Sample records for positive false negative

  1. Memory for media: investigation of false memories for negatively and positively charged public events.

    PubMed

    Porter, Stephen; Taylor, Kristian; Ten Brinke, Leanne

    2008-01-01

    Despite a large body of false memory research, little has addressed the potential influence of an event's emotional content on susceptibility to false recollections. The Paradoxical Negative Emotion (PNE) hypothesis predicts that negative emotion generally facilitates memory but also heightens susceptibility to false memories. Participants were asked whether they could recall 20 "widely publicised" public events (half fictitious) ranging in emotional valence, with or without visual cues. Participants recalled a greater number of true negative events (M=3.31/5) than true positive (M=2.61/5) events. Nearly everyone (95%) came to recall at least one false event (M=2.15 false events recalled). Further, more than twice as many participants recalled any false negative (90%) compared to false positive (41.7%) events. Negative events, in general, were associated with more detailed memories and false negative event memories were more detailed than false positive event memories. Higher dissociation scores were associated with false recollections of negative events, specifically.

  2. A Closer Look at Self-Reported Suicide Attempts: False Positives and False Negatives

    ERIC Educational Resources Information Center

    Ploderl, Martin; Kralovec, Karl; Yazdi, Kurosch; Fartacek, Reinhold

    2011-01-01

    The validity of self-reported suicide attempt information is undermined by false positives (e.g., incidences without intent to die), or by unreported suicide attempts, referred to as false negatives. In a sample of 1,385 Austrian adults, we explored the occurrence of false positives and false negatives with detailed, probing questions. Removing…

  3. "False Positive" Claims of Near-Death Experiences and "False Negative" Denials of Near-Death Experiences

    ERIC Educational Resources Information Center

    Greyson, Bruce

    2005-01-01

    Some persons who claim to have had near-death experiences (NDEs) fail research criteria for having had NDEs ("false positives"); others who deny having had NDEs do meet research criteria for having had NDEs ("false negatives"). The author evaluated false positive claims and false negative denials in an organization that promotes near-death…

  4. False negative rates in Drosophila cell-based RNAi screens: a case study

    PubMed Central

    2011-01-01

    Background High-throughput screening using RNAi is a powerful gene discovery method but is often complicated by false positive and false negative results. Whereas false positive results associated with RNAi reagents has been a matter of extensive study, the issue of false negatives has received less attention. Results We performed a meta-analysis of several genome-wide, cell-based Drosophila RNAi screens, together with a more focused RNAi screen, and conclude that the rate of false negative results is at least 8%. Further, we demonstrate how knowledge of the cell transcriptome can be used to resolve ambiguous results and how the number of false negative results can be reduced by using multiple, independently-tested RNAi reagents per gene. Conclusions RNAi reagents that target the same gene do not always yield consistent results due to false positives and weak or ineffective reagents. False positive results can be partially minimized by filtering with transcriptome data. RNAi libraries with multiple reagents per gene also reduce false positive and false negative outcomes when inconsistent results are disambiguated carefully. PMID:21251254

  5. Occupancy models for data with false positive and false negative errors and heterogeneity across sites and surveys

    Treesearch

    Paige F.B. Ferguson; Michael J. Conroy; Jeffrey Hepinstall-Cymerman; Nigel Yoccoz

    2015-01-01

    False positive detections, such as species misidentifications, occur in ecological data, although many models do not account for them. Consequently, these models are expected to generate biased inference.The main challenge in an analysis of data with false positives is to distinguish false positive and false negative...

  6. Comparison of 4th-Generation HIV Antigen/Antibody Combination Assay With 3rd-Generation HIV Antibody Assays for the Occurrence of False-Positive and False-Negative Results.

    PubMed

    Muthukumar, Alagarraju; Alatoom, Adnan; Burns, Susan; Ashmore, Jerry; Kim, Anne; Emerson, Brian; Bannister, Edward; Ansari, M Qasim

    2015-01-01

    To assess the false-positive and false-negative rates of a 4th-generation human immunodeficiency virus (HIV) assay, the Abbott ARCHITECT, vs 2 HIV 3rd-generation assays, the Siemens Centaur and the Ortho-Clinical Diagnostics Vitros. We examined 123 patient specimens. In the first phase of the study, we compared 99 specimens that had a positive screening result via the 3rd-generation Vitros assay (10 positive, 82 negative, and 7 indeterminate via confirmatory immunofluorescent assay [IFA]/Western blot [WB] testing). In the second phase, we assessed 24 HIV-1 RNA-positive (positive result via the nuclear acid amplification test [NAAT] and negative/indeterminate results via the WB test) specimens harboring acute HIV infection. The 4th-generation ARCHITECT assay yielded fewer false-positive results (n = 2) than the 3rd-generation Centaur (n = 9; P = .02) and Vitros (n = 82; P <.001) assays. One confirmed positive case had a false-negative result via the Centaur assay. When specimens from the 24 patients with acute HIV-1 infection were tested, the ARCHITECT assay yielded fewer false-negative results (n = 5) than the Centaur (n = 10) (P = .13) and the other 3rd-generation tests (n = 16) (P = .002). This study indicates that the 4th-generation ARCHITECT HIV assay yields fewer false-positive and false-negative results than the 3rd-generation HIV assays we tested. Copyright© by the American Society for Clinical Pathology (ASCP).

  7. Working memory affects false memory production for emotional events.

    PubMed

    Mirandola, Chiara; Toffalini, Enrico; Ciriello, Alfonso; Cornoldi, Cesare

    2017-01-01

    Whereas a link between working memory (WM) and memory distortions has been demonstrated, its influence on emotional false memories is unclear. In two experiments, a verbal WM task and a false memory paradigm for negative, positive or neutral events were employed. In Experiment 1, we investigated individual differences in verbal WM and found that the interaction between valence and WM predicted false recognition, with negative and positive material protecting high WM individuals against false remembering; the beneficial effect of negative material disappeared in low WM participants. In Experiment 2, we lowered the WM capacity of half of the participants with a double task request, which led to an overall increase in false memories; furthermore, consistent with Experiment 1, the increase in negative false memories was larger than that of neutral or positive ones. It is concluded that WM plays a critical role in determining false memory production, specifically influencing the processing of negative material.

  8. Analysis of false results in a series of 835 fine needle aspirates of breast lesions.

    PubMed

    Willis, S L; Ramzy, I

    1995-01-01

    To analyze cases of false diagnoses from a large series to help increase the accuracy of fine needle aspiration of palpable breast lesions. The results of FNA of 835 palpable breast lesions were analyzed to determine the reasons for false positive, false negative and false suspicious diagnoses. Of the 835 aspirates, 174 were reported as positive, 549 as negative and 66 as suspicious or atypical but not diagnostic of malignancy. Forty-six cases were considered unsatisfactory. Tissue was available for comparison in 286 cases. The cytologic diagnoses in these cases were reported as follows: positive, 125 (43.7%); suspicious, 33 (11.5%); atypical, 18 (6.2%); negative, 92 (32%); and unsatisfactory, 18 (6.2%). There was one false positive diagnosis, yielding a false positive rate of 0.8%. This lesion was a case of fibrocystic change with hyperplasia, focal fat necrosis and reparative atypia. There were 14 false negative cases, resulting in a false negative rate of 13.2%. Nearly all these cases were sampling errors and included infiltrating ductal carcinomas (9), ductal carcinomas in situ (2), infiltrating lobular carcinomas (2) and tubular carcinoma (1). Most of the suspicious and atypical lesions proved to be carcinomas (35/50). The remainder were fibroadenomas (6), fibrocystic change (4), gynecomastia (2), adenosis (2) and granulomatous mastitis (1). A positive diagnosis of malignancy by FNA is reliable in establishing the diagnosis and planning the treatment of breast cancer. The false-positive rate is very low, with only a single case reported in 835 aspirates. Most false negatives are due to sampling and not to interpretive difficulties. The category "suspicious but not diagnostic of malignancy" serves a useful purpose in management of patients with breast lumps.

  9. [Roaming through methodology. XXXII. False test results].

    PubMed

    van der Weijden, T; van den Akker, M

    2001-05-12

    The number of requests for diagnostic tests is rising. This leads to a higher chance of false test results. The false-negative proportion of a test is the proportion of negative test results among the diseased subjects. The false-positive proportion is the proportion of positive test results among the healthy subjects. The calculation of the false-positive proportion is often incorrect. For example, instead of 1 minus the specificity it is calculated as 1 minus the positive predictive value. This can lead to incorrect decision-making with respect to the application of the test. Physicians must apply diagnostic tests in such a way that the risk of false test results is minimal. The patient should be aware that a perfectly conclusive diagnostic test is rare in medical practice, and should more often be informed of the implications of false-positive and false-negative test results.

  10. Negative affect promotes encoding of and memory for details at the expense of the gist: affect, encoding, and false memories.

    PubMed

    Storbeck, Justin

    2013-01-01

    I investigated whether negative affective states enhance encoding of and memory for item-specific information reducing false memories. Positive, negative, and neutral moods were induced, and participants then completed a Deese-Roediger-McDermott (DRM) false-memory task. List items were presented in unique spatial locations or unique fonts to serve as measures for item-specific encoding. The negative mood conditions had more accurate memories for item-specific information, and they also had fewer false memories. The final experiment used a manipulation that drew attention to distinctive information, which aided learning for DRM words, but also promoted item-specific encoding. For the condition that promoted item-specific encoding, false memories were reduced for positive and neutral mood conditions to a rate similar to that of the negative mood condition. These experiments demonstrated that negative affective cues promote item-specific processing reducing false memories. People in positive and negative moods encode events differently creating different memories for the same event.

  11. Bladder cancer diagnosis with CT urography: test characteristics and reasons for false-positive and false-negative results.

    PubMed

    Trinh, Tony W; Glazer, Daniel I; Sadow, Cheryl A; Sahni, V Anik; Geller, Nina L; Silverman, Stuart G

    2018-03-01

    To determine test characteristics of CT urography for detecting bladder cancer in patients with hematuria and those undergoing surveillance, and to analyze reasons for false-positive and false-negative results. A HIPAA-compliant, IRB-approved retrospective review of reports from 1623 CT urograms between 10/2010 and 12/31/2013 was performed. 710 examinations for hematuria or bladder cancer history were compared to cystoscopy performed within 6 months. Reference standard was surgical pathology or 1-year minimum clinical follow-up. False-positive and false-negative examinations were reviewed to determine reasons for errors. Ninety-five bladder cancers were detected. CT urography accuracy: was 91.5% (650/710), sensitivity 86.3% (82/95), specificity 92.4% (568/615), positive predictive value 63.6% (82/129), and negative predictive value was 97.8% (568/581). Of 43 false positives, the majority of interpretation errors were due to benign prostatic hyperplasia (n = 12), trabeculated bladder (n = 9), and treatment changes (n = 8). Other causes include blood clots, mistaken normal anatomy, infectious/inflammatory changes, or had no cystoscopic correlate. Of 13 false negatives, 11 were due to technique, one to a large urinary residual, one to artifact. There were no errors in perception. CT urography is an accurate test for diagnosing bladder cancer; however, in protocols relying predominantly on excretory phase images, overall sensitivity remains insufficient to obviate cystoscopy. Awareness of bladder cancer mimics may reduce false-positive results. Improvements in CTU technique may reduce false-negative results.

  12. The problem of false positives and false negatives in violent video game experiments.

    PubMed

    Ferguson, Christopher J

    The problem of false positives and negatives has received considerable attention in behavioral research in recent years. The current paper uses video game violence research as an example of how such issues may develop in a field. Despite decades of research, evidence on whether violent video games (VVGs) contribute to aggression in players has remained mixed. Concerns have been raised in recent years that experiments regarding VVGs may suffer from both "false positives" and "false negatives." The current paper examines this issue in three sets of video game experiments, two sets of video game experiments on aggression and prosocial behaviors identified in meta-analysis, and a third group of recent null studies. Results indicated that studies of VVGs and aggression appear to be particularly prone to false positive results. Studies of VVGs and prosocial behavior, by contrast are heterogeneous and did not demonstrate any indication of false positive results. However, their heterogeneous nature made it difficult to base solid conclusions on them. By contrast, evidence for false negatives in null studies was limited, and little evidence emerged that null studies lacked power in comparison those highlighted in past meta-analyses as evidence for effects. These results are considered in light of issues related to false positives and negatives in behavioral science more broadly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Which Factors Contribute to False-Positive, False-Negative, and Invalid Results in Fetal Fibronectin Testing in Women with Symptoms of Preterm Labor?

    PubMed

    Bruijn, Merel M C; Hermans, Frederik J R; Vis, Jolande Y; Wilms, Femke F; Oudijk, Martijn A; Kwee, Anneke; Porath, Martina M; Oei, Guid; Scheepers, Hubertina C J; Spaanderman, Marc E A; Bloemenkamp, Kitty W M; Haak, Monique C; Bolte, Antoinette C; Vandenbussche, Frank P H A; Woiski, Mallory D; Bax, Caroline J; Cornette, Jérôme M J; Duvekot, Johannes J; Bijvank, Bas W A N I J; van Eyck, Jim; Franssen, Maureen T M; Sollie, Krystyna M; van der Post, Joris A M; Bossuyt, Patrick M M; Kok, Marjolein; Mol, Ben W J; van Baaren, Gert-Jan

    2017-02-01

    Objective  We assessed the influence of external factors on false-positive, false-negative, and invalid fibronectin results in the prediction of spontaneous delivery within 7 days. Methods  We studied symptomatic women between 24 and 34 weeks' gestational age. We performed uni- and multivariable logistic regression to estimate the effect of external factors (vaginal soap, digital examination, transvaginal sonography, sexual intercourse, vaginal bleeding) on the risk of false-positive, false-negative, and invalid results, using spontaneous delivery within 7 days as the outcome. Results  Out of 708 women, 237 (33%) had a false-positive result; none of the factors showed a significant association. Vaginal bleeding increased the proportion of positive fetal fibronectin (fFN) results, but was significantly associated with a lower risk of false-positive test results (odds ratio [OR], 0.22; 95% confidence intervals [CI], 0.12-0.39). Ten women (1%) had a false-negative result. None of the investigated factors was significantly associated with a significantly higher risk of false-negative results. Twenty-one tests (3%) were invalid; only vaginal bleeding showed a significant association (OR, 4.5; 95% CI, 1.7-12). Conclusion  The effect of external factors on the performance of qualitative fFN testing is limited, with vaginal bleeding as the only factor that reduces its validity. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Generalized site occupancy models allowing for false positive and false negative errors

    USGS Publications Warehouse

    Royle, J. Andrew; Link, W.A.

    2006-01-01

    Site occupancy models have been developed that allow for imperfect species detection or ?false negative? observations. Such models have become widely adopted in surveys of many taxa. The most fundamental assumption underlying these models is that ?false positive? errors are not possible. That is, one cannot detect a species where it does not occur. However, such errors are possible in many sampling situations for a number of reasons, and even low false positive error rates can induce extreme bias in estimates of site occupancy when they are not accounted for. In this paper, we develop a model for site occupancy that allows for both false negative and false positive error rates. This model can be represented as a two-component finite mixture model and can be easily fitted using freely available software. We provide an analysis of avian survey data using the proposed model and present results of a brief simulation study evaluating the performance of the maximum-likelihood estimator and the naive estimator in the presence of false positive errors.

  15. Discordant HIV Test Results: Implications on Perinatal and Haemotransfusion Screening for HIV Infection, Cape Coast, Ghana.

    PubMed

    Tetteh, Ato Kwamena; Agyarko, Edward

    2017-01-01

    Screening results of 488 pregnant women aged 15-44 years whose blood samples had been tested on-site, using First Response® HIV 1/2, and confirmed with INNO-LIA™ HIV I/II Score were used. Of this total, 178 were reactive (HIV I, 154; HIV II, 2; and HIV I and HIV II, 22). Of the 154 HIV I-reactive samples, 104 were confirmed to be HIV I-positive and 2 were confirmed to be HIV II-positive, while 48 were confirmed to be negative [false positive rate = 17.44% (13.56-21.32)]. The two HIV II samples submitted were confirmed to be negative with the confirmatory test. For the 22 HIV I and HIV II samples, 7 were confirmed to be HIV I-positive and 1 was confirmed to be HIV I- and HIV II-positive, while 14 were confirmed to be negative. Of the 310 nonreactive samples, 6 were confirmed to be HIV I-positive and 1 was confirmed to be HIV II-positive [false negative rate = 5.79% (1.63-8.38)], while 303 were negative. False negative outcomes will remain unconfirmed, with no management options for the client. False negative rate of 5.79% requires attention, as its resultant implications on control of HIV/AIDS could be dire.

  16. Sherlock Holmes and child psychopathology assessment approaches: the case of the false-positive.

    PubMed

    Jensen, P S; Watanabe, H

    1999-02-01

    To explore the relative value of various methods of assessing childhood psychopathology, the authors compared 4 groups of children: those who met criteria for one or more DSM diagnoses and scored high on parent symptom checklists, those who met psychopathology criteria on either one of these two assessment approaches alone, and those who met no psychopathology assessment criterion. Parents of 201 children completed the Child Behavior Checklist (CBCL), after which children and parents were administered the Diagnostic Interview Schedule for Children (version 2.1). Children and parents also completed other survey measures and symptom report inventories. The 4 groups of children were compared against "external validators" to examine the merits of "false-positive" and "false-negative" cases. True-positive cases (those that met DSM criteria and scored high on the CBCL) differed significantly from the true-negative cases on most external validators. "False-positive" and "false-negative" cases had intermediate levels of most risk factors and external validators. "False-positive" cases were not normal per se because they scored significantly above the true-negative group on a number of risk factors and external validators. A similar but less marked pattern was noted for "false-negatives." Findings call into question whether cases with high symptom checklist scores despite no formal diagnoses should be considered "false-positive." Pending the availability of robust markers for mental illness, researchers and clinicians must resist the tendency to reify diagnostic categories or to engage in arcane debates about the superiority of one assessment approach over another.

  17. Shear-wave elastography in the diagnosis of solid breast masses: what leads to false-negative or false-positive results?

    PubMed

    Yoon, Jung Hyun; Jung, Hae Kyoung; Lee, Jong Tae; Ko, Kyung Hee

    2013-09-01

    To investigate the factors that have an effect on false-positive or false-negative shear-wave elastography (SWE) results in solid breast masses. From June to December 2012, 222 breast lesions of 199 consecutive women (mean age: 45.3 ± 10.1 years; range, 21 to 88 years) who had been scheduled for biopsy or surgical excision were included. Greyscale ultrasound and SWE were performed in all women before biopsy. Final ultrasound assessments and SWE parameters (pattern classification and maximum elasticity) were recorded and compared with histopathology results. Patient and lesion factors in the 'true' and 'false' groups were compared. Of the 222 masses, 175 (78.8 %) were benign, and 47 (21.2 %) were malignant. False-positive rates of benign masses were significantly higher than false-negative rates of malignancy in SWE patterns, 36.6 % to 6.4 % (P < 0.001). Among both benign and malignant masses, factors showing significance among false SWE features were lesion size, breast thickness and lesion depth (all P < 0.05). All 47 malignant breast masses had SWE images of good quality. False SWE features were more significantly seen in benign masses. Lesion size, breast thickness and lesion depth have significance in producing false results, and this needs consideration in SWE image acquisition. • Shear-wave elastography (SWE) is widely used during breast imaging • At SWE, false-positive rates were significantly higher than false-negative rates • Larger size, breast thickness, depth and fair quality influences false-positive SWE features • Smaller size, larger breast thickness and depth influences false-negative SWE features.

  18. Effects of depressive disorder on false memory for emotional information.

    PubMed

    Yeh, Zai-Ting; Hua, Mau-Sun

    2009-01-01

    This study explored with a false memory paradigm whether (1) depressed patients revealed more false memories and (2) whether more negative false than positive false recognition existed in subjects with depressive disorders. Thirty-two patients suffering from a major depressive episode (DSM-IV criteria), and 30 age- and education-matched normal control subjects participated in this study. After the presentation of a list of positive, negative, and neutral association items in the learning phase, subjects were asked to give a yes/no response in the recognition phase. They were also asked to rate 81 recognition items with emotional valence scores. The results revealed more negative false memories in the clinical depression group than in the normal control group; however, we did not find more negative false memories than positive ones in patients. When compared with the normal group, a more conservative response criterion for positive items was evident in patient groups. It was also found that when compared with the normal group, the subjects in the depression group perceived the positive items as less positive. On the basis of present results, it is suggested that depressed subjects judged the emotional information with criteria different from normal individuals, and patients' emotional memory intensity is attenuated by their mood.

  19. False-negative rapid diagnostic tests for malaria and deletion of the histidine-rich repeat region of the hrp2 gene.

    PubMed

    Koita, Ousmane A; Doumbo, Ogobara K; Ouattara, Amed; Tall, Lalla K; Konaré, Aoua; Diakité, Mahamadou; Diallo, Mouctar; Sagara, Issaka; Masinde, Godfred L; Doumbo, Safiatou N; Dolo, Amagana; Tounkara, Anatole; Traoré, Issa; Krogstad, Donald J

    2012-02-01

    We identified 480 persons with positive thick smears for asexual Plasmodium falciparum parasites, of whom 454 had positive rapid diagnostic tests (RDTs) for the histidine-rich protein 2 (HRP2) product of the hrp2 gene and 26 had negative tests. Polymerase chain reaction (PCR) amplification for the histidine-rich repeat region of that gene was negative in one-half (10/22) of false-negative specimens available, consistent with spontaneous deletion. False-negative RDTs were found only in persons with asymptomatic infections, and multiplicities of infection (MOIs) were lower in persons with false-negative RDTs (both P < 0.001). These results show that parasites that fail to produce HRP2 can cause patent bloodstream infections and false-negative RDT results. The importance of these observations is likely to increase as malaria control improves, because lower MOIs are associated with false-negative RDTs and false-negative RDTs are more frequent in persons with asymptomatic infections. These findings suggest that the use of HRP2-based RDTs should be reconsidered.

  20. How does negative emotion cause false memories?

    PubMed

    Brainerd, C J; Stein, L M; Silveira, R A; Rohenkohl, G; Reyna, V F

    2008-09-01

    Remembering negative events can stimulate high levels of false memory, relative to remembering neutral events. In experiments in which the emotional valence of encoded materials was manipulated with their arousal levels controlled, valence produced a continuum of memory falsification. Falsification was highest for negative materials, intermediate for neutral materials, and lowest for positive materials. Conjoint-recognition analysis produced a simple process-level explanation: As one progresses from positive to neutral to negative valence, false memory increases because (a) the perceived meaning resemblance between false and true items increases and (b) subjects are less able to use verbatim memories of true items to suppress errors.

  1. True detection limits in an experimental linearly heteroscedastic system.. Part 2

    NASA Astrophysics Data System (ADS)

    Voigtman, Edward; Abraham, Kevin T.

    2011-11-01

    Despite much different processing of the experimental fluorescence detection data presented in Part 1, essentially the same estimates were obtained for the true theoretical Currie decision levels ( YC and XC) and true Currie detection limits ( YD and XD). The obtained experimental values, for 5% probability of false positives and 5% probability of false negatives, were YC = 56.0 mV, YD = 125. mV, XC = 0.132 μg/mL and XD = 0.293 μg/mL. For 5% probability of false positives and 1% probability of false negatives, the obtained detection limits were YD = 158 . mV and XD = 0.371 μg/mL. Furthermore, by using bootstrapping methodology on the experimental data for the standards and the analytical blank, it was possible to validate previously published experimental domain expressions for the decision levels ( yC and xC) and detection limits ( yD and xD). This was demonstrated by testing the generated decision levels and detection limits for their performance in regard to false positives and false negatives. In every case, the obtained numbers of false negatives and false positives were as specified a priori.

  2. Misdiagnosis of HIV infection during a South African community-based survey: implications for rapid HIV testing

    PubMed Central

    Kufa, Tendesayi; Kharsany, Ayesha BM; Cawood, Cherie; Khanyile, David; Lewis, Lara; Grobler, Anneke; Chipeta, Zawadi; Bere, Alfred; Glenshaw, Mary; Puren, Adrian

    2017-01-01

    Abstract Introduction: We describe the overall accuracy and performance of a serial rapid HIV testing algorithm used in community-based HIV testing in the context of a population-based household survey conducted in two sub-districts of uMgungundlovu district, KwaZulu-Natal, South Africa, against reference fourth-generation HIV-1/2 antibody and p24 antigen combination immunoassays. We discuss implications of the findings on rapid HIV testing programmes. Methods: Cross-sectional design: Following enrolment into the survey, questionnaires were administered to eligible and consenting participants in order to obtain demographic and HIV-related data. Peripheral blood samples were collected for HIV-related testing. Participants were offered community-based HIV testing in the home by trained field workers using a serial algorithm with two rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using two fourth-generation immunoassays with all positives in the confirmatory test considered true positives. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value and false-positive and false-negative rates were determined. Results: Of 10,236 individuals enrolled in the survey, 3740 were tested in the home (median age 24 years (interquartile range 19–31 years), 42.1% males and HIV positivity on RDT algorithm 8.0%). From those tested, 3729 (99.7%) had a definitive RDT result as well as a laboratory immunoassay result. The overall accuracy of the RDT when compared to the fourth-generation immunoassays was 98.8% (95% confidence interval (CI) 98.5–99.2). The sensitivity, specificity, positive predictive value and negative predictive value were 91.1% (95% CI 87.5–93.7), 99.9% (95% CI 99.8–100), 99.3% (95% CI 97.4–99.8) and 99.1% (95% CI 98.8–99.4) respectively. The false-positive and false-negative rates were 0.06% (95% CI 0.01–0.24) and 8.9% (95% CI 6.3–12.53). Compared to true positives, false negatives were more likely to be recently infected on limited antigen avidity assay and to report antiretroviral therapy (ART) use. Conclusions: The overall accuracy of the RDT algorithm was high. However, there were few false positives, and the sensitivity was lower than expected with high false negatives, despite implementation of quality assurance measures. False negatives were associated with recent (early) infection and ART exposure. The RDT algorithm was able to correctly identify the majority of HIV infections in community-based HIV testing. Messaging on the potential for false positives and false negatives should be included in these programmes. PMID:28872274

  3. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    PubMed

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2018-06-01

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P < .05). The diagnostic accuracy was best in nodules of 5 to 10 mm in diameter. The sensitivity, accuracy, PPV, and LR for negative US-guided FNA results were better in nodules with a size range of 5 to 15 mm. The specificity, negative predictive value (NPV), and LR for positive results and the Youden index rose with increasing nodule size. Seventeen false-positive and 60 false-negative results were found in this study. The false-negative rate rose with increasing nodule size. However, the false-positive rate was highest in the group containing the smallest nodules. Nodules with circumscribed margins and those that were nonsolid and nonhypoechoic and had no microcalcifications correlated with Bethesda I FNA results. Nodules with circumscribed margins and those that were nonsolid, heterogeneous, and nonhypoechoic and had increased vascularity correlated with false-negative FNA results. Borders correlated with Bethesda I false-negative and false-positive FNA results. Tiny nodules (≤5 mm) with obscure borders tended to yield false-positive FNA results. Large nodules (>20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  4. False-Positive Xpert MTB/RIF Results in Retested Patients with Previous Tuberculosis: Frequency, Profile, and Prospective Clinical Outcomes.

    PubMed

    Theron, Grant; Venter, Rouxjeane; Smith, Liezel; Esmail, Aliasgar; Randall, Philippa; Sood, Vishesh; Oelfese, Suzette; Calligaro, Greg; Warren, Robin; Dheda, Keertan

    2018-03-01

    Globally, Xpert MTB/RIF (Xpert) is the most widely used PCR test for the diagnosis of tuberculosis (TB). Positive results in previously treated patients, which are due to old DNA or active disease, are a diagnostic dilemma. We prospectively retested sputum from 238 patients, irrespective of current symptoms, who were previously diagnosed to be Xpert positive and treated successfully. Patients who retested as Xpert positive and culture negative were exhaustively investigated (repeat culture, chest radiography, bronchoscopy with bronchoalveolar lavage, long-term clinical follow-up). We evaluated whether the duration since previous treatment completion, mycobacterial burden (the Xpert cycle threshold [ C T ] value), and reclassification of Xpert-positive results with a very low semiquantitation level to Xpert-negative results reduced the rate of false positivity. A total of 229/238 (96%) of patients were culture negative. Sixteen of 229 (7%) were Xpert positive a median of 11 months (interquartile range, 5 to 19 months) after treatment completion. The specificity was 93% (95% confidence interval [CI], 89 to 96%). Nine of 15 (40%) Xpert-positive, culture-negative patients reverted to Xpert negative after 2 to 3 months (1 patient declined further participation). Patients with false-positive Xpert results had a lower mycobacterial burden than patients with true-positive Xpert results ( C T , 28.7 [95% CI, 27.2 to 30.4] versus 17.6 [95% CI, 16.9 to 18.2]; P < 0.001), an increased likelihood of a chest radiograph not compatible with active TB (5/15 patients versus 0/5 patients; P = 0.026), and less-viscous sputum (15/16 patients versus 2/5 patients whose sputum was graded as mucoid or less; P = 0.038). All patients who initially retested as Xpert positive and culture negative ("Xpert false positive") were clinically well without treatment after follow-up. The duration since the previous treatment poorly predicted false-positive results (a duration of ≤2 years identified only 66% of patients with false-positive results). Reclassifying Xpert-positive results with a very low semiquantitation level to Xpert negative improved the specificity (+3% [95% CI, +2 to +5%]) but reduced the sensitivity (-10% [95% CI, -4 to -15%]). Patients with previous TB retested with Xpert can have false-positive results and thus not require treatment. These data inform clinical practice by highlighting the challenges in interpreting Xpert-positive results, underscore the need for culture, and have implications for next-generation ultrasensitive tests. Copyright © 2018 American Society for Microbiology.

  5. [Molecular beacon based PNA-FISH method combined with fluorescence scanning for rapid detection of Listeria monocytogenes].

    PubMed

    Wu, Shan; Zhang, Xiaofeng; Shuai, Jiangbing; Li, Ke; Yu, Huizhen; Jin, Chenchen

    2016-07-04

    To simplify the PNA-FISH (Peptide nucleic acid-fluorescence in situ hybridization) test, molecular beacon based PNA probe combined with fluorescence scanning detection technology was applied to replace the original microscope observation to detect Listeria monocytogenes The 5′ end and 3′ end of the L. monocytogenes specific PNA probes were labeled with the fluorescent group and the quenching group respectively, to form a molecular beacon based PNA probe. When PNA probe used for fluorescence scanning and N1 treatment as the control, the false positive rate was 11.4%, and the false negative rate was 0; when N2 treatment as the control, the false positive rate decreased to 4.3%, but the false negative rate rose to 18.6%. When beacon based PNA probe used for fluorescence scanning, taken N1 treatment as blank control, the false positive rate was 8.6%, and the false negative rate was 1.4%; taken N2 treatment as blank control, the false positive rate was 5.7%, and the false negative rate was 1.4%. Compared with PNA probe, molecular beacon based PNA probe can effectively reduce false positives and false negatives. The success rates of hybridization of the two PNA probes were 83.3% and 95.2% respectively; and the rates of the two beacon based PNA probes were 91.7% and 90.5% respectively, which indicated that labeling the both ends of the PNA probe dose not decrease the hybridization rate with the target bacteria. The combination of liquid phase PNA-FISH and fluorescence scanning method, can significantly improve the detection efficiency.

  6. Diurnal rhythm and concordance between objective and subjective hot flashes: the Hilo Women's Health Study.

    PubMed

    Sievert, Lynnette L; Reza, Angela; Mills, Phoebe; Morrison, Lynn; Rahberg, Nichole; Goodloe, Amber; Sutherland, Michael; Brown, Daniel E

    2010-01-01

    The aims of this study were to test for a diurnal pattern in hot flashes in a multiethnic population living in a hot, humid environment and to examine the rates of concordance between objective and subjective measures of hot flashes using ambulatory and laboratory measures. Study participants aged 45 to 55 years were recruited from the general population of Hilo, HI. Women wore a Biolog hot flash monitor (UFI, Morro Bay, CA), kept a diary for 24 hours, and also participated in 3-hour laboratory measures (n = 199). Diurnal patterns were assessed using polynomial regression. For each woman, objectively recorded hot flashes that matched subjective experience were treated as true-positive readings. Subjective hot flashes were considered the standard for computing false-positive and false-negative readings. True-positive, false-positive, and false-negative readings were compared across ethnic groups by chi analyses. Frequencies of sternal, nuchal, and subjective hot flashes peaked at 1500 +/- 1 hours with no difference by ethnicity. Laboratory results supported the pattern seen in ambulatory monitoring. Sternal and nuchal monitoring showed the same frequency of true-positive measures, but nonsternal electrodes picked up more false-positive readings. Laboratory monitoring showed very low frequencies of false negatives. There were no ethnic differences in the frequency of true-positive or false-positive measures. Women of European descent were more likely to report hot flashes that were not objectively demonstrated (false-negative measures). The diurnal pattern and peak in hot flash occurrence in the hot humid environment of Hilo were similar to results from more temperate environments. Lack of variation in sternal versus nonsternal measures and in true-positive measures across ethnicities suggests no appreciable effect of population variation in sweating patterns.

  7. Diurnal rhythm and concordance between objective and subjective hot flashes: The Hilo Women’s Health Study

    PubMed Central

    Sievert, Lynnette L.; Reza, Angela; Mills, Phoebe; Morrison, Lynn; Rahberg, Nichole; Goodloe, Amber; Sutherland, Michael; Brown, Daniel E.

    2010-01-01

    Objective To test for a diurnal pattern in hot flashes in a multi-ethnic population living in a hot, humid environment. To examine rates of concordance between objective and subjective measures of hot flashes using ambulatory and laboratory measures. Methods Study participants aged 45–55 were recruited from the general population of Hilo, Hawaii. Women wore a Biolog hot flash monitor, kept a diary for 24-hours, and also participated in 3-hour laboratory measures (n=199). Diurnal patterns were assessed using polynomial regression. For each woman, objectively recorded hot flashes that matched subjective experience were treated as true positive readings. Subjective hot flashes were considered the standard for computing false positive and false negative readings. True positive, false positive, and false negative readings were compared across ethnic groups by chi-square analyses. Results Frequencies of sternal, nuchal and subjective hot flashes peaked at 15:00 ± 1 hour with no difference by ethnicity. Laboratory results supported the pattern seen in ambulatory monitoring. Sternal and nuchal monitoring showed the same frequency of true positive measures, but non-sternal electrodes picked up more false positive readings. Laboratory monitoring showed very low frequencies of false negatives. There were no ethnic differences in the frequency of true positive or false positive measures. Women of European descent were more likely to report hot flashes that were not objectively demonstrated (false negative measures). Conclusions The diurnal pattern and peak in hot flash occurrence in the hot humid environment of Hilo was similar to results from more temperate environments. Lack of variation in sternal vs. non-sternal measures, and in true positive measures across ethnicities suggests no appreciable effect of population variation in sweating patterns. PMID:20220538

  8. Interval Breast Cancer Rates and Histopathologic Tumor Characteristics after False-Positive Findings at Mammography in a Population-based Screening Program.

    PubMed

    Hofvind, Solveig; Sagstad, Silje; Sebuødegård, Sofie; Chen, Ying; Roman, Marta; Lee, Christoph I

    2018-04-01

    Purpose To compare rates and tumor characteristics of interval breast cancers (IBCs) detected after a negative versus false-positive screening among women participating in the Norwegian Breast Cancer Screening Program. Materials and Methods The Cancer Registry Regulation approved this retrospective study. Information about 423 445 women aged 49-71 years who underwent 789 481 full-field digital mammographic screening examinations during 2004-2012 was extracted from the Cancer Registry of Norway. Rates and odds ratios of IBC among women with a negative (the reference group) versus a false-positive screening were estimated by using logistic regression models adjusted for age at diagnosis and county of residence. Results A total of 1302 IBCs were diagnosed after 789 481 screening examinations, of which 7.0% (91 of 1302) were detected among women with a false-positive screening as the most recent breast imaging examination before detection. By using negative screening as the reference, adjusted odds ratios of IBCs were 3.3 (95% confidence interval [CI]: 2.6, 4.2) and 2.8 (95% CI: 1.8, 4.4) for women with a false-positive screening without and with needle biopsy, respectively. Women with a previous negative screening had a significantly lower proportion of tumors that were 10 mm or less (14.3% [150 of 1049] vs 50.0% [seven of 14], respectively; P < .01) and grade I tumors (13.2% [147 of 1114] vs 42.9% [six of 14]; P < .01), but a higher proportion of cases with lymph nodes positive for cancer (40.9% [442 of 1080] vs 13.3% [two of 15], respectively; P = .03) compared with women with a previous false-positive screening with benign biopsy. A retrospective review of the screening mammographic examinations identified 42.9% (39 of 91) of the false-positive cases to be the same lesion as the IBC. Conclusion By using a negative screening as the reference, a false-positive screening examination increased the risk of an IBC three-fold. The tumor characteristics of IBC after a negative screening were less favorable compared with those detected after a previous false-positive screening. © RSNA, 2017 Online supplemental material is available for this article.

  9. A statistical model of false negative and false positive detection of phase singularities.

    PubMed

    Jacquemet, Vincent

    2017-10-01

    The complexity of cardiac fibrillation dynamics can be assessed by analyzing the distribution of phase singularities (PSs) observed using mapping systems. Interelectrode distance, however, limits the accuracy of PS detection. To investigate in a theoretical framework the PS false negative and false positive rates in relation to the characteristics of the mapping system and fibrillation dynamics, we propose a statistical model of phase maps with controllable number and locations of PSs. In this model, phase maps are generated from randomly distributed PSs with physiologically-plausible directions of rotation. Noise and distortion of the phase are added. PSs are detected using topological charge contour integrals on regular grids of varying resolutions. Over 100 × 10 6 realizations of the random field process are used to estimate average false negative and false positive rates using a Monte-Carlo approach. The false detection rates are shown to depend on the average distance between neighboring PSs expressed in units of interelectrode distance, following approximately a power law with exponents in the range of 1.14 to 2 for false negatives and around 2.8 for false positives. In the presence of noise or distortion of phase, false detection rates at high resolution tend to a non-zero noise-dependent lower bound. This model provides an easy-to-implement tool for benchmarking PS detection algorithms over a broad range of configurations with multiple PSs.

  10. The efficacy and cost of alternative strategies for systematic screening for type 2 diabetes in the U.S. population 45-74 years of age.

    PubMed

    Johnson, Susan L; Tabaei, Bahman P; Herman, William H

    2005-02-01

    To simulate the outcomes of alternative strategies for screening the U.S. population 45-74 years of age for type 2 diabetes. We simulated screening with random plasma glucose (RPG) and cut points of 100, 130, and 160 mg/dl and a multivariate equation including RPG and other variables. Over 15 years, we simulated screening at intervals of 1, 3, and 5 years. All positive screening tests were followed by a diagnostic fasting plasma glucose or an oral glucose tolerance test. Outcomes include the numbers of false-negative, true-positive, and false-positive screening tests and the direct and indirect costs. At year 15, screening every 3 years with an RPG cut point of 100 mg/dl left 0.2 million false negatives, an RPG of 130 mg/dl or the equation left 1.3 million false negatives, and an RPG of 160 mg/dl left 2.8 million false negatives. Over 15 years, the absolute difference between the most sensitive and most specific screening strategy was 4.5 million true positives and 476 million false-positives. Strategies using RPG cut points of 130 mg/dl or the multivariate equation every 3 years identified 17.3 million true positives; however, the equation identified fewer false-positives. The total cost of the most sensitive screening strategy was $42.7 billion and that of the most specific strategy was $6.9 billion. Screening for type 2 diabetes every 3 years with an RPG cut point of 130 mg/dl or the multivariate equation provides good yield and minimizes false-positive screening tests and costs.

  11. Diagnostic value and cost utility analysis for urine Gram stain and urine microscopic examination as screening tests for urinary tract infection.

    PubMed

    Wiwanitkit, Viroj; Udomsantisuk, Nibhond; Boonchalermvichian, Chaiyaporn

    2005-06-01

    The aim of this study was to evaluate the diagnostic properties of urine Gram stain and urine microscopic examination for screening for urinary tract infection (UTI), and to perform an additional cost utility analysis. This descriptive study was performed on 95 urine samples sent for urine culture to the Department of Microbiology, Faculty of Medicine, Chulalongkorn University. The first part of the study was to determine the diagnostic properties of two screening tests (urine Gram stain and urine microscopic examination). Urine culture was set as the gold standard and the results from both methods were compared to this. The second part of this study was to perform a cost utility analysis. The sensitivity of urine Gram stain was 96.2%, the specificity 93.0%, the positive predictive value 94.3% and the negative predictive value 95.2%. False positives occurred with a frequency of 7.0% and false negatives 3.8%. For the microscopic examination, the sensitivity was 65.4%, specificity 74.4%, positive predictive value 75.6% and negative predictive value 64.0%. False positives occurred with a frequency of 25.6% and false negatives 34.6%. Combining urine Gram stain and urine microscopic examination, the sensitivity was 98.1%, specificity 74.4%, positive predictive value 82.3% and negative predictive value 97.0%. False positives occurred with a frequency of 25.6% and false negatives 1.9%. However, the cost per utility of the combined method was higher than either urine microscopic examination or urine Gram stain alone. Urine Gram stain provided the lowest cost per utility. Economically, urine Gram stain is the proper screening tool for presumptive diagnosis of UTI.

  12. The accuracy of HIV rapid testing in integrated bio-behavioral surveys of men who have sex with men across 5 Provinces in South Africa

    PubMed Central

    Kufa, Tendesayi; Lane, Tim; Manyuchi, Albert; Singh, Beverley; Isdahl, Zachary; Osmand, Thomas; Grasso, Mike; Struthers, Helen; McIntyre, James; Chipeta, Zawadi; Puren, Adrian

    2017-01-01

    Abstract We describe the accuracy of serial rapid HIV testing among men who have sex with men (MSM) in South Africa and discuss the implications for HIV testing and prevention. This was a cross-sectional survey conducted at five stand-alone facilities from five provinces. Demographic, behavioral, and clinical data were collected. Dried blood spots were obtained for HIV-related testing. Participants were offered rapid HIV testing using 2 rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using a third-generation enzyme immunoassay (EIA) and a fourth-generation EIA as confirmatory. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive, and false-negative rates were determined. Between August 2015 and July 2016, 2503 participants were enrolled. Of these, 2343 were tested by RDT on site with a further 2137 (91.2%) having definitive results on both RDT and EIA. Sensitivity, specificity, positive predictive value, negative predictive value, false-positive rates, and false-negative rates were 92.6% [95% confidence interval (95% CI) 89.6–94.8], 99.4% (95% CI 98.9–99.7), 97.4% (95% CI 95.2–98.6), 98.3% (95% CI 97.6–98.8), 0.6% (95% CI 0.3–1.1), and 7.4% (95% CI 5.2–10.4), respectively. False negatives were similar to true positives with respect to virological profiles. Overall accuracy of the RDT algorithm was high, but sensitivity was lower than expected. Post-HIV test counseling should include discussions of possible false-negative results and the need for retesting among HIV negatives. PMID:28700474

  13. Affective valence influences participant's susceptibility to false memories and illusory recollection.

    PubMed

    Dehon, Hedwige; Larøi, Frank; Van der Linden, Martial

    2010-10-01

    This study examined the influence of emotional valence on the production of DRM false memories (Roediger & McDermott, 1995). Participants were presented with neutral, positive, or negative DRM lists for a later recognition (Experiment 1) or recall (Experiment 2) test. In both experiments, confidence and recollective experience (i.e., "Remember-Know" judgments; Tulving, 1985) were also assessed. Results consistently showed that, compared with neutral lists, affective lists induced more false recognition and recall of nonpresented critical lures. Moreover, although confidence ratings did not differ between the false remembering from the different kinds of lists, "Remember" responses were more often associated with negative than positive and neutral false remembering of the critical lures. In contrast, positive false remembering of the critical lures was more often associated with "Know" responses. These results are discussed in light of the Paradoxical Negative Emotion (PNE) hypothesis (Porter, Taylor, & ten Bricke, 2008). (PsycINFO Database Record (c) 2010 APA, all rights reserved).

  14. Statistical approaches to account for false-positive errors in environmental DNA samples.

    PubMed

    Lahoz-Monfort, José J; Guillera-Arroita, Gurutzeta; Tingley, Reid

    2016-05-01

    Environmental DNA (eDNA) sampling is prone to both false-positive and false-negative errors. We review statistical methods to account for such errors in the analysis of eDNA data and use simulations to compare the performance of different modelling approaches. Our simulations illustrate that even low false-positive rates can produce biased estimates of occupancy and detectability. We further show that removing or classifying single PCR detections in an ad hoc manner under the suspicion that such records represent false positives, as sometimes advocated in the eDNA literature, also results in biased estimation of occupancy, detectability and false-positive rates. We advocate alternative approaches to account for false-positive errors that rely on prior information, or the collection of ancillary detection data at a subset of sites using a sampling method that is not prone to false-positive errors. We illustrate the advantages of these approaches over ad hoc classifications of detections and provide practical advice and code for fitting these models in maximum likelihood and Bayesian frameworks. Given the severe bias induced by false-negative and false-positive errors, the methods presented here should be more routinely adopted in eDNA studies. © 2015 John Wiley & Sons Ltd.

  15. Impact of false-negative sentinel lymph node biopsy on survival in patients with cutaneous melanoma.

    PubMed

    Caracò, C; Marone, U; Celentano, E; Botti, G; Mozzillo, N

    2007-09-01

    Sentinel lymph node biopsy is widely accepted as standard care in melanoma despite lack of pertinent randomized trials results. A possible pitfall of this procedure is the inaccurate identification of the sentinel lymph node leading to biopsy and analysis of a nonsentinel node. Such a technical failure may yield a different prognosis. The purpose of this study is to analyze the incidence of false negativity and its impact on clinical outcome and to try to understand its causes. The Melanoma Data Base at National Cancer Institute of Naples was analyzed comparing results between false-negative and tumor-positive sentinel node patients focusing on overall survival and prognostic factors influencing the clinical outcome. One hundred fifty-one cases were diagnosed to be tumor-positive after sentinel lymph node biopsy and were subjected to complete lymph node dissection. Thirty-four (18.4%)patients with tumor-negative sentinel node subsequently developed lymph node metastases in the basin site of the sentinel procedure. With a median follow-up of 42.8 months the 5-year overall survival was 48.4% and 66.3% for false-negative and tumor-positive group respectively with significant statistical differences (P < .03). The sensitivity of sentinel lymph node biopsy was 81.6%, and a regional nodal basin recurrence after negative-sentinel node biopsy means a worse prognosis, compared with patients submitted to complete lymph node dissection after a positive sentinel biopsy. The evidence of higher number of tumor-positive nodes after delayed lymphadenectomy in false-negative group compared with tumor-positive sentinel node cases, confirmed the importance of an early staging of lymph nodal involvement. Further data will better clarify the role of prognostic factors to identify cases with a more aggressive biological behavior of the disease.

  16. [Evaluation of performance of five bioinformatics software for the prediction of missense mutations].

    PubMed

    Chen, Qianting; Dai, Congling; Zhang, Qianjun; Du, Juan; Li, Wen

    2016-10-01

    To study the prediction performance evaluation with five kinds of bioinformatics software (SIFT, PolyPhen2, MutationTaster, Provean, MutationAssessor). From own database for genetic mutations collected over the past five years, Chinese literature database, Human Gene Mutation Database, and dbSNP, 121 missense mutations confirmed by functional studies, and 121 missense mutations suspected to be pathogenic by pedigree analysis were used as positive gold standard, while 242 missense mutations with minor allele frequency (MAF)>5% in dominant hereditary diseases were used as negative gold standard. The selected mutations were predicted with the five software. Based on the results, the performance of the five software was evaluated for their sensitivity, specificity, positive predict value, false positive rate, negative predict value, false negative rate, false discovery rate, accuracy, and receiver operating characteristic curve (ROC). In terms of sensitivity, negative predictive value and false negative rate, the rank was MutationTaster, PolyPhen2, Provean, SIFT, and MutationAssessor. For specificity and false positive rate, the rank was MutationTaster, Provean, MutationAssessor, SIFT, and PolyPhen2. For positive predict value and false discovery rate, the rank was MutationTaster, Provean, MutationAssessor, PolyPhen2, and SIFT. For area under the ROC curve (AUC) and accuracy, the rank was MutationTaster, Provean, PolyPhen2, MutationAssessor, and SIFT. The prediction performance of software may be different when using different parameters. Among the five software, MutationTaster has the best prediction performance.

  17. DNA typing by microbead arrays and PCR-SSP: apparent false-negative or -positive hybridization or amplification signals disclose new HLA-B and -DRB1 alleles.

    PubMed

    Rahal, M; Kervaire, B; Villard, J; Tiercy, J-M

    2008-03-01

    Human leukocyte antigen (HLA) typing by polymerase chain reaction-sequence-specific oligonucleotide (PCR-SSO) hybridization on solid phase (microbead assay) or polymerase chain reaction-sequence-specific primers (PCR-SSP) requires interpretation softwares to detect all possible allele combinations. These programs propose allele calls by taking into account false-positive or false-negative signal(s). The laboratory has the option to validate typing results in the presence of strongly cross-reacting or apparent false-negative signals. Alternatively, these seemingly aberrant signals may disclose novel variants. We report here four new HLA-B (B*5620 and B*5716) and HLA-DRB1 alleles (DRB1*110107 and DRB1*1474) that were detected by apparent false-negative or -positive hybridization or amplification patterns, and ultimately resolved by sequencing. To avoid allele misassignments, a comprehensive evaluation of acquired data as documented in a quality assurance system is therefore required to confirm unambiguous typing interpretation.

  18. Positive events protect children from causal false memories for scripted events.

    PubMed

    Melinder, Annika; Toffalini, Enrico; Geccherle, Eleonora; Cornoldi, Cesare

    2017-11-01

    Adults produce fewer inferential false memories for scripted events when their conclusions are emotionally charged than when they are neutral, but it is not clear whether the same effect is also found in children. In the present study, we examined this issue in a sample of 132 children aged 6-12 years (mean 9 years, 3 months). Participants encoded photographs depicting six script-like events that had a positively, negatively, or a neutral valenced ending. Subsequently, true and false recognition memory of photographs related to the observed scripts was tested as a function of emotionality. Causal errors-a type of false memory thought to stem from inferential processes-were found to be affected by valence: children made fewer causal errors for positive than for neutral or negative events. Hypotheses are proposed on why adults were found protected against inferential false memories not only by positive (as for children) but also by negative endings when administered similar versions of the same paradigm.

  19. Experimental investigation of false positive errors in auditory species occurrence surveys

    USGS Publications Warehouse

    Miller, David A.W.; Weir, Linda A.; McClintock, Brett T.; Grant, Evan H. Campbell; Bailey, Larissa L.; Simons, Theodore R.

    2012-01-01

    False positive errors are a significant component of many ecological data sets, which in combination with false negative errors, can lead to severe biases in conclusions about ecological systems. We present results of a field experiment where observers recorded observations for known combinations of electronically broadcast calling anurans under conditions mimicking field surveys to determine species occurrence. Our objectives were to characterize false positive error probabilities for auditory methods based on a large number of observers, to determine if targeted instruction could be used to reduce false positive error rates, and to establish useful predictors of among-observer and among-species differences in error rates. We recruited 31 observers, ranging in abilities from novice to expert, that recorded detections for 12 species during 180 calling trials (66,960 total observations). All observers made multiple false positive errors and on average 8.1% of recorded detections in the experiment were false positive errors. Additional instruction had only minor effects on error rates. After instruction, false positive error probabilities decreased by 16% for treatment individuals compared to controls with broad confidence interval overlap of 0 (95% CI: -46 to 30%). This coincided with an increase in false negative errors due to the treatment (26%; -3 to 61%). Differences among observers in false positive and in false negative error rates were best predicted by scores from an online test and a self-assessment of observer ability completed prior to the field experiment. In contrast, years of experience conducting call surveys was a weak predictor of error rates. False positive errors were also more common for species that were played more frequently, but were not related to the dominant spectral frequency of the call. Our results corroborate other work that demonstrates false positives are a significant component of species occurrence data collected by auditory methods. Instructing observers to only report detections they are completely certain are correct is not sufficient to eliminate errors. As a result, analytical methods that account for false positive errors will be needed, and independent testing of observer ability is a useful predictor for among-observer variation in observation error rates.

  20. False Positive and False Negative Effects on Network Attacks

    NASA Astrophysics Data System (ADS)

    Shang, Yilun

    2018-01-01

    Robustness against attacks serves as evidence for complex network structures and failure mechanisms that lie behind them. Most often, due to detection capability limitation or good disguises, attacks on networks are subject to false positives and false negatives, meaning that functional nodes may be falsely regarded as compromised by the attacker and vice versa. In this work, we initiate a study of false positive/negative effects on network robustness against three fundamental types of attack strategies, namely, random attacks (RA), localized attacks (LA), and targeted attack (TA). By developing a general mathematical framework based upon the percolation model, we investigate analytically and by numerical simulations of attack robustness with false positive/negative rate (FPR/FNR) on three benchmark models including Erdős-Rényi (ER) networks, random regular (RR) networks, and scale-free (SF) networks. We show that ER networks are equivalently robust against RA and LA only when FPR equals zero or the initial network is intact. We find several interesting crossovers in RR and SF networks when FPR is taken into consideration. By defining the cost of attack, we observe diminishing marginal attack efficiency for RA, LA, and TA. Our finding highlights the potential risk of underestimating or ignoring FPR in understanding attack robustness. The results may provide insights into ways of enhancing robustness of network architecture and improve the level of protection of critical infrastructures.

  1. True detection limits in an experimental linearly heteroscedastic system. Part 1

    NASA Astrophysics Data System (ADS)

    Voigtman, Edward; Abraham, Kevin T.

    2011-11-01

    Using a lab-constructed laser-excited filter fluorimeter deliberately designed to exhibit linearly heteroscedastic, additive Gaussian noise, it has been shown that accurate estimates may be made of the true theoretical Currie decision levels ( YC and XC) and true Currie detection limits ( YD and XD) for the detection of rhodamine 6 G tetrafluoroborate in ethanol. The obtained experimental values, for 5% probability of false positives and 5% probability of false negatives, were YC = 56.1 mV, YD = 125. mV, XC = 0.132 μg /mL and XD = 0.294 μg /mL. For 5% probability of false positives and 1% probability of false negatives, the obtained detection limits were YD = 158. mV and XD = 0.372 μg /mL. These decision levels and corresponding detection limits were shown to pass the ultimate test: they resulted in observed probabilities of false positives and false negatives that were statistically equivalent to the a priori specified values.

  2. The incidence and clinical implication of sputum with positive acid-fast bacilli smear but negative in mycobacterial culture in a tertiary referral hospital in South Korea.

    PubMed

    Lee, Jae Seok; Kim, Eui-Chong; Joo, Sei Ick; Lee, Sang-Min; Yoo, Chul-Gyu; Kim, Young Whan; Han, Sung Koo; Shim, Young-Soo; Yim, Jae-Joon

    2008-10-01

    Although it is not rare to find sputum that is positive acid-fast bacilli (AFB) smear but subsequent culture fails to isolate mycobacteria in clinical practice, the incidence and clinical implication of those sputa from new patients has not been clearly elucidated. The aim of this study was to determine the incidence and clinical implication of sputum with positive AFB smear but negative in mycobacterial culture. All sputa that were positive AFB smear requested during diagnostic work up for new patients visiting Seoul National University Hospital from 1 January 2005 through 31 December 2006 were included. Sputa producing a positive AFB smear but negative mycobacterial culture were classified into one of four categories: laboratory failure to isolate mycobacteria, false positive AFB smear, pathogen may show a positive AFB smear other than mycobacteria, and indeterminate results. Out of 447 sputa with a positive AFB smear, 29 (6.5%) failed to culture any organism. Among these 29 sputa, 18 were caused by laboratory failure to isolate mycobacteria, six were false positive smears, and five indeterminate. Although most sputum with a positive AFB smear but negative culture could be classified as a laboratory failure, clinicians should consider the possibility of false positive AFB smear.

  3. Evaluation of musculoskeletal sepsis with indium-111 white blood cell imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ouzounian, T.J.; Thompson, L.; Grogan, T.J.

    The detection of musculoskeletal sepsis, especially following joint replacement, continues to be a challenging problem. Often, even with invasive diagnostic evaluation, the diagnosis of infection remains uncertain. This is a report on the first 55 Indium-111 white blood cell (WBC) images performed in 39 patients for the evaluation of musculoskeletal sepsis. There were 40 negative and 15 positive Indium-111 WBC images. These were correlated with operative culture and tissue pathology, aspiration culture, and clinical findings. Thirty-eight images were performed for the evaluation of possible total joint sepsis (8 positive and 30 negative images); 17 for the evaluation of nonarthroplasty-related musculoskeletalmore » sepsis (7 positive and 10 negative images). Overall, there were 13 true-positive, 39 true-negative, two false-positive, and one false-negative images. Indium-111 WBC imaging is a sensitive and specific means of evaluating musculoskeletal sepsis, especially following total joint replacement.« less

  4. Nonbleeding adenomas: Evidence of systematic false-negative fecal immunochemical test results and their implications for screening effectiveness-A modeling study.

    PubMed

    van der Meulen, Miriam P; Lansdorp-Vogelaar, Iris; van Heijningen, Else-Mariëtte B; Kuipers, Ernst J; van Ballegooijen, Marjolein

    2016-06-01

    If some adenomas do not bleed over several years, they will cause systematic false-negative fecal immunochemical test (FIT) results. The long-term effectiveness of FIT screening has been estimated without accounting for such systematic false-negativity. There are now data with which to evaluate this issue. The authors developed one microsimulation model (MISCAN [MIcrosimulation SCreening ANalysis]-Colon) without systematic false-negative FIT results and one model that allowed a percentage of adenomas to be systematically missed in successive FIT screening rounds. Both variants were adjusted to reproduce the first-round findings of the Dutch CORERO FIT screening trial. The authors then compared simulated detection rates in the second screening round with those observed, and adjusted the simulated percentage of systematically missed adenomas to those data. Finally, the authors calculated the impact of systematic false-negative FIT results on the effectiveness of repeated FIT screening. The model without systematic false-negativity simulated higher detection rates in the second screening round than observed. These observed rates could be reproduced when assuming that FIT systematically missed 26% of advanced and 73% of nonadvanced adenomas. To reduce the false-positive rate in the second round to the observed level, the authors also had to assume that 30% of false-positive findings were systematically false-positive. Systematic false-negative FIT testing limits the long-term reduction of biennial FIT screening in the incidence of colorectal cancer (35.6% vs 40.9%) and its mortality (55.2% vs 59.0%) in participants. The results of the current study provide convincing evidence based on the combination of real-life and modeling data that a percentage of adenomas are systematically missed by repeat FIT screening. This impairs the efficacy of FIT screening. Cancer 2016;122:1680-8. © 2016 American Cancer Society. © 2016 American Cancer Society.

  5. The value of a transformation zone component in anal cytology to detect HSIL.

    PubMed

    Roberts, Jennifer M; Jin, Fengyi; Thurloe, Julia K; Ekman, Deborah; Adams, Marjorie K; McDonald, Ross L; Biro, Clare; Poynten, I Mary; Grulich, Andrew E; Farnsworth, Annabelle

    2016-08-01

    In a cytology-based screening program intended to prevent anal cancer, the anal transformation zone (TZ) should be adequately sampled because it is the site most susceptible to the development of the cancer precursor, high-grade squamous intraepithelial lesion (HSIL). An adequate TZ component is defined as comprising at least 10 rectal columnar or squamous metaplastic cells. In the current study, the authors examined whether the presence of a TZ component in anal cytology correlated with the detection of histological HSIL. In a natural history study of anal human papillomavirus infection in homosexual men, all participants underwent liquid-based cytology and high-resolution anoscopy (HRA) with or without biopsy at each visit. True-negative cytology (negative cytology with non-HSIL biopsy or negative HRA), false-negative cytology (negative cytology with HSIL biopsy), and true-positive cytology (abnormal cytology with HSIL biopsy) were compared with regard to the presence or absence of a TZ component. Of 617 participants, baseline results included 155 true-positive results, 191 true-negative results, and 31 false-negative results. The absence of an adequate TZ component was found to be significantly higher for false-negative (32.3%) than for either true-positive (11.0%; P = .0034) or true-negative (13.1%; P = .0089) results. Significantly more false-negative cases lacked a TZ component compared with either true-positive or true-negative cases. TZ cells may be an important indicator of sample quality for anal cytology because, unlike cervical sampling, the anal canal is not visualized during cytology sampling. Cancer Cytopathol 2016;124:596-601. © 2016 American Cancer Society. © 2016 American Cancer Society.

  6. Rapid automated method for screening of enteric pathogens from stool specimens.

    PubMed Central

    Villasante, P A; Agulla, A; Merino, F J; Pérez, T; Ladrón de Guevara, C; Velasco, A C

    1987-01-01

    A total of 800 colonies suggestive of Salmonella, Shigella, or Yersinia species isolated on stool differential agar media were inoculated onto both conventional biochemical test media (triple sugar iron agar, urea agar, and phenylalanine agar) and Entero Pathogen Screen cards of the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). Based on the conventional tests, the AutoMicrobic system method yielded the following results: 587 true-negatives, 185 true-positives, 2 false-negatives, and 26 false-positives (sensitivity, 99%; specificity, 96%). Both true-positive and true-negative results were achieved considerably earlier than false results (P less than 0.001). The Entero Pathogen Screen card method is a fast, easy, and sensitive method for screening for Salmonella, Shigella, or Yersinia species. The impossibility of screening for oxidase-positive pathogens is a minor disadvantage of this method. PMID:3553230

  7. Comparing diagnostic tests on benefit-risk.

    PubMed

    Pennello, Gene; Pantoja-Galicia, Norberto; Evans, Scott

    2016-01-01

    Comparing diagnostic tests on accuracy alone can be inconclusive. For example, a test may have better sensitivity than another test yet worse specificity. Comparing tests on benefit risk may be more conclusive because clinical consequences of diagnostic error are considered. For benefit-risk evaluation, we propose diagnostic yield, the expected distribution of subjects with true positive, false positive, true negative, and false negative test results in a hypothetical population. We construct a table of diagnostic yield that includes the number of false positive subjects experiencing adverse consequences from unnecessary work-up. We then develop a decision theory for evaluating tests. The theory provides additional interpretation to quantities in the diagnostic yield table. It also indicates that the expected utility of a test relative to a perfect test is a weighted accuracy measure, the average of sensitivity and specificity weighted for prevalence and relative importance of false positive and false negative testing errors, also interpretable as the cost-benefit ratio of treating non-diseased and diseased subjects. We propose plots of diagnostic yield, weighted accuracy, and relative net benefit of tests as functions of prevalence or cost-benefit ratio. Concepts are illustrated with hypothetical screening tests for colorectal cancer with test positive subjects being referred to colonoscopy.

  8. False Memories for Affective Information in Schizophrenia.

    PubMed

    Fairfield, Beth; Altamura, Mario; Padalino, Flavia A; Balzotti, Angela; Di Domenico, Alberto; Mammarella, Nicola

    2016-01-01

    Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the to-be-remembered material and false memory occurrence has not yet been studied. In this study, 24 patients and 24 healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative, or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls ( p  < 0.05) when remembering episodes with positive or negative outcomes. The effect of valence was apparent in the patient group. For example, it did not affect the production causal false memories ( p  > 0.05) resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e., neutral episodes yielded a higher degree of errors than positive and negative episodes). Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved.

  9. False Memories for Affective Information in Schizophrenia

    PubMed Central

    Fairfield, Beth; Altamura, Mario; Padalino, Flavia A.; Balzotti, Angela; Di Domenico, Alberto; Mammarella, Nicola

    2016-01-01

    Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the to-be-remembered material and false memory occurrence has not yet been studied. In this study, 24 patients and 24 healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative, or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls (p < 0.05) when remembering episodes with positive or negative outcomes. The effect of valence was apparent in the patient group. For example, it did not affect the production causal false memories (p > 0.05) resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e., neutral episodes yielded a higher degree of errors than positive and negative episodes). Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved. PMID:27965600

  10. Case report: false negative serum cryptococcal latex agglutination test in a patient with disseminated cryptococcal disease.

    PubMed

    Navabi, Nazlee; Montebatsi, Milton; Scott, Michelle; Gluckman, Stephen J; Reid, Michael J A

    2015-01-01

    A case of false-negative serum latex agglutination cryptococcal antigen (CRAG) test in a 45-year-old HIV-positive male with Cryptococcus-positive culture is described. The patient was presented to a hospital in Botswana, with breathlessness and a diffuse papular rash. His CD4 count was 25 cells/μL. Despite the suspicion for disseminated cryptococcal disease, an initial serum CRAG latex test was negative. Results of subsequent Indian ink staining, culture of cerebrospinal fluid and skin scrapings, and serum lateral flow immunoassay (LFA) were all positive for Cryptococcus neoformans. There are several possible explanations for the false-negative CRAG latex test. Given the positive LFA result, we speculate that disease may have been caused by Cryptococcus gattii, which is estimated to be responsible for between 15% and 30% of all cryptococcal diseases in Botswana. Reduced sensitivity of CRAG latex assays for detecting C gattii may lead to underdiagnosis of cryptococcal infection. © The Author(s) 2014.

  11. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    PubMed Central

    Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M. Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz

    2015-01-01

    Background Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Methodology/Principal Findings Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). Conclusion The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study. PMID:26161864

  12. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    PubMed

    Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz

    2015-01-01

    Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  13. Two-step glutamate dehydrogenase antigen real-time polymerase chain reaction assay for detection of toxigenic Clostridium difficile.

    PubMed

    Goldenberg, S D; Cliff, P R; Smith, S; Milner, M; French, G L

    2010-01-01

    Current diagnosis of Clostridium difficile infection (CDI) relies upon detection of toxins A/B in stool by enzyme immunoassay [EIA(A/B)]. This strategy is unsatisfactory because it has a low sensitivity resulting in significant false negatives. We investigated the performance of a two-step algorithm for diagnosis of CDI using detection of glutamate dehydrogenase (GDH). GDH-positive samples were tested for C. difficile toxin B gene (tcdB) by polymerase chain reaction (PCR). The performance of the two-step protocol was compared with toxin detection by the Meridian Premier EIA kit in 500 consecutive stool samples from patients with suspected CDI. The reference standard among samples that were positive by either EIA(A/B) or GDH testing was culture cytotoxin neutralisation (culture/CTN). Thirty-six (7%) of 500 samples were identified as true positives by culture/CTN. EIA(A/B) identified 14 of the positive specimens with 22 false negatives and two false positives. The two-step protocol identified 34 of the positive samples with two false positives and two false negatives. EIA(A/B) had a sensitivity of 39%, specificity of 99%, positive predictive value of 88% and negative predictive value of 95%. The two-step algorithm performed better, with corresponding values of 94%, 99%, 94% and 99% respectively. Screening for GDH before confirmation of positives by PCR is cheaper than screening all specimens by PCR and is an effective method for routine use. Current EIA(A/B) tests for CDI are of inadequate sensitivity and should be replaced; however, this may result in apparent changes in CDI rates that would need to be explained in national surveillance statistics. Copyright 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  14. Standoff detection of chemical and biological threats using laser-induced breakdown spectroscopy.

    PubMed

    Gottfried, Jennifer L; De Lucia, Frank C; Munson, Chase A; Miziolek, Andrzej W

    2008-04-01

    Laser-induced breakdown spectroscopy (LIBS) is a promising technique for real-time chemical and biological warfare agent detection in the field. We have demonstrated the detection and discrimination of the biological warfare agent surrogates Bacillus subtilis (BG) (2% false negatives, 0% false positives) and ovalbumin (0% false negatives, 1% false positives) at 20 meters using standoff laser-induced breakdown spectroscopy (ST-LIBS) and linear correlation. Unknown interferent samples (not included in the model), samples on different substrates, and mixtures of BG and Arizona road dust have been classified with reasonable success using partial least squares discriminant analysis (PLS-DA). A few of the samples tested such as the soot (not included in the model) and the 25% BG:75% dust mixture resulted in a significant number of false positives or false negatives, respectively. Our preliminary results indicate that while LIBS is able to discriminate biomaterials with similar elemental compositions at standoff distances based on differences in key intensity ratios, further work is needed to reduce the number of false positives/negatives by refining the PLS-DA model to include a sufficient range of material classes and carefully selecting a detection threshold. In addition, we have demonstrated that LIBS can distinguish five different organophosphate nerve agent simulants at 20 meters, despite their similar stoichiometric formulas. Finally, a combined PLS-DA model for chemical, biological, and explosives detection using a single ST-LIBS sensor has been developed in order to demonstrate the potential of standoff LIBS for universal hazardous materials detection.

  15. Risk management and precaution: insights on the cautious use of evidence.

    PubMed Central

    Hrudey, Steve E; Leiss, William

    2003-01-01

    Risk management, done well, should be inherently precautionary. Adopting an appropriate degree of precaution with respect to feared health and environmental hazards is fundamental to risk management. The real problem is in deciding how precautionary to be in the face of inevitable uncertainties, demanding that we understand the equally inevitable false positives and false negatives from screening evidence. We consider a framework for detection and judgment of evidence of well-characterized hazards, using the concepts of sensitivity, specificity, positive predictive value, and negative predictive value that are well established for medical diagnosis. Our confidence in predicting the likelihood of a true danger inevitably will be poor for rare hazards because of the predominance of false positives; failing to detect a true danger is less likely because false negatives must be rarer than the danger itself. Because most controversial environmental hazards arise infrequently, this truth poses a dilemma for risk management. PMID:14527835

  16. The effect of mood on false memory for emotional DRM word lists.

    PubMed

    Zhang, Weiwei; Gross, Julien; Hayne, Harlene

    2017-04-01

    In the present study, we investigated the effect of participants' mood on true and false memories of emotional word lists in the Deese-Roediger-McDermott (DRM) paradigm. In Experiment 1, we constructed DRM word lists in which all the studied words and corresponding critical lures reflected a specified emotional valence. In Experiment 2, we used these lists to assess mood-congruent true and false memory. Participants were randomly assigned to one of three induced-mood conditions (positive, negative, or neutral) and were presented with word lists comprised of positive, negative, or neutral words. For both true and false memory, there was a mood-congruent effect in the negative mood condition; this effect was due to a decrease in true and false recognition of the positive and neutral words. These findings are consistent with both spreading-activation and fuzzy-trace theories of DRM performance and have practical implications for our understanding of the effect of mood on memory.

  17. False-negative BRAF V600E mutation results on fine-needle aspiration cytology of papillary thyroid carcinoma.

    PubMed

    Paek, Se Hyun; Kim, Byung Seup; Kang, Kyung Ho; Kim, Hee Sung

    2017-11-13

    The BRAF V600E mutation is highly specific for papillary thyroid carcinoma (PTC). A test for this mutation can increase the diagnostic accuracy of fine-needle aspiration cytology (FNAC), but a considerably high false-negative rate for the BRAF V600E mutation on FNAC has been reported. In this study, we investigated the risk factors associated with false-negative BRAF V600E mutation results on FNAC. BRAF V600E mutation results of 221 PTC nodules between December 2011 and June 2013 were retrospectively reviewed. BRAF V600E mutation results on both preoperative FNAC and postoperative formalin-fixed, paraffin-embedded (FFPE) samples were compared. We investigated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of BRAF V600E mutation results on FNAC. And, we identified the risk factors associated with false-negative results. Of 221 PTC nodules, 150 (67.9%) on FNAC and 185 (83.7%) on FFPE samples were BRAF V600E mutation positive. The sensitivity, specificity, PPV, and NPV for BRAF V600E mutation testing with FNAC were 80.5, 97.2, 99.3, and 49.3%, respectively. Thirty-six (16.3%) BRAF V600E mutation-negative nodules on FNAC were mutation positive on FFPE sample analysis. Risk factors for these false-negative results were age, indeterminate FNAC results (nondiagnostic, atypia of undetermined significance (AUS), and findings suspicious for PTC), and PTC subtype. False-negative rate of BRAF mutation testing with FNAC for thyroid nodules is increased in cases of old age, indeterminate FNAC pathology results, and certain PTC subtypes. Therapeutic surgery can be considered for these cases. A well-designed prospective study with informed consent of patients will be essential for more informative results.

  18. Ventilation/perfusion single-photon emission computed tomography: a service evaluation.

    PubMed

    Parekh, Amit; Graham, Richard; Redman, Stewart

    2017-08-01

    To identify the positive rate and negative predictive value (NPV) of our ventilation/perfusion (V/Q) single-photon emission computed tomography (SPECT) service as respective markers of overcalling (false positives) and undercalling (false negatives). We also identified the indeterminate rate as an indicator of the technical quality of the scans and reporter confidence. V/Q SPECT studies carried out over 5 years were classified into positive, negative and indeterminate results. Patients who had died or had pulmonary emboli on imaging within 3 months of a negative V/Q SPECT were identified as false negatives, from which the NPV was calculated. The total number of positive and indeterminate studies as a proportion of all studies was calculated as the positive and indeterminate rates. The positive rate, NPV and indeterminate rates in nonpregnant patients were 24, 98.7-100 and 3.6%, respectively. The positive rate, NPV and indeterminate rates in pregnant patients were 6.8, 100 and 2.3%, respectively. The positive rate and NPV for nonpregnant patients were similar to the published literature. This suggests that we provide a safe service. The indeterminate rate was slightly higher than the stated guidelines. The study shows that the positive rate and NPV are achievable indicators of potential overcalling and undercalling in a V/Q SPECT service.This is also one of the first studies to report a positive rate in pregnant patients undergoing V/Q SPECT that other institutions can use as a standard when evaluating their services.

  19. A critical reappraisal of false negative sentinel lymph node biopsy in melanoma.

    PubMed

    Manca, G; Romanini, A; Rubello, D; Mazzarri, S; Boni, G; Chiacchio, S; Tredici, M; Duce, V; Tardelli, E; Volterrani, D; Mariani, G

    2014-06-01

    Lymphatic mapping and sentinel lymph node biopsy (SLNB) have completely changed the clinical management of cutaneous melanoma. This procedure has been accepted worldwide as a recognized method for nodal staging. SLNB is able to accurately determine nodal basin status, providing the most useful prognostic information. However, SLNB is not a perfect diagnostic test. Several large-scale studies have reported a relatively high false-negative rate (5.6-21%), correctly defined as the proportion of false-negative results with respect to the total number of "actual" positive lymph nodes. The main purpose of this review is to address the technical issues that nuclear physicians, surgeons, and pathologists should carefully consider to improve the accuracy of SLNB by minimizing its false-negative rate. In particular, SPECT/CT imaging has demonstrated to be able to identify a greater number of sentinel lymph nodes (SLNs) than those found by planar lymphoscintigraphy. Furthermore, a unique definition in the international guidelines is missing for the operational identification of SLNs, which may be partly responsible for this relatively high false-negative rate of SLNB. Therefore, it is recommended for the scientific community to agree on the radioactive counting rate threshold so that the surgeon can be better radioguided to detect all the lymph nodes which are most likely to harbor metastases. Another possible source of error may be linked to the examination of the harvested SLNs by conventional histopathological methods. A more careful and extensive SLN analysis (e.g. molecular analysis by RT-PCR) is able to find more positive nodes, so that the false-negative rate is reduced. Older age at diagnosis, deeper lesions, histologic ulceration, head-neck anatomical location of primary lesions are the clinical factors associated with false-negative SLNBs in melanoma patients. There is still much controversy about the clinical significance of a false-negative SLNB on the prognosis of melanoma patients. Indeed, most studies have failed to show that there is worse melanoma-specific survival for false-negative compared to true-positive SLNB patients.

  20. Where Have All the Interactions Gone? Estimating the Coverage of Two-Hybrid Protein Interaction Maps

    PubMed Central

    Huang, Hailiang; Jedynak, Bruno M; Bader, Joel S

    2007-01-01

    Yeast two-hybrid screens are an important method for mapping pairwise physical interactions between proteins. The fraction of interactions detected in independent screens can be very small, and an outstanding challenge is to determine the reason for the low overlap. Low overlap can arise from either a high false-discovery rate (interaction sets have low overlap because each set is contaminated by a large number of stochastic false-positive interactions) or a high false-negative rate (interaction sets have low overlap because each misses many true interactions). We extend capture–recapture theory to provide the first unified model for false-positive and false-negative rates for two-hybrid screens. Analysis of yeast, worm, and fly data indicates that 25% to 45% of the reported interactions are likely false positives. Membrane proteins have higher false-discovery rates on average, and signal transduction proteins have lower rates. The overall false-negative rate ranges from 75% for worm to 90% for fly, which arises from a roughly 50% false-negative rate due to statistical undersampling and a 55% to 85% false-negative rate due to proteins that appear to be systematically lost from the assays. Finally, statistical model selection conclusively rejects the Erdös-Rényi network model in favor of the power law model for yeast and the truncated power law for worm and fly degree distributions. Much as genome sequencing coverage estimates were essential for planning the human genome sequencing project, the coverage estimates developed here will be valuable for guiding future proteomic screens. All software and datasets are available in Datasets S1 and S2, Figures S1–S5, and Tables S1−S6, and are also available from our Web site, http://www.baderzone.org. PMID:18039026

  1. Influence of clinical and laboratory variables on faecal antigen ELISA results in dogs with canine parvovirus infection.

    PubMed

    Proksch, A L; Unterer, S; Speck, S; Truyen, U; Hartmann, K

    2015-06-01

    False negative faecal canine parvovirus (CPV) antigen ELISA results in dogs with CPV infection are common, but the factors that lead to these false negative results are still unknown. The aim of this study was to investigate whether dogs with a false negative faecal CPV antigen ELISA result have milder clinical signs and laboratory changes, a lower faecal virus load, higher faecal and serum CPV antibody titres and a faster recovery than dogs with a positive result. Eighty dogs with CPV infection, confirmed by the presence of clinical signs and a positive faecal CPV polymerase chain reaction (PCR), were assigned to two groups according to their faecal antigen ELISA result. Time until presentation, severity of symptoms, laboratory parameters, faecal virus load, faecal and serum antibody titres, and CPV sequencing data were compared between both groups. In 38/80 dogs that were hospitalised until recovery, the time to recovery, mortality, and the course of the disease were compared between dogs with positive and negative faecal antigen ELISA results. Of the 80 dogs included, 41 (51.3%) had a false negative faecal antigen ELISA result. ELISA-negative dogs had a significantly shorter time until presentation, lower frequency of defaecation, lower faecal virus load, and higher serum antibody concentrations than ELISA-positive dogs. Laboratory changes, CPV shedding, and outcomes were not associated with faecal antigen ELISA results. In conclusion, low faecal CPV load and antibodies binding to CPV antigen in faeces are likely to be important reasons for false negative faecal antigen ELISA results. Dogs with clinical signs of CPV infection should be retested by faecal PCR. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Comparison of bronchoalveolar lavage cytology and transbronchial biopsy in the diagnosis of carcinoma of lung.

    PubMed

    Ahmed, Ayesha; Ahmed, Sajjad

    2004-01-01

    The objectives of this study were to compare bronchoalveolar lavage (BAL) cytology and transbronchial biopsy in the diagnosis of carcinoma lung and to determine accuracy of BAL cytology using histopathlologic examination of transbronchial biopsy as gold standard at our center. This study was carried out at Department of Histopathology, Ayub Medical College, Abbottabad, from 1.09.2000 to 28.02.2003. BAL fluid and bronchial biopsy were received and processed simultaneously. Four cytology and a set of histopathology slides were prepared. These were screened and diagnosis recorded. Sensitivity, Specificity, False Positive, False Negative, Positive predictive value and Negative predictive value of BAL cytology were determined using histopathology of transbronchial biopsy as gold standard. We found the sensitivity of BAL cytology to be 93.44% as compared with transbronchial biopsy. The specificity was 100%. There was no false positive while false negative results were 6.55 %. The positive predictive value was 100 %, while the negative predictive value was 75 %. The overall diagnostic efficacy of BAL cytology was 94.52 %. BAL cytology is a highly sensitive and specific test for diagnosis of carcinoma lung. It can be used as a quick and reliable diagnostic method for diagnosis of lung malignancy.

  3. Are the memories of older adults positively biased?

    PubMed

    Fernandes, Myra; Ross, Michael; Wiegand, Melanie; Schryer, Emily

    2008-06-01

    There is disagreement in the literature about whether a "positivity effect" in memory performance exists in older adults. To assess the generalizability of the effect, the authors examined memory for autobiographical, picture, and word information in a group of younger (17-29 years old) and older (60-84 years old) adults. For the autobiographical memory task, the authors asked participants to produce 4 positive, 4 negative, and 4 neutral recent autobiographical memories and to recall these a week later. For the picture and word tasks, participants studied photos or words of different valences (positive, negative, neutral) and later remembered them on a free-recall test. The authors found significant correlations in memory performance, across task material, for recall of both positive and neutral valence autobiographical events, pictures, and words. When the authors examined accurate memories, they failed to find consistent evidence, across the different types of material, of a positivity effect in either age group. However, the false memory findings offer more consistent support for a positivity effect in older adults. During recall of all 3 types of material, older participants recalled more false positive than false negative memories.

  4. Uncertainty in biological monitoring: a framework for data collection and analysis to account for multiple sources of sampling bias

    USGS Publications Warehouse

    Ruiz-Gutierrez, Viviana; Hooten, Melvin B.; Campbell Grant, Evan H.

    2016-01-01

    Biological monitoring programmes are increasingly relying upon large volumes of citizen-science data to improve the scope and spatial coverage of information, challenging the scientific community to develop design and model-based approaches to improve inference.Recent statistical models in ecology have been developed to accommodate false-negative errors, although current work points to false-positive errors as equally important sources of bias. This is of particular concern for the success of any monitoring programme given that rates as small as 3% could lead to the overestimation of the occurrence of rare events by as much as 50%, and even small false-positive rates can severely bias estimates of occurrence dynamics.We present an integrated, computationally efficient Bayesian hierarchical model to correct for false-positive and false-negative errors in detection/non-detection data. Our model combines independent, auxiliary data sources with field observations to improve the estimation of false-positive rates, when a subset of field observations cannot be validated a posteriori or assumed as perfect. We evaluated the performance of the model across a range of occurrence rates, false-positive and false-negative errors, and quantity of auxiliary data.The model performed well under all simulated scenarios, and we were able to identify critical auxiliary data characteristics which resulted in improved inference. We applied our false-positive model to a large-scale, citizen-science monitoring programme for anurans in the north-eastern United States, using auxiliary data from an experiment designed to estimate false-positive error rates. Not correcting for false-positive rates resulted in biased estimates of occupancy in 4 of the 10 anuran species we analysed, leading to an overestimation of the average number of occupied survey routes by as much as 70%.The framework we present for data collection and analysis is able to efficiently provide reliable inference for occurrence patterns using data from a citizen-science monitoring programme. However, our approach is applicable to data generated by any type of research and monitoring programme, independent of skill level or scale, when effort is placed on obtaining auxiliary information on false-positive rates.

  5. Evaluation of the Architect HIV Ag/Ab Combo Assay in a low-prevalence setting: The role of samples with a low S/CO ratio.

    PubMed

    Alonso, Roberto; Pérez-García, Felipe; Gijón, Paloma; Collazos, Ana; Bouza, Emilio

    2018-06-01

    The Architect HIV Ag/Ab Combo Assay, a fourth-generation ELISA, has proven to be highly reliable for the diagnosis of HIV infection. However, its high sensitivity may lead to false-positive results. To evaluate the diagnostic performance of Architect in a low-prevalence population and to assess the role of the sample-to-cutoff ratio (S/CO) in reducing the frequency of false-positive results. We conducted a retrospective study of samples analyzed by Architect between January 2015 and June 2017. Positive samples were confirmed by immunoblot (RIBA) or nucleic acid amplification tests (NAATs). Different S/CO thresholds (1, 2.5, 10, 25, and 100) were analyzed to determine sensitivity, specificity, and negative and positive predictive values (NPV, PPV). ROC analysis was used to determine the optimal S/CO. A total of 69,471 samples were analyzed. 709 (1.02%) were positive by Architect. Of these, 63 (8.89%) were false-positive results. Most of them (93.65%) were in samples with S/CO < 100. However, most confirmations by NAATs (12 out of 19 cases) were also recorded for these samples. The optimal S/CO was 2.5, which provided the highest area under the ROC curve (0.9998) and no false-negative results. With this S/CO, sensitivity and specificity were 100.0%, and PPV and NPV were 95.8% and 100.0%, respectively. In addition, the frequency of false-positive results decreased significantly to 4.15%. Although Architect generates a relatively high number of false-positive results, raising the S/CO limit too much to increase specificity can lead to false-negative results, especially in newly infected individuals. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Can missed breast cancer be recognized by regular peer auditing on screening mammography?

    PubMed

    Pan, Huay-Ben; Yang, Tsung-Lung; Hsu, Giu-Cheng; Chiang, Chia-Ling; Huang, Jer-Shyung; Chou, Chen-Pin; Wang, Yen-Chi; Liang, Huei-Lung; Lee, San-Kan; Chou, Yi-Hong; Wong, Kam-Fai

    2012-09-01

    This study was conducted to investigate whether detectable missed breast cancers could be distinguished from truly false negative images in a mammographic screening by a regular peer auditing. Between 2004 and 2007, a total of 311,193 free nationwide biennial mammographic screenings were performed for 50- to 69-year-old women in Taiwan. Retrospectively comparing the records in Taiwan's Cancer registry, 1283 cancers were detected (4.1 per 1000). Of the total, 176 (0.6 per 1000) initial mammographic negative assessments were reported to have cancers (128 traditional films and 48 laser-printed digital images). We selected 186 true negative films (138 traditional films and 48 laser-printed ones) as control group. These were seeded into 4815 films of 2008 images to be audited in 2009. Thirty-four auditors interpreted all the films in a single-blind, randomized, pair-control study. The performance of 34 auditors was analyzed by chi-square test. A p value of < 0.05 was considered significant. Eight (6 traditional and 2 digital films) of the 176 false negative films were not reported by the auditors (missing rate of 4.5%). Of this total, 87 false negatives were reassessed as positive, while 29 of the 186 true negatives were reassessed as positive, making the overall performance of the 34 auditors in interpreting the false negatives and true negatives a specificity of 84.4% and sensitivity of 51.8%. The specificity and sensitivity in traditional films and laser-printed films were 98.6% versus 43.8% and 41.8% versus 78.3%, respectively. Almost 42% of the traditional false negative films had positive reassessment by the auditors, showing a significant difference from the initial screeners (p < 0.001). The specificity of their reinterpretation of laser-printed films was obviously low. Almost 42% of the false negative traditional films were judged as missed cancers in this study. A peer auditing should reduce the probability of missed cancers. 2012 Published by Elsevier B.V

  7. Sadder and less accurate? False memory for negative material in depression.

    PubMed

    Joormann, Jutta; Teachman, Bethany A; Gotlib, Ian H

    2009-05-01

    Previous research has demonstrated that induced sad mood is associated with increased accuracy of recall in certain memory tasks; the effects of clinical depression, however, are likely to be quite different. The authors used the Deese-Roediger-McDermott paradigm to examine the impact of clinical depression on erroneous recall of neutral and/or emotional stimuli. Specifically, they presented Deese-Roediger-McDermott lists that were highly associated with negative, neutral, or positive lures and compared participants diagnosed with major depressive disorder and nondepressed control participants on the accuracy of their recall of presented material and their false recall of never-presented lures. Compared with control participants, major depressive disorder participants recalled fewer words that had been previously presented but were more likely to falsely recall negative lures; there were no differences between major depressive disorder and control participants in false recall of positive or neutral lures. These findings indicate that depression is associated with false memories of negative material.

  8. The Diagnostic Validity of the 13C-Urea Breath Test in the Gastrectomized Patients: Single Tertiary Center Retrospective Cohort Study

    PubMed Central

    Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho

    2014-01-01

    Background: This study was conducted to evaluate the diagnostic validity of the 13C-urea breath test (13C-UBT) in the remnant stomach after partial gastrectomy for gastric cancer. Methods: The 13C-UBT results after Helicobacter pylori eradication therapy was compared with the results of endoscopic biopsy-based methods in the patients who have received partial gastrectomy for the gastric cancer. Results: Among the gastrectomized patients who showed the positive 13C-UBT results (≥ 2.5‰, n = 47) and negative 13C-UBT results (< 2.5‰, n = 114) after H. pylori eradication, 26 patients (16.1%) and 4 patients (2.5%) were found to show false positive and false negative results based on biopsy-based methods, respectively. The sensitivity, specificity, false positive rate, and false negative rate for the cut-off value of 2.5‰ were 84.0%, 80.9%, 19.1%, and 16.0%, respectively. The positive and negative predictive values were 44.7% and 96.5%, respectively. In the multivariate analysis, two or more H. pylori eradication therapies (odds ratio = 3.248, 95% confidence interval= 1.088–9.695, P = 0.035) was associated with a false positive result of the 13C-UBT. Conclusions: After partial gastrectomy, a discordant result was shown in the positive 13C-UBT results compared to the endoscopic biopsy methods for confirming the H. pylori status after eradication. Additional endoscopic biopsy-based H. pylori tests would be helpful to avoid unnecessary treatment for H. pylori eradication in these cases. PMID:25574466

  9. Sentinel lymph node mapping in melanoma: the issue of false-negative findings.

    PubMed

    Manca, Gianpiero; Rubello, Domenico; Romanini, Antonella; Boni, Giuseppe; Chiacchio, Serena; Tredici, Manuel; Mazzarri, Sara; Duce, Valerio; Colletti, Patrick M; Volterrani, Duccio; Mariani, Giuliano

    2014-07-01

    Management of cutaneous melanoma has changed after introduction in the clinical routine of sentinel lymph node biopsy (SLNB) for nodal staging. By defining the nodal basin status, SLNB provides a powerful prognostic information. Nevertheless, some debate still surrounds the accuracy of this procedure in terms of false-negative rate. Several large-scale studies have reported a relatively high false-negative rate (5.6%-21%), correctly defined as the proportion of false-negative results with respect to the total number of "actual" positive lymph nodes. In this review, we identified all the technical aspects that the nuclear medicine physician, the surgeon, and the pathologist should take into account to improve accuracy of the procedure and minimize the false-negative rate. In particular, SPECT/CT imaging detects more SLNs than those found by planar lymphoscintigraphy. Furthermore, the nuclear medicine community should reach a consensus on the radioactive counting rate threshold to better guide the surgeon in identifying the lymph nodes with the highest likelihood of housing metastases ("true biologic SLNs"). Analysis of the harvested SLNs by conventional techniques is also a further potential source for error. More accurate SLN analysis (eg, molecular analysis by reverse transcriptase-polymerase chain reaction) and more extensive SLN sampling identify more positive nodes, thus reducing the false-negative rate.The clinical factors identifying patients at higher-risk local recurrence after a negative SLNB include older age at diagnosis, deeper lesions, histological ulceration, and head-neck anatomic location of the primary lesion.The clinical impact of a false-negative SLNB on the prognosis of melanoma patients remains controversial, because the majority of studies have failed to demonstrate overall statistically significant disadvantage in melanoma-specific survival for false-negative SLNB patients compared with true-positive SLNB patients.When new more effective drugs will be available in the adjuvant setting for stage III melanoma patients, the implication of an accurate staging procedure for the sentinel lymph nodes will be crucial for both patients and clinicians. Standardization and accuracy of SLN identification, removal, and analysis are required.

  10. Evaluation of inadequate, indeterminate, false-negative and false-positive cases in cytological examination for breast cancer according to histological type

    PubMed Central

    2012-01-01

    Background We previously investigated the current status of breast cytology cancer screening at seven institutes in our area of southern Fukuoka Prefecture, and found some differences in diagnostic accuracy among the institutions. In the present study, we evaluated the cases involved and noted possible reasons for their original cytological classification as inadequate, indeterminate, false-negative and false-positive according to histological type. Methods We evaluated the histological findings in 5693 individuals who underwent cytological examination for breast cancer (including inadequate, indeterminate, false-negative and false-positive cases), to determine the most common histological types and/or features in these settings and the usefulness/limitations of cytological examination for the diagnosis of breast cancer. Results Among 1152 cytologically inadequate cases, histology revealed that 75/173 (43.6%) cases were benign, including mastopathy (fibrocystic disease) in 38.6%, fibroadenoma in 24.0% and papilloma in 5.3%. Ninety-five of 173 (54.9%) cases were histologically malignant, with scirrhous growing type, invasive ductal carcinoma (SIDC) being significantly more frequent (49.5%) than papillotubular growing type (Papi-tub) (P < 0.0001), solid-tubular growing type (P = 0.0001) and ductal carcinoma in situ (DCIS) (P = 0.0001). Among 458 indeterminate cases, 54/139 (38.8%) were histologically benign (mastopathy, 30.0%; fibroadenoma, 27.8%; papilloma, 26.0%) and 73/139 (52.5%) were malignant, with SIDC being the most frequent malignant tumor (37.0%). Among 52 false-negative cases, SIDC was significantly more frequent (42.3%) than DCIS (P = 0.0049) and Papi-tub (P = 0.001). There were three false-positive cases, with one each of fibroadenoma, epidermal cyst and papilloma. Conclusions The inadequate, indeterminate, false-negative and false-positive cases showed similar histological types, notably SIDC for malignant tumors, and mastopathy, fibroadenoma and papilloma for benign cases. We need to pay particular attention to the collection and assessment of aspirates for these histological types of breast disease. In particular, several inadequate, indeterminate and false-negative cases with samples collected by aspiration were diagnosed as SIDC. These findings should encourage the use of needle biopsy rather than aspiration when this histological type is identified on imaging. Namely, good communication between clinicians and pathological staff, and triple assessment (i.e., clinical, pathological and radiological assessment), are important for accurate diagnosis of aspiration samples. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/7349809170055423 PMID:22607447

  11. [Analysis for Discordance of Positive and Negative Blood Typing by Gel Card].

    PubMed

    Li, Cui-Ying; Xu, Hong; Lei, Hui-Fen; Liu, Juan; Li, Xiao-Wei

    2017-08-01

    To explore the method of Gel card identifying ABO blood group, determine the inconsistent cause and the distribution of disease affecting factors, and put forward a method of its solutions. To collect 240 positive and negative typing-discordant blood speciments from patients examined by Gel card and send these speciments to blood type reference laboratory for examining with the classic tube method and serological test, such as salivary blood-group substance, in order to performe genotyping method when serologic test can not be determined. Among 240 positive and negative typing-discordant blood speciments from patients examined by Gel card, 107 blood speciments were positive and negative consistent examined by false agglutination test (44.58%), 133 blood specinents were discordent examined by false agglutination (55.42%), out of them, 35 cases (14.58%) with inconsistent cold agglutination test, 22 cases (9.17%) with weakened AB antigenicity, 16 cases (6.67%) with ABO subtyping, 12 cases (5.00%) with positive direct antiglobulin test, 11 cases (4.58%) with reduced or without antibodies, 11 cases (4.58%) with false aggregation caused by drugs or protein, 11 cases (4.58%) with salivary blood-type substances, 8 cases (3.33%) with non-ABO alloantibody, and 7 cases (2.92%) with allogeneic bone marrow transplantation. The distribution of disease were following: blood disease (16.83%), tumor (11.88%), and cardiopulmonary diseases (11.39%); chi-square test results indicated that the distribution significantly different. The analysis of ABO blood grouping shows a variety factors influencing positive and negative blood typing, and the Gel Card identification can produc more false positive blood types. Therefore, more attention should be paid on the high incidence diseases, such as blood disease, tumor, and cardiopulmonary disease.

  12. Effect of obesity on preterm delivery prediction by transabdominal recording of uterine electromyography.

    PubMed

    Lucovnik, Miha; Chambliss, Linda R; Blumrick, Richard; Balducci, James; Gersak, Ksenija; Garfield, Robert E

    2016-10-01

    It has been shown that noninvasive uterine electromyography (EMG) can identify true preterm labor more accurately than methods available to clinicians today. The objective of this study was to evaluate the effect of body mass index (BMI) on the accuracy of uterine EMG in predicting preterm delivery. Predictive values of uterine EMG for preterm delivery were compared in obese versus overweight/normal BMI patients. Hanley-McNeil test was used to compare receiver operator characteristics curves in these groups. Previously reported EMG cutoffs were used to determine groups with false positive/false negative and true positive/true negative EMG results. BMI in these groups was compared with Student t test (p < 0.05 significant). A total of 88 patients were included: 20 obese, 64 overweight, and four with normal BMI. EMG predicted preterm delivery within 7 days with area under the curve = 0.95 in the normal/overweight group, and with area under the curve = 1.00 in the obese group (p = 0.08). Six patients in true preterm labor (delivering within 7 days from EMG measurement) had low EMG values (false negative group). There were no false positive results. No significant differences in patient's BMI were noted between false negative group patients and preterm labor patients with high EMG values (true positive group) and nonlabor patients with low EMG values (true negative group; p = 0.32). Accuracy of noninvasive uterine EMG monitoring and its predictive value for preterm delivery are not affected by obesity. Copyright © 2016. Published by Elsevier B.V.

  13. Emotion and false memory: How goal-irrelevance can be relevant for what people remember.

    PubMed

    Van Damme, Ilse; Kaplan, Robin L; Levine, Linda J; Loftus, Elizabeth F

    2017-02-01

    Elaborating on misleading information concerning emotional events can lead people to form false memories. The present experiment compared participants' susceptibility to false memories when they elaborated on information associated with positive versus negative emotion and pregoal versus postgoal emotion. Pregoal emotion reflects appraisals that goal attainment or failure is anticipated but has not yet occurred (e.g., hope and fear). Postgoal emotion reflects appraisals that goal attainment or failure has already occurred (e.g., happiness and devastation). Participants watched a slideshow depicting an interaction between a couple and were asked to empathise with the protagonist's feelings of hope (positive pregoal), happiness (positive postgoal), fear (negative pregoal), or devastation (negative postgoal); in control conditions, no emotion was mentioned. Participants were then asked to reflect on details of the interaction that had occurred (true) or had not occurred (false), and that were relevant or irrelevant to the protagonist's goal. Irrespective of emotional valence, participants in the pregoal conditions were more susceptible to false memories concerning goal-irrelevant details than were participants in the other conditions. These findings support the view that pregoal emotions narrow attention to information relevant to goal pursuit, increasing susceptibility to false memories for irrelevant information.

  14. Predicting the carcinogenicity of chemicals with alternative approaches: recent advances.

    PubMed

    Benigni, Romualdo

    2014-09-01

    Alternative approaches to the rodent bioassay are necessary for early identification of problematic drugs and biocides during the development process, and are the only practicable tool for assessing environmental chemicals with no or adequate safety documentation. This review informs on: i) the traditional prescreening through genotoxicity testing; ii) an integrative approach that assesses DNA-reactivity and ability to disorganize tissues; iii) new applications of omics technologies (ToxCast/Tox21 project); iv) a pragmatic approach aimed at filling data gaps by intrapolating/extrapolating from similar chemicals (read-across, category formation). The review also approaches the issue of the concerns about false-positive and false-negative results that prevents a wider acceptance and use of alternatives. The review addresses strengths and limitations of various proposals, and concludes on the need of differential approaches to the issue of false negatives and false positives. False negatives can be eliminated or reduced below the variability of the animal assay with conservative quantitative structure-activity relationships or in vitro tests; false positives can be cleared with ad hoc mechanistically based follow-ups. This framework can permit a reduction of animal testing and a better protection of human health.

  15. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    PubMed

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  16. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    PubMed Central

    2012-01-01

    Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals. PMID:22429706

  17. Risk of breast cancer after false-positive results in mammographic screening.

    PubMed

    Román, Marta; Castells, Xavier; Hofvind, Solveig; von Euler-Chelpin, My

    2016-06-01

    Women with false-positive results are commonly referred back to routine screening. Questions remain regarding their long-term outcome of breast cancer. We assessed the risk of screen-detected breast cancer in women with false-positive results. We conducted a joint analysis using individual level data from the population-based screening programs in Copenhagen and Funen in Denmark, Norway, and Spain. Overall, 150,383 screened women from Denmark (1991-2008), 612,138 from Norway (1996-2010), and 1,172,572 from Spain (1990-2006) were included. Poisson regression was used to estimate the relative risk (RR) of screen-detected cancer for women with false-positive versus negative results. We analyzed information from 1,935,093 women 50-69 years who underwent 6,094,515 screening exams. During an average 5.8 years of follow-up, 230,609 (11.9%) women received a false-positive result and 27,849 (1.4%) were diagnosed with screen-detected cancer. The adjusted RR of screen-detected cancer after a false-positive result was 2.01 (95% CI: 1.93-2.09). Women who tested false-positive at first screen had a RR of 1.86 (95% CI: 1.77-1.96), whereas those who tested false-positive at third screening had a RR of 2.42 (95% CI: 2.21-2.64). The RR of breast cancer at the screening test after the false-positive result was 3.95 (95% CI: 3.71-4.21), whereas it decreased to 1.25 (95% CI: 1.17-1.34) three or more screens after the false-positive result. Women with false-positive results had a twofold risk of screen-detected breast cancer compared to women with negative tests. The risk remained significantly higher three or more screens after the false-positive result. The increased risk should be considered when discussing stratified screening strategies. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  18. Verification of false-positive blood culture results generated by the BACTEC 9000 series by eubacterial 16S rDNA and panfungal 18S rDNA directed polymerase chain reaction (PCR).

    PubMed

    Daxboeck, Florian; Dornbusch, Hans Jürgen; Krause, Robert; Assadian, Ojan; Wenisch, Christoph

    2004-01-01

    A small but significant proportion of blood cultures processed by the BACTEC 9000 series systems is signaled positive, while subsequent Gram's stain and culture on solid media yield no pathogens. In this study, 15 "false-positive" vials (7 aerobes, 8 anaerobes) from 15 patients were investigated for the presence of bacteria and fungi by eubacterial 16S rDNA and panfungal 18S rDNA amplification, respectively. All samples turned out negative by both methods. Most patients (7) had neutropenia, which does not support the theory that high leukocyte counts enhance the generation of false-positive results. In conclusion, the results of this study indicate that false-negative results generated by the BACTEC 9000 series are inherent to the automated detection and not due to the growth of fastidious organisms.

  19. The diagnostic significance of lactate dehydrogenase isoenzymes in urinary cytology.

    PubMed Central

    Nishikawa, A.; Tanaka, T.; Takeuchi, T.; Fujihiro, S.; Mori, H.

    1991-01-01

    Lactate dehydrogenase (LDH) isoenzyme distribution was examined in 106 urine samples being tested cytologically for evidence of bladder cancer; the samples were selected to have less than 20 leucocytes and erythrocytes per high power field and the LDH pattern determined by electrophoresis. The Papanicolaou stained-smears showed 68 negative, 17 suspicious and 21 positive. The LDH M-fraction of the urinary supernatant in cytologically positive cases was significantly greater than in negative cases, although the latter included a few false negative samples. Some of the false negatives gave positive results for the LDH M-fraction; these results suggest that the determination of LDH isoenzymes in the urine is useful in diagnosing urinary tract cancers, including early stage, and for follow-up of patients with bladder cancers after surgical resection. PMID:2039708

  20. False-positive findings in Cochrane meta-analyses with and without application of trial sequential analysis: an empirical review.

    PubMed

    Imberger, Georgina; Thorlund, Kristian; Gluud, Christian; Wetterslev, Jørn

    2016-08-12

    Many published meta-analyses are underpowered. We explored the role of trial sequential analysis (TSA) in assessing the reliability of conclusions in underpowered meta-analyses. We screened The Cochrane Database of Systematic Reviews and selected 100 meta-analyses with a binary outcome, a negative result and sufficient power. We defined a negative result as one where the 95% CI for the effect included 1.00, a positive result as one where the 95% CI did not include 1.00, and sufficient power as the required information size for 80% power, 5% type 1 error, relative risk reduction of 10% or number needed to treat of 100, and control event proportion and heterogeneity taken from the included studies. We re-conducted the meta-analyses, using conventional cumulative techniques, to measure how many false positives would have occurred if these meta-analyses had been updated after each new trial. For each false positive, we performed TSA, using three different approaches. We screened 4736 systematic reviews to find 100 meta-analyses that fulfilled our inclusion criteria. Using conventional cumulative meta-analysis, false positives were present in seven of the meta-analyses (7%, 95% CI 3% to 14%), occurring more than once in three. The total number of false positives was 14 and TSA prevented 13 of these (93%, 95% CI 68% to 98%). In a post hoc analysis, we found that Cochrane meta-analyses that are negative are 1.67 times more likely to be updated (95% CI 0.92 to 2.68) than those that are positive. We found false positives in 7% (95% CI 3% to 14%) of the included meta-analyses. Owing to limitations of external validity and to the decreased likelihood of updating positive meta-analyses, the true proportion of false positives in meta-analysis is probably higher. TSA prevented 93% of the false positives (95% CI 68% to 98%). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Chronic bacterial osteomyelitis: prospective comparison of (18)F-FDG imaging with a dual-head coincidence camera and (111)In-labelled autologous leucocyte scintigraphy.

    PubMed

    Meller, J; Köster, G; Liersch, T; Siefker, U; Lehmann, K; Meyer, I; Schreiber, K; Altenvoerde, G; Becker, W

    2002-01-01

    Indium-111-labelled white blood cells ((111)In-WBCs) are currently considered the tracer of choice in the diagnostic work-up of suspected active chronic osteomyelitis (COM). Previous studies in a limited number of patients, performed with dedicated PET systems, have shown that [(18)F]2'-deoxy-2-fluoro- D-glucose (FDG) imaging may offer at least similar diagnostic accuracy. The aim of this prospective study was to compare FDG imaging with a dual-head coincidence camera (DHCC) and (111)In-WBC imaging in patients with suspected COM. Thirty consecutive non-diabetic patients with possible COM underwent combined skeletal scintigraphy (30/30 patients), (111)In-WBC imaging (28/30 patients) and FDG-PET with a DHCC (30/30 patients). During diagnostic work-up, COM was proven in 11/36 regions of suspected skeletal infection and subsequently excluded in 25/36 regions. In addition, soft tissue infection was present in five patients and septic arthritis in three. (111)In-WBC imaging in 28 patients was true positive in 2/11 regions with proven COM and true negative in 21/23 regions without further evidence of COM. False-positive results occurred in two regions and false-negative results in nine regions suspected for COM. Most of the false-negative results (7/9) occurred in the central skeleton. If the analysis was restricted to the 18 regions with available histology ( n=17) or culture ( n=1), (111)In-WBC imaging was true positive in 2/18 regions, true negative in 8/18 regions, false negative in 7/18 regions and false positive in 1/18 regions. FDG-DHCC imaging was true positive in 11/11 regions with proven COM and true negative in 23/25 regions without further evidence of COM. False-positive results occurred in two regions. If the analysis was restricted to the 19 regions with available histology ( n=18) or culture ( n=1), FDG-DHCC imaging was true positive in 9/9 regions with proven COM and true negative in 10/10 regions without further evidence of COM. It is concluded that FDG-DHCC imaging is superior to (111)In-WBC scintigraphy in the diagnosis of COM in the central skeleton and therefore should be considered the method of choice for this indication. This seems to hold true for peripheral lesions as well, but in our series the number of cases with proven infection was too small to permit a final conclusion.

  2. Frequency of false positive rapid HIV serologic tests in African men and women receiving PrEP for HIV prevention: implications for programmatic roll-out of biomedical interventions.

    PubMed

    Ndase, Patrick; Celum, Connie; Kidoguchi, Lara; Ronald, Allan; Fife, Kenneth H; Bukusi, Elizabeth; Donnell, Deborah; Baeten, Jared M

    2015-01-01

    Rapid HIV assays are the mainstay of HIV testing globally. Delivery of effective biomedical HIV prevention strategies such as antiretroviral pre-exposure prophylaxis (PrEP) requires periodic HIV testing. Because rapid tests have high (>95%) but imperfect specificity, they are expected to generate some false positive results. We assessed the frequency of true and false positive rapid results in the Partners PrEP Study, a randomized, placebo-controlled trial of PrEP. HIV testing was performed monthly using 2 rapid tests done in parallel with HIV enzyme immunoassay (EIA) confirmation following all positive rapid tests. A total of 99,009 monthly HIV tests were performed; 98,743 (99.7%) were dual-rapid HIV negative. Of the 266 visits with ≥1 positive rapid result, 99 (37.2%) had confirmatory positive EIA results (true positives), 155 (58.3%) had negative EIA results (false positives), and 12 (4.5%) had discordant EIA results. In the active PrEP arms, over two-thirds of visits with positive rapid test results were false positive results (69.2%, 110 of 159), although false positive results occurred at <1% (110/65,945) of total visits. When HIV prevalence or incidence is low due to effective HIV prevention interventions, rapid HIV tests result in a high number of false relative to true positive results, although the absolute number of false results will be low. Program roll-out for effective interventions should plan for quality assurance of HIV testing, mechanisms for confirmatory HIV testing, and counseling strategies for persons with positive rapid test results.

  3. False-positive cryptococcal antigen latex agglutination caused by disinfectants and soaps.

    PubMed Central

    Blevins, L B; Fenn, J; Segal, H; Newcomb-Gayman, P; Carroll, K C

    1995-01-01

    Five disinfectants or soaps were tested to determine if any could be responsible for false-positive results obtained with the Latex-Crypto Antigen Detection System kit (Immuno-Mycologics, Inc., Norman, Okla.). Three disinfectants or soaps (Derma soap, 7X, and Bacdown) produced false-positive agglutination after repeated washing of ring slides during testing of a known negative cerebrospinal fluid specimen. PMID:7650214

  4. Extended focused assessment with sonography for trauma (EFAST) in the diagnosis of pneumothorax: experience at a community based level I trauma center.

    PubMed

    Nandipati, Kalyana C; Allamaneni, Shyam; Kakarla, Ravindra; Wong, Alfredo; Richards, Neil; Satterfield, James; Turner, James W; Sung, Kae-Jae

    2011-05-01

    Early identification of pneumothorax is crucial to reduce the mortality in critically injured patients. The objective of our study is to investigate the utility of surgeon performed extended focused assessment with sonography for trauma (EFAST) in the diagnosis of pneumothorax. We prospectively analysed 204 trauma patients in our level I trauma center over a period of 12 (06/2007-05/2008) months in whom EFAST was performed. The patients' demographics, type of injury, clinical examination findings (decreased air entry), CXR, EFAST and CT scan findings were entered into the data base. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated. Of 204 patients (mean age--43.01+/-19.5 years, sex--male 152, female 52) 21 (10.3%) patients had pneumothorax. Of 21 patients who had pneumothorax 12 were due to blunt trauma and 9 were due to penetrating trauma. The diagnosis of pneumothorax in 204 patients demonstrated the following: clinical examination was positive in 17 patients (true positive in 13/21, 62%; 4 were false positive and 8 were false negative), CXR was positive in 16 (true positive in 15/19, 79%; 1 false positive, 4 missed and 2 CXR not performed before chest tube) patients and EFAST was positive in 21 patients (20 were true positive [95.2%], 1 false positive and 1 false negative). In diagnosing pneumothorax EFAST has significantly higher sensitivity compared to the CXR (P=0.02). Surgeon performed trauma room extended FAST is simple and has higher sensitivity compared to the chest X-ray and clinical examination in detecting pneumothorax. Published by Elsevier Ltd.

  5. Can integrated 18F-FDG PET/MR replace sentinel lymph node resection in malignant melanoma?

    PubMed

    Schaarschmidt, Benedikt Michael; Grueneisen, Johannes; Stebner, Vanessa; Klode, Joachim; Stoffels, Ingo; Umutlu, Lale; Schadendorf, Dirk; Heusch, Philipp; Antoch, Gerald; Pöppel, Thorsten Dirk

    2018-06-06

    To compare the sensitivity and specificity of 18F-fluordesoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT), 18F-FDG PET/magnetic resonance (18F-FDG PET/MR) and 18F-FDG PET/MR including diffusion weighted imaging (DWI) in the detection of sentinel lymph node metastases in patients suffering from malignant melanoma. Fifty-two patients with malignant melanoma (female: n = 30, male: n = 22, mean age 50.5 ± 16.0 years, mean tumor thickness 2.28 ± 1.97 mm) who underwent 18F-FDG PET/CT and subsequent PET/MR & DWI for distant metastasis staging were included in this retrospective study. After hybrid imaging, lymphoscintigraphy including single photon emission computed tomography/CT (SPECT/CT) was performed to identify the sentinel lymph node prior to sentinel lymph node biopsy (SLNB). In a total of 87 sentinel lymph nodes in 64 lymph node basins visible on SPECT/CT, 17 lymph node metastases were detected by histopathology. In separate sessions PET/CT, PET/MR, and PET/MR & DWI were assessed for sentinel lymph node metastases by two independent readers. Discrepant results were resolved in a consensus reading. Sensitivities, specificities, positive predictive values and negative predictive values were calculated with histopathology following SPECT/CT guided SLNB as a reference standard. Compared with histopathology, lymph nodes were true positive in three cases, true negative in 65 cases, false positive in three cases and false negative in 14 cases in PET/CT. PET/MR was true positive in four cases, true negative in 63 cases, false positive in two cases and false negative in 13 cases. Hence, we observed a sensitivity, specificity, positive predictive value and negative predictive value of 17.7, 95.6, 50.0 and 82.3% for PET/CT and 23.5, 96.9, 66.7 and 82.3% for PET/MR. In DWI, 56 sentinel lymph node basins could be analyzed. Here, the additional analysis of DWI led to two additional false positive findings, while the number of true positive findings could not be increased. In conclusion, integrated 18F-FDG PET/MR does not reliably differentiate N-positive from N-negative melanoma patients. Additional DWI does not increase the sensitivity of 18F-FDG PET/MR. Hence, sentinel lymph node biopsy cannot be replaced by 18F-FDG-PE/MR or 18F-FDG-PET/CT.

  6. False-positive cancer screens and health-related quality of life.

    PubMed

    McGovern, Patricia M; Gross, Cynthia R; Krueger, Richard A; Engelhard, Deborah A; Cordes, Jill E; Church, Timothy R

    2004-01-01

    By design, screening tests are imperfect-unresponsive to some cancers (false negatives) while occasionally raising suspicion of cancer where none exists (false positives). This pilot study describes patients' responses to having a false-positive screening test for cancer, and identifies screening effects on health-related quality of life (HRQoL). The pilot findings suggest issues important for incorporation in future evaluations of the impact of screening for prostate, lung, colon, or ovarian (PLCO) cancers. Seven focus groups were conducted to identify the nature and meaning of all phases of PLCO screening. Minnesota participants in the Prostate, Lung, Colorectal and Ovarian Cancer Screening Trial who had completed screening, with at least 1 false-positive screen, participated (N = 47). Participants' reactions to abnormal screens and diagnostic work-ups were primarily emotional (eg, anxiety and distress), not physical, and ultimately positive for the majority. Health distress and fear of cancer and death were the major negative aspects of HRQoL identified. These concepts are not typically included in generic HRQoL questionnaires like the SF-36, but are highly relevant to PLCO screening. Clinicians were regarded as underestimating the discomfort of follow-up diagnostic testing. However, relief and assurance appeared to eventually outweigh the negative emotions for most participants. Implications for oncology nurses include the need to consider the emotional consequences of screening in association with screen reliability and validity.

  7. Performance assessment of the Capilia TB assay and the BD ProbeTec ET system for rapid culture confirmation of Mycobacterium tuberculosis.

    PubMed

    Wang, Jann-Yuan; Lee, Li-Na; Lai, Hsin-Chih; Hsu, Hsiao-Leng; Jan, I-Shiow; Yu, Chong-Jen; Hsueh, Po-Ren; Yang, Pan-Chyr

    2007-12-01

    Because of the increasing numbers of nontuberculous mycobacterial isolates from clinical specimens, rapid and accurate methods for culture confirmation of Mycobacterium tuberculosis are urgently needed. The study evaluated the performance of the Capilia TB immunochromatographic assay (TAUNS, Numazu, Japan) for culture confirmation of M. tuberculosis using 242 culture-positive liquid media in 2 mycobacterial laboratories from November 2005 to February 2006. Among the 242 samples, 183 were also tested with the BD ProbeTec ET (CTB) assay (Becton Dickinson, Sparks, MD). The results of both assays were compared to the culture results and to each other. The overall sensitivity and specificity of the Capilia TB assay were 98.6% and 97.9%, respectively, and for the CTB assay were 97.3% and 97.1%, respectively. The positive and negative predictive values for the Capilia TB assay were 98.6% and 97.9%, respectively, and for the CTB assay were 98.2% and 95.8%, respectively. Among the 183 samples tested with both assays, 8 had discrepant results, including Capilia-TB-false-positive in 2, CTB-false-positive in another 2, CTB-false-negative in 2, Capilia TB-false-negative in 1, and both assays with false-negative results in the remaining one. This study demonstrated that the Capilia TB assay has a similar diagnostic value with the CTB assay. In addition, with the immunochromatographic method, it is less time-consuming and does not require other laboratory equipment.

  8. False feedback and beliefs influence name recall in younger and older adults.

    PubMed

    Strickland-Hughes, Carla M; West, Robin Lea; Smith, Kimberly A; Ebner, Natalie C

    2017-09-01

    Feedback is an important self-regulatory process that affects task effort and subsequent performance. Benefits of positive feedback for list recall have been explored in research on goals and feedback, but the effect of negative feedback on memory has rarely been studied. The current research extends knowledge of memory and feedback effects by investigating face-name association memory and by examining the potential mediation of feedback effects, in younger and older adults, through self-evaluative beliefs. Beliefs were assessed before and after name recognition and name recall testing. Repeated presentation of false positive feedback was compared to false negative feedback and a no feedback condition. Results showed that memory self-efficacy declined over time for participants in the negative and no feedback conditions but was sustained for those receiving positive feedback. Furthermore, participants who received negative feedback felt older after testing than before testing. For name recall, the positive feedback group outperformed the negative feedback and no feedback groups combined, with no age interactions. The observed feedback-related effects on memory were fully mediated by changes in memory self-efficacy. These findings advance our understanding of how beliefs are related to feedback in memory and inform future studies examining the importance of self-regulation in memory.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dana Kelly; Kurt Vedros; Robert Youngblood

    This paper examines false indication probabilities in the context of the Mitigating System Performance Index (MSPI), in order to investigate the pros and cons of different approaches to resolving two coupled issues: (1) sensitivity to the prior distribution used in calculating the Bayesian-corrected unreliability contribution to the MSPI, and (2) whether (in a particular plant configuration) to model the fuel oil transfer pump (FOTP) as a separate component, or integrally to its emergency diesel generator (EDG). False indication probabilities were calculated for the following situations: (1) all component reliability parameters at their baseline values, so that the true indication ismore » green, meaning that an indication of white or above would be false positive; (2) one or more components degraded to the extent that the true indication would be (mid) white, and “false” would be green (negative) or yellow (negative) or red (negative). In key respects, this was the approach taken in NUREG-1753. The prior distributions examined were the constrained noninformative (CNI) prior used currently by the MSPI, a mixture of conjugate priors, the Jeffreys noninformative prior, a nonconjugate log(istic)-normal prior, and the minimally informative prior investigated in (Kelly et al., 2010). The mid-white performance state was set at ?CDF = ?10 ? 10-6/yr. For each simulated time history, a check is made of whether the calculated ?CDF is above or below 10-6/yr. If the parameters were at their baseline values, and ?CDF > 10-6/yr, this is counted as a false positive. Conversely, if one or all of the parameters are set to values corresponding to ?CDF > 10-6/yr but that time history’s ?CDF < 10-6/yr, this is counted as a false negative indication. The false indication (positive or negative) probability is then estimated as the number of false positive or negative counts divided by the number of time histories (100,000). Results are presented for a set of base case parameter values, and three sensitivity cases in which the number of FOTP demands was reduced, along with the Birnbaum importance of the FOTP.« less

  10. The Diagnostic Validity of Citric Acid-Free, High Dose (13)C-Urea Breath Test After Helicobacter pylori Eradication in Korea.

    PubMed

    Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Hwang, Jae Jin; Lee, Hyun Joo; Lee, AeRa; Jeong, Yeon Sang; Oh, Sooyeon; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho

    2015-06-01

    The (13)C-urea breath test ((13)C-UBT) is a noninvasive method for diagnosing Helicobacter pylori (H. pylori) infection. The aims of this study were to evaluate the diagnostic validity of the (13)C-UBT cutoff value and to identify influencing clinical factors responsible for aberrant results. (13)C-UBT (UBiTkit; Otsuka Pharmaceutical, cutoff value: 2.5‰) results in the range 2.0‰ to 10.0‰ after H. pylori eradication therapy were compared with the results of endoscopic biopsy results of the antrum and body. Factors considered to affect test results adversely were analyzed. Among patients with a positive (13)C-UBT result (2.5‰ to 10.0‰, n = 223) or a negative (13)C-UBT result (2.0‰ to < 2.5‰, n = 66) after H. pylori eradication, 73 patients (34.0%) were false positive, and one (1.5%) was false negative as determined by endoscopic biopsy. The sensitivity, specificity, false-positive rate, and false-negative rate for a cutoff value of 2.5‰ were 99.3%, 47.1%, 52.9%, and 0.7%, respectively, and positive and negative predictive values of the (13)C-UBT were 67.3% and 98.5%, respectively. Multivariate analysis showed that a history of two or more previous H. pylori eradication therapies (OR = 2.455, 95%CI = 1.299-4.641) and moderate to severe gastric intestinal metaplasia (OR = 3.359, 95%CI = 1.572-7.178) were associated with a false-positive (13)C-UBT result. The (13)C-UBT cutoff value currently used has poor specificity for confirming H. pylori status after eradication, and this lack of specificity is exacerbated in patients that have undergone multiple prior eradication therapies and in patients with moderate to severe gastric intestinal metaplasia. In addition, the citric-free (13)C-UBT would increase a false-positive (13)C-UBT result. © 2015 John Wiley & Sons Ltd.

  11. Prolactin as a Marker of Successful Catheterization during IPSS in Patients with ACTH-Dependent Cushing's Syndrome

    PubMed Central

    Sharma, S. T.; Raff, H.

    2011-01-01

    Context: Anomalous venous drainage can lead to false-negative inferior petrosal sinus sampling (IPSS) results. Baseline inferior petrosal sinus to peripheral (IPS/P) prolactin ratio higher than 1.8 ipsilateral to the highest ACTH ratio has been proposed to verify successful catheterization. Prolactin-normalized ACTH IPS/P ratios may differentiate Cushing's disease (CD) from ectopic ACTH syndrome (EAS). Objective: Our objective was to examine the utility of prolactin measurement during IPSS. Design, Setting, and Participants: We conducted a retrospective analysis of prolactin levels in basal and CRH-stimulated IPSS samples in ACTH-dependent Cushing's syndrome (2007–2010). Results: Twenty-five of 29 patients had a pathologically proven diagnosis (17 CD and eight EAS). IPSS results were partitioned into true positive for CD (n = 16), true negative (n = 7), false negative (n = 1), and false positive (n = 1). Prolactin IPS/P ratio suggested successful IPSS in eight of 11 with abnormal venograms. Baseline prolactin IPS/P ratio was helpful in two patients with abnormal venograms and false-negative (catheterization unsuccessful) or true-negative (catheterization successful) IPSS results; the normalized ratio correctly diagnosed their disease. Normalized ACTH IPS/P ratio was at least 1.3 in all with CD, but prolactin IPS/P ratios were misleadingly low in two. One patient with cyclic EAS had a false-positive IPSS when eucortisolemic (baseline prolactin IPS/P = 1.7; normalized ratio = 5.6). All other EAS patients had normalized ratios no higher than 0.7. Conclusion: Prolactin measurement and evaluation of the venogram can improve diagnostic accuracy when IPSS results suggest EAS but is not necessary with positive IPSS results. Confirmation of hypercortisolemia remains a prerequisite for IPSS. A normalized ratio of 0.7–1.3 was not diagnostic. PMID:22031511

  12. Quality control in molecular immunohistochemistry

    PubMed Central

    2008-01-01

    Immunoperoxidase histochemistry is a widespread method of assessing expression of biomolecules in tissue samples. Accurate assessment of the expression levels of genes is critical for the management of disease, particularly as therapy targeted to specific molecules becomes more widespread. Determining the quality of preservation of macromolecules in tissue is important to avoid false negative and false positive results. In this review we discuss (1) issues of sensitivity (false negativity) and specificity (false positivity) of immunohistochemical stains, (2) approaches to better understanding differences in immunostains done by different laboratories (including the recently proposed MISFISHIE specification for tissue localization studies), and (3) approaches to assessing the quality of preservation of macromolecules in tissue, particularly in small biopsy samples. PMID:18648842

  13. The Precautionary Principle and Electric and Magnetic Fields

    PubMed Central

    Jamieson, Dale; Wartenberg, Daniel

    2001-01-01

    Current environmental regulation represents a paternalistic policy, more concerned to avoid false positives than false negatives, limiting opportunities for individuals to make choices between risk-avoidance and risk-taking alternatives. For example, many exposures to magnetic fields could be reduced at little or no cost but are not considered seriously, owing to the uncertainty of risk and the concern to avoid false positives. Even though precautionary approaches that focus on avoiding false negatives often do not lead to adverse economic consequences or irrational choices, such approaches usually are not taken. The value of autonomy and the proper role of governmental paternalism with respect to environmental policy need to be considered more carefully in environmental decision making. PMID:11527754

  14. The health system impact of false positive newborn screening results for medium-chain acyl-CoA dehydrogenase deficiency: a cohort study.

    PubMed

    Karaceper, Maria D; Chakraborty, Pranesh; Coyle, Doug; Wilson, Kumanan; Kronick, Jonathan B; Hawken, Steven; Davies, Christine; Brownell, Marni; Dodds, Linda; Feigenbaum, Annette; Fell, Deshayne B; Grosse, Scott D; Guttmann, Astrid; Laberge, Anne-Marie; Mhanni, Aizeddin; Miller, Fiona A; Mitchell, John J; Nakhla, Meranda; Prasad, Chitra; Rockman-Greenberg, Cheryl; Sparkes, Rebecca; Wilson, Brenda J; Potter, Beth K

    2016-02-03

    There is no consensus in the literature regarding the impact of false positive newborn screening results on early health care utilization patterns. We evaluated the impact of false positive newborn screening results for medium-chain acyl-CoA dehydrogenase deficiency (MCADD) in a cohort of Ontario infants. The cohort included all children who received newborn screening in Ontario between April 1, 2006 and March 31, 2010. Newborn screening and diagnostic confirmation results were linked to province-wide health care administrative datasets covering physician visits, emergency department visits, and inpatient hospitalizations, to determine health service utilization from April 1, 2006 through March 31, 2012. Incidence rate ratios (IRRs) were used to compare those with false positive results for MCADD to those with negative newborn screening results, stratified by age at service use. We identified 43 infants with a false positive newborn screening result for MCADD during the study period. These infants experienced significantly higher rates of physician visits (IRR: 1.42) and hospitalizations (IRR: 2.32) in the first year of life relative to a screen negative cohort in adjusted analyses. Differences in health services use were not observed after the first year of life. The higher use of some health services among false positive infants during the first year of life may be explained by a psychosocial impact of false positive results on parental perceptions of infant health, and/or by differences in underlying health status. Understanding the impact of false positive newborn screening results can help to inform newborn screening programs in designing support and education for families. This is particularly important as additional disorders are added to expanded screening panels, yielding important clinical benefits for affected children but also a higher frequency of false positive findings.

  15. Implications of false-positive results for future cancer screenings.

    PubMed

    Taksler, Glen B; Keating, Nancy L; Rothberg, Michael B

    2018-06-01

    False-positive cancer screening results may affect a patient's willingness to obtain future screening. The authors conducted logistic regression analysis of 450,484 person-years of electronic medical records (2006-2015) in 92,405 individuals aged 50 to 75 years. Exposures were false-positive breast, prostate, or colorectal cancer screening test results (repeat breast imaging or negative breast biopsy ≤3 months after screening mammography, repeat prostate-specific antigen [PSA] test ≤3 months after PSA test result ≥4.0 ng/mL or negative prostate biopsy ≤3 months after any PSA result, or negative colonoscopy [without biopsy/polypectomy] ≤6 months after a positive fecal occult blood test). Outcomes were up-to-date status with breast or colorectal cancer screening. Covariates included prior screening history, clinical information (eg, family history, obesity, and smoking status), comorbidity, and demographics. Women were more likely to be up to date with breast cancer screening if they previously had false-positive mammography findings (adjusted odds ratio [AOR], 1.43 [95% confidence interval, 1.34-1.51] without breast biopsy and AOR, 2.02 [95% confidence interval, 1.56-2.62] with breast biopsy; both P<.001). The same women were more likely to be up to date with colorectal cancer screening (AOR range, 1.25-1.47 depending on breast biopsy; both P<.001). Men who previously had false-positive PSA testing were more likely to be up to date with colorectal cancer screening (AOR, 1.22 [P = .039] without prostate imaging/biopsy and AOR, 1.60 [P = .028] with imaging/biopsy). Results were stronger for individuals with more false-positive results (all P≤.005). However, women with previous false-positive colorectal cancer fecal occult blood test screening results were found to be less likely to be up to date with breast cancer screening (AOR, 0.73; P<.001). Patients who previously had a false-positive breast or prostate cancer screening test were more likely to engage in future screening. Cancer 2018;124:2390-8. © 2018 American Cancer Society. © 2018 American Cancer Society.

  16. Arousal-But Not Valence-Reduces False Memories at Retrieval.

    PubMed

    Mirandola, Chiara; Toffalini, Enrico

    2016-01-01

    Mood affects both memory accuracy and memory distortions. However, some aspects of this relation are still poorly understood: (1) whether valence and arousal equally affect false memory production, and (2) whether retrieval-related processes matter; the extant literature typically shows that mood influences memory performance when it is induced before encoding, leaving unsolved whether mood induced before retrieval also impacts memory. We examined how negative, positive, and neutral mood induced before retrieval affected inferential false memories and related subjective memory experiences. A recognition-memory paradigm for photographs depicting script-like events was employed. Results showed that individuals in both negative and positive moods-similar in arousal levels-correctly recognized more target events and endorsed fewer false memories (and these errors were linked to remember responses less frequently), compared to individuals in neutral mood. This suggests that arousal (but not valence) predicted memory performance; furthermore, we found that arousal ratings provided by participants were more adequate predictors of memory performance than their actual belonging to either positive, negative or neutral mood groups. These findings suggest that arousal has a primary role in affecting memory, and that mood exerts its power on true and false memory even when induced at retrieval.

  17. Arousal—But Not Valence—Reduces False Memories at Retrieval

    PubMed Central

    Mirandola, Chiara; Toffalini, Enrico

    2016-01-01

    Mood affects both memory accuracy and memory distortions. However, some aspects of this relation are still poorly understood: (1) whether valence and arousal equally affect false memory production, and (2) whether retrieval-related processes matter; the extant literature typically shows that mood influences memory performance when it is induced before encoding, leaving unsolved whether mood induced before retrieval also impacts memory. We examined how negative, positive, and neutral mood induced before retrieval affected inferential false memories and related subjective memory experiences. A recognition-memory paradigm for photographs depicting script-like events was employed. Results showed that individuals in both negative and positive moods–similar in arousal levels–correctly recognized more target events and endorsed fewer false memories (and these errors were linked to remember responses less frequently), compared to individuals in neutral mood. This suggests that arousal (but not valence) predicted memory performance; furthermore, we found that arousal ratings provided by participants were more adequate predictors of memory performance than their actual belonging to either positive, negative or neutral mood groups. These findings suggest that arousal has a primary role in affecting memory, and that mood exerts its power on true and false memory even when induced at retrieval. PMID:26938737

  18. Analysis of sentinel node positivity in primary cutaneous melanoma: an 8-year single institution experience.

    PubMed

    Joyce, K M; McInerney, N M; Piggott, R P; Martin, F; Jones, D M; Hussey, A J; Kerin, M J; Kelly, J L; Regan, P J

    2017-11-01

    Sentinel lymph node biopsy (SLNB) is a standard method for determining the pathologic status of the regional lymph nodes. The aim of our study was to determine the incidence and clinicopathologic factors predictive of SLN positivity, and to evaluate the prognostic importance of SLNB in patients with cutaneous melanoma. We performed a retrospective analysis of a prospectively maintained database of all patients who underwent SLNB for primary melanoma at our institution from 2005 to 2012. Statistical analysis was performed using χ 2 and Fischer exact test. In total, 318 patients underwent SLNB, of which 65 were for thin melanoma (≤1 mm). There were 36 positive SLNB, 278 negative SLNB and in four cases the SLN was not located. The incidence rate for SLNB was 11.3% overall and 1.5% in thin melanomas alone. Statistical analysis identified Breslow thickness >1 mm (P = 0.006), Clark level ≥ IV (P = 0.004) and age <75 years (P = 0.035) as the strongest predictors of SLN positivity. Our overall false negativity rate was 20% (9/45) with one case of false-negative SLNB in thin melanomas. Breslow thickness of the primary tumour remains the strongest predictor of SLN positivity. Our findings point to a possible limited role for SLNB in thin melanoma due to its low positivity rate, associated false-negative rate and related morbidity.

  19. Detection of right-to-left shunts: comparison between the International Consensus and Spencer Logarithmic Scale criteria.

    PubMed

    Lao, Annabelle Y; Sharma, Vijay K; Tsivgoulis, Georgios; Frey, James L; Malkoff, Marc D; Navarro, Jose C; Alexandrov, Andrei V

    2008-10-01

    International Consensus Criteria (ICC) consider right-to-left shunt (RLS) present when Transcranial Doppler (TCD) detects even one microbubble (microB). Spencer Logarithmic Scale (SLS) offers more grades of RLS with detection of >30 microB corresponding to a large shunt. We compared the yield of ICC and SLS in detection and quantification of a large RLS. We prospectively evaluated paradoxical embolism in consecutive patients with ischemic strokes or transient ischemic attack (TIA) using injections of 9 cc saline agitated with 1 cc of air. Results were classified according to ICC [negative (no microB), grade I (1-20 microB), grade II (>20 microB or "shower" appearance of microB), and grade III ("curtain" appearance of microB)] and SLS criteria [negative (no microB), grade I (1-10 microB), grade II (11-30 microB), grade III (31100 microB), grade IV (101300 microB), grade V (>300 microB)]. The RLS size was defined as large (>4 mm) using diameter measurement of the septal defects on transesophageal echocardiography (TEE). TCD comparison to TEE showed 24 true positive, 48 true negative, 4 false positive, and 2 false negative cases (sensitivity 92.3%, specificity 92.3%, positive predictive value (PPV) 85.7%, negative predictive value (NPV) 96%, and accuracy 92.3%) for any RLS presence. Both ICC and SLS were 100% sensitive for detection of large RLS. ICC and SLS criteria yielded a false positive rate of 24.4% and 7.7%, respectively when compared to TEE. Although both grading scales provide agreement as to any shunt presence, using the Spencer Scale grade III or higher can decrease by one-half the number of false positive TCD diagnoses to predict large RLS on TEE.

  20. Clinical significance of FDG-PET/CT at the postoperative surveillance in the breast cancer patients.

    PubMed

    Jung, Na Young; Yoo, Ie Ryung; Kang, Bong Joo; Kim, Sung Hun; Chae, Byung Joo; Seo, Ye Young

    2016-01-01

    We evaluated the clinical role of [(18)F]-2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (FDG-PET/CT) compared with conventional imaging (CI) to detect locoregional recurrence or distant metastasis during postoperative surveillance of patients with breast cancer. We included 1,819 examinations of 1,161 patients, who underwent FDG-PET/CT and CI, including mammography, breast ultrasound, whole-body bone scintigraphy, and chest radiography for postoperative surveillance. All patients had a history of surgery with or without adjuvant treatment due to more than stage II breast cancer between November 2003 and November 2009. We evaluated the diagnostic performance of CI, FDG-PET/CT, and combined CI and FDG-PET/CT for detecting locoregional recurrence, distant metastasis, and incidental cancer. We also analyzed false-positive and false-negative results in both FDG-PET/CT and CI. Sensitivity, specificity, positive predictive value, and negative predictive value of CI were 75.4, 98.7, 93.4, and 94.3 %. Those of FDG-PET/CT were 97.5, 98.8, 95.4, and 99.4 %. Those of the combined results were 98.6, 98.2, 96.7, and 99.7 %. Sensitivity of FDG-PET/CT was significantly higher than that of CI (P < 0.05). Sensitivity of combined CI and FDG-PET/CT results improved, but they were not significantly different from those of FDG-PET/CT alone (P = 0.43). Seventeen false-positive and nine false-negative cases were detected with FDG-PET/CT, and 19 false-positive and 88 false-negative cases were detected with CI. FDG-PET/CT is considered as an acceptable diagnostic imaging modality for postoperative surveillance of patients with breast cancer.

  1. The local lymph node assay: current position in the regulatory classification of skin sensitizing chemicals.

    PubMed

    Basketter, David A; Gerberick, G Frank; Kimber, Ian

    2007-01-01

    The local lymph node assay (LLNA) is being used increasingly in the identification of skin sensitizing chemicals for regulatory purposes. In the context of new chemicals legislation (REACH) in Europe, it is the preferred assay. The rationale for this is that the LLNA quantitative and objective approach to skin sensitization testing allied with the important animal welfare benefits that the method offers. However, as with certain guinea pig sensitization tests before it, this increasing use also brings experience with an increasingly wide range of industrial and other chemicals where the outcome of the assay does not always necessarily meet with the expectations of those conducting it. Sometimes, the result appears to be a false negative, but rather more commonly, the complaint is that the chemical represents a false positive. Against this background we have here reviewed a number of instances where false positive and false negative results have been described and have sought to reconcile science with expectation. Based on these analyses, it is our conclusion that false positives and false negatives do occur in the LLNA, as they do with any other skin sensitization assay (and indeed with all tests used for hazard identification), and that this occurs for a number of reasons. We further conclude, however, that false positive results in the LLNA, as with the guinea pig maximization test, arise most commonly via failure to distinguish what is scientifically correct from that which is unpalatable. The consequences of this confusion are discussed in the article, particularly in relation to the need to integrate both potency measurement and risk assessments into classification and labelling schemes that aim to manage potential risks to human health.

  2. Sample Selection for Training Cascade Detectors.

    PubMed

    Vállez, Noelia; Deniz, Oscar; Bueno, Gloria

    2015-01-01

    Automatic detection systems usually require large and representative training datasets in order to obtain good detection and false positive rates. Training datasets are such that the positive set has few samples and/or the negative set should represent anything except the object of interest. In this respect, the negative set typically contains orders of magnitude more images than the positive set. However, imbalanced training databases lead to biased classifiers. In this paper, we focus our attention on a negative sample selection method to properly balance the training data for cascade detectors. The method is based on the selection of the most informative false positive samples generated in one stage to feed the next stage. The results show that the proposed cascade detector with sample selection obtains on average better partial AUC and smaller standard deviation than the other compared cascade detectors.

  3. Fine-Needle Aspiration, Touch Imprint, and Crush Preparation Cytology for Diagnosing Thyroid Malignancies in Thyroid Nodules.

    PubMed

    Ahmadinejad, Mojtaba; Aliepour, Asghar; Anbari, Khatereh; Kaviani, Mojhgan; Ganjizadeh, Hasan; Nadri, Sedigheh; Foroutani, Niloufar; Meysami, Masoumeh; Almasi, Vahid

    2015-12-01

    Several methods are used to evaluate the thyroid nodules. The aim of this study was to determine the sensitivity, specificity, false positive and negative rates, positive predictive value (PPV), and negative predictive value (NPV) of touch imprint, crush preparation, and fine-needle aspiration (FNA) methods. This cross-sectional study was done in Shohada-ye Ashayer University Hospital in Khorramabad. All the patients who underwent thyroid surgery due to thyroid nodules in this hospital between March and September 2011 were evaluated. The thyroid nodules of all the patients were evaluated by touch imprint, crush preparation, FNA, and permanent pathology methods. Finally, the results of the first three methods were compared with the result of permanent pathology method. The mean age of 104 patients who underwent thyroid surgery was 42.6 ± 11.9 years old. Based on permanent pathology, touch imprint, crush preparation, and FNA methods, 15.3, 6.25, 6.25, and 4.4 % of thyroid nodules were malignant, respectively. Sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of FNA biopsy were 62.5, 100, 0, 37.5, 100, and 95.3 %, respectively. Also, sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of touch imprint and crush preparation were equal and were 80, 100, 0, 20, 100, and 96.7 %, respectively. Using touch imprint and crush preparation in evaluation of thyroid nodules for rapid evaluation of these nodules in operating rooms seems to be logical, and it can prevent further surgeries.

  4. Methods for threshold determination in multiplexed assays

    DOEpatents

    Tammero, Lance F. Bentley; Dzenitis, John M; Hindson, Benjamin J

    2014-06-24

    Methods for determination of threshold values of signatures comprised in an assay are described. Each signature enables detection of a target. The methods determine a probability density function of negative samples and a corresponding false positive rate curve. A false positive criterion is established and a threshold for that signature is determined as a point at which the false positive rate curve intersects the false positive criterion. A method for quantitative analysis and interpretation of assay results together with a method for determination of a desired limit of detection of a signature in an assay are also described.

  5. Biological false-positive venereal disease research laboratory test in cerebrospinal fluid in the diagnosis of neurosyphilis - a case-control study.

    PubMed

    Zheng, S; Lin, R J; Chan, Y H; Ngan, C C L

    2018-03-01

    There is no clear consensus on the diagnosis of neurosyphilis. The Venereal Disease Research Laboratory (VDRL) test from cerebrospinal fluid (CSF) has traditionally been considered the gold standard for diagnosing neurosyphilis but is widely known to be insensitive. In this study, we compared the clinical and laboratory characteristics of true-positive VDRL-CSF cases with biological false-positive VDRL-CSF cases. We retrospectively identified cases of true and false-positive VDRL-CSF across a 3-year period received by the Immunology and Serology Laboratory, Singapore General Hospital. A biological false-positive VDRL-CSF is defined as a reactive VDRL-CSF with a non-reactive Treponema pallidum particle agglutination (TPPA)-CSF and/or negative Line Immuno Assay (LIA)-CSF IgG. A true-positive VDRL-CSF is a reactive VDRL-CSF with a concordant reactive TPPA-CSF and/or positive LIA-CSF IgG. During the study period, a total of 1254 specimens underwent VDRL-CSF examination. Amongst these, 60 specimens from 53 patients tested positive for VDRL-CSF. Of the 53 patients, 42 (79.2%) were true-positive cases and 11 (20.8%) were false-positive cases. In our setting, a positive non-treponemal serology has 97.6% sensitivity, 100% specificity, 100% positive predictive value and 91.7% negative predictive value for a true-positive VDRL-CSF based on our laboratory definition. HIV seropositivity was an independent predictor of a true-positive VDRL-CSF. Biological false-positive VDRL-CSF is common in a setting where patients are tested without first establishing a serological diagnosis of syphilis. Serological testing should be performed prior to CSF evaluation for neurosyphilis. © 2017 European Academy of Dermatology and Venereology.

  6. Comparison of results for morphine urinalyses by radioimmunoassay and thin-layer chromatography in a narcotic clinic setting.

    PubMed

    Kokoski, R J; Jain, M

    1975-03-01

    Radioimmunoassay (RIA) and thin-layer chromatography (TLC) were compared for morphine detection in an actual narcotic clinic setting. A choice of urines from all those screened by TLC allowed a critical comparison as to actual use or non-use of narcotic drugs, rather than a sampling at random in which the question of possible false positives or negatives cannot be conclusively answered. Although RIA is more sensitive than TLC, its advantage is apparent only in those cases where urine specimens are difficult to obtain frequently regularly or where the use of morphine is suspected by the positive identification of quinine in urine that was morphine-negative by TLC. In a selected group of negative and positive specimens chosen without conscious bias, the two methods gave consistently similar results, indicating that the modified TLC method provided a few or no false positives or negatives if the negatives were from those cases that were not positive anytime up to 3-4 days before urine collection. We conclude that RIA can be of significant value as a supplement to a TLC screening program, without sacrificing the many advantages that TLC has to offer.

  7. ClubSub-P: Cluster-Based Subcellular Localization Prediction for Gram-Negative Bacteria and Archaea

    PubMed Central

    Paramasivam, Nagarajan; Linke, Dirk

    2011-01-01

    The subcellular localization (SCL) of proteins provides important clues to their function in a cell. In our efforts to predict useful vaccine targets against Gram-negative bacteria, we noticed that misannotated start codons frequently lead to wrongly assigned SCLs. This and other problems in SCL prediction, such as the relatively high false-positive and false-negative rates of some tools, can be avoided by applying multiple prediction tools to groups of homologous proteins. Here we present ClubSub-P, an online database that combines existing SCL prediction tools into a consensus pipeline from more than 600 proteomes of fully sequenced microorganisms. On top of the consensus prediction at the level of single sequences, the tool uses clusters of homologous proteins from Gram-negative bacteria and from Archaea to eliminate false-positive and false-negative predictions. ClubSub-P can assign the SCL of proteins from Gram-negative bacteria and Archaea with high precision. The database is searchable, and can easily be expanded using either new bacterial genomes or new prediction tools as they become available. This will further improve the performance of the SCL prediction, as well as the detection of misannotated start codons and other annotation errors. ClubSub-P is available online at http://toolkit.tuebingen.mpg.de/clubsubp/ PMID:22073040

  8. False positive or negative results of shear-wave elastography in differentiating benign from malignant breast masses: analysis of clinical and ultrasonographic characteristics.

    PubMed

    Kim, Mi Young; Choi, Nami; Yang, Jung-Hyun; Yoo, Young Bum; Park, Kyoung Sik

    2015-10-01

    Shear-wave elastography (SWE) has the potential to improve diagnostic performance of conventional ultrasound (US) in differentiating benign from malignant breast masses. To investigate false positive or negative results of SWE in differentiating benign from malignant breast masses and to analyze clinical and imaging characteristics of the masses with false SWE findings. From May to October 2013, 166 breast lesions of 164 consecutive women (mean age, 45.3 ± 10.1 years) who had been scheduled for biopsy were included. Conventional US and SWE were performed in all women before biopsy. Clinical, ultrasonographic morphologic features and SWE parameters (pattern classification and standard deviation [SD]) were recorded and compared with the histopathology results. Patient and lesion factors in the "true" and "false" groups were compared. Of the 166 masses, 118 (71.1%) were benign and 48 (28.9%) were malignant. False SWE features were more frequently observed in benign masses. False positive rates of benign masses and false negative rates of malignancy were 53% and 8.2%, respectively, using SWE pattern analysis and were 22.4% and 10.3%, respectively, using SD values. A lesion boundary of the masses on US (P = 0.039) and younger patient age (P = 0.047) were significantly associated with false SWE findings. These clinical and ultrasonographic features need to be carefully evaluated in performance and interpretation of SWE examinations. © The Foundation Acta Radiologica 2014.

  9. Emotions and false memories: valence or arousal?

    PubMed

    Corson, Yves; Verrier, Nadège

    2007-03-01

    The effects of mood on false memories have not been studied systematically until recently. Some results seem to indicate that negative mood may reduce false recall and thus suggest an influence of emotional valence on false memory. The present research tested the effects of both valence and arousal on recall and recognition and indicates that the effect is actually due to arousal. In fact, whether participants' mood is positive, negative, or neutral, false memories are significantly more frequent under conditions of high arousal than under conditions of low arousal.

  10. Applying a CAD-generated imaging marker to assess short-term breast cancer risk

    NASA Astrophysics Data System (ADS)

    Mirniaharikandehei, Seyedehnafiseh; Zarafshani, Ali; Heidari, Morteza; Wang, Yunzhi; Aghaei, Faranak; Zheng, Bin

    2018-02-01

    Although whether using computer-aided detection (CAD) helps improve radiologists' performance in reading and interpreting mammograms is controversy due to higher false-positive detection rates, objective of this study is to investigate and test a new hypothesis that CAD-generated false-positives, in particular, the bilateral summation of false-positives, is a potential imaging marker associated with short-term breast cancer risk. An image dataset involving negative screening mammograms acquired from 1,044 women was retrospectively assembled. Each case involves 4 images of craniocaudal (CC) and mediolateral oblique (MLO) view of the left and right breasts. In the next subsequent mammography screening, 402 cases were positive for cancer detected and 642 remained negative. A CAD scheme was applied to process all "prior" negative mammograms. Some features from CAD scheme were extracted, which include detection seeds, the total number of false-positive regions, an average of detection scores and the sum of detection scores in CC and MLO view images. Then the features computed from two bilateral images of left and right breasts from either CC or MLO view were combined. In order to predict the likelihood of each testing case being positive in the next subsequent screening, two logistic regression models were trained and tested using a leave-one-case-out based cross-validation method. Data analysis demonstrated the maximum prediction accuracy with an area under a ROC curve of AUC=0.65+/-0.017 and the maximum adjusted odds ratio of 4.49 with a 95% confidence interval of [2.95, 6.83]. The results also illustrated an increasing trend in the adjusted odds ratio and risk prediction scores (p<0.01). Thus, the study showed that CAD-generated false-positives might provide a new quantitative imaging marker to help assess short-term breast cancer risk.

  11. Noninvasive Electromagnetic Detection of Bladder Cancer

    PubMed Central

    Cormio, Luigi; Vedruccio, Clarbruno; Leucci, Giorgio; Massenio, Paolo; Di Fino, Giuseppe; Cavaliere, Vincenzo; Carrieri, Giuseppe

    2014-01-01

    Objectives. Normal and neoplastic human tissues have different electromagnetic properties. This study aimed to determine the diagnostic accuracy of noninvasive electromagnetic detection of bladder cancer (BC) by the tissue-resonance interaction method (TRIM-prob). Patients and Methods. Consecutive patients were referred for cystoscopy because of (i) microscopic or gross hematuria and/or irritative voiding symptoms and (ii) bladder ultrasounds and urinary cytology findings negative or just suspicious of malignancy. Patients were first submitted to TRIM-prob bladder scanning by a single investigator and then to cystoscopy by another investigator blind to TRIM-prob data. Results. In 125 evaluated patients cystoscopy was positive for BC in 47 and negative in the remaining 78; conversely, TRIM-prob bladder scanning was positive for BC in 53 and negative in 72. In particular, TRIM-prob scanning yielded 7 false positives and only one false negative; therefore, its overall sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 97.9%, 89.9%, 86.8%, 98.6%, and 93.6%, respectively. Conclusions. TRIM-prob bladder scanning was a simple and quite accurate method for non-invasive electromagnetic detection of BC. If the elevated positive and negative predictive values will be replicated in further well-designed studies, it could be used to screen asymptomatic patients at high risk of BC. PMID:24563795

  12. Amplitude/frequency differences in a supine resting single-lead electrocardiogram of normal versus coronary heart diseased males.

    DOT National Transportation Integrated Search

    1974-05-01

    A resting 'normal' ECG can coexist with known angina pectoris, positive angiocardiography and previous myocardial infarction. In contemporary exercise ECG tests, a false positive/false negative total error of 10% is not unusual. Research aimed at imp...

  13. Are overreferrals on developmental screening tests really a problem?

    PubMed

    Glascoe, F P

    2001-01-01

    Developmental screening tests, even those meeting standards for screening test accuracy, produce numerous false-positive results for 15% to 30% of children. This is thought to produce unnecessary referrals for diagnostic testing or special services and increase the cost of screening programs. To explore whether children who pass screening tests differ in important ways from those who do not and to determine whether children overreferred for testing benefit from the scrutiny of diagnostic testing and treatment planning. Subjects were a national sample of 512 parents and their children (age range of the children, 7 months to 8 years) who participated in validation studies of various screening tests. Psychological examiners adhering to standardized directions obtained informed consent and administered at least 2 developmental screening measures (the Brigance Screens, the Battelle Developmental Inventory Screening Test, the Denver-II, and the Parents' Evaluations of Developmental Status) and a concurrent battery of diagnostic measures, including tests of intelligence, language, and academic achievement (for children aged 2(1/2) years and older). The performance on diagnostic measures of children who failed screening but were not found to have a disability (false positives) was compared with that of children who passed screening and did not have a disability on diagnostic testing (true negatives). Children with false-positive scores performed significantly (P<.001) lower on diagnostic measures than did children with true-negative scores. The false-positive group had scores in adaptive behavior, language, intelligence, and academic achievement that were 9 to 14 points lower than the scores of those in the true-negative group. When viewing the likelihood of scoring below the 25th percentile on diagnostic measures, children with false-positive scores had a relative risk of 2.6 in adaptive behavior (95% confidence interval [CI], 1.67-4.21), 3.1 in language skills (95% CI, 1.90-5.20), 6.7 on intelligence tests (95% CI, 3.28-13.50), and 4.9 on academic measures (95% CI, 2.61-9.28). Overall, 151 (70%) of the children with false-positive results scored below the 25th percentile on 1 or more diagnostic measures (the point at which most children have difficulty benefiting from typical classroom instruction) in contrast with 64 (29%) of the children with true-negative scores (odds ratio, 5.6; 95% CI, 3.73-8.49). Children with false-positive scores were also more likely to be nonwhite and to have parents who had not graduated from high school. Performance differences between children with true-negative scores and children with false-positive scores continued to be significant (P<.001) even after adjusting for sociodemographic differences between groups. Children overreferred for diagnostic testing by developmental screens perform substantially lower than children with true-negative scores on measures of intelligence, language, and academic achievement-the 3 best predictors of school success. These children also carry more psychosocial risk factors, such as limited parental education and minority status. Thus, children with false-positive screening results are an at-risk group for whom diagnostic testing may not be an unnecessary expense but rather a beneficial and needed service that can help focus intervention efforts. Although such testing will not indicate a need for special education placement, it can be useful in identifying children's needs for other programs known to improve language, cognitive, and academic skills, such as Head Start, Title I services, tutoring, private speech-language therapy, and quality day care.

  14. Shear wave elastography in the diagnosis of breast non-mass lesions: factors associated with false negative and false positive results.

    PubMed

    Park, So Yoon; Choi, Ji Soo; Han, Boo-Kyung; Ko, Eun Young; Ko, Eun Sook

    2017-09-01

    To investigate factors related to false shear wave elastography (SWE) results for breast non-mass lesions (NMLs) detected by B-mode US. This retrospective study enrolled 152 NMLs detected by B-mode US and later pathologically confirmed (79 malignant, 73 benign). All lesions underwent B-mode US and SWE. Quantitative (mean elasticity [E mean ]) and qualitative (maximum stiffness colour) SWE parameters were assessed, and 'E mean  > 85.1 kPa' or 'stiff colour (green to red)' determined malignancy. Final SWE results were matched to pathology results. Multivariate logistic regression analysis identified factors associated with false SWE results for diagnosis of breast NMLs. Associated calcifications (E mean : odds ratio [OR] = 7.60, P < 0.01; maximum stiffness colour: OR = 6.30, P = 0.02), in situ cancer compared to invasive cancer (maximum stiffness colour: OR = 5.29, P = 0.02), and lesion size (E mean : OR = 0.90, P < 0.01; maximum stiffness colour: OR = 0.91, P = 0.01) were significantly associated with false negative SWE results for malignant NMLs. Distance from the nipple (E mean : OR = 0.84, P = 0.03; maximum stiffness colour: OR = 0.93, P = 0.04) was significantly associated with false positive SWE results for benign NMLs. Presence of associated calcifications, absence of the invasive component, and smaller lesion size for malignant NMLs and shorter distance from the nipple for benign NMLs are factors significantly associated with false SWE results. • Calcification and size are associated with false negative SWE in malignant NMLs. • In situ cancer is associated with false negative SWE in malignant NMLs. • Distance from the nipple is associated with false positive SWE in benign NMLs. • These factors need consideration when performing SWE on breast NMLs.

  15. Influence of accurate and inaccurate 'split-time' feedback upon 10-mile time trial cycling performance.

    PubMed

    Wilson, Mathew G; Lane, Andy M; Beedie, Chris J; Farooq, Abdulaziz

    2012-01-01

    The objective of the study is to examine the impact of accurate and inaccurate 'split-time' feedback upon a 10-mile time trial (TT) performance and to quantify power output into a practically meaningful unit of variation. Seven well-trained cyclists completed four randomised bouts of a 10-mile TT on a SRM™ cycle ergometer. TTs were performed with (1) accurate performance feedback, (2) without performance feedback, (3) and (4) false negative and false positive 'split-time' feedback showing performance 5% slower or 5% faster than actual performance. There were no significant differences in completion time, average power output, heart rate or blood lactate between the four feedback conditions. There were significantly lower (p < 0.001) average [Formula: see text] (ml min(-1)) and [Formula: see text] (l min(-1)) scores in the false positive (3,485 ± 596; 119 ± 33) and accurate (3,471 ± 513; 117 ± 22) feedback conditions compared to the false negative (3,753 ± 410; 127 ± 27) and blind (3,772 ± 378; 124 ± 21) feedback conditions. Cyclists spent a greater amount of time in a '20 watt zone' 10 W either side of average power in the negative feedback condition (fastest) than the accurate feedback (slowest) condition (39.3 vs. 32.2%, p < 0.05). There were no significant differences in the 10-mile TT performance time between accurate and inaccurate feedback conditions, despite significantly lower average [Formula: see text] and [Formula: see text] scores in the false positive and accurate feedback conditions. Additionally, cycling with a small variation in power output (10 W either side of average power) produced the fastest TT. Further psycho-physiological research should examine the mechanism(s) why lower [Formula: see text] and [Formula: see text] scores are observed when cycling in a false positive or accurate feedback condition compared to a false negative or blind feedback condition.

  16. 18F-FDG SPECT/CT in the diagnosis of differentiated thyroid carcinoma with elevated thyroglobulin and negative iodine-131 scans.

    PubMed

    Ma, C; Wang, X; Shao, M; Zhao, L; Jiawei, X; Wu, Z; Wang, H

    2015-06-01

    Aim of the present study was to investigate the usefulness of 18F-FDG SPECT/CT in differentiated thyroid cancer (DTC) with elevated serum thyroglobulin (Tg) but negative iodine-131 scan. This retrospective review of patients with DTC recurrence who had 18F-FDG SPECT/CT and 18F-FDG PET/CT for elevated serum Tg but negative iodine-131 scan (March 2007-October 2012). After total thyroidectomy followed by radioiodine ablation, 86 consecutive patients with elevated Tg levels underwent 18F-FDG SPECT/CT or 18F-FDG PET/CT. Of these, 45 patients had 18F-FDG SPECT/CT, the other 41 patients had 18F-FDG PET/CT 3-4weeks after thyroid hormone withdrawal. The results of 18F-FDG PET/CT and SPECT/CT were correlated with patient follow-up information, which included the results from subsequent imaging modalities such as neck ultrasound, MRI and CT, Tg levels, and histologic examination of surgical specimens. The diagnostic accuracy of the two imaging modalities was evaluated. In 18F-FDG SPECT/CT scans, 24 (24/45) patients had positive findings, 22 true positive in 24 patients, false positive in 2 patients, true-negative and false-negative in 6, 15 patients, respectively. The overall sensitivity, specificity, and accuracy of 18F-FDG SPECT/CT were 59.5%, 75% and 62.2%, respectively. Twenty six patients had positive findings on 18F-FDG PET/CT scans, 23 true positive in 26 (26/41) patients, false positive in 3 patients, true-negative and false-negative in 9, 6 patients, respectively. The overall sensitivity, specificity, and accuracy of 18F-FDG PET/CT were 79.3%, 81.8% and 78.1%, respectively. Clinical management changed for 13 (29%) of 45 patients by 18F-FDG SPECT/CT, 14 (34%) of 41 patients by 18F-FDG PET/CT including surgery, radiation therapy, or multikinase inhibitor. Based on the retrospective analysis of 86 patients, 18F-FDG SPECT/CT has lower sensitivity in the diagnosis of DTC recurrence with elevated Tg and negative iodine-131scan to 18F-FDG PET/CT. The clinical application of FDG SPECT/CT is then limited and cannot replace PET/CT.

  17. Relevance of cutoff on a 4th generation ELISA performance in the false positive rate during HIV diagnostic in a low HIV prevalence setting.

    PubMed

    Chacón, Lucía; Mateos, María Luisa; Holguín, África

    2017-07-01

    Despite the high specificity of fourth-generation enzyme immunoassays (4th-gen-EIA) for screening during HIV diagnosis, their positive predictive value is low in populations with low HIV prevalence. Thus, screening should be optimized to reduce false positive results. The influence of sample cutoff (S/CO) values by a 4th-gen-EIA with the false positive rate during the routine HIV diagnosis in a low HIV prevalence population was evaluated. A total of 30,201 sera were tested for HIV diagnosis using Abbott Architect ® HIV-Ag/Ab-Combo 4th-gen-EIA at a hospital in Spain during 17 months. Architect S/CO values were recorded, comparing the HIV-1 positive results following Architect interpretation (S/CO≥1) with the final HIV-1 diagnosis by confirmatory tests (line immunoassay, LIA and/or nucleic acid test, NAT). ROC curve was also performed. Among the 30,201 HIV performed tests, 256 (0.85%) were positive according to Architect interpretation (S/CO≥1) but only 229 (0.76%) were definitively HIV-1 positive after LIA and/or NAT. Thus, 27 (10.5%) of 256 samples with S/CO≥1 by Architect were false positive diagnose. The false positive rate decreased when the S/CO ratio increased. All 19 samples with S/CO ≤10 were false positives and all 220 with S/CO>50 true HIV-positives. The optimal S/CO cutoff value provided by ROC curves was 32.7. No false negative results were found. We show that very low S/CO values during HIV-1 screening using Architect can result HIV negative after confirmation by LIA and NAT. The false positive rate is reduced when S/CO increases. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. How Reliable Is the Alpha-defensin Immunoassay Test for Diagnosing Periprosthetic Joint Infection? A Prospective Study.

    PubMed

    Bonanzinga, Tommaso; Zahar, Akos; Dütsch, Michael; Lausmann, Christian; Kendoff, Daniel; Gehrke, Thorsten

    2017-02-01

    A key issue in the treatment of periprosthetic joint infection (PJI) is the correct diagnosis. The main problem is lack of diagnostic tools able to diagnose a PJI with high accuracy. Alpha-defensin has been proposed as a possible solution, but in the current literature, there is a lack of independent validation. We performed a prospective study to determine (1) what is the sensitivity, specificity, and positive and the negative predictive values of the alpha-defensin immunoassay test in diagnosing PJI; and (2) which clinical features may be responsible for false-positive and false-negative results? Preoperative aspiration was performed in all patients presenting with a painful hip/knee arthroplasty, including both primary and revision implants. Metallosis, other inflammatory comorbidities, and previous/concomitant antibiotic therapy were not considered as exclusion criteria. An inadequate amount of synovial fluid for culture was an exclusion criterion. A total of 156 patients (65 knees, 91 hips) were included in this prospective study. At the time of revision, synovial fluid samples were taken to perform the alpha-defensin assay. During surgical débridement of tissue, samples for cultures and histologic evaluation were taken, and samples were cultured until positive or until negative at 14 days. A diagnosis of PJI was confirmed in 29 patients according to the International Consensus Group on PJI. The sensitivity of the alpha-defensin immunoassay was 97% (95% confidence interval [CI], 92%-99%), the specificity was 97% (95% CI, 92%-99%), the positive predictive value was 88% (95% CI, 81%-92%), and the negative predictive value was 99% (95% CI, 96%-99%). Among four false-positive patients, two had metallosis and one had polyethylene wear. The false-negative case presented with a draining sinus, and intraoperative cultures were also negative. Alpha-defensin assay appears to be a reliable test, but followup evaluation is needed to estimate longer term performance of the test. The authors believe that alpha-defensin has demonstrated itself to be sufficiently robust that PJI diagnostic criteria now should include this test. Future studies are needed to compare the differences among the diagnostic capability of the available tests, in particular when metallosis is present, because metallosis may predispose the test to a false-positive result. Level I, diagnostic study.

  19. False negative fecal occult blood test may be associated with increased mortality from colorectal cancer.

    PubMed

    Half, Elizabeth E; Mlynarsky, Liat; Naftali, Timna; Benjaminov, Fabiana; Konikoff, Fred M

    2013-09-01

    Fecal Occult Blood Test (FOBT) is an accepted screening test for colorectal cancer (CRC). It has been shown to decrease mortality by up to 30%. The outcome of screening failures has not been adequately studied. The purpose of this study was to assess the outcome of patients who were diagnosed with CRC after a false negative FOBT. We identified all consecutive CRCs from pathology reports between 2005 and 2010. Patients were divided according to their FOBT result. Those who became positive were compared to patients who remained negative. Altogether 401 CRCs were identified. Of those, 202 never performed a FOBT. At least one negative FOBT was performed by 133 individuals (67%). Of these, 76 remained negative (false negatives, FN) and 57 became positive (positive conversion, PC, controls). The prevalence of metastatic disease was threefold higher among the FNs as compared to the PC group (16 [22.2%] vs. 4 [7.5%], P=0.022). All-cause mortality was also significantly higher among FNs versus PCs (24 [31.6%] vs. 5 [8.8%], P=0.001); in Cox regression analysis of survival (covariates: FNs vs. PC, gender, age, medications and co-morbidities) FNs had increased mortality compared to the PC (HR 2.929, P=0.033, CI 95% 1.092-7.858). No statistically significant difference was found regarding all primary end points when comparing the FN and the "No test" group. These data disclose a particular risk of FOBT as a screening test. A subgroup of patients with "false" negative tests may have increased morbidity and mortality. Efforts should be made to recognize and characterize this high-risk group.

  20. Masking as an effective quality control method for next-generation sequencing data analysis.

    PubMed

    Yun, Sajung; Yun, Sijung

    2014-12-13

    Next generation sequencing produces base calls with low quality scores that can affect the accuracy of identifying simple nucleotide variation calls, including single nucleotide polymorphisms and small insertions and deletions. Here we compare the effectiveness of two data preprocessing methods, masking and trimming, and the accuracy of simple nucleotide variation calls on whole-genome sequence data from Caenorhabditis elegans. Masking substitutes low quality base calls with 'N's (undetermined bases), whereas trimming removes low quality bases that results in a shorter read lengths. We demonstrate that masking is more effective than trimming in reducing the false-positive rate in single nucleotide polymorphism (SNP) calling. However, both of the preprocessing methods did not affect the false-negative rate in SNP calling with statistical significance compared to the data analysis without preprocessing. False-positive rate and false-negative rate for small insertions and deletions did not show differences between masking and trimming. We recommend masking over trimming as a more effective preprocessing method for next generation sequencing data analysis since masking reduces the false-positive rate in SNP calling without sacrificing the false-negative rate although trimming is more commonly used currently in the field. The perl script for masking is available at http://code.google.com/p/subn/. The sequencing data used in the study were deposited in the Sequence Read Archive (SRX450968 and SRX451773).

  1. To err is human, to correct is public health: a systematic review examining poor quality testing and misdiagnosis of HIV status.

    PubMed

    Johnson, Cheryl C; Fonner, Virginia; Sands, Anita; Ford, Nathan; Obermeyer, Carla Mahklouf; Tsui, Sharon; Wong, Vincent; Baggaley, Rachel

    2017-08-29

    In accordance with global testing and treatment targets, many countries are seeking ways to reach the "90-90-90" goals, starting with diagnosing 90% of all people with HIV. Quality HIV testing services are needed to enable people with HIV to be diagnosed and linked to treatment as early as possible. It is essential that opportunities to reach people with undiagnosed HIV are not missed, diagnoses are correct and HIV-negative individuals are not inadvertently initiated on life-long treatment. We conducted this systematic review to assess the magnitude of misdiagnosis and to describe poor HIV testing practices using rapid diagnostic tests. We systematically searched peer-reviewed articles, abstracts and grey literature published from 1 January 1990 to 19 April 2017. Studies were included if they used at least two rapid diagnostic tests and reported on HIV misdiagnosis, factors related to potential misdiagnosis or described quality issues and errors related to HIV testing. Sixty-four studies were included in this review. A small proportion of false positive (median 3.1%, interquartile range (IQR): 0.4-5.2%) and false negative (median: 0.4%, IQR: 0-3.9%) diagnoses were identified. Suboptimal testing strategies were the most common factor in studies reporting misdiagnoses, particularly false positive diagnoses due to using a "tiebreaker" test to resolve discrepant test results. A substantial proportion of false negative diagnoses were related to retesting among people on antiretroviral therapy. Conclusions HIV testing errors and poor practices, particularly those resulting in false positive or false negative diagnoses, do occur but are preventable. Efforts to accelerate HIV diagnosis and linkage to treatment should be complemented by efforts to improve the quality of HIV testing services and strengthen the quality management systems, particularly the use of validated testing algorithms and strategies, retesting people diagnosed with HIV before initiating treatment and providing clear messages to people with HIV on treatment on the risk of a "false negative" test result.

  2. Residual risk of bacterial contamination of platelets: six years of experience with sterility testing.

    PubMed

    Ramirez-Arcos, Sandra; DiFranco, Caesar; McIntyre, Terri; Goldman, Mindy

    2017-09-01

    Canadian Blood Services screens 100% of platelet concentrates (PCs) for bacterial contamination with the BacT/ALERT system. Quality-control sterility testing of 1% (≥10 units) of outdated PCs is performed monthly. Data from routine screening, quality-control testing, and septic reactions obtained from 2010 to 2016 are presented herein. In total, 601,988 buffy coat PC pools and 186,737 apheresis PCs were routinely screened with aerobic cultures over 6 years. Outdate quality-control testing of 8535 buffy coat and 8498 apheresis PCs was performed using aerobic and anaerobic cultures during the same period. Results were classified as "true-positives" when the same bacterium was isolated in initial and confirmatory cultures or "false-negatives" when bacteria were missed in early screening and were captured during quality-control sterility testing or through investigation of sepsis cases. During routine screening, the true-positive rates between buffy coat (0.94 per 10,000) and apheresis (0.96 per 10,000) PCs were similar (p = 0.9473). Seventy-five bacteria isolated during PC screening included Gram-positive and Gram-negative organisms. Six false-negative septic reactions were reported that implicated coagulase-negative staphylococci (n = 3) and Staphylococcus aureus (n = 3) for approximate rates of 1 per 100,000 transfusion reactions and 1 per 500,000 fatalities. During quality-control testing, the false-negative rates between buffy coat (8 per 10,000) and apheresis (9 per 10,000) PCs were similar (p = 0.7897). All 15 quality-control isolates were Gram-positive bacteria. The current bacterial screening protocol is efficacious for identifying Gram-negative bacteria. However, the high proportion of Gram-positive organisms detected on outdate quality-control testing and septic transfusion events demonstrates a residual safety risk that merits further intervention. © 2017 AABB.

  3. Assessment of rates of recanting and hair testing as a biological measure of drug use in a general population sample of young people.

    PubMed

    Taylor, Michelle; Sullivan, John; Ring, Susan M; Macleod, John; Hickman, Matthew

    2017-03-01

    We investigate the extent of and factors associated with denial of previously reported cannabis and other illicit drug use, and assess the potential of hair testing for measuring substance use in general population samples. Birth cohort study. United Kingdom, 1991-present. A total of 3643 participants who provided hair and self-report measures of cannabis and other illicit drug use in the Avon Longitudinal Study of Parents and Children (ALSPAC) at age 18 years. Denial of ever use of cannabis and other illicit drugs at age 18 following previously reported use. Positive hair drug tests for cannabis and other illicit drugs, and expected numbers of false positives and false negatives based on expected sensitivity and specificity. Cannabis and other illicit drug use was reported by 1223 and 393 individuals, respectively, before age 18 years. Of these 176 (14.4%) and 99 (25.2%), respectively, denied use at age 18. Denial of cannabis use decreased with the reporting of other substances and antisocial behaviour. Cannabis and other illicit drug use at age 18 was reported by 547 (22.5%) and 203 (8.4%) individuals, respectively. Of these, 111 (20.3%) and 13 (6.4%) were hair-positive for cannabis and other illicit drugs, respectively. Based on hair testing for cannabis use we expect 0 [95% confidence interval (CI) = 0-169] false positives and 394 (95% CI = 323-449) false negatives compared to observed 362 potential false positives and 436 potential false negatives based on self-report. In hair-positive individuals, reporting the use of other substances and antisocial behaviour decreased the odds of a negative self-report. Hair analysis provides an unreliable marker of substance use in general population samples. People who report more frequent substance use before age 18 are less likely to later deny previous substance use at age 18 than people who report occasional use. © 2016 The Authors. Addiction published by John Wiley & Sons Ltd on behalf of Society for the Study of Addiction.

  4. Assessment of rates of recanting and hair testing as a biological measure of drug use in a general population sample of young people

    PubMed Central

    Sullivan, John; Ring, Susan M.; Macleod, John; Hickman, Matthew

    2016-01-01

    Abstract Aims We investigate the extent of and factors associated with denial of previously reported cannabis and other illicit drug use, and assess the potential of hair testing for measuring substance use in general population samples. Design Birth cohort study. Setting United Kingdom, 1991–present. Participants A total of 3643 participants who provided hair and self‐report measures of cannabis and other illicit drug use in the Avon Longitudinal Study of Parents and Children (ALSPAC) at age 18 years. Measurements Denial of ever use of cannabis and other illicit drugs at age 18 following previously reported use. Positive hair drug tests for cannabis and other illicit drugs, and expected numbers of false positives and false negatives based on expected sensitivity and specificity. Findings Cannabis and other illicit drug use was reported by 1223 and 393 individuals, respectively, before age 18 years. Of these 176 (14.4%) and 99 (25.2%), respectively, denied use at age 18. Denial of cannabis use decreased with the reporting of other substances and antisocial behaviour. Cannabis and other illicit drug use at age 18 was reported by 547 (22.5%) and 203 (8.4%) individuals, respectively. Of these, 111 (20.3%) and 13 (6.4%) were hair‐positive for cannabis and other illicit drugs, respectively. Based on hair testing for cannabis use we expect 0 [95% confidence interval (CI) = 0–169] false positives and 394 (95% CI = 323–449) false negatives compared to observed 362 potential false positives and 436 potential false negatives based on self‐report. In hair‐positive individuals, reporting the use of other substances and antisocial behaviour decreased the odds of a negative self‐report. Conclusions Hair analysis provides an unreliable marker of substance use in general population samples. People who report more frequent substance use before age 18 are less likely to later deny previous substance use at age 18 than people who report occasional use. PMID:27743424

  5. Quality control in the diagnosis of Trichuris trichiura and Ascaris lumbricoides using the Kato-Katz technique: experience from three randomised controlled trials.

    PubMed

    Speich, Benjamin; Ali, Said M; Ame, Shaali M; Albonico, Marco; Utzinger, Jürg; Keiser, Jennifer

    2015-02-05

    An accurate diagnosis of soil-transmitted helminthiasis is important for individual patient management, for drug efficacy evaluation and for monitoring control programmes. The Kato-Katz technique is the most widely used method detecting soil-transmitted helminth eggs in faecal samples. However, detailed analyses of quality control, including false-positive and faecal egg count (FEC) estimates, have received little attention. Over a 3-year period, within the frame of a series of randomised controlled trials conducted in Pemba, United Republic of Tanzania, 10% of randomly selected Kato-Katz thick smears were re-read for Trichuris trichiura and Ascaris lumbricoides eggs. In case of discordant result (i.e. positive versus negative) the slides were re-examined a third time. A result was assumed to be false-positive or false-negative if the result from the initial reading did not agree with the quality control as well as the third reading. We also evaluated the general agreement in FECs between the first and second reading, according to internal and World Health Organization (WHO) guidelines. From the 1,445 Kato-Katz thick smears subjected to quality control, 1,181 (81.7%) were positive for T. trichiura and 290 (20.1%) were positive for A. lumbricoides. During quality control, very low rates of false-positive results were observed; 0.35% (n = 5) for T. trichiura and 0.28% (n = 4) for A. lumbricoides. False-negative readings of Kato-Katz thick smears were obtained in 28 (1.94%) and 6 (0.42%) instances for T. trichiura and A. lumbricoides, respectively. A high frequency of discordant results in FECs was observed (i.e. 10.0-23.9% for T. trichiura, and 9.0-11.4% for A. lumbricoides). Our analyses show that the rate of false-positive diagnoses of soil-transmitted helminths is low. As the probability of false-positive results increases after examination of multiple stool samples from a single individual, the potential influence of false-positive results on epidemiological studies and anthelminthic drug efficacy studies should be determined. Existing WHO guidelines for quality control might be overambitious and might have to be revised, specifically with regard to handling disagreements in FECs.

  6. Predictors of false negative sentinel lymph node biopsy in trunk and extremity melanoma.

    PubMed

    Sinnamon, Andrew J; Neuwirth, Madalyn G; Bartlett, Edmund K; Zaheer, Salman; Etherington, Mark S; Xu, Xiaowei; Elder, David E; Czerniecki, Brian J; Fraker, Douglas L; Karakousis, Giorgos C

    2017-12-01

    Nodal recurrence following negative sentinel lymph node biopsy (SLNB) for melanoma is known as false-negative (FN) SLNB. Risk factors for FN SLNB among patients with trunk and extremity melanoma have not been well-defined. After retrospective review, SLNB procedures were classified FN, true positive (TP; positive SLNB), or true negative (TN; negative SLNB without recurrence). Factors associated with high false negative rate (FNR) and low negative predictive value (NPV) were identified by comparing FNs to TPs and TNs, respectively. Survival was evaluated using Kaplan-Meier methods. Of 1728 patients, 234 were TP and 37 were FN for overall FNR of 14% and NPV of 97.5%. Age ≥65 years was independently associated with high FNR (FNR 20% in this group). Breslow thickness >1 mm and ulceration were independently associated with low NPV. Among patients with ulcerated tumors >4 mm, NPV was 88%. Median time to recurrence for FNs was 13 months. Among patients with primary melanomas ≤2 mm in depth, overall and distant disease-free survival were significantly shorter with FN SLNB than TP SLNB. Older age is associated with increased FNR; patients with thick, ulcerated lesions should be considered for increased nodal surveillance after negative SLNB given low NPV in this group. © 2017 Wiley Periodicals, Inc.

  7. Antituberculosis IgG Antibodies as a Marker of Active Mycobacterium tuberculosis Disease

    PubMed Central

    Welch, Ryan J.; Lawless, Kathleen M.

    2012-01-01

    Anti-Mycobacterium tuberculosis IgG antibodies may aid in the diagnosis of active M. tuberculosis disease. We studied whether anti-M. tuberculosis IgG antibodies are elevated in active M. tuberculosis disease and assessed factors contributing to false-positive and -negative results. A retrospective study of 2,150 individuals tested by the QuantiFERON-TB Gold In-Tube (QFT-GIT) assay was conducted at the University of Utah, ARUP Laboratories, November 2008 to December 2010. All samples were tested with the InBios Active TbDetect antituberculosis (anti-TB) IgG antibody assay. Of 1,044 patients with a positive QFT-GIT, 59 (5.7%) were positive for M. tuberculosis antibodies. Fourteen of 1,106 (1.3%) with a negative or indeterminate QFT-GIT were positive for M. tuberculosis antibodies. M. tuberculosis antibody tests were positive in 61.5% with confirmed active M. tuberculosis disease and other mycobacterial infections. Over half of the false-negative M. tuberculosis antibody tests occurred in patients ≥90 years of age. False positives were seen in 12.9% of autoimmune patients. The odds ratio of being positive by the QFT-GIT and the InBios TB IgG assay increased with confirmed M. tuberculosis disease or highly suspected M. tuberculosis disease and was 86.7 (95% confidence interval [CI], 34.4 to 218.5) in these two groups compared to patients negative by both tests. Although anti-M. tuberculosis antibodies can be detected in patients with active M. tuberculosis disease, caution should be used with patients where immunoglobulin levels may be decreased or patients with autoantibodies. PMID:22301692

  8. Neuroblastoma Screening

    MedlinePlus

    ... including physical and emotional problems. False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...

  9. Six years' experience of using the BacT/ALERT system to screen all platelet concentrates, and additional testing of outdated platelet concentrates to estimate the frequency of false-negative results.

    PubMed

    Larsen, C P; Ezligini, F; Hermansen, N O; Kjeldsen-Kragh, J

    2005-02-01

    Approximately 1 in every 2000 units of platelets is contaminated with bacteria. The BacT/ALERT automated blood culture system can be used to screen platelet concentrates (PCs) for bacterial contamination. Data were collected from May 1998 until May 2004. The number of PCs tested during this period was 36 896, most of which were produced from pools of four buffy-coats. On the day following blood collection or platelet apheresis, a 5-10 ml sample of the PC was aseptically transferred to a BacT/ALERT culture bottle for detection of aerobic bacteria. The sample was monitored for bacterial growth during the entire storage period of the PC (6.5 days). When a positive signal was generated, the culture bottle, the PC and the erythrocyte concentrates were tested for bacterial growth. In order to determine the frequency of false-negative BacT/ALERT signals, 1061 outdated PCs were tested during the period from May 2002 to May 2004. Eighty-eight positive signals were detected by the BacT/ALERT system, of which 12 were interpreted as truly positive. Fourteen signals were interpreted as truly false positive. Thirty-three signals were interpreted to be probably false positive. Two of 1061 outdated units tested positive, and Bacillus spp. and Staphylococcus epidermidis, respectively, were isolated from these PCs. Between 0.03% and 0.12% of the PCs were contaminated with bacteria. BacT/ALERT is an efficient tool for monitoring PCs for bacterial contamination; however, it is important to realize that false-negative results may occur.

  10. Skin Cancer Screening

    MedlinePlus

    ... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...

  11. FTA-ABS test

    MedlinePlus

    ... rule out a possible false-negative result. Normal Results A negative or nonreactive result means that you ... meaning of your specific test results. What Abnormal Results Mean A positive FTA-ABS is often a ...

  12. Easy fix for clinical laboratories for the false-positive defect with the Abbott AxSym total beta-hCG test.

    PubMed

    Cole, Laurence A; Khanlian, Sarah A

    2004-05-01

    False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.

  13. Mnemonic transmission, social contagion, and emergence of collective memory: Influence of emotional valence, group structure, and information distribution.

    PubMed

    Choi, Hae-Yoon; Kensinger, Elizabeth A; Rajaram, Suparna

    2017-09-01

    Social transmission of memory and its consequence on collective memory have generated enduring interdisciplinary interest because of their widespread significance in interpersonal, sociocultural, and political arenas. We tested the influence of 3 key factors-emotional salience of information, group structure, and information distribution-on mnemonic transmission, social contagion, and collective memory. Participants individually studied emotionally salient (negative or positive) and nonemotional (neutral) picture-word pairs that were completely shared, partially shared, or unshared within participant triads, and then completed 3 consecutive recalls in 1 of 3 conditions: individual-individual-individual (control), collaborative-collaborative (identical group; insular structure)-individual, and collaborative-collaborative (reconfigured group; diverse structure)-individual. Collaboration enhanced negative memories especially in insular group structure and especially for shared information, and promoted collective forgetting of positive memories. Diverse group structure reduced this negativity effect. Unequally distributed information led to social contagion that creates false memories; diverse structure propagated a greater variety of false memories whereas insular structure promoted confidence in false recognition and false collective memory. A simultaneous assessment of network structure, information distribution, and emotional valence breaks new ground to specify how network structure shapes the spread of negative memories and false memories, and the emergence of collective memory. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  14. Diagnostic performance of influenza viruses and RSV rapid antigen detection tests in children in tertiary care.

    PubMed

    Moesker, F M; van Kampen, J J A; Aron, G; Schutten, M; van de Vijver, D A M C; Koopmans, M P G; Osterhaus, A D M E; Fraaij, P L A

    2016-06-01

    Rapid antigen detection tests (RADTs) are increasingly used to detect influenza viruses and respiratory syncytial virus (RSV). However, their sensitivity and specificity are a matter of debate, challenging their clinical usefulness. Comparing diagnostic performances of BinaxNow Influenza AB(®) (BNI) and BinaxNow RSV(®) (BNR), to those of real-time reverse transcriptase PCR (RT-PCR), virus isolation and direct immunofluorescence (D-IF) in paediatric patients. Between November 2005 and September 2013, 521 nasal washings from symptomatic children (age <5 years) attending our tertiary care centre were tested, with a combination of the respective assays using RT-PCR as gold standard. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of BNI were 69% (confidence interval [CI] [51-83]), 96% [94-97], 55% [39-70] and 98% [96-99] respectively. Of eleven false-negative samples, RT-PCR Ct-values were higher than all RT-PCR positive test results (27 vs 22, p=0.012). Of twenty false-positive samples, none were culture positive and two tested positive in D-IF. Sensitivity, specificity, PPV and NPV for BNR were 79% [73-85], 98% [96-99], 97% [93-99] and 88% [84-91]. Of the 42 false-negative samples the median Ct-value was higher than that of all RT-PCR positive samples (31 vs 23, p<0.0001). Five false-positive samples were detected. Three of these tested positive for RSV in virus isolation and D-IF. RADTs have a high specificity with BNR being superior to BNI. However, their relative low sensitivity limits their usefulness for clinical decision making in a tertiary care paediatric hospital. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  15. A novel one-class SVM based negative data sampling method for reconstructing proteome-wide HTLV-human protein interaction networks.

    PubMed

    Mei, Suyu; Zhu, Hao

    2015-01-26

    Protein-protein interaction (PPI) prediction is generally treated as a problem of binary classification wherein negative data sampling is still an open problem to be addressed. The commonly used random sampling is prone to yield less representative negative data with considerable false negatives. Meanwhile rational constraints are seldom exerted on model selection to reduce the risk of false positive predictions for most of the existing computational methods. In this work, we propose a novel negative data sampling method based on one-class SVM (support vector machine, SVM) to predict proteome-wide protein interactions between HTLV retrovirus and Homo sapiens, wherein one-class SVM is used to choose reliable and representative negative data, and two-class SVM is used to yield proteome-wide outcomes as predictive feedback for rational model selection. Computational results suggest that one-class SVM is more suited to be used as negative data sampling method than two-class PPI predictor, and the predictive feedback constrained model selection helps to yield a rational predictive model that reduces the risk of false positive predictions. Some predictions have been validated by the recent literature. Lastly, gene ontology based clustering of the predicted PPI networks is conducted to provide valuable cues for the pathogenesis of HTLV retrovirus.

  16. Risks of Skin Cancer Screening

    MedlinePlus

    ... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...

  17. Skin testing for immediate hypersensitivity to corticosteroids: a case series and literature review.

    PubMed

    Baker, A; Empson, M; The, R; Fitzharris, P

    2015-03-01

    Immediate hypersensitivity to corticosteroids is reported to occur with an incidence of 0.1%. The largest previous case series reporting corticosteroid skin testing has seven patients. We identified 23 patients (mean age 50 years, 65% female) from Auckland City Hospital who underwent skin testing (ST) for suspected corticosteroid hypersensitivity between July 2005 and April 2012. We performed a retrospective clinical case note review detailing clinical history of reaction, skin test results and subsequent management. Most patients (21/23) had a standard panel of testing with prednisolone, triamcinolone, methylprednisolone, hydrocortisone and dexamethasone. Skin tests used a 10% steroid stock concentration for skin prick tests (SPT) and dilutions of 1 : 1000, 1 : 100 and 1 : 10 for subsequent intradermal testing. A weal 3 mm greater than the negative control was considered positive. A total of 23 patients were identified who had skin testing for suspected acute hypersensitivity to corticosteroids, eight of which had a history of anaphylaxis. From 28 reactions (in 23 patients), the most common route of administration was intra-articular (13), followed by oral (7), intravenous (3) and other (5). Skin tests were positive in 8/23 patients, and 7/8 of these patients had a history of corticosteroid-associated anaphylaxis. Skin tests were positive at either the skin prick test or intradermal stages. There was evidence suggesting clinical and skin test cross-reactivity between corticosteroids in one patient. One patient had a positive skin test, but negative oral challenge suggesting the skin test was false positive. Skin tests were negative in 15/23 patients. One patient had a negative prednisolone skin test and positive unblinded oral challenge, suggesting a false-negative skin test. Skin testing can provide sufficient evidence to diagnose allergy in patients with a clear history of immediate hypersensitivity to corticosteroids such as anaphylaxis. Both skin prick and intradermal tests should be used. There is evidence of cross-reactivity between steroids, so a panel is recommended. False-positive and false-negative reactions do occur; however, the frequency is unknown. Challenge remains the only definitive way to demonstrate a safe alternative to use. As the largest case series described, this article provides new evidence for the interpretation of skin tests when investigating possible immediate hypersensitivity to corticosteroids. © 2014 John Wiley & Sons Ltd.

  18. Discrete emotion-congruent false memories in the DRM paradigm.

    PubMed

    Bland, Cassandra E; Howe, Mark L; Knott, Lauren

    2016-08-01

    Research has shown that false-memory production is enhanced for material that is emotionally congruent with the mood of the participant at the time of encoding. So far this research has only been conducted to examine the influence of generic negative affective mood states and generic negative stimuli on false-memory production. In addition, much of the research is limited as it focuses on valence and arousal dimensions, and fails to take into account the more comprehensive nature of emotions. The current study demonstrates that this effect goes beyond general negative or positive moods and acts at a more discrete emotional level. Participants underwent a standard emotion-induction procedure before listening to negative emotional or neutral associative word lists. The emotions induced, negative word lists, and associated nonpresented critical lures, were related to either fear or anger, 2 negative valence emotions that are also both high in arousal. Results showed that when valence and arousal are controlled for, false memories are more likely to be produced for discrete emotionally congruent compared with incongruent materials. These results support spreading activation theories of false remembering and add to our understanding of the adaptive nature of false-memory production. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  19. False-negative rate of gram-stain microscopy for diagnosis of septic arthritis: suggestions for improvement.

    PubMed

    Stirling, Paul; Faroug, Radwane; Amanat, Suheil; Ahmed, Abdulkhaled; Armstrong, Malcolm; Sharma, Pankaj; Qamruddin, Ahmed

    2014-01-01

    We quantify the false-negative diagnostic rate of septic arthritis using Gram-stain microscopy of synovial fluid and compare this to values reported in the peer-reviewed literature. We propose a method of improving the diagnostic value of Gram-stain microscopy using Lithium Heparin containers that prevent synovial fluid coagulation. Retrospective study of the Manchester Royal Infirmary microbiology database of patients undergoing synovial fluid Gram-stain and culture between December 2003 and March 2012 was undertaken. The initial cohort of 1896 synovial fluid analyses for suspected septic arthritis was reduced to 143 after exclusion criteria were applied. Analysis of our Gram-stain microscopy yielded 111 false-negative results from a cohort size of 143 positive synovial fluid cultures, giving a false-negative rate of 78%. We report a false-negative rate of Gram-stain microscopy for septic arthritis of 78%. Clinicians should therefore avoid the investigation until a statistically significant data set confirms its efficacy. The investigation's value could be improved by using Lithium Heparin containers to collect homogenous synovial fluid samples. Ongoing research aims to establish how much this could reduce the false-negative rate.

  20. [Examination about utility of a Streptococcus pneumoniae capsular antigen swiftness search kit urine in a pneumonia patient].

    PubMed

    Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi

    2005-01-01

    We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.

  1. Direct versus indirect molecular diagnosis of fragile X mental retardation in 40 German families at risk.

    PubMed

    Knobloch, O; Pelz, F; Wick, U; Nelson, D L; Zoll, B

    1993-03-01

    In order to test whether the direct molecular diagnostic approach for fragile X mental retardation (Martin-Bell syndrome, MBS) really makes diagnosis of this disease more precise, we evaluated the results of direct diagnosis in 40 German families at risk together with the results of an earlier study with closely linked flanking markers in the same families. Of 84 men analysed, 43 showed clinical signs. In 39 of these affected men the disease could be confirmed by direct diagnosis. Compared to cytogenetic data, one man was false negative and two were false positive. Two men, whose status could not be determined by means of RFLP data, proved to be normal transmitting males (NTMs). However, the possibility of being an NTM had to be rejected in one case on RFLP data. Fragile X syndrome could be confirmed in 10 of the 13 women with clinical signs. Compared to cytogenetic data there were three cases of false negative results and one of false positive. All 36 obligate carrier women were detected by the direct approach. In addition, 22 women were newly identified as normal transmitting females (NTFs), among them one woman who could not be identified by cytogenetic means or by analysis with closely linked markers. These findings are discussed in view of the relative reliability of the three diagnostic approaches to MBS. Special attention is drawn to the significance of false negative and false positive results in direct diagnosis.

  2. Accuracy and reliability of forensic latent fingerprint decisions

    PubMed Central

    Ulery, Bradford T.; Hicklin, R. Austin; Buscaglia, JoAnn; Roberts, Maria Antonia

    2011-01-01

    The interpretation of forensic fingerprint evidence relies on the expertise of latent print examiners. The National Research Council of the National Academies and the legal and forensic sciences communities have called for research to measure the accuracy and reliability of latent print examiners’ decisions, a challenging and complex problem in need of systematic analysis. Our research is focused on the development of empirical approaches to studying this problem. Here, we report on the first large-scale study of the accuracy and reliability of latent print examiners’ decisions, in which 169 latent print examiners each compared approximately 100 pairs of latent and exemplar fingerprints from a pool of 744 pairs. The fingerprints were selected to include a range of attributes and quality encountered in forensic casework, and to be comparable to searches of an automated fingerprint identification system containing more than 58 million subjects. This study evaluated examiners on key decision points in the fingerprint examination process; procedures used operationally include additional safeguards designed to minimize errors. Five examiners made false positive errors for an overall false positive rate of 0.1%. Eighty-five percent of examiners made at least one false negative error for an overall false negative rate of 7.5%. Independent examination of the same comparisons by different participants (analogous to blind verification) was found to detect all false positive errors and the majority of false negative errors in this study. Examiners frequently differed on whether fingerprints were suitable for reaching a conclusion. PMID:21518906

  3. Signal detection of adverse events with imperfect confirmation rates in vaccine safety studies using self-controlled case series design.

    PubMed

    Xu, Stanley; Newcomer, Sophia; Nelson, Jennifer; Qian, Lei; McClure, David; Pan, Yi; Zeng, Chan; Glanz, Jason

    2014-05-01

    The Vaccine Safety Datalink project captures electronic health record data including vaccinations and medically attended adverse events on 8.8 million enrollees annually from participating managed care organizations in the United States. While the automated vaccination data are generally of high quality, a presumptive adverse event based on diagnosis codes in automated health care data may not be true (misclassification). Consequently, analyses using automated health care data can generate false positive results, where an association between the vaccine and outcome is incorrectly identified, as well as false negative findings, where a true association or signal is missed. We developed novel conditional Poisson regression models and fixed effects models that accommodate misclassification of adverse event outcome for self-controlled case series design. We conducted simulation studies to evaluate their performance in signal detection in vaccine safety hypotheses generating (screening) studies. We also reanalyzed four previously identified signals in a recent vaccine safety study using the newly proposed models. Our simulation studies demonstrated that (i) outcome misclassification resulted in both false positive and false negative signals in screening studies; (ii) the newly proposed models reduced both the rates of false positive and false negative signals. In reanalyses of four previously identified signals using the novel statistical models, the incidence rate ratio estimates and statistical significances were similar to those using conventional models and including only medical record review confirmed cases. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. The risk factor of false-negative and false-positive for T-SPOT.TB in active tuberculosis.

    PubMed

    Di, Li; Li, Yan

    2018-02-01

    T-SPOT.TB is a promising diagnosis tool to identify both pulmonary tuberculosis and extrapulmonary tuberculosis, as well as latent tuberculosis; however, the factors that affect the results of T-SPOT.TB remains unclear. In this study, we aim to figure out the risk factor of T-SPOT.TB for active TB. A total of 349 patients were recruited between January 1st, 2016 and January 22st, 2017 at Renmin Hospital of Wuhan University, including 98 subjects with TB and 251 subjects with non-TB disease, and received T-SPOT.TB (Oxford Immunotec Ltd). Statistics were analyzed by SPSS 19.0 using logistic regression. The overall specificity and sensitivity of the T-SPOT.TB was 92.83% (233/251; 95%CI 0.8872-0.9557) and 83.67% (82/98; 95%CI 0.7454-0.9010), respectively. Patients with tuberculous meningitis were more likely to have false-negative results (OR 17.4, 95%CI 3.068-98.671; P<.001) while patients with cured TB tended to induce false-positive results (OR 30.297; 95%CI 7.069-129.849; P<.001). The results were not affected by sex, age, onset time, smoke, alcohol, treatment, allergic history, co-morbidity, TB (exclude tuberculous meningitis) (P>.05). Tuberculous meningitis was a risk factor of false-negative for T-SPOT.TB, while cured TB was a risk factor of false-positive. © 2017 Wiley Periodicals, Inc.

  5. Accuracy and reliability of forensic latent fingerprint decisions.

    PubMed

    Ulery, Bradford T; Hicklin, R Austin; Buscaglia, Joann; Roberts, Maria Antonia

    2011-05-10

    The interpretation of forensic fingerprint evidence relies on the expertise of latent print examiners. The National Research Council of the National Academies and the legal and forensic sciences communities have called for research to measure the accuracy and reliability of latent print examiners' decisions, a challenging and complex problem in need of systematic analysis. Our research is focused on the development of empirical approaches to studying this problem. Here, we report on the first large-scale study of the accuracy and reliability of latent print examiners' decisions, in which 169 latent print examiners each compared approximately 100 pairs of latent and exemplar fingerprints from a pool of 744 pairs. The fingerprints were selected to include a range of attributes and quality encountered in forensic casework, and to be comparable to searches of an automated fingerprint identification system containing more than 58 million subjects. This study evaluated examiners on key decision points in the fingerprint examination process; procedures used operationally include additional safeguards designed to minimize errors. Five examiners made false positive errors for an overall false positive rate of 0.1%. Eighty-five percent of examiners made at least one false negative error for an overall false negative rate of 7.5%. Independent examination of the same comparisons by different participants (analogous to blind verification) was found to detect all false positive errors and the majority of false negative errors in this study. Examiners frequently differed on whether fingerprints were suitable for reaching a conclusion.

  6. [CLINICAL UTILITY OF T-SPOT.TB ASSAY WITH T-Cell Xtend REAGENT FOR ACTIVE TUBERCULOSIS DIAGNOSIS IN THE FIELD TEST AT OUR HOSPITAL].

    PubMed

    Nemoto, Kenji; Oh-ishi, Shuji; Taguchi, Masato; Hyodo, Kentaro; Kanazawa, Jun; Miura, Yukiko; Takaku, Takio; Usui, Shingo; Hayashihara, Kenji; Saito, Takefumi

    2016-04-01

    T-SPOT.TB (T-SPOT), an interferon-gamma release assay, has shown promise as a diagnostic tool for active tuberculosis (TB), and its use is expanding. Addition of the T-Cell Xtend (TCX) reagent may allow delayed processing, and this characteristic is important for using this test in the field. However, limited data is available on the usefulness of T-SPOT with TCX as a field test for diagnosing active TB. To investigate the clinical utility of T-SPOT with TCX and the risk factors for a false-negative result in patients with active TB. A total of 57 patients with active TB who underwent the T-SPOT test with TCX prior to treatment were enrolled between May 2013 and May 2015. One patient with an indeterminate result for T-SPOT was excluded; therefore, the data of 56 patients were eventually included in the final analysis. The basic characteristics and clinical findings were compared between the true-positive and false-negative T-SPOT groups. Of the 56 patients, 40 (71.4%), 13 (23.2%), 3 (5.4%) had true-positive, false-negative, and borderline T-SPOT results, respectively. This study did not reveal any significant risk factors for a false-negative T-SPOT result. In this clinical study, the proportion of patients with a false-negative result for T-SPOT with TCX for active TB was higher than that reported previously. Therefore, careful interpretation of a negative result for T-SPOT with TCX is necessary, regardless of the patient's background.

  7. Accuracy of BRT and Delvotest microbial inhibition tests as affected by composition of ewe's milk.

    PubMed

    Althaus, Rafael; Torres, Antonio; Peris, Cristofol; Beltran, M Carmen; Fernandez, Nemesio; Molina, M Pilar

    2003-03-01

    The presence of drug residues in ewe's milk samples can be determined by microbial assays. The main limitation of these tests is the large number of false-positive results associated with them. False-positive results can be explained by the interaction of certain substances naturally existing in ewe's milk with the growth of the microorganism used in the test. In this study, milk chemical composition (fat, protein, lactose, total solids), somatic cell counts (SCCs), free fatty acid concentrations, and lactoperoxidase system components were determined in order to investigate their influence on the rate of false-positive results for the BRT and Delvotest microbiological inhibitor tests. Milk samples were obtained after morning milking of Manchega ewes at 15, 30, 45, 60, 75, 90, 105, 120, and 135 days after parturition. The animals did not receive any kind of treatment or medicated feed throughout the experiment. The false-positive rates for BRT and Delvotest were 3.75 and 2.4%, respectively. When the logistic regression model was applied, the percentages of total solids for positive samples were significantly different from those for negative samples (16.90 versus 18.42% for BRT, 16.05 versus 18.45% for Delvotest), while the SCC logarithmic transformation was significantly higher for the positive samples than for the negative samples (5.38 versus 5.11 log units for BRT, 5.32 versus 5.11 log units for Delvotest). Moreover, Delvotest-positive samples exhibited thiocyanate concentrations higher than those of Delvotest-negative samples (8.18 mg/liter versus 6.85 mg/liter). Further analyses are needed to confirm the possible presence of antimicrobial residues in this particular type of milk sample.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, James Christopher; Rennie, John Alan; Toevs, James Waldo

    The introduction points out that radiation backgrounds fluctuate across very short distances: factors include geology, soil composition, altitude, building structures, topography, and other manmade structures; and asphalt and concrete can vary significantly over short distances. Brief descriptions are given of the detection system, experimental setup, and background variation measurements. It is concluded that positive and negative gradients can greatly reduce the detection sensitivity of an MDS: negative gradients create opportunities for false negatives (nondetection), and positive gradients create a potentially unacceptable FAR (above 1%); the location of use for mobile detection is important to understand; spectroscopic systems provide more informationmore » for screening out false alarms and may be preferred for mobile use; and mobile monitor testing at LANL accounts for expected variations in the background.« less

  9. A case of placental trisomy 18 mosaicism causing a false negative NIPT result.

    PubMed

    Yang, Jiexia; Qi, Yiming; Guo, Fangfang; Hou, Yaping; Peng, Haishan; Wang, Dongmei; Oy, Haoxin; Yin, Aihua

    2017-01-01

    The non-invasive prenatal testing that evaluates circulating cell free DNA, and has been established as an additional pregnancy test for detecting the common fetal trisomies 21, 18 and 13 is rapidly revolutionizing prenatal screening as a result of its increased sensitivity and specificity. However, false positive and false negative results still exist. We presented a case in which the non-invasive prenatal testing results were normal at 15 gestational age (GA), but an ultrasound examination at 30GA showed that the fetus had heart abnormalities, and the third trimester ultrasound at 33GA noted multiple anomalies including a 3.0 mm ventricular septal defect. Along with cordocentesis at 33GA, the cord blood sample cytogenetics analysis showed a mos 47,XN,+18[61]/46,XN[39] T18 karyotype. Six placental biopsies confirmed that the chromosome 18 placenta chimerism ratio had changed from 33% to 72%. Ultimately, the pregnancy was interrupted at 34GA. We presented this case to highlight the need to clearly explain false positive or false negative results to patients. We believe that this information will also influence the development of future diagnostic test methodologies.

  10. Validation of an Arab name algorithm in the determination of Arab ancestry for use in health research.

    PubMed

    El-Sayed, Abdulrahman M; Lauderdale, Diane S; Galea, Sandro

    2010-12-01

    Data about Arab-Americans, a growing ethnic minority, are not routinely collected in vital statistics, registry, or administrative data in the USA. The difficulty in identifying Arab-Americans using publicly available data sources is a barrier to health research about this group. Here, we validate an empirically based probabilistic Arab name algorithm (ANA) for identifying Arab-Americans in health research. We used data from all Michigan birth certificates between 2000 and 2005. Fathers' surnames and mothers' maiden names were coded as Arab or non-Arab according to the ANA. We calculated sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) of Arab ethnicity inferred using the ANA as compared to self-reported Arab ancestry. Statewide, the ANA had a specificity of 98.9%, a sensitivity of 50.3%, a PPV of 57.0%, and an NPV of 98.6%. Both the false-positive and false-negative rates were higher among men than among women. As the concentration of Arab-Americans in a study locality increased, the ANA false-positive rate increased and false-negative rate decreased. The ANA is highly specific but only moderately sensitive as a means of detecting Arab ancestry. Future research should compare health characteristics among Arab-American populations defined by Arab ancestry and those defined by the ANA.

  11. The power of emotion versus the power of suggestion: memory for emotional events in the misinformation paradigm.

    PubMed

    Van Damme, Ilse; Smets, Karolien

    2014-04-01

    Research has shown that emotional events are remembered better than neutral events, but might also elicit an increase in false memories. The present study was designed to disentangle the influences of valence and arousal on event memory in the misinformation paradigm. Participants were shown six types of photographs (positive with high/low arousal, negative with high/low arousal, ambiguous, neutral), after which half of them were exposed to misleading information. A recognition test assessed memory for both correct and false central and peripheral details. Negative and ambiguous events elicited fewer correct and more false memories for peripheral details than positive and neutral events, regardless of previous exposure to misinformation. Arousal improved memory for correct central details, and both negative valence and arousal inhibited control participants' tendency to endorse false central details. The power of emotion was overruled by the power of suggestion, however, as the latter effect disappeared with previous exposure to misinformation. Results are discussed in the light of earlier research on emotion and cognition, recent motivational theories, and implications for forensic practice.

  12. The efficacy of protoporphyrin as a predictive biomarker for lead exposure in canvasback ducks: effect of sample storage time

    USGS Publications Warehouse

    Franson, J.C.; Hohman, W.L.; Moore, J.L.; Smith, M.R.

    1996-01-01

    We used 363 blood samples collected from wild canvasback dueks (Aythya valisineria) at Catahoula Lake, Louisiana, U.S.A. to evaluate the effect of sample storage time on the efficacy of erythrocytic protoporphyrin as an indicator of lead exposure. The protoporphyrin concentration of each sample was determined by hematofluorometry within 5 min of blood collection and after refrigeration at 4 °C for 24 and 48 h. All samples were analyzed for lead by atomic absorption spectrophotometry. Based on a blood lead concentration of ≥0.2 ppm wet weight as positive evidence for lead exposure, the protoporphyrin technique resulted in overall error rates of 29%, 20%, and 19% and false negative error rates of 47%, 29% and 25% when hematofluorometric determinations were made on blood at 5 min, 24 h, and 48 h, respectively. False positive error rates were less than 10% for all three measurement times. The accuracy of the 24-h erythrocytic protoporphyrin classification of blood samples as positive or negative for lead exposure was significantly greater than the 5-min classification, but no improvement in accuracy was gained when samples were tested at 48 h. The false negative errors were probably due, at least in part, to the lag time between lead exposure and the increase of blood protoporphyrin concentrations. False negatives resulted in an underestimation of the true number of canvasbacks exposed to lead, indicating that hematofluorometry provides a conservative estimate of lead exposure.

  13. Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    PubMed

    Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck

    2015-05-14

    Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false negative results due to seroconversion or misclassification by the lower sensitivity dilution test. Further research is needed to determine if these results can be replicated in other settings. ClinicalTrials.gov, NCT01716299 .

  14. Prime time news: the influence of primed positive and negative emotion on susceptibility to false memories.

    PubMed

    Porter, Stephen; ten Brinke, Leanne; Riley, Sean N; Baker, Alysha

    2014-01-01

    We examined the relation between emotion and susceptibility to misinformation using a novel paradigm, the ambiguous stimuli affective priming (ASAP) paradigm. Participants (N = 88) viewed ambiguous neutral images primed either at encoding or retrieval to be interpreted as either highly positive or negative (or neutral/not primed). After viewing the images, they either were asked misleading or non-leading questions. Following a delay, memory accuracy for the original images was assessed. Results indicated that any emotional priming at encoding led to a higher susceptibility to misinformation relative to priming at recall. In particular, inducing a negative interpretation of the image at encoding led to an increased susceptibility of false memories for major misinformation (an entire object not actually present in the scene). In contrast, this pattern was reversed when priming was used at recall; a negative reinterpretation of the image decreased memory distortion relative to unprimed images. These findings suggest that, with precise experimental control, the experience of emotion at event encoding, in particular, is implicated in false memory susceptibility.

  15. Intellectual factors in false memories of patients with schizophrenia.

    PubMed

    Zhu, Bi; Chen, Chuansheng; Loftus, Elizabeth F; Dong, Qi; Lin, Chongde; Li, Jun

    2018-07-01

    The current study explored the intellectual factors in false memories of 139 patients with schizophrenia, using a recognition task and an IQ test. The full-scale IQ score of the participants ranged from 57 to 144 (M = 100, SD = 14). The full IQ score had a negative correlation with false recognition in patients with schizophrenia, and positive correlations with high-confidence true recognition and discrimination rates. Further analyses with the subtests' scores revealed that false recognition was negatively correlated with scores of performance IQ (and one of its subtests: picture arrangement), whereas true recognition was positively correlated with scores of verbal IQ (and two of its subtests: information and digit span). High-IQ patients had less false recognition (overall or high-confidence false recognition), more high-confidence true recognition, and higher discrimination abilities than those with low IQ. These findings contribute to a better understanding of the cognitive mechanism in false memory of patients with schizophrenia, and are of practical relevance to the evaluation of memory reliability in patients with different intellectual levels. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Assessment of two malaria rapid diagnostic tests in children under five years of age, with follow-up of false-positive pLDH test results, in a hyperendemic falciparum malaria area, Sierra Leone.

    PubMed

    Gerstl, Sibylle; Dunkley, Sophie; Mukhtar, Ahmed; De Smet, Martin; Baker, Samuel; Maikere, Jacob

    2010-01-21

    Most malaria rapid diagnostic tests (RDTs) use HRP2 detection, including Paracheck-Pf(R), but their utility is limited by persistent false positivity after treatment. PLDH-based tests become negative more quickly, but sensitivity has been reported below the recommended standard of 90%. A new pLDH test, CareStart three-line P.f/PAN-pLDH, claims better sensitivity with continued rapid conversion to negative. The study aims were to 1) compare sensitivity and specificity of CareStart to Paracheck-Pf(R) to diagnose falciparum malaria in children under five years of age, 2) assess how quickly false-positive CareStart tests become negative and 3) evaluate ease of use and inter-reader agreement of both tests. Participants were included if they were aged between two and 59 months, presenting to a Médecins Sans Frontières community health centre in eastern Sierra Leone with suspected malaria defined as fever (axillary temperature > 37.5 degrees C) and/or history of fever in the previous 72 hours and no signs of severe disease. The same capillary blood was used for the RDTs and the blood slide, the latter used as the gold standard reference. All positive participants were treated with supervised artesunate and amodiaquine treatment for three days. Participants with a persistent false-positive CareStart, but a negative blood slide on Day 2, were followed with repeated CareStart and blood slide tests every seven days until CareStart became negative or a maximum of 28 days. Sensitivity of CareStart was 99.4% (CI 96.8-100.0, 168/169) and of Paracheck-Pf(R), 98.8% (95% CI 95.8-99.8, 167/169). Specificity of CareStart was 96.0% (CI 91.9-98.4, 167/174) and of Paracheck-Pf(R), 74.7% (CI 67.6-81.0, 130/174) (p < 0.001). Neither test showed any change in sensitivity with decreasing parasitaemia. Of the 155 eligible follow-up CareStart participants, 63.9% (99/155) had a false-positive test on day 2, 21.3% (33/155) on day 7, 5.8% (9/155) on day 14, 1.9% (3/155) on day 21 and 0.6% (1/155) on day 28. The median time for test negativity was seven days. CareStart was as easy to use and interpret as Paracheck-Pf(R) with excellent inter-reader agreement. Both RDTs were highly sensitive, met WHO standards for the detection of falciparum malaria monoinfections where parasitaemia was >100 parasites/mul and were easy to use. CareStart persistent false positivity decreased quickly after successful anti-malarial treatment, making it a good choice for a RDT for a hyperendemic falciparum malaria area.

  17. Assessment of real-time PCR cycle threshold values in Microsporum canis culture-positive and culture-negative cats in an animal shelter: a field study.

    PubMed

    Jacobson, Linda S; McIntyre, Lauren; Mykusz, Jenny

    2018-02-01

    Objectives Real-time PCR provides quantitative information, recorded as the cycle threshold (Ct) value, about the number of organisms detected in a diagnostic sample. The Ct value correlates with the number of copies of the target organism in an inversely proportional and exponential relationship. The aim of the study was to determine whether Ct values could be used to distinguish between culture-positive and culture-negative samples. Methods This was a retrospective analysis of Ct values from dermatophyte PCR results in cats with suspicious skin lesions or suspected exposure to dermatophytosis. Results One hundred and thirty-two samples were included. Using culture as the gold standard, 28 were true positives, 12 were false positives and 92 were true negatives. The area under the curve for the pretreatment time point was 96.8% (95% confidence interval [CI] 94.2-99.5) compared with 74.3% (95% CI 52.6-96.0) for pooled data during treatment. Before treatment, a Ct cut-off of <35.7 (approximate DNA count 300) provided a sensitivity of 92.3% and specificity of 95.2%. There was no reliable cut-off Ct value between culture-positive and culture-negative samples during treatment. Ct values prior to treatment differed significantly between the true-positive and false-positive groups ( P = 0.0056). There was a significant difference between the pretreatment and first and second negative culture time points ( P = 0.0002 and P <0.0001, respectively). However, there was substantial overlap between Ct values for true positives and true negatives, and for pre- and intra-treatment time points. Conclusions and relevance Ct values had limited usefulness for distinguishing between culture-positive and culture-negative cases when field study samples were analyzed. In addition, Ct values were less reliable than fungal culture for determining mycological cure.

  18. In-111 WBC imaging in musculoskeletal sepsis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, L.; Ouzounian, T.J.; Webber, M.M.

    This study evaluated the accuracy and utility of the In-111 labeled WBC imaging in a series of patients who were suspected of having musculoskeletal sepsis. The labeling of the WBCs was patterned after a method previously described, in which the WBCs are labeled with In-111 oxine in plasma. The WBCs from 100 ml of blood are separated and incubated with In-111 oxine complex, and then 500 ..mu..Ci. of the labeled cells were reinjected into the patient. Images of the areas in question were obtained at 24 hrs. In some instances, 48 hour images were also obtained. Images were interpreted usingmore » consistent criteria. Forty imaging procedures were done on 39 patients. These included 39 total joint protheses, and 17 other images to evaluate possible osteomyelitis, septic arthritis or deep abscesses. Of these studies, 15 were positive, and 42 negative. The findings were then correlated with operative culture and pathology in 21, aspiration cultures and gram stains in 14, and with clinical findings in the remaining 21. This correlation showed 41 true negatives, 12 true positives, 1 false negative, and 2 false positives. The sensitivity was 92.9% and the specificity was 95.2%l. The false negative occurred in a patient on chronic suppressive antibiotic therapy for an infected total hip replacement. The false positive images occurred in a patient with active rheumatoid arthritis and in a patient imaged one month post operative placement of the prosthesis. These images were very useful in several septic patients who had many possible sites of infection. The authors conclude that In-III imaging is an accurate and useful non-invasive method of evaluating musculoskeletal sepsis.« less

  19. The Development of Theory of Mind and Positive and Negative Reciprocity in Preschool Children

    PubMed Central

    Schug, Joanna; Takagishi, Haruto; Benech, Catalina; Okada, Hiroyuki

    2016-01-01

    This study examined the relation between the acquisition of false-beliefs theory of mind (ToM) and reciprocity in preschoolers. Preschool-aged children completed a task assessing the understanding of false beliefs, and played an Ultimatum Game (UG) with another child in a face-to-face setting. Negative reciprocity was assessed by examining the rejection of unfair offers made by another child in the UG, while positive reciprocity was assessed by examining allocations made by participants in a Dictator Game (DG) following the UG. The results indicated that children who had passed a task assessing first-order false beliefs were more likely to make generous offers in a DG following a fair offer made by their partner in a proceeding UG, but that false beliefs ToM was unrelated to the rejection of unfair offers in the UG. PMID:27445881

  20. The Development of Theory of Mind and Positive and Negative Reciprocity in Preschool Children.

    PubMed

    Schug, Joanna; Takagishi, Haruto; Benech, Catalina; Okada, Hiroyuki

    2016-01-01

    This study examined the relation between the acquisition of false-beliefs theory of mind (ToM) and reciprocity in preschoolers. Preschool-aged children completed a task assessing the understanding of false beliefs, and played an Ultimatum Game (UG) with another child in a face-to-face setting. Negative reciprocity was assessed by examining the rejection of unfair offers made by another child in the UG, while positive reciprocity was assessed by examining allocations made by participants in a Dictator Game (DG) following the UG. The results indicated that children who had passed a task assessing first-order false beliefs were more likely to make generous offers in a DG following a fair offer made by their partner in a proceeding UG, but that false beliefs ToM was unrelated to the rejection of unfair offers in the UG.

  1. Motivated reconstruction: The effect of brand commitment on false memories.

    PubMed

    Montgomery, Nicole Votolato; Rajagopal, Priyali

    2018-06-01

    Across 5 studies, we examine the effect of prior brand commitment on the creation of false memories about product experience after reading online product reviews. We find that brand commitment and the valence of reviews to which consumers are exposed, interact to affect the incidence of false memories. Thus, highly committed consumers are more susceptible to the creation of false experience memories on exposure to positive versus negative reviews, whereas low commitment consumers exhibit similar levels of false memories in response to both positive and negative reviews. Further, these differences across brand commitment are attenuated when respondents are primed with an accuracy motivation, suggesting that the biasing effects of commitment are likely because of the motivation to defend the committed brand. Finally, we find that differences in false memories subsequently lead to differences in intentions to spread word-of-mouth (e.g., recommend the product to friends), suggesting that the consequences of false product experience memories can be significant for marketers and consumers. Our findings contribute to the literatures in false memory and marketing by documenting a motivated bias in false memories because of brand commitment. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  2. Sensitivity and specificity of intrathecal fluorescein and white light excitation for detecting intraoperative cerebrospinal fluid leak in endoscopic skull base surgery: a prospective study.

    PubMed

    Raza, Shaan M; Banu, Matei A; Donaldson, Angela; Patel, Kunal S; Anand, Vijay K; Schwartz, Theodore H

    2016-03-01

    The intraoperative detection of CSF leaks during endonasal endoscopic skull base surgery is critical to preventing postoperative CSF leaks. Intrathecal fluorescein (ITF) has been used at varying doses to aid in the detection of intraoperative CSF leaks. However, the sensitivity and specificity of ITF at certain dosages is unknown. A prospective database of all endoscopic endonasal procedures was reviewed. All patients received 25 mg ITF diluted in 10 ml CSF and were pretreated with dexamethasone and Benadryl. Immediately after surgery, the operating surgeon prospectively noted if there was an intraoperative CSF leak and fluorescein was identified. The sensitivity, specificity, and positive and negative predictive power of ITF for detecting intraoperative CSF leak were calculated. Factors correlating with postoperative CSF leak were determined. Of 419 patients, 35.8% of patients did not show a CSF leak. Fluorescein-tinted CSF (true positive) was noted in 59.7% of patients and 0 false positives were encountered. CSF without fluorescein staining (false negative) was noted in 4.5% of patients. The sensitivity and specificity of ITF were 92.9% and 100%, respectively. The negative and positive predictive values were 88.8% and 100%, respectively. Postoperative CSF leaks only occurred in true positives at a rate of 2.8%. ITF is extremely specific and very sensitive for detecting intraoperative CSF leaks. Although false negatives can occur, these patients do not appear to be at risk for postoperative CSF leak. The use of ITF may help surgeons prevent postoperative CSF leaks by intraoperatively detecting and confirming a watertight repair.

  3. High false-negative rate of anti-HCV among Egyptian patients on regular hemodialysis.

    PubMed

    El-Sherif, Assem; Elbahrawy, Ashraf; Aboelfotoh, Atef; Abdelkarim, Magdy; Saied Mohammad, Abdel-Gawad; Abdallah, Abdallah Mahmoud; Mostafa, Sadek; Elmestikawy, Amr; Elwassief, Ahmed; Salah, Mohamed; Abdelbaseer, Mohamed Ali; Abdelwahab, Kouka Saadeldin

    2012-07-01

    Routine serological testing for hepatitis C virus (HCV) infection among hemodialysis (HD) patients is currently recommended. A dilemma existed on the value of serology because some investigators reported a high rate of false-negative serologic testing. In this study, we aimed to detect the false-negative rate of anti-HCV among Egyptian HD patients. Seventy-eight HD patients, negative for anti-HCV, anti-HIV, and hepatitis B surface antigen, were tested for HCV RNA by reverse transcriptase polymerase chain reaction (RT-PCR). In the next step, the viral load was quantified by real-time PCR in RT-PCR-positive patients. Risk factors for HCV infection, as well as clinical and biochemical indicators of liver disease, were compared between false-negative and true-negative anti-HCV HD patients. The frequency of false-negative anti-HCV was 17.9%. Frequency of blood transfusion, duration of HD, dialysis at multiple centers, and diabetes mellitus were not identified as risk factors for HCV infection. The frequency of false-negative results had a linear relation to the prevalence of HCV infection in the HD units. Timely identification of HCV within dialysis units is needed in order to lower the risk of HCV spread within the HD units. The high false-negative rate of anti-HCV among HD patients in our study justifies testing of a large scale of patients for precious assessment of effectiveness of nucleic acid amplification technology testing in screening HD patient. © 2012 The Authors. Hemodialysis International © 2012 International Society for Hemodialysis.

  4. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    PubMed

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  5. False-negative and false-positive errors in abdominal pain evaluation: failure to diagnose acute appendicitis and unnecessary surgery.

    PubMed

    Graff, L; Russell, J; Seashore, J; Tate, J; Elwell, A; Prete, M; Werdmann, M; Maag, R; Krivenko, C; Radford, M

    2000-11-01

    To test the hypothesis that physician errors (failure to diagnose appendicitis at initial evaluation) correlate with adverse outcome. The authors also postulated that physician errors would correlate with delays in surgery, delays in surgery would correlate with adverse outcomes, and physician errors would occur on patients with atypical presentations. This was a retrospective two-arm observational cohort study at 12 acute care hospitals: 1) consecutive patients who had an appendectomy for appendicitis and 2) consecutive emergency department abdominal pain patients. Outcome measures were adverse events (perforation, abscess) and physician diagnostic performance (false-positive decisions, false-negative decisions). The appendectomy arm of the study included 1, 026 patients with 110 (10.5%) false-positive decisions (range by hospital 4.7% to 19.5%). Of the 916 patients with appendicitis, 170 (18.6%) false-negative decisions were made (range by hospital 10.6% to 27.8%). Patients who had false-negative decisions had increased risks of perforation (r = 0.59, p = 0.058) and of abscess formation (r = 0.81, p = 0.002). For admitted patients, when the inhospital delay before surgery was >20 hours, the risk of perforation was increased [2.9 odds ratio (OR) 95% CI = 1.8 to 4.8]. The amount of delay from initial physician evaluation until surgery varied with physician diagnostic performance: 7.0 hours (95% CI = 6.7 to 7.4) if the initial physician made the diagnosis, 72.4 hours (95% CI = 51.2 to 93.7) if the initial office physician missed the diagnosis, and 63.1 hours (95% CI = 47.9 to 78.4) if the initial emergency physician missed the diagnosis. Patients whose diagnosis was initially missed by the physician had fewer signs and symptoms of appendicitis than patients whose diagnosis was made initially [appendicitis score 2.0 (95% CI = 1.6 to 2.3) vs 6.5 (95% CI = 6.4 to 6.7)]. Older patients (>41 years old) had more false-negative decisions and a higher risk of perforation or abscess (3.5 OR 95% CI = 2.4 to 5.1). False-positive decisions were made for patients who had signs and symptoms similar to those of appendicitis patients [appendicitis score 5.7 (95% CI = 5.2 to 6.1) vs 6.5 (95% CI = 6.4 to 6.7)]. Female patients had an increased risk of false-positive surgery (2.3 OR 95% CI = 1.5 to 3.4). The abdominal pain arm of the study included 1,118 consecutive patients submitted by eight hospitals, with 44 patients having appendicitis. Hospitals with observation units compared with hospitals without observation units had a higher "rule out appendicitis" evaluation rate [33.7% (95% CI = 27 to 38) vs 24.7% (95% CI = 23 to 27)] and a similar hospital admission rate (27.6% vs 24.7%, p = NS). There was a lower miss-diagnosis rate (15.1% vs 19.4%, p = NS power 0.02), lower perforation rate (19.0% vs 20.6%, p = NS power 0.05), and lower abscess rate (5.6% vs 6.9%, p = NS power 0.06), but these did not reach statistical significance. Errors in physician diagnostic decisions correlated with patient clinical findings, i.e., the missed diagnoses were on appendicitis patients with few clinical findings and unnecessary surgeries were on non-appendicitis patients with clinical findings similar to those of patients with appendicitis. Adverse events (perforation, abscess formation) correlated with physician false-negative decisions.

  6. Experimental layout, data analysis, and thresholds in ELISA testing of maize for aphid-borne viruses.

    PubMed

    Caciagli, P; Verderio, A

    2003-06-30

    Several aspects of enzyme-linked immunosorbent assay (ELISA) procedures and data analysis have been examined in an attempt to find a rapid and reliable method for discriminating between 'positive' and 'negative' results when testing a large number of samples. A layout of ELISA plates was designed to reduce uncontrolled variation and to optimize the number of negative and positive controls. A transformation using the fourth root (A(1/4)) of the optical density readings corrected for the blank (A) stabilized the variance of most ELISA data examined. Transformed A values were used to calculate the true limits, at a set protection level, for false positive (C) and false negative (D). Methods are discussed to reduce the number of undifferentiated samples, i.e. the samples with response falling between C and D. The whole procedure was set up for use with an electronic spreadsheet. With the addition of few instructions of the type 'if em leader then em leader else' in the spreadsheet, the ELISA results were obtained in the simple trichotomous form 'negative/undefined/positive'. This allowed rapid analysis of more than 1100 maize samples testing for the presence of seven aphid-borne viruses-in fact almost 8000 ELISA samples.

  7. Sensitivity and Specificity of Histoplasma Antigen Detection by Enzyme Immunoassay.

    PubMed

    Cunningham, Lauren; Cook, Audrey; Hanzlicek, Andrew; Harkin, Kenneth; Wheat, Joseph; Goad, Carla; Kirsch, Emily

    2015-01-01

    The objective of this study was to evaluate the sensitivity and specificity of an antigen enzyme immunoassay (EIA) on urine samples for the diagnosis of histoplasmosis in dogs. This retrospective medical records review included canine cases with urine samples submitted for Histoplasma EIA antigen assay between 2007 and 2011 from three veterinary institutions. Cases for which urine samples were submitted for Histoplasma antigen testing were reviewed and compared to the gold standard of finding Histoplasma organisms or an alternative diagnosis on cytology or histopathology. Sensitivity, specificity, negative predictive value, positive predictive value, and the kappa coefficient and associated confidence interval were calculated for the EIA-based Histoplasma antigen assay. Sixty cases met the inclusion criteria. Seventeen cases were considered true positives based on identification of the organism, and 41 cases were considered true negatives with an alternative definitive diagnosis. Two cases were considered false negatives, and there were no false positives. Sensitivity was 89.47% and the negative predictive value was 95.35%. Specificity and the positive predictive value were both 100%. The kappa coefficient was 0.9207 (95% confidence interval, 0.8131-1). The Histoplasma antigen EIA test demonstrated high specificity and sensitivity for the diagnosis of histoplasmosis in dogs.

  8. Experimental investigation of observation error in anuran call surveys

    USGS Publications Warehouse

    McClintock, B.T.; Bailey, L.L.; Pollock, K.H.; Simons, T.R.

    2010-01-01

    Occupancy models that account for imperfect detection are often used to monitor anuran and songbird species occurrence. However, presenceabsence data arising from auditory detections may be more prone to observation error (e.g., false-positive detections) than are sampling approaches utilizing physical captures or sightings of individuals. We conducted realistic, replicated field experiments using a remote broadcasting system to simulate simple anuran call surveys and to investigate potential factors affecting observation error in these studies. Distance, time, ambient noise, and observer abilities were the most important factors explaining false-negative detections. Distance and observer ability were the best overall predictors of false-positive errors, but ambient noise and competing species also affected error rates for some species. False-positive errors made up 5 of all positive detections, with individual observers exhibiting false-positive rates between 0.5 and 14. Previous research suggests false-positive errors of these magnitudes would induce substantial positive biases in standard estimators of species occurrence, and we recommend practices to mitigate for false positives when developing occupancy monitoring protocols that rely on auditory detections. These recommendations include additional observer training, limiting the number of target species, and establishing distance and ambient noise thresholds during surveys. ?? 2010 The Wildlife Society.

  9. Expectancy Effects on Self-Reported Attention-Deficit/Hyperactivity Disorder Symptoms in Simulated Neurofeedback: A Pilot Study.

    PubMed

    Lee, Grace J; Suhr, Julie A

    2018-03-31

    Expectancy is a psychological factor that can impact treatment effectiveness. Research on neurofeedback for attention-deficit/hyperactivity disorder (ADHD) suggests expectancy may contribute to treatment outcomes, though evidence for expectancy as an explanatory factor is sparse. This pilot study investigated the effects of expectancies on self-reported ADHD symptoms in simulated neurofeedback. Forty-six adults who were concerned that they had ADHD expected to receive active neurofeedback, but were randomly assigned to receive a placebo with false feedback indicating attentive (positive false feedback) or inattentive (negative false feedback) states. Effects of the expectancy manipulation were measured on an ADHD self-report scale. Large expectancy effects were found, such that individuals who received positive false feedback reported significant decreases in ADHD symptoms, whereas individuals who received negative false feedback reported significant increases in ADHD symptoms. Findings suggest that expectancy should be considered as an explanatory mechanism for ADHD symptom change in response to neurofeedback.

  10. There was not, they did not: May negation cause the negated ideas to be remembered as existing?

    PubMed Central

    2017-01-01

    In this article we demonstrate that negation of ideas can have paradoxical effects, possibly leading the listener to believe that the negated ideas actually existed. In Experiment 1, participants listened to a description of a house, in which some objects were mentioned, some were negated, and some were not mentioned at all. When questioned about the existence of these objects a week later, the participants gave more false positives for items that were negated in the original material than for items that were not mentioned at all, an effect we call negation related false memories (NRFM). The NRFM effect was replicated again in Experiment 2 with a sample of five and six year-old children. Experiment 3 confirmed NRFM in the case of negated actions. The results are discussed in terms of retention hypothesis, as well as the theory that negation can activate a representation of an entity and behaviour. It is also indicated that future research is needed to ensure that it is indeed negation which caused false alarms, not merely mentioning an object. PMID:28448549

  11. True negative predictive value of endobronchial ultrasound in lung cancer: are we being conservative enough?

    PubMed

    Whitson, Bryan A; Groth, Shawn S; Odell, David D; Briones, Eleazar P; Maddaus, Michael A; D'Cunha, Jonathan; Andrade, Rafael S

    2013-05-01

    Mediastinal staging in patients with non-small cell lung cancer (NSCLC) with endobronchial ultrasound-guided fine-needle aspiration (EBUS-FNA) requires a high negative predictive value (NPV) (ie, low false negative rate). We provide a conservative calculation of NPV that calls for caution in the interpretation of EBUS results. We retrospectively analyzed our prospectively gathered database (January 2007 to November 2011) to include NSCLC patients who underwent EBUS-FNA for mediastinal staging. We excluded patients with metastatic NSCLC and other malignancies. We assessed FNAs with rapid on-site evaluation (ROSE). The calculation of NPV is NPV = true negatives/true negatives + false negatives. However, this definition ignores nondiagnostic samples. Nondiagnostic samples should be added to the NPV denominator because decisions based on nondiagnostic samples could be flawed. We conservatively calculated NPV for EBUS-FNA as NPV = true negatives/true negatives + false negatives + nondiagnostic. We defined false negatives as negative FNAs but NSCLC-positive surgical biopsy of the same site. Nondiagnostic FNAs were nonrepresentative of lymphoid tissue. We compared diagnostic performance with the inclusion and exclusion of nondiagnostic procedures. We studied 120 patients with NSCLC who underwent EBUS-FNA; 5 patients had false negative findings and 10 additional patients had nondiagnostic results. The NPV with and without inclusion of nondiagnostic samples was 65.9% and 85.3%, respectively. The inclusion of nondiagnostic specimens into the conservative, worst-case-scenario calculation of NPV for EBUS-FNA in NSCLC lowers the NPV from 85.3% to 65.9%. The true NPV is likely higher than 65.9% as few nondiagnostic specimens are false negatives. Caution is imperative for the safe application of EBUS-FNA in NSCLC staging. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Gene expression information improves reliability of receptor status in breast cancer patients

    PubMed Central

    Kenn, Michael; Schlangen, Karin; Castillo-Tong, Dan Cacsire; Singer, Christian F.; Cibena, Michael; Koelbl, Heinz; Schreiner, Wolfgang

    2017-01-01

    Immunohistochemical (IHC) determination of receptor status in breast cancer patients is frequently inaccurate. Since it directs the choice of systemic therapy, it is essential to increase its reliability. We increase the validity of IHC receptor expression by additionally considering gene expression (GE) measurements. Crisp therapeutic decisions are based on IHC estimates, even if they are borderline reliable. We further improve decision quality by a responsibility function, defining a critical domain for gene expression. Refined normalization is devised to file any newly diagnosed patient into existing data bases. Our approach renders receptor estimates more reliable by identifying patients with questionable receptor status. The approach is also more efficient since the rate of conclusive samples is increased. We have curated and evaluated gene expression data, together with clinical information, from 2880 breast cancer patients. Combining IHC with gene expression information yields a method more reliable and also more efficient as compared to common practice up to now. Several types of possibly suboptimal treatment allocations, based on IHC receptor status alone, are enumerated. A ‘therapy allocation check’ identifies patients possibly miss-classified. Estrogen: false negative 8%, false positive 6%. Progesterone: false negative 14%, false positive 11%. HER2: false negative 2%, false positive 50%. Possible implications are discussed. We propose an ‘expression look-up-plot’, allowing for a significant potential to improve the quality of precision medicine. Methods are developed and exemplified here for breast cancer patients, but they may readily be transferred to diagnostic data relevant for therapeutic decisions in other fields of oncology. PMID:29100391

  13. Emotionally Negative Pictures Enhance Gist Memory

    PubMed Central

    Bookbinder, S. H.; Brainerd, C. J.

    2016-01-01

    In prior work on how true and false memory are influenced by emotion, valence and arousal have often been conflated. Thus, it is difficult to say which specific effects are due to valence and which are due to arousal. In the present research, we used a picture-memory paradigm that allowed emotional valence to be manipulated with arousal held constant. Negatively-valenced pictures elevated both true and false memory, relative to positive and neutral pictures. Conjoint recognition modeling revealed that negative valence (a) reduced erroneous suppression of true memories and (b) increased the familiarity of the semantic content of both true and false memories. Overall, negative valence impaired the verbatim side of episodic memory but enhanced the gist side, and these effects persisted even after a week-long delay. PMID:27454002

  14. Imaging in gynaecology: How good are we in identifying endometriomas?

    PubMed Central

    Van Holsbeke, C.; Van Calster, B.; Guerriero, S.; Savelli, L.; Leone, F.; Fischerova, D; Czekierdowski, A.; Fruscio, R.; Veldman, J.; Van de Putte, G.; Testa, A.C.; Bourne, T.; Valentin, L.; Timmerman, D.

    2009-01-01

    Aim: To evaluate the performance of subjective evaluation of ultrasound findings (pattern recognition) to discriminate endometriomas from other types of adnexal masses and to compare the demographic and ultrasound characteristics of the true positive cases with those cases that were presumed to be an endometrioma but proved to have a different histology (false positive cases) and the endometriomas missed by pattern recognition (false negative cases). Methods: All patients in the International Ovarian Tumor Analysis (IOTA ) studies were included for analysis. In the IOTA studies, patients with an adnexal mass that were preoperatively examined by expert sonologists following the same standardized ultrasound protocol were prospectively included in 21 international centres. Sensitivity and specificity to discriminate endometriomas from other types of adnexal masses using pattern recognition were calculated. Ultrasound and some demographic variables of the masses presumed to be an endometrioma were analysed (true positives and false positives) and compared with the variables of the endometriomas missed by pattern recognition (false negatives) as well as the true negatives. Results: IOTA phase 1, 1b and 2 included 3511 patients of which 2560 were benign (73%) and 951 malignant (27%). The dataset included 713 endometriomas. Sensitivity and specificity for pattern recognition were 81% (577/713) and 97% (2723/2798). The true positives were more often unilocular with ground glass echogenicity than the masses in any other category. Among the 75 false positive cases, 66 were benign but 9 were malignant (5 borderline tumours, 1 rare primary invasive tumour and 3 endometrioid adenocarcinomas). The presumed diagnosis suggested by the sonologist in case of a missed endometrioma was mostly functional cyst or cystadenoma. Conclusion: Expert sonologists can quite accurately discriminate endometriomas from other types of adnexal masses, but in this dataset 1% of the masses that were classified as endometrioma by pattern recognition proved to be malignancies. PMID:25478066

  15. Performance of a semi-quantitative whole blood test for human heart-type fatty acid-binding protein (H-FABP).

    PubMed

    Hiura, Masahito; Nakajima, Osamu; Mori, Toshizumi; Kitano, Katsuya

    2005-10-01

    We evaluated the accuracy of visually reading the whole blood Rapicheck H-FABP panel test using the quantitative plasma H-FABP concentration as the reference. Consecutive patients with chest pain (n = 237) who were suspected of having acute myocardial infarction were recruited. The appearance of an evident test line within 5 min was given a grade of +3 (strongly positive), appearance within 15 min +2 (moderately positive) and the appearance of a weak test line within 15 min +1 (weakly positive). The concordance rates were 91.8% for positive, 70.1% for negative and 80.2% for overall. Plasma H-FABP concentrations were above the cut-off value for 9.2% of negative (0) results. Fifty percent of weakly positive (+1) and 25.0% of moderately positive (+2) results had H-FABP concentrations lower than the cut-off value. All of the strongly positive (+3) were above the cut-off value. These results suggested that the false-positive and false-negative results of Rapicheck H-FABP were caused by over or underestimation in visual reading when the plasma H-FABP concentration was near the cut-off concentration. Low accuracy of visual reading of Rapicheck H-FABP was due to poor estimation by manual reading around the cut-off value.

  16. Development and Implementation of Metrics for Identifying Military Impulse Noise

    DTIC Science & Technology

    2010-09-01

    False Negative Rate FP False Positive FPR False Positive Rate FtC Fort Carson, CO GIS Geographic Information System GMM Gaussian mixture model Hz...60 70 80 90 100 110 Bin Number B in N um be r N um ber of D ata Points M apped to B in 14 Figure 8. Plot of typical neuron activation...signal metrics and waveform itself were saved and transmitted to the home base. There is also a provision to download the entire recorded waveform

  17. Multilingual vocal emotion recognition and classification using back propagation neural network

    NASA Astrophysics Data System (ADS)

    Kayal, Apoorva J.; Nirmal, Jagannath

    2016-03-01

    This work implements classification of different emotions in different languages using Artificial Neural Networks (ANN). Mel Frequency Cepstral Coefficients (MFCC) and Short Term Energy (STE) have been considered for creation of feature set. An emotional speech corpus consisting of 30 acted utterances per emotion has been developed. The emotions portrayed in this work are Anger, Joy and Neutral in each of English, Marathi and Hindi languages. Different configurations of Artificial Neural Networks have been employed for classification purposes. The performance of the classifiers has been evaluated by False Negative Rate (FNR), False Positive Rate (FPR), True Positive Rate (TPR) and True Negative Rate (TNR).

  18. Influence of ECG measurement accuracy on ECG diagnostic statements.

    PubMed

    Zywietz, C; Celikag, D; Joseph, G

    1996-01-01

    Computer analysis of electrocardiograms (ECGs) provides a large amount of ECG measurement data, which may be used for diagnostic classification and storage in ECG databases. Until now, neither error limits for ECG measurements have been specified nor has their influence on diagnostic statements been systematically investigated. An analytical method is presented to estimate the influence of measurement errors on the accuracy of diagnostic ECG statements. Systematic (offset) errors will usually result in an increase of false positive or false negative statements since they cause a shift of the working point on the receiver operating characteristics curve. Measurement error dispersion broadens the distribution function of discriminative measurement parameters and, therefore, usually increases the overlap between discriminative parameters. This results in a flattening of the receiver operating characteristics curve and an increase of false positive and false negative classifications. The method developed has been applied to ECG conduction defect diagnoses by using the proposed International Electrotechnical Commission's interval measurement tolerance limits. These limits appear too large because more than 30% of false positive atrial conduction defect statements and 10-18% of false intraventricular conduction defect statements could be expected due to tolerated measurement errors. To assure long-term usability of ECG measurement databases, it is recommended that systems provide its error tolerance limits obtained on a defined test set.

  19. Avoiding false positive antigen detection by flow cytometry on blood cell derived microparticles: the importance of an appropriate negative control.

    PubMed

    Crompot, Emerence; Van Damme, Michael; Duvillier, Hugues; Pieters, Karlien; Vermeesch, Marjorie; Perez-Morga, David; Meuleman, Nathalie; Mineur, Philippe; Bron, Dominique; Lagneaux, Laurence; Stamatopoulos, Basile

    2015-01-01

    Microparticles (MPs), also called microvesicles (MVs) are plasma membrane-derived fragments with sizes ranging from 0.1 to 1μm. Characterization of these MPs is often performed by flow cytometry but there is no consensus on the appropriate negative control to use that can lead to false positive results. We analyzed MPs from platelets, B-cells, T-cells, NK-cells, monocytes, and chronic lymphocytic leukemia (CLL) B-cells. Cells were purified by positive magnetic-separation and cultured for 48h. Cells and MPs were characterized using the following monoclonal antibodies (CD19,20 for B-cells, CD3,8,5,27 for T-cells, CD16,56 for NK-cells, CD14,11c for monocytes, CD41,61 for platelets). Isolated MPs were stained with annexin-V-FITC and gated between 300nm and 900nm. The latex bead technique was then performed for easy detection of MPs. Samples were analyzed by Transmission (TEM) and Scanning Electron microscopy (SEM). Annexin-V positive events within a gate of 300-900nm were detected and defined as MPs. Our results confirmed that the characteristic antigens CD41/CD61 were found on platelet-derived-MPs validating our technique. However, for MPs derived from other cell types, we were unable to detect any antigen, although they were clearly expressed on the MP-producing cells in the contrary of several data published in the literature. Using the latex bead technique, we confirmed detection of CD41,61. However, the apparent expression of other antigens (already deemed positive in several studies) was determined to be false positive, indicated by negative controls (same labeling was used on MPs from different origins). We observed that mother cell antigens were not always detected on corresponding MPs by direct flow cytometry or latex bead cytometry. Our data highlighted that false positive results could be generated due to antibody aspecificity and that phenotypic characterization of MPs is a difficult field requiring the use of several negative controls.

  20. Avoiding False Positive Antigen Detection by Flow Cytometry on Blood Cell Derived Microparticles: The Importance of an Appropriate Negative Control

    PubMed Central

    Crompot, Emerence; Van Damme, Michael; Duvillier, Hugues; Pieters, Karlien; Vermeesch, Marjorie; Perez-Morga, David; Meuleman, Nathalie; Mineur, Philippe; Bron, Dominique; Lagneaux, Laurence; Stamatopoulos, Basile

    2015-01-01

    Background Microparticles (MPs), also called microvesicles (MVs) are plasma membrane-derived fragments with sizes ranging from 0.1 to 1μm. Characterization of these MPs is often performed by flow cytometry but there is no consensus on the appropriate negative control to use that can lead to false positive results. Materials and Methods We analyzed MPs from platelets, B-cells, T-cells, NK-cells, monocytes, and chronic lymphocytic leukemia (CLL) B-cells. Cells were purified by positive magnetic-separation and cultured for 48h. Cells and MPs were characterized using the following monoclonal antibodies (CD19,20 for B-cells, CD3,8,5,27 for T-cells, CD16,56 for NK-cells, CD14,11c for monocytes, CD41,61 for platelets). Isolated MPs were stained with annexin-V-FITC and gated between 300nm and 900nm. The latex bead technique was then performed for easy detection of MPs. Samples were analyzed by Transmission (TEM) and Scanning Electron microscopy (SEM). Results Annexin-V positive events within a gate of 300-900nm were detected and defined as MPs. Our results confirmed that the characteristic antigens CD41/CD61 were found on platelet-derived-MPs validating our technique. However, for MPs derived from other cell types, we were unable to detect any antigen, although they were clearly expressed on the MP-producing cells in the contrary of several data published in the literature. Using the latex bead technique, we confirmed detection of CD41,61. However, the apparent expression of other antigens (already deemed positive in several studies) was determined to be false positive, indicated by negative controls (same labeling was used on MPs from different origins). Conclusion We observed that mother cell antigens were not always detected on corresponding MPs by direct flow cytometry or latex bead cytometry. Our data highlighted that false positive results could be generated due to antibody aspecificity and that phenotypic characterization of MPs is a difficult field requiring the use of several negative controls. PMID:25978814

  1. Efficacy of 67 gallium ECT imaging in lymphoma, infection, and lung carcinoma: A comparison with planar imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harwood, S.J.; Anderson, M.W.; Klein, R.C.

    1984-01-01

    Emission computed tomography (ECT) studies were performed on a GE 400 A/T camera and ADAC computers (system 3 and system 3300). Thirty-three sets of ECT and planar images were obtained in 20 patients over a six month period. Imaging was performed 48 hours after the intravenous administration of 5 mc of Gallium 67 citrate. No bowel preparation was employed. Comparison is made of the initial nuclear medicine report derived from planar and ECT imaging aided by clinical knowledge versus the consensus opinion of two nuclear medicine physicians reading the planar images along with minimal clinical information. The lymphoma series consistsmore » of 18 scans in 10 patients. There were 5 scans in which a false negative planar interpretation was changed to a true positive ECT interpretation. Sensitivity of planar imaging for lymphoma was 58% which rose to 100% with addition of ECT information. There were no false positives by either technique. There were 5 sets of scans in 5 lung carcinoma patients. Sensitivity of the planar images was 60% because of 2 false negative results. Sensitivity of the ECT technique was 100%. There were no false positives. The infection series consists of 10 scans in 5 patients. Sensitivity of ECT was 100%, sensitivity of planar was 66%. There was 1 false positive planar. For the total series the accuracy of planar imaging was 69% and the predictive value of a negative planar interpretation was 44%. Corresponding values for ECT imaging were 100%. The authors' experience demonstrates significant increase in sensitivity without loss of specificity resulting from the use of Emission Computed Tomography in both chest and abdomen in patients with lymphoma, infection, and lung cancer.« less

  2. Is there a positive bias in false recognition? Evidence from confabulating amnesia patients.

    PubMed

    Alkathiri, Nura H; Morris, Robin G; Kopelman, Michael D

    2015-10-01

    Although there is some evidence for a positive emotional bias in the content of confabulations in brain damaged patients, findings have been inconsistent. The present study used the semantic-associates procedure to induce false recall and false recognition in order to examine whether a positive bias would be found in confabulating amnesic patients, relative to non-confabulating amnesic patients and healthy controls. Lists of positive, negative and neutral words were presented in order to induce false recall or false recognition of non-presented (but semantically associated) words. The latter were termed 'critical intrusions'. Thirteen confabulating amnesic patients, 13 non-confabulating amnesic patients and 13 healthy controls were investigated. Confabulating patients falsely recognised a higher proportion of positive (but unrelated) words, compared with non-confabulating patients and healthy controls. No differences were found for recall memory. Signal detection analysis, however, indicated that the positive bias for false recognition memory might reflect weaker memory in the confabulating amnesic group. This suggested that amnesia patients with weaker memory are more likely to confabulate and the content of these confabulations are more likely to be positive. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. False-Positive Cryptococcal Antigen Test Associated with Use of BBL Port-A-Cul Transport Vials▿

    PubMed Central

    Wilson, Deborah A.; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S.; Procop, Gary W.

    2011-01-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed. PMID:21159939

  4. False-positive cryptococcal antigen test associated with use of BBL Port-a-Cul transport vials.

    PubMed

    Wilson, Deborah A; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S; Procop, Gary W

    2011-02-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed.

  5. False-negative malaria rapid diagnostic tests in Rwanda: impact of Plasmodium falciparum isolates lacking hrp2 and declining malaria transmission.

    PubMed

    Kozycki, Christina T; Umulisa, Noella; Rulisa, Stephen; Mwikarago, Emil I; Musabyimana, Jean Pierre; Habimana, Jean Pierre; Karema, Corine; Krogstad, Donald J

    2017-03-20

    Rapid diagnostic tests (RDTs) for histidine rich protein 2 (HRP2) are often used to determine whether persons with fever should be treated with anti-malarials. However, Plasmodium falciparum parasites with a deletion of the hrp2 gene yield false-negative RDTs and there are concerns the sensitivity of HRP2-based RDTs may fall when the intensity of transmission decreases. This observational study enrolled 9226 patients at three health centres in Rwanda from April 2014 to April 2015. It then compared the sensitivity of RDTs based on HRP2 and the Plasmodium lactate dehydrogenase (pLDH) to microscopy (thick smears) for the diagnosis of malaria. PCR was used to determine whether deletions of the histidine-rich central repeat region of the hrp2 gene (exon 2) were associated with false-negative HRP2-based RDTs. In comparison to microscopy, the sensitivity and specificity of HRP2- and pLDH-based RDTs were 89.5 and 86.2% and 80.2 and 94.3%, respectively. When the results for both RDTs were combined, sensitivity rose to 91.8% and specificity was 85.7%. Additionally, when smear positivity fell from 46 to 3%, the sensitivity of the HRP2-based RDT fell from 88 to 67%. Of 370 samples with false-negative HRP2 RDT results for which PCR was performed, 140 (38%) were identified as P. falciparum by PCR. Of the isolates identified as P. falciparum by PCR, 32 (23%) were negative for the hrp2 gene based on PCR. Of the 32 P. falciparum isolates negative for hrp2 by PCR, 17 (53%) were positive based on the pLDH RDT. This prospective study of RDT performance coincided with a decline in the intensity of malaria transmission in Kibirizi (fall in slide positivity from 46 to 3%). This decline was associated with a decrease in HRP2 RDT sensitivity (from 88 to 67%). While P. falciparum isolates without the hrp2 gene were an important cause of false-negative HRP2-based RDTs, most were identified by the pLDH-based RDT. Although WHO does not recommend the use of combined HRP2/pLDH testing in sub-Saharan Africa, these results suggest that combination HRP2/pLDH-based RDTs could reduce the impact of false-negative HRP2-based RDTs for detection of symptomatic P. falciparum malaria.

  6. Robotic CCD microscope for enhanced crystal recognition

    DOEpatents

    Segelke, Brent W.; Toppani, Dominique

    2007-11-06

    A robotic CCD microscope and procedures to automate crystal recognition. The robotic CCD microscope and procedures enables more accurate crystal recognition, leading to fewer false negative and fewer false positives, and enable detection of smaller crystals compared to other methods available today.

  7. Comparison of one-tier and two-tier newborn screening metrics for congenital adrenal hyperplasia.

    PubMed

    Sarafoglou, Kyriakie; Banks, Kathryn; Gaviglio, Amy; Hietala, Amy; McCann, Mark; Thomas, William

    2012-11-01

    Newborn screening (NBS) for the classic forms of congenital adrenal hyperplasia (CAH) is mandated in all states in the United States. Compared with other NBS disorders, the false-positive rate (FPR) of CAH screening remains high and has not been significantly improved by adjusting 17α-hydroxyprogesterone cutoff values for birth weight and/or gestational age. Minnesota was the first state to initiate, and only 1 of 4 states currently performing, second-tier steroid profiling for CAH. False-negative rates (FNRs) for CAH are not well known. This is a population-based study of all Minnesota infants (769,834) born 1999-2009, grouped by screening protocol (one-tier with repeat screen, January 1999 to May 2004; two-tier with second-tier steroid profiling, June 2004 to December 2009). FPR, FNR, and positive predictive value (PPV) were calculated per infant, rather than per sample, and compared between protocols. Overall, 15 false-negatives (4 salt-wasting, 11 simple-virilizing) and 45 true-positives were identified from 1999 to 2009. With two-tier screening, FNR was 32%, FPR increased to 0.065%, and PPV decreased to 8%, but these changes were not statistically significant. Second-tier steroid profiling obviated repeat screens of borderline results (355 per year average). In comparing the 2 screening protocols, the FPR of CAH NBS remains high, the PPV remains low, and false-negatives occur more frequently than has been reported. Physicians should be cautioned that a negative NBS does not necessarily rule out classic CAH; therefore, any patient for whom there is clinical concern for CAH should receive immediate diagnostic testing.

  8. False negative PCR despite high levels of JC virus DNA in spinal fluid: Implications for diagnostic testing

    PubMed Central

    Landry, Marie L.; Eid, Tore; Bannykh, Serguei; Major, Eugene

    2009-01-01

    Genome amplification methods such as polymerase chain reaction (PCR) have revolutionized our ability to detect viruses in spinal fluids of patients with neurologic diseases. It is not as well appreciated among clinicians that PCR protocols, quality assurance, and technical expertise vary significantly among laboratories. In a multi-laboratory blinded study of herpes simplex virus PCR, the most widely used and best validated CSF PCR assay, low-level positives were often missed and false positives were not uncommon [Schloss L, van Loon AM, Cinque P, Cleator G, Echevarria JM, Falk KI, et al. An international external quality assessment of nucleic acid amplification of herpes simplex virus. J Clin Virol 2003;28(2):175–85]. In addition, genome variability and mutations, which are increasingly recognized for a number of different viruses, can lead to falsely low or negative results. Both clinicians and laboratories must recognize the limitations of PCR, since misleading results may have serious consequences. We present here a case of a rapidly progressive, fatal neurologic illness in a young mother, whose CSF JCV DNA PCR at a reference laboratory was falsely negative. Ultimately, brain biopsy established the diagnosis of progressive multifocal leukoencephalopathy (PML). Repeat PCR testing of the same CSF targeting a different region of the genome yielded a high positive result. PMID:18701345

  9. Validation of an Arab names algorithm in the determination of Arab ancestry for use in health research

    PubMed Central

    El-Sayed, Abdulrahman M.; Lauderdale, Diane S.; Galea, Sandro

    2010-01-01

    Objective Data about Arab-Americans, a growing ethnic minority, is not routinely collected in vital statistics, registry, or administrative data in the US. The difficulty in identifying Arab-Americans using publicly available data sources is a barrier to health research about this group. Here, we validate an empirically-based, probabilistic Arab name algorithm (ANA) for identifying Arab-Americans in health research. Design We used data from all Michigan birth certificates between 2000-2005. Fathers’ surnames and mothers’ maiden names were coded as Arab or non-Arab according to the ANA. We calculated sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) of Arab ethnicity inferred using the ANA as compared to self-reported Arab ancestry. Results State-wide, the ANA had a specificity of 98.9%, a sensitivity of 50.3%, a PPV of 57.0%, and a NPV of 98.6%. Both the false positive and false negative rates were higher among men than among women. As the concentration of Arab-Americans in a study locality increased, the ANA false positive rate increased and false-negative rate decreased. Conclusion The ANA is highly specific but only moderately sensitive as a means of detecting Arab ancestry. Future research should compare health characteristics among Arab-American populations defined by Arab ancestry and those defined by the ANA. PMID:20845117

  10. Underpowered samples, false negatives, and unconscious learning.

    PubMed

    Vadillo, Miguel A; Konstantinidis, Emmanouil; Shanks, David R

    2016-02-01

    The scientific community has witnessed growing concern about the high rate of false positives and unreliable results within the psychological literature, but the harmful impact of false negatives has been largely ignored. False negatives are particularly concerning in research areas where demonstrating the absence of an effect is crucial, such as studies of unconscious or implicit processing. Research on implicit processes seeks evidence of above-chance performance on some implicit behavioral measure at the same time as chance-level performance (that is, a null result) on an explicit measure of awareness. A systematic review of 73 studies of contextual cuing, a popular implicit learning paradigm, involving 181 statistical analyses of awareness tests, reveals how underpowered studies can lead to failure to reject a false null hypothesis. Among the studies that reported sufficient information, the meta-analytic effect size across awareness tests was d z = 0.31 (95 % CI 0.24-0.37), showing that participants' learning in these experiments was conscious. The unusually large number of positive results in this literature cannot be explained by selective publication. Instead, our analyses demonstrate that these tests are typically insensitive and underpowered to detect medium to small, but true, effects in awareness tests. These findings challenge a widespread and theoretically important claim about the extent of unconscious human cognition.

  11. Reduction of false-positives in a CAD scheme for automated detection of architectural distortion in digital mammography

    NASA Astrophysics Data System (ADS)

    de Oliveira, Helder C. R.; Mencattini, Arianna; Casti, Paola; Martinelli, Eugenio; di Natale, Corrado; Catani, Juliana H.; de Barros, Nestor; Melo, Carlos F. E.; Gonzaga, Adilson; Vieira, Marcelo A. C.

    2018-02-01

    This paper proposes a method to reduce the number of false-positives (FP) in a computer-aided detection (CAD) scheme for automated detection of architectural distortion (AD) in digital mammography. AD is a subtle contraction of breast parenchyma that may represent an early sign of breast cancer. Due to its subtlety and variability, AD is more difficult to detect compared to microcalcifications and masses, and is commonly found in retrospective evaluations of false-negative mammograms. Several computer-based systems have been proposed for automated detection of AD in breast images. The usual approach is automatically detect possible sites of AD in a mammographic image (segmentation step) and then use a classifier to eliminate the false-positives and identify the suspicious regions (classification step). This paper focus on the optimization of the segmentation step to reduce the number of FPs that is used as input to the classifier. The proposal is to use statistical measurements to score the segmented regions and then apply a threshold to select a small quantity of regions that should be submitted to the classification step, improving the detection performance of a CAD scheme. We evaluated 12 image features to score and select suspicious regions of 74 clinical Full-Field Digital Mammography (FFDM). All images in this dataset contained at least one region with AD previously marked by an expert radiologist. The results showed that the proposed method can reduce the false positives of the segmentation step of the CAD scheme from 43.4 false positives (FP) per image to 34.5 FP per image, without increasing the number of false negatives.

  12. Determining Occurrence Dynamics when False Positives Occur: Estimating the Range Dynamics of Wolves from Public Survey Data.

    PubMed

    Miller, David A W; Nichols, James D; Gude, Justin A; Rich, Lindsey N; Podruzny, Kevin M; Hines, James E; Mitchell, Michael S

    2013-01-01

    Large-scale presence-absence monitoring programs have great promise for many conservation applications. Their value can be limited by potential incorrect inferences owing to observational errors, especially when data are collected by the public. To combat this, previous analytical methods have focused on addressing non-detection from public survey data. Misclassification errors have received less attention but are also likely to be a common component of public surveys, as well as many other data types. We derive estimators for dynamic occupancy parameters (extinction and colonization), focusing on the case where certainty can be assumed for a subset of detections. We demonstrate how to simultaneously account for non-detection (false negatives) and misclassification (false positives) when estimating occurrence parameters for gray wolves in northern Montana from 2007-2010. Our primary data source for the analysis was observations by deer and elk hunters, reported as part of the state's annual hunter survey. This data was supplemented with data from known locations of radio-collared wolves. We found that occupancy was relatively stable during the years of the study and wolves were largely restricted to the highest quality habitats in the study area. Transitions in the occupancy status of sites were rare, as occupied sites almost always remained occupied and unoccupied sites remained unoccupied. Failing to account for false positives led to over estimation of both the area inhabited by wolves and the frequency of turnover. The ability to properly account for both false negatives and false positives is an important step to improve inferences for conservation from large-scale public surveys. The approach we propose will improve our understanding of the status of wolf populations and is relevant to many other data types where false positives are a component of observations.

  13. Unmodeled observation error induces bias when inferring patterns and dynamics of species occurrence via aural detections

    USGS Publications Warehouse

    McClintock, Brett T.; Bailey, Larissa L.; Pollock, Kenneth H.; Simons, Theodore R.

    2010-01-01

    The recent surge in the development and application of species occurrence models has been associated with an acknowledgment among ecologists that species are detected imperfectly due to observation error. Standard models now allow unbiased estimation of occupancy probability when false negative detections occur, but this is conditional on no false positive detections and sufficient incorporation of explanatory variables for the false negative detection process. These assumptions are likely reasonable in many circumstances, but there is mounting evidence that false positive errors and detection probability heterogeneity may be much more prevalent in studies relying on auditory cues for species detection (e.g., songbird or calling amphibian surveys). We used field survey data from a simulated calling anuran system of known occupancy state to investigate the biases induced by these errors in dynamic models of species occurrence. Despite the participation of expert observers in simplified field conditions, both false positive errors and site detection probability heterogeneity were extensive for most species in the survey. We found that even low levels of false positive errors, constituting as little as 1% of all detections, can cause severe overestimation of site occupancy, colonization, and local extinction probabilities. Further, unmodeled detection probability heterogeneity induced substantial underestimation of occupancy and overestimation of colonization and local extinction probabilities. Completely spurious relationships between species occurrence and explanatory variables were also found. Such misleading inferences would likely have deleterious implications for conservation and management programs. We contend that all forms of observation error, including false positive errors and heterogeneous detection probabilities, must be incorporated into the estimation framework to facilitate reliable inferences about occupancy and its associated vital rate parameters.

  14. Best research practices in psychology: Illustrating epistemological and pragmatic considerations with the case of relationship science.

    PubMed

    Finkel, Eli J; Eastwick, Paul W; Reis, Harry T

    2015-02-01

    In recent years, a robust movement has emerged within psychology to increase the evidentiary value of our science. This movement, which has analogs throughout the empirical sciences, is broad and diverse, but its primary emphasis has been on the reduction of statistical false positives. The present article addresses epistemological and pragmatic issues that we, as a field, must consider as we seek to maximize the scientific value of this movement. Regarding epistemology, this article contrasts the false-positives-reduction (FPR) approach with an alternative, the error balance (EB) approach, which argues that any serious consideration of optimal scientific practice must contend simultaneously with both false-positive and false-negative errors. Regarding pragmatics, the movement has devoted a great deal of attention to issues that frequently arise in laboratory experiments and one-shot survey studies, but it has devoted less attention to issues that frequently arise in intensive and/or longitudinal studies. We illustrate these epistemological and pragmatic considerations with the case of relationship science, one of the many research domains that frequently employ intensive and/or longitudinal methods. Specifically, we examine 6 research prescriptions that can help to reduce false-positive rates: preregistration, prepublication sharing of materials, postpublication sharing of data, close replication, avoiding piecemeal publication, and increasing sample size. For each, we offer concrete guidance not only regarding how researchers can improve their research practices and balance the risk of false-positive and false-negative errors, but also how the movement can capitalize upon insights from research practices within relationship science to make the movement stronger and more inclusive. PsycINFO Database Record (c) 2015 APA, all rights reserved.

  15. Application of matrix-assisted laser desorption ionization time-of-flight mass spectrometry in the screening of vanA-positive Enterococcus faecium.

    PubMed

    Wang, Li-jun; Lu, Xin-xin; Wu, Wei; Sui, Wen-jun; Zhang, Gui

    2014-01-01

    In order to evaluate a rapid matrix-assisted laser desorption ionization-time of flight mass spectrometry (MAIDI-TOF MS) assay in screening vancomycin-resistant Enterococcus faecium, a total of 150 E. faecium clinical strains were studied, including 60 vancomycin-resistant E. faecium (VREF) isolates and 90 vancomycin-susceptible (VSEF) strains. Vancomycin resistance genes were detected by sequencing. E. faecium were identified by MALDI-TOF MS. A genetic algorithm model with ClinProTools software was generated using spectra of 30 VREF isolates and 30 VSEF isolates. Using this model, 90 test isolates were discriminated between VREF and VSEF. The results showed that all sixty VREF isolates carried the vanA gene. The performance of VREF detection by the genetic algorithm model of MALDI-TOF MS compared to the sequencing method was sensitivity = 80%, specificity = 90%, false positive rate =10%, false negative rate =10%, positive predictive value = 80%, negative predictive value= 90%. MALDI-TOF MS can be used as a screening test for discrimination between vanA-positive E. faecium and vanA-negative E. faecium.

  16. Comparison study of the rates of manual peripheral blood smear review from 3 automated hematology analyzers, Unicel DxH 800, ADVIA 2120i, and XE 2100, using international consensus group guidelines.

    PubMed

    Kim, Sue Jung; Kim, Yoonjung; Shin, Saeam; Song, Jaewoo; Choi, Jong Rak

    2012-11-01

    In the clinical laboratory, it is important both to reduce the number of peripheral blood slide reviews to save time and money and to avoid reporting false results. To determine differences in the slide review rates of 3 widely used automated hematologic analyzers, the Unicel DxH 800 (Beckman Coulter Inc, Fullerton, California), ADVIA 2120i (Siemens Diagnostics, Tarrytown, New York), and XE 2100 (Sysmex, Kobe, Japan), using International Consensus Group for Hematology Review guidelines. A total of 1485 samples were tested, and 300 were manually reviewed. Slide review rates, sensitivity, specificity, and false-positive and false-negative rates were estimated using consensus group rules and compared using χ(2) tests, Fisher exact tests, or generalized estimating equations. Unicel DxH 800, ADVIA 2120i, and XE 2100 showed 22.8%, 20.2%, and 28.6% slide review rates; 14.3%, 14.3%, and 9.7% false-negative rates; and 13.7, 11.3%, and 17.3% false-positive rates, respectively. All analyzers showed significantly higher false-negative rates than that of the consensus group (2.9%). False-negative rates were higher than the recommended levels. Among 3 automated hematologic analyzers, XE 2100 showed the highest rate of slide review. Because the present study clearly shows that the slide review rates have distinct characteristics among the studied analyzers, each individual laboratory should consider selecting the most appropriate analyzer according to clinical characteristics. Analyzers with high sensitivity may be advantageous in outpatient settings for screening patients, whereas analyzers with high specificity may be beneficial in inpatient settings for efficient patient care.

  17. Risk of Breast Cancer in Women with False-Positive Results according to Mammographic Features.

    PubMed

    Castells, Xavier; Torá-Rocamora, Isabel; Posso, Margarita; Román, Marta; Vernet-Tomas, Maria; Rodríguez-Arana, Ana; Domingo, Laia; Vidal, Carmen; Baré, Marisa; Ferrer, Joana; Quintana, María Jesús; Sánchez, Mar; Natal, Carmen; Espinàs, Josep A; Saladié, Francina; Sala, María

    2016-08-01

    Purpose To assess the risk of breast cancer in women with false-positive screening results according to radiologic classification of mammographic features. Materials and Methods Review board approval was obtained, with waiver of informed consent. This retrospective cohort study included 521 200 women aged 50-69 years who underwent screening as part of the Spanish Breast Cancer Screening Program between 1994 and 2010 and who were observed until December 2012. Cox proportional hazards regression analysis was used to estimate the age-adjusted hazard ratio (HR) of breast cancer and the 95% confidence interval (CI) in women with false-positive mammograms as compared with women with negative mammograms. Separate models were adjusted for screen-detected and interval cancers and for screen-film and digital mammography. Time without a breast cancer diagnosis was plotted by using Kaplan-Meier curves. Results When compared with women with negative mammograms, the age-adjusted HR of cancer in women with false-positive results was 1.84 (95% CI: 1.73, 1.95; P < .001). The risk was higher in women who had calcifications, whether they were (HR, 2.73; 95% CI: 2.28, 3.28; P < .001) or were not (HR, 2.24; 95% CI: 2.02, 2.48; P < .001) associated with masses. Women in whom mammographic features showed changes in subsequent false-positive results were those who had the highest risk (HR, 9.13; 95% CI: 8.28, 10.07; P < .001). Conclusion Women with false-positive results had an increased risk of breast cancer, particularly women who had calcifications at mammography. Women who had more than one examination with false-positive findings and in whom the mammographic features changed over time had a highly increased risk of breast cancer. Previous mammographic features might yield useful information for further risk-prediction models and personalized follow-up screening protocols. (©) RSNA, 2016 Online supplemental material is available for this article.

  18. Characteristics of enzyme-linked immunosorbent assay for detection of IgG antibodies specific to Сhlamydia trachomatis heat shock protein (HSP-60)

    PubMed

    Galkin, O Yu; Besarab, A B; Lutsenko, T N

    2017-01-01

    The goal of this work was to study sensitivity and specificity of the developed ELISA set for the identification of IgG antibodies against Chlamydia trachomatis HSP-60 (using biotinylated tyramine-based signal amplification system). The study was conducted using a panel of characterized sera, as well as two reference ELISA sets of similar purpose. According to the results of ELISA informative value parameters, the ELISA we have developed showed the highest specificity and sensitivity parameters (no false negative or false positive results were registered). In 4 out of 15 intralaboratory panel serum samples initially identified as negative, anti-HSP-60 IgG-antibodies test result in reference ELISA sets upon dilution changed from negative to positive. The nature of titration curves of false negative sera and commercial monoclonal antibodies А57-В9 against C. trachomatis HSP-60 after incubation for 24 h was indicative of the presence of anti-idiotypic antibodies in these samples. Upon sera dilution, idiotypic-anti-idiotypic complexes dissociated, which caused the change of test result. High informative value of the developed ELISA set for identification of IgG antibodies against C. trachomatis HSP-60 has been proven. Anti-idiotypic antibodies possessing C. trachomatis anti-HSP-60 activity and being one of the causes of false negative results of the relevant ELISA-based tests have been identified in blood sera of individuals infected with chlamydial genitourinary infection agents.

  19. Validation of sentinel lymph node biopsy in breast cancer women N1-N2 with complete axillary response after neoadjuvant chemotherapy. Multicentre study in Tarragona.

    PubMed

    Carrera, D; de la Flor, M; Galera, J; Amillano, K; Gomez, M; Izquierdo, V; Aguilar, E; López, S; Martínez, M; Martínez, S; Serra, J M; Pérez, M; Martin, L

    2016-01-01

    The aim of our study was to evaluate sentinel lymph node biopsy as a diagnostic test for assessing the presence of residual metastatic axillary lymph nodes after neoadjuvant chemotherapy, replacing the need for a lymphadenectomy in negative selective lymph node biopsy patients. A multicentre, diagnostic validation study was conducted in the province of Tarragona, on women with T1-T3, N1-N2 breast cancer, who presented with a complete axillary response after neoadjuvant chemotherapy. Study procedures consisted of performing an selective lymph node biopsy followed by lymphadenectomy. A total of 53 women were included in the study. Surgical detection rate was 90.5% (no sentinel node found in 5 patients). Histopathological analysis of the lymphadenectomy showed complete disease regression of axillary nodes in 35.4% (17/48) of the patients, and residual axillary node involvement in 64.6% (31/48) of them. In lymphadenectomy positive patients, 28 had a positive selective lymph node biopsy (true positive), while 3 had a negative selective lymph node biopsy (false negative). Of the 28 true selective lymph node biopsy positives, the sentinel node was the only positive node in 10 cases. All lymphadenectomy negative cases were selective lymph node biopsy negative. These data yield a sensitivity of 93.5%, a false negative rate of 9.7%, and a global test efficiency of 93.7%. Selective lymph node biopsy after chemotherapy in patients with a complete axillary response provides valid and reliable information regarding axillary status after neoadjuvant treatment, and might prevent lymphadenectomy in cases with negative selective lymph node biopsy. Copyright © 2016 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  20. Emotionally negative pictures enhance gist memory.

    PubMed

    Bookbinder, S H; Brainerd, C J

    2017-02-01

    In prior work on how true and false memory are influenced by emotion, valence and arousal have often been conflated. Thus, it is difficult to say which specific effects are caused by valence and which are caused by arousal. In the present research, we used a picture-memory paradigm that allowed emotional valence to be manipulated with arousal held constant. Negatively valenced pictures elevated both true and false memory, relative to positive and neutral pictures. Conjoint recognition modeling revealed that negative valence (a) reduced erroneous suppression of true memories and (b) increased the familiarity of the semantic content of both true and false memories. Overall, negative valence impaired the verbatim side of episodic memory but enhanced the gist side, and these effects persisted even after a week-long delay. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  1. Histoplasma Urinary Antigen Testing Obviates the Need for Coincident Serum Antigen Testing.

    PubMed

    Libert, Diane; Procop, Gary W; Ansari, Mohammad Q

    2018-03-07

    Serum and urine antigen (SAg, UAg) detection are common tests for Histoplasma capsulatum. UAg detection is more widely used and reportedly has a higher sensitivity. We investigated whether SAg detection contributes meaningfully to the initial evaluation of patients with suspected histoplasmosis. We reviewed 20,285 UAg and 1,426 SAg tests ordered from 1997 to 2016 and analyzed paired UAg and SAg tests completed on the same patient within 1 week. We determined the positivity rate for each test. Of 601 paired specimens, 542 were concurrent negatives and 48 were concurrent positives (98% agreement). Medical records were available for eight of 11 pairs with discrepant results. UAg was falsely positive in six instances, truly positive once, and falsely negative once. These findings support using a single antigen detection test, rather than both UAg and SAg, as an initial screen for suspected histoplasmosis. This aligns with the current practice of most physicians.

  2. Prenatal Genetic Screening Tests

    MedlinePlus

    ... information about the rates of false-positive and false-negative results for each test. What should I consider when deciding whether to have prenatal genetic testing? It is your choice whether to have prenatal testing. Your personal beliefs and values are important factors in the decision ...

  3. The semantics of emotion in false memory.

    PubMed

    Brainerd, C J; Bookbinder, S H

    2018-03-26

    The emotional valence of target information has been a centerpiece of recent false memory research, but in most experiments, it has been confounded with emotional arousal. We sought to clarify the results of such research by identifying a shared mathematical relation between valence and arousal ratings in commonly administered normed materials. That relation was then used to (a) decide whether arousal as well as valence influences false memory when they are confounded and to (b) determine whether semantic properties that are known to affect false memory covary with valence and arousal ratings. In Study 1, we identified a quadratic relation between valence and arousal ratings of words and pictures that has 2 key properties: Arousal increases more rapidly as function of negative valence than positive valence, and hence, a given level of negative valence is more arousing than the same level of positive valence. This quadratic function predicts that if arousal as well as valence affects false memory when they are confounded, false memory data must have certain fine-grained properties. In Study 2, those properties were absent from norming data for the Cornell-Cortland Emotional Word Lists, indicating that valence but not arousal affects false memory in those norms. In Study 3, we tested fuzzy-trace theory's explanation of that pattern: that valence ratings are positively related to semantic properties that are known to increase false memory, but arousal ratings are not. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  4. The Test Validation Summary

    ERIC Educational Resources Information Center

    Frederick, Richard I.; Bowden, Stephen C.

    2009-01-01

    Common rates employed in classificatory testing are the true positive rate (TPR), false positive rate (FPR), positive predictive power (PPP), and negative predictive power (NPP). FPR and TPR are estimated from research samples representing populations to be distinguished by classificatory testing. PPP and NPP are used by clinicians to classify…

  5. Value of the "Test & Treat" Strategy for Uninvestigated Dyspepsia at Low Prevalence Rates of Helicobacter pylori in the Population.

    PubMed

    Agréus, Lars; Talley, Nicholas J; Jones, Michael

    2016-06-01

    In populations with a low prevalence rate of Helicobacter pylori (H. pylori) infection from Western countries, guidelines for the management of uninvestigated dyspepsia generally recommend that the "test and treat" strategy should be avoided in favor of empiric proton-pump inhibitor therapy in younger patients (on average < 50 years of age) without alarm symptoms and signs. The prevalence of H. pylori infection has fallen from about 30% to about 10% in Sweden and other countries. We aimed to explore whether the rationale for test and treat is relevant in contemporary clinical practice. In settings with an infection rate in the adult population of 30% and 10%, we modeled the positive and negative predictive values for indirect (nonendoscopy) tests on current H. pylori infection with a presumed sensitivity and specificity of 95%. We then calculated the difference in false-negative and false-positive test outcome, and eradication prescription rates in the two scenarios. While the positive predictive value for the test decreased from 0.89 to 0.68 when the prevalence of H. pylori fell from 30% to 10%, there were only 1% more false-negative tests and 1% less false-positive tests. The eradication prescription rate would decrease by 18% with a 10% prevalence rate. The recommendation to stop applying "test and treat" at lower prevalence rates of H. pylori should be reconsidered. The test and treat strategy is the preferred approach for most patients who present with dyspepsia. © 2015 John Wiley & Sons Ltd.

  6. Use of Breast Cancer Screening and Its Association with Later Use of Preventive Services among Medicare Beneficiaries.

    PubMed

    Kang, Stella K; Jiang, Miao; Duszak, Richard; Heller, Samantha L; Hughes, Danny R; Moy, Linda

    2018-06-05

    Purpose To retrospectively assess whether there is an association between screening mammography and the use of a variety of preventive services in women who are enrolled in Medicare. Materials and Methods U.S. Medicare claims from 2010 to 2014 Research Identifiable Files were reviewed to retrospectively identify a group of women who underwent screening mammography and a control group without screening mammography in 2012. The screened group was divided into positive versus negative results at screening, and the positive subgroup was divided into false-positive and true-positive findings. Multivariate logistic regression models and inverse probability of treatment weighting were used to examine the relationship between screening status and the probabilities of undergoing Papanicolaou test, bone mass measurement, or influenza vaccination in the following 2 years. Results The cohort consisted of 555 705 patients, of whom 185 625 (33.4%) underwent mammography. After adjusting for patient demographics, comorbidities, geographic covariates, and baseline preventive care, women who underwent index screening mammography (with either positive or negative results) were more likely than unscreened women to later undergo Papanicolaou test (odds ratio [OR], 1.49; 95% confidence interval: 1.40, 1.58), bone mass measurement (OR, 1.70; 95% confidence interval: 1.63, 1.78), and influenza vaccine (OR, 1.45; 95% confidence interval: 1.37, 1.53). In women who had not undergone these preventive measures in the 2 years before screening mammography, use of these three services after false-positive findings at screening was no different than after true-negative findings at screening. Conclusion In beneficiaries of U.S. Medicare, use of screening mammography was associated with higher likelihood of adherence to other preventive guidelines, without a negative association between false-positive results and cervical cancer screening. © RSNA, 2018 Online supplemental material is available for this article.

  7. Sentinel lymph node biopsy is indicated for patients with thick clinically lymph node-negative melanoma.

    PubMed

    Yamamoto, Maki; Fisher, Kate J; Wong, Joyce Y; Koscso, Jonathan M; Konstantinovic, Monique A; Govsyeyev, Nicholas; Messina, Jane L; Sarnaik, Amod A; Cruse, C Wayne; Gonzalez, Ricardo J; Sondak, Vernon K; Zager, Jonathan S

    2015-05-15

    Sentinel lymph node biopsy (SLNB) is indicated for the staging of clinically lymph node-negative melanoma of intermediate thickness, but its use is controversial in patients with thick melanoma. From 2002 to 2012, patients with melanoma measuring ≥4 mm in thickness were evaluated at a single institution. Associations between survival and clinicopathologic characteristics were explored. Of 571 patients with melanomas measuring ≥4 mm in thickness and no distant metastases, the median age was 66 years and 401 patients (70.2%) were male. The median Breslow thickness was 6.2 mm; the predominant subtype was nodular (45.4%). SLNB was performed in 412 patients (72%) whereas 46 patients (8.1%) presented with clinically lymph node-positive disease and 113 patients (20%) did not undergo SLNB. A positive SLN was found in 161 of 412 patients (39.1%). For SLNB performed at the study institution, 14 patients with a negative SLNB developed disease recurrence in the mapped lymph node basin (false-negative rate, 12.3%). The median disease-specific survival (DSS), overall survival (OS), and recurrence-free survival (RFS) for the entire cohort were 62.1 months, 42.5 months, and 21.2 months, respectively. The DSS and OS for patients with a negative SLNB were 82.4 months and 53.4 months, respectively; 41.2 months and 34.7 months, respectively, for patients with positive SLNB; and 26.8 months and 22 months, respectively, for patients with clinically lymph node-positive disease (P<.0001). The median RFS was 32.4 months for patients who were SLNB negative, 14.3 months for patients who were SLNB positive, and 6.8 months for patients with clinically lymph node-positive disease (P<.0001). With an acceptably low false-negative rate, patients with thick melanoma and a negative SLNB appear to have significantly prolonged RFS, DSS, and OS compared with those with a positive SLNB. Therefore, SLNB should be considered as indicated for patients with thick, clinically lymph node-negative melanoma. © 2015 American Cancer Society.

  8. Limited Agreement of Independent RNAi Screens for Virus-Required Host Genes Owes More to False-Negative than False-Positive Factors

    PubMed Central

    Wang, Zhishi; Craven, Mark; Newton, Michael A.; Ahlquist, Paul

    2013-01-01

    Systematic, genome-wide RNA interference (RNAi) analysis is a powerful approach to identify gene functions that support or modulate selected biological processes. An emerging challenge shared with some other genome-wide approaches is that independent RNAi studies often show limited agreement in their lists of implicated genes. To better understand this, we analyzed four genome-wide RNAi studies that identified host genes involved in influenza virus replication. These studies collectively identified and validated the roles of 614 cell genes, but pair-wise overlap among the four gene lists was only 3% to 15% (average 6.7%). However, a number of functional categories were overrepresented in multiple studies. The pair-wise overlap of these enriched-category lists was high, ∼19%, implying more agreement among studies than apparent at the gene level. Probing this further, we found that the gene lists implicated by independent studies were highly connected in interacting networks by independent functional measures such as protein-protein interactions, at rates significantly higher than predicted by chance. We also developed a general, model-based approach to gauge the effects of false-positive and false-negative factors and to estimate, from a limited number of studies, the total number of genes involved in a process. For influenza virus replication, this novel statistical approach estimates the total number of cell genes involved to be ∼2,800. This and multiple other aspects of our experimental and computational results imply that, when following good quality control practices, the low overlap between studies is primarily due to false negatives rather than false-positive gene identifications. These results and methods have implications for and applications to multiple forms of genome-wide analysis. PMID:24068911

  9. Development of a reliable simulation-based test for diagnostic abdominal ultrasound with a pass/fail standard usable for mastery learning.

    PubMed

    Østergaard, Mia L; Nielsen, Kristina R; Albrecht-Beste, Elisabeth; Konge, Lars; Nielsen, Michael B

    2018-01-01

    This study aimed to develop a test with validity evidence for abdominal diagnostic ultrasound with a pass/fail-standard to facilitate mastery learning. The simulator had 150 real-life patient abdominal scans of which 15 cases with 44 findings were selected, representing level 1 from The European Federation of Societies for Ultrasound in Medicine and Biology. Four groups of experience levels were constructed: Novices (medical students), trainees (first-year radiology residents), intermediates (third- to fourth-year radiology residents) and advanced (physicians with ultrasound fellowship). Participants were tested in a standardized setup and scored by two blinded reviewers prior to an item analysis. The item analysis excluded 14 diagnoses. Both internal consistency (Cronbach's alpha 0.96) and inter-rater reliability (0.99) were good and there were statistically significant differences (p < 0.001) between all four groups, except the intermediate and advanced groups (p = 1.0). There was a statistically significant correlation between experience and test scores (Pearson's r = 0.82, p < 0.001). The pass/fail-standard failed all novices (no false positives) and passed all advanced (no false negatives). All intermediate participants and six out of 14 trainees passed. We developed a test for diagnostic abdominal ultrasound with solid validity evidence and a pass/fail-standard without any false-positive or false-negative scores. • Ultrasound training can benefit from competency-based education based on reliable tests. • This simulation-based test can differentiate between competency levels of ultrasound examiners. • This test is suitable for competency-based education, e.g. mastery learning. • We provide a pass/fail standard without false-negative or false-positive scores.

  10. Chemical applicability domain of the Local Lymph Node Assay (LLNA) for skin sensitisation potency. Part 3. Apparent discrepancies between LLNA and GPMT sensitisation potential: False positives or differences in sensitivity?

    PubMed

    Roberts, David W; Schultz, Terry W; Api, Anne Marie

    2016-10-01

    The Local Lymph Node Assay (LLNA) is the gold standard regulatory toxicology test for skin sensitisation along with the guinea pig maximisation test (GPMT). Compared with the GPMT, LLNA uses fewer animals, it is quantitative, and it gives a numerical prediction of potency. However several concerns have been raised with this assay, mainly related to false positives and false negatives. Over the years, many authors, including the developers of the assay, have presented cases where there have been discrepancies between the GMPT and LLNA results. Several theories have been put forward for these discrepancies, the main one being the "over-sensitivity" of the GPMT. This paper analyses the data from a systematic study, published in three papers from 2008 to 2011, covering several classes of chemicals, in particular unsaturated fatty acids, sugar surfactants and ethoxylated alcohols, with many cases of chemicals testing positive in the LLNA being negative in the GPMT. Based on consideration of reaction chemistry and structural alerts, it is concluded that these discrepancies are not LLNA false positives, but can be rationalised in terms of the different protocols of the assays. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. False positives complicate ancient pathogen identifications using high-throughput shotgun sequencing

    PubMed Central

    2014-01-01

    Background Identification of historic pathogens is challenging since false positives and negatives are a serious risk. Environmental non-pathogenic contaminants are ubiquitous. Furthermore, public genetic databases contain limited information regarding these species. High-throughput sequencing may help reliably detect and identify historic pathogens. Results We shotgun-sequenced 8 16th-century Mixtec individuals from the site of Teposcolula Yucundaa (Oaxaca, Mexico) who are reported to have died from the huey cocoliztli (‘Great Pestilence’ in Nahautl), an unknown disease that decimated native Mexican populations during the Spanish colonial period, in order to identify the pathogen. Comparison of these sequences with those deriving from the surrounding soil and from 4 precontact individuals from the site found a wide variety of contaminant organisms that confounded analyses. Without the comparative sequence data from the precontact individuals and soil, false positives for Yersinia pestis and rickettsiosis could have been reported. Conclusions False positives and negatives remain problematic in ancient DNA analyses despite the application of high-throughput sequencing. Our results suggest that several studies claiming the discovery of ancient pathogens may need further verification. Additionally, true single molecule sequencing’s short read lengths, inability to sequence through DNA lesions, and limited ancient-DNA-specific technical development hinder its application to palaeopathology. PMID:24568097

  12. Occupational exposure assessment of magnetic fields generated by induction heating equipment-the role of spatial averaging.

    PubMed

    Kos, Bor; Valič, Blaž; Kotnik, Tadej; Gajšek, Peter

    2012-10-07

    Induction heating equipment is a source of strong and nonhomogeneous magnetic fields, which can exceed occupational reference levels. We investigated a case of an induction tempering tunnel furnace. Measurements of the emitted magnetic flux density (B) were performed during its operation and used to validate a numerical model of the furnace. This model was used to compute the values of B and the induced in situ electric field (E) for 15 different body positions relative to the source. For each body position, the computed B values were used to determine their maximum and average values, using six spatial averaging schemes (9-285 averaging points) and two averaging algorithms (arithmetic mean and quadratic mean). Maximum and average B values were compared to the ICNIRP reference level, and E values to the ICNIRP basic restriction. Our results show that in nonhomogeneous fields, the maximum B is an overly conservative predictor of overexposure, as it yields many false positives. The average B yielded fewer false positives, but as the number of averaging points increased, false negatives emerged. The most reliable averaging schemes were obtained for averaging over the torso with quadratic averaging, with no false negatives even for the maximum number of averaging points investigated.

  13. Frequency of false-negative reactions to the fragrance mix.

    PubMed

    de Groot, A C; van der Kley, A M; Bruynzeel, D P; Meinardi, M M; Smeenk, G; van Joost, T; Pavel, S

    1993-03-01

    To estimate the frequency of false-negative reactions to the fragrance mix, the 8 constituents of the mix in concentrations of 5% (2% for cinnamic aldehyde) were added to the European standard series for routine testing. Patients with positive reactions to individual ingredients in the absence of a reaction to the mix were retested with serial dilutions. In a 4-month period, 677 patients were tested. 61 (9%) reacted to the mix and to 1 or more of the ingredients. 4 patients (0.6% of all patients tested and 6.2% of the patients allergic to fragrances) had false-negative reactions to the mix. They were allergic to cinnamic alcohol, geraniol, isoeugenol and oak moss (1 reaction each), in the absence of a reaction to the fragrance mix. It is concluded that the currently used concentration of the mix (8 x 1%) not infrequently results in false-negative reactions, and that further research should be done to overcome this problem.

  14. Preschool children's vision screening in New Zealand: a retrospective evaluation of referral accuracy

    PubMed Central

    Langeslag-Smith, Miriam A; Vandal, Alain C; Briane, Vincent; Thompson, Benjamin; Anstice, Nicola S

    2015-01-01

    Objectives To assess the accuracy of preschool vision screening in a large, ethnically diverse, urban population in South Auckland, New Zealand. Design Retrospective longitudinal study. Methods B4 School Check vision screening records (n=5572) were compared with hospital eye department data for children referred from screening due to impaired acuity in one or both eyes who attended a referral appointment (n=556). False positive screens were identified by comparing screening data from the eyes that failed screening with hospital data. Estimation of false negative screening rates relied on data from eyes that passed screening. Data were analysed using logistic regression modelling accounting for the high correlation between results for the two eyes of each child. Primary outcome measure Positive predictive value of the preschool vision screening programme. Results Screening produced high numbers of false positive referrals, resulting in poor positive predictive value (PPV=31%, 95% CI 26% to 38%). High estimated negative predictive value (NPV=92%, 95% CI 88% to 95%) suggested most children with a vision disorder were identified at screening. Relaxing the referral criteria for acuity from worse than 6/9 to worse than 6/12 improved PPV without adversely affecting NPV. Conclusions The B4 School Check generated numerous false positive referrals and consequently had a low PPV. There is scope for reducing costs by altering the visual acuity criterion for referral. PMID:26614622

  15. An analysis of whether surgeon-performed neck ultrasound can be used as the main localizing study in primary hyperparathyroidism.

    PubMed

    Aliyev, Shamil; Agcaoglu, Orhan; Aksoy, Erol; Birsen, Onur; Milas, Mira; Mitchell, Jamie; Siperstein, Allan; Berber, Eren

    2014-11-01

    Tc-99 sestamibi (MIBI) scan is the imaging study most frequently used in primary hyperparathyroidism (PHP). Transcutaneous cervical ultrasonography (US) is the other modality used for preoperative localization. The aim of this study was to determine whether surgeon-performed neck US can be used as the primary localizing study in PHP. This was a prospective study of 1,000 consecutive patients with first-time, sporadic PHP who underwent parathyroidectomy at a tertiary academic center. All patients had surgeon-performed neck US and MIBI before bilateral neck exploration. The findings at exploration were 72% single adenoma, 15% double adenoma, and 13% hyperplasia. When US suggested single-gland disease (n = 842), MIBI was concordant in 82.5%, discordant and false in 8%, negative in 7%, and discordant but correct in 2.5%. When US suggested multigland disease (n = 68), MIBI was concordant in 47%, discordant and false in 41%, and negative in 12%. When US was negative (n = 90), MIBI was positive and correct in 43%, negative in 31%, and positive but false in 26%. Surgeon-performed neck US identified unrecognized thyroid nodules in 326 patients (33%), which led to fine-needle aspiration biopsy in 161 (49%) patients and thyroid surgery in 103 (32%) patients, with a final diagnosis of thyroid cancer in 24 (7%) patients. Our results show that MIBI provides additional useful information in only a minority of patients with a positive US in PHP. Nevertheless, MIBI benefits about half of patients with a negative US. Because one-third of this patient population has unrecognized thyroid nodules as well, we propose that the most cost-effective algorithm would be to do US first and reserve MIBI for US-negative cases. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. The Illusion of the Positive: The impact of natural and induced mood on older adults’ false recall

    PubMed Central

    Emery, Lisa; Hess, Thomas M.; Elliot, Tonya

    2012-01-01

    Recent research suggests that affective and motivational processes can influence age differences in memory. In the current study, we examine the impact of both natural and induced mood state on age differences in false recall. Older and younger adults performed a version of the Deese-Roediger-McDermott (DRM; Roediger & McDermott, 1995) false memory paradigm in either their natural mood state or after a positive or negative mood induction. Results indicated that, after accounting for age differences in basic cognitive function, age-related differences in positive mood during the testing session were related to increased false recall in older adults. Inducing older adults into a positive mood also exacerbated age differences in false memory. In contrast, veridical recall did not appear to be systematically influenced by mood. Together, these results suggest that positive mood states can impact older adults’ information processing and potentially increase underlying cognitive age differences. PMID:22292431

  17. The illusion of the positive: the impact of natural and induced mood on older adults' false recall.

    PubMed

    Emery, Lisa; Hess, Thomas M; Elliot, Tonya

    2012-11-01

    Recent research suggests that affective and motivational processes can influence age differences in memory. In the current study, we examine the impact of both natural and induced mood state on age differences in false recall. Older and younger adults performed a version of the Deese-Roediger-McDermott (DRM; Roediger & McDermott, 1995 , Journal of Experimental Psychology: Learning, Memory, and Cognition, 21, 803) false memory paradigm in either their natural mood state or after a positive or negative mood induction. Results indicated that, after accounting for age differences in basic cognitive function, age-related differences in positive mood during the testing session were related to increased false recall in older adults. Inducing older adults into a positive mood also exacerbated age differences in false memory. In contrast, veridical recall did not appear to be systematically influenced by mood. Together, these results suggest that positive mood states can impact older adults' information processing and potentially increase underlying cognitive age differences.

  18. Robust Detection of Rare Species Using Environmental DNA: The Importance of Primer Specificity

    PubMed Central

    Wilcox, Taylor M.; McKelvey, Kevin S.; Young, Michael K.; Jane, Stephen F.; Lowe, Winsor H.; Whiteley, Andrew R.; Schwartz, Michael K.

    2013-01-01

    Environmental DNA (eDNA) is being rapidly adopted as a tool to detect rare animals. Quantitative PCR (qPCR) using probe-based chemistries may represent a particularly powerful tool because of the method’s sensitivity, specificity, and potential to quantify target DNA. However, there has been little work understanding the performance of these assays in the presence of closely related, sympatric taxa. If related species cause any cross-amplification or interference, false positives and negatives may be generated. These errors can be disastrous if false positives lead to overestimate the abundance of an endangered species or if false negatives prevent detection of an invasive species. In this study we test factors that influence the specificity and sensitivity of TaqMan MGB assays using co-occurring, closely related brook trout (Salvelinus fontinalis) and bull trout (S. confluentus) as a case study. We found qPCR to be substantially more sensitive than traditional PCR, with a high probability of detection at concentrations as low as 0.5 target copies/µl. We also found that number and placement of base pair mismatches between the Taqman MGB assay and non-target templates was important to target specificity, and that specificity was most influenced by base pair mismatches in the primers, rather than in the probe. We found that insufficient specificity can result in both false positive and false negative results, particularly in the presence of abundant related species. Our results highlight the utility of qPCR as a highly sensitive eDNA tool, and underscore the importance of careful assay design. PMID:23555689

  19. Robust detection of rare species using environmental DNA: the importance of primer specificity.

    PubMed

    Wilcox, Taylor M; McKelvey, Kevin S; Young, Michael K; Jane, Stephen F; Lowe, Winsor H; Whiteley, Andrew R; Schwartz, Michael K

    2013-01-01

    Environmental DNA (eDNA) is being rapidly adopted as a tool to detect rare animals. Quantitative PCR (qPCR) using probe-based chemistries may represent a particularly powerful tool because of the method's sensitivity, specificity, and potential to quantify target DNA. However, there has been little work understanding the performance of these assays in the presence of closely related, sympatric taxa. If related species cause any cross-amplification or interference, false positives and negatives may be generated. These errors can be disastrous if false positives lead to overestimate the abundance of an endangered species or if false negatives prevent detection of an invasive species. In this study we test factors that influence the specificity and sensitivity of TaqMan MGB assays using co-occurring, closely related brook trout (Salvelinus fontinalis) and bull trout (S. confluentus) as a case study. We found qPCR to be substantially more sensitive than traditional PCR, with a high probability of detection at concentrations as low as 0.5 target copies/µl. We also found that number and placement of base pair mismatches between the Taqman MGB assay and non-target templates was important to target specificity, and that specificity was most influenced by base pair mismatches in the primers, rather than in the probe. We found that insufficient specificity can result in both false positive and false negative results, particularly in the presence of abundant related species. Our results highlight the utility of qPCR as a highly sensitive eDNA tool, and underscore the importance of careful assay design.

  20. A cluster of culture positive gonococcal infections but with false negative cppB gene based PCR.

    PubMed

    Lum, G; Freeman, K; Nguyen, N L; Limnios, E A; Tabrizi, S N; Carter, I; Chambers, I W; Whiley, D M; Sloots, T P; Garland, S M; Tapsall, J W

    2005-10-01

    To describe the prevalence and characteristics of isolates of Neisseria gonorrhoeae grown from urine samples that produced negative results with nucleic acid amplification assays (NAA) targeting the cppB gene. An initial cluster of culture positive, but cppB gene based NAA negative, gonococcal infections was recognised. Urine samples and suspensions of gonococci isolated over 9 months in the Northern Territory of Australia were examined using cppB gene based and other non-cppB gene based NAA. The gonococcal isolates were phenotyped by determining the auxotype/serovar (A/S) class and genotyped by pulsed field gel electrophoresis (PFGE). 14 (9.8%) of 143 gonococci isolated were of A/S class Pro(-/)Brpyut, indistinguishable on PFGE and negative in cppB gene based, but not other, NAA. This cluster represents a temporal and geographic expansion of a gonococcal subtype lacking the cppB gene with consequent loss of sensitivity of NAA dependent on amplification of this target. Gonococci lacking the cppB gene have in the past been more commonly associated with the PAU-/PCU- auxotype, a gonococcal subtype hitherto infrequently encountered in Australia. NAA based on the cppB gene as a target may produce false positive as well as false negative NAA. This suggests that unless there is continuing comparison with culture to show their utility, cppB gene based NAA should be regarded as suboptimal for use either as a diagnostic or supplemental assay for diagnosis of gonorrhoea, and NAA with alternative amplification targets should be substituted.

  1. Predicting the severity of motor neuron disease progression using electronic health record data with a cloud computing Big Data approach.

    PubMed

    Ko, Kyung Dae; El-Ghazawi, Tarek; Kim, Dongkyu; Morizono, Hiroki

    2014-05-01

    Motor neuron diseases (MNDs) are a class of progressive neurological diseases that damage the motor neurons. An accurate diagnosis is important for the treatment of patients with MNDs because there is no standard cure for the MNDs. However, the rates of false positive and false negative diagnoses are still very high in this class of diseases. In the case of Amyotrophic Lateral Sclerosis (ALS), current estimates indicate 10% of diagnoses are false-positives, while 44% appear to be false negatives. In this study, we developed a new methodology to profile specific medical information from patient medical records for predicting the progression of motor neuron diseases. We implemented a system using Hbase and the Random forest classifier of Apache Mahout to profile medical records provided by the Pooled Resource Open-Access ALS Clinical Trials Database (PRO-ACT) site, and we achieved 66% accuracy in the prediction of ALS progress.

  2. Network Compression as a Quality Measure for Protein Interaction Networks

    PubMed Central

    Royer, Loic; Reimann, Matthias; Stewart, A. Francis; Schroeder, Michael

    2012-01-01

    With the advent of large-scale protein interaction studies, there is much debate about data quality. Can different noise levels in the measurements be assessed by analyzing network structure? Because proteomic regulation is inherently co-operative, modular and redundant, it is inherently compressible when represented as a network. Here we propose that network compression can be used to compare false positive and false negative noise levels in protein interaction networks. We validate this hypothesis by first confirming the detrimental effect of false positives and false negatives. Second, we show that gold standard networks are more compressible. Third, we show that compressibility correlates with co-expression, co-localization, and shared function. Fourth, we also observe correlation with better protein tagging methods, physiological expression in contrast to over-expression of tagged proteins, and smart pooling approaches for yeast two-hybrid screens. Overall, this new measure is a proxy for both sensitivity and specificity and gives complementary information to standard measures such as average degree and clustering coefficients. PMID:22719828

  3. Challenges associated with post-deployment screening for mild traumatic brain injury in military personnel.

    PubMed

    Iverson, Grant L; Langlois, Jean A; McCrea, Michael A; Kelly, James P

    2009-11-01

    There is ongoing debate regarding the epidemiology of mild traumatic brain injury (MTBI) in military personnel. Accurate and timely estimates of the incidence of brain injury and the prevalence of long-term problems associated with brain injuries among active duty service members and veterans are essential for (a) operational planning, and (b) to allocate sufficient resources for rehabilitation and ongoing services and supports. The purpose of this article is to discuss challenges associated with post-deployment screening for MTBI. Multiple screening methods have been used in military, Veterans Affairs, and independent studies, which complicate cross-study comparisons of the resulting epidemiological data. We believe that post-deployment screening is important and necessary--but no screening methodology will be flawless, and false positives and false negatives are inevitable. Additional research is necessary to refine the sequential screening methodology, with the goal of minimizing false negatives during initial post-deployment screening and minimizing false positives during follow-up evaluations.

  4. Microscopic diagnosis of vulvovaginal candidiasis in stained vaginal smears by Dutch general practitioners.

    PubMed

    Engberts, Marian K; Goedbloed, Annelize F; van Haaften, Maarten; van Haaften, Mathilde; Boon, Mathilde E; Boon, Maarten E; Heintz, Peter M

    2007-01-01

    To determine the accuracy of the microscopic diagnosis of vulvovaginal candidiasis (presence of [pseudo] hyphae and blastospores) in stained vaginal smears in clinical practice. General practitioners trained in diagnosing vulvovaginal candidiasis performed microscopy of 324 stained vaginal smears. These smears were sent to the pathologist for confirmation of the microscopic diagnosis of the clinician; cytologic diagnosis by the pathologist was considered the gold standard. In 104 of the 342 cases Candida was established by the pathologist. The clinicians made 24 false positive and 50 false negative diagnoses of Candida. Sensitivity and specificity of the microscopic diagnoses of the clinicians were 52% and 89%, respectively. The most frequent reason for a false positive diagnosis was presence of hairs, whereas the most frequent reason for a false negative diagnosis was understaining of the smear. This study shows that even in stained smears it is difficult for clinicians to recognize blastospores and (pseudo)hyphae. Efforts are clearly needed to improve the quality of the clinical diagnosis of vulvovaginal candidiasis.

  5. To err is human, to correct is public health: a systematic review examining poor quality testing and misdiagnosis of HIV status

    PubMed Central

    Johnson, Cheryl C.; Fonner, Virginia; Sands, Anita; Ford, Nathan; Obermeyer, Carla Mahklouf; Tsui, Sharon; Wong, Vincent; Baggaley, Rachel

    2017-01-01

    Abstract Introduction: In accordance with global testing and treatment targets, many countries are seeking ways to reach the “90-90-90” goals, starting with diagnosing 90% of all people with HIV. Quality HIV testing services are needed to enable people with HIV to be diagnosed and linked to treatment as early as possible. It is essential that opportunities to reach people with undiagnosed HIV are not missed, diagnoses are correct and HIV-negative individuals are not inadvertently initiated on life-long treatment. We conducted this systematic review to assess the magnitude of misdiagnosis and to describe poor HIV testing practices using rapid diagnostic tests. Methods: We systematically searched peer-reviewed articles, abstracts and grey literature published from 1 January 1990 to 19 April 2017. Studies were included if they used at least two rapid diagnostic tests and reported on HIV misdiagnosis, factors related to potential misdiagnosis or described quality issues and errors related to HIV testing. Results: Sixty-four studies were included in this review. A small proportion of false positive (median 3.1%, interquartile range (IQR): 0.4-5.2%) and false negative (median: 0.4%, IQR: 0-3.9%) diagnoses were identified. Suboptimal testing strategies were the most common factor in studies reporting misdiagnoses, particularly false positive diagnoses due to using a “tiebreaker” test to resolve discrepant test results. A substantial proportion of false negative diagnoses were related to retesting among people on antiretroviral therapy. Conclusions: HIV testing errors and poor practices, particularly those resulting in false positive or false negative diagnoses, do occur but are preventable. Efforts to accelerate HIV diagnosis and linkage to treatment should be complemented by efforts to improve the quality of HIV testing services and strengthen the quality management systems, particularly the use of validated testing algorithms and strategies, retesting people diagnosed with HIV before initiating treatment and providing clear messages to people with HIV on treatment on the risk of a “false negative” test result. PMID:28872271

  6. Skin irritation, false positives and the local lymph node assay: a guideline issue?

    PubMed

    Basketter, David A; Kimber, Ian

    2011-10-01

    Since the formal validation and regulatory acceptance of the local lymph node assay (LLNA) there have been commentaries suggesting that the irritant properties of substances can give rise to false positives. As toxicology aspires to progress rapidly towards the age of in vitro alternatives, it is of increasing importance that issues relating to assay selectivity and performance are understood fully, and that true false positive responses are distinguished clearly from those that are simply unpalatable. In the present review, we have focused on whether skin irritation per se is actually a direct cause of true false positive results in the LLNA. The body of published work has been examined critically and considered in relation to our current understanding of the mechanisms of skin irritation and skin sensitisation. From these analyses it is very clear that, of itself, skin irritation is not a cause of false positive results. The corollary is, therefore, that limiting test concentrations in the LLNA for the purpose of avoiding skin irritation may lead, unintentionally, to false negatives. Where a substance is a true false positive in the LLNA, the classic example being sodium lauryl sulphate, explanations for that positivity will have to reach beyond the seductive, but incorrect, recourse to its skin irritation potential. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. True and false recall and dissociation among maltreated children: the role of self-schema.

    PubMed

    Valentino, Kristin; Cicchetti, Dante; Rogosch, Fred A; Toth, Sheree L

    2008-01-01

    The current investigation addresses the manner through which trauma affects basic memory and self-system processes. True and false recall for self-referent stimuli were assessed in conjunction with dissociative symptomatology among abused (N=76), neglected (N=92), and nonmaltreated (N=116) school-aged children. Abused, neglected, and nonmaltreated children did not differ in the level of processing self-schema effect or in the occurrence and frequency of false recall. Rather, differences in the affective valence of false recall emerged as a function of maltreatment subtype and age. Regarding dissociation, the abused children displayed higher levels of dissociative symptomatology than did the nonmaltreated children. Although abused, neglected, and nonmaltreated children did not exhibit differences in the valence of their self-schemas, positive and negative self-schemas were related to self-integration differently among the subgroups of maltreatment. Negative self-schemas were associated with increased dissociation among the abused children, whereas positive self-schemas were related to increased dissociation for the neglected children. Thus, positive self-schemas displayed by the younger neglected children were related to higher dissociation, suggestive of defensive self-processing. Implications for clinical intervention are underscored.

  8. One or two serological assay testing strategy for diagnosis of HBV and HCV infection? The use of predictive modelling.

    PubMed

    Parry, John V; Easterbrook, Philippa; Sands, Anita R

    2017-11-01

    Initial serological testing for chronic hepatitis B virus (HBV) and hepatitis C virus (HCV) infection is conducted using either rapid diagnostic tests (RDT) or laboratory-based enzyme immunoassays (EIA)s for detection of hepatitis B surface antigen (HBsAg) or antibodies to HCV (anti-HCV), typically on serum or plasma specimens and, for certain RDTs, capillary whole blood. WHO recommends the use of standardized testing strategies - defined as a sequence of one or more assays to maximize testing accuracy while simplifying the testing process and ideally minimizing cost. Our objective was to examine the diagnostic outcomes of a one- versus two-assay serological testing strategy. These data were used to inform recommendations in the 2017 WHO Guidelines on hepatitis B and C testing. Few published studies have compared diagnostic outcomes for one-assay versus two-assay serological testing strategies for HBsAg and anti-HCV. Therefore, the principles of Bayesian statistics were used to conduct a modelling exercise to examine the outcomes of a one-assay versus two-assay testing strategy when applied to a hypothetical population of 10,000 individuals. The resulting model examined the diagnostic outcomes (true and false positive diagnoses; true and false negative diagnoses; positive and negative predictive values as a function of prevalence; and total tests required) for both one-assay and two-assay testing strategies. The performance characteristics assumed for assays used within the testing strategies were informed by WHO prequalification assessment findings and systematic reviews for diagnostic accuracy studies. Each of the presumptive testing strategies (one-assay or two-assay) was modelled at varying prevalences of HBsAg (10%, 2% and 0.4%) and of anti-HCV (40%, 10%, 2% and 0.4%), aimed at representing the range of testing populations typically encountered in WHO Member States. When the two-assay testing strategy was considered, the model assumed the independence of the two assays. Modeling demonstrated that applying a single assay (HBsAg or anti-HCV), even with high specificity (99%), may result in considerable numbers of false positive diagnoses and low positive predictive values (PPV), particularly in lower prevalence settings. Even at very low prevalences shifting to a two-assay testing strategy would result in a PPV approaching 1.0. When test sensitivity is high (>99%) false negative reactions are rare at all but the highest prevalences; but a two-test strategy might yield more false negative diagnoses. The order in which the tests are used has no impact on the overall accuracy of a two-assay strategy though it may impact the total number of tests needed to complete the diagnostic strategy, incurring added cost and complexity. HBsAg assays may have a low sensitivity (<90%), and result in large numbers of false negative diagnoses, particularly in high prevalence settings, which would be exacerbated in the two-assay testing strategy. In contrast, most anti-HCV assays have high sensitivity and lead to fewer false negative results, both in the one-assay and two-assay testing strategies. At prevalences ≤2% the number of tests needed using a second assay was nearly always small, at <300 per 10,000 individuals tested, making sustainability of a second assay uncertain in such a setting. A key public health objective of an effective testing strategy is to identify all individuals who would benefit from treatment. Therefore, a strategy that prioritizes a high NPV (minimal false negatives) may be acceptable even if the PPV is suboptimal (some false positives) as the implementation of such a public health programme must also take account of other factors such as costs, feasibility, impact on testing uptake and linkage to care, and consequences of a false-positive test. This rationale informed the development of the WHO Viral Hepatitis Testing Guidelines, with a conditional recommendation for a one-assay serological testing strategy in most testing settings and populations (≥0.4% prevalence in population tested). A one-test strategy results in few failures to diagnose infection and, although it is associated under most assumptions with a sub-optimal PPV, benefits include greater simplicity, easier implementation, lower costs and better feasibility, uptake and linkage to care. Furthermore, prior to antiviral therapy all those diagnosed either HBsAg or anti-HCV positive will require confirmation of viræmia, preventing unnecessary treatment of those who may be false positive on serology. For HBsAg, in low-prevalence settings (≤0.4%), a second recommendation was made to consider a two-assay testing strategy, using a confirmatory neutralization step or a second different HBsAg assay.

  9. Comparison of scanty AFB smears against culture in an area with high HIV prevalence.

    PubMed

    Lawson, L; Yassin, M A; Ramsay, A; Emenyonu, N E; Squire, S B; Cuevas, L E

    2005-08-01

    To verify among tuberculosis (TB) suspects attending hospitals in Abuja, Nigeria, if sputum smears graded as scanty are false-positive, sputum smears from 1068 patients were graded with the International Union Against Tuberculosis and Lung Disease classification. One specimen was cultured. Eight hundred and twenty-four (26%) smears were positive, 137 (4%) scanty and 2243 negative. Of 1068 cultures, 680 (64%) were positive. One hundred and thirty (95%) scanty and 809 (98%) positive smears were culture-positive. Twelve of 18 patients with a single scanty smear and 51 of 52 with > or = 2 scanty smears were culture-positive. Fewer than < 5% scanty results, < 1% of the patients treated for TB, are false-positive.

  10. Evaluation of microtiter-plate enzyme-linked immunosorbent assay for the analysis of triazine and chloroacetanilide herbicides in rainfall

    USGS Publications Warehouse

    Pomes, M.L.; Thurman, E.M.; Aga, D.S.; Goolsby, D.A.

    1998-01-01

    Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false- positive rate of 11.8% and the chloroacetanilide ELISA yielded a false- negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false-positive rate of 11.8% and the chloroacetanilide ELISA yielded a false-negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.

  11. Children's False Memory and True Disclosure in the Face of Repeated Questions

    ERIC Educational Resources Information Center

    Schaaf, Jennifer M.; Alexander, Kristen Weede; Goodman, Gail S.

    2008-01-01

    The current study was designed to investigate children's memory and suggestibility for events differing in valence (positive or negative) and veracity (true or false). A total of 82 3- and 5-year-olds were asked repeated questions about true and false events, either in a grouped order (i.e., all questions about a certain event asked consecutively)…

  12. HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites

    PubMed Central

    Kosack, Cara S.; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng’ang’a, Anne; Andre, Bita; Zahinda, Jean-Paul BN; Fransen, Katrien; Page, Anne-Laure

    2017-01-01

    Abstract Introduction: We evaluated the diagnostic accuracy of HIV testing algorithms at six programmes in five sub-Saharan African countries. Methods: In this prospective multisite diagnostic evaluation study (Conakry, Guinea; Kitgum, Uganda; Arua, Uganda; Homa Bay, Kenya; Doula, Cameroun and Baraka, Democratic Republic of Congo), samples from clients (greater than equal to five years of age) testing for HIV were collected and compared to a state-of-the-art algorithm from the AIDS reference laboratory at the Institute of Tropical Medicine, Belgium. The reference algorithm consisted of an enzyme-linked immuno-sorbent assay, a line-immunoassay, a single antigen-enzyme immunoassay and a DNA polymerase chain reaction test. Results: Between August 2011 and January 2015, over 14,000 clients were tested for HIV at 6 HIV counselling and testing sites. Of those, 2786 (median age: 30; 38.1% males) were included in the study. Sensitivity of the testing algorithms ranged from 89.5% in Arua to 100% in Douala and Conakry, while specificity ranged from 98.3% in Doula to 100% in Conakry. Overall, 24 (0.9%) clients, and as many as 8 per site (1.7%), were misdiagnosed, with 16 false-positive and 8 false-negative results. Six false-negative specimens were retested with the on-site algorithm on the same sample and were found to be positive. Conversely, 13 false-positive specimens were retested: 8 remained false-positive with the on-site algorithm. Conclusions: The performance of algorithms at several sites failed to meet expectations and thresholds set by the World Health Organization, with unacceptably high rates of false results. Alongside the careful selection of rapid diagnostic tests and the validation of algorithms, strictly observing correct procedures can reduce the risk of false results. In the meantime, to identify false-positive diagnoses at initial testing, patients should be retested upon initiating antiretroviral therapy. PMID:28691437

  13. HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites.

    PubMed

    Kosack, Cara S; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng'ang'a, Anne; Andre, Bita; Zahinda, Jean-Paul Bn; Fransen, Katrien; Page, Anne-Laure

    2017-07-03

    We evaluated the diagnostic accuracy of HIV testing algorithms at six programmes in five sub-Saharan African countries. In this prospective multisite diagnostic evaluation study (Conakry, Guinea; Kitgum, Uganda; Arua, Uganda; Homa Bay, Kenya; Doula, Cameroun and Baraka, Democratic Republic of Congo), samples from clients (greater than equal to five years of age) testing for HIV were collected and compared to a state-of-the-art algorithm from the AIDS reference laboratory at the Institute of Tropical Medicine, Belgium. The reference algorithm consisted of an enzyme-linked immuno-sorbent assay, a line-immunoassay, a single antigen-enzyme immunoassay and a DNA polymerase chain reaction test. Between August 2011 and January 2015, over 14,000 clients were tested for HIV at 6 HIV counselling and testing sites. Of those, 2786 (median age: 30; 38.1% males) were included in the study. Sensitivity of the testing algorithms ranged from 89.5% in Arua to 100% in Douala and Conakry, while specificity ranged from 98.3% in Doula to 100% in Conakry. Overall, 24 (0.9%) clients, and as many as 8 per site (1.7%), were misdiagnosed, with 16 false-positive and 8 false-negative results. Six false-negative specimens were retested with the on-site algorithm on the same sample and were found to be positive. Conversely, 13 false-positive specimens were retested: 8 remained false-positive with the on-site algorithm. The performance of algorithms at several sites failed to meet expectations and thresholds set by the World Health Organization, with unacceptably high rates of false results. Alongside the careful selection of rapid diagnostic tests and the validation of algorithms, strictly observing correct procedures can reduce the risk of false results. In the meantime, to identify false-positive diagnoses at initial testing, patients should be retested upon initiating antiretroviral therapy.

  14. Limitations of Rapid Diagnostic Testing in Patients with Suspected Malaria: A Diagnostic Accuracy Evaluation from Swaziland, a Low-Endemicity Country Aiming for Malaria Elimination

    PubMed Central

    Ranadive, Nikhil; Kunene, Simon; Darteh, Sarah; Ntshalintshali, Nyasatu; Nhlabathi, Nomcebo; Dlamini, Nomcebo; Chitundu, Stanley; Saini, Manik; Murphy, Maxwell; Soble, Adam; Schwartz, Alanna; Greenhouse, Bryan

    2017-01-01

    Abstract Background. The performance of Plasmodium falciparum–specific histidine-rich protein 2–based rapid diagnostic tests (RDTs) to evaluate suspected malaria in low-endemicity settings has not been well characterized. Methods. Using dried blood spot samples from patients with suspected malaria at 37 health facilities from 2012 to 2014 in the low-endemicity country of Swaziland, we investigated the diagnostic accuracy of histidine-rich protein 2–based RDTs using qualitative polymerase chain reaction (PCR) (nested PCR targeting the cytochrome b gene) and quantitative PCR as reference standards. To explore reasons for false-negative and/or false-positive results, we used pfhrp2/3-specific PCR and logistic regression analyses of potentially associated epidemiological factors. Results. From 1353 patients, 93.0% of RDT-positive (n = 185) and 31.2% of RDT-negative samples (n = 340) were available and selected for testing. Compared with nested PCR, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of RDTs were 51.7%, 94.1%, 67.3%, and 89.1%, respectively. After exclusion of samples with parasite densities <100/μL, which accounted for 75.7% of false-negative results and 33.3% of PCR-detectable infections, the sensitivity, specificity, PPV, and NPV were 78.8%, 93.7%, 62.3%, and 97.1%. Deletions of pfhrp2 were not detected. False-positivity was more likely during the second year and was not associated with demographics, recent malaria, health facility testing characteristics, or potential DNA degradation. Conclusions. In the low-transmission setting of Swaziland, we demonstrated low sensitivity of RDT for malaria diagnosis, owing to an unexpectedly high proportion of low-density infection among symptomatic subjects. The PPV was also low, requiring further investigation. A more accurate point-of-care diagnostic may be needed to support malaria elimination efforts. PMID:28369268

  15. Limitations of Rapid Diagnostic Testing in Patients with Suspected Malaria: A Diagnostic Accuracy Evaluation from Swaziland, a Low-Endemicity Country Aiming for Malaria Elimination.

    PubMed

    Ranadive, Nikhil; Kunene, Simon; Darteh, Sarah; Ntshalintshali, Nyasatu; Nhlabathi, Nomcebo; Dlamini, Nomcebo; Chitundu, Stanley; Saini, Manik; Murphy, Maxwell; Soble, Adam; Schwartz, Alanna; Greenhouse, Bryan; Hsiang, Michelle S

    2017-05-01

    The performance of Plasmodium falciparum-specific histidine-rich protein 2-based rapid diagnostic tests (RDTs) to evaluate suspected malaria in low-endemicity settings has not been well characterized. Using dried blood spot samples from patients with suspected malaria at 37 health facilities from 2012 to 2014 in the low-endemicity country of Swaziland, we investigated the diagnostic accuracy of histidine-rich protein 2-based RDTs using qualitative polymerase chain reaction (PCR) (nested PCR targeting the cytochrome b gene) and quantitative PCR as reference standards. To explore reasons for false-negative and/or false-positive results, we used pfhrp2/3-specific PCR and logistic regression analyses of potentially associated epidemiological factors. From 1353 patients, 93.0% of RDT-positive (n = 185) and 31.2% of RDT-negative samples (n = 340) were available and selected for testing. Compared with nested PCR, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of RDTs were 51.7%, 94.1%, 67.3%, and 89.1%, respectively. After exclusion of samples with parasite densities <100/μL, which accounted for 75.7% of false-negative results and 33.3% of PCR-detectable infections, the sensitivity, specificity, PPV, and NPV were 78.8%, 93.7%, 62.3%, and 97.1%. Deletions of pfhrp2 were not detected. False-positivity was more likely during the second year and was not associated with demographics, recent malaria, health facility testing characteristics, or potential DNA degradation. In the low-transmission setting of Swaziland, we demonstrated low sensitivity of RDT for malaria diagnosis, owing to an unexpectedly high proportion of low-density infection among symptomatic subjects. The PPV was also low, requiring further investigation. A more accurate point-of-care diagnostic may be needed to support malaria elimination efforts. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  16. [Evaluation of quality of HIV diagnostic procedures in Poland].

    PubMed

    Parczewski, Miłosz; Madaliński, Kazimierz; Leszczyszyn-Pynka, Magdalena; Boroń-Kaczmarska, Anna

    2010-01-01

    The aim of this work was quality assessment of HIV diagnostic procedures in Poland, including human and technical resources as well as laboratory practice. Sixty questionnaires were distributed among diagnostic centers to obtain qualitative data. Basing on the survey data serological control using coded panels of HIV-1/2 samples was performed. Thirty-one filled questionnaires were received (50.8%). Surveyed laboratories perform from 350 to 5500 serological screening tests per year. In most of laboratories fourth generation assays are available, while Blood Donation Centers screen the blood both with serological assays and by HIV-RNA detection. Sanitary and Epidemiological Stations and academic laboratories hold the ISO/IEC 17025 or IS0 9001:2001 accreditation, five of the surveyed centers participate in Labquality assurance and two in Quality Control in Molecular Diagnostics programs. Data of control serological testing were received from 21 centers. In the quality control assessment 194 analyses were performed with 91 true negative, 2 false negative, 96 true positive and 5 false positive results. False negative rate of % and false positive rate of 5.2% was noted for this study. Currently, virtually no guidelines related to the HIV-diagnostics quality assurance and control in Poland are in delineated. Development of the national unified quality control system, basing on the central institution is highly desirable. National certification within the frames of the quality control and assurance program should be mandatory for all the diagnostic labs, and aim at improvement of reliability of the result distributed among clinicians and patients.

  17. Clinical experience with (/sup 111/ In) indium chloride scanning in inflammatory diseases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dayem, H.M.; Breen, J.; Leslie, E.V.

    1978-05-01

    Forty-eight patients were scanned with /sup 111/In-chloride in an attempt to identify the cause of fever. Fifteen true positive scans, 30 true negatives, and 3 false negatives were found. Of the 15 true positives, 7 cases of abdominal or pelvic abscess, and 8 cases of alcoholic hepatitis were detected. The 3 false negatives included: (1) an abscess in the anterior abdominal wall; (2) an abscess in the right upper quadrant at the site of a necrotic gallbladder; and (3) a tuberculous abscess of the lumbar spine. Examples from the different categories, pitfalls in interpretation and advantages and disadvantages of scanningmore » with /sup 111/In-chloride will be presented. These studies indicate that /sup 111/In-chloride is a safe, reliable scanning agent for abscesses below the diaphragm especially in patients who cannot undergo adequate bowel preparation.« less

  18. An analysis of false positive reactions occurring with the Captia Syph G EIA.

    PubMed Central

    Ross, J; Moyes, A; Young, H; McMillan, A

    1991-01-01

    AIM--The Captia Syph G enzyme immuno assay (EAI) offers the potential for the rapid automated detection of syphilis antibodies. This study was designed to assess the role of other sexually transmitted diseases (STDs) in producing false positive reactions in the Captia Syph G EIA. The role of rheumatoid factor (RF) as a potential source of false positives was also analysed. METHODS--Patients who attended a genitourinary medicine (GUM) department and gave a false positive reaction with the EIA between 1988 and 1990 were compared with women undergoing antenatal testing and with the control clinic population (EIA negative) over the same time period. The incidence of sexually transmitted disease (STD) in the clinic population and the false positive reactors was measured in relation to gonorrhoea, chlamydia, genital warts, candidiasis, "other conditions not requiring treatment" and "other conditions requiring treatment." Male: female sex ratios were also compared. Ninety two RF positive sera were analysed with the EIA. RESULTS--The rate of false positive reactions did not differ with respect to the diagnosis within the GUM clinic population. The antenatal group of women, however, had a lower incidence of false positive reactions than the GUM clinic group. No RF positive sera were positive on Captia Syph G EIA testing. CONCLUSIONS--There is no cross reaction between Captia Syph G EIA and any specific STD or with RF positive sera. The lower incidence of false positive reactions in antenatal women is unexplained but may be related to physiological changes associated with pregnancy. PMID:1743715

  19. [Evaluation of mycobacterial microscopy and culture results of Sureyyapasa Chest Diseases and Chest Surgery Training and Research Hospital: A 3-year analysis].

    PubMed

    Akduman Alaşehir, Elçin; Balıkçı, Ahmet; Partal, Mualla; Çatmabacak, Gülay; Yaman, Görkem

    2016-09-01

    Effective diagnosis of tuberculosis is of great importance for transmission control and treatment success. The purpose of this study is to evaluate microscopic examination results of Ehrlich-Ziehl Neelsen (EZN) and Auramine-Rhodamine staining methods and automated BACTEC MGIT 960™ system and Löwenstein-Jensen (L-J) culture results of various clinical samples in the light of recent data from the world and Turkey. Specimens that were sent from various clinics to Sureyyapasa Chest Diseases and Chest Surgery Training and Research Hospital Microbiology Laboratory from January 2012 to December 2015 were evaluated retrospectively. From a total of 62456 samples; 60923 (97.5%) were pulmonary and 1533 (2.5%) were non-pulmonary samples, especially pleura. 2853 (4.6%) Acid-resistant bacilli (ARB) positivity was detected and mycobacterial culture positivity was in total 12.2%. 7076 (93%) and 535 (7%) mycobacteria other than tuberculosis (MOTT) strains were isolated. In 356 specimens the cultures were negative in despite the positive ARB results. Considering mycobacterial culture as the gold standard; the sensitivity, specificity, positive and negative predictive values of ARB microscopy were 32.8%, 99.4%, 87.5% and 91.4%, respectively. The contamination rates in total were within acceptable limits being 2.7% for L-J and 3.8% for MGIT. Analysis of our data indicated that the sensitivity of microscopy is low and it should be evaluated together with the mycobacterial culture to rule out tuberculosis infection. With the use of fluorescent staining and also L-J and MGIT broth together for routine culture since 2013; ARB false negativity rate was observed to fall to 51.7% from 74.1% compared to the years. The follow-up of data such as the sensitivity of microscopy, culture positivity, false-positivity and false-negativity rates and contamination values is of great importance in terms of assessing compliance with laboratory quality standards and contributing to the surveillance studies.

  20. Reducing false-positive incidental findings with ensemble genotyping and logistic regression based variant filtering methods.

    PubMed

    Hwang, Kyu-Baek; Lee, In-Hee; Park, Jin-Ho; Hambuch, Tina; Choe, Yongjoon; Kim, MinHyeok; Lee, Kyungjoon; Song, Taemin; Neu, Matthew B; Gupta, Neha; Kohane, Isaac S; Green, Robert C; Kong, Sek Won

    2014-08-01

    As whole genome sequencing (WGS) uncovers variants associated with rare and common diseases, an immediate challenge is to minimize false-positive findings due to sequencing and variant calling errors. False positives can be reduced by combining results from orthogonal sequencing methods, but costly. Here, we present variant filtering approaches using logistic regression (LR) and ensemble genotyping to minimize false positives without sacrificing sensitivity. We evaluated the methods using paired WGS datasets of an extended family prepared using two sequencing platforms and a validated set of variants in NA12878. Using LR or ensemble genotyping based filtering, false-negative rates were significantly reduced by 1.1- to 17.8-fold at the same levels of false discovery rates (5.4% for heterozygous and 4.5% for homozygous single nucleotide variants (SNVs); 30.0% for heterozygous and 18.7% for homozygous insertions; 25.2% for heterozygous and 16.6% for homozygous deletions) compared to the filtering based on genotype quality scores. Moreover, ensemble genotyping excluded > 98% (105,080 of 107,167) of false positives while retaining > 95% (897 of 937) of true positives in de novo mutation (DNM) discovery in NA12878, and performed better than a consensus method using two sequencing platforms. Our proposed methods were effective in prioritizing phenotype-associated variants, and an ensemble genotyping would be essential to minimize false-positive DNM candidates. © 2014 WILEY PERIODICALS, INC.

  1. Reducing false positive incidental findings with ensemble genotyping and logistic regression-based variant filtering methods

    PubMed Central

    Hwang, Kyu-Baek; Lee, In-Hee; Park, Jin-Ho; Hambuch, Tina; Choi, Yongjoon; Kim, MinHyeok; Lee, Kyungjoon; Song, Taemin; Neu, Matthew B.; Gupta, Neha; Kohane, Isaac S.; Green, Robert C.; Kong, Sek Won

    2014-01-01

    As whole genome sequencing (WGS) uncovers variants associated with rare and common diseases, an immediate challenge is to minimize false positive findings due to sequencing and variant calling errors. False positives can be reduced by combining results from orthogonal sequencing methods, but costly. Here we present variant filtering approaches using logistic regression (LR) and ensemble genotyping to minimize false positives without sacrificing sensitivity. We evaluated the methods using paired WGS datasets of an extended family prepared using two sequencing platforms and a validated set of variants in NA12878. Using LR or ensemble genotyping based filtering, false negative rates were significantly reduced by 1.1- to 17.8-fold at the same levels of false discovery rates (5.4% for heterozygous and 4.5% for homozygous SNVs; 30.0% for heterozygous and 18.7% for homozygous insertions; 25.2% for heterozygous and 16.6% for homozygous deletions) compared to the filtering based on genotype quality scores. Moreover, ensemble genotyping excluded > 98% (105,080 of 107,167) of false positives while retaining > 95% (897 of 937) of true positives in de novo mutation (DNM) discovery, and performed better than a consensus method using two sequencing platforms. Our proposed methods were effective in prioritizing phenotype-associated variants, and ensemble genotyping would be essential to minimize false positive DNM candidates. PMID:24829188

  2. The added value of using mutational profiling in addition to cytology in diagnosing aggressive pancreaticobiliary disease: review of clinical cases at a single center

    PubMed Central

    2014-01-01

    Background This study aimed to better understand the supporting role that mutational profiling (MP) of DNA from microdissected cytology slides and supernatant specimens may play in the diagnosis of malignancy in fine-needle aspirates (FNA) and biliary brushing specimens from patients with pancreaticobiliary masses. Methods Cytology results were examined in a total of 30 patients with associated surgical (10) or clinical (20) outcomes. MP of DNA from microdissected cytology slides and from discarded supernatant fluid was analyzed in 26 patients with atypical, negative or indeterminate cytology. Results Cytology correctly diagnosed aggressive disease in 4 patients. Cytological diagnoses for the remaining 26 were as follows: 16 negative (9 false negative), 9 atypical, 1 indeterminate. MP correctly determined aggressive disease in 1 false negative cytology case and confirmed a negative cytology diagnosis in 7 of 7 cases of non-aggressive disease. Of the 9 atypical cytology cases, MP correctly diagnosed 7 as positive and 1 as negative for aggressive disease. One specimen that was indeterminate by cytology was correctly diagnosed as non-aggressive by MP. When first line malignant (positive) cytology results were combined with positive second line MP results, 12/21 cases of aggressive disease were identified, compared to 4/21 cases identified by positive cytology alone. Conclusions When first line cytology results were uncertain (atypical), questionable (negative), or not possible (non-diagnostic/indeterminate), MP provided additional information regarding the presence of aggressive disease. When used in conjunction with first line cytology, MP increased detection of aggressive disease without compromising specificity in patients that were difficult to diagnose by cytology alone. PMID:25084836

  3. [Evaluation of performance and false positivity of Mediace RPR test that uses a chemistry autoanalyzer].

    PubMed

    Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young

    2008-08-01

    We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.

  4. Impact of data fragmentation across healthcare centers on the accuracy of a high-throughput clinical phenotyping algorithm for specifying subjects with type 2 diabetes mellitus

    PubMed Central

    Wei, Wei-Qi; Leibson, Cynthia L; Ransom, Jeanine E; Kho, Abel N; Caraballo, Pedro J; Chai, High Seng; Yawn, Barbara P; Pacheco, Jennifer A

    2012-01-01

    Objective To evaluate data fragmentation across healthcare centers with regard to the accuracy of a high-throughput clinical phenotyping (HTCP) algorithm developed to differentiate (1) patients with type 2 diabetes mellitus (T2DM) and (2) patients with no diabetes. Materials and methods This population-based study identified all Olmsted County, Minnesota residents in 2007. We used provider-linked electronic medical record data from the two healthcare centers that provide >95% of all care to County residents (ie, Olmsted Medical Center and Mayo Clinic in Rochester, Minnesota, USA). Subjects were limited to residents with one or more encounter January 1, 2006 through December 31, 2007 at both healthcare centers. DM-relevant data on diagnoses, laboratory results, and medication from both centers were obtained during this period. The algorithm was first executed using data from both centers (ie, the gold standard) and then from Mayo Clinic alone. Positive predictive values and false-negative rates were calculated, and the McNemar test was used to compare categorization when data from the Mayo Clinic alone were used with the gold standard. Age and sex were compared between true-positive and false-negative subjects with T2DM. Statistical significance was accepted as p<0.05. Results With data from both medical centers, 765 subjects with T2DM (4256 non-DM subjects) were identified. When single-center data were used, 252 T2DM subjects (1573 non-DM subjects) were missed; an additional false-positive 27 T2DM subjects (215 non-DM subjects) were identified. The positive predictive values and false-negative rates were 95.0% (513/540) and 32.9% (252/765), respectively, for T2DM subjects and 92.6% (2683/2898) and 37.0% (1573/4256), respectively, for non-DM subjects. Age and sex distribution differed between true-positive (mean age 62.1; 45% female) and false-negative (mean age 65.0; 56.0% female) T2DM subjects. Conclusion The findings show that application of an HTCP algorithm using data from a single medical center contributes to misclassification. These findings should be considered carefully by researchers when developing and executing HTCP algorithms. PMID:22249968

  5. Fusion of Computed Tomography and PROPELLER Diffusion-Weighted Magnetic Resonance Imaging for the Detection and Localization of Middle Ear Cholesteatoma.

    PubMed

    Locketz, Garrett D; Li, Peter M M C; Fischbein, Nancy J; Holdsworth, Samantha J; Blevins, Nikolas H

    2016-10-01

    A method to optimize imaging of cholesteatoma by combining the strengths of available modalities will improve diagnostic accuracy and help to target treatment. To assess whether fusing Periodically Rotated Overlapping Parallel Lines With Enhanced Reconstruction (PROPELLER) diffusion-weighted magnetic resonance imaging (DW-MRI) with corresponding temporal bone computed tomography (CT) images could increase cholesteatoma diagnostic and localization accuracy across 6 distinct anatomical regions of the temporal bone. Case series and preliminary technology evaluation of adults with preoperative temporal bone CT and PROPELLER DW-MRI scans who underwent surgery for clinically suggested cholesteatoma at a tertiary academic hospital. When cholesteatoma was encountered surgically, the precise location was recorded in a diagram of the middle ear and mastoid. For each patient, the 3 image data sets (CT, PROPELLER DW-MRI, and CT-MRI fusion) were reviewed in random order for the presence or absence of cholesteatoma by an investigator blinded to operative findings. If cholesteatoma was deemed present on review of each imaging modality, the location of the lesion was mapped presumptively. Image analysis was then compared with surgical findings. Twelve adults (5 women and 7 men; median [range] age, 45.5 [19-77] years) were included. The use of CT-MRI fusion had greater diagnostic sensitivity (0.88 vs 0.75), positive predictive value (0.88 vs 0.86), and negative predictive value (0.75 vs 0.60) than PROPELLER DW-MRI alone. Image fusion also showed increased overall localization accuracy when stratified across 6 distinct anatomical regions of the temporal bone (localization sensitivity and specificity, 0.76 and 0.98 for CT-MRI fusion vs 0.58 and 0.98 for PROPELLER DW-MRI). For PROPELLER DW-MRI, there were 15 true-positive, 45 true-negative, 1 false-positive, and 11 false-negative results; overall accuracy was 0.83. For CT-MRI fusion, there were 20 true-positive, 45 true-negative, 1 false-positive, and 6 false-negative results; overall accuracy was 0.90. The poor anatomical spatial resolution of DW-MRI makes precise localization of cholesteatoma within the middle ear and mastoid a diagnostic challenge. This study suggests that the bony anatomic detail obtained via CT coupled with the excellent sensitivity and specificity of PROPELLER DW-MRI for cholesteatoma can improve both preoperative identification and localization of disease over DW-MRI alone.

  6. FDG-PET/CT can rule out malignancy in patients with vocal cord palsy.

    PubMed

    Thomassen, Anders; Nielsen, Anne Lerberg; Lauridsen, Jeppe Kiilerich; Blomberg, Björn Alexander; Hess, Søren; Petersen, Henrik; Johansen, Allan; Asmussen, Jon Thor; Sørensen, Jesper Roed; Johansen, Jørgen; Godballe, Christian; Høilund-Carlsen, Poul Flemming

    2014-01-01

    The aim was to investigate the performance of (18)F-fluorodeoxyglucose PET/CT to rule out malignancy in patients with confirmed vocal cord palsy (VCP). Between January 2011 and June 2013, we retrospectively included consecutive patients referred to PET/CT with paresis or paralysis of one or both vocal cords. PET/CT results were compared to clinical workup and histopathology. The study comprised 65 patients (32 females) with a mean age of 66±12 years (range 37-89). Eleven patients (17%) had antecedent cancer. Twenty-seven (42%) were diagnosed with cancer during follow-up. The palsy was right-sided in 24 patients, left-sided in 37, and bilateral in 4. Median follow-up was 7 months (interquartile range 4-11 months). Patients without cancer were followed for at least three months. PET/CT suggested a malignancy in 35 patients (27 true positives, 8 false positives) and showed none in 30 (30 true negatives, 0 false negatives). Thus, the sensitivity, specificity, positive and negative predictive values, and accuracy were (95% confidence intervals in parenthesis): 100% (88%-100%), 79% (64%-89%), 77% (61%-88%), 100% (89%-100%), and 88% (78%-94%), respectively. Sixteen patients had palliative treatment, while 11 were treated with curative intent, emphasising the severity of VCP and the need for a rapid and accurate diagnostic work-up. In this retrospective survey, biopsy proven malignancy (whether newly diagnosed or relapsed) was the cause of VCP in almost half of patients (42%). PET/CT had a high sensitivity (100%) with a relatively high false positive rate, but was excellent in ruling out malignancy (negative predictive value 100%).

  7. Screening for depression in advanced disease: psychometric properties, sensitivity, and specificity of two items of the Palliative Care Outcome Scale (POS).

    PubMed

    Antunes, Bárbara; Murtagh, Fliss; Bausewein, Claudia; Harding, Richard; Higginson, Irene J

    2015-02-01

    Depression is common among patients with advanced disease but often difficult to detect. To assess the Palliative care Outcome Scale (POS) (10 items) against the Geriatric Depression Scale (GDS)-10 total score and the Hospital Anxiety and Depression Scale (HADS)-Depression subscale total score and determine if the POS has appropriate items to screen for depression among people with advanced disease. This was a secondary analysis performed on five studies. Four psychometric properties were assessed: data quality, scaling assumptions, acceptability, and internal consistency (reliability). Receiver operating characteristic (ROC) curves were used to determine the area under the curve. Sensitivity, specificity, positive and negative predictive values, false positive and negative rates, and positive and negative likelihood ratios were computed. The overall sample had 416 patients from Germany and England: 144 had cancer and 267 had nonmalignant conditions. Prevalence of depression across the sample was 17.5%. Floor and ceiling effects were rare. Cronbach's alpha coefficients for POS items 7 and 8 summed, GDS-10 and HADS-Depression items varied: 0.61 (heart failure) and 0.80 (cancer). Two items combined (Item 7-feeling depressed and Item 8-feeling good about yourself) consistently presented the highest area under the ROC curve, ranging from 0.76 (95% CI 0.60, 0.93) (Germany, lung cancer) to 0.97 (95% CI 0.91, 1.0) (heart failure), highest negative predictive value, and lowest false negative rate. For the overall sample, the cutoff 2/3 presented a negative predictive value of 89.4% (95% CI 84.7, 92.8) and false negative rate of 10.6 (95% CI 7.2, 15.3). POS items 7 and 8 summed are potentially useful to screen for depression in advanced disease populations. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  8. Critical Analysis of the Mathematical Formalism of Theoretical Physics. V. Foundations of the Theory of Negative Numbers

    NASA Astrophysics Data System (ADS)

    Kalanov, Temur Z.

    2015-04-01

    Analysis of the foundations of the theory of negative numbers is proposed. The unity of formal logic and of rational dialectics is methodological basis of the analysis. Statement of the problem is as follows. As is known, point O in the Cartesian coordinate system XOY determines the position of zero on the scale. The number ``zero'' belongs to both the scale of positive numbers and the scale of negative numbers. In this case, the following formallogical contradiction arises: the number 0 is both positive number and negative number; or, equivalently, the number 0 is neither positive number nor negative number, i.e. number 0 has no sign. Then the following question arises: Do negative numbers exist in science and practice? A detailed analysis of the problem shows that negative numbers do not exist because the foundations of the theory of negative numbers contrary to the formal-logical laws. It is proved that: (a) all numbers have no signs; (b) the concepts ``negative number'' and ``negative sign of number'' represent a formallogical error; (c) signs ``plus'' and ``minus'' are only symbols of mathematical operations. The logical errors determine the essence of the theory of negative numbers: the theory of negative number is a false theory.

  9. Screening for acute HIV infection in South Africa: finding acute and chronic disease

    PubMed Central

    Bassett, Ingrid V.; Chetty, Senica; Giddy, Janet; Reddy, Shabashini; Bishop, Karen; Lu, Zhigang; Losina, Elena; Freedberg, Kenneth A.; Walensky, Rochelle P.

    2010-01-01

    Background The yield of screening for acute HIV infection among general medical patients in resource-scarce settings remains unclear. Our objective was to evaluate a strategy of pooled HIV plasma RNA to diagnose acute HIV infection in patients with negative or discordant rapid HIV antibody tests in Durban, South Africa. Methods We prospectively enrolled patients with negative or discordant rapid HIV antibody tests from a routine HIV screening program in an outpatient department in Durban with an HIV prevalence of 48%. Study participants underwent venipuncture for pooled qualitative HIV RNA, and if positive, quantitative RNA, enzyme immunoassay and Western Blot (WB). Patients with negative or indeterminate WB and positive quantitative HIV RNA were considered acutely infected. Those with chronic infection (positive RNA and WB) despite negative or discordant rapid HIV tests were considered false negative rapid antibody tests. Results Nine hundred ninety-four participants were enrolled with either negative (N=976) or discordant (N=18) rapid test results. Eleven (1.1%, 95% CI: 0.6–2.0%) had acute HIV infection. Of the 994 patients, an additional 20 (2.0%, 95% CI: 1.3–.3.1%) had chronic HIV infection (false negative rapid test). Conclusions One percent of outpatients with negative or discordant rapid HIV tests in Durban, South Africa had acute HIV infection readily detectable through pooled serum HIV RNA screening. Pooled RNA testing also identified an additional 2% of patients with chronic HIV infection. HIV RNA screening has the potential to identify both acute and chronic HIV infections that are otherwise missed by standard HIV testing algorithms. PMID:20553336

  10. Axillary lymph node metastases in patients with breast carcinomas: assessment with nonenhanced versus uspio-enhanced MR imaging.

    PubMed

    Memarsadeghi, Mazda; Riedl, Christopher C; Kaneider, Andreas; Galid, Arik; Rudas, Margaretha; Matzek, Wolfgang; Helbich, Thomas H

    2006-11-01

    To prospectively assess the accuracy of nonenhanced versus ultrasmall superparamagnetic iron oxide (USPIO)-enhanced magnetic resonance (MR) imaging for depiction of axillary lymph node metastases in patients with breast carcinoma, with histopathologic findings as reference standard. The study was approved by the university ethics committee; written informed consent was obtained. Twenty-two women (mean age, 60 years; range, 40-79 years) with breast carcinomas underwent nonenhanced and USPIO-enhanced (2.6 mg of iron per kilogram of body weight intravenously administered) transverse T1-weighted and transverse and sagittal T2-weighted and T2*-weighted MR imaging in adducted and elevated arm positions. Two experienced radiologists, blinded to the histopathologic findings, analyzed images of axillary lymph nodes with regard to size, morphologic features, and USPIO uptake. A third independent radiologist served as a tiebreaker if consensus between two readers could not be reached. Visual and quantitative analyses of MR images were performed. Sensitivity, specificity, and accuracy values were calculated. To assess the effect of USPIO after administration, signal-to-noise ratio (SNR) changes were statistically analyzed with repeated-measurements analysis of variance (mixed model) for MR sequences. At nonenhanced MR imaging, of 133 lymph nodes, six were rated as true-positive, 99 as true-negative, 23 as false-positive, and five as false-negative. At USPIO-enhanced MR imaging, 11 lymph nodes were rated as true-positive, 120 as true-negative, two as false-positive, and none as false-negative. In two metastatic lymph nodes in two patients with more than one metastatic lymph node, a consensus was not reached. USPIO-enhanced MR imaging revealed a node-by-node sensitivity, specificity, and accuracy of 100%, 98%, and 98%, respectively. At USPIO-enhanced MR imaging, no metastatic lymph nodes were missed on a patient-by-patient basis. Significant interactions indicating differences in the decrease of SNR values for metastatic and nonmetastatic lymph nodes were found for all sequences (P < .001 to P = .022). USPIO-enhanced MR imaging appears valuable for assessment of axillary lymph node metastases in patients with breast carcinomas and is superior to nonenhanced MR imaging.

  11. Comparative diagnostic value of 18F-fluoride PET-CT versus MRI for skull-base bone invasion in nasopharyngeal carcinoma.

    PubMed

    Le, Yali; Chen, Yu; Zhou, Fan; Liu, Guangfu; Huang, Zhanwen; Chen, Yue

    2016-10-01

    This study compared the diagnostic value of F-fluoride PET-computed tomography (PET-CT) and MRI in skull-base bone erosion in nasopharyngeal carcinoma (NPC) patients. A total of 93 patients with biopsy-confirmed NPC were enrolled, including 68 men and 25 women between 23 and 74 years of age. All patients were evaluated by both F-fluoride PET-CT and MRI, and the interval between the two imaging examinations was less than 20 days. The patients received no treatment either before or between scans. The studies were interpreted by two nuclear medicine physicians or two radiologists with more than 10 years of professional experience who were blinded to both the diagnosis and the results of the other imaging studies. The reference standard was skull-base bone erosion at a 20-week follow-up imaging study. On the basis of the results of the follow-up imaging studies, 52 patients showed skull-base bone erosion. The numbers of true positives, false positives, true negatives, and false negatives with F-fluoride PET-CT were 49, 4, 37, and 3, respectively. The numbers of true positives, false positives, true negatives, and false negatives with MRI were 46, 5, 36, and 6, respectively. The sensitivity, specificity, and crude accuracy of F-fluoride PET-CT were 94.23, 90.24, and 92.47%, respectively; for MRI, these values were 88.46, 87.80, and 88.17%. Of the 52 patients, 43 showed positive findings both on F-fluoride PET-CT and on MRI. Within the patient cohort, F-fluoride PET-CT and MRI detected 178 and 135 bone lesions, respectively. Both F-fluoride PET-CT and MRI have high sensitivity, specificity, and crude accuracy for detecting skull-base bone invasion in patients with NPC. F-fluoride PET-CT detected more lesions than did MRI in the skull-base bone. This suggests that F-fluoride PET-CT has a certain advantage in evaluating the skull-base bone of NPC patients. Combining the two methods could improve the diagnostic accuracy of skull-base bone invasion for NPC.

  12. Unreliable alcohol testing in a shipping safety programme.

    PubMed

    Helander, Anders; Hagelberg, Charlotte Asker; Beck, Olof; Petrini, Björn

    2009-08-10

    Within a maritime alcohol and drug testing programme, a case showing an unphysiological urine ethanol concentration (235 mmol/L, 10.8 g/L) was found. The sample contained low levels of the ethanol metabolites ethyl glucuronide (EtG) and ethyl sulphate (EtS) which confirmed prior drinking, but also tested positive for the fermenting yeast Candida albicans which suggested post-sampling ethanol formation. This and other questionable cases prompted investigation of the suitability of urine alcohol testing for the intended application. Besides the routine measurements of ethanol, illicit drugs and creatinine, randomly selected ethanol-positive and ethanol-negative urines collected within the maritime programme were checked for the presence of EtG and EtS and for fungal and bacterial growth. Data on sample handling and storage was also gathered. Ten of 15 (67%) ethanol-positive and 4 of 9 (44%) ethanol-negative urines contained yeast and/or bacteria. Among the ethanol-positive cases, 4 (27%) were obviously false positives because EtG and EtS were not detected. Microbial action as the reason for false-high ethanol concentrations was indicated in other cases. When 17 bacteria-infected but fungi-negative urines were supplemented with glucose and stored for 1 week at 21 degrees C, ethanol was formed in 2 specimens containing Escherichia coli and E. coli plus P. aeruginosa. In these samples, EtG was also formed on storage while EtS was not. The routines employed for urine collection and handling within this substance abuse programme caused many false-positive identifications of alcohol use with unintended medico-legal consequences. Unpreserved urines stored without cooling should not be used for alcohol testing, given the high risk for microbial interference.

  13. Prospective evaluation of radionuclide scanning in detection of intestinal necrosis in neonatal necrotizing enterocolitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haase, G.M.; Sfakianakis, G.N.; Lobe, T.E.

    1981-06-01

    The ability of external imaging to demonstrate intestinal infarction in neonatal necrotizing enterocolitis (NEC) was prospectively evaluated. The radiopharmaceutical technetium--99m diphosphonate was injected intravenously and the patients subsequently underwent abdominal scanning. Clinical patient care and interpretation of the images were entirely independent throughout the study. Of 33 studies, 7 were positive, 4 were suspicious, and 22 were negative. One false positive study detected ischemia without transmural infarction. The second false positive scan occurred postoperatively and was due to misinterpretation of the hyperactivity along the surgical incision. None of the suspicious cases had damaged bowel. The two false negative studies clearlymore » failed to demonstrate frank intestinal necrosis. The presence of very small areas of infarction, errors in technical settings, subjective interpretation of scans and delayed clearance of the radionuclide in a critically ill neonate may all limit the accuracy of external abdominal scanning. However, in spite of an error rate of 12%, it is likely that this technique will enhance the present clinical, laboratory, and radiologic parameters of patient management in NEC.« less

  14. The psychological impact of a false-positive screening mammogram in Barcelona.

    PubMed

    Espasa, Rebecca; Murta-Nascimento, Cristiane; Bayés, Ramón; Sala, Maria; Casamitjana, Montserrat; Macià, Francesc; Castells, Xavier

    2012-12-01

    The purpose of this study was to ascertain the psychological impact of mammographic screening for women who receive negative results and for those who need additional non-invasive and invasive complementary investigations to exclude breast cancer (false positives). One hundred fifty women who attended a breast cancer screening programme in Barcelona, aged 50-69 years, were included in this study: 50 with negative results and 100 with false positive mammograms (50 underwent non-invasive and 50 underwent invasive complementary investigations). Participants worried little until they underwent mammography, but worries increased when a telephone call notified the women of the need for further testing. A substantial proportion of women requiring further assessment reported that they were at least somewhat worried about having breast cancer throughout the screening process (P < 0.0001). Nevertheless, levels of anxiety and depression, measured by the Hospital Anxiety and Depression Scale, showed no statistically significant differences among the three groups. In conclusion, although the women showed no psychological morbidity, there is a substantial psychological response in those with an abnormal screening mammogram.

  15. High luminance monochrome vs. color displays: impact on performance and search

    NASA Astrophysics Data System (ADS)

    Krupinski, Elizabeth A.; Roehrig, Hans; Matsui, Takashi

    2011-03-01

    To determine if diagnostic accuracy and visual search efficiency with a high luminance medical-grade color display are equivalent to a high luminance medical-grade monochrome display. Six radiologists viewed DR chest images, half with a solitary pulmonary nodule and half without. Observers reported whether or not a nodule was present and their confidence in that decision. Total viewing time per image was recorded. On a subset of 15 cases eye-position was recorded. Confidence data were analyzed using MRMC ROC techniques. There was no statistically significant difference (F = 0.0136, p = 0.9078) between color (mean Az = 0.8981, se = 0.0065) and monochrome (mean Az = 0.8945, se = 0.0148) diagnostic performance. Total viewing time per image did not differ significantly (F = 0.392, p = 0.5315) as a function of color (mean = 27.36 sec, sd = 12.95) vs monochrome (mean = 28.04, sd = 14.36) display. There were no significant differences in decision dwell times (true and false, positive and negative) overall for color vs monochrome displays (F = 0.133, p = 0.7154). The true positive (TP) and false positive (FP) decisions were associated with the longest dwell times, the false negatives (FN) with slightly shorter dwell times, and the true negative decisions (TN) with the shortest (F = 50.552, p < 0.0001) and these trends were consistent for both color and monochrome displays. Current color medical-grade displays are suitable for primary diagnostic interpretation in clinical radiology.

  16. Preschool children's vision screening in New Zealand: a retrospective evaluation of referral accuracy.

    PubMed

    Langeslag-Smith, Miriam A; Vandal, Alain C; Briane, Vincent; Thompson, Benjamin; Anstice, Nicola S

    2015-11-27

    To assess the accuracy of preschool vision screening in a large, ethnically diverse, urban population in South Auckland, New Zealand. Retrospective longitudinal study. B4 School Check vision screening records (n=5572) were compared with hospital eye department data for children referred from screening due to impaired acuity in one or both eyes who attended a referral appointment (n=556). False positive screens were identified by comparing screening data from the eyes that failed screening with hospital data. Estimation of false negative screening rates relied on data from eyes that passed screening. Data were analysed using logistic regression modelling accounting for the high correlation between results for the two eyes of each child. Positive predictive value of the preschool vision screening programme. Screening produced high numbers of false positive referrals, resulting in poor positive predictive value (PPV=31%, 95% CI 26% to 38%). High estimated negative predictive value (NPV=92%, 95% CI 88% to 95%) suggested most children with a vision disorder were identified at screening. Relaxing the referral criteria for acuity from worse than 6/9 to worse than 6/12 improved PPV without adversely affecting NPV. The B4 School Check generated numerous false positive referrals and consequently had a low PPV. There is scope for reducing costs by altering the visual acuity criterion for referral. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Classification of radiological errors in chest radiographs, using support vector machine on the spatial frequency features of false- negative and false-positive regions

    NASA Astrophysics Data System (ADS)

    Pietrzyk, Mariusz W.; Donovan, Tim; Brennan, Patrick C.; Dix, Alan; Manning, David J.

    2011-03-01

    Aim: To optimize automated classification of radiological errors during lung nodule detection from chest radiographs (CxR) using a support vector machine (SVM) run on the spatial frequency features extracted from the local background of selected regions. Background: The majority of the unreported pulmonary nodules are visually detected but not recognized; shown by the prolonged dwell time values at false-negative regions. Similarly, overestimated nodule locations are capturing substantial amounts of foveal attention. Spatial frequency properties of selected local backgrounds are correlated with human observer responses either in terms of accuracy in indicating abnormality position or in the precision of visual sampling the medical images. Methods: Seven radiologists participated in the eye tracking experiments conducted under conditions of pulmonary nodule detection from a set of 20 postero-anterior CxR. The most dwelled locations have been identified and subjected to spatial frequency (SF) analysis. The image-based features of selected ROI were extracted with un-decimated Wavelet Packet Transform. An analysis of variance was run to select SF features and a SVM schema was implemented to classify False-Negative and False-Positive from all ROI. Results: A relative high overall accuracy was obtained for each individually developed Wavelet-SVM algorithm, with over 90% average correct ratio for errors recognition from all prolonged dwell locations. Conclusion: The preliminary results show that combined eye-tracking and image-based features can be used for automated detection of radiological error with SVM. The work is still in progress and not all analytical procedures have been completed, which might have an effect on the specificity of the algorithm.

  18. A novel gamma-fitting statistical method for anti-drug antibody assays to establish assay cut points for data with non-normal distribution.

    PubMed

    Schlain, Brian; Amaravadi, Lakshmi; Donley, Jean; Wickramasekera, Ananda; Bennett, Donald; Subramanyam, Meena

    2010-01-31

    In recent years there has been growing recognition of the impact of anti-drug or anti-therapeutic antibodies (ADAs, ATAs) on the pharmacokinetic and pharmacodynamic behavior of the drug, which ultimately affects drug exposure and activity. These anti-drug antibodies can also impact safety of the therapeutic by inducing a range of reactions from hypersensitivity to neutralization of the activity of an endogenous protein. Assessments of immunogenicity, therefore, are critically dependent on the bioanalytical method used to test samples, in which a positive versus negative reactivity is determined by a statistically derived cut point based on the distribution of drug naïve samples. For non-normally distributed data, a novel gamma-fitting method for obtaining assay cut points is presented. Non-normal immunogenicity data distributions, which tend to be unimodal and positively skewed, can often be modeled by 3-parameter gamma fits. Under a gamma regime, gamma based cut points were found to be more accurate (closer to their targeted false positive rates) compared to normal or log-normal methods and more precise (smaller standard errors of cut point estimators) compared with the nonparametric percentile method. Under a gamma regime, normal theory based methods for estimating cut points targeting a 5% false positive rate were found in computer simulation experiments to have, on average, false positive rates ranging from 6.2 to 8.3% (or positive biases between +1.2 and +3.3%) with bias decreasing with the magnitude of the gamma shape parameter. The log-normal fits tended, on average, to underestimate false positive rates with negative biases as large a -2.3% with absolute bias decreasing with the shape parameter. These results were consistent with the well known fact that gamma distributions become less skewed and closer to a normal distribution as their shape parameters increase. Inflated false positive rates, especially in a screening assay, shifts the emphasis to confirm test results in a subsequent test (confirmatory assay). On the other hand, deflated false positive rates in the case of screening immunogenicity assays will not meet the minimum 5% false positive target as proposed in the immunogenicity assay guidance white papers. Copyright 2009 Elsevier B.V. All rights reserved.

  19. Screening for postnatal depression in Chinese-speaking women using the Hong Kong translated version of the Edinburgh Postnatal Depression Scale.

    PubMed

    Chen, Helen; Bautista, Dianne; Ch'ng, Ying Chia; Li, Wenyun; Chan, Edwin; Rush, A John

    2013-06-01

    The Edinburgh Postnatal Depression Scale (EPDS) may not be a uniformly valid postnatal depression (PND) screen across populations. We evaluated the performance of a Chinese translation of 10-item (HK-EPDS) and six-item (HK-EPDS-6) versions in post-partum women in Singapore. Chinese-speaking post-partum obstetric clinic patients were recruited for this study. They completed the HK-EPDS, from which we derived the six-item HK-EPDS-6. All women were clinically assessed for PND based on Diagnostic and Statistical Manual, Fourth Edition-Text Revision criteria. Receiver-operator curve (ROC) analyses and likelihood ratio computations informed scale cutoff choices. Clinical fitness was judged by thresholds for internal consistency [α ≥ 0.70] and for diagnostic performance by true-positive rate (>85%), false-positive rate (≤10%), positive likelihood ratio (>1), negative likelihood ratio (<0.2), area under the ROC curve (AUC, ≥90%) and effect size (≥0.80). Based on clinical interview, prevalence of PND was 6.2% in 487 post-partum women. HK-EPDS internal consistency was 0.84. At 13 or more cutoff, the true-positive rate was 86.7%, false-positive rate 3.3%, positive likelihood ratio 26.4, negative likelihood ratio 0.14, AUC 94.4% and effect size 0.81. For the HK-EPDS-6, internal consistency was 0.76. At 8 or more cutoff, we found a true-positive rate of 86.7%, false-positive rate 6.6%, positive likelihood ratio 13.2, negative likelihood ration 0.14, AUC 92.9% and effect size 0.98. The HK-EPDS (cutoff ≥13) and HK-EPDS6 (cutoff ≥8) are fit for PND screening for general population post-partum women. The brief six-item version appears to be clinically suitable for quick screening in Chinese speaking women. Copyright © 2013 Wiley Publishing Asia Pty Ltd.

  20. Omitting duodenal biopsy in children with suspected celiac disease and extra-intestinal symptoms.

    PubMed

    Bozzola, Mauro; Meazza, Cristina; Gertosio, Chiara; Pagani, Sara; Larizza, Daniela; Calcaterra, Valeria; Luinetti, Ombretta; Farello, Giovanni; Tinelli, Carmine; Iughetti, Lorenzo

    2017-07-15

    The aim of our study is to evaluate if in children with highly positive serology and HLA-DQ2/DQ8 (triple test, TT) and only extra-intestinal symptoms, it is possible to omit performing an intestinal biopsy for celiac disease (CD) diagnosis, as suggested by the new European Society for Pediatric Gastroenterology, Hepatology and Nutrition ESPGHAN guidelines. In this retrospective study a total of 105 patients, suspected of having CD because of extra-intestinal symptoms and showing serum tissue transglutaminase antibody (anti-tTG) and anti-endomysial antibody (EMA) measurements and HLA genotyping, were considered for the final analysis (33 boys and 72 girls; age range 1.5-17.6 years). Histological findings confirmed diagnosis of CD in 97 (92.4%) patients. Forty-one patients (39%) showed anti-tTG >10 times normal values, positive EMA and positive HLA-DQ2/DQ8 (positive TT). All of them had a diagnosis of CD, therefore there were no false positive cases. Sixty-four patients were negative for the TT. In eight cases, CD was ruled out and these were considered true negative cases. In the remaining 56 negative TT patients, intestinal biopsy confirmed CD diagnosis and they were considered false negatives. Based on these results, specificity for the TT was 100% and sensitivity was 42.3%. On the basis of the present study, diagnosis of CD can be reliably performed without a duodenal biopsy in children with only extra-intestinal symptoms.

  1. Performance characteristics of broth-only cultures after revision total joint arthroplasty.

    PubMed

    Smith, Eric B; Cai, Jenny; Wynne, Rachael; Maltenfort, Mitchell; Good, Robert P

    2014-11-01

    Surgeons frequently obtain intraoperative cultures at the time of revision total joint arthroplasty. The use of broth or liquid medium before applying the sample to the agar medium may be associated with contamination and false-positive cultures; however, the degree to which this is the case is not known. We (1) calculated the performance characteristics of broth-only cultures (sensitivity, specificity, positive predictive value, and negative predictive value) and (2) characterized the organisms identified in broth to determine whether a specific organism showed increased proclivity for true-positive periprosthetic joint infection (PJI). A single-institution retrospective chart review was performed on 257 revision total joint arthroplasties from 2009 through 2010. One hundred ninety (74%) had cultures for review. All culture results, as well as treatment, if any, were documented and patients were followed for a minimum of 1 year for evidence of PJI. Cultures were measured as either positive from the broth only or broth negative. The true diagnosis of infection was determined by the Musculoskeletal Infection Society criteria during the preoperative workup or postoperatively at 1 year for purposes of calculating the performance characteristics of the broth-only culture. The sensitivity, specificity, positive predictive value, and negative predictive value were 19%, 88%, 13%, and 92%, respectively. The most common organism identified was coagulase-negative Staphylococcus (16 of 24 cases, 67%). Coagulase-negative Staphylococcus was present in all three true-positive cases; however, it was also found in 13 of the false-positive cases. The broth-only positive cultures showed poor sensitivity and positive predictive value but good specificity and negative predictive value. The good specificity indicates that it can help to rule in the presence of PJI; however, the poor sensitivity makes broth-only culture an unreliable screening test. We recommend that broth-only culture results be carefully scrutinized and decisions on the diagnosis and treatment of infection should be based specifically on the Musculoskeletal Infection Society criteria. Level IV, diagnostic study. See Instructions for Authors for a complete description of levels of evidence.

  2. Contamination with HIV antibody may be responsible for false positive results in specimens tested on automated platforms running HIV 4th generation assays in a region of high HIV prevalence.

    PubMed

    Hardie, Diana Ruth; Korsman, Stephen N; Hsiao, Nei-Yuan; Morobadi, Molefi Daniel; Vawda, Sabeehah; Goedhals, Dominique

    2017-01-01

    In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector laboratories, the performance of two automated platforms was compared in a clinical pathology setting, firstly on routine diagnostic specimens and secondly on known sero-negative samples. Firstly, 1181 routine diagnostic specimens were sequentially tested on Siemens and Roche automated 4th generation platforms. HIV viral load, western blot and follow up testing were used to determine the true status of inconclusive specimens. Subsequently, known HIV seronegative samples from a single donor were repeatedly tested on both platforms and an analyser was tested for surface contamination with HIV positive serum to identify how suspected specimen contamination could be occurring. Serial testing of diagnostic specimens yielded 163 weakly positive or discordant results. Only 3 of 163 were conclusively shown to indicate true HIV infection. Specimen contamination with HIV antibody was suspected, based on the following evidence: the proportion of positive specimens increased on repeated passage through the analysers; viral loads were low or undetectable and western blots negative or indeterminate on problem specimens; screen negative, 2nd test positive specimens tested positive when reanalysed on the screening assay; follow up specimens (where available) were negative. Similarly, an increasing number of known negative specimens became (repeatedly) sero-positive on serial passage through one of the analysers. Internal and external analyser surfaces were contaminated with HIV serum, evidence that sample splashes occur during testing. Due to the extreme sensitivity of these assays, contamination with minute amounts of HIV antibody can cause a negative sample to test positive. Better contamination control measures are needed on analysers used in clinical pathology environments, especially in regions where HIV sero-prevalence is high.

  3. Effectiveness of the critical congenital heart disease screening program for early diagnosis of cardiac abnormalities in newborn infants.

    PubMed

    Almawazini, Abdulmajid M; Hanafi, Hamdi K; Madkhali, Hasan A; Majrashi, Noura B

    2017-10-01

    To evaluate the effectiveness of critical congenital heart disease (CCHD) screening program for early diagnosis of cardiac anomalies in newborn infants.  Methods: This is a hospital-based prospective cross-sectional study conducted in the Pediatric and Neonatology Department, King Fahad Hospital at  Albaha, Saudi Arabia, between February 2016 and February 2017. Results: We screened 2961 (95.4%) of 3103 patients in a nursery unit; 142 (4.6%) patients were not screened. The test was positive in 114 (3.9%) patients and negative in 2847 (96.1%). There were 94 (3.2%) false positives and 20 (0.7%) true positives. Critical cardiac defects were diagnosed in 7 (0.2%) patients of all screened infants, and severe pulmonary hypertension was diagnosed in 13 (0.4%) patients. True negative results were found in 2841(96%) patients, and no cardiac defect was diagnosed, whereas false negative results were seen in 6 (0.2%) patients diagnosed with ventricular septal defect. The sensitivity was 77%, and the specificity was very high at 97%, with a positive predictive value of 18%, and a negative predictive value of 99.8% (95% confidence interval 13.78-19.18, p=0.0001). Conclusion: Pulse oximetry was found to be easy, safe, sensitive, and highly specific for diagnosis of CCHD.

  4. Characterisation of false-positive observations in botanical surveys

    PubMed Central

    2017-01-01

    Errors in botanical surveying are a common problem. The presence of a species is easily overlooked, leading to false-absences; while misidentifications and other mistakes lead to false-positive observations. While it is common knowledge that these errors occur, there are few data that can be used to quantify and describe these errors. Here we characterise false-positive errors for a controlled set of surveys conducted as part of a field identification test of botanical skill. Surveys were conducted at sites with a verified list of vascular plant species. The candidates were asked to list all the species they could identify in a defined botanically rich area. They were told beforehand that their final score would be the sum of the correct species they listed, but false-positive errors counted against their overall grade. The number of errors varied considerably between people, some people create a high proportion of false-positive errors, but these are scattered across all skill levels. Therefore, a person’s ability to correctly identify a large number of species is not a safeguard against the generation of false-positive errors. There was no phylogenetic pattern to falsely observed species; however, rare species are more likely to be false-positive as are species from species rich genera. Raising the threshold for the acceptance of an observation reduced false-positive observations dramatically, but at the expense of more false negative errors. False-positive errors are higher in field surveying of plants than many people may appreciate. Greater stringency is required before accepting species as present at a site, particularly for rare species. Combining multiple surveys resolves the problem, but requires a considerable increase in effort to achieve the same sensitivity as a single survey. Therefore, other methods should be used to raise the threshold for the acceptance of a species. For example, digital data input systems that can verify, feedback and inform the user are likely to reduce false-positive errors significantly. PMID:28533972

  5. False Positives in Exoplanet Detection

    NASA Astrophysics Data System (ADS)

    Leuquire, Jacob; Kasper, David; Jang-Condell, Hannah; Kar, Aman; Sorber, Rebecca; Suhaimi, Afiq; KELT (Kilodegree Extremely Little Telescope)

    2018-06-01

    Our team at the University of Wyoming uses a 0.6 m telescope at RBO (Red Buttes Observatory) to help confirm results on potential exoplanet candidates from low resolution, wide field surveys shared by the KELT (Kilodegree Extremely Little Telescope) team. False positives are common in this work. We carry out transit photometry, and this method comes with special types of false positives. The most common false positive seen at the confirmation level is an EB (eclipsing binary). Low resolution images are great in detecting multiple sources for photometric dips in light curves, but they lack the precision to decipher single targets at an accurate level. For example, target star KC18C030621 needed RBO’s photometric precision to determine there was a nearby EB causing exoplanet type light curves. Identifying false positives with our telescope is important work because it helps eliminate the waste of time taken by more expensive telescopes trying to rule out negative candidate stars. It also furthers the identification of other types of photometric events, like eclipsing binaries, so they can be studied on their own.

  6. Oxybuprocaine induces a false-positive response in immunochromatographic SAS Adeno Test.

    PubMed

    Hoshino, Takeshi; Takanashi, Taiji; Okada, Morio; Uchida, Sunao

    2002-04-01

    To investigate whether a solution of oxybuprocaine hydrochloride, 0.4%, results in a false-positive response in an immunochromatographic SAS Adeno Test. Experimental study. Physiologic saline and 2% lidocaine. Each chemical (100 microl) was diluted in a transport medium. Five drops (200 microl) of the resultant solution were dispensed into the round sample well of a test device. Fifteen samples were tested in each group. Ten minutes after the start of the test, a colored line in the "specimen" portion of the test membrane was visually read as positive or negative by a masked technician. No positive reaction was observed in the control groups (physiologic saline and lidocaine). A false-positive reaction was observed in six samples (33.3%) in the oxybuprocaine group. The positive rate was significantly higher in the oxybuprocaine group compared with those in control groups (P = 0.0062, Fisher's extract probability test). Oxybuprocaine may induce a false-positive reaction in an immunochromatographic SAS Adeno Test. We recommend the use of lidocaine, instead of oxybuprocaine, for local anesthesia in taking eye swabs from patients with suspected adenovirus infection.

  7. Use of General-purpose Negation Detection to Augment Concept Indexing of Medical Documents

    PubMed Central

    Mutalik, Pradeep G.; Deshpande, Aniruddha; Nadkarni, Prakash M.

    2001-01-01

    Objectives: To test the hypothesis that most instances of negated concepts in dictated medical documents can be detected by a strategy that relies on tools developed for the parsing of formal (computer) languages—specifically, a lexical scanner (“lexer”) that uses regular expressions to generate a finite state machine, and a parser that relies on a restricted subset of context-free grammars, known as LALR(1) grammars. Methods: A diverse training set of 40 medical documents from a variety of specialties was manually inspected and used to develop a program (Negfinder) that contained rules to recognize a large set of negated patterns occurring in the text. Negfinder's lexer and parser were developed using tools normally used to generate programming language compilers. The input to Negfinder consisted of medical narrative that was preprocessed to recognize UMLS concepts: the text of a recognized concept had been replaced with a coded representation that included its UMLS concept ID. The program generated an index with one entry per instance of a concept in the document, where the presence or absence of negation of that concept was recorded. This information was used to mark up the text of each document by color-coding it to make it easier to inspect. The parser was then evaluated in two ways: 1) a test set of 60 documents (30 discharge summaries, 30 surgical notes) marked-up by Negfinder was inspected visually to quantify false-positive and false-negative results; and 2) a different test set of 10 documents was independently examined for negatives by a human observer and by Negfinder, and the results were compared. Results: In the first evaluation using marked-up documents, 8,358 instances of UMLS concepts were detected in the 60 documents, of which 544 were negations detected by the program and verified by human observation (true-positive results, or TPs). Thirteen instances were wrongly flagged as negated (false-positive results, or FPs), and the program missed 27 instances of negation (false-negative results, or FNs), yielding a sensitivity of 95.3 percent and a specificity of 97.7 percent. In the second evaluation using independent negation detection, 1,869 concepts were detected in 10 documents, with 135 TPs, 12 FPs, and 6 FNs, yielding a sensitivity of 95.7 percent and a specificity of 91.8 percent. One of the words “no,” “denies/denied,” “not,” or “without” was present in 92.5 percent of all negations. Conclusions: Negation of most concepts in medical narrative can be reliably detected by a simple strategy. The reliability of detection depends on several factors, the most important being the accuracy of concept matching. PMID:11687566

  8. Design of a multiplex PCR for Streptococcus pneumoniae, Haemophilus influenzae, Mycoplasma pneumoniae and Chlamydophila pneumoniae to be used on sputum samples.

    PubMed

    Strålin, Kristoffer; Bäckman, Anders; Holmberg, Hans; Fredlund, Hans; Olcén, Per

    2005-02-01

    A multiplex PCR (mPCR) was developed for simultaneous detection of specific genes for Streptococcus pneumoniae (lytA), Mycoplasma pneumoniae (P1), Chlamydophila pneumoniae (ompA), and Haemophilus influenzae (16S rRNA, with verification PCR for P6). When the protocol was tested on 257 bacterial strains belonging to 37 different species, no false negatives and only one false positive were noted. One Streptococcus mitis out of thirty was positive for lytA. In a pilot application study of 81 sputum samples from different patients with suspected lower respiratory tract infection (LRTI), mPCR identified S. pneumoniae in 25 samples, H. influenzae in 29, M. pneumoniae in 3, and C. pneumoniae in 1. All samples culture positive for S. pneumoniae (n=15) and H. influenzae (n=15) were mPCR positive for the same bacteria. In a pilot control study with nasopharyngeal swabs and aspirates from 10 healthy adults, both culture and mPCR were negative. No PCR inhibition was found in any of the mPCR-negative sputum or nasopharyngeal samples. Whether all samples identified as positive by mPCR are truly positive in an aetiological perspective regarding LRTI remains to be evaluated in a well-defined patient material. In conclusion, the mPCR appears to be a promising tool in the aetiological diagnostics of LRTI.

  9. [EXPERIENCE OF STUDY AND POSSIBLE WAYS OF ELIMINATION OF FALSE POSITIVE AND FALSE NEGATIVE RESULTS DURING EXECUTION OF POLYMERASE CHAIN REACTION ON AN EXAMPLE OF JUNIN VIRUS RNA DETECTION].

    PubMed

    Sizikova, T E; Lebedev, V N; Pantyukhov, V B; Borisevich, S V; Merkulov, V A

    2015-01-01

    Experience of study and possible ways of elimination of false positive and false negative results during execution of polymerase chain reaction on an example of Junin virus RNA detection. MATERIALSS AND METHODS: Junin virus--causative agent of Argentine hemorrhagic fever (AHF) strain XJpR37/5787 was obtained from the State collection of pathogenicity group I causative agents of the 48th Central Research Institute. Reagent kit for detection of Junin virus RNA by RT-PCR was developed in the Institute and consists of 4 sets: for isolation of RNA, execution of reverse-transcription reaction, execution of PCR and electrophoretic detection of PCR products. RT-PCR was carried out by a standard technique. Continuous cell cultures of African green monkey Vero B, GMK-AH-1(D) were obtained from the museum of cell culture department of the Centre. An experimental study of the effect of various factors of impact on the sample under investigation ("thawing-freezing", presence of formaldehyde, heparin) on the obtaining of false negative results during Junin virus RNA detection by using RT-PCR was studied. Addition of 0.01% heparin to the samples was shown to completely inhibit PCR. Addition of 0.05% formaldehyde significantly reduces sensitivity of the method. A possibility of reduction of analysis timeframe from 15 to 5 days was shown during detection of the causative agent in samples with low concentration of the latter by growing the samples and subsequent analysis of the material obtained by using RT-PCR. During detection of causative agent by using RT-PCR false negative results could appear in the presence of formaldehyde and heparin in the sample. A possibility of elimination of false negative PCR results due to concentration of the causative agent in the sample under investigation at a level below sensitivity threshold was shown on the example of Junin virus RNA detection by using growing of the pathogen in appropriate accumulation system with subsequent analysis of the material obtained using PCR.

  10. The management of isolated positive syphilis enzyme immunoassay results in HIV-negative patients attending a sexual health clinic.

    PubMed

    Thorley, Nicola; Adebayo, Michael; Smit, Erasmus; Radcliffe, Keith

    2016-08-01

    An unconfirmed positive treponemal enzyme immunoassay (enzyme immunoassay positive, Treponema pallidum particle agglutination negative and rapid plasma reagin negative) presents a clinical challenge to distinguish early syphilis infection from false-positive results. These cases are referred for syphilis line assay (INNO-LIA) and recalled for repeat syphilis serology. We performed a retrospective audit to establish the proportion of HIV-negative cases with unconfirmed positive enzyme immunoassay results, the proportion of these cases that received an INNO-LIA test and repeat syphilis serology testing and reviewed the clinical outcomes; 0.35% (80/22687) cases had an unconfirmed positive treponemal enzyme immunoassay result. Repeat syphilis serology was performed in 80% (64/80) cases, but no additional cases of syphilis were identified. Eighty-eight per cent (70/80) received an INNO-LIA test; 14% (5/37) unconfirmed enzyme immunoassay-positive cases with no prior history of syphilis were confirmed on INNO-LIA assay, supporting a diagnosis of latent syphilis. As a confirmatory treponemal test, the INNO-LIA assay may be more useful than repeat syphilis serological testing. © The Author(s) 2016.

  11. Development of a quantitative loop-mediated isothermal amplification assay for the field detection of Erysiphe necator

    USDA-ARS?s Scientific Manuscript database

    Plant pathogen detection systems have been useful tools to monitor inoculum presence and initiate management schedules. More recently, a LAMP assay was successfully designed for field use in the grape powdery mildew pathosystem; however, false negatives or false positives were prevalent in grower-co...

  12. The sFlt-1/PlGF ratio associates with prolongation and adverse outcome of pregnancy in women with (suspected) preeclampsia: analysis of a high-risk cohort.

    PubMed

    Saleh, Langeza; Verdonk, Koen; Jan Danser, A H; Steegers, Eric A P; Russcher, Henk; van den Meiracker, Anton H; Visser, Willy

    2016-04-01

    To evaluate the additive value of the sFlt-1/PlGF ratio for diagnosing preeclampsia (PE) and predicting prolongation of pregnancy and adverse outcome in a cohort of women with PE or at high risk of PE. Patients with suspected or confirmed clinical PE were recruited. At time of inclusion blood for measurement of sFlt-1and PlGF was taken. Values were determined after delivery. A cut-off ratio of ≥85 was defined as a positive test. A total of 107 patients were included. Of the patients, 62 (58%) met the clinical criteria of PE at time of blood sampling. In 10% of these patients (n=6) the ratio was <85 (false negative), whereas in 7% (n=3) of patients without clinical PE the ratio was ≥85 (false positive), resulting in positive and negative predictive values of 95% and 88% respectively. One patient with false positive ratio developed superimposed PE and 2 developed gestational hypertension, and adverse outcome occurred in all three. An adverse pregnancy outcome was only encountered in 1 of the 6 patients with a false negative ratio. Using a binary regression model with adjustment for gestational age <34 weeks, the adverse outcome risk was 11 times increased on the basis of clinical PE, and 30 times on the basis of an elevated ratio (P=0.036). The additive value of an increased ratio for diagnosing PE is limited since most patients with clinical PE also have a positive ratio. However, an elevated ratio is superior to the clinical diagnosis of PE for predicting an adverse pregnancy outcome. Furthermore, irrespective of clinical PE, a low ratio is inversely correlated with prolongation of pregnancy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. False Positivity of Non-Targeted Infections in Malaria Rapid Diagnostic Tests: The Case of Human African Trypanosomiasis

    PubMed Central

    Gillet, Philippe; Mumba Ngoyi, Dieudonné; Lukuka, Albert; Kande, Viktor; Atua, Benjamin; van Griensven, Johan; Muyembe, Jean-Jacques; Jacobs, Jan; Lejon, Veerle

    2013-01-01

    Background In endemic settings, diagnosis of malaria increasingly relies on the use of rapid diagnostic tests (RDTs). False positivity of such RDTs is poorly documented, although it is especially relevant in those infections that resemble malaria, such as human African trypanosomiasis (HAT). We therefore examined specificity of malaria RDT products among patients infected with Trypanosoma brucei gambiense. Methodology/Principal Findings Blood samples of 117 HAT patients and 117 matched non-HAT controls were prospectively collected in the Democratic Republic of the Congo. Reference malaria diagnosis was based on real-time PCR. Ten commonly used malaria RDT products were assessed including three two-band and seven three-band products, targeting HRP-2, Pf-pLDH and/or pan-pLDH antigens. Rheumatoid factor was determined in PCR negative subjects. Specificity of the 10 malaria RDT products varied between 79.5 and 100% in HAT-negative controls and between 11.3 and 98.8% in HAT patients. For seven RDT products, specificity was significantly lower in HAT patients compared to controls. False positive reactions in HAT were mainly observed for pan-pLDH test lines (specificities between 13.8 and 97.5%), but also occurred frequently for the HRP-2 test line (specificities between 67.9 and 98.8%). The Pf-pLDH test line was not affected by false-positive lines in HAT patients (specificities between 97.5 and 100%). False positivity was not associated to rheumatoid factor, detected in 7.6% of controls and 1.2% of HAT patients. Conclusions/Significance Specificity of some malaria RDT products in HAT was surprisingly low, and constitutes a risk for misdiagnosis of a fatal but treatable infection. Our results show the importance to assess RDT specificity in non-targeted infections when evaluating diagnostic tests. PMID:23638201

  14. Neural network for photoplethysmographic respiratory rate monitoring

    NASA Astrophysics Data System (ADS)

    Johansson, Anders

    2001-10-01

    The photoplethysmographic signal (PPG) includes respiratory components seen as frequency modulation of the heart rate (respiratory sinus arrhythmia, RSA), amplitude modulation of the cardiac pulse, and respiratory induced intensity variations (RIIV) in the PPG baseline. The aim of this study was to evaluate the accuracy of these components in determining respiratory rate, and to combine the components in a neural network for improved accuracy. The primary goal is to design a PPG ventilation monitoring system. PPG signals were recorded from 15 healthy subjects. From these signals, the systolic waveform, diastolic waveform, respiratory sinus arrhythmia, pulse amplitude and RIIV were extracted. By using simple algorithms, the rates of false positive and false negative detection of breaths were calculated for each of the five components in a separate analysis. Furthermore, a simple neural network (NN) was tried out in a combined pattern recognition approach. In the separate analysis, the error rates (sum of false positives and false negatives) ranged from 9.7% (pulse amplitude) to 14.5% (systolic waveform). The corresponding value of the NN analysis was 9.5-9.6%.

  15. Autonomic responses to correct outcomes and interaction errors during single-switch scanning among children with severe spastic quadriplegic cerebral palsy

    PubMed Central

    2014-01-01

    Background The combination of single-switch access technology and scanning is the most promising means of augmentative and alternative communication for many children with severe physical disabilities. However, the physical impairment of the child and the technology’s limited ability to interpret the child’s intentions often lead to false positives and negatives (corresponding to accidental and missed selections, respectively) occurring at rates that frustrate the user and preclude functional communication. Multiple psychophysiological studies have associated cardiac deceleration and increased phasic electrodermal activity with self-realization of errors among able-bodied individuals. Thus, physiological measurements have potential utility at enhancing single-switch access, provided that such prototypical autonomic responses exist in persons with profound disabilities. Methods The present case series investigated the autonomic responses of three pediatric single-switch users with severe spastic quadriplegic cerebral palsy, in the context of a single-switch letter matching activity. Each participant exhibited distinct autonomic responses to activity engagement. Results Our analysis confirmed the presence of the autonomic response pattern of cardiac deceleration and increased phasic electrodermal activity following true positives, false positives and false negatives errors, but not subsequent to true negative outcomes. Conclusions These findings suggest that there may be merit in complementing single-switch input with autonomic measurements to improve augmentative and alternative communications for pediatric access technology users. PMID:24607065

  16. Autonomic responses to correct outcomes and interaction errors during single-switch scanning among children with severe spastic quadriplegic cerebral palsy.

    PubMed

    Leung, Brian; Chau, Tom

    2014-03-08

    The combination of single-switch access technology and scanning is the most promising means of augmentative and alternative communication for many children with severe physical disabilities. However, the physical impairment of the child and the technology's limited ability to interpret the child's intentions often lead to false positives and negatives (corresponding to accidental and missed selections, respectively) occurring at rates that frustrate the user and preclude functional communication. Multiple psychophysiological studies have associated cardiac deceleration and increased phasic electrodermal activity with self-realization of errors among able-bodied individuals. Thus, physiological measurements have potential utility at enhancing single-switch access, provided that such prototypical autonomic responses exist in persons with profound disabilities. The present case series investigated the autonomic responses of three pediatric single-switch users with severe spastic quadriplegic cerebral palsy, in the context of a single-switch letter matching activity. Each participant exhibited distinct autonomic responses to activity engagement. Our analysis confirmed the presence of the autonomic response pattern of cardiac deceleration and increased phasic electrodermal activity following true positives, false positives and false negatives errors, but not subsequent to true negative outcomes. These findings suggest that there may be merit in complementing single-switch input with autonomic measurements to improve augmentative and alternative communications for pediatric access technology users.

  17. Screening for ALK in non-small cell lung carcinomas: 5A4 and D5F3 antibodies perform equally well, but combined use with FISH is recommended.

    PubMed

    Savic, Spasenija; Diebold, Joachim; Zimmermann, Anne-Katrin; Jochum, Wolfram; Baschiera, Betty; Grieshaber, Susanne; Tornillo, Luigi; Bisig, Bettina; Kerr, Keith; Bubendorf, Lukas

    2015-08-01

    Immunohistochemistry (IHC) has become a promising method for pre-screening ALK-rearrangements in non-small cell lung carcinomas (NSCLC). Various ALK antibodies, detection systems and automated immunostainers are available. We therefore aimed to compare the performance of the monoclonal 5A4 (Novocastra, Leica) and D5F3 (Cell Signaling, Ventana) antibodies using two different immunostainers. Additionally we analyzed the accuracy of prospective ALK IHC-testing in routine diagnostics. Seventy-two NSCLC with available ALK FISH results and enriched for FISH-positive carcinomas were retrospectively analyzed. IHC was performed on BenchMarkXT (Ventana) using 5A4 and D5F3, respectively, and additionally with 5A4 on Bond-MAX (Leica). Data from our routine diagnostics on prospective ALK-testing with parallel IHC, using 5A4, and FISH were available from 303 NSCLC. All three IHC protocols showed congruent results. Only 1/25 FISH-positive NSCLC (4%) was false negative by IHC. For all three IHC protocols the sensitivity, specificity, positive (PPV) and negative predictive values (NPV) compared to FISH were 96%, 100%, 100% and 97.8%, respectively. In the prospective cohort 3/32 FISH-positive (9.4%) and 2/271 FISH-negative (0.7%) NSCLC were false negative and false positive by IHC, respectively. In routine diagnostics the sensitivity, specificity, PPV and NPV of IHC compared to FISH were 90.6%, 99.3%, 93.5% and 98.9%, respectively. 5A4 and D5F3 are equally well suited for detecting ALK-rearranged NSCLC. BenchMark and BOND-MAX immunostainers can be used for IHC with 5A4. True discrepancies between IHC and FISH results do exist and need to be addressed when implementing IHC in an ALK-testing algorithm. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Automatic mouse ultrasound detector (A-MUD): A new tool for processing rodent vocalizations.

    PubMed

    Zala, Sarah M; Reitschmidt, Doris; Noll, Anton; Balazs, Peter; Penn, Dustin J

    2017-01-01

    House mice (Mus musculus) emit complex ultrasonic vocalizations (USVs) during social and sexual interactions, which have features similar to bird song (i.e., they are composed of several different types of syllables, uttered in succession over time to form a pattern of sequences). Manually processing complex vocalization data is time-consuming and potentially subjective, and therefore, we developed an algorithm that automatically detects mouse ultrasonic vocalizations (Automatic Mouse Ultrasound Detector or A-MUD). A-MUD is a script that runs on STx acoustic software (S_TOOLS-STx version 4.2.2), which is free for scientific use. This algorithm improved the efficiency of processing USV files, as it was 4-12 times faster than manual segmentation, depending upon the size of the file. We evaluated A-MUD error rates using manually segmented sound files as a 'gold standard' reference, and compared them to a commercially available program. A-MUD had lower error rates than the commercial software, as it detected significantly more correct positives, and fewer false positives and false negatives. The errors generated by A-MUD were mainly false negatives, rather than false positives. This study is the first to systematically compare error rates for automatic ultrasonic vocalization detection methods, and A-MUD and subsequent versions will be made available for the scientific community.

  19. Stress and emotional valence effects on children's versus adolescents' true and false memory.

    PubMed

    Quas, Jodi A; Rush, Elizabeth B; Yim, Ilona S; Edelstein, Robin S; Otgaar, Henry; Smeets, Tom

    2016-01-01

    Despite considerable interest in understanding how stress influences memory accuracy and errors, particularly in children, methodological limitations have made it difficult to examine the effects of stress independent of the effects of the emotional valence of to-be-remembered information in developmental populations. In this study, we manipulated stress levels in 7-8- and 12-14-year-olds and then exposed them to negative, neutral, and positive word lists. Shortly afterward, we tested their recognition memory for the words and false memory for non-presented but related words. Adolescents in the high-stress condition were more accurate than those in the low-stress condition, while children's accuracy did not differ across stress conditions. Also, among adolescents, accuracy and errors were higher for the negative than positive words, while in children, word valence was unrelated to accuracy. Finally, increases in children's and adolescents' cortisol responses, especially in the high-stress condition, were related to greater accuracy but not false memories and only for positive emotional words. Findings suggest that stress at encoding, as well as the emotional content of to-be-remembered information, may influence memory in different ways across development, highlighting the need for greater complexity in existing models of true and false memory formation.

  20. Optimising in situ gamma measurements to identify the presence of radioactive particles in land areas.

    PubMed

    Rostron, Peter D; Heathcote, John A; Ramsey, Michael H

    2014-12-01

    High-coverage in situ surveys with gamma detectors are the best means of identifying small hotspots of activity, such as radioactive particles, in land areas. Scanning surveys can produce rapid results, but the probabilities of obtaining false positive or false negative errors are often unknown, and they may not satisfy other criteria such as estimation of mass activity concentrations. An alternative is to use portable gamma-detectors that are set up at a series of locations in a systematic sampling pattern, where any positive measurements are subsequently followed up in order to determine the exact location, extent and nature of the target source. The preliminary survey is typically designed using settings of detector height, measurement spacing and counting time that are based on convenience, rather than using settings that have been calculated to meet requirements. This paper introduces the basis of a repeatable method of setting these parameters at the outset of a survey, for pre-defined probabilities of false positive and false negative errors in locating spatially small radioactive particles in land areas. It is shown that an un-collimated detector is more effective than a collimated detector that might typically be used in the field. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Evaluation of the on-site immunoassay drug-screening device Triage-TOX in routine forensic autopsy.

    PubMed

    Tominaga, Mariko; Michiue, Tomomi; Maeda, Hitoshi

    2015-11-01

    Instrumental identification of drugs with quantification is essential in forensic toxicology, while on-site immunoassay urinalysis drug-screening devices conveniently provide preliminary information when adequately used. However, suitable or sufficient urine specimens are not always available. The present study evaluated the efficacy of a new on-site immunoassay drug-screening device Triage-TOX (Alere Inc., San Diego, CA, USA), which has recently been developed to provide objective data on the one-step automated processor, using 51 urine and 19 pericardial fluid samples from 66 forensic autopsy cases, compared with Triage-Drug of Abuse (DOA) and Monitect-9. For benzodiazepines, the positive predictive value and specificity of Triage-TOX were higher than those of Triage-DOA; however, sensitivity was higher with Monitect-9, despite frequent false-positives. The results for the other drugs with the three devices also included a few false-negatives and false-positives. These observations indicate the applicability of Triage-TOX in preliminary drug screening using urine or alternative materials in routine forensic autopsy, when a possible false-negative is considered, especially for benzodiazepines, providing objective information; however, the combined use of another device such as Monitect-9 can help minimize misinterpretation prior to instrumental analysis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Finite mixture modeling for vehicle crash data with application to hotspot identification.

    PubMed

    Park, Byung-Jung; Lord, Dominique; Lee, Chungwon

    2014-10-01

    The application of finite mixture regression models has recently gained an interest from highway safety researchers because of its considerable potential for addressing unobserved heterogeneity. Finite mixture models assume that the observations of a sample arise from two or more unobserved components with unknown proportions. Both fixed and varying weight parameter models have been shown to be useful for explaining the heterogeneity and the nature of the dispersion in crash data. Given the superior performance of the finite mixture model, this study, using observed and simulated data, investigated the relative performance of the finite mixture model and the traditional negative binomial (NB) model in terms of hotspot identification. For the observed data, rural multilane segment crash data for divided highways in California and Texas were used. The results showed that the difference measured by the percentage deviation in ranking orders was relatively small for this dataset. Nevertheless, the ranking results from the finite mixture model were considered more reliable than the NB model because of the better model specification. This finding was also supported by the simulation study which produced a high number of false positives and negatives when a mis-specified model was used for hotspot identification. Regarding an optimal threshold value for identifying hotspots, another simulation analysis indicated that there is a discrepancy between false discovery (increasing) and false negative rates (decreasing). Since the costs associated with false positives and false negatives are different, it is suggested that the selected optimal threshold value should be decided by considering the trade-offs between these two costs so that unnecessary expenses are minimized. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Comparison of false-negative/positive results of intraoperative evoked potential monitoring between no and partial neuromuscular blockade in patients receiving propofol/remifentanil-based anesthesia during cerebral aneurysm clipping surgery: A retrospective analysis of 685 patients.

    PubMed

    Kim, Sung-Hoon; Jin, Seok-Joon; Karm, Myong-Hwan; Moon, Young-Jin; Jeong, Hye-Won; Kim, Jae-Won; Ha, Seung-Il; Kim, Joung-Uk

    2016-08-01

    Although the elicited responses of motor evoked potential (MEP) monitoring are very sensitive to suppression by anesthetic agents and muscle relaxants, the use of neuromuscular blockade (NMB) during MEP monitoring is still controversial because of serious safety concerns and diagnostic accuracy. Here, we evaluated the incidence of unacceptable movement and compared false-negative MEP results between no and partial NMB during cerebral aneurysm clipping surgery. We reviewed patient medical records for demographic data, anesthesia regimen, neurophysiology event logs, MEP results, and clinical outcomes. Patients were divided into 2 groups according to the intraoperative use of NMB: no NMB group (n = 276) and partial NMB group (n = 409). We compared the diagnostic accuracy of MEP results to predict postoperative outcomes between both groups. Additionally, we evaluated unwanted patient movement during MEP monitoring in both groups. Of the 685 patients, 622 (90.8%) manifested no intraoperative changes in MEP and no postoperative motor deficits. Twenty patients showed postoperative neurologic deficits despite preserved intraoperative MEP. False-positive MEP results were 3.6% in the no NMB group and 3.9% in the partial NMB group (P = 1.00). False-negative MEP results were 1.1% in the no NMB group and 4.2% in the partial NMB group (P = 0.02). No spontaneous movement or spontaneous respiration was observed in either group. Propofol/remifentanil-based anesthesia without NMB decreases the stimulation intensity of MEPs, which may reduce the false-negative ratio of MEP monitoring during cerebral aneurysm surgery. Our anesthetic protocol enabled reliable intraoperative MEP recording and patient immobilization during cerebral aneurysm clipping surgery.

  4. Use of the Abbott Architect HIV antigen/antibody assay in a low incidence population.

    PubMed

    Dubravac, Terry; Gahan, Thomas F; Pentella, Michael A

    2013-12-01

    With the availability of 4th generation HIV diagnostic tests which are capable of detecting acute infection, Iowa evaluated the 3rd and 4th generation HIV test and compared the performance of these products in a low incidence population. This study was conducted to evaluate the performance of an HIV antigen/antibody combination (4th generation) assay compared to an EIA 3rd generation assay. Over a 4 month period, 2037 specimens submitted for HIV screening were tested by Bio-Rad GS HIV-1/HIV-2 Plus O EIA and the Abbott Architect i1000SR HIV Ag/Ab Combo. The performance characteristics of sensitivity, specificity, positive predictive value and negative predictive value were determined. Of the 2037 specimens tested, there were 13 (0.64%) true positives detected. None of the positive specimens were from patients in the acute phase of infection. The Abbott antigen/antibody combo assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.85%, 81.25%, and 100% respectively. The Bio-Rad EIA assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.80%, 76.47% and 100%, respectively. The EIA had four false positive results which tested negative by the antigen/antibody assay and western blot. In a low-incidence state where early infections are less commonly encountered, the EIA assay and the antigen/antibody assay performed with near equivalency. The antigen/antibody assay had one less false positive result. While no patients were detected in the acute stage of infection, the use of the antigen/antibody assay presents the opportunity to detect an infected patient sooner and prevent transmission to others. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Adenocarcinoma with BAC Features Presented as the Nonsolid Nodule Is Prone to Be False-Negative on 18F-FDG PET/CT

    PubMed Central

    Wu, Hu-bing; Wang, Lijuan; Wang, Quan-shi; Han, Yan-jian; Li, Hong-sheng; Zhou, Wen-lan; Tian, Ying

    2015-01-01

    Purpose. The present study investigated which type of adenocarcinoma with BAC features was prone to be false-negative on 18F-FDG PET/CT. Materials and Methods. A retrospective study was performed on 51 consecutive patients with localized adenocarcinoma with BAC features. CT and PET were assessed for lesion size, GGO percentage, and SUVmax. Lesions with FDG uptake the same as or more than mediastinal blood-pool activity were considered as PET-positive. Results. Of the 51 cases, 19.6% presented as pure GGO nodules, 31.4% as mixed nodules, and 49.0% as solid nodules. None of the pure GGO nodules was 18F-FDG avid, compared with 37.5% of mixed nodules and 96.0% of solid nodules (χ 2 = 31.55, P = 0.000). In the mixed nodule group, SUVmax was negatively correlated with GGO percentage (r = −0.588; P = 0.021). The positive detection rate of 18F-FDG PET/CT was 50.0%, 55.6%, and 100% in tumors 1.1–2.0 cm, 2.1–3.0 cm, and >3.0 cm in diameter, respectively (χ 2 = 5.815, P = 0.055). General linear model factor analysis showed that the GGO was an important factor contributing to false-negative PET/CT results (F = 23.992, P = 0.000), but lesion size was not (F = 0.602, P = 0.866). Conclusions. The present study indicated that the adenocarcinoma with BAC features presented as nonsolid nodule is prone to be false negative on 18F-FDG PET/CT. PMID:25879020

  6. Developmental Differences across Middle Childhood in Memory and Suggestibility for Negative and Positive Events.

    PubMed

    Paz-Alonso, Pedro M; Goodman, Gail S

    2016-01-01

    In the present study, we investigated age differences in children's eyewitness memory and suggestibility for negative and positive events that children often experience during middle childhood. We first examined 216 ratings by children aged 8-12 years of the frequency and intensity of personal negative and positive experiences (Study 1). Based on those ratings, videotapes depicting the most frequent and intense negative (an accident) and positive (a family excursion) events were developed. A new sample of 227 children aged 8-12 years was tested for recognition memory of the videotapes using the three-stage post-event misinformation procedure (Study 2). Compared with 8- to 9-year-olds, 10- to 12-year-olds exhibited less memory malleability and less compliance with false information. Age improvements in recognition accuracy were also evident for children who watched the negative event, but not for those who watched the positive event. Compliance predicted misinformation effects, particularly in regard to peripheral details. Thus, using ecologically representative emotional events, age differences in suggestibility and memory accuracy emerged, especially for negative events.Theoretical and forensic implications concerning children's eyewitness memory and suggestibility are discussed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Evaluation of negative results of BacT/Alert 3D automated blood culture system.

    PubMed

    Kocoglu, M Esra; Bayram, Aysen; Balci, Iclal

    2005-06-01

    Although automated continuous-monitoring blood culture systems are both rapid and sensitive, false-positive and false-negative results still occur. The objective of this study, then, was to evaluate negative results occurring with BacT/Alert 3D blood culture systems. A total of 1032 samples were cultured with the BacT/Alert 3D automated blood culture system, using both aerobic (FA) and anaerobic (FN) [corrected] media, and 128 of these samples yielded positive results. A total of 904 negative blood samples were then subcultured in 5% sheep blood agar, eosin methylene blue, chocolate agar, and sabouraud-dextrose agar. Organisms growing on these subcultures were subsequently identified using both Vitek32 (bioMerieux, Durham, NC) and conventional methods. Twenty four (2.6%) of the 904 subcultures grew on the subculture media. The majority (83.3%) of these were determined to be gram-positive microorganisms. Fourteen (58.3%) were coagulase-negative staphylococci, two (8.3%) were Bacillus spp., one (4.2%) was Staphylococcus aureus, and one (4.2%) was identified as Enterococcus faecium. Streptococcus pneumoniae and Neisseria spp. were isolated together in two (8.3%) vials. Gram-negative microorganisms comprised 12.5% of the subcultures, of which two (8.3%) were found to be Pseudomonas aeruginosa, and one (4.2%) was Pseudomonas fluorescens. The other isolate (4.2%) was identified as Candida albicans. We conclude that the subculture of negative results is valuable in the BacT/Alert 3D system, especially in situations in which only one set of blood cultures is taken.

  8. Evaluation of surveillance case definition in the diagnosis of leptospirosis, using the Microscopic Agglutination Test: a validation study.

    PubMed

    Dassanayake, Dinesh L B; Wimalaratna, Harith; Agampodi, Suneth B; Liyanapathirana, Veranja C; Piyarathna, Thibbotumunuwe A C L; Goonapienuwala, Bimba L

    2009-04-22

    Leptospirosis is endemic in both urban and rural areas of Sri Lanka and there had been many out breaks in the recent past. This study was aimed at validating the leptospirosis surveillance case definition, using the Microscopic Agglutination Test (MAT). The study population consisted of patients with undiagnosed acute febrile illness who were admitted to the medical wards of the Teaching Hospital Kandy, from 1st July 2007 to 31st July 2008. The subjects were screened to diagnose leptospirosis according to the leptospirosis case definition. MAT was performed on blood samples taken from each patient on the 7th day of fever. Leptospirosis case definition was evaluated in regard to sensitivity, specificity and predictive values, using a MAT titre >or= 1:800 for confirming leptospirosis. A total of 123 patients were initially recruited of which 73 had clinical features compatible with the surveillance case definition. Out of the 73 only 57 had a positive MAT result (true positives) leaving 16 as false positives. Out of the 50 who didn't have clinical features compatible with the case definition 45 had a negative MAT as well (true negatives), therefore 5 were false negatives. Total number of MAT positives was 62 out of 123. According to these results the test sensitivity was 91.94%, specificity 73.77%, positive predictive value and negative predictive values were 78.08% and 90% respectively. Diagnostic accuracy of the test was 82.93%. This study confirms that the surveillance case definition has a very high sensitivity and negative predictive value with an average specificity in diagnosing leptospirosis, based on a MAT titre of >or= 1: 800.

  9. Performance of an HRP-2 Rapid Diagnostic Test in Nigerian Children Less Than 5 Years of Age

    PubMed Central

    Ajumobi, Olufemi; Sabitu, Kabir; Nguku, Patrick; Kwaga, Jacob; Ntadom, Godwin; Gitta, Sheba; Elizeus, Rutebemberwa; Oyibo, Wellington; Nsubuga, Peter; Maire, Mark; Poggensee, Gabriele

    2015-01-01

    The diagnostic performance of histidine-rich protein 2 (HRP-2)–based malaria rapid diagnostic test (RDT) was evaluated in a mesoendemic area for malaria, Kaduna, Nigeria. We compared RDT results with expert microscopy results of blood samples from 295 febrile children under 5 years. Overall, 11.9% (35/295) tested positive with RDT compared with 10.5% (31/295) by microscopy: sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 100%, 98.5%, 88.6%, and 100%, respectively. The RDT sensitivity was not affected by transmission season, parasite density, and age. Specificity and positive PV decreased slightly during the high-transmission season (97.5% and 83.3%). The RDT test positivity rates in the low- and high-transmission seasons were 9.4% and 13.5%, respectively. Overall, the test performance of this RDT was satisfactory. The findings of a low proportion of RDT false positives, no invalid and no false-negative results should validate the performance of RDTs in this context. PMID:25711608

  10. Bayesian analysis of two diagnostic methods for paediatric ringworm infections in a teaching hospital.

    PubMed

    Rath, S; Panda, M; Sahu, M C; Padhy, R N

    2015-09-01

    Quantitatively, conventional methods of diagnosis of tinea capitis or paediatric ringworm, microscopic and culture tests were evaluated with Bayes rule. This analysis would help in quantifying the pervasive errors in each diagnostic method, particularly the microscopic method, as a long-term treatment would be involved to eradicate the infection by the use of a particular antifungal chemotherapy. Secondly, the analysis of clinical data would help in obtaining digitally the fallible standard of the microscopic test method, as the culture test method is taken as gold standard. Test results of 51 paediatric patients were of 4 categories: 21 samples were true positive (both tests positive), and 13 were true negative; the rest samples comprised both 14 false positive (microscopic test positivity with culture test negativity) and 3 false negative (microscopic test negativity with culture test positivity) samples. The prevalence of tinea infection was 47.01% in the population of 51 children. The microscopic test of a sample was efficient by 87.5%, in arriving at a positive result on diagnosis, when its culture test was positive; and, this test was efficient by 76.4%, in arriving at a negative result, when its culture test was negative. But, the post-test probability value of a sample with both microscopic and culture tests would be correct in distinguishing a sample from a sick or a healthy child with a chance of 71.5%. However, since the sensitivity of the analysis is 87.5%, the microscopic test positivity would be easier to detect in the presence of infection. In conclusion, it could be stated that Trychophyton rubrum was the most prevalent species; sensitivity and specificity of treating the infection, by antifungal therapy before ascertaining by the culture method remain as 0.8751 and 0.7642, respectively. A correct/coveted diagnostic method of fungal infection would be could be achieved by modern molecular methods (matrix-assisted laser desorption ionisation-time of flight mass spectrometry or fluorescence in situ hybridization or enzyme-linked immunosorbent assay [ELISA] or restriction fragment length polymorphism or DNA/RNA probes of known fungal taxa) in advanced laboratories. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  11. Kinetics of a Tuberculosis-Specific Gamma Interferon Release Assay in Military Personnel with a Positive Tuberculin Skin Test▿ †

    PubMed Central

    van Brummelen, Sigrid E.; Bauwens, Anja M.; Schlösser, Noël J.; Arend, Sandra M.

    2010-01-01

    Treatment of latent Mycobacterium tuberculosis infection on the basis of the tuberculin skin test (TST) result is inaccurate due to the false-positive TST results that occur after Mycobacterium bovis BCG vaccination or exposure to nontuberculous mycobacteria (NTM). Gamma interferon release assays (IGRAs) are based on M. tuberculosis-specific antigens. In a previous study among BCG-naïve military employees, a positive TST result after deployment was mostly associated with a negative IGRA result, suggesting exposure to NTM. Data regarding the kinetics of IGRAs are limited and controversial. The present study aimed to reassess the rate of false-positive TST results and to evaluate the kinetics of the Quantiferon TB Gold In-Tube assay (QFT-Git) in military personnel with a positive TST result. QFT-Git was performed at the time of inclusion in the study and was repeated after 2, 6, 12, and 18 or 24 months. Of 192 participants, 17 were recruits and 175 were screened after deployment (n = 169) or because of travel or health care work. Baseline positive QFT-Git results were observed in 7/17 (41.2%) and 12/174 (6.9%) participants, respectively. During follow-up, a negative QFT-Git result remained negative in 163/165 (98.8%) participants. Of 18 subjects with an initial positive QFT-Git result, reversion to a negative result occurred in 1/6 (16%) recruits, whereas it occurred in 8/12 (66%) subjects after deployment or with other risk factors (P = 0.046). The quantitative result was significantly lower in subjects with reversion than in those with consistent positive results (P = 0.017). This study confirmed a low rate of positive QFT-Git results among military personnel with a positive TST result after deployment, supporting the hypothesis of exposure to NTM. Reversion of the majority of initially low-positive QFT-Git results indicates that QFT-Git may be useful for the diagnosis of later reinfections. PMID:20375241

  12. Quality of malaria diagnosis and molecular confirmation of Plasmodium ovale curtisi in a rural area of the southeastern region of Ethiopia.

    PubMed

    Díaz, Pedro Berzosa; Lozano, Patricia Mula; Rincón, Jose Manuel Ramos; García, Luz; Reyes, Francisco; Llanes, Agustín Benito

    2015-09-18

    Approximately 50 million people (60 %) live in malaria risk areas in Ethiopia, at altitudes below 2000 m. According to official data, 60-70 % of malaria cases are due to Plasmodium falciparum, and 40-30 % by Plasmodium vivax. The species Plasmodium ovale was detected in 2013 in the northwest of the country, being the first report of the presence of this species in Ethiopia since the 60 s. The aim of this study was to assess the diagnosis by microscopy and PCR, and demonstrate the presence of other Plasmodium species in the country. The survey was conducted in Bulbula, situated in the Rift Valley (West Arsi Province, Oromia Region). From December 2010 to October 2011, 3060 samples were collected from patients with symptoms of malaria; the diagnosis of malaria was done by microscopy and confirmation by PCR. 736 samples were positive for malaria by microscopy. After removing the 260 samples (109 positives and 151 negatives) for which it was not possible to do PCR, there were a total of 2800 samples, 1209 are used for its confirmation by PCR and quality control (627 are positives and 582 negatives by microscopy). From the 627 positive samples, 604 were confirmed as positive by PCR, 23 false positives were detected, and the group of 582 negative samples, 184 were positive by PCR (false negatives), which added to the previous positive samples is a total of 788, positive samples for some species of Plasmodium sp. 13.3 % more positives were detected with the PCR than the microscopy. Importantly, 23 samples were detected by PCR as P. ovale, after the sequencing of these samples was determined as P. ovale curtisi. The PCR detected more positive samples than the microscopy; in addition, P. ovale and P. ovale/P. vivax were detected that had not been detected by microscopy, which can affect in the infection control.

  13. Experience with a tuberculosis antigen test in Rhodesia.

    PubMed

    Cookson, J B; Cruickshank, J G; Ellis, B P

    1977-10-01

    Experience with a new serological method for the diagnosis of tuberculosis is reported in a predominantly black population. We have found that in only 69% of 167 patients was there agreement between serology and the presence or absence of tuberculosis. Both false positive and false negative results were common. Of 47 healthy controls, 80% were positive. These results are less satisfactory than previous studies but differences in the reading of the results seems an unlikely explanation. Differences in the populations studied may be an important factor.

  14. False-Positive Cases of Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomographic Scans in Metastasis of Esophageal Cancer

    PubMed Central

    Yamatsuji, Tomoki; Ishida, Naomasa; Takaoka, Munenori; Hayashi, Jiro; Yoshida, Kazuhiro; Shigemitsu, Kaori; Urakami, Atsushi; Haisa, Minoru; Naomoto, Yoshio

    2017-01-01

    Of 129 esophagectomies at our institute from June 2010 to March 2015, we experienced three preoperative positron emission tomography-computed tomographic (PET/CT) false positives. Bone metastasis was originally suspected in 2 cases, but they were later found to be bone metastasis negative after a preoperative bone biopsy and clinical course observation. The other cases suspected of mediastinal lymph node metastasis were diagnosed as inflammatory lymphadenopathy by a pathological examination of the removed lymph nodes. Conducting a PET/CT is useful when diagnosing esophageal cancer metastasis, but we need to be aware of the possibility of false positives. Therapeutic decisions should be made based on appropriate and accurate diagnoses, with pathological diagnosis actively introduced if necessary. PMID:28469502

  15. Causes of false-negative for high-grade urothelial carcinoma in urine cytology.

    PubMed

    Lee, Paul J; Owens, Christopher L; Lithgow, Marie Y; Jiang, Zhong; Fischer, Andrew H

    2016-12-01

    The Paris System for classifying urine cytology emphasizes identification of high-grade urothelial carcinoma (HGUC). The causes of false-negative urine cytologies (UC) within this system are not well described. We identified 660 cases between 2005 and 2013 with both UC and subsequent cystoscopic biopsies. UC were classified as either Negative for HGUC or "Abnormal" ("Atypical", "Suspicious", and "Malignant"). Apparent false-negative cases were reviewed in a nonblinded fashion by two cytopathologists and two subspecialized genitourinary pathologists. A total of 199 of the 660 cases (30%) were histologically diagnosed as HGUC. The UC were "Abnormal" in 170/199 cases (sensitivity/specificity of 86%/71%). Twenty four apparent false negative cases were available for retrospective review. Five of 24 (21%) cystoscopic biopsies were found not to be HGUC on review (one false positive and four low-grade urothelial carcinoma (LGUC on review). Of the remaining 19 UC, 7 (29%) cytology samples were found to be truly negative on review, 11 (46%) were found to be Atypical, and 1 (4%) suspicious. Of the 12 UC that were at least "Atypical" with histologic HGUC on review: six misses (half) were attributed to obscuring inflammation/blood, four to poor preservation, eight to paucity of abnormal cells, and 1 case to interpretive error; many cases demonstrated overlapping reasons. About one fifth of apparent false negative diagnoses for HGUC can be because of overdiagnosis of HGUC by surgical pathologists. If poor preservation or obscured samples are called nondiagnostic, the sensitivity/specificity of UC for HGUC can be as high as 94%/71%. Diagn. Cytopathol. 2016;44:994-999. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  16. Mood-congruent memory in depression - the influence of personal relevance and emotional context.

    PubMed

    Wittekind, Charlotte E; Terfehr, Kirsten; Otte, Christian; Jelinek, Lena; Hinkelmann, Kim; Moritz, Steffen

    2014-03-30

    The investigation of veridical mood-congruent memory (MCM) in major depressive disorder (MDD) has been subject of many studies, whereas mood-congruent false memory has received comparatively little attention. The present study examined the influence of valence, personal relevance and the valence of the context of the learning material on true and false MCM in 20 inpatients with MDD and 20 healthy controls. Sixty positive, negative, neutral or personally relevant nouns were either combined with a positive, negative or neutral adjective. Word pairs were presented to participants in a learning trial. In a recognition task, participants had to identify the previously studied word pairs. A MCM effect could not be found for hits. However, in exploratory analyses, word pairs containing personally relevant nouns were more rated towards old by the patient relative to the control group. Furthermore, depressed patients tended to rate items more towards old than controls when the words were presented in a negative new context. Results are in line with previous findings in depression research emphasizing the role of mood-congruent false memories for mood disorders. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Enhanced HTS hit selection via a local hit rate analysis.

    PubMed

    Posner, Bruce A; Xi, Hualin; Mills, James E J

    2009-10-01

    The postprocessing of high-throughput screening (HTS) results is complicated by the occurrence of false positives (inactive compounds misidentified as active by the primary screen) and false negatives (active compounds misidentified as inactive by the primary screen). An activity cutoff is frequently used to select "active" compounds from HTS data; however, this approach is insensitive to both false positives and false negatives. An alternative method that can minimize the occurrence of these artifacts will increase the efficiency of hit selection and therefore lead discovery. In this work, rather than merely using the activity of a given compound, we look at the presence and absence of activity among all compounds in its "chemical space neighborhood" to give a degree of confidence in its activity. We demonstrate that this local hit rate (LHR) analysis method outperforms hit selection based on ranking by primary screen activity values across ten diverse high throughput screens, spanning both cell-based and biochemical assay formats of varying biology and robustness. On average, the local hit rate analysis method was approximately 2.3-fold and approximately 1.3-fold more effective in identifying active compounds and active chemical series, respectively, than selection based on primary activity alone. Moreover, when applied to finding false negatives, this method was 2.3-fold better than ranking by primary activity alone. In most cases, novel hit series were identified that would have otherwise been missed. Additional uses of and observations regarding this HTS analysis approach are also discussed.

  18. False-positive cerebrospinal fluid cryptococcus antigen in Libman-Sacks endocarditis.

    PubMed

    Isseh, Iyad N; Bourgi, Kassem; Nakhle, Asaad; Ali, Mahmoud; Zervos, Marcus J

    2016-12-01

    Cryptococcus meningoencephalitis is a serious opportunistic infection associated with high morbidity and mortality in immunocompromised hosts, particularly patients with advanced AIDS disease. The diagnosis is established through cerebrospinal fluid (CSF) cryptococcus antigen detection and cultures. Cryptococcus antigen testing is usually the initial test of choice due its high sensitivity and specificity along with the quick availability of the results. We hereby report a case of a false-positive CSF cryptococcus antigen assay in a patient with systemic lupus erythematosus presenting with acute confusion. While initial CSF evaluation revealed a positive cryptococcus antigen assay, the patient's symptoms were inconsistent with cryptococcus meningoencephalitis. A repeat CSF evaluation, done 3 days later, revealed a negative CSF cryptococcus antigen assay. Given the patient's active lupus disease and the elevated antinuclear antibody titers, we believe that the initial positive result was a false positive caused by interference from autoantibodies.

  19. TargetMiner: microRNA target prediction with systematic identification of tissue-specific negative examples.

    PubMed

    Bandyopadhyay, Sanghamitra; Mitra, Ramkrishna

    2009-10-15

    Prediction of microRNA (miRNA) target mRNAs using machine learning approaches is an important area of research. However, most of the methods suffer from either high false positive or false negative rates. One reason for this is the marked deficiency of negative examples or miRNA non-target pairs. Systematic identification of non-target mRNAs is still not addressed properly, and therefore, current machine learning approaches are compelled to rely on artificially generated negative examples for training. In this article, we have identified approximately 300 tissue-specific negative examples using a novel approach that involves expression profiling of both miRNAs and mRNAs, miRNA-mRNA structural interactions and seed-site conservation. The newly generated negative examples are validated with pSILAC dataset, which elucidate the fact that the identified non-targets are indeed non-targets.These high-throughput tissue-specific negative examples and a set of experimentally verified positive examples are then used to build a system called TargetMiner, a support vector machine (SVM)-based classifier. In addition to assessing the prediction accuracy on cross-validation experiments, TargetMiner has been validated with a completely independent experimental test dataset. Our method outperforms 10 existing target prediction algorithms and provides a good balance between sensitivity and specificity that is not reflected in the existing methods. We achieve a significantly higher sensitivity and specificity of 69% and 67.8% based on a pool of 90 feature set and 76.5% and 66.1% using a set of 30 selected feature set on the completely independent test dataset. In order to establish the effectiveness of the systematically generated negative examples, the SVM is trained using a different set of negative data generated using the method in Yousef et al. A significantly higher false positive rate (70.6%) is observed when tested on the independent set, while all other factors are kept the same. Again, when an existing method (NBmiRTar) is executed with the our proposed negative data, we observe an improvement in its performance. These clearly establish the effectiveness of the proposed approach of selecting the negative examples systematically. TargetMiner is now available as an online tool at www.isical.ac.in/ approximately bioinfo_miu

  20. An investigation into false-negative transthoracic fine needle aspiration and core biopsy specimens.

    PubMed

    Minot, Douglas M; Gilman, Elizabeth A; Aubry, Marie-Christine; Voss, Jesse S; Van Epps, Sarah G; Tuve, Delores J; Sciallis, Andrew P; Henry, Michael R; Salomao, Diva R; Lee, Peter; Carlson, Stephanie K; Clayton, Amy C

    2014-12-01

    Transthoracic fine needle aspiration (TFNA)/core needle biopsy (CNB) under computed tomography (CT) guidance has proved useful in the assessment of pulmonary nodules. We sought to determine the TFNA false-negative (FN) rate at our institution and identify potential causes of FN diagnoses. Medical records were reviewed from 1,043 consecutive patients who underwent CT-guided TFNA with or without CNB of lung nodules over a 5-year time period (2003-2007). Thirty-seven FN cases of "negative" TFNA/CNB with malignant outcome were identified with 36 cases available for review, of which 35 had a corresponding CNB. Cases were reviewed independently (blinded to original diagnosis) by three pathologists with 15 age- and sex-matched positive and negative controls. Diagnosis (i.e., nondiagnostic, negative or positive for malignancy, atypical or suspicious) and qualitative assessments were recorded. Consensus diagnosis was suspicious or positive in 10 (28%) of 36 TFNA cases and suspicious in 1 (3%) of 35 CNB cases, indicating potential interpretive errors. Of the 11 interpretive errors (including both suspicious and positive cases), 8 were adenocarcinomas, 1 squamous cell carcinoma, 1 metastatic renal cell carcinoma, and 1 lymphoma. The remaining 25 FN cases (69.4%) were considered sampling errors and consisted of 7 adenocarcinomas, 3 nonsmall cell carcinomas, 3 lymphomas, 2 squamous cell carcinomas, and 2 renal cell carcinomas. Interpretive and sampling error cases were more likely to abut the pleura, while histopathologically, they tended to be necrotic and air-dried. The overall FN rate in this patient cohort is 3.5% (1.1% interpretive and 2.4% sampling errors). © 2014 Wiley Periodicals, Inc.

  1. Dogs cannot bark: event-related brain responses to true and false negated statements as indicators of higher-order conscious processing.

    PubMed

    Herbert, Cornelia; Kübler, Andrea

    2011-01-01

    The present study investigated event-related brain potentials elicited by true and false negated statements to evaluate if discrimination of the truth value of negated information relies on conscious processing and requires higher-order cognitive processing in healthy subjects across different levels of stimulus complexity. The stimulus material consisted of true and false negated sentences (sentence level) and prime-target expressions (word level). Stimuli were presented acoustically and no overt behavioral response of the participants was required. Event-related brain potentials to target words preceded by true and false negated expressions were analyzed both within group and at the single subject level. Across the different processing conditions (word pairs and sentences), target words elicited a frontal negativity and a late positivity in the time window from 600-1000 msec post target word onset. Amplitudes of both brain potentials varied as a function of the truth value of the negated expressions. Results were confirmed at the single-subject level. In sum, our results support recent suggestions according to which evaluation of the truth value of a negated expression is a time- and cognitively demanding process that cannot be solved automatically, and thus requires conscious processing. Our paradigm provides insight into higher-order processing related to language comprehension and reasoning in healthy subjects. Future studies are needed to evaluate if our paradigm also proves sensitive for the detection of consciousness in non-responsive patients.

  2. False Memory in Adults With ADHD: A Comparison Between Subtypes and Normal Controls.

    PubMed

    Soliman, Abdrabo Moghazy; Elfar, Rania Mohamed

    2017-10-01

    To examine the performance on the Deese-Roediger-McDermott task of adults divided into ADHD subtypes and compares their performance to that of healthy controls to examine whether adults with ADHD are more susceptible to the production of false memories under experimental conditions. A total of 128 adults with ADHD (50% females), classified into three Diagnostic and Statistical Manual of Mental Disorders (4th ed.; DSM-IV-TR) subtypes, were compared with 48 controls. The results indicated that the ADHD participants recalled and recognized fewer studied words than the controls, the ADHD groups produced more false memories than the control group, no differences in either the false positives or the false negatives. The ADHD-combined (ADHD-CT) group recognized significantly more critical words than the control, ADHD-predominantly inattentive (ADHD-IA), and ADHD-predominantly hyperactive-impulsive (ADHD-HI) groups. The ADHD groups recalled and recognized more false positives, were more confident in their false responses, and displayed more knowledge corruption than the controls. The ADHD-CT group recalled and recognized more false positives than the other ADHD groups. The adults with ADHD have more false memories than the controls and that false memory formation varied with the ADHD subtypes.

  3. Establishing a sample-to cut-off ratio for lab-diagnosis of hepatitis C virus in Indian context.

    PubMed

    Tiwari, Aseem K; Pandey, Prashant K; Negi, Avinash; Bagga, Ruchika; Shanker, Ajay; Baveja, Usha; Vimarsh, Raina; Bhargava, Richa; Dara, Ravi C; Rawat, Ganesh

    2015-01-01

    Lab-diagnosis of hepatitis C virus (HCV) is based on detecting specific antibodies by enzyme immuno-assay (EIA) or chemiluminescence immuno-assay (CIA). Center for Disease Control reported that signal-to-cut-off (s/co) ratios in anti-HCV antibody tests like EIA/CIA can be used to predict the probable result of supplemental test; above a certain s/co value it is most likely to be true-HCV positive result and below that certain s/co it is most likely to be false-positive result. A prospective study was undertaken in patients in tertiary care setting for establishing this "certain" s/co value. The study was carried out in consecutive patients requiring HCV testing for screening/diagnosis and medical management. These samples were tested for anti-HCV on CIA (VITROS(®) Anti-HCV assay, Ortho-Clinical Diagnostics, New Jersey) for calculating s/co value. The supplemental nucleic acid test used was polymerase chain reaction (PCR) (Abbott). PCR test results were used to define true negatives, false negatives, true positives, and false positives. Performance of different putative s/co ratios versus PCR was measured using sensitivity, specificity, positive predictive value and negative predictive value and most appropriate s/co was considered on basis of highest specificity at sensitivity of at least 95%. An s/co ratio of ≥6 worked out to be over 95% sensitive and almost 92% specific in 438 consecutive patient samples tested. The s/co ratio of six can be used for lab-diagnosis of HCV infection; those with s/co higher than six can be diagnosed to have HCV infection without any need for supplemental assays.

  4. Risk factors for false-negative T-SPOT.TB assay results in patients with pulmonary and extra-pulmonary TB.

    PubMed

    Pan, Liping; Jia, Hongyan; Liu, Fei; Sun, Huishan; Gao, Mengqiu; Du, Fengjiao; Xing, Aiying; Du, Boping; Sun, Qi; Wei, Rongrong; Gu, Shuxiang; Zhang, Zongde

    2015-04-01

    To investigate the risk factors for false-negative T-SPOT.TB results in patients with pulmonary TB (PTB) and extra-pulmonary TB (EPTB). Patients with suspected TB who underwent valid T-SPOT.TB tests were prospectively enrolled at Beijing Chest Hospital between November 2012 and November 2013. Basic characters and clinical laboratory findings were compared between true-positive and false-negative T-SPOT.TB groups. Of 1928 suspected TB patients, 774 (530 PTB and 244 EPTB) microbiologically/histopathogenically-confirmed patients (636 culture-confirmed) were analyzed. Forty-six PTB patients (8.7%) and 32 EPTB patients (13.1%) had negative T-SPOT.TB results. Multivariate analysis showed that increased age [odds radio (OR) 2.26, 95% confidence interval (CI) 1.11-4.58], over-weight (BMI ≥ 25 kg/m(2), OR 2.43, 95% CI 1.05-5.63), and a longer period of illness before hospitalization (>6 months, OR 2.46, 95% CI 1.24-4.92) were independent risk factors for false-negative T-SPOT.TB results in PTB patients. In EPTB patients, increased age (OR 2.42, 95% CI 1.09-5.35) also showed an independent association with false-negative T-SPOT.TB results. Careful interpretation of negative T-SPOT.TB results is necessary in older patients with suspected PTB or EPTB, and in PTB patients who are over-weight or have had longer periods of illness before hospitalization. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  5. Accuracy of blood culture for early diagnosis of mediastinitis in febrile patients after cardiac surgery.

    PubMed

    San Juan, R; Aguado, J M; López, M J; Lumbreras, C; Enriquez, F; Sanz, F; Chaves, F; López-Medrano, F; Lizasoain, M; Rufilanchas, J J

    2005-03-01

    Postsurgical mediastinitis (PSM) remains a major cause of morbidity and mortality in patients undergoing cardiac surgery procedures. Although prompt diagnosis is crucial in these patients, neither clinical data nor imaging techniques have shown enough sensitivity or specificity for early diagnosis of PSM. The aim of the present study was to assess the validity of blood cultures as a diagnostic test for the early detection of PSM in patients who become febrile after cardiac surgery procedures. During a 4-year period (1999-2002), patients who developed fever (>37.8 degrees C) in the first 60 days after a cardiac surgery procedure were evaluated. Blood cultures were drawn from these patients. PSM was defined as deep infection involving retrosternal tissue and/or the sternal bone directly observed by the surgeon and confirmed microbiologically. Three criteria for positivity of blood cultures were applied: bacteremia, staphylococcal bacteremia, or Staphylococcus aureus bacteremia. For purposes of the analysis, a positive blood culture in patients with PSM was considered a true-positive test and a negative blood culture a false-negative test. Otherwise, in febrile patients without PSM in the postsurgery period, a positive blood culture was considered a false-positive test and a negative blood culture a true-negative test. Blood cultures were drawn from 266 febrile patients in the postsurgery period. PSM occurred in 38 patients (26 cases due to S. aureus, 8 to Staphylococcus epidermidis, 3 to gram-negative enteric bacteria, and one to Pseudomonas aeruginosa). Within the 60-day postsurgical period, blood culture as a diagnostic test was most accurate in patients with S. aureus bacteremia, providing 68% sensitivity, 98% specificity, a positive predictive value of 87%, and a negative predictive value of 95%. If the analysis was limited to the period during which patients are at maximum risk for PSM (day 7-20), the values in patients with S. aureus bacteremia were as follows: 73% sensitivity, 98% specificity, 90% positive predictive value, and 93% negative predictive value. Blood culture is an accurate test for the early diagnosis of PSM in febrile patients after cardiac surgery, particularly in institutions where S. aureus is prevalent in this context. A negative blood culture practically excludes PSM and, during the period of maximum risk for PSM, the presence of S. aureus bacteremia should compel early surgical management.

  6. [Prospective performance evaluation of first trimester screenings in Germany for risk calculation through http://www.firsttrimester.net].

    PubMed

    Kleinsorge, F; Smetanay, K; Rom, J; Hörmansdörfer, C; Hörmannsdörfer, C; Scharf, A; Schmidt, P

    2010-12-01

    In 2008, 2 351 first trimester screenings were calculated by a newly developed internet database ( http:// www.firsttrimester.net ) to evaluate the risk for the presence of Down's syndrome. All data were evaluated by the conventional first trimester screening according to Nicolaides (FTS), based on the previous JOY Software, and by the advanced first trimester screening (AFS). After receiving the feedback of the karyotype as well as the rates of the correct positives, correct negatives, false positives, false negatives, the sensitivity and specificity were calculated and compared. Overall 255 cases were investigated which were analysed by both methods. These included 2 cases of Down's syndrome and one case of trisomy 18. The FTS and the AFS had a sensitivity of 100%. The specificity was 88.5% for the FTS and 93.0% for the AFS. As already shown in former studies, the higher specificity of the AFS is a result of a reduction of the false positive rate (28 to 17 cases). As a consequence of the AFS with a detection rate of 100% the rate of further invasive diagnostics in pregnant women is decreased by having 39% fewer positive tested women. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Performance and process in collective and individual memory: the role of social decision schemes and memory bias in collective memory.

    PubMed

    Van Swol, Lyn M

    2008-04-01

    To assess performance and processes in collective and individual memory, participants watched two job candidates on video. Beforehand, half the participants were told they would be tested on their memory of the interviews, and the other half were asked to make a decision to hire one of the candidates. Afterwards, participants completed a recognition memory task in either a group or individual condition. Groups had better recognition memory than individuals. Individuals made more false positives than false negatives and groups exaggerated this. Post-hoc analysis found that groups only exaggerated the tendency towards false positives on items that reflected negatively on the job candidate. There was no significant difference between instruction conditions. When reaching consensus on the recognition task, groups tended to choose the correct answer if at least two members had the correct answer. This method of consensus is discussed as a factor in groups' superior memory performance.

  8. Lymphatic Mapping and Sentinel Lymph Node Biopsy in Women With Squamous Cell Carcinoma of the Vulva: A Gynecologic Oncology Group Study

    PubMed Central

    Levenback, Charles F.; Ali, Shamshad; Coleman, Robert L.; Gold, Michael A.; Fowler, Jeffrey M.; Judson, Patricia L.; Bell, Maria C.; De Geest, Koen; Spirtos, Nick M.; Potkul, Ronald K.; Leitao, Mario M.; Bakkum-Gamez, Jamie N.; Rossi, Emma C.; Lentz, Samuel S.; Burke, James J.; Van Le, Linda; Trimble, Cornelia L.

    2012-01-01

    Purpose To determine the safety of sentinel lymph node biopsy as a replacement for inguinal femoral lymphadenectomy in selected women with vulvar cancer. Patients and Methods Eligible women had squamous cell carcinoma, at least 1-mm invasion, and tumor size ≥ 2 cm and ≤ 6 cm. The primary tumor was limited to the vulva, and there were no groin lymph nodes that were clinically suggestive of cancer. All women underwent intraoperative lymphatic mapping, sentinel lymph node biopsy, and inguinal femoral lymphadenectomy. Histologic ultra staging of the sentinel lymph node was prescribed. Results In all, 452 women underwent the planned procedures, and 418 had at least one sentinel lymph node identified. There were 132 node-positive women, including 11 (8.3%) with false-negative nodes. Twenty-three percent of the true-positive patients were detected by immunohistochemical analysis of the sentinel lymph node. The sensitivity was 91.7% (90% lower confidence bound, 86.7%) and the false-negative predictive value (1-negative predictive value) was 3.7% (90% upper confidence bound, 6.1%). In women with tumor less than 4 cm, the false-negative predictive value was 2.0% (90% upper confidence bound, 4.5%). Conclusion Sentinel lymph node biopsy is a reasonable alternative to inguinal femoral lymphadenectomy in selected women with squamous cell carcinoma of the vulva. PMID:22753905

  9. Cost-effectiveness of WHO-Recommended Algorithms for TB Case Finding at Ethiopian HIV Clinics.

    PubMed

    Adelman, Max W; McFarland, Deborah A; Tsegaye, Mulugeta; Aseffa, Abraham; Kempker, Russell R; Blumberg, Henry M

    2018-01-01

    The World Health Organization (WHO) recommends active tuberculosis (TB) case finding and a rapid molecular diagnostic test (Xpert MTB/RIF) to detect TB among people living with HIV (PLHIV) in high-burden settings. Information on the cost-effectiveness of these recommended strategies is crucial for their implementation. We conducted a model-based cost-effectiveness analysis comparing 2 algorithms for TB screening and diagnosis at Ethiopian HIV clinics: (1) WHO-recommended symptom screen combined with Xpert for PLHIV with a positive symptom screen and (2) current recommended practice algorithm (CRPA; based on symptom screening, smear microscopy, and clinical TB diagnosis). Our primary outcome was US$ per disability-adjusted life-year (DALY) averted. Secondary outcomes were additional true-positive diagnoses, and false-negative and false-positive diagnoses averted. Compared with CRPA, combining a WHO-recommended symptom screen with Xpert was highly cost-effective (incremental cost of $5 per DALY averted). Among a cohort of 15 000 PLHIV with a TB prevalence of 6% (900 TB cases), this algorithm detected 8 more true-positive cases than CRPA, and averted 2045 false-positive and 8 false-negative diagnoses compared with CRPA. The WHO-recommended algorithm was marginally costlier ($240 000) than CRPA ($239 000). In sensitivity analysis, the symptom screen/Xpert algorithm was dominated at low Xpert sensitivity (66%). In this model-based analysis, combining a WHO-recommended symptom screen with Xpert for TB diagnosis among PLHIV was highly cost-effective ($5 per DALY averted) and more sensitive than CRPA in a high-burden, resource-limited setting.

  10. Estimated number of infants detected and missed by critical congenital heart defect screening.

    PubMed

    Ailes, Elizabeth C; Gilboa, Suzanne M; Honein, Margaret A; Oster, Matthew E

    2015-06-01

    In 2011, the US Secretary of Health and Human Services recommended universal screening of newborns for critical congenital heart defects (CCHDs), yet few estimates of the number of infants with CCHDs likely to be detected through universal screening exist. Our objective was to estimate the number of infants with nonsyndromic CCHDs in the United States likely to be detected (true positives) and missed (false negatives) through universal newborn CCHD screening. We developed a simulation model based on estimates of birth prevalence, prenatal diagnosis, late detection, and sensitivity of newborn CCHD screening through pulse oximetry to estimate the number of true-positive and false-negative nonsyndromic cases of the 7 primary and 5 secondary CCHD screening targets identified through screening. We estimated that 875 (95% uncertainty interval [UI]: 705-1060) US infants with nonsyndromic CCHDs, including 470 (95% UI: 360-585) infants with primary CCHD screening targets, will be detected annually through newborn CCHD screening. An additional 880 (UI: 700-1080) false-negative screenings, including 280 (95% UI: 195-385) among primary screening targets, are expected. We estimated that similar numbers of CCHDs would be detected under scenarios comparing "lower" (∼19%) and "higher" (∼41%) than current prenatal detection prevalences. A substantial number of nonsyndromic CCHD cases are likely to be detected through universal CCHD screening; however, an equal number of false-negative screenings, primarily among secondary targets of screening, are likely to occur. Future efforts should document the true impact of CCHD screening in practice. Copyright © 2015 by the American Academy of Pediatrics.

  11. Publication bias and the canonization of false facts.

    PubMed

    Nissen, Silas Boye; Magidson, Tali; Gross, Kevin; Bergstrom, Carl T

    2016-12-20

    Science is facing a "replication crisis" in which many experimental findings cannot be replicated and are likely to be false. Does this imply that many scientific facts are false as well? To find out, we explore the process by which a claim becomes fact. We model the community's confidence in a claim as a Markov process with successive published results shifting the degree of belief. Publication bias in favor of positive findings influences the distribution of published results. We find that unless a sufficient fraction of negative results are published, false claims frequently can become canonized as fact. Data-dredging, p-hacking, and similar behaviors exacerbate the problem. Should negative results become easier to publish as a claim approaches acceptance as a fact, however, true and false claims would be more readily distinguished. To the degree that the model reflects the real world, there may be serious concerns about the validity of purported facts in some disciplines.

  12. Assessing conservation lands for forest birds in an exurban landscape

    Treesearch

    Paige F.B. Ferguson; Michael J. Conroy; Jeffrey Hepinstall-Cymerman

    2017-01-01

    Exurban development is the fastest growing type of land use in the United States and is prominent in the southern Appalachian region. A potential consequence of exurban development is the loss and fragmentation of wildlife habitat. We used a Bayesian model that accounts for false positive and false negative detections to make inferences about how the occupancy...

  13. Diagnostic accuracy of contrast-enhanced spectral mammography in comparison to conventional full-field digital mammography in a population of women with dense breasts.

    PubMed

    Mori, Miki; Akashi-Tanaka, Sadako; Suzuki, Satoko; Daniels, Murasaki Ikeda; Watanabe, Chie; Hirose, Masanori; Nakamura, Seigo

    2017-01-01

    Contrast-enhanced spectral mammography to compare clinical efficacy of contrast-enhanced spectral mammography (CESM) and conventional digital mammography (MMG) with histopathology as gold standard in dense breasts. A total of 143 breasts of 72 women who underwent CESM and MMG between 2011 and 2014 at Showa University Hospital were analyzed. 129 (90.2 %) of 143 breasts revealed dense breasts on MMG. 58 (40.6 %) of 143 breasts were diagnosed with breast cancer at histopathology. The remaining 85 breasts were diagnosed with benign findings after image assessments and/or core needle biopsy. CESM revealed 8 false-negative cases among 58 breast cancer cases (sensitivity 86.2 %) and 5 false-positive cases (specificity 94.1 %). Accuracy was 90.9 %. Conventional MMG was assessed true positive in 31 of 58 breast cancer cases (sensitivity 53.4 %) and false positive in 12 cases (specificity 85.9 %). Accuracy was 72.7 %. Sensitivity (p < 0.001), specificity (p = 0.016) and accuracy (p < 0.001) were significantly higher on CESM compared to MMG. MMG missed malignancy in 27 breasts. Of these, 25 were dense breasts. Of these 25, 20 (80.0 %) breasts were positive on CESM. These findings suggest that CESM offers superior clinical performance compared to MMG. Use of CESM may decrease false negatives especially for women with dense breasts.

  14. The ADRA2B gene in the production of false memories for affective information in healthy female volunteers.

    PubMed

    Fairfield, Beth; Mammarella, Nicola; Di Domenico, Alberto; D'Aurora, Marco; Stuppia, Liborio; Gatta, Valentina

    2017-08-30

    False memories are common memory distortions in everyday life and seem to increase with affectively connoted complex information. In line with recent studies showing a significant interaction between the noradrenergic system and emotional memory, we investigated whether healthy volunteer carriers of the deletion variant of the ADRA2B gene that codes for the α2b-adrenergic receptor are more prone to false memories than non-carriers. In this study, we collected genotype data from 212 healthy female volunteers; 91 ADRA2B carriers and 121 non-carriers. To assess gene effects on false memories for affective information, factorial mixed model analysis of variances (ANOVAs) were conducted with genotype as the between-subjects factor and type of memory error as the within-subjects factor. We found that although carriers and non-carriers made comparable numbers of false memory errors, they showed differences in the direction of valence biases, especially for inferential causal errors. Specifically, carriers produced fewer causal false memory errors for scripts with a negative outcome, whereas non-carriers showed a more general emotional effect and made fewer causal errors with both positive and negative outcomes. These findings suggest that putatively higher levels of noradrenaline in deletion carriers may enhance short-term consolidation of negative information and lead to fewer memory distortions when facing negative events. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Breast cancer mammographic diagnosis performance in a public health institution: a retrospective cohort study.

    PubMed

    Mello, Juliana M R B; Bittelbrunn, Fernando P; Rockenbach, Marcio A B C; May, Guilherme G; Vedolin, Leonardo M; Kruger, Marilia S; Soldatelli, Matheus D; Zwetsch, Guilherme; de Miranda, Gabriel T F; Teixeira, Saone I P; Arruda, Bruna S

    2017-12-01

    To evaluate the quality assurance of mammography results at a reference institution for the diagnosis and treatment of breast cancer in southern Brazil, based on the BIRADS (Breast Imaging Reporting and Data System) 5th edition recommendations for auditing purposes. Retrospective cohort and cross-sectional study with 4502 patients (9668 mammographies)) who underwent at least one or both breast mammographies throughout 2013 at a regional public hospital, linked to a federal public university. The results were followed until 31 December 2014, including true positives (TPs), true negatives (TNs), false positives (FPs), false negatives (FNs), positive predictive values (PPVs), negative predictive value (NPV), sensitivity and specificity, with a confidence interval of 95%. The study showed high quality assurance, particularly regarding sensitivity (90.22%) and specificity (92.31%). The overall positive predictive value (PPV) was 65.35%, and the negative predictive value (NPV) was 98.32%. The abnormal interpretation rate (recall rate) was 12.26%. The results are appropriate when compared to the values proposed by the BIRADS 5th edition. Additionally, the study provided self-reflection considering our radiological practice, which is essential for improvements and collaboration regarding breast cancer detection. It may stimulate better radiological practice performance and continuing education, despite possible infrastructure and facility limitations. • Accurate quality performance rates are possible despite financial and governmental limitations. • Low-income institutions should develop standardised teamwork to improve radiological practice. • Regular mammography audits may help to increase the quality of public health systems.

  16. Screening for cervical cancer among HIV-positive and HIV-negative women in Cameroon using simultaneous co-testing with careHPV DNA testing and visual inspection enhanced by digital cervicography: Findings of initial screening and one-year follow-up.

    PubMed

    Cholli, Preetam; Bradford, Leslie; Manga, Simon; Nulah, Kathleen; Kiyang, Edith; Manjuh, Florence; DeGregorio, Geneva; Ogembo, Rebecca K; Orock, Enow; Liu, Yuxin; Wamai, Richard G; Sheldon, Lisa Kennedy; Gona, Philimon N; Sando, Zacharie; Welty, Thomas; Welty, Edith; Ogembo, Javier Gordon

    2018-01-01

    The World Health Organization (WHO)'s cervical cancer screening guidelines for limited-resource settings recommend sequential screening followed by same-day treatment under a "screen-and-treat" approach. We aimed to (1) assess feasibility and clinical outcomes of screening HIV-positive and HIV-negative Cameroonian women by pairing visual inspection with acetic acid and Lugol's iodine enhanced by digital cervicography (VIA/VILI-DC) with careHPV, a high-risk human papillomavirus (HR-HPV) nucleic acid test designed for low-resource settings; and (2) determine persistence of HR-HPV infection after one-year follow-up to inform optimal screening, treatment, and follow-up algorithms. We co-tested 913 previously unscreened women aged ≥30years and applied WHO-recommended treatment for all VIA/VILI-DC-positive women. Baseline prevalence of HR-HPV and HIV were 24% and 42%, respectively. On initial screen, 44 (5%) women were VIA/VILI-DC-positive, of whom 22 had HR-HPV infection, indicating 50% of women screened false-positive and would have been triaged for unnecessary same-day treatment. VIA/VILI-DC-positive women with HIV infection were three times more likely to be HR-HPV-positive than HIV-negative women (65% vs. 20%). All women positive for either VIA/VILI-DC or HR-HPV (n=245) were invited for repeat co-testing after one year, of which 136 (56%) returned for follow-up. Of 122 women who were HR-HPV-positive on initial screen, 60 (49%) re-tested negative, of whom 6 had received treatment after initial screen, indicating that 44% of initially HR-HPV-positive women spontaneously cleared infection after one year without treatment. Women with HIV were more likely to remain HR-HPV-positive on follow-up than HIV-negative women (61% vs. 22%, p<0.001). Treatment was offered to all VIA/VILI-DC positive women on initial screen, and to all women screening VIA/VILI-DC or HR-HPV positive on follow-up. We found careHPV co-testing with VIA/VILI-DC to be feasible and valuable in identifying false-positives, but careHPV screening-to-result time was too long to inform same-day treatment. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Poor effectiveness of antenatal detection of fetal growth restriction and consequences for obstetric management and neonatal outcomes: a French national study.

    PubMed

    Monier, I; Blondel, B; Ego, A; Kaminiski, M; Goffinet, F; Zeitlin, J

    2015-03-01

    To assess the proportion of small for gestational age (SGA) and normal birthweight infants suspected of fetal growth restriction (FGR) during pregnancy, and to investigate obstetric and neonatal outcomes by suspicion of FGR and SGA status at birth. Population-based study. All French maternity units in 2010. Representative sample of singleton births (n = 14,100). We compared SGA infants with a birthweight of less than the 10th percentile suspected of FGR, defined as mention of FGR in medical charts (true positives), non-SGA infants suspected of FGR (false positives), SGA infants without suspicion of FGR (false negatives) and non-SGA infants without suspicion of FGR (true negatives). Multivariable analyses were adjusted for maternal and neonatal characteristics hypothesised to affect closer surveillance for FGR and our outcomes. Obstetric management (caesarean, provider-initiated preterm and early term delivery) and neonatal outcomes (late fetal death, preterm birth, Apgar score, resuscitation at birth). 21.7% of SGA infants (n = 265) and 2.1% of non-SGA infants (n = 271) were suspected of FGR during pregnancy. Compared with true negatives, provider-initiated preterm deliveries were higher for true and false positives (adjusted risk ratio [aRR], 6.1 [95% CI, 3.8-9.8] and 4.6 [95% CI, 3.2-6.7]), but not for false negatives (aRR, 1.1 [95% CI, 0.6-1.9]). Neonatal outcomes were not better for SGA infants if FGR was suspected. Antenatal suspicion of FGR among SGA infants was low and one-half of infants suspected of FGR were not SGA. The increased risk of provider-initiated delivery observed in non-SGA infants suspected of FGR raises concerns about the iatrogenic consequences of screening. © 2014 The Authors BJOG An International Journal of Obstetrics and Gynaecology published by John Wiley & Sons Ltd on behalf of Royal College of Obstetricians and Gynaecologists.

  18. The reliability of fine-needle aspiration biopsy in terms of malignancy in patients with Hashimoto thyroiditis.

    PubMed

    Kapan, Murat; Onder, Akin; Girgin, Sadullah; Ulger, Burak Veli; Firat, Ugur; Uslukaya, Omer; Oguz, Abdullah

    2015-02-01

    The aim of this study was to analyze the presence of malignancy in patients with Hashimoto's thyroiditis and to investigate the reliability of preoperative fine-needle aspiration biopsy (FNAB). The retrospective study included 44 patients who were operated on for nodular goiter between December 2010 and October 2011. The patients underwent thyroidectomy following a cytologic analysis plus FNAB. Hashimoto's thyroiditis was confirmed on histopathology in all patients. FNAB results were defined as benign in 14 (31.8%), suspicion for malignancy in 17 (38.6%), malignant in 9 (20.5%), and inadequate in 4 (9.1%). Following the thyroidectomy, presence of papillary thyroid carcinoma and follicular variant of papillary thyroid carcinoma were detected in 10 patients (22.7%) and 1 (2.3%) patient, respectively. The FNAB results were interpreted in terms of malignancy, which revealed the sensitivity as 80%; specificity, 40%; false positives, 69.2%; false negatives, 14.3%; positive predictive value, 31.8%; negative predictive value, 85.7%; and diagnostic accuracy, 50%. The coexistence of Hashimoto's thyroiditis with papillary thyroid carcinoma is quite common. The FNAB results for such cases are hard to evaluate, and they are likely to increase the number of false positives.

  19. "Hook-like effect" causes false-negative point-of-care urine pregnancy testing in emergency patients.

    PubMed

    Griffey, Richard T; Trent, Caleb J; Bavolek, Rebecca A; Keeperman, Jacob B; Sampson, Christopher; Poirier, Robert F

    2013-01-01

    Failure to detect pregnancy in the emergency department (ED) can have important consequences. Urine human chorionic gonadotropin (uhCG) point-of-care (POC) assays are valued for rapidly detecting early pregnancy with high sensitivity. However, under certain conditions, POC uhCG tests can fail to detect pregnancy. In investigating a series of late first-trimester false-negative pregnancy tests in our ED, a novel and distinct causative phenomenon was recently elucidated in our institution. We discuss uhCG POC tests, review our false-negative rate, and describe mechanisms for false negatives and potential remedies. The false-negative POC uhCG rate is very low, but in the setting of a large volume of tests, the numbers are worth consideration. In positive uhCG POC tests, free and fixed antibodies bind hCG to form a "sandwich"; hCG is present in several variant forms that change in their concentrations at different stages of pregnancy. When in excess, intact hCG can saturate the antibodies, preventing sandwich formation (hook effect phenomenon). Some assays may include an antibody that does not recognize certain variants present in later stages of pregnancy. When this variant is in excess, it can bind one antibody avidly and the other not at all, resulting in a false-negative test (hook-like phenomenon). In both situations, dilution is key to an accurate test. Manufacturers should consider that uhCG tests are routinely used at many stages of pregnancy. Characterizing uhCG variants recognized by their tests and eliminating lot-to-lot variability may help improve uhCG test performance. Clinicians need to be aware of and familiarize themselves with the limitations of the specific type of uhCG POC tests used in their practice, recognizing that under certain circumstances, false-negative tests can occur. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. [Development and evaluation of a serological protocol of fluorescence polarization for the preliminary study of Brucella spp antibodies in humans].

    PubMed

    Sánchez-Villalobos, Alfredo; Urdaneta-Fernández, Margelys; Rubio-Fuenmayor, Elí; Molero-Saras, Gladys; Luzardo-Charris, Carlos; Corona-Mengual, Carlos

    2011-03-01

    In order to show the development and scope of a serological analysis method based on fluorescence polarization assay (FPA) from a drop of blood obtained by the capillary technique, a Brucella antibody assay was performed on a group of 321 high-risk workers. The results were compared with data from the analysis of blood serum by FPA and a competitive enzyme immunoassay (ELISA-c). The number of concordance was 318 (99.06%), and discordant 3 (0.93%), which were negative in serum by fluorescence polarization (FPAs) and ELISA-c, but positive with capillary FPA (FPAc). The comparative results FPAc were: sensitivity 100%; specificity: 99.05%; positive predictive value 66.67%; negative predictive value 100.0%; false positive rate: 0.95%; false negative rate: 0%; accuracy: 98.0%; odds ratio: 203.00. The youden J for both FPA methods was 0.667. The identification was considered reliable and the correlation of both procedures, FPA and ELISA-c, was no statistically different (P > 0.05%), which allows to highly recommend the study implementation of human brucellosis with capillary blood as a preliminary method.

  1. Paracheck Pf compared with microscopy for diagnosis of Plasmodium falciparum malaria among children in Tanga City, north-eastern Tanzania.

    PubMed

    Kamugisha, M L; Msangeni, H; Beale, E; Malecela, E K; Akida, J; Ishengoma, D R S; Lemnge, M M

    2008-01-01

    Malaria is a major public health problem particularly in rural Sub-Saharan Africa. In most urban areas, malaria transmission intensity is low thus monitoring trends using reliable tools is crucial to provide vital information for future management of the disease. Rapid diagnostic tests (RDT) such as Paracheck Pf are now increasingly adopted for Plasmodium falciparum malaria diagnosis and are advantageous and cost effective alternative to microscopy. This cross sectional survey was carried out during June 2005 to determine the prevalence of malaria in an urban setting and compare microscopy diagnosis versus Paracheck Pf for detecting Plasmodium falciparum. Blood samples from a total of 301 children (< 10 years) attending outpatient clinic at Makorora Health Centre, in Tanga, Tanzania were examined for the presence of malaria. Twenty-nine (9.6%) of the children were positive to malaria by microscopy while 30 (10.0%) were positive by Paracheck test. Three out of 30 positive cases detected by Paracheck were negative by microscopy; thus considered to be false positive results. For the 271 Paracheck Pf negative cases, 2 were positive by microscopy; yielding 2 false negative results. Paracheck Pf sensitivity and specificity were 93.1% and 98.9%, respectively. P. falciparum was the only malarial species observed among the 29 microscopy positive cases. The prevalence of anaemia among the children was 53.16%. These findings indicate a low prevalence of malaria in Tanga City and that Paracheck Pf can be an effective tool for malaria diagnosis.

  2. A PCR method based on 18S rRNA gene for detection of malaria parasite in Balochistan.

    PubMed

    Shahwani, Zubeda; Aleem, Abdul; Ahmed, Nazeer; Mushtaq, Muhammad; Afridi, Sarwat

    2016-12-01

    To establish a polymerase chain reaction method based on 18S ribosomal ribonucleic acid gene for the detection of plasmodium deoxyribonucleic acid in patients suffering from malaria symptoms. This cross-sectional study was conducted from September 2013 to October 2014 in district Quetta of Pakistan's Balochistan province. Blood samples were collected from patients suffering from general symptoms of malaria. A polymerase chain reaction-based technique was applied for the diagnosis of malaria and detection of responsible species in the patients who were suspected to carry the parasite. Performance of this polymerase chain reaction method was compared against the microscopy results. Parasite number was also calculated for microscopy positive samples.All samples after the genomic deoxyribonucleic acid isolation were subjected to polymerase chain reaction amplification and agarose gel electrophoresis. Of the 200 samples, 114(57%) were confirmed as positive and 86(43%) as negative for malaria by microscopy. Polymerase chain reaction identified 124(62%) samples as positive and 76(38%) as negative for malaria. The comparative analysis of both diagnostic methods confirmed 109(54.5%) samples as positive by both techniques. Besides, 5(6.58%) samples were identified as false positive and 15(12.1%) samples as false negative by polymerase chain reaction. Sensitivity, specificity and positive predictive values for polymerase chain reaction in comparison to microscopy were 87.98%, 93.42% and 96%, respectively. Polymerase chain reaction-based methods in malaria diagnosis and species identification were found to be more effective than other techniques.

  3. Optimization and validation of CEDIA drugs of abuse immunoassay tests in serum on Hitachi 912.

    PubMed

    Kirschbaum, Katrin M; Musshoff, Frank; Schmithausen, Ricarda; Stockhausen, Sarah; Madea, Burkhard

    2011-10-10

    Due to sensitive limits of detection of chromatographic methods and low limit values regarding the screening of drugs under the terms of impairment in safe driving (§ 24a StVG, Street Traffic Law in Germany), preliminary immunoassay (IA) tests should be able to detect also low concentrations of legal and illegal drugs in serum in forensic cases. False-negatives should be avoided, the rate of false-positive samples should be low due to cost and time. An optimization of IA cutoff values and a validation of the assay is required for each laboratory. In a retrospective study results for serum samples containing amphetamine, methylenedioxy derivatives, cannabinoids, benzodiazepines, cocaine (metabolites), methadone and opiates obtained with CEDIA drugs of abuse reagents on a Hitachi 912 autoanalyzer were compared with quantitative results of chromatographic methods (gas or liquid chromatography coupled with mass spectrometry (GC/MS or LC/MS)). Firstly sensitivity, specificity, positive and negative predictive values and overall misclassification rates were evaluated by contingency tables and compared to ROC-analyses and Youden-Indices. Secondly ideal cutoffs were statistically calculated on the basis of sensitivity and specificity as decisive statistical criteria with focus on a high sensitivity (low rates of false-negatives), i.e. using the Youden-Index. Immunoassay (IA) and confirmatory results were available for 3014 blood samples. Sensitivity was 90% or more for nearly all analytes: amphetamines (IA cutoff 9.5 ng/ml), methylenedioxy derivatives (IA cutoff 5.5 ng/ml), cannabinoids (IA cutoff 14.5 ng/ml), benzodiazepines (IA cutoff >0 ng/ml). Test of opiates showed a sensitivity of 86% for a IA cutoff value of >0 ng/ml. Values for specificity ranged between 33% (methadone, IA cutoff 10 ng/ml) and 90% (cocaine, IA cutoff 20 ng/ml). Lower cutoff values as recommended by ROC analyses were chosen for most tests to decrease the rate of false-negatives. Analyses enabled the definition of cutoff values with good values for sensitivity. Small rates of false-positives can be accepted in forensic cases. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  4. False memories to emotional stimuli are not equally affected in right- and left-brain-damaged stroke patients.

    PubMed

    Buratto, Luciano Grüdtner; Zimmermann, Nicolle; Ferré, Perrine; Joanette, Yves; Fonseca, Rochele Paz; Stein, Lilian Milnitsky

    2014-10-01

    Previous research has attributed to the right hemisphere (RH) a key role in eliciting false memories to visual emotional stimuli. These results have been explained in terms of two right-hemisphere properties: (i) that emotional stimuli are preferentially processed in the RH and (ii) that visual stimuli are represented more coarsely in the RH. According to this account, false emotional memories are preferentially produced in the RH because emotional stimuli are both more strongly and more diffusely activated during encoding, leaving a memory trace that can be erroneously reactivated by similar but unstudied emotional items at test. If this right-hemisphere hypothesis is correct, then RH damage should result in a reduction in false memories to emotional stimuli relative to left-hemisphere lesions. To investigate this possibility, groups of right-brain-damaged (RBD, N=15), left-brain-damaged (LBD, N=15) and healthy (HC, N=30) participants took part in a recognition memory experiment with emotional (negative and positive) and non-emotional pictures. False memories were operationalized as incorrect responses to unstudied pictures that were similar to studied ones. Both RBD and LBD participants showed similar reductions in false memories for negative pictures relative to controls. For positive pictures, however, false memories were reduced only in RBD patients. The results provide only partial support for the right-hemisphere hypothesis and suggest that inter-hemispheric cooperation models may be necessary to fully account for false emotional memories. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. [Predictive factors of contamination in a blood culture with bacterial growth in an Emergency Department].

    PubMed

    Hernández-Bou, S; Trenchs Sainz de la Maza, V; Esquivel Ojeda, J N; Gené Giralt, A; Luaces Cubells, C

    2015-06-01

    The aim of this study is to identify predictive factors of bacterial contamination in positive blood cultures (BC) collected in an emergency department. A prospective, observational and analytical study was conducted on febrile children aged on to 36 months, who had no risk factors of bacterial infection, and had a BC collected in the Emergency Department between November 2011 and October 2013 in which bacterial growth was detected. The potential BC contamination predicting factors analysed were: maximum temperature, time to positivity, initial Gram stain result, white blood cell count, absolute neutrophil count, band count, and C-reactive protein (CRP). Bacteria grew in 169 BC. Thirty (17.8%) were finally considered true positives and 139 (82.2%) false positives. All potential BC contamination predicting factors analysed, except maximum temperature, showed significant differences between true positives and false positives. CRP value, time to positivity, and initial Gram stain result are the best predictors of false positives in BC. The positive predictive values of a CRP value≤30mg/L, BC time to positivity≥16h, and initial Gram stain suggestive of a contaminant in predicting a FP, are 95.1, 96.9 and 97.5%, respectively. When all 3 conditions are applied, their positive predictive value is 100%. Four (8.3%) patients with a false positive BC and discharged to home were revaluated in the Emergency Department. The majority of BC obtained in the Emergency Department that showed positive were finally considered false positives. Initial Gram stain, time to positivity, and CRP results are valuable diagnostic tests in distinguishing between true positives and false positives in BC. The early detection of false positives will allow minimising their negative consequences. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  6. Specificity of /sup 99m/Tc-pertechnetate in scintigraphic diagnosis of Meckel's diverticulum: review of 100 cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berquist, T.H.; Nolan, N.G.; Stephens, D.H.

    1976-06-01

    Numerous reports in the recent literature have questioned the value of abdominal scanning with pertechnetate in the diagnosis of Meckel's diverticulum. In an attempt to evaluate further the specificity of pertechnetate in this condition, the clinical data and scintigrams of 100 patients with suspected Meckel's diverticulum were reviewed. The scintigram correctly identified Meckel's diverticulum before operation in seven of eight patients. One false-negative study occurred in 33 patients who underwent laparotomy. Conditions suggested as possible causes of false-positive studies (hydronephrosis, arteriovenous malformations, and intussusception) were found to give negative scans. (auth)

  7. Is it time to sound an alarm about false-positive cell-free DNA testing for fetal aneuploidy?

    PubMed

    Mennuti, Michael T; Cherry, Athena M; Morrissette, Jennifer J D; Dugoff, Lorraine

    2013-11-01

    Testing cell-free DNA (cfDNA) in maternal blood samples has been shown to have very high sensitivity for the detection of fetal aneuploidy with very low false-positive results in high-risk patients who undergo invasive prenatal diagnosis. Recent observation in clinical practice of several cases of positive cfDNA tests for trisomy 18 and trisomy 13, which were not confirmed by cytogenetic testing of the pregnancy, may reflect a limitation of the positive predictive value of this quantitative testing, particularly when it is used to detect rare aneuploidies. Analysis of a larger number of false-positive cases is needed to evaluate whether these observations reflect the positive predictive value that should be expected. Infrequently, mechanisms (such as low percentage mosaicism or confined placental mosaicism) might also lead to positive cfDNA testing that is not concordant with standard prenatal cytogenetic diagnosis. The need to explore these and other possible causes of false-positive cfDNA testing is exemplified by 2 of these cases. Additional evaluation of cfDNA testing in clinical practice and a mechanism for the systematic reporting of false-positive and false-negative cases will be important before this test is offered widely to the general population of low-risk obstetric patients. In the meantime, incorporating information about the positive predictive value in pretest counseling and in clinical laboratory reports is recommended. These experiences reinforce the importance of offering invasive testing to confirm cfDNA results before parental decision-making. Copyright © 2013 Mosby, Inc. All rights reserved.

  8. Verification of clinical samples, positive in AMPLICOR Neisseria gonorrhoeae polymerase chain reaction, by 16S rRNA and gyrA compared with culture.

    PubMed

    Airell, Asa; Lindbäck, Emma; Ataker, Ferda; Pörnull, Kirsti Jalakas; Wretlind, Bengt

    2005-06-01

    We compared 956 samples for AMPLICOR Neisseria gonorrhoeae polymerase chain reaction (PCR) (Roche) with species verification using the 16S rRNA gene to verification using gyrA gene. Control was the culture method. The gyrA verification uses pyrosequencing of the quinolone resistance-determining region of gyrA. Of 52 samples with optical density >/=0.2 in PCR, 27 were negative in culture, two samples from pharynx were false negative in culture and four samples from pharynx were false positives in verification with 16S rRNA. Twenty-five samples showed growth of gonococci, 18 of the corresponding PCR samples were verified by both methods; three urine samples were positive only in gyrA ; and one pharynx specimen was positive only in 16S rRNA. Three samples were lost. We conclude that AMPLICOR N. gonorrhoeae PCR with verification in gyrA gene can be considered as a diagnostic tool in populations with low prevalence of gonorrhoea and that pharynx specimens should not be analysed by PCR.

  9. Missed Lesions at CT Colonography: Lessons Learned

    PubMed Central

    Pickhardt, Perry J.

    2017-01-01

    Misinterpretation at CT colonography (CTC) can result in either a colorectal lesion being missed (false negative) or a false-positive diagnosis. This review will largely focus on potential missed lesions – and ways to avoid such misses. The general causes of false-negative interpretation at CTC can be broadly characterized and grouped into discrete categories related to suboptimal study technique, specific lesion characteristics, anatomic location, and imaging artifacts. Overlapping causes further increase the likelihood of missing a clinically relevant lesion. In the end, if the technical factors of bowel preparation, colonic distention, and robust CTC software are adequately addressed on a consistent basis, and the reader is aware of all the potential pitfalls at CTC, important lesions will seldom be missed. PMID:22539045

  10. Evaluation of the LDBIO point of care test for the combined detection of toxoplasmic IgG and IgM.

    PubMed

    Chapey, Emmanuelle; Wallon, Martine; Peyron, François

    2017-01-01

    The toxoplasma ICT IgG-IgM rapid diagnostic test for the simultaneous detection of specific toxoplasmic immunoglobulin (Ig) G and IgM was compared with the Architect fully automated chemiluminescence test. Four hundred sera were included, among which 248 scored negative in Architect. The cassettes were easily read with the naked eye. Diagnostic sensitivity and specificity were 97% and 96%, respectively. The test scored 8 false-positive IgG and yielded negative results in 3 sera displaying unspecific IgM in Architect. The LDBIO appears to be a reliable first line test, although the false-positive results for IgG deserve further investigation. Such an easily performed test could be used advantageously for screening for toxoplasmosis in pregnant women. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Attributions of the "causes" of group performance as an alternative explanation of the relationship between organizational citizenship behavior and organizational performance.

    PubMed

    Bachrach, D G; Bendoly, E; Podsakoff, P M

    2001-12-01

    The purpose of this study was to examine the possibility that feedback regarding team performance may influence team members' reports of organizational citizenship behaviors. Ninety-five teams of business students (N = 412) participated in a labor-scheduling simulation over a local area network. Teams were provided with false negative, false positive, or neutral feedback regarding their performance. Results support the hypothesis that the perception of 2 forms of organizational citizenship behavior (helping behavior and civic virtue) in work groups may, in part. be a function of the nature of the performance feedback that group members receive. However, negative feedback appears to play a more critical role than positive feedback in this attributional process. Possible reasons for these findings, as well as their implications, are discussed.

  12. Comment on Hall et al. (2017), "How to Choose Between Measures of Tinnitus Loudness for Clinical Research? A Report on the Reliability and Validity of an Investigator-Administered Test and a Patient-Reported Measure Using Baseline Data Collected in a Phase IIa Drug Trial".

    PubMed

    Sabour, Siamak

    2018-03-08

    The purpose of this letter, in response to Hall, Mehta, and Fackrell (2017), is to provide important knowledge about methodology and statistical issues in assessing the reliability and validity of an audiologist-administered tinnitus loudness matching test and a patient-reported tinnitus loudness rating. The author uses reference textbooks and published articles regarding scientific assessment of the validity and reliability of a clinical test to discuss the statistical test and the methodological approach in assessing validity and reliability in clinical research. Depending on the type of the variable (qualitative or quantitative), well-known statistical tests can be applied to assess reliability and validity. The qualitative variables of sensitivity, specificity, positive predictive value, negative predictive value, false positive and false negative rates, likelihood ratio positive and likelihood ratio negative, as well as odds ratio (i.e., ratio of true to false results), are the most appropriate estimates to evaluate validity of a test compared to a gold standard. In the case of quantitative variables, depending on distribution of the variable, Pearson r or Spearman rho can be applied. Diagnostic accuracy (validity) and diagnostic precision (reliability or agreement) are two completely different methodological issues. Depending on the type of the variable (qualitative or quantitative), well-known statistical tests can be applied to assess validity.

  13. Intra-operative Localization of Brachytherapy Implants Using Intensity-based Registration

    PubMed Central

    KarimAghaloo, Z.; Abolmaesumi, P.; Ahmidi, N.; Chen, T.K.; Gobbi, D. G.; Fichtinger, G.

    2010-01-01

    In prostate brachytherapy, a transrectal ultrasound (TRUS) will show the prostate boundary but not all the implanted seeds, while fluoroscopy will show all the seeds clearly but not the boundary. We propose an intensity-based registration between TRUS images and the implant reconstructed from uoroscopy as a means of achieving accurate intra-operative dosimetry. The TRUS images are first filtered and compounded, and then registered to the uoroscopy model via mutual information. A training phantom was implanted with 48 seeds and imaged. Various ultrasound filtering techniques were analyzed, and the best results were achieved with the Bayesian combination of adaptive thresholding, phase congruency, and compensation for the non-uniform ultrasound beam profile in the elevation and lateral directions. The average registration error between corresponding seeds relative to the ground truth was 0.78 mm. The effect of false positives and false negatives in ultrasound were investigated by masking true seeds in the uoroscopy volume or adding false seeds. The registration error remained below 1.01 mm when the false positive rate was 31%, and 0.96 mm when the false negative rate was 31%. This fully automated method delivers excellent registration accuracy and robustness in phantom studies, and promises to demonstrate clinically adequate performance on human data as well. Keywords: Prostate brachytherapy, Ultrasound, Fluoroscopy, Registration. PMID:21152376

  14. Evaluation of Second-Level Inference in fMRI Analysis

    PubMed Central

    Roels, Sanne P.; Loeys, Tom; Moerkerke, Beatrijs

    2016-01-01

    We investigate the impact of decisions in the second-level (i.e., over subjects) inferential process in functional magnetic resonance imaging on (1) the balance between false positives and false negatives and on (2) the data-analytical stability, both proxies for the reproducibility of results. Second-level analysis based on a mass univariate approach typically consists of 3 phases. First, one proceeds via a general linear model for a test image that consists of pooled information from different subjects. We evaluate models that take into account first-level (within-subjects) variability and models that do not take into account this variability. Second, one proceeds via inference based on parametrical assumptions or via permutation-based inference. Third, we evaluate 3 commonly used procedures to address the multiple testing problem: familywise error rate correction, False Discovery Rate (FDR) correction, and a two-step procedure with minimal cluster size. Based on a simulation study and real data we find that the two-step procedure with minimal cluster size results in most stable results, followed by the familywise error rate correction. The FDR results in most variable results, for both permutation-based inference and parametrical inference. Modeling the subject-specific variability yields a better balance between false positives and false negatives when using parametric inference. PMID:26819578

  15. Custom Array Comparative Genomic Hybridization: the Importance of DNA Quality, an Expert Eye, and Variant Validation

    PubMed Central

    Lantieri, Francesca; Malacarne, Michela; Gimelli, Stefania; Santamaria, Giuseppe; Coviello, Domenico; Ceccherini, Isabella

    2017-01-01

    The presence of false positive and false negative results in the Array Comparative Genomic Hybridization (aCGH) design is poorly addressed in literature reports. We took advantage of a custom aCGH recently carried out to analyze its design performance, the use of several Agilent aberrations detection algorithms, and the presence of false results. Our study provides a confirmation that the high density design does not generate more noise than standard designs and, might reach a good resolution. We noticed a not negligible presence of false negative and false positive results in the imbalances call performed by the Agilent software. The Aberration Detection Method 2 (ADM-2) algorithm with a threshold of 6 performed quite well, and the array design proved to be reliable, provided that some additional filters are applied, such as considering only intervals with average absolute log2ratio above 0.3. We also propose an additional filter that takes into account the proportion of probes with log2ratio exceeding suggestive values for gain or loss. In addition, the quality of samples was confirmed to be a crucial parameter. Finally, this work raises the importance of evaluating the samples profiles by eye and the necessity of validating the imbalances detected. PMID:28287439

  16. Bayesian truthing and experimental validation in homeland security and defense

    NASA Astrophysics Data System (ADS)

    Jannson, Tomasz; Forrester, Thomas; Wang, Wenjian; Kostrzewski, Andrew; Pradhan, Ranjit

    2014-05-01

    In this paper we discuss relations between Bayesian Truthing (experimental validation), Bayesian statistics, and Binary Sensing in the context of selected Homeland Security and Intelligence, Surveillance, Reconnaissance (ISR) optical and nonoptical application scenarios. The basic Figure of Merit (FoM) is Positive Predictive Value (PPV), as well as false positives and false negatives. By using these simple binary statistics, we can analyze, classify, and evaluate a broad variety of events including: ISR; natural disasters; QC; and terrorism-related, GIS-related, law enforcement-related, and other C3I events.

  17. Hepatitis C Virus Core Mutations Associated with False-Negative Serological Results for Genotype 3a Core Antigen

    PubMed Central

    Dunford, Linda; Freitas, Ines; Holder, Paul; Nguyen, Lan Anh; O'Gorman, Joanne; Connell, Jeff; Carr, Michael; Hall, William; De Gascun, Cillian

    2015-01-01

    Genetic characterization of the genotype 3a (GT3a) hepatitis C virus (HCV) core region from HCV core antigen (HCVcAg)-negative/RNA-positive cases and HCVcAg-positive/RNA-positive controls identified significant associations between the substitutions A48T and T49A/P and failure to detect HCVcAg (P < 0.05). Polymorphisms at residues 48 and 49 in the core protein are present across all major epidemic and endemic GTs. These findings have implications for HCV diagnosis, particularly in low-income regions in which GT3a HCV is endemic. PMID:25994168

  18. The positive and negative consequences of multiple-choice testing.

    PubMed

    Roediger, Henry L; Marsh, Elizabeth J

    2005-09-01

    Multiple-choice tests are commonly used in educational settings but with unknown effects on students' knowledge. The authors examined the consequences of taking a multiple-choice test on a later general knowledge test in which students were warned not to guess. A large positive testing effect was obtained: Prior testing of facts aided final cued-recall performance. However, prior testing also had negative consequences. Prior reading of a greater number of multiple-choice lures decreased the positive testing effect and increased production of multiple-choice lures as incorrect answers on the final test. Multiple-choice testing may inadvertently lead to the creation of false knowledge.

  19. Automatic mouse ultrasound detector (A-MUD): A new tool for processing rodent vocalizations

    PubMed Central

    Reitschmidt, Doris; Noll, Anton; Balazs, Peter; Penn, Dustin J.

    2017-01-01

    House mice (Mus musculus) emit complex ultrasonic vocalizations (USVs) during social and sexual interactions, which have features similar to bird song (i.e., they are composed of several different types of syllables, uttered in succession over time to form a pattern of sequences). Manually processing complex vocalization data is time-consuming and potentially subjective, and therefore, we developed an algorithm that automatically detects mouse ultrasonic vocalizations (Automatic Mouse Ultrasound Detector or A-MUD). A-MUD is a script that runs on STx acoustic software (S_TOOLS-STx version 4.2.2), which is free for scientific use. This algorithm improved the efficiency of processing USV files, as it was 4–12 times faster than manual segmentation, depending upon the size of the file. We evaluated A-MUD error rates using manually segmented sound files as a ‘gold standard’ reference, and compared them to a commercially available program. A-MUD had lower error rates than the commercial software, as it detected significantly more correct positives, and fewer false positives and false negatives. The errors generated by A-MUD were mainly false negatives, rather than false positives. This study is the first to systematically compare error rates for automatic ultrasonic vocalization detection methods, and A-MUD and subsequent versions will be made available for the scientific community. PMID:28727808

  20. Quantitative assessment of hit detection and confirmation in single and duplicate high-throughput screenings.

    PubMed

    Wu, Zhijin; Liu, Dongmei; Sui, Yunxia

    2008-02-01

    The process of identifying active targets (hits) in high-throughput screening (HTS) usually involves 2 steps: first, removing or adjusting for systematic variation in the measurement process so that extreme values represent strong biological activity instead of systematic biases such as plate effect or edge effect and, second, choosing a meaningful cutoff on the calculated statistic to declare positive compounds. Both false-positive and false-negative errors are inevitable in this process. Common control or estimation of error rates is often based on an assumption of normal distribution of the noise. The error rates in hit detection, especially false-negative rates, are hard to verify because in most assays, only compounds selected in primary screening are followed up in confirmation experiments. In this article, the authors take advantage of a quantitative HTS experiment in which all compounds are tested 42 times over a wide range of 14 concentrations so true positives can be found through a dose-response curve. Using the activity status defined by dose curve, the authors analyzed the effect of various data-processing procedures on the sensitivity and specificity of hit detection, the control of error rate, and hit confirmation. A new summary score is proposed and demonstrated to perform well in hit detection and useful in confirmation rate estimation. In general, adjusting for positional effects is beneficial, but a robust test can prevent overadjustment. Error rates estimated based on normal assumption do not agree with actual error rates, for the tails of noise distribution deviate from normal distribution. However, false discovery rate based on empirically estimated null distribution is very close to observed false discovery proportion.

  1. International validation study for interim PET in ABVD-treated, advanced-stage hodgkin lymphoma: interpretation criteria and concordance rate among reviewers.

    PubMed

    Biggi, Alberto; Gallamini, Andrea; Chauvie, Stephane; Hutchings, Martin; Kostakoglu, Lale; Gregianin, Michele; Meignan, Michel; Malkowski, Bogdan; Hofman, Michael S; Barrington, Sally F

    2013-05-01

    At present, there are no standard criteria that have been validated for interim PET reporting in lymphoma. In 2009, an international workshop attended by hematologists and nuclear medicine experts in Deauville, France, proposed to develop simple and reproducible rules for interim PET reporting in lymphoma. Accordingly, an international validation study was undertaken with the primary aim of validating the prognostic role of interim PET using the Deauville 5-point score to evaluate images and with the secondary aim of measuring concordance rates among reviewers using the same 5-point score. This paper focuses on the criteria for interpretation of interim PET and on concordance rates. A cohort of advanced-stage Hodgkin lymphoma patients treated with doxorubicin, bleomycin, vinblastine, and dacarbazine (ABVD) were enrolled retrospectively from centers worldwide. Baseline and interim scans were reviewed by an international panel of 6 nuclear medicine experts using the 5-point score. Complete scan datasets of acceptable diagnostic quality were available for 260 of 440 (59%) enrolled patients. Independent agreement among reviewers was reached on 252 of 260 patients (97%), for whom at least 4 reviewers agreed the findings were negative (score of 1-3) or positive (score of 4-5). After discussion, consensus was reached in all cases. There were 45 of 260 patients (17%) with positive interim PET findings and 215 of 260 patients (83%) with negative interim PET findings. Thirty-three interim PET-positive scans were true-positive, and 12 were false-positive. Two hundred three interim PET-negative scans were true-negative, and 12 were false-negative. Sensitivity, specificity, and accuracy were 0.73, 0.94, and 0.91, respectively. Negative predictive value and positive predictive value were 0.94 and 0.73, respectively. The 3-y failure-free survival was 83%, 28%, and 95% for the entire population and for interim PET-positive and -negative patients, respectively (P < 0.0001). The agreement between pairs of reviewers was good or very good, ranging from 0.69 to 0.84 as measured with the Cohen kappa. Overall agreement was good at 0.76 as measured with the Krippendorf α. The 5-point score proposed at Deauville for reviewing interim PET scans in advanced Hodgkin lymphoma is accurate and reproducible enough to be accepted as a standard reporting criterion in clinical practice and for clinical trials.

  2. Hydrogen breath test in schoolchildren.

    PubMed Central

    Douwes, A C; Schaap, C; van der Klei-van Moorsel, J M

    1985-01-01

    The frequency of negative hydrogen breath tests due to colonic bacterial flora which are unable to produce hydrogen was determined after oral lactulose challenge in 98 healthy Dutch schoolchildren. There was a negative result in 9.2%. The probability of a false normal lactose breath test (1:77) was calculated from these results together with those from a separate group of children with lactose malabsorption (also determined by hydrogen breath test). A study of siblings and mothers of subjects with a negative breath test did not show familial clustering of this condition. Faecal incubation tests with various sugars showed an increase in breath hydrogen greater than 100 parts per million in those with a positive breath test while subjects with a negative breath test also had a negative faecal incubation test. The frequency of a false negative hydrogen breath test was higher than previously reported, but this does not affect the superiority of this method of testing over the conventional blood glucose determination. PMID:4004310

  3. Diagnostic sensitivity and specificity of in situ hybridization and immunohistochemistry for Eastern equine encephalitis virus and West Nile virus in formalin-fixed, paraffin-embedded brain tissue of horses.

    PubMed

    Pennick, Kate E; McKnight, Christy A; Patterson, Jon S; Latimer, Kenneth S; Maes, Roger K; Wise, Annabel G; Kiupel, Matti

    2012-03-01

    Immunohistochemistry (IHC) and in situ hybridization (ISH) can be used either to detect or to differentiate between Eastern equine encephalitis virus (EEEV) and West Nile virus (WNV) within formalin-fixed, paraffin-embedded (FFPE) brain tissue of horses. To compare the diagnostic sensitivity and specificity of ISH and IHC, FFPE brain tissue from 20 EEEV-positive horses and 16 WNV-positive horses were tested with both EEEV and WNV oligoprobes and EEEV- and WNV-specific antibodies. Reverse transcription polymerase chain reaction (RT-PCR) for detection of EEEV and WNV was used as the gold standard to confirm infection. All horses that tested positive for EEEV by RT-PCR also tested positive by IHC and ISH, except for 1 case that was false-negative by ISH. In contrast, all horses that tested positive for WNV by RT-PCR tested negative by IHC and only 2 horses tested positive by ISH. No false-positives were detected with either method for both viruses. Both IHC and ISH are highly specific and sensitive diagnostic methods to detect EEEV in equine FFPE brain tissues, although neither appear effective for the diagnosis of WNV in equine neurologic cases.

  4. Focused abdominal sonography for trauma (FAST) in blunt paediatric abdominal trauma.

    PubMed

    Faruque, Ahmad Vaqas; Qazi, Saqib Hamid; Khan, Muhammad Arif Mateen; Akhtar, Wassem; Majeed, Amina

    2013-03-01

    To evaluate the role of focussed abdominal sonography for trauma in blunt paediatric abdominal trauma patients, and to see if the role of computed tomography scan could be limited to only those cases in which sonography was positive. The retrospective study covered 10 years, from January 1,2000 to December 31,2009, and was conducted at the Department of Radiology and Department of Emergency Medicine, Aga Khan University Hospital, Karachi. It comprised cases of 174 children from birth to 14 years who had presented with blunt abdominal trauma and had focussed abdominal sonography for trauma done at the hospital. The findings were correlated with computed tomography scan of the abdomen and clinical follow-up. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of focussed abdominal sonography for trauma were calculated for blunt abdominal trauma. SPSS 17 was used for statistical analysis. Of the total 174 cases, 31 (17.81%) were later confirmed by abdominal scan. Of these 31 children, sonography had been positive in 29 (93.54%) children. In 21 (67.74%) of the 31 children, sonograpy had been true positive; 8 (25%) (8/31) were false positive; and 2 (6%) (2/31) were false negative. There were 6 (19.3%) children in which sonography was positive and converted to laparotomy. There was no significant difference on account of gender (p>0.356). Focussed abdominal sonography for trauma in the study had sensitivity of 91%, specificity of 95%, positive predictive value of 73%, and negative predictive value of 73% with accuracy of 94%. All patients who had negative sonography were discharged later, and had no complication on clinical follow-up. Focussed abdominal sonography for trauma is a fairly reliable mode to assess blunt abdominal trauma in children. It is a useful tool to pick high-grade solid and hollow viscous injury. The results suggest that the role of computed tomography scan can be limited to those cases in which focussed sonography is positive.

  5. The Influence of Feedback of Diagnosis and Executive Function Skills on Rates of False Positive and False Negative Outcomes for ADHD

    ERIC Educational Resources Information Center

    Bender, Stacy L.; Privitera, Gregory J.

    2016-01-01

    This study examined executive function (EF) skills and self-reported symptoms of ADHD. EF skills were measured to determine whether skills were different between groups that reported clinical levels of ADHD symptoms (clinical group) and nonclinical levels of ADHD symptoms (nonclinical group). EF skills in the nonclinical group were also…

  6. False-positive IgM for CMV in pregnant women with autoimmune disease: a novel prognostic factor for poor pregnancy outcome.

    PubMed

    De Carolis, S; Santucci, S; Botta, A; Garofalo, S; Martino, C; Perrelli, A; Salvi, S; Degennaro, Va; de Belvis, Ag; Ferrazzani, S; Scambia, G

    2010-06-01

    Our aims were to assess the frequency of false-positive IgM antibodies for cytomegalovirus in pregnant women with autoimmune diseases and in healthy women (controls) and to determine their relationship with pregnancy outcome. Data from 133 pregnancies in 118 patients with autoimmune diseases and from 222 pregnancies in 198 controls were assessed. When positive IgM for cytomegalovirus was detected, IgG avidity, cytomegalovirus isolation and polymerase chain reaction for CMV-DNA in maternal urine and amniotic fluid samples were performed in order to identify primary infection or false positivity. A statistically significantly higher rate of false-positive IgM was found in pregnancies with autoimmune diseases (16.5%) in comparison with controls (0.9%). A worse pregnancy outcome was observed among patients with autoimmune disease and false cytomegalovirus IgM in comparison with those without false positivity: earlier week of delivery (p = 0.017), lower neonatal birth weight (p = 0.0004) and neonatal birth weight percentile (p = 0.002), higher rate of intrauterine growth restriction (p = 0.02) and babies weighing less than 2000 g (p = 0.025) were encountered. The presence of false cytomegalovirus IgM in patients with autoimmune diseases could be used as a novel prognostic index of poor pregnancy outcome: it may reflect a non-specific activation of the immune system that could negatively affect pregnancy outcome. Lupus (2010) 19, 844-849.

  7. Splenomegaly Segmentation using Global Convolutional Kernels and Conditional Generative Adversarial Networks

    PubMed Central

    Huo, Yuankai; Xu, Zhoubing; Bao, Shunxing; Bermudez, Camilo; Plassard, Andrew J.; Liu, Jiaqi; Yao, Yuang; Assad, Albert; Abramson, Richard G.; Landman, Bennett A.

    2018-01-01

    Spleen volume estimation using automated image segmentation technique may be used to detect splenomegaly (abnormally enlarged spleen) on Magnetic Resonance Imaging (MRI) scans. In recent years, Deep Convolutional Neural Networks (DCNN) segmentation methods have demonstrated advantages for abdominal organ segmentation. However, variations in both size and shape of the spleen on MRI images may result in large false positive and false negative labeling when deploying DCNN based methods. In this paper, we propose the Splenomegaly Segmentation Network (SSNet) to address spatial variations when segmenting extraordinarily large spleens. SSNet was designed based on the framework of image-to-image conditional generative adversarial networks (cGAN). Specifically, the Global Convolutional Network (GCN) was used as the generator to reduce false negatives, while the Markovian discriminator (PatchGAN) was used to alleviate false positives. A cohort of clinically acquired 3D MRI scans (both T1 weighted and T2 weighted) from patients with splenomegaly were used to train and test the networks. The experimental results demonstrated that a mean Dice coefficient of 0.9260 and a median Dice coefficient of 0.9262 using SSNet on independently tested MRI volumes of patients with splenomegaly.

  8. False positive rate of carbon monoxide saturation by pulse oximetry of emergency department patients.

    PubMed

    Weaver, Lindell K; Churchill, Susan K; Deru, Kayla; Cooney, Darryl

    2013-02-01

    Symptoms of carbon monoxide (CO) poisoning are non-specific. Diagnosis requires suspicion of exposure, confirmed by measuring ambient CO levels or carboxyhemoglobin (COHb). An FDA-approved pulse oximeter (Rad-57) can measure CO saturation (S(pCO)). The device accuracy has implications for clinical decision-making. From April 1 to August 15, 2008, study personnel measured S(pCO) and documented demographic factors at time of clinical blood draw, in a convenience sample of 1,363 subjects presenting to the emergency department at Intermountain Medical Center, Murray, Utah. The technician then assayed COHb. COHb and S(pCO) values were compared by subject; false positive or negative values were defined as S(pCO) at least 3 percentage points greater or less than COHb level, reported by the manufacturer to be ± 1 SD in performance. In 1,363 subjects, 613 (45%) were male, 1,141 (84%) were light-skinned, 14 in shock, 4 with CO poisoning, and 122 (9%) met the criteria for a false positive value (range 3-19 percentage points), while 247 (18%) met the criteria for a false negative value (-13 to -3 percentage points). Risks for a false positive S(pCO) reading included being female and having a lower perfusion index. Methemoglobin, body temperature, and blood pressure also appear to influence the S(pCO) accuracy. There was variability among monitors, possibly related to technician technique, as rotation of monitors among technicians was not enforced. While the Rad-57 pulse oximeter functioned within the manufacturer's specifications, clinicians using the Rad-57 should expect some S(pCO) readings to be significantly higher or lower than COHb measurements, and should not use S(pCO) to direct triage or patient management. An elevated S(pCO) could broaden the diagnosis of CO poisoning in patients with non-specific symptoms. However, a negative S(pCO) level in patients suspected of having CO poisoning should never rule out CO poisoning, and should always be confirmed by COHb. © 2013 Daedalus Enterprises.

  9. 49 CFR 40.149 - May the MRO change a verified drug test result?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... identifying (e.g., a paperwork mistake) or testing (e.g., a false positive or negative) the employee's primary... result only in the following situations: (1) When you have reopened a verification that was done without... laboratory notifies you that it mixed up the two test results, and X was really negative and Y was really...

  10. 49 CFR 40.149 - May the MRO change a verified drug test result?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... identifying (e.g., a paperwork mistake) or testing (e.g., a false positive or negative) the employee's primary... result only in the following situations: (1) When you have reopened a verification that was done without... laboratory notifies you that it mixed up the two test results, and X was really negative and Y was really...

  11. 49 CFR 40.149 - May the MRO change a verified drug test result?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... identifying (e.g., a paperwork mistake) or testing (e.g., a false positive or negative) the employee's primary... result only in the following situations: (1) When you have reopened a verification that was done without... laboratory notifies you that it mixed up the two test results, and X was really negative and Y was really...

  12. 49 CFR 40.149 - May the MRO change a verified drug test result?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... identifying (e.g., a paperwork mistake) or testing (e.g., a false positive or negative) the employee's primary... result only in the following situations: (1) When you have reopened a verification that was done without... laboratory notifies you that it mixed up the two test results, and X was really negative and Y was really...

  13. Rating the "Raters": Legal Exposure of Trustmark Authorities in the Context of Consumer Health Informatics

    PubMed Central

    Terry, Nicolas P

    2000-01-01

    There are three areas of potential legal exposure for an organization such as a trustmark authority involved in ehealth quality rating. First, an ehealth provider may make a complaint about negative or impliedly negative ratings rendered by the ratings body (false negative). Typically, a negative ratings complaint would rely on defamation or product disparagement causes of action. In some cases such complaints could be defended on the basis of absence of malice (US). Second, the rating body might render a positive rating on ehealth data that a third party allegedly relied upon and suffered injury (false positive). While the primary cause of action would be against the ehealth data provider, questions may arise as to possible liability of the trustmark authority. For example, some US liability exposure is possible based on cases involving the potential liability of product warrantors, trade associations and certifiers or endorsers. Third, a ratings body may face public law liability for its own web misfeasance. Several risk management approaches are possible and would not necessarily be mutually exclusive. These approaches will require careful investigation to assess their risk reduction potential and, in some cases, legislation.

  14. Rating the Raters: Legal Exposure of Trustmark Authorities in the Context of Consumer Health Informatics

    PubMed Central

    2000-01-01

    There are three areas of potential legal exposure for an organization such as a trustmark authority involved in e-health quality rating. First, an e-health provider may make a complaint about negative or impliedly negative ratings rendered by the ratings body (false negative). Typically, a negative ratings complaint would rely on defamation or product disparagement causes of action. In some cases such complaints could be defended on the basis of absence of malice (US). Second, the rating body might render a positive rating on e-health data that a third party allegedly relied upon and suffered injury (false positive). While the primary cause of action would be against the e-health data provider, questions may arise as to the possible liability of the trustmark authority. For example, some US liability exposure is possible based on cases involving the potential liability of product warrantors, trade associations, and certifiers or endorsers. Third, a ratings body may face public law liability for its own web misfeasance. Several risk management approaches are possible and would not necessarily be mutually exclusive. These approaches will require careful investigation to assess their risk reduction potential and, in some cases, the introduction of legislation. PMID:11720941

  15. Rating the raters: legal exposure of trustmark authorities in the context of consumer health informatics.

    PubMed

    Terry, N P

    2000-01-01

    There are three areas of potential legal exposure for an organization such as a trustmark authority involved in e-health quality rating. First, an e-health provider may make a complaint about negative or impliedly negative ratings rendered by the ratings body (false negative). Typically, a negative ratings complaint would rely on defamation or product disparagement causes of action. In some cases such complaints could be defended on the basis of absence of malice (US). Second, the rating body might render a positive rating on e-health data that a third party allegedly relied upon and suffered injury (false positive). While the primary cause of action would be against the e-health data provider, questions may arise as to the possible liability of the trustmark authority. For example, some US liability exposure is possible based on cases involving the potential liability of product warrantors, trade associations, and certifiers or endorsers. Third, a ratings body may face public law liability for its own web misfeasance. Several risk management approaches are possible and would not necessarily be mutually exclusive. These approaches will require careful investigation to assess their risk reduction potential and, in some cases, the introduction of legislation.

  16. Accuracy of self-reports of fecal occult blood tests and test results among individuals in the carpentry trade.

    PubMed

    Lipkus, Isaac M; Samsa, Gregory P; Dement, John; Skinner, Celette Sugg; Green, La Sonya G; Pompeii, Lisa; Ransohoff, David F

    2003-11-01

    Inaccuracy in self-reports of colorectal cancer (CRC) screening procedures (e.g., over- or underreporting) may interfere with individuals adhering to appropriate screening intervals, and can blur the true effects of physician recommendations to screen and the effects of interventions designed to promote screening. We assessed accuracy of self-report of having a fecal occult blood test (FOBT) within a 1-year window based on receipt of FOBT kits among individuals aged 50 and older in the carpentry trade (N = 658) who were off-schedule for having had a FOBT. Indices of evaluating accuracy of self-reports (concordance, specificity, false-positive and false-negative rates) were calculated relative to receipt of a mailed FOBT. Among those who mailed a completed FOBT, we assessed accuracy of reporting the test result. Participants underestimated having performed a FOBT (false-negative rate of 44%). Accuracy was unrelated to perceptions of getting or worrying about CRC or family history. Self-reports of having a negative FOBT result more consistently matched the laboratory result (specificity 98%) than having a positive test result (sensitivity 63%). Contrary to other findings, participants under- rather than over reported FOBT screening. Results suggest greater efforts are needed to enhance accurate recall of FOBT screening.

  17. Prospective assessment of Platelia Aspergillus galactomannan antigen for the diagnosis of invasive aspergillosis in lung transplant recipients.

    PubMed

    Husain, Shahid; Kwak, Eun Jeong; Obman, Asia; Wagener, Marilyn M; Kusne, Shimon; Stout, Janet E; McCurry, Kenneth R; Singh, Nina

    2004-05-01

    The clinical utility of Platelia trade mark Aspergillus galactomannan antigen for the early diagnosis of invasive aspergillosis was prospectively assessed in 70 consecutive lung transplant recipients. Sera were collected twice weekly and tested for galactomannan. Invasive aspergillosis was documented in 17.1% (12/70) of the patients. Using the generalized estimating equation model, at the cutoff value of >or= 0.5, the sensitivity of the test was 30%, specificity 93% with positive and negative likelihood ratios of 4.2 and 0.75, respectively. Increasing the cutoff value to >or= 0.66 yielded a sensitivity of 30%, specificity of 95%, and positive and negative likelihood ratios of 5.5 and 0.74. A total of 14 patients had false-positive tests, including nine who had cystic fibrosis or chronic obstructive pulmonary disease. False-positive tests occurred within 3 days of transplantation in 43% (6/14) of the patients, and within 7 days in 64% (9/14). Thus, the test demonstrated excellent specificity, but a low sensitivity for the diagnosis of aspergillosis in this patient population. Patients with cystic fibrosis or chronic obstructive pulmonary disease may transiently have a positive test in the early post-transplant period.

  18. A national study of breast and colorectal cancer patients' decision-making for novel personalized medicine genomic diagnostics.

    PubMed

    Issa, Amalia M; Tufail, Waqas; Atehortua, Nelson; McKeever, John

    2013-05-01

    Molecular diagnostics are increasingly being used to help guide decision-making for personalized medical treatment of breast and colorectal cancer patients. The main aim of this study was to better understand and determine breast and colorectal cancer patients' decision-making strategies and the trade-offs they make in deciding about characteristics of molecular genomic diagnostics for breast and colorectal cancer. We surveyed a nationally representative sample of 300 breast and colorectal cancer patients using a previously developed web-administered instrument. Eligibility criteria included patients aged 18 years and older with either breast or colorectal cancer. We explored several attributes and attribute levels of molecular genomic diagnostics in 20 scenarios. Our analysis revealed that both breast and colorectal cancer patients weighted the capability of molecular genomic diagnostics to determine the probability of treatment efficacy as being of greater importance than information provided to detect adverse events. The probability of either false-positive or -negative results was ranked highly as a potential barrier by both breast and colorectal patients. However, 78.6% of breast cancer patients ranked the possibility of a 'false-negative test result leading to undertreatment' higher than the 'chance of a false positive, which may lead to overtreatment' (68%). This finding contrasted with the views of colorectal cancer patients who ranked the chance of a false positive as being of greater concern than a false negative (72.8 vs 63%). Overall, cancer patients exhibited a high willingness to accept and pay for genomic diagnostic tests, especially among breast cancer patients. Cancer patients seek a test accuracy rate of 90% or higher. Breast and colorectal cancer patients' decisions about genomic diagnostics are influenced more by the probability of being cured than by avoiding potential severe adverse events. This study provides insights into the relative weight that breast and colorectal cancer patients place on various aspects of molecular genomic diagnostics, and the trade-offs they are willing to make among attributes of such tests.

  19. A retrospective comparison of false negative skin test rates in penicillin allergy, using pencilloyl-poly-lysine and minor determinants or Penicillin G, followed by open challenge.

    PubMed

    Rosenfield, Lana; Kalicinsky, Chrystyna; Warrington, Richard

    2015-01-01

    A history of penicillin allergy in patients is common, but only 10-15 % are truly allergic. While the gold standard for diagnosing penicillin allergy is challenge, it is not recommended that this be done without first carrying out diagnostic skin testing. This is carried out with the major determinant benzylpenicilloyl (PPL) and the minor determinant mixture (MDM), consisting of penilloate, penicilloate and Penicillin G. However, since availability of the MDM is limited, Penicillin G alone has been used. A retrospective chart review was carried out on patients tested for penicillin allergy in the Clinical Immunology and Allergy Clinic at the Health Sciences Centre, Winnipeg, Canada between 2005 and 2013. A total of 521 patients charts were reviewed, of whom 240 had skin testing, ImmunoCap(®) for IgE to Penicillin G and V and had oral challenges with penicillin, amoxicillin or cloxacillin. 17/240 (7.5 %) were skin test positive, 8 to PPL, 4 to MDM and 5 to Penicillin G. One was also positive on ImmunoCap(®) testing. Three patients had negative skin tests but weakly positive ImmunoCap(®). 222 patients with negative skin tests and serological tests were challenged. Of these, 12 patients reacted to challenge. Three of the challenges were equivocal. Of the nine patients with definite positive challenges, three were tested with Penicillin G and six with MDM. Therefore the false negative rates for testing were 2.3 % with PPL and Penicillin G and 6.97 % for PPL and MDM. The difference was not significant (p = 0.0856). In this group of patients with a history of penicillin allergy tested with the major determinant of benzyl penicillin and either MDM or Penicillin G, there was no difference in the rate of false negative testing, based on oral penicillin challenges. Therefore, Penicillin G can be safely used as an alternative to MDM in diagnosing penicillin allergy.

  20. Comparison of Simplexa universal direct PCR with cytotoxicity assay for diagnosis of Clostridium difficile infection: performance, cost, and correlation with disease.

    PubMed

    Landry, Marie L; Ferguson, David; Topal, Jeffrey

    2014-01-01

    Simplexa Clostridium difficile universal direct PCR, a real-time PCR assay for the detection of the C. difficile toxin B (tcdB) gene using the 3M integrated cycler, was compared with a two-step algorithm which includes the C. Diff Chek-60 glutamate dehydrogenase (GDH) antigen assay followed by cytotoxin neutralization. Three hundred forty-two liquid or semisolid stools submitted for diagnostic C. difficile testing, 171 GDH antigen positive and 171 GDH antigen negative, were selected for the study. All samples were tested by the C. Diff Chek-60 GDH antigen assay, cytotoxin neutralization, and Simplexa direct PCR. Of 171 GDH-positive samples, 4 were excluded (from patients on therapy or from whom duplicate samples were obtained) and 88 were determined to be true positives for toxigenic C. difficile. Of the 88, 67 (76.1%) were positive by the two-step method and 86 (97.7%) were positive by PCR. Seventy-nine were positive by the GDH antigen assay only. Of 171 GDH antigen-negative samples, none were positive by PCR. One antigen-negative sample positive by the cytotoxin assay only was deemed a false positive based on chart review. Simplexa C. difficile universal direct PCR was significantly more sensitive for detecting toxigenic C. difficile bacteria than cytotoxin neutralization (P = 0.0002). However, most PCR-positive/cytotoxin-negative patients did not have clear C. difficile disease. The estimated cost avoidance provided by a more rapid molecular diagnosis was outweighed by the cost of isolating and treating PCR-positive/cytotoxin-negative patients. The costs, clinical consequences, and impact on nosocomial transmission of treating and/or isolating patients positive for toxigenic C. difficile by PCR but negative for in vivo toxin production merit further study.

  1. First European interlaboratory comparison of tetracycline and age determination with red fox teeth following oral rabies vaccination programs.

    PubMed

    Robardet, Emmanuelle; Demerson, Jean-Michel; Andrieu, Sabrina; Cliquet, Florence

    2012-10-01

    The first European interlaboratory comparison of tetracycline and age determination with red fox (Vulpes vulpes) tooth samples was organized by the European Union Reference Laboratory for rabies. Performance and procedures implemented by member states were compared. These techniques are widely used to monitor bait uptake in European oral rabies vaccination campaigns. A panel of five red fox half-mandibles comprising one weak positive juvenile sample, two positive adult samples, one negative juvenile sample, and one negative adult sample were sent, along with a technical questionnaire, to 12 laboratories participating on a voluntary basis. The results of only three laboratories (25%) were 100% correct. False-negative results were more frequently seen in weak positive juvenile samples (58%) but were infrequent in positive adult samples (4%), probably due to differences in the ease of reading the two groups of teeth. Four laboratories (44%) had correct results for age determination on all samples. Ages were incorrectly identified in both adult and juvenile samples, with 11 and 17% of discordant results, respectively. Analysis of the technical questionnaires in parallel with test results suggested that all laboratories cutting mandible sections between the canine and first premolar obtained false results. All the laboratories using longitudinal rather than transverse sections and those not using a mounting medium also produced false results. Section thickness appeared to affect the results; no mistakes were found in laboratories using sections <150 μm thick. Factors having a potential impact on the success of laboratories were discussed, and recommendations proposed. Such interlaboratory trials underline the importance of using standardized procedures for biomarker detection in oral rabies vaccination campaigns. Several changes can be made to improve analysis quality and increase the comparability of bait uptake frequencies among member states.

  2. A comparison of acoustic montoring methods for common anurans of the northeastern United States

    USGS Publications Warehouse

    Brauer, Corinne; Donovan, Therese; Mickey, Ruth M.; Katz, Jonathan; Mitchell, Brian R.

    2016-01-01

    Many anuran monitoring programs now include autonomous recording units (ARUs). These devices collect audio data for extended periods of time with little maintenance and at sites where traditional call surveys might be difficult. Additionally, computer software programs have grown increasingly accurate at automatically identifying the calls of species. However, increased automation may cause increased error. We collected 435 min of audio data with 2 types of ARUs at 10 wetland sites in Vermont and New York, USA, from 1 May to 1 July 2010. For each minute, we determined presence or absence of 4 anuran species (Hyla versicolor, Pseudacris crucifer, Anaxyrus americanus, and Lithobates clamitans) using 1) traditional human identification versus 2) computer-mediated identification with software package, Song Scope® (Wildlife Acoustics, Concord, MA). Detections were compared with a data set consisting of verified calls in order to quantify false positive, false negative, true positive, and true negative rates. Multinomial logistic regression analysis revealed a strong (P < 0.001) 3-way interaction between the ARU recorder type, identification method, and focal species, as well as a trend in the main effect of rain (P = 0.059). Overall, human surveyors had the lowest total error rate (<2%) compared with 18–31% total errors with automated methods. Total error rates varied by species, ranging from 4% for A. americanus to 26% for L. clamitans. The presence of rain may reduce false negative rates. For survey minutes where anurans were known to be calling, the odds of a false negative were increased when fewer individuals of the same species were calling.

  3. Evaluation of a system for automatic detection of diabetic retinopathy from color fundus photographs in a large population of patients with diabetes.

    PubMed

    Abràmoff, Michael D; Niemeijer, Meindert; Suttorp-Schulten, Maria S A; Viergever, Max A; Russell, Stephen R; van Ginneken, Bram

    2008-02-01

    To evaluate the performance of a system for automated detection of diabetic retinopathy in digital retinal photographs, built from published algorithms, in a large, representative, screening population. We conducted a retrospective analysis of 10,000 consecutive patient visits, specifically exams (four retinal photographs, two left and two right) from 5,692 unique patients from the EyeCheck diabetic retinopathy screening project imaged with three types of cameras at 10 centers. Inclusion criteria included no previous diagnosis of diabetic retinopathy, no previous visit to ophthalmologist for dilated eye exam, and both eyes photographed. One of three retinal specialists evaluated each exam as unacceptable quality, no referable retinopathy, or referable retinopathy. We then selected exams with sufficient image quality and determined presence or absence of referable retinopathy. Outcome measures included area under the receiver operating characteristic curve (number needed to miss one case [NNM]) and type of false negative. Total area under the receiver operating characteristic curve was 0.84, and NNM was 80 at a sensitivity of 0.84 and a specificity of 0.64. At this point, 7,689 of 10,000 exams had sufficient image quality, 4,648 of 7,689 (60%) were true negatives, 59 of 7,689 (0.8%) were false negatives, 319 of 7,689 (4%) were true positives, and 2,581 of 7,689 (33%) were false positives. Twenty-seven percent of false negatives contained large hemorrhages and/or neovascularizations. Automated detection of diabetic retinopathy using published algorithms cannot yet be recommended for clinical practice. However, performance is such that evaluation on validated, publicly available datasets should be pursued. If algorithms can be improved, such a system may in the future lead to improved prevention of blindness and vision loss in patients with diabetes.

  4. False-negative rate cannot be reduced by lowering the haemoglobin concentration cut-off in colorectal cancer screening using faecal immunochemical test.

    PubMed

    Ibañez-Sanz, Gemma; Garcia, Montse; Milà, Núria; Rodríguez-Moranta, Francisco; Binefa, Gemma; Gómez-Matas, Javier; Benito, Llúcia; Padrol, Isabel; Barenys, Mercè; Moreno, Victor

    2017-09-01

    The aim of this study was to analyse false-negative (FN) results of the faecal immunochemical test (FIT) and its determinants in a colorectal cancer screening programme in Catalonia. We carried out a cross-sectional study among 218 screenees with a negative FIT result who agreed to undergo a colonoscopy. A false-negative result was defined as the detection, at colonoscopy, of intermediate/high-risk polyps or colorectal cancer in a patient with a previous negative FIT (<20 µgHb/g). Multivariate logistic regression models were constructed to identify sociodemographic (sex, age) and screening variables (quantitative faecal haemoglobin, colonoscopy findings) related to FN results. Adjusted odds ratios and their 95% confidence intervals were estimated. There were 15.6% FN FIT results. Faecal haemoglobin was undetected in 45.5% of these results and was below 4 µgHb/g in 94.0% of the individuals with a FN result. About 60% of the lesions were located in the proximal colon, whereas the expected percentage was 30%. Decreasing the positivity threshold of FIT does not increase the detection rate of advanced neoplasia, but may increase the costs and potential adverse effects.

  5. Accuracy of ultrasound for the prediction of placenta accreta.

    PubMed

    Bowman, Zachary S; Eller, Alexandra G; Kennedy, Anne M; Richards, Douglas S; Winter, Thomas C; Woodward, Paula J; Silver, Robert M

    2014-08-01

    Ultrasound has been reported to be greater than 90% sensitive for the diagnosis of accreta. Prior studies may be subject to bias because of single expert observers, suspicion for accreta, and knowledge of risk factors. We aimed to assess the accuracy of ultrasound for the prediction of accreta. Patients with accreta at a single academic center were matched to patients with placenta previa, but no accreta, by year of delivery. Ultrasound studies with views of the placenta were collected, deidentified, blinded to clinical history, and placed in random sequence. Six investigators prospectively interpreted each study for the presence of accreta and findings reported to be associated with its diagnosis. Sensitivity, specificity, positive predictive, negative predictive value, and accuracy were calculated. Characteristics of accurate findings were compared using univariate and multivariate analyses. Six investigators examined 229 ultrasound studies from 55 patients with accreta and 56 controls for 1374 independent observations. 1205/1374 (87.7% overall, 90% controls, 84.9% cases) studies were given a diagnosis. There were 371 (27.0%) true positives; 81 (5.9%) false positives; 533 (38.8%) true negatives, 220 (16.0%) false negatives, and 169 (12.3%) with uncertain diagnosis. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 53.5%, 88.0%, 82.1%, 64.8%, and 64.8%, respectively. In multivariate analysis, true positives were more likely to have placental lacunae (odds ratio [OR], 1.5; 95% confidence interval [CI], 1.4-1.6), loss of retroplacental clear space (OR, 2.4; 95% CI, 1.1-4.9), or abnormalities on color Doppler (OR, 2.1; 95% CI, 1.8-2.4). Ultrasound for the prediction of placenta accreta may not be as sensitive as previously described. Copyright © 2014 Mosby, Inc. All rights reserved.

  6. Comparison of sensitivity and specificity of 4 methods for detection of Giardia duodenalis in feces: immunofluorescence and PCR are superior to microscopy of concentrated iodine-stained samples.

    PubMed

    Gotfred-Rasmussen, Helle; Lund, Marianne; Enemark, Heidi L; Erlandsen, Mogens; Petersen, Eskild

    2016-03-01

    For decades, microscopy of feces after formol-ethylacetate (FEA) concentration and iodine staining has been the routine test for intestinal protozoa. Lately, polymerase chain reaction or fluorescence-labeled parasite-specific antibodies have been introduced, but their place in everyday routine diagnostics has not yet been established. We compared FEA and salt-sugar flotation (SSF) concentration followed by microscopy of iodine-stained concentrate and immunofluorescence assay (IFA) and real-time polymerase chain reaction (qPCR) for detection of Giardia duodenalis in human feces. The median number of Giardia cysts found by FEA in 19 Giardia-positive samples was 50 cysts per gram (CPG), by SSF 350 CPG, by IFA 76,700 CPG, and by qPCR 316,000 CPG. We next tested 455 consecutive samples for presence of Giardia cysts. Using IFA as reference, qPCR had a sensitivity of 91%, specificity of 95.1%, a false-positive rate of 50%, a false-negative rate of 0.48%, a positive predictive value of 50%, and a negative predictive value of 99.5%. In conclusion, qPCR and IFA were significantly more sensitive than microscopy of iodine-stained concentrates using either FEA or SSF. We suggest, when using qPCR, that positive samples are verified by IFA to prevent false-positive results. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Major Threat to Malaria Control Programs by Plasmodium falciparum Lacking Histidine-Rich Protein 2, Eritrea

    PubMed Central

    Berhane, Araia; Anderson, Karen; Mihreteab, Selam; Gresty, Karryn; Rogier, Eric; Mohamed, Salih; Hagos, Filmon; Embaye, Ghirmay; Chinorumba, Anderson; Zehaie, Assefash; Dowd, Simone; Waters, Norman C.; Gatton, Michelle L.; Udhayakumar, Venkatachalam; Cunningham, Jane

    2018-01-01

    False-negative results for Plasmodium falciparum histidine-rich protein (HRP) 2–based rapid diagnostic tests (RDTs) are increasing in Eritrea. We investigated HRP gene 2/3 (pfhrp2/pfhrp3) status in 50 infected patients at 2 hospitals. We showed that 80.8% (21/26) of patients at Ghindae Hospital and 41.7% (10/24) at Massawa Hospital were infected with pfhrp2-negative parasites and 92.3% (24/26) of patients at Ghindae Hospital and 70.8% (17/24) at Massawa Hospital were infected with pfhrp3-negative parasites. Parasite densities between pfhrp2-positive and pfhrp2-negative patients were comparable. All pfhrp2-negative samples had no detectable HRP2/3 antigen and showed negative results for HRP2-based RDTs. pfhrp2-negative parasites were genetically less diverse and formed 2 clusters with no close relationships to parasites from Peru. These parasites probably emerged independently by selection in Eritrea. High prevalence of pfhrp2-negative parasites caused a high rate of false-negative results for RDTs. Determining prevalence of pfhrp2-negative parasites is urgently needed in neighboring countries to assist case management policies. PMID:29460730

  8. Major Threat to Malaria Control Programs by Plasmodium falciparum Lacking Histidine-Rich Protein 2, Eritrea.

    PubMed

    Berhane, Araia; Anderson, Karen; Mihreteab, Selam; Gresty, Karryn; Rogier, Eric; Mohamed, Salih; Hagos, Filmon; Embaye, Ghirmay; Chinorumba, Anderson; Zehaie, Assefash; Dowd, Simone; Waters, Norman C; Gatton, Michelle L; Udhayakumar, Venkatachalam; Cheng, Qin; Cunningham, Jane

    2018-03-01

    False-negative results for Plasmodium falciparum histidine-rich protein (HRP) 2-based rapid diagnostic tests (RDTs) are increasing in Eritrea. We investigated HRP gene 2/3 (pfhrp2/pfhrp3) status in 50 infected patients at 2 hospitals. We showed that 80.8% (21/26) of patients at Ghindae Hospital and 41.7% (10/24) at Massawa Hospital were infected with pfhrp2-negative parasites and 92.3% (24/26) of patients at Ghindae Hospital and 70.8% (17/24) at Massawa Hospital were infected with pfhrp3-negative parasites. Parasite densities between pfhrp2-positive and pfhrp2-negative patients were comparable. All pfhrp2-negative samples had no detectable HRP2/3 antigen and showed negative results for HRP2-based RDTs. pfhrp2-negative parasites were genetically less diverse and formed 2 clusters with no close relationships to parasites from Peru. These parasites probably emerged independently by selection in Eritrea. High prevalence of pfhrp2-negative parasites caused a high rate of false-negative results for RDTs. Determining prevalence of pfhrp2-negative parasites is urgently needed in neighboring countries to assist case management policies.

  9. A prospective study: Is handheld micropower impulse radar technology (Pneumoscan) a promising method to detect pneumothorax?

    PubMed

    Hocagil, Hilal; Hocagil, Abdullah Cüneyt; Karacabey, Sinan; Akkaya, Tuğba; Şimşek, Gözde; Sanrı, Erkman

    2015-09-01

    This study aimed to discuss the effectiveness of Pneumoscan working with micropower impulse radar (MIR) technology in diagnosing pneumothorax (PTX) in the emergency department. Patients with suspicion of PTX and indication for thorax tomography (CT) were included into the study. Findings of the Thorax CT were compared with the results of Pneumoscan. Chi-square and Fisher's exact tests were used in categorical variables. One hundred and fifteen patients were included into the study group; twelve patients presented with PTX diagnosed by CT, 10 of which were detected by Pneumoscan. Thirty-six true negative results, sixty-seven false positive results, and two false negative results were obtained, which resulted in an overall sensitivity of 83.3%, specificity of 35.0% for Pneumoscan. There was no statistically significant difference between the effectiveness of Pneumoscan and CT on the detection of PTX (p=0.33). There was no difference between the size of PTX diagnosed by CT and PTX diagnosed by Pneumoscan (p=0.47). There was no statistically significant difference between Pneumoscan and CT on detecting the localisation of the PTX (p=1.00). For the 10 cases diagnosed by Pneumoscan, mean chest wall thickness was determined as 50.3 mm while mean chest wall thickness for two false negatives diagnosed by Pneumoscan was 56.5 mm. However, no statistically significant difference was found between the chest wall thickness and the effectiveness of Pneumoscan on the detection of the PTX (p=0.77). Among sixty-seven false positives diagnosed by Pneumoscan, 46.3% had additional medical signs such as bronchiectasis, pulmonary consolidation, pulmonary edema or pulmonary tumor when they had a reading with CT. The relationship between having additional medical signs at the reading with CT and the effectiveness of Pneumoscan on the detection of the PTX was investigated and no significant difference was found (p=0.472). Using Pneumoscan to detect PTX is controversial since the device has a high false positive ratio. Wherein, false positive diagnosis can cause unjustifiable chest tube insertion. In addition, the device failed to show the size of the PTX, and therefore, it did not aid in determining the treatment and prognosis on contrary to traditional diagnostic methods. The findings could not demonstrate that the device was efficient in emergency care. Further studies and increasing experience may change this outcome in upcoming years.

  10. Should bedside sonography be used first to diagnose pneumothorax secondary to blunt trauma?

    PubMed

    Donmez, Halil; Tokmak, Turgut Tursem; Yildirim, Afra; Buyukoglan, Hakan; Ozturk, Mehmet; Yaşar Ayaz, Umit; Mavili, Ertugrul

    2012-01-01

    BACKGROUND.: Our purpose was to evaluate the effectiveness of bedside sonography (US) in the detection of pneumothorax secondary to blunt thoracic trauma. METHODS.: In this prospective study, 240 hemithoraces of 120 consecutive patients with multiple trauma were evaluated with chest radiographs (CXR) and bedside thoracic US for the diagnosis of pneumothorax. CT examinations were performed in 68 patients. Fifty-two patients who did not undergo CT examinations were excluded from the study. US examinations were performed independently at bedside by two radiologists who were not informed about CXR and CT findings. CXRs were interpreted by two radiologists who were unaware of the US and CT results. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CXR and US were calculated. RESULTS.: One hundred thirty-six hemithoraces were assessed in 68 patients. A total of 35 pneumothoraces were detected in 33 patients. On US, the diagnosis of pneumothorax was correct in 32 hemithoraces. In 98 hemithoraces without pneumothorax, US was normal. With US examination, there were three false-positive and three false-negative results. The sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of US were 91.4%, 97%, 91.4%, 97%, and 97%, respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CXR were 82.7%, 89.7%, 68.5%, 95%, and 89.5%, respectively. CONCLUSIONS.: Bedside thoracic US is an accurate method that can be used in trauma patients instead of CXR for the detection of pneumothorax. Copyright © 2012 Wiley Periodicals, Inc.

  11. Automated detection of tuberculosis on sputum smeared slides using stepwise classification

    NASA Astrophysics Data System (ADS)

    Divekar, Ajay; Pangilinan, Corina; Coetzee, Gerrit; Sondh, Tarlochan; Lure, Fleming Y. M.; Kennedy, Sean

    2012-03-01

    Routine visual slide screening for identification of tuberculosis (TB) bacilli in stained sputum slides under microscope system is a tedious labor-intensive task and can miss up to 50% of TB. Based on the Shannon cofactor expansion on Boolean function for classification, a stepwise classification (SWC) algorithm is developed to remove different types of false positives, one type at a time, and to increase the detection of TB bacilli at different concentrations. Both bacilli and non-bacilli objects are first analyzed and classified into several different categories including scanty positive, high concentration positive, and several non-bacilli categories: small bright objects, beaded, dim elongated objects, etc. The morphological and contrast features are extracted based on aprior clinical knowledge. The SWC is composed of several individual classifiers. Individual classifier to increase the bacilli counts utilizes an adaptive algorithm based on a microbiologist's statistical heuristic decision process. Individual classifier to reduce false positive is developed through minimization from a binary decision tree to classify different types of true and false positive based on feature vectors. Finally, the detection algorithm is was tested on 102 independent confirmed negative and 74 positive cases. A multi-class task analysis shows high accordance rate for negative, scanty, and high-concentration as 88.24%, 56.00%, and 97.96%, respectively. A binary-class task analysis using a receiver operating characteristics method with the area under the curve (Az) is also utilized to analyze the performance of this detection algorithm, showing the superior detection performance on the high-concentration cases (Az=0.913) and cases mixed with high-concentration and scanty cases (Az=0.878).

  12. Conditions for positive and negative recencies in running memory-span recognition.

    PubMed

    Ruiz, R Marcos; Elosúa, M Rosa

    2013-10-01

    A positive recency effect in a running-span recognition procedure was obtained in Experiment 1 for hits and for intratrial false alarms. In running recall procedures, recency does not fit well with an active updating hypothesis. In Experiment 2, in which the beginning of the target set was marked with a cue upon presentation, the recency effects disappeared. In Experiments 3 and 4 participants were forced to maintain 2 items in memory until the last one was presented for recognition. These three items were the target set. When the last item presentation was uncertain-because of the variable length list-an unexpected negative recency effect appeared. An explanation for this change from positive to negative recency is offered based on the sharing of attentional resources put forward by others for similar procedures. © 2013.

  13. Assessing environmental DNA detection in controlled lentic systems.

    PubMed

    Moyer, Gregory R; Díaz-Ferguson, Edgardo; Hill, Jeffrey E; Shea, Colin

    2014-01-01

    Little consideration has been given to environmental DNA (eDNA) sampling strategies for rare species. The certainty of species detection relies on understanding false positive and false negative error rates. We used artificial ponds together with logistic regression models to assess the detection of African jewelfish eDNA at varying fish densities (0, 0.32, 1.75, and 5.25 fish/m3). Our objectives were to determine the most effective water stratum for eDNA detection, estimate true and false positive eDNA detection rates, and assess the number of water samples necessary to minimize the risk of false negatives. There were 28 eDNA detections in 324, 1-L, water samples collected from four experimental ponds. The best-approximating model indicated that the per-L-sample probability of eDNA detection was 4.86 times more likely for every 2.53 fish/m3 (1 SD) increase in fish density and 1.67 times less likely for every 1.02 C (1 SD) increase in water temperature. The best section of the water column to detect eDNA was the surface and to a lesser extent the bottom. Although no false positives were detected, the estimated likely number of false positives in samples from ponds that contained fish averaged 3.62. At high densities of African jewelfish, 3-5 L of water provided a >95% probability for the presence/absence of its eDNA. Conversely, at moderate and low densities, the number of water samples necessary to achieve a >95% probability of eDNA detection approximated 42-73 and >100 L, respectively. Potential biases associated with incomplete detection of eDNA could be alleviated via formal estimation of eDNA detection probabilities under an occupancy modeling framework; alternatively, the filtration of hundreds of liters of water may be required to achieve a high (e.g., 95%) level of certainty that African jewelfish eDNA will be detected at low densities (i.e., <0.32 fish/m3 or 1.75 g/m3).

  14. Computer-aided diagnosis of contrast-enhanced spectral mammography: A feasibility study.

    PubMed

    Patel, Bhavika K; Ranjbar, Sara; Wu, Teresa; Pockaj, Barbara A; Li, Jing; Zhang, Nan; Lobbes, Mark; Zhang, Bin; Mitchell, J Ross

    2018-01-01

    To evaluate whether the use of a computer-aided diagnosis-contrast-enhanced spectral mammography (CAD-CESM) tool can further increase the diagnostic performance of CESM compared with that of experienced radiologists. This IRB-approved retrospective study analyzed 50 lesions described on CESM from August 2014 to December 2015. Histopathologic analyses, used as the criterion standard, revealed 24 benign and 26 malignant lesions. An expert breast radiologist manually outlined lesion boundaries on the different views. A set of morphologic and textural features were then extracted from the low-energy and recombined images. Machine-learning algorithms with feature selection were used along with statistical analysis to reduce, select, and combine features. Selected features were then used to construct a predictive model using a support vector machine (SVM) classification method in a leave-one-out-cross-validation approach. The classification performance was compared against the diagnostic predictions of 2 breast radiologists with access to the same CESM cases. Based on the SVM classification, CAD-CESM correctly identified 45 of 50 lesions in the cohort, resulting in an overall accuracy of 90%. The detection rate for the malignant group was 88% (3 false-negative cases) and 92% for the benign group (2 false-positive cases). Compared with the model, radiologist 1 had an overall accuracy of 78% and a detection rate of 92% (2 false-negative cases) for the malignant group and 62% (10 false-positive cases) for the benign group. Radiologist 2 had an overall accuracy of 86% and a detection rate of 100% for the malignant group and 71% (8 false-positive cases) for the benign group. The results of our feasibility study suggest that a CAD-CESM tool can provide complementary information to radiologists, mainly by reducing the number of false-positive findings. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Cytokines in pleural liquid for diagnosis of tuberculous pleurisy.

    PubMed

    Yamada, Y; Nakamura, A; Hosoda, M; Kato, T; Asano, T; Tonegawa, K; Itoh, M

    2001-07-01

    An elevated level of adenosine deaminase (ADA) in pleural liquid has been considered as a supplemental diagnostic marker for tuberculous pleurisy. However, this is complicated by false-positives and -negatives. Recently, it has been revealed that various cytokines are intimately involved in the pathognomonic physiology of tuberculosis. In this study, interleukin-8 (IL-8), tumour necrosis factor alpha (TNFalpha) and interferon gamma (IFNgamma) were compared with ADA in pleural liquid of patients with inflammatory (21 cases), malignant (28 cases) and tuberculous (21 cases) disease. The pleural ADA, IL-8, TNFalpha and IFNgamma levels in the tuberculous group were higher than in the other three groups. Analysis of receiver operating characteristic (ROC) curves, to evaluate the utility of the various parameters, demonstrates values for the area under the curve (AUC) of 0.770, 0.875, 0.892 and 0.987, respectively for IL-8, TNFalpha, ADA and IFNgamma. No false-positives were encountered with IFNgamma and only one case with a small volume of pleural liquid was a false-negative. This indicates that IFNgamma is a very reliable marker of tuberculous pleurisy.

  16. Handheld echocardiographic screening for rheumatic heart disease by non-experts.

    PubMed

    Ploutz, Michelle; Lu, Jimmy C; Scheel, Janet; Webb, Catherine; Ensing, Greg J; Aliku, Twalib; Lwabi, Peter; Sable, Craig; Beaton, Andrea

    2016-01-01

    Handheld echocardiography (HAND) has good sensitivity and specificity for rheumatic heart disease (RHD) when performed by cardiologists. However, physician shortages in RHD-endemic areas demand less-skilled users to make RHD screening practical. We examine nurse performance and interpretation of HAND using a simplified approach for RHD screening. Two nurses received training on HAND and a simplified screening approach. Consented students at two schools in Uganda were eligible for participation. A simplified approach (HAND performed and interpreted by a non-expert) was compared with the reference standard (standard portable echocardiography, performed and interpreted by experts according to the 2012 World Heart Federation guidelines). Reasons for false-positive and false-negative HAND studies were identified. A total of 1002 children were consented, with 956 (11.1 years, 41.8% male) having complete data for review. Diagnoses included: 913 (95.5%) children were classified normal, 32 (3.3%) borderline RHD and 11 (1.2%) definite RHD. The simplified approach had a sensitivity of 74.4% (58.8% to 86.5%) and a specificity of 78.8% (76.0% to 81.4%) for any RHD (borderline and definite). Sensitivity improved to 90.9% (58.7% to 98.5%) for definite RHD. Identification and measurement of erroneous colour jets was the most common reason for false-positive studies (n=164/194), while missed mitral regurgitation and shorter regurgitant jet lengths with HAND were the most common reasons for false-negative studies (n=10/11). Non-expert-led HAND screening programmes offer a potential solution to financial and workforce barriers that limit widespread RHD screening. Nurses trained on HAND using a simplified approach had reasonable sensitivity and specificity for RHD screening. Information on reasons for false-negative and false-positive screening studies should be used to inform future training protocols, which could lead to improved screening performance. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Development of a qualitative indirect ELISA for the measurement of rabies virus-specific antibodies from vaccinated dogs and cats.

    PubMed

    Cliquet, F; McElhinney, L M; Servat, A; Boucher, J M; Lowings, J P; Goddard, T; Mansfield, K L; Fooks, A R

    2004-04-01

    A protocol suitable for the detection of rabies virus-specific antibodies in serum samples from companion animals using an enzyme linked immunosorbent assay (ELISA) is described. This method has been used successfully for the qualitative assessment of rabies virus-specific antibodies in serum samples from a cohort of vaccinated dogs and cats. In two initial field studies, a variable population of field samples from the Veterinary Laboratories Agency (VLA), United Kingdom were tested. In the first study (n = 1000), the number of false-positive and false-negative results was 11 samples (1.1%) and 67 samples (6.7%), respectively. In the second study (n = 920), the number of false-positive and false-negative results was 7 samples (0.8%) and 52 samples (5.7%). In a third study, undertaken at l'Agence Française de Sécurité Sanitaire des Aliments (AFSSA), Nancy, France (n = 440), 1 false-positive sample (0.23%) and 91 (20.7%) false-negative samples were identified. Data generated using this prototype ELISA indicate a strong correlation for specificity when compared to the gold standard fluorescent antibody virus neutralisation (FAVN) test. Although the ELISA has a lower sensitivity than the FAVN test, it is a useful tool for rapidly screening serum samples from vaccinated companion animals. Using a cut-off value of 0.6 EU/ml, the sensitivity (R = % from VLA and 79% from AFSSA) and specificity (R = 97.3%) indices between the ELISA compared favourably with data generated using the FAVN test. The major advantages of the ELISA test are that it is a qualitative tool that can be completed in four hours, does not require the use of live virus and can be performed without the need for specialised laboratory containment. This contrasts with 4 days using conventional rabies antibody virus neutralisation assays. Using the current format, the ELISA assay described would be a valuable screening tool for the detection of rabies antibodies from vaccinated domestic animals in combination with other Office International des Epizooties (OIE) accepted serological tests.

  18. Validity of Parent-Reported Vaccination Status for Adolescents Aged 13–17 Years: National Immunization Survey-Teen, 2008

    PubMed Central

    Dorell, Christina G.; Jain, Nidhi; Yankey, David

    2011-01-01

    Objective The validity of parent-reported adolescent vaccination histories has not been assessed. This study evaluated the validity of parent-reported adolescent vaccination histories by a combination of immunization card and recall, and by recall only, compared with medical provider records. Methods We analyzed data from the 2008 National Immunization Survey-Teen. Parents of adolescents aged 13–17 years reported their child's vaccination history either by immunization card and recall (n=3,661) or by recall only (n=12,822) for the hepatitis B (Hep B), measles-mumps-rubella (MMR), varicella (VAR), tetanus-diphtheria/tetanus-diphtheria-acellular pertussis (Td/Tdap), meningococcal conjugate (MCV4), and quadrivalent human papillomavirus (HPV4) (for girls only) vaccines. We validated parental report with medical records. Results Among the immunization card/recall group, vaccines with >20% false-positive reports included MMR (32.3%) and Td/Tdap (36.9%); vaccines with >20% false-negative reports included VAR (35.2%), MCV4 (36.0%), and Tdap (41.9%). Net bias ranged from −25.0 to −0.1 percentage points. Kappa values ranged from 0.22 to 0.92. Among the recall-only group, vaccines with >20% false-positive reports included Hep B (33.9%), MMR (61.4%), VAR (26.2%), and Td/Tdap (60.6%); vaccines with >20% false-negative reports included Hep B (58.9%), MMR (33.7%), VAR (51.6%), Td/Tdap (25.5%), Tdap (50.3%) MCV4 (63.0%), and HPV4 (20.5%). Net bias ranged from −46.0 to 0.5 percentage points. Kappa values ranged from 0.03 to 0.76. Conclusions Validity of parent-reported vaccination histories varies by type of report and vaccine. For recently recommended vaccines, false-negative rates were substantial and higher than false-positive rates, resulting in net underreporting of vaccination rates by both the immunization card/recall and recall-only groups. Provider validation of parent-reported vaccinations is needed for valid surveillance of adolescent vaccination coverage. PMID:21812170

  19. Generating false negatives and false positives for As and Mo concentrations in groundwater due to well installation.

    PubMed

    Wallis, Ilka; Pichler, Thomas

    2018-08-01

    Groundwater monitoring relies on the acquisition of 'representative' groundwater samples, which should reflect the ambient water quality at a given location. However, drilling of a monitoring well for sample acquisition has the potential to perturb groundwater conditions to a point that may prove to be detrimental to the monitoring objective. Following installation of 20 monitoring wells in close geographic proximity in central Florida, opposing concentration trends for As and Mo were observed. In the first year after well installation As and Mo concentrations increased in some wells by a factor of 2, while in others As and Mo concentrations decreased by a factor of up to 100. Given this relatively short period of time, a natural change in groundwater composition of such magnitude is not expected, leaving well installation itself as the likely cause for the observed concentration changes. Hence, initial concentrations were identified as 'false negatives' if concentrations increased with time or as 'false positives' if concentrations decreased. False negatives were observed if concentrations were already high, i.e., the As or Mo were present at the time of drilling. False positives were observed if concentrations were relatively lower, i.e., As or Mo were present at low concentrations of approximately 1 to 2μg/L before drilling, but then released from the aquifer matrix as a result of drilling. Generally, As and Mo were present in the aquifer matrix in either pyrite or organic matter, both of which are susceptible to dissolution if redox conditions change due to the addition of oxygen. Thus, introduction of an oxidant into an anoxic aquifer through use of an oxygen saturated drilling fluid served as the conceptual model for the trends where concentrations decreased with time. Mixing between drilling fluid and groundwater (i.e., dilution) was used as the conceptual model for scenarios where increasing trends were observed. Conceptual models were successfully tested through formulation and application of data-driven reactive transport models, using the USGS code MODFLOW in conjunction with the reactive multicomponent transport code PHT3D. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Inferential Costs of Trait Centrality in Impression Formation: Organization in Memory and Misremembering

    PubMed Central

    Nunes, Ludmila D.; Garcia-Marques, Leonel; Ferreira, Mário B.; Ramos, Tânia

    2017-01-01

    An extension of the DRM paradigm was used to study the impact of central traits (Asch, 1946) in impression formation. Traits corresponding to the four clusters of the implicit theory of personality—intellectual, positive and negative; and social, positive and negative (Rosenberg et al., 1968)—were used to develop lists containing several traits of one cluster and one central trait prototypical of the opposite cluster. Participants engaging in impression formation relative to participants engaging in memorization not only produced higher levels of false memories corresponding to the same cluster of the list traits but, under response time pressure at retrieval, also produced more false memories of the cluster corresponding to the central trait. We argue that the importance of central traits stems from their ability to activate their corresponding semantic space within a specialized associative memory structure underlying the implicit theory of personality. PMID:28878708

  1. LS-CAP: an algorithm for identifying cytogenetic aberrations in hepatocellular carcinoma using microarray data.

    PubMed

    He, Xianmin; Wei, Qing; Sun, Meiqian; Fu, Xuping; Fan, Sichang; Li, Yao

    2006-05-01

    Biological techniques such as Array-Comparative genomic hybridization (CGH), fluorescent in situ hybridization (FISH) and affymetrix single nucleotide pleomorphism (SNP) array have been used to detect cytogenetic aberrations. However, on genomic scale, these techniques are labor intensive and time consuming. Comparative genomic microarray analysis (CGMA) has been used to identify cytogenetic changes in hepatocellular carcinoma (HCC) using gene expression microarray data. However, CGMA algorithm can not give precise localization of aberrations, fails to identify small cytogenetic changes, and exhibits false negatives and positives. Locally un-weighted smoothing cytogenetic aberrations prediction (LS-CAP) based on local smoothing and binomial distribution can be expected to address these problems. LS-CAP algorithm was built and used on HCC microarray profiles. Eighteen cytogenetic abnormalities were identified, among them 5 were reported previously, and 12 were proven by CGH studies. LS-CAP effectively reduced the false negatives and positives, and precisely located small fragments with cytogenetic aberrations.

  2. Methods for consistent forewarning of critical events across multiple data channels

    DOEpatents

    Hively, Lee M.

    2006-11-21

    This invention teaches further method improvements to forewarn of critical events via phase-space dissimilarity analysis of data from biomedical equipment, mechanical devices, and other physical processes. One improvement involves conversion of time-serial data into equiprobable symbols. A second improvement is a method to maximize the channel-consistent total-true rate of forewarning from a plurality of data channels over multiple data sets from the same patient or process. This total-true rate requires resolution of the forewarning indications into true positives, true negatives, false positives and false negatives. A third improvement is the use of various objective functions, as derived from the phase-space dissimilarity measures, to give the best forewarning indication. A fourth improvement uses various search strategies over the phase-space analysis parameters to maximize said objective functions. A fifth improvement shows the usefulness of the method for various biomedical and machine applications.

  3. Advance in diagnosis of female genital tract tumor with laser fluorescence

    NASA Astrophysics Data System (ADS)

    Ding, Ai-Hua; Tseng, Quen; Lian, Shao-Hui

    1998-11-01

    In order to improve the diagnostic accuracy of malignant tumors with laser fluorescence, in 1996, our group successfully created the computerized laser fluorescence spectrograph type II with more reliable images shown overshadowing the naked eye method before 74 cases of female genital tract diseases had been examined by the LFS II resulting in 10 positive cases which were also proven pathologically as malignant tumors, without nay false negative, 3 cases presented suspicious positive but all were proven pathologically as non-tumors lesions, the false positive rate was 4 percent. Our work showed that the method of LFS II can provide a more rapid and accurate diagnosis for the clinical malignant tumors.

  4. Publication bias and the canonization of false facts

    PubMed Central

    Nissen, Silas Boye; Magidson, Tali; Gross, Kevin; Bergstrom, Carl T

    2016-01-01

    Science is facing a “replication crisis” in which many experimental findings cannot be replicated and are likely to be false. Does this imply that many scientific facts are false as well? To find out, we explore the process by which a claim becomes fact. We model the community’s confidence in a claim as a Markov process with successive published results shifting the degree of belief. Publication bias in favor of positive findings influences the distribution of published results. We find that unless a sufficient fraction of negative results are published, false claims frequently can become canonized as fact. Data-dredging, p-hacking, and similar behaviors exacerbate the problem. Should negative results become easier to publish as a claim approaches acceptance as a fact, however, true and false claims would be more readily distinguished. To the degree that the model reflects the real world, there may be serious concerns about the validity of purported facts in some disciplines. DOI: http://dx.doi.org/10.7554/eLife.21451.001 PMID:27995896

  5. Neural basis of stereotype-induced shifts in women's mental rotation performance

    PubMed Central

    Helt, Molly; Jacobs, Emily; Sullivan, Kerry

    2007-01-01

    Recent negative focus on women's academic abilities has fueled disputes over gender disparities in the sciences. The controversy derives, in part, from women's relatively poorer performance in aptitude tests, many of which require skills of spatial reasoning. We used functional magnetic imaging to examine the neural structure underlying shifts in women's performance of a spatial reasoning task induced by positive and negative stereotypes. Three groups of participants performed a task involving imagined rotations of the self. Prior to scanning, the positive stereotype group was exposed to a false but plausible stereotype of women's superior perspective-taking abilities; the negative stereotype group was exposed to the pervasive stereotype that men outperform women on spatial tasks; and the control group received neutral information. The significantly poorer performance we found in the negative stereotype group corresponded to increased activation in brain regions associated with increased emotional load. In contrast, the significantly improved performance we found in the positive stereotype group was associated with increased activation in visual processing areas and, to a lesser degree, complex working memory processes. These findings suggest that stereotype messages affect the brain selectively, with positive messages producing relatively more efficient neural strategies than negative messages. PMID:18985116

  6. Neural basis of stereotype-induced shifts in women's mental rotation performance.

    PubMed

    Wraga, Maryjane; Helt, Molly; Jacobs, Emily; Sullivan, Kerry

    2007-03-01

    Recent negative focus on women's academic abilities has fueled disputes over gender disparities in the sciences. The controversy derives, in part, from women's relatively poorer performance in aptitude tests, many of which require skills of spatial reasoning. We used functional magnetic imaging to examine the neural structure underlying shifts in women's performance of a spatial reasoning task induced by positive and negative stereotypes. Three groups of participants performed a task involving imagined rotations of the self. Prior to scanning, the positive stereotype group was exposed to a false but plausible stereotype of women's superior perspective-taking abilities; the negative stereotype group was exposed to the pervasive stereotype that men outperform women on spatial tasks; and the control group received neutral information. The significantly poorer performance we found in the negative stereotype group corresponded to increased activation in brain regions associated with increased emotional load. In contrast, the significantly improved performance we found in the positive stereotype group was associated with increased activation in visual processing areas and, to a lesser degree, complex working memory processes. These findings suggest that stereotype messages affect the brain selectively, with positive messages producing relatively more efficient neural strategies than negative messages.

  7. Demographic predictors of false negative self-reported tobacco use status in an insurance applicant population.

    PubMed

    Palmier, James; Lanzrath, Brian; Dixon, Ammon; Idowu, Oluseun

    2014-01-01

    To identify and quantify demographic correlates of false-negative self-reporting of tobacco use in life insurance applicants. Several studies have assessed the sensitivity of self-reporting for tobacco use in various populations, but statistical examination of the causes of misreporting has been rarer. The very large (488,000 confirmed tobacco users) sample size, US-wide geographic scope, and unique incentive structure of the life insurance application process permit more robust and insurance industry-specific results in this study. Approximately 6.2 million life insurance applicants for whom both tobacco-use interview questions and a confirmatory urine cotinine test were completed between 1999 and 2012 were evaluated for consistency between self-reported and laboratory-confirmed tobacco-use status. The data set was subjected to logistic regression to identify predictors of false negative self-reports (FNSR). False-negative self-reporting was found to be strongly associated with male gender, applicant ages of less than 30 or greater than 60, and low cotinine positivity rates in the applicant's state of residence. Policy face value was also moderately predictive, values above $500,000 associated with moderately higher FNSR. The findings imply that FNSR in life insurance applicants may be the result of complex interactions among financial incentives, geography and presumptive peer groups, and gender.

  8. Evaluation of neuroendocrine tumors with 99mTc-EDDA/HYNIC TOC.

    PubMed

    Artiko, Vera; Afgan, Aida; Petrović, Jelena; Radović, Branislava; Petrović, Nebojša; Vlajković, Marina; Šobić-Šaranović, Dragana; Obradović, Vladimir

    2016-01-01

    This paper is the short review of our preliminary results obtained with 99mTc-EDDA/HYNIC-TOC. The total of 495 patients with different neuroendocrine tumors were investigated during last few years. There have been 334 true positive (TP), 73 true negative (TN), 6 false positive (FP) and 82 false negative findings (FN). Diagnosis was made according to SPECT findings in 122 patients (25%). The mean T/NT ratio for TP cases was significantly higher (p < 0.01) on SPECT (3.12 ± 1.13) than on whole body scan (2.2 ± 0.75). According to our results, overall sensitivity of the method is 80%, specificity 92%, positive predictive value 98%, negative predictive value 47% and accuracy 82%. Fifteen TP patients underwent therapy with 90Y-DOTATATE. Scintigraphy of neuroendocrine tumors with 99mTc-Tektrotyd is a useful method for diagnosis, staging and follow up of the patients suspected to have neuroendocrine tumors. SPECT had important role in diagnosis. It is also helpful in the appropriate choice of the therapy, including the peptide receptor radionuclide therapy. In the absence of 68Ga-labeled peptides and PET/CT, the special emphasize should be given to application of SPECT/CT as well as to the radioguided surgery.

  9. Impact of round-the-clock CSF Gram stain on empirical therapy for suspected central nervous system infections.

    PubMed

    Tissot, F; Prod'hom, G; Manuel, O; Greub, G

    2015-09-01

    The impact of round-the-clock cerebrospinal fluid (CSF) Gram stain on overnight empirical therapy for suspected central nervous system (CNS) infections was investigated. All consecutive overnight CSF Gram stains between 2006 and 2011 were included. The impact of a positive or a negative test on empirical therapy was evaluated and compared to other clinical and biological indications based on institutional guidelines. Bacterial CNS infection was documented in 51/241 suspected cases. Overnight CSF Gram stain was positive in 24/51. Upon validation, there were two false-positive and one false-negative results. The sensitivity and specificity were 41 and 99 %, respectively. All patients but one had other indications for empirical therapy than Gram stain alone. Upon obtaining the Gram result, empirical therapy was modified in 7/24, including the addition of an appropriate agent (1), addition of unnecessary agents (3) and simplification of unnecessary combination therapy (3/11). Among 74 cases with a negative CSF Gram stain and without formal indication for empirical therapy, antibiotics were withheld in only 29. Round-the-clock CSF Gram stain had a low impact on overnight empirical therapy for suspected CNS infections and was associated with several misinterpretation errors. Clinicians showed little confidence in CSF direct examination for simplifying or withholding therapy before definite microbiological results.

  10. Differences in tuberculin reactivity as determined in a veterans administration employee health screening program.

    PubMed

    Mehta, Sanjay R; MacGruder, Cathy; Looney, David; Johns, Scott; Smith, Davey M

    2009-04-01

    In response to a difference in pricing, the San Diego Veterans Administration Medical Center changed its tuberculin preparation from Tubersol to Aplisol in the fall of 2006. Following the change, an increased number of employee skin test conversions was noted. Employee tuberculin skin test converters from 2006 were screened with the QuantiFERON Gold (QFT-G) gamma interferon release assay. Those employees who tested negative by QFT-G were asked to repeat their skin test with both Tubersol and Aplisol tuberculin preparations. Of the new purified protein derivative converters, 12 of 14 returned for repeat testing with QFT-G, and the assay was negative for 83% (10/12), positive for 8% (1/12), and indeterminate for 8% (1/12) of the individuals. Nine of the individuals who were QFT-G negative agreed to repeat skin testing with both tuberculin preparations, and 7/8 (87.5%) demonstrated reactivity with the Aplisol preparation, while 0/8 (0%) reacted to the Tubersol preparation. A change from Tubersol to Aplisol resulted in elevated tuberculin skin test conversion rates that may be due to false-positive reactions. The differences in skin test reactivity between preparations support CDC guidelines that recommend that institutions should not change tuberculin preparations, as doing so may falsely increase the number of positive reactions.

  11. Prediction of lipoprotein signal peptides in Gram-negative bacteria.

    PubMed

    Juncker, Agnieszka S; Willenbrock, Hanni; Von Heijne, Gunnar; Brunak, Søren; Nielsen, Henrik; Krogh, Anders

    2003-08-01

    A method to predict lipoprotein signal peptides in Gram-negative Eubacteria, LipoP, has been developed. The hidden Markov model (HMM) was able to distinguish between lipoproteins (SPaseII-cleaved proteins), SPaseI-cleaved proteins, cytoplasmic proteins, and transmembrane proteins. This predictor was able to predict 96.8% of the lipoproteins correctly with only 0.3% false positives in a set of SPaseI-cleaved, cytoplasmic, and transmembrane proteins. The results obtained were significantly better than those of previously developed methods. Even though Gram-positive lipoprotein signal peptides differ from Gram-negatives, the HMM was able to identify 92.9% of the lipoproteins included in a Gram-positive test set. A genome search was carried out for 12 Gram-negative genomes and one Gram-positive genome. The results for Escherichia coli K12 were compared with new experimental data, and the predictions by the HMM agree well with the experimentally verified lipoproteins. A neural network-based predictor was developed for comparison, and it gave very similar results. LipoP is available as a Web server at www.cbs.dtu.dk/services/LipoP/.

  12. Prediction of lipoprotein signal peptides in Gram-negative bacteria

    PubMed Central

    Juncker, Agnieszka S.; Willenbrock, Hanni; von Heijne, Gunnar; Brunak, Søren; Nielsen, Henrik; Krogh, Anders

    2003-01-01

    A method to predict lipoprotein signal peptides in Gram-negative Eubacteria, LipoP, has been developed. The hidden Markov model (HMM) was able to distinguish between lipoproteins (SPaseII-cleaved proteins), SPaseI-cleaved proteins, cytoplasmic proteins, and transmembrane proteins. This predictor was able to predict 96.8% of the lipoproteins correctly with only 0.3% false positives in a set of SPaseI-cleaved, cytoplasmic, and transmembrane proteins. The results obtained were significantly better than those of previously developed methods. Even though Gram-positive lipoprotein signal peptides differ from Gram-negatives, the HMM was able to identify 92.9% of the lipoproteins included in a Gram-positive test set. A genome search was carried out for 12 Gram-negative genomes and one Gram-positive genome. The results for Escherichia coli K12 were compared with new experimental data, and the predictions by the HMM agree well with the experimentally verified lipoproteins. A neural network-based predictor was developed for comparison, and it gave very similar results. LipoP is available as a Web server at www.cbs.dtu.dk/services/LipoP/. PMID:12876315

  13. The human false-negative rate of rescreening Pap tests. Measured in a two-arm prospective clinical trial.

    PubMed

    Renshaw, A A; Lezon, K M; Wilbur, D C

    2001-04-25

    Routine quality control rescreening often is used to calculate the false-negative rate (FNR) of gynecologic cytology. Theoretic analysis suggests that this is not appropriate, due to the high FNR of rescreening and the inability to actually measure it. The authors sought to determine the FNR of manual rescreening in a large, prospective, two-arm clinical trial using an analytic instrument in the evaluation. The results of the Autopap System Clinical Trial, encompassing 25,124 analyzed slides, were reviewed. The false-negative and false-positive rates at various thresholds were determined for routine primary screening, routine rescreening, Autopap primary screening, and Autopap rescreening by using a simple, standard methodology. The FNR of routine manual rescreening at the level of atypical squamous cells of undetermined significance (ASCUS) was 73%, more than 3 times the FNR of primary screening; 11 cases were detected. The FNR of Autopap rescreening was 34%; 80 cases were detected. Routine manual rescreening decreased the laboratory FNR by less than 1%; Autopap rescreening reduced the overall laboratory FNR by 5.7%. At the same time, the false-positive rate for Autopap screening was significantly less than that of routine manual screening at the ASCUS level (4.7% vs. 5.6%; P < 0.0001). Rescreening with the Autopap system remained more sensitive than manual rescreening at the low grade squamous intraepithelial lesions threshold (FNR of 58.8% vs. 100%, respectively), although the number of cases rescreened was low. Routine manual rescreening cannot be used to calculate the FNR of primary screening. Routine rescreening is an extremely ineffective method to detect error and thereby decrease a laboratory's FNR. The Autopap system is a much more effective way of detecting errors within a laboratory and reduces the laboratory's FNR by greater than 25%.

  14. Optimization approaches to ameliorate humidity and vibration related issues using the microAeth black carbon monitor for personal exposure measurement

    PubMed Central

    Cai, Jing; Yan, Beizhan; Kinney, Patrick L.; Perzanowski, Matthew S.; Jung, Kyung-Hwa; Li, Tiantian; Xiu, Guangli; Zhang, Danian; Olivo, Cosette; Ross, James; Miller, Rachel L.; Chillrud, Steven N.

    2014-01-01

    Exposure to ambient black carbon (BC) is associated with adverse health effects. Black carbon levels display large spatial and temporal variability in many settings, such as cities and rural households where fossil fuel and biomass, respectively, are commonly burned for transportation, heat and cooking. This paper addresses the optimization of the miniaturized personal BC monitor, the microAeth® for use in epidemiology studies. To address false positive and negative peaks in real time BC concentrations resulting from changes in temperature and humidity, an inlet with a diffusion drier was developed. In addition, we developed data cleaning algorithms to address occasional false positive and negative fluctuations in BC readings related to physical vibration, due in part to both dirt accumulations in the optical inserts and degraded components. These methods were successfully used to process real-time BC data generated from a cohort of 9-10 year old children (N= 54) in NYC, who wore 1 or 2 microAeth units for six 24hr time periods. Two hour and daily BC averages after data cleaning were consistent with averaged raw data (slopes near 1 with R =0.99, p<0.001; R= 0.95, p<0.001, respectively), strongly suggesting that the false positive and negative excursions balance each other out when averaged for at least 2 hrs. Data cleaning of identified suspect events allows more confidence in the interpretation of the real-time personal monitoring data generated in environmental exposure studies, with mean percent difference <10% for 19 duplicate deployments. PMID:25558122

  15. Characterization of Focal Liver Lesions using CEUS and MRI with Liver-Specific Contrast Media: Experience of a Single Radiologic Center.

    PubMed

    Beyer, Lukas Philipp; Wassermann, Florian; Pregler, Benedikt; Michalik, Katharina; Rennert, Janine; Wiesinger, Isabel; Stroszczynski, Christian; Wiggermann, Philipp; Jung, Ernst Michael

    2017-12-01

     The purpose of this study was to compare contrast-enhanced ultrasound (CEUS), magnetic resonance imaging (MRI) using liver-specific contrast agent and a combination of both for the characterization of focal liver lesions (FLL).  83 patients with both benign and malignant liver lesions were examined using CEUS and MRI after the intravenous administration of liver-specific contrast media. All patients had inconclusive results from prior imaging examinations. Histopathological specimens could be obtained in 53 patients. Ultrasound was performed using a multi-frequency curved probe (1 - 6 MHz) after the injection of 1 - 2.4 ml ultrasound contrast media. The sensitivity, specificity, positive predictive value and negative predictive value of CEUS, MRI and a combination of both (CEUS + MRI) were compared.  The sensitivity, specificity, positive and negative predictive values regarding lesion classification were 90.9 %, 70.6 %, 92.3 % and 66.6 %, respectively, for CEUS; 90.9 %, 82.4 %, 95.2 % and 70.0 %, respectively, for MRI; and 96.9 %, 70.6 %, 92.7 % and 85.7 % respectively, for CEUS + MRI. There were no statistically significant differences. 6 malignant lesions were missed using CEUS or MRI alone (false negatives). The use of both modalities combined reduced the false-negative results to 2.  CEUS and MRI with liver-specific contrast media are very reliable and of equal informative value in the characterization of focal liver lesions. The number of false-negative results can be decreased using a combination of the two methods. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Case Reports of Aripiprazole Causing False-Positive Urine Amphetamine Drug Screens in Children.

    PubMed

    Kaplan, Justin; Shah, Pooja; Faley, Brian; Siegel, Mark E

    2015-12-01

    Urine drug screens (UDSs) are used to identify the presence of certain medications. One limitation of UDSs is the potential for false-positive results caused by cross-reactivity with other substances. Amphetamines have an extensive list of cross-reacting medications. The literature contains reports of false-positive amphetamine UDSs with multiple antidepressants and antipsychotics. We present 2 cases of presumed false-positive UDSs for amphetamines after ingestion of aripiprazole. Case 1 was a 16-month-old girl who accidently ingested 15 to 45 mg of aripiprazole. She was lethargic and ataxic at home with 1 episode of vomiting containing no identifiable tablets. She remained sluggish with periods of irritability and was admitted for observation. UDS on 2 consecutive days came back positive for amphetamines. Case 2 was of a 20-month-old girl who was brought into the hospital after accidental ingestion of an unknown quantity of her father's medications which included aripiprazole. UDS on the first day of admission came back positive only for amphetamines. Confirmatory testing with gas chromatography-mass spectrometry (GC-MS) on the blood and urine samples were also performed for both patients on presentation to detect amphetamines and were subsequently negative. Both patients returned to baseline and were discharged from the hospital. To our knowledge, these cases represent the first reports of false-positive amphetamine urine drug tests with aripiprazole. In both cases, aripiprazole was the drug with the highest likelihood of causing the positive amphetamine screen. The implications of these false-positives include the possibility of unnecessary treatment and monitoring of patients. Copyright © 2015 by the American Academy of Pediatrics.

  17. Mood-congruent true and false memory: effects of depression.

    PubMed

    Howe, Mark L; Malone, Catherine

    2011-02-01

    The Deese/Roediger-McDermott paradigm was used to investigate the effect of depression on true and false recognition. In this experiment true and false recognition was examined across positive, neutral, negative, and depression-relevant lists for individuals with and without a diagnosis of major depressive disorder. Results showed that participants with major depressive disorder falsely recognised significantly more depression-relevant words than non-depressed controls. These findings also parallel recent research using recall instead of recognition and show that there are clear mood congruence effects for depression on false memory performance. © 2011 Psychology Press, an imprint of the Taylor & Francis Group, an Informa business

  18. Precision and recall estimates for two-hybrid screens

    PubMed Central

    Huang, Hailiang; Bader, Joel S.

    2009-01-01

    Motivation: Yeast two-hybrid screens are an important method to map pairwise protein interactions. This method can generate spurious interactions (false discoveries), and true interactions can be missed (false negatives). Previously, we reported a capture–recapture estimator for bait-specific precision and recall. Here, we present an improved method that better accounts for heterogeneity in bait-specific error rates. Result: For yeast, worm and fly screens, we estimate the overall false discovery rates (FDRs) to be 9.9%, 13.2% and 17.0% and the false negative rates (FNRs) to be 51%, 42% and 28%. Bait-specific FDRs and the estimated protein degrees are then used to identify protein categories that yield more (or fewer) false positive interactions and more (or fewer) interaction partners. While membrane proteins have been suggested to have elevated FDRs, the current analysis suggests that intrinsic membrane proteins may actually have reduced FDRs. Hydrophobicity is positively correlated with decreased error rates and fewer interaction partners. These methods will be useful for future two-hybrid screens, which could use ultra-high-throughput sequencing for deeper sampling of interacting bait–prey pairs. Availability: All software (C source) and datasets are available as supplemental files and at http://www.baderzone.org under the Lesser GPL v. 3 license. Contact: joel.bader@jhu.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:19091773

  19. Sensitivity of fetal RHD screening for safe guidance of targeted anti-D immunoglobulin prophylaxis: prospective cohort study of a nationwide programme in the Netherlands.

    PubMed

    de Haas, Masja; Thurik, Florentine F; van der Ploeg, Catharina P B; Veldhuisen, Barbera; Hirschberg, Hoang; Soussan, Aicha Ait; Woortmeijer, Heleen; Abbink, Frithjofna; Page-Christiaens, Godelieve C M L; Scheffer, Peter G; Ellen van der Schoot, C

    2016-11-07

     To determine the accuracy of non-invasive fetal testing for the RHD gene in week 27 of pregnancy as part of an antenatal screening programme to restrict anti-D immunoglobulin use to women carrying a child positive for RHD DESIGN:  Prospectively monitoring of fetal RHD testing accuracy compared with serological cord blood typing on introduction of the test. Fetal RHD testing was performed with a duplex real time quantitative polymerase chain reaction, with cell-free fetal DNA isolated from 1 mL of maternal plasma The study period was between 4 July 2011 and 7 October 2012. The proportion of women participating in screening was determined.  Nationwide screening programme, the Netherlands. Tests are performed in a centralised setting.  25 789 RhD negative pregnant women.  Sensitivity, specificity, false negative rate, and false positive rate of fetal RHD testing compared with serological cord blood typing; proportion of technical failures; and compliance to the screening programme.  A fetal RHD test result and serological cord blood result were available for 25 789 pregnancies. Sensitivity for detection of fetal RHD was 99.94% (95% confidence interval 99.89% to 99.97%) and specificity was 97.74% (97.43% to 98.02%). Nine false negative results for fetal RHD testing were registered (0.03%, 95% confidence interval 0.01% to 0.06%). In two cases these were due to technical failures. False positive fetal RHD testing results were registered for 225 samples (0.87%, 0.76% to 0.99%). Weak RhD expression was shown in 22 of these cases, justifying anti-D immunoglobulin use. The negative and positive predictive values were 99.91% (95% confidence interval 99.82% to 99.95%) and 98.60% (98.40% to 98.77%), respectively. More than 98% of the women participated in the screening programme.  Fetal RHD testing in week 27 of pregnancy as part of a national antenatal screening programme is highly reliable and can be used to target both antenatal and postnatal anti-D immunoglobulin use. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. Staining for factor VIII related antigen and Ulex europaeus agglutinin I (UEA-I) in 230 tumours. An assessment of their specificity for angiosarcoma and Kaposi's sarcoma.

    PubMed

    Leader, M; Collins, M; Patel, J; Henry, K

    1986-11-01

    In this study we examined the staining reactivity of commercially available antisera to factor VIII related antigen (F VIII RAg) and Ulex europaeus agglutinin I (UEA-I) on sections from 230 formalin fixed paraffin embedded tumours. These included 196 sarcomas, 20 carcinomas and 14 angiomas. All angiomas showed positive staining for F VIII RAg; all carcinomas showed negative staining; the vasoformative areas of all angiosarcomas stained positively but only four of six angiosarcomas showed positive staining of their solid areas; of seven Kaposi's sarcomas, all showed positive staining of vessels and six showed positive staining of the spindle cell component. In the remaining 181 non-vascular sarcomas there was a false positive result in four tumours (2.2%), three of which had a history of irradiation. Pre-radiotherapy biopsies of these three tumours stained negatively with anti-F VIII RAg. UEA-I was demonstrated in all the angiomas studied, in all angiosarcomas (including the solid components) and in well-formed vessels of all Kaposi's sarcomas, but only in the spindle cell component of 3/6. However, there was an unacceptably high rate of false positive staining amongst the carcinomas and non-vascular sarcomas. In conclusion, F VIII RAg is a specific but not a sensitive marker of angiosarcomas; UEA-I is a sensitive but not a specific marker of angiosarcomas.

  1. Hog Charm II tetracycline test screening results compared with a liquid chromatography tandem mass spectrometry 10-μg/kg method.

    PubMed

    Salter, Robert; Holmes, Steven; Legg, David; Coble, Joel; George, Bruce

    2012-02-01

    Pork tissue samples that tested positive and negative by the Charm II tetracycline test screening method in the slaughter plant laboratory were tested with the modified AOAC International liquid chromatography tandem mass spectrometry (LC-MS-MS) method 995.09 to determine the predictive value of the screening method at detecting total tetracyclines at 10 μg/kg of tissue, in compliance with Russian import regulations. There were 218 presumptive-positive tetracycline samples of 4,195 randomly tested hogs. Of these screening test positive samples, 83% (182) were positive, >10 μg/kg by LC-MS-MS; 12.8% (28) were false violative, greater than limit of detection (LOD) but <10 μg/kg; and 4.2% (8) were not detected at the LC-MS-MS LOD. The 36 false-violative and not-detected samples represent 1% of the total samples screened. Twenty-seven of 30 randomly selected tetracycline screening negative samples tested below the LC-MS-MS LOD, and 3 samples tested <3 μg/kg chlortetracycline. Results indicate that the Charm II tetracycline test is effective at predicting hogs containing >10 μg/kg total tetracyclines in compliance with Russian import regulations.

  2. Developmental reversals in false memory: Effects of emotional valence and arousal.

    PubMed

    Brainerd, C J; Holliday, R E; Reyna, V F; Yang, Y; Toglia, M P

    2010-10-01

    Do the emotional valence and arousal of events distort children's memories? Do valence and arousal modulate counterintuitive age increases in false memory? We investigated those questions in children, adolescents, and adults using the Cornell/Cortland Emotion Lists, a word list pool that induces false memories and in which valence and arousal can be manipulated factorially. False memories increased with age for unpresented semantic associates of word lists, and net accuracy (the ratio of true memory to total memory) decreased with age. These surprising developmental trends were more pronounced for negatively valenced materials than for positively valenced materials, they were more pronounced for high-arousal materials than for low-arousal materials, and developmental increases in the effects of arousal were small in comparison with developmental increases in the effects of valence. These findings have ramifications for legal applications of false memory research; materials that share the emotional hallmark of crimes (events that are negatively valenced and arousing) produced the largest age increases in false memory and the largest age declines in net accuracy. Copyright 2010 Elsevier Inc. All rights reserved.

  3. Models for Threat Assessment in Networks

    DTIC Science & Technology

    2006-09-01

    Software International and Command AntiVirus . [Online]. Available: http://www.commandsoftware.com/virus/newlove.html [38] C. Ng and P. Ferrie. (2000...28 2.3 False positive trends across all population sizes for r=0.7 and m=0.1 . . . . 33 2.4 False negative trends across all population...benefits analysis is often performed to determine the list of mitigation procedures. Traditionally, risk assessment has been done in part with software

  4. Development of size-selective sampling of Bacillus anthracis surrogate spores from simulated building air intake mixtures for analysis via laser-induced breakdown spectroscopy.

    PubMed

    Gibb-Snyder, Emily; Gullett, Brian; Ryan, Shawn; Oudejans, Lukas; Touati, Abderrahmane

    2006-08-01

    Size-selective sampling of Bacillus anthracis surrogate spores from realistic, common aerosol mixtures was developed for analysis by laser-induced breakdown spectroscopy (LIBS). A two-stage impactor was found to be the preferential sampling technique for LIBS analysis because it was able to concentrate the spores in the mixtures while decreasing the collection of potentially interfering aerosols. Three common spore/aerosol scenarios were evaluated, diesel truck exhaust (to simulate a truck running outside of a building air intake), urban outdoor aerosol (to simulate common building air), and finally a protein aerosol (to simulate either an agent mixture (ricin/anthrax) or a contaminated anthrax sample). Two statistical methods, linear correlation and principal component analysis, were assessed for differentiation of surrogate spore spectra from other common aerosols. Criteria for determining percentages of false positives and false negatives via correlation analysis were evaluated. A single laser shot analysis of approximately 4 percent of the spores in a mixture of 0.75 m(3) urban outdoor air doped with approximately 1.1 x 10(5) spores resulted in a 0.04 proportion of false negatives. For that same sample volume of urban air without spores, the proportion of false positives was 0.08.

  5. The effect of information about false negative and false positive rates on people's attitudes towards colorectal cancer screening using faecal occult blood testing (FOBt).

    PubMed

    Miles, Anne; Rodrigues, Vania; Sevdalis, Nick

    2013-11-01

    To examine the impact of numeric risk information about false negative (FN) and false positive (FP) rates in faecal occult blood testing (FOBt) on attitudes towards screening. 95 people aged 45-59, living in England, read 6 hypothetical vignettes presented online about the use of FOB testing to detect bowel cancer, in which information about FN and FP rates was systematically varied. Both verbal and numeric FN risk information reduced people's interest in screening compared with no FN information. Numeric FN risk information reduced people's perceptions of screening effectiveness and lowered perceived trust in the results of screening compared with both verbal FN information and no FN information. FP information did not affect attitudes towards FOB testing. There was limited evidence that FN information reduced interest and perceptions of screening effectiveness more in educated groups. Numeric FN risk information decreased people's perceptions of screening effectiveness and trust in the results of screening but did not affect people's interest in screening anymore than verbal FN risk information. Numeric FN information could be added to patient information without affecting interest in screening, although this needs to be replicated in a larger, more representative sample. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  6. Global Sensitivity Analysis with Small Sample Sizes: Ordinary Least Squares Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Michael J.; Liu, Wei; Sivaramakrishnan, Raghu

    2016-12-21

    A new version of global sensitivity analysis is developed in this paper. This new version coupled with tools from statistics, machine learning, and optimization can devise small sample sizes that allow for the accurate ordering of sensitivity coefficients for the first 10-30 most sensitive chemical reactions in complex chemical-kinetic mechanisms, and is particularly useful for studying the chemistry in realistic devices. A key part of the paper is calibration of these small samples. Because these small sample sizes are developed for use in realistic combustion devices, the calibration is done over the ranges of conditions in such devices, with amore » test case being the operating conditions of a compression ignition engine studied earlier. Compression ignition engines operate under low-temperature combustion conditions with quite complicated chemistry making this calibration difficult, leading to the possibility of false positives and false negatives in the ordering of the reactions. So an important aspect of the paper is showing how to handle the trade-off between false positives and false negatives using ideas from the multiobjective optimization literature. The combination of the new global sensitivity method and the calibration are sample sizes a factor of approximately 10 times smaller than were available with our previous algorithm.« less

  7. High resolution melting analysis for epidermal growth factor receptor mutations in formalin-fixed paraffin-embedded tissue and plasma free DNA from non-small cell lung cancer patients.

    PubMed

    Jing, Chang-Wen; Wang, Zhuo; Cao, Hai-Xia; Ma, Rong; Wu, Jian-Zhong

    2014-01-01

    The aim of the research was to explore a cost effective, fast, easy to perform, and sensitive method for epidermal growth factor receptor (EGFR) mutation testing. High resolution melting analysis (HRM) was introduced to evaluate the efficacy of the analysis for dectecting EGFR mutations in exons 18 to 21 using formalin-fixed paraffin-embedded (FFPE) tissues and plasma free DNA from 120 patients. The total EGFR mutation rate was 37.5% (45/120) detected by direct sequencing. There were 48 mutations in 120 FFPE tissues assessed by HRM. For plasma free DNA, the EGFR mutation rate was 25.8% (31/120). The sensitivity of HRM assays in FFPE samples was 100% by HRM. There was a low false-positive mutation rate but a high false-negative rate in plasma free DNA detected by HRM. Our results show that HRM analysis has the advantage of small tumor sample need. HRM applied with plasma free DNA showed a high false-negative rate but a low false-positive rate. Further research into appropriate methods and analysis needs to be performed before HRM for plasma free DNA could be accepted as an option in diagnostic or screening settings.

  8. Evaluation of recombinant proteins of Burkholderia mallei for serodiagnosis of glanders.

    PubMed

    Pal, Vijai; Kumar, Subodh; Malik, Praveen; Rai, Ganga Prasad

    2012-08-01

    Glanders is a contagious disease caused by the Gram-negative bacillus Burkholderia mallei. The number of equine glanders outbreaks has increased steadily during the last decade. The disease must be reported to the Office International des Epizooties, Paris, France. Glanders serodiagnosis is hampered by the considerable number of false positives and negatives of the internationally prescribed tests. The major problem leading to the low sensitivity and specificity of the complement fixation test (CFT) and enzyme-linked immunosorbent assay (ELISA) has been linked to the test antigens currently used, i.e., crude preparations of whole cells. False-positive results obtained from other diagnostic tests utilizing crude antigens lead to financial losses to animal owners, and false-negative results can turn a risk into a possible threat. In this study, we report on the identification of diagnostic targets using bioinformatics tools for serodiagnosis of glanders. The identified gene sequences were cloned and expressed as recombinant proteins. The purified recombinant proteins of B. mallei were used in an indirect ELISA format for serodiagnosis of glanders. Two recombinant proteins, 0375H and 0375TH, exhibited 100% sensitivity and specificity for glanders diagnosis. The proteins also did not cross-react with sera from patients with the closely related disease melioidosis. The results of this investigation highlight the potential of recombinant 0375H and 0375TH proteins in specific and sensitive diagnosis of glanders.

  9. Evaluation of Recombinant Proteins of Burkholderia mallei for Serodiagnosis of Glanders

    PubMed Central

    Kumar, Subodh; Malik, Praveen

    2012-01-01

    Glanders is a contagious disease caused by the Gram-negative bacillus Burkholderia mallei. The number of equine glanders outbreaks has increased steadily during the last decade. The disease must be reported to the Office International des Epizooties, Paris, France. Glanders serodiagnosis is hampered by the considerable number of false positives and negatives of the internationally prescribed tests. The major problem leading to the low sensitivity and specificity of the complement fixation test (CFT) and enzyme-linked immunosorbent assay (ELISA) has been linked to the test antigens currently used, i.e., crude preparations of whole cells. False-positive results obtained from other diagnostic tests utilizing crude antigens lead to financial losses to animal owners, and false-negative results can turn a risk into a possible threat. In this study, we report on the identification of diagnostic targets using bioinformatics tools for serodiagnosis of glanders. The identified gene sequences were cloned and expressed as recombinant proteins. The purified recombinant proteins of B. mallei were used in an indirect ELISA format for serodiagnosis of glanders. Two recombinant proteins, 0375H and 0375TH, exhibited 100% sensitivity and specificity for glanders diagnosis. The proteins also did not cross-react with sera from patients with the closely related disease melioidosis. The results of this investigation highlight the potential of recombinant 0375H and 0375TH proteins in specific and sensitive diagnosis of glanders. PMID:22695165

  10. [Quality assurance of rapid on-site evaluation of CT-guided fine-needle aspiration cytology of lung nodules].

    PubMed

    Bak, Mihály; Hidvégi, Judit; Andi, Judit; Bahéry, Mária; Kovács, Eszter; Schneider, Ferenc; Kostic, Szilárd; Rényi-Vámos, Ferenc; Szőke, János; Nyári, Tibor; Gődény, Mária; Kásler, Miklós

    2013-01-06

    The methods available for the diagnosis of lung cancer include radiologic, cytologic and pathologic procedures. The aim of this study was to determine the quality assurance of CT guided fine needle aspiration cytology of lung nodules. Cytology results were rated to 4 categories (positive; suspicious; negative; not representative). All cytology reports were compared with the final histology diagnosis. A total of 128 patients underwent CT-guided percutaneous fine-needle aspiration biopsy cytology (63 males; 65 females; mean age 62.8 years). Smears were adequate in 99 cases and inadequate in 29 cases. The average diameter of the nodules was 3.28 cm. Thirty three (25.6%) of the cases were histologically verified and 2 falsely negative and 2 falsely positive cases were detected. The sensitivity and the positive predictive value were 88.8% and 88.8%, respectively. Pneumothorax developed in 7 (5.4%) cases. These results suggest that CT-guided transthoracic fine needle aspiration cytology has a high diagnostic accuracy and an acceptable complication rate. The auditing valves of the results meet the proposed threshold values.

  11. Development of a Library Search-Based Screening System for 3,4-Methylenedioxymethamphetamine in Ecstasy Tablets Using a Portable Near-Infrared Spectrometer.

    PubMed

    Tsujikawa, Kenji; Yamamuro, Tadashi; Kuwayama, Kenji; Kanamori, Tatsuyuki; Iwata, Yuko T; Miyamoto, Kazuna; Kasuya, Fumiyo; Inoue, Hiroyuki

    2016-09-01

    This is the first report on development of a library search-based screening system for 3,4-methylenedioxymethamphetamine (MDMA) in ecstasy tablets using a portable near-infrared (NIR) spectrometer. The spectrum library consisted of spectra originating from standard substances as well as mixtures of MDMA hydrochloride (MDMA-HCl) and diluents. The raw NIR spectra were mathematically pretreated, and then, a library search was performed using correlation coefficient. To enhance the discrimination ability, the wavelength used for the library search was limited. Mixtures of MDMA-HCl and diluents were used to decide criteria to judge MDMA-positive or MDMA-negative. Confiscated MDMA tablets and medicinal tablets were used for performance check of the criteria. Twenty-two of 27 MDMA tablets were truly judged as MDMA-positive. Five false-negative results may be caused by compounds not included in the library. No false-positive results were obtained for medicinal tablets. This system will be a useful tool for on-site screening of MDMA tablets. © 2016 American Academy of Forensic Sciences.

  12. Mood, motivation, and misinformation: aging and affective state influences on memory.

    PubMed

    Hess, Thomas M; Popham, Lauren E; Emery, Lisa; Elliott, Tonya

    2012-01-01

    Normative age differences in memory have typically been attributed to declines in basic cognitive and cortical mechanisms. The present study examined the degree to which dominant everyday affect might also be associated with age-related memory errors using the misinformation paradigm. Younger and older adults viewed a positive and a negative event, and then were exposed to misinformation about each event. Older adults exhibited a higher likelihood than young adults of falsely identifying misinformation as having occurred in the events. Consistent with expectations, strength of the misinformation effect was positively associated with dominant mood, and controlling for mood eliminated any age effects. Also, motivation to engage in complex cognitive activity was negatively associated with susceptibility to misinformation, and susceptibility was stronger for negative than for positive events. We argue that motivational processes underlie all of the observed effects, and that such processes are useful in understanding age differences in memory performance.

  13. Mood, motivation, and misinformation: Aging and affective state influences on memory

    PubMed Central

    Hess, Thomas M.; Popham, Lauren E.; Emery, Lisa; Elliott, Tonya

    2014-01-01

    Normative age differences in memory have typically been attributed to declines in basic cognitive and cortical mechanisms. The present study examined the degree to which dominant everyday affect might also be associated with age-related memory errors using the misinformation paradigm. Younger and older adults viewed a positive and a negative event, and then were exposed to misinformation about each event. Older adults exhibited a higher likelihood than young adults of falsely identifying misinformation as having occurred in the events. Consistent with expectations, strength of the misinformation effect was positively associated with dominant mood, and controlling for mood eliminated any age effects. Also, motivation to engage in complex cognitive activity was negatively associated with susceptibility to misinformation, and susceptibility was stronger for negative than for positive events. We argue that motivational processes underlie all of the observed effects, and that such processes are useful in understanding age differences in memory performance. PMID:22059441

  14. Incidence of tuberculous meningitis in France, 2000: a capture-recapture analysis.

    PubMed

    Cailhol, J; Che, D; Jarlier, V; Decludt, B; Robert, J

    2005-07-01

    To estimate the incidence of culture-positive and culture-negative tuberculous meningitis (TBM) in France in 2000. Capture-recapture method using two unrelated sources of data: the tuberculosis (TB) mandatory notification system (MNTB), recording patients treated by anti-tuberculosis drugs, and a survey by the National Reference Centre (NRC) for mycobacterial drug resistance, recording culture-positive TBM. Of 112 cases of TBM reported to the MNTB, 28 culture-positive and 34 culture-negative meningitis cases were validated (17 duplicates, 3 cases from outside France, 21 false notifications, and 9 lost records were excluded). The NRC recorded 31 culture-positive cases, including 21 known by the MNTB. When the capture-recapture method was applied to the reported culture-positive meningitis cases, the estimated number of meningitis cases was 41 and the incidence was 0.7 cases per million. Sensitivity was 75.6% for the NRC, 68.3% for the MNTB, and 92.7% for both systems together. When sensitivity of the MNTB for culture-positive cases was applied to culture-negative meningitis, the total estimated number of culture-negative meningitis cases was 50 and the incidence was 0.85 cases per million. TBM is underestimated in France. Capture-recapture analysis using different sources to better estimate its incidence is of great interest.

  15. Role of Urine Drug Testing in the Current Opioid Epidemic.

    PubMed

    Mahajan, Gagan

    2017-12-01

    While the evidence for urine drug testing for patients on chronic opioid therapy is weak, the guidelines created by numerous medical societies and state and federal regulatory agencies recommend that it be included as one of the tools used to monitor patients for compliance with chronic opioid therapy. To get the most comprehensive results, clinicians should order both an immunoassay screen and confirmatory urine drug test. The immunoassay screen, which can be performed as an in-office point-of-care test or as a laboratory-based test, is a cheap and convenient study to order. Limitations of an immunoassay screen, however, include having a high threshold of detectability and only providing qualitative information about a select number of drug classes. Because of these restrictions, clinicians should understand that immunoassay screens have high false-positive and false-negative rates. Despite these limitations, though, the results can assist the clinician with making preliminary treatment decisions. In comparison, a confirmatory urine drug test, which can only be performed as a laboratory-based test, has a lower threshold of detectability and provides both qualitative and quantitative information. A urine drug test's greater degree of specificity allows for a relatively low false-negative and false-positive rate in contrast to an immunoassay screen. Like any other diagnostic test, an immunoassay screen and a confirmatory urine drug test both possess limitations. Clinicians must keep this in mind when interpreting an unexpected test result and consult with their laboratory when in doubt about the meaning of the test result to avoid making erroneous decisions that negatively impact both the patient and clinician.

  16. An immunoblotting diagnostic assay for heartwater based on the immunodominant 32-kilodalton protein of Cowdria ruminantium detects false positives in field sera.

    PubMed Central

    Mahan, S M; Tebele, N; Mukwedeya, D; Semu, S; Nyathi, C B; Wassink, L A; Kelly, P J; Peter, T; Barbet, A F

    1993-01-01

    Heartwater, a major constraint to improved livestock production in Zimbabwe, threatens to invade areas which have been previously unaffected. To monitor its spread in Zimbabwe, an immunoblotting diagnostic assay based on the responses of animals to the immunodominant, conserved 32-kDa protein of Cowdria ruminantium was evaluated. In this assay, no false reactions were detected with sera known to be positive and negative, but sera from some cattle, sheep, and goats from heartwater-free areas of Zimbabwe reacted strongly with the 32-kDa protein, suggesting that either these animals had previous exposure to heartwater or they were false positives. To investigate the possibility of previous exposure to heartwater, 11 immunoblot-positive and 6 immunoblot-negative sheep from heartwater-free areas of Zimbabwe were compared regarding their susceptibilities to challenge with C. ruminantium. Prior to challenge, C. ruminantium could not be detected in any sheep by transmission to Amblyomma hebraeum ticks or by the polymerase chain reaction (PCR) conducted with plasma samples. All sheep were equally susceptible to the challenge, and infection was confirmed by brain biopsy, necropsy, PCR, and transmission of C. ruminantium to ticks. Our data suggest that the immunoblot-positive reactions of sera from heartwater-free areas were due not to previous C. ruminantium infection but rather to antigenic cross-reactivity between C. ruminantium and another agent(s) such as Ehrlichia species. In conclusion, the immunodominant 32-kDa protein is not antigenically specific to C. ruminantium and its use in serological diagnosis of heartwater requires reevaluation. Images PMID:8253974

  17. Detection and Species Determination of Malaria Parasites by PCR: Comparison with Microscopy and with ParaSight-F and ICT Malaria Pf Tests in a Clinical Environment

    PubMed Central

    Tham, Jill M.; Lee, Szu Hee; Tan, Theresa M. C.; Ting, Robert C. Y.; Kara, Ursula A. K.

    1999-01-01

    A rapid procedure for the diagnosis of malaria infections directly from dried blood spots by PCR amplification was evaluated with samples from 52 patients. Plasmodium infections were identified with a genus-specific primer set, and species differentiation between Plasmodium falciparum and Plasmodium vivax was analyzed by multiplex PCR. The PCR test with any of the three primer sets was able to detect as few as four parasites per microliter by gel electrophoresis or by nonisotopic paper hybridization chromatography. The diagnoses obtained by PCR correlated closely with those obtained by Giemsa staining except for two samples observed to have mixed P. falciparum-P. vivax infections. These were initially missed by microscopic analysis. In comparison with antigen-capture assays for P. falciparum, the PCR assays were able to detect three infections that were missed by the ParaSight-F test. The PCR test was negative for nine ParaSight-F-positive samples and one ICT Malaria Pf-positive sample, and these were confirmed to be false-positive results. The PCR thus gave no false-negative or false-positive results. Patients undergoing antimalarial therapy were also monitored by the PCR assay. Four of seven patients who were PCR positive for P. vivax at the time of discharge were later readmitted to the hospital with a recurrence of P. vivax infection. We would like to propose that PCR is a sensitive and easy method that can serve as a useful addition to microscopy for the diagnosis and the clinical monitoring of treatment of malaria. PMID:10203469

  18. 40 CFR 141.21 - Coliform sampling.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... water) with the intent that if the method they choose has an unacceptable false-positive or negative...), supplemented with 100 µg/mL of MUG. If the 18th edition is used, incubate the agar plate at 35 °C for 4 hours...

  19. 40 CFR 141.21 - Coliform sampling.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... water) with the intent that if the method they choose has an unacceptable false-positive or negative...), supplemented with 100 µg/mL of MUG. If the 18th edition is used, incubate the agar plate at 35 °C for 4 hours...

  20. 40 CFR 141.21 - Coliform sampling.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... water) with the intent that if the method they choose has an unacceptable false-positive or negative...), supplemented with 100 µg/mL of MUG. If the 18th edition is used, incubate the agar plate at 35 °C for 4 hours...

  1. Performance of acidified 14C-urea capsule breath test during pantoprazole and ranitidine treatment.

    PubMed

    Oztürk, Emel; Yeşilova, Zeki; Ilgan, Seyfettin; Ozgüven, Mehmet; Dağalp, Kemal

    2009-07-01

    Urea breath test (UBT) results could be false negative in patients taking antisecretory drugs. This effect would be prevented by citric acid administration during UBT. We prospectively investigated whether acidified 14C-urea capsule prevents false negative UBT results in patients taking antisecretory drugs and show interference with the duration of medications. Sixty Helicobacter pylori positive patients were included. Pantoprazole (40 mg/day) was given to 27 patients for 28 days and ranitidine (300 mg. o.d.) to 33 patients for 60 days. Urea breath tests were repeated on days 14 and 28 in both groups and on day 60 in the ranitidine group. The baseline mean breath counts of two groups did not show any significant difference. Pantoprazole led to a significant decrease in mean breath counts on day 14 (P < 0.005). Six of 27 and 3 of 25 patients taking pantoprazole developed negative or equivocal UBT results on days 14 and 28, respectively. Two of 32, 2 of 32 and 3 of 21 patients taking ranitidine developed negative or equivocal UBT results on days 14, 28 and 60, respectively. The use of acidified 14C-urea capsule did not prevent false negative UBT results in patients taking pantoprazole and ranitidine, and the duration of medication does not affect the test results.

  2. Is it necessary to remove the seminal vesicles completely at radical prostatectomy? decision curve analysis of European Society of Urologic Oncology criteria.

    PubMed

    Secin, Fernando P; Bianco, Fernando J; Cronin, Angel; Eastham, James A; Scardino, Peter T; Guillonneau, Bertrand; Vickers, Andrew J

    2009-02-01

    A publication on behalf of the European Society of Urological Oncology questioned the need for removing the seminal vesicles during radical prostatectomy in patients with prostate specific antigen less than 10 ng/ml except when biopsy Gleason score is greater than 6 or there are greater than 50% positive biopsy cores. We applied the European Society of Urological Oncology algorithm to an independent data set to determine its predictive value. Data on 1,406 men who underwent radical prostatectomy and seminal vesicle removal between 1998 and 2004 were analyzed. Patients with and without seminal vesicle invasion were classified as positive or negative according to the European Society of Urological Oncology algorithm. Of 90 cases with seminal vesicle invasion 81 (6.4%) were positive for 90% sensitivity, while 656 of 1,316 without seminal vesicle invasion were negative for 50% specificity. The negative predictive value was 98.6%. In decision analytic terms if the loss in health when seminal vesicles are invaded and not completely removed is considered at least 75 times greater than when removing them unnecessarily, the algorithm proposed by the European Society of Urological Oncology should not be used. Whether to use the European Society of Urological Oncology algorithm depends not only on its accuracy, but also on the relative clinical consequences of false-positive and false-negative results. Our threshold of 75 is an intermediate value that is difficult to interpret, given uncertainties about the benefit of seminal vesicle sparing and harm associated with untreated seminal vesicle invasion. We recommend more formal decision analysis to determine the clinical value of the European Society of Urological Oncology algorithm.

  3. Colonic polyps: application value of computer-aided detection in computed tomographic colonography.

    PubMed

    Zhang, Hui-Mao; Guo, Wei; Liu, Gui-Feng; An, Dong-Hong; Gao, Shuo-Hui; Sun, Li-Bo; Yang, Hai-Shan

    2011-02-01

    Colonic polyps are frequently encountered in clinics. Computed tomographic colonography (CTC), as a painless and quick detection, has high values in clinics. In this study, we evaluated the application value of computer-aided detection (CAD) in CTC detection of colonic polyps in the Chinese population. CTC was performed with a GE 64-row multidetector computed tomography (MDCT) scanner. Data of 50 CTC patients (39 patients positive for at least one polyp of ≥ 0.5 cm in size and the other 11 patients negative by endoscopic detection) were retrospectively reviewed first without computer-aided detection (CAD) and then with CAD by four radiologists (two were experienced and another two inexperienced) blinded to colonoscopy findings. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of detected colonic polyps, as well as the areas under the ROC curves (Az value) with and without CAD were calculated. CAD increased the overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the colonic polyps detected by experienced and inexperienced readers. The sensitivity in detecting small polyps (5 - 9 mm) with CAD in experienced and inexperienced readers increased from 82% and 44% to 93% and 82%, respectively (P > 0.05 and P < 0.001). With the use of CAD, the overall false positive rate and false negative rate for the detection of polyps by experienced and inexperienced readers decreased in different degrees. Among 13 sessile polyps not detected by CAD, two were ≥ 1.0 cm, eleven were 5 - 9 mm in diameter, and nine were flat-shaped lesions. The application of CAD in combination with CTC can increase the ability to detect colonic polyps, particularly for inexperienced readers. However, CAD is of limited value for the detection of flat polyps.

  4. The role of ethics in shale gas policies.

    PubMed

    de Melo-Martín, Inmaculada; Hays, Jake; Finkel, Madelon L

    2014-02-01

    The United States has experienced a boom in natural gas production due to recent technological innovations that have enabled natural gas to be produced from unconventional sources, such as shale. There has been much discussion about the costs and benefits of developing shale gas among scientists, policy makers, and the general public. The debate has typically revolved around potential gains in economics, employment, energy independence, and national security as well as potential harms to the environment, the climate, and public health. In the face of scientific uncertainty, national and international governments must make decisions on how to proceed. So far, the results have been varied, with some governments banning the process, others enacting moratoria until it is better understood, and others explicitly sanctioning shale gas development. These policies reflect legislature's preferences to avoid false negative errors or false positive ones. Here we argue that policy makers have a prima facie duty to minimize false negatives based on three considerations: (1) protection from serious harm generally takes precedence over the enhancement of welfare; (2) minimizing false negatives in this case is more respectful to people's autonomy; and (3) alternative solutions exist that may provide many of the same benefits while minimizing many of the harms. © 2013.

  5. Development and first evaluation of a novel multiplex real-time PCR on whole blood samples for rapid pathogen identification in critically ill patients with sepsis.

    PubMed

    van de Groep, Kirsten; Bos, Martine P; Savelkoul, Paul H M; Rubenjan, Anna; Gazenbeek, Christel; Melchers, Willem J G; van der Poll, Tom; Juffermans, Nicole P; Ong, David S Y; Bonten, Marc J M; Cremer, Olaf L

    2018-04-26

    Molecular tests may enable early adjustment of antimicrobial therapy and be complementary to blood culture (BC) which has imperfect sensitivity in critically ill patients. We evaluated a novel multiplex real-time PCR assay to diagnose bloodstream pathogens directly in whole blood samples (BSI-PCR). BSI-PCR included 11 species- and four genus-specific PCRs, a molecular Gram-stain PCR, and two antibiotic resistance markers. We collected 5 mL blood from critically ill patients simultaneously with clinically indicated BC. Microbial DNA was isolated using the Polaris method followed by automated DNA extraction. Sensitivity and specificity were calculated using BC as reference. BSI-PCR was evaluated in 347 BC-positive samples (representing up to 50 instances of each pathogen covered by the test) and 200 BC-negative samples. Bacterial species-specific PCR sensitivities ranged from 65 to 100%. Sensitivity was 26% for the Gram-positive PCR, 32% for the Gram-negative PCR, and ranged 0 to 7% for yeast PCRs. Yeast detection was improved to 40% in a smaller set-up. There was no overall association between BSI-PCR sensitivity and time-to-positivity of BC (which was highly variable), yet Ct-values were lower for true-positive versus false-positive PCR results. False-positive results were observed in 84 (4%) of the 2200 species-specific PCRs in 200 culture-negative samples, and ranged from 0 to 6% for generic PCRs. Sensitivity of BSI-PCR was promising for individual bacterial pathogens, but still insufficient for yeasts and generic PCRs. Further development of BSI-PCR will focus on improving sensitivity by increasing input volumes and on subsequent implementation as a bedside test.

  6. Is a fecal occult blood test a useful tool for judging whether to perform capsule endoscopy in low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy?

    PubMed

    Endo, Hiroki; Kato, Takayuki; Sakai, Eiji; Taniguchi, Leo; Arimoto, Jun; Kawamura, Harunobu; Higurashi, Takuma; Ohkubo, Hidenori; Nonaka, Takashi; Taguri, Masataka; Inamori, Masahiko; Yamanaka, Takeharu; Sakaguchi, Takashi; Hata, Yasuo; Nagase, Hajime; Nakajima, Atsushi

    2017-02-01

    Aspirin use is reportedly not to be associated with fecal immunochemical occult blood test (FIT) false-positive results for the detection of colorectal cancer. The need for additional small bowel exploration in FIT-positive, low-dose aspirin users with a negative colonoscopy is controversial. The aim of this study was to assess the ability of FIT to judge whether capsule endoscopy (CE) should be performed in low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy findings by comparing FIT results with CE findings. A total of 264 consecutive low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy who were scheduled to undergo CE at five hospitals in Japan were enrolled. Patients had been offered FIT prior to the CE. The association between the FIT results and the CE findings was then assessed. One hundred and fifty-seven patients were included in the final analysis. Eighty-four patients (53.5 %) had positive FIT results. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of positive FIT results for small bowel ulcers were 0.56, 0.47, 0.30, and 0.73, respectively. Furthermore, the NPV of positive FIT results for severe small bowel injury (Lewis score ≥790) was markedly high (0.90). When the analysis was performed only in low-dose aspirin users with anemia, the sensitivity of the positive FIT results was notably improved (0.72). Small bowel evaluation using CE is not recommended for FIT-negative, low-dose aspirin users. However, small bowel evaluation using CE should be considered in both FIT-positive and anemic low-dose aspirin users.

  7. Integrated imaging using MRI and 123I metaiodobenzylguanidine scintigraphy to improve sensitivity and specificity in the diagnosis of pediatric neuroblastoma.

    PubMed

    Pfluger, Thomas; Schmied, Christoph; Porn, Ute; Leinsinger, Gerda; Vollmar, Christian; Dresel, Stefan; Schmid, Irene; Hahn, Klaus

    2003-10-01

    The objectives of this study were to compare MRI and iodine-123 ((123)I) metaiodobenzylguanidine (MIBG) scintigraphy in the detection of neuroblastoma lesions in pediatric patients and to assess the additional value of combined imaging. Fifty MRI and 50 (123)I MIBG examinations (mean interval, 6.4 days) were analyzed retrospectively with regard to suspected or proven neuroblastoma lesions (n = 193) in 28 patients. MRI and MIBG scans were reviewed by two independent observers each. Separate and combined analyses of MRI and MIBG scintigraphy were compared with clinical and histologic findings. With regard to the diagnosis of neuroblastoma lesion, MIBG scintigraphy, MRI, and combined analysis showed a sensitivity of 69%, 86%, and 99% and a specificity of 85%, 77%, and 95%, respectively. On MRI, 15 false-positive findings were recorded: posttherapeutic reactive changes (n = 10), benign adrenal tumors (n = 3), and enlarged lymph nodes (n = 2). On MIBG scintigraphy, 10 false-positive findings occurred: ganglioneuromas (n = 2), benign liver tumors (n = 2), and physiologic uptake (n = 6). Thirteen neuroblastoma metastases and two residual masses under treatment with chemotherapy were judged to be false-negative findings on MRI. Two primary or residual neuroblastomas and one orbital metastasis were misinterpreted as Wilms' tumor, reactive changes after surgery, and rhabdomyosarcoma on MRI. Thirty-two bone metastases, six other neuroblastoma metastases, and one adrenal neuroblastoma showed no MIBG uptake. On combined imaging, one false-negative (bone metastasis) and three false-positive (two ganglioneuromas and one pheochromocytoma) findings remained. In the assessment of neuroblastoma lesions in pediatric patients, MRI showed a higher sensitivity and MIBG scintigraphy a higher specificity. However, integrated imaging showed an increase in both sensitivity and specificity.

  8. The use of a differential fluorescent staining method to detect bacteriuria.

    PubMed

    Ciancaglini, Ettore; Fazii, Paolo; Sforza, Giuseppe Riario

    2004-01-01

    This report describes a differential staining method which distinguishes gram-positive from gram-negative bacteria in fluorescence. Gram-positive bacteria appear yellow and gram-negative bacteria appear green. The method is based on two fluorochromes, one acting in the wavelength of red, i.e. the acridine orange, and another acting in the wavelength of green, i.e. the fluorescein, which together form a red/ green system. In this report we compared the accuracy of the differential fluorescent staining method and the Gram stain in screening for bacteriuria, as detected by conventional cultures. A total of 1487 urine samples were tested. 289 cultures were positive. 237 specimens grew a single organism at 10(5) and 10(4) CFU/ml. 224 smears were detected by the differential fluorescent staining method and 162 were detected by Gram stain. 1198 samples failed to grow organisms at 10(5) and 10(4) CFU/ml. 107 smears were falsely positive by the fluorescent staining procedure and 289 were falsely positive by the Gram stain. On the basis of the culture results, the sensitivity of the differential fluorescent staining method was 94.5% and that of the Gram stain 68.3%. The specificity of the fluorescent staining procedure was 91.6% and that of the Gram stain 75.8%. The positive predictive value and the negative predictive value of the fluorescent staining method were 67.6% and 98.8%, respectively. Those of the Gram stain were 35.9% and 92.3%, respectively. A wide range of microbiological and chemical techniques are available to identify bacteria in urine. This fluorescent staining method represents a simple, rapid, reliable method with low-running costs. The main advantage of this technique is that it enables the microbiologist to exclude the presence of bacteria in the urine within a short time after specimen receipt and to eliminate a large number of specimens for culture with significant cost saving. Another advantage of the method is that it allows to distinguish gram-positive from gram-negative bacteria in positive slides on the same day the sample is obtained. The stained smears were easily interpreted, even when the bacterial counts in the specimen were low.

  9. A rapid chemiluminescent slot blot immunoassay for the detection and quantification of Clostridium botulinum neurotoxin type E, in cultures.

    PubMed

    Cadieux, Brigitte; Blanchfield, Burke; Smith, James P; Austin, John W

    2005-05-01

    A simple, rapid, cost-effective in vitro slot blot immunoassay was developed for the detection and quantification of botulinum neurotoxin type E (BoNT/E) in cultures. Culture supernatants of 36 strains of clostridia, including 12 strains of Clostridium botulinum type E, 12 strains of other C. botulinum neurotoxin serotypes, and 12 strains of other clostridial species were tested. Samples containing BoNT/E were detected using affinity-purified polyclonal rabbit antisera prepared against BoNT/E with subsequent detection of secondary antibodies using chemiluminescence. All strains of C. botulinum type E tested positive, while all non C. botulinum type E strains tested negative. The sensitivity of the slot blot immunoassay for detection of BoNT/E was approximately four mouse lethal doses (MLD). The intensity of chemiluminescence was directly correlated with the concentration of BoNT/E up to 128 MLD, allowing quantification of BoNT/E between 4 and 128 MLD. The slot blot immunoassay was compared to the mouse bioassay for detection of BoNT/E using cultures derived from fish samples inoculated with C. botulinum type E, and cultures derived from naturally contaminated environmental samples. A total of 120 primary enrichment cultures derived from fish samples, of which 103 were inoculated with C. botulinum type E, and 17 were uninoculated controls, were assayed. Of the 103 primary enrichment cultures derived from inoculated fish samples, all were positive by mouse bioassay, while 94 were also positive by slot blot immunoassay, resulting in a 7.5% false-negative rate. All 17 primary enrichment cultures derived from the uninoculated fish samples were negative by both mouse bioassay and slot blot immunoassay. A total of twenty-six primary enrichment cultures derived from environmental samples were tested by mouse bioassay and slot blot immunoassay. Of 13 primary enrichment cultures positive by mouse bioassay, 12 were also positive by slot blot immunoassay, resulting in a 3.8% false-negative rate. All 13 primary enrichment cultures that tested negative by mouse bioassay also tested negative by slot blot immunoassay. The slot blot immunoassay could be used routinely as a positive screen for BoNT/E in primary enrichment cultures, and could be used as a replacement for the mouse bioassay for pure cultures.

  10. Insensitivity of the "Romberg test of standing balance on firm and compliant support surfaces" to the results of caloric and VEMP tests.

    PubMed

    Jacobson, Gary P; McCaslin, Devin L; Piker, Erin G; Gruenwald, Jill; Grantham, Sarah; Tegel, Lauren

    2011-01-01

    The objective of this study was to assess the sensitivity, specificity, and positive and negative predictive value of the Romberg Test of Standing Balance on Firm and Compliant Support Surfaces (RTSBFCSS) for the identification of patients with vestibular system impairments affecting the horizontal semicircular canal, saccule, and/or inferior and superior vestibular nerves. The RTSBFCSS was developed for the National Health and Nutrition Examination Survey (NHANES) and was used recently to estimate the numbers of individuals aged 40 yr or older with vestibular system impairments among the general population of the United States. A retrospective analysis of the medical records of 103 consecutive patients aged 40 yr or older (mean age 59 ± 12 yr, 71 females) who had undergone vestibular assessment at the Balance Disorders Clinic at the Vanderbilt University School of Medicine. Patients with complete electro- or videonystagmography testing, cervical vestibular evoked myogenic potential (cVEMP) testing, and the RTSBFCSS screening test were included in the analysis. A series of 2 × 2 tables were created that represented the number of "true positives," "true negatives," "false positives," and "false negatives" of the RTSBFCSS under conditions where the caloric test was abnormal and then separately where the cVEMP test was abnormal. The data were analyzed in a manner such that sensitivity, specificity, and both positive and negative predictive value of the RTSBFCSS could be calculated. When the caloric test was used as the criterion standard and the subject selection criteria in the NHANES study were used (i.e., subjects who were able to maintain postural stability for trials 1-3 of the RTSBFCSS; N = 45), the sensitivity and specificity of the RTSBFCSS to impairment of the horizontal semicircular canal or superior vestibular nerve were 55% and 64%, respectively, yielding positive and negative predictive values of 55% and 64%, respectively. When all patients aged 40 yr or older were evaluated (N = 103), the sensitivity and specificity were 61% and 58%, respectively, yielding positive and negative predictive values of 39% and 78%, respectively. Using the cVEMP test as the criterion standard for the detection of impairment affecting the saccule and/or inferior vestibular nerve did not improve the performance criteria of the NHANES screening measure. The RTSBFCSS should not be used as a screening measure for vestibular impairment.

  11. How pH, Temperature, and Time of Incubation Affect False-Positive Responses and Uncertainty of the LAL Gel-Clot Test.

    PubMed

    Lourenço, Felipe Rebello; Botelho, Túlia De Souza; Pinto, Terezinha De Jesus Andreoli

    2012-01-01

    The limulus amebocyte lysate (LAL) test is the simplest and most widely used procedure for detection of endotoxin in parenteral drugs. The LAL test demands optimal pH, ionic strength, temperature, and time of incubation. Slight changes in these parameters may increase the frequency of false-positive responses and the estimated uncertainty of the LAL test. The aim of this paper is to evaluate how changes in the pH, temperature, and time of incubation affect the occurrence of false-positive responses in the LAL test. LAL tests were performed in nominal conditions (37 °C, 60 min, and pH 7) and in different conditions of temperature (36 °C and 38 °C), time of incubation (58 and 62 min), and pH (6 and 8). Slight differences in pH increase the frequency of false-positive responses 5-fold (relative risk 5.0), resulting in an estimated of uncertainty 7.6%. Temperature and time of incubation affect the LAL test less, showing relative risks of 1.5 and 1.0, respectively. Estimated uncertainties in 36 °C or 38 °C temperatures and 58 or 62 min of incubation were found to be 2.0% and 1.0%, respectively. Simultaneous differences in these parameters significantly increase the frequency of false-positive responses. The limulus amebocyte lysate (LAL) gel-clot test is a simple test for detection of endotoxin from Gram-negative bacteria. The test is based on a gel formation when a certain amount of endotoxin is present; it is a pass/fail test. The LAL test requires optimal pH, ionic strength, temperature, and time of incubation. Slight difference in these parameters may increase the frequency of false-positive responses. The aim of this paper is to evaluate how changes in the pH, temperature, and time of incubation affect the occurrence of false-positive responses in the LAL test. We find that slight differences in pH increase the frequency of false-positive responses 5-fold. Temperature and time of incubation affect the LAL test less. Simultaneous differences in these parameters significantly increase the frequency of false-positive responses.

  12. False alarms and incorrect rejections in an information security center: correlation with the frequency of incidents.

    PubMed

    Bruno, Thiers; Abrahão, Julia

    2012-01-01

    This study examines the actions taken by operators aimed at preventing and combating information security incidents at a banking organization. The work utilizes the theoretical framework of ergonomics and cognitive psychology. The method is workplace ergonomic analysis. Its focus is directed towards examining the cognitive dimension of the work environment with special attention to the occurrence of correlations between variability in incident frequency and the results of sign detection actions. It categorizes 45,142 operator decisions according to the theory of signal detection (Sternberg, 2000). It analyzes the correlation between incident proportions (indirectly associated with the cognitive efforts demanded from the operator) and operator decisions. The study demonstrated the existence of a positive correlation between incident proportions and false positive decisions (false alarms). However, this correlation could not be observed in relation to decisions of the false-negative type (incorrect rejection).

  13. [Pharmacovigilance center --internal medicine interactions: A useful diagnostic tool].

    PubMed

    Rochoy, M; Gautier, S; Bordet, R; Caron, J; Launay, D; Hachulla, E; Hatron, P-Y; Lambert, M

    2015-08-01

    Patients hospitalized in internal medicine often have unexplained clinical symptoms for which a drug origin can be considered. The prevalence of patients hospitalized for iatrogenic is estimated between 4-22%. We wanted to evaluate the diagnostic value of the regional center of pharmacovigilance to identify or confirm an iatrogenic disease in the department of internal medicine of Lille and characterize factors associated with drug-related side effect. This is a single-center prospective diagnostic study. We included all subsequent requests from the department of internal medicine with the Nord-Pas-de-Calais regional pharmacovigilance center between 2010 and 2012. The opinion of the regional pharmacovigilance centre was held on the record of the adverse drug reaction in the national pharmacovigilance database and analyzed according to the conclusion of iatrogenic used by clinicians in internal medicine (reference diagnosis) with a follow-up to June 2013. The variables relating to the patient, medication and adverse events were analyzed by binary logistic regression. We analyzed 160 contacts: 118 concordant cases, 38 false-positives (drug-related side effect retained by the regional pharmacovigilance center only), 4 false negatives. Registration in the national pharmacovigilance database had a sensitivity of 96% (95% CI [0.92 to 0.99]), a specificity of 46% (95% CI [0.38 to 0.53]), a value positive predictive of 69% (95% CI [0.62 to 0.76]), a negative predictive value of 89% (95% CI [0.84 to 0.94]) and a negative likelihood ratio of 0.1. False-positive had chronological and semiological accountabilities questionable (adjusted RR=2.1, 95% CI [1.2 to 2.8]). In our study, the regional pharmacovigilance center confirms the clinician's suspicion of drug-related side effects and helps to exclude drug-induced with a high negative predictive value. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  14. Diagnostic and prognostic value of additional SPECT/CT in sentinel lymph node mapping in breast cancer patients.

    PubMed

    Stanzel, Susanne; Pernthaler, Birgit; Schwarz, Thomas; Bjelic-Radisic, Vesna; Kerschbaumer, Stefan; Aigner, Reingard M

    2018-06-01

    of the study was to demonstrate the diagnostic and prognostic value of SPECT/CT in sentinel lymph node mapping (SLNM) in patients with invasive breast cancer. 114 patients with invasive breast cancer with clinically negative lymph nodes were included in this retrospective study as they were referred for SLNM with 99m Tc-nanocolloid. Planar image acquisition was accomplished in a one-day or two-day protocol depending on the schedule of the surgical procedure. Low dose SPECT/CT was performed after the planar images. The sentinel lymph node biopsy (SLNB) was considered false negative if a primary recurrence developed within 12 months after SLNB in the axilla from which a tumor-free SLN had been removed. Between December 2009 and December 2011, 114 patients (pts.) underwent SLNM with additional SPECT/CT. Planar imaging identified in 109 pts. 139 SLNs, which were tumor-positive in 42 nodes (n = 41 pts.). SPECT/CT identified in 81 pts. 151 additional SLNs, of which 19 were tumor-positive and led to therapy change (axillary lymph node dissection) in 11 pts. (9.6 %). Of overall 61 tumor-positive SLNs (n = 52 pts.) SPECT/CT detected all, whereas planar imaging detected only 42 of 61 ( P < 0.0001). No patient had lymph node metastasis within 12 months after SLNB in the axilla from which a tumor-free SLN had been removed resulting in a false-negative rate of 0 %. The local relapse rate was 1.8 % leading to a 4-year disease-free survival rate of 90 %. Among patients with breast cancer, the use of SPECT/CT-aided SLNM correlated due to a better anatomical localization and identification of planar not visible SLNs with a higher detection rate of SLNs. This led to therapeutic consequences and an excellent false-negative and 4-year disease-free survival rate. Schattauer GmbH.

  15. 49 CFR 40.149 - May the MRO change a verified drug test result?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false May the MRO change a verified drug test result? 40... § 40.149 May the MRO change a verified drug test result? (a) As the MRO, you may change a verified test... positive. You would change X's test result from positive to negative and contact Y to conduct a...

  16. Decision Making for Borderline Cases in Pass/Fail Clinical Anatomy Courses: The Practical Value of the Standard Error of Measurement and Likelihood Ratio in a Diagnostic Test

    ERIC Educational Resources Information Center

    Severo, Milton; Silva-Pereira, Fernanda; Ferreira, Maria Amelia

    2013-01-01

    Several studies have shown that the standard error of measurement (SEM) can be used as an additional “safety net” to reduce the frequency of false-positive or false-negative student grading classifications. Practical examinations in clinical anatomy are often used as diagnostic tests to admit students to course final examinations. The aim of this…

  17. Comparison of the diuretic renogram and the pressure perfusion study in children

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kass, E.J.; Majd, M.; Belman, A.B.

    1985-07-01

    The authors evaluated 42 hydronephrotic kidneys with diuretic renography and pressure perfusion studies to diagnose or exclude the presence of obstruction. Both studies were highly accurate but a small number of false positive and false negative studies were observed with each testing modality. The advantages, disadvantages and potential sources of inaccuracy of each study are discussed, and a protocol for the evaluation of hydronephrosis incorporating both studies is proposed.

  18. [False positive result in mammography and its association with the presence of obesity: a case-control study].

    PubMed

    Castro-Ibarra, Marisela; Menchaca-Díaz, Rufino; Cabrales-Ruvalcaba, J Jesús; Luna-V Gómez, Rosa Alicia

    2016-01-01

    To analyze the association between a false positive result in mammography and obesity, inside the breast cancer early detection program in women affiliated to the Institute of Security and Social Services for Government and Municipality workers of the State of Baja California (ISSSTECALI). A case-control, retrospective study was done in women affiliated to ISSSTECALI to whom a mammography was performed between 2009 and 2012. Women with a false positive result in mammography were included as cases. Controls were women with a true negative result in mammography. Three controls were randomly selected for each case. Obesity was established with the body mass index (BMI) consigned in the woman's clinical file. Age and estrogen replacement therapy were included as co-variables. Seventy nine cases were identified and 237 controls were included. Obesity was observed in 54.4% of cases and in 41.3% of controls (odds ratio: 1.69; 95% confidence interval for odds ratio: 1.01-2.82; p value: 0.043). A logistic regression model including covariables maintained the observed association (p = 0.044). No association was found with analyzed co-variables. A false positive result in mammography was associated with the presence of obesity.

  19. Visual field progression in glaucoma: what is the specificity of the Guided Progression Analysis?

    PubMed

    Artes, Paul H; O'Leary, Neil; Nicolela, Marcelo T; Chauhan, Balwantray C; Crabb, David P

    2014-10-01

    To estimate the specificity of the Guided Progression Analysis (GPA) (Carl Zeiss Meditec, Dublin, CA) in individual patients with glaucoma. Observational cohort study. Thirty patients with open-angle glaucoma. In 30 patients with open-angle glaucoma, 1 eye (median mean deviation [MD], -2.5 decibels [dB]; interquartile range, -4.4 to -1.3 dB) was tested 12 times over 3 months (Humphrey Field Analyzer, Carl Zeiss Meditec; SITA Standard, 24-2). "Possible progression" and "likely progression" were determined with the GPA. These analyses were repeated after the order of the tests had been randomly rearranged (1000 unique permutations). Rate of false-positive alerts of "possible progression" and "likely progression" with the GPA. On average, the specificity of the GPA "likely progression" alert was high-for the entire sample, the mean rate of false-positive alerts after 10 follow-up tests was 2.6%. With "possible progression," the specificity was considerably lower (false-positive rate, 18.5%). Most important, the cumulative rate of false-positive alerts varied substantially among patients, from <1% to 80% with "possible progression" and from <0.1% to 20% with "likely progression." Factors associated with false-positive alerts were visual field variability (standard deviation of MD, Spearman's rho = 0.41, P<0.001) and the reliability indices (proportion of false-positive and false-negative responses, fixation losses, rho>0.31, P≤0.10). On average, progression criteria currently used in the GPA have high specificity, but some patients are more likely to show false-positive alerts than others. This is a natural consequence of population-based change criteria and may not matter in clinical trials and studies in which large groups of patients are compared. However, it must be considered when the GPA is used in clinical practice where specificity needs to be controlled for individual patients. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. Cumulative False-Positive QuantiFERON-TB Interferon-γ Release Assay Results.

    PubMed

    Gamsky, Thomas E; Lum, Thomas; Hung-Fan, Melody; Green, Jon A

    2016-05-01

    Despite reports of unreliability, the QuantiFERON-TB interferon-γ release assay is increasingly used for the annual screening of individuals at risk for latent tuberculosis. Continued use of the QuantiFERON-TB assay suggests the need for more definitive evidence of its reproducibility and accuracy. To examine reproducibility and the accumulation of false-positive test results when the QuantiFERON-TB is repeated annually and to examine the validity of confirming positive test results with the performance of a second QuantiFERON-TB. We performed a retrospective, longitudinal evaluation of results from serial screening of a cohort of emergency responders from 2001 to 2013. Results of tuberculin tests and QuantiFERON-TB tests performed annually as part of a mandated first responder examination were retroactively reviewed. In this population, positive results occurred in new individuals each year. QuantiFERON-TB results were positive in 80 of 557 tuberculin test-negative individuals examined annually for a maximum of 7 years. Only 10 individuals with initially positive results remained positive when the test was repeated the next year, and 9 of these 10 were QuantiFERON-TB-negative within 3 years. The number of individuals with a positive result increased annually, and, after 7 years, 32 (27.4%) of 117 people had a positive result. When viewed in the context of the extensive literature documenting unreliable QuantiFERON-TB test performance, our findings of frequent, cumulative, sporadic, and irreproducible positive results support discontinuing the use of the QuantiFERON-TB assay for the diagnosis of latent tuberculosis in low-risk populations.

  1. Sensitivity and Specificity of Interictal EEG-fMRI for Detecting the Ictal Onset Zone at Different Statistical Thresholds

    PubMed Central

    Tousseyn, Simon; Dupont, Patrick; Goffin, Karolien; Sunaert, Stefan; Van Paesschen, Wim

    2014-01-01

    There is currently a lack of knowledge about electroencephalography (EEG)-functional magnetic resonance imaging (fMRI) specificity. Our aim was to define sensitivity and specificity of blood oxygen level dependent (BOLD) responses to interictal epileptic spikes during EEG-fMRI for detecting the ictal onset zone (IOZ). We studied 21 refractory focal epilepsy patients who had a well-defined IOZ after a full presurgical evaluation and interictal spikes during EEG-fMRI. Areas of spike-related BOLD changes overlapping the IOZ in patients were considered as true positives; if no overlap was found, they were treated as false-negatives. Matched healthy case-controls had undergone similar EEG-fMRI in order to determine true-negative and false-positive fractions. The spike-related regressor of the patient was used in the design matrix of the healthy case-control. Suprathreshold BOLD changes in the brain of controls were considered as false positives, absence of these changes as true negatives. Sensitivity and specificity were calculated for different statistical thresholds at the voxel level combined with different cluster size thresholds and represented in receiver operating characteristic (ROC)-curves. Additionally, we calculated the ROC-curves based on the cluster containing the maximal significant activation. We achieved a combination of 100% specificity and 62% sensitivity, using a Z-threshold in the interval 3.4–3.5 and cluster size threshold of 350 voxels. We could obtain higher sensitivity at the expense of specificity. Similar performance was found when using the cluster containing the maximal significant activation. Our data provide a guideline for different EEG-fMRI settings with their respective sensitivity and specificity for detecting the IOZ. The unique cluster containing the maximal significant BOLD activation was a sensitive and specific marker of the IOZ. PMID:25101049

  2. False Memory for Trauma-Related DRM Lists in Adolescents and Adults with Histories of Child Sexual Abuse

    PubMed Central

    Goodman, Gail S.; Ogle, Christin M.; Block, Stephanie D.; Harris, LaTonya S.; Larson, Rakel P.; Augusti, Else-Marie; Cho, Young Il; Beber, Jonathan; Timmer, Susan; Urquiza, Anthony

    2014-01-01

    The purpose of the present research was to examine Deese-Roediger-McDermott (DRM) false memory for trauma-related and nontrauma-related lists in adolescents and adults with and without documented histories of child sexual abuse (CSA). Individual differences in psychopathology and adult attachment were also explored. Participants were administered free recall and recognition tests after hearing CSA, negative, neutral, and positive DRM lists. In free recall, CSA and negative lists produced the most false memory. In sharp contrast, for recognition, CSA lists enjoyed the highest d’ scores. CSA-group adolescents who evinced greater PTSD symptoms had higher rates of false memory compared to: 1) nonCSA-group adolescents with higher PTSD symptom scores (free recall), and 2) CSA-group adolescents with lower PTSD symptom scores (recognition). Regression analyses revealed that individuals with higher PTSD scores and greater fearful-avoidant attachment tendencies showed less proficient memory monitoring for CSA lists. Implications for trauma and memory development and for translational research are discussed. PMID:23786687

  3. Utility of minimal preparation ct colonography in detecting colorectal cancer in elderly and frail patients.

    PubMed

    Meiklejohn, D J; Ridley, L J; Ngu, M C; Cowlishaw, J L; Duller, A; Ridley, W

    2018-06-11

    Colorectal cancers result in substantial morbidity and mortality to Australian society each year. The usual investigation for bowel malignancyis optical colonoscopy (OC), withcomputed tomographic colonography (CTC) used as an alternative investigation. The catharsis and colon insufflation associated with these investigations pose a higher risk in the elderly and frail. Risks include perforation, serum electrolyte disturbance, and anaesthesia/sedation risks.Minimal preparation computed tomographic colonography (MPCTC) eliminates these risks. This paper audits a 6-year period ofMPCTC in an Australian tertiary referral hospital. 145 patients underwent MPCTC during the study period. There were 7 true positives, 2 false positives and 2 false negatives. Analysis of this population indicates a sensitivity of 0.78 (95% CI 0.51 - 1.05), specificity of 0.99 (95% CI 0.97 - 1.01), positive predictive value (PPV) of 0.78 (95% CI 0.51 - 1.05) and negative predictive value (NPV) of 0.99 (95% CI 0.97 - 1.01). These findings are concordant with other published studies. The auditconfirmsthatminimal preparation CT colonography is a reasonable alternative to OC and CTC in detecting colorectal cancer in symptomatic elderly and frail patients, without the procedural risks inherent inmore invasive investigations. For most patients MPCTC ruled out significant colorectal carcinoma with a high negative predictive value. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. Added Value of Contrast-Enhanced Spectral Mammography in Postscreening Assessment.

    PubMed

    Tardivel, Anne-Marie; Balleyguier, Corinne; Dunant, Ariane; Delaloge, Suzette; Mazouni, Chafika; Mathieu, Marie-Christine; Dromain, Clarisse

    2016-09-01

    To assess the value on diagnostic and treatment management of contrast-enhanced spectral mammography (CESM), as adjunct to mammography (MG) and ultrasound (US) in postscreening in a breast cancer unit for patients with newly diagnosed breast cancer or with suspicious findings on conventional imaging. Retrospective review of routine use of bilateral CESM performed between September 2012 and September 2013 in 195 women with suspicious or undetermined findings on MG and/or US. CESM images were blindly reviewed by two radiologists for BI-RADS(®) assessment and probability of malignancy. Each lesion was definitely confirmed either with histopathology or follow-up. Two hundred and ninety-nine lesions were detected (221 malignant). CESM sensitivity, specificity, positive-predictive value and negative-predictive value were 94% (CI: 89-96%), 74% (CI: 63-83%), 91% (CI: 86-94%) and 81% (CI: 70-89%), respectively, with 18 false positive and 14 false negative. CESM changed diagnostic and treatment strategy in 41 (21%) patients either after detection of additional malignant lesions in 38 patients (19%)-with a more extensive surgery (n = 21) or neo-adjuvant chemotherapy (n = 1)-or avoiding further biopsy for 20 patients with negative CESM. CESM can be performed easily in a clinical assessment after positive breast cancer screening and may change significantly the diagnostic and treatment strategy through breast cancer staging. © 2016 Wiley Periodicals, Inc.

  5. Diagnostic Accuracy of Global Pharma Health Fund Minilab™ in Assessing Pharmacopoeial Quality of Antimicrobials.

    PubMed

    Pan, Hui; Ba-Thein, William

    2018-01-01

    Global Pharma Health Fund (GPHF) Minilab™, a semi-quantitative thin-layer chromatography (TLC)-based commercially available test kit, is widely used in drug quality surveillance globally, but its diagnostic accuracy is unclear. We investigated the diagnostic accuracy of Minilab system for antimicrobials, using high-performance liquid chromatography (HPLC) as reference standard. Following the Minilab protocols and the Pharmacopoeia of the People's Republic of China protocols, Minilab-TLC and HPLC were used to test five common antimicrobials (506 batches) for relative concentration of active pharmaceutical ingredients. The prevalence of poor-quality antimicrobials determined, respectively, by Minilab TLC and HPLC was amoxicillin (0% versus 14.9%), azithromycin (0% versus 17.4%), cefuroxime axetil (14.3% versus 0%), levofloxacin (0% versus 3.0%), and metronidazole (0% versus 38.0%). The Minilab TLC had false-positive and false-negative detection rates of 2.6% (13/506) and 15.2% (77/506) accordingly, resulting in the following test characteristics: sensitivity 0%, specificity 97.0%, positive predictive value 0, negative predictive value 0.8, positive likelihood ratio 0, negative likelihood ratio 1.0, diagnostic odds ratio 0, and adjusted diagnostic odds ratio 0.2. This study demonstrates unsatisfying diagnostic accuracy of Minilab system in screening poor-quality antimicrobials of common use. Using Minilab as a stand-alone system for monitoring drug quality should be reconsidered.

  6. Intraoperative Evaluation of Breast Tumor Margins with Optical Coherence Tomography

    PubMed Central

    Nguyen, Freddy T.; Zysk, Adam M.; Chaney, Eric J.; Kotynek, Jan G.; Oliphant, Uretz J.; Bellafiore, Frank J.; Rowland, Kendrith M.; Johnson, Patricia A.; Boppart, Stephen A.

    2009-01-01

    As breast cancer screening rates increase, smaller and more numerous lesions are being identified earlier, leading to more breast-conserving surgical procedures. Achieving a clean surgical margin represents a technical challenge with important clinical implications. Optical coherence tomography (OCT) is introduced as an intraoperative high-resolution imaging technique that assesses surgical breast tumor margins by providing real-time microscopic images up to 2 mm beneath the tissue surface. In a study of 37 patients split between training and study groups, OCT images covering 1 cm2 regions were acquired from surgical margins of lumpectomy specimens, registered with ink, and correlated with corresponding histological sections. A 17 patient training set used to establish standard imaging protocols and OCT evaluation criteria demonstrated that areas of higher scattering tissue with a heterogeneous pattern were indicative of tumor cells and tumor tissue, in contrast to lower scattering adipocytes found in normal breast tissue. The remaining 20 patients were enrolled into the feasibility study. Of these lumpectomy specimens, 11 were identified with a positive or close surgical margin and 9 were identified with a negative margin under OCT. Based on histological findings, 9 true positives, 9 true negatives, 2 false positives, and 0 false negatives were found, yielding a sensitivity of 100% and specificity of 82%. These results demonstrate the potential of OCT as a real-time method for intraoperative margin assessment in breast conserving surgeries. PMID:19910294

  7. An assessment of false positive rates for malaria rapid diagnostic tests caused by non-Plasmodium infectious agents and immunological factors.

    PubMed

    Gatton, Michelle L; Ciketic, Sadmir; Barnwell, John W; Cheng, Qin; Chiodini, Peter L; Incardona, Sandra; Bell, David; Cunningham, Jane; González, Iveth J

    2018-01-01

    Malaria rapid diagnostic tests (RDTs) can produce false positive (FP) results in patients with human African trypanosomiasis and rheumatoid factor (RF), but specificity against other infectious agents and immunological factors is largely unknown. Low diagnostic specificity caused by cross-reactivity may lead to over-estimates of the number of malaria cases and over-use of antimalarial drugs, at the cost of not diagnosing and treating the true underlying condition. Data from the WHO Malaria RDT Product Testing Programme was analysed to assess FP rates of 221 RDTs against four infectious agents (Chagas, dengue, Leishmaniasis and Schistosomiasis) and four immunological factors (anti-nuclear antibody, human anti-mouse antibody (HAMA), RF and rapid plasma regain). Only RDTs with a FP rate against clean negative samples less than 10% were included. Paired t-tests were used to compare product-specific FP rates on clean negative samples and samples containing non-Plasmodium infectious agents and immunological factors. Forty (18%) RDTs showed no FP results against any tested infectious agent or immunological factor. In the remaining RDTs significant and clinically relevant increases in FP rates were observed for samples containing HAMA and RF (P<0.001). There were significant correlations between product-matched FP rates for RF and HAMA on all RDT test bands (P<0.001), and FP rates for each infectious agent and immunological factor were also correlated between test bands of combination RDTs (P≤0.002). False positive results against non-Plasmodium infectious agents and immunological factors does not appear to be a universal property of malaria RDTs. However, since many malaria RDTs have elevated FP rates against HAMA and RF positive samples practitioners may need to consider the possibility of false positive results for malaria in patients with conditions that stimulate HAMA or RF.

  8. False memory in aging: effects of emotional valence on word recognition accuracy.

    PubMed

    Piguet, Olivier; Connally, Emily; Krendl, Anne C; Huot, Jessica R; Corkin, Suzanne

    2008-06-01

    Memory is susceptible to distortions. Valence and increasing age are variables known to affect memory accuracy and may increase false alarm production. Interaction between these variables and their impact on false memory was investigated in 36 young (18-28 years) and 36 older (61-83 years) healthy adults. At study, participants viewed lists of neutral words orthographically related to negative, neutral, or positive critical lures (not presented). Memory for these words was subsequently tested with a remember-know procedure. At test, items included the words seen at study and their associated critical lures, as well as sets of orthographically related neutral words not seen at study and their associated unstudied lures. Positive valence was shown to have two opposite effects on older adults' discrimination of the lures: It improved correct rejection of unstudied lures but increased false memory for critical lures (i.e., lures associated with words studied previously). Thus, increased salience triggered by positive valence may disrupt memory accuracy in older adults when discriminating among similar events. These findings likely reflect a source memory deficit due to decreased efficiency in cognitive control processes with aging.

  9. Efficient detection of human circulating tumor cells without significant production of false-positive cells by a novel conditionally replicating adenovirus

    PubMed Central

    Sakurai, Fuminori; Narii, Nobuhiro; Tomita, Kyoko; Togo, Shinsaku; Takahashi, Kazuhisa; Machitani, Mitsuhiro; Tachibana, Masashi; Ouchi, Masaaki; Katagiri, Nobuyoshi; Urata, Yasuo; Fujiwara, Toshiyoshi; Mizuguchi, Hiroyuki

    2016-01-01

    Circulating tumor cells (CTCs) are promising biomarkers in several cancers, and thus methods and apparatuses for their detection and quantification in the blood have been actively pursued. A novel CTC detection system using a green fluorescence protein (GFP)–expressing conditionally replicating adenovirus (Ad) (rAd-GFP) was recently developed; however, there is concern about the production of false-positive cells (GFP-positive normal blood cells) when using rAd-GFP, particularly at high titers. In addition, CTCs lacking or expressing low levels of coxsackievirus–adenovirus receptor (CAR) cannot be detected by rAd-GFP, because rAd-GFP is constructed based on Ad serotype 5, which recognizes CAR. In order to suppress the production of false-positive cells, sequences perfectly complementary to blood cell–specific microRNA, miR-142-3p, were incorporated into the 3′-untranslated region of the E1B and GFP genes. In addition, the fiber protein was replaced with that of Ad serotype 35, which recognizes human CD46, creating rAdF35-142T-GFP. rAdF35-142T-GFP efficiently labeled not only CAR-positive tumor cells but also CAR-negative tumor cells with GFP. The numbers of false-positive cells were dramatically lower for rAdF35-142T-GFP than for rAd-GFP. CTCs in the blood of cancer patients were detected by rAdF35-142T-GFP with a large reduction in false-positive cells. PMID:26966699

  10. Detection of occult, undisplaced hip fractures with a dual-energy CT algorithm targeted to detection of bone marrow edema.

    PubMed

    Reddy, T; McLaughlin, P D; Mallinson, P I; Reagan, A C; Munk, P L; Nicolaou, S; Ouellette, H A

    2015-02-01

    The purpose of this study is to describe our initial clinical experience with dual-energy computed tomography (DECT) virtual non-calcium (VNC) images for the detection of bone marrow (BM) edema in patients with suspected hip fracture following trauma. Twenty-five patients presented to the emergency department at a level 1 trauma center between January 1, 2011 and January 1, 2013 with clinical suspicion of hip fracture and normal radiographs were included. All CT scans were performed on a dual-source, dual-energy CT system. VNC images were generated using prototype software and were compared to regular bone reconstructions by two musculoskeletal radiologists in consensus. Radiological and/or clinical diagnosis of fracture at 30-day follow-up was used as the reference standard. Twenty-one patients were found to have DECT-VNC signs of bone marrow edema. Eighteen of these 21 patients were true positive and three were false positive. A concordant fracture was clearly seen on bone reconstruction images in 15 of the 18 true positive cases. In three cases, DECT-VNC was positive for bone marrow edema where bone reconstruction CT images were negative. Four patients demonstrated no DECT-VNC signs of bone marrow edema: two cases were true negative, two cases were false negative. When compared with the gold standard of hip fracture determined at retrospective follow-up, the sensitivity of DECT-VNC images of the hip was 90 %, specificity was 40 %, positive predictive value was 86 %, and negative predictive value was 50 %. Our initial experience would suggest that DECT-VNC is highly sensitive but poorly specific in the diagnosis of hip fractures in patients with normal radiographs. The value of DECT-VNC primarily lies in its ability to help detect fractures which may be subtle or undetectable on bone reconstruction CT images.

  11. Diagnosis accuracy of two vision screeners for visual health surveillance of workers who use video display terminals

    PubMed Central

    Molina-Torres, María-José; Crespo, María-del-Mar Seguí; Francés, Ana Tauste; Lacarra, Blanca Lumbreras; Ronda-Pérez, Elena

    2016-01-01

    Objective: To compare the diagnostic accuracy of two vision screeners by a visual examination performed by an optometrist (gold standard) and to evaluate the concordance between both screeners and between each screener and the gold standard. Methods: This was a cross-sectional study that included computer workers who attended a routine yearly health examination. The study included administrative office workers (n=91) aged 50.2±7.9 years (mean±standard deviation), 69.2% of whom were women and 68.1% of whom used video display terminals (VDT) for >4 h/day. The routine visual examination included monocular and binocular distance visual acuity (VA), distance and near lateral phoria (LP), stereo acuity (SA), and color vision. Tests were repeated with Optec 6500 (by Stereo Optical) and Visiotest (by Essilor) screeners. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and false positive and negative rates were calculated. Kappa coefficient (κ) was used to measure the concordance of the screeners and the gold standard. Results: The sensitivity and specificity for monocular VA were over 80% for both vision screeners; PPV was below 25%. Sensitivity and specificity were lower for SA (55%-70%), PPV was 50%, and NPV was 75% for both screeners. For distance LP, sensitivity and PPV were <10% in both cases. The screeners differed in their values for near LP: Optec 6500 had higher sensitivity (43.5%), PPV (37.0%), and NPV (79.7%); whereas the Visiotest had higher specificity (83.8%). For color vision, Visiotest showed low sensitivity, low PPV, and high specificity. Visiotest obtained false positive rates that were lower or similar to Optec 6500, and both screeners obtained false negative rates below 50%. Both screeners showed poor concordance (κ<0.40). Conclusions: A high value for NPV would qualify both screeners as acceptable alternatives for visual health surveillance when used as a screening tool; patients with positive test results should be referred to a specialist. PMID:27488039

  12. [Sequential monitoring of renal transplant with aspiration cytology].

    PubMed

    Manfro, R C; Gonçalves, L F; de Moura, L A

    1998-01-01

    To evaluate the utility of kidney aspiration cytology in the sequential monitorization of acute rejection in renal transplant patients. Thirty patients were submitted to 376 aspirations. The clinical diagnoses were independently established. The representativity of the samples reached 82.7%. The total corrected increment index and the number of immunoactivated cells were higher during acute rejection as compared to normal allograft function, acute tubular necrosis, and cyclosporine nephrotoxicity. The parameters to the diagnosis of acute rejection were sensitivity: 71.8%, specificity: 87.3%, positive predictive value: 50.9%, negative predictive value: 94.9% and accuracy 84.9%. The false positive results were mainly related to cytomegalovirus infection or to the administration of OKT3. In 10 out of 11 false negative results incipient immunoactivation was present alerting to the possibility of acute rejection. Kidney aspiration cytology is a useful tool for the sequential monitorization of acute rejection in renal transplant patients. The best results are reached when the results of aspiration cytology are analyzed with the clinical data.

  13. Practical application of contrast-enhanced magnetic resonance mammography [CE-MRM] by an algorithm combining morphological and enhancement patterns.

    PubMed

    Potente, Giuseppe; Messineo, Daniela; Maggi, Claudia; Savelli, Sara

    2009-03-01

    The purpose of this article is to report our practical utilization of dynamic contrast-enhanced magnetic resonance mammography [DCE-MRM] in the diagnosis of breast lesions. In many European centers, was preferred a high-temporal acquisition of both breasts simultaneously in a large FOV. We preferred to scan single breasts, with the aim to combine the analysis of the contrast intake and washout with the morphological evaluation of breast lesions. We followed an interpretation model, based upon a diagnostic algorithm, which combined contrast enhancement with morphological evaluation, in order to increase our confidence in diagnosis. DCE-MRM with our diagnostic algorithm has identified 179 malignant and 41 benign lesions; final outcome has identified 178 malignant and 42 benign lesions, 3 false positives and 2 false negatives. Sensitivity of CE-MRM was 98.3%; specificity, 95.1%; positive predictive value, 98.9%; negative predictive value, 92.8% and accuracy, 97.7%.

  14. Clinical value of polymerase chain reaction in the diagnosis of joint tuberculosis by detecting the DNA of Mycobacterium tuberculosis.

    PubMed

    Sun, Yong-sheng; Lou, Si-quan; Wen, Jian-min; Lv, Wei-xin; Jiao, Chang-geng; Yang, Su-min; Xu, Hai-bin

    2011-02-01

    To assess the clinical value of polymerase chain reaction (PCR) in the diagnosis and differential diagnosis of joint tuberculosis (TB). PCR was used blindly to detect the DNA of Mycobacterium tuberculosis (M.TB) in five specimens of M.TB, 5 of BCG, and 10 of other bacteria. Then, M. TB in 98 samples from patients with joint TB and 100 samples from patients with non-tubercular joint disorders were detected by PCR, acid-fast staining and culture,. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of PCR were calculated. The χ2 test was used for statistical analysis of the frequency of various factors. At the same time, some problems with PCR were also systematically analyzed. (1) In the "standard samples", both M. TB and BCG showed positive while other bacteria were negative. (2) In 98 cases from patients with joint TB, 81 were positive by PCR, 6 by acid-fast staining, and 17 by culture. In 100 cases from patients with non-tuberculous joint disorders, 9 were positive by PCR, and none by either acid-fast staining or culture. Sensitivity, specificity, accuracy, positive and negative predictive value of PCR were 82.65% (81/98), 91.00% (91/100), 86.87% (172/198), 90.00% (81/90) and 84.26% (91/108), respectively. (3) The positive rates for PCR, acid-fast staining and culture in detection of M. TB were 82.65% (81/98), 6.12% (6/98), and 17.34% (17/98), respectively. There were statistically significant differences between the three methods (P < 0.001). (4) The process of PCR is automatic, and can be completed within 3 to 6 hours, whereas 4 to 8 weeks are required for the conventional culture of M. TB. PCR is a sensitive, specific, rapid, simple and minimally invasive method for detection of M. TB in samples from joint TB, and can play an important role in early and rapid diagnosis and differential diagnosis of joint TB. But it also has some limitations, such as false positivity and false negativity. © 2011 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.

  15. Deducing the Milky Way's Massive Cluster Population

    NASA Astrophysics Data System (ADS)

    Hanson, M. M.; Popescu, B.; Larsen, S. S.; Ivanov, V. D.

    2010-11-01

    Recent near-infrared surveys of the galactic plane have been used to identify new massive cluster candidates. Follow up study indicates about half are not true, gravitationally-bound clusters. These false positives are created by high density fields of unassociated stars, often due to a sight-line of reduced extinction. What is not so easy to estimate is the number of false negatives, clusters which exist but are not currently being detected by our surveys. In order to derive critical characteristics of the Milky Way's massive cluster population, such as cluster mass function and cluster lifetimes, one must be able to estimate the characteristics of these false negatives. Our group has taken on the daunting task of attempting such an estimate by first creating the stellar cluster imaging simulation program, MASSCLEAN. I will present our preliminary models and methods for deriving the biases of current searches.

  16. Performance of two hearing screening protocols in NICU in Shanghai.

    PubMed

    Xu, Zheng-Min; Cheng, Wen-Xia; Yang, Xiao-Lin

    2011-10-01

    To study the sensitivity and specificity of targeted neonatal hearing screening for the single-session distortion product otoacoustic emissions (DPOAE) technique and the combined DPOAE/automated auditory brain-stem response (AABR) technique. 3000 high-risk newborns were studied at Children's Hospital of Fudan University. They were required to take two different screening procedures separately. The first procedure consisted of DPOAE alone and the second consisted of DPOAE combined with the AABR. Based upon the etiology in high-risk babies, they were divided into four groups. In group I there were 670 very-low-birth-weight (VLBW) newborns (1340 ears), and in group II there were 890 preterm babies (1780 ears). 850 babies (1700 ears) suffered from hyperbilirubinemia in group III, whereas 790 babies (1580 ears) with asphyxia were in group IV. The babies in groups II, III, and IV came from the neonatal intensive-care unit (NICU) of our hospital. The study protocols consisted of the DPOAE alone and DPOAE combined with AABR hearing screening at an age of less than 1 month, and a diagnostic stage at the age of 2 months. With single-session DPOAE screening, the referral rate (8% of the NICU babies), the false-positive rate (4.96%) and the false-negative rate (0.8%) were higher. The different etiologies in NICU babies had significantly different referral rates (F-test, p<0.01). A 4.46% referral rate of hyperbilirubinemi babies was much lower. The combined DPOAE/AABR screening technique revealed a referral rate of 5.03%, a false-positive rate of 2% and a false-negative rate of 0.06%. The false-positive rate was well below the suggested 3% of the American Academy of Pediatric. Comparisons of the referral rate, false-positive rate and false-negative rate of two hearing screening protocols (DPOAE alone and combined DPOAE/AABR) revealed significant differences (t-test, p<0.05, p<0.01, p<0.01). 91 infants (3.03% of the NICU babies) who failed the combined DPOAE/AABR screening were confirmed on hearing impairment. Of 22 babies who passed DPOAE screening but failed the AABR screening had a severe to profound hearing loss based on classic ABR. These patients (24% of the NICU babies with hearing losses) with hyperbilirubinemia and asphyxia problems at newborn stage were diagnosed as auditory neuropathy based on evaluations of DPOAE screening passed, abnormal ABR and absent middle-ear muscle reflexes (MMR). Our study demonstrates the use of a combination of DPOAE and AABR testing ensures high sensitivity and acceptable specificity, and predict the AN profile in NICU babies. Our efforts identified 22 NICU babies with auditory neuropathy who hopefully will benefit from early remediation of their hearing deficit. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. Sentinel Lymph Node Biopsy After Neoadjuvant Chemotherapy in Patients With an Initial Diagnosis of Cytology-Proven Lymph Node-Positive Breast Cancer.

    PubMed

    Enokido, Katsutoshi; Watanabe, Chie; Nakamura, Seigo; Ogiya, Akiko; Osako, Tomo; Akiyama, Futoshi; Yoshimura, Akiyo; Iwata, Hiroji; Ohno, Shinji; Kojima, Yasuyuki; Tsugawa, Koichiro; Motomura, Kazuyoshi; Hayashi, Naoki; Yamauchi, Hideko; Sato, Nobuaki

    2016-08-01

    Sentinel lymph node biopsy (SNB) is the standard treatment of node-negative breast cancer; however, whether SNB should be performed for patients with node-positive disease before neoadjuvant chemotherapy (NAC) is controversial. We evaluated the accuracy of SNB after NAC in patients with breast cancer with nodal metastasis before chemotherapy to determine the false-negative rate (FNR) and detection rate for SNB. In the present multicenter prospective study performed from September 2011 to April 2013, 143 patients with breast cancer and positive axillary nodes, proved by fine needle aspiration cytology at the initial diagnosis (stage T1-T3N1M0), were enrolled. All patients underwent breast surgery with SNB and complete axillary lymph node dissection. After NAC, the pathologic complete nodal response rate was 52.4%. The sentinel lymph node could be identified in 130 cases (90.9%); the FNR was 16.0% (13 of 81). The FNR of each clinical subtype was 42.1% (8 of 19) for the estrogen receptor-positive and human epithelial growth factor 2 (HER2)-negative (luminal type), 16.7% (2 of 12) for ER-positive and HER2-positive (luminal-HER2 type), 3.2% (1 of 31) for HER2-positive (HER2-enriched type), and 10.5% (2 of 19) for ER-negative and HER2-negative (triple-negative breast cancer; P = .003). The FNR was significantly greater in the luminal than in the nonluminal type (odds ratio, 9.91; 95% confidence interval, 6.77-14.52). SNB after NAC in patients with initially node-positive breast cancer was technically feasible but should not be recommended for the luminal subtype. However, the tumor subtype can guide patient selection, and axillary lymph node dissection could be omitted for the luminal-HER2, HER2-enriched, and triple-negative breast cancer subtypes. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  18. Detection of CIN by naked eye visualization after application of acetic acid.

    PubMed

    Londhe, M; George, S S; Seshadri, L

    1997-06-01

    A prospective study was undertaken to determine the sensitivity and specificity of acetic application to the cervix followed by naked eye visualization as a screening test for detection of cervical intraepithelial neoplasia. Three hundred and seventy two sexually active woman in the reproductive age group were studied. All the women underwent Papanicolaou test, acetic acid test and colposcopy. One hundred and seventy five woman were acetic acid test negative, 197 women were acetic acid test positive. The sensitivity of acetic acid test was 72.4%, specificity 54% and false negative rate 15.2%, as compared to papanicolaou test which had a sensitivity of 13.2%, specificity of 96.3% and false negative rate of 24.4%. The advantage of the acetic acid test lies in its easy technique, low cost and high sensitivity which are important factors for determining the efficacy of any screening programme in developing countries.

  19. Do the benefits outweigh the side effects of colorectal cancer surveillance? A systematic review.

    PubMed

    Augestad, Knut Magne; Rose, Johnie; Crawshaw, Benjamin; Cooper, Gregory; Delaney, Conor

    2014-05-15

    Most patients treated with curative intent for colorectal cancer (CRC) are included in a follow-up program involving periodic evaluations. The survival benefits of a follow-up program are well delineated, and previous meta-analyses have suggested an overall survival improvement of 5%-10% by intensive follow-up. However, in a recent randomized trial, there was no survival benefit when a minimal vs an intensive follow-up program was compared. Less is known about the potential side effects of follow-up. Well-known side effects of preventive programs are those of somatic complications caused by testing, negative psychological consequences of follow-up itself, and the downstream impact of false positive or false negative tests. Accordingly, the potential survival benefits of CRC follow-up must be weighed against these potential negatives. The present review compares the benefits and side effects of CRC follow-up, and we propose future areas for research.

  20. Value of contrast-enhanced ultrasound in differential diagnosis of solid lesions of pancreas (SLP): A systematic review and a meta-analysis.

    PubMed

    Ran, Li; Zhao, Wenli; Zhao, Ye; Bu, Huaien

    2017-07-01

    Contrast-enhanced ultrasound (CEUS) is considered a novel method for diagnosing pancreatic cancer, but currently, there is no conclusive evidence of its accuracy. Using CEUS in discriminating between pancreatic carcinoma and other pancreatic lesions, we aimed to evaluate the diagnostic accuracy of CEUS in predicting pancreatic tumours. Relevant studies were selected from the PubMed, Cochrane Library, Elsevier, CNKI, VIP, and WANFANG databases dating from January 2006 to May 2017. The following terms were used as keywords: "pancreatic cancer" OR "pancreatic carcinoma," "contrast-enhanced ultrasonography" OR "contrast-enhanced ultrasound" OR "CEUS," and "diagnosis." The selection criteria are as follows: pancreatic carcinomas diagnosed by CEUS while the main reference standard was surgical pathology or biopsy (if it involved a clinical diagnosis, particular criteria emphasized); SonoVue or Levovist was the contrast agent; true positive, false positive, false negative, and true negative rates were obtained or calculated to construct the 2 × 2 contingency table; English or Chinese articles; at least 20 patients were enrolled in each group. The Quality Assessment for Studies of Diagnostic Accuracy was employed to evaluate the quality of articles. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, summary receiver-operating characteristic curves, and the area under curve were evaluated to estimate the overall diagnostic efficiency. Pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio with 95% confidence intervals (CIs) were calculated with fixed-effect models. Eight of 184 records were eligible for a meta-analysis after independent scrutinization by 2 reviewers. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratios were 0.86 (95% CI 0.81-0.90), 0.75 (95% CI 0.68-0.82), 3.56 (95% CI 2.64-4.78), 0.19 (95% CI 0.13-0.27), and 22.260 (95% CI 8.980-55.177), respectively. The area under the SROC curve was 0.9088. CEUS has a satisfying pooled sensitivity and specificity for discriminating pancreatic cancer from other pancreatic lesions.

  1. Minimising Immunohistochemical False Negative ER Classification Using a Complementary 23 Gene Expression Signature of ER Status

    PubMed Central

    Li, Qiyuan; Eklund, Aron C.; Juul, Nicolai; Haibe-Kains, Benjamin; Workman, Christopher T.; Richardson, Andrea L.; Szallasi, Zoltan; Swanton, Charles

    2010-01-01

    Background Expression of the oestrogen receptor (ER) in breast cancer predicts benefit from endocrine therapy. Minimising the frequency of false negative ER status classification is essential to identify all patients with ER positive breast cancers who should be offered endocrine therapies in order to improve clinical outcome. In routine oncological practice ER status is determined by semi-quantitative methods such as immunohistochemistry (IHC) or other immunoassays in which the ER expression level is compared to an empirical threshold[1], [2]. The clinical relevance of gene expression-based ER subtypes as compared to IHC-based determination has not been systematically evaluated. Here we attempt to reduce the frequency of false negative ER status classification using two gene expression approaches and compare these methods to IHC based ER status in terms of predictive and prognostic concordance with clinical outcome. Methodology/Principal Findings Firstly, ER status was discriminated by fitting the bimodal expression of ESR1 to a mixed Gaussian model. The discriminative power of ESR1 suggested bimodal expression as an efficient way to stratify breast cancer; therefore we identified a set of genes whose expression was both strongly bimodal, mimicking ESR expression status, and highly expressed in breast epithelial cell lines, to derive a 23-gene ER expression signature-based classifier. We assessed our classifiers in seven published breast cancer cohorts by comparing the gene expression-based ER status to IHC-based ER status as a predictor of clinical outcome in both untreated and tamoxifen treated cohorts. In untreated breast cancer cohorts, the 23 gene signature-based ER status provided significantly improved prognostic power compared to IHC-based ER status (P = 0.006). In tamoxifen-treated cohorts, the 23 gene ER expression signature predicted clinical outcome (HR = 2.20, P = 0.00035). These complementary ER signature-based strategies estimated that between 15.1% and 21.8% patients of IHC-based negative ER status would be classified with ER positive breast cancer. Conclusion/Significance Expression-based ER status classification may complement IHC to minimise false negative ER status classification and optimise patient stratification for endocrine therapies. PMID:21152022

  2. Evaluation of GeneXpert MTB/RIF for detection of Mycobacterium tuberculosis complex and rpo B gene in respiratory and non-respiratory clinical specimens at a tertiary care teaching hospital in Saudi Arabia.

    PubMed

    Somily, Ali M; Barry, Mazin A; Habib, Hanan A; Alotaibi, Fawzia E; Al-Zamil, Fahad A; Khan, Mohammed A; Sarwar, Mohammed S; Bakhash, Nawab D; Alrabiaah, Abdulkarim A; Shakoor, Zahid A; Senok, Abiola C

    2016-12-01

    To assess the performance of Xpert MTB/RIF, an automated molecular test for Mycobacterium tuberculosis (MTB) and resistance to rifampin (RIF), against smear microscopy and culture method for diagnosis of MTB infection. Methods: This is a retrospective analysis of 103 respiratory and 137 non-respiratory patient specimens suspected of tuberculosis at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia performed between April 2014 and March 2015. Each sample underwent smear microscopy, mycobacterial culture, and GeneXpert MTB/RIF test. Results: Fifteen out of 103 respiratory samples were smear and culture positive, whereas 9 out of 137 non-respiratory samples were smear positive. Out of 9 smear positive specimens, 8 were also culture positive. All 15 culture positive respiratory samples were detected by Xpert MTB/RIF (sensitivity  and positive predictive value [PPV]=100%). Similarly, all 8 culture positive non-respiratory specimens were identified by Xpert MTB/RIF (sensitivity 100%; PPV 88.8%). The Xpert MTB/RIF detected only one false positive result in 88 smear negative respiratory specimens (specificity 98.9%; negative predictive value [NPV]= 100%). All 125 smear negative non-respiratory specimens tested negative by culture and Xpert MTB/RIF (sensitivity, specificity, PPV, NPV= 100%). Conclusion: The performance of Xpert MTB/RIF was comparable to the gold standard culture method for identification of MTB in both respiratory and non-respiratory clinical specimens.

  3. Evaluation of GeneXpert MTB/RIF for detection of Mycobacterium tuberculosis complex and rpo B gene in respiratory and non-respiratory clinical specimens at a tertiary care teaching hospital in Saudi Arabia

    PubMed Central

    Somily, Ali M.; Barry, Mazin A.; Habib, Hanan A.; Alotaibi, Fawzia E.; Al-Zamil, Fahad A.; Khan, Mohammed A.; Sarwar, Mohammed S.; Bakhash, Nawab D.; Alrabiaah, Abdulkarim A.; Shakoor, Zahid A.; Senok, Abiola C.

    2016-01-01

    Objectives To assess the performance of Xpert MTB/RIF, an automated molecular test for Mycobacterium tuberculosis (MTB) and resistance to rifampin (RIF), against smear microscopy and culture method for diagnosis of MTB infection. Methods This is a retrospective analysis of 103 respiratory and 137 non-respiratory patient specimens suspected of tuberculosis at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia performed between April 2014 and March 2015. Each sample underwent smear microscopy, mycobacterial culture, and GeneXpert MTB/RIF test. Results Fifteen out of 103 respiratory samples were smear and culture positive, whereas 9 out of 137 non-respiratory samples were smear positive. Out of 9 smear positive specimens, 8 were also culture positive. All 15 culture positive respiratory samples were detected by Xpert MTB/RIF (sensitivity and positive predictive value [PPV]=100%). Similarly, all 8 culture positive non-respiratory specimens were identified by Xpert MTB/RIF (sensitivity 100%; PPV 88.8%). The Xpert MTB/RIF detected only one false positive result in 88 smear negative respiratory specimens (specificity 98.9%; negative predictive value [NPV]= 100%). All 125 smear negative non-respiratory specimens tested negative by culture and Xpert MTB/RIF (sensitivity, specificity, PPV, NPV= 100%). Conclusion The performance of Xpert MTB/RIF was comparable to the gold standard culture method for identification of MTB in both respiratory and non-respiratory clinical specimens. PMID:27874159

  4. Pre-Participation Musculoskeletal and Cardiac Screening of Male Athletes in the United Arab Emirates

    PubMed Central

    Alattar, A; Ghani, S; Mahdy, N; Hussain, H; Maffulli, N

    2014-01-01

    This study presents the results of pre-participation musculoskeletal and cardiac screening using the Lausanne recommendations, which include a personal and family history, physical examination and electrocardiography. Cross sectional study using the Lausanne screenings and the European Society of Cardiology (ESC) recommendations carried out at Al-Ahli club in Dubai, United Arab Emirates. 230 male athletes participating in organised sports were included. Exclusion criteria were those under 14 or over 35 years old, females and athletes with established cardiovascular disease. Primary outcome are the results of Lausanne screening with outline of the negative, positive and false positive results and number needed to screen. Secondary outcomes include the results of musculoskeletal and neurological screening. A total of 174 (76%) athletes had a negative screening result. Fifty-four athletes (23%) underwent additional testing. Forty-seven athletes (20.4%) had false positive screening results. Seven athletes (3%) had a positive screening result and four athletes (2%) were restricted from sport. The number of athletes needed to screen to detect one lethal cardiovascular condition was 33 athletes. The Lausanne recommendations are well suited for the United Arab Emirates. The number needed to screen to detect one athlete with serious cardiovascular disease is acceptable at 33. PMID:24809035

  5. Validity of HydraTrend reagent strips for the assessment of hydration status.

    PubMed

    Abbey, Bryce M; Heelan, Kate A; Brown, Gregory A; Bartee, Rodrick T

    2014-09-01

    Hydration is used by athletic governing organizations for weight class eligibility. The measurement of urine specific gravity (USG) as a measure of hydration by reagent strips is a controversial issue. The purpose of this study was to determine the validity of HydraTrend reagent strips that facilitate the correction of USG for alkaline urine samples against refractometry for the assessment of USG. Fifty-one participants (33 males, age = 22.3 ± 1.3 years; 18 females, age = 22.4 ± 1.2 years) provided 84 urine samples. The samples were tested for USG using refractometry and reagent strips and for pH using reagent strips and a digital pH meter. Strong correlation coefficients were found between refractometry and reagent strips for USG (rs(82) = 0.812, p < 0.01) and between reagent strips and pH meter for pH (rs(82) = 0.939, p < 0.01). It was observed that false negative results for National Collegiate Athletic Association (NCAA) requirements (fail refractometry with USG >1.020, pass reagent strips with USG ≤1.020) occurred 39% (33/84) of the time and false negative results for National Federation of State High School Association (NFHS) requirements (fail refractometry with USG >1.025, pass reagent strips with USG ≤1.025) occurred 14% (12/84) of the time. There were no false positives (pass refractometry and fail reagent strips) for NCAA or NFHS requirements. These data show that refractometry and reagent strips have strong positive correlations. However, the risk of a false negative result leading to incorrect certification of euhydration status outweighs the benefits of the HydraTrend reagent strips for the measurement of USG.

  6. Substantial underreporting of anastomotic leakage after anterior resection for rectal cancer in the Swedish Colorectal Cancer Registry.

    PubMed

    Rutegård, Martin; Kverneng Hultberg, Daniel; Angenete, Eva; Lydrup, Marie-Louise

    2017-12-01

    The causes and effects of anastomotic leakage after anterior resection are difficult to study in small samples and have thus been evaluated using large population-based national registries. To assess the accuracy of such research, registries should be validated continuously. Patients who underwent anterior resection for rectal cancer during 2007-2013 in 15 different hospitals in three healthcare regions in Sweden were included in the study. Registry data and information from patient records were retrieved. Registered anastomotic leakage within 30 postoperative days was evaluated, using all available registry data and using only the main variable anastomotic insufficiency. With the consensus definition of anastomotic leakage developed by the International Study Group on Rectal Cancer as reference, validity measures were calculated. Some 1507 patients were included in the study. The negative and positive predictive values for registered anastomotic leakage were 96 and 88%, respectively, while the κ-value amounted to 0.76. The false-negative rate was 29%, whereas the false-positive rate reached 1.3% (the vast majority consisting of actual leaks, but occurring after postoperative day 30). Using the main variable anastomotic insufficiency only, the false-negative rate rose to 41%. There is considerable underreporting of anastomotic leakage after anterior resection for rectal cancer in the Swedish Colorectal Cancer Registry. It is probable that this causes an underestimation of the true effects of leakage on patient outcomes, and further quality control is needed.

  7. Sociopathic Knowledge Bases: Correct Knowledge Can Be Harmful Even Given Unlimited Computation

    DTIC Science & Technology

    1989-08-01

    pobitive, as false positives generated by a medical program can often be caught by a physician upon further testing . False negatives, however, may be...improvement over the knowledge base tested is obtained. Although our work is pretty much theoretical research oriented one example of ex- periments is...knowledge base, improves the performance by about 10%. of tests . First, we divide the cases into a training set and a validation set with 70% vs. 30% each

  8. Advances in nuclear medicine.

    PubMed

    Selberg, Kurt; Ross, Michael

    2012-12-01

    Nuclear scintigraphy is a mainstay of diagnostic imaging and has preserved its relevance in the imaging of acute and chronic trauma. It is particularly useful in the evaluation of athletic injuries. Pitfalls of interpretation, false negatives and false positives exist as with many imaging modalities. Synthesis of physical exam findings, lameness evaluation and, when possible, diagnostic analgesia in combination with nuclear scintigraphy imaging findings, will allow for the most information to be applied to the patient's clinical problem. Published by Elsevier Inc.

  9. A Study of False-Positive and False-Negative Error Rates in Cartridge Case Comparisons

    DTIC Science & Technology

    2014-04-07

    materials for the study, in particular Vicki Sieve. 3 Abstract: This report provides the details for a study designed to...participate in ASCLD were provided with 15 sets of 3 known + 1 unknown cartridge cases fired from a collection of 25 new Ruger SR9 handguns . The...answer sheet allowing for the AFTE range of conclusions, and return shipping materials . They were also asked to assess how many of the 3 knowns were

  10. Accounting for heterogeneous treatment effects in the FDA approval process.

    PubMed

    Malani, Anup; Bembom, Oliver; van der Laan, Mark

    2012-01-01

    The FDA employs an average-patient standard when reviewing drugs: it approves a drug only if is safe and effective for the average patient in a clinical trial. It is common, however, for patients to respond differently to a drug. Therefore, the average-patient standard can reject a drug that benefits certain patient subgroups (false negatives) and even approve a drug that harms other patient subgroups (false positives). These errors increase the cost of drug development - and thus health care - by wasting research on unproductive or unapproved drugs. The reason why the FDA sticks with an average patient standard is concern about opportunism by drug companies. With enough data dredging, a drug company can always find some subgroup of patients that appears to benefit from its drug, even if the subgroup truly does not. In this paper we offer alternatives to the average patient standard that reduce the risk of false negatives without increasing false positives from drug company opportunism. These proposals combine changes to institutional design - evaluation of trial data by an independent auditor - with statistical tools to reinforce the new institutional design - specifically, to ensure the auditor is truly independent of drug companies. We illustrate our proposals by applying them to the results of a recent clinical trial of a cancer drug (motexafin gadolinium). Our analysis suggests that the FDA may have made a mistake in rejecting that drug.

  11. Comparison of 3 Methods to Assess Urine Specific Gravity in Collegiate Wrestlers.

    PubMed

    Stuempfle, Kristin J.; Drury, Daniel G.

    2003-12-01

    OBJECTIVE: To investigate the reliability and validity of refractometry, hydrometry, and reagent strips in assessing urine specific gravity in collegiate wrestlers. DESIGN AND SETTING: We assessed the reliability of refractometry, hydrometry, and reagent strips between 2 trials and among 4 testers. The validity of hydrometry and reagent strips was assessed by comparison with refractometry, the criterion measure for urine specific gravity. SUBJECTS: Twenty-one National Collegiate Athletic Association Division III collegiate wrestlers provided fresh urine samples. MEASUREMENTS: Four testers measured the specific gravity of each urine sample 6 times: twice by refractometry, twice by hydrometry, and twice by reagent strips. RESULTS: Refractometer measurements were consistent between trials (R =.998) and among testers; hydrometer measurements were consistent between trials (R =.987) but not among testers; and reagent-strip measurements were not consistent between trials or among testers. Hydrometer (1.018 +/- 0.006) and reagent-strip (1.017 +/- 0.007) measurements were significantly higher than refractometer (1.015 +/- 0.006) measurements. Intraclass correlation coefficients were moderate between refractometry and hydrometry (R =.869) and low between refractometry and reagent strips (R =.573). The hydrometer produced 28% false positives and 2% false negatives, and reagent strips produced 15% false positives and 9% false negatives. CONCLUSIONS: Only the refractometer should be used to determine urine specific gravity in collegiate wrestlers during the weight-certification process.

  12. The introduction of the absolute risk for the detection of fetal aneuploidies in the first-trimester screening.

    PubMed

    Padula, Francesco; Laganà, Antonio Simone; Vitale, Salvatore Giovanni; D'Emidio, Laura; Coco, Claudio; Giannarelli, Diana; Cariola, Maria; Favilli, Alessandro; Giorlandino, Claudio

    2017-05-01

    Maternal age is a crucial factor in fetal aneuploidy screening, resulting in an increased rate of false-positive cases in older women and false-negative cases in younger women. The absolute risk (AR) is the simplest way to eliminate the background maternal age risk, as it represents the amount of improvement of the combined risk from the maternal background risk. The aim of this work is to assess the performance of the AR in the combined first-trimester screening for aneuploidies. A retrospective validation of the AR in the combined first-trimester screening for fetal aneuploidies, in an unselected population at Altamedica Fetal-Maternal Medical Center in Rome, between March 2007 and December 2008. Of 3845 women included in the study, we had a complete follow-up on 2984. We evaluated that an AR < 3 would individuate 22 of 23 cases of aneuploidy with a detection rate of 95.7% (95%CI 87.3-100), a false-positive rate of 8.7% (95%CI 7.7-9.7) and a false-negative rate of 4.3% (95%CI 0-12.7). In our study, the AR ameliorates the detection rate for aneuploidy. Further research and a prospective study on a larger population would help us to improve the AR in detecting most cases of aneuploidy.

  13. Comparison of 3 Methods to Assess Urine Specific Gravity in Collegiate Wrestlers

    PubMed Central

    Drury, Daniel G.

    2003-01-01

    Objective: To investigate the reliability and validity of refractometry, hydrometry, and reagent strips in assessing urine specific gravity in collegiate wrestlers. Design and Setting: We assessed the reliability of refractometry, hydrometry, and reagent strips between 2 trials and among 4 testers. The validity of hydrometry and reagent strips was assessed by comparison with refractometry, the criterion measure for urine specific gravity. Subjects: Twenty-one National Collegiate Athletic Association Division III collegiate wrestlers provided fresh urine samples. Measurements: Four testers measured the specific gravity of each urine sample 6 times: twice by refractometry, twice by hydrometry, and twice by reagent strips. Results: Refractometer measurements were consistent between trials (R = .998) and among testers; hydrometer measurements were consistent between trials (R = .987) but not among testers; and reagent-strip measurements were not consistent between trials or among testers. Hydrometer (1.018 ± 0.006) and reagent-strip (1.017 ± 0.007) measurements were significantly higher than refractometer (1.015 ± 0.006) measurements. Intraclass correlation coefficients were moderate between refractometry and hydrometry (R = .869) and low between refractometry and reagent strips (R = .573). The hydrometer produced 28% false positives and 2% false negatives, and reagent strips produced 15% false positives and 9% false negatives. Conclusions: Only the refractometer should be used to determine urine specific gravity in collegiate wrestlers during the weight-certification process. PMID:14737213

  14. Evaluation of the light scattering and the turbidity microtiter plate-based methods for the detection of the excipient-mediated drug precipitation inhibition.

    PubMed

    Petruševska, Marija; Urleb, Uroš; Peternel, Luka

    2013-11-01

    The excipient-mediated precipitation inhibition is classically determined by the quantification of the dissolved compound in the solution. In this study, two alternative approaches were evaluated, one is the light scattering (nephelometer) and other is the turbidity (plate reader) microtiter plate-based methods which are based on the quantification of the compound precipitate. Following the optimization of the nephelometer settings (beam focus, laser gain) and the experimental conditions, the screening of 23 excipients on the precipitation inhibition of poorly soluble fenofibrate and dipyridamole was performed. The light scattering method resulted in excellent correlation (r>0.91) between the calculated precipitation inhibitor parameters (PIPs) and the precipitation inhibition index (PI(classical)) obtained by the classical approach for fenofibrate and dipyridamole. Among the evaluated PIPs AUC100 (nephelometer) resulted in only four false positives and lack of false negatives. In the case of the turbidity-based method a good correlation of the PI(classical) was obtained for the PIP maximal optical density (OD(max), r=0.91), however, only for fenofibrate. In the case of the OD(max) (plate reader) five false positives and two false negatives were identified. In conclusion, the light scattering-based method outperformed the turbidity-based one and could be reliably used for identification of novel precipitation inhibitors. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Inflammatory disorders mimicking periprosthetic joint infections may result in false positive α-defensin.

    PubMed

    Plate, Andreas; Stadler, Laura; Sutter, Reto; Anagnostopoulos, Alexia; Frustaci, Dario; Zbinden, Reinhard; Fucentese, Sandro F; Zinkernagel, Annelies S; Zingg, Patrick O; Achermann, Yvonne

    2018-02-26

    The antimicrobial peptide α-defensin has recently been introduced as potential "single" biomarker with a high sensitivity and specificity for the preoperative diagnosis of periprosthetic joint infections (PJIs). However, most studies assessed the benefits of the test with exclusion of patients with rheumatic diseases. We aimed to evaluate the α-defensin test in a cohort study without exclusion of cases with inflammatory diseases. Between June 2016 and June 2017, we prospectively included cases with a suspected PJI and an available lateral flow test α-defensin (Synovasure®) in synovial fluid. We compared the test result to the diagnostic criteria for PJIs published by an International Consensus Group in 2013. We included 109 cases (49 hips, 60 knees) in which preoperative α-defensin tests had been performed. Thereof, 20 PJIs (16 hips, 4 knees) were diagnosed. Preoperative α-defensin tests were positive in 25 cases (22.9%) with a test sensitivity and specificity of 90% and 92.1% (95% confidence interval [CI], 68.3 - 98.8% and 84.5 - 96.8%, respectively), and a high negative predictive value of 97.6% (95% CI, 91.7 - 99.4%). We interpreted seven α-defensin tests as false positive, mainly in cases with inflammatory rheumatic diseases, including crystal deposition diseases. A negative synovial α-defensin test can reliably rule out a PJI. However, the test can be false positive in conjunction with an underlying non-infectious inflammatory disease. We therefore propose to use the α-defensin test only in addition to MSIS criteria and assessment for crystals in synovial aspirates. Copyright © 2018. Published by Elsevier Ltd.

  16. 0-6656 : ASR testing : a new approach to aggregate classification and mix design verification : [project summary].

    DOT National Transportation Integrated Search

    2014-08-01

    In the past 5.5 years, the Texas Department of Transportation (TxDOT) spent approximately $2 million for recasting precast concrete products that had alkali-silica reaction (ASR). Aggregates belonging to false positive and negative categories based o...

  17. Malaria rapid diagnostic test evaluation at private retail pharmacies in Kumasi, Ghana.

    PubMed

    Audu, Rauf; Anto, Berko Panyin; Koffuor, George Asumeng; Abruquah, Akua Afriyie; Buabeng, Kwame Ohene

    2016-01-01

    Malaria rapid diagnostic test (MRDT) provides a good alternative to malaria microscopy diagnosis, particularly in resource-constrained settings. This study therefore evaluated MRDT in private retail pharmacies (PRPs) as a critical step in community case malaria management. In a prospective, cross-over, validation survey at six PRPs in the Ashanti Region of Ghana, 1200 patients presenting with fever in the preceding 48 h were sampled. Fingerstick blood samples were collected for preparation of thick and thin blood films for malaria microscopy. Categorized patients (600 each) went through the processes of MRDT or presumptive diagnosis (PD) of malaria. The malaria disease prevalence of the study area was established. Selectivity (Se), specificity (Sp), positive predictive value (PPV) along with false discovery rate (FDR), and negative predictive value (NPV) along with the false omission rate (FOR), and diagnostic odds ratio (DOR) of MRDT were then calculated. While 43.0% tested positive using the MRDT, 57.0% tested negative. However, 62.0% MRDT-negative patients in addition to all the MRDT positives were given artemether-lumefantrine. Of those diagnosed by PD, 98.2% were prescribed with an antimalarial (microscopy however confirmed only 70.3% as positive). Se and Sp of the MRDT were 90.68 ± 11.18% and 98.68 ± 1.19%, respectively. Malaria prevalence was estimated to be 43.3%. PPV was 98.0%, FDR was 2.0%, NPV was 98.0%, FOR was 2.0%, and DOR was 2366.43. Results highlighted good performance of MRDTs at PRPs which could inform decision toward its implementation.

  18. Female False Positive Exercise Stress ECG Testing - Fact Verses Fiction.

    PubMed

    Fitzgerald, Benjamin T; Scalia, William M; Scalia, Gregory M

    2018-03-07

    Exercise stress testing is a well validated cardiovascular investigation. Accuracy for treadmill stress electrocardiograph (ECG) testing has been documented at 60%. False positive stress ECGs (exercise ECG changes with non-obstructive disease on anatomical testing) are common, especially in women, limiting the effectiveness of the test. This study investigates the incidence and predictors of false positive stress ECG findings, referenced against stress echocardiography (SE) as a standard. Stress echocardiography was performed using the Bruce treadmill protocol. False positive stress ECG tests were defined as greater than 1mm of ST depression on ECG during exertion, without pain, with a normal SE. Potential causes for false positive tests were recorded before the test. Three thousand consecutive negative stress echocardiograms (1036 females, 34.5%) were analysed (age 59+/-14 years. False positive (F+) stress ECGs were documented in 565/3000 tests (18.8%). F+ stress ECGs were equally prevalent in females (194/1036, 18.7%) and males (371/1964, 18.9%, p=0.85 for the difference). Potential causes (hypertension, left ventricular hypertrophy, known coronary disease, arrhythmia, diabetes mellitus, valvular heart disease) were recorded in 36/194 (18.6%) of the female F+ ECG tests and 249/371 (68.2%) of the male F+ ECG tests (p<0.0001 for the difference). These data suggest that F+ stress ECG tests are frequent and equally common in women and men. However, most F+ stress ECGs in men can be predicted before the test, while most in women cannot. Being female may be a risk factor in itself. These data reinforce the value of stress imaging, particularly in women. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

  19. Associations between social understanding, sibling relationship quality, and siblings' conflict strategies and outcomes.

    PubMed

    Recchia, Holly E; Howe, Nina

    2009-01-01

    Sibling relationship quality and social understanding (second-order false belief, conflict interpretation, and narrative conflict perspective references) were examined as unique and interactive correlates of sibling conflict behavior in 62 dyads (older M age = 8.39 years and younger M age = 6.06 years). High-quality relationships were associated with positive conflict processes. Younger siblings' second-order false belief scores were negatively associated with constructive conflict strategies, and older siblings' narrative self-referential focus was negatively associated with compromise. Associations between younger children's social understanding (conflict interpretation and narrative perspective references) and siblings' dyadic conflict behavior were moderated by relationship quality. Results suggest that links between social understanding and conflict behavior should be considered in conjunction with the quality of children's relationships.

  20. A novel approach to describing and detecting performance anti-patterns

    NASA Astrophysics Data System (ADS)

    Sheng, Jinfang; Wang, Yihan; Hu, Peipei; Wang, Bin

    2017-08-01

    Anti-pattern, as an extension to pattern, describes a widely used poor solution which can bring negative influence to application systems. Aiming at the shortcomings of the existing anti-pattern descriptions, an anti-pattern description method based on first order predicate is proposed. This method synthesizes anti-pattern forms and symptoms, which makes the description more accurate and has good scalability and versatility as well. In order to improve the accuracy of anti-pattern detection, a Bayesian classification method is applied in validation for detection results, which can reduce false negatives and false positives of anti-pattern detection. Finally, the proposed approach in this paper is applied to a small e-commerce system, the feasibility and effectiveness of the approach is demonstrated further through experiments.

  1. Evaluation of usefulness of fine-needle aspiration cytology in the diagnosis of tumours of the accessory parotid gland: a preliminary analysis of a case series in Japan.

    PubMed

    Iguchi, Hiroyoshi; Wada, Tadashi; Matsushita, Naoki; Oishi, Masahiro; Teranishi, Yuichi; Yamane, Hideo

    2014-07-01

    The accuracy and sensitivity of fine-needle aspiration cytology (FNAC) in this analysis were not satisfactory, and the false-negative rate seemed to be higher than for parotid tumours. The possibility of low-grade malignancy should be considered in the surgical treatment of accessory parotid gland (APG) tumours, even if the preoperative results of FNAC suggest that the tumour is benign. Little is known about the usefulness of FNAC in the preoperative evaluation of APG tumours, probably due to the paucity of APG tumour cases. We examined the usefulness of FNAC in the detection of malignant APG tumours. We conducted a retrospective analysis of 3 cases from our hospital, along with 18 previously reported Japanese cases. We compared the preoperative FNAC results with postoperative histopathological diagnoses of APG tumours and evaluated the accuracy, sensitivity, specificity and false-negative rates of FNAC in detecting malignant APG tumours. There were four false-negative cases (19.0%), three of mucoepidermoid carcinomas and one of malignant lymphoma. One false-positive result was noted in the case of a myoepithelioma, which was cytologically diagnosed as suspected adenoid cystic carcinoma. The accuracy, sensitivity and specificity of FNAC in detecting malignant tumours were 76.2%, 60.0% and 90.9%, respectively.

  2. A correlation study of diagnostic fine-needle aspiration with histologic diagnosis in cystic neck lesions.

    PubMed

    Moatamed, Neda A; Naini, Bita V; Fathizadeh, Payman; Estrella, Julie; Apple, Sophia K

    2009-10-01

    The clinical diagnosis of a mass in the neck region encompasses a wide spectrum of differential diagnosis. Fine-needle aspiration is a quick and safe technique, which can provide useful information for initial assessment and further therapeutic measures. The aim of this retrospective study was to evaluate the performance characteristics of the fine-needle aspiration (FNA) in cystic neck lesions. Of 142 patients with FNA for cystic neck masses during 2002-2007, 92 cases were selected with a follow-up histologic diagnosis, excluding the cystic colloid nodule of the thyroid. The cases were divided into salivary gland cystic neck (37 patients) and non-salivary cystic neck (55 patients) mass groups. False-positive and false-negative diagnoses were applied only to the malignant lesions after confirmation by histopathology. In the first group, nine malignant and 28 benign diagnoses were made by FNA; of which three were false-negative. In the second group, there were nine malignant and 46 benign diagnoses with three false negatives. The overall performance of the FNA showed 76% sensitivity and 100% specificity. In conclusion, FNA of the cystic neck lesions offers an invaluable and highly specific initial diagnostic approach for the management of the patients. (c) 2009 Wiley-Liss, Inc.

  3. Comparisons of false negative rates from a trend test alone and from a trend test jointly with a control-high groups pairwise test in the determination of the carcinogenicity of new drugs.

    PubMed

    Lin, Karl K; Rahman, Mohammad A

    2018-05-21

    Interest has been expressed in using a joint test procedure that requires that the results of both a trend test and a pairwise comparison test between the control and the high groups be statistically significant simultaneously at the levels of significance recommended in the FDA 2001 draft guidance for industry document for the separate tests in order for the drug effect on the development of an individual tumor type to be considered as statistically significant. Results of our simulation studies show that there is a serious consequence of large inflations of the false negative rate through large decreases of false positive rate in the use of the above joint test procedure in the final interpretation of the carcinogenicity potential of a new drug if the levels of significance recommended for separate tests are used. The inflation can be as high as 204.5% of the false negative rate when the trend test alone is required to test if the effect is statistically significant. To correct the problem, new sets of levels of significance have also been developed for those who want to use the joint test in reviews of carcinogenicity studies.

  4. RBM10-TFE3 Renal Cell Carcinoma: A Potential Diagnostic Pitfall Due to Cryptic Intrachromosomal Xp11.2 Inversion Resulting in False-negative TFE3 FISH.

    PubMed

    Argani, Pedram; Zhang, Lei; Reuter, Victor E; Tickoo, Satish K; Antonescu, Cristina R

    2017-05-01

    Xp11 translocation renal cell carcinoma (RCC) are defined by chromosome translocations involving the Xp11 breakpoint which results in one of a variety of TFE3 gene fusions. TFE3 break-apart florescence in situ hybridization (FISH) assays are generally preferred to TFE3 immunohistochemistry (IHC) as a means of confirming the diagnosis in archival material, as FISH is less sensitive to the variable fixation which can result in false positive or false negative IHC. Prompted by a case report in the cytogenetics literature, we identify 3 cases of Xp11 translocation RCC characterized by a subtle chromosomal inversion involving the short arm of the X chromosome, resulting in an RBM10-TFE3 gene fusion. TFE3 rearrangement was not detected by conventional TFE3 break-apart FISH, but was suggested by strong diffuse TFE3 immunoreactivity in a clean background. We then developed novel fosmid probes to detect the RBM10-TFE3 gene fusion in archival material. These cases validate RBM10-TFE3 as a recurrent gene fusion in Xp11 translocation RCC, illustrate a source of false-negative TFE3 break-apart FISH, and highlight the complementary role of TFE3 IHC and TFE3 FISH.

  5. Entropies of negative incomes, Pareto-distributed loss, and financial crises.

    PubMed

    Gao, Jianbo; Hu, Jing; Mao, Xiang; Zhou, Mi; Gurbaxani, Brian; Lin, Johnny

    2011-01-01

    Health monitoring of world economy is an important issue, especially in a time of profound economic difficulty world-wide. The most important aspect of health monitoring is to accurately predict economic downturns. To gain insights into how economic crises develop, we present two metrics, positive and negative income entropy and distribution analysis, to analyze the collective "spatial" and temporal dynamics of companies in nine sectors of the world economy over a 19 year period from 1990-2008. These metrics provide accurate predictive skill with a very low false-positive rate in predicting downturns. The new metrics also provide evidence of phase transition-like behavior prior to the onset of recessions. Such a transition occurs when negative pretax incomes prior to or during economic recessions transition from a thin-tailed exponential distribution to the higher entropy Pareto distribution, and develop even heavier tails than those of the positive pretax incomes. These features propagate from the crisis initiating sector of the economy to other sectors.

  6. Clinical Data as an Adjunct to Ultrasound Reduces the False-Negative Malignancy Rate in BI-RADS 3 Breast Lesions

    PubMed Central

    Ackermann, S.; Schoenenberger, C.-A.; Zanetti-Dällenbach, R.

    2016-01-01

    Purpose: Ultrasound (US) is a well-established diagnostic procedure for breast examination. We investigated the malignancy rate in solid breast lesions according to their BI-RADS classification with a particular focus on false-negative BI-RADS 3 lesions. We examined whether patient history and clinical findings could provide additional information that would help determine further diagnostic steps in breast lesions. Materials and Methods: We conducted a retrospective study by exploring US BI-RADS in 1469 breast lesions of 1201 patients who underwent minimally invasive breast biopsy (MIBB) from January 2002 to December 2011. Results: The overall sensitivity and specificity of BI-RADS classification was 97.4% and 66.4%, respectively, with a positive (PPV) and negative predictive value (NPV) of 65% and 98%, respectively. In 506 BI-RADS 3 lesions, histology revealed 15 malignancies (2.4% malignancy rate), which corresponds to a false-negative rate (FNR) of 2.6%. Clinical evaluation and patient requests critically influenced the further diagnostic procedure, thereby prevailing over the recommendation given by the BI-RADS 3 classification. Conclusion: Clinical criteria including age, family and personal history, clinical examination, mammography and patient choice ensure adequate diagnostic procedures such as short-term follow-up or MIBB in patients with lesions classified as US-BI-RADS 3. PMID:27689181

  7. Characterization and Identification of Productivity-Associated Rhizobacteria in Wheat

    PubMed Central

    Habiger, Joshua

    2012-01-01

    The rhizosphere is populated by a numerous and diverse array of rhizobacteria, and many impact productivity in largely unknown ways. Here we characterize the rhizobacterial community in a wheat variety categorized according to shoot biomass using 16S rRNA pyrosequencing abundance data. Plants were grown in homogenized field soil under greenhouse conditions, and DNA was extracted and pyrosequenced, resulting in 29,007 quality sequences. Operational taxonomic units (OTUs) that were significantly associated with biomass productivity were identified using an exact test adjusted for the false-discovery rate. The productivity deviation expressed as a percentage of the total mean square for regression (PMSR) was determined for each OTU. Out of 719 OTUs, 42 showed significant positive associations and 39 showed significant negative associations (q value, ≤0.05). OTUs with the greatest net positive associations, by genus, were as follows: Duganella, OTU 43 and OTU 3; Janthinobacterium, OTU 278; Pseudomonas, OTU 588; and Cellvibrio, OTU 1847. Those with negative associations were as follows: Bacteria, OTU 273; Chryseobacterium, OTU 508; Proteobacteria, OTU 249; and Enterobacter, OTU 357. Shoot biomass productivity was strongly correlated with the balance between the overall abundances of positive- and negative-productivity-associated OTUs. High-productivity rhizospheres contained 9.2 significant positives for every negatively associated rhizobacterium, while low-productivity rhizospheres showed 2.3 significant negatives for every positively associated rhizobacterium. Overall rhizobacterial community diversity as measured by the Chao1, Shannon, and Simpson indexes was nonlinearly related to productivity, closely fitting a wavelike cubic equation. We conclude that shoot biomass productivity is strongly related to the ratio of positive- to negative-productivity-associated rhizobacteria in the rhizosphere. This study identifies significant OTUs composing the productive and unproductive rhizobacterial communities. PMID:22504815

  8. Reducing False Positives in Runtime Analysis of Deadlocks

    NASA Technical Reports Server (NTRS)

    Bensalem, Saddek; Havelund, Klaus; Clancy, Daniel (Technical Monitor)

    2002-01-01

    This paper presents an improvement of a standard algorithm for detecting dead-lock potentials in multi-threaded programs, in that it reduces the number of false positives. The standard algorithm works as follows. The multi-threaded program under observation is executed, while lock and unlock events are observed. A graph of locks is built, with edges between locks symbolizing locking orders. Any cycle in the graph signifies a potential for a deadlock. The typical standard example is the group of dining philosophers sharing forks. The algorithm is interesting because it can catch deadlock potentials even though no deadlocks occur in the examined trace, and at the same time it scales very well in contrast t o more formal approaches to deadlock detection. The algorithm, however, can yield false positives (as well as false negatives). The extension of the algorithm described in this paper reduces the amount of false positives for three particular cases: when a gate lock protects a cycle, when a single thread introduces a cycle, and when the code segments in different threads that cause the cycle can actually not execute in parallel. The paper formalizes a theory for dynamic deadlock detection and compares it to model checking and static analysis techniques. It furthermore describes an implementation for analyzing Java programs and its application to two case studies: a planetary rover and a space craft altitude control system.

  9. Utility of galactomannan antigen detection in bronchoalveolar lavage fluid in immunocompromised patients.

    PubMed

    Brownback, Kyle R; Pitts, Lucas R; Simpson, Steven Q

    2013-09-01

    Diagnosis of invasive pulmonary aspergillosis (IPA) is a challenging process in immunocompromised patients. Galactomannan (GM) antigen detection in bronchoalveolar lavage (BAL) fluid is a method to detect IPA with improved sensitivity over conventional studies. We sought to determine the diagnostic yield of BAL GM assay in a diverse population of immunocompromised patients. A retrospective review of 150 fiberoptic bronchoscopy (FOB) with BAL for newly diagnosed pulmonary infiltrate in immunocompromised patients was performed. Patient information, procedural details and laboratory studies were collected. BAL and serum samples were evaluated for GM using enzyme-linked immunoassay. Of 150 separate FOB with BAL, BAL GM was obtained in 143 samples. There were 31 positive BAL GM assays. In those 31 positive tests, 13 were confirmed as IPA, giving a positive predictive value of 41.9%. There was one false negative BAL GM. Of the 18 false positive BAL GM, 4 were receiving piperacillin-tazobactam and 11 were receiving an alternative beta-lactam antibiotic. BAL GM assay shows excellent sensitivity for diagnosing IPA. There was a significant number of false positive BAL GM assays and several of those patients were receiving beta-lactam antibiotics at the time of bronchoscopy. © 2013 Blackwell Verlag GmbH.

  10. Lupus erythematosus cell preparation, antinuclear factor and antideoxyribonucleic acid antibody incongruity in systemic lupus erythematosus.

    PubMed

    Chee, Y C

    1983-01-01

    'Total antinuclear antibody' (ANF) is detected by the fluorescent antinuclear antibody technique which is a screening test, positive in 99% of systemic lupus erythematosus (SLE) sera. The LE factor (positive in 75% of SLE sera), like the anti-DNA antibody, is an antinuclear antibody but directed against DNA-histone. ANF-negative SLE is a clinical entity with absence of these antibodies. A false negative ANF, in the presence of high titre anti-DNA antibody and/or LE cells, is illustrated in two cases of SLE. Postulated mechanisms for this phenomenon are interference in ANF detection by rheumatoid factor, and the prozone effect on the immunofluorescent tests.

  11. Pluto behaving badly: false beliefs and their consequences.

    PubMed

    Berkowitz, Shari R; Laney, Cara; Morris, Erin K; Garry, Maryanne; Loftus, Elizabeth F

    2008-01-01

    We exposed college students to suggestive materials in order to lead them to believe that, as children, they had a negative experience at Disneyland involving the Pluto character. A sizable minority of subjects developed a false belief or memory that Pluto had uncomfortably licked their ear. Suggestions about a positive experience with Pluto led to even greater acceptance of a lovable ear-licking episode. False beliefs and memories had repercussions; those seduced by the bad suggestions were not willing to pay as much for a Pluto souvenir. These findings are among the first to demonstrate that false beliefs can have repercussions for people, meaning that they can influence their later thoughts, beliefs, and behaviors.

  12. 14 CFR 25.255 - Out-of-trim characteristics.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Out-of-trim characteristics. 25.255 Section 25.255 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... the positive and negative values specified in paragraph (c) of this section— (1) The stick force vs. g...

  13. 14 CFR 25.255 - Out-of-trim characteristics.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Out-of-trim characteristics. 25.255 Section 25.255 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... the positive and negative values specified in paragraph (c) of this section— (1) The stick force vs. g...

  14. Avoiding false positives and optimizing identification of true negatives in estrogen receptor binding and agonist/antagonist assays

    EPA Science Inventory

    The potential for chemicals to affect endocrine signaling is commonly evaluated via in vitro receptor binding and gene activation, but these assays, especially antagonism assays, have potential artifacts that must be addressed for accurate interpretation. Results are presented fr...

  15. 14 CFR 29.177 - Static directional stability.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Static directional stability. 29.177... Static directional stability. (a) The directional controls must operate in such a manner that the sense... versus directional control position curve may have a negative slope within a small range of angles around...

  16. 14 CFR 27.177 - Static directional stability.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Static directional stability. 27.177... directional stability. (a) The directional controls must operate in such a manner that the sense and direction... sideslip angle versus directional control position curve may have a negative slope within a small range of...

  17. ALK status testing in non-small cell lung carcinoma: correlation between ultrasensitive IHC and FISH.

    PubMed

    Minca, Eugen C; Portier, Bryce P; Wang, Zhen; Lanigan, Christopher; Farver, Carol F; Feng, Yan; Ma, Patrick C; Arrossi, Valeria A; Pennell, Nathan A; Tubbs, Raymond R

    2013-05-01

    ALK gene rearrangements in advanced non-small cell lung carcinomas (NSCLC) are an indication for targeted therapy with crizotinib. Fluorescence in situ hybridization (FISH) using a recently approved companion in vitro diagnostic class FISH system commonly assesses ALK status. More accessible IHC is challenged by low expression of ALK-fusion transcripts in NSCLC. We compared ultrasensitive automated IHC with FISH for detecting ALK status on 318 FFPE and 40 matched ThinPrep specimens from 296 patients with advanced NSCLC. IHC was concordant with FFPE-FISH on 229 of 231 dual-informative samples (31 positive and 198 negative) and with ThinPrep-FISH on 34 of 34 samples (5 positive and 29 negative). Two cases with negative IHC and borderline-positive FFPE-FISH (15% and 18%, respectively) were reclassified as concordant based on negative matched ThinPrep-FISH and clinical data consistent with ALK-negative status. Overall, after including ThinPrep-FISH and amending the false-positive FFPE-FISH results, IHC demonstrated 100% sensitivity and specificity (95% CI, 0.86 to 1.00 and 0.97 to 1.00, respectively) for ALK detection on 249 dual-informative NSCLC samples. IHC was informative on significantly more samples than FFPE-FISH, revealing additional ALK-positive cases. The high concordance with FISH warrants IHC's routine use as the initial component of an algorithmic approach to clinical ALK testing in NSCLC, followed by reflex FISH confirmation of IHC-positive cases. Copyright © 2013 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  18. Hilbertian sine as an absolute measure of Bayesian inference in ISR, homeland security, medicine, and defense

    NASA Astrophysics Data System (ADS)

    Jannson, Tomasz; Wang, Wenjian; Hodelin, Juan; Forrester, Thomas; Romanov, Volodymyr; Kostrzewski, Andrew

    2016-05-01

    In this paper, Bayesian Binary Sensing (BBS) is discussed as an effective tool for Bayesian Inference (BI) evaluation in interdisciplinary areas such as ISR (and, C3I), Homeland Security, QC, medicine, defense, and many others. In particular, Hilbertian Sine (HS) as an absolute measure of BI, is introduced, while avoiding relativity of decision threshold identification, as in the case of traditional measures of BI, related to false positives and false negatives.

  19. A biopsymeter to support the diagnostic procedure of skin samples

    NASA Astrophysics Data System (ADS)

    Fioravanti, Valeria; Chandrashekar, Shailendra; Brandhoff, Lukas; Pucciarelli, Daniela; van den Driesche, Sander; Breiteneder, Heimo; Hafner, Christine; Vellekoop, Michael J.

    2015-06-01

    We present an infrared biopsymeter to assist pathologists in the diagnosis of melanoma presence in skin biopsies. The designed and realized system combines the features of visual inspection and physical sensing to reduce false positives and false negatives occurring during standard histopathological analyses. The biopsymeter determines the CH2-stretch ratio by infrared absorbance measurements of skin biopsies. Investigations conducted with the biopsymeter shows that malignant melanomas and melanoma metastases have higher CH2-stretch ratio values compared to healthy skin tissues.

  20. Present Concepts in Internal Medicine. Volume 13, Number 1. Endocrinology Research Symposium,

    DTIC Science & Technology

    1980-01-01

    Liddle suppression test in which dexamethasone 0.5 mg q6h (2 mg/day) is given for two days with collection of urine 17-OHCS. 3 Confirmation of the...diagnosis is best established by measurement of urine free cortisol which has the advantage of not being elevated in obesity.4 False negatives occur in 10...experience (in the absence of conditions causing false positive responses) the presence of elevated urine free cortisol (> 100 Vg/24 h) and lack of

Top