Sample records for post pulse shutter

  1. Post pulse shutter for laser amplifier

    DOEpatents

    Bradley, Laird P. [Livermore, CA; Carder, Bruce M. [Antioch, CA; Gagnon, William L. [Berkeley, CA

    1981-03-17

    Apparatus and method for quickly closing off the return path for an amplified laser pulse at the output of an amplifier so as to prevent damage to amplifiers and other optical components appearing earlier in the chain by the return of an amplified pulse. The apparatus consists of a fast retropulse or post pulse shutter to suppress target reflection and/or beam return. This is accomplished by either quickly placing a solid across the light transmitting aperture of a component in the chain, such as a spatial filter pinhole, or generating and directing a plasma with sufficiently high density across the aperture, so as to, in effect, close the aperture to the returning amplified energy pulse.

  2. Post pulse shutter for laser amplifier

    DOEpatents

    Bradley, L.P.; Carder, B.M.; Gagnon, W.L.

    1981-03-17

    Disclosed are an apparatus and method for quickly closing off the return path for an amplified laser pulse at the output of an amplifier so as to prevent damage to amplifiers and other optical components appearing earlier in the chain by the return of an amplified pulse. The apparatus consists of a fast retropulse or post pulse shutter to suppress target reflection and/or beam return. This is accomplished by either quickly placing a solid across the light transmitting aperture of a component in the chain, such as a spatial filter pinhole, or generating and directing a plasma with sufficiently high density across the aperture, so as to, in effect, close the aperture to the returning amplified energy pulse. 13 figs.

  3. Practical method and device for enhancing pulse contrast ratio for lasers and electron accelerators

    DOEpatents

    Zhang, Shukui; Wilson, Guy

    2014-09-23

    An apparatus and method for enhancing pulse contrast ratios for drive lasers and electron accelerators. The invention comprises a mechanical dual-shutter system wherein the shutters are placed sequentially in series in a laser beam path. Each shutter of the dual shutter system has an individually operated trigger for opening and closing the shutter. As the triggers are operated individually, the delay between opening and closing first shutter and opening and closing the second shutter is variable providing for variable differential time windows and enhancement of pulse contrast ratio.

  4. Single-bunch synchrotron shutter

    DOEpatents

    Norris, James R.; Tang, Jau-Huei; Chen, Lin; Thurnauer, Marion

    1993-01-01

    An apparatus for selecting a single synchrotron pulse from the millions of pulses provided per second from a synchrotron source includes a rotating spindle located in the path of the synchrotron pulses. The spindle has multiple faces of a highly reflective surface, and having a frequency of rotation f. A shutter is spaced from the spindle by a radius r, and has an open position and a closed position. The pulses from the synchrotron are reflected off the spindle to the shutter such that the speed s of the pulses at the shutter is governed by: s=4.times..pi..times.r.times.f. such that a single pulse is selected for transmission through an open position of the shutter.

  5. Subpicosecond pulses from a neodymium-glass laser with a solid-liquid phototropic shutter

    NASA Astrophysics Data System (ADS)

    Altshuler, G. B.; Dulneva, E. G.; Karasev, V. B.; Okishev, A. V.; Telegin, L. S.

    1985-02-01

    Subpicosecond, spectrally limited pulses were generated in a mode-locked silicate-Nd-glass laser by means of a phototropic shutter. The shutter featured molecules of an organic dye added to a matrix composed of an isobutyl alcohol-filled quartz micropore glass plate. A coating on the inner surface of one of the cell windows was 0.99 reflective at the lasing wavelength. Single pulses with 0.5-1 psec length were generated, validating the use of a solid-liquid shutter for producing subpicosecond pulses with a Nd-glass laser. Furthermore, the liquid component permitted output powers of up to 5 W/sq cm without eliciting thermooptical effects.

  6. Synchronization of video recording and laser pulses including background light suppression

    NASA Technical Reports Server (NTRS)

    Kalshoven, Jr., James E. (Inventor); Tierney, Jr., Michael (Inventor); Dabney, Philip W. (Inventor)

    2004-01-01

    An apparatus for and a method of triggering a pulsed light source, in particular a laser light source, for predictable capture of the source by video equipment. A frame synchronization signal is derived from the video signal of a camera to trigger the laser and position the resulting laser light pulse in the appropriate field of the video frame and during the opening of the electronic shutter, if such shutter is included in the camera. Positioning of the laser pulse in the proper video field allows, after recording, for the viewing of the laser light image with a video monitor using the pause mode on a standard cassette-type VCR. This invention also allows for fine positioning of the laser pulse to fall within the electronic shutter opening. For cameras with externally controllable electronic shutters, the invention provides for background light suppression by increasing shutter speed during the frame in which the laser light image is captured. This results in the laser light appearing in one frame in which the background scene is suppressed with the laser light being uneffected, while in all other frames, the shutter speed is slower, allowing for the normal recording of the background scene. This invention also allows for arbitrary (manual or external) triggering of the laser with full video synchronization and background light suppression.

  7. Note: Reliable low-vibration piezo-mechanical shutter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauer, Michael, E-mail: mibauer@physik.uni-kl.de; Franzreb, Philipp Pierre; Widera, Artur

    2014-09-15

    We present a mechanical shutter based on a bending piezo-actuator. The shutter features an active aperture of about 2 mm, allowing for full extinction and lossless transmission of a beam. Acoustic noise and mechanical vibrations produced are very low and the shutter is outstandingly long-lived; a test device has undergone 20 × 10{sup 6} cycles without breaking. A reflector makes the shutter capable of reliably interrupting a beam with at least 2 W of cw power at 780 nm. The shutter is well suited to create pulses as short as 16 ms, while pulse lengths down to 1 ms aremore » possible. The rise and fall times are approximately 120 µs, with a delay of 2 ms. Jitter stays below 10 µs, while long-term drifts stay well below 500 µs.« less

  8. Development of a drive system for a sequential space camera

    NASA Technical Reports Server (NTRS)

    Sharpsteen, J. T.; Solheim, C. D.; Stoap, L. J.

    1976-01-01

    Breadboard models of single and dual motor drives for the shutter, claw and magazine of a space camera system were designed and tested. The single motor technique utilizes a single electronically commutated motor to drive the claw and shutter without resorting to a solenoid actuated clutch for pulse operation. Shutter speed is established by a combination of the cinemode speed and the opening of the conventional DAC two piece shutter. Pulse mode operation is obtained by applying power at a fixed clock rate and removing power at an appropriate point in the mechanical cycle such that the motor comes to rest by system friction. The dual motor approach utilizes a stepper motor to drive the shutter and an electronically commutated dc motor to drive the claw and magazine functions. The motors are synchronized electronically.

  9. Electronic imaging system and technique

    DOEpatents

    Bolstad, J.O.

    1984-06-12

    A method and system for viewing objects obscurred by intense plasmas or flames (such as a welding arc) includes a pulsed light source to illuminate the object, the peak brightness of the light reflected from the object being greater than the brightness of the intense plasma or flame; an electronic image sensor for detecting a pulsed image of the illuminated object, the sensor being operated as a high-speed shutter; and electronic means for synchronizing the shutter operation with the pulsed light source.

  10. Electronic imaging system and technique

    DOEpatents

    Bolstad, Jon O.

    1987-01-01

    A method and system for viewing objects obscurred by intense plasmas or flames (such as a welding arc) includes a pulsed light source to illuminate the object, the peak brightness of the light reflected from the object being greater than the brightness of the intense plasma or flame; an electronic image sensor for detecting a pulsed image of the illuminated object, the sensor being operated as a high-speed shutter; and electronic means for synchronizing the shutter operation with the pulsed light source.

  11. Time-resolved spectroscopy using a chopper wheel as a fast shutter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Shicong; Wendt, Amy E.; Boffard, John B.

    Widely available, small form-factor, fiber-coupled spectrometers typically have a minimum exposure time measured in milliseconds, and thus cannot be used directly for time-resolved measurements at the microsecond level. Spectroscopy at these faster time scales is typically done with an intensified charge coupled device (CCD) system where the image intensifier acts as a “fast” electronic shutter for the slower CCD array. In this paper, we describe simple modifications to a commercially available chopper wheel system to allow it to be used as a “fast” mechanical shutter for gating a fiber-coupled spectrometer to achieve microsecond-scale time-resolved optical measurements of a periodically pulsedmore » light source. With the chopper wheel synchronized to the pulsing of the light source, the time resolution can be set to a small fraction of the pulse period by using a chopper wheel with narrow slots separated by wide spokes. Different methods of synchronizing the chopper wheel and pulsing of the light sources are explored. The capability of the chopper wheel system is illustrated with time-resolved measurements of pulsed plasmas.« less

  12. High speed shutter. [electrically actuated ribbon loop for shuttering optical or fluid passageways

    NASA Technical Reports Server (NTRS)

    Mcclenahan, J. O. (Inventor)

    1974-01-01

    A shutter element is described which is formed by a loop of an electrically conductive ribbon disposed adjacent to the end of a passageway to be shuttered. The shuttered end of the passageway is cut at an acute angle. The two leg portions of the ribbon loop are closely spaced to each other and disposed in a plane parallel to the axis of the passageway. A pulse of high current is switched through the loop to cause the current flowing in opposite directions through adjacent leg portions of the ribbon. This produces a magnetically induced pressure on one of the legs of the ribbon forcing the leg over the end of the passageway in gas tight sealing engagement, and thereby blocking passageway.

  13. DC drive system for cine/pulse cameras

    NASA Technical Reports Server (NTRS)

    Gerlach, R. H.; Sharpsteen, J. T.; Solheim, C. D.; Stoap, L. J.

    1977-01-01

    Camera-drive functions are separated mechanically into two groups which are driven by two separate dc brushless motors. First motor, a 90 deg stepper, drives rotating shutter; second electronically commutated motor drives claw and film transport. Shutter is made of one piece but has two openings for slow and fast exposures.

  14. Method to control deposition rate instabilities—High power impulse magnetron sputtering deposition of TiO{sub 2}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kossoy, Anna, E-mail: annaeden@hi.is, E-mail: anna.kossoy@gmail.com; Magnusson, Rögnvaldur L.; Tryggvason, Tryggvi K.

    2015-03-15

    The authors describe how changes in shutter state (open/closed) affect sputter plasma conditions and stability of the deposition rate of Ti and TiO{sub 2} films. The films were grown by high power impulse magnetron sputtering in pure Ar and in Ar/O{sub 2} mixture from a metallic Ti target. The shutter state was found to have an effect on the pulse waveform for both pure Ar and reactive sputtering of Ti also affecting stability of TiO{sub 2} deposition rate. When the shutter opened, the shape of pulse current changed from rectangular to peak-plateau and pulse energy decreased. The authors attribute itmore » to the change in plasma impedance and gas rarefaction originating in geometry change in front of the magnetron. TiO{sub 2} deposition rate was initially found to be high, 1.45 Å/s, and then dropped by ∼40% during the first 5 min, while for Ti the change was less obvious. Instability of deposition rate poses significant challenge for growing multilayer heterostructures. In this work, the authors suggest a way to overcome this by monitoring the integrated average energy involved in the deposition process. It is possible to calibrate and control the film thickness by monitoring the integrated pulse energy and end growth when desired integrated pulse energy level has been reached.« less

  15. Delayed Shutters For Dual-Beam Molecular Epitaxy

    NASA Technical Reports Server (NTRS)

    Grunthaner, Frank J.; Liu, John L.; Hancock, Bruce

    1989-01-01

    System of shutters for dual-molecular-beam epitaxy apparatus delays start of one beam with respect to another. Used in pulsed-beam equipment for deposition of low-dislocation layers of InAs on GaAs substrates, system delays application of arsenic beam with respect to indium beam to assure proper stoichiometric proportions on newly forming InAs surface. Reflectance high-energy electron diffraction (RHEED) instrument used to monitor condition of evolving surface of deposit. RHEED signal used to time pulsing of molecular beams in way that minimizes density of defects and holds lattice constant of InAs to that of GaAs substrate.

  16. Long-term Stability of the Post-Flash LED Lamp

    NASA Astrophysics Data System (ADS)

    Martlin, Catherine; Baggett, Sylvia

    2017-02-01

    We report the results of a study of the long-term stability of the LED lamp used in post-flashing WFC3/UVIS images. We analyze 644 sub-array exposures taken over the course of just over 3 years and find no significant long-term trends in the LED lamp brightness. The average percentage change per year over all FLASH level and shutter combinations is found to be 0.15% per year with an uncertainty of ± 0.24% per year. The maximum measured percentage change per year was 0.39% for the highest FLASH level of 20 e- on shutter A which would indicate a change of less than 1 e-/pixel over the roughly 3 years since post-flashing began. There are, however, occasional short-term deviations in the LED output. The average minimum and maximum outliers over all FLASH level and shutter combination subsets are 4.1% below and 3.5% above, respectively, the mean of that subset. The maximum outlier over all the sets is 5.8% above the normalized mean value, for FLASH level 3/shutter A. The minimum outlier over all sets is also for FLASH level 3/shutter A and is 8.9% below the normalized mean value. Investigation of these outliers has revealed no systematic cause for the excursions and we recommend that users continue using the post-flash as they would have previously.

  17. Long-term Stability of the WFC3 Post-Flash LED Lamp

    NASA Astrophysics Data System (ADS)

    Martlin, Catherine; Baggett, Sylvia M.

    2017-06-01

    We report the results of a study of the long-term stability of the LED lamp used in post-flashing WFC3/UVIS images (Martlin, C and Baggett, S., 2017). Having analyzed 644 sub-array exposures taken over the course of just over 3 years we find no significant long-term trends in the LED lamp brightness. The average percentage change per year over all FLASH level and shutter combinations is found to be 0.15% per year with an uncertainty of +/- 0.24% per year. The maximum measured percentage change per year was 0.39% for the highest FLASH level of 20 e- on shutter A which would indicate a change of less than 1 e-/pixel over the roughly 3 years since post-flashing began.There are, however, occasional short-term deviations in the LED output. The average minimum and maximum outliers over all FLASH level and shutter combination subsets are 4.1% below and 3.5% above, respectively, the mean of that subset. The maximum outlier over all the sets is 5.8% above the normalized mean value, for FLASH level 3/shutter A. The minimum outlier over all sets is also for FLASH level 3/shutter A and is 8.9% below the normalized mean value. Investigation of these outliers has revealed no systematic cause for the excursions and we recommend that users continue using the post-flash as they would have previously.

  18. Pressure wave charged repetitively pulsed gas laser

    DOEpatents

    Kulkarny, Vijay A.

    1982-01-01

    A repetitively pulsed gas laser in which a system of mechanical shutters bracketing the laser cavity manipulate pressure waves resulting from residual energy in the cavity gas following a lasing event so as to draw fresh gas into the cavity and effectively pump spent gas in a dynamic closed loop.

  19. Apparatus for accurately measuring high temperatures

    DOEpatents

    Smith, D.D.

    The present invention is a thermometer used for measuring furnace temperatures in the range of about 1800/sup 0/ to 2700/sup 0/C. The thermometer comprises a broadband multicolor thermal radiation sensor positioned to be in optical alignment with the end of a blackbody sight tube extending into the furnace. A valve-shutter arrangement is positioned between the radiation sensor and the sight tube and a chamber for containing a charge of high pressure gas is positioned between the valve-shutter arrangement and the radiation sensor. A momentary opening of the valve shutter arrangement allows a pulse of the high gas to purge the sight tube of air-borne thermal radiation contaminants which permits the radiation sensor to accurately measure the thermal radiation emanating from the end of the sight tube.

  20. Apparatus for accurately measuring high temperatures

    DOEpatents

    Smith, Douglas D.

    1985-01-01

    The present invention is a thermometer used for measuring furnace temperaes in the range of about 1800.degree. to 2700.degree. C. The thermometer comprises a broadband multicolor thermal radiation sensor positioned to be in optical alignment with the end of a blackbody sight tube extending into the furnace. A valve-shutter arrangement is positioned between the radiation sensor and the sight tube and a chamber for containing a charge of high pressure gas is positioned between the valve-shutter arrangement and the radiation sensor. A momentary opening of the valve shutter arrangement allows a pulse of the high gas to purge the sight tube of air-borne thermal radiation contaminants which permits the radiation sensor to accurately measure the thermal radiation emanating from the end of the sight tube.

  1. 30-W Yb3+-pulsed fiber laser with wavelength tuning

    NASA Astrophysics Data System (ADS)

    Davydov, B. L.; Krylov, A. A.

    2007-12-01

    We have investigated various pulsed operation regimes of a diode-pumped Yb3+-doped fiber laser with both an acoustooptic filter and a shutter inside the resonator. To imbed the polarization-sensitive acoustooptic-tunable spectral filter into the polarization-nonmaintaining resonator, based on an “isotropic” single-mode fiber without “polarization’ losses, we have used a CaCO3 single-crystal nondispersive thermostable polarization splitter. Stable smooth bell-shaped laser pulses were obtained in the Q-switch generation regime across the entire wavelength tuning band. Their duration depended on the resonator travel time and their repetition rate was determined exclusively by the outer high-frequency generator controlling the acoustooptic shutter. A pulsed laser radiation tuning bandwidth of more than 20-nm at a repetition rate band of 10-100 kHz was observed in the amplification band of the Yb3+-doped fiber. A stable average power of 30 W of the pulsed 70-ns 100-kHz laser radiation in a near Gaussian beam was reached by means of the two-stage amplifier based on Yb3+-doped fibers with an enlarged mode field diameter (14 μm). The amplifier was pumped by λ = 975 nm CW multimode laser diodes with a maximum average power of 42 W.

  2. Investigating MALDI MSI parameters (Part 2) - On the use of a mechanically shuttered trigger system for improved laser energy stability.

    PubMed

    Steven, Rory T; Dexter, Alex; Bunch, Josephine

    2016-07-15

    Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) is now widely used to desorb, ionize and detect molecules from complex samples and tissue sections. The detected ion intensity within MALDI MS and MSI is intimately linked to the laser energy per pulse incident upon the sample during analysis. Laser energy/power stability can be significantly affected by the manner in which the laser is operated. High-repetition rate diode-pumped solid-state (DPSS) lasers are being increasingly adopted to enable high-throughput MALDI MSI analysis. Within this work two different laser-triggering setups are used to demonstrate the effect of laser energy instabilities due to spiking and thermal control phenomena and a setup with a shutter to remove these effects. The effect of non-equilibrium laser operation on MALDI MSI data versus the more stable laser pulse energy of the shutter-triggered system is demonstrated in thin films of α-cyano-4-hydroxycinnamic acid (CHCA) and for imaging of murine brain tissue sections. Significant unwanted variations in absolute and relative detected ion intensity are shown where energy variation is introduced by these phenomena, which return to equilibrium within the setup employed here over timescales relevant to MALDI MS analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Cavitation-based hydro-fracturing technique for geothermal reservoir stimulation

    DOEpatents

    Wang, Jy-An John; Wang, Hong; Ren, Fei; Cox, Thomas S.

    2017-02-21

    A rotary shutter valve 500 is used for geothermal reservoir stimulation. The valve 500 includes a pressure chamber 520 for holding a working fluid (F) under pressure. A rotatable shutter 532 is turned with a powering device 544 to periodically align one or more windows 534 with one or more apertures 526 in a bulkhead 524. When aligned, the pressurized working fluid (F) flows through the bulkhead 524 and enters a pulse cavity 522, where it is discharged from the pulse cavity 522 as pressure waves 200. The pressure wave propagation 200 and eventual collapse of the bubbles 202 can be transmitted to a target rock surface 204 either in the form of a shock wave 206, or by micro jets 208, depending on the bubble-surface distance. Once cavitation at the rock face begins, fractures are initiated in the rock to create a network of micro-fissures for enhanced heat transfer.

  4. High speed photography, videography, and photonics III; Proceedings of the Meeting, San Diego, CA, August 22, 23, 1985

    NASA Technical Reports Server (NTRS)

    Ponseggi, B. G. (Editor); Johnson, H. C. (Editor)

    1985-01-01

    Papers are presented on the picosecond electronic framing camera, photogrammetric techniques using high-speed cineradiography, picosecond semiconductor lasers for characterizing high-speed image shutters, the measurement of dynamic strain by high-speed moire photography, the fast framing camera with independent frame adjustments, design considerations for a data recording system, and nanosecond optical shutters. Consideration is given to boundary-layer transition detectors, holographic imaging, laser holographic interferometry in wind tunnels, heterodyne holographic interferometry, a multispectral video imaging and analysis system, a gated intensified camera, a charge-injection-device profile camera, a gated silicon-intensified-target streak tube and nanosecond-gated photoemissive shutter tubes. Topics discussed include high time-space resolved photography of lasers, time-resolved X-ray spectrographic instrumentation for laser studies, a time-resolving X-ray spectrometer, a femtosecond streak camera, streak tubes and cameras, and a short pulse X-ray diagnostic development facility.

  5. A new 9T global shutter pixel with CDS technique

    NASA Astrophysics Data System (ADS)

    Liu, Yang; Ma, Cheng; Zhou, Quan; Wang, Xinyang

    2015-04-01

    Benefiting from motion blur free, Global shutter pixel is very widely used in the design of CMOS image sensors for high speed applications such as motion vision, scientifically inspection, etc. In global shutter sensors, all pixel signal information needs to be stored in the pixel first and then waiting for readout. For higher frame rate, we need very fast operation of the pixel array. There are basically two ways for the in pixel signal storage, one is in charge domain, such as the one shown in [1], this needs complicated process during the pixel fabrication. The other one is in voltage domain, one example is the one in [2], this pixel is based on the 4T PPD technology and normally the driving of the high capacitive transfer gate limits the speed of the array operation. In this paper we report a new 9T global shutter pixel based on 3-T partially pinned photodiode (PPPD) technology. It incorporates three in-pixel storage capacitors allowing for correlated double sampling (CDS) and pipeline operation of the array (pixel exposure during the readout of the array). Only two control pulses are needed for all the pixels at the end of exposure which allows high speed exposure control.

  6. Laser line scan underwater imaging by complementary metal-oxide-semiconductor camera

    NASA Astrophysics Data System (ADS)

    He, Zhiyi; Luo, Meixing; Song, Xiyu; Wang, Dundong; He, Ning

    2017-12-01

    This work employs the complementary metal-oxide-semiconductor (CMOS) camera to acquire images in a scanning manner for laser line scan (LLS) underwater imaging to alleviate backscatter impact of seawater. Two operating features of the CMOS camera, namely the region of interest (ROI) and rolling shutter, can be utilized to perform image scan without the difficulty of translating the receiver above the target as the traditional LLS imaging systems have. By the dynamically reconfigurable ROI of an industrial CMOS camera, we evenly divided the image into five subareas along the pixel rows and then scanned them by changing the ROI region automatically under the synchronous illumination by the fun beams of the lasers. Another scanning method was explored by the rolling shutter operation of the CMOS camera. The fun beam lasers were turned on/off to illuminate the narrow zones on the target in a good correspondence to the exposure lines during the rolling procedure of the camera's electronic shutter. The frame synchronization between the image scan and the laser beam sweep may be achieved by either the strobe lighting output pulse or the external triggering pulse of the industrial camera. Comparison between the scanning and nonscanning images shows that contrast of the underwater image can be improved by our LLS imaging techniques, with higher stability and feasibility than the mechanically controlled scanning method.

  7. A PC-based shutter glasses controller for visual stimulation using multithreading in LabWindows/CVI.

    PubMed

    Gramatikov, Ivan; Simons, Kurt; Guyton, David; Gramatikov, Boris

    2017-05-01

    Amblyopia, commonly known as "lazy eye," is poor vision in an eye from prolonged neurologic suppression. It is a major public health problem, afflicting up to 3.6% of children, and will lead to lifelong visual impairment if not identified and treated in early childhood. Traditional treatment methods, such as occluding or penalizing the good eye with eye patches or blurring eye drops, do not always yield satisfactory results. Newer methods have emerged, based on liquid crystal shutter glasses that intermittently occlude the better eye, or alternately occlude the two eyes, thus stimulating vision in the "lazy" eye. As yet there is no technology that allows easy and efficient optimization of the shuttering characteristics for a given individual. The purpose of this study was to develop an inexpensive, computer-based system to perform liquid crystal shuttering in laboratory and clinical settings to help "wake up" the suppressed eye in amblyopic patients, and to help optimize the individual shuttering parameters such as wave shape, level of transparency/opacity, frequency, and duty cycle of the shuttering. We developed a liquid crystal glasses controller connected by USB cable to a PC computer. It generates the voltage waveforms going to the glasses, and has potentiometer knobs for interactive adjustments by the patient. In order to achieve good timing performance in this bidirectional system, we used multithreading programming techniques with data protection, implemented in LabWindows/CVI. The hardware and software developed were assessed experimentally. We achieved an accuracy of ±1Hz for the frequency, and ±2% for the duty cycle of the occlusion pulses. We consider these values to be satisfactory for the purpose of optimizing the visual stimulation by means of shutter glasses. The system can be used for individual optimization of shuttering attributes by clinicians, for training sessions in clinical settings, or even at home, aimed at stimulating vision in the "lazy" eye. Multithreading offers significant benefits for data acquisition and instrument control, making it possible to implement time-efficient algorithms in inexpensive yet versatile medical instrumentation with only minimum requirements on the hardware. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Picosecond ballistic imaging of diesel injection in high-temperature and high-pressure air

    NASA Astrophysics Data System (ADS)

    Duran, Sean P.; Porter, Jason M.; Parker, Terence E.

    2015-04-01

    The first successful demonstration of picosecond ballistic imaging using a 15-ps-pulse-duration laser in diesel sprays at temperature and pressure is reported. This technique uses an optical Kerr effect shutter constructed from a CS2 liquid cell and a 15-ps pulse at 532 nm. The optical shutter can be adjusted to produce effective imaging pulses between 7 and 16 ps. This technique is used to image the near-orifice region (first 3 mm) of diesel sprays from a high-pressure single-hole fuel injector. Ballistic imaging of dodecane and methyl oleate sprays injected into ambient air and diesel injection at preignition engine-like conditions are reported. Dodecane was injected into air heated to 600 °C and pressurized to 20 atm. The resulting images of the near-orifice region at these conditions reveal dramatic shedding of the liquid near the nozzle, an effect that has been predicted, but to our knowledge never before imaged. These shedding structures have an approximate spatial frequency of 10 mm-1 with lengths from 50 to 200 μm. Several parameters are explored including injection pressure, liquid fuel temperature, air temperature and pressure, and fuel type. Resulting trends are summarized with accompanying images.

  9. Shutterless ion mobility spectrometer with fast pulsed electron source

    NASA Astrophysics Data System (ADS)

    Bunert, E.; Heptner, A.; Reinecke, T.; Kirk, A. T.; Zimmermann, S.

    2017-02-01

    Ion mobility spectrometers (IMS) are devices for fast and very sensitive trace gas analysis. The measuring principle is based on an initial ionization process of the target analyte. Most IMS employ radioactive electron sources, such as 63Ni or 3H. These radioactive materials have the disadvantage of legal restrictions and the electron emission has a predetermined intensity and cannot be controlled or disabled. In this work, we replaced the 3H source of our IMS with 100 mm drift tube length with our nonradioactive electron source, which generates comparable spectra to the 3H source. An advantage of our emission current controlled nonradioactive electron source is that it can operate in a fast pulsed mode with high electron intensities. By optimizing the geometric parameters and developing fast control electronics, we can achieve very short electron emission pulses for ionization with high intensities and an adjustable pulse width of down to a few nanoseconds. This results in small ion packets at simultaneously high ion densities, which are subsequently separated in the drift tube. Normally, the required small ion packet is generated by a complex ion shutter mechanism. By omitting the additional reaction chamber, the ion packet can be generated directly at the beginning of the drift tube by our pulsed nonradioactive electron source with only slight reduction in resolving power. Thus, the complex and costly shutter mechanism and its electronics can also be omitted, which leads to a simple low-cost IMS-system with a pulsed nonradioactive electron source and a resolving power of 90.

  10. Laser beam delivery at ELI-NP

    DOE PAGES

    Ursescu, Daniel; Cheriaux, G.; Audebert, P.; ...

    2017-01-01

    The Laser Beam Delivery (LBD) system technical design report covers the interface between the High Power Laser System (HPLS) and the experiments, together with the pulse quality management. Here, the laser transport part of the LBD has a number of subsystems as follows: the beam transport lines for the six main outputs of HPLS, the additional short and long pulses and the synchronization system including the timing of the laser pulses with the Gamma Beam System (GBS) and the experiments on femtosecond timescale. Pulse quality management, discussed further here, consist in the generation and delivery of multiple HPLS pulses, coherentmore » combining of the HPLS arms, laser pulse diagnostics on target, laser beam dumps, shutters and output energy adaption.« less

  11. Novel Optical Methods for Identification, Imaging, and Preservation of the Cavernous Nerves Responsible for Penile Erections during Prostate Cancer Surgery

    DTIC Science & Technology

    2009-03-01

    wavelength, pulse energy, and pulse rate) to produce strongest and most rapid erectile response as measured by intracavernosal pressure in the penis ...PC Fiber Rod Housing Optics 5-mm-ID Port Probe Handle Probe Stem Enlarged View of Probe Tip Oscilloscope FunctionGenerator Thulium Fiber Laser Shutter...rapid erectile response as measured by intracavernosal pressure (ICP) in the penis . ICP values were increased from an initial range of 30-40 mmHg

  12. An ultra-fast optical shutter exploiting total light absorption in a phase change material

    NASA Astrophysics Data System (ADS)

    Jafari, Mohsen; Guo, L. Jay; Rais-Zadeh, Mina

    2017-02-01

    In this paper, we present an ultra-fast and high-contrast optical shutter with applications in atomic clock assemblies, integrated photonic systems, communication hardware, etc. The shutter design exploits the total light absorption phenomenon in a thin phase change (PC) material placed over a metal layer. The shutter switches between ON and OFF states by changing PC material phase and thus its refractive index. The PC material used in this work is Germanium Telluride (GeTe), a group IV-VI chalcogenide compound, which exhibits good optical contrast when switching from amorphous to crystalline state and vice versa. The stable phase changing behavior and reliability of GeTe and GeSbTe (GST) have been verified in optical memories and RF switches. Here, GeTe is used as it has a lower extinction coefficient in near-IR regions compared to GST. GeTe can be thermally transitioned between two phases by applying electrical pulses to an integrated heater. The memory behavior of GeTe results in zero static power consumption which is useful in applications requiring long time periods between switching activities. We previously demonstrated a meta-surface employing GeTe in sub-wavelength slits with >14 dB isolation at 1.5 μm by exciting the surface plasmon polariton and localized slit resonances. In this work, strong interference effects in a thin layer of GeTe over a gold mirror result in near total light absorption of up to 40 dB (21 dB measured) in the amorphous phase of the shutter at 780 nm with much less fabrication complexity. The optical loss at the shutter ON state is less than 1.5 dB. A nickel chrome (NiCr) heater provides the Joule heating energy required to achieve the crystallographic phase change. The measured switching speed is 2 μs.

  13. Cerenkov electrooptic shutter

    DOEpatents

    Hartemann, Frederick; Bekefi, George

    1989-05-30

    A system which couples Cerenkov emission with a gated electrooptic effect to allow viewing of Cerenkov radiation in sub nanosecond time-scales is disclosed. Cerenkov radiation is generated by transmitting an electron beam through a transparent medium with a high index of refraction. The Cerenkov radiation is then gated into a sample pulse of subanosecond duration by an electrooptic crystal which has an index of refraction controlled by an electric field. the electrooptic crystal is opaque to the Cerenkov radiation until receiving a 6.0 kV voltage for about 750 picoseconds, upon which a pulsed sample of Cerenkov radiation is transmitted to a display system.

  14. Method and means for generating a synchronizing pulse from a repetitive wave of varying frequency

    DOEpatents

    DeVolpi, Alexander; Pecina, Ronald J.; Travis, Dale J.

    1976-01-01

    An event that occurs repetitively at continuously changing frequencies can be used to generate a triggering pulse which is used to synchronize or control. The triggering pulse is generated at a predetermined percentage of the period of the repetitive waveform without regard to frequency. Counts are accumulated in two counters, the first counting during the "on" fraction of the period, and the second counting during the "off" fraction. The counts accumulated during each cycle are compared. On equality the trigger pulse is generated. Count input rates to each counter are determined by the ratio of the on-off fractions of the event waveform and the desired phase relationship. This invention is of particular utility in providing a trigger or synchronizing pulse during the open period of the shutter of a high-speed framing camera during its acceleration as well as its period of substantially constant speed.

  15. A device for synchronizing biomechanical data with cine film.

    PubMed

    Rome, L C

    1995-03-01

    Biomechanists are faced with two problems in synchronizing continuous physiological data to discrete, frame-based kinematic data from films. First, the accuracy of most synchronization techniques is good only to one frame and hence depends on framing rate. Second, even if perfectly correlated at the beginning of a 'take', the film and physiological data may become progressively desynchronized as the 'take' proceeds. A system is described, which provides synchronization between cine film and continuous physiological data with an accuracy of +/- 0.2 ms, independent of framing rate and the duration of the film 'take'. Shutter pulses from the camera were output to a computer recording system where they were recorded and counted, and to a digital device which counted the pulses and illuminated the count on the bank of LEDs which was filmed with the subject. Synchronization was performed by using the rising edge of the shutter pulse and by comparing the frame number imprinted on the film to the frame number recorded by the computer system. In addition to providing highly accurate synchronization over long film 'takes', this system provides several other advantages. First, having frame numbers imprinted both on the film and computer record greatly facilitates analysis. Second, the LEDs were designed to show the 'take number' while the camera is coming up to speed, thereby avoiding the use of cue cards which disturb the animal. Finally, use of this device results in considerable savings in film.

  16. A fast double shutter for CCD-based metrology

    NASA Astrophysics Data System (ADS)

    Geisler, R.

    2017-02-01

    Image based metrology such as Particle Image Velocimetry (PIV) depends on the comparison of two images of an object taken in fast succession. Cameras for these applications provide the so-called `double shutter' mode: One frame is captured with a short exposure time and in direct succession a second frame with a long exposure time can be recorded. The difference in the exposure times is typically no problem since illumination is provided by a pulsed light source such as a laser and the measurements are performed in a darkened environment to prevent ambient light from accumulating in the long second exposure time. However, measurements of self-luminous processes (e.g. plasma, combustion ...) as well as experiments in ambient light are difficult to perform and require special equipment (external shutters, highspeed image sensors, multi-sensor systems ...). Unfortunately, all these methods incorporate different drawbacks such as reduced resolution, degraded image quality, decreased light sensitivity or increased susceptibility to decalibration. In the solution presented here, off-the-shelf CCD sensors are used with a special timing to combine neighbouring pixels in a binning-like way. As a result, two frames of short exposure time can be captured in fast succession. They are stored in the on-chip vertical register in a line-interleaved pattern, read out in the common way and separated again by software. The two resultant frames are completely congruent; they expose no insensitive lines or line shifts and thus enable sub-pixel accurate measurements. A third frame can be captured at the full resolution analogue to the double shutter technique. Image based measurement techniques such as PIV can benefit from this mode when applied in bright environments. The third frame is useful e.g. for acceleration measurements or for particle tracking applications.

  17. Programmable Aperture with MEMS Microshutter Arrays

    NASA Technical Reports Server (NTRS)

    Moseley, Samuel; Li, Mary; Kutyrev, Alexander; Kletetschka, Gunther; Fettig, Rainer

    2011-01-01

    A microshutter array (MSA) has been developed for use as an aperture array for multi-object selections in James Webb Space Telescope (JWST) technology. Light shields, molybdenum nitride (MoN) coating on shutters, and aluminum/aluminum oxide coatings on interior walls are put on each shutter for light leak prevention, and to enhance optical contrast. Individual shutters are patterned with a torsion flexure that permits shutters to open 90 deg. with a minimized mechanical stress concentration. The shutters are actuated magnetically, latched, and addressed electrostatically. Also, micromechanical features are tailored onto individual shutters to prevent stiction. An individual shutter consists of a torsion hinge, a shutter blade, a front electrode that is coated on the shutter blade, a backside electrode that is coated on the interior walls, and a magnetic cobalt-iron coating. The magnetic coating is patterned into stripes on microshutters so that shutters can respond to an external magnetic field for the magnetic actuation. A set of column electrodes is placed on top of shutters, and a set of row electrodes on sidewalls is underneath the shutters so that they can be electrostatically latched open. A linear permanent magnet is aligned with the shutter rows and is positioned above a flipped upside-down array, and sweeps across the array in a direction parallel to shutter columns. As the magnet sweeps across the array, sequential rows of shutters are rotated from their natural horizontal orientation to a vertical open position, where they approach vertical electrodes on the sidewalls. When the electrodes are biased with a sufficient electrostatic force to overcome the mechanical restoring force of torsion bars, shutters remain latched to vertical electrodes in their open state. When the bias is removed, or is insufficient, the shutters return to their horizontal, closed positions. To release a shutter, both the electrode on the shutter and the one on the back wall where the shutter sits are grounded. The shutters with one or both ungrounded electrodes are held open. Sub-micron bumps underneath light shields and silicon ribs on back walls are the two features to prevent stiction. These features ensure that the microshutter array functions properly in mechanical motions. The MSA technology can be used primarily in multi-object imaging and spectroscopy, photomask generation, light switches, and in the stepper equipment used to make integrated circuits and MEMS (microelectromechanical systems) devices.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cammarata, Marco; Eybert, Laurent; Ewald, Friederike

    A chopper system for time resolved pump-probe experiments with x-ray beams from a synchrotron is described. The system has three parts: a water-cooled heatload chopper, a high-speed chopper, and a millisecond shutter. The chopper system, which is installed in beamline ID09B at the European Synchrotron Radiation Facility, provides short x-ray pulses for pump-probe experiments with ultrafast lasers. The chopper system can produce x-ray pulses as short as 200 ns in a continuous beam and repeat at frequencies from 0 to 3 kHz. For bunch filling patterns of the synchrotron with pulse separations greater than 100 ns, the high-speed chopper canmore » isolate single 100 ps x-ray pulses that are used for the highest time resolution. A new rotor in the high-speed chopper is presented with a single pulse (100 ps) and long pulse (10 {mu}s) option. In white beam experiments, the heatload of the (noncooled) high-speed chopper is lowered by a heatload chopper, which absorbs 95% of the incoming power without affecting the pulses selected by the high speed chopper.« less

  19. Fast pulsed operation of a small non-radioactive electron source with continuous emission current control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cochems, P.; Kirk, A. T.; Bunert, E.

    Non-radioactive electron sources are of great interest in any application requiring the emission of electrons at atmospheric pressure, as they offer better control over emission parameters than radioactive electron sources and are not subject to legal restrictions. Recently, we published a simple electron source consisting only of a vacuum housing, a filament, and a single control grid. In this paper, we present improved control electronics that utilize this control grid in order to focus and defocus the electron beam, thus pulsing the electron emission at atmospheric pressure. This allows short emission pulses and excellent stability of the emitted electron currentmore » due to continuous control, both during pulsed and continuous operations. As an application example, this electron source is coupled to an ion mobility spectrometer. Here, the pulsed electron source allows experiments on gas phase ion chemistry (e.g., ion generation and recombination kinetics) and can even remove the need for a traditional ion shutter.« less

  20. Ion detection device and method with compressing ion-beam shutter

    DOEpatents

    Sperline, Roger P [Tucson, AZ

    2009-05-26

    An ion detection device, method and computer readable medium storing instructions for applying voltages to shutter elements of the detection device to compress ions in a volume defined by the shutter elements and to output the compressed ions to a collector. The ion detection device has a chamber having an inlet and receives ions through the inlet, a shutter provided in the chamber opposite the inlet and configured to allow or prevent the ions to pass the shutter, the shutter having first and second shutter elements, a collector provided in the chamber opposite the shutter and configured to collect ions passed through the shutter, and a processing unit electrically connected to the first and second shutter elements. The processing unit applies, during a first predetermined time interval, a first voltage to the first shutter element and a second voltage to the second shutter element, the second voltage being lower than the first voltage such that ions from the inlet enter a volume defined by the first and second shutter elements, and during a second predetermined time interval, a third voltage to the first shutter element, higher than the first voltage, and a fourth voltage to the second shutter element, the third voltage being higher than the fourth voltage such that ions that entered the volume are compressed as the ions exit the volume and new ions coming from the inlet are prevented from entering the volume. The processing unit is electrically connected to the collector and configured to detect the compressed ions based at least on a current received from the collector and produced by the ions collected by the collector.

  1. Thermal Powered Reciprocating-Force Motor

    NASA Technical Reports Server (NTRS)

    Tatum, III, Paul F. (Inventor); McDow Elliott, Amelia (Inventor)

    2015-01-01

    A thermal-powered reciprocating-force motor includes a shutter switchable between a first position that passes solar energy and a second position that blocks solar energy. A shape memory alloy (SMA) actuator is coupled to the shutter to control switching thereof between the shutter's first and second position. The actuator is positioned with respect to the shutter such that (1) solar energy impinges on the SMA when the shutter is in its first position so that the SMA experiences contraction in length until the shutter is switched to its second position, and (2) solar energy is impeded from impingement on the SMA when the shutter is in its second position so that the SMA experiences extension in length. Elastic members coupled to the actuator apply a force to the SMA that aids in its extension in length until the shutter is switched to its first position.

  2. Walory kulturowe Krainy Otwartych Okiennic

    NASA Astrophysics Data System (ADS)

    Matus, Irena

    2009-01-01

    The Open Shutters Land is an ethnographic-tourist project realizing in the territory of three villages in the north-east part of Poland. The shape of two of those villages (Soce and Trześcianka) as royal villages was created during włóka measurement in the 16th century. However Puchły was a private village. The aim of this project is to save wooden, unique, richly ornamented folk building industry. That enterprise came into being in the interwar period and was continued in the post-war period. Characteristic style of houses' decoration: geometric decorated shutters, subtle fretted label moulds, under-windows, boards corners sheltered, wind-protector are typical of that Land. Decorative shuttered timbered gables were graced. Street village ribbon development was built mainly gables to the street, whereas other inventory buildings were done in that same line. Two parish Orthodox churches, wooden, decorated in chisel style in Trześcianka and Puchły villages, a cemetery chapel in Trześcianka, two shrines nearby Soce and Trześcianka, interesting plague and intent crosses as well as original pillar shrines are worth seeing. Moreover, the Narew river, its inflow Rudnia and forests surrounding the villages exalt attraction of that terrain.

  3. Nano- and picosecond 3 μm Er: YSGG lasers using InAs as passive Q-switchers and mode-lockers

    NASA Astrophysics Data System (ADS)

    Vodopyanov, K. L.; Lukashev, A. V.; Phillips, C. C.

    1993-01-01

    Recent results are reported using ultra-thin molecular beam epitaxy (MBE)-grown InAs epilayers on GaAs substrates as passive shutters for 3 μm Er: YSGG lasers ( λ = 2.8 μm). The laser photon energy is 27% higher than the InAs bandgap at 300 K and bleaching occurs due to a band filling effect with a fast recovery time of < 100 ps. Depending on the resonator geometry two modes of operation can be achieved: Q-switched with pulse duration of 35 ns and 5-6 mJ energy (TEM 00 mode) and a Q-switched/mode-locked regime with an output in the form of a train of 30 pulses separated by a 4.3 ns interval, 0.25 mJ energy per spike and 30-50 ps pulse duration in a TEM 00-mode. The latter are the shortest pulses obtained with this lasing medium to date.

  4. A laser based frequency modulated NL-OSL phenomenon

    NASA Astrophysics Data System (ADS)

    Mishra, D. R.; Bishnoi, A. S.; Soni, Anuj; Rawat, N. S.; Bhatt, B. C.; Kulkarni, M. S.; Babu, D. A. R.

    2015-01-01

    The detailed theoretical and experimental approach to novel technique of pulse frequency modulated stimulation (PFMS) method has been described for NL-OSL phenomenon. This method involved pulsed frequency modulation with respect to time for fixed pulse width of 532 nm continuous wave (CW)-laser light. The linearly modulated (LM)-, non-linearly (NL)-stimulation profiles have been generated using fast electromagnetic optical shutter. The PFMS parameters have been determined for present experimental setup. The PFMS based LM-, NL-OSL studies have been carried out on dosimetry grade single crystal α-Al2O3:C. The photo ionization cross section of α-Al2O3:C has been found to be ∼9.97 × 10-19 cm2 for 532 nm laser light using PFMS LM-OSL studies under assumption of first order of kinetic. This method of PFMS is found to be a potential alternative to generate different stimulation profiles using CW-light sources.

  5. A pulse-forming network for particle path visualization. [at Ames Aeromechanics Water Tunnel Facility

    NASA Technical Reports Server (NTRS)

    Mcalister, K. W.

    1981-01-01

    A procedure is described for visualizing nonsteady fluid flow patterns over a wide velocity range using discrete nonluminous particles. The paramount element responsible for this capability is a pulse-forming network with variable inductance that is used to modulate the discharge of a fixed amount of electrical energy through a xenon flashtube. The selectable duration of the resultant light emission functions as a variable shutter so that particle path images of constant length can be recorded. The particles employed as flow markers are hydrogen bubbles that are generated by electrolysis in a water tunnel. Data are presented which document the characteristics of the electrical circuit and establish the relation of particle velocity to both section inductance and film exposure.

  6. Detonator-activated ball shutter

    DOEpatents

    McWilliams, Roy A.; von Holle, William G.

    1983-01-01

    A detonator-activated ball shutter for closing an aperture in about 300.mu. seconds. The ball shutter containing an aperture through which light, etc., passes, is closed by firing a detonator which propels a projectile for rotating the ball shutter, thereby blocking passage through the aperture.

  7. Detonator-activated ball shutter

    DOEpatents

    McWilliams, R.A.; Holle, W.G. von.

    1983-08-16

    A detonator-activated ball shutter for closing an aperture in about 300[mu] seconds. The ball shutter containing an aperture through which light, etc., passes, is closed by firing a detonator which propels a projectile for rotating the ball shutter, thereby blocking passage through the aperture. 3 figs.

  8. EEG-based usability assessment of 3D shutter glasses

    NASA Astrophysics Data System (ADS)

    Wenzel, Markus A.; Schultze-Kraft, Rafael; Meinecke, Frank C.; Cardinaux, Fabien; Kemp, Thomas; Müller, Klaus-Robert; Curio, Gabriel; Blankertz, Benjamin

    2016-02-01

    Objective. Neurotechnology can contribute to the usability assessment of products by providing objective measures of neural workload and can uncover usability impediments that are not consciously perceived by test persons. In this study, the neural processing effort imposed on the viewer of 3D television by shutter glasses was quantified as a function of shutter frequency. In particular, we sought to determine the critical shutter frequency at which the ‘neural flicker’ vanishes, such that visual fatigue due to this additional neural effort can be prevented by increasing the frequency of the system. Approach. Twenty-three participants viewed an image through 3D shutter glasses, while multichannel electroencephalogram (EEG) was recorded. In total ten shutter frequencies were employed, selected individually for each participant to cover the range below, at and above the threshold of flicker perception. The source of the neural flicker correlate was extracted using independent component analysis and the flicker impact on the visual cortex was quantified by decoding the state of the shutter from the EEG. Main Result. Effects of the shutter glasses were traced in the EEG up to around 67 Hz—about 20 Hz over the flicker perception threshold—and vanished at the subsequent frequency level of 77 Hz. Significance. The impact of the shutter glasses on the visual cortex can be detected by neurotechnology even when a flicker is not reported by the participants. Potential impact. Increasing the shutter frequency from the usual 50 Hz or 60 Hz to 77 Hz reduces the risk of visual fatigue and thus improves shutter-glass-based 3D usability.

  9. EEG-based usability assessment of 3D shutter glasses.

    PubMed

    Wenzel, Markus A; Schultze-Kraft, Rafael; Meinecke, Frank C; Fabien Cardinaux; Kemp, Thomas; Klaus-Robert Müller; Gabriel Curio; Benjamin Blankertz

    2016-02-01

    Neurotechnology can contribute to the usability assessment of products by providing objective measures of neural workload and can uncover usability impediments that are not consciously perceived by test persons. In this study, the neural processing effort imposed on the viewer of 3D television by shutter glasses was quantified as a function of shutter frequency. In particular, we sought to determine the critical shutter frequency at which the 'neural flicker' vanishes, such that visual fatigue due to this additional neural effort can be prevented by increasing the frequency of the system. Twenty-three participants viewed an image through 3D shutter glasses, while multichannel electroencephalogram (EEG) was recorded. In total ten shutter frequencies were employed, selected individually for each participant to cover the range below, at and above the threshold of flicker perception. The source of the neural flicker correlate was extracted using independent component analysis and the flicker impact on the visual cortex was quantified by decoding the state of the shutter from the EEG. Effects of the shutter glasses were traced in the EEG up to around 67 Hz-about 20 Hz over the flicker perception threshold-and vanished at the subsequent frequency level of 77 Hz. The impact of the shutter glasses on the visual cortex can be detected by neurotechnology even when a flicker is not reported by the participants. Potential impact. Increasing the shutter frequency from the usual 50 Hz or 60 Hz to 77 Hz reduces the risk of visual fatigue and thus improves shutter-glass-based 3D usability.

  10. X-ray source safety shutter

    DOEpatents

    Robinet, McLouis

    1977-05-31

    An apparatus is provided for controlling the activation of a high energy radiation source having a shutter. The apparatus includes magnets and magnetically responsive switches appropriately placed and interconnected so that only with the shutter and other parts of the source in proper position can safe emission of radiation out an open shutter occur.

  11. In-vacuum exposure shutter

    DOEpatents

    Johnson, Terry A.; Replogle, William C.; Bernardez, Luis J.

    2004-06-01

    An in-vacuum radiation exposure shutter device can be employed to regulate a large footprint light beam. The shutter device includes (a) a source of radiation that generates an energy beam; (2) a shutter that includes (i) a frame defining an aperture toward which the energy beam is directed and (ii) a plurality of blades that are secured to the frame; and (3) device that rotates the shutter to cause the plurality of blades to intercept or allow the energy beam to travel through the aperture. Each blade can have a substantially planar surface and the plurality of blades are secured to the frame such that the planar surfaces of the plurality of blades are substantially parallel to each other. The shutter device is particularly suited for operation in a vacuum environment and can achieve shuttering speeds from about 0.1 second to 0.001 second or faster.

  12. FPGA Control System for the Automated Test of MicroShutters

    NASA Technical Reports Server (NTRS)

    Lyness, Eric; Rapchun, David A.; Moseley, S. Harvey

    2008-01-01

    The James Webb Space Telescope, scheduled to replace the Hubble in 2013, must simultaneously observe hundreds of faint galaxies. This requirement has led to the development of a programmable transmission mask which can be adapted to admit light from an arbitrary pattern of galaxies into its spectrograph. This programmable mask will contain a large array of micro-electromechanical (MEMs) devices called MicroShutters. These microscopic shutters physically open and close like the shutter on a camera, except each shutter is microscopic in size and an array 365 by 171 is used to select the objects under spectroscopic observation at a given time, and to block the unwanted background light from other areas. NASA developed and is currently refining the exceptionally difficult process of manufacturing these shutters. This paper describes how the authors used LabVIEW FPGA and a reconfigurable I/O board to control the shutters in a test chamber and how the flexibility of the system allows us to continue to modify the control algorithms as NASA optimizes the performance of the MicroShutter arrays.

  13. Thematic mapper flight model preshipment review data package. Volume 4: Appendix. Part E: Electronics module data

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Tests to verify the as-designed performance of all circuits within the thematic mapper electronics module unit are described. Specifically, the tests involved the evaluation of the scan line corrector driver, shutter drivers function, cal lamp controller function, post amplifier function, command decoder verification unit, and the temperature and actuator controllers function.

  14. Photogrammetric Accuracy and Modeling of Rolling Shutter Cameras

    NASA Astrophysics Data System (ADS)

    Vautherin, Jonas; Rutishauser, Simon; Schneider-Zapp, Klaus; Choi, Hon Fai; Chovancova, Venera; Glass, Alexis; Strecha, Christoph

    2016-06-01

    Unmanned aerial vehicles (UAVs) are becoming increasingly popular in professional mapping for stockpile analysis, construction site monitoring, and many other applications. Due to their robustness and competitive pricing, consumer UAVs are used more and more for these applications, but they are usually equipped with rolling shutter cameras. This is a significant obstacle when it comes to extracting high accuracy measurements using available photogrammetry software packages. In this paper, we evaluate the impact of the rolling shutter cameras of typical consumer UAVs on the accuracy of a 3D reconstruction. Hereto, we use a beta-version of the Pix4Dmapper 2.1 software to compare traditional (non rolling shutter) camera models against a newly implemented rolling shutter model with respect to both the accuracy of geo-referenced validation points and to the quality of the motion estimation. Multiple datasets have been acquired using popular quadrocopters (DJI Phantom 2 Vision+, DJI Inspire 1 and 3DR Solo) following a grid flight plan. For comparison, we acquired a dataset using a professional mapping drone (senseFly eBee) equipped with a global shutter camera. The bundle block adjustment of each dataset shows a significant accuracy improvement on validation ground control points when applying the new rolling shutter camera model for flights at higher speed (8m=s). Competitive accuracies can be obtained by using the rolling shutter model, although global shutter cameras are still superior. Furthermore, we are able to show that the speed of the drone (and its direction) can be solely estimated from the rolling shutter effect of the camera.

  15. Synchronized Electronic Shutter System (SESS) for Thermal Nondestructive Evaluation

    NASA Technical Reports Server (NTRS)

    Zalameda, Joseph N.

    2001-01-01

    The purpose of this paper is to describe a new method for thermal nondestructive evaluation. This method uses a synchronized electronic shutter system (SESS) to remove the heat lamp's influence on the thermal data during and after flash heating. There are two main concerns when using flash heating. The first concern is during the flash when the photons are reflected back into the camera. This tends to saturate the detectors and potentially introduces unknown and uncorrectable errors when curve fitting the data to a model. To address this, an electronically controlled shutter was placed over the infrared camera lens. Before firing the flash lamps, the shutter is opened to acquire the necessary background data for offset calibration. During flash heating, the shutter is closed to prevent the photons from the high intensity flash from saturating the camera's detectors. The second concern is after the flash heating where the lamps radiate heat after firing. This residual cooling introduces an unwanted transient thermal response into the data. To remove this residual effect, a shutter was placed over the flash lamps to block the infrared heat radiating from the flash head after heating. This helped to remove the transient contribution of the flash. The flash lamp shutters were synchronized electronically with the camera shutter. Results are given comparing the use of the thermal inspection with and without the shutter system.

  16. Double-layered liquid crystal light shutter for control of absorption and scattering of the light incident to a transparent display device

    NASA Astrophysics Data System (ADS)

    Huh, Jae-Won; Yu, Byeong-Hun; Shin, Dong-Myung; Yoon, Tae-Hoon

    2015-03-01

    Recently, a transparent display has got much attention as one of the next generation display devices. Especially, active studies on a transparent display using organic light-emitting diodes (OLEDs) are in progress. However, since it is not possible to obtain black color using a transparent OLED, it suffers from poor visibility. This inevitable problem can be solved by using a light shutter. Light shutter technology can be divided into two types; light absorption and scattering. However, a light shutter based on light absorption cannot block the background image perfectly and a light shutter based on light scattering cannot provide black color. In this work we demonstrate a light shutter using two liquid crystal (LC) layers, a light absorption layer and a light scattering layer. To realize a light absorption layer and a light scattering layer, we use the planar state of a dye-doped chiral nematic LC (CNLC) cell and the focal-conic state of a long-pitch CNLC cell, respectively. The proposed light shutter device can block the background image perfectly and show black color. We expect that the proposed light shutter can increase the visibility of a transparent display.

  17. The IRAC Shutter Mechanism: Residual Magnetism and the Rotary Solenoid

    NASA Technical Reports Server (NTRS)

    Schwinger, Scott; Hakun, Claef; Brown, Gary; Blumenstock, Ken

    2002-01-01

    The Infrared Array Camera (IRAC) Shutter mechanism was originally presented in the paper, 'A Low Power Cryogenic Shutter Mechanism for Use on Infrared Imagers' at the 34th Aerospace Mechanisms Symposium, May 2000. At that time, the shutter was believed to be performing flawlessly and there was every indication it would continue to do so. In early spring of 2001, the calibration shutter, a rotary solenoid designed to be fail-safe open, remained in a closed state with no power to the electromagnetic coils. The ensuing investigation, subsequent testing, proposed remedy, and lessons learned are the focus of this paper.

  18. Nd:YAP laser pulse compression by three-stage transient stimulated Brillouin and Raman scattering

    NASA Astrophysics Data System (ADS)

    Kubeček, V.; Hamal, K.; Procházka, I.; Buzelis, R.; Girdauskas, V.; Dementiev, A.

    1991-08-01

    There is a continuous effort to generate stable, powerful picosecond laser pulses for application in spectroscopy, nonlinear optics and parametric light generation, as well. One of the possible methods is the compression of longer nanosecond laser pulses by stimulated Brillouin and stimulated Raman scattering. The advantages of such a technique, in comparison to the used mode locked picosecond lasers, are as follows: the absence of the active and/or passive mode lockers used to generate a train of picosecond pulses, and the absence of a fast electrooptical shutter used to select a single pulse from a train of pulses. The application of stimulated Brillouin and stimulated Raman scattering permits to generate picosecond pulses in the wavelength regions not covered by mode locked lasers. Of special interest is the wavelength region of 0·8 μm, which may be amplified by the attractive Titanium Sapphire lasers. In this paper we are summarizing our results in theoretical modelling and in real generation of picosecond pulses by means of cascaded stimulated Brillouin and Raman scattering. The models of scattering processes have been investigated. The stable generation of 5, 7, 3 picosecond pulses have been optimized for the wavelengths of 0·8, 0·64 and 0·54 μm, respectively. In all these cases, the pulses exhibited the far field pattern close to Gaussian, with the pulse energy ranging from 0·2 to 1 mJ.

  19. Advanced Shutter Control for a Molecular Beam Epitaxy Reactor

    DTIC Science & Technology

    An open-source hardware and software-based shutter controller solution was developed that communicates over Ethernet with our original equipment...manufacturer (OEM) molecular beam epitaxy (MBE) reactor control software. An Arduino Mega microcontroller is the used for the brain of the shutter... controller , while a custom-designed circuit board distributes 24-V power to each of the 16 shutter solenoids available on the MBE. Using Ethernet

  20. Application of PLZT electro-optical shutter to diaphragm of visible and mid-infrared cameras

    NASA Astrophysics Data System (ADS)

    Fukuyama, Yoshiyuki; Nishioka, Shunji; Chonan, Takao; Sugii, Masakatsu; Shirahata, Hiromichi

    1997-04-01

    Pb0.9La0.09(Zr0.65,Ti0.35)0.9775O3 9/65/35) commonly used as an electro-optical shutter exhibits large phase retardation with low applied voltage. This shutter features as follows; (1) high shutter speed, (2) wide optical transmittance, and (3) high optical density in 'OFF'-state. If the shutter is applied to a diaphragm of video-camera, it could protect its sensor from intense lights. We have tested the basic characteristics of the PLZT electro-optical shutter and resolved power of imaging. The ratio of optical transmittance at 'ON' and 'OFF'-states was 1.1 X 103. The response time of the PLZT shutter from 'ON'-state to 'OFF'-state was 10 micro second. MTF reduction when putting the PLZT shutter in from of the visible video- camera lens has been observed only with 12 percent at a spatial frequency of 38 cycles/mm which are sensor resolution of the video-camera. Moreover, we took the visible image of the Si-CCD video-camera. The He-Ne laser ghost image was observed at 'ON'-state. On the contrary, the ghost image was totally shut out at 'OFF'-state. From these teste, it has been found that the PLZT shutter is useful for the diaphragm of the visible video-camera. The measured optical transmittance of PLZT wafer with no antireflection coating was 78 percent over the range from 2 to 6 microns.

  1. Hollow waveguide for giant Er:YAG laser pulses transfer

    NASA Astrophysics Data System (ADS)

    Nemec, Michal; Jelinkova, Helena; Koranda, Petr; Cech, Miroslav; Sulc, Jan; Miyagi, Mitsunobu; Shi, Yi-Wei; Matsuura, Yuji

    2004-06-01

    Short Er:YAG laser pulses were delivered by a cyclic olefin polymer coated silver hollow glass (COP/Ag) waveguide specially designed for a high power radiation. Er:YAG laser was Q-switched by an electro-optic shutter - LiNbO3 Pockels cell with Brewster angle cut input/output faces. The maximum energy output obtained from this system was 29 mJ with the length of pulse 69 ns corresponding to 420 kW output peak power. The system was working with the repetition rate of 1.5 Hz. A delivery system composed of a lens (f = 40 mm), protector and waveguide with the 700/850 μm diameter and 50 cm or 1 m length. The measured maximum delivered intensity was 86 MW/cm2 what corresponds to the transmission of 78.6 % for whole delivery system. Using of a sealed cap, this delivery system gives a possibility of the contact surgical treatment in many medicine branches, for example ophthalmology, urology or dentistry.

  2. Advanced electro-mechanical micro-shutters for thermal infrared night vision imaging and targeting systems

    NASA Astrophysics Data System (ADS)

    Durfee, David; Johnson, Walter; McLeod, Scott

    2007-04-01

    Un-cooled microbolometer sensors used in modern infrared night vision systems such as driver vehicle enhancement (DVE) or thermal weapons sights (TWS) require a mechanical shutter. Although much consideration is given to the performance requirements of the sensor, supporting electronic components and imaging optics, the shutter technology required to survive in combat is typically the last consideration in the system design. Electro-mechanical shutters used in military IR applications must be reliable in temperature extremes from a low temperature of -40°C to a high temperature of +70°C. They must be extremely light weight while having the ability to withstand the high vibration and shock forces associated with systems mounted in military combat vehicles, weapon telescopic sights, or downed unmanned aerial vehicles (UAV). Electro-mechanical shutters must have minimal power consumption and contain circuitry integrated into the shutter to manage battery power while simultaneously adapting to changes in electrical component operating parameters caused by extreme temperature variations. The technology required to produce a miniature electro-mechanical shutter capable of fitting into a rifle scope with these capabilities requires innovations in mechanical design, material science, and electronics. This paper describes a new, miniature electro-mechanical shutter technology with integrated power management electronics designed for extreme service infra-red night vision systems.

  3. FPGA Control System for the Automated Test of Microshutters

    NASA Technical Reports Server (NTRS)

    Lyness, Eric; Rapchun, David A.; Moseley, S. Harvey

    2008-01-01

    The James Webb Space Telescope, scheduled to replace the Hubble in 2013, must simultaneously observe hundreds of faint galaxies. This requirement has led to the development of a programmable transmission mask which can be adapted to admit light with arbitrary pattern of galaxies into its spectrograph. This programmable mask will contain a large array of micro-electromechanical (MEMs) devices called MicroShutters. These microscopic shutters physically open and close like the shutter on a camera, except each shutter is microscopic in size and an array 365 by 171 is used to select the objects under spectroscopic observation at a given time, and to block the unwanted background light from other areas. NASA developed and is currently refining the exceptionally difficult process of manufacturing these shutters. This paper describes how the authors used LabVIEW FPGA and a reconfigurable I/O board to control the shutters in a test chamber and how the flexibility of the system allows us to continue to modify the control algorithms as NASA optimizes the performance of the MicroShutter arrays.

  4. X-Ray Pulse Selector With 2 ns Lock-in Phase Setting And Stability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindenau, B.; Raebiger, J.; Polachowski, S.

    2004-05-12

    Selector devices, which are based on magnetically suspended, high speed triangular shutter rotors, have been designed and built in cooperation with ESRF, APS, and recently Spring-8 for time resolved studies with isolated x-ray pulses at white beam lines. The x-ray pulse selection is accomplished by means of a beam channel along one of the edges of the triangular rotor, which opens once per revolution. Entrance and exit apertures of the channel can be designed wedge shaped for variable tuning of the channel height between 0.1 mm to 0.9 mm. At the 1 kHz maximum operation frequency of a 220 mmmore » diameter disk with 190 mm channel length, the practicable open times of the channel are demonstrated to range down to 200 ns. The selector drive electronics is directly coupled to the storage ring RF clock for rotational phase control. It allows for continuous selector operation in phase locked mode to the temporal pulse structure of the synchrotron at 2 ns RMS stability. The phase angle between the pulse transmission period and the synchrotron bunch sequence can be adjusted with similar precision for X-ray pulse selection according to the experimental needs. ID09, Michael Wulff ; BioCARS 14-BM, Reinhard Pahl; BL40-XU, Shin-ichi Adachi.« less

  5. Some Aspects on the Mechanical Analysis of Micro-Shutters

    NASA Technical Reports Server (NTRS)

    Fettig, Rainer K.; Kuhn, Jonathan L.; Moseley, S. Harvey; Kutyrev, Alexander S.; Orloff, Jon; Lu, Shude

    1999-01-01

    An array of individually addressable micro-shutters is being designed for spectroscopic applications. Details of the design are presented in a companion paper. The mechanical design of a single shutter element has been completed. This design consists of a shutter blade suspended on a torsion beam manufactured out of single crystal silicon membranes. During operation the shutter blade will be rotated by 90 degrees out of the array plane. Thus, the stability and durability of the beams are crucial for the reliability of the devices. Structures were fabricated using focused ion beam milling in a FEI 620 dual beam machine, and subsequent testing was completed using the same platform. This allowed for short turn around times. We performed torsion and bending experiments to determine key characteristics of the membrane material. Results of measurements on prototype shutters were compared with the predictions of the numerical models. The data from these focused studies were used in conjunction with experiments and numerical models of shutter prototypes to optimize the design. In this work, we present the results of the material studies, and assess the mechanical performance of the resulting design.

  6. Focal Plane Array Shutter Mechanism of the JWST NIRSpec Detector System

    NASA Technical Reports Server (NTRS)

    Hale, Kathleen; Sharma, Rajeev

    2006-01-01

    This viewgraph presentation reviews the requirements, chamber location, shutter system design, stepper motor specifications, dry lubrication, control system, the environmental cryogenic function testing and the test results of the Focal Plane Array Shutter mechanism for the James Webb Space Telescope Near Infrared Spectrum Detector system. Included are design views of the location for the Shutter Mechanism, lubricant (lubricated with Molybdenum Di Sulfide) thickness, and information gained from the cryogenic testing.

  7. Testing Microshutter Arrays Using Commercial FPGA Hardware

    NASA Technical Reports Server (NTRS)

    Rapchun, David

    2008-01-01

    NASA is developing micro-shutter arrays for the Near Infrared Spectrometer (NIRSpec) instrument on the James Webb Space Telescope (JWST). These micro-shutter arrays allow NIRspec to do Multi Object Spectroscopy, a key part of the mission. Each array consists of 62414 individual 100 x 200 micron shutters. These shutters are magnetically opened and held electrostatically. Individual shutters are then programmatically closed using a simple row/column addressing technique. A common approach to provide these data/clock patterns is to use a Field Programmable Gate Array (FPGA). Such devices require complex VHSIC Hardware Description Language (VHDL) programming and custom electronic hardware. Due to JWST's rapid schedule on the development of the micro-shutters, rapid changes were required to the FPGA code to facilitate new approaches being discovered to optimize the array performance. Such rapid changes simply could not be made using conventional VHDL programming. Subsequently, National Instruments introduced an FPGA product that could be programmed through a Labview interface. Because Labview programming is considerably easier than VHDL programming, this method was adopted and brought success. The software/hardware allowed the rapid change the FPGA code and timely results of new micro-shutter array performance data. As a result, numerous labor hours and money to the project were conserved.

  8. Elastic Distribution of Microshutters, Measurements Obtainable on James Web Space Telescope

    NASA Technical Reports Server (NTRS)

    Kletetschka, Gunther; King, Todd; Mikula, Vilem

    2008-01-01

    Spectrographic astronomy measurements in the near-infrared region will be done by functional two-dimensional microshutter arrays that are being fabricated at the NASA Goddard Space Flight Center for the James Webb Space Telescope (JWST). These micro-shutter arrays will represent the first mission-critical MEMS devices to be flown in space. JWST will use microshutter arrays to select focal plane object. 2-D programmable aperture masks of more than 200,000 elements select such space object. The use of silicon wafer material promises high efficiency and high contrast. Microshutter operation temperature is around 35K. Microshutter arrays are fabricated as close-packed silicon nitride membranes with a unit cell size of 105 x 204 micrometers. A layer of magnetic material is deposited onto each shutter. Individual shutters are equipped with a torsion flexure. Reactive ion etching (RIE) releases the shutters so they can open up to 90 degrees using the torsion flexure. Shutter rotation is initiated into a silicon support structure via an external magnetic field. Two electrically independent aluminum electrodes are deposited, one onto each shutter and another onto the support structure side-wall, permitting electrostatic latching and 2-D addressing to hold specific shutters open via external electronics.

  9. Automatic lightning detection and photographic system

    NASA Technical Reports Server (NTRS)

    Wojtasinski, R. J.; Holley, L. D.; Gray, J. L.; Hoover, R. B. (Inventor)

    1972-01-01

    A system is presented for monitoring and recording lightning strokes within a predetermined area with a camera having an electrically operated shutter with means for advancing the film in the camera after activating the shutter. The system includes an antenna for sensing lightning strikes which, in turn, generates a signal that is fed to an electronic circuit which generates signals for operating the shutter of the camera. Circuitry is provided for preventing activation of the shutter as the film in the camera is being advanced.

  10. Advances in shutter drive technology to enhance man-portable infrared cameras

    NASA Astrophysics Data System (ADS)

    Durfee, David

    2012-06-01

    With an emphasis on highest reliability, infrared (IR) imagers have traditionally used simplest-possible shutters and field-proven technology. Most commonly, single-step rotary or linear magnetic actuators have been used with good success. However, several newer shutter drive technologies offer benefits in size and power reduction, enabling man-portable imagers that are more compact, lighter, and more durable. This paper will discuss improvements in shutter and shutter drive technology, which enable smaller and more power-efficient imagers. Topics will transition from single-step magnetic actuators to multi-stepping magnetic drives, latching vs. balanced systems for blade position shock-resistance, motor and geared motor drives, and associated stepper driver electronics. It will highlight performance tradeoffs pertinent to man-portable military systems.

  11. Motion Sickness Treatment Apparatus and Method

    NASA Technical Reports Server (NTRS)

    Reschke, Millard F. (Inventor); Somers, Jeffrey T. (Inventor); Ford, George A. (Inventor)

    2005-01-01

    Methods and apparatus are disclosed for treating motion sickness. In a preferred embodiment a method of the invention comprises operating eyewear having shutter lenses to open said shutter lenses at a selected operating frequency ranging from within about 3 Hz to about 50 Hz. The shutter lenses are opened for a short duration at the selected operating frequency wherein the duration is selected to prevent retinal slip. The shutter lenses may be operated at a relatively slow frequency of about 4 Hz when the user is in passive activity such as riding in a boat or car or in limited motion situations in a spacecraft. The shutter lenses may be operated at faster frequencies related to motion of the user's head when the user is active.

  12. Demonstrations with a Liquid Crystal Shutter

    ERIC Educational Resources Information Center

    Kraftmakher, Yaakov

    2012-01-01

    The experiments presented show the response of a liquid crystal shutter to applied electric voltages and the delay of the operations. Both properties are important for liquid crystal displays of computers and television sets. Two characteristics of the shutter are determined: (i) the optical transmittance versus applied voltage of various…

  13. Use of color-coded sleeve shutters accelerates oscillograph channel selection

    NASA Technical Reports Server (NTRS)

    Bouchlas, T.; Bowden, F. W.

    1967-01-01

    Sleeve-type shutters mechanically adjust individual galvanometer light beams onto or away from selected channels on oscillograph papers. In complex test setups, the sleeve-type shutters are color coded to separately identify each oscillograph channel. This technique could be used on any equipment using tubular galvanometer light sources.

  14. Variable orifice using an iris shutter

    DOEpatents

    Beeman, Raymond; Brajkovich, Steven J.

    1978-01-01

    A variable orifice forming mechanism utilizing an iris shutter arrangement adapted to control gas flow, conductance in vacuum systems, as a heat shield for furnace windows, as a beam shutter in sputtering operations, and in any other application requiring periodic or continuously-variable control of material, gas, or fluid flow.

  15. MEMS Microshutter Arrays for James Webb Space Telescope

    NASA Technical Reports Server (NTRS)

    Li, Mary J.; Beamesderfer, Michael; Babu, Sachi; Bajikar, Sateesh; Ewin, Audrey; Franz, Dave; Hess, Larry; Hu, Ron; Jhabvala, Murzy; Kelly, Dan; hide

    2006-01-01

    MEMS microshutter arrays are being developed at NASA Goddard Space Flight Center for use as an aperture array for a Near-Infrared Spectrometer (NirSpec). The instruments will be carried on the James Webb Space Telescope (JWST), the next generation of space telescope after Hubble Space Telescope retires. The microshutter arrays are designed for the selective transmission of light with high efficiency and high contrast, Arrays are close-packed silicon nitride membranes with a pixel size of 100x200 microns. Individual shutters are patterned with a torsion flexure permitting shutters to open 90 degrees with a minimized mechanical stress concentration. Light shields are made on to each shutter for light leak prevention so to enhance optical contrast, Shutters are actuated magnetically, latched and addressed electrostatically. The shutter arrays are fabricated using MEMS technologies.

  16. Method and system for nanoscale plasma processing of objects

    DOEpatents

    Oehrlein, Gottlieb S [Clarksville, MD; Hua, Xuefeng [Hyattsville, MD; Stolz, Christian [Baden-Wuerttemberg, DE

    2008-12-30

    A plasma processing system includes a source of plasma, a substrate and a shutter positioned in close proximity to the substrate. The substrate/shutter relative disposition is changed for precise control of substrate/plasma interaction. This way, the substrate interacts only with a fully established, stable plasma for short times required for nanoscale processing of materials. The shutter includes an opening of a predetermined width, and preferably is patterned to form an array of slits with dimensions that are smaller than the Debye screening length. This enables control of the substrate/plasma interaction time while avoiding the ion bombardment of the substrate in an undesirable fashion. The relative disposition between the shutter and the substrate can be made either by moving the shutter or by moving the substrate.

  17. Reduction of background clutter in structured lighting systems

    DOEpatents

    Carlson, Jeffrey J.; Giles, Michael K.; Padilla, Denise D.; Davidson, Jr., Patrick A.; Novick, David K.; Wilson, Christopher W.

    2010-06-22

    Methods for segmenting the reflected light of an illumination source having a characteristic wavelength from background illumination (i.e. clutter) in structured lighting systems can comprise pulsing the light source used to illuminate a scene, pulsing the light source synchronously with the opening of a shutter in an imaging device, estimating the contribution of background clutter by interpolation of images of the scene collected at multiple spectral bands not including the characteristic wavelength and subtracting the estimated background contribution from an image of the scene comprising the wavelength of the light source and, placing a polarizing filter between the imaging device and the scene, where the illumination source can be polarized in the same orientation as the polarizing filter. Apparatus for segmenting the light of an illumination source from background illumination can comprise an illuminator, an image receiver for receiving images of multiple spectral bands, a processor for calculations and interpolations, and a polarizing filter.

  18. Rejection of fluorescence background in resonance and spontaneous Raman microspectroscopy.

    PubMed

    Smith, Zachary J; Knorr, Florian; Pagba, Cynthia V; Wachsmann-Hogiu, Sebastian

    2011-05-18

    Raman spectroscopy is often plagued by a strong fluorescent background, particularly for biological samples. If a sample is excited with a train of ultrafast pulses, a system that can temporally separate spectrally overlapping signals on a picosecond timescale can isolate promptly arriving Raman scattered light from late-arriving fluorescence light. Here we discuss the construction and operation of a complex nonlinear optical system that uses all-optical switching in the form of a low-power optical Kerr gate to isolate Raman and fluorescence signals. A single 808 nm laser with 2.4 W of average power and 80 MHz repetition rate is split, with approximately 200 mW of 808 nm light being converted to < 5 mW of 404 nm light sent to the sample to excite Raman scattering. The remaining unconverted 808 nm light is then sent to a nonlinear medium where it acts as the pump for the all-optical shutter. The shutter opens and closes in 800 fs with a peak efficiency of approximately 5%. Using this system we are able to successfully separate Raman and fluorescence signals at an 80 MHz repetition rate using pulse energies and average powers that remain biologically safe. Because the system has no spare capacity in terms of optical power, we detail several design and alignment considerations that aid in maximizing the throughput of the system. We also discuss our protocol for obtaining the spatial and temporal overlap of the signal and pump beams within the Kerr medium, as well as a detailed protocol for spectral acquisition. Finally, we report a few representative results of Raman spectra obtained in the presence of strong fluorescence using our time-gating system.

  19. Development of double-pulse lasers ablation system for generating gold ion source under applying an electric field

    NASA Astrophysics Data System (ADS)

    Khalil, A. A. I.

    2015-12-01

    Double-pulse lasers ablation (DPLA) technique was developed to generate gold (Au) ion source and produce high current under applying an electric potential in an argon ambient gas environment. Two Q-switched Nd:YAG lasers operating at 1064 and 266 nm wavelengths are combined in an unconventional orthogonal (crossed-beam) double-pulse configuration with 45° angle to focus on a gold target along with a spectrometer for spectral analysis of gold plasma. The properties of gold plasma produced under double-pulse lasers excitation were studied. The velocity distribution function (VDF) of the emitted plasma was studied using a dedicated Faraday-cup ion probe (FCIP) under argon gas discharge. The experimental parameters were optimized to attain the best signal to noise (S/N) ratio. The results depicted that the VDF and current signals depend on the discharge applied voltage, laser intensity, laser wavelength and ambient argon gas pressure. A seven-fold increases in the current signal by increasing the discharge applied voltage and ion velocity under applying double-pulse lasers field. The plasma parameters (electron temperature and density) were also studied and their dependence on the delay (times between the excitation laser pulse and the opening of camera shutter) was investigated as well. This study could provide significant reference data for the optimization and design of DPLA systems engaged in laser induced plasma deposition thin films and facing components diagnostics.

  20. Solar shutter arrangement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fulkerson, P.L.

    1988-02-02

    In a structure having a roof with a skylight including a glass panel which transmits solar energy, a shutter arrangement supported on the roof is described comprising an insulative flat one-piece solid shutter in the form of a panel selectively and linearly slidable on tracks which conceal the side edges thereof from a position blocking transmittal of solar energy through the glass panel of the skylight into an area within the structure to a position permitting transmittal of solar energy through the glass panel of the skylight into the area within the structure. The skylight presents a space between themore » glass panel and the selectively and linearly slidable insulative flat one-piece solid shutter, where the latter serves as the selective inner wall of the space contiguous with the area within the structure and the glass panel serves as the fixed outer wall of the space, where temperature responsive means is disposed within the space and in direct engagement with the inner surface of the glass panel, where the temperature responsive means is a black thermocouple operating a motor in a driving relationship with the insulative flat one-piece solid shutter. The insulative flat one-piece solid shutter is supported by a cable secured to a rotatable shaft controlled by the motor, where bi-directional movement of the rotatable shaft achieves raising and lowering of the insulative flat one-piece solid shutter to each of the solar energy blocking and transmittal positions, and where the insulative flat one-piece solid shutter includes a reflective surface facing the skylight and a decorative surface facing the area within the structure.« less

  1. Solar Skylight

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adamson, J. C.

    1984-01-31

    A reflective shutter rotates within a skylight housing in such a fashion as to control solar energy thereby providing a combination of heating, lighting, and ventilation. The skylight housing has three faces: a glazed southern face, a glazed northern face, and an open downwardly oriented face to the interior of the structure. Counter-weighted pivot arms support the shutter at either end causing the center of rotation to pass through the center of gravity. The shutter has three basic positions: In the first position, during the winter day, the shutter closes off the northern face, allowing solar energy to enter directlymore » into the supporting structure providing heat gain and daylighting. In the second position, during the winter night, the shutter closes off the open face to the interior, providing insulation between the structure and the skylight housing. In the third position, during the non-heating season, the shutter closes off the southern face blocking unwanted heat gain but allowing diffuse northern light to penetrate for daylighting. In this last position, a means is provided for ventilating by natural convection. The apparatus can be operated either manually or by motor.« less

  2. Solar skylight

    DOEpatents

    Adamson, James C.

    1984-01-01

    A reflective shutter rotates within a skylight housing in such a fashion as to control solar energy thereby providing a combination of heating, lighting, and ventilation. The skylight housing has three faces: a glazed southern face, a glazed northern face, and an open downwardly oriented face to the interior of the structure. Counter-weighted pivot arms support the shutter at either end causing the center of rotation to pass through the center of gravity. The shutter has three basic positions: In the first position, during the winter day, the shutter closes off the northern face, allowing solar energy to enter directly into the supporting structure providing heat gain and daylighting. In the second position, during the winter night, the shutter closes off the open face to the interior, providing insulation between the structure and the skylight housing. In the third position, during the non-heating season, the shutter closes off the southern face blocking unwanted heat gain but allowing diffuse northern light to penetrate for daylighting. In this last position, a means is provided for ventilating by natural convection. The apparatus can be operated either manually or by motor.

  3. Apparatus for insulating windows and the like

    DOEpatents

    Mitchell, R.A.

    1984-06-19

    Apparatus for insulating window openings through walls and the like includes a thermal shutter, a rail for mounting the shutter adjacent to the window opening and a coupling for connecting the shutter to the rail. The thermal shutter includes an insulated panel adhered to frame members which surround the periphery of the panel. The frame members include a hard portion for providing the frame and a soft portion for providing a seal with that portion of the wall adjacent to the periphery of the opening. The coupling means is preferably integral with the attachment rail. According to a preferred embodiment, the coupling means includes a continuous hinge of reduced thickness. The thermal shutter can be permanently attached, hinged, bi-folded, or sliding with respect to the window and wall. A distribution method is to market the apparatus in kit'' form. 11 figs.

  4. Apparatus for insulating windows and the like

    DOEpatents

    Mitchell, Robert A.

    1984-01-01

    Apparatus for insulating window openings through walls and the like includes a thermal shutter, a rail for mounting the shutter adjacent to the window opening and a coupling for connecting the shutter to the rail. The thermal shutter includes an insulated panel adhered to frame members which surround the periphery of the panel. The frame members include a hard portion for providing the frame and a soft portion for providing a seal with that portion of the wall adjacent to the periphery of the opening. The coupling means is preferably integral with the attachment rail. According to a preferred embodiment, the coupling means includes a continuous hinge of reduced thickness. The thermal shutter can be permanently attached, hinged, bi-folded, or sliding with respect to the window and wall. A distribution method is to market the apparatus in "kit" form.

  5. Configuring and Characterizing X-Rays for Laser-Driven Compression Experiments at the Dynamic Compression Sector

    NASA Astrophysics Data System (ADS)

    Li, Y.; Capatina, D.; D'Amico, K.; Eng, P.; Hawreliak, J.; Graber, T.; Rickerson, D.; Klug, J.; Rigg, P. A.; Gupta, Y. M.

    2017-06-01

    Coupling laser-driven compression experiments to the x-ray beam at the Dynamic Compression Sector (DCS) at the Advanced Photon Source (APS) of Argonne National Laboratory requires state-of-the-art x-ray focusing, pulse isolation, and diagnostics capabilities. The 100J UV pulsed laser system can be fired once every 20 minutes so precise alignment and focusing of the x-rays on each new sample must be fast and reproducible. Multiple Kirkpatrick-Baez (KB) mirrors are used to achieve a focal spot size as small as 50 μm at the target, while the strategic placement of scintillating screens, cameras, and detectors allows for fast diagnosis of the beam shape, intensity, and alignment of the sample to the x-ray beam. In addition, a series of x-ray choppers and shutters are used to ensure that the sample is exposed to only a single x-ray pulse ( 80ps) during the dynamic compression event and require highly precise synchronization. Details of the technical requirements, layout, and performance of these instruments will be presented. Work supported by DOE/NNSA.

  6. Smart window using a thermally and optically switchable liquid crystal cell

    NASA Astrophysics Data System (ADS)

    Oh, Seung-Won; Kim, Sang-Hyeok; Baek, Jong-Min; Yoon, Tae-Hoon

    2018-02-01

    Light shutter technologies that can control optical transparency have been studied extensively for developing curtain-free smart windows. We introduce thermally and optically switchable light shutters using LCs doped with push-pull azobenzene, which is known to speed up thermal relaxation. The liquid crystal light shutter can be switched between translucent and transparent states or transparent and opaque states by phase transition through changing temperature or photo-isomerization of doped azobenzene. The liquid crystal light shutter can be used for privacy windows with an initial translucent state or energy-saving windows with an initial transparent state.

  7. IMPROVEMENTS IN RADIATION SHUTTERS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1961-07-12

    An apparatus for the protection of eyesight from the radiated energy released from a thermonuclear explosion is described. The apparatus consists of a shutter which is opaque to the radiation, an electrically ignitible detonator for blowing the shutter across the path of the radiation, and a phototransistor for igniting the detonator when the radiated energy exceeds a level which is injurious to the eyesight. There may be a second detonator for blowing the shutter away after the explosion has subsided. The second detonator is manually operated. Diagrams show the apparatus attached to a soldier's helmet and a turret. (N.W.R.)

  8. N-acetylcysteine and acute retinal laser lesions in the colubrid snake eye

    NASA Astrophysics Data System (ADS)

    Elliott, William R., III; Rentmeister-Bryant, Heike K.; Barsalou, Norman; Beer, Jeremy; Zwick, Harry

    2004-07-01

    This study examined the role of oxidative stress and the effect of a single dose treatment with N-Acetylcysteine (NAC) on the temporal development of acute laser-induced retinal injury. We used the snake eye/Scanning Laser Ophthalmoscope (SLO) model, an in vivo, non-invasive ocular imaging technique, which has the ability to image cellular retinal detail and allows for studying morphological changes of retinal injury over time. For this study 12 corn-snakes (Elaphe g. guttata) received 5 laser exposures per eye, followed by either a single dose of the antioxidant NAC (150mg/kg, IP in sterile saline) or placebo. Laser exposures were made with a Nd: VO4 DPSS, 532nm laser, coaxially aligned to the SLO. Shuttered pulses were 20msec x 50 mW; 1mJ each. Retinal images were taken using a Rodenstock cSLO and were digitally recorded at 1, 6, 24-hrs, and at 3-wks post-exposure. Lesions were assessed by two raters blind to the conditions of the study yielding measures of damaged area and counts of missing or damaged photoreceptors. Treated eyes showed a significant beneficial effect overall, and these results suggest that oxidative stress plays a role in laser-induced retinal injury. The use of NAC or a similar antioxidant shows promise as a therapeutic tool.

  9. Control system for several rotating mirror camera synchronization operation

    NASA Astrophysics Data System (ADS)

    Liu, Ningwen; Wu, Yunfeng; Tan, Xianxiang; Lai, Guoji

    1997-05-01

    This paper introduces a single chip microcomputer control system for synchronization operation of several rotating mirror high-speed cameras. The system consists of four parts: the microcomputer control unit (including the synchronization part and precise measurement part and the time delay part), the shutter control unit, the motor driving unit and the high voltage pulse generator unit. The control system has been used to control the synchronization working process of the GSI cameras (driven by a motor) and FJZ-250 rotating mirror cameras (driven by a gas driven turbine). We have obtained the films of the same objective from different directions in different speed or in same speed.

  10. Sunlight-switchable light shutter fabricated using liquid crystals doped with push-pull azobenzene.

    PubMed

    Oh, Seung-Won; Baek, Jong-Min; Yoon, Tae-Hoon

    2016-11-14

    We propose a sunlight-switchable light shutter using liquid crystal/polymer composite doped with push-pull azobenzene. The proposed light shutter is switchable between the translucent and transparent states by application of an electric field or by UV irradiation. Switching by UV irradiation is based on the change of the liquid crystal (LC) clearing point by the photo-isomerization effect of push-pull azobenzene. Under sunlight, the light shutter can be switched from the translucent to the transparent state by the nematic-isotropic phase transition of the LC domains triggered by trans-cis photo-isomerization of the push-pull azobenzene molecules. When the amount of sunlight is low because of cloud cover or when there is no sunlight at sunset, the light shutter rapidly relaxes from its transparent state back to its initial translucent state by the isotropic-nematic phase transition induced by cis-trans back-isomerization of the push-pull azobenzene molecules.

  11. Development of Gentle Slope Light Guide Structure in a 3.4 μm Pixel Pitch Global Shutter CMOS Image Sensor with Multiple Accumulation Shutter Technology.

    PubMed

    Sekine, Hiroshi; Kobayashi, Masahiro; Onuki, Yusuke; Kawabata, Kazunari; Tsuboi, Toshiki; Matsuno, Yasushi; Takahashi, Hidekazu; Inoue, Shunsuke; Ichikawa, Takeshi

    2017-12-09

    CMOS image sensors (CISs) with global shutter (GS) function are strongly required in order to avoid image degradation. However, CISs with GS function have generally been inferior to the rolling shutter (RS) CIS in performance, because they have more components. This problem is remarkable in small pixel pitch. The newly developed 3.4 µm pitch GS CIS solves this problem by using multiple accumulation shutter technology and the gentle slope light guide structure. As a result, the developed GS pixel achieves 1.8 e - temporal noise and 16,200 e - full well capacity with charge domain memory in 120 fps operation. The sensitivity and parasitic light sensitivity are 28,000 e - /lx·s and -89 dB, respectively. Moreover, the incident light angle dependence of sensitivity and parasitic light sensitivity are improved by the gentle slope light guide structure.

  12. Multichannel optical sensing device

    DOEpatents

    Selkowitz, S.E.

    1985-08-16

    A multichannel optical sensing device is disclosed, for measuring the outdoor sky luminance or illuminance or the luminance or illuminance distribution in a room, comprising a plurality of light receptors, an optical shutter matrix including a plurality of liquid crystal optical shutter elements operable by electrical control signals between light transmitting and light stopping conditions, fiber optical elements connected between the receptors and the shutter elements, a microprocessor based programmable control unit for selectively supplying control signals to the optical shutter elements in a programmable sequence, a photodetector including an optical integrating spherical chamber having an input port for receiving the light from the shutter matrix and at least one detector element in the spherical chamber for producing output signals corresponding to the light, and output units for utilizing the output signals including a storage unit having a control connection to the microprocessor based programmable control unit for storing the output signals under the sequence control of the programmable control unit.

  13. Multichannel optical sensing device

    DOEpatents

    Selkowitz, Stephen E.

    1990-01-01

    A multichannel optical sensing device is disclosed, for measuring the outr sky luminance or illuminance or the luminance or illuminance distribution in a room, comprising a plurality of light receptors, an optical shutter matrix including a plurality of liquid crystal optical shutter elements operable by electrical control signals between light transmitting and light stopping conditions, fiber optic elements connected between the receptors and the shutter elements, a microprocessor based programmable control unit for selectively supplying control signals to the optical shutter elements in a programmable sequence, a photodetector including an optical integrating spherical chamber having an input port for receiving the light from the shutter matrix and at least one detector element in the spherical chamber for producing output signals corresponding to the light, and output units for utilizing the output signals including a storage unit having a control connection to the microprocessor based programmable control unit for storing the output signals under the sequence control of the programmable control unit.

  14. Ultra-fast high-resolution hybrid and monolithic CMOS imagers in multi-frame radiography

    NASA Astrophysics Data System (ADS)

    Kwiatkowski, Kris; Douence, Vincent; Bai, Yibin; Nedrow, Paul; Mariam, Fesseha; Merrill, Frank; Morris, Christopher L.; Saunders, Andy

    2014-09-01

    A new burst-mode, 10-frame, hybrid Si-sensor/CMOS-ROIC FPA chip has been recently fabricated at Teledyne Imaging Sensors. The intended primary use of the sensor is in the multi-frame 800 MeV proton radiography at LANL. The basic part of the hybrid is a large (48×49 mm2) stitched CMOS chip of 1100×1100 pixel count, with a minimum shutter speed of 50 ns. The performance parameters of this chip are compared to the first generation 3-frame 0.5-Mpixel custom hybrid imager. The 3-frame cameras have been in continuous use for many years, in a variety of static and dynamic experiments at LANSCE. The cameras can operate with a per-frame adjustable integration time of ~ 120ns-to- 1s, and inter-frame time of 250ns to 2s. Given the 80 ms total readout time, the original and the new imagers can be externally synchronized to 0.1-to-5 Hz, 50-ns wide proton beam pulses, and record up to ~1000-frame radiographic movies typ. of 3-to-30 minute duration. The performance of the global electronic shutter is discussed and compared to that of a high-resolution commercial front-illuminated monolithic CMOS imager.

  15. AUTOMOTIVE DIESEL MAINTENANCE 1. UNIT XIII, I--MAINTAINING THE FUEL SYSTEM (PART III), CUMMINS DIESEL ENGINES, II--RADIATOR SHUTTER SYSTEM.

    ERIC Educational Resources Information Center

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 30-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE CONSTRUCTION, OPERATION, AND MAINTENANCE OF THE DIESEL ENGINE FUEL AND RADIATOR SHUTTER SYSTEMS. TOPICS ARE (1) MORE ABOUT THE CUMMINS FUEL SYSTEM, (2) CALIBRATING THE PT FUEL PUMP, (3) CALIBRATING THE FUEL INJECTORS, (4) UNDERSTANDING THE SHUTTER SYSTEM, (5) THE…

  16. Pulsed rotating supersonic source for merged molecular beams

    NASA Astrophysics Data System (ADS)

    Sheffield, L.; Hickey, M. S.; Krasovitskiy, V.; Rathnayaka, K. D. D.; Lyuksyutov, I. F.; Herschbach, D. R.

    2012-06-01

    We describe a pulsed rotating supersonic beam source, evolved from an ancestral device [M. Gupta and D. Herschbach, J. Phys. Chem. A 105, 1626 (2001)]. The beam emerges from a nozzle near the tip of a hollow rotor which can be spun at high-speed to shift the molecular velocity distribution downward or upward over a wide range. Here we consider mostly the slowing mode. Introducing a pulsed gas inlet system, cryocooling, and a shutter gate eliminated the main handicap of the original device in which continuous gas flow imposed high background pressure. The new version provides intense pulses, of duration 0.1-0.6 ms (depending on rotor speed) and containing ˜1012 molecules at lab speeds as low as 35 m/s and ˜1015 molecules at 400 m/s. Beams of any molecule available as a gas can be slowed (or speeded); e.g., we have produced slow and fast beams of rare gases, O2, Cl2, NO2, NH3, and SF6. For collision experiments, the ability to scan the beam speed by merely adjusting the rotor is especially advantageous when using two merged beams. By closely matching the beam speeds, very low relative collision energies can be attained without making either beam very slow.

  17. Pulsed rotating supersonic source for merged molecular beams

    NASA Astrophysics Data System (ADS)

    Sheffield, Les; Hickey, Mark; Krasovitskiy, Vitaliy; Rathnayaka, Daya; Lyuksyutov, Igor; Herschbach, Dudley

    2012-10-01

    We continue the characterization of a pulsed rotating supersonic beam source. The original device was described by M. Gupta and D. Herschbach, J. Phys. Chem. A 105, 1626 (2001). The beam emerges from a nozzle near the tip of a hollow rotor which can be spun at high-speed to shift the molecular velocity distribution downward or upward over a wide range. Here we consider mostly the slowing mode. Introducing a pulsed gas inlet system, and a shutter gate eliminate the main handicap of the original device in which continuous gas flow imposed high background pressure. The new version provides intense pulses, of duration 0.1--0.6 ms (depending on rotor speed) and containing ˜10^12 molecules at lab speeds as low as 35 m/s and ˜10^15 molecules at 400 m/s. Beams of any molecule available as a gas can be slowed (or speeded); e.g., we have produced slow and fast beams of rare gases, O2, NO2, NH3, and SF6. For collision experiments, the ability to scan the beam speed by merely adjusting the rotor is especially advantageous when using two merged beams. By closely matching the beam speeds, very low relative collision energies can be attained without making either beam very slow.

  18. Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) onboard calibration system

    NASA Technical Reports Server (NTRS)

    Chrien, Thomas G.; Eastwood, Mike; Green, Robert O.; Sarture, Charles; Johnson, Howell; Chovit, Chris; Hajek, Pavel

    1995-01-01

    The AVIRIS instrument uses an onboard calibration system to provide auxiliary calibration data. The system consist of a tungsten halogen cycle lamp imaged onto a fiber bundle through an eight position filter wheel. The fiber bundle illuminates the back side of the foreoptics shutter during a pre-run and post-run calibration sequence. The filter wheel contains two neutral density filters, five spectral filters and one blocked position. This paper reviews the general workings of the onboard calibrator system and discusses recent modifications.

  19. Manipulation of morphology and structure of the top of GaAs nanowires grown by molecular-beam epitaxy

    NASA Astrophysics Data System (ADS)

    Li, Lixia; Pan, Dong; Yu, Xuezhe; So, Hyok; Zhao, Jianhua

    2017-10-01

    Self-catalyzed GaAs nanowires (NWs) are grown on Si (111) substrates by molecular-beam epitaxy. The effect of different closing sequences of the Ga and As cell shutters on the morphology and structural phase of GaAs NWs is investigated. For the sequences of closing the Ga and As cell shutters simultaneously or closing the As cell shutter 1 min after closing the Ga cell shutter, the NWs grow vertically to the substrate surface. In contrast, when the As cell shutter is closed first, maintaining the Ga flux is found to be critical for the following growth of GaAs NWs, which can change the growth direction from [111] to < 11\\bar{1}> . The evolution of the morphology and structural phase transition at the tips of these GaAs NWs confirm that the triple-phase-line shift mode is at work even for the growth with different cell shutter closing sequences. Our work will provide new insights for better understanding of the growth mechanism and realizing of the morphology and structure control of the GaAs NWs. Project supported partly by the MOST of China (No. 2015CB921503), the National Natural Science Foundation of China (Nos. 61504133, 61334006, 61404127), and Youth Innovation Promotion Association, CAS (No. 2017156).

  20. Laser synchronized high-speed shutter for spectroscopic application

    DOEpatents

    Miles, Paul C.; Porter, Eldon L.; Prast, Thomas L.; Sunnarborg, Duane A.

    2002-01-01

    A fast mechanical shutter, based on rotating chopper wheels, has been designed and implemented to shutter the entrance slit of a spectrograph. This device enables an exposure time of 9 .mu.s to be achieved for a 0.8 mm wide spectrograph entrance slit, achieves 100% transmission in the open state, and an essentially infinite extinction ratio. The device further incorporates chopper wheel position sensing electronics to permit the synchronous triggering of a laser source.

  1. Roof aperture system for selective collection and control of solar energy for building heating, cooling and daylighting

    DOEpatents

    Sanders, William J.; Snyder, Marvin K.; Harter, James W.

    1983-01-01

    The amount of building heating, cooling and daylighting is controlled by at least one pair of solar energy passing panels, with each panel of the pair of panels being exposed to a separate direction of sun incidence. A shutter-shade combination is associated with each pair of panels and the shutter is connected to the shade so that rectilinear movement of the shutter causes pivotal movement of the shade.

  2. a Novel Technique for Precision Geometric Correction of Jitter Distortion for the Europa Imaging System and Other Rolling-Shutter Cameras

    NASA Astrophysics Data System (ADS)

    Kirk, R. L.; Shepherd, M.; Sides, S. C.

    2018-04-01

    We use simulated images to demonstrate a novel technique for mitigating geometric distortions caused by platform motion ("jitter") as two-dimensional image sensors are exposed and read out line by line ("rolling shutter"). The results indicate that the Europa Imaging System (EIS) on NASA's Europa Clipper can likely meet its scientific goals requiring 0.1-pixel precision. We are therefore adapting the software used to demonstrate and test rolling shutter jitter correction to become part of the standard processing pipeline for EIS. The correction method will also apply to other rolling-shutter cameras, provided they have the operational flexibility to read out selected "check lines" at chosen times during the systematic readout of the frame area.

  3. Structural Analysis of a Magnetically Actuated Silicon Nitride Micro-Shutter for Space Applications

    NASA Technical Reports Server (NTRS)

    Loughlin, James P.; Fettig, Rainer K.; Moseley, S. Harvey; Kutyrev, Alexander S.; Mott, D. Brent; Obenschain, Arthur F. (Technical Monitor)

    2002-01-01

    Finite element models have been created to simulate the electrostatic and electromagnetic actuation of a 0.5 micrometers silicon nitride micro-shutter for use in a spacebased Multi-object Spectrometer (MOS). The microshutter uses a torsion hinge to go from the closed, 0 degree, position, to the open, 90 degree position. Stresses in the torsion hinge are determined with a large deformation nonlinear finite element model. The simulation results are compared to experimental measurements of fabricated micro-shutter devices.

  4. Active pixel sensor array with electronic shuttering

    NASA Technical Reports Server (NTRS)

    Fossum, Eric R. (Inventor)

    2002-01-01

    An active pixel cell includes electronic shuttering capability. The cell can be shuttered to prevent additional charge accumulation. One mode transfers the current charge to a storage node that is blocked against accumulation of optical radiation. The charge is sampled from a floating node. Since the charge is stored, the node can be sampled at the beginning and the end of every cycle. Another aspect allows charge to spill out of the well whenever the charge amount gets higher than some amount, thereby providing anti blooming.

  5. Internal combustion engine with rotary valve assembly having variable intake valve timing

    DOEpatents

    Hansen, Craig N.; Cross, Paul C.

    1995-01-01

    An internal combustion engine has rotary valves associated with movable shutters operable to vary the closing of intake air/fuel port sections to obtain peak volumetric efficiency over the entire range of speed of the engine. The shutters are moved automatically by a control mechanism that is responsive to the RPM of the engine. A foot-operated lever associated with the control mechanism is also used to move the shutters between their open and closed positions.

  6. Shutter mechanism for spacecraft spectrophotometer

    NASA Technical Reports Server (NTRS)

    Weilbach, A.

    1972-01-01

    A shutter mechanism is described for the backscatter ultraviolet spectrophotometer experiment on the Nimbus D satellite. The purpose of the experiment is to determine spatial distribution of atmospheric ozone from measurements of ultraviolet radiation backscattered by the earth's atmosphere. The system consists of two independent, rotary cylinder shutters, controlled by a dual star Geneva mechanism, and driven by a single stepper motor. A single driver controls a combination of two independently driven Geneva stars. Design considerations involved the use of low friction, nonmetallic materials.

  7. A Low Power Cryogenic Shutter Mechanism for use in Infrared Images

    NASA Technical Reports Server (NTRS)

    Schwinger, D. Scott; Hakun, Claef F.

    2000-01-01

    This paper discusses the requirements, design, operation, and testing of the shutter mechanism for the Infrared Array Camera (IRAC). The shutter moves a mirror panel into or out of the incoming light path transitioning IRAC between data acquisition and calibration modes. The mechanism features a torsion flexure suspension system, two low-power rotary actuators, a balanced shaft, and a variable reluctance position sensor. Each of these items is discussed along with problems encountered during development and the implemented solutions.

  8. New Developments of Broadband Cavity Enhanced Spectroscopic Techniques

    NASA Astrophysics Data System (ADS)

    Walsh, A.; Zhao, D.; Linnartz, H.; Ubachs, W.

    2013-06-01

    In recent years, cavity enhanced spectroscopic techniques, such as cavity ring-down spectroscopy (CRDS), cavity enhanced absorption spectroscopy (CEAS), and broadband cavity enhanced absorption spectroscopy (BBCEAS), have been widely employed as ultra-sensitive methods for the measurement of weak absorptions and in the real-time detection of trace species. In this contribution, we introduce two new cavity enhanced spectroscopic concepts: a) Optomechanical shutter modulated BBCEAS, a variant of BBCEAS capable of measuring optical absorption in pulsed systems with typically low duty cycles. In conventional BBCEAS applications, the latter substantially reduces the signal-to-noise ratio (S/N), consequently also reducing the detection sensitivity. To overcome this, we incorporate a fast optomechanical shutter as a time gate, modulating the detection scheme of BBCEAS and increasing the effective duty cycle reaches a value close to unity. This extends the applications of BBCEAS into pulsed samples and also in time-resolved studies. b) Cavity enhanced self-absorption spectroscopy (CESAS), a new spectroscopic concept capable of studying light emitting matter (plasma, flames, combustion samples) simultaneously in absorption and emission. In CESAS, a sample (plasma, flame or combustion source) is located in an optically stable cavity consisting of two high reflectivity mirrors, and here it acts both as light source and absorbing medium. A high detection sensitivity of weak absorption is reached without the need of an external light source, such as a laser or broadband lamp. The performance is illustrated by the first CESAS result on a supersonically expanding hydrocarbon plasma. We expect CESAS to become a generally applicable analytical tool for real time and in situ diagnostics. A. Walsh, D. Zhao, W. Ubachs, H. Linnartz, J. Phys. Chem. A, {dx.doi.org/10.1021/jp310392n}, in press, 2013. A. Walsh, D. Zhao, H. Linnartz Rev. Sci. Instrum. {84}(2), 021608 2013. A. Walsh, D. Zhao, H. Linnartz Appl. Phys. Lett. {101}(9), 091111 2012.

  9. 6. DETAIL EXTERIOR VIEW OF WINDOW SHUTTERS ON OUTSIDE OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. DETAIL EXTERIOR VIEW OF WINDOW SHUTTERS ON OUTSIDE OF FISH HATCHERY BUILDING. - Bonneville Project, Fish Hatchery, On Columbia River bordered on South by Union Pacific, Bonneville, Multnomah County, OR

  10. Electronic trigger for capacitive touchscreen and extension of ISO 15781 standard time lag measurements to smartphones

    NASA Astrophysics Data System (ADS)

    Bucher, François-Xavier; Cao, Frédéric; Viard, Clément; Guichard, Frédéric

    2014-03-01

    We present in this paper a novel capacitive device that stimulates the touchscreen interface of a smartphone (or of any imaging device equipped with a capacitive touchscreen) and synchronizes triggering with the DxO LED Universal Timer to measure shooting time lag and shutter lag according to ISO 15781:2013. The device and protocol extend the time lag measurement beyond the standard by including negative shutter lag, a phenomenon that is more and more commonly found in smartphones. The device is computer-controlled, and this feature, combined with measurement algorithms, makes it possible to automatize a large series of captures so as to provide more refined statistical analyses when, for example, the shutter lag of "zero shutter lag" devices is limited by the frame time as our measurements confirm.

  11. IR Sensor Synchronizing Active Shutter Glasses for 3D HDTV with Flexible Liquid Crystal Lenses

    PubMed Central

    Han, Jeong In

    2013-01-01

    IR sensor synchronizing active shutter glasses for three-dimensional high definition television (3D HDTV) were developed using a flexible liquid crystal (FLC) lens. The FLC lens was made on a polycarbonate (PC) substrate using conventional liquid crystal display (LCD) processes. The flexible liquid crystal lens displayed a maximum transmission of 32% and total response time of 2.56 ms. The transmittance, the contrast ratio and the response time of the flexible liquid crystal lens were superior to those of glass liquid crystal lenses. Microcontroller unit and drivers were developed as part of a reception module with power supply for the IR sensor synchronizing active shutter glasses with the flexible liquid crystal lens prototypes. IR sensor synchronizing active shutter glasses for 3D HDTV with flexible liquid crystal lenses produced excellent 3D images viewing characteristics.

  12. Development of a drive system for a sequential space camera

    NASA Technical Reports Server (NTRS)

    Sharpsteen, J. T.; Solheim, C. D.; Stoap, L. J.

    1976-01-01

    An electronically commutated dc motor is reported for driving the camera claw and magazine, and a stepper motor is described for driving the shutter with the two motors synchronized electrically. Subsequent tests on the breadboard positively proved the concept, but further development beyond this study should be done. The breadboard testing also established that the electronically commutated motor can control speed over a wide dynamic range, and has a high torque capability for accelerating loads. This performance suggested the possibility of eliminating the clutch from the system while retaining all of the other mechanical features of the DAC, if the requirement for independent shutter speeds and frame rates can be removed. Therefore, as a final step in the study, the breadboard shutter and shutter drive were returned to the original DAC configuration, while retaining the brushless dc motor drive.

  13. Piezo-Operated Shutter Mechanism Moves 1.5 cm

    NASA Technical Reports Server (NTRS)

    Glaser, Robert; Bamford, Robert

    2005-01-01

    The figure shows parts of a shutter mechanism designed to satisfy a number of requirements specific to its original intended application as a component of an atomic clock to be flown in outer space. The mechanism may also be suitable for use in laboratory and industrial vacuum systems on Earth for which there are similar requirements. The requirements include the following: a) To alternately close, then open, a 1.5-cm-diameter optical aperture twice per second, with a stroke time of no more than 15 ms, during a total operational lifetime of at least a year; b) To attenuate light by a factor of at least 1012 when in the closed position; c) To generate little or no magnetic field; d) To be capable of withstanding bakeout at a temperature of 200 C to minimize outgassing during subsequent operation in an ultrahigh vacuum; and e) To fit within a diameter of 12 in. (=305 mm) a size limit dictated by the size of an associated magnetic shield. The light-attenuation requirement is satisfied by use of overlapping shutter blades. The closure of the aperture involves, among other things, insertion of a single shutter blade between a pair of shutter blades. The requirement to minimize the magnetic field is satisfied by use of piezoelectric actuators. Because piezoelectric actuators cannot withstand bakeout, they must be mounted outside the vacuum chamber, and, hence, motion must be transmitted from the actuators to the shutter levers via a vacuum-chamber-wall diaphragm.

  14. FEM and Multiphysics Applications at NASA/GSFC

    NASA Technical Reports Server (NTRS)

    Loughlin, James

    2004-01-01

    FEM software available to the Mechanical Systems Analysis and Simulation Branch at Goddard Space Flight Center (GSFC) include: 1) MSC/Nastran; 2) Abaqus; 3) Ansys/Multiphysics; 4) COSMOS/M; 5) 'Home-grown' programs; 6) Pre/post processors such as Patran and FEMAP. This viewgraph presentation provides additional information on MSC/Nastran and Ansys/Multiphysics, and includes screen shots of analyzed equipment, including the Wilkinson Microwave Anistropy Probe, a micro-mirror, a MEMS tunable filter, and a micro-shutter array. The presentation also includes information on the verification of results.

  15. 10. SAME DETAIL AS ABOVE, WITH SHUTTER FULLY CLOSED 11. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. SAME DETAIL AS ABOVE, WITH SHUTTER FULLY CLOSED 11. 'SHIP ROOM,' SECOND FLOOR, LOOKING NORTHWEST 12. 'SHIP ROOM,' SECOND FLOOR, LOOKING NORTH - Friends Meeting House, 30 Farewell Street, Newport, Newport County, RI

  16. Designing the optimal shutter sequences for the flutter shutter imaging method

    NASA Astrophysics Data System (ADS)

    Jelinek, Jan

    2010-04-01

    Acquiring iris or face images of moving subjects at larger distances using a flash to prevent the motion blur quickly runs into eye safety concerns as the acquisition distance is increased. For that reason the flutter shutter method recently proposed by Raskar et al.has generated considerable interest in the biometrics community. The paper concerns the design of shutter sequences that produce the best images. The number of possible sequences grows exponentially in both the subject' s motion velocity and desired exposure value, with their majority being useless. Because the exact solution leads to an intractable mixed integer programming problem, we propose an approximate solution based on pre - screening the sequences according to the distribution of roots in their Fourier transform. A very fast algorithm utilizing the Jury' s criterion allows the testing to be done without explicitly computing the roots, making the approach practical for moderately long sequences.

  17. Micro-optical system based 3D imaging for full HD depth image capturing

    NASA Astrophysics Data System (ADS)

    Park, Yong-Hwa; Cho, Yong-Chul; You, Jang-Woo; Park, Chang-Young; Yoon, Heesun; Lee, Sang-Hun; Kwon, Jong-Oh; Lee, Seung-Wan

    2012-03-01

    20 Mega-Hertz-switching high speed image shutter device for 3D image capturing and its application to system prototype are presented. For 3D image capturing, the system utilizes Time-of-Flight (TOF) principle by means of 20MHz high-speed micro-optical image modulator, so called 'optical shutter'. The high speed image modulation is obtained using the electro-optic operation of the multi-layer stacked structure having diffractive mirrors and optical resonance cavity which maximizes the magnitude of optical modulation. The optical shutter device is specially designed and fabricated realizing low resistance-capacitance cell structures having small RC-time constant. The optical shutter is positioned in front of a standard high resolution CMOS image sensor and modulates the IR image reflected from the object to capture a depth image. Suggested novel optical shutter device enables capturing of a full HD depth image with depth accuracy of mm-scale, which is the largest depth image resolution among the-state-of-the-arts, which have been limited up to VGA. The 3D camera prototype realizes color/depth concurrent sensing optical architecture to capture 14Mp color and full HD depth images, simultaneously. The resulting high definition color/depth image and its capturing device have crucial impact on 3D business eco-system in IT industry especially as 3D image sensing means in the fields of 3D camera, gesture recognition, user interface, and 3D display. This paper presents MEMS-based optical shutter design, fabrication, characterization, 3D camera system prototype and image test results.

  18. SECOND FLOOR FRONT ROOM, WINDOWS FACING ON WALNUT STREET (SOUTH), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SECOND FLOOR FRONT ROOM, WINDOWS FACING ON WALNUT STREET (SOUTH), ORIGINAL PANELED FOLDING SHUTTERS AND HARDWARE. For a view of closed shutters see PA-1436 A-16 - Kid-Chandler House, 323 Walnut Street, Philadelphia, Philadelphia County, PA

  19. 13. Detail, typical window with fireproof shutters closed, northeast rear, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. Detail, typical window with fireproof shutters closed, northeast rear, view to southwest, 135mm lens. Note cracks evidencing structural failure. - Benicia Arsenal, Powder Magazine No. 5, Junction of Interstate Highways 680 & 780, Benicia, Solano County, CA

  20. 12. Detail, typical window with fireproof shutters open, northeast rear, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Detail, typical window with fireproof shutters open, northeast rear, view to southwest, 135mm lens. Note cracks evidencing structural failure. - Benicia Arsenal, Powder Magazine No. 5, Junction of Interstate Highways 680 & 780, Benicia, Solano County, CA

  1. MEMS Microshutter Array System for James Webb Space Telescope

    NASA Technical Reports Server (NTRS)

    Li, Mary J.; Adachi, Tomoko; Allen, Christine; Babu, Sachi; Bajikar, Sateesh; Beamesderfer, Michael; Bradley, Ruth; Denis, Kevin; Costen, Nick; Ewin, Audrey; hide

    2008-01-01

    A complex MEMS microshutter array system has been developed at NASA Goddard Space Flight Center (GSFC) for use as a multi-object aperture array for a Near-Infrared Spectrometer (NIRSpec). The NIRSpec is one of the four major instruments carried by the James Webb Space Telescope (JWST), the next generation of space telescope after the Hubble Space Telescope retires. The microshutter arrays (MSAs) are designed for the selective transmission of light with high efficiency and high contrast. It is demonstrated in Figure 1 how a MSA is used as a multiple object selector in deep space. The MSAs empower the NIRSpec instrument simultaneously collect spectra from more than 100 targets therefore increases the instrument efficiency 100 times or more. The MSA assembly is one of three major innovations on JWST and the first major MEMS devices serving observation missions in space. The MSA system developed at NASA GSFC is assembled with four quadrant fully addressable 365x171 shutter arrays that are actuated magnetically, latched and addressed electrostatically. As shown in Figure 2, each MSA is fabricated out of a 4' silicon-on-insulator (SOI) wafer using MEMS bulk-micromachining technology. Individual shutters are close-packed silicon nitride membranes with a pixel size close to 100x200 pm (Figure 3). Shutters are patterned with a torsion flexure permitting shutters to open 90 degrees with a minimized mechanical stress concentration. In order to prevent light leak, light shields are made on to the surrounding frame of each shutter to cover the gaps between the shutters and the Game (Figure 4). Micro-ribs and sub-micron bumps are tailored on hack walls and light shields, respectively, to prevent sticktion, shown in Figures 4 and 5. JWST instruments are required to operate at cryogenic temperatures as low as 35K, though they are to be subjected to various levels of ground tests at room temperature. The shutters should therefore maintain nearly flat in the entire temperature range between 35K and 300K. Through intensive numerical simulations and experimental studies, an optically opaque and electrically conductive metal-nitride thin film was selected as a coating material deposited on the shutters with the best thermal-expansion match to silicon nitride - the shutter blade thin film material. A shutter image shown in Figure 6 was taken at room temperature, presenting shutters slightly bowing down as expected. Shutters become flat when the temperature decreases to 35K. The MSAs are then bonded to silicon substrates that are fabricated out of 6" single-silicon wafers in the thickness of 2mm. The bonding is conducted using a novel single-sided indium flip-chip bonding technology. Indium bumps fabricated on a substrate are shown in Figure 7. There are 180,000 indium bumps for bonding a flight format MSA array to its substrate. Besides a MSA, each substrate houses five customer-designed ASIC (Application Specific Integrated Circuit) multiplexer/address chips for 2-dimensional addressing, twenty capacitors, two temperature sensors, numbers of resistors and all necessary interconnects, as shown in Figure 8. Complete MSA quadrant assemblies have been successfully manufactured and fully functionally tested. The assemblies have passed a series of critical reviews required by JWST in satisfying all the design specifications. The qualification tests cover programmable 2-D addressing, life tests, optical contrast tests, and environmental tests including radiation, vibration, and acoustic tests. A 2-D addressing pattern with 'ESA' letters programmed in a MSA is shown in Figure 9. The MSAs passed 1 million cycle life tests and achieved high optical contrast over 10,000. MSA teams are now making progress in final fabrication, testing and assembly (Figure 10). The delivery of flight-format MSA system is scheduled at the end of 2008 for being integrated to the focal plane of the NIRSpec detectors.

  2. WINDOW WITH ORIGINAL PANELED FOLDING SHUTTERS, SECOND FLOOR FRONT ROOM, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    WINDOW WITH ORIGINAL PANELED FOLDING SHUTTERS, SECOND FLOOR FRONT ROOM, LOOKING OUT WALNUT STREET (SOUTH). NOTE ALTERED LOWER SECTION MADE CA. 1840. Compare window in PA-1436 A-37 - Kid-Chandler House, 323 Walnut Street, Philadelphia, Philadelphia County, PA

  3. ISOTOPE SEPARATORS

    DOEpatents

    Bacon, C.G.

    1958-08-26

    An improvement is presented in the structure of an isotope separation apparatus and, in particular, is concerned with a magnetically operated shutter associated with a window which is provided for the purpose of enabling the operator to view the processes going on within the interior of the apparatus. The shutier is mounted to close under the force of gravity in the absence of any other force. By closing an electrical circuit to a coil mouated on the shutter the magnetic field of the isotope separating apparatus coacts with the magnetic field of the coil to force the shutter to the open position.

  4. New simulation and measurement results on gateable DEPFET devices

    NASA Astrophysics Data System (ADS)

    Bähr, Alexander; Aschauer, Stefan; Hermenau, Katrin; Herrmann, Sven; Lechner, Peter H.; Lutz, Gerhard; Majewski, Petra; Miessner, Danilo; Porro, Matteo; Richter, Rainer H.; Schaller, Gerhard; Sandow, Christian; Schnecke, Martina; Schopper, Florian; Stefanescu, Alexander; Strüder, Lothar; Treis, Johannes

    2012-07-01

    To improve the signal to noise level, devices for optical and x-ray astronomy use techniques to suppress background events. Well known examples are e.g. shutters or frame-store Charge Coupled Devices (CCDs). Based on the DEpleted P-channel Field Effect Transistor (DEPFET) principle a so-called Gatebale DEPFET detector can be built. Those devices combine the DEPFET principle with a fast built-in electronic shutter usable for optical and x-ray applications. The DEPFET itself is the basic cell of an active pixel sensor build on a fully depleted bulk. It combines internal amplification, readout on demand, analog storage of the signal charge and a low readout noise with full sensitivity over the whole bulk thickness. A Gatebale DEPFET has all these benefits and obviates the need for an external shutter. Two concepts of Gatebale DEPFET layouts providing a built-in shutter will be introduced. Furthermore proof of principle measurements for both concepts are presented. Using recently produced prototypes a shielding of the collection anode up to 1 • 10-4 was achieved. Predicted by simulations, an optimized geometry should result in values of 1 • 10-5 and better. With the switching electronic currently in use a timing evaluation of the shutter opening and closing resulted in rise and fall times of 100ns.

  5. An efficient shutter-less non-uniformity correction method for infrared focal plane arrays

    NASA Astrophysics Data System (ADS)

    Huang, Xiyan; Sui, Xiubao; Zhao, Yao

    2017-02-01

    The non-uniformity response in infrared focal plane array (IRFPA) detectors has a bad effect on images with fixed pattern noise. At present, it is common to use shutter to prevent from radiation of target and to update the parameters of non-uniformity correction in the infrared imaging system. The use of shutter causes "freezing" image. And inevitably, there exists the problems of the instability and reliability of system, power consumption, and concealment of infrared detection. In this paper, we present an efficient shutter-less non-uniformity correction (NUC) method for infrared focal plane arrays. The infrared imaging system can use the data gaining in thermostat to calculate the incident infrared radiation by shell real-timely. And the primary output of detector except the shell radiation can be corrected by the gain coefficient. This method has been tested in real infrared imaging system, reaching high correction level, reducing fixed pattern noise, adapting wide temperature range.

  6. Delay time in a single barrier for a movable quantum shutter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernandez, Alberto

    2010-05-15

    The transient solution and delay time for a {delta} potential scatterer with a movable quantum shutter is calculated by solving analytically the time-dependent Schroedinger equation. The delay time is analyzed as a function of the distance between the shutter and the potential barrier and also as a function of the distance between the potential barrier and the detector. In both cases, it is found that the delay time exhibits a dynamical behavior and that it tends to a saturation value {Delta}t{sub sat} in the limit of very short distances, which represents the maximum delay produced by the potential barrier nearmore » the interaction region. The phase time {tau}{sub {theta},} on the other hand, is not an appropriate time scale for measuring the time delay near the interaction region, except if the shutter is moved far away from the potential. The role played by the antibound state of the system on the behavior of the delay time is also discussed.« less

  7. An Experimental Characterization System for Deep Ultra-Violet (UV) Photoresists

    NASA Astrophysics Data System (ADS)

    Drako, Dean M.; Partlo, William N.; Oldham, William G.; Neureuther, Andrew R.

    1989-08-01

    A versatile system designed specifically for experimental automated photoresist characterization has been constructed utilizing an excimer laser source for exposure at 248nm. The system was assembled, as much as possible, from commercially available components in order to facilitate its replication. The software and hardware are completely documented in a University of California-Berkeley Engineering Research Lab Memo. An IBM PC-AT compatible computer controls an excimer laser, operates a Fourier Transform Infrared (FTIR) Spectrometer, measures and records the energy of each laser pulse (incident, reflected, and transmitted), opens and closes shutters, and operates two linear stages for sample movement. All operations (except FTIR data reduction) are managed by a control program written in the "C" language. The system is capable of measuring total exposure dose, performing bleaching measurements, creating and recording exposure pulse sequences, and generating exposure patterns suitable for multiple channel monitoring of the development. The total exposure energy, energy per pulse, and pulse rate are selectable over a wide range. The system contains an in-situ Fourier Transform Infrared Spectrometer for qualitative and quantitative analysis of the photoresist baking and exposure processes (baking is not done in-situ). FIIR may be performed in transmission or reflection. The FTIR data will form the basis of comprehensive multi-state resist models. The system's versatility facilitates the development of new automated and repeatable experiments. Simple controlling software, utilizing the provided interface sub-routines, can be written to control new experiments and collect data.

  8. Fabrication of a dye-doped liquid crystal light shutter by thermal curing of polymer

    NASA Astrophysics Data System (ADS)

    Yu, Byeong-Hun; Ji, Seong-Min; Kim, Jin-Hun; Huh, Jae-Won; Yoon, Tae-Hoon

    2017-07-01

    We report a thermal curing method for fabrication of a dye-doped polymer-stabilized liquid crystal (PSLC) light shutter, which can prevent the decrease in absorption and discoloration of the dye caused by the UV curing process. We found that the measured transmittance in the opaque state of a dye-doped PSLC cell fabricated by thermal curing was approximately 35% lower than that of a dye-doped PSLC cell fabricated by UV curing. Thermal curing can be an alternative approach for fabrication of a dye-doped PSLC light shutter which can be used to provide high visibility of a see-through display.

  9. Development of fire shutters based on numerical optimizations

    NASA Astrophysics Data System (ADS)

    Novak, Ondrej; Kulhavy, Petr; Martinec, Tomas; Petru, Michal; Srb, Pavel

    2018-06-01

    This article deals with a prototype concept, real experiment and numerical simulation of a layered industrial fire shutter, based on some new insulating composite materials. The real fire shutter has been developed and optimized in laboratory and subsequently tested in the certified test room. A simulation of whole concept has been carried out as the non-premixed combustion process in the commercial final volume sw Pyrosim. Model of the combustion based on a stoichiometric defined mixture of gas and the tested layered samples showed good conformity with experimental results - i.e. thermal distribution inside and heat release rate that has gone through the sample.

  10. Feasibility of shutter-speed DCE-MRI for improved prostate cancer detection.

    PubMed

    Li, Xin; Priest, Ryan A; Woodward, William J; Tagge, Ian J; Siddiqui, Faisal; Huang, Wei; Rooney, William D; Beer, Tomasz M; Garzotto, Mark G; Springer, Charles S

    2013-01-01

    The feasibility of shutter-speed model dynamic-contrast-enhanced MRI pharmacokinetic analyses for prostate cancer detection was investigated in a prebiopsy patient cohort. Differences of results from the fast-exchange-regime-allowed (FXR-a) shutter-speed model version and the fast-exchange-limit-constrained (FXL-c) standard model are demonstrated. Although the spatial information is more limited, postdynamic-contrast-enhanced MRI biopsy specimens were also examined. The MRI results were correlated with the biopsy pathology findings. Of all the model parameters, region-of-interest-averaged K(trans) difference [ΔK(trans) ≡ K(trans)(FXR-a) - K(trans)(FXL-c)] or two-dimensional K(trans)(FXR-a) vs. k(ep)(FXR-a) values were found to provide the most useful biomarkers for malignant/benign prostate tissue discrimination (at 100% sensitivity for a population of 13, the specificity is 88%) and disease burden determination. (The best specificity for the fast-exchange-limit-constrained analysis is 63%, with the two-dimensional plot.) K(trans) and k(ep) are each measures of passive transcapillary contrast reagent transfer rate constants. Parameter value increases with shutter-speed model (relative to standard model) analysis are larger in malignant foci than in normal-appearing glandular tissue. Pathology analyses verify the shutter-speed model (FXR-a) promise for prostate cancer detection. Parametric mapping may further improve pharmacokinetic biomarker performance. Copyright © 2012 Wiley Periodicals, Inc.

  11. 16. Copy of a post card showing the Lavelle School, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. Copy of a post card showing the Lavelle School, c.1900; note that the building is one story in height and contains a one story addition in the rear. It also contains a projecting entrance tower and the windows have shutters. There are no windows or chimneys on the west wall and the front yard is defined by a wood picket fence on the west side and a metal picket fence on the north side. The identities of the children standing near the door are not known. (Copy of photo reproduced with permission from the Ashland Public Library and Mrs. Helen Edling, former Postmaster of Lavelle {she currently resides in Lavelle}; the original photograph is in Mrs. Edling's collection) - Lavelle School, Township Road 905, Main Street, Village of Lavelle, Lavelle, Schuylkill County, PA

  12. Solar concentrator protective system

    NASA Technical Reports Server (NTRS)

    Selcuk, M. K. (Inventor)

    1984-01-01

    A mechanism that blocks concentrated sunlight from reaching a receiver, in the event of a tracking failure or loss of coolant is described. Sunlight is normally concentrated by a dish reflector onto the opening of a receiver. A faceplate surrounds the opening, and coolant carrying tubes, line the receiver. If the concentrated sunlight wanders so it begins to fall on the faceplate, then the sunlight will melt a portion of a fuse wire portion will break. The wire is attached to a flange on a shutter frame, and breaking of the fuse wire allows the frame to fall. Normally, the shutter frame supports shutter elements that are held open by cam followers that bear against cams.

  13. Axial flow plasma shutter

    DOEpatents

    Krausse, George J.

    1988-01-01

    A shutter (36) is provided for controlling a beam, or current, of charged particles in a device such as a thyratron (10). The substrate (38) defines an aperture (60) with a gap (32) which is placeable within the current. Coils (48) are formed on the substrate (38) adjacent the aperture (60) to produce a magnetic field for trapping the charged particles in or about aperture (60). The proximity of the coils (48) to the aperture (60) enables an effective magnetic field to be generated by coils (48) having a low inductance suitable for high frequency control. The substantially monolithic structure including the substrate (38) and coils (48) enables the entire shutter assembly (36) to be effectively located with respect to the particle beam.

  14. Magnetic Characterization of Micro Shutters for James Web Space Telescope (JWST)

    NASA Technical Reports Server (NTRS)

    Wasilewski, P. (Technical Monitor); Kletetschka, Gunther

    2005-01-01

    Summary of Research that was part of the grant: NASA NAG5 - 13405: Magnetic Characterization of Micro Shutters for James Web Space Telescope (JWST) Period: May 1 2003-October 31 2005 The above funding resulted in following major achievements related to microshutter system for JWST. 1. The original rectangular pattern of magnetic material was changed into magnetic striped pattern to prevent unnecessary twisting during the actuation. The Original geometry favored magnetic remanence vector being oriented along the longer side of the shutter and thus resulting torque caused out of plane twist. Stripe pattern minimizes the out of plane motion and thus prolongs the life-time of microshutter device. 2. We built a new magnetic system (magnetic rotisserie) allowing an accelerated life test of microshutters at various temperatures. This system identified that shutter are capable to withstand as many as several millions of actuating cycles. Our system also identified fabrication related features, like bowing with temperature, collisions with the frame due to misalignment, delaminating of the light shields due to uncontrolled voltage release and poorly fabricated light shields.

  15. Cryogenic Characterization and Testing of Magnetically-Actuated Microshutter Arrays for the James Webb Space Telescope

    NASA Technical Reports Server (NTRS)

    King, T. T.; Kletetschka, G.; Jah, M. A.; Li, M. J.; Jhabvala, M. D.; Wang, L. L.; Beamesderfer, M. A.; Kutyrev, A. S.; Silverberg, R. F.; Rapchun, D.; hide

    2004-01-01

    Two-dimensional MEMS microshutter arrays (MSA) have been fabricated at the NASA Goddard Space Flight Center (GSFC) for the James Webb Space Telescope (JWST) to enable cryogenic (approximately 35 K) spectrographic astronomy measurements in the near-infrared region. Functioning as a focal plane object selection device, the MSA is a 2-D programmable aperture mask with fine resolution, high efficiency and high contrast. The MSA are close- packed silicon nitride shutters (cell size of 100 x 200 microns) patterned with a torsion flexure to allow opening to 90 degrees. A layer of magnetic material is deposited onto each shutter to permit magnetic actuation. Two electrodes are deposited, one onto each shutter and another onto the support structure side-wall, permitting electrostatic latching and 2-D addressing. New techniques were developed to test MSA under mission-similar conditions (8 K less than or equal to T less than 300K). The magnetic rotisserie has proven to be an excellent tool for rapid characterization of MSA. Tests conducted with the magnetic rotisserie method include accelerated cryogenic lifetesting of unpackaged 128 x 64 MSA and parallel measurement of the magneto-mechanical stiffness of shutters in pathfinder test samples containing multiple MSA designs. Lifetest results indicate a logarithmic failure rate out to approximately 10(exp 6) shutter actuations. These results have increased our understanding of failure mechanisms and provide a means to predict the overall reliability of MSA devices.

  16. Development and Operation of the Microshutter Array System

    NASA Technical Reports Server (NTRS)

    Jhabvala, M. D.; Franz, D.; King, T.; Kletetschka, G.; Kutyrev, A. S.; Li, M. J.

    2008-01-01

    The microshutter array (MSA) is a key component in the James Webb Space Telescope Near Infrared Spectrometer (NIRSpec) instrument. The James Webb Space Telescope is the next generation of a space-borne astronomy platform that is scheduled to be launched in 2013. However, in order to effectively operate the array and meet the severe operational requirements associated with a space flight mission has placed enormous constraints on the microshutter array subsystem. This paper will present an overview and description of the entire microshutter subsystem including the microshutter array, the hybridized array assembly, the integrated CMOS electronics, mechanical mounting module and the test methodology and performance of the fully assembled microshutter subsystem. The NIRSpec is a European Space Agency (ESA) instrument requiring four fully assembled microshutter arrays, or quads, which are independently addressed to allow for the imaging of selected celestial objects onto the two 4 mega pixel IR detectors. Each microshutter array must have no more than approx.8 shutters which are failed in the open mode (depending on how many are failed closed) out of the 62,415 (365x171) total number of shutters per array. The driving science requirement is to be able to select up to 100 objects at a time to be spectrally imaged at the focal plane. The spectrum is dispersed in the direction of the 171 shutters so if there is an unwanted open shutter in that row the light from an object passing through that failed open shutter will corrupt the spectrum from the intended object.

  17. DCS - A high flux beamline for time resolved dynamic compression science – Design highlights

    DOE PAGES

    Capatina, D.; D’Amico, K.; Nudell, J.; ...

    2016-07-27

    The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures.more » Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm 2. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm 2. Finally, a new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.« less

  18. DCS - A high flux beamline for time resolved dynamic compression science – Design highlights

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Capatina, D., E-mail: capatina@aps.anl.gov; D’Amico, K., E-mail: kdamico@aps.anl.gov; Nudell, J., E-mail: jnudell@aps.anl.gov

    2016-07-27

    The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures.more » Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm{sup 2}. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm{sup 2}. A new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.« less

  19. DCS - A High Flux Beamline for Time Resolved Dynamic Compression Science – Design Highlights

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Capatina, D.; D'Amico, Kevin L.; Nudell, J.

    2016-07-27

    The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures.more » Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm2. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm2. A new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.« less

  20. Real-time film recording from stroke-written CRT's

    NASA Technical Reports Server (NTRS)

    Hunt, R.; Grunwald, A. J.

    1980-01-01

    Real-time simulation studies often require motion-picture recording of events directly from stroke written cathode-ray tubes (CRT's). Difficulty presented is prevention of "flicker," which results from lack of synchronization between display sequence on CRT and shutter motion of camera. Programmable method has been devised for phasing display sequence to shutter motion, ensuring flicker-free recordings.

  1. Design and Manufacture of a Highly Reliable, Miniaturized and Low Mass Shutter Mechanism

    NASA Technical Reports Server (NTRS)

    Manhart, M.; Zeh, T.; Preibler, G.; Hurni, A.; Walter, I.; Helbert, J.; Hiesinger, H.

    2010-01-01

    This paper describes the development, manufacturing and testing of a lightweight shutter mechanism made of titanium for the MERTIS Instrument. MERTIS is a thermal infrared imaging spectrometer onboard ESA's future BepiColombo mission to Mercury. The mechanism is built as a parallelogram arrangement of flexible hinges, actuated by a voice coil. In a first test run, it was shown that the selected EDM processing led to the generation of titanium oxides and an oxygen-enriched surface layer on the substrate (so called alpha-case layer). In the revised version of the shutter, it was possible to manufacture the complex geometry by micro-milling and an adjacent pickling procedure. The adequacy of this approach was verified by lifetime and vibration testing.

  2. A high throughput liquid crystal light shutter for unpolarized light using polymer polarization gratings

    NASA Astrophysics Data System (ADS)

    Komanduri, Ravi K.; Lawler, Kris F.; Escuti, Michael J.

    2011-05-01

    We report on a broadband, diffractive, light shutter with the ability to modulate unpolarized light. This polarizer-free approach employs a conventional liquid crystal (LC) switch, combined with broadband Polarization Gratings (PGs) formed with polymer LC materials. The thin-film PGs act as diffractive polarizing beam-splitters, while the LC switch operates on both orthogonal polarization states simultaneously. As an initial experimental proof-of- concept for unpolarized light with +/-7° aperture, we utilize a commercial twisted-nematic LC switch and our own polymer PGs to achieve a peak transmittance of 80% and peak contrast ratio of 230:1. We characterize the optoelectronic performance, discuss the limitations, and evaluate its use in potential nonmechanical shutter applications (imaging and non-imaging).

  3. Wide dynamic logarithmic InGaAs sensor suitable for eye-safe active imaging

    NASA Astrophysics Data System (ADS)

    Ni, Yang; Bouvier, Christian; Arion, Bogdan; Noguier, Vincent

    2016-05-01

    In this paper, we present a simple method to analyze the injection efficiency of the photodiode interface circuit under fast shuttering conditions for active Imaging applications. This simple model has been inspired from the companion model for reactive elements largely used in CAD. In this paper, we demonstrate that traditional CTIA photodiode interface is not adequate for active imaging where fast and precise shuttering operation is necessary. Afterwards we present a direct amplification based photodiode interface which can provide an accurate and fast shuttering operation on photodiode. These considerations have been used in NIT's newly developed ROIC and corresponding SWIR sensors both in VGA 15um pitch (NSC1201) and also in QVGA 25um pitch (NSC1401).

  4. Compact microwave ion source for industrial applications.

    PubMed

    Cho, Yong-Sub; Kim, Dae-Il; Kim, Han-Sung; Seol, Kyung-Tae; Kwon, Hyeok-Jung; Hong, In-Seok

    2012-02-01

    A 2.45 GHz microwave ion source for ion implanters has many good properties for industrial application, such as easy maintenance and long lifetime, and it should be compact for budget and space. But, it has a dc current supply for the solenoid and a rf generator for plasma generation. Usually, they are located on high voltage platform because they are electrically connected with beam extraction power supply. Using permanent magnet solenoid and multi-layer dc break, high voltage deck and high voltage isolation transformer can be eliminated, and the dose rate on targets can be controlled by pulse duty control with semiconductor high voltage switch. Because the beam optics does not change, beam transfer components, such as focusing elements and beam shutter, can be eliminated. It has shown the good performances in budget and space for industrial applications of ion beams.

  5. 2D Electrostatic Actuation of Microshutter Arrays

    NASA Technical Reports Server (NTRS)

    Burns, Devin E.; Oh, Lance H.; Li, Mary J.; Kelly, Daniel P.; Kutyrev, Alexander S.; Moseley, Samuel H.

    2015-01-01

    Electrostatically actuated microshutter arrays consisting of rotational microshutters (shutters that rotate about a torsion bar) were designed and fabricated through the use of models and experiments. Design iterations focused on minimizing the torsional stiffness of the microshutters, while maintaining their structural integrity. Mechanical and electromechanical test systems were constructed to measure the static and dynamic behavior of the microshutters. The torsional stiffness was reduced by a factor of four over initial designs without sacrificing durability. Analysis of the resonant behavior of the microshutters demonstrates that the first resonant mode is a torsional mode occurring around 3000 Hz. At low vacuum pressures, this resonant mode can be used to significantly reduce the drive voltage necessary for actuation requiring as little as 25V. 2D electrostatic latching and addressing was demonstrated using both a resonant and pulsed addressing scheme.

  6. 2D Electrostatic Actuation of Microshutter Arrays

    NASA Technical Reports Server (NTRS)

    Burns, Devin E.; Oh, Lance H.; Li, Mary J.; Jones, Justin S.; Kelly, Daniel P.; Zheng, Yun; Kutyrev, Alexander S.; Moseley, Samuel H.

    2015-01-01

    An electrostatically actuated microshutter array consisting of rotational microshutters (shutters that rotate about a torsion bar) were designed and fabricated through the use of models and experiments. Design iterations focused on minimizing the torsional stiffness of the microshutters, while maintaining their structural integrity. Mechanical and electromechanical test systems were constructed to measure the static and dynamic behavior of the microshutters. The torsional stiffness was reduced by a factor of four over initial designs without sacrificing durability. Analysis of the resonant behavior of the microshutter arrays demonstrates that the first resonant mode is a torsional mode occurring around 3000 Hz. At low vacuum pressures, this resonant mode can be used to significantly reduce the drive voltage necessary for actuation requiring as little as 25V. 2D electrostatic latching and addressing was demonstrated using both a resonant and pulsed addressing scheme.

  7. Compact Laser System for Field Deployable Ultracold Atom Sensors

    NASA Astrophysics Data System (ADS)

    Pino, Juan; Luey, Ben; Anderson, Mike

    2013-05-01

    As ultracold atom sensors begin to see their way to the field, there is a growing need for small, accurate, and robust laser systems to cool and manipulate atoms for sensing applications such as magnetometers, gravimeters, atomic clocks and inertial sensing. In this poster we present a laser system for Rb, roughly the size of a paperback novel, capable of generating and controlling light sufficient for the most complicated of cold atom sensors. The system includes >100dB of non-mechanical, optical shuttering, the ability to create short, microsecond pulses, a Demux stage to port light onto different optical paths, and an atomically referenced, frequency agile laser source. We will present data to support the system, its Size Weight and Power (SWaP) requirements, as well as laser stability and performance. funded under DARPA

  8. High-speed quantitative phase imaging using time-stretch spectral shearing contrast (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Bosworth, Bryan; Foster, Mark A.

    2017-02-01

    Photonic time-stretch microscopy (TSM) provides an ideal platform for high-throughput imaging flow cytometry, affording extremely high shutter speeds and frame rates with high sensitivity. In order to resolve weakly scattering cells in biofluid and solve the issue of signal-to-noise in cell labeling specificity of biomarkers in imaging flow cytometry, several quantitative phase (QP) techniques have recently been adapted to TSM. However, these techniques have relied primarily on sensitive free-space optical configurations to generate full electric field measurements. The present work draws from the field of ultrashort pulse characterization to leverage the coherence of the ultrashort optical pulses integral to all TSM systems in order to do self-referenced single-shot quantitative phase imaging in a TSM system. Self-referencing is achieved via spectral shearing interferometry in an exceptionally stable and straightforward Sagnac loop incorporating an electro-optic phase modulator and polarization-maintaining fiber that produce sheared and unsheared copies of the pulse train with an inter-pulse delay determined by polarization mode dispersion. The spectral interferogram then yields a squared amplitude and a phase derivative image that can be integrated for conventional phase. We apply this spectral shearing contrast microscope to acquire QP images on a high-speed flow microscope at 90-MHz line rates with <400 pixels per line. We also consider the extension of this technique to compressed sensing (CS) acquisition by intensity modulating the interference spectra with pseudorandom binary waveforms to reconstruct the images from a highly sub-Nyquist number of random inner products, providing a path to even higher operating rates and reduced data storage requirements.

  9. Stoichiometry control of complex oxides by sequential pulsed-laser deposition from binary-oxide targets

    DOE PAGES

    Herklotz, A.; Dörr, Kathrin; Ward, T. Z.; ...

    2015-04-03

    In this paper, to have precise atomic layer control over interfaces, we examine the growth of complex oxides through the sequential deposition from binary targets by pulsed laser deposition. In situ reflection high-energy electron diffraction (RHEED) is used to control the growth and achieve films with excellent structural quality. The growth from binary oxide targets is fundamentally different from single target growth modes and shows more similarities to shuttered growth by molecular beam epitaxy. The RHEED intensity oscillations of non-stoichiometric growth are consistent with a model of island growth and accumulation of excess material on the surface that can bemore » utilized to determine the correct stoichiometry for growth. Correct monolayer doses can be determined through an envelope frequency in the RHEED intensity oscillations. In order to demonstrate the ability of this growth technique to create complex heterostructures, the artificial n = 2 and 3 Sr n +1Ti n O 3 n +1 Ruddlesden-Popper phases are grown with good long-range order. Finally, this method enables the precise unit-cell level control over the structure of perovskite-type oxides, and thus the growth of complex materials with improved structural quality and electronic functionality.« less

  10. An improved continuous compositional-spread technique based on pulsed-laser deposition and applicable to large substrate areas

    NASA Astrophysics Data System (ADS)

    Christen, H. M.; Rouleau, C. M.; Ohkubo, I.; Zhai, H. Y.; Lee, H. N.; Sathyamurthy, S.; Lowndes, D. H.

    2003-09-01

    A method for continuous compositional-spread (CCS) thin-film fabrication based on pulsed-laser deposition (PLD) is introduced. This approach is based on a translation of the substrate heater and the synchronized firing of the excimer laser, with the deposition occurring through a slit-shaped aperture. Alloying is achieved during film growth (possible at elevated temperature) by the repeated sequential deposition of submonolayer amounts. Our approach overcomes serious shortcomings in previous in situ implementation of CCS based on sputtering or PLD, in particular the variation of thickness across the compositional spread and the differing deposition energetics as a function of position. While moving-shutter techniques are appropriate for PLD approaches yielding complete spreads on small substrates (i.e., small as compared to distances over which the deposition parameters in PLD vary, typically ≈1 cm), our method can be used to fabricate samples that are large enough for individual compositions to be analyzed by conventional techniques, including temperature-dependent measurements of resistivity and dielectric and magnetic properties (i.e., superconducting quantum interference device magnetometry). Initial results are shown for spreads of (Sr1-xCax)RuO3.

  11. Stoichiometry control of complex oxides by sequential pulsed-laser deposition from binary-oxide targets

    DOE PAGES

    Herklotz, Andreas; Dorr, Kathrin; Ward, Thomas Zac; ...

    2015-04-03

    To have precise atomic layer control over interfaces, we examine the growth of complex oxides through the sequential deposition from binary targets by pulsed laser deposition. In situ reflection high-energy electron diffraction (RHEED) is used to control the growth and achieve films with excellent structural quality. The growth from binary oxide targets is fundamentally different from single target growth modes and shows more similarities to shuttered growth by molecular beam epitaxy. The RHEED intensity oscillations of non-stoichiometric growth are consistent with a model of island growth and accumulation of excess material on the surface that can be utilized to determinemore » the correct stoichiometry for growth. Correct monolayer doses can be determined through an envelope frequency in the RHEED intensity oscillations. In order to demonstrate the ability of this growth technique to create complex heterostructures, the artificial n = 2 and 3 Sr n+1Ti nO 3 n+1 Ruddlesden-Popper phases are grown with good long-range order. Furthermore, this method enables the precise unit-cell level control over the structure of perovskite-type oxides, and thus the growth of complex materials with improved structural quality and electronic functionality.« less

  12. CMO YAG laser damage test facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hue, J.; Dijon, J.; Lyan, P.

    1996-12-31

    The CMO YAG laser damage test facility, which is equipped with a 30Hz laser, is presented in this paper. The main points are described below: (1) The characteristics of the laser beam and the in situ damage detection technique (a scattered light measurement system) are perfectly suited to work up to the frequency of the laser. They are monitored in real time, and work at three wavelengths: 1064 nm, 532 nm, 355 nm. (2) With this same shutter, it is possible to automatically stop the laser on the pulse which induces the first damages. These automatic capabilities enable the samplesmore » to be tested quickly. (3) A Nomarski microscope supplied with a 16-bit CCD camera enables the test sites to be photographed before and after the laser interaction. Image processing enables the authors to extract the first damages. before and after the laser interaction. Image processing enables them to extract the first damages. (4) Six pulse widths are available (between 3ns and 13ns). Therefore, with all these characterization tools, many kinds of laser tests may be considered. These different features are illustrated by experimental results (1-on-1 test or R-on-1 test).« less

  13. Wobbly strings: calculating the capture rate of a webcam using the rolling shutter effect in a guitar

    NASA Astrophysics Data System (ADS)

    Cunnah, David

    2014-07-01

    In this paper I propose a method of calculating the time between line captures in a standard complementary metal-oxide-semiconductor (CMOS) webcam using the rolling shutter effect when filming a guitar. The exercise links the concepts of wavelength and frequency, while outlining the basic operation of a CMOS camera through vertical line capture.

  14. Wobbly Strings: Calculating the Capture Rate of a Webcam Using the Rolling Shutter Effect in a Guitar

    ERIC Educational Resources Information Center

    Cunnah, David

    2014-01-01

    In this paper I propose a method of calculating the time between line captures in a standard complementary metal-oxide-semiconductor (CMOS) webcam using the rolling shutter effect when filming a guitar. The exercise links the concepts of wavelength and frequency, while outlining the basic operation of a CMOS camera through vertical line capture.

  15. Towards Kilo-Hertz 6-DoF Visual Tracking Using an Egocentric Cluster of Rolling Shutter Cameras.

    PubMed

    Bapat, Akash; Dunn, Enrique; Frahm, Jan-Michael

    2016-11-01

    To maintain a reliable registration of the virtual world with the real world, augmented reality (AR) applications require highly accurate, low-latency tracking of the device. In this paper, we propose a novel method for performing this fast 6-DOF head pose tracking using a cluster of rolling shutter cameras. The key idea is that a rolling shutter camera works by capturing the rows of an image in rapid succession, essentially acting as a high-frequency 1D image sensor. By integrating multiple rolling shutter cameras on the AR device, our tracker is able to perform 6-DOF markerless tracking in a static indoor environment with minimal latency. Compared to state-of-the-art tracking systems, this tracking approach performs at significantly higher frequency, and it works in generalized environments. To demonstrate the feasibility of our system, we present thorough evaluations on synthetically generated data with tracking frequencies reaching 56.7 kHz. We further validate the method's accuracy on real-world images collected from a prototype of our tracking system against ground truth data using standard commodity GoPro cameras capturing at 120 Hz frame rate.

  16. Radiological implications of top-off operation at national synchrotron light source-II

    NASA Astrophysics Data System (ADS)

    Job, P. K.; Casey, W. R.

    2011-08-01

    High current and low emittance have been specified to achieve ultra high brightness in the third generation medium energy Synchrotron Radiation Sources. This leads to the electron beam lifetime limited by Touschek scattering, and after commissioning may settle in at as low as ∼3 h. It may well be less in the early days of operation. At the same time, the intensity stability specified by the user community for the synchrotron beam is 1% or better. Given the anticipated lifetime of the beam, incremental filling called top-off injection at intervals on the order of ∼1 min will be required to maintain this beam stability. It is judged to be impractical to make these incremental fills by closing the beam shutters at each injection. In addition, closing the front end beam shutters during each injection will adversely affect the stability of beamline optics due to thermal cycling. Hence the radiological consequences of injection with front end beam shutters open must be evaluated. This paper summarizes results of radiological analysis carried out for the proposed top-off injection at National Synchrotron Light Source-II (NSLS-II) with beam shutters open.

  17. A kind of fast shutter for Z pinch diagnosis device.

    PubMed

    Wang, Liangping; Zhang, Xinjun; Sun, Tieping; Mao, Wentin

    2016-09-01

    A kind of fast shutter for protecting the diagnosis devices in Z pinch experiments is introduced in this paper. The shutter is composed of a pulling rod, a magnetic core, and a solenoid. Different from the traditional coils which were used at the voltage of 220 V, the solenoid we used must endure the high voltage of 5-10 kV and the deformation which maybe caused by the 5-10 T intense magnetic field. A creative configuration for the solenoid is developed including the winding guide, insulating sleeve, and stainless-steel sleeve. The experimental results show that the configuration of the solenoid is effective. The velocity of the valve is nearly 19 m/s and the time jitter of the shutdown is within 75 μs.

  18. A kind of fast shutter for Z pinch diagnosis device

    NASA Astrophysics Data System (ADS)

    Wang, Liangping; Zhang, Xinjun; Sun, Tieping; Mao, Wentin

    2016-09-01

    A kind of fast shutter for protecting the diagnosis devices in Z pinch experiments is introduced in this paper. The shutter is composed of a pulling rod, a magnetic core, and a solenoid. Different from the traditional coils which were used at the voltage of 220 V, the solenoid we used must endure the high voltage of 5-10 kV and the deformation which maybe caused by the 5-10 T intense magnetic field. A creative configuration for the solenoid is developed including the winding guide, insulating sleeve, and stainless-steel sleeve. The experimental results show that the configuration of the solenoid is effective. The velocity of the valve is nearly 19 m/s and the time jitter of the shutdown is within 75 μs.

  19. Submillisecond fireball timing using de Bruijn timecodes

    NASA Astrophysics Data System (ADS)

    Howie, Robert M.; Paxman, Jonathan; Bland, Philip A.; Towner, Martin C.; Sansom, Eleanor K.; Devillepoix, Hadrien A. R.

    2017-08-01

    Long-exposure fireball photographs have been used to systematically record meteoroid trajectories, calculate heliocentric orbits, and determine meteorite fall positions since the mid-20th century. Periodic shuttering is used to determine meteoroid velocity, but up until this point, a separate method of precisely determining the arrival time of a meteoroid was required. We show it is possible to encode precise arrival times directly into the meteor image by driving the periodic shutter according to a particular pattern—a de Bruijn sequence—and eliminate the need for a separate subsystem to record absolute fireball timing. The Desert Fireball Network has implemented this approach using a microcontroller driven electro-optic shutter synchronized with GNSS UTC time to create small, simple, and cost-effective high-precision fireball observatories with submillisecond timing accuracy.

  20. Single-shot pressure-sensitive paint lifetime measurements on fast rotating blades using an optimized double-shutter technique

    NASA Astrophysics Data System (ADS)

    Weiss, Armin; Geisler, Reinhard; Schwermer, Till; Yorita, Daisuke; Henne, Ulrich; Klein, Christian; Raffel, Markus

    2017-09-01

    A pressure-sensitive paint (PSP) system is presented to measure global surface pressures on fast rotating blades. It is dedicated to solve the problem of blurred image data employing the single-shot lifetime method. The efficient blur reduction capability of an optimized double-shutter imaging technique is demonstrated omitting error-prone post-processing or laborious de-rotation setups. The system is applied on Mach-scaled DSA-9A helicopter blades in climb at various collective pitch settings and blade tip Mach and chord Reynolds numbers (M_{ {tip}} = 0.29-0.57; Re_{ {tip}} = 4.63-9.26 × 10^5). Temperature effects in the PSP are corrected by a theoretical approximation validated against measured temperatures using temperature-sensitive paint (TSP) on a separate blade. Ensemble-averaged PSP results are comparable to pressure-tap data on the same blade to within 250 Pa. Resulting pressure maps on the blade suction side reveal spatially high resolved flow features such as the leading edge suction peak, footprints of blade-tip vortices and evidence of laminar-turbulent boundary-layer (BL) transition. The findings are validated by a separately conducted BL transition measurement by means of TSP and numerical simulations using a 2D coupled Euler/boundary-layer code. Moreover, the principal ability of the single-shot technique to capture unsteady flow phenomena is stressed revealing three-dimensional pressure fluctuations at stall.

  1. Picosecond temporal contrast of Ti:Sapphire lasers (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Kalashnikov, Mikhail P.; Khodakovskiy, Nikita

    2017-05-01

    The temporal shape of recompressed Ti:sapphire CPA pulses typically contains relatively long pre- and post- pedestals appearing on a picosecond time scale. Despite playing a key role in laser-matter interactions, these artifacts - especially the shape of the leading front of the recompressed pulses - are poorly investigated and understood. The related publications consider picosecond pedestals appearing at both fronts of the main pulse to be related to scattering of the stretched pulse off diffraction gratings inside the stretcher or due to clipping of the pulse spectrum at dielectric coatings. In our experiments we analyzed different types of stretcher-compressor combinations used in Ti:Sapphire laser systems. These include a prism-based stretcher and a bulk compressor, transmission and reflection diffraction gratings - based combinations. We identified pedestals that are typical for the particular stretcher-compressor combination. Especially investigated are those which are coherent with the major recompressed pulse, since with self-phase modulation in power amplifiers they will grow nonlinearly and finally appear symmetric around the major pulse, generating the pre-pedestal from the post-pedestal. Thus, a previously unreported influence of the trailing pedestal has been identified. It is commonly known that recompressed pulses from Ti:sapphire chirped-pulse amplifier systems are accompanied by a slowly decaying ragged post-pedestal. The detailed investigation shows that it consists of numerous pulses with temporal separation in the picosecond range. These are coherent with the main pulse. Moreover, the temporal structure of the trailing pedestal is independent of the particular realization of the Ti:sapphire system and it is present in radiation of any Ti:Sapphire CPA system including Kerr- mode locked master oscillators. Our investigations show that the coherent ragged post-pedestal is the post-radiation of inverted Ti:sapphire medium resulting from phonon-photon interactions.

  2. Universal route to optimal few- to single-cycle pulse generation in hollow-core fiber compressors.

    PubMed

    Conejero Jarque, E; San Roman, J; Silva, F; Romero, R; Holgado, W; Gonzalez-Galicia, M A; Alonso, B; Sola, I J; Crespo, H

    2018-02-02

    Gas-filled hollow-core fiber (HCF) pulse post-compressors generating few- to single-cycle pulses are a key enabling tool for attosecond science and ultrafast spectroscopy. Achieving optimum performance in this regime can be extremely challenging due to the ultra-broad bandwidth of the pulses and the need of an adequate temporal diagnostic. These difficulties have hindered the full exploitation of HCF post-compressors, namely the generation of stable and high-quality near-Fourier-transform-limited pulses. Here we show that, independently of conditions such as the type of gas or the laser system used, there is a universal route to obtain the shortest stable output pulse down to the single-cycle regime. Numerical simulations and experimental measurements performed with the dispersion-scan technique reveal that, in quite general conditions, post-compressed pulses exhibit a residual third-order dispersion intrinsic to optimum nonlinear propagation within the fiber, in agreement with measurements independently performed in several laboratories around the world. The understanding of this effect and its adequate correction, e.g. using simple transparent optical media, enables achieving high-quality post-compressed pulses with only minor changes in existing setups. These optimized sources have impact in many fields of science and technology and should enable new and exciting applications in the few- to single-cycle pulse regime.

  3. Surveillance of Space Concept Demonstrator. Presentation of One Sensor: CASTOR-V

    DTIC Science & Technology

    2007-04-01

    30ºC to minimize the significant dark count (noise) gradient, and that the highest binning mode that will not incur resolution loss must be selected...38 5.1.4 Dome issue 3: Shutter malfunctioning...Dome motor and its controller used to rotate the observatory dome of CASTOR-V10 Figure 8. Dome shutter and wind screen motors and the controller

  4. Low-Light-Shift Cesium Fountain without Mechanical Shutters

    NASA Technical Reports Server (NTRS)

    Enzer, Daphna

    2008-01-01

    A new technique for reducing errors in a laser-cooled cesium fountain frequency standard provides for strong suppression of the light shift without need for mechanical shutters. Because mechanical shutters are typically susceptible to failure after operating times of the order of months, the elimination of mechanical shutters could contribute significantly to the reliability of frequency standards that are required to function continuously for longer time intervals. With respect to the operation of an atomic-fountain frequency standard, the term "light shift" denotes an undesired relative shift in the two energy levels of the atoms (in this case, cesium atoms) in the atomic fountain during interrogation by microwaves. The shift in energy levels translates to a frequency shift that reduces the precision and possibly accuracy of the frequency standard. For reasons too complex to describe within the space available for this article, the light shift is caused by any laser light that reaches the atoms during the microwave- interrogation period, but is strongest for near-resonance light. In the absence of any mitigating design feature, the light shift, expressed as a fraction of the standard fs frequency, could be as large as approx. 2 x 10(exp -11), the largest error in the standard. In a typical prior design, to suppress light shift, the intensity of laser light is reduced during the interrogation period by using a single-pass acoustooptic modulator to deflect the majority of light away from the main optical path. Mechanical shutters are used to block the remaining undeflected light to ensure complete attenuation. Without shutters, this remaining undeflected light could cause a light shift of as much as .10.15, which is unacceptably large in some applications. The new technique implemented here involves additionally shifting the laser wavelength off resonance by a relatively large amount (typically of the order of nanometers) during microwave interrogation. In this design, when microwave interrogation is not underway, the atoms are illuminated by a slave laser locked to the lasing frequency of a lower power master laser.

  5. Low energy high angular resolution neutral atom detection by means of micro-shuttering techniques: the BepiColombo SERENA/ELENA unit development

    NASA Astrophysics Data System (ADS)

    Orsini, S.; di Lellis, A. M.; Milillo, A.; Selci, S.; Leoni, R.; Dandouras, I.

    2009-04-01

    ELENA (Emitted Low-Energy Neutral Atoms) is a Time-of-Flight (ToF) system, based on oscillating shutter (operated at frequencies up to a 100 kHz) and mechanical gratings devoted to sputtering emission from planetary surfaces, from E ~20 eV up to E ~5 keV. This new kind of low energetic neutral atoms instrument is one of the four units of the SERENA experiment for the ESA cornerstone BepiColombo mission to Mercury. The low energetic neutral particles that are likely to be detected by ELENA come primarily from ion-sputtering process, and secondarily from back-scattering and from charge exchange. ELENA will resolve intensity, velocity and direction of the incoming particle flux: the entrance of the start section (an aperture of about 1 cm2consisting of two self-standing silicon nitride (Si3N4) membranes, patterned with arrays of long and narrow openings) allows the impinging neutral particles to enter through the shuttering system with a definite timing. Particles are then flown in a ToF chamber, and finally detected by a 1-dimensional array composed by MCPs and a discrete anodes set corresponding to a Field of View (FOV) of 4.5"x76", allowing the reconstruction of both velocity and direction of the incoming events. This poster will present the new results of the ELENA development in the frame of the scientific items, instrument simulation, laboratory activity and testing. In particular, the ELENA input section and shuttering system will be reported (new deflector system, shuttering functionality test, membranes VUV optical proprieties and particle beam interactions).

  6. Introduction of a mutation in the shutter region of antithrombin (Phe77 --> Leu) increases affinity for heparin and decreases thermal stability.

    PubMed

    Quinsey, Noelene S; Fitton, Hazel L; Coughlin, Paul; Whisstock, James C; Dafforn, Timothy R; Carrell, Robin W; Bottomley, Stephen P; Pike, Robert N

    2003-09-02

    The shutter region of serpins consists of a number of highly conserved residues that are critical for both stability and function. Several variants of antithrombin with substitutions in this region are unstable and predispose the carrier to thrombosis. Although most mutations in the shutter region investigated to date are deleterious with respect to serpin stability and function, the substitution of Phe51 by Leu in alpha(1)-antitrypsin results in enhanced stability. Here, we have investigated the effects of introducing an analogous mutation into antithrombin (Phe 77 to Leu). The mutation did not affect the kinetics of interaction with proteases. Strikingly, however, the thermostability of the protein was markedly decreased, with the serpin displaying a 13 degrees C decrease in melting temperature as compared to wild-type recombinant antithrombin. Further studies revealed that in contrast to wild-type antithrombin, the mutant adopted the latent (inactive) conformation upon mild heating. Previous studies on shutter region mutations that destabilize antithrombin revealed that such variants possess enhanced affinity for both heparin pentasaccharide and full-length heparin. The N135A/F77L mutant had unchanged affinity for heparin pentasaccharide, but the affinity for full-length heparin was increased. We suggest that the Phe77Leu mutation causes conformational changes around the top of the D-helix in antithrombin, in particular, to the arginine 132 and 133 residues that may mediate additional antithrombin/heparin interactions. This paper also demonstrates that there are major differences between the shutter regions of antithrombin and alpha(1)-antitrypsin since a stabilizing mutation in antitrypsin has the converse effect in antithrombin.

  7. Microsecond-range optical shutter for unpolarized light with chiral nematic liquid crystal

    NASA Astrophysics Data System (ADS)

    Mohammadimasoudi, Mohammad; Shin, Jungsoon; Lee, Keechang; Neyts, Kristiaan; Beeckman, Jeroen

    2015-04-01

    A fast electro-optic shutter is fabricated and demonstrated. The device works independently of the polarization state of the incoming light beam. Modulation between 3% transmission and 60% transmission is obtained within a wavelength range of 50 nm with a response time of 20 μs. The device consists of two partly polymerized chiral nematic liquid crystal layers separated by a half wave plate. The transmission modulation is due to a 50 nm wavelength shift of the photonic band gap of the chiral liquid crystal realized by applying an electric field over a mixture of photo-polymerized LC and non-reactive nematic LC containing a chiral dopant. The shutter features high reflectivity in the photonic band gap. We investigate the influence of the amplitude of the applied voltage on the width and the depth of the reflection band.

  8. Setting up a mobile Lidar (DIAL) system for detecting chemical warfare agents

    NASA Astrophysics Data System (ADS)

    Kavosh Tehrani, M.; Mohammad, M. Malek; Jaafari, E.; Mobashery, A.

    2015-03-01

    The mobile light detection and ranging DIAL system of Malek Ashtar University of Technology has been developed for the detection of chemical warfare agents whose absorption wavelengths are in the range of 9.2-10.8 μm tunable CO2 lasers of the system. In this paper, this system is first described and then ammonia detection is analyzed experimentally. Also, experimental results of detecting a sarin agent simulant, dimethyl-methyl phosphonate (DMMP), are presented. The power levels received from different ranges to detect specific concentrations of NH3 and DMMP have been measured and debated. The primary test results with a 150 ns clipped pulse width by passive pinhole plasma shutter indicate that the system is capable of monitoring several species of pollutants in the range of about 1 km, with a 20 m spatial and 2 min temporal resolution.

  9. Characterization of CNRS Fizeau wedge laser tuner

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    A fringe detection and measurement system was constructed for use with the CNRS Fizeau wedge laser tuner, consisting of three circuit boards. The first board is a standard Reticon RC-100 B motherboard which is used to provide the timing, video processing, and housekeeping functions required by the Reticon RL-512 G photodiode array used in the system. The sampled and held video signal from the motherboard is processed by a second, custom-fabricated circuit board which contains a high-speed fringe detection and locating circuit. This board includes a dc level-discriminator-type fringe detector, a counter circuit to determine fringe center, a pulsed lasermore » triggering circuit, and a control circuit to operate the shutter for the He-Ne reference laser beam. The fringe center information is supplied to the third board, a commercial single board computer, which governs the data-collection process and interprets the results.« less

  10. Characterization of CNRS Fizeau wedge laser tuner

    NASA Technical Reports Server (NTRS)

    1984-01-01

    A fringe detection and measurement system was constructed for use with the CNRS Fizeau wedge laser tuner, consisting of three circuit boards. The first board is a standard Reticon RC-100 B motherboard which is used to provide the timing, video processing, and housekeeping functions required by the Reticon RL-512 G photodiode array used in the system. The sampled and held video signal from the motherboard is processed by a second, custom fabricated circuit board which contains a high speed fringe detection and locating circuit. This board includes a dc level discriminator type fringe detector, a counter circuit to determine fringe center, a pulsed laser triggering circuit, and a control circuit to operate the shutter for the He-Ne reference laser beam. The fringe center information is supplied to the third board, a commercial single board computer, which governs the data collection process and interprets the results.

  11. Measurement of Drop Size Distribution and Liquid Water Content in Natural Clouds - Installation and Calibration of Infrared Spectrometer

    DTIC Science & Technology

    1952-07-01

    The chopper has been removed from its case and the motor , shutter, and breaker assembly have been mounted in such a position that the two beams Will...yaao7U v»i uxi Out? VUIUUI ViOCX OUi * •** Mazda lamp is substituted for the giobar» Turning the shutter by hand cam No« 1 is phased so

  12. Nonlocal Position Changes of a Photon Revealed by Quantum Routers.

    PubMed

    Elitzur, Avshalom C; Cohen, Eliahu; Okamoto, Ryo; Takeuchi, Shigeki

    2018-05-16

    Since its publication, Aharonov and Vaidman's three-box paradox has undergone three major advances: i). A non-counterfactual scheme by the same authors in 2003 with strong rather than weak measurements for verifying the particle's subtle presence in two boxes. ii) A realization of the latter by Okamoto and Takeuchi in 2016. iii) A dynamic version by Aharonov et al. in 2017, with disappearance and reappearance of the particle. We now combine these advances together. Using photonic quantum routers the particle acts like a quantum "shutter." It is initially split between Boxes A, B and C, the latter located far away from the former two. The shutter particle's whereabouts can then be followed by a probe photon, split in both space and time and reflected by the shutter in its varying locations. Measuring the former is expected to reveal the following time-evolution: The shutter particle was, with certainty, in boxes A+C at t 1 , then only in C at t 2 , and finally in B+C at t 3 . Another branch of the split probe photon can show that boxes A+B were empty at t 2 . A Bell-like theorem applied to this experiment challenges any alternative interpretation that avoids disappearance-reappearance in favor of local hidden variables.

  13. Unique dome design for the SOAR telescope project

    NASA Astrophysics Data System (ADS)

    Teran, Jose U.; Porter, David S.; Hileman, Edward A.; Neff, Daniel H.

    2000-08-01

    The SOAR telescope dome is a 20 meter diameter 5/8 spherical structure built on a rotating steel frame with an over the top nesting shutter and covered with a fiberglass panel system. The insulated fiberglass panel system can be self- supporting and is typically used for radomes on ground based tracking systems. The enclosed observing area is ventilated using a down draft ventilation system. The rotating steel frame is comprised of a ring beam and dual arch girders to provide support to the panel system sections and guide the shutter. The dual door shutter incorporates a unique differential drive system that reduces the complexity of the control system. The dome, shutter and windscreen `track' the telescope for maximum wind protection. The dome rotates on sixteen fixed compliant bogie assemblies. The dome is designed for assembly in sections off the facility and lifted into place for minimal impact on assembly of other telescope systems. The expected cost of the complete dome; including structure, drives, and controls is under 1.7 million. The details covered in this paper are the initial trade-offs and rationale required by SOAR to define the dome, the detailed design performed by M3 Engineering and Technology, and the choices made during the design.

  14. Light in flight photography and applications (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Faccio, Daniele

    2017-02-01

    The first successful attempts (Abramson) at capturing light in flight relied on the holographic interference between the ``object'' beam scattered from a screen and a short reference pulse propagating at an angle, acting as an ultrafast shutter cite{egg}. This interference pattern was recorded on a photographic plate or film and allowed the visualisation of light as it propagated through complex environments with unprecedented temporal and spatial resolution. More recently, advances in ultrafast camera technology and in particular the use of picosecond resolution streak cameras allowed the direct digital recording of a light pulse propagating through a plastic bottle (Rasker at el.). This represented a remarkable step forward as it provided the first ever video recording (in the traditional sense with which one intends a video, i.e. something that can be played back directly on a screen and saved in digital format) of a pulse of light in flight. We will discuss a different technology that is based on an imaging camera with a pixel array in which each individual pixel is a single photon avalanche diode (SPAD). SPADs offer both sensitivity to single photons and picosecond temporal resolution of the photon arrival time (with respect to a trigger event). When adding imaging capability, SPAD arrays can deliver videos of light pulse propagating in free space, without the need for a scattering medium or diffuser as in all previous work (Gariepy et al). This capability can then be harnessed for a variety of applications. We will discuss the details of SPAD camera detection of moving objects (e.g. human beings) that are hidden from view and then conclude with a discussion of future perspectives in the field of bio-imaging.

  15. Breaking Waves and Microwave Polarimetric Emissivities: Final Report

    DTIC Science & Technology

    2005-04-11

    in designing and evaluating the errors in retrieval algorithms for CMIS. REFERENCES Asher, W.E., T.M. Litchendorf, and K. Phadnis , The effect of...IEEE Trans. Geosci. Rem. Sensing, 33, 85-92, 1995. PEER-REVIEWED PUBLICATIONS Asher, W.E., T.M. Litchendorf and K. Phadnis . "The Effect of Shutter...Alaska, September, 2004. Asher, W.E., T.M. Litchendorf and K. Phadnis , 2004. "The Effect of Shutter Speed on Measuring Size-Segregated Bubble

  16. [Three-dimensional display simulation of lung surgery using "active shutter glasses"].

    PubMed

    Onuki, Takamasa; Kanzaki, Masato; Sakamoto, Kei; Kikkawa, Takuma; Isaka, Tamami; Shimizu, Toshihide; Oyama, Kunihiro; Murasugi, Masahide

    2011-08-01

    We have reported preoperative 3-dimensional (3D) simulation of thoracoscopic lung surgery using self-made software and internet shareware of 3D-modeler. Using "active shutter glasses", we have tried the "3D display simulation" of lung surgery. 3D display was more effective to grasp clear 3D interrelation between the bronchii and pulmonary vascular system than those in images of currently in use with the same information volume.

  17. Cryogenic Photogrammetry and Radiometry for the James Webb Space Telescope Microshutters

    NASA Technical Reports Server (NTRS)

    Chambers, Victor J.; Morey, Peter A.; Zukowski, Barbara J.; Kutyrev, Alexander S.; Collins, Nicholas R.

    2012-01-01

    The James Webb Space Telescope (JWST) relies on several innovations to complete its five year mission. One vital technology is microshutters, the programmable field selectors that enable the Near Infrared Spectrometer (NIRSpec) to perform multi-object spectroscopy. Mission success depends on acquiring spectra from large numbers of galaxies by positioning shutter slits over faint targets. Precise selection of faint targets requires field selectors that are both high in contrast and stable in position. We have developed test facilities to evaluate microshutter contrast and alignment stability at their 35K operating temperature. These facilities used a novel application of image registration algorithms to obtain non-contact, sub-micron measurements in cryogenic conditions. The cryogenic motion of the shutters was successfully characterized. Optical results also demonstrated that shutter contrast far exceeds the NIRSpec requirements. Our test program has concluded with the delivery of a flight-qualified field selection subsystem to the NIRSpec bench.

  18. Light shift measurements in a Cesium Fountain without the use of mechanical shutters

    NASA Technical Reports Server (NTRS)

    Tjoelker, Robert L.; Enzer, D. G.; Klipstein, W. M.

    2005-01-01

    We present measurements confirming operation of a cesium fountain frequency standard with light shift below 10^-15 (and with evidence suggesting it is several orders of magnitude below this level) but without the use of mechanical shutters. Suppression of the light shift is realized using a master-slave laser configuration by reducing the overall optical power delivered to the physics package as well as spoiling the injection of the slave, causing it to lase far off resonance (1-2 nm) as proposed by the authors several years ago [l]. In the absence of any mitigation, this (AC Stark) shift, due to near-resonant laser light reaching the atoms during their microwave interrogation period, is the largest shift in such frequency standards (2x10^-11 for Our fountain). Mechanical shutters provided adequate light attenuation but have been prone to failure.

  19. Decoding mobile-phone image sensor rolling shutter effect for visible light communications

    NASA Astrophysics Data System (ADS)

    Liu, Yang

    2016-01-01

    Optical wireless communication (OWC) using visible lights, also known as visible light communication (VLC), has attracted significant attention recently. As the traditional OWC and VLC receivers (Rxs) are based on PIN photo-diode or avalanche photo-diode, deploying the complementary metal-oxide-semiconductor (CMOS) image sensor as the VLC Rx is attractive since nowadays nearly every person has a smart phone with embedded CMOS image sensor. However, deploying the CMOS image sensor as the VLC Rx is challenging. In this work, we propose and demonstrate two simple contrast ratio (CR) enhancement schemes to improve the contrast of the rolling shutter pattern. Then we describe their processing algorithms one by one. The experimental results show that both the proposed CR enhancement schemes can significantly mitigate the high-intensity fluctuations of the rolling shutter pattern and improve the bit-error-rate performance.

  20. Microsecond-range optical shutter for unpolarized light with chiral nematic liquid crystal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohammadimasoudi, Mohammad, E-mail: Mohammad.Mohammadimasoudi@elis.ugent.be; Neyts, Kristiaan; Beeckman, Jeroen

    2015-04-15

    A fast electro-optic shutter is fabricated and demonstrated. The device works independently of the polarization state of the incoming light beam. Modulation between 3% transmission and 60% transmission is obtained within a wavelength range of 50 nm with a response time of 20 μs. The device consists of two partly polymerized chiral nematic liquid crystal layers separated by a half wave plate. The transmission modulation is due to a 50 nm wavelength shift of the photonic band gap of the chiral liquid crystal realized by applying an electric field over a mixture of photo-polymerized LC and non-reactive nematic LC containingmore » a chiral dopant. The shutter features high reflectivity in the photonic band gap. We investigate the influence of the amplitude of the applied voltage on the width and the depth of the reflection band.« less

  1. Stroboscopic Image Modulation to Reduce the Visual Blur of an Object Being Viewed by an Observer Experiencing Vibration

    NASA Technical Reports Server (NTRS)

    Kaiser, Mary K. (Inventor); Adelstein, Bernard D. (Inventor); Anderson, Mark R. (Inventor); Beutter, Brent R. (Inventor); Ahumada, Albert J., Jr. (Inventor); McCann, Robert S. (Inventor)

    2014-01-01

    A method and apparatus for reducing the visual blur of an object being viewed by an observer experiencing vibration. In various embodiments of the present invention, the visual blur is reduced through stroboscopic image modulation (SIM). A SIM device is operated in an alternating "on/off" temporal pattern according to a SIM drive signal (SDS) derived from the vibration being experienced by the observer. A SIM device (controlled by a SIM control system) operates according to the SDS serves to reduce visual blur by "freezing" (or reducing an image's motion to a slow drift) the visual image of the viewed object. In various embodiments, the SIM device is selected from the group consisting of illuminator(s), shutter(s), display control system(s), and combinations of the foregoing (including the use of multiple illuminators, shutters, and display control systems).

  2. NASA Engineers Conduct Low Light Test on New Technology for NASA Webb Telescope

    NASA Image and Video Library

    2014-09-02

    NASA engineers inspect a new piece of technology developed for the James Webb Space Telescope, the micro shutter array, with a low light test at NASA's Goddard Space Flight Center in Greenbelt, Maryland. Developed at Goddard to allow Webb's Near Infrared Spectrograph to obtain spectra of more than 100 objects in the universe simultaneously, the micro shutter array uses thousands of tiny shutters to capture spectra from selected objects of interest in space and block out light from all other sources. Credit: NASA/Goddard/Chris Gunn NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  3. Transmembrane molecular transport during versus after extremely large, nanosecond electric pulses.

    PubMed

    Smith, Kyle C; Weaver, James C

    2011-08-19

    Recently there has been intense and growing interest in the non-thermal biological effects of nanosecond electric pulses, particularly apoptosis induction. These effects have been hypothesized to result from the widespread creation of small, lipidic pores in the plasma and organelle membranes of cells (supra-electroporation) and, more specifically, ionic and molecular transport through these pores. Here we show that transport occurs overwhelmingly after pulsing. First, we show that the electrical drift distance for typical charged solutes during nanosecond pulses (up to 100 ns), even those with very large magnitudes (up to 10 MV/m), ranges from only a fraction of the membrane thickness (5 nm) to several membrane thicknesses. This is much smaller than the diameter of a typical cell (∼16 μm), which implies that molecular drift transport during nanosecond pulses is necessarily minimal. This implication is not dependent on assumptions about pore density or the molecular flux through pores. Second, we show that molecular transport resulting from post-pulse diffusion through minimum-size pores is orders of magnitude larger than electrical drift-driven transport during nanosecond pulses. While field-assisted charge entry and the magnitude of flux favor transport during nanosecond pulses, these effects are too small to overcome the orders of magnitude more time available for post-pulse transport. Therefore, the basic conclusion that essentially all transmembrane molecular transport occurs post-pulse holds across the plausible range of relevant parameters. Our analysis shows that a primary direct consequence of nanosecond electric pulses is the creation (or maintenance) of large populations of small pores in cell membranes that govern post-pulse transmembrane transport of small ions and molecules. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Transmembrane molecular transport during versus after extremely large, nanosecond electric pulses

    PubMed Central

    Smith, Kyle C.; Weaver, James C.

    2012-01-01

    Recently there has been intense and growing interest in the non-thermal biological effects of nanosecond electric pulses, particularly apoptosis induction. These effects have been hypothesized to result from the widespread creation of small, lipidic pores in the plasma and organelle membranes of cells (supra-electroporation) and, more specifically, ionic and molecular transport through these pores. Here we show that transport occurs overwhelmingly after pulsing. First, we show that the electrical drift distance for typical charged solutes during nanosecond pulses (up to 100 ns), even those with very large magnitudes (up to 10 MV/m), ranges from only a fraction of the membrane thickness (5 nm) to several membrane thicknesses. This is much smaller than the diameter of a typical cell (~16 μm), which implies that molecular drift transport during nanosecond pulses is necessarily minimal. This implication is not dependent on assumptions about pore density or the molecular flux through pores. Second, we show that molecular transport resulting from post-pulse diffusion through minimum-size pores is orders of magnitude larger than electrical drift-driven transport during nanosecond pulses. While field-assisted charge entry and the magnitude of flux favor transport during nanosecond pulses, these effects are too small to overcome the orders of magnitude more time available for post-pulse transport. Therefore, the basic conclusion that essentially all transmembrane molecular transport occurs post-pulse holds across the plausible range of relevant parameters. Our analysis shows that a primary direct consequence of nanosecond electric pulses is the creation (or maintenance) of large populations of small pores in cell membranes that govern post-pulse transmembrane transport of small ions and molecules. PMID:21756883

  5. The Role of Near-Fault Relief in Creating and Maintaining Strike-Slip Landscape Features

    NASA Astrophysics Data System (ADS)

    Harbert, S.; Duvall, A. R.; Tucker, G. E.

    2016-12-01

    Geomorphic landforms, such as shutter ridges, offset river terraces, and deflected stream channels, are often used to assess the activity and slip rates of strike-slip faults. However, in some systems, such as parts of the Marlborough Fault System (South Island, NZ), an active strike-slip fault does not leave a strong landscape signature. Here we explore the factors that dampen or enhance the landscape signature of strike-slip faulting using the Channel-Hillslope Integrated Landscape Development model (CHILD). We focus on variables affecting the length of channel offsets, which enhance the signature of strike-slip motion, and the frequency of stream captures, which eliminate offsets and reduce this signature. We model a strike-slip fault that passes through a mountain ridge, offsetting streams that drain across this fault. We use this setup to test the response of channel offset length and capture frequency to fault characteristics, such as slip rate and ratio of lateral to vertical motion, and to landscape characteristics, such as relief contrasts controlled by erodibility. Our experiments show that relief downhill of the fault, whether generated by differential uplift across the fault or by an erodibility contrast, has the strongest effect on offset length and capture frequency. This relief creates shutter ridges, which block and divert streams while being advected along a fault. Shutter ridges and the streams they divert have long been recognized as markers of strike-slip motion. Our results show specifically that the height of shutter ridges is most responsible for the degree to which they create long channel offsets by preventing stream captures. We compare these results to landscape metrics in the Marlborough Fault System, where shutter ridges are common and often lithologically controlled. We compare shutter ridge length and height to channel offset length in order to assess the influence of relief on offset channel features in a real landscape. Based on our model and field results, we conclude that vertical relief is important for generating and preserving offset features that are viewed as characteristic of a strike-slip fault. Therefore, the geomorphic expression of a fault may be dependent on characteristics of the surrounding landscape rather than primarily a function of the nature of slip on the fault.

  6. Thin-film optical shutter. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matlow, S.L.

    1981-02-01

    A specific embodiment of macroconjugated macromolecules, the poly (p-phenylene)'s, has been chosen as the one most likely to meet all of the requirements of the Thin Film Optical Shutter project (TFOS). The reason for this choice is included. In order to be able to make meaningful calculations of the thermodynamic and optical properties of the poly (p-phenylene)'s a new quantum mechanical method was developed - Equilibrium Bond Length (EBL) Theory. Some results of EBL Theory are included.

  7. Planning JWST NIRSpec MSA spectroscopy using NIRCam pre-images

    NASA Astrophysics Data System (ADS)

    Beck, Tracy L.; Ubeda, Leonardo; Kassin, Susan A.; Gilbert, Karoline; Karakla, Diane M.; Reid, I. N.; Blair, William P.; Keyes, Charles D.; Soderblom, D. R.; Peña-Guerrero, Maria A.

    2016-07-01

    The Near-Infrared Spectrograph (NIRSpec) is the work-horse spectrograph at 1-5microns for the James Webb Space Telescope (JWST). A showcase observing mode of NIRSpec is the multi-object spectroscopy with the Micro-Shutter Arrays (MSAs), which consist of a quarter million tiny configurable shutters that are 0. ''20×0. ''46 in size. The NIRSpec MSA shutters can be opened in adjacent rows to create flexible and positionable spectroscopy slits on prime science targets of interest. Because of the very small shutter width, the NIRSpec MSA spectral data quality will benefit significantly from accurate astrometric knowledge of the positions of planned science sources. Images acquired with the Hubble Space Telescope (HST) have the optimal relative astrometric accuracy for planning NIRSpec observations of 5-10 milli-arcseconds (mas). However, some science fields of interest might have no HST images, galactic fields can have moderate proper motions at the 5mas level or greater, and extragalactic images with HST may have inadequate source information at NIRSpec wavelengths beyond 2 microns. Thus, optimal NIRSpec spectroscopy planning may require pre-imaging observations with the Near-Infrared Camera (NIRCam) on JWST to accurately establish source positions for alignment with the NIRSpec MSAs. We describe operational philosophies and programmatic considerations for acquiring JWST NIRCam pre-image observations for NIRSpec MSA spectroscopic planning within the same JWST observing Cycle.

  8. Analysis of the diffraction effects for a multi-view autostereoscopic three-dimensional display system based on shutter parallax barriers with full resolution

    NASA Astrophysics Data System (ADS)

    Meng, Yang; Yu, Zhongyuan; Jia, Fangda; Zhang, Chunyu; Wang, Ye; Liu, Yumin; Ye, Han; Chen, Laurence Lujun

    2017-10-01

    A multi-view autostereoscopic three-dimensional (3D) system is built by using a 2D display screen and a customized parallax-barrier shutter (PBS) screen. The shutter screen is controlled dynamically by address driving matrix circuit and it is placed in front of the display screen at a certain location. The system could achieve densest viewpoints due to its specially optical and geometric design which is based on concept of "eye space". The resolution of 3D imaging is not reduced compared to 2D mode by using limited time division multiplexing technology. The diffraction effects may play an important role in 3D display imaging quality, especially when applied to small screen, such as iPhone screen etc. For small screen, diffraction effects may contribute crosstalk between binocular views, image brightness uniformity etc. Therefore, diffraction effects are analyzed and considered in a one-dimensional shutter screen model of the 3D display, in which the numerical simulation of light from display pixels on display screen through parallax barrier slits to each viewing zone in eye space, is performed. The simulation results provide guidance for criteria screen size over which the impact of diffraction effects are ignorable, and below which diffraction effects must be taken into account. Finally, the simulation results are compared to the corresponding experimental measurements and observation with discussion.

  9. Post-filamentation high-intensive light channels formation upon ultrashort laser pulses self-focusing in air

    NASA Astrophysics Data System (ADS)

    Geints, Yu. E.; Ionin, A. A.; Mokrousova, D. V.; Seleznev, L. V.; Sinitsyn, D. V.; Sunchugasheva, E. S.; Zemlyanov, A. A.

    2017-01-01

    Experimental and theoretical study of the post-filamentation stage of focused high-power Ti:Sa laser pulses in air is presented. Angular divergence of the laser beam, as well as angular and spatial characteristics of specific spatially localized light structures, the post-filament channels (PFCs), under different initial focusing conditions and laser beam energy are investigated. We show that PFC angular divergence is always less than that of the whole laser beam and tends to decrease with laser pulse energy increase and beam focal length elongation.

  10. Efficient demodulation scheme for rolling-shutter-patterning of CMOS image sensor based visible light communications.

    PubMed

    Chen, Chia-Wei; Chow, Chi-Wai; Liu, Yang; Yeh, Chien-Hung

    2017-10-02

    Recently even the low-end mobile-phones are equipped with a high-resolution complementary-metal-oxide-semiconductor (CMOS) image sensor. This motivates using a CMOS image sensor for visible light communication (VLC). Here we propose and demonstrate an efficient demodulation scheme to synchronize and demodulate the rolling shutter pattern in image sensor based VLC. The implementation algorithm is discussed. The bit-error-rate (BER) performance and processing latency are evaluated and compared with other thresholding schemes.

  11. Flash protection controller

    DOEpatents

    Galbraith, L.K.

    1979-12-07

    A controller provides a high voltage to maintain an electro-optic shutter in a transparent condition until a flash of light which would be harmful to personnel is sensed by a phototransistor. The controller then shorts the shutter to ground to minimize light transmission to the user and maintains light transmission at the pre-flash level for a predetermined time to allow the flash to subside. A log converter and differential trigger circuit keep the controller from being triggered by other light flashes which are not dangerous.

  12. Flash protection controller

    DOEpatents

    Galbraith, Lee K.

    1981-01-01

    A controller provides a high voltage to maintain an electro-optic shutter in a transparent condition until a flash of light which would be harmful to personnel is sensed by a phototransistor. The controller then shorts the shutter to ground to minimize light transmission to the user and maintains light transmission at the pre-flash level for a predetermined time to allow the flash to subside. A log converter and differential trigger circuit keep the controller from being triggered by other light flashes which are not dangerous.

  13. Process for Making a Semiconductor Device with Barrier Film Formation Using a Metal Halide and Products Thereof

    DTIC Science & Technology

    1998-08-20

    structure of the barrier film on an atomic level where the barrier film is comprised of a plurality of contiguous monolayers, while FIG. 7B shows...another embodiment where the barrier film is comprised of a plurality of i contiguous monolayers in which different monolayers thereof are formed... effusion cell, for example a barium fluoride, strontium fluoride or the like effusion cell, is provided at 32, and has a shutter 33. A 15 shutter 35

  14. Nano-stepper-driven optical shutter for applications in free-space micro-optics

    NASA Astrophysics Data System (ADS)

    Zawadzka, Justyna; Li, Lijie; Unamuno, Anartz; Uttamchandani, Deepak G.

    2002-09-01

    In this paper we report a simple design of a micro-optical shutter/attenuator. The standard MUMPS process was used to fabricate the device. A vertically erected, gold-coated, 200x300 mm side length micro-mirror was precisely placed between the end faces of two closely spaced optical fibers. The position of the micro-mirror with respect to the optical fiber end face was controlled by a nano-stepping motor array. Optical and mechanical tests were performed on the device. A 1.55 mm laser beam was sent along the optical fiber. When the micro-mirror was removed from the front of the fiber, the coupling efficiency between two fibers was -10 dBm. Once the micro-mirror was placed in the optical path the coupling efficiency dropped to -51.5 dBm. The best attenuation was obtained when the micro-mirror blocked the whole cross-section of the laser beam diameter. It is evident that the device can operate as a high precision fiber optic attenuator or shutter.

  15. HIGH SPEED KERR CELL FRAMING CAMERA

    DOEpatents

    Goss, W.C.; Gilley, L.F.

    1964-01-01

    The present invention relates to a high speed camera utilizing a Kerr cell shutter and a novel optical delay system having no moving parts. The camera can selectively photograph at least 6 frames within 9 x 10/sup -8/ seconds during any such time interval of an occurring event. The invention utilizes particularly an optical system which views and transmits 6 images of an event to a multi-channeled optical delay relay system. The delay relay system has optical paths of successively increased length in whole multiples of the first channel optical path length, into which optical paths the 6 images are transmitted. The successively delayed images are accepted from the exit of the delay relay system by an optical image focusing means, which in turn directs the images into a Kerr cell shutter disposed to intercept the image paths. A camera is disposed to simultaneously view and record the 6 images during a single exposure of the Kerr cell shutter. (AEC)

  16. On The Design and Implementation of a New Electric-Field Meter with Reciprocating Shutter and Field-Change-Antenna Option

    NASA Astrophysics Data System (ADS)

    Swenson, J.; Byerley, L. G.; Bogoev, I.; Hinckley, A.; Beasley, W. H.

    2003-12-01

    The atmospheric electric field is a unique indicator of locally disturbed weather, local thunderstorms and local atmospheric electrical hazards. Yet, surprisingly, routine observations of ambient electric field have never been included in the canonical suite of measured meteorological variables. This notable omission may be a result of the historically high costs to acquire, install, and maintain conventional electric-field mills. To reduce costs and overcome limitations of traditional field meters, Campbell Scientific, Inc. has developed an electric-field meter (patent pending) with a reciprocating shutter that eliminates the problem of making electrical contact with a rotating shaft. The reciprocating action is under microprocessor control, so the sample rate can be varied in response to measured conditions. Between samples of electric field, the shutter can even be left open indefinitely, allowing the instrument to function as a field-change antenna. Since the shutter is closed before and after each measurement in field-meter mode, it is relatively easy to account for drift and offsets automatically, so that measurements can be made even if the electrode insulator becomes degraded by conductive deposits of the types likely to be encountered in severe outdoor environments. Because the motor is energized for only a small fraction of each measurement cycle, average power consumption is exceptionally low, making the new field meter especially suitable for solar-powered applications such as automated remote meteorological stations. Some preliminary observations demonstrate the capabilities of the instrument.

  17. Visible light communication based vehicle positioning using LED street light and rolling shutter CMOS sensors

    NASA Astrophysics Data System (ADS)

    Do, Trong Hop; Yoo, Myungsik

    2018-01-01

    This paper proposes a vehicle positioning system using LED street lights and two rolling shutter CMOS sensor cameras. In this system, identification codes for the LED street lights are transmitted to camera-equipped vehicles through a visible light communication (VLC) channel. Given that the camera parameters are known, the positions of the vehicles are determined based on the geometric relationship between the coordinates of the LEDs in the images and their real world coordinates, which are obtained through the LED identification codes. The main contributions of the paper are twofold. First, the collinear arrangement of the LED street lights makes traditional camera-based positioning algorithms fail to determine the position of the vehicles. In this paper, an algorithm is proposed to fuse data received from the two cameras attached to the vehicles in order to solve the collinearity problem of the LEDs. Second, the rolling shutter mechanism of the CMOS sensors combined with the movement of the vehicles creates image artifacts that may severely degrade the positioning accuracy. This paper also proposes a method to compensate for the rolling shutter artifact, and a high positioning accuracy can be achieved even when the vehicle is moving at high speeds. The performance of the proposed positioning system corresponding to different system parameters is examined by conducting Matlab simulations. Small-scale experiments are also conducted to study the performance of the proposed algorithm in real applications.

  18. Interactive binocular treatment (I-BiT) for amblyopia: results of a pilot study of 3D shutter glasses system.

    PubMed

    Herbison, N; Cobb, S; Gregson, R; Ash, I; Eastgate, R; Purdy, J; Hepburn, T; MacKeith, D; Foss, A

    2013-09-01

    A computer-based interactive binocular treatment system (I-BiT) for amblyopia has been developed, which utilises commercially available 3D 'shutter glasses'. The purpose of this pilot study was to report the effect of treatment on visual acuity (VA) in children with amblyopia. Thirty minutes of I-BiT treatment was given once weekly for 6 weeks. Treatment sessions consisted of playing a computer game and watching a DVD through the I-BiT system. VA was assessed at baseline, mid-treatment, at the end of treatment, and at 4 weeks post treatment. Standard summary statistics and an exploratory one-way analysis of variance (ANOVA) were performed. Ten patients were enrolled with strabismic, anisometropic, or mixed amblyopia. The mean age was 5.4 years. Nine patients (90%) completed the full course of I-BiT treatment with a mean improvement of 0.18 (SD=0.143). Six out of nine patients (67%) who completed the treatment showed a clinically significant improvement of 0.125 LogMAR units or more at follow-up. The exploratory one-way ANOVA showed an overall effect over time (F=7.95, P=0.01). No adverse effects were reported. This small, uncontrolled study has shown VA gains with 3 hours of I-BiT treatment. Although it is recognised that this pilot study had significant limitations-it was unblinded, uncontrolled, and too small to permit formal statistical analysis-these results suggest that further investigation of I-BiT treatment is worthwhile.

  19. Detection of carcinogenic metals in kidney stones using ultraviolet laser-induced breakdown spectroscopy.

    PubMed

    Khalil, Ahmed Asaad I; Gondal, Mohammed A; Shemis, Mohamed; Khan, Irfan S

    2015-03-10

    The UV single-pulsed (SP) laser-induced breakdown spectroscopy (LIBS) system was developed to detect the carcinogenic metals in human kidney stones extracted through the surgical operation. A neodymium yttrium aluminium garnet laser operating at 266 nm wavelength and 20 Hz repetition rate along with a spectrometer interfaced with an intensified CCD (ICCD) was applied for spectral analysis of kidney stones. The ICCD camera shutter was synchronized with the laser-trigger pulse and the effect of laser energy and delay time on LIBS signal intensity was investigated. The experimental parameters were optimized to obtain the LIBS plasma in local thermodynamic equilibrium. Laser energy was varied from 25 to 50 mJ in order to enhance the LIBS signal intensity and attain the best signal to noise ratio. The parametric dependence studies were important to improve the limit of detection of trace amounts of toxic elements present inside stones. The carcinogenic metals detected in kidney stones were chromium, cadmium, lead, zinc, phosphate, and vanadium. The results achieved from LIBS system were also compared with the inductively coupled plasma-mass spectrometry analysis and the concentration detected with both techniques was in very good agreement. The plasma parameters (electron temperature and density) for SP-LIBS system were also studied and their dependence on incident laser energy and delay time was investigated as well.

  20. Comparison of built environment adaptations to heat exposure and mortality during hot weather, West Midlands region, UK.

    PubMed

    Taylor, Jonathon; Wilkinson, Paul; Picetti, Roberto; Symonds, Phil; Heaviside, Clare; Macintyre, Helen L; Davies, Michael; Mavrogianni, Anna; Hutchinson, Emma

    2018-02-01

    There is growing recognition of the need to improve protection against the adverse health effects of hot weather in the context of climate change. We quantify the impact of the Urban Heat Island (UHI) and selected adaptation measures made to dwellings on temperature exposure and mortality in the West Midlands region of the UK. We used 1) building physics models to assess indoor temperatures, initially in the existing housing stock and then following adaptation measures (energy efficiency building fabric upgrades and/or window shutters), of representative dwelling archetypes using data from the English Housing Survey (EHS), and 2) modelled UHI effect on outdoor temperatures. The ages of residents were combined with evidence on the heat-mortality relationship to estimate mortality risk and to quantify population-level changes in risk following adaptations to reduce summertime heat exposure. Results indicate that the UHI effect accounts for an estimated 21% of mortality. External shutters may reduce heat-related mortality by 30-60% depending on weather conditions, while shutters in conjunction with energy-efficient retrofitting may reduce risk by up to 52%. The use of shutters appears to be one of the most effective measures providing protection against heat-related mortality during periods of high summer temperatures, although their effectiveness may be limited under extreme temperatures. Energy efficiency adaptations to the dwellings and measures to increase green space in the urban environment to combat the UHI effect appear to be less beneficial for reducing heat-related mortality. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Low energy high angular resolution neutral atom detection by means of micro-shuttering techniques: the BepiColombo SERENA/ELENA sensor

    NASA Astrophysics Data System (ADS)

    Orsini, S.; di Lellis, A. M.; Milillo, A.; de Angelis, E.; Mura, A.; Selci, S.; Dandouras, I.; Cerulli-Irelli, P.; Leoni, R.; Mangano, V.; Massetti, S.; Mattioli, F.; Orfei, R.; Austin, C.; Medale, J.-L.; Vertolli, N.; di Giulio, D.

    2009-06-01

    The neutral sensor ELENA (Emitted Low-Energy Neutral Atoms) for the ESA cornerstone BepiColombo mission to Mercury (in the SERENA instrument package) is a new kind of low energetic neutral atoms instrument, mostly devoted to sputtering emission from planetary surfaces, from E~20 eV up to E~5 keV, within 1-D (2°×76°). ELENA is a Time-of-Flight (TOF) system, based on oscillating shutter (operated at frequencies up to a 100 kHz) and mechanical gratings: the incoming neutral particles directly impinge upon the entrance with a definite timing (START) and arrive to a STOP detector after a flight path. After a brief dissertation on the achievable scientific objectives, this paper describes the instrument, with the new design techniques approached for the neutral particles identification and the nano-techniques used for designing and manufacturing the nano-structure shuttering core of the ELENA sensor. The expected count-rates, based on the Hermean environment features, are shortly presented and discussed. Such design technologies could be fruitfully exported to different applications for planetary exploration.

  2. Shutter heating system of Antarctic bright star survey telescope

    NASA Astrophysics Data System (ADS)

    Chen, Jie; Dong, Shucheng; Jiang, Fengxin; Zhang, Hongfei; Wang, Jian

    2016-07-01

    A heat preservation system for mechanical shutter in Antarctic is introduced in the paper. The system consists of the heat preservation chamber, the host controller STM32F103C8T6 with peripheral circuit and the control algorithm. The whole design is carried out on the basis of the low temperature requirement, including the cavity structure and thermal insulation. The heat preservation chamber is used to keep the shutter warm and support the weight of the camera. Using PT100 as the temperature sensor, the signal processing circuit converts the temperature to the voltage which is then digitized by the 12 bit ADC in the STM32. The host controller transforms the voltage data into temperature, and through the tuning of the Fussy PID algorithm which controls the duty cycle of the MOSFET, the temperature control of chamber is realized. The System has been tested in the cryogenic environment for a long time, with characteristic of low temperature resistance, small volume, high accuracy of temperature control as well as remote control and detection.

  3. Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics

    NASA Technical Reports Server (NTRS)

    Nguyen, Quang-Viet; Fischer, David G.; Kojima, Jun

    2011-01-01

    Accurate experimental measurement of spatially and temporally resolved variations in chemical composition (species concentrations) and temperature in turbulent flames is vital for characterizing the complex phenomena occurring in most practical combustion systems. These diagnostic measurements are called multiscalar because they are capable of acquiring multiple scalar quantities simultaneously. Multiscalar diagnostics also play a critical role in the area of computational code validation. In order to improve the design of combustion devices, computational codes for modeling turbulent combustion are often used to speed up and optimize the development process. The experimental validation of these codes is a critical step in accepting their predictions for engine performance in the absence of cost-prohibitive testing. One of the most critical aspects of setting up a time-resolved stimulated Raman scattering (SRS) diagnostic system is the temporal optical gating scheme. A short optical gate is necessary in order for weak SRS signals to be detected with a good signal- to-noise ratio (SNR) in the presence of strong background optical emissions. This time-synchronized optical gating is a classical problem even to other spectroscopic techniques such as laser-induced fluorescence (LIF) or laser-induced breakdown spectroscopy (LIBS). Traditionally, experimenters have had basically two options for gating: (1) an electronic means of gating using an image intensifier before the charge-coupled-device (CCD), or (2) a mechanical optical shutter (a rotary chopper/mechanical shutter combination). A new diagnostic technology has been developed at the NASA Glenn Research Center that utilizes a frame-transfer CCD sensor, in conjunction with a pulsed laser and multiplex optical fiber collection, to realize time-resolved Raman spectroscopy of turbulent flames that is free from optical background noise (interference). The technology permits not only shorter temporal optical gating (down to <1 s, in principle), but also higher optical throughput, thus resulting in a substantial increase in measurement SNR.

  4. Controlled environment vitrification system for preparation of liquids

    DOEpatents

    Bellare, Jayesh R.; Davis, Howard T.; Scriven, II, L. Edward; Talmon, Yeshayahu

    1988-01-01

    A system for preparing specimens in a controlled environment to insure that a liquid or partially liquid specimen is maintained in its original state while it is being prepared, and once prepared the specimen is vitrified or solidified with minimal alteration of its microstructure. The controlled environment is provided within a chamber where humidity and temperature can be controlled precisely while the specimen is prepared. The specimen is mounted on a plunger and a shutter controlled opening is opened substantially simultaneously with release of the plunger so the specimen is propelled through the shutter into an adjacent cryogenic bath.

  5. Controlled environment vitrification system for preparation of liquids

    DOEpatents

    Bellare, J.R.; Davis, H.T.; Scriven, L.E. II; Talmon, Y.

    1988-06-28

    A system is described for preparing specimens in a controlled environment to insure that a liquid or partially liquid specimen is maintained in its original state while it is being prepared, and once prepared the specimen is vitrified or solidified with minimal alteration of its microstructure. The controlled environment is provided within a chamber where humidity and temperature can be controlled precisely while the specimen is prepared. The specimen is mounted on a plunger and a shutter controlled opening is opened substantially simultaneously with release of the plunger so the specimen is propelled through the shutter into an adjacent cryogenic bath. 7 figs.

  6. Applicability of post-ionization theory to laser-assisted field evaporation of magnetite

    DOE PAGES

    Schreiber, Daniel K.; Chiaramonti, Ann N.; Gordon, Lyle M.; ...

    2014-12-15

    Analysis of the mean Fe ion charge state from laser-assisted field evaporation of magnetite (Fe3O4) reveals unexpected trends as a function of laser pulse energy that break from conventional post-ionization theory for metals. For Fe ions evaporated from magnetite, the effects of post-ionization are partially offset by the increased prevalence of direct evaporation into higher charge states with increasing laser pulse energy. Therefore the final charge state is related to both the field strength and the laser pulse energy, despite those variables themselves being intertwined when analyzing at a constant detection rate. Comparison of data collected at different base temperaturesmore » also show that the increased prevalence of Fe2+ at higher laser energies is possibly not a direct thermal effect. Conversely, the ratio of 16O+:16O2+ is well-correlated with field strength and unaffected by laser pulse energy on its own, making it a better overall indicator of the field evaporation conditions than the mean Fe charge state. Plotting the normalized field strength versus laser pulse energy also elucidates a non-linear dependence, in agreement with previous observations on semiconductors, that suggests a field-dependent laser absorption efficiency. Together these observations demonstrate that the field evaporation process for laser-pulsed oxides exhibits fundamental differences from metallic specimens that cannot be completely explained by post-ionization theory. Further theoretical studies, combined with detailed analytical observations, are required to understand fully the field evaporation process of non-metallic samples.« less

  7. Pulse Shaped 8-PSK Bandwidth Efficiency and Spectral Spike Elimination

    NASA Technical Reports Server (NTRS)

    Tao, Jian-Ping

    1998-01-01

    The most bandwidth-efficient communication methods are imperative to cope with the congested frequency bands. Pulse shaping methods have excellent effects on narrowing bandwidth and increasing band utilization. The position of the baseband filters for the pulse shaping is crucial. Post-modulation pulse shaping (a low pass filter is located after the modulator) can change signals from constant envelope to non-constant envelope, and non-constant envelope signals through non-linear device (a SSPA or TWT) can further spread the power spectra. Pre-modulation pulse shaping (a filter is located before the modulator) will have constant envelope. These two pulse shaping methods have different effects on narrowing the bandwidth and producing bit errors. This report studied the effect of various pre-modulation pulse shaping filters with respect to bandwidth, spectral spikes and bit error rate. A pre-modulation pulse shaped 8-ary Phase Shift Keying (8PSK) modulation was used throughout the simulations. In addition to traditional pulse shaping filters, such as Bessel, Butterworth and Square Root Raised Cosine (SRRC), other kinds of filters or pulse waveforms were also studied in the pre-modulation pulse shaping method. Simulations were conducted by using the Signal Processing Worksystem (SPW) software package on HP workstations which simulated the power spectral density of pulse shaped 8-PSK signals, end to end system performance and bit error rates (BERS) as a function of Eb/No using pulse shaping in an AWGN channel. These results are compared with the post-modulation pulse shaped 8-PSK results. The simulations indicate traditional pulse shaping filters used in pre-modulation pulse shaping may produce narrower bandwidth, but with worse BER than those in post-modulation pulse shaping. Theory and simulations show pre- modulation pulse shaping could also produce discrete line power spectra (spikes) at regular frequency intervals. These spikes may cause interference with adjacent channel and reduce power efficiency. Some particular pulses (filters), such as trapezoid and pulses with different transits (such as weighted raised cosine transit) were found to reduce bandwidth and not generate spectral spikes. Although a solid state power amplifier (SSPA) was simulated in the non-linear (saturation) region, output power spectra did not spread due to the constant envelope 8-PSK signals.

  8. Effect of 830 nm Diode Laser Irradiation of Root Canal on Bond Strength of Metal and Fiber Post.

    PubMed

    Strefezza, Claudia; Amaral, Marcello Magri; Quinto, José; Gouw-Soares, Sheila Cynthia; Zamataro, Claudia Bianchi; Zezell, Denise Maria

    2018-05-16

    The correct selections of the cementing agent, the endodontic post material and placement protocol are critical to provide an increased longevity of the teeth that went through endodontic treatment. The irradiation with diode laser before post cementation, can promote an antimicrobial effect. However, there is a lack of information about the effect of 830 nm diode laser on the post bond strength. This study analyzed the effect of dentin root canal irradiation with high-intensity diode laser, at 830 nm, operating in continuous or pulsed mode, on the retention of metal or fiber posts, cemented with self-etching resinous composite (Panavia F) and zinc phosphate cement (ZnPO 4 ). Human roots were irradiated with diode laser (continuous and pulsed mode). The fiber posts were luted with Panavia F and the metal posts with Panavia F or ZnPO 4 cement. Specimens were sectioned into three sections (cervical, middle, and apical). The bond strength was measured by a push-out mechanical analysis. For the statistical analysis, a three-way ANOVA test was applied following a Tukey's pairwise comparison with a significance level of p = 0.05. The irradiated groups presented higher bond strength compared with nonirradiated group (p < 0.05), and the cervical and middle thirds presented higher on bond strength than the apical. The association of metal post and Panavia F presented higher bond strength when irradiated on continuous mode (p < 0.05). Fiber post and Panavia F presented higher bond strength associated to pulsed mode. The mode seems not to make a significant difference. These results corroborate the importance of the post bond to dentin and root canal debris removal to increase the tooth longevity. It was shown that the dentin to post bond strength were enhanced by the diode laser irradiation either on continuous or pulsed modes.

  9. Development of a pepper pot emittance probe and its application for ECR ion beam studies.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kondrashev, S.; Barcikowski, A.; Mustapha, B.

    2009-07-21

    A pepper pot-scintillator screen system has been developed and used to measure the emittance of DC ion beams extracted from a high-intensity permanent magnet ECR ion source. The system includes a fast beam shutter with a minimum dwell time of 18 ms to reduce the degradation of the CsI(Tl) scintillator by DC ion beam irradiation and a CCD camera with a variable shutter speed in the range of 1 {micro}s-65 s. On-line emittance measurements are performed by an application code developed on a LabVIEW platform. The sensitivity of the device is sufficient to measure the emittance of DC ion beamsmore » with current densities down to about 100 nA/cm{sup 2}. The emittance of all ion species extracted from the ECR ion source and post-accelerated to an energy of 75-90 keV/charge have been measured downstream of the LEBT. As the mass-to-charge ratio of ion species increases, the normalized RMS emittances in both transverse phase planes decrease from 0.5-1.0 {pi} mm mrad for light ions to 0.05-0.09 {pi} mm mrad for highly charged {sup 209}Bi ions. The dependence of the emittance on ion's mass-to-charge ratio follows very well the dependence expected from beam rotation induced by decreasing ECR axial magnetic field. The measured emittance values cannot be explained by only ion beam rotation for all ion species and the contribution to emittance of ion temperature in plasma, non-linear electric fields and non-linear space charge is comparable or even higher than the contribution of ion beam rotation.« less

  10. Evaluation of peripheral perfusion in term newborns before and after Yintang (EX-HN 3) massage.

    PubMed

    Tugcu, Ali Ulas; Cabioglu, Tugrul; Abbasoglu, Aslihan; Ecevit, Ayse; Ince, Deniz Anuk; Tarcan, Aylin

    2015-12-01

    To identify how acupressure on the acupoint Yintang (EX-HN 3) impacts oxygen saturation, pulse rate, and peripheral perfusion in term-born infants without underlying disease. Infants born between weeks 37 and 42 of gestation were included in this study. The polyclinic's neonatology room was noise-controlled and made half-dark to prevent the perfusion index from being confounded. A pulse oximeter was linked to the baby's left lower extremity. Acupressure was applied on Yintang (EX-HN 3) for 30 s clockwise, held for 30 s, and then acupressure was applied for another 30 s counterclockwise. The baby's SaO2, pulse rate, and perfusion index were recorded for each minute before and after acupressure. When pre- and post-acupressure pulse rate values were compared, a significant decrease in pulse rate values after acupressure application was observed. When pre- and post-acupressure oxygen saturation values were compared, a significant increase in post-acupressure oxygen saturation was observed. In addition, peripheral perfusion increased significantly after acupressure. Acupressure application has been used in traditional medicine for many years. However, it is not yet widely used in modern medicine. This study shows the impact of acupressure on neonatal skin perfusion, oxygen saturation, and pulse rate.

  11. Design and development of a large diameter high pressure fast acting propulsion valve and valve actuator

    NASA Technical Reports Server (NTRS)

    Srinivasan, K. V.

    1986-01-01

    The design and development of a large diameter high pressure quick acting propulsion valve and valve actuator is described. The valve is the heart of a major test facility dedicated to conducting full scale performance tests of aircraft landing systems. The valve opens in less than 300 milliseconds releasing a 46-centimeter- (18-in.-) diameter water jet and closes in 300 milliseconds. The four main components of the valve, i.e., valve body, safety shutter, high speed shutter, and pneumatic-hydraulic actuator, are discussed. This valve is unique and may have other aerospace and industrial applications.

  12. Performance evaluation of stereo endoscopic imaging system incorporating TFT-LCD.

    PubMed

    Song, C-G; Park, S-K

    2005-01-01

    This paper presents a 3D endoscopic video system designed to improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery. In a comparison of the polarized and electric shutter-type stereo imaging systems, the former was found to be superior in terms of both accuracy and speed for knot-tying and for the loop pass test. The results of our experiments show that the proposed 3D endoscopic system has a sufficiently wide viewing angle and zone for multi-viewing, and that it provides better image quality and more stable optical performance compared with the electric shutter-type.

  13. Design and Development of a Large Diameter, High Pressure, Fast Acting Propulsion Valve and Valve Actuator

    NASA Technical Reports Server (NTRS)

    Srinivasan, K. V.

    1986-01-01

    This paper describes the design and development of a large diameter high pressure quick acting propulsion valve and valve actuator. The valve is the heart of a major test facility dedicated to conducting full scale performance tests of aircraft landing gear systems. The valve opens in less than 300 milliseconds releasing a 46 cm (18 in) diameter water jet and closes in 300 milliseconds. The four main components of the valve, i.e., valve body, safety shutter, high speed shutter, and pneumatic-hydraulic actuator, are discussed. This valve is unique and may have other aerospace and industrial applications.

  14. Phase elements by means of a photolithographic system employing a spatial light modulator

    NASA Astrophysics Data System (ADS)

    Aubrecht, Ivo; Miler, Miroslav; Pala, Jan

    2003-07-01

    The system employs a spatial light modulator (SLM), between a pair of crossed polarizers, and an electronic shutter. Transmission of the SLM with the polarizers is controlled by graphical software that defines which pixels are fully transparent and which are fully opaque. While a particular binary graphics is on the SLM the electronic shutter allows light to pass for a certain time. The graphics is imaged, by an objective, onto a photoresist plate. A mercury lamp is used as a light source. The graphics changes after each exposition and the whole sequence of images determines the resultant surface-relief modulation.

  15. Single-event transient imaging with an ultra-high-speed temporally compressive multi-aperture CMOS image sensor.

    PubMed

    Mochizuki, Futa; Kagawa, Keiichiro; Okihara, Shin-ichiro; Seo, Min-Woong; Zhang, Bo; Takasawa, Taishi; Yasutomi, Keita; Kawahito, Shoji

    2016-02-22

    In the work described in this paper, an image reproduction scheme with an ultra-high-speed temporally compressive multi-aperture CMOS image sensor was demonstrated. The sensor captures an object by compressing a sequence of images with focal-plane temporally random-coded shutters, followed by reconstruction of time-resolved images. Because signals are modulated pixel-by-pixel during capturing, the maximum frame rate is defined only by the charge transfer speed and can thus be higher than those of conventional ultra-high-speed cameras. The frame rate and optical efficiency of the multi-aperture scheme are discussed. To demonstrate the proposed imaging method, a 5×3 multi-aperture image sensor was fabricated. The average rising and falling times of the shutters were 1.53 ns and 1.69 ns, respectively. The maximum skew among the shutters was 3 ns. The sensor observed plasma emission by compressing it to 15 frames, and a series of 32 images at 200 Mfps was reconstructed. In the experiment, by correcting disparities and considering temporal pixel responses, artifacts in the reconstructed images were reduced. An improvement in PSNR from 25.8 dB to 30.8 dB was confirmed in simulations.

  16. Programmable optical microshutter arrays for large aspect ratio microslits

    NASA Astrophysics Data System (ADS)

    Ilias, S.; Picard, F.; Larouche, C.; Kruzelecky, R.; Jamroz, W.; Le Noc, L.; Topart, P.

    2008-06-01

    Design, fabrication and characterization of a 16x1 programmable microshutter array are described. Each shutter controls the light transmitted through a microslit defined on the transparent substrate supporting the array. Two approaches were considered for the shutter array implementation: sweeping blades and zipping actuators. Simulation results and fabrication constraints led to the selection of the zipping actuators. The device was fabricated using a surface micromachining process. Each microshutter is basically an electrostatic zipping actuator having a curved shape induced by a stress gradient throughout the actuator thickness. When a sufficient voltage is applied between the microshutter and an actuation electrode surrounding the microslit area, the generated electrostatic force pulls the actuator down to the substrate which closes the microslit. Opening the slit relies on the restoring force due to the actuator deformation. Microshutter arrays were fabricated successfully. High light transmission through the slit area is obtained with the actuator in the open position and excellent light blocking is observed when the shutter is closed. Static and dynamic responses of the device were determined. A pull-in voltage of about 110 V closes the microslit and the response times to close and open the microslit are about 2 and 7 ms, respectively.

  17. Growth and Properties of Lattice Matched GaAsSbN Epilayer on GaAs for Solar Cell Applications

    NASA Technical Reports Server (NTRS)

    Bharatan, Sudhakar; Iyer, Shanthi; Matney, Kevin; Collis, Ward J.; Nunna Kalyan; Li, Jia; Wu, Liangjin; McGuire, Kristopher; McNeil, Laurie E.

    2006-01-01

    The growth and properties of GaAsSbN single quantum wells (SQWs) are investigated in this work. The heterostructures were grown on GaAs substrates in an elemental solid source molecular beam epitaxy (MBE) system assisted with a RF plasma nitrogen source. A systematic study has been carried out to determine the influence of various growth conditions, such as the growth temperature and the source shutter-opening sequence, on the quality of the grown layers and the incorporation of N and Sb. The effects of ex situ and in situ annealing under As overpressure on the optical properties of the layers have also been investigated. Substrate temperature in the range of 450-470 C was found to be optimum. Simultaneous opening of the source shutters was found to yield sharper QW interfaces. N and Sb incorporations were found to depend strongly upon substrate temperatures and source shutter opening sequences. A significant increase in PL intensity with a narrowing of PL line shape and blue shift in emission energy were observed on annealing the GaAsSbN/GaAs SQW, with in situ annealing under As overpressure providing better results, compared to ex situ annealing.

  18. Pulsed Dose Radiofrequency Before Ablation of Medial Branch of the Lumbar Dorsal Ramus for Zygapophyseal Joint Pain Reduces Post-procedural Pain.

    PubMed

    Arsanious, David; Gage, Emmanuel; Koning, Jonathon; Sarhan, Mazin; Chaiban, Gassan; Almualim, Mohammed; Atallah, Joseph

    2016-01-01

    One of the potential side effects with radiofrequency ablation (RFA) includes painful cutaneous dysesthesias and increased pain due to neuritis or neurogenic inflammation. This pain may require the prescription of opioids or non-opioid analgesics to control post-procedural pain and discomfort. The goal of this study is to compare post-procedural pain scores and post-procedural oral analgesic use in patients receiving continuous thermal radiofrequency ablation versus patients receiving pulsed dose radiofrequency immediately followed by continuous thermal radiofrequency ablation for zygopophaseal joint disease. This is a prospective, double-blinded, randomized, controlled trial. Patients who met all the inclusion criteria and were not subject to any of the exclusion criteria were required to have two positive diagnostic medial branch blocks prior to undergoing randomization, intervention, and analysis. University hospital. Eligible patients were randomized in a 1:1 ratio to either receive thermal radiofrequency ablation alone (standard group) or pulsed dose radiofrequency (PDRF) immediately followed by thermal radiofrequency ablation (investigational group), all of which were performed by a single Board Certified Pain Medicine physician. Post-procedural pain levels between the two groups were assessed using the numerical pain Scale (NPS), and patients were contacted by phone on post-procedural days 1 and 2 in the morning and afternoon regarding the amount of oral analgesic medications used in the first 48 hours following the procedure. Patients who received pulsed dose radiofrequency followed by continuous radiofrequency neurotomy reported statistically significantly lower post-procedural pain scores in the first 24 hours compared to patients who received thermal radiofrequency neurotomy alone. These patients also used less oral analgesic medication in the post-procedural period. These interventions were carried out by one board accredited pain physician at one center. The procedures were exclusively performed using one model of radiofrequency generator, at one setting for the PDRF and RFA. The difference in the number of levels of ablation was not considered in the analysis of the results. Treating patients with pulsed dose radiofrequency prior to continuous thermal radiofrequency ablation can provide patients with less post-procedural pain during the first 24 hours and also reduce analgesic requirements. Furthermore, the addition of PDRF to standard thermal RFA did not prolong the time of standard thermal radiofrequency ablation procedures, as it was performed during the typically allotted time for local anesthetic action. Low back pain, facet joint disease, medial branch block, Radiofrequency ablation, thermal radiofrequency, pulsed dose radiofrequency, PDRF, zygapophyseal joint.

  19. Chronic effects of an environmentally-relevant, short-term neonicotinoid insecticide pulse on four aquatic invertebrates.

    PubMed

    Raby, Melanie; Zhao, Xiaoming; Hao, Chunyan; Poirier, David G; Sibley, Paul K

    2018-10-15

    Neonicotinoid insecticides used in agriculture can enter freshwater environments in pulses; that is, a short-term period of a higher concentration, followed by a period of a comparatively lower concentration. Non-target aquatic arthropods are exposed to these fluctuating concentrations of neonicotinoids. The present study investigated the potential latent effects of a single environmentally-relevant 24-h pulse of imidacloprid and thiamethoxam, in separate experiments, on the early life-stages of four aquatic arthropods (Hyalella azteca, Chironomus dilutus, Hexagenia spp., and Neocloeon triangulifer). At least three nominal pulse concentrations were tested for each neonicotinoid-species combination: 2.5, 5, and 10 μg L -1 , which were based on environmental monitoring in Ontario, Canada. After exposure to the pulse, organisms were assessed for survival and immobilization. Surviving organisms were then moved into clean water for a chronic post-treatment period, where endpoints including survival, growth, reproduction or emergence, depending on the species, were evaluated. Immediately after the 24-h pulse, immobilization was seen in C. dilutus and N. triangulifer in the highest imidacloprid concentrations tested (8.8 and 8.9 μg L -1 , respectively). After transfer to clean water, immobilized organisms recovered, and no latent toxicity was seen for any of the evaluated endpoints. H. azteca and Hexagenia spp. showed no effects immediately after the imidacloprid pulse, or after the chronic post-treatment period. No effects were seen in any species after the thiamethoxam pulse, or the post-treatment period. The present study shows that toxic effects due to short-term pulse exposures of ~9 μg L -1 imidacloprid can occur in sensitive insect species. However, organisms can recover when the stressor ceases, with no long-term effects on test organisms. Copyright © 2018. Published by Elsevier B.V.

  20. TMS effects on subjective and objective measures of vision: stimulation intensity and pre- versus post-stimulus masking.

    PubMed

    de Graaf, Tom A; Cornelsen, Sonja; Jacobs, Christianne; Sack, Alexander T

    2011-12-01

    Transcranial magnetic stimulation (TMS) can be used to mask visual stimuli, disrupting visual task performance or preventing visual awareness. While TMS masking studies generally fix stimulation intensity, we hypothesized that varying the intensity of TMS pulses in a masking paradigm might inform several ongoing debates concerning TMS disruption of vision as measured subjectively versus objectively, and pre-stimulus (forward) versus post-stimulus (backward) TMS masking. We here show that both pre-stimulus TMS pulses and post-stimulus TMS pulses could strongly mask visual stimuli. We found no dissociations between TMS effects on the subjective and objective measures of vision for any masking window or intensity, ruling out the option that TMS intensity levels determine whether dissociations between subjective and objective vision are obtained. For the post-stimulus time window particularly, we suggest that these data provide new constraints for (e.g. recurrent) models of vision and visual awareness. Finally, our data are in line with the idea that pre-stimulus masking operates differently from conventional post-stimulus masking. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Post-filament self-trapping of ultrashort laser pulses.

    PubMed

    Mitrofanov, A V; Voronin, A A; Sidorov-Biryukov, D A; Andriukaitis, G; Flöry, T; Pugžlys, A; Fedotov, A B; Mikhailova, J M; Panchenko, V Ya; Baltuška, A; Zheltikov, A M

    2014-08-15

    Laser filamentation is understood to be self-channeling of intense ultrashort laser pulses achieved when the self-focusing because of the Kerr nonlinearity is balanced by ionization-induced defocusing. Here, we show that, right behind the ionized region of a laser filament, ultrashort laser pulses can couple into a much longer light channel, where a stable self-guiding spatial mode is sustained by the saturable self-focusing nonlinearity. In the limiting regime of negligibly low ionization, this post-filamentation beam dynamics converges to a large-scale beam self-trapping scenario known since the pioneering work on saturable self-focusing nonlinearities.

  2. Optimization of the open-loop liquid crystal adaptive optics retinal imaging system

    NASA Astrophysics Data System (ADS)

    Kong, Ningning; Li, Chao; Xia, Mingliang; Li, Dayu; Qi, Yue; Xuan, Li

    2012-02-01

    An open-loop adaptive optics (AO) system for retinal imaging was constructed using a liquid crystal spatial light modulator (LC-SLM) as the wavefront compensator. Due to the dispersion of the LC-SLM, there was only one illumination source for both aberration detection and retinal imaging in this system. To increase the field of view (FOV) for retinal imaging, a modified mechanical shutter was integrated into the illumination channel to control the size of the illumination spot on the fundus. The AO loop was operated in a pulsing mode, and the fundus was illuminated twice by two laser impulses in a single AO correction loop. As a result, the FOV for retinal imaging was increased to 1.7-deg without compromising the aberration detection accuracy. The correction precision of the open-loop AO system was evaluated in a closed-loop configuration; the residual error is approximately 0.0909λ (root-mean-square, RMS), and the Strehl ratio ranges to 0.7217. Two subjects with differing rates of myopia (-3D and -5D) were tested. High-resolution images of capillaries and photoreceptors were obtained.

  3. a Portable Pixel Detector Operating as AN Active Nuclear Emulsion and its Application for X-Ray and Neutron Tomography

    NASA Astrophysics Data System (ADS)

    Vykydal, Z.; Jakubek, J.; Holy, T.; Pospisil, S.

    2006-04-01

    This work is devoted to the development of a USB1.1 (Universal Serial Bus) based read out system for the Medipix2 detector to achieve maximum portability of this position sensitive detecting device. All necessary detector support is integrated into one compact system (80 × 50 × 20 mm3) including the detector bias source (up to 100 V). The read out interface can control external I2C based devices, so in case of tomography it is easy to synchronize detector shutter with stepper motor control. An additional significant advantage of the USB interface is the support of back side pulse processing. This feature enables to determine the energy additionally to the position of a heavy charged particle hitting the sensor. Due to the small pixel dimensions it is also possible to distinguish the type of single quanta of radiation from the track created in the pixel detector as in case of an active nuclear emulsion.

  4. Novel methods for measuring afterglow in developmental scintillators for X-ray and neutron detection

    NASA Astrophysics Data System (ADS)

    Bartle, C. M.; Edgar, A.; Dixie, L.; Varoy, C.; Piltz, R.; Buchanan, S.; Rutherford, K.

    2011-09-01

    In this paper we discuss two novel methods of measuring afterglow in scintillators. One method is designed for X-ray detection and the other for neutron detection applications. In the first method a commercial fan-beam scanner of basic design similar to those seen at airports is used to deliver a typically 12 ms long X-ray pulse to a scintillator by passing the test equipment through the scanner on the conveyor belt. In the second method the thermal neutron beam from a research reactor is incident on the scintillator. The beam is cut-off in about 1 ms using a 10B impregnated aluminum pneumatic shutter, and the afterglow is recorded on a dual range storage oscilloscope to capture both the steady state intensity and the weak decay. We describe these measurement methods and the results obtained for a range of developmental ceramic and glass scintillators, as well as some standard scintillators such as NaI(Tl), LiI(Eu) and the plastic scintillator NE102A. Preliminary modeling of the afterglow is presented.

  5. Spectroscopic studies of model photo-receptors: validation of a nanosecond time-resolved micro-spectrophotometer design using photoactive yellow protein and α-phycoerythrocyanin.

    PubMed

    Purwar, Namrta; Tenboer, Jason; Tripathi, Shailesh; Schmidt, Marius

    2013-09-13

    Time-resolved spectroscopic experiments have been performed with protein in solution and in crystalline form using a newly designed microspectrophotometer. The time-resolution of these experiments can be as good as two nanoseconds (ns), which is the minimal response time of the image intensifier used. With the current setup, the effective time-resolution is about seven ns, determined mainly by the pulse duration of the nanosecond laser. The amount of protein required is small, on the order of 100 nanograms. Bleaching, which is an undesirable effect common to photoreceptor proteins, is minimized by using a millisecond shutter to avoid extensive exposure to the probing light. We investigate two model photoreceptors, photoactive yellow protein (PYP), and α-phycoerythrocyanin (α-PEC), on different time scales and at different temperatures. Relaxation times obtained from kinetic time-series of difference absorption spectra collected from PYP are consistent with previous results. The comparison with these results validates the capability of this spectrophotometer to deliver high quality time-resolved absorption spectra.

  6. Stroboscopic Vision as a Treatment for Space Motion Sickness

    NASA Technical Reports Server (NTRS)

    Reschke, Millard F.; Somers, Jeffrey T.; Ford, George; Krnavek, Jody M.

    2007-01-01

    Results obtained from space flight indicate that most space crews will experience some symptoms of motion sickness causing significant impact on the operational objectives that must be accomplished to assure mission success. Based on the initial work of Melvill Jones we have evaluated stroboscopic vision as a method of preventing motion sickness. Given that the data presented by professor Melvill Jones were primarily post hoc results following a study not designed to investigate motion sickness, it is unclear how motion sickness results were actually determined. Building on these original results, we undertook a three part study that was designed to investigate the effect of stroboscopic vision (either with a strobe light or LCD shutter glasses) on motion sickness using: (1) visual field reversal, (2) Reading while riding in a car (with or without external vision present), and (3) making large pitch head movements during parabolic flight.

  7. Monte Carlo and analytical calculations for characterization of gas bremsstrahlung in ILSF insertion devices

    NASA Astrophysics Data System (ADS)

    Salimi, E.; Rahighi, J.; Sardari, D.; Mahdavi, S. R.; Lamehi Rachti, M.

    2014-12-01

    Gas bremsstrahlung is generated in high energy electron storage rings through interaction of the electron beam with the residual gas molecules in vacuum chamber. In this paper, Monte Carlo calculation has been performed to evaluate radiation hazard due to gas bremsstrahlung in the Iranian Light Source Facility (ILSF) insertion devices. Shutter/stopper dimensions is determined and dose rate from the photoneutrons via the giant resonance photonuclear reaction which takes place inside the shutter/stopper is also obtained. Some other characteristics of gas bremsstrahlung such as photon fluence, energy spectrum, angular distribution and equivalent dose in tissue equivalent phantom have also been investigated by FLUKA Monte Carlo code.

  8. High dynamic range CMOS (HDRC) imagers for safety systems

    NASA Astrophysics Data System (ADS)

    Strobel, Markus; Döttling, Dietmar

    2013-04-01

    The first part of this paper describes the high dynamic range CMOS (HDRC®) imager - a special type of CMOS image sensor with logarithmic response. The powerful property of a high dynamic range (HDR) image acquisition is detailed by mathematical definition and measurement of the optoelectronic conversion function (OECF) of two different HDRC imagers. Specific sensor parameters will be discussed including the pixel design for the global shutter readout. The second part will give an outline on the applications and requirements of cameras for industrial safety. Equipped with HDRC global shutter sensors SafetyEYE® is a high-performance stereo camera system for safe three-dimensional zone monitoring enabling new and more flexible solutions compared to existing safety guards.

  9. Characteristics of color optical shutter with dye-doped polymer network liquid crystal.

    PubMed

    Lee, G H; Hwang, K Y; Jang, J E; Jin, Y W; Lee, S Y; Jung, J E

    2011-03-01

    The optical properties and the theoretical prediction of color optical shutter with dye-doped polymer network liquid crystal (PNLC) were investigated. The view-angle dependence of reflectance according to the bias conditions showed distinctive characteristics, which could be explained from the effects of dye absorption and path length. It was also shown that the thickness dependence of reflectance was strongly influenced by the light-scattering coefficient. Our experimental results matched up well with the theoretical prediction based on the light scattering of liquid crystals in polymer network and the absorption of dichroic dye. This work indicates potential to improve the optical device using dye-doped liquid crystal-polymer composite.

  10. Fault tolerant function of dynamic refreshing holographic memory with shutter-less optical feedback circuit

    NASA Astrophysics Data System (ADS)

    Okamoto, Atsushi; Ito, Terumasa; Bunsen, Masatoshi; Takayama, Yoshihisa

    2005-11-01

    The optical system, consisting of two photorefractive memories and a shutter-less optical feedback circuit, will be demonstrated to function as data mirroring. This function is known to automatically detect the data dropout and restore data, using unimpaired data in another memory, in the event that part or all of the data in either of them were lost for some reason. This memory system also can cope with a damaged hologram, a result of reading beams, which is a disadvantage of rewritable photorefractive memory, to ensure non-destructive holographic reading. It can be achieved by using no electronic circuits or mechanical structures; our optical experimental method in particular obtains this basic action.

  11. Beam shuttering interferometer and method

    DOEpatents

    Deason, V.A.; Lassahn, G.D.

    1993-07-27

    A method and apparatus resulting in the simplification of phase shifting interferometry by eliminating the requirement to know the phase shift between interferograms or to keep the phase shift between interferograms constant. The present invention provides a simple, inexpensive means to shutter each independent beam of the interferometer in order to facilitate the data acquisition requirements for optical interferometry and phase shifting interferometry. By eliminating the requirement to know the phase shift between interferograms or to keep the phase shift constant, a simple, economical means and apparatus for performing the technique of phase shifting interferometry is provide which, by thermally expanding a fiber optical cable changes the optical path distance of one incident beam relative to another.

  12. Beam shuttering interferometer and method

    DOEpatents

    Deason, Vance A.; Lassahn, Gordon D.

    1993-01-01

    A method and apparatus resulting in the simplification of phase shifting interferometry by eliminating the requirement to know the phase shift between interferograms or to keep the phase shift between interferograms constant. The present invention provides a simple, inexpensive means to shutter each independent beam of the interferometer in order to facilitate the data acquisition requirements for optical interferometry and phase shifting interferometry. By eliminating the requirement to know the phase shift between interferograms or to keep the phase shift constant, a simple, economical means and apparatus for performing the technique of phase shifting interferometry is provide which, by thermally expanding a fiber optical cable changes the optical path distance of one incident beam relative to another.

  13. Development of Low Parasitic Light Sensitivity and Low Dark Current 2.8 μm Global Shutter Pixel †

    PubMed Central

    Yokoyama, Toshifumi; Tsutsui, Masafumi; Suzuki, Masakatsu; Nishi, Yoshiaki; Mizuno, Ikuo; Lahav, Assaf

    2018-01-01

    We developed a low parasitic light sensitivity (PLS) and low dark current 2.8 μm global shutter pixel. We propose a new inner lens design concept to realize both low PLS and high quantum efficiency (QE). 1/PLS is 7700 and QE is 62% at a wavelength of 530 nm. We also propose a new storage-gate based memory node for low dark current. P-type implants and negative gate biasing are introduced to suppress dark current at the surface of the memory node. This memory node structure shows the world smallest dark current of 9.5 e−/s at 60 °C. PMID:29370146

  14. Development of Low Parasitic Light Sensitivity and Low Dark Current 2.8 μm Global Shutter Pixel.

    PubMed

    Yokoyama, Toshifumi; Tsutsui, Masafumi; Suzuki, Masakatsu; Nishi, Yoshiaki; Mizuno, Ikuo; Lahav, Assaf

    2018-01-25

    Abstract : We developed a low parasitic light sensitivity (PLS) and low dark current 2.8 μm global shutter pixel. We propose a new inner lens design concept to realize both low PLS and high quantum efficiency (QE). 1/PLS is 7700 and QE is 62% at a wavelength of 530 nm. We also propose a new storage-gate based memory node for low dark current. P-type implants and negative gate biasing are introduced to suppress dark current at the surface of the memory node. This memory node structure shows the world smallest dark current of 9.5 e - /s at 60 °C.

  15. Inexpensive driver for stereo videogame glasses

    NASA Astrophysics Data System (ADS)

    Pique, Michael; Coogan, Anthony

    1990-09-01

    We have adapted home videogame glasses from Sega as workstation stereo viewers. A small (4x7x9 cm.) box of electronics receives sync signals in parallel with the monitor (either separate ROB-Sync or composite video) and drives the glasses.The view is dimmer than with costlier shutters, there is more ghosting, and the user is feuered by the wires. But the glasses are so much cheaper than the full-screen shutters (250 instead of about 10 000) that it is practical to provide the benefits of stereo to many more workstation users. We are using them with Sun TAAC-1 workstations; the interlaced video can also be recorded on ordinary NTSC videotape and played on television monitors.

  16. Large area and low power dielectrowetting optical shutter with local deterministic fluid film breakup

    NASA Astrophysics Data System (ADS)

    Zhao, R.; Cumby, B.; Russell, A.; Heikenfeld, J.

    2013-11-01

    A large area (>10 cm2) and low-power (0.1-10 Hz AC voltage, ˜10's μW/cm2) dielectrowetting optical shutter requiring no pixelation is demonstrated. The device consists of 40 μm interdigitated electrodes covered by fluid splitting features and a hydrophobic fluoropolymer. When voltage is removed, the fluid splitting features initiate breakup of the fluid film into small droplets resulting in ˜80% transmission. Both the dielectrowetting and fluid splitting follow theory, allowing prediction of alternate designs and further improved performance. Advantages include scalability, optical polarization independence, high contrast ratio, fast response, and simple construction, which could be of use in switchable windows or transparent digital signage.

  17. The BepiColombo SERENA/ELENA sensor. Approaching final delivery: sensor description and recent results

    NASA Astrophysics Data System (ADS)

    Orsini, S.; Selci, S.; Di Lellis, A. M.; Mura, A.; De Angelis, E.; Milillo, A.; Leoni, R.; Dandouras, I.; Scheer, J.; Wurz, P.

    2012-04-01

    The neutral sensor ELENA (Emitted Low-Energy Neutral Atoms) for the ESA cornerstone BepiColombo mission to Mercury (in the SERENA instrument package) is a new kind of low energetic neutral atoms instrument, mostly devoted to sputtering emission from planetary surfaces, from E ~20 eV up to E~5 keV, within 1-D (4.5°x76°). ELENA is a Time-of-Flight (TOF) system, based on oscillating shutter (operated at frequencies up to 50 kHz) and mechanical gratings: the incoming neutral particles directly impinge upon the entrance with a definite timing (START) and arrive to a STOP detector after a flight path. In this way the low-energy neutral particles are directly detected, without using elements of interaction. The new results of the development of the BepiColombo SERENA/ELENA instrument are presented in the frame of the scientific items (instrument simulations, laboratory testing, etc.). In particular, the actual status of the ELENA TOF sections (shuttering system and MCPs) are reported in the light of recent testing results. The sensor performances are investigated, as well as their capability to accomplish the scientific requirements (new deflector system, shuttering functionality test, MCP efficiency, piezo driver and proximity boards, etc.).

  18. DLP™-based dichoptic vision test system

    NASA Astrophysics Data System (ADS)

    Woods, Russell L.; Apfelbaum, Henry L.; Peli, Eli

    2010-01-01

    It can be useful to present a different image to each of the two eyes while they cooperatively view the world. Such dichoptic presentation can occur in investigations of stereoscopic and binocular vision (e.g., strabismus, amblyopia) and vision rehabilitation in clinical and research settings. Various techniques have been used to construct dichoptic displays. The most common and most flexible modern technique uses liquid-crystal (LC) shutters. When used in combination with cathode ray tube (CRT) displays, there is often leakage of light from the image intended for one eye into the view of the other eye. Such interocular crosstalk is 14% even in our state of the art CRT-based dichoptic system. While such crosstalk may have minimal impact on stereo movie or video game experiences, it can defeat clinical and research investigations. We use micromirror digital light processing (DLP™) technology to create a novel dichoptic visual display system with substantially lower interocular crosstalk (0.3% remaining crosstalk comes from the LC shutters). The DLP system normally uses a color wheel to display color images. Our approach is to disable the color wheel, synchronize the display directly to the computer's sync signal, allocate each of the three (former) color presentations to one or both eyes, and open and close the LC shutters in synchrony with those color events.

  19. Programmable 2-D Addressable Cryogenic Aperture Masks

    NASA Technical Reports Server (NTRS)

    Kutyrev, A. S.; Moseley, S. H.; Jhabvala, M.; Li, M.; Schwinger, D. S.; Silverberg, R. F.; Wesenberg, R. P.

    2004-01-01

    We are developing a two-dimensional array of square microshutters (programmable aperture mask) for a multi-object spectrometer for the James Webb Space Telescope (JWST). This device will provide random access selection of the areas in the field to be studied. The device is in essence a close packed array of square slits, each of which can be opened independently to select areas of the sky for detailed study.The device is produced using a 100-micron thick silicon wafer as a substrate with 0.5-micron thick silicon nitride shutters on top of it. Silicon nitride has been selected as the blade and flexure material because its stiffness allows thinner and lighter structures than single crystal Si, the chief alternative, and because of its ease of manufacture. The 100 micron silicon wafer is backetched in a high aspect ratio Deep Reactive Ion Etching (Deep RIE) to leave only a support grid for the shutters and the address electronics. The shutter actuation is done magnetically whereas addressing is electrostatic. 128x128 format microshutter arrays have been produced. Their operation has been demostarted on 32x32 subarrays. Good reliability of the fabrication process and good quality of the microshutters has been achieved. The mechanical behavior and optical performance of the fabricated arrays at cryogenic temperature are being studied.

  20. Electrophysiological measurement of interest during walking in a simulated environment.

    PubMed

    Takeda, Yuji; Okuma, Takashi; Kimura, Motohiro; Kurata, Takeshi; Takenaka, Takeshi; Iwaki, Sunao

    2014-09-01

    A reliable neuroscientific technique for objectively estimating the degree of interest in a real environment is currently required in the research fields of neuroergonomics and neuroeconomics. Toward the development of such a technique, the present study explored electrophysiological measures that reflect an observer's interest in a nearly-real visual environment. Participants were asked to walk through a simulated shopping mall and the attractiveness of the shopping mall was manipulated by opening and closing the shutters of stores. During the walking task, participants were exposed to task-irrelevant auditory probes (two-stimulus oddball sequence). The results showed a smaller P2/early P3a component of task-irrelevant auditory event-related potentials and a larger lambda response of eye-fixation-related potentials in an interesting environment (i.e., open-shutter condition) than in a boring environment (i.e., closed-shutter condition); these findings can be reasonably explained by supposing that participants allocated more attentional resources to visual information in an interesting environment than in a boring environment, and thus residual attentional resources that could be allocated to task-irrelevant auditory probes were reduced. The P2/early P3a component and the lambda response may be useful measures of interest in a real visual environment. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Next-Generation Microshutter Arrays for Large-Format Imaging and Spectroscopy

    NASA Technical Reports Server (NTRS)

    Moseley, Samuel; Kutyrev, Alexander; Brown, Ari; Li, Mary

    2012-01-01

    A next-generation microshutter array, LArge Microshutter Array (LAMA), was developed as a multi-object field selector. LAMA consists of small-scaled microshutter arrays that can be combined to form large-scale microshutter array mosaics. Microshutter actuation is accomplished via electrostatic attraction between the shutter and a counter electrode, and 2D addressing can be accomplished by applying an electrostatic potential between a row of shutters and a column, orthogonal to the row, of counter electrodes. Microelectromechanical system (MEMS) technology is used to fabricate the microshutter arrays. The main feature of the microshutter device is to use a set of standard surface micromachining processes for device fabrication. Electrostatic actuation is used to eliminate the need for macromechanical magnet actuating components. A simplified electrostatic actuation with no macro components (e.g. moving magnets) required for actuation and latching of the shutters will make the microshutter arrays robust and less prone to mechanical failure. Smaller-size individual arrays will help to increase the yield and thus reduce the cost and improve robustness of the fabrication process. Reducing the size of the individual shutter array to about one square inch and building the large-scale mosaics by tiling these smaller-size arrays would further help to reduce the cost of the device due to the higher yield of smaller devices. The LAMA development is based on prior experience acquired while developing microshutter arrays for the James Webb Space Telescope (JWST), but it will have different features. The LAMA modular design permits large-format mosaicking to cover a field of view at least 50 times larger than JWST MSA. The LAMA electrostatic, instead of magnetic, actuation enables operation cycles at least 100 times faster and a mass significantly smaller compared to JWST MSA. Also, standard surface micromachining technology will simplify the fabrication process, increasing yield and reducing cost.

  2. Functional morphology of the luminescence system of Siphamia versicolor (Perciformes: Apogonidae), a bacterially luminous coral reef fish.

    PubMed

    Dunlap, Paul V; Nakamura, Masaru

    2011-08-01

    Previous studies of the luminescence system of Siphamia versicolor (Perciformes: Apogonidae) identified a ventral light organ, reflector, lens, duct, and a ventral diffuser extending from the throat to the caudal peduncle. The control and function of luminescence in this and other species of Siphamia, however, have not been defined. Morphological examination of fresh and preserved specimens identified additional components of the luminescence system involved in control and ventral emission of luminescence, including a retractable shutter over the ventral face of the light organ, contiguity of the ventral diffuser from the caudal peduncle to near the chin, and transparency of the bones and other tissues of the lower jaw. The shutter halves retract laterally, allowing the ventral release of light, and relax medially, blocking ventral light emission; topical application of norepinephrine to the exposed light organ resulted in retraction of the shutter halves, which suggests that operation of the shutter is under neuromuscular control. The extension of the diffuser to near the chin and transparency of the lower jaw allow a uniform emission of luminescence over the entire ventrum of the fish. The live aquarium-held fish were found to readily and consistently display ventral luminescence. At twilight, the fish left the protective association with their longspine sea urchin, Diadema setosum, and began to emit ventral luminescence and to feed on zooplankton. Ventral luminescence illuminated a zone below and around the fish, which typically swam close to the substrate. Shortly after complete darkness, the fish stopped feeding and emitting luminescence. These observations suggest that S. versicolor uses ventral luminescence to attract and feed on zooplankton from the reef benthos at twilight. Ventral luminescence may allow S. versicolor to exploit for feeding the gap at twilight in the presence of potential predators as the reef transitions from diurnally active to nocturnally active organisms. Copyright © 2011 Wiley-Liss, Inc.

  3. Effect of pulsed electric field on the proteolysis of cold boned beef M. Longissimus lumborum and M. Semimembranosus.

    PubMed

    Suwandy, Via; Carne, Alan; van de Ven, Remy; Bekhit, Alaa El-Din A; Hopkins, David L

    2015-02-01

    The effects of pulsed electric field (PEF) and ageing (3, 7, 14 and 21 days) on the shear force, protein profile, and post-mortem proteolysis of beef loins (M. Longissimus lumborum, LL) and topsides (M. Semimembranosus, SM) were investigated using a range of pulsed electric field treatments [voltages (5 and 10 kV) and frequencies (20, 50, and 90 Hz)]. PEF treatment decreased the shear force of beef LL and SM muscles by up to 19%. The reduction in the shear force in the LL was not affected by the treatment intensity whereas the reduction in the SM was dependent on PEF frequency. PEF treated beef loins showed increased proteolysis, both early post-mortem and during subsequent post-mortem storage reflected by increased degradation of troponin-T and desmin. The most prominent troponin-T degradation was found in samples treated with 5 kV-90 Hz, 10 kV-20 Hz at day 3 and day 7 post-treatment in addition to 10 kV-50 Hz in subsequent post-treatment times. The degradation of desmin in PEF treated beef loins increased with ageing time.

  4. Pulse oximeter accuracy and precision at five different sensor locations in infants and children with cyanotic heart disease

    PubMed Central

    Das, Jyotirmoy; Aggarwal, Amit; Aggarwal, Naresh Kumar

    2010-01-01

    Since the invention of pulse oximetry by Takuo Aoyagi in the early 1970s, its use has expanded beyond the perioperative care into neonatal, paediatric and adult intensive care units (ICUs). Pulse oximetry is one of the most important advances in respiratory monitoring as its readings (SpO2) are used clinically as an indirect estimation of arterial oxygen saturation (SaO2). Sensors were placed frequently on the sole, palm, ear lobe or toes in addition to finger. On performing an extensive Medline search using the terms “accuracy of pulse oximetry” and “precision of pulse oximetry”, limited data were found in congenital heart disease patients in the immediate post-corrective stage. Also, there are no reports and comparative data of the reliability and precision of pulse oximetry when readings from five different sensor locations (viz. finger, palm, toe, sole and ear) are analysed simultaneously. To fill these lacunae of knowledge, we undertook the present study in 50 infants and children with cyanotic heart disease in the immediate post-corrective stage. PMID:21224970

  5. Pulse oximeter accuracy and precision at five different sensor locations in infants and children with cyanotic heart disease.

    PubMed

    Das, Jyotirmoy; Aggarwal, Amit; Aggarwal, Naresh Kumar

    2010-11-01

    Since the invention of pulse oximetry by Takuo Aoyagi in the early 1970s, its use has expanded beyond the perioperative care into neonatal, paediatric and adult intensive care units (ICUs). Pulse oximetry is one of the most important advances in respiratory monitoring as its readings (SpO(2)) are used clinically as an indirect estimation of arterial oxygen saturation (SaO(2)). Sensors were placed frequently on the sole, palm, ear lobe or toes in addition to finger. On performing an extensive Medline search using the terms "accuracy of pulse oximetry" and "precision of pulse oximetry", limited data were found in congenital heart disease patients in the immediate post-corrective stage. Also, there are no reports and comparative data of the reliability and precision of pulse oximetry when readings from five different sensor locations (viz. finger, palm, toe, sole and ear) are analysed simultaneously. To fill these lacunae of knowledge, we undertook the present study in 50 infants and children with cyanotic heart disease in the immediate post-corrective stage.

  6. Response of transpiration to rain pulses for two tree species in a semiarid plantation.

    PubMed

    Chen, Lixin; Zhang, Zhiqiang; Zeppel, Melanie; Liu, Caifeng; Guo, Junting; Zhu, Jinzhao; Zhang, Xuepei; Zhang, Jianjun; Zha, Tonggang

    2014-09-01

    Responses of transpiration (Ec) to rain pulses are presented for two semiarid tree species in a stand of Pinus tabulaeformis and Robinia pseudoacacia. Our objectives are to investigate (1) the environmental control over the stand transpiration after rainfall by analyzing the effect of vapor pressure deficit (VPD), soil water condition, and rainfall on the post-rainfall Ec development and recovery rate, and (2) the species responses to rain pulses and implications on vegetation coverage under a changing rainfall regime. Results showed that the sensitivity of canopy conductance (Gc) to VPD varied under different incident radiation and soil water conditions, and the two species exhibited the same hydraulic control (-dG c/dlnVPD to Gcref ratio) over transpiration. Strengthened physiological control and low sapwood area of the stand contributed to low Ec. VPD after rainfall significantly influenced the magnitude and time series of post-rainfall stand Ec. The fluctuation of post-rainfall VPD in comparison with the pre-rainfall influenced the Ec recovery. Further, the stand Ec was significantly related to monthly rainfall, but the recovery was independent of the rainfall event size. Ec enhanced with cumulative soil moisture change (ΔVWC) within each dry-wet cycle, yet still was limited in large rainfall months. The two species had different response patterns of post-rainfall Ec recovery. Ec recovery of P. tabulaeformis was influenced by the pre- and post-rainfall VPD differences and the duration of rainless interval. R. pseudoacacia showed a larger immediate post-rainfall Ec increase than P. tabulaeformis did. We, therefore, concluded that concentrated rainfall events do not trigger significant increase of transpiration unless large events penetrate the deep soil and the species differences of Ec in response to pulses of rain may shape the composition of semiarid woodlands under future rainfall regimes.

  7. Conceptual phase A design of a cryogenic shutter mechanism for the SAFARI flight instrument

    NASA Astrophysics Data System (ADS)

    Eigenmann, Max; Wehmeier, Udo J.; Vuilleumier, Aurèle; Messina, Gabriele; Meyer, Michael R.

    2012-09-01

    We present a conceptual design for a cryogenic optical mechanism for the SAFARI instrument. SAFARI is a long wavelength (34-210 micron) Imaging Fourier Transform Spectrometer (FTS) to fly as an ESA instrument on the JAXA SPICA mission projected to launch in 2021. SPICA is a large 3m class space telescope which will have an operating temperature of less than 7K. The SAFARI shutter is a single point of failure flight mechanism designed to operate in space at a temperature of 4K which meets redundancy and reliability requirements of this challenging mission. The conceptual design is part of a phase A study led by ETH Institute for Astronomy and conducted by RUAG Space AG.

  8. Implementation and performance of shutterless uncooled micro-bolometer cameras

    NASA Astrophysics Data System (ADS)

    Das, J.; de Gaspari, D.; Cornet, P.; Deroo, P.; Vermeiren, J.; Merken, P.

    2015-06-01

    A shutterless algorithm is implemented into the Xenics LWIR thermal cameras and modules. Based on a calibration set and a global temperature coefficient the optimal non-uniformity correction is calculated onboard of the camera. The limited resources in the camera require a compact algorithm, hence the efficiency of the coding is important. The performance of the shutterless algorithm is studied by a comparison of the residual non-uniformity (RNU) and signal-to-noise ratio (SNR) between the shutterless and shuttered correction algorithm. From this comparison we conclude that the shutterless correction is only slightly less performant compared to the standard shuttered algorithm, making this algorithm very interesting for thermal infrared applications where small weight and size, and continuous operation are important.

  9. How to align a new detector and micro shutter inside JWST's Near Infrared Spectrograph (NIRSpec)

    NASA Astrophysics Data System (ADS)

    te Plate, Maurice; Rumler, Peter; Jensen, Peter; Eder, Robert; Ehrenwinkler, Ralf; Merkle, Frank; Roedel, Andreas; Speckmaier, Max; Johnson, Thomas E.; Mott, Brent; Snodgrass, Stephen; Gunn, Chris; Ward, Justin

    2016-09-01

    JWST will be the biggest space telescope ever built and it will lead to astounding scientific breakthroughs. The mission will be launched in October 2018 from Kourou, French Guyana by an ESA provided Ariane 5 rocket. NIRSpec, one of the four instruments on board of the mission, recently underwent a major upgrade. New infrared detectors were installed and the Micro Shutter Assembly (MSA) was replaced as well. The rework was necessary because both systems were found to be degrading beyond a level that could be accepted. The installation and "in situ" alignment of these new systems required special techniques and alignment jigs that will be described in this paper. Some first results will be presented as well.

  10. Quantum-shutter approach to tunneling time scales with wave packets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamada, Norifumi; Garcia-Calderon, Gaston; Villavicencio, Jorge

    2005-07-15

    The quantum-shutter approach to tunneling time scales [G. Garcia-Calderon and A. Rubio, Phys. Rev. A 55, 3361 (1997)], which uses a cutoff plane wave as the initial condition, is extended to consider certain type of wave packet initial conditions. An analytical expression for the time-evolved wave function is derived. The time-domain resonance, the peaked structure of the probability density (as the function of time) at the exit of the barrier, originally found with the cutoff plane wave initial condition, is studied with the wave packet initial conditions. It is found that the time-domain resonance is not very sensitive to themore » width of the packet when the transmission process occurs in the tunneling regime.« less

  11. The NACA High-Speed Motion-Picture Camera Optical Compensation at 40,000 Photographs Per Second

    NASA Technical Reports Server (NTRS)

    Miller, Cearcy D

    1946-01-01

    The principle of operation of the NACA high-speed camera is completely explained. This camera, operating at the rate of 40,000 photographs per second, took the photographs presented in numerous NACA reports concerning combustion, preignition, and knock in the spark-ignition engine. Many design details are presented and discussed, details of an entirely conventional nature are omitted. The inherent aberrations of the camera are discussed and partly evaluated. The focal-plane-shutter effect of the camera is explained. Photographs of the camera are presented. Some high-speed motion pictures of familiar objects -- photoflash bulb, firecrackers, camera shutter -- are reproduced as an illustration of the quality of the photographs taken by the camera.

  12. Primary investigations on the potential of a novel diode pumped Er:YAG laser system for bone surgery

    NASA Astrophysics Data System (ADS)

    Stock, Karl; Diebolder, Rolf; Hausladen, Florian; Wurm, Holger; Lorenz, Swetlana; Hibst, Raimund

    2013-03-01

    Flashlamp pumped Er:YAG-lasers are successfully clinically used for both precise soft and hard tissue ablation. As an alternative, actually a novel diode pumped Er:YAG laser system (Pantec Engineering AG) becomes available, with mean laser power up to 15W and pulse repetition rate up to 1kHz. The aim of the presented study is to investigate the effect of this laser system on bone tissue at various irradiation parameters, particular at repetition rates exceeding 100 Hz. For reproducible experiments, firstly an appropriate experimental set-up was realized with a beam delivery and focusing unit, a computer controlled stepper unit with sample holder, and a shutter unit. It allowed to move the sample (1mm- 3mm sawed slices of pig bone) with a defined velocity while irradiation by various laser parameters. A water spray served to moisten the sample surfaces. After irradiation the grooves were analyzed by light microscopy and laser scanning microscopy regarding to the ablation quality, the groove geometry, the ablation efficacy, and the thermal effects. The resulting grooves are slightly cone shaped (groove depth up to 3mm, width about 200μm) with sharp edges at the surface. At 1W, 200Hz, 5mm/s sample movement and with water irrigation the measured ablation speed Δz/Δt is 10.8 mm/s. The ablation depth per pulse is 54μm. In conclusion, these first experiments demonstrate that the diode pumped Er:YAG laser system is an efficient tool for use in bone surgery.

  13. Muonic molecular ions p p μ and p d μ driven by superintense VUV laser pulses: Postexcitation muonic and nuclear oscillations and high-order harmonic generation

    NASA Astrophysics Data System (ADS)

    Paramonov, Guennaddi K.; Saalfrank, Peter

    2018-05-01

    The non-Born-Oppenheimer quantum dynamics of p p μ and p d μ molecular ions excited by ultrashort, superintense VUV laser pulses polarized along the molecular axis (z ) is studied by the numerical solution of the time-dependent Schrödinger equation within a three-dimensional (3D) model, including the internuclear distance R and muon coordinates z and ρ , a transversal degree of freedom. It is shown that in both p p μ and p d μ , muons approximately follow the applied laser field out of phase. After the end of the laser pulse, expectation values , <ρ > , and demonstrate "post-laser-pulse" oscillations in both p p μ and p d μ . In the case of p d μ , the post-laser-pulse oscillations of and appear as shaped "echo pulses." Power spectra, which are related to high-order harmonic generation (HHG), generated due to muonic and nuclear motion are calculated in the acceleration form. For p d μ it is found that there exists a unique characteristic frequency ωoscp d μ representing both frequencies of post-laser-pulse muonic oscillations and the frequency of nuclear vibrations, which manifest themselves by very sharp maxima in the corresponding power spectra of p d μ . The homonuclear p p μ ion does not possess such a unique characteristic frequency. The "exact" dynamics and power, and HHG spectra of the 3D model are compared with a Born-Oppenheimer, fixed-nuclei model featuring interesting differences: postpulse oscillations are absent and HHG spectra are affected indirectly or directly by nuclear motion.

  14. Temporal and spectral properties of the songs of the southern green stink bug Nezara viridula (L.) from Slovenia.

    PubMed

    Cokl, A; Virant-Doberlet, M; Stritih, N

    2000-01-01

    Substrate born songs of the southern green stinkbug Nezara viridula (L.) from Slovenia were recorded and analysed. The male calling song is composed of narrow-band regularly repeated single pulses and of broad-band frequency modulated pulses grouped into pulse trains. The female calling song is characterised by broad-band pulsed and narrow-band non-pulsed pulse trains. A frequency modulated pre-pulse precedes the narrow-band pulse train. A frequency-modulated post-pulse usually follows the pulse train of the male courtship song. The male calling song triggers broad-band pulse trains of the female courtship song. The female also produces a repelling low-frequency vibration that inhibits male calling and courtship. The male rival song is characterised by prolonged pulses with a typical frequency modulation.

  15. High-speed electromechanical shutter for imaging spectrographs

    NASA Technical Reports Server (NTRS)

    Nguyen, Quang-Viet (Inventor)

    2005-01-01

    The present invention presents a high-speed electromechanical shutter which has at least two rotary beam choppers that are synchronized using a phase-locked loop electronic control to reduce the duty cycle. These choppers have blade means that can comprise discs or drums, each having about 60 (+/-15) slots which are from about 0.3 to about 0.8 mm wide and about 5 to about 20 mm long (radially) which are evenly distributed through out 360?, and a third rotary chopper which is optically aligned has a small number of slots, such as for example, 1 to 10 slots which are about 1 to about 2 mm wide and about 5 to about 20 mm long (radially). Further the blade means include phase slots that allow the blade means to be phase locked using a closed loop control circuit. In addition, in a preferred embodiment, the system also has a leaf shutter. Thus the invention preferably achieves a gate width of less than about 100 microseconds, using motors that operate at 3000 to 10,000 rpm, and with a phase jitter of less than about 1.5 microseconds, and further using an aperture with more than about 75% optical transmission with a clear aperture of about 0.8 mm?10 mm. The system can be synchronized to external sources at 0 6 kHz lasers, data acquisition systems, and cameras.

  16. Methods of dark signal determination for CCD array spectroradiometers used in solar UVR measurements.

    PubMed

    Baczynska, K A; Khazova, M

    2015-02-01

    The methods of the dark signal determination by direct contemporaneous measurements using a light spectrum and modelling of the dark signal based on the dark signal characterisation data were discussed. These techniques were tested with two charge-couple detectors (CCD) array spectroradiometers used in solar UVR measurements. The sensitivity of both instruments was significantly reduced when shutters were used; the measured signal varied by up to 12% depending on the orientation of the shutter. The shutters should be permanently attached to the SSR, so that the orientation cannot be changed to prevent an increase in uncertainty. The method of using blind pixels from the optically inactive part of the CCD array in a light spectrum could be used to derive the dark signal with some limitations for integration times <10 s for the QE65000. An alternative method of deriving the dark signal from light measurements using out-of-range pixels has been proved impossible due to out-of-range stray light in both instruments. The dark signal was characterised for the range of integration times and ambient temperatures of 15-35°C. Based on these data, the model of the dark signal was developed so that a single value of the dark signal can be subtracted over the whole spectral range if the instrument temperature is known. © Crown copyright 2014.

  17. Enceladus Up-Close

    NASA Image and Video Library

    2015-10-30

    During its closest ever dive past the active south polar region of Saturn moon Enceladus, NASA Cassini spacecraft quickly shuttered its imaging cameras to capture glimpses of the fast moving terrain below.

  18. 03pd0676

    NASA Image and Video Library

    2003-03-07

    File name :DSC_0749.JPG File size :1.1MB(1174690Bytes) Date taken :2003/03/07 13:51:29 Image size :2000 x 1312 Resolution :300 x 300 dpi Number of bits :8bit/channel Protection attribute :Off Hide Attribute :Off Camera ID :N/A Camera :NIKON D1H Quality mode :FINE Metering mode :Matrix Exposure mode :Shutter priority Speed light :No Focal length :20 mm Shutter speed :1/500second Aperture :F11.0 Exposure compensation :0 EV White Balance :Auto Lens :20 mm F 2.8 Flash sync mode :N/A Exposure difference :0.0 EV Flexible program :No Sensitivity :ISO200 Sharpening :Normal Image Type :Color Color Mode :Mode II(Adobe RGB) Hue adjustment :3 Saturation Control :N/A Tone compensation :Normal Latitude(GPS) :N/A Longitude(GPS) :N/A Altitude(GPS) :N/A

  19. A math model for high velocity sensoring with a focal plane shuttered camera.

    NASA Technical Reports Server (NTRS)

    Morgan, P.

    1971-01-01

    A new mathematical model is presented which describes the image produced by a focal plane shutter-equipped camera. The model is based upon the well-known collinearity condition equations and incorporates both the translational and rotational motion of the camera during the exposure interval. The first differentials of the model with respect to exposure interval, delta t, yield the general matrix expressions for image velocities which may be simplified to known cases. The exposure interval, delta t, may be replaced under certain circumstances with a function incorporating blind velocity and image position if desired. The model is tested using simulated Lunar Orbiter data and found to be computationally stable as well as providing excellent results, provided that some external information is available on the velocity parameters.

  20. 03pd0517

    NASA Image and Video Library

    2002-02-19

    File name :DSC_0028.JPG File size :2.8MB(2950833Bytes) Date taken :2002/02/19 09:49:01 Image size :3008 x 2000 Resolution :300 x 300 dpi Number of bits :8bit/channel Protection attribute :Off Hide Attribute :Off Camera ID :N/A Camera :NIKON D100 Quality mode :N/A Metering mode :Matrix Exposure mode :Shutter priority Speed light :Yes Focal length :24 mm Shutter speed :1/60second Aperture :F3.5 Exposure compensation :0 EV White Balance :N/A Lens :N/A Flash sync mode :N/A Exposure difference :N/A Flexible program :N/A Sensitivity :N/A Sharpening :N/A Image Type :Color Color Mode :N/A Hue adjustment :N/A Saturation Control :N/A Tone compensation :N/A Latitude(GPS) :N/A Longitude(GPS) :N/A Altitude(GPS) :N/A

  1. 03pd0535

    NASA Image and Video Library

    2002-02-24

    File name :DSC_0047.JPG File size :2.8MB(2931574Bytes) Date taken :2002/02/24 10:06:57 Image size :3008 x 2000 Resolution :300 x 300 dpi Number of bits :8bit/channel Protection attribute :Off Hide Attribute :Off Camera ID :N/A Camera :NIKON D100 Quality mode :N/A Metering mode :Matrix Exposure mode :Shutter priority Speed light :Yes Focal length :24 mm Shutter speed :1/180second Aperture :F20.0 Exposure compensation :+0.3 EV White Balance :N/A Lens :N/A Flash sync mode :N/A Exposure difference :N/A Flexible program :N/A Sensitivity :N/A Sharpening :N/A Image Type :Color Color Mode :N/A Hue adjustment :N/A Saturation Control :N/A Tone compensation :N/A Latitude(GPS) :N/A Longitude(GPS) :N/A Altitude(GPS) :N/A

  2. Picosecond laser system with 30-W average power via cavity dumping and amplifying

    NASA Astrophysics Data System (ADS)

    Fu, J.; Pang, Q. S.; Chang, L.; Bai, Z. A.; Ai, Q. K.; Chen, L. Y.; Chen, M.; Li, G.; Ma, Y. F.; Fan, Z. W.; Niu, G.; Yu, J.; Liu, Y.; Zhang, X.; Kang, W. Y.; He, K.

    2011-06-01

    We present a picosecond laser system with high energy by technologies of cavity dumping and amplifying. Firstly, pulses with 10 ps and ˜520 nJ were obtained by cavity-dumped mode-locked laser at 10 kHz repetition rate. Secondly those pulses were seeded into a side-pumped regenerative amplifier (RA). Then pulses output from the regenerative amplifier were amplified by two four-pass post amplifiers. From the laser system pulses with an average power of 30 W corresponding to 3 mJ pulse energy were achieved with the pulse-width of 25.4 ps at repetition rate of 10 kHz.

  3. New, high-efficiency ion trap mobility detection system for narcotics and explosives

    NASA Astrophysics Data System (ADS)

    McGann, William J.; Bradley, V.; Borsody, A.; Lepine, S.

    1994-10-01

    A new patented Ion Trap Mobility Spectrometer (ITMS) design is presented. Conventional IMS designs typically operate below 0.1% efficiency. This is due primarily to electric field driven, sample ion discharge on a shutter grid. Since 99.9% of the sample ions generated in the reaction region are lost in this discharge process, the sensitivity of conventional systems is limited. The new design provides greater detection efficiency than conventional designs through the use of an `ion trap' concept. The paper describes the plasma and sample ion dynamics in the reaction region of the new detector and discusses the advantages of utilizing a `field-free' space to generate sample ions with high efficiency. Fast electronic switching is described which is used to perturb the field-free space and pulse the sample ions into the drift region for separation and subsequent detection using pseudo real-time software for analysis and display of the data. Many applications for this new detector are now being considered including the detection of narcotics and explosives. Preliminary ion spectra, reduced mobility data and sensitivity data are presented for fifteen narcotics, including cocaine, THC and LSD are reported.

  4. New high-efficiency ion-trap mobility detection system for narcotics

    NASA Astrophysics Data System (ADS)

    McGann, William J.

    1997-02-01

    A new patented Ion Trap Mobility Spectrometer design is presented. Conventional IMS designs typically operate below 0.1 percent efficiency. This is due primarily to electric field driven, sample ion discharge on a shutter grid. Since 99.9 percent of the sample ions generated in the reaction region are lost int his discharge process, the sensitivity of conventional systems is limited. The new design provides greater detection efficiency than conventional designs through the use of an 'ion trap' concept. The paper describes the plasma and sample ion dynamics in the reaction region of the new detector and discusses the advantages of utilizing a 'field-free' space to generate sample ions with high efficiency. Fast electronic switching is described which is used to perturb the field-free space and pulse the sample ions into the drift region for separation and subsequent detection using pseudo real-time software for analysis and display of the data. One application for this new detector is now being developed, a portable, hand-held system with switching capability for the detection of drugs and explosives. Preliminary ion spectra and sensitivity data are presented for cocaine and heroin using a hand sniffer configuration.

  5. New high-efficiency ion trap mobility detection system for narcotics and explosives

    NASA Astrophysics Data System (ADS)

    McGann, William J.; Jenkins, Anthony; Ribiero, K.; Napoli, J.

    1994-03-01

    A new patented ion trap mobility spectrometer design is presented. Conventional IMS designs typically operate below 0.1% efficiency. This is due primarily to electrical-field-driven, sample ion discharge on a shutter grid. Since 99.9% of the sample ions generated in the reaction region are lost in this discharge process, the sensitivity of conventional systems is limited. The new design provides greater detection efficiency than conventional designs through the use of an `ion trap' concept. The paper describes the plasma and sample ion dynamics in the reaction region of the new detector and discusses the advantages of utilizing a `field-free' space to generate sample ions with high efficiency. Fast electronic switching is described which is used to perturb the field-free space and pulse the sample ions into the drift region for separation and subsequent detection using pseudo real-time software for analysis and display of the data. Many applications for this new detector are now being considered including the detection of narcotics and explosives. Preliminary ion spectra, reduced mobility data and sensitivity data are presented for fifteen narcotics, including cocaine, THC, and LSD are reported.

  6. Optoelectronic stereoscopic device for diagnostics, treatment, and developing of binocular vision

    NASA Astrophysics Data System (ADS)

    Pautova, Larisa; Elkhov, Victor A.; Ovechkis, Yuri N.

    2003-08-01

    Operation of the device is based on alternative generation of pictures for left and right eyes on the monitor screen. Controller gives pulses on LCG so that shutter for left or right eye opens synchronously with pictures. The device provides frequency of switching more than 100 Hz, and that is why the flickering is absent. Thus, a separate demonstration of images to the left eye or to the right one in turn is obtained for patients being unaware and creates the conditions of binocular perception clsoe to natural ones without any additional separation of vision fields. LC-cell transfer characteristic coodination with time parameters of monitor screen has enabled to improve stereo image quality. Complicated problem of computer stereo images with LC-glasses is so called 'ghosts' - noise images that come to blocked eye. We reduced its influence by adapting stereo images to phosphor and LC-cells characteristics. The device is intended for diagnostics and treatment of stabismus, amblyopia and other binocular and stereoscopic vision impairments, for cultivating, training and developing of stereoscopic vision, for measurements of horizontal and vertical phoria, phusion reserves, the stereovision acuity and some else, for fixing central scotoma borders, as well as suppression scotoma in strabismus too.

  7. Evaluation of the Human/Extreme Environment Interaction: Implications for Enhancing Operational Performance and Recovery

    DTIC Science & Technology

    2014-02-01

    and 4 hours during the recovery using a pulse oximeter (Nonin Onyx II 9550, Plymouth, MN). Analysis Skeletal Muscle RNA isolation. An 8-20...Oximetry. Blood oxygen saturation was evaluated before and after exercise, and during recovery at 0:30, 2:30, 4:30, and 6:00 using a pulse oximeter ...cycling for 45 minutes, post exercise, and every hour during the 6-hour recovery using pulse oximeter (Nonin Onyx Finger Pulse Oximeter , Nonin Medical

  8. Randomized and controlled prospective trials of Ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment for lower back post-herpetic neuralgia.

    PubMed

    Pi, Z B; Lin, H; He, G D; Cai, Z; Xu, X Z

    2015-01-01

    To evaluate the efficacy of ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment for lower back post-herpetic neuralgia. 128 cases of lower back or anterior abdominal wall acute post-herpetic neuralgia patients were selected. They were randomly divided into two groups. Group A: oral treatment only with gabapentin + celecoxib + amitriptyline. Group B: while taking these drugs, patients were treated with radiofrequency (RF) pulses using a portable ultrasound device using the paravertebral puncture technique. In both groups, sudden outbreaks of pain were treated with immediate release 10mg morphine tablets. Visual analogue scale (VAS) was used for pain score, Pittsburgh Sleep Quality Index scale (PSQI) was used to evaluate sleep quality and morphine consumption were recorded at different time points, before and after treatment. Treatment efficiency was calculated while the occurrence of complications was documented. At each time point after treatment, VAS scores were lower, but scores in the RF group was significantly lower than those of the oral-only group. In terms of sleep quality scores and morphine consumption between the two groups, the RF group was significantly lower than the oral-only group. During the procedure no error occurred with needle penetrating the abdominal cavity, chest, offal or blood vessels. Ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment of lower back or anterior abdominal wall post-herpetic neuralgia proved effective by reducing morphine use in patients and led to fewer adverse reactions.

  9. Response of transpiration to rain pulses for two tree species in a semiarid plantation

    NASA Astrophysics Data System (ADS)

    Chen, Lixin; Zhang, Zhiqiang; Zeppel, Melanie; Liu, Caifeng; Guo, Junting; Zhu, Jinzhao; Zhang, Xuepei; Zhang, Jianjun; Zha, Tonggang

    2014-09-01

    Responses of transpiration ( E c) to rain pulses are presented for two semiarid tree species in a stand of Pinus tabulaeformis and Robinia pseudoacacia. Our objectives are to investigate (1) the environmental control over the stand transpiration after rainfall by analyzing the effect of vapor pressure deficit (VPD), soil water condition, and rainfall on the post-rainfall E c development and recovery rate, and (2) the species responses to rain pulses and implications on vegetation coverage under a changing rainfall regime. Results showed that the sensitivity of canopy conductance ( G c) to VPD varied under different incident radiation and soil water conditions, and the two species exhibited the same hydraulic control (-d G c/dlnVPD to G cref ratio) over transpiration. Strengthened physiological control and low sapwood area of the stand contributed to low E c. VPD after rainfall significantly influenced the magnitude and time series of post-rainfall stand E c. The fluctuation of post-rainfall VPD in comparison with the pre-rainfall influenced the E c recovery. Further, the stand E c was significantly related to monthly rainfall, but the recovery was independent of the rainfall event size. E c enhanced with cumulative soil moisture change (ΔVWC) within each dry-wet cycle, yet still was limited in large rainfall months. The two species had different response patterns of post-rainfall E c recovery. E c recovery of P. tabulaeformis was influenced by the pre- and post-rainfall VPD differences and the duration of rainless interval. R. pseudoacacia showed a larger immediate post-rainfall E c increase than P. tabulaeformis did. We, therefore, concluded that concentrated rainfall events do not trigger significant increase of transpiration unless large events penetrate the deep soil and the species differences of E c in response to pulses of rain may shape the composition of semiarid woodlands under future rainfall regimes.

  10. Unstable and multiple pulsing can be invisible to ultrashort pulse measurement techniques

    DOE PAGES

    Rhodes, Michelle A.; Guang, Zhe; Trebino, Rick

    2016-12-29

    Here, multiple pulsing occurs in most ultrashort-pulse laser systems when pumped at excessively high powers, and small fluctuations in pump power in certain regimes can cause unusual variations in the temporal separations of sub-pulses. Unfortunately, the ability of modern intensity-and-phase pulse measurement techniques to measure such unstable multi-pulsing has not been studied. Here we report calculations and simulations finding that allowing variations in just the relative phase of a satellite pulse causes the second pulse to completely disappear from a spectral interferometry for direct electric field reconstruction (SPIDER) measurement. We find that, although neither frequency-resolved optical gating (FROG) nor autocorrelationmore » can determine the precise properties of satellite pulses due to the presence of instability, they always succeed in, at least, seeing the satellite pulses. Also, additional post-processing of the measured FROG trace can determine the correct approximate relative height of the satellite pulse and definitively indicate the presence of unstable multiple-pulsing.« less

  11. Unstable and multiple pulsing can be invisible to ultrashort pulse measurement techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rhodes, Michelle A.; Guang, Zhe; Trebino, Rick

    Here, multiple pulsing occurs in most ultrashort-pulse laser systems when pumped at excessively high powers, and small fluctuations in pump power in certain regimes can cause unusual variations in the temporal separations of sub-pulses. Unfortunately, the ability of modern intensity-and-phase pulse measurement techniques to measure such unstable multi-pulsing has not been studied. Here we report calculations and simulations finding that allowing variations in just the relative phase of a satellite pulse causes the second pulse to completely disappear from a spectral interferometry for direct electric field reconstruction (SPIDER) measurement. We find that, although neither frequency-resolved optical gating (FROG) nor autocorrelationmore » can determine the precise properties of satellite pulses due to the presence of instability, they always succeed in, at least, seeing the satellite pulses. Also, additional post-processing of the measured FROG trace can determine the correct approximate relative height of the satellite pulse and definitively indicate the presence of unstable multiple-pulsing.« less

  12. Post-exercise pulse pressure is a better predictor of executive function than pre-exercise pulse pressure in cognitively normal older adults.

    PubMed

    Scott, Bonnie M; Maye, Jacqueline; Jones, Jacob; Thomas, Kelsey; Mangal, Paul C; Trifilio, Erin; Hass, Chris; Marsiske, Michael; Bowers, Dawn

    2016-07-01

    Exercise "stress tests" are widely used to assess cardiovascular function and to detect abnormalities. In line with the view of exercise as a stressor, the present study examined the relationship between cognitive function and cardiovascular activity before and after light physical exercise in a sample of 84 non-demented community-dwelling older adults. Based on known relationships between hypertension, executive function and cerebral white matter changes, we hypothesized that greater post-exercise reactivity, as indexed by higher pulse pressure, would be more related to worse performance on frontal-executive tasks than pre-exercise physiologic measures. All participants were administered a comprehensive neuropsychological battery and underwent a Six Minute Walk Test (6MWT), with blood pressure (BP) measures obtained immediately before and after the walk. Pulse pressure (PP) was derived from BP as an indicator of vascular auto-regulation and composite scores were computed for each cognitive domain assessed. As predicted, worse executive function scores exhibited a stronger relationship with post-exercise PP than pre-exercise PP. Results suggest that PP following system stress in the form of walking may be more reflective of the state of vascular integrity and associated executive dysfunction in older adults than baseline physiologic measures.

  13. Carrier Dynamics and Application of the Phase Coherent Photorefractive Effect in ZnSe Quantum Wells

    NASA Astrophysics Data System (ADS)

    Dongol, Amit

    The intensity dependent diffraction efficiency of a phase coherent photorefractive (PCP) ZnSe quantum well (QW) is investigated at 80 K in a two-beam four-wave mixing (FWM) configuration using 100 fs laser pulses with a repetition rate of 80 MHz. The observed diffraction efficiencies of the first and second-order diffracted beam are on the order of 10-3 and 10-5, respectively, revealing nearly no intensity dependence. The first-order diffraction is caused by the PCP effect where the probe-pulse is diffracted due to a long-living incoherent electron density grating in the QW. The second-order diffraction is created by a combination of diffraction processes. For negative probe-pulse delay, the exciton polarization is diffracted at the electron grating twice by a cascade effect. For positive delay, the diffracted signal is modified by the destructive interference with a chi(5) generated signal due to a dynamical screening effect. Model calculations of the signal traces based on the optical Bloch equations considering inhomogeneous broadening of exciton energies are in good agreement with the experimental data. To study the carrier dynamics responsible for the occurrence of the PCP effect, threebeam FWM experiments are carried out. The non-collinear wave-vectors k1 , k2 and k3 at central wavelength of 441 nm (~2.81 eV) were resonantly tuned to the heavy-hole exciton transition energy at 20 K. In the FWM experiment the time coincident strong pump pulses k1 and k2 create both an exciton density grating in the QW and an electron-hole pair grating in the GaAs while the delayed weak pulse k3 simultaneously probes the exciton lifetime as well as the electron grating capture time. The model calculations are in good agreement with the experimental results also providing information about the transfer delay of electrons arriving from the substrate to the QW. For negative probe-pulse delay we still observe a diffracted signal due to the long living electron density grating in the QW. The electron grating build-up and decay times are also studied with the modified three-beam FWM set-up. Using an optical shutter for pump pulses k1and k2, the dynamics of the electron grating formation and its decay is continuously probed by a delayed pulse k3. The obtained build-up and decay times are found to depend nearly linearly on the intensity of incident pulses k1 and k2 being on the order of several microseconds at low pump intensities. The PCP effect in ZnSe QW possesses a time-gating capability which can be used for real-time holographic imaging. In this work we demonstrate contrast enhanced real time holographic imaging (CEHI) of floating glass beads and of living unicellular animals (Paramecium and Euglena cells) in aqueous solution. We also demonstrate CEHI of a ~100 im thick wire concealed behind a layer of chicken skin. The results demonstrate the potential of PCP QWs for real-time and depth-resolved imaging of moving micrometer sized biological objects in transparent media or of obscured objects in turbid media.

  14. Differential Gene Expression in Explanted Human Retinal Pigment Epithelial Cells 24-Hours Post-Exposure to 532 nm, 3.0 ns Pulsed Laser Light and 1064 nm, 170 ps Pulsed Laser Light 12-Hours Post-Exposure: Results Compendium

    DTIC Science & Technology

    2004-06-01

    Additionally, we offer 3 conceptual cartoons outlining our vision for the future progres of laser bioeffects research, metabonomic risk assessment...future progress of laser bioeffects research, metabonomic risk assessment modeling and knowledge building from laser bioeffects data. BACKGROUND In the...our concepts of future laser bioeffects research directions (Figure 5), a metabonomic risk assessment model of laser tissue interaction (Figure 6

  15. Clinically insubstantial cognitive side effects of bitemporal electroconvulsive therapy at 0.5 msec pulse width.

    PubMed

    Warnell, Ronald L; Swartz, Conrad M; Thomson, Alice

    2011-11-01

    We measured cognitive side effects from bitemporal electroconvulsive therapy (ECT) using stimuli of 0.5 msec pulse width 900 milliamperes (mA). Mini-Mental State Exam (MMSE) and 21-item Hamilton Rating Scale for Depression (HRSD-21) were rated within 36 hours before and 36 hours after a series of 6 bitemporal ECT sessions on 15 patients age ≥45. MMSE remained high after ECT (pre-ECT mean 29, standard deviation [SD] 1.60, post-ECT mean 28.53, SD 1.36) with no significant change. The mean HRSD-21 fell from 27.5 to 16.3. Post-ECT MMSE was significantly and markedly higher than in previous studies of bitemporal ECT; all had used ECT stimuli of pulse width at least 1 msec. With stimuli of 0.5 msec pulse width and 900 mA, 6 bitemporal ECTs did not decrease MMSE score. This result leaves no opportunity for further decrease in basic cognitive side effects, and complements published reports of stronger physiological effects with stimuli of 0.5 msec pulse width and 900 mA. ECT stimuli of 0.5 msec pulse width and 900 mA are more desirable than wider pulse widths. Six bitemporal ECT sessions using these stimuli generally will not have more cognitive side effects than treatments with other placements, allowing maintenance of full efficacy with clinically insubstantial side effects.

  16. 40 CFR 92.204 - Designation of engine families.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... stroke dimensions; (4) The approximate intake and exhaust event timing and duration (valve or port); (5... shutters, etc.); (3) The approximate bore and stroke dimensions; (4) The approximate location of the intake...

  17. 40 CFR 92.204 - Designation of engine families.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... stroke dimensions; (4) The approximate intake and exhaust event timing and duration (valve or port); (5... shutters, etc.); (3) The approximate bore and stroke dimensions; (4) The approximate location of the intake...

  18. 40 CFR 92.204 - Designation of engine families.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... stroke dimensions; (4) The approximate intake and exhaust event timing and duration (valve or port); (5... shutters, etc.); (3) The approximate bore and stroke dimensions; (4) The approximate location of the intake...

  19. 40 CFR 92.204 - Designation of engine families.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... stroke dimensions; (4) The approximate intake and exhaust event timing and duration (valve or port); (5... shutters, etc.); (3) The approximate bore and stroke dimensions; (4) The approximate location of the intake...

  20. 40 CFR 92.204 - Designation of engine families.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... stroke dimensions; (4) The approximate intake and exhaust event timing and duration (valve or port); (5... shutters, etc.); (3) The approximate bore and stroke dimensions; (4) The approximate location of the intake...

  1. Adaptive-randomised self-calibration of electro-mechanical shutters for space imaging

    NASA Astrophysics Data System (ADS)

    De Cecco, Mariolino; Debei, Stefano; Zaccariotto, Mirco; Pertile, Marco

    2006-11-01

    This work describes the self-calibration of a high-precision open-loop mechanism. The self-calibration method is applied to a mechanical shutter for space applications, which was launched onboard the ESA-ROSETTA mission (launch: 2 March 2004). It is based on an adaptive 'model reference' and a 'randomised' search method which may be generalised to applications in which high performance and functionality are strongly interconnected. The method makes use of an adaptive 'model-reference' control approach [K.J. Astrom, B. Wittenmark, On self-tuning regulators Automatica 9 (1973) 185-199 [16]; K.J. Astrom, Theory and application of adaptive control, in: Proceedings of the Eighth IFAC World Conference, Kyoto, Japan, 1981 [17]; D.E. Seborg, S.L. Shah, T.F. Edgar, Adaptive control strategies for process control, AIChE Journal 6(32) (1986) 881-895 [18

  2. Defining the safe current limit for opening ID photon shutter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seletskiy, S.

    The NSLS-II storage ring is protected from possible damage from insertion devices (IDs) synchrotron radiation by a dedicated active interlock system (AIS). It monitors electron beam position and angle and triggers beam drop if beam orbit exceeds the boundaries of pre-calculated active interlock envelope (AIE). The beamlines (BL) and beamline frontends (FE) are designed under assumption that the electron beam is interlocked within the AIE. For historic reasons the AIS engages the ID active interlock (AI-ID) at any non-zero beam current whenever the ID photon shutter (IDPS) is getting opened. Such arrangement creates major inconveniences for BLs commissioning. Apparently theremore » is some IDPS safe current limit (SCL) under which the IDPS can be opened without interlocking the e-beam. The goal of this paper is to find such limit.« less

  3. A Possible Method for the Discrimination of Spurious Events in Scintillation Chambers--Preliminary Results. Note No. 215; UN POSSIBILE METODO PER LA DISCRIMINAZIONE DI EVENTI SPURI IN CAMERA A SCINTILLE--RISULTATI PRELIMINARI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habel, R.; Letardi, T.

    1963-10-30

    In some studies with scintillation chambers, the problem of discriminating between the events generated by one or more ionizing particles and a spontaneous shower between the gaps of the chamber is presented. One element of difference between the two events is the delay of the spurious scintillation with respect to that produced by passage of a particle. The use of a fast shutter whose open time is of the order of the delay would provide a possible method for the discrimination between true and spurious events. The experimental apparatus used and the types of measurements made to determine if suchmore » a shutter arrangement would be feasible are described. (J.S.R.)« less

  4. All-fiber 80-Gbit/s wavelength converter using 1-m-long Bismuth Oxide-based nonlinear optical fiber with a nonlinearity gamma of 1100 W-1km-1.

    PubMed

    Lee, Ju Han; Kikuchi, Kazuro; Nagashima, Tatsuo; Hasegawa, Tomoharu; Ohara, Seiki; Sugimoto, Naoki

    2005-04-18

    We experimentally demonstrate the use of our fabricated 1-m-long Bi2O3 optical fiber (Bi-NLF) with an ultra-high nonlinearity of ~1100 W-1km-1 for wavelength conversion of OTDM signals. With successfully performed fusion splicing of the Bi-NLF to conventional silica fibers an all-fiber wavelength converter is readily implemented by use of a conventional Kerr shutter configuration. Owing to the extremely short fiber length, no additional scheme was employed for suppression of signal polarization fluctuation induced by local birefringence fluctuation, which is usually observed in a long-fiber Kerr shutter. The wavelength converter, composed of the 1-m Bi-NLF readily achieves error-free wavelength conversion of an 80-Gbit/s input signal.

  5. Specialised use of working memory by Portia africana, a spider-eating salticid.

    PubMed

    Cross, Fiona R; Jackson, Robert R

    2014-03-01

    Using expectancy-violation methods, we investigated the role of working memory in the predatory strategy of Portia africana, a salticid spider from Kenya that preys by preference on other spiders. One of this predator's tactics is to launch opportunistic leaping attacks on to other spiders in their webs. Focussing on this particular tactic, our experiments began with a test spider on a ramp facing a lure (dead prey spider mounted on a cork disc) that could be reached by leaping. After the test spider faced the lure for 30 s, we blocked the test spider's view of the lure by lowering an opaque shutter before the spider leapt. When the shutter was raised 90 s later, either the same lure came into view again (control) or a different lure came into view (experimental: different prey type in same orientation or same prey type in different orientation). We recorded attack frequency (number of test spiders that leapt at the lure) and attack latency (time elapsing between shutter being raised and spiders initiating a leap). Attack latencies in control trials were not significantly different from attack latencies in experimental trials, regardless of whether it was prey type or prey orientation that changed in the experimental trials. However, compared with test spiders in the no-change control trials, significantly fewer test spiders leapt when prey type changed. There was no significant effect on attack frequency when prey orientation changed. These findings suggest that this predator represents prey type independently of prey orientation.

  6. Optical bi-stable shutter development/improvement

    NASA Astrophysics Data System (ADS)

    Lizon, J. L.; Haddad, N.; Castillo, R.

    2012-09-01

    Two of the VLT instruments (Giraffe and VIMOS) are using the large magnetic E/150 from Prontor (with an aperture diameter of 150 mm). As we were facing an unacceptable number of failures with this component some improvement plan was discussed already in 2004. The final decision for starting this program was conditioned by the decision from the constructor to stop the production. The opportunity was taken to improve the design building a fully bi-stable mechanism in order to reduce the thermal dissipation. The project was developed in collaboration between the two main ESO sites doing the best use of the manpower and of the technical capability available at the two centers. The project took advantage of the laser Mask Manufacturing Unit and the invar sheets used to prepare the VIMOS MOS mask to fabricate the shutter petals. Our paper describes the development including the intensive and long optimization period. To conclude this optimization we proceed with a long life test on two units. These units have demonstrate a very high level of reliability (up to 100 000 cycles without failure which can be estimated to an equivalent 6 years of operation of the instrument) A new bi-stable shutter driver and controller have also been developed. Some of the highlights of this unit are the fully configurable coil driving parameters, usage of braking strategy to dump mechanical vibration and reduce mechanical wearing, configurable usage of OPEN and CLOSE sensors, non volatile storage of parameters, user friendly front panel interface.

  7. Morning pulse pressure is associated more strongly with elevated albuminuria than systolic blood pressure in patients with type 2 diabetes mellitus: post hoc analysis of a cross-sectional multicenter study.

    PubMed

    Ushigome, Emi; Fukui, Michiaki; Hamaguchi, Masahide; Matsumoto, Shinobu; Mineoka, Yusuke; Nakanishi, Naoko; Senmaru, Takafumi; Yamazaki, Masahiro; Hasegawa, Goji; Nakamura, Naoto

    2013-09-01

    Recently, focus has been directed toward pulse pressure as a potentially independent risk factor for micro- and macrovascular disease. This study was designed to examine the relationship between pulse pressure taken at home and elevated albuminuria in patients with type 2 diabetes. This study is a post hoc analysis of a cross-sectional multicenter study. Home blood pressure measurements were performed for 14 consecutive days in 858 patients with type 2 diabetes. We investigated the relationship between systolic blood pressure or pulse pressure in the morning or in the evening and urinary albumin excretion using univariate and multivariate analyses. Furthermore, we measured area under the receiver-operating characteristic curve (AUC) to compare the ability to identify elevated albuminuria, defined as urinary albumin excretion equal to or more than 30 mg/g creatinine, of systolic blood pressure or pulse pressure. Morning systolic blood pressure (β=0.339, P<0.001) and morning pulse pressure (β=0.378, P<0.001) were significantly associated with logarithm of urinary albumin excretion independent of other potential co-factors. AUC for elevated albuminuria in morning systolic blood pressure and morning pulse pressure were 0.668 (0.632-0.705; P<0.001) and 0.694 (0.659-0.730; P<0.001), respectively. AUC of morning pulse pressure was significantly greater than that of morning systolic blood pressure (P=0.040). Our findings implicate that morning pulse pressure is associated with elevated albuminuria in patients with type 2 diabetes, which suggests that lowering morning pulse pressure could prevent the development and progression of diabetic nephropathy. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. Hydroxyapatite thin films grown by pulsed laser deposition and matrix assisted pulsed laser evaporation: Comparative study

    NASA Astrophysics Data System (ADS)

    Popescu-Pelin, G.; Sima, F.; Sima, L. E.; Mihailescu, C. N.; Luculescu, C.; Iordache, I.; Socol, M.; Socol, G.; Mihailescu, I. N.

    2017-10-01

    Pulsed Laser Deposition (PLD) and Matrix Assisted Pulsed Laser Evaporation (MAPLE) techniques were applied for growing hydroxyapatite (HA) thin films on titanium substrates. All experiments were conducted in a reaction chamber using a KrF* excimer laser source (λ = 248 nm, τFWHM ≈ 25 ns). Half of the samples were post-deposition thermally treated at 500 °C in a flux of water vapours in order to restore crystallinity and improve adherence. Coating surface morphologies and topographies specific to the deposition method were evidenced by scanning electron, atomic force microscopy investigations and profilometry. They were shown to depend on deposition technique and also on the post-deposition treatment. Crystalline structure of the coatings evaluated by X-ray diffraction was improved after thermal treatment. Biocompatibility of coatings, cellular adhesion, proliferation and differentiation tests were conducted using human mesenchymal stem cells (MSCs). Results showed that annealed MAPLE deposited HA coatings were supporting MSCs proliferation, while annealed PLD obtained films were stimulating osteogenic differentiation.

  9. The influence of post-deposition annealing on the structure, morphology and luminescence properties of pulsed laser deposited La0.5Gd1.5SiO5 doped Dy3+ thin films

    NASA Astrophysics Data System (ADS)

    Ogugua, Simon N.; Swart, Hendrik C.; Ntwaeaborwa, Odireleng M.

    2018-04-01

    The influence of post-deposition annealing on the structure, particle morphology and photoluminescence properties of dysprosium (Dy3+) doped La0.5Gd1.5SiO5 thin films grown on Si(111) substrates at different substrate temperatures using pulsed laser deposition (PLD) technique were studied. The X-ray diffractometer results showed an improved crystallinity after post-annealing. The topography and morphology of the post-annealed films were studied using atomic force microscopy and field emission scanning electron microscopy respectively. The elemental composition in the surface region of the films were analyzed using energy dispersive X-ray spectroscopy. The photoluminescence studies showed an improved luminescent after post-annealing. The cathodoluminescence properties of the films are also reported. The CIE colour coordinates calculated from the photoluminescence and cathodoluminescence data suggest that the films can have potential application in white light emitting diode (LED) and field emission display (FED) applications.

  10. Multiloop Rapid-Rise/Rapid Fall High-Voltage Power Supply

    NASA Technical Reports Server (NTRS)

    Bearden, Douglas

    2007-01-01

    A proposed multiloop power supply would generate a potential as high as 1.25 kV with rise and fall times <100 s. This power supply would, moreover, be programmable to generate output potentials from 20 to 1,250 V and would be capable of supplying a current of at least 300 A at 1,250 V. This power supply is intended to be a means of electronic shuttering of a microchannel plate that would be used to intensify the output of a charge-coupled-device imager to obtain exposure times as short as 1 ms. The basic design of this power supply could also be adapted to other applications in which high voltages and high slew rates are needed. At the time of reporting the information for this article, there was no commercially available power supply capable of satisfying the stated combination of voltage, rise-time, and fall-time requirements. The power supply would include a preregulator that would be used to program a voltage 1/30 of the desired output voltage. By means of a circuit that would include a pulse-width modulator (PWM), two voltage doublers, and a transformer having two primary and two secondary windings, the preregulator output voltage would be amplified by a factor of 30. A resistor would limit the current by controlling a drive voltage applied to field-effect transistors (FETs) during turn-on of the PWM. Two feedback loops would be used to regulate the high output voltage. A pulse transformer would be used to turn on four FETs to short-circuit output capacitors when the outputs of the PWM were disabled. Application of a 0-to-5-V square to a PWM shut-down pin would cause a 20-to-1,250-V square wave to appear at the output.

  11. High-Voltage Power Supply With Fast Rise and Fall Times

    NASA Technical Reports Server (NTRS)

    Bearden, Douglas B.; Acker, Richard M.; Kapuslka, Robert E.

    2007-01-01

    A special-purpose high-voltage power supply can be electronically switched on and off with fast rise and fall times, respectively. The output potential is programmable from 20 to 1,250 V. An output current of 50 A can be sustained at 1,250 V. The power supply was designed specifically for electronically shuttering a microchannel plate in an x-ray detector that must operate with exposure times as short as 1 ms. The basic design of the power supply is also adaptable to other applications in which there are requirements for rapid slewing of high voltages. The power-supply circuitry (see figure) includes a preregulator, which is used to program the output at 1/30 of the desired output potential. After the desired voltage has been set, the outputs of a pulse width modulator (PWM) are enabled and used to amplify the preregulator output potential by 30. The amplification is achieved by use of two voltage doublers with a transformer that has two primary and two secondary windings. A resistor is used to limit the current by controlling the drive voltage of two field-effect transistors (FETs) during turn-on of the PWM. A pulse transformer is used to turn on four FETs to short-circuit four output capacitors when the outputs of the PWM have been disabled. The most notable aspects of the performance of the power supply are a rise time of only 80 s and a fall time of only 60 s at a load current of 50 A or less. Another notable aspect is that the application of a 0-to-5-V square wave to a shutdown pin of the PWM causes the production of a 0-to-1,250-V square wave at the output terminals.

  12. Effect of Electromagnetic Pulses (EMP) on associative learning in mice and a preliminary study of mechanism.

    PubMed

    Chen, Yong Bin; Li, Jing; Liu, Jun Ye; Zeng, Li Hua; Wan, Yi; Li, Yu Rong; Ren, Dongqing; Guo, G Z

    2011-12-01

    To investigate the effects of electromagnetic pulses (EMP) on associative learning in mice and test a preliminary mechanism for these effects. A tapered parallel plate gigahertz transverse electromagnetic (GTEM) cell with a flared rectangular coaxial transmission line was used to expose male BALB/c mice to EMP (peak-intensity 400 kV/m, rise-time 10 ns, pulse-width 350 ns, 0.5 Hz and total 200 pulses). Concurrent sham-exposed mice were used as a control. Associative learning, oxidative stress in the brain, serum chemistry and the protective action of tocopherol monoglucoside (TMG) in mice were measured, respectively. (1) Twelve hour and 1 day post EMP exposure associative learning was reduced significantly compared with sham control (p<0.05) but recovered at 2 d post EMP exposure. (2) Compared with the sham control, lipid peroxidation of brain tissue and chemiluminescence (CL) intensity increased significantly (p<0.05), while the activity of the antioxidant enzymes Superoxide Dismutase [SOD], Glutathione [GSH], Glutathione Peroxidase [GSH-Px], Catalase [CAT]) decreased significantly (p<0.05) at 3 h, 6 h, 12 h and 1 d post EMP exposure. All these parameters recovered at 2 d post EMP exposure. (3) No significant differences between the sham control group and EMP exposed group were observed in serum cholesterol and triglycerides. (4) Pretreatment of mice with TMG showed protective effects to EMP exposure. EMP exposure significantly decreased associative learning in mice and TMG acted as an effective protective agent from EMP exposure. This mechanism could involve an increase of oxidative stress in brain by EMP exposure.

  13. Periodic structure with a periodicity of 2-3.5 μm on crystalline TiO2 induced by unpolarized KrF excimer lasers

    NASA Astrophysics Data System (ADS)

    He, Rong; Ma, Hongliang; Zheng, Jiahui; Han, Yongmei; Lu, Yuming; Cai, Chuanbing

    2016-08-01

    Laser-induced periodic surface structures (LIPSS) were processed on the TiO2 bulk surface under the irradiation of 248 nm unpolarized KrF excimer laser pulses in air. Spatial LIPSS periods ranging from 2 to 3.5 μm are ascribed to the capillary wave. These microstructures were analyzed at different laser pulse numbers with the laser energy from 192 to 164 mJ. The scanning electron microscopy results indicated eventually stripes that have been disrupted as the increase in the laser pulse numbers, which is reasonably explained by the energy accumulating effect. In addition, investigations were concentrated on the surface modifications at pre-focal plane, focal plane and post-focal plane in the same defocusing amount. Compared with condition at pre-focal plane, in addition to the plasma produced at target, the air was also breakdown for the situation of post-focal plane. So it was reasonable that stripes appeared at pre-focal plane but not at post-focal plane.

  14. Improving quality of laser scanning data acquisition through calibrated amplitude and pulse deviation measurement

    NASA Astrophysics Data System (ADS)

    Pfennigbauer, Martin; Ullrich, Andreas

    2010-04-01

    Newest developments in laser scanner technologies put surveyors in the position to comply with the ever increasing demand of high-speed, high-accuracy, and highly reliable data acquisition from terrestrial, mobile, and airborne platforms. Echo digitization in pulsed time-of-flight laser ranging has demonstrated its superior performance in the field of bathymetry and airborne laser scanning for more than a decade, however at the cost of somewhat time consuming off line post processing. State-of-the-art online waveform processing as implemented in RIEGL's V-Line not only saves users post-processing time to obtain true 3D point clouds, it also adds the assets of calibrated amplitude and reflectance measurement for data classification and pulse deviation determination for effective and reliable data validation. We present results from data acquisitions in different complex target situations.

  15. 6. Historic American Buildings Survey Josiah T. Tubby, Photographer September ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Historic American Buildings Survey Josiah T. Tubby, Photographer September 1936 SLIDING SHUTTERS (S. W. wall sitting room) - Jefferds Tavern, Harraseekit Road (moved to U.S. Route 1A, York), Wells, York County, ME

  16. 5. Historic American Buildings Survey E. W. Russell, Photographer, June ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Historic American Buildings Survey E. W. Russell, Photographer, June 17, 1937 CLOSEUP OF THE LOWER SECTION OF FIRST STORY WINDOW ON FRONT, SHOWING SHUTTER AND HINGE. - Wewoka, Riser Mill Road, Sylacauga, Talladega County, AL

  17. 33. Photocopy of drawing STANDARD PLAN L4, SHEET 6 OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. Photocopy of drawing STANDARD PLAN L-4, SHEET 6 OF 8; CROSS SECTION, FRONT ELEVATION WITH SHUTTERS, FIRE FINDER - Suntop Lookout, Forest Road 510, Mt. Baker-Snoqualmie National Forest, Greenwater, Pierce County, WA

  18. Confocal multispot microscope for fast and deep imaging in semicleared tissues

    NASA Astrophysics Data System (ADS)

    Adam, Marie-Pierre; Müllenbroich, Marie Caroline; Di Giovanna, Antonino Paolo; Alfieri, Domenico; Silvestri, Ludovico; Sacconi, Leonardo; Pavone, Francesco Saverio

    2018-02-01

    Although perfectly transparent specimens are imaged faster with light-sheet microscopy, less transparent samples are often imaged with two-photon microscopy leveraging its robustness to scattering; however, at the price of increased acquisition times. Clearing methods that are capable of rendering strongly scattering samples such as brain tissue perfectly transparent specimens are often complex, costly, and time intensive, even though for many applications a slightly lower level of tissue transparency is sufficient and easily achieved with simpler and faster methods. Here, we present a microscope type that has been geared toward the imaging of semicleared tissue by combining multispot two-photon excitation with rolling shutter wide-field detection to image deep and fast inside semicleared mouse brain. We present a theoretical and experimental evaluation of the point spread function and contrast as a function of shutter size. Finally, we demonstrate microscope performance in fixed brain slices by imaging dendritic spines up to 400-μm deep.

  19. The Rocket Electric Field Sounding (REFS) program: Prototype design and successful first launch

    NASA Astrophysics Data System (ADS)

    Willett, J. C.; Curtis, D. C.; Driesman, A. R.; Longstreth, R. K.; Rison, W.; Winn, W. P.; Jones, J. J.

    1992-01-01

    The motivation, design, and successful first flight of a sounding rocket to measure profiles of vector electrostatic field in the lower troposphere are described. The design employs eight shutter field mills amd a corona-charging system in a manner similar to aircraft previously instrumented for the measurement of electric fields. A rocket offers significant advantages over an aircraft in simplicity and calibration. A single cylindrical rotor covering most of the payload acts as the shutter for all eight mills in this design. The cylindrical symmetry and circular cross sections of the vehicle facilitate straightforward calibration. Also included in the payload are a pressure sensor, a longitudinal accelerometer, a transverse magnometer, and a novel cloud-penetration detector. A fair-weather test flight at the NASA Wallops Flight Facility demonstrated the workability of the basic design and identified a few necessary modifications.

  20. Design, Qualification and Lessons Learned of the Shutter Calibration Mechanism for EnMAP Mission

    NASA Astrophysics Data System (ADS)

    Schmidt, Tilo; Muller, Silvio; Bergander, Arvid; Zajac, Kai; Seifart, Klaus

    2015-09-01

    The Shutter Calibration Mechanism (SCM) Assembly is one of three mechanisms which are developed by HTS for the EnMAP instrument in subcontract to OHB System AG Munich. EnMAP is the Environmental Mapping and Analysis Program of the German Space Agency DLR.The binary rotary encoder of the SCM using hall-effect sensors was already presented during ESMATS 2011. This paper summarizes the main functions and design features of the Hardware and focuses on qualification testing which has finished successfully in 2014. Of particular interest is the functional testing of the main drive including the precise hall-effect position sensing system and the test of the fail safe mechanism. In addition to standard test campaign required for QM also a shock emission measurement of the fail safe mechanism activation was conducted.Test conduction and results will be presented with focus on deviations from the expected behaviour, mitigation measures and on lessons learned.

  1. An analysis of new techniqes for radiometric correction of LANDSAT-4 Thematic Mapper images. [Terrebonne Bay, Louisiana and Grand Bahamas scenes

    NASA Technical Reports Server (NTRS)

    Kogut, J.; Larduinat, E.; Fitzgerald, M.

    1983-01-01

    The utility of methods for generating TM RLUTS which can improve the quality of the resultant images was investigated. The TM-CCT-ADDS tape was changed to account for a different collection window for the calibration data. Several scenes of Terrebonne Bay, Louisiana and the Grand Bahamas were analyzed to evaluate the radiometric corrections operationally applied to the image data and to investigate several techniques for reducing striping in the images. Printer plots for the TM shutter data were produced and detector statistics were compiled and plotted. These statistics included various combinations of the average shutter counts for each scan before and after DC restore for forward and reverse scans. Results show that striping is caused by the detectors becoming saturated when they view a bright cloud and depress the DC restore level.

  2. Electrically optofluidic zoom system with a large zoom range and high-resolution image.

    PubMed

    Li, Lei; Yuan, Rong-Ying; Wang, Jin-Hui; Wang, Qiong-Hua

    2017-09-18

    We report an electrically controlled optofluidic zoom system which can achieve a large continuous zoom change and high-resolution image. The zoom system consists of an optofluidic zoom objective and a switchable light path which are controlled by two liquid optical shutters. The proposed zoom system can achieve a large tunable focal length range from 36mm to 92mm. And in this tuning range, the zoom system can correct aberrations dynamically, thus the image resolution is high. Due to large zoom range, the proposed imaging system incorporates both camera configuration and telescope configuration into one system. In addition, the whole system is electrically controlled by three electrowetting liquid lenses and two liquid optical shutters, therefore, the proposed system is very compact and free of mechanical moving parts. The proposed zoom system has potential to take place of conventional zoom systems.

  3. Design and realization of an AEC&AGC system for the CCD aerial camera

    NASA Astrophysics Data System (ADS)

    Liu, Hai ying; Feng, Bing; Wang, Peng; Li, Yan; Wei, Hao yun

    2015-08-01

    An AEC and AGC(Automatic Exposure Control and Automatic Gain Control) system was designed for a CCD aerial camera with fixed aperture and electronic shutter. The normal AEC and AGE algorithm is not suitable to the aerial camera since the camera always takes high-resolution photographs in high-speed moving. The AEC and AGE system adjusts electronic shutter and camera gain automatically according to the target brightness and the moving speed of the aircraft. An automatic Gamma correction is used before the image is output so that the image is better for watching and analyzing by human eyes. The AEC and AGC system could avoid underexposure, overexposure, or image blurring caused by fast moving or environment vibration. A series of tests proved that the system meet the requirements of the camera system with its fast adjusting speed, high adaptability, high reliability in severe complex environment.

  4. Rapid Optical Shutter, Chopper, Modulator and Deflector

    NASA Technical Reports Server (NTRS)

    Danehy, Paul M. (Inventor)

    2017-01-01

    An optical device with a light source and a detector is provided. A digital micromirror device positioned between the detector and the light source may deflect light beams projected from the light source. An aperture in front of the detector may block an incoming light beam from the detector when the incoming light beam is incident on the detector outside of a passable incident range and including an aperture opening configured to pass the incoming light beam to the detector when the incoming light beam is incident on the detector within a passable incident range. The digital micromirror device may rotate between a first position causing the light beam to pass through the aperture opening and a second position causing the light beam to be blocked by the aperture. The optical device may be configured to operate as a shutter, chopper, modulator and/or deflector.

  5. A mixed reality approach for stereo-tomographic quantification of lung nodules.

    PubMed

    Chen, Mianyi; Kalra, Mannudeep K; Yun, Wenbing; Cong, Wenxiang; Yang, Qingsong; Nguyen, Terry; Wei, Biao; Wang, Ge

    2016-05-25

    To reduce the radiation dose and the equipment cost associated with lung CT screening, in this paper we propose a mixed reality based nodule measurement method with an active shutter stereo imaging system. Without involving hundreds of projection views and subsequent image reconstruction, we generated two projections of an iteratively placed ellipsoidal volume in the field of view and merging these synthetic projections with two original CT projections. We then demonstrated the feasibility of measuring the position and size of a nodule by observing whether projections of an ellipsoidal volume and the nodule are overlapped from a human observer's visual perception through the active shutter 3D vision glasses. The average errors of measured nodule parameters are less than 1 mm in the simulated experiment with 8 viewers. Hence, it could measure real nodules accurately in the experiments with physically measured projections.

  6. Rolling Shutter Effect aberration compensation in Digital Holographic Microscopy

    NASA Astrophysics Data System (ADS)

    Monaldi, Andrea C.; Romero, Gladis G.; Cabrera, Carlos M.; Blanc, Adriana V.; Alanís, Elvio E.

    2016-05-01

    Due to the sequential-readout nature of most CMOS sensors, each row of the sensor array is exposed at a different time, resulting in the so-called rolling shutter effect that induces geometric distortion to the image if the video camera or the object moves during image acquisition. Particularly in digital holograms recording, while the sensor captures progressively each row of the hologram, interferometric fringes can oscillate due to external vibrations and/or noises even when the object under study remains motionless. The sensor records each hologram row in different instants of these disturbances. As a final effect, phase information is corrupted, distorting the reconstructed holograms quality. We present a fast and simple method for compensating this effect based on image processing tools. The method is exemplified by holograms of microscopic biological static objects. Results encourage incorporating CMOS sensors over CCD in Digital Holographic Microscopy due to a better resolution and less expensive benefits.

  7. PIC simulations of post-pulse field reversal and secondary ionization in nanosecond argon discharges

    NASA Astrophysics Data System (ADS)

    Kim, H. Y.; Gołkowski, M.; Gołkowski, C.; Stoltz, P.; Cohen, M. B.; Walker, M.

    2018-05-01

    Post-pulse electric field reversal and secondary ionization are investigated with a full kinetic treatment in argon discharges between planar electrodes on nanosecond time scales. The secondary ionization, which occurs at the falling edge of the voltage pulse, is induced by charge separation in the bulk plasma region. This process is driven by a reverse in the electric field from the cathode sheath to the formerly driven anode. Under the influence of the reverse electric field, electrons in the bulk plasma and sheath regions are accelerated toward the cathode. The electron movement manifests itself as a strong electron current generating high electron energies with significant electron dissipated power. Accelerated electrons collide with Ar molecules and an increased ionization rate is achieved even though the driving voltage is no longer applied. With this secondary ionization, in a single pulse (SP), the maximum electron density achieved is 1.5 times higher and takes a shorter time to reach using 1 kV 2 ns pulse as compared to a 1 kV direct current voltage at 1 Torr. A bipolar dual pulse excitation can increase maximum density another 50%–70% above a SP excitation and in half the time of RF sinusoidal excitation of the same period. The first field reversal is most prominent but subsequent field reversals also occur and correspond to electron temperature increases. Targeted pulse designs can be used to condition plasma density as required for fast discharge applications.

  8. Use of biomedical photonics in gynecological surgery: a uterine transplantation model

    PubMed Central

    Saso, Srdjan; Clancy, Neil T; Jones, Benjamin P; Bracewell-Milnes, Timothy; Al-Memar, Maya; Cannon, Eleanor M; Ahluwalia, Simran; Yazbek, Joseph; Thum, Meen-Yau; Bourne, Tom; Elson, Daniel S; Smith, James Richard; Ghaem-Maghami, Sadaf

    2018-01-01

    Aim: Uterine transplantation (UTx) has been proposed as a treatment for permanent absolute uterine factor infertility. The study aims were to compare pulse oximetry and multispectral imaging (MSI), for intraoperative tracking of uterine oxygen saturation in animal UTx models (rabbit and sheep). Results/methodology: Imaging results confirmed the re-establishment of adequate perfusion in the transplanted organ after surgery. Comparison of oxygen saturation values between the pre-UTx donor and post-UTx recipient, and pre-UTx and post-UTx recipient reveals a statistically significant decrease in saturation levels post-UTx. Conclusion: The use of MSI is the first case in gynecology and has demonstrated promise of possible future human use. MSI technique has advantages over pulse oximetry – it provides spatial information in a real-time, noncontact manner. PMID:29682321

  9. Delayed action does not always require the ventral stream: a study on a patient with visual form agnosia.

    PubMed

    Hesse, Constanze; Schenk, Thomas

    2014-05-01

    It has been suggested that while movements directed at visible targets are processed within the dorsal stream, movements executed after delay rely on the visual representations of the ventral stream (Milner & Goodale, 2006). This interpretation is supported by the observation that a patient with ventral stream damage (D.F.) has trouble performing accurate movements after a delay, but performs normally when the target is visible during movement programming. We tested D.F.'s visuomotor performance in a letter-posting task whilst varying the amount of visual feedback available. Additionally, we also varied whether D.F. received tactile feedback at the end of each trial (posting through a letter box vs posting on a screen) and whether environmental cues were available during the delay period (removing the target only vs suppressing vision completely with shutter glasses). We found that in the absence of environmental cues patient D.F. was unaffected by the introduction of delay and performed as accurately as healthy controls. However, when environmental cues and vision of the moving hand were available during and after the delay period, D.F.'s visuomotor performance was impaired. Thus, while healthy controls benefit from the availability of environmental landmarks and/or visual feedback of the moving hand, such cues seem less beneficial to D.F. Taken together our findings suggest that ventral stream damage does not always impact the ability to make delayed movements but compromises the ability to use environmental landmarks and visual feedback efficiently. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Molecular Dynamics Underlie the Nature of MRI Signals: The NMR Shutter-Speed

    NASA Astrophysics Data System (ADS)

    Springer, Charles S., Jr.

    2007-03-01

    Motions of the spin-bearing molecules can have profound effects on the very nature (the exponentiality) of the macroscopic NMR signal. Quantitative mechanistic protocols often involve varying the equilibrium molecular kinetics (usually by temperature change) relative to the ``NMR time-scale'' (SS-1), usually ill-defined as the absolute difference of resonance frequencies [|δφ|] in sites between which spins are exchanged. This holds true for the equilibrium water molecule exchange between tissue compartments and distinct populations. However, in vivo studies must [by regulation] be isothermal, and the tissue ^1H2O MRI signals remain essentially isochronous [δφ = 0]. In NMR, an equilibrium process is manifest in the context of its ``exchange condition.'' It only ``appears'' to be fast or slow by comparison of its actual rate constant with its system ``shutter-speed'' (SS). [A nonzero δφ is the first, but not only, SS: its dimension is reciprocal time.] The process kinetics can be measured only if its NMR condition is varied at least partway between the fast- and slow exchange limits. In an isothermal study with no catalyst, this can be accomplished only by varying the pertinent SS. An MRI contrast reagent (CR) increases the laboratory frame ^1H2O relaxation rate constant, Ri [≡ (Ti)-1; i = 1,2]. For an isochronous exchange process, the SS is the intrinsic |δRi| for the sites. In quantitative dynamic-contrast-enhanced (DCE) studies, analytical pharmacokinetic modeling is accomplished on region-of-interest (ROI) or pixel by pixel ^1H2O signal time-courses following bolus CR injections. Accounting for the equilibrium transendothelial and transcytolemmal water interchange processes (a three-site exchange situation) is crucial for modeling accuracy: the relevant SS values vary during the CR bolus passage. This is so for DCE studies of cancer, multiple sclerosis, and myocardial blood flow variation. It is necessary for the successful discrimination of malignant and benign breast and prostate lesions. One can expect a SS for almost any NMR experiment. This includes diffusion weighted and rotating-frame longitudinal relaxation of in vivo ^1H2O signals. In these latter cases, the pertinent SS can be manipulated solely by adjustment of pulse sequence parameters, leading to completely non-invasive protocols.

  11. Multiple serial picture presentation with millisecond resolution using a three-way LC-shutter-tachistoscope

    PubMed Central

    Fischmeister, Florian Ph.S.; Leodolter, Ulrich; Windischberger, Christian; Kasess, Christian H.; Schöpf, Veronika; Moser, Ewald; Bauer, Herbert

    2010-01-01

    Throughout recent years there has been an increasing interest in studying unconscious visual processes. Such conditions of unawareness are typically achieved by either a sufficient reduction of the stimulus presentation time or visual masking. However, there are growing concerns about the reliability of the presentation devices used. As all these devices show great variability in presentation parameters, the processing of visual stimuli becomes dependent on the display-device, e.g. minimal changes in the physical stimulus properties may have an enormous impact on stimulus processing by the sensory system and on the actual experience of the stimulus. Here we present a custom-built three-way LC-shutter-tachistoscope which allows experimental setups with both, precise and reliable stimulus delivery, and millisecond resolution. This tachistoscope consists of three LCD-projectors equipped with zoom lenses to enable stimulus presentation via a built-in mirror-system onto a back projection screen from an adjacent room. Two high-speed liquid crystal shutters are mounted serially in front of each projector to control the stimulus duration. To verify the intended properties empirically, different sequences of presentation times were performed while changes in optical power were measured using a photoreceiver. The obtained results demonstrate that interfering variabilities in stimulus parameters and stimulus rendering are markedly reduced. Together with the possibility to collect external signals and to send trigger-signals to other devices, this tachistoscope represents a highly flexible and easy to set up research tool not only for the study of unconscious processing in the brain but for vision research in general. PMID:20122963

  12. Ultra-Compact Accelerator Technologies for Application in Nuclear Techniques

    NASA Astrophysics Data System (ADS)

    Sampayan, S.; Caporaso, G.; Chen, Y.-J.; Carazo, V.; Falabella, S.; Guethlein, G.; Guse, S.; Harris, J. R.; Hawkins, S.; Holmes, C.; Krogh, M.; Nelson, S.; Paul, A. C.; Pearson, D.; Poole, B.; Schmidt, R.; Sanders, D.; Selenes, K.; Sitaraman, S.; Sullivan, J.; Wang, L.; Watson, J.

    2009-12-01

    We report on compact accelerator technology development for potential use as a pulsed neutron source quantitative post verifier. The technology is derived from our on-going compact accelerator technology development program for radiography under the US Department of Energy and for a clinic sized compact proton therapy systems under an industry sponsored Cooperative Research and Development Agreement. The accelerator technique relies on the synchronous discharge of a prompt pulse generating stacked transmission line structure with the beam transit. The goal of this technology is to achieve ˜10 MV/m gradients for 10 s of nanoseconds pulses and ˜100 MV/m gradients for ˜1 ns systems. As a post verifier for supplementing existing x-ray equipment, this system can remain in a charged, stand-by state with little or no energy consumption. We describe the progress of our overall component development effort with the multilayer dielectric wall insulators (i.e., the accelerator wall), compact power supply technology, kHz repetition-rate surface flashover ion sources, and the prompt pulse generation system consisting of wide-bandgap switches and high performance dielectric materials.

  13. Front-surface fabrication of moderate aspect ratio micro-channels in fused silica by single picosecond Gaussian-Bessel laser pulse

    NASA Astrophysics Data System (ADS)

    Liu, Xin; Sanner, Nicolas; Sentis, Marc; Stoian, Razvan; Zhao, Wei; Cheng, Guanghua; Utéza, Olivier

    2018-02-01

    Single-shot Gaussian-Bessel laser beams of 1 ps pulse duration and of 0.9 μm core size and 60 μm depth of focus are used for drilling micro-channels on front side of fused silica in ambient condition. Channels ablated at different pulse energies are fully characterized by AFM and post-processing polishing procedures. We identify experimental energy conditions (typically 1.5 µJ) suitable to fabricate non-tapered channels with mean diameter of 1.2 µm and length of 40 μm while maintaining an utmost quality of the front opening of the channels. In addition, by further applying accurate post-polishing procedure, channels with high surface quality and moderate aspect ratio down to a few units are accessible, which would find interest in the surface micro-structuring of materials, with perspective of further scalability to meta-material specifications.

  14. Computational analysis of current-loss mechanisms in a post-hole convolute driven by magnetically insulated transmission lines

    DOE PAGES

    Rose, D.  V.; Madrid, E.  A.; Welch, D.  R.; ...

    2015-03-04

    Numerical simulations of a vacuum post-hole convolute driven by magnetically insulated vacuum transmission lines (MITLs) are used to study current losses due to charged particle emission from the MITL-convolute-system electrodes. This work builds on the results of a previous study [E.A. Madrid et al. Phys. Rev. ST Accel. Beams 16, 120401 (2013)] and adds realistic power pulses, Ohmic heating of anode surfaces, and a model for the formation and evolution of cathode plasmas. The simulations suggest that modestly larger anode-cathode gaps in the MITLs upstream of the convolute result in significantly less current loss. In addition, longer pulse durations leadmore » to somewhat greater current loss due to cathode-plasma expansion. These results can be applied to the design of future MITL-convolute systems for high-current pulsed-power systems.« less

  15. A Wearable and Highly Sensitive Graphene Strain Sensor for Precise Home-Based Pulse Wave Monitoring.

    PubMed

    Yang, Tingting; Jiang, Xin; Zhong, Yujia; Zhao, Xuanliang; Lin, Shuyuan; Li, Jing; Li, Xinming; Xu, Jianlong; Li, Zhihong; Zhu, Hongwei

    2017-07-28

    Profuse medical information about cardiovascular properties can be gathered from pulse waveforms. Therefore, it is desirable to design a smart pulse monitoring device to achieve noninvasive and real-time acquisition of cardiovascular parameters. The majority of current pulse sensors are usually bulky or insufficient in sensitivity. In this work, a graphene-based skin-like sensor is explored for pulse wave sensing with features of easy use and wearing comfort. Moreover, the adjustment of the substrate stiffness and interfacial bonding accomplish the optimal balance between sensor linearity and signal sensitivity, as well as measurement of the beat-to-beat radial arterial pulse. Compared with the existing bulky and nonportable clinical instruments, this highly sensitive and soft sensing patch not only provides primary sensor interface to human skin, but also can objectively and accurately detect the subtle pulse signal variations in a real-time fashion, such as pulse waveforms with different ages, pre- and post-exercise, thus presenting a promising solution to home-based pulse monitoring.

  16. PubMed Central

    PIUMETTO, E.; SAMMARTANO, A.M.; MEINARDI, G.; DAGNA, F.; GERVASIO, F.C.; ALBERA, R.

    2011-01-01

    SUMMARY Obstructive sleep apnoea syndrome in a child is characterized by prolonged episodes of obstructive hypopnoea and/or apnoea of upper airway leading to morbidity. The most common risk factor is adeno-tonsillar hypertrophy. Obstructive sleep apnoea syndrome diagnosis is based on clinical ENT evaluation and an instrumental approach, such as pulse oximetry or the gold standard overnight polysomnography. The aim is to establish, in a population of children with suspected obstructive sleep apnoea syndrome, the frequency of this disorder, the effect of adenotonsillectomy and the risk of post-operative complications. A total of 481 patients (297 male, 184 female) with suspected obstructive sleep apnoea syndrome (aged 2-14 years) were evaluated between March 2007 and April 2010 and divided into 3 morphological phenotypes: classic, adult and congenital. All patients underwent ENT assessment and a pulse oximetry with 4 channels cardiopulmonary monitoring. The examination following the Brouillette criteria was defined as negative, positive or inconclusive; when positive, adenotonsillectomy was the first therapeutic approach. At 6 months after surgery, all patients underwent check-up pulse oximetry. Of the overall sample, 96% of the patients had a classical phenotype, 3% an adult type and 1% a congenital type. The monitoring resulted pathological in 19% (17% of them were at increased post-operative risk), negative in 61% and inconclusive in 20%. All 5 patients with congenital phenotype were positive. Of the positive patients, 86% underwent adenotonsillectomy and a control pulse oximetry 6 months thereafter, 96% resulted negative. Pulse oximetry was efficient in order to avoid incorrect surgery indications, improving appropriateness and safety of adenotonsillectomy in children with obstructive sleep apnoea syndrome. Adenotonsillectomy showed a success rate of 96% and there were no episodes of post-surgery complications in particular in those patients at increased risk. PMID:22058592

  17. Reliability and validity of a smartphone pulse rate application for the assessment of resting and elevated pulse rate.

    PubMed

    Mitchell, Katy; Graff, Megan; Hedt, Corbin; Simmons, James

    2016-08-01

    Purpose/hypothesis: This study was designed to investigate the test-retest reliability, concurrent validity, and the standard error of measurement (SEm) of a pulse rate assessment application (Azumio®'s Instant Heart Rate) on both Android® and iOS® (iphone operating system) smartphones as compared to a FT7 Polar® Heart Rate monitor. Number of subjects: 111. Resting (sitting) pulse rate was assessed twice and then the participants were asked to complete a 1-min standing step test and then immediately re-assessed. The smartphone assessors were blinded to their measurements. Test-retest reliability (intraclass correlation coefficient [ICC 2,1] and 95% confidence interval) for the three tools at rest (time 1/time 2): iOS® (0.76 [0.67-0.83]); Polar® (0.84 [0.78-0.89]); and Android® (0.82 [0.75-0.88]). Concurrent validity at rest time 2 (ICC 2,1) with the Polar® device: IOS® (0.92 [0.88-0.94]) and Android® (0.95 [0.92-0.96]). Concurrent validity post-exercise (time 3) (ICC) with the Polar® device: iOS® (0.90 [0.86-0.93]) and Android® (0.94 [0.91-0.96]). The SEm values for the three devices at rest: iOS® (5.77 beats per minute [BPM]), Polar® (4.56 BPM) and Android® (4.96 BPM). The Android®, iOS®, and Polar® devices showed acceptable test-retest reliability at rest and post-exercise. Both the smartphone platforms demonstrated concurrent validity with the Polar® at rest and post-exercise. The Azumio® Instant Heart Rate application when used by either platform appears to be a reliable and valid tool to assess pulse rate in healthy individuals.

  18. Short-Term Effects of Pulsed Radiofrequency on Chronic Refractory Cervical Radicular Pain

    PubMed Central

    Choi, Gyu-Sik; Cho, Yun-Woo; Lee, Dong-Kyu

    2011-01-01

    Objective To evaluate the short-term effectiveness of pulsed radiofrequency on the dorsal root ganglion (DRG) in patients with chronic refractory cervical radicular pain. Method Fifteen patients (13 males, 2 females; mean age, 55.9 years) with chronic radicular pain due to cervical disc herniation or foraminal stenosis refractory to active rehabilitative management, including transforaminal cervical epidural steroid injection and exercise, were selected. All patients received pulsed radiofrequency on the symptomatic cervical dorsal root ganglion and were carefully evaluated for neurologic deficits and side effects. The clinical outcomes were measured using a visual analogue scale (VAS) and a neck disability index (NDI) before treatment, one and three months after treatment. Successful pain relief was defined as a 50% or greater reduction in the VAS score as compared with the pre-treatment score. After three months, we categorized the patients' satisfaction. Results The average VAS for radicular pain was reduced significantly from 5.3 at pretreatment to 2.5 at 3 months post-treatment (p<0.05). Eleven of 15 patients (77.3%) after cervical pulsed RF stimulation reported pain relief of 50% or more at the 3 month follow-up. The average NDI was significantly reduced from 44.0% at pretreatment to 35.8% 3 months post-treatment (p<0.05). At 3 months post-treatment, eleven of fifteen patients (73.3%) were satisfied with their status. No adverse effects were observed. Conclusion The results demonstrate that the application of pulsed radiofrequency on DRG might be an effective short-term intervention for chronic refractory cervical radicular pain. Further studies, including a randomized controlled trial with long-term follow-up, are now needed. PMID:22506211

  19. Initiation of long, free-standing z discharges by CO2 laser gas heating

    NASA Astrophysics Data System (ADS)

    Niemann, C.; Tauschwitz, A.; Penache, D.; Neff, S.; Knobloch, R.; Birkner, R.; Presura, R.; Hoffmann, D. H. H.; Yu, S. S.; Sharp, W. M.

    2002-01-01

    High current discharge channels can neutralize both current and space charge of very intense ion beams. Therefore, they are considered an interesting solution for final focus and beam transport in a heavy ion beam fusion reactor. At the Gesellschaft für Schwerionenforschung accelerator facility, 50 cm long, free-standing discharge channels were created in a 60 cm diameter metallic chamber. Discharges with currents of 45 kA in 2 to 25 mbar ammonia (NH3) gas are initiated by a CO2 laser pulse along the channel axis before the capacitor bank is triggered. Resonant absorption of the laser, tuned to the v2 vibration of the ammonia molecule, causes strong gas heating. Subsequent expansion and rarefaction of the gas prepare the conditions for a stable discharge to fulfill the requirements for ion beam transport. The influence of an electric prepulse on the high current discharge was investigated. This article describes the laser-gas interaction and the discharge initiation mechanism. We found that channels are magnetohydrodynamic stable up to currents of 45 kA, measured by fast shutter and streak imaging techniques. The rarefaction of the laser heated gas is studied by means of a one-dimensional Lagrangian fluid code (CYCLOPS) and is identified as the dominant initiation mechanism of the discharge.

  20. High-speed imaging using 3CCD camera and multi-color LED flashes

    NASA Astrophysics Data System (ADS)

    Hijazi, Ala; Friedl, Alexander; Cierpka, Christian; Kähler, Christian; Madhavan, Vis

    2017-11-01

    This paper demonstrates the possibility of capturing full-resolution, high-speed image sequences using a regular 3CCD color camera in conjunction with high-power light emitting diodes of three different colors. This is achieved using a novel approach, referred to as spectral-shuttering, where a high-speed image sequence is captured using short duration light pulses of different colors that are sent consecutively in very close succession. The work presented in this paper demonstrates the feasibility of configuring a high-speed camera system using low cost and readily available off-the-shelf components. This camera can be used for recording six-frame sequences at frame rates up to 20 kHz or three-frame sequences at even higher frame rates. Both color crosstalk and spatial matching between the different channels of the camera are found to be within acceptable limits. A small amount of magnification difference between the different channels is found and a simple calibration procedure for correcting the images is introduced. The images captured using the approach described here are of good quality to be used for obtaining full-field quantitative information using techniques such as digital image correlation and particle image velocimetry. A sequence of six high-speed images of a bubble splash recorded at 400 Hz is presented as a demonstration.

  1. Tuned alexandrite laser for dentistry

    NASA Astrophysics Data System (ADS)

    Sulc, Jan; Jelinkova, Helena; Dostalova, Tatjana; Miyagi, Mitsunobu

    2000-04-01

    For medical applications tunable solid state laser system emitting a visible light in a region from 710 to 775 nm was developed. Laser head of this system was composed of alexandrite crystal rod (4 mm in diameter, 90 mm of length), two dielectric mirrors and tuning element (dispersing prism or thin-film polarizer). For Q-switching, three different optics shutters were proved: a saturable NC-dye or LiF crystal, LiNbO3 Pockels cell, and rotating prism. Maximum output energy in free-running and Q-switching regime was 400 mJ and 70 mJ, respectively. The pulse duration was 70 microsecond(s) in the free-running and 45 - 250 ns in Q-switching regime. The output free running laser radiation was guided via a multimode quartz fiber (1 m of length, core diameter 600 micrometers ) or via a special fluorocarbon polymer-coated silver hollow glass waveguide (0.62 m of length, inner diameter 1 mm). At first, this radiation with a laser fluence of 2.5 J/cm2 was used for an ablation of a dental calculus. Next, the laser radiation propagation in a root canal and its effect on bacteria was proved. The dissipated energy measurement was made inside and outside of the tooth. From the results follow that the alexandrite laser could be useful for medical applications.

  2. Reduced transpiration response to precipitation pulses precedes mortality in a piñon-juniper woodland subject to prolonged drought.

    PubMed

    Plaut, Jennifer A; Wadsworth, W Duncan; Pangle, Robert; Yepez, Enrico A; McDowell, Nate G; Pockman, William T

    2013-10-01

    Global climate change is predicted to alter the intensity and duration of droughts, but the effects of changing precipitation patterns on vegetation mortality are difficult to predict. Our objective was to determine whether prolonged drought or above-average precipitation altered the capacity to respond to the individual precipitation pulses that drive productivity and survival. We analyzed 5 yr of data from a rainfall manipulation experiment in piñon-juniper (Pinus edulis-Juniperus monosperma) woodland using mixed effects models of transpiration response to event size, antecedent soil moisture, and post-event vapor pressure deficit. Replicated treatments included irrigation, drought, ambient control and infrastructure control. Mortality was highest under drought, and the reduced post-pulse transpiration in the droughted trees that died was attributable to treatment effects beyond drier antecedent conditions and reduced event size. In particular, trees that died were nearly unresponsive to antecedent shallow soil moisture, suggesting reduced shallow absorbing root area. Irrigated trees showed an enhanced response to precipitation pulses. Prolonged drought initiates a downward spiral whereby trees are increasingly unable to utilize pulsed soil moisture. Thus, the additive effects of future, more frequent droughts may increase drought-related mortality. © 2013 The Authors. New Phytologist © 2013 New Phytologist Trust.

  3. Optically Activated Exciplex Shutter/Attenuator.

    DTIC Science & Technology

    radiation of a certain wavelength to excite a bi-molecular exciplex solution. The exciplex solution reacts to a range of radiation wavelengths whereas...optical elements prevent passage of radiation below and above the operative range of an exciplex solution such as anthracene and diethylaniline.

  4. Over atmospheric pressure flowing afterglow

    NASA Astrophysics Data System (ADS)

    Ganciu, Mihai; Orphal, Johannes; Vervloet, Michel; Pointu, Anne-Marie; Touzeau, Michel

    2002-10-01

    A Tabletop discharge * created above atmospheric pressure in a N2 gas flow, uses some 10 kV very fast high voltage pulses applied between needle electrodes with some 10 kHz repetition rate. It is followed by a post-discharge, in a plastic tube with 6-mm internal diameter. Adjusting the flow and the repetition rate, the post-discharge exhibits a surprisingly long size, 9-10 m, as shown by the tube fluorescence. Preliminary spectroscopic measurements demonstrate that fluorescence is due to internal gas excited molecules (CN and NH) that are locally created by active species interaction with organic impurities. The discharge emission spectrum evidences a high nitrogen atom production rate, much higher than attainable rate with a Dielectric Barrier Discharge with same applied voltage pulses. For small air quantities added in the post-discharge, spectrum exhibits rich UV range corresponding to NO excited states. Further studies will be devoted to the post-discharge kinetics and to possible applications to medical sterilization. *M. Ganciu, private communication

  5. Time-resolved atomic inner-shell spectroscopy

    NASA Astrophysics Data System (ADS)

    Drescher, M.; Hentschel, M.; Kienberger, R.; Uiberacker, M.; Yakovlev, V.; Scrinzi, A.; Westerwalbesloh, Th.; Kleineberg, U.; Heinzmann, U.; Krausz, F.

    2002-10-01

    The characteristic time constants of the relaxation dynamics of core-excited atoms have hitherto been inferred from the linewidths of electronic transitions measured by continuous-wave extreme ultraviolet or X-ray spectroscopy. Here we demonstrate that a laser-based sampling system, consisting of a few-femtosecond visible light pulse and a synchronized sub-femtosecond soft X-ray pulse, allows us to trace these dynamics directly in the time domain with attosecond resolution. We have measured a lifetime of 7.9-0.9+1.0fs of M-shell vacancies of krypton in such a pump-probe experiment.

  6. Economics of electron beam and electrical discharge processing for post-combustion NO(x) control in internal combustion engines

    NASA Astrophysics Data System (ADS)

    Penetrante, B. M.

    1993-08-01

    The physics and chemistry of non-thermal plasma processing for post-combustion NO(x) control in internal combustion engines are discussed. A comparison of electron beam and electrical discharge processing is made regarding their power consumption, radical production, NO(x) removal mechanisms, and by-product formation. Pollution control applications present a good opportunity for transferring pulsed power techniques to the commercial sector. However, unless advances are made to drastically reduce the price and power consumption of electron beam sources and pulsed power systems, these plasma techniques will not become commercially competitive with conventional thermal or surface-catalytic methods.

  7. Maximizing Exosome Colloidal Stability Following Electroporation

    PubMed Central

    Hood, Joshua L.; Scott, Michael J.; Wickline, Samuel A.

    2014-01-01

    Development of exosome based semi-synthetic nanovesicles for diagnostic and therapeutic purposes requires novel approaches to load exosomes with cargo. Electroporation has previously been used to load exosomes with RNA. However, investigations into exosome colloidal stability following electroporation have not been considered. Herein, we report the development of a unique trehalose pulse media (TPM) that minimizes exosome aggregation following electroporation. Dynamic light scattering (DLS) and RNA absorbance were employed to determine the extent of exosome aggregation and electroextraction post electroporation in TPM compared to common PBS pulse media or sucrose pulse media (SPM). Use of TPM to disaggregate melanoma exosomes post electroporation was dependent on both exosome concentration and electric field strength. TPM maximized exosome dispersal post electroporation for both homogenous B16 melanoma and heterogeneous human serum derived populations of exosomes. Moreover, TPM enabled heavy cargo loading of melanoma exosomes with 5 nm superparamagnetic iron oxide nanoparticles (SPION5) while maintaining original exosome size and minimizing exosome aggregation as evidenced by transmission electron microscopy. Loading exosomes with SPION5 increased exosome density on sucrose gradients. This provides a simple, label free means to enrich exogenously modified exosomes and introduces the potential for MRI driven theranostic exosome investigations in vivo. PMID:24333249

  8. Maximizing exosome colloidal stability following electroporation.

    PubMed

    Hood, Joshua L; Scott, Michael J; Wickline, Samuel A

    2014-03-01

    Development of exosome-based semisynthetic nanovesicles for diagnostic and therapeutic purposes requires novel approaches to load exosomes with cargo. Electroporation has previously been used to load exosomes with RNA. However, investigations into exosome colloidal stability following electroporation have not been considered. Herein, we report the development of a unique trehalose pulse media (TPM) that minimizes exosome aggregation following electroporation. Dynamic light scattering (DLS) and RNA absorbance were employed to determine the extent of exosome aggregation and electroextraction post electroporation in TPM compared to common PBS pulse media or sucrose pulse media (SPM). Use of TPM to disaggregate melanoma exosomes post electroporation was dependent on both exosome concentration and electric field strength. TPM maximized exosome dispersal post electroporation for both homogenous B16 melanoma and heterogeneous human serum-derived populations of exosomes. Moreover, TPM enabled heavy cargo loading of melanoma exosomes with 5nm superparamagnetic iron oxide nanoparticles (SPION5) while maintaining original exosome size and minimizing exosome aggregation as evidenced by transmission electron microscopy. Loading exosomes with SPION5 increased exosome density on sucrose gradients. This provides a simple, label-free means of enriching exogenously modified exosomes and introduces the potential for MRI-driven theranostic exosome investigations in vivo. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. A differential memristive synapse circuit for on-line learning in neuromorphic computing systems

    NASA Astrophysics Data System (ADS)

    Nair, Manu V.; Muller, Lorenz K.; Indiveri, Giacomo

    2017-12-01

    Spike-based learning with memristive devices in neuromorphic computing architectures typically uses learning circuits that require overlapping pulses from pre- and post-synaptic nodes. This imposes severe constraints on the length of the pulses transmitted in the network, and on the network’s throughput. Furthermore, most of these circuits do not decouple the currents flowing through memristive devices from the one stimulating the target neuron. This can be a problem when using devices with high conductance values, because of the resulting large currents. In this paper, we propose a novel circuit that decouples the current produced by the memristive device from the one used to stimulate the post-synaptic neuron, by using a novel differential scheme based on the Gilbert normalizer circuit. We show how this circuit is useful for reducing the effect of variability in the memristive devices, and how it is ideally suited for spike-based learning mechanisms that do not require overlapping pre- and post-synaptic pulses. We demonstrate the features of the proposed synapse circuit with SPICE simulations, and validate its learning properties with high-level behavioral network simulations which use a stochastic gradient descent learning rule in two benchmark classification tasks.

  10. Latest trends in the assessment and management of paediatric snoring and sleep apnoea.

    PubMed

    Sharma, S D; Kanona, H; Kumar, G; Kotecha, B

    2016-05-01

    To investigate the assessment and management of paediatric snoring and obstructive sleep apnoea in UK otolaryngology departments. A telephone questionnaire survey of UK otolaryngology departments was conducted over a 16-week period. The response rate was 61 per cent (85 out of 139 trusts). Use of pre-operative pulse oximetry was reported by 84 per cent of respondents, mainly to diagnose obstructive sleep apnoea (73 per cent) or stratify post-operative risk (46 per cent). Thirty-one per cent of respondents reported using post-operative pulse oximetry. Twenty-five per cent of respondents have a dedicated management protocol for paediatric obstructive sleep apnoea and snoring. Thirty-four per cent require prior clinical commissioning group approval before performing surgery. Fifty-eight per cent of respondents reported following up their obstructive sleep apnoea patients after surgery. The mean follow-up period (±standard deviation) was 6.8 ± 1.2 weeks. There is variation in the assessment and management of paediatric snoring and obstructive sleep apnoea across the UK, particularly in the use of pre- and post-operative pulse oximetry monitoring, and further guidelines regarding this are necessary.

  11. Combined Yb/Nd driver for optical parametric chirped pulse amplifiers.

    PubMed

    Michailovas, Kirilas; Baltuska, Andrius; Pugzlys, Audrius; Smilgevicius, Valerijus; Michailovas, Andrejus; Zaukevicius, Audrius; Danilevicius, Rokas; Frankinas, Saulius; Rusteika, Nerijus

    2016-09-19

    We report on the developed front-end/pump system for optical parametric chirped pulse amplifiers. The system is based on a dual output fiber oscillator/power amplifier which seeds and assures all-optical synchronization of femtosecond Yb and picosecond Nd laser amplifiers operating at a central wavelength of 1030 nm and 1064 nm, respectively. At the central wavelength of 1030 nm, the fiber oscillator generates partially stretched 4 ps pulses with the spectrum supporting a <120 fs pulse duration and pulse energy of 0.45 nJ. The energy of generated 1064 nm pulses is 0.15 nJ, which is sufficient for the efficient seeding of high-contrast Nd:YVO chirped pulse regenerative amplifier/post amplifier systems generating 9 mJ pulses compressible to 16 ps duration. The power amplification stages, based on Nd:YAG crystals, provide 62 mJ pulses compressible to 20 ps pulse duration at a repetition rate of 1 kHz. Further energy scaling currently is prevented by limited dimensions of the diffraction gratings, which, because of the fast progress in MLD grating manufacturing technologies is only a temporary obstacle.

  12. GEODSS Present Configuration and Potential

    DTIC Science & Technology

    2014-06-28

    to provide critical metric tracking capacity for deep space catalog maintenance. The follow-up TOS designed as a deployable gap filler in SSN deep...CASTOR) - A RAVEN System In Canada [3]WindowPane Observatory Lanphier Shutter System 2014 Retrieved From: http://windowpaneobservatory.com/ [4]J.N

  13. 8. FIRST FLOOR, EAST ROOM, NORTHEAST WALL SHOWING DOORWAYS TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. FIRST FLOOR, EAST ROOM, NORTHEAST WALL SHOWING DOORWAYS TO BOXED WINDER STAIRWAYS, UP ON FAR RIGHT AND DOWN TO RIGHT OF FIREPLACE, WITH SHUTTERS OPEN - High Farm, House, Creek Road, 1 mile West of Easton Road, Pipersville, Bucks County, PA

  14. Photography Foundations: The Student Photojournalist.

    ERIC Educational Resources Information Center

    Glowacki, Joseph W.

    Designed to aid student publications photographers in taking effective photographs, this publication provides discussions relating to the following areas: a publications photographer's self-image, the camera, camera handling, using the adjustable camera, the light meter, depth of field, shutter speeds and action pictures, lenses for publications…

  15. 22. Historic American Buildings Survey, Stanley P. Mixon, Photographer September ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. Historic American Buildings Survey, Stanley P. Mixon, Photographer September 11, 1940 INTERIOR, DETAIL OF END GABLE WINDOW IN ATTIC (SMOKE ROOM) WITH OLD WOODEN SHUTTER, SHOWING PIVOTED SWINGING FRAME. - Fort Zeller, Mill Creek (Millcreek Township), Newmanstown, Lebanon County, PA

  16. CAVE WINDOW

    DOEpatents

    Levenson, M.

    1960-10-25

    A cave window is described. It is constructed of thick glass panes arranged so that interior panes have smaller windowpane areas and exterior panes have larger areas. Exterior panes on the radiation exposure side are remotely replaceable when darkened excessively. Metal shutters minimize exposure time to extend window life.

  17. [Evaluation of Sugar Content of Huanghua Pear on Trees by Visible/Near Infrared Spectroscopy].

    PubMed

    Liu, Hui-jun; Ying, Yi-bin

    2015-11-01

    A method of ambient light correction was proposed to evaluate the sugar content of Huanghua pears on tree by visible/near infrared diffuse reflectance spectroscopy (Vis/NIRS). Due to strong interference of ambient light, it was difficult to collect the efficient spectral of pears on tree. In the field, covering the fruits with a bag blocking ambient light can get better results, but the efficiency is fairly low, the instrument corrections of dark and reference spectra may help to reduce the error of the model, however, the interference of the ambient light cannot be eliminated effectively. In order to reduce the effect of ambient light, a shutter was attached to the front of probe. When opening shutter, the spot spectrum were obtained, on which instrument light and ambient light acted at the same time. While closing shutter, background spectra were obtained, on which only ambient light acted, then the ambient light spectra was subtracted from spot spectra. Prediction models were built using data on tree (before and after ambient light correction) and after harvesting by partial least square (PLS). The results of the correlation coefficient (R) are 0.1, 0.69, 0.924; the root mean square error of prediction (SEP) are 0. 89°Brix, 0.42°Brix, 0.27°Brix; ratio of standard deviation (SD) to SEP (RPD) are 0.79, 1.69, 2.58, respectively. The results indicate that, method of background correction used in the experiment can reduce the effect of ambient lighting on spectral acquisition of Huanghua pears in field, efficiently. This method can be used to collect the visible/near infrared spectrum of fruits in field, and may give full play to visible/near-infrared spectroscopy in preharvest management and maturity testing of fruits in the field.

  18. Photoswitching of ferroelectric liquid crystals using chiral thioindigo dopants: The development of a photochemical switch hitter.

    PubMed

    Lemieux, Robert P

    2004-01-01

    By virtue of its spontaneous polarization (PS), a ferroelectric SmC* liquid crystal can be switched between two states corresponding to opposite molecular tilt orientations using an electric field, thus producing an ON-OFF light shutter between crossed polarizers. Considerable efforts have been made over the past decade to develop photonic FLC light shutters because of their potential uses in dynamic holography and optical data storage. The ON-OFF switching of a FLC light shutter can be triggered by light via a photoinversion of PS using a photochromic dopant. The spontaneous polarization is a chiral bulk property that can be left-handed (negative) or right-handed (positive), depending on the absolute configuration of the chiral component of the SmC* phase. In the approach described herein, the magnitude of PS is modulated via the photoisomerization of a chiral thioindigo dopant that undergoes a large increase in transverse dipole moment upon trans-cis photoisomerization. The sign of PS is photoinverted using an "ambidextrous" thioindigo dopant containing a chiral 2-octyloxy side chain that is coupled to the thioindigo core and induces a positive PS, and a chiral 2,3-difluorooctyloxy side chain that is decoupled from the core and induces a negative PS. In the trans form, the 2,3-difluorooctyloxy side chain predominates and the net PS induced by the dopant is negative. However, upon trans-cis-photoisomerization, the increase in transverse dipole moment of the 2-octyloxy/thioindigo unit raises its induced PS over that of the decoupled 2,3-difluorooctyloxy side chain, and thus inverts the net sign of PS induced by the dopant from negative to positive. Copyright 2004 The Japan Chemical Journal Forum and Wiley Periodicals, Inc.

  19. Apparatuses and methods for laser reading of thermoluminescent phosphors

    DOEpatents

    Braunlich, Peter F.; Tetzlaff, Wolfgang

    1989-01-01

    Apparatuses and methods for rapidly reading thermoluminescent phosphors to determine the amount of luminescent energy stored therein. The stored luminescent energy is interpreted as a measure of the total exposure of the thermoluminescent phosphor to ionizing radiation. The thermoluminescent phosphor reading apparatus uses a laser to generate a laser beam. The laser beam power level is monitored by a laser power detector and controlled to maintain the power level at a desired value or values which can vary with time. A shutter or other laser beam interrupting means is used to control exposure of the thermoluminescent phosphor to the laser beam. The laser beam can be equalized using an opitcal equalizer so that the laser beam has an approximately uniform power density across the beam. The heated thermoluminescent phosphor emits a visible or otherwise detectable luminescent emission which is measured as an indication of the radiation exposure of the thermoluminscent phosphors. Also disclosed are preferred signal processing and control circuits including one system using a digital computer. Also disclosed are time-profiled laser power cycles for pre-anneal, read and post-anneal treatment of phosphors.

  20. A virtual reality oriented clinical experiment on post-stroke rehabilitation: performance and preference comparison among different stereoscopic displays­

    NASA Astrophysics Data System (ADS)

    Yeh, Shih-Ching; Rizzo, Albert; Sawchuk, Alexander A.

    2007-02-01

    We have developed a novel VR task: the Dynamic Reaching Test, that measures human forearm movement in 3D space. In this task, three different stereoscopic displays: autostereoscopic (AS), shutter glasses (SG) and head mounted display (HMD), are used in tests in which subjects must catch a virtual ball thrown at them. Parameters such as percentage of successful catches, movement efficiency (subject path length compared to minimal path length), and reaction time are measured to evaluate differences in 3D perception among the three stereoscopic displays. The SG produces the highest percentage of successful catches, though the difference between the three displays is small, implying that users can perform the VR task with any of the displays. The SG and HMD produced the best movement efficiency, while the AS was slightly less efficient. Finally, the AS and HMD produced similar reaction times that were slightly higher (by 0.1 s) than the SG. We conclude that SG and HMD displays were the most effective, but only slightly better than the AS display.

  1. 9. FIRST FLOOR, EAST ROOM, NORTHEAST WALL, SHOWING DOORWAYS TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. FIRST FLOOR, EAST ROOM, NORTHEAST WALL, SHOWING DOORWAYS TO BOXED WINDER STAIRWAYS, UP ON FAR RIGHT AND DOWN TO RIGHT OF FIREPLACE, WITH SHUTTERS OVER FIREPLACE CLOSED - High Farm, House, Creek Road, 1 mile West of Easton Road, Pipersville, Bucks County, PA

  2. Laser beam control device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, H.L.

    1976-01-06

    The shutter and beam expander for diverting the output of a high power laser into an absorption body comprises a onepiece metallic structure having a convex spherically shaped portion adapted to be moved into the beam path for simultaneously reflecting and expanding the beam into energy absorption material.

  3. Guidebook to School Publications Photography.

    ERIC Educational Resources Information Center

    Glowacki, Joseph W.

    This guidebook for school publications photographers discusses both the self-image of the publications photographer and various aspects of photography, including components of the camera, shutter speed and action pictures, light meters, handling cameras, lenses, developing film, pushing film beyond the emulsion-speed rating recommended by the…

  4. Sustaining Green School Momentum

    ERIC Educational Resources Information Center

    Kennedy, Mike

    2012-01-01

    For several years, schools and universities have been battered by a sputtering economy that on many campuses has brought about slashed budgets, curtailed programs, shuttered facilities and terminated employees. But throughout the gloomy financial conditions, one of the bright spots for education institutions is the continued growing embrace of…

  5. 3. Historic American Buildings Survey James F. and Jean B. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Historic American Buildings Survey James F. and Jean B. O'Gorman, Photographers October 1963 ORIGINAL MANTELPIECE AND WINDOW SHUTTERS, FIRST FLOOR Gift of James F. and Jean B. O'Gorman - Stephen Higginson Jr. House, 7 Kirkland Street, Cambridge, Middlesex County, MA

  6. Switching Matrix For Optical Signals

    NASA Technical Reports Server (NTRS)

    Grove, Charles H.

    1990-01-01

    Proposed matrix of electronically controlled shutters switches signals in optical fibers between multiple input and output channels. Size, weight, and power consumption reduced. Device serves as building block for small, low-power, broad-band television- and data-signal-switching systems providing high isolation between nominally disconnected channels.

  7. Data Processing for the Space-Based Desis Hyperspectral Sensor

    NASA Astrophysics Data System (ADS)

    Carmona, E.; Avbelj, J.; Alonso, K.; Bachmann, M.; Cerra, D.; Eckardt, A.; Gerasch, B.; Graham, L.; Günther, B.; Heiden, U.; Kerr, G.; Knodt, U.; Krutz, D.; Krawcyk, H.; Makarau, A.; Miller, R.; Müller, R.; Perkins, R.; Walter, I.

    2017-05-01

    The German Aerospace Center (DLR) and Teledyne Brown Engineering (TBE) have established a collaboration to develop and operate a new space-based hyperspectral sensor, the DLR Earth Sensing Imaging Spectrometer (DESIS). DESIS will provide spacebased hyperspectral data in the VNIR with high spectral resolution and near-global coverage. While TBE provides the platform and infrastructure for operation of the DESIS instrument on the International Space Station, DLR is responsible for providing the instrument and the processing software. The DESIS instrument is equipped with novel characteristics for an imaging spectrometer such high spectral resolution (2.55 nm), a mirror pointing unit or a CMOS sensor operated in rolling shutter mode. We present here an overview of the DESIS instrument and its processing chain, emphasizing the effect of the novel characteristics of DESIS in the data processing and final data products. Furthermore, we analyse in more detail the effect of the rolling shutter on the DESIS data and possible mitigation/correction strategies.

  8. The optimal code searching method with an improved criterion of coded exposure for remote sensing image restoration

    NASA Astrophysics Data System (ADS)

    He, Lirong; Cui, Guangmang; Feng, Huajun; Xu, Zhihai; Li, Qi; Chen, Yueting

    2015-03-01

    Coded exposure photography makes the motion de-blurring a well-posed problem. The integration pattern of light is modulated using the method of coded exposure by opening and closing the shutter within the exposure time, changing the traditional shutter frequency spectrum into a wider frequency band in order to preserve more image information in frequency domain. The searching method of optimal code is significant for coded exposure. In this paper, an improved criterion of the optimal code searching is proposed by analyzing relationship between code length and the number of ones in the code, considering the noise effect on code selection with the affine noise model. Then the optimal code is obtained utilizing the method of genetic searching algorithm based on the proposed selection criterion. Experimental results show that the time consuming of searching optimal code decreases with the presented method. The restoration image is obtained with better subjective experience and superior objective evaluation values.

  9. Measuring frequency of one-dimensional vibration with video camera using electronic rolling shutter

    NASA Astrophysics Data System (ADS)

    Zhao, Yipeng; Liu, Jinyue; Guo, Shijie; Li, Tiejun

    2018-04-01

    Cameras offer a unique capability of collecting high density spatial data from a distant scene of interest. They can be employed as remote monitoring or inspection sensors to measure vibrating objects because of their commonplace availability, simplicity, and potentially low cost. A defect of vibrating measurement with the camera is to process the massive data generated by camera. In order to reduce the data collected from the camera, the camera using electronic rolling shutter (ERS) is applied to measure the frequency of one-dimensional vibration, whose frequency is much higher than the speed of the camera. Every row in the image captured by the ERS camera records the vibrating displacement at different times. Those displacements that form the vibration could be extracted by local analysis with sliding windows. This methodology is demonstrated on vibrating structures, a cantilever beam, and an air compressor to identify the validity of the proposed algorithm. Suggestions for applications of this methodology and challenges in real-world implementation are given at last.

  10. Tachistoscopic exposure and masking of real three-dimensional scenes

    PubMed Central

    Pothier, Stephen; Philbeck, John; Chichka, David; Gajewski, Daniel A.

    2010-01-01

    Although there are many well-known forms of visual cues specifying absolute and relative distance, little is known about how visual space perception develops at small temporal scales. How much time does the visual system require to extract the information in the various absolute and relative distance cues? In this article, we describe a system that may be used to address this issue by presenting brief exposures of real, three-dimensional scenes, followed by a masking stimulus. The system is composed of an electronic shutter (a liquid crystal smart window) for exposing the stimulus scene, and a liquid crystal projector coupled with an electromechanical shutter for presenting the masking stimulus. This system can be used in both full- and reduced-cue viewing conditions, under monocular and binocular viewing, and at distances limited only by the testing space. We describe a configuration that may be used for studying the microgenesis of visual space perception in the context of visually directed walking. PMID:19182129

  11. Laser additive manufacturing of 3D meshes for optical applications.

    PubMed

    Essa, Khamis; Sabouri, Aydin; Butt, Haider; Basuny, Fawzia Hamed; Ghazy, Mootaz; El-Sayed, Mahmoud Ahmed

    2018-01-01

    Selective laser melting (SLM) is a widely used additive manufacturing process that can be used for printing of intricate three dimensional (3D) metallic structures. Here we demonstrate the fabrication of titanium alloy Ti-6Al-4V alloy based 3D meshes with nodally-connected diamond like unit cells, with lattice spacing varying from 400 to 1000 microns. A Concept Laser M2 system equipped with laser that has a wavelength of 1075 nm, a constant beam spot size of 50μm and maximum power of 400W was used to manufacture the 3D meshes. These meshes act as optical shutters / directional transmitters and display interesting optical properties. A detailed optical characterisation was carried out and it was found that these structures can be optimised to act as scalable rotational shutters with high efficiencies and as angle selective transmission screens for protection against unwanted and dangerous radiations. The efficiency of fabricated lattice structures can be increased by enlarging the meshing size.

  12. Laser additive manufacturing of 3D meshes for optical applications

    PubMed Central

    Essa, Khamis; Sabouri, Aydin; Butt, Haider; Basuny, Fawzia Hamed; Ghazy, Mootaz

    2018-01-01

    Selective laser melting (SLM) is a widely used additive manufacturing process that can be used for printing of intricate three dimensional (3D) metallic structures. Here we demonstrate the fabrication of titanium alloy Ti–6Al–4V alloy based 3D meshes with nodally-connected diamond like unit cells, with lattice spacing varying from 400 to 1000 microns. A Concept Laser M2 system equipped with laser that has a wavelength of 1075 nm, a constant beam spot size of 50μm and maximum power of 400W was used to manufacture the 3D meshes. These meshes act as optical shutters / directional transmitters and display interesting optical properties. A detailed optical characterisation was carried out and it was found that these structures can be optimised to act as scalable rotational shutters with high efficiencies and as angle selective transmission screens for protection against unwanted and dangerous radiations. The efficiency of fabricated lattice structures can be increased by enlarging the meshing size. PMID:29414982

  13. Characteristics of biomass ashes from different materials and their ameliorative effects on acid soils.

    PubMed

    Shi, Renyong; Li, Jiuyu; Jiang, Jun; Mehmood, Khalid; Liu, Yuan; Xu, Renkou; Qian, Wei

    2017-05-01

    The chemical characteristics, element contents, mineral compositions, and the ameliorative effects on acid soils of five biomass ashes from different materials were analyzed. The chemical properties of the ashes varied depending on the source biomass material. An increase in the concrete shuttering contents in the biomass materials led to higher alkalinity, and higher Ca and Mg levels in biomass ashes, which made them particularly good at ameliorating effects on soil acidity. However, heavy metal contents, such as Cr, Cu, and Zn in the ashes, were relatively high. The incorporation of all ashes increased soil pH, exchangeable base cations, and available phosphorus, but decreased soil exchangeable acidity. The application of the ashes from biomass materials with a high concrete shuttering content increased the soil available heavy metal contents. Therefore, the biomass ashes from wood and crop residues with low concrete contents were the better acid soil amendments. Copyright © 2016. Published by Elsevier B.V.

  14. Further Education Colleges and Leadership: Checking the Ethical Pulse

    ERIC Educational Resources Information Center

    Dennis, Carol Azumah

    2016-01-01

    In this paper, I check the ethical pulse of further education (FE) at the moment of its coming of age. Using a philosophical lens, I select and review post-2010 literature, to argue that FE colleges persist in a diminished form within a learning economy. In response to the managerial onslaught, the sector has adopted an ethics of survival, a…

  15. Low power arcjet thruster pulse ignition

    NASA Technical Reports Server (NTRS)

    Sarmiento, Charles J.; Gruber, Robert P.

    1987-01-01

    An investigation of the pulse ignition characteristics of a 1 kW class arcjet using an inductive energy storage pulse generator with a pulse width modulated power converter identified several thruster and pulse generator parameters that influence breakdown voltage including pulse generator rate of voltage rise. This work was conducted with an arcjet tested on hydrogen-nitrogen gas mixtures to simulate fully decomposed hydrazine. Over all ranges of thruster and pulser parameters investigated, the mean breakdown voltages varied from 1.4 to 2.7 kV. Ignition tests at elevated thruster temperatures under certain conditions revealed occasional breakdowns to thruster voltages higher than the power converter output voltage. These post breakdown discharges sometimes failed to transition to the lower voltage arc discharge mode and the thruster would not ignite. Under the same conditions, a transition to the arc mode would occur for a subsequent pulse and the thruster would ignite. An automated 11 600 cycle starting and transition to steady state test demonstrated ignition on the first pulse and required application of a second pulse only two times to initiate breakdown.

  16. Constraining the Post-Thermal Pulse Mass-Loss History of R Scl with SOFIA/FORCAST

    NASA Astrophysics Data System (ADS)

    Hankins, Matthew; Herter, Terry; maercker, matthias; Lau, Ryan M.; Sloan, Greg

    2018-06-01

    R Sculptoris (R Scl) is a nearby (~370 pc) carbon star with a massive circumstellar shell (Mshell∼7×10‑3 M⊙) which is thought to have been produced by a thermal pulse event ∼2200 years ago. We observed R Scl with the Faint Object InfraRed CAMera for the SOFIA Telescope (FORCAST) at 19.7, 25.2, 31.5, 34.8, and 37.1 μm to study its circumstellar dust emission. Maps of the infrared emission were used to examine the morphology and temperature structure of the spatially extended dust emission. We used the radiative transfer code DUSTY to fit the radial density profile of the circumstellar material, and find that a geometrically thin dust shell cannot reproduce the observed emission. Instead, a second dust component is needed to model the emission. This component, which lies interior to the dust shell, traces the post-thermal pulse mass loss of R Scl and is indicative of a slow decline in the star’s mass loss over thousands of years. This result is at odds with 'classical' thermal pulse models but is consistent with earlier observations of molecular gas in R Scl’s circumstellar environment.

  17. Recent advances in Reltron and Super-Reltron HPM source development

    NASA Astrophysics Data System (ADS)

    Miller, Robert B.; Muehlenweg, Carl A.; Habiger, Kerry W.; Smith, John R.; Shiffler, Donald A.

    1994-05-01

    Reltron and super-reltron microwave tubes use post acceleration of a well-modulated beam and multiple output cavity extraction sections to generate high power microwave pulses with excellent efficiency. We have continued our development of these tubes with emphasis being given to four specific topics: (1) Recent experiments with our 1-GHz super-reltron tube have demonstrated operation at a peak power level of 600 MW. With pulse durations of several hundred nanoseconds, the microwave energy per pulse is about 250 J. (2) We have extracted significant power (several tens of megawatts) at the third multiple (3 GHz) of our 1-GHz super-reltron tube using output cavities designed for operation in S-band. (3) We have fielded a small S-band super-reltron tube on our 260 kV modulator. We have obtained lifetime data for this tube under repetitive (20 Hz), long pulse (2 microsecond(s) ec) operating conditions. (4) We have initiated feasibility experiments of the reltron concept by post accelerating the bunched beam produced by a SLAC XK-5 klystron. In this paper we report our experimental results and discuss relevant theoretical considerations related to each of these four topics.

  18. Real-Time, Digital Pulse-Shape Discrimination in Non-Hazardous Fast Liquid Scintillation Detectors: Prospects for Safety and Security

    NASA Astrophysics Data System (ADS)

    Joyce, Malcolm J.; Aspinall, Michael D.; Cave, Francis D.; Lavietes, Anthony D.

    2012-08-01

    Pulse-shape discrimination (PSD) in fast, organic scintillation detectors is a long-established technique used to separate neutrons and γ rays in mixed radiation fields. In the analogue domain the method can achieve separation in real time, but all knowledge of the pulses themselves is lost thereby preventing the possibility of any post- or repeated analysis. Also, it is typically reliant on electronic systems that are largely obsolete and which require significant experience to set up. In the digital domain, PSD is often more flexible but significant post-processing has usually been necessary to obtain neutron/γ-ray separation. Moreover, the scintillation media on which the technique relies usually have a low flashpoint and are thus deemed hazardous. This complicates the ease with which they are used in industrial applications. In this paper, results obtained with a new portable digital pulse-shape discrimination instrument are described. This instrument provides real-time, digital neutron/γ-ray separation whilst preserving the synchronization with the time-of-arrival for each event, and realizing throughputs of 3 × 106 events per second. Furthermore, this system has been tested with a scintillation medium that is non-flammable and not hazardous.

  19. A Long-term study of three rotating radio transients

    NASA Astrophysics Data System (ADS)

    Bhattacharyya, B.; Lyne, A. G.; Stappers, B. W.; Weltevrede, P.; Keane, E. F.; McLaughlin, M. A.; Kramer, M.; Jordan, C.; Bassa, C.

    2018-04-01

    We present the longest-term timing study so far of three Rotating Radio Transients (RRATs) - J1819-1458, J1840-1419 and J1913+1330 - performed using the Lovell, Parkes and Green Bank telescopes over the past decade. We study long-term and short-term variations of the pulse emission rate from these RRATs and report a marginal indication of a long-term increase in pulse detection rate over time for PSR J1819-1458 and J1913+1330. For PSR J1913+1330, we also observe a two orders of magnitude variation in the observed pulse detection rates across individual epochs, which may constrain the models explaining the origin of RRAT pulses. PSR J1913+1330 is also observed to exhibit a weak persistent emission mode. We investigate the post-glitch timing properties of J1819-1458 (the only RRAT for which glitches are observed) and discuss the implications for possible glitch models. Its post-glitch over-recovery of the frequency derivative is magnetar-like and similar behaviour is only observed for two other pulsars, both of which have relatively high magnetic field strengths. Following the over-recovery we also observe that some fraction of the pre-glitch frequency derivative is gradually recovered.

  20. Pulsed-Current Electrochemical Codeposition and Heat Treatment of Ti-Dispersed Ni-Matrix Layers

    NASA Astrophysics Data System (ADS)

    Janetaisong, Pathompong; Boonyongmaneerat, Yuttanant; Techapiesancharoenkij, Ratchatee

    2016-08-01

    An electrochemical deposition is a fast and cost-efficient process to produce film or coating. In this research, Ni-Ti electrodeposition is developed by codepositing a Ti-dispersed Ni-matrix layer from a Ni-plating solution suspended with Ti particles. To enhance the coating uniformity and control the atomic composition, the pulsed current was applied to codeposit Ni-Ti layers with varying pulse duty cycles (10 to 100 pct) and frequencies (10 to 100 Hz). The microstructures and compositions of the codeposited layers were analyzed by scanning electron microscopy, X-ray diffraction, and X-ray fluorescent techniques. The pulsed current significantly improved the quality of the Ni-Ti layer as compared to a direct current. The Ni-Ti layers could be electroplated with a controlled composition within 48 to 51 at. pct of Ti. The optimal pulse duty cycle and frequency are 50 pct and 10 Hz, respectively. The standalone Ni-49Ti layers were removed from copper substrates by selective etching method and subsequently heat-treated under Ar-fed atmosphere at 1423 K (1150 °C) for 5 hours. The phase and microstructures of the post-annealed samples exhibit different Ni-Ti intermetallic compounds, including NiTi, Ni3Ti, and NiTi2. Yet, the contamination of TiN and TiO2 was also present in the post-annealed samples.

  1. Fast kinetic studies of plasmid DNA transfer in intact yeast cells mediated by electropulsation.

    PubMed

    Ganeva, V; Galutzov, B; Teissie, J

    1995-09-25

    Intact yeast cell Electrotransformation process was investigated. It is a two step process. The plasmid must be pre-mixed and present in contact with the cells during the pulse. During the millisecond field pulse, plasmid DNA is associated to the envelope. It therefore crosses the membrane by a process which lasts several seconds as shown by its sensitivity to a post pulse addition of DNase. Electrotransformation is not supported by an electrophoretic transfer due to the external field nor by a free diffusion across the electropermeabilized envelope. DNA is first bound during the field pulse and then is transferred by a still unknown active process due to cell metabolism.

  2. Nd:YAG development for spaceborne laser ranging system

    NASA Technical Reports Server (NTRS)

    Harper, L. L.; Logan, K. E.; Williams, R. H.; Stevens, D. A.

    1979-01-01

    The results of the development of a unique modelocked laser device to be utilized in future NASA space-based, ultraprecision laser ranger systems are summarized. The engineering breadboard constructed proved the feasibility of the pump-pulsed, actively modelocked, PTM Q-switched Nd:YAG laser concept for the generation of subnanosecond pulses suitable for ultra-precision ranging. The laser breadboard also included a double-pass Nd:YAG amplifier and provision for a Type II KD*P frequency doubler. The specific technical accomplishment was the generation of single 150 psec, 20-mJ pulses at 10 pps at a wavelength of 1.064 micrometers with 25 dB suppression of pre-and post-pulses.

  3. The effects of electromagnetic pulse on the protein levels of tight junction associated-proteins in the cerebral cortex, hippocampus, heart, lung, and testis of rats.

    PubMed

    Qiu, LianBo; Chen, Chen; Ding, GuiRong; Zhou, Yan; Zhang, MengYao

    2011-08-01

    To investigate changes in the expression of tight junction (TJ) proteins in the cerebral cortex, hippocampus, heart, lung, and testes of rats after exposure to electromagnetic pulse (EMP). Eighteen adult male Sprague-Dawley rats were divided into sham and exposure groups. The exposure groups received EMP at 200 kV/m for 200 pulses with a repetition rate of 1 Hz. The expression of TJ proteins (ZO-1, occludin, actin) in the several organs was examined by western blotting. ZO-1 levels in the cerebral cortex decreased 1 h and 3 h after EMP exposure compared with sham group (P<0.05). No significant difference was observed for occludin and actin. ZO-1 levels in the hippocampus increased 1 h and 3 h post-exposure (P<0.05), and occludin decreased after 3 h (P<0.05); however, actin was unaffected. ZO-1 levels in the heart increased 3 h post-exposure (P<0.05), occludin decreased 3 h post-exposure (P<0.05), and actin increased 1 h and 3 h post-exposure (P<0.05). ZO-1, occludin and actin levels in the lung decreased compared with those in the sham group (P<0.05). ZO-1 and occludin levels in the testes decreased 1 h and 3 h post-exposure (P<0.05), but actin showed no significant change. Exposure to EMP altered the expression levels of TJ proteins, particularly ZO-1, in the organs of adult male rats, which may induce changes in barrier structure and function. Copyright © 2011 The Editorial Board of Biomedical and Environmental Sciences. Published by Elsevier B.V. All rights reserved.

  4. Full-field wrist pulse signal acquisition and analysis by 3D Digital Image Correlation

    NASA Astrophysics Data System (ADS)

    Xue, Yuan; Su, Yong; Zhang, Chi; Xu, Xiaohai; Gao, Zeren; Wu, Shangquan; Zhang, Qingchuan; Wu, Xiaoping

    2017-11-01

    Pulse diagnosis is an essential part in four basic diagnostic methods (inspection, listening, inquiring and palpation) in traditional Chinese medicine, which depends on longtime training and rich experience, so computerized pulse acquisition has been proposed and studied to ensure the objectivity. To imitate the process that doctors using three fingertips with different pressures to feel fluctuations in certain areas containing three acupoints, we established a five dimensional pulse signal acquisition system adopting a non-contacting optical metrology method, 3D digital image correlation, to record the full-field displacements of skin fluctuations under different pressures. The system realizes real-time full-field vibration mode observation with 10 FPS. The maximum sample frequency is 472 Hz for detailed post-processing. After acquisition, the signals are analyzed according to the amplitude, pressure, and pulse wave velocity. The proposed system provides a novel optical approach for digitalizing pulse diagnosis and massive pulse signal data acquisition for various types of patients.

  5. Carotid artery stiffness evaluated early by wave intensity in normal left ventricular function in post-radiotherapy patients with nasopharyngeal carcinoma.

    PubMed

    Zhang, Zhuo; Luo, Runlan; Tan, Bijun; Qian, Jing; Duan, Yanfang; Wang, Nan; Li, Guangsen

    2018-04-01

    This study aims to assess carotid elasticity early in normal left ventricular function in post-radiotherapy patients with nasopharyngeal carcinoma (NPC) by wave intensity. Sixty-seven post-radiotherapy patients all with normal left ventricular function were classified into group NPC1 and group NPC2 based on their carotid intima-media thickness. Thirty age- and sex-matched NPC patients without any history of irradiation and chemotherapy were included as a control group. Carotid parameters, including stiffness constant (β), pressure-strain elastic modulus (Ep), arterial compliance (AC), stiffness constant pulse wave velocity (PWVβ), and wave intensity pulse wave velocity (PWVWI) were measured. There were no significant differences in conventional echocardiographic variables among the three groups. In comparison with the control group, β, Ep, PWVβ, and PWVWI were significantly increased, while AC was significantly decreased in the NPC1 and NPC2 groups, and there were differences between the NPC1 group and NPC2 group (all P < 0.05). This study suggested that carotid artery stiffness increased with reduced carotid compliance in post-RT with NPC.

  6. Comparative study of dual-pulsed 1064 nm Q-switched Nd:YAG laser and single-pulsed 1064 nm Q-switched Nd:YAG laser by using zebrafish model and prospective split-face analysis of facial melasma.

    PubMed

    Jang, Hee Won; Chun, Seung Hyun; Park, Hae Chul; Ryu, Hwa Jung; Kim, Il-Hwan

    2017-04-01

    Recently dual-pulsed low-fluence 1064-nm Q-switched Nd:YAG (QSNY) laser has been developed for reducing complication during melasma treatment. Comparison of the efficacy and safety between dual-pulsed mode and single-pulsed mode for the treatment of melasma. In preclinical study, adult zebrafish were irradiated with dual-pulsed and single-pulsed mode. Changes of melanophore and cell death were assessed. In split-face clinical study, dual-pulsed and single-pulsed mode were irradiated on the left and right side of the face, respectively. L* value, clinical digital photos, modified Melasma Area and Severity Index (MASI) scores, and side effects were measured. As compared to single-pulsed mode and dual-pulsed mode with longer intervals, zebrafish melanophore was cleared quickly at dual-pulsed mode with 80-μsec interval and 0.3 J/cm 2 fluence. Dual-pulsed mode showed the least regeneration of melanophore at 4 weeks after irradiation and no cell death was observed with 80-μsec interval. Both pulse modes improved melasma significantly but modified MASI score and L* value were not significantly different between each other. Lesser pain and shorter duration of post-laser erythema were observed with dual-pulsed mode. Dual-pulsed mode was as effective as single-pulsed mode for the treatment of melasma and revealed less side effects.

  7. Nitrogen leaching following whole-tree and bole-only harvests on two contrasting Pacific Northwest sites

    Treesearch

    Warren D. Devine; Paul W. Footen; Brian D. Strahm; Robert B. Harrison; Thomas A. Terry; Timothy B. Harrington

    2012-01-01

    Short-term pulses of increased N leaching typically follow the harvest of forest stands, but the magnitude of these pulses after conventional bole-only (BO) and whole-tree (WT) harvests often is difficult to predict. In this study, we measured N leaching until 6 and 8 years post-harvest on two western Washington Douglas-fir (Pseudotsuga menziesii...

  8. A dual-beam actinic light source for photosynthesis research

    NASA Technical Reports Server (NTRS)

    Margozzi, A. P.; Henderson, M. E.

    1972-01-01

    Simulation of photosynthetic process in plants is accomplished by using two separate and identical optical channels that provide independently adjustable wavelengths (filters), shutter sequencing, and control intensity of illumination. In addition to experiments using electron paramagnetic resonance spectroscopy, system may be applicable to other types of research in photosynthetic field.

  9. 46 CFR 45.117 - Freeing port area: General.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LOAD LINES GREAT LAKES LOAD LINES... on the freeboard deck and on the raised quarterdeck must be at least as great as A in the following... bearings of noncorrodible material. If shutters are fitted with securing appliances, these appliances must...

  10. 46 CFR 45.117 - Freeing port area: General.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LOAD LINES GREAT LAKES LOAD LINES... on the freeboard deck and on the raised quarterdeck must be at least as great as A in the following... bearings of noncorrodible material. If shutters are fitted with securing appliances, these appliances must...

  11. 46 CFR 45.117 - Freeing port area: General.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LOAD LINES GREAT LAKES LOAD LINES... on the freeboard deck and on the raised quarterdeck must be at least as great as A in the following... bearings of noncorrodible material. If shutters are fitted with securing appliances, these appliances must...

  12. 46 CFR 45.117 - Freeing port area: General.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LOAD LINES GREAT LAKES LOAD LINES... on the freeboard deck and on the raised quarterdeck must be at least as great as A in the following... bearings of noncorrodible material. If shutters are fitted with securing appliances, these appliances must...

  13. 46 CFR 45.117 - Freeing port area: General.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LOAD LINES GREAT LAKES LOAD LINES... on the freeboard deck and on the raised quarterdeck must be at least as great as A in the following... bearings of noncorrodible material. If shutters are fitted with securing appliances, these appliances must...

  14. A House Divided

    ERIC Educational Resources Information Center

    Carlson, Scott

    2007-01-01

    This article discusses Antioch College, a once-prominent countercultural institution that will be closed in 2008 due to serious financial problems. Antioch has been hemorrhaging money for years. Its Board of Trustees has decided to shutter the college by July 2008 and lay off most of its 160 staff and faculty members. Although the administration…

  15. Schools in the New Economy

    ERIC Educational Resources Information Center

    Kennedy, Mike

    2011-01-01

    Schools and universities across the United States have been forced to cope with a grim financial situation that has left them without adequate resources. Administrators are cutting programs, reining in salaries and jettisoning employees to keep operating budgets in line. Education institutions also have had to shutter facilities or postpone,…

  16. 14 CFR 27.1305 - Powerplant instruments.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... with § 27.955. (n) A gas temperature indicator for each turbine engine. (o) Means to enable the pilot... temperature indicator, for each— (1) Air cooled engine; (2) Rotorcraft with cooling shutters; and (3... condition with respect to cooling. (c) A fuel pressure indicator, for each pump-fed engine. (d) A fuel...

  17. 14 CFR 27.1305 - Powerplant instruments.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... with § 27.955. (n) A gas temperature indicator for each turbine engine. (o) Means to enable the pilot... temperature indicator, for each— (1) Air cooled engine; (2) Rotorcraft with cooling shutters; and (3... condition with respect to cooling. (c) A fuel pressure indicator, for each pump-fed engine. (d) A fuel...

  18. 14 CFR 27.1305 - Powerplant instruments.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... with § 27.955. (n) A gas temperature indicator for each turbine engine. (o) Means to enable the pilot... temperature indicator, for each— (1) Air cooled engine; (2) Rotorcraft with cooling shutters; and (3... condition with respect to cooling. (c) A fuel pressure indicator, for each pump-fed engine. (d) A fuel...

  19. 14 CFR 27.1305 - Powerplant instruments.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... with § 27.955. (n) A gas temperature indicator for each turbine engine. (o) Means to enable the pilot... temperature indicator, for each— (1) Air cooled engine; (2) Rotorcraft with cooling shutters; and (3... condition with respect to cooling. (c) A fuel pressure indicator, for each pump-fed engine. (d) A fuel...

  20. Direct generation of all-optical random numbers from optical pulse amplitude chaos.

    PubMed

    Li, Pu; Wang, Yun-Cai; Wang, An-Bang; Yang, Ling-Zhen; Zhang, Ming-Jiang; Zhang, Jian-Zhong

    2012-02-13

    We propose and theoretically demonstrate an all-optical method for directly generating all-optical random numbers from pulse amplitude chaos produced by a mode-locked fiber ring laser. Under an appropriate pump intensity, the mode-locked laser can experience a quasi-periodic route to chaos. Such a chaos consists of a stream of pulses with a fixed repetition frequency but random intensities. In this method, we do not require sampling procedure and external triggered clocks but directly quantize the chaotic pulses stream into random number sequence via an all-optical flip-flop. Moreover, our simulation results show that the pulse amplitude chaos has no periodicity and possesses a highly symmetric distribution of amplitude. Thus, in theory, the obtained random number sequence without post-processing has a high-quality randomness verified by industry-standard statistical tests.

  1. Note: A rectangular pulse generator for 50 kV voltage, 0.8 ns rise time, and 10 ns pulse width based on polymer-film switch.

    PubMed

    Wu, Hanyu; Zhang, Xinjun; Sun, Tieping; Zeng, Zhengzhong; Cong, Peitian; Zhang, Shaoguo

    2015-10-01

    In this article, we describe a rectangular pulse generator, consisting of a polymer-film switch, a tri-plate transmission line, and parallel post-shaped ceramic resistor load, for 50-kV voltage, 0.8-ns rise time, and 10-ns width. The switch and resistors are arranged in atmospheric air and the transmission line can work in atmospheric air or in transformer oil to change the pulse width from 6.7 ns to 10 ns. The fast switching and low-inductance characteristics of the polymer-film switch ensure the fast rising wavefront of <1 ns. This generator can be applied in the calibration of nanosecond voltage dividers and used for electromagnetic pulse tests as a fast-rising current injection source.

  2. Correction factor for ablation algorithms used in corneal refractive surgery with gaussian-profile beams

    NASA Astrophysics Data System (ADS)

    Jimenez, Jose Ramón; González Anera, Rosario; Jiménez del Barco, Luis; Hita, Enrique; Pérez-Ocón, Francisco

    2005-01-01

    We provide a correction factor to be added in ablation algorithms when a Gaussian beam is used in photorefractive laser surgery. This factor, which quantifies the effect of pulse overlapping, depends on beam radius and spot size. We also deduce the expected post-surgical corneal radius and asphericity when considering this factor. Data on 141 eyes operated on LASIK (laser in situ keratomileusis) with a Gaussian profile show that the discrepancy between experimental and expected data on corneal power is significantly lower when using the correction factor. For an effective improvement of post-surgical visual quality, this factor should be applied in ablation algorithms that do not consider the effects of pulse overlapping with a Gaussian beam.

  3. Plasma Membrane Permeabilization by Trains of Ultrashort Electric Pulses

    PubMed Central

    Ibey, Bennett L.; Mixon, Dustin G.; Payne, Jason A.; Bowman, Angela; Sickendick, Karl; Wilmink, Gerald J.; Roach, W. Patrick; Pakhomov, Andrei G.

    2010-01-01

    Ultrashort electric pulses (USEP) cause long-lasting increase of cell membrane electrical conductance, and that a single USEP increased cell membrane electrical conductance proportionally to the absorbed dose (AD) with a threshold of about 10 mJ/g. The present study extends quantification of the membrane permeabilization effect to multiple USEP and employed a more accurate protocol that identified USEP effect as the difference between post- and pre-exposure conductance values (Δg) in individual cells. We showed that Δg can be increased by either increasing the number of pulses at a constant E-field, or by increasing the E-field at a constant number of pulses. For 60-ns pulses, an E-field threshold of 6 kV/cm for a single pulse was lowered to less than 1.7 kV/cm by applying 100-pulse or longer trains. However, the reduction of the E-field threshold was only achieved at the expense of a higher AD compared to a single pulse exposure. Furthermore, the effect of multiple pulses was not fully determined by AD, suggesting that cells permeabilized by the first pulse(s) in the train become less vulnerable to subsequent pulses. This explanation was corroborated by a model that treated multiple-pulse exposures as a series of single-pulse exposures and assumed an exponential decline of cell susceptibility to USEP as Δg increased after each pulse during the course of the train. PMID:20171148

  4. TH-CD-201-10: Highly Efficient Synchronized High-Speed Scintillation Camera System for Measuring Proton Range, SOBP and Dose Distributions in a 2D-Plane

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goddu, S; Sun, B; Grantham, K

    2016-06-15

    Purpose: Proton therapy (PT) delivery is complex and extremely dynamic. Therefore, quality assurance testing is vital, but highly time-consuming. We have developed a High-Speed Scintillation-Camera-System (HS-SCS) for simultaneously measuring multiple beam characteristics. Methods: High-speed camera was placed in a light-tight housing and dual-layer neutron shield. HS-SCS is synchronized with a synchrocyclotron to capture individual proton-beam-pulses (PBPs) at ∼504 frames/sec. The PBPs from synchrocyclotron trigger the HS-SCS to open its shutter for programmed exposure-time. Light emissions within 30×30×5cm3 plastic-scintillator (BC-408) were captured by a CCD-camera as individual images revealing dose-deposition in a 2D-plane with a resolution of 0.7mm for range andmore » SOBP measurements and 1.67mm for profiles. The CCD response as well as signal to noise ratio (SNR) was characterized for varying exposure times, gains for different light intensities using a TV-Optoliner system. Software tools were developed to analyze ∼5000 images to extract different beam parameters. Quenching correction-factors were established by comparing scintillation Bragg-Peaks with water scanned ionization-chamber measurements. Quenching corrected Bragg-peaks were integrated to ascertain proton-beam range (PBR), width of Spared-Out-Bragg-Peak (MOD) and distal.« less

  5. Trans advanced surface laser ablation (TransPRK) outcomes using SmartPulseTechnology.

    PubMed

    Aslanides, Ioannis M; Kymionis, George D

    2017-02-01

    To evaluate early visual rehabilitation, post-operative pain, epithelial healing and haze after transepithelial photorefractive keratectomy (TransPRK) using the SmartPulseTechnology (SPT) of Schwind Amaris (Schwind eye-tech-solutions GmbH, Kleinostheim, Germany). This was a retrospective comparative evaluation of a cohort of myopic patients undergoing TransPRK with SPT (group 1), with one matched control group that underwent conventional TransPRK (group 2). All cases had a 6-month post-operative follow-up including visual acuity and slit-lamp examination. Subjective evaluation of pain was recorded post-operatively. 49 eyes of 25 patients in group 1 and 40 eyes of 20 patients in group 2 were enrolled. The patients' visual rehabilitation was significantly faster in group 1, one day and one week post-operatively (P<0.05). From one month onward there was no significant difference between the groups. The epithelial defect size was significantly smaller on post-operative days 1 and 2 for group 1 (P<0.05 in both cases). The pain score was also significantly less in group 1 (P<0.05). The haze level had no significant difference between the groups at any post-operative point (P>0.05). TransPRK using SPT provides promising results in the early post-operative period. Visual rehabilitation, re-epithelialization and pain were faster in the early post-operative period in group 1 in comparison with group 2. Haze formation was not significantly different between the two groups; however, it was consistently less in group 1. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  6. Variable-pulse-shape pulsed-power accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoltzfus, Brian S.; Austin, Kevin; Hutsel, Brian Thomas

    A variable-pulse-shape pulsed-power accelerator is driven by a large number of independent LC drive circuits. Each LC circuit drives one or more coaxial transmission lines that deliver the circuit's output power to several water-insulated radial transmission lines that are connected in parallel at small radius by a water-insulated post-hole convolute. The accelerator can be impedance matched throughout. The coaxial transmission lines are sufficiently long to transit-time isolate the LC drive circuits from the water-insulated transmission lines, which allows each LC drive circuit to be operated without being affected by the other circuits. This enables the creation of any power pulsemore » that can be mathematically described as a time-shifted linear combination of the pulses of the individual LC drive circuits. Therefore, the output power of the convolute can provide a variable pulse shape to a load that can be used for magnetically driven, quasi-isentropic compression experiments and other applications.« less

  7. An experimental vestibular neural prosthesis: design and preliminary results with rhesus monkeys stimulated with modulated pulses.

    PubMed

    Nie, Kaibao; Ling, Leo; Bierer, Steven M; Kaneko, Chris R S; Fuchs, Albert F; Oxford, Trey; Rubinstein, Jay T; Phillips, James O

    2013-06-01

    A vestibular neural prosthesis was designed on the basis of a cochlear implant for treatment of Meniere's disease and other vestibular disorders. Computer control software was developed to generate patterned pulse stimuli for exploring optimal parameters to activate the vestibular nerve. Two rhesus monkeys were implanted with the prototype vestibular prosthesis and they were behaviorally evaluated post implantation surgery. Horizontal and vertical eye movement responses to patterned electrical pulse stimulations were collected on both monkeys. Pulse amplitude modulated (PAM) and pulse rate modulated (PRM) trains were applied to the lateral canal of each implanted animal. Robust slow-phase nystagmus responses following the PAM or PRM modulation pattern were observed in both implanted monkeys in the direction consistent with the activation of the implanted canal. Both PAM and PRM pulse trains can elicit a significant amount of in-phase modulated eye velocity changes and they could potentially be used for efficiently coding head rotational signals in future vestibular neural prostheses.

  8. Femtosecond Electron and Photon Pulses Facility in Thailand

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rimjaem, S.; Thongbai, C.; Jinamoon, V.

    Femtosecond electron and photon pulses facility has been established as SURIYA project at the Fast Neutron Research Facility (FNRF). Femtosecond electron bunches can be generated from a system consisting of an RF gun with a thermionic cathode, an alpha magnet as an magnetic bunch compressor, and a linear accelerator as a post acceleration section. Femtosecond electron pulses can be used directly or used as a source to produce equally short electromagnetic (EM) radiation pulses via certain kind of radiation production processes. At SURIYA project, we are interested especially in production of radiation in Far-infrared (FIR) regime. At these wavelengths, themore » radiation from femtosecond electron pulses is emitted coherently resulting in high intensity radiation. Overview of the facility, the generation of femtosecond electron bunches, the theoretical background of coherent transition radiation and the recent experimental results will be presented and discussed in this paper.« less

  9. Effect of electromagnetic pulse on avoidance behavior and electroencephalogram of a rhesus monkey.

    PubMed

    Mattsson, J L; Oliva, S A

    1976-06-01

    A 12-kg male rhesus monkey was exposed to electromagnetic pulse (EMP) at 266 kv/m, 5 pulses/s, for 1 h (18,700 pulses). The effects of EMP on Sidman avoidance behavior and on post-exposure electroencephalogram were evaluated, and no significant changes were detected. An analysis of an EMP showed that it contained various frequency components extending from 0 Hz to 10(9) Hz. However, the pulse configuration was such that its power was mainly confined to the longer wave-lengths (less than 30 MHz). The lack of biologic effect was attributed to the fact that the wavelengths were long relative to the size of the monkey, and little energy deposition was likely to occur. In addition, the electric field was evenly distributed across all lower frequencies so that only a very small electric field component existed at any specific low frequency.

  10. Rapid amelioration of severe manic episodes with right unilateral ultrabrief pulse ECT: a case series of four patients.

    PubMed

    Sidorov, Alexey; Mayur, Prashanth

    2017-02-01

    The aim of this small case series is to describe four cases of severe mania, where ultrabrief pulse electroconvulsive therapy (ECT) was used as a primary mode of treatment. A retrospective file review was undertaken of four patients identified as having received ultrabrief pulse ECT for severe mania. The outcome measures for treatment efficacy were the Young Mania Rating Scale (YMRS) and Clinical Global Impression (CGI). All the patients showed significant clinical improvement. A comparison of pre- and post-treatment YMRS and CGI scores showed a dramatic decrease in all four cases. However, one patient was shifted to brief pulse ECT due to inadequate response. Ultrabrief pulse ECT may be an effective treatment in cases of severe mania. Due to the very small number of cases in the current case series, no specific conclusions regarding efficacy may be drawn; however, larger, controlled studies would be indicated.

  11. Nekton community response to a large-scale Mississippi River discharge: Examining spatial and temporal response to river management

    USGS Publications Warehouse

    Piazza, Bryan P.; La Peyre, M.K.

    2011-01-01

    Freshwater flow is generally held to be one of the most influential factors affecting community structure and production in estuaries. In coastal Louisiana, the Caernarvon Freshwater Diversion (CFD) is managed to control freshwater discharge from the Mississippi River into Breton Sound basin. Operational since 1991, CFD has undergone several changes in management strategy including pulsed spring flooding, which was introduced in 2001. We used a 20-yr time series of fisheries-independent data to investigate how variation in freshwater inflow (i.e., pre- and post-CFD, and pre and post spring pulsing management) influences the downstream nekton community (abundance, diversity, and assemblage). Analyses of long-term data demonstrated that while there were effects from the CFD, they largely involved subtle changes in community structure. Spatially, effects were largely limited to the sites immediately downstream of the diversion and extended only occasionally to more down-estuary sites. Temporally, effects were 1) immediate (detected during spring diversion events) or 2) delayed (detected several months post-diversion). Analysis of river management found that pulsed spring-time inflow resulted in more significant changes in nekton assemblages, likely due to higher discharge rates that 1) increased marsh flooding, thus increasing marsh habitat accessibility for small resident marsh species, and 2) reduced salinity, possibly causing displacement of marine pelagic species down estuary. ?? 2010.

  12. Apollo 8 Mission image,Earth and Lunar Horizon

    NASA Image and Video Library

    1968-12-21

    Apollo 8,Earth and Lunar Horizon. Image taken on Revolution 10 during Transearth Injection (TEI). Original Film Magazine was labeled D. Camera Data: 70mm Hasselblad. Lens: 80mm; F-Stop: F/11; Shutter Speed: 1/250 second. Film Type: Kodak SO-3400 Black and White,ASA 40. Flight Date: December 21-27,1968.

  13. Hot hollow cathode gun assembly

    DOEpatents

    Zeren, J.D.

    1983-11-22

    A hot hollow cathode deposition gun assembly includes a hollow body having a cylindrical outer surface and an end plate for holding an adjustable heat sink, the hot hollow cathode gun, two magnets for steering the plasma from the gun into a crucible on the heat sink, and a shutter for selectively covering and uncovering the crucible.

  14. Vacuum vapor deposition gun assembly

    DOEpatents

    Zeren, Joseph D.

    1985-01-01

    A vapor deposition gun assembly includes a hollow body having a cylindrical outer surface and an end plate for holding an adjustable heat sink, a hot hollow cathode gun, two magnets for steering the plasma from the gun into a crucible on the heat sink, and a shutter for selectively covering and uncovering the crucible.

  15. Physics on Tap

    ERIC Educational Resources Information Center

    Wheeler, Andrew P. S.

    2012-01-01

    This article aims to describe how to visualize surface tension effects in liquid jets. A simple experiment is proposed using the liquid jet flow from a mains water tap/faucet. Using a modern digital camera with a high shutter speed, it is possible to visualize the instabilities (capillary waves) that form within the jet due to the action of…

  16. Antioch Rises from the Ashes

    ERIC Educational Resources Information Center

    Biemiller, Lawrence

    2012-01-01

    This article features Antioch College, an old campus with a new future. With no tuition, no accreditation, and a mostly empty campus, the college is making a slow and careful start. Reopening a college that had been shuttered for three years certainly qualifies--especially a college with a rich history that, at this point, is equal parts blessing…

  17. An automatic lightning detection and photographic system

    NASA Technical Reports Server (NTRS)

    Wojtasinski, R. J.; Holley, L. D.; Gray, J. L.; Hoover, R. B.

    1973-01-01

    Conventional 35-mm camera is activated by an electronic signal every time lightning strikes in general vicinity. Electronic circuit detects lightning by means of antenna which picks up atmospheric radio disturbances. Camera is equipped with fish-eye lense, automatic shutter advance, and small 24-hour clock to indicate time when exposures are made.

  18. Debates over School Shutdowns Heating Up

    ERIC Educational Resources Information Center

    Zubrzycki, Jaclyn

    2012-01-01

    As school closures are increasingly used as a remedy to budget woes and a solution to failing schools in many cities, debates are intensifying about their effect on student performance and well-being, on district finances, and on communities and the processes districts use to choose which schools will be shuttered. Student and parent groups in…

  19. Basic Photography; A Primer for Professionals. Second Edition.

    ERIC Educational Resources Information Center

    Langford, Michael J.

    In this textbook, which was written for the professional photography student, both photographic theory and practice are thoroughly explained. The author examines the principles of light and the properties of lenses and gives a detailed evaluation of camera movement, camera shutters, and the camera as a whole. He outlines the manufacture and…

  20. Permanent Visual Change Associated with Punctate Foveal Lesions,

    DTIC Science & Technology

    1986-03-01

    Resources, National Research Council. This material has been reviewed by Letterman Army Institute of Research and there is no objection to its presentation...OrIDist swia SPEC, 4 -Zwick et al .4.D DETECTOR MIRROR I DIFFUSER FRONT SURFACE OSLD ND MIRROR LASER SHUTTER 3 REAM No FILTERr-: SPLIT7ER L3 C

  1. Is German Necessary? Nein, Says One University

    ERIC Educational Resources Information Center

    Wasley, Paula

    2008-01-01

    When the University of Southern California announced that it would shutter its tiny German department, the outcry was out of proportion to the handful of faculty members and students directly affected by the move. In addition to students who advertised their dismay on Facebook and faculty members who complained that their efforts to bolster the…

  2. Polarization digital holographic microscopy using low-cost liquid crystal polarization rotators

    NASA Astrophysics Data System (ADS)

    Dovhaliuk, Rostyslav Yu

    2018-02-01

    Polarization imaging methods are actively used to study anisotropic objects. A number of methods and systems, such as imaging polarimeters, were proposed to measure the state of polarization of light that passed through the object. Digital holographic and interferometric approaches can be used to quantitatively measure both amplitude and phase of a wavefront. Using polarization modulation optics, the measurement capabilities of such interference-based systems can be extended to measure polarization-dependent parameters, such as phase retardation. Different kinds of polarization rotators can be used to alternate the polarization of a reference beam. Liquid crystals are used in a rapidly increasing number of different optoelectronic devices. Twisted nematic liquid crystals are widely used as amplitude modulators in electronic displays and light valves or shutter glass. Such devices are of particular interest for polarization imaging, as they can be used as polarization rotators, and due to large-scale manufacturing have relatively low cost. A simple Mach-Zehnder polarized holographic setup that uses modified shutter glass as a polarization rotator is demonstrated. The suggested approach is experimentally validated by measuring retardation of quarter-wave film.

  3. A 75-ps Gated CMOS Image Sensor with Low Parasitic Light Sensitivity

    PubMed Central

    Zhang, Fan; Niu, Hanben

    2016-01-01

    In this study, a 40 × 48 pixel global shutter complementary metal-oxide-semiconductor (CMOS) image sensor with an adjustable shutter time as low as 75 ps was implemented using a 0.5-μm mixed-signal CMOS process. The implementation consisted of a continuous contact ring around each p+/n-well photodiode in the pixel array in order to apply sufficient light shielding. The parasitic light sensitivity of the in-pixel storage node was measured to be 1/8.5 × 107 when illuminated by a 405-nm diode laser and 1/1.4 × 104 when illuminated by a 650-nm diode laser. The pixel pitch was 24 μm, the size of the square p+/n-well photodiode in each pixel was 7 μm per side, the measured random readout noise was 217 e− rms, and the measured dynamic range of the pixel of the designed chip was 5500:1. The type of gated CMOS image sensor (CIS) that is proposed here can be used in ultra-fast framing cameras to observe non-repeatable fast-evolving phenomena. PMID:27367699

  4. A 75-ps Gated CMOS Image Sensor with Low Parasitic Light Sensitivity.

    PubMed

    Zhang, Fan; Niu, Hanben

    2016-06-29

    In this study, a 40 × 48 pixel global shutter complementary metal-oxide-semiconductor (CMOS) image sensor with an adjustable shutter time as low as 75 ps was implemented using a 0.5-μm mixed-signal CMOS process. The implementation consisted of a continuous contact ring around each p+/n-well photodiode in the pixel array in order to apply sufficient light shielding. The parasitic light sensitivity of the in-pixel storage node was measured to be 1/8.5 × 10⁷ when illuminated by a 405-nm diode laser and 1/1.4 × 10⁴ when illuminated by a 650-nm diode laser. The pixel pitch was 24 μm, the size of the square p+/n-well photodiode in each pixel was 7 μm per side, the measured random readout noise was 217 e(-) rms, and the measured dynamic range of the pixel of the designed chip was 5500:1. The type of gated CMOS image sensor (CIS) that is proposed here can be used in ultra-fast framing cameras to observe non-repeatable fast-evolving phenomena.

  5. Determination of the solar transmittance for the translucent shutter with PCM in liquid and solid state

    NASA Astrophysics Data System (ADS)

    Komerska, Anna; Ksionek, Dariusz; Rosiński, Marian

    2017-11-01

    This article presents results of the energy performance of an external translucent shading component integrated with a phase change material. A proposed technology is able to accumulate considerable amounts of energy in the latent heat by absorbing solar energy. Due to selective optical properties, much of the visible light is still transmitted through the facade. Experimental measurements were carried out in a laboratory set-up - testing thermal chamber, located in the Faculty of Building Services, Hydro and Environmental Engineering at Warsaw University of Technology. The main result of the experimental study was the evaluation of the average solar transmittance in the whole measured spectrum, as well as in the infrared and visible light. Since the shift in optical properties was observed when the material was undergoing a phase transition, the average spectral transmittances were measured for different states of matter of the PCM material. The tested shutter showed abilities to reduce and modulate daylight and solar heat gains in the indoor environment, which could contribute to considerable energy savings.

  6. Design/Use of the Remotely Operated Bakeout Box Shutter (ROBBS)

    NASA Technical Reports Server (NTRS)

    Ottens, Brian P.

    1999-01-01

    A thermal vacuum box bakeout and certification allows orbital payloads to be cleaned and certified when the background TQCM measurements (a measure of how much molecular contamination is on a payload or chamber) are unacceptable or unmanageable in the standard thermal vacuum chamber. The box bakeout procedure is usually performed in 4 steps: bakeout the box, certify the box, bake out the payload, and finally certify the payload. In the procedure's current setup, the contaminant conduction hole ("lid") is initially open and a vacuum chamber break must occur between the bakeout and certification phases to close the box from the vacuum chamber. This exposure is necessary to allow the outgassed contaminants to escape the box's volume rapidly during bakeout phase, but payload certification isn't usually performed while the lid is still open, because it exposes the payload, TQCM, and box volume to chamber contaminants. The Remotely Operated Bakeout Box Shutter (ROBBS) is a new facility design and will allow the remote closure of the contamination hole while the chamber is still under vacuum, and with little or no time to do so.

  7. Development of X-ray CCD camera based X-ray micro-CT system

    NASA Astrophysics Data System (ADS)

    Sarkar, Partha S.; Ray, N. K.; Pal, Manoj K.; Baribaddala, Ravi; Agrawal, Ashish; Kashyap, Y.; Sinha, A.; Gadkari, S. C.

    2017-02-01

    Availability of microfocus X-ray sources and high resolution X-ray area detectors has made it possible for high resolution microtomography studies to be performed outside the purview of synchrotron. In this paper, we present the work towards the use of an external shutter on a high resolution microtomography system using X-ray CCD camera as a detector. During micro computed tomography experiments, the X-ray source is continuously ON and owing to the readout mechanism of the CCD detector electronics, the detector registers photons reaching it during the read-out period too. This introduces a shadow like pattern in the image known as smear whose direction is defined by the vertical shift register. To resolve this issue, the developed system has been incorporated with a synchronized shutter just in front of the X-ray source. This is positioned in the X-ray beam path during the image readout period and out of the beam path during the image acquisition period. This technique has resulted in improved data quality and hence the same is reflected in the reconstructed images.

  8. Programmable hyperspectral image mapper with on-array processing

    NASA Technical Reports Server (NTRS)

    Cutts, James A. (Inventor)

    1995-01-01

    A hyperspectral imager includes a focal plane having an array of spaced image recording pixels receiving light from a scene moving relative to the focal plane in a longitudinal direction, the recording pixels being transportable at a controllable rate in the focal plane in the longitudinal direction, an electronic shutter for adjusting an exposure time of the focal plane, whereby recording pixels in an active area of the focal plane are removed therefrom and stored upon expiration of the exposure time, an electronic spectral filter for selecting a spectral band of light received by the focal plane from the scene during each exposure time and an electronic controller connected to the focal plane, to the electronic shutter and to the electronic spectral filter for controlling (1) the controllable rate at which the recording is transported in the longitudinal direction, (2) the exposure time, and (3) the spectral band so as to record a selected portion of the scene through M spectral bands with a respective exposure time t(sub q) for each respective spectral band q.

  9. Nonlinear Representation and Pulse Testing of Communication Subsystems.

    DTIC Science & Technology

    1982-05-01

    The Post-Doctoral Program provides an opportunity for faculty at participating universities to spend up to one year full time on explora- tory...development and problem-solving efforts with the post-doctorals splitting their time between the customer location and their educational institutions. The...CHAPTER II z-DOMAIN CHARACTERIZATION OF THE QUJADRATIC VOLTERRA SYSTEM................3 2.1 Continuous- Time Analysis .................. 3 Rational

  10. Experimental and modeling study of the oxidation of acetaldehyde in an atmospheric-pressure pulsed corona discharge

    NASA Astrophysics Data System (ADS)

    Klett, C.; Touchard, S.; Vega-Gonzalez, A.; Redolfi, M.; Bonnin, X.; Hassouni, K.; Duten, X.

    2012-08-01

    This paper reports the results obtained for the degradation of acetaldehyde by an atmospheric plasma corona discharge working in a pulsed regime. It was shown that a few hundred ppm of acetaldehyde diluted in a pure N2 gas flow can be removed up to 80% by a discharge fed with an electric power lower than 1 W. Under the same conditions, adding up to 5% of O2 allowed the removal of up to 95% of the initial acetaldehyde. The main identified end products were CO2, CO and methanol. A quasi-homogeneous zero-dimensional chemical model was developed to investigate the respective efficiency of the discharge and post-discharge periods in the global removal of the pollutant. The identified main pathways of acetaldehyde degradation were quenching of N2 metastable states during plasma pulses and oxidation by O and OH radicals during the post-discharge. This latter contribution increased with input power because of ozone accumulation in the gas mixture acting as an additional oxygen reservoir.

  11. A pilot trial of square biphasic pulse deep brain stimulation for dystonia: The BIP dystonia study.

    PubMed

    Almeida, Leonardo; Martinez-Ramirez, Daniel; Ahmed, Bilal; Deeb, Wissam; Jesus, Sol De; Skinner, Jared; Terza, Matthew J; Akbar, Umer; Raike, Robert S; Hass, Chris J; Okun, Michael S

    2017-04-01

    Dystonia often has inconsistent benefits and requires more energy-demanding DBS settings. Studies suggest that squared biphasic pulses could provide significant clinical benefit; however, dystonia patients have not been explored. To assess safety and tolerability of square biphasic DBS in dystonia patients. This study included primary generalized or cervical dystonia patients with bilateral GPi DBS. Square biphasic pulses were implemented and patients were assessed at baseline, immediately postwashout, post-30-minute washout, 1 hour post- and 2 hours postinitiation of investigational settings. Ten participants completed the study. There were no patient-reported or clinician-observed side effects. There was improvement across time on the Toronto Western Spasmodic Torticollis Rating Scale (χ 2  = 10.7; P = 0.031). Similar improvement was detected in objective gait measurements. Square biphasic stimulation appears safe and feasible in dystonia patients with GPi DBS. Further studies are needed to evaluate possible effectiveness particularly in cervical and gait features. © 2016 International Parkinson and Movement Disorder Society. © 2017 International Parkinson and Movement Disorder Society.

  12. Wood thrush nest success and post-fledging survival across a temporal pulse of small mammal abundance in an oak forest.

    PubMed

    Schmidt, Kenneth A; Rush, Scott A; Ostfeld, Richard S

    2008-07-01

    1. Synchronized mass production of seed crops, such as acorns, produces a resource pulse that may have far-reaching consequences for songbird populations through its effects on avian predators. Seed production in these forests represents only the first of several pulsed events. Secondary pulses emerge as mast-consuming rodents numerically respond to seed production and tertiary pulses emerge as generalist predators, such as raptors, numerically respond to rodents. In turn, these two groups reduce nest productivity and juvenile survivorship 1 and 2 years, respectively, after the initial pulse in seed production. 2. At our study site in south-eastern New York, USA, autumn acorn abundance (primary pulse) largely determines rodent abundance (secondary pulse) the following spring. We tested the hypotheses that the population dynamics of a shrub-nesting passerine (wood thrush Hylocichla mustelina), is influenced by rodents through the: (a) direct effect of predation by rodents; (b) indirect effect of rodents on the abundance of raptors (tertiary pulse); and (c) indirect effect of rodent abundance on raptor diet. The latter specifically hypothesizes that a crash in the rodent population in the wake of region-wide failure of acorn production leads to an extreme diet shift in raptors that increases post-fledging mortality in birds. 3. We conducted a 3-year study to examine variation in wood thrush nest success and fledgling survival, using radio telemetry, across a pulse of rodent abundance (i.e. low, medium and high). We also updated and reanalysed regional wood thrush population growth rates as a function of the annual variation in rodent abundance. 4. Fledgling survivorship, but not nest success, varied in relation to annual rodent abundance. Raptors and eastern chipmunks Tamias striatus were the most commonly identified predators on fledglings. Fledgling survivorship was greatest at intermediate rodent abundance consistent with a shift in raptor diet. Regional rate of wood thrush population growth showed a unimodal relationship with rodent abundance, peaking during years with intermediate rodent abundance. This unimodal pattern was due to wood thrush population growth rates near or below zero during rodent population crashes. 5. The telemetry study, pattern of regional abundance and synchronized population dynamics of coexisting thrushes suggest a common mechanism of behavioural changes in raptors in response to declines in rodent prey, which in turn affects thrush population dynamics.

  13. Phase-selective vanadium dioxide (VO2) nanostructured thin films by pulsed laser deposition

    NASA Astrophysics Data System (ADS)

    Masina, B. N.; Lafane, S.; Wu, L.; Akande, A. A.; Mwakikunga, B.; Abdelli-Messaci, S.; Kerdja, T.; Forbes, A.

    2015-10-01

    Thin films of monoclinic nanostructured vanadium dioxide are notoriously difficult to produce in a selective manner. To date, post-annealing, after pulsed laser deposition (PLD), has been used to revert the crystal phase or to remove impurities, and non-glass substrates have been employed, thus reducing the efficacy of the transparency switching. Here, we overcome these limitations in PLD by optimizing a laser-ablation and deposition process through optical imaging of the laser-induced plasma. We report high quality monoclinic rutile-type vanadium dioxide (VO2) (M1) nanoparticles without post-annealing, and on a glass substrate. Our samples demonstrate a reversible metal-to-insulator transition at ˜43 °C, without any doping, paving the way to switchable transparency in optical materials at room temperature.

  14. Separation of Time Scales in a Quantum Newton’s Cradle

    DOE PAGES

    van den Berg, R.; Wouters, B.; Eliëns, S.; ...

    2016-06-01

    For strongly repulsive bosons in one dimension, we provide detailed modeling of the Bragg pulse used in quantum Newton's cradle-like settings or in Bragg spectroscopy experiments. By employing the Fermi-Bose mapping for a nite harmonically trapped gas and the Quench Action approach for a thermodynamic system on a ring, we reconstruct the exact post-pulse many-body time evolution of Lieb-Liniger gases in the Tonks-Girardeau limit, together with their changing local density pro le and momentum distribution. Our results display a clear separation of timescales between rapid and trap-insensitive relaxation immediately after the pulse, followed by slow in-trap periodic behaviour.

  15. Stroboscopic Vision as a Treatment for Retinal Slip Induced Motion Sickness

    NASA Technical Reports Server (NTRS)

    Reschke, M. F.; Somers, J. T.; Ford, G.; Krnavek, J. M.; Hwang, E. J.; Leigh, R. J.; Estrada, A.

    2007-01-01

    Motion sickness in the general population is a significant problem driven by the increasingly more sophisticated modes of transportation, visual displays, and virtual reality environments. It is important to investigate non-pharmacological alternatives for the prevention of motion sickness for individuals who cannot tolerate the available anti-motion sickness drugs, or who are precluded from medication because of different operational environments. Based on the initial work of Melvill Jones, in which post hoc results indicated that motion sickness symptoms were prevented during visual reversal testing when stroboscopic vision was used to prevent retinal slip, we have evaluated stroboscopic vision as a method of preventing motion sickness in a number of different environments. Specifically, we have undertaken a five part study that was designed to investigate the effect of stroboscopic vision (either with a strobe light or LCD shutter glasses) on motion sickness while: (1) using visual field reversal, (2) reading while riding in a car (with or without external vision present), (3) making large pitch head movements during parabolic flight, (4) during exposure to rough seas in a small boat, and (5) seated and reading in the cabin area of a UH60 Black Hawk Helicopter during 20 min of provocative flight patterns.

  16. Acute Effects of Continuous Positive Air way Pressure on Pulse Pressure in Chronic Heart Failure

    PubMed Central

    Quintão, Mônica; Chermont, Sérgio; Marchese, Luana; Brandão, Lúcia; Bernardez, Sabrina Pereira; Mesquita, Evandro Tinoco; Rocha, Nazareth de Novaes; Nóbrega, Antônio Claudio L.

    2014-01-01

    Background Patients with heart failure (HF) have left ventricular dysfunction and reduced mean arterial pressure (MAP). Increased adrenergic drive causes vasoconstriction and vessel resistance maintaining MAP, while increasing peripheral vascular resistance and conduit vessel stiffness. Increased pulse pressure (PP) reflects a complex interaction of the heart with the arterial and venous systems. Increased PP is an important risk marker in patients with chronic HF (CHF). Non-invasive ventilation (NIV) has been used for acute decompensated HF, to improve congestion and ventilation through both respiratory and hemodynamic effects. However, none of these studies have reported the effect of NIV on PP. Objective The objective of this study was to determine the acute effects of NIV with CPAP on PP in outpatients with CHF. Methods Following a double-blind, randomized, cross-over, and placebo-controlled protocol, twenty three patients with CHF (17 males; 60 ± 11 years; BMI 29 ± 5 kg/cm2, NYHA class II, III) underwent CPAP via nasal mask for 30 min in a recumbent position. Mask pressure was 6 cmH2O, whereas placebo was fixed at 0-1 cmH2O. PP and other non invasive hemodynamics variables were assessed before, during and after placebo and CPAP mode. Results CPAP decreased resting heart rate (Pre: 72 ± 9; vs. Post 5 min: 67 ± 10 bpm; p < 0.01) and MAP (CPAP: 87 ± 11; vs. control 96 ± 11 mmHg; p < 0.05 post 5 min). CPAP decreased PP (CPAP: 47 ± 20 pre to 38 ± 19 mmHg post; vs. control: 42 ± 12 mmHg, pre to 41 ± 18 post p < 0.05 post 5 min). Conclusion NIV with CPAP decreased pulse pressure in patients with stable CHF. Future clinical trials should investigate whether this effect is associated with improved clinical outcome. PMID:24676373

  17. Excitation of H+2 with one-cycle laser pulses: shaped post-laser-field electronic oscillations, generation of higher- and lower-order harmonics

    NASA Astrophysics Data System (ADS)

    Paramonov, Guennaddi K.; Kühn, Oliver; Bandrauk, André D.

    2017-08-01

    Non-Born-Oppenheimer quantum dynamics of H+2 excited by shaped one-cycle laser pulses linearly polarised along the molecular axis have been studied by the numerical solution of the time-dependent Schrödinger equation within a three-dimensional model, including the internuclear separation, R, and the electron coordinates z and ρ. Laser carrier frequencies corresponding to the wavelengths λl = 25 nm through λl = 400 nm were used and the amplitudes of the pulses were chosen such that the energy of H+2 was close to its dissociation threshold at the end of any laser pulse applied. It is shown that there exists a characteristic oscillation frequency ωosc ≃ 0.2265 au (corresponding to the period of τosc ≃ 0.671 fs and the wavelength of λosc ≃ 201 nm) that manifests itself as a 'carrier' frequency of temporally shaped oscillations of the time-dependent expectation values ⟨z ⟩ and ⟨∂V/∂z ⟩ that emerge at the ends of the laser pulses and exist on a timescale of at least 50 fs. Time-dependent expectation values ⟨ρ⟩ and ⟨∂V /∂ρ⟩ of the optically passive degree of freedom, ρ, demonstrate post-laser-field oscillations at two basic frequencies ωρ1 ≈ ωosc and ωρ2 ≈ 2ωosc. Power spectra associated with the electronic motion show higher- and lower-order harmonics with respect to the driving field.

  18. Post-infectious bronchiolitis obliterans in children: CT features that predict responsiveness to pulse methylprednisolone.

    PubMed

    Yoon, H M; Lee, J S; Hwang, J-Y; Cho, Y A; Yoon, H-K; Yu, J; Hong, S-J; Yoon, C H

    2015-05-01

    Intravenous pulse methylprednisolone therapy (IPMT) is an important treatment option for post-infectious obliterative bronchiolitis (OB), although it must be used carefully and only in selected patients because of its drawbacks. This study evaluated whether CT and clinical features of children with post-infectious OB can predict their responsiveness to IPMT. We searched the medical records for patients (less than 18 years of age) who were diagnosed with post-infectious OB between January 2000 and December 2011. 17 children who received IPMT were included in this study. All underwent chest CT before and after IPMT. The radiological features seen on pre-treatment CT were recorded. The air-trapping area percentages on pre- and post-treatment CT images were determined. The nine patients who exhibited decreased air trapping on post-treatment CT scans relative to pre-treatment scans were classed as responders. The patient ages and time from initial pneumonia to IPMT were recorded. All responders and only four non-responders had thickened bronchial walls before treatment (p = 0.029). The two groups did not differ significantly in terms of bronchiolitis, bronchiectasis or the extent of air trapping, although the responders had a significantly shorter median interval between initial pneumonia and IPMT (4 vs 50 months; p = 0.005) and were significantly younger (median, 2.0 vs 7.5 years; p = 0.048). Immediate IPMT may improve the degree of air trapping in children with post-infectious OB if they show a thickened bronchial wall on CT. Children with post-infectious OB may respond favourably to IPMT when pre-treatment CT indicates bronchial-wall thickening.

  19. A detailed view of the gas shell around R Sculptoris with ALMA

    NASA Astrophysics Data System (ADS)

    Maercker, M.; Vlemmings, W. H. T.; Brunner, M.; De Beck, E.; Humphreys, E. M.; Kerschbaum, F.; Lindqvist, M.; Olofsson, H.; Ramstedt, S.

    2016-02-01

    Context. During the asymptotic giant branch (AGB) phase, stars undergo thermal pulses - short-lived phases of explosive helium burning in a shell around the stellar core. Thermal pulses lead to the formation and mixing-up of new elements to the stellar surface. They are hence fundamental to the chemical evolution of the star and its circumstellar envelope. A further consequence of thermal pulses is the formation of detached shells of gas and dust around the star, several of which have been observed around carbon-rich AGB stars. Aims: We aim to determine the physical properties of the detached gas shell around R Sculptoris, in particular the shell mass and temperature, and to constrain the evolution of the mass-loss rate during and after a thermal pulse. Methods: We analyse 12CO(1-0), 12CO(2-1), and 12CO(3-2) emission, observed with the Atacama Large Millimeter/submillimeter Array (ALMA) during Cycle 0 and complemented by single-dish observations. The spatial resolution of the ALMA data allows us to separate the detached shell emission from the extended emission inside the shell. We perform radiative transfer modelling of both components to determine the shell properties and the post-pulse mass-loss properties. Results: The ALMA data show a gas shell with a radius of 19.̋5 expanding at 14.3 km s-1. The different scales probed by the ALMA Cycle 0 array show that the shell must be entirely filled with gas, contrary to the idea of a detached shell. The comparison to single-dish spectra and radiative transfer modelling confirms this. We derive a shell mass of 4.5 × 10-3 M⊙ with a temperature of 50 K. Typical timescales for thermal pulses imply a pulse mass-loss rate of 2.3 × 10-5 M⊙ yr-1. For the post-pulse mass-loss rate, we find evidence for a gradual decline of the mass-loss rate, with an average value of 1.6 × 10-5 M⊙ yr-1. The total amount of mass lost since the last thermal pulse is 0.03 M⊙, a factor four higher compared to classical models, with a sharp decline in mass-loss rate immediately after the pulse. Conclusions: We find that the mass-loss rate after a thermal pulse has to decline more slowly than generally expected from models of thermal pulses. This may cause the star to lose significantly more mass during a thermal pulse cycle, which affects the lifetime on the AGB and the chemical evolution of the star, its circumstellar envelope, and the interstellar medium.

  20. Post-fire logging reduces surface woody fuels up to four decades following wildfire

    Treesearch

    David W. Peterson; Erich Kyle Dodson; Richy J. Harrod

    2015-01-01

    Severe wildfires create pulses of dead trees that influence future fuel loads, fire behavior, and fire effects as they decay and deposit surface woody fuels. Harvesting fire-killed trees may reduce future surface woody fuels and related fire hazards, but the magnitude and timing of post-fire logging effects on woody fuels have not been fully assessed. To address this...

  1. Apollo 8 Mission image,Farside of Moon

    NASA Image and Video Library

    1968-12-21

    Apollo 8,Farside of Moon. Image taken on Revolution 4. Camera Tilt Mode: Vertical Stereo. Sun Angle: 13. Original Film Magazine was labeled D. Camera Data: 70mm Hasselblad. Lens: 80mm; F-Stop: F/2.8; Shutter Speed: 1/250 second. Film Type: Kodak SO-3400 Black and White,ASA 40. Flight Date: December 21-27,1968.

  2. Why Do Photo Finish Images Look Weird?

    ERIC Educational Resources Information Center

    Gregorcic, Bor; Planinsic, Gorazd

    2012-01-01

    This paper deals with effects that appear on photographs of rotating objects when taken by a photo finish camera, a rolling shutter camera or a computer scanner. These effects are very similar to Roget's palisade illusion. A simple quantitative analysis of the images is also provided. The effects are explored using a computer scanner in a way that…

  3. Portrait of the Rural Community College. New Directions for Community Colleges, Number 90.

    ERIC Educational Resources Information Center

    Killacky, Jim, Ed.; Valadez, James R., Ed.

    1995-01-01

    This collection of essays attempts to describe the status and role of the rural community college in higher education, highlighting the special challenges faced by these institutions. The following articles are included: (1) "Opening the Shutter," by James R. Valadez and Jim Killacky; (2) "The Comprehensive Mission of the Rural Community College,"…

  4. School Closings No Fiscal Savior, Study Cautions

    ERIC Educational Resources Information Center

    Samuels, Christina A.

    2011-01-01

    If big-city districts are looking to close budget gaps, shuttering schools may not be the best strategy. Closing schools does not save very much money in the context of an urban district's budget, and selling or leasing surplus school buildings tends to be difficult because they're often old and in struggling neighborhoods, a recent report from a…

  5. Post-seismic and interseismic fault creep I: model description

    NASA Astrophysics Data System (ADS)

    Hetland, E. A.; Simons, M.; Dunham, E. M.

    2010-04-01

    We present a model of localized, aseismic fault creep during the full interseismic period, including both transient and steady fault creep, in response to a sequence of imposed coseismic slip events and tectonic loading. We consider the behaviour of models with linear viscous, non-linear viscous, rate-dependent friction, and rate- and state-dependent friction fault rheologies. Both the transient post-seismic creep and the pattern of steady interseismic creep rates surrounding asperities depend on recent coseismic slip and fault rheologies. In these models, post-seismic fault creep is manifest as pulses of elevated creep rates that propagate from the coseismic slip, these pulses feature sharper fronts and are longer lived in models with rate-state friction compared to other models. With small characteristic slip distances in rate-state friction models, interseismic creep is similar to that in models with rate-dependent friction faults, except for the earliest periods of post-seismic creep. Our model can be used to constrain fault rheologies from geodetic observations in cases where the coseismic slip history is relatively well known. When only considering surface deformation over a short period of time, there are strong trade-offs between fault rheology and the details of the imposed coseismic slip. Geodetic observations over longer times following an earthquake will reduce these trade-offs, while simultaneous modelling of interseismic and post-seismic observations provide the strongest constraints on fault rheologies.

  6. Pulsed optical fibre lasers: Self-pulsation, Q-switching and tissue interactions

    NASA Astrophysics Data System (ADS)

    El-Sherif, Ashraf Fathy

    The experimental and theoretical aspects of self-pulsing and dynamics effects of a CW Tm3+-doped silica fibre laser operating near 2 mum are investigated and examined for the first time. Various self-pulsing regimes are observed for a range of pumping rates when the fibre is end-pumped with a high power Nd:YAG laser operating at 1.319 mum in a linear bidirectional cavity. A theoretical model based on pair induced quenching (PIQ) is considered. The quenching effect acts as a saturable absorber or an additional dynamical loss mechanism, this additional absorber then may make the laser system unstable depending on whether the obtained steady-state solution is stable or not. A comparison between measured self-pulsation frequency and calculated relaxation oscillation frequency as a function of pumping rate is presented and discussed. High performance operation of a mechanical shutter Q-switched Tm3+-doped silica fibre laser operating near 2 mum is observed and presented. A single Q-switched pulse with peak power of 18.5 W and pulse duration at full width half maximum (FWHM) of 300 ns at higher mechanical chopper frequencies of nearly 20 kHz is achieved. The pulse-to-pulse stability was measured and improved to be more less than 5 %. The development, optimisation of the performance and analysis of an acousto-optic modulator (AOM) Q-switched Tm3+-doped silica fibre laser operating near 2 mum are presented. The shortest pulse duration obtained was 150 ns, giving a highest peak power of 4.1 kW, and is the highest yet reported from any type of active Q-switched fibre laser operating in low order mode. The maximum peak power was obtained for an optimum cavity length of 1.15 meters made up of fibre length, Q-switch crystal and passive space. The pulse train with high pulse-to-pulse stability of 1 % occurred at a range of high repetition rates from 10 to 30 kHz. High energy, high brightness of an electro-optic modulator (EOM) Q-switched Tm3+-doped silica fibre laser operating near 2 mum is presented. Appropriate design precautions have been undertaken to ensure that prelasing does not occur. In this system, the main Q-switched pulse may be followed by one pulse of lower amplitude "postlasing" when an optimised quarter wave voltage of 750 V is applied. It was found that the laser produced 320 ns pulses with 2.5 mJ pulse energy and 3.3 kW peak power at low repetition rates of 50-70 Hz. This is the first time that such studies of electro-optic modulator (EOM) Q-switched Tm3+ fibre lasers have been reported. The maximum peak power was obtained for an optimum cavity length of 2.15 meters, made up of fibre length, broadband beamsplitter polarizer, Q-switch crystal and passive space. Computer simulation of Tm3+doped silica and Er2-doped fluorozirconate fibre lasers using general laser analysis and design (GLAD) software has been successfully investigated for the first time. Input files, which are very similar to language are created to model three designs of fibre lasers, two for Tm3+-doped silica fibre lasers, core pumped at 1.57 mum and cladding pumped at 790 nm, and one for a 2.7 mum Er3+-doped fluorozirconate fibre laser cladding pumped at 975 nm. Results are presented from a relatively comprehensive computer model, which simulates CW operation of the fibre lasers. The simulation suggests that to enhance the conversion energy we have to optimise between the absorption coefficient of the fibre and the diffraction algorithms. Comparison of soft and hard tissue ablation with high peak power Q-switched and CW Tm3+-silica fibre lasers are presented. The ablation of chicken breast and lamb liver tissues as a soft tissue and cartilage as a hard tissue have been investigated using a free running CW-Tm3+-doped fibre laser (wavelength 1.99 mum, with self-pulsation duration ranging over 1 to few tens of microseconds) and for Q-switched operation of the same laser (pulse duration ranging from 150 ns to 900 ns and pulse repetition rates from 100 Hz to 17 kHz). Residual damage and affected zones using the CW laser were nearly 6 times greater than using the Q-switched fibre laser for about 50 s of exposure time, and increased with pulse repetition rate. The energy required to ablate tissues with the CW-fibre laser ranged from 153 to 334 kJ/cm3 and was significantly smaller from 0.2 to 0.6 kJ/cm3 for the Q-switched fibre laser. This study is the first direct comparison of tissue interaction of CW and Q- switched Tm3+-doped silica fibre lasers on crater depth, heat of ablation and collateral damage. The Q-switched Tm3+-doped silica fibre laser effectively ablates tissue with little secondary damage.

  7. Validating hydrodynamic growth in National Ignition Facility implosions

    DOE PAGES

    Peterson, J. L.; Casey, D. T.; Hurricane, O. A.; ...

    2015-05-12

    We present new hydrodynamic growth experiments at the National Ignition Facility, which extend previous measurements up to Legendre mode 160 and convergence ratio 4, continuing the growth factor dispersion curve comparison of the low foot and high foot pulses reported by Casey et al. [Phys. Rev. E 90, 011102(R) (2014)]. We show that the high foot pulse has lower growth factor and lower growth rate than the low foot pulse. Using novel on-capsule fiducial markers, we observe that mode 160 inverts sign (changes phase) for the high foot pulse, evidence of amplitude oscillations during the Richtmyer-Meshkov phase of a sphericallymore » convergent system. Post-shot simulations are consistent with the experimental measurements for all but the shortest wavelength perturbations, reinforcing the validity of radiation hydrodynamic simulations of ablation front growth in inertial confinement fusion capsules.« less

  8. Dynamic control of laser driven proton beams by exploiting self-generated, ultrashort electromagnetic pulses

    NASA Astrophysics Data System (ADS)

    Kar, S.; Ahmed, H.; Nersisyan, G.; Brauckmann, S.; Hanton, F.; Giesecke, A. L.; Naughton, K.; Willi, O.; Lewis, C. L. S.; Borghesi, M.

    2016-05-01

    As part of the ultrafast charge dynamics initiated by high intensity laser irradiations of solid targets, high amplitude EM pulses propagate away from the interaction point and are transported along any stalks and wires attached to the target. The propagation of these high amplitude pulses along a thin wire connected to a laser irradiated target was diagnosed via the proton radiography technique, measuring a pulse duration of ˜20 ps and a pulse velocity close to the speed of light. The strong electric field associated with the EM pulse can be exploited for controlling dynamically the proton beams produced from a laser-driven source. Chromatic divergence control of broadband laser driven protons (upto 75% reduction in divergence of >5 MeV protons) was obtained by winding the supporting wire around the proton beam axis to create a helical coil structure. In addition to providing focussing and energy selection, the technique has the potential to post-accelerate the transiting protons by the longitudinal component of the curved electric field lines produced by the helical coil lens.

  9. Development of Bipolar Pulse Accelerator for Pulsed Ion Beam Implantation to Semiconductor

    NASA Astrophysics Data System (ADS)

    Masugata, Katsumi; Kawahara, Yoshihiro; Mitsui, Chihiro; Kitamura, Iwao; Takahashi, Takakazu; Tanaka, Yasunori; Tanoue, Hisao; Arai, Kazuo

    2002-12-01

    To improve the purity of the ion beams new type of pulsed power ion accelerator named "bipolar pulse accelerator" was proposed. The accelerator consists of two acceleration gaps (an ion source gap and a post acceleration gap) and a drift tube, and a bipolar pulse is applied to the drift tube to accelerate the beam. In the accelerator intended ions are selectively accelerated and the purity of the ion beam is enhanced. As the first step of the development of the accelerator, a Br-type magnetically insulated acceleration gap is developed. The gap has an ion source of coaxial gas puff plasma gun on the grounded anode and a negative pulse is applied to the cathode to accelerate the ion beam. By using the plasma gun, ion source plasma (nitrogen) of current density around 100 A/cm2 is obtained. In the paper, the experimental results of the evaluation of the ion beam and the characteristics of the gap are shown with the principle and the design concept of the proposed accelerator.

  10. Dynamic control of laser driven proton beams by exploiting self-generated, ultrashort electromagnetic pulses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kar, S., E-mail: s.kar@qub.ac.uk; Ahmed, H.; Nersisyan, G.

    As part of the ultrafast charge dynamics initiated by high intensity laser irradiations of solid targets, high amplitude EM pulses propagate away from the interaction point and are transported along any stalks and wires attached to the target. The propagation of these high amplitude pulses along a thin wire connected to a laser irradiated target was diagnosed via the proton radiography technique, measuring a pulse duration of ∼20 ps and a pulse velocity close to the speed of light. The strong electric field associated with the EM pulse can be exploited for controlling dynamically the proton beams produced from amore » laser-driven source. Chromatic divergence control of broadband laser driven protons (upto 75% reduction in divergence of >5 MeV protons) was obtained by winding the supporting wire around the proton beam axis to create a helical coil structure. In addition to providing focussing and energy selection, the technique has the potential to post-accelerate the transiting protons by the longitudinal component of the curved electric field lines produced by the helical coil lens.« less

  11. Potentiostatic pulse-deposition of calcium phosphate on magnesium alloy for temporary implant applications--an in vitro corrosion study.

    PubMed

    Kannan, M Bobby; Wallipa, O

    2013-03-01

    In this study, a magnesium alloy (AZ91) was coated with calcium phosphate using potentiostatic pulse-potential and constant-potential methods and the in vitro corrosion behaviour of the coated samples was compared with the bare metal. In vitro corrosion studies were carried out using electrochemical impedance spectroscopy and potentiodynamic polarization in simulated body fluid (SBF) at 37 °C. Calcium phosphate coatings enhanced the corrosion resistance of the alloy, however, the pulse-potential coating performed better than the constant-potential coating. The pulse-potential coating exhibited ~3 times higher polarization resistance than that of the constant-potential coating. The corrosion current density obtained from the potentiodynamic polarization curves was significantly less (~60%) for the pulse-deposition coating as compared to the constant-potential coating. Post-corrosion analysis revealed only slight corrosion on the pulse-potential coating, whereas the constant-potential coating exhibited a large number of corrosion particles attached to the coating. The better in vitro corrosion performance of the pulse-potential coating can be attributed to the closely packed calcium phosphate particles. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Implementation of continuous-variable quantum key distribution with discrete modulation

    NASA Astrophysics Data System (ADS)

    Hirano, Takuya; Ichikawa, Tsubasa; Matsubara, Takuto; Ono, Motoharu; Oguri, Yusuke; Namiki, Ryo; Kasai, Kenta; Matsumoto, Ryutaroh; Tsurumaru, Toyohiro

    2017-06-01

    We have developed a continuous-variable quantum key distribution (CV-QKD) system that employs discrete quadrature-amplitude modulation and homodyne detection of coherent states of light. We experimentally demonstrated automated secure key generation with a rate of 50 kbps when a quantum channel is a 10 km optical fibre. The CV-QKD system utilises a four-state and post-selection protocol and generates a secure key against the entangling cloner attack. We used a pulsed light source of 1550 nm wavelength with a repetition rate of 10 MHz. A commercially available balanced receiver is used to realise shot-noise-limited pulsed homodyne detection. We used a non-binary LDPC code for error correction (reverse reconciliation) and the Toeplitz matrix multiplication for privacy amplification. A graphical processing unit card is used to accelerate the software-based post-processing.

  13. Phase-selective vanadium dioxide (VO{sub 2}) nanostructured thin films by pulsed laser deposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Masina, B. N., E-mail: BMasina@csir.co.za, E-mail: slafane@cdta.dz; School of Physics, University of KwaZulu-Natal, Private Bag X54001, Durban 4000; Lafane, S., E-mail: BMasina@csir.co.za, E-mail: slafane@cdta.dz

    2015-10-28

    Thin films of monoclinic nanostructured vanadium dioxide are notoriously difficult to produce in a selective manner. To date, post-annealing, after pulsed laser deposition (PLD), has been used to revert the crystal phase or to remove impurities, and non-glass substrates have been employed, thus reducing the efficacy of the transparency switching. Here, we overcome these limitations in PLD by optimizing a laser-ablation and deposition process through optical imaging of the laser-induced plasma. We report high quality monoclinic rutile-type vanadium dioxide (VO{sub 2}) (M1) nanoparticles without post-annealing, and on a glass substrate. Our samples demonstrate a reversible metal-to-insulator transition at ∼43 °C, withoutmore » any doping, paving the way to switchable transparency in optical materials at room temperature.« less

  14. Mass-dependent channel electron multiplier operation. [for ion detection

    NASA Technical Reports Server (NTRS)

    Fields, S. A.; Burch, J. L.; Oran, W. A.

    1977-01-01

    The absolute counting efficiency and pulse height distributions of a continuous-channel electron multiplier used in the detection of hydrogen, argon and xenon ions are assessed. The assessment technique, which involves the post-acceleration of 8-eV ion beams to energies from 100 to 4000 eV, provides information on counting efficiency versus post-acceleration voltage characteristics over a wide range of ion mass. The charge pulse height distributions for H2 (+), A (+) and Xe (+) were measured by operating the experimental apparatus in a marginally gain-saturated mode. It was found that gain saturation occurs at lower channel multiplier operating voltages for light ions such as H2 (+) than for the heavier ions A (+) and Xe (+), suggesting that the technique may be used to discriminate between these two classes of ions in electrostatic analyzers.

  15. Therapeutic Pulsed Ultrasound Promotes Revascularization and Functional Recovery of Rat Skeletal Muscle after Contusion Injury.

    PubMed

    Chongsatientam, Areeya; Yimlamai, Tossaporn

    2016-12-01

    The mechanism by which therapeutic pulsed ultrasound (TPU) promotes the repair of damaged gastrocnemius muscle was investigated. Male Wistar rats were divided into uninjured, sham-treated injured and TPU-treated injured (TPU) groups. Injury was induced by mass-drop technique. TPU was applied to the injured muscle for 5 min, daily, started at day 1 post-injury and continuing for 3, 7 and 14 d. For 3 d post-injury, a significant reduction in muscle force was observed in both the sham-treated injured and TPU groups. TPU treatment significantly increased recovery force of the injured muscle after day 7 post-injury. This effect of TPU is associated with increased centronucleated fibers and cross-sectional area, mRNA expression of the vascular endothelial growth factor and capillary density of the regenerated fibers, but not with mRNA expression of nitric oxide synthase. We conclude that TPU hastens muscle recovery, at least in part, by upregulating angiogenesis. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  16. Control of laser-ablated aluminum surface wettability to superhydrophobic or superhydrophilic through simple heat treatment or water boiling post-processing

    NASA Astrophysics Data System (ADS)

    Ngo, Chi-Vinh; Chun, Doo-Man

    2018-03-01

    Recently, controlling the wettability of a metallic surface so that it is either superhydrophobic or superhydrophilic has become important for many applications. However, conventional techniques require long fabrication times or involve toxic chemicals. Herein, through a combination of pulse laser ablation and simple post-processing, the surface of aluminum was controlled to either superhydrophobic or superhydrophilic in a short time of only a few hours. In this study, grid patterns were first fabricated on aluminum using a nanosecond pulsed laser, and then additional post-processing without any chemicals was used. Under heat treatment, the surface became superhydrophobic with a contact angle (CA) greater than 150° and a sliding angle (SA) lower than 10°. Conversely, when immersed in boiling water, the surface became superhydrophilic with a low contact angle. The mechanism for wettability change was also explained. The surfaces, obtained in a short time with environmentally friendly fabrication and without the use of toxic chemicals, could potentially be applied in various industry and manufacturing applications such as self-cleaning, anti-icing, and biomedical devices.

  17. Fast wettability transition from hydrophilic to superhydrophobic laser-textured stainless steel surfaces under low-temperature annealing

    NASA Astrophysics Data System (ADS)

    Ngo, Chi-Vinh; Chun, Doo-Man

    2017-07-01

    Recently, the fabrication of superhydrophobic metallic surfaces by means of pulsed laser texturing has been developed. After laser texturing, samples are typically chemically coated or aged in ambient air for a relatively long time of several weeks to achieve superhydrophobicity. To accelerate the wettability transition from hydrophilicity to superhydrophobicity without the use of additional chemical treatment, a simple annealing post process has been developed. In the present work, grid patterns were first fabricated on stainless steel by a nanosecond pulsed laser, then an additional low-temperature annealing post process at 100 °C was applied. The effect of 100-500 μm step size of the textured grid upon the wettability transition time was also investigated. The proposed post process reduced the transition time from a couple of months to within several hours. All samples showed superhydrophobicity with contact angles greater than 160° and sliding angles smaller than 10° except samples with 500 μm step size, and could be applied in several potential applications such as self-cleaning and control of water adhesion.

  18. Neutron/ γ-ray digital pulse shape discrimination with organic scintillators

    NASA Astrophysics Data System (ADS)

    Kaschuck, Y.; Esposito, B.

    2005-10-01

    Neutrons and γ-rays produce light pulses with different shapes when interacting with organic scintillators. This property is commonly used to distinguish between neutrons (n) and γ-rays ( γ) in mixed n/ γ fields as those encountered in radiation physics experiments. Although analog electronic pulse shape discrimination (PSD) modules have been successfully used for many years, they do not allow data reprocessing and are limited in count rate capability (typically up to 200 kHz). The performance of a n/ γ digital pulse shape discrimination (DPSD) system by means of a commercial 12-bit 200 MSamples/s transient recorder card is investigated here. Three organic scintillators have been studied: stilbene, NE213 and anthracene. The charge comparison method has been used to obtain simultaneous n/ γ discrimination and pulse height analysis. The importance of DPSD for high-intensity radiation field measurements and its advantages with respect to analog PSD are discussed. Based on post-experiment simulations with acquired data, the requirements for fast digitizers to provide DPSD with organic scintillators are also analyzed.

  19. Pulsed laser manipulation of an optically trapped bead: averaging thermal noise and measuring the pulsed force amplitude.

    PubMed

    Lindballe, Thue B; Kristensen, Martin V G; Berg-Sørensen, Kirstine; Keiding, Søren R; Stapelfeldt, Henrik

    2013-01-28

    An experimental strategy for post-eliminating thermal noise on position measurements of optically trapped particles is presented. Using a nanosecond pulsed laser, synchronized to the detection system, to exert a periodic driving force on an optically trapped 10 μm polystyrene bead, the laser pulse-bead interaction is repeated hundreds of times. Traces with the bead position following the prompt displacement from equilibrium, induced by each laser pulse, are averaged and reveal the underlying deterministic motion of the bead, which is not visible in a single trace due to thermal noise. The motion of the bead is analyzed from the direct time-dependent position measurements and from the power spectrum. The results show that the bead is on average displaced 208 nm from the trap center and exposed to a force amplitude of 71 nanoNewton, more than five orders of magnitude larger than the trapping forces. Our experimental method may have implications for microrheology.

  20. Pulsed laser deposition of piezoelectric lead zirconate titanate thin films maintaining a post-CMOS compatible thermal budget

    NASA Astrophysics Data System (ADS)

    Schatz, A.; Pantel, D.; Hanemann, T.

    2017-09-01

    Integration of lead zirconate titanate (Pb[Zrx,Ti1-x]O3 - PZT) thin films on complementary metal-oxide semiconductor substrates (CMOS) is difficult due to the usually high crystallization temperature of the piezoelectric perovskite PZT phase, which harms the CMOS circuits. In this work, a wafer-scale pulsed laser deposition tool was used to grow 1 μm thick PZT thin films on 150 mm diameter silicon wafers. Three different routes towards a post-CMOS compatible deposition process were investigated, maintaining a post-CMOS compatible thermal budget limit of 445 °C for 1 h (or 420 °C for 6 h). By crystallizing the perovskite LaNiO3 seed layer at 445 °C, the PZT deposition temperature can be lowered to below 400 °C, yielding a transverse piezoelectric coefficient e31,f of -9.3 C/m2. With the same procedure, applying a slightly higher PZT deposition temperature of 420 °C, an e31,f of -10.3 C/m2 can be reached. The low leakage current density of below 3 × 10-6 A/cm2 at 200 kV/cm allows for application of the post-CMOS compatible PZT thin films in low power micro-electro-mechanical-systems actuators.

  1. Effect of different musical tempo on post-exercise recovery in young adults.

    PubMed

    Savitha, D; Mallikarjuna, Reddy N; Rao, Chythra

    2010-01-01

    The role of music in increasing the exercise performance is well recognised. There is very little information about effect of music on time taken for post exercise recovery. We examined the effect of music and different musical tempo on post exercise recovery time, following treadmill work. 30 volunteers (15 male, 15 female) subjected to isotonic exercise (submaximal treadmill work) on three consecutive days. They were allowed to rest in silence on the first day, rest by hearing slow music on second day and rest with fast music on third day. Parameters such as Pulse rate, blood pressure, rating of perceived exertion (RPE) were measured at predetermined intervals. Repeated measures ANOVA test showed that with slow music, recovery time of systolic blood pressure (SBP) (7.9 +/- 2.5), diastolic blood pressure (DBP) (5.5 +/- 3.4) pulse rate recovery (PR) (8.0 +/- 2.3) and recovery from exertion (RPE) (7.7 +/- 2.5) were significantly faster when compared to both no music and fast music. The individual music preference made no significant difference in the relaxation time. The study concluded that music hastens post exercise recovery and slow music has greater relaxation effect than fast or no music, recovery time being independent of the gender and individual music preference.

  2. Quantifying activation of perfluorocarbon-based phase-change contrast agents using simultaneous acoustic and optical observation.

    PubMed

    Li, Sinan; Lin, Shengtao; Cheng, Yi; Matsunaga, Terry O; Eckersley, Robert J; Tang, Meng-Xing

    2015-05-01

    Phase-change contrast agents in the form of nanoscale droplets can be activated into microbubbles by ultrasound, extending the contrast beyond the vasculature. This article describes simultaneous optical and acoustical measurements for quantifying the ultrasound activation of phase-change contrast agents over a range of concentrations. In experiments, decafluorobutane-based nanodroplets of different dilutions were sonicated with a high-pressure activation pulse and two low-pressure interrogation pulses immediately before and after the activation pulse. The differences between the pre- and post-interrogation signals were calculated to quantify the acoustic power scattered by the microbubbles activated over a range of droplet concentrations. Optical observation occurred simultaneously with the acoustic measurement, and the pre- and post-microscopy images were processed to generate an independent quantitative indicator of the activated microbubble concentration. Both optical and acoustic measurements revealed linear relationships to the droplet concentration at a low concentration range <10(8)/mL when measured at body temperature. Further increases in droplet concentration resulted in saturation of the acoustic interrogation signal. Compared with body temperature, room temperature was found to produce much fewer and larger bubbles after ultrasound droplet activation. Copyright © 2015. Published by Elsevier Inc.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joyce, M. J.; Aspinall, M. D.; Cave, F. D.

    Pulse-shape discrimination (PSD) in fast, organic scintillation detectors is a long-established technique used to separate neutrons and {gamma} rays in mixed radiation fields. In the analogue domain the method can achieve separation in real time, but all knowledge of the pulses themselves is lost thereby preventing the possibility of any post- or repeated analysis. Also, it is typically reliant on electronic systems that are largely obsolete and which require significant experience to set up. In the digital domain, PSD is often more flexible but significant post-processing has usually been necessary to obtain neutron/{gamma}-ray separation. Moreover, the scintillation media on whichmore » the technique relies usually have a low flash point and are thus deemed hazardous. This complicates the ease with which they are used in industrial applications. In this paper, results obtained with a new portable digital pulse-shape discrimination instrument are described. This instrument provides real-time, digital neutron/{gamma} separation whilst preserving the synchronization with the time-of-arrival for each event, and realizing throughputs of 3 x 10{sup 6} events per second. Furthermore, this system has been tested with a scintillation medium that is non-flammable and not hazardous. (authors)« less

  4. A Novel Pulse-Chase Paradigm to Visualize the Trafficking of Transport Vesicles in Neurons

    NASA Astrophysics Data System (ADS)

    Al-Bassam, Sarmad

    In neurons transmembrane proteins are targeted to dendrites in vesicles that traffic solely within the somatodendritic compartment. How these vesicles are retained within the somatodendritic domain is unknown. Here we adapt a novel pulse chase system that allows synchronous release of exogenous transmembrane proteins from the endoplasmic reticulum using FKBP12 and Rapamycin. We demonstrate proof-of-concept and establish protein trafficking controls in incremental steps. We demonstrate the utility of this approach in studying protein trafficking and establish parameters for analysis of time-lapse images. We implement this novel pulse-chase strategy to track the movements of post-Golgi transport vesicles. Surprisingly, we found that post-Golgi vesicles carrying dendritic proteins were equally likely to enter axons and dendrites. However, once such vesicles entered the axon they very rarely moved beyond the axon initial segment, but instead either halted or reversed direction in an actin and Myosin Va-dependent manner. In contrast, vesicles carrying either an axonal or a nonspecifically localized protein only rarely halted or reversed and instead generally proceeded to the distal axon. Thus, our results are consistent with the axon initial segment behaving as a vesicle filter that mediates the differential trafficking of transport vesicles.

  5. The Shuttering of Educational Studies: Neoliberalism, the Political Spectacle, and Social Injustice at a "World Class" University

    ERIC Educational Resources Information Center

    Dunn, Alyssa Hadley; Faison, Morgan Zacheya-Jewel

    2015-01-01

    This article examines the September 2012 closure of the Division of Educational Studies (DES) at Emory University. The authors present this discussion as an example of the ways that the neoliberalization of higher education contributes to the extinction of educational foundations programs. What happened at Emory is symptomatic of the impact that…

  6. Collateral Damage

    DTIC Science & Technology

    1978-10-01

    stated, they are, in reality , indexed to a single aspect of the weapon phenomena, e.g., damage levels for airblast-sensitive objects are indexed to...of Burst Propagation Related Airblast Representation Target Altitude Wheather (snow/rain) Terrain Temperature Air Pressure Around Structures 1. d) 3-38...with opaque material. Simply closing a shutter can be quite effective in virtually eliminating all possibility of interior fire starts from a single

  7. Phonation Threshold Pressure Measurement with a Semi-Occluded Vocal Tract

    ERIC Educational Resources Information Center

    Titze, Ingo R.

    2009-01-01

    Purpose: The purpose of this article was to determine if a semi-occluded vocal tract could be used to measure phonation threshold pressure. This is in contrast to the shutter technique, where an alternation between a fully occluded tract and an unoccluded tract is used. Method: Five male and 5 female volunteers phonated through a thin straw held…

  8. A Simple Model of the Accommodating Lens of the Human Eye

    ERIC Educational Resources Information Center

    Oommen, Vinay; Kanthakumar, Praghalathan

    2014-01-01

    The human eye is often discussed as optically equivalent to a photographic camera. The iris is compared with the shutter, the pupil to the aperture, and the retina to the film, and both have lens systems to focus rays of light. Although many similarities exist, a major difference between the two systems is the mechanism involved in focusing an…

  9. Dips in Enrollment Posing Challenges for Urban Districts

    ERIC Educational Resources Information Center

    Gehring, John

    2005-01-01

    Across the U.S., urban school districts are losing students and shuttering schools. In Detroit, some 35,000 students have left the city schools in less than a decade, and the city will close 34 schools and reassign more than 10,000 students in 2006. However, the trend is not limited to Rust Belt cities like Detroit, although their problems tend to…

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, A. A.; Hesjedal, T.; Diamond Light Source, Didcot OX11 0DE

    We present a miniaturized molecular beam epitaxy (miniMBE) system with an outer diameter of 206 mm, optimized for flexible and high-throughput operation. The three-chamber system, used here for oxide growth, consists of a sample loading chamber, a storage chamber, and a growth chamber. The growth chamber is equipped with eight identical effusion cell ports with linear shutters, one larger port for either a multi-pocket electron beam evaporator or an oxygen plasma source, an integrated cryoshroud, retractable beam-flux monitor or quartz-crystal microbalance, reflection high energy electron diffraction, substrate manipulator, main shutter, and quadrupole mass spectrometer. The system can be combined withmore » ultrahigh vacuum (UHV) end stations on synchrotron and neutron beamlines, or equivalently with other complex surface analysis systems, including low-temperature scanning probe microscopy systems. Substrate handling is compatible with most UHV surface characterization systems, as the miniMBE can accommodate standard surface science sample holders. We introduce the design of the system, and its specific capabilities and operational parameters, and we demonstrate the epitaxial thin film growth of magnetoelectric Cr{sub 2}O{sub 3} on c-plane sapphire and ferrimagnetic Fe{sub 3}O{sub 4} on MgO (001)« less

  11. Stroboscopic Vision as a Treatment Motion Sickness

    NASA Technical Reports Server (NTRS)

    Reschke, Millard F.; Somers, J. T.; Ford, G.; Krnavek, J. M.; Hwang, E. y.; Kornilova, L. N.; Leigh, R. J.

    2006-01-01

    Results obtained from space flight indicate that most space crews will experience some symptoms of motion sickness causing significant impact on the operational objectives that must be accomplished to assure mission success. Based on the initial work of Melvill-Jones, we have evaluated stroboscopic vision as a method of preventing motion sickness. Methods: Nineteen subjects read text while making +/-20deg head movements in the horizontal plane at 0.2 Hz while wearing left-right reversing prisms during exposure to 4 Hz stroboscopic or normal room illumination. Testing was repeated using LCD shutter glasses as the stroboscopic source with an additional 19 subjects. Results: With Strobe, motion sickness was significantly lower than with normal room illumination. Results with the LCD shutter glasses were analogous to those observed with environmental strobe. Conclusions: Stroboscopic illumination appears to be effective where retinal slip is a factor in eliciting motion sickness. Additional research is evaluating the glasses efficacy for, carsickness, sickness in parabolic flight and seasickness. There is evidence from pilot studies showing that the glasses reduce saccade velocity to visually presented targets by approximately half of the normal values. It is interesting to note that adaptation to space flight may also slow saccade velocity.

  12. Performance analysis and enhancement for visible light communication using CMOS sensors

    NASA Astrophysics Data System (ADS)

    Guan, Weipeng; Wu, Yuxiang; Xie, Canyu; Fang, Liangtao; Liu, Xiaowei; Chen, Yingcong

    2018-03-01

    Complementary Metal-Oxide-Semiconductor (CMOS) sensors are widely used in mobile-phone and cameras. Hence, it is attractive if these camera can be used as the receivers of visible light communication (VLC). Using the rolling shutter mechanism can increase the data rate of VLC based on CMOS camera, and different techniques have been proposed to improve the demodulation of the rolling shutter mechanism. However, these techniques are too complexity. In this work, we demonstrate and analyze the performance of the VLC link using CMOS camera for different LED luminaires for the first time in our knowledge. Experimental evaluation to compare their bit-error-rate (BER) performances and demodulation are also performed, and it can be summarized that just need to change the LED luminaire with more uniformity light output, the blooming effect would not exist; which not only can reduce the complexity of the demodulation but also enhance the communication quality. In addition, we propose and demonstrate to use contrast limited adaptive histogram equalization to extend the transmission distance and mitigate the influence of the background noise. And the experimental results show that the BER can be decreased by an order of magnitude by using the proposed method.

  13. Luminescence properties after X-ray irradiation for dosimetry

    NASA Astrophysics Data System (ADS)

    Hong, Duk-Geun; Kim, Myung-Jin

    2016-05-01

    To investigate the luminescence characteristics after exposure to X-ray radiation, we developed an independent, small X-ray irradiation system comprising a Varian VF-50J mini X-ray generator, a Pb collimator, a delay shutter, and an Al absorber. With this system, the apparent dose rate increased linearly to 0.8 Gy/s against the emission current for a 50 kV anode potential when the shutter was delayed for an initial 4 s and the Al absorber was 300 µm thick. In addition, an approximately 20 mm diameter sample area was irradiated homogeneously with X rays. Based on three-dimensional (3D) thermoluminescence (TL) spectra, the small X-ray irradiator was considered comparable to the conventional 90Sr/90Y beta source even though the TL intensity from beta irradiation was higher than that from X-ray irradiation. The single aliquot regenerative (SAR) growth curve for the small X-ray irradiator was identical to that for the beta source. Therefore, we concluded that the characteristics of the small X-ray irradiator and the conventional 90Sr/90Y beta source were similar and that X ray irradiation had the potential for being suitable for use in luminescence dosimetry.

  14. Effect of Illumination on Ocular Status Modifications Induced by Short-Term 3D TV Viewing

    PubMed Central

    Chen, Yuanyuan; Xu, Aiqin; Jiang, Jian

    2017-01-01

    Objectives. This study aimed to compare changes in ocular status after 3D TV viewing under three modes of illumination and thereby identify optimal illumination for 3D TV viewing. Methods. The following measures of ocular status were assessed: the accommodative response, accommodative microfluctuation, accommodative facility, relative accommodation, gradient accommodative convergence/accommodation (AC/A) ratio, phoria, and fusional vergence. The observers watched 3D television for 90 minutes through 3D shutter glasses under three illumination modes: A, complete darkness; B, back illumination (50 lx); and C, front illumination (130 lx). The ocular status of the observers was assessed both before and after the viewing. Results. After 3D TV viewing, the accommodative response and accommodative microfluctuation were significantly changed under illumination Modes A and B. The near positive fusional vergence decreased significantly after the 90-minute 3D viewing session under each illumination mode, and this effect was not significantly different among the three modes. Conclusions. Short-term 3D viewing modified the ocular status of adults. The least amount of such change occurred with front illumination, suggesting that this type of illumination is an appropriate mode for 3D shutter TV viewing. PMID:28348893

  15. Development of arrays of position-sensitive microcalorimeters for Constellation-X

    NASA Technical Reports Server (NTRS)

    Smith, S. J.; Bandler, S. R.; Brekosky, R. P.; Brown, A.-D.; Chervenak, J. A.; Eckart, M. E.; Finkbeiner, F. M.; Iyomoto, N.; Kelley, R. L.; Kolbourne, C. A.; hide

    2008-01-01

    We are developing arrays of position-sensitive transition-edge sensor (POST) X-ray detectors for future astronomy missions such as NASA's Constellation-X. The POST consists of multiple absorbers thermally coupled to one or more transition-edge sensor (TES). Each absorber element has a different thermal coupling to the TES. This results in a distribution of different pulse shapes and enables position discrimination between the absorber elements. POST'S are motivated by the desire to achieve the largest possible focal plane area with the fewest number of readout channels and are ideally suited to increasing the Constellation-X focal plane area, without comprising on spatial sampling. Optimizing the performance of POST'S requires careful design of key parameters such as the thermal conductances between the absorbers, TES and the heat sink. as well as the absorber heat capacities. Using recently developed signal processing algorithms we have investigated the trade-off between position-sensitivity, energy resolution and pulse decay time. based on different device design parameters for PoST's. Our new generation of PoST's utilize technology successfully developed on high resolution (approximately 2.5eV) single pixels arrays of Mo/Au TESs. also under development for Constellation-X. This includes noise mitigation features on the TES and low resistivity electroplated absorbers. We report on the first experimental results from these new one and two-channel PoST"s, consisting of all Au and composite Au/Bi absorbers, which are designed to achieve an energy resolution of < 10 eV. coupled with count-rates of 100's per pixel per second and position sensitivity over the energy range 0.3-10 keV.

  16. The Fermi-LAT detection of magnetar-like pulsar PSR J1846-0258 at high-energy gamma-rays

    NASA Astrophysics Data System (ADS)

    Kuiper, L.; Hermsen, W.; Dekker, A.

    2018-03-01

    We report the detection of the pulsed signal of the radio-quiet magnetar-like pulsar PSR J1846-0258 in the high-energy γ-ray data of the Fermi Large Area Telescope (Fermi LAT). We produced phase-coherent timing models exploiting RXTE PCA and Swift XRT monitoring data for the post- (magnetar-like) outburst period from 2007 August 28 to 2016 September 4, with independent verification using INTEGRAL ISGRI and Fermi GBM data. Phase-folding barycentric arrival times of selected Fermi LAT events from PSR J1846-0258 resulted in a 4.2σ detection (30-100 MeV) of a broad pulse consistent in shape and aligned in phase with the profiles that we measured with Swift XRT (2.5-10 keV), INTEGRAL ISGRI (20-150 keV), and Fermi GBM (20-300 keV). The pulsed flux (30-100 MeV) is (3.91 ± 0.97) × 10-9 photons cm-2 s-1 MeV-1. Declining significances of the INTEGRAL ISGRI 20-150 keV pulse profiles suggest fading of the pulsed hard X-ray emission during the post-outburst epochs. We revisited with greatly improved statistics the timing and spectral characteristics of PSR B1509-58 as measured with the Fermi LAT. The broad-band pulsed emission spectra (from 2 keV up to GeV energies) of PSR J1846-0258 and PSR B1509-58 can be accurately described with similarly curved shapes, with maximum luminosities at 3.5 ± 1.1 MeV (PSR J1846-0258) and 2.23 ± 0.11 MeV (PSR B1509-58). We discuss possible explanations for observational differences between Fermi LAT detected pulsars that reach maximum luminosities at GeV energies, like the second magnetar-like pulsar PSR J1119-6127, and pulsars with maximum luminosities at MeV energies, which might be due to geometric differences rather than exotic physics in high-B fields.

  17. Effect of sex on wasted left ventricular effort following maximal exercise.

    PubMed

    Lane, A D; Ranadive, S M; Yan, H; Kappus, R M; Cook, M D; Sun, P; Woods, J A; Wilund, K; Fernhall, B

    2013-09-01

    Wasted left ventricular effort (∆Ew) refers to work required of the left ventricle to eject blood that does not result in increased stroke volume and is related to left ventricular hypertrophy. Literature shows that men and women have differing ventricular and vascular responses to and following exercise. Our purpose was to determine how ∆Ew changes post-exercise in men and women and examine potential mechanisms. We hypothesized a reduction in ∆Ew that would be greater in men and that central pulse wave velocity and wave intensity (WIA) would be related to ∆Ew. Blood pressures, central pulse wave velocity (cPWV), and WIA were obtained at rest, 15 and 30 min after maximal exercise. Both sexes reduced ∆Ew post-maximal exercise (p>0.05 for interaction), but women had higher ∆Ew at each time point (p<0.05). The first peak of WIA increased 15 min post-exercise only in women (p<0.05). cPWV was attenuated (p<0.05) in women at 15 min and men at 30 min (p<0.05) post-exercise with a significant time by sex interaction (p<0.05). WIA (1st peak) was correlated (p<0.05) to ∆Ew in both sexes before and 15 min post-exercise, but cPWV was only associated with ∆Ew in men at 30 min post-exercise. We conclude that both sexes decrease ∆Ew after maximal exercise, but vascular and ventricular changes associated with the attenuation of ∆Ew are not uniform between sexes. © Georg Thieme Verlag KG Stuttgart · New York.

  18. X-band EPR setup with THz light excitation of Novosibirsk Free Electron Laser: Goals, means, useful extras

    NASA Astrophysics Data System (ADS)

    Veber, Sergey L.; Tumanov, Sergey V.; Fursova, Elena Yu.; Shevchenko, Oleg A.; Getmanov, Yaroslav V.; Scheglov, Mikhail A.; Kubarev, Vitaly V.; Shevchenko, Daria A.; Gorbachev, Iaroslav I.; Salikova, Tatiana V.; Kulipanov, Gennady N.; Ovcharenko, Victor I.; Fedin, Matvey V.

    2018-03-01

    Electron Paramagnetic Resonance (EPR) station at the Novosibirsk Free Electron Laser (NovoFEL) user facility is described. It is based on X-band (∼9 GHz) EPR spectrometer and operates in both Continuous Wave (CW) and Time-Resolved (TR) modes, each allowing detection of either direct or indirect influence of high-power NovoFEL light (THz and mid-IR) on the spin system under study. The optics components including two parabolic mirrors, shutters, optical chopper and multimodal waveguide allow the light of NovoFEL to be directly fed into the EPR resonator. Characteristics of the NovoFEL radiation, the transmission and polarization-retaining properties of the waveguide used in EPR experiments are presented. The types of proposed experiments accessible using this setup are sketched. In most practical cases the high-power radiation applied to the sample induces its rapid temperature increase (T-jump), which is best visible in TR mode. Although such influence is a by-product of THz radiation, this thermal effect is controllable and can deliberately be used to induce and measure transient signals of arbitrary samples. The advantage of tunable THz radiation is the absence of photo-induced processes in the sample and its high penetration ability, allowing fast heating of a large portion of virtually any sample and inducing intense transients. Such T-jump TR EPR spectroscopy with THz pulses has been previewed for the two test samples, being a useful supplement for the main goals of the created setup.

  19. Ring-Gaussian laser pulse filamentation in a self-induced diffraction waveguide

    NASA Astrophysics Data System (ADS)

    Geints, Yu E.; Zemlyanov, A. A.

    2017-10-01

    Self-action in air of a high-power femtosecond laser pulse with the spatial form of a ring-Gaussian beam (‘dressed’ beam) is studied theoretically. Pulse self-focusing and filamentation is analyzed in detail through the numerical solution of the spectral propagation equation, taking into account medium optical nonlinearity and plasma generation. Pulse propagation dynamics and energy fluxes inside the beam are visualized by means of averaged diffraction ray tracing. We clearly show that, in terms of diffraction optics, the outer ring forms a specific nonmaterial diffractive waveguide, favoring long-range self-channeling of the central part of a beam by delivering optical energy to a filament. The spatial robustness and stability of such diffractive waveguides strongly depends on the energy stored in the ring, as well as on its position relative to the beam axis. The striking advantage of such ‘dressed’ beams is their reduced angular divergence during plasma-free (post-filamentation) evolution.

  20. Detection of rebars in concrete using advanced ultrasonic pulse compression techniques.

    PubMed

    Laureti, S; Ricci, M; Mohamed, M N I B; Senni, L; Davis, L A J; Hutchins, D A

    2018-04-01

    A pulse compression technique has been developed for the non-destructive testing of concrete samples. Scattering of signals from aggregate has historically been a problem in such measurements. Here, it is shown that a combination of piezocomposite transducers, pulse compression and post processing can lead to good images of a reinforcement bar at a cover depth of 55 mm. This has been achieved using a combination of wide bandwidth operation over the 150-450 kHz range, and processing based on measuring the cumulative energy scattered back to the receiver. Results are presented in the form of images of a 20 mm rebar embedded within a sample containing 10 mm aggregate. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Using laser-induced breakdown spectroscopy on vacuum alloys-production process for elements concentration analysis

    NASA Astrophysics Data System (ADS)

    Zhao, Tianzhuo; Fan, Zhongwei; Lian, Fuqiang; Liu, Yang; Lin, Weiran; Mo, Zeqiang; Nie, Shuzhen; Wang, Pu; Xiao, Hong; Li, Xin; Zhong, Qixiu; Zhang, Hongbo

    2017-11-01

    Laser-induced breakdown spectroscopy (LIBS) utilizing an echelle spectrograph-ICCD system is employed for on-line analysis of elements concentration in a vacuum induction melting workshop. Active temperature stabilization of echelle spectrometer is implemented specially for industrial environment applications. The measurement precision is further improved by monitoring laser parameters, such as pulse energy, spatial and temporal profiles, in real time, and post-selecting laser pulses with specific pulse energies. Experimental results show that major components of nickel-based alloys are stable, and can be well detected. By using internal standard method, calibration curves for chromium and aluminum are obtained for quantitative determination, with determination coefficient (relative standard deviation) to be 0.9559 (< 2.2%) and 0.9723 (< 2.8%), respectively.

  2. Fundamental Study of Three-dimensional Fast Spin-echo Imaging with Spoiled Equilibrium Pulse.

    PubMed

    Ogawa, Masashi; Kaji, Naoto; Tsuchihashi, Toshio

    2017-01-01

    Three-dimensional fast spin-echo (3D FSE) imaging with variable refocusing flip angle has been recently applied to pre- or post-enhanced T 1 -weighted imaging. To reduce the acquisition time, this sequence requires higher echo train length (ETL), which potentially causes decreased T 1 contrast. Spoiled equilibrium (SpE) pulse consists of a resonant +90° radiofrequency (RF) pulse and is applied at the end of the echo train. This +90° RF pulse brings residual transverse magnetization to the negative longitudinal axis, which makes it possible to increase T 1 contrast. The purpose of our present study was to examine factors that influence the effect of spoiled equilibrium pulse and the relationship between T 1 contrast improvement and imaging parameters and to understand the characteristics of spoiled equilibrium pulse. Phantom studies were conducted using an magnetic resonance imaging (MRI) phantom made of polyvinyl alcohol gel. To evaluate the effect of spoiled equilibrium pulse with changes in repetition time (TR), ETL, and refocusing flip angle, we measured the signal-to-noise ratio and contrast-to-noise ratio (CNR). The effect of spoiled equilibrium pulse was evaluated by calculating the enhancement rate of CNR. The factors that influence the effect of spoiled equilibrium pulse are TR, ETL, and relaxation time of tissues. Spoiled equilibrium pulse is effective with increasing TR and decreasing ETL. The shorter the T 1 value, the better the spoiled equilibrium pulse functions. However, for tissues in which the T 1 value is long (>600 ms), at a TR of 600 ms, improvement in T 1 contrast by applying spoiled equilibrium pulse cannot be expected.

  3. Concerted manipulation of laser plasma dynamics with two laser pulses

    NASA Astrophysics Data System (ADS)

    Braenzel, J.; Andreev, A. A.; Ehrentraut, L.; Sommer, D.; Schnürer, M.

    2017-05-01

    In this article we present experimental results from a counter-propagating two laser pulse experiment at high intensity and using ultrathin gold and plastic foil targets. We applied one laser pulse as a pre-pulse with an intensity of up to 1x1018 W/cm2. By this method we manipulated the pre-plasma of the foil target with which the stronger laser pulse with an intensity of 6x1019W/cm2 interacts. This alters significantly subsequent processes from the laser plasma interaction which we show the ion acceleration and high harmonic generation. On the one hand, the maximum kinetic ion energy and the maximum charge state for gold ions decline due to the pre-heating of the target in the time range of few ps, on the other hand the number of accelerated ions is increased. For the same parameter range we detected a significant raise of the high harmonic emission. Moreover, we present first experimental observations, that when the second laser pulse is applied as a counter-propagating post-pulse the energy distribution of accelerated carbon ions is charge selective altered. Our findings indicate that using this method a parametric optimization can be achieved, which promises new insights about the concurrent processes of the laser plasma dynamics.

  4. Burst stimulation improves hemodynamics during resuscitation after prolonged ventricular fibrillation.

    PubMed

    Walcott, Gregory; Melnick, Sharon; Killingsworth, Cheryl; Ideker, Raymond

    2009-02-01

    Although return of spontaneous circulation (ROSC) is frequently achieved during resuscitation for sudden cardiac arrest, systolic blood pressure can then decrease, requiring additional myocardial support. Previous studies have shown that a series of 1-ms electrical pulses delivered through the defibrillation patches during ventricular fibrillation (VF) can stimulate the autonomic nervous system to increase myocardial function following defibrillation. We hypothesized that a similar series of electrical pulses could increase myocardial function and blood pressure during the early post-resuscitation period. Six swine were studied that underwent 6-7 min. Each animal received 5, 10, 15, or 20 pulse packets consisting of 6 10 A, 1-ms pulses every 3-4 s in random order whenever systolic blood pressure became less than 50 mmHg. All four sets of pulse packets were delivered to each animal. Systolic blood pressure and cardiac function (left ventricular +dP/dt) were increased to pre-stimulation levels or above by all four sets of pulse packets. The increases were significantly greater for the longer than the shorter number of pulse packets. The mean+/-SD duration of the time that the systolic pressure remained above 50 mmHg following pulse delivery was 4.2+/-2.5 min. Electrical stimulation during regular rhythm following prolonged VF and resuscitation can increase blood pressure and cardiac function to above prestimulation levels.

  5. Burst Stimulation Improves Hemodynamics During Resuscitation after Prolonged Ventricular Fibrillation

    PubMed Central

    Walcott, Gregory; Melnick, Sharon; Killingsworth, Cheryl; Ideker, Raymond

    2009-01-01

    Background Although return of spontaneous circulation (ROSC) is frequently achieved during resuscitation for sudden cardiac arrest, systolic blood pressure can then decrease, requiring additional myocardial support. Previous studies have shown that a series of 1-ms electrical pulses delivered through the defibrillation patches during ventricular fibrillation (VF) can stimulate the autonomic nervous system to increase myocardial function following defibrillation. We hypothesized that a similar series of electrical pulses could increase myocardial function and blood pressure during the early post-resuscitation period. Methods and Results Six swine were studied that underwent 6–7 min. Each animal received 5, 10, 15, or 20 pulse packets consisting of 6 10 A, 1-ms pulses every 3–4 s in random order whenever systolic blood pressure became less than 50 mmHg. All four sets of pulse packets were delivered to each animal. Systolic blood pressure and cardiac function (left ventricular +dP/dt) were increased to pre-stimulation levels or above by all four sets of pulse packets. The increases were significantly greater for the longer than the shorter number of pulse packets. The mean±SD duration of the time that the systolic pressure remained above 50 mmHg following pulse delivery was 4.2±2.5 min. Conclusions Electrical stimulation during regular rhythm following prolonged VF and resuscitation can increase blood pressure and cardiac function to above pre-arrest levels. PMID:19655042

  6. First principles pulse pile-up balance equation and fast deterministic solution

    NASA Astrophysics Data System (ADS)

    Sabbatucci, Lorenzo; Fernández, Jorge E.

    2017-08-01

    Pulse pile-up (PPU) is an always present effect which introduces a distortion into the spectrum measured with radiation detectors and that worsen with the increasing emission rate of the radiation source. It is fully ascribable to the pulse handling circuitry of the detector and it is not comprised in the detector response function which is well explained by a physical model. The PPU changes both the number and the height of the recorded pulses, which are related, respectively, with the number of detected particles and their energy. In the present work, it is derived a first principles balance equation for second order PPU to obtain a post-processing correction to apply to X-ray measurements. The balance equation is solved for the particular case of rectangular pulse shape using a deterministic iterative procedure for which it will be shown the convergence. The proposed method, deterministic rectangular PPU (DRPPU), requires minimum amount of information and, as example, it is applied to a solid state Si detector with active or off-line PPU suppression circuitry. A comparison shows that the results obtained with this fast and simple approach are comparable to those from the more sophisticated procedure using precise detector pulse shapes.

  7. A near-infrared SETI experiment: A multi-time resolution data analysis

    NASA Astrophysics Data System (ADS)

    Tallis, Melisa; Maire, Jerome; Wright, Shelley; Drake, Frank D.; Duenas, Andres; Marcy, Geoffrey W.; Stone, Remington P. S.; Treffers, Richard R.; Werthimer, Dan; NIROSETI

    2016-06-01

    We present new post-processing routines which are used to detect very fast optical and near-infrared pulsed signals using the latest NIROSETI (Near-Infrared Optical Search for Extraterrestrial Intelligence) instrument. NIROSETI was commissioned in 2015 at Lick Observatory and searches for near-infrared (0.95 to 1.65μ) nanosecond pulsed laser signals transmitted by distant civilizations. Traditional optical SETI searches rely on analysis of coincidences that occur between multiple detectors at a fixed time resolution. We present a multi-time resolution data analysis that extends our search from the 1ns to 1ms range. This new feature greatly improves the versatility of the instrument and its search parameters for near-infrared SETI. We aim to use these algorithms to assist us in our search for signals that have varying duty cycles and pulse widths. We tested the fidelity and robustness of our algorithms using both synthetic embedded pulsed signals, as well as data from a near-infrared pulsed laser installed on the instrument. Applications of NIROSETI are widespread in time domain astrophysics, especially for high time resolution transients, and astronomical objects that emit short-duration high-energy pulses such as pulsars.

  8. Pinhole Cameras: For Science, Art, and Fun!

    ERIC Educational Resources Information Center

    Button, Clare

    2007-01-01

    A pinhole camera is a camera without a lens. A tiny hole replaces the lens, and light is allowed to come in for short amount of time by means of a hand-operated shutter. The pinhole allows only a very narrow beam of light to enter, which reduces confusion due to scattered light on the film. This results in an image that is focused, reversed, and…

  9. Apollo 8 Mission image

    NASA Image and Video Library

    1968-12-21

    Apollo 8,Moon, Latitude 15 degrees South,Longitude 170 degrees West. Camera Tilt Mode: High Oblique. Direction: Southeast. Sun Angle 17 degrees. Original Film Magazine was labeled E. Camera Data: 70mm Hasselblad; F-Stop: F-5.6; Shutter Speed: 1/250 second. Film Type: Kodak SO-3400 Black and White,ASA 40. Other Photographic Coverage: Lunar Orbiter 1 (LO I) S-3. Flight Date: December 21-27,1968.

  10. CMOS Active Pixel Sensor Star Tracker with Regional Electronic Shutter

    NASA Technical Reports Server (NTRS)

    Yadid-Pecht, Orly; Pain, Bedabrata; Staller, Craig; Clark, Christopher; Fossum, Eric

    1996-01-01

    The guidance system in a spacecraft determines spacecraft attitude by matching an observed star field to a star catalog....An APS(active pixel sensor)-based system can reduce mass and power consumption and radiation effects compared to a CCD(charge-coupled device)-based system...This paper reports an APS (active pixel sensor) with locally variable times, achieved through individual pixel reset (IPR).

  11. System for beaming power from earth to a high altitude platform

    DOEpatents

    Friedman, Herbert W.; Porter, Terry J.

    2002-01-01

    Power is transmitted to a high altitude platform by an array of diode pumped solid state lasers each operated at a single range of laser wavelengths outside of infrared and without using adaptive optics. Each laser produces a beam with a desired arrival spot size. An aircraft avoidance system uses a radar system for automatic control of the shutters of the lasers.

  12. Dosimetry in Thermal Neutron Irradiation Facility at BMRR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, J. P.; Holden, N. E.; Reciniello, R. N.

    Radiation dosimetry for Neutron Capture Therapy (NCT) has been performed since 1959 at Thermal Neutron Irradiation Facility (TNIF) of the three-megawatt light-water cooled Brookhaven Medical Research Reactor (BMRR). In the early 1990s when more effective drug carriers were developed for NCT, in which the eye melanoma and brain tumors in rats were irradiated in situ, extensive clinical trials of small animals began using a focused thermal neutron beam. To improve the dosimetry at irradiation facility, a series of innovative designs and major modifications made to enhance the beam intensity and to ease the experimental sampling at BMRR were performed; includingmore » (1) in-core fuel addition to increase source strength and balance flux of neutrons towards two ports, (2) out of core moderator remodeling, done by replacing thicker D 2O tanks at graphite-shutter interfacial areas, to expedite neutron thermalization, (3) beam shutter upgrade to reduce strayed neutrons and gamma dose, (4) beam collimator redesign to optimize the beam flux versus dose for animal treatment, (5) beam port shielding installation around the shutter opening area (lithium-6 enriched polyester-resin in boxes, attached with polyethylene plates) to reduce prompt gamma and fast neutron doses, (6) sample holder repositioning to optimize angle versus distance for a single organ or whole body irradiation, and (7) holder wall buildup with neutron reflector materials to increase dose and dose rate from scattered thermal neutrons. During the facility upgrade, reactor dosimetry was conducted using thermoluminescent dosimeters TLD for gamma dose estimate, using ion chambers to confirm fast neutron and gamma dose rate, and by the activation of gold-foils with and without cadmium-covers, for fast and thermal neutron flux determination. Based on the combined effect from the size and depth of tumor cells and the location and geometry of dosimeters, the measured flux from cadmium-difference method was 4 - 7 % lower than the statistical mean derived from the Monte-Carlo modeling (5% uncertainty). The dose rate measured by ion chambers was 6 - 10 % lower than the output tallies (7% uncertainty). The detailed dosimetry that was performed at the TNIF for the NCT will be described.« less

  13. Dosimetry in Thermal Neutron Irradiation Facility at BMRR

    NASA Astrophysics Data System (ADS)

    Hu, J.-P.; Holden, N. E.; Reciniello, R. N.

    2016-02-01

    Radiation dosimetry for Neutron Capture Therapy (NCT) has been performed since 1959 at Thermal Neutron Irradiation Facility (TNIF) of the three-megawatt light-water cooled Brookhaven Medical Research Reactor (BMRR). In the early 1990s when more effective drug carriers were developed for NCT, in which the eye melanoma and brain tumors in rats were irradiated in situ, extensive clinical trials of small animals began using a focused thermal neutron beam. To improve the dosimetry at irradiation facility, a series of innovative designs and major modifications made to enhance the beam intensity and to ease the experimental sampling at BMRR were performed; including (1) in-core fuel addition to increase source strength and balance flux of neutrons towards two ports, (2) out of core moderator remodeling, done by replacing thicker D2O tanks at graphite-shutter interfacial areas, to expedite neutron thermalization, (3) beam shutter upgrade to reduce strayed neutrons and gamma dose, (4) beam collimator redesign to optimize the beam flux versus dose for animal treatment, (5) beam port shielding installation around the shutter opening area (lithium-6 enriched polyester-resin in boxes, attached with polyethylene plates) to reduce prompt gamma and fast neutron doses, (6) sample holder repositioning to optimize angle versus distance for a single organ or whole body irradiation, and (7) holder wall buildup with neutron reflector materials to increase dose and dose rate from scattered thermal neutrons. During the facility upgrade, reactor dosimetry was conducted using thermoluminescent dosimeters TLD for gamma dose estimate, using ion chambers to confirm fast neutron and gamma dose rate, and by the activation of gold-foils with and without cadmium-covers, for fast and thermal neutron flux determination. Based on the combined effect from the size and depth of tumor cells and the location and geometry of dosimeters, the measured flux from cadmium-difference method was 4-7% lower than the statistical mean derived from the Monte-Carlo modeling (5% uncertainty). The dose rate measured by ion chambers was 6-10% lower than the output tallies (7% uncertainty). The detailed dosimetry that was performed at the TNIF for the NCT will be described.

  14. Laser printed plasmonic color metasurfaces (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Kristensen, Anders; Zhu, Xiaolong; Højlund-Nielsen, Emil; Vannahme, Christoph; Mortensen, N. Asger

    2016-09-01

    This paper describes color printing on nanoimprinted plasmonic metasurfaces by laser post-writing, for flexible decoration of high volume manufactured plastic products. Laser pulses induce transient local heat generation that leads to melting and reshaping of the imprinted nanostructures. Different surface morphologies that support different plasmonic resonances, and thereby different color appearances, are created by control of the laser pulse energy density. All primary colors can be printed, with a speed of 1 ns per pixel, resolution up to 127,000 dots per inch (DPI) and power consumption down to 0.3 nJ per pixel.

  15. Spatio-temporal characterisation of a 100 kHz 24 W sub-3-cycle NOPCPA laser system

    NASA Astrophysics Data System (ADS)

    Witting, Tobias; Furch, Federico J.; Vrakking, Marc J. J.

    2018-04-01

    In recent years, OPCPA and NOPCPA laser systems have shown the potential to supersede Ti:sapphire plus post-compression based laser systems to drive next generation attosecond light sources via direct amplification of few-cycle pulses to high pulse energies at high repetition rates. In this paper, we present a sub 3-cycle, 100 kHz, 24 W NOPA laser system and characterise its spatio-temporal properties using the SEA-F-SPIDER technique. Our results underline the importance of spatio-temporal diagnostics for these emerging laser systems.

  16. Research on range-gated laser active imaging seeker

    NASA Astrophysics Data System (ADS)

    You, Mu; Wang, PengHui; Tan, DongJie

    2013-09-01

    Compared with other imaging methods such as millimeter wave imaging, infrared imaging and visible light imaging, laser imaging provides both a 2-D array of reflected intensity data as well as 2-D array of range data, which is the most important data for use in autonomous target acquisition .In terms of application, it can be widely used in military fields such as radar, guidance and fuse. In this paper, we present a laser active imaging seeker system based on range-gated laser transmitter and sensor technology .The seeker system presented here consist of two important part, one is laser image system, which uses a negative lens to diverge the light from a pulse laser to flood illuminate a target, return light is collected by a camera lens, each laser pulse triggers the camera delay and shutter. The other is stabilization gimbals, which is designed to be a rotatable structure both in azimuth and elevation angles. The laser image system consists of transmitter and receiver. The transmitter is based on diode pumped solid-state lasers that are passively Q-switched at 532nm wavelength. A visible wavelength was chosen because the receiver uses a Gen III image intensifier tube with a spectral sensitivity limited to wavelengths less than 900nm.The receiver is image intensifier tube's micro channel plate coupled into high sensitivity charge coupled device camera. The image has been taken at range over one kilometer and can be taken at much longer range in better weather. Image frame frequency can be changed according to requirement of guidance with modifiable range gate, The instantaneous field of views of the system was found to be 2×2 deg. Since completion of system integration, the seeker system has gone through a series of tests both in the lab and in the outdoor field. Two different kinds of buildings have been chosen as target, which is located at range from 200m up to 1000m.To simulate dynamic process of range change between missile and target, the seeker system has been placed on the truck vehicle running along the road in an expected speed. The test result shows qualified image and good performance of the seeker system.

  17. Northern California LIDAR Data: A Tool for Mapping the San Andreas Fault and Pleistocene Marine Terraces in Heavily Vegetated Terrain

    NASA Astrophysics Data System (ADS)

    Prentice, C. S.; Crosby, C. J.; Harding, D. J.; Haugerud, R. A.; Merritts, D. J.; Gardner, T. W.; Koehler, R. D.; Baldwin, J. N.

    2003-12-01

    Recent acquisition of airborne LIDAR (also known as ALSM) data covering approximately 418 square kilometers of coastal northern California provides a powerful new tool for mapping geomorphic features related to the San Andreas Fault and coastal uplift. LIDAR data has been previously used in the Puget Lowland region of Washington to identify and map Holocene faults and uplifted shorelines concealed under dense vegetation (Haugerud et al., 2003; see http://pugetsoundlidar.org). Our effort represents the first use of LIDAR data for this purpose along the San Andreas Fault. This data set is the result of a collaborative effort between NASA Solid Earth and Natural Hazards Program, Goddard Space Flight Center, Stennis Space Center, USGS, and TerraPoint, LLC. The coverage extends from near Fort Ross, California, in Sonoma County, along the coast northward to the town of Mendocino, in Mendocino County, and as far inland as about 1-3 km east of the San Andreas Fault. The survey area includes about 70 km of the northern San Andreas Fault under dense redwood forest, and Pleistocene coastal marine terraces both north and south of the fault. The average data density is two laser pulses per square meter, with up to four LIDAR returns per pulse. Returns are classified as ground or vegetation, allowing construction of both canopy-top and bare-earth DEMs with 1.8m grid spacing. Vertical accuracy is better than 20 cm RMSE, confirmed by a network of ground-control points established using high-precision GPS surveying. We are using hillshade images generated from the bare-earth DEMs to begin detailed mapping of geomorphic features associated with San Andreas Fault traces, such as scarps, offset streams, linear valleys, shutter ridges, and sag ponds. In addition, we are using these data in conjunction with field mapping and interpretation of conventional 1:12,000 and 1:6000 scale aerial photographs to map and correlate marine terraces to better understand rates of coastal uplift, and rates of strike-slip motion across the San Andreas Fault.

  18. A prospective study analyzing the application of radiofrequency energy and high-voltage, ultrashort pulse duration electrical fields on the quantitative reduction of adipose tissue

    PubMed Central

    Duncan, Diane Irvine; Kim, Theresa H. M.; Temaat, Robbin

    2016-01-01

    Noninvasive fat reduction is claimed by many device manufacturers, but proof of efficacy has been difficult to establish. This prospective study was designed to measure the reduction of fat thickness and actual volume reduction in 20 female patients treated with an external radiofrequency (RF) device. This device combines RF heat, suction coupled vacuum, and oscillating electrical pulses that induce adipocyte death over time. Patients underwent pre- and post-treatment and intercurrent measurements of weight, body mass index, ultrasonic transcutaneous fat thickness, and 2D and 3D Vectra photography with independent calculation of circumferential and volumetric change. Mean transcutaneous ultrasound thickness at reproducible points was 2.78 cm; at 1-month post-treatment, the mean fat thickness was 1.71 cm. At 3-month post-treatment, the mean fat thickness reduction was 39.6%. Vectra circumference measurements were taken at 10-mm intervals, with postural and breathing cycle control. Independent analysis of serial measurements from + 60 to − 70 mm showed mean abdominal circumference measurement of 2.3 cm. Mean abdominal volume loss was 202.4 and 428.5 cc at 1- and 3-month post-treatment, respectively. Scanning electron microscopy confirmed that permanent cell destruction was caused by irreversible electroporation. Pyroptosis appears to be the mechanism of action. PMID:26962636

  19. A prospective study analyzing the application of radiofrequency energy and high-voltage, ultrashort pulse duration electrical fields on the quantitative reduction of adipose tissue.

    PubMed

    Duncan, Diane Irvine; Kim, Theresa H M; Temaat, Robbin

    2016-10-01

    Noninvasive fat reduction is claimed by many device manufacturers, but proof of efficacy has been difficult to establish. This prospective study was designed to measure the reduction of fat thickness and actual volume reduction in 20 female patients treated with an external radiofrequency (RF) device. This device combines RF heat, suction coupled vacuum, and oscillating electrical pulses that induce adipocyte death over time. Patients underwent pre- and post-treatment and intercurrent measurements of weight, body mass index, ultrasonic transcutaneous fat thickness, and 2D and 3D Vectra photography with independent calculation of circumferential and volumetric change. Mean transcutaneous ultrasound thickness at reproducible points was 2.78 cm; at 1-month post-treatment, the mean fat thickness was 1.71 cm. At 3-month post-treatment, the mean fat thickness reduction was 39.6%. Vectra circumference measurements were taken at 10-mm intervals, with postural and breathing cycle control. Independent analysis of serial measurements from + 60 to - 70 mm showed mean abdominal circumference measurement of 2.3 cm. Mean abdominal volume loss was 202.4 and 428.5 cc at 1- and 3-month post-treatment, respectively. Scanning electron microscopy confirmed that permanent cell destruction was caused by irreversible electroporation. Pyroptosis appears to be the mechanism of action.

  20. Laser-induced scleral shrinkage for refractive surgery

    NASA Astrophysics Data System (ADS)

    Ren, Qiushi; Simon, Gabriel; Parel, Jean-Marie A.; Shen, Jin-Hui

    1994-06-01

    We investigate the laser refractive scleroplasty (LRS) as a potential minimal-invasive method for correcting post-operative astigmatism. The scleral shrinkage near limbus was induced on 6 cadaver eyes using a 200 micrometers fiber optic probe coupled to a pulsed Ho:YAG laser. The diameter of the treatment spot was 0.8 mm. The output energy measured at tip was 60.2+/- 0.6 mJ. The treatments consisted of multiple sector patterns placed along the major axis of astigmatism parallel to the limbus, and round patterns placed along the limbus. Three treatment spots were applied on each side of the sector. The separation among sectors and limbus is 1 mm. Keratometry and topography of the cornea were measured after each sector or round pattern treatment. Effect of 5 and 10 pulses at each treatment spot were compared. Histology was performed to evaluate laser tissue damage. The major axis of astigmatism was shifted 90 degrees after the sector pattern treatment and amount of dioptric change increased when adding a new treatment or using more treatment pulses. However, the spherical equivalent of the eyes was essentially unchanged. The keratometry of the corneas remained the same after the round pattern treatment. Laser refractive scleroplasty may be applied for the correction of post-operative astigmatism.

  1. Dynamic Responses of Intact Post Mortem Human Surrogates from Inferior-to-Superior Loading at the Pelvis.

    PubMed

    Yoganandan, Narayan; Moore, Jason; Arun, Mike W J; Pintar, Frank A

    2014-11-01

    During certain events such as underbody blasts due to improvised explosive devices, occupants in military vehicles are exposed to inferior-to-superior loading from the pelvis. Injuries to the pelvis-sacrum-lumbar spine complex have been reported from these events. The mechanism of load transmission and potential variables defining the migration of injuries between pelvis and or spinal structures are not defined. This study applied inferior-to-superior impacts to the tuberosities of the ischium of supine-positioned five post mortem human subjects (PMHS) using different acceleration profiles, defined using shape, magnitude and duration parameters. Seventeen tests were conducted. Overlay temporal plots were presented for normalized (impulse momentum approach) forces and accelerations of the sacrum and spine. Scatter plots showing injury and non-injury data as a function of peak normalized forces, pulse characteristics, impulse and power, loading rate and sacrum and spine accelerations were evaluated as potential metrics related to pathological outcomes with the focus of examining the role of the pulse characteristics from inferior-to-superior loading of the pelvis-sacrum-lumbar spine complex. Interrelationships were explored between non-fracture and fracture outcomes, and fracture patterns with a focus on migration of injuries from the hip-only to hip and spine to spine-only regions. Observations indicate that injury to the pelvis and or spine from inferior-to-superior loading is associated with pulse and not just peak velocity. The role of the effect of mass recruitment and injury migration parallel knee-thigh-hip complex studies, suggest a wider application of the recruitment concept and the role of the pulse characteristics.

  2. Registration of Large Motion Blurred Images

    DTIC Science & Technology

    2016-05-09

    in handling the dynamics of the capturing system, for example, a drone. CMOS sensors , used in recent times, when employed in these cameras produce...handling the dynamics of the capturing system, for example, a drone. CMOS sensors , used in recent times, when employed in these cameras produce two types...blur in the captured image when there is camera motion during exposure. However, contemporary CMOS sensors employ an electronic rolling shutter (RS

  3. Utilizing Microelectromechanical Systems (MEMS) Micro-Shutter Designs for Adaptive Coded Aperture Imaging (ACAI) Technologies

    DTIC Science & Technology

    2009-03-01

    52 Figure 4-1: Applied voltage versus deflection curve for Poly1/Poly2 stacked 300-μm single hot-arm actuator (shown on right...58 Figure 4-2: Applied voltage versus deflection curve for Poly1/Poly2 stacked 300-μm double hot-arm actuator (shown on...61 Figure 4-5: Deflection vs. power curves for an individual wedge from

  4. Development of an Airborne High Resolution TV System (AHRTS)

    DTIC Science & Technology

    1975-11-01

    GOVT ACCESSION NO READ INSTRUCTIONS BEFORE COMPLETING FORM JP RECIPIENT’S CATALOG NUMBER DEVELOPMENT OF AN ^IRBORNE HIGH JESOLUTION TV SYSTEM...c. Sytem Elements The essential Airborne Subsystem elements of camera, video tape recorder, transmitter and antennas are required to have...The camera operated over the 3000:1 light change as required. A solar shutter was Incorporated to protect the vidicon from damage from direct view

  5. Automatic Exposure Iris Control (AEIC) for data acquisition camera

    NASA Technical Reports Server (NTRS)

    Mcatee, G. E., Jr.; Stoap, L. J.; Solheim, C. D.; Sharpsteen, J. T.

    1975-01-01

    A lens design capable of operating over a total range of f/1.4 to f/11.0 with through the lens light sensing is presented along with a system which compensates for ASA film speeds as well as shutter openings. The space shuttle camera system package is designed so that it can be assembled on the existing 16 mm DAC with a minimum of alteration to the camera.

  6. Laser Measurement Of Convective-Heat-Transfer Coefficient

    NASA Technical Reports Server (NTRS)

    Porro, A. Robert; Hingst, Warren R.; Chriss, Randall M.; Seablom, Kirk D.; Keith, Theo G., Jr.

    1994-01-01

    Coefficient of convective transfer of heat at spot on surface of wind-tunnel model computed from measurements acquired by developmental laser-induced-heat-flux technique. Enables non-intrusive measurements of convective-heat-transfer coefficients at many points across surfaces of models in complicated, three-dimensional, high-speed flows. Measurement spot scanned across surface of model. Apparatus includes argon-ion laser, attenuator/beam splitter electronic shutter infrared camera, and subsystem.

  7. Digital Semaphore: Technical Feasibility of QR Code Optical Signaling for Fleet Communications

    DTIC Science & Technology

    2013-06-01

    Standards (http://www.iso.org) JIS Japanese Industrial Standard JPEG Joint Photographic Experts Group (digital image format; http://www.jpeg.org) LED...Denso Wave corporation in the 1990s for the Japanese automotive manufacturing industry. See Appendix A for full details. Reed-Solomon Error...eliminates camera blur induced by the shutter, providing clear images at extremely high frame rates. Thusly, digital cinema cameras are more suitable

  8. Afghanistan, Counterinsurgency, and the Indirect Approach

    DTIC Science & Technology

    2010-04-01

    shuttered cinemas , barred people from watching the soccer World Cup, and held public amputations or stonings of violators of their stark religious... Japanese warplanes struck the U.S. Navy at Pearl Harbor, Japan invaded the islands. The Impe- rial Japanese Army defeated the tiny American garrisons at...U.S. forces freed the Philippines from Japanese rule. Nearly 2 years later, the island nation attained its full sovereignty on 4 July 1946. The

  9. The BepiColombo Serena/ELENA instrument: performances and testing

    NASA Astrophysics Data System (ADS)

    Orsini, Stefano; De Angelis, Elisabetta; Selci, Stefano; Di Lellis, Andrea; Leoni, Roberto; Rispoli, Rosanna; Colasanti, Luca; Vertolli, Nello; Mura, Alessandro; Milillo, Anna; D'Alessandro, Marco; Mattioli, Francesco; Maschietti, Daniele; Brienza, Daniele; Scheer, Juergen; Wurz, Peter

    2013-04-01

    The neutral sensor ELENA (Emitted Low-Energy Neutral Atoms) for the ESA cornerstone BepiColombo mission to Mercury (in the SERENA instrument package) is a new kind of low energetic neutral atoms instrument, mostly devoted to sputtering emission from planetary surfaces, from E ~20 eV up to E~5 keV, within 1-D (4.5°x76°). ELENA is a Time of Flight instrument, based on the novel concept of ultra-sonic oscillating shutter as Start section and MCP detector with 32 discrete anodes as a direct Stop section. ELENA will monitor the emission of neutral atoms from the whole surface of Mercury allowing to investigate the interaction between the environment and the planet, the global particle loss-rate and the remote sensing of the surface properties. In particular, surface release processes are investigated by identifying particles release from the surface via solar wind-induced ion sputtering (<1eV - >100 eV) as well as Hydrogen back-scattered at hundreds eV. The results of ELENA performance test, will be presented: the innovative Shutter system (Start section) operating at requested frequencies (around 43kHz), the ion rejection capability of double deflection system, the Stop detector, the electronic boards, the validation test.

  10. Arrays of quasi-hexagonally ordered silica nanopillars with independently controlled areal density, diameter and height gradients

    NASA Astrophysics Data System (ADS)

    Özdemir, Burcin; Huang, Wenting; Plettl, Alfred; Ziemann, Paul

    2015-03-01

    A consecutive fabrication approach of independently tailored gradients of the topographical parameters distance, diameter and height in arrays of well-ordered nanopillars on smooth SiO2-Si-wafers is presented. For this purpose, previously reported preparation techniques are further developed and combined. First, self-assembly of Au-salt loaded micelles by dip-coating with computer-controlled pulling-out velocities and subsequent hydrogen plasma treatment produce quasi-hexagonally ordered, 2-dimensional arrays of Au nanoparticles (NPs) with unidirectional variations of the interparticle distances along the pulling direction between 50-120 nm. Second, the distance (or areal density) gradient profile received in this way is superimposed with a diameter-controlled gradient profile of the NPs applying a selective photochemical growth technique. For demonstration, a 1D shutter is used for locally defined UV exposure times to prepare Au NP size gradients varying between 12 and 30 nm. Third, these double-gradient NP arrangements serve as etching masks in a following reactive ion etching step delivering arrays of nanopillars. For height gradient generation, the etching time is locally controlled by applying a shutter made from Si wafer piece. Due to the high flexibility of the etching process, the preparation route works on various materials such as cover slips, silicon, silicon oxide, silicon nitride and silicon carbide.

  11. Creating Ruddlesden-Popper phases by hybrid molecular beam epitaxy

    NASA Astrophysics Data System (ADS)

    Haislmaier, Ryan C.; Stone, Greg; Alem, Nasim; Engel-Herbert, Roman

    2016-07-01

    The synthesis of a 50 unit cell thick n = 4 Srn+1TinO3n+1 (Sr5Ti4O13) Ruddlesden-Popper (RP) phase film is demonstrated by sequentially depositing SrO and TiO2 layers in an alternating fashion using hybrid molecular beam epitaxy (MBE), where Ti was supplied using titanium tetraisopropoxide (TTIP). A detailed calibration procedure is outlined for determining the shuttering times to deposit SrO and TiO2 layers with precise monolayer doses using in-situ reflection high energy electron diffraction (RHEED) as feedback. Using optimized Sr and TTIP shuttering times, a fully automated growth of the n = 4 RP phase was carried out over a period of >4.5 h. Very stable RHEED intensity oscillations were observed over the entire growth period. The structural characterization by X-ray diffraction and high resolution transmission electron microscopy revealed that a constant periodicity of four SrTiO3 perovskite unit cell blocks separating the double SrO rocksalt layer was maintained throughout the entire film thickness with a very little amount of planar faults oriented perpendicular to the growth front direction. These results illustrate that hybrid MBE is capable of layer-by-layer growth with atomic level precision and excellent flux stability.

  12. Time multiplexing for increased FOV and resolution in virtual reality

    NASA Astrophysics Data System (ADS)

    Miñano, Juan C.; Benitez, Pablo; Grabovičkić, Dejan; Zamora, Pablo; Buljan, Marina; Narasimhan, Bharathwaj

    2017-06-01

    We introduce a time multiplexing strategy to increase the total pixel count of the virtual image seen in a VR headset. This translates into an improvement of the pixel density or the Field of View FOV (or both) A given virtual image is displayed by generating a succession of partial real images, each representing part of the virtual image and together representing the virtual image. Each partial real image uses the full set of physical pixels available in the display. The partial real images are successively formed and combine spatially and temporally to form a virtual image viewable from the eye position. Partial real images are imaged through different optical channels depending of its time slot. Shutters or other schemes are used to avoid that a partial real image be imaged through the wrong optical channels or at the wrong time slot. This time multiplexing strategy needs real images be shown at high frame rates (>120fps). Available display and shutters technologies are discussed. Several optical designs for achieving this time multiplexing scheme in a compact format are shown. This time multiplexing scheme allows increasing the resolution/FOV of the virtual image not only by increasing the physical pixel density but also by decreasing the pixels switching time, a feature that may be simpler to achieve in certain circumstances.

  13. Objective Evaluation of Visual Fatigue Using Binocular Fusion Maintenance.

    PubMed

    Hirota, Masakazu; Morimoto, Takeshi; Kanda, Hiroyuki; Endo, Takao; Miyoshi, Tomomitsu; Miyagawa, Suguru; Hirohara, Yoko; Yamaguchi, Tatsuo; Saika, Makoto; Fujikado, Takashi

    2018-03-01

    In this study, we investigated whether an individual's visual fatigue can be evaluated objectively and quantitatively from their ability to maintain binocular fusion. Binocular fusion maintenance (BFM) was measured using a custom-made binocular open-view Shack-Hartmann wavefront aberrometer equipped with liquid crystal shutters, wherein eye movements and wavefront aberrations were measured simultaneously. Transmittance in the liquid crystal shutter in front of the subject's nondominant eye was reduced linearly, and BFM was determined from the transmittance at the point when binocular fusion was broken and vergence eye movement was induced. In total, 40 healthy subjects underwent the BFM test and completed a questionnaire regarding subjective symptoms before and after a visual task lasting 30 minutes. BFM was significantly reduced after the visual task ( P < 0.001) and was negatively correlated with the total subjective eye symptom score (adjusted R 2 = 0.752, P < 0.001). Furthermore, the diagnostic accuracy for visual fatigue was significantly higher in BFM than in the conventional test results (aggregated fusional vergence range, near point of convergence, and the high-frequency component of accommodative microfluctuations; P = 0.007). These results suggest that BFM can be used as an indicator for evaluating visual fatigue. BFM can be used to evaluate the visual fatigue caused by the new visual devices, such as head-mount display, objectively.

  14. Feasibility of using acoustic method in monitoring the penetration status during the Pulse Mode Laser Welding process

    NASA Astrophysics Data System (ADS)

    Yusof, M. F. M.; Ishak, M.; Ghazali, M. F.

    2017-09-01

    In this paper, the feasibility of using acoustic method to monitor the depth of penetration was investigated by determine the characteristic of the acquired sound throughout the pulse mode laser welding process. To achieve the aim, the sound signal was acquired during the pulsed laser welding process on the 2 mm structural carbon steel plate. During the experiment, the laser peak power and pulse width was set to be varied while welding speed was constantly at 2 mm/s. Result from the experiment revealed that the sound pressure level of the acquired sound was linearly related to the pulse energy as well as the depth of penetration for welding process using 2ms pulse width. However, as the pulse width increase, the sound pressure level show insignificant change with respect to the change in the depth of penetration when the pulse energy reaches certain values. The reported result shows that this was happen due to the occurrence of spatter which suppressed the information associated with the generation of plasma plume as the product of high pulse energy. In this work, it was demonstrated that in some condition, the acoustic method was found to be potentially suitable to be used as a medium to monitor the depth of weld on online basis. To increase the robustness of this method to be used in wider range of parameter, it was believed that some other post processing method is needed in order to extract the specific information associated with the depth of penetration from the acquired sound.

  15. The LILIA experiment: Energy selection and post-acceleration of laser generated protons

    NASA Astrophysics Data System (ADS)

    Turchetti, Giorgio; Sinigardi, Stefano; Londrillo, Pasquale; Rossi, Francesco; Sumini, Marco; Giove, Dario; De Martinis, Carlo

    2012-12-01

    The LILIA experiment is planned at the SPARCLAB facility of the Frascati INFN laboratories. We have simulated the laser acceleration of protons, the transport and energy selection with collimators and a pulsed solenoid and the post-acceleration with a compact high field linac. For the highest achievable intensity corresponding to a = 30 over 108 protons at 30 MeV with a 3% spread are selected, and at least107 protons are post-accelerated up to 60 MeV. If a 10 Hz repetition rated can be achieved the delivered dose would be suitable for the treatment of small superficial tumors.

  16. Wideband Arrhythmia-Insensitive-Rapid (AIR) Pulse Sequence for Cardiac T1 mapping without Image Artifacts induced by ICD

    PubMed Central

    Hong, KyungPyo; Jeong, Eun-Kee; Wall, T. Scott; Drakos, Stavros G.; Kim, Daniel

    2015-01-01

    Purpose To develop and evaluate a wideband arrhythmia-insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by implantable-cardioverter-defibrillator (ICD). Methods We developed a wideband AIR pulse sequence by incorporating a saturation pulse with wide frequency bandwidth (8.9 kHz), in order to achieve uniform T1 weighting in the heart with ICD. We tested the performance of original and “wideband” AIR cardiac T1 mapping pulse sequences in phantom and human experiments at 1.5T. Results In 5 phantoms representing native myocardium and blood and post-contrast blood/tissue T1 values, compared with the control T1 values measured with an inversion-recovery pulse sequence without ICD, T1 values measured with original AIR with ICD were considerably lower (absolute percent error >29%), whereas T1 values measured with wideband AIR with ICD were similar (absolute percent error <5%). Similarly, in 11 human subjects, compared with the control T1 values measured with original AIR without ICD, T1 measured with original AIR with ICD was significantly lower (absolute percent error >10.1%), whereas T1 measured with wideband AIR with ICD was similar (absolute percent error <2.0%). Conclusion This study demonstrates the feasibility of a wideband pulse sequence for cardiac T1 mapping without significant image artifacts induced by ICD. PMID:25975192

  17. Determination of cellular injury and death thresholds following exposure to high voltage 10ns electrical pulses

    NASA Astrophysics Data System (ADS)

    Ibey, Bennett L.; Roth, Caleb C.; Bernhard, Joshua A.; Pakhomov, Andrei G.; Wilmink, Gerald J.; Pakhomova, Olga

    2011-03-01

    Intense, nanosecond-duration electric pulses (nsEP) have been introduced as a novel modality to alter cellular function, with a mechanism of action qualitatively different from micro- and millisecond duration pulses used in electroporation. In this study, we determined the thresholds for plasma membrane injury (within 15 minutes) and cell death (at 24 hours) for 4 different cell types (CHO-K1, HeLa, Jurkat and U937). Plasma membrane injury was measured by flow cytometry using two fluorescent dyes, namely Annexin V-FITC, which binds to phosphatidylserine (PS) upon its externalization (subtle membrane injury), and propidium iodide (PI), which is typically impermeable to the cell, but enters when large pores are formed in the plasma membrane. In all cell types, 10-ns pulses caused phosphatidylserine (PS) externalization at low doses (<150kV/cm and 100 pulses for each cell type) and no PI uptake. Jurkat and U937 cell lines showed substantial cell death without uptake of PI (15 minutes post exposure) suggesting either delayed permeabilization due to swelling, or damage to intracellular components. In CHO-K1 and HeLa cell lines, PI uptake occurred at low doses relative to that necessary to cause cell death suggesting a necrotic death similar to longer pulse exposures. These findings suggest that nanosecond pulses may be beneficial in applications that require selective elimination of specific cell types.

  18. Evaluating the potential for internal injuries from a pulsed 3.8-micron laser

    NASA Astrophysics Data System (ADS)

    Johnson, Thomas E.; Fitzhugh, Dawn C.; McPherson, Nicole; Winston, Golda C. H.; Winston, Tridaugh D.; Randolph, Donald Q.

    2005-04-01

    The goal of this study is to determine if a high energy laser pulse can cause internal injury that cannot be grossly visualized. High power lasers are currently in development such as the Medical Free Electron Laser (MFEL), the Anti-Ballistic Laser (ABL) and the Tactical High Energy Laser (THEL) and the potential exists for human exposure. Little is known about the effects of these high output lasers on internal organs when a thoracic exposure occurs. This study utilized a 3.8 micron single 8 microsecond pulse laser for all exposures. Yucatan miniature pigs were exposed to a single pulse over the sternum. In addition, some animals were also exposed in the axillary region. Creatine phosphokinase (CPK) and troponin levels were measured prior to and post exposure to assess cardiac muscle damage. Gross and histologic changes were determined for the porcine skin, lung tissue, and cardiac muscle. This study explores if a greater than class 4 laser classification is warranted based on the potential for thoracic injury.

  19. Generation of UV light by intense ultrashort laser pulses in air

    NASA Astrophysics Data System (ADS)

    Alexeev, Ilya; Ting, Antonio; Gordon, Daniel; Briscoe, Eldridge; Penano, Joe; Sprangle, Phillip

    2004-11-01

    The propagation of collimated high-peak-power ultrashort laser pulses in air has attracted considerable attention, which may have a variety of important applications including remote sensing and chemical-biological aerosols standoff detection. Sub-millimeter diameter laser filaments can develop without any focusing optics and instead solely from laser self-focusing and plasma formation in air. These filaments can produce ultraviolet radiations in the form of the 3rd harmonic of the fundamental frequency and also through spectral broadening due to self-phase modulation of the laser pulse. Using femtosecond laser pulses produced by a high power Ti:Sapphire laser (0.8 TW, 50 fs, 800 nm) we observed generation of the third harmonic radiation light in air (centered around 267 nm) by the laser filaments. Characterization of the 3rd harmonic generation with respect to the major gas components of the air will be reported. Supported by the ONR and RDECOM. I. Alexeev is NRC/NRL Post-Doc.

  20. Effects of a nitrate-rich meal on arterial stiffness and blood pressure in healthy volunteers.

    PubMed

    Liu, Alex H; Bondonno, Catherine P; Croft, Kevin D; Puddey, Ian B; Woodman, Richard J; Rich, Lisa; Ward, Natalie C; Vita, Joseph A; Hodgson, Jonathan M

    2013-11-30

    An increase in nitrate intake can augment circulating nitrite and nitric oxide. This may lead to lower blood pressure and improved vascular function. Green leafy vegetables, such as spinach, are rich sources of nitrate. We aimed to assess the acute effects of a nitrate-rich meal containing spinach on arterial stiffness and blood pressure in healthy men and women. Twenty-six participants aged 38-69years were recruited to a randomized controlled cross-over trial. The acute effects of two energy-matched (2000kJ) meals, administered in random order, were compared. The meals were either high nitrate (220mg of nitrate derived from spinach [spinach]) or low nitrate [control]. Outcome measurements were performed pre-meal and at specific time points up to 210min post meal. Spinach resulted in an eightfold increase in salivary nitrite and a sevenfold increase in salivary nitrate concentrations from pre-meal (P<0.001) to 120min post meal. Spinach compared with control resulted in higher large artery elasticity index (P<0.001), and lower pulse pressure (P<0.001) and systolic blood pressure (P<0.001). Post meal carotid-femoral pulse wave velocity (P=0.07), augmentation index (P=0.63), small artery elasticity index (P=0.98) and diastolic blood pressure (P=0.13) were not significantly altered by spinach relative to control. Therefore, consumption of a nitrate-rich meal can lower systolic blood pressure and pulse pressure and increase large artery compliance acutely in healthy men and women. If sustained, these effects could contribute to better cardiovascular health. Copyright © 2013 Elsevier Inc. All rights reserved.

Top