Sample records for post ivc engine

  1. Improving the retrieval rate of inferior vena cava filters with a multidisciplinary team approach

    PubMed Central

    Inagaki, Elica; Farber, Alik; Eslami, Mohammad H.; Siracuse, Jeffrey J.; Rybin, Denis V.; Sarosiek, Shayna; Sloan, J. Mark; Kalish, Jeffrey

    2017-01-01

    Objective The option to retrieve inferior vena cava (IVC) filters has resulted in an increase in the utilization of these devices as stopgap measures in patients with relative contraindications to anticoagulation. These retrievable IVC filters, however, are often not retrieved and become permanent. Recent data from our institution confirmed a historically low retrieval rate. Therefore, we hypothesized that the implementation of a new IVC filter retrieval protocol would increase the retrieval rate of appropriate IVC filters at our institution. Methods All consecutive patients who underwent an IVC filter placement at our institution between September 2003 and July 2012 were retrospectively reviewed. In August 2012, a multidisciplinary task force was established, and a new IVC filter retrieval protocol was implemented. Prospective data were collected using a centralized interdepartmental IVC filter registry for all consecutive patients who underwent an IVC filter placement between August 2012 and September 2014. Patients were chronologically categorized into preimplementation (PRE) and postimplementation (POST) groups. Comparisons of outcome measures, including the retrieval rate of IVC filters along with rates of retrieval attempt and technical failure, were made between the two groups. Results In the PRE and POST groups, a total of 720 and 74 retrievable IVC filters were implanted, respectively. In the POST group, 40 of 74 filters (54%) were successfully retrieved compared with 82 of 720 filters (11%) in the PRE group (P < .001). Furthermore, a greater number of IVC filter retrievals were attempted in the POST group than in the PRE group (66% vs 14%; P < .001). No significant difference was observed between the PRE and POST groups for technical failure (17% vs 18%; P = .9). Conclusions The retrieval rate of retrievable IVC filters at our institution was significantly increased with the implementation of a new IVC filter retrieval protocol with a multidisciplinary team approach. This improved retrieval rate is possible with minimal dedication of resources and can potentially lead to a decrease in IVC filter-related complications in the future. PMID:27318045

  2. Improving the retrieval rate of inferior vena cava filters with a multidisciplinary team approach.

    PubMed

    Inagaki, Elica; Farber, Alik; Eslami, Mohammad H; Siracuse, Jeffrey J; Rybin, Denis V; Sarosiek, Shayna; Sloan, J Mark; Kalish, Jeffrey

    2016-07-01

    The option to retrieve inferior vena cava (IVC) filters has resulted in an increase in the utilization of these devices as stopgap measures in patients with relative contraindications to anticoagulation. These retrievable IVC filters, however, are often not retrieved and become permanent. Recent data from our institution confirmed a historically low retrieval rate. Therefore, we hypothesized that the implementation of a new IVC filter retrieval protocol would increase the retrieval rate of appropriate IVC filters at our institution. All consecutive patients who underwent an IVC filter placement at our institution between September 2003 and July 2012 were retrospectively reviewed. In August 2012, a multidisciplinary task force was established, and a new IVC filter retrieval protocol was implemented. Prospective data were collected using a centralized interdepartmental IVC filter registry for all consecutive patients who underwent an IVC filter placement between August 2012 and September 2014. Patients were chronologically categorized into preimplementation (PRE) and postimplementation (POST) groups. Comparisons of outcome measures, including the retrieval rate of IVC filters along with rates of retrieval attempt and technical failure, were made between the two groups. In the PRE and POST groups, a total of 720 and 74 retrievable IVC filters were implanted, respectively. In the POST group, 40 of 74 filters (54%) were successfully retrieved compared with 82 of 720 filters (11%) in the PRE group (P < .001). Furthermore, a greater number of IVC filter retrievals were attempted in the POST group than in the PRE group (66% vs 14%; P < .001). No significant difference was observed between the PRE and POST groups for technical failure (17% vs 18%; P = .9). The retrieval rate of retrievable IVC filters at our institution was significantly increased with the implementation of a new IVC filter retrieval protocol with a multidisciplinary team approach. This improved retrieval rate is possible with minimal dedication of resources and can potentially lead to a decrease in IVC filter-related complications in the future. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  3. Vena Cava Filter Retrieval with Aorto-Iliac Arterial Strut Penetration.

    PubMed

    Holly, Brian P; Gaba, Ron C; Lessne, Mark L; Lewandowski, Robert J; Ryu, Robert K; Desai, Kush R; Sing, Ronald F

    2018-05-03

    To evaluate the safety and technical success of inferior vena cava (IVC) filter retrieval in the setting of aorto-iliac arterial strut penetration. IVC filter registries from six large United States IVC filter retrieval practices were retrospectively reviewed to identify patients who underwent IVC filter retrieval in the setting of filter strut penetration into the adjacent aorta or iliac artery. Patient demographics, implant duration, indication for placement, IVC filter type, retrieval technique and technical success, adverse events, and post procedural clinical outcomes were identified. Arterial penetration was determined based on pre-procedure CT imaging in all cases. The IVC filter retrieval technique used was at the discretion of the operating physician. Seventeen patients from six US centers who underwent retrieval of an IVC filter with at least one strut penetrating either the aorta or iliac artery were identified. Retrieval technical success rate was 100% (17/17), without any major adverse events. Post-retrieval follow-up ranging from 10 days to 2 years (mean 4.6 months) was available in 12/17 (71%) patients; no delayed adverse events were encountered. Findings from this series suggest that chronically indwelling IVC filters with aorto-iliac arterial strut penetration may be safely retrieved.

  4. Late endovascular removal of Günther-Tulip inferior vena cava filter and stent reconstruction of chronic post-thrombotic iliocaval obstruction after 4753 days of filter dwell time: a case report with review of literature.

    PubMed

    Doshi, Mehul Harshad; Narayanan, Govindarajan

    2016-12-01

    Chronic post-thrombotic obstruction of the inferior vena cava (IVC) or iliocaval junction is an uncommon complication of long indwelling IVC filter. When such an obstruction is symptomatic, endovascular treatment options include stent placement with or without filter retrieval. Filter retrieval becomes increasingly difficult with longer dwell times. We present a case of symptomatic post-thrombotic obstruction of the iliocaval junction related to Günther-Tulip IVC filter (Cook Medical Inc, Bloomington, IN) with dwell time of 4753 days, treated successfully with endovascular filter removal and stent reconstruction. Filter retrieval and stent reconstruction may be a treatment option in symptomatic patients with filter-related chronic IVC or iliocaval junction obstruction, even after prolonged dwell time.

  5. Post traumatic inferior vena cava thrombosis: A case report and review of literature.

    PubMed

    Chakroun, Amine; Nakhli, Mohamed Said; Kahloul, Mohamed; Harrathi, Mohamed Amine; Naija, Walid

    2017-01-01

    Post traumatic inferior vena cava (IVC) thrombosis is a rare and not well described entity with nonspecific clinical presentation. It remains a therapeutic challenge in traumatic context because of haemorrhagic risk due to anticoagulation. We report a case of IVC thrombosis in an 18 year-old man who presented with liver injury following a traffic crash. The thrombosis was incidentally diagnosed on admission by computed tomography. The patient was managed conservatively without anticoagulation initially considering the increasing haemorrhagic risk. IVC filter placing was not possible because of the unusual localization of the thrombus. Unfractionated heparin was started on the third day after CT scan control showing stability of hepatic lesions with occurrence of a pulmonary embolism. The final outcome was good. The management of post traumatic IVC thrombosis is not well described. Medical approach consists in conservative management with anticoagulation which requires the absence of active bleeding lesions. Surgical treatment is commonly based on thrombectomy under extracorporeal circulation. Interventional vascular techniques have become an important alternative approach for the treatment of many vessel lesions. Their main advantages are the relative ease and speed with which they can be performed. Post traumatic IVC thrombosis is a rare condition. Its management is not well defined. Early anticoagulation should be discussed on a case-by-case basis. Other alternatives such IVC filter or surgical thrombectomy may be used when the bleeding risk is increased. The most serious risk is pulmonary embolism. Outcome can be favorable even with non surgical approaches. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Establishment of an inferior vena cava filter database and interventional radiology led follow-up - retrieval rates and patients lost to follow-up.

    PubMed

    Klinken, Sven; Humphries, Charlotte; Ferguson, John

    2017-10-01

    To evaluate the rates of inferior vena cava (IVC) filter retrieval and the number of patient's lost to follow-up, before and after the establishment of an IVC filter database and interventional radiology (inserting physician) led follow-up. On the 1st of June 2012, an electronic interventional radiology database was established at our Institution. In addition, the interventional radiology team took responsibility for follow-up of IVC filters. Data were prospectively collected from the database for all patients who had an IVC filter inserted between the 1st June 2012 and the 31st May 2014. Data on patients who had an IVC filter inserted between the 1st of June 2009 to the 31st of May 2012 were retrospectively reviewed. Patient demographics, insertion indications, filter types, retrieval status, documented retrieval decisions, time in situ, trackable events and complications were obtained in the pre-database (n = 136) and post-database (n = 118) cohorts. Attempted IVC filter retrieval rates were improved from 52.9% to 72.9% (P = 0.001) following the establishment of the database. The number of patients with no documented decision (lost to follow-up) regarding their IVC filter reduced from 31 of 136 (23%) to 0 of 118 patients (P = < 0.001). There was a non-significant reduction in IVC filter dwell time in the post-database group (113 as compared to 137 days, P = 0.129). Following the establishment of an IVC filter database and interventional radiology led follow-up, we demonstrate a significant improvement in the attempted retrieval rates of IVC filters and the number of patient's lost to follow-up. © 2017 The Royal Australian and New Zealand College of Radiologists.

  7. Case of a Misplaced IVC Filter: A Lesson to Learn

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharma, Sanjay, E-mail: drssharma@hotmail.com; Mukund, Amar, E-mail: dramarmukund@gmail.co; Agarwal, Sandeep, E-mail: sandeep_aiims@yahoo.co.i

    2010-08-15

    The inferior vena cava (IVC) filter insertion is a well established procedure to prevent significant pulmonary embolism in selected situations. It is generally considered straight forward without significant complications. We report an interesting case of a young postpartum woman in whom an IVC filter was misplaced in the right gonadal vein. This complication is only rarely reported. Presence of prominent right gonadal vein must always be kept in mind during trans-jugular placement of infra renal filter in the IVC in post partum women.

  8. High-dose intravenous vitamin C combined with cytotoxic chemotherapy in patients with advanced cancer: a phase I-II clinical trial.

    PubMed

    Hoffer, L John; Robitaille, Line; Zakarian, Robert; Melnychuk, David; Kavan, Petr; Agulnik, Jason; Cohen, Victor; Small, David; Miller, Wilson H

    2015-01-01

    Biological and some clinical evidence suggest that high-dose intravenous vitamin C (IVC) could increase the effectiveness of cancer chemotherapy. IVC is widely used by integrative and complementary cancer therapists, but rigorous data are lacking as to its safety and which cancers and chemotherapy regimens would be the most promising to investigate in detail. We carried out a phase I-II safety, tolerability, pharmacokinetic and efficacy trial of IVC combined with chemotherapy in patients whose treating oncologist judged that standard-of-care or off-label chemotherapy offered less than a 33% likelihood of a meaningful response. We documented adverse events and toxicity associated with IVC infusions, determined pre- and post-chemotherapy vitamin C and oxalic acid pharmacokinetic profiles, and monitored objective clinical responses, mood and quality of life. Fourteen patients were enrolled. IVC was safe and generally well tolerated, although some patients experienced transient adverse events during or after IVC infusions. The pre- and post-chemotherapy pharmacokinetic profiles suggested that tissue uptake of vitamin C increases after chemotherapy, with no increase in urinary oxalic acid excretion. Three patients with different types of cancer experienced unexpected transient stable disease, increased energy and functional improvement. Despite IVC's biological and clinical plausibility, career cancer investigators currently ignore it while integrative cancer therapists use it widely but without reporting the kind of clinical data that is normally gathered in cancer drug development. The present study neither proves nor disproves IVC's value in cancer therapy, but it provides practical information, and indicates a feasible way to evaluate this plausible but unproven therapy in an academic environment that is currently uninterested in it. If carried out in sufficient numbers, simple studies like this one could identify specific clusters of cancer type, chemotherapy regimen and IVC in which exceptional responses occur frequently enough to justify appropriately focused clinical trials. ClinicalTrials.gov NCT01050621.

  9. Modification and performance evaluation of a mono-valve engine

    NASA Astrophysics Data System (ADS)

    Behrens, Justin W.

    A four-stroke engine utilizing one tappet valve for both the intake and exhaust gas exchange processes has been built and evaluated. The engine operates under its own power, but has a reduced power capacity than the conventional 2-valve engine. The reduction in power is traced to higher than expected amounts of exhaust gases flowing back into the intake system. Design changes to the cylinder head will fix the back flow problems, but the future capacity of mono-valve engine technology cannot be estimated. The back flow of exhaust gases increases the exhaust gas recirculation (EGR) rate and deteriorates combustion. Intake pressure data shows the mono-valve engine requires an advanced intake valve closing (IVC) time to prevent back flow of charge air. A single actuation camshaft with advanced IVC was tested in the mono-valve engine, and was found to improve exhaust scavenging at TDC and nearly eliminated all charge air back flow at IVC. The optimum IVC timing is shown to be approximately 30 crank angle degrees after BDC. The mono-valve cylinder head utilizes a rotary valve positioned above the tappet valve. The open spaces inside the rotary valveand between the rotary valve and tappet valve represent a common volume that needs to be reduced in order to reduce the base EGR rate. Multiple rotary valve configurations were tested, and the size of the common volume was found to have no effect on back flow but a direct effect on the EGR rate and engine performance. The position of the rotary valve with respect to crank angle has a direct effect on the scavenging process. Optimum scavenging occurs when the intake port is opened just after TDC.

  10. Statewide Inferior Vena Cava Filter Placement, Complications, and Retrievals: Epidemiology and Recent Trends.

    PubMed

    Charalel, Resmi A; Durack, Jeremy C; Mao, Jialin; Ross, Joseph S; Meltzer, Andrew J; Sedrakyan, Art

    2018-03-01

    Public awareness of inferior vena cava (IVC) filter-related controversies has been elevated by the Food and Drug Administration (FDA) safety communication in 2010. To examine population level trends in IVC filter utilization, complications, retrieval rates, and subsequent pulmonary embolism (PE) risk. A retrospective cohort study. Patients receiving IVC filters during 2005-2014 in New York State. IVC filter-specific complications, new PE occurrences and IVC filter retrievals were evaluated as time-to-event data using Kaplan-Meier analysis. Estimated cumulative risks were obtained at various timepoints during follow-up. There were 91,873 patients receiving IVC filters between 2005 and 2014 in New York State included in the study. The average patient age was 67 years and 46.6% were male. Age-adjusted rates of IVC filter placement increased from 48 cases/100,000 in 2005 to 52 cases/100,000 in 2009, and decreased afterwards to 36 cases/100,000 in 2014. The estimated risks of having an IVC filter-related complication and filter retrieval within 1 year was 1.5% [95% confidence interval (CI), 1.4%-1.6%] and 3.5% (95% CI, 3.4%-3.6%). One-year retrieval rate was higher post-2010 when compared with pre-2010 years (hazard ratio, 2.70; 95% CI, 2.50-2.91). Among the 58,176 patients who did not have PE events before or at the time of IVC filter placement, the estimated risk of developing subsequent PE at 1 year was 2.0% (95% CI, 1.9%-2.1%). Our findings suggest that FDA communications may be effective in modifying statewide clinical practices. Given the 2% observed PE rate following prophylactic IVC filter placement, large scale pragmatic studies are needed to determine contemporary safety and effectiveness of IVC filters.

  11. Behavioural consequences of IVC cages on male and female C57BL/6J mice.

    PubMed

    Logge, W; Kingham, J; Karl, T

    2013-05-01

    Recent developments in the technology to breed and house laboratory rodents for medical research has produced individually ventilated cage (IVC) systems. These IVC systems produce a cage environment significantly different to conventional cages. As it is not known in detail whether housing mice in IVCs impacts on their baseline and drug-induced behaviours compared to mice of conventional filter-top cages a comprehensive multi-tiered phenotyping strategy was used to test the behavioural consequences of IVC housing in male and female C57BL/6JArc mice. IVC had anxiety-like effects in the elevated plus maze, which were more pronounced in female mice whereas cognition and locomotion of all test mice were not modified by IVC housing. Mice raised in IVC cage systems were socially more active than mice of filter-top systems. Furthermore, males raised in IVC exhibited an increased sensitivity to the locomotor-stimulating effects of acute MK-801 treatment compared to males in conventional cages. In summary, this is the first study revealing the longer-term effects of IVC housing on social behaviours and the locomotor response to an acute MK-801 challenge. In conclusion, researchers upgrading their holding facilities to IVC housing may encounter a shift in experimental outcomes (e.g. post pharmacological challenges) and the behavioural phenotype of test mice. Furthermore, differences between the housing conditions of breeding facilities and test facilities must carefully be considered. Finally, researchers should clarify in detail the type of housing test animals have been exposed to when publishing experimental animal research data. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.

  12. Preliminary evaluation of magnetic resonance fresh blood imaging for diagnosis of Budd-Chiari syndrome.

    PubMed

    Ren, Ke; Xu, Ke; Sun, Wen-ge; Chen, Yu-shuai; Qi, Xi-xun; Li, Ran-liang; Jin, An-yu

    2007-01-20

    Budd-Chiari syndrome (BCS) is a rare disease with portal hypertension caused by the blockage of the hepatic vein and/or the inferior vena cava (IVC). Angiography is the "golden standard" for diagnosis, but it is an invasive examination. To assess the diagnostic value of a fresh blood imaging (FBI) relative to BCS, we used a magnetic resonance angiography (MRA) with an FBI sequence for a preoperative evaluation of the BCS patients in this study. Fifty patients who were suspected of having BCS after they had been checked by a B-ultrasound were studied. 2D and 3D FBI were performed on a 1.5T superconductive MR scanner. Original images were rebuilt using a maximal intensity projection (MIP) method on the console. Two doctors reviewed all images before they learned of the angiography results. We then compared the diagnoses obtained from the FBI and angiography results to evaluate the diagnostic value of the FBI. Forty-one patients were diagnosed as BCS and 9 as non-BCS based on an angiography. The FBI correctly diagnosed 38 patients, incorrectly diagnosed 1 patient, and missed diagnosis in 3 patients. Thus, the diagnostic sensitivity of the FBI is 93% (38/41), the specificity is 89% (8/9) and the accuracy is 92% (46/50). The FBI images of the 13 membranous stenoses of the IVC showed a sudden stenosis of the post-liver segment of the IVC. The Images of the 5 patients with a membranous obstruction of the IVC showed IVC thickening and an absence of blood signals in the post-hepatic segment of the IVC. The images of the 4 patients with the segmental thrombosis of the IVC showed abnormal and intermittent signals in the IVC. The images of the 6 patients with a simple hepatic vein obstruction showed obstructive hepatic veins. The images of the 6 patients with the stenosis of both the IVC and the hepatic veins showed the stenosis of the IVC, the thickening of the hepatic veins and the formation of a compensatory circulation within the liver. Lastly, the images of the 7 patients showed a combination of the IVC thrombosis with stenosis or with the obstruction of one or two hepatic veins. An FBI can show a membranous stenosis, and an obstruction and thrombosis of the IVC. In addition, it can also demonstrate the thickening of the flexural hepatic vein and the development of intra-hepatic compensatory branches with slow blood flow. Thus, it can guide the puncturing and opening of the hepatic vein involved in an interventional therapy for BCS patients.

  13. Chemoembolization and stenting combined with iodine-125 seed strands for the treatment of hepatocellular carcinoma with inferior vena cava obstruction

    PubMed Central

    LI, WENHUI; DAI, ZHENYU; YAO, LIZHENG; LUO, JIANJUN; YAN, ZHIPING

    2015-01-01

    The aim of the present study was to investigate the efficacy and safety of stenting combined with radioactive iodine-125 seed strands following chemoembolization for the treatment of patients with hepatocellular carcinoma and inferior vena cava (IVC) obstruction. A retrospective analysis was conducted of 52 hepatocellular carcinoma patients with IVC obstruction. All patients received chemoembolization of tumor-supplying arteries and IVC stents, and 18 patients additionally received iodine-125 seed strands, which were fixed to the stents. Improvement of IVC obstruction and the tumor response rates were compared between the two groups with a median follow-up time of 2.5 months. In both groups the stents were successfully deployed. At the 2-month post-procedural follow-up, the mean diameter of the IVC obstruction site, the mean pressure difference between the distal IVC obstructive segment and the right atrium as well as the obstruction scoring did not differ significantly between the two groups. By contrast, the tumor response rate of the iodine-125 seed strand group was 94.4%, whereas for the group without iodine-125 seed strands it was 35.3% (P<0.001). The combination of stent and iodine-125 seed strands was effective and safe for the treatment of hepatocellular carcinoma with IVC obstruction. PMID:26622424

  14. Complications of inferior vena cava filters

    PubMed Central

    Grewal, Simer; Chamarthy, Murthy R.

    2016-01-01

    Inferior vena cava (IVC) filter placement is a relatively low risk alternative for prophylaxis against pulmonary embolism in patients with pelvic or lower extremity deep venous thrombosis who are not suitable for anticoagulation. There is an increasing trend in the number of IVC filter implantation procedures performed every year. There are many device types in the market and in the early 2000s, the introduction of retrievable filters brought an additional subset of complications to consider. Modern filter designs have led to decreased morbidity and mortality, however, a thorough understanding of the limitations and complications of IVC filters is necessary to weight the risks and benefits of placing IVC filters. In this review, the complications associated with IVC filters are divided into procedure related, post-procedure, and retrieval complications. Differences amongst the device types and retrievable filters are described, though this is limited by a significant lack of prospective studies. Additionally, the clinical presentation as well as prevention and treatment strategies are outlined with each complication type. PMID:28123983

  15. High-Dose Intravenous Vitamin C Combined with Cytotoxic Chemotherapy in Patients with Advanced Cancer: A Phase I-II Clinical Trial

    PubMed Central

    Hoffer, L. John; Robitaille, Line; Zakarian, Robert; Melnychuk, David; Kavan, Petr; Agulnik, Jason; Cohen, Victor; Small, David; Miller, Wilson H.

    2015-01-01

    Background Biological and some clinical evidence suggest that high-dose intravenous vitamin C (IVC) could increase the effectiveness of cancer chemotherapy. IVC is widely used by integrative and complementary cancer therapists, but rigorous data are lacking as to its safety and which cancers and chemotherapy regimens would be the most promising to investigate in detail. Methods and Findings We carried out a phase I-II safety, tolerability, pharmacokinetic and efficacy trial of IVC combined with chemotherapy in patients whose treating oncologist judged that standard-of-care or off-label chemotherapy offered less than a 33% likelihood of a meaningful response. We documented adverse events and toxicity associated with IVC infusions, determined pre- and post-chemotherapy vitamin C and oxalic acid pharmacokinetic profiles, and monitored objective clinical responses, mood and quality of life. Fourteen patients were enrolled. IVC was safe and generally well tolerated, although some patients experienced transient adverse events during or after IVC infusions. The pre- and post-chemotherapy pharmacokinetic profiles suggested that tissue uptake of vitamin C increases after chemotherapy, with no increase in urinary oxalic acid excretion. Three patients with different types of cancer experienced unexpected transient stable disease, increased energy and functional improvement. Conclusions Despite IVC’s biological and clinical plausibility, career cancer investigators currently ignore it while integrative cancer therapists use it widely but without reporting the kind of clinical data that is normally gathered in cancer drug development. The present study neither proves nor disproves IVC’s value in cancer therapy, but it provides practical information, and indicates a feasible way to evaluate this plausible but unproven therapy in an academic environment that is currently uninterested in it. If carried out in sufficient numbers, simple studies like this one could identify specific clusters of cancer type, chemotherapy regimen and IVC in which exceptional responses occur frequently enough to justify appropriately focused clinical trials. Trial Registration ClinicalTrials.gov NCT01050621 PMID:25848948

  16. Mechanisms of Günther Tulip filter tilting during transfemoral placement.

    PubMed

    Matsui, Y; Horikawa, M; Ohta, K; Jahangiri Noudeh, Y; Kaufman, J A; Farsad, K

    The purpose of this study was to characterize the mechanisms of Günther Tulip filter (GTF) tilting during transfemoral placement in an experimental model with further validation in a clinical series. In an experimental study, 120 GTF placements in an inferior vena cava (IVC) model were performed using 6 configurations of pre-deployment filter position. The angle between the pre-deployment filter axis and IVC axis, and the proximity of the constrained filter legs to IVC wall prior to deployment were evaluated. The association of those pre-deployment factors with post-deployment filter tilting was analyzed. The association noted in the experimental study was then evaluated in a retrospective clinical series of 21 patients. In the experimental study, there was a significant association between the pre-deployment angle and post-deployment filter tilting (P<0.0001). With a low pre-deployment angle (≤5°), a significant association was noted between filter tilting and the proximity of the constrained filter legs to the far IVC wall (P=0.001). In a retrospective clinical study, a significant association between the pre-deployment angle and post-deployment filter tilting was also noted with a linear regression model (P=0.026). Significant association of the pre-deployment angle with post-deployment GTF tilting was shown in both the experimental and clinical studies. The experimental study also showed that proximity of filter legs is relevant when pre-deployment angle is small. Addressing these factors may result in a lower incidence of filter tilting. Copyright © 2017 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  17. Modeling and control of fuel distribution in a dual-fuel internal combustion engine leveraging late intake valve closings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kassa, Mateos; Hall, Carrie; Ickes, Andrew

    Advanced internal combustion engines, although generally more efficient than conventional combustion engines, often encounter limitations in multi-cylinder applications due to variations in the combustion process encountered across cylinders and between cycles. This study leverages experimental data from an inline 6-cylinder heavy-duty dual fuel engine equipped with exhaust gas recirculation (EGR), a variable geometry turbocharger, and a fully-flexible variable intake valve actuation system to study cylinder-to-cylinder variations in power production and the underlying uneven fuel distribution that causes these variations. The engine is operated with late intake valve closure timings in a dual-fuel combustion mode in which a high reactivity fuelmore » is directly injected into the cylinders and a low reactivity fuel is port injected into the cylinders. Both dual fuel implementation and late intake valve closing (IVC) timings have been shown to improve thermal efficiency. However, experimental data from this study reveal that when late IVC timings are used on a multi-cylinder dual fuel engine a significant variation in IMEP across cylinders results and as such, leads to efficiency losses. The difference in IMEP between the different cylinders ranges from 9% at an IVC of 570°ATDC to 38% at an IVC of 610°ATDC and indicates an increasingly uneven fuel distribution. These experimental observations along with engine simulation models developed using GT-Power have been used to better understand the distribution of the port injected fuel across cylinders under various operating conditions on such dual fuel engines. This study revealed that the fuel distribution across cylinders in this dual fuel application is significantly affected by changes in the effective compression ratio as determined by the intake valve close timing as well as the design of the intake system (specifically the length of the intake runners). Late intake valve closures allow a portion of the trapped air and port injected fuel to flow back out of the cylinders into the intake manifold. The fuel that is pushed back in the intake manifold is then unevenly redistributed across the cylinders largely due to the dominating direction of the flow in the intake manifold. The effects of IVC as well as the impact of intake runner length on fuel distribution were quantitatively analyzed and a model was developed that can be used to accurately predict the fuel distribution of the port injected fuel at different operating conditions with an average estimation error of 1.5% in cylinder-specific fuel flow.« less

  18. Lymphatic pump treatment increases thoracic duct lymph flow in conscious dogs with edema due to constriction of the inferior vena cava.

    PubMed

    Prajapati, Parna; Shah, Pankhil; King, Hollis H; Williams, Arthur G; Desai, Pratikkumar; Downey, H Fred

    2010-09-01

    Osteopathic lymphatic pump treatments (LPT) are used to treat edema, but their direct effects on lymph flow have not been studied. In the current study, we examined the effects of LPT on lymph flow in the thoracic duct of instrumented conscious dogs in the presence of edema produced by constriction of the inferior vena cava (IVC). Six dogs were surgically instrumented with an ultrasonic flow transducer on the thoracic lymph duct and catheters in the descending thoracic aorta and in IVC. After postoperative recovery, lymph flow and hemodynamic variables were measured 1) pre-LPT, 2) during 4 min LPT, 3) post-LPT, in the absence and presence of edema produced by IVC constriction. This constriction increased abdominal girth from 60 +/-2.6 to 75 +/- 2.9 cm. Before IVC constriction, LPT increased lymph flow (P < 0.05) from 1.9 +/- 0.2 ml/min to a maximum of 4.7 +/-1.2 ml/min, whereas after IVC constriction, LPT increased lymph flow (P < 0.05) from 7.9 +/-2.2 to a maximum of 11.7 +/-2.2 ml/min. The incremental lymph flow mobilized by 4 min of LPT (ie, the flow that exceeded 4 min of baseline flow), was 10.6 ml after IVC constriction. This incremental flow was not significantly greater than that measured before IVC constriction. Edema caused by IVC constriction markedly increased lymph flow in the thoracic duct. LPT increased thoracic duct lymph flow before and after IVC constriction. The lymph flow mobilized by 4 min of LPT in presence of edema was not significantly greater than that mobilized prior to edema.

  19. Pre-Clinical Model to Study Recurrent Venous Thrombosis in the Inferior Vena Cava.

    PubMed

    Andraska, Elizabeth A; Luke, Catherine E; Elfline, Megan A; Henke, Samuel P; Madapoosi, Siddharth S; Metz, Allan K; Hoinville, Megan E; Wakefield, Thomas W; Henke, Peter K; Diaz, Jose A

    2018-06-01

     Patients undergoing deep vein thrombosis (VT) have over 30% recurrence, directly increasing their risk of post-thrombotic syndrome. Current murine models of inferior vena cava (IVC) VT model host one thrombosis event.  We aimed to develop a murine model to study IVC recurrent VT in mice.  An initial VT was induced using the electrolytic IVC model (EIM) with constant blood flow. This approach takes advantage of the restored vein lumen 21 days after a single VT event in the EIM demonstrated by ultrasound. We then induced a second VT 21 days later, using either EIM or an IVC ligation model for comparison. The control groups were a sham surgery and, 21 days later, either EIM or IVC ligation. IVC wall and thrombus were harvested 2 days after the second insult and analysed for IVC and thrombus size, gene expression of fibrotic markers, histology for collagen and Western blot for citrullinated histone 3 (Cit-H3) and fibrin.  Ultrasound confirmed the first VT and its progressive resolution with an anatomical channel allowing room for the second thrombus by day 21. As compared with a primary VT, recurrent VT has heavier walls with significant up-regulation of transforming growth factor-β (TGF-β), elastin, interleukin (IL)-6, matrix metallopeptidase 9 (MMP9), MMP2 and a thrombus with high citrullinated histone-3 and fibrin content.  Experimental recurrent thrombi are structurally and compositionally different from the primary VT, with a greater pro-fibrotic remodelling vein wall profile. This work provides a VT recurrence IVC model that will help to improve the current understanding of the biological mechanisms and directed treatment of recurrent VT. Schattauer GmbH Stuttgart.

  20. A marked proportional rise in IVC aldosterone following cosyntropin administration during AVS is a signal to the presence of adrenal hyperplasia in primary aldosteronism.

    PubMed

    Kline, G A; Pasieka, J L; Harvey, A; So, B; Dias, V C

    2014-05-01

    We hypothesized aldosteronoma responsiveness to cosyntropin may be a characterizing feature that could be determined in addition to standard adrenal vein sampling (AVS) data. We reviewed an AVS database from June 2005 to October 2011 including 65 patients with confirmed primary aldosteronism (PA) who underwent AVS and, if applicable, unilateral adrenalectomy. Patients were divided into confirmed lateralized and non-lateralized groups and subgrouped by histology. Plasma aldosterone in inferior vena cava (IVC) pre- and post-cosyntropin infusion during AVS was measured. Peak aldosterone and proportional change was compared between groups. Baseline and peak IVC aldosterone was higher in lateralized patients but incremental aldosterone rise was much greater in subjects with bilateral hyperplasia. From receiver operator characteristics (ROC) analysis, the optimized diagnostic cut point of peak IVC aldosterone of >649 pmol l(-1) would have a sensitivity of 94% for surgical disease although specificity of just 59%. A 250% increase in IVC aldosterone following cosyntropin would be specific enough to exclude 87% of surgical/lateralized disease. These diagnostic capabilities are similar to other results with non-AVS tests performed for diagnosis of lateralization. Although not specific enough to replace standard AVS interpretation, a marked IVC aldosterone increase after cosyntropin during AVS is a useful additional test to diagnose non-lateralizing forms of PA. Such a calculation requires no additional expense or tests.

  1. Black pepper essential oil to enhance intravenous catheter insertion in patients with poor vein visibility: a controlled study.

    PubMed

    Kristiniak, Susan; Harpel, Jean; Breckenridge, Diane M; Buckle, Jane

    2012-11-01

    To evaluate the effect of topically applied black pepper essential oil on easing intravenous catheter insertion (IVC) in patients with no palpable or visible veins compared to a control group (standard nursing practice). Randomized, controlled study. One hundred twenty hospitalized patients, who were referred to a hospital vascular team because of difficulty in accessing veins for IVC insertion. Topical application of 20% essential oil of black pepper in aloe vera gel or standard nursing care (hot packs with or without vigorous tactile stimulation). Pre- and post-test vein visibility and/or palpability and number of attempts at IVC insertion. A higher percentage of patients achieved optimal scoring (vein score=2) or improved scoring (vein score of 1 or 2) to black pepper intervention than standard nursing care. The black pepper group also reduced the number of patients whose veins were still not visible or palpable after the intervention to nearly half that of the control group (p<0.05). The number of IVC attempts following black pepper was also half that of the control group. Topical application of black pepper is a viable and effective way to enhance vein visibility and palpability prior to intravenous insertion in patients with limited vein accessibility; it also improves ease of IVC insertion.

  2. Outcomes of Stent Placement for Chronic Occlusion of a Filter-bearing Inferior Vena Cava in Patients with Severe Post-thrombotic Syndrome.

    PubMed

    Ye, K; Lu, X; Li, W; Yin, M; Liu, X; Qin, J; Liu, G; Jiang, M

    2016-12-01

    To evaluate the technical aspects and short-term clinical results of stent placement for chronic occlusion of a filter-bearing inferior vena cava (IVC) in patients with severe post-thrombotic syndrome (PTS). A retrospective analysis of 24 patients with severe PTS associated with occlusion of a filter-bearing IVC treated by stent placement was conducted at a single institution from January 2010 to December 2014. Patient-reported quality of life and limb Villalta scores were evaluated before and after treatment by questionnaire and clinical examination, respectively. Stent patency was evaluated by duplex Doppler ultrasound, venography, or venous computed tomographic (CT) angiography. All patients tolerated the procedure well. Nineteen patients with filter-bearing IVC and bilateral iliofemoral occlusions were treated with "double-barrel" stents, two were treated with fenestrated stents, and the remaining three patients were treated by unilateral stent placement of the iliofemoral vein and filter-bearing IVC. Quality of life and Villalta scores were significantly improved (p < .001) after the procedure. The 1-year, and 2-year cumulative primary and secondary stent patency rates were 67% and 91%, and 45% and 77%, respectively. During a median follow-up period of 27 months (range 3-55 months), the cumulative rates of complete relief of pain (visual analog scale >5) and swelling (grade 3) were 77% (13 of 17 limbs at risk) and 75% (24 of 32 limbs at risk), respectively. There were 23 limbs with active ulcers and the cumulative rate of ulcer healing at 2 years was 73%. There were no cases of clinical bleeding, symptomatic pulmonary embolism, or mortality. Recanalization of an occluded IVC filter and stent placement through the filter is a feasible and safe method for management of PTS associated with filter-bearing IVC occlusions, with acceptable short-term stent patency and clinical results. However, close follow-up after procedure is necessary because of a relatively high re-occlusion rate. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  3. IVC filter retrieval in adolescents: experience in a tertiary pediatric center.

    PubMed

    Guzman, Anthony K; Zahra, Mahmoud; Trerotola, Scott O; Raffini, Leslie J; Itkin, Maxim; Keller, Marc S; Cahill, Anne Marie

    2016-04-01

    Inferior vena cava (IVC) filters are commonly implanted with the intent to prevent life-threatening pulmonary embolism in at-risk patients with contraindications to anticoagulation. Various studies have reported increases in the rate of venous thromboembolism within the pediatric population. The utility and safety of IVC filters in children has not yet been fully defined. To describe the technique and adjunctive maneuvers of IVC filter removal in children, demonstrate its technical success and identify complications. A retrospective 10-year review was performed of 20 children (13 male, 7 female), mean age: 15.1 years (range: 12-19 years), who underwent IVC filter retrieval. Eleven of 20 (55%) were placed in our institution. Electronic medical records were reviewed for filter characteristics, retrieval technique, technical success and complications. The technical success rate was 100%. Placement indications included: deep venous thrombosis with a contraindication to anticoagulation (10/20, 50%), free-floating thrombus (4/20, 20%), post-trauma pulmonary embolism prophylaxis (3/20, 15%) and pre-thrombolysis pulmonary patient (1/20, 5%). The mean implantation period was 63 days (range: 20-270 days). Standard retrieval was performed in 17/20 patients (85%). Adjunctive techniques were performed in 3/20 patients (15%) and included the double-snare technique, balloon assistance and endobronchial forceps retrieval. Median procedure time was 60 min (range: 45-240 min). Pre-retrieval cavogram demonstrated filter tilt in 5/20 patients (25%) with a mean angle of 17° (range: 8-40). Pre-retrieval CT demonstrated strut wall penetration and tip embedment in one patient each. There were two procedure-related complications: IVC mural dissection noted on venography in one patient and snare catheter fracture requiring retrieval in one patient. There were no early or late complications. In children, IVC filter retrieval can be performed safely but may be challenging, especially in cases of filter tilt or embedding. Adjunctive techniques may increase filter retrieval rates.

  4. Pilot in vivo study of an absorbable polydioxanone vena cava filter.

    PubMed

    Eggers, Mitchell D; McArthur, Mark J; Figueira, Tomas A; Abdelsalam, Mohamed E; Dixon, Katherine P; Pageon, Laura R; Wallace, Michael J; Huang, Steven Y

    2015-10-01

    The objectives of this study were to evaluate tensile strength retention of polydioxanone as a function of time in a swine venous system and to assess the feasibility of an absorbable inferior vena cava (IVC) filter made from polydioxanone in a pilot swine study. Twenty strands (60 cm each) of size 1 polydioxanone absorbable suture (Ethicon, Somerville, NJ) were placed in the central venous system of domestic swine. Strands were harvested at weekly intervals during 10 weeks for tensile strength testing. Results were compared with control samples obtained from an in vitro engineered circulation system containing sodium phosphate buffer solution. Three IVC filters braided from polydioxanone suture were also catheter deployed in three swine to assess absorbable IVC filter feasibility. Polydioxanone retained 82% tensile strength in vitro vs 79% in vivo at 35 days (P > .22), the desired prophylactic duration. For IVC filters made from polydioxanone, technical success of placement was achieved in all three filters deployed (100%). Autologous thrombus deployed inferior to the filter remained trapped in the filter until thrombus resorption, with no evidence of pulmonary emboli on follow-up computed tomography. There were no instances of caval penetration, filter-induced IVC thrombosis, filter migration, or tilt >15 degrees with imaging and clinical follow-up carried out to 32 weeks. Strength retention of polydioxanone suture placed in the venous system of swine is similar to earlier in vitro studies out to 10 weeks (P > .06 for all weeks) and is more than sufficient (8.20 ± 0.37 kg mean load at break for size 1) to trap thrombus. Pilot animal study suggests that an absorbable polydioxanone IVC filter can be catheter deployed to capture and to hold iatrogenically administered autologous thrombus through resorption. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  5. Retrospective analysis of outcomes following inferior vena cava (IVC) filter placement in a managed care population.

    PubMed

    Everhart, Damian; Vaccaro, Jamieson; Worley, Karen; Rogstad, Teresa L; Seleznick, Mitchel

    2017-08-01

    The role of inferior vena cava filter (IVC) filters for prevention of pulmonary embolism (PE) is controversial. This study evaluated outcomes of IVC filter placement in a managed care population. This retrospective cohort study evaluated data for individuals with Humana healthcare coverage 2013-2014. The study population included 435 recipients of prophylactic IVC filters, 4376 recipients of therapeutic filters, and two control groups, each matched to filter recipients. Patients were followed for up to 2 years. Post-index anticoagulant use, mortality, filter removal, device-related complications, and all-cause utilization. Adjusted regression analyses showed a positive association between filter placement and anticoagulant use at 3 months: odds ratio (ORs) 3.403 (95% CI 1.912-6.059), prophylactic; OR, 1.356 (95% CI 1.164-1.58), therapeutic. Filters were removed in 15.67% of prophylactic and 5.69% of therapeutic filter cases. Complication rates were higher with prophylactic procedures than with therapeutic procedures and typically exceeded 2% in the prophylactic group. Each form of filter placement was associated with increases in all-cause hospitalization (regression coefficient 0.295 [95% CI 0.093-0.498], prophylactic; 0.673 [95% CI 0.547-0.798], therapeutic) and readmissions (OR 2.444 [95% CI 1.298-4.602], prophylactic; 2.074 [95% CI 1.644-2.616], therapeutic). IVC filter placement in this managed care population was associated with increased use of anticoagulants and greater healthcare utilization compared to controls, low rates of retrieval, and notable rates of device-related complications, with effects especially pronounced in assessments of prophylactic filters. These findings underscore the need for appropriate use of IVC filters.

  6. Computational Simulations of Inferior Vena Cava (IVC) Filter Placement and Hemodynamics in Patient-Specific Geometries

    NASA Astrophysics Data System (ADS)

    Aycock, Kenneth; Sastry, Shankar; Kim, Jibum; Shontz, Suzanne; Campbell, Robert; Manning, Keefe; Lynch, Frank; Craven, Brent

    2013-11-01

    A computational methodology for simulating inferior vena cava (IVC) filter placement and IVC hemodynamics was developed and tested on two patient-specific IVC geometries: a left-sided IVC, and an IVC with a retroaortic left renal vein. Virtual IVC filter placement was performed with finite element analysis (FEA) using non-linear material models and contact modeling, yielding maximum vein displacements of approximately 10% of the IVC diameters. Blood flow was then simulated using computational fluid dynamics (CFD) with four cases for each patient IVC: 1) an IVC only, 2) an IVC with a placed filter, 3) an IVC with a placed filter and a model embolus, all at resting flow conditions, and 4) an IVC with a placed filter and a model embolus at exercise flow conditions. Significant hemodynamic differences were observed between the two patient IVCs, with the development of a right-sided jet (all cases) and a larger stagnation region (cases 3-4) in the left-sided IVC. These results support further investigation of the effects of IVC filter placement on a patient-specific basis.

  7. Outcomes of endovascular reconstruction of the inferior vena cava with self-expanding nitinol stents.

    PubMed

    Sebastian, Tim; Dopheide, Jörn F; Engelberger, Rolf P; Spirk, David; Kucher, Nils

    2018-05-01

    Occlusion of the inferior vena cava (IVC) often causes venous claudication, leg swelling, or skin changes. We hypothesized that the outcome of nitinol stents for endovascular reconstruction of the IVC is similar to the outcome reported for steel alloy stents. From the prospective Bern Venous Stent Registry, we investigated technical success, patency rates, and clinical outcome in consecutive patients with endovascular IVC reconstruction. During routine follow-up visits, stent patency was assessed by duplex ultrasound. Clinical outcomes were evaluated using the Bozkaya score, Villalta score, and revised Venous Clinical Severity Score. Of the 62 patients (mean age, 46 ± 18 years), 33 (53%) patients were treated for the post-thrombotic syndrome, 17 (27%) for acute thrombosis, and 12 (19%) for nonthrombotic IVC occlusion. Technical success was achieved in 61 (98%) patients, with a mean of 4.5 ± 1.9 stents (iliac kissing stents in 84%). During follow-up (mean, 21 months), 22 (36%) underwent endovascular reintervention for symptomatic stent stenosis (13 [21%] with complete stent occlusion). Primary, primary assisted, and secondary patency rates at 24 months were 57% (95% confidence interval [CI], 50%-73%), 76% (95% CI, 65%-86%), and 87% (95% CI, 80%-95%), respectively. None developed new ulcers, and all eight patients with venous ulcers at baseline had complete healing. Twenty-nine (48%) patients showed significant clinical improvement, and another 26 (43%) were free from any symptoms or signs of venous hypertension. Patients with post-thrombotic venographic changes of the femoral veins at baseline or a history of thrombosis were more likely to lose primary patency compared with patients with normal leg inflow veins and no history of thrombosis (19 [48%] vs 3 [16%]; P = .02). The clinical outcome of endovascular reconstruction of the IVC with nitinol stents was favorable. However, approximately one-third of the patients required reintervention to maintain stent patency, most likely because of the impaired venous inflow. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  8. Predicting inferior vena cava (IVC) filter retrievability using positional parameters: A comparative study of various filter types.

    PubMed

    Gotra, A; Doucet, C; Delli Fraine, P; Bessissow, A; Dey, C; Gallix, B; Boucher, L-M; Valenti, D

    2018-05-14

    To compare changes in inferior vena cava (IVC) filter positional parameters from insertion to removal and examine how they affect retrievability amongst various filter types. A total of 447 patients (260 men, 187 women) with a mean age of 55 years (range: 13-91 years) who underwent IVC filter retrieval between 2007-2014 were retrospectively included. Post-insertion and pre-retrieval angiographic studies were assessed for filter tilt, migration, strut wall penetration and retrieval outcomes. ANCOVA and multiple logistic regression models were used to analyze factors affecting retrieval success. Pairwise comparisons between filter types were performed. Of 488 IVC filter retrieval attempts, 94.1% were ultimately successful. The ALN filter had the highest mean absolute value of tilt (5.6 degrees), the Optease filter demonstrated the largest mean migration (-8.0mm) and the Bard G2 filter showed highest mean penetration (5.2mm). Dwell time of 0-90 days (OR, 11.1; P=0.01) or 90-180 days (OR, 2.6; P=0.02), net tilt of 10-15 degrees (OR 8.9; P=0.05), caudal migration of -10 to 0mm (OR, 3.46; P=0.03) and penetration less than 3mm (OR, 2.6; P=0.01) were positive predictors of successful retrievability. Higher odds of successful retrieval were obtained for the Bard G2X, Bard G2 and Cook Celect when compared to the ALN and Cordis Optease filters. Shorter dwell time, lower mean tilt, caudal migration and less caval wall penetration are positive predictors of successful IVC filter retrieval. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  9. En-bloc Transplantation: an Eligible Technique for Unilateral Dual Kidney Transplantation

    PubMed Central

    Salehipour, M.; Bahador, A.; Nikeghbalian, S.; Kazemi, K.; Shamsaeifar, A. R.; Ghaffaripour, S.; Sahmeddini, M. A.; Salahi, H.; Bahreini, A.; Janghorban, P.; Gholami, S.; Malek-Hosseini, S. A.

    2012-01-01

    Background: Kidney transplantation is the best available treatment for patients with end-stage renal disease. Objective: To evaluate the en bloc anastomosis technique for unilateral dual kidney transplantation (DKT). Methods: From May to October 2011, 5 patients (4 women and 1 man) with mean age of 31.8 years underwent unilateral DKT with this technique in which distal end of the aorta and proximal end of inferior vena cava (IVC) were closed with running sutures. Then, proximal end of the aorta and distal end of the IVC were anastomosed to internal (or external) iliac artery and external iliac vein, respectively. Results: Post-operative course was uneventful. No vascular and urologic complications developed; all patient had acceptable serum creatinine at discharge time and up of 2–6 months of post-operation follow up. Conclusion: Unilateral DKT is a safe method for performing DKT. The proposed en bloc anastomosis can improve the outcome of the graft by reducing the cold ischemia and the operation time. PMID:25013633

  10. En-bloc Transplantation: an Eligible Technique for Unilateral Dual Kidney Transplantation.

    PubMed

    Salehipour, M; Bahador, A; Nikeghbalian, S; Kazemi, K; Shamsaeifar, A R; Ghaffaripour, S; Sahmeddini, M A; Salahi, H; Bahreini, A; Janghorban, P; Gholami, S; Malek-Hosseini, S A

    2012-01-01

    Kidney transplantation is the best available treatment for patients with end-stage renal disease. To evaluate the en bloc anastomosis technique for unilateral dual kidney transplantation (DKT). From May to October 2011, 5 patients (4 women and 1 man) with mean age of 31.8 years underwent unilateral DKT with this technique in which distal end of the aorta and proximal end of inferior vena cava (IVC) were closed with running sutures. Then, proximal end of the aorta and distal end of the IVC were anastomosed to internal (or external) iliac artery and external iliac vein, respectively. Post-operative course was uneventful. No vascular and urologic complications developed; all patient had acceptable serum creatinine at discharge time and up of 2-6 months of post-operation follow up. Unilateral DKT is a safe method for performing DKT. The proposed en bloc anastomosis can improve the outcome of the graft by reducing the cold ischemia and the operation time.

  11. Percutaneous closure of a hemodynamically significant connection between the inferior vena cava and the left atrium.

    PubMed

    Wiebe, Jens; Rixe, Johannes; Nef, Holger

    2015-10-01

    A connection between the inferior vena cava (IVC) and the left atrium (LA) can occur as a rare complication after surgical atrial septum defect (ASD) repair. We demonstrate the first case of a percutaneous closure of this connection. A 67-year-old female was admitted to hospital due to exertional dyspnea. A history of a surgical ASD repair in 1960 and 1966 with a residual shunt was already known. Transesophageal echocardiography and a CT scan revealed a hemodynamically significant drainage of the IVC into the LA. This connection was successfully closed percutaneously with an AMPLATEZR Duct Occluder I (St. Jude Medical, St. Paul, MN). Post-procedural CT-scan and transthoracic echocardiography demonstrated a stable position and there was also no evidence of a residual shunt. The patient reported a significant reduction of exertional dyspnea. Percutaneous closure of an IVC to LA connection in this case was safe and feasible. The decision about which device is optimal must be made on an individual basis. © 2015 Wiley Periodicals, Inc.

  12. Patients with inferior vena cava thrombosis frequently present with lower back pain and bilateral lower-extremity deep vein thrombosis.

    PubMed

    Kraft, Christiane; Hecking, Carola; Schwonberg, Jan; Schindewolf, Marc; Lindhoff-Last, Edelgard; Linnemann, Birgit

    2013-07-01

    Inferior vena cava (IVC) thrombosis is rare, and data about the clinical presentation of patients are scarce. Therefore, we reviewed all cases of IVC thrombosis consecutively registered in the MAISTHRO (MAin-ISar-THROmbosis) database and described patients’ characteristics in terms of their clinical presentations in the acute setting of IVC thrombosis. From the MAISTHRO registry, which enrolled 1470 consecutive patients with documented histories of venous thromboembolism, we identified 60 patients (0,4 %; females 60 %) with IVC thrombosis and 888 patients (60.4 %; females 55 %) with isolated lower-extremity deep vein thrombosis (LE-DVT). The median age at the time of IVC thrombosis manifestation was 36.5 years (9 to 83). IVC thrombosis was the initial VTE event in 47 patients (78 %). In the majority of cases, IVC thrombosis extended to the lower-extremity veins, and both lower extremities were affected in 17 cases (28 %). The initial clinical symptom of IVC thrombosis was lower back or abdominal pain which preceded typical symptoms of LE-DVT in 29 (48 %) patients. Symptomatic pulmonary embolism was more frequently observed in IVC thrombosis patients when compared to a sex- and age-matched subgroup of LE-DVT patients, although the difference was not significant (27 % vs. 12 %; p = 0.064). Malignant disease was the only established VTE risk factor with a higher prevalence among IVC thrombosis patients than patients with isolated LE-DVT (27 % vs. 9 %; p = 0.015). Congenital IVC anomalies were identified in another eight IVC thrombosis patients (13 %). IVC thrombosis should be considered a differential diagnosis for inexplicable lower back or abdominal pain especially in young patients. Malignant disease and congenital IVC anomalies seem to be predisposing factors for thrombosis involving the inferior vena cava.

  13. Infra-renal angles, entry into inferior vena cava and vertebral levels of renal veins.

    PubMed

    Satyapal, K S

    1999-10-01

    Current norms for renal vasculature hold true in only half the population. Standard textbooks perpetuate old misconceptions regarding renal venous anatomy. This study is aimed to determine left and right infra-renal angles (L-IRA, R-IRA); entry level of renal veins into the inferior vena cava (IVC), and height of IVC under renal vein influence; and their vertebral level. One hundred morphologically normal en-bloc renal specimens randomly selected from post-mortem examinations were dissected and resin casted. IRA were also measured from venograms of 32 adult and 11 foetal cadavers, as were vertebral entry levels. IRA measurements (degrees) were as follows: left, 55 degrees +/- 16 degrees (20 degrees -102 degrees ); right, 60 degrees +/- 17 degrees (10 degrees -93 degrees ). Left vein entered IVC higher than right 54%, lower 36%, and opposite each other 10%. Vertical distance between lower borders of veins was 1.0 +/- 0.9 cm. Vertical distance of IVC under renal vein influence was 2.3 +/- 1.0 cm. Vertebral level of veins in adults lies between TI2-L2. In foetuses, IRA was as follows: left, 65 degrees +/- 12 degrees (45 degrees -90 degrees ); right, 58 degrees +/- 7 degrees (40 degrees -70 degrees ); vertebral level between T12 and L3. Similar IRA values from literature noted on right, 51 degrees (26 degrees -100 degrees ); differences on left, 77 degrees (43 degrees -94 degrees ), clearly differing from Williams et al. (Gray's Anatomy, 37(th) ed, 1989) statement that renal veins "open into the inferior vena cava almost at right angles." Large variations of IRA are not surprising since kidneys are considered normally "floating viscera," varying position with posture and respiratory movement as well as in live vs. cadaveric subjects. The entry level into the IVC also differs from Williams et al. This study uniquely quantitated actual height difference between lower borders of left and right veins. The data presented appears to be the first documentation of vertebral level of entry of renal veins into IVC in foetuses. These findings are clinically important for the angiographer, catheter design, and planning porto-renal shunt procedures. Copyright 1999 Wiley-Liss, Inc.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petitpas, Guillaume; Whitesides, Russel

    UQHCCI_2 propagates the uncertainties of mass-average quantities (temperature, heat capacity ratio) and the output performances (IMEP, heat release, CA50 and RI) of a HCCI engine test bench using the pressure trace, and intake and exhaust molar fraction and IVC temperature distributions, as inputs (those inputs may be computed using another code UQHCCI_2, or entered independently).

  15. CT Appearance of Traumatic Inferior Vena Cava Injury.

    PubMed

    Tsai, Richard; Raptis, Constantine; Schuerer, Douglas J; Mellnick, Vincent M

    2016-07-19

    CT plays a crucial role in the evaluation of stable patients with blunt and penetrating trauma in the emergency department. Among the more severe injuries that may occur in penetrating and blunt trauma are those to the inferior vena cava (IVC). The purpose of this study was to evaluate and differentiate the CT findings associated with penetrating versus blunt trauma to the IVC to aid the radiologist in diagnosing IVC injuries. Cases of blunt and penetrating IVC injury were retrospectively identified using search queries. Criteria for inclusion were preoperative contrast-enhanced CT and surgically confirmed caval injury or direct findings of caval injury on CT with patient death before surgical confirmation could be obtained. Twelve cases of traumatic IVC injury were identified over a 9-year period: six blunt and six penetrating. The most common finding was a retroperitoneal hematoma, seen in 75% of cases. Eighty-three percent of blunt injuries were associated with hepatic lacerations and contrast material extravasation. Thirty-three percent of penetrating IVC injuries were associated with extravasation. Contour abnormalities were seen in 50% of blunt and 17% of penetrating injuries to the IVC. All three cases of IVC injury resulting in mortality occurred in the retrohepatic segment. Injury to the IVC is frequently fatal in patients with penetrating or blunt trauma. The CT appearance of IVC injury is dichotomous between the two causes, with blunt IVC injury more likely to show extravasation, contour abnormality, and associated hepatic laceration. Injury of the retrohepatic IVC portends a poor outcome. With the continued use of CT for evaluation of trauma patients, the radiologist should be familiar with IVC injury and its different CT appearances.

  16. Retrievable Inferior vena cava filters in pregnancy: Risk versus benefit?

    PubMed

    Crosby, David A; Ryan, Kevin; McEniff, Niall; Dicker, Patrick; Regan, Carmen; Lynch, Caoimhe; Byrne, Bridgette

    2018-03-01

    Venous thromboembolism remains one of the leading causes of maternal mortality in the developed world. Retrievable inferior vena cava (IVC) filters have a role in the prevention of lethal pulmonary emboli when anticoagulation is contraindicated or has failed [1]. It is unclear whether or not the physiological changes in pregnancy influence efficacy and complications of these devices. The decision to place an IVC filter in pregnancy is complex and there is limited information in terms of benefit and risk to the mother. The objective of this study was to determine the efficacy and safety of these devices in pregnancy and to compare these with rates reported in the general population. The aim of this study was report three recent cases of retrievable IVC filter use in pregnant women in our department and to perform a systematic review of the literature to identify published cases of filters in pregnancy. The efficacy and complication rates of these devices in pregnancy were estimated and compared to rates reported in the general population in a recent review [2]. Fisher's exact test was used for statistical analysis. In addition to our three cases, 16 publications were identified with retrievable IVC filter use in 40 pregnant women resulting in a total of 43 cases. There was no pulmonary embolus in the pregnant group (0/43) compared to 57/6291 (0.9%) in the general population. Thrombosis of the filter (2.3% vs. 0.9%, p = 0.33) and perforation of the IVC (7.0% vs 4.4%, p = 0.44) were more common in pregnancy compared to the general population but the difference was not statistically significant. Failure to retrieve the filter is more likely to occur in pregnancy (26% vs. 11%, p = 0.006) but this did not correlate with the type of device (p = 0.61), duration of insertion (p = 0.58) or mode of delivery (p = 0.37). Data for retrievable IVC filters in pregnancy is limited and there may be a publication bias towards complicated cases. This study shows that the filter appears to protect against PE in pregnancy but the numbers are small. Complications such as filter thrombosis and IVC penetration appear to be higher in pregnancy but this difference is not statistically significant. It is not possible to retrieve the device in one out of every four pregnant women. This has implications in terms of long term risk of lower limb thrombosis and post thrombotic syndrome. The decision to use an IVC filter in pregnancy needs careful consideration by a multidisciplinary team. The benefit and risk assessment should be individualised and clearly outlined to the patient. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Impact of Physician Education and a Dedicated Inferior Vena Cava Filter Tracking System on Inferior Vena Cava Filter Use and Retrieval Rates Across a Large US Health Care Region.

    PubMed

    Wang, Stephen L; Cha, Hsien-Hwa A; Lin, James R; Francis, Bolanos; Elizabeth, Wakley; Martin, Porras; Rajan, Sudhir

    2016-05-01

    To evaluate the effects of physician familiarity with current evidence and guidelines on inferior vena cava (IVC) filter use and the availability of IVC filter tracking infrastructure on retrieval rates. Fourteen continuing medical education-approved in-hospital grand rounds covering evidence-based review of the literature on IVC filter efficacy, patient-centered outcomes, guidelines for IVC filter indications, and complications were performed across a large United States (US) health care region serving more than 3.5 million members. A computer-based IVC filter tracking system was deployed simultaneously. IVC filter use, rates of attempted retrieval, and fulfillment of guidelines for IVC filter indications were retrospectively evaluated at each facility for 12 months before intervention (n = 427) and for 12 months after intervention (n = 347). After education, IVC filter use decreased 18.7%, with a member enrollment-adjusted decrease of 22.2%, despite an increasing IVC filter use trend for 4 years. Reduction in IVC filter use at each facility strongly correlated with physician attendance at grand rounds (r = -0.69; P = .007). Rates of attempted retrieval increased from 38.9% to 54.0% (P = .0006), with similar rates of successful retrieval (82.3% before education and 85.8% after education on first attempt). Improvement in IVC filter retrieval attempts correlated with physician attendance at grand rounds (r = 0.51; P = .051). IVC filter dwell times at first retrieval attempt were similar (10.2 wk before and 10.8 wk after). Physician education dramatically reduced IVC filter use across a large US health care region, and represents a learning opportunity for physicians who request and place them. Education and a novel tracking system improved rates of retrieval for IVC filter devices. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  18. Atrophic inferior vena cava is a marker of chronicity of intra-filter and inferior vena cava thrombosis: based on CT findings.

    PubMed

    Chen, Liang; Shi, Wanyin; Gu, Jianping; He, Xu; Lou, Wensheng

    2018-04-11

    A permanently indwelling filter in the inferior vena cava (IVC) may induce caval thrombosis, which could develop and evolve from an acute to a chronic phase. The differential diagnosis of acute and chronic thromboses determines the treatment strategy. The role of computed tomography (CT) in diagnosing acute and chronic intra-filter and IVC thromboses has not been well established. This retrospective study summarizes the CT signs that indicate acute and chronic phases of intra-filter and IVC thromboses. This study included eight patients who developed a lower-extremity deep venous thrombosis (DVT) and were treated with intracaval filter placement as an alternative to anticoagulation and thrombolysis. During the follow-up, all patients developed an intra-filter thrombosis in the IVC confirmed by CT and/or CT venography (CTV). Demographic and CT data of all patients during the follow-up period were collected for analysis. All patients had normal-appearing IVCs prior to filter placement, as shown on trans-femoral venography. Eight filters (five TrapEase, three OptEase) were placed in the eight IVCs, respectively. Subsequently, IVC-CT or CTV revealed acute intra-filter or IVC thrombosis in all eight patients, manifesting as an intracaval filling defect and thickened IVC wall. Filter protrusion and secondary caval atrophy seen on CT indicated a chronically occluded IVC. IVC thrombosis may result from filter placement. The chronicity of caval thrombotic occlusion is likely to be associated with filter protrusion and secondary IVC atrophy revealed on CT scans.

  19. Indications, retrieval rate, and complications of inferior vena cava filters: Single-center experience in Saudi Arabia.

    PubMed

    Shabib, Abdullah Bin; Alsayed, Fahad; Aldughaythir, Saad; Habeeb, Hanan; Al Tamimi, Sumayyah; Masuadi, Emad; Alzahrani, Mohsen; Alaklabi, Ali; Alotaibi, Azzam; Rajendram, Rajkumar; Almegren, Mosaad

    2018-01-01

    Inferior vena cava (IVC) filter is indicated in patients with acute venous thromboembolism (VTE) in whom therapeutic anticoagulation is contraindicated. While prophylactic insertion of an IVC filter may be considered for patients at high risk of VTE, there are significant differences between clinical guidelines on the role of IVC filters. These discrepancies have arisen predominantly because of the paucity of data on the efficacy and safety of IVC filters. We, therefore, evaluated the indications for filter insertion, the rate of filter retrieval and complications in patients who received IVC filters at King Abdulaziz Medical City (KAMC), Riyadh, Saudi Arabia. A descriptive, retrospective review of electronic- and paper-based medical records was performed. Consecutive sampling was used to study all adult patients who received an IVC filter at KAMC between 2007 and 2016 and met the inclusion criteria. A total of 382 IVC filters were inserted. 113 patients (30%) had an acute VTE and a contraindication to anticoagulation while 53 patients (14%) received an IVC filter in the absence of VTE (i.e., prophylactic). Only 124 (32.5%) IVC filters were eventually retrieved. The most common reason for nonretrieval was the need for permanent filtration (155, 60%). Thrombotic complications developed in 72 (19%) patients; nine patients had fatal pulmonary embolism. The insertion of IVC filters in this cohort was associated with low retrieval rate and relatively high incidence of thrombotic complications. Follow-up of patients is required to detect IVC filter-related complications and to increase retrieval rate.

  20. Mid- and long-term outcome of patients with permanent inferior vena cava filters: a single center review.

    PubMed

    Chow, Felix Che-Lok; Chan, Yiu-Che; Cheung, Grace Chung-Yan; Cheng, Stephen Wing-Keung

    2015-07-01

    Inferior vena cava (IVC) filters are used to prevent pulmonary embolism (PE), especially in patients with active contraindication to systemic anticoagulation. The aim of this study is to examine the outcomes of patients who received permanent IVC filters at our institution. This is a single-center retrospective observational study with review of a prospectively collected database for patients who had permanent IVC filters. Patient demographics, indications of filter placement, postprocedure clinical outcome and complications, as well as use of anticoagulant therapy were documented. Chi-squared test was used to test for statistically significant differences (IBM SPSS version 21; IBM Corp., Armonk, NY), while survival was calculated using Kaplan-Meier survival curves analysis. Between February 1998 and December 2013, a total of 109 patients with a median age of 65 (47 men, range 19-97) years had IVC filters inserted at our institution. All of them had documented venous thromboembolism (VTE) before filter placement: 99 (90.8%) had lower extremity deep vein thrombosis (DVT) (including 34 iliac, 65 infrainguinal), 9 (8.3%) had massive PE without evidence of lower limb DVT, and 1 (0.9%) had isolated IVC thrombosis. Forty-seven (43.1%) patients had PE before filter insertion. There were 2 serious procedure-related complications: one access site thrombosis and one right ventricular perforation. With a mean follow-up of 36 ± 33 months, no patient had further symptomatic PE or paradoxical embolism. There were a total of 54 (49.5%) deaths, with a 30-day mortality of 8.3%; none of them was device or procedure related. Among the 92 patients followed up, 27 (29.3%) had further VTE-either DVT in the index or the contralateral lower limb (20 patients, 21.7%), or thrombus inside the filter or the IVC (14 patients, 15.2%). Forty-one (44.6%) patients reported post-thrombotic syndrome (PTS) symptoms. Anticoagulant therapy was given to 39 (42.4%) and 55 (59.8%) patients in the periprocedural period and at any time during the study period, respectively. It did not reduce the rate of postfilter VTE or PTS in both instances. None of the filters in this series was retrieved. This observational study showed that IVC filters were effective in the prevention of PE, although symptomatic postfilter VTE and PTS were common, leading to significant morbidity. Patients who received permanent filters have high mortality on follow-up; however, none were procedure or device related. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Indications, applications, and outcomes of inferior vena cava filters for venous thromboembolism in Japanese patients.

    PubMed

    Yamashita, Yugo; Unoki, Takashi; Takagi, Daisuke; Hamatani, Yasuhiro; Ishii, Mitsuru; Iguchi, Moritake; Ogawa, Hisashi; Masunaga, Nobutoyo; Wada, Hiromichi; Hasegawa, Koji; Abe, Mitsuru; Akao, Masaharu

    2016-07-01

    A recent multicenter registry study of venous thromboembolism (VTE) patients in Japan demonstrated a high prevalence of inferior vena cava (IVC) filter placement. However, data regarding indications, applications, and outcomes of IVC filters in Japanese patients are quite limited. This study was an observational, single-center, retrospective cohort study of all consecutive patients with acute VTE treated between March 2006 and February 2014. Data extracted included patient demographics, indications, applications, and complications of IVC filters, as well as VTE recurrence and death. A total of 257 consecutive patients were analyzed. Seventy-eight patients (30 %) received IVC filters. The proportions of IVC filter placement were 26 % for deep-vein thrombosis (DVT) alone, 10 % for pulmonary embolism (PE) alone, and 46 % for both DVT and PE. There was no significant difference in patient demographics between the IVC filter group and no-IVC filter group. Stated indications for filter placement were 24 cases (30 %) of DVT in intrapelvic veins, 16 cases (20 %) of DVT in proximal veins, and 11 cases (14 %) of contraindication to anticoagulant therapy. In the IVC filter group, cases of class I indication (guidelines: JCS 75:1258-1281, 2009) numbered only 6 (8 %). Many of the retrievable IVC filters were not removed and placed permanently and the retrieval rate was 42 %. We found complications of IVC filters in 8 cases (10 %). IVC filter placement was significantly associated with a better survival rate and a higher incidence of DVT recurrence during a mean observation period of 541 days. Our research suggests the frequent use of IVC filters for VTE treatment, combined with a low retrieval rate. Most of the stated indications of IVC filter placement for VTE in Japanese patients were cases of DVT in intrapelvic veins or proximal veins, not cases of contraindication to anticoagulant therapy.

  2. Renal cell carcinoma with venous extension: prediction of inferior vena cava wall invasion by MRI.

    PubMed

    Adams, Lisa C; Ralla, Bernhard; Bender, Yi-Na Y; Bressem, Keno; Hamm, Bernd; Busch, Jonas; Fuller, Florian; Makowski, Marcus R

    2018-05-03

    Renal cell carcinoma (RCC) are accompanied by inferior vena cava (IVC) thrombus in up to 10% of the cases, with surgical resection remaining the only curative option. In case of IVC wall invasion, the operative procedure is more challenging and may even require IVC resection. This study aims to determine the diagnostic performance of contrast-enhanced magnetic resonance imaging (MRI) for the assessment of wall invasion by IVC thrombus in patients with RCC, validated with intraoperative findings. Data were collected on 81 patients with RCC and IVC thrombus, who received a radical nephrectomy and vena cava thrombectomy between February 2008 and November 2017. Forty eight patients met the inclusion criteria. Sensitivity and specificity as well as the positive and negative predictive values were calculated for preoperative MRI, based on the assessments of the two readers for visual wall invasion. Furthermore, a logistic regression model was used to determine if there was an association between intraoperative wall adherence and IVC diameter. Complete occlusion of the IVC lumen or vessel breach could reliably assess IVC wall invasion with a sensitivity of 92.3% (95%-CI: 0.75-0.99) and a specificity of 86.4% (95%-CI: 0.65-0.97) (Fisher-test: p-value< 0.001). The positive predictive value (PPV) was 88.9% (95%-CI: 0.71-0.98) and the negative predictive value reached 90.5% (95%-CI: 0.70-0.99). There was an excellent interobserver agreement for determining IVC wall invasion with a kappa coefficient of 0.90 (95%CI: 0.79-1.00). The present study indicates that standard preoperative MR imaging can be used to reliably assess IVC wall invasion, evaluating morphologic features such as the complete occlusion of the IVC lumen or vessel breach. Increases in IVC diameter are associated with a higher probability of IVC wall invasion.

  3. Techniques of adrenal venous sampling in patients with inferior vena cava or renal vein anomalies.

    PubMed

    Endo, Kenji; Morita, Satoru; Suzaki, Shingo; Yamazaki, Hiroshi; Nishina, Yu; Sakai, Shuji

    2018-06-01

    To review the techniques and technical success rate of adrenal venous sampling (AVS) in patients with inferior vena cava (IVC) or renal vein anomalies. The techniques and success rate of AVS in 15 patients with anomalies [8 with double IVC (dIVC), 3 with left IVC (ltIVC), 2 with retroaortic left renal vein (LRV), and 2 with circumaortic LRV] underwent AVS was retrospectively reviewed. Among 11 patients with IVC anomalies, the success rates for sampling the right and left adrenal veins (RAV and LAV) were 81.8 and 90.9%, respectively. In dIVC, the LAV was selected using the following four methods: approaching through the right IVC from the right femoral vein, flipping the LAV catheter tip in the LRV (n = 4) or the interiliac-communicating vein (n = 1), or through the ltIVC from the right (n = 1) or left (n = 2) femoral vein. Among the four patients with LRV anomalies, the success rate was 100% for each adrenal vein. AVS can be successfully performed in patients with anomalies. The key to technical success is understanding the venous anatomy based on pre-procedural CT images and choosing appropriate methods.

  4. Inferior vena cava collapsibility detects fluid responsiveness among spontaneously breathing critically-ill patients.

    PubMed

    Corl, Keith A; George, Naomi R; Romanoff, Justin; Levinson, Andrew T; Chheng, Darin B; Merchant, Roland C; Levy, Mitchell M; Napoli, Anthony M

    2017-10-01

    Measurement of inferior vena cava collapsibility (cIVC) by point-of-care ultrasound (POCUS) has been proposed as a viable, non-invasive means of assessing fluid responsiveness. We aimed to determine the ability of cIVC to identify patients who will respond to additional intravenous fluid (IVF) administration among spontaneously breathing critically-ill patients. Prospective observational trial of spontaneously breathing critically-ill patients. cIVC was obtained 3cm caudal from the right atrium and IVC junction using POCUS. Fluid responsiveness was defined as a≥10% increase in cardiac index following a 500ml IVF bolus; measured using bioreactance (NICOM™, Cheetah Medical). cIVC was compared with fluid responsiveness and a cIVC optimal value was identified. Of the 124 participants, 49% were fluid responders. cIVC was able to detect fluid responsiveness: AUC=0.84 [0.76, 0.91]. The optimum cutoff point for cIVC was identified as 25% (LR+ 4.56 [2.72, 7.66], LR- 0.16 [0.08, 0.31]). A cIVC of 25% produced a lower misclassification rate (16.1%) for determining fluid responsiveness than the previous suggested cutoff values of 40% (34.7%). IVC collapsibility, as measured by POCUS, performs well in distinguishing fluid responders from non-responders, and may be used to guide IVF resuscitation among spontaneously breathing critically-ill patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Inferior Vena Cava Filter Placement and Retrieval Rates among Radiologists and Nonradiologists.

    PubMed

    Guez, David; Hansberry, David R; Eschelman, David J; Gonsalves, Carin F; Parker, Laurence; Rao, Vijay M; Levin, David C

    2018-04-01

    To evaluate inferior vena cava (IVC) filter placement and retrieval rates among radiologists, vascular surgeons, cardiologists, other surgeons, and all other health care providers for Medicare fee-for-service beneficiaries in the years 2012-2015. The nationwide Medicare Physician/Supplier Procedure Summary Master Files were used to determine the volume and utilization rate of IVC filter placement, IVC filter repositioning, and IVC filter retrieval, which correspond to procedure codes 37191, 37192, and 37193, respectively. Procedural code 37193 was not available before 2012, so data were reviewed for the years 2012-2015. The total volume of Medicare IVC filter placement decreased from 57,785 in 2012 to 44,378 in 2015, with radiologists responsible for 60% of all filter placements. Volume of IVC filter placement declined across all specialties, including radiologists, who placed 33,744 in 2012 and 27,957 in 2015. In contrast, total retrieval of IVC filters increased from 4,060 removals in 2012 to 6,166 in 2015. Retrieval rate per 100,000 Medicare beneficiaries increased from 11 in 2012 to 16 in 2015. Radiologists removed the bulk of the filters: 64% in both 2012 and 2015. Vascular surgeons, cardiologists, and other surgeons retrieved, respectively, 20%, 10%, and 5% of all IVC filters in 2012 and 22%, 9%, and 5% in 2015. From 2012 to 2015, IVC filter placement steadily decreased across all specialties. Retrieval rate of IVC filters continued to rise over the same period. Radiologists were responsible for the majority of IVC filter placements and retrievals. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  6. Efficacy and Safety of Endovascular Intervention for the Management of Primary Entire-Inferior Vena Cava Occlusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Qingqiao, E-mail: 1427286069@qq.com; Huang, Qianxin, E-mail: 18705206105@163.com; Shen, Bin, E-mail: 753021357@qq.com

    PurposeThis study was designed to investigate the safety and efficacy of endovascular intervention for the treatment of primary entire-inferior vena cava (IVC) occlusion.MethodsEndovascular interventions were performed in six patients for the treatment of primary entire-IVC occlusion. IVC and hepatic venography were performed via the jugular and femoral veins. Balloon angioplasty was used to revascularize the hepatic vein and IVC and a stent was placed in the IVC to maintain patency. Postoperative color Doppler ultrasonography was performed at 1, 3, 6, and 12 months, and then annually, to monitor the patency of the hepatic vein and IVC.ResultsThe IVC and one or twomore » hepatic veins were successfully revascularized in five patients. Revascularization was successful in the right and left hepatic veins in one patient; however, IVC patency could not be established in this patient. Eleven Z-type, self-expanding stents were placed into the IVCs of five patients (three stents in two patients, two stents in two patients, and one stent in one patient). There were no instances of postoperative bleeding or mortality. Follow-up was conducted for 18–90 months (42.8 ± 26.5 months). None of the five patients suffered restenosis of the IVC or hepatic veins. However, there was one of the six cases of right hepatic vein restenosis at 18 months postprocedure that was revascularized after a second balloon dilatation.ConclusionsEndovascular intervention is safe and efficacious for the treatment of primary entire-IVC occlusion.« less

  7. Etiology and VTE risk factor distribution in patients with inferior vena cava thrombosis.

    PubMed

    Linnemann, Birgit; Schmidt, Henriette; Schindewolf, Marc; Erbe, Matthias; Zgouras, Dimitrios; Grossmann, Ralf; Schambeck, Christian; Lindhoff-Last, Edelgard

    2008-01-01

    Inferior vena cava (IVC) thrombosis is a rare event and data detailing the underlying etiology are scarce. Therefore, we reviewed all available cases of IVC thrombosis consecutively registered in the MAISTHRO (MAin-ISar-THROmbosis) database and described the prevalence of VTE risk factors and other conditions contributing to IVC thrombosis development. 53 patients (35 F, 18 M) with IVC thrombosis aged 12 to 79 years were identified. 40 patients (75.5%) developed thrombosis under the age of 45. Local problems, such as IVC anomalies or external venous compression, contributed to the development of thrombosis in 12 cases (22.6%). Lupus anticoagulants (10.9 vs. 2.3%, p=0.013) and malignoma (17.0 vs. 6.4%, p=0.023) were more prevalent in IVC thrombosis patients compared to 265 age and sex matched controls with isolated lower extremity DVT. No difference was identified with regard to inherited thrombophilia or other known VTE risk factors. Symptomatic pulmonary embolism (PE) occurred in 32.1% of IVC thrombosis patients compared to 15.2% of controls (p=0.005). Local problems such as IVC anomalies and external venous compression, malignancy and the presence of lupus anticoagulants contribute to the risk of IVC thrombosis. The risk of symptomatic pulmonary embolism in the acute setting is high.

  8. British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uberoi, Raman, E-mail: raman.Uberoi@orh.nhs.uk; Tapping, Charles Ross; Chalmers, Nicholas

    Purpose: The British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry was produced to provide an audit of current United Kingdom (UK) practice regarding placement and retrieval of IVC filters to address concerns regarding their safety. Methods: The IVC filter registry is a web-based registry, launched by the BSIR on behalf of its membership in October 2007. This report is based on prospectively collected data from October 2007 to March 2011. This report contains analysis of data on 1,434 IVC filter placements and 400 attempted retrievals performed at 68 UK centers. Data collected included patient demographics, insertionmore » and retrieval data, and patient follow-up. Results: IVC filter use in the majority of patients in the UK follows accepted CIRSE guidelines. Filter placement is usually a low-risk procedure, with a low major complication rate (<0.5 %). Cook Gunther Tulip (560 filters: 39 %) and Celect (359 filters: 25 %) filters constituted the majority of IVC filters inserted, with Bard G2, Recovery filters, Cordis Trapease, and OptEase constituting most of the remainder (445 filters: 31 %). More than 96 % of IVC filters deployed as intended. Operator inexperience (<25 procedure) was significantly associated with complications (p < 0.001). Of the IVC filters initially intended for temporary placement, retrieval was attempted in 78 %. Of these retrieval was technically successful in 83 %. Successful retrieval was significantly reduced for implants left in situ for >9 weeks versus those with a shorter dwell time. New lower limb deep vein thrombosis (DVT) and/or IVC thrombosis was reported in 88 patients following filter placement, there was no significant difference of incidence between filter types. Conclusions: This registry report provides interventional radiologists and clinicians with an improved understanding of the technical aspects of IVC filter placement to help improve practice, and the potential consequences of IVC filter placement so that we are better able to advise patients. There is a significant learning curve associated with IVC filter insertion, and when a filter is placed with the intention of removal, procedures should be in place to avoid the patient being lost to follow-up.« less

  9. Management of Noncompressible Hemorrhage Using Vena Cava Ultrasound

    DTIC Science & Technology

    2016-10-01

    with this study, Dr. Doucet has produced “Protocol Video USA-IVC Study (Version 5)” that is posted on youtube : https://youtu.be/54-Z6fiJpPY This video... youtube : https://youtu.be/54-Z6fiJpPY This video contains study design, procedures, inclusion/exclusion criteria and a demonstration to train clinical

  10. Long-Term Safety and Effectiveness of the 'OptEase' Vena Cava Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalva, Sanjeeva P., E-mail: skalva@partners.org; Marentis, Theodore C.; Yeddula, Kalpana

    Purpose: To assess the long-term safety and effectiveness of the OptEase inferior vena cava (IVC) filter. Materials and Methods: In this Institutional Review Board-approved, retrospective study, we reviewed data of 71 patients who received an OptEase filter at our institution from 2002 to 2007. Thirty-nine (55%) patients had symptoms of venous thromboembolism before filter placement. The indications for filter included contraindication to anticoagulation in 31 (44%) patients, prophylaxis against pulmonary embolism (PE) in 29 (41%) patients, and failure of anticoagulation in 11 (15%) patients. Procedure-related complications, such as symptomatic post-filter PE, deep venous thrombosis (DVT), IVC occlusion, and incidental imaging-evidentmore » filter-related complications, were recorded. Safety was assessed by the occurrence of filter-related complications during placement and follow-up. Effectiveness was assessed by the occurrence of post-filter PE. Results: Sixty-five (92%) filters were placed under fluoroscopy, and 6 (8%) were placed using intravascular ultrasound guidance. Seventy (99%) filters were placed successfully. Seven (10%) filters were placed in the suprarenal cava. Retrieval was attempted in 14 (20%) patients, and 12 filters were successfully retrieved. Clinical follow-up was available for 20 {+-} 21 months. Symptoms of postfilter PE and DVT occurred in 15% (n = 11) and 10% (n = 7) patients, respectively. None of these patients had computed tomography (CT)-proven PE, and only one had ultrasound-proven new DVT. One patient had symptomatic IVC occlusion. Follow-up abdominal CT in 20 patients showed thrombus in the filter in two of them. There were no instances of filter migration, filter tilt, or caval wall penetration. Conclusion: The OptEase filter appears to have an acceptable long-term safety profile. The filter was effective against PE.« less

  11. Comparison of right atrial pressure and central venous pressures measured at various anatomical locations in children.

    PubMed

    Lin, Ming-Chih; Fu, Yun-Ching; Jan, Sheng-Ling; Chen, Ying-Tsung; Chi, Ching-Shiang

    2005-01-01

    To compare the right atrial pressure to the central venous pressures measured at different points in spontaneously breathing children and try to find a formula to estimate right atrial pressure by central venous pressure measurement. Fifty-one children, aged 5 +/- 4.7 years, who underwent right heart catheterization were studied. All patients were sedated and breathed naturally. The mean pressure was the electronic mean of nine heart beats calculated by Philips BC4000 digital angiographic system. Mean pressure of the right atrium was compared to those measured at the high superior vena cava (SVC), low SVC, high inferior vena cava (IVC) (T10-11), middle IVC (L1-2), low IVC (L3-4), and iliac vein (L5-S1). Mean pressures of central veins were significantly higher than that of the right atrium (all p<0.01). Adjusted central venous pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) had a good agreement with the right atrial pressure. Central venous pressures are significantly higher than the right atrial pressure in spontaneously breathing children. Adjusted pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) can accurately reflect the right atrial pressure.

  12. Two cases of the double inferior venae cavae.

    PubMed

    Yano, R; Hayakawa, D; Emura, S; Chen, H; Ozawa, Y; Taguchi, H; Shoumura, S

    2000-10-01

    Two cases of the double inferior venae cavae (IVC) were found during the student dissection practice in 1997 in Gifu University School of Medicine. On the first case (70-year-old male), the calibers of the right and left IVC were 15 mm and 13 mm, respectively. An anastomosis (4-mm caliber) ran obliquely from the left internal iliac vein to the right IVC. On the second case (86-year-old male), the calibers of the right and left IVC were 15 mm and 10 mm, respectively. We found no anastomosis between the right and left IVC. Each IVC was observed behind the ureter. Both cases belong to Type BC of the classification of McClure and Butler (1925), that is based on the combinations of the right and left IVC, and on their location to the ureters. Both cases also belong to Type II-b-2 of the classification of Takemoto et al. (1978), that is based on the calibers of the right and left IVC and on the running course of the interiliac vein. These are the first and second cases among 808 cadavers in Gifu University School of Medicine and the 93rd and 94th cases in Japan since 1901.

  13. Surgical Resection and Inferior Vena Cava Reconstruction for Treatment of the Malignant Tumor: Technical Success and Outcomes

    PubMed Central

    2014-01-01

    Objective: The purpose of this study was to review patients who underwent inferior vena cava (IVC) resection with concomitant malignant tumor resection and to consider the operative procedures and the outcomes. Materials and Methods: Between 2000 and 2012, 41 patients underwent resection of malignant tumors concomitant with surgical resection of the IVC at our institute. The records of these patients were retrospectively reviewed. Results: Primary tumor resections included nephrectomy, hepatectomy, retroperitoneal tumor extirpation, lymph node dissection, and pancreaticoduodenectomy. The IVC interventions were partial resection in 23 patients and total resection in 18 patients. Four patients underwent IVC replacement. Operation-related complications included pulmonary embolism, acute myocardial infarction, deep vein thrombosis, leg edema and temporary hemodialysis. There were no operative deaths. The mean follow-up period was 24.9 months (range: 2–98 months). The prognosis depended on the type and stage of the tumor. Conclusion: Resection and reconstruction of the IVC can be performed safely if the preoperative evaluations and surgical procedures are performed properly. The IVC resection without reconstruction was permissive if the IVC was completely obstructed preoperatively, but it may also be considered in cases where the IVC is not completely obstructed. PMID:24995055

  14. The electrolytic inferior vena cava model (EIM) to study thrombogenesis and thrombus resolution with continuous blood flow in the mouse

    PubMed Central

    Diaz, Jose A.; Alvarado, Christine M.; Wrobleski, Shirley K.; Slack, Dallas W.; Hawley, Angela E.; Farris, Diana M.; Henke, Peter K.; Wakefield, Thomas W.; Myers, Daniel D.

    2016-01-01

    Summary Previously, we presented the electrolytic inferior vena cava (IVC) model (EIM) during acute venous thrombosis (VT). Here, we present our evaluation of the EIM for chronic VT time points in order to determine whether this model allows for the study of thrombus resolution. C57BU6 mice (n=191) were utilised. In this model a copper-wire, inserted into a 25-gauge needle, is placed in the distal IVC and another subcutaneously. An electrical current (250 µAmp/15 minutes) activates the endothelial cells, inducing thrombogenesis. Ultrasound, thrombus weight (TW), vein wall leukocyte counts, vein wall thickness/fibrosis scoring, thrombus area and soluble P-selectin (sP-sel) were performed at baseline, days 1, 2, 4, 6, 9, 11 and 14, post EIM. A correlation between TW and sP-sel was also determined. A thrombus formed in each mouse undergoing EIM. Blood flow was documented by ultrasound at all time points. IVC thrombus size increased up to day 2 and then decreased over time, as shown by ultrasound, TW, and sP-sel levels. TW and sP-sel showed a strong positive correlation (r=0.48, p<0.0002). Vein wall neutrophils were the most common cell type present in acute VT (up to day 2) with monocytes becoming the most prevalent in chronic VT (from day 6 to day 14). Thrombus resolution was demonstrated by ultrasound, TW and thrombus area. In conclusion, the EIM produces a non-occlusive and consistent IVC thrombus, in the presence of constant blood flow, allowing for the study of VT at both acute and chronic time points. Thrombus resolution was demonstrated by all modalities utilised in this study. PMID:23571406

  15. Incarvine C suppresses proliferation and vasculogenic mimicry of hepatocellular carcinoma cells via targeting ROCK inhibition.

    PubMed

    Zhang, Ji-Gang; Zhang, Dan-Dan; Wu, Xin; Wang, Yu-Zhu; Gu, Sheng-Ying; Zhu, Guan-Hua; Li, Xiao-Yu; Li, Qin; Liu, Gao-Lin

    2015-10-28

    Studies have described vasculogenic mimicry (VM) as an alternative circulatory system to blood vessels in multiple malignant tumor types, including hepatocellular carcinoma (HCC). In the current study, we aimed to seek novel and more efficient treatment strategies by targeting VM and explore the underlying mechanisms in HCC cells. Cell counting kit-8 (CCK-8) assay and colony survival assay were performed to explore the inhibitory effect of incarvine C (IVC) on human cancer cell proliferation. Flow cytometry was performed to analyze the cell cycle distribution after DNA staining and cell apoptosis by the Annexin V-PE and 7-AAD assay. The effect of IVC on Rho-associated, coiled-coil-containing protein kinase (ROCK) was determined by western blotting and stress fiber formation assay. The inhibitory role of IVC on MHCC97H cell VM formation was determined by formation of tubular network structures on Matrigel in vitro, real time-qPCR, confocal microscopy and western blotting techniques. We explored an anti-metastatic HCC agent, IVC, derived from traditional Chinese medicinal herbs, and found that IVC dose-dependently inhibited the growth of MHCC97H cells. IVC induced MHCC97H cell cycle arrest at G1 transition, which was associated with cyclin-dependent kinase 2 (CDK-2)/cyclin-E1 degradation and p21/p53 up-regulation. In addition, IVC induced apoptotic death of MHCC97H cells. Furthermore, IVC strongly suppressed the phosphorylation of the ROCK substrate myosin phosphatase target subunit-1 (MYPT-1) and ROCK-mediated actin fiber formation. Finally, IVC inhibited cell-dominant tube formation in vitro, which was accompanied with the down-regulation of VM-key factors as detected by real time-qPCR and immunofluorescence. Taken together, the effective inhibitory effect of IVC on MHCC97H cell proliferation and neovascularization was associated with ROCK inhibition, suggesting that IVC may be a new potential drug candidate for the treatment of HCC.

  16. Complications of Celect, Günther tulip, and Greenfield inferior vena cava filters on CT follow-up: a single-institution experience.

    PubMed

    McLoney, Eric D; Krishnasamy, Venkatesh P; Castle, Jordan C; Yang, Xiangyu; Guy, Gregory

    2013-11-01

    To evaluate and compare the rates of complications on follow-up computed tomography (CT) studies of patients with Celect, Günther Tulip, and Greenfield inferior vena cava (IVC) filters. Retrospective review of CT studies obtained 0-1,987 days after infrarenal placement of an IVC filter identified 255 Celect, 160 Tulip, and 50 Greenfield filters. Follow-up CT studies were independently evaluated by two observers for IVC perforation, contact with adjacent organs, and filter fracture. Multivariate analysis was performed to identify factors associated with higher rates of IVC perforation, including age, IVC diameter, sex, and history of malignancy. IVC perforation was observed in 126 of 255 Celect filters (49%) with a mean follow-up of 277 days, 69 of 160 Tulip filters (43%) with a mean follow-up of 437 days, and one of 50 Greenfield filters (2%) with a mean follow-up of 286 days. A significantly higher IVC perforation rate was observed in women (45.5%) compared with men (30.8%; P = .002) and in patients with a history of malignancy (43.7%) compared with patients with no history of malignancy (29.9%; P < .001). Filter fracture was rare, observed in two of 255 Celect filters (0.8%), one of 160 Tulip filters (0.6%), and none of 50 Greenfield filters. No significant difference was observed in IVC perforation rate between Celect and Tulip filters. Greenfield filters had a significantly lower rate of IVC perforation than Celect and Tulip filters. Higher IVC perforation rates were observed in women and patients with a history of malignancy. © SIR, 2013.

  17. Creation of an iOS and Android Mobile Application for Inferior Vena Cava (IVC) Filters: A Powerful Tool to Optimize Care of Patients with IVC Filters

    PubMed Central

    Deso, Steven E.; Idakoji, Ibrahim A.; Muelly, Michael C.; Kuo, William T.

    2016-01-01

    Owing to a myriad of inferior vena cava (IVC) filter types and their potential complications, rapid and correct identification may be challenging when encountered on routine imaging. The authors aimed to develop an interactive mobile application that allows recognition of all IVC filters and related complications, to optimize the care of patients with indwelling IVC filters. The FDA Premarket Notification Database was queried from 1980 to 2014 to identify all IVC filter types in the United States. An electronic search was then performed on MEDLINE and the FDA MAUDE database to identify all reported complications associated with each device. High-resolution photos were taken of each filter type and corresponding computed tomographic and fluoroscopic images were obtained from an institutional review board–approved IVC filter registry. A wireframe and storyboard were created, and software was developed using HTML5/CSS compliant code. The software was deployed using PhoneGap (Adobe, San Jose, CA), and the prototype was tested and refined. Twenty-three IVC filter types were identified for inclusion. Safety data from FDA MAUDE and 72 relevant peer-reviewed studies were acquired, and complication rates for each filter type were highlighted in the application. Digital photos, fluoroscopic images, and CT DICOM files were seamlessly incorporated. All data were succinctly organized electronically, and the software was successfully deployed into Android (Google, Mountain View, CA) and iOS (Apple, Cupertino, CA) platforms. A powerful electronic mobile application was successfully created to allow rapid identification of all IVC filter types and related complications. This application may be used to optimize the care of patients with IVC filters. PMID:27247483

  18. Creation of an iOS and Android Mobile Application for Inferior Vena Cava (IVC) Filters: A Powerful Tool to Optimize Care of Patients with IVC Filters.

    PubMed

    Deso, Steven E; Idakoji, Ibrahim A; Muelly, Michael C; Kuo, William T

    2016-06-01

    Owing to a myriad of inferior vena cava (IVC) filter types and their potential complications, rapid and correct identification may be challenging when encountered on routine imaging. The authors aimed to develop an interactive mobile application that allows recognition of all IVC filters and related complications, to optimize the care of patients with indwelling IVC filters. The FDA Premarket Notification Database was queried from 1980 to 2014 to identify all IVC filter types in the United States. An electronic search was then performed on MEDLINE and the FDA MAUDE database to identify all reported complications associated with each device. High-resolution photos were taken of each filter type and corresponding computed tomographic and fluoroscopic images were obtained from an institutional review board-approved IVC filter registry. A wireframe and storyboard were created, and software was developed using HTML5/CSS compliant code. The software was deployed using PhoneGap (Adobe, San Jose, CA), and the prototype was tested and refined. Twenty-three IVC filter types were identified for inclusion. Safety data from FDA MAUDE and 72 relevant peer-reviewed studies were acquired, and complication rates for each filter type were highlighted in the application. Digital photos, fluoroscopic images, and CT DICOM files were seamlessly incorporated. All data were succinctly organized electronically, and the software was successfully deployed into Android (Google, Mountain View, CA) and iOS (Apple, Cupertino, CA) platforms. A powerful electronic mobile application was successfully created to allow rapid identification of all IVC filter types and related complications. This application may be used to optimize the care of patients with IVC filters.

  19. Hospitalists' ability to use hand-carried ultrasound for central venous pressure estimation after a brief training intervention: a pilot study.

    PubMed

    Martin, L David; Ziegelstein, Roy C; Howell, Eric E; Martire, Carol; Hellmann, David B; Hirsch, Glenn A

    2013-12-01

    Access to hand-carried ultrasound technology for noncardiologists has increased significantly, yet development and evaluation of training programs are limited. We studied a focused program to teach hospitalists image acquisition of inferior vena cava (IVC) diameter and IVC collapsibility index with interpretation of estimated central venous pressure (CVP). Ten hospitalists completed an online educational module prior to attending a 1-day in-person training session that included directly supervised IVC imaging on volunteer subjects. In addition to making quantitative assessments, hospitalists were also asked to visually assess whether the IVC collapsed more than 50% during rapid inspiration or a sniff maneuver. Skills in image acquisition and interpretation were assessed immediately after training on volunteer patients and prerecorded images, and again on volunteer patients at least 6 weeks later. Eight of 10 hospitalists acquired adequate IVC images and interpreted them correctly on 5 of the 5 volunteer subjects and interpreted all 10 prerecorded images correctly at the end of the 1-day training session. At 7.4 ± 0.7 weeks (range, 6.9-8.6 weeks) follow-up, 9 of 10 hospitalists accurately acquired and interpreted all IVC images in 5 of 5 volunteers. Hospitalists were also able to accurately determine whether the IVC collapsibility index was more than 50% by visual assessment in 180 of 198 attempts (91% of the time). After a brief training program, hospitalists acquired adequate skills to perform and interpret hand-carried ultrasound IVC images and retained these skills in the near term. Though calculation of the IVC collapsibility index is more accurate, coupling a qualitative assessment with the IVC maximum diameter measurement may be acceptable in aiding bedside estimation of CVP. © 2013 Society of Hospital Medicine.

  20. Flat inferior vena cava: indicator of poor prognosis in trauma and acute care surgery patients.

    PubMed

    Ferrada, Paula; Vanguri, Poornima; Anand, Rahul J; Whelan, James; Duane, Therese; Wolfe, Luke; Ivatury, Rao

    2012-12-01

    Flat inferior vena cava (IVC) on ultrasound examination has been shown to correlate with hypovolemic status. We hypothesize that a flat IVC on limited echocardiogram (LTTE) performed in the emergency room (ER) correlates with poor prognosis in acutely ill surgical patients. We conducted a retrospective review of all patients undergoing LTTE in the ER from September 2010 until June 2011. IVC diameter was estimated by subxiphoid window. Flat IVC was defined as diameter less than 2 cm. Fat IVC was defined as diameter greater than 2 cm. Need for intensive care unit admission, blood transfusion requirement, mortality, and need for emergent operation between patients with flat versus Fat IVC were compared. One hundred one hypotensive patients had LTTE performed in the ER. Average age was 38 years. Admission diagnosis was blunt trauma (n = 80), penetrating trauma (n = 13), acute care surgery pathology (n = 7), and burn (n = 1). Seventy-four patients had flat IVC on initial LTTE. Compared with those with fat IVC, flat patients were found have higher rates of intensive care unit admission (51.3 vs 14.8%; P = 0.001), blood transfusion requirement (12.2 vs 3.7%), and mortality (13.5 vs 3.7%). This population also underwent emergent surgery on hospital Day 1 more often (16.2 vs 0%; P = 0.033). Initial flat IVC on LTTE is an indicator of hypovolemia and a predictor of poor outcome.

  1. Intravitreal Conbercept Injection with and without Grid Laser Photocoagulation in the Treatment of Diffuse Diabetic Macular Edema in Real-Life Clinical Practice.

    PubMed

    Xu, Yule; Rong, Ao; Bi, Yanlong; Xu, Wei

    2016-01-01

    Purpose . To evaluate the efficacy of intravitreal conbercept (IVC) plus modified grid laser photocoagulation (MGP) versus IVC alone for treatment of diffuse diabetic macular edema (DDME). Methods. In this retrospective study, 51 DDME patients were treated with either IVC alone (IVC group) or IVC plus MGP (combined group) with 12 months of follow-up. The clinical records of those patients were reviewed. Results. 26 patients (31 eyes) received IVC alone and 25 patients (30 eyes) received combined therapy. At month 12, the mean best-corrected visual acuity (BCVA) letter score improvement was 9.1 ± 4.5 and 7.5 ± 4.2 in the IVC group and the combined group and the mean central retinal thickness (CRT) reduction was 145.1 ± 69.9  μ m and 168.5 ± 53.6  μ m, respectively. There was no statistically significant difference of improvement in BCVA ( P = 0.164) and decrease in CRT ( P = 0.149) between the two groups. The mean number of injections delivered was significantly higher ( P < 0.001) in the IVC group (5.6 ± 0.8 per eye) than in the combined group (3.3 ± 1.2 per eye). Conclusions . IVC alone or combined with MGP appeared to be effective for treatment of DDME, achieving the similar clinical efficacy. Moreover, MGP helps to reduce the number of injections.

  2. Effects of acoustic treatment on the interior noise levels of a twin-engine propeller aircraft - Experimental flight results and theoretical predictions

    NASA Technical Reports Server (NTRS)

    Beyer, T. B.; Powell, C. A.; Daniels, E. F.; Pope, L. D.

    1984-01-01

    In-flight noise level measurements were made within two cabin configurations of a general aviation business aircraft. The Fairchild Merlin IVC twin-engine aircraft was tested with bare walls and fiberglass insulation and in an executive trim configuration. Narrow-band and octave format data were subjected to analyses which permitted identification of the blade passage harmonics (BPH). Cabin noise level reductions (insertion losses) due to added insulation varied with position in the cabin, the BPH number, cabin pressure, and engine torque. The measurements were closely predicted using the propeller aircraft interior noise (PAIN) mode.

  3. Cyanoacrylate tissue adhesives - effective securement technique for intravascular catheters: in vitro testing of safety and feasibility.

    PubMed

    Simonova, G; Rickard, C M; Dunster, K R; Smyth, D J; McMillan, D; Fraser, J F

    2012-05-01

    Partial or complete dislodgement of intravascular catheters remains a significant problem in hospitals despite current securement methods. Cyanoacrylate tissue adhesives (TA) are used to close skin wounds as an alternative to sutures. These adhesives have high mechanical strength and can remain in situ for several days. This study investigated in vitro use of TAs in securing intravascular catheters (IVC). We compared two adhesives for interaction with IVC material, comparing skin glues with current securement methods in terms of their ability to prevent IVC dislodgement and inhibit microbial growth. Two TAs (Dermabond, Ethicon Inc. and Histoacryl, B. Braun) and three removal agents (Remove™, paraffin and acetone) were tested for interaction with IVC material by use of tensile testing. TAs were also compared against two polyurethane (standard and bordered) dressings (Tegaderm™ 1624 and 1633, 3M Australia Pty Ltd) and an external stabilisation device (Statlock, Bard Medical, Covington) against control (unsecured IVCs) for ability to prevent pull-out of 16 G peripheral IVCs from newborn fresh porcine skin. Agar media containing pH-sensitive dye was used to assess antimicrobial properties of TAs and polyurethane dressings to inhibit growth of Staphylococcus aureus and Staphylococcus epidermidis. Neither TA weakened the IVCs (P >0.05). Of removal agents, only acetone was associated with a significant decrease in IVC strength (P <0.05). Both TAs and Statlock significantly increased the pull-out force (P <0.01). TA was quick and easy to apply to IVCs, with no irritation or skin damage noted on removal and no bacterial colony growth under either TA.

  4. A Retrospective Evaluation of Echocardiograms to Establish Normative Inferior Vena Cava and Aortic Measurements for Children Younger Than 6 Years.

    PubMed

    Stenson, Erin K; Punn, Rajesh; Ramsi, Musaab; Kache, Saraswati

    2018-02-26

    The ability to plot the inferior vena cava (IVC) size on a normal curve for pediatric patients may prove beneficial. First, in patients with normal cardiac anatomy who present in shock, assessing IVC size may be valuable for evaluating the degree of dehydration. Second, in children with heart disease, understanding how a child's IVC size compares to normal could be particularly beneficial for patients with right heart disease. We sought to create normal curves for the IVC and aorta in children younger than 6 years. Data were gathered from 347 echocardiograms of healthy children younger than 6 years in a retrospective study at a quaternary care children's hospital. From the subcostal long- and short-axis images, maximum diameters in the transverse and longitudinal views were obtained for both the IVC and the aorta. Both IVC and aortic dimensions increased in a linear fashion and had excellent correlations with the body surface area, body mass, and height (IVC, r = 0.78-0.81; P < .0001; aorta, r = 0.82-0.86; P < .0001). In children younger than 6 years, the IVC and aorta increase linearly as the children grow. Such normal curves will be beneficial for assessing a pediatric patient's hydration status or right heart function in patients with congenital heart disease. © 2018 by the American Institute of Ultrasound in Medicine.

  5. Worldwide human papillomavirus genotype attribution in over 2000 cases of intraepithelial and invasive lesions of the vulva.

    PubMed

    de Sanjosé, Silvia; Alemany, Laia; Ordi, Jaume; Tous, Sara; Alejo, Maria; Bigby, Susan M; Joura, Elmar Armin; Maldonado, Paula; Laco, Jan; Bravo, Ignacio G; Vidal, August; Guimerà, Núria; Cross, Paul; Wain, Gerard V; Petry, Karl Ulrich; Mariani, Luciano; Bergeron, Christine; Mandys, Václav; Sica, Adela Rosa; Félix, Ana; Usubutun, Alp; Seoud, Muhieddine; Hernández-Suárez, Gustavo; Nowakowski, Andrzej Marcin; Wilson, Godfrey; Dalstein, Veronique; Hampl, Monika; Kasamatsu, Elena Sachiko; Lombardi, Luis Estuardo; Tinoco, Leopoldo; Alvarado-Cabrero, Isabel; Perrotta, Myriam; Bhatla, Neerja; Agorastos, Theodoros; Lynch, Charles F; Goodman, Marc T; Shin, Hai-Rim; Viarheichyk, Halina; Jach, Robert; Cruz, M O L Eugenia; Velasco, Julio; Molina, Carla; Bornstein, Jacob; Ferrera, Annabelle; Domingo, Efren Javier; Chou, Cheng-Yang; Banjo, Adekunbiola F; Castellsagué, Xavier; Pawlita, Michael; Lloveras, Belén; Quint, Wim G V; Muñoz, Nubia; Bosch, F Xavier

    2013-11-01

    Human papillomavirus (HPV) contribution in vulvar intraepithelial lesions (VIN) and invasive vulvar cancer (IVC) is not clearly established. This study provides novel data on HPV markers in a large series of VIN and IVC lesions. Histologically confirmed VIN and IVC from 39 countries were assembled at the Catalan Institute of Oncology (ICO). HPV-DNA detection was done by polymerase chain reaction using SPF-10 broad-spectrum primers and genotyping by reverse hybridisation line probe assay (LiPA25) (version 1). IVC cases were tested for p16(INK4a) by immunohistochemistry (CINtec histology kit, ROCHE). An IVC was considered HPV driven if both HPV-DNA and p16(INK4a) overexpression were observed simultaneously. Data analyses included algorithms allocating multiple infections to calculate type-specific contribution and logistic regression models to estimate adjusted prevalence (AP) and its 95% confidence intervals (CI). Of 2296 cases, 587 were VIN and 1709 IVC. HPV-DNA was detected in 86.7% and 28.6% of the cases respectively. Amongst IVC cases, 25.1% were both HPV-DNA and p16(INK4a) positive. IVC cases were largely keratinising squamous cell carcinoma (KSCC) (N=1234). Overall prevalence of HPV related IVC cases was highest in younger women for any histological subtype. SCC with warty or basaloid features (SCC_WB) (N=326) were more likely to be HPV and p16(INK4a) positive (AP=69.5%, CI=63.6-74.8) versus KSCC (AP=11.5%, CI=9.7-13.5). HPV 16 was the commonest type (72.5%) followed by HPV 33 (6.5%) and HPV 18 (4.6%). Enrichment from VIN to IVC was significantly high for HPV 45 (8.5-fold). Combined data from HPV-DNA and p16(INK4a) testing are likely to represent a closer estimate of the real fraction of IVC induced by HPV. Our results indicate that HPV contribution in invasive vulvar cancer has probably been overestimated. HPV 16 remains the major player worldwide. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. A resolved two-way coupled CFD/6-DOF approach for predicting embolus transport and the embolus-trapping efficiency of IVC filters.

    PubMed

    Aycock, Kenneth I; Campbell, Robert L; Manning, Keefe B; Craven, Brent A

    2017-06-01

    Inferior vena cava (IVC) filters are medical devices designed to provide a mechanical barrier to the passage of emboli from the deep veins of the legs to the heart and lungs. Despite decades of development and clinical use, IVC filters still fail to prevent the passage of all hazardous emboli. The objective of this study is to (1) develop a resolved two-way computational model of embolus transport, (2) provide verification and validation evidence for the model, and (3) demonstrate the ability of the model to predict the embolus-trapping efficiency of an IVC filter. Our model couples computational fluid dynamics simulations of blood flow to six-degree-of-freedom simulations of embolus transport and resolves the interactions between rigid, spherical emboli and the blood flow using an immersed boundary method. Following model development and numerical verification and validation of the computational approach against benchmark data from the literature, embolus transport simulations are performed in an idealized IVC geometry. Centered and tilted filter orientations are considered using a nonlinear finite element-based virtual filter placement procedure. A total of 2048 coupled CFD/6-DOF simulations are performed to predict the embolus-trapping statistics of the filter. The simulations predict that the embolus-trapping efficiency of the IVC filter increases with increasing embolus diameter and increasing embolus-to-blood density ratio. Tilted filter placement is found to decrease the embolus-trapping efficiency compared with centered filter placement. Multiple embolus-trapping locations are predicted for the IVC filter, and the trapping locations are predicted to shift upstream and toward the vessel wall with increasing embolus diameter. Simulations of the injection of successive emboli into the IVC are also performed and reveal that the embolus-trapping efficiency decreases with increasing thrombus load in the IVC filter. In future work, the computational tool could be used to investigate IVC filter design improvements, the effect of patient anatomy on embolus transport and IVC filter embolus-trapping efficiency, and, with further development and validation, optimal filter selection and placement on a patient-specific basis.

  7. Outcomes after inferior vena cava filter placement in cancer patients diagnosed with pulmonary embolism: risk for recurrent venous thromboembolism.

    PubMed

    Coombs, Catherine; Kuk, Deborah; Devlin, Sean; Siegelbaum, Robert H; Durack, Jeremy C; Parameswaran, Rekha; Mantha, Simon; Deng, Kathy; Soff, Gerald

    2017-11-01

    Venous thromboembolism (VTE) is a common complication in cancer patients and anticoagulation (AC) remains the standard of care for treatment. Inferior vena cava (IVC) filters may also used to reduce the risk of pulmonary embolism, either alone or in addition to AC. Although widely used, data are limited on the safety and efficacy of IVC filters in cancer patients. We performed a retrospective review of outcomes after IVC filter insertion in a database of 1270 consecutive patients with cancer-associated pulmonary embolism (PE) at our institution between 2008 and 2009. Outcomes measured included rate of all recurrent VTE, recurrent PE, and overall survival within 12 months. 317 (25%) of the 1270 patients with PE had IVC filters placed within 30 days of the index PE event or prior to the index PE in the setting of prior DVT. Patients with IVC filters had markedly lower overall survival (7.3 months) than the non-IVC filter patients (13.2 months). Filter patients also had a lower rate of AC use at time of initial PE. There was a trend towards higher recurrent VTE in patients with IVC filters (11.9%) compared to non-filter patients (7.7%), but this was not significant (p = 0.086). The risk of recurrent PE was similar between the IVC filter cohort (3.5%) and non-filter group (3.5%, p = 0.99). Cancer patients receiving IVC filters had a similar risk of recurrent PE, but a trend towards more overall recurrent VTE. The filter patients had poorer overall survival, which may reflect a poorer cancer prognosis, and had greater contraindication to AC; therefore these patients likely had a higher inherent risk for recurrent VTE. A prospective study would be helpful for further clarification on the partial reduction in the recurrent PE risk by IVC filter placement in cancer patients.

  8. Outcome of inferior vena cava and noncaval venous leiomyosarcomas.

    PubMed

    Illuminati, Giulio; Pizzardi, Giulia; Calio', Francesco; Pacilè, Maria Antonietta; Masci, Federica; Vietri, Francesco

    2016-02-01

    Leiomyosarcoma (LMS) is a rare tumor arising from the smooth muscle cells of arteries and veins. LMS may affect both the inferior vena cava (IVC) and non-IVC veins. Because of its rarity, the experience with the outcome of the disease originating from the IVC compared with that with non-IVC offspring is overall limited. In this study, we compared the clinical features and outcomes after operative resection of IVC and non-IVC LMS to detect possible significant differences that could affect treatment and prognosis. Twenty-seven patients undergoing operative resection of a venous LMS at a single tertiary care center and one secondary care hospital were reviewed retrospectively and divided into 2 groups: IVC-LMS (Group A, n = 18) and non-IVC LMS (Group B, n = 9). As primary end points, postoperative mortality and morbidity, disease-specific survival and, if applicable, patency of venous reconstruction were considered. Bivariate differences were compared with the χ(2) test. Disease-specific survival was expressed by a life-table analysis and compared using the log-rank test. No postoperative mortality was observed in either group. Postoperative morbidity was 28% in group A and 11% in group B (P = .33). The mean duration of follow-up was 60 months (range, 13-140). Disease-specific survival was 60% in group A and 75% in group B at 3 years (P = .48), and it was 54% in group A and 62% in group B at 5 years (P = .63). Seven grafts were occluded in group A (39%) and 1of 3 were occluded in group B (33%) (P = .85). IVC and non-IVC LMS exhibit similar outcomes in terms of postoperative course and survival. Operative resection associated with vascular reconstruction, if applicable, eventually followed by radiation and chemotherapy may be curative and is associated with good functional results. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Individually ventilated cages cause chronic low-grade hypoxia impacting mice hematologically and behaviorally

    PubMed Central

    York, Jason M.; McDaniel, Allison W.; Blevins, Neil A.; Guillet, Riley R.; Allison, Sarah O.; Cengel, Keith A.; Freund, Gregory G.

    2012-01-01

    Use of individually ventilated caging (IVC) systems for mouse-based laboratory investigation has dramatically increased. We found that without mice present, intra-cage oxygen concentration was comparable (21%) between IVC housing and ambient environment caging (AEC) that used wire top lids. However, when mice were housed 4-to-a-cage for 1 week, intra-cage oxygen dropped to 20.5% in IVC housing as compared to 21% for AEC housing. IVC intra-cage humidity was also elevated relative to AEC housing. Mice raised in IVC housing as compared to mice raised in AEC housing had higher RBC mass, hematocrit and hemoglobin concentrations. They also had elevated platelet counts but lower white blood cell counts. IVC mice relative to AEC mice had increased saccharin preference and increased fluid consumption but similar locomotion, food intake, social exploration and novel object recognition when tested in an AEC environment. Taken together, these data indicate that ventilated caging systems can have a 0.5% reduction from ambient oxygen concentration that is coupled to mouse red blood cell indices indicative of chronic exposure to a hypoxia. Importantly, IVC housing can impact behavioral testing for depressive-like behavior. PMID:22561683

  10. Relative incidence of phlebitis associated with peripheral intravenous catheters in the lower versus upper extremities.

    PubMed

    Benaya, A; Schwartz, Y; Kory, R; Yinnon, A M; Ben-Chetrit, E

    2015-05-01

    Peripheral venous access in elderly, hospitalized patients is often challenging. The usual alternative is insertion of a central venous catheter, with associated risk for complications. The purpose of this investigation was to determine the relative incidence of phlebitis secondary to lower as compared to upper extremity intravenous catheters (IVCs) and associated risk factors. A non-randomized, observational, cohort-controlled study was carried out. Consecutive patients receiving a lower extremity IVC were enrolled and compared with patients receiving an upper extremity IVC. Patients were followed from insertion until removal of the IVC. The major endpoint was phlebitis. The incidence of phlebitis secondary to upper extremity IVCs was 3/50 (6 %) compared to 5/53 (9.4 %) in lower extremity IVCs (χ(2) Yates = 0.08, p = 0.776). Age, gender, obesity, diabetes mellitus, site (arm versus leg, left versus right), and size of needle were not found to be risk factors for phlebitis according to univariate analysis. None of the patients developed bloodstream infection. In elderly patients with poor venous access, lower extremity IVCs are a reasonable and low-risk alternative to central venous catheters.

  11. Perforation of the IVC: rule rather than exception after longer indwelling times for the Günther Tulip and Celect retrievable filters.

    PubMed

    Durack, Jeremy C; Westphalen, Antonio C; Kekulawela, Stephanie; Bhanu, Shiv B; Avrin, David E; Gordon, Roy L; Kerlan, Robert K

    2012-04-01

    This study was designed to assess the incidence, magnitude, and impact upon retrievability of vena caval perforation by Günther Tulip and Celect conical inferior vena cava (IVC) filters on computed tomographic (CT) imaging. Günther Tulip and Celect IVC filters placed between July 2007 and May 2009 were identified from medical records. Of 272 IVC filters placed, 50 (23 Günther Tulip, 46%; 27 Celect, 54%) were retrospectively assessed on follow-up abdominal CT scans performed for reasons unrelated to the filter. Computed tomography scans were examined for evidence of filter perforation through the vena caval wall, tilt, or pericaval tissue injury. Procedure records were reviewed to determine whether IVC filter retrieval was attempted and successful. Perforation of at least one filter component through the IVC was observed in 43 of 50 (86%) filters on CT scans obtained between 1 and 880 days after filter placement. All filters imaged after 71 days showed some degree of vena caval perforation, often as a progressive process. Filter tilt was seen in 20 of 50 (40%) filters, and all tilted filters also demonstrated vena caval perforation. Transjugular removal was attempted in 12 of 50 (24%) filters and was successful in 11 of 12 (92%). Longer indwelling times usually result in vena caval perforation by retrievable Günther Tulip and Celect IVC filters. Although infrequently reported in the literature, clinical sequelae from IVC filter components breaching the vena cava can be significant. We advocate filter retrieval as early as clinically indicated and increased attention to the appearance of IVC filters on all follow-up imaging studies.

  12. Perforation of the IVC: Rule Rather Than Exception After Longer Indwelling Times for the Guenther Tulip and Celect Retrievable Filters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Durack, Jeremy C., E-mail: jeremy.durack@ucsf.edu; Westphalen, Antonio C.; Kekulawela, Stephanie

    Purpose: This study was designed to assess the incidence, magnitude, and impact upon retrievability of vena caval perforation by Guenther Tulip and Celect conical inferior vena cava (IVC) filters on computed tomographic (CT) imaging. Methods: Guenther Tulip and Celect IVC filters placed between July 2007 and May 2009 were identified from medical records. Of 272 IVC filters placed, 50 (23 Guenther Tulip, 46%; 27 Celect, 54%) were retrospectively assessed on follow-up abdominal CT scans performed for reasons unrelated to the filter. Computed tomography scans were examined for evidence of filter perforation through the vena caval wall, tilt, or pericaval tissuemore » injury. Procedure records were reviewed to determine whether IVC filter retrieval was attempted and successful. Results: Perforation of at least one filter component through the IVC was observed in 43 of 50 (86%) filters on CT scans obtained between 1 and 880 days after filter placement. All filters imaged after 71 days showed some degree of vena caval perforation, often as a progressive process. Filter tilt was seen in 20 of 50 (40%) filters, and all tilted filters also demonstrated vena caval perforation. Transjugular removal was attempted in 12 of 50 (24%) filters and was successful in 11 of 12 (92%). Conclusions: Longer indwelling times usually result in vena caval perforation by retrievable Guenther Tulip and Celect IVC filters. Although infrequently reported in the literature, clinical sequelae from IVC filter components breaching the vena cava can be significant. We advocate filter retrieval as early as clinically indicated and increased attention to the appearance of IVC filters on all follow-up imaging studies.« less

  13. Initial experience using the rigid forceps technique to remove wall-embedded IVC filters.

    PubMed

    Avery, Allan; Stephens, Maximilian; Redmond, Kendal; Harper, John

    2015-06-01

    Severely tilted and embedded inferior vena cava (IVC) filters remain the most challenging IVC filters to remove. Heavy endothelialisation over the filter hook can prevent engagement with standard snare and cone recovery techniques. The rigid forceps technique offers a way to dissect the endothelial cap and reliably retrieve severely tilted and embedded filters. By developing this technique, failed IVC retrieval rates can be significantly reduced and the optimum safety profile offered by temporary filters can be achieved. We present our initial experience with the rigid forceps technique described by Stavropoulos et al. for removing wall-embedded IVC filters. We retrospectively reviewed the medical imaging and patient records of all patients who underwent a rigid forceps filter removal over a 22-month period across two tertiary referral institutions. The rigid forceps technique had a success rate of 85% (11/13) for IVC filter removals. All filters in the series showed evidence of filter tilt and embedding of the filter hook into the IVC wall. Average filter tilt from the Z-axis was 19 degrees (range 8-56). Filters observed in the case study were either Bard G2X (n = 6) or Cook Celect (n = 7). Average filter dwell time was 421 days (range 47-1053). There were no major complications observed. The rigid forceps technique can be readily emulated and is a safe and effective technique to remove severely tilted and embedded IVC filters. The development of this technique across both institutions has increased the successful filter removal rate, with perceived benefits to the safety profile of our IVC filter programme. © 2015 The Royal Australian and New Zealand College of Radiologists.

  14. Use of ultrasound measurement of the inferior vena cava diameter as an objective tool in the assessment of children with clinical dehydration.

    PubMed

    Chen, Lei; Kim, Yunie; Santucci, Karen A

    2007-10-01

    Bedside ultrasonography (US) measurement of the inferior vena cava (IVC) and aorta (Ao) may be useful in objectively assessing children with dehydration. The objectives of this study were 1) to compare the IVC and Ao diameters (IVC/Ao) ratio of dehydrated children with controls and 2) to compare the IVC/Ao ratio before and after intravenous (i.v.) rehydration in children with dehydration. This prospective observational study was performed in an urban pediatric emergency department. Children between 6 months and 16 years of age with clinical evidence of dehydration were enrolled. Bedside US measurements of the IVC and Ao were taken before and immediately after i.v. fluids were administered. An age-, gender-, and weight-matched control without dehydration was enrolled for each subject. The IVC/Ao ratios of subjects and controls were compared using Wilcoxon signed rank test, as were the ratios before and after i.v. hydration for each subject. Thirty-six pairs of subjects and matched controls were enrolled. The IVC/Ao ratios in the subjects were lower as compared with controls (mean of 0.75 vs. 1.01), with a mean difference of 0.26 (95% confidence interval = 0.18 to 0.35). In subjects, the IVC/Ao ratios were significantly lower before i.v. hydration (mean of 0.75 vs. 1.09), with a mean difference of 0.34 (95% confidence interval = 0.29 to 0.39). As measured by bedside US measurement, the IVC/Ao ratio is lower in children clinically assessed to be dehydrated. Furthermore, it increases with administration of i.v. fluid boluses.

  15. [Leiomyosarcoma of the inferior vena cava: a case report and review].

    PubMed

    Yo, Toeki; Taoka, Rikiya; Hanasaki, Takeshi; Nakanishi, Yukako; Togo, Yoshikazu; Suzuki, Toru; Higuchi, Yoshihide; Zozumi, Masataka; Hirota, Seiichi; Kanematsu, Akihiro; Nojima, Michio; Yamamoto, Shingo

    2014-03-01

    A 37-year-old woman with an incidentally found abdominal mass was referred to our hospital. A fixed, non-tender mass was palpated in the right upper quadrum of her abdomen. There was no elevation of tumor markers. Computed tomography revealed a mass extending from the hepatic vein level to renal hilar level. The tumor completely obstructed the inferior vena cava (IVC). T1-weighted magnetic resonance imaging (MRI) showed that the mass was isointense with muscles. T2-weighted MRI image with contrast medium demonstrated collateral circulation. Upon diagnosis of the IVC tumor, we removed the right kidney and the tumor en bloc without reconstructing IVC. The tumor diameter was 11.6 × 5.5 × 4.7 cm. Pathological examination established a diagnosis of IVC leiomyosarcoma. She is alive without sign of recurrence after operation for seven months. There were 143 reports of IVC leiomyosarcoma in Japan. In 31% of them, IVC was not reconstructed.

  16. Percutaneous Retrieval of Permanent Inferior Vena Cava Filters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tamrazi, Anobel, E-mail: atamraz1@jhmi.edu; Wadhwa, Vibhor, E-mail: vwadhwa1@jhmi.edu; Holly, Brian, E-mail: bholly3@jhmi.edu

    PurposeTo evaluate the feasibility, risks, and techniques of percutaneous removal of permanent TrapEase and Simon Nitinol IVC filters.Materials and MethodsBetween August 2011 and August 2015, 12 patients (5 women, 7 men; age range, 26–75 years) underwent an attempt at percutaneous removal of permanent TrapEase (10) and Simon Nitinol (2) IVC filters due to a history of IVC filter complications or need for lifelong anticoagulation due to the filter. Medical records were reviewed for filter dwell time, presence of iliocaval deep venous thrombosis, procedural technique, and complications.ResultsFilter dwell times ranged from 7 days to 15 years (mean 5.1 years). Successful removal of permanent IVC filtersmore » was possible in 11 of 12 patients (91.6 %). In 1 patient, a chronically thrombosed IVC filter could not be removed despite laser sheath assistance, but was successfully recanalized with the PowerWire RF guidewire. In the failed retrieval attempt, a stent was placed through the chronically thrombosed IVC filter with restoration of in-line flow. One major complication of large venous groin hematoma was encountered.ConclusionsIn carefully selected patients, percutaneous removal of permanent IVC filters can be performed safely despite prolonged filter dwell times. Extraction of chronically embedded permanent IVC filters may be facilitated by jugular and femoral approaches, often with laser sheath assistance. Chronic filter thrombosis and caval scarring may increase the risk of retrieval failure.« less

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, Richard A.; Teitelbaum, George P.; Stanley, Philip

    Purpose: To report our experience with inferior vena cava (IVC) filters in pediatric patients. Methods: Over a 19-month period, eight low-profile percutaneously introducible IVC filters were placed in four male and four female patients aged 6-16 years (mean 11 years). Indications were contraindication to heparin in six patients, anticoagulation failure in one, and idiopathic infrarenal IVC thrombosis in one. Six of the eight devices placed were titanium Greenfield filters. One LGM and one Bird's Nest filter were also placed. Two of the filters were introduced via the right internal jugular vein by cutdown, and the remainder were placed percutaneously viamore » the right internal jugular vein or the right common femoral vein. Patients received follow-up abdominal radiographs from 2 to 13 months after IVC filter placement. Results: All filters were inserted successfully without complication. Three of the patients died during the follow-up period: two due to underlying brain tumors at 2 and 12 months and a third at 6 weeks due to progressive idiopathic renal vein and IVC thrombosis. The remaining five patients were all alive and well at follow-up without evidence of IVC thrombosis, pulmonary emboli, or filter migration. Conclusion: IVC filter placement using available devices for percutaneous delivery is technically feasible, safe, and effective in children.« less

  18. Imaging of the transplant liver.

    PubMed

    Babyn, Paul Sheppard

    2010-04-01

    As the number of patients with liver transplants continues to increase, radiologists need to be aware of the normal post-operative appearance of the different liver transplants currently performed along with the wide variety of complications encountered. The complications commonly affect the biliar and vascular systems and can include anastomotic bile leakage and biliary stenosis along with stenosis or obstruction of the hepatic artery, portal or hepatic veins and IVC. Other complications include parenchymal abnormalities such as hepatic infarction, organ rejection, localized collections and post transplant lymphoproliferative disorder. This article reviews and illustrates the role of imaging for pediatric transplantation including the role of interventional radiology.

  19. Use of bedside ultrasound to assess degree of dehydration in children with gastroenteritis.

    PubMed

    Chen, Lei; Hsiao, Allen; Langhan, Melissa; Riera, Antonio; Santucci, Karen A

    2010-10-01

    Prospectively identifying children with significant dehydration from gastroenteritis is difficult in acute care settings. Previous work by our group has shown that bedside ultrasound (US) measurement of the inferior vena cava (IVC) and the aorta (Ao) diameter ratio is correlated with intravascular volume. This study was designed to validate the use of this method in the prospective identification of children with dehydration by investigating whether the IVC/Ao ratio correlated with dehydration in children with acute gastroenteritis. Another objective was to investigate the interrater reliability of the IVC/Ao measurements. A prospective observational study was carried out in a pediatric emergency department (PED) between November 2007 and June 2009. Children with acute gastroenteritis were enrolled as subjects. A pair of investigators obtained transverse images of the IVC and Ao using bedside US. The ratio of IVC and Ao diameters (IVC/Ao) was calculated. Subjects were asked to return after resolution of symptoms. The difference between the convalescent weight and ill weight was used to calculate the degree of dehydration. Greater than or equal to 5% difference was judged to be significant. Linear regression was performed with dehydration as the dependent variable and the IVC/Ao as the independent variable. Pearson's correlation coefficient was calculated to assess the degree of agreement between observers. A total of 112 subjects were enrolled. Seventy-one subjects (63%) completed follow-up. Twenty-eight subjects (39%) had significant dehydration. The linear regression model resulted in an R² value of 0.21 (p < 0.001) and a slope (B) of 0.11 (95% confidence interval [CI] = 0.08 to 0.14). An IVC/Ao cutoff of 0.8 produced a sensitivity of 86% and a specificity of 56% for the diagnosis of significant dehydration. Forty-eight paired measurements of IVC/Ao ratios were made. The Pearson correlation coefficient was 0.76.   In this pilot study the ratio of IVC to Ao diameters, as measured by bedside US, was a marginally accurate measurement of acute weight loss in children with dehydration from gastroenteritis. The technique demonstrated good interrater reliability. © 2010 by the Society for Academic Emergency Medicine.

  20. Effects of abdominal pressure on venous return: abdominal vascular zone conditions.

    PubMed

    Takata, M; Wise, R A; Robotham, J L

    1990-12-01

    The effects of changes in abdominal pressure (Pab) on inferior vena cava (IVC) venous return were analyzed using a model of the IVC circulation based on a concept of abdominal vascular zone conditions analogous to pulmonary vascular zone conditions. We hypothesized that an increase in Pab would increase IVC venous return when the IVC pressure at the level of the diaphragm (Pivc) exceeds the sum of Pab and the critical closing transmural pressure (Pc), i.e., zone 3 conditions, but reduce IVC venous return when Pivc is below the sum of Pab and Pc, i.e., zone 2 conditions. The validity of the model was tested in 12 canine experiments with an open-chest IVC bypass. An increase in Pab produced by phrenic stimulation increased the IVC venous return when Pivc-Pab was positive but decreased the IVC venous return when Pivc - Pab was negative. The value of Pivc - Pab that separated net increases from decreases in venous return was 1.00 +/- 0.72 (SE) mmHg (n = 6). An increase in Pivc did not influence the femoral venous pressure when Pivc was lower than the sum of Pab and a constant, 0.96 +/- 0.70 mmHg (n = 6), consistent with presence of a waterfall. These results agreed closely with the predictions of the model and its computer simulation. The abdominal venous compartment appears to function with changes in Pab either as a capacitor in zone 3 conditions or as a collapsible Starling resistor with little wall tone in zone 2 conditions.

  1. 22 CFR 121.5 - Apparatus and devices under Category IV(c).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Apparatus and devices under Category IV(c). 121... UNITED STATES MUNITIONS LIST Enumeration of Articles § 121.5 Apparatus and devices under Category IV(c... units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and...

  2. Inferior vena cava filters.

    PubMed

    Duffett, L; Carrier, M

    2017-01-01

    Use of inferior vena cava (IVC) filters has increased dramatically in recent decades, despite a lack of evidence that their use has impacted venous thromboembolism (VTE)-related mortality. This increased use appears to be primarily driven by the insertion of retrievable filters for prophylactic indications. A growing body of evidence, however, suggests that IVC filters are frequently associated with clinically important adverse events, prompting a closer look at their role. We sought to narratively review the current evidence on the efficacy and safety of IVC filter placements. Inferior vena cava filters remain the only treatment option for patients with an acute (within 2-4 weeks) proximal deep vein thrombosis (DVT) or pulmonary embolism and an absolute contraindication to anticoagulation. In such patients, anticoagulation should be resumed and IVC filters removed as soon as the contraindication has passed. For all other indications, there is insufficient evidence to support the use of IVC filters and high-quality trials are required. In patients where an IVC filter remains, regular follow-up to reassess removal and screen for filter-related complications should occur. © 2016 International Society on Thrombosis and Haemostasis.

  3. [Clinical analysis of patients with lower extremity deep venous thrombosis complicated with inferior vena cava thrombus].

    PubMed

    Dong, Dian-ning; Wu, Xue-jun; Zhang, Shi-yi; Zhong, Zhen-yue; Jin, Xing

    2013-06-04

    To explore the clinical profiles of patients with lower extremity deep venous thrombosis (DVT) complicated with inferior vena cava (IVC) thrombus and summarize their clinical diagnostic and therapeutic experiences. The clinical characteristics, diagnosis and treatment of 20 hospitalized patients with DVT complicated with inferior vena cava thrombus were analyzed retrospectively. All of them were of proximal DVT. There were phlegmasia cerulea dolens (n = 3), pulmonary embolism (n = 3) and completely occlusion of IVC (n = 5). Clinical manifestations were severe. Retrievable inferior vena cava filter (IVCF) was implanted for 17 cases. Catheter-directed thrombolysis (CDT) through ipsilateral popliteal vein was applied for 7 cases and systemic thrombolysis therapy for 8 cases. The effective rate of thrombolysis for fresh IVC thrombus was 100%. Among 5 cases with Cockett Syndrome, 3 cases underwent balloon dilatation angioplasty and endovascular stenting of iliac vein. And 17 IVCFs were retrieved successfully within 3 weeks. IVC thrombus disappeared completely in 15 cases. Systemic or local thrombolysis with protective IVCF is a safe and effective therapy for nonocclusive IVC thrombus in DVT. And CDT is recommended for symptomatic occlusive IVC thrombus.

  4. Gefitinib in Treating Patients With Metastatic or Unresectable Head and Neck Cancer or Non-Small Cell Lung Cancer

    ClinicalTrials.gov

    2013-01-11

    Anaplastic Thyroid Cancer; Insular Thyroid Cancer; Metastatic Parathyroid Cancer; Recurrent Adenoid Cystic Carcinoma of the Oral Cavity; Recurrent Basal Cell Carcinoma of the Lip; Recurrent Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Recurrent Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Recurrent Lymphoepithelioma of the Nasopharynx; Recurrent Lymphoepithelioma of the Oropharynx; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Recurrent Mucoepidermoid Carcinoma of the Oral Cavity; Recurrent Non-small Cell Lung Cancer; Recurrent Parathyroid Cancer; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Thyroid Cancer; Recurrent Verrucous Carcinoma of the Larynx; Stage III Follicular Thyroid Cancer; Stage III Papillary Thyroid Cancer; Stage III Salivary Gland Cancer; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Larynx; Stage IIIB Non-small Cell Lung Cancer; Stage IV Lymphoepithelioma of the Nasopharynx; Stage IV Non-small Cell Lung Cancer; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVA Basal Cell Carcinoma of the Lip; Stage IVA Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Follicular Thyroid Cancer; Stage IVA Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Stage IVA Lymphoepithelioma of the Oropharynx; Stage IVA Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Stage IVA Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVA Papillary Thyroid Cancer; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVB Basal Cell Carcinoma of the Lip; Stage IVB Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Follicular Thyroid Cancer; Stage IVB Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Stage IVB Lymphoepithelioma of the Oropharynx; Stage IVB Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Stage IVB Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVB Papillary Thyroid Cancer; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVC Basal Cell Carcinoma of the Lip; Stage IVC Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Follicular Thyroid Cancer; Stage IVC Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Stage IVC Lymphoepithelioma of the Oropharynx; Stage IVC Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Stage IVC Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVC Papillary Thyroid Cancer; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Thryoid Gland Nonmedullary Carcinoma; Thyroid Gland Medullary Carcinoma; Tongue Cancer; Untreated Metastatic Squamous Neck Cancer With Occult Primary

  5. Incidence and Outcomes of Inferior Vena Cava Filter Thrombus during Catheter-directed Thrombolysis for Proximal Deep Venous Thrombosis.

    PubMed

    Jiang, Jianguang; Tu, Jianfei; Jia, Zhongzhi; Chen, Jiezhong; Cao, Haitao; Meng, Qingli; Fuller, Tyler A; Tian, Feng

    2017-01-01

    The aim of the study was to retrospectively evaluate the incidence and outcomes of inferior vena cava (IVC) filter thrombus during catheter-directed thrombolysis (CDT) for acute proximal deep venous thrombosis (DVT). From October 2006 to June 2015, patients diagnosed with acute proximal DVT and received CDT after a retrievable IVC filter was placed were included. The incidence, treatment, and outcomes of IVC filter thrombus during CDT were recorded and analyzed. A total of 189 patients (91 women, 98 men; mean age, 57.6 ± 9.8 years; range, 24-85 years) were included in this study. Among the 189 cases, the DVTs involved popliteal iliofemoral veins in 54 patients, iliofemoral veins in 113 patients, and iliac veins in 22 patients, of which 18 patients had thrombus extended into the IVC. Of the 189 patients, a total of 8 (4.2%, 8 of 189) patients were identified with IVC filter thrombus during CDT. The IVC filter thrombus was detected on a median of 2 days (range, 2-4 days) of CDT therapy, including small-size (n = 6) and large-size (n = 2) filter thrombus. Of the 8 patients, CDTs were performed with a mean 7.6 ± 1.1 days (range, 6-11 days) after the presence of symptoms for the treatment of proximal DVT, and all the IVC filter thrombi were lysed during CDT for the proximal DVT. All the IVC filters were removed successfully with a mean of 12.8 ± 0.93 days from placement. There were no procedure- or thrombolysis-related major complications, and no symptomatic pulmonary embolism breakthrough was seen in any of the patients after the filter placement. IVC filter thrombus during CDT for the acute proximal DVT is uncommon, and all of them did not need any additional treatment. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Case report on the non-operative management of a retrievable inferior vena cava filter perforating the duodenum.

    PubMed

    Fernandez-Moure, Joseph S; Kim, Keemberly; Zubair, M Haseeb; Rosenberg, Wade R

    2017-01-01

    Deep vein thrombosis (DVT) continues to be a significant source of morbidity for surgical patients. Placement of a retrievable inferior vena cava (IVC) filter is used when patients have contraindications to anticoagulation or recurrent pulmonary embolism despite therapeutic anticoagulation. Although retrievable IVC filters are often used, they carry a unique set of risks. A 67-year-old man presents to the Emergency Room (ER) following large volume melena and complaining of syncope. One year prior, the patient had been diagnosed with Glioblastoma multiforme, for which he underwent a craniotomy with near-total resection of the mass. He subsequently developed a deep vein thrombosis and underwent placement of a retrievable inferior vena cava (IVC) filter. Computerized tomography (CT) and esophagogastroduodenoscopy showed duodenal perforation by the retrievable IVC filter. The filter was successfully retrieved through an endovascular approach. Retrievable IVC filter placement is the preferred method of pulmonary embolism prevention in patients with significant risk for bleeding. Duodenal perforation by a retrievable IVC filter is a rare and serious complication. It is usually managed surgically, but can also be managed non-operatively. For patients with significant comorbidities or patients who are poor surgical candidates, non-operative management with close monitoring can serve as an initial approach to the patient with a caval enteric perforation secondary to a retrievable IVC filter. Copyright © 2017. Published by Elsevier Ltd.

  7. Evidence-Based Evaluation of Inferior Vena Cava Filter Complications Based on Filter Type

    PubMed Central

    Deso, Steven E.; Idakoji, Ibrahim A.; Kuo, William T.

    2016-01-01

    Many inferior vena cava (IVC) filter types, along with their specific risks and complications, are not recognized. The purpose of this study was to evaluate the various FDA-approved IVC filter types to determine device-specific risks, as a way to help identify patients who may benefit from ongoing follow-up versus prompt filter retrieval. An evidence-based electronic search (FDA Premarket Notification, MEDLINE, FDA MAUDE) was performed to identify all IVC filter types and device-specific complications from 1980 to 2014. Twenty-three IVC filter types (14 retrievable, 9 permanent) were identified. The devices were categorized as follows: conical (n = 14), conical with umbrella (n = 1), conical with cylindrical element (n = 2), biconical with cylindrical element (n = 2), helical (n = 1), spiral (n = 1), and complex (n = 1). Purely conical filters were associated with the highest reported risks of penetration (90–100%). Filters with cylindrical or umbrella elements were associated with the highest reported risk of IVC thrombosis (30–50%). Conical Bard filters were associated with the highest reported risks of fracture (40%). The various FDA-approved IVC filter types were evaluated for device-specific complications based on best current evidence. This information can be used to guide and optimize clinical management in patients with indwelling IVC filters. PMID:27247477

  8. A case of double inferior vena cava with renal, ovarian and iliac vein variation.

    PubMed

    Ito, Taro; Ikeda, Yayoi

    2018-01-01

    We encountered a rare case of an anatomic variant of inferior vena cava (IVC) duplication with renal, ovarian and iliac vein variation in an 81-year-old Japanese female cadaver during a student dissection course of anatomy at Aichi Gakuin University School of Dentistry. The two IVCs ran upwards bilaterally to the abdominal aorta. The left IVC joined with the left renal vein (RV) to form a common trunk that crossed anterior to the aorta and ended at the right IVC. We detected a vein [interiliac vein (IiV)] connecting the two IVCs at the level of the aortic bifurcation. The IiV was formed by the union of two tributaries from the left IVC and a tributary from the left internal iliac vein (IIV) and ran obliquely upwards from left to right. Two right ovarian veins, arising separately from the ipsilateral pampiniform plexus, ran vertically in parallel to each other, and each one independently terminated at the right IVC and the right RV. Two right IIVs, connecting each other with small branches, ascended and separately joined the right external iliac vein. The right and left IIVs were connected to each other. These variations cause abnormal drainage, which could lead to clinical symptoms associated with the dysfunction of the vascular and urogenital systems. Here we describe the detailed anatomical features of the area and discuss the related anatomical and developmental aspects.

  9. Safety and Efficacy of an Absorbable Filter in the Inferior Vena Cava to Prevent Pulmonary Embolism in Swine.

    PubMed

    Huang, Steven Y; Eggers, Mitchell; McArthur, Mark J; Dixon, Katherine A; McWatters, Amanda; Dria, Stephen; Hill, Lori R; Melancon, Marites P; Steele, Joseph R; Wallace, Michael J

    2017-12-01

    Purpose To evaluate the immediate and long-term safety as well as thrombus-capturing efficacy for 5 weeks after implantation of an absorbable inferior vena cava (IVC) filter in a swine model. Materials and Methods This study was approved by the institutional animal care and use committee. Eleven absorbable IVC filters made from polydioxanone suture were deployed via a catheter in the IVC of 11 swine. Filters remained in situ for 2 weeks (n = 2), 5 weeks (n = 2), 12 weeks (n = 2), 24 weeks (n = 2), and 32 weeks (n = 3). Autologous thrombus was administered from below the filter in seven swine from 0 to 35 days after filter placement. Fluoroscopy and computed tomography follow-up was performed after filter deployment from weeks 1-6 (weekly), weeks 7-20 (biweekly), and weeks 21-32 (monthly). The infrarenal IVC, lungs, heart, liver, kidneys, and spleen were harvested at necropsy. Continuous variables were evaluated with a Student t test. Results There was no evidence of IVC thrombosis, device migration, caval penetration, or pulmonary embolism. Gross pathologic analysis showed gradual device resorption until 32 weeks after deployment. Histologic assessment demonstrated neointimal hyperplasia around the IVC filter within 2 weeks after IVC filter deployment with residual microscopic fragments of polydioxanone suture within the caval wall at 32 weeks. Each iatrogenic-administered thrombus was successfully captured by the filter until resorbed (range, 1-4 weeks). Conclusion An absorbable IVC filter can be safely deployed in swine and resorbs gradually over the 32-week testing period. The device is effective for the prevention of pulmonary embolism for at least 5 weeks after placement in swine. © RSNA, 2017.

  10. The use of biological grafts for reconstruction of the inferior vena cava is a safe and valid alternative: results in 32 patients in a single institution

    PubMed Central

    Pulitanó, Carlo; Crawford, Michael; Ho, Phong; Gallagher, James; Joseph, David; Stephen, Michael; Sandroussi, Charbel

    2013-01-01

    Background Resection and reconstruction of the inferior vena cava (IVC) is occasionally required in the surgical treatment of intra-abdominal tumours. IVC reconstruction can be performed with biological or synthetic graft material, with most centres preferring synthetic grafts. In spite of the potential advantages of biological grafts in terms of handling characteristics, and safety, very limited data are available about their use in patients requiring an IVC resection. Methods Medical records of 32 patients who underwent an IVC resection and reconstruction from 1990 and 2011 with autogenous peritoneo-fascial (N = 22) and bovine pericardial (N = 10) grafts were reviewed. Results A tangential resection with patch repair was performed in 10 patients, whereas in the remaining 22 it was necessary to resect and replace a segment or all of the retrohepatic IVC. A concomitant liver resection was performed in 14 patients, nephrectomy in 10 and pancreaticoduodenectomy in 2 patients. There were no acute or late complications related to graft thrombosis or infection. Three patients died as a consequence of multi-organ failure. Overall survival at 1 and 5 years was 78% and 48%, respectively. Conclusions The preferential use of synthetic grafts in IVC replacement is not evidence based. Selection of an appropriate prosthetic graft for IVC reconstruction should be based on the safety and its handling features. The use of biological grafts for IVC repair is a valid alternative to current synthetic materials and may in fact be superior in terms of biocompatability, ease of handling, reduced rate of infection and improved long-term patency without permanent anticoagulation. PMID:23458108

  11. The use of biological grafts for reconstruction of the inferior vena cava is a safe and valid alternative: results in 32 patients in a single institution.

    PubMed

    Pulitanó, Carlo; Crawford, Michael; Ho, Phong; Gallagher, James; Joseph, David; Stephen, Michael; Sandroussi, Charbel

    2013-08-01

    Resection and reconstruction of the inferior vena cava (IVC) is occasionally required in the surgical treatment of intra-abdominal tumours. IVC reconstruction can be performed with biological or synthetic graft material, with most centres preferring synthetic grafts. In spite of the potential advantages of biological grafts in terms of handling characteristics, and safety, very limited data are available about their use in patients requiring an IVC resection. Medical records of 32 patients who underwent an IVC resection and reconstruction from 1990 and 2011 with autogenous peritoneo-fascial (N = 22) and bovine pericardial (N = 10) grafts were reviewed. A tangential resection with patch repair was performed in 10 patients, whereas in the remaining 22 it was necessary to resect and replace a segment or all of the retrohepatic IVC. A concomitant liver resection was performed in 14 patients, nephrectomy in 10 and pancreaticoduodenectomy in 2 patients. There were no acute or late complications related to graft thrombosis or infection. Three patients died as a consequence of multi-organ failure. Overall survival at 1 and 5 years was 78% and 48%, respectively. The preferential use of synthetic grafts in IVC replacement is not evidence based. Selection of an appropriate prosthetic graft for IVC reconstruction should be based on the safety and its handling features. The use of biological grafts for IVC repair is a valid alternative to current synthetic materials and may in fact be superior in terms of biocompatability, ease of handling, reduced rate of infection and improved long-term patency without permanent anticoagulation. © 2013 International Hepato-Pancreato-Biliary Association.

  12. The Value of Rotational Venography Versus Anterior–Posterior Venography in 100 Consecutive IVC Filter Retrievals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kiefer, Ryan M., E-mail: rkiefer11@gmail.com; Pandey, Nirnimesh; Trerotola, Scott O.

    PurposeAccurately detecting inferior vena cava (IVC) filter complications is important for safe and successful retrieval as tip-embedded filters require removal with non-standard techniques. Venography prior to IVC filter retrieval has traditionally used a single anterior–posterior (AP) projection. This study compares the utility of rotational venography to AP venography prior to IVC filter removal.Materials and MethodsThe rotational venograms from 100 consecutive IVC filter retrievals over a 35-month period were evaluated retrospectively. The AP view of the rotational venogram was examined separately from the full series by a radiologist blinded to alternative imaging and operative findings. The venograms were evaluated for tipmore » embedding, filter fracture, filter thrombus, and IVC thrombus. Statistical analysis was performed.ResultsUsing operative findings and peri-procedural imaging as the reference standard, tip embedding occurred in 59 of the 100 filters (59 %). AP venography was used to correctly identify 31 tip-embedded filters (53 % sensitivity) with two false positives (95 % specificity) for an accuracy of 70 %. Rotational venography was used to correctly identify 58 tip-embedded filters (98 % sensitivity) with one false positive (98 % specificity) for an accuracy of 98 %. A significant difference was found in the sensitivities of the two diagnostic approaches (P < .01). Other findings of thrombus and filter fracture were not significantly different between the two groups.ConclusionRotational venograms allow for more accurate detection of tip-embedded IVC filters compared to AP views alone. As this determines the approach taken, rotational venograms are helpful if obtained prior to IVC filter retrieval.« less

  13. Detection and characterization of Budd-Chiari syndrome with inferior vena cava obstruction: Comparison of fixed and flexible delayed scan time of computed tomography venography.

    PubMed

    Zhou, Peng-Li; Wu, Gang; Han, Xin-Wei; Bi, Yong-Hua; Zhang, Wen-Guang; Wu, Zheng-Yang

    2017-06-01

    To compare the results of computed tomography venography (CTV) with a fixed and a flexible delayed scan time for Budd-Chiari syndrome (BCS) with inferior vena cava (IVC) obstruction. A total of 209 consecutive BCS patients with IVC obstruction underwent either a CTV with a fixed delayed scan time of 180s (n=87) or a flexible delayed scan time for good image quality according to IVC blood flow in color Doppler ultrasonography (n=122). The IVC blood flow velocity was measured using a color Doppler ultrasound prior to CT scan. Image quality was classified as either good, moderate, or poor. Image quality, surrounding structures and the morphology of the IVC obstruction were compared between the two groups using a χ 2 -test or paired or unpaired t-tests as appropriate. Inter-observer agreement was assessed using Kappa statistics. There was no significant difference in IVC blood flow velocity between the two groups. Overall image quality, surrounding structures and IVC obstruction morphology delineation on the flexible delayed scan time of CTV images were rated better relative to those obtained by fixed delayed scan time of CTV images (p<0.001). Evaluation of CTV data sets was significantly facilitated with flexible delayed scan time of CTV. There were no significant differences in Kappa statistics between Group A and Group B. The flexible delayed scan time of CTV was associated with better detection and more reliable characterization of BCS with IVC obstruction compared to a fixed delayed scan time. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Prophylactic Placement of an Inferior Vena Cava Filter During Aspiration Thrombectomy for Acute Deep Venous Thrombosis of the Lower Extremity.

    PubMed

    Kwon, Se Hwan; Park, So Hyun; Oh, Joo Hyeong; Song, Myung Gyu; Seo, Tae-Seok

    2016-05-01

    To evaluate the effect of an inferior vena cava (IVC) filter during aspiration thrombectomy for acute deep vein thrombosis (DVT) in the lower extremity. From July 2004 to December 2013, a retrospective analysis of 106 patients with acute DVT was performed. All patients received an IVC filter and were treated initially with aspiration thrombectomy. Among the 106 patients, DVT extension into the IVC was noted in 27 but was not evident in 79. We evaluated the presence of trapped thrombi in the filters after the procedure. The sizes of the trapped thrombi were classified into 2 grades based on the ratio of the maximum transverse length of the trapped thrombus to the diameter of the IVC (Grades I [≤ 50%] and II [> 50%]). A trapped thrombus in the filter was detected in 46 (43%) of 106 patients on final venograms. The sizes of the trapped thrombi were grade I in 12 (26.1%) patients and grade II in 34 (73.9%). Among the 27 patients with DVT extension into the IVC, 20 (74.1%) showed a trapped thrombus in the filter, 75% (15 of 20) of which were grade II. Among the 79 patients without DVT extension into the IVC, 26 (32.9%) showed a trapped thrombus in the IVC filter, 73% (19 of 26) of which were grade II. Thrombus migration occurred frequently during aspiration thrombectomy of patients with acute DVT in the lower extremity. However, further studies are needed to establish a standard protocol for the prophylactic placement of an IVC filter during aspiration thrombectomy. © The Author(s) 2016.

  15. Improving inferior vena cava filter retrieval rates with the define, measure, analyze, improve, control methodology.

    PubMed

    Sutphin, Patrick D; Reis, Stephen P; McKune, Angie; Ravanzo, Maria; Kalva, Sanjeeva P; Pillai, Anil K

    2015-04-01

    To design a sustainable process to improve optional inferior vena cava (IVC) filter retrieval rates based on the Define, Measure, Analyze, Improve, Control (DMAIC) methodology of the Six Sigma process improvement paradigm. DMAIC, an acronym for Define, Measure, Analyze, Improve, and Control, was employed to design and implement a quality improvement project to increase IVC filter retrieval rates at a tertiary academic hospital. Retrievable IVC filters were placed in 139 patients over a 2-year period. The baseline IVC filter retrieval rate (n = 51) was reviewed through a retrospective analysis, and two strategies were devised to improve the filter retrieval rate: (a) mailing of letters to clinicians and patients for patients who had filters placed within 8 months of implementation of the project (n = 43) and (b) a prospective automated scheduling of a clinic visit at 4 weeks after filter placement for all new patients (n = 45). The effectiveness of these strategies was assessed by measuring the filter retrieval rates and estimated increase in revenue to interventional radiology. IVC filter retrieval rates increased from a baseline of 8% to 40% with the mailing of letters and to 52% with the automated scheduling of a clinic visit 4 weeks after IVC filter placement. The estimated revenue per 100 IVC filters placed increased from $2,249 to $10,518 with the mailing of letters and to $17,022 with the automated scheduling of a clinic visit. Using the DMAIC methodology, a simple and sustainable quality improvement intervention was devised that markedly improved IVC filter retrieval rates in eligible patients. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  16. 48-hours administration of fenoterol in spontaneous preterm labor - does it affect fetal preload?

    PubMed

    Grzesiak, Mariusz; Forys, Sebastian; Sobczak, Malgorzata; Ahmed, Rehana B; Wilczynski, Jan

    2013-01-01

    to investigate whether any changes in the preload index (PLI) occur within the first 48 hours of fenoterol intravenous tocolysis. Doppler evaluation of placental and fetal circulation was performed in 36 pregnant women prior to fenoterol administration and after 24/48 hours. Measurements were obtained from a longitudinal section of the inferior vena cava (IVC) and preload index was calculated. To determine changes over time, an all study variable analysis of variance (ANOVA) for repeated measurements, followed by Tukey-Kramer's multiple comparison test was used. The effects of additional clinical covariates were checked. The maternal heart rate values were significantly increased after 24 hours and 48 hours in comparison to pre-treatment values. No significant changes in fetal heart rate were observed during treatment. The fetal IVC PLI values were significantly reduced after 24 hours and 48 hours of treatment. The increase in PLI values when comparing 24 and 48 hours results were not statistically significant. These observations were consistent with ANOVA post-hoc analysis. 48 hours intravenous administration of fenoterol appears not to alter inferior vena cava blood flow by itself. The reduction in PLI values may reflect lower fetal preload conditions during the course of successful tocolytic treatment. Therefore, Doppler IVC PLI measurement should be considered as a possible additional assessment method of effectiveness of treatment. However, other Doppler venous blood flow parameters should be assessed to confirm the results and clarify whether maternal corticosteroids administration may be interfering with the results.

  17. It all unraveled from there: case report of a central venous catheter guidewire unraveling.

    PubMed

    Zerkle, Samuel; Emdadi, Vanessa; Mancinelli, Marc

    2014-12-01

    Inferior vena cava (IVC) filters can present challenges to emergency physicians in the process of central venous catheter (CVC) placement. A 68-year-old woman presented to the emergency department with severe shortness of breath and was intubated. A central line was placed after the intubation to facilitate peripheral access. A CVC guidewire unraveled during placement after getting caught on an IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians should be aware of the complications that IVC filters can cause in the placement of CVCs. Imaging and identification of IVC filters beforehand will allow for proper planning of how to manage the case in which a filter catches on the guidewire. Simple anecdotal techniques, such as advancing the guidewire and spinning the guidewire between the fingers, can facilitate the removal of the guide wire from the IVC filter. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Use of a Trellis Device for Endovascular Treatment of Venous Thrombosis Involving a Duplicated Inferior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saettele, Megan R., E-mail: SaetteleM@umkc.edu; Morelli, John N., E-mail: dr.john.morelli@gmail.com; Chesis, Paul

    Congenital anomalies of the inferior vena cava (IVC) are increasingly recognized with CT and venography techniques. Although many patients with IVC anomalies are asymptomatic, recent studies have suggested an association with venous thromboembolism. We report the case of a 62-year-old woman with extensive venous clot involving the infrarenal segment of a duplicated left IVC who underwent pharmacomechanical thrombectomy and tissue plasminogen activator catheter-directed thrombolysis with complete deep venous thrombosis resolution. To our knowledge this is the first reported case in the English literature of the use of a Trellis thrombectomy catheter in the setting of duplicated IVC.

  19. Focal Atrial Tachycardia Arising from the Inferior Vena Cava

    PubMed Central

    Lim, Yeong-Min; Uhm, Jae-Sun

    2017-01-01

    The inferior vena cava (IVC) is a rare site of focal atrial tachycardia (AT). Here, we report a 20-year-old woman who underwent catheter ablation for anti-arrhythmic drug-resistant AT originating from the IVC. She had undergone open-heart surgery for patch closure of an atrial septal defect 17 years previously and permanent pacemaker implantation for sinus node dysfunction 6 years previously. The AT focus was at the anterolateral aspect of the IVC-right atrial junction, and it was successfully ablated under three-dimensional electroanatomical-mapping guidance. We suspect that the mechanism of this tachycardia was associated with previous IVC cannulation for open-heart surgery. PMID:28541006

  20. Inferior Vena Cava Filters: Guidelines, Best Practice, and Expanding Indications

    PubMed Central

    DeYoung, Elliot; Minocha, Jeet

    2016-01-01

    Vena caval interruption, currently accomplished by percutaneous image-guided insertion of an inferior vena cava (IVC) filter, is an important therapeutic option in the management of selected patients with venous thromboembolism. The availability of optional (or retrievable) filters, in particular, has altered the practice patterns for IVC filters, with a shift to these devices and expansion of indications for filter placement. As new devices have become available and clinicians have become more familiar and comfortable with IVC filters, the indications for filter placement have continued to evolve and expand. This article reviews current guidelines and expanding indications for IVC filter placement. PMID:27247472

  1. A case of left inferior vena cava.

    PubMed

    Yano, R; Hayakawa, D; Emura, S; Chen, H; Ozawa, Y; Taguchi, H; Shoumura, S

    2001-12-01

    A case of left inferior vena cava (IVC) was found in a 72-year-old male cadaver during student dissection practice in 1999 at Gifu University School of Medicine. It was formed by junction of the left and right common iliac veins at the lower left corner of the 5th lumbar vertebra. This IVC (15-mm caliber) ascended 82 mm along the left side of the abdominal aorta dorsally to the ureter. Receiving the left renal vein, it became 21 mm in caliber and ran obliquely upward for 43 mm across the abdominal aorta. As soon as it received two right renal veins at the level of the 2nd lumbar vertebra, the IVC (25-mm caliber) turned directly above. The present case belongs to Type C of the classification of McClure and Butler (1925), which is based on the combinations of the left and right IVCs, and on their location relative to the ureters. The present case also belongs to Type 1 of the classification of Yoshida et al. (1981). We consider that left IVC in the present case is mainly caused by disappearance of the right supracardinal vein and persistence of the left one during the embryological development of the IVC.

  2. Left-sided and duplicate inferior vena cava: a case series and review.

    PubMed

    Ang, Wee Choen; Doyle, Terry; Stringer, Mark D

    2013-11-01

    Left-sided and duplicate inferior vena cava (IVC) are two major anatomical variants within the spectrum of IVC malformations, both of which are developmental abnormalities of the supracardinal veins. Four clinical cases are described to highlight the computed tomographic appearances of these vascular malformations and provide novel data on venous dimensions. A systematic review of the recent literature (2000-2011) was conducted focusing on the anatomy, demographics, and associated pathology (congenital and acquired) of isolated left-sided and duplicate IVC. A total of 73 relevant articles were retrieved, consisting of case reports and small case series. The prevalence of left-sided IVC is about 0.1-0.4% and that for duplicate IVC about 0.3-0.4%; both anomalies show a slight male preponderance. In each condition, there are documented variations in the course and tributaries of the IVC. The clinical importance of these anomalies lies in three principal areas: the potential for misdiagnosis on imaging; technical difficulties during retroperitoneal surgery (particularly abdominal aortic aneurysm repair and live donor nephrectomy); and their significance in relation to the etiology and management of venous thromboembolism. Copyright © 2012 Wiley Periodicals, Inc.

  3. Proposal for a new classification of variations in the iliac venous system based on internal iliac veins: a case series and a review of double and left inferior vena cava.

    PubMed

    Hayashi, Shogo; Naito, Munekazu; Hirai, Shuichi; Terayama, Hayato; Miyaki, Takayoshi; Itoh, Masahiro; Fukuzawa, Yoshitaka; Nakano, Takashi

    2013-09-01

    There are many reports on variations in the inferior vena cava (IVC), particularly double IVC (DIVC) and left IVC (LIVC). However, no systematic report has recorded iliac vein (IV) flow patterns in the DIVC and LIVC. In this study, we examined IV flow patterns in both DIVC and LIVC observed during gross anatomy courses conducted for medical students and in previously reported cases. During the gross anatomy courses, three cases of DIVC and one case of LIVC were found in 618 cadavers. The IV flow pattern from these four cases and all other previously reported cases can be classified into one of the following three types according to the vein into which the internal iliac vein drained: the ipsilateral external IV; confluence of the ipsilateral external IV and IVC; and the communicating vein, which connects the IVC and the contralateral IVC or its iliac branch. This classification, which is based on the internal IV course, is considered to be useful because IV variations have the potential to cause clinical problems during related retroperitoneal surgery, venous interventional radiology, and diagnostic procedures for pelvic cancer.

  4. Circulating Tumor DNA in Predicting Outcomes in Patients With Stage IV Head and Neck Cancer or Stage III-IV Non-small Cell Lung Cancer

    ClinicalTrials.gov

    2018-01-12

    Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Salivary Gland Squamous Cell Carcinoma; Stage IIIA Non-small Cell Lung Cancer; Stage IIIB Non-small Cell Lung Cancer; Stage IV Non-small Cell Lung Cancer; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer; Untreated Metastatic Squamous Neck Cancer With Occult Primary

  5. Temsirolimus With or Without Cetuximab in Patients With Recurrent and/or Metastatic Head and Neck Cancer Who Did Not Respond to Previous Therapy

    ClinicalTrials.gov

    2017-02-23

    Recurrent Hypopharyngeal Squamous Cell Carcinoma; Recurrent Laryngeal Squamous Cell Carcinoma; Recurrent Laryngeal Verrucous Carcinoma; Recurrent Lip and Oral Cavity Squamous Cell Carcinoma; Recurrent Metastatic Squamous Cell Carcinoma in the Neck With Occult Primary; Recurrent Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Recurrent Nasopharyngeal Keratinizing Squamous Cell Carcinoma; Recurrent Oral Cavity Verrucous Carcinoma; Recurrent Oropharyngeal Squamous Cell Carcinoma; Recurrent Salivary Gland Carcinoma; Salivary Gland Squamous Cell Carcinoma; Squamous Cell Carcinoma Metastatic in the Neck With Occult Primary; Stage IV Hypopharyngeal Squamous Cell Carcinoma; Stage IV Nasopharyngeal Keratinizing Squamous Cell Carcinoma; Stage IVA Laryngeal Squamous Cell Carcinoma; Stage IVA Laryngeal Verrucous Carcinoma; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVA Major Salivary Gland Carcinoma; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVA Oral Cavity Verrucous Carcinoma; Stage IVA Oropharyngeal Squamous Cell Carcinoma; Stage IVB Laryngeal Squamous Cell Carcinoma; Stage IVB Laryngeal Verrucous Carcinoma; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVB Major Salivary Gland Carcinoma; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVB Oral Cavity Verrucous Carcinoma; Stage IVB Oropharyngeal Squamous Cell Carcinoma; Stage IVC Laryngeal Squamous Cell Carcinoma; Stage IVC Laryngeal Verrucous Carcinoma; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVC Major Salivary Gland Carcinoma; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVC Oral Cavity Verrucous Carcinoma; Stage IVC Oropharyngeal Squamous Cell Carcinoma; Tongue Carcinoma

  6. Oncological outcomes after cytoreductive nephrectomy for patients with metastatic renal cell carcinoma with inferior vena caval tumor thrombus.

    PubMed

    Miyake, Hideaki; Sugiyama, Takayuki; Aki, Ryota; Matsushita, Yuto; Tamura, Keita; Motoyama, Daisuke; Ito, Toshiki; Otsuka, Atsushi

    2018-06-01

    To evaluate the oncological outcomes of patients with metastatic renal cell carcinoma (mRCC) involving the inferior vena cava (IVC) who received cytoreductive nephrectomy. This study included 75 consecutive metastatis renal cell carcinoma (mRCC) patients with inferior vena cava (IVC) tumor thrombus undergoing cytoreductive nephrectomy and tumor thrombectomy followed by systemic therapy. Of the 75 patients, 11, 33, 24 and 7 had level I, II, III and IV IVC thrombus, respectively. Following surgical treatment, 25 (group A), 27 (group B) and 23 (group C) received cytokine therapy alone, molecular-targeted therapy alone and both therapies, respectively, as management for metastatic diseases. The median overall survival (OS) of the 75 patients was 16.2 months. No significant differences in OS were noted according to the level of the IVC tumor thrombus. There were no significant differences in OS among groups A, B and C; however, OS in groups B and C was significantly superior to that in group A. Furthermore, multivariate analysis of several parameters identified the following independent predictors of poor OS-elevated C-reactive protein, liver metastasis and postoperative treatment with cytokine therapy alone. The prognosis of mRCC patients with IVC thrombus undergoing cytoreductive nephrectomy may be significantly affected by the type of postoperative systemic therapy rather than the level of the IVC tumor thrombus. Accordingly, cytoreductive nephrectomy should be considered as a major therapeutic option for patients with mRCC involving the IVC, particularly in the era of targeted therapy.

  7. Procedural and Indwelling Complications with Inferior Vena Cava Filters: Frequency, Etiology, and Management

    PubMed Central

    Milovanovic, Lazar; Kennedy, Sean A.; Midia, Mehran

    2015-01-01

    Inferior vena cava (IVC) filters are commonly used in select high-risk patients for the prevention of pulmonary embolism. Potentially serious complications can arise from the use of IVC filters, including thrombosis of the filter itself and filter fragment embolization. This article discusses the utility of IVC filters and reviews the management of two cases of filter-related complications. PMID:25762846

  8. Fontan completion in patients with atrial isomerism and separate hepatic venous drainage.

    PubMed

    Nakata, Tomohiro; Fujimoto, Yoshifumi; Hirose, Keiichi; Osaki, Masaki; Tosaka, Yuko; Ide, Yujiro; Tachi, Maiko; Sakamoto, Kisaburo

    2010-06-01

    Fontan completion in patients with atrial isomerism, in which the inferior vena cava (IVC) and the hepatic vein (HV) drain separately, is technically challenging. Herein, we review our surgical approach to these patients. The medical records of 50 consecutive patients with atrial isomerism who underwent Fontan completion between 1998 and 2008 were reviewed retrospectively. Separate HV drainage was present in 17 patients. Patients with interrupted IVC were excluded. Patient characteristics were as follows: median age, 26 months (range 15-149); median weight, 9.6 kg (range 8.1-47.2); right atrial isomerism, 16 patients; and left atrial isomerism, one. The IVC and the separate HV at the level of diaphragm were contralateral in 16 patients, and ipsilateral in one. The surgical procedures for directing blood flow from the IVC and the separate HV to the pulmonary arteries were as follows: en bloc resection of the IVC and the HV and anastomosing these veins to an extracardiac conduit in 10 patients; connecting the IVC to the HV in a side-to-side fashion before anastomosing them to an extracardiac conduit in one; and lateral tunnel in another. When the IVC and the HV were widely separated by the vertebrae, we chose an intra-extracardiac conduit (intra-atrial septation) in four patients and an extracardiac conduit for the IVC and the right HV and lateral tunnel for the separate left HV in one. There was no mortality. Five re-operations were performed (pacemaker in two patients; one each of fenestration, release of outflow obstruction and ligation of collateral arteries). Sixteen patients underwent follow-up catheterisation, which revealed central venous pressure of 12.0 + or - 2.0 mmHg and arterial oxygen saturation of 92% + or - 6%. The mid-term results of the Fontan completion in patients with atrial isomerism and separate HV drainage were excellent. The distance between the IVC and the separate HV and the position of the vertebrae should be considered when choosing a surgical technique. Copyright 2010. Published by Elsevier B.V.

  9. Comparing blastocyst quality and live birth rates of intravaginal culture using INVOcell™ to traditional in vitro incubation in a randomized open-label prospective controlled trial.

    PubMed

    Doody, Kevin J; Broome, E Jason; Doody, Kathleen M

    2016-04-01

    The purpose of this study is to to compare the efficacy of intravaginal culture (IVC) of embryos in INVOcell™ (INVO Bioscience, MA, USA) to traditional in vitro fertilization (IVF) incubators in a laboratory setting using a mild pre-determined stimulation regimen based solely on anti-mullerian hormone (AMH) and body weight with minimal ultrasound monitoring. The primary endpoint examined was total quality blastocysts expressed as a percentage of total oocytes placed in incubation. Secondary endpoints included percentage of quality blastocysts transferred, pregnancy, and live birth rates. In this prospective randomized open-label controlled single-center study, 40 women aged <38 years of age with a body mass index (BMI) of <36 and an AMH of 1-3 ng/mL were randomized prior to trigger to receive either IVC or IVF. Controlled ovarian stimulation was administered with human menopausal gonadotropin (hMG) in a fixed gonadotropin-releasing hormone (GnRH) agonist cycle based solely on AMH and body weight. A single ultrasound-monitoring visit was performed on the 10th day of stimulation. One or two embryos were transferred following 5 days of culture. IVF produced a greater percentage of total quality embryos as compared to IVC (50.6 vs. 30.7 %, p = 0.0007, respectively). There was no significant difference between in IVF and IVC in the percentage of quality blastocysts transferred (97.5 vs. 84.9 %, p = 0.09) or live birth rate (60 % IVF, 55 % IVC). IVF was shown to be superior to IVC in creating quality blastocysts. However, both IVF and IVC produced identical blastocysts for transfer resulting in similar live birth rates. IVC using INVOcell™ is effective and may broaden access to fertility care in selected patient populations by ameliorating the need for a traditional IVF laboratory setting. Further studies will help elucidate the potential physiological, psychological, geographic, and financial impact of IVC on the delivery of fertility care.

  10. Predicting preload responsiveness using simultaneous recordings of inferior and superior vena cavae diameters.

    PubMed

    Charbonneau, Hélène; Riu, Béatrice; Faron, Matthieu; Mari, Arnaud; Kurrek, Matt M; Ruiz, Jean; Geeraerts, Thomas; Fourcade, Olivier; Genestal, Michèle; Silva, Stein

    2014-09-05

    Echocardiographic indices based on respiratory variations of superior and inferior vena cavae diameters (ΔSVC and ΔIVC, respectively) have been proposed as predictors of fluid responsiveness in mechanically ventilated patients, but they have never been compared simultaneously in the same patient sample. The aim of this study was to compare the predictive value of these echocardiographic indices when concomitantly recorded in mechanically ventilated septic patients. Septic shock patients requiring hemodynamic monitoring were prospectively enrolled over a 1-year period in a mixed medical surgical ICU of a university teaching hospital (Toulouse, France). All patients were mechanically ventilated. Predictive indices were obtained by transesophageal and transthoracic echocardiography and were calculated as follows: (Dmax - Dmin)/Dmax for ΔSVC and (Dmax - Dmin)/Dmin for ΔIVC, where Dmax and Dmin are the maximal and minimal diameters of SVC and IVC. Measurements were performed at baseline and after a 7-ml/kg volume expansion using a plasma expander. Patients were separated into responders (increase in cardiac index ≥15%) and nonresponders (increase in cardiac index <15%). Among 44 included patients, 26 (59%) patients were responders (R). ΔSVC was significantly more accurate than ΔIVC in predicting fluid responsiveness. The areas under the receiver operating characteristic curves for ΔSVC and ΔIVC regarding assessment of fluid responsiveness were significantly different (0.74 (95% confidence interval (CI): 0.59 to 0.88) and 0.43 (95% CI: 0.25 to 0.61), respectively (P = 0.012)). No significant correlation between ΔSVC and ΔIVC was found (r = 0.005, P = 0.98). The best threshold values for discriminating R from NR was 29% for ΔSVC, with 54% sensitivity and 89% specificity, and 21% for ΔIVC, with 38% sensitivity and 61% specificity. ΔSVC was better than ΔIVC in predicting fluid responsiveness in our cohort. It is worth noting that the sensitivity and specificity values of ΔSVC and ΔIVC for predicting fluid responsiveness were lower than those reported in the literature, highlighting the limits of using these indices in a heterogeneous sample of medical and surgical septic patients.

  11. Performance evaluation of MPEG internet video coding

    NASA Astrophysics Data System (ADS)

    Luo, Jiajia; Wang, Ronggang; Fan, Kui; Wang, Zhenyu; Li, Ge; Wang, Wenmin

    2016-09-01

    Internet Video Coding (IVC) has been developed in MPEG by combining well-known existing technology elements and new coding tools with royalty-free declarations. In June 2015, IVC project was approved as ISO/IEC 14496-33 (MPEG- 4 Internet Video Coding). It is believed that this standard can be highly beneficial for video services in the Internet domain. This paper evaluates the objective and subjective performances of IVC by comparing it against Web Video Coding (WVC), Video Coding for Browsers (VCB) and AVC High Profile. Experimental results show that IVC's compression performance is approximately equal to that of the AVC High Profile for typical operational settings, both for streaming and low-delay applications, and is better than WVC and VCB.

  12. Are too many inferior vena cava filters used? Controversial evidences in different clinical settings: a narrative review.

    PubMed

    Dalla Vestra, Michele; Grolla, Elisabetta; Bonanni, Luca; Pesavento, Raffaele

    2018-03-01

    The use of inferior vena cava filters to prevent pulmonary embolism is increasing mainly because of indications that appear to be unclearly codified and recommended. The evidence supporting this approach is often heterogeneous, and mainly based on observational studies and consensus opinions, while the insertion of an IVC filter exposes patients to the risk of complications and increases health care costs. Thus, several proposed indications for an IVC filter placement remain controversial. We attempt to review the proof on the efficacy and safety of IVC filters in several "special" clinical settings, and assess the robustness of the available evidence for any specific indication to place an IVC filter.

  13. Cisplatin With or Without WEE1 Inhibitor MK-1775 in Treating Patients With Recurrent or Metastatic Head and Neck Cancer

    ClinicalTrials.gov

    2017-03-22

    Recurrent Hypopharyngeal Squamous Cell Carcinoma; Recurrent Laryngeal Squamous Cell Carcinoma; Recurrent Laryngeal Verrucous Carcinoma; Recurrent Lip and Oral Cavity Squamous Cell Carcinoma; Recurrent Metastatic Squamous Cell Carcinoma in the Neck With Occult Primary; Recurrent Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Recurrent Oral Cavity Verrucous Carcinoma; Recurrent Oropharyngeal Squamous Cell Carcinoma; Squamous Cell Carcinoma Metastatic in the Neck With Occult Primary; Stage IV Hypopharyngeal Squamous Cell Carcinoma; Stage IVA Laryngeal Squamous Cell Carcinoma; Stage IVA Laryngeal Verrucous Carcinoma; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVA Oral Cavity Verrucous Carcinoma; Stage IVA Oropharyngeal Squamous Cell Carcinoma; Stage IVB Laryngeal Squamous Cell Carcinoma; Stage IVB Laryngeal Verrucous Carcinoma; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVB Oral Cavity Verrucous Carcinoma; Stage IVB Oropharyngeal Squamous Cell Carcinoma; Stage IVC Laryngeal Squamous Cell Carcinoma; Stage IVC Laryngeal Verrucous Carcinoma; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVC Oral Cavity Verrucous Carcinoma; Stage IVC Oropharyngeal Squamous Cell Carcinoma; Tongue Carcinoma

  14. Temporary Inferior Vena Cava Filters: How Do We Move Forward?

    PubMed

    Arous, Edward J; Messina, Louis M

    2016-05-01

    Despite their widespread use, the indications for the selective use of temporary inferior vena cava (IVC) filters remains uncertain with few trials supporting their use. Additionally, the risks of long-term temporary IVC filter insertion are being increasingly discussed amongst the mainstream media and through multiple class action lawsuits. Retrievable IVC filters were specifically designed to have a less secure implantation in order to facilitate retrieval. However, multiple reports have demonstrated significant filter-related complications, most commonly related to duration of implantation. Furthermore, the risk is not isolated to one manufacturer alone. The incidence of filter-related complications is linearly related to its duration of time on the market. Currently, the FDA recommends that IVC filters be removed within 25-54 days of their implantation. Unfortunately, little evidence exists to show that this recommendation is followed routinely. Recently, the PRESERVE Trial (NCT02381509) was initiated as a multicenter non-randomized open label study to determine the safety and effectiveness of commercially available IVC filters (both temporary and permanent) in individuals who require mechanical prophylaxis against pulmonary embolism. Until such evidence is developed, temporary IVC filters should be implanted based on best available evidence and routinely removed within the guidelines of the FDA of 25-54 days. A fair question at this point is whether the design features themselves that are required to manufacture a low profile removable IVC filter can achieve effective prophylaxis against pulmonary embolism at a low rate of short and long-term complications. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  15. Comparison of retrievable stents and permanent stents for Budd-Chiari syndrome due to obstructive inferior vena cava.

    PubMed

    Bi, Yonghua; Chen, Hongmei; Ding, Penxu; Ren, Jianzhuang; Han, Xinwei

    2018-05-30

    To compare long-term outcomes of retrievable stents and permanent stents for BCS due to long-segment obstructive IVC. Between July 2000 and August 2016, 42 patients with BCS due to long-segment obstructive IVC were treated with retrievable stents (RS) and 41 patients were treated with permanent stents (PS). The retrievable stents was removed eventually after thrombus disappeared. Patients were subsequently followed-up by color Doppler sonography or CT scanning. All retrievable stent placements were successfully, and 37 retrievable stents were retrieved 8 to 29 days later. Forty-two stents were implanted in PS Group. One failure retrieval of retrievable stents occurred, and two failures of cannulations were found in PS Group. Two deaths may procedure-related and died from acute pulmonary thromboembolism perioperatively. One patient developed acute cerebral infarction and recovered after treatment. In PS Group, minor complications were found in 3 patients. The length of IVC lesion segment, length and thickness of IVC thrombus decreased significantly, and diameter of retrocaval IVC and diaphragm IVC increased significantly in both groups. During follow up, 3 patients died from liver failure in RS Group and 2 patients died in PS Group. RS Group showed a significantly higher primary patency rate than PS Group. Cumulative 1-, 3-, and 5-year secondary patency rates were 95.2%, 89.6%, 89.6% in RS Group, and 100%, 96.6%, 96.6% in PS Group (p= 0.7109). Retrievable stents is effective for BCS due to long-segment obstructive IVC, with a higher primary patency rate. This article is protected by copyright. All rights reserved.

  16. Ultrasound assessment of severe dehydration in children with diarrhea and vomiting.

    PubMed

    Levine, Adam C; Shah, Sachita P; Umulisa, Irenee; Munyaneza, Richard B Mark; Dushimiyimana, Jean Marie; Stegmann, Katrina; Musavuli, Juvenal; Ngabitsinze, Protogene; Stulac, Sara; Epino, Henry M; Noble, Vicki E

    2010-10-01

    The objective of this study was to determine the test characteristics for two different ultrasound (US) measures of severe dehydration in children (aorta to inferior vena cava [IVC] ratio and IVC inspiratory collapse) and one clinical measure of severe dehydration (the World Health Organization [WHO] dehydration scale). The authors enrolled a prospective cohort of children presenting with diarrhea and/or vomiting to three rural Rwandan hospitals. Children were assessed clinically using the WHO scale and then underwent US of the IVC by a second clinician. All children were weighed on admission and then fluid-resuscitated according to standard hospital protocols. A percent weight change between admission and discharge of greater than 10% was considered the criterion standard for severe dehydration. Receiver operating characteristic (ROC) curves were created for each of the three tests of severe dehydration compared to the criterion standard. Children ranged in age from 1 month to 10 years; 29% of the children had severe dehydration according to the criterion standard. Of the three different measures of dehydration tested, only US assessment of the aorta/IVC ratio had an area under the ROC curve statistically different from the reference line. At its best cut-point, the aorta/IVC ratio had a sensitivity of 93% and specificity of 59%, compared with 93% and 35% for IVC inspiratory collapse and 73% and 43% for the WHO scale. Ultrasound of the aorta/IVC ratio can be used to identify severe dehydration in children presenting with acute diarrhea and may be helpful in guiding clinical management. © 2010 by the Society for Academic Emergency Medicine.

  17. Impact of Anticoagulation in Elderly Patients With Pulmonary Embolism That Undergo IVC Filter Placement: A Retrospective Cohort Study.

    PubMed

    Falatko, John M; Dalal, Bhavinkumar; Qu, Lihua

    2017-12-01

    Anticoagulation is the primary treatment for pulmonary embolism (PE). Inferior vena cava (IVC) filters are an adjunctive intervention to prevent recurrent pulmonary embolism. Long-term outcomes in elderly patients with contraindications to anticoagulation after IVC filter placement for prevention of recurrent pulmonary embolism have yet to be assessed. Patients ≥60years of age, that had an IVC filter placed between 1 January, 2008 and 2 February, 2013, with a primary diagnosis of pulmonary embolism, were included. Patients that died during index hospitalisation, were discharged to hospice, or had active malignancy were excluded. The primary endpoint was overall survival. Patients were divided depending on whether they were treated with an approved anticoagulant for VTE or had no anticoagulant. Of the 152 patients identified, 55 were not anti-coagulated after IVC filter placement. The incidence of death was 0.4 per 1000 filter days and 0.7 per 1000 filter days in the anti-coagulated and untreated groups respectively (p-value=0.06). After statistical correction for co-morbid conditions, the effect of anticoagulation was not significant (HR 0.82 CI 0.49-1.37, p-value 0.46). Age was a significant confounder that was associated with death. Increased BMI was protective. Indications for IVC filter placement were numerous, but similar between the two groups. Treatment with an approved anticoagulant is recommended after IVC filter placement for prevention of recurrent PE, however its effect may be attenuated by advanced age. In elderly patients that have undergone IVC filter placement for prevention of recurrent PE, survival may be more dependent on age and co-morbid conditions than exposure to anticoagulation. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  18. Risks and benefits of prophylactic inferior vena cava filters in patients undergoing bariatric surgery.

    PubMed

    Birkmeyer, Nancy J; Finks, Jonathan F; English, Wayne J; Carlin, Arthur M; Hawasli, Abdelkader A; Genaw, Jeffrey A; Wood, Michael H; Share, David A; Birkmeyer, John D

    2013-04-01

    The United States Food and Drug Administration recently issued a warning about adverse events in patients receiving inferior vena cava (IVC) filters. To assess relationships between IVC filter insertion and complications while controlling for differences in baseline patient characteristics and medical venous thromboembolism prophylaxis. Propensity-matched cohort study. The prospective, statewide, clinical registry of the Michigan Bariatric Surgery Collaborative. Bariatric surgery patients (n=35,477) from 32 hospitals during the years 2006 through 2012. Prophylactic IVC filter insertion. Outcomes included the occurrence of complications (pulmonary embolism, deep vein thrombosis, and overall combined rates of complications by severity) within 30 days of bariatric surgery. There were no significant differences in baseline characteristics among the 1,077 patients with IVC filters and in 1,077 matched control patients. Patients receiving IVC filters had higher rates of pulmonary embolism (0.84% vs 0.46%; odds ratio [OR], 2.0; 95% confidence interval [CI], 0.6-6.5; P=0.232), deep vein thrombosis (1.2% vs 0.37%; OR, 3.3; 95% CI, 1.1-10.1; P=0.039), venous thromboembolism (1.9% vs 0.74%; OR, 2.7; 95% CI, 1.1-6.3, P=0.027), serious complications (5.8% vs 3.8%; OR, 1.6; 95% CI, 1.0-2.4; P=0.031), permanently disabling complications (1.2% vs 0.37%; OR, 4.3; 95% CI, 1.2-15.6; P=0.028), and death (0.7% vs 0.09%; OR, 7.0; 95% CI, 0.9-57.3; P=0.068). Of the 7 deaths among patients with IVC filters, 4 were attributable to pulmonary embolism and 2 to IVC thrombosis/occlusion. We have identified no benefits and significant risks to the use of prophylactic IVC filters among bariatric surgery patients and believe that their use should be discouraged. Copyright © 2013 Society of Hospital Medicine.

  19. Prevalence of human papillomavirus types in invasive vulvar cancers and vulvar intraepithelial neoplasia 3 in the United States before vaccine introduction.

    PubMed

    Gargano, Julia W; Wilkinson, Edward J; Unger, Elizabeth R; Steinau, Martin; Watson, Meg; Huang, Youjie; Copeland, Glenn; Cozen, Wendy; Goodman, Marc T; Hopenhayn, Claudia; Lynch, Charles F; Hernandez, Brenda Y; Peters, Edward S; Saber, Maria Sibug; Lyu, Christopher W; Sands, Lauren A; Saraiya, Mona

    2012-10-01

    The study aimed to determine the baseline prevalence of human papillomavirus (HPV) types in invasive vulvar cancer (IVC) and vulvar intraepithelial neoplasia 3 (VIN 3) cases using data from 7 US cancer registries. Registries identified eligible cases diagnosed in 1994 to 2005 and requested pathology laboratories to prepare 1 representative block for HPV testing on those selected. Hematoxylin-eosin-stained sections preceding and following those used for extraction were reviewed to confirm representation. Human papillomavirus was detected using L1 consensus polymerase chain reaction (PCR) with PGMY9/11 primers and type-specific hybridization, with retesting of samples with negative and inadequate results with SPF10 primers. For IVC, the confirmatory hematoxylin-eosin slides were re-evaluated to determine histological type. Descriptive analyses were performed to examine distributions of HPV by histology and other factors. Human papillomavirus was detected in 121/176 (68.8%) cases of IVC and 66/68 (97.1%) cases of VIN 3 (p < .0001). Patients with IVC and VIN 3 differed by median age (70 vs 55 y, p = .003). Human papillomavirus 16 was present in 48.6% of IVC cases and 80.9% of VIN 3 cases; other high-risk HPV was present in 19.2% of IVC cases and 13.2% of VIN 3 cases. Prevalence of HPV differed by squamous cell carcinoma histological subtype (p < .0001) as follows: keratinizing, 49.1% (n = 55); nonkeratinizing, 85.7% (n = 14), basaloid, 92.3% (n = 14), warty 78.2% (n = 55), and mixed warty/basaloid, 100% (n = 7). Nearly all cases of VIN 3 and two thirds of IVC cases were positive for high-risk HPV. Prevalence of HPV ranged from 49.1% to 100% across squamous cell carcinoma histological subtypes. Given the high prevalence of HPV in IVC and VIN 3 cases, prophylactic vaccines have the potential to decrease the incidence of vulvar neoplasia.

  20. Virulence of viral hemorrhagic septicemia virus (VHSV) genotypes Ia, IVa, IVb, and IVc in five fish species.

    USGS Publications Warehouse

    Emmenegger, Eveline J.; Moon, Chang Hoon; Hershberger, Paul K.; Kurath, Gael

    2013-01-01

    The susceptibility of yellow perch Perca flavescens, rainbow trout Oncorhynchus mykiss, Chinook salmon O. tshawytscha, koi Cyprinus carpio koi, and Pacific herring Clupea pallasii to 4 strains of viral hemorrhagic septicemia virus (VHSV) was assessed. Fish were challenged via intraperitoneal injection with high (1 × 106 plaque-forming units, PFU) and low (1 × 103 PFU) doses of a European strain (genotype Ia), and North American strains from the West coast (genotype IVa), Great Lakes (genotype IVb), and the East coast (genotype IVc). Pacific herring were exposed to the same VHSV strains, but at a single dose of 5 × 103 PFU ml-1 by immersion in static seawater. Overall, yellow perch were the most susceptible, with cumulative percent mortality (CPM) ranging from 84 to 100%, and 30 to 93% in fish injected with high or low doses of virus, respectively. Rainbow trout and Chinook salmon experienced higher mortalities (47 to 98% CPM) after exposure to strain Ia than to the other virus genotypes. Pacific herring were most susceptible to strain IVa with an average CPM of 80% and moderately susceptible (42 to 52% CPM) to the other genotypes. Koi had very low susceptibility (≤5.0% CPM) to all 4 VHSV strains. Fish tested at 7 d post challenge were positive for all virus strains, with yellow perch having the highest prevalence and concentrations of virus, and koi the lowest. While genotype Ia had higher virulence in salmonid species, there was little difference in virulence or host-specificity between isolates from subtypes IVa, IVb, and IVc.  

  1. Transcatheter Arterial Chemoembolization for Advanced Hepatocellular Carcinoma with Inferior Vena Cava and Right Atrial Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chern, M. C., E-mail: mcchern@yahoo.com; Chuang, V. P., E-mail: vpc@mail.kfcc.org.tw; Cheng, T., E-mail: ticheng@mail.kfcc.org.tw

    Advanced hepatocelluar carcinoma (HCC) with invasion of venous systems usually indicates not only a poor prognosis but also a contraindication for transcatheter arterial chemoembolization (TACE). This study evaluated the feasibility of TACE for advanced HCC with inferior vena cava (IVC) and right atrium (RA) tumors and, also, to search for the ideal embolization particle size. Twenty-six patients who had HCC invasion into the IVC included five patients with coexistent RA tumors that were treated with TACE. The chemoembolization method was cisplatin, doxorubicin, and mitomycin C mixed with Lipiodol and Ivalon. The selection of Ivalon particles was divided into two groupsmore » based on their size: (A) >180 {mu}m, N = 9; and (B) 47-180 {mu}m, N = 17. The overall response rate was 53.8% (14/26). Based on the response to TACE, the median survival period of the entire group was 4.2 months (range, 1.5 to 76.7 months). The median survival period of the 14 responders was 13.5 months (1.5-76.7 months), and that of the 12 nonresponders, 3.3 months (2.1 to 24.3 months) (p < 0.002). Comparing the two Ivalon particle sizes, the response rate was 12.5% (1/9 patients) for group A and 76.5% for group B (13/17 patients) (p < 0.02). No serious complication was observed post-chemoembolization. In conclusion, TACE is a safe and effective treatment for advanced HCC with IVC and RA tumors, and small Ivalon particles (47-180 {mu}m) are superior to large ones (>180 {mu}m).« less

  2. Transcatheter arterial chemoembolization for advanced hepatocellular carcinoma with inferior vena cava and right atrial tumors.

    PubMed

    Chern, M C; Chuang, V P; Cheng, T; Lin, Z H; Lin, Y M

    2008-01-01

    Advanced hepatocelluar carcinoma (HCC) with invasion of venous systems usually indicates not only a poor prognosis but also a contraindication for transcatheter arterial chemoembolization (TACE). This study evaluated the feasibility of TACE for advanced HCC with inferior vena cava (IVC) and right atrium (RA) tumors and, also, to search for the ideal embolization particle size. Twenty-six patients who had HCC invasion into the IVC included five patients with coexistent RA tumors that were treated with TACE. The chemoembolization method was cisplatin, doxorubicin, and mitomycin C mixed with Lipiodol and Ivalon. The selection of Ivalon particles was divided into two groups based on their size: (A) >180 microm, N = 9; and (B) 47-180 microm, N = 17. The overall response rate was 53.8% (14/26). Based on the response to TACE, the median survival period of the entire group was 4.2 months (range, 1.5 to 76.7 months). The median survival period of the 14 responders was 13.5 months (1.5-76.7 months), and that of the 12 nonresponders, 3.3 months (2.1 to 24.3 months) (p < 0.002). Comparing the two Ivalon particle sizes, the response rate was 12.5% (1/8 [corrected] patients) for group A and 72.2% [corrected] for group B (13/18 [corrected] patients) (p < 0.01). [corrected] No serious complication was observed post-chemoembolization. In conclusion, TACE is a safe and effective treatment for advanced HCC with IVC and RA tumors, and small Ivalon particles (47-180 microm) are superior to large ones (>180 microm).

  3. Leiomyosarcoma of the Inferior Vena Cava - Radical Resection, Vascular Reconstruction and Challenges: A Case Report and Review of Relevant Literature

    PubMed Central

    Biswas, Saptarshi; Amin, Arpit; Chaudry, Suhaib; Joseph, Saju

    2013-01-01

    Leiomyosarcomas of the inferior Vena Cava (IVC) are rare soft tissue sarcomas accounting for only 0.5% of all soft tissue sarcomas in adults with fewer than 300 cases reported. Extraluminal tumor growth along the adventitia of the IVC seems to be the common presentation. Intraluminal tumor growth is rare. The origin of the tumor is divided into three levels in relation to the hepatic and renal veins. The presentations and surgical modalities vary accordingly. Retroperitoneal tumors are often not diagnosed until the disease is at an advanced stage with large tumor growth and involvement of surrounding structures. This is partly because of the nonspecific clinical presentation as well as absence of early symptoms. Most patients present with abdominal or flank pain. Symptoms vary according to the dimensions of the tumor, growth pattern and localization of the tumor. Radical en bloc resection of the affected venous segment remains the only therapeutic option associated with prolonged survival. The goals of surgical management of these tumors include the achievement of local tumor control, maintenance of caval flow, and the prevention of recurrence. The involvement of renal or hepatic veins determines the strategy for vascular reconstruction. Reconstruction of the IVC is not always required, because gradual occlusion of the IVC allows the development of venous collaterals. However, when pararenal leiomyosarcoma of the IVC is present, reconstruction of the IVC and the renal vein is necessary to prevent transient or permanent renal dysfunction. Recent study has shown that radical surgery combined with adjuvant multimodal therapy has improved the cumulative survival rate. We report a case of IVC leiomyosarcoma in a young healthy woman along with details of its diagnostic workup and discussion of the surgical options and reconstruction of caval continuity. PMID:29147340

  4. Comparison of two blood sampling techniques for the determination of coagulation parameters in the horse: Jugular venipuncture and indwelling intravenous catheter.

    PubMed

    Mackenzie, C J; McGowan, C M; Pinchbeck, G; Carslake, H B

    2018-05-01

    Evaluation of coagulation status is an important component of critical care. Ongoing monitoring of coagulation status in hospitalised horses has previously been via serial venipuncture due to concerns that sampling directly from the intravenous catheter (IVC) may alter the accuracy of the results. Adverse effects such as patient anxiety and trauma to the sampled vessel could be avoided by the use of an indwelling IVC for repeat blood sampling. To compare coagulation parameters from blood obtained by jugular venipuncture with IVC sampling in critically ill horses. Prospective observational study. A single set of paired blood samples were obtained from horses (n = 55) admitted to an intensive care unit by direct jugular venipuncture and, following removal of a presample, via an indwelling IVC. The following coagulation parameters were measured on venipuncture and IVC samples: whole blood prothrombin time (PT), fresh plasma PT and activated partial thromboplastin time (aPTT) and stored plasma antithrombin activity (AT) and fibrinogen concentration. D-dimer concentration was also measured in some horses (n = 22). Comparison of venipuncture and IVC results was performed using Lin's concordance correlation coefficient. Agreement between paired results was assessed using Bland Altman analysis. Correlation was substantial and agreement was good between sample methods for all parameters except AT and D-dimers. Each coagulation parameter was tested using only one assay. Sampling was limited to a convenience sample and timing of sample collection was not standardised in relation to when the catheter was flushed with heparinised saline. With the exception of AT and D-dimers, coagulation parameters measured on blood samples obtained via an IVC have clinically equivalent values to those obtained by jugular venipuncture. © 2017 EVJ Ltd.

  5. Phase II Randomized Trial of the Combination of Cetuximab and Sorafenib or Single Agent Cetuximab

    ClinicalTrials.gov

    2017-12-28

    Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Salivary Gland Squamous Cell Carcinoma; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer; Untreated Metastatic Squamous Neck Cancer With Occult Primary

  6. Sorafenib Tosylate, Cisplatin, and Docetaxel in Treating Patients With Recurrent or Metastatic Squamous Cell Carcinoma of the Head and Neck

    ClinicalTrials.gov

    2018-05-22

    Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Salivary Gland Squamous Cell Carcinoma; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Oral Cavity Squamous Cell Carcinoma; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer; Untreated Metastatic Squamous Neck Cancer With Occult Primary

  7. Respiratory-Induced Haemodynamic Changes: A Contributing Factor to IVC Filter Penetration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laborda, Alicia, E-mail: alaborda@unizar.es; Kuo, William T., E-mail: wkuo@stanford.edu; Ioakeim, Ignatios, E-mail: ignacio.ioakim@hotmail.es

    2015-10-15

    PurposeThe purpose of the study is to evaluate the influence of respiratory-induced vena caval hemodynamic changes on filter migration/penetration.Materials and MethodsAfter placement of either a Gunther Tulip or Celect IVC filter, 101 consecutive patients scheduled for filter retrieval were prospectively enrolled in this study. Pre-retrieval CT scans were used to assess filter complications and to calculate cross-sectional area in three locations: at level of filter strut fixation, 3 cm above and 3 cm below. A 3D finite element simulation was constructed on these data and direct IVC pressure was recorded during filter retrieval. Cross-sectional areas and pressures of the vena cava weremore » measured during neutral breathing and in Valsalva maneuver and identified filter complications were recorded. A statistical analysis of these variables was then performed.ResultsDuring Valsalva maneuvers, a 60 % decrease of the IVC cross-sectional area and a fivefold increase in the IVC pressure were identified (p < 0.001). There was a statistically significant difference in the reduction of the cross-sectional area at the filter strut level (p < 0.001) in patient with filter penetration. Difficulty in filter retrieval was higher in penetrated or tilted filters (p < 0.001; p = 0.005). 3D computational models showed significant IVC deformation around the filter during Valsalva maneuver.ConclusionCaval morphology and hemodynamics are clearly affected by Valsalva maneuvers. A physiological reduction of IVC cross-sectional area is associated with higher risk of filter penetration, despite short dwell times. Physiologic data should be used to improve future filter designs to remain safely implanted over longer dwell times.« less

  8. PI3K Inhibitor BKM120 and Cetuximab in Treating Patients With Recurrent or Metastatic Head and Neck Cancer

    ClinicalTrials.gov

    2017-05-22

    Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Salivary Gland Squamous Cell Carcinoma; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer

  9. Use of Cardiac Magnetic Resonance Imaging Based Measurements of Inferior Vena Cava Cross-Sectional Area in the Diagnosis of Pericardial Constriction.

    PubMed

    Hanneman, Kate; Thavendiranathan, Paaladinesh; Nguyen, Elsie T; Moshonov, Hadas; Wald, Rachel; Connelly, Kim A; Paul, Narinder S; Wintersperger, Bernd J; Crean, Andrew M

    2015-08-01

    To evaluate the value of cardiac magnetic resonance imaging (MRI)-based measurements of inferior vena cava (IVC) cross-sectional area in the diagnosis of pericardial constriction. Patients who had undergone cardiac MRI for evaluation of clinically suspected pericardial constriction were identified retrospectively. The diagnosis of pericardial constriction was established by clinical history, echocardiography, cardiac catheterization, intraoperative findings, and/or histopathology. Cross-sectional areas of the suprahepatic IVC and descending aorta were measured on a single axial steady-state free-precession (SSFP) image at the level of the esophageal hiatus in end-systole. Logistic regression and receiver-operating curve (ROC) analyses were performed. Thirty-six patients were included; 50% (n = 18) had pericardial constriction. Mean age was 53.9 ± 15.3 years, and 72% (n = 26) were male. IVC area, ratio of IVC to aortic area, pericardial thickness, and presence of respirophasic septal shift were all significantly different between patients with constriction and those without (P < .001 for all). IVC to aortic area ratio had the highest odds ratio for the prediction of constriction (1070, 95% confidence interval [8.0-143051], P = .005). ROC analysis illustrated that IVC to aortic area ratio discriminated between those with and without constriction with an area under the curve of 0.96 (95% confidence interval [0.91-1.00]). In patients referred for cardiac MRI assessment of suspected pericardial constriction, measurement of suprahepatic IVC cross-sectional area may be useful in confirming the diagnosis of constriction when used in combination with other imaging findings, including pericardial thickness and respirophasic septal shift. Copyright © 2015 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  10. A Multi-institutional Comparison of Adrenal Venous Sampling in Patients with Primary Aldosteronism: Caution Advised if Successful Bilateral Adrenal Vein Sampling is Not Achieved.

    PubMed

    Wang, Tracy S; Kline, Greg; Yen, Tina W; Yin, Ziyan; Liu, Ying; Rilling, William; So, Benny; Findling, James W; Evans, Douglas B; Pasieka, Janice L

    2018-02-01

    In patients with primary aldosteronism (PA), adrenal venous sampling (AVS) is recommended to differentiate between unilateral (UNI) or bilateral (BIL) adrenal disease. A recent study suggested that lateralization could be predicted, based on the ratio of aldosterone/cortisol levels (A/C) between the left adrenal vein (LAV) and inferior vena cava (IVC), with a 100% positive predictive value (PPV). This study aimed to validate those findings utilizing a larger, multi-institutional cohort. A retrospective review was performed of patients with PA who underwent AVS from 2 tertiary-care institutions. Laterality was predicted by an A/C ratio of >3:1 between the dominant and non-dominant adrenal. AVS results were compared to LAV/IVC ratios utilizing the published criteria (Lt ≥ 5.5; Rt ≤ 0.5). Of 222 patients, 124 (57%) had UNI and 98 (43%) had BIL disease based on AVS. AVS and LAV/IVC findings were concordant for laterality in 141 (64%) patients (69 UNI, 72 BIL). Using only the LAV/IVC ratio, 54 (24%) patients with UNI disease on AVS who underwent successful surgery would have been assumed to have BAH unless AVS was repeated, and 24 (11%) patients with BIL disease on AVS may have been incorrectly offered surgery (PPV 70%). Based on median LAV/IVC ratios (left 5.26; right 0.31; BIL 2.84), no LAV/IVC ratio accurately predicted laterality. This multi-institutional study of patients with both UNI and BIL PA failed to validate the previously reported PPV of LAV/IVC ratio for lateralization. Caution should be used in interpreting incomplete AVS data to differentiate between UNI versus BIL disease and strong consideration given to repeat AVS prior to adrenalectomy.

  11. Preface

    NASA Astrophysics Data System (ADS)

    Kövér, László

    2014-10-01

    This Special Issue of the journal Applied Surface Science contains full papers from a selection of contributions presented in the Applied Surface Science sessions of the 19th International Vacuum Congress (IVC-19) held in the Palais des Congrès, Paris, between September 9 and 13, 2013. The triennial IVC conferences represent major meetings in the field of the vacuum related sciences and are the largest scientific events of the International Union for Vacuum Science, Technique and Applications (IUVSTA). The IVC-19 and partner conferences had altogether 2555 participants. Supported by the Applied Surface Science Division of IUVSTA, the Applied Surface Science part was one of the most attended among the sub-conferences of the IVC-19. This Special Issue - without trying to achieve completeness - intends to provide a cross section of the topics of the Applied Surface Science and joint sessions of the IVC-19, covering important fields such as Surface Analysis, Surface Modifications, Surface Chemistry and Catalysis, Quantitative Surface and Interface Analysis, Coatings, Tribology, Adhesion, Characterization of Nanomaterials, Energy and Sustainable Development, Self Assembly, Nano-instrumentation, SPM and Novel Probe Techniques, New Approaches and Novel Applications of Surface/Interface Analytical Methods.

  12. Effects of processing parameters on immersion vacuum cooling time and physico-chemical properties of pork hams.

    PubMed

    Feng, Chao-Hui; Drummond, Liana; Zhang, Zhi-Hang; Sun, Da-Wen

    2013-10-01

    The effects of agitation (1002 rpm), different pressure reduction rates (60 and 100 mbar/min), as well as employing cold water with different initial temperatures (IWT: 7 and 20°C) on immersion vacuum cooling (IVC) of cooked pork hams were experimentally investigated. Final pork ham core temperature, cooling time, cooling loss, texture properties, colour and chemical composition were evaluated. The application for the first time of agitation during IVC substantially reduced the cooling time (47.39%) to 4.6°C, compared to IVC without agitation. For the different pressure drop rates, there was a trend that shorter IVC cooling times were achieved with lower cooling rate, although results were not statistically significant (P>0.05). For both IWTs tested, the same trend was observed: shorter cooling time and lower cooling loss were obtained under lower linear pressure drop rate of 60 mbar/min (not statistically significant, P>0.05). Compared to the reference cooling method (air blast cooling), IVC achieved higher cooling rates and better meat quality. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Identifying diversion of inferior vena cava after repair of atrial septal defect.

    PubMed

    Lee, Yi Wei; Lee, Wei Chieh; Chua, Sarah

    2015-10-01

    Inadvertent IVC diversion into left atrium is a rare morbidity following ASD repair. Reported risk factors included a large secundum, or low-lying ASD, or inferior sinus venosus defect, and anomalous pulmonary connection into the RA. In our case, transesophageal echocardiogram showed abnormal connection of IVC to LA, but could not be identified owing to limited window. Cardiac CT could offer better anatomic clarification. On contrast transesophageal echocardiogram with agitated saline injected via right femoral vein, an abnormal right-to-left shunt was demonstrated by transit of microbubbles from IVC into LA, while majority of rest entered into the RA. Therefore, we confirm the IVC diversion into LA. Detection of such unusual condition is a challenge due to the fact that special echocardiographic windows are often needed.

  14. Effects of embryo culture media do not persist after implantation: a histological study in mice.

    PubMed

    Hemkemeyer, Sandra A; Schwarzer, Caroline; Boiani, Michele; Ehmcke, Jens; Le Gac, Séverine; Schlatt, Stefan; Nordhoff, Verena

    2014-02-01

    Is post-implantation embryonic development after blastocyst transfer affected by exposure to different assisted reproduction technology (ART) culture media? Fetal development and placental histology of ART embryos cultured in vitro in different ART media was not impaired compared with embryos grown in vivo. The application of different in vitro culture (IVC) media for human ART has an effect on birthweight of newborns. In the mouse model, differences in blastocyst formation were reported after culture in different ART media. Moreover, abnormalities in the liver and heart have been detected as a result of suboptimal IVC conditions. Fertilized oocytes from inbred and outbred breeding schemes were retrieved and either immediately transferred to foster mothers or incubated in control or human ART culture media up to the blastocyst stage prior to transfer. Placental and fetal anatomy and particularly bone development were evaluated. B6C3F1 female mice were used as oocyte donors after ovulation induction. C57Bl/6 and CD1 males were used for mating and CD1 females as foster mothers for embryo transfer. Fertilized oocytes were recovered from mated females and incubated in sequential human ART media (ISM1/ISM2 and HTF/Multiblast), in control media [KSOM(aa) and Whitten's medium] or grown in utero without IVC (zygote control). As in vivo, control B6C3F1 females were superovulated and left untreated. Fetuses and placentae were isolated by Caesarean section and analysed at 18.5 days post-coitum (dpc) for placenta composition and at 15.5 dpc for body weight, crown-rump length (CRL), fetal organ development, morphological development, total bone length and extent of bone ossification. No major differences in the number of implantation sites or in histological appearance of the placentae were detected. CRL of KSOM(aa) fetuses was higher compared with zygote control and Whitten's medium. Histological analysis of tissue sections revealed no gross morphological differences compared with the in vitro groups or in vivo controls. Furthermore, no changes in skeletal development and degree of ossification were observed. However, fibula and tibia of ISM1/ISM2 fetuses were longer than the respective ones from in vivo fetuses. Findings in the mouse embryo and fetus may not be fully transferable to humans. In addition to skeletal development and placentation, there may be other parameters, e.g. on the molecular level which respond to IVC in ART media. Some comparisons have limited statistical power. Our data suggest that once implantation is achieved, subsequent post-implantation development unfolds normally, resulting in healthy fetuses. With mouse models, we gather information for the safety of human ART culture media. Our mouse study is reassuring for the safety of ART conditions on human embryonic development, given the lack of bold detrimental effects observed in the mouse model. This work was supported by the Deutsche Forschungsgemeinschaft (BO 2540/4-1 and SCHL 394/9-1) and by the Nederlandse Organisatie voor Wetenschappelijk Onderzoek (S.L.G.); Bilateral grant NWO-DFG 63-258. None of the authors has any conflict of interest to declare. Not applicable.

  15. The Effects of Adaptation to a Low Carbohydrate/High Fat Diet and Pre-Exercise Feeding on Exercise Endurance, Metabolism, and Cardiovascular Dynamics in Swine

    DTIC Science & Technology

    1988-01-01

    were obtained when initially (INITIAL) connected to the Inferior Vena Cava (IVC) or Hepatic Portal Vein (PV) catheters and just prior to feeding the...for metabolic measurements from the inferior vena cava (IVC) and the hepatic portal vein (PV) or for cardiovascular measurements (CV) from the...pulmonary artery and descending aorta with the ability to inject substances into the left atrium . Two pigs were initially instrumented for IVC and PV

  16. Vena cava thrombectomy and primary repair after radical nephrectomy for renal cell carcinoma: single-center experience.

    PubMed

    Helfand, Brian T; Smith, Norm D; Kozlowski, James M; Eskandari, Mark K

    2011-01-01

    Inferior vena cava (IVC) reconstruction for locally advanced renal cell carcinoma (RCC) includes resection with and without interposition grafting, patch graft, or primary repair. The proposed benefits of lateral venorrhaphy and primary repair are avoidance of foreign material, a more expeditious repair, and preservation of lower extremity venous outflow. A single-center retrospective review of 22 patients with RCC and IVC tumor thrombus treated with radical nephrectomy, lateral venorrhaphy, thrombectomy, and primary vena cava repair between July 2002 and June 2009 was carried out. Demographic data, diagnostic information, radiographic cross-sectional imaging, and procedural outcomes were examined. Among the 13 men and nine women, the mean age was 62.1 years (42-83); mean tumor size was 9.8 cm (3-17 cm), and 90% (n = 18) of the cases with RCC were identified pathologically as clear cell adenocarcinoma; on the basis of the classification system adopted by Neves, level I was for 50% (n = 11), level II for 32% (n = 7), level III for 9% (n = 2), and level IV for 9% (n = 2) of the patients. All patients underwent en bloc radical nephrectomy with tumor thrombus removal and primary IVC repair. Mean total operative time was 547.9 ± 138.5 minutes, whereas mean IVC cross-clamp time was 10.8 minutes (6-29 minutes). There were no intraoperative deaths or pulmonary embolism and all IVC margins were found to be pathologically negative. Postoperative complications included one pulmonary embolism, one exacerbation of chronic lymphedema, and two cases of new onset erectile dysfunction. Mean follow-up was 36.4 ± 23.2 months (6-92 months). There were no radiographic or clinically significant changes in mean IVC diameter during follow-up. Five late deaths (23%) occurred as a result of metastatic RCC over a mean period of 24 months (range, 12-48), but without any local recurrences. For advanced RCC with tumor thrombus extension into the IVC, lateral venorrhaphy and primary IVC repair avoids complicated caval reconstructions and results in high patency rates with a low local tumor recurrence rate. Copyright © 2011 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  17. Liver and Vena Cava En Bloc Resection for an Invasive Leiomyosarcoma Causing Budd-Chiari Syndrome, Under Veno-Venous Bypass and Liver Hypothermic Perfusion : Liver Hypothermic Perfusion and Veno-Venous Bypass for Inferior Vena Cava Leiomyosarcoma.

    PubMed

    Ravaioli, Matteo; Serenari, Matteo; Cescon, Matteo; Savini, Carlo; Cucchetti, Alessandro; Ercolani, Giorgio; Del Gaudio, Massimo; Casati, Alberto; Pinna, Antonio Daniele

    2017-02-01

    Leiomyosarcoma of vascular origin is a rare tumor, occurring mainly in the inferior vena cava (IVC). When involving the hepatic vein confluence, it often causes Budd-Chiari syndrome, and IVC removal with a complex hepatectomy is required (Mingoli in J Am Coll Surg 211:145-146, 2010; Griffin in J Surg Oncol 34:53-60, 1987; Heaney in Ann Surg 163:237-241, 1966; Fortner in Ann Surg 180:644-652, 1974). A 57-year-old male, without previous oncological history, presented with Budd-Chiari syndrome due to a leiomyosarcoma extending to the supra-diaphragmatic IVC and involving the right and middle hepatic veins. The patient did not receive neoadjuvant treatment. A femoral to superior vena cava veno-venous bypass was inserted, and both a median sternotomy and phreno-laparotomy with right subcostal extension were performed. A hemi-portocaval shunt was created between the right portal branch and the IVC, while a catheter was connected to the left portal branch for cold perfusion. Under extracorporeal circulation, the IVC was sectioned after infrahepatic and supra-diaphragmatic cross-clamping. The left liver was flushed with Celsior solution and packed with ice. A right trisectionectomy extended to the caudate lobe with en bloc vena cava removal was performed. The IVC was replaced by a cryopreserved aortic homograft, to which the stump of the left hepatic vein was anastomosed. Bypass duration, warm and cold liver ischemia, and operation time were 280 min, 8 min, 112 min, and 11 h, respectively. Duct-to-duct biliary anastomosis tutored by a T-tube was performed, and the patient was discharged on postoperative day 29, without major complications. After 16 months free of disease, the patient developed bilateral lung metastases. After 4 years the patient is still alive and receiving systemic chemotherapy. Leiomyosarcoma of the IVC involving the hepatic veins can be treated with extended hepatectomy and removal of the IVC through extracorporeal circulation.

  18. Pheochromocytoma with inferior vena cava thrombosis: An unusual association.

    PubMed

    Kota, Sunil K; Kota, Siva K; Jammula, Sruti; Meher, Lalit K; Modi, Kirtikumar D

    2012-04-01

    Pheochromocytomas have been described in association with vascular abnormalities like renal artery stenosis. A 48-year-old man was admitted to our hospital with the complaints of headache, sweating, anxiety, dizziness, nausea, vomiting and hypertension. For last several days, he was having a dull aching abdominal pain. Abdominal computed tomography (CT) revealed the presence of a left adrenal pheochromocytoma. An inferior vena cava (IVC) venogram via the right jugular vein demonstrated occlusion of the IVC inferior to the right atrium. Surgical removal of pheochromocytoma was done, followed by anticoagulant treatment for IVC thrombosis, initially with subcutaneous low molecular weight heparin, and then with oral warfarin, resulting in restoration of patency. To the best of our knowledge, the occurrence of pheochromocytoma in IVC thrombosis has not been reported so far from India. Possible mechanisms of such an involvement are discussed.

  19. Novel and Advanced Techniques for Complex IVC Filter Retrieval.

    PubMed

    Daye, Dania; Walker, T Gregory

    2017-04-01

    Inferior vena cava (IVC) filter placement is indicated for the treatment of venous thromboembolism (VTE) in patients with a contraindication to or a failure of anticoagulation. With the advent of retrievable IVC filters and their ease of placement, an increasing number of such filters are being inserted for prophylaxis in patients at high risk for VTE. Available data show that only a small number of these filters are retrieved within the recommended period, if at all, prompting the FDA to issue a statement on the need for their timely removal. With prolonged dwell times, advanced techniques may be needed for filter retrieval in up to 60% of the cases. In this article, we review standard and advanced IVC filter retrieval techniques including single-access, dual-access, and dissection techniques. Complicated filter retrievals carry a non-negligible risk for complications such as filter fragmentation and resultant embolization of filter components, venous pseudoaneurysms or stenoses, and breach of the integrity of the caval wall. Careful pre-retrieval assessment of IVC filter position, any significant degree of filter tilting or of hook, and/or strut epithelialization and caval wall penetration by filter components should be considered using dedicated cross-sectional imaging for procedural planning. In complex cases, the risk for retrieval complications should be carefully weighed against the risks of leaving the filter permanently indwelling. The decision to remove an embedded IVC filter using advanced techniques should be individualized to each patient and made with caution, based on the patient's age and existing comorbidities.

  20. CT of inferior vena cava filters: normal presentations and potential complications.

    PubMed

    Georgiou, Nicholas A; Katz, Douglas S; Ganson, George; Eng, Kaitlin; Hon, Man

    2015-12-01

    With massive pulmonary embolism (PE) being the first or second leading cause of unexpected death in adults, protection against PE is critical in appropriately selected patients. The use of inferior vena cava (IVC) filters has increased over the years, paralleling the increased detection of deep venous thrombosis (DVT) and PE by improved and more available imaging techniques. The use of IVC filters has become very common as an alternative and/or as a supplement to anticoagulation, and these filters are often seen on routine abdominal CT, including in the emergency setting; therefore, knowledge of the normal spectrum of findings of IVC filters by the radiologist on CT is critical. Additionally, CT can be used specifically to identify complications related to IVC filters, and CT may alternatively demonstrate IVC filter-related problems which are not specifically anticipated clinically. With multiple available IVC filters on the US market, and even more available outside of the USA, it is important for the emergency and the general radiologist to recognize the different models and various appearances and positioning on CT, as well as their potential complications. These complications may be related to venous access, but also include thrombosis related to the filter, filter migration and penetration, and problems associated with filter deployment. With the increasing number of inferior vena cava filters placed and their duration within patients increasing over time, it is critical for emergency and other radiologists to be aware of these findings on CT.

  1. Practice patterns of retrievable inferior vena cava filters and predictors of filter retrieval in patients with pulmonary embolism.

    PubMed

    Kang, Jieun; Ko, Heung-Kyu; Shin, Ji Hoon; Ko, Gi-Young; Jo, Kyung-Wook; Huh, Jin Won; Oh, Yeon-Mok; Lee, Sang-Do; Lee, Jae Seung

    2017-12-01

    Retrievable inferior vena cava (IVC) filters are increasingly used in patients with venous thromboembolism (VTE) who have contraindications to anticoagulant therapy. However, previous studies have shown that many retrievable filters are left permanently in patients. This study aimed to identify the common indications for IVC filter insertion, the filter retrieval rate, and the predictive factors for filter retrieval attempts. To this end, a retrospective cohort study was performed at a tertiary care center in South Korea between January 2010 and May 2016. Electronic medical charts were reviewed for patients with pulmonary embolism (PE) who underwent IVC filter insertion. A total of 439 cases were reviewed. The most common indication for filter insertion was a preoperative/procedural aim, followed by extensive iliofemoral deep vein thrombosis (DVT). Retrieval of the IVC filter was attempted in 44.9% of patients. The retrieval success rate was 93.9%. History of cerebral hemorrhage, malignancy, and admission to a nonsurgical department were the significant predictive factors of a lower retrieval attempt rate in multivariate analysis. With the increased use of IVC filters, more issues should be addressed before placing a filter and physicians should attempt to improve the filter retrieval rate.

  2. "Passing loop" technique: a new modification of the piggyback technique tailored to voluminous liver grafts--case report.

    PubMed

    Eldeen, F Z; Lee, C-F; Lee, C-S; Chan, K-M; Lee, W-C

    2013-03-01

    The modified piggyback technique with side-to-side cavocavostomy decreases the risk of outflow obstruction compared with the standard piggyback method. However, this modification is not ideal for recipients who receive a graft that is voluminous or bears an enlarged caudate lobe. We modified the inferior vena cava (IVC) preservation technique against deleterious complications of compression by using a passing loop. A 49-year-old woman, who underwent orthotopic liver transplantation for hepatic failure, was allocated a large-size liver. In anticipation of serious caval compression due to the voluminous grafts, we kept the suprahepatic or infrahepatic donor caval cuffs open for an anastomosis. The first anastomosis was performed between suprahepatic donor IVC cuff and recipient middle-left hepatic vein common channel; the second anastomosis was a terminolateral cavocavostomy between infrahepatic donor IVC cuff and the anterior wall of the recipient's IVC. When the liver circulation was restored, the donor retrohepatic vena cava served as a passing loop for both hepatic venous outflow and infra-diaphragmatic venous return to bypass possible IVC compression. Our technique may solve a dilemna for patients receiving voluminous liver grafts. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Twin Valve Caval Stent for Functional Replacement of Incompetent Tricuspid Valve: A Feasibility Animal Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sochman, Jan, E-mail: jan.sochman@medicon.cz; Peregrin, Jan H., E-mail: jape@medicon.cz; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu

    Objective: To evaluate feasibility of a twin valve caval stent (TVCS) for functional replacement of an incompetent tricuspid valve (TV) in an acute animal study. Methods: One swine and three sheep were used in the study. TVCS placement was tested in a swine with a normal TV. TVCS function was tested in three sheep with TV regurgitation created by papillary muscle avulsion. Cardiac angiograms and pressure measurements were used to evaluate TVCS function. Two sheep were studied after fluid overload. Results: TVCS was percutaneously placed properly at the central portions of the superior vena cava (SVC) and inferior vena cavamore » (IVC) in the swine. Papillary muscle avulsion in three sheep caused significant tricuspid regurgitation with massive reflux into the right atrium (RA) and partial reflux into the SVC and IVC. TVCS placement eliminated reflux into the SVC and IVC. After fluid overload, there was enlargement of the right ventricle and RA and significant increase in right ventricle, RA, SVC, and IVC pressures, but no reflux into the IVC and SVC. Conclusion: The results of this feasibility study justify detailed evaluation of TVCS insertion for functional chronic replacement of incompetent TV.« less

  4. Community health worker interventions are key to optimal infant immunization coverage, evidence from a pretest-posttest experiment in Mwingi, Kenya.

    PubMed

    Nzioki, Japheth Mativo; Ouma, James; Ombaka, James Hebert; Onyango, Rosebella Ongutu

    2017-01-01

    Immunization is a powerful and cost-effective health intervention which averts an estimated 2 to 3 million deaths every year. Kenya has a high infant and under five mortality and morbidity rates. Increasing routine child immunization coverage is one way of reducing child morbidity and mortality rates in Kenya. Community Health Workers (CHWs) have emerged as critical human resources for health in developing countries. The Community Strategy (CS) is one of the CHW led interventions promoting Maternal and Child Health (MCH) in Kenya. This study sought to establish the effect of CS on infant vaccination Coverage (IVC) in Mwingi west sub-county; Kenya. This was a pretest - posttest experimental study design with 1 pretest and 2 post-test surveys conducted in intervention and control sites. Mwingi west and Mwingi north sub-counties where intervention and control sites respectively. Sample size in each survey was 422 households. Women with a child aged 9-12 months were main respondents. Intervention site end-term evaluation indicated that; the CS increased IVC by 10.1% (Z =6.0241, P <0.0001), from a suboptimal level of 88.7% at baseline survey to optimal level of 98.8% at end term survey. Infants in intervention site were 2.5 times more likely to receive all recommended immunizations within their first year of life [(crude OR= 2.475, P<0.0001; 95%CI: 1.794-3.414) (adj. OR=2.516, P<0.0001; 95%CI: 1.796-3.5240)]. CS increased IVC in intervention site to optimal level (98.8%). To improve child health outcomes through immunization coverage, Kenya needs to fast-track nationwide implementation of the CS intervention.

  5. Community health worker interventions are key to optimal infant immunization coverage, evidence from a pretest-posttest experiment in Mwingi, Kenya

    PubMed Central

    Nzioki, Japheth Mativo; Ouma, James; Ombaka, James Hebert; Onyango, Rosebella Ongutu

    2017-01-01

    Introduction Immunization is a powerful and cost-effective health intervention which averts an estimated 2 to 3 million deaths every year. Kenya has a high infant and under five mortality and morbidity rates. Increasing routine child immunization coverage is one way of reducing child morbidity and mortality rates in Kenya. Community Health Workers (CHWs) have emerged as critical human resources for health in developing countries. The Community Strategy (CS) is one of the CHW led interventions promoting Maternal and Child Health (MCH) in Kenya. This study sought to establish the effect of CS on infant vaccination Coverage (IVC) in Mwingi west sub-county; Kenya. Methods This was a pretest - posttest experimental study design with 1 pretest and 2 post-test surveys conducted in intervention and control sites. Mwingi west and Mwingi north sub-counties where intervention and control sites respectively. Sample size in each survey was 422 households. Women with a child aged 9-12 months were main respondents. Results Intervention site end-term evaluation indicated that; the CS increased IVC by 10.1% (Z =6.0241, P <0.0001), from a suboptimal level of 88.7% at baseline survey to optimal level of 98.8% at end term survey. Infants in intervention site were 2.5 times more likely to receive all recommended immunizations within their first year of life [(crude OR= 2.475, P<0.0001; 95%CI: 1.794-3.414) (adj. OR=2.516, P<0.0001; 95%CI: 1.796-3.5240)]. Conclusion CS increased IVC in intervention site to optimal level (98.8%). To improve child health outcomes through immunization coverage, Kenya needs to fast-track nationwide implementation of the CS intervention. PMID:29138657

  6. Inferior Vena Cava Oxygen Saturation during the First Three Postnatal Days in Preterm Newborns with and without Patent Ductus Arteriosus

    PubMed Central

    Yapakçı, Ece; Ecevit, Ayşe; İnce, Deniz Anuk; Gökdemir, Mahmut; Tekindal, M. Agah; Gülcan, Hande; Tarcan, Aylin

    2014-01-01

    Background: Inferior vena cava (IVC) oxygen saturation as an indicator of mixed venous oxygenation may be valuable for understanding postnatal adaptations in newborn infants. It is unknown how this parameter progresses in critically ill premature infants. Aims: To investigate IVC oxygen saturation during the first three days of life in preterm infants with and without patent ductus arteriosus (PDA). Study Design: Case-control study. Methods: Twenty-seven preterm infants were admitted to the Neonatal Intensive Care. Preterm infants with umbilical venous catheterization were included in the study. Six umbilical venous blood gas values were obtained from each infant during the first 72 hours of life. Preterm infants in the study were divided into two groups. Haemodynamically significant PDA was diagnosed by echocardiography in 11 (41%) infants before the 72nd hour of life in the study group and ibuprofen treatment was started, whereas 16 (59%) infants who didn’t have haemodynamically significant PDA were included in the control group. Results: In the entire group, the highest value of mean IVC oxygen saturation was 79.9% at the first measurement and the lowest was 64.8% at the 72nd hour. Inferior vena cava oxygen saturations were significantly different between the study and control groups. Post-hoc analysis revealed that the first and 36th hour measurements made the difference (p=0.01). Conclusion: Inferior vena cava oxygen saturation was found to be significantly different between preterm infants with and without PDA. Further studies are needed to understand the effect of foetal shunts on venous oxygenation during postnatal adaptation in newborn infants. PMID:25337418

  7. Iliocaval Confluence Stenting for Chronic Venous Obstructions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Graaf, Rick de, E-mail: r.de.graaf@mumc.nl; Wolf, Mark de, E-mail: markthewolf@gmail.com; Sailer, Anna M., E-mail: anni.sailer@mumc.nl

    PurposeDifferent techniques have been described for stenting of venous obstructions. We report our experience with two different confluence stenting techniques to treat chronic bi-iliocaval obstructions.Materials and MethodsBetween 11/2009 and 08/2014 we treated 40 patients for chronic total bi-iliocaval obstructions. Pre-operative magnetic resonance venography showed bilateral extensive post-thrombotic scarring in common and external iliac veins as well as obstruction of the inferior vena cava (IVC). Stenting of the IVC was performed with large self-expandable stents down to the level of the iliocaval confluence. To bridge the confluence, either self-expandable stents were placed inside the IVC stent (24 patients, SECS group) ormore » high radial force balloon-expandable stents were placed at the same level (16 patients, BECS group). In both cases, bilateral iliac extensions were performed using nitinol stents.ResultsRecanalization was achieved for all patients. In 15 (38 %) patients, a hybrid procedure with endophlebectomy and arteriovenous fistula creation needed to be performed because of significant involvement of inflow vessels below the inguinal ligament. Mean follow-up was 443 ± 438 days (range 7–1683 days). For all patients, primary, assisted-primary, and secondary patency rate at 36 months were 70, 73, and 78 %, respectively. Twelve-month patency rates in the SECS group were 85, 85, and 95 % for primary, assisted-primary, and secondary patency. In the BECS group, primary patency was 100 % during a mean follow-up period of 134 ± 118 (range 29–337) days.ConclusionStenting of chronic bi-iliocaval obstruction shows relatively high patency rates at medium follow-up. Short-term patency seems to favor confluence stenting with balloon-expandable stents.« less

  8. Catheter-Directed Thrombolysis of Inferior Vena Cava Thrombosis in a 13-Day-Old Neonate and Review of Literature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khan, Jawad U.; Takemoto, Clifford M.; Casella, James F.

    Complete inferior vena cava thrombosis (IVC) in neonates is uncommon, but may cause significant morbidity. A 13-day-old neonate suffered IVC thrombosis secondary to antithrombin III deficiency, possibly contributed to by a mutation in the methyl tetrahydrofolate reductase gene. Catheter-directed thrombolysis (CDT) with recombinant tissue plasminogen activator (rt-PA, Alteplase) was used successfully to treat extensive venous thrombosis in this neonate without complications. We also review the literature on CDT for treatment of IVC thrombosis in critically ill neonates and infants.

  9. A Novel Technique for Inferior Vena Cava Filter Extraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnston, Edward William, E-mail: ed.johnston@doctors.org.uk; Rowe, Luke Michael Morgan; Brookes, Jocelyn

    Inferior vena cava (IVC) filters are used to protect against pulmonary embolism in high-risk patients. Whilst the insertion of retrievable IVC filters is gaining popularity, a proportion of such devices cannot be removed using standard techniques. We describe a novel approach for IVC filter removal that involves snaring the filter superiorly along with the use of flexible forceps or laser devices to dissect the filter struts from the caval wall. This technique has used to successfully treat three patients without complications in whom standard techniques failed.

  10. IVC filter placements in children: nationwide comparison of practice patterns at adult and children's hospitals using the Kids' Inpatient Database.

    PubMed

    Wadhwa, Vibhor; Trivedi, Premal S; Ali, Sumera; Ryu, Robert K; Pezeshkmehr, Amir

    2018-02-01

    Inferior vena cava (IVC) filter placement in children has been described in literature, but there is variability with regard to their indications. No nationally representative study has been done to compare practice patterns of filter placements at adult and children's hospitals. To perform a nationally representative comparison of IVC filter placement practices in children at adult and children's hospitals. The 2012 Kids' Inpatient Database was searched for IVC filter placements in children <18 years of age. Using the International Classification of Diseases, 9th Revision (ICD-9) code for filter insertion (38.7), IVC filter placements were identified. A small number of children with congenital cardiovascular anomalies codes were excluded to improve specificity of the code used to identify filter placement. Filter placements were further classified by patient demographics, hospital type (children's and adult), United States geographic region, urban/rural location, and teaching status. Statistical significance of differences between children's or adult hospitals was determined using the Wilcoxon rank sum test. A total of 618 IVC filter placements were identified in children <18 years (367 males, 251 females, age range: 5-18 years) during 2012. The majority of placements occurred in adult hospitals (573/618, 92.7%). Significantly more filters were placed in the setting of venous thromboembolism in children's hospitals (40/44, 90%) compared to adult hospitals (246/573, 43%) (P<0.001). Prophylactic filters comprised 327/573 (57%) at adult hospitals, with trauma being the most common indication (301/327, 92%). The mean length of stay for patients receiving filters was 24.5 days in children's hospitals and 18.4 days in adult hospitals. The majority of IVC filters in children are placed in adult hospital settings. Children's hospitals are more likely to place therapeutic filters for venous thromboembolism, compared to adult hospitals where the prophylactic setting of trauma predominates.

  11. [Differences in influenza vaccination coverage among subgroups of adult immigrants residing in Italy at risk for complications (2012-2013)].

    PubMed

    Fabiani, Massimo; Di Napoli, Anteo; Riccardo, Flavia; Gargiulo, Lidia; Declich, Silvia; Petrelli, Alessio

    2017-01-01

    to evaluate differences in influenza vaccination coverage (IVC) in immigrants at risk for influenza-related complications, according to their area of origin and length of stay in Italy. cross-sectional survey conducted on the sample of foreign citizens included in the survey on health conditions and use of health services of the Italian resident population (Italian national institute of statistics, 2012-2013). analysis conducted on 885 foreign adult citizens (≥18 years) at risk for influenza-related complications (elderly residents ≥65 years and residents with specific chronic diseases). vaccination coverage ratios (VCR) comparison between long-term immigrants (≥10 years) and recent immigrants (<10 years), and between non-African and African immigrants, adjusted by demographic and socioeconomic characteristics and level of health services utilization. IVC among immigrants was 15.6%, significantly higher in long-term immigrants (18.3%) compared to recent immigrants (10.2%) (VCR: 1.79; 95%CI 1.21-2.66), and in non-African immigrants (17.1%) compared to African immigrants (9.4%) (VCR: 1.82; 95%CI 1.04-3.17). After adjusting on the basis of demographic and socioeconomic characteristics and for level of health services utilization between the compared subgroups, the difference in IVC according to the length of stay was greatly reduced (VCR: 1.41; 95%CI 0.94- 2.10), while IVC difference reduction according to area of origin was less relevant (VCR: 1.66; 95%CI 0.95-2.91). demographic and socioeconomic characteristics and level of health services utilization explained part of the difference in IVC between the compared subgroups, particularly between long-term and recent immigrants. The difference in IVC between African immigrants and immigrants from other areas remained quite pronounced even after adjusting on the basis of these factors. This suggests that IVC, especially in African immigrants, is affected by other informal barriers, such as cultural and linguistic barriers, that need to be addressed when planning effective immunization access strategies.

  12. Chemotherapy With or Without Bevacizumab in Treating Patients With Recurrent or Metastatic Head and Neck Squamous Cell Carcinoma

    ClinicalTrials.gov

    2018-06-19

    Recurrent Hypopharyngeal Squamous Cell Carcinoma; Recurrent Laryngeal Squamous Cell Carcinoma; Recurrent Laryngeal Verrucous Carcinoma; Recurrent Lip and Oral Cavity Squamous Cell Carcinoma; Recurrent Metastatic Squamous Cell Carcinoma in the Neck With Occult Primary; Recurrent Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Recurrent Oral Cavity Verrucous Carcinoma; Recurrent Oropharyngeal Squamous Cell Carcinoma; Recurrent Salivary Gland Carcinoma; Salivary Gland Squamous Cell Carcinoma; Squamous Cell Carcinoma Metastatic in the Neck With Occult Primary; Stage IV Hypopharyngeal Squamous Cell Carcinoma AJCC v7; Stage IV Major Salivary Gland Cancer AJCC v7; Stage IVA Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVA Laryngeal Verrucous Carcinoma AJCC v7; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVA Major Salivary Gland Cancer AJCC v7; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVA Oral Cavity Cancer AJCC v6 and v7; Stage IVA Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Laryngeal Verrucous Carcinoma AJCC v7; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVB Major Salivary Gland Cancer AJCC v7; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVB Oral Cavity Cancer AJCC v6 and v7; Stage IVB Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVC Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVC Laryngeal Verrucous Carcinoma AJCC v7; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVC Major Salivary Gland Cancer AJCC v7; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVC Oral Cavity Cancer AJCC v6 and v7; Stage IVC Oropharyngeal Squamous Cell Carcinoma AJCC v7; Tongue Carcinoma; Untreated Metastatic Squamous Cell Carcinoma to Neck With Occult Primary

  13. A rare nidus for pulmonary thromboembolism after vertebroplasty.

    PubMed

    Vallabhajosyula, Saraschandra; Sundaragiri, Pranathi Rao; Bansal, Ojas; Townley, Theresa A

    2013-10-23

    Percutaneous vertebroplasty is used to treat osteoporotic compression fractures and bone loss due to malignancy. The cement used can serve as a potential nidus for pulmonary thromboembolism (PTE). An 87-year-old woman with recent L2 vertebroplasty presented with abdominal pain and shortness of breath. Thoracoabdominal CT scan revealed extensive bilateral pulmonary emboli associated with a 9 cm cement fragment in the inferior vena cava (IVC) extending proximally from the level of the right superior renal vein, likely secondary to cement leak from the vertebral plexus into the IVC. She refused catheter extraction was managed conservatively. There are 51 reported cases of cement pulmonary embolism. IVC foreign bodies serving as a nidus for PTE have been reported with IVC filters with an incidence of 6.2%. This is the second reported case of vertebroplasty cement serving as a nidus for PTE. Treatment depends on time interval between the procedure and the symptom onset.

  14. Congenital extrahepatic portosystemic shunt (Abernethy malformation) treated endovascularly with vascular plug shunt closure.

    PubMed

    Passalacqua, Matthew; Lie, Kevin T; Yarmohammadi, Hooman

    2012-01-01

    A 3-year-old boy, who presented with progressive cyanosis and hypoxia, was diagnosed with a large congenital extrahepatic portosystemic shunt, interrupted IVC with azygos continuation, and multiple congenital anomalies. Traditionally open and laparoscopic surgical techniques have been used to treat this malformation. Endovascular repair using a 16-mm Amplatzer vascular plug (AGA Medical Corporation, Golden Valley, Minnesota, USA) was used to occlude the shunt. Immediate post-placement venography demonstrated cessation of flow within the shunt and increased portal venous flow. The patient's hypoxia and cyanosis decreased significantly, and he was discharged on the 5th post-procedure day in stable clinical condition. Three months follow-up evaluation demonstrated the vascular plug in place, unchanged in position.

  15. Inferior vena cava filter retrievals, standard and novel techniques.

    PubMed

    Kuyumcu, Gokhan; Walker, T Gregory

    2016-12-01

    The placement of an inferior vena cava (IVC) filter is a well-established management strategy for patients with venous thromboembolism (VTE) disease in whom anticoagulant therapy is either contraindicated or has failed. IVC filters may also be placed for VTE prophylaxis in certain circumstances. There has been a tremendous growth in placement of retrievable IVC filters in the past decade yet the majority of the devices are not removed. Unretrieved IVC filters have several well-known complications that increase in frequency as the filter dwell time increases. These complications include caval wall penetration, filter fracture or migration, caval thrombosis and an increased risk for lower extremity deep vein thrombosis (DVT). Difficulty is sometimes encountered when attempting to retrieve indwelling filters, mainly because of either abnormal filter positioning or endothelization of filter components that are in contact with the IVC wall, thereby causing the filter to become embedded. The length of time that a filter remains indwelling also impacts the retrieval rate, as increased dwell times are associated with more difficult retrievals. Several techniques for difficult retrievals have been described in the medical literature. These techniques range from modifications of standard retrieval techniques to much more complex interventions. Complications related to complex retrievals are more common than those associated with standard retrieval techniques. The risks of complex filter retrievals should be compared with those of life-long anticoagulation associated with an unretrieved filter, and should be individualized. This article summarizes current techniques for IVC filter retrieval from a clinical point of view, with an emphasis on advanced retrieval techniques.

  16. Inferior vena cava filter retrievals, standard and novel techniques

    PubMed Central

    Walker, T. Gregory

    2016-01-01

    The placement of an inferior vena cava (IVC) filter is a well-established management strategy for patients with venous thromboembolism (VTE) disease in whom anticoagulant therapy is either contraindicated or has failed. IVC filters may also be placed for VTE prophylaxis in certain circumstances. There has been a tremendous growth in placement of retrievable IVC filters in the past decade yet the majority of the devices are not removed. Unretrieved IVC filters have several well-known complications that increase in frequency as the filter dwell time increases. These complications include caval wall penetration, filter fracture or migration, caval thrombosis and an increased risk for lower extremity deep vein thrombosis (DVT). Difficulty is sometimes encountered when attempting to retrieve indwelling filters, mainly because of either abnormal filter positioning or endothelization of filter components that are in contact with the IVC wall, thereby causing the filter to become embedded. The length of time that a filter remains indwelling also impacts the retrieval rate, as increased dwell times are associated with more difficult retrievals. Several techniques for difficult retrievals have been described in the medical literature. These techniques range from modifications of standard retrieval techniques to much more complex interventions. Complications related to complex retrievals are more common than those associated with standard retrieval techniques. The risks of complex filter retrievals should be compared with those of life-long anticoagulation associated with an unretrieved filter, and should be individualized. This article summarizes current techniques for IVC filter retrieval from a clinical point of view, with an emphasis on advanced retrieval techniques. PMID:28123984

  17. Effect of Ventilated Caging on Water Intake and Loss in 4 Strains of Laboratory Mice

    PubMed Central

    Nicolaus, Mackenzie L; Bergdall, Valerie K; Davis, Ian C; Hickman-Davis, Judy M

    2016-01-01

    Food availability, temperature, humidity, strain, and caging type all affect water consumption by mice. Measurement of transepidermal water loss (TEWL) is a new technique for the quantification of water turnover in mice. To understand water turnover in common strains of adult mice, male and female SCID, SKH, C57BL/6, and FVB mice were housed in same-sex groups of 5 animals in static cages or IVC. Body weight, TEWL, urine osmolality, and water consumption of mice and intracage temperature and humidity were measured every 48 h for comparison. Static cages were monitored for 7 d and IVC for 14 d before cage change. Female SCID, FVB, and C57 mice drank less water than did their male counterparts. Male and female SCID, SKH, and FVB mice in IVC drank less water and had higher urine osmolality than did those in static cages. In SCID and SKH mice, TEWL paralleled water consumption. C57 mice in static cages drank less water, had lower urine osmolality, and had less TEWL than did those in IVC. Temperature and humidity within the cage was higher than the macroenvironmental levels for all housing conditions, mouse strains, and sexes. Temperatures within IVC ranged from 76.6 to 81.4 °F compared with 69 ± 0.4 °F in the room. Humidity within IVC ranged from 68% to 79% compared with 27.o% ± 2.7% within the room. These data demonstrate that mouse strain and housing conditions significantly influence water balance and indicate that macroenvironmental measurements do not always reflect the intracage environment. PMID:27657706

  18. Successful operative treatment of uterine leiomyoma with extensive intravenous extension to the IVC, right heart, and pulmonary arteries.

    PubMed

    Brar, Ranjeet; Skervin, Alicia; El-Sakka, Karim; Fish, Andrew; Lewis, Michael

    2018-01-17

    Intravenous extension of benign uterine leiomyomata ('fibroids'), in the absence of discrete metastatic disease has rarely been reported. 'Fibroids' remain one of the most common premenopausal uterine pathologies. We report the diagnosis and multidisciplinary led operative management of a 52-year-old woman with a histologically benign, but biologically aggressive, uterine leiomyoma with intravenous extension to the inferior vena cava (IVC), right heart and pulmonary arteries. Total abdominal hysterectomy and bilateral salpingo-oophorectomy combined with exploration of the sub-hepatic IVC and heart under deep hypothermic circulatory arrest achieved its successful macroscopic clearance.

  19. Two cases of scimitar variant.

    PubMed

    Takeda, S; Imachi, T; Arimitsu, K; Minami, M; Hayakawa, M

    1994-01-01

    The scimitar sign is characteristic of partial anomalous pulmonary venous drainage into the inferior vena cava (IVC). We encountered two variant cases of scimitar sign. In one case, the scimitar vein entered both the IVC and the left atrium (LA) without any intracardiac shunts. Surgical repair was made by simple ligation of the scimitar vein to correct the left to right shunt. Retrograde balloon occlusion angiography of the scimitar vein was diagnostic. In the other case, the scimitar vein showed a meandering course, and then drained into the LA without any connection with the IVC, and surgical intervention was not required.

  20. Effective control of massive venous bleeding by "multioverlapping therapy" using polysaccharide nanosheets in a rabbit inferior vena cava injury model.

    PubMed

    Hagisawa, Kohsuke; Saito, Akihiro; Kinoshita, Manabu; Fujie, Toshinori; Otani, Naoki; Shono, Satoshi; Park, Young-Kwang; Takeoka, Shinji

    2013-07-01

    To investigate the efficacy of multioverlapping therapy using a polysaccharide nanosheet having 75-nm thickness for sealing and stopping massive venous hemorrhage. The hydrostatic durability of the polysaccharide nanosheet was evaluated in vitro when secured to an incised silicon tube. For in vivo studies, the inferior vena cava (IVC) of rabbits was cut longitudinally, and multiple polysaccharide nanosheets were overlapped onto the injured IVC. The mechanical hydrostatic durability of the nanosheets was gradually augmented by an increasing number of multilayered nanosheets in vitro. This durability was saturated at 80 ± 6 mm Hg by four layers of nanosheets, which was robust enough to seal injured vessel walls of the large IVC. Multioverlapping therapy using nanosheets effectively sealed and stopped bleeding from the injured IVC in vivo. One month later, no inflammatory tissue response was observed around the nanosheet attachment sites of the IVC, while conventional suturing repair in control rabbits showed a severe inflammatory response around the sutured area. The multioverlapping therapy using the polysaccharide nanosheets will effectively stop massive venous bleeding without adverse effects in the immediate or chronic postoperative setting. Copyright © 2013 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  1. Chronic Pain Syndrome Caused by a Bird's Nest Filter: First Case Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Al-Basheer, Mamoun Ahmad, E-mail: drbasheer30@yahoo.co; Hamilton, Mark; Holdaway, Chris

    2008-07-15

    AimTo report the first case of a Bird's Nest IVC filter causing a chronic pain syndrome lasting 13 years through IVC wall penetration and subsequent break off of one of the filter struts.Materials and ResultsA 43-year-old female presented with a 13-year history of abdominal pain following uneventful insertion of a Bird's Nest vena cava filter through a right internal jugular percutanous approach. A year following the procedure, CT scan revealed one arm of the filter to be outside IVC borders. Nine years from the date of insertion the nature of the pain changed acutely following a five feet jump tomore » more localized RUQ pain worse with twisting movements. A CT scan showed the strut to have pierced the IVC wall and penetrated the Unicate process of pancreas. Plain x-rays taken at different times in February 2006 showed one of the struts to be free floating in the peritoneal cavity. The floating strut was removed surgically from the wall of the Ileum. Postoperative recovery was uneventful and the patient was discharged pain free three days later.ConclusionChronic pain is an added complication of BNF devices. Although rare, it further emphasizes the need for long-term follow up of patients with IVC filters.« less

  2. Congenital Vitelline Band Causing Intestinal Obstruction in an Adult with a Double Inferior Vena Cava

    PubMed Central

    Pussepitiya, Kumari; Samarasinghe, Bandula; Wickramasinghe, Nuwan

    2016-01-01

    Introduction. Vitelline artery remnants are rare causes of intra-abdominal bands leading to bowel obstruction. These bands may be associated with Meckel's diverticulum. Double inferior vena cava (IVC) is a rare presentation and is usually identified incidentally. Case Presentation. A sixty-year-old male presented with progressive vomiting for five days and he was clinically diagnosed with intestinal obstruction. Plain X-ray abdomen showed evidence of small bowel obstruction. CT scan of the abdomen revealed dilated small bowel loops with a small outpouching in the distal ileum with a band like structure attached to it. In the CT, left sided patent IVC draining into the left renal vein was identified. Left external iliac vein was in continuity with the left IVC. Left internal iliac vein was draining into the right IVC. Exploratory laparotomy revealed a Meckel's diverticulum with a band identified as the vitelline remnant attached to its apex and inserting at the anterior abdominal wall near the umbilicus. Discussion. Meckel's diverticulum with vitelline bands, although rare, should be borne in mind in adult patients with intestinal obstruction. Identification of this anomaly can be difficult in imaging studies. Presence of double IVC should be mentioned in the imaging findings to prevent possible catastrophic complications during surgery. PMID:27843667

  3. Congenital abnormalities of the inferior vena cava presenting clinically in adolescent males.

    PubMed

    Halparin, Jessica; Monagle, Paul; Newall, Fiona

    2015-04-01

    Congenital anatomic abnormality of the inferior vena cava (IVC) is an important risk factor for the development of spontaneous proximal lower extremity deep vein thrombosis (DVT) in young adults. The incidence of DVT associated with congenital IVC anomalies in paediatric populations has not been described, and the implications of IVC anomalies for treatment and outcomes of DVT are unknown. This study reports a series of five adolescent males with spontaneous lower extremity DVTs and underlying congenital IVC abnormalities. Cases were identified by searching the institutional database of patients treated with anticoagulation for venous thromboembolism at a tertiary children's hospital. The demographics, clinical presentations, imaging findings, treatment courses, and outcomes are described. All cases occurred in males, and accounted for approximately twenty percent of adolescent males presenting with DVT. IVC abnormality is likely an under-recognized risk factor for DVT in this age group, and detailed vascular imaging should be pursued in adolescents with spontaneous proximal lower extremity DVT when initial ultrasonography does not delineate the proximal clot extent. Management requires individual risk-benefit assessment in the context of providing developmentally appropriate care. Further research is required to establish long-term outcomes and determine optimal treatment strategies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Prospective surveillance of phlebitis associated with peripheral intravenous catheters.

    PubMed

    Malach, Tal; Jerassy, Ziona; Rudensky, Bernard; Schlesinger, Yechiel; Broide, Etty; Olsha, Oded; Yinnon, Amos M; Raveh, David

    2006-06-01

    Guidelines have been published for prevention of phlebitis associated with peripheral intravenous catheters (IVC), but this complication continues to occur. We sought to determine the rate of phlebitis associated with peripheral IVCs to identify predictors for phlebitis and to isolate pathogenic bacteria from phlebitic catheter tips. Nine-point prevalence studies were conducted during the years 1996-2003 of all hospitalized patients with a peripheral IVC. During the last 3 surveys, conducted in 2003, phlebitic lines were removed, and, for each line, 1 to 2 nonphlebitic lines, in place for 48 to 72 hours, were removed and cultured as controls. In between these surveys, findings and guidelines for improvement were distributed to the staff. During these surveys, 40% +/- 8% of hospitalized patients had a peripheral IVC. The rate of peripheral IVC-associated phlebitis decreased from 12.7% (20/157) in 1998 to 2.6% (5/189) in 2003 (P < .01). Factors significantly associated with phlebitis included pain (P < .001), presence of the catheter for longer than 3 days (P < .05), and cleanliness of the dressing (P < .01). The rate of phlebitis associated with peripheral intravenous catheters decreased significantly throughout the study period. The identification of predictors for phlebitis and the dissemination of this information in an educational drive may have contributed to this improvement.

  5. Renal cell carcinoma with inferior vena cava thrombus extending to the right atrium diagnosed during pregnancy.

    PubMed

    Ghanney, Efe C; Cavallo, Jaime A; Levin, Matthew A; Reddy, Ramachandra; Bander, Jeffrey; Mella, Maria; Stone, Joanne; Schwartz, Myron; Haines, Kenneth; Gidwani, Umesh; Mehrazin, Reza

    2017-12-01

    Only one case of renal cell carcinoma (RCC) with inferior vena cava (IVC) tumor thrombus diagnosed and treated during pregnancy has been reported in the literature. In that report, the tumor thrombus extended to the infrahepatic IVC (level II tumor thrombus). In the present case, a 37-year-old woman with lupus anticoagulant antibodies was diagnosed with RCC and IVC tumor thrombus extending to the right atrium (level IV tumor thrombus) at 24 weeks of pregnancy. The fetus was safely delivered by cesarean section at 30 weeks of gestation. At 4 days later, an open right radical nephrectomy and IVC and right atrial thrombectomy were performed on cardiopulmonary bypass (CPB) once the patient's hemodynamic status had been optimized. Fetal and maternal concerns included the risk of a thromboembolic event (due to increased hypercoagulability from pregnancy, active malignancy, and lupus anticoagulant), intraoperative hemorrhage risk (due to extensive venous collaterals and anticoagulation), and fetal morbidity and mortality (due to fetal lung immaturity). Standardized guidelines for treatment of RCC with or without IVC tumor thrombus during pregnancy are unavailable due to the infrequency of such cases. Treatment decisions are therefore individualized and this case report may inform the management of future patients diagnosed with RCC with level IV tumor thrombus during pregnancy.

  6. Interlaminar and lateral excitatory amino acid connections in the striate cortex of monkey.

    PubMed

    Kisvarday, Z F; Cowey, A; Smith, A D; Somogyi, P

    1989-02-01

    The intrinsic excitatory amino acid pathways within the striate cortex of monkeys were studied by autoradiographic detection of retrogradely labeled somata following microinjections of D-3H-aspartate (D-3H-Asp) into different layers. The labeled amino acid was selectively accumulated by subpopulations of neurons and, to a small extent, by glial cells, the latter mainly in the supragranular layers. Immunocytochemical detection of neurons containing GABA showed that, apart from a few cells exclusively in layer I, GABAergic neurons do not accumulate D-3H-Asp. Several lines of evidence suggest that D-3H-Asp uptake occurred only at nerve terminals; thus, the pattern of perikaryal labeling allowed the delineation of interlaminar and lateral projections. Neurons in layer I probably project laterally, and layer I receives wide-ranging projections from layer IVB and layer V from cells up to 1300 microns laterally. Some neurons in layer II send a focused projection to lower layer VI. Some neurons in layers II/III project up to 1 mm laterally within their own layer, but relatively few neurons can be labeled in these projections. Similarly, in layers II/III few neurons can be retrogradely labeled from layers V and upper VI, and this projection is organized such that cells closer to the pia project deeper in layer V/VI. The connections of layer IVA could not be revealed separately because of the difficulty of confining injections to this thin sublamina. Neurons in layer IVB project up to 1300 microns within IVB itself. A small number of cells from IVB also project to layers III, IVC-alpha, V, and VI with much more restricted lateral spread. Neurons in upper IVC-alpha send axons to layer IVB with at least 600-800 microns lateral spread. Neurons in lower IVC-alpha/upper IVC-beta project to layer III with at least 300-500 microns lateral spread. The bottom 50-80 microns of layer IVC-beta contains neurons with a very focused projection, apparently exclusively to the layer III/IVA border region. Both layers IVC alpha and beta have rich connections within themselves, the beta sublayer having more restricted lateral connections. Some neurons in layer IVC-beta give a laterally restricted small input to layers IVC-alpha and IVB. Both IVC-alpha and -beta project to layers V and VI, and these projections are spread at least 400 microns laterally. Neurons in layer V project to all layers, but the projection to layers I-III and within layer V itself spread much further laterally than the projections to layers IV and VI.(ABSTRACT TRUNCATED AT 400 WORDS)

  7. Decitabine in Treating Patients With Metastatic Papillary Thyroid Cancer or Follicular Thyroid Cancer Unresponsive to Iodine I 131

    ClinicalTrials.gov

    2014-08-20

    Recurrent Thyroid Cancer; Stage IVA Follicular Thyroid Cancer; Stage IVA Papillary Thyroid Cancer; Stage IVB Follicular Thyroid Cancer; Stage IVB Papillary Thyroid Cancer; Stage IVC Follicular Thyroid Cancer; Stage IVC Papillary Thyroid Cancer

  8. Inferior Vena Cava Filter Limb Fracture with Embolization to the Right Ventricle.

    PubMed

    Jackson, Bradley S; Sepula, Mykel; Marx, Jared T; Cannon, Chad M

    2017-08-01

    Inferior vena cava (IVC) filter and filter limb embolization is a known phenomenon, with a prevalence of up to 25% for certain filter types. Most commonly, the site of embolization is to the heart. Point-of-care ultrasound is an easily accessible imaging modality that should be utilized when considering IVC filter complications. A 28-year-old woman with a history of metastatic sarcoma and IVC filter placement for deep venous thrombosis presented to the Emergency Department (ED) for chest pain. Chest radiography was reviewed and originally thought to have no abnormalities. Chest computed tomography angiography was negative for filling defects or foreign bodies. A possible foreign body in the heart was noted by a radiologist's over-read of the original chest radiograph. An echocardiogram done by Cardiology was negative for foreign bodies or other abnormalities. Next, an emergency physician performed a bedside echocardiogram, with focused attention to the right side of the heart. An echogenic foreign body was visualized in the right ventricle. The patient was subsequently taken to the cardiac catheterization laboratory, where fluoroscopic visualization of a limb wire of an IVC filter within the right ventricle was obtained. That foreign body was subsequently removed successfully, along with removal of the broken IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: This case report highlights the utility of point-of-care ultrasound in the work-up of a patient with an embolized IVC filter wire. Chest pain patients frequently receive point-of-care echocardiography in the ED, and these ultrasound findings should be recognized and used to guide further treatment and consultation. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Accuracy of Inferior Vena Cava Ultrasound for Predicting Dehydration in Children with Acute Diarrhea in Resource-Limited Settings.

    PubMed

    Modi, Payal; Glavis-Bloom, Justin; Nasrin, Sabiha; Guy, Allysia; Chowa, Erika P; Dvor, Nathan; Dworkis, Daniel A; Oh, Michael; Silvestri, David M; Strasberg, Stephen; Rege, Soham; Noble, Vicki E; Alam, Nur H; Levine, Adam C

    2016-01-01

    Although dehydration from diarrhea is a leading cause of morbidity and mortality in children under five, existing methods of assessing dehydration status in children have limited accuracy. To assess the accuracy of point-of-care ultrasound measurement of the aorta-to-IVC ratio as a predictor of dehydration in children. A prospective cohort study of children under five years with acute diarrhea was conducted in the rehydration unit of the International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b). Ultrasound measurements of aorta-to-IVC ratio and dehydrated weight were obtained on patient arrival. Percent weight change was monitored during rehydration to classify children as having "some dehydration" with weight change 3-9% or "severe dehydration" with weight change > 9%. Logistic regression analysis and Receiver-Operator Characteristic (ROC) curves were used to evaluate the accuracy of aorta-to-IVC ratio as a predictor of dehydration severity. 850 children were enrolled, of which 771 were included in the final analysis. Aorta to IVC ratio was a significant predictor of the percent dehydration in children with acute diarrhea, with each 1-point increase in the aorta to IVC ratio predicting a 1.1% increase in the percent dehydration of the child. However, the area under the ROC curve (0.60), sensitivity (67%), and specificity (49%), for predicting severe dehydration were all poor. Point-of-care ultrasound of the aorta-to-IVC ratio was statistically associated with volume status, but was not accurate enough to be used as an independent screening tool for dehydration in children under five years presenting with acute diarrhea in a resource-limited setting.

  10. Accuracy of Inferior Vena Cava Ultrasound for Predicting Dehydration in Children with Acute Diarrhea in Resource-Limited Settings

    PubMed Central

    Modi, Payal; Glavis-Bloom, Justin; Nasrin, Sabiha; Guy, Allysia; Rege, Soham; Noble, Vicki E.; Alam, Nur H.; Levine, Adam C.

    2016-01-01

    Introduction Although dehydration from diarrhea is a leading cause of morbidity and mortality in children under five, existing methods of assessing dehydration status in children have limited accuracy. Objective To assess the accuracy of point-of-care ultrasound measurement of the aorta-to-IVC ratio as a predictor of dehydration in children. Methods A prospective cohort study of children under five years with acute diarrhea was conducted in the rehydration unit of the International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b). Ultrasound measurements of aorta-to-IVC ratio and dehydrated weight were obtained on patient arrival. Percent weight change was monitored during rehydration to classify children as having “some dehydration” with weight change 3–9% or “severe dehydration” with weight change > 9%. Logistic regression analysis and Receiver-Operator Characteristic (ROC) curves were used to evaluate the accuracy of aorta-to-IVC ratio as a predictor of dehydration severity. Results 850 children were enrolled, of which 771 were included in the final analysis. Aorta to IVC ratio was a significant predictor of the percent dehydration in children with acute diarrhea, with each 1-point increase in the aorta to IVC ratio predicting a 1.1% increase in the percent dehydration of the child. However, the area under the ROC curve (0.60), sensitivity (67%), and specificity (49%), for predicting severe dehydration were all poor. Conclusions Point-of-care ultrasound of the aorta-to-IVC ratio was statistically associated with volume status, but was not accurate enough to be used as an independent screening tool for dehydration in children under five years presenting with acute diarrhea in a resource-limited setting. PMID:26766306

  11. Retrievable inferior vena cava filters can be placed and removed with a high degree of success: Initial experience.

    PubMed

    Cohoon, Kevin P; McBride, Joseph; Friese, Jeremy L; McPhail, Ian R

    2015-10-01

    Evaluate the success rate of retrievable inferior vena cava filter (IVC) removal in a tertiary care practice. Retrievable IVC filters became readily available in the United States following Food and Drug Administration approval in 2003, and their use has increased dramatically. They represent an attractive option for patients with contraindications to anticoagulation who may only need short-term protection against pulmonary embolism. All patients who had undergone placement of a retrievable IVC filter at Mayo Clinic between 2003 and 2005 were retrospectively reviewed to evaluate our initial experience with retrievable inferior vena cava filters at a large tertiary care center. During a three-year-period of time, Mayo Clinic, Rochester, MN placed 892 IVC filters of which 460 were retrievable. Of the 460 retrievable filters placed (249 Günther Tulip®, 207 Recovery®, and 4 OptEase®), retrieval was attempted in 223 (48.5%). Of 223 initial attempts, 196 (87.9%) were initially successful and 27 (12.1%) were unsuccessful. Of the 27 unsuccessful initial retrieval attempts, 23 (85.2%) were because of the presence of significant thrombus within the filter and 4 (14.8%) were because of tilting and strut perforation. Of the 23 filters containing significant thrombus, 9 (39.1%) were later retrieved after a period of anticoagulation and resolution of the thrombus. Retrievable IVC filters can be removed with a high degree of success. Approximately one in ten retrievable IVC filter removal attempts may fail initially, usually because of significant thrombus within the filter. This does not preclude possible removal at a later date. © 2015 Wiley Periodicals, Inc.

  12. Adjunctive Inferior Vena Cava Filter Placement for Acute Pulmonary Embolism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jha, V. M., E-mail: vjha@mfa.gwu.ed; Lee-Llacer, J.; Williams, J.

    Inferior vena cava (IVC) filters are sometimes placed as an adjunct to full anticoagulation in patients with significant pulmonary embolism (PE). We aimed to determine the prevalence of adjunctive IVC filter placement in individuals diagnosed with PE, as well as the effect of adjunctive filter placement on mortality in patients with right heart strain associated with PE. This was a retrospective study of patients with acute PE treated with full anticoagulation admitted to a single academic medical center. Information abstracted from patient charts included presence or absence of right heart strain and of deep-vein thrombosis, and whether or not anmore » IVC filter was placed. The endpoint was in-hospital mortality. Over 2.75 years, we found that 248 patients were diagnosed with acute PE, with an in-hospital mortality rate of 4.4%. The prevalence of adjunctive IVC filter placement was 13.3% (33 of 248), and the prevalence of documented right heart strain was 27.0% (67 of 248). In-hospital mortality was 10.2% in the non-filter-treated group (5 of 49), whereas there were no deaths in the filter-treated group (0 of 18); however, the difference was not statistically significant (P = 0.37). Both the presence of deep-vein thrombosis and of right heart strain increased the likelihood that an adjunctive IVC filter was placed (P < 0.0001 and P < 0.001, respectively). At our institution, patients were treated with IVC filters in addition to anticoagulation in 13.3% of cases of acute PE. Prospective studies or large clinical registries should be conducted to clarify whether this practice improves outcomes.« less

  13. The Optional VenaTech{sup Trade-Mark-Sign} Convertible{sup Trade-Mark-Sign} Vena Cava Filter: Experimental Study in Sheep

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le Blanche, Alain F., E-mail: le_blanche.alain@chu-amiens.fr; Ricco, Jean-Baptiste; Bonneau, Michel

    Purpose: Retrieval of optional caval filters may be impaired by filter tilting, migration, fracture, or embedding in the IVC wall. The goal of this experimental study was to evaluate a new optional filter, convertible by unlocking and removing the filter head. Methods: Forty-nine Pre-Alp sheep (average weight, 55 kg) were anesthetized. IVC was catheterized via the right femoral vein (n = 46) or via the internal jugular vein (n = 3) with a 12.9-F sheath. VenaTech{sup Trade-Mark-Sign} Convertible{sup Trade-Mark-Sign} IVC filters were inserted as either permanent filters (n = 14) or as filters to be converted. Conversion was immediately aftermore » deployment (n = 19) or delayed after 1, 3, or 6 months (n = 20). Filter delivery, deployment, and conversion with measurement of migration and tilting were evaluated by cavography. Incorporation of the filter's stabilizers and arms in the IVC wall was assessed by gross anatomy. Results: Delivery system insertion, filter release, and immediate conversion were successful in all cases. Delayed conversion was completed in all but one sheep, due to insufficient snare tension. Complimentary balloon-catheter inflation was required in 12 of 20 delayed conversions to achieve filter opening. In all 49 sheep, no thrombosis, migration, or significant tilting occurred. Within 4 weeks of conversion, the filter's stabilizers and arms were incorporated into the IVC wall. Upon removal, the filter head was free of intimal growth. Conclusions: The VenaTech{sup Trade-Mark-Sign} Convertible{sup Trade-Mark-Sign} optional IVC filter was successfully implanted in all sheep with no migration or tilting. Conversion at various dates by filter head removal was feasible in all but one case.« less

  14. Clinical outcome after intrahepatic venous stent placement for malignant inferior vena cava syndrome.

    PubMed

    Brountzos, Elias N; Binkert, Christoph A; Panagiotou, Irene E; Petersen, Bryan D; Timmermans, Hans; Lakin, Paul C

    2004-01-01

    We evaluated the clinical outcome of malignant inferior vena cava (IVC) syndrome after intrahepatic IVC stent placement by retrospective analysis of 50 consecutive patients (25 men, 25 women, age 32-83 years) with malignant IVC syndrome who were treated with intrahepatic stent placement. Gianturco-Rosch-Z (GRZ) stents (n = 45), and Wallstents (n = 5) were inserted. Clinical outcome was assessed from patients' records using a score based on leg swelling, scrotal/vulvar edema, ascites and anasarca before and after stent placement, as well as at last follow-up visit before death. Clinical follow-up was supplemented by duplex sonography in 36 patients. Inferior venocavography was performed in 5 patients prior to re- intervention. Follow-up time ranged from 1 to 932 days (mean 62 days). Mean pressure gradient in the IVC was reduced from 14 +/- 4.1 mmHg before to 2.9 +/- 3.2 mmHg after stent placement (p < 0.001). Four patients had stent occlusion, 2 of whom were successfully re-stented. Primary and secondary patency was 59% and 100%, respectively at 540 days. Immediate clinical data were available in 44 patients: 38 improved; 6 did not respond. Last follow-up visit data were available in 36 patients: 24 showed persistent symptom relief till death. All symptom scores were significantly improved after stent placement (p < 0.001) and with the exception of ascites, remained significantly improved (p < 0.05) until the last follow-up. Increased serum bilirubin was a common characteristic of clinical failures and recurrences. Intrahepatic IVC stent placement resulted in significant symptomatic relief in patients with malignant IVC syndrome. Palliation was effective even in patients with a very short life expectancy.

  15. Vena Cava Responsiveness to Controlled Isovolumetric Respiratory Efforts.

    PubMed

    Folino, Anna; Benzo, Marco; Pasquero, Paolo; Laguzzi, Andrea; Mesin, Luca; Messere, Alessandro; Porta, Massimo; Roatta, Silvestro

    2017-10-01

    Respirophasic variation of inferior vena cava (IVC) size is affected by large variability with spontaneous breathing. This study aims at characterizing the dependence of IVC size on controlled changes in intrathoracic pressure. Ten healthy subjects, in supine position, performed controlled isovolumetric respiratory efforts at functional residual capacity, attaining positive (5, 10, and 15 mmHg) and negative (-5, -10, and -15 mmHg) alveolar pressure levels. The isovolumetric constraint implies that equivalent changes are exhibited by alveolar and intrathoracic pressures during respiratory tasks. The IVC cross-sectional area equal to 2.88 ± 0.43 cm 2 at baseline (alveolar pressure = 0 mmHg) was progressively decreased by both expiratory and inspiratory efforts of increasing strength, with diaphragmatic efforts producing larger effects than thoracic ones: -55 ± 15% decrease, at +15 mmHg of alveolar pressure (P < .01), -80 ± 33 ± 12% at -15 mmHg diaphragmatic (P < .01), -33 ± 12% at -15 mmHg thoracic. Significant IVC changes in size (P < .01) and pulsatility (P < .05), along with non significant reduction in the response to respiratory efforts, were also observed during the first 30 minutes of supine rest, detecting an increase in vascular filling, and taking place after switching from the standing to the supine position. This study quantified the dependence of the IVC cross-sectional area on controlled intrathoracic pressure changes and evidenced the stronger influence of diaphragmatic over thoracic activity. Individual variability in thoracic/diaphragmatic respiratory pattern should be considered in the interpretation of the respirophasic modulations of IVC size. © 2017 by the American Institute of Ultrasound in Medicine.

  16. Influence of Compression Ratio on High Load Performance and Knock Behavior for Gasoline Port-Fuel Injection, Natural Gas Direct Injection and Blended Operation in a Spark Ignition Engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pamminger, Michael; Sevik, James; Scarcelli, Riccardo

    Natural Gas (NG) is an alternative fuel which has attracted a lot of attention recently, in particular in the US due to shale gas availability. The higher hydrogen-to-carbon (H/C) ratio, compared to gasoline, allows for decreasing carbon dioxide emissions throughout the entire engine map. Furthermore, the high knock resistance of NG allows increasing the efficiency at high engine loads compared to fuels with lower knock resistance. NG direct injection (DI) allows for fuel to be added after intake valve closing (IVC) resulting in an increase in power density compared to an injection before IVC. Steady-state engine tests were performed onmore » a single-cylinder research engine equipped with gasoline (E10) port-fuel injection (PFI) and NG DI to allow for in-cylinder blending of both fuels. Knock investigations were performed at two discrete compression ratios (CR), 10.5 and 12.5. Operating conditions span mid-load, wide-open-throttle and boosted conditions, depending on the knock response of the fuel blend. Blended operation was performed using E10 gasoline and NG. An additional gasoline type fuel (E85) with higher knock resistance than E10 was used as a high-octane reference fuel, since the octane rating of E10-NG fuel blends is unknown. Spark timing was varied at different loads under stoichiometric conditions in order to study the knock response as well as the effects on performance and efficiency. As anticipated, results suggest that the knock resistance can be increased significantly by increasing the NG amount. Comparing the engine operation with the least knock resistant fuel, E10 PFI, and the fuel blend with the highest knock resistance, 75% NG DI, shows an increase in indicated mean effective pressure of about 9 bar at CR 12.5. The usage of reference fuels with known knock characteristics allowed an assessment of knock characteristic of intermediate E10-NG blend levels. Mathematical correlations were developed allowing characterizing the occurrence of knocking combustion by using the Livengood-Wu knock integral. For most of the fueling strategies and operating conditions, the mathematical correlations show good agreement when compared to experimental data.« less

  17. Successful balloon dilatation for postoperative caval stenosis caused by primary venorrhaphy for traumatic retro-hepatic caval injury in a three-year-old child: Report of a case.

    PubMed

    Masui, Daisuke; Iinuma, Yasushi; Hirayama, Yutaka; Nitta, Kohju; Iida, Hisataka; Otani, Tetsuya; Yokoyama, Naoyuki; Sato, Seiichi; Numano, Fujito; Yagi, Minoru

    2015-09-01

    Inferior vena cava injuries are highly lethal. We experienced a case of retrohepatic inferior vena cava injury as a result of blunt trauma in a three-year-old female. Because the site of bleeding of the IVC was identified, we repaired it with running sutures. An attempt at primary repair resulted in postoperative narrowing of the vena cava. There was pressure gradient of the right atrium and inferior vena cava, and collateral circulation developed. Since it was also found that the haemodynamics was unstable, the child underwent another intervention before the stenosis of the IVC was fixed. To the best of our knowledge, there have been no previous reports of therapeutic radiological intervention for stenosis that developed after treatment of a traumatic IVC injury. The IVC in the present case recovered enough patency so that the collateral venous flow could be decreased after balloon dilatation angioplasty. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. First-line intra-arterial versus intravenous chemotherapy in unilateral sporadic group D retinoblastoma: evidence of better visual outcomes, ocular survival and shorter time to success with intra-arterial delivery from retrospective review of 20 years of treatment.

    PubMed

    Munier, Francis L; Mosimann, Pascal; Puccinelli, Francesco; Gaillard, Marie-Claire; Stathopoulos, Christina; Houghton, Susan; Bergin, Ciara; Beck-Popovic, Maja

    2017-08-01

    The introduction of intra-arterial chemotherapy (IAC) as salvage treatment has improved the prognosis for eye conservation in group D retinoblastoma. The aim of this study was to compare the outcomes of consecutive patients with advanced unilateral disease treated with either first-line intravenous chemotherapy (IVC) or first-line IAC. This is a retrospective mono-centric comparative review of consecutive patients. Sporadic unilateral retinoblastoma group D cases treated conservatively at Jules-Gonin Eye Hospital and CHUV between 1997 and 2014. From January 1997 to August 2008, IVC, combined with focal treatments, was the primary treatment approach. From September 2008 to October 2014, IAC replaced IVC as first-line therapy. 48 patients met the inclusion criteria, receiving only either IAC or IVC as primary treatment modality. Outcomes of 23 patients treated by IVC were compared with those of 25 treated by IAC; mean follow-up was 105.3 months (range 29.2-218.6) and 41.7 months (range 19.6-89.5), respectively. Treatment duration was significantly shorter in the IAC group (p<0.001). Ten eyes in the IVC group underwent enucleation. Recordable visual acuity of the salvaged eyes was significantly better in the IAC group (0.9 vs 1.4 logarithm of the minimum angle of resolution, p<0.01). No extraocular disease, metastases or long-term systemic complications were observed in either group. The difference in the time frame between treatment groups had an impact on the availability of intravitreal chemotherapy treatment. Despite this, the results reported here imply that eyes treated with first-line IAC will have shorter treatment period, better ocular survival and visual acuity than first-line IVC. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  19. Congenital portosystemic venous connections and other abdominal venous abnormalities in patients with polysplenia and functionally univentricular heart disease: a case series and literature review.

    PubMed

    McElhinney, Doff B; Marx, Gerald R; Newburger, Jane W

    2011-01-01

    Published case reports suggest that congenital portosystemic venous connections (PSVC) and other abdominal venous anomalies may be relatively frequent and potentially important in patients with polysplenia syndrome. Our objective was to investigate the frequency and range of portal and other abdominal systemic venous anomalies in patients with polysplenia and inferior vena cava (IVC) interruption who underwent a cavopulmonary anastomosis procedure at our center, and to review the published literature on this topic and the potential clinical importance of such anomalies. Retrospective cohort study and literature review were used. Among 77 patients with heterotaxy, univentricular heart disease, and IVC interruption who underwent a bidirectional Glenn and/or modified Fontan procedure, pulmonary arteriovenous malformations were diagnosed in 33 (43%). Bilateral superior vena cavas were present in 42 patients (55%). Despite inadequate imaging in many patients, a partial PSVC, dual IVCs, and/or renal vein anomalies were detected in 15 patients (19%). A PSVC formed by a tortuous vessel running from the systemic venous system to the extrahepatic portal vein was found in six patients (8%). Abdominal venous anomalies other than PSVC were documented in 13 patients (16%), including nine (12%) with some form of duplicated IVC system, with a large azygous vein continuing to the superior vena cava and a parallel, contralateral IVC of similar or smaller size, and seven with renal vein anomalies. In patients with a partial PSVC or a duplicate IVC that connected to the atrium, the abnormal connection allowed right-to-left shunting. PSVC and other abdominal venous anomalies may be clinically important but under-recognized in patients with IVC interruption and univentricular heart disease. In such patients, preoperative evaluation of the abdominal systemic venous system may be valuable. More data are necessary to determine whether there is a pathophysiologic connection between the polysplenia variant of heterotaxy, PSVC, and cavopulmonary anastomosis-associated pulmonary arteriovenous malformations. © 2011 Copyright the Authors. Congenital Heart Disease © 2011 Wiley Periodicals, Inc.

  20. Differences in Influenza Vaccination Coverage between Adult Immigrants and Italian Citizens at Risk for Influenza-Related Complications: A Cross-Sectional Study

    PubMed Central

    Fabiani, Massimo; Riccardo, Flavia; Di Napoli, Anteo; Gargiulo, Lidia; Declich, Silvia; Petrelli, Alessio

    2016-01-01

    Background Due to their increased vulnerability, immigrants are considered a priority group for communicable disease prevention and control in Europe. This study aims to compare influenza vaccination coverage (IVC) between regular immigrants and Italian citizens at risk for its complications and evaluate factors affecting differences. Methods Based on data collected by the National Institute of Statistics during a population-based cross-sectional survey conducted in Italy in 2012–2013, we analysed information on 42,048 adult residents (≥ 18 years) at risk for influenza-related complications and with free access to vaccination (elderly residents ≥ 65 years and residents with specific chronic diseases). We compared IVC between 885 regular immigrants and 41,163 Italian citizens using log-binomial models and stratifying immigrants by area of origin and length of stay in Italy (recent: < 10 years; long-term: ≥ 10 years). Results IVC among all immigrants was 16.9% compared to 40.2% among Italian citizens (vaccination coverage ratio (VCR) = 0.42, 95% confidence interval (CI): 0.36–0.49). Adjusting for sex, age and area of residence, this difference was greatly reduced but remained statistically significant (VCR = 0.71, 95 CI: 0.61–0.81). Further adjustment for socio-economic factors (education, occupation, family composition and economic status) and a composite indicator of health-services utilization did not affect the difference (VCR = 0.78, 95% CI: 0.68–0.90). However, after adjustments, only long-term immigrants from Africa (VCR = 0.49, 95% CI: 0.28–0.85) and recent immigrants (VCR = 0.58, 95% CI: 0.43–0.78) showed a significantly different IVC compared to Italian citizens. Conclusions Differences in demographic characteristics, socio-economic conditions and health-services utilization explained the reduced IVC in most long-term immigrants compared to Italian citizens. By contrast, these differences did not explain the reduced IVC in long-term immigrants from Africa and recent immigrants. This suggests that IVC in these sub-groups is affected by other informal barriers (e.g., cultural and linguistic) that need to be investigated to promote effective immunization access strategies. PMID:27832186

  1. Cardiac transplantation in situs inversus: two cases reports.

    PubMed

    Chang, Y L; Wei, J; Chang, C-Y; Chuang, Y-C; Sue, S-H

    2008-10-01

    The challenge of heart transplantation in patients with situs inversus is reconstruction of the systemic venous return. Herein we have presented 2 cases of complex congenital heart disease with atriovisceral situs inversus. Both of the patients shared many common cardiac anomalies, such as a single ventricle, a single AV valve with severe regurgitation, and severe pulmonary stenosis. We completed the venous connection in 2 different ways. In the first case, the donor inferior vena cava (IVC) was anastomosed to the recipient left-sided IVC directly, making the heart slightly counterclockwise rotated. In the second case, the IVC venous reconnection was accomplished by a composite conduit made of recipient right atrium.

  2. Sunitinib in Treating Patients With Thyroid Cancer That Did Not Respond to Iodine I 131 and Cannot Be Removed by Surgery

    ClinicalTrials.gov

    2017-08-18

    Recurrent Thyroid Gland Carcinoma; Stage III Thyroid Gland Follicular Carcinoma; Stage III Thyroid Gland Medullary Carcinoma; Stage IV Thyroid Gland Follicular Carcinoma; Stage IV Thyroid Gland Medullary Carcinoma; Stage IV Thyroid Gland Papillary Carcinoma; Stage IVA Thyroid Gland Follicular Carcinoma; Stage IVA Thyroid Gland Medullary Carcinoma; Stage IVA Thyroid Gland Papillary Carcinoma; Stage IVB Thyroid Gland Follicular Carcinoma; Stage IVB Thyroid Gland Medullary Carcinoma; Stage IVB Thyroid Gland Papillary Carcinoma; Stage IVC Thyroid Gland Follicular Carcinoma; Stage IVC Thyroid Gland Medullary Carcinoma; Stage IVC Thyroid Gland Papillary Carcinoma; Thyroid Gland Oncocytic Follicular Carcinoma

  3. Prognostic significance of dilated inferior vena cava in advanced decompensated heart failure.

    PubMed

    Lee, Hsin-Fu; Hsu, Lung-An; Chang, Chi-Jen; Chan, Yi-Hsin; Wang, Chun-Li; Ho, Wan-Jing; Chu, Pao-Hsien

    2014-10-01

    Dilated inferior vena cava (IVC) is prevalent among patients with heart failure (HF), but whether its presence predicts worsening renal function (WRF) or adverse outcomes is unclear. This cohort study analyzed patients with left ventricular ejection fraction <40 % and repeated hospitalizations (≥2 times) for HF between August 2009 and August 2011. The study endpoints were death and HF re-hospitalization. Among baseline parameters, IVC diameter was the most powerful predictor for the development of WRF (area under the curve = 0.795, cut-off value = 20.5 mm). During the 2-year follow-up, 36 patients (49 %) were re-hospitalized for HF and 14 patients (19 %) died. The event rates were significantly greater in the WRF group than in the non-WRF group (71 vs. 30 %, P < 0.001 for HF re-hospitalization; 29 vs. 10 %, P = 0.03 for death). In Cox regression model, the risk of combined end-points was increased in patients with aging, elevated blood urine nitrogen, IVC >21 mm, and WRF. When adjusted for confounding factors, IVC >21 mm [hazard ratio (HR) 3.73, 95 % confidence interval (CI) 1.66-8.34] and WRF (HR 2.68, 95 % CI 1.07-6.75) were significant predictors for adverse outcomes. In patients with advanced decompensated HF, dilated IVC (>21 mm) predicted the development of WRF and could be a predictor for adverse outcomes.

  4. Should we isolate human preantral follicles before or after cryopreservation of ovarian tissue?

    PubMed

    Vanacker, Julie; Luyckx, Valérie; Amorim, Christiani; Dolmans, Marie-Madeleine; Van Langendonckt, Anne; Donnez, Jacques; Camboni, Alessandra

    2013-04-01

    To evaluate the survival and growth potential of human preantral follicles isolated before and after cryopreservation. Pilot study. Gynecology research unit in a university hospital. Six women aged 27 to 32 years. Six ovarian biopsy samples were cut into two equal parts, half subjected to slow-freezing followed by follicle isolation (cryo-iso group) and alginate-matrigel embedding, and half immediately processed for follicle isolation and alginate-matrigel embedding followed by slow-freezing (iso-cryo group) or used as fresh controls (fresh group). Follicle number, viability, diameter, and morphology. After 1,134 preantral follicles had been isolated from fresh biopsy samples and 1,132 from frozen specimens, the three groups were compared before and after 7 days of in vitro culture (IVC) in alginate-matrigel beads. No statistically significant differences in viability were found between the three groups before or after IVC, but follicle diameter increased in all three groups after IVC. Morphology analysis revealed well-preserved follicles in both the iso-cryo and cryo-iso groups after IVC. Human preantral follicles can be successfully cryopreserved before or after isolation without impairing their ability to survive and grow in vitro. This could lead to development of new protocols for follicle cryopreservation, IVC, and grafting in clinical and research settings for fertility preservation. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  5. Thromboembolic Risk of Endovascular Intervention for Lower Extremity Deep Venous Thrombosis.

    PubMed

    Lindsey, Philip; Echeverria, Angela; Poi, Mun J; Matos, Jesus; Bechara, Carlos F; Cheung, Mathew; Lin, Peter H

    2018-05-01

    This study evaluated the risk of thromboembolism during endovascular interventions in patients with symptomatic lower extremity deep vein thrombosis (DVT) METHODS: Clinical records of all patients who underwent endovascular interventions for symptomatic lower extremity DVT from 2001 to 2017 were retrospectively analyzed using a prospectively maintained database. Only patients who received an inferior vena cava (IVC) filter were included in the analysis. Trapped intrafilter thrombus was assessed for procedure-related thromboembolism. Clinical outcomes of thrombus management and thromboembolism risk were analyzed. A total 172 patients (mean age 57.4 years, 98 females) who underwent 174 endovascular DVT interventions were included in the analysis. Treatment strategies included thrombolytic therapy (64%), mechanical thrombectomy (n = 86%), pharmacomechanical thrombolysis (51%), balloon angioplasty (98%), and stent placement (28%). Thrombectomy device used included AngioJet (56%), Trellis (19%), and Aspire (11%). Trapped IVC filter thrombus was identified in 58 patients (38%) based on the IVC venogram. No patient developed clinically evident pulmonary embolism (PE). IVC filter retrieval was performed in 98 patients (56%, mean 11.8 months after implantation). Multivariate analysis showed that iliac vein occlusion (P = 0.04) was predictive for procedure-related thromboembolism. Iliac vein thrombotic occlusion is associated with an increased thromboembolic risk in DVT intervention. Retrievable IVC filter should be considered when performing percutaneous thrombectomy in patients with iliac venous occlusion to prevent PE. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Erlotinib, Docetaxel, and Radiation Therapy in Treating Patients With Locally Advanced Head and Neck Cancer

    ClinicalTrials.gov

    2014-06-05

    Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer; Untreated Metastatic Squamous Neck Cancer With Occult Primary

  7. Pazopanib Hydrochloride in Treating Patients With Advanced Thyroid Cancer

    ClinicalTrials.gov

    2018-05-08

    Recurrent Thyroid Gland Carcinoma; Stage III Differentiated Thyroid Gland Carcinoma AJCC v7; Stage III Thyroid Gland Medullary Carcinoma AJCC v7; Stage IVA Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVA Thyroid Gland Medullary Carcinoma AJCC v7; Stage IVA Thyroid Gland Undifferentiated (Anaplastic) Carcinoma AJCC v7; Stage IVB Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVB Thyroid Gland Medullary Carcinoma AJCC v7; Stage IVB Thyroid Gland Undifferentiated (Anaplastic) Carcinoma AJCC v7; Stage IVC Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVC Thyroid Gland Medullary Carcinoma AJCC v7; Stage IVC Thyroid Gland Undifferentiated (Anaplastic) Carcinoma AJCC v7; Thyroglobulin Antibody Negative; Thyroid Gland Undifferentiated (Anaplastic) Carcinoma

  8. Management of acute lower extremity deep venous thrombosis in a patient with duplicated inferior vena cava and contraindication to anticoagulation: case and review of the literature

    PubMed Central

    Patel, Shrinil; Cheema, Anmol; Karawadia, Tejas; Carson, Michael

    2018-01-01

    Duplication of the inferior vena cava (DIVC) is an uncommon embryological anatomic phenomenon. We report a 63-year-old woman with extensive right leg deep vein thrombosis who required an IVC filter due to contraindications for anticoagulation, but was found to have DIVC which required the placement of two IVC filters with good result. This report will review and summarise past reports of DIVC management to provide a guide for future clinicians, and review the embryological development, diagnosis and IVC filter placement options as they are based on the type of anatomic malformation encountered. PMID:29866665

  9. Safe and effective treatment of early suprahepatic inferior vena caval outflow compromise following orthotopic liver transplantation using percutaneous transluminal angioplasty and stent placement.

    PubMed

    Tasse, Jordan; Borge, Marc; Pierce, Kenneth; Brems, John

    2011-01-01

    To describe the safety and efficacy of percutaneous transluminal angioplasty and stent placement in patients presenting with suprahepatic inferior vena cava (IVC) outflow compromise in the early postoperative period following orthotopic liver transplantation. Between October 2002 and April 2009, 3 patients presented with IVC outflow compromise in the first 2 months following orthotopic liver transplantation. All 3 underwent percutaneous transluminal angioplasty and stent placement without complication and showed significant clinical improvement at short and intermediate term follow-up. Percutaneous transluminal angioplasty and Gianturco stent placement is a safe and effective treatment for IVC outflow compromise in the early postoperative period following orthotopic liver transplantation.

  10. Iodine I 131 and Pazopanib Hydrochloride in Treating Patients With Recurrent and/or Metastatic Thyroid Cancer Previously Treated With Iodine I 131 That Cannot Be Removed By Surgery

    ClinicalTrials.gov

    2015-11-04

    Recurrent Thyroid Cancer; Stage IVA Follicular Thyroid Cancer; Stage IVA Papillary Thyroid Cancer; Stage IVB Follicular Thyroid Cancer; Stage IVB Papillary Thyroid Cancer; Stage IVC Follicular Thyroid Cancer; Stage IVC Papillary Thyroid Cancer

  11. ESEA Title IV-C Innovation Administration Manual for South Carolina.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia. Office of Federal Programs.

    The intent of Title IV-C of the Elementary and Secondary Education Act (the Education Amendments of 1974) is to establish innovative and exemplary projects that provide creative or imaginative solutions to problems in the areas of supplementary centers and services, health and nutritional demonstrations, and dropout prevention. The purposes of…

  12. Trace Element Data help Understanding the Origin of Lake Bosumtwi Crater Related Glass (Ivory Coast Tektites, Microtektites, Fall-Back Particles, Suevite Glass)

    NASA Astrophysics Data System (ADS)

    Deutsch, A.; Langenhorst, F.; Berndt, J.

    2015-09-01

    We report for the four internally rather homogeneous groups of glass (IVC, IVC-MT, BOT 12 [suevite], FBG) concentrations of major and 42 minor elements (in-situ data with LA-ICP-MS) as well as Sr-Nd, and DEGAS data.

  13. Disintegration of the 'waterfall phenomenon' in the inferior vena cava due to right heart failure.

    PubMed

    Kira, S; Dambara, T; Mieno, T; Tamaki, S; Natori, H

    1996-03-01

    The concept of the waterfall phenomenon in Zone 2 in the pulmonary vasculature is well known from West's lung model. It is believed that the flow through this zone is determined by the pressure difference between the pulmonary artery and alveoli, and the left atrial pressure is not transmissible to the alveolar capillaries. However, it is impossible to see whether alveolar capillaries are really displaying the waterfall phenomenon or not. In this review, the interrelation between the flow and geometry of the alveolar capillaries in the waterfall phenomenon is analyzed based on physiological studies using a model system and isolated lung lobe experiments. Further, extending the concept to the analysis of ventilatory changes of the inferior vena cava (IVC) configuration, it is ascertained that the waterfall phenomenon normally occurs in the IVC during inspiration just before it enters the thorax and the waterfall phenomenon in the IVC disintegrates with elevation of the central venous pressure. Because these configurations of the IVC in normal and abnormal conditions are visible with ultrasonography, the technique is very useful as a noninvasive approach to diagnose right heart failure.

  14. Thrombus just beneath a retrievable inferior vena cava filter in a pregnant woman with deep vein thrombosis: its removal requiring catheter thrombus fragmentation with fibrinolysis.

    PubMed

    Horie, Kenji; Suzuki, Hirotada; Ohkuchi, Akihide; Matsubara, Shigeki; Ikemoto, Tomokazu; Suzuki, Mitsuaki

    2014-02-01

    Recently, transient inferior vena cava (IVC) filters have been employed to protect against pulmonary embolism (PE) in pregnant women with deep vein thrombosis. A 34-year-old primiparous Japanese woman with a history of myomectomy was diagnosed with deep vein thrombosis by ultrasound at 27 weeks of gestation. Unfractionated heparin was administered, which soon ameliorated swelling in the right thigh. A transient IVC filter was implanted just before cesarean section. An enhanced computed tomography scan 2 days after cesarean section revealed a wide thrombus just distal to the filter. We performed catheter thrombus fragmentation with fibrinolysis just before the removal of the IVC filter, resulting in re-canalization of blood flow. No significant PE occurred. Although a transient IVC filter may work well for the prophylaxis of PE during labor and delivery, catheter fragmentation with fibrinolysis may become necessary at removal of the filter. © 2013 The Authors. Journal of Obstetrics and Gynaecology Research © 2013 Japan Society of Obstetrics and Gynecology.

  15. Retrieval of Tip-embedded Inferior Vena Cava Filters by Using the Endobronchial Forceps Technique: Experience at a Single Institution.

    PubMed

    Stavropoulos, S William; Ge, Benjamin H; Mondschein, Jeffrey I; Shlansky-Goldberg, Richard D; Sudheendra, Deepak; Trerotola, Scott O

    2015-06-01

    To evaluate the use of endobronchial forceps to retrieve tip-embedded inferior vena cava (IVC) filters. This institutional review board-approved, HIPAA-compliant retrospective study included 114 patients who presented with tip-embedded IVC filters for removal from January 2005 to April 2014. The included patients consisted of 77 women and 37 men with a mean age of 43 years (range, 18-79 years). Filters were identified as tip embedded by using rotational venography. Rigid bronchoscopy forceps were used to dissect the tip or hook of the filter from the wall of the IVC. The filter was then removed through the sheath by using the endobronchial forceps. Statistical analysis entailed calculating percentages, ranges, and means. The endobronchial forceps technique was used to successfully retrieve 109 of 114 (96%) tip-embedded IVC filters on an intention-to-treat basis. Five failures occurred in four patients in whom the technique was attempted but failed and one patient in whom retrieval was not attempted. Filters were in place for a mean of 465 days (range, 31-2976 days). The filters in this study included 10 Recovery, 33 G2, eight G2X, 11 Eclipse, one OptEase, six Option, 13 Günther Tulip, one ALN, and 31 Celect filters. Three minor complications and one major complication occurred, with no permanent sequelae. The endobronchial forceps technique can be safely used to remove tip-embedded IVC filters. © RSNA, 2014.

  16. Inferior vena cava filters in trauma patients: efficacy, morbidity, and retrievability.

    PubMed

    Smoot, Rory L; Koch, Cody A; Heller, Stephanie F; Sabater, Enrique A; Cullinane, Daniel C; Bannon, Michael P; Thomsen, Kristine M; Harmsen, William S; Baerga-Varela, Yvonne; Schiller, Henry J

    2010-04-01

    Thromboembolic events are potentially devastating sources of morbidity in trauma patients. With increasing experience and the introduction of retrievable devices, there has been a renewed interest in inferior vena cava (IVC) filters in trauma patients. The records for consecutive trauma patients undergoing IVC filter placement during the years 2001 to 2005 were reviewed, and clinical, demographic, and procedural data were evaluated for associations with thromboembolic events and device complications. During the study years, 226 trauma patients had IVC filters inserted, and 140 of these patients (62%) had retrievable IVC filters placed. Six patients (3%) had a pulmonary embolism with the filter in place, and two patients (1%) had a pulmonary embolism after filter removal. The most common complication was thrombosis in 27 patients (12%), with clinically significant thrombus occurring in 15 patients (7%). There was no association between the type of filter (permanent or retrievable) or the brand of retrievable filter and thrombosis. Specific risk factors for thrombosis could not be identified. Retrievable filters were successfully removed in 61% of patients with retrievable filters. Technical success rate was 97% in those patients who underwent attempted removal. Removal was completed at a median of 21 days (range, 2-292 days). Retrievable IVC filters in trauma patients are safe, but complications do occur with thrombosis being the most common. Retrieval has a high technical success rate when attempted. However, a significant number of trauma patients are lost to follow-up and this may impact the utilization of retrievable filters in this patient population.

  17. Cardiac variation of inferior vena cava: new concept in the evaluation of intravascular blood volume.

    PubMed

    Nakamura, Kensuke; Tomida, Makoto; Ando, Takehiro; Sen, Kon; Inokuchi, Ryota; Kobayashi, Etsuko; Nakajima, Susumu; Sakuma, Ichiro; Yahagi, Naoki

    2013-07-01

    Evaluation of the intravascular blood volume is an important assessment in emergency and critical care medicine. Measurement of the inferior vena cava (IVC) respiratory variation by ultrasound echography is useful, but it entails subjective problems. We have hypothesized that IVC cardiac variation is also correlated with intravascular blood volume and analyzed it automatically using computer software of two kinds, later comparing the results. Snakes, software to track boundaries by curve line continuity, and template matching software were incorporated into a computer with an ultrasound machine to track the short-axis view of IVC automatically and analyze it with approximation by ellipse. Eight healthy volunteers with temporary mild hypovolemia underwent echography before and after passive leg raising and while wearing medical anti-shock trousers. IVC cardiac variation was visually decreased by both leg raising and medical anti-shock trousers. The collapse index (maximum - minimum/maximum) of area during three cardiac beats was decreased showing a good relationship to fluid load simulations; 0.24 ± 0.03 at baseline versus 0.11 ± 0.01 with leg raising and 0.12 ± 0.01 with medical anti-shock trousers. In conclusion, IVC cardiac variation has the potential to provide an evaluation of water volume. It presents some advantages in mechanical analysis over respiratory variation. At the very least, we need to exercise some caution with cardiac variation when evaluating respiratory variation.

  18. Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bozlar, Ugur; Edmunds, J. Stewart; Turba, Ulku C.

    The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavographymore » detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the caval lumen detected on 3-D CV that were not detected on sCV (p < 0.001). Filter apex tilt detection differed significantly (p < 0.001) between sCV and 3-D CV, with 3-D CV being more accurate. The filter apex abutted the IVC wall in 10 patients (33%) on 3-D CV, but this was diagnosed in only 3 patients (10%) with sCV. Thrombus was detected in 8 patients (27%), 1 thrombus of which was seen only on 3-D CV, and treatment was changed in this patient because of thrombus size. Mean effective radiation doses for 3-D CV were approximately two times higher than for sCV (1.68 vs. 0.86 mSv), whereas skin doses were three times lower (12.87 vs. 35.86 mGy). Compared with sCV, performing 3-D CV before optional IVC filter retrieval has the potential to improve assessment of filter arms or legs projecting beyond the caval lumen, filter orientation, and thrombus burden.« less

  19. Expression of genes responsible for cell morphogenesis involved in differentiation in porcine buccal pouch mucosal cells during long-term primary culture and real-time proliferation in vitro.

    PubMed

    Dyszkiewicz-Konwińska, M; Bryja, A; Jopek, K; Budna, J; Khozmi, R; Jeseta, M; Bukowska, D; Antosik, P; Bruska, M; Nowicki, M; Zabel, M; Kempisty, B

    2017-01-01

    Recently, using experimental animal model, we demonstrated that porcine buccal pouch mucosal cells reflect increased proliferation capability during primary cultivation in vitro. Although the histological structure and morphogenesis in oral cavity is well recognized, the molecular mechanisms which regulate this process still need further investigation. This study was aimed to analyze the molecular marker expression profile involved in morphogenesis and differentiation capacity of porcine buccal pouch mucosal cells during their long-term primary cultivation in vitro. The experiment was performed on buccal pouch mucosal cells isolated from 80 pubertal crossbred Landrace gilts. After collection, the cells were treated enzymatically and transferred into a primary in vitro culture (IVC) system and cultured for 30 days. The cells were collected for RNA isolation after 7, 15 and 30 days of IVC and were checked for their real-time proliferative status using the RTCA system. We found an increased expression of FN1 and SOX9 genes when calculated against ACTB after 7, and 30 days of IVC, (P less than 0.01, P less than 0.001, respectively). The CXCL12 mRNA was down-regulated after 7, 15 and 30 days of IVC, but not statistically significant. Similar expression profile was observed when calculated against HPRT, however, DAB2 was found to be higher expressed at day 15 of IVC, (P less than 0.05). The cell index measured during real-time cell proliferation was substantially increased between 96 h and 147h of IVC and reached the log phase. Since FN1 and SOX9 revealed significant increase of expression after long-term culture in vitro, it is suggested that expression of these differentiation and stemness genes is accompanied by cell proliferation. Moreover, FN1 and SOX9 might be recognized as new markers of buccal pouch mucosal cell proliferation and differentiation in pigs in in vitro primary culture model.

  20. Entolimod in Treating Patients With Stage III-IV Squamous Cell Head and Neck Cancer Receiving Cisplatin and Radiation Therapy

    ClinicalTrials.gov

    2013-12-10

    Mucositis; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer

  1. Residual tumor size and IGCCCG risk classification predict additional vascular procedures in patients with germ cell tumors and residual tumor resection: a multicenter analysis of the German Testicular Cancer Study Group.

    PubMed

    Winter, Christian; Pfister, David; Busch, Jonas; Bingöl, Cigdem; Ranft, Ulrich; Schrader, Mark; Dieckmann, Klaus-Peter; Heidenreich, Axel; Albers, Peter

    2012-02-01

    Residual tumor resection (RTR) after chemotherapy in patients with advanced germ cell tumors (GCT) is an important part of the multimodal treatment. To provide a complete resection of residual tumor, additional surgical procedures are sometimes necessary. In particular, additional vascular interventions are high-risk procedures that require multidisciplinary planning and adequate resources to optimize outcome. The aim was to identify parameters that predict additional vascular procedures during RTR in GCT patients. A retrospective analysis was performed in 402 GCT patients who underwent 414 RTRs in 9 German Testicular Cancer Study Group (GTCSG) centers. Overall, 339 of 414 RTRs were evaluable with complete perioperative data sets. The RTR database was queried for additional vascular procedures (inferior vena cava [IVC] interventions, aortic prosthesis) and correlated to International Germ Cell Cancer Collaborative Group (IGCCCG) classification and residual tumor volume. In 40 RTRs, major vascular procedures (23 IVC resections with or without prosthesis, 11 partial IVC resections, and 6 aortic prostheses) were performed. In univariate analysis, the necessity of IVC intervention was significantly correlated with IGCCCG (14.1% intermediate/poor vs 4.8% good; p=0.0047) and residual tumor size (3.7% size < 5 cm vs 17.9% size ≥ 5 cm; p < 0.0001). In multivariate analysis, IVC intervention was significantly associated with residual tumor size ≥ 5 cm (odds ratio [OR]: 4.61; p=0.0007). In a predictive model combining residual tumor size and IGCCCG classification, every fifth patient (20.4%) with a residual tumor size ≥ 5 cm and intermediate or poor prognosis needed an IVC intervention during RTR. The need for an aortic prosthesis showed no correlation to either IGCCCG (p=0.1811) or tumor size (p=0.0651). The necessity for IVC intervention during RTR is correlated to residual tumor size and initial IGCCCG classification. Patients with high-volume residual tumors and intermediate or poor risk features must initially be identified as high-risk patients for vascular procedures and therefore should be referred to specialized surgical centers with the ad hoc possibility of vascular interventions. Copyright © 2011 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  2. Talactoferrin in Treating Patients With Relapsed or Refractory Non-Small Cell Lung Cancer or Squamous Cell Head and Neck Cancer

    ClinicalTrials.gov

    2016-07-30

    Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Salivary Gland Squamous Cell Carcinoma; Stage III Salivary Gland Cancer; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Non-small Cell Lung Cancer; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer

  3. Association between expression of cumulus expansion markers and real-time proliferation of porcine follicular granulosa cells in a primary cell culture model.

    PubMed

    Ciesiółka, S; Budna, J; Bryja, A; Kranc, W; Chachuła, A; Dyszkiewicz-Konwińska, M; Piotrowska, H; Bukowska, D; Antosik, P; Bruska, M; Brüssow, K P; Nowicki, M; Zabel, M; Kempisty, B

    2016-01-01

    Folliculogenesis is a compound process that involves both ovarian follicle growth and oocyte development, which is tightly attached to the follicular wall. During this process, cells that form the follicle structure undergo substantial morphological and molecular modifications that finally lead to differentiation and specialization of ovarian follicular cells. The differentiation of ovarian cells encompasses formation of follicle, which is composed of theca (TCs), mural granulosa (GCs), and cumulus cells (CCs). It was previously hypothesized that GCs and CCs represent undifferentiated and highly specialized follicular cells, respectively, which may have similar primordial cell origins. In this study, we investigated the expression pattern of cumulus expansion markers such as COX2, HAS2, PTX3, and TSG6 in porcine GCs during short-term, in vitro culture. We hypothesized that these genes may display an important function in GCs in relation to cellular real-time proliferation. The expression pattern of COX2, HAS2, PTX3, and TSG6 was evaluated after using RT-qPCR in relation to confocal microscopy observations of protein expression and distribution during real-time proliferation of porcine follicular GCs. The COX2 and HAS2 mRNAs were highly expressed after 120 h of in vitro culture (IVC), whereas PTX3 and TSG6 mRNAs were increased during the first 24-48 h of IVC (P less than 0.001, P less than 0.01). Conversely, all of the encoded proteins were highly expressed after 144-168 h of IVC as compared to other culture periods (P less than 0.001, P less than 0.01). When analyzing the realtime proliferation of GCs in vitro, we observed a logarithmic increase of cell proliferation between 0 h and 120 h of IVC. However, after 120-168 h of IVC, the cells reached the lag phase of proliferation. Since it is well accepted that porcine GCs undergo luteinization shortly after 24-48 h of IVC, the expression pattern of investigated genes indicated that Cox2 and Has2 are independent from the LH surge, but their increased levels may be upregulated by cell proliferation in vitro. Moreover, higher expression of PTX3 and TSG6 during first 24 h and/or 48 h of IVC suggested that their levels are accompanied by porcine GCs luteinization process.

  4. Lenalidomide and Cetuximab in Treating Patients With Advanced Colorectal Cancer or Head and Neck Cancer

    ClinicalTrials.gov

    2018-05-23

    Recurrent Colon Carcinoma; Recurrent Hypopharyngeal Squamous Cell Carcinoma; Recurrent Laryngeal Squamous Cell Carcinoma; Recurrent Laryngeal Verrucous Carcinoma; Recurrent Lip and Oral Cavity Squamous Cell Carcinoma; Recurrent Metastatic Squamous Cell Carcinoma in the Neck With Occult Primary; Recurrent Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Recurrent Nasopharyngeal Keratinizing Squamous Cell Carcinoma; Recurrent Oral Cavity Verrucous Carcinoma; Recurrent Oropharyngeal Squamous Cell Carcinoma; Recurrent Rectal Carcinoma; Recurrent Salivary Gland Carcinoma; Salivary Gland Squamous Cell Carcinoma; Squamous Cell Carcinoma Metastatic in the Neck With Occult Primary; Stage IV Hypopharyngeal Squamous Cell Carcinoma AJCC v7; Stage IV Nasopharyngeal Keratinizing Squamous Cell Carcinoma AJCC v7; Stage IVA Colon Cancer AJCC v7; Stage IVA Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVA Laryngeal Verrucous Carcinoma AJCC v7; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVA Major Salivary Gland Cancer AJCC v7; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVA Oral Cavity Cancer AJCC v6 and v7; Stage IVA Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVA Rectal Cancer AJCC v7; Stage IVB Colon Cancer AJCC v7; Stage IVB Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Laryngeal Verrucous Carcinoma AJCC v7; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVB Major Salivary Gland Cancer AJCC v7; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVB Oral Cavity Cancer AJCC v6 and v7; Stage IVB Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Rectal Cancer AJCC v7; Stage IVC Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVC Laryngeal Verrucous Carcinoma AJCC v7; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVC Major Salivary Gland Cancer AJCC v7; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVC Oral Cavity Cancer AJCC v6 and v7; Stage IVC Oropharyngeal Squamous Cell Carcinoma AJCC v7; Tongue Carcinoma; Untreated Metastatic Squamous Cell Carcinoma to Neck With Occult Primary

  5. Numerical model of spray combustion in a single cylinder diesel engine

    NASA Astrophysics Data System (ADS)

    Acampora, Luigi; Sequino, Luigi; Nigro, Giancarlo; Continillo, Gaetano; Vaglieco, Bianca Maria

    2017-11-01

    A numerical model is developed for predicting the pressure cycle from Intake Valve Closing (IVC) to the Exhaust Valve Opening (EVO) events. The model is based on a modified one-dimensional (1D) Musculus and Kattke spray model, coupled with a zero-dimensional (0D) non-adiabatic transient Fed-Batch reactor model. The 1D spray model provides an estimate of the fuel evaporation rate during the injection phenomenon, as a function of time. The 0D Fed-Batch reactor model describes combustion. The main goal of adopting a 0D (perfectly stirred) model is to use highly detailed reaction mechanisms for Diesel fuel combustion in air, while keeping the computational cost as low as possible. The proposed model is validated by comparing its predictions with experimental data of pressure obtained from an optical single cylinder Diesel engine.

  6. Robotic inferior vena cava surgery.

    PubMed

    Davila, Victor J; Velazco, Cristine S; Stone, William M; Fowl, Richard J; Abdul-Muhsin, Haidar M; Castle, Erik P; Money, Samuel R

    2017-03-01

    Inferior vena cava (IVC) surgery is uncommon and has traditionally been performed through open surgical approaches. Renal cell carcinoma with IVC extension generally requires vena cavotomy and reconstruction. Open removal of malpositioned IVC filters (IVCF) is occasionally required after endovascular retrieval attempts have failed. As our experience with robotic surgery has advanced, we have applied this technology to surgery of the IVC. We reviewed our institution's experience with robotic surgical procedures involving the IVC to determine its safety and efficacy. All patients undergoing robotic surgery that included cavotomy and repair from 2011 to 2014 were retrospectively reviewed. Data were obtained detailing preoperative demographics, operative details, and postoperative morbidity and mortality. Ten patients (6 men) underwent robotic vena caval procedures at our institution. Seven patients underwent robotic nephrectomy with removal of IVC tumor thrombus and retroperitoneal lymph node dissection. Three patients underwent robotic explantation of an IVCF after multiple endovascular attempts at removal had failed. The patients with renal cell carcinoma were a mean age of was 65.4 years (range, 55-74 years). Six patients had right-sided malignancy. All patients had T3b lesions at time of diagnosis. Mean tumor length extension into the IVC was 5 cm (range, 1-8 cm). All patients underwent robotic radical nephrectomy, with caval tumor thrombus removal and retroperitoneal lymph node dissection. The average operative time for patients undergoing surgery for renal cell carcinoma was 273 minutes (range, 137-382 minutes). Average intraoperative blood loss was 428 mL (range, 150-1200 mL). The patients with IVCF removal were a mean age of 33 years (range, 24-41 years). Average time from IVCF placement until robotic removal was 35.5 months (range, 4.3-57.3 months). Before robotic IVCF removal, a minimum of two endovascular retrievals were attempted. Average operative time for patients undergoing IVCF removal was 163 minutes (range, 131-202 minutes). Intraoperative blood loss averaged 250 mL (range, 150-350 mL). All procedures were completed robotically. The mean length of stay for all patients was 3.5 days (range, 1-8 days). All patients resumed ambulation on postoperative day 1. Nine patients resumed a regular diet on postoperative day 2. One patient with a renal tumor sustained a colon injury during initial adhesiolysis, before robotic radical nephrectomy, which was recognized at the initial operation and repaired robotically. Robotic radical nephrectomy and caval tumor removal were then completed. No blood transfusions were required intraoperatively, but three patients required blood transfusions postoperatively. Although robotic IVC surgery is uncommon, our initial limited experience demonstrates it is safe and efficacious. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  7. Endotoxaemia-augmented murine venous thrombosis is dependent on TLR-4 and ICAM-1, and potentiated by neutropenia.

    PubMed

    Obi, Andrea T; Andraska, Elizabeth; Kanthi, Yogendra; Kessinger, Chase W; Elfline, Megan; Luke, Cathy; Siahaan, Teruna J; Jaffer, Farouc A; Wakefield, Thomas W; Henke, Peter K

    2017-01-26

    Venous thromboembolism is a major cause of death during and immediately post-sepsis. Venous thrombosis (VT) is mediated by cell adhesion molecules and leukocytes, including neutrophil extracellular traps (NETs). Sepsis, or experimentally, endotoxaemia, shares similar characteristics and is modulated via toll like receptor 4 (TLR4). This study was undertaken to determine if endotoxaemia potentiates early stasis thrombogenesis, and secondarily to determine the role of VT TLR4, ICAM-1 and neutrophils (PMNs). Wild-type (WT), ICAM-1 -/- and TLR4 -/- mice underwent treatment with saline or LPS (10 mg/kg i. p.) alone, or followed by inferior vena cava (IVC) ligation to generate stasis VT. In vivo microscopy of leukocyte trafficking was performed in non-thrombosed mice, and tissue and plasma were harvested during early VT formation. Pre-thrombosis, circulating ICAM-1 was elevated and increased leukocyte adhesion and rolling occurred on the IVC of LPS-treated mice. Post-thrombosis, endotoxaemic mice formed larger, platelet-poor thrombi. Endotoxaemic TLR4 -/- mice did not have an augmented thrombotic response and exhibited significantly decreased circulating ICAM-1 compared to endotoxaemic WT controls. Endotoxaemic ICAM-1 -/- mice had significantly smaller thrombi compared to controls. Hypothesising that PMNs localised to the inflamed endothelium were promoting thrombosis, PMN depletion using anti-Ly6G antibody was performed. Paradoxically, VT formed without PMNs was amplified, potentially related to endotoxaemia induced elevation of PAI-1 and circulating FXIII, and decreased uPA. Endotoxaemia enhanced early VT occurs in a TLR-4 and ICAM-1 dependent fashion, and is potentiated by neutropenia. ICAM-1 and/or TLR-4 inhibition may be a unique strategy to prevent sepsis-associated VT.

  8. Abnormal location of umbilical venous catheter due to Scimitar syndrome

    PubMed Central

    Mart, Christopher R; Van Dorn, Charlotte S

    2014-01-01

    Scimitar syndrome is a rare congenital anomaly where the right pulmonary veins return to the inferior vena cava (IVC) just below the diaphragm. On chest X-ray (CXR), an IVC catheter will be in a bizarre location outside the heart if it inadvertently passes into the scimitar vein rather than into the right atrium. PMID:25298705

  9. Selection of ribozymes that catalyse multiple-turnover Diels–Alder cycloadditions by using in vitro compartmentalization

    PubMed Central

    Agresti, Jeremy J.; Kelly, Bernard T.; Jäschke, Andres; Griffiths, Andrew D.

    2005-01-01

    In vitro compartmentalization (IVC) has previously been used to evolve protein enzymes. Here, we demonstrate how IVC can be applied to select RNA enzymes (ribozymes) for a property that has previously been unselectable: true intermolecular catalysis. Libraries containing 1011 ribozyme genes are compartmentalized in the aqueous droplets of a water-in-oil emulsion, such that most droplets contain no more than one gene, and transcribed in situ. By coencapsulating the gene, RNA, and the substrates/products of the catalyzed reaction, ribozymes can be selected for all enzymatic properties: substrate recognition, product formation, rate acceleration, and turnover. Here we exploit the complementarity of IVC with systematic evolution of ligands by exponential enrichment (SELEX), which allows selection of larger libraries (≥1015) and for very small rate accelerations (kcat/kuncat) but only selects for intramolecular single-turnover reactions. We selected ≈1014 random RNAs for Diels–Alderase activity with five rounds of SELEX, then six to nine rounds with IVC. All selected ribozymes catalyzed the Diels–Alder reaction in a truly bimolecular fashion and with multiple turnover. Nearly all ribozymes selected by using eleven rounds of SELEX alone contain a common catalytic motif. Selecting with SELEX then IVC gave ribozymes with significant sequence variations in this catalytic motif and ribozymes with completely novel motifs. Interestingly, the catalytic properties of all of the selected ribozymes were quite similar. The ribozymes are strongly product inhibited, consistent with the Diels–Alder transition state closely resembling the product. More efficient Diels–Alderases may need to catalyze a second reaction that transforms the product and prevents product inhibition. PMID:16260754

  10. Arts and Crafts of the Mississippi Hills. ESEA, Title IV-C, 1982-83.

    ERIC Educational Resources Information Center

    Eaton, Barbara; Weatherford, Martha

    An overview is presented of a 1982-83 Elementary and Secondary Education Act (ESEA), Title IV-C project, designed for 50 talented high school art students, to preserve the arts and crafts in the Mississippi hills area and to enrich existing arts and crafts curriculum. Steps are listed for implementing such a program, a simple program budget is…

  11. An Application of the PMI Model at the Project Level Evaluation of ESEA Title IV-C Projects.

    ERIC Educational Resources Information Center

    McBeath, Marcia

    All of the papers presented as part of a symposium concerned the application of the Planning, Monitoring, and Implementation Model (PMI) to the evaluation of the District of Columbia Public Schools' programs supported by the Elementary Secondary Education Act (ESEA) Title IV-C. PMI was developed to provide a model for systematic evaluation of…

  12. Application of Change Agent Study Findings to the Formulation of Title IVC: Local Role.

    ERIC Educational Resources Information Center

    Weinman, Janice

    This paper addresses three issues--current constraints on the local level that contribute to failures to bring about innovation, conditions that have been isolated as significant to the success of the change process, and ways in which Title IV-C of the Elementary and Secondary Education Act could encourage the presence of these favorable…

  13. Quantification of hepatic flow distribution using particle tracking for patient specific virtual Fontan surgery

    NASA Astrophysics Data System (ADS)

    Yang, Weiguang; Vignon-Clementel, Irene; Troianowski, Guillaume; Shadden, Shawn; Mohhan Reddy, V.; Feinstein, Jeffrey; Marsden, Alison

    2010-11-01

    The Fontan surgery is the third and final stage in a palliative series to treat children with single ventricle heart defects. In the extracardiac Fontan procedure, the inferior vena cava (IVC) is connected to the pulmonary arteries via a tube-shaped Gore-tex graft. Clinical observations have shown that the absence of a hepatic factor, carried in the IVC flow, can cause pulmonary arteriovenous malformations. Although it is clear that hepatic flow distribution is an important determinant of Fontan performance, few studies have quantified its relation to Fontan design. In this study, we virtually implanted three types of grafts (T-junction, offset and Y-graft) into 5 patient specific models of the Glenn (stage 2) anatomy. We then performed 3D time-dependent simulations and systematically compared the IVC flow distribution, energy loss, and pressure levels in different surgical designs. A robustness test is performed to evaluate the sensitivity of hepatic distribution to pulmonary flow split. Results show that the Y-graft design effectively improves the IVC flow distribution, compared to traditional designs and that surgical designs could be customized on a patient-by-patient basis.

  14. Estimation and tracking of AP-diameter of the inferior vena cava in ultrasound images using a novel active circle algorithm.

    PubMed

    Karami, Ebrahim; Shehata, Mohamed S; Smith, Andrew

    2018-05-04

    Medical research suggests that the anterior-posterior (AP)-diameter of the inferior vena cava (IVC) and its associated temporal variation as imaged by bedside ultrasound is useful in guiding fluid resuscitation of the critically-ill patient. Unfortunately, indistinct edges and gaps in vessel walls are frequently present which impede accurate estimation of the IVC AP-diameter for both human operators and segmentation algorithms. The majority of research involving use of the IVC to guide fluid resuscitation involves manual measurement of the maximum and minimum AP-diameter as it varies over time. This effort proposes using a time-varying circle fitted inside the typically ellipsoid IVC as an efficient, consistent and novel approach to tracking and approximating the AP-diameter even in the context of poor image quality. In this active-circle algorithm, a novel evolution functional is proposed and shown to be a useful tool for ultrasound image processing. The proposed algorithm is compared with an expert manual measurement, and state-of-the-art relevant algorithms. It is shown that the algorithm outperforms other techniques and performs very close to manual measurement. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. A case of huge colon carcinoma and right renal angiomyolipoma accompanied by proximal deep venous thrombosis, pulmonary embolism and tumor thrombus in the renal vein.

    PubMed

    Ban, Daisuke; Yamamoto, Seiichiro; Kuno, Hirofumi; Fujimoto, Hiroyuki; Fujita, Shin; Akasu, Takayuki; Moriya, Yoshihiro

    2008-10-01

    A preoperative inferior vena cava (IVC) filter is reported to be effective in surgical cases with proximal deep venous thrombosis (DVT) or in which pulmonary embolism (PE) has already developed, and considered to be at high risk of developing secondary fatal PE during or after surgery. However, guidelines for using an IVC filter have yet to be established. The patient in the present report had two huge tumors, ascending colon cancer and renal angiomyolipoma, which occupied the entire right half of the abdomen, coexisting PE, DVT and tumor thrombus in the right renal vein. Secondary PE is fatal in the perioperative period, therefore, the vena cava filters were preoperatively inserted into the supra- and the infrarenal IVC. We successfully removed the tumors without complications. The patient is alive without tumor recurrence and PE or recurrent DVT 1 year and 6 months after surgery. The coexistence of two huge abdominal tumors as potential causes of PE and DVT is extremely rare, and we could have safely undergone the operation, using two vena cava filters in the supra- and infrarenal IVC.

  16. Acetylcysteine Rinse in Reducing Saliva Thickness and Mucositis in Patients With Head and Neck Cancer Undergoing Radiation Therapy

    ClinicalTrials.gov

    2018-04-17

    Mucositis; Oral Complications; Recurrent Adenoid Cystic Carcinoma of the Oral Cavity; Recurrent Basal Cell Carcinoma of the Lip; Recurrent Lymphoepithelioma of the Nasopharynx; Recurrent Lymphoepithelioma of the Oropharynx; Recurrent Mucoepidermoid Carcinoma of the Oral Cavity; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Stage I Adenoid Cystic Carcinoma of the Oral Cavity; Stage I Basal Cell Carcinoma of the Lip; Stage I Lymphoepithelioma of the Nasopharynx; Stage I Lymphoepithelioma of the Oropharynx; Stage I Mucoepidermoid Carcinoma of the Oral Cavity; Stage I Salivary Gland Cancer; Stage I Squamous Cell Carcinoma of the Larynx; Stage I Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage I Squamous Cell Carcinoma of the Nasopharynx; Stage I Squamous Cell Carcinoma of the Oropharynx; Stage I Verrucous Carcinoma of the Larynx; Stage I Verrucous Carcinoma of the Oral Cavity; Stage II Adenoid Cystic Carcinoma of the Oral Cavity; Stage II Basal Cell Carcinoma of the Lip; Stage II Lymphoepithelioma of the Nasopharynx; Stage II Lymphoepithelioma of the Oropharynx; Stage II Mucoepidermoid Carcinoma of the Oral Cavity; Stage II Salivary Gland Cancer; Stage II Squamous Cell Carcinoma of the Larynx; Stage II Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage II Squamous Cell Carcinoma of the Nasopharynx; Stage II Squamous Cell Carcinoma of the Oropharynx; Stage II Verrucous Carcinoma of the Larynx; Stage II Verrucous Carcinoma of the Oral Cavity; Stage III Adenoid Cystic Carcinoma of the Oral Cavity; Stage III Basal Cell Carcinoma of the Lip; Stage III Lymphoepithelioma of the Nasopharynx; Stage III Lymphoepithelioma of the Oropharynx; Stage III Mucoepidermoid Carcinoma of the Oral Cavity; Stage III Salivary Gland Cancer; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Lymphoepithelioma of the Nasopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVA Basal Cell Carcinoma of the Lip; Stage IVA Lymphoepithelioma of the Oropharynx; Stage IVA Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVB Basal Cell Carcinoma of the Lip; Stage IVB Lymphoepithelioma of the Oropharynx; Stage IVB Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVC Basal Cell Carcinoma of the Lip; Stage IVC Lymphoepithelioma of the Oropharynx; Stage IVC Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer

  17. Paclitaxel and Carboplatin Before Radiation Therapy With Paclitaxel in Treating HPV-Positive Patients With Stage III-IV Oropharynx, Hypopharynx, or Larynx Cancer

    ClinicalTrials.gov

    2017-04-19

    Human Papilloma Virus Infection; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Verrucous Carcinoma of the Larynx; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Verrucous Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Verrucous Carcinoma of the Larynx

  18. Mice prefer draught-free housing.

    PubMed

    Krohn, T C; Hansen, A K

    2010-10-01

    An increasing number of rodents are housed in individually ventilated cage (IVC) systems, as these seem to be very effective for the protection of animals against infections, as well as protecting the staff against allergens. For the IVC systems to be properly ventilated, a huge amount of air has to be blown into the cage, which may cause a draught at animal level inside the cage. The aim of the present study was to evaluate the preferences of mice for differing levels of air speeds and air changes inside the cage. It has been concluded that mice do react to draughts, whereas they do not seem to be affected by a high number of air changes delivered without draught, which underlines the importance of applying draught-free IVC systems for mice.

  19. Physiologic Effect of Stent Therapy for Inferior Vena Cava Obstruction Due to Malignant Liver Tumor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kishi, Kazushi; Sonomura, Tetsuo; Fujimoto, Hisashi

    Purpose. To understand systemic the influence of stent therapy for inferior vena cava (IVC) obstruction due to advanced liver tumor. Methods. Seven patients with symptomatic IVC obstruction due to advanced primary (n 4) or secondary (n = 3) liver tumor were subjected to stent therapy. Enrollment criteria included high IVC pressure over 15 mmHg and the presence of edema and ascites. Z-stents were deployed using coaxial sheath technique via femoral venous puncture. Physiologic and hematobiochemical parameters were analyzed. Results. All procedures were successful, and the stents remained patent until patient death. Promptly after stent placement, the IVC flow recovered, andmore » the venous blood pressure in the IVC below the obstruction level showed a significant decrease from 20.8 {+-} 1.2 mmHg (mean {+-} SE) to 10.7 {+-} 0.7 mmHg (p < 0.01). Transient mild increase of right atrial pressure was observed in 1 patient. During the following week prominent diuresis was observed in all patients. Mean urine output volume in the 3 days before the stent therapy was 0.81 {+-} 0.09 l/day compared with 2.1 {+-} 0.2 l/day (p < 0.01) in the 3 days after. The edema and ascites decreased in all patients. The caval pressure change correlated well (r > 0.6) with the urine volume increase, and with the decreased volume of edema and ascites. The urine volume increase correlated well with the decrement of edema, but not with that of ascites. Improvements for various durations in the levels of blood urea nitrogen, serum creatinine, lactate dehydrogenase, fibrinogen, and platelet count were found (p < 0.05). These hematobiochemical changes were well correlated with each other and with the decrement of ascites. Two patients showed a low blood sodium level of 128.5 mEq/l after intensive natriuresis, and one of them died on day 21 with hepatic failure, which was interpreted as maladaptation aggravation. The mean survival time was 94.1 {+-} 34.1 days (mean {+-} SD), ranging from 21 to 140 days after stent treatment. Conclusion. The stent therapy for IVC obstruction due to malignant liver tumors was followed by a series of physiologic and hematobiochemical consequences, most of them favorable but some possibly unfavorable. Rational interpretations and predictions of sequelae based on physiologic science including cardiology, hepatology, and nephrology would facilitate the best management of stent therapy for malignant IVC obstruction.« less

  20. Clinical Sequelae of Thrombus in an Inferior Vena Cava Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmad, Iftikhar; Yeddula, Kalpana; Wicky, Stephan

    The purpose of this study was to assess the long-term clinical sequelae of inferior vena cava (IVC) filter thrombus and the effect of anticoagulation on filter thrombus. Of 1,718 patients who had IVC filters placed during 2001-2008, 598 (34.8%) had follow-up abdominal CT. Filter thrombus was seen in 111 of the 598 (18.6%). There were 44 men (39.6%). The mean age at filter placement was 64 years. The medical diseases included cancer in 64, trauma in 15, stroke in 12, and others in 20. The frequency of filter thrombus on CT and asymptomatic filter thrombus on CT was calculated. Themore » frequency of pulmonary embolism (PE) in patients with filter thrombus was calculated. The frequency of thrombus progression or regression (on CT, available in 56) was calculated. The effect of anticoagulation on filter thrombus regression/progression was evaluated using the Fisher exact test by comparing the group of patients who received anticoagulants versus those who did not. A P-value of <0.05 was considered significant. The overall frequency of filter thrombus was 18.6%. Total occlusion of the IVC filter was seen in 12 of 598 (2%). The filter thrombus was asymptomatic in 110 (18.3%). Filter thrombus was detected after a median of 35 days (range, 0-2082) following filter placement. Thrombus extended above the filter in 4 (3.6%); IVC thrombus below the filter was seen in 35(31.5%). Thrombus in the filter occluded <25% of the filter volume in 58 (52.3%), 25-50% in 21 (18.9%), and 50-75% in 20 (18%). Total IVC occlusion was seen in 12 (10.8%). Eighty-three patients received anticoagulation. Sixteen patients developed symptoms of PE. PE was confirmed on CT in 3 of 15 (2.7%). On follow-up, filter thrombus regressed completely in 19 (33.9%) after a median of 6 months. Filter thrombus decreased in size in 13 (23.2%) and it progressed without IVC occlusion in 7 (12.6%). In one (1.7%), filter thrombus progressed to IVC occlusion. Filter thrombus remained stable in 16 (28.6%). There was no significant difference in thrombus regression or progression rates whether or not the patients received anticoagulation for filter thrombus. In conclusion, asymptomatic thrombus in the filter is common and it rarely progresses to complete caval occlusion. Anticoagulation has little effect on the resolution of filter thrombosis and future occurrence of PE.« less

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalva, Sanjeeva P., E-mail: skalva@partners.org; Athanasoulis, Christos A.; Fan, C.-M.

    The purpose of the study was to assess the clinical safety and efficacy of the 'Recovery{sup TM}' (Bard) inferior vena cava (IVC) filter. We retrospectively evaluated the clinical and imaging data of patients who had a 'Recovery{sup TM}' IVC filter placed between January 2003 and December 2004 in our institution. The clinical presentation, indications, and procedure-related complications during placement and retrieval were evaluated. Follow-up computed tomography (CT) examinations of the abdomen and chest were evaluated for filter-related complications and pulmonary embolism (PE), respectively. 'Recovery' filters were placed in 96 patients (72 males and 24 females; age range: 16-87 years; mean:more » 46 years). Twenty-four patients presented with PE, 13 with deep vein thrombosis (DVT) and 2 with both PE and DVT. The remaining 57 patients had no symptoms of thromboembolism. Indications for filter placement included contraindication to anticoagulation (n = 27), complication of anticoagulation (n = 3), failure of anticoagulation (n = 5), and prophylaxis (n = 61). The device was successfully deployed in the infrarenal (n = 95) or suprarenal (n = 1) IVC through a femoral vein approach. Retrieval was attempted in 11 patients after a mean period of 117 days (range: 24-426). The filter was successfully removed in nine patients (82%). Failure of retrieval was due to technical difficulty (n = 1) and the presence of thrombus in the filter (n = 1). One of the nine patients who had the filter removed developed IVC thrombus after retrieval and another had an intimal tear of the IVC. Follow-up abdominal CT (n = 40) at a mean of 80 days (range: 1-513) showed penetration of the IVC by the filter arms in 11, of which 3 had fracture of filter components. In one patient, a broken arm migrated into the pancreas. Asymmetric deployment of the filter legs was seen in 12 patients and thrombus within the filter in 2 patients. No filter migration or caval occlusion was encountered. Follow-up chest CT (n = 27) at a mean of 63 days (range: 1-386) showed PE in one patient (3%). During clinical follow-up, 12 of 96 patients developed symptoms of PE and only 1 of the 12 had PE on CT. There was no fatal pulmonary embolism in our group of patients following 'Recovery' filter placement. However, the current version of the filter is associated with structure weakness, a high incidence of IVC wall penetration, and asymmetric deployment of the filter legs.« less

  2. Effect of high-dose intravenous vitamin C on inflammation in cancer patients.

    PubMed

    Mikirova, Nina; Casciari, Joseph; Rogers, Andrea; Taylor, Paul

    2012-09-11

    An inflammatory component is present in the microenvironment of most neoplastic tissues. Inflammation and elevated C-reactive protein (CRP) are associated with poor prognosis and decreased survival in many types of cancer.Vitamin C has been suggested as having both a preventative and therapeutic role in a number of pathologies when administered at much higher-than-recommended dietary allowance levels.Since in vitro studies demonstrated inhibition of pro-inflammatory pathways by millimolar concentrations of vitamin C, we decided to analyze the effects of high dose IVC therapy in suppression of inflammation in cancer patients. 45 patients with prostate cancer, breast cancer, bladder cancer, pancreatic cancer, lung cancer, thyroid cancer, skin cancer and B-cell lymphoma were treated at the Riordan Clinic by high doses of vitamin C (7.5 g -50 g) after standard treatments by conventional methods.CRP and tumor markers were measured in serum or heparin-plasma as a routine analysis. In addition, serum samples were collected before and after the IVCs for the cytokine kit tests. According to our data positive response to treatment, which was demonstrated by measurements of C- reactive protein, was found in 75% of patients and progression of the inflammation in 25% of patients. IVC treatments on all aggressive stage cancer patients showed the poor response of treatment.There was correlation between tumor markers (PSA, CEA, CA27.29 and CA15-3) and changes in the levels of C-reactive protein.Our test of the effect of IVC on pro-inflammatory cytokines demonstrated that inflammation cytokines IL-1α, IL-2, IL-8, TNF-α, chemokine eotaxin and CRP were reduced significantly after treatments. The high dose intravenous ascorbic acid therapy affects C-reactive protein levels and pro-inflammation cytokines in cancer patients. In our study, we found that modulation of inflammation by IVC correlated with decreases in tumor marker levels.In summary, our data support the hypothesis that high dose intravenous ascorbate treatments may reduce inflammation in cancer patients. Our results suggest that further investigations into the use of IVC to reduce inflammation in diseases where inflammation is relevant are warranted.

  3. The perioperative management of an inferior vena caval tumor thrombus in patients with renal cell carcinoma.

    PubMed

    Woodruff, Daniel Y; Van Veldhuizen, Peter; Muehlebach, Gregory; Johnson, Phillip; Williamson, Timothy; Holzbeierlein, Jeffrey M

    2013-07-01

    Inferior vena caval tumor thrombus (IVC-TT) occurs in 10% of patients diagnosed with renal cell carcinoma (RCC). The perioperative management of these patients remains challenging. Despite multiple publications outlining surgical approaches and outcomes there have been few studies detailing the best peri-operative management of patients with IVC-TT. Our goal was to define the optimal management of patients with RCC and IVC-TT. A review of all published literature regarding the management of RCC with IVC-TT was performed utilizing Pub Med and the Cochrane Database. Reviews were also made of all relevant literature regarding the need for cardiopulmonary bypass and recommendations regarding thrombus in any location in patients with malignancy. Specific items critically examined included: need for preoperative heart catheterization, need for anticoagulation and type of anticoagulation, need for additional studies such as lower extremity duplex or venogram, and indications for vena caval filter placement. The results were then presented to a multidisciplinary group made up of experts in the fields of Urology, Hematology, Oncology, Cardiothoracic Surgery, Interventional Radiology, and Pulmonary/Critical Care. Based on the available literature a best practice guidelines regarding the management of RCC with IVC-TT was established at our institution. Our institutional recommendations include (1) preoperative cardiac catheterization in all patients believed to require cardiopulmonary bypass for removal of the thrombus but only cardiac clearance for those who bypass is unlikely, (2) preoperative anticoagulation using a low molecular weight heparin such as enoxaparin unless contraindicated due to bleeding from the tumor or other contraindication, (3) avoidance of vena caval filters whenever possible is recommended due the potential for caval thrombosis and the difficulties they present during surgical resection. This study identified the available literature on the management of IVC-TT in association with RCC and was carefully reviewed by a multidisciplinary team. As a result, we have established a set of practice guidelines at our institution to help optimally manage patients with renal cell carcinoma and an inferior venal caval thrombus. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Effect of high-dose intravenous vitamin C on inflammation in cancer patients

    PubMed Central

    2012-01-01

    Background An inflammatory component is present in the microenvironment of most neoplastic tissues. Inflammation and elevated C-reactive protein (CRP) are associated with poor prognosis and decreased survival in many types of cancer. Vitamin C has been suggested as having both a preventative and therapeutic role in a number of pathologies when administered at much higher-than-recommended dietary allowance levels. Since in vitro studies demonstrated inhibition of pro-inflammatory pathways by millimolar concentrations of vitamin C, we decided to analyze the effects of high dose IVC therapy in suppression of inflammation in cancer patients. Methods 45 patients with prostate cancer, breast cancer, bladder cancer, pancreatic cancer, lung cancer, thyroid cancer, skin cancer and B-cell lymphoma were treated at the Riordan Clinic by high doses of vitamin C (7.5 g -50 g) after standard treatments by conventional methods. CRP and tumor markers were measured in serum or heparin-plasma as a routine analysis. In addition, serum samples were collected before and after the IVCs for the cytokine kit tests. Results According to our data positive response to treatment, which was demonstrated by measurements of C- reactive protein, was found in 75% of patients and progression of the inflammation in 25% of patients. IVC treatments on all aggressive stage cancer patients showed the poor response of treatment. There was correlation between tumor markers (PSA, CEA, CA27.29 and CA15-3) and changes in the levels of C-reactive protein. Our test of the effect of IVC on pro-inflammatory cytokines demonstrated that inflammation cytokines IL-1α, IL-2, IL-8, TNF-α, chemokine eotaxin and CRP were reduced significantly after treatments. Conclusions The high dose intravenous ascorbic acid therapy affects C-reactive protein levels and pro-inflammation cytokines in cancer patients. In our study, we found that modulation of inflammation by IVC correlated with decreases in tumor marker levels. In summary, our data support the hypothesis that high dose intravenous ascorbate treatments may reduce inflammation in cancer patients. Our results suggest that further investigations into the use of IVC to reduce inflammation in diseases where inflammation is relevant are warranted. PMID:22963460

  5. New data on selected Ivory Coast tektites

    USGS Publications Warehouse

    Cuttitta, F.; Carron, M.K.; Annell, C.S.

    1972-01-01

    Fourteen Ivory Coast tektites exhibit a range of bulk indices of refraction of 1.5156 to 1.5217 ?? 0.0004 and of bulk specific gravities of 2.428 to 2.502 ??0.005. Seven of these Ivory Coast (IVC) tektites were analyzed for major and minor element content. Compared to tektites from other strewn fields, their SiO2 content is low (67.2-69.1 %), A12O3 relatively high (15.8-16.8 %), and total iron relatively high but with a more restricted range (6.3-6.8 % as FeO). Their lime content is low (0.71-1.35%) compared to Australasian tektites but their MgO CaO ratio (about 3.1) is unusually high. All other tektite groups have Na2O K2O ratios less than unity, but the Na2O K2O ratio of the IVC tektites is slightly greater than unity. Their K Rb ratios range from 200 to 256 and average 227, which is higher than those determined for Australasian tektites, but similar to some obtained for moldavites. The Li content (41-48 ppm) is about the same as that of the Australasian tektites, but the Cs and Rb are lower, being 1.9 to 2.9 and 57 to 86 ppm, respectively. The IVC tektites are high in Cr (260-375 ppm), Co (19-25 ppm) and Ni (101-167 ppm), and particularly in Pb (<10-18 ppm), Cu (13-21 ppm) and Ga (14-23 ppm). The high Cr Ni ratios of the IVC tektites (range 2-3.6) are similar to those found for australites, philippinites and thailandites, but not the javanites and indochinites. Evaluation of these and other reported data show that compositional similarities between the IVC tektites and green or black Bosumtwi Crater glasses strongly support the hypothesis of a common impact origin-i.e. the Bosumtwi Crater site. Comparison of the IVC tektite composition with those of returned lunar materials (gabbros, basalts, breccia and soils) do not support a lunar origin for the Ivory Coast tektites. ?? 1972.

  6. Differences in radial expansion force among inferior vena cava filter models support documented perforation rates.

    PubMed

    Robins, J Eli; Ragai, Ihab; Yamaguchi, Dean J

    2018-05-01

    Inferior vena cava (IVC) filters are used in patients at risk for pulmonary embolism who cannot be anticoagulated. Unfortunately, these filters are not without risk, and complications include perforation, migration, and filter fracture. The most prevalent complication is filter perforation of the IVC, with incidence varying among filter models. To our knowledge, the mechanical properties of IVC filters have not been evaluated and are not readily available through the manufacturer. This study sought to determine whether differences in mechanical properties are similar to differences in documented perforation rates. The radial expansion forces of Greenfield (Boston Scientific, Marlborough, Mass), Cook Celect (Cook Medical, Bloomington, Ind), and Cook Platinum filters were analyzed with three replicates per group. The intrinsic force exerted by the filter on the measuring device was collected in real time during controlled expansion. Replicates were averaged and significance was determined by calculating analysis of covariance using SAS software (SAS Institute, Cary, NC). Each filter model generated a significantly different radial expansion force (P < .001), and force was distributed at significantly different rates (P < .001) during expansion. The largest radial expansion force at minimal caval diameter was seen in the Cook Platinum filter, followed by the Cook Celect and Greenfield filters. Radial force dispersion during expansion was greatest in the Cook Celect, followed by the Cook Platinum and Greenfield filters. Differences in radial expansion forces among IVC filter models are consistent with documented perforation rates. Cook Celect IVC filters have a higher incidence of perforation compared with Greenfield filters when they are left in place for >90 days. Evaluation of Cook Celect filters yielded a significantly higher radial expansion force at minimum caval diameter, with greater force dispersion during expansion. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  7. Inferior vena cava filter insertion through the popliteal vein: enabling the percutaneous endovenous intervention of deep vein thrombosis with a single venous access approach in a single session

    PubMed Central

    Kim, Hyoung Ook; Kim, Jae Kyu; Park, Jin Gyoon; Yim, Nam Yeol; Kang, Yang Jun; Jung, Hye Doo

    2016-01-01

    PURPOSE We aimed to evaluate the efficiency of placing an inferior vena cava (IVC) filter through the same popliteal vein access site used for percutaneous endovenous intervention in patients with extensive lower extremity deep vein thrombosis. METHODS This retrospective study included 21 patients who underwent IVC filter insertion through the popliteal vein over a three-year period. Patient medical records were reviewed for the location of the deep vein thrombosis, result of filter removal, and total number of endovascular procedures needed for filter insertion and recanalization of the lower extremity venous system. Follow-up lower extremity computed tomography (CT) venography was also reviewed in each patient to assess the degree of filter tilt in the IVC. RESULTS All patients had extensive lower extremity deep vein thrombosis involving the iliac vein and/or femoral vein. Seventeen patients showed deep vein thrombosis of the calf veins. In all patients, IVC filter insertion and the recanalization procedure were performed during a single procedure through the single popliteal vein access site. In the 17 patients undergoing follow-up CT, the mean tilt angle of the filter was 7.14°±4.48° in the coronal plane and 8.77°±5.49° in the sagittal plane. Filter retrieval was successful in 16 of 17 patients (94.1%) in whom filter retrieval was attempted. CONCLUSION Transpopliteal IVC filter insertion is an efficient technique that results in low rates of significant filter tilt and enables a single session procedure using a single venous access site for filter insertion and percutaneous endovenous intervention. PMID:27559713

  8. Sonographic aorta/IVC cross-sectional area index for evaluation of dehydration in children.

    PubMed

    Kwon, Hyuksool; Jung, Jae Yun; Lee, Jin Hee; Kwak, Young Ho; Kim, Do Kyun; Jung, Jin Hee; Chang, Ik Wan; Kim, Kyuseok

    2016-09-01

    Current studies have not found sufficient evidence to encourage the use of ultrasound for assessing dehydration in children. We introduce a new sonographic parameter, the "aorta/inferior vena cava (IVC) cross-sectional area index" (Ao/IVCA) measured just inferior to the xiphoid process, for the effective evaluation of dehydration in children. This is a prospective, observational study. We enrolled children who presented to the pediatric emergency department (PED) between May 2014 and January 2015. We measured the maximum diameter of the aorta from inner wall to inner wall, and the long and short axis diameters of IVC using a convex array transducer. Ao/IVCA was calculated and compared with aorta/IVC maximal diameter index (Ao/IVCD) and the clinical dehydration scale (CDS). A total of 34 children were enrolled. We found a statistically significant correlation between Ao/IVCA and CDS (R(2) = 0.30; P <.001). Ao/IVCD did not correlate significantly with CDS (R(2) = 0.08; P =.11). The ability of Ao/IVCA and Ao/IVCD to predict CDS ≥1 was assessed using the receiver operating characteristic analysis. The area under the receiver operating characteristic curve for Ao/IVCA was larger than that for Ao/IVCD (0.87 vs 0.75, P= .04). The cut-off value of Ao/IVCA that yielded the maximum value of Youden index was 1.81 (sensitivity: 72%, specificity: 89%). Ao/IVCA might be a promising index for the assessment of dehydration. The diagnostic performance of Ao/IVCA for dehydration might be higher than that of the method that uses the maximum diameter of IVC and the aorta. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Inferior vena cava segmentation with parameter propagation and graph cut.

    PubMed

    Yan, Zixu; Chen, Feng; Wu, Fa; Kong, Dexing

    2017-09-01

    The inferior vena cava (IVC) is one of the vital veins inside the human body. Accurate segmentation of the IVC from contrast-enhanced CT images is of great importance. This extraction not only helps the physician understand its quantitative features such as blood flow and volume, but also it is helpful during the hepatic preoperative planning. However, manual delineation of the IVC is time-consuming and poorly reproducible. In this paper, we propose a novel method to segment the IVC with minimal user interaction. The proposed method performs the segmentation block by block between user-specified beginning and end masks. At each stage, the proposed method builds the segmentation model based on information from image regional appearances, image boundaries, and a prior shape. The intensity range and the prior shape for this segmentation model are estimated based on the segmentation result from the last block, or from user- specified beginning mask if at first stage. Then, the proposed method minimizes the energy function and generates the segmentation result for current block using graph cut. Finally, a backward tracking step from the end of the IVC is performed if necessary. We have tested our method on 20 clinical datasets and compared our method to three other vessel extraction approaches. The evaluation was performed using three quantitative metrics: the Dice coefficient (Dice), the mean symmetric distance (MSD), and the Hausdorff distance (MaxD). The proposed method has achieved a Dice of [Formula: see text], an MSD of [Formula: see text] mm, and a MaxD of [Formula: see text] mm, respectively, in our experiments. The proposed approach can achieve a sound performance with a relatively low computational cost and a minimal user interaction. The proposed algorithm has high potential to be applied for the clinical applications in the future.

  10. Effect of Pseudomonas aeruginosa on sperm capacitation and protein phosphorylation of boar spermatozoa.

    PubMed

    Sepúlveda, Lilian; Bussalleu, Eva; Yeste, Marc; Bonet, Sergi

    2016-05-01

    Several studies have reported the detrimental effects that bacteriospermia causes on boar sperm quality, but little is known about its effects on IVC. Considering that, the present study sought to evaluate the effects of different concentrations of Pseudomonas aeruginosa on different indicators of capacitation status (sperm viability, membrane lipid disorder, sperm motility kinematics, and protein phosphorylation of boar spermatozoa) after IVC. Flow cytometry and computer assisted sperm analysis (CASA) revealed that the presence of P aeruginosa in boar sperm samples, mostly at concentrations greater than 10(6) CFU/mL, is associated with a significant (P < 0.05) decrease in the percentages of both sperm membrane integrity and sperm with low membrane lipid disorder, and also with a reduction in sperm motility kinetic parameters when compared with results obtained from the control sample, which presented the typical motility pattern of capacitated-like boar spermatozoa. Moreover, Western blot results also showed significant (P < 0.05) changes in the levels of tyrosine, serine, and threonine protein phosphorylation because of bacterial contamination, the decrease in phosphotyrosine levels of p32, a well-known marker of IVC achievement in boar sperm, being the most relevant. Indeed, after 3 hours of IVC, phosphotyrosine levels of p32 in the control sample were 3.13 ± 0.81, whereas in the tubes with 10(6) and 10(8) CFU/mL were 1.05 ± 0.20 and 0.36 ± 0.07, respectively. Therefore, the present study provides novel data regarding the effects of bacterial contamination on boar sperm, suggesting that the presence of P aeruginosa affects the fertilizing ability of boar sperm by altering its ability to accomplish IVC. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Low vacuum and discard tubes reduce hemolysis in samples drawn from intravenous catheters.

    PubMed

    Heiligers-Duckers, Connie; Peters, Nathalie A L R; van Dijck, Jose J P; Hoeijmakers, Jan M J; Janssen, Marcel J W

    2013-08-01

    In-vitro hemolysis is a great challenge to emergency departments where blood is drawn from intravenous catheters (IVCs). Although high quality samples can be obtained by straight needle venipuncture, IVCs are preferred for various reasons. The aim of this study was to identify blood collection practices that reduce hemolysis while using IVC. The study was conducted at an emergency department where blood is drawn in ≥ 90% of patients from IVC. Hemolysis, measured spectrophotometrically, was compared between syringe and vacuum tubes. The following practices were tested in combination with vacuum collection; a Luer-slip adapter, a Luer-lock adapter, discard tubes and low vacuum tubes. Each intervention lasted 1 week and retrieved 154 to 297 samples. As reference, hemolysis was also measured in vacuum tubes retrieved from departments where only straight needle venipuncture is performed. Vacuum collection led to more hemolytic samples compared with syringe tubes (24% versus 16% respectively, p=0.008). No difference in hemolysis was observed between the Luer-slip and the Luer-lock adapter. The use of discard (17% hemolytic, p=0.045) and low vacuum tubes (12% hemolytic, p<0.001) substantially decreased hemolysis. None of the interventions reduced the hemolysis rate to the level observed when drawing blood by straight needle venipuncture (3%, p<0.02). In summary, both discard and low vacuum tubes reduce hemolysis while drawing blood from IVC. Of these practices the use of a low vacuum tube is preferred considering the less volume of blood and the amount of tubes drawn. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. The Clinical Presentation, Survival Outcomes, and Management of Patients With Renal Cell Carcinoma and Cardiac Metastasis Without Inferior Vena Cava Involvement: Results From a Pooled Clinical Trial Database and Systematic Review of Reported Cases.

    PubMed

    Viteri Malone, Mariuxi A; Ares, Gustavo Ruiz; De Velasco, Guillermo; Brandão, Raphael; Lin, Xun; Norton, Craig; Simantov, Ronit; Moslehi, Javid; Krajewski, Katherine M; Choueiri, Toni K; McKay, Rana R

    2018-04-01

    Cardiac metastases from renal cell carcinoma (RCC) are uncommon and there are limited data regarding the presentation and outcomes of this population. The objective of this study was to evaluate the characteristics and outcomes of patients with RCC with cardiac metastasis without inferior vena cava (IVC) involvement. We conducted a pooled retrospective analysis of metastatic RCC patients treated in 4 clinical trials. Additionally, we conducted a systematic review of cases reported in the literature from 1973 to 2015. Patients with cardiac metastases from RCC without IVC involvement were included. Patient and disease characteristics were described. Additionally, treatments, response to therapy, and survival outcomes were summarized. Of 1765 metastatic RCC patients in the clinical trials database, 10 had cardiac metastases without IVC involvement. All patients received treatment with targeted therapy. There was 1 observed partial response (10%) and 6 patients showed stable disease (60%). The median progression-free survival was 6.9 months. The systematic review of reported clinical cases included 39 patients. In these patients, the most common cardiac site of involvement was the right ventricle (51%; n = 20). Patients were treated with medical (28%; n = 11) and/or surgical treatment (49%; n = 19) depending on whether disease was isolated (n = 13) or multifocal (n = 26). To our knowledge, this is the first series to report on the presentation and outcomes of patients with cardiac metastasis without IVC involvement in RCC. We highlight that although the frequency of patients with cardiac metastases without IVC involvement is low, these patients have a unique clinical presentation and warrant special multidisciplinary management. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Management and outcome of patients with acute myocardial infarction presenting with pacemaker rhythm.

    PubMed

    Bertel, Noemi; Witassek, Fabienne; Puhan, Milo; Erne, Paul; Rickli, Hans; Naegeli, Barbara; Pedrazzini, Giovanni; Stauffer, Jean-Christophe; Radovanovic, Dragana

    2017-03-01

    Diagnosis of acute myocardial infarction (MI) is challenging in pacemaker patients. Little is known about this patient group. Patients with MI enrolled in the Swiss national AMIS Plus registry between January 2005 and December 2015 were analyzed. All patients with either paced ventricular rhythm or sinus rhythm with intrinsic ventricular conduction (IVC) were included in this study. Outcomes using crude data and propensity score matching were compared between patients with pacemaker rhythm and patients with IVC. The primary endpoint was in-hospital death. Data from 300 patients with paced rhythm and 27,595 with IVC were analyzed. Patients with pacemaker rhythm were older (78.2y vs 65.4y; p<0.001), had more comorbidities (Charlson Index (CCI)>1: 54.0% vs 21.1%; p<0.001) and a higher rate of heart failure upon presentation (Killip class>2, 11.0% vs 5.9%; p<0.001) compared to patients with IVC. Door to balloon time in patients undergoing acute PCI is markedly delayed in contrast to patients with IVC (280min vs 85min; p<0.001). Consequently, crude mortality in patients with pacemakers was high (11.3% vs 4.6%; p<0.001). However, when analyzed with propensity matching for gender, age, CCI>1 and Killip>2, mortality was similar (11.2% vs 10.5%; p=0.70). Pacemaker patients with acute MI represent a high-risk group with doubled crude mortality compared to patients without pacemakers, due to higher age and higher Killip class. Diagnosis is difficult and results in delayed treatment. Treatment algorithms for MI with paced rhythm should possibly be adapted to those used for STEMI or new left bundle branch block. NCT01305785. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Role of IVC Filters in Endovenous Therapy for Deep Venous Thrombosis: The FILTER-PEVI (Filter Implantation to Lower Thromboembolic Risk in Percutaneous Endovenous Intervention) Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharifi, Mohsen, E-mail: seyedmohsensharifi@yahoo.com; Bay, Curt; Skrocki, Laura

    Objectives: The purpose of this study was to evaluate the necessity of and recommend indications for inferior vena cava (IVC) filter implantation during percutaneous endovenous intervention (PEVI) for deep venous thrombosis (DVT).BackgroundPEVI has emerged as a powerful tool in the management of acute proximal DVT. Instrumentation of extensive fresh thrombus is potentially associated with iatrogenic pulmonary embolism (PE). The true frequency of this complication has not been studied in a randomized fashion. We evaluated IVC filter implantation during PEVI for DVT. Methods: A total of 141 patients with symptomatic proximal DVT undergoing PEVI for symptomatic DVT were randomized to receivemore » an IVC filter (70 patients) or no filter (71 patients; control group). The anticoagulation and PEVI regimen were similar between the two groups. Patients with development of symptoms suggestive of PE underwent objective testing for PE. Results: PE developed in 1 of the 14 symptomatic patients in the filter group and 8 of the 22 patients in the control group (P = 0.048). There was no mortality in any group. Three patients (4.2%) in the control group had transient hemodynamic instability necessitating resuscitory efforts. Predictors of iatrogenic PE were found to be PE at admission; involvement of two or more adjacent venous segments with acute thrombus; inflammatory form of DVT (severe erythema, edema, pain, and induration); and vein diameter of {>=}7 mm with preserved architecture. Conclusions: IVC filter implantation during PEVI reduces the risk of iatrogenic PE by eightfold without a mortality benefit. A selective approach may be exercised in filter implantation during PEVI.« less

  15. Comparison of the effect of bone marrow cells infusion through the portal vein and inferior vena cava combined with short-term rapamycin on allogeneic islet grafts in diabetic rats.

    PubMed

    Gao, Qingzhen; Wang, Xiaoping; Zhang, Ruibin; Wang, Pu; Jing, Yongsheng; Ren, Wanjun; Zhu, Bin

    2016-07-01

    The study aimed to compare the impact of allogeneic bone marrow cells (BMCs) infusion through the inferior vena cava (IVC) and portal vein (PV) combined with rapamycin on allogeneic islet grafts in diabetic rats. Recipient diabetic Wistar rats were infused with islets from Sprague-Dawley rats through the PV. PKH26-labeled BMCs of Sprague-Dawley rats were infused to recipients through the PV or IVC, followed by administration of rapamycin for 4 days. Blood glucose level was measured to evaluate the survival time of the islets. Lymphocytes separated from blood, BMCs, thymus, liver, spleen and lymph node were analyzed by flow cytometry. The peripheral blood smear, BMCs smear and frozen sections of tissues were observed by a fluorescence microscope. The survival time of the islets was significantly prolonged by the BMCs infusion combined with rapamycin. The rats receiving BMCs infusion through the PV induced a significantly longer survival time of the islets, and increased mixed chimeras of allogeneic BMCs in the thymus, liver, spleen and lymph node compared with the rats receiving BMCs infusion through the IVC. The amount of the mixed chimeras on day 14 was lower than that on day 7 after islet transplantation. Furthermore, PV transplantation had significantly more mixed chimera than IVC transplantation in all analyzed organs or tissues. BMCs infusion combined with rapamycin prolongs the islets survival and induces mixed chimeras of BMCs. PV infusion of BMCs might be a more effective strategy than IVC infusion of BMCs. © 2015 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.

  16. Percutaneous Selective Embolectomy using a Fogarty Thru-Lumen Catheter for Pancreas Graft Thrombosis: A Case Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Izaki, Kenta, E-mail: izaki@med.kobe-u.ac.jp; Yamaguchi, Masato; Matsumoto, Ippei

    2011-06-15

    A 57-year-old woman with a history of diabetes mellitus underwent simultaneous pancreas-kidney transplantation. The pancreaticoduodenal graft was implanted in the right iliac fossa. The donor's portal vein was anastomosed to the recipient's inferior vena cava (IVC). Seven days after the surgery, a thrombus was detected in the graft veins. Percutaneous thrombolysis was immediately performed; however, venous congestion was still present. We therefore attempted selective embolectomy using a Fogarty Thru-Lumen Catheter. Thrombi were directed from the graft veins toward the IVC and captured in the IVC filter with complete elimination of the thrombus without any major complications. We present our techniquemore » for the successful treatment of pancreas graft thrombosis within a short time period by percutaneous selective embolectomy using a Fogarty Thru-Lumen Catheter.« less

  17. Entrapment of Guide Wire in an Inferior Vena Cava Filter: A Technique for Removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdel-Aal, Ahmed Kamel, E-mail: akamel@uabmc.edu; Saddekni, Souheil; Hamed, Maysoon Farouk

    Entrapment of a central venous catheter (CVC) guide wire in an inferior vena cava (IVC) filter is a rare, but reported complication during CVC placement. With the increasing use of vena cava filters (VCFs), this number will most likely continue to grow. The consequences of this complication can be serious, as continued traction upon the guide wire may result in filter dislodgement and migration, filter fracture, or injury to the IVC. We describe a case in which a J-tipped guide wire introduced through a left subclavian access without fluoroscopic guidance during CVC placement was entrapped at the apex of anmore » IVC filter. We describe a technique that we used successfully in removing the entrapped wire through the left subclavian access site. We also present simple useful recommendations to prevent this complication.« less

  18. Embolization of Inferior Vena Cava Filter Tyne and Right Ventricular Perforation: A Cardiac Missile.

    PubMed

    Ollila, Thomas; Naeem, Syed; Poppas, Athena; McKendall, George; Ehsan, Afshin

    2016-12-01

    Inferior vena cava (IVC) filter is a medical device placed in patients with proven pulmonary embolism or those with risk of embolization. Although many IVC filters are designed for removal after patient recovery, in many instances they are never retrieved. We present a case of a 22-year-old woman who underwent placement of an IVC filter as a prophylactic measure following a C-6 spinal injury that rendered her a quadriplegic. A tyne from the filter later fractured and embolized to the right ventricle, leading to perforation and subsequent large symptomatic pericardial effusion. The tyne was retrieved through a subxiphoid pericardial window, and the patient had an uneventful recovery. She later underwent retrieval of the entire filter. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Management of acute lower extremity deep venous thrombosis in a patient with duplicated inferior vena cava and contraindication to anticoagulation: case and review of the literature.

    PubMed

    Patel, Shrinil; Cheema, Anmol; Karawadia, Tejas; Carson, Michael

    2018-06-04

    Duplication of the inferior vena cava (DIVC) is an uncommon embryological anatomic phenomenon.We report a 63-year-old woman with extensive right leg deep vein thrombosis who required an IVC filter due to contraindications for anticoagulation, but was found to have DIVC which required the placement of two IVC filters with good result. This report will review and summarise past reports of DIVC management to provide a guide for future clinicians, and review the embryological development, diagnosis and IVC filter placement options as they are based on the type of anatomic malformation encountered. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Iodine I-131 With or Without Selumetinib in Treating Patients With Recurrent or Metastatic Thyroid Cancer

    ClinicalTrials.gov

    2018-05-15

    Metastatic Thyroid Gland Carcinoma; Poorly Differentiated Thyroid Gland Carcinoma; Recurrent Thyroid Gland Carcinoma; Stage IV Thyroid Gland Follicular Carcinoma; Stage IV Thyroid Gland Papillary Carcinoma; Stage IVA Thyroid Gland Follicular Carcinoma; Stage IVA Thyroid Gland Papillary Carcinoma; Stage IVB Thyroid Gland Follicular Carcinoma; Stage IVB Thyroid Gland Papillary Carcinoma; Stage IVC Thyroid Gland Follicular Carcinoma; Stage IVC Thyroid Gland Papillary Carcinoma

  1. [Crops: Classifying, Selecting, Harvesting, Grading, and Packing.] Student Materials. V.A. III. [IV-B-1 through IV-B-2; IV-C-1 through IV-C-2].

    ERIC Educational Resources Information Center

    Texas A and M Univ., College Station. Vocational Instructional Services.

    Part of a series of eight student learning modules in vocational agriculture, this booklet deals with crop-related activities. The first section is on harvesting methods and equipment. The following portions address the handling, grading, and packing of crops; and the classification and selection of fruits, vegetables, and ornamental plants. There…

  2. Predictors of Mortality in Patients with Penetrating Inferior Vena Cava Injuries Surviving to the Operating Room.

    PubMed

    Maciel, James D; Plurad, David; Gifford, Edward; deVirgilio, Christian; Koopmann, Matt; Neville, Angela; Putnam, Brant; Kim, Dennis Y

    2015-10-01

    Inferior vena cava (IVC) injuries are associated with significant morbidity and mortality. To identify clinical factors associated with mortality in patients undergoing operative intervention for penetrating IVC injuries, a retrospective review of 98 patients was performed, excluding blunt injuries (n = 20) and deaths before surgery (n = 16). The overall mortality was 58 per cent. Nonsurvivors more commonly presented with hypotension (50% vs 23%, P = 0.03) and underwent resuscitative thoracotomy more frequently (42% vs 4%, P = 0.01). Retrohepatic injuries were more common among nonsurvivors (P = 0.04). There was no difference in the use of ligation (7% vs 17%, P = 0.29) or the massive transfusion protocol (35% vs 25%, P = 0.41). On multivariate analysis, after controlling for mechanism of injury, admission hypotension, Glasgow Coma Scale score , preoperative cumulative fluids, resuscitative thoracotomy , absence of spontaneous tamponade, and location of IVC injury, the only independent predictor of mortality was the absence of spontaneous tamponade at the time of laparotomy (odds ratio = 5.4, 95% confidence interval: 1.11-25.95; P = 0.04). Penetrating IVC injuries continue to be associated with a high mortality, particularly among patients with free intraabdominal hemorrhage at laparotomy. Large multicenter studies are required to define the optimal resuscitative and operative management techniques in these severely injured patients.

  3. Prepare to Care, A Supported Self-Management Intervention for Head and Neck Cancer CaregiversHead and Neck Cancer

    ClinicalTrials.gov

    2018-04-26

    Caregiver; Malignant Head and Neck Neoplasm; Paranasal Sinus Squamous Cell Carcinoma; Salivary Gland Squamous Cell Carcinoma; Stage I Hypopharyngeal Squamous Cell Carcinoma; Stage I Laryngeal Squamous Cell Carcinoma; Stage I Lip and Oral Cavity Squamous Cell Carcinoma; Stage I Oropharyngeal Squamous Cell Carcinoma; Stage II Hypopharyngeal Squamous Cell Carcinoma; Stage II Laryngeal Squamous Cell Carcinoma; Stage II Lip and Oral Cavity Squamous Cell Carcinoma; Stage II Oropharyngeal Squamous Cell Carcinoma; Stage III Hypopharyngeal Squamous Cell Carcinoma; Stage III Laryngeal Squamous Cell Carcinoma; Stage III Lip and Oral Cavity Squamous Cell Carcinoma; Stage III Oropharyngeal Squamous Cell Carcinoma; Stage IV Hypopharyngeal Squamous Cell Carcinoma; Stage IV Laryngeal Squamous Cell Carcinoma; Stage IV Lip and Oral Cavity Squamous Cell Carcinoma; Stage IV Oropharyngeal Squamous Cell Carcinoma; Stage IVA Hypopharyngeal Squamous Cell Carcinoma; Stage IVA Laryngeal Squamous Cell Carcinoma; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVA Oropharyngeal Squamous Cell Carcinoma; Stage IVB Hypopharyngeal Squamous Cell Carcinoma; Stage IVB Laryngeal Squamous Cell Carcinoma; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVB Oropharyngeal Squamous Cell Carcinoma; Stage IVC Hypopharyngeal Squamous Cell Carcinoma; Stage IVC Laryngeal Squamous Cell Carcinoma; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVC Oropharyngeal Squamous Cell Carcinoma

  4. Validation of a computerized technique for automatically tracking and measuring the inferior vena cava in ultrasound imagery.

    PubMed

    Bellows, Spencer; Smith, Jordan; Mcguire, Peter; Smith, Andrew

    2014-01-01

    Accurate resuscitation of the critically-ill patient using intravenous fluids and blood products is a challenging, time sensitive task. Ultrasound of the inferior vena cava (IVC) is a non-invasive technique currently used to guide fluid administration, though multiple factors such as variable image quality, time, and operator skill challenge mainstream acceptance. This study represents a first attempt to develop and validate an algorithm capable of automatically tracking and measuring the IVC compared to human operators across a diverse range of image quality. Minimal tracking failures and high levels of agreement between manual and algorithm measurements were demonstrated on good quality videos. Addressing problems such as gaps in the vessel wall and intra-lumen speckle should result in improved performance in average and poor quality videos. Semi-automated measurement of the IVC for the purposes of non-invasive estimation of circulating blood volume poses challenges however is feasible.

  5. CT-guided percutaneous fine-needle aspiration biopsy of the inferior vena cava wall: a posterior coaxial approach.

    PubMed

    Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L

    2010-02-01

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.

  6. CT-Guided Percutaneous Fine-Needle Aspiration Biopsy of the Inferior Vena Cava Wall: A Posterior Coaxial Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kos, Sebastian, E-mail: skos@gmx.de; Bilecen, Deniz; Baumhoer, Daniel

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of themore » patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.« less

  7. Supra hepatic inferior vena cava and right atrial thrombosis following a traffic car crash.

    PubMed

    Sabzi, Feridoun; Karim, Hosein; Haghi, Marjan

    2016-07-01

    We present a case of nephrotic syndrome associated with right atrial and supra hepatic vein part of inferior vena caval thrombosis. This patient presented with dyspena, lower extremity edema and back pain after a vehicle accident and blunt trauma to the abdomen. Trauma should be considered not only as a thrombophilic pre-disposition, but also as a predisposing factor to IVC endothelium injury and thrombosis formation. Echocardiography revealed supra hepatic vein IVC thrombosis floating to the right atrium. A C-T scan with contrast also showed pulmonary artery emboli to the left upper lobe. With open heart surgery, the right atrial and IVC clot were extracted and the main left and right pulmonary arteries were evaluated for possible clot lodging. The patient had an uneventful postoperative recovery and thrombosis has not reoccurred with periodical follow-up examinations. © 2016 KUMS, All rights reserved.

  8. Lenvatinib and Pembrolizumab in DTC

    ClinicalTrials.gov

    2018-05-21

    Columnar Cell Variant Thyroid Gland Papillary Carcinoma; Follicular Variant Thyroid Gland Papillary Carcinoma; Poorly Differentiated Thyroid Gland Carcinoma; Recurrent Thyroid Gland Carcinoma; Stage III Differentiated Thyroid Gland Carcinoma AJCC v7; Stage III Thyroid Gland Follicular Carcinoma AJCC v7; Stage III Thyroid Gland Papillary Carcinoma AJCC v7; Stage IV Thyroid Gland Follicular Carcinoma AJCC v7; Stage IV Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVA Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVA Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVA Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVB Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVB Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVB Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVC Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVC Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVC Thyroid Gland Papillary Carcinoma AJCC v7; Tall Cell Variant Thyroid Gland Papillary Carcinoma; Thyroid Gland Oncocytic Follicular Carcinoma

  9. Study on virtual instrument developing system based on intelligent virtual control

    NASA Astrophysics Data System (ADS)

    Tang, Baoping; Cheng, Fabin; Qin, Shuren

    2005-01-01

    The paper introduces a non-programming developing system of a virtual instument (VI), i.e., a virtual measurement instrument developing system (VMIDS) based on intelligent virtual control (IVC). The background of the IVC-based VMIDS is described briefly, and the hierarchical message bus (HMB)-based software architecture of VMIDS is discussed in detail. The three parts and functions of VMIDS are introduced, and the process of non-programming developing VI is further described.

  10. Application of an Adaptive Control Grid Interpolation Technique to Morphological Vascular Reconstruction: A Component of a Comprehensive Surgical Planning and Evaluation Tool

    DTIC Science & Technology

    2001-10-25

    a lateral tunnel through the right atrium connecting the inferior vena cava with the RPA. The procedure results in a complete bypass of the right...IVC SVC RPA LPA SVC: superior vena cava IVC: inferior vena cava RPA: right pulmonary artery LPA: left pulmonary artery...Abstract – The total cavopulmonary connection (TCPC) is a palliative surgical repair performed on children with a single ventricle (SV

  11. Can intravenous conscious sedation with midazolam be effective at facilitating surgical dentistry in adolescent orthodontic patients? - A service evaluation

    PubMed Central

    Stamp, A.J.; Dorman, M.L.; Vernazza, C.R.; Deeming, G.; Reid, C.; Wilson, K.E.; Girdler, N.M.

    2017-01-01

    Background Surgical dentistry during orthodontic care often occurs in adolescence and may involve surgical removal or exposure of teeth. The invasive nature of treatment, combined with dental anxiety, means care is often provided under GA. Best-practice guidelines however endorse conscious sedation as an alternative, where appropriate. Although a limited number of studies have shown safe and effective use of intravenous conscious sedation (IVCS) with midazolam in this cohort, robust evidence to support routine its use is lacking. Aim To assess whether IVCS with midazolam can effectively facilitate surgical dentistry in adolescent orthodontic patients in primary care. Method A retrospective service evaluation was undertaken reviewing clinical records of adolescents (aged 12-15 years) undergoing surgical exposure and/or surgical removal of teeth under IVCS midazolam. Results A total of 174 adolescents (mean age 14.2 years) attended for treatment between 2009 and 2015. Of these adolescent, 98.9% (n=172) allowed cannulation with all surgical dentistry completed during a single visit. Midazolam dose ranged from 2-7mg with 79.1% patients having good or excellent co-operation and three minor adverse events occurring. Conclusion This service evaluation shows IVCS midazolam can effectively facilitate surgical orthodontics in carefully selected adolescents. There is however a distinct need to further explore potential for this technique to provide a viable alternative to GA. PMID:28127013

  12. Thrombosis of the inferior vena cava and malignant disease.

    PubMed

    Kraft, Christiane; Schuettfort, Gundolf; Weil, Yvonne; Tirneci, Vanessa; Kasper, Alexander; Haberichter, Barbara; Schwonberg, Jan; Schindewolf, Marc; Lindhoff-Last, Edelgard; Linnemann, Birgit

    2014-09-01

    Inferior vena cava thrombosis (IVCT) is a rare event, and studies detailing its underlying aetiologies are scarce. One hundred and forty-one IVCT patients (57% females, median age 47 years) were analysed with a focus on malignancy-related thrombosis and compared with 141 age- and sex-matched control patients with isolated lower-extremity deep vein thrombosis. Malignancies were more prevalent among IVCT patients compared with the control group (39% vs. 7.8%; P<0.001). Malignancy-related IVCT more frequently involved the suprarenal and hepatic segments of the IVC and extended more often to the right atrium than IVCT did in non-cancer patients. Among IVCT patients with malignancies, renal cell carcinoma (38%) and other malignancies of the genitourinary tract (25%) were the most common tumours. Analysis of the underlying pathological mechanisms of malignancy-related thrombosis identified external compression of the IVC by tumour masses in 9 cases (16%), and progression of malignancy into the IVC (so-called "tumour thrombosis") in 24 cases (44%). The remaining 22 cases (40%) were attributed to malignancy-related hypercoagulability and the presence of additional venous thromboembolism risk factors, such as previous surgery, immobilisation, or chemotherapy. Malignancies substantially contribute to the risk of thrombosis involving the IVC. Tumour invasion, especially in cases of renal cell cancer and malignancy-related hypercoagulability are major triggering factors for thrombogenesis. Copyright © 2014. Published by Elsevier Ltd.

  13. Inferior vena cava thrombosis and its relationship with the JAK2V617F mutation and chronic myeloproliferative disease.

    PubMed

    Linnemann, Birgit; Kraft, Christiane; Roskos, Martin; Zgouras, Dimitrios; Lindhoff-Last, Edelgard

    2012-06-01

    Splanchnic vein thrombosis (SVT) is a typical manifestation of polycythaemia vera (PV) or essential thrombocythaemia (ET). The recently discovered JAK2V617F somatic mutation is closely associated with chronic myeloproliferative disease (CMD). We investigated whether thrombosis involving the inferior vena cava (IVC) is also related to the JAK2V617F mutation or CMD. Blood samples were obtained from 40 IVC thrombosis patients. Fifty-three patients with isolated lower extremity deep vein thrombosis (LE-DVT) and 20 SVT patients served as controls. The presence of the JAK2V617F mutation was assessed by real-time polymerase chain reaction (RT-PCR). The JAK2V617F allele was not detected in any of the IVC thrombosis patients but was detected in one patient (2%) with isolated LE-DVT. However, the mutation-carrying patient did not exhibit symptoms of CMD. Even after an observation period of 30months, the patient's complete blood cell count did not exhibit any pathology. In contrast, the JAK2V617F allele was detected in four patients with SVT (20%) and CMD. According to our data, there is no evidence that IVC thrombosis is associated with the JAK2V617F mutation or the presence of chronic myeloproliferative disease. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Ficlatuzumab With or Without Cetuximab in Treating Patients With Cetuximab-Resistant, Recurrent or Metastatic Head and Neck Squamous Cell Carcinoma

    ClinicalTrials.gov

    2018-02-02

    Head and Neck Basaloid Carcinoma; Recurrent Head and Neck Squamous Cell Carcinoma; Recurrent Oropharyngeal Squamous Cell Carcinoma; Squamous Cell Carcinoma of Unknown Primary Origin; Stage IV Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IV Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IV Nasopharyngeal Keratinizing Squamous Cell Carcinoma AJCC v7; Stage IV Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVA Nasopharyngeal Keratinizing Squamous Cell Carcinoma AJCC v7; Stage IVA Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVB Nasopharyngeal Keratinizing Squamous Cell Carcinoma AJCC v7; Stage IVB Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVC Nasopharyngeal Keratinizing Squamous Cell Carcinoma AJCC v7; Stage IVC Oropharyngeal Squamous Cell Carcinoma AJCC v7; Head and Neck Cancer; Oropharyngeal Cancer; HNSCC

  15. Can intravenous conscious sedation with midazolam be effective at facilitating surgical dentistry in adolescent orthodontic patients? A service evaluation.

    PubMed

    Stamp, A J; Dorman, M L; Vernazza, C R; Deeming, G; Reid, C; Wilson, K E; Girdler, N M

    2017-01-27

    Background Surgical dentistry during orthodontic care often occurs in adolescence and may involve surgical removal or exposure of teeth. The invasive nature of treatment, combined with dental anxiety, means care can often be provided under general anaesthesia (GA). Best-practice guidelines however endorse conscious sedation as an alternative, where appropriate. Although a limited number of studies have shown safe and effective use of intravenous conscious sedation (IVCS) with midazolam in this cohort, robust evidence to support routine use is lacking. Aim To assess whether IVCS with midazolam can effectively facilitate surgical dentistry in adolescent orthodontic patients in primary care.Method A retrospective service evaluation was undertaken reviewing clinical records of adolescents (aged 12-15 years) undergoing surgical exposure and/or surgical removal of teeth under IVCS with midazolam.Results A total of 174 adolescents (mean age 14.2 years) attended for treatment between 2009 and 2015. Of these adolescents, 98.9% (N = 172) allowed cannulation, with all surgical dentistry completed during a single visit. Midazolam dose ranged from 2-7 mg with 79.1% of patients having good or excellent cooperation and three minor adverse events occurring.Conclusion This service evaluation shows IVCS with midazolam can effectively facilitate surgical orthodontics in carefully selected adolescents. There is however a distinct need to further explore potential for this technique to provide a viable alternative to GA.

  16. Impact of Chronic Rheumatic Valve Diseases on Large Vessels.

    PubMed

    Altunbas, Gokhan; Yuce, Murat; Ozer, Hasan O; Davutoglu, Vedat; Ercan, Suleyman; Kizilkan, Nese; Bilici, Muhammet

    2016-01-01

    BACKGROUND AND AIM OF STUDY: Rheumatic valvular heart disease, which remains a common health problem in developing countries, has numerous consequences on the heart chambers and circulation. The study aim was to investigate the effects of chronic rheumatic valve disease on the diameters of the descending aorta (DA) and inferior vena cava (IVC). METHODS: A total of 88 patients with echocardiographically documented rheumatic valvular heart disease and 112 healthy controls were enrolled into the study. All patients underwent detailed echocardiographic examinations, while their height and body weight were recorded and adjusted to their body surface area. RESULTS: The most common involvement was mitral valve disease, followed by aortic valve disease and tricuspid valve disease. The mean diameter of the DA (indexed to BSA) was 1.79 ± 0.49 cm for patients and 1.53 ± 0.41 for controls (p <0.001). The mean diameter of the IVC (indexed to BSA) was 1.69 ± 0.73 for patients and 1.38 ± 0.35 cm for controls (p <0.001). There was a significant positive correlation between mitral valve mean gradient and IVC diameter (p = 0.01, r = 0.18). There were also strong associations between the mitral valve area and the diameters of the DA (p = 0.001, r = -0.239) and IVC (p <0.001, r = -0.246). CONCLUSION: Rheumatic valve disease, especially mitral stenosis, was closely related to remodeling of the great vessels.

  17. A Framework for Quantifying Measurement Uncertainties and Uncertainty Propagation in HCCI/LTGC Engine Experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petitpas, Guillaume; McNenly, Matthew J.; Whitesides, Russell A.

    In this study, a framework for estimating experimental measurement uncertainties for a Homogenous Charge Compression Ignition (HCCI)/Low-Temperature Gasoline Combustion (LTGC) engine testing facility is presented. Detailed uncertainty quantification is first carried out for the measurement of the in-cylinder pressure, whose variations during the cycle provide most of the information for performance evaluation. Standard uncertainties of other measured quantities, such as the engine geometry and speed, the air and fuel flow rate and the intake/exhaust dry molar fractions are also estimated. Propagating those uncertainties using a Monte Carlo simulation and Bayesian inference methods then allows for estimation of uncertainties of themore » mass-average temperature and composition at IVC and throughout the cycle; and also of the engine performances such as gross Integrated Mean Effective Pressure, Heat Release and Ringing Intensity. Throughout the analysis, nominal values for uncertainty inputs were taken from a well-characterized engine test facility. However, the analysis did not take into account the calibration practice of experiments run in that facility and the resulting uncertainty values are therefore not indicative of the expected accuracy of those experimental results. A future study will employ the methodology developed here to explore the effects of different calibration methods on the different uncertainty values in order to evaluate best practices for accurate engine measurements.« less

  18. A Framework for Quantifying Measurement Uncertainties and Uncertainty Propagation in HCCI/LTGC Engine Experiments

    DOE PAGES

    Petitpas, Guillaume; McNenly, Matthew J.; Whitesides, Russell A.

    2017-03-28

    In this study, a framework for estimating experimental measurement uncertainties for a Homogenous Charge Compression Ignition (HCCI)/Low-Temperature Gasoline Combustion (LTGC) engine testing facility is presented. Detailed uncertainty quantification is first carried out for the measurement of the in-cylinder pressure, whose variations during the cycle provide most of the information for performance evaluation. Standard uncertainties of other measured quantities, such as the engine geometry and speed, the air and fuel flow rate and the intake/exhaust dry molar fractions are also estimated. Propagating those uncertainties using a Monte Carlo simulation and Bayesian inference methods then allows for estimation of uncertainties of themore » mass-average temperature and composition at IVC and throughout the cycle; and also of the engine performances such as gross Integrated Mean Effective Pressure, Heat Release and Ringing Intensity. Throughout the analysis, nominal values for uncertainty inputs were taken from a well-characterized engine test facility. However, the analysis did not take into account the calibration practice of experiments run in that facility and the resulting uncertainty values are therefore not indicative of the expected accuracy of those experimental results. A future study will employ the methodology developed here to explore the effects of different calibration methods on the different uncertainty values in order to evaluate best practices for accurate engine measurements.« less

  19. Optimal vitrification protocol for mouse ovarian tissue cryopreservation: effect of cryoprotective agents and in vitro culture on vitrified-warmed ovarian tissue survival.

    PubMed

    Youm, Hye Won; Lee, Jung Ryeol; Lee, Jaewang; Jee, Byung Chul; Suh, Chang Suk; Kim, Seok Hyun

    2014-04-01

    What is the optimal vitrification protocol according to the cryoprotective agent (CPA) for ovarian tissue (OT) cryopreservation? The two-step protocol with 7.5% ethylene glycol (EG) and 7.5% dimethyl sulfoxide (DMSO) for 10 min then 20% EG, 20% DMSO and 0.5 M sucrose for 5 min showed the best results in mouse OT vitrification. Establishing the optimal cryopreservation protocol is one of the most important steps to improve OT survival. However, only a few studies have compared vitrification protocols with different CPAs and investigated the effect of in vitro culture (IVC) on vitrified-warmed OT survival. Some recent papers proposed that a combination of CPAs has less toxicity than one type of CPA. However, the efficacy of different types and concentrations of CPA are not yet well documented. A total of 644 ovaries were collected from 4-week-old BDF1 mice, of which 571 ovaries were randomly assigned to 8 groups and vitrified using different protocols according to CPA composition and the remaining 73 ovaries were used as controls. After warming, each of the eight groups of ovaries was further randomly divided into four subgroups and in vitro cultured for 0, 0.5, 2 and 4 h, respectively. Ovaries of the best two groups among the eight groups were autotransplanted after IVC. The CPA solutions for the eight groups were composed of EDS, ES, ED, EPS, EF, EFS, E and EP, respectively (E, EG; D, DMSO; P, propanediol; S, sucrose; F, Ficoll). The IVC medium was composed of α-minimal essential medium, 10% fetal bovine serum and 10 mIU/ml follicle-stimulating hormone (FSH). Autotransplantation of vitrified-warmed OTs after IVC (0 to 4 h) using the EDS or ES protocol was performed, and the grafts were recovered after 3 weeks. Ovarian follicles were assessed for morphology, apoptosis, proliferation and FSH level. The percentages of the morphologically intact (G1) and apoptotic follicles in each group at 0, 0.5, 2 and 4 h of IVC were compared. For G1 follicles at 0 and 4 h of IVC, the EDS group showed the best results at 63.8 and 46.6%, respectively, whereas the EP group showed the worst results at 42.2 and 12.8%, respectively. The apoptotic follicle ratio was lowest in the EDS group at 0 h (8.1%) and 0.5 h (12.7%) of IVC. All of the eight groups showed significant decreases in G1 follicles and increases in apoptotic follicles as IVC duration progressed. After autotransplantation, the EDS 0 h group showed a significantly higher G1 percentage (84.9%) than did the other groups (42.4-58.8%), while only the ES 4 h group showed a significant decrease in the number of proliferative cells (80.6%, 87.6-92.9%). However, no significant differences in apoptotic rates and FSH levels were observed between the groups after autotransplantation. The limitation of this study was the absence of in vitro fertilization using oocytes obtained from OT grafts, which should be performed to confirm the outcomes of ovarian cryopreservation and transplantation. We compared eight vitrification protocols according to CPA composition and found the EDS protocol to be the optimal method among them. The data presented herein will help improve OT cryopreservation protocols for humans or other animals.

  20. Alginate beads as a tool to handle, cryopreserve and culture isolated human primordial/primary follicles.

    PubMed

    Camboni, A; Van Langendonckt, A; Donnez, J; Vanacker, J; Dolmans, M M; Amorim, C A

    2013-08-01

    One major concern of grafting cryopreserved ovarian tissue to restore fertility in cancer patients is the possibility of reintroducing tumor cells. Cryopreservation of isolated primordial/primary follicles (PFs) may circumvent this problem. The aim of our work was to compare dimethyl sulfoxide (ME2SO) and ethylene glycol (EG) as cryoprotectants (CPAs) for slow-freezing of isolated human PFs in alginate. Ovarian biopsies from four women were processed for follicle isolation. PFs were embedded in alginate (5-15 per group). Follicles were frozen-thawed using 1.4M ME2SO or 1.5M EG as CPAs. Fresh and cryopreserved isolated follicles were in vitro cultured (IVC) for 7 days. At different time periods (after isolation, cryopreservation and IVC), follicles were evaluated with live/dead assay (using fluorescent probes) and diameter measurement. Follicle viability was calculated according to the percentage of dead follicular cells and the presence of a live/dead oocyte. A total of 841 PFs were isolated, embedded in alginate and cryopreserved with ME2SO (n=424) or EG (n=259), or used as controls (n=158). After 7 days of IVC, a significant increase in follicle size was observed in the fresh and ME2SO groups, but not in the EG group. The percentage of totally viable PFs was not significantly different before or after seven days of culture in fresh (100% and 82%) or ME2SO (93.2% and 85.1%) tissue. The EG group showed significantly lower viability before (63.9%) and after IVC (66.2%) than the fresh and ME2SO groups. Our results show that 1.4M ME2SO yields better preservation of isolated PF viability after thawing and 7 days of IVC than 1.5M EG. Alginate constitutes an easy, safe hydrogel matrix to handle and cryopreserve isolated human follicles using ME2SO as a CPA. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Complete Circular Genome Sequence of Successful ST8/SCCmecIV Community-Associated Methicillin-Resistant Staphylococcus aureus (OC8) in Russia: One-Megabase Genomic Inversion, IS256’s Spread, and Evolution of Russia ST8-IV

    PubMed Central

    Wan, Tsai-Wen; Higuchi, Wataru; Hung, Wei-Chun; Reva, Ivan V.; Singur, Olga A.; Gostev, Vladimir V.; Sidorenko, Sergey V.; Peryanova, Olga V.; Salmina, Alla B.; Reva, Galina V.; Teng, Lee-Jene; Yamamoto, Tatsuo

    2016-01-01

    ST8/SCCmecIV community-associated methicillin-resistant Staphylococcus aureus (CA-MRSA) has been a common threat, with large USA300 epidemics in the United States. The global geographical structure of ST8/SCCmecIV has not yet been fully elucidated. We herein determined the complete circular genome sequence of ST8/SCCmecIVc strain OC8 from Siberian Russia. We found that 36.0% of the genome was inverted relative to USA300. Two IS256, oppositely oriented, at IS256-enriched hot spots were implicated with the one-megabase genomic inversion (MbIN) and vSaβ split. The behavior of IS256 was flexible: its insertion site (att) sequences on the genome and junction sequences of extrachromosomal circular DNA were all divergent, albeit with fixed sizes. A similar multi-IS256 system was detected, even in prevalent ST239 healthcare-associated MRSA in Russia, suggesting IS256’s strong transmission potential and advantage in evolution. Regarding epidemiology, all ST8/SCCmecIVc strains from European, Siberian, and Far Eastern Russia, examined had MbIN, and geographical expansion accompanied divergent spa types and resistance to fluoroquinolones, chloramphenicol, and often rifampicin. Russia ST8/SCCmecIVc has been associated with life-threatening infections such as pneumonia and sepsis in both community and hospital settings. Regarding virulence, the OC8 genome carried a series of toxin and immune evasion genes, a truncated giant surface protein gene, and IS256 insertion adjacent to a pan-regulatory gene. These results suggest that unique single ST8/spa1(t008)/SCCmecIVc CA-MRSA (clade, Russia ST8-IVc) emerged in Russia, and this was followed by large geographical expansion, with MbIN as an epidemiological marker, and fluoroquinolone resistance, multiple virulence factors, and possibly a multi-IS256 system as selective advantages. PMID:27741255

  2. A single center experience with retrievable IVC filters.

    PubMed

    Renno, Anas; Khateeb, Faisal; Kazan, Viviane; Qu, Weikai; Gollapudi, Anurekha; Aplin, Brett; Abbas, Jihad; Zelenock, Gerald; Nazzal, Munier

    2015-08-01

    To evaluate retrievable IVC filters in our institution and assess their retrieval following a well-structured follow up program. Retrospective cohort study. The medical records of patients implanted with retrievable IVC filters were reviewed. All retrievable filter insertions between July 2007 and August 2011 at our institution were reviewed. Data was analyzed for age, gender, indication, complications, retrieval rate, and brand of filter inserted. Statistical analysis was done using SPSS software v19. Chi-square was used to compare discrete data and t-test for continuous data. P < 0.05 was significant. A total of 484 patients were reviewed of which 258 (53.1%) had a complete medical record. And 96 (37.2%) filters were placed as permanent at the time of insertion. An additional 40 (15.5%) filters were converted to permanent (total permanent filters 136; 52.7%). Death was reported in 26 (10%) patients and 96 (37.2%) out of the remaining 232 patients presented for potential retrieval. Also, 73 (28.2%) had an attempt to retrieve the filters, 69 (94.5%) were successful and 4 (5.4%) failed to retrieve. The remaining 23 (8.9%) patients declined retrieval. Filters studied include Celect (38%), Bard (31.4%), Option (26.2%), Tulip (4.1%), and Recovery (0.2%). Bard was more commonly used as a retrievable filter (80.9%). Retrieval on the first attempt was 90.4% (n = 66) successful. Of the remaining seven filters, three were successfully retrieved on a second attempt, and four failed to retrieve due to filter tilt. The success rates of retrieval for Celect and Tulip were significantly lower than for Bard (p = 0.04 and 0.023, respectively). Our study showed that a variety of IVC filters can be retrieved successfully with minimal complication rates. In more than half of our patients, IVC filters were used as permanent. Failure of retrieval was most frequently due to filter tilting. © The Author(s) 2014.

  3. Complications and Retrieval Data of Vena Cava Filters Based on Specific Infrarenal Location.

    PubMed

    Tullius, Thomas G; Bos, Aaron S; Patel, Mikin V; Funaki, Brian; Van Ha, Thuong G

    2018-02-01

    Although recommended placement of IVC filters is with their tips positioned at the level of the renal vein inflow, in practice, adherence is limited due to clinical situation or IVC anatomy. We seek to evaluate the indwelling and retrieval complications of IVC filters based on their specific position within the infrarenal IVC. Retrospective, single institution study of 333 consecutive infrarenal vena cava filters placed by interventional radiologists in patients with an average age of 62.2 ± 15.7 years was performed between 2013 and 2015. Primary indication was venous thromboembolic disease (n = 320, 96.1%). Filters were classified based on location of the apex below the lowest renal vein inflow on the procedural venogram: less than 1 cm (n = 180, 54.1%), 1-2 cm (n = 96, 28.8%), and greater than 2 cm (n = 57, 17.1%). Denali (n = 171, 51.4%) and Celect (n = 162, 48.6%) filters were evaluated. CT follow-up, indwelling complications, and retrieval data were obtained. Follow-up CT imaging performed for symptomatic indications occurred for 38.3% of filters placed < 1 cm below the lowest renal vein, 27.1% of filters placed 1-2 cm, and 36.8% placed > 2 cm (p = .16). There was no difference in caval strut penetration, penetration of adjacent viscera, time to penetration, filter migration, or tilt (p = .15, .27, .41, .57, .93). No filter fractures occurred. There was no difference in the incidence of breakthrough PE or complex filter retrieval (p = .83, .59). Only one retrieval failure occurred. This study suggests filter apex location within the infrarenal IVC, including placement > 2 cm below the level of the renal vein inflow, is not associated with differences in indwelling or retrieval complications. Level 3 non-randomized controlled follow-up study.

  4. Complete Circular Genome Sequence of Successful ST8/SCCmecIV Community-Associated Methicillin-Resistant Staphylococcus aureus (OC8) in Russia: One-Megabase Genomic Inversion, IS256's Spread, and Evolution of Russia ST8-IV.

    PubMed

    Wan, Tsai-Wen; Khokhlova, Olga E; Iwao, Yasuhisa; Higuchi, Wataru; Hung, Wei-Chun; Reva, Ivan V; Singur, Olga A; Gostev, Vladimir V; Sidorenko, Sergey V; Peryanova, Olga V; Salmina, Alla B; Reva, Galina V; Teng, Lee-Jene; Yamamoto, Tatsuo

    2016-01-01

    ST8/SCCmecIV community-associated methicillin-resistant Staphylococcus aureus (CA-MRSA) has been a common threat, with large USA300 epidemics in the United States. The global geographical structure of ST8/SCCmecIV has not yet been fully elucidated. We herein determined the complete circular genome sequence of ST8/SCCmecIVc strain OC8 from Siberian Russia. We found that 36.0% of the genome was inverted relative to USA300. Two IS256, oppositely oriented, at IS256-enriched hot spots were implicated with the one-megabase genomic inversion (MbIN) and vSaβ split. The behavior of IS256 was flexible: its insertion site (att) sequences on the genome and junction sequences of extrachromosomal circular DNA were all divergent, albeit with fixed sizes. A similar multi-IS256 system was detected, even in prevalent ST239 healthcare-associated MRSA in Russia, suggesting IS256's strong transmission potential and advantage in evolution. Regarding epidemiology, all ST8/SCCmecIVc strains from European, Siberian, and Far Eastern Russia, examined had MbIN, and geographical expansion accompanied divergent spa types and resistance to fluoroquinolones, chloramphenicol, and often rifampicin. Russia ST8/SCCmecIVc has been associated with life-threatening infections such as pneumonia and sepsis in both community and hospital settings. Regarding virulence, the OC8 genome carried a series of toxin and immune evasion genes, a truncated giant surface protein gene, and IS256 insertion adjacent to a pan-regulatory gene. These results suggest that unique single ST8/spa1(t008)/SCCmecIVc CA-MRSA (clade, Russia ST8-IVc) emerged in Russia, and this was followed by large geographical expansion, with MbIN as an epidemiological marker, and fluoroquinolone resistance, multiple virulence factors, and possibly a multi-IS256 system as selective advantages.

  5. Current US Military Operations and Implications for Military Surgical Training

    DTIC Science & Technology

    2010-11-01

    with most procedures encountered except nephrectomy (1.5 proce- dures per resident [PPR]), craniotomy (1.1 PPRs), inferior vena cava injury (1.1 PPRs... craniotomy , IVC injury, duodenal injury, and bladder re- pair. Residents had minimal experience with external fixa- tion of skeletal injury and...vascular injury 3.5 NR Nephrectomy 3.5 1.5 Pancreatic drainage 2.8 1.9 IVC injury 2.4 1.1 Duodenal injury 2.2 0.6 NR, procedure frequency not captured

  6. Successful living donor liver transplant in a child with Abernethy malformation with biliary atresia, ventricular septal defect and intrapulmonary shunting.

    PubMed

    Singhal, Ashish; Srivastava, Ajitabh; Goyal, Neerav; Vij, Vivek; Wadhawan, Manav; Bera, Motilal; Gupta, Subash

    2009-12-01

    Congenital portosystemic shunts are the anomalies in which the mesenteric venous drainage bypasses the liver and drains directly into the systemic circulation. This is a report of a rare case of LDLT in a four-yr old male child suffering with biliary atresia (post-failed Kasai procedure) associated with (i) a large congenital CEPSh from the spleno-mesentric confluence to the LHV, (ii) intrapulmonary shunts, (iii) perimembranous VSD. The left lobe graft was procured from the mother of the child. Recipient IVC and the shunt vessel were preserved during the hepatectomy, and the caval and shunt clamping were remarkably short while performing the HV and portal anastomosis. Post-operative course was uneventful; intrapulmonary shunts regressed within three months after transplantation and currently after 18 months following transplant child is doing well with normal liver functions. CEPSh has been extensively discussed and all the published cases of liver transplantation for CEPSh were reviewed.

  7. Inferior Vena Cava Filtration in the Management of Venous Thromboembolism: Filtering the Data

    PubMed Central

    Molvar, Christopher

    2012-01-01

    Venous thromboembolism (VTE) is a common cause of morbidity and mortality. This is especially true for hospitalized patients. Pulmonary embolism (PE) is the leading preventable cause of in-hospital mortality. The preferred method of both treatment and prophylaxis for VTE is anticoagulation. However, in a subset of patients, anticoagulation therapy is contraindicated or ineffective, and these patients often receive an inferior vena cava (IVC) filter. The sole purpose of an IVC filter is prevention of clinically significant PE. IVC filter usage has increased every year, most recently due to the availability of retrievable devices and a relaxation of thresholds for placement. Much of this recent growth has occurred in the trauma patient population given the high potential for VTE and frequent contraindication to anticoagulation. Retrievable filters, which strive to offer the benefits of permanent filters without time-sensitive complications, come with a new set of challenges including methods for filter follow-up and retrieval. PMID:23997414

  8. A rare congenital extrahepatic portosystemic shunt affecting the inferior mesenteric vein, inferior vena cava, and left ovarian vein.

    PubMed

    Takeuchi, Hajime; Takeda, Yoko; Takahashi, Miyo; Hayashi, Shogo; Fukuzawa, Yoshitaka; Nakano, Takashi

    2014-09-01

    To observe a case of congenital extrahepatic portosystemic shunt and discuss it from the embryological and clinical viewpoints. An 85-year-old female cadaver was employed for a dissection course at Aichi Medical University in 2009. There was no evidence of liver cirrhosis macroscopically or microscopically. A portosystemic shunt was observed that involved communication between the inferior mesenteric vein, inferior vena cava (IVC), and left ovarian vein by a single Y-shaped shunt vessel. To the best of our knowledge, this is the first reported case of the above-mentioned three veins being connected by a single Y-shaped shunt vessel. Considering the other venous diameters, the shunt appeared to flow into the splenic vein and IVC. It cannot be denied that this shunt may have led to hepatic encephalopathy, although the shunt effect may have been minimal. Embryological development of IVC appears to occur close to the plexus of anastomosing vitelline veins, forming the portal vein.

  9. Comparison of superior vena caval and inferior vena caval access using a radioisotope technique during normal perfusion and cardiopulmonary resuscitation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dalsey, W.C.; Barsan, W.G.; Joyce, S.M.

    1984-10-01

    Recent studies of thoracic pressure changes during external cardiopulmonary resuscitation (CPR) suggest that there may be a significant difference in the rate of delivery of intravenous drugs when they are administered through the extrathoracic inferior vena cava (IVC) rather than the intrathoracic superior vena cava (SVC). Comparison of delivery of a radionuclide given using superior and inferior vena caval access sites was made during normal blood flow and during CPR. Mean times from injection to peak emission count in each ventricle were determined. There were no significant differences between mean peak times for SVC or IVC routes during normal flowmore » or CPR. When peak times were corrected for variations in cardiac output, there were no significant differences between IVC and SVC peak times during normal flow. During CPR, however, mean left ventricular peak time, when corrected for cardiac output, was significantly shorter (P less than .05) when the SVC route was used. The mean time for the counts to reach half the ventricular peak was statistically shorter (P less than .05) in both ventricles with the SVC route during the low flow of CPR. This suggests that during CPR, increased drug dispersion may occur when drugs are infused by the IVC route and thus may modify the anticipated effect of the drug bolus. These results suggest that during CPR, both the cardiac output and the choice of venous access are important variables for drug delivery.« less

  10. The internal anatomy of the inferior vena cava with specific emphasis on the entrance of the renal, gonadal and lumbar veins.

    PubMed

    Bubb, Kathleen; du Plessis, Maira; Hage, Robert; Tubbs, R Shane; Loukas, Marios

    2016-01-01

    Major tributaries such as the renal and adrenal veins have been studied extensively; however, tributaries of the infra-renal segment of the inferior vena cava (IVC) have not been given much attention. Accurate knowledge of the anatomy of these veins is necessary for improved efficacy of surgical interventions in the retroperitoneum. The aim of this study therefore was to provide a comprehensive picture of the internal anatomy of the tributaries of the infra-renal segment of the IVC. Dissection of the posterior abdominal wall was performed on 30 formalin-fixed cadavers. Endoscopic study was carried out followed by a midline venotomy on the anterior wall of the isolated IVC, the location and orientation of its tributaries and their ostia were observed and measurements taken. The results showed that while there was great variation in the drainage pattern of the lumbar veins, most lumbar veins had ostia located between L2 and L3 vertebrae irrespective of the location of renal and gonadal tributaries. Valves were found in 81.81 % of gonadal veins, in 56.60 % of all lumbar veins and discrete ostial valves in 14.81 % of renal veins. The location of the tributaries of the IVC was correlated with the vertebral levels. Empirical data regarding their ostio-valvular complexes were established, which put into question widely accepted concept of valveless tributaries. Our results may implicate surgical procedures in and around the retroperitoneal region.

  11. Adult Wilms tumor with inferior vena cava thrombus and distal deep vein thrombosis - a case report and literature review.

    PubMed

    Ratajczyk, Krzysztof; Czekaj, Adrian; Rogala, Joanna; Kowal, Pawel

    2018-02-23

    Adult Wilms tumor (WT, nephroblastoma) is a rare, but well-described renal neoplasm. Although inferior vena cava tumor thrombosis is present in up to 10% of Wilms tumors in childhood, only few cases of this clinical manifestation in adults have been reported. To the best of our knowledge, this is the first case of adult WT infiltrating into inferior vena cava (IVC) with concomitant distal deep vein thrombosis. A 28-year-old male patient with gross hematuria and right flank pain was diagnosed with right kidney tumor penetrating to IVC. Preoperatively, acute distal thrombosis in inferior vena cava and lower extremities veins occurred. Right radical nephrectomy with tumor thrombectomy via cavotomy was performed. In order to prevent pulmonary embolism, IVC was ligated below left renal vein level. Histopathological examination revealed a triphasic nephroblastoma without anaplastic features. Postoperatively, patient was diagnosed with metastatic liver disease, which was treated with two lines of chemotherapy followed by radiotherapy with achievement of complete response. Adult WT occurs usually in young patients, under 40 years of age. Neoadjuvant chemotherapy proved to be effective in children, resulting with tumor shrinkage and venous tumor thrombus regression. Therefore, percutaneous biopsy should be always considered in young patients presenting with renal tumor invading venous system. IVC ligation is a safe treatment option in the event of complete inferior vena cava occlusion due to distal thrombosis concomitant to tumor thrombus, provided collateral venous pathways are well-developed.

  12. Intelligent viewing control for robotic and automation systems

    NASA Astrophysics Data System (ADS)

    Schenker, Paul S.; Peters, Stephen F.; Paljug, Eric D.; Kim, Won S.

    1994-10-01

    We present a new system for supervisory automated control of multiple remote cameras. Our primary purpose in developing this system has been to provide capability for knowledge- based, `hands-off' viewing during execution of teleoperation/telerobotic tasks. The reported technology has broader applicability to remote surveillance, telescience observation, automated manufacturing workcells, etc. We refer to this new capability as `Intelligent Viewing Control (IVC),' distinguishing it from a simple programmed camera motion control. In the IVC system, camera viewing assignment, sequencing, positioning, panning, and parameter adjustment (zoom, focus, aperture, etc.) are invoked and interactively executed by real-time by a knowledge-based controller, drawing on a priori known task models and constraints, including operator preferences. This multi-camera control is integrated with a real-time, high-fidelity 3D graphics simulation, which is correctly calibrated in perspective to the actual cameras and their platform kinematics (translation/pan-tilt). Such merged graphics- with-video design allows the system user to preview and modify the planned (`choreographed') viewing sequences. Further, during actual task execution, the system operator has available both the resulting optimized video sequence, as well as supplementary graphics views from arbitrary perspectives. IVC, including operator-interactive designation of robot task actions, is presented to the user as a well-integrated video-graphic single screen user interface allowing easy access to all relevant telerobot communication/command/control resources. We describe and show pictorial results of a preliminary IVC system implementation for telerobotic servicing of a satellite.

  13. Combined liver resection and reconstruction of the supra-renal vena cava: the Paul Brousse experience.

    PubMed

    Azoulay, Daniel; Andreani, Paola; Maggi, Umberto; Salloum, Chadi; Perdigao, Fabiano; Sebagh, Mylène; Lemoine, Antoinette; Adam, René; Castaing, Denis

    2006-07-01

    Liver tumors with inferior vena cava (IVC) involvement may require combined resection of the liver and IVC. This approach, with its high surgical risks and poor long-term prognosis, was precluded until the development of neoadjuvant chemotherapy, portal vein embolization, reinforced vascular prostheses, and technical advances in liver transplantation. We reviewed 22 cases of hepatectomy with retrohepatic IVC resection and reconstruction. The patients had a median age of 51.5 years (range, 32.8-75.3 years). Indications for resection were: liver metastases (n = 9), cholangiocarcinoma (n = 8), hepatocellular carcinoma (n = 2), other cancers (n = 3). The liver resections carried out included 18 first, 3 second, and one third hepatectomy. Segment 1 (caudate lobe) was included in the specimen in 19 cases (86%). Resection concerned 1 to 6 liver segments (median = 5.0). Vascular control was achieved by vascular exclusion of the liver preserving the caval flow (n = 1), standard vascular exclusion of the liver (n = 12), in situ cold perfusion of the liver (n = 9). Ex situ surgery was not necessary in any case. Venovenous bypass was used in 12 cases. The IVC was reconstructed with a ringed Gore-Tex tube graft (n = 10), primarily (n = 8), or by caval plasty (n = 4). A main hepatic vein was reimplanted in 6 cases: into the native IVC (n = 4) or into a Gore-Tex tube graft (n = 2). One patient died (4.5%) due to catheter infection, 7 days after in situ cold perfusion with replacement of the vena cava. Eight patients (36%) had no complications and 14 patients (64%) had 23 complications. In all but 1 case, the complications were transient and successfully controlled. The patients stayed in intensive care for 3.3 +/- 2.0 days and in the hospital for 17.7 +/- 7.8 days. All vascular reconstructions were patent at last follow-up. With median follow-up of 19 months, 10 patients died of tumor recurrence and eleven were alive with (n = 5) or without (n = 6) disease. Actuarial 1-, 3-, and 5-year survival rates were 81.8%, 38.3%, and 38.3%, respectively. IVC resection and reconstruction combined with liver resection can be safely performed in selected patients. The lack of alternative treatments and the spontaneous poor prognosis justify this approach, provided that surgery is carried out at a center specialized in both liver surgery and liver transplantation. The development of adjuvant chemotherapy regimens is required to improve the long-term results of this salvage surgery.

  14. Transoral Robotic Surgery in Treating Patients With Benign or Malignant Tumors of the Head and Neck

    ClinicalTrials.gov

    2018-06-26

    Recurrent Adenoid Cystic Carcinoma of the Oral Cavity; Recurrent Mucoepidermoid Carcinoma of the Oral Cavity; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Stage 0 Hypopharyngeal Cancer; Stage 0 Laryngeal Cancer; Stage 0 Lip and Oral Cavity Cancer; Stage I Adenoid Cystic Carcinoma of the Oral Cavity; Stage I Mucoepidermoid Carcinoma of the Oral Cavity; Stage I Squamous Cell Carcinoma of the Hypopharynx; Stage I Squamous Cell Carcinoma of the Larynx; Stage I Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage I Verrucous Carcinoma of the Larynx; Stage I Verrucous Carcinoma of the Oral Cavity; Stage II Adenoid Cystic Carcinoma of the Oral Cavity; Stage II Mucoepidermoid Carcinoma of the Oral Cavity; Stage II Squamous Cell Carcinoma of the Hypopharynx; Stage II Squamous Cell Carcinoma of the Larynx; Stage II Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage II Verrucous Carcinoma of the Larynx; Stage II Verrucous Carcinoma of the Oral Cavity; Stage III Adenoid Cystic Carcinoma of the Oral Cavity; Stage III Mucoepidermoid Carcinoma of the Oral Cavity; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IVA Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVA Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVB Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVC Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer

  15. Perivascular epithelioid cell tumour (PEComa) of the inferior vena cava presenting as an adrenal mass.

    PubMed

    Kumar, Santosh; Lal, Anupam; Acharya, Naveen; Sharma, Varun

    2010-03-16

    A 54-year-old woman had a mass located in the right suprarenal area. On imaging, this mass appeared to be infiltrating the inferior vena cava (IVC). Exploratory laparotomy was undertaken and excision of the tumour was done with the sleeve of the involved IVC. The mass turned out to be a perivascular epithelioid cell tumour (PEComa) on histopathological examination. This report describes previously reported cases of PEComa in brief and highlights the problems associated with the management of this tumour.

  16. Perivascular epithelioid cell tumour (PEComa) of the inferior vena cava presenting as an adrenal mass

    PubMed Central

    Lal, Anupam; Acharya, Naveen; Sharma, Varun

    2010-01-01

    Abstract A 54-year-old woman had a mass located in the right suprarenal area. On imaging, this mass appeared to be infiltrating the inferior vena cava (IVC). Exploratory laparotomy was undertaken and excision of the tumour was done with the sleeve of the involved IVC. The mass turned out to be a perivascular epithelioid cell tumour (PEComa) on histopathological examination. This report describes previously reported cases of PEComa in brief and highlights the problems associated with the management of this tumour. PMID:20233679

  17. Trametinib in Increasing Tumoral Iodine Incorporation in Patients With Recurrent or Metastatic Thyroid Cancer

    ClinicalTrials.gov

    2018-04-18

    BRAF Gene Mutation; Poorly Differentiated Thyroid Gland Carcinoma; RAS Family Gene Mutation; Recurrent Thyroid Gland Carcinoma; Stage IV Thyroid Gland Follicular Carcinoma AJCC v7; Stage IV Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVA Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVA Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVB Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVB Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVC Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVC Thyroid Gland Papillary Carcinoma AJCC v7

  18. Individualized treatment in stage IVC nasopharyngeal carcinoma.

    PubMed

    Chan, Oscar S H; Ngan, Roger K C

    2014-09-01

    The stage IVC nasopharyngeal carcinoma is a catch-all entity covering minute solitary metastasis to bulky disseminated disease. Prognosis varies greatly within this stage group. A subset of patients with oligometastases may benefit from aggressive local ablative therapy. Meanwhile, in multiple metastatic diseases, customizing conventional cytotoxics basing on individual tumor characteristics and previous chemotherapy responses can be a new direction to improve therapeutic results. Prognostic models built on clinical features and genomic profiles can be utilized to stratify different risk groups and tailor therapy schemes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Retrievable Inferior Vena Cava Filters for Venous Thromboembolism

    PubMed Central

    Win, Lei Lei

    2013-01-01

    Inferior vena cava (IVC) filters are used as an alternative to anticoagulants for prevention of fatal pulmonary embolism (PE) in venous thromboembolic disorders. Retrievable IVC filters have become an increasingly attractive option due to the long-term risks of permanent filter placement. These devices are shown to be technically feasible in insertion and retrieval percutaneously while providing protection from PE. Nevertheless, there are complications and failed retrievals with these retrievable filters. The aim of the paper is to review the retrievable filters and their efficacy, safety, and retrievability. PMID:24967292

  20. Olfactory Training in Improving Sense of Smell After Radiation Therapy in Patients With Paranasal Sinus or Nasopharyngeal Cancer

    ClinicalTrials.gov

    2017-07-11

    Stage 0 Nasopharyngeal Carcinoma; Stage 0 Paranasal Sinus Cancer; Stage I Nasopharyngeal Carcinoma; Stage I Paranasal Sinus Cancer; Stage II Nasopharyngeal Carcinoma; Stage II Paranasal Sinus Cancer; Stage IIA Nasopharyngeal Carcinoma; Stage IIB Nasopharyngeal Carcinoma; Stage III Nasopharyngeal Carcinoma; Stage III Paranasal Sinus Cancer; Stage IV Nasopharyngeal Carcinoma; Stage IV Paranasal Sinus Cancer; Stage IVA Nasopharyngeal Carcinoma; Stage IVA Paranasal Sinus Cancer; Stage IVB Nasopharyngeal Carcinoma; Stage IVB Paranasal Sinus Cancer; Stage IVC Nasopharyngeal Carcinoma; Stage IVC Paranasal Sinus Cancer

  1. Akt Inhibitor MK2206 in Treating Patients With Progressive, Recurrent, or Metastatic Adenoid Cyst Carcinoma

    ClinicalTrials.gov

    2018-03-21

    Recurrent Oral Cavity Adenoid Cystic Carcinoma; Recurrent Salivary Gland Carcinoma; Salivary Gland Adenoid Cystic Carcinoma; Stage IVA Major Salivary Gland Cancer AJCC v7; Stage IVA Oral Cavity Adenoid Cystic Carcinoma AJCC v6 and v7; Stage IVB Major Salivary Gland Cancer AJCC v7; Stage IVB Oral Cavity Adenoid Cystic Carcinoma AJCC v6 and v7; Stage IVC Major Salivary Gland Cancer AJCC v7; Stage IVC Oral Cavity Adenoid Cystic Carcinoma AJCC v6 and v7

  2. Endovascular Removal of Fractured Inferior Vena Cava Filter Fragments: 5-Year Registry Data with Prospective Outcomes on Retained Fragments.

    PubMed

    Kesselman, Andrew J; Hoang, Nam Sao; Sheu, Alexander Y; Kuo, William T

    2018-06-01

    To evaluate the safety and efficacy of attempted percutaneous filter fragment removal during retrieval of fractured inferior vena cava (IVC) filters and to report outcomes associated with retained filter fragments. Over a 5-year period, 82 consecutive patients presenting with a fractured IVC filter were prospectively enrolled into an institutional review board-approved registry. There were 27 men and 55 women (mean, 47 y; range, 19-85 y). After main filter removal, percutaneous removal of fragments was attempted if they were deemed intravascular and accessible on preprocedural computed tomography (CT), cone-beam CT, and/or intravascular ultrasound; distal pulmonary artery (PA) fragments were left alone. A total of 185 fragments were identified (81 IVC, 33 PA, 16 cardiac, 2 hepatic vein, 1 renal vein, 1 aorta, 51 retroperitoneal). Mean filter dwell time was 2,183 days (range, 59-9,936 d). Eighty-seven of 185 fragments (47%) were deemed amenable to attempted removal: 65 IVC, 11 PA, 8 cardiac, 2 hepatic, and 1 aortic. Primary safety outcomes were major procedure-related complications. Fragment removal was successful in 78 of 87 cases (89.7%; 95% confidence interval [CI], 81.3-95.2). There were 6 minor complications with no consequence (6.9%; 95% CI, 2.6-14.4) involving intraprocedural fragment embolization and 1 major complication (1.1%; 95% CI, 0.0-6.2), a cardiac tamponade that was successfully treated. The complication rate from attempted cardiac fragment removal was 12.5% (1 of 8; 95% CI, 0.3-52.7). Among patients with retained cardiopulmonary fragments (n = 19), 81% remained asymptomatic during long-term clinical follow-up of 845 days (range, 386-2,071 d). Percutaneous removal of filter fragments from the IVC and proximal PAs is safe and effective overall, but attempted intracardiac fragment removal carries a higher risk of complication. Most residual filter fragments not amenable to percutaneous removal remain asymptomatic and may be monitored clinically. Copyright © 2018 SIR. Published by Elsevier Inc. All rights reserved.

  3. Effect of a change in housing conditions on body weight, behavior and brain neurotransmitters in male C57BL/6J mice.

    PubMed

    Pasquarelli, Noemi; Voehringer, Patrizia; Henke, Julia; Ferger, Boris

    2017-08-30

    The development of modern housing regimes such as individually ventilated cage (IVC) systems has become very popular and attractive in order to reduce spreading of pathogenic organisms and to lower the risk to develop a laboratory animal allergy for staff members. Additionally, optimal housing of laboratory animals contributes to improve animal health status and ensures high and comparable experimental and animal welfare standards. However, it has not been clearly elucidated whether 1) a change to IVC systems have an impact on various physiological phenotypic parameters of mice when compared to conventional, standard cages and 2) if this is further affected by changing from social to single housing. Therefore, we investigated the influence of a change in housing conditions (standard cages with social housing changed to standard or IVC cages combined with social or single housing) on body weight, behavior and a neurochemical fingerprint of male C57BL/6J mice. Body weight progression was significantly reduced when changing mice to single or social IVC cages as well as in single standard cages when compared to social standard housing. Automated motor activity measurement in the open field showed that mice maintained in social husbandry with standard cages displayed the lowest exploratory behavior but the highest activity difference upon amphetamine treatment. Elevated plus maze test revealed that a change to IVC single and social housing as well as single standard housing produced anxiety-related behavior when compared to maintenance in social standard housing. Additionally, postmortem neurochemical analysis of the striatum using high-performance liquid chromatography coupled to electrochemical detection showed significant differences in striatal dopamine and serotonin turnover levels. In summary, our data indicate a crucial influence of a change in housing conditions on several mouse phenotype parameters. We propose that the maintenance of well-defined housing conditions is mandatory to ensure reproducible and comparable results and contributes to the application of the 3R refinement principle in animal studies by contributing to welfare and hygienical standards. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Prospective implementation of an algorithm for bedside intravascular ultrasound-guided filter placement in critically ill patients.

    PubMed

    Killingsworth, Christopher D; Taylor, Steven M; Patterson, Mark A; Weinberg, Jordan A; McGwin, Gerald; Melton, Sherry M; Reiff, Donald A; Kerby, Jeffrey D; Rue, Loring W; Jordan, William D; Passman, Marc A

    2010-05-01

    Although contrast venography is the standard imaging method for inferior vena cava (IVC) filter insertion, intravascular ultrasound (IVUS) imaging is a safe and effective option that allows for bedside filter placement and is especially advantageous for immobilized critically ill patients by limiting resource use, risk of transportation, and cost. This study reviewed the effectiveness of a prospectively implemented algorithm for IVUS-guided IVC filter placement in this high-risk population. Current evidence-based guidelines were used to create a clinical decision algorithm for IVUS-guided IVC filter placement in critically ill patients. After a defined lead-in phase to allow dissemination of techniques, the algorithm was prospectively implemented on January 1, 2008. Data were collected for 1 year using accepted reporting standards and a quality assurance review performed based on intent-to-treat at 6, 12, and 18 months. As defined in the prospectively implemented algorithm, 109 patients met criteria for IVUS-directed bedside IVC filter placement. Technical feasibility was 98.1%. Only 2 patients had inadequate IVUS visualization for bedside filter placement and required subsequent placement in the endovascular suite. Technical success, defined as proper deployment in an infrarenal position, was achieved in 104 of the remaining 107 patients (97.2%). The filter was permanent in 21 (19.6%) and retrievable in 86 (80.3%). The single-puncture technique was used in 101 (94.4%), with additional dual access required in 6 (5.6%). Periprocedural complications were rare but included malpositioning requiring retrieval and repositioning in three patients, filter tilt >/=15 degrees in two, and arteriovenous fistula in one. The 30-day mortality rate for the bedside group was 5.5%, with no filter-related deaths. Successful placement of IVC filters using IVUS-guided imaging at the bedside in critically ill patients can be established through an evidence-based prospectively implemented algorithm, thereby limiting the need for transport in this high-risk population. Copyright (c) 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  5. Peroperative electrocardiographic control of catheter tip position during implantation of femoral venous ports.

    PubMed

    Gibault, Pierre; Desruennes, Eric; Bourgain, Jean-Louis

    2015-01-01

    Electrocardiographic (ECG) guidance has been shown to be as effective than fluoroscopy to position the tip of central venous devices close to the superior vena cava (SVC)-right atrium (RA) junction. When SVC access is contraindicated, a femoral access may be used. The aim of this prospective study is to evaluate the effectiveness of ECG guidance to position the tip of femoral ports at inferior vena cava (IVC)-RA junction. Inclusion criterion was the need for femoral port implantation. After insertion of the dilator in the femoral vein, the catheter with the guide wire inside was introduced and the ECG signal collected at the tip of the guide (Celsite™ ECG, B. Braun, Germany) or via saline injected in the catheter (Nautilus™, Perouse, France). Fluoroscopy was performed at each change of the P-wave from IVC to RA. A final X-ray was performed after withdrawing the catheter 2 cm below the first P-wave change. A total of 18 patients were included between December 2011 and June 2013. The P-wave was most often negative in IVC, biphasic when the catheter entered RA and giant and positive at the top of RA. When the catheter was withdraw 2 cm below the first biphasic P-wave the tip was just below the IVC-RA junction in 17 patients. In one patient P-wave changes were not significant and the final position was adjusted under fluoroscopy. ECG guidance is effective to assess catheter tip position during femoral port placement and avoids the need for radiological methods.

  6. Outcome of Resection and Chemotherapy versus Chemotherapy Alone for Retroperitoneal Recurrence of Testicular Cancer Involving the Inferior Vena Cava: A Retrospective Cohort Study of 22 Consecutive Patients.

    PubMed

    Illuminati, Giulio; Calio, Francesco G; Angelici, Alberto M; Pizzardi, Giulia; Pasqua, Rocco; Masci, Federica; Vietri, Francesco

    2016-07-01

    Optimal treatment strategy for retroperitoneal recurrence of testicular cancer involving the inferior vena cava (IVC) is uncertain. The purpose of this study was to validate the hypothesis that surgical resection, en-bloc with the involved segment of IVC and its subsequent reconstruction followed by chemotherapy, would yield better oncologic results than chemotherapy alone. Two consecutive series of patients with retroperitoneal recurrence of testicular cancer involving the IVC, treated with surgical resection plus chemotherapy (group A, n=14) or chemotherapy alone (group B, n=8) were retrospectively reviewed. The mean duration of follow-up was was 65 months (range=8-184). Operative mortality and morbidity in group A, response to chemotherapy in group B, disease-specific survival and quality adjusted life-years (QALY) for both groups, were primary end-points of the study. Postoperative mortality and morbidity (group A) were, respectively, nil and 14%. In group B, two patients (25%) fully responded to chemotherapy and remained free from disease progression. Disease-specific survival at 3 and 5 years was 81% and 54% in group A and 36% in group B both at 3 and 5 years, respectively (p=0.02). QALY was 3.92 in group A and 0.77 for both 3 and 5 years in group B, respectively, (p=0.031). En bloc resection of retroperitoneal recurrence of testicular tumors invading the IVC, followed by chemotherapy, allows a better survival rate compared to chemotherapy alone. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  7. Strategies for prevention of iatrogenic inferior vena cava filter entrapment and dislodgement during central venous catheter placement.

    PubMed

    Wu, Alex; Helo, Naseem; Moon, Eunice; Tam, Matthew; Kapoor, Baljendra; Wang, Weiping

    2014-01-01

    Iatrogenic migration of inferior vena cava (IVC) filters is a potentially life-threatening complication that can arise during blind insertion of central venous catheters when the guide wire becomes entangled with the filter. In this study, we reviewed the occurrence of iatrogenic migration of IVC filters in the literature and assessed methods for preventing this complication. A literature search was conducted to identify reports of filter/wire entrapment and subsequent IVC filter migration. Clinical outcomes and complications were identified. A total of 38 cases of filter/wire entrapment were identified. All of these cases involved J-tip guide wires. Filters included 23 Greenfield filters, 14 VenaTech filters, and one TrapEase filter. In 18 cases of filter/wire entrapment, there was migration of the filter to the heart and other central venous structures. Retrieval of the migrated filter was successful in only four of the 18 cases, and all of these cases were complicated by strut fracture and distant embolization of fragments. One patient required resuscitation during retrieval. Successful disengagement was possible in 20 cases without filter migration. Iatrogenic migration of an IVC filter is an uncommon complication related to wire/filter entrapment. This complication can be prevented with knowledge of the patient's history, use of proper techniques when placing a central venous catheter, identification of wire entrapment at an early stage, and use of an appropriate technique to disengage an entrapped wire. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  8. Influence of 5 Different Caging Types and the Use of Cage-Changing Stations on Mouse Allergen Exposure

    PubMed Central

    Feistenauer, Susan; Sander, Ingrid; Schmidt, Jörg; Zahradnik, Eva; Raulf, Monika; Brielmeier, Markus

    2014-01-01

    Animal allergens constitute a serious health risk in laboratory animal facilities. To assess possibilities for allergen reduction by technical and organizational measures, we studied personnel exposure to mouse urinary aeroallergens in an animal facility with a holding capacity of 30,000 cages. Short-term (2 h) and intermediate-term (12 h) stationary samples (n = 107) and short-term (2 h) personnel samples (n = 119) were collected on polytetrafluorethylene filters by using air pumps. Long-term (14 d) stationary dust samples containing airborne allergens (n = 165) were collected with electrostatic dust fall collectors (EDC). Mouse allergens were quantified by ELISA. Personnel samples were collected during bedding disposal and refilling of clean cages as well as during cage changing with and without use of cage-changing station. Animal rooms were equipped with either open cages, cages with a soft filter top, cages with a rigid filter top (static microisolation caging), or with individually ventilated cages (IVC) with either a sealed or nonsealed lid, each in positive- or negative-pressure mode. Highest personnel allergen exposure was detected during cage change and emptying of soiled cages. Allergen concentrations were lowest in rooms with sealed IVC under positive or negative pressure, with unsealed IVC under negative pressure, and with static microisolation caging. The use of cage-changing stations and a vacuum bedding-disposal system reduced median personnel exposures 14- to 25-fold, respectively. Using sealed IVC and changing stations minimized allergen exposure, indicating that state-of-the-art equipment reduces exposure to mouse allergens and decreases health risks among animal facility personnel. PMID:25199090

  9. The Mid-Term Efficacy and Safety of a Permanent Nitinol IVC Filter (TrapEase)

    PubMed Central

    Liu, Wei Chiang; Choo, Sung Wook; Kim, Dong-Ik; Kim, Young Wook; Kim, Duk-Kyung; Shin, Sung Wook; Park, Kwang Bo; Jeon, Yong Hwan; Choo, In-Wook

    2005-01-01

    Objective 1) To evaluate the mid-term efficacy and safety of a permanent nitinol inferior vena cava (IVC) filter; 2) to evaluate filter effectiveness, filter stability and caval occlusion. Materials and Methods A prospective evaluation of the TrapEase IVC filter was performed on 42 patients (eight men, 34 women) ranging in age from 22 to 78 years (mean age 66 years). All patients were ill with a high risk of pulmonary embolism (PE). Indications for filter placement were: 1) deep vein thrombosis with recurrent thromboembolism; 2) and/or free-floating thrombus with contraindication to anticoagulation; and 3) complications in achieving adequate anticoagulation. Follow-up evaluations (mean: 15.4 months, range: 2 to 28 months) were performed at 6- and 12-month intervals after the procedure and included clinical histories, chart reviews, plain film, Doppler ultrasounds, and contrasted abdominal CT scans. Results In follow-up evaluations, the data analysis revealed no cases of symptomatic PE. There were no cases of filter migration, insertion site thrombosis, filter fracture, or vessel wall perforation. During the study, there was one case of filter thrombosis; early symptomatic thrombosis that was successfully treated in the hospital. Of the 42 subjects, eight died. These deaths were not related to the filter device or the implantation procedure, but to the underlying disease. Conclusion This study demonstrates that the TrapEase permanent IVC filter is a safe and an effective device with low complication rates and is best used in patients with thromboembolic disease with a high risk of PE. PMID:15968150

  10. Evaluating MRI based vascular wall motion as a biomarker of Fontan hemodynamic performance

    NASA Astrophysics Data System (ADS)

    Menon, Prahlad G.; Hong, Haifa

    2015-03-01

    The Fontan procedure for single-ventricle heart disease involves creation of pathways to divert venous blood from the superior & inferior venacavae (SVC, IVC) directly into the pulmonary arteries (PA), bypassing the right ventricle. For optimal surgical outcomes, venous flow energy loss in the resulting vascular construction must be minimized and ensuring close to equal flow distribution from the Fontan conduit connecting IVC to the left & right PA is paramount. This requires patient-specific hemodynamic evaluation using computational fluid dynamics (CFD) simulations which are often time and resource intensive, limiting applicability for real-time patient management in the clinic. In this study, we report preliminary efforts at identifying a new non-invasive imaging based surrogate for CFD simulated hemodynamics. We establish correlations between computed hemodynamic criteria from CFD modeling and cumulative wall displacement characteristics of the Fontan conduit quantified from cine cardiovascular MRI segmentations over time (i.e. 20 cardiac phases gated from the start of ventricular systole), in 5 unique Fontan surgical connections. To focus our attention on diameter variations while discounting side-to-side swaying motion of the Fontan conduit, the difference between its instantaneous regional expansion and inward contraction (averaged across the conduit) was computed and analyzed. Maximum Fontan conduit-average expansion over the cardiac cycle correlated with the anatomy-specific diametric offset between the axis of the IVC and SVC (r2=0.13, p=0.55) - a known factor correlated with Fontan energy loss and IVC-to-PA flow distribution. Investigation in a larger study cohort is needed to establish stronger statistical correlations.

  11. Distension of central great vein decreases sympathetic outflow in humans

    PubMed Central

    Cui, Jian; Gao, Zhaohui; Blaha, Cheryl; Herr, Michael D.; Mast, Jessica

    2013-01-01

    Classic canine studies suggest that central great vein distension evokes an autonomic reflex tachycardia (Bainbridge reflex). It is unclear whether central venous distension in humans is a necessary and sufficient stimulus to evoke a reflex increase in heart rate (HR), blood pressure (BP), and muscle sympathetic nerve activity (MSNA). Prior work from our laboratory suggests that limb venous distension evokes a reflex increase in BP and MSNA in humans. We hypothesized that in humans, compared with the limb venous distension, inferior vena cava (IVC) distension would evoke a less prominent increase in HR and MSNA. IVC distension (monitored with ultrasonography) was induced by two methods: 1) head-down tilt (HDT, N = 13); and 2) lower-body positive pressure (LBPP, N = 10). Two minutes of HDT induced IVC distension (Δ2.6 ± 0.2 mm, P < 0.001, ∼27% in cross-sectional area), slightly increased mean BP (Δ2.3 ± 0.7 mmHg, P = 0.005), decreased MSNA (Δ5.2 ± 0.8 bursts/min, P < 0.001, N = 10), and did not alter HR (P = 0.37). LBPP induced similar IVC distension, increased BP (Δ2.0 ± 0.7 mmHg, P < 0.01), and did not alter HR (P = 0.34). Thus central venous distension leads to a rapid increase in BP and a subsequent fall in MSNA. Central venous distension does not evoke either bradycardia or tachycardia in humans. The absence of a baroreflex-mediated bradycardia suggests that the Bainbridge reflex is engaged. Clearly, this reflex differs from the powerful sympathoexcitation peripheral venous distension reflex described in humans. PMID:23729210

  12. Distension of central great vein decreases sympathetic outflow in humans.

    PubMed

    Cui, Jian; Gao, Zhaohui; Blaha, Cheryl; Herr, Michael D; Mast, Jessica; Sinoway, Lawrence I

    2013-08-01

    Classic canine studies suggest that central great vein distension evokes an autonomic reflex tachycardia (Bainbridge reflex). It is unclear whether central venous distension in humans is a necessary and sufficient stimulus to evoke a reflex increase in heart rate (HR), blood pressure (BP), and muscle sympathetic nerve activity (MSNA). Prior work from our laboratory suggests that limb venous distension evokes a reflex increase in BP and MSNA in humans. We hypothesized that in humans, compared with the limb venous distension, inferior vena cava (IVC) distension would evoke a less prominent increase in HR and MSNA. IVC distension (monitored with ultrasonography) was induced by two methods: 1) head-down tilt (HDT, N = 13); and 2) lower-body positive pressure (LBPP, N = 10). Two minutes of HDT induced IVC distension (Δ2.6 ± 0.2 mm, P < 0.001, ~27% in cross-sectional area), slightly increased mean BP (Δ2.3 ± 0.7 mmHg, P = 0.005), decreased MSNA (Δ5.2 ± 0.8 bursts/min, P < 0.001, N = 10), and did not alter HR (P = 0.37). LBPP induced similar IVC distension, increased BP (Δ2.0 ± 0.7 mmHg, P < 0.01), and did not alter HR (P = 0.34). Thus central venous distension leads to a rapid increase in BP and a subsequent fall in MSNA. Central venous distension does not evoke either bradycardia or tachycardia in humans. The absence of a baroreflex-mediated bradycardia suggests that the Bainbridge reflex is engaged. Clearly, this reflex differs from the powerful sympathoexcitation peripheral venous distension reflex described in humans.

  13. Experimental investigation of the effects of inserting a bovine venous valve in the inferior vena cava of Fontan circulation

    NASA Astrophysics Data System (ADS)

    Santhanakrishnan, Arvind; Johnson, Jacob; Kotz, Monica; Tang, Elaine; Khiabani, Reza; Yoganathan, Ajit; Maher, Kevin

    2012-11-01

    The Fontan procedure is a palliative surgery performed on patients with single ventricle (SV) congenital heart defects. The SV is used for systemic circulation and the venous return from the inferior vena cava (IVC) and superior vena cava (SVC) is routed to the pulmonary arteries (PA), resulting in a total cavopulmonary connection (TCPC). Hepatic venous hypertension is commonly manifested in the Fontan circulation, leading to long-term complications including liver congestion and cirrhosis. Respiratory intrathoracic pressure changes affect the venous return from the IVC to the PA. Using a physical model of an idealized TCPC, we examine placement of a unidirectional bovine venous valve within the IVC as a method of alleviating hepatic venous hypertension. A piston pump is used to provide pulsatility in the internal flow through the TCPC, while intrathoracic pressure fluctuations are imposed on the external walls of the model using a pair of linear actuators. When implanted in the extrathoracic position, the hepatic venous pressure is lowered from baseline condition. The effects of changing caval flow distribution and intrathoracic pressure on TCPC hemodynamics will be examined.

  14. Control of respiration-driven retrograde flow in the subdiaphragmatic venous return of the Fontan circulation

    PubMed Central

    Vukicevic, M; Conover, T; Jaeggli, M; Zhou, J; Pennati, G; Hsia, TY; Figliola, RS

    2014-01-01

    Respiration influences the subdiaphragmatic venous return in the total cavopulmonary connection (TCPC) of the Fontan circulation whereby both the inferior vena cava (IVC) and hepatic vein flows can experience retrograde motion. Controlling retrograde flows could improve patient outcomes. Using a patient-specific model within a Fontan mock circulatory system with respiration, we inserted a valve into the IVC to examine its effects on local hemodynamics while varying retrograde volumes by changing vascular impedances. A bovine valved conduit reduced IVC retrograde flow to within 3% of antegrade flow in all cases. The valve closed only under conditions supporting retrograde flow and its effects on local hemodynamics increased with larger retrograde volume. Liver and TCPC pressures improved only while the valve leaflets were closed while cycle-averaged pressures improved only slightly (italic>1 mm Hg). Increased pulmonary vascular resistance raised mean circulation pressures but the valve functioned and cardiac output improved and stabilized. Power loss across the TCPC improved by 12–15% (pbold>0.05) with a valve. The effectiveness of valve therapy is dependent on patient vascular impedance. PMID:24814833

  15. Freeze-Dried Black Raspberries in Preventing Oral Cancer Recurrence in High-Risk Appalachian Patients Previously Treated With Surgery For Oral Cancer

    ClinicalTrials.gov

    2018-03-04

    Stage I Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage I Squamous Cell Carcinoma of the Oropharynx; Stage I Verrucous Carcinoma of the Oral Cavity; Stage II Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage II Squamous Cell Carcinoma of the Oropharynx; Stage II Verrucous Carcinoma of the Oral Cavity; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer

  16. Lab-on-a-chip in vitro compartmentalization technologies for protein studies.

    PubMed

    Zhu, Yonggang; Power, Barbara E

    2008-01-01

    In vitro compartmentalization (IVC) is a powerful tool for studying protein-protein reactions, due to its high capacity and the versatility of droplet technologies. IVC bridges the gap between chemistry and biology as it enables the incorporation of unnatural amino acids with modifications into biological systems, through protein transcription and translation reactions, in a cell-like microdrop environment. The quest for the ultimate chip for protein studies using IVC is the drive for the development of various microfluidic droplet technologies to enable these unusual biochemical reactions to occur. These techniques have been shown to generate precise microdrops with a controlled size. Various chemical and physical phenomena have been utilized for on-chip manipulation to allow the droplets to be generated, fused, and split. Coupled with detection techniques, droplets can be sorted and selected. These capabilities allow directed protein evolution to be carried out on a microchip. With further technological development of the detection module, factors such as addressable storage, transport and interfacing technologies, could be integrated and thus provide platforms for protein studies with high efficiency and accuracy that conventional laboratories cannot achieve.

  17. Type-IVC Secretion System: A Novel Subclass of Type IV Secretion System (T4SS) Common Existing in Gram-Positive Genus Streptococcus

    PubMed Central

    Chen, Chen; Gao, George F.

    2012-01-01

    A growing number of pathogens are being found to possess specialized secretion systems which they use in various ways to subvert host defenses. Type IV secretion system (T4SS) is one of versatile secretion systems essential for the virulence and even survival of some bacteria species, and they enable the secretion of protein and DNA substrates across the cell envelope. T4SS was once believed to be present only in Gram-negative bacteria. In this study, we present evidence of a new subclass of T4SS, Type-IVC secretion system and indicate its common existence in the Gram-positive bacterial genus Streptococcus. We further identified that VirB1, VirB4, VirB6 and VirD4 are the minimal key components of this system. Using genome comparisons and evolutionary relationship analysis, we proposed that Type-IVC secretion system is movable via transposon factors and mediates the conjugative transfer of DNA, enhances bacterial pathogenicity, and could cause large-scale outbreaks of infections in humans. PMID:23056296

  18. Safety and Effectiveness of the Denali Inferior Vena Cava Filter: Intermediate Follow-Up Results.

    PubMed

    Reis, Stephen P; Kovoor, Jerry; Sutphin, Patrick D; Toomay, Seth; Trimmer, Clayton; Pillai, Anil; Reddick, Mark; Kalva, Sanjeeva P

    2016-08-01

    The purpose of the study is to evaluate the clinical safety and effectiveness of the Denali (Bard, Tempe, Arizona) retrievable inferior vena cava (IVC) filter. In this retrospective study, authors reviewed the data of Denali IVC filters placed at their institution between 2013 and 2015. The clinical presentation, indications, and procedure-related complications during placement and retrieval were evaluated. The frequency of post filter pulmonary embolism (PE) and filter-related complications was assessed. Denali filters were placed in 87 patients (47 males; mean age: 56 years). Twenty patients presented with PE, 45 with deep vein thrombosis (DVT), and 21 with both PE and DVT, 1 filter was placed prophylactically before surgery. Indications for filter placement included contraindications to anticoagulation (AC; n = 80), failure of AC (n = 4), and complications of AC (n = 3). No patients had PE on follow-up imaging after filter placement. Retrieval was attempted in 31 patients after a mean period of 125 days (range: 34-324 days). The filter was successfully removed in 31 (100%) patients. Follow-up imaging, available in 71 (82%) patients (range: 2-538 days), demonstrated penetration of 15 legs in 5 patients, caval thrombus in 3, 1 resulting in caval occlusion, <15° filter tilt in 5, and no leg fractures or crossed legs. The Denali filter is safe during deployment and readily retrievable. The overall safety following deployment is similar to those reported in the literature, and the incidence of filter fractures and migration appears to be less than the previous generation of Bard devices. © The Author(s) 2016.

  19. The Need for Anticoagulation Following Inferior Vena Cava Filter Placement: Systematic Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ray, Charles E.; Prochazka, Allan

    Purpose. To perform a systemic review to determine the effect of anticoagulation on the rates of venous thromboembolism (pulmonary embolus, deep venous thrombosis, inferior vena cava (IVC) filter thrombosis) following placement of an IVC filter. Methods. A comprehensive computerized literature search was performed to identify relevant articles. Data were abstracted by two reviewers. Studies were included if it could be determined whether or not subjects received anticoagulation following filter placement, and if follow-up data were presented. A meta-analysis of patients from all included studies was performed. A total of 14 articles were included in the final analysis, but the datamore » from only nine articles could be used in the meta-analysis; five studies were excluded because they did not present raw data which could be analyzed in the meta-analysis. A total of 1,369 subjects were included in the final meta-analysis. Results. The summary odds ratio for the effect of anticoagulation on venous thromboembolism rates following filter deployment was 0.639 (95% CI 0.351 to 1.159, p = 0.141). There was significant heterogeneity in the results from different studies [Q statistic of 15.95 (p = 0.043)]. Following the meta-analysis, there was a trend toward decreased venous thromboembolism rates in patients with post-filter anticoagulation (12.3% vs. 15.8%), but the result failed to reach statistical significance. Conclusion. Inferior vena cava filters can be placed in patients who cannot receive concomitant anticoagulation without placing them at significantly higher risk of development of venous thromboembolism.« less

  20. Phase 1b Food Based Modulation of Biomarkers in Human Tissues at High-Risk for Oral Cancer.

    ClinicalTrials.gov

    2018-03-05

    Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Salivary Gland Squamous Cell Carcinoma; Stage 0 Hypopharyngeal Cancer; Stage 0 Laryngeal Cancer; Stage 0 Lip and Oral Cavity Cancer; Stage 0 Nasopharyngeal Cancer; Stage 0 Oropharyngeal Cancer; Stage 0 Paranasal Sinus and Nasal Cavity Cancer; Stage I Salivary Gland Cancer; Stage I Squamous Cell Carcinoma of the Hypopharynx; Stage I Squamous Cell Carcinoma of the Larynx; Stage I Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage I Squamous Cell Carcinoma of the Nasopharynx; Stage I Squamous Cell Carcinoma of the Oropharynx; Stage I Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage I Verrucous Carcinoma of the Larynx; Stage I Verrucous Carcinoma of the Oral Cavity; Stage II Salivary Gland Cancer; Stage II Squamous Cell Carcinoma of the Hypopharynx; Stage II Squamous Cell Carcinoma of the Larynx; Stage II Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage II Squamous Cell Carcinoma of the Nasopharynx; Stage II Squamous Cell Carcinoma of the Oropharynx; Stage II Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage II Verrucous Carcinoma of the Larynx; Stage II Verrucous Carcinoma of the Oral Cavity; Stage III Salivary Gland Cancer; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Oral Cavity Squamous Cell Carcinoma; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Nasal Cavity and Paranasal Sinus Cancer; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Oral Cavity Squamous Cell Carcinoma; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Oral Cavity Squamous Cell Carcinoma; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Paranasal Sinus and Nasal Cavity Squamous Cell Carcinoma; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer

  1. TACE Combined with Implantation of Irradiation Stent Versus TACE Combine with Bare Stent for HCC Complicated by IVCTT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Qing-hui; Zhang, Wen; Liu, Qing-xin

    PurposeThis study was designed to evaluate the safety and efficacy of transarterial chemoembolization (TACE) combined with intra-IVC implantation of an irradiation stent for the treatment of hepatocellular carcinoma (HCC) complicated by inferior vena cava tumor thrombosis (IVCTT).MethodsSixty-one consecutive patients with HCC complicated by IVCTT treated by TACE combined with IVC stenting were retrospectively analysed. IVC stenting was performed using a stent loaded with {sup 125}I seeds strands (the irradiation stent) in 33 patients (Group A) and 28 patients with a bare stent (Group B). Propensity score matching eliminated the baseline differences. Overall survival, oedema related to IVC obstruction remission ratemore » and procedure-related adverse events were compared between the two groups.ResultsThe adverse effect rate was similar for both Group A and Group B patients, and complications were adequately handled by medical treatment. TACE combined with implantation of an irradiation stent showed a significant median survival benefit over TACE combined with a bare stent, with a median survival time of 203.0 ± 28.135 days versus 93.0 ± 24.341 days (p = 0.006). The propensity score-matched (24 pairs) cohort analyses (200 ± 31.231 days vs. 66 ± 23.270 days, p = 0.019). The oedema remission rate was 97.0 % in group A patients and 96.4 % in group B, respectively. TACE-irradiation stent and object tumor response were the independent prognostic factors of favorable survival.ConclusionsTACE combined with irradiation stent implantation is a safe and effective treatment modality for patients with HCC complicated by IVCTT and may extend their survival time.« less

  2. The yeast telomerase recruitment module requires a specific RNA architecture.

    PubMed

    Laterreur, Nancy; Lemieux, Bruno; Neumann, Hannah; Berger-Dancause, Jean-Christophe; Lafontaine, Daniel; Wellinger, Raymund J

    2018-05-18

    Telomerases are ribonucleoprotein (RNP) enzymes that are related to reverse transcriptases. While they maintain genome stability, their composition varies significantly between species. Yeast telomerase RNPs contain an RNA that is comparatively large and its overall folding shows long helical segments with distal functional parts. Here we investigated the essential stem IVc module of the budding yeast telomerase RNA, called Tlc1. The distal part of stem IVc includes a conserved sequence element CS2a and structurally conserved features to which bind the Pop1/Pop6/Pop7 proteins and which together function analogously to the P3 domains of the RNase P/MRP RNPs. A more proximal bulged stem with the CS2 element is thought to associate with Est1. Previous data showed that changes in CS2a cause a loss of all of the proteins, not just the Pop-proteins, from stem IVc. The results here show that the association of Est1 with stem IVc indeed requires both the proximal bulged stem and the presence of the Tlc1 P3 domain with the associated Pop-proteins. Separating the P3-domain from the Est1 binding site by inserting only 2 base pairs into the helical stem between the two sites causes a complete loss of Est1 from the RNP and hence a telomerase-negative phenotype in vivo. Still, the distal P3 domain with the associated Pop-proteins remains intact. Moreover, the P3 domain also ensures Est2 stability on the RNP independently of the Est1 association. Therefore, the recruitment module of the Tlc1 RNA requires a very tight architectural organization for telomerase function in vivo. Published by Cold Spring Harbor Laboratory Press for the RNA Society.

  3. Imaging Analysis of Hepatoblastoma Resectability Across Neoadjuvant Chemotherapy

    PubMed Central

    Murphy, Andrew J.; Ayers, Gregory D.; Hilmes, Melissa A.; Mukherjee, Kaushik; Wilson, Kevin J.; Allen, Wade M.; Fernandez-Pineda, Israel; Shinall, Myrick C.; Zhao, Zhiguo; Furman, Wayne L.; McCarville, Mary Beth; Davidoff, Andrew M.; Lovvorn, Harold N.

    2013-01-01

    Purpose Hepatoblastomas often require neoadjuvant chemotherapy to facilitate partial hepatectomy, which necessitates freedom of tumor borders from the confluence of hepatic veins (COHV), portal vein bifurcation (PVB), and retrohepatic inferior vena cava (IVC). This study aimed to clarify the effect of incremental neoadjuvant cycles on the AHEP0731 protocol criteria of hepatoblastoma resectability. Methods Hepatoblastoma responses to neoadjuvant chemotherapy were analyzed among patients (n=23) treated at two children’s hospitals between 1996 and 2010. Using digital imaging data, ellipsoid and point-based models were created to measure tumor volume regression and respective distances from tumor borders nearest to the COHV, PVB, and IVC. Results Hepatoblastoma volumes regressed with incremental neoadjuvant chemotherapy cycles (p<0.001). Although tumor borders regressed away from the COHV (p=0.008), on average only 1.1mm was gained. No change from tumor borders to the PVB was detected (p=0.102). Distances from tumor borders to the IVC remained stable at one hospital (p=0.612), but increased only 0.15mm every 10 days of therapy at the other (p=0.002). Neoadjuvant chemotherapy induced slightly more tumors to meet the threshold vascular margin of 1cm (baseline to completion): COHV, 11 (47.8%) to 17 (73.9%; p=0.058); PVB, 11 (47.8%) to 15 (65.2%; p=0.157); IVC, 4 (17.4%) to 10 (43.5%; p=0.034). No differences were detected in demographic or disease-specific characteristics between patients who did or did not achieve this 1cm margin after conclusion of chemotherapy. Conclusion Hepatoblastoma volumes regress significantly with increasing neoadjuvant chemotherapy cycles. However, tumors often remain anchored to the major hepatic vasculature, showing marginal improvement in resectability criteria. PMID:23845613

  4. Murine norovirus detection in the exhaust air of IVCs is more sensitive than serological analysis of soiled bedding sentinels.

    PubMed

    Zorn, Julia; Ritter, Bärbel; Miller, Manuel; Kraus, Monika; Northrup, Emily; Brielmeier, Markus

    2017-06-01

    One limitation to housing rodents in individually ventilated cages (IVCs) is the ineffectiveness of traditional health monitoring programs that test soiled bedding sentinels every quarter. Aerogen transmission does not occur with this method. Moreover, the transmission of numerous pathogens in bedding is uncertain, and sentinel susceptibility to various pathogens varies. A novel method using particle collection from samples of exhaust air was developed in this study which was also systematically compared with routine health monitoring using soiled bedding sentinels. We used our method to screen these samples for the presence of murine norovirus (MNV), a mouse pathogen highly prevalent in laboratory animal facilities. Exhaust air particles from prefilters of IVC racks with known MNV prevalence were tested by quantitative reverse transcription polymerase chain reaction (RT-qPCR). MNV was detected in exhaust air as early as one week with one MNV-positive cage per rack, while sentinels discharged MNV RNA without seroconverting. MNV was reliably and repeatedly detected in particles collected from samples of exhaust air in all seven of the three-month sampling rounds, with increasing MNV prevalence, while sentinels only seroconverted in one round. Under field conditions, routine soiled bedding sentinel health monitoring in our animal facility failed to identify 67% ( n = 85) of positive samples by RT-qPCR of exhaust air particles. Thus, this method proved to be highly sensitive and superior to soiled bedding sentinels in the reliable detection of MNV. These results represent a major breakthrough in hygiene monitoring of rodent IVC systems and contribute to the 3R principles by reducing the number of animals used and by improving experimental conditions.

  5. Thrombogenesis with continuous blood flow in the inferior vena cava. A novel mouse model.

    PubMed

    Diaz, José A; Hawley, Angela E; Alvarado, Christine M; Berguer, Alexandra M; Baker, Nichole K; Wrobleski, Shirley K; Wakefield, Thomas W; Lucchesi, Benedict R; Myers, Daniel D

    2010-08-01

    Several rodent models have been used to study deep venous thrombosis (DVT). However, a model that generates consistent venous thrombi in the presence of continuous blood flow, to evaluate therapeutic agents for DVT, is not available. Mice used in the present study were wild-type C57BL/6 (WT), plasminogen activator inhibitor-1 (PAI-1) knock out (KO) and Delta Cytoplasmic Tail (DCT). An electrolytic inferior vena cava (IVC) model (EIM) was used. A 25G stainless-steel needle, attached to a silver coated copper wire electrode (anode), was inserted into the exposed caudal IVC. Another electrode (cathode) was placed subcutaneously. A current of 250 muAmps over 15 minutes was applied. Ultrasound imaging was used to demonstrate the presence of IVC blood flow. Analyses included measurement of plasma soluble P-selectin (sP-Sel), thrombus weight (TW), vein wall morphometrics, P-selectin and Von Willebrand factor (vWF) staining, transmission electron microscopy (TEM), scanning electron microscopy (SEM); and the effect of enoxaparin on TW was evaluated. A current of 250 muAmps over 15 minutes consistently promoted thrombus formation in the IVC. Plasma sP-Sel was decreased in PAI-1 KO and increased in DCT vs. WT (WT/PAI-1: p=0.003, WT/DCT: p=0.0002). Endothelial activation was demonstrated by SEM, TEM, P-selectin and vWF immunohistochemistry and confirmed by inflammatory cell counts. Ultrasound imaging demonstrated thrombus formation in the presence of blood flow. Enoxaparin significantly reduced the thrombus size by 61% in this model. This EIM closely mimics clinical venous disease and can be used to study endothelial cell activation, leukocyte migration, thrombogenesis and therapeutic applications in the presence of blood flow.

  6. Evaluation of blood flow distribution asymmetry and vascular geometry in patients with Fontan circulation using 4-D flow MRI

    PubMed Central

    Jarvis, Kelly; Schnell, Susanne; Barker, Alex J.; Garcia, Julio; Lorenz, Ramona; Rose, Michael; Chowdhary, Varun; Carr, James; Robinson, Joshua D.; Rigsby, Cynthia K.; Markl, Michael

    2016-01-01

    Background Asymmetrical caval to pulmonary blood flow is suspected to cause complications in patients with Fontan circulation. The aim of this study was to test the feasibility of 4-D flow MRI for characterizing the relationship between 3-D blood flow distribution and vascular geometry. Objective We hypothesized that both flow distribution and geometry can be calculated with low interobserver variability and will detect a direct relationship between flow distribution and Fontan geometry. Materials and methods Four-dimensional flow MRI was acquired in 10 Fontan patients (age: 16±4 years [mean ± standard deviation; range 9–21 years]). The Fontan connection was isolated by 3-D segmentation to evaluate flow distribution from the inferior vena cava (IVC) and superior vena cava (SVC) to the left and right pulmonary arteries (LPA, RPA) and to characterize geometry (cross-sectional area, caval offset, vessel angle). Results Flow distribution results indicated SVC flow tended toward the RPA while IVC flow was more evenly distributed (SVC to RPA: 78%±28 [9–100], IVC to LPA: 54%±28 [4–98]). There was a significant relationship between pulmonary artery cross-sectional area and flow distribution (IVC to RPA: R2=0.50, P=0.02; SVC to LPA: R2=0.81, P=0.0004). Good agreement was found between observers and for flow distribution when compared to net flow values. Conclusion Four-dimensional (4-D) flow MRI was able to detect relationships between flow distribution and vessel geometry. Future studies are warranted to investigate the potential of patient specific hemodynamic analysis to improve diagnostic capability. PMID:27350377

  7. Toxic effects of ethylene oxide residues on bovine embryos in vitro.

    PubMed

    Holyoak, G R; Wang, S; Liu, Y; Bunch, T D

    1996-04-15

    The potential of ethylene oxide (EtO) residues in exposed plastic tissue culture dishes to adversely affect bovine oocyte maturation, fertilization and subsequent embryonic development was monitored. In experiment 1, the effects of aeration time and aeration combined with washing of EtO-gassed culture dishes on the extent of residual toxicity were investigated. There was no cleavage in any treatment in which oocytes were matured and fertilized in dishes exposed to EtO. EtO residues caused functional degeneration of oocytes even when culture dishes were aerated for more than 12 days post EtO-exposure and repeatedly washed. In experiment 2, the residual toxicity of EtO gas on in vitro maturation (IVM), in vitro fertilization (IVF) and in vitro culture (IVC) were evaluated. Cleavage rate significantly decreased and post-cleavage development was retarded in ova maintained in dishes treated with EtO either during IVM or IVF. EtO residues may be more detrimental to spermatozoa than to oocytes which may have been the primary cause of fertilization failure during IVF.

  8. KILT (Kidney and IVC Abnormalities with Leg Thrombosis) Syndrome in a 41-Years-Old Man with Loin Pain and Fever.

    PubMed

    Fung, James Kiujing; Yeung, Victor Hip Wo; Chu, Sau Kwan; Man, Chi Wan

    2017-05-01

    KILT syndrome is a rare condition composing the triad of kidney and inferior vena cava anomaly and extensive venous thrombosis. We present a case of newly diagnosed KILT syndrome in a 41-years-old gentleman presenting with loin pain and fever. Reviewing previous case reports, KILT syndrome is usually an incidental finding on imaging studies and there is a wide scope of initial clinical presentations. However, recent evidence suggests IVC anomaly may have caused subsequent renal hypoplasia. Identification of the underlying etiology may be helpful in planning early vascular intervention to treat the condition.

  9. Severe cyanosis after Kawashima operation resulting from congenital portosystemic shunt.

    PubMed

    Nakamura, Yuki; Aoki, Mitsuru; Hagino, Ikuo; Nakajima, Hiromichi

    2012-04-01

    We describe an unusual case of a patient with polysplenia, inferior vena cava (IVC) interruption, and unrecognized congenital portosystemic venous connection (CPVC) in whom severe cyanosis developed in the acute postoperative stage after a Kawashima operation and required urgent surgical division of the CPVC. It has been stressed recently that CPVCs and other abdominal venous abnormalities have been underdiagnosed in patients with polysplenia and IVC interruption, and we think that a routine evaluation of abdominal venous connections should be mandatory before considering the Kawashima operation for these patients. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Vorinostat in Treating Patients With Locally Advanced, Recurrent, or Metastatic Adenoid Cystic Carcinoma

    ClinicalTrials.gov

    2018-05-23

    Recurrent Oral Cavity Adenoid Cystic Carcinoma; Recurrent Salivary Gland Carcinoma; Salivary Gland Adenoid Cystic Carcinoma; Stage III Major Salivary Gland Cancer AJCC v7; Stage III Oral Cavity Adenoid Cystic Carcinoma AJCC v6 and v7; Stage IVA Major Salivary Gland Cancer AJCC v7; Stage IVA Oral Cavity Adenoid Cystic Carcinoma AJCC v6 and v7; Stage IVB Major Salivary Gland Cancer AJCC v7; Stage IVB Oral Cavity Adenoid Cystic Carcinoma AJCC v6 and v7; Stage IVC Major Salivary Gland Cancer AJCC v7; Stage IVC Oral Cavity Adenoid Cystic Carcinoma AJCC v6 and v7; Tongue Carcinoma

  11. Guenter Tulip Filter Retrieval Experience: Predictors of Successful Retrieval

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turba, Ulku Cenk, E-mail: uct5d@virginia.edu; Arslan, Bulent, E-mail: ba6e@virginia.edu; Meuse, Michael, E-mail: mm5tz@virginia.edu

    We report our experience with Guenter Tulip filter placement indications, retrievals, and procedural problems, with emphasis on alternative retrieval techniques. We have identified 92 consecutive patients in whom a Guenter Tulip filter was placed and filter removal attempted. We recorded patient demographic information, filter placement and retrieval indications, procedures, standard and nonstandard filter retrieval techniques, complications, and clinical outcomes. The mean time to retrieval for those who experienced filter strut penetration was statistically significant [F(1,90) = 8.55, p = 0.004]. Filter strut(s) IVC penetration and successful retrieval were found to be statistically significant (p = 0.043). The filter hook-IVC relationshipmore » correlated with successful retrieval. A modified guidewire loop technique was applied in 8 of 10 cases where the hook appeared to penetrate the IVC wall and could not be engaged with a loop snare catheter, providing additional technical success in 6 of 8 (75%). Therefore, the total filter retrieval success increased from 88 to 95%. In conclusion, the Guenter Tulip filter has high successful retrieval rates with low rates of complication. Additional maneuvers such as a guidewire loop method can be used to improve retrieval success rates when the filter hook is endothelialized.« less

  12. Experiment on Synchronous Timing Signal Detection from ISDB-T Terrestrial Digital TV Signal with Application to Autonomous Distributed ITS-IVC Network

    NASA Astrophysics Data System (ADS)

    Karasawa, Yoshio; Kumagai, Taichi; Takemoto, Atsushi; Fujii, Takeo; Ito, Kenji; Suzuki, Noriyoshi

    A novel timing synchronizing scheme is proposed for use in inter-vehicle communication (IVC) with an autonomous distributed intelligent transport system (ITS). The scheme determines the timing of packet signal transmission in the IVC network and employs the guard interval (GI) timing in the orthogonal frequency divisional multiplexing (OFDM) signal currently used for terrestrial broadcasts in the Japanese digital television system (ISDB-T). This signal is used because it is expected that the automotive market will demand the capability for cars to receive terrestrial digital TV broadcasts in the near future. The use of broadcasts by automobiles presupposes that the on-board receivers are capable of accurately detecting the GI timing data in an extremely low carrier-to-noise ratio (CNR) condition regardless of a severe multipath environment which will introduce broad scatter in signal arrival times. Therefore, we analyzed actual broadcast signals received in a moving vehicle in a field experiment and showed that the GI timing signal is detected with the desired accuracy even in the case of extremely low-CNR environments. Some considerations were also given about how to use these findings.

  13. Photodynamic Therapy With HPPH in Treating Patients With Squamous Cell Carcinoma of the Oral Cavity

    ClinicalTrials.gov

    2016-04-19

    Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Stage I Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage I Squamous Cell Carcinoma of the Oropharynx; Stage I Verrucous Carcinoma of the Oral Cavity; Stage II Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage II Squamous Cell Carcinoma of the Oropharynx; Stage II Verrucous Carcinoma of the Oral Cavity; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Verrucous Carcinoma of the Oral Cavity

  14. Ovine secondary follicles vitrified out the ovarian tissue grow and develop in vitro better than those vitrified into the ovarian fragments.

    PubMed

    Lunardi, Franciele Osmarini; de Aguiar, Francisco Leo Nascimento; Duarte, Ana Beatriz Graça; Araújo, Valdevane Rocha; de Lima, Laritza Ferreira; Ribeiro de Sá, Naiza Arcângela; Vieira Correia, Hudson Henrique; Domingues, Sheyla Farhayldes Souza; Campello, Cláudio Cabral; Smitz, Johan; de Figueiredo, José Ricardo; Ribeiro Rodrigues, Ana Paula

    2016-04-15

    Cryopreservation of preantral follicles is a promising technique to preserve female fertility. The aim of this study was to evaluate the effect of vitrification on the development of secondary follicles included in ovarian tissue or isolated after microdissection. An important end point included is the capacity of grown oocytes to resume meiosis. Sheep ovarian cortexes were cut into fragments and split into three different groups: (1) fresh (control): secondary follicles isolated without any previous vitrification; (2) follicle-vitrification (follicle-vit): secondary follicles vitrified in isolated form; and (3) tissue-vitrification (tissue-vit): secondary follicles vitrified within fragments of ovarian tissue (in situ former) and subsequently subjected to isolation. From the three groups, isolated secondary follicles were submitted to IVC for 18 days. After IVC, cumulus-oocyte complexes (COCs) were harvested from follicles. As an additional control group, in vivo grown, in vivo-grown COCs were collected from antral ovarian follicles. All, recovered COCs were matured and the chromatin configuration was evaluated. Data were analyzed by ANOVA, and the means were compared by Student-Newman-Keuls test, and by chi-square. Differences were considered to be significant when P < 0.05. Isolated preantral follicles from all treatments had normal morphology, antrum formation, and low follicle degeneration after IVC. The growth rate between control and follicle-vit did not differ (P > 0.05), and was higher (P < 0.05) than for tissue-vit. The percentage of follicles that decreased diameter during IVC was significantly higher in tissue-vit than the in follicle-vit. Recovery rate of oocytes from normal follicles was higher in follicle-vit than in tissue-vit. Furthermore, oocyte viability was lower in tissue-vit than other treatments, and follicle-vit did not differ from control and in vivo grown. The percentage of oocytes meiosis resuming was not different between treatments except for in vivo grown. After vitrification, only follicle-vit showed metaphase I oocyte. We conclude that secondary follicles vitrified after isolation displayed a better follicular growth rate, oocyte viability, percentage of oocytes reaching the metaphase I stage, and fewer follicles with decreased diameter after IVC. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Culture of domestic cat ovarian tissue in vitro and in the chick embryo chorioallantoic membrane.

    PubMed

    Vilela, J M V; Leonel, E C R; D'Oliveira, L; Paiva, R E G; Miranda-Vilela, A L; Amorim, C A; Pic-Taylor, A; Lucci, C M

    2016-10-15

    In vitro culture and transplantation procedures are essential protocols employed in the evaluation of ovarian follicle survival and development. Culture in the chorioallantoic membrane (CAM) of chick embryos is an intermediate method that provides important follicle development information and has not been tested for cat ovaries to date. The aim of this study was to investigate if in vitro and CAM culture could be used as short-term systems to study cat ovarian tissue development. The ovaries of eight cats were dissected into 3-mm(3) cubes, cultured in vitro and in CAM for up to 5 days, and stained with hematoxylin-eosin and Gomori trichrome. Cell proliferation was analyzed using anti-Ki67. Possible differences among groups were investigated by analysis of variance or the Kruskal-Wallis test followed by Bonferroni correction. The T-test or Wilcoxon test was used to verify differences between the CAM and IVC. Results revealed that 87.5% of all follicles were primordial during culture. The percentage of primordial follicles in the morphologically normal follicles (MNF) pool was always higher than 80%, with the exception of Day 3 of CAM culture, but the number of MNF reduced significantly from Day 0 (600 out of 777 follicles) to Day 5 in the CAM (91 out of 171) and IVC (296 out of 686). The number of primordial follicles in 1 mm(3) in Days 2, 3, and 5 in the CAM was significantly lower than that in the control (Day 0). No cellular proliferation was observed in culture. Vascularization occurred in the CAM culture, but with no association to follicular viability. In addition, both methods showed an increase in connective tissue during culture. Although no significant differences were observed in the percentage of MNF, there was a reduction in the total number of follicles, both for IVC and CAM-cultured ovarian tissue. Furthermore, anti-Ki67 did not stain any follicle after Day 0 in IVC or in CAM culture. Neither system was capable of promoting follicle growth and/or development. The results show that the CAM is not a suitable system for feline ovarian tissue and highlight the necessity to improve IVC systems in cats. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Retrievable Inferior Vena Cava Filters: Indications, Indwelling Time, Removal, Success and Complication Rates.

    PubMed

    Tashbayev, Alisher; Belenky, Alexander; Litvin, Sergey; Knizhnik, Michael; Bachar, Gil N; Atar, Eli

    2016-02-01

    Various vena cava filters (VCF) are designed with the ability to be retrieved percutaneously. Yet, despite this option most of them remain in the inferior vena cava (IVC). To report our experience in the placement and retrieval of three different types of VCFs, and to compare the indications for their insertion and retrieval as reported in the literature. During a 5 year period three types of retrievable VCF (ALN, OptEase, and Celect) were inserted in 306 patients at the Rabin Medical Center (Beilinson and Hasharon hospitals). Indications, retrieval rates, median time to retrieval, success and complication rates were viewed and assessed in the three groups of filter types and were compared with the data of similar studies in the literature. Of the 306 VCFs inserted, 31 (10.1%) were retrieved with equal distribution in the three groups. In most patients the reason for filter insertion was venous thromboembolic events (VTE) and contraindications to anticoagulant therapy. Mean age was 68.38 ± 17.5 years (range 18-99) and was noted to be significantly higher compared to similar studies (53-56 years) (P < 0.0001). Multi-trauma patients were significantly older (71.11 ± 14.99 years) than post-pulmonary embolism patients (48.03 ± 20.98 years, P < 0.0001) and patients with preventive indication (26.00 ± 11.31, P < 0.0001). The mean indwelling time was 100.6 ± 103.399 days. Our results are comparable with the results of other studies, and there was no difference in percentage of retrieval or complications between patients in each of the three groups. In 1 of 10 patients filters should be removed after an average of 3.5 months. All three IVC filter types used are safe to insert and retrieve.

  17. Adult Wilms tumor: Case report.

    PubMed

    Morabito, V; Guglielmo, N; Melandro, F; Mazzesi, G; Alesini, F; Bosco, S; Berloco, P B

    2015-01-01

    Wilms tumor (WT) occurs infrequently in adults. Even rarer is adult WT with extension by direct intravascular spread into the right side of the heart. The present report describes a WT with intracaval and intracardiac extension in a 38-year-young man. In addition, thrombus extension above the infrahepatic IVC represents a major technical topic for surgeons because of the possible occurrence of uncontrollable hemorrhages and tumor fragmentation. We report the results of a surgical approach to caval thrombosis including the isolation of the IVC from the liver as routinely performed during liver harvesting. The morphologic and immune-histochemical findings confirmed the diagnosis. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Early ultrasonographic evaluation of tumor thrombus level during sunitinib therapy for renal cell carcinoma.

    PubMed

    Sano, Futoshi; Fusayasu, Syusei; Otake, Shinji; Yamanaka, Hiroyuki; Tatenuma, Tomoyuki; Sakata, Ryoko; Makiyama, Kazuhide; Nakaigawa, Noboru; Yao, Masahiro; Kubota, Yoshinobu

    2013-10-01

    A 72-year-old man presenting with a 14-cm left renal mass, an inferior vena cava (IVC) tumor thrombus, and pulmonary metastases underwent renal mass biopsy that revealed clear cell renal cell carcinoma. Because of metastases and the extent of the tumor thrombus, sunitinib was administered, which resulted in a marked reduction in the tumor thrombus (from level III to level II after 11 weeks of treatment). Ultrasonography, preceding computed tomography, showed a slight shrinkage of the tumor thrombus level in the first 2 weeks. Therefore, ultrasound may be advantageous to monitor the IVC tumor thrombus level during the early phase of targeted therapy.

  19. Combined Resection of the Liver and Inferior Vena Cava for Hepatic Malignancy

    PubMed Central

    Hemming, Alan W.; Reed, Alan I.; Langham, Max R.; Fujita, Shiro; Howard, Richard J.

    2004-01-01

    Objective: The objective of this paper is to review the results of combined resection of the liver and inferior vena cava for hepatic malignancy. The morbidity and mortality along with preliminary survival data are assessed in order to determine the utility of this aggressive approach to otherwise unresectable tumors. Summary Background Data: Involvement of the inferior vena cava has traditionally been considered a contraindication to resection for advanced tumors of the liver because the surgical risks are high and the long-term prognosis is poor. Progress in liver surgery allows resection in some cases. Methods: Twenty-two patients undergoing hepatic resection from 1997 to 2003, that also required resection and reconstruction of the inferior vena cava (IVC), were reviewed. The median age was 49 years (range 2 to 68 years). Resections were carried out for: hepatocellular carcinoma (n = 6), colorectal metastases (n = 6), cholangiocarcinoma (n = 5), gastrointestinal stromal tumor (n = 2), hepatoblastoma (n = 2), and squamous cell carcinoma in 1 patient. Liver resections performed included 13 right trisegmentectomies, 6 right lobectomies extended to include the caudate lobe, and 3 left trisegmentectomies. Complex ex vivo procedures were performed in 2 cases using venovenous bypass while the other 20 cases were performed using varying degrees of vascular isolation. In situ cold perfusion of the liver was used in 1 case. The IVC was reconstructed with ringed Gore-Tex tube graft (n = 14), primarily (n = 6), or with Gore-Tex patches (n = 2). Results: There were 2 perioperative deaths (9%). One cirrhotic patient died of liver failure 3 weeks post operatively and 1 patient with cholangiocarcinoma died of pulmonary hemorrhage secondary to a cavitating pulmonary infection after aspiration pneumonia 6 weeks after resection. Six patients had evidence of postoperative liver failure that resolved with supportive management and 2 patients required temporary dialysis. All vascular reconstructions were patent at last follow-up. With median follow-up of 26 months, 5 patients have died of recurrent malignancy at 44, 40, 32, 26, and 24 months, while an additional patient is alive with disease at 31 months. Actuarial 1-, 3-, and 5-year survivals were 85%, 60%, and 33%, respectively. Conclusions: IVC involvement by hepatic malignancy does not necessarily preclude resection. Liver resection with reconstruction of the inferior vena cava can be performed in selected cases. The increased risk associated with the procedure appears to be balanced by the possible benefits, particularly when the lack of alternative curative approaches is considered. PMID:15082976

  20. Robotic-Assisted Inferior Vena Cava Filter Retrieval.

    PubMed

    Owji, Shahin; Lu, Tony; Loh, Thomas M; Schwein, Adeline; Lumsden, Alan B; Bismuth, Jean

    2017-01-01

    Although anticoagulation remains the mainstay of therapy for patients with venous thromboembolism, guidelines recommend the use of inferior vena cava (IVC) filters in those who fail anticoagulation or have contraindications to its use. Short-term use of filters has proven effective in reducing the rate of pulmonary embolism. However, their extended use is associated with a variety of complications such as thrombosis, filter migration, or caval perforation, thus making a case for timely filter retrieval. This is the case of a 68-year-old female with a history of chronic oral anticoagulation use for multiple deep venous thrombi (DVT) and pulmonary emboli (PE) who required cervical and thoracic spinal intervention for spondylosis and foramina stenosis. Given her increased risk of recurrent DVT and PE perioperatively, we elected to place a Cook Celect ™ IVC filter (Cook Medical, Bloomington, IN) after oral anticoagulation was stopped for the procedure. Her treatment course was prolonged due to wound-healing complications. We elected to use the Magellan Robotic Catheter System (Hansen Medical, Mountain View, CA) for filter retrieval when she presented 6 months later with caval perforation from the filter struts. With its ease of use, superior mechanical stability, and maneuverability, robot-assisted IVC filter retrieval may be a safer and more reliable substitute for traditional navigation techniques when presented with challenging filter retrievals.

  1. Observation of dark pulses in 10 nm thick YBCO nanostrips presenting hysteretic current voltage characteristics

    NASA Astrophysics Data System (ADS)

    Ejrnaes, M.; Parlato, L.; Arpaia, R.; Bauch, T.; Lombardi, F.; Cristiano, R.; Tafuri, F.; Pepe, G. P.

    2017-12-01

    We have fabricated several 10 nm thick and 65 nm wide YBa2Cu3O7-δ (YBCO) nanostrips. The nanostrips with the highest critical current densities are characterized by hysteretic current voltage characteristics (IVCs) with a direct bistable switch from the zero-voltage to the finite voltage state. The presence of hysteretic IVCs allowed the observation of dark pulses due to fluctuations phenomena. The key role of the bistable behavior is its ability to transform a small disturbance (e.g. an intrinsic fluctuation) into a measurable transient signal, i.e. a dark pulse. On the contrary, in devices characterized by lower critical current density values, the IVCs are non-hysteretic and dark pulses have not been observed. To investigate the physical origin of the dark pulses, we have measured the bias current dependence of the dark pulse rate: the observed exponential increase with the bias current is compatible with mechanisms based on thermal activation of magnetic vortices in the nanostrip. We believe that the successful amplification of small fluctuation events into measurable signals in nanostrips of ultrathin YBCO is a milestone for further investigation of YBCO nanostrips for superconducting nanostrip single photon detectors and other quantum detectors for operation at higher temperatures.

  2. One-stage surgery for removal of intravascular leiomyomatosis extending to right ventricle.

    PubMed

    Chiang, Ching-Shu; Chen, Po-Lin; Kuo, Tzu-Ting; Chen, I-Ming; Wu, Nai-Yuan; Chang, Hsiao-Huang

    2018-03-01

    Intravascular leiomyomatosis (IVL) is a rare nonmalignant tumor that can be fatal if untreated. A 49-year-old nulliparous Asian woman who underwent hysterectomy and left salpingo-oophorectomy for multiple uterine leiomyomas 18 months prior presented complaining of intermittent palpitation and chest tightness for approximately 1 month. Echocardiography revealed a large mobile tumor mass extending from the inferior vena cava (IVC) to the right atrium that partially obstructed IVC flow and tricuspid inflow. Thoracicabdominopelvic computed tomography revealed a left adnexal tumor (4.8 × 2.5 cm) causing intravascular obstruction extending from the left internal iliac vein to the IVC, right atrium, and right ventricle. IVL with right heart involvement INTERVENTIONS:: Under cardiopulmonary bypass, a one-stage surgery combining sternotomy and laparotomy was performed. The tumor was approached and extracted via sternotomy, and tumor detachment and removal of residual tumors was accomplished via laparotomy. A firm, smooth, and regularly shape tumor 15.5 × 5.5 × 2.5 in size was completely removed and histopathologically confirmed as IVL. The patient tolerated the surgical procedure well and no postoperative complication was noted. We describe a one-stage surgical approach to completely remove an IVL extending to the right ventricle.

  3. Complex left profunda femoris vein to renal vein bypass for the management of progressive chronic iliofemoral occlusion.

    PubMed

    Anaya-Ayala, Javier E; Adams, Matthew K; Telich-Tarriba, Jose E; Dresser, Kelly L; Ismail, Nyla; Peden, Eric K

    2013-01-01

    Chronic occlusions of the inferior vena cava (IVC) and iliofemoral veins are long-term sequelae of deep venous thrombosis (DVT) that can lead to postthrombotic syndrome (PTS). Patients may present with a wide spectrum of signs and symptoms, ranging from mild discomfort and swelling to severe venous hypertension and ulcerations. We report a 68-year-old man who had a history of left lower extremity DVT after a laminectomy and who developed PTS with nonhealing ulcers. The patient underwent a cross-pubic femorofemoral venous bypass that failed to improve his clinical status. After unsuccessful endovascular attempts for recanalization of the iliofemoral segment, a profunda femoris to IVC bypass was performed. The symptoms recurred 2 years later. Venography revealed restenosis at the caval anastomosis that did not resolve by endovascular means. A surgical revision was performed, and given the quality of the IVC, a jump bypass was created to the left renal vein. The swelling improved and the ulcers healed completely. Twenty-eight months after the complex reconstructions, he remains ulcer-free with mild edema controlled with stockings. Venous reconstructions remain a viable option for patients with symptomatic and recalcitrant nonmalignant obstruction of the large veins. Copyright © 2013 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  4. Swine Model of Thrombotic Caval Occlusion Created by Autologous Thrombus Injection with Assistance of Intra-caval Net Knitting

    PubMed Central

    Shi, Wan-Yin; Wu, Shuang; Hu, Lan-Yue; Liu, Chang-Jian; Gu, Jian-Ping

    2015-01-01

    To evaluate the feasibility of a swine model of thrombotic inferior vena cava (IVC) occlusion (IVCO) created by autologous thrombus injection with assistance of intra-caval net knitting. Sixteen pigs were included and divided into two groups: Group A (n = 10), IVCO model created by knitting a caval net followed by autologous thrombus injection; Group B (n = 6), control model created by knitting a net and normal saline injection. Venography was performed to assess each model and the associated thrombotic occlusion. The vessels were examined histologically to analyse the pathological changes postoperatively. IVCO model was successfully created in 10 animals in Group A (100%). Immediate venography showed extensive clot burden in the IVC. Postoperative venography revealed partial caval occlusion at 7 days, and complete occlusion coupled with collateral vessels at 14 days. Histologically, Group A animals had significantly greater venous wall thickening, with CD163-positive and CD3-positive cell infiltration. Recanalization channels were observed at the margins of the thrombus. By contrast, no thrombotic occlusion of the IVC was observed in Group B. The thrombotic IVCO model can be reliably established in swine. The inflammatory reaction may contribute to the caval thrombus propagation following occlusion. PMID:26680253

  5. A Global Photoionization Response to Prompt Emission and Outliers: Different Origin of Long Gamma-ray Bursts?

    NASA Astrophysics Data System (ADS)

    Wang, J.; Xin, L. P.; Qiu, Y. L.; Xu, D. W.; Wei, J. Y.

    2018-03-01

    By using the line ratio C IV λ1549/C II λ1335 as a tracer of the ionization ratio of the interstellar medium (ISM) illuminated by a long gamma-ray burst (LGRB), we identify a global photoionization response of the ionization ratio to the photon luminosity of the prompt emission assessed by either L iso/E peak or {L}iso}/{E}peak}2. The ionization ratio increases with both L iso/E peak and L iso/E 2 peak for a majority of the LGRBs in our sample, although there are a few outliers. The identified dependence of C IV/C II on {L}iso}/{E}peak}2 suggests that the scatter of the widely accepted Amati relation is related to the ionization ratio in the ISM. The outliers tend to have relatively high C IV/C II values as well as relatively high C IV λ1549/Si IV λ1403 ratios, which suggests an existence of Wolf–Rayet stars in the environment of these LGRBs. We finally argue that the outliers and the LGRBs following the identified C IV/C II‑L iso/E peak ({L}iso}/{E}peak}2) correlation might come from different progenitors with different local environments.

  6. Overview of MPEG internet video coding

    NASA Astrophysics Data System (ADS)

    Wang, R. G.; Li, G.; Park, S.; Kim, J.; Huang, T.; Jang, E. S.; Gao, W.

    2015-09-01

    MPEG has produced standards that have provided the industry with the best video compression technologies. In order to address the diversified needs of the Internet, MPEG issued the Call for Proposals (CfP) for internet video coding in July, 2011. It is anticipated that any patent declaration associated with the Baseline Profile of this standard will indicate that the patent owner is prepared to grant a free of charge license to an unrestricted number of applicants on a worldwide, non-discriminatory basis and under other reasonable terms and conditions to make, use, and sell implementations of the Baseline Profile of this standard in accordance with the ITU-T/ITU-R/ISO/IEC Common Patent Policy. Three different codecs had responded to the CfP, which are WVC, VCB and IVC. WVC was proposed jointly by Apple, Cisco, Fraunhofer HHI, Magnum Semiconductor, Polycom and RIM etc. it's in fact AVC baseline. VCB was proposed by Google, and it's in fact VP8. IVC was proposed by several Universities (Peking University, Tsinghua University, Zhejiang University, Hanyang University and Korea Aerospace University etc.) and its coding tools was developed from Zero. In this paper, we give an overview of the coding tools in IVC, and evaluate its performance by comparing it with WVC, VCB and AVC High Profile.

  7. Experimental measurements of energy augmentation for mechanical circulatory assistance in a patient-specific Fontan model.

    PubMed

    Chopski, Steven G; Rangus, Owen M; Moskowitz, William B; Throckmorton, Amy L

    2014-09-01

    A mechanical blood pump specifically designed to increase pressure in the great veins would improve hemodynamic stability in adolescent and adult Fontan patients having dysfunctional cavopulmonary circulation. This study investigates the impact of axial-flow blood pumps on pressure, flow rate, and energy augmentation in the total cavopulmonary circulation (TCPC) using a patient-specific Fontan model. The experiments were conducted for three mechanical support configurations, which included an axial-flow impeller alone in the inferior vena cava (IVC) and an impeller with one of two different protective stent designs. All of the pump configurations led to an increase in pressure generation and flow in the Fontan circuit. The increase in IVC flow was found to augment pulmonary arterial flow, having only a small impact on the pressure and flow in the superior vena cava (SVC). Retrograde flow was neither observed nor measured from the TCPC junction into the SVC. All of the pump configurations enhanced the rate of power gain of the cavopulmonary circulation by adding energy and rotational force to the fluid flow. We measured an enhancement of forward flow into the TCPC junction, reduction in IVC pressure, and only minimally increased pulmonary arterial pressure under conditions of pump support. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  8. An outcome survey of 43 patients with Budd-Chiari syndrome due to Behçet's syndrome followed up at a single, dedicated center.

    PubMed

    Seyahi, Emire; Caglar, Erkan; Ugurlu, Serdal; Kantarci, Fatih; Hamuryudan, Vedat; Sonsuz, Abdullah; Melikoglu, Melike; Yurdakul, Sebahattin; Yazici, Hasan

    2015-04-01

    Behçet's syndrome (BS) is a well-recognized cause of Budd-Chiari syndrome (BCS); however, information about its clinical characteristics and outcome is limited. We reviewed the records of about 9000 patients with BS registered at the multidisciplinary Behçet's syndrome outpatient clinic at Cerrahpasa Medical Faculty between July 1977 and October 2013. We identified 43 (40 M/3 F) patients who were diagnosed as having BCS. Their outcome was evaluated between September 2012 and October 2013. In total, 33 patients (77%) had presented with liver-related symptoms (Group I), while 10 (23%) were asymptomatic for liver disease (Group II). This latter group had presented with symptoms related to the presence of major vessel disease such as fever, leg swelling, or dyspnea. The site of venous obstruction determined in 41 patients was inferior vena cava (IVC) and hepatic veins combined in 25 (61%), IVC alone in 12 (29%), and only hepatic veins in 4 patients (10%). The number of patients with concurrent obstruction in the hepatic veins and the IVC was less in Group II than in Group I (3/10 vs 22/31, p = 0.06). A total of 20 (19 M/1 F) patients (47%) had died at a median of 10 months after diagnosis. Mortality was significantly lower in Group II (10%) than in Group I (58%), (p = 0.011). By the end of the survey, 23 patients were alive, of whom 21 could be re-evaluated at the clinic. BCS associated with BS is usually due to IVC thrombosis with or without hepatic vein thrombosis. Silent cases exist and have a better prognosis. The mortality rate among the patients symptomatic for liver disease remains high. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Inferior Vena Cava Filters to Prevent Pulmonary Embolism: Systematic Review and Meta-Analysis.

    PubMed

    Bikdeli, Behnood; Chatterjee, Saurav; Desai, Nihar R; Kirtane, Ajay J; Desai, Mayur M; Bracken, Michael B; Spencer, Frederick A; Monreal, Manuel; Goldhaber, Samuel Z; Krumholz, Harlan M

    2017-09-26

    Inferior vena cava (IVC) filters are widely used for prevention of pulmonary embolism (PE). However, uncertainty persists about their efficacy and safety. The authors conducted a systematic review and meta-analysis of the published reports on the efficacy and safety of IVC filters. The authors searched PubMed, the Cochrane Central Register of Controlled Trials, and ClinicalTrials.gov through October 3, 2016, for randomized controlled trials (RCTs) or prospective controlled observational studies of IVC filters versus none in patients at risk of PE. Inverse variance fixed-effects models with odds ratio (OR) as the effect measure were used for primary analyses. Main outcomes included subsequent PE, PE-related mortality, all-cause mortality, and subsequent deep vein thrombosis (DVT). The authors' search retrieved 1,986 studies, of which 11 met criteria for inclusion (6 RCTs and 5 prospective observational studies). Quality of evidence for RCTs was low to moderate. Overall, patients receiving IVC filters had lower risk for subsequent PE (OR: 0.50; 95% confidence interval [CI]: 0.33 to 0.75); increased risk for DVT (OR: 1.70; 95% CI: 1.17 to 2.48); nonsignificantly lower PE-related mortality (OR: 0.51; 95% CI: 0.25 to 1.05); and no change in all-cause mortality (OR: 0.91; 95% CI: 0.70 to 1.19). Limiting the results to RCTs showed similar results. Findings were substantively similar across a wide range of sensitivity analyses. Very few prospective controlled studies, with limited quality of evidence, exist regarding the efficacy and safety of IVC filters. Overall, filters appear to reduce the risk of subsequent PE, increase the risk for DVT, and have no significant effect on overall mortality. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. Efficacy of Lower-Extremity Venous Thrombolysis in the Setting of Congenital Absence or Atresia of the Inferior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ganguli, Suvranu, E-mail: sganguli@partners.org; Kalva, Sanjeeva; Oklu, Rahmi

    Purpose: A rare but described risk factor for deep venous thrombosis (DVT), predominately in the young, is congenital agenesis or atresia of the inferior vena cava (IVC). The optimal management for DVT in this subset of patients is unknown. We evaluated the efficacy of pharmacomechanical catheter-directed thrombolysis (PCDT) followed by systemic anticoagulation in the treatment of acute lower-extremity DVT in the setting of congenital IVC agenesis or atresia. Materials and Methods: Between November of 2005 and May of 2010, six patients (three women [average age 21 years]) were referred to our department with acute lower-extremity DVT and subsequently found tomore » have IVC agenesis or atresia on magnetic resonance imaging. A standardized technique for PCDT (the Angiojet Rheolytic Thrombectomy System followed by the EKOS Microsonic Accelerated Thrombolysis System) was used for all subjects. Successful thrombolysis was followed by systemic heparinization with transition to Coumadin or low molecular-weight heparin and compression stockings. Subjects were followed-up at 1, 3, and then every 6 months after the procedure with clinical assessment and bilateral lower-extremity venous ultrasound. Results: All PCDT procedures were technically successful. No venous stenting or angioplasty was performed. The average thrombolysis time was 28.6 h (range 12-72). Two patients experienced heparin-induced thrombocytopenia, and one patient developed a self-limited knee hemarthrosis, No patients were lost to follow-up. The average length of follow-up was 25.8 {+-} 20.2 months (range 3.8-54.8). No incidence of recurrent DVT was identified. There were no manifestations of postthrombotic syndrome. Conclusions: PCDT followed by systemic anticoagulation and the use of compression stockings appears to be safe and effective in relatively long-term follow-up treatment of patients who present with acute DVT and IVC agenesis or atresia.« less

  11. Epithelialization and stromalization of porcine follicular granulosa cells during real-time proliferation - a primary cell culture approach.

    PubMed

    Ciesiółka, S; Bryja, A; Budna, J; Kranc, W; Chachuła, A; Bukowska, D; Piotrowska, H; Porowski, L; Antosik, P; Bruska, M; Brüssow, K P; Nowicki, M; Zabel, M; Kempisty, B

    2016-01-01

    The process of oocyte growth and development takes place during long stages of folliculogenesis and oogenesis. This is accompanied by biochemical and morphological changes, occurring from the preantral to antral stages during ovarian follicle differentiation. It is well known that the process of follicle growth is associated with morphological modifications of theca (TCs) and granulosa cells (GCs). However, the relationship between proliferation and/or differentiation of porcine GCs during long-term in vitro culture requires further investigation. Moreover, the expression of cytokeratins and vimentin in porcine GCs, in relation to real-time cell proliferation, has yet to be explored. Utilizing confocal microscopy, we analyzed cytokeratin 18 (CK18), cytokeratin 8 + 18 + 19 (panCK), and vimentin (Vim) expression, as well as their protein distribution, within GCs isolated from slaughtered ovarian follicles. The cells were cultured for 168 h with protein expression and cell proliferation index analyzed at 24-h intervals. We found the highest expression of CK18, panCK, and Vim occurred at 120 h of in vitro culture (IVC) as compared with other experimental time intervals. All of the investigated proteins displayed cytoplasmic distribution. Analysis of real-time cell proliferation revealed an increased cell index after the first 24 h of IVC. Additionally, during each period between 24-168 h of IVC, a significant difference in the proliferation profile, expressed as the cell index, was also observed. We concluded that higher expression of vimentin at 120 h of in vitro proliferation might explain the culmination of the stromalization process associated with growth and domination of stromal cells in GC culture. Cytokeratin expression within GC cytoplasm confirms the presence of epithelial cells as well as epithelial-related GC development during IVC. Moreover, expression of both cytokeratins and vimentin during short-term culture suggests that the process of GC proliferation is also highly associated with porcine ovarian follicular granulosa cell differentiation in vitro.

  12. Cetuximab and Everolimus in Treating Patients With Metastatic or Recurrent Colon Cancer or Head and Neck Cancer

    ClinicalTrials.gov

    2012-07-06

    Recurrent Adenoid Cystic Carcinoma of the Oral Cavity; Recurrent Basal Cell Carcinoma of the Lip; Recurrent Colon Cancer; Recurrent Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Recurrent Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Recurrent Lymphoepithelioma of the Nasopharynx; Recurrent Lymphoepithelioma of the Oropharynx; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Recurrent Mucoepidermoid Carcinoma of the Oral Cavity; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Stage IV Adenoid Cystic Carcinoma of the Oral Cavity; Stage IV Basal Cell Carcinoma of the Lip; Stage IV Lymphoepithelioma of the Nasopharynx; Stage IV Lymphoepithelioma of the Oropharynx; Stage IV Mucoepidermoid Carcinoma of the Oral Cavity; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Larynx; Stage IV Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IV Squamous Cell Carcinoma of the Oropharynx; Stage IV Verrucous Carcinoma of the Larynx; Stage IV Verrucous Carcinoma of the Oral Cavity; Stage IVA Colon Cancer; Stage IVA Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Stage IVA Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Colon Cancer; Stage IVB Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Stage IVB Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Stage IVC Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Tongue Cancer

  13. Community-acquired necrotizing pneumonia caused by methicillin-resistant Staphylococcus aureus ST30-SCCmecIVc-spat019-PVL positive in San Antonio de Areco, Argentina.

    PubMed

    Fernandez, Silvina; Murzicato, Sofía; Sandoval, Orlando; Fernández-Canigia, Liliana; Mollerach, Marta

    2015-01-01

    Community-acquired methicillin-resistant Staphylococcus aureus is the first cause of skin and soft tissue infections, but can also produce severe diseases such as bacteremia, osteomyelitis and necrotizing pneumonia. Some S. aureus lineages have been described in cases of necrotizing pneumonia worldwide, usually in young, previously healthy patients. In this work, we describe a fatal case of necrotizing pneumonia due to community-acquired methicillin-resistant S. aureus clone ST30-SCCmecIVc-spat019-PVL positive in an immunocompetent adult patient. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Isolated metastases of hepatocellular carcinoma in the right atrium: Case report and review of the literature

    PubMed Central

    KAWAKAMI, MANRI; KODA, MASAHIKO; MANDAI, MARI; HOSHO, KEIKO; MURAWAKI, YOSHIKAZU; ODA, WAKAKO; HAYASHI, KAZUHIKO

    2013-01-01

    The aim of this study was to clarify the clinical features of patients with isolated HCC metastases to the heart. A 66-year-old female hospitalized with a hepatocellular carcinoma (HCC) ranging from the right to the left lobe and with a tumor thrombus in the main portal vein, was treated with intraarterial cisplatin, 5-fluouracil, adriamycin and mitomycin. Computed tomography (CT) one month later revealed that the HCC had progressed with multiple lung metastases and moderate ascites. The patient had no symptoms. Magnetic resonance imaging (MRI) and echocardiography revealed a round, movable tumor with a diameter of 2 cm in the right atrium (RA). The patient succumbed to HCC five months later. An autopsy revealed HCC with portal tumor thrombi and metastases to the lungs, inferior vena cava (IVC) and RA. The metastases in the RA and IVC were not continous with the intrahepatic tumor and were histologically attached to the endocardium and endothelium, respectively. An isolated metastasis of a HCC of the RA and IVC is extremely rare. In conclusion, although the majority of isolated metastases of HCC to the heart were diagnosed by echocardiography and were treated with mainly surgery, they had poor prognosis. The echocardiography should be performed for patients with advanced HCC. A novel treatment including molecular targeted drugs is required. PMID:23760591

  15. Deep vein thrombus formation induced by flow reduction in mice is determined by venous side branches.

    PubMed

    Brandt, Moritz; Schönfelder, Tanja; Schwenk, Melanie; Becker, Christian; Jäckel, Sven; Reinhardt, Christoph; Stark, Konstantin; Massberg, Steffen; Münzel, Thomas; von Brühl, Marie-Luise; Wenzel, Philip

    2014-01-01

    Interaction between vascular wall abnormalities, inflammatory leukocytes, platelets, coagulation factors and hemorheology in the pathogenesis of deep vein thrombosis (DVT) is incompletely understood, requiring well defined animal models of human disease. We subjected male C57BL/6 mice to ligation of the inferior vena cava (IVC) as a flow reduction model to induce DVT. Thrombus size and weight were analyzed macroscopically and sonographically by B-mode, pulse wave (pw) Doppler and power Doppler imaging (PDI) using high frequency ultrasound. Thrombus size varied substantially between individual procedures and mice, irrespective of the flow reduction achieved by the ligature. Interestingly, PDI accurately predicted thrombus size in a very robust fashion (r2 = 0.9734, p < 0.0001). Distance of the insertion of side branches from the ligature significantly determines thrombus weight (r2 = 0.5597, p < 0.0001) and length (r2 = 0.5441, p < 0.0001) in the IVC, regardless of the flow measured by pw-Doppler with distances <1.5 mm drastically impairing thrombus formation. Occlusion of side branches prior to ligation of IVC did not increase thrombus size, probably due to patent side branches inaccessible to surgery. Venous side branches influence thrombus size in experimental DVT and might therefore prevent thrombus formation. This renders vessel anatomy and hemorheology important determinants in mouse models of DVT, which should be controlled for.

  16. Early and Late Retrieval of the ALN Removable Vena Cava Filter: Results from a Multicenter Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pellerin, O., E-mail: olivier.pellerin@egp.aphp.f; Barral, F. G.; Lions, C.

    Retrieval of removable inferior vena cava (IVC) filters in selected patients is widely practiced. The purpose of this multicenter study was to evaluate the feasibility and results of percutaneous removal of the ALN removable filter in a large patient cohort. Between November 2003 and June 2006, 123 consecutive patients were referred for percutaneous extraction of the ALN filter at three centers. The ALN filter is a removable filter that can be implanted through a femoral/jugular vein approach and extracted by the jugular vein approach. Filter removal was attempted after an implantation period of 93 {+-} 15 days (range, 6-722 days)more » through the right internal jugular vein approach using the dedicated extraction kit after control inferior vena cavography. Following filter removal, vena cavograms were obtained in all patients. Successful extraction was achieved in all but one case. Among these successful retrievals, additional manipulation using a femoral approach was needed when the apex of the filter was close to the IVC wall in two patients. No immediate IVC complications were observed according to the postimplantation cavography. Neither technical nor clinical differences between early and late filter retrieval were noticed. Our data confirm the safety of ALN filter retrieval up to 722 days after implantation. In infrequent cases, additional endovenous filter manipulation is needed to facilitate extraction.« less

  17. 22 CFR 121.5 - Apparatus and devices under Category IV(c).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and..., intervalometers, thermal batteries, hardened missile launching facilities, guided missile launchers and...

  18. 22 CFR 121.5 - Apparatus and devices under Category IV(c).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and..., intervalometers, thermal batteries, hardened missile launching facilities, guided missile launchers and...

  19. 22 CFR 121.5 - Apparatus and devices under Category IV(c).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and..., intervalometers, thermal batteries, hardened missile launching facilities, guided missile launchers and...

  20. VX-970, Cisplatin, and Radiation Therapy in Treating Patients With Locally Advanced HPV-Negative Head and Neck Squamous Cell Carcinoma

    ClinicalTrials.gov

    2018-06-11

    Head and Neck Squamous Cell Carcinoma; Human Papillomavirus Negative; Stage III Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v6 and v7; Stage III Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IV Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IV Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVA Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVB Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVC Oropharyngeal Squamous Cell Carcinoma AJCC v7

  1. Cediranib Maleate With or Without Lenalidomide in Treating Patients With Thyroid Cancer

    ClinicalTrials.gov

    2018-05-23

    Recurrent Thyroid Gland Carcinoma; Stage I Thyroid Gland Follicular Carcinoma AJCC v7; Stage I Thyroid Gland Papillary Carcinoma AJCC v7; Stage II Thyroid Gland Follicular Carcinoma AJCC v7; Stage II Thyroid Gland Papillary Carcinoma AJCC v7; Stage III Thyroid Gland Follicular Carcinoma AJCC v7; Stage III Thyroid Gland Papillary Carcinoma AJCC v7; Stage IV Thyroid Gland Follicular Carcinoma AJCC v7; Stage IV Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVA Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVA Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVB Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVB Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVC Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVC Thyroid Gland Papillary Carcinoma AJCC v7

  2. Transfemoral Filter Eversion Technique following Unsuccessful Retrieval of Option Inferior Vena Cava Filters: A Single Center Experience.

    PubMed

    Posham, Raghuram; Fischman, Aaron M; Nowakowski, Francis S; Bishay, Vivian L; Biederman, Derek M; Virk, Jaskirat S; Kim, Edward; Patel, Rahul S; Lookstein, Robert A

    2017-06-01

    This report describes the technical feasibility of using the filter eversion technique after unsuccessful retrieval attempts of Option and Option ELITE (Argon Medical Devices, Inc, Athens, Texas) inferior vena cava (IVC) filters. This technique entails the use of endoscopic forceps to evert this specific brand of IVC filter into a sheath inserted into the common femoral vein, in the opposite direction in which the filter is designed to be removed. Filter eversion was attempted in 25 cases with a median dwell time of 134 days (range, 44-2,124 d). Retrieval success was 100% (25/25 cases), with an overall complication rate of 8%. This technique warrants further study. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  3. A computational investigation of diesel and biodiesel combustion and NOx formation in a light-duty compression ignition engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zihan; Srinivasan, Kalyan K.; Krishnan, Sundar R.

    Diesel and biodiesel combustion in a multi-cylinder light duty diesel engine were simulated during a closed cycle (from IVC to EVO), using a commercial computational fluid dynamics (CFD) code, CONVERGE, coupled with detailed chemical kinetics. The computational domain was constructed based on engine geometry and compression ratio measurements. A skeletal n-heptane-based diesel mechanism developed by researchers at Chalmers University of Technology and a reduced biodiesel mechanism derived and validated by Luo and co-workers were applied to model the combustion chemistry. The biodiesel mechanism contains 89 species and 364 reactions and uses methyl decanoate, methyl-9- decenoate, and n-heptane as the surrogatemore » fuel mixture. The Kelvin-Helmholtz and Rayleigh-Taylor (KH-RT) spray breakup model for diesel and biodiesel was calibrated to account for the differences in physical properties of the fuels which result in variations in atomization and spray development characteristics. The simulations were able to capture the experimentally observed pressure and apparent heat release rate trends for both the fuels over a range of engine loads (BMEPs from 2.5 to 10 bar) and fuel injection timings (from 0° BTDC to 10° BTDC), thus validating the overall modeling approach as well as the chemical kinetic models of diesel and biodiesel surrogates. Moreover, quantitative NOx predictions for diesel combustion and qualitative NOx predictions for biodiesel combustion were obtained with the CFD simulations and the in-cylinder temperature trends were correlated to the NOx trends.« less

  4. Intraventricular Hemorrhage in Adults.

    PubMed

    Naff

    1999-07-01

    Intraventricular hemorrhage (IVH) in adults usually occurs in the setting of aneurysmal subarachnoid hemorrhage or hypertension-related intracerebral hemorrhage. Thus, the underlying cause of IVH is apparent from history and radiographic findings. If the underlying cause of IVH is not apparent, additional studies, including cerebral angiography, magnetic resonance imaging, and toxicology screening, should be performed to identify etiologic agents that may alter management of IVH. Management of IVH is thus done amidst (and must be tempered by) the multiple pharmacologic, surgical, and critical care interventions directed toward the diagnosis and treatment of the underlying cause of IVH. The most immediate threat to life posed by IVH is the development of acute obstructive hydrocephalus. If the hydrocephalus is contributing to a neurologic decline, it must be treated emergently with external ventricular drainage (EVD) through an intraventricular catheter (IVC). The patient with IVH should be evaluated and treated for deficient clotting function before an IVC is inserted. For this purpose, clotting function can be adequately assessed by prothrombin and partial thromboplastin times. Insertion of an IVC may significantly lower intracranial pressure, increasing the transmural pressure difference across the wall of a ruptured cerebral aneurysm and precipitating rerupture of the aneurysm. Therefore, with IVH secondary to a ruptured cerebral aneurysm, it is advisable to delay treatment of hydrocephalus that is not contributing to a neurologic decline until the aneurysm is repaired. Hydrocephalus contributing to significant neurologic decline in the setting of a ruptured aneurysm must be treated immediately despite the unprotected status of the aneurysm. Extreme diligence must be used to allow for the slow, controlled release of cerebrospinal fluid after IVC insertion. This will mitigate the effects of increasing the transmural pressure gradient across the wall of the ruptured aneurysm. In the patient with a neurologic deficit who has IVH-related hydrocephalus and an associated intracerebral hemorrhage, it is best to assume that the hydrocephalus is a significant contributor to the deficit and that it should be treated with EVD. An IVH that is not causing hydrocephalus but is apparently occluding one or both foramina of Monro or the third ventricle should be treated with EVD because obstructive hydrocephalus may develop precipitously and, if unrecognized, may cause irreversible brain damage or death. An IVH that is not likely to cause hydrocephalus because of small volume relative to its location can be followed expectantly. Intraventricular injections of thrombolytic agents through an IVC is a treatment option that may be considered in all patients with IVH that is causing or threatening to cause obstructive hydrocephalus. Unrepaired cerebral aneurysms, untreated cerebral arteriovenous malformations, and clotting disorders are contraindications for this intervention. The surgical evacuation of IVH has a role only in very rare cases in which the IVH is causing a significant mass effect independent of hydrocephalus and associated intraparenchymal brain hemorrhage.

  5. Molecular Typing and Virulence Characteristic of Methicillin-Resistant Staphylococcus Aureus Isolates from Pediatric Patients in Bucaramanga, Colombia

    PubMed Central

    Machuca, Mayra Alejandra; Sosa, Luis Miguel; González, Clara Isabel

    2013-01-01

    Background Staphylococcus aureus is among the most common global nosocomial pathogens. The emergence and spread of methicillin-resistant Staphylococcus aureus (MRSA) is a public health problem worldwide that causes nosocomial and community infections. The goals of this study were to establish the clonal complexes (CC) of the isolates of MRSA obtained from pediatric patients in a university hospital in Colombia and to investigate its molecular characteristics based on the virulence genes and the genes of staphylococcal toxins and adhesins. Methods A total of 53 MRSA isolates from pediatric patients with local or systemic infections were collected. The MRSA isolates were typed based on the SCCmec, MLST, spa and agr genes. The molecular characterization included the detection of Panton-Valentine Leukocidin, superantigenic and exfoliative toxins, and adhesin genes. The correlation between the molecular types identified and the profile of virulence factors was determined for all isolates. Results Four CC were identified, including CC8, CC5, CC80 and CC78. The ST8-MRSA-IVc-agrI was the predominant clone among the isolates, followed by the ST5-MRSA-I-agrII and ST5-MRSA-IVc-agrII clones. Twelve spa types were identified, of which t10796 and t10799 were new repeat sequences. The isolates were carriers of toxin genes, and hlg (100%), sek (92%) and pvl (88%) were the most frequent. Ten toxin gene profiles were observed, and the most frequent were seq-sek-hlg (22.6%), sek-hlg (22.6%), seb-seq-sek-hlg (18.9%) and seb-sek-hlg (15.1%). The adhesion genes were present in most of the MRSA isolates, including the following: clf-A (89%), clf-B (87%), fnb-A (83%) and ica (83%). The majority of the strains carried SCCmec-IVc and were identified as causing nosocomial infection. No significant association between a molecular type and the virulence factors was found. Conclusion Four major MRSA clone complexes were identified among the isolates. ST8-MRSA-IVc-agrI pvl+ (USA300-LV) was the most frequent, confirming the presence of community-associated MRSA in Colombian hospitals. PMID:24058415

  6. SU-F-207-07: Dual-Energy Computed Tomography Detection Limit of Various Radiopaque Contrast Agents That Can Be Infused Within Absorbable Inferior Vena Cava Filters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Melancon, A; Jacobsen, M; Salatan, F

    Purpose: Absorbable IVC filters are shown to be safe and efficacious in preventing pulmonary embolism. These absorbable filters disappear from the body after their required duration, alleviating costly removal procedures and downstream complications. Monitoring the positioning and integrity of absorbable devices using dual-energy computed tomography (DECT) would improve treatment efficacy. The purpose of this study is to determine the limit of detection and the energy dependence of DECT for various contrast agents that may be infused within the IVC filters including gold nanoparticles (AuNP) having diameters of 2 and 4 nm. Methods: All imaging studies were performed on a GEmore » Discovery CT750 system in Gemstone Spectral Imaging (GSI) mode. Plastic vials containing the contrast agent solutions of water and blood were placed in a water bath, and images were acquired with the GSI-5 preset. The images were reformatted into the coronal plane and 5mm diameter ROIs were placed within each solution on a GE Advantage Workstation. Monoenergetic reconstructions were generated from 40 – 140 keV. Results: Mass attenuation (contrast per unit density) for AuNPs was greater than iron, but less than barium and iodine. Contrast was 10.2 (± 3.6) HU for 4 nm AuNP at 0.72 mg/ml and 12.1 (± 4.2) for 2 nm AuNP at 0.31 mg/ml at 70 keV suggesting reasonable chance of visualization at these concentrations for 70 keV reconstruction. The contrast as a function of CT energy is similar in both water and blood. Iodine is most dependent, followed closely by barium and iron, and trailed by a large margin by the AuNP. This was unexpected given Au’s large atomic number and the predominance of photoelectric effect at low energy. Conclusion: Infusion of IVC filters with AuNP is feasible. Discrimination of AuNP-infused IVC filters from surrounding anatomy warrants further investigation.« less

  7. 76 FR 14923 - Endangered and Threatened Species; Take of Anadromous Fish

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ... (i.e., surface and bottom water temperature, salinity, near bottom dissolved oxygen concentration...-water and bottom trawls) are adequately characterizing schools of hake. The IVC research would take...

  8. A pilot study to monitor changes in spirometry and lung volume, following an exacerbation of Chronic Obstructive Pulmonary Disease (COPD), as part of a supported discharge program.

    PubMed

    Cushen, Breda; McCormack, Niamh; Hennigan, Kerrie; Sulaiman, Imran; Costello, Richard W; Deering, Brenda

    2016-10-01

    One-third of patients with an exacerbation of Chronic Obstructive Pulmonary Disease(COPD) are re-hospitalised at 90 days. Exacerbation recovery is associated with reductions in lung hyperinflation and improvements in symptoms and physical activity. We assessed the feasibility of monitoring these clinical parameters in the home. We hypothesised that the degree of change in spirometry and lung volumes differs between those who had an uneventful recovery and those who experienced a further exacerbation. Hospitalised patients with an acute exacerbation of COPD referred for a supported discharge program participated in the study. Spirometry and Inspiratory Vital Capacity(IVC) were measured in the home at Days 1, 14 and 42 post-discharge. Patients also completed Medical Research Council(MRC), Borg and COPD Assessment Test(CAT) scores and were provided with a tri-axial accelerometer. Any new exacerbation events were recorded. Sixty-five patients with 72 exacerbation episodes were recruited. Fifty percent experienced a second exacerbation. Adequate IVC measurements were achieved by 90%, while only 70% completed spirometry. Uneventful recovery was accompanied by significant improvements in physiological measurements at day14, improved symptom scores and step count, p < 0.05. Failure of MRC to improve was predictive of re-exacerbation(Area Under Receiver Operating Curve(AUROC) 0.6713) with improvements in FEV 1 ≥100 ml(AUROC 0.6613) and mean daily step count ≥396 steps(AUROC 0.6381) predictive of recovery. Monitoring the pattern of improvement in spirometry, lung volumes, symptoms and step count following a COPD exacerbation may help to identify patients at risk of re-exacerbation. It is feasible to carry out these assessments in the home as part of a supported discharge programme. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. 22 CFR 121.5 - Apparatus and devices under Category IV(c).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., modified or configured for items listed in that category, bomb racks and shackles, bomb shackle release units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and...

  10. Inferior Vena Cava Filter Placement and Removal

    MedlinePlus

    ... Professions Site Index A-Z Inferior Vena Cava Filter Placement and Removal During Inferior Vena Cava (IVC) ... benefits vs. risks? What is Inferior Vena Cava Filter Placement and Removal? In an inferior vena cava ...

  11. The need for venovenous bypass in liver transplantation

    PubMed Central

    Fonouni*, Hamidreza; Soleimani, Mehrdad; Müller, Sascha A.; Büchler, Markus W.; Schmidt, Jan

    2008-01-01

    Since introduction of the conventional liver transplantation (CLTx) by Starzl, which was based on the resection of recipient inferior vena cava (IVC) along the liver, the procedure has undergone several refinements. Successful use of venovenous bypass (VVB) was first introduced by Shaw et al., although in recent decades there has been controversy regarding the routine use of VVB during CLTx. With development of piggyback liver transplantation (PLTx), the use of caval clamping and VVB is avoided, leading to fewer complications related to VVB. However, some authors still advocate VVB in PLTx. The great diversity among centers in their use of VVB during CLTx, or even along the PLTx technique, has led to confusion regarding the indication setting for VVB. For this reason, we present an overview of the use of VVB in CLTx, the target of patients for whom VVB could be beneficial, and the needs assessment of VVB for patients undergoing PLTx. Recent studies have shown that with the advancement of surgical skills, refinement of surgical techniques, and improvements in anesthesiology, there are only limited indications for doing CLTx with VVB routinely. PLTx with preservation of IVC can be performed in almost all primary transplants and in the majority of re-transplantations without the need for VVB. Nevertheless, in a few selective cases with severe intra-operative hemodynamic instability, or with a failed test of transient IVC occlusion, the application of VVB is still justifiable. These indications should be judged intra-operatively and the decision is based on each center's preference. PMID:18773054

  12. Cannulation for veno-venous extracorporeal membrane oxygenation

    PubMed Central

    2018-01-01

    Extracorporeal membrane oxygenation (ECMO) is described as a modified, smaller cardiopulmonary bypass circuit. The veno-venous (VV) ECMO circuit drains venous blood, oxygenate the blood, and pump the blood back into the same venous compartment. Draining and reinfusing in the same compartment means there are a risk of recirculation. The draining position within the venous system, ECMO pump flow, return flow position within the venous system and the patients cardiac output (CO) all have an impact on recirculation. Using two single lumen cannulas or one dual lumen cannula, but also the design of the venous cannula, can have an impact on where within the venous system the cannula is draining blood and will affect the efficiency of the ECMO circuit. VV ECMO can be performed with different cannulation strategies. The use of two single lumen cannulas draining in inferior vena cava (IVC) and reinfusing in superior vena cava (SVC) or draining in SVC and reinfusing in IVC, or one dual lumen cannula inserted in right jugular vein is all possible cannulation strategies. Independent of cannulation strategy there will be a risk of recirculation. Efficiency can be reasonable in either strategy if the cannulas are carefully positioned and monitored during the dynamic procedure of pulmonary disease. The disadvantage draining from IVC only occurs when there is a need for converting from VV to veno-arterial (VA) ECMO, reinfusing in the femoral artery. Then draining from SVC is the most efficient strategy, draining low saturated venous blood, and also means low risk of dual circulation. PMID:29732177

  13. Topographic anatomy of the fetal inferior vena cava, coronary sinus, and pulmonary veins: Variations in Chiari's network.

    PubMed

    Naito, Michiko; Yu, Hee Chul; Kim, Ji Hyun; Rodríguez-Vázquez, José Francisco; Murakami, Gen; Cho, Baik Hwan

    2015-07-01

    To understand anomalies in Chiari's network better, we assessed the topographical anatomy of the fetal inferior vena cava (IVC), coronary sinus, and atria. We examined sagittal serial paraffin sections of 15 human fetuses of crown-rump length 24-36 mm, corresponding to a gestational age of 8 weeks. Although their outflow tract morphologies were similar, these 15 specimens could be classified into two groups. In eight specimens, the left common cardinal vein reached the body wall, whereas in the other seven the vein was obliterated near the left pulmonary vein. Irrespective of the group in which the specimen was included, the anteroposterior arrangement of the coronary sinus, the sinus septum (septum), and the right sinus valve (right valve) could be classified into three types: the right valve-septum-coronary sinus arrangement in seven specimens; the right valve-coronary sinus-septum arrangement in five; and the coronary sinus-right valve-septum arrangement in three. Depending on differences in topographical anatomy, the sinus septum separated the coronary sinus opening from either the right or the left atrium. Likewise, the coronary sinus opening was either adjacent to or distant from the IVC terminal. Rather than the counter-side position of the right valve being at the IVC terminal, the left sinus valve protruded leftward, forming an incomplete interatrial septum. Fetal variations seemed to be closely connected with individual variations and a high frequency of Chiari's network anomalies in adults. © 2014 Wiley Periodicals, Inc.

  14. Transplantation of an alginate-matrigel matrix containing isolated ovarian cells: first step in developing a biodegradable scaffold to transplant isolated preantral follicles and ovarian cells.

    PubMed

    Vanacker, Julie; Luyckx, Valérie; Dolmans, Marie-Madeleine; Des Rieux, Anne; Jaeger, Jonathan; Van Langendonckt, Anne; Donnez, Jacques; Amorim, Christiani A

    2012-09-01

    For women diagnosed with leukemia, transplantation of cryopreserved ovarian tissue after disease remission is not advisable. Therefore, to restore fertility in these patients, we aim to develop a biodegradable artificial ovary that offers an environment where isolated follicles and ovarian cells (OCs) can survive and grow. Four NMRI mice were ovariectomized and their ovaries used to isolate OCs. Groups of 50,000 OCs were embedded in an alginate-matrigel matrix for further fixation (fresh controls), one week of in vitro culture (IVC) or heterotopic autografting. OC proliferation (Ki67), apoptosis (TUNEL), scaffold degradation, vessel formation (CD34) and inflammation (CD45) were analyzed. Ki67-positive OCs were found in 2.3%, 9.0% and 15.5% cells of cases in fresh, IVC and grafted beads respectively, while cells were TUNEL-positive in 0%, 1.5% and 6.9% of cases. After IVC or grafting, the beads degraded, losing their original round aspect, and infiltrating blood capillaries could be observed in the grafted beads. CD34-positive cells and 22% CD45-positive cells were found around and inside the matrix. In conclusion, our results demonstrate that an alginate-based matrix is a promising proposition to graft isolated OCs. After transplantation, this matrix was able to degrade, allowed vascularization and elicited a low inflammatory response. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Resveratrol-cyclodextrin complex affects the expression of genes associated with lipid metabolism in bovine in vitro produced embryos.

    PubMed

    Torres, V; Hamdi, M; Millán de la Blanca, M G; Urrego, R; Echeverri, J; López-Herrera, A; Rizos, D; Gutiérrez-Adán, A; Sánchez-Calabuig, M J

    2018-03-26

    Antioxidants have been widely used during in vitro production to decrease the negative effect of reactive oxygen species. It was reported that the complex resveratrol-methyl β-cyclodextrin (RV-CD) improves resveratrol's stability and bioavailability and increases its antioxidant activity. This study evaluates the effect of RV-CD during in vitro oocyte maturation (IVM) or in vitro embryo culture (IVC) on developmental competence and quantitative changes in gene expression of developmental important genes. In experiment 1, RV-CD was added to IVM media and maturation level, embryo development and oocytes, cumulus cells, and blastocysts gene expression by RT-qPCR were examined. In experiment 2, presumptive zygotes were cultured in SOF supplemented with RV-CD and embryo development and blastocysts gene expression by RT-qPCR were studied. A group without RV-CD (control - ) and a group with cyclodextrin (control + ) were included. No differences were found in cleavage rate or blastocyst yield between groups. However, the expression of LIPE was higher in blastocysts derived from oocytes treated with resveratrol compared with control groups (p < .05). Blastocysts produced by IVC with resveratrol showed that RV-CD could modify the expression of genes related to lipid metabolism (CYP51A1, PNPLA2 and MTORC1) compared with control groups (p < .05). RV-CD in the IVM and IVC media could reduce accumulated fat by increasing lipolysis and suppressing lipogenesis of blastocysts. © 2018 Blackwell Verlag GmbH.

  16. Erlotinib in Treating Patients With Advanced Non-Small Cell Lung Cancer, Ovarian Cancer, or Squamous Cell Carcinoma of the Head and Neck

    ClinicalTrials.gov

    2013-01-08

    Recurrent Non-small Cell Lung Cancer; Recurrent Ovarian Epithelial Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage IIIA Non-small Cell Lung Cancer; Stage IIIA Ovarian Epithelial Cancer; Stage IIIB Non-small Cell Lung Cancer; Stage IIIB Ovarian Epithelial Cancer; Stage IIIC Ovarian Epithelial Cancer; Stage IV Non-small Cell Lung Cancer; Stage IV Ovarian Epithelial Cancer; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx

  17. Diagnostic performance of multi-organ ultrasound with pocket-sized device in the management of acute dyspnea.

    PubMed

    Sforza, Alfonso; Mancusi, Costantino; Carlino, Maria Viviana; Buonauro, Agostino; Barozzi, Marco; Romano, Giuseppe; Serra, Sossio; de Simone, Giovanni

    2017-06-19

    The availability of ultra-miniaturized pocket ultrasound devices (PUD) adds diagnostic power to the clinical examination. Information on accuracy of ultrasound with handheld units in immediate differential diagnosis in emergency department (ED) is poor. The aim of this study is to test the usefulness and accuracy of lung ultrasound (LUS) alone or combined with ultrasound of the heart and inferior vena cava (IVC) using a PUD for the differential diagnosis of acute dyspnea (AD). We included 68 patients presenting to the ED of "Maurizio Bufalini" Hospital in Cesena (Italy) for AD. All patients underwent integrated ultrasound examination (IUE) of lung-heart-IVC, using PUD. The series was divided into patients with dyspnea of cardiac or non-cardiac origin. We used 2 × 2 contingency tables to analyze sensitivity, specificity, positive predictive value and negative predictive value of the three ultrasonic methods and their various combinations for the diagnosis of cardiogenic dyspnea (CD), comparing with the final diagnosis made by an independent emergency physician. LUS alone exhibited a good sensitivity (92.6%) and specificity (80.5%). The highest accuracy (90%) for the diagnosis of CD was obtained with the combination of LUS and one of the other two methods (heart or IVC). The IUE with PUD is a useful extension of the clinical examination, can be readily available at the bedside or in ambulance, requires few minutes and has a reliable diagnostic discriminant ability in the setting of AD.

  18. 3. EASTERN EDGE OF POST ENGINEER'S SHOPS AND YARD, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. EASTERN EDGE OF POST ENGINEER'S SHOPS AND YARD, LOOKING 312 DEGREES NORTH WEST, EUCALYPTUS TREES DENOTE EDGE OF PRESIDIO. - Presidio of San Francisco, Post Engineer's Headquarters Office, Crissy Field North cantonment, San Francisco, San Francisco County, CA

  19. Reduced-Dose Intensity-Modulated Radiation Therapy With or Without Cisplatin in Treating Patients With Advanced Oropharyngeal Cancer

    ClinicalTrials.gov

    2018-01-08

    Stage III Oropharyngeal Squamous Cell Carcinoma; Stage IVA Oropharyngeal Squamous Cell Carcinoma; Stage IVB Oropharyngeal Squamous Cell Carcinoma; Stage IVC Oropharyngeal Squamous Cell Carcinoma; Tongue Carcinoma

  20. Rosuvastatin reduced deep vein thrombosis in ApoE gene deleted mice with hyperlipidemia through non-lipid lowering effects

    PubMed Central

    Patterson, K.A.; Zhang, X.; Wrobleski, S.K.; Hawley, A.E.; Lawrence, D. A.; Wakefield, T.W.; Myers, D.D.; Diaz, J.A.

    2013-01-01

    Introduction Statins, particularly rosuvastatin, have recently become relevant in the setting of venous thrombosis. The objective of this study was to study the non-lipid lowering effects of rosuvastatin in venous thrombosis in mice with hyperlipidemia. Materials and Methods An inferior vena cava ligation model of venous thrombosis in mice was utilized. Saline or 5mg/kg of rosuvastatin was administered by gavage 48hs previous thrombosis. Blood, the inferior vena cava, thrombus, and liver were harvested 3, 6 hours, and 2 days post-thrombosis. Thrombus weight, inflammatory markers, and plasminogen activator inhibitor-1 expression and plasma levels were measured and neutrophil migration to the IVC was assessed. Results Rosuvastatin significantly decreased thrombus weight, plasminogen activator inhibitor-1 expression and plasma levels, expression of molecules related to the interleukin-6 pathway, and neutrophil migration into the vein wall. Conclusions This work supports the beneficial effects of rosuvastatin on venous thrombosis in mice with hyperlipidemia due to its non-lipid lowering effects. PMID:23276528

  1. 40 CFR 60.4171 - Initial certification and recertification procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and Compliance Times for Coal-Fired Electric Steam Generating Units Monitoring and Reporting § 60.4171... disapproval under paragraph (c)(3)(iv)(C) of this section. The 120-day review period shall not begin before...

  2. 40 CFR 60.4171 - Initial certification and recertification procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and Compliance Times for Coal-Fired Electric Steam Generating Units Monitoring and Reporting § 60.4171... disapproval under paragraph (c)(3)(iv)(C) of this section. The 120-day review period shall not begin before...

  3. Teaching lens, optical systems, and opto-mechanical systems design at the Irvine Center for Applied Competitive Technologies (CACT)

    NASA Astrophysics Data System (ADS)

    Doushkina, Valentina V.; Silberman, Donn M.

    2007-09-01

    For well over a decade, the Laser Electro-Optics Technology (LET) program has been teaching introductory laser and optics classes at Irvine Valley College (IVC). At the beginning of the telecom boom, the Irvine CACT was established to teach optics fabrication to support the many optics fabrication businesses in Southern California. In the past few years, these two programs have merged - with some help from the Optics Institute of Southern California (OISC) - and grown under the newly established Advanced Technology and Education Park (ATEP). IVC and ATEP are both operated by the South Orange County Community College District (SOCCCD). This year a new program of three courses was established to teach, in sequence, lens, optical systems and optomechanical systems design. This paper reviews the reasons for establishing these courses and their content, the students' motivations for taking them and their employers' incentives for encouraging the students.

  4. Unusual case of subxiphoid uniportal VATS right upper lobectomy in a patient with interrupted inferior vena cava with azygous continuation

    PubMed Central

    Abu Akar, Firas Emad; Yang, Chenlu; Zhou, Yiming; Lin, Lei; Gonzalez-Rivas, Diego

    2017-01-01

    Interrupted IVC (also known as Azygos continuation of the inferior vena cava) is a relatively uncommon congenital condition with prevalence 1.5% (0.2–3%) of the general population (Bass et al.). Although it’s usually asymptomatic condition, splenic or cardiac abnormalities could be associated (Hardwick et al.). Incidental diagnosis during prenatal ultrasound screening or by routine imaging is the most common scenario. Special attention is required during right side thoracic procedures surgical resections in order to avoid scarifying the azygos vein that could lead to fatal results (Effler et al.). We herein report a video documented case of right upper lobectomy and mediastinal lymph node dissection for non-small cell carcinoma of lung in a patient who had interrupted hepatic segmental branch of the IVC. The procedure was performed via the subxiphoid uniportal VATS approach. PMID:29078654

  5. 40 CFR 1036.615 - Engines with Rankine cycle waste heat recovery and hybrid powertrains.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... vehicle wheels. These powertrains are tested using the hybrid engine test procedures of 40 CFR part 1065 or using the post-transmission test procedures in 40 CFR 1037.550. (2) Post-transmission hybrid... post-transmission hybrid powertrains: (1) Pre-transmission hybrid powertrains are those engine systems...

  6. Implantable intravascular defibrillator: defibrillation thresholds of an intravascular cardioverter-defibrillator compared with those of a conventional ICD in humans.

    PubMed

    Neuzil, Petr; Reddy, Vivek Y; Merkely, Bela; Geller, Laszlo; Molnar, Levente; Bednarek, Jacek; Bartus, Krzysztof; Richey, Mark; Bsee, T J Ransbury; Sanders, William E

    2014-02-01

    A percutaneous intravascular cardioverter-defibrillator (PICD) has been developed with a right ventricular (RV) single-coil lead and titanium electrodes in the superior vena cava (SVC)-brachiocephalic vein (BCV) region and the inferior vena cava (IVC). To compare defibrillation thresholds (DFTs) of the PICD with those of a conventional ICD in humans. Ten patients with ischemic cardiomyopathy and ejection fraction ≤35% were randomized to initial testing with either PICD or conventional ICD. A standard dual-coil lead was positioned in the RV apex. If randomized to PICD, the device was placed into the vasculature such that 1 titanium electrode was positioned in the SVC-BCV region and the second in the IVC. For PICD DFTs, the RV coil of the conventional ICD lead was connected to the PICD mandrel [shock vector: RV (+) to SVC-BCV (-) + IVC (-)]. When testing the conventional ICD, a subcutaneous pocket was formed in the left pectoralis region and the ICD was connected to the lead system and positioned in the pocket [shock vector: RV (+) to SVC (-) + active can (-)]. Each device was removed before testing with the other. A step-down binary search protocol determined the DFT, with the initial shock being 9 J. The mean PICD DFT was 7.6 ± 3.3 J, and the conventional ICD system demonstrated a mean DFT of 9.5 ± 4.7 J (N = 10; paired t test, P = .28). The intravascular defibrillator has DFTs similar to those of commercially available ICDs. Published by Heart Rhythm Society on behalf of Heart Rhythm Society.

  7. Anatomic variations of the renal vessels pertinent to transperitoneal vascular control in the management of trauma.

    PubMed

    Kaneko, Naoyuki; Kobayashi, Yasushi; Okada, Yoshiaki

    2008-05-01

    Operative exposure and control of the renal vessels through a transabdominal retroperitoneal (TARP) approach has been advocated for emergency management of renal trauma. The pertinent anatomic variations of the renal vasculature have not been well described. In 190 cadavers, the renal vessels were examined. The first 20 cadavers were examined via TARP approach, and 170 cadavers were investigated after evisceration. The findings were interpreted as they might relate to the TARP approach to the renal pedicle. The renal artery (RA) originated dorsally or inferiorly to the left renal vein (RV) in 70% of the cadavers on each side. Additional RAs emerging below the inferior mesenteric artery were present in 2.4% of cadavers on the right side and 1.8% on the left. Approach to the inferior vena cava (IVC) adequate for the management of trauma through the TARP approach was impossible, although it has been recommended in some research. The clinically significant incidence of variations was as follows: 47% multiple RAs, 13% multiple RVs, and 50% of at least 1 RA that coursed superior to the right RV on the right margin of the IVC. Knowledge of the varied anatomy of the renal vessels facilitates a safe approach to the kidneys in trauma management. The varied and unpredictable anatomy of the renal vasculature requires prompt change when the TARP approach fails to provide access to the vessels. In such cases, the colon should be mobilized promptly. On the right side of the IVC, the vessels are located so as to require clamping together almost always.

  8. A comparative CFD study of four inferior vena cava filters.

    PubMed

    López, Josep M; Fortuny, Gerard; Puigjaner, Dolors; Herrero, Joan; Marimon, Francesc

    2018-03-30

    Computational fluid dynamics was used to simulate the flow of blood within an inferior vena cava (IVC) geometry model that was reconstructed from computed tomography images obtained from a real patient. The main novelty of the present work is that we simulated the implantation of 4 different filter models in this realistic IVC geometry. We considered different blood flow rates in the range between V in =20 and V in =80 cm 3 /s, and all simulations were performed with both the Newtonian and a non-Newtonian model for the blood viscosity. We compared the hemodynamics performance of the different filter models, and we paid a special attention to the total drag force, F d , exerted by the blood flow on the filter surface. This force is the sum of 2 contributions: the viscous skin friction force, which was found to be roughly proportional to the filter surface area, and the pressure force, which depended on the particular filter geometry design. The F d force is relevant because it must be balanced by the total force exerted by the filter hooks/struts on the IVC wall at the attachment locations. For the highest V in value investigated, the variation in F d among filters was from 116 to 308 dyne. We also showed how the present results can be extrapolated to obtain good estimates of the drag forces if the blood viscosity levels change, ie, if the patient with a filter implanted is treated with anticoagulant therapy. Copyright © 2018 John Wiley & Sons, Ltd.

  9. Neutrophil extracellular traps promote deep vein thrombosis in mice

    PubMed Central

    Brill, A.; Fuchs, T.A.; Savchenko, A.S.; Thomas, G.M.; Martinod, K.; De Meyer, S.F.; Bhandari, A.A.; Wagner, D.D.

    2011-01-01

    Summary Background Upon activation, neutrophils can release nuclear material known as neutrophil extracellular traps (NETs), which were initially described as a part of antimicrobial defense. Extracellular chromatin was recently reported to be pro-thrombotic in vitro and to accumulate in plasma and thrombi of baboons with experimental deep vein thrombosis (DVT). Objective To explore the source and role of extracellular chromatin in DVT. Methods We used an established murine model of DVT induced by flow restriction (stenosis) in the inferior vena cava (IVC). Results We demonstrate that the levels of extracellular DNA increase in plasma after 6 h IVC stenosis, compared to sham-operated mice. Immunohistochemical staining revealed the presence of Gr-1-positive neutrophils in both red (RBC-rich) and white (platelet-rich) parts of thrombi. Citrullinated histone H3 (CitH3), an element of NETs’ structure, was present only in the red part of thrombi and was frequently associated with the Gr-1 antigen. Immunofluorescent staining of thrombi showed proximity of extracellular CitH3 and von Willebrand factor (VWF), a platelet adhesion molecule crucial for thrombus development in this model. Infusion of Deoxyribonuclease 1 (DNase 1) protected mice from DVT after 6 h and also 48 h IVC stenosis. Infusion of an unfractionated mixture of calf thymus histones increased plasma VWF and promoted DVT early after stenosis application. Conclusions Extracellular chromatin, likely originating from neutrophils, is a structural part of a venous thrombus and both the DNA scaffold and histones appear to contribute to the pathogenesis of DVT in mice. NETs may provide new targets for DVT drug development. PMID:22044575

  10. Collecting near mature and immature orchid seeds for ex situ conservation: 'in vitro collecting' as a case study.

    PubMed

    Kendon, Jonathan P; Rajaovelona, Landy; Sandford, Helen; Fang, Rui; Bell, Jake; Sarasan, Viswambharan

    2017-08-08

    Lack of phenological information and efficient collecting methods are considered impediments for orchid seed collecting. This leads to opportunistic collecting as part of general seed collecting schedules that may last few weeks especially in remote areas. The study explored the feasibility of collecting near mature and immature seeds to support conservation action plans. Mature, near mature and immature seeds of orchids were collected from the wild in the Central Highlands of Madagascar (CHM). Seed capsules were collected in sterile culture medium in the wild, to prevent deterioration of seeds inside the capsule after collecting, later to be cultured under laboratory conditions. Seed capsules collected by the in vitro collecting (IVC) method were kept in very good condition for up to 4 weeks before germination under in vitro conditions. Significantly faster and higher germination rate (p < 0.001) than mature seeds was observed in a number of taxa collected during a 3 year-long study. In some taxa even immature seeds, with no apparent sign of testa covering the embryo, germinated following IVC where mature seeds failed to germinate. We propose that IVC method has potential to complement conventional seed collecting by increasing the germplasm that can be used in integrated conservation action plans. Improvements can be made in developing collections for taxa from biodiversity hotspots and remote areas where collecting requires considerable resources. This method can further be used on a wider selection of plants from different geographic areas and on embryo rescue programmes for economically important plants.

  11. Contralateral Deep Vein Thrombosis after Iliac Vein Stent Placement in Patients with May-Thurner Syndrome.

    PubMed

    Le, Trong Binh; Lee, Taeg Ki; Park, Keun-Myoung; Jeon, Yong Sun; Hong, Kee Chun; Cho, Soon Gu

    2018-04-25

    To investigate the incidence and potential causes of contralateral deep vein thrombosis (DVT) after common iliac vein (CIV) stent placement in patients with May-Thurner syndrome (MTS). Data of 111 patients (women: 73%) who had CIV stent implantation for symptomatic MTS at a single center were retrospectively analyzed. Mean patient age was 63.1 ± 15.2 years. Median follow-up was 36 months (range, 1-142 months). Stent location was determined by venogram and classified as extended to the inferior vena cava (IVC), covered the confluence, or confined to the iliac vein. Potential causes of contralateral DVT were presumed based on venographic findings. The relationship between stent location and contralateral DVT was analyzed. Ten patients (9%, men/women: 4/6) exhibited contralateral DVT at a median timing of 40 months (range, 6-98 months). Median age was 69 years (range, 42-85 years). Median follow-up was 73.5 months (range, 20-134 months). Potential causes were venous intimal hyperplasia (VIH) (n = 7), "jailing" (n = 2), and indeterminate (n = 1). All patients with VIH had previous CIV stents overextended to the IVC. Overextension of CIV stent was associated with contralateral DVT (P < .001). The primary patency rate of the contralateral CIV stent was 70% at 20 months. Contralateral DVT after CIV stent implantation has a relatively high incidence and often occurs late during follow-up. Overextension of the CIV stent to the IVC is associated with development of contralateral DVT, and VIH should be considered a potential cause. Copyright © 2018 SIR. Published by Elsevier Inc. All rights reserved.

  12. Effects of sorbitol on porcine oocyte maturation and embryo development in vitro.

    PubMed

    Lin, Tao; Zhang, Jin Yu; Diao, Yun Fei; Kang, Jung Won; Jin, Dong-Il

    2015-04-01

    In the present study, a porcine system was supplemented with sorbitol during in vitro maturation (IVM) or in vitro culture (IVC), and the effects of sorbitol on oocyte maturation and embryonic development following parthenogenetic activation were assessed. Porcine immature oocytes were treated with different concentrations of sorbitol during IVM, and the resultant metaphase II stage oocytes were activated and cultured in porcine zygote medium-3 (PZM-3) for 7 days. No significant difference was observed in cumulus expansion and the nuclear maturation between the control and sorbitol-treated groups, with the exception of the 100 mM group, which showed significantly decreased nuclear maturation and cumulus expansion. There was no significant difference in the intracellular reactive oxygen species (ROS) levels between oocytes matured with 10 or 20 mM sorbitol and control groups, but 50 and 100 mM groups had significantly higher ROS levels than other groups. The 20 mM group showed significant increases in intracellular glutathione and subsequent blastocyst formation rates following parthenogenetic activation compared with the other groups. During IVC, supplementation with sorbitol significantly reduced blastocyst formation and increased the apoptotic index compared with the control. The apoptotic index of blastocysts from the sorbitol-treated group for entire culture period was significantly higher than those of the partially sorbitol-exposed groups. Based on these findings, it can be concluded that the addition of a low concentration of sorbitol (20 mM) during IVM of porcine oocytes benefits subsequent blastocyst development and improves embryo quality, whereas sorbitol supplement during IVC has a negative effect on blastocyst formation.

  13. Staphylococcus xylosus PCR-validated Decontamination of Murine Individually Ventilated Cage Racks and Air Handling Units by Using 'Active-Closed' Exposure to Vaporized Hydrogen Peroxide.

    PubMed

    Ragland, Natalie H; Miedel, Emily L; Gomez, Jose M; Engelman, Robert W

    2017-11-01

    Vaporized hydrogen peroxide (VHP) is used to decontaminate clinical, biocontainment, and research animal rooms and equipment. To assist with its implementation in a murine facility, we developed a safe and effective method of VHP sterilization of IVC racks and air handling units (AHU). Safety of VHP decontamination was assessed by ensuring VHP levels dissipated to less than 1 ppm in the room prior to personnel reentry and inside the primary enclosure prior to the return of mice; this condition occurred at least 18 h after the VHP cycle. Efficacy of VHP sterilization was assessed by using chemical indicators, biologic indicators, and PCR testing for Staphylococcus xylosus, a commensal organism of murine skin and an opportunistic pathogen, which was present in 160 of 172 (93%) of specimens from occupied IVC racks and the interior surfaces of in-use AHU. Neither mechanized washing nor hand-sanitizing eradicated S. xylosus from equipment airway interiors, with 17% to 24% of specimens remaining PCR-positive for S. xylosus. 'Static-open' VHP exposure of sanitized equipment did not ensure its sterilization. In contrast, 'active-closed' VHP exposure, in which IVC racks were assembled, sealed, and connected to AHU set to the VHP cycle, increased the proportion of chemical indicators that detected sterilizing levels of VHP inside the assembled equipment, and significantly decreased PCR-detectable S. xylosus inside the equipment. Supplementing bulk steam sterilization of the primary enclosure with VHP sterilization of the secondary housing equipment during room change-outs may help to mitigate opportunistic agents that jeopardize studies involving immunodeficient strains.

  14. Analysis of the Final DENALI Trial Data: A Prospective, Multicenter Study of the Denali Inferior Vena Cava Filter.

    PubMed

    Stavropoulos, S William; Chen, James X; Sing, Ronald F; Elmasri, Fakhir; Silver, Mitchell J; Powell, Alex; Lynch, Frank C; Abdel Aal, Ahmed Kamel; Lansky, Alexandra; Muhs, Bart E

    2016-10-01

    To report the final 2-year data on the efficacy and safety of a nitinol retrievable inferior vena cava (IVC) filter for protection against pulmonary embolism (PE). This was a prospective multicenter trial of 200 patients with temporary indications for caval filtration who underwent implantation of the Denali IVC filter. After filter placement, all patients were followed for 2 years after placement or 30 days after filter retrieval. The primary endpoints were technical success of filter implantation in the intended location and clinical success of filter placement and retrieval. Secondary endpoints were incidence of clinically symptomatic recurrent PE, new or propagating deep vein thrombosis (DVT), and filter-related complications including migration, fracture, penetration, and tilt. Filter placement was technically successful in 199 patients (99.5%). Filters were clinically successful in 190 patients (95%). The rate of PE was 3% (n = 6), with 5 patients having a small subsegmental PE and 1 having a lobar PE. New or worsening DVT was noted in 26 patients (13%). Filter retrieval was attempted 125 times in 124 patients and was technically successful in 121 patients (97.6%). The mean filter dwell time at retrieval was 200.8 days (range, 5-736 d). There were no instances of filter fracture, migration, or tilt greater than 15° at the time of filter retrieval or during follow-up. The Denali IVC filter exhibited high success rates for filter placement and retrieval while maintaining a low complication rate in this clinical trial. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  15. An Empirical Study of Inter-Vehicle Communication Performance Using NS-2

    DOT National Transportation Integrated Search

    2010-08-01

    In recent years, there has been increasing interest in inter-vehicle communications (IVC) based on wireless networks to collect and distribute traffic information in various Intelligent Transportation Systems applications. In this paper, we study the...

  16. Cysteamine supplementation during in vitro maturation of slaughterhouse- and opu-derived bovine oocytes improves embryonic development without affecting cryotolerance, pregnancy rate, and calf characteristics.

    PubMed

    Merton, J S; Knijn, H M; Flapper, H; Dotinga, F; Roelen, B A J; Vos, P L A M; Mullaart, E

    2013-09-01

    Optimization of ovum pick up (OPU) followed by in vitro embryo production (IVP) is strongly driven by the needs of both beef and dairy cattle breeders to enhance genetic improvement. The rapidly growing use of genomic selection in cattle has increased the interest in using OPU-IVP technology to increase the number of embryos and offspring per donor, thus allowing enhanced selection intensity for the next generation. The aim of this study was to optimize embryo production through supplementation of cysteamine during in vitro maturation (IVM) and in vitro culture (IVC) of both slaughterhouse- and OPU-derived oocytes. The effects on embryo production and on embryo cryotolerance, post-transfer embryo survival, and calf characteristics, including gestation length, birth weight, perinatal mortality, and sex ratio were studied. In study 1, immature slaughterhouse-derived cumulus-oocyte complexes (COCs) were matured in IVM medium supplemented with or without 0.1 mM cysteamine, fertilized and cultured for 7 days in 0.5 ml SOFaaBSA. In study 2, cysteamine was present during both IVM (0.1 mM) and IVC (0.01, 0.05, 0.1 mM) from Days 1 to 4. In study 3, OPU-derived COCs were matured in medium supplemented with or without 0.1 mM cysteamine in a 2 × 2 factorial design (OPU week and cysteamine treatment). Embryos were evaluated for stage and grade on Day 7 and, depending on the number of transferable embryos and recipients available, the embryos were transferred either fresh or frozen-thawed at a later date. The presence of cysteamine during IVM significantly increased the embryo production rate with slaughterhouse-derived COCs (24.0% vs. 19.4%). The higher number of embryos at Day 7 was due to an increased number of blastocysts, whereas the distribution of embryos among different quality grades and cryotolerance was not affected. Embryo production rate was negatively affected when cysteamine was present during both the processes of IVM and IVC during Days 1 to 4 of culture (13.2%-19.3% vs. 26.4%). The presence of cysteamine during IVM of OPU-derived COCs also significantly increased the embryo production rate (34.4% vs. 23.4%). The higher number of embryos was again totally due to an increased number of blastocysts, whereas cryotolerance was not affected. The relative increase in embryo production rate was higher with OPU-derived oocytes compared with slaughterhouse-derived COCs (47% vs. 24%). This improvement resulted in a mean of 1.73 transferable embryos per OPU session compared with 1.06 in the absence of cysteamine. The presence of cysteamine did not affect pregnancy rate, gestation length, birth weight, perinatal mortality, and sex of calves born from either fresh or frozen-thawed embryos. This study reported that cysteamine supplementation during IVM greatly improved the efficiency and affectivity of an OPU-IVP program. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. 40 CFR 1036.615 - Engines with Rankine cycle waste heat recovery and hybrid powertrains.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 1065 or with the post-transmission test procedures in 40 CFR 1037.550. Pre-transmission hybrid... post-transmission hybrid powertrains: (1) Pre-transmission hybrid powertrains are those engine systems... or using the post-transmission test procedures in 40 CFR 1037.550. (2) Post-transmission hybrid...

  18. Our Energy Options.

    ERIC Educational Resources Information Center

    Meyers, Paul A.; Witt, Frank C.

    Presented is an analysis of alternatives available to the United States in dealing with energy problems. Options explained and evaluated include coal, solar, hydroelectric, nuclear, geothermal, wind, biomass, and energy conservation. The booklet is part of Project APEC (America's Possible Energy Choices), a nationally validated Title IVc project…

  19. Veno-venous extracorporeal membrane oxygenation using a double-lumen bi-caval cannula for severe respiratory failure post total artificial heart implantation.

    PubMed

    Miessau, J; Yang, Q; Unai, S; Entwistle, J W C; Cavarocchi, N C; Hirose, H

    2015-07-01

    We report a unique utilization of a double-lumen, bi-caval Avalon cannula for veno-venous (VV) extracorporeal membrane oxygenation (ECMO) during placement of a total artificial heart (TAH, SynCardia, Tucson, AZ). A 22-year-old female with post-partum cardiomyopathy was rescued on veno-arterial (VA) ECMO because of cardiogenic shock. The inability to wean ECMO necessitated implantation of the TAH as a bridge to transplant. In addition, the patient continued to have respiratory failure and concomitant VV ECMO was planned with the implant. During TAH implantation, the Avalon cannula was placed percutaneously from the right internal jugular vein into the inferior vena cava (IVC) under direct vision while the right atrium was open. During VV ECMO support, adequate flows on both ECMO and TAH were maintained without adverse events. VV ECMO was discontinued, without reopening the chest, once the patient's respiratory failure improved. However, the patient subsequently developed a profound respiratory acidosis and required VV ECMO for CO2 removal. The Avalon cannula was placed in the femoral vein to avoid accessing the internal jugular vein and risking damage to the TAH. The patient's oxygenation eventually improved and the cannula was removed at the bedside. The patient was supported for 22 days on VV ECMO and successfully weaned from the ventilator prior to her orthotropic heart transplantation. © The Author(s) 2014.

  20. Emergency pancreatoduodenectomy for complex injuries of the pancreas and duodenum

    PubMed Central

    Krige, Jake E; Nicol, Andrew J; Navsaria, Pradeep H

    2014-01-01

    Background This single-centre study evaluated the outcome of a pancreatoduodenectomy for Grade 5 injuries of the pancreas and duodenum. Methods Prospectively recorded data of patients who underwent a pancreatoduodenectomy for trauma at a Level I Trauma Centre during a 22-year period were analysed. Results Nineteen (17 men and 2 women, median age 28 years, range 14–53 years) out of 426 patients with pancreatic injuries underwent a pancreatoduodenectomy (gunshot n = 12, blunt trauma n = 6 and stab wound n = 1). Nine patients had associated inferior vena cava (IVC) or portal vein (PV) injuries. Five patients had initial damage control procedures and underwent a definitive operation at a median of 15 h (range 11–92) later. Twelve had a pylorus-preserving pancreatoduodenectomy (PPPD) and 7 a standard Whipple. Three patients with APACHE II scores of 15, 18, 18 died post-operatively of multi-organ failure. All 16 survivors had Dindo-Clavien grade I (n = 1), grade II (n = 7), grade IIIa (n = 2), grade IVa (n = 6) post-operative complications. Factors complicating surgery were shock on admission, number of associated injuries, coagulopathy, hypothermia, gross bowel oedema and traumatic pancreatitis. Conclusions A pancreatoduodenectomy is a life-saving procedure in a small cohort of stable patients with non-reconstructable pancreatic head injuries. Damage control before a pancreatoduodenectomy will salvage a proportion of the most severely injured patients who have multiple injuries. PMID:24841125

  1. Emergency pancreatoduodenectomy for complex injuries of the pancreas and duodenum.

    PubMed

    Krige, Jake E; Nicol, Andrew J; Navsaria, Pradeep H

    2014-11-01

    This single-centre study evaluated the outcome of a pancreatoduodenectomy for Grade 5 injuries of the pancreas and duodenum. Prospectively recorded data of patients who underwent a pancreatoduodenectomy for trauma at a Level I Trauma Centre during a 22-year period were analysed. Nineteen (17 men and 2 women, median age 28 years, range 14-53 years) out of 426 patients with pancreatic injuries underwent a pancreatoduodenectomy (gunshot n = 12, blunt trauma n = 6 and stab wound n = 1). Nine patients had associated inferior vena cava (IVC) or portal vein (PV) injuries. Five patients had initial damage control procedures and underwent a definitive operation at a median of 15 h (range 11-92) later. Twelve had a pylorus-preserving pancreatoduodenectomy (PPPD) and 7 a standard Whipple. Three patients with APACHE II scores of 15, 18, 18 died post-operatively of multi-organ failure. All 16 survivors had Dindo-Clavien grade I (n = 1), grade II (n = 7), grade IIIa (n = 2), grade IVa (n = 6) post-operative complications. Factors complicating surgery were shock on admission, number of associated injuries, coagulopathy, hypothermia, gross bowel oedema and traumatic pancreatitis. A pancreatoduodenectomy is a life-saving procedure in a small cohort of stable patients with non-reconstructable pancreatic head injuries. Damage control before a pancreatoduodenectomy will salvage a proportion of the most severely injured patients who have multiple injuries. © 2014 International Hepato-Pancreato-Biliary Association.

  2. PCR Testing of IVC Filter Tops as a Method for Detecting Murine Pinworms and Fur Mites.

    PubMed

    Gerwin, Philip M; Ricart Arbona, Rodolfo J; Riedel, Elyn R; Henderson, Kenneth S; Lipman, Neil S

    2017-11-01

    We evaluated PCR testing of filter tops from cages maintained on an IVC system through which exhaust air is filtered at the cage level as a method for detecting parasite-infected and -infested cages. Cages containing 4 naïve Swiss Webster mice received 360 mL of uncontaminated aspen chip or α-cellulose bedding (n = 18 cages each) and 60 mL of the same type of bedding weekly from each of the following 4 groups of cages housing mice infected or infested with Syphacia obvelata (SO), Aspiculuris tetraptera (AT), Myocoptes musculinus (MC), or Myobia musculi (MB) and Radfordia affinis (RA; 240 mL bedding total). Detection rates were compared at 30, 60, and 90 d after initiating bedding exposure, by using PCR analysis of filter tops (media extract and swabs) and testing of mouse samples (fur swab [direct] PCR testing, fecal flotation, anal tape test, direct examination of intestinal contents, and skin scrape). PCR testing of filter media extract detected 100% of all parasites at 30 d (both bedding types) except for AT (α-cellulose bedding, 67% detection rate); identified more cages with fur mites (MB and MC) than direct PCR when cellulose bedding was used; and was better at detecting parasites than all nonmolecular methods evaluated. PCR analysis of filter media extract was superior to swab and direct PCR for all parasites cumulatively for each bedding type. Direct PCR more effectively detected MC and all parasites combined for aspen chip compared with cellulose bedding. PCR analysis of filter media extract for IVC systems in which exhaust air is filtered at the cage level was shown to be a highly effective environmental testing method.

  3. Outcomes and Direct Costs of Inferior Vena Cava Filter Placement and Retrieval within the IR and Surgical Settings.

    PubMed

    Makary, Mina S; Kapke, Jordan; Yildiz, Vedat; Pan, Xueliang; Dowell, Joshua D

    2018-02-01

    To compare the outcomes and costs of inferior vena cava (IVC) filter placement and retrieval in the interventional radiology (IR) and surgical departments at a tertiary-care center. Retrospective review was performed of 142 sequential outpatient IVC filter placements and 244 retrievals performed in the IR suite and operating room (OR) from 2013 to 2016. Patient demographic data, procedural characteristics, outcomes, and direct costs were compared between cohorts. Technical success rates of 100% were achieved for both IR and OR filter placements, and 98% of filters were successfully retrieved by IR means, compared with 83% in the OR (P < .01). Fluoroscopy time was similar for IR and OR filter insertions, but IR retrievals required half the fluoroscopy time, with an average of 9 minutes vs 18 minutes in the OR (P = .02). There was no significant difference between cohorts in the incidences of complications for filter retrievals, but more postprocedural complications were observed for OR placements (8%) vs IR placements (1%; P = .05). The most severe complication occurred during an OR filter retrieval, resulting in entanglement of the snare device and conversion to an emergent open filter removal by vascular surgery. Direct costs were approximately 20% higher for OR vs IR IVC filter placements ($2,246 vs $2,671; P = .01). Filter placements are equally successfully performed in IR and OR settings, but OR patients experienced significantly higher postprocedural complication rates and incurred higher costs. In contrast, higher technical success rates and shorter fluoroscopy times were observed for IR filter retrievals compared with those performed in the OR. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  4. Simulation-Based Laparoscopic Surgery Crisis Resource Management Training-Predicting Technical and Nontechnical Skills.

    PubMed

    Goldenberg, Mitchell G; Fok, Kai H; Ordon, Michael; Pace, Kenneth T; Lee, Jason Y

    2017-12-19

    To develop a unique simulation-based assessment using a laparoscopic inferior vena cava (IVC) injury scenario that allows for the safe assessment of urology resident's technical and nontechnical skills, and investigate the effect of personality traits performance in a surgical crisis. Urology residents from our institution were recruited to participate in a simulation-based training laparoscopic nephrectomy exercise. Residents completed demographic and multidimensional personality questionnaires and were instructed to play the role of staff urologist. A vasovagal response to pneumoperitoneum and an IVC injury event were scripted into the scenario. Technical and nontechnical skills were assessed by expert laparoscopic surgeons using validated tools (task checklist, GOALS, and NOTSS). Ten junior and five senior urology residents participated. Five residents were unable to complete the exercise safely. Senior residents outperformed juniors on technical (checklist score 15.1 vs 9.9, p < 0.01, GOALS score 18.0 vs 13.3, p < 0.01) and nontechnical performance (NOTSS score 13.8 vs 10.1, p = 0.03). Technical performance scores correlated with NOTSS scores (p < 0.01) and pass/fail rating correlated with technical performance (p < 0.01 for both checklist and GOALS), NOTSS score (p = 0.02), and blood loss (p < 0.01). Only the conscientiousness dimension of the big five inventory correlated with technical score (p = 0.03) and pass/fail rating (p = 0.04). Resident level of training and laparoscopic experience correlated with technical performance during a simulation-based laparoscopic IVC injury crisis management scenario, as well as multiple domains of nontechnical performance. Personality traits of our surgical residents are similar and did not predict technical skill. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  5. The Influence of the Photoionizing Radiation Spectrum on Metal-Line Ratios in Ly(alpha) Forest Clouds

    NASA Technical Reports Server (NTRS)

    Giroux, Mark L.; Shull, J. Michael

    1997-01-01

    Recent measurements of Si IV/C IV ratios in the high-redshift Ly(alpha) forest (Songaila & Cowie, AJ, 112, 335 (1996a); Savaglio et at., A&A (in press) (1997)) have opened a new window on chemical enrichment and the first generations of stars. However, the derivation of accurate Si/C abundances requires reliable ionization corrections, which are strongly dependent on the spectral shape of the metagalactic ionizing background and on the 'local effects' of hot stars in nearby galaxies. Recent models have assumed power-law quasar ionizing backgrounds plus a decrement at 4 Ryd to account for He II attenuation in intervening clouds. However, we show that realistic ionizing backgrounds based on cosmological radiative transfer models produce more complex ionizing spectra between 1-5 Ryd that are critical to interpreting ions of Si and C. We also make a preliminary investigation of the effects of He II ionization front nonoverlap. Because the attenuation and reemission by intervening clouds enhance Si IV relative to C the observed high Si IV/C IV ratios do not require an unrealistic Si overproduction (Si/C greater than or equal to 3 (Si/C)(solar mass)). If the ionizing spectrum is dominated by 'local effects' from massive stars, even larger Si IV/C IV ratios are possible. However, unless stellar radiation dominates quasars by more than a factor of 10, we confirm the evidence for some Si overproduction by massive stars; values Si/C approx. 2(Si/C)(solar mass) fit the measurements better than solar abundances. Ultimately, an adequate interpretation of the ratios of C IV, Si IV, and C II may require hot, collisionally ionized gas in a multiphase medium.

  6. The effect of two different Individually Ventilated Cage systems on anxiety-related behaviour and welfare in two strains of laboratory mouse.

    PubMed

    Burman, O; Buccarello, L; Redaelli, V; Cervo, L

    2014-01-30

    The environment in which a laboratory animal is housed can significantly influence its behaviour and welfare, acting as a potential confounding factor for those studies in which it is utilised. This study investigated the impact of two Individually Ventilated Cage (IVC) housing systems on anxiety-related behaviour and welfare indicators in two common strains of laboratory mice. Subjects were juvenile female C57BL/6J and BALB/c mice (N=128) housed in groups of four in two different IVC systems for 7weeks. System One had air delivery at the cage 'cover' level at 75 ACH (Air Changes/Hour) and System Two had air delivery at the 'animal' level at 50 ACH. Mice were assessed twice a week (e.g. bodyweight) or at the end of the study (e.g. anxiety tests). Our results showed significant differences in anxiety-related behaviour between strains and housing systems. Mice in System Two, regardless of strain, defecated more in the Elevated Plus Maze (EPM), spent less time in the open arms of the EPM, and less time in the central zone of the Open Field (OF). Strain differences in anxiety-like behaviour were seen in the increased defecation by BALB/c mice in the OF and EPM and less time spent in the open arms of the EPM compared to C57BL/6J mice. These results suggest that different IVC housing systems can influence mouse behaviour in different ways, with mice of both strains studied exhibiting more anxiety-related behaviour when housed in System Two (air entry at the 'animal' level at 50 ACH), which could impact upon experimental data. © 2013. Published by Elsevier Inc. All rights reserved.

  7. The utility of CT for predicting bile leaks in hepatic trauma.

    PubMed

    LeBedis, Christina A; Anderson, Stephan W; Mercier, Gustavo; Kussman, Steven; Coleman, Stephanie L; Golden, Louis; Penn, David R; Uyeda, Jennifer W; Soto, Jorge A

    2015-04-01

    The purpose of this study was to determine the efficacy of CT to predict the development of bile leaks in hepatic trauma. This HIPAA-compliant retrospective study was IRB approved and consent was waived. All patients who sustained hepatic trauma between January 1, 2006, and January 31, 2012, and who underwent CT and hepatobiliary scans during the same hospital admission were included. One hundred and thirty-two patients met the inclusion criteria. Comparison between the presence of biliary injury relative to American Association for the Surgery of Trauma (AAST) hepatic injury grade and mean distance of the hepatic laceration to the inferior vena cava (IVC) was made. The ability of free fluid to predict bile injury was analyzed. Forty-one (31 %) of the 132 patients had positive hepatobiliary scans. Of these 41 patients, seven (17 %) sustained low-grade and 34 (83 %) sustained high-grade hepatic injury compared with the 37 (41 %) low-grade and 54 (59 %) high-grade hepatic injuries in the negative hepatobiliary scan group. The mean distance to the IVC was 2.4 cm (SD 2.9 cm) and 3.6 cm (SD 3.3 cm) in patients with and without bile leaks, respectively. A statistically significant difference in the proportion of high-grade injuries and the mean distance from the IVC between the two groups was identified. The presence of free fluid on CT is sensitive, but not specific, for detecting a bile leak. CT findings, including AAST liver injury grade and location of the liver laceration, are able to predict which patients are at risk for developing bile leaks as seen on hepatobiliary scintigraphy, whereas the presence of free fluid is not.

  8. Sinus venosus syndrome: atrial septal defect or anomalous venous connection? A multiplane transoesophageal approach.

    PubMed

    Oliver, J M; Gallego, P; Gonzalez, A; Dominguez, F J; Aroca, A; Mesa, J M

    2002-12-01

    To discuss the anatomical features of sinus venosus atrial defect on the basis of a comprehensive transoesophageal echocardiography (TOE) examination and its relation to surgical data. 24 patients (13 men, 11 women, mean (SD) age 37 (17) years, range 17-73 years) with a posterior interatrial communication closely related to the entrance of the superior (SVC) or inferior vena cava (IVC) who underwent TOE before surgical repair. Records of these patients were retrospectively reviewed and compared with surgical assessments. In 13 patients, TOE showed a deficiency in the extraseptal wall that normally separates the left atrium and right upper pulmonary vein from the SVC and right atrium. This deficiency unroofed the right upper pulmonary vein, compelling it to drain into the SVC, which overrode the intact atrial septum. In three patients, TOE examination showed a defect in the wall of the IVC, which continued directly into the posterior border of the left atrium. Thus, the intact muscular border of the atrial septum was overridden by the mouth of the IVC, which presented a biatrial connection. In the remaining eight patients, the defect was located in the muscular posterior border of the fossa ovalis. A residuum of atrial septum was visualised in the superior margin of the defect. Neither caval vein overriding nor anomalous pulmonary vein drainage was present. Sinus venosus syndrome should be regarded as an anomalous venous connection with an interatrial communication outside the confines of the atrial septum, in the unfolding wall that normally separates the left atrium from either caval vein. It results in overriding of the caval veins across the intact atrial septum and partial pulmonary vein anomalous drainage. It should be differentiated from posterior atrial septal defect without overriding or anomalous venous connections.

  9. Sinus venosus syndrome: atrial septal defect or anomalous venous connection? A multiplane transoesophageal approach

    PubMed Central

    Oliver, J M; Gallego, P; Gonzalez, A; Dominguez, F J; Aroca, A; Mesa, J M

    2002-01-01

    Objective: To discuss the anatomical features of sinus venosus atrial defect on the basis of a comprehensive transoesophageal echocardiography (TOE) examination and its relation to surgical data. Methods: 24 patients (13 men, 11 women, mean (SD) age 37 (17) years, range 17–73 years) with a posterior interatrial communication closely related to the entrance of the superior (SVC) or inferior vena cava (IVC) who underwent TOE before surgical repair. Records of these patients were retrospectively reviewed and compared with surgical assessments. Results: In 13 patients, TOE showed a deficiency in the extraseptal wall that normally separates the left atrium and right upper pulmonary vein from the SVC and right atrium. This deficiency unroofed the right upper pulmonary vein, compelling it to drain into the SVC, which overrode the intact atrial septum. In three patients, TOE examination showed a defect in the wall of the IVC, which continued directly into the posterior border of the left atrium. Thus, the intact muscular border of the atrial septum was overridden by the mouth of the IVC, which presented a biatrial connection. In the remaining eight patients, the defect was located in the muscular posterior border of the fossa ovalis. A residuum of atrial septum was visualised in the superior margin of the defect. Neither caval vein overriding nor anomalous pulmonary vein drainage was present. Conclusions: Sinus venosus syndrome should be regarded as an anomalous venous connection with an interatrial communication outside the confines of the atrial septum, in the unfolding wall that normally separates the left atrium from either caval vein. It results in overriding of the caval veins across the intact atrial septum and partial pulmonary vein anomalous drainage. It should be differentiated from posterior atrial septal defect without overriding or anomalous venous connections. PMID:12433899

  10. PCR Testing of IVC Filter Tops as a Method for Detecting Murine Pinworms and Fur Mites

    PubMed Central

    Gerwin, Philip M; Arbona, Rodolfo J Ricart; Riedel, Elyn R; Henderson, Kenneth S; Lipman, Neil S

    2017-01-01

    We evaluated PCR testing of filter tops from cages maintained on an IVC system through which exhaust air is filtered at the cage level as a method for detecting parasite- infected and -infested cages. Cages containing 4 naïve Swiss Webster mice received 360 mL of uncontaminated aspen chip or α-cellulose bedding (n = 18 cages each) and 60 mL of the same type of bedding weekly from each of the following 4 groups of cages housing mice infected or infested with Syphacia obvelata (SO), Aspiculuris tetraptera (AT), Myocoptes musculinus (MC), or Myobia musculi (MB) and Radfordia affinis (RA; 240 mL bedding total). Detection rates were compared at 30, 60, and 90 d after initiating bedding exposure, by using PCR analysis of filter tops (media extract and swabs) and testing of mouse samples (fur swab [direct] PCR testing, fecal flotation, anal tape test, direct examination of intestinal contents, and skin scrape). PCR testing of filter media extract detected 100% of all parasites at 30 d (both bedding types) except for AT (α-cellulose bedding, 67% detection rate); identified more cages with fur mites (MB and MC) than direct PCR when cellulose bedding was used; and was better at detecting parasites than all nonmolecular methods evaluated. PCR analysis of filter media extract was superior to swab and direct PCR for all parasites cumulatively for each bedding type. Direct PCR more effectively detected MC and all parasites combined for aspen chip compared with cellulose bedding. PCR analysis of filter media extract for IVC systems in which exhaust air is filtered at the cage level was shown to be a highly effective environmental testing method. PMID:29256370

  11. Lung volumes during sustained microgravity on Spacelab SLS-1

    NASA Technical Reports Server (NTRS)

    Elliott, Ann R.; Prisk, G. Kim; Guy, Harold J. B.; West, John B.

    1994-01-01

    Gravity is known to influence the mechanical behavior of the lung and chest wall. However, the effect of sustained microgravity (microgravity) on lung volumes has not been reported. Pulmonary function tests were performed by four subjects before, during, and after 9 days of microgravity exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box-and-flowmeter system and a respiratory mass spectrometer. Measurements included functional residual capacity (FRC), expiratory reserve volume (ERV), residual volume (RV), inspiratory and expiratory vital capacities (IVC and EVC), and tidal volume (V9sub T)). Total lung capacity (TLC) was derived from the measured EVC and RV values. With preflight standing values as a comparison, FRC was significantly reduced by 15% (approximately 500 ml) in microgravity and 32% in the supine posture. ERV was reduced by 10 - 20% in microgravity and decreased by 64% in the supine posture. RV was significantly reduced by 18% (310 ml) in microgravity but did not significantly change in the supine posture compared with standing. IVC and EVC were slightly reduced during the first 24 h of microgravity but returned to 1-G standing values within 72 h of microgravity exposure. IVC and EVC in the supine posture were significantly reduced by 12% compared with standing. During microgravity, V(sub T) decreased by 15% (approximately 90 ml), but supine V(sub T) was unchanged compared with preflight standing values. TLC decreased by approximately 8% during microgravity and in the supine posture compared with preflight standing. The reductions in FRC, ERV, and RV during microgravity are probably due to the cranial shift of the diaphragm, an increase in intrathoracic blood volume, and more uniform alveolar expansion.

  12. Staphylococcus xylosus PCR-validated Decontamination of Murine Individually Ventilated Cage Racks and Air Handling Units by Using ‘Active–Closed’ Exposure to Vaporized Hydrogen Peroxide

    PubMed Central

    Ragland, Natalie H; Miedel, Emily L; Gomez, Jose M; Engelman, Robert W

    2017-01-01

    Vaporized hydrogen peroxide (VHP) is used to decontaminate clinical, biocontainment, and research animal rooms and equipment. To assist with its implementation in a murine facility, we developed a safe and effective method of VHP sterilization of IVC racks and air handling units (AHU). Safety of VHP decontamination was assessed by ensuring VHP levels dissipated to less than 1 ppm in the room prior to personnel reentry and inside the primary enclosure prior to the return of mice; this condition occurred at least 18 h after the VHP cycle. Efficacy of VHP sterilization was assessed by using chemical indicators, biologic indicators, and PCR testing for Staphylococcus xylosus, a commensal organism of murine skin and an opportunistic pathogen, which was present in 160 of 172 (93%) of specimens from occupied IVC racks and the interior surfaces of in-use AHU. Neither mechanized washing nor hand-sanitizing eradicated S. xylosus from equipment airway interiors, with 17% to 24% of specimens remaining PCR-positive for S. xylosus. ‘Static–open’ VHP exposure of sanitized equipment did not ensure its sterilization. In contrast, ‘active–closed’ VHP exposure, in which IVC racks were assembled, sealed, and connected to AHU set to the VHP cycle, increased the proportion of chemical indicators that detected sterilizing levels of VHP inside the assembled equipment, and significantly decreased PCR-detectable S. xylosus inside the equipment. Supplementing bulk steam sterilization of the primary enclosure with VHP sterilization of the secondary housing equipment during room change-outs may help to mitigate opportunistic agents that jeopardize studies involving immunodeficient strains. PMID:29256369

  13. Management of inferior vena cava aneurysm.

    PubMed

    Montero-Baker, M F; Branco, B C; Leon, L L; Labropoulos, N; Echeverria, A; Mills, J L

    2015-10-01

    Inferior vena cava (IVC) aneurysm is an infrequent but potentially lethal abnormality. We have seen one such case in our group practice. We have added this case to a review of 53 previously reported cases in order to develop a management algorithm for this entity. We conducted a MedLine search of all English-language articles from the first reported case in 1950 through August 2013. Patient demographics, clinical data, management and outcomes were extracted. IVC aneurysms were categorized in 4 types as per Gradman and Steinberg classification. The mean patient age was 27.1 years (range 5-89) and 57.4% were male. A total of 11 (20.3%) had associated vascular anomalies and iliocaval thrombosis was found in 10 (18.5%). There were 23 type I aneurysms, 8 type IIs, 21 type IIIs and 2 type IVs. All but 1 type I was successfully managed conservatively without complications. For type IIs, only 3 patients were managed conservatively with 1 death related to stroke from paradoxical embolus. For type IIIs, resection was the most common management option (14 patients). One patient was treated endovascularly with aneurysm embolization. A total of 6 asymptomatic patients were treated conservatively with 1 death due to thromboembolism. For type IVs, all cases underwent expectant management with 1 death due to aneurysm rupture. IVC aneurysms are rare with only 54 cases reported in the literature. Associated vascular anomalies and iliocaval thrombosis should be expected in approximately 20% of cases. Type I aneurysms can be managed expectantly with close surveillance unless symptomatic. For type II-IV, surgical consideration should be given based on high rates of thromboembolic complications and non-negligible risk of rupture.

  14. Lung volumes during sustained microgravity on Spacelab SLS-1.

    PubMed

    Elliott, A R; Prisk, G K; Guy, H J; West, J B

    1994-10-01

    Gravity is known to influence the mechanical behavior of the lung and chest wall. However, the effect of sustained microgravity (mu G) on lung volumes has not been reported. Pulmonary function tests were performed by four subjects before, during, and after 9 days of mu G exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box-and-flowmeter system and a respiratory mass spectrometer. Measurements included functional residual capacity (FRC), expiratory reserve volume (ERV), residual volume (RV), inspiratory and expiratory vital capacities (IVC and EVC), and tidal volume (VT). Total lung capacity (TLC) was derived from the measured EVC and RV values. With preflight standing values as a comparison, FRC was significantly reduced by 15% (approximately 500 ml) in mu G and 32% in the supine posture. ERV was reduced by 10-20% in mu G and decreased by 64% in the supine posture. RV was significantly reduced by 18% (310 ml) in mu G but did not significantly change in the supine posture compared with standing. IVC and EVC were slightly reduced during the first 24 h of mu G but returned to 1-G standing values within 72 h of mu G exposure. IVC and EVC in the supine posture were significantly reduced by 12% compared with standing. During mu G, VT decreased by 15% (approximately 90 ml), but supine VT was unchanged compared with preflight standing values. TLC decreased by approximately 8% during mu G and in the supine posture compared with preflight standing. The reductions in FRC, ERV, and RV during mu G are probably due to the cranial shift of the diaphragm, an increase in intrathoracic blood volume, and more uniform alveolar expansion.

  15. The DENALI Trial: an interim analysis of a prospective, multicenter study of the Denali retrievable inferior vena cava filter.

    PubMed

    Stavropoulos, S William; Sing, Ronald F; Elmasri, Fakhir; Silver, Mitchell J; Powell, Alex; Lynch, Frank C; Aal, Ahmed Kamel Abdel; Lansky, Alexandra J; Settlage, Richard A; Muhs, Bart E

    2014-10-01

    To assess safety and effectiveness of a nitinol retrievable inferior vena cava (IVC) filter in patients who require caval interruption to protect against pulmonary embolism (PE). Two hundred patients with temporary indications for an IVC filter were enrolled in this prospective, multicenter clinical study. Patients undergoing filter implantation were to be followed for 2 years or for 30 days after filter retrieval. At the time of the present interim report, all 200 patients had been enrolled in the study, and 160 had undergone a retrieval attempt or been followed to 6 months with their filter in place. Primary study endpoints included technical and clinical success of filter placement and retrieval. Patients were also evaluated for recurrent PE, new or worsening deep vein thrombosis, and filter migration, fracture, penetration, and tilt. Clinical success of placement was achieved in 94.5% of patients (172 of 182), with a one-sided lower limit of the 95% confidence interval of 90.1%. Technical success rate of filter placement was 99.5%. Technical success rate of retrieval was 97.3%; 108 filters were retrieved in 111 attempts. In two cases, the filter apex could not be engaged with a snare, and one device was engaged but could not be removed. Filter retrievals occurred at a mean indwell time of 165 days (range, 5-632 d). There were no instances of filter fracture, migration, or tilt greater than 15° at the time of retrieval or 6-month follow-up. In this interim report, the nitinol retrievable IVC filter provided protection against pulmonary embolism, and the device could be retrieved with a low rate of complications. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  16. Nivolumab in Treating Patients With Recurrent and/or Metastatic Nasopharyngeal Cancer

    ClinicalTrials.gov

    2018-05-23

    Nasopharyngeal Nonkeratinizing Carcinoma; Recurrent Nasopharynx Carcinoma; Stage III Nasopharyngeal Carcinoma AJCC v7; Stage IV Nasopharyngeal Carcinoma AJCC v7; Stage IVA Nasopharyngeal Carcinoma AJCC v7; Stage IVB Nasopharyngeal Carcinoma AJCC v7; Stage IVC Nasopharyngeal Carcinoma AJCC v7

  17. New approach to enhance and evaluate the performance of vehicle-infrastructure integration and its communication systems, final report.

    DOT National Transportation Integrated Search

    2010-09-01

    Initial research studied the use of wireless local area networks (WLAN) protocols in Inter-Vehicle Communications : (IVC) environments. The protocols performance was evaluated in terms of measuring throughput, jitter time and : delay time. This re...

  18. Effect of 2 Bedding Materials on Ammonia Levels in Individually Ventilated Cages

    PubMed Central

    Koontz, Jason M; Kumsher, David M; III, Richard Kelly; Stallings, Jonathan D

    2016-01-01

    This study sought to identify an optimal rodent bedding and cage-change interval to establish standard procedures for the IVC in our rodent vivarium. Disposable cages were prefilled with either corncob or α-cellulose bedding and were used to house 2 adult Sprague–Dawley rats (experimental condition) or contained no animals (control). Rats were observed and intracage ammonia levels measured daily for 21 d. Intracage ammonia accumulation became significant by day 8 in experimental cages containing α-cellulose bedding, whereas experimental cages containing corncob bedding did not reach detectable levels of ammonia until day 14. In all 3 experimental cages containing α-cellulose, ammonia exceeded 100 ppm (our maximum acceptable limit) by day 11. Two experimental corncob cages required changing at days 16 and 17, whereas the remaining cage containing corncob bedding lasted the entire 21 d without reaching the 100-ppm ammonia threshold. These data suggests that corncob bedding provides nearly twice the service life of α-cellulose bedding in the IVC system. PMID:26817976

  19. Budd-Chiari Syndrome Due to Protein C Deficiency: A Rare Disorder to cause Chronic Liver Disease.

    PubMed

    Begum, Rukshana; Mahtab, Mamun Al; Mamun, Ayub Al; Moben, Ahmed Lutful; Hossain, Sharker Mohammad Shahadat; Das, Dulal Chandra; Malakar, Debraj; Or Rashid, Harun; Roy, Partho Protim; Rahman, Salimur

    2016-01-01

    The Budd-Chiari syndrome (BCS) is a rare disorder due to chronic liver disease (CLD), which is caused by the obstruction of hepatic venous outflow that can be located at any place from the small hepatic venules up to the entrance of the inferior vena cava (IVC) into the right atrium. Among the causes of BCS, the rarer one is coagulation factor deficiencies. Here, we report a case of BCS associated with deficiency of protein C resulting in thrombus in IVC. The patient was a 50-year-old male, who had been suffering from recurrent abdominal and leg swelling for a long period of 7 years. He was evaluated thoroughly, and other causes of liver cirrhosis were excluded. Begum R, Al Mahtab M, Al Mamun A, Moben AL, Hossain SMS, Das DC, Malakar D, Rashid HO, Roy PP, Rahman S. Budd-Chiari Syndrome Due to Protein C Deficiency: A Rare Disorder to cause Chronic Liver Disease. Euroasian J Hepato-Gastroenterol 2016;6(2):194-197.

  20. Effect of 2 Bedding Materials on Ammonia Levels in Individually Ventilated Cages.

    PubMed

    Koontz, Jason M; Kumsher, David M; Kelly, Richard; Stallings, Jonathan D

    2016-01-01

    This study sought to identify an optimal rodent bedding and cage-change interval to establish standard procedures for the IVC in our rodent vivarium. Disposable cages were prefilled with either corncob or α-cellulose bedding and were used to house 2 adult Sprague-Dawley rats (experimental condition) or contained no animals (control). Rats were observed and intracage ammonia levels measured daily for 21 d. Intracage ammonia accumulation became significant by day 8 in experimental cages containing α-cellulose bedding, whereas experimental cages containing corncob bedding did not reach detectable levels of ammonia until day 14. In all 3 experimental cages containing α-cellulose, ammonia exceeded 100 ppm (our maximum acceptable limit) by day 11. Two experimental corncob cages required changing at days 16 and 17, whereas the remaining cage containing corncob bedding lasted the entire 21 d without reaching the 100-ppm ammonia threshold. These data suggests that corncob bedding provides nearly twice the service life of α-cellulose bedding in the IVC system.

  1. Treatment of Superior Vena Cava (SVC) Syndrome and Inferior Vena Cava (IVC) Thrombosis in a Patient with Colorectal Cancer: Combination of SVC Stenting and IVC Filter Placement to Palliate Symptoms and Pave the Way for Port Implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sauter, Alexander; Triller, Juergen; Schmidt, Felix

    Thrombosis of the inferior vena cava is a life-threatening complication in cancer patients leading to pulmonary embolism. These patients can also be affected by superior vena cava syndrome causing dyspnea followed by trunk or extremity swelling. We report the case of a 61-year-old female suffering from an extended colorectal tumor who became affected by both of the mentioned complications. Due to thrombus formation within the right vena jugularis interna, thrombosis of the inferior vena cava, and superior vena cava syndrome, a combined interventional procedure via a left jugular access with stenting of the superior vena cava and filter placement intomore » the inferior vena cava was performed As a consequence, relief of the patient's symptoms, prevention of pulmonary embolism, and paving of the way for further venous chemotherapy were achieved.« less

  2. ACTOplus Met XR in Treating Patients With Stage I-IV Oral Cavity or Oropharynx Cancer Undergoing Definitive Treatment

    ClinicalTrials.gov

    2018-03-02

    Oral Cavity Neoplasm; Oropharyngeal Neoplasm; Stage I Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage I Oropharyngeal Squamous Cell Carcinoma AJCC v6 and v7; Stage II Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage II Oropharyngeal Squamous Cell Carcinoma AJCC v6 and v7; Stage III Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage III Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IV Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IV Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVA Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVA Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVB Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVC Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVC Oropharyngeal Squamous Cell Carcinoma AJCC v7

  3. Heating mechanism(s) for transition layers in giants

    NASA Technical Reports Server (NTRS)

    Bohm-Vitense, Erika; Mena-Werth, Jose

    1991-01-01

    The emission-line fluxes of lines originating in the lower parts of the transition layers between stellar chromospheres and coronas are studied. Simon and Drake (1989) suspect different heating mechanisms for 'hot' and cool stars. Changes in the flux ratios for the C IV to C II emission lines support this suspicion. Large C IV/C II line flux ratios appear to be indicative of magnetically controlled heating. A correlation between excess continuum flux around 1950 A and C II emission-line fluxes are confirmed for the cooler giants (late F and cooler). Excess continuum flux correlates positively with large C IV/C II line flux ratio. The excess continuum flux corresponds to an increase in temperature by several hundred degrees in layers with a mean optical depth of about 0.03. For chromospherically active stars these layers experience a mechanical flux deposition of the order of 1 percent of the total radiative flux. This flux is tentatively identified as an MHD wave flux similar to Alfven waves.

  4. The Usefulness of Patch Repair Using the Repermeabilized Umbilical Vein of the Round Ligament for Hepatobiliary Malignancies.

    PubMed

    Takahashi, Michiro; Saiura, Akio; Takahashi, Yu

    2017-11-01

    Patients with tumors invading major veins may require combined resection and reconstruction. However, venous reconstruction often demands complex hepatobiliary and vascular surgical procedures. In this study, we report a simple patch repair technique for venous reconstruction using the repermeabilized umbilical vein of the round ligament. We reviewed the outcomes of eleven patients who underwent venous wedge resection and patch repair using the repermeabilized umbilical vein of the round ligament at our institution. Procurement of the round ligament and method of making a patch is simple. The duration of anastomosis was approximately 15 min. Eight patients (73%) underwent hepatic resection followed by hepatic vein reconstruction; two (18%) pancreaticoduodenectomy followed by inferior vena cava (IVC) reconstruction; one (9%) hepatic resection followed by IVC reconstruction. Although one reconstructed vein became narrowed, the other ten veins were patent after surgery. Patch repair using the repermeabilized umbilical vein of the round ligament is a simple and useful technique.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uller, Wibke, E-mail: wibke.uller@klinik.uni-regensburg.de; Knoppke, Birgit; Schreyer, Andreas G.

    Purpose: Evaluation of the efficacy and safety of percutaneous treatment of vascular stenoses and occlusions in pediatric liver transplant recipients. Methods: Fifteen children (mean age 8.3 years) underwent interventional procedures for 18 vascular complications after liver transplantation. Patients had stenoses or occlusions of portal veins (n = 8), hepatic veins (n = 3), inferior vena cava (IVC; n = 2) or hepatic arteries (n = 5). Technical and clinical success rates were evaluated. Results: Stent angioplasty was performed in seven cases (portal vein, hepatic artery and IVC), and sole balloon angioplasty was performed in eight cases. One child underwent thrombolysismore » (hepatic artery). Clinical and technical success was achieved in 14 of 18 cases of vascular stenoses or occlusions (mean follow-up 710 days). Conclusion: Pediatric interventional radiology allows effective and safe treatment of vascular stenoses after pediatric liver transplantation (PLT). Individualized treatment with special concepts for each pediatric patient is necessary. The variety, the characteristics, and the individuality of interventional management of all kinds of possible vascular stenoses or occlusions after PLT are shown.« less

  6. Aligned metal absorbers and the ultraviolet background at the end of reionization

    NASA Astrophysics Data System (ADS)

    Doughty, Caitlin; Finlator, Kristian; Oppenheimer, Benjamin D.; Davé, Romeel; Zackrisson, Erik

    2018-04-01

    We use observations of spatially aligned C II, C IV, Si II, Si IV, and O I absorbers to probe the slope and intensity of the ultraviolet background (UVB) at z ˜ 6. We accomplish this by comparing observations with predictions from a cosmological hydrodynamic simulation using three trial UVBs applied in post-processing: a spectrally soft, fluctuating UVB calculated using multifrequency radiative transfer; a soft, spatially uniform UVB; and a hard, spatially uniform `quasars-only' model. When considering our paired high-ionization absorbers (C IV/Si IV), the observed statistics strongly prefer the hard, spatially uniform UVB. This echoes recent findings that cosmological simulations generically underproduce strong C IV absorbers at z > 5. A single low/high ionization pair (Si II/Si IV), by contrast, shows a preference for the HM12 UVB, whereas two more (C II/C IV and O I/C IV) show no preference for any of the three UVBs. Despite this, future observations of specific absorbers, particularly Si IV/C IV, with next-generation telescopes probing to lower column densities should yield tighter constraints on the UVB.

  7. 78 FR 29041 - Sulfoxaflor; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-17

    ... Modeling System (PRZM/EXAMS) and Screening Concentration in Ground Water (SCI-GROW) models, the estimated.... The following list of North American Industrial Classification System (NAICS) codes is not intended to... response to these comments is discussed in Unit IV.C. Based upon review of the data supporting the petition...

  8. "What D'ya Mean, Project SOL-FA?"

    ERIC Educational Resources Information Center

    Hardman, Olga S.

    1981-01-01

    Since 1977, Project Sol-fa, funded with an ESEA Title IV-C grant has provided Harrison County primary teachers with inservice training in the Kodaly method of music education. This article provides information on program funding, costs, and accomplishments. Evaluation forms and the inservice syllabus are appended. (SJL)

  9. Nivolumab and Ipilimumab in Treating Patients With Metastatic/Recurrent ACC of All Sites and Non-ACC Salivary Gland Cancer

    ClinicalTrials.gov

    2018-04-12

    Major Salivary Gland Carcinoma; Minor Salivary Gland Carcinoma; Recurrent Salivary Gland Carcinoma; Stage IV Major Salivary Gland Carcinoma; Stage IVA Major Salivary Gland Carcinoma; Stage IVB Major Salivary Gland Carcinoma; Stage IVC Major Salivary Gland Carcinoma

  10. 75 FR 43537 - Mortgagee Review Board: Administrative Actions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-26

    ...., Fountain Valley, CA. 469. Ironwood Lending, Inc., Phoenix, AZ. 470. IVC Mortgage Group, Inc., Des Plaines..., connected, or had authorization from HUD for its Web site. 3. Americare Investment Group, Inc. d/b/a Premier... Notice of Administrative Action to Americare Investment Group, Inc. (Americare) permanently withdrawing...

  11. Student Learning in Student Services Extended Opportunity Program & Services

    ERIC Educational Resources Information Center

    Soltani, Parisa

    2013-01-01

    The purpose of this mixed methods study was to investigate the relationship between student learning and participation in Equal Opportunity Programs and Services (EOP&S) at Irvine Valley College (IVC). An embedded survey design was developed using William Sedlacek's non-cognitive questionnaire (NCQ), items from the Community College Survey of…

  12. 28 CFR 904.2 - Interpretation of the criminal history record screening requirement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Interpretation of the criminal history... PRIVACY COMPACT COUNCIL STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.2 Interpretation of the criminal history record screening requirement. Compact Article IV(c) provides that “Any record obtained...

  13. 28 CFR 904.2 - Interpretation of the criminal history record screening requirement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Interpretation of the criminal history... PRIVACY COMPACT COUNCIL STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.2 Interpretation of the criminal history record screening requirement. Compact Article IV(c) provides that “Any record obtained...

  14. 28 CFR 904.2 - Interpretation of the criminal history record screening requirement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Interpretation of the criminal history... PRIVACY COMPACT COUNCIL STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.2 Interpretation of the criminal history record screening requirement. Compact Article IV(c) provides that “Any record obtained...

  15. 28 CFR 904.2 - Interpretation of the criminal history record screening requirement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Interpretation of the criminal history... PRIVACY COMPACT COUNCIL STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.2 Interpretation of the criminal history record screening requirement. Compact Article IV(c) provides that “Any record obtained...

  16. 28 CFR 904.2 - Interpretation of the criminal history record screening requirement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Interpretation of the criminal history... PRIVACY COMPACT COUNCIL STATE CRIMINAL HISTORY RECORD SCREENING STANDARDS § 904.2 Interpretation of the criminal history record screening requirement. Compact Article IV(c) provides that “Any record obtained...

  17. Project SAIL: An Evaluation of a Dropout Prevention Program.

    ERIC Educational Resources Information Center

    Thompson, John L.; And Others

    Project SAIL (Student Advocates Inspire Learning) is a Title IV-C Project located in Hopkins, Minnesota, designed to prevent students from dropping out of school by keeping them successfully involved in the mainstream environment. This study presents a review of other dropout prevention approaches, describes the intervention strategies involved in…

  18. U.S. EPA, Pesticide Product Label, CS-146 CRYSTAL CRESYLIC DISINFECTANT, 10/16/1967

    EPA Pesticide Factsheets

    2011-04-14

    ... Hal'lllful if :-:wallo\\\\'t'd, (j'a~c'lI:-:c' if irritation dl'\\'elops, .\\vl)id c'olltad of III:tt I'l'ia I with ",kill alld ",n':-:, TI~)( )'1')<;: IlIt('l'IIal-< ;ivC' raw ('gg; whitt', Illilk ...

  19. The development of a post-test diagnostic system for rocket engines

    NASA Technical Reports Server (NTRS)

    Zakrajsek, June F.

    1991-01-01

    An effort was undertaken by NASA to develop an automated post-test, post-flight diagnostic system for rocket engines. The automated system is designed to be generic and to automate the rocket engine data review process. A modular, distributed architecture with a generic software core was chosen to meet the design requirements. The diagnostic system is initially being applied to the Space Shuttle Main Engine data review process. The system modules currently under development are the session/message manager, and portions of the applications section, the component analysis section, and the intelligent knowledge server. An overview is presented of a rocket engine data review process, the design requirements and guidelines, the architecture and modules, and the projected benefits of the automated diagnostic system.

  20. 40 CFR 1036.615 - Engines with Rankine cycle waste heat recovery and hybrid powertrains.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... energy recovery systems. (a) Pre-transmission hybrid powertrains. Test pre-transmission hybrid powertrains with the hybrid engine test procedures of 40 CFR part 1065 or with the post-transmission test... tested using the hybrid engine test procedures of 40 CFR part 1065 or using the post-transmission test...

  1. 40 CFR 1054.690 - What bond requirements apply for certified engines?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Before introducing certified engines into U.S. commerce, you must post a bond to cover any potential... importing engines that have been certified by someone else. Note that you might also post bond under this... test conducted by EPA officials or having been found by EPA to be noncompliant under applicable...

  2. 40 CFR 1054.690 - What bond requirements apply for certified engines?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Before introducing certified engines into U.S. commerce, you must post a bond to cover any potential... importing engines that have been certified by someone else. Note that you might also post bond under this... test conducted by EPA officials or having been found by EPA to be noncompliant under applicable...

  3. 40 CFR 1054.690 - What bond requirements apply for certified engines?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Before introducing certified engines into U.S. commerce, you must post a bond to cover any potential... importing engines that have been certified by someone else. Note that you might also post bond under this... test conducted by EPA officials or having been found by EPA to be noncompliant under applicable...

  4. 40 CFR 1054.690 - What bond requirements apply for certified engines?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Before introducing certified engines into U.S. commerce, you must post a bond to cover any potential... importing engines that have been certified by someone else. Note that you might also post bond under this... test conducted by EPA officials or having been found by EPA to be noncompliant under applicable...

  5. 40 CFR 1054.690 - What bond requirements apply for certified engines?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Before introducing certified engines into U.S. commerce, you must post a bond to cover any potential... importing engines that have been certified by someone else. Note that you might also post bond under this... test conducted by EPA officials or having been found by EPA to be noncompliant under applicable...

  6. 40 CFR 63.10685 - What are the requirements for the control of contaminants from scrap?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... not charge to a furnace metallic scrap that contains scrap from motor vehicle bodies, engine blocks... vehicle bodies, engine blocks, oil filters, oily turnings, machine shop borings, transformers or... restriction does not apply to any post-consumer engine blocks, post-consumer oil filters, or oily turnings...

  7. 40 CFR 63.10685 - What are the requirements for the control of contaminants from scrap?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... not charge to a furnace metallic scrap that contains scrap from motor vehicle bodies, engine blocks... vehicle bodies, engine blocks, oil filters, oily turnings, machine shop borings, transformers or... restriction does not apply to any post-consumer engine blocks, post-consumer oil filters, or oily turnings...

  8. 40 CFR 63.10685 - What are the requirements for the control of contaminants from scrap?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... not charge to a furnace metallic scrap that contains scrap from motor vehicle bodies, engine blocks... vehicle bodies, engine blocks, oil filters, oily turnings, machine shop borings, transformers or... restriction does not apply to any post-consumer engine blocks, post-consumer oil filters, or oily turnings...

  9. Post-Graduation Plans of International Science and Engineering Doctoral Students Attending U.S. Universities

    ERIC Educational Resources Information Center

    Ugwu, Dorothy N.; Adamuti-Trache, Maria

    2017-01-01

    This study examines the post-graduation plans of international science and engineering doctoral students at a public research-intensive university, and the extent to which graduate school experiences influence post-graduation plans. The study is grounded in Tinto's Integration Model as well as Berry's Acculturation Model. Study findings highlight…

  10. 40 CFR 94.209 - Special provisions for post-manufacture marinizers and small-volume manufacturers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-manufacture marinizers and small-volume manufacturers. 94.209 Section 94.209 Protection of Environment... COMPRESSION-IGNITION ENGINES Certification Provisions § 94.209 Special provisions for post-manufacture... demonstrate one of the following: (1) It is a post-manufacture marinizer and that the base engines used for...

  11. 78 FR 36369 - Heavy-Duty Engine and Vehicle, and Nonroad Technical Amendments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-17

    ... reference to post-transmissions systems in the hybrid engine test requirements in 40 CFR part 1036 and 49... requirements for testing post-transmission hybrids using a vehicle test. The agencies anticipate that there... out in the regulation specify how to test post-transmission systems. Specifically, 40 CFR 1037.525, 40...

  12. Career Services | College of Engineering & Applied Science

    Science.gov Websites

    Engineering & Applied Science uses the university's PantherJobs to help students post resumes, search and ' resumes, post available positions and schedule interviews. Co-ops and Internships Co-ops and Internships

  13. Engineering Evaluation of Post-Liquefaction Residual Strengths

    DOT National Transportation Integrated Search

    1999-01-10

    The past decade has seen rapid advances in the understanding of post-liquefaction residual strength (and associated stress-deformation behavior). Despite this progress, the intrinsic difficulties involved continue to render the engineering assessment...

  14. An Investigation of Engineering Students' Post-Graduation Plans inside or outside of Engineering

    ERIC Educational Resources Information Center

    Ro, Hyun Kyoung

    2011-01-01

    The question of students' post-graduation plans is a critical one for the field of engineering as both industry and higher education institutions seek to understand how to increase the production of highly-skilled individuals for the STEM workforce. Despite the concern, there are but a few empirical studies that examine how students' academic…

  15. 40 CFR 85.1403 - Particulate standard for pre-1994 model year urban buses effective at time of engine rebuild or...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... section. (iii)(A) Pre-rebuild particulate emission levels and projected post-rebuild particulate emission... specified in the following table. The appropriate particulate level, pre-rebuild or post-rebuild, shall be... of engine Pre-rebuild particulate level (g/bhp-hr) Projected post-rebuild particulate level (g/bhp-hr...

  16. 40 CFR 85.1403 - Particulate standard for pre-1994 model year urban buses effective at time of engine rebuild or...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... section. (iii)(A) Pre-rebuild particulate emission levels and projected post-rebuild particulate emission... specified in the following table. The appropriate particulate level, pre-rebuild or post-rebuild, shall be... of engine Pre-rebuild particulate level (g/bhp-hr) Projected post-rebuild particulate level (g/bhp-hr...

  17. 40 CFR 85.1403 - Particulate standard for pre-1994 model year urban buses effective at time of engine rebuild or...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... section. (iii)(A) Pre-rebuild particulate emission levels and projected post-rebuild particulate emission... specified in the following table. The appropriate particulate level, pre-rebuild or post-rebuild, shall be... of engine Pre-rebuild particulate level (g/bhp-hr) Projected post-rebuild particulate level (g/bhp-hr...

  18. 40 CFR 85.1403 - Particulate standard for pre-1994 model year urban buses effective at time of engine rebuild or...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... section. (iii)(A) Pre-rebuild particulate emission levels and projected post-rebuild particulate emission... specified in the following table. The appropriate particulate level, pre-rebuild or post-rebuild, shall be... of engine Pre-rebuild particulate level (g/bhp-hr) Projected post-rebuild particulate level (g/bhp-hr...

  19. 40 CFR 85.1403 - Particulate standard for pre-1994 model year urban buses effective at time of engine rebuild or...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... section. (iii)(A) Pre-rebuild particulate emission levels and projected post-rebuild particulate emission... specified in the following table. The appropriate particulate level, pre-rebuild or post-rebuild, shall be... of engine Pre-rebuild particulate level (g/bhp-hr) Projected post-rebuild particulate level (g/bhp-hr...

  20. 50 CFR 648.85 - Special management programs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... assessment of the U.S./Canada shared resources for GB cod, haddock and yellowtail flounder shall occur. (C... comply with the restrictions and conditions in paragraphs (a)(3)(ii)(A) through (C) of this section... trip (e.g., the possession restrictions specified in paragraph (a)(3)(iv)(C)(4) of this section), and...

  1. 78 FR 52694 - Price Cap Rules for Certain Postal Rate Adjustments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-26

    ... Sec. 3010.12(c) relating to the filing of information concerning new discounts and surcharges are... and IV.C. Section 3010.23(b) reflects revisions that require the percentage change in rates for a... authority may only be applied after applying the annual limitation. Section 3010.26(c)(2) reflects revisions...

  2. Effect of 2 Bedding Materials on Ammonia Levels in Individually Ventilated Cages

    DTIC Science & Technology

    2016-01-01

    primarily from urease -positive bacteria, which metabolize urea from the urine and feces of the animals.8 Therefore, am- monia levels are...proportional to the amounts of wet urine and urease -positive bacteria present in the cage. IVC systems help to reduce the levels of both urine and urease

  3. Validation Report for the Title IV-C Health Through Science Project, 1979-80.

    ERIC Educational Resources Information Center

    McLean, James E.; And Others

    Three objectives were identified regarding the Health Through Science Project, a comprehensive K-12 health project designed to increase student knowledge and understanding of health topic. Topics composing the core curriculum of the project were nutrition, safety, family living skills, personal hygiene and health, and human reproduction. Upon full…

  4. Nutrition Education Development Project. ESEA Title IVC Project. Pamphlet File.

    ERIC Educational Resources Information Center

    Luzerne Intermediate Unit 18, Kingston, PA.

    This compilation of pamphlets and other educational materials on current issues in nutrition provides elementary and secondary teachers with a list of free or inexpensive materials to help them implement nutrition education into the existing curriculum. This list, organized in alphabetical order by topic, contains 293 entries and each one includes…

  5. Evaluation of Title IV-C ESEA Projects, 1977-1978. Annual Report. Report #7909.

    ERIC Educational Resources Information Center

    Philadelphia School District, PA. Office of Research and Evaluation.

    Reports of fourteen program descriptions and evaluations are presented. All but two were produced by the Department of Federal Evaluation Resource Services, a model state evaluation project. The projects varied in purpose; budget; grades served; and number of students, teachers, and administrators participating. Reports vary in detail from one to…

  6. Integrating bio-prosthetic valves in the Fontan operation - Novel treatment to control retrograde flow in caval veins

    NASA Astrophysics Data System (ADS)

    Vukicevic, Marija; Conover, Timothy; Zhou, Jian; Hsia, Tain-Yen; Figliola, Richard

    2012-11-01

    For a child born with only one functional heart ventricle, the sequence of palliative surgeries typically culminates in the Fontan operation. This procedure is usually successful initially, but leads to later complications, for reasons not fully understood. Examples are respiratory-dependent retrograde flows in the caval and hepatic veins, and increased pulmonary vascular resistance (PVR), hypothesized to be responsible for elevated pressure in the liver and disease of the liver and intestines. Here we study the parameters responsible for retrograde flows in the inferior vena cava (IVC) and hepatic vein (HV), and investigate two novel interventions to control retrograde flow: implanting either a Medtronic Contegra valved conduit or an Edwards lifescience pericardial aortic valve in the IVC or HV. We performed the experiments in a multi-scale, patient specific mock circuit, with normal and elevated PVR, towards the optimization of the Fontan circulation. The results show that both valves can significantly reduce retrograde flows in the veins, suggesting potential advantages in the treatment of the patients with congenital heart diseases. Fondation Leducq

  7. Prostaglandin E2 releases ovine fetal ACTH from a site not perfused by the carotid vasculature.

    PubMed

    Cudd, T A; Wood, C E

    1992-07-01

    Placental prostaglandin E2 (PGE2) is thought to influence the ovine fetal adrenocortical system to control the timing of parturition. We investigated whether physiological infusions of PGE2 increase fetal immunoreactive adrenocorticotropin (iACTH) at the fetal brain or pituitary or at a site not perfused by the carotid vasculature. PGE2 was infused into the carotid artery (ica) at 0 (n = 5), 10 (n = 5), or 100 ng/min (n = 4) or into the vena cava (ivc) at 10 (n = 5) or 100 ng/min (n = 5) for 30 min in fetuses between 119 and 130 days gestation. Blood gases, vasopressin, cortisol, and arterial and central venous pressure were unchanged. Heart rate increased only in the 100 ng/min ica group. iACTH increased only in the 100 ng/min ivc group from 59 +/- 26 to 180 +/- 73 pg/ml. We conclude that PGE2 infused to create physiological plasma concentrations similar to those at the end of gestation stimulates iACTH from a site other than the fetal brain or pituitary.

  8. Lung volumes during sustained microgravity on Spacelab SLS-1

    NASA Technical Reports Server (NTRS)

    Elliott, Ann R.; Prisk, Gordon Kim; Guy, Harold J. B.; West, John B.

    1994-01-01

    Gravity is known to influence the topographical gradients of pulmonary ventilation, perfusion, and pleural pressures. The effect of sustained microgravity on lung volumes has not previously been investigated. Pulmonary function tests were performed by four subjects before, during, and after 9 days of microgravity exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box and flowmeter system and a respiratory mass spectrometer. Measurements of tidal volume (V(sub T)), expiratory reserve volume (ERV), inspiratory and expiratory vital capacities (IVC, EVC), functional residual capacity (FRC), and residual volume (RV) were made. During microgravity, V(sub T) decreased by 15%. IVC and EVC were slightly reduced during the first 24 hrs of microgravity and returned to 1 g standing values within 72 hrs after the onset of microgravity. FRC was reduced by 15% and ERV decreased by 10-20%. RV was significantly reduced by 18%. The reductions in FRC, ERV, and V(sub T) during microgravity are probably due to the cranial shift of the diaphragm and an increase in intrathoracic blood volume.

  9. Advanced Techniques for Removal of Retrievable Inferior Vena Cava Filters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iliescu, Bogdan; Haskal, Ziv J., E-mail: ziv2@mac.com

    Inferior vena cava (IVC) filters have proven valuable for the prevention of primary or recurrent pulmonary embolism in selected patients with or at high risk for venous thromboembolic disease. Their use has become commonplace, and the numbers implanted increase annually. During the last 3 years, in the United States, the percentage of annually placed optional filters, i.e., filters than can remain as permanent filters or potentially be retrieved, has consistently exceeded that of permanent filters. In parallel, the complications of long- or short-term filtration have become increasingly evident to physicians, regulatory agencies, and the public. Most filter removals are uneventful,more » with a high degree of success. When routine filter-retrieval techniques prove unsuccessful, progressively more advanced tools and skill sets must be used to enhance filter-retrieval success. These techniques should be used with caution to avoid damage to the filter or cava during IVC retrieval. This review describes the complex techniques for filter retrieval, including use of additional snares, guidewires, angioplasty balloons, and mechanical and thermal approaches as well as illustrates their specific application.« less

  10. A study of ultraviolet absorption lines through the complete Galactic halo by the analysis of HST faint object spectrograph spectra of active Galactic nuclei, 1

    NASA Technical Reports Server (NTRS)

    Burks, Geoffrey S.; Bartko, Frank; Shull, J. Michael; Stocke, John T.; Sachs, Elise R.; Burbidge, E. Margaret; Cohen, Ross D.; Junkkarinen, Vesa T.; Harms, Richard J.; Massa, Derck

    1994-01-01

    The ultraviolet (1150 - 2850 A) spectra of a number of active galactic nuclei (AGNs) observed with the Hubble Space Telescope (HST) Faint Object Spectrograph (FOS) have been used to study the properties of the Galactic halo. The objects that served as probes are 3C 273, PKS 0454-220, Pg 1211+143, CSO 251, Ton 951, and PG 1351+640. The equivalent widths of certain interstellar ions have been measured, with special attention paid to the C IV/C II and Si IV/Si II ratios. These ratios have been intercompared, and the highest values are found in the direction of 3C 273, where C IV/C II = 1.2 and Si IV/Si II greater than 1. These high ratios may be due to a nearby supernova remnant, rather than to ionized gas higher up in the Galactic halo. Our data give some support to the notion that QSO metal-line systems may arise from intervening galaxies which contain high supernova rates, galactic fountains, and turbulent mixing layers.

  11. SB-715992 in Treating Patients With Recurrent or Metastatic Head and Neck Cancer

    ClinicalTrials.gov

    2017-01-13

    Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Larynx; Stage IV Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IV Squamous Cell Carcinoma of the Oropharynx; Stage IV Verrucous Carcinoma of the Larynx; Stage IV Verrucous Carcinoma of the Oral Cavity; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity

  12. Primary Renal Rhabdomyosarcoma in an Adolescent With Tumor Thrombosis in the Inferior Vena Cava and Right Atrium: A Case Report and Review of the Literature.

    PubMed

    Lin, Wei-Ching; Chen, Jeon-Hor; Westphalen, Antonio; Chang, Han; Chiang, I-Ping; Chen, Cheng-Hong; Wu, Hsi-Chin; Lin, Chien-Heng

    2016-05-01

    Although the second peak of the age distribution of rhabdomyosarcoma (RMS) is at adolescence, renal RMS is extremely rare at this age group. This tumor is indistinguishable from other renal tumors based on clinical and imaging findings, and the diagnosis relies on histology and immunohistochemical staining. We report a unique case of adolescent renal RMS associated with tumor thrombus extending into the inferior vena cava (IVC) and right atrium.An 18-year-old female adolescent presented with shortness of breath and palpitations, associated with right flank discomfort, and hematuria. A pleomorphic-type renal RMS with Budd-Chiari syndrome and arrhythmia induced by IVC and RA thrombosis was diagnosed. Despite complete tumor resection, the patient developed multiple lung metastases a month after surgery. Chemotherapy was recommended, but the patient declined. She died within a year of the initial operation.Adolescent renal RMS is rare and associated with poor outcome. Early aggressive multimodal therapy seems to be appropriate, in particular, in the presence of tumor thrombosis.

  13. Optimization of an idealized Y-Shaped Extracardiac Fontan Baffle

    NASA Astrophysics Data System (ADS)

    Yang, Weiguang; Feinstein, Jeffrey; Mohan Reddy, V.; Marsden, Alison

    2008-11-01

    Research has showed that vascular geometries can significantly impact hemodynamic performance, particularly in pediatric cardiology, where anatomy varies from one patient to another. In this study we optimize a newly proposed design for the Fontan procedure, a surgery used to treat single ventricle heart patients. The current Fontan procedure connects the inferior vena cava (IVC) to the pulmonary arteries (PA's) via a straight Gore-Tex tube, forming a T-shaped junction. In the Y-graft design, the IVC is connected to the left and right PAs by two branches. Initial studies on the Y-graft design showed an increase in efficiency and improvement in flow distribution compared to traditional designs in a single patient-specific model. We now optimize an idealized Y-graft model to refine the design prior to patient testing. A derivate-free optimization algorithm using Kriging surrogate functions and mesh adaptive direct search is coupled to a 3-D finite element Navier-Stokes solver. We will present optimization results for rest and exercise conditions and examine the influence of energy efficiency, wall shear stress, pulsatile flow, and flow distribution on the optimal design.

  14. Ultrasound measurement of inferior vena cava diameters by emergency department nurses.

    PubMed

    De Lorenzo, Robert A; Holbrook-Emmons, Victoria L

    2014-01-01

    Sonographic measurement of the inferior vena cava (IVC) diameter is a potentially important noninvasive estimate of fluid status. We researched whether nurses without prior ultrasonography experience could accurately obtain vena cava diameter measurements on models and subjects in comparison with those obtained by an expert sonographer. The design was a prospective educational study using a pre- and posttest of knowledge and a comparison of imaging performance between a subject and an expert sonographer. The setting was an urban teaching medical center with emergency nurses and a convenience sample of volunteer patients selected from the emergency department (ED). Nurses completed a written survey and a pretest to document prior training and experience in ultrasonography and assess baseline knowledge. A structured training program (3.5 hr in length) was provided over three sessions. Training consisted of didactic presentations, practice on phantoms (manikin models designed to provide the sonographic image of the human body when scanned by a trainee) and classmates, and one volunteer patient in the ED. Each nurse then measured IVC diameters on three different volunteer patients in transverse and longitudinal orientations using frozen images. An expert sonographer, blinded to subject results, performed the same examination. Correlations were determined, and a posttraining written examination was completed and results compared with the pretest using a pair-wise t test. Fourteen nurses, with a mean of 8 years' nursing experience (range = 2-18 years), participated. Nurse-expert R value correlation for the longitudinal orientation was 0.68 (95% confidence interval [CI] [0.35, 0.76]) and 0.59 (95% CI [0.47, 0.81]) for the transverse orientation. Posttest scores improved 8.2 percentage points (95% CI [4.0, 12.4]) from 83.3% to 91.5%. Following a brief training course, nurses with no prior sonography experience show moderately good correlation measuring the IVC diameter as compared with expert measurements, with better performance demonstrated in the longitudinal orientation.

  15. Retrievable Inferior Vena Cava Filters in Trauma Patients: Prevalence and Management of Thrombus Within the Filter.

    PubMed

    Pan, Y; Zhao, J; Mei, J; Shao, M; Zhang, J; Wu, H

    2016-12-01

    The incidence of thrombus was investigated within retrievable filters placed in trauma patients with confirmed DVT at the time of retrieval and the optimal treatment for this clinical scenario was assessed. A technique called "filter retrieval with manual negative pressure aspiration thrombectomy" for management of filter thrombus was introduced and assessed. The retrievable filters referred for retrieval between January 2008 and December 2015 were retrospectively reviewed to determine the incidence of filter thrombus on a pre-retrieval cavogram. The clinical outcomes of different managements for thrombus within filters were recorded and analyzed. During the study 764 patients having Aegisy Filters implanted were referred for filter removal, from which 236 cases (134 male patients, mean age 50.2 years) of thrombus within the filter were observed on initial pre-retrieval IVC venogram 12-39 days after insertion (average 16.9 days). The incidence of infra-filter thrombus was 30.9%, and complete occlusion of the filter bearing IVC was seen in 2.4% (18) of cases. Retrieval was attempted in all 121 cases with small clots using a regular snare and sheath technique, and was successful in 120. A total of 116 cases with massive thrombus and IVC occlusion by thrombus were treated by CDT and/or the new retrieval technique. Overall, 213 cases (90.3%) of thrombus in the filter were removed successfully without PE. A small thrombus within the filter can be safely removed without additional management. CDT for reduction of the clot burden in filters was effective and safe. Filter retrieval with manual negative pressure aspiration thrombectomy seemed reasonable and valuable for management of massive thrombus within filters in some patients. Full assessment of the value and safety of this technique requires additional studies. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  16. Adding point of care ultrasound to assess volume status in heart failure patients in a nurse-led outpatient clinic. A randomised study

    PubMed Central

    Gundersen, Guri Holmen; Norekval, Tone M; Haug, Hilde Haugberg; Skjetne, Kyrre; Kleinau, Jens Olaf; Graven, Torbjorn; Dalen, Havard

    2016-01-01

    Objectives Medical history, physical examination and laboratory testing are not optimal for the assessment of volume status in heart failure (HF) patients. We aimed to study the clinical influence of focused ultrasound of the pleural cavities and inferior vena cava (IVC) performed by specialised nurses to assess volume status in HF patients at an outpatient clinic. Methods HF outpatients were prospectively included and underwent laboratory testing, history recording and clinical examination by two nurses with and without an ultrasound examination of the pleural cavities and IVC using a pocket-size imaging device, in random order. Each nurse worked in a team with a cardiologist. The influence of the different diagnostic tests on diuretic dosing was assessed descriptively and in linear regression analyses. Results Sixty-two patients were included and 119 examinations were performed. Mean±SD age was 74±12 years, EF was 34±14%, and N-terminal pro-brain natriuretic peptide (NT-proBNP) value was 3761±3072 ng/L. Dosing of diuretics differed between the teams in 31 out of 119 consultations. Weight change and volume status assessed clinically with and without ultrasound predicted dose adjustment of diuretics at follow-up (p<0.05). Change of oedema, NT-proBNP, creatinine, and symptoms did not (p≥0.10). In adjusted analyses, only volume status based on ultrasound predicted dose adjustments of diuretics at first visit and follow-up (all ultrasound p≤0.01, all other p≥0.2). Conclusions Ultrasound examinations of the pleural cavities and IVC by nurses may improve diagnostics and patient care in HF patients at an outpatient clinic, but more studies are needed to determine whether these examinations have an impact on clinical outcomes. Trial registration number NCT01794715. PMID:26438785

  17. Adding point of care ultrasound to assess volume status in heart failure patients in a nurse-led outpatient clinic. A randomised study.

    PubMed

    Gundersen, Guri Holmen; Norekval, Tone M; Haug, Hilde Haugberg; Skjetne, Kyrre; Kleinau, Jens Olaf; Graven, Torbjorn; Dalen, Havard

    2016-01-01

    Medical history, physical examination and laboratory testing are not optimal for the assessment of volume status in heart failure (HF) patients. We aimed to study the clinical influence of focused ultrasound of the pleural cavities and inferior vena cava (IVC) performed by specialised nurses to assess volume status in HF patients at an outpatient clinic. HF outpatients were prospectively included and underwent laboratory testing, history recording and clinical examination by two nurses with and without an ultrasound examination of the pleural cavities and IVC using a pocket-size imaging device, in random order. Each nurse worked in a team with a cardiologist. The influence of the different diagnostic tests on diuretic dosing was assessed descriptively and in linear regression analyses. Sixty-two patients were included and 119 examinations were performed. Mean±SD age was 74±12 years, EF was 34±14%, and N-terminal pro-brain natriuretic peptide (NT-proBNP) value was 3761±3072 ng/L. Dosing of diuretics differed between the teams in 31 out of 119 consultations. Weight change and volume status assessed clinically with and without ultrasound predicted dose adjustment of diuretics at follow-up (p<0.05). Change of oedema, NT-proBNP, creatinine, and symptoms did not (p≥0.10). In adjusted analyses, only volume status based on ultrasound predicted dose adjustments of diuretics at first visit and follow-up (all ultrasound p≤0.01, all other p≥0.2). Ultrasound examinations of the pleural cavities and IVC by nurses may improve diagnostics and patient care in HF patients at an outpatient clinic, but more studies are needed to determine whether these examinations have an impact on clinical outcomes. NCT01794715. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. [Prevalence of stenosis and thrombosis of central veins in hemodialysis after a tunneled jugular catheter].

    PubMed

    Jean, G; Vanel, T; Chazot, C; Charra, B; Terrat, J C; Hurot, J M

    2001-01-01

    Central venous stenosis (ST) and thrombosis (TB) related to catheter (KT) had been reported mostly for the subclavian vein. We performed a systematic cavographic study to evaluate the prevalence of these complications in 51 hemodialysis patients with present or previous history of tunneled internal jugular catheter. Each of them had used one or several KT (1.8 +/- 1.4 KT) for a mean 28 +/- 26 month cumulative time (i.e. 43,584 days total exposure time). Fifty percent of the KT were PermCath Quinton and 50% were Twincath (uncuffed) or CS 100 (cuffed) Medcomp. Twenty-seven had no ST (53%, group I), 24 had one or several significant ST (47%, group II) of superior Vena Cava (SVC, n = 4), inferior Vena Cava (IVC, n = 1), Brachio-cephalic Vein (BCV, n = 5) and subclavian vein (SC, n = 10), or a TB of SVC (n = 1), IVC (n = 3), BCV (n = 3), SC (n = 2). This accounts for an incidence of 0.55 ST or TB/1000 patient-days. Five of the twelve subclavian ST and TB had no history of previous subclavian catheter. Comparison between the two groups showed no differences according to age, time on dialysis, diabetes, hematocrit, CRP, cumulative time with catheter, catheter-related infections, type of catheter and anticoagulant treatment. IVC catheter tip's position is an important risk factor for TB and ST (4/6). Twelve group II patients had ST or TB-related symptoms, with a functional AV fistula in 9 cases. Eleven patients underwent repeated percutaneous angioplasty with 4 additional Wallstents and in 2 cases an AV fistula need to be closed. Central venous ST and TB after a jugular KT is extremely frequent, mostly without any symptoms. Consequences on peripheral or central vascular access, cost and poor long-term patency rate of angioplasty are of major importance. These results incite us to further reduce the catheter use in dialysis patients.

  19. Gunther Tulip Retrievable Inferior Vena Caval Filters: Indications, Efficacy, Retrieval, and Complications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Looby, S.; Given, M.F.; Geoghegan, T.

    Purpose. We evaluated the Gunther Tulip (GT) retrievable inferior vena cava (IVC) filter with regard to indications, filtration efficacy, complications, retrieval window, and use of anticoagulation. Method. A retrospective study was performed of 147 patients (64 men, 83 women; mean age 58.8 years) who underwent retrievable GT filter insertion between 2001 and 2005. The indications for placement included a diagnosis of pulmonary embolism or deep venous thrombosis with a contraindication to anticoagulation (n = 68), pulmonary embolism or deep venous thrombosis while on anticoagulation (n = 49), prophylactic filter placement for high-risk surgical patients with a past history of pulmonarymore » embolism or deep venous thrombosis (n = 20), and a high risk of pulmonary embolism or deep venous thrombosis (n = 10). Forty-nine of the 147 patients did not receive anticoagulation (33.7%) while 96 of 147 patients did, 82 of these receiving warfarin (56.5%), 11 receiving low-molecular weight heparins (7.58%), and 3 receiving antiplatelet agents alone (2.06%). Results. Filter placement was successful in 147 patients (100%). Two patients had two filters inserted. Of the 147 patients, filter deployment was on a permanent basis in 102 and with an intention to retrieve in 45 patients. There were 36 (80%) successful retrievals and 9 (20%) failed retrievals. The mean time to retrieval was 33.6 days. The reasons for failed retrieval included filter struts tightly adherent to the IVC wall (5/9), extreme filter tilt (2/9), and extensive filter thrombus (2/9). Complications included pneumothorax (n = 4), failure of filter expansion (n = 1), and breakthrough pulmonary embolism (n = 1). No IVC thrombotic episodes were recorded. Discussion. The Gunther Tulip retrievable filter can be used as a permanent or a retrievable filter. It is safe and efficacious. GT filters can be safely retrieved at a mean time interval of 33.6 days. The newly developed Celect filter may extend the retrieval interval.« less

  20. Post-Earthquake Assessment of Nevada Bridges Using ShakeMap/ShakeCast

    DOT National Transportation Integrated Search

    2016-01-01

    Post-earthquake capacity of Nevada highway bridges is examined through a combination of engineering study and scenario earthquake evaluation. The study was undertaken by the University of Nevada Reno Department of Civil and Environmental Engineering ...

  1. 11. EASTERN EDGE OF POST ENGINEER'S SHOPS AND YARD BUILDINGS, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. EASTERN EDGE OF POST ENGINEER'S SHOPS AND YARD BUILDINGS, WITH BUILDING 283 ON RIGHT, LOOKING 186 DEGREES SOUTH. - Presidio of San Francisco, Warehouse & Auto Shop, Crissy Field North cantonment, San Francisco, San Francisco County, CA

  2. Effect of post injections on mixture preparation and unburned hydrocarbon emissions in a heavy-duty diesel engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Connor, Jacqueline; Musculus, Mark P. B.; Pickett, Lyle M.

    This work explores the mechanisms by which a post injection can reduce unburned hydrocarbon (UHC) emissions in heavy-duty diesel engines operating at low-temperature combustion conditions. Post injections, small, close-coupled injections of fuel after the main injection, have been shown to reduce UHC in the authors’ previous work. In this work, we analyze optical data from laser-induced fluorescence of both CH 2O and OH and use chemical reactor modeling to better understand the mechanism by which post injections reduce UHC emissions. The results indicate that post-injection efficacy, or the extent to which a post injection reduces UHC emissions, is a strongmore » function of the cylinder pressure variation during the post injection. However, the data and analysis indicate that the pressure and temperature rise from the post injection combustion cannot solely explain the UHC reduction measured by both engine-out and optical diagnostics. In conclusion, the fluid-mechanic, thermal, and chemical interaction of the post injection with the main-injection mixture is a key part of UHC reduction; the starting action of the post jet and the subsequent entrainment of surrounding gases are likely both important processes in reducing UHC with a post injection.« less

  3. Effect of post injections on mixture preparation and unburned hydrocarbon emissions in a heavy-duty diesel engine

    DOE PAGES

    O'Connor, Jacqueline; Musculus, Mark P. B.; Pickett, Lyle M.

    2016-05-30

    This work explores the mechanisms by which a post injection can reduce unburned hydrocarbon (UHC) emissions in heavy-duty diesel engines operating at low-temperature combustion conditions. Post injections, small, close-coupled injections of fuel after the main injection, have been shown to reduce UHC in the authors’ previous work. In this work, we analyze optical data from laser-induced fluorescence of both CH 2O and OH and use chemical reactor modeling to better understand the mechanism by which post injections reduce UHC emissions. The results indicate that post-injection efficacy, or the extent to which a post injection reduces UHC emissions, is a strongmore » function of the cylinder pressure variation during the post injection. However, the data and analysis indicate that the pressure and temperature rise from the post injection combustion cannot solely explain the UHC reduction measured by both engine-out and optical diagnostics. In conclusion, the fluid-mechanic, thermal, and chemical interaction of the post injection with the main-injection mixture is a key part of UHC reduction; the starting action of the post jet and the subsequent entrainment of surrounding gases are likely both important processes in reducing UHC with a post injection.« less

  4. 28. Photographic copy of the Post Engineer drawing (original is ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    28. Photographic copy of the Post Engineer drawing (original is located at Fort Hood) building section & wall sections, plan number PE 1264.1 - Fort Hood, World War II Temporary Buildings, Cold Storage Building, Seventeenth Street, Killeen, Bell County, TX

  5. 31. Photographic copy of the Post Engineer drawing (original is ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. Photographic copy of the Post Engineer drawing (original is located at Fort Hood) concrete dock details, plan number PE 1265.1 - Fort Hood, World War II Temporary Buildings, Cold Storage Building, Seventeenth Street, Killeen, Bell County, TX

  6. 34. Photographic copy of the Post Engineer drawing (original is ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. Photographic copy of the Post Engineer drawing (original is located at Fort Hood) electrical riser plan, plan number PE 1268.2 - Fort Hood, World War II Temporary Buildings, Cold Storage Building, Seventeenth Street, Killeen, Bell County, TX

  7. 29. Photographic copy of the Post Engineer drawing (original is ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. Photographic copy of the Post Engineer drawing (original is located at Fort Hood) building section & details, plan number PE 1264.2 - Fort Hood, World War II Temporary Buildings, Cold Storage Building, Seventeenth Street, Killeen, Bell County, TX

  8. Validating a Fidelity Scale to Understand Intervention Effects in Classroom-Based Studies

    ERIC Educational Resources Information Center

    Buckley, Pamela; Moore, Brooke; Boardman, Alison G.; Arya, Diana J.; Maul, Andrew

    2017-01-01

    K-12 intervention studies often include fidelity of implementation (FOI) as a mediating variable, though most do not report the validity of fidelity measures. This article discusses the critical need for validated FOI scales. To illustrate our point, we describe the development and validation of the Implementation Validity Checklist (IVC-R), an…

  9. Project MET. A Trainer's Guide. Management for Effective Teaching, A Title IV-C Project.

    ERIC Educational Resources Information Center

    Fairfax County Public Schools, VA. Dept. of Instructional Services.

    This guide provides trainers with a format and process for conducting inservice education programs for elementary school teachers on the use of the Management for Effective Teaching (MET) support kit. Project MET is a program developed to aid teachers in the Fairfax County (Virginia) public schools in implementing the school district curriculum,…

  10. Imperial Valley College 2+2+2 Project Handbook.

    ERIC Educational Resources Information Center

    Marquez, Ralph

    This handbook of the Imperial Valley College (IVC) 2+2+2 Project provides an overview of the development of an articulated education program for business and law enforcement careers, involving six local high schools and San Diego State University, Imperial Valley Campus. Following a brief introduction to the 2+2+2 project in section I, section II…

  11. Aldesleukin and Pembrolizumab in Treating Patients With Stage III-IV Melanoma

    ClinicalTrials.gov

    2018-05-23

    Metastatic Melanoma; Stage III Mucosal Melanoma of the Head and Neck; Stage IIIA Skin Melanoma; Stage IIIB Skin Melanoma; Stage IIIC Skin Melanoma; Stage IV Skin Melanoma; Stage IVA Mucosal Melanoma of the Head and Neck; Stage IVB Mucosal Melanoma of the Head and Neck; Stage IVC Mucosal Melanoma of the Head and Neck

  12. 33. Photographic copy of the Post Engineer drawing (original is ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. Photographic copy of the Post Engineer drawing (original is located at Fort Hood) electric plan & light fixture schedule, plan number PE 1268.1 - Fort Hood, World War II Temporary Buildings, Cold Storage Building, Seventeenth Street, Killeen, Bell County, TX

  13. 21. Post Engineer Office, Presidio of San Francisco, Letterman Army ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. Post Engineer Office, Presidio of San Francisco, Letterman Army Hospital. EKG Cardiology Clinic, Building 1049. December 1955. BUILDING 1049. - Presidio of San Francisco, Letterman General Hospital, Building No. 12, Letterman Hospital Complex, Edie Road, San Francisco, San Francisco County, CA

  14. 32. Photographic copy of the Post Engineer drawing (original is ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    32. Photographic copy of the Post Engineer drawing (original is located at Fort Hood) compressor, evaporative condenser & unit cooler schedules, plan number PE 1268 - Fort Hood, World War II Temporary Buildings, Cold Storage Building, Seventeenth Street, Killeen, Bell County, TX

  15. Heavy-Duty Low-Temperature and Diesel Combustion & Heavy-Duty Combustion Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Musculus, Mark P.

    Regulatory drivers and market demands for lower pollutant emissions, lower carbon dioxide emissions, and lower fuel consumption motivate the development of clean and fuel-efficient engine operating strategies. Most current production engines use a combination of both in-cylinder and exhaust emissions-control strategies to achieve these goals. The emissions and efficiency performance of in-cylinder strategies depend strongly on flow and mixing processes associated with fuel injection. Various diesel engine manufacturers have adopted close-coupled post-injection combustion strategies to both reduce pollutant emissions and to increase engine efficiency for heavy-duty applications, as well as for light- and medium-duty applications. Close-coupled post-injections are typically shortmore » injections that follow a larger main injection in the same cycle after a short dwell, such that the energy conversion efficiency of the post-injection is typical of diesel combustion. Of the various post-injection schedules that have been reported in the literature, effects on exhaust soot vary by roughly an order of magnitude in either direction of increasing or decreasing emissions relative to single injections (O’Connor et al., 2015). While several hypotheses have been offered in the literature to help explain these observations, no clear consensus has been established. For new engines to take full advantage of the benefits that post-injections can offer, the in-cylinder mechanisms that affect emissions and efficiency must be identified and described to provide guidance for engine design.« less

  16. Fabric Structures Team Technology Update

    DTIC Science & Technology

    2011-11-01

    Command Posts – • Julia McAdams – Chemical Engineer • Liz Swisher – Electrical Engineer • Chris Aall – Mechanical Engineer • Clinton McAdams...TEMPER design originally built for AMED through Force Provider (640 sq ft with a 20 ft long airlock) • The entire airlock is made of textiles and...Activity (USAMMDA) UNCLASSIFIED Large Command Post Airbeam Shelter NSRDEC Deployment – Sept 2011 UNCLASSIFIED Airbeam & Frame Backpackable Tents • Primary

  17. 22. Post Engineer Office, Presidio of San Francisco, Building # ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. Post Engineer Office, Presidio of San Francisco, Building # 1049 Letterman General Hospital. Alterations to EKG Cardiology Clinic. November 1963. BUILDING 1049. - Presidio of San Francisco, Letterman General Hospital, Building No. 12, Letterman Hospital Complex, Edie Road, San Francisco, San Francisco County, CA

  18. Ohio Engineering Technologies Competency Profile.

    ERIC Educational Resources Information Center

    Miller, Lavonna; Draeger, Meg; Bowermeister, Bob; Wancho, Richard

    This document, which lists engineering technologies competencies as identified by representatives from business and industry as well as secondary and post-secondary educators throughout Ohio, is intended to assist individuals and organizations in developing college tech prep programs that will prepare students from secondary through post-secondary…

  19. Structural dynamic analysis of the Space Shuttle Main Engine

    NASA Technical Reports Server (NTRS)

    Scott, L. P.; Jamison, G. T.; Mccutcheon, W. A.; Price, J. M.

    1981-01-01

    This structural dynamic analysis supports development of the SSME by evaluating components subjected to critical dynamic loads, identifying significant parameters, and evaluating solution methods. Engine operating parameters at both rated and full power levels are considered. Detailed structural dynamic analyses of operationally critical and life limited components support the assessment of engine design modifications and environmental changes. Engine system test results are utilized to verify analytic model simulations. The SSME main chamber injector assembly is an assembly of 600 injector elements which are called LOX posts. The overall LOX post analysis procedure is shown.

  20. Aerospike Engine Post-Test Diagnostic System Delivered to Rocketdyne

    NASA Technical Reports Server (NTRS)

    Meyer, Claudia M.

    2000-01-01

    The NASA Glenn Research Center at Lewis Field, in cooperation with Rocketdyne, has designed, developed, and implemented an automated Post-Test Diagnostic System (PTDS) for the X-33 linear aerospike engine. The PTDS was developed to reduce analysis time and to increase the accuracy and repeatability of rocket engine ground test fire and flight data analysis. This diagnostic system provides a fast, consistent, first-pass data analysis, thereby aiding engineers who are responsible for detecting and diagnosing engine anomalies from sensor data. It uses analytical methods modeled after the analysis strategies used by engineers. Glenn delivered the first version of PTDS in September of 1998 to support testing of the engine s power pack assembly. The system was used to analyze all 17 power pack tests and assisted Rocketdyne engineers in troubleshooting both data acquisition and test article anomalies. The engine version of PTDS, which was delivered in June of 1999, will support all single-engine, dual-engine, and flight firings of the aerospike engine.

  1. 78 FR 48233 - Medicare Program; FY 2014 Hospice Wage Index and Payment Rate Update; Hospice Quality Reporting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-07

    ... Contents I. Executive Summary A. Purpose B. Summary of the Major Provisions C. Summary of Costs, Benefits, and Transfers II. Background A. Hospice Care B. History of the Medicare Hospice Benefit C. Services... IV.C.3. We also update the FY 2014 hospice wage index with more current wage data, and the BNAF will...

  2. Environmental Assessment for the Space Complex-5 SCOUT Launcher Relocation, Vandenberg Air Force Base, California

    DTIC Science & Technology

    2009-01-01

    Agreement (L,nderJ) ;ng PA) stipu atmg thaI Cold War propertIes significant for their distir.c:ivc physical characteristics and ~hclr historic function...launch complex th t dir Iy upported ooerational missions 0 the exceptionally imp rtant Cold War program. n You l1ave aiso submi tea a map that outlines

  3. Using Set Model for Learning Addition of Integers

    ERIC Educational Resources Information Center

    Lestari, Umi Puji; Putri, Ratu Ilma Indra; Hartono, Yusuf

    2015-01-01

    This study aims to investigate how set model can help students' understanding of addition of integers in fourth grade. The study has been carried out to 23 students and a teacher of IVC SD Iba Palembang in January 2015. This study is a design research that also promotes PMRI as the underlying design context and activity. Results showed that the…

  4. 77 FR 67360 - Igiugig Village Council; Notice of Successive Preliminary Permit Application Accepted for Filing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-09

    ... an application for a successive preliminary permit, pursuant to section 4(f) of the Federal Power Act, proposing to study the feasibility of the Igiugig RISEC Water Power Project (Igiugig Project or project), to... proposed transmission line that will either connect directly to the IVC diesel power plant or a 1,000-foot...

  5. Laminar and regional distribution of galanin binding sites in cat and monkey visual cortex determined by in vitro receptor autoradiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosier, A.M.; Vandesande, F.; Orban, G.A.

    1991-03-08

    The distribution of galanin (GAL) binding sites in the visual cortex of cat and monkey was determined by autoradiographic visualization of ({sup 125}I)-GAL binding to tissue sections. Binding conditions were optimized and, as a result, the binding was saturable and specific. In cat visual cortex, GAL binding sites were concentrated in layers I, IVc, V, and VI. Areas 17, 18, and 19 exhibited a similar distribution pattern. In monkey primary visual cortex, the highest density of GAL binding sites was observed in layers II/III, lower IVc, and upper V. Layers IVA and VI contained moderate numbers of GAL binding sites,more » while layer I and the remaining parts of layer IV displayed the lowest density. In monkey secondary visual cortex, GAL binding sites were mainly concentrated in layers V-VI. Layer IV exhibited a moderate density, while the supragranular layers contained the lowest proportion of GAL binding sites. In both cat and monkey, we found little difference between regions subserving central and those subserving peripheral vision. Similarities in the distribution of GAL and acetylcholine binding sites are discussed.« less

  6. A review of the anatomy and clinical significance of adrenal veins.

    PubMed

    Cesmebasi, Alper; Du Plessis, Maira; Iannatuono, Mark; Shah, Sameer; Tubbs, R Shane; Loukas, Marios

    2014-11-01

    The adrenal veins may present with a multitude of anatomical variants, which surgeons must be aware of when performing adrenalectomies. The adrenal veins originate during the formation of the prerenal inferior vena cava (IVC) and are remnants of the caudal portion of the subcardinal veins, cranial to the subcardinal sinus in the embryo. The many communications between the posterior cardinal, supracardinal, and subcardinal veins of the primordial venous system provide an explanation for the variable anatomy. Most commonly, one central vein drains each adrenal gland. The long left adrenal vein joins the inferior phrenic vein and drains into the left renal vein, while the short right adrenal vein drains immediately into the IVC. Multiple variations exist bilaterally and may pose the risk of surgical complications. Due to the potential for collaterals and accessory adrenal vessels, great caution must be taken during an adrenalectomy. Adrenal venous sampling, the gold standard in diagnosing primary hyperaldosteronism, also requires the clinician to have a thorough knowledge of the adrenal vein anatomy to avoid iatrogenic injury. The adrenal vein acts as an important conduit in portosystemic shunts, thus the nature of the anatomy and hypercoagulable states pose the risk of thrombosis. © 2014 Wiley Periodicals, Inc.

  7. Calcium-sensing receptor (CASR) is involved in porcine in vitro fertilisation and early embryo development.

    PubMed

    Liu, C; Liu, Y; Larsen, K; Hou, Y P; Callesen, H

    2018-01-01

    It has been demonstrated that extracellular calcium is necessary in fertilisation and embryo development but the mechanism is still not well understood. The present study mainly focussed on the extracellular calcium effector called the calcium-sensing receptor (CASR) and examined its expression in porcine gametes and embryos and its function during fertilisation and early embryo development. By using reverse transcription polymerase chain reaction, CASR was found to be expressed in porcine oocytes, spermatozoa and embryos at different developmental stages. Functionally, medium supplementation with a CASR agonist or an antagonist during in vitro fertilisation (IVF) and in vitro culture (IVC) was tested. During fertilisation, the presence of a CASR agonist increased sperm penetration rate and decreased polyspermy rate leading to an increased normal fertilisation rate. During embryo development, for the IVF embryos, agonist treatment during IVC significantly increased cleavage rate and blastocyst formation rate compared with the control group. Furthermore, parthenogenetically activated embryos showed similar results with lower cleavage and blastocyst formation rates in the antagonist group than in the other groups. It was concluded that CASR, as the effector of extracellular calcium, modulates porcine fertilisation and early embryo development.

  8. ETR BUILDING, TRA642, INTERIOR. BASEMENT. ROLLUP DOOR TO CUBICLE POSTS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ETR BUILDING, TRA-642, INTERIOR. BASEMENT. ROLLUP DOOR TO CUBICLE POSTS CAUTION SIGNS BECAUSE OF SODIUM HAZARD WITHIN. INL NEGATIVE NO. HD24-3-1. Mike Crane, Photographer, 11/2000 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  9. Conversion of the Defense Communications System from Analog to Digital Form.

    DTIC Science & Technology

    1974-06-01

    Hjr,.nZing of Mail: Transmission Methods, Report R-69-046-5, Prepared for Bureau of Research and Engineering, Post Office Department, Washington (July...Transmission Methods, Report R-69-046-5, Prepared for Bureau of Research and 165 Engineerin-, Post Office Department, Washington (July 1970), P. 3-5. 3...Prepared for Bureau of Research and Engineering, Post Office Department Washington . July 1970. Df-AG" 5M ARMY COMMAND AND SENERAL STAFF COLL FORT

  10. Quantitative Ultrasound for Nondestructive Characterization of Engineered Tissues and Biomaterials

    PubMed Central

    Dalecki, Diane; Mercado, Karla P.; Hocking, Denise C.

    2015-01-01

    Non-invasive, non-destructive technologies for imaging and quantitatively monitoring the development of artificial tissues are critical for the advancement of tissue engineering. Current standard techniques for evaluating engineered tissues, including histology, biochemical assays and mechanical testing, are destructive approaches. Ultrasound is emerging as a valuable tool for imaging and quantitatively monitoring the properties of engineered tissues and biomaterials longitudinally during fabrication and post-implantation. Ultrasound techniques are rapid, non-invasive, non-destructive and can be easily integrated into sterile environments necessary for tissue engineering. Furthermore, high-frequency quantitative ultrasound techniques can enable volumetric characterization of the structural, biological, and mechanical properties of engineered tissues during fabrication and post-implantation. This review provides an overview of ultrasound imaging, quantitative ultrasound techniques, and elastography, with representative examples of applications of these ultrasound-based techniques to the field of tissue engineering. PMID:26581347

  11. Interactive Videoconferencing for Collaborative Learning at a Distance in the School of 21st Century: A Case Study in Elementary Schools in Greece

    ERIC Educational Resources Information Center

    Anastasiades, Panagiotes S.; Filippousis, George; Karvunis, Labros; Siakas, Spiros; Tomazinakis, Arsitokritos; Giza, Panagiota; Mastoraki, Hellen

    2010-01-01

    The aim of this paper is to present the design, implementation and evaluation of the methodology which focuses on the pedagogical utilization of Interactive Videoconferencing (IVC) in the contemporary elementary school. As part of the project "ODYSSEAS", during the school year 2007-2008, 46 students and 4 teachers from two elementary…

  12. A Curriculum Guide to the 1979-80 Challenge Grant Projects of the Comprehensive Arts Program (Title IV-C).

    ERIC Educational Resources Information Center

    Sturtz, Shirley, Ed.; Ramsey, Jonny H., Ed.

    This publication contains summary descriptions of the 33 grant proposals in the arts which teachers in Intermediate Unit No. 10 in Harrisburg, Pennsylvania, submitted to the Challenge Grant Program. The purpose of the Program during 1979-80 was to provide grants to public and nonpublic school staff to encourage and assist them in planning and…

  13. Advanced Technologies in Trauma Critical Care Management

    DTIC Science & Technology

    2012-01-01

    CVL, central venous line; DVT, deep venous thrombosis; FAST, focused assessment with sonography for trauma; IVC, inferior vena cava; PIV, peripheral...either for a 1-time view of the target vein or in real time using a 1- or 2-person technique. Recently, ultrasound-guided subclavian central venous ...technologies such as bedside echocardiography, central venous pressure monitoring, and cardiac electrical velocimetry. These limitations aside, it is

  14. A Nutrition Education Bibliography for Teachers of All Subjects and Grade Levels. Revised Edition, 1978. Developed through an ESEA Title IVC Project in Nutrition Education for Schools.

    ERIC Educational Resources Information Center

    Luzerne Intermediate Unit 18, Kingston, PA.

    This bibliography lists a library collection of educational resources on topics in nutrition which are available to elementary and secondary teachers who need information and instructional aids to help them implement nutrition education into the existing curriculum. Two hundred seven entries of nutrition education resources comprise this…

  15. Bird's Nest Filter Causing Symptomatic Hydronephrosis Following Transmural Penetration of the Inferior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stacey, C.S., E-mail: cheika@doctors.org.uk; Manhire, A.R.; Rose, D.H.

    2004-01-15

    We report a case of symptomatic hydronephrosis caused by transcaval penetration of a Bird's Nest filter. Perforation of the wall of the inferior vena cava (IVC) following insertion of a caval filter is a well-recognized complication. Whilst two cases of hydronephrosis have been described with Greenfield filters, no case involving a Bird's Nest filter has been reported previously.

  16. I "Still" Wanna Be an Engineer! Women, Education and the Engineering Profession

    ERIC Educational Resources Information Center

    Gill, Judith; Sharp, Rhonda; Mills, Julie; Franzway, Suzanne

    2008-01-01

    Women's low enrolment in post-school engineering degrees continues to be a problem for engineering faculties and the profession generally. A qualitative interview-based study of Australian women engineers across the range of engineering disciplines showed the relevance of success in math and science at school to their enrolling in engineering at…

  17. Early MRI Detection and Closed Bone Graft Epiphysiodesis May Alter the Course of Avascular Necrosis Following Unstable Slipped Capital Femoral Epiphysis.

    PubMed

    Napora, Joshua K; Gilmore, Allison; Son-Hing, Jochen P; Grimberg, Dominic C; Thompson, George H; Liu, Raymond W

    2018-04-01

    Unstable slipped capital femoral epiphysis (SCFE) has an increased incidence of avascular necrosis (AVN). Early identification and surgical intervention for AVN may help preserve the femoral head. We retrospectively reviewed 48 patients (50 hips) with unstable SCFE managed between 2000 and 2014. AVN was diagnosed based on 2 different postoperative protocols. Seventeen patients (17 hips) had a scheduled magnetic resonance imaging (MRI) between 1 and 6 months from initial surgery, and the remaining 31 patients (33 hips) were evaluated by plain radiographs alone. If AVN was diagnosed, we offered core decompression and closed bone graft epiphysiodesis (CBGE) to mitigate its affects. At final follow-up, we assessed progression of AVN using the Steinberg classification. Overall 13 hips (26%) with unstable SCFEs developed AVN. MRI revealed AVN in 7 of 17 hips (41%) at a mean of 2.5 months postoperatively (range, 1.0 to 5.2 mo). Six hips diagnosed by MRI received surgical intervention (4 CBGE, 1 free vascularized fibula graft, and 1 repinning due to screw cutout) at a mean of 4.1 months (range, 1.3 to 7.2 mo) postoperatively. None of the 4 patients treated with CBGE within 2 months postoperatively progressed to stage IVC AVN. The 2 patients treated after 4 months postoperatively both progressed to stage VC AVN.Plain radiographs demonstrated AVN in 6 of 33 hips (18%) at a mean of 6.8 months postoperatively (range, 2.1 to 21.1 mo). One patient diagnosed with stage IVB AVN at 2.4 months had screw cutout and received CBGE at 2.5 months from initial pinning. The remaining 5 were not offered surgical intervention. Five of the 6 radiographically diagnosed AVN, including the 1 treated with CBGE, progressed to stage IVC AVN or greater. Although all patients with positive MRI scans developed radiographic AVN, none of the 4 patients treated with CBGE within 2 months after pinning developed grade IVC or greater AVN. Early MRI detection and CBGE may mitigate the effects of AVN after SCFE. Level III-retrospective comparative study.

  18. Infusion System Architecture Impacts the Ability of Intensive Care Nurses to Maintain Hemodynamic Stability in a Living Swine Simulator.

    PubMed

    Pezone, Matthew J; Peterfreund, Robert A; Maslov, Mikhail Y; Govindaswamy, Radhika R; Lovich, Mark A

    2016-05-01

    The authors have previously shown that drug infusion systems with large common volumes exhibit long delays in reaching steady-state drug delivery and pharmacodynamic effects compared with smaller common-volume systems. The authors hypothesized that such delays can impede the pharmacologic restoration of hemodynamic stability. The authors created a living swine simulator of hemodynamic instability in which occlusion balloons in the aorta and inferior vena cava (IVC) were used to manipulate blood pressure. Experienced intensive care unit nurses blinded to the use of small or large common-volume infusion systems were instructed to maintain mean arterial blood pressure between 70 and 90 mmHg using only sodium nitroprusside and norepinephrine infusions. Four conditions (IVC or aortic occlusions and small or large common volume) were tested 12 times in eight animals. After aortic occlusion, the time to restore mean arterial pressure to range (t1: 2.4 ± 1.4 vs. 5.0 ± 2.3 min, P = 0.003, average ± SD), time-out-of-range (tOR: 6.2 ± 3.5 vs. 9.5 ± 3.4 min, P = 0.028), and area-out-of-range (pressure-time integral: 84 ± 47 vs. 170 ± 100 mmHg · min, P = 0.018) were all lower with smaller common volumes. After IVC occlusion, t1 (3.7 ± 2.2 vs. 7.1 ± 2.6 min, P = 0.002), tOR (6.3 ± 3.5 vs. 11 ± 3.0 min, P = 0.007), and area-out-of-range (110 ± 93 vs. 270 ± 140 mmHg · min, P = 0.003) were all lower with smaller common volumes. Common-volume size did not impact the total amount infused of either drug. Nurses did not respond as effectively to hemodynamic instability when drugs flowed through large common-volume infusion systems. These findings suggest that drug infusion system common volume may have clinical impact, should be minimized to the greatest extent possible, and warrants clinical investigations.

  19. Utility of Retrievable Inferior Vena Cava Filters: A Systematic Literature Review and Analysis of the Reasons for Nonretrieval of Filters with Temporary Indications.

    PubMed

    Jia, Zhongzhi; Fuller, Tyler A; McKinney, J Mark; Paz-Fumagalli, Ricardo; Frey, Gregory T; Sella, David M; Van Ha, Thuong; Wang, Weiping

    2018-05-01

    To investigate the use of retrievable inferior vena cava (IVC) filters in the current practice and analyze the causes of filter left in situ despite initial plans for retrieval. A systematic search of all English-language studies of retrievable IVC filters was conducted, including clinical trials and observational studies published between January 1984 and March 2016. A total of 103 studies were identified, including 10 filter models in 20,319 patients. Placement indications were reported for 11,128 (54.8%) patients, including therapeutic (n = 6270; 56.3%) and prophylactic (n = 4858; 43.7%) indications. A total of 13,224 (65.1%) filters were left as permanent devices; 7095 (34.9%) filters were removed. The reasons for filter nonretrieval among the 5308 (40.1%) reported cases were primary permanent indication (21.2%; 1127/5308), death (19.4%; 1031/5308), ongoing pulmonary embolism (PE) protection (19.0%; 1011/5308), failed retrieval (13.7%; 725/5308), loss to follow-up (13.0%; 689/5308), discontinued care (4.4%; 235/5308), physician oversight (4.0%; 213/5308), patient morbidity (2.8%; 149/5308), and patient refusal (2.4%; 128/5308). A total of 7820 patients presented for filter retrieval, and 7095 filters (90.7%) were successfully removed, with a mean indwelling time of 106.6 ± 47.3 days. Breakthrough PE was reported in 2.1% (191/9169) of patients. Filter tilt, recurrent deep vein thrombosis, penetration, IVC thrombosis, migration, and fracture occurred in 7.7% (798/10,348), 7.1% (362/5092), 5.4% (379/7001), 3.9% (345/8788), 1.4% (160/11,679), and 0.5% (50/9509) of patients, respectively. Approximately two-thirds of retrievable filters were not retrieved even though more than 85% of the filters were initially intended for temporary use. The major reasons for filter left in situ despite initial plans for retrieval were death, need for ongoing PE protection, failed retrieval, loss to follow-up, discontinued care, and physician oversight.

  20. Long-term Outcomes of Percutaneous Venoplasty and Gianturco Stent Placement to Treat Obstruction of the Inferior Vena Cava Complicating Liver Transplantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lorenz, Jonathan M., E-mail: jlorenz@radiology.bsd.uchicago.edu; Beek, Darren van; Funaki, Brian

    PurposeEvaluation of long-term outcomes of venoplasty and Gianturco stents to treat inferior vena cava (IVC) obstruction after liver transplantation.MethodsWe retrospectively analyzed records from 33 consecutive adult patients referred with the intent to treat suspected IVC obstruction after liver transplantation. Treatment was performed for occlusion or stenosis with a gradient exceeding 3 mmHg. The primary treatment was venoplasty and, if refractory, Gianturco stent placement. Recurrence prompted repeat venoplasty or stent placement.ResultsOf the 33 patients, 25 (aged 46.9 ± 12.2 years) required treatment at a mean of 2.3 years (14 days to 20.3 years) after transplantation. For technically successful cases, primary treatment was venoplasty alone (14) or with stentmore » placement (10). Technical success was 96 % (24 of 25) reflecting failure to cross one occlusion. Clinical success was 88 % (22 of 25) reflecting the technical failure and two that died of unrelated complications within 5 weeks. Cumulative primary patencies were 57.1 % at 6 months (n = 21) and 51.4 % at 1 (n = 10), 3 (n = 7), 5 (n = 6), and 7 (n = 5) years. Cumulative primary assisted patency was 95.2 % at 6 months (n = 21) and at 1 (n = 15), 3 (n = 9), 5 (n = 8), and 7 (n = 8) years. The 17 patients stented for refractory (n = 10) or recurrent (n = 7) stenosis had cumulative primary and primary assisted patencies of 86.0 and 100 %, respectively, from 6 months (n = 14) to 7 years (n = 3). No major complications occurred; one fractured stent was observed after 11.6 years.ConclusionFor IVC obstruction following liver transplantation, excellent long-term outcomes can be achieved by venoplasty and Gianturco stent placement.« less

Top