, Juan; Ma, Xiaohang; Zhong, Fei; Cui, Naxin; Cheng, Shuiping
2017-02-01
We assembled mesocosms to address the coherent mechanisms that an increasing phosphorus (P) concentration in water columns coupled with the phytoplankton bloom and identify the performance gap of regulating phytoplankton growth between two macrophyte species, Ceratophyllum demersum L. and Vallisneria spiralis L. Intense alkaline phosphatase activities (APA) were observed in the unplanted control, with their predominant part, phytoplankton APA (accounting for up to 44.7% of the total APA), and another large share, bacterial APA. These correspond with the large average concentration of total phosphorus (TP), total dissolved phosphorus (TDP) and soluble reactive (SRP) as well as high phytoplankton density in the water column. The consistency among P concentrations, phytoplankton density and APA, together with the positive impact of phytoplankton density on total APA revealed by the structural equation modelling (SEM), indicates that facilitated APA levels in water is an essential strategy for phytoplankton to enhance the available P. Furthermore, a positive interaction between phytoplankton APA and bacteria APA was detected, suggesting a potential collaboration between phytoplankton and bacteria to boost available P content in the water column. Both macrophyte species had a prominent performance on regulating phytoplankton proliferation. The phytoplankton density and quantum yield in C. demersum systems were all significantly lower (33.8% and 24.0%) than those in V. spiralis systems. Additionally, a greater decoupling effect of C. demersum on the relationship between P, APA, phytoplankton density, bacteria dynamic and quantum yield was revealed by SEM. These results imply that the preferred tactic of different species could lead to the performance gap. Copyright © 2016 Elsevier B.V. All rights reserved.
Aparicio, C
1994-10-01
To maintain osseointegration, it is essential that the prosthesis fit with total passivity because the absence of a periodontal ligament makes the implant unable to adapt its position to a nonpassive framework. The traditional system of building a metal framework by melting over mechanized pieces--called gold cylinders in the Brånemark system--has been modified so these pieces are joined to the metal framework by means of physicochemical bonding. This bond is achieved by treating the metallic surfaces with a Silicoater system and a composite resin cement that sets in the mouth using an improved cementing protocol. In this paper, the clinical viability of this new philosophy, shown over 2 years, is presented. A total of 64 prostheses (39 maxillary and 25 mandibular) supported by 214 abutments, with an average observation period of 9 months, were evaluated. The results show that it is possible to routinely obtain a ceramometal prosthesis with a totally passive circular fitting while maintaining the possibility of retrieval, thus making postceramic soldering unnecessary.
Faron, Matthew L; Buchan, Blake W; Vismara, Chiara; Lacchini, Carla; Bielli, Alessandra; Gesu, Giovanni; Liebregts, Theo; van Bree, Anita; Jansz, Arjan; Soucy, Genevieve; Korver, John; Ledeboer, Nathan A
2016-03-01
Recently, systems have been developed to create total laboratory automation for clinical microbiology. These systems allow for the automation of specimen processing, specimen incubation, and imaging of bacterial growth. In this study, we used the WASPLab to validate software that discriminates and segregates positive and negative chromogenic methicillin-resistant Staphylococcus aureus (MRSA) plates by recognition of pigmented colonies. A total of 57,690 swabs submitted for MRSA screening were enrolled in the study. Four sites enrolled specimens following their standard of care. Chromogenic agar used at these sites included MRSASelect (Bio-Rad Laboratories, Redmond, WA), chromID MRSA (bioMérieux, Marcy l'Etoile, France), and CHROMagar MRSA (BD Diagnostics, Sparks, MD). Specimens were plated and incubated using the WASPLab. The digital camera took images at 0 and 16 to 24 h and the WASPLab software determined the presence of positive colonies based on a hue, saturation, and value (HSV) score. If the HSV score fell within a defined threshold, the plate was called positive. The performance of the digital analysis was compared to manual reading. Overall, the digital software had a sensitivity of 100% and a specificity of 90.7% with the specificity ranging between 90.0 and 96.0 across all sites. The results were similar using the three different agars with a sensitivity of 100% and specificity ranging between 90.7 and 92.4%. These data demonstrate that automated digital analysis can be used to accurately sort positive from negative chromogenic agar cultures regardless of the pigmentation produced. Copyright © 2016 Faron et al.
Chang, Ching-Sheng; Chen, Su-Yueh; Lan, Yi-Ting
2012-11-21
No previous studies have addressed the integrated relationships among system quality, service quality, job satisfaction, and system performance; this study attempts to bridge such a gap with evidence-based practice study. The convenience sampling method was applied to the information system users of three hospitals in southern Taiwan. A total of 500 copies of questionnaires were distributed, and 283 returned copies were valid, suggesting a valid response rate of 56.6%. SPSS 17.0 and AMOS 17.0 (structural equation modeling) statistical software packages were used for data analysis and processing. The findings are as follows: System quality has a positive influence on service quality (γ11= 0.55), job satisfaction (γ21= 0.32), and system performance (γ31= 0.47). Service quality (β31= 0.38) and job satisfaction (β32= 0.46) will positively influence system performance. It is thus recommended that the information office of hospitals and developers take enhancement of service quality and user satisfaction into consideration in addition to placing b on system quality and information quality when designing, developing, or purchasing an information system, in order to improve benefits and gain more achievements generated by hospital information systems.
First-principle study of single TM atoms X (X=Fe, Ru or Os) doped monolayer WS2 systems
NASA Astrophysics Data System (ADS)
Zhu, Yuan-Yan; Zhang, Jian-Min
2018-05-01
We report the structural, magnetic and electronic properties of the pristine and single TM atoms X (X = Fe, Ru or Os) doped monolayer WS2 systems based on first-principle calculations. The results show that the W-S bond shows a stronger covalent bond, but the covalency is obviously weakened after the substitution of W atom with single X atoms, especially for Ru (4d75s1) with the easily lost electronic configuration. The smaller total energies of the doped systems reveal that the spin-polarized states are energetically favorable than the non-spin-polarized states, and the smallest total energy of -373.918 eV shows the spin-polarized state of the Os doped monolayer WS2 system is most stable among three doped systems. In addition, although the pristine monolayer WS2 system is a nonmagnetic-semiconductor with a direct band gap of 1.813 eV, single TM atoms Fe and Ru doped monolayer WS2 systems transfer to magnetic-HM with the total moments Mtot of 1.993 and 1.962 μB , while single TM atom Os doped monolayer WS2 systems changes to magnetic-metal with the total moments Mtot of 1.569 μB . Moreover, the impurity states with a positive spin splitting energies of 0.543, 0.276 and 0.1999 eV near the Fermi level EF are mainly contributed by X-dxy and X-dx2-y2 states hybridized with its nearest-neighbor atom W-dz2 states for Fe, Ru and Os doped monolayer WS2 system, respectively. Finally, we hope that the present study on monolayer WS2 will provide a useful theoretical guideline for exploring low-dimensional spintronic materials in future experiments.
Lens-mount stability trade-off: a survey exemplified for DUV wafer inspection objectives
NASA Astrophysics Data System (ADS)
Bouazzam, Achmed; Erbe, Torsten; Fahr, Stephan; Werschnik, Jan
2015-09-01
The position stability of optical elements is an essential part of the tolerance budget of an optical system because its compensation would require an alignment step after the lens has left the factory. In order to achieve a given built performance the stability error contribution needs to be known and accounted for. Given a high-end lens touching the edge of technology not knowing, under- or overestimating this contribution becomes a serious cost and risk factor. If overestimated the remaining parts of the budget need to be tighter. If underestimated the total project might fail. For many mounting principles the stability benchmark is based on previous systems or information gathered by elaborated testing of complete optical systems. This renders the development of a new system into a risky endeavour, because these experiences are not sufficiently precise and tend to be not transferable when scaling of the optical elements is intended. This contribution discusses the influences of different optical mounting concepts on the position stability using the example of high numerical aperture (HNA) inspection lenses working in the deep ultraviolet (DUV) spectrum. A method to investigate the positional stability is presented for selected mounting examples typical for inspection lenses.
Ozen, N S; Ogunc, D; Mutlu, D; Ongut, G; Baysan, B O; Gunseren, F
2011-01-01
Differentiation of Staphylococcus aureus (S. aureus) from coagulase-negative staphylococci is very important in blood stream infections. Identification of S. aureus and coagulase-negative staphylococci (CoNS) from blood cultures takes generally 18-24 h after positive signaling on continuously monitored automated blood culture system. In this study, we evaluated the performance of tube coagulase test (TCT), slide agglutination test (Dry Spot Staphytect Plus), conventional polymerase chain reaction (PCR) and LightCycler Staphylococcus MGrade kit directly from blood culture bottles to achieve rapid identification of S. aureus by using the BACTEC 9240 blood culture system. A total of 129 BACTEC 9240 bottles growing gram-positive cocci suggesting Staphylococci were tested directly from blood culture broths (BCBs) with TCT, Dry Spot Staphytect Plus, conventional PCR and LightCycler Staphylococcus MGrade kit for rapid identification of S. aureus. The sensitivities of the tests were 99, 68, 99 and 100%, respectively. Our results suggested that 2 h TCT was found to be simple and inexpensive method for the rapid identification of S. aureus directly from positive blood cultures.
SU-E-J-159: Analysis of Total Imaging Uncertainty in Respiratory-Gated Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suzuki, J; Okuda, T; Sakaino, S
Purpose: In respiratory-gated radiotherapy, the gating phase during treatment delivery needs to coincide with the corresponding phase determined during the treatment plan. However, because radiotherapy is performed based on the image obtained for the treatment plan, the time delay, motion artifact, volume effect, and resolution in the images are uncertain. Thus, imaging uncertainty is the most basic factor that affects the localization accuracy. Therefore, these uncertainties should be analyzed. This study aims to analyze the total imaging uncertainty in respiratory-gated radiotherapy. Methods: Two factors of imaging uncertainties related to respiratory-gated radiotherapy were analyzed. First, CT image was used to determinemore » the target volume and 4D treatment planning for the Varian Realtime Position Management (RPM) system. Second, an X-ray image was acquired for image-guided radiotherapy (IGRT) for the BrainLAB ExacTrac system. These factors were measured using a respiratory gating phantom. The conditions applied during phantom operation were as follows: respiratory wave form, sine curve; respiratory cycle, 4 s; phantom target motion amplitude, 10, 20, and 29 mm (which is maximum phantom longitudinal motion). The target and cylindrical marker implanted in the phantom coverage of the CT images was measured and compared with the theoretically calculated coverage from the phantom motion. The theoretical position of the cylindrical marker implanted in the phantom was compared with that acquired from the X-ray image. The total imaging uncertainty was analyzed from these two factors. Results: In the CT image, the uncertainty between the target and cylindrical marker’s actual coverage and the coverage of CT images was 1.19 mm and 2.50mm, respectively. In the Xray image, the uncertainty was 0.39 mm. The total imaging uncertainty from the two factors was 1.62mm. Conclusion: The total imaging uncertainty in respiratory-gated radiotherapy was clinically acceptable. However, an internal margin should be added to account for the total imaging uncertainty.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oliver, J. B.
Planetary substrate rotation for optical-coating deposition is evaluated based on initial and final positions for a given layer with different numbers of revolutions and various deposition-source locations. The influence of partial revolutions of the rotation system is analyzed relative to the total number of planetary revolutions in that layer to determine the relative impact on film thickness and uniformity. Furthermore, guidance is provided on the necessary planetary revolutions that should take place in each layer versus the expected error level in the layer thickness for the modeled system.
Sex-specific differences in the synaptonemal complex in the genus Oreochromis (Cichlidae).
Campos-Ramos, Rafael; Harvey, Simon C; Penman, David J
2009-04-01
Total synaptonemal complex (SC) lengths were estimated from Oreochromis aureus Steindachner (which has a WZ/ZZ sex determination system), O. mossambicus Peters and O. niloticus L. (both of which have XX/XY sex determination systems). The total SC length in oocytes was greater than that in spermatocytes in all three species (194 +/- 30 microm and 134 +/- 13 microm, 187 +/- 22 microm and 127 +/- 17 microm, 193 +/- 37 microm and 144 +/- 19 microm, respectively). These sex-specific differences did not appear to be influenced by the type of sex determination system (the female/male total SC length ratio was 1.45 in O. aureus, 1.47 in O. mossambicus and 1.34 in O. niloticus) and do not correlate with the lack of any overall sex-specific length differences in the current Oreochromis linkage map. Although based on data from relatively few species, there appears to be no consistent relationship between sex-specific SC lengths and linkage map lengths in fish. Neomale (hormonally masculinized genetic female) O. aureus and O. mossambicus had total SC lengths of 138 +/- 13 microm and 146 +/- 13 microm respectively, more similar to normal males than to normal females. These findings agree with data from other vertebrate species that suggest that phenotypic sex, rather than genotype, determines traits such as total SC length, chiasmata position and recombination pattern, at least for the autosomes.
Continuous positive airway pressure for the treatment of obstructive sleep apnea.
Nurwidya, Fariz; Susanto, Agus Dwi; Juzar, Dafsah A; Kobayashi, Isao; Yunus, Faisal
2016-01-01
Obstructive sleep apnea (OSA) is a recurrent episode of partial or complete upper airway obstruction during sleep despite ongoing respiratory efforts and is implicated as the risk factor of cardiovascular disease. The OSA syndrome is typified by recurring partial or total occlusion of the pharynx, sleep fragmentation, episodes of gasping, and, eventually, daytime sleepiness. If it is left untreated, OSA syndrome can cause hypertension, coronary artery disease congestive heart disease, insulin resistance and death. In this review, we describe the pathogenesis and diagnosis of OSA. We also focused on the continuous positive airway pressure (CPAP) as the main therapy for OSA. CPAP has been shown to provide benefit for not only respiratory system, but also for cardiovascular system and metabolic system. Finally, we discussed briefly about the issue of adherence of using CPAP that could contribute to lower compliant in patient with OSA.
Pull-pull position control of dual motor wire rope transmission.
Guo, Quan; Jiao, Zongxia; Yan, Liang; Yu, Qian; Shang, Yaoxing
2016-08-01
Wire rope transmission is very efficient because of the small total moving object mass. The wire rope could only transmit pulling force. Therefore it has to be kept in a tightened state during transmission; in high speed applications the dynamic performance depends on the rope's stiffness, which can be adjusted by the wire rope tension. To improve the system dynamic performance output, this paper proposes a novel pull-pull method based on dual motors connected by wire ropes, for precise, high speed position control applications. The method can regulate target position and wire rope tension simultaneously. Wire ropes remain in a pre-tightening state at all times, which prevents the influence of elasticity and reduces the position tracking error in the changing direction process. Simulations and experiments were conducted; the results indicate that both position precision and superior dynamic performance can be synchronously achieved. The research is relevant to space craft precision pointing instruments.
On the accuracy and reliability of predictions by control-system theory.
Bourbon, W T; Copeland, K E; Dyer, V R; Harman, W K; Mosley, B L
1990-12-01
In three experiments we used control-system theory (CST) to predict the results of tracking tasks on which people held a handle to keep a cursor even with a target on a computer screen. 10 people completed a total of 104 replications of the task. In each experiment, there were two conditions: in one, only the handle affected the position of the cursor; in the other, a random disturbance also affected the cursor. From a person's performance during Condition 1, we derived constants used in the CST model to predict the results of Condition 2. In two experiments, predictions occurred a few minutes before Condition 2; in one experiment, the delay was 1 yr. During a 1-min. experimental run, the positions of handle and cursor, produced by the person, were each sampled 1800 times, once every 1/30 sec. During a modeling run, the model predicted the positions of the handle and target for each of the 1800 intervals sampled in the experimental run. In 104 replications, the mean correlation between predicted and actual positions of the handle was .996; SD = .002.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li Heng; Sahoo, Narayan; Poenisch, Falk
Purpose: The purpose of this work was to assess the monitor unit (MU) values and position accuracy of spot scanning proton beams as recorded by the daily treatment logs of the treatment control system, and furthermore establish the feasibility of using the delivered spot positions and MU values to calculate and evaluate delivered doses to patients. Methods: To validate the accuracy of the recorded spot positions, the authors generated and executed a test treatment plan containing nine spot positions, to which the authors delivered ten MU each. The spot positions were measured with radiographic films and Matrixx 2D ion-chambers arraymore » placed at the isocenter plane and compared for displacements from the planned and recorded positions. Treatment logs for 14 patients were then used to determine the spot MU values and position accuracy of the scanning proton beam delivery system. Univariate analysis was used to detect any systematic error or large variation between patients, treatment dates, proton energies, gantry angles, and planned spot positions. The recorded patient spot positions and MU values were then used to replace the spot positions and MU values in the plan, and the treatment planning system was used to calculate the delivered doses to patients. The results were compared with the treatment plan. Results: Within a treatment session, spot positions were reproducible within {+-}0.2 mm. The spot positions measured by film agreed with the planned positions within {+-}1 mm and with the recorded positions within {+-}0.5 mm. The maximum day-to-day variation for any given spot position was within {+-}1 mm. For all 14 patients, with {approx}1 500 000 spots recorded, the total MU accuracy was within 0.1% of the planned MU values, the mean (x, y) spot displacement from the planned value was (-0.03 mm, -0.01 mm), the maximum (x, y) displacement was (1.68 mm, 2.27 mm), and the (x, y) standard deviation was (0.26 mm, 0.42 mm). The maximum dose difference between calculated dose to the patient based on the plan and recorded data was within 2%. Conclusions: The authors have shown that the treatment log file in a spot scanning proton beam delivery system is precise enough to serve as a quality assurance tool to monitor variation in spot position and MU value, as well as the delivered dose uncertainty from the treatment delivery system. The analysis tool developed here could be useful for assessing spot position uncertainty and thus dose uncertainty for any patient receiving spot scanning proton beam therapy.« less
Shariati, Laleh; Validi, Majid; Hasheminia, Ali Mohammad; Ghasemikhah, Reza; Kianpour, Fariborz; Karimi, Ali; Nafisi, Mohammad Reza; Tabatabaiefar, Mohammad Amin
2016-01-01
A diversity of virulence factors work together to create the pathogenicity of Staphylococcus aureus. These factors include cell surface components that promote adherence to surfaces as well as exoproteins such as Panton-Valentine leukocidin (PVL), encoded by the luk-PV genes, that invade or bypass the immune system and are toxic to the host, thereby enhancing the severity of infections caused by methicillin-resistant Staphylococcus aureus (MRSA). The aim of this study was to determine the frequency of PVL-positive MRSA strains by real-time PCR and their antibiotic susceptibility patterns by phenotypic test. In total, 284 Staphylococcus isolates, identified by phenotypic methods from clinical samples of Shahrekord University Hospitals, Shahrekord, Iran, were tested for nuc, mecA, and PVL genes by TaqMan real-time PCR. The antibiotic susceptibility patterns of PVL-containing MRSA strains were determined via the disk diffusion method. In total, 196 isolates (69%) were nuc positive (i.e., S. aureus); of those isolates, 96 (49%) were mecA positive (MRSA). Eighteen (18.8%) of the 96 MRSA positive and 3 (3%) of the 100 methicillin-susceptible Staphylococcus aureus (MSSA) strains were PVL positive. PVL-positive MRSA strains were mostly recovered from tracheal specimens. Eight PVL-positive MRSA strains were resistant to all the tested antibiotics except vancomycin. A significant correlation (P = 0.001) was found between the mecA positivity and the presence of luk-PV genes. Community acquired (CA)-MRSA is becoming a public health concern in many parts of the world, including Asian countries. The variable prevalence of luk-PV-positive MRSA isolates in different regions and their rather high frequency in pneumonia necessitate the application of rapid diagnostic methods such as real-time PCR to improve treatment effectiveness.
Incidence of tuberculous meningitis in France, 2000: a capture-recapture analysis.
Cailhol, J; Che, D; Jarlier, V; Decludt, B; Robert, J
2005-07-01
To estimate the incidence of culture-positive and culture-negative tuberculous meningitis (TBM) in France in 2000. Capture-recapture method using two unrelated sources of data: the tuberculosis (TB) mandatory notification system (MNTB), recording patients treated by anti-tuberculosis drugs, and a survey by the National Reference Centre (NRC) for mycobacterial drug resistance, recording culture-positive TBM. Of 112 cases of TBM reported to the MNTB, 28 culture-positive and 34 culture-negative meningitis cases were validated (17 duplicates, 3 cases from outside France, 21 false notifications, and 9 lost records were excluded). The NRC recorded 31 culture-positive cases, including 21 known by the MNTB. When the capture-recapture method was applied to the reported culture-positive meningitis cases, the estimated number of meningitis cases was 41 and the incidence was 0.7 cases per million. Sensitivity was 75.6% for the NRC, 68.3% for the MNTB, and 92.7% for both systems together. When sensitivity of the MNTB for culture-positive cases was applied to culture-negative meningitis, the total estimated number of culture-negative meningitis cases was 50 and the incidence was 0.85 cases per million. TBM is underestimated in France. Capture-recapture analysis using different sources to better estimate its incidence is of great interest.
Legionella species colonization in cooling towers: risk factors and assessment of control measures.
Mouchtouri, Varvara A; Goutziana, Georgia; Kremastinou, Jenny; Hadjichristodoulou, Christos
2010-02-01
Cooling towers can be colonized by Legionella spp, and inhalation of aerosols generated by their operation may cause Legionnaires' disease in susceptible hosts. Environmental investigations of Legionnaires' disease outbreaks linked with cooling towers have revealed poorly maintained systems, lack of control measures, and failure of system equipment. The purpose of this study was to identify Legionella-contaminated cooling towers, identify risk factors for contamination, and assess the effectiveness of control measures. A total of 96 cooling towers of public buildings were registered and inspected, and 130 samples were collected and microbiologically tested. Microbiological test results were associated with characteristics of cooling towers, water samples, inspection results, and maintenance practices. Of the total 96 cooling towers examined, 47 (48.9%) were colonized by Legionella spp, and 22 (22.9%) required remedial action. A total of 65 samples (50.0%) were positive (> or = 500 cfu L(-1)), and 30 (23%) were heavily contaminated (> or = 10(4) cfu L(-1)). Of the 69 isolates identified, 55 strains (79.7.%) were L pneumophila. Legionella colonization was positively associated with the absence of training on Legionella control (relative risk [RR] = 1.66; P = .02), absence of regular Legionella testing (RR = 2.07: P = .002), absence of sunlight protection (RR = 1.63: P = .02), with samples in which the free residual chlorine level in the water sample was < 0.5 mg/L (RR = 2.23; P = .01), and with total plate count (P =.001). Colonization was negatively associated with chemical disinfection (RR = 0.2; P = .0003) and with the presence of a risk assessment and management plan (RR = 0.12; P = .0005). A statistically significant higher age (P =.01) was found in legionellae-positive cooling towers (median, 17 years; interquartile range [IQR] =5.0 to 26.0 years) compared with noncolonized cooling towers (median age, 6 years; IQR =1.0 to 13.5 years). After the 22 legionellae-positive cooling towers were disinfected with chlorine, 2 (9%) of them remained positive for Legionella spp with a concentration > or = 1000 cfu L(-1). Cooling towers can be heavily colonized by Legionella spp and thus present a potential risk for infection. This study demonstrates the importance of a risk assessment and management plan. Water chlorination effectively reduces legionellae contamination. Proper training of cooling tower operators is paramount. Copyright 2010 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Sarikurkcu, Cengiz; Tepe, Bektas; Yamac, Mustafa
2008-09-01
The methanolic extracts of Lactarius deterrimus, Suillus collitinus, Boletus edulis, Xerocomus chrysenteron were analyzed for their antioxidant activities in different test systems namely beta-carotene/linoleic acid, DPPH free radical scavenging, reducing power and metal chelating activities in addition to their total phenolic and flavonoid contents. In beta-carotene/linoleic acid and DPPH systems, L. deterrimus and B. edulis showed the strongest activity patterns. Their activities were as strong as the positive controls. The reducing power of the species was excellent. Chelating capacity of the extracts was increased with the increasing concentration. On the other hand, B. edulis found to have the highest phenolic content. Total flavonoid content of S. collitinus found the superior to the other mushrooms.
2006-05-10
fragment CC120 and bromine The positive ion chemistry of oxalyl chloride has been analog CBrO. Total energies, enthalpies, and zero-point energy ( ZPE ...that Ar+ reacting with oxalyl bromide produced System G3a G2 b 70% CBrO+ and 30% Br+. trants-C2C1202(C2h, Ag) ZPE 0.019 93 0.019 93 COMPUTATIONAL...secondary ZPE 0.01708 0.01708 ions were carried out using the G3 compound method, pri- Total energy (0 K) -1146.717 00 -1145.904 66 marily in order to
Vilanova, Mar; Genisheva, Zlatina; Tubio, Miguel; Álvarez, Katia; Lissarrague, Jose Ramón; Oliveira, José Maria
2017-09-08
Viticultural practices influence both grape and wine quality. The influence of training systems on volatile composition was investigated for Albariño wine from Rías Baixas AOC in Northwest Spain. The odoriferous contribution of the compounds to the wine aroma was also studied. Volatile compounds belonging to ten groups (alcohols, C₆-compounds, ethyl esters, acetates, terpenols, C 13 -norisoprenoids, volatile phenols, volatile fatty acids, lactones and carbonyl compounds) were determined in Albariño wines from different training systems, Vertical Shoot-Positioned (VSP), Scott-Henry (SH), Geneva Double-Curtain (GDC), Arch-Cane (AC), and Parral (P) during 2010 and 2011 vintages. Wines from GDC showed the highest total volatile composition with the highest concentrations of alcohols, ethyl esters, fatty acids, and lactones families. However, the highest levels of terpenes and C 13 -norisoprenoids were quantified in the SH system. A fruitier aroma was observed in Albariño wines from GDC when odor activity values were calculated.
Frank, Andrew A.
1984-01-01
A control system and method for a power delivery system, such as in an automotive vehicle, having an engine coupled to a continuously variable ratio transmission (CVT). Totally independent control of engine and transmission enable the engine to precisely follow a desired operating characteristic, such as the ideal operating line for minimum fuel consumption. CVT ratio is controlled as a function of commanded power or torque and measured load, while engine fuel requirements (e.g., throttle position) are strictly a function of measured engine speed. Fuel requirements are therefore precisely adjusted in accordance with the ideal characteristic for any load placed on the engine.
Communication requirements of sparse Cholesky factorization with nested dissection ordering
NASA Technical Reports Server (NTRS)
Naik, Vijay K.; Patrick, Merrell L.
1989-01-01
Load distribution schemes for minimizing the communication requirements of the Cholesky factorization of dense and sparse, symmetric, positive definite matrices on multiprocessor systems are presented. The total data traffic in factoring an n x n sparse symmetric positive definite matrix representing an n-vertex regular two-dimensional grid graph using n exp alpha, alpha not greater than 1, processors are shown to be O(n exp 1 + alpha/2). It is O(n), when n exp alpha, alpha not smaller than 1, processors are used. Under the conditions of uniform load distribution, these results are shown to be asymptotically optimal.
Mahomed, Sharana; Dlamini-Mvelase, Nomonde R; Dlamini, Moses; Mlisana, Koleka
2017-01-01
For the optimal recovery of Mycobacterium tuberculosis from the BACTEC™ Mycobacterium Growth Indicator Tube 960™ system, an incubation period of 42-56 days is recommended by the manufacturer. Due to logistical reasons, it is common practice to follow an incubation period of 42 days. We undertook a retrospective study to document positive Mycobacterium Growth Indicator Tube cultures beyond the 42-day incubation period. In total, 98/110 (89%) were positive for M. tuberculosis complex. This alerted us to M. tuberculosis growth detection failure at 42 days.
Design and Implementation of a Smart Home System Using Multisensor Data Fusion Technology.
Hsu, Yu-Liang; Chou, Po-Huan; Chang, Hsing-Cheng; Lin, Shyan-Lung; Yang, Shih-Chin; Su, Heng-Yi; Chang, Chih-Chien; Cheng, Yuan-Sheng; Kuo, Yu-Chen
2017-07-15
This paper aims to develop a multisensor data fusion technology-based smart home system by integrating wearable intelligent technology, artificial intelligence, and sensor fusion technology. We have developed the following three systems to create an intelligent smart home environment: (1) a wearable motion sensing device to be placed on residents' wrists and its corresponding 3D gesture recognition algorithm to implement a convenient automated household appliance control system; (2) a wearable motion sensing device mounted on a resident's feet and its indoor positioning algorithm to realize an effective indoor pedestrian navigation system for smart energy management; (3) a multisensor circuit module and an intelligent fire detection and alarm algorithm to realize a home safety and fire detection system. In addition, an intelligent monitoring interface is developed to provide in real-time information about the smart home system, such as environmental temperatures, CO concentrations, communicative environmental alarms, household appliance status, human motion signals, and the results of gesture recognition and indoor positioning. Furthermore, an experimental testbed for validating the effectiveness and feasibility of the smart home system was built and verified experimentally. The results showed that the 3D gesture recognition algorithm could achieve recognition rates for automated household appliance control of 92.0%, 94.8%, 95.3%, and 87.7% by the 2-fold cross-validation, 5-fold cross-validation, 10-fold cross-validation, and leave-one-subject-out cross-validation strategies. For indoor positioning and smart energy management, the distance accuracy and positioning accuracy were around 0.22% and 3.36% of the total traveled distance in the indoor environment. For home safety and fire detection, the classification rate achieved 98.81% accuracy for determining the conditions of the indoor living environment.
Design and Implementation of a Smart Home System Using Multisensor Data Fusion Technology
Chou, Po-Huan; Chang, Hsing-Cheng; Lin, Shyan-Lung; Yang, Shih-Chin; Su, Heng-Yi; Chang, Chih-Chien; Cheng, Yuan-Sheng; Kuo, Yu-Chen
2017-01-01
This paper aims to develop a multisensor data fusion technology-based smart home system by integrating wearable intelligent technology, artificial intelligence, and sensor fusion technology. We have developed the following three systems to create an intelligent smart home environment: (1) a wearable motion sensing device to be placed on residents’ wrists and its corresponding 3D gesture recognition algorithm to implement a convenient automated household appliance control system; (2) a wearable motion sensing device mounted on a resident’s feet and its indoor positioning algorithm to realize an effective indoor pedestrian navigation system for smart energy management; (3) a multisensor circuit module and an intelligent fire detection and alarm algorithm to realize a home safety and fire detection system. In addition, an intelligent monitoring interface is developed to provide in real-time information about the smart home system, such as environmental temperatures, CO concentrations, communicative environmental alarms, household appliance status, human motion signals, and the results of gesture recognition and indoor positioning. Furthermore, an experimental testbed for validating the effectiveness and feasibility of the smart home system was built and verified experimentally. The results showed that the 3D gesture recognition algorithm could achieve recognition rates for automated household appliance control of 92.0%, 94.8%, 95.3%, and 87.7% by the 2-fold cross-validation, 5-fold cross-validation, 10-fold cross-validation, and leave-one-subject-out cross-validation strategies. For indoor positioning and smart energy management, the distance accuracy and positioning accuracy were around 0.22% and 3.36% of the total traveled distance in the indoor environment. For home safety and fire detection, the classification rate achieved 98.81% accuracy for determining the conditions of the indoor living environment. PMID:28714884
The Characteristics Sought by Public School Leaders of Applicants for Teaching Positions
ERIC Educational Resources Information Center
Stultz, Sherry L.
2015-01-01
This study examined the characteristics of teacher applicants that are sought by public school systems in the Commonwealth of Kentucky. The Superintendents of each of the public school districts in the Commonwealth were surveyed. A total of 99 respondents completed the survey (n = 99). This response rate of 57.2% was well-above the average for…
ERIC Educational Resources Information Center
Jeong, Allan; Lee, Woon Jee
2012-01-01
This study examined some of the methodological approaches used by students to construct causal maps in order to determine which approaches help students understand the underlying causes and causal mechanisms in a complex system. This study tested the relationship between causal understanding (ratio of root causes correctly/incorrectly identified,…
Sagi, Moshe; Nesher, Lior; Yagupsky, Pablo
2017-03-01
The performance of the Bactec FX blood culture system for detecting Brucella bacteremia within the routine 1-week incubation period was assessed in a prospective study conducted in an area in southern Israel in which Brucella melitensis is endemic. Aerobic vials (BD Bactec Plus Aerobic/F medium) inoculated with blood specimens obtained from adult patients with positive Rose-Bengal screening test results were monitored for 4 consecutive weeks, and blind subcultures of negative vials were performed on solid media on days 7 and 28. During a 16-month period, a total of 31 (35.2%) of 88 cultures, obtained from 19 (38.0%) of 50 patients, were positive for Brucella melitensis The blood culture instrument identified 30 (96.8%) of 31 positive vials within 7 days of incubation; the single positive vial that was missed by the automated readings was detected only by the blind subculture performed on day 28. It is concluded that the Bactec FX system is able to detect the vast majority of episodes of Brucella bacteremia within the 1-week incubation protocol instituted in most clinical microbiology laboratories and without the need to perform blind subcultures of negative vials, enabling early diagnosis and saving labor and incubation time and space. Copyright © 2017 American Society for Microbiology.
Bolotov, I N; Kolosova, Iu S; Podbolotskaia, M V; Potapov, G S; Grishchenko, I V
2013-01-01
The notion of a dynamic compensatory system is discussed, characterized by the alternation of species occupying the leading position in bumblebee taxocenoses, while the total density of these pollinators in island ecosystems remains at similar levels. The functioning of the compensatory system is regulated by both abiotic factors (the weather and climate) and biotic factors (competition for trophic resources). The stability of the system is determined by the presence of reserve compensatory species capable of rapid population growth against the background of depressed abundance of other species under changing environmental conditions.
NASA Technical Reports Server (NTRS)
Lanyi, Gabor E.; Roth, Titus
1988-01-01
Total ionospheric electron contents (TEC) were measured by global positioning system (GPS) dual-frequency receivers developed by the Jet Propulsion Laboratory. The measurements included P-code (precise ranging code) and carrier phase data for six GPS satellites during multiple five-hour observing sessions. A set of these GPS TEC measurements were mapped from the GPS lines of sight to the line of sight of a Faraday beacon satellite by statistically fitting the TEC data to a simple model of the ionosphere. The mapped GPS TEC values were compared with the Faraday rotation measurements. Because GPS transmitter offsets are different for each satellite and because some GPS receiver offsets were uncalibrated, the sums of the satellite and receiver offsets were estimated simultaneously with the TEC in a least squares procedure. The accuracy of this estimation procedure is evaluated indicating that the error of the GPS-determined line of sight TEC can be at or below 1 x 10 to the 16th el/sq cm. Consequently, the current level of accuracy is comparable to the Faraday rotation technique; however, GPS provides superior sky coverage.
Total oxidant/antioxidant status in jaundiced newborns before and after phototherapy.
Aycicek, Ali; Erel, Ozcan
2007-01-01
To assess the effect of phototherapy on serum oxidant and antioxidant status in hyperbilirubinemic full-term newborns. Thirty-four full-term infants from 3 to 10 days of age exposed to phototherapy were studied. The serum antioxidant status was assessed by measuring the total antioxidant capacity (TAC) and individual antioxidant components: vitamin C, uric acid, albumin, thiol contents and total bilirubin. The oxidant status was assessed by determining the total oxidant status (TOS), oxidative stress index (OSI) and individual oxidant components: malondialdehyde (MDA), and lipid hydroperoxide levels. Vitamin C, uric acid, total bilirubin and MDA concentration were significantly lower, whereas serum TOS, lipid hydroperoxide and OSI levels were significantly higher after phototherapy (p < 0.05). There were significant positive correlations between serum total bilirubin and MDA (r = 0.434, p = 0.001). Although the MDA level was reduced after phototherapy, phototherapy has a negative impact on numerous parts of the oxidant/antioxidant defense system in jaundiced full-term newborns, exposing them to potential oxidative stress.
Ryan, Michael J.
1988-01-01
A steam trap monitor positioned downstream of a steam trap in a closed steam system includes a first sensor (the combination of a hot finger and thermocouple well) for measuring the energy of condensate and a second sensor (a cold finger) for measuring the total energy of condensate and steam in the line. The hot finger includes one or more thermocouples for detecting condensate level and energy, while the cold finger contains a liquid with a lower boiling temperature than that of water. Vapor pressure from the liquid is used to do work such as displacing a piston or bellows in providing an indication of total energy (steam+condensate) of the system. Processing means coupled to and responsive to outputs from the thermocouple well hot and cold fingers subtracts the condensate energy as measured by the hot finger and thermocouple well from the total energy as measured by the cold finger to provide an indication of the presence of steam downstream from the trap indicating that the steam trap is malfunctioning.
Biocompatability of compomer restorative systems on nonexposed dental pulps of primate teeth.
Tarim, B; Hafez, A A; Suzuki, S H; Suzuki, S; Cox, C F
1997-01-01
This study evaluated the histologic response of total-etched and nonetched compomer restored cavity preparations. One hundred fifteen class 5 cavity preparations were placed in the teeth of four healthy adult monkeys at 7, 27, and 90 days. A 37% H3PO4 was applied for 10 seconds and rinsed in total-etched preparations. No statistical differences were seen in inflammatory reactions among total-etched or nonetched compomers at 7, 27, and 90 days. There were no statistical differences in inflammatory cell responses among all compomer systems in regard to time intervals. Pulpal responses of compomers were greater than IRM at each time period. Pulp responses were associated with stained bacteria in 32 of 89 compomer teeth. No necrotic pulps were seen in any teeth. Statistical data show a positive correlation (P < 0.05) between bacterial presence and pulpal inflammation. IRM pulps showed no inflammation or bacterial staining. Compomers are biologically compatible with pulp tissues when bacteria are excluded.
Observations of Two Sprite-Producing Storms in Colorado
NASA Technical Reports Server (NTRS)
Lang, Timothy J.; Lyons, Walter A.; Cummer, Steven A.; Fuchs, Brody R.; Dolan, Brenda; Rutledge, Steven A.; Krehbiel, Paul; Rison, William; Stanley, Mark; Ashcraft, Thomas
2016-01-01
Two sprite-producing thunderstorms were observed on 8 and 25 June 2012 in northeastern Colorado by a combination of low-light cameras, a lightning mapping array, polarimetric and Doppler radars, the National Lightning Detection Network, and charge moment change measurements. The 8 June event evolved from a tornadic hailstorm to a larger multicellular system that produced 21 observed positive sprites in 2 h. The majority of sprites occurred during a lull in convective strength, as measured by total flash rate, flash energy, and radar echo volume. Mean flash area spiked multiple times during this period; however, total flash rates still exceeded 60 min(sup 1), and portions of the storm featured a complex anomalous charge structure, with midlevel positive charge near 20degC. The storm produced predominantly positive cloud-to-ground lightning. All sprite-parent flashes occurred on the northeastern flank of the storm, where strong westerly upper level flow was consistent with advection of charged precipitation away from convection, providing a pathway for stratiform lightning. The 25 June event was another multicellular hailstorm with an anomalous charge structure that produced 26 positive sprites in less than 1 h. The sprites again occurred during a convective lull, with relatively weaker reflectivity and lower total flash rate but relatively larger mean flash area. However, all sprite parents occurred in or near convection and tapped charge layers in adjacent anvil cloud. The results demonstrate the sprite production by convective ground strokes in anomalously charged storms and also indicate that sprite production and convective vigor are inversely related in mature storms.
Sano, Daisuke; Yabuki, Kenichiro; Arai, Yasuhiro; Tanabe, Teruhiko; Chiba, Yoshihiro; Nishimura, Goshi; Takahashi, Hideaki; Yamanaka, Shoji; Oridate, Nobuhiko
2018-06-01
The purpose of this study is to validate the applicability of new TNM classification for human papillomavirus (HPV)-related oropharyngeal cancer (OPC) in the 8th edition of the American Joint Committee on Cancer (AJCC)/Union for International Cancer Control (UICC) TNM staging system in Japan. A total of 91 OPC patients treated with radiation-based therapy between November 2001 and July 2015 were analyzed retrospectively in this study. HPV infection status was evaluated using tumor p16 expression. 40 OPC patients (44.0%) had HPV-positive disease in this study. The distribution of disease stage of HPV-positive OPC patients dramatically changed from the 7th edition to the 8th edition of AJCC/UICC TNM classification. However, neither the 8th edition nor the 7th edition of the AJCC/UICC TNM staging system could adequately predict outcomes of HPV-positive OPC patients in our patient series. On the other hand, our multivariate analysis indicated that matted nodes and age ≥63 were independent prognostic factors for progression-free survival. In addition, HPV-positive OPC patients with stage I without matted nodes showed significantly better overall and progression-free survival compared with those with stage I with matted nodes and stages II and III in the 8th edition of the AJCC/UICC TNM staging system (P=0.008, and P=0.043, respectively). Our results suggested that matted nodes of HPV-positive OPC patients might be additionally examined to apply the 8th edition of AJCC/UICC TNM classification for more adequate predicting outcomes of HPV-positive OPC patients. Copyright © 2017 Elsevier B.V. All rights reserved.
A spin-recovery parachute system for light general-aviation airplanes
NASA Technical Reports Server (NTRS)
Bradshaw, C.
1980-01-01
A tail mounted spin recovery parachute system was designed and developed for use on light general aviation airplanes. The system was designed for use on typical airplane configurations, including low wing, high wing, single engine and twin engine designs. A mechanically triggered pyrotechnic slug gun is used to forcibly deploy a pilot parachute which extracts a bag that deploys a ring slot spin recovery parachute. The total system weighs 8.2 kg. System design factors included airplane wake effects on parachute deployment, prevention of premature parachute deployment, positive parachute jettison, compact size, low weight, system reliability, and pilot and ground crew safety. Extensive ground tests were conducted to qualify the system. The recovery parachute was used successfully in flight 17 times.
Lemmetty, Kaisa; Häyrinen, Eija
2005-01-01
In this paper we evaluate the implementation of the operation management system in the Central Finland Health Care District. The implementation of the operation management system changed the practice of operation management for the surgical clinic and concerned 500 personnel in total. A survey was carried out to investigate the end users' views on the system's usefulness, usability and the training and user support provided. The users' possibilities to accomplish their tasks and the kind of obstacles they face in operation management were explored. The assessment revealed that more end support is needed after the system implementation, even though a generally positive attitude towards the system was manifested among the staff.
Lazennec, Jean-Yves; Rousseau, Marc-Antoine; Brusson, Adrien; Folinais, Dominique; Amel, Maria; Clarke, Ian; Pour, Aidin Eslam
2015-01-01
More total hip arthroplasty (THA) is performed worldwide and especially in younger and more active patients compared to earlier decades. One of the focuses of THA research in the future will be on optimizing the radiological follow-up of these patients using 2D and 3D measurements of implants position while reducing the radiation dose delivered. Low-dose EOS® imaging is an innovative slot-scanning radiograph system providing valuable information in patient functional positions (standing, sitting and even squatting positions). EOS has been proven accurate and reliable without significant inconvenience caused by the metallic artifacts of implants. The ability to obtain precise data on implant orientation according to the patient posture opens new perspectives for a comprehensive analysis of the pelvic frontal and sagittal balance and its potential impact on implants function and failures. We report our 8 years experience on our first 300 THA patients using this technology routinely for pre and post op evaluation. Our results will be compared and confronted with the actual literature about this innovative technology. We shall especially emphasize our experience about patients with abnormal posture and the evolution of the subject over time, because the phenomenon of an aging spine is frequently associated with the process of aging hips. PMID:25861404
Monte Carlo studies and optimization for the calibration system of the GERDA experiment
NASA Astrophysics Data System (ADS)
Baudis, L.; Ferella, A. D.; Froborg, F.; Tarka, M.
2013-11-01
The GERmanium Detector Array, GERDA, searches for neutrinoless double β decay in 76Ge using bare high-purity germanium detectors submerged in liquid argon. For the calibration of these detectors γ emitting sources have to be lowered from their parking position on the top of the cryostat over more than 5 m down to the germanium crystals. With the help of Monte Carlo simulations, the relevant parameters of the calibration system were determined. It was found that three 228Th sources with an activity of 20 kBq each at two different vertical positions will be necessary to reach sufficient statistics in all detectors in less than 4 h of calibration time. These sources will contribute to the background of the experiment with a total of (1.07±0.04(stat)-0.19+0.13(sys))×10-4 cts/(keV kg yr)) when shielded from below with 6 cm of tantalum in the parking position.
Hayashi, T; Kurokawa, M; Miyakawa, M; Aizawa, T; Kanaki, A; Saitoh, A; Ishioka, K
1994-01-01
Photostereometry has widely been applied to the measurement of mandibular movements in 6 degrees of freedom. In order to improve the accuracy of this measurement, we developed a system utilizing small LEDs mounted on the jaws in redundant numbers and a 5000 pixel linear charge-coupled device (CCD) as a photo-sensor. A total of eight LEDs are mounted on the jaws, in two sets of four, by means of connecting facebows, each weighing approximately 55 g. The position of the LEDs are detected in three-dimensions by two sets of three CCD cameras, located bilaterally. The position and orientation of the mandible are estimated from the positions of all LEDs measured in the sense of least-squares, thereby effectively reducing the measurement errors. The static overall accuracy at all tooth and condylar points was considered to lie within 0.19 and 0.34 mm, respectively, from various accuracy verification tests.
[Health expenditures, income inequality, and the marginalization index in Mexico's health system].
Pinzón Florez, Carlos Eduardo; Reveiz, Ludovic; Idrovo, Alvaro J; Reyes Morales, Hortensia
2014-01-01
Evaluate the effect of the relationship among public health expenditures, income inequality, and the marginalization index on maternal and child mortality in Mexico, to determine the effect of these factors on health system performance from a technical efficiency perspective. An ecological study of 32 Mexican states. Correlations were estimated between maternal and infant mortality and public health expenditures in total per capita, federal per capita, and state per capita for the years 2000, 2005, and 2010 (Gini coefficient and marginalization index). Linear regressions were used to explore the association of these variables with health indicators in the state systems. Negative correlations were observed for the marginalization index and Gini coefficient with regard to life expectancy at birth (-0.62 and -0.28 respectively). Furthermore, there was a positive correlation of 0.59 between the marginalization index and infant mortality (P <0.05). Multiple linear regression models revealed a negative effect of the marginalization index and Gini coefficient on health out-comes. Federal funding had a positive effect on system performance in terms of health indicators. Health system reform in Mexico has had a positive impact on the country's health indicators; federal financial investment seems to be effective in this regard. Social determinants have an important effect on health system performance, and analysis using multisectoral and multidisciplinary approaches are needed in addressing them.
Akduman Alaşehir, Elçin; Balıkçı, Ahmet; Partal, Mualla; Çatmabacak, Gülay; Yaman, Görkem
2016-09-01
Effective diagnosis of tuberculosis is of great importance for transmission control and treatment success. The purpose of this study is to evaluate microscopic examination results of Ehrlich-Ziehl Neelsen (EZN) and Auramine-Rhodamine staining methods and automated BACTEC MGIT 960™ system and Löwenstein-Jensen (L-J) culture results of various clinical samples in the light of recent data from the world and Turkey. Specimens that were sent from various clinics to Sureyyapasa Chest Diseases and Chest Surgery Training and Research Hospital Microbiology Laboratory from January 2012 to December 2015 were evaluated retrospectively. From a total of 62456 samples; 60923 (97.5%) were pulmonary and 1533 (2.5%) were non-pulmonary samples, especially pleura. 2853 (4.6%) Acid-resistant bacilli (ARB) positivity was detected and mycobacterial culture positivity was in total 12.2%. 7076 (93%) and 535 (7%) mycobacteria other than tuberculosis (MOTT) strains were isolated. In 356 specimens the cultures were negative in despite the positive ARB results. Considering mycobacterial culture as the gold standard; the sensitivity, specificity, positive and negative predictive values of ARB microscopy were 32.8%, 99.4%, 87.5% and 91.4%, respectively. The contamination rates in total were within acceptable limits being 2.7% for L-J and 3.8% for MGIT. Analysis of our data indicated that the sensitivity of microscopy is low and it should be evaluated together with the mycobacterial culture to rule out tuberculosis infection. With the use of fluorescent staining and also L-J and MGIT broth together for routine culture since 2013; ARB false negativity rate was observed to fall to 51.7% from 74.1% compared to the years. The follow-up of data such as the sensitivity of microscopy, culture positivity, false-positivity and false-negativity rates and contamination values is of great importance in terms of assessing compliance with laboratory quality standards and contributing to the surveillance studies.
Sweet bee venom pharmacopuncture for chemotherapy-induced peripheral neuropathy.
Yoon, Jeungwon; Jeon, Ju-Hyun; Lee, Yeon-Weol; Cho, Chong-Kwan; Kwon, Ki-Rok; Shin, Ji-Eun; Sagar, Stephen; Wong, Raimond; Yoo, Hwa-Seung
2012-08-01
Chemotherapy-induced peripheral neuropathy (CIPN) is sensory and motor nerve damage to the peripheral nervous system caused by chemotherapeutic agents. It often causes pain and other varying degrees of neuropathic symptoms accompanied by functional limitations and reduced quality of life. Currently, there is no standard treatment protocol for the treatment of CIPN. In need of more research to develop new therapeutic options focusing on their safety, efficacy, and long-term sustained clinical effects, a pilot study of sweet bee venom pharmacopuncture (SBVP) for CIPN was conducted to build up preliminary efficacy data in the process of preparing for a future larger scale randomized controlled SBVP trial for CIPN. We conducted a prospective case series by analyzing the clinical observations made of CIPN patients treated with SBVP. A total of 11 eligible consecutive CIPN patients who visited East-West Cancer Center from June 1, 2010, to February 28, 2011, were treated with total of six SBVP treatments given within the 3-week period. The outcomes were measured using World Health Organization Common Toxicity Criteria for Peripheral neuropathy (WHO grading system), Patient Neurotoxicity Questionnaire (PNQ), Visual Analogue System (VAS), and Health-Related Quality of Life (HRQOL) collected at the baseline, post-second, fourth, and the final treatment. Patients were followed 3 weeks into no intervention to determine the sustained effects of pharmacopuncture. Both of the WHO CIPN grade and PNQ scores have shown a decrease in the level of neuropathy. VAS pain level has also shown a great decrease and improvement in patients' quality of life have also been detected though modest. Changes in WHO grade, VAS and Total HRQOL scores between the baseline and after the last treatment session were significant. Changes in WHO grade, Total PNQ, PNQ-sensory, VAS, Total HRQOL, and HRQOL-functional scores between the baseline and the 3-week follow-up were significant. The positive result of the study supports the potential value of conducting a fully powered trial to explore further efficacy of SBVP for CIPN. However a single positive result within this pilot study must be interpreted with caution. Copyright © 2012. Published by Elsevier B.V.
Carruth, Rob; Flynn, Pool; Donald, R.; Anderson, Carl E.
2007-01-01
The U.S. Geological Survey monitors land subsidence and aquifer-system compaction caused by ground-water depletion in Tucson Basin and Avra Valley - two of the three alluvial basins within the Tucson Active Management Area. In spring 1987, the Global Positioning System was used to measure horizontal and vertical positions for bench marks at 43 sites to establish a network for monitoring land subsidence in Tucson Basin and Avra Valley. Between 1987 and 2005, the original number of subsidence monitoring stations was gradually increased to more than 100 stations to meet the need for information in the growing metropolitan area. Data from approximately 60 stations common to the Global Positioning System surveys done after an initial survey in 1987 are used to document land subsidence. For the periods of comparison, average land-surface deformation generally is less than the maximum subsidence at an individual station and takes into account land-surface recovery from elastic aquifer-system compaction. Between 1987 and 1998, as much as 3.2 inches of subsidence occurred in Tucson Basin and as much as 4 inches of subsidence occurred in Avra Valley. For the 31 stations that are common to both the 1987 and 1998 Global Positioning System surveys, the average subsidence during the 11-year period was about 0.5 inch in Tucson Basin and about 1.2 inches in Avra Valley. For the approximately 60 stations that are common to both the 1998 and 2002 Global Positioning System surveys, the data indicate that as much as 3.5 inches of subsidence occurred in Tucson Basin and as much as 1.1 inches of subsidence occurred in Avra Valley. The average subsidence for the 4-year period is about 0.4 inch in Tucson Basin and 0.6 inch in Avra Valley. Between the 2002 and the 2005 Global Positioning System surveys, the data indicate that as much as 0.2 inch of subsidence occurred in Tucson Basin and as much as 2.2 inches of subsidence occurred in Avra Valley. The average subsidence for the 3-year period is about 0.7 inch in Avra Valley. Between 1987 and 2004-05, land subsidence was greater in Avra Valley than in Tucson Basin on the basis of the average cumulative subsidence for the stations that were common to the original Global Positioning System survey in 1987. The average total subsidence during the 17- to 18-year period was about 1.3 inches in Tucson Basin and about 2.8 inches in Avra Valley. Three stations in Tucson Basin showed subsidence greater than 4 inches for the period - 5 inches at stations C45 and X419 and 4.1 inches at station PA4. In Avra Valley, two stations showed subsidence for the 17- to 18-year period greater than 4 inches - 4.3 inches at station AV25 and 4.8 inches at station SA105. In 1983, fourteen wells were fitted with borehole extensometers to monitor water-level fluctuations and aquifer-system compaction. Continuous records of water level and aquifer-system compaction indicate that as much as 45 feet of water-level decline and 4 inches of aquifer-system compaction occurred in Tucson Basin from January 1989 through December, 2005. In Avra Valley, extensometer data indicate that as much as 55 feet of water-level decline and 1.7 inches of aquifer-system compaction occurred during the same time period. Rates of compaction vary throughout the extensometer network, with the greater rates of compaction being associated with areas of greater water-level decline and more compressible sediments. In Avra Valley, data from the Global Positioning System surveys indicate that more than half of the total subsidence of the land surface may be the result of aquifer-system compaction below the portion of the aquifer instrumented with the vertical extensometers. For the area in the northern part of Tucson Basin between the Rillito and Santa Cruz rivers, an Interferometric Synthetic Aperture Radar interferogram indicates that about 1.65 inches of subsidence occurred between 2003 and 2006. Between 2002 and 2004, the Global Positioning System
Han, Houzeng; Wang, Jian; Wang, Jinling; Tan, Xinglong
2015-01-01
The integration of Global Navigation Satellite Systems (GNSS) carrier phases with Inertial Navigation System (INS) measurements is essential to provide accurate and continuous position, velocity and attitude information, however it is necessary to fix ambiguities rapidly and reliably to obtain high accuracy navigation solutions. In this paper, we present the notion of combining the Global Positioning System (GPS), the BeiDou Navigation Satellite System (BDS) and low-cost micro-electro-mechanical sensors (MEMS) inertial systems for reliable navigation. An adaptive multipath factor-based tightly-coupled (TC) GPS/BDS/INS integration algorithm is presented and the overall performance of the integrated system is illustrated. A twenty seven states TC GPS/BDS/INS model is adopted with an extended Kalman filter (EKF), which is carried out by directly fusing ambiguity fixed double-difference (DD) carrier phase measurements with the INS predicted pseudoranges to estimate the error states. The INS-aided integer ambiguity resolution (AR) strategy is developed by using a dynamic model, a two-step estimation procedure is applied with adaptively estimated covariance matrix to further improve the AR performance. A field vehicular test was carried out to demonstrate the positioning performance of the combined system. The results show the TC GPS/BDS/INS system significantly improves the single-epoch AR reliability as compared to that of GPS/BDS-only or single satellite navigation system integrated strategy, especially for high cut-off elevations. The AR performance is also significantly improved for the combined system with adaptive covariance matrix in the presence of low elevation multipath related to the GNSS-only case. A total of fifteen simulated outage tests also show that the time to relock of the GPS/BDS signals is shortened, which improves the system availability. The results also indicate that TC integration system achieves a few centimeters accuracy in positioning based on the comparison analysis and covariance analysis, even in harsh environments (e.g., in urban canyons), thus we can see the advantage of positioning at high cut-off elevations that the combined GPS/BDS brings. PMID:25875191
Han, Houzeng; Wang, Jian; Wang, Jinling; Tan, Xinglong
2015-04-14
The integration of Global Navigation Satellite Systems (GNSS) carrier phases with Inertial Navigation System (INS) measurements is essential to provide accurate and continuous position, velocity and attitude information, however it is necessary to fix ambiguities rapidly and reliably to obtain high accuracy navigation solutions. In this paper, we present the notion of combining the Global Positioning System (GPS), the BeiDou Navigation Satellite System (BDS) and low-cost micro-electro-mechanical sensors (MEMS) inertial systems for reliable navigation. An adaptive multipath factor-based tightly-coupled (TC) GPS/BDS/INS integration algorithm is presented and the overall performance of the integrated system is illustrated. A twenty seven states TC GPS/BDS/INS model is adopted with an extended Kalman filter (EKF), which is carried out by directly fusing ambiguity fixed double-difference (DD) carrier phase measurements with the INS predicted pseudoranges to estimate the error states. The INS-aided integer ambiguity resolution (AR) strategy is developed by using a dynamic model, a two-step estimation procedure is applied with adaptively estimated covariance matrix to further improve the AR performance. A field vehicular test was carried out to demonstrate the positioning performance of the combined system. The results show the TC GPS/BDS/INS system significantly improves the single-epoch AR reliability as compared to that of GPS/BDS-only or single satellite navigation system integrated strategy, especially for high cut-off elevations. The AR performance is also significantly improved for the combined system with adaptive covariance matrix in the presence of low elevation multipath related to the GNSS-only case. A total of fifteen simulated outage tests also show that the time to relock of the GPS/BDS signals is shortened, which improves the system availability. The results also indicate that TC integration system achieves a few centimeters accuracy in positioning based on the comparison analysis and covariance analysis, even in harsh environments (e.g., in urban canyons), thus we can see the advantage of positioning at high cut-off elevations that the combined GPS/BDS brings.
Volpe, Maria Grazia; De Cunzo, Fausta; Siano, Francesco; Paolucci, Marina; Barbarisi, Costantina; Cammarota, Giancarlo
2014-01-01
The purpose of this study was to investigate three types of extraction methods of extra virgin olive oil (EVOO) from the same cultivar (Ortice olive cultivar): traditional or pressing (T) system, decanter centrifugation (DC) system and a patented horizontal axis decanter centrifugation (HADC) system. Oil samples were subjected to chemical analyses: free acidity, peroxide value, ultraviolet light absorption K232 and K270, total polyphenols, antioxidant capacity, volatile compounds and olfactory characteristics by electronic nose. The two centrifugation systems showed better free acidity and peroxides value but total polyphenol content was particularly high in extra virgin olive oil produced by patented HADC system. Same volatile substances that positively characterize the oil aroma were found in higher amount in the two centrifugation systems, although some differences have been detected between DC and HADC system, other were found in higher amount in extra virgin olive oil produced by T system. The electronic nose analysis confirmed these results, principal component analysis (PCA) and correlation matrix showed the major differences between EVOO produced by T and HADC system. Taken together the results showed that DC and HADC systems produce EVOO with better characteristics than T system and patented HADC is the best extraction system.
Sinks for nitrogen inputs in terrestrial ecosystems: a meta-analysis of 15N tracer field studies
Templer, P.H.; Mack, M.C.; Chapin, F. S.; Christenson, L.M.; Compton, J.E.; Crook, H.D.; Currie, W.S.; Curtis, C.J.; Dail, D.B.; D'Antonio, C. M.; Emmett, B.A.; Epstein, H.E.; Goodale, C.L.; Gundersen, P.; Hobbie, S.E.; Holland, K.; Hooper, D.U.; Hungate, B.A.; Lamontagne, S.; Nadelhoffer, K.J.; Osenberg, C.W.; Perakis, S.S.; Schleppi, P.; Schimel, J.; Schmidt, I.K.; Sommerkorn, M.; Spoelstra, J.; Tietema, A.; Wessel, W.W.; Zak, D.R.
2012-01-01
Effects of anthropogenic nitrogen (N) deposition and the ability of terrestrial ecosystems to store carbon (C) depend in part on the amount of N retained in the system and its partitioning among plant and soil pools. We conducted a meta-analysis of studies at 48 sites across four continents that used enriched 15N isotope tracers in order to synthesize information about total ecosystem N retention (i.e., total ecosystem 15N recovery in plant and soil pools) across natural systems and N partitioning among ecosystem pools. The greatest recoveries of ecosystem 15N tracer occurred in shrublands (mean, 89.5%) and wetlands (84.8%) followed by forests (74.9%) and grasslands (51.8%). In the short term (15N tracer application), total ecosystem 15N recovery was negatively correlated with fine-root and soil 15N natural abundance, and organic soil C and N concentration but was positively correlated with mean annual temperature and mineral soil C:N. In the longer term (3–18 months after 15N tracer application), total ecosystem 15N retention was negatively correlated with foliar natural-abundance 15N but was positively correlated with mineral soil C and N concentration and C: N, showing that plant and soil natural-abundance 15N and soil C:N are good indicators of total ecosystem N retention. Foliar N concentration was not significantly related to ecosystem 15N tracer recovery, suggesting that plant N status is not a good predictor of total ecosystem N retention. Because the largest ecosystem sinks for 15N tracer were below ground in forests, shrublands, and grasslands, we conclude that growth enhancement and potential for increased C storage in aboveground biomass from atmospheric N deposition is likely to be modest in these ecosystems. Total ecosystem 15N recovery decreased with N fertilization, with an apparent threshold fertilization rate of 46 kg N·ha-1·yr-1 above which most ecosystems showed net losses of applied 15N tracer in response to N fertilizer addition.
Sinks for nitrogen inputs in terrestrial ecosystems: a meta-analysis of 15N tracer field studies.
Templer, P H; Mack, M C; Chapin, F S; Christenson, L M; Compton, J E; Crook, H D; Currie, W S; Curtis, C J; Dail, D B; D'Antonio, C M; Emmett, B A; Epstein, H E; Goodale, C L; Gundersen, P; Hobbie, S E; Holland, K; Hooper, D U; Hungate, B A; Lamontagne, S; Nadelhoffer, K J; Osenberg, C W; Perakis, S S; Schleppi, P; Schimel, J; Schmidt, I K; Sommerkorn, M; Spoelstra, J; Tietema, A; Wessel, W W; Zak, D R
2012-08-01
Effects of anthropogenic nitrogen (N) deposition and the ability of terrestrial ecosystems to store carbon (C) depend in part on the amount of N retained in the system and its partitioning among plant and soil pools. We conducted a meta-analysis of studies at 48 sites across four continents that used enriched 15N isotope tracers in order to synthesize information about total ecosystem N retention (i.e., total ecosystem 15N recovery in plant and soil pools) across natural systems and N partitioning among ecosystem pools. The greatest recoveries of ecosystem 15N tracer occurred in shrublands (mean, 89.5%) and wetlands (84.8%) followed by forests (74.9%) and grasslands (51.8%). In the short term (< 1 week after 15N tracer application), total ecosystem 15N recovery was negatively correlated with fine-root and soil 15N natural abundance, and organic soil C and N concentration but was positively correlated with mean annual temperature and mineral soil C:N. In the longer term (3-18 months after 15N tracer application), total ecosystem 15N retention was negatively correlated with foliar natural-abundance 15N but was positively correlated with mineral soil C and N concentration and C:N, showing that plant and soil natural-abundance 15N and soil C:N are good indicators of total ecosystem N retention. Foliar N concentration was not significantly related to ecosystem 15N tracer recovery, suggesting that plant N status is not a good predictor of total ecosystem N retention. Because the largest ecosystem sinks for 15N tracer were below ground in forests, shrublands, and grasslands, we conclude that growth enhancement and potential for increased C storage in aboveground biomass from atmospheric N deposition is likely to be modest in these ecosystems. Total ecosystem 15N recovery decreased with N fertilization, with an apparent threshold fertilization rate of 46 kg N x ha(-1) x yr(-1) above which most ecosystems showed net losses of applied 15N tracer in response to N fertilizer addition.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thiyagarajan, Rajesh; Karrthick, KP; Kataria, Tejinder
Purpose: Performing DQA for Bilateral (B-L) breast tomotherapy is a challenging task due to the limitation of any commercially available detector array or film. Aim of this study is to perform DQA for B-L breast tomotherapy plan using MLC fluence sinogram. Methods: Treatment plan was generated on Tomotherapy system for B-L breast tumour. B-L breast targets were given 50.4 Gy prescribed over 28 fractions. Plan is generated with 6 MV photon beam & pitch was set to 0.3. As the width of the total target is 39 cm (left & right) length is 20 cm. DQA plan delivered without anymore » phantom on the mega voltage computed tomography (MCVT) detector system. The pulses recorded by MVCT system were exported to the delivery analysis software (Tomotherapy Inc.) for reconstruction. The detector signals are reconstructed to a sonogram and converted to MLC fluence sonogram. The MLC fluence sinogram compared with the planned fluence sinogram. Also point dose measured with cheese phantom and ionization chamber to verify the absolute dose component Results: Planned fluence sinogram and reconstructed MLC fluence sinogram were compared using Gamma metric. MLC positional difference and intensity of the beamlet were used as parameters to evaluate gamma. 3 mm positional difference and 3% beamlet intensity difference were used set for gamma calculation. A total of 26784 non-zero beamlets were included in the analysis out of which 161 beamlets had gamma more than 1. The gamma passing rate found to be 99.4%. Point dose measurements were within 1.3% of the calculated dose. Conclusion: MLC fluence sinogram based delivery quality assurance performed for bilateral breast irradiation. This would be a suitable alternate for large volume targets like bilateral breast, Total body irradiation etc. However conventional method of DQA should be used to validate this method periodically.« less
NASA Astrophysics Data System (ADS)
Shoushtari, M. A.; Sadeghi-Niaraki, H.
2014-10-01
The growing trend in technological advances and Micro Electro Mechanical Systems (MEMS) has targeted for intelligent human lives. Accordingly, Ubiquitous Computing Approach was proposed by Mark Weiser. This paper proposes an ubiquitous surveying solution in Geometrics and surveying field. Ubiquitous Surveying provides cost-effective, smart and available surveying techniques while traditional surveying equipment are so expensive and have small availability specially in indoor and daily surveying jobs. In order to have a smart surveying instrument, different information technology methods and tools like Triangle method, Received Signal Strength Indicator (RSSI) method and laser sensor are used. These new ways in combine with surveying equations introduces a modern surveying equipment called Ubi-Total Station that also employed different sensors embedded in smartphone and mobile stand. RSSI-based localization and Triangle method technique are easy and well known methods to predict the position of an unknown node in indoor environments whereas additional measures are required for a sufficient accuracy. In this paper the main goal is to introduce the Ubiquitous Total Station as a development in smart and ubiquitous GIS. In order to public use of the surveying equipment, design and implementation of this instrument has been done. Conceptual model of Smartphone-based system is designed for this study and based on this model, an Android application as a first sample is developed. Finally the evaluations shows that absolute errors in X and Y calculation are 0.028 and 0.057 meter respectively. Also RMSE of 0.26 was calculated in RSSI method for distance measurement. The high price of traditional equipment and their requirement for professional surveyors has given way to intelligent surveying. In the suggested system, smartphones can be used as tools for positioning and coordinating geometric information of objects.
40 CFR 141.805 - Notification to passengers and crew.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., repeat or follow-up total coliform-positive or E. coli-positive sample result in accordance with § 141... samples in response to a sample result that is E. coli-positive in accordance with § 141.803(g); (4... response to a sample result that is total coliform-positive and E. coli-negative in accordance with § 141...
40 CFR 141.805 - Notification to passengers and crew.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., repeat or follow-up total coliform-positive or E. coli-positive sample result in accordance with § 141... samples in response to a sample result that is E. coli-positive in accordance with § 141.803(g); (4... response to a sample result that is total coliform-positive and E. coli-negative in accordance with § 141...
Mekki, Hemza; Benzineb, Omar; Boukhetala, Djamel; Tadjine, Mohamed; Benbouzid, Mohamed
2015-07-01
The fault-tolerant control problem belongs to the domain of complex control systems in which inter-control-disciplinary information and expertise are required. This paper proposes an improved faults detection, reconstruction and fault-tolerant control (FTC) scheme for motor systems (MS) with typical faults. For this purpose, a sliding mode controller (SMC) with an integral sliding surface is adopted. This controller can make the output of system to track the desired position reference signal in finite-time and obtain a better dynamic response and anti-disturbance performance. But this controller cannot deal directly with total system failures. However an appropriate combination of the adopted SMC and sliding mode observer (SMO), later it is designed to on-line detect and reconstruct the faults and also to give a sensorless control strategy which can achieve tolerance to a wide class of total additive failures. The closed-loop stability is proved, using the Lyapunov stability theory. Simulation results in healthy and faulty conditions confirm the reliability of the suggested framework. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.
2014-01-01
Background The purpose of the study was twofold: first, to determine whether there is a statistically significant difference in the metal ion levels among three different large-head metal-on-metal (MOM) total hip systems. The second objective was to assess whether position of the implanted prostheses, patient demographics or factors such as activity levels influence overall blood metal ion levels and whether there is a difference in the functional outcomes between the systems. Methods In a cross-sectional cohort study, three different metal-on-metal total hip systems were assessed: two monoblock heads, the Durom socket (Zimmer, Warsaw, IN, USA) and the Birmingham socket (Smith and Nephew, Memphis, TN, USA), and one modular metal-on-metal total hip system (Pinnacle, Depuy Orthopedics, Warsaw, IN, USA). Fifty-four patients were recruited, with a mean age of 59.7 years and a mean follow-up time of 41 months (12 to 60). Patients were evaluated clinically, radiologically and biochemically. Statistical analysis was performed on all collected data to assess any differences between the three groups in terms of overall blood metal ion levels and also to identify whether there was any other factor within the group demographics and outcomes that could influence the mean levels of Co and Cr. Results Although the functional outcome scores were similar in all three groups, the blood metal ion levels in the larger monoblock large heads (Durom, Birmingham sockets) were significantly raised compared with those of the Pinnacle group. In addition, the metal ion levels were not found to have a statistically significant relationship to the anteversion or abduction angles as measured on the radiographs. Conclusions When considering a MOM THR, the use of a monoblock large-head system leads to higher elevations in whole blood metal ions and offers no advantage over a smaller head modular system. PMID:24472283
Hip rotation range of motion in sitting and prone positions in healthy Japanese adults
Han, Heonsoo; Kubo, Akira; Kurosawa, Kazuo; Maruichi, Shizuka; Maruyama, Hitoshi
2015-01-01
[Purpose] The aim of this study was to elucidate the difference in hip external and internal rotation ranges of motion (ROM) between the prone and sitting positions. [Subjects] The subjects included 151 students. [Methods] Hip rotational ROM was measured with the subjects in the prone and sitting positions. Two-way repeated measures analysis of variance (ANOVA) was used to analyze ipsilateral hip rotation ROM in the prone and sitting positions in males and females. The total ipsilateral hip rotation ROM was calculated by adding the measured values for external and internal rotations. [Results] Ipsilateral hip rotation ROM revealed significant differences between two positions for both left and right internal and external rotations. Hip rotation ROM was significantly higher in the prone position than in the sitting position. Hip rotation ROM significantly differed between the men and women. Hip external rotation ROM was significantly higher in both positions in men; conversely, hip internal rotation ROM was significantly higher in both positions in women. [Conclusion] Hip rotation ROM significantly differed between the sexes and between the sitting and prone positions. Total ipsilateral hip rotation ROM, total angle of external rotation, and total angle of internal rotation of the left and right hips greatly varied, suggesting that hip joint rotational ROM is widely distributed. PMID:25729186
Altuntas, Nilgun; Turkyilmaz, Canan; Yildiz, Havva; Kulali, Ferit; Hirfanoglu, Ibrahim; Onal, Esra; Ergenekon, Ebru; Koç, Esin; Atalay, Yıldız
2014-05-01
We aimed to evaluate the validity and reliability of the Infant Breastfeeding Assessment Tool (IBFAT), the Mother Baby Assessment (MBA) Tool, and the LATCH scoring system. Mothers who delivered healthy, full-term infants in the Obstetrics & Gynecology Service of Gazi University, Ankara, Turkey, between December 2013 and January 2014 and their infants were included in the study. Forty-six randomly selected breastfeeding sessions were monitored and scored simultaneously by three researchers (Raters 1, 2, and 3) using LATCH, IBFAT, and the MBA Tool. Researchers put the score sheets in an envelope in order to hide them from each other. The compatibility of the scores given by three researchers was assessed by statistical methods. We found positive and significant correlation coefficients between 0.81 to 0.88 for the total MBA score, between 0.90 to 0.95 for the total IBFAT score, and between 0.85 to 0.91 for the total LATCH score. Correlation coefficients testing these three tools ranged from 0.71 to 0.88, with the minimum value being noted for the correlation between LATCH and IBFAT scores and the maximum value being noted for the correlation between LATCH and MBA scores. We found positive and significant correlations between researchers' scores for 46 observations using the three assessment tools. This study showed that these above-mentioned tools were compatible for the assessment of the efficiency of breastfeeding.
Kinect based real-time position calibration for nasal endoscopic surgical navigation system
NASA Astrophysics Data System (ADS)
Fan, Jingfan; Yang, Jian; Chu, Yakui; Ma, Shaodong; Wang, Yongtian
2016-03-01
Unanticipated, reactive motion of the patient during skull based tumor resective surgery is the source of the consequence that the nasal endoscopic tracking system is compelled to be recalibrated. To accommodate the calibration process with patient's movement, this paper developed a Kinect based Real-time positional calibration method for nasal endoscopic surgical navigation system. In this method, a Kinect scanner was employed as the acquisition part of the point cloud volumetric reconstruction of the patient's head during surgery. Then, a convex hull based registration algorithm aligned the real-time image of the patient head with a model built upon the CT scans performed in the preoperative preparation to dynamically calibrate the tracking system if a movement was detected. Experimental results confirmed the robustness of the proposed method, presenting a total tracking error within 1 mm under the circumstance of relatively violent motions. These results point out the tracking accuracy can be retained stably and the potential to expedite the calibration of the tracking system against strong interfering conditions, demonstrating high suitability for a wide range of surgical applications.
Franceschi, J-P; Sbihi, A
2014-10-01
The precision of bone cuts and the positioning of components influence the functionality and longevity of total knee arthroplasty (TKA). The objective of this study was to evaluate the results of TKA, performed after 3D preoperative templating, with the prosthesis implanted using custom cutting guides (Knee-Plan system, Symbios Orthopédie SA). This prospective study investigated 107 TKAs. Three-dimensional preoperative templating was carried out on the surface views and CT views to analyze the deformation of the lower limb and plan the implantation. The components were positioned in an individualized manner to realign the lower limb and provide ligament balance based on bone landmarks. Final component positioning was analyzed in the three planes with a postoperative CT scan. The preoperative and 1 year follow-up IKS and WOMAC scores were collected and compared. All the cutting guides were stable and functional. Femoral component planning was reproduced with 0 ± 2 precision in the frontal plane (94%± 3), 2 ± 3 in the sagittal plane, and 0 ± 2 in the transverse plane. The precision of the tibial component was reproduced with 0 ± 2 precision in the frontal plane (93%± 3) and 0 ± 4 in the sagittal plane. The HKA angle increased from 177 ± 7 preoperatively to 180 ± 3 at 1 year of follow-up. The IKS and WOMAC scores were significantly improved at 1 year (P<0.0001). The Knee-Plan system can be a realistic, simple, and reliable alternative to conventional cutting guides and to computer-assisted surgery for TKA implantation. IV; prospective cohort study. Copyright © 2014. Published by Elsevier Masson SAS.
Kweon, Hyojin; Yiacoumi, Sotira Z.; Tsouris, Costas
2015-06-19
In this study, the influence of electrostatic charge on the adhesive force between spherical particles and planar surfaces in atmospheric systems was studied using atomic force microscopy. Electrical bias was applied to modify the surface charge, and it was found that application of a stronger positive bias to a particle induces a stronger total adhesive force. The sensitivity of the system to changes in the bias depended on the surface charge density. For larger-size particles, the contribution of the electrostatic force decreased, and the capillary force became the major contributor to the total adhesive force. The influence of water adsorptionmore » on the total adhesive force and, specifically, on the contribution of the electrostatic force depended on the hydrophobicity of interacting surfaces. For a hydrophilic surface, water adsorption either attenuated the surface charge or screened the effect of surface potential. An excessive amount of adsorbed water provided a path to surface charge leakage, which might cancel out the electrostatic force, leading to a reduction in the adhesive force. Theoretically calculated forces were comparable with measured adhesive forces except for mica which has a highly localized surface potential. The results of this study provide information on the behavior of charged colloidal particles in atmospheric systems.« less
Huston, R; Chan, Y C; Chapman, H; Gardner, T; Shaw, G
2012-03-15
Due to prolonged droughts in recent years, the use of rainwater tanks in urban areas has increased in Australia. In order to apportion sources of contribution to heavy metal and ionic contaminants in rainwater tanks in Brisbane, a subtropical urban area in Australia, monthly tank water samples (24 sites, 31 tanks) and concurrent bulk deposition samples (18 sites) were collected during mainly April 2007-March 2008. The samples were analysed for acid-soluble metals, soluble anions, total inorganic carbon and total organic carbon, and characteristics such as total solid and pH. The Positive Matrix Factorisation model, EPA PMF 3.0, was used to apportion sources of contribution to the contaminants. Four source factors were identified for the bulk deposition samples, including 'crustal matter/sea salt', 'car exhausts/road side dust', 'industrial dust' and 'aged sea salt/secondary aerosols'. For the tank water samples, apart from these atmospheric deposition related factors which contributed in total to 65% of the total contaminant concentration on average, another six rainwater collection system related factors were identified, including 'plumbing', 'building material', 'galvanizing', 'roofing', 'steel' and 'lead flashing/paint' (contributing in total to 35% of the total concentration on average). The Australian Drinking Water Guideline for lead was exceeded in 15% of the tank water samples. The collection system related factors, in particular the 'lead flashing/paint' factor, contributed to 79% of the lead in the tank water samples on average. The concentration of lead in tank water was found to vary with various environmental and collection system factors, in particular the presence of lead flashing on the roof. The results also indicated the important role of sludge dynamics inside the tank on the quality of tank water. Copyright © 2011 Elsevier Ltd. All rights reserved.
2012-01-01
Background No previous studies have addressed the integrated relationships among system quality, service quality, job satisfaction, and system performance; this study attempts to bridge such a gap with evidence-based practice study. Methods The convenience sampling method was applied to the information system users of three hospitals in southern Taiwan. A total of 500 copies of questionnaires were distributed, and 283 returned copies were valid, suggesting a valid response rate of 56.6%. SPSS 17.0 and AMOS 17.0 (structural equation modeling) statistical software packages were used for data analysis and processing. Results The findings are as follows: System quality has a positive influence on service quality (γ11= 0.55), job satisfaction (γ21= 0.32), and system performance (γ31= 0.47). Service quality (β31= 0.38) and job satisfaction (β32= 0.46) will positively influence system performance. Conclusions It is thus recommended that the information office of hospitals and developers take enhancement of service quality and user satisfaction into consideration in addition to placing b on system quality and information quality when designing, developing, or purchasing an information system, in order to improve benefits and gain more achievements generated by hospital information systems. PMID:23171394
Maheswaran, Hendramoorthy; Petrou, Stavros; Cohen, Danielle; MacPherson, Peter; Kumwenda, Felistas; Lalloo, David G; Corbett, Elizabeth L; Clarke, Aileen
2018-01-01
Although HIV infection and its associated co-morbidities remain the commonest reason for hospitalisation in Africa, their impact on economic costs and health-related quality of life (HRQoL) are not well understood. This information is essential for decision-makers to make informed choices about how to best scale-up anti-retroviral treatment (ART) programmes. This study aimed to quantify the impact of HIV infection and ART on economic outcomes in a prospective cohort of hospitalised patients with high HIV prevalence. Sequential medical admissions to Queen Elizabeth Central Hospital, Malawi, between June-December 2014 were followed until discharge, with standardised classification of medical diagnosis and estimation of healthcare resources used. Primary costing studies estimated total health provider cost by medical diagnosis. Participants were interviewed to establish direct non-medical and indirect costs. Costs were adjusted to 2014 US$ and INT$. HRQoL was measured using the EuroQol EQ-5D. Multivariable analyses estimated predictors of economic outcomes. Of 892 eligible participants, 80.4% (647/892) were recruited and medical notes found. In total, 447/647 (69.1%) participants were HIV-positive, 339/447 (75.8%) were on ART prior to admission, and 134/647 (20.7%) died in hospital. Mean duration of admission for HIV-positive participants not on ART and HIV-positive participants on ART was 15.0 days (95%CI: 12.0-18.0) and 12.2 days (95%CI: 10.8-13.7) respectively, compared to 10.8 days (95%CI: 8.8-12.8) for HIV-negative participants. Mean total provider cost per hospital admission was US$74.78 (bootstrap 95%CI: US$25.41-US$124.15) higher for HIV-positive than HIV-negative participants. Amongst HIV-positive participants, the mean total provider cost was US$106.87 (bootstrap 95%CI: US$25.09-US$106.87) lower for those on ART than for those not on ART. The mean total direct non-medical and indirect cost per hospital admission was US$87.84. EQ-5D utility scores were lower amongst HIV-positive participants, but not significantly different between those on and not on ART. HIV-related hospital care poses substantial financial burdens on health systems and patients; however, per-admission costs are substantially lower for those already initiated onto ART prior to admission. These potential cost savings could offset some of the additional resources needed to provide universal access to ART.
Petrou, Stavros; Cohen, Danielle; MacPherson, Peter; Kumwenda, Felistas; Lalloo, David G.; Corbett, Elizabeth L.; Clarke, Aileen
2018-01-01
Introduction Although HIV infection and its associated co-morbidities remain the commonest reason for hospitalisation in Africa, their impact on economic costs and health-related quality of life (HRQoL) are not well understood. This information is essential for decision-makers to make informed choices about how to best scale-up anti-retroviral treatment (ART) programmes. This study aimed to quantify the impact of HIV infection and ART on economic outcomes in a prospective cohort of hospitalised patients with high HIV prevalence. Methods Sequential medical admissions to Queen Elizabeth Central Hospital, Malawi, between June-December 2014 were followed until discharge, with standardised classification of medical diagnosis and estimation of healthcare resources used. Primary costing studies estimated total health provider cost by medical diagnosis. Participants were interviewed to establish direct non-medical and indirect costs. Costs were adjusted to 2014 US$ and INT$. HRQoL was measured using the EuroQol EQ-5D. Multivariable analyses estimated predictors of economic outcomes. Results Of 892 eligible participants, 80.4% (647/892) were recruited and medical notes found. In total, 447/647 (69.1%) participants were HIV-positive, 339/447 (75.8%) were on ART prior to admission, and 134/647 (20.7%) died in hospital. Mean duration of admission for HIV-positive participants not on ART and HIV-positive participants on ART was 15.0 days (95%CI: 12.0–18.0) and 12.2 days (95%CI: 10.8–13.7) respectively, compared to 10.8 days (95%CI: 8.8–12.8) for HIV-negative participants. Mean total provider cost per hospital admission was US$74.78 (bootstrap 95%CI: US$25.41-US$124.15) higher for HIV-positive than HIV-negative participants. Amongst HIV-positive participants, the mean total provider cost was US$106.87 (bootstrap 95%CI: US$25.09-US$106.87) lower for those on ART than for those not on ART. The mean total direct non-medical and indirect cost per hospital admission was US$87.84. EQ-5D utility scores were lower amongst HIV-positive participants, but not significantly different between those on and not on ART. Conclusions HIV-related hospital care poses substantial financial burdens on health systems and patients; however, per-admission costs are substantially lower for those already initiated onto ART prior to admission. These potential cost savings could offset some of the additional resources needed to provide universal access to ART. PMID:29543818
Mockup Small-Diameter Air Distribution System
DOE Office of Scientific and Technical Information (OSTI.GOV)
A. Poerschke and A. Rudd
2016-05-01
This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses anmore » additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.« less
Guo, Yawen; Jiang, Qingwu; Tanimoto, Tetsuya; Kami, Masahiro; Luo, Chunyan; Leppold, Claire; Nishimura, Koichi; He, Yongpin; Kato, Shigeaki; Ding, Xiaocang
2017-04-01
Significant prevalence rates of adolescent scoliosis in China were suggested in previous studies. However, school screenings for adolescent scoliosis have been suspended due to low rates of positive detection under the past screening system in China. The present study was undertaken to screen for adolescent scoliosis in middle school students under a modern assessment system in a district of Shanghai. We performed a population-based, cross-sectional study of a middle school scoliosis screening program in the Jingan district. In 2015, schoolchildren were initially screened by visual inspection of clinical signs and the forward-bending test. Suspected cases were referred for radiography in hospital for scoliosis diagnosis. A total of 5327 middle school students (grades 6-8) were screened with 520 (9.76%) positives (the positive rates of girls and boys at 15.28% and 4.59%, respectively) and no statistically significant difference among grades. Only 301 positives (57.9%) followed the referral for hospital radiography. There were 102 cases (33.9%) that were diagnosed with scoliosis by radiography criteria (Cobb angle ≥10°) including mild scoliosis (Cobb 10-25) for 94 cases and moderate scoliosis (Cobb 25-40) for 8 cases, and false-positives (Cobb 0) for 39 cases. The putative prevalence rate was estimated as 1.9% from the referred students. Under an accurate and modern assessment system, school screenings can detect scoliosis at a significant rate, but awareness of scoliosis risks is needed for residents in China to take up referrals for hospital diagnosis after school screenings.
Impact of non-integer planetary revolutions on the distribution of evaporated optical coatings
Oliver, J. B.
2017-02-08
Planetary substrate rotation for optical-coating deposition is evaluated based on initial and final positions for a given layer with different numbers of revolutions and various deposition-source locations. The influence of partial revolutions of the rotation system is analyzed relative to the total number of planetary revolutions in that layer to determine the relative impact on film thickness and uniformity. Furthermore, guidance is provided on the necessary planetary revolutions that should take place in each layer versus the expected error level in the layer thickness for the modeled system.
Ryan, M.J.
1987-05-04
A steam trap monitor positioned downstream of a steam trap in a closed steam system includes a first sensor (a hot finger) for measuring the energy of condensate and a second sensor (a cold finger) for measuring the total energy of condensate and steam in the line. The hot finger includes one or more thermocouples for detecting condensate level and energy, while the cold finger contains a liquid with a lower boiling temperature than that of water. Vapor pressure from the liquid is used to do work such as displacing a piston or bellow in providing an indication of total energy (steam + condensate) of the system. Processing means coupled to and responsive to outputs from the hot and cold fingers subtracts the former from the latter to provide an indication of the presence of steam downstream from the trap indicating that the steam trap is malfunctioning. 2 figs.
Stochastic effects in a discretized kinetic model of economic exchange
NASA Astrophysics Data System (ADS)
Bertotti, M. L.; Chattopadhyay, A. K.; Modanese, G.
2017-04-01
Linear stochastic models and discretized kinetic theory are two complementary analytical techniques used for the investigation of complex systems of economic interactions. The former employ Langevin equations, with an emphasis on stock trade; the latter is based on systems of ordinary differential equations and is better suited for the description of binary interactions, taxation and welfare redistribution. We propose a new framework which establishes a connection between the two approaches by introducing random fluctuations into the kinetic model based on Langevin and Fokker-Planck formalisms. Numerical simulations of the resulting model indicate positive correlations between the Gini index and the total wealth, that suggest a growing inequality with increasing income. Further analysis shows, in the presence of a conserved total wealth, a simultaneous decrease in inequality as social mobility increases, in conformity with economic data.
Cardiopulmonary responses to acute hypoxia, head-down tilt and fluid loading in anesthetized dogs
NASA Technical Reports Server (NTRS)
Loeppky, J. A.; Scotto, P.; Riedel, C.; Avasthi, P.; Koshukosky, V.; Chick, T. W.
1991-01-01
Cardiopulmonary responses to acute hypoxia (HY), fluid loading by saline infusion (FL), and head-down tilt (HD) of mechanically ventilated anesthetized dogs were investigated by measuring thermodynamics and pulmonary gas exchange. It was found that HD decreased the total respiratory compliance both during HY and normoxia (NO) and that the reduction in compliance by FL was twice as large as by HD. Superimposing HD on HY doubled the increase in vascular resistance due to HY alone. In the systemic circulation, HD lowered the resistance to below NO levels. There was a significant positive correlation between the changes in blood volume and in pulmonary artery pressure for experimental transitions, suggesting that a shift in blood volume from systemic to pulmonary circulations and changes in the total blood volume may contribute substantially to these apparent changes in resistance.
Radio-Optical Reference Frame Link Using the U.S. Naval Observatory Astrograph and Deep CCD Imaging
NASA Astrophysics Data System (ADS)
Zacharias, N.; Zacharias, M. I.
2014-05-01
Between 1997 and 2004 several observing runs were conducted, mainly with the CTIO 0.9 m, to image International Celestial Reference Frame (ICRF) counterparts (mostly QSOs) in order to determine accurate optical positions. Contemporary to these deep CCD images, the same fields were observed with the U.S. Naval Observatory astrograph in the same bandpass. They provide accurate positions on the Hipparcos/Tycho-2 system for stars in the 10-16 mag range used as reference stars for the deep CCD imaging data. Here we present final optical position results of 413 sources based on reference stars obtained by dedicated astrograph observations that were reduced following two different procedures. These optical positions are compared to radio very long baseline interferometry positions. The current optical system is not perfectly aligned to the ICRF radio system with rigid body rotation angles of 3-5 mas (= 3σ level) found between them for all three axes. Furthermore, statistically, the optical-radio position differences are found to exceed the total, combined, known errors in the observations. Systematic errors in the optical reference star positions and physical offsets between the centers of optical and radio emissions are both identified as likely causes. A detrimental, astrophysical, random noise component is postulated to be on about the 10 mas level. If confirmed by future observations, this could severely limit the Gaia to ICRF reference frame alignment accuracy to an error of about 0.5 mas per coordinate axis with the current number of sources envisioned to provide the link. A list of 36 ICRF sources without the detection of an optical counterpart to a limiting magnitude of about R = 22 is provided as well.
Radio-optical reference frame link using the U.S. Naval observatory astrograph and deep CCD imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zacharias, N.; Zacharias, M. I., E-mail: nz@usno.navy.mil
2014-05-01
Between 1997 and 2004 several observing runs were conducted, mainly with the CTIO 0.9 m, to image International Celestial Reference Frame (ICRF) counterparts (mostly QSOs) in order to determine accurate optical positions. Contemporary to these deep CCD images, the same fields were observed with the U.S. Naval Observatory astrograph in the same bandpass. They provide accurate positions on the Hipparcos/Tycho-2 system for stars in the 10-16 mag range used as reference stars for the deep CCD imaging data. Here we present final optical position results of 413 sources based on reference stars obtained by dedicated astrograph observations that were reducedmore » following two different procedures. These optical positions are compared to radio very long baseline interferometry positions. The current optical system is not perfectly aligned to the ICRF radio system with rigid body rotation angles of 3-5 mas (= 3σ level) found between them for all three axes. Furthermore, statistically, the optical-radio position differences are found to exceed the total, combined, known errors in the observations. Systematic errors in the optical reference star positions and physical offsets between the centers of optical and radio emissions are both identified as likely causes. A detrimental, astrophysical, random noise component is postulated to be on about the 10 mas level. If confirmed by future observations, this could severely limit the Gaia to ICRF reference frame alignment accuracy to an error of about 0.5 mas per coordinate axis with the current number of sources envisioned to provide the link. A list of 36 ICRF sources without the detection of an optical counterpart to a limiting magnitude of about R = 22 is provided as well.« less
Varnes, David J.; Coe, J.A.; Godt, J.W.; Savage, W.Z.; Savage, J.E.
2000-01-01
Measurements of ridge-spreading movements at Bald Eagle Mountain in north-central Colorado were reported in USGS Open-File Report 90-543 for the years 1975-1989. Measurements were renewed in 1997 and 1999 using the Global Positioning System (GPS). Movements are generally away from a ridge-top graben and appear to be concentrated along 3 or 4 trenches with uphill facing scarps that are parallel with slope contours. A point just below the lowest trench has moved the most? a total of 8.3 cm horizontally and slightly downward from 1977 to 1999 relative to an assumed stable point on the periphery of the graben. Movements from 1997 to 1999 are less than 1 cm or within the error of measurement.
NASA Astrophysics Data System (ADS)
Pathak, P. C.; Pandey, A. N.; Singh, J. S.
1984-03-01
Overland flow, sediment output and input and output of precipitation nutrients were evaluated on six forested sites in the central Himalaya during the 1981 and 1982 monsoon seasons. Overland flow was significantly different across the forests and the months of the rainy season. It was positively related with rainfall quantity and intensity, and was negatively related with tree canopy cover and with ground vegetation cover. Average overland flow was only 0.66% of the total incident rainfall, indicating that these sites are subsurface-flow systems. Sediment output was positively related to overland flow. Rainfall added a significant amount of nutrients to the forests. This extra-system input was greater than loss through overland flow + sediment output. The loss of nutrients from the forested sites was in the order: Mg > C > Ca > K = N = P.
NASA Astrophysics Data System (ADS)
Abbaszadeh, Shiva; Chinn, Garry; Levin, Craig S.
2018-01-01
The kinematics of Compton scatter can be used to estimate the interaction sequence of inter-crystal scatter interactions in 3D position-sensitive cadmium zinc telluride (CZT) detectors. However, in the case of intra-crystal scatter in a ‘cross-strip’ CZT detector slab, multiple anode and cathode strips may be triggered, creating position ambiguity due to uncertainty in possible combinations of anode-cathode pairings. As a consequence, methods such as energy-weighted centroid are not applicable to position the interactions. In practice, since the event position is uncertain, these intra-crystal scatters events are discarded. In this work, we studied using Compton kinematics and a ‘direction difference angle’ to provide a method to correctly identify the anode-cathode pair corresponding to the first interaction position in an intra-crystal scatter event. GATE simulation studies of a NEMA NU4 image quality phantom in a small animal positron emission tomography under development composed of 192, 40~mm×40~mm×5 mm CZT crystals shows that 47% of total numbers of multiple-interaction photon events (MIPEs) are intra-crystal scatter with a 100 keV lower energy threshold per interaction. The sensitivity of the system increases from 0.6 to 4.10 (using 10 keV as system lower energy threshold) by including rather than discarding inter- and intra-crystal scatter. The contrast-to-noise ratio (CNR) also increases from 5.81+/-0.3 to 12.53+/-0.37 . It was shown that a higher energy threshold limits the capability of the system to detect MIPEs and reduces CNR. Results indicate a sensitivity increase (4.1 to 5.88) when raising the lower energy threshold (10 keV to 100 keV) for the case of only two-interaction events. In order to detect MIPEs accurately, a low noise system capable of a low energy threshold (10 keV) per interaction is desired.
Activation of normal neutrophils by anti-neutrophil cytoplasm antibodies.
Keogan, M T; Esnault, V L; Green, A J; Lockwood, C M; Brown, D L
1992-01-01
Anti-neutrophil cytoplasm antibodies (ANCA) are markers of systemic vasculitis for which a pathogenetic role has been postulated. We have examined the effect of these autoantibodies on the function of normal human neutrophils in vitro. In the presence of ANCA positive sera luminol-amplified chemiluminescence was significantly increased compared to the values seen in the presence of normal or anti-double stranded DNA positive sera (P < 0.01). Five of six ANCA positive F(ab)2 preparations also produced significant neutrophil activation as demonstrated by the chemiluminescence response. This response was totally abrogated by the addition of neutrophil cytoplasm extract, containing the ANCA antigen. Addition of inhibitors to the chemiluminescence system demonstrated that the chemiluminescence response was inhibited by azide and salicylhydroxamic acid and reduced by histidine, suggesting that the chemiluminescence response was due to activation of myeloperoxidase, with generation of singlet oxygen. The chemotactic response to f-Met-Leu-Phe, a bacterial chemotactic peptide, was significantly augmented in the presence of ANCA. Chemotaxis to zymosan-activated serum and chemokinesis was not affected. Phagocytosis was also unaffected. We propose that neutrophil activation and modulation of neutrophil migration by ANCA may be of pathogenetic significance in systemic vasculitis. PMID:1424279
NASA Technical Reports Server (NTRS)
Knox, C. E.
1978-01-01
Navigation error data from these flights are presented in a format utilizing three independent axes - horizontal, vertical, and time. The navigation position estimate error term and the autopilot flight technical error term are combined to form the total navigation error in each axis. This method of error presentation allows comparisons to be made between other 2-, 3-, or 4-D navigation systems and allows experimental or theoretical determination of the navigation error terms. Position estimate error data are presented with the navigation system position estimate based on dual DME radio updates that are smoothed with inertial velocities, dual DME radio updates that are smoothed with true airspeed and magnetic heading, and inertial velocity updates only. The normal mode of navigation with dual DME updates that are smoothed with inertial velocities resulted in a mean error of 390 m with a standard deviation of 150 m in the horizontal axis; a mean error of 1.5 m low with a standard deviation of less than 11 m in the vertical axis; and a mean error as low as 252 m with a standard deviation of 123 m in the time axis.
Li, Heng; Sahoo, Narayan; Poenisch, Falk; Suzuki, Kazumichi; Li, Yupeng; Li, Xiaoqiang; Zhang, Xiaodong; Lee, Andrew K.; Gillin, Michael T.; Zhu, X. Ronald
2013-01-01
Purpose: The purpose of this work was to assess the monitor unit (MU) values and position accuracy of spot scanning proton beams as recorded by the daily treatment logs of the treatment control system, and furthermore establish the feasibility of using the delivered spot positions and MU values to calculate and evaluate delivered doses to patients. Methods: To validate the accuracy of the recorded spot positions, the authors generated and executed a test treatment plan containing nine spot positions, to which the authors delivered ten MU each. The spot positions were measured with radiographic films and Matrixx 2D ion-chambers array placed at the isocenter plane and compared for displacements from the planned and recorded positions. Treatment logs for 14 patients were then used to determine the spot MU values and position accuracy of the scanning proton beam delivery system. Univariate analysis was used to detect any systematic error or large variation between patients, treatment dates, proton energies, gantry angles, and planned spot positions. The recorded patient spot positions and MU values were then used to replace the spot positions and MU values in the plan, and the treatment planning system was used to calculate the delivered doses to patients. The results were compared with the treatment plan. Results: Within a treatment session, spot positions were reproducible within ±0.2 mm. The spot positions measured by film agreed with the planned positions within ±1 mm and with the recorded positions within ±0.5 mm. The maximum day-to-day variation for any given spot position was within ±1 mm. For all 14 patients, with ∼1 500 000 spots recorded, the total MU accuracy was within 0.1% of the planned MU values, the mean (x, y) spot displacement from the planned value was (−0.03 mm, −0.01 mm), the maximum (x, y) displacement was (1.68 mm, 2.27 mm), and the (x, y) standard deviation was (0.26 mm, 0.42 mm). The maximum dose difference between calculated dose to the patient based on the plan and recorded data was within 2%. Conclusions: The authors have shown that the treatment log file in a spot scanning proton beam delivery system is precise enough to serve as a quality assurance tool to monitor variation in spot position and MU value, as well as the delivered dose uncertainty from the treatment delivery system. The analysis tool developed here could be useful for assessing spot position uncertainty and thus dose uncertainty for any patient receiving spot scanning proton beam therapy. PMID:23387726
Behavior of the Position-Spread Tensor in Diatomic Systems.
Brea, Oriana; El Khatib, Muammar; Angeli, Celestino; Bendazzoli, Gian Luigi; Evangelisti, Stefano; Leininger, Thierry
2013-12-10
The behavior of the Position-Spread Tensor (Λ) in a series of light diatomic molecules (either neutral or negative ions) is investigated at a Full Configuration Interaction level. This tensor, which is the second moment cumulant of the total position operator, is invariant with respect to molecular translations, while its trace is also rotationally invariant. Moreover, the tensor is additive in the case of noninteracting subsystems and can be seen as an intrinsic property of a molecule. In the present work, it is shown that the longitudinal component of the tensor, Λ∥, which is small for internuclear distances close to the equilibrium, tends to grow if the bond is stretched. A maximum is reached in the region of the bond breaking, then Λ∥ decreases and converges toward the isolated-atom value. The degenerate transversal components, Λ⊥, on the other hand, usually have a monotonic growth toward the atomic value. The Position Spread is extremely sensitive to reorganization of the molecular wave function, and it becomes larger in the case of an increase of the electron mobility, as illustrated by the neutral-ionic avoided crossing in LiF. For these reasons, the Position Spread can be an extremely useful property that characterizes the nature of the wave function in a molecular system.
Incidence of smear-positive tuberculosis in Dabat, northern Ethiopia.
Tadesse, T; Demissie, M; Berhane, Y; Kebede, Y; Abebe, M
2013-05-01
To determine the incidence of smear-positive tuberculosis (TB) in Dabat District, northern Ethiopia. Using a population-based longitudinal design, a TB surveillance system was initiated among 46,165 residents at the Dabat Health and Demographic Surveillance System site. Trained field workers visited each household every third month and interviewed all individuals aged ≥14 years using a uniform questionnaire to detect suspected cases of TB (cough ≥15 days), at which time two sputum (spot-morning) samples were collected for smear microscopy. A total of 281,820 person-months were observed during the 1-year period, which generated 74 smear-positive TB cases. The incidence of smear-positive TB was calculated at 311 per 100,000 person-years (95%CI 240-382). Higher rates were observed among females (incidence rate ratio [IRR] 2.08, 95%CI 1.24-3.52), persons with no schooling (IRR 2.74, 95%CI 1.11-6.78) and urban residents (IRR 2.39, 95%CI 1.39-4.12). The incidence of smear-positive TB is high in Dabat District, suggesting a high risk of transmission in the communities. TB control programmes thus need to improve case-finding mechanisms at the community level in Ethiopia, with greater emphasis on risk groups.
Klink, Thorsten; Geiger, Julia; Both, Marcus; Ness, Thomas; Heinzelmann, Sonja; Reinhard, Matthias; Holl-Ulrich, Konstanze; Duwendag, Dirk; Vaith, Peter; Bley, Thorsten Alexander
2014-12-01
To assess the diagnostic accuracy of contrast material-enhanced magnetic resonance (MR) imaging of superficial cranial arteries in the initial diagnosis of giant cell arteritis ( GCA giant cell arteritis ). Following institutional review board approval and informed consent, 185 patients suspected of having GCA giant cell arteritis were included in a prospective three-university medical center trial. GCA giant cell arteritis was diagnosed or excluded clinically in all patients (reference standard [final clinical diagnosis]). In 53.0% of patients (98 of 185), temporal artery biopsy ( TAB temporal artery biopsy ) was performed (diagnostic standard [ TAB temporal artery biopsy ]). Two observers independently evaluated contrast-enhanced T1-weighted MR images of superficial cranial arteries by using a four-point scale. Diagnostic accuracy, involvement pattern, and systemic corticosteroid ( sCS systemic corticosteroid ) therapy effects were assessed in comparison with the reference standard (total study cohort) and separately in comparison with the diagnostic standard TAB temporal artery biopsy ( TAB temporal artery biopsy subcohort). Statistical analysis included diagnostic accuracy parameters, interobserver agreement, and receiver operating characteristic analysis. Sensitivity of MR imaging was 78.4% and specificity was 90.4% for the total study cohort, and sensitivity was 88.7% and specificity was 75.0% for the TAB temporal artery biopsy subcohort (first observer). Diagnostic accuracy was comparable for both observers, with good interobserver agreement ( TAB temporal artery biopsy subcohort, κ = 0.718; total study cohort, κ = 0.676). MR imaging scores were significantly higher in patients with GCA giant cell arteritis -positive results than in patients with GCA giant cell arteritis -negative results ( TAB temporal artery biopsy subcohort and total study cohort, P < .001). Diagnostic accuracy of MR imaging was high in patients without and with sCS systemic corticosteroid therapy for 5 days or fewer (area under the curve, ≥0.9) and was decreased in patients receiving sCS systemic corticosteroid therapy for 6-14 days. In 56.5% of patients with TAB temporal artery biopsy -positive results (35 of 62), MR imaging displayed symmetrical and simultaneous inflammation of arterial segments. MR imaging of superficial cranial arteries is accurate in the initial diagnosis of GCA giant cell arteritis . Sensitivity probably decreases after more than 5 days of sCS systemic corticosteroid therapy; thus, imaging should not be delayed. Clinical trial registration no. DRKS00000594 . © RSNA, 2014.
A Markerless 3D Computerized Motion Capture System Incorporating a Skeleton Model for Monkeys.
Nakamura, Tomoya; Matsumoto, Jumpei; Nishimaru, Hiroshi; Bretas, Rafael Vieira; Takamura, Yusaku; Hori, Etsuro; Ono, Taketoshi; Nishijo, Hisao
2016-01-01
In this study, we propose a novel markerless motion capture system (MCS) for monkeys, in which 3D surface images of monkeys were reconstructed by integrating data from four depth cameras, and a skeleton model of the monkey was fitted onto 3D images of monkeys in each frame of the video. To validate the MCS, first, estimated 3D positions of body parts were compared between the 3D MCS-assisted estimation and manual estimation based on visual inspection when a monkey performed a shuttling behavior in which it had to avoid obstacles in various positions. The mean estimation error of the positions of body parts (3-14 cm) and of head rotation (35-43°) between the 3D MCS-assisted and manual estimation were comparable to the errors between two different experimenters performing manual estimation. Furthermore, the MCS could identify specific monkey actions, and there was no false positive nor false negative detection of actions compared with those in manual estimation. Second, to check the reproducibility of MCS-assisted estimation, the same analyses of the above experiments were repeated by a different user. The estimation errors of positions of most body parts between the two experimenters were significantly smaller in the MCS-assisted estimation than in the manual estimation. Third, effects of methamphetamine (MAP) administration on the spontaneous behaviors of four monkeys were analyzed using the MCS. MAP significantly increased head movements, tended to decrease locomotion speed, and had no significant effect on total path length. The results were comparable to previous human clinical data. Furthermore, estimated data following MAP injection (total path length, walking speed, and speed of head rotation) correlated significantly between the two experimenters in the MCS-assisted estimation (r = 0.863 to 0.999). The results suggest that the presented MCS in monkeys is useful in investigating neural mechanisms underlying various psychiatric disorders and developing pharmacological interventions.
Holm, René; Porter, Christopher J H; Müllertz, Anette; Kristensen, Henning G; Charman, William N
2002-09-01
To compare the influence of triglyceride vehicle intramolecular structure on the intestinal lymphatic transport and systemic absorption of halofantrine in conscious rats. Conscious, lymph cannulated and nonlymph cannulated rats were dosed orally with three structurally different triglycerides; sunflower oil, and two structured triglycerides containing different proportion and position of medium-(M) and long-chain (L) fatty acids on the glycerol backbone. The two structured triglycerides were abbreviated MLM and LML to reflect the structural position on the glycerol. The concentration of halofantrine in blood and lymph samples was analyzed by HPLC. Both the lymphatic transport and the total absorption of halofantrine were enhanced by the use the MLM triglyceride. The estimated total absorption of halofantrine in the lymph cannulated animals was higher than in the nonlymph cannulated animals, and this was most pronounced for the animals dosed with the structured triglycerides. Using MLM as vehicle increases the portal absorption of halofantrine and results in similar lymphatic transport levels when compared to sunflower oil. Total absorption when assessed as absorption in the blood plus lymphatic transport for halofantrine after administration in the MLM triglyceride was higher than after administration in sunflower oil.
Does a Single Eigenstate Encode the Full Hamiltonian?
NASA Astrophysics Data System (ADS)
Garrison, James R.; Grover, Tarun
2018-04-01
The eigenstate thermalization hypothesis (ETH) posits that the reduced density matrix for a subsystem corresponding to an excited eigenstate is "thermal." Here we expound on this hypothesis by asking: For which class of operators, local or nonlocal, is ETH satisfied? We show that this question is directly related to a seemingly unrelated question: Is the Hamiltonian of a system encoded within a single eigenstate? We formulate a strong form of ETH where, in the thermodynamic limit, the reduced density matrix of a subsystem corresponding to a pure, finite energy density eigenstate asymptotically becomes equal to the thermal reduced density matrix, as long as the subsystem size is much less than the total system size, irrespective of how large the subsystem is compared to any intrinsic length scale of the system. This allows one to access the properties of the underlying Hamiltonian at arbitrary energy densities (or temperatures) using just a single eigenstate. We provide support for our conjecture by performing an exact diagonalization study of a nonintegrable 1D quantum lattice model with only energy conservation. In addition, we examine the case in which the subsystem size is a finite fraction of the total system size, and we find that, even in this case, many operators continue to match their canonical expectation values, at least approximately. In particular, the von Neumann entanglement entropy equals the thermal entropy as long as the subsystem is less than half the total system. Our results are consistent with the possibility that a single eigenstate correctly predicts the expectation values of all operators with support on less than half the total system, as long as one uses a microcanonical ensemble with vanishing energy width for comparison. We also study, both analytically and numerically, a particle-number conserving model at infinite temperature that substantiates our conjectures.
Frank, A.A.
1984-07-10
A control system and method for a power delivery system, such as in an automotive vehicle, having an engine coupled to a continuously variable ratio transmission (CVT). Totally independent control of engine and transmission enable the engine to precisely follow a desired operating characteristic, such as the ideal operating line for minimum fuel consumption. CVT ratio is controlled as a function of commanded power or torque and measured load, while engine fuel requirements (e.g., throttle position) are strictly a function of measured engine speed. Fuel requirements are therefore precisely adjusted in accordance with the ideal characteristic for any load placed on the engine. 4 figs.
Hsieh, Hong-Jung; Hu, Chih-Chung; Lu, Tung-Wu; Lu, Hsuan-Lun; Kuo, Mei-Ying; Kuo, Chien-Chung; Hsu, Horng-Chaung
2016-06-07
Robot-based joint-testing systems (RJTS) can be used to perform unconstrained laxity tests, measuring the stiffness of a degree of freedom (DOF) of the joint at a fixed flexion angle while allowing the other DOFs unconstrained movement. Previous studies using the force-position hybrid (FPH) control method proposed by Fujie et al. (J Biomech Eng 115(3):211-7, 1993) focused on anterior/posterior tests. Its convergence and applicability on other clinically relevant DOFs such as valgus/varus have not been demonstrated. The current s1tudy aimed to develop a 6-DOF RJTS using an industrial robot, to propose two new force-position hybrid control methods, and to evaluate the performance of the methods and FPH in controlling the RJTS for anterior/posterior and valgus/varus laxity tests of the knee joint. An RJTS was developed using an industrial 6-DOF robot with a 6-component load-cell attached at the effector. The performances of FPH and two new control methods, namely force-position alternate control (FPA) and force-position hybrid control with force-moment control (FPHFM), for unconstrained anterior/posterior and valgus/varus laxity tests were evaluated and compared with traditional constrained tests (CT) in terms of the number of control iterations, total time and the constraining forces and moments. As opposed to CT, the other three control methods successfully reduced the constraining forces and moments for both anterior/posterior and valgus/varus tests, FPHFM being the best followed in order by FPA and FPH. FPHFM had root-mean-squared constraining forces and moments of less than 2.2 N and 0.09 Nm, respectively at 0° flexion, and 2.3 N and 0.14 Nm at 30° flexion. The corresponding values for FPH were 8.5 N and 0.33 Nm, and 11.5 N and 0.45 Nm, respectively. Given the same control parameters including the compliance matrix, FPHFM and FPA reduced the constraining loads of FPH at the expense of additional control iterations, and thus increased total time, FPA taking about 10 % longer than FPHFM. The FPHFM would be the best choice among the methods considered when longer total time is acceptable in the intended clinical applications. The current results will be useful for selecting a force-position hybrid control method for unconstrained laxity tests using an RJTS.
Pipes, W O; Minnigh, H A; Moyer, B; Troy, M A
1986-01-01
A total of 2,601 water samples from six different water systems were tested for coliform bacteria by Clark's presence-absence (P-A) test and by the membrane filter (MF) method. There was no significant difference in the fraction of samples positive for coliform bacteria for any of the systems tested. It was concluded that the two tests are equivalent for monitoring purposes. However, 152 samples were positive for coliform bacteria by the MF method but negative by the P-A test, and 132 samples were positive by the P-A test but negative by the MF method. Many of these differences for individual samples can be explained by random dispersion of bacteria in subsamples when the coliform density is low. However, 15 samples had MF counts greater than 3 and gave negative P-A results. The only apparent explanation for most of these results is that coliform bacteria were present in the P-A test bottles but did not produce acid and gas. Two other studies have reported more samples positive by Clark's P-A test than by the MF method. PMID:3532953
Bush, Michael; Barnes, Chris; Archer, David T; Hogg, Bob; Bradley, Paul S
2015-02-01
This study aimed to investigate position-specific evolution of physical and technical performance parameters in the English Premier League (EPL). Match performance observations (n=14700) were collected using a multiple-camera computerized tracking system across seven seasons (2006-07 to 2012-13). Data were analyzed relative to five playing positions: central defenders (n=3792), full backs (n=3420), central midfielders (n=3200), wide midfielders (n=2136) and attackers (n=2152). High-intensity running distance increased in the final season versus the first season in all playing positions (p<.05, ES: 0.9-1.3) with full backs displaying the greatest increase (∼36% higher in 2012-13). Similar trends were observed for sprint distance with full backs demonstrating the most pronounced increase across the seven seasons (36-63%, p<.001, ES: 0.8-1.3). Central players (central defenders and midfielders) illustrated the most pronounced increases in total passes and pass success rate (p<.05, ES: 0.7-0.9) whilst wide players (full backs and wide midfielders) demonstrated only small-moderate increases in total passes and pass success rate (p<.05, ES: 0.6-0.8). The data demonstrates that evolving tactics in the EPL have impacted on the physical demands of wide players and the technical requirements of central players. These findings could be used for talent identification or position-specific physical and technical training. Copyright © 2014 Elsevier B.V. All rights reserved.
Assessing the performance of freestanding hospitals.
McCue, Michael J; Diana, Mark L
2007-01-01
Freestanding hospitals are becoming less common as more hospitals are joining or establishing relationships with multihospital systems. These associations are driven by factors, such as unrelenting competition in local markets, aging physical plants, increasing labor costs, and higher physician fees, that place a high demand on financial assets. Despite these factors, many freestanding hospitals continue to do well financially, showing increases in total profit margins and total cash flow margins. This article examines which market, management, financial, and mission factors are associated with freestanding hospitals with consistently positive cash flows, relative to those without consistently positive cash flows. The study sample consisted of freestanding, nonfederal, short-term, acute care general hospitals with more than 50 beds and three years of annual cash flow data. Data were taken from the annual surveys of the American Hospital Association, the cost reports of the Centers for Medicare and Medicaid Services, and the Area Resource File of the Health Resources and Services Administration. The data were analyzed using logistic regression to identify those factors associated with a consistently positive cash flow. Freestanding hospitals with positive cash flows were found to have a greater market share and to be located in markets with a higher number of physicians and fewer acute care beds; to have fewer unoccupied beds, higher net revenues, greater liquidity, and less debt on hand; and to treat fewer Medicare patients than those without a positive cash flow. The findings suggest that these hospitals are located in resource-rich environments and that they have strong management teams.
Formal Verification of Safety Buffers for Sate-Based Conflict Detection and Resolution
NASA Technical Reports Server (NTRS)
Herencia-Zapana, Heber; Jeannin, Jean-Baptiste; Munoz, Cesar A.
2010-01-01
The information provided by global positioning systems is never totally exact, and there are always errors when measuring position and velocity of moving objects such as aircraft. This paper studies the effects of these errors in the actual separation of aircraft in the context of state-based conflict detection and resolution. Assuming that the state information is uncertain but that bounds on the errors are known, this paper provides an analytical definition of a safety buffer and sufficient conditions under which this buffer guarantees that actual conflicts are detected and solved. The results are presented as theorems, which were formally proven using a mechanical theorem prover.
Variability in EIT Images of Lung Ventilation as a Function of Electrode Planes and Body Positions
Zhang, Jie; Patterson, Robert
2014-01-01
This study is aimed at investigating the variability in resistivity changes in the lung region as a function of air volume, electrode plane and body position. Six normal subjects (33.8 ± 4.7 years, range from 26 to 37 years) were studied using the Sheffield Electrical Impedance Tomography (EIT) portable system. Three transverse planes at the level of second intercostal space, the level of the xiphisternal joint, and midway between upper and lower locations were chosen for measurements. For each plane, sixteen electrodes were uniformly positioned around the thorax. Data were collected with the breath held at end expiration and after inspiring 0.5, 1.0, or 1.5 liters of air from end expiration, with the subject in both the supine and sitting position. The average resistivity change in five regions, two 8x8 pixel local regions in the right lung, entire right, entire left and total lung regions, were calculated. The results show the resistivity change averaged over electrode positions and subject positions was 7-9% per liter of air, with a slightly larger resistivity change of 10 % per liter air in the lower electrode plane. There was no significant difference (p>0.05) between supine and sitting. The two 8x8 regions show a larger inter individual variability (coefficient of variation, CV, is from 30% to 382%) compared to the entire left, entire right and total lung (CV is from 11% to 51%). The results for the global regions are more consistent. The large inter individual variability appears to be a problem for clinical applications of EIT, such as regional ventilation. The variability may be mitigated by choosing appropriate electrode plane, body position and region of interest for the analysis. PMID:25110529
Accuracy of BRT and Delvotest microbial inhibition tests as affected by composition of ewe's milk.
Althaus, Rafael; Torres, Antonio; Peris, Cristofol; Beltran, M Carmen; Fernandez, Nemesio; Molina, M Pilar
2003-03-01
The presence of drug residues in ewe's milk samples can be determined by microbial assays. The main limitation of these tests is the large number of false-positive results associated with them. False-positive results can be explained by the interaction of certain substances naturally existing in ewe's milk with the growth of the microorganism used in the test. In this study, milk chemical composition (fat, protein, lactose, total solids), somatic cell counts (SCCs), free fatty acid concentrations, and lactoperoxidase system components were determined in order to investigate their influence on the rate of false-positive results for the BRT and Delvotest microbiological inhibitor tests. Milk samples were obtained after morning milking of Manchega ewes at 15, 30, 45, 60, 75, 90, 105, 120, and 135 days after parturition. The animals did not receive any kind of treatment or medicated feed throughout the experiment. The false-positive rates for BRT and Delvotest were 3.75 and 2.4%, respectively. When the logistic regression model was applied, the percentages of total solids for positive samples were significantly different from those for negative samples (16.90 versus 18.42% for BRT, 16.05 versus 18.45% for Delvotest), while the SCC logarithmic transformation was significantly higher for the positive samples than for the negative samples (5.38 versus 5.11 log units for BRT, 5.32 versus 5.11 log units for Delvotest). Moreover, Delvotest-positive samples exhibited thiocyanate concentrations higher than those of Delvotest-negative samples (8.18 mg/liter versus 6.85 mg/liter). Further analyses are needed to confirm the possible presence of antimicrobial residues in this particular type of milk sample.
Berhouet, Julien; Kontaxis, Andreas; Gulotta, Lawrence V; Craig, Edward; Warren, Russel; Dines, Joshua; Dines, David
2015-04-01
Recent shoulder prostheses have introduced a concept of a universal humeral stem component platform that has an onlay humeral tray for the reverse total shoulder arthroplasty (RTSA). No studies have reported how humeral tray positioning can affect the biomechanics of RTSA. The Newcastle Shoulder Model was used to investigate the biomechanical effect of humeral tray positioning in the Biomet Comprehensive Total Shoulder System (Biomet, Warsaw, IN, USA) RTSA. Five humeral tray configuration positions were tested: no offset, and 5 mm offset in the anterior, posterior, medial, and lateral positions. Superior and inferior impingement were evaluated for abduction, scapular plane elevation, forward flexion, and external/internal rotation with the elbow at the side (adduction) and at 90° of shoulder abduction. Muscle lengths and moment arms (elevating and rotational) were calculated for the deltoid, the infraspinatus, the teres minor, and the subscapularis. Inferior impingement was not affected by the humeral tray position. There was less superior impingement during abduction, scapular plane elevation, and rotation with the shoulder when the tray was placed laterally or posteriorly. The subscapularis rotational moment arm was increased with a posterior offset, whereas infraspinatus and teres minor rotational moment arms were increased with an anterior offset. Very little change was observed for the deltoid elevating moment arm or for its muscle length. Positioning the humeral tray with posterior offset offers a biomechanical advantage for patients needing RTSA by decreasing superior impingement and increasing the internal rotational moment arm of the subscapularis, without creating inferior impingement. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Variability in EIT Images of Lung Ventilation as a Function of Electrode Planes and Body Positions.
Zhang, Jie; Patterson, Robert
2014-01-01
This study is aimed at investigating the variability in resistivity changes in the lung region as a function of air volume, electrode plane and body position. Six normal subjects (33.8 ± 4.7 years, range from 26 to 37 years) were studied using the Sheffield Electrical Impedance Tomography (EIT) portable system. Three transverse planes at the level of second intercostal space, the level of the xiphisternal joint, and midway between upper and lower locations were chosen for measurements. For each plane, sixteen electrodes were uniformly positioned around the thorax. Data were collected with the breath held at end expiration and after inspiring 0.5, 1.0, or 1.5 liters of air from end expiration, with the subject in both the supine and sitting position. The average resistivity change in five regions, two 8x8 pixel local regions in the right lung, entire right, entire left and total lung regions, were calculated. The results show the resistivity change averaged over electrode positions and subject positions was 7-9% per liter of air, with a slightly larger resistivity change of 10 % per liter air in the lower electrode plane. There was no significant difference (p>0.05) between supine and sitting. The two 8x8 regions show a larger inter individual variability (coefficient of variation, CV, is from 30% to 382%) compared to the entire left, entire right and total lung (CV is from 11% to 51%). The results for the global regions are more consistent. The large inter individual variability appears to be a problem for clinical applications of EIT, such as regional ventilation. The variability may be mitigated by choosing appropriate electrode plane, body position and region of interest for the analysis.
Segmented amplifier configurations for laser amplifier
Hagen, Wilhelm F.
1979-01-01
An amplifier system for high power lasers, the system comprising a compact array of segments which (1) preserves high, large signal gain with improved pumping efficiency and (2) allows the total amplifier length to be shortened by as much as one order of magnitude. The system uses a three dimensional array of segments, with the plane of each segment being oriented at substantially the amplifier medium Brewster angle relative to the incident laser beam and with one or more linear arrays of flashlamps positioned between adjacent rows of amplifier segments, with the plane of the linear array of flashlamps being substantially parallel to the beam propagation direction.
System and method for bidirectional flow and controlling fluid flow in a conduit
Ortiz, Marcos German
1999-01-01
A system for measuring bidirectional flow, including backflow, of fluid in a conduit. The system utilizes a structural mechanism to create a pressure differential in the conduit. Pressure sensors are positioned upstream from the mechanism, at the mechanism, and downstream from the mechanism. Data from the pressure sensors are transmitted to a microprocessor or computer, and pressure differential detected between the pressure sensors is then used to calculate the backflow. Control signals may then be generated by the microprocessor or computer to shut off valves located in the conduit, upon the occurrence of backflow, or to control flow, total material dispersed, etc. in the conduit.
Pink-Beam, Highly-Accurate Compact Water Cooled Slits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyndaker, Aaron; Deyhim, Alex; Jayne, Richard
2007-01-19
Advanced Design Consulting, Inc. (ADC) has designed accurate compact slits for applications where high precision is required. The system consists of vertical and horizontal slit mechanisms, a vacuum vessel which houses them, water cooling lines with vacuum guards connected to the individual blades, stepper motors with linear encoders, limit (home position) switches and electrical connections including internal wiring for a drain current measurement system. The total slit size is adjustable from 0 to 15 mm both vertically and horizontally. Each of the four blades are individually controlled and motorized. In this paper, a summary of the design and Finite Elementmore » Analysis of the system are presented.« less
Stenlöf, Kaj; Wernstedt, Ingrid; Fjällman, Ted; Wallenius, Ville; Wallenius, Kristina; Jansson, John-Olov
2003-09-01
Recently, we demonstrated that intracerebroventricular injection of IL-6 increases energy expenditure and decreases body fat in rodents. Therefore, IL-6 may play a role in appetite and body weight control in the central nervous system. In the present study we evaluated cerebrospinal fluid (CSF) and serum IL-6 levels in humans in relation to body fat content and to CSF and serum levels of leptin. Thirty-two healthy overweight/obese male subjects with a body mass index range of 29.3-36.0 kg/m(2) were studied. Total and sc body fat were measured by dual energy x-ray absorptiometry and computed tomography, respectively. CSF IL-6 levels were in some individuals higher than serum IL-6 levels and correlated negatively with total body weight, sc and total body fat. In contrast, CSF leptin levels were 30-60 times lower than serum leptin levels and correlated positively with serum leptin, body weight, sc and total body fat. Furthermore, there was a negative correlation between CSF IL-6 and leptin. In conclusion, CSF IL-6 differs in many ways from CSF leptin. CSF IL-6 may be locally produced rather than serum derived, and body fat-regulating regions in the central nervous system may be exposed to insufficient IL-6 levels in more severe obesity.
Scott, Daniel B; Van Dyke, Michele I; Anderson, William B; Huck, Peter M
2015-12-01
The potential for regrowth of nitrifying microorganisms was monitored in 2 full-scale chloraminated drinking water distribution systems in Ontario, Canada, over a 9-month period. Quantitative PCR was used to measure amoA genes from ammonia-oxidizing bacteria (AOB) and ammonia-oxidizing archaea (AOA), and these values were compared with water quality parameters that can influence nitrifier survival and growth, including total chlorine, ammonia, temperature, pH, and organic carbon. Although there were no severe nitrification episodes, AOB and AOA were frequently detected at low concentrations in samples collected from both distribution systems. A culture-based presence-absence test confirmed the presence of viable nitrifiers. AOB were usually present in similar or greater numbers than AOA in both systems. As well, AOB showed higher regrowth potential compared with AOA in both systems. Statistically significant correlations were measured between several water quality parameters of relevance to nitrification. Total chlorine was negatively correlated with both nitrifiers and heterotrophic plate count (HPC) bacteria, and ammonia levels were positively correlated with nitrifiers. Of particular importance was the strong correlation between HPC and AOB, which reinforced the usefulness of HPC as an operational parameter to measure general microbiological conditions in distribution systems.
Pickett, William; Kukaswadia, Atif; Thompson, Wendy; Frechette, Mylene; McFaull, Steven; Dowdall, Hilary; Brison, Robert J
2014-01-01
This study assessed the use and clinical yield of diagnostic imaging (radiography, computed tomography, and medical resonance imaging) ordered to assist in the diagnosis of acute neck injuries presenting to emergency departments (EDs) in Kingston, Ontario, from 2002-2003 to 2009-2010. Acute neck injury cases were identified using records from the Kingston sites of the Canadian National Ambulatory Care Reporting System. Use of radiography was analyzed over time and related to proportions of cases diagnosed with clinically significant cervical spine injuries. A total of 4,712 neck injury cases were identified. Proportions of cases referred for diagnostic imaging to the neck varied significantly over time, from 30.4% in 2002-2003 to 37.6% in 2009-2010 (ptrend = 0.02). The percentage of total cases that were positive for clinically significant cervical spine injury ("clinical yield") also varied from a low of 5.8% in 2005-2006 to 9.2% in 2008-2009 (ptrend = 0.04), although the clinical yield of neck-imaged cases did not increase across the study years (ptrend = 0.23). Increased clinical yield was not observed in association with higher neck imaging rates whether that yield was expressed as a percentage of total cases positive for clinically significant injury (p = 0.29) or as a percentage of neck-imaged cases that were positive (p = 0.77). We observed increases in the use of diagnostic images over time, reflecting a need to reinforce an existing clinical decision rule for cervical spine radiography. Temporal increases in the clinical yield for total cases may suggest a changing case mix or more judicious use of advanced types of diagnostic imaging.
Social Media and Total Joint Arthroplasty: An Analysis of Patient Utilization on Instagram.
Ramkumar, Prem N; Navarro, Sergio M; Haeberle, Heather S; Chughtai, Morad; Flynn, Megan E; Mont, Michael A
2017-09-01
The purpose of this study was to analyze the nature of shared content of total joint arthroplasty patients on Instagram. Specifically, we evaluated social media posts for: (1) perspective and timing; (2) tone; (3) focus (activities of daily living [ADLs], rehabilitation, return-to-work); and (4) the comparison between hip and knee arthroplasties. A search of the public Instagram domain was performed over a 6-month period. Total hip and knee arthroplasties (THA and TKA) were selected for the analysis using the following terms: "#totalhipreplacement," "#totalkneereplacement," and associated terms. 1287 individual public posts of human subjects were shared during the period. A categorical scoring system was utilized for media format (photo or video), time (preoperative, perioperative, or postoperative) period, tone (positive or negative), return-to-work, ADLs, rehabilitation, surgical site, radiograph image, satisfaction, and dissatisfaction. Ninety-one percent of the posts were shared during the postoperative period. Ninety-three percent of posts had a positive tone. Thirty-four percent of posts focused on both ADLs and 33.8% on rehabilitation. TKA patients shared more about their surgical site (14.5% vs 3.3%, P < .001) and rehabilitation (58.9% vs 8.8%, P < .001) than THA patients, whereas THA patients shared more about ADLs than TKA patients (60.5% vs 7.6%, P < .001). When sharing their experience on Instagram, arthroplasty patients did so with a positive tone, starting a week after surgery. TKA posts focused more on rehabilitation and wound healing than THA patients, whereas THA patients shared more posts on ADLs. The analysis of social media posts provides insight into what matters to patients after total joint arthroplasty. Copyright © 2017 Elsevier Inc. All rights reserved.
Preliminary Design of Nano Satellite for Regional Navigation System
NASA Astrophysics Data System (ADS)
Fathurrohim, L.; Poetro, R. E.; Kurniadi, B.; Fadillah, P. A.; Iqbal, M.
2018-04-01
A Low cost Regional Navigation Satellite System employing constellation of nano satellites has been proposed for Indonesian coverage. The constellation of Low Earth Orbit nano satellites off course will not be able to give better position fixed to the GPS. However, the design of navigation system has much lower in cost compare to the current navigation system. This paper tells about preliminary design of the proposed regional navigation satellite system. The results of our satellite design has 3 kg on its weight, 10 W on power requirement at the peak condition, and 2.7 years of lifetime. Payload communication of the satellite will use UHF and TT&C communication will use VHF. Total area of solar panel will be 0.11 m2.
Laser illuminator and optical system for disk patterning
Hackel, Lloyd A.; Dane, C. Brent; Dixit, Shamasundar N.; Everett, Mathew; Honig, John
2000-01-01
Magnetic recording media are textured over areas designated for contact in order to minimize friction with data transducing heads. In fabricating a hard disk, an aluminum nickel-phosphorous substrate is polished to a specular finish. A mechanical means is then used to roughen an annular area intended to be the head contact band. An optical and mechanical system allows thousands of spots to be generated with each laser pulse, allowing the textured pattern to be rapidly generated with a low repetition rate laser and an uncomplicated mechanical system. The system uses a low power laser, a beam expander, a specially designed phase plate, a prism to deflect the beam, a lens to transmit the diffraction pattern to the far field, a mechanical means to rotate the pattern and a trigger system to fire the laser when sections of the pattern are precisely aligned. The system generates an annular segment of the desired pattern with which the total pattern is generated by rotating the optical system about its optic axis, sensing the rotational position and firing the laser as the annular segment rotates into the next appropriate position. This marking system can be integrated into a disk sputtering system for manufacturing magnetic disks, allowing for a very streamlined manufacturing process.
Exercise Performance Measurement with Smartphone Embedded Sensor for Well-Being Management
Liu, Chung-Tse; Chan, Chia-Tai
2016-01-01
Regular physical activity reduces the risk of many diseases and improves physical and mental health. However, physical inactivity is widespread globally. Improving physical activity levels is a global concern in well-being management. Exercise performance measurement systems have the potential to improve physical activity by providing feedback and motivation to users. We propose an exercise performance measurement system for well-being management that is based on the accumulated activity effective index (AAEI) and incorporates a smartphone-embedded sensor. The proposed system generates a numeric index that is based on users’ exercise performance: their level of physical activity and number of days spent exercising. The AAEI presents a clear number that can serve as a useful feedback and goal-setting tool. We implemented the exercise performance measurement system by using a smartphone and conducted experiments to assess the feasibility of the system and investigated the user experience. We recruited 17 participants for validating the feasibility of the measurement system and a total of 35 participants for investigating the user experience. The exercise performance measurement system showed an overall precision of 88% in activity level estimation. Users provided positive feedback about their experience with the exercise performance measurement system. The proposed system is feasible and has a positive effective on well-being management. PMID:27727188
Exercise Performance Measurement with Smartphone Embedded Sensor for Well-Being Management.
Liu, Chung-Tse; Chan, Chia-Tai
2016-10-11
Regular physical activity reduces the risk of many diseases and improves physical and mental health. However, physical inactivity is widespread globally. Improving physical activity levels is a global concern in well-being management. Exercise performance measurement systems have the potential to improve physical activity by providing feedback and motivation to users. We propose an exercise performance measurement system for well-being management that is based on the accumulated activity effective index (AAEI) and incorporates a smartphone-embedded sensor. The proposed system generates a numeric index that is based on users' exercise performance: their level of physical activity and number of days spent exercising. The AAEI presents a clear number that can serve as a useful feedback and goal-setting tool. We implemented the exercise performance measurement system by using a smartphone and conducted experiments to assess the feasibility of the system and investigated the user experience. We recruited 17 participants for validating the feasibility of the measurement system and a total of 35 participants for investigating the user experience. The exercise performance measurement system showed an overall precision of 88% in activity level estimation. Users provided positive feedback about their experience with the exercise performance measurement system. The proposed system is feasible and has a positive effective on well-being management.
A New Control System Software for SANS BATAN Spectrometer in Serpong, Indonesia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bharoto; Putra, Edy Giri Rachman
2010-06-22
The original main control system of the 36 meter small-angle neutron scattering (SANS) BATAN Spectrometer (SMARTer) has been replaced with the new ones due to the malfunction of the main computer. For that reason, a new control system software for handling all the control systems was also developed in order to put the spectrometer back in operation. The developed software is able to control the system such as rotation movement of six pinholes system, vertical movement of four neutron guide system with the total length of 16.5 m, two-directional movement of a neutron beam stopper, forward-backward movement of a 2Dmore » position sensitive detector (2D-PSD) along 16.7 m, etc. A Visual Basic language program running on Windows operating system was employed to develop the software and it can be operated by other remote computers in the local area network. All device positions and command menu are displayed graphically in the main monitor or window and each device control can be executed by clicking the control button. Those advantages are necessary required for developing a new user-friendly control system software. Finally, the new software has been tested for handling a complete SANS experiment and it works properly.« less
A New Control System Software for SANS BATAN Spectrometer in Serpong, Indonesia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bharoto,; Putra, Edy Giri Rachman
2010-06-22
The original main control system of the 36 meter small‐angle neutron scattering (SANS) BATAN Spectrometer (SMARTer) has been replaced with the new ones due to the malfunction of the main computer. For that reason, a new control system software for handling all the control systems was also developed in order to put the spectrometer back in operation. The developed software is able to control the system such as rotation movement of six pinholes system, vertical movement of four neutron guide system with the total length of 16.5 m, two‐directional movement of a neutron beam stopper, forward‐backward movement of a 2Dmore » position sensitive detector (2D‐PSD) along 16.7 m, etc. A Visual Basic language program running on Windows operating system was employed to develop the software and it can be operated by other remote computers in the local area network. All device positions and command menu are displayed graphically in the main monitor or window and each device control can be executed by clicking the control button. Those advantages are necessary required for developing a new user‐friendly control system software. Finally, the new software has been tested for handling a complete SANS experiment and it works properly.« less
Yao, Qi; Fan, Kai; Wang, Guo-Hong; Feng, Rui-Xiang; Liang, Yuan-Jiao; Chen, Li; Ge, Yi-Feng; Yao, Bing
2016-01-01
Objective This prospective study was designed to investigate the relationship between lipids levels in both serum and seminal plasma and semen parameters. Methods 631 subfertile men were enrolled. Their obesity-associated markers were measured, and semen parameters were analyzed. Also, seminal plasma and serum TC, TG, HDL and LDL and serum FFA, FSH, LH, total testosterone (TT), estradiol (E2) and SHBG levels were detected. Results Seminal plasma and serum TG, TC and LDL levels were positively related to age. Serum TC, TG and LDL were positively related to obesity-associated markers (P < 0.001), while only seminal plasma TG was positively related to them (P < 0.05). For lipids levels in serum and seminal plasma, only TG level had slightly positive correlation between them (r = 0.081, P = 0.042). There was no significant correlation between serum lipids levels and semen parameters. However, seminal plasma TG, TC, LDL and HDL levels were negatively related to one or several semen parameters, including semen volume (SV), sperm concentration (SC), total sperm count (TSC), sperm motility, progressive motility (PR) and total normal-progressively motile sperm counts (TNPMS). Moreover, seminal plasma TG, TC, LDL and HDL levels in patients with oligospermatism, asthenospermia and teratozoospermia were higher than those with normal sperm concentration, motility or morphology. After adjusting age and serum LH, FSH, TT, E2 and SHBG levels, linear regression analysis showed that SV was still significantly correlated with seminal plasma LDL (P = 0.012), both of SC and TSC with seminal plasma HDL (P = 0.028 and 0.002), and both of PR and sperm motility with seminal plasma TC (P = 0.012 and 0.051). Conclusion The abnormal metabolism of lipids in male reproductive system may contribute to male factor infertility. PMID:26726884
Mays, Glen P.; Mamaril, Cezar B.
2015-01-01
Objectives. We investigated changes in hospital participation in local public health systems and the delivery of public health activities over time and assessed the relationship between hospital participation and the scope of activities available in local public health systems. Methods. We used longitudinal observations from the National Longitudinal Survey of Public Health Systems to examine how hospital contributions to the delivery of core public health activities varied in 1998, 2006, and 2012. We then used multivariate regression to assess the relationship between the level of hospital contributions and the overall availability of public health activities in the system. Results. Hospital participation in public health activities increased from 37% in 1998 to 41% in 2006 and down to 39% in 2012. Regression results indicated a positive association between hospital participation in public health activities and the total availability of public health services in the systems. Conclusions. Hospital collaboration does play an important role in the overall availability of public health services in local public health systems. Efforts to increase hospital participation in public health may have a positive impact on the scope of services provided and population health in US communities. PMID:26066929
Analysis on flexible manufacturing system layout using arena simulation software
NASA Astrophysics Data System (ADS)
Fadzly, M. K.; Saad, Mohd Sazli; Shayfull, Z.
2017-09-01
Flexible manufacturing system (FMS) was defined as highly automated group technology machine cell, consisting of a group of processing stations interconnected by an automated material handling and storage system, and controlled by an integrated computer system. FMS can produce parts or products are in the mid-volume, mid-variety production range. The layout system in FMS is an important criterion to design the FMS system to produce a part or product. This facility layout of an FMS involves the positioning of cells within given boundaries, so as to minimize the total projected travel time between cells. Defining the layout includes specifying the spatial coordinates of each cell, its orientation in either a horizontal or vertical position, and the location of its load or unloads point. There are many types of FMS layout such as In-line, loop ladder and robot centered cell layout. The research is concentrating on the design and optimization FMS layout. The final conclusion can be summarized that the objective to design and optimisation of FMS layout for this study is successful because the FMS In-line layout is the best layout based on effective time and cost using ARENA simulation software.
A Study of Pap Smear in HIV-Positive Females.
Madan, Apeksha; Patil, Sunita; Nakate, Leena
2016-12-01
HIV-positive females are more likely to have abnormal Pap smears than HIV-negative women. These abnormal Pap smears are usually associated with low CD4 cell counts and human papilloma virus infection. This was a prospective hospital-based study from April 2013 till March 2014. A total of 250 (both symptomatic and asymptomatic) HIV-positive females were examined in Gynaecology OPD at R.C.S.M. G.M.C and C.P.R. Hospital, Kolhapur, and their cervical smears were taken. They were categorized as per modified Bethesda system 2001. The findings in HIV-positive women were correlated with risk factors (age, disease duration, CD4 count and ART use). To study the spectrum of cytological abnormalities on Pap smear in HIV-positive females and classify precancerous and cancerous lesions in HIV-positive females according to Bethesda system 2001 and to be familiar with terminology and morphological criteria of Bethesda system 2001. To study the association of Pap smears abnormalities among HIV-positive women with their immune status (CD4 count). NILM is the commonest finding (83.2 %) which is subdivided into non-inflammatory, non-specific and specific inflammatory and atrophic smears. Candida vaginitis was the commonest cause of specific inflammatory condition accounted for (2.52 %) of all inflammatory smears. The percentage of squamous cell abnormalities was 12 %: ASCUS + ASC-H-6.22 %, LSIL-2.10 %, HSIL-3.4 % and SCC-0.8 %. The highest incidence of intraepithelial lesions in HIV-positive females was in the age group 31-40 years. There is no association of Pap smear abnormalities among HIV-positive women with their immune status (CD4 count) and duration of ART. Periodic, regular gynaecologic and Pap smear examination would help in early detection of intraepithelial lesions and their treatment so as to prevent invasive malignancy and mortality.
Single-camera visual odometry to track a surgical X-ray C-arm base.
Esfandiari, Hooman; Lichti, Derek; Anglin, Carolyn
2017-12-01
This study provides a framework for a single-camera odometry system for localizing a surgical C-arm base. An application-specific monocular visual odometry system (a downward-looking consumer-grade camera rigidly attached to the C-arm base) is proposed in this research. The cumulative dead-reckoning estimation of the base is extracted based on frame-to-frame homography estimation. Optical-flow results are utilized to feed the odometry. Online positional and orientation parameters are then reported. Positional accuracy of better than 2% (of the total traveled distance) for most of the cases and 4% for all the cases studied and angular accuracy of better than 2% (of absolute cumulative changes in orientation) were achieved with this method. This study provides a robust and accurate tracking framework that not only can be integrated with the current C-arm joint-tracking system (i.e. TC-arm) but also is capable of being employed for similar applications in other fields (e.g. robotics).
Febbraro, Filomena; Rodio, Donatella Maria; Puggioni, Gianluca; Antonelli, Guido; Pietropaolo, Valeria; Trancassini, Maria
2016-12-01
We evaluated the reliability and accuracy of the combined use of MALDI-TOF MS and classical ID VITEK 2 to identify monomicrobial infection in blood culture bottles. In total, 70 consecutive positive blood cultures were included in this study. Positive blood culture bottles were subjected to Gram staining and subcultured on solid media. Isolates grown from such culture media were used for classical ID using VITEK 2 system. In parallel, an aliquot was subjected to a lysing-centrifugation method and used for the identification with the MALDI-TOF system. Results evidenced the correct genus and species identification of 91.4 % of microorganisms responsible for bacteremia with an agreement to the species and the genus level. If compared with the standard method VITEK 2 , our simple and cost-effective sample preparation method would be very useful for rapid identification of microorganisms using blood culture bottles. In fact, the direct method showed rapid and reliable results, especially for the gram-negative group.
Occult hepatitis B infection in children with chronic liver disease.
Srivastava, Anshu; Mathias, Amrita; Yachha, Surender K; Aggarwal, Rakesh
2015-04-01
Occult hepatitis B infection (OBI) may adversely affect the outcome of patients with chronic liver disease (CLD). There are no data on OBI and CLD in children. This study determined the prevalence and effect of OBI in HBsAg-negative CLD children. CLD children were prospectively evaluated with a demographic, clinical, and investigative proforma. All HBsAg-negative CLD cases were tested for exposure to hepatitis B (total anti-HBc, anti-HBs). Serum hepatitis B virus DNA was measured in exposed (total anti-HBc positive) patients. A total of 115 HBsAg-negative CLD children (59 boys, age 9.0±3.6 years) were enrolled. The etiology of CLD was known in 94 cases and 21 children had cryptogenic CLD. Of these, 45 (39.1%) had evidence of HBV exposure (23 total anti-HBc positive, 17 total anti-HBc and anti-HBs positive, five only anti-HBs positive without previous vaccination). The anti-HBc-positive children had a higher Child's score than the anti-HBc-negative children [11 (5-13) vs. 7 (5-13); P=0.00]. A total of 4/45 children had seropositive OBI with serum HBV DNA of 8, 36, 133, and 156 IU/ml, respectively. The proportion of total anti-HBc positivity (8/21 vs. 32/94; P=0.8) and OBI (2/21 vs. 2/94; P=0.1) was similar in cryptogenic CLD and known cause CLD. Seropositive OBI is infrequent in Indian children with CLD. The prevalence is similar in cryptogenic and CLD of known etiology.
Saito, Suzue; Duong, Yen T; Metz, Melissa; Lee, Kiwon; Patel, Hetal; Sleeman, Katrina; Manjengwa, Julius; Ogollah, Francis M; Kasongo, Webster; Mitchell, Rick; Mugurungi, Owen; Chimbwandira, Frank; Moyo, Crispin; Maliwa, Vusumuzi; Mtengo, Helecks; Nkumbula, Tepa; Ndongmo, Clement B; Vere, Nora Skutayi; Chipungu, Geoffrey; Parekh, Bharat S; Justman, Jessica; Voetsch, Andrew C
2017-11-01
Logistical complexities of returning laboratory test results to participants have precluded most population-based HIV surveys conducted in sub-Saharan Africa from doing so. For HIV positive participants, this presents a missed opportunity for engagement into clinical care and improvement in health outcomes. The Population-based HIV Impact Assessment (PHIA) surveys, which measure HIV incidence and the prevalence of viral load (VL) suppression in selected African countries, are returning VL results to health facilities specified by each HIV positive participant within eight weeks of collection. We describe the performance of the specimen and data management systems used to return VL results to PHIA participants in Zimbabwe, Malawi and Zambia. Consenting participants underwent home-based counseling and HIV rapid testing as per national testing guidelines; all confirmed HIV positive participants had VL measured at a central laboratory on either the Roche CAP/CTM or Abbott m2000 platform. On a bi-weekly basis, a dedicated data management team produced logs linking the VL test result with the participants' contact information and preferred health facility; project staff sent test results confidentially via project drivers, national courier systems, or electronically through an adapted short message service (SMS). Participants who provided cell phone numbers received SMS or phone call alerts regarding availability of VL results. From 29,634 households across the three countries, 78,090 total participants 0 to 64 years in Zimbabwe and Malawi and 0 to 59 years in Zambia underwent blood draw and HIV testing. Of the 8391 total HIV positive participants identified, 8313 (99%) had VL tests performed and 8245 (99%) of these were returned to the selected health facilities. Of the 5979 VL results returned in Zimbabwe and Zambia, 85% were returned within the eight-week goal with a median turnaround time of 48 days (IQR: 33 to 61). In Malawi, where exact return dates were unavailable all 2266 returnable results reached the health facilities by 11 weeks. The first three PHIA surveys returned the vast majority of VL results to each HIV positive participant's preferred health facility within the eight-week target. Even in the absence of national VL monitoring systems, a system to return VL results from a population-based survey is feasible, but it requires developing laboratory and data management systems and dedicated staff. These are likely important requirements to strengthen return of results systems in routine clinical care. © 2017 The Authors. Journal of the International AIDS Society published by John Wiley & sons Ltd on behalf of the International AIDS Society.
Particulate matter in animal rooms housing mice in microisolation caging.
Langham, Gregory L; Hoyt, Robert F; Johnson, Thomas E
2006-11-01
Reactions to allergens created by laboratory animals are among the most frequently encountered occupational illnesses associated with research animals. Personnel are exposed to these allergens through airborne particulate matter. Although the use of microisolation caging systems can reduce particulate matter concentrations in rooms housing mice, the operating parameters of ventilated caging systems vary extensively. We compared room air in mouse rooms containing 5 different types of caging: 1) individually ventilated caging under positive pressure with filtered intake air and exhaust air returned to the room (VCR+), 2) individually ventilated caging under negative pressure with exhaust air returned to the room (VCR-), 3) individually ventilated caging under positive pressure with exhaust air returned to the heating, ventilation, and air-conditioning (HVAC) system, 4) individually ventilated caging under negative pressure with exhaust air returned to the HVAC system, and 5) static microisolation cages. We found that rooms under VCR conditions had fewer large particles than did those under other conditions, but the numbers of 0.3 microm particles did not differ significantly among systems. Static, positive or negative pressure applied to caging units as well as route of air exhaust were found to have little influence on the total number of particles in the atmosphere. Therefore, considering the heat load, odor, and overall particulate concentration in the room, placing individually ventilated caging under negative pressure with exhaust air returned to the HVAC system appears to be the optimal overall choice when using microisolation housing for rodents.
Remote vs. head-mounted eye-tracking: a comparison using radiologists reading mammograms
NASA Astrophysics Data System (ADS)
Mello-Thoms, Claudia; Gur, David
2007-03-01
Eye position monitoring has been used for decades in Radiology in order to determine how radiologists interpret medical images. Using these devices several discoveries about the perception/decision making process have been made, such as the importance of comparisons of perceived abnormalities with selected areas of the background, the likelihood that a true lesion will attract visual attention early in the reading process, and the finding that most misses attract prolonged visual dwell, often comparable to dwell in the location of reported lesions. However, eye position tracking is a cumbersome process, which often requires the observer to wear a helmet gear which contains the eye tracker per se and a magnetic head tracker, which allows for the computation of head position. Observers tend to complain of fatigue after wearing the gear for a prolonged time. Recently, with the advances made to remote eye-tracking, the use of head-mounted systems seemed destined to become a thing of the past. In this study we evaluated a remote eye tracking system, and compared it to a head-mounted system, as radiologists read a case set of one-view mammograms on a high-resolution display. We compared visual search parameters between the two systems, such as time to hit the location of the lesion for the first time, amount of dwell time in the location of the lesion, total time analyzing the image, etc. We also evaluated the observers' impressions of both systems, and what their perceptions were of the restrictions of each system.
Brown, Lawrence H; Chaiechi, Taha; Buettner, Petra G; Canyon, Deon V; Crawford, J Mac; Judd, Jenni
2013-02-01
To evaluate the impact of changing energy prices on Australian ambulance systems. Generalised estimating equations were used to analyse contemporaneous and lagged relationships between changes in energy prices and ambulance system performance measures in all Australian State/Territory ambulance systems for the years 2000-2010. Measures included: expenditures per response; labour-to-total expenditure ratio; full-time equivalent employees (FTE) per 10,000 responses; average salary; median and 90th percentile response time; and injury compensation claims. Energy price data included State average diesel price, State average electricity price, and world crude oil price. Changes in diesel prices were inversely associated with changes in salaries, and positively associated with changes in ambulance response times; changes in oil prices were also inversely associated with changes in salaries, as well with staffing levels and expenditures per ambulance response. Changes in electricity prices were positively associated with changes in expenditures per response and changes in salaries; they were also positively associated with changes in injury compensation claims per 100 FTE. Changes in energy prices are associated with changes in Australian ambulance systems' resource, performance and safety characteristics in ways that could affect both patients and personnel. Further research is needed to explore the mechanisms of, and strategies for mitigating, these impacts. The impacts of energy prices on other aspects of the health system should also be investigated. © 2013 The Authors. ANZJPH © 2013 Public Health Association of Australia.
Zhe Cao; Shaojie Su; Hao Tang; Yixin Zhou; Zhihua Wang; Hong Chen
2017-07-01
With the aging of population, the number of Total Hip Replacement Surgeries (THR) increased year by year. In THR, inaccurate position of the implanted prosthesis may lead to the failure of the operation. In order to reduce the failure rate and acquire the real-time pose of Anterior Pelvic Plane (APP), we propose a measurement system in this paper. The measurement system includes two parts: Initial Pose Measurement Instrument (IPMI) and Real-time Pose Measurement Instrument (RPMI). IPMI is used to acquire the initial pose of the APP, and RPMI is used to estimate the real-time pose of the APP. Both are composed of an Inertial Measurement Unit (IMU) and magnetometer sensors. To estimate the attitude of the measurement system, the Extended Kalman Filter (EKF) is adopted in this paper. The real-time pose of the APP could be acquired together with the algorithm designed in the paper. The experiment results show that the Root Mean Square Error (RMSE) is within 1.6 degrees, which meets the requirement of THR operations.
Study on the influence on water ecosystem by a lake inflow filtration system
NASA Astrophysics Data System (ADS)
Wu, Sushu; Gao, Shipei; Hu, Xiaodong; Weng, Songgan; Guo, Liuchao
2018-06-01
Lakes play important roles in the economic-social sustainable development. However, due to unreasonable development and urbanization in recent years, lake water pollution and ecological degradation have occurred in China. The improvement of the lake inflow water quality is very important. A filtration system includes Gravel filtering system, Aquatic plant area and Ecological bag area was established. The test river is one of the typical lake inflow river and located in the river network in the Chang Dang lake, China. Water quality, zooplankton and phytoplankton in the inflow river were observed form July to mid-August in order to analyze the general process. The average removal rate of NH3-N (ammonia nitrogen) TN (total nitrogen) and TP (total phosphorus) is 28.33, 25.76 and 24.43 %, respectively. The Pantle-Buck method was used to evaluate the water quality and the B/T index was used to evaluate the nutrition situation. The B/T values were reduced by 20 % and the SI pollution index was reduced by 11.8 %. Therefore, a positive effect on the water's ecological restoration was achieved by the filtration system.
Klauer, Christian; Schauer, Thomas; Reichenfelser, Werner; Karner, Jakob; Zwicker, Sven; Gandolla, Marta; Ambrosini, Emilia; Ferrante, Simona; Hack, Marco; Jedlitschka, Andreas; Duschau-Wicke, Alexander; Gföhler, Margit; Pedrocchi, Alessandra
2014-01-01
Within the European project MUNDUS, an assistive framework was developed for the support of arm and hand functions during daily life activities in severely impaired people. This contribution aims at designing a feedback control system for Neuro-Muscular Electrical Stimulation (NMES) to enable reaching functions in people with no residual voluntary control of the arm and shoulder due to high level spinal cord injury. NMES is applied to the deltoids and the biceps muscles and integrated with a three degrees of freedom (DoFs) passive exoskeleton, which partially compensates gravitational forces and allows to lock each DOF. The user is able to choose the target hand position and to trigger actions using an eyetracker system. The target position is selected by using the eyetracker and determined by a marker-based tracking system using Microsoft Kinect. A central controller, i.e., a finite state machine, issues a sequence of basic movement commands to the real-time arm controller. The NMES control algorithm sequentially controls each joint angle while locking the other DoFs. Daily activities, such as drinking, brushing hair, pushing an alarm button, etc., can be supported by the system. The robust and easily tunable control approach was evaluated with five healthy subjects during a drinking task. Subjects were asked to remain passive and to allow NMES to induce the movements. In all of them, the controller was able to perform the task, and a mean hand positioning error of less than five centimeters was achieved. The average total time duration for moving the hand from a rest position to a drinking cup, for moving the cup to the mouth and back, and for finally returning the arm to the rest position was 71 s. PMID:25228853
Klauer, Christian; Schauer, Thomas; Reichenfelser, Werner; Karner, Jakob; Zwicker, Sven; Gandolla, Marta; Ambrosini, Emilia; Ferrante, Simona; Hack, Marco; Jedlitschka, Andreas; Duschau-Wicke, Alexander; Gföhler, Margit; Pedrocchi, Alessandra
2014-01-01
Within the European project MUNDUS, an assistive framework was developed for the support of arm and hand functions during daily life activities in severely impaired people. This contribution aims at designing a feedback control system for Neuro-Muscular Electrical Stimulation (NMES) to enable reaching functions in people with no residual voluntary control of the arm and shoulder due to high level spinal cord injury. NMES is applied to the deltoids and the biceps muscles and integrated with a three degrees of freedom (DoFs) passive exoskeleton, which partially compensates gravitational forces and allows to lock each DOF. The user is able to choose the target hand position and to trigger actions using an eyetracker system. The target position is selected by using the eyetracker and determined by a marker-based tracking system using Microsoft Kinect. A central controller, i.e., a finite state machine, issues a sequence of basic movement commands to the real-time arm controller. The NMES control algorithm sequentially controls each joint angle while locking the other DoFs. Daily activities, such as drinking, brushing hair, pushing an alarm button, etc., can be supported by the system. The robust and easily tunable control approach was evaluated with five healthy subjects during a drinking task. Subjects were asked to remain passive and to allow NMES to induce the movements. In all of them, the controller was able to perform the task, and a mean hand positioning error of less than five centimeters was achieved. The average total time duration for moving the hand from a rest position to a drinking cup, for moving the cup to the mouth and back, and for finally returning the arm to the rest position was 71 s.
The accuracy of a hand-held navigation system in total knee arthroplasty.
Loh, Bryan; Chen, Jerry Yongqiang; Yew, Andy Khye Soon; Pang, Hee Nee; Tay, Darren Keng Jin; Chia, Shi-Lu; Lo, Ngai Nung; Yeo, Seng Jin
2017-03-01
This study aims to evaluate the effectiveness of a new hand-held navigation system. The authors of this study hypothesize that this navigation system will improve overall lower limb alignment and implant placement without causing a delay in surgery. Two hundred consecutive patients diagnosed with tricompartmental osteoarthritis and underwent total knee arthroplasty by a senior surgeon were included in this study. One hundred patients underwent TKA using the hand-held navigation system, while the other 100 patients underwent TKA using the conventional technique. The primary outcomes of this study were the overall alignment of the lower limb and the position of the components. This was determined radiologically using the: (1) Hip-Knee-Ankle angle (HKA) for lower limb alignment; (2) Coronal Femoral-Component angle (CFA); and (3) Coronal Tibia-Component angle (CTA) for component position. Normal alignment was taken as 180° ± 3° for the HKA and 90° ± 3° for both the CFA and CTA. For the CFA, the proportion of outliers was 7 and 17% in the hand-held navigation and conventional group, respectively (p = 0.030). For the HKA and CTA, there was no difference in the proportion of outliers between the two groups. The duration of surgery was 73 ± 9 min and 87 ± 15 min in the hand-held navigation and conventional group, respectively (p < 0.001). This hand-held navigation system is an effective intraoperative tool for reducing the proportion of outliers for femoral implant placement as well as the duration of surgery. The authors conclude that it can be considered for use to check femoral implant placement intra-operatively. III.
Lobbezoo, D J A; van Kampen, R J W; Voogd, A C; Dercksen, M W; van den Berkmortel, F; Smilde, T J; van de Wouw, A J; Peters, F P J; van Riel, J M G H; Peters, N A J B; de Boer, M; Peer, P G M; Tjan-Heijnen, V C G
2016-02-01
The objective of this study was to present initial systemic treatment choices and the outcome of hormone receptor-positive (HR+) metastatic breast cancer. All the 815 consecutive patients diagnosed with metastatic breast cancer in 2007-2009 in eight participating hospitals were identified. From the 611 patients with HR+ disease, a total of 520 patients with HER2-negative (HER2-) breast cancer were included. Initial palliative systemic treatment was registered. Progression-free survival (PFS) and overall survival (OS) per initial palliative systemic therapy were obtained using the Kaplan-Meier method and compared using the log-rank test. From the total of 520 patients with HR+/HER2- metastatic breast cancer, 482 patients (93%) received any palliative systemic therapy. Patients that received initial chemotherapy (n = 116) were significantly younger, had less comorbidity, had received more prior adjuvant systemic therapy and were less likely to have bone metastasis only compared with patients that received initial endocrine therapy (n = 366). Median PFS of initial palliative chemotherapy was 5.3 months [95% confidence interval (CI) 4.2-6.2] and of initial endocrine therapy 13.3 months (95% CI 11.3-15.5), with a median OS of 16.1 and 36.9 months, respectively. Initial chemotherapy was also associated with worse outcome in terms of PFS and OS after adjustment for prognostic factors. A high percentage of patients with HR+ disease received initial palliative chemotherapy, which was associated with worse outcome, even after adjustment of relevant prognostic factors. © The Author 2015. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Solano-Altamirano, J M; Goldman, Saul
2015-12-01
We determined the total system elastic Helmholtz free energy, under the constraints of constant temperature and volume, for systems comprised of one or more perfectly bonded hard spherical inclusions (i.e. "hard spheres") embedded in a finite spherical elastic solid. Dirichlet boundary conditions were applied both at the surface(s) of the hard spheres, and at the outer surface of the elastic solid. The boundary conditions at the surface of the spheres were used to describe the rigid displacements of the spheres, relative to their initial location(s) in the unstressed initial state. These displacements, together with the initial positions, provided the final shape of the strained elastic solid. The boundary conditions at the outer surface of the elastic medium were used to ensure constancy of the system volume. We determined the strain and stress tensors numerically, using a method that combines the Neuber-Papkovich spherical harmonic decomposition, the Schwartz alternating method, and Least-squares for determining the spherical harmonic expansion coefficients. The total system elastic Helmholtz free energy was determined by numerically integrating the elastic Helmholtz free energy density over the volume of the elastic solid, either by a quadrature, or a Monte Carlo method, or both. Depending on the initial position of the hard sphere(s) (or equivalently, the shape of the un-deformed stress-free elastic solid), and the displacements, either stationary or non-stationary Helmholtz free energy minima were found. The non-stationary minima, which involved the hard spheres nearly in contact with one another, corresponded to lower Helmholtz free energies, than did the stationary minima, for which the hard spheres were further away from one another.
Gong, Wei-Wei; Zhang, Yi-Sheng; He, Ling-Yan; Luan, Sheng-Ji
2011-02-01
In order to obtain ammonia volatilization flux and volatilization loss rate in the vegetable field and investigate their relationship with environmental factors, an on-line monitoring system was used to measure the ammonia volatilization in the vegetable (Brassica rapa L. and lettuce) field after urea application during January to September, 2009. The system included a wind tunnel system, a gas collector and an online analyzer system with ion chromatography. The time resolution of measurement was 15 min. The recovery of the system was (92.6 +/- 3.4)%; the accumulated ammonia volatilization within 15 d continuous sampling after fertilization was regarded as the total loss. The accumulated ammonia volatilization of 12 d continuous sampling after fertilization accounted for (85.4 +/- 5.2)% of the total volatilization. The ammonia volatilization loss of broadcasting basal dressing and top dressing for Brassica rapa L. were 23.6% and 21.3%, respectively. The ammonia volatilization loss of holing basal dressing and top dressing for lettuce were 17.6% and 24.0%, respectively. The ammonia volatilization in the vegetable field mostly occurred in the first 2-3 weeks after fertilization. The ammonia volatilization flux had significant positive correlation with the nitrogen application rate, while the ammonia volatilization loss rate had negative correlation with the nitrogen application rate. The ammonia volatilization flux was positively correlated with the soil temperature (r = 0.041, p < 0.05) and the air temperature (r = 0.049, p < 0.01), while not significantly associated with the air humidity and the soil moisture. Temperature was found to be a main factor influencing the ammonia volatilization in the vegetable field.
Yilmaz, Soner; Unlu, Aytekin; Cetinkaya, Riza Aytac; Yapar, Mehmet; Avci, Ismail Yasar; Yilmaz, Sebahattin; Eyigun, Can Polat
2016-04-01
Screening of blood donations for antibodies against hepatitis B core antigen (anti-HBc) is used to prevent transfusion transmitted hepatitis B virus (HBV) infection. In this study, we studied the magnitude of blood donor gain by using a re-entry mechanism in our Blood Bank of Gulhane Military Academy of Medicine. Between January and May 2013, 5148 voluntary blood donors were screened by ELISA method for HBsAg, anti-HBc total and other screening markers, prospectively. Samples with repeated reactivity for the presence of anti-HBc were further tested with four supplemental assays. We detected 515 (10%) anti-HBc positive and 4612 (90%) anti-HBc negative cases in 5127 HBsAg negative serum samples. A total of 461 (89.5%) blood units were reactive for at least one additional serologic parameter and 54 were (10.5%) negative. Isolated anti-HBc positivity rate was 1.3% (69/5127). In the isolated anti-HBc positive samples, 54 were also anti-HBe and HBeAg negative. HBV DNA was not detected in any of the samples. Applying the EDQM criteria would decrease our blood donor loss from 10% to 5.4%. As alternative re-entry mechanisms have already been presented in the literature, institution of a new policy is needed to enhance the limited blood donor pool in our system. Copyright © 2016. Published by Elsevier Ltd.
Pan, Yueh-Chiu; Huang, Pei-Wen; Lee, Jin-Chuan; Chang, Ching-Lu
2012-04-01
There have been major changes to the medical care system and heightened standards for quality in the nursing profession in recent decades. Multifunctional capabilities are closely related to individual working attitudes, and work satisfaction directly affects group performance. Hospital administrators increasingly expect to utilize nursing staffs flexibly in terms of working hours and shift rotation assignments. This study addresses the need to provide appropriate educational training to nurses and effectively delegate and utilize human resources in order to help nurses adapt to the rapidly changing medical environment. This study on nursing staff in Tainan area explored the relationships between job rotation, work performance and satisfaction. We used a questionnaire sampling method to survey nurses working in the Tainan area of southern Taiwan. Subjects were volunteers and a total 228 valid questionnaires (99.13%) were returned out of a total 230 sent. Both job satisfaction and performance correlated positively with job rotation perception and intention; Job satisfaction and job performance were positively related; Job satisfaction was found to affect work performance via job rotation perception and intention. This study found the hospital nursing staff rotation plan to be an effective management method that facilitates social evolution to increase positive perceptions of work rotation. Nursing staffs thus become more accepting of new positions that may enhance job satisfaction.
Varley, Matthew C; Di Salvo, Valter; Modonutti, Mattia; Gregson, Warren; Mendez-Villanueva, Alberto
2018-03-01
This study investigated the effects of successive matches on match-running in elite under-23 soccer players during an international tournament. Match-running data was collected using a semi-automated multi-camera tracking system during an international under-23 tournament from all participating outfield players. Players who played 100% of all group stage matches were included (3 matches separated by 72 h, n = 44). Differences in match-running performance between matches were identified using a generalised linear mixed model. There were no clear effects for total, walking, jogging, running, high-speed running and sprinting distance between matches 1 and 3 (effect size (ES); -0.32 to 0.05). Positional analysis found that sprint distance was largely maintained from matches 1 to 3 across all positions. Attackers had a moderate decrease in total, jogging and running distance between matches 1 and 3 (ES; -0.72 to -0.66). Classifying players as increasers or decreasers in match-running revealed that match-running changes are susceptible to individual differences. Sprint performance appears to be maintained over successive matches regardless of playing position. However, reductions in other match-running categories vary between positions. Changes in match-running over successive matches affect individuals differently; thus, players should be monitored on an individual basis.
Imaging System for Vaginal Surgery.
Taylor, G Bernard; Myers, Erinn M
2015-12-01
The vaginal surgeon is challenged with performing complex procedures within a surgical field of limited light and exposure. The video telescopic operating microscope is an illumination and imaging system that provides visualization during open surgical procedures with a limited field of view. The imaging system is positioned within the surgical field and then secured to the operating room table with a maneuverable holding arm. A high-definition camera and Xenon light source allow transmission of the magnified image to a high-definition monitor in the operating room. The monitor screen is positioned above the patient for the surgeon and assistants to view real time throughout the operation. The video telescopic operating microscope system was used to provide surgical illumination and magnification during total vaginal hysterectomy and salpingectomy, midurethral sling, and release of vaginal scar procedures. All procedures were completed without complications. The video telescopic operating microscope provided illumination of the vaginal operative field and display of the magnified image onto high-definition monitors in the operating room for the surgeon and staff to simultaneously view the procedures. The video telescopic operating microscope provides high-definition display, magnification, and illumination during vaginal surgery.
1998-02-12
HAARP ). 14. SUBJECT TERMS Global Positioning System (GPS), High Frequency Active Auroral Research Program ( HAARP ), ionosphere, radiowave...Scintillation Simulation 23 4.10 Automated Calibrations 23 5. HAARP Activities 24 5.1 Development of HAARP Diagnostics 24 5.2 Facilitation of... HAARP Operations and Broader Scientific Collaborations 27 5.3 Public Relations 28 6. Publications 30 References 30 Acronyms and Initials 30 Appendix
Patriot Advanced Capability-3 Missile Segment Enhancement (PAC-3 MSE)
2015-12-01
Threshold Demonstrated Performance Current Estimate System Training Proficiency Level Soldiers (Operators, Maintainers, and Leaders) are able to...constructive training environments by using TADSS to conduct multi- level training for both operators and maintenance personnel. With the addition...0.0 Total 6037.0 6037.0 N/A 6276.9 6722.3 6722.3 6900.3 Current APB Cost Estimate Reference Army Cost Position dated February 28, 2014 Confidence Level
Measuring Concentrations of Particulate 140La in the Air
Okada, Colin E.; Kernan, Warnick J.; Keillor, Martin E.; ...
2016-05-01
Air sampling systems were deployed to measure the concentration of radioactive material in the air during the Full-Scale Radiological Dispersal Device experiments. The air samplers were positioned 100-600 meters downwind of the release point. The filters were collected immediately and analyzed in the field. Quantities for total activity collected on the air filters are reported along with additional information to compute the average or integrated air concentrations.
NASA Astrophysics Data System (ADS)
Ulukavak, Mustafa; Yalcinkaya, Mualla
2016-04-01
The Global Positioning System (GPS) is used as an important tool for ionosphere monitoring and obtaining the Total Electron Content (TEC). GPS satellites, positioned in the Earth's orbit, are used as sensors to investigate the space weather conditions. In this study, solar and geomagnetic activity variations were investigated between the dates 1 March-30 June 2015 for the mid-latitude region. GPS-TEC variations were calculated for each selected International GNSS Service (IGS) station in Europe. GNSS data was obtained from Crustal Dynamics Data and Information System (CDDIS) archive. Solar and geomagnetic activity indices (Kp, F10.7 ve Dst) were obtained from the Oceanic and Atmospheric Administration (NOAA), the Canadian Space Weather Forecast Centre (CSWFC) and Data Analysis Center for geomagnetism and Space Magnetism Graduate School of Science, Kyoto University (WDC) archives. GPS-TEC variations were determined for the quiet periods of the solar and geomagnetic activities. GPS-TEC changes were then compared with respect to the quiet periods of the solar and geomagnetic activities. Global Ionosphere Maps (GIM) IONEX files, obtained from the IGS analysis center, was used to check the robustness of the GPS-TEC variations. The investigations revealed that it is possible to use the GPS-TEC data for monitoring the ionospheric disturbances.
The 4D-var Estimation of North Korean Rocket Exhaust Emissions Into the Ionosphere
NASA Astrophysics Data System (ADS)
Ssessanga, Nicholas; Kim, Yong Ha; Choi, Byungyu; Chung, Jong-Kyun
2018-03-01
We have developed a four-dimensional variation data assimilation technique (4D-var) and utilized it to reconstruct three-dimensional images of the ionospheric hole created during Kwangmyongsong-4 rocket launch. Kwangmyongsong-4 was launched southward from North Korea Sohae space center (124.7°E, 39.6°N) at 00:30 UT on 7 February 2016. The data assimilated were Global Positioning System total electron content from the South Korean Global Positioning System-receiver network. Due to lack of publicized information about Kwangmyongsong-4, the rocket was assumed to inherit its technology from previous launches (Taepodong-2). The created ionospheric hole was assumed to be made by neutral molecules, water (H2O) and hydrogen (H2), deposited in exhaust plumes. The dispersion model was developed based on advection and diffusion equation, and a simple asymmetric diffusion model assumed. From the analysis, using the adjoint technique, we estimated an ionospheric hole with the largest depletion existing around 6-7 min after launch and gradually recovering within 30 min. These results are in agreement with temporal total electron content analyses of the same event from previous studies. Furthermore, Kwangmyongsong-4 second stage exhaust emissions were estimated as 1.9 × 1026 s-1 of which 40% was H2 and the rest H2O.
Discovering frequently recurring movement sequences in team-sport athlete spatiotemporal data.
Sweeting, Alice J; Aughey, Robert J; Cormack, Stuart J; Morgan, Stuart
2017-12-01
Athlete external load is typically analysed from predetermined movement thresholds. The combination of movement sequences and differences in these movements between playing positions is also currently unknown. This study developed a method to discover the frequently recurring movement sequences across playing position during matches. The external load of 12 international female netball athletes was collected by a local positioning system during four national-level matches. Velocity, acceleration and angular velocity were calculated from positional (X, Y) data, clustered via one-dimensional k-means and assigned a unique alphabetic label. Combinations of velocity, acceleration and angular velocity movement were compared using the Levenshtein distance and similarities computed by the longest common substring problem. The contribution of each movement sequence, according to playing position and relative to the wider data set, was then calculated via the Minkowski distance. A total of 10 frequently recurring combinations of movement were discovered, regardless of playing position. Only the wing attack, goal attack and goal defence playing positions are closely related. We developed a technique to discover the movement sequences, according to playing position, performed by elite netballers. This methodology can be extended to discover the frequently recurring movements within other team sports and across levels of competition.
Cai, Shuangqi; Chen, Yiqiang; Song, Dezhi; Kong, Jinliang; Wu, Yanbin; Lu, Huasong
2016-11-01
The aim of the present study was to evaluate the imipenem-resistant mechanism via the outer membrane protein (OMP) OprD2 and metal β-lactamase expression in the cell wall of Pseudomonas aeruginosa . The Pseudomonas aeruginosa was clinically separated and validated by VITEK-2 full-automatic bacteria analyzer. Drug resistance, sensitive antibiotics and minimum inhibitory concentration (MIC) were tested using the drug sensitivity analysis system. The phenotype positive strains of MBL genes were screened using the Kirby-Bauer diffusion method by adding metal ion-chelating agent EDTA on the imipenem susceptibility paper. IMP-1, VIM-1 and SPM metaloenzyme genes were tested by polymerase chain reaction (PCR)-telomeric repeat amplification protocol (TRAP). The OMP OprD2 genes were tested by PCR-TRAP, and the protein expression was tested using western blot analysis. The location of OMP OprD2 was confirmed using the sodium salicylate inhibition test. The results showed that 80 portions (40%) of MBL-positive strains were screened out of 200 specimens. Imipenem-resistant Pseudomonas aeruginosa (IRPA) and MIC values were significantly higher than quality control bacteria and control bacteria (P<0.05). A total of 35 cases with IMP-1 positive, 20 with VIM-1 positive, 16 with SPM positive, 5 with 2 positive genes and 4 with 3 positive genes were screened among MBL positive strains. A total of 150 portions (75%) of OprD2 deficiencies were screened from 200 specimens. The standard strains and sensitive strains showed OprD2 protein bands at 45 kDa while no OprD2 protein bands appeared in OprD2 deficiency strains. It was in accordance with gene detection. In conclusion, OMP OprD2 deficiency and MBL phenotype positivity may be important mechanisms of IRPA.
Shariati, Laleh; Validi, Majid; Hasheminia, Ali Mohammad; Ghasemikhah, Reza; Kianpour, Fariborz; Karimi, Ali; Nafisi, Mohammad Reza; Tabatabaiefar, Mohammad Amin
2016-01-01
Background: A diversity of virulence factors work together to create the pathogenicity of Staphylococcus aureus. These factors include cell surface components that promote adherence to surfaces as well as exoproteins such as Panton-Valentine leukocidin (PVL), encoded by the luk-PV genes, that invade or bypass the immune system and are toxic to the host, thereby enhancing the severity of infections caused by methicillin-resistant Staphylococcus aureus (MRSA). Objectives: The aim of this study was to determine the frequency of PVL-positive MRSA strains by real-time PCR and their antibiotic susceptibility patterns by phenotypic test. Materials and Methods: In total, 284 Staphylococcus isolates, identified by phenotypic methods from clinical samples of Shahrekord University Hospitals, Shahrekord, Iran, were tested for nuc, mecA, and PVL genes by TaqMan real-time PCR. The antibiotic susceptibility patterns of PVL-containing MRSA strains were determined via the disk diffusion method. Results: In total, 196 isolates (69%) were nuc positive (i.e., S. aureus); of those isolates, 96 (49%) were mecA positive (MRSA). Eighteen (18.8%) of the 96 MRSA positive and 3 (3%) of the 100 methicillin-susceptible Staphylococcus aureus (MSSA) strains were PVL positive. PVL-positive MRSA strains were mostly recovered from tracheal specimens. Eight PVL-positive MRSA strains were resistant to all the tested antibiotics except vancomycin. A significant correlation (P = 0.001) was found between the mecA positivity and the presence of luk-PV genes. Conclusions: Community acquired (CA)-MRSA is becoming a public health concern in many parts of the world, including Asian countries. The variable prevalence of luk-PV-positive MRSA isolates in different regions and their rather high frequency in pneumonia necessitate the application of rapid diagnostic methods such as real-time PCR to improve treatment effectiveness. PMID:27099685
Balaguera, Henri U; Wise, Diana; Ng, Chun Yin; Tso, Han-Wen; Chiang, Wan-Lin; Hutchinson, Aimee M; Galvin, Tracy; Hilborne, Lee; Hoffman, Cathy; Huang, Chi-Cheng; Wang, C Jason
2017-05-04
Hospitalized patients in the United States experience falls at a rate of 2.6 to 17.1 per 1000 patient-days, with the majority occurring when a patient is moving to, from, and around the bed. Each fall with injury costs an average of US $14,000. The aim was to conduct a technology evaluation, including feasibility, usability, and user experience, of a medical sensor-based Intranet of things (IoT) system in facilitating nursing response to bed exits in an acute care hospital. Patients 18 years and older with a Morse fall score of 45 or greater were recruited from a 35-bed medical-surgical ward in a 317-bed Massachusetts teaching hospital. Eligible patients were recruited between August 4, 2015 and July 31, 2016. Participants received a sensor pad placed between the top of their mattress and bed sheet. The sensor pad was positioned to monitor movement from patients' shoulders to their thighs. The SensableCare System was evaluated for monitoring patient movement and delivering timely alerts to nursing staff via mobile devices when there appeared to be a bed-exit attempt. Sensor pad data were collected automatically from the system. The primary outcomes included number of falls, time to turn off bed-exit alerts, and the number of attempted bed-exit events. Data on patient falls were collected by clinical research assistants and confirmed with the unit nurse manager. Explanatory variables included room locations (zones 1-3), day of the week, nursing shift, and Morse Fall Scale (ie, positive fall history, positive secondary diagnosis, positive ambulatory aid, weak impaired gait/transfer, positive IV/saline lock, mentally forgets limitations). We also assessed user experience via nurse focus groups. Qualitative data regarding staff interactions with the system were collected during two focus groups with 25 total nurses, each lasting approximately 1.5 hours. A total of 91 patients used the system for 234.0 patient-days and experienced no bed falls during the study period. On average, patients were assisted/returned to bed 46 seconds after the alert system was triggered. Response times were longer during the overnight nursing shift versus day shift (P=.005), but were independent of the patient's location on the unit. Focus groups revealed that nurses found the system integrated well into the clinical nursing workflow and the alerts were helpful in patient monitoring. A medical IoT system can be integrated into the existing nursing workflow and may reduce patient bed fall risk in acute care hospitals, a high priority but an elusive patient safety challenge. By using an alerting system that sends notifications directly to nurses' mobile devices, nurses can equally respond to unassisted bed-exit attempts wherever patients are located on the ward. Further study, including a fully powered randomized controlled trial, is needed to assess effectiveness across hospital settings. ©Henri U Balaguera, Diana Wise, Chun Yin Ng, Han-Wen Tso, Wan-Lin Chiang, Aimee M Hutchinson, Tracy Galvin, Lee Hilborne, Cathy Hoffman, Chi-Cheng Huang, C Jason Wang. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 04.05.2017.
NASA Astrophysics Data System (ADS)
Saloum, S.; Naddaf, M.; Alkhaled, B.
2008-02-01
N2-x% Ar plasma gas mixture, generated in a hollow cathode RF discharge system, has been characterized by both optical emission spectroscopy (OES) and double Langmuir probe, as a function of experimental parameters: total pressure (5-33 Pa), and different fractions of argon (7 <= x <= 80), at a constant applied RF power of 300 W. N2 dissociation degree has been investigated qualitatively by both the actinometry method and the ratio I_N/I_{N_2} of the atomic nitrogen line emission intensity at 672.3 nm to the vibrational band (0-0) of the N2 second positive system at 337.1 nm. Both methods showed that the increase in argon fraction enhances the dissociation of N2, with a maximum at x = 50 for the pressure of 5 Pa, although the two methods give two opposite trends as a function of total pressure. Spectroscopic measurements showed that the vibrational temperature of the N2 second positive system increases with both argon fraction and total pressure increase, it lies between 4900 and 12 300 K. Langmuir probe measurements showed that, in the remote zone, the electron temperature falls in the range 1.57-1.75 eV, the N_{2}^{+} density varies between 5 × 109 and 1.4 × 1010 cm-3 and that both the plasma ionization degree and electron temperature increase towards the source. In addition, the process of plasma-polyamide (PA) surface interaction, in the remote plasma zone, has been studied through OES analysis during plasma treatment of PA to monitor the possible emissions due to the polymer etching. An increase in atomic nitrogen line (672.3 nm) intensity is obtained, atomic carbon line (833.52 nm) and the band emission (0-0) from the CN (B 2Σ+-X 2Σ+) violet system were observed. The PA surface modification has been confirmed through the improvement of its hydrophilic character as the water contact angle measured after the plasma treatment significantly decreased.
NASA Astrophysics Data System (ADS)
Manojlović, Stojadin M.; Barbarić, Žarko P.; Mitrović, Srđan T.
2015-06-01
A new tracking design for laser systems with different arrangements of a quadrant photodetector, based on the principle of active disturbance rejection control is suggested. The detailed models of quadrant photodetector with standard add-subtract, difference-over-sum and diagonal-difference-over-sum algorithms for displacement signals are included in the control loop. Target moving, non-linearity of a photodetector, parameter perturbations and exterior disturbances are treated as a total disturbance. Active disturbance rejection controllers with linear extended state observers for total disturbance estimation and rejection are designed. Proposed methods are analysed in frequency domain to quantify their stability characteristics and disturbance rejection performances. It is shown through simulations, that tracking errors are effectively compensated, providing the laser spot positioning in the area near the centre of quadrant photodetector where the mentioned algorithms have the highest sensitivity, which provides tracking of the manoeuvring targets with high accuracy.
Engineering model 8-cm thruster subsystem
NASA Technical Reports Server (NTRS)
Herron, B. G.; Hyman, J.; Hopper, D. J.; Williamson, W. S.; Dulgeroff, C. R.; Collett, C. R.
1978-01-01
An Engineering Model (EM) 8 cm Ion Thruster Propulsion Subsystem was developed for operation at a thrust level 5 mN (1.1 mlb) at a specific impulse 1 sub sp = 2667 sec with a total system input power P sub in = 165 W. The system dry mass is 15 kg with a mercury-propellant-reservoir capacity of 8.75 kg permitting uninterrupted operation for about 12,500 hr. The subsystem can be started from a dormant condition in a time less than or equal to 15 min. The thruster has a design lifetime of 20,000 hr with 10,000 startup cycles. A gimbal unit is included to provide a thrust vector deflection capability of + or - 10 degrees in any direction from the zero position. The EM subsystem development program included thruster optimization, power-supply circuit optimization and flight packaging, subsystem integration, and subsystem acceptance testing including a cyclic test of the total propulsion package.
Hammad, M; Eissa, M; Fathi, S
2016-08-01
Systemic lupus erythematosus (SLE) is a prototypic multisystem autoimmune disorder. The total damage in a patient with SLE may result from SLE itself or from any other pathologic process. The aim of this study was to assess risk factors of greater damage in a sample of Egyptian SLE patients. This Egyptian multicenter retrospective study included 100 SLE patients: 64 patients from Cairo University Hospitals and 36 patients from Zagazig University Hospitals. The Systemic Lupus International Collaborative Clinics (SLICC)/American College of Rheumatology (ACR) Damage Index (ACR-DI) was used to document the damage in each patient. The total SLICC/ACR-DI score ranged from 0 to 8. A higher DI score was found in hypertensive patients, compared to normotensive patients; and among those with positive anti-phospholipid antibodies, compared to those with negative anti-phospholipid antibodies. This difference was statistically significant (p < 0.01). Also, a higher DI score was found in cyclophosphamide users, compared to non-users; and in those with proteinuria and seizures, compared to those without; and the difference was statistically significant (p < 0.05). There was a significant positive correlation between the DI and patient age (p < 0.05). Damage in SLE cannot be prevented completely, as SLE disease is considered an aggressive disease treated by aggressive medications, but rheumatologists should try to minimize damage as much as possible to maintain the patients' health, functioning and general wellbeing. © The Author(s) 2016.
Griscom, A.; Jachens, R.C.
1989-01-01
Geologic and geophysical data for the San Andreas fault system north of San Francisco suggest that the eastern boundary of the Pacific plate migrated eastward from its presumed original position at the base of the continental slope to its present position along the San Andreas transform fault by means of a series of eastward jumps of the Mendocino triple junction. These eastward jumps total a distance of about 150 km since 29 Ma. Correlation of right-laterally displaced gravity and magnetic anomalies that now have components at San Francisco and on the shelf north of Point Arena indicates that the presently active strand of the San Andreas fault north of the San Francisco peninsula formed recently at about 5 Ma when the triple junction jumped eastward a minimum of 100 km to its present location at the north end of the San Andreas fault. -from Authors
Pimperl, Alexander F; Rodriguez, Hector P; Schmittdiel, Julie A; Shortell, Stephen M
2018-06-01
To identify positive deviant (PD) physician organizations of Accountable Care Organizations (ACOs) with robust performance management systems (PMSYS). Third National Survey of Physician Organizations (NSPO3, n = 1,398). Organizational and external factors from NSPO3 were analyzed. Linear regression estimated the association of internal and contextual factors on PMSYS. Two cutpoints (75th/90th percentiles) identified PDs with the largest residuals and highest PMSYS scores. A total of 65 and 41 PDs were identified using 75th and 90th percentiles cutpoints, respectively. The 90th percentile more strongly differentiated PDs from non-PDs. Having a high proportion of vulnerable patients appears to constrain PMSYS development. Our PD identification method increases the likelihood that PD organizations selected for in-depth inquiry are high-performing organizations that exceed expectations. © Health Research and Educational Trust.
Kolb, Alexander; Benca, Emir; Willegger, Madeleine; Puchner, Stephan E; Windhager, Reinhard; Chiari, Catharina
2017-06-01
The standardized sonographic hip screening according to Graf has increased reliability and comparability of measurements in the screening of developmental dysplasia of the hip (DDH). However, examiner dependent factors have been discussed to influence sonographic measurements. The objectives of this study were to examine the tolerance of the transducer positioning and to analyse the impact of transducer inclinations on Graf's hip grading system. Twenty-four hips in consecutive newborns were screened sonographically in combination with an optoelectronic motion capture system to trace transducer positions in space. Subsequently five defined inclinations of the transducer relative to Graf's neutral transducer position were analysed, giving a total of 144 sonographic images. We found a permissible transducer inclination in the axial plane of 8.8° to anterior and 8.1° to posterior. In the frontal plane we found a permissible inclination of 15.4° to caudal and 7.2° to cranial. The impact on the α-angle was significant for posterior-cranial (p < 0.001), cranial (p = 0.009), and caudal (p < 0.001) inclined transducer positions. The effect on the results according to Graf's grading system was significant for the caudal inclination of the transducer position (p < 0.001). Our findings show that the standardized plane defined by Graf's criteria allows notable inclinations of the transducer positions. Transducer inclinations show an impact on measurement results, which are clinically relevant. Those effects cannot be ruled out using Graf's ultrasound criteria alone. The examiner should pay attention to avoid transducer inclinations in the frontal plane and a combination of posterior and cranial inclination.
Tube and column agglutination technology for autocontrol testing.
Courtney, J E; Vincent, J L; Indrikovs, A J
2001-01-01
The incidence of positive autocontrol test results with column agglutination technology is a concern. This study investigates the incidence and significance of positive autocontrols in the ID Micro Typing System (gel) and the Gamma ReACT (ReACT). The study encompassed a total of 1021 randomly selected samples from patients and 95 samples from donors collected during 1 month. The autocontrol testing was carried out according to the manufacturer's instructions for the column agglutination tests. The tube method was carried out using low-ionic-strength solution (LISS). The direct antiglobulin test (DAT) was performed using the tube method, and further investigated with elution studies if warranted. Seventy-nine patient's samples (7.74%) had a positive autocontrol: the gel test, 72 (91.13%); ReACT, 21 (26.58%); and the tube method, 27 (34.18%). Of the 79 positive autocontrols, 44 samples had a negative DAT. Of the samples with positive DAT results, only one possessed a clinically significant antibody, anti-D. Moreover, the same sample also tested positive in all three methods. Column agglutination techniques have increased sensitivity for a positive autocontrol beyond the conventional tube method. However, ReACT and gel tests differ significantly in their frequency of positives. Investigation of the significance of a positive autocontrol in column agglutination technology when the conventional tube method is also positive is suggested.
Oztekin, Ceyda; Tezer, Esin
2009-01-01
This study investigated the role of sense of coherence and total physical activity in positive and negative affect. Participants were 376 (169 female, 206 male, and 1 missing value) student volunteers from different faculties of Middle East Technical University. Three questionnaires: Sense of Coherence Scale (SOC), Physical Activity Assessment Questionnaire (PAAQ), and Positive and Negative Affect Schedule (PANAS) were administered to the students together with the demographic information sheet. Two separate stepwise multiple linear regression analyses were conducted to examine the predictive power of sense of coherence and total physical activity on positive and negative affect scores. Results revealed that both sense of coherence and total physical activity predicted the positive affect whereas only the sense of coherence predicted the negative affect on university students. Findings are discussed in light of sense of coherence, physical activity, and positive and negative affect literature.
Performance Analysis of a Modular Small-Diamter Air Distribution System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, Andrew; Rudd, Armin
2016-03-01
This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air handler unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses anmore » additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.« less
Vitner, D; Paltieli, Y; Haberman, S; Gonen, R; Ville, Y; Nizard, J
2015-11-01
To assess the relationship between fetal head position and head station during labor, as measured using an ultrasound-based system, and the occurrence of occiput posterior (OP) position at delivery. This was an international prospective observational study including women who delivered between January 2009 and September 2013 in four centers: one in Brooklyn, NY, USA; one in Haifa, Israel; and two in Paris, France. We used an ultrasound-based system (LaborPro) to monitor fetal head station and position non-invasively throughout labor. We collected data on demographics, labor parameters and outcome. A total of 595 women were included. In 563 (94.6%) women, fetal head position at delivery was occiput anterior (OA), in 31 (5.2%) it was OP and in one (0.2%) it was occiput transverse. In 89% of pregnancies with intrapartum OP when fetal head station was above -2, the head position turned to OA at delivery; the equivalent figures were 74% and 63% OA at delivery when intrapartum OP was diagnosed at head stations of -2 to < 0, and 0 and below, respectively. Cesarean delivery was performed in 35% of pregnancies with fetal head in OP position at delivery, as opposed to 10% of those with non-OP position at delivery. On retrospective analysis, all deliveries in OP were already in OP at station -2 and below. In this first assessment of fetal head position at delivery according to fetal head position at various station levels, our data show that 100% of OP positions at delivery were already in OP position at station -2 and below. We did not observe rotation from a non-OP to an OP position from station -2 and below. Nearly two-thirds of fetuses in OP at station 0 and below will rotate to an OA position for delivery. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Renkawitz, Tobias; Tingart, Markus; Grifka, Joachim; Sendtner, Ernst; Kalteis, Thomas
2009-09-01
This article outlines the scientific basis and a state-of-the-art application of computer-assisted orthopedic surgery in total hip arthroplasty (THA) and provides a future perspective on this technology. Computer-assisted orthopedic surgery in primary THA has the potential to couple 3D simulations with real-time evaluations of surgical performance, which has brought these developments from the research laboratory all the way to clinical use. Nonimage- or imageless-based navigation systems without the need for additional pre- or intra-operative image acquisition have stood the test to significantly reduce the variability in positioning the acetabular component and have shown precise measurement of leg length and offset changes during THA. More recently, computer-assisted orthopedic surgery systems have opened a new frontier for accurate surgical practice in minimally invasive, tissue-preserving THA. The future generation of imageless navigation systems will switch from simple measurement tasks to real navigation tools. These software algorithms will consider the cup and stem as components of a coupled biomechanical system, navigating the orthopedic surgeon to find an optimized complementary component orientation rather than target values intraoperatively, and are expected to have a high impact on clinical practice and postoperative functionality in modern THA.
Hall, James R; Wiechmann, April R; Johnson, Leigh A; Edwards, Melissa; Barber, Robert C; Winter, A Scott; Singh, Meharvan; O'Bryant, Sid E
2013-01-01
Numerous serum and plasma based biomarkers of systemic inflammation have been linked to both neuropsychiatric disorders and Alzheimer's disease (AD). The present study investigated the relationship of clinical biomarkers of cardiovascular risk (cholesterol, triglycerides, and homocysteine) and a panel of markers of systemic inflammation (CRP, TNF-α, IL1-ra, IL-7, IL-10, IL-15, IL-18) and microvascular pathology (ICAM-1, VCAM-1) to neuropsychiatric symptoms in a sample with mild AD. Biomarker data was analyzed on a sample of 194 diagnosed with mild to moderate probable AD. The sample was composed of 127 females and 67 males. The presence of neuropsychiatric symptoms was gathered from interview with caretakers/family members using the Neuropsychiatric Inventory. For the total sample, IL-15, VCAM (vascular adhesion molecule), and triglycerides were significantly and negatively related to number of neuropsychiatric symptoms, and total cholesterol and homocysteine were positively related and as a group accounted for 16.1% of the variance. When stratified by gender, different patterns of significant biomarkers were found with relationships more robust for males for both total symptoms and symptom clusters. A combination of biomarkers of systemic inflammation, microvascular pathology, and clinical biomarkers of cardiovascular risk can account for a significant portion of the variance in the occurrence of neuropsychiatric symptoms in AD supporting a vascular and inflammatory component of psychiatric disorders found in AD. Gender differences suggest distinct impact of specific risks with total cholesterol, a measure of cardiovascular risk, being the strongest marker for males and IL-15, a marker of inflammation, being the strongest for females.
NASA Astrophysics Data System (ADS)
Kumar, Sanjay; Singh, Abhay Kumar
The dual frequency Global Positioning System (GPS) data recorded at Varanasi (geographic latitude 250, 16 N longitude 820, 59 E) and Kanpur (geographic latitude 260, 30 N longitude 800, 12 E) stations, near the equatorial ionosphere anomaly (EIA) in India, have been analyzed to retrieve total electron content (TEC). The daily peak value of vertical total electron content (VTEC) has been utilized to study the variability of EIA. Present paper studied monthly, seasonal and annual variations as well as solar and geomagnetic effects on EIA. It has been found that EIA yield their maximum values during the equinox months and minimum during summer and winter. The correlations of EIA with solar as well as geomagnetic indices have been also discussed. Key words: Total electron contents (TECs), EIA, GPS.
Secular variation and fluctuation of GPS Total Electron Content over Antarctica
NASA Astrophysics Data System (ADS)
Jin, Rui; Jin, Shuanggen
2013-01-01
The total electron content (TEC) is an important parameters in the Earth's ionosphere, related to various space weather and solar activities. However, understanding of the complex ionospheric environments is still a challenge due to the lack of direct observations, particularly in the polar areas, e.g., Antarctica. Now the Global Positioning System (GPS) can be used to retrieve total electron content (TEC) from dual-frequency observations. The continuous GPS observations in Antarctica provide a good opportunity to investigate ionospheric climatology. In this paper, the long-term variations and fluctuations of TEC over Antarctica are investigated from CODE global ionospheric maps (GIM) with a resolution of 2.5°×5° every two hours since 1998. The analysis shows significant seasonal and secular variations in the GPS TEC. Furthermore, the effects of TEC fluctuations are discussed.
Li, Qiang; Song, Ang; Peng, Wenjie; Jin, Zhenjiang; Müller, Werner E G; Wang, Xiaohong
2017-06-01
Aerobic anoxygenic phototrophic bacteria may play a particular role in carbon cycling of aquatic systems. However, little is known about the interaction between aerobic anoxygenic phototrophic bacteria and hydrochemistry in groundwater-surface water exchange systems of subtropical karst catchments. We carried out a detailed study on the abundance of aerobic anoxygenic phototrophic bacteria and bacterioplankton, hydrochemistry and taxonomy of bacterioplankton in the Maocun watershed, Southwest China, an area with karst geological background. Our results revealed that bacteria are the important contributors to total organic carbon source/sequestration in the groundwater-surface water of this area. The aerobic anoxygenic phototrophic bacteria, including β-Proteobacteria, also appear in the studied water system. In addition to that, the genus Polynucleobacter of the phototropic β-Proteobacteria shows a close link with those sampling sites by presenting bacterial origin organic carbon on CCA biplot and is found to be positively correlated with total nitrogen, dissolved oxygen and pH (r = 0.860, 0.747 and 0.813, respectively) in the Maocun watershed. The results suggest that Polynucleobacter might be involved in the production of organic carbon and might act as the negative feedback on global warming. © FEMS 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Frazier, O H; Tuzun, Egemen; Cohn, William E; Conger, Jeffrey L; Kadipasaoglu, Kamuran A
2006-01-01
Continuous-flow pumps are small, simple, and respond physiologically to input variations, making them potentially ideal for total heart replacement. However, the physiological effects of complete pulseless flow during long-term circulatory support without a cardiac interface or with complete cardiac exclusion have not been well studied. We evaluated the feasibility of dual continuous-flow pumps as a total artificial heart (TAH) in a chronic bovine model. Both ventricles of a 6-month-old Corriente crossbred calf were excised and sewing rings attached to the reinforced atrioventricular junctions. The inlet portions of 2 Jarvik 2000 pumps were positioned through their respective sewing rings at the mid-atrial level and the pulseless atrial reservoir connected end-to-end to the pulmonary artery and aorta. Pulseless systemic and pulmonary circulations were thereby achieved. Volume status was controlled, and systemic and pulmonary resistance were managed pharmacologically to keep mean arterial pressures at 100+/-10 mmHg (systemic) and 20+/-5 mmHg (pulmonary) and both left and right atrial pressures at 15+/-5 mmHg. The left pump speed was maintained at 14,000 rpm and its output autoregulated in response to variations in right pump flow, systemic and pulmonary pressures, fluid status, and activity level. Hemodynamics, end-organ function, and neurohormonal status remained normal. These results suggest the feasibility of using dual continuous-flow pumps as a TAH.
Story, Chandra R.; Knutson, Douglas; Whitt-Glover, Melicia C.
2016-01-01
Religious belief has been linked to a variety of positive mental and physical health outcomes. This exploratory study will address the relationship between religious involvement and social connectedness among African American women. Results from a physical activity intervention research project (N = 465) found that total religious support and social support were significantly negatively correlated with total religiosity, while total general social support was significantly positively correlated with total religious support. Overall, the study indicates that more research is needed on ways to encourage interaction between the positive dimensions of both religiosity and social support to bring about healthy behaviors. PMID:25673181
Granular dynamics under shear with deformable boundaries
NASA Astrophysics Data System (ADS)
Geller, Drew; Backhaus, Scott; Ecke, Robert
2015-03-01
Granular materials under shear develop complex patterns of stress as the result of granular positional rearrangements under an applied load. We consider the simple planar shear of a quasi two-dimensional granular material consisting of bi-dispersed nylon cylinders confined between deformable boundaries. The aspect ratio of the gap width to total system length is 50, and the ratio of particle diameter to gap width is about 10. This system, designed to model a long earthquake fault with long range elastic coupling through the plates, is an interesting model system for understanding effective granular friction because it essentially self tunes to the jamming condition owing to the hardness of the grains relative to that of the boundary material, a ratio of more than 1000 in elastic moduli. We measure the differential strain displacements of the plates, the inhomogeneous stress distribution in the plates, the positions and angular orientations of the individual grains, and the shear force, all as functions of the applied normal stress. There is significant stick-slip motion in this system that we quantify through our quantitative measurements of both the boundary and the grain motion, resulting in a good characterization of this sheared 2D hard sphere system.
Situation awareness system for Canada
NASA Astrophysics Data System (ADS)
Hill, Andrew
1999-07-01
Situation awareness encompasses a knowledge of orders, plans and current knowledge of friendly force actions. Knowing where you are and being able to transmit that information in near real-time to other friendly forces provides the ability to exercise precise command and control over those forces. With respect to current command and control using voice methods, between 40 percent and 60 percent of Combat Net Radio traffic relates to location reporting of some sort. Commanders at Battle Group and below spend, on average, 40 percent of their total time performing position and navigation related functions. The need to rapidly transfer own force location information throughout a force and to process the received information quickly, accurately and reliably provides the rationale for the requirement for an automated situation awareness system. This paper describes the Situation Awareness System (SAS) being developed by Computing Devices Canada for the Canadian Department of National Defence as a component of the Position Determination and Navigation for Land Forces program. The SAS is being integrated with the Iris Tactical Command, Control, Communications System, which is also being developed by Computing Devices. The SAS software provides a core operating environment onto which command and control functionality can be easily added to produce general and specialist battlefield management systems.
Improved Speed Control System for the 87,000 HP Wind Tunnel Drive
NASA Technical Reports Server (NTRS)
Becks, Edward A.; Bencic, Timothy J.; Blumenthal, Philip Z.
1995-01-01
This paper describes the design, installation, and integrated systems tests for a new drive motor speed control system which was part of a recent rehab project for the NASA Lewis 8x6 Supersonic Wind Tunnel. The tunnel drive consists of three mechanically-coupled 29,000 HP wound rotor induction motors driving an axial flow compressor. Liquid rheostats are used to vary the impedance of the rotor circuits, thus varying the speed of the drive system. The new design utilizes a distributed digital control system with a dual touch screen CRT operator console to provide alarm monitoring, logging, and trending. The liquid rheostats are driven by brushtype servomotor systems with magnetostrictive linear displacement transducers used for position feedback. The new system achieved all goals for speed variations with load, motor load balance, and control of total power.
Improved speed control system for the 87,000 HP wind tunnel drive
NASA Astrophysics Data System (ADS)
Becks, Edward A.; Bencic, Timothy J.; Blumenthal, Philip Z.
1995-01-01
This paper describes the design, installation, and integrated systems tests for a new drive motor speed control system which was part of a recent rehab project for the NASA Lewis 8x6 Supersonic Wind Tunnel. The tunnel drive consists of three mechanically-coupled 29,000 HP wound rotor induction motors driving an axial flow compressor. Liquid rheostats are used to vary the impedance of the rotor circuits, thus varying the speed of the drive system. The new design utilizes a distributed digital control system with a dual touch screen CRT operator console to provide alarm monitoring, logging, and trending. The liquid rheostats are driven by brushtype servomotor systems with magnetostrictive linear displacement transducers used for position feedback. The new system achieved all goals for speed variations with load, motor load balance, and control of total power.
Alexander, Nathalie; Strutzenberger, Gerda; Ameshofer, Lisa Maria; Schwameder, Hermann
2017-08-16
Work performance and individual joint contribution to total work are important information for creating training protocols, but were not assessed so far for sloped walking. Therefore, the purpose of this study was to analyze lower limb joint work and joint contribution of the hip, knee and ankle to total lower limb work during sloped walking in a healthy population. Eighteen male participants (27.0±4.7yrs, 1.80±0.05m, 74.5±8.2kg) walked on an instrumented ramp at inclination angles of 0°, ±6°, ±12° and ±18° at 1.1m/s. Kinematic and kinetic data were captured using a motion-capture system (Vicon) and two force plates (AMTI). Joint power curves, joint work (positive, negative, absolute) and each joint's contribution to total lower limb work were analyzed throughout the stance phase using an ANOVA with repeated measures. With increasing inclination positive joint work increased for the ankle and hip joint and in total during uphill walking. Negative joint work increased for each joint and in total work during downhill walking. Absolute work was increased during both uphill (all joints) and downhill (ankle & knee) walking. Knee joint contribution to total negative and absolute work increased during downhill walking while hip and ankle contributions decreased. This study identified, that, when switching from level to a 6° and from 6° to a 12° inclination the gain of individual joint work is more pronounced compared to switching from 12° to an 18° inclination. The results might be used for training recommendations and specific training intervention with respect to sloped walking. Copyright © 2017 Elsevier Ltd. All rights reserved.
Colen, David L; Carney, Martin J; Shubinets, Valeriy; Lanni, Michael A; Liu, Tiffany; Levin, L Scott; Lee, Gwo-Chin; Kovach, Stephen J
2018-04-01
Total knee arthroplasty is a common orthopedic procedure in the United States and complications can be devastating. Soft-tissue compromise or joint infection may cause failure of prosthesis requiring knee fusion or amputation. The role of a plastic surgeon in total knee arthroplasty is critical for cases requiring optimization of the soft-tissue envelope. The purpose of this study was to elucidate factors associated with total knee arthroplasty salvage following complications and clarify principles of reconstruction to optimize outcomes. A retrospective review of patients requiring soft-tissue reconstruction performed by the senior author after total knee arthroplasty over 8 years was completed. Logistic regression and Fisher's exact tests determined factors associated with the primary outcome, prosthesis salvage versus knee fusion or amputation. Seventy-three knees in 71 patients required soft-tissue reconstruction (mean follow-up, 1.8 years), with a salvage rate of 61.1 percent, mostly using medial gastrocnemius flaps. Patients referred to our institution with complicated periprosthetic wounds were significantly more likely to lose their knee prosthesis than patients treated only within our system. Patients with multiple prior knee operations before definitive soft-tissue reconstruction had significantly decreased rates of prosthesis salvage and an increased risk of amputation. Knee salvage significantly decreased with positive joint cultures (Gram-negative greater than Gram-positive organisms) and particularly at the time of definitive reconstruction, which also trended toward an increased risk of amputation. In revision total knee arthroplasty, prompt soft-tissue reconstruction improves the likelihood of success, and protracted surgical courses and contamination increase failure and amputations. The authors show a benefit to involving plastic surgeons early in the course of total knee arthroplasty complications to optimize genicular soft tissues. Therapeutic, III.
One dimensional two-body collisions experiment based on LabVIEW interface with Arduino
NASA Astrophysics Data System (ADS)
Saphet, Parinya; Tong-on, Anusorn; Thepnurat, Meechai
2017-09-01
The purpose of this work is to build a physics lab apparatus that is modern, low-cost and simple. In one dimensional two-body collisions experiment, we used the Arduino UNO R3 as a data acquisition system which was controlled by LabVIEW program. The photogate sensors were designed using LED and LDR to measure position as a function of the time. Aluminium frame houseware and blower were used for the air track system. In both totally inelastic and elastic collision experiments, the results of momentum and energy conservation are in good agreement with the theoretical calculations.
Total energy based flight control system
NASA Technical Reports Server (NTRS)
Lambregts, Antonius A. (Inventor)
1985-01-01
An integrated aircraft longitudinal flight control system uses a generalized thrust and elevator command computation (38), which accepts flight path angle, longitudinal acceleration command signals, along with associated feedback signals, to form energy rate error (20) and energy rate distribution error (18) signals. The engine thrust command is developed (22) as a function of the energy rate distribution error and the elevator position command is developed (26) as a function of the energy distribution error. For any vertical flight path and speed mode the outerloop errors are normalized (30, 34) to produce flight path angle and longitudinal acceleration commands. The system provides decoupled flight path and speed control for all control modes previously provided by the longitudinal autopilot, autothrottle and flight management systems.
[On evaluating the robot-based experimental system for biomechanical experiment of human knee].
Deng, Guoyong; Tian, Lianfang; Bai, Bo; Sun, Hui
2010-02-01
This is a report on how we use the hybrid force-displacement control method to load the human knee and analyze the effect and value of our robot experimental system through the biomechanical experiments of total meniscal resection of human knee. The whole robot control system can load continuously on the specimens, thus overcoming the shortcomings of the traditional loading methods which can only load discretely. In the meantime, by using the robot-based testing system, the force (torque) of the specimens and the spatial position under the force can be measured in real-time, which overcomes the shortcomings caused by the separation of force (torque) measurement from displacement measurement and so greatly improves the measurement accuracy.
Atmospheric aerosol profiling with a bistatic imaging lidar system.
Barnes, John E; Sharma, N C Parikh; Kaplan, Trevor B
2007-05-20
Atmospheric aerosols have been profiled using a simple, imaging, bistatic lidar system. A vertical laser beam is imaged onto a charge-coupled-device camera from the ground to the zenith with a wide-angle lens (CLidar). The altitudes are derived geometrically from the position of the camera and laser with submeter resolution near the ground. The system requires no overlap correction needed in monostatic lidar systems and needs a much smaller dynamic range. Nighttime measurements of both molecular and aerosol scattering were made at Mauna Loa Observatory. The CLidar aerosol total scatter compares very well with a nephelometer measuring at 10 m above the ground. The results build on earlier work that compared purely molecular scattered light to theory, and detail instrument improvements.
NASA Astrophysics Data System (ADS)
Mahalakshmi; Murugesan, R.
2018-04-01
This paper regards with the minimization of total cost of Greenhouse Gas (GHG) efficiency in Automated Storage and Retrieval System (AS/RS). A mathematical model is constructed based on tax cost, penalty cost and discount cost of GHG emission of AS/RS. A two stage algorithm namely positive selection based clonal selection principle (PSBCSP) is used to find the optimal solution of the constructed model. In the first stage positive selection principle is used to reduce the search space of the optimal solution by fixing a threshold value. In the later stage clonal selection principle is used to generate best solutions. The obtained results are compared with other existing algorithms in the literature, which shows that the proposed algorithm yields a better result compared to others.
A hollow cathode neutralizer for a 30-cm diameter bombardment thruster
NASA Technical Reports Server (NTRS)
Bechtel, R. T.
1973-01-01
Recent improvements in overall thrustor performance have imposed new constraints on neutralizer performance. The use of compensated grid extraction system requires a re-evaluation of neutralizer position. In addition a suitable control logic for the neutralizer has proven difficult. A series of tests were conducted to determine what effect neutralizer cathode geometry has on performance. The parameters investigated included orifice diameter and length, and cathode diameter. Similar tests investigated open and enclosed keeper geometries. Neutralizer position tests with compensated grids suggest positions approximately 10 cm from the accelerator and radially out of the beam envelope should result in satisfactory performance and long life. Finally operation at keeper currents of 1.5 amp has resulted in lower total neutralizer power, the elimination of tip heater power, and suitable closed loop control of the neutralizer vaporizer.
NASA Astrophysics Data System (ADS)
Ko, Woo Seok; Darwish, Naser; Gratton, Enrico; Kim, Soo Hyun
2005-04-01
We measure the concentration of oxy-, deoxy- and total hemoglobin by using the frequency-domain, near-infrared spectroscopy(NIRS) scanner. It is a non-invasive instrument that can provide real-time measurements of the changes in concentration. It can provide a diagnostic tool for the study of the brain in infants and children. However, it is difficult to apply it to the baby's head because of the contact of the probe on the soft baby's head. Therefore, we suggest the NIRS scanning system that can track the baby' head movement and detect NIRS parameters on the same position of the head. This system has three key components. The vision system performs the pattern matching for tracking the head by using the normalized cross correlation method with the target as a cross-line on the head during the diagnostic experiment. We can use the change of the position of the baby's head to re-target the light by the scanning system that uses four laser sources, a wavelength selector, and an x-y scanner. The detector system analyzes the resulting signal from the head using the diffusion model. Therefore, NIRS scanning system can provide a diagnostic tool to measure the changes of the NIRS parameters for the study of the baby's brain.
Fabry, Christian; Kaehler, Michael; Herrmann, Sven; Woernle, Christoph; Bader, Rainer
2014-01-01
Tripolar systems have been implanted to reduce the risk of recurrent dislocation. However, there is little known about the dynamic behavior of tripolar hip endoprostheses under daily life conditions and achieved joint stability. Hence, the objective of this biomechanical study was to examine the in vivo dynamics and dislocation behavior of two types of tripolar systems compared to a standard total hip replacement (THR) with the same outer head diameter. Several load cases of daily life activities were applied to an eccentric and a concentric tripolar system by an industrial robot. During testing, the motion of the intermediate component was measured using a stereo camera system. Additionally, their behavior under different dislocation scenarios was investigated in comparison to a standard THR. For the eccentric tripolar system, the intermediate component demonstrated the shifting into moderate valgus-positions, regardless of the type of movement. This implant showed the highest resisting torque against dislocation in combination with a large range of motion. In contrast, the concentric tripolar system tended to remain in varus-positions and was primarily moved after stem contact. According to the results, eccentric tripolar systems can work well under in vivo conditions and increase hip joint stability in comparison to standard THRs. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
A low-cost method for estimating energy expenditure during soccer refereeing.
Ardigò, Luca Paolo; Padulo, Johnny; Zuliani, Andrea; Capelli, Carlo
2015-01-01
This study aimed to apply a validated bioenergetics model of sprint running to recordings obtained from commercial basic high-sensitivity global positioning system receivers to estimate energy expenditure and physical activity variables during soccer refereeing. We studied five Italian fifth division referees during 20 official matches while carrying the receivers. By applying the model to the recorded speed and acceleration data, we calculated energy consumption during activity, mass-normalised total energy consumption, total distance, metabolically equivalent distance and their ratio over the entire match and the two halves. Main results were as follows: (match) energy consumption = 4729 ± 608 kJ, mass normalised total energy consumption = 74 ± 8 kJ · kg(-1), total distance = 13,112 ± 1225 m, metabolically equivalent distance = 13,788 ± 1151 m and metabolically equivalent/total distance = 1.05 ± 0.05. By using a very low-cost device, it is possible to estimate the energy expenditure of soccer refereeing. The provided predicting mass-normalised total energy consumption versus total distance equation can supply information about soccer refereeing energy demand.
Recent Developments in Balloon Support Instrumentation at TIFR Balloon Facility, Hyderabad.
NASA Astrophysics Data System (ADS)
Vasudevan, Rajagopalan
2012-07-01
The Balloon Facility of Tata Institute of Fundamental Research has been conducting stratospheric balloon flights regularly for various experiments in Space Astronomy and Atmospheric Sciences. A continuous improvement in Balloon flight Support instrumentation by the Control Instrumentation Group to keep in space with the growing complexities of the scientific payloads have contributed to the total success of balloon flights conducted recently. Recent improvements in display of Balloon position during balloon flight by showing on real time the balloon GPS position against Google TM maps is of immense help in selecting the right spot for payload landing and safe recovery . For further speeding up the payload recovery process, a new GPS-GSM payload system has been developed which gives SMS of the payload position information to the recovery team on their cell phones. On parallel footing, a new GPS- VHF system has been developed using GPS and Radio Modems for Balloon Tracking and also for obtaining the payload impact point. On the Telecommand side, a single board Telecommand/ Timer weighing less than 2 Kg has been specially developed for use in the mesosphere balloon test flight. The interference on the existing Short Range Telemetry System has been eliminated by introducing a Band Pass Filter and LNA in the Receiving system of the modules, thereby enhancing its reliability. In this paper , we present the details of the above mentioned developments.
Regional positioning using a low Earth orbit satellite constellation
NASA Astrophysics Data System (ADS)
Shtark, Tomer; Gurfil, Pini
2018-02-01
Global and regional satellite navigation systems are constellations orbiting the Earth and transmitting radio signals for determining position and velocity of users around the globe. The state-of-the-art navigation satellite systems are located in medium Earth orbits and geosynchronous Earth orbits and are characterized by high launching, building and maintenance costs. For applications that require only regional coverage, the continuous and global coverage that existing systems provide may be unnecessary. Thus, a nano-satellites-based regional navigation satellite system in Low Earth Orbit (LEO), with significantly reduced launching, building and maintenance costs, can be considered. Thus, this paper is aimed at developing a LEO constellation optimization and design method, using genetic algorithms and gradient-based optimization. The preliminary results of this study include 268 LEO constellations, aimed at regional navigation in an approximately 1000 km × 1000 km area centered at the geographic coordinates [30, 30] degrees. The constellations performance is examined using simulations, and the figures of merit include total coverage time, revisit time, and geometric dilution of precision (GDOP) percentiles. The GDOP is a quantity that determines the positioning solution accuracy and solely depends on the spatial geometry of the satellites. Whereas the optimization method takes into account only the Earth's second zonal harmonic coefficient, the simulations include the Earth's gravitational field with zonal and tesseral harmonics up to degree 10 and order 10, Solar radiation pressure, drag, and the lunisolar gravitational perturbation.
An Integration of the Turbojet and Single-Throat Ramjet
NASA Technical Reports Server (NTRS)
Trefny, C. J.; Benson, T. J.
1995-01-01
A turbine-engine-based hybrid propulsion system is described. Turbojet engines are integrated with a single-throat ramjet so as to minimize variable geometry and eliminate redundant propulsion components. The result is a simple, lightweight system that is operable from takeoff to high Mach numbers. Non-afterburning turbojets are mounted within the ramjet duct. They exhaust through a converging-diverging (C-D) nozzle into a common ramjet burner section. At low speed the ejector effect of the C-D nozzle aerodynamically isolates the relatively high pressure turbojet exhaust stream from the ramjet duct. As the Mach number increases, and the turbojet pressure ratio diminishes, the system is biased naturally toward ramjet operation. The common ramjet burner is fueled with hydrogen and thermally choked, thus avoiding the weight and complexity of a variable geometry, split-flow exhaust system. The mixed-compression supersonic inlet and subsonic diffuser are also common to both the turbojet and ramjet cycles. As the compressor face total temperature limit is approached, a two-position flap within the inlet is actuated, which closes off the turbojet inlet and provides increased internal contraction for ramjet operation. Similar actuation of the turbojet C-D nozzle flap completes the enclosure of the turbojet. Performance of the hybrid system is compared herein to that of the discrete turbojet and ramjet engines from takeoff to Mach 6. The specific impulse of the hybrid system falls below that of the non-integrated turbojet and ramjet because of ejector and Rayleigh losses. Unlike the discrete turbojet or ramjet however, the hybrid system produces thrust over the entire Mach number range. An alternate mode of operation for takeoff and low speed is also described. In this mode the C-D nozzle flap is deflected to a third position, which closes off the ramjet duct and eliminates the ejector total pressure loss.
Valve Health Monitoring System Utilizing Smart Instrumentation
NASA Technical Reports Server (NTRS)
Jensen, Scott L.; Drouant, George J.
2006-01-01
The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are cryogenic cycles, total cycles, inlet temperature, body temperature torsional strain, linear bonnet strain, preload position, total travel and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commission's requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 enclosures are used to house the base-station
Valve health monitoring system utilizing smart instrumentation
NASA Astrophysics Data System (ADS)
Jensen, Scott L.; Drouant, George J.
2006-05-01
The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are: cryogenic cycles, total cycles, inlet temperature, outlet temperature, body temperature, torsional strain, linear bonnet strain, preload position, total travel, and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commissions requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates related data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 Enclosures are used to house the base-station.
Sleep deprivation affects reactivity to positive but not negative stimuli.
Pilcher, June J; Callan, Christina; Posey, J Laura
2015-12-01
The current study examined the effects of partial and total sleep deprivation on emotional reactivity. Twenty-eight partially sleep-deprived participants and 31 totally sleep-deprived participants rated their valence and arousal responses to positive and negative pictures across four testing sessions during the day following partial sleep deprivation or during the night under total sleep deprivation. The results suggest that valence and arousal ratings decreased under both sleep deprivation conditions. In addition, partial and total sleep deprivation had a greater negative effect on positive events than negative events. These results suggest that sleep-deprived persons are more likely to respond less to positive events than negative events. One explanation for the current findings is that negative events could elicit more attentive behavior and thus stable responding under sleep deprivation conditions. As such, sleep deprivation could impact reactivity to emotional stimuli through automated attentional and self-regulatory processes. Copyright © 2015 Elsevier Inc. All rights reserved.
Murphy, Darby S; Lee, Xia; Larson, Scott R; Johnson, Diep K Hoang; Loo, Theoren; Paskewitz, Susan M
2017-04-01
Ehrlichiosis and anaplasmosis are important emerging tickborne zoonoses that affect both humans and animals. Knowledge of the geographic distribution and prevalence of Ehrlichia spp. and Anaplasma phagocytophilum in Wisconsin is important information as a baseline for future comparisons. Reported human cases between 2009 and 2015 were identified using the Wisconsin Electronic Disease Surveillance System (WEDSS) and mapped by county of residence. Vector surveillance was established using ticks collected from animals by partners, including veterinary medical clinics, domestic animal shelters, and wildlife rehabilitation centers from 40 Wisconsin counties. A total of 1835 Ixodes scapularis tick specimens (larvae, nymphs, and adults) were collected from 18 different domestic and wildlife species from July 2011 to November 2015. An additional 1136 nymphs were collected by drag sampling at 23 locations in 19 counties in 2015. A real-time PCR assay that detects and distinguishes several Ehrlichia species, including a pathogenic Ehrlichia muris-like agent (EMLA), and A. phagocytophilum was performed on adult and nymphal ticks. A total of 757 I. scapularis ticks (predominately adults) were tested from animal collections, with 67 (8.9%) individuals positive for A. phagocytophilum and 22 (2.9%) positive for EMLA DNA. Of the 1150 questing nymphs, 62 (5.4%) were positive for A. phagocytophilum and 10 (0.9%) were positive for EMLA DNA. Specimens of I. scapularis that were positive for A. phagocytophilum were found in 27 of the 33 counties surveyed. Specimens that were positive for EMLA were less common and were found in nine counties. This study provides the first statewide survey of I. scapularis ticks for these pathogens and indicates that the risk of human exposure is widely distributed.
Gómez, José Manuel; Maravall, Francisco Javier; Gómez, Núria; Navarro, Miguel Angel; Casamitjana, Roser; Soler, Juan
2003-02-01
Leptin secretion is influenced by many factors and the GH/IGF axis plays an important role in the regulation of body composition, but the physiological interactions between leptin and the IGF-I system remain unknown. In this study we investigated the relationship between leptin, the IGF-I system, and sex, age, anthropometric and body composition variables in a group of healthy adults randomly selected. A cross-sectional study. The study included 268 subjects, representative of the whole population of the city of L'Hospitalet de Llobregat in sex and age distribution: 134 men aged 41.4 years, range 15-70 years; and 134 women, aged 40.7 years, range 15-70 years. Body mass index (BMI) was calculated, and body composition was determined by using a bioelectrical impedance analyser. Serum leptin concentrations were determined by using a radioimmunoassay (RIA). Serum total IGF-I concentrations, after acid-ethanol extraction, were also measured by RIA. Serum free IGF-I concentrations were determined by an enzymoimmunometric assay. Serum IGFBP3 concentrations were determined by RIA. Plasma basal TSH concentrations were determined by a specific electrochemiluminescence assay. In men the BMI was similar in all decades and waist/hip ratio increased in the last three decades. Fat-free mass decreased by decade. We observed an increase in leptin in the fourth decade with a decrease in IGF-I, free IGF-I and IGFBP3 throughout the decades. Basal TSH showed an increase in the last two decades. In women, BMI, waist/hip ratio and fat mass increased significantly in the last decades. Leptin concentrations increased in the last decades and total IGF-I, free IGF-I and IGFBP3 decreased by decade without changes in basal TSH concentration. In men, there was a positive correlation between leptin and BMI, waist/hip ratio, total body water, fat-free mass and fat mass, and these anthropometric and body composition variables showed a negative correlation with free IGF-I and IGFBP3, without any correlation with total IGF-I. In women, there was a positive correlation between leptin and BMI, waist/hip ratio, total body water, fat-free mass, and fat mass, which showed a negative correlation with total IGF-I and IGFBP3, without any correlation with free IGF-I. In men, total IGF-I was negatively correlated with waist/hip ratio without any correlation with the other variables and free IGF-I was negatively correlated with BMI and waist/hip ratio, and IGFBP3 did not show any correlation. In women, total IGF-I, free IGF-I and IGFBP3 were negatively correlated with BMI, waist/hip ratio and fat mass. The multiple linear regression analysis produced a model that explained 60.5% of leptin variability in men and 40% in women. Notably, only age, BMI, fat mass and waist/hip ratio brought an independent significant contribution to leptin variability. The final model also explained 28.2% and 60.4% of total IGF-I variability and 17.2% and 27.4% of free IGF-I variability in men and women, respectively. Age and leptin contributed to free IGF-I variability in men, and age and fat mass were significantly and independently associated with total IGF-I in women. In this well-characterized population of controls randomly selected without chronic disease or drug administration and with biochemically confirmed euthyroidism, we found that both men and women had a significant correlation between leptin levels and the IGF-I system, and anthropometric and body composition variables, but that leptin did not regulate the IGF-I system, and that the IGF-I system did not regulate leptin synthesis and secretion.
McCue, Michael J
2007-01-01
National benchmark data for 2002 indicate that large rural for-profit hospitals have a median cash flow margin of 19.5% compared to 9.2% for their nonprofit counterparts. This study aims to gain insight regarding the driving factors behind the high cash flow performance of large rural for-profit hospitals. Using 3 annual periods of Centers for Medicare and Medicaid cost report data with the last fiscal year ending between September 30, 2002, and August 30, 2003, the study found a cash flow margin of 21.5% for the large rural for-profit hospitals. All these facilities were owned by hospital management companies. To assess their underlying market, operational, and mission factors, these hospitals were compared to a similar comparison group of large rural nonprofit hospitals that are system owned and have positive cash flows. Using logistic regression analysis, the study found lower operating expense per adjusted discharge and salary expense as a percentage of total operating expense among large rural for-profit, system-owned hospitals with positive cash flows relative to nonprofits with similar traits. Overall, the findings of this study reflect how these for-profit hospitals, which are owned by hospital management companies, focus on controlling their labor costs as well as operating costs per discharge in order to achieve a greater positive cash flow position.
Asemi, Zatollah; Jazayeri, Shima; Najafi, Mohammad; Samimi, Mansooreh; Shidfar, Farzad; Tabassi, Zohreh; Shahaboddin, Mohamadesmaeil; Esmaillzadeh, Ahmad
2013-05-01
Increased levels of pro-inflammatory factors, markers of oxidative stress and lipid profiles are known to be associated with several complications. The aim of this study was to determine the association of markers of systemic inflammation, oxidative stress and lipid profiles with insulin resistance in pregnant women in Kashan, Iran. In a cross-sectional study, serum high sensitivity C-reactive protein (hs-CRP), tumor necrosis factor-alpha (TNF-α), fasting plasma glucose (FPG), serum insulin, 8-oxo-7, 8-dihydroguanine (8-oxo-G), total cholesterol, triglyceride, High density lipoprotein-cholesterol (HDL-cholesterol), and plasma total antioxidant capacity (TAC) were measured among 89 primigravida singleton pregnant women aged 18-30 years at 24-28 weeks of gestation. Pearson's correlation and multiple linear regressions were used to assess their relationships with homeostatic model assessment of insulin resistance (HOMA-IR). We found that among biochemical indicators of pregnant women, serum hs-CRP and total cholesterol levels were positively correlated with HOMA-IR (β = 0.05, P = 0.006 for hs-CRP and β = 0.006, P = 0.006 for total cholesterol). These associations remained significant even after mutual effect of other biochemical indicators were controlled (β = 0.04, P = 0.01 for hs-CRP and β = 0.007, P = 0.02 for total cholesterol). Further adjustment for body mass index made the association of hs-CRP and HOMA-IR disappeared; however, the relationship for total cholesterol remained statistically significant. Our findings showed that serum total cholesterol is independently correlated with HOMA-IR score. Further studies are needed to confirm our findings.
Global Ionosphere Perturbations Monitored by the Worldwide GPS Network
NASA Technical Reports Server (NTRS)
Ho, C. M.; Manucci, A. T.; Lindqwister, U. J.; Pi, X.
1996-01-01
For the first time, measurements from the Global Positioning System (GPS) worldwide network are employed to study the global ionospheric total electron content(TEC) changes during a magnetic storm (November 26, 1994). These measurements are obtained from more than 60 world-wide GPS stations which continuously receive dual-frequency signals. Based on the delays of the signals, we have generated high resolution global ionospheric maps (GIM) of TEC at 15 minute intervals. Using a differential method comparing storm time maps with quiet time maps, we find that significant TEC increases (the positive effect ) are the major feature in the winter hemisphere during this storm (the maximum percent change relative to quiet times is about 150 percent).
Kevern, Mark A.; Beecher, Michael; Rao, Smita
2014-01-01
Context: Athletes who participate in throwing and racket sports consistently demonstrate adaptive changes in glenohumeral-joint internal and external rotation in the dominant arm. Measurements of these motions have demonstrated excellent intrarater and poor interrater reliability. Objective: To determine intrarater reliability, interrater reliability, and standard error of measurement for shoulder internal rotation, external rotation, and total arc of motion using an inclinometer in 3 testing procedures in National Collegiate Athletic Association Division I baseball and softball athletes. Design: Cross-sectional study. Setting: Athletic department. Patients or Other Participants Thirty-eight players participated in the study. Shoulder internal rotation, external rotation, and total arc of motion were measured by 2 investigators in 3 test positions. The standard supine position was compared with a side-lying test position, as well as a supine test position without examiner overpressure. Results: Excellent intrarater reliability was noted for all 3 test positions and ranges of motion, with intraclass correlation coefficient values ranging from 0.93 to 0.99. Results for interrater reliability were less favorable. Reliability for internal rotation was highest in the side-lying position (0.68) and reliability for external rotation and total arc was highest in the supine-without-overpressure position (0.774 and 0.713, respectively). The supine-with-overpressure position yielded the lowest interrater reliability results in all positions. The side-lying position had the most consistent results, with very little variation among intraclass correlation coefficient values for the various test positions. Conclusions: The results of our study clearly indicate that the side-lying test procedure is of equal or greater value than the traditional supine-with-overpressure method. PMID:25188316
Bosch, Tyler A; Carbuhn, Aaron; Stanforth, Philip R; Oliver, Jonathan M; Keller, Kathryn A; Dengel, Donald R
2017-03-08
The purpose of the present study was to generate normative data for total and regional body composition in Division 1 collegiate football players using dual-energy X-ray absorptiometry (DXA) and examine positional differences in total and regional measurements. Data was used from the Consortium of College Athlete Research (C-CAR) group. Four hundred-sixty-seven players were included in this study. Height, weight, total and regional fat mass, lean mass and bone mineral density were measured in each athlete in the preseason (June-August). Players were categorized by their offensive or defensive position for comparisons. Linemen tended to have the higher fat and lean mass measures (p<0.05 for all) compared to other positions. Positions that mirror each other (ex. Linemen) had similar body composition and body ratios. All positions were classified as overweight or obese based on BMI (>25 kg/m), yet other than offensive and defensive linemen, all positions had healthy percent body fat (13-20%) and low visceral fat mass (<500 g). The data presented here provide normative positional data for total and regional fat mass, lean mass, and bone density in Division 1 collegiate football players. Player position had a significant effect on body composition measures and is likely associated with on-field positional requirements. From a player health perspective, even though all positions had relatively high BMI values, the majority of positions had relatively low body fat and visceral fat, which is important for the health of players during and after their playing career. The increased accuracy and reliability of DXA provides greater information regarding positional differences in college football players compared to other methods.
Detector system dose verification comparisons for arc therapy: couch vs. gantry mount
Manikandan, Arjunan; Nandy, Maitreyee; Sureka, Chandra Sekaran; Gossman, Michael S.; Sujatha, Nadendla; Rajendran, Vivek Thirupathur
2014-01-01
The aim of this study was to assess the performance of a gantry‐mounted detector system and a couch set detector system using a systematic multileaf collimator positional error manually introduced for volumetric‐modulated arc therapy. Four head and neck and esophagus VMAT plans were evaluated by measurement using an electronic portal imaging device and an ion chamber array. Each plan was copied and duplicated with a 1 mm systematic MLC positional error in the left leaf bank. Direct comparison of measurements for plans with and without the error permitted observational characteristics for quality assurance performance between detectors. A total of 48 different plans were evaluated for this testing. The mean percentage planar dose differences required to satisfy a 95% match between plans with and without the MLCPE were 5.2% ± 0.5% for the chamber array with gantry motion, 8.12% ± 1.04% for the chamber array with a static gantry at 0°, and 10.9% ± 1.4% for the EPID with gantry motion. It was observed that the EPID was less accurate due to overresponse of the MLCPE in the left leaf bank. The EPID always images bank‐A on the ipsilateral side of the detector, whereas for a chamber array or for a patient, that bank changes as it crosses the ‐90° or +90° position. A couch set detector system can reproduce the TPS calculated values most consistently. We recommend it as the most reliable patient specific QA system for MLC position error testing. This research is highlighted by the finding of up to 12.7% dose variation for H/N and esophagus cases for VMAT delivery, where the mere source of error was the stated clinically acceptability of 1 mm MLC position deviation of TG‐142. PACS numbers: 87.56.‐v, 87.55.‐x, 07.57.KP, 29.40.‐n, 85.25.Pb PMID:24892330
Precise CCD positions of Himalia using Gaia DR1 in 2015-2016
NASA Astrophysics Data System (ADS)
Peng, H. W.; Peng, Q. Y.; Wang, N.
2017-05-01
In order to obtain high-precision CCD positions of Himalia, the sixth Jovian satellite, a total of 598 CCD observations have been obtained during the years 2015-2016. The observations were made by using the 2.4 and 1 m telescopes administered by Yunnan Observatories over 27 nights. Several factors that would influence the positional precision of Himalia were analysed, including the reference star catalogue used, the geometric distortion and the phase effect. By taking advantage of its unprecedented positional precision, the recently released catalogue Gaia Data Release 1 was chosen to match reference stars in the CCD frames of both Himalia and open clusters, which were observed for deriving the geometric distortion. The latest version of sofa library was used to calculate the positions of reference stars. The theoretical positions of Himalia were retrieved from the Jet Propulsion Laboratory Horizons System that includes the satellite ephemeris JUP300, while the positions of Jupiter were based on the planetary ephemeris DE431. Our results showed that the means of observed minus computed (O - C) residuals are 0.071 and -0.001 arcsec in right ascension and declination, respectively. Their standard deviations are estimated at about 0.03 arcsec in each direction.
Jennifer N. Phelan; Paramita Sinha; George Van Houtven; Marion Deerhake; Randall G. Waite; Anne W. Rea; Ginger M. Tennant
2012-01-01
Total nitrogen (N) and sulfur (S) deposition in forest systems can have either positive or negative impacts on tree growth. The growth of many forests in North America is limited by N availability. Therefore, N fertilization is often a key component of forest management, and in areas of N deposition, tree growth may be stimulated. However, N additions can sometimes be...
System for measuring multiphase flow using multiple pressure differentials
Fincke, James R.
2003-01-01
An improved method and system for measuring a multi-phase flow in a pressure flow meter. An extended throat venturi is used and pressure of the multi-phase flow is measured at three or more positions in the venturi, which define two or more pressure differentials in the flow conduit. The differential pressures are then used to calculate the mass flow of the gas phase, the total mass flow, and the liquid phase. The system for determining the mass flow of the high void fraction fluid flow and the gas flow includes taking into account a pressure drop experienced by the gas phase due to work performed by the gas phase in accelerating the liquid phase.
System and method for bidirectional flow and controlling fluid flow in a conduit
Ortiz, M.G.
1999-03-23
A system for measuring bidirectional flow, including backflow, of fluid in a conduit is disclosed. The system utilizes a structural mechanism to create a pressure differential in the conduit. Pressure sensors are positioned upstream from the mechanism, at the mechanism, and downstream from the mechanism. Data from the pressure sensors are transmitted to a microprocessor or computer, and pressure differential detected between the pressure sensors is then used to calculate the backflow. Control signals may then be generated by the microprocessor or computer to shut off valves located in the conduit, upon the occurrence of backflow, or to control flow, total material dispersed, etc. in the conduit. 3 figs.
Operational Challenges In TDRS Post-Maneuver Orbit Determination
NASA Technical Reports Server (NTRS)
Laing, Jason; Myers, Jessica; Ward, Douglas; Lamb, Rivers
2015-01-01
The GSFC Flight Dynamics Facility (FDF) is responsible for daily and post maneuver orbit determination for the Tracking and Data Relay Satellite System (TDRSS). The most stringent requirement for this orbit determination is 75 meters total position accuracy (3-sigma) predicted over one day for Terra's onboard navigation system. To maintain an accurate solution onboard Terra, a solution is generated and provided by the FDF Four hours after a TDRS maneuver. A number of factors present challenges to this support, such as maneuver prediction uncertainty and potentially unreliable tracking from User satellities. Reliable support is provided by comparing an extended Kalman Filter (estimated using ODTK) against a Batch Least Squares system (estimated using GTDS).
Need for immunization against hepatotropic viruses in children with chronic liver disease.
Srivastava, Anshu; Mathias, Amrita; Yachha, Surender Kumar; Agarwal, Jaya; Aggarwal, Rakesh
2014-09-01
Infection with hepatotropic viruses is a common cause of acute deterioration and adverse outcome in children with chronic liver disease (CLD). Such superimposed infections may be preventable through vaccination. The present study aimed to evaluate the exposure rates of hepatitis A, B, and E viruses in children with CLD and suggest an optimal vaccination strategy. Children with CLD were prospectively evaluated with a demographic, clinical, and investigative proforma. Hepatitis B surface antigen positive cases were labeled as hepatitis B virus-CLD, and all other etiologies as non-HBV-related CLD. Patients were tested for exposure to hepatitis A (total anti-hepatitis A virus [HAV], immunoglobulin M anti-HAV), hepatitis B (hepatitis B surface antigen, total anti-hepatitis B core, anti-hepatitis B surface), and hepatitis E (IgG anti-hepatitis E virus). A total of 142 children with CLD (age 9.1 ± 3.7 years, 83 [58.5%] boys) were enrolled. A total of 3.5% (5/142) and 38.7% (55/142) had received HAV and HBV vaccines, respectively. A total of 134 (94.4%) were total anti-HAV positive including 5 postimmunization patients, with higher positivity in those older than 5 years (19/25 vs 115/117; P = 0.001). Of the 115 patients with non-HBV-related CLD, 45 (39.1%) had exposure to HBV (40 total anti-hepatitis B core positive and 5 anti-HBs positive without immunization). Only 28 of 142 (19.7%) patients were IgG anti-HEV positive, with no difference across age. A total of 90.8%, 39.1%, and 19.7% of children with CLD from the developing world are exposed to hepatitis A, B, and E infections, respectively. Selective hepatitis A vaccination (patients younger than 5 years of age) and universal hepatitis B vaccination are required to protect children with CLD. Sanitation improvement and HEV vaccine trial are needed for prevention against HEV.
NASA Astrophysics Data System (ADS)
Haubner, Konstanze; Box, Jason E.; Schlegel, Nicole J.; Larour, Eric Y.; Morlighem, Mathieu; Solgaard, Anne M.; Kjeldsen, Kristian K.; Larsen, Signe H.; Rignot, Eric; Dupont, Todd K.; Kjær, Kurt H.
2018-04-01
Tidewater glacier velocity and mass balance are known to be highly responsive to terminus position change. Yet it remains challenging for ice flow models to reproduce observed ice margin changes. Here, using the Ice Sheet System Model (ISSM; Larour et al. 2012), we simulate the ice velocity and thickness changes of Upernavik Isstrøm (north-western Greenland) by prescribing a collection of 27 observed terminus positions spanning 164 years (1849-2012). The simulation shows increased ice velocity during the 1930s, the late 1970s and between 1995 and 2012 when terminus retreat was observed along with negative surface mass balance anomalies. Three distinct mass balance states are evident in the reconstruction: (1849-1932) with near zero mass balance, (1932-1992) with ice mass loss dominated by ice dynamical flow, and (1998-2012), when increased retreat and negative surface mass balance anomalies led to mass loss that was twice that of any earlier period. Over the multi-decadal simulation, mass loss was dominated by thinning and acceleration responsible for 70 % of the total mass loss induced by prescribed change in terminus position. The remaining 30 % of the total ice mass loss resulted directly from prescribed terminus retreat and decreasing surface mass balance. Although the method can not explain the cause of glacier retreat, it enables the reconstruction of ice flow and geometry during 1849-2012. Given annual or seasonal observed terminus front positions, this method could be a useful tool for evaluating simulations investigating the effect of calving laws.
Marghalani, Siham; Feller, John Kyle; Mahalingam, Meera; Mirzabeigi, Marjan
2015-06-01
Huntington interacting protein 1 (HIP1), an antiapoptotic protein normally expressed in the brain, is highly expressed in Merkel cell carcinomas (MCCs). Given this, the aim of the current study was to ascertain the value of HIP1 as a histopathologic adjunct in the diagnosis of MCC. In this retrospective study, archival material from 26 cases with a diagnosis of MCC and/or neuroendocrine carcinoma were retrieved from the pathology files of the Skin Pathology Laboratory (Boston University School of Medicine, Boston, MA, USA). Histopathologic sections of all cases were re-reviewed and the diagnosis confirmed. All patient data were de-identified. Immunohistochemical studies were performed using antibodies to HIP1 and cytokeratins (CK) 20 and 7. A semiquantitative scoring system for immunohistochemical expression of HIP1 was utilized by deriving a cumulative score (based on percentage positivity of cells and intensity of expression). Using a cut-off total score of 3 or more as positive, the total number of positive cases was 22 for HIP1, 24 for CK20, and 11 for CK7. Comparing the results of HIP1 and CK20, there were four discordant pairs (three positive for CK20 but negative for HIP1 and one positive for HIP1 but negative for CK20). McNemar's test indicated that there was no statistical significance (P = 0.625), thereby implying a close agreement between the expression of HIP1 and CK20 in these neuroendocrine neoplasms. © 2014 The International Society of Dermatology.
Peltonen, Laura-Maria; Lundgrén-Laine, Heljä; Siirala, Eriikka; Löyttyniemi, Eliisa; Aantaa, Riku; Salanterä, Sanna
2018-03-01
The aims were (1) to evaluate the modified version of the Intensive Care Unit Information Need Questionnaire for the broader hospital setting, and (2) to describe the differences in respondents' managerial activities and information needs according to the position held by the respondent and the type of hospital unit. Information systems do not support managerial decision-making sufficiently and information needed in the day-to-day operations management in hospital units is unknown. An existing questionnaire was modified and evaluated. Shift leaders, that is, the nurses and physicians responsible for the day-to-day operations management in hospital units were reached using purposive sampling (n = 258). The questionnaire ascertained the importance of information. Cronbach's α ranged from .85-.96 for the subscales. Item - total correlations showed good explanatory power. Managerial activities and information needs differed between respondents in different positions, although all shared about one-third of important information needs. The response rate was 26% (n = 67). The validity and reliability of the questionnaire were good. Attention should be paid to the positions of shift leaders when developing information systems. The questionnaire can be used to determine important information when developing information systems to support day-to-day operations management in hospitals. © 2018 John Wiley & Sons Ltd.
Sowah, Robert A; Habteselassie, Mussie Y; Radcliffe, David E; Bauske, Ellen; Risse, Mark
2017-01-01
The presence of multiple sources of fecal pollution at the watershed level presents challenges to efforts aimed at identifying the influence of septic systems. In this study multiple approaches including targeted sampling and monitoring of host-specific Bacteroidales markers were used to identify the impact of septic systems on microbial water quality. Twenty four watersheds with septic density ranging from 8 to 373 septic units/km 2 were monitored for water quality under baseflow conditions over a 3-year period. The levels of the human-associated HF183 marker, as well as total and ruminant Bacteroidales, were quantified using quantitative polymerase chain reaction. Human-associated Bacteroidales yield was significantly higher in high density watersheds compared to low density areas and was negatively correlated (r = -0.64) with the average distance of septic systems to streams in the spring season. The human marker was also positively correlated with the total Bacteroidales marker, suggesting that the human source input was a significant contributor to total fecal pollution in the study area. Multivariable regression analysis indicates that septic systems, along with forest cover, impervious area and specific conductance could explain up to 74% of the variation in human fecal pollution in the spring season. The results suggest septic system impact through contributions to groundwater recharge during baseflow or failing septic system input, especially in areas with >87 septic units/km 2 . This study supports the use of microbial source tracking approaches along with traditional fecal indicator bacteria monitoring and land use characterization in a tiered approach to isolate the influence of septic systems on water quality in mixed-use watersheds. Copyright © 2016 Elsevier Ltd. All rights reserved.
Using wide area differential GPS to improve total system error for precision flight operations
NASA Astrophysics Data System (ADS)
Alter, Keith Warren
Total System Error (TSE) refers to an aircraft's total deviation from the desired flight path. TSE can be divided into Navigational System Error (NSE), the error attributable to the aircraft's navigation system, and Flight Technical Error (FTE), the error attributable to pilot or autopilot control. Improvement in either NSE or FTE reduces TSE and leads to the capability to fly more precise flight trajectories. The Federal Aviation Administration's Wide Area Augmentation System (WAAS) became operational for non-safety critical applications in 2000 and will become operational for safety critical applications in 2002. This navigation service will provide precise 3-D positioning (demonstrated to better than 5 meters horizontal and vertical accuracy) for civil aircraft in the United States. Perhaps more importantly, this navigation system, which provides continuous operation across large regions, enables new flight instrumentation concepts which allow pilots to fly aircraft significantly more precisely, both for straight and curved flight paths. This research investigates the capabilities of some of these new concepts, including the Highway-In-The Sky (HITS) display, which not only improves FTE but also reduces pilot workload when compared to conventional flight instrumentation. Augmentation to the HITS display, including perspective terrain and terrain alerting, improves pilot situational awareness. Flight test results from demonstrations in Juneau, AK, and Lake Tahoe, CA, provide evidence of the overall feasibility of integrated, low-cost flight navigation systems based on these concepts. These systems, requiring no more computational power than current-generation low-end desktop computers, have immediate applicability to general aviation flight from Cessnas to business jets and can support safer and ultimately more economical flight operations. Commercial airlines may also, over time, benefit from these new technologies.
NASA Technical Reports Server (NTRS)
Paciotti, Gabriel; Humphries, Martin; Rottmeier, Fabrice; Blecha, Luc
2014-01-01
In the frame of ESA's Solar Orbiter scientific mission, Almatech has been selected to design, develop and test the Slit Change Mechanism of the SPICE (SPectral Imaging of the Coronal Environment) instrument. In order to guaranty optical cleanliness level while fulfilling stringent positioning accuracies and repeatability requirements for slit positioning in the optical path of the instrument, a linear guiding system based on a double flexible blade arrangement has been selected. The four different slits to be used for the SPICE instrument resulted in a total stroke of 16.5 mm in this linear slit changer arrangement. The combination of long stroke and high precision positioning requirements has been identified as the main design challenge to be validated through breadboard models testing. This paper presents the development of SPICE's Slit Change Mechanism (SCM) and the two-step validation tests successfully performed on breadboard models of its flexible blade support system. The validation test results have demonstrated the full adequacy of the flexible blade guiding system implemented in SPICE's Slit Change Mechanism in a stand-alone configuration. Further breadboard test results, studying the influence of the compliant connection to the SCM linear actuator on an enhanced flexible guiding system design have shown significant enhancements in the positioning accuracy and repeatability of the selected flexible guiding system. Preliminary evaluation of the linear actuator design, including a detailed tolerance analyses, has shown the suitability of this satellite roller screw based mechanism for the actuation of the tested flexible guiding system and compliant connection. The presented development and preliminary testing of the high-precision long-stroke Slit Change Mechanism for the SPICE Instrument are considered fully successful such that future tests considering the full Slit Change Mechanism can be performed, with the gained confidence, directly on a Qualification Model. The selected linear Slit Change Mechanism design concept, consisting of a flexible guiding system driven by a hermetically sealed linear drive mechanism, is considered validated for the specific application of the SPICE instrument, with great potential for other special applications where contamination and high precision positioning are dominant design drivers.
NASA Astrophysics Data System (ADS)
Ogunsua, B. O.; Laoye, J. A.
2018-05-01
In this paper, the Tsallis non-extensive q-statistics in ionospheric dynamics was investigated using the total electron content (TEC) obtained from two Global Positioning System (GPS) receiver stations. This investigation was carried out considering the geomagnetically quiet and storm periods. The micro density variation of the ionospheric total electron content was extracted from the TEC data by method of detrending. The detrended total electron content, which represent the variation in the internal dynamics of the system was further analyzed using for non-extensive statistical mechanics using the q-Gaussian methods. Our results reveals that for all the analyzed data sets the Tsallis Gaussian probability distribution (q-Gaussian) with value q > 1 were obtained. It was observed that there is no distinct difference in pattern between the values of qquiet and qstorm. However the values of q varies with geophysical conditions and possibly with local dynamics for the two stations. Also observed are the asymmetric pattern of the q-Gaussian and a highly significant level of correlation for the q-index values obtained for the storm periods compared to the quiet periods between the two GPS receiver stations where the TEC was measured. The factors responsible for this variation can be mostly attributed to the varying mechanisms resulting in the self-reorganization of the system dynamics during the storm periods. The result shows the existence of long range correlation for both quiet and storm periods for the two stations.
NASA Astrophysics Data System (ADS)
Tonkin, T. N.; Midgley, N. G.; Graham, D. J.; Labadz, J. C.
2014-12-01
Novel topographic survey methods that integrate both structure-from-motion (SfM) photogrammetry and small unmanned aircraft systems (sUAS) are a rapidly evolving investigative technique. Due to the diverse range of survey configurations available and the infancy of these new methods, further research is required. Here, the accuracy, precision and potential applications of this approach are investigated. A total of 543 images of the Cwm Idwal moraine-mound complex were captured from a light (< 5 kg) semi-autonomous multi-rotor unmanned aircraft system using a consumer-grade 18 MP compact digital camera. The images were used to produce a DSM (digital surface model) of the moraines. The DSM is in good agreement with 7761 total station survey points providing a total vertical RMSE value of 0.517 m and vertical RMSE values as low as 0.200 m for less densely vegetated areas of the DSM. High-precision topographic data can be acquired rapidly using this technique with the resulting DSMs and orthorectified aerial imagery at sub-decimetre resolutions. Positional errors on the total station dataset, vegetation and steep terrain are identified as the causes of vertical disagreement. Whilst this aerial survey approach is advocated for use in a range of geomorphological settings, care must be taken to ensure that adequate ground control is applied to give a high degree of accuracy.
Impaired Thiol-Disulfide Balance in Acute Brucellosis.
Kolgelier, Servet; Ergin, Merve; Demir, Lutfi Saltuk; Inkaya, Ahmet Cagkan; Aktug Demir, Nazlim; Alisik, Murat; Erel, Ozcan
2017-05-24
The objective of this study was to examine a novel profile: thiol-disulfide homeostasis in acute brucellosis. The study included 90 patients with acute brucellosis, and 27 healthy controls. Thiol-disulfide profile tests were analyzed by a recently developed method, and ceruloplasmin levels were determined. Native thiol levels were 256.72 ± 48.20 μmol/L in the acute brucellosis group and 461.13 ± 45.37 μmol/L in the healthy group, and total thiol levels were 298.58 ± 51.78 μmol/L in the acute brucellosis group and 504.83 ± 51.05 μmol/L in the healthy group (p < 0.001, for both). The disulfide/native thiol ratios and disulfide/total thiol ratios were significantly higher, and native thiol/total thiol ratios were significantly lower in patients with acute brucellosis than in the healthy controls (p < 0.001, for all ratios). There were either positive or negative relationships between ceruloplasmin levels and thiol-disulfide parameters. The thiol-disulfide homeostasis was impaired in acute brucellosis. The strong associations between thiol-disulfide parameters and a positive acute-phase reactant reflected the disruption of the balance between the antioxidant and oxidant systems. Since thiol groups act as anti-inflammatory mediators, the alteration in the thiol-disulfide homeostasis may be involved in brucellosis.
Modeling the total dust production of Enceladus from stochastic charge equilibrium and simulations
NASA Astrophysics Data System (ADS)
Meier, Patrick; Motschmann, Uwe; Schmidt, Jürgen; Spahn, Frank; Hill, Thomas W.; Dong, Yaxue; Jones, Geraint H.; Kriegel, Hendrik
2015-12-01
Negatively and positively charged nano-sized ice grains were detected in the Enceladus plume by the Cassini Plasma Spectrometer (CAPS). However, no data for uncharged grains, and thus for the total amount of dust, are available. In this paper we estimate this population of uncharged grains based on a model of stochastic charging in thermodynamic equilibrium and on the assumption of quasi-neutrality in the plasma-dust system. This estimation is improved upon by combining simulations of the dust component of the plume and simulations for the plasma environment into one self-consistent model. Calibration of this model with CAPS data provides a total dust production rate of about 12 kg s-1, including larger dust grains up to a few microns in size. We find that the fraction of charged grains dominates over that of the uncharged grains. Moreover, our model reproduces densities of both negatively and positively charged nanograins measured by Cassini CAPS. In Enceladus' plume ion densities up to ~104cm-3 are required by the self-consistent model, resulting in an electron depletion of about 50% in the plasma, because electrons are attached to the negatively charged nanograins. These ion densities correspond to effective ionization rates of about 10-7s-1, which are about two orders of magnitude higher than expected.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voigts-Rhetz, P von; Zink, K; University Hospital Giessen-Marburg, Marburg
2016-06-15
Purpose: National and international dosimetry protocols assume a position accuracy for ionization chambers of less than 0.2mm. To follow this precept the manufacturer PTW-Freiburg introduced a positioning assistance system (TRUFIX) for their particular ion chambers. Aim of this study is an experimental investigation of the positioning uncertainties for ROOS-type ionization chambers. Methods: For all measurements a linear accelerator Elekta Synergie was used. The experiments were performed in a water-phantom. To collimate the electron beam a 10×10cm{sup 2} applicator was installed. All measured depth dose curves were normalized to their maximum. In all cases the TRUFIX system was applied for chambermore » positioning. For the first measurement series, to determine the positioning reproducibility of a ROOS chamber, one person placed the chamber three times in a 6 MeV electron beam. The mean value of this three measurements was the reference for further six random persons who repeated this procedure. The results were compared for different depths (R{sub 50}, z{sub ref} and R{sub p}). To investigate the impact of different individual chambers of the same type 10 different ROOS chambers were placed by the same person in a 6, 12 and 18MeV electron beam and the measured reference depths z{sub ref} were compared. Results: The absolute positioning reproducibility is less than 0.1mm for the same person. The positioning uncertainties are increasing up to +/−0.3mm if different persons perform the chamber’s positioning within the water phantom. The comparison of the 10 different ROOS chambers resulted in reference depths z{sub ref} with deviations in the range of +/−0.45mm for all energies. Conclusion: The position accuracy of 0.2mm can be fulfilled with the TRUFIX system. The comparison of the 10 different ROOS ionization chambers showed noticeable deviations in the determined reference depth. The impact of a positioning uncertainty of about 0.3–0.4mm on the total perturbation correction will be considered.« less
Zhao, H; Green, H; Lackenby, A; Donati, M; Ellis, J; Thompson, C; Bermingham, A; Field, J; Sebastianpillai, P; Zambon, M; Watson, Jm; Pebody, R
2014-01-23
During the 2009 influenza A(H1N1) pandemic, a new laboratory-based virological sentinel surveillance system, the Respiratory DataMart System (RDMS), was established in a network of 14 Health Protection Agency (now Public Health England (PHE)) and National Health Service (NHS) laboratories in England. Laboratory results (both positive and negative) were systematically collected from all routinely tested clinical respiratory samples for a range of respiratory viruses including influenza, respiratory syncytial virus (RSV), rhinovirus, parainfluenza virus, adenovirus and human metapneumovirus (hMPV). The RDMS also monitored the occurrence of antiviral resistance of influenza viruses. Data from the RDMS for the 2009–2012 period showed that the 2009 pandemic influenza virus caused three waves of activity with different intensities during the pandemic and post pandemic periods. Peaks in influenza A(H1N1)pdm09 positivity (defined as number of positive samples per total number of samples tested) were seen in summer and autumn in 2009, with slightly higher peak positivity observed in the first post-pandemic season in 2010/2011. The influenza A(H1N1)pdm09 virus strain almost completely disappeared in the second postpandemic season in 2011/2012. The RDMS findings are consistent with other existing community-based virological and clinical surveillance systems. With a large sample size, this new system provides a robust supplementary mechanism, through the collection of routinely available laboratory data at minimum extra cost, to monitor influenza as well as other respiratory virus activity. A near real-time, daily reporting mechanism in the RDMS was established during the London 2012 Olympic and Paralympic Games. Furthermore, this system can be quickly adapted and used to monitor future influenza pandemics and other major outbreaks of respiratory infectious disease, including novel pathogens.
Numerical analysis of urine flow through the side holes of a double J stent in a ureteral stenosis.
Kim, Hyoung-Ho; Choi, Young Ho; Lee, Seung Bae; Baba, Yasutaka; Kim, Kyung-Wuk; Suh, Sang-Ho
2017-07-20
Ureteral stenosis presents with a narrowing in the ureter, due to an intrinsic or extrinsic ureteral disease, such as ureter cancer or retroperitoneal fibrosis. The placement of a double J stent in the upper urinary system is one of the most common treatments of ureteral stenosis, along with the insertion of a percutaneous nephrostomy tube into the renal pelvis. The effect that the side holes in a double J stent have on urine flow has been evaluated in a few studies using straight ureter models. In this study, urine flow through a double J stent's side holes was analyzed in curved ureter models, which were based on human anatomy. In ureteral stenosis, especially in severe ureteral stenosis, a stent with side holes had a positive effect on the luminal and total flow rates, compared with the rates for a stent without side holes. The more side holes a stent has, the greater the luminal and total flow rates. However, the angular positions of the side holes did not affect flow rate. In conclusion, the side holes in a double J stent had a positive effect on ureteral stenosis, and the effect became greater as the ureteral stenosis became more severe.
Gabriel, Doreen; Roschewitz, Indra; Tscharntke, Teja; Thies, Carsten
2006-10-01
Biodiversity studies that guide agricultural subsidy policy have generally compared farming systems at a single spatial scale: the field. However, diversity patterns vary across spatial scales. Here, we examined the effects of farming system (organic vs. conventional) and position in the field (edge vs. center) on plant species richness in wheat fields at three spatial scales. We quantified alpha-, beta-, and gamma-diversity at the microscale in 800 plots, at the mesoscale in 40 fields, and at the macroscale in three regions using the additive partitioning approach, and evaluated the relative contribution of beta-diversity at each spatial scale to total observed species richness. We found that alpha-, beta-, and gamma-diversity were higher in organic than conventional fields and higher at the field edge than in the field center at all spatial scales. In both farming systems, beta-diversity at the meso- and macroscale explained most of the overall species richness (up to 37% and 25%, respectively), indicating considerable differences in community composition among fields and regions due to environmental heterogeneity. The spatial scale at which beta-diversity contributed the most to overall species richness differed between rare and common species. Total richness of rare species (present in < or = 5% of total samples) was mainly explained by differences in community composition at the meso- and macroscale (up to 27% and 48%, respectively), but only in organic fields. Total richness of common species (present in > or = 25% of total samples) was explained by differences in community composition at the micro- and mesoscale (up to 29% and 47%, respectively), i.e., among plots and fields, independent of farming system. Our results show that organic farming made the greatest contribution to total species richness at the meso (among fields) and macro (among regions) scale due to environmental heterogeneity. Hence, agri-environment schemes should exploit this large-scale contribution of beta-diversity by tailoring schemes at regional scales to maximize dissimilarity between conservation areas using geographic information systems rather than focusing entirely at the classical local-field scale, which is the current practice.
Comparison of different in-house test systems to detect parvovirus in faeces of cats.
Neuerer, Felix F; Horlacher, Karin; Truyen, Uwe; Hartmann, Katrin
2008-07-01
In-house tests for the identification of faecal parvovirus antigen are now available. The majority of these are licensed for canine parvovirus only; but anecdotal information suggests that they will detect feline panleukopenia virus (FPV) as well. This prospective study was designed to compare five commercially available test systems. In total, 200 faecal samples from randomly selected healthy cats (148) and cats with diarrhoea (52) were tested and compared with the results of examination by electron microscopy. Ten cats were positive for FPV and all of these had diarrhoea. In-house canine parvovirus tests can be used to detect FPV. All tests were suitable to screen cats for faecal parvovirus excretion (positive predictive values for the Witness Parvo, the Snap Parvo, the SAS Parvo, the Fastest Parvo Strip, and the Speed Parvo were 100.0, 100.0, 57.1, 38.9, and 100%, respectively, negative predictive values for the Witness Parvo, the Snap Parvo, the SAS Parvo, the Fastest Parvo Strip, and the Speed Parvo were 97.4, 97.9, 98.9, 98.4, and 97.4%, respectively). In-house parvovirus tests may be positive up to 2 weeks after vaccination, and therefore, in recently vaccinated cats positive results do not necessarily mean infection.
Dynamic Positioning Capability Analysis for Marine Vessels Based on A DPCap Polar Plot Program
NASA Astrophysics Data System (ADS)
Wang, Lei; Yang, Jian-min; Xu, Sheng-wen
2018-03-01
Dynamic positioning capability (DPCap) analysis is essential in the selection of thrusters, in their configuration, and during preliminary investigation of the positioning ability of a newly designed vessel dynamic positioning system. DPCap analysis can help determine the maximum environmental forces, in which the DP system can counteract in given headings. The accuracy of the DPCap analysis is determined by the precise estimation of the environmental forces as well as the effectiveness of the thrust allocation logic. This paper is dedicated to developing an effective and efficient software program for the DPCap analysis for marine vessels. Estimation of the environmental forces can be obtained by model tests, hydrodynamic computation and empirical formulas. A quadratic programming method is adopted to allocate the total thrust on every thruster of the vessel. A detailed description of the thrust allocation logic of the software program is given. The effectiveness of the new program DPCap Polar Plot (DPCPP) was validated by a DPCap analysis for a supply vessel. The present study indicates that the developed program can be used in the DPCap analysis for marine vessels. Moreover, DPCap analysis considering the thruster failure mode might give guidance to the designers of vessels whose thrusters need to be safer.
Kelty, Clive J; Kennedy, Catherine W; Falk, Gregory L
2010-09-01
The role of the number of metastatic nodes in esophageal cancer surgery is of interest. We assess predictors of survival after oesophagectomy for esophageal and gastroesophageal junction malignancy. Prospective data of consecutive patients undergoing oesophagectomy and systematic lymphadenectomy between 1991 and 2007. Of 224 patients, 148 patients (66%) had adenocarcinoma, 70 (31%) squamous cell carcinoma, and 6 (2.6%) were other tumor types. Five-year survival was 43% with hospital mortality of 3.5%. Locoregional recurrence occurred in 14%. The total number of affected nodes significantly reduced survival (four or more metastatic nodes). Further analysis of the ratio of nodes affected to the total number resected showed a significant decrease in survival as the percentage of positive nodes increased (p < 0.001). Patients undergoing surgery for esophageal cancer should be staged according to a minimum total number of metastatic lymph nodes and ratios because this more accurately predicts survival than current staging systems.
Physician Update: Total Health
Tuso, Phillip
2014-01-01
As an integrated prepaid health care system, Kaiser Permanente (KP) is in a unique position to demonstrate that affordability in health care can be achieved by disease prevention. During the past decade, KP has significantly improved the quality care outcomes of its members with preventable diseases. However, because of an increase in the incidence of preventable disease, and the potential long-term and short-term costs associated with the treatment of preventable disease, KP has developed a new strategy called Total Health to meet the current and future needs of its patients. Total Health means healthy people in healthy communities. KP’s strategic vision is to be a leader in Total Health by making lives better. KP hopes to make lives better by 1) measuring vital signs of health, 2) promoting healthy behaviors, 3) monitoring disease incidence, 4) spreading leading practices, and 5) creating healthy environments with our community partners. Best practices, spread to the communities we serve, will make health care more affordable, prevent preventable diseases, and save lives. PMID:24694316
Ash level meter for a fixed-bed coal gasifier
Fasching, George E.
1984-01-01
An ash level meter for a fixed-bed coal gasifier is provided which utilizes the known ash level temperature profile to monitor the ash bed level. A bed stirrer which travels up and down through the extent of the bed ash level is modified by installing thermocouples to measure the bed temperature as the stirrer travels through the stirring cycle. The temperature measurement signals are transmitted to an electronic signal process system by an FM/FM telemetry system. The processing system uses the temperature signals together with an analog stirrer position signal, taken from a position transducer disposed to measure the stirrer position to compute the vertical location of the ash zone upper boundary. The circuit determines the fraction of each total stirrer cycle time the stirrer-derived bed temperature is below a selected set point, multiplies this fraction by the average stirrer signal level, multiplies this result by an appropriate constant and adds another constant such that a 1 to 5 volt signal from the processor corresponds to a 0 to 30 inch span of the ash upper boundary level. Three individual counters in the processor store clock counts that are representative of: (1) the time the stirrer temperature is below the set point (500.degree. F.), (2) the time duration of the corresponding stirrer travel cycle, and (3) the corresponding average stirrer vertical position. The inputs to all three counters are disconnected during any period that the stirrer is stopped, eliminating corruption of the measurement by stirrer stoppage.
Validation of the Spatial Accuracy of the ExacTracRTM Adaptive Gating System
NASA Astrophysics Data System (ADS)
Twork, Gregory
Stereotactic body radiation therapy (SBRT) is a method of treatment that is used in extracranial locations, including the abdominal and thoracic cavities, as well as spinal and paraspinal locations. At the McGill University Health Centre, liver SBRT treatments include gating, which places the treatment beam on a duty cycle controlled by tracking of fiducial markers moving with the patient's breathing cycle. Respiratory gated treatments aim to spare normal tissue, while delivering a dose properly to a moving target. The ExacTracRTM system (BrainLAB AG Germany) is an image-guided radiotherapy system consisting of a combination of infra-red (IR) cameras and dual kilovoltage (kV) X-ray tubes. The IR system is used to track patient positioning and respiratory motion, while the kV X-rays are used to determine a positional shift based on internal anatomy or fiducial markers. In order to validate the system's ability to treat under gating conditions, each step of the SBRT process was evaluated quantitatively. Initially the system was tested under ideal static conditions, followed by a study including gated parameters. The uncertainties of the isocenters, positioning algorithm, planning computed tomography (CT) and four dimensional CT (4DCT) scans, gating window size and tumor motion were evaluated for their contributions to the total uncertainty in treatment. The mechanical isocenter and 4DCT were found to be the largest sources of uncertainty. However, for tumors with large internal amplitudes (>2.25 cm) that are treated with large gating windows (>30%) the gating parameters can contribute more than 1.1 +/- 1.8 mm.
Xu, Defu; Li, Yingxue; Fan, Xiaolong; Guan, Yidong; Fang, Hua; Zhao, Xiaoli
2013-01-01
Four constructed wetland systems were studied to investigate the effects of adding Eisenia fetida on the purifying capacity of constructed wetlands. Addition of E. fetida increased the photosynthetic rate (Pn), transpiration rate (Tr) and chlorophyll meter value of leaves of Iris pseudacorus L. in the constructed wetlands by 16, 35 and 7%, respectively. Compared with the substrate only system, evapotranspiration losses were increased by 8, 48 and 56% for the wetland systems with substrate and E. fetida, with substrate and I. pseudacorus, and with substrate, I. pseudacorus and E. fetida, respectively. Addition of E. fetida to the substrate only and substrate and plant wetland systems decreased the substrate bulk density by 3 and 6%, respectively. The addition of E. fetida to the system with substrate and plants increased the removal efficiency of chemical oxygen demand (CODMn), total nitrogen (TN) and total phosphorus by 5, 7 and 22%, respectively. Evapotranspiration losses were significantly positively correlated with the removal efficiency of CODMn (P < 0.01). The significantly negative correlation between the removal efficiency TN and bulk density was found (P < 0.05). Therefore, E. fetida could stimulate I. pseudacorus growth and improve the substrate bulk density in the constructed wetland, resulting in enhanced purifying capacity.
Du, Dongxing; Jiang, Song; Wang, Ze; Hu, Yingying; He, Zhaoming
2014-01-01
Mitral valve (MV) edge-to-edge repair (ETER) is a surgical procedure for the correction of mitral valve regurgitation by suturing the free edge of the leaflets. The leaflets are often sutured at three different positions: central, lateral and commissural portions. To study the effects of position of suture on left ventricular (LV) fluid mechanics under mitral valve ETER, a parametric model of MV-LV system during diastole was developed. The distribution and development of vortex and atrio-ventricular pressure under different suture position were investigated. Results show that the MV sutured at central and lateral in ETER creates two vortex rings around two jets, compared with single vortex ring around one jet of the MV sutured at commissure. Smaller total orifices lead to a higher pressure difference across the atrio-ventricular leaflets in diastole. The central suture generates smaller wall shear stresses than the lateral suture, while the commissural suture generated the minimum wall shear stresses in ETER.
Park, Youngmok; Kim, Hyemin; Kim, Eui-Hyun; Suh, Chang-Ok; Lee, Soohyeon
2016-01-01
Brain metastasis affects one third of patients with HER2-positive breast cancer after treatment with trastuzumab. Surgical resection and radiation therapy are often unsuccessful at accomplishing complete control of metastasis. Lapatinib is presumed to cross the blood-brain barrier, and exhibits clinical activities for treatment of HER2-positive breast cancer. A 43-year-old woman was treated for early breast carcinoma with total mastectomy, axillary lymph-node dissection, and adjuvant chemotherapy with cyclophosphamide plus doxorubicin. After the end of adjuvant trastuzumab therapy, she was diagnosed with panhypopituitarism due to pituitary metastasis. Surgical removal and whole brain radiation therapy were performed, but a portion of viable tumor remained. Only taking lapatinib, the size of the metastatic lesion began to shrink. Trastuzumab may have controlled the micro-metastasis of breast cancer, but it was unable to control its progression to the central nervous system. Lapatinib is a possible option for HER2-positive metastatic breast cancer patients with brain metastasis.
Error modeling for differential GPS. M.S. Thesis - MIT, 12 May 1995
NASA Technical Reports Server (NTRS)
Blerman, Gregory S.
1995-01-01
Differential Global Positioning System (DGPS) positioning is used to accurately locate a GPS receiver based upon the well-known position of a reference site. In utilizing this technique, several error sources contribute to position inaccuracy. This thesis investigates the error in DGPS operation and attempts to develop a statistical model for the behavior of this error. The model for DGPS error is developed using GPS data collected by Draper Laboratory. The Marquardt method for nonlinear curve-fitting is used to find the parameters of a first order Markov process that models the average errors from the collected data. The results show that a first order Markov process can be used to model the DGPS error as a function of baseline distance and time delay. The model's time correlation constant is 3847.1 seconds (1.07 hours) for the mean square error. The distance correlation constant is 122.8 kilometers. The total process variance for the DGPS model is 3.73 sq meters.
Student's Second-Language Grade May Depend on Classroom Listening Position.
Hurtig, Anders; Sörqvist, Patrik; Ljung, Robert; Hygge, Staffan; Rönnberg, Jerker
2016-01-01
The purpose of this experiment was to explore whether listening positions (close or distant location from the sound source) in the classroom, and classroom reverberation, influence students' score on a test for second-language (L2) listening comprehension (i.e., comprehension of English in Swedish speaking participants). The listening comprehension test administered was part of a standardized national test of English used in the Swedish school system. A total of 125 high school pupils, 15 years old, participated. Listening position was manipulated within subjects, classroom reverberation between subjects. The results showed that L2 listening comprehension decreased as distance from the sound source increased. The effect of reverberation was qualified by the participants' baseline L2 proficiency. A shorter reverberation was beneficial to participants with high L2 proficiency, while the opposite pattern was found among the participants with low L2 proficiency. The results indicate that listening comprehension scores-and hence students' grade in English-may depend on students' classroom listening position.
Student’s Second-Language Grade May Depend on Classroom Listening Position
Sörqvist, Patrik; Ljung, Robert; Hygge, Staffan; Rönnberg, Jerker
2016-01-01
The purpose of this experiment was to explore whether listening positions (close or distant location from the sound source) in the classroom, and classroom reverberation, influence students’ score on a test for second-language (L2) listening comprehension (i.e., comprehension of English in Swedish speaking participants). The listening comprehension test administered was part of a standardized national test of English used in the Swedish school system. A total of 125 high school pupils, 15 years old, participated. Listening position was manipulated within subjects, classroom reverberation between subjects. The results showed that L2 listening comprehension decreased as distance from the sound source increased. The effect of reverberation was qualified by the participants’ baseline L2 proficiency. A shorter reverberation was beneficial to participants with high L2 proficiency, while the opposite pattern was found among the participants with low L2 proficiency. The results indicate that listening comprehension scores—and hence students’ grade in English—may depend on students’ classroom listening position. PMID:27304980
Design and Integration of a Rotor Alone Nacelle for Acoustic Fan Testing
NASA Technical Reports Server (NTRS)
Shook, Tony D.; Hughes, Christoper E.; Thompson, William K.; Tavernelli, Paul F.; Cunningham, Cameron C.; Shah, Ashwin
2001-01-01
A brief summary of the design, integration and testing of a rotor alone nacelle (RAN) in NASA Glenn's 9'x 15' Low Speed Wind Tunnel (LSWT) is presented. The purpose of the RAN system was to provide an "acoustically clean" flow path within the nacelle to isolate that portion of the total engine system acoustic signature attributed to fan noise. The RAN design accomplished this by removing the stators that provided internal support to the nacelle. In its place, two external struts mounted to a two-axis positioning table located behind the tunnel wall provided the support. Nacelle-mounted lasers and a closed-loop control system provided the input to the table to maintain nacelle to fan concentricity as thermal and thrust loads displaced the strut-mounted fan. This unique design required extensive analysis and verification testing to ensure the safety of the fan model, propulsion simulator drive rig, and facility, along with experimental consistency of acoustic data obtained while using the RAN system. Initial testing was used to optimize the positioning system and resulted in concentricity errors of +/- 0.0031 in. in the horizontal direction and +0.0035/-0.0013 in, in the vertical direction. As a result of successful testing, the RAN system will be transitioned into other acoustic research programs at NASA Glenn Research Center.
Varadarajan, Kartik M; Harry, Rubash E; Johnson, Todd; Li, Guoan
2009-10-01
In vitro systems provide a powerful means to evaluate the efficacy of total knee arthroplasty (TKA) in restoring normal knee kinematics. The Oxford knee rig (OKR) and the robotic knee testing system (RKTS) represent two systems that have been extensively used to study TKA biomechanics. Nonetheless, a frequently asked question is whether in vitro simulations can capture the in vivo behavior of the knee. Here, we compared the flexion-extension kinematics of intact knees and knees after TKA tested on the OKR and RKTS, to results of representative in vivo studies. The goal was to determine if the in vitro systems could capture the key kinematic features of knees in healthy subjects and TKA patients. Results showed that the RKTS and the OKR can replicate the femoral rollback and 'screw home' tibial rotation between 0 degrees and 30 degrees flexion seen in healthy subjects, and the reduced femoral rollback and absence of 'screw home' motion in TKA patients. The RKTS also replicated the overall internally rotated position of the tibia beyond 30 degrees flexion. However, ability of the OKR to replicate the internally rotated position of the knee beyond 30 degrees flexion was inconsistent. These data could aid in validation of new in vitro systems and physiologic interpretations of in vitro results.
Koopman, K E; Roefs, A; Elbers, D C E; Fliers, E; Booij, J; Serlie, M J; la Fleur, S E
2016-06-01
In rodents, the striatal dopamine (DA) system and the (hypo)thalamic serotonin (5-HT) system are involved in the regulation of feeding behavior. In lean humans, little is known about the relationship between these brain neurotransmitter systems and feeding. We studied the relationship between striatal DA transporters (DAT) and diencephalic 5-HT transporters (SERT), behavioral tasks and questionnaires, and food intake. We measured striatal DAT and diencephalic SERT binding with [123I]FP-CIT SPECT in 36 lean male subjects. Visual attention bias for food (detection speed and distraction time) and degree of impulsivity were measured using response-latency-based computer tasks. Craving and emotional eating were assessed with questionnaires and ratings of hunger by means of VAS scores. Food intake was assessed through a self-reported online diet journal. Striatal DAT and diencephalic SERT binding negatively correlated with food detection speed (p = 0.008, r = -0.50 and p = 0.002, r = -0.57, respectively), but not with food distraction time, ratings of hunger, craving or impulsivity. Striatal DAT and diencephalic SERT binding did not correlate with free choice food intake, whereas food detection speed positively correlated with total caloric intake (p = 0.001, r = 0.60), protein intake (p = 0.01, r = 0.44), carbohydrate intake (p = 0.03, r = 0.39) and fat intake (p = 0.06, r = 0.35). These results indicate a role for the central 5-HT and DA system in the regulation of visual attention bias for food, which contributes to the motivation to eat, in non-obese, healthy humans. In addition, this study confirms that food detection speed, measured with the latency-based computer task, positively correlates with total food and macronutrient intake.
Parvaneh Tafreshi, Azita; Talebi, Farideh; Ghorbani, Samira; Bernard, Claude; Noorbakhsh, Farshid
2017-10-01
There is growing evidence that the impaired IGF-I system contributes to neurodegeneration. In this study, we examined the spinal cords of the EAE, the animal model of multiple sclerosis, to see if the expression of the IGF-I system is altered. To induce EAE, C57/BL6 mice were immunized with the Hooke lab MOG kit, sacrificed at the peak of the disease and their spinal cords were examined for the immunoreactivities (ir) of the IGF-I, IGF binding protein-1 (IGFBP-1) and glycogen synthase kinase 3β (GSK3β), as one major downstream molecule in the IGF-I signaling. Although neurons in the non EAE spinal cords did not show the IGF-I immunoreactivity, they were numerously positive for the IGFBP-1. In the inflamed EAE spinal cord however, the patterns of expressions were reversed, that is, a significant increased number of IGF-I expressing neurons versus a reduced number of IGFBP-1 positive neurons. Moreover, while nearly all IGF-I-ir neurons expressed GSK3β, some expressed it more intensely. Considering our previous finding where we showed a significant reduced number of the inactive (phosphorylated) but not that of the total GSK3β expressing neurons in the EAE spinal cord, it is conceivable that the intense total GSK3β expression in the IGF-I-ir neurons belongs to the active form of GSK3β known to exert neuroinflammatory effects. We therefore suggest that the altered expression of the IGF-I system including GSK3β in spinal cord neurons might involve in pathophysiological events during the EAE. © 2017 Wiley Periodicals, Inc.
Walker, Luke; Chinnaiyan, Prakash; Forster, Kenneth
2008-01-01
We conducted a comprehensive evaluation of the clinical accuracy of an image‐guided frameless intracranial radiosurgery system. All links in the process chain were tested. Using healthy volunteers, we evaluated a novel method to prospectively quantify the range of target motion for optimal determination of the planning target volume (PTV) margin. The overall system isocentric accuracy was tested using a rigid anthropomorphic phantom containing a hidden target. Intrafraction motion was simulated in 5 healthy volunteers. Reinforced head‐and‐shoulders thermoplastic masks were used for immobilization. The subjects were placed in a treatment position for 15 minutes (the maximum expected time between repeated isocenter localizations) and the six‐degrees‐of‐freedom target displacements were recorded with high frequency by tracking infrared markers. The markers were placed on a customized piece of thermoplastic secured to the head independently of the immobilization mask. Additional data were collected with the subjects holding their breath, talking, and deliberately moving. As compared with fiducial matching, the automatic registration algorithm did not introduce clinically significant errors (<0.3 mm difference). The hidden target test confirmed overall system isocentric accuracy of ≤1 mm (total three‐dimensional displacement). The subjects exhibited various patterns and ranges of head motion during the mock treatment. The total displacement vector encompassing 95% of the positional points varied from 0.4 mm to 2.9 mm. Pre‐planning motion simulation with optical tracking was tested on volunteers and appears promising for determination of patient‐specific PTV margins. Further patient study is necessary and is planned. In the meantime, system accuracy is sufficient for confident clinical use with 3 mm PTV margins. PACS number: 87.53.Ly
Yağmur, Gülhan; Albayrak, Nurhan; Daş, Taner; Yıldırım, Muzaffer; Ozgün, Ayşe; Büyük, Yalçın
2014-10-01
Tuberculosis (TB) is one of those infections with high morbidity and mortality in all around the world. Hundreds of people died from this disease without diagnosed or due to resistant strains in Turkey. Therefore, it is important to identify postmortem cases who have died from tuberculosis. Molecular methods have been widely used as well as conventional methods in the diagnosis of tuberculosis. The aim of this study was to compare the two different real-time polymerase chain reaction (Rt-PCR) system in the postmortem diagnosis of Mycobacterium tuberculosis infections in paraffin-embedded tissues. A total of 40 paraffin-embedded tissue samples [lung (n= 35), brain (n= 2), heart (n= 2), lymph node (n= 1)] in which histopathologic findings consistent with TB (necrotizing granulomatous inflammation, gelatinous caseous pneumonia, necrotic fibrous nodul) obtained from 37 autopsy cases (31 male, 6 female; age range: 25-85 yrs) were included in the study. Paraffin-embedded tissues were deparafinized with xylene and ethyl alcohol and then DNA isolation was done with QIAsymphony DSP Virus/Pathogen Midi kit in the QIAsymphony device. DNA amplification process was performed by Rt-PCR using the kit Artus® M. tuberculosis RG-PCR in the Rotor-Gene® Q device (Qiagen, Germany). Likewise, after deparafinization process, samples placed in the cartridge and isolation and Rt-PCR was performed by Xpert® MTB/RIF (Cepheid, USA) system, simultaneosly. Seventeen and 20 out of the 40 paraffin-embedded tissues yielded positive results with Qiagen and Xpert system, respectively. M.tuberculosis DNA was found positive in 13 (32.5%) and negative in 16 (40%) of the samples by both of the systems, exhibiting 72.5% (29/40) of concordance. On the other hand, seven (17.5%) samples that were positive with Xpert system yielded negative result with the Qiagen, while four (10%) samples that were positive with Qiagen yielded negative result with the Xpert system. Of the 20 positive cases detected with Xpert MTB/RIF system, 15 were found rifampicin-susceptible, and three were rifampicin-resistant. In two samples in which M. tuberculosis DNA was low positive, rifampicin resistance could not be detected. The identification of M.tuberculosis infections in postmortem cases will contribute epidemiological data in Turkey. In these cases, effective sampling and diagnosing of M.tuberculosis infections by acid-fast stain and culture methods are crucial. However, in cases without microbiological sampling the detection of M.tuberculosis DNA in paraffin-embedded tissues with PCR, although there are differences between PCR systems has diagnostic value. In conclusion, our data indicated that Xpert MTB/RIF system is more favourable to detect M.tuberculosis DNA in paraffin-embedded tissues, with the advantages of determination of rifampicin resistance, and detection of more positive results within a shorter time.
Lam, C P; Tsai, W C
1989-08-01
A total of 813 routine isolates of aerobic and facultatively anaerobic bacteria were employed to determine the efficacy of different branded (Oxoid, Difco, BBL) antimicrobial disks, using disk antimicrobial susceptibility tests, for a total of 22 kinds of antimicrobial disks and 10,740 antibiotic-organism comparisons. Major positive and major negative discrepancies in results were defined as a change from "susceptible" to "both resistant", and a change from "resistant" to "both susceptible" according to the National Committee for Clinical Laboratory Standards' interpretive standards for zone diameters. Minor positive and minor negative discrepancies were defined as a change from "susceptible" to "both intermediate", or "intermediate" to "both resistant"; and a change from "resistant" to "both intermediate", or "intermediate" to "both susceptible". The overall agreements of Oxoid, Difco, and BBL systems were 98%, 98.7%, and 98.4% respectively, and their differences are not statistically significant. Different kinds of antimicrobial disks' representative patterns of these three brands are further analyzed: (A) In the Oxoid series, there were 220 discrepancies. Minor negative discrepancy is predominant, most frequently related to carbenicillin (25), gentamicin (13) and cephalothin (10). Besides minor negative discrepancy, carbenicillin also had six minor positive discrepancies. Tetracyclin had ten minor positive discrepancies. (B) In the Difco series, there were 137 discrepancies. The majority of them are minor positive discrepancies. Moxalactam (11) and cefotaxime (10) are the most common antibiotics involved. (C) In the BBL series, there were 170 discrepancies. Minor positive discrepancy was the predominant one, which mostly related to carbenicillin (24), amikacin (13), and ceftizoxime (12). In addition, tetracyclin had 24 times minor negative discrepancies. Laboratory workers must pay attention to these different patterns of representation. In order to evaluate the quality of 11 pairs of the give-away and the purchased BBL disks, we also compared the results for these 813 routine isolates (a total of 5,482 antibiotic-organism comparisons). The giveaway disks demonstrated 99.1% overall agreement with the purchased disks. There were 48 minor discrepancies [26 (0.47%) minor positive discrepancies and 22 (0.4%) minor negative discrepancies]. These results allow this study to emphasize the followings in order to raise the awareness of the laboratory workers: (i) alteration of disk efficacy during transportation and storage; (ii) major considerations in choosing different brands' antimicrobial disks, and (iii) the important roles played by salespersons and pharmaceutical companies in achieving sound results.
Buczinski, S; Faure, C; Jolivet, S; Abdallah, A
2016-07-01
To determine inter-observer agreement for a clinical scoring system for the detection of bovine respiratory disease complex in calves, and the impact of classification of calves as sick or healthy based on different cut-off values. Two third-year veterinary students (Observer 1 and 2) and one post-graduate student (Observer 3) received 4 hours of training on scoring dairy calves for signs of respiratory disease, including rectal temperature, cough, eye and nasal discharge, and ear position. Observers 1 and 2 scored 40 pre-weaning dairy calves 24 hours apart (80 observations) over three visits to a calf-rearing facility, and Observers 1, 2 and 3 scored 20 calves on one visit. Inter-observer agreement was assessed using percentage of agreement (PA) and Kappa statistics for individual clinical signs, comparing Observers 1 and 2. Agreement between the three observers for total clinical score was assessed using cut-off values of ≥4, ≥5 and ≥6 to indicate unhealthy calves. Inter-observer PA for rectal temperature was 0.68, for cough 0.78, for nasal discharge 0.62, for eye discharge 0.63, and for ear position 0.85. Kappa values for all clinical signs indicated slight to fair agreement (<0.4), except temperature that had moderate agreement (0.6). The Fleiss' Kappa for total score, using cut-offs of ≥4, ≥5 and ≥6 to indicate unhealthy calves, was 0.35, 0.06 and 0.13, respectively, indicating slight to fair agreement. There was important inter-observer discrepancies in scoring clinical signs of respiratory disease, using relatively inexperienced observers. These disagreements may ultimately mean increased false negative or false positive diagnoses and incorrect treatment of cases. Visual assessment of clinical signs associated with bovine respiratory disease needs to be thoroughly validated when disease monitoring is based on the use of a clinical scoring system.
Alegria-Moran, R; Rivera, D; Toledo, V; Moreno-Switt, A I; Hamilton-West, C
2017-11-01
Little is known about Salmonella serovars circulating in backyard poultry and swine populations worldwide. Backyard production systems (BPS) that raise swine and/or poultry are distributed across Chile, but are more heavily concentrated in central Chile, where industrialized systems are in close contact with BPS. This study aims to detect and identify circulating Salmonella serovars in poultry and swine raised in BPS. Bacteriological Salmonella isolation was carried out for 1744 samples collected from 329 BPS in central Chile. Faecal samples were taken from swine, poultry, geese, ducks, turkeys and peacocks, as well as environmental faecal samples. Confirmation of Salmonella spp. was performed using invA-polymerase chain reaction (PCR). Identification of serovars was carried out using a molecular serotyping approach, where serogroups were confirmed by a multiplex PCR of Salmonella serogroup genes for five Salmonella O antigens (i.e., D, B, C1, C2-C3, and E1), along with two PCR amplifications, followed by sequencing of fliC and fljB genes. A total of 25 samples (1·4% of total samples) from 15 BPS (4·6 % of total sampled BPS) were found positive for Salmonella. Positive samples were found in poultry (chickens and ducks), swine and environmental sources. Molecular prediction of serovars on Salmonella isolated showed 52·0% of S. Typhimurium, 16·0% of S. Infantis, 16·0% S. Enteritidis, 8·0% S. Hadar, 4·0% S. Tennessee and 4·0% S. Kentucky. Poor biosecurity measures were found on sampled BPS, where a high percentage of mixed confinement systems (72·8%); and almost half of the sampled BPS with improper management of infected mortalities (e.g. selling the carcasses of infected animals for consumption). Number of birds other than chickens (P = 0·014; OR = 1·04; IC (95%) = 1·01-1·07), mixed productive objective (P = 0·030; OR = 5·35; IC (95%) = 1·24-27·59) and mixed animal replacement origin (P = 0017; OR = 5·19; IC (95%) = 1·35-20·47) were detected as risk factors for BPS positivity to Salmonella spp. This is the first evidence of serovars of Salmonella spp. circulating in BPS from central Chile. Detected serovars have been linked to human and animal clinical outbreaks worldwide and in Chile, highlighting the importance of BPS on the control and dissemination of Salmonella serovars potentially hazardous to public health.
Kol, Emine; İlaslan, Emine; Turkay, Mehtap
2017-08-01
The objective of this study was to identify the satisfaction levels of nurses with positive environment initiatives and positive management strategies. In total, 235 and 259 nurses participated in the study before and after the application of the initiatives and strategies, respectively. Strategies adopted from the magnet model to create positive work environments and management styles were executed according to the forces of magnetism. Data related to satisfaction were collected twice, once before and once after the strategies to create positive working environments were implemented. The rates of working environment satisfaction in the nurses' department were 57.07% in 2011 and 69.01% in 2013. The rate of satisfaction with governance differed significantly between 2011 and 2013, especially in terms of the merit system, equity and equality, information flow between the administration and the employees, and the influence of the nursing managers on institutional decision making. This study showed that 24 months after the implementation of these strategies, nurse satisfaction with their work environment and management style increased significantly. © 2017 John Wiley & Sons Australia, Ltd.
Rufai, Syed Beenish; Singh, Amit; Singh, Jitendra; Kumar, Parveen; Sankar, Manimuthu Mani; Singh, Sarman
2017-08-01
Tuberculous meningitis (TBM) is the most severe form of extra-pulmonary tuberculosis (TB) due to association of diseases with high rates of mortality and morbidity. Diagnosis continues to be a clinical challenge as microbiological confirmation is rare and time consuming resulting in delayed treatment. Xpert MTB/RIF assay is a rapid and simple test, which has been endorsed by World Health Organization as an initial diagnostic test for the diagnosis of TBM. However, evidence still lacks for its performance on cerebrospinal fluid (CSF) for the diagnosis of TBM especially from India. A total of 267 CSF samples from patients with high clinico-radiological suspicion of TBM were included in this study. Ziehl-Neelsen (ZN) staining, BACTEC Mycobacterial Growth Indicator Tube (MGIT-960) culture system, and Xpert MTB/RIF assay (using cartridge version G4) were tested on all samples. Of total 267 samples, all were negative for smear AFB and 52 (19.5%) were culture positive by MGIT-960 culture system. However, out of 52 (19.5%) cultures detected positive by MGIT-960, 5 (9.6%) were detected as resistant to rifampicin. Xpert MTB/RIF assay was positive in 38 (14.2%) samples and negative in 223 (83.5%) samples. Cartridge error was detected in 6 (2.2%) samples, which could not be repeated due to insufficient sample volume. The sensitivity and specificity of Xpert MTB/RIF assay in comparison to MGIT-960 was 55.1% (95%, CI: 40.2-69.3) and 94.8% (95%, CI: 90.9-97.4) respectively. Overall, Xpert MTB/RIF assay detected 38 (14.2%) as positive for MTB of which 4 (10.5%), 31 (81.6%) and 3 (7.9%) were found to be rifampicin resistant, sensitive and indeterminate respectively. Xpert MTB/RIF assay showed lower sensitivity as compared to MGIT 960 culture for the diagnosis of TBM from CSF samples. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
Eradication of Mycoplasma hyopneumoniae from a swine finishing herd without total depopulation.
Heinonen, Mari; Laurila, Tapio; Vidgren, Gabriele; Levonen, Katri
2011-04-01
Using vaccination and medication, Mycoplasma hyopneumoniae (Mhyo) was eradicated from a finishing herd without total depopulation. Altogether 3243 feeder pigs originating from Mhyo-free herds were vaccinated once using an inactivated, adjuvanted vaccine before transporting them to a Mhyo-infected finishing herd. The Mhyo-infected groups of pigs were medicated with antimicrobial agents at the time of the arrival of the first groups of Mhyo-free, vaccinated feeder pigs. The groups were operated with an all-in-all-out method in rooms with separate ventilation and slurry disposal systems. Thereafter the farmer purchased only non-vaccinated feeder pigs originating from Mhyo-free sow herds. Serology gave no positive results for 5.5 years and it was concluded that the eradication programme had been successful in producing a Mhyo-free herd without total depopulation. Copyright © 2010 Elsevier Ltd. All rights reserved.
Total Laparoscopic Hysterectomy Under Regional Anesthesia.
Moawad, Nash S; Santamaria Flores, Estefania; Le-Wendling, Linda; Sumner, Martina T; Enneking, F Kayser
2018-05-07
Laparoscopic hysterectomies comprise a large proportion of all hysterectomies in the United States. Procedures completed under regional anesthesia pose a number of benefits to patients, but laparoscopic hysterectomies traditionally have been performed under general anesthesia. We describe a case of total laparoscopic hysterectomy under epidural anesthesia with the patient fully awake. A 51-year-old woman with abnormal uterine bleeding underwent an uncomplicated total laparoscopic hysterectomy, bilateral salpingectomy, and excision of endometriosis. The procedure was completed under epidural anesthesia without intravenous sedation or systemic narcotics. Pneumoperitoneum with a pressure of 12 mm Hg and Trendelenburg to 15° allowed for adequate visualization. Anesthesia was achieved with midthoracic and low lumbar epidural catheters. Bilevel positive airway pressure was used for augmentation of respiratory function. With a committed patient, adequate planning, and knowledge of the potential intraoperative complications, regional anesthesia is an option for select women undergoing laparoscopic hysterectomy.
Ionospheric responses during equinox and solstice periods over Turkey
NASA Astrophysics Data System (ADS)
Karatay, Secil; Cinar, Ali; Arikan, Feza
2017-11-01
Ionospheric electron density is the determining variable for investigation of the spatial and temporal variations in the ionosphere. Total Electron Content (TEC) is the integral of the electron density along a ray path that indicates the total variability through the ionosphere. Global Positioning System (GPS) recordings can be utilized to estimate the TEC, thus GPS proves itself as a useful tool in monitoring the total variability of electron distribution within the ionosphere. This study focuses on the analysis of the variations of ionosphere over Turkey that can be grouped into anomalies during equinox and solstice periods using TEC estimates obtained by a regional GPS network. It is observed that noon time depletions in TEC distributions predominantly occur in winter for minimum Sun Spots Numbers (SSN) in the central regions of Turkey which also exhibit high variability due to midlatitude winter anomaly. TEC values and ionospheric variations at solstice periods demonstrate significant enhancements compared to those at equinox periods.
Martínez-Flores, Héctor Eduardo; Garnica-Romo, Ma. Guadalupe; Padilla-Ramírez, José Saúl; Saavedra-Molina, Alfredo; Alvarez-Cortes, Osvaldo; Bartolomé-Camacho, María Carmen; Rodiles-López, José Octavio
2018-01-01
Guava leaf (Psidium guajava L.) extracts are used in both traditional medicine and the pharmaceutical industry. The antioxidant compounds in P. guajava leaves can have positive effects including anti-inflammatory, anti-hyperglycemic, hepatoprotective, analgesic, anti-cancer effects, as well as protecting against cardiovascular diseases. In the present study, phenolic compounds and in vitro antioxidant capacity were measured in extracts obtained with polar and non-polar solvents from leaves of two varieties of guava, Calvillo Siglo XXI and Hidrozac. The quantity of total phenolics and total flavonoids were expressed as equivalents of gallic acid and quercetin, respectively. Hydroxyl radical, 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) (ABTS), 2,2-diphenyl-1-picrylhydrazyl (DPPH), and Oxygen Radical Absorbance Capacity using fluorescein (ORAC-FL) in vitro tests were used to assess the radical scavenging abilities of the extracts. The total phenolics were higher in the aqueous fraction of the variety Calvillo Siglo XXI, while in the Hidrozac variety total phenolics were higher in the acetone and chloroform fractions. Total flavonoids were higher in all fractions in the variety Calvillo Siglo XXI. Total phenolics showed a highly positive correlation for ORAC-FL, and a moderately positive correlation with hydroxyl radicals. Finally, total flavonoids showed a slightly positive correlation for ORAC-FL and hydroxyl radicals. Both varieties of guava leaf extract showed excellent antioxidant properties. PMID:29495514
Camarena-Tello, Julio César; Martínez-Flores, Héctor Eduardo; Garnica-Romo, Ma Guadalupe; Padilla-Ramírez, José Saúl; Saavedra-Molina, Alfredo; Alvarez-Cortes, Osvaldo; Bartolomé-Camacho, María Carmen; Rodiles-López, José Octavio
2018-02-27
Guava leaf ( Psidium guajava L.) extracts are used in both traditional medicine and the pharmaceutical industry. The antioxidant compounds in P. guajava leaves can have positive effects including anti-inflammatory, anti-hyperglycemic, hepatoprotective, analgesic, anti-cancer effects, as well as protecting against cardiovascular diseases. In the present study, phenolic compounds and in vitro antioxidant capacity were measured in extracts obtained with polar and non-polar solvents from leaves of two varieties of guava, Calvillo Siglo XXI and Hidrozac. The quantity of total phenolics and total flavonoids were expressed as equivalents of gallic acid and quercetin, respectively. Hydroxyl radical, 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) (ABTS), 2,2-diphenyl-1-picrylhydrazyl (DPPH), and Oxygen Radical Absorbance Capacity using fluorescein (ORAC-FL) in vitro tests were used to assess the radical scavenging abilities of the extracts. The total phenolics were higher in the aqueous fraction of the variety Calvillo Siglo XXI, while in the Hidrozac variety total phenolics were higher in the acetone and chloroform fractions. Total flavonoids were higher in all fractions in the variety Calvillo Siglo XXI. Total phenolics showed a highly positive correlation for ORAC-FL, and a moderately positive correlation with hydroxyl radicals. Finally, total flavonoids showed a slightly positive correlation for ORAC-FL and hydroxyl radicals. Both varieties of guava leaf extract showed excellent antioxidant properties.
Fine-Scale Comparison of TOMS Total Ozone Data with Model Analysis of an Intense Midwestern Cyclone
NASA Technical Reports Server (NTRS)
Olsen, Mark A.; Gallus, William A., Jr.; Stanford, John L.; Brown, John M.
2000-01-01
High-resolution (approx. 40 km) along-track total column ozone data from the Total Ozone Mapping Spectrometer (TOMS) instrument are compared with a high-resolution mesoscale numerical model analysis of an intense cyclone in the Midwestern United States. Total ozone increased by 100 DU (nearly 38%) as the TOMS instrument passed over the associated tropopause fold region. Complex structure is seen in the meteorological fields and compares well with the total ozone observations. Ozone data support the meteorological analysis showing that stratospheric descent was confined to levels above approx. 600 hPa; significant positive potential vorticity at lower levels is attributable to diabetic processes. Likewise, meteorological fields show that two pronounced ozone streamers extending north and northeastward into Canada at high levels are not bands of stratospheric air feeding into the cyclone; one is a channel of exhaust downstream from the system, and the other apparently previously connected the main cyclonic circulation to a southward intrusion of polar stratospheric air and advected eastward as the cut-off cyclone evolved. Good agreement between small-scale features in the model output and total ozone data underscores the latter's potential usefulness in diagnosing upper tropospheric/lower stratospheric dynamics and kinematics.
CHANGES IN BACTERIAL COMPOSITION OF BIOFILM IN A ...
This study examined the development of bacterial biofilms within a metropolitan distribution system. The distribution system is fed with different source water (i.e., groundwater, GW and surface water, SW) and undergoes different treatment processes in separate facilities. The biofilm community was characterized using 16S rRNA gene clone libraries and functional potential analysis, generated from total DNA extracted from coupons in biofilm annular reactors fed with onsite drinking water for up to eighteen months. Significant differences in the bacterial community structure were observed between GW and SW. Representatives that explained the dissimilarity between service areas were associated with Betaproteobacteria, Alphaproteobacteria, Actinobacteria, Gammaproteobacteria, and Firmicutes. After nine months the biofilm bacterial community from both areas were dominated by Mycobacterium species. The distribution of the dominant OTU (Mycobacterium) positively correlated with the drinking water distribution system (DWDS) temperature, but no clear relationship was seen with free chlorine residual, pH, turbidity or total organic carbon (TOC). The results suggest that biofilm microbial communities harbor distinct and diverse bacterial communities, and that source water, treatment processes and environmental conditions may play an important role in shaping the bacterial community in the distribution system. On the other hand, several bacterial groups were present i
Frequency modulation television analysis: Threshold impulse analysis. [with computer program
NASA Technical Reports Server (NTRS)
Hodge, W. H.
1973-01-01
A computer program is developed to calculate the FM threshold impulse rates as a function of the carrier-to-noise ratio for a specified FM system. The system parameters and a vector of 1024 integers, representing the probability density of the modulating voltage, are required as input parameters. The computer program is utilized to calculate threshold impulse rates for twenty-four sets of measured probability data supplied by NASA and for sinusoidal and Gaussian modulating waveforms. As a result of the analysis several conclusions are drawn: (1) The use of preemphasis in an FM television system improves the threshold by reducing the impulse rate. (2) Sinusoidal modulation produces a total impulse rate which is a practical upper bound for the impulse rates of TV signals providing the same peak deviations. (3) As the moment of the FM spectrum about the center frequency of the predetection filter increases, the impulse rate tends to increase. (4) A spectrum having an expected frequency above (below) the center frequency of the predetection filter produces a higher negative (positive) than positive (negative) impulse rate.
Wu, Yuangang; Yang, Timin; Zeng, Yi; Si, Haibo; Li, Canfeng; Shen, Bin
2017-01-01
Postoperative limb positioning has been reported to be an efficient and simple way to reduce blood loss and improve range of motion following total knee arthroplasty (TKA). This meta-analysis was designed to compare the effectiveness of two different limb positions in primary TKA. A meta-analysis of the PubMed, CENTRAL, Web of Science, EMBASE and Google Search Engine electronic databases was performed. In this meta-analysis, two postoperative limb positions were considered: mild-flexion (flexion less than 60°) and high-flexion (flexion at 60° or more). The subgroups were analysed using RevMan 5.3. Nine RCTs were included with a total sample size of 913 patients. The mild- and high-flexion positions significantly reduced postoperative total blood loss (P = 0.04 and P = 0.01; respectively). Subgroup analysis indicated that knee flexion significantly reduced hidden blood loss when the knee was fixed in mild-flexion (P = 0.0004) and significantly reduced transfusion requirements (P = 0.03) and improved range of motion (ROM) (P < 0.00001) when the knee was fixed in high-flexion. However, the rates of wound-related infection, deep venous thrombosis (DVT) and pulmonary embolism (PE) did not significantly differ between the two flexion groups. This meta-analysis suggests that mild- and high-flexion positions have similar efficacy in reducing total blood loss. In addition, subgroup analysis indicates that the mild-flexion position is superior in decreasing hidden blood loss compared with high-flexion; the high-flexion position is superior to mild-flexion in reducing transfusion requirements and improving postoperative ROM. Thus, the use of the high-flexion position is a viable option to reduce blood loss in patients following primary TKA without increasing the risk of wound-related infection, DVT or PE. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Space Interferometry Mission: Dynamical Observations of Galaxies (SIMDOG)
NASA Technical Reports Server (NTRS)
Shaya, Edward J.; Borne, Kirk D.; Nusser, Adi; Peebles, P. J. E.; Tonry, John; Tully, Brent R.; Vogel, Stuart; Zaritsky, Dennis
2004-01-01
Space Interferometry Mission (SIM) will be used to obtain proper motions for a sample of 27 galaxies; the first proper motion measurements of galaxies beyond the satellite system of the Milky Way. SIM measurements lead to knowledge of the full 6-dimensional position and velocity vector of each galaxy. In conjunction with new gravitational flow models, the result will be the first total mass measurements of individual galaxies. The project, includes developnient of powerful theoretical methods for orbital calculations. This SIM study will lead to vastly improved determinations of individual galaxy masses, halo sizes, and the fractional contribution of dark matter. Astronomers have struggled to calculate the orbits of galaxies with only position and redshift information. Traditional N-body techniques are unsuitable for an analysis backward in time from a present distribution if any components of velocity or position are not very precisely known.
Improvement of the prompt-gamma neutron activation facility at Brookhaven National Laboratory.
Dilmanian, F A; Lidofsky, L J; Stamatelatos, I; Kamen, Y; Yasumura, S; Vartsky, D; Pierson, R N; Weber, D A; Moore, R I; Ma, R
1998-02-01
The prompt-gamma neutron activation facility at Brookhaven National Laboratory was upgraded to improve both the precision and accuracy of its in vivo determinations of total body nitrogen. The upgrade, guided by Monte Carlo simulations, involved elongating and modifying the source collimator and its shielding, repositioning the system's two NaI(Tl) detectors, and improving the neutron and gamma shielding of these detectors. The new source collimator has a graphite reflector around the 238PuBe neutron source to enhance the low-energy region of the neutron spectrum incident on the patient. The gamma detectors have been relocated from positions close to the upward-emerging collimated neutron beam to positions close to and at the sides of the patient. These modifications substantially reduced spurious counts resulting from the capture of small-angle scattered neutrons in the NaI detectors. The pile-up background under the 10.8 MeV 14N(n, gamma)15N spectral peak has been reduced so that the nitrogen peak-to-background ratio has been increased by a factor of 2.8. The resulting reduction in the coefficient of variation of the total body nitrogen measurements from 3% to 2.2% has improved the statistical significance of the results possible for any given number of patient measurements. The new system also has a more uniform composite sensitivity.
Jump, Robin L. P.; Olds, Danielle M.; Seifi, Nasim; Kypriotakis, Georgios; Jury, Lucy A.; Peron, Emily P.; Hirsch, Amy A.; Drawz, Paul E.; Watts, Brook; Bonomo, Robert A.; Donskey, Curtis J.
2014-01-01
Design We introduced a long-term care facility (LTCF) Infectious Disease (ID) consult service (LID) that provides on-site consultations to residents of a VA LTCF. We determined the impact of the LID service on antimicrobial use and Clostridium difficile infections at the LTCF. Setting A 160-bed Veterans Affairs (VA) LTCF. Methods Systemic antimicrobial use and the rate of positive C. difficile tests at the LTCF were compared for 36 months before and 18 months after the initiation of the ID consultation service using segmented regression analysis of an interrupted time-series. Results In contrast to the pre-intervention period, total systemic antibiotic administration decreased by 30% (P <.001) with a significant reduction in both oral (32%; P<.001) and intravenous agents (25%; P =.008). The greatest reductions were seen for tetracyclines (64%, P <.001), clindamycin (61%; P <.001), sulfamethoxazole/trimethoprim (38%; P <.001), fluoroquinolones (38%; P <.001) and beta-lactam/beta-lactamase inhibitor combinations (28%; P <.001). Rates of change for positive C. difficile tests at the LTCF declined in the post- vs. preintervention periods (P = .04). Conclusions Implementation of a LTCF ID service led to a significant reduction in total antimicrobial use. Bringing providers with infectious disease expertise to the LTCF represents a new and effective means to achieve antimicrobial stewardship. PMID:23143354
Seyeddain, Orang; Kraker, Hannes; Redlberger, Andreas; Dexl, Alois K; Grabner, Günther; Emesz, Martin
2014-01-01
To investigate the reliability of a biometric iris recognition system for personal authentication after cataract surgery or iatrogenic pupil dilation. This was a prospective, nonrandomized, single-center, cohort study for evaluating the performance of an iris recognition system 2-24 hours after phacoemulsification and intraocular lens implantation (group 1) and before and after iatrogenic pupil dilation (group 2). Of the 173 eyes that could be enrolled before cataract surgery, 164 (94.8%) were easily recognized postoperatively, whereas in 9 (5.2%) this was not possible. However, these 9 eyes could be reenrolled and afterwards recognized successfully. In group 2, of a total of 184 eyes that were enrolled in miosis, a total of 22 (11.9%) could not be recognized in mydriasis and therefore needed reenrollment. No single case of false-positive acceptance occurred in either group. The results of this trial indicate that standard cataract surgery seems not to be a limiting factor for iris recognition in the large majority of cases. Some patients (5.2% in this study) might need "reenrollment" after cataract surgery. Iris recognition was primarily successful in eyes with medically dilated pupils in nearly 9 out of 10 eyes. No single case of false-positive acceptance occurred in either group in this trial. It seems therefore that iris recognition is a valid biometric method in the majority of cases after cataract surgery or after pupil dilation.
NASA Astrophysics Data System (ADS)
Wei, Qingyang; Ma, Tianyu; Xu, Tianpeng; Zeng, Ming; Gu, Yu; Dai, Tiantian; Liu, Yaqiang
2018-01-01
Modern positron emission tomography (PET) detectors are made from pixelated scintillation crystal arrays and readout by Anger logic. The interaction position of the gamma-ray should be assigned to a crystal using a crystal position map or look-up table. Crystal identification is a critical procedure for pixelated PET systems. In this paper, we propose a novel crystal identification method for a dual-layer-offset LYSO based animal PET system via Lu-176 background radiation and mean shift algorithm. Single photon event data of the Lu-176 background radiation are acquired in list-mode for 3 h to generate a single photon flood map (SPFM). Coincidence events are obtained from the same data using time information to generate a coincidence flood map (CFM). The CFM is used to identify the peaks of the inner layer using the mean shift algorithm. The response of the inner layer is deducted from the SPFM by subtracting CFM. Then, the peaks of the outer layer are also identified using the mean shift algorithm. The automatically identified peaks are manually inspected by a graphical user interface program. Finally, a crystal position map is generated using a distance criterion based on these peaks. The proposed method is verified on the animal PET system with 48 detector blocks on a laptop with an Intel i7-5500U processor. The total runtime for whole system peak identification is 67.9 s. Results show that the automatic crystal identification has 99.98% and 99.09% accuracy for the peaks of the inner and outer layers of the whole system respectively. In conclusion, the proposed method is suitable for the dual-layer-offset lutetium based PET system to perform crystal identification instead of external radiation sources.
COMPARISON OF RECENTLY USED PHACOEMULSIFICATION SYSTEMS USING A HEALTH TECHNOLOGY ASSESSMENT METHOD.
Huang, Jiannan; Wang, Qi; Zhao, Caimin; Ying, Xiaohua; Zou, Haidong
2017-01-01
To compare the recently used phacoemulsification systems using a health technology assessment (HTA) model. A self-administered questionnaire, which included questions to gauge on the opinions of the recently used phacoemulsification systems, was distributed to the chief cataract surgeons in the departments of ophthalmology of eighteen tertiary hospitals in Shanghai, China. A series of senile cataract patients undergoing phacoemulsification surgery were enrolled in the study. The surgical results and the average costs related to their surgeries were all recorded and compared for the recently used phacoemulsification systems. The four phacoemulsification systems currently used in Shanghai are the Infiniti Vision, Centurion Vision, WhiteStar Signature, and Stellaris Vision Enhancement systems. All of the doctors confirmed that the systems they used would help cataract patients recover vision. A total of 150 cataract patients who underwent phacoemulsification surgery were enrolled in the present study. A significant difference was found among the four groups in cumulative dissipated energy, with the lowest value found in the Centurion group. No serious complications were observed and a positive trend in visual acuity was found in all four groups after cataract surgery. The highest total cost of surgery was associated with procedures conducted using the Centurion Vision system, and significant differences between systems were mainly because of the cost of the consumables used in the different surgeries. This HTA comparison of four recently used phacoemulsification systems found that each of system offers a satisfactory vision recovery outcome, but differs in surgical efficacy and costs.
A smartphone-based system for the automated management of point-of-care test results in hospitals.
Jang, Dasom; Shin, Soo-Yong; Seo, Dong-Woo; Joo, Segyeong; Huh, Soo-Jin
2015-04-01
Managing test results is an important issue in hospitals because of the increasing use of point-of-care testing (POCT). Here, we propose a smartphone-based system for automatically managing POCT test results. We developed the system to provide convenience to the medical staffs. The system recognizes the patient identification or prescription number of the test by reading barcodes and provides a countdown to indicate when the results will be ready. When the countdown in finished, a picture of the test result is transferred to the electronic medical record server using the Health Level 7 protocol. Human immunodeficiency virus (HIV) kits were selected in this research because HIV is a life-threatening infectious virus, especially for the medical staff who treat undiagnosed patients. The performance of the system was verified from a survey of the users. The performance of the system was tested at the emergency room (ER) for 10 months using commercially available POCT kits for detecting HIV. The survey showed that, in total, 80% and 0% of users reported positive or negative feedback, respectively. The staff also reported that the system reduced total processing time by approximately 32 min, in addition to reducing workload. The developed automated management system was successfully tested at an ER for 10 months. The survey results show that the system is effective and that medical staff members who used the system are satisfied with using the system at the ER.
Liang, Jing-Bo; Liu, Li-Jin; Fang, Qiu-Hong
2017-05-01
The clinical characteristics of patients with chronic obstructive pulmonary disease overlapped with bronchial asthma (COPD-BA) have not been discussed thoroughly. To reveal the clinical features of patients with COPD-BA, to evaluate the risk factors of COPD-BA, and to provide suggestions for COPD individualized therapy. A retrospective observational study was performed. A total of 182 patients with COPD (90 with COPD-BA and 92 with pure COPD) were recruited in the study. Information on the following items was collected: demographics, clinical manifestations, complications, laboratory findings, other histories, and inpatient treatments during exacerbation. A total of 182 patients were diagnosed with COPD, with 90 (49.45%) being classified as having COPD-BA. Patients with COPD-BA were more likely to be female (P = .004) and experienced more severe respiratory exacerbations (P = .04) despite being younger (P = .008). Those patients at onset of recurrent cough and sputum production were younger (P = .001). Significantly, a positive asthmatic family history (P = .03) was observed. Patients with COPD-BA usually had higher level of total serum IgE (although no differences were observed), had higher positive rates of the serum specific IgE (P = .004), and were more like to have an allergic history (P = .003). Allergic factor was the risk factor of COPD-BA (odds ratio, 4.477). During hospitalization, patients with COPD-BA tended to be treated with systemic corticosteroids (P = .008). Patients with COPD-BA were characterized by persistent airflow limitation with unique clinical features. Allergic factor was associated with the presence of asthmatic characteristics in patients with COPD. When hospitalized for exacerbation, the individualized therapy for COPD-BA might include the use of corticosteroids systemically. Copyright © 2017 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Assessment of biological effects of chlorinated hydrocarbons in osprey chicks
Elliott, J.E.; Wilson, L.K.; Henny, Charles J.; Trudeau, Suzanne F.; Leighton, Frederick A.; Kennedy, Sean W.; Cheng, Kimberly M.
2001-01-01
Osprey (Pandion haliaetus) eggs were collected during 1995 and 1996 at seven sites along the Fraser and Columbia River systems of British Columbia, Canada, and Washington and Oregon, USA. Fifty-four eggs were placed into a laboratory incubator. Thirty-eight of the hatched chicks were sacrificed within 24 h. Hatching success did not differ among sites and therefore between treatment and reference areas. Residual yolk sacs of eggs collected downstream of the large bleached-kraft pulp mill at Castlegar contained greater mean concentrations of 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD, 2,930 ng/kg lipid) compared with reference sites such as the Nechako River, an upper tributary of the Fraser system (33.7 ng/kg). Total polychlorinated biphenyls (PCBs) in yolk sacs were also higher at Castlegar and in samples from the Columbia River downstream of Portland, Oregon, compared with those from the Nechako River. Concentrations of measured chemicals, including TCDD toxic equivalents (TEQs), total PCBs, p,pa??-dichlorodiphenylethylene (p,pa??-DDE), and other organochlorines were not different in eggs that failed to hatch compared with calculated whole-egg values for hatched eggs. There were significant biochemical responses; a hepatic cytochrome P4501A (CYP1A) cross-reactive protein was detected in all samples tested and correlated positively with ethoxyresorufin o-deethylase (EROD) activity and yolk sac concentrations of TEQs and total PCBs. Tissue concentrations of vitamin A compounds varied among sites and correlated positively with yolk sac concentrations of TEQs and PCBs. Morphological, histological, and other physiological parameters, including chick growth, edema, deformities, and hepatic and renal porphyrin concentrations, neither varied among sites nor showed concentration-related effects.
Plumbing system shock absorbers as a source of Legionella pneumophila.
Memish, Z A; Oxley, C; Contant, J; Garber, G E
1992-12-01
Water distribution systems have been demonstrated to be a major source of nosocomial legionellosis. We describe an outbreak in our institution in which a novel source of Legionella pneumophila was identified in the plumbing system. After an outbreak of 10 cases of legionellosis in our hospital, recommended measures including superheating of the hot water to 80 degrees C, hyperchlorination to 2 ppm, and flushing resulted in no new cases in the following 5 years. Recently, despite these control measures, three new cases occurred. Surveillance cultures of shower heads and water tanks were negative; cultures of tap water samples remained positive. This prompted a search for another reservoir. Shock absorbers installed within water pipes to decrease noise were suspected. One hundred twenty-five shock absorbers were removed and cultured. A total of 13 (10%) yielded heavy growth of L. pneumophila (serogroup 1). Since their removal, no new cases have been found and the percentage of positive results of random tap water culture has dropped from 20% to 5%. This is the first report that identifies shock absorbers as a possible reservoir for L. pneumophila. We recommend that institutions with endemic legionellosis assess the water system for possible removal of shock absorbers.
Larghi, O P; Nebel, A E; Lazaro, L; Savy, V L
1975-01-01
A tissue culture system for detecting rabies virus from saliva samples of suspected animals was developed and compared to suckling mouse inoculation. Swab samples were obtained from the mouth of the animal heads received for rabies diagnosis; these swabs were submerged in maintenance medium. The maintenance medium was inoculated intracerebrally into suckling mice and onto BHK-21 cells with diethylaminoethyl (DEAE)-dextran (BHK/DEAE) and without (BHK). Rabies immunofluorescence was performed on the brain of the mice dying during the observation period and also on both tissue culture systems every day after infection. The BHK-DEAE system detected 28 positive samples obtained from 48 rabid animals and the BHK system detected 18. By suckling mouse inoculation only 11 of the same positive samples were detected. A total of 90 samples was studied by the three methods. Rabies virus was detected by the tissue culture methods earlier than by suckling mouse inoculation. The BHK-DEAE method was an economic and fast method for rabies virus detection in saliva samples, which could be used for ecological and pathogenesis studies, as well for rabies diagnosis before the death of the suspected animal. PMID:1100655
Barber, Catherine; Azrael, Deborah; Cohen, Amy; Miller, Matthew; Thymes, Deonza; Wang, David Enze; Hemenway, David
2016-05-01
To evaluate the National Violent Death Reporting System (NVDRS) as a surveillance system for homicides by law enforcement officers. We assessed sensitivity and positive predictive value of the NVDRS "type of death" variable against our study count of homicides by police, which we derived from NVDRS coded and narrative data for states participating in NVDRS 2005 to 2012. We compared state counts of police homicides from NVDRS, Vital Statistics, and Federal Bureau of Investigation Supplementary Homicide Reports. We identified 1552 police homicides in the 16 states. Positive predictive value and sensitivity of the NVDRS "type of death" variable for police homicides were high (98% and 90%, respectively). Counts from Vital Statistics and Supplementary Homicide Reports were 58% and 48%, respectively, of our study total; gaps varied widely by state. The annual rate of police homicide (0.24/100,000) varied 5-fold by state and 8-fold by race/ethnicity. NVDRS provides more complete data on police homicides than do existing systems. Expanding NVDRS to all 50 states and making 2 improvements we identify will be an efficient way to provide the nation with more accurate, detailed data on homicides by law enforcement.
Liu, Shuli; Zhang, Guangming; Zhang, Jie; Li, Xiangkun; Li, Jianzheng
2016-01-01
Effects of hydraulic retention time (HRT) and influent organic loading rate (OLR) were investigated in a photobioreactor containing PNSB (Rhodopseudomonas palustris)-chemoheterotrophic bacteria to treat volatile fatty acid wastewater. Pollutants removal, biomass production and carotenoids yield in different phases were investigated in together with functional microbial population dynamics. The results indicated that properly decreasing HRT and increasing OLR improved the nutrient removal performance as well as the biomass and carotenoids productions. 85.7% COD, 89.9% TN and 91.8% TP removals were achieved under the optimal HRT of 48h and OLR of 2.51g/L/d. Meanwhile, the highest biomass production and carotenoids yield were 2719.3mg/L and 3.91mg/g-biomass respectively. In addition, HRT and OLR have obvious impacts on PNSB and total bacteria dynamics. Statistical analyses indicated that the COD removal exhibited a positive relationship with OLR, biomass and carotenoids production. PNSB/total bacteria ratio had a positive correlation with the carotenoids yield. Copyright © 2015 Elsevier Ltd. All rights reserved.
A revised lens time delay for JVAS B0218+357 from a reanalysis of VLA monitoring data
NASA Astrophysics Data System (ADS)
Biggs, A. D.; Browne, I. W. A.
2018-06-01
We have reanalysed the 1996/1997 Very Large Array monitoring data of the gravitational lens system JVAS B0218+357 to produce improved total flux density and polarization variability curves at 15, 8.4, and 5 GHz. This has been done using improved calibration techniques, accurate subtraction of the emission from the Einstein ring, and careful correction of various systematic effects, especially an offset in polarization position angle that is hour-angle dependent. The variations in total and polarized flux density give the best constraints and we determine a combined delay estimate of 11.3 ± 0.2 d (1σ). This is consistent with the γ-ray value recently derived using the Fermi Gamma-ray Space Telescope and thus we find no evidence for a positional shift between the radio and γ-ray emitting regions. Combined with the previously published lens model found using LENSCLEAN, the new delay gives a value for the Hubble constant of H0 = 72.9 ± 2.6 km s-1 Mpc-1 (1σ).
Atomic displacements in the charge ice pyrochlore Bi2Ti2O6O' studied by neutron total scattering
NASA Astrophysics Data System (ADS)
Shoemaker, Daniel P.; Seshadri, Ram; Hector, Andrew L.; Llobet, Anna; Proffen, Thomas; Fennie, Craig J.
2010-04-01
The oxide pyrochlore Bi2Ti2O6O' is known to be associated with large displacements of Bi and O' atoms from their ideal crystallographic positions. Neutron total scattering, analyzed in both reciprocal and real space, is employed here to understand the nature of these displacements. Rietveld analysis and maximum entropy methods are used to produce an average picture of the structural nonideality. Local structure is modeled via large-box reverse Monte Carlo simulations constrained simultaneously by the Bragg profile and real-space pair distribution function. Direct visualization and statistical analyses of these models show the precise nature of the static Bi and O' displacements. Correlations between neighboring Bi displacements are analyzed using coordinates from the large-box simulations. The framework of continuous symmetry measures has been applied to distributions of O'Bi4 tetrahedra to examine deviations from ideality. Bi displacements from ideal positions appear correlated over local length scales. The results are consistent with the idea that these nonmagnetic lone-pair containing pyrochlore compounds can be regarded as highly structurally frustrated systems.
NASA Astrophysics Data System (ADS)
Yesilgul, U.; Al, E. B.; Martínez-Orozco, J. C.; Restrepo, R. L.; Mora-Ramos, M. E.; Duque, C. A.; Ungan, F.; Kasapoglu, E.
2016-08-01
In the present study, the effects of electric and magnetic fields on the linear and third-order nonlinear optical absorption coefficients and relative change of the refractive index in asymmetric GaAs/GaAlAs double quantum wells under intense laser fields are theoretically investigated. The electric field is oriented along the growth direction of the heterostructure while the magnetic field is taken in-plane. The intense laser field is linear polarization along the growth direction. Our calculations are made using the effective-mass approximation and the compact density-matrix approach. Intense laser effects on the system are investigated with the use of the Floquet method with the consequent change in the confinement potential of heterostructures. Our results show that the increase of the electric and magnetic fields blue-shifts the peak positions of the total absorption coefficient and of the total refractive index while the increase of the intense laser field firstly blue-shifts the peak positions and later results in their red-shifting.
Coyago-Cruz, Elena; Corell, Mireia; Moriana, Alfonso; Hernanz, Dolores; Stinco, Carla M; Meléndez-Martínez, Antonio J
2017-10-01
Cherry tomato varieties are widely consumed in many countries. They contain nutrients and health-promoting compounds like phenolics and carotenoids. The main purpose of this study was to determine how the fruit position on the cluster affected quality parameters of diverse nature (weight, soluble solids, firmness, colour, carotenoids, phenolic compounds and sugars). For this purpose the fourth cluster of two cherry varieties (Summerbrix and Lazarino) were studied. The results indicated that the fruit position on the cluster decreased the fruit size between 14 and 16% and weight 40%; firmness in 'Lazarino' increased 56%; C* ab increased 12% in 'Lazarino' and decreased 13% in 'Summerbrix'; h ab increased 9% in 'Summerbrix'. Total carotenoid levels were not statistically different in two positions, and in the other position the contents were higher, with a difference of 36% between these two values. The highest total phenolic levels were observed in the PII position. However, total sugars increased 36%, fructose 36% and glucose 35% from the PI to PIII position in 'Lazarino', while, in 'Summerbrix' higher values were observed in the PIII position. Copyright © 2017 Elsevier Ltd. All rights reserved.
Busetto, Gian Maria; Ferro, Matteo; Del Giudice, Francesco; Antonini, Gabriele; Chung, Benjamin I; Sperduti, Isabella; Giannarelli, Diana; Lucarelli, Giuseppe; Borghesi, Marco; Musi, Gennaro; de Cobelli, Ottavio; De Berardinis, Ettore
2017-08-01
The purpose of this study was to evaluate the impact of circulating tumor cells (CTCs) as a prognostic marker in patients with high-risk non-muscle-invasive bladder cancer (NMIBC) and assess the efficacy and reliability of 2 different CTC isolation methods. Globally, 155 patients with a pathologically confirmed diagnosis of high-risk NMIBC were included (pT1G3 with or without carcinoma in situ) and underwent transurethral resection of bladder tumor (TURB) after a blood withdrawal for CTC evaluation. A total of 101 patients (Group A) had their samples analyzed with the CellSearch automated system, and 54 (Group B) had their samples analyzed with the CELLection Dynabeads manual system. Patients were followed for 28 months, and during this interval, there were a total of 65 (41.9%) recurrences, 27 (17.4%) disease progressions, and 9 (5.8%) lymph node and/or bone metastasis. In our CTC analysis, there were 20 (19.8%) positive patients in Group A and 24 in Group B (44.4%). In our analysis, we found a strong correlation between CTC presence and time to first recurrence; in Group A, we observed an incidence of recurrence in 75% of CTC-positive patients and in Group B of 83% of CTC-positive patients. The time to progression was also strongly correlated with CTCs: 65% and 29%, respectively, of those patients who progressed in those with CTCs in Group A and B. The study demonstrates the potential role of CTCs as a prognostic marker for risk stratification in patients with NMIBC, to predict both recurrence and progression. Copyright © 2017 Elsevier Inc. All rights reserved.
SU-F-J-37: Commissioning a Six Degree of Freedom Couch
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberts, D; Lam, K; Bredfeldt, J
2016-06-15
Purpose: The proper operation of a six degree of freedom couch (6DOFC) to position a patient for treatment requires that a number systems on the treatment unit work together correctly. Commissioning a 6DOFC requires not only the commissioning of each separate system but also commissioning the interactions between the systems. Methods: To commission a 6DOFC, we tested the resolvers that readout the linear and angular positions; the orthogonality of the axes of the laser positioning system, the imaging system, the gantry and the couch as well as their relationship to each other. An automated Winston-Lutz test was used verify themore » coincidence of the origins of the laser system, imaging system and treatment unit. The IsoCal phantom was used to verify the consistency of axes orientations between systems. The operation of the couch and imaging system was verified under simulated load conditions and an end to end test was performed to verify correct operation of the system. Results: The tests on the couch resolvers, orthogonality and coincidence of the axes of each system were successfully completed and showed excellent agreement. The automated Winston-Lutz test showed that the maximum displacement of the center of the radiation field with respect to the isocenter was <0.6 mm (radius) at isocenter. The analysis of the IsoCal phantom showed that the maximum variation of the radiation field with respect to known locations in the phantom was ∼0.9 mm for all the BBs in the phantom. Load tests showed maximum errors of 1 mm. Conclusion: We tested all system associated with the 6DOFC and found the uncertainty due to imaging was <.9mm and the uncertainty due to loading ∼1 mm, resulting in a total error of ∼1.4 mm.« less
Li, Min; Zhong, Guo-yue; Wu, Ao-lin; Zhang, Shou-wen; Jiang, Wei; Liang, Jian
2015-05-01
To explore the correlation between the ecological factors and the contents of podophyllotoxin and total lignans in root and rhizome of Sinopodophyllum hexandrum, podophyllotoxin in 87 samples (from 5 provinces) was determined by HPLC and total lignans by UV. A correlation and regression analysis was made by software SPSS 16.0 in combination with ecological factors (terrain, soil and climate). The content determination results showed a great difference between podophyllotoxin and total lignans, attaining 1.001%-6.230% and 5.350%-16.34%, respective. The correlation and regression analysis by SPSS showed a positive linear correlation between their contents, strong positive correlation between their contents, latitude and annual average rainfall within the sampling area, weak negative correlation with pH value and organic material in soil, weaker and stronger positive correlations with soil potassium, weak negative correlation with slope and annual average temperature and weaker positive correlation between the podophyllotoxin content and soil potassium.
Integration mechanisms and hospital efficiency in integrated health care delivery systems.
Wan, Thomas T H; Lin, Blossom Yen-Ju; Ma, Allen
2002-04-01
This study analyzes integration mechanisms that affect system performances measured by indicators of efficiency in integrated delivery systems (IDSs) in the United States. The research question is, do integration mechanisms improve IDSs' efficiency in hospital care? American Hospital Association's Annual Survey (1998) and Dorenfest's Survey on Information Systems in Integrated Healthcare Delivery Systems (1998) were used to conduct the study, using IDS as the unit of analysis. A covariance structure equation model of the effects of system integration mechanisms on IDS performance was formulated and validated by an empirical examination of IDSs. The study sample includes 973 hospital-based integrated health care delivery systems operating in the United States, carried in the list of Dorenfests Survey on Information Systems in Integrated Health care Delivery Systems. The measurement indicators of system integration mechanisms are categorized into six related domains: informatic integration, case management, hybrid physician-hospital integration, forward integration, backward integration, and high tech medical services. The multivariate analysis reveals that integration mechanisms in system operation are positively correlated and positively affect IDSs' efficiency. The six domains of integration mechanisms account for 58.9% of the total variance in hospital performance. The service differentiation strategy such as having more high tech medical services have much stronger influences on efficiency than other integration mechanisms do. The beneficial effects of integration mechanisms have been realized in IDS performance. High efficiency in hospital care can be achieved by employing proper integration strategies in operations.
The movement characteristics of English Premiership rugby union players.
Cahill, Nicola; Lamb, Kevin; Worsfold, Paul; Headey, Roy; Murray, Stafford
2013-01-01
The purpose of this investigation was to quantify the movement characteristics of elite rugby union players during competitive play and identify whether position-related differences exist. Ninety-eight elite players from eight English Premiership Clubs were tracked using global positioning systems (GPS) during 44 competitive matches throughout the 2010/2011 season. Player positions were defined as: (1) backs or forwards; (2) front, second and back rows, scrum half, inside and outside backs; (3) 15 individual positions (numbers 1-15). Analysis revealed the game is predominantly played at low speeds with little distance covered 'sprinting' by either the backs (50 ± 76 m) or the forwards (37 ± 64 m). The backs travelled greater (P < 0.05) absolute and relative distances than the forwards. The scrum half covered the greatest total distance during a match (7098 ± 778 m) and the front row the least (5158 ± 200 m). The back row covered the greatest distances at 'sprinting' speeds, particularly the number 8 position (77 m). These findings reflect notable differences in the movement characteristics displayed by elite rugby union players in specific positional roles, and reinforce the contemporary view that training programmes for such players ought to be structured with this in mind.
Quinn, Celia; Demirjian, Alicia; Watkins, Louise Francois; Tomczyk, Sara; Lucas, Claressa; Brown, Ellen; Kozak-Muiznieks, Natalia; Benitez, Alvaro; Garrison, Laurel E; Kunz, Jasen; Brewer, Scott; Eitniear, Samantha; DiOrio, Mary
2015-12-01
On July 9, 2013, an outbreak of Legionnaires' disease (LD) was identified at Long-Term Care Facility A in central Ohio. This article describes the investigation of the outbreak and identification of the outbreak source, a cooling tower using an automated biocide delivery system. In total, 39 outbreak LD cases were identified; among these, six patients died. Water samples from a cooling tower were positive for Legionella pneumophila serogroup 1, reactive to monoclonal antibody 2, with matching sequence type to a patient isolate. An electronic control system turned off cooling tower pumps during low-demand periods, preventing delivery of disinfectant by a timed-release system, and leading to amplification of Legionella in the cooling tower. Guidelines for tower maintenance should address optimal disinfection when using automated systems.
Raabe, E.A.; Stumpf, R.P.; Marth, N.J.; Shrestha, R.L.
1996-01-01
Elevation differences on the order of 10 cm within Florida's marsh system influence major variations in tidal flooding and in the associated plant communities. This low elevation gradient combined with sea level fluctuation of 5-to-10 cm over decadel and longer periods can generate significant alteration and erosion of marsh habitats along the Gulf Coast. Knowledge of precise and accurate elevations in the marsh is critical to the efficient monitoring and management of these habitats. Global positioning system (GPS) technology was employed to establish six new orthometric heights along the Gulf Coast from which kinematic surveys into the marsh interior are conducted. The vertical accuracy achieved using GPS technology was evaluated using two networks with 16 vertical and nine horizontal NGS published high accuracy positions. New positions were occupied near St. Marks National Wildlife Refuge and along the coastline of Levy County and Citrus County. Static surveys were conducted using four Ashtech dual frequency P-code receivers for 45-minute sessions and a data logging rate of 10 seconds. Network vector lengths ranged from 4 to 64 km and, including redundant baselines, totaled over 100 vectors. Analysis includes use of the GEOID93 model with a least squares network adjustment and reference to the National Geodetic Reference System (NGRS). The static surveys show high internal consistency and the desired centimeter-level accuracy is achieved for the local network. Uncertainties for the newly established vertical positions range from 0.8 cm to 1.8 cm at the 95% confidence level. These new positions provide sufficient vertical accuracy to achieve the project objectives of tying marsh surface elevations to long-term water level gauges recording sea level fluctuations along the coast.
NASA Technical Reports Server (NTRS)
Ketchum, Eleanor A. (Inventor)
2000-01-01
A computer-implemented method and apparatus for determining position of a vehicle within 100 km autonomously from magnetic field measurements and attitude data without a priori knowledge of position. An inverted dipole solution of two possible position solutions for each measurement of magnetic field data are deterministically calculated by a program controlled processor solving the inverted first order spherical harmonic representation of the geomagnetic field for two unit position vectors 180 degrees apart and a vehicle distance from the center of the earth. Correction schemes such as a successive substitutions and a Newton-Raphson method are applied to each dipole. The two position solutions for each measurement are saved separately. Velocity vectors for the position solutions are calculated so that a total energy difference for each of the two resultant position paths is computed. The position path with the smaller absolute total energy difference is chosen as the true position path of the vehicle.
Passive Multistatic Detection of Maritime Targets using Opportunistic Radars
2014-03-01
coordinate position for aa =1:1:length(Err_time1) Err_Total1( aa ) = max(abs(Err_time1( aa )),abs(Err_L1( aa ))+abs(Err_thetaR1( aa ))); end for aa =1...1:length(Err_time1) Err_Total1( aa ) = max(abs(Err_Total1( aa )),abs(Err_thetaR1( aa ))); end 93 %%%%%%%%%%%%%%%%%%%%% Tx 2...Err_Total2=zeros(size(Err_time2)); % Find th emax of the three source of error and use that for that % coordinate position for aa =1:1:length
Comparing the Performance of Indoor Localization Systems through the EvAAL Framework.
Potortì, Francesco; Park, Sangjoon; Jiménez Ruiz, Antonio Ramón; Barsocchi, Paolo; Girolami, Michele; Crivello, Antonino; Lee, So Yeon; Lim, Jae Hyun; Torres-Sospedra, Joaquín; Seco, Fernando; Montoliu, Raul; Mendoza-Silva, Germán Martin; Pérez Rubio, Maria Del Carmen; Losada-Gutiérrez, Cristina; Espinosa, Felipe; Macias-Guarasa, Javier
2017-10-13
In recent years, indoor localization systems have been the object of significant research activity and of growing interest for their great expected social impact and their impressive business potential. Application areas include tracking and navigation, activity monitoring, personalized advertising, Active and Assisted Living (AAL), traceability, Internet of Things (IoT) networks, and Home-land Security. In spite of the numerous research advances and the great industrial interest, no canned solutions have yet been defined. The diversity and heterogeneity of applications, scenarios, sensor and user requirements, make it difficult to create uniform solutions. From that diverse reality, a main problem is derived that consists in the lack of a consensus both in terms of the metrics and the procedures used to measure the performance of the different indoor localization and navigation proposals. This paper introduces the general lines of the EvAAL benchmarking framework, which is aimed at a fair comparison of indoor positioning systems through a challenging competition under complex, realistic conditions. To evaluate the framework capabilities, we show how it was used in the 2016 Indoor Positioning and Indoor Navigation (IPIN) Competition. The 2016 IPIN competition considered three different scenario dimensions, with a variety of use cases: (1) pedestrian versus robotic navigation, (2) smartphones versus custom hardware usage and (3) real-time positioning versus off-line post-processing. A total of four competition tracks were evaluated under the same EvAAL benchmark framework in order to validate its potential to become a standard for evaluating indoor localization solutions. The experience gained during the competition and feedback from track organizers and competitors showed that the EvAAL framework is flexible enough to successfully fit the very different tracks and appears adequate to compare indoor positioning systems.
Comparing the Performance of Indoor Localization Systems through the EvAAL Framework
2017-01-01
In recent years, indoor localization systems have been the object of significant research activity and of growing interest for their great expected social impact and their impressive business potential. Application areas include tracking and navigation, activity monitoring, personalized advertising, Active and Assisted Living (AAL), traceability, Internet of Things (IoT) networks, and Home-land Security. In spite of the numerous research advances and the great industrial interest, no canned solutions have yet been defined. The diversity and heterogeneity of applications, scenarios, sensor and user requirements, make it difficult to create uniform solutions. From that diverse reality, a main problem is derived that consists in the lack of a consensus both in terms of the metrics and the procedures used to measure the performance of the different indoor localization and navigation proposals. This paper introduces the general lines of the EvAAL benchmarking framework, which is aimed at a fair comparison of indoor positioning systems through a challenging competition under complex, realistic conditions. To evaluate the framework capabilities, we show how it was used in the 2016 Indoor Positioning and Indoor Navigation (IPIN) Competition. The 2016 IPIN competition considered three different scenario dimensions, with a variety of use cases: (1) pedestrian versus robotic navigation, (2) smartphones versus custom hardware usage and (3) real-time positioning versus off-line post-processing. A total of four competition tracks were evaluated under the same EvAAL benchmark framework in order to validate its potential to become a standard for evaluating indoor localization solutions. The experience gained during the competition and feedback from track organizers and competitors showed that the EvAAL framework is flexible enough to successfully fit the very different tracks and appears adequate to compare indoor positioning systems. PMID:29027948
Mobile-phone dispatch of laypersons for CPR in out-of-hospital cardiac arrest.
Ringh, Mattias; Rosenqvist, Mårten; Hollenberg, Jacob; Jonsson, Martin; Fredman, David; Nordberg, Per; Järnbert-Pettersson, Hans; Hasselqvist-Ax, Ingela; Riva, Gabriel; Svensson, Leif
2015-06-11
Cardiopulmonary resuscitation (CPR) performed by bystanders is associated with increased survival rates among persons with out-of-hospital cardiac arrest. We investigated whether rates of bystander-initiated CPR could be increased with the use of a mobile-phone positioning system that could instantly locate mobile-phone users and dispatch lay volunteers who were trained in CPR to a patient nearby with out-of-hospital cardiac arrest. We conducted a blinded, randomized, controlled trial in Stockholm from April 2012 through December 2013. A mobile-phone positioning system that was activated when ambulance, fire, and police services were dispatched was used to locate trained volunteers who were within 500 m of patients with out-of-hospital cardiac arrest; volunteers were then dispatched to the patients (the intervention group) or not dispatched to them (the control group). The primary outcome was bystander-initiated CPR before the arrival of ambulance, fire, and police services. A total of 5989 lay volunteers who were trained in CPR were recruited initially, and overall 9828 were recruited during the study. The mobile-phone positioning system was activated in 667 out-of-hospital cardiac arrests: 46% (306 patients) in the intervention group and 54% (361 patients) in the control group. The rate of bystander-initiated CPR was 62% (188 of 305 patients) in the intervention group and 48% (172 of 360 patients) in the control group (absolute difference for intervention vs. control, 14 percentage points; 95% confidence interval, 6 to 21; P<0.001). A mobile-phone positioning system to dispatch lay volunteers who were trained in CPR was associated with significantly increased rates of bystander-initiated CPR among persons with out-of-hospital cardiac arrest. (Funded by the Swedish Heart-Lung Foundation and Stockholm County; ClinicalTrials.gov number, NCT01789554.).
Zhao, Zhimiao; Song, Xinshan; Zhang, Yinjiang; Zhao, Yufeng; Wang, Bodi; Wang, Yuhui
2017-12-01
In the paper, we explored the influences of different dosages of iron and calcium carbonate on contaminant removal efficiencies and microbial communities in algal ponds combined with constructed wetlands. After 1-year operation of treatment systems, based on the high-throughput pyrosequencing analysis of microbial communities, the optimal operating conditions were obtained as follows: the ACW10 system with Fe 3+ (5.6 mg L -1 ), iron powder (2.8 mg L -1 ), and CaCO 3 powder (0.2 mg L -1 ) in influent as the adjusting agents, initial phosphorus source (PO 4 3- ) in influent, the ratio of nitrogen to phosphorus (N/P) of 30 in influent, and hydraulic retention time (HRT) of 1 day. Total nitrogen (TN) removal efficiency and total phosphorus (TP) removal efficiency were improved significantly. The hydrolysis of CaCO 3 promoted the physicochemical precipitation in contaminant removal. Meanwhile, Fe 3+ and iron powder produced Fe 2+ , which improved contaminant removal. Iron ion improved the diversity, distribution, and metabolic functions of microbial communities in integrated treatment systems. In the treatment ACW10, the dominant phylum in the microbial community was PLANCTOMYCETES, which positively promoted nitrogen removal. After 5 consecutive treatments in ACW10, contaminant removal efficiencies for TN and TP respectively reached 80.6% and 57.3% and total iron concentration in effluent was 0.042 mg L -1 . Copyright © 2017 Elsevier Ltd. All rights reserved.
Hu, Ting; He, Xiao-Wei; Jiang, Jian-Guo; Xu, Xi-Lin
2014-05-01
In order to evaluate the health effects of Ilex latifolia Thunb., a Chinese bitter tea widely consumed as a health beverage, flavonoids, saponins, polysaccharides and alkaloids were extracted from its leaves and their in vitro antioxidant activity, anticomplement system activity, antiproliferative effects against human cervical carcinoma Hela cells, and anti-inflammatory effects against mouse macrophage RAW 264.7 cells were analyzed. Results showed that the polysaccharides exhibited a considerable inhibition of the complement system, the hemolysis inhibition rate reached 98% at a concentration of 0.8 mg mL(-1), which was clearly higher than that of the positive control (heparin sodium). The total flavonoids displayed significant DPPH scavenging activity and an inhibition effect on the generation of NO in LPS-induced RAW 264.7 macrophages. In addition, the total saponins showed a better antiproliferative effect against Hela cells, and the total alkaloids exhibited a high reducing power. It is obvious that I. latifolia has a variety of nutritional and health functions which are attributed to its different components. The analysis method presented in this research can suggest lessons for analysis of other plant foods.
Yoshimatsu, Aya; Hoshi, Takuo; Nishikawa, Masashi; Aya, Daisuke; Ueda, Hiroshi; Yokouchi, Takako; Tanaka, Makoto
2013-08-01
We report a B Rh negative patient undergoing total pelvic exenteration, who received both ABO and Rh incompatible packed red blood cells in an emergency situation. After this experience, we revised the manual of emergency blood transfusion. We defined level of severity to share information with surgeon, nurses, anesthesiologists and the member of the blood center. We changed anesthesia information management system for showing blood type including Duffy blood group system and checking out whether we can transfuse Rh positive blood to Rh negative patient in an emergency situation at the timeout of surgery.
Design and implementation of a simple nuclear power plant simulator
NASA Astrophysics Data System (ADS)
Miller, William H.
1983-02-01
A simple PWR nuclear power plant simulator has been designed and implemented on a minicomputer system. The system is intended for students use in understanding the power operation of a nuclear power plant. A PDP-11 minicomputer calculates reactor parameters in real time, uses a graphics terminal to display the results and a keyboard and joystick for control functions. Plant parameters calculated by the model include the core reactivity (based upon control rod positions, soluble boron concentration and reactivity feedback effects), the total core power, the axial core power distribution, the temperature and pressure in the primary and secondary coolant loops, etc.
The prognostic significance of nonsentinel lymph node metastasis in melanoma.
Brown, Russell E; Ross, Merrick I; Edwards, Michael J; Noyes, R Dirk; Reintgen, Douglas S; Hagendoorn, Lee J; Stromberg, Arnold J; Martin, Robert C G; McMasters, Kelly M; Scoggins, Charles R
2010-12-01
We hypothesized that metastasis beyond the sentinel lymph nodes (SLN) to the nonsentinel nodes (NSN) is an important predictor of survival. Analysis was performed of a prospective multi-institutional study that included patients with melanoma ≥ 1.0 mm in Breslow thickness. All patients underwent SLN biopsy; completion lymphadenectomy was performed for all SLN metastases. Disease-free survival (DFS) and overall survival (OS) were computed by Kaplan-Meier analysis; univariate and multivariate analyses were performed to identify factors associated with differences in survival among groups. A total of 2335 patients were analyzed over a median follow-up of 68 months. We compared 3 groups: SLN negative (n = 1988), SLN-only positive (n = 296), and both SLN and NSN positive (n = 51). The 5-year DFS rates were 85.5, 64.8, and 42.6% for groups 1, 2, and 3, respectively (P < 0.001). The 5-year OS rates were 85.5, 64.9, and 49.4%, respectively (P < 0.001). On univariate analysis, predictors of decreased OS included: SLN metastasis, NSN metastasis, increased total number of positive LN, increased ratio of positive LN to total LN, increased age, male gender, increased Breslow thickness, presence of ulceration, Clark level ≥ IV, and axial primary site (in all cases, P < 0.01). When the total number of positive LN and NSN status were evaluated using multivariate analysis, NSN status remained statistically significant (P < 0.01), while the total number of positive LN and LN ratio did not. NSN melanoma metastasis is an independent prognostic factor for DFS and OS, which is distinct from the number of positive lymph nodes or the lymph node ratio.
NASA Astrophysics Data System (ADS)
Chen, Youhua; Cao, Ruizhi; Liu, Wenjie; Zhu, Dazhao; Zhang, Zhiming; Kuang, Cuifang; Liu, Xu
2018-04-01
We present an alternative approach to realize structured illumination microscopy (SIM), which is capable for live cell imaging. The prototype utilizes two sets of scanning galvo mirrors, a polarization converter and a piezo-platform to generate a fast shifted, s-polarization interfered and periodic variable illumination patterns. By changing the angle of the scanning galvanometer, we can change the position of the spots at the pupil plane of the objective lens arbitrarily, making it easy to switch between widefield and total internal reflection fluorescent-SIM mode and adapting the penetration depth in the sample. Also, a twofold resolution improvement is achieved in our experiments. The prototype offers more flexibility of pattern period and illumination orientation changing than previous systems.
Optimization of multimagnetometer systems on a spacecraft
NASA Technical Reports Server (NTRS)
Neubauer, F. M.
1975-01-01
The problem of optimizing the position of magnetometers along a boom of given length to yield a minimized total error is investigated. The discussion is limited to at most four magnetometers, which seems to be a practical limit due to weight, power, and financial considerations. The outlined error analysis is applied to some illustrative cases. The optimal magnetometer locations, for which the total error is minimum, are computed for given boom length, instrument errors, and very conservative magnetic field models characteristic for spacecraft with only a restricted or ineffective magnetic cleanliness program. It is shown that the error contribution by the magnetometer inaccuracy is increased as the number of magnetometers is increased, whereas the spacecraft field uncertainty is diminished by an appreciably larger amount.
Zhang, Xiaomeng; Inoue, Takashi; Kato, Kunihiko; Izumoto, Hayato; Harada, June; Wu, Da; Sakuragi, Hiroaki; Ietsugu, Hidehiro; Sugawara, Yasuhide
2017-01-01
This study followed three field-scale hybrid subsurface flow constructed wetland (CW) systems constructed in Hokkaido, northern Japan: piggery O (2009), dairy G (2011), and dairy S (2006). Treatment performance was monitored from the outset of operation for each CW. The ranges of overall purification efficiency for these systems were 70-86%, 40-85%, 71-90%, 91-96%, 94-98%, 84-97%, and 70-97% for total N (TN), NH 4 -N, total P, chemical oxygen demand (COD), biochemical oxygen demand, suspended solid, and total Coliform, respectively. The hybrid system's removal rates were highest when influent loads were high. COD removal rates were 46.4 ± 49.2, 94.1 ± 36.6, and 25.1 ± 15.5 g COD m -2 d -1 in piggery O, dairy G, and dairy S, with average influent loads of 50.5 ± 51.5, 98.9 ± 37.1, and 26.9 ± 16.0 g COD m -2 d -1 , respectively. The systems had overall COD removal efficiencies of around 90%. TN removal efficiencies were 62 ± 19%, 82 ± 9%, and 82 ± 15% in piggery O, dairy G, and dairy S, respectively. NH 4 -N removal efficiency was adversely affected by the COD/TN ratio. Results from this study prove that these treatment systems have sustained and positive pollutant removal efficiencies, which were achieved even under extremely cold climate conditions and many years after initial construction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses anmore » additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.« less
New approach to isometric transformations in oblique local coordinate systems of reference
NASA Astrophysics Data System (ADS)
Stępień, Grzegorz; Zalas, Ewa; Ziębka, Tomasz
2017-12-01
The research article describes a method of isometric transformation and determining an exterior orientation of a measurement instrument. The method is based on a designation of a "virtual" translation of two relative oblique orthogonal systems to a common, known in the both systems, point. The relative angle orientation of the systems does not change as each of the systems is moved along its axis. The next step is the designation of the three rotation angles (e.g. Tait-Bryan or Euler angles), transformation of the system convoluted at the calculated angles and moving the system to the initial position where the primary coordinate system was. This way eliminates movements of the systems from the calculations and makes it possible to calculate angles of mutual rotation angles of two orthogonal systems primarily involved in the movement. The research article covers laboratory calculations for simulated data. The accuracy of the results is 10-6 m (10-3 regarding the accuracy of the input data). This confi rmed the correctness of the assumed calculation method. In the following step the method was verifi ed under fi eld conditions, where the accuracy of the method raised to 0.003 m. The proposed method enabled to make the measurements with the oblique and uncentered instrument, e.g. total station instrument set over an unknown point. This is the reason why the method was named by the authors as Total Free Station - TFS. The method may be also used for isometric transformations for photogrammetric purposes.
St George, K; Boyd, M J; Lipson, S M; Ferguson, D; Cartmell, G F; Falk, L H; Rinaldo, C R; Landry, M L
2000-04-01
A total of 513 blood specimens, predominantly from organ transplant recipients, human immunodeficiency virus-positive patients, and bone marrow transplant recipients, were tested for cytomegalovirus (CMV) by culture and pp65 antigenemia across four test sites. Peripheral blood leukocytes were examined by using both the Biotest CMV Brite and the Bartels/Argene CMV Antigenemia kits. A total of 109 specimens were positive for CMV, 106 (97%) were positive by antigenemia, and 34 (31%) were positive by culture. According to the manufacturers' instructions, 150,000 cells were applied per slide for the Biotest kit and 200,000 cells per slide for the Bartels kit. A total of 93 specimens (88%) were positive by the Biotest kit, and 86 (81%) were positive by the Bartels kit. In specimens found to be positive by only one kit, the positive cell counts were low (median, 1; range, 1 to 7). When the data from all four sites were combined and analyzed, there was no statistical difference between the performance of the two kits; the Biotest and Bartels kits were found to be equivalent in sensitivity, specificity, and positive and negative predictive values for the detection of CMV pp65 antigenemia.
Integrated cockpit design for the Army helicopter improvement program
NASA Technical Reports Server (NTRS)
Drennen, T.; Bowen, B.
1984-01-01
The main Army Helicopter Improvement Program (AHIP) mission is to navigate precisely, locate targets accurately, communicate their position to other battlefield elements, and to designate them for laser guided weapons. The onboard navigation and mast-mounted sight (MMS) avionics enable accurate tracking of current aircraft position and subsequent target location. The AHIP crewstation development was based on extensive mission/task analysis, function allocation, total system design, and test and verification. The avionics requirements to meet the mission was limited by the existing aircraft structural and performance characteristics and resultant space, weight, and power restrictions. These limitations and night operations requirement led to the use of night vision goggles. The combination of these requirements and limitations dictated an integrated control/display approach using multifunction displays and controls.
Marzocchi, O; Breustedt, B; Mostacci, D; Zankl, M; Urban, M
2011-03-01
A goal of whole body counting (WBC) is the estimation of the total body burden of radionuclides disregarding the actual position within the body. To achieve the goal, the detectors need to be placed in regions where the photon flux is as independent as possible from the distribution of the source. At the same time, the detectors need high photon fluxes in order to achieve better efficiency and lower minimum detectable activities. This work presents a method able to define the layout of new WBC systems and to study the behaviour of existing ones using both detection efficiency and its dependence on the position of the source within the body of computational phantoms.
NASA Technical Reports Server (NTRS)
Budinoff, Jason; Gendreau, Keith; Arzoumanian, Zaven; Baker, Charles; Berning, Robert; Colangelo, Todd; Holzinger, John; Lewis, Jesse; Liu, Alice; Mitchell, Alissa;
2015-01-01
This paper describes the design of a unique suite of mechanisms which make up the Deployment and Pointing System (DAPS) for the Neutron Star Interior Composition Explorer (NICER/SEXTANT) instrument, an X-Ray telescope, which will be mounted on the International Space Station (ISS). The DAPS system uses 4 stepper motor actuators to deploy the telescope box, latch it in the deployed position, and allow it to track sky targets. The DAPS gimbal architecture provides full-hemisphere coverage, and is fully re-stowable. The compact design of the mechanism allowed the majority of total instrument volume to be used for science. Override features allow DAPS to be stowed by ISS robotics.
NASA Technical Reports Server (NTRS)
Budinoff, Jason; Gendreau, Keith; Arzoumanian, Zaven; Baker, Charles; Berning, Robert; Colangelo, TOdd; Holzinger, John; Lewis, Jesse; Liu, Alice; Mitchell, Alissa;
2016-01-01
This paper describes the design of a unique suite of mechanisms that make up the Deployment and Pointing System (DAPS) for the Neutron Star Interior Composition Explorer (NICER/SEXTANT) instrument, an X-Ray telescope, which will be mounted on the International Space Station (ISS). The DAPS system uses four stepper motor actuators to deploy the telescope box, latch it in the deployed position, and allow it to track sky targets. The DAPS gimbal architecture provides full-hemisphere coverage, and is fully re-stowable. The compact design of the mechanism allowed the majority of total instrument volume to be used for science. Override features allow DAPS to be stowed by ISS robotics.
Zimmermann, Frauke; Schwenninger, Christoph; Nolten, Ulrich; Firmbach, Franz Peter; Elfring, Robert; Radermacher, Klaus
2012-05-06
Preservation and recovery of the mechanical leg axis as well as good rotational alignment of the prosthesis components and well-balanced ligaments are essential for the longevity of total knee arthroplasty (TKA). In the framework of the OrthoMIT project, the genALIGN system, a new navigated implantation approach based on intra-operative force-torque measurements, has been developed. With this system, optical or magnetic position tracking as well as any fixation of invasive rigid bodies are no longer necessary. For the alignment of the femoral component along the mechanical axis, a sensor-integrated instrument measures the torques resulting from the deviation between the instrument's axis and the mechanical axis under manually applied axial compression load. When both axes are coaxial, the resulting torques equal zero, and the tool axis can be fixed with respect to the bone. For ligament balancing and rotational alignment of the femoral component, the genALIGN system comprises a sensor-integrated tibial trial inlay measuring the amplitude and application points of the forces transferred between femur and tibia. Hereby, the impact of ligament tensions on knee joint loads can be determined over the whole range of motion. First studies with the genALIGN system, including a comparison with an imageless navigation system, show the feasibility of the concept.