Sample records for post-test analysis laboratory

  1. 49 CFR Appendix B to Part 219 - Designation of Laboratory for Post-Accident Toxicological Testing

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Designation of Laboratory for Post-Accident.... 219, App. B Appendix B to Part 219—Designation of Laboratory for Post-Accident Toxicological Testing The following laboratory is currently designated to conduct post-accident toxicological analysis under...

  2. Argonne Collaborative Center for Energy Storage Science (ACCESS)

    Science.gov Websites

    Analysis and Diagnostics Laboratory (EADL) Post- Test Facility Access Proven Capabilities Argonne has Analysis, Modeling and Prototyping (CAMP) Electrochemical Analysis and Diagnostics Laboratory (EADL) Post -Test Facility Argonne User Facilities Industries Transportation Consumer Electronics Defense Electric

  3. A laboratory comparison of individual Targis/Vectris posts with standard fiberglass posts.

    PubMed

    Corsalini, Massimo; Genovese, Katia; Lamberti, Luciano; Pappalettere, Carmine; Carella, Mauro; Carossa, Stefano

    2007-01-01

    This article presents an in vitro analysis of a specific occlusal loading test on endodontically treated teeth restored with 2 different composite post materials. Individual, customized posts (IFPs) were compared to standard fiberglass posts (SFPs). The selected IFPs (standard cylindric Targis/Vectris posts) were compared to SFPs (Conic 6% Post, Ghimas). The posts were first subjected to a 3-point bending test to compare their flexural elastic properties. They were then used to restore 22 endodontically treated artificial maxillary central incisors and subjected to a specific occlusal loading simulation test. The loading test showed that IFP restorations performed better than SFP restorations. A clinical evaluation of this laboratory observation is suggested.

  4. Evaluation of the Impact of Kerojet (trademark) Aquarius Water Scavenger Additive on the Thermal Stability of Jet A Fuels

    DTIC Science & Technology

    2014-12-01

    113 Figure 64 - Elemental Analysis, Typical TMS Post - Test , Post Carbon Burn-off, Hexane rinsed ............ 114 Figure 65 – SEM (20X...Agency’s Wright-Patterson Aerospace Fuels Laboratory AFRL Air Force Research Laboratory AFTSTU Aviation Fuel Thermal Stability Test Unit ARSFSS Advanced...Approved for public release; distribution unlimited. For all ARSFSS testing , SV hysteresis is measure pre- and post - test and is defined by relating

  5. Battery testing at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    1993-03-01

    Argonne National Laboratory's Analysis & Diagnostic Laboratory (ADL) tests advanced batteries under simulated electric and hybrid vehicle operating conditions. The ADL facilities also include a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The battery evaluations and post-test examinations help identify factors that limit system performance and life and the most-promising R&D approaches for overcoming these limitations. Since 1991, performance characterizations and/or life evaluations have been conducted on eight battery technologies: Na/S, Li/S, Zn/Br, Ni/MH, Ni/Zn, Ni/Cd, Ni/Fe, and lead-acid. These evaluations were performed for the Department of Energy's. Office of Transportation Technologies, Electric and Hybrid Propulsion Division (DOE/OTT/EHP), and Electric Power Research Institute (EPRI) Transportation Program. The results obtained are discussed.

  6. Semen Analysis Test

    MedlinePlus

    ... present in the semen sample. What does the test result mean? Post-vasectomy sperm check: Couples may discontinue using other ... Pp 400-415, 2017. (©2017) Mayo Medical Laboratories. Post Vasectomy Check, Semen. Available online at ... Accessed February 2017. ...

  7. The Effect of Degrees of Direction in the Qualitative Analysis Laboratory on Retention of Learning

    ERIC Educational Resources Information Center

    Holcomb, Charlie M.

    1971-01-01

    Students given sufficient information to be able to design chemical separations of cations performed better on a post-test, and on a four-month retention test on chemical knowledge and laboratory procedures, than students given a detailed laboratory guide listing the steps to follow. (AL)

  8. External quality assessment of medical laboratories in Croatia: preliminary evaluation of post-analytical laboratory testing.

    PubMed

    Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana

    2017-02-15

    Proper standardization of laboratory testing requires assessment of performance after the tests are performed, known as the post-analytical phase. A nationwide external quality assessment (EQA) scheme implemented in Croatia in 2014 includes a questionnaire on post-analytical practices, and the present study examined laboratory responses in order to identify current post-analytical phase practices and identify areas for improvement. In four EQA exercises between September 2014 and December 2015, 145-174 medical laboratories across Croatia were surveyed using the Module 11 questionnaire on the post-analytical phase of testing. Based on their responses, the laboratories were evaluated on four quality indicators: turnaround time (TAT), critical values, interpretative comments and procedures in the event of abnormal results. Results were presented as absolute numbers and percentages. Just over half of laboratories (56.3%) monitored TAT. Laboratories varied substantially in how they dealt with critical values. Most laboratories (65-97%) issued interpretative comments with test results. One third of medical laboratories (30.6-33.3%) issued abnormal test results without confirming them in additional testing. Our results suggest that the nationwide post-analytical EQA scheme launched in 2014 in Croatia has yet to be implemented to the full. To close the gaps between existing recommendations and laboratory practice, laboratory professionals should focus on ensuring that TAT is monitored and lists of critical values are established within laboratories. Professional bodies/institutions should focus on clarify and harmonized rules to standardized practices and applied for adding interpretative comments to laboratory test results and for dealing with abnormal test results.

  9. A multivariate assessment of the effect of the laboratory homework component of a microcomputer-based laboratory for a college freshman physics course

    NASA Astrophysics Data System (ADS)

    Ramlo, Susan E.

    Microcomputer-based laboratories (MBLs) have been defined as software that uses an electronic probe to collect information about a physical system and then converts that information into graphical systems in real-time. Realtime Physics Laboratories (RTP) are an example of laboratories that combine the use of MBLs with collaboration and guided-inquiry. RTP Mechanics Laboratories include both laboratory activities and laboratory homework for the first semester of college freshman physics courses. Prior research has investigated the effectiveness of the RTP laboratories as a package (laboratory activities with laboratory homework). In this study, an experimental-treatment had students complete both the RTP laboratory activity and the associated laboratory homework during the same laboratory period. Observations of this treatment indicated that students primarily consulted the laboratory instructor and referred to their completed laboratory activity while completing the homework in their collaborative groups. In the control-treatment, students completed the laboratory homework outside the laboratory period. Measures of force and motion conceptual understanding included the Force and Motion Conceptual Understanding (FMCE), a 47 multiple-choice question test. Analyses of the FMCE indicated that it is both a reliable and a valid measure of force and motion conceptual understanding. A distinct, five-factor structure for the FMCE post-test answers reflected specific concepts related to force and motion. However, the three FMCE pretest factors were less distinct. Analysis of the experimental-treatment, compared to a control-treatment, included multiple regression analysis with covariates of age, prior physics-classroom experience, and the three FMCE pretest factors. Criterion variables included each of the five post-test factors, the total laboratory homework score, and a group of seven exam questions. The results were all positive, in favor of the experimental-treatment. However, the results were significant only with the criterions of the FMCE post-test factor "Concepts Regarding Newton's First and Second Laws" and the laboratory homework score. The interaction between the treatments and prior physics-classroom experience was not significant. Implications of the qualitative and quantitative findings are discussed.

  10. CSF Analysis

    MedlinePlus

    ... one or more hours to avoid a potential post-test headache. The lumbar puncture procedure usually takes less ... in CSF with laboratory tests such as molecular tests or culture. Parasitic meningitis or encephalitis are rare and can be lethal. One example is an infection caused by the free-living ...

  11. Assuring the Quality of Test Results in the Field of Nuclear Techniques and Ionizing Radiation. The Practical Implementation of Section 5.9 of the EN ISO/IEC 17025 Standard

    NASA Astrophysics Data System (ADS)

    Cucu, Daniela; Woods, Mike

    2008-08-01

    The paper aims to present a practical approach for testing laboratories to ensure the quality of their test results. It is based on the experience gained in assessing a large number of testing laboratories, discussing with management and staff, reviewing results obtained in national and international PTs and ILCs and exchanging information in the EA laboratory committee. According to EN ISO/IEC 17025, an accredited laboratory has to implement a programme to ensure the quality of its test results for each measurand. Pre-analytical, analytical and post-analytical measures shall be applied in a systematic manner. They shall include both quality control and quality assurance measures. When designing the quality assurance programme a laboratory should consider pre-analytical activities (like personnel training, selection and validation of test methods, qualifying equipment), analytical activities ranging from sampling, sample preparation, instrumental analysis and post-analytical activities (like decoding, calculation, use of statistical tests or packages, management of results). Designed on different levels (analyst, quality manager and technical manager), including a variety of measures, the programme shall ensure the validity and accuracy of test results, the adequacy of the management system, prove the laboratory's competence in performing tests under accreditation and last but not least show the comparability of test results. Laboratory management should establish performance targets and review periodically QC/QA results against them, implementing appropriate measures in case of non-compliance.

  12. Designing experiments on thermal interactions by secondary-school students in a simulated laboratory environment

    NASA Astrophysics Data System (ADS)

    Lefkos, Ioannis; Psillos, Dimitris; Hatzikraniotis, Euripides

    2011-07-01

    Background and purpose: The aim of this study was to explore the effect of investigative activities with manipulations in a virtual laboratory on students' ability to design experiments. Sample Fourteen students in a lower secondary school in Greece attended a teaching sequence on thermal phenomena based on the use of information and communication technology, and specifically of the simulated virtual laboratory 'ThermoLab'. Design and methods A pre-post comparison was applied. Students' design of experiments was rated in eight dimensions; namely, hypothesis forming and verification, selection of variables, initial conditions, device settings, materials and devices used, process and phenomena description. A three-level ranking scheme was employed for the evaluation of students' answers in each dimension. Results A Wilcoxon signed-rank test revealed a statistically significant difference between the students' pre- and post-test scores. Additional analysis by comparing the pre- and post-test scores using the Hake gain showed high gains in all but one dimension, which suggests that this improvement was almost inclusive. Conclusions We consider that our findings support the statement that there was an improvement in students' ability to design experiments.

  13. 76 FR 47917 - Lead; Clearance and Clearance Testing Requirements for the Renovation, Repair, and Painting Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-05

    ... settlement of litigation over certain post- renovation cleaning requirements of the 2008 Lead Renovation... work practice standards for persons performing renovations for compensation in most pre-1978 housing... it to a recognized laboratory for analysis in lieu of using a lead test kit, minor changes to the...

  14. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus.

    PubMed

    Sacks, David B; Arnold, Mark; Bakris, George L; Bruns, David E; Horvath, Andrea Rita; Kirkman, M Sue; Lernmark, Ake; Metzger, Boyd E; Nathan, David M

    2011-06-01

    Multiple laboratory tests are used to diagnose and manage patients with diabetes mellitus. The quality of the scientific evidence supporting the use of these tests varies substantially. An expert committee compiled evidence-based recommendations for the use of laboratory testing for patients with diabetes. A new system was developed to grade the overall quality of the evidence and the strength of the recommendations. Draft guidelines were posted on the Internet and presented at the 2007 Arnold O. Beckman Conference. The document was modified in response to oral and written comments, and a revised draft was posted in 2010 and again modified in response to written comments. The National Academy of Clinical Biochemistry and the Evidence-Based Laboratory Medicine Committee of the American Association for Clinical Chemistry jointly reviewed the guidelines, which were accepted after revisions by the Professional Practice Committee and subsequently approved by the Executive Committee of the American Diabetes Association. In addition to long-standing criteria based on measurement of plasma glucose, diabetes can be diagnosed by demonstrating increased blood hemoglobin A(1c) (HbA(1c)) concentrations. Monitoring of glycemic control is performed by self-monitoring of plasma or blood glucose with meters and by laboratory analysis of HbA(1c). The potential roles of noninvasive glucose monitoring, genetic testing, and measurement of autoantibodies, urine albumin, insulin, proinsulin, C-peptide, and other analytes are addressed. The guidelines provide specific recommendations that are based on published data or derived from expert consensus. Several analytes have minimal clinical value at present, and their measurement is not recommended.

  15. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus.

    PubMed

    Sacks, David B; Arnold, Mark; Bakris, George L; Bruns, David E; Horvath, Andrea Rita; Kirkman, M Sue; Lernmark, Ake; Metzger, Boyd E; Nathan, David M

    2011-06-01

    Multiple laboratory tests are used to diagnose and manage patients with diabetes mellitus. The quality of the scientific evidence supporting the use of these tests varies substantially. An expert committee compiled evidence-based recommendations for the use of laboratory testing for patients with diabetes. A new system was developed to grade the overall quality of the evidence and the strength of the recommendations. Draft guidelines were posted on the Internet and presented at the 2007 Arnold O. Beckman Conference. The document was modified in response to oral and written comments, and a revised draft was posted in 2010 and again modified in response to written comments. The National Academy of Clinical Biochemistry and the Evidence Based Laboratory Medicine Committee of the AACC jointly reviewed the guidelines, which were accepted after revisions by the Professional Practice Committee and subsequently approved by the Executive Committee of the American Diabetes Association. In addition to long-standing criteria based on measurement of plasma glucose, diabetes can be diagnosed by demonstrating increased blood hemoglobin A(1c) (Hb A(1c)) concentrations. Monitoring of glycemic control is performed by self-monitoring of plasma or blood glucose with meters and by laboratory analysis of Hb A(1c). The potential roles of noninvasive glucose monitoring, genetic testing, and measurement of autoantibodies, urine albumin, insulin, proinsulin, C-peptide, and other analytes are addressed. The guidelines provide specific recommendations that are based on published data or derived from expert consensus. Several analytes have minimal clinical value at present, and their measurement is not recommended.

  16. Operation TEAPOT. Report of the Test Manager Joint Test Organization

    DTIC Science & Technology

    1981-11-01

    Analysis of air, water, and milk samples were made at the laboratory at Mercury. z. 6.4 MONITORING PROCEDURES A mobile surface monitoring group consisting o...additional weather observations proved very use- ful in weather analysis and forecasting as well as for monitoring winds aloft prior to shot time. The...data were also valuable in post analysis for accurate plotting of fallout and determining cloud trajectories. The loca- tion and type of operations of

  17. The effect of aromatherapy on haemodialysis patients' pruritus.

    PubMed

    Cürcani, Mehtap; Tan, Mehtap

    2014-12-01

    To determine the effect of aromatherapy on pruritus observed in haemodialysis patients. Although the prevalence of pruritus in kidney failure has decreased in the recent years, pruritus is a difficult and serious problem which concerns the majority of haemodialysis patents and is hard to cure. A prospective, pretest-post-test quasi-experimental design was used. The research is quasi-experimental clinical trial conducted as pretest and post-test with control groups between January 2011-April 2012, in haemodialysis units of hospitals in Erzurum. The collection of the data is achieved using a questionnaire to detect the patients' individual and pruritus score scale and to clarify certain laboratory parameters regarding the pruritus. Chi-square analysis and t-test are used for the analysis of data. The experimental group's mean post-test pruritus scores (7·20 ± 3·14) were found to be lower than that of control group patients (10·00 ± 2·47), and a highly significant difference was found between the groups (p < 0·001). In the between-groups comparisons of experimental and control group's laboratory parameters, the experimental group's post-test blood urea nitrogen levels (118·26 ± 36·76) were found to be lower than that of control group patients (138·80 ± 48·69), and the between-groups difference was found to be statistically significant (p < 0·05). The results demonstrate that aromatherapy was found to decrease the pruritus problem of haemodialyses patients and led to positive changes in some laboratory parameters related to pruritus. One of the roles of health professionals is to advise individuals, who are living on this problem, using the nonpharmacological methods in checking the itching. By preventing or reducing uraemic pruritus, aromatherapy may also improve quality of life in this patient group. © 2014 John Wiley & Sons Ltd.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luk, V.K.; Hessheimer, M.F.; Matsumoto, T.

    A high pressure test of a mixed-scaled model (1:10 in geometry and 1:4 in shell thickness) of a steel containment vessel (SCV), representing an improved boiling water reactor (BWR) Mark II containment, was conducted on December 11--12, 1996 at Sandia National Laboratories. This paper describes the preliminary results of the high pressure test. In addition, the preliminary post-test measurement data and the preliminary comparison of test data with pretest analysis predictions are also presented.

  19. Comparative Analysis of THOR-NT ATD vs. Hybrid III ATD in Laboratory Vertical Shock Testing

    DTIC Science & Technology

    2013-09-01

    were taken both pretest and post - test for each test event (figure 5). Figure 5. Rigid fixture placed on the drop table with ATD seated: Hybrid III...6 3. Experimental Procedure 6 3.1 Test Setup...frames per second and with a Vision Research Phantom V9.1 (Wayne, NJ) high-speed video camera, sampling 1000 frames per second. 3. Experimental

  20. Errors in clinical laboratories or errors in laboratory medicine?

    PubMed

    Plebani, Mario

    2006-01-01

    Laboratory testing is a highly complex process and, although laboratory services are relatively safe, they are not as safe as they could or should be. Clinical laboratories have long focused their attention on quality control methods and quality assessment programs dealing with analytical aspects of testing. However, a growing body of evidence accumulated in recent decades demonstrates that quality in clinical laboratories cannot be assured by merely focusing on purely analytical aspects. The more recent surveys on errors in laboratory medicine conclude that in the delivery of laboratory testing, mistakes occur more frequently before (pre-analytical) and after (post-analytical) the test has been performed. Most errors are due to pre-analytical factors (46-68.2% of total errors), while a high error rate (18.5-47% of total errors) has also been found in the post-analytical phase. Errors due to analytical problems have been significantly reduced over time, but there is evidence that, particularly for immunoassays, interference may have a serious impact on patients. A description of the most frequent and risky pre-, intra- and post-analytical errors and advice on practical steps for measuring and reducing the risk of errors is therefore given in the present paper. Many mistakes in the Total Testing Process are called "laboratory errors", although these may be due to poor communication, action taken by others involved in the testing process (e.g., physicians, nurses and phlebotomists), or poorly designed processes, all of which are beyond the laboratory's control. Likewise, there is evidence that laboratory information is only partially utilized. A recent document from the International Organization for Standardization (ISO) recommends a new, broader definition of the term "laboratory error" and a classification of errors according to different criteria. In a modern approach to total quality, centered on patients' needs and satisfaction, the risk of errors and mistakes in pre- and post-examination steps must be minimized to guarantee the total quality of laboratory services.

  1. The effect of boric acid on bacterial culture of canine and feline urine.

    PubMed

    Rowlands, M; Blackwood, L; Mas, A; Cripps, P; Crompton, C; Burrow, R

    2011-10-01

    To identify the optimal method of submission of canine and feline urine for bacterial culture. Cystocentesis samples from 250 animals (200 dogs, 50 cats) suspected of having urinary tract infections were collected. The reference aliquot, without preservative, was processed on site within 2 hours. Two further aliquots (one without preservative, one with boric acid) were stored at room temperature for up to 7 hours and then posted by guaranteed next day delivery to a commercial laboratory for analysis. Forty-seven of the samples were positive on culture in the reference test. There was no significant difference between reference test results and those of samples posted without preservative (P=0·39), but samples posted in boric acid were significantly less likely to give a positive result (P=0·01). Samples posted without preservative had a sensitivity of 82% and a specificity of 98%; for boric acid, sensitivity was 73% and specificity 99%. Postal urine samples should be submitted to the laboratory in a plain sterile tube. © 2011 British Small Animal Veterinary Association.

  2. Battery testing at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    Advanced battery technology evaluations are performed under simulated electric-vehicle operating conditions at the Analysis & Diagnostic Laboratory (ADL) of Argonne National Laboratory. The ADL results provide insight into those factors that limit battery performance and life. The ADL facilities include a test laboratory to conduct battery experimental evaluations under simulated application conditions and a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. This paper summarizes the performance characterizations and life evaluations conducted during FY-92 on both single cells and multi-cell modules that encompass six battery technologies (Na/S, Li/FeS, Ni/Metal-Hydride, Ni/Zn, Ni/Cd, Ni/Fe). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division, and the Electric Power Research Institute. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The results help identify the most promising R&D approaches for overcoming battery limitations, and provide battery users, developers, and program managers with a measure of the progress being made in battery R&D programs, a comparison of battery technologies, and basic data for modeling.

  3. Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus

    PubMed Central

    Arnold, Mark; Bakris, George L.; Bruns, David E.; Horvath, Andrea Rita; Kirkman, M. Sue; Lernmark, Ake; Metzger, Boyd E.; Nathan, David M.

    2011-01-01

    BACKGROUND Multiple laboratory tests are used to diagnose and manage patients with diabetes mellitus. The quality of the scientific evidence supporting the use of these tests varies substantially. APPROACH An expert committee compiled evidence-based recommendations for the use of laboratory testing for patients with diabetes. A new system was developed to grade the overall quality of the evidence and the strength of the recommendations. Draft guidelines were posted on the Internet and presented at the 2007 Arnold O. Beckman Conference. The document was modified in response to oral and written comments, and a revised draft was posted in 2010 and again modified in response to written comments. The National Academy of Clinical Biochemistry and the Evidence-Based Laboratory Medicine Committee of the American Association for Clinical Chemistry jointly reviewed the guidelines, which were accepted after revisions by the Professional Practice Committee and subsequently approved by the Executive Committee of the American Diabetes Association. CONTENT In addition to long-standing criteria based on measurement of plasma glucose, diabetes can be diagnosed by demonstrating increased blood hemoglobin A1c (HbA1c) concentrations. Monitoring of glycemic control is performed by self-monitoring of plasma or blood glucose with meters and by laboratory analysis of HbA1c. The potential roles of noninvasive glucose monitoring, genetic testing, and measurement of autoantibodies, urine albumin, insulin, proinsulin, C-peptide, and other analytes are addressed. SUMMARY The guidelines provide specific recommendations that are based on published data or derived from expert consensus. Several analytes have minimal clinical value at present, and their measurement is not recommended. PMID:21617108

  4. Interactive laboratory classes enhance neurophysiological knowledge in Thai medical students.

    PubMed

    Wongjarupong, Nicha; Niyomnaitham, Danai; Vilaisaktipakorn, Pitchamol; Suksiriworaboot, Tanawin; Qureshi, Shaun Peter; Bongsebandhu-Phubhakdi, Saknan

    2018-03-01

    Interactive laboratory class (ILC) is a two-way communication teaching method that encourages students to correlate laboratory findings with materials from lectures. In Thai medical education, active learning methods are uncommon. This paper aims to establish 1) if ILCs would effectively promote physiology learning; 2) if effectiveness would be found in both previously academically high-performing and low-performing students; and 3) the acceptability of ILCs to Thai medical students as a novel learning method. Two hundred seventy-eight second-year medical students were recruited to this study. We conducted three ILC sessions, which followed corresponding lectures. We carried out multiple-choice pre- and post-ILC assessments of knowledge and compared by repeated-measures ANOVA and unpaired t-test. Subgroup analysis was performed to compare high-performance (HighP) and low-performance (LowP) students. After the ILCs, participants self-rated their knowledge and satisfaction. Post-ILC test scores increased significantly compared with pre-ILC test scores in all three sessions. Mean scores of each post-ILC test increased significantly from pre-ILC test in both LowP and HighP groups. More students self-reported a "very high" and "high" level of knowledge after ILCs. Most students agreed that ILCs provided more discussion opportunity, motivated their learning, and made lessons more enjoyable. As an adjunct to lectures, ILCs can enhance knowledge in medical students, regardless of previous academic performance. Students perceived ILC as useful and acceptable. This study supports the active learning methods in physiology education, regardless of cultural context.

  5. Implementation of Scientific Community Laboratories and Their Effect on Student Conceptual Learning, Attitudes, and Understanding of Uncertainty

    NASA Astrophysics Data System (ADS)

    Lark, Adam

    Scientific Community Laboratories, developed by The University of Maryland, have shown initial promise as laboratories meant to emulate the practice of doing physics. These laboratories have been re-created by incorporating their design elements with the University of Toledo course structure and resources. The laboratories have been titled the Scientific Learning Community (SLC) Laboratories. A comparative study between these SLC laboratories and the University of Toledo physics department's traditional laboratories was executed during the fall 2012 semester on first semester calculus-based physics students. Three tests were executed as pre-test and post-tests to capture the change in students' concept knowledge, attitudes, and understanding of uncertainty. The Force Concept Inventory (FCI) was used to evaluate students' conceptual changes through the semester and average normalized gains were compared between both traditional and SLC laboratories. The Colorado Learning Attitudes about Science Survey for Experimental Physics (E-CLASS) was conducted to elucidate students' change in attitudes through the course of each laboratory. Finally, interviews regarding data analysis and uncertainty were transcribed and coded to track changes in the way students understand uncertainty and data analysis in experimental physics after their participation in both laboratory type. Students in the SLC laboratories showed a notable an increase conceptual knowledge and attitudes when compared to traditional laboratories. SLC students' understanding of uncertainty showed most improvement, diverging completely from students in the traditional laboratories, who declined throughout the semester.

  6. A critical investigation of post-liquefaction strength and steady-state flow behavior of saturated soils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jong, H.L.

    1988-01-01

    The first objective was to perform a critical evaluation of the recently proposed steady-state analysis methodology for evaluation of post-liquefaction stability of potentially liquefiable soils. This analysis procedure is based on direct comparison between the in-situ undrained residual (steady state) strength of soils in an embankment or foundation, and the driving shear stresses in these soils. A laboratory investigation was performed to investigate factors affecting steady-state strengths, and also to evaluate the validity of assumptions involved in correcting the results of laboratory steady-state strength tests on undisturbed samples for effects of sampling disturbance in order to estimate in-situ strengths. Next,more » a field case study was performed using the steady-state analysis and testing methodologies to analyze Lower San Fernando Dam, which suffered a liquefaction-induced slope failure as a results of a 1971 earthquake. This leads to the second objective which was to extend the Lower San Fernando Dam case study to consideration of analysis methods used to evaluate the likelihood of triggering liquefaction during an earthquake. Finally, a number of the high quality undisturbed samples were subjected to undrained cyclic testing in order to repeat an earlier (1973) study of the use of cyclic tests data to predict liquefaction behavior at Lower San Fernando Dam.« less

  7. Documentation of operational protocol for the use of MAMA software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwartz, Daniel S.

    2016-01-21

    Image analysis of Scanning Electron Microscope (SEM) micrographs is a complex process that can vary significantly between analysts. The factors causing the variation are numerous, and the purpose of Task 2b is to develop and test a set of protocols designed to minimize variation in image analysis between different analysts and laboratories, specifically using the MAMA software package, Version 2.1. The protocols were designed to be “minimally invasive”, so that expert SEM operators will not be overly constrained in the way they analyze particle samples. The protocols will be tested using a round-robin approach where results from expert SEM usersmore » at Los Alamos National Laboratory, Lawrence Livermore National Laboratory, Pacific Northwest National Laboratory, Savannah River National Laboratory, and the National Institute of Standards and Testing will be compared. The variation of the results will be used to quantify uncertainty in the particle image analysis process. The round-robin exercise will proceed with 3 levels of rigor, each with their own set of protocols, as described below in Tasks 2b.1, 2b.2, and 2b.3. The uncertainty will be developed using NIST standard reference material SRM 1984 “Thermal Spray Powder – Particle Size Distribution, Tungsten Carbide/Cobalt (Acicular)” [Reference 1]. Full details are available in the Certificate of Analysis, posted on the NIST website (http://www.nist.gov/srm/).« less

  8. Midodrine as a Countermeasure to Orthostatic Hypotension Immediately After Space Shuttle Landing

    NASA Technical Reports Server (NTRS)

    Platts, Steven H.; Stenger, Michael B.; Ribeiro, L. Christine; Lee, Stuart M. C.

    2010-01-01

    Midodrine prevents post-space flight orthostatic intolerance when testing is conducted in a controlled laboratory setting within 2-4 hours after Space Shuttle landing. It is unknown if midodrine is as effective during re-entry and immediately following landing. METHODS: Cardiovascular responses to 10 minutes of 80 head-up tilt in five male astronauts were compared before and immediately after Space Shuttle missions. Preflight tests were conducted in the Johnson Space Center Cardiovascular Laboratory without midodrine. Post-flight testing was performed in the Crew Transport Vehicle on the Space Shuttle runway within 60 minutes of landing; midodrine was self-administered before re-entry. Survival analysis was performed (Gehan-Breslow test) to compare presyncope rates pre- to post-flight. Cardiovascular responses (last minute standing minus supine) to tilt before and after space flight were compared using paired t-tests. RESULTS: Midodrine did not prevent post-flight orthostatic hypotension in two of the five astronauts, but the rate of presyncope across the group did not increase (p=0.17) from pre- to post-flight. Also, although the change in heart rate from supine to the last minute of standing was not affected by space flight, systolic blood pressure decreased more (p=0.05) and diastolic blood pressure tended to decrease (p=0.08) after space flight. CONCLUSIONS: Accurate interpretation of the current results requires that similar data be collected in control subjects (without midodrine) on the CTV. However, drug interaction concerns with commonly used anti-emetics and potentiation of prolonged QTc intervals observed in long duration astronauts make the routine use of midodrine for immediate post-flight orthostatic hypotension unlikely. 2

  9. Advanced Prototype Fan Operating Experience, Post Test Evaluation, and Refurbishment for PLSS 2.0 Test Use

    NASA Technical Reports Server (NTRS)

    Hodgson, Edward; Oehler, William; Dionne, Steve; Converse, David; Jennings, Mallory A.

    2012-01-01

    NASA s plans for Extravehicular Activity (EVA) portable life support systems for future exploration missions result in different design requirements than those which led to the combined fan / pump / separator in the current ISS Extravehicular Mobility Unit (EMU). To meet these new requirements, NASA contracted with Hamilton Sundstrand to provide two new prototype fans designed to meet anticipated future system requirements. Based on design trade studies, a high speed fan with mechanical bearing support of the rotating elements and a novel non-metallic barrier canned motor design was developed and implemented in the deliverable prototypes. The prototypes, which used two different bearing lubricants, have been extensively tested in both stand-alone and integrated system tests in NASA laboratories and proven to meet the anticipated performance requirements. Subsequently, they have been subjected to post test inspection and analysis in Hamilton Sundstrand laboratories to assess the effects of integrated operation and resultant exposure to vent loop contaminants. Results have confirmed expectations that one of the lubricants would be superior in this application and the prototype fans have been reassembled with new bearings with the superior lubricant. They have now been returned to the Johnson Space Center for further testing and maturation as part of NASA s PLSS 2.0 integrated test effort. This paper will discuss the test history of these units, resulting test data, the results of post test evaluation, and plans for further testing in the near future.

  10. Integrating Point-of-Care Testing into a Community Emergency Department: A Mixed-Methods Evaluation.

    PubMed

    Pines, Jesse M; Zocchi, Mark S; Carter, Caitlin; Marriott, Charles Z; Bernard, Matthew; Warner, Leah H

    2018-05-13

    Point-of-care testing (POCT) is a commonly used technology that hastens the time to laboratory results in emergency departments (ED). We evaluated an ED-based POCT program on ED length of stay and time to care, coupled with qualitative interviews of local ED stakeholders. We conducted a mixed-methods study (2012-16) to examine the impact of point-of-care testing in a single, community ED. The quantiative analysis involved an observational before-after study comparing time to laboratory test result (POC troponin or POC chemistry) and ED length of stay after implementation of POCT, using a propensity-weighted interrupted time series analysis (ITSA). A complementary qualitative analysis involved five semi-structured interviews with staff using grounded theory on the benefits and challenges to ED POCT. A total of 47,399 ED visits were included in the study (24,705 in pre-intervention period and 22,694 in post-intervention). After POCT implementation, overall laboratory testing increased marginally from 61 to 62%. Central laboratory troponin and chemistry declined by >50% and was replaced by POCT. Prior to POCT implementation, time to troponin and chemistry had declined steadily due to other improvements in laboratory efficiency. After POCT implementation, there was an immediate 20 minute further decline (p<0.001) in both time to troponin and time to chemistry results using the propensity-weighted comparisons. However, the declining trend observed prior to POCT implementation did not continue at the same rate post implementation. Similarly, prior to POCT implementation, ED length of stay (LOS) declined due to other quality improvements. After POCT implementation, LOS continued declined at a similar rate. Because of this prior trend, the ITSA did not show a significant decline in LOS attributable to POCT. Common benefits of POCT perceived by staff in qualitative interviews included improved quality of care (64%), and reductions in time to test results (44%). Common challenges included concerns over POCT accuracy (32%), and technical barriers (29%). In the study ED, implementation of POCT was associated with a reduction in time to test result for both troponin and chemistry. Local staff felt that faster time to test result improved quality of care; however, concerns were raised with POCT accuracy. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  11. Post-test analysis of lithium-ion battery materials at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Bareno, Javier; Dietz-Rago, Nancy; Bloom, Ira

    2014-03-01

    Electrochemical performance is often limited by surface and interfacial reactions at the electrodes. However, routine handling of samples can alter the very surfaces that are the object of study. Our approach combines standardized testing of batteries with sample harvesting under inert atmosphere conditions. Cells of different formats are disassembled inside an Argon glove box with controlled water and oxygen concentrations below 2 ppm. Cell components are characterized in situ, guaranteeing that observed changes in physicochemical state are due to electrochemical operation, rather than sample manipulation. We employ a complementary set of spectroscopic, microscopic, electrochemical and metallographic characterization to obtain a complete picture of cell degradation mechanisms. The resulting information about observed degradation mechanisms is provided to materials developers, both academic and industrial, to suggest new strategies and speed up the Research & Development cycle of Li-ion and related technologies. This talk will describe Argonne's post-test analysis laboratory, with an emphasis on capabilities and opportunities for collaboration. Cell disassembly, sample harvesting procedures and recent results will be discussed. This work was performed under the auspices of the U.S. Department of Energy, Office of Vehicle Technologies, Hybrid and Electric Systems, under Contract No. DE-AC02-06CH11357.

  12. Acoustic emission characterization of microcracking in laboratory-scale hydraulic fracturing tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hampton, Jesse; Gutierrez, Marte; Matzar, Luis

    Understanding microcracking near coalesced fracture generation is critically important for hydrocarbon and geothermal reservoir characterization as well as damage evaluation in civil engineering structures. Dense and sometimes random microcracking near coalesced fracture formation alters the mechanical properties of the nearby virgin material. Individual microcrack characterization is also significant in quantifying the material changes near the fracture faces (i.e. damage). Acoustic emission (AE) monitoring and analysis provide unique information regarding the microcracking process temporally, and information concerning the source characterization of individual microcracks can be extracted. In this context, laboratory hydraulic fracture tests were carried out while monitoring the AEs frommore » several piezoelectric transducers. In-depth post-processing of the AE event data was performed for the purpose of understanding the individual source mechanisms. Several source characterization techniques including moment tensor inversion, event parametric analysis, and volumetric deformation analysis were adopted. Post-test fracture characterization through coring, slicing and micro-computed tomographic imaging was performed to determine the coalesced fracture location and structure. Distinct differences in fracture characteristics were found spatially in relation to the openhole injection interval. Individual microcrack AE analysis showed substantial energy reduction emanating spatially from the injection interval. Lastly, it was quantitatively observed that the recorded AE signals provided sufficient information to generalize the damage radiating spatially away from the injection wellbore.« less

  13. Acoustic emission characterization of microcracking in laboratory-scale hydraulic fracturing tests

    DOE PAGES

    Hampton, Jesse; Gutierrez, Marte; Matzar, Luis; ...

    2018-06-11

    Understanding microcracking near coalesced fracture generation is critically important for hydrocarbon and geothermal reservoir characterization as well as damage evaluation in civil engineering structures. Dense and sometimes random microcracking near coalesced fracture formation alters the mechanical properties of the nearby virgin material. Individual microcrack characterization is also significant in quantifying the material changes near the fracture faces (i.e. damage). Acoustic emission (AE) monitoring and analysis provide unique information regarding the microcracking process temporally, and information concerning the source characterization of individual microcracks can be extracted. In this context, laboratory hydraulic fracture tests were carried out while monitoring the AEs frommore » several piezoelectric transducers. In-depth post-processing of the AE event data was performed for the purpose of understanding the individual source mechanisms. Several source characterization techniques including moment tensor inversion, event parametric analysis, and volumetric deformation analysis were adopted. Post-test fracture characterization through coring, slicing and micro-computed tomographic imaging was performed to determine the coalesced fracture location and structure. Distinct differences in fracture characteristics were found spatially in relation to the openhole injection interval. Individual microcrack AE analysis showed substantial energy reduction emanating spatially from the injection interval. Lastly, it was quantitatively observed that the recorded AE signals provided sufficient information to generalize the damage radiating spatially away from the injection wellbore.« less

  14. How Reliable Is Laboratory Testing?

    MedlinePlus

    ... laboratory testing. (See Who's Who in the Lab .) Post-Analytic Activities After the test is completed, the result must be delivered in ... View Sources NOTE: This article is based on research that ... of the Lab Tests Online Editorial Review Board . This article is periodically ...

  15. Promoting clinical and laboratory interaction by harmonization.

    PubMed

    Plebani, Mario; Panteghini, Mauro

    2014-05-15

    The lack of interchangeable results in current practice among clinical laboratories has underpinned greater attention to standardization and harmonization projects. Although the focus was mainly on the standardization and harmonization of measurement procedures and their results, the scope of harmonization goes beyond method and analytical results: it includes all other aspects of laboratory testing, including terminology and units, report formats, reference limits and decision thresholds, as well as test profiles and criteria for the interpretation of results. In particular, as evidence collected in last decades demonstrates that pre-pre- and post-post-analytical steps are more vulnerable to errors, harmonization initiatives should be performed to improve procedures and processes at the laboratory-clinical interface. Managing upstream demand, down-stream interpretation of laboratory results, and subsequent appropriate action through close relationships between laboratorians and clinicians remains a crucial issue of the laboratory testing process. Therefore, initiatives to improve test demand management from one hand and to harmonize procedures to improve physicians' acknowledgment of laboratory data and their interpretation from the other hand are needed in order to assure quality and safety in the total testing process. © 2013.

  16. 42 CFR 414.509 - Reconsideration of basis for and amount of payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) or § 414.509(a)(3) that the basis for payment for a new test will be gapfilling, CMS posts interim... for a new clinical diagnostic laboratory test. 414.509 Section 414.509 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests...

  17. Pupillometry and Saccades as Objective mTBI Biomark

    DTIC Science & Technology

    2017-06-01

    pupillometers, King-Devick (KD) test and near point of convergence (NPC) rule, respectively. Hundred acute mTBI (≤72 hrs post injury) and 100 age-matched... test  and NPC are also significantly effected in mTBI group.  Task 3: Data Analysis and Report Writing mTBI Control 6/28/2017 1 Medical Research and...U.S. Army Aeromedical Research Laboratory Fort Rucker, Alabama UNCLASSIFIED King-Devick Test 10 *P < 0.0001 Medical Research and Materiel Command U.S

  18. Testing general relativity in space-borne and astronomical laboratories

    NASA Technical Reports Server (NTRS)

    Will, Clifford M.

    1989-01-01

    The current status of space-based experiments and astronomical observations designed to test the theory of general relativity is surveyed. Consideration is given to tests of post-Newtonian gravity, searches for feeble short-range forces and gravitomagnetism, improved measurements of parameterized post-Newtonian parameter values, explorations of post-Newtonian physics, tests of the Einstein equivalence principle, observational tests of post-Newtonian orbital effects, and efforts to detect quadrupole and dipole radiation damping. Recent numerical results are presented in tables.

  19. A study to compare traditional and constructivism-based instruction of a high school biology unit on biosystematics

    NASA Astrophysics Data System (ADS)

    Saigo, Barbara Woodworth

    The researcher collaborated with four high school biology teachers who had been involved for 2-1/2 years in a constructivism-based professional development experience that emphasized teaching for conceptual change and using classroom-based inquiry as a basis for making instructional decisions. The researcher and teachers designed a five-day instructional unit on biosystematics using two contrasting approaches, comprising the treatment variable. The "traditional" unit emphasized lecture, written materials, and some laboratory activities. The "constructivist" unit emphasized a specific, inquiry-based, conceptual change strategy and collaborative learning. The study used a quasi-experimental, factorial design to explore impact of instructional approach (the treatment variable) on student performance (the dependent variable) on repeated measures (three) of a biology concept test. Additional independent variables considered were gender, cumulative GPA, and the section in which students were enrolled. Scores on the biology concept test were compiled for the 3 constructivist sections (N = 44) and the 3 traditional sections (N = 42). Analysis of Covariance (ANCOVA) was applied. The main findings in regard to the primary research question were that instructional approach did not have a significant relationship to immediate post test scores or gain, but that one month after instruction students in the constructivist group demonstrated less loss of gain than those in the traditional group; i.e., their longer-term retention was greater. Also, GPA*instructional approach effects were detected for post-post-test gain. GPA and gender were significantly associated with pre-test, post-test, and post-post scores; however, in terms of change (gain) from pre-test to post-test and pre-test to post-post-test, GPA and gender were not significant effects. Section was a significant effect for all three tests, in terms of both score and gain. Gender*section effects were detected for post-test gain and post-post-test scores.

  20. 42 CFR 414.509 - Reconsideration of basis for and amount of payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) or § 414.509(a)(3) that the basis for payment for a new test will be gapfilling, CMS posts interim... for a new clinical diagnostic laboratory test. 414.509 Section 414.509 Public Health CENTERS FOR... Laboratory Tests § 414.509 Reconsideration of basis for and amount of payment for a new clinical diagnostic...

  1. Analysis of information on rheumatology from a selected Internet forum in the context of the need for telemedicine solutions.

    PubMed

    Szpakowski, Rafał; Maślińska, Maria; Dykowska, Grażyna; Zając, Patrycja

    2015-01-01

    The aim of this study was to determine how often patients and undiagnosed people who complain of musculoskeletal system and rheumatic diseases look for knowledge contained on an Internet forum. Content analysis was used to identify the level of Internet users' activity in the rheumatology section, compared to other areas of medicine. Material included information posted on the Internet forum established at http://medyczka.pl/. The method employed was a quantitative and qualitative analysis of the content. The method was based on qualitative assessment of the first post in each thread presented on the rheumatologic subforum, by assigning keywords, subjectively determined by the researcher, to such a post. For each keyword a specific definition was established, determining a situation in which a given keyword was used. The quantitative analysis qualified rheumatology in the last place in terms of Internet users' activity compared to other branches of medicine. The qualitative assessment of the rheumatologic forum indicated that the three most common keywords were joint pain (32), joints swelling (13), and schoolage (13). The three most common intentional keywords (arranged in order of their decreasing number) were diagnosis based on symptoms (29), interpretation of the laboratory test results (9), and how to deal with symptoms (8). The analysis leads to the conclusion that the rheumatologic subforum, along with other subforums listed above, presents a critically low level of discussion. There is a large disproportion between the number of active and passive forum users, suggesting that numerous individuals search the forum for presented information. Based on the qualitative analysis of the information stocks of the rheumatologic subforum, it was established that most of the questions posted concerned young individuals, who complained of joint pain and swelling, and asked for a possible diagnosis based on the presented symptomatology, interpretation of the laboratory test results and alleviation of disease symptoms.

  2. Analytical performances of food microbiology laboratories - critical analysis of 7 years of proficiency testing results.

    PubMed

    Abdel Massih, M; Planchon, V; Polet, M; Dierick, K; Mahillon, J

    2016-02-01

    Based on the results of 19 food microbiology proficiency testing (PT) schemes, this study aimed to assess the laboratory performances, to highlight the main sources of unsatisfactory analytical results and to suggest areas of improvement. The 2009-2015 results of REQUASUD and IPH PT, involving a total of 48 laboratories, were analysed. On average, the laboratories failed to detect or enumerate foodborne pathogens in 3·0% of the tests. Thanks to a close collaboration with the PT participants, the causes of outliers could be identified in 74% of the cases. The main causes of erroneous PT results were either pre-analytical (handling of the samples, timing of analysis), analytical (unsuitable methods, confusion of samples, errors in colony counting or confirmation) or postanalytical mistakes (calculation and encoding of results). PT schemes are a privileged observation post to highlight analytical problems, which would otherwise remain unnoticed. In this perspective, this comprehensive study of PT results provides insight into the sources of systematic errors encountered during the analyses. This study draws the attention of the laboratories to the main causes of analytical errors and suggests practical solutions to avoid them, in an educational purpose. The observations support the hypothesis that regular participation to PT, when followed by feed-back and appropriate corrective actions, can play a key role in quality improvement and provide more confidence in the laboratory testing results. © 2015 The Society for Applied Microbiology.

  3. 77 FR 71796 - Proposed Data Collections Submitted for Public Comment and Recommendations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-04

    ... pre- and post-analytic laboratory medicine practices that are effective at improving health care... of laboratory tests available certainly warrant such a model. The Laboratory Medicine Best Practices... evidence reviews using published literature, and completed a proof-of-concept test. Results of an extensive...

  4. 10. OBSERVATION POST NO. 3, WEST OF TEST STAND 1A. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. OBSERVATION POST NO. 3, WEST OF TEST STAND 1-A. SOUTH SIDE AND EAST FRONT. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunkers for Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  5. Development of laboratory test methods to replace the simulated high-temperature grout fluidity test.

    DOT National Transportation Integrated Search

    2014-06-01

    This report contains a summary of the research performed to develop a replacement for the high-temperature grout : fluidity (HTGF) test. The HTGF test was employed in the past by FDOT to qualify post-tensioning (PT) grouts for use in : post-tensioned...

  6. Integration of Video-Based Demonstrations to Prepare Students for the Organic Chemistry Laboratory

    NASA Astrophysics Data System (ADS)

    Nadelson, Louis S.; Scaggs, Jonathan; Sheffield, Colin; McDougal, Owen M.

    2015-08-01

    Consistent, high-quality introductions to organic chemistry laboratory techniques effectively and efficiently support student learning in the organic chemistry laboratory. In this work, we developed and deployed a series of instructional videos to communicate core laboratory techniques and concepts. Using a quasi-experimental design, we tested the videos in five traditional laboratory experiments by integrating them with the standard pre-laboratory student preparation presentations and instructor demonstrations. We assessed the influence of the videos on student laboratory knowledge and performance, using sections of students who did not view the videos as the control. Our analysis of pre-quizzes revealed the control group had equivalent scores to the treatment group, while the post-quiz results show consistently greater learning gains for the treatment group. Additionally, the students who watched the videos as part of their pre-laboratory instruction completed their experiments in less time.

  7. Bi-telescopic, deep, simultaneous meteor observations

    NASA Technical Reports Server (NTRS)

    Taff, L. G.

    1986-01-01

    A statistical summary is presented of 10 hours of observing sporadic meteors and two meteor showers using the Experimental Test System of the Lincoln Laboratory. The observatory is briefly described along with the real-time and post-processing hardware, the analysis, and the data reduction. The principal observational results are given for the sporadic meteor zenithal hourly rates. The unique properties of the observatory include twin telescopes to allow the discrimination of meteors by parallax, deep limiting magnitude, good time resolution, and sophisticated real-time and post-observing video processing.

  8. 11. OBSERVATION POST NO. 3, NORTH SIDE AND WEST REAR, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. OBSERVATION POST NO. 3, NORTH SIDE AND WEST REAR, TEST STAND AT RIGHT. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunkers for Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  9. LPT. Low power test control building (TAN641) east facade. Sign ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Low power test control building (TAN-641) east facade. Sign says "Energy and Systems Technology Laboratory, INEL" (Post-ANP-use). Camera facing west. INEEL negative no. HD-40-3-2 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  10. Drop Testing Representative Multi-Canister Overpacks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snow, Spencer D.; Morton, Dana K.

    The objective of the work reported herein was to determine the ability of the Multi- Canister Overpack (MCO) canister design to maintain its containment boundary after an accidental drop event. Two test MCO canisters were assembled at Hanford, prepared for testing at the Idaho National Engineering and Environmental Laboratory (INEEL), drop tested at Sandia National Laboratories, and evaluated back at the INEEL. In addition to the actual testing efforts, finite element plastic analysis techniques were used to make both pre-test and post-test predictions of the test MCOs structural deformations. The completed effort has demonstrated that the canister design is capablemore » of maintaining a 50 psig pressure boundary after drop testing. Based on helium leak testing methods, one test MCO was determined to have a leakage rate not greater than 1x10 -5 std cc/sec (prior internal helium presence prevented a more rigorous test) and the remaining test MCO had a measured leakage rate less than 1x10 -7 std cc/sec (i.e., a leaktight containment) after the drop test. The effort has also demonstrated the capability of finite element methods using plastic analysis techniques to accurately predict the structural deformations of canisters subjected to an accidental drop event.« less

  11. Performance criteria and quality indicators for the post-analytical phase.

    PubMed

    Sciacovelli, Laura; Aita, Ada; Padoan, Andrea; Pelloso, Michela; Antonelli, Giorgia; Piva, Elisa; Chiozza, Maria Laura; Plebani, Mario

    2016-07-01

    Quality indicators (QIs) used as performance measurements are an effective tool in accurately estimating quality, identifying problems that may need to be addressed, and monitoring the processes over time. In Laboratory Medicine, QIs should cover all steps of the testing process, as error studies have confirmed that most errors occur in the pre- and post-analytical phase of testing. Aim of the present study is to provide preliminary results on QIs and related performance criteria in the post-analytical phase. This work was conducted according to a previously described study design based on the voluntary participation of clinical laboratories in the project on QIs of the Working Group "Laboratory Errors and Patient Safety" (WG-LEPS) of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). Overall, data collected highlighted an improvement or stability in performances over time for all reported indicators thus demonstrating that the use of QIs is effective in the quality improvement strategy. Moreover, QIs data are an important source for defining the state-of-the-art concerning the error rate in the total testing process. The definition of performance specifications based on the state-of-the-art, as suggested by consensus documents, is a valuable benchmark point in evaluating the performance of each laboratory. Laboratory tests play a relevant role in the monitoring and evaluation of the efficacy of patient outcome thus assisting clinicians in decision-making. Laboratory performance evaluation is therefore crucial to providing patients with safe, effective and efficient care.

  12. Implementation of a new 'community' laboratory CD4 service in a rural health district in South Africa extends laboratory services and substantially improves local reporting turnaround time.

    PubMed

    Coetzee, L M; Cassim, N; Glencross, D K

    2015-12-16

    The CD4 integrated service delivery model (ITSDM) provides for reasonable access to pathology services across South Africa (SA) by offering three new service tiers that extend services into remote, under-serviced areas. ITSDM identified Pixley ka Seme as such an under-serviced district. To address the poor service delivery in this area, a new ITSDM community (tier 3) laboratory was established in De Aar, SA. Laboratory performance and turnaround time (TAT) were monitored post implementation to assess the impact on local service delivery. Using the National Health Laboratory Service Corporate Data Warehouse, CD4 data were extracted for the period April 2012-July 2013 (n=11,964). Total mean TAT (in hours) was calculated and pre-analytical and analytical components assessed. Ongoing testing volumes, as well as external quality assessment performance across ten trials, were used to indicate post-implementation success. Data were analysed using Stata 12. Prior to the implementation of CD4 testing at De Aar, the total mean TAT was 20.5 hours. This fell to 8.2 hours post implementation, predominantly as a result of a lower pre-analytical mean TAT reducing from a mean of 18.9 to 1.8 hours. The analytical testing TAT remained unchanged after implementation and monthly test volumes increased by up to 20%. External quality assessment indicated adequate performance. Although subjective, questionnaires sent to facilities reported improved service delivery. Establishing CD4 testing in a remote community laboratory substantially reduces overall TAT. Additional community CD4 laboratories should be established in under-serviced areas, especially where laboratory infrastructure is already in place.

  13. Spectral analysis software improves confidence in plant and soil water stable isotope analyses performed by isotope ratio infrared spectroscopy (IRIS).

    PubMed

    West, A G; Goldsmith, G R; Matimati, I; Dawson, T E

    2011-08-30

    Previous studies have demonstrated the potential for large errors to occur when analyzing waters containing organic contaminants using isotope ratio infrared spectroscopy (IRIS). In an attempt to address this problem, IRIS manufacturers now provide post-processing spectral analysis software capable of identifying samples with the types of spectral interference that compromises their stable isotope analysis. Here we report two independent tests of this post-processing spectral analysis software on two IRIS systems, OA-ICOS (Los Gatos Research Inc.) and WS-CRDS (Picarro Inc.). Following a similar methodology to a previous study, we cryogenically extracted plant leaf water and soil water and measured the δ(2)H and δ(18)O values of identical samples by isotope ratio mass spectrometry (IRMS) and IRIS. As an additional test, we analyzed plant stem waters and tap waters by IRMS and IRIS in an independent laboratory. For all tests we assumed that the IRMS value represented the "true" value against which we could compare the stable isotope results from the IRIS methods. Samples showing significant deviations from the IRMS value (>2σ) were considered to be contaminated and representative of spectral interference in the IRIS measurement. Over the two studies, 83% of plant species were considered contaminated on OA-ICOS and 58% on WS-CRDS. Post-analysis, spectra were analyzed using the manufacturer's spectral analysis software, in order to see if the software correctly identified contaminated samples. In our tests the software performed well, identifying all the samples with major errors. However, some false negatives indicate that user evaluation and testing of the software are necessary. Repeat sampling of plants showed considerable variation in the discrepancies between IRIS and IRMS. As such, we recommend that spectral analysis of IRIS data must be incorporated into standard post-processing routines. Furthermore, we suggest that the results from spectral analysis be included when reporting stable isotope data from IRIS. Copyright © 2011 John Wiley & Sons, Ltd.

  14. An investigation into the effectiveness of problem-based learning in a physical chemistry laboratory course

    NASA Astrophysics Data System (ADS)

    Gürses, Ahmet; Açıkyıldız, Metin; Doğar, Çetin; Sözbilir, Mustafa

    2007-04-01

    The aim of this study was to investigate the effectiveness of a problem-based learning (PBL) approach in a physical chemistry laboratory course. The parameters investigated were students’ attitudes towards a chemistry laboratory course, scientific process skills of students and their academic achievement. The design of the study was one group pre-test post-test. Four experiments, covering the topics adsorption, viscosity, surface tension and conductivity were performed using a PBL approach in the fall semester of the 2003/04 academic year at Kazim Karabekir Education Faculty of Atatürk University. Each experiment was done over a three week period. A total of 40 students, 18 male and 22 female, participated in the study. Students took the Physical Chemistry Laboratory Concept Test (PCLCT), Attitudes towards Chemistry Laboratory (ATCL) questionnaire and Science Process Skills Test (SPST) as pre and post-tests. In addition, the effectiveness of the PBL approach was also determined through four different scales; Scales Specific to Students’ Views of PBL. A statistically significant difference between the students’ academic achievement and scientific process skills at p

  15. Reproduction of post-weaning multi-systemic wasting syndrome in an animal disease model as a tool for vaccine testing under controlled conditions.

    PubMed

    McKillen, John; McNair, Irene; Lagan, Paula; McKay, Karen; McClintock, Julie; Casement, Veronica; Charreyre, Catherine; Allan, Gordon

    2016-04-01

    Snatch farrowed, colostrum deprived piglets were inoculated with different combinations of porcine circovirus 2, porcine parvovirus and Erysipelothrix rhusiopathiae candidate vaccines. 10 piglets were mock-vaccinated. Following virus challenge with a combined porcine circovirus 2/porcine parvovirus inoculum, all animals were monitored and samples taken for serology, immunohistochemistry and qPCR. At 24 dpc all non-vaccinated animals remaining were exhibiting signs of post-weaning multi-systemic wasting syndrome which was confirmed by laboratory analysis. Details of the study, analysis of samples and performance of the candidate vaccines are described. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Human rabies in India: an audit from a rabies diagnostic laboratory.

    PubMed

    Mani, Reeta Subramaniam; Anand, Ashwini Manoor; Madhusudana, Shampur Narayan

    2016-04-01

    Rabies, an acute progressive encephalomyelitis, continues to be a serious public health problem in India and many other countries in Asia and Africa. The low level of commitment to rabies control is partly attributable to challenges in laboratory diagnosis and lack of adequate surveillance to indicate the disease burden. A laboratory audit of human rabies cases was undertaken to disseminate information on the clinical, demographic, prophylactic and most importantly the laboratory diagnostic aspects of rabies. A retrospective analysis of all clinically suspected human rabies cases, whose samples were received at a rabies diagnostic laboratory in South India in the last 3 years, was performed. Clinical and demographic details of patients were obtained. The clinical samples included cerebrospinal fluid (CSF), serum, saliva and nuchal skin biopsy collected antemortem, and brain tissue obtained post-mortem. Various laboratory tests were performed for diagnosis. Clinical samples from 128 patients with suspected rabies, from 11 states in India, were received for diagnostic confirmation. About 94% of the victims reported dog-bites, more than a third of them were children and most of the victims did not receive adequate post-exposure prophylaxis. Antemortem confirmation of rabies by a combination of laboratory diagnostic assays (detection of viral RNA in CSF, skin and saliva, and neutralising antibodies in CSF) could be achieved in 40.6% cases. Increasing awareness about adequate post-exposure prophylaxis, additional rabies diagnostic facilities, and enhanced human and animal rabies surveillance to indicate the true disease burden are essential to control this fatal disease. © 2016 John Wiley & Sons Ltd.

  17. IVGEN Post Flight Analysis

    NASA Technical Reports Server (NTRS)

    Mcquillen, John; Brown, Dan; Hussey, Sam; Zoldak, John

    2014-01-01

    The Intravenous Fluid Generation (IVGEN) Experiment was a technology demonstration experiment that purified ISS potable water, mixed it with salt, and transferred it through a sterilizing filter. On-orbit performance was verified as appropriate and two 1.5 l bags of normal saline solution were returned to earth for post-flight testing by a FDA certified laboratory for compliance with United States Pharmacopiea (USP) standards. Salt concentration deviated from required values and an analysis identified probable causes. Current efforts are focused on Total Organic Content (TOC) testing, and shelf life.The Intravenous Fluid Generation (IVGEN) Experiment demonstrated the purification of ISS potable water, the mixing of the purified water with sodium chloride, and sterilization of the solution via membrane filtration. On-orbit performance was monitored where feasible and two 1.5-liter bags of normal saline solution were returned to earth for post-flight testing by a FDA-registered laboratory for compliance with United States Pharmacopeia (USP)standards [1]. Current efforts have been focused on challenge testing with identified [2] impurities (total organic-carbon), and shelf life testing. The challenge testing flowed known concentrations of contaminants through the IVGEN deionizing cartridge and membrane filters to test their effectiveness. One finding was that the filters and DI-resin themselves contribute to the contaminant load during initial startup, suggesting that the first 100 ml of fluid be discarded. Shelf life testing is ongoing and involves periodic testing of stored DI cartridges and membrane filters that are capped and sealed in hermetic packages. The testing is conducted at six month intervals measuring conductivity and endotoxins in the effluent. Currently, the packaging technique has been successfully demonstrated for one year of storage testing. The USP standards specifies that the TOC be conducted at point of generation as opposed to point of consumption. Samples were generated and shipped to an FDA facility however, testing determined that the samples failed the TOC specification with most likely due to leaching from the sample container. Shelf life testing is examining packaging techniques and periodic testing of samples of DI cartridges that are capped and sealed in hermetic packages. Periodic testing of the purified water output will be conducted at six month intervals.

  18. Results of advanced battery technology evaluations for electric vehicle applications

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    1992-10-01

    Advanced battery technology evaluations are performed under simulated electric-vehicle operating conditions at the Analysis and Diagnostic Laboratory (ADL) of Argonne National Laboratory. The ADL results provide insight into those factors that limit battery performance and life. The ADL facilities include a test laboratory to conduct battery experimental evaluations under simulated application conditions and a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. This paper summarizes the performance characterizations and life evaluations conducted during 1991-1992 on both single cells and multi-cell modules that encompass eight battery technologies (Na/S, Li/MS (M=metal), Ni/MH, Ni/Cd, Ni/Zn, Ni/Fe, Zn/Br, and Pb-acid). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division, and the Electric Power Research Institute. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The results help identify the most-promising R&D approaches for overcoming battery limitations, and provide battery users, developers, and program managers with a measure of the progress being made in battery R&D programs, a comparison of battery technologies, and basic data for modeling.

  19. Thermal Analysis in Support of the Booster Separation Motor Crack Investigation

    NASA Technical Reports Server (NTRS)

    Davis, Darrell; Prickett, Terry; Turner, Larry D. (Technical Monitor)

    2001-01-01

    During a post-test inspection of a Booster Separation Motor (BSM) from a Lot Acceptance Test (LAT), a crack was noticed in the graphite throat. Since this was an out-of-family occurrence, an investigation team was formed to determine the cause of the crack. This paper will describe thermal analysis techniques used in support of this investigation. Models were generated to predict gradients in nominal motor conditions, as well as potentially anomalous conditions. Analysis was also performed on throats that were tested in the Laser Hardened Material Evaluation Laboratory (LHMEL). Some of these throats were pre-cracked, while others represented configurations designed to amplify effects of thermal stresses. Results from these analyses will be presented in this paper.

  20. Thermal Analysis in Support of the Booster Separation Motor Crack Investigation

    NASA Technical Reports Server (NTRS)

    Davis, Darrell; Prickett, Terry

    2002-01-01

    During a post-test inspection of a Booster Separation Motor (BSM) from a Lot Acceptance Test (LAT), a crack was noticed in the graphite throat. Since this was an out-of-family occurrence, an investigation team was formed to determine the cause of the crack. This paper will describe thermal analysis techniques used in support of this investigation. Models were generated to predict gradients in nominal motor conditions, as well as potentially anomalous conditions. Analysis was also performed on throats that were tested in the Laser Hardened Material Evaluation Laboratory (LHMEL). Some of these throats were pre-cracked, while others represented configurations designed to amplify effects of thermal stresses. Results from these analyses will be presented in this paper.

  1. Radiation and temperature effects on LDEF fiber optic samples

    NASA Technical Reports Server (NTRS)

    Johnston, A. R.; Hartmayer, R.; Bergman, L. A.

    1993-01-01

    Results obtained from the JPL Fiber Optics Long Duration Exposure Facility (LDEF) Experiment since the June 1991 Experimenters' Workshop are addressed. Radiation darkening of laboratory control samples and the subsequent annealing was measured in the laboratory for the control samples. The long-time residual loss was compared to the LDEF flight samples and found to be in agreement. The results of laboratory temperature tests on the flight samples, extending over a period of about nine years, including the pre-flight and post-flight analysis periods, are described. The temperature response of the different cable samples varies widely, and appears in two samples to be affected by polymer aging. Conclusions to date are summarized.

  2. TRITIUM LABORATORY, TRA666, INTERIOR. MAIN FLOOR. CONTROL ROOM ENCLOSURE AT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    TRITIUM LABORATORY, TRA-666, INTERIOR. MAIN FLOOR. CONTROL ROOM ENCLOSURE AT CENTER OF VIEW. SIGN ABOVE DOOR SAYS "HYDRAULIC TEST FACILITY CONTROL ROOM." SIGN IN WINDOW SAYS "EATING AREA." "EVACUATION AND EMERGENCY INFORMATION" IS POSTED ON CABINET AT LEFT OF VIEW. INL NEGATIVE NO. HD30-2-3. Mike Crane, Photographer, 6/2001 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  3. PIE on Safety-Tested Loose Particles from Irradiated Compact 4-4-2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunn, John D.; Gerczak, Tyler J.; Morris, Robert Noel

    2016-04-01

    Post-irradiation examination (PIE) is being performed in support of tristructural isotropic (TRISO) coated particle fuel development and qualification for High Temperature Gas-cooled Reactors (HTGRs). This work is sponsored by the Department of Energy Office of Nuclear Energy (DOE-NE) through the Advanced Reactor Technologies (ART) Office under the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program. The AGR-1 experiment was the first in a series of TRISO fuel irradiation tests initiated in 2006. The AGR-1 TRISO particles and fuel compacts were fabricated at Oak Ridge National Laboratory (ORNL) in 2006 using laboratory-scale equipment and irradiated for 3 years in themore » Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) to demonstrate and evaluate fuel performance under HTGR irradiation conditions. Post-irradiation examination was performed at INL and ORNL to study how the fuel behaved during irradiation, and to test fuel performance during exposure to elevated temperatures at or above temperatures that could occur during a depressurized conduction cooldown event. This report summarizes safety testing and post-safety testing PIE conducted at ORNL on loose particles extracted from irradiated AGR-1 Compact 4-4-2.« less

  4. Telehealth physician oversight over direct to consumer testing: doctors working with patients towards patient empowerment.

    PubMed

    Chung, Rick

    2012-06-01

    Patient empowerment has increased the demand for direct to consumer (DTC) laboratory testing. Multiple professional societies and advocacy groups have raised concerns over how DTC laboratory testing is being offered to consumers without proper physician oversight. Physician telehealth services can properly oversee DTC laboratory testing in a safe and medically sound manner. Using telehealth protocols and standards established by professional health organizations and state regulators, physician telehealth oversight in DTC laboratory test ordering can be effective to increase patient access to healthcare services. With proper physician oversight in test interpretation, post-test counseling, and information collaboration, DTC laboratory testing can remain a reliable and convenient option for consumers. Working within the channel of distribution of most DTC laboratory testing, physician telehealth services can properly oversee DTC laboratory testing in a safe and medically sound manner to ensure that proper test interpretation, counseling, and information collaboration are achieved. Physician telehealth services can properly oversee DTC laboratory testing to ensure that proper test interpretation, counseling, and information collaboration are achieved.

  5. Effect of implementing instructional videos in a physical examination course: an alternative paradigm for chiropractic physical examination teaching.

    PubMed

    Zhang, Niu; Chawla, Sudeep

    2012-01-01

    This study examined the effect of implementing instructional video in ophthalmic physical examination teaching on chiropractic students' laboratory physical examination skills and written test results. Instructional video clips of ophthalmic physical examination, consisting of both standard procedures and common mistakes, were created and used for laboratory teaching. The video clips were also available for student review after class. Students' laboratory skills and written test results were analyzed and compared using one-way analysis of variance (ANOVA) and post hoc multiple comparison tests among three study cohorts: the comparison cohort who did not utilize the instructional videos as a tool, the standard video cohort who viewed only the standard procedure of video clips, and the mistake-referenced video cohort who viewed video clips containing both standard procedure and common mistakes. One-way ANOVA suggested a significant difference of lab results among the three cohorts. Post hoc multiple comparisons further revealed that the mean scores of both video cohorts were significantly higher than that of the comparison cohort (p < .001). There was, however, no significant difference of the mean scores between the two video cohorts (p > .05). However, the percentage of students having a perfect score was the highest in the mistake-referenced video cohort. There was no significant difference of written test scores among all three cohorts (p > .05). The instructional video of the standard procedure improves chiropractic students' ophthalmic physical examination skills, which may be further enhanced by implementing a mistake-referenced instructional video.

  6. Low Temperature Power Coating (LTPC) Phase 2 Laboratory Test Plan and Procedures for PACAF (Rev D)

    DTIC Science & Technology

    2018-03-20

    Δa*, LTPC Phase II Laboratory Test Plan and Procedures Rev D (CDRL A004) BATTELLE | 20 March 2018 | 6 Δb* and ΔE will be calculated post ...BATTELLE | CONTRACT NUMBER: FA8532-17-C-0008 (CDRL A004) LTPC Phase II Laboratory Test Plan and Procedures (Rev D) Prepared by... Test Plan and Procedures Rev D (CDRL A004) BATTELLE | 20 March 2018 | i List of Acronyms AGE Aircraft Ground Equipment ASTM American

  7. Challenges of Maintaining Good Clinical Laboratory Practices in Low-Resource Settings:  A Health Program Evaluation Framework Case Study From East Africa.

    PubMed

    Zhang, Helen L; Omondi, Michael W; Musyoka, Augustine M; Afwamba, Isaac A; Swai, Remigi P; Karia, Francis P; Muiruri, Charles; Reddy, Elizabeth A; Crump, John A; Rubach, Matthew P

    2016-08-01

    Using a clinical research laboratory as a case study, we sought to characterize barriers to maintaining Good Clinical Laboratory Practice (GCLP) services in a developing world setting. Using a US Centers for Disease Control and Prevention framework for program evaluation in public health, we performed an evaluation of the Kilimanjaro Christian Medical Centre-Duke University Health Collaboration clinical research laboratory sections of the Kilimanjaro Clinical Research Institute in Moshi, Tanzania. Laboratory records from November 2012 through October 2014 were reviewed for this analysis. During the 2-year period of study, seven instrument malfunctions suspended testing required for open clinical trials. A median (range) of 9 (1-55) days elapsed between instrument malfunction and biomedical engineer service. Sixteen (76.1%) of 21 suppliers of reagents, controls, and consumables were based outside Tanzania. Test throughput among laboratory sections used a median (range) of 0.6% (0.2%-2.7%) of instrument capacity. Five (55.6%) of nine laboratory technologists left their posts over 2 years. These findings demonstrate that GCLP laboratory service provision in this setting is hampered by delays in biomedical engineer support, delays and extra costs in commodity procurement, low testing throughput, and high personnel turnover. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Trauma surgeon becomes consultant: evaluation of a protocol for management of intermediate-level trauma patients.

    PubMed

    Fallon, Sara C; Delemos, David; Christopher, Daniel; Frost, Mary; Wesson, David E; Naik-Mathuria, Bindi

    2014-01-01

    At our level 1 pediatric trauma center, 9-54 intermediate-level ("level 2") trauma activations are received per month. Previously, the surgery team was required to respond to and assume responsibility for all patients who had "level 2" trauma activations. In 8/2011, we implemented a protocol where the emergency room (ER) physician primarily manages these patients with trauma consultation for surgical evaluation or admission. The purpose of this study was to prospectively evaluate the effects of the new protocol to ensure that patient safety and quality of care were maintained. We compared outcomes of patients treated PRE-implementation (10/2010-7/2011) and POST-implementation (9/2011-5/2012), including surgeon consultation rate, utilization of imaging and laboratory testing, ER length of stay, admission rate, and missed injuries or readmissions. Statistical analysis included chi-square and Student's t-test. We identified 472 patients: 179 in the PRE and 293 in the POST period. The populations had similar baseline clinical characteristics. The surgical consultation rate in the POST period was only 42%, with no missed injuries or readmissions. The ER length of stay did not change. However, in the POST period there were significant decreases in the admission rate (73% to 44%) and the mean number of CT scans (1.4 to 1), radiographs (2.4 to 1.7), and laboratory tests (5.1 to 3.3) ordered in the emergency room (all p<0.001). Intermediate-level pediatric trauma patients can be efficiently and safely managed by pediatric emergency room physicians, with surgical consultation only as needed. The protocol change improved resource utilization by decreasing testing and admissions and streamlining resident utilization in an era of reduced duty hours. © 2014.

  9. Data analysis techniques used at the Oak Ridge Y-12 plant flywheel evaluation laboratory

    NASA Astrophysics Data System (ADS)

    Steels, R. S., Jr.; Babelay, E. F., Jr.

    1980-07-01

    Some of the more advanced data analysis techniques applied to the problem of experimentally evaluating the performance of high performance composite flywheels are presented. Real time applications include polar plots of runout with interruptions relating to balance and relative motions between parts, radial growth measurements, and temperature of the spinning part. The technique used to measure torque applied to a containment housing during flywheel failure is also presented. The discussion of pre and post test analysis techniques includes resonant frequency determination with modal analysis, waterfall charts, and runout signals at failure.

  10. HIV among Women

    MedlinePlus

    ... Determination of Need Requests Pre-Exposure Prophylaxis (PrEP) Post-Exposure Prophylaxis (PEP) HIV Treatment as Prevention Condoms HIV in the Workplace HIV Testing Laboratory Tests Home Tests Testing in Nonclinical Settings CLIA Certificate ...

  11. HIV Among Asians

    MedlinePlus

    ... Determination of Need Requests Pre-Exposure Prophylaxis (PrEP) Post-Exposure Prophylaxis (PEP) HIV Treatment as Prevention Condoms HIV in the Workplace HIV Testing Laboratory Tests Home Tests Testing in Nonclinical Settings CLIA Certificate ...

  12. DebriSat Pre Preshot Laboratory Analyses

    DTIC Science & Technology

    2015-03-27

    plate on up range side. MLI Down range Up range SBU Marking Witness Plates: Post Test (protected) 17 Surfaces of samples under Whipple plates are...s SBU Marking Witness Plates Post Test : Whipple Plates 59 Bottom Middle Top Up range is to the right – note sharp band of deposits on up range side...Marking Hold down plates: Post test 63 Up range Note larger deposit fragments on the down range plate. Similar larger deposits were observed on

  13. ETR BUILDING, TRA642, INTERIOR. BASEMENT. ROLLUP DOOR TO CUBICLE POSTS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ETR BUILDING, TRA-642, INTERIOR. BASEMENT. ROLLUP DOOR TO CUBICLE POSTS CAUTION SIGNS BECAUSE OF SODIUM HAZARD WITHIN. INL NEGATIVE NO. HD24-3-1. Mike Crane, Photographer, 11/2000 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  14. The effects of total laboratory automation on the management of a clinical chemistry laboratory. Retrospective analysis of 36 years.

    PubMed

    Sarkozi, Laszlo; Simson, Elkin; Ramanathan, Lakshmi

    2003-03-01

    Thirty-six years of data and history of laboratory practice at our institution has enabled us to follow the effects of analytical automation, then recently pre-analytical and post-analytical automation on productivity, cost reduction and enhanced quality of service. In 1998, we began the operation of a pre- and post-analytical automation system (robotics), together with an advanced laboratory information system to process specimens prior to analysis, deliver them to various automated analytical instruments, specimen outlet racks and finally to refrigerated stockyards. By the end of 3 years of continuous operation, we compared the chemistry part of the system with the prior 33 years and quantitated the financial impact of the various stages of automation. Between 1965 and 2000, the Consumer Price Index increased by a factor of 5.5 in the United States. During the same 36 years, at our institution's Chemistry Department the productivity (indicated as the number of reported test results/employee/year) increased from 10,600 to 104,558 (9.3-fold). When expressed in constant 1965 dollars, the total cost per test decreased from 0.79 dollars to 0.15 dollars. Turnaround time for availability of results on patient units decreased to the extent that Stat specimens requiring a turnaround time of <1 h do not need to be separately prepared or prioritized on the system. Our experience shows that the introduction of a robotics system for perianalytical automation has brought a large improvement in productivity together with decreased operational cost. It enabled us to significantly increase our workload together with a reduction of personnel. In addition, stats are handled easily and there are benefits such as safer working conditions and improved sample identification, which are difficult to quantify at this stage.

  15. HIV among Transgender People

    MedlinePlus

    ... Determination of Need Requests Pre-Exposure Prophylaxis (PrEP) Post-Exposure Prophylaxis (PEP) HIV Treatment as Prevention Condoms HIV in the Workplace HIV Testing Laboratory Tests Home Tests Testing in Nonclinical Settings CLIA Certificate ...

  16. HIV Risk and Prevention

    MedlinePlus

    ... Determination of Need Requests Pre-Exposure Prophylaxis (PrEP) Post-Exposure Prophylaxis (PEP) HIV Treatment as Prevention Condoms HIV in the Workplace HIV Testing Laboratory Tests Home Tests Testing in Nonclinical Settings CLIA Certificate ...

  17. Cost effectiveness of adopted quality requirements in hospital laboratories.

    PubMed

    Hamza, Alneil; Ahmed-Abakur, Eltayib; Abugroun, Elsir; Bakhit, Siham; Holi, Mohamed

    2013-01-01

    The present study was designed in quasi-experiment to assess adoption of the essential clauses of particular clinical laboratory quality management requirements based on international organization for standardization (ISO 15189) in hospital laboratories and to evaluate the cost effectiveness of compliance to ISO 15189. The quality management intervention based on ISO 15189 was conceded through three phases; pre - intervention phase, Intervention phase and Post-intervention phase. In pre-intervention phase the compliance to ISO 15189 was 49% for study group vs. 47% for control group with P value 0.48, while the post intervention results displayed 54% vs. 79% for study group and control group respectively in compliance to ISO 15189 and statistically significant difference (P value 0.00) with effect size (Cohen's d) of (0.00) in pre-intervention phase and (0.99) in post - intervention phase. The annual average cost per-test for the study group and control group was 1.80 ± 0.25 vs. 1.97 ± 0.39, respectively with P value 0.39 whereas the post-intervention results showed that the annual average total costs per-test for study group and control group was 1.57 ± 0.23 vs 2.08 ± 0.38, P value 0.019 respectively, with cost-effectiveness ratio of (0.88) in pre -intervention phase and (0.52) in post-intervention phase. The planned adoption of quality management requirements (QMS) in clinical laboratories had great effect to increase the compliance percent with quality management system requirement, raise the average total cost effectiveness, and improve the analytical process capability of the testing procedure.

  18. HIV/AIDS among African Americans

    MedlinePlus

    ... Determination of Need Requests Pre-Exposure Prophylaxis (PrEP) Post-Exposure Prophylaxis (PEP) HIV Treatment as Prevention Condoms HIV in the Workplace HIV Testing Laboratory Tests Home Tests Testing in Nonclinical Settings CLIA Certificate ...

  19. Evaluation of analytical errors in a clinical chemistry laboratory: a 3 year experience.

    PubMed

    Sakyi, As; Laing, Ef; Ephraim, Rk; Asibey, Of; Sadique, Ok

    2015-01-01

    Proficient laboratory service is the cornerstone of modern healthcare systems and has an impact on over 70% of medical decisions on admission, discharge, and medications. In recent years, there is an increasing awareness of the importance of errors in laboratory practice and their possible negative impact on patient outcomes. We retrospectively analyzed data spanning a period of 3 years on analytical errors observed in our laboratory. The data covered errors over the whole testing cycle including pre-, intra-, and post-analytical phases and discussed strategies pertinent to our settings to minimize their occurrence. We described the occurrence of pre-analytical, analytical and post-analytical errors observed at the Komfo Anokye Teaching Hospital clinical biochemistry laboratory during a 3-year period from January, 2010 to December, 2012. Data were analyzed with Graph Pad Prism 5(GraphPad Software Inc. CA USA). A total of 589,510 tests was performed on 188,503 outpatients and hospitalized patients. The overall error rate for the 3 years was 4.7% (27,520/58,950). Pre-analytical, analytical and post-analytical errors contributed 3.7% (2210/58,950), 0.1% (108/58,950), and 0.9% (512/58,950), respectively. The number of tests reduced significantly over the 3-year period, but this did not correspond with a reduction in the overall error rate (P = 0.90) along with the years. Analytical errors are embedded within our total process setup especially pre-analytical and post-analytical phases. Strategic measures including quality assessment programs for staff involved in pre-analytical processes should be intensified.

  20. Immediate assessment of performance of medical laboratory scientists following a 10-day malaria microscopy training programme in Nigeria.

    PubMed

    Aiyenigba, Bolatito; Ojo, Abiodun; Aisiri, Adolor; Uzim, Justus; Adeusi, Oluwole; Mwenesi, Halima

    2017-01-01

    Rapid and precise diagnosis of malaria is an essential element in effective case management and control of malaria. Malaria microscopy is used as the gold standard for malaria diagnosis, however results remain poor as positivity rate in Nigeria is consistently over 90%. The United States President's Malaria Initiative (PMI) through the Malaria Action Program for States (MAPS) supported selected states in Nigeria to build capacity for malaria microscopy. This study demonstrates the effectiveness of in-service training on malaria microscopy amongst medical laboratory scientists. The training was based on the World Health Organization (WHO) basic microscopy training manual. The 10-day training utilized a series of didactic lectures and examination of teaching slides using a CX 21 Olympus binocular microscope. All 108 medical laboratory scientists trained from 2012 to 2015 across five states in Nigeria supported by PMI were included in the study. Evaluation of the training using a pre-and post-test method was based on written test questions; reading photographic slide images of malaria parasites; and prepared slides. There was a significant improvement in the mean written pre-and post-tests scores from 37.9% (95% CI 36.2-39.6%) to 70.7% (95% CI 68.4-73.1%) ( p  < 0.001). The mean counting post-test score improved significantly from 4.2% (95% CI 2.6-5.7%) to 27.9% (95% CI 25.3-30.5%) ( p  < 0.001). Mean post-test score for computer-based picture speciation test (63.0%) and picture detection test (89.2%) were significantly higher than the mean post-test score for slide reading speciation test (38.3%) and slide reading detection test (70.7%), p  < 0.001 in both cases. Parasite detection and speciation using enhanced visual imaging was significantly improved compared with using direct microscopy. Regular in-service training and provision of functional and high resolution microscopes are needed to ensure quality routine malaria microscopy.

  1. Submission of FeCrAl Feedstock for Support of AFC ATR-2 Irradiations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Field, Kevin G.; Barrett, Kristine E.; Sun, Zhiqian

    The Advanced Test Reactor (ATR) is currently being used to test accident tolerant fuel (ATF) forms destined for commercial nuclear power plant deployment. One irradiation program using the ATR for ATF concepts, Accident Tolerant Fuel-2 (ATF-2), is a water loop irradiation test using miniaturized fuel pins as test articles. This complicated testing configuration requires a series of pre-test experiments and verification including a flowing loop autoclave test and a sensor qualification test (SQT) prior to full test train deployment within the ATR. In support of the ATF-2 irradiation program, Oak Ridge National Laboratory (ORNL) has supplied two different Generation IImore » FeCrAl alloys in rod stock form to Idaho National Laboratory (INL). These rods will be machined into dummy pins for deployment in the autoclave test and SQT. Post-test analysis of the dummy pins will provide initial insight into the performance of Generation II FeCrAl alloys in the ATF-2 irradiation experiment as well as within a commercial nuclear reactor.« less

  2. HIV Among People Aged 50 and Over

    MedlinePlus

    ... Determination of Need Requests Pre-Exposure Prophylaxis (PrEP) Post-Exposure Prophylaxis (PEP) HIV Treatment as Prevention Condoms HIV in the Workplace HIV Testing Laboratory Tests Home Tests Testing in Nonclinical Settings CLIA Certificate ...

  3. HIV among Pregnant Women, Infants, and Children

    MedlinePlus

    ... Determination of Need Requests Pre-Exposure Prophylaxis (PrEP) Post-Exposure Prophylaxis (PEP) HIV Treatment as Prevention Condoms HIV in the Workplace HIV Testing Laboratory Tests Home Tests Testing in Nonclinical Settings CLIA Certificate ...

  4. HIV among Gay and Bisexual Men

    MedlinePlus

    ... Determination of Need Requests Pre-Exposure Prophylaxis (PrEP) Post-Exposure Prophylaxis (PEP) HIV Treatment as Prevention Condoms HIV in the Workplace HIV Testing Laboratory Tests Home Tests Testing in Nonclinical Settings CLIA Certificate ...

  5. Woodstove smoke and CO emissions: comparison of reference methods with the VIP sampler.

    PubMed

    Jaasma, D R; Champion, M C; Shelton, J W

    1990-06-01

    A new field sampler has been developed for measuring the particulate matter (PM) and carbon monoxide emissions of woodburning stoves. Particulate matter is determined by carbon balance and the workup of a sample train which is similar to a room-temperature EPA Method 5G train. A steel tank, initially evacuated, serves as the motive force for sampling and also accumulates a gas sample for post-test analysis of time-averaged stack CO and CO2 concentrations. Workup procedures can be completed within 72 hours of sampler retrieval. The system has been compared to reference methods in two laboratory test series involving six different woodburning appliances and two independent laboratories. The correlation of field sampler emission rates and reference method rates is strong.

  6. Woodstove smoke and CO emissions: Comparison of reference methods with the VIP sampler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jaasma, D.R.; Champion, M.C.; Shelton, J.W.

    1990-06-01

    A new field sampler has been developed for measuring the particulate matter (PM) and carbon monoxide emissions of woodburning stoves. Particulate matter is determined by carbon balance and the workup of a sample train which is similar to a room-temperature EPA Method 5G train. A steel tank, initially evacuated, serves as the motive force for sampling and also accumulates a gas sample for post-test analysis of time-averaged stack CO and CO{sub 2} concentrations. Workup procedures can be completed within 72 hours of sampler retrieval. The system has been compared to reference methods in two laboratory test series involving six differentmore » woodburning appliances and two independent laboratories. The correlation of field sampler emission rates and reference method rates is strong.« less

  7. Education on electrical phenomena involved in electroporation-based therapies and treatments: a blended learning approach.

    PubMed

    Čorović, Selma; Mahnič-Kalamiza, Samo; Miklavčič, Damijan

    2016-04-07

    Electroporation-based applications require multidisciplinary expertise and collaboration of experts with different professional backgrounds in engineering and science. Beginning in 2003, an international scientific workshop and postgraduate course electroporation based technologies and treatments (EBTT) has been organized at the University of Ljubljana to facilitate transfer of knowledge from leading experts to researches, students and newcomers in the field of electroporation. In this paper we present one of the integral parts of EBTT: an e-learning practical work we developed to complement delivery of knowledge via lectures and laboratory work, thus providing a blended learning approach on electrical phenomena involved in electroporation-based therapies and treatments. The learning effect was assessed via a pre- and post e-learning examination test composed of 10 multiple choice questions (i.e. items). The e-learning practical work session and both of the e-learning examination tests were carried out after the live EBTT lectures and other laboratory work. Statistical analysis was performed to compare and evaluate the learning effect measured in two groups of students: (1) electrical engineers and (2) natural scientists (i.e. medical doctors, biologists and chemists) undergoing the e-learning practical work in 2011-2014 academic years. Item analysis was performed to assess the difficulty of each item of the examination test. The results of our study show that the total score on the post examination test significantly improved and the item difficulty in both experimental groups decreased. The natural scientists reached the same level of knowledge (no statistical difference in total post-examination test score) on the post-course test take, as do electrical engineers, although the engineers started with statistically higher total pre-test examination score, as expected. The main objective of this study was to investigate whether the educational content the e-learning practical work presented to the students with different professional backgrounds enhanced their knowledge acquired via lectures during EBTT. We compared the learning effect assessed in two experimental groups undergoing the e-learning practical work: electrical engineers and natural scientists. The same level of knowledge on the post-course examination was reached in both groups. The results indicate that our e-learning platform supported by blended learning approach provides an effective learning tool for populations with mixed professional backgrounds and thus plays an important role in bridging the gap between scientific domains involved in electroporation-based technologies and treatments.

  8. Test Preparation: Your Role

    MedlinePlus

    ... transport the sample from home to the lab. Examples of some common laboratory tests that require advance preparation include: Glucose tolerance, fasting, and two-hour post-prandial blood glucose tests : fasting or eating meals ...

  9. HIV among African American Gay and Bisexual Men

    MedlinePlus

    ... Determination of Need Requests Pre-Exposure Prophylaxis (PrEP) Post-Exposure Prophylaxis (PEP) HIV Treatment as Prevention Condoms HIV in the Workplace HIV Testing Laboratory Tests Home Tests Testing in Nonclinical Settings CLIA Certificate ...

  10. Undergraduate Laboratory on a Turbulent Impinging Jet

    NASA Astrophysics Data System (ADS)

    Ivanosky, Arnaud; Brezzard, Etienne; van Poppel, Bret; Benson, Michael

    2017-11-01

    An undergraduate thermal sciences laboratory exercise that includes both experimental fluid mechanics and heat transfer measurements of an impinging jet is presented. The flow field is measured using magnetic resonance velocimetry (MRV) of a water flow, while IR thermography is used in the heat transfer testing. Flow Reynolds numbers for both the heat transfer and fluid mechanics tests range from 20,000-50,000 based on the jet diameter for a fully turbulent flow condition, with target surface temperatures in the heat transfer test reaching a maximum of approximately 50 Kelvin. The heat transfer target surface is subject to a measured uniform Joule heat flux, a well-defined boundary condition that allows comparison to existing correlations. The MRV generates a 3-component 3-dimensional data set, while the IR thermography provides a 2-dimensional heat transfer coefficient (or Nusselt number) map. These data sets can be post-processed and compared to existing correlations to verify data quality, and the sets can be juxtaposed to understand how flow features drive heat transfer. The laboratory setup, data acquisition, and analysis procedures are described for the laboratory experience, which can be incorporated as fluid mechanics, experimental methods, and heat transfer courses

  11. Virtual-reality-based educational laboratories in fiber optic engineering

    NASA Astrophysics Data System (ADS)

    Hayes, Dana; Turczynski, Craig; Rice, Jonny; Kozhevnikov, Michael

    2014-07-01

    Researchers and educators have observed great potential in virtual reality (VR) technology as an educational tool due to its ability to engage and spark interest in students, thus providing them with a deeper form of knowledge about a subject. The focus of this project is to develop an interactive VR educational module, Laser Diode Characteristics and Coupling to Fibers, to integrate into a fiber optics laboratory course. The developed module features a virtual laboratory populated with realistic models of optical devices in which students can set up and perform an optical experiment dealing with laser diode characteristics and fiber coupling. The module contains three increasingly complex levels for students to navigate through, with a short built-in quiz after each level to measure the student's understanding of the subject. Seventeen undergraduate students learned fiber coupling concepts using the designed computer simulation in a non-immersive desktop virtual environment (VE) condition. The analysis of students' responses on the updated pre- and post tests show statistically significant improvement of the scores for the post-test as compared to the pre-test. In addition, the students' survey responses suggest that they found the module very useful and engaging. The conducted study clearly demonstrated the feasibility of the proposed instructional technology for engineering education, where both the model of instruction and the enabling technology are equally important, in providing a better learning environment to improve students' conceptual understanding as compared to other instructional approaches.

  12. Capability of the Gas Analysis and Testing Laboratory at the NASA Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Broerman, Craig; Jimenez, Javier; Sweterlitsch, Jeff

    2012-01-01

    The Gas Analysis and Testing Laboratory is an integral part of the testing performed at the NASA Johnson Space Center. The Gas Analysis and Testing Laboratory is a high performance laboratory providing real time analytical instruments to support manned and unmanned testing. The lab utilizes precision gas chromatographs, gas analyzers and spectrophotometers to support the technology development programs within the NASA community. The Gas Analysis and Testing Laboratory works with a wide variety of customers and provides engineering support for user-specified applications in compressed gas, chemical analysis, general and research laboratory.

  13. Capability of the Gas Analysis and Testing Laboratory at the NASA Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Broerman, Craig; Jimenez, Javier; Sweterlitsch, Jeff

    2011-01-01

    The Gas Analysis and Testing Laboratory is an integral part of the testing performed at the NASA Johnson Space Center. The Gas Analysis and Testing Laboratory is a high performance laboratory providing real time analytical instruments to support manned and unmanned testing. The lab utilizes precision gas chromatographs, gas analyzers and spectrophotometers to support the technology development programs within the NASA community. The Gas Analysis and Testing Laboratory works with a wide variety of customers and provides engineering support for user-specified applications in compressed gas, chemical analysis, general and research laboratory

  14. Laboratory and 3-D distinct element analysis of the failure mechanism of a slope under external surcharge

    NASA Astrophysics Data System (ADS)

    Li, N.; Cheng, Y. M.

    2015-01-01

    Landslide is a major disaster resulting in considerable loss of human lives and property damages in hilly terrain in Hong Kong, China and many other countries. The factor of safety and the critical slip surface for slope stabilization are the main considerations for slope stability analysis in the past, while the detailed post-failure conditions of the slopes have not been considered in sufficient detail. There is however increasing interest in the consequences after the initiation of failure that includes the development and propagation of the failure surfaces, the amount of failed mass and runoff and the affected region. To assess the development of slope failure in more detail and to consider the potential danger of slopes after failure has initiated, the slope stability problem under external surcharge is analyzed by the distinct element method (DEM) and a laboratory model test in the present research. A more refined study about the development of failure, microcosmic failure mechanisms and the post-failure mechanisms of slopes will be carried out. The numerical modeling method and the various findings from the present work can provide an alternate method of analysis of slope failure, which can give additional information not available from the classical methods of analysis.

  15. Laboratory and 3-D-distinct element analysis of failure mechanism of slope under external surcharge

    NASA Astrophysics Data System (ADS)

    Li, N.; Cheng, Y. M.

    2014-09-01

    Landslide is a major disaster resulting in considerable loss of human lives and property damages in hilly terrain in Hong Kong, China and many other countries. The factor of safety and the critical slip surface for slope stabilization are the main considerations for slope stability analysis in the past, while the detailed post-failure conditions of the slopes have not been considered in sufficient details. There are however increasing interest on the consequences after the initiation of failure which includes the development and propagation of the failure surfaces, the amount of failed mass and runoff and the affected region. To assess the development of slope failure in more details and to consider the potential danger of slopes after failure has initiated, the slope stability problem under external surcharge is analyzed by the distinct element method (DEM) and laboratory model test in the present research. A more refined study about the development of failure, microcosmic failure mechanism and the post-failure mechanism of slope will be carried out. The numerical modeling method and the various findings from the present work can provide an alternate method of analysis of slope failure which can give additional information not available from the classical methods of analysis.

  16. Development, Analysis and Testing of the High Speed Research Flexible Semispan Model

    NASA Technical Reports Server (NTRS)

    Schuster, David M.; Spain, Charles V.; Turnock, David L.; Rausch, Russ D.; Hamouda, M-Nabil; Vogler, William A.; Stockwell, Alan E.

    1999-01-01

    This report presents the work performed by Lockheed Martin Engineering and Sciences (LMES) in support of the High Speed Research (HSR) Flexible Semispan Model (FSM) wind-tunnel test. The test was conducted in order to assess the aerodynamic and aeroelastic character of a flexible high speed civil transport wing. Data was acquired for the purpose of code validation and trend evaluation for this type of wing. The report describes a number of activities in preparing for and conducting the wind-tunnel test. These included coordination of the design and fabrication, development of analytical models, analysis/hardware correlation, performance of laboratory tests, monitoring of model safety issues, and wind-tunnel data acquisition and reduction. Descriptions and relevant evaluations associated with the pretest data are given in sections 1 through 6, followed by pre- and post-test flutter analysis in section 7, and the results of the aerodynamics/loads test in section 8. Finally, section 9 provides some recommendations based on lessons learned throughout the FSM program.

  17. 2000-hour cyclic endurance test of a laboratory model multipropellant resistojet

    NASA Technical Reports Server (NTRS)

    Morren, W. Earl; Sovey, James S.

    1987-01-01

    The technological readiness of a long-life multipropellant resistojet for space station auxiliary propulsion is demonstrated. A laboratory model resistojet made from grain-stabilized platinum served as a test bed to evaluate the design characteristics, fabrication methods, and operating strategies for an engineering model multipropellant resistojet developed under contract by the Rocketdyne Division of Rockwell International and Technion Incorporated. The laboratory model thruster was subjected to a 2000-hr, 2400-thermal-cycle endurance test using carbon dioxide propellant. Maximum thruster temperatures were approximately 1400 C. The post-test analyses of the laboratory model thruster included an investigation of component microstructures. Significant observations from the laboratory model thruster are discussed as they relate to the design of the engineering model thruster.

  18. A 2000-hour cyclic endurance test of a laboratory model multipropellant resistojet

    NASA Technical Reports Server (NTRS)

    Morren, W. Earl; Sovey, James S.

    1987-01-01

    The technological readiness of a long-life multipropellant resistojet for space station auxiliary propulsion is demonstrated. A laboratory model resistojet made from grain-stabilized platinum served as a test bed to evaluate the design characteristics, fabrication methods, and operating strategies for an engineering model multipropellant resistojet developed under contract by the Rocketdyne Division of Rockwell International and Technion Incorporated. The laboratory model thruster was subjected to a 2000-hr, 2400-thermal-cycle endurance test using carbon dioxide propellant. Maximum thruster temperatures were approximately 1400 C. The post-test analyses of the laboratory model thruster included an investigation of component microstructures. Significant observations from the laboratory model thruster are discussed as they relate to the design of the engineering model thruster.

  19. Cost Effectiveness of Adopted Quality Requirements in Hospital Laboratories

    PubMed Central

    HAMZA, Alneil; AHMED-ABAKUR, Eltayib; ABUGROUN, Elsir; BAKHIT, Siham; HOLI, Mohamed

    2013-01-01

    Background The present study was designed in quasi-experiment to assess adoption of the essential clauses of particular clinical laboratory quality management requirements based on international organization for standardization (ISO 15189) in hospital laboratories and to evaluate the cost effectiveness of compliance to ISO 15189. Methods: The quality management intervention based on ISO 15189 was conceded through three phases; pre – intervention phase, Intervention phase and Post-intervention phase. Results: In pre-intervention phase the compliance to ISO 15189 was 49% for study group vs. 47% for control group with P value 0.48, while the post intervention results displayed 54% vs. 79% for study group and control group respectively in compliance to ISO 15189 and statistically significant difference (P value 0.00) with effect size (Cohen’s d) of (0.00) in pre-intervention phase and (0.99) in post – intervention phase. The annual average cost per-test for the study group and control group was 1.80 ± 0.25 vs. 1.97 ± 0.39, respectively with P value 0.39 whereas the post-intervention results showed that the annual average total costs per-test for study group and control group was 1.57 ± 0.23 vs 2.08 ± 0.38, P value 0.019 respectively, with cost-effectiveness ratio of (0.88) in pre -intervention phase and (0.52) in post-intervention phase. Conclusion: The planned adoption of quality management requirements (QMS) in clinical laboratories had great effect to increase the compliance percent with quality management system requirement, raise the average total cost effectiveness, and improve the analytical process capability of the testing procedure. PMID:23967422

  20. Evaluation of Analytical Errors in a Clinical Chemistry Laboratory: A 3 Year Experience

    PubMed Central

    Sakyi, AS; Laing, EF; Ephraim, RK; Asibey, OF; Sadique, OK

    2015-01-01

    Background: Proficient laboratory service is the cornerstone of modern healthcare systems and has an impact on over 70% of medical decisions on admission, discharge, and medications. In recent years, there is an increasing awareness of the importance of errors in laboratory practice and their possible negative impact on patient outcomes. Aim: We retrospectively analyzed data spanning a period of 3 years on analytical errors observed in our laboratory. The data covered errors over the whole testing cycle including pre-, intra-, and post-analytical phases and discussed strategies pertinent to our settings to minimize their occurrence. Materials and Methods: We described the occurrence of pre-analytical, analytical and post-analytical errors observed at the Komfo Anokye Teaching Hospital clinical biochemistry laboratory during a 3-year period from January, 2010 to December, 2012. Data were analyzed with Graph Pad Prism 5(GraphPad Software Inc. CA USA). Results: A total of 589,510 tests was performed on 188,503 outpatients and hospitalized patients. The overall error rate for the 3 years was 4.7% (27,520/58,950). Pre-analytical, analytical and post-analytical errors contributed 3.7% (2210/58,950), 0.1% (108/58,950), and 0.9% (512/58,950), respectively. The number of tests reduced significantly over the 3-year period, but this did not correspond with a reduction in the overall error rate (P = 0.90) along with the years. Conclusion: Analytical errors are embedded within our total process setup especially pre-analytical and post-analytical phases. Strategic measures including quality assessment programs for staff involved in pre-analytical processes should be intensified. PMID:25745569

  1. Laboratory based instruction in Pakistan: Comparative evaluation of three laboratory instruction methods in biological science at higher secondary school level

    NASA Astrophysics Data System (ADS)

    Cheema, Tabinda Shahid

    This study of laboratory based instruction at higher secondary school level was an attempt to gain some insight into the effectiveness of three laboratory instruction methods: cooperative group instruction method, individualised instruction method and lecture demonstration method on biology achievement and retention. A Randomised subjects, Pre-test Post-test Comparative Methods Design was applied. Three groups of students from a year 11 class in Pakistan conducted experiments using the different laboratory instruction methods. Pre-tests, achievement tests after the experiments and retention tests one month later were administered. Results showed no significant difference between the groups on total achievement and retention, nor was there any significant difference on knowledge and comprehension test scores or skills performance. Future research investigating a similar problem is suggested.

  2. A study of the impact of collaborative learning on student learning of major concepts in a microbiology laboratory exercise

    NASA Astrophysics Data System (ADS)

    Baumgarten, Kristyne A.

    This study investigated the possible relationship between collaborative learning strategies and the learning of core concepts. This study examined the differences between two groups of nursing students enrolled in an introductory microbiology laboratory course. The control group consisted of students enrolled in sections taught in the traditional method. The experimental group consisted of those students enrolled in the sections using collaborative learning strategies. The groups were assessed on their degrees of learning core concepts using a pre-test/post-test method. Scores from the groups' laboratory reports were also analyzed. There was no difference in the two group's pre-test scores. The post-test scores of the experimental group averaged 11 points higher than the scores of the control group. The lab report scores of the experimental group averaged 15 points higher than those scores of the control group. The data generated from this study demonstrated that collaborative learning strategies can be used to increase students learning of core concepts in microbiology labs.

  3. Silicon Carbide Temperature Monitor Processing Improvements. Status Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unruh, Troy Casey; Daw, Joshua Earl; Ahamad Al Rashdan

    2016-01-29

    Silicon carbide (SiC) temperature monitors are used as temperature sensors in Advanced Test Reactor (ATR) irradiations at the Idaho National Laboratory (INL). Although thermocouples are typically used to provide real-time temperature indication in instrumented lead tests, other indicators, such as melt wires, are also often included in such tests as an independent technique of detecting peak temperatures incurred during irradiation. In addition, less expensive static capsule tests, which have no leads attached for real-time data transmission, often rely on melt wires as a post-irradiation technique for peak temperature indication. Melt wires are limited in that they can only detect whethermore » a single temperature is or is not exceeded. SiC monitors are advantageous because a single monitor can be used to detect for a range of temperatures that occurred during irradiation. As part of the process initiated to make SiC temperature monitors available at the ATR, post-irradiation evaluations of these monitors have been previously completed at the High Temperature Test Laboratory (HTTL). INL selected the resistance measurement approach for determining irradiation temperature from SiC temperature monitors because it is considered to be the most accurate measurement. The current process involves the repeated annealing of the SiC monitors at incrementally increasing temperature, with resistivity measurements made between annealing steps. The process is time consuming and requires the nearly constant attention of a trained staff member. In addition to the expensive and lengthy post analysis required, the current process adds many potential sources of error in the measurement, as the sensor must be repeatedly moved from furnace to test fixture. This time-consuming post irradiation analysis is a significant portion of the total cost of using these otherwise inexpensive sensors. An additional consideration of this research is that, if the SiC post processing can be automated, it could be performed in an MFC hot cell, further reducing the time and expense of lengthy decontaminations prior to processing. Sections of this report provide a general description of resistivity techniques currently used to infer peak irradiation temperature from silicon carbide temperature monitors along with some representative data, the proposed concepts to improve the process of analyzing irradiated SiC temperature monitors, the completed efforts to prove the proposed concepts, and future activities. The efforts detailed here succeeded in designing and developing a real-time automated SiC resistivity measurement system, and performed two initial test runs. Activities carried out include the assembly and integration of the system hardware; the design and development of a preliminary monitor fixture; the design of a technique to automate the data analysis and processing; the development of the communication, coordination, and user software; and the execution and troubleshooting of test run experiments using the box furnace. Although the automation system performed as required, the designed fixture did not succeed in establishing the needed electrical contacts with the SiC monitor.« less

  4. The efficacy of World Wide Web-mediated microcomputer-based laboratory activities in the high school physics classroom

    NASA Astrophysics Data System (ADS)

    Slykhuis, David A.

    This research project examined the efficacy of an online microcomputer-based laboratory based (MBL) physics unit. One hundred and fifty physics students from five high schools in North Carolina were divided into online and classroom groups. The classroom group completed the MBL unit in small groups with assistance from their teachers. The online groups completed the MBL unit in small groups using a website designed for this project for guidance. Pre- and post-unit content specific tests and surveys were given. Statistical analysis of the content tests showed significant development of conceptual understanding by the online group over the course of the unit. There was not a significant difference between the classroom and online group with relation to the amount of conceptual understanding developed. Correlations with post-test achievement showed that pre-test scores and math background were the most significant correlates with success. Computer related variables, such as computer comfort and online access, were only mildly correlated with the online group. Students' views about the nature of physics were not well developed prior to the unit and did not significantly change over the course of the unit. Examination of the students' physics conceptions after instruction revealed common alternative conceptions such as confusing position and velocity variables and incorrect interpretations of graphical features such as slope.

  5. CRREL (Cold Regions Research and Engineering Laboratory) Technical Publications. Supplement, October 1986-September 1988

    DTIC Science & Technology

    1988-09-01

    1000. Extensive post -test optical analysis allowed Antenna polarization and height, and sigaal stacking estimation of the size distribution and number of...to 10 C higher under natural activated sludge. A design example is presented for conditions than in the wind tunnel studies. Results each case. All...typically limitations of the methcd are presented, examples are columnar type crystal structure. The remaining 2i% shown, and notes on user instructions are

  6. Position Statement Executive Summary: Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus

    PubMed Central

    Arnold, Mark; Bakris, George L.; Bruns, David E.; Horvath, Andrea Rita; Kirkman, M. Sue; Lernmark, Ake; Metzger, Boyd E.; Nathan, David M.

    2011-01-01

    BACKGROUND Multiple laboratory tests are used in the diagnosis and management of patients with diabetes mellitus. The quality of the scientific evidence supporting the use of these assays varies substantially. APPROACH An expert committee compiled evidence-based recommendations for the use of laboratory analysis in patients with diabetes. A new system was developed to grade the overall quality of the evidence and the strength of the recommendations. A draft of the guidelines was posted on the Internet, and the document was modified in response to comments. The guidelines were reviewed by the joint Evidence-Based Laboratory Medicine Committee of the AACC and the National Academy of Clinical Biochemistry and were accepted after revisions by the Professional Practice Committee and subsequent approval by the Executive Committee of the American Diabetes Association. CONTENT In addition to the long-standing criteria based on measurement of venous plasma glucose, diabetes can be diagnosed by demonstrating increased hemoglobin A1c (HbA1c) concentrations in the blood. Monitoring of glycemic control is performed by the patients measuring their own plasma or blood glucose with meters and by laboratory analysis of HbA1c. The potential roles of noninvasive glucose monitoring, genetic testing, and measurement of autoantibodies, urine albumin, insulin, proinsulin, C-peptide, and other analytes are addressed. SUMMARY The guidelines provide specific recommendations based on published data or derived from expert consensus. Several analytes are found to have minimal clinical value at the present time, and measurement of them is not recommended. PMID:21617111

  7. Position statement executive summary: guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus.

    PubMed

    Sacks, David B; Arnold, Mark; Bakris, George L; Bruns, David E; Horvath, Andrea Rita; Kirkman, M Sue; Lernmark, Ake; Metzger, Boyd E; Nathan, David M

    2011-06-01

    Multiple laboratory tests are used in the diagnosis and management of patients with diabetes mellitus. The quality of the scientific evidence supporting the use of these assays varies substantially. An expert committee compiled evidence-based recommendations for the use of laboratory analysis in patients with diabetes. A new system was developed to grade the overall quality of the evidence and the strength of the recommendations. A draft of the guidelines was posted on the Internet, and the document was modified in response to comments. The guidelines were reviewed by the joint Evidence-Based Laboratory Medicine Committee of the AACC and the National Academy of Clinical Biochemistry and were accepted after revisions by the Professional Practice Committee and subsequent approval by the Executive Committee of the American Diabetes Association. In addition to the long-standing criteria based on measurement of venous plasma glucose, diabetes can be diagnosed by demonstrating increased hemoglobin A(1c) (HbA(1c)) concentrations in the blood. Monitoring of glycemic control is performed by the patients measuring their own plasma or blood glucose with meters and by laboratory analysis of HbA(1c). The potential roles of noninvasive glucose monitoring, genetic testing, and measurement of autoantibodies, urine albumin, insulin, proinsulin, C-peptide, and other analytes are addressed. The guidelines provide specific recommendations based on published data or derived from expert consensus. Several analytes are found to have minimal clinical value at the present time, and measurement of them is not recommended.

  8. [Quality Management and Quality Specifications of Laboratory Tests in Clinical Studies--Challenges in Pre-Analytical Processes in Clinical Laboratories].

    PubMed

    Ishibashi, Midori

    2015-01-01

    The cost, speed, and quality are the three important factors recently indicated by the Ministry of Health, Labour and Welfare (MHLW) for the purpose of accelerating clinical studies. Based on this background, the importance of laboratory tests is increasing, especially in the evaluation of clinical study participants' entry and safety, and drug efficacy. To assure the quality of laboratory tests, providing high-quality laboratory tests is mandatory. For providing adequate quality assurance in laboratory tests, quality control in the three fields of pre-analytical, analytical, and post-analytical processes is extremely important. There are, however, no detailed written requirements concerning specimen collection, handling, preparation, storage, and shipping. Most laboratory tests for clinical studies are performed onsite in a local laboratory; however, a part of laboratory tests is done in offsite central laboratories after specimen shipping. As factors affecting laboratory tests, individual and inter-individual variations are well-known. Besides these factors, standardizing the factors of specimen collection, handling, preparation, storage, and shipping, may improve and maintain the high quality of clinical studies in general. Furthermore, the analytical method, units, and reference interval are also important factors. It is concluded that, to overcome the problems derived from pre-analytical processes, it is necessary to standardize specimen handling in a broad sense.

  9. Centralization of a regional clinical microbiology service: The Calgary experience

    PubMed Central

    Church, Deirdre L; Hall, Paula

    1999-01-01

    Diagnostic laboratory services in Alberta have been dramatically restructured over the past five years. In 1994, Alberta Health embarked on an aggressive laboratory restructuring that cut back approximately 30% of the overall monies previously paid to the laboratory service sector in Calgary. A unique service delivery model consolidated all institutional and community-based diagnostic testing in a company called Calgary Laboratory Services (CLS) in late 1996. CLS was formed by a public/private partnership between the Calgary Regional Health Care Authority (CRHA) and MDS-Kasper Laboratories. By virtue of its customer service base and scope of testing, CLS provides comprehensive regional laboratory services to the entire populace. Regional microbiology services within CLS have been successfully consolidated over the past three years into a centralized high volume laboratory (HVL). Because the HVL is not located in a hospital, rapid response laboratories (RRLs) are operated at each acute care site. Although the initial principle behind the proposed test menus for the RRLs was that only procedures requiring a clinical turnaround time of more than 2 h stay on-site, many other principles had to be used to develop and implement an efficient and clinically relevant RRL model for microbiology. From these guiding principles, a detailed assessment of the needs of each institution and extensive networking with user groups, the functions of the microbiology RRLs were established and a detailed implementation plan drawn up. The experience at CLS with regards to restructuring a regional microbiology service is described herein. A post-hoc analysis provides the pros and cons of directing and operating a regionalized microbiology service. PMID:22346397

  10. Evaluation of the Impact of Fatty Acid Methyl Ester (FAME) Contamination on the Thermal Stability of Jet A

    DTIC Science & Technology

    2013-11-01

    contamination in Jet A from 5 ppm to 100 ppm. Testing was performed by the U.S. Air Force at the Air Force Research Laboratory, Fuels and Energy...50 5.9.4 Post -Program EDTST Mode Additional Testing .............................................................. 50 6.0...124 Appendix H – Additional Post -Program Testing to Evaluate Impact of FAME on Typical Jet A of Reasonable Thermal Stability

  11. Simple non-laboratory- and laboratory-based risk assessment algorithms and nomogram for detecting undiagnosed diabetes mellitus.

    PubMed

    Wong, Carlos K H; Siu, Shing-Chung; Wan, Eric Y F; Jiao, Fang-Fang; Yu, Esther Y T; Fung, Colman S C; Wong, Ka-Wai; Leung, Angela Y M; Lam, Cindy L K

    2016-05-01

    The aim of the present study was to develop a simple nomogram that can be used to predict the risk of diabetes mellitus (DM) in the asymptomatic non-diabetic subjects based on non-laboratory- and laboratory-based risk algorithms. Anthropometric data, plasma fasting glucose, full lipid profile, exercise habits, and family history of DM were collected from Chinese non-diabetic subjects aged 18-70 years. Logistic regression analysis was performed on a random sample of 2518 subjects to construct non-laboratory- and laboratory-based risk assessment algorithms for detection of undiagnosed DM; both algorithms were validated on data of the remaining sample (n = 839). The Hosmer-Lemeshow test and area under the receiver operating characteristic (ROC) curve (AUC) were used to assess the calibration and discrimination of the DM risk algorithms. Of 3357 subjects recruited, 271 (8.1%) had undiagnosed DM defined by fasting glucose ≥7.0 mmol/L or 2-h post-load plasma glucose ≥11.1 mmol/L after an oral glucose tolerance test. The non-laboratory-based risk algorithm, with scores ranging from 0 to 33, included age, body mass index, family history of DM, regular exercise, and uncontrolled blood pressure; the laboratory-based risk algorithm, with scores ranging from 0 to 37, added triglyceride level to the risk factors. Both algorithms demonstrated acceptable calibration (Hosmer-Lemeshow test: P = 0.229 and P = 0.483) and discrimination (AUC 0.709 and 0.711) for detection of undiagnosed DM. A simple-to-use nomogram for detecting undiagnosed DM has been developed using validated non-laboratory-based and laboratory-based risk algorithms. © 2015 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

  12. AGR-1 Post Irradiation Examination Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demkowicz, Paul Andrew

    The post-irradiation examination (PIE) of the Advanced Gas Reactor (AGR)-1 experiment was a multi-year, collaborative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to study the performance of UCO (uranium carbide, uranium oxide) tristructural isotropic (TRISO) coated particle fuel fabricated in the U.S. and irradiated at the Advanced Test Reactor at INL to a peak burnup of 19.6% fissions per initial metal atom. This work involved a broad array of experiments and analyses to evaluate the level of fission product retention by the fuel particles and compacts (both during irradiation and during post-irradiation heating tests tomore » simulate reactor accident conditions), investigate the kernel and coating layer morphology evolution and the causes of coating failure, and explore the migration of fission products through the coating layers. The results have generally confirmed the excellent performance of the AGR-1 fuel, first indicated during the irradiation by the observation of zero TRISO coated particle failures out of 298,000 particles in the experiment. Overall release of fission products was determined by PIE to have been relatively low during the irradiation. A significant finding was the extremely low levels of cesium released through intact coatings. This was true both during the irradiation and during post-irradiation heating tests to temperatures as high as 1800°C. Post-irradiation safety test fuel performance was generally excellent. Silver release from the particles and compacts during irradiation was often very high. Extensive microanalysis of fuel particles was performed after irradiation and after high-temperature safety testing. The results of particle microanalysis indicate that the UCO fuel is effective at controlling the oxygen partial pressure within the particle and limiting kernel migration. Post-irradiation examination has provided the final body of data that speaks to the quality of the AGR-1 fuel, building on the as-fabricated fuel characterization and irradiation data. In addition to the extensive volume of results generated, the work also resulted in a number of novel analysis techniques and lessons learned that are being applied to the examination of fuel from subsequent TRISO fuel irradiations. This report provides a summary of the results obtained as part of the AGR-1 PIE campaign over its approximately 5-year duration.« less

  13. Uninvolved versus target muscle contraction during contract: relax proprioceptive neuromuscular facilitation stretching.

    PubMed

    Azevedo, Daniel Camara; Melo, Raphael Marques; Alves Corrêa, Ricardo Vidal; Chalmers, Gordon

    2011-08-01

    The purpose of this study was to compare the acute effect of the contract-relax (CR) stretching technique on knee active range of motion (ROM) using target muscle contraction or an uninvolved muscle contraction. pre-test post-test control experimental design. Clinical research laboratory. Sixty healthy men were randomly assigned to one of three groups. The Contract-Relax group (CR) performed a traditional hamstring CR stretch, the Modified Contract-Relax group (MCR) performed hamstring CR stretching using contraction of an uninvolved muscle distant from the target muscle, and the Control group (CG) did not stretch. Active knee extension test was performed before and after the stretching procedure. Two-way between-within analysis of variance (ANOVA) results showed a significant interaction between group and pre-test to post-test (p < 0.001). Post-hoc examination of individual groups showed no significant change in ROM for the CG (0.8°, p = 0.084), and a significant moderate increase in ROM for both the CR (7.0°, p < 0.001) and MCR (7.0°, p < 0.001) groups. ROM gain following a CR PNF procedure is the same whether the target stretching muscle is contracted, or an uninvolved muscle is contracted. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Consequences of common data analysis inaccuracies in CNS trauma injury basic research.

    PubMed

    Burke, Darlene A; Whittemore, Scott R; Magnuson, David S K

    2013-05-15

    The development of successful treatments for humans after traumatic brain or spinal cord injuries (TBI and SCI, respectively) requires animal research. This effort can be hampered when promising experimental results cannot be replicated because of incorrect data analysis procedures. To identify and hopefully avoid these errors in future studies, the articles in seven journals with the highest number of basic science central nervous system TBI and SCI animal research studies published in 2010 (N=125 articles) were reviewed for their data analysis procedures. After identifying the most common statistical errors, the implications of those findings were demonstrated by reanalyzing previously published data from our laboratories using the identified inappropriate statistical procedures, then comparing the two sets of results. Overall, 70% of the articles contained at least one type of inappropriate statistical procedure. The highest percentage involved incorrect post hoc t-tests (56.4%), followed by inappropriate parametric statistics (analysis of variance and t-test; 37.6%). Repeated Measures analysis was inappropriately missing in 52.0% of all articles and, among those with behavioral assessments, 58% were analyzed incorrectly. Reanalysis of our published data using the most common inappropriate statistical procedures resulted in a 14.1% average increase in significant effects compared to the original results. Specifically, an increase of 15.5% occurred with Independent t-tests and 11.1% after incorrect post hoc t-tests. Utilizing proper statistical procedures can allow more-definitive conclusions, facilitate replicability of research results, and enable more accurate translation of those results to the clinic.

  15. Development of fire test methods for airplane interior materials

    NASA Technical Reports Server (NTRS)

    Tustin, E. A.

    1978-01-01

    Fire tests were conducted in a 737 airplane fuselage at NASA-JSC to characterize jet fuel fires in open steel pans (simulating post-crash fire sources and a ruptured airplane fuselage) and to characterize fires in some common combustibles (simulating in-flight fire sources). Design post-crash and in-flight fire source selections were based on these data. Large panels of airplane interior materials were exposed to closely-controlled large scale heating simulations of the two design fire sources in a Boeing fire test facility utilizing a surplused 707 fuselage section. Small samples of the same airplane materials were tested by several laboratory fire test methods. Large scale and laboratory scale data were examined for correlative factors. Published data for dangerous hazard levels in a fire environment were used as the basis for developing a method to select the most desirable material where trade-offs in heat, smoke and gaseous toxicant evolution must be considered.

  16. Managing the Pre- and Post-analytical Phases of the Total Testing Process

    PubMed Central

    2012-01-01

    For many years, the clinical laboratory's focus on analytical quality has resulted in an error rate of 4-5 sigma, which surpasses most other areas in healthcare. However, greater appreciation of the prevalence of errors in the pre- and post-analytical phases and their potential for patient harm has led to increasing requirements for laboratories to take greater responsibility for activities outside their immediate control. Accreditation bodies such as the Joint Commission International (JCI) and the College of American Pathologists (CAP) now require clear and effective procedures for patient/sample identification and communication of critical results. There are a variety of free on-line resources available to aid in managing the extra-analytical phase and the recent publication of quality indicators and proposed performance levels by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) working group on laboratory errors and patient safety provides particularly useful benchmarking data. Managing the extra-laboratory phase of the total testing cycle is the next challenge for laboratory medicine. By building on its existing quality management expertise, quantitative scientific background and familiarity with information technology, the clinical laboratory is well suited to play a greater role in reducing errors and improving patient safety outside the confines of the laboratory. PMID:22259773

  17. To Compare the Effects of Computer Based Learning and the Laboratory Based Learning on Students' Achievement Regarding Electric Circuits

    ERIC Educational Resources Information Center

    Bayrak, Bekir; Kanli, Uygar; Kandil Ingeç, Sebnem

    2007-01-01

    In this study, the research problem was: "Is the computer based physics instruction as effective as laboratory intensive physics instruction with regards to academic success on electric circuits 9th grade students?" For this research of experimental quality the design of pre-test and post-test are applied with an experiment and a control…

  18. A computer-managed undergraduate physics laboratory

    NASA Astrophysics Data System (ADS)

    Kalman, C. S.

    1987-01-01

    Seventeen one-semester undergraduate laboratory courses are managed by a microcomputer system at Concordia University. Students may perform experiments at any time during operating hours. The computer administers pre- and post-tests. Considerable savings in manpower costs is achieved. The system also provides many pedagogical advantages.

  19. Gene Polymorphism Studies in a Teaching Laboratory

    ERIC Educational Resources Information Center

    Shultz, Jeffry

    2009-01-01

    I present a laboratory procedure for illustrating transcription, post-transcriptional modification, gene conservation, and comparative genetics for use in undergraduate biology education. Students are individually assigned genes in a targeted biochemical pathway, for which they design and test polymerase chain reaction (PCR) primers. In this…

  20. Clinical Chemistry Laboratory Automation in the 21st Century - Amat Victoria curam (Victory loves careful preparation)

    PubMed Central

    Armbruster, David A; Overcash, David R; Reyes, Jaime

    2014-01-01

    The era of automation arrived with the introduction of the AutoAnalyzer using continuous flow analysis and the Robot Chemist that automated the traditional manual analytical steps. Successive generations of stand-alone analysers increased analytical speed, offered the ability to test high volumes of patient specimens, and provided large assay menus. A dichotomy developed, with a group of analysers devoted to performing routine clinical chemistry tests and another group dedicated to performing immunoassays using a variety of methodologies. Development of integrated systems greatly improved the analytical phase of clinical laboratory testing and further automation was developed for pre-analytical procedures, such as sample identification, sorting, and centrifugation, and post-analytical procedures, such as specimen storage and archiving. All phases of testing were ultimately combined in total laboratory automation (TLA) through which all modules involved are physically linked by some kind of track system, moving samples through the process from beginning-to-end. A newer and very powerful, analytical methodology is liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS). LC-MS/MS has been automated but a future automation challenge will be to incorporate LC-MS/MS into TLA configurations. Another important facet of automation is informatics, including middleware, which interfaces the analyser software to a laboratory information systems (LIS) and/or hospital information systems (HIS). This software includes control of the overall operation of a TLA configuration and combines analytical results with patient demographic information to provide additional clinically useful information. This review describes automation relevant to clinical chemistry, but it must be recognised that automation applies to other specialties in the laboratory, e.g. haematology, urinalysis, microbiology. It is a given that automation will continue to evolve in the clinical laboratory, limited only by the imagination and ingenuity of laboratory scientists. PMID:25336760

  1. Clinical Chemistry Laboratory Automation in the 21st Century - Amat Victoria curam (Victory loves careful preparation).

    PubMed

    Armbruster, David A; Overcash, David R; Reyes, Jaime

    2014-08-01

    The era of automation arrived with the introduction of the AutoAnalyzer using continuous flow analysis and the Robot Chemist that automated the traditional manual analytical steps. Successive generations of stand-alone analysers increased analytical speed, offered the ability to test high volumes of patient specimens, and provided large assay menus. A dichotomy developed, with a group of analysers devoted to performing routine clinical chemistry tests and another group dedicated to performing immunoassays using a variety of methodologies. Development of integrated systems greatly improved the analytical phase of clinical laboratory testing and further automation was developed for pre-analytical procedures, such as sample identification, sorting, and centrifugation, and post-analytical procedures, such as specimen storage and archiving. All phases of testing were ultimately combined in total laboratory automation (TLA) through which all modules involved are physically linked by some kind of track system, moving samples through the process from beginning-to-end. A newer and very powerful, analytical methodology is liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS). LC-MS/MS has been automated but a future automation challenge will be to incorporate LC-MS/MS into TLA configurations. Another important facet of automation is informatics, including middleware, which interfaces the analyser software to a laboratory information systems (LIS) and/or hospital information systems (HIS). This software includes control of the overall operation of a TLA configuration and combines analytical results with patient demographic information to provide additional clinically useful information. This review describes automation relevant to clinical chemistry, but it must be recognised that automation applies to other specialties in the laboratory, e.g. haematology, urinalysis, microbiology. It is a given that automation will continue to evolve in the clinical laboratory, limited only by the imagination and ingenuity of laboratory scientists.

  2. An analysis of high school students' perceptions and academic performance in laboratory experiences

    NASA Astrophysics Data System (ADS)

    Mirchin, Robert Douglas

    This research study is an investigation of student-laboratory (i.e., lab) learning based on students' perceptions of experiences using questionnaire data and evidence of their science-laboratory performance based on paper-and-pencil assessments using Maryland-mandated criteria, Montgomery County Public Schools (MCPS) criteria, and published laboratory questions. A 20-item questionnaire consisting of 18 Likert-scale items and 2 open-ended items that addressed what students liked most and least about lab was administered to students before labs were observed. A pre-test and post-test assessing laboratory achievement were administered before and after the laboratory experiences. The three labs observed were: soda distillation, stoichiometry, and separation of a mixture. Five significant results or correlations were found. For soda distillation, there were two positive correlations. Student preference for analyzing data was positively correlated with achievement on the data analysis dimension of the lab rubric. A student preference for using numbers and graphs to analyze data was positively correlated with achievement on the analysis dimension of the lab rubric. For the separating a mixture lab data the following pairs of correlations were significant. Student preference for doing chemistry labs where numbers and graphs were used to analyze data had a positive correlation with writing a correctly worded hypothesis. Student responses that lab experiences help them learn science positively correlated with achievement on the data dimension of the lab rubric. The only negative correlation found related to the first result where students' preference for computers was inversely correlated to their performance on analyzing data on their lab report. Other findings included the following: students like actual experimental work most and the write-up and analysis of a lab the least. It is recommended that lab science instruction be inquiry-based, hands-on, and that students be tested for lab content acquisition. The final conclusion of the study is that students expressed a preference for working in groups and working with materials and equipment as opposed to individual, non-group work and analyzing data.

  3. 49 CFR Appendix B to Part 40 - DOT Drug Testing Semi-Annual Laboratory Report to Employers

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... Specimen Results Reported (total number) By Test Reason (a) Pre-employment (number) (b) Post-Accident...) Follow-up (number) (g) Type of Test Not Noted on CCF (number) 2. Specimens Reported (a) Negative (number...

  4. 49 CFR Appendix B to Part 40 - DOT Drug Testing Semi-Annual Laboratory Report to Employers

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... Specimen Results Reported (total number) By Test Reason (a) Pre-employment (number) (b) Post-Accident...) Follow-up (number) (g) Type of Test Not Noted on CCF (number) 2. Specimens Reported (a) Negative (number...

  5. 49 CFR Appendix B to Part 40 - DOT Drug Testing Semi-Annual Laboratory Report to Employers

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... Specimen Results Reported (total number) By Test Reason (a) Pre-employment (number) (b) Post-Accident...) Follow-up (number) (g) Type of Test Not Noted on CCF (number) 2. Specimens Reported (a) Negative (number...

  6. 49 CFR Appendix B to Part 40 - DOT Drug Testing Semi-Annual Laboratory Report to Employers

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... Specimen Results Reported (total number) By Test Reason (a) Pre-employment (number) (b) Post-Accident...) Follow-up (number) (g) Type of Test Not Noted on CCF (number) 2. Specimens Reported (a) Negative (number...

  7. 49 CFR Appendix B to Part 40 - DOT Drug Testing Semi-Annual Laboratory Report to Employers

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... Specimen Results Reported (total number) By Test Reason (a) Pre-employment (number) (b) Post-Accident...) Follow-up (number) (g) Type of Test Not Noted on CCF (number) 2. Specimens Reported (a) Negative (number...

  8. AGC-2 Specimen Post Irradiation Data Package Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Windes, William Enoch; Swank, W. David; Rohrbaugh, David T.

    This report documents results of the post-irradiation examination material property testing of the creep, control, and piggyback specimens from the irradiation creep capsule Advanced Graphite Creep (AGC)-2 are reported. This is the second of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades. The AGC-2 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 600°C and to a peak dose of 5 dpa (displacements per atom). One-half of the creep specimens weremore » subjected to mechanical stresses (an applied stress of either 13.8, 17.2, or 20.7 MPa) to induce irradiation creep. All post-irradiation testing and measurement results are reported with the exception of the irradiation mechanical strength testing, which is the last destructive testing stage of the irradiation testing program. Material property tests were conducted on specimens from 15 nuclear graphite grades using a similar loading configuration as the first AGC capsule (AGC-1) to provide easy comparison between the two capsules. However, AGC-2 contained an increased number of specimens (i.e., 487 total specimens irradiated) and replaced specimens of the minor grade 2020 with the newer grade 2114. The data reported include specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and volume data necessary to derive density, elastic constants (Young’s modulus, shear modulus, and Poisson’s ratio) from ultrasonic time-of-flight velocity measurements, Young’s modulus from the fundamental frequency of vibration, electrical resistivity, and thermal diffusivity and thermal expansion data from 100–500°C. No data outliers were determined after all measurements were completed. A brief statistical analysis was performed on the irradiated data and a limited comparison between pre- and post-irradiation properties is presented. A more complete evaluation of trends in the material property changes, as well as irradiation-induced creep due to irradiation, temperature, and applied load on specimens will be discussed in later AGC-2 post-irradiation examination analysis reports.« less

  9. Evaluation of New Technologies for Protection of Military Personnel from Filth and Biting Flies

    DTIC Science & Technology

    2007-10-01

    Page 1. INTRODUCTION 3 2. RESEACH ACCOMPLISHMENTS FOR YEAR 3: 5 A. Students 5 B. Most Recent Research Results 6 I. Wind Tunnel for Testing ...were released per arena, and morbidity (knockdown) was recorded at 2-5 h post -treatment and mortality was recorded at 24, 48, and 72 h. Field Test ...Keuls test ) 42 Figure 3-1. Laboratory and field experimental design elements. A). Laboratory arena constructed of PVC pipe. Cords

  10. Laboratory safety and the WHO World Alliance for Patient Safety.

    PubMed

    McCay, Layla; Lemer, Claire; Wu, Albert W

    2009-06-01

    Laboratory medicine has been a pioneer in the field of patient safety; indeed, the College of American Pathology first called attention to the issue in 1946. Delivering reliable laboratory results has long been considered a priority, as the data produced in laboratory medicine have the potential to critically influence individual patients' diagnosis and management. Until recently, most attention on laboratory safety has focused on the analytic stage of laboratory medicine. Addressing this stage has led to significant and impressive improvements in the areas over which laboratories have direct control. However, recent data demonstrate that pre- and post-analytical phases are at least as vulnerable to errors; to further improve patient safety in laboratory medicine, attention must now be focused on the pre- and post-analytic phases, and the concept of patient safety as a multi-disciplinary, multi-stage and multi-system concept better understood. The World Alliance for Patient Safety (WAPS) supports improvement of patient safety globally and provides a potential framework for considering the total testing process.

  11. Simulation of a mycological KOH preparation--e-learning as a practical dermatologic exercise in an undergraduate medical curriculum.

    PubMed

    Bernhardt, Johannes; Hye, Florian; Thallinger, Sigrid; Bauer, Pamela; Ginter, Gabriele; Smolle, Josef

    2009-07-01

    Mycological KOH preparation is one of the most popular practical laboratory skills in dermatology. The study addresses the question whether an interactive simulation program enhances knowledge of students about this procedure. 166 students, 107 female and 59 male, participated. We separated our study in three phases: pretest, completing the simulation three times and post-test. In the pre- and post-test we recorded the number of correct steps of the mycological KOH preparation listed by the students. The full text feedback was explored by content analysis. In the pre-test the students listed an average of 3.1 +/- 2.2 correct steps, compared to 8.8 +/- 1.2 correct steps after completing the simulation (p < 0.001). Furthermore, the improvement was significant for each individual step. There were no significant differences between male and female students. In content analysis of the feedback, positive statements prevailed with 78.3%, compared to only 1.8% critical items. Our study shows that an interactive computer simulation program of mycological KOH preparation results in a significant learning effectiveness as far as recall of the correct procedural steps is concerned. Furthermore, subjective acceptance by students is high.

  12. Special report on the data collection programs for the ground based nitrogen washout experiment. Volume 1: User's guide

    NASA Technical Reports Server (NTRS)

    Bueker, P. A.

    1982-01-01

    The Nitrogen Washout System measures nitrogen elimination on a breath basis from the body tissues of a subject breathing pure oxygen. The system serves as a prototype for a Space Shuttle Life Sciences experiment and in the Environmental Physiology Laboratory. Typically, a subject washes out body nitrogen for three hours while breathing oxygen from a mask enclosed in a positive-pressure oxygen tent. A nitrogen washout requires one test operator and the test subject. A DEC LSI-11/02 computer is used to (1) control and calibrate the mass spectrometer and Skylab spirometer, (2) gather and store experimental data and (3) provide limited real time analysis and more extensive post-experiment analysis. Five programs are used to gather and store the experimental data and perform all the real time control and analysis.

  13. Evaluation of active ingredients and larvicidal activity of clove and cinnamon essential oils against Anopheles gambiae (sensu lato).

    PubMed

    Thomas, Adelina; Mazigo, Humphrey D; Manjurano, Alphaxard; Morona, Domenica; Kweka, Eliningaya J

    2017-09-06

    Mosquitoes are well-known vectors of many diseases including malaria and lymphatic filariasis. Uses of synthetic insecticides are associated with high toxicity, resistance, environmental pollution and limited alternative, effective synthetic insecticides. This study was undertaken to evaluate the larvicidal efficacy of clove and cinnamon essential oils against laboratory Anopheles gambiae (sensu stricto) and wild An. arabiensis larvae. The standard WHO guideline for larvicides evaluation was used, and the GC-MS machine was used for active compounds percentage composition analysis and structures identification. Probit regression analysis was used for LC 50 and LC 95 calculations while a t-test was used to test for significant differences between laboratory-reared and wild larvae populations in each concentration of plant extract. Mortality effect of clove and cinnamon essential oils against wild and laboratory-reared larvae had variations indicated by their LC 50 and LC 95 values. The mortality at different concentrations of cinnamon and clove post-exposure for wild and laboratory-reared larvae were dosage-dependent and were higher for cinnamon than for clove essential oils. The mortality effect following exposure to a blend of the two essential oils was higher for blends containing a greater proportion of cinnamon oil. In the chemical analysis of the active ingredients of cinnamon essential oil, the main chemical content was Eugenol, and the rarest was β-Linalool while for clove essential oil, the main chemical content was Eugenol and the rarest was Bicyclo. The essential oils showed a larvicidal effect which was concentration-dependent for both laboratory and wild collected larvae. The active ingredient compositions triggered different responses in mortality. Further research in small-scale should be conducted with concentrated extracted compounds.

  14. Epstein-Barr virus: general factors, virus-related diseases and measurement of viral load after transplant

    PubMed Central

    Gequelin, Luciana Cristina Fagundes; Riediger, Irina N.; Nakatani, Sueli M.; Biondo, Alexander W.; Bonfim, Carmem M.

    2011-01-01

    The Epstein-Barr virus is responsible for infectious mononucleosis syndrome and is also closely associated to several types of cancer. The main complication involving Epstein-Barr virus infection, both in recipients of hematopoietic stem cells and solid organs, is post-transplant lymphoproliferative disease. The importance of this disease has increased interest in the development of laboratory tools to improve post-transplant monitoring and to detect the disease before clinical evolution. Viral load analysis for Epstein-Barr virus through real-time polymerase chain reaction is, at present, the best tool to measure viral load. However, there is not a consensus on which sample type is the best for the test and what is its predictive value for therapeutic interventions. PMID:23049344

  15. System reliability of randomly vibrating structures: Computational modeling and laboratory testing

    NASA Astrophysics Data System (ADS)

    Sundar, V. S.; Ammanagi, S.; Manohar, C. S.

    2015-09-01

    The problem of determination of system reliability of randomly vibrating structures arises in many application areas of engineering. We discuss in this paper approaches based on Monte Carlo simulations and laboratory testing to tackle problems of time variant system reliability estimation. The strategy we adopt is based on the application of Girsanov's transformation to the governing stochastic differential equations which enables estimation of probability of failure with significantly reduced number of samples than what is needed in a direct simulation study. Notably, we show that the ideas from Girsanov's transformation based Monte Carlo simulations can be extended to conduct laboratory testing to assess system reliability of engineering structures with reduced number of samples and hence with reduced testing times. Illustrative examples include computational studies on a 10-degree of freedom nonlinear system model and laboratory/computational investigations on road load response of an automotive system tested on a four-post test rig.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gesta, E.; Intelligent Insect Control, 118 Chemin des Alouettes, Castelnau-le-Lez, 34170; Skovmand, O., E-mail: osk@insectcontrol.net

    The purpose of this study is to understand the influence of the yarn processing on the migration of additives molecules, especially insecticide, within polyethylene (PE) yarns. Yarns were manufactured in the laboratory focusing on three key-steps (spinning, post-stretching and heat-setting). Influence of each step on yarn properties was investigated using tensile tests, differential scanning calorimetry and wide-angle X-ray diffraction. The post-stretching step was proved to be critical in defining yarn mechanical and structural properties. Although a first orientation of polyethylene crystals was induced during spinning, the optimal orientation was only reached by post-stretching. The results also showed that the heat-settingmore » did not significantly change these properties. The presence of additives crystals at the yarn surface was evidenced by scanning-electron microscopy. These studies performed at each yarn production step allowed a detailed analysis of the additives’ ability to migrate. It is concluded that while post-stretching decreased the migration rate, heat-setting seems to boost this migration.« less

  17. Results and Analysis of the Infrastructure Request for Information (DE-SOL-0008318)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heidrich, Brenden John

    2015-07-01

    The Department of Energy (DOE) Office of Nuclear Energy (NE) released a request for information (RFI) (DE-SOL-0008318) for “University, National Laboratory, Industry and International Input on Potential Office of Nuclear Energy Infrastructure Investments” on April 13, 2015. DOE-NE solicited information on five specific types of capabilities as well as any others suggested by the community. The RFI proposal period closed on June 19, 2015. From the 26 responses, 34 individual proposals were extracted. Eighteen were associated with a DOE national laboratory, including Argonne National Laboratory (ANL), Brookhaven National Laboratory (BNL), Idaho National Laboratory (INL), Los Alamos National Laboratory (LANL), Pacificmore » Northwest National Laboratory (PNNL) and Sandia National Laboratory (SNL). Oak Ridge National Laboratory (ORNL) was referenced in a proposal as a proposed capability location, although the proposal did not originate with ORNL. Five US universities submitted proposals (Massachusetts Institute of Technology, Pennsylvania State University, Rensselaer Polytechnic Institute, University of Houston and the University of Michigan). Three industrial/commercial institutions submitted proposals (AREVA NP, Babcock and Wilcox (B&W) and the Electric Power Research Institute (EPRI)). Eight major themes emerged from the submissions as areas needing additional capability or support for existing capabilities. Two submissions supported multiple areas. The major themes are: Advanced Manufacturing (AM), High Performance Computing (HPC), Ion Irradiation with X-Ray Diagnostics (IIX), Ion Irradiation with TEM Visualization (IIT), Radiochemistry Laboratories (RCL), Test Reactors, Neutron Sources and Critical Facilities (RX) , Sample Preparation and Post-Irradiation Examination (PIE) and Thermal-Hydraulics Test Facilities (THF).« less

  18. Plastic biofilm carrier after corn cobs reduces nitrate loading in laboratory denitrifying bioreactors

    USDA-ARS?s Scientific Manuscript database

    Nitrate-nitrogen removal rates can be increased substantially in denitrifying bioreactors with a corn cob bed medium compared to woodchips; however, additional organic carbon (C) is released into the effluent. This laboratory column experiment was conducted to test the performance of a post-bed cha...

  19. A user-friendly approach to cost accounting in laboratory animal facilities.

    PubMed

    Baker, David G

    2011-08-19

    Cost accounting is an essential management activity for laboratory animal facility management. In this report, the author describes basic principles of cost accounting and outlines steps for carrying out cost accounting in laboratory animal facilities. Methods of post hoc cost accounting analysis for maximizing the efficiency of facility operations are also described.

  20. Personal epistemological growth in a college chemistry laboratory environment

    NASA Astrophysics Data System (ADS)

    Keen-Rocha, Linda S.

    The nature of this study was to explore changes in beliefs and lay a foundation for focusing on more specific features of reasoning related to personal epistemological and NOS beliefs in light of specific science laboratory instructional pedagogical practices (e.g., pre- and post-laboratory activities, laboratory work) for future research. This research employed a mixed methodology, foregrounding qualitative data. The total population consisted of 56 students enrolled in several sections of a general chemistry laboratory course, with the qualitative analysis focusing on the in-depth interviews. A quantitative NOS and epistemological beliefs measure was administered pre- and post-instruction. These measures were triangulated with pre-post interviews to assure the rigor of the descriptions generated. Although little quantitative change in NOS was observed from the pre-post NSKS assessment a more noticeable qualitative change was reflected by the participants during their final interviews. The NSKS results: the mean gain scores for the overall score and all dimensions, except for amoral were found to be significant at p ≤ .05. However there was a more moderate change in the populations' broader epistemological beliefs (EBAPS) which was supported during the final interviews. The EBAPS results: the mean gain scores for the overall score and all dimensions, except for the source of ability to learn were found to be significant at p ≤ .05. The participants' identified the laboratory work as the most effective instructional feature followed by the post-laboratory activities. The pre-laboratory was identified as being the least effective feature. The participants suggested the laboratory work offered real-life experiences, group discussions, and teamwork which added understanding and meaning to their learning. The post-laboratory was viewed as necessary in tying all the information together and being able to see the bigger picture. What one cannot infer at this point is whether these belief changes and beliefs about laboratory instruction are enduring or whether some participants are simply more adaptable than others are to the learning environment. More research studies are needed to investigate the effects of laboratory instruction on student beliefs and understanding.

  1. LPT. Shield test facility test building interior (TAN646). Camera facing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Shield test facility test building interior (TAN-646). Camera facing south. Distant pool contained EBOR reactor; near pool was intended for fuel rod storage. Other post-1970 activity equipment remains in pool. INEEL negative no. HD-40-9-4 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  2. LPT. Shield test facility test building interior (TAN646). Camera points ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Shield test facility test building interior (TAN-646). Camera points down into interior of north pool. Equipment on wall is electronical bus used for post-1970 experiment. Personnel ladder at right. INEEL negative no. HD-40-9-1 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  3. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  4. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  5. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  6. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  7. Regional Lymph Node Uptake of [{sup 18}F]Fluorodeoxyglucose After Definitive Chemoradiation Therapy Predicts Local-Regional Failure of Locally Advanced Non-Small Cell Lung Cancer: Results of ACRIN 6668/RTOG 0235

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Markovina, Stephanie; Duan, Fenghai; Snyder, Bradley S.

    2015-11-01

    Purpose: The American College of Radiology Imaging Network (ACRIN) 6668/Radiation Therapy Oncology Group (RTOG) 0235 study demonstrated that standardized uptake values (SUV) on post-treatment [{sup 18}F]fluorodeoxyglucose-positron emission tomography (FDG-PET) correlated with survival in locally advanced non-small cell lung cancer (NSCLC). This secondary analysis determined whether SUV of regional lymph nodes (RLNs) on post-treatment FDG-PET correlated with patient outcomes. Methods and Materials: Included for analysis were patients treated with concurrent chemoradiation therapy, using radiation doses ≥60 Gy, with identifiable FDG-avid RLNs (distinct from primary tumor) on pretreatment FDG-PET, and post-treatment FDG-PET data. ACRIN core laboratory SUV measurements were used. Event time was calculatedmore » from the date of post-treatment FDG-PET. Local-regional failure was defined as failure within the treated RT volume and reported by the treating institution. Statistical analyses included Wilcoxon signed rank test, Kaplan-Meier curves (log rank test), and Cox proportional hazards regression modeling. Results: Of 234 trial-eligible patients, 139 (59%) had uptake in both primary tumor and RLNs on pretreatment FDG-PET and had SUV data from post-treatment FDG-PET. Maximum SUV was greater for primary tumor than for RLNs before treatment (P<.001) but not different post-treatment (P=.320). Post-treatment SUV of RLNs was not associated with overall survival. However, elevated post-treatment SUV of RLNs, both the absolute value and the percentage of residual activity compared to the pretreatment SUV were associated with inferior local-regional control (P<.001). Conclusions: High residual metabolic activity in RLNs on post-treatment FDG-PET is associated with worse local-regional control. Based on these data, future trials evaluating a radiation therapy boost should consider inclusion of both primary tumor and FDG-avid RLNs in the boost volume to maximize local-regional control.« less

  8. Reduction of genu recurvatum through adjustment of plantarflexion resistance of an articulated ankle-foot orthosis in individuals post stroke

    PubMed Central

    Kobayashi, Toshiki; Orendurff, Michael S.; Singer, Madeline L.; Gao, Fan; Daly, Wayne K.; Foreman, K. Bo

    2016-01-01

    Background Genu recurvatum (knee hyperextension) is a common issue for individuals post stroke. Ankle-foot orthoses are used to improve genu recurvatum, but evidence is limited concerning their effectiveness. Therefore, the aim of this study was to investigate the effect of changing the plantarflexion resistance of an articulated ankle-foot orthosis on genu recurvatum in patients post stroke. Methods Gait analysis was performed on 6 individuals post stroke with genu recurvatum using an articulated ankle-foot orthosis whose plantarflexion resistance was adjustable at four levels. Gait data were collected using a Bertec split-belt instrumented treadmill in a 3-dimensional motion analysis laboratory. Gait parameters were extracted and plotted for each subject under the four plantarflexion resistance conditions of the ankle-foot orthosis. Gait parameters included: a) peak ankle plantarflexion angle, b) peak ankle dorsiflexion moment, c) peak knee extension angle and d) peak knee flexion moment. A non-parametric Friedman test was performed followed by a post-hoc Wilcoxon Signed-Rank test for statistical analyses. Findings All the gait parameters demonstrated statistically significant differences among the four resistance conditions of the AFO. Increasing the amount of plantarflexion resistance of the ankle-foot orthosis generally reduced genu recurvatum in all subjects. However, individual analyses showed that the responses to the changes in the plantarflexion resistance of the AFO were not necessarily linear, and appear unique to each subject. Interpretations The plantarflexion resistance of an articulated AFO should be adjusted to improve genu recurvatum in patients post stroke. Future studies should investigate what clinical factors would influence the individual differences. PMID:27136122

  9. The Impact of Inquiry Based Instruction on Science Process Skills and Self-Efficacy Perceptions of Pre-Service Science Teachers at a University Level Biology Laboratory

    ERIC Educational Resources Information Center

    Sen, Ceylan; Sezen Vekli, Gülsah

    2016-01-01

    The aim of this study is to determine the influence of inquiry-based teaching approach on pre-service science teachers' laboratory self-efficacy perceptions and scientific process skills. The quasi experimental model with pre-test-post-test control group design was used as an experimental design in this research. The sample of this study included…

  10. COBRA-WC pretest predictions and post-test analysis of the FOTA temperature distribution during FFTF natural-circulation transients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khan, E.U.; George, T.L.; Rector, D.R.

    The natural circulation tests of the Fast Flux Test Facility (FFTF) demonstrated a safe and stable transition from forced convection to natural convection and showed that natural convection may adequately remove decay heat from the reactor core. The COBRA-WC computer code was developed by the Pacific Northwest laboratory (PNL) to account for buoyancy-induced coolant flow redistribution and interassembly heat transfer, effects that become important in mitigating temperature gradients and reducing reactor core temperatures when coolant flow rate in the core is low. This report presents work sponsored by the US Department of Energy (DOE) with the objective of checking themore » validity of COBRA-WC during the first 220 seconds (sec) of the FFTF natural-circulation (plant-startup) tests using recorded data from two instrumented Fuel Open Test Assemblies (FOTAs). Comparison of COBRA-WC predictions of the FOTA data is a part of the final confirmation of the COBRA-WC methodology for core natural-convection analysis.« less

  11. Students’ Perception of Self-Efficacy Following Medicinal Chemistry Skills Laboratory Exercises

    PubMed Central

    Roche, Victoria F.; Qi, Yongyue

    2016-01-01

    Objective. To analyze student perceptions of self-efficacy in meeting medicinal chemistry course related educational outcomes and skills following a medicinal chemistry skills laboratory. Methods. Four activities were implemented in a pharmacy skills laboratory (PSL) for second-year pharmacy students. Students (n=121) worked individually on exercises for three of the four activities. Pre/post-laboratory surveys on self-efficacy were administered. The McNemar test was performed to evaluate students’ self-efficacy above 70% related to course outcomes before and after the exercises in each activity. An independent t test was conducted to compare the mean of students’ responses on meeting course outcomes based on the 70% anchor for the perspective confidence on meeting course outcomes. Results. The post-PSL scores on all self-efficacy questions improved. The majority of students reported skill development in all exercises. Students and clinical faculty qualitative responses indicated they felt exercises were effective. Conclusion. A PSL can serve as a valuable opportunity to address course related educational outcomes and specific skill development and can help students assess their self-efficacy in meeting them. PMID:27402979

  12. Students' Perception of Self-Efficacy Following Medicinal Chemistry Skills Laboratory Exercises.

    PubMed

    Alsharif, Naser Z; Roche, Victoria F; Qi, Yongyue

    2016-06-25

    Objective. To analyze student perceptions of self-efficacy in meeting medicinal chemistry course related educational outcomes and skills following a medicinal chemistry skills laboratory. Methods. Four activities were implemented in a pharmacy skills laboratory (PSL) for second-year pharmacy students. Students (n=121) worked individually on exercises for three of the four activities. Pre/post-laboratory surveys on self-efficacy were administered. The McNemar test was performed to evaluate students' self-efficacy above 70% related to course outcomes before and after the exercises in each activity. An independent t test was conducted to compare the mean of students' responses on meeting course outcomes based on the 70% anchor for the perspective confidence on meeting course outcomes. Results. The post-PSL scores on all self-efficacy questions improved. The majority of students reported skill development in all exercises. Students and clinical faculty qualitative responses indicated they felt exercises were effective. Conclusion. A PSL can serve as a valuable opportunity to address course related educational outcomes and specific skill development and can help students assess their self-efficacy in meeting them.

  13. LPT. Shield test facility assembly and test building (TAN646), south ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Shield test facility assembly and test building (TAN-646), south facade. Camera facing north. High-bay section is pool room. Single-story section at right is control building (TAN-645). Small metal building is post-1970 addition. INEEL negative no. HD-40-7-3 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  14. LPT. Shield test control building (TAN645), north facade. Camera facing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Shield test control building (TAN-645), north facade. Camera facing south. Obsolete sign dating from post-1970 program says "Energy and Systems Technology Experimental Facility, INEL." INEEL negative no. HD-40-5-4 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  15. Assessment of readiness for clinical decision support to aid laboratory monitoring of immunosuppressive care at U.S. liver transplant centers.

    PubMed

    Jacobs, J; Weir, C; Evans, R S; Staes, C

    2014-01-01

    Following liver transplantation, patients require lifelong immunosuppressive care and monitoring. Computerized clinical decision support (CDS) has been shown to improve post-transplant immunosuppressive care processes and outcomes. The readiness of transplant information systems to implement computerized CDS to support post-transplant care is unknown. a) Describe the current clinical information system functionality and manual and automated processes for laboratory monitoring of immunosuppressive care, b) describe the use of guidelines that may be used to produce computable logic and the use of computerized alerts to support guideline adherence, and c) explore barriers to implementation of CDS in U.S. liver transplant centers. We developed a web-based survey using cognitive interviewing techniques. We surveyed 119 U.S. transplant programs that performed at least five liver transplantations per year during 2010-2012. Responses were summarized using descriptive analyses; barriers were identified using qualitative methods. Respondents from 80 programs (67% response rate) completed the survey. While 98% of programs reported having an electronic health record (EHR), all programs used paper-based manual processes to receive or track immunosuppressive laboratory results. Most programs (85%) reported that 30% or more of their patients used external laboratories for routine testing. Few programs (19%) received most external laboratory results as discrete data via electronic interfaces while most (80%) manually entered laboratory results into the EHR; less than half (42%) could integrate internal and external laboratory results. Nearly all programs had guidelines regarding pre-specified target ranges (92%) or testing schedules (97%) for managing immunosuppressive care. Few programs used computerized alerting to notify transplant coordinators of out-of-range (27%) or overdue laboratory results (20%). Use of EHRs is common, yet all liver transplant programs were largely dependent on manual paper-based processes to monitor immunosuppression for post-liver transplant patients. Similar immunosuppression guidelines provide opportunities for sharing CDS once integrated laboratory data are available.

  16. Recommendations for Filler Material Composition and Delivery Method for Bench-Scale Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardin, Ernest; Brady, Patrick Vane

    This report supplements Joint Workplan on Filler Investigations for DPCs (SNL 2017) providing new and some corrected information for use in planning Phase 1 laboratory testing of slurry cements as possible DPC fillers. The scope description is to "Describe a complete laboratory testing program for filler composition, delivery, emplacement in surrogate canisters, and post-test examination. To the extent possible specify filler material and equipment sources." This report includes results from an independent expert review (Dr. Arun Wagh, retired from Argonne National Laboratory and contracted by Sandia) that helped to narrow the range of cement types for consideration, and to providemore » further guidance on mix variations to optimize injectability, durability, and other aspects of filler performance.« less

  17. Calculating cost savings in utilization management.

    PubMed

    MacMillan, Donna

    2014-01-01

    A major motivation for managing the utilization of laboratory testing is to reduce the cost of medical care. For this reason it is important to understand the basic principles of cost accounting in the clinical laboratory. The process of laboratory testing includes three distinct components termed the pre-analytic, analytic and post-analytic phases. Utilization management efforts may impact the cost structure of these three phases in different ways depending on the specific details of the initiative. Estimates of cost savings resulting from utilization management programs reported in the literature have often been fundamentally flawed due to a failure to understand basic concepts such as the difference between laboratory costs versus charges and the impact of reducing laboratory test volumes on the average versus marginal cost structure in the laboratory. This article will provide an overview of basic cost accounting principles in the clinical laboratory including both job order and process cost accounting. Specific examples will be presented to illustrate these concepts in various different scenarios. © 2013.

  18. Students' perceptions of laboratory science careers: changing ideas with an education module.

    PubMed

    Haun, Daniel; Leach, Argie; Lawrence, Louann; Jarreau, Patsy

    2005-01-01

    To assess the effectiveness of a Web-based education module in changing students' perceptions of laboratory science careers. Perception was measured with a short examination and then a Web-based exercise was presented. Following the exercise, the test was administered again. Frequency data from the pre-test and post-test were compared for changes in perception. The correlated pre-test/post-test pairs were also examined for opinion changes and these were analyzed for significance. Large parochial high schools in New Orleans, Louisiana. A small team visited the schools during their appointed class times for biology. Study participants were high school biology students in grades 9-10. Two-hundred-forty-five students participated (149 male and 96 female). A Web-based exercise on blood film examination was presented to the students in a classroom setting (www.mclno.org/labpartners/index_03.htm). The exercise contained focused messages about: (1) the numbers of healthcare workers acquiring AIDS from on-the-job exposure and (2) common career paths available to the laboratory science workforce. The shift in perception of: What medical service generates the most diagnostic data. Which professional group performs laboratory tests. The risk of acquiring AIDS while working in the healthcare setting. Interest in a science-related career. How much education is required to work in a science-related field. The intervention significantly shifted perception in all areas measured except that of interest in a science-related career. Many students perceive that the risk of acquiring AIDS while working in the healthcare setting is "high". Web-based presentations and similar partnerships with science teachers can change perceptions that might lead to increased interest in clinical laboratory science careers.

  19. Anatomy and humanity: Examining the effects of a short documentary film and first anatomy laboratory experience on medical students.

    PubMed

    Dosani, Farah; Neuberger, Lindsay

    2016-01-01

    Medical students begin their education inside a laboratory dissecting cadavers to learn human gross anatomy. Many schools use the course experience as a way to instill empathy and some have begun integrating video and recorded interviews with body donors to humanize the experience, but their impact has yet to be measured. This study examines the effects of a brief documentary film and the initial cadaver encounter on student perceptions and attitudes towards the laboratory experience. A pre-test, exposure, post-test design was used with 77 first-year medical students at the University of Central Florida. A previously validated questionnaire was adapted to measure attitudes, emotions, initial reaction to cadaver, perception of the donor as a person, and impressions of the film. An online questionnaire was completed before the first day of laboratory, in which students watched the film Anatomy and Humanity and handled their respective cadavers (no dissection was performed). The post-test was administered immediately following the activities of the first laboratory day. Results indicate an increase in negative attitudes towards dissection, but a more positive initial reaction to the cadaver than originally anticipated. Students also experienced a decrease in emotions like sadness and guilt regarding anatomy laboratory and were less likely to view the cadaver as a once-living person. Findings suggest a higher comfort level, but also greater detachment toward the cadavers from day one despite the video intervention. These results provide novel insight that may aid other interventions aimed at promoting humanism in the anatomy laboratory experience. © 2015 American Association of Anatomists.

  20. Quality Indicators in Laboratory Medicine: from theory to practice. Preliminary data from the IFCC Working Group Project "Laboratory Errors and Patient Safety".

    PubMed

    Sciacovelli, Laura; O'Kane, Maurice; Skaik, Younis Abdelwahab; Caciagli, Patrizio; Pellegrini, Cristina; Da Rin, Giorgio; Ivanov, Agnes; Ghys, Timothy; Plebani, Mario

    2011-05-01

    The adoption of Quality Indicators (QIs) has prompted the development of tools to measure and evaluate the quality and effectiveness of laboratory testing, first in the hospital setting and subsequently in ambulatory and other care settings. While Laboratory Medicine has an important role in the delivery of high-quality care, no consensus exists as yet on the use of QIs focussing on all steps of the laboratory total testing process (TTP), and further research in this area is required. In order to reduce errors in laboratory testing, the IFCC Working Group on "Laboratory Errors and Patient Safety" (WG-LEPS) developed a series of Quality Indicators, specifically designed for clinical laboratories. In the first phase of the project, specific QIs for key processes of the TTP were identified, including all the pre-, intra- and post-analytic steps. The overall aim of the project is to create a common reporting system for clinical laboratories based on standardized data collection, and to define state-of-the-art and Quality Specifications (QSs) for each QI independent of: a) the size of organization and type of activities; b) the complexity of processes undertaken; and c) different degree of knowledge and ability of the staff. The aim of the present paper is to report the results collected from participating laboratories from February 2008 to December 2009 and to identify preliminary QSs. The results demonstrate that a Model of Quality Indicators managed as an External Quality Assurance Program can serve as a tool to monitor and control the pre-, intra- and post-analytical activities. It might also allow clinical laboratories to identify risks that lead to errors resulting in patient harm: identification and design of practices that eliminate medical errors; the sharing of information and education of clinical and laboratory teams on practices that reduce or prevent errors; the monitoring and evaluation of improvement activities.

  1. Powassan virus infection in snowshoe hares (Lepus americanus).

    PubMed

    Zarnke, R L; Yuill, T M

    1981-04-01

    Sera from snowshoe hares (Lepus americanus) trapped near Rochester, Alberta, Canada were tested for Powassan virus antibody by the constant virus/serum dilution neutralization test. Of 1264 serum samples tested, 137 had an antibody titer of at least 1:4 for Powassan virus. Ten hares were inoculated with Powassan virus in the laboratory. Viremia lasted 4-5 days and ceased with the appearance of Powassan antibody in the serum. Neutralizing antibody reached a peak titer of 1:119 on day 15 post-inoculation and was still detectable 13 months post-inoculation.

  2. 12. "OBSERVATION POSTS, STRUCTURAL PLANS AND DETAILS." Specifications No. OC25572; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. "OBSERVATION POSTS, STRUCTURAL PLANS AND DETAILS." Specifications No. OC2-55-72; Drawing No. 60-09-12; sheet 89 of 148; file no. 1321/40, Rev. A. Very faint stamp above note reads: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunkers for Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  3. PLACE: an open-source python package for laboratory automation, control, and experimentation.

    PubMed

    Johnson, Jami L; Tom Wörden, Henrik; van Wijk, Kasper

    2015-02-01

    In modern laboratories, software can drive the full experimental process from data acquisition to storage, processing, and analysis. The automation of laboratory data acquisition is an important consideration for every laboratory. When implementing a laboratory automation scheme, important parameters include its reliability, time to implement, adaptability, and compatibility with software used at other stages of experimentation. In this article, we present an open-source, flexible, and extensible Python package for Laboratory Automation, Control, and Experimentation (PLACE). The package uses modular organization and clear design principles; therefore, it can be easily customized or expanded to meet the needs of diverse laboratories. We discuss the organization of PLACE, data-handling considerations, and then present an example using PLACE for laser-ultrasound experiments. Finally, we demonstrate the seamless transition to post-processing and analysis with Python through the development of an analysis module for data produced by PLACE automation. © 2014 Society for Laboratory Automation and Screening.

  4. A comparison of traditional physical laboratory and computer-simulated laboratory experiences in relation to engineering undergraduate students' conceptual understandings of a communication systems topic

    NASA Astrophysics Data System (ADS)

    Javidi, Giti

    2005-07-01

    This study was designed to investigate an alternative to the use of traditional physical laboratory activities in a communication systems course. Specifically, this study examined whether as an alternative, computer simulation is as effective as physical laboratory activities in teaching college-level electronics engineering education students about the concepts of signal transmission, modulation and demodulation. Eighty undergraduate engineering students participated in the study, which was conducted at a southeastern four-year university. The students were randomly assigned to two groups. The groups were compared on understanding the concepts, remembering the concepts, completion time of the lab experiments and perception toward the laboratory experiments. The physical group's (n = 40) treatment was to conduct laboratory experiments in a physical laboratory. The students in this group used equipment in a controlled electronics laboratory. The Simulation group's (n = 40) treatment was to conduct similar experiments in a PC laboratory. The students in this group used a simulation program in a controlled PC lab. At the completion of the treatment, scores on a validated conceptual test were collected once after the treatment and again three weeks after the treatment. Attitude surveys and qualitative study were administered at the completion of the treatment. The findings revealed significant differences, in favor of the simulation group, between the two groups on both the conceptual post-test and the follow-up test. The findings also revealed significant correlation between simulation groups' attitude toward the simulation program and their post-test scores. Moreover, there was a significant difference between the two groups on their attitude toward their laboratory experience in favor of the simulation group. In addition, there was significant difference between the two groups on their lab completion time in favor of the simulation group. At the same time, the qualitative research has uncovered several issues not explored by the quantitative research. It was concluded that incorporating the recommendations acquired from the qualitative research, especially elements of incorporating hardware experience to avoid lack of hands-on skills, into the laboratory pedagogy should help improve students' experience regardless of the environment in which the laboratory is conducted.

  5. Non-destructive evaluation of laboratory scale hydraulic fracturing using acoustic emission

    NASA Astrophysics Data System (ADS)

    Hampton, Jesse Clay

    The primary objective of this research is to develop techniques to characterize hydraulic fractures and fracturing processes using acoustic emission monitoring based on laboratory scale hydraulic fracturing experiments. Individual microcrack AE source characterization is performed to understand the failure mechanisms associated with small failures along pre-existing discontinuities and grain boundaries. Individual microcrack analysis methods include moment tensor inversion techniques to elucidate the mode of failure, crack slip and crack normal direction vectors, and relative volumetric deformation of an individual microcrack. Differentiation between individual microcrack analysis and AE cloud based techniques is studied in efforts to refine discrete fracture network (DFN) creation and regional damage quantification of densely fractured media. Regional damage estimations from combinations of individual microcrack analyses and AE cloud density plotting are used to investigate the usefulness of weighting cloud based AE analysis techniques with microcrack source data. Two granite types were used in several sample configurations including multi-block systems. Laboratory hydraulic fracturing was performed with sample sizes ranging from 15 x 15 x 25 cm3 to 30 x 30 x 25 cm 3 in both unconfined and true-triaxially confined stress states using different types of materials. Hydraulic fracture testing in rock block systems containing a large natural fracture was investigated in terms of AE response throughout fracture interactions. Investigations of differing scale analyses showed the usefulness of individual microcrack characterization as well as DFN and cloud based techniques. Individual microcrack characterization weighting cloud based techniques correlated well with post-test damage evaluations.

  6. The Advantages of Using Planned Comparisons over Post Hoc Tests.

    ERIC Educational Resources Information Center

    Kuehne, Carolyn C.

    There are advantages to using a priori or planned comparisons rather than omnibus multivariate analysis of variance (MANOVA) tests followed by post hoc or a posteriori testing. A small heuristic data set is used to illustrate these advantages. An omnibus MANOVA test was performed on the data followed by a post hoc test (discriminant analysis). A…

  7. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  8. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  9. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  10. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  11. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  12. TESTING AND PERFORMANCE ANALYSIS OF NASA 5 CM BY 5 CM BI-SUPPORTED SOLID OXIDE ELECTROLYSIS CELLS OPERATED IN BOTH FUEL CELL AND STEAM ELECTROLYSIS MODES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. C. O'Brien; J. E. O'Brien; C. M. Stoots

    A series of 5 cm by 5 cm bi-supported Solid Oxide Electrolysis Cells (SOEC) were produced by NASA for the Idaho National Laboratory (INL) and tested under the INL High Temperature Steam Electrolysis program. The results from the experimental demonstration of cell operation for both hydrogen production and operation as fuel cells is presented. An overview of the cell technology, test apparatus and performance analysis is also provided. The INL High Temperature Steam Electrolysis laboratory has developed significant test infrastructure in support of single cell and stack performance analyses. An overview of the single cell test apparatus is presented. Themore » test data presented in this paper is representative of a first batch of NASA's prototypic 5 cm by 5 cm SOEC single cells. Clearly a significant relationship between the operational current density and cell degradation rate is evident. While the performance of these cells was lower than anticipated, in-house testing at NASA Glenn has yielded significantly higher performance and lower degradation rates with subsequent production batches of cells. Current post-test microstructure analyses of the cells tested at INL will be published in a future paper. Modification to cell compositions and cell reduction techniques will be altered in the next series of cells to be delivered to INL with the aim to decrease the cell degradation rate while allowing for higher operational current densities to be sustained. Results from the testing of new batches of single cells will be presented in a future paper.« less

  13. Student Understanding of Time in an Introductory Astronomy Laboratory

    NASA Astrophysics Data System (ADS)

    Traxler, A. L.; Batuski, D. J.; Comins, N. F.; Thompson, J. R.

    2005-09-01

    The astronomy lab at the University of Maine consists of discrete weekly lessons in which students work in small groups. Individual pretests and post-tests accompany each lesson. The lesson studied here covers the topic of time, including sidereal time, Apparent Solar Time, and time zones. The pretest consists of four multiple-choice questions, which are also administered after instruction as a post-test. In the fall 2004 semester, the pretest was rewritten to focus on some major conceptual components of the lab, while the lesson materials were not modified from previous years. Examination of class performance (n = 96) revealed no significant improvements in score from pre- to post-lesson. In the spring 2005 semester, the lesson was altered to incorporate the Starry Night software for simulating the sky instead of the celestial sphere models previously used. The goal of the change was to give students a more interactive environment for completing the laboratory exercise, which was otherwise altered as little as possible. Data from the spring semester show some gains on the pre/post-test questions covering sidereal time and Daylight Savings Time. Results to date have informed planned modifications to the lesson. A. L. T. was supported during this research by the University of Maine through a Provost Fellowship.

  14. Performance of AGR-1 high-temperature reactor fuel during post-irradiation heating tests

    DOE PAGES

    Morris, Robert N.; Baldwin, Charles A.; Demkowicz, Paul A.; ...

    2016-05-18

    The fission product retention of irradiated low-enriched uranium oxide/uranium carbide tri-structural isotropic (TRISO) fuel compacts from the Advanced Gas-Cooled Reactor 1 (AGR-1) experiment has been evaluated at temperatures of 1600–1800 °C during post-irradiation safety tests. Fourteen compacts (a total of ~58,000 particles) with a burnup ranging from 13.4% to 19.1% fissions per initial metal atom (FIMA) have been tested using dedicated furnace systems at Idaho National Laboratory and Oak Ridge National Laboratory. The release of fission products 110mAg, 134Cs, 137Cs, 154Eu, 155Eu, 90Sr, and 85Kr was monitored while heating the fuel specimens in flowing helium. The behavior of silver, europium,more » and strontium appears to be dominated by inventory that was originally released through intact SiC coating layers during irradiation, but was retained in the compact at the end of irradiation and subsequently released during the safety tests. However, at a test temperature of 1800 °C, the data suggest that release of these elements through intact coatings may become significant after ~100 h. Cesium was very well retained by intact SiC layers, with a fractional release <5 × 10–6 after 300 h at 1600 °C or 100 h at 1800 °C. However, it was rapidly released from individual particles if the SiC layer failed, and therefore the overall cesium release fraction was dominated by the SiC defect and failure fractions in the fuel compacts. No complete TRISO coating layer failures were observed after 300 h at 1600 or 1700 °C, and 85Kr release was very low during the tests (particles with failed SiC, but intact outer pyrocarbon, retained most of their krypton). Krypton release from TRISO failures was only observed after ~210 h at 1800 °C in one compact. As a result, post-safety-test examination of fuel compacts and particles has focused on identifying specific particles from each compact with notable fission product release and detailed analysis of the coating layers to understand particle behavior.« less

  15. Performance of AGR-1 high-temperature reactor fuel during post-irradiation heating tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morris, Robert N.; Baldwin, Charles A.; Demkowicz, Paul A.

    The fission product retention of irradiated low-enriched uranium oxide/uranium carbide tri-structural isotropic (TRISO) fuel compacts from the Advanced Gas-Cooled Reactor 1 (AGR-1) experiment has been evaluated at temperatures of 1600–1800 °C during post-irradiation safety tests. Fourteen compacts (a total of ~58,000 particles) with a burnup ranging from 13.4% to 19.1% fissions per initial metal atom (FIMA) have been tested using dedicated furnace systems at Idaho National Laboratory and Oak Ridge National Laboratory. The release of fission products 110mAg, 134Cs, 137Cs, 154Eu, 155Eu, 90Sr, and 85Kr was monitored while heating the fuel specimens in flowing helium. The behavior of silver, europium,more » and strontium appears to be dominated by inventory that was originally released through intact SiC coating layers during irradiation, but was retained in the compact at the end of irradiation and subsequently released during the safety tests. However, at a test temperature of 1800 °C, the data suggest that release of these elements through intact coatings may become significant after ~100 h. Cesium was very well retained by intact SiC layers, with a fractional release <5 × 10–6 after 300 h at 1600 °C or 100 h at 1800 °C. However, it was rapidly released from individual particles if the SiC layer failed, and therefore the overall cesium release fraction was dominated by the SiC defect and failure fractions in the fuel compacts. No complete TRISO coating layer failures were observed after 300 h at 1600 or 1700 °C, and 85Kr release was very low during the tests (particles with failed SiC, but intact outer pyrocarbon, retained most of their krypton). Krypton release from TRISO failures was only observed after ~210 h at 1800 °C in one compact. As a result, post-safety-test examination of fuel compacts and particles has focused on identifying specific particles from each compact with notable fission product release and detailed analysis of the coating layers to understand particle behavior.« less

  16. Experimental investigation on the fracture behaviour of black shale by acoustic emission monitoring and CT image analysis during uniaxial compression

    NASA Astrophysics Data System (ADS)

    Wang, Y.; Li, C. H.; Hu, Y. Z.

    2018-04-01

    Plenty of mechanical experiments have been done to investigate the deformation and failure characteristics of shale; however, the anisotropic failure mechanism has not been well studied. Here, laboratory Uniaxial Compressive Strength tests on cylindrical shale samples obtained by drilling at different inclinations to bedding plane were performed. The failure behaviours of the shale samples were studied by real-time acoustic emission (AE) monitoring and post-test X-ray computer tomography (CT) analysis. The experimental results suggest that the pronounced bedding planes of shale have a great influence on the mechanical properties and AE patterns. The AE counts and AE cumulative energy release curves clearly demonstrate different morphology, and the `U'-shaped curve relationship between the AE counts, AE cumulative energy release and bedding inclination was first documented. The post-test CT image analysis shows the crack patterns via 2-D image reconstructions, an index of stimulated fracture density is defined to represent the anisotropic failure mode of shale. What is more, the most striking finding is that the AE monitoring results are in good agreement with the CT analysis. The structural difference in the shale sample is the controlling factor resulting in the anisotropy of AE patterns. The pronounced bedding structure in the shale formation results in an anisotropy of elasticity, strength and AE information from which the changes in strength dominate the entire failure pattern of the shale samples.

  17. TSP Symposium 2013 Proceedings

    DTIC Science & Technology

    2014-01-01

    test and Post - test Results of the Experimental Group Our results show that the experimental group improved on the post - test compared...4.3.4 Design of the Learning Strategy 27 4.4 Results 28 4.4.1 Post - test 28 4.4.2 Analysis of the Results 28 4.4.3 Analysis of the Results from the...Estimation Accuracy) 17 Figure 5: Methodology for the Research 24 Figure 6: Question 1, Time Control for Post - test 28 Figure 7:

  18. Three pedagogical approaches to introductory physics labs and their effects on student learning outcomes

    NASA Astrophysics Data System (ADS)

    Chambers, Timothy

    This dissertation presents the results of an experiment that measured the learning outcomes associated with three different pedagogical approaches to introductory physics labs. These three pedagogical approaches presented students with the same apparatus and covered the same physics content, but used different lab manuals to guide students through distinct cognitive processes in conducting their laboratory investigations. We administered post-tests containing multiple-choice conceptual questions and free-response quantitative problems one week after students completed these laboratory investigations. In addition, we collected data from the laboratory practical exam taken by students at the end of the semester. Using these data sets, we compared the learning outcomes for the three curricula in three dimensions of ability: conceptual understanding, quantitative problem-solving skill, and laboratory skills. Our three pedagogical approaches are as follows. Guided labs lead students through their investigations via a combination of Socratic-style questioning and direct instruction, while students record their data and answers to written questions in the manual during the experiment. Traditional labs provide detailed written instructions, which students follow to complete the lab objectives. Open labs provide students with a set of apparatus and a question to be answered, and leave students to devise and execute an experiment to answer the question. In general, we find that students performing Guided labs perform better on some conceptual assessment items, and that students performing Open labs perform significantly better on experimental tasks. Combining a classical test theory analysis of post-test results with in-lab classroom observations allows us to identify individual components of the laboratory manuals and investigations that are likely to have influenced the observed differences in learning outcomes associated with the different pedagogical approaches. Due to the novel nature of this research and the large number of item-level results we produced, we recommend additional research to determine the reproducibility of our results. Analyzing the data with item response theory yields additional information about the performance of our students on both conceptual questions and quantitative problems. We find that performing lab activities on a topic does lead to better-than-expected performance on some conceptual questions regardless of pedagogical approach, but that this acquired conceptual understanding is strongly context-dependent. The results also suggest that a single "Newtonian reasoning ability" is inadequate to explain student response patterns to items from the Force Concept Inventory. We develop a framework for applying polytomous item response theory to the analysis of quantitative free-response problems and for analyzing how features of student solutions are influenced by problem-solving ability. Patterns in how students at different abilities approach our post-test problems are revealed, and we find hints as to how features of a free-response problem influence its item parameters. The item-response theory framework we develop provides a foundation for future development of quantitative free-response research instruments. Chapter 1 of the dissertation presents a brief history of physics education research and motivates the present study. Chapter 2 describes our experimental methodology and discusses the treatments applied to students and the instruments used to measure their learning. Chapter 3 provides an introduction to the statistical and analytical methods used in our data analysis. Chapter 4 presents the full data set, analyzed using both classical test theory and item response theory. Chapter 5 contains a discussion of the implications of our results and a data-driven analysis of our experimental methods. Chapter 6 describes the importance of this work to the field and discusses the relevance of our research to curriculum development and to future work in physics education research.

  19. Laboratories | NREL

    Science.gov Websites

    | Z A Accelerated Exposure Testing Laboratory Advanced Optical Materials Laboratory Advanced Thermal Laboratory Structural Testing Laboratory Surface Analysis Laboratory Systems Performance Laboratory T Thermal Storage Materials Laboratory Thermal Storage Process and Components Laboratory Thin-Film Deposition

  20. LPT. Low power assembly and test building (TAN640). Camera facing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Low power assembly and test building (TAN-640). Camera facing west. Rollup doors to each test cell face east. Concrete walls poured in place. Apparatus at right of view was part of a post-ANP program. INEEL negative no. HD-40-1-1 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  1. 42 CFR 414.310 - Determination of reasonable charges for physician services furnished to renal dialysis patients.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Pre-dialysis and post-dialysis examinations, or examinations that could have been furnished on a pre-dialysis or post-dialysis basis. (4) Insertion of catheters for patients who are on peritoneal dialysis and... laboratory test results, nurses' notes and any other medical documentation, as a basis for— (i) Adjustment of...

  2. 42 CFR 414.310 - Determination of reasonable charges for physician services furnished to renal dialysis patients.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Pre-dialysis and post-dialysis examinations, or examinations that could have been furnished on a pre-dialysis or post-dialysis basis. (4) Insertion of catheters for patients who are on peritoneal dialysis and... laboratory test results, nurses' notes and any other medical documentation, as a basis for— (i) Adjustment of...

  3. LPT. Shield test facility assembly and test building (TAN646), south ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Shield test facility assembly and test building (TAN-646), south end of EBOR helium wing. Camera facing north. Monorail protrudes from upper-level door. Rust marks on concrete wall are from stack. Metal shed is post-1970 addition. INEEL negative no. HD-40-8-1 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  4. Effects of an Elastic Hamstring Assistance Device During Downhill Running

    PubMed Central

    Aldret, Randy L; Trahan, Brittany A; Davis, Greggory; Campbell, Brian; Bellar, David M

    2017-01-01

    Abstract The purpose of this study was to determine the appropriateness of using an elastic hamstring assistance device to reduce perceived levels of soreness, increase isometric strength, increase passive range of motion, and decrease biomarkers of muscle damage after eccentric exercise, specifically, downhill running This study was conducted in a university exercise physiology laboratory placing sixteen apparently healthy males (X = 21.6 ± 2.5 years) into two groups using a pre-test/post-test design. Pre-intervention measures taken included participants’ body height, body mass, body fat, capillary blood samples, VO2max, isometric hamstring strength at 45 and 90 degrees of flexion and passive hamstring range of motion. Post-intervention measures included blood biomarkers, passive range of motion, the perceived level of soreness and isometric strength. An analysis of normality of data was initially conducted followed by multivariate analysis of variance (MANOVA) of hamstring strength at 45 and 90 degrees of flexion, blood myoglobin and passive range of motion of the hamstrings. Statistically significant changes were noted in subject-perceived muscle soreness and isometric strength at 90 degrees at the 24-hour post-exercise trial measure between the two groups. Results would suggest the findings could be explained by the decrease in muscle soreness from utilizing the device during the exercise trial. Further research should be conducted to address sample size issues and to determine if the results are comparable on different surfaces. PMID:28713460

  5. Aerothermodynamic Insight From The HIFIRE Program

    NASA Astrophysics Data System (ADS)

    Kimmel, Roger L.; Adamczak, David; Dolvin, Douglas; Borg, Matthew; Stanfield, Scott

    2011-05-01

    The HIFiRE (Hypersonic International Flight Research and Experimentation) program is a joint venture of the United States Air Force Research Laboratory and Australian Defence Science and Technology Organisation to utilize economical flight research opportunities in the exploration of flight science issues for space access systems. Flights 1 and 5 focus on collecting high-resolution experimental data on critical aerothermodynamic phenomena, including laminar-turbulent transition and shock/boundary layer interactions. Flight 1, successfully flown in March 2010, employed a test article composed of a 7-deg right angle cone, followed by a cylinder and flare. The test article remained attached to the second-stage booster throughout the ballistic trajectory. Flight 5, to be launched in a similar fashion, will feature a 2:1 elliptic cross-section cone as the test article. For both flights significant resources have been invested in pre-flight aerothermodynamic analysis and testing. This manuscript will summarize the overall strategy of the HIFiRE program, review the pre-flight aerothermodynamic analysis for Flights 1 and 5, and present a brief look at preliminary results from the post-flight analysis of Flight 1.

  6. Space Station CMIF extended duration metabolic control test

    NASA Technical Reports Server (NTRS)

    Schunk, Richard G.; Bagdigian, Robert M.; Carrasquillo, Robyn L.; Ogle, Kathryn Y.; Wieland, Paul O.

    1989-01-01

    The Space Station Extended Duration Metabolic Control Test (EMCT) was conducted at the MSFC Core Module Integration Facility. The primary objective of the EMCT was to gather performance data from a partially-closed regenerative Environmental Control and Life Support (ECLS) system functioning under steady-state conditions. Included is a description of the EMCT configuration, a summary of events, a discussion of anomalies that occurred during the test, and detailed results and analysis from individual measurements of water and gas samples taken during the test. A comparison of the physical, chemical, and microbiological methods used in the post test laboratory analyses of the water samples is included. The preprototype ECLS hardware used in the test, providing an overall process description and theory of operation for each hardware item. Analytical results pertaining to a system level mass balance and selected system power estimates are also included.

  7. Severe paramethoxymethamphetamine (PMMA) and paramethoxyamphetamine (PMA) outbreak in Israel.

    PubMed

    Lurie, Yael; Gopher, Asher; Lavon, Ophir; Almog, Shlomo; Sulimani, Liron; Bentur, Yedidia

    2012-01-01

    Paramethoxymethamphetamine (PMMA) is a hallucinogenic synthetic substituted amphetamine that was not included in the Israeli Controlled Substance Act (CSA). To report a severe PMMA and paramethoxyamphetamine (PMA) outbreak. The Israeli national forensic toxicology laboratory analyzes the body fluids of unnatural deaths by means of screening immunoassays and chromatographic confirmation and quantification. Samples are referred to this laboratory by the Israeli Forensic Medicine Institute and by hospitals following consultation with the Israel Poison Information Center. The forensic toxicology laboratory began determining PMMA and PMA in February 2007. In all fatal cases with a positive immunoassay screen for amphetamines, a chromatographic analysis of PMA and PMMA was performed. The laboratory and demographic data of consecutive patients in whom PMMA or PMA were detected, were collected during 1 year and subjected to descriptive analysis. Of 108 fatal cases with a positive screen for amphetamines, 32 were confirmed. Twenty-four of the 32 cases tested positive for PMMA and PMA--age 27 ± 5 years, 79.2% males, post mortem whole blood PMMA and PMA concentrations 0.35 ± 0.24 and 2.72 ± 1.67 mcg/mL, respectively. Co-exposures were detected in 17 (70.8%) fatalities; including methylenedioxymethamphetamine, methylenedioxyamphetamine, cocaine, cannabinoids, cathinone derivatives, ephedrine/pseudoephedrine, opiates, and ethanol. In addition, five non-fatal male cases were identified; age 32 ± 5 years, four had co-exposures to cocaine, cathinone derivatives, and cannabinoids. These findings led to the inclusion of PMMA in the CSA in July 2007, resulting in only three more fatalities in the following year. We report an outbreak of PMMA and PMA poisoning resulting in 24 fatalities, and the post mortem whole blood and urine concentrations of these two compounds. PMA was probably the result of PMMA metabolism. Stimulant co-exposures may have contributed to the severity of the poisoning. Forensic laboratory and poison center co-operation is important in identifying a new drug of abuse.

  8. MOTOR ACTIVITY IN DEVELOPMENTAL NEUROTOXICITY TESTING: A CROSS-LABORATORY COMPARISON OF CONTROL DATA.

    EPA Science Inventory

    The USEPA Developmental Neurotoxicity (DNT) Study Test Guideline (OPPTS 870.6300) calls for a battery of functional and neuropathological assessments in offspring during and following maternal exposure. The battery includes measurement of motor activity on post-natal days (PND) ...

  9. The future of hospital laboratories. Position statement from the Royal Belgian Society of Clinical Chemistry (RBSCC).

    PubMed

    Langlois, Michel R; Wallemacq, Pierre

    2009-01-01

    To face the economic pressures arising from the current socio-economic conjuncture, hospital laboratories are endangered by an increasing trend towards the outsourcing of clinical laboratory tests to external (mega-) laboratories. This should allow hospitals to meet their economic requirements, but with an increased risk of loss of medical quality and, mid- to long-term, loss of cost effectiveness of healthcare at the national level. To anticipate current developments (economical and technological) that inevitably will affect the future of laboratory medicine, hospital laboratories should be proactive and enhance efficiency, reduce costs by consolidation, integrate into regional networks, and form alliances or partnerships. To create additional value, the core competency of laboratory professionals must be refocused to provide medical knowledge services (consultative support to clinicians) related to in vitro diagnostic testing. To integrate cost-efficiency with medical quality, implementation of a matricial organization - operational vs. biomedical level - could be an interesting approach. This integrated structure should create total quality of laboratory testing, managing the entire medical diagnostic cycle from the pre-preanalytical to post-postanalytical phase.

  10. Bio-repository of post-clinical test samples at the national cancer center hospital (NCCH) in Tokyo.

    PubMed

    Furuta, Koh; Yokozawa, Karin; Takada, Takako; Kato, Hoichi

    2009-08-01

    We established the Bio-repository at the National Cancer Center Hospital in October 2002. The main purpose of this article is to show the importance and usefulness of a bio-repository of post-clinical test samples not only for translational cancer research but also for routine clinical oncology by introducing the experience of setting up such a facility. Our basic concept of a post-clinical test sample is not as left-over waste, but rather as frozen evidence of a patient's pathological condition at a particular point. We can decode, if not all, most of the laboratory data from a post-clinical test sample. As a result, the bio-repository is able to provide not only the samples, but potentially all related laboratory data upon request. The areas of sample coverage are the following: sera after routine blood tests; sera after cross-match tests for transfusion; serum or plasma submitted at a patient's clinically important time period by the physician; and samples collected by the individual investigator. The formats of stored samples are plasma or serum, dried blood spot (DBS) and buffy coat. So far, 150 218 plasmas or sera, 35 253 DBS and 536 buffy coats have been registered for our bio-repository system. We arranged to provide samples to various concerned parties under strict legal and ethical agreements. Although the number of the utilized samples was initially limited, the inquiries for sample utilization are now increasing steadily from both research and clinical sources. Further efforts to increase the benefits of the repository are intended.

  11. KENNEDY SPACE CENTER, FLA. - Dr. Paul Hintze (left) explains to Center Director Jim Kennedy a project he is working at the KSC Beach Corrosion Test Site. Hitze is doing post-graduate work for the National Research Council. The test facility site was established in the 1960s and has provided more than 30 years of historical information on the long-term performance of many materials in use at KSC and other locations around the world. Located 100 feet from the Atlantic Ocean approximately 1 mile south of the Space Shuttle launch sites, the test facility includes an atmospheric exposure site, a flowing seawater exposure site, and an on-site electrochemistry laboratory and monitoring station. The beach laboratory is used to conduct real-time corrosion experiments and provides for the remote monitoring of surrounding weather conditions. The newly added flowing seawater immersion facility provides for the immersion testing of materials and devices under controlled conditions.

    NASA Image and Video Library

    2003-08-21

    KENNEDY SPACE CENTER, FLA. - Dr. Paul Hintze (left) explains to Center Director Jim Kennedy a project he is working at the KSC Beach Corrosion Test Site. Hitze is doing post-graduate work for the National Research Council. The test facility site was established in the 1960s and has provided more than 30 years of historical information on the long-term performance of many materials in use at KSC and other locations around the world. Located 100 feet from the Atlantic Ocean approximately 1 mile south of the Space Shuttle launch sites, the test facility includes an atmospheric exposure site, a flowing seawater exposure site, and an on-site electrochemistry laboratory and monitoring station. The beach laboratory is used to conduct real-time corrosion experiments and provides for the remote monitoring of surrounding weather conditions. The newly added flowing seawater immersion facility provides for the immersion testing of materials and devices under controlled conditions.

  12. Post-Flight Assessment of Avcoat Thermal Protection System for the Exploration Flight Test-1

    NASA Technical Reports Server (NTRS)

    Bose, Deepak; Santos, Jose; Rodriguez, Erika; Mahzari, Milad; Remark, Brian; Muppidi, Suman

    2016-01-01

    On December 5, 2014 NASA conducted the first flight test of its next generation human-class Orion spacecraft. The flight was called the Exploration Flight Test -1 (EFT-1) which lasted for 4 hours and culminated into a re-entry trajectory at 9 km/s. This flight test of the 5-meter Orion Crew Module demonstrated various sub-systems including the Avcoat ablative thermal protection system (TPS) on the heat shield. The Avcoat TPS had been developed from the Apollo-era recipe with a few key modifications. The engineering for thermal sizing was supported by modeling, analysis, and ground tests in arc jet facilities. This paper will describe a postlfight analysis plan and present results from post-recovery inspections, data analysis from embedded sensors, TPS sample extraction and characterization in the laboratory. After the recovery of the vehicle, a full photographic survey and surface scans of the TPS were performed. The recovered vehicle showed physical evidence of flow disturbances, varying degrees of surface roughness, and excessive recession downstream of compression pads. The TPS recession was measured at more than 200 locations of interest on the Avcoat surface. The heat shield was then processed for sample extraction prior to TPS removal using the 7-Axis Milling machine at Marshall Space Flight Center. Around 182 rectangular TPS samples were extracted for subsequent analysis and investigation. The final paper will also present results of sample analysis. The planned investigation includes sidewall imaging, followed by image analysis to characterize TPS response by quantifying different layers in the char and pyrolysis zones. A full postmortem of the instrumentation and sensor ports will also be performed to confirm no adverse effects due to the sensors themselves. A subset of the samples will undergo structural testing and perform detailed characterization of any cracks and integrity of gore seams. Finally, the material will be characterized with layer-by-layer density measurements and SEM investigations to evaluate material morphology at microstructural level including identification of elements and compounds.

  13. Heparin-induced thrombocytopenia: reducing misdiagnosis via collaboration between an inpatient anticoagulation pharmacy service and hospital reference laboratory.

    PubMed

    Burnett, Allison E; Bowles, Harmony; Borrego, Matthew E; Montoya, Tiffany N; Garcia, David A; Mahan, Charles

    2016-11-01

    Misdiagnosis of heparin-induced thrombocytopenia (HIT) is common and exposes patients to high-risk therapies and potentially serious adverse events. The primary objective of this study was to evaluate the impact of collaboration between an inpatient pharmacy-driven anticoagulation management service (AMS) and hospital reference laboratory to reduce inappropriate HIT antibody testing via pharmacist intervention and use of the 4T pre-test probability score. Secondary objectives included clinical outcomes and cost-savings realized through reduced laboratory testing and decreased unnecessary treatment of HIT. This was a single center, pre-post, observational study. The hospital reference laboratory contacted the AMS when they received a blood sample for an enzyme-linked immunosorbent HIT antibody (HIT Ab). Trained pharmacists prospectively scored each HIT Ab ordered by using the 4T score with subsequent communication to physicians recommending for or against processing and reporting of lab results. Utilizing retrospective chart review and a database for all patients with a HIT Ab ordered during the study period, we compared the incidence of HIT Ab testing before and after implementation of the pharmacy-driven 4T score intervention. Our intervention significantly reduced the number of inappropriate HIT Ab tests processed (176 vs. 63, p < 0.0001), with no increase in thrombotic or hemorrhagic events. Overall incidence of suspected and confirmed HIT was <3 and <0.005 %, respectively. Overall cost savings were $75,754 (US) or 62 % per patient exposed to heparin between the pre and post intervention groups. Collaboration between inpatient pharmacy AMS and hospital reference laboratories can result in reduction of misdiagnosis of HIT and significant cost savings with similar safety.

  14. Why Non-contact Tonometry Tests Cannot Evaluate the Effects of Corneal Collagen Cross-linking.

    PubMed

    Ortillés, Ángel; Rodríguez-Matas, José F; Ariza-Gracia, Miguel Á; Pascual, Gemma; Calvo, Begoña

    2017-03-01

    To assess the feasibility of characterizing and following up the mechanical behavior of the corneal tissue after corneal cross-linking (CXL) by using a combined mechanical (in vivo indentation and in vitro uniaxial tensile tests) and morphological (immunohisto-chemistry) experimental protocol. CXL (3 mW/cm 2 ; 370 nm) for 20 minutes (total dose 3.6 J/cm 2 ) was performed on 12 New Zealand rabbits. The mechanical behavior of the cornea was characterized in small and large strain regimens using an in vivo indentation test with a laboratory device and an in vitro uniaxial tensile test, respectively. These tests and corneal immunohistochemistry were performed before (PreCXL) and on the 7th (PostCXL-7d) and 56th days (PostCXL-56d) after CXL. The intraocular pressure and corneal thickness were measured before each test. For the indentation tests, significant differences were found between PreCXL and PostCXL-7d and between PostCXL-7d and PostCXL-56d, but not between PreCXL and PostCXL-56d. On average, for the small strain regimen, PostCXL-7d corneas showed the most compliant behavior, with progressive recovery of the corneal stiffness over time. For the large strain regimen, significant differences in the maximum tangent modulus between PreCXL and PostCXL-7d and between PreCXL and PostCXL-56d were observed for the uniaxial tensile tests, with no significant differences between PostCXL-7d and PostCXL-56d. Immunohistochemistry showed a lack of cells in the anterior stroma at PostCXL-7d, but at PostCXL-56d the cell density and morphology were comparable to PreCXL. Indentation tests cannot characterize the changes in the corneal collagen scaffold caused by the CXL, but the uniaxial test can. However, indentation tests can assess the recovery of keratocyte density after CXL. [J Refract Surg. 2017;33(3):184-192.]. Copyright 2017, SLACK Incorporated.

  15. 2. NORTH FRONT, FROM SUPERSTRUCTURE TO FLAME DEFLECTOR. Looking south ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. NORTH FRONT, FROM SUPERSTRUCTURE TO FLAME DEFLECTOR. Looking south southwest from Observation Post No. 1 (Building 8767). - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  16. The ATLAS project: The effects of a constructionist digital laboratory project on undergraduate laboratory performance.

    PubMed

    Shoepe, Todd C; Cavedon, Dana K; Derian, Joseph M; Levy, Celine S; Morales, Amy

    2015-01-01

    Anatomical education is a dynamic field where developments in the implementation of constructive, situated-learning show promise in improving student achievement. The purpose of this study was to examine the effectiveness of an individualized, technology heavy project in promoting student performance in a combined anatomy and physiology laboratory course. Mixed-methods research was used to compare two cohorts of anatomy laboratories separated by the adoption of a new laboratory atlas project, which were defined as preceding (PRE) and following the adoption of the Anatomical Teaching and Learning Assessment Study (ATLAS; POST). The ATLAS project required the creation of a student-generated, photographic atlas via acquisition of specimen images taken with tablet technology and digital microscope cameras throughout the semester. Images were transferred to laptops, digitally labeled and photo edited weekly, and compiled into a digital book using Internet publishing freeware for final project submission. An analysis of covariance confirmed that student final examination scores were improved (P < 0.05) following the implementation of the laboratory atlas project (PRE, n = 75; POST, n = 90; means ± SE; 74.9 ± 0.9 versus 78.1 ± 0.8, respectively) after controlling for cumulative student grade point average. Analysis of questionnaires collected (n = 68) from the post group suggested students identified with atlas objectives, appreciated the comprehensive value in final examination preparation, and the constructionism involved, but recommended alterations in assignment logistics and the format of the final version. Constructionist, comprehensive term-projects utilizing student-preferred technologies could be used to improve performance toward student learning outcomes. © 2014 American Association of Anatomists.

  17. Development and Testing of a Post-Installable Deepwater Monitoring System Using Fiber-Optic Sensors

    NASA Technical Reports Server (NTRS)

    Seaman, Calvin H.; Brower, David V.; Le, Suy Q.; Tang, Henry H.

    2015-01-01

    This paper addresses the design and development of a fiber-optic monitoring system that can be deployed on existing deepwater risers and flowlines; and provides a summary of test article fabrication and the subsequent laboratory testing performed at the National Aeronautics and Space Administration-Johnson Space Center (NASA-JSC). A major challenge of a post-installed instrumentation system is to ensure adequate coupling between the instruments and the riser or flowline of interest. This work investigates the sensor coupling for pipelines that are suspended in a water column (from topside platform to seabed) using a fiber-optic sensor clamp and subsea bonding adhesive. The study involved the design, fabrication, and test of several prototype clamps that contained fiber-optic sensors. A mold was produced by NASA using 3-D printing methods that allowed the casting of polyurethane clamp test articles to accommodate 4-inch and 8-inch diameter pipes. The prototype clamps were installed with a subsea adhesive in a "wet" environment and then tested in the NASA Structures Test Laboratory (STL). The tension, compression, and bending test data showed that the prototype sensor clamps achieved good structural coupling, and could provide high quality strain measurement for active monitoring.

  18. Has compliance with CLIA requirements really improved quality in US clinical laboratories?

    PubMed

    Ehrmeyer, Sharon S; Laessig, Ronald H

    2004-08-02

    The Clinical Laboratory Improvement Amendments of 1988 (CLIA'88) mandate universal requirements for all U.S. clinical laboratory-testing sites. The intent of CLIA'88 is to ensure quality testing through a combination of minimum quality practices that incorporate total quality management concepts. These regulations do not contain established, objective indicators or measures to assess quality. However, there is an implicit assumption that compliance with traditionally accepted good laboratory practices--following manufacturers' directions, routinely analysing quality control materials, applying quality assurance principles, employing and assessing competent testing personnel, and participating in external quality assessment or proficiency testing (PT)--will result in improved test quality. The CLIA'88 regulations do include PT performance standards, which intentionally or unintentionally, define intra-laboratory performance. Passing PT has become a prime motivation for improving laboratory performance; it can also be used as an objective indicator to assess whether compliance to CLIA has improved intra-laboratory quality. Data from 1994 through 2002 indicate that the percentage of laboratories passing PT has increased. In addition to PT performance, subjective indicators of improved quality--frequency of inspection deficiencies, the number of government sanctions for non-compliance, and customer satisfaction--were evaluated. The results from these subjective indicators are more difficult to interpret but also seem to show improved quality in US clinical laboratories eleven years post-CLIA'88.

  19. University of Wisconsin Ion Beam Laboratory: A facility for irradiated materials and ion beam analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Field, K. G.; Wetteland, C. J.; Cao, G.

    2013-04-19

    The University of Wisconsin Ion Beam Laboratory (UW-IBL) has recently undergone significant infrastructure upgrades to facilitate graduate level research in irradiated materials phenomena and ion beam analysis. A National Electrostatics Corp. (NEC) Torodial Volume Ion Source (TORVIS), the keystone upgrade for the facility, can produce currents of hydrogen ions and helium ions up to {approx}200 {mu}A and {approx}5 {mu}A, respectively. Recent upgrades also include RBS analysis packages, end station developments for irradiation of relevant material systems, and the development of an in-house touch screen based graphical user interface for ion beam monitoring. Key research facilitated by these upgrades includes irradiationmore » of nuclear fuels, studies of interfacial phenomena under irradiation, and clustering dynamics of irradiated oxide dispersion strengthened steels. The UW-IBL has also partnered with the Advanced Test Reactor National Scientific User Facility (ATR-NSUF) to provide access to the irradiation facilities housed at the UW-IBL as well as access to post irradiation facilities housed at the UW Characterization Laboratory for Irradiated Materials (CLIM) and other ATR-NSUF partner facilities. Partnering allows for rapid turnaround from proposed research to finalized results through the ATR-NSUF rapid turnaround proposal system. An overview of the UW-IBL including CLIM and relevant research is summarized.« less

  20. Sexual Self-Schemas in the Real World: Investigating the Ecological Validity of Language-Based Markers of Childhood Sexual Abuse

    PubMed Central

    Stanton, Amelia M.; Meston, Cindy M.

    2017-01-01

    Abstract This is the first study to examine language use and sexual self-schemas in natural language data extracted from posts to a large online forum. Recently, two studies applied advanced text analysis techniques to examine differences in language use and sexual self-schemas between women with and without a history of childhood sexual abuse. The aim of the current study was to test the ecological validity of the differences in language use and sexual self-schema themes that emerged between these two groups of women in the laboratory. Archival natural language data were extracted from a social media website and analyzed using LIWC2015, a computerized text analysis program, and other word counting approaches. The differences in both language use and sexual self-schema themes that manifested in recent laboratory research were replicated and validated in the large online sample. To our knowledge, these results provide the first empirical examination of sexual cognitions as they occur in the real world. These results also suggest that natural language analysis of text extracted from social media sites may be a potentially viable precursor or alternative to laboratory measurement of sexual trauma phenomena, as well as clinical phenomena, more generally. PMID:28570129

  1. PIE on Safety-Tested AGR-1 Compact 5-1-1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunn, John D.; Morris, Robert Noel; Baldwin, Charles A.

    Post-irradiation examination (PIE) is being performed in support of tristructural isotropic (TRISO) coated particle fuel development and qualification for High-Temperature Gas-cooled Reactors (HTGRs). AGR-1 was the first in a series of TRISO fuel irradiation experiments initiated in 2006 under the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program; this work continues to be funded by the Department of Energy's Office of Nuclear Energy as part of the Advanced Reactor Technologies (ART) initiative. AGR-1 fuel compacts were fabricated at Oak Ridge National Laboratory (ORNL) in 2006 and irradiated for three years in the Idaho National Laboratory (INL) Advanced Test Reactormore » (ATR) to demonstrate and evaluate fuel performance under HTGR irradiation conditions. PIE is being performed at INL and ORNL to study how the fuel behaved during irradiation, and to examine fuel performance during exposure to elevated temperatures at or above temperatures that could occur during a depressurized conduction cooldown event. This report summarizes safety testing of irradiated AGR-1 Compact 5-1-1 in the ORNL Core Conduction Cooldown Test Facility (CCCTF) and post-safety testing PIE.« less

  2. Advanced Post-Irradiation Examination Capabilities Alternatives Analysis Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeff Bryan; Bill Landman; Porter Hill

    2012-12-01

    An alternatives analysis was performed for the Advanced Post-Irradiation Capabilities (APIEC) project in accordance with the U.S. Department of Energy (DOE) Order DOE O 413.3B, “Program and Project Management for the Acquisition of Capital Assets”. The Alternatives Analysis considered six major alternatives: ? No Action ? Modify Existing DOE Facilities – capabilities distributed among multiple locations ? Modify Existing DOE Facilities – capabilities consolidated at a few locations ? Construct New Facility ? Commercial Partnership ? International Partnerships Based on the alternatives analysis documented herein, it is recommended to DOE that the advanced post-irradiation examination capabilities be provided by amore » new facility constructed at the Materials and Fuels Complex at the Idaho National Laboratory.« less

  3. 3. DETAIL OF NORTH FRONT AND WEST SIDE, WITH SUPERSTRUCTURE, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. DETAIL OF NORTH FRONT AND WEST SIDE, WITH SUPERSTRUCTURE, FROM NEAR OBSERVATION POST NO. 3. Looking south southeast from below. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  4. SMD 3 post test medical report

    NASA Technical Reports Server (NTRS)

    Hordinsky, J. R.

    1977-01-01

    One of several reports that were prepared to document the results of the Spacelab Mission Development Test 3 is presented. This report covers clinical support to the crew as well as assistance and counsel to others in crew selection, health stabilization of the crew and the laboratory animals, and habitability and duty schedules.

  5. Effectiveness of Field Trips in Teaching Groundwater Concepts.

    ERIC Educational Resources Information Center

    Pederson, Darryll T.

    1979-01-01

    The field trip procedures described were devised for use with freshman college students as an alternative to a classroom or laboratory session. Pre-test and post-test of students' knowledge of groundwater concepts show significant change in students' understanding of groundwater occurance and movement following such a trip. (RE)

  6. 40 CFR 258.41 - Project XL Bioreactor Landfill Projects.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... using the Standard Test Method for Measuring Mass per Unit Area of Geotextiles, ASTM D-5261-92... determined by the Standard Test Method for Laboratory Determination of Water (Moisture) Content of Soil and... with the provisions of the FESOP, during the entire period of leachate recirculation and the post...

  7. 40 CFR 258.41 - Project XL Bioreactor Landfill Projects.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... using the Standard Test Method for Measuring Mass per Unit Area of Geotextiles, ASTM D-5261-92... determined by the Standard Test Method for Laboratory Determination of Water (Moisture) Content of Soil and... with the provisions of the FESOP, during the entire period of leachate recirculation and the post...

  8. 40 CFR 258.41 - Project XL Bioreactor Landfill Projects.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... using the Standard Test Method for Measuring Mass per Unit Area of Geotextiles, ASTM D-5261-92... determined by the Standard Test Method for Laboratory Determination of Water (Moisture) Content of Soil and... with the provisions of the FESOP, during the entire period of leachate recirculation and the post...

  9. Effect of Metformin and Flutamide on Anthropometric Indices and Laboratory Tests in Obese/Overweight PCOS Women under Hypocaloric Diet.

    PubMed

    Amiri, Mania; Golsorkhtabaramiri, Masoumeh; Esmaeilzadeh, Sedigheh; Ghofrani, Faeze; Bijani, Ali; Ghorbani, Leila; Delavar, Moloud Agajani

    2014-10-01

    This study was designed to investigate the effect of metformin and flutamide alone or in combination with anthropometric indices and laboratory tests of obese/overweight PCOS women under hypocaloric diet. This single blind clinical trial was performed on 120 PCOS women. At the beginning, hypocaloric diet was recommended for the patients. After one month while they were on the diet, the patients were randomly divided in 4 groups; metformin (500 mg, 3/day), flutamide (250 mg, 2/day), combined, metformin (500 mg, 3/day) with flutamide (250 mg, 2/day) and finally placebo group. The patients were treated for 6 months. Anthropometric indices and laboratory tests (fasting and glucose-stimulated insulin levels, lipid profile and androgens) were measured. A one-way ANOVA (Post Hoc) and paired t-test were performed to analyze data. A p ≤ 0.05 was considered statistically significant. After treatment, reduction in weight, BMI, hip circumference was significantly greater in the metformin group in comparison to other groups (p<0.05). In addition, the fasting insulin was significantly greater in metformin group and flutamide group in comparison to metformin+flutamide and placebo groups after treatment (p<0.05). Within groups, insulin level showed significant changes (before and after treatment) in metformin+flutamide group and LDL reduction was significant in flutamide group before and after treatment. Post hoc tukey and two-tailed with p≤0.05 were used to define statistical significance. Using combination of metformin and flutamide improves anthropometric indices and laboratory tests in obese/overweight PCOS women under hypocaloric diet.

  10. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Standard hourly fee rate for laboratory testing, analysis, and other services. 91.37 Section 91.37 Agriculture Regulations of the Department of Agriculture... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and...

  11. Inhibition of Orthopaedic Implant Infections by Immunomodulatory Effects of Host Defense Peptides

    DTIC Science & Technology

    2014-12-01

    significance was determined by t- tests or by one-way analysis of variance (ANOVA) followed by Bonferroni post hoc tests in experiments with multiple...groups. Non- parametric Mann-Whitney tests , Kruskal-Wallis ANOVA followed by Newman-Kuels post hoc tests , or van Elteren’s two-way tests were applied to...in D, and black symbols in A), statistical analysis was by one-way ANOVA followed by Bonferroni versus control, post hoc tests . Otherwise, statistical

  12. National survey on turnaround time of clinical biochemistry tests in 738 laboratories in China.

    PubMed

    Zhang, Xiaoyan; Fei, Yang; Wang, Wei; Zhao, Haijian; Wang, Minqi; Chen, Bingquan; Zhou, Jie; Wang, Zhiguo

    2018-02-01

    This survey was initiated to estimate the current status of turnaround time (TAT) monitoring of clinical biochemistry in China, provide baseline data for establishment of quality specifications and analyze the impact factors of TAT. 738 laboratories were included. Questionnaires involved general information and data of related indicators of TAT during 1 week were provided to participating laboratories. Nine quality indicators were covered, which were medians, 90th and outlier rates of pre-examination, examination, and post-examination TAT. The 25th percentile, median, and 75th percentile of TATs were calculated as optimum, desirable, and minimum quality specifications. Percentages and sigma values were used to describe the outlier rates. Mann-Whitney and Kruskal-Wallis tests were used to identify the potential impacts of TAT. Response rate of this survey was 46.44%. More than 50% of the laboratories indicated they had set up target TATs in three time intervals and monitored TATs generally. The post-examination TAT of most laboratories was 0min, while the pre-examination and examination TAT varied. Sigma values of outlier rates for 45%~60% of laboratories were above 4, while 15%~20% of labs whose sigma values were below 3. Group comparisons suggested nurse or mechanical pipeline transportation, link laboratory information system with hospital information system, and using computer reporting instead of printing report were related to shorter TATs. Despite of the remarkable progresses of TATs in China, there was also room to improve. Laboratories should strengthen the construction of information systems, identify reasons for TAT delay to improve the service quality continuously. © 2017 Wiley Periodicals, Inc.

  13. Calf antibiotic and sulfonamide test (CAST) for screening antibiotic and sulfonamide residues in calf carcasses.

    PubMed

    Dey, Bhabani P; Reamer, Richard P; Thaker, Nitin H; Thaler, Alice M

    2005-01-01

    The Calf Antibiotic and Sulfonamide Test (CAST), a microbial inhibition screening test, was developed for detecting antibiotics and sulfonamides in bob veal calf carcasses. The test uses Bacillus megaterium ATCC 9885 as the indicator organism and Mueller Hinton agar as the growth medium. Compared to Swab Test on Premises (STOP), developed in 1970, this screening test has higher sensitivity and the ability to detect a wider range of veterinary antimicrobial residual drugs, particularly sulfonamides, at lower concentrations. Carcasses that are tested with CAST and suspected of containing chemical residue above tolerance level are retained for confirmation. Disposition of these carcasses are determined upon laboratory result. Routine testing of bob veal calves with CAST allowed the Food Safety and Inspection Service to release most calf carcasses within 24 h post-slaughter, thus conserving shipping and handling resources. However, changes in the regulation in 1990 dictate that disposition of carcasses found to contain violative levels of sulfonamide residues should be based on laboratory findings. The analysis of the data for the years 1990-1994 and 1998 indicate that the use of CAST over the years was significant, and had a direct impact on reduction of residue violations in veal carcasses. With the use of CAST, potentially harmful antimicrobial chemicals entering the human food chain through veal meat have been minimized.

  14. Cost analysis in the toxicology laboratory.

    PubMed

    Travers, E M

    1990-09-01

    The process of determining laboratory sectional and departmental costs and test costs for instrument-generated and manually generated reportable results for toxicology laboratories has been outlined in this article. It is hoped that the basic principles outlined in the preceding text will clarify and elucidate one of the most important areas needed for laboratory fiscal integrity and its survival in these difficult times for health care providers. The following general principles derived from this article are helpful aids for managers of toxicology laboratories. 1. To manage a cost-effective, efficient toxicology laboratory, several factors must be considered: the laboratory's instrument configuration, test turnaround time needs, the test menu offered, the analytic methods used, the cost of labor based on time expended and the experience and educational level of the staff, and logistics that determine specimen delivery time and costs. 2. There is a wide variation in costs for toxicologic methods, which requires that an analysis of capital (equipment) purchase and operational (test performance) costs be performed to avoid waste, purchase wisely, and determine which tests consume the majority of the laboratory's resources. 3. Toxicologic analysis is composed of many complex steps. Each step must be individually cost-accounted. Screening test results must be confirmed, and the cost for both steps must be included in the cost per reportable result. 4. Total costs will vary in the same laboratory and between laboratories based on differences in salaries paid to technical staff, differences in reagent/supply costs, the number of technical staff needed to operate the analyzer or perform the method, and the inefficient use of highly paid staff to operate the analyzer or perform the method. 5. Since direct test costs vary directly with the type and number of analyzers or methods and are dependent on the operational mode designed by the manufacturer, laboratory managers should construct an actual test-cost data base for instrument or method in use to accurately compare costs using the "bottom-up" approach. 6. Laboratory expenses can be examined from three perspectives: total laboratory, laboratory section, and subsection workstation. The objective is to track all laboratory expenses through each of these levels. 7. In the final analysis, a portion of total laboratory expenses must be allocated to each unit of laboratory output--the billable procedure or, in laboratories where tests are not billed, the tests produced.(ABSTRACT TRUNCATED AT 400 WORDS)

  15. Test Analysis Guidelines

    NASA Technical Reports Server (NTRS)

    Jeng, Frank F.

    2007-01-01

    Development of analysis guidelines for Exploration Life Support (ELS) technology tests was completed. The guidelines were developed based on analysis experiences gained from supporting Environmental Control and Life Support System (ECLSS) technology development in air revitalization systems and water recovery systems. Analyses are vital during all three phases of the ELS technology test: pre-test, during test and post test. Pre-test analyses of a test system help define hardware components, predict system and component performances, required test duration, sampling frequencies of operation parameters, etc. Analyses conducted during tests could verify the consistency of all the measurements and the performance of the test system. Post test analyses are an essential part of the test task. Results of post test analyses are an important factor in judging whether the technology development is a successful one. In addition, development of a rigorous model for a test system is an important objective of any new technology development. Test data analyses, especially post test data analyses, serve to verify the model. Test analyses have supported development of many ECLSS technologies. Some test analysis tasks in ECLSS technology development are listed in the Appendix. To have effective analysis support for ECLSS technology tests, analysis guidelines would be a useful tool. These test guidelines were developed based on experiences gained through previous analysis support of various ECLSS technology tests. A comment on analysis from an experienced NASA ECLSS manager (1) follows: "Bad analysis was one that bent the test to prove that the analysis was right to begin with. Good analysis was one that directed where the testing should go and also bridged the gap between the reality of the test facility and what was expected on orbit."

  16. An effect size filter improves the reproducibility in spectral counting-based comparative proteomics.

    PubMed

    Gregori, Josep; Villarreal, Laura; Sánchez, Alex; Baselga, José; Villanueva, Josep

    2013-12-16

    The microarray community has shown that the low reproducibility observed in gene expression-based biomarker discovery studies is partially due to relying solely on p-values to get the lists of differentially expressed genes. Their conclusions recommended complementing the p-value cutoff with the use of effect-size criteria. The aim of this work was to evaluate the influence of such an effect-size filter on spectral counting-based comparative proteomic analysis. The results proved that the filter increased the number of true positives and decreased the number of false positives and the false discovery rate of the dataset. These results were confirmed by simulation experiments where the effect size filter was used to evaluate systematically variable fractions of differentially expressed proteins. Our results suggest that relaxing the p-value cut-off followed by a post-test filter based on effect size and signal level thresholds can increase the reproducibility of statistical results obtained in comparative proteomic analysis. Based on our work, we recommend using a filter consisting of a minimum absolute log2 fold change of 0.8 and a minimum signal of 2-4 SpC on the most abundant condition for the general practice of comparative proteomics. The implementation of feature filtering approaches could improve proteomic biomarker discovery initiatives by increasing the reproducibility of the results obtained among independent laboratories and MS platforms. Quality control analysis of microarray-based gene expression studies pointed out that the low reproducibility observed in the lists of differentially expressed genes could be partially attributed to the fact that these lists are generated relying solely on p-values. Our study has established that the implementation of an effect size post-test filter improves the statistical results of spectral count-based quantitative proteomics. The results proved that the filter increased the number of true positives whereas decreased the false positives and the false discovery rate of the datasets. The results presented here prove that a post-test filter applying a reasonable effect size and signal level thresholds helps to increase the reproducibility of statistical results in comparative proteomic analysis. Furthermore, the implementation of feature filtering approaches could improve proteomic biomarker discovery initiatives by increasing the reproducibility of results obtained among independent laboratories and MS platforms. This article is part of a Special Issue entitled: Standardization and Quality Control in Proteomics. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Instructional designing the STEM education model for fostering creative thinking abilities in physics laboratory environment classes

    NASA Astrophysics Data System (ADS)

    Chanthala, Chumpon; Santiboon, Toansakul; Ponkham, Kamon

    2018-01-01

    To investigate the effects of students' activity-based on learning approaching management through the STEM Education Instructional Model for fostering their creative thinking abilities of their learning achievements in physics laboratory classroom environments with the sample size consisted of 48 students at the 10th grade level in two classes in Mahasarakham University Demonstration School(Secondary Division) in Thailand. Students' creative thinking abilities were assessed with the with the 24-item GuilfordCreative Thinking Questionnaire (GCTQ). Students' perceptions of their physics classroom learning environments were obtained using the 35-item Physics Laboratory Environment Inventory (PLEI). Associations between students' learning achievements of their post-test assessment indicated that 26% of the coefficient predictive value (R2) of the variance in students' creative thinking abilities was attributable to their perceptions for the GCTQ. Students' learning outcomes of their post-test assessment, the R2value indicated that 35% of the variances for the PLEI, the R2value indicated that 63% of the variances for their creative thinking abilities were attributable to theiraffecting the activity-based on learning for fostering their creative thinking are provided.

  18. Interlaboratory comparability, bias, and precision for four laboratories measuring constituents in precipitation, November 1982-August 1983

    USGS Publications Warehouse

    Brooks, M.H.; Schroder, L.J.; Malo, B.A.

    1985-01-01

    Four laboratories were evaluated in their analysis of identical natural and simulated precipitation water samples. Interlaboratory comparability was evaluated using analysis of variance coupled with Duncan 's multiple range test, and linear-regression models describing the relations between individual laboratory analytical results for natural precipitation samples. Results of the statistical analyses indicate that certain pairs of laboratories produce different results when analyzing identical samples. Analyte bias for each laboratory was examined using analysis of variance coupled with Duncan 's multiple range test on data produced by the laboratories from the analysis of identical simulated precipitation samples. Bias for a given analyte produced by a single laboratory has been indicated when the laboratory mean for that analyte is shown to be significantly different from the mean for the most-probable analyte concentrations in the simulated precipitation samples. Ion-chromatographic methods for the determination of chloride, nitrate, and sulfate have been compared with the colorimetric methods that were also in use during the study period. Comparisons were made using analysis of variance coupled with Duncan 's multiple range test for means produced by the two methods. Analyte precision for each laboratory has been estimated by calculating a pooled variance for each analyte. Analyte estimated precisions have been compared using F-tests and differences in analyte precisions for laboratory pairs have been reported. (USGS)

  19. Digital versus conventional techniques for pattern fabrication of implant-supported frameworks

    PubMed Central

    Alikhasi, Marzieh; Rohanian, Ahmad; Ghodsi, Safoura; Kolde, Amin Mohammadpour

    2018-01-01

    Objective: The aim of this experimental study was to compare retention of frameworks cast from wax patterns fabricated by three different methods. Materials and Methods: Thirty-six implant analogs connected to one-piece abutments were divided randomly into three groups according to the wax pattern fabrication method (n = 12). Computer-aided design/computer-aided manufacturing (CAD/CAM) milling machine, three-dimensional printer, and conventional technique were used for fabrication of waxing patterns. All laboratory procedures were performed by an expert-reliable technician to eliminate intra-operator bias. The wax patterns were cast, finished, and seated on related abutment analogs. The number of adjustment times was recorded and analyzed by Kruskal–Wallis test. Frameworks were cemented on the corresponding analogs with zinc phosphate cement and tensile resistance test was used to measure retention value. Statistical Analysis Used: One-way analysis of variance (ANOVA) and post hoc Tukey tests were used for statistical analysis. Level of significance was set at P < 0.05. Results: The mean retentive values of 680.36 ± 21.93 N, 440.48 ± 85.98 N, and 407.23 ± 67.48 N were recorded for CAD/CAM, rapid prototyping, and conventional group, respectively. One-way ANOVA test revealed significant differences among the three groups (P < 0.001). The post hoc Tukey test showed significantly higher retention for CAD/CAM group (P < 0.001), while there was no significant difference between the two other groups (P = 0.54). CAD/CAM group required significantly more adjustments (P < 0.001). Conclusions: CAD/CAM-fabricated wax patterns showed significantly higher retention for implant-supported cement-retained frameworks; this could be a valuable help when there are limitations in the retention of single-unit implant restorations. PMID:29657528

  20. Survey of Clinical Laboratory Practices for 2015 Middle East Respiratory Syndrome Coronavirus Outbreak in the Republic of Korea.

    PubMed

    Lee, Mi-Kyung; Kim, Sinyoung; Kim, Mi-Na; Kweon, Oh Joo; Lim, Yong Kwan; Ki, Chang-Seok; Kim, Jae-Seok; Seong, Moon-Woo; Sung, Heungsup; Yong, Dongeun; Lee, Hyukmin; Choi, Jong-Rak; Kim, Jeong-Ho

    2016-03-01

    It is crucial to understand the current status of clinical laboratory practices for the largest outbreak of Middle East respiratory syndrome coronavirus (MERS-CoV) infections in the Republic of Korea to be well prepared for future emerging infectious diseases. We conducted a survey of 49 clinical laboratories in medical institutions and referral medical laboratories. A short questionnaire to survey clinical laboratory practices relating to MERS-CoV diagnostic testing was sent by email to the directors and clinical pathologists in charge of the clinical laboratories performing MERS-CoV testing. The survey focused on testing volume, reporting of results, resources, and laboratory safety. A total of 40 clinical laboratories responded to the survey. A total of 27,009 MERS-CoV real-time reverse transcription PCR (rRT-PCR) tests were performed. Most of the specimens were sputum (73.5%). The median turnaround time (TAT) was 5.29 hr (first and third quartile, 4.11 and 7.48 hr) in 26 medical institutions. The median TAT of more than a half of the laboratories (57.7%) was less than 6 hr. Many laboratories were able to perform tests throughout the whole week. Laboratory biosafety preparedness included class II biosafety cabinets (100%); separated pre-PCR, PCR, and post-PCR rooms (88.6%); negative pressure pretreatment rooms (48.6%); and negative pressure sputum collection rooms (20.0%). Clinical laboratories were able to quickly expand their diagnostic capacity in response to the 2015 MERS-CoV outbreak. Our results show that clinical laboratories play an important role in the maintenance and enhancement of laboratory response in preparation for future emerging infections.

  1. Survey of Clinical Laboratory Practices for 2015 Middle East Respiratory Syndrome Coronavirus Outbreak in the Republic of Korea

    PubMed Central

    Lee, Mi-Kyung; Kim, Sinyoung; Kim, Mi-Na; Kweon, Oh Joo; Lim, Yong Kwan; Ki, Chang-Seok; Kim, Jae-Seok; Seong, Moon-Woo; Sung, Heungsup; Yong, Dongeun; Lee, Hyukmin; Choi, Jong-Rak

    2016-01-01

    Background It is crucial to understand the current status of clinical laboratory practices for the largest outbreak of Middle East respiratory syndrome coronavirus (MERS-CoV) infections in the Republic of Korea to be well prepared for future emerging infectious diseases. Methods We conducted a survey of 49 clinical laboratories in medical institutions and referral medical laboratories. A short questionnaire to survey clinical laboratory practices relating to MERS-CoV diagnostic testing was sent by email to the directors and clinical pathologists in charge of the clinical laboratories performing MERS-CoV testing. The survey focused on testing volume, reporting of results, resources, and laboratory safety. Results A total of 40 clinical laboratories responded to the survey. A total of 27,009 MERS-CoV real-time reverse transcription PCR (rRT-PCR) tests were performed. Most of the specimens were sputum (73.5%). The median turnaround time (TAT) was 5.29 hr (first and third quartile, 4.11 and 7.48 hr) in 26 medical institutions. The median TAT of more than a half of the laboratories (57.7%) was less than 6 hr. Many laboratories were able to perform tests throughout the whole week. Laboratory biosafety preparedness included class II biosafety cabinets (100%); separated pre-PCR, PCR, and post-PCR rooms (88.6%); negative pressure pretreatment rooms (48.6%); and negative pressure sputum collection rooms (20.0%). Conclusions Clinical laboratories were able to quickly expand their diagnostic capacity in response to the 2015 MERS-CoV outbreak. Our results show that clinical laboratories play an important role in the maintenance and enhancement of laboratory response in preparation for future emerging infections. PMID:26709263

  2. 7 CFR 160.17 - Laboratory analysis.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Laboratory analysis. 160.17 Section 160.17 Agriculture... STANDARDS FOR NAVAL STORES Methods of Analysis, Inspection, Sampling and Grading § 160.17 Laboratory analysis. The analysis and laboratory testing of naval stores shall be conducted, so far as is practicable...

  3. 7 CFR 160.17 - Laboratory analysis.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory analysis. 160.17 Section 160.17 Agriculture... STANDARDS FOR NAVAL STORES Methods of Analysis, Inspection, Sampling and Grading § 160.17 Laboratory analysis. The analysis and laboratory testing of naval stores shall be conducted, so far as is practicable...

  4. Effect of a novel video game on stroke knowledge of 9- to 10-year-old, low-income children.

    PubMed

    Williams, Olajide; Hecht, Mindy F; DeSorbo, Alexandra L; Huq, Saima; Noble, James M

    2014-03-01

    Improving actionable stroke knowledge of a witness or bystander, which in some cases are children, may improve response to an acute stroke event. We used a quasiexperimental pre-test post-test design to evaluate actionable stroke knowledge of 210 children aged 9 to 10 years in response to a single, 15-minute exposure to a stroke education video game conducted in the school computer laboratory. After immediate post-test, we provided remote password-protected online video game access and encouraged children to play at their leisure from home. An unannounced delayed post-test occurred 7 weeks later. Two hundred ten children completed pretest, 205 completed immediate post-test, whereas 198 completed delayed post-test. One hundred fifty-six (74%) children had Internet access at home, and 41 (26%), mostly girls, played the video game remotely. There was significant improvement in stroke symptom composite scores, calling 911, and all individual stroke knowledge items, including a distractor across the testing sequence (P<0.05). Children who played the video game remotely demonstrated significant improvement in knowledge of 1 symptom (sudden imbalance) compared with children who did not (P<0.05), although overall composite scores showed no difference. Stroke education video games may represent novel means for improving and sustaining actionable stroke knowledge of children.

  5. Development and validation of an immunoperoxidase antigen detection test for improved diagnosis of rabies in Indonesia.

    PubMed

    Rahmadane, Ibnu; Certoma, Andrea F; Peck, Grantley R; Fitria, Yul; Payne, Jean; Colling, Axel; Shiell, Brian J; Beddome, Gary; Wilson, Susanne; Yu, Meng; Morrissy, Chris; Michalski, Wojtek P; Bingham, John; Gardner, Ian A; Allen, John D

    2017-11-01

    Rabies continues to pose a significant threat to human and animal health in regions of Indonesia. Indonesia has an extensive network of veterinary diagnostic laboratories and the 8 National laboratories are equipped to undertake diagnostic testing for rabies using the commercially-procured direct fluorescent antibody test (FAT), which is considered the reference (gold standard) test. However, many of the Indonesian Provincial diagnostic laboratories do not have a fluorescence microscope required to undertake the FAT. Instead, certain Provincial laboratories continue to screen samples using a chemical stain-based test (Seller's stain test, SST). This test has low diagnostic sensitivity, with negative SST-tested samples being forwarded to the nearest National laboratory resulting in significant delays for completion of testing and considerable additional costs. This study sought to develop a cost-effective and diagnostically-accurate immunoperoxidase antigen detection (RIAD) test for rabies that can be readily and quickly performed by the resource-constrained Provincial laboratories. This would reduce the burden on the National laboratories and allow more rapid diagnoses and implementation of post-exposure prophylaxis. The RIAD test was evaluated using brain smears fixed with acetone or formalin and its performance was validated by comparison with established rabies diagnostic tests used in Indonesia, including the SST and FAT. A proficiency testing panel was distributed between Provincial laboratories to assess the reproducibility of the test. The performance of the RIAD test was improved by using acetone fixation of brain smears rather than formalin fixation such that it was of equivalent accuracy to that of the World Organisation for Animal Health (OIE)-recommended FAT, with both tests returning median diagnostic sensitivity and specificity values of 0.989 and 0.993, respectively. The RIAD test and FAT had higher diagnostic sensitivity than the SST (median = 0.562). Proficiency testing using a panel of 6 coded samples distributed to 16 laboratories showed that the RIAD test had good reproducibility with an overall agreement of 97%. This study describes the successful development, characterisation and use of a novel RIAD test and its fitness for purpose as a screening test for use in provincial Indonesian veterinary laboratories.

  6. The Use of Graphing Technology to Promote Transfer of Learning: the Interpretation of Graphs in Physics.

    NASA Astrophysics Data System (ADS)

    Nichols, Jeri Ann

    This study examined the relationship between mathematics background and performance on graph-related problems in physics before and after instruction on the graphical analysis of motion and several microcomputer-based laboratory experiences. Students identified as either having or not having a graphing technology enhanced precalculus mathematics background were further categorized into one of four groups according to mathematics placement at the university. The performances of these groups were compared to identity differences. Pre- and Post-test data were collected from 589 students and 312 students during Autumn Quarter 1990 and Winter Quarter 1991 respectively. Background information was collected from each student. Significant differences were found between students with the technology enhanced mathematics background and those without when considering the entire populations both quarters. The students with the technology background were favored Autumn quarter and students without the technology background were favored Winter quarter. However, the entire population included an underrepresentation of students at the highest and lowest placements; hence, these were eliminated from the analyses. No significant differences were found between the technology/no technology groups after the elimination of the underrepresented groups. All categories of students increased their mean scores from pretest to post-test; the average increase was 8.23 points Autumn Quarter and 11.41 points Winter Quarter. Males consistently outperformed females on both the pretest and the post-test Autumn 1990. All students found questions involving the concept of acceleration more difficult than questions involving velocity or distance. Questions requiring students to create graphs were more difficult than questions requiring students to interpret graphs. Further research involving a qualitative component is recommended to identify the specific skills students use when solving graph-related physics problems. In addition, it is recommended that a similar study be conducted to include a control group not participating in the microcomputer -based laboratory experiments.

  7. One simple DNA extraction device and its combination with modified visual loop-mediated isothermal amplification for rapid on-field detection of genetically modified organisms.

    PubMed

    Zhang, Miao; Liu, Yinan; Chen, Lili; Quan, Sheng; Jiang, Shimeng; Zhang, Dabing; Yang, Litao

    2013-01-02

    Quickness, simplicity, and effectiveness are the three major criteria for establishing a good molecular diagnosis method in many fields. Herein we report a novel detection system for genetically modified organisms (GMOs), which can be utilized to perform both on-field quick screening and routine laboratory diagnosis. In this system, a newly designed inexpensive DNA extraction device was used in combination with a modified visual loop-mediated isothermal amplification (vLAMP) assay. The main parts of the DNA extraction device included a silica gel membrane filtration column and a modified syringe. The DNA extraction device could be easily operated without using other laboratory instruments, making it applicable to an on-field GMO test. High-quality genomic DNA (gDNA) suitable for polymerase chain reaction (PCR) and isothermal amplification could be quickly isolated from plant tissues using this device within 15 min. In the modified vLAMP assay, a microcrystalline wax encapsulated detection bead containing SYBR green fluorescent dye was introduced to avoid dye inhibition and cross-contaminations from post-LAMP operation. The system was successfully applied and validated in screening and identification of GM rice, soybean, and maize samples collected from both field testing and the Grain Inspection, Packers, and Stockyards Administration (GIPSA) proficiency test program, which demonstrated that it was well-adapted to both on-field testing and/or routine laboratory analysis of GMOs.

  8. Cortisol responses to naturalistic and laboratory stress in student teachers: comparison with a non-stress control day.

    PubMed

    Wolfram, Maren; Bellingrath, Silja; Feuerhahn, Nicolas; Kudielka, Brigitte M

    2013-04-01

    Ambulatory assessments of hypothalamus-pituitary-adrenal axis responses to acute natural stressors yield evidence on stress regulation with high ecological validity. Sampling of salivary cortisol is a standard technique in this field. In 21 healthy student teachers, we assessed cortisol responses to a demonstration lesson. On a control day, sampling was repeated at analogous times. Additionally, the cortisol awakening response (CAR) was assessed on both days. Participants were also exposed to a laboratory stressor, the Trier Social Stress Test, and rated their individual levels of chronic work stress. In pre-to-post-stress assessment, cortisol levels declined after the lesson. However, post-stress cortisol levels were significantly higher compared with those on the control day. Also, the Trier Social Stress Test yielded higher cortisol responses when using the control day as reference baseline. Associations between the CAR and chronic stress measures were observed solely on the control day. There were no significant associations between cortisol responses to the natural and laboratory stressors. Our results indicate that a control day might be an important complement in laboratory but especially in ambulatory stress research. Furthermore, associations between chronic stress measures and the CAR might be obscured by acute stress exposure. Finally, responses to the laboratory stressor do not seem to mirror natural stress responses. Copyright © 2012 John Wiley & Sons, Ltd.

  9. Estimating rotavirus gastroenteritis hospitalisations by using hospital episode statistics before and after the introduction of rotavirus vaccine in Australia.

    PubMed

    Jayasinghe, Sanjay; Macartney, Kristine

    2013-01-30

    Hospital discharge records and laboratory data have shown a substantial early impact from the rotavirus vaccination program that commenced in 2007 in Australia. However, these assessments are affected by the validity and reliability of hospital discharge coding and stool testing to measure the true incidence of hospitalised disease. The aim of this study was to assess the validity of these data sources for disease estimation, both before and after, vaccine introduction. All hospitalisations at a major paediatric centre in children aged <5 years from 2000 to 2009 containing acute gastroenteritis (AGE) ICD 10 AM diagnosis codes were linked to hospital laboratory stool testing data. The validity of the rotavirus-specific diagnosis code (A08.0) and the incidence of hospitalisations attributable to rotavirus by both direct estimation and with adjustments for non-testing and miscoding were calculated for pre- and post-vaccination periods. A laboratory record of stool testing was available for 36% of all AGE hospitalisations (n=4948) the rotavirus code had high specificity (98.4%; 95% CI, 97.5-99.1%) and positive predictive value (96.8%; 94.8-98.3%), and modest sensitivity (61.6%; 58-65.1%). Of all rotavirus test positive hospitalisations only a third had a rotavirus code. The estimated annual average number of rotavirus hospitalisations, following adjustment for non-testing and miscoding was 5- and 6-fold higher than identified, respectively, from testing and coding alone. Direct and adjusted estimates yielded similar percentage reductions in annual average rotavirus hospitalisations of over 65%. Due to the limited use of stool testing and poor sensitivity of the rotavirus-specific diagnosis code routine hospital discharge and laboratory data substantially underestimate the true incidence of rotavirus hospitalisations and absolute vaccine impact. However, this data can still be used to monitor vaccine impact as the effects of miscoding and under-testing appear to be comparable between pre and post vaccination periods. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Laboratory-acquired infections of Salmonella enterica serotype Typhi in South Africa: phenotypic and genotypic analysis of isolates.

    PubMed

    Smith, Anthony Marius; Smouse, Shannon Lucrecia; Tau, Nomsa Pauline; Bamford, Colleen; Moodley, Vineshree Mischka; Jacobs, Charlene; McCarthy, Kerrigan Mary; Lourens, Adré; Keddy, Karen Helena

    2017-09-29

    Workers in clinical microbiology laboratories are exposed to a variety of pathogenic microorganisms. Salmonella species is among the most commonly reported bacterial causes of laboratory-acquired infections. We report on three cases of laboratory-acquired Salmonella enterica serotype Typhi (Salmonella Typhi) infection which occurred over the period 2012 to 2016 in South Africa. Laboratory investigation included phenotypic and genotypic characterization of isolates. Phenotypic analysis included standard microbiological identification techniques, serotyping and antimicrobial susceptibility testing. Genotypic analysis included the molecular subtyping methodologies of pulsed-field gel electrophoresis analysis, multilocus sequence typing and whole-genome sequencing (WGS); with WGS data analysis including phylogenetic analysis based upon comparison of single nucleotide polymorphism profiles of isolates. All cases of laboratory-acquired infection were most likely the result of lapses in good laboratory practice and laboratory safety. The following critical issues were highlighted. There was misdiagnosis and misreporting of Salmonella Typhi as nontyphoidal Salmonella by a diagnostic laboratory, with associated public health implications. We highlight issues concerning the importance of accurate fluoroquinolone susceptibility testing and interpretation of results according to updated guidelines. We describe potential shortcomings of a single disk susceptibility screening test for fluoroquinolone susceptibility and suggest that confirmatory minimum inhibitory concentration testing should always be performed in cases of invasive Salmonella infections. These antimicrobial susceptibility testing issues resulted in inappropriate ciprofloxacin therapy which may have been responsible for failure in clearance of pathogen from patients. Salmonella Typhi capsular polysaccharide vaccine was not protective in one case, possibly secondarily to a faulty vaccine. Molecular subtyping of isolates proved effective to investigate the genetic relatedness of isolates. Molecular subtyping data interpreted together with epidemiological data allowed us to pinpoint the most likely sources for our cases of laboratory-acquired infection.

  11. Program documentation for the space environment test division post-test data reduction program (GNFLEX)

    NASA Technical Reports Server (NTRS)

    Jones, L. D.

    1979-01-01

    The Space Environment Test Division Post-Test Data Reduction Program processes data from test history tapes generated on the Flexible Data System in the Space Environment Simulation Laboratory at the National Aeronautics and Space Administration/Lyndon B. Johnson Space Center. The program reads the tape's data base records to retrieve the item directory conversion file, the item capture file and the process link file to determine the active parameters. The desired parameter names are read in by lead cards after which the periodic data records are read to determine parameter data level changes. The data is considered to be compressed rather than full sample rate. Tabulations and/or a tape for generating plots may be output.

  12. Integrity assessment of grouted posttensioning cables and reinforced concrete of a nuclear containment building

    NASA Astrophysics Data System (ADS)

    Philipose, K.; Shenton, B.

    2011-04-01

    The Containment Buildings of CANDU Nuclear Generating Stations were designed to house nuclear reactors and process equipment and also to provide confinement of releases from a potential nuclear accident such as a Loss Of Coolant Accident (LOCA). To meet this design requirement, a post-tensioning system was designed to induce compressive stresses in the structure to counteract the internal design pressure. The CANDU reactor building at Gentilly-1 (G-1), Quebec, Canada (250 MWe) was built in the early 1970s and is currently in a decommissioned state. The structure at present is under surveillance and monitoring. In the year 2000, a field investigation was conducted as part of a condition assessment and corrosion was detected in some of the grouted post-tension cable strands. However, no further work was done at that time to determine the cause, nature, impact and extent of the corrosion. An investigation of the Gentilly-1 containment building is currently underway to assess the condition of grouted post-tensioning cables and reinforced concrete. At two selected locations, concrete and steel reinforcements were removed from the containment building wall to expose horizontal cables. Individual cable strands and reinforcement bars were instrumented and measurements were taken in-situ before removing them for forensic examination and destructive testing to determine the impact of ageing and corrosion. Concrete samples were also removed and tested in a laboratory. The purpose of the field investigation and laboratory testing, using this structure as a test bed, was also to collect material ageing data and to develop potential Nondestructive Examination (NDE) methods to monitor Containment Building Integrity. The paper describes the field work conducted and the test results obtained for concrete, reinforcement and post-tensioning cables.

  13. Genetic structure among coastal tailed frog populations of Mount St. Helens is moderated by post-disturbance management

    Treesearch

    Stephen F. Spear; Charles M. Crisafulli; Andrew Storfer

    2012-01-01

    Catastrophic disturbances often provide “natural laboratories” that allow for greater understanding of ecological processes and response of natural populations. The 1980 eruption of the Mount St. Helens volcano in Washington, USA, provided a unique opportunity to test biotic effects of a large-scale stochastic disturbance, as well as the influence of post-disturbance...

  14. Utility of repeat testing of critical values: a Q-probes analysis of 86 clinical laboratories.

    PubMed

    Lehman, Christopher M; Howanitz, Peter J; Souers, Rhona; Karcher, Donald S

    2014-06-01

    A common laboratory practice is to repeat critical values before reporting the test results to the clinical care provider. This may be an unnecessary step that delays the reporting of critical test results without adding value to the accuracy of the test result. To determine the proportions of repeated chemistry and hematology critical values that differ significantly from the original value as defined by the participating laboratory, to determine the threshold differences defined by the laboratory as clinically significant, and to determine the additional time required to analyze the repeat test. Participants prospectively reviewed critical test results for 4 laboratory tests: glucose, potassium, white blood cell count, and platelet count. Participants reported the following information: initial and repeated test result; time initial and repeat results were first known to laboratory staff; critical result notification time; if the repeat result was still a critical result; if the repeat result was significantly different from the initial result, as judged by the laboratory professional or policy; significant difference threshold, as defined by the laboratory; the make and model of the instrument used for primary and repeat testing. Routine, repeat analysis of critical values is a common practice. Most laboratories did not formally define a significant difference between repeat results. Repeated results were rarely considered significantly different. Median repeated times were at least 17 to 21 minutes for 10% of laboratories. Twenty percent of laboratories reported at least 1 incident in the last calendar year of delayed result reporting that clinicians indicated had adversely affected patient care. Routine repeat analysis of automated chemistry and hematology critical values is unlikely to be clinically useful and may adversely affect patient care.

  15. Effect of Metformin and Flutamide on Anthropometric Indices and Laboratory Tests in Obese/Overweight PCOS Women under Hypocaloric Diet

    PubMed Central

    Amiri, Mania; Golsorkhtabaramiri, Masoumeh; Esmaeilzadeh, Sedigheh; Ghofrani, Faeze; Bijani, Ali; Ghorbani, Leila; Delavar, Moloud Agajani

    2014-01-01

    Background This study was designed to investigate the effect of metformin and flutamide alone or in combination with anthropometric indices and laboratory tests of obese/overweight PCOS women under hypocaloric diet. Methods This single blind clinical trial was performed on 120 PCOS women. At the beginning, hypocaloric diet was recommended for the patients. After one month while they were on the diet, the patients were randomly divided in 4 groups; metformin (500 mg, 3/day), flutamide (250 mg, 2/day), combined, metformin (500 mg, 3/day) with flutamide (250 mg, 2/day) and finally placebo group. The patients were treated for 6 months. Anthropometric indices and laboratory tests (fasting and glucose-stimulated insulin levels, lipid profile and androgens) were measured. A one-way ANOVA (Post Hoc) and paired t-test were performed to analyze data. A p ≤ 0.05 was considered statistically significant. Results After treatment, reduction in weight, BMI, hip circumference was significantly greater in the metformin group in comparison to other groups (p<0.05). In addition, the fasting insulin was significantly greater in metformin group and flutamide group in comparison to metformin+flutamide and placebo groups after treatment (p<0.05). Within groups, insulin level showed significant changes (before and after treatment) in metformin+flutamide group and LDL reduction was significant in flutamide group before and after treatment. Post hoc tukey and two-tailed with p≤0.05 were used to define statistical significance. Conclusion Using combination of metformin and flutamide improves anthropometric indices and laboratory tests in obese/overweight PCOS women under hypocaloric diet. PMID:25473629

  16. Electronic medical records and efficiency and productivity during office visits.

    PubMed

    Furukawa, Michael F

    2011-04-01

    To estimate the relationship between electronic medical record (EMR) use and efficiency of utilization and provider productivity during visits to US office-based physicians. Cross-sectional analysis of the 2006-2007 National Ambulatory Medical Care Survey. The sample included 62,710 patient visits to 2625 physicians. EMR systems included demographics, clinical notes, prescription orders, and laboratory and imaging results. Efficiency was measured as utilization of examinations, laboratory tests, radiology procedures, health education, nonmedication treatments, and medications. Productivity was measured as total services provided per 20-minute period. Survey-weighted regressions estimated association of EMR use with services provided, visit intensity/duration, and productivity. Marginal effects were estimated by averaging across all visits and by major reason for visit. EMR use was associated with higher probability of any examination (7.7%, 95% confidence interval [CI] = 2.4%, 13.1%); any laboratory test (5.7%, 95% CI = 2.6%, 8.8%); any health education (4.9%, 95% CI = 0.2%, 9.6%); and fewer laboratory tests (-7.1%, 95% CI = -14.2%, -0.1%). During pre/post surgery visits, EMR use was associated with 7.3% (95% CI= -12.9%, -1.8%) fewer radiology procedures. EMR use was not associated with utilization of nonmedication treatments and medications, or visit duration. During routine visits for a chronic problem, EMR use was associated with 11.2% (95% CI = 5.7%, 16.8%) more diagnostic/screening services provided per 20-minute period. EMR use had a mixed association with efficiency and productivity during office visits. EMRs may improve provider productivity, especially during visits for a new problem and routine chronic care.

  17. Development of a Radial Deconsolidation Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helmreich, Grant W.; Montgomery, Fred C.; Hunn, John D.

    2015-12-01

    A series of experiments have been initiated to determine the retention or mobility of fission products* in AGR fuel compacts [Petti, et al. 2010]. This information is needed to refine fission product transport models. The AGR-3/4 irradiation test involved half-inch-long compacts that each contained twenty designed-to-fail (DTF) particles, with 20-μm thick carbon-coated kernels whose coatings were deliberately fabricated such that they would crack under irradiation, providing a known source of post-irradiation isotopes. The DTF particles in these compacts were axially distributed along the compact centerline so that the diffusion of fission products released from the DTF kernels would be radiallymore » symmetric [Hunn, et al. 2012; Hunn et al. 2011; Kercher, et al. 2011; Hunn, et al. 2007]. Compacts containing DTF particles were irradiated at Idaho National Laboratory (INL) at the Advanced Test Reactor (ATR) [Collin, 2015]. Analysis of the diffusion of these various post-irradiation isotopes through the compact requires a method to radially deconsolidate the compacts so that nested-annular volumes may be analyzed for post-irradiation isotope inventory in the compact matrix, TRISO outer pyrolytic carbon (OPyC), and DTF kernels. An effective radial deconsolidation method and apparatus appropriate to this application has been developed and parametrically characterized.« less

  18. Field scale test of multi-dimensional flow and morphodynamic simulations used for restoration design analysis

    USGS Publications Warehouse

    McDonald, Richard R.; Nelson, Jonathan M.; Fosness, Ryan L.; Nelson, Peter O.; Constantinescu, George; Garcia, Marcelo H.; Hanes, Dan

    2016-01-01

    Two- and three-dimensional morphodynamic simulations are becoming common in studies of channel form and process. The performance of these simulations are often validated against measurements from laboratory studies. Collecting channel change information in natural settings for model validation is difficult because it can be expensive and under most channel forming flows the resulting channel change is generally small. Several channel restoration projects designed in part to armor large meanders with several large spurs constructed of wooden piles on the Kootenai River, ID, have resulted in rapid bed elevation change following construction. Monitoring of these restoration projects includes post- restoration (as-built) Digital Elevation Models (DEMs) as well as additional channel surveys following high channel forming flows post-construction. The resulting sequence of measured bathymetry provides excellent validation data for morphodynamic simulations at the reach scale of a real river. In this paper we test the performance a quasi-three-dimensional morphodynamic simulation against the measured elevation change. The resulting simulations predict the pattern of channel change reasonably well but many of the details such as the maximum scour are under predicted.

  19. Empirical Model for Predicting Rockfall Trajectory Direction

    NASA Astrophysics Data System (ADS)

    Asteriou, Pavlos; Tsiambaos, George

    2016-03-01

    A methodology for the experimental investigation of rockfall in three-dimensional space is presented in this paper, aiming to assist on-going research of the complexity of a block's response to impact during a rockfall. An extended laboratory investigation was conducted, consisting of 590 tests with cubical and spherical blocks made of an artificial material. The effects of shape, slope angle and the deviation of the post-impact trajectory are examined as a function of the pre-impact trajectory direction. Additionally, an empirical model is proposed that estimates the deviation of the post-impact trajectory as a function of the pre-impact trajectory with respect to the slope surface and the slope angle. This empirical model is validated by 192 small-scale field tests, which are also presented in this paper. Some important aspects of the three-dimensional nature of rockfall phenomena are highlighted that have been hitherto neglected. The 3D space data provided in this study are suitable for the calibration and verification of rockfall analysis software that has become increasingly popular in design practice.

  20. Assessment of vaccine testing at three laboratories using the guinea pig model of tuberculosis.

    PubMed

    Grover, Ajay; Troudt, Jolynn; Arnett, Kimberly; Izzo, Linda; Lucas, Megan; Strain, Katie; McFarland, Christine; Hall, Yper; McMurray, David; Williams, Ann; Dobos, Karen; Izzo, Angelo

    2012-01-01

    The guinea pig model of tuberculosis is used extensively in different locations to assess the efficacy of novel tuberculosis vaccines during pre-clinical development. Two key assays are used to measure protection against virulent challenge: a 30 day post-infection assessment of mycobacterial burden and long-term post-infection survival and pathology analysis. To determine the consistency and robustness of the guinea pig model for testing vaccines, a comparative assessment between three sites that are currently involved in testing tuberculosis vaccines from external providers was performed. Each site was asked to test two "subunit" type vaccines in their routine animal model as if testing vaccines from a provider. All sites performed a 30 day study, and one site also performed a long-term survival/pathology study. Despite some differences in experimental approach between the sites, such as the origin of the Mycobacterium tuberculosis strain and the type of aerosol exposure device used to infect the animals and the source of the guinea pigs, the data obtained between sites were consistent in regard to the ability of each "vaccine" tested to reduce the mycobacterial burden. The observations also showed that there was good concurrence between the results of short-term and long-term studies. This validation exercise means that efficacy data can be compared between sites. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. A Post-Processing Receiver for the Lunar Laser Communications Demonstration Project

    NASA Technical Reports Server (NTRS)

    Srinivasan, Meera; Birnbaum, Kevin; Cheng, Michael; Quirk, Kevin

    2013-01-01

    The Lunar Laser Communications Demonstration Project undertaken by MIT Lincoln Laboratory and NASA's Goddard Space Flight Center will demonstrate high-rate laser communications from lunar orbit to the Earth. NASA's Jet Propulsion Laboratory is developing a backup ground station supporting a data rate of 39 Mbps that is based on a non-real-time software post-processing receiver architecture. This approach entails processing sample-rate-limited data without feedback in the presence high uncertainty in downlink clock characteristics under low signal flux conditions. In this paper we present a receiver concept that addresses these challenges with descriptions of the photodetector assembly, sample acquisition and recording platform, and signal processing approach. End-to-end coded simulation and laboratory data analysis results are presented that validate the receiver conceptual design.

  2. ABR - Home

    Science.gov Websites

    Argonne National Laboratory Applied Battery Research for Transportation Program DOE Logo Home ; ABR > About ABR Projects News cell fabrication faciity posttest facility MERF Cell Fabrication Facility Post-Test Facility Materials Engineering Research Facility Battery News Recent Reports Funding

  3. Finite Element Analysis and Test Correlation of a 10-Meter Inflation-Deployed Solar Sail

    NASA Technical Reports Server (NTRS)

    Sleight, David W.; Michii, Yuki; Lichodziejewski, David; Derbes, Billy; Mann. Troy O.; Slade, Kara N.; Wang, John T.

    2005-01-01

    Under the direction of the NASA In-Space Propulsion Technology Office, the team of L Garde, NASA Jet Propulsion Laboratory, Ball Aerospace, and NASA Langley Research Center has been developing a scalable solar sail configuration to address NASA's future space propulsion needs. Prior to a flight experiment of a full-scale solar sail, a comprehensive phased test plan is currently being implemented to advance the technology readiness level of the solar sail design. These tests consist of solar sail component, subsystem, and sub-scale system ground tests that simulate the vacuum and thermal conditions of the space environment. Recently, two solar sail test articles, a 7.4-m beam assembly subsystem test article and a 10-m four-quadrant solar sail system test article, were tested in vacuum conditions with a gravity-offload system to mitigate the effects of gravity. This paper presents the structural analyses simulating the ground tests and the correlation of the analyses with the test results. For programmatic risk reduction, a two-prong analysis approach was undertaken in which two separate teams independently developed computational models of the solar sail test articles using the finite element analysis software packages: NEiNastran and ABAQUS. This paper compares the pre-test and post-test analysis predictions from both software packages with the test data including load-deflection curves from static load tests, and vibration frequencies and mode shapes from vibration tests. The analysis predictions were in reasonable agreement with the test data. Factors that precluded better correlation of the analyses and the tests were uncertainties in the material properties, test conditions, and modeling assumptions used in the analyses.

  4. Multiple comparison analysis testing in ANOVA.

    PubMed

    McHugh, Mary L

    2011-01-01

    The Analysis of Variance (ANOVA) test has long been an important tool for researchers conducting studies on multiple experimental groups and one or more control groups. However, ANOVA cannot provide detailed information on differences among the various study groups, or on complex combinations of study groups. To fully understand group differences in an ANOVA, researchers must conduct tests of the differences between particular pairs of experimental and control groups. Tests conducted on subsets of data tested previously in another analysis are called post hoc tests. A class of post hoc tests that provide this type of detailed information for ANOVA results are called "multiple comparison analysis" tests. The most commonly used multiple comparison analysis statistics include the following tests: Tukey, Newman-Keuls, Scheffee, Bonferroni and Dunnett. These statistical tools each have specific uses, advantages and disadvantages. Some are best used for testing theory while others are useful in generating new theory. Selection of the appropriate post hoc test will provide researchers with the most detailed information while limiting Type 1 errors due to alpha inflation.

  5. Analysis of Phenix end-of-life natural convection test with the MARS-LMR code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeong, H. Y.; Ha, K. S.; Lee, K. L.

    The end-of-life test of Phenix reactor performed by the CEA provided an opportunity to have reliable and valuable test data for the validation and verification of a SFR system analysis code. KAERI joined this international program for the analysis of Phenix end-of-life natural circulation test coordinated by the IAEA from 2008. The main objectives of this study were to evaluate the capability of existing SFR system analysis code MARS-LMR and to identify any limitation of the code. The analysis was performed in three stages: pre-test analysis, blind posttest analysis, and final post-test analysis. In the pre-test analysis, the design conditionsmore » provided by the CEA were used to obtain a prediction of the test. The blind post-test analysis was based on the test conditions measured during the tests but the test results were not provided from the CEA. The final post-test analysis was performed to predict the test results as accurate as possible by improving the previous modeling of the test. Based on the pre-test analysis and blind test analysis, the modeling for heat structures in the hot pool and cold pool, steel structures in the core, heat loss from roof and vessel, and the flow path at core outlet were reinforced in the final analysis. The results of the final post-test analysis could be characterized into three different phases. In the early phase, the MARS-LMR simulated the heat-up process correctly due to the enhanced heat structure modeling. In the mid phase before the opening of SG casing, the code reproduced the decrease of core outlet temperature successfully. Finally, in the later phase the increase of heat removal by the opening of the SG opening was well predicted with the MARS-LMR code. (authors)« less

  6. Post-irradiation-examination of irradiated fuel outside the hot cell

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dawn E. Janney; Adam B. Robinson; Thomas P. O'Holleran

    Because of their high radioactivity, irradiated fuels are commonly examined in a hot cell. However, the Idaho National Laboratory (INL) has recently investigated irradiated U-Mo-Al metallic fuel from the Reduced Enrichment for Research and Test Reactors (RERTR) project using a conventional unshielded scanning electron microscope outside a hot cell. This examination was possible because of a two-step sample-preparation approach in which a small volume of fuel was isolated in a hot cell and shielding was introduced during later stages of sample preparation. The resulting sample contained numerous sample-preparation artifacts but allowed analysis of microstructures from selected areas.

  7. Structural Analysis of an Inflation-Deployed Solar Sail With Experimental Validation

    NASA Technical Reports Server (NTRS)

    Sleight, David W.; Michii, Yuki; Lichodziejewski, David; Derbes, Billy; Mann, Troy O.

    2005-01-01

    Under the direction of the NASA In-Space Propulsion Technology Office, the team of L Garde, NASA Jet Propulsion Laboratory, Ball Aerospace, and NASA Langley Research Center has been developing a scalable solar sail configuration to address NASA s future space propulsion needs. Prior to a flight experiment of a full-scale solar sail, a comprehensive phased test plan is currently being implemented to advance the technology readiness level of the solar sail design. These tests consist of solar sail component, subsystem, and sub-scale system ground tests that simulate the vacuum and thermal conditions of the space environment. Recently, two solar sail test articles, a 7.4-m beam assembly subsystem test article and a 10-m four-quadrant solar sail system test article, were tested in vacuum conditions with a gravity-offload system to mitigate the effects of gravity. This paper presents the structural analyses simulating the ground tests and the correlation of the analyses with the test results. For programmatic risk reduction, a two-prong analysis approach was undertaken in which two separate teams independently developed computational models of the solar sail test articles using the finite element analysis software packages: NEiNastran and ABAQUS. This paper compares the pre-test and post-test analysis predictions from both software packages with the test data including load-deflection curves from static load tests, and vibration frequencies and mode shapes from structural dynamics tests. The analysis predictions were in reasonable agreement with the test data. Factors that precluded better correlation of the analyses and the tests were uncertainties in the material properties, test conditions, and modeling assumptions used in the analyses.

  8. Knowledge, attitude, and practice (KAP) of 'teaching laboratory' technicians towards laboratory safety and waste management: a pilot interventional study.

    PubMed

    El-Gilany, A-H; El-Shaer, S; Khashaba, E; El-Dakroory, S A; Omar, N

    2017-06-01

    A quasi-experimental study was performed on 20 technicians working in the Faculty of Medicine, Mansoura University, Egypt. The knowledge, attitude, and practice (KAP) of laboratory technicians was measured before and two months after enrolling them in an intervention programme about laboratory best practice procedures. The programme addressed laboratory safety and medical waste management. The assessment was performed using a validated Arabic self-administered questionnaire. Pre- and post-intervention scores were compared using non-parametric tests. There are significant increases in the scores of KAP after implementation of the training programme. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  9. Laboratory errors and patient safety.

    PubMed

    Miligy, Dawlat A

    2015-01-01

    Laboratory data are extensively used in medical practice; consequently, laboratory errors have a tremendous impact on patient safety. Therefore, programs designed to identify and reduce laboratory errors, as well as, setting specific strategies are required to minimize these errors and improve patient safety. The purpose of this paper is to identify part of the commonly encountered laboratory errors throughout our practice in laboratory work, their hazards on patient health care and some measures and recommendations to minimize or to eliminate these errors. Recording the encountered laboratory errors during May 2008 and their statistical evaluation (using simple percent distribution) have been done in the department of laboratory of one of the private hospitals in Egypt. Errors have been classified according to the laboratory phases and according to their implication on patient health. Data obtained out of 1,600 testing procedure revealed that the total number of encountered errors is 14 tests (0.87 percent of total testing procedures). Most of the encountered errors lay in the pre- and post-analytic phases of testing cycle (representing 35.7 and 50 percent, respectively, of total errors). While the number of test errors encountered in the analytic phase represented only 14.3 percent of total errors. About 85.7 percent of total errors were of non-significant implication on patients health being detected before test reports have been submitted to the patients. On the other hand, the number of test errors that have been already submitted to patients and reach the physician represented 14.3 percent of total errors. Only 7.1 percent of the errors could have an impact on patient diagnosis. The findings of this study were concomitant with those published from the USA and other countries. This proves that laboratory problems are universal and need general standardization and bench marking measures. Original being the first data published from Arabic countries that evaluated the encountered laboratory errors and launch the great need for universal standardization and bench marking measures to control the laboratory work.

  10. Technology to improve quality and accountability.

    PubMed

    Kay, Jonathan

    2006-01-01

    A body of evidence has been accumulated to demonstrate that current practice is not sufficiently safe for several stages of central laboratory testing. In particular, while analytical and perianalytical steps that take place within the laboratory are subjected to quality control procedures, this is not the case for several pre- and post-analytical steps. The ubiquitous application of auto-identification technology seems to represent a valuable tool for reducing error rates. A series of projects in Oxford has attempted to improve processes which support several areas of laboratory medicine, including point-of-care testing, blood transfusion, delivery and interpretation of reports, and support of decision-making by clinicians. The key tools are auto-identification, Internet communication technology, process re-engineering, and knowledge management.

  11. Safety of laboratory analyzers for infection testing - results of the market surveillance by the BfArM until end 2007

    PubMed Central

    2009-01-01

    The European Directive 98/79/EC on in vitro diagnostic medical devices (IVD) stipulates the marketing and post market surveillance of IVD in the European Economic Area. In cases of issues and field corrective actions, the manufacturers have to inform the responsible Competent Authorities (CA). In Germany, the Federal Institute for Drugs and Medical Devices (BfArM) is the responsible CA for most IVD, with a small subset of IVD for immune hematological and infectiological testing as well as tissue typing as specified in Annex II of the Directive, being within the responsibility of the Paul-Ehrlich-Institute (PEI). In this study, all issues regarding laboratory analyzers for infection testing and their consumables, but not reagents, kits and general culture media, reported to the BfArM between begin 1999 and end of 2007 were analyzed in respect to the sources of report, the underlying product failure and the performed corrective actions. Within the observation period a total of 1471 reports for IVD were received of which 73 related to the IVD for infection testing were included in our study. Reports were predominantly received from manufacturers (56) and competent authorities (15). Affected products were most frequently those for immunological analysis (42) whereas those based on culturing techniques (17) and molecular biological techniques (14) played only minor roles. In all these groups, laboratory analyzers (55) were more frequently affected than their consumables (18). Investigations of the manufacturers were able to identify the underlying root causes of product failures in 62 cases (84.9%). In 2 cases (2.7%) the root cause remained unclear and in 9 cases (12.3%) a product failure was excluded or a user error was the underlying cause. Product failures in laboratory analyzers were most frequently caused by software errors (31) and constructional faults (8) whereas the predominant cause of product failure in consumables were errors in production and quality control (8). Manufacturers issued corrective measures in 66 cases (90.4%) from which 49 and 17 were related to laboratory analyzers and their consumables, respectively. Based on the underlying root causes of product failures these were predominantly customer information (48), recalls (40), software-updates (30) and design changes (9) in the product group of laboratory analyzers as well as customer information (16), recalls (12) and modifications of production and quality management (11) in the group of consumables. The results and experiences obtained since 1999 suggest that the system for post marketing surveillance of IVD is an established tool to ensure product safety, even though the current system can be further enhanced. PMID:20156760

  12. Analysis and Test Support for Phillips Laboratory Precision Structures

    DTIC Science & Technology

    1998-11-01

    Air Force Research Laboratory ( AFRL ), Phillips Research Site . Task objectives centered...around analysis and structural dynamic test support on experiments within the Space Vehicles Directorate at Kirtland Air Force Base. These efforts help...support for Phillips Laboratory Precision Structures." Mr. James Goodding of CSA Engineering was the principal investigator for this task. Mr.

  13. Knowledge assistant: A sensor fusion framework for robotic environmental characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feddema, J.T.; Rivera, J.J.; Tucker, S.D.

    1996-12-01

    A prototype sensor fusion framework called the {open_quotes}Knowledge Assistant{close_quotes} has been developed and tested on a gantry robot at Sandia National Laboratories. This Knowledge Assistant guides the robot operator during the planning, execution, and post analysis stages of the characterization process. During the planning stage, the Knowledge Assistant suggests robot paths and speeds based on knowledge of sensors available and their physical characteristics. During execution, the Knowledge Assistant coordinates the collection of data through a data acquisition {open_quotes}specialist.{close_quotes} During execution and post analysis, the Knowledge Assistant sends raw data to other {open_quotes}specialists,{close_quotes} which include statistical pattern recognition software, a neuralmore » network, and model-based search software. After the specialists return their results, the Knowledge Assistant consolidates the information and returns a report to the robot control system where the sensed objects and their attributes (e.g. estimated dimensions, weight, material composition, etc.) are displayed in the world model. This paper highlights the major components of this system.« less

  14. An analysis of post-event processing in social anxiety disorder.

    PubMed

    Brozovich, Faith; Heimberg, Richard G

    2008-07-01

    Research has demonstrated that self-focused thoughts and negative affect have a reciprocal relationship [Mor, N., Winquist, J. (2002). Self-focused attention and negative affect: A meta-analysis. Psychological Bulletin, 128, 638-662]. In the anxiety disorder literature, post-event processing has emerged as a specific construction of repetitive self-focused thoughts that pertain to social anxiety disorder. Post-event processing can be defined as an individual's repeated consideration and potential reconstruction of his performance following a social situation. Post-event processing can also occur when an individual anticipates a social or performance event and begins to brood about other, past social experiences. The present review examined the post-event processing literature in an attempt to organize and highlight the significant results. The methodologies employed to study post-event processing have included self-report measures, daily diaries, social or performance situations created in the laboratory, and experimental manipulations of post-event processing or anticipation of an upcoming event. Directions for future research on post-event processing are discussed.

  15. Improved mutagen testing systems in mice. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roderick, T.H.

    Our laboratory was the first to induce and ascertain a mammalian chromosomal inversion; we did this by searching for a high frequency of first meiotic anaphase bridges in testes of males whose fathers received post-spermatogonial radiation or mutagenesis from chromosomal breaking chemical mutagens. One test in was examined in each mouse, and those showing a high frequency were then mated to determine if the high frequency were passed on as a dominant and whether linkage analysis suggested the presence of an inversion. A very high incidence (exceeding 20% bridges in first meiotic anaphase bridges) was found in about 1 inmore » 150 males examined and this frequency was generally found to be passed on to the offspring an predicted. Later cytological banding techniques were developed elsewhere and we used them to show visually the inverted orders of the inverted chromosomal segments. Since that time we have induced inversions covering most of the mouse genome.« less

  16. Improved mutagen testing systems in mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roderick, T.H.

    Our laboratory was the first to induce and ascertain a mammalian chromosomal inversion; we did this by searching for a high frequency of first meiotic anaphase bridges in testes of males whose fathers received post-spermatogonial radiation or mutagenesis from chromosomal breaking chemical mutagens. One test in was examined in each mouse, and those showing a high frequency were then mated to determine if the high frequency were passed on as a dominant and whether linkage analysis suggested the presence of an inversion. A very high incidence (exceeding 20% bridges in first meiotic anaphase bridges) was found in about 1 inmore » 150 males examined and this frequency was generally found to be passed on to the offspring an predicted. Later cytological banding techniques were developed elsewhere and we used them to show visually the inverted orders of the inverted chromosomal segments. Since that time we have induced inversions covering most of the mouse genome.« less

  17. The Effectiveness of Computer Supported versus Real Laboratory Inquiry Learning Environments on the Understanding of Direct Current Electricity among Pre-Service Elementary School Teachers

    ERIC Educational Resources Information Center

    Baser, Mustafa; Durmus, Soner

    2010-01-01

    The purpose of this study was to compare the changes in conceptual understanding of Direct Current Electricity (DCE) in virtual (VLE) and real laboratory environment (RLE) among pre-service elementary school teachers. A pre- and post-test experimental design was used with two different groups. One of the groups was randomly assigned to VLE (n =…

  18. Quality in the molecular microbiology laboratory.

    PubMed

    Wallace, Paul S; MacKay, William G

    2013-01-01

    In the clinical microbiology laboratory advances in nucleic acid detection, quantification, and sequence analysis have led to considerable improvements in the diagnosis, management, and monitoring of infectious diseases. Molecular diagnostic methods are routinely used to make clinical decisions based on when and how to treat a patient as well as monitor the effectiveness of a therapeutic regime and identify any potential drug resistant strains that may impact on the long term patient treatment program. Therefore, confidence in the reliability of the result provided by the laboratory service to the clinician is essential for patient treatment. Hence, suitable quality assurance and quality control measures are important to ensure that the laboratory methods and service meet the necessary regulatory requirements both at the national and international level. In essence, the modern clinical microbiology laboratory ensures the appropriateness of its services through a quality management system that monitors all aspects of the laboratory service pre- and post-analytical-from patient sample receipt to reporting of results, from checking and upholding staff competency within the laboratory to identifying areas for quality improvements within the service offered. For most European based clinical microbiology laboratories this means following the common International Standard Organization (ISO9001) framework and ISO15189 which sets out the quality management requirements for the medical laboratory (BS EN ISO 15189 (2003) Medical laboratories-particular requirements for quality and competence. British Standards Institute, Bristol, UK). In the United States clinical laboratories performing human diagnostic tests are regulated by the Centers for Medicare and Medicaid Services (CMS) following the requirements within the Clinical Laboratory Improvement Amendments document 1988 (CLIA-88). This chapter focuses on the key quality assurance and quality control requirements within the modern microbiology laboratory providing molecular diagnostics.

  19. The effect of cooperative learning on the attitudes toward science and the achievement of students in a non-science majors' general biology laboratory course at an urban community college

    NASA Astrophysics Data System (ADS)

    Chung-Schickler, Genevieve C.

    The purpose of this study was to evaluate the effect of cooperative learning strategies on students' attitudes toward science and achievement in BSC 1005L, a non-science majors' general biology laboratory course at an urban community college. Data were gathered on the participants' attitudes toward science and cognitive biology level pre and post treatment in BSC 1005L. Elements of the Learning Together model developed by Johnson and Johnson and the Student Team-Achievement Divisions model created by Slavin were incorporated into the experimental sections of BSC 1005L. Four sections of BSC 1005L participated in this study. Participants were enrolled in the 1998 spring (January) term. Students met weekly in a two hour laboratory session. The treatment was administered to the experimental group over a ten week period. A quasi-experimental pretest-posttest control group design was used. Students in the cooperative learning group (nsb1 = 27) were administered the Test of Science-Related Attitudes (TOSRA) and the cognitive biology test at the same time as the control group (nsb2 = 19) (at the beginning and end of the term). Statistical analyses confirmed that both groups were equivalent regarding ethnicity, gender, college grade point average and number of absences. Independent sample t-tests performed on pretest mean scores indicated no significant differences in the TOSRA scale two or biology knowledge between the cooperative learning group and the control group. The scores of TOSRA scales: one, three, four, five, six, and seven were significantly lower in the cooperative learning group. Independent sample t-tests of the mean score differences did not show any significant differences in posttest attitudes toward science or biology knowledge between the two groups. Paired t-tests did not indicate any significant differences on the TOSRA or biology knowledge within the cooperative learning group. Paired t-tests did show significant differences within the control group on TOSRA scale two and biology knowledge. ANCOVAs did not indicate any significant differences on the post mean scores of the TOSRA or biology knowledge adjusted by differences in the pretest mean scores. Analysis of the research data did not show any significant correlation between attitudes toward science and biology knowledge.

  20. Supervised analysis of drug prescription sequences.

    PubMed

    Ficheur, Grégoire; Chazard, Emmanuel; Merlin, Béatrice; Ferret, Laurie; Luyckx, Michel; Beuscart, Régis

    2013-01-01

    Hospitals have at their disposal large databases that may be considered for reuse. The objective of this work is to evaluate the impact of a drug on a specific laboratory result by analyzing these data. This analysis first involves building a record of temporal patterns, including medical context, of drug prescriptions. Changes in outcome due to these patterns of drug prescription are assessed using short phases of the inpatient stay compared to monotonous changes in the laboratory result. To illustrate this technique, we investigated potassium chloride supplementation and its impact on kalemia. This method enables us to assess the impact of a drug (in its frequent context of prescription) on a laboratory result. This kind of analysis could play a role in post-marketing studies.

  1. 7 CFR 94.5 - Charges for laboratory service.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS... costs for analysis of mandatory egg product samples at Science and Technology Division laboratories... program. The costs for any other mandatory laboratory analyses and testing of an egg product's identity...

  2. 7 CFR 94.5 - Charges for laboratory service.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS... costs for analysis of mandatory egg product samples at Science and Technology Division laboratories... program. The costs for any other mandatory laboratory analyses and testing of an egg product's identity...

  3. 7 CFR 94.5 - Charges for laboratory service.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS... costs for analysis of mandatory egg product samples at Science and Technology Division laboratories... program. The costs for any other mandatory laboratory analyses and testing of an egg product's identity...

  4. 7 CFR 94.5 - Charges for laboratory service.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS... costs for analysis of mandatory egg product samples at Science and Technology Division laboratories... program. The costs for any other mandatory laboratory analyses and testing of an egg product's identity...

  5. 75 FR 1179 - Passenger Equipment Safety Standards; Front End Strength of Cab Cars and Multiple-Unit Locomotives

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-08

    ... Dynamic and Quasi-Static Testing in 2008 a. Test Article Design b. Dynamic Testing of a Collision Post c... requirements concerning structural deformation and energy absorption by collision posts and corner posts at the... Testing in 2002 a. Test Article Designs b. Dynamic Impact Testing c. Analysis 2. Industry-Sponsored Quasi...

  6. International Council for Standardization in Haematology (ICSH) Recommendations for Laboratory Measurement of Direct Oral Anticoagulants.

    PubMed

    Gosselin, Robert C; Adcock, Dorothy M; Bates, Shannon M; Douxfils, Jonathan; Favaloro, Emmanuel J; Gouin-Thibault, Isabelle; Guillermo, Cecilia; Kawai, Yohko; Lindhoff-Last, Edelgard; Kitchen, Steve

    2018-03-01

    This guidance document was prepared on behalf of the International Council for Standardization in Haematology (ICSH) for providing haemostasis-related guidance documents for clinical laboratories. This inaugural coagulation ICSH document was developed by an ad hoc committee, comprised of international clinical and laboratory direct acting oral anticoagulant (DOAC) experts. The committee developed consensus recommendations for laboratory measurement of DOACs (dabigatran, rivaroxaban, apixaban and edoxaban), which would be germane for laboratories assessing DOAC anticoagulation. This guidance document addresses all phases of laboratory DOAC measurements, including pre-analytical (e.g. preferred time sample collection, preferred sample type, sample stability), analytical (gold standard method, screening and quantifying methods) and post analytical (e.g. reporting units, quality assurance). The committee addressed the use and limitations of screening tests such as prothrombin time, activated partial thromboplastin time as well as viscoelastic measurements of clotting blood and point of care methods. Additionally, the committee provided recommendations for the proper validation or verification of performance of laboratory assays prior to implementation for clinical use, and external quality assurance to provide continuous assessment of testing and reporting method. Schattauer GmbH Stuttgart.

  7. Coagulation parameters in copperhead compared to other Crotalinae envenomation: secondary analysis of the F(ab')2 versus Fab antivenom trial.

    PubMed

    Gerardo, Charles J; Vissoci, Joao R Nickenig; Brown, Michael W J; Bush, Sean P

    2017-02-01

    Coagulation derangements in copperhead envenomation are considered less severe than other crotaline envenomations, resulting in recommendations to limit both coagulation testing and antivenom treatment. A prospective, blinded, multicenter, randomized clinical trial comparing the effectiveness of F(ab') 2 versus Fab antivenom in crotaline envenomation patients was completed in 2011. We determined the difference between coagulation parameters in copperhead compared to other crotaline envenomations. We performed a post hoc analysis comparing the coagulation parameters (platelets and fibrinogen) prospectively obtained in the aforementioned trial. All the patients received antivenom in one of three treatment arms [F(ab') 2 with maintenance, F(ab') 2 with placebo maintenance, or Fab with maintenance]. Coagulation parameters were measured at pretreatment baseline, during acute hospitalization, day 5, day 8, and day 15 post-envenomation. Mean platelet count and fibrinogen levels for the copperhead and other crotaline groups were compared. The platelet and fibrinogen point estimates with distribution are presented graphically over time. 122 patients were enrolled in the study. There were 22 patients with copperhead envenomation, 93 with other crotaline envenomations, and 7 that could not be definitively determined. The mean age was 42 (SD 20) years. There was a minor pretreatment difference in mean baseline platelet count between the copperhead group (246 × 109/L 95% CI 215, 277) compared to other crotaline envenomation patients (184 × 109/L 95% CI 167, 202). There was a modest pretreatment difference in mean fibrinogen level between copperhead patients (345 mg/dL 95% CI 277, 415) and other crotaline patients (261mg/dL 95% CI 241, 281). Pretreatment coagulation parameter means were normal and converged post treatment. On average, copperhead envenomations have less severe initial coagulation derangements. However, in mild envenomations, differences in laboratory values are minimal and there is substantial variation in individual patients regardless of species. Species alone should not be used to determine the need for laboratory testing or treatment in crotaline snakebite.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, L.L.; Wilson, J.R.; Sanchez, L.C.

    The United States Department of Energy Office of Environmental Management's (DOE/EM's) National Spent Nuclear Fuel Program (NSNFP), through a collaboration between Sandia National Laboratories (SNL) and Idaho National Engineering and Environmental Laboratory (INEEL), is conducting a systematic Nuclear Dynamics Consequence Analysis (NDCA) of the disposal of SNFs in an underground geologic repository sited in unsaturated tuff. This analysis is intended to provide interim guidance to the DOE for the management of the SNF while they prepare for final compliance evaluation. This report presents results from a Nuclear Dynamics Consequence Analysis (NDCA) that examined the potential consequences and risks of criticalitymore » during the long-term disposal of spent nuclear fuel owned by DOE-EM. This analysis investigated the potential of post-closure criticality, the consequences of a criticality excursion, and the probability frequency for post-closure criticality. The results of the NDCA are intended to provide the DOE-EM with a technical basis for measuring risk which can be used for screening arguments to eliminate post-closure criticality FEPs (features, events and processes) from consideration in the compliance assessment because of either low probability or low consequences. This report is composed of an executive summary (Volume 1), the methodology and results of the NDCA (Volume 2), and the applicable appendices (Volume 3).« less

  9. [ABOUT UNIFICATION OF LABORATORY CRITERIA OF DIFFERENTIATION OF BACTERIAL VAGINOSIS].

    PubMed

    Mavzutov, A R; Tsvetkova, A V; Muretdinova, L A

    2015-06-01

    The article presents analysis of laboratory criteria and classifcations used to interpret results of laboratory analysis by technique of microscopy on bacterial vaginosis or dysbacteriosis of vagina. Their advantages and restrictions are demonstrated The unified criteria of evaluation are proposed concerning results of microscopy of mucosal discharge of vagina and corresponding classification. Thereafter, three degrees of bacterial vaginosis (dysbacteriosis of vagina) are differentiated: first degree--compensated dysbacteriosis of vagina, second degree--sub compensated dysbacteriosis of vagina and third degree--decompensated dysbacteriosis of vagina. The corresponding laboratory report of physician is formulated. The proposals are presented concerning development of common unified requirements to stages (pre-analytical, analytical, post-analytical) of laboratory diagnostic of bacterial vaginosis (dysbacteriosis of vagina) with purpose of their unambiguous understanding by clinicians and hence their decision making concerning necessity and tactics of management of patient.

  10. Daniel K. Inouye Solar Telescope: computational fluid dynamic analyses and evaluation of the air knife model

    NASA Astrophysics Data System (ADS)

    McQuillen, Isaac; Phelps, LeEllen; Warner, Mark; Hubbard, Robert

    2016-08-01

    Implementation of an air curtain at the thermal boundary between conditioned and ambient spaces allows for observation over wavelength ranges not practical when using optical glass as a window. The air knife model of the Daniel K. Inouye Solar Telescope (DKIST) project, a 4-meter solar observatory that will be built on Haleakalā, Hawai'i, deploys such an air curtain while also supplying ventilation through the ceiling of the coudé laboratory. The findings of computational fluid dynamics (CFD) analysis and subsequent changes to the air knife model are presented. Major design constraints include adherence to the Interface Control Document (ICD), separation of ambient and conditioned air, unidirectional outflow into the coudé laboratory, integration of a deployable glass window, and maintenance and accessibility requirements. Optimized design of the air knife successfully holds full 12 Pa backpressure under temperature gradients of up to 20°C while maintaining unidirectional outflow. This is a significant improvement upon the .25 Pa pressure differential that the initial configuration, tested by Linden and Phelps, indicated the curtain could hold. CFD post- processing, developed by Vogiatzis, is validated against interferometry results of initial air knife seeing evaluation, performed by Hubbard and Schoening. This is done by developing a CFD simulation of the initial experiment and using Vogiatzis' method to calculate error introduced along the optical path. Seeing error, for both temperature differentials tested in the initial experiment, match well with seeing results obtained from the CFD analysis and thus validate the post-processing model. Application of this model to the realizable air knife assembly yields seeing errors that are well within the error budget under which the air knife interface falls, even with a temperature differential of 20°C between laboratory and ambient spaces. With ambient temperature set to 0°C and conditioned temperature set to 20°C, representing the worst-case temperature gradient, the spatial rms wavefront error in units of wavelength is 0.178 (88.69 nm at λ = 500 nm).

  11. Feasibility of Home-Based Functional Status Assessment of Chronic Obstructive Pulmonary Disease Patients Recovering From an Exacerbation.

    PubMed

    Valeiro, Beatriz; Hernández, Carme; Barberán-Garcia, Anael; Rodríguez, Diego A; Aibar, Jesús; Llop, Lourdes; Vilaró, Jordi

    2016-05-01

    The Glittre Activities of Daily Living Test (ADL-Test) is a reliable functional status measurement for stable chronic obstructive pulmonary disease (COPD) patients in a laboratory setting. We aimed to adapt the test to the home setting (mADL-Test) and to follow-up the functional status recovery of post-exacerbation COPD patients included in a home hospitalization (HH) program. We assessed 17 exacerbated moderate-to-very-severe COPD patients in 3 home visits: at discharge to HH (V0), 10days (V10post) and 1month after discharge (V30post). Patients completed the mADL-Test (laps, VO2 and VE), COPD assessment test (CAT), London Chest ADL Test (LCADL), modified Medical Research Council (mMRC) and upper limb strength (handgrip). The number of laps of the mADL-Test (4, 5 and 5, P<.05), CAT (19, 12 and 12, P<.01), mMRC (2, 1.5 and 1, P<.01) and the self-care domain of the LCADL (6, 5 and 5, P<.01) improved during follow-up (V0, V10post and V30post, respectively). No significant changes were evidenced in VO2, VE or handgrip. Our results suggest that the mADL-test can be performed in the home setting after a COPD exacerbation, and that functional status continues to improve 10days after discharge to HH. Copyright © 2015 SEPAR. Published by Elsevier Espana. All rights reserved.

  12. A randomized controlled trial of an intervention program to Brazilian mothers who use corporal punishment.

    PubMed

    Santini, Paolla Magioni; Williams, Lucia C A

    2017-09-01

    This study evaluated a positive parenting program to Brazilian mothers who used corporal punishment with their children. The intervention was conducted in four agencies serving vulnerable children, and at a home replica laboratory at the University. Mothers who admitted using corporal punishment were randomly assigned between experimental (n=20) and control group (n=20). The program consisted of 12 individual sessions using one unit from Projeto Parceria (Partnership Project), with specific guidelines and materials on positive parenting, followed by observational sessions of mother-child interaction with live coaching and a video feedback session in the lab. The study used an equivalent group experimental design with pre/post-test and follow-up, in randomized controlled trials. Measures involved: Initial Interview; Strengths and Difficulties Questionnaire (SDQ) - parent and child versions; Beck Depression Inventory (BDI); observational sessions with a protocol; and a Program Evaluation by participants. Analysis of mixed models for repeated measures revealed significant positive effects on the BDI and SDQ total scores, as well as less Conduct problems and Hyperactivity in SDQ measures from the experimental group mothers, comparing pre with post-test. Observational data also indicated significant improvement in positive interaction from the experimental group mothers at post-test, in comparison with controls. No significant results were found, however, in children's observational measures. Limitations of the study involved using a restricted sample, among others. Implications for future research are suggested. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Examining evolving performance on the Force Concept Inventory using factor analysis

    NASA Astrophysics Data System (ADS)

    Semak, M. R.; Dietz, R. D.; Pearson, R. H.; Willis, C. W.

    2017-06-01

    The application of factor analysis to the Force Concept Inventory (FCI) has proven to be problematic. Some studies have suggested that factor analysis of test results serves as a helpful tool in assessing the recognition of Newtonian concepts by students. Other work has produced at best ambiguous results. For the FCI administered as a pre- and post-test, we see factor analysis as a tool by which the changes in conceptual associations made by our students may be gauged given the evolution of their response patterns. This analysis allows us to identify and track conceptual linkages, affording us insight as to how our students have matured due to instruction. We report on our analysis of 427 pre- and post-tests. The factor models for the pre- and post-tests are explored and compared along with the methodology by which these models were fit to the data. The post-test factor pattern is more aligned with an expert's interpretation of the questions' content, as it allows for a more readily identifiable relationship between factors and physical concepts. We discuss this evolution in the context of approaching the characteristics of an expert with force concepts. Also, we find that certain test items do not significantly contribute to the pre- or post-test factor models and attempt explanations as to why this is so. This may suggest that such questions may not be effective in probing the conceptual understanding of our students.

  14. Chemical Characterization and Reactivity of Fuel-Oxidizer Reaction Product

    NASA Technical Reports Server (NTRS)

    David, Dennis D.; Dee, Louis A.; Beeson, Harold D.

    1997-01-01

    Fuel-oxidizer reaction product (FORP), the product of incomplete reaction of monomethylhydrazine and nitrogen tetroxide propellants prepared under laboratory conditions and from firings of Shuttle Reaction Control System thrusters, has been characterized by chemical and thermal analysis. The composition of FORP is variable but falls within a limited range of compositions that depend on three factors: the fuel-oxidizer ratio at the time of formation; whether the composition of the post-formation atmosphere is reducing or oxidizing; and the reaction or post-reaction temperature. A typical composition contains methylhydrazinium nitrate, ammonium nitrate, methylammonium nitrate, and trace amounts of hydrazinium nitrate and 1,1-dimethylhydrazinium nitrate. Thermal decomposition reactions of the FORP compositions used in this study were unremarkable. Neither the various compositions of FORP, the pure major components of FORP, nor mixtures of FORP with propellant system corrosion products showed any unusual thermal activity when decomposed under laboratory conditions. Off-limit thruster operations were simulated by rapid mixing of liquid monomethylhydrazine and liquid nitrogen tetroxide in a confined space. These tests demonstrated that monomethylhydrazine, methylhydrazinium nitrate, ammonium nitrate, or Inconel corrosion products can induce a mixture of monomethylhydrazine and nitrogen tetroxide to produce component-damaging energies. Damaging events required FORP or metal salts to be present at the initial mixing of monomethylhydrazine and nitrogen tetroxide.

  15. Development of Metacognitive Skills: Designing Problem-Based Experiment with Prospective Science Teachers in Biology Laboratory

    ERIC Educational Resources Information Center

    Denis Çeliker, Huriye

    2015-01-01

    The purpose of this study is to investigate the effect of designing problem-based experiments (DPBE) on the level of metacognitive skills of prospective science teachers. For this purpose, pre test-post test design, without control group, was used in the research. The research group of the study comprised 113 second-grade prospective science…

  16. In vitro evaluation of endodontic posts.

    PubMed

    Drummond, J L

    2000-05-01

    To compare stainless steel posts and three different fibrous posts with respect to pullout (shear) strength from extracted third molars embedded in denture acrylic. Post space was prepared and the posts cemented with a resin cement according to manufacturer's instructions. Single step and multi-step dentin bonding systems were also evaluated. The testing was in tension at a loading rate of 2 mm/min. The statistical analysis indicated no significant difference in the pullout (shear) strength between any of the post groups tested. Also evaluated was the flexure strength of the fibrous posts before and after thermal cycling. Statistical analysis indicated a significant decrease in flexure strength for the respective fibrous posts following thermal cycling.

  17. Effects of a blended learning module on self-reported learning performances in baccalaureate nursing students.

    PubMed

    Hsu, Li-Ling; Hsieh, Suh-Ing

    2011-11-01

    This article is a report of a quasi-experimental study of the effects of blended modules on nursing students' learning of ethics course content. There is yet to be an empirically supported mix of strategies on which a working blended learning model can be built for nursing education. This was a two-group pretest and post-test quasi-experimental study in 2008 involving a total of 233 students. Two of the five clusters were designated the experimental group to experience a blended learning model, and the rest were designated the control group to be given classroom lectures only. The Case Analysis Attitude Scale, Case Analysis Self-Evaluation Scale, Blended Learning Satisfaction Scale, and Metacognition Scale were used in pretests and post-tests for the students to rate their own performance. In this study, the experimental group did not register significantly higher mean scores on the Case Analysis Attitude Scale at post-test and higher mean ranks on the Case Analysis Self-Evaluation Scale, the Blended Learning Satisfaction Scale, and the Metacognition Scale at post-test than the control group. Moreover, the experimental group registered significant progress in the mean ranks on the Case Analysis Self-Evaluation Scale and the Metacognition Scale from pretest to post-test. No between-subjects effects of four scales at post-test were found. Newly developed course modules, be it blended learning or a combination of traditional and innovative components, should be tested repeatedly for effectiveness and popularity for the purpose of facilitating the ultimate creation of a most effective course module for nursing education. © 2011 Blackwell Publishing Ltd.

  18. Novel, Post-Stall, Thrust-Vectored F-15 RPVs: Laboratory and Flight Tests

    DTIC Science & Technology

    1990-04-24

    Flight Tests Program Manager : Douglas Bowers 1ST-Year Report Principal Investigator: Benjamin 6al-Or April 24, 1990 DTIC.LECTE AUG201990 i/ E...constructed. The geometry, dimensions and preliminary wind-tunnel test data for such a design are provided In Appendix A. If funded, such a 3rd...Preliminary Calibration Flight Test Data Obtained from the Onboard Computer ........ 33 Talless, PST-RaNPAS, Roll-Yaw-Pitch, Thrust-Vectored, PST F-15 (Cf. ADp

  19. College of American Pathologists/American College of Medical Genetics proficiency testing for constitutional cytogenomic microarray analysis.

    PubMed

    Brothman, Arthur R; Dolan, Michelle M; Goodman, Barbara K; Park, Jonathan P; Persons, Diane L; Saxe, Debra F; Tepperberg, James H; Tsuchiya, Karen D; Van Dyke, Daniel L; Wilson, Kathleen S; Wolff, Daynna J; Theil, Karl S

    2011-09-01

    To evaluate the feasibility of administering a newly established proficiency test offered through the College of American Pathologists and the American College of Medical Genetics for genomic copy number assessment by microarray analysis, and to determine the reproducibility and concordance among laboratory results from this test. Surveys were designed through the Cytogenetic Resource Committee of the two colleges to assess the ability of testing laboratories to process DNA samples provided and interpret results. Supplemental questions were asked with each Survey to determine laboratory practice trends. Twelve DNA specimens, representing 2 pilot and 10 Survey challenges, were distributed to as many as 74 different laboratories, yielding 493 individual responses. The mean consensus for matching result interpretations was 95.7%. Responses to supplemental questions indicate that the number of laboratories offering this testing is increasing, methods for analysis and evaluation are becoming standardized, and array platforms used are increasing in probe density. The College of American Pathologists/American College of Medical Genetics proficiency testing program for copy number assessment by cytogenomic microarray is a successful and efficient mechanism for assessing interlaboratory reproducibility. This will provide laboratories the opportunity to evaluate their performance and assure overall accuracy of patient results. The high level of concordance in laboratory responses across all testing platforms by multiple facilities highlights the robustness of this technology.

  20. Tri-Center Analysis: Determining Measures of Trichotomous Central Tendency for the Parametric Analysis of Tri-Squared Test Results

    ERIC Educational Resources Information Center

    Osler, James Edward

    2014-01-01

    This monograph provides an epistemological rational for the design of a novel post hoc statistical measure called "Tri-Center Analysis". This new statistic is designed to analyze the post hoc outcomes of the Tri-Squared Test. In Tri-Center Analysis trichotomous parametric inferential parametric statistical measures are calculated from…

  1. Integration of next-generation sequencing in clinical diagnostic molecular pathology laboratories for analysis of solid tumours; an expert opinion on behalf of IQN Path ASBL.

    PubMed

    Deans, Zandra C; Costa, Jose Luis; Cree, Ian; Dequeker, Els; Edsjö, Anders; Henderson, Shirley; Hummel, Michael; Ligtenberg, Marjolijn Jl; Loddo, Marco; Machado, Jose Carlos; Marchetti, Antonio; Marquis, Katherine; Mason, Joanne; Normanno, Nicola; Rouleau, Etienne; Schuuring, Ed; Snelson, Keeda-Marie; Thunnissen, Erik; Tops, Bastiaan; Williams, Gareth; van Krieken, Han; Hall, Jacqueline A

    2017-01-01

    The clinical demand for mutation detection within multiple genes from a single tumour sample requires molecular diagnostic laboratories to develop rapid, high-throughput, highly sensitive, accurate and parallel testing within tight budget constraints. To meet this demand, many laboratories employ next-generation sequencing (NGS) based on small amplicons. Building on existing publications and general guidance for the clinical use of NGS and learnings from germline testing, the following guidelines establish consensus standards for somatic diagnostic testing, specifically for identifying and reporting mutations in solid tumours. These guidelines cover the testing strategy, implementation of testing within clinical service, sample requirements, data analysis and reporting of results. In conjunction with appropriate staff training and international standards for laboratory testing, these consensus standards for the use of NGS in molecular pathology of solid tumours will assist laboratories in implementing NGS in clinical services.

  2. Research and test facilities for development of technologies and experiments with commercial applications

    NASA Technical Reports Server (NTRS)

    1989-01-01

    One of NASA'S agency-wide goals is the commercial development of space. To further this goal NASA is implementing a policy whereby U.S. firms are encouraged to utilize NASA facilities to develop and test concepts having commercial potential. Goddard, in keeping with this policy, will make the facilities and capabilities described in this document available to private entities at a reduced cost and on a noninterference basis with internal NASA programs. Some of these facilities include: (1) the Vibration Test Facility; (2) the Battery Test Facility; (3) the Large Area Pulsed Solar Simulator Facility; (4) the High Voltage Testing Facility; (5) the Magnetic Field Component Test Facility; (6) the Spacecraft Magnetic Test Facility; (7) the High Capacity Centrifuge Facility; (8) the Acoustic Test Facility; (9) the Electromagnetic Interference Test Facility; (10) the Space Simulation Test Facility; (11) the Static/Dynamic Balance Facility; (12) the High Speed Centrifuge Facility; (13) the Optical Thin Film Deposition Facility; (14) the Gold Plating Facility; (15) the Paint Formulation and Application Laboratory; (16) the Propulsion Research Laboratory; (17) the Wallops Range Facility; (18) the Optical Instrument Assembly and Test Facility; (19) the Massively Parallel Processor Facility; (20) the X-Ray Diffraction and Scanning Auger Microscopy/Spectroscopy Laboratory; (21) the Parts Analysis Laboratory; (22) the Radiation Test Facility; (23) the Ainsworth Vacuum Balance Facility; (24) the Metallography Laboratory; (25) the Scanning Electron Microscope Laboratory; (26) the Organic Analysis Laboratory; (27) the Outgassing Test Facility; and (28) the Fatigue, Fracture Mechanics and Mechanical Testing Laboratory.

  3. Nuclear Dynamics Consequence Analysis (NDCA) for the Disposal of Spent Nuclear Fuel in an Underground Geologic Repository--Volume 2: Methodology and Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, L.L.; Wilson, J.R.; Sanchez, L.C.

    1998-10-01

    The US Department of Energy Office of Environmental Management's (DOE/EM's) National Spent Nuclear Fuel Program (NSNFP), through a collaboration between Sandia National Laboratories (SNL) and Idaho National Engineering and Environmental Laboratory (INEEL), is conducting a systematic Nuclear Dynamics Consequence Analysis (NDCA) of the disposal of SNFs in an underground geologic repository sited in unsaturated tuff. This analysis is intended to provide interim guidance to the DOE for the management of the SNF while they prepare for final compliance evaluation. This report presents results from a Nuclear Dynamics Consequence Analysis (NDCA) that examined the potential consequences and risks of criticality duringmore » the long-term disposal of spent nuclear fuel owned by DOE-EM. This analysis investigated the potential of post-closure criticality, the consequences of a criticality excursion, and the probability frequency for post-closure criticality. The results of the NDCA are intended to provide the DOE-EM with a technical basis for measuring risk which can be used for screening arguments to eliminate post-closure criticality FEPs (features, events and processes) from consideration in the compliance assessment because of either low probability or low consequences. This report is composed of an executive summary (Volume 1), the methodology and results of the NDCA (Volume 2), and the applicable appendices (Volume 3).« less

  4. Laboratory testing and economic analysis of high RAP warm mixed asphalt.

    DOT National Transportation Integrated Search

    2009-03-24

    This report contains laboratory testing, economic analysis, literature review, and information obtained from multiple producers throughout the state of Mississippi regarding the use of high RAP (50 % to 100%) mixtures containing warm mix additives. T...

  5. Evaluation of the impact of a total automation system in a large core laboratory on turnaround time.

    PubMed

    Lou, Amy H; Elnenaei, Manal O; Sadek, Irene; Thompson, Shauna; Crocker, Bryan D; Nassar, Bassam

    2016-11-01

    Growing financial and workload pressures on laboratories coupled with user demands for faster turnaround time (TAT) has steered the implementation of total laboratory automation (TLA). The current study evaluates the impact of a complex TLA on core laboratory efficiency through the analysis of the In-lab to Report TAT (IR-TAT) for five representative tests based on the different requested priorities. Mean, median and outlier percentages (OP) for IR-TAT were determined following TLA implementation and where possible, compared to the pre-TLA era. The shortest mean IR-TAT via the priority lanes of the TLA was 22min for Complete Blood Count (CBC), followed by 34min, 39min and 40min for Prothrombin time (PT), urea and potassium testing respectively. The mean IR-TAT for STAT CBC loaded directly on to the analyzers was 5min shorter than that processed via the TLA. The mean IR-TATs for both STAT potassium and urea via offline centrifugation were comparable to that processed by the TLA. The longest mean IR-TAT via regular lanes of the TLA was 62min for Thyroid-Stimulating Hormone (TSH) while the shortest was 17min for CBC. All parameters for IR-TAT for CBC and PT tests decreased significantly post- TLA across all requested priorities in particular the outlier percentage (OP) at 30 and 60min. TLA helps to efficiently manage substantial volumes of samples across all requested priorities. Manual processing for small STAT volumes, at both the initial centrifugation stage and front loading directly on to analyzers, is however likely to yield the shortest IR-TAT. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. Integrated Data Collection Analysis (IDCA) Program - RDX Type II Class 5 Standard, Data Set 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.

    This document describes the results of the first reference sample material—RDX Type II Class 5—examined in the proficiency study for small-scale safety and thermal (SSST) testing of explosive materials for the Integrated Data Collection Analysis (IDCA) Program. The IDCA program is conducting proficiency testing on homemade explosives (HMEs). The reference sample materials are being studied to establish the accuracy of traditional explosives safety testing for each performing laboratory. These results will be used for comparison to results from testing HMEs. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of thesemore » materials in perspective with standard military explosives. The results of the study will add SSST testing results for a broad suite of different HMEs to the literature, potentially suggest new guidelines and methods for HME testing, and possibly establish what are the needed accuracies in SSST testing to develop safe handling practices. Described here are the results for impact, friction, electrostatic discharge, and scanning calorimetry analysis of a reference sample of RDX Type II Class 5. The results from each participating testing laboratory are compared using identical test material and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. These results are then compared to historical data from various sources. The performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Air Force Research Laboratory/ RXQL (AFRL), Indian Head Division, Naval Surface Warfare Center, (IHD-NSWC), and Sandia National Laboratories (SNL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when test protocols are not identical.« less

  7. Exhaled breath condensate – from an analytical point of view

    PubMed Central

    Dodig, Slavica; Čepelak, Ivana

    2013-01-01

    Over the past three decades, the goal of many researchers is analysis of exhaled breath condensate (EBC) as noninvasively obtained sample. A total quality in laboratory diagnostic processes in EBC analysis was investigated: pre-analytical (formation, collection, storage of EBC), analytical (sensitivity of applied methods, standardization) and post-analytical (interpretation of results) phases. EBC analysis is still used as a research tool. Limitations referred to pre-analytical, analytical, and post-analytical phases of EBC analysis are numerous, e.g. low concentrations of EBC constituents, single-analyte methods lack in sensitivity, and multi-analyte has not been fully explored, and reference values are not established. When all, pre-analytical, analytical and post-analytical requirements are met, EBC biomarkers as well as biomarker patterns can be selected and EBC analysis can hopefully be used in clinical practice, in both, the diagnosis and in the longitudinal follow-up of patients, resulting in better outcome of disease. PMID:24266297

  8. Ecological impacts of the Deepwater Horizon oil spill: implications for immunotoxicity

    EPA Science Inventory

    Summary of major Federal and multi-stake holder research efforts in response to the DWH spill, including laboratory oil dispersant testing, estimation of oil release rates and oil fate calculations, subsea monitoring, and post-spill assessments. Impacts from shoreline oiling, wil...

  9. Failure Pressure and Leak Rate of Steam Generator Tubes With Stress Corrosion Cracks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majumdar, S.; Kasza, K.; Park, J.Y.

    2002-07-01

    This paper illustrates the use of an 'equivalent rectangular crack' approach to predict leak rates through laboratory generated stress corrosion cracks. A comparison between predicted and observed test data on rupture and leak rate from laboratory generated stress corrosion cracks are provided. Specimen flaws were sized by post-test fractography in addition to pre-test advanced eddy current technique. The test failure pressures and leak rates are shown to be closer to those predicted on the basis of fractography than on NDE. However, the predictions based on NDE results are encouraging, particularly because they have the potential to determine a more detailedmore » geometry of ligamentous cracks from which more accurate predictions of failure pressure and leak rate can be made in the future. (authors)« less

  10. Using deep neural networks to augment NIF post-shot analysis

    NASA Astrophysics Data System (ADS)

    Humbird, Kelli; Peterson, Luc; McClarren, Ryan; Field, John; Gaffney, Jim; Kruse, Michael; Nora, Ryan; Spears, Brian

    2017-10-01

    Post-shot analysis of National Ignition Facility (NIF) experiments is the process of determining which simulation inputs yield results consistent with experimental observations. This analysis is typically accomplished by running suites of manually adjusted simulations, or Monte Carlo sampling surrogate models that approximate the response surfaces of the physics code. These approaches are expensive and often find simulations that match only a small subset of observables simultaneously. We demonstrate an alternative method for performing post-shot analysis using inverse models, which map directly from experimental observables to simulation inputs with quantified uncertainties. The models are created using a novel machine learning algorithm which automates the construction and initialization of deep neural networks to optimize predictive accuracy. We show how these neural networks, trained on large databases of post-shot simulations, can rigorously quantify the agreement between simulation and experiment. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  11. Analytical and Experimental Characterization of Gravity Induced Deformations In Subscale Gossamer Structures

    NASA Technical Reports Server (NTRS)

    Johnston, John D.; Blandino, Joseph R.; McEvoy, Kiley C.

    2004-01-01

    The development of gossamer space structures such as solar sails and sunshields presents many challenges due to their large size and extreme flexibility. The post-deployment structural geometry exhibited during ground testing may significantly depart from the in-space configuration due to the presence of gravity-induced deformations (gravity sag) of lightly preloaded membranes. This paper describes a study carried out to characterize gravity sag in two subscale gossamer structures: a single quadrant from a 2 m, 4 quadrant square solar sail and a 1.7 m membrane layer from a multi-layer sunshield The behavior of the test articles was studied over a range of preloads and in several orientations with respect to gravity. An experimental study was carried out to measure the global surface profiles using photogrammetry, and nonlinear finite element analysis was used to predict the behavior of the test articles. Comparison of measured and predicted surface profiles shows that the finite dement analysis qualitatively predicts deformed shapes comparable to those observed in the laboratory. Quantitatively, finite element analysis predictions for peak gravity-induced deformations in both test articles were within 10% of measured values. Results from this study provide increased insight into gravity sag behavior in gossamer structures, and demonstrates the potential to analytically predict gravity-induced deformations to within reasonable accuracy.

  12. Digital versus conventional techniques for pattern fabrication of implant-supported frameworks.

    PubMed

    Alikhasi, Marzieh; Rohanian, Ahmad; Ghodsi, Safoura; Kolde, Amin Mohammadpour

    2018-01-01

    The aim of this experimental study was to compare retention of frameworks cast from wax patterns fabricated by three different methods. Thirty-six implant analogs connected to one-piece abutments were divided randomly into three groups according to the wax pattern fabrication method ( n = 12). Computer-aided design/computer-aided manufacturing (CAD/CAM) milling machine, three-dimensional printer, and conventional technique were used for fabrication of waxing patterns. All laboratory procedures were performed by an expert-reliable technician to eliminate intra-operator bias. The wax patterns were cast, finished, and seated on related abutment analogs. The number of adjustment times was recorded and analyzed by Kruskal-Wallis test. Frameworks were cemented on the corresponding analogs with zinc phosphate cement and tensile resistance test was used to measure retention value. One-way analysis of variance (ANOVA) and post hoc Tukey tests were used for statistical analysis. Level of significance was set at P < 0.05. The mean retentive values of 680.36 ± 21.93 N, 440.48 ± 85.98 N, and 407.23 ± 67.48 N were recorded for CAD/CAM, rapid prototyping, and conventional group, respectively. One-way ANOVA test revealed significant differences among the three groups ( P < 0.001). The post hoc Tukey test showed significantly higher retention for CAD/CAM group ( P < 0.001), while there was no significant difference between the two other groups ( P = 0.54). CAD/CAM group required significantly more adjustments ( P < 0.001). CAD/CAM-fabricated wax patterns showed significantly higher retention for implant-supported cement-retained frameworks; this could be a valuable help when there are limitations in the retention of single-unit implant restorations.

  13. Enhancing graphical literacy skills in the high school science classroom via authentic, intensive data collection and graphical representation exposure

    NASA Astrophysics Data System (ADS)

    Palmeri, Anthony

    This research project was developed to provide extensive practice and exposure to data collection and data representation in a high school science classroom. The student population engaged in this study included 40 high school sophomores enrolled in two microbiology classes. Laboratory investigations and activities were deliberately designed to include quantitative data collection that necessitated organization and graphical representation. These activities were embedded into the curriculum and conducted in conjunction with the normal and expected course content, rather than as a separate entity. It was expected that routine practice with graph construction and interpretation would result in improved competency when graphing data and proficiency in analyzing graphs. To objectively test the effectiveness in achieving this goal, a pre-test and post-test that included graph construction, interpretation, interpolation, extrapolation, and analysis was administered. Based on the results of a paired T-Test, graphical literacy was significantly enhanced by extensive practice and exposure to data representation.

  14. Interlaboratory comparability, bias, and precision for four laboratories measuring analytes in wet deposition, October 1983-December 1984

    USGS Publications Warehouse

    Brooks, Myron H.; Schroder, LeRoy J.; Willoughby, Timothy C.

    1987-01-01

    Four laboratories involved in the routine analysis of wet-deposition samples participated in an interlaboratory comparison program managed by the U.S. Geological Survey. The four participants were: Illinois State Water Survey central analytical laboratory in Champaign, Illinois; U.S. Geological Survey national water-quality laboratories in Atlanta, Georgia, and Denver, Colorado; and Inland Waters Directorate national water-quality laboratory in Burlington, Ontario, Canada. Analyses of interlaboratory samples performed by the four laboratories from October 1983 through December 1984 were compared.Participating laboratories analyzed three types of interlaboratory samples--natural wet deposition, simulated wet deposition, and deionized water--for pH and specific conductance, and for dissolved calcium, magnesium, sodium, sodium, potassium, chloride, sulfate, nitrate, ammonium, and orthophosphate. Natural wet-deposition samples were aliquots of actual wet-deposition samples. Analyses of these samples by the four laboratories were compared using analysis of variance. Test results indicated that pH, calcium, nitrate, and ammonium results were not directly comparable among the four laboratories. Statistically significant differences between laboratory results probably only were meaningful for analyses of dissolved calcium. Simulated wet-deposition samples with known analyte concentrations were used to test each laboratory for analyte bias. Laboratory analyses of calcium, magnesium, sodium, potassium, chloride, sulfate, and nitrate were not significantly different from the known concentrations of these analytes when tested using analysis of variance. Deionized-water samples were used to test each laboratory for reporting of false positive values. The Illinois State Water Survey Laboratory reported the smallest percentage of false positive values for most analytes. Analyte precision was estimated for each laboratory from results of replicate measurements. In general, the Illinois State Water Survey laboratory achieved the greatest precision, whereas the U.S. Geological Survey laboratories achieved the least precision.

  15. Benefits of Using Planned Comparisons Rather Than Post Hoc Tests: A Brief Review with Examples.

    ERIC Educational Resources Information Center

    DuRapau, Theresa M.

    The rationale behind analysis of variance (including analysis of covariance and multiple analyses of variance and covariance) methods is reviewed, and unplanned and planned methods of evaluating differences between means are briefly described. Two advantages of using planned or a priori tests over unplanned or post hoc tests are presented. In…

  16. What Effect Does Story Time Have on Toddlers' Social and Emotional Skills

    ERIC Educational Resources Information Center

    Betawi, I. A.

    2015-01-01

    The purpose of this study is to investigate the effect of story time and reading stories on the development of toddlers' social and emotional skills between 24 and 36 months of age. A sample of 10 toddlers was randomly selected from three different classes at the laboratory nursery of The University of Jordan. A pre-test and post-test were…

  17. Impact of an incremental running test on jumping kinematics in endurance runners: can jumping kinematic explain the post-activation potentiation phenomenon?

    PubMed

    García-Pinillos, Felipe; Molina-Molina, Alejandro; Latorre-Román, Pedro Á

    2016-06-01

    This study aimed to determine whether kinematic data during countermovement jump (CMJ) might explain post-activation potentiation (PAP) phenomenon after an exhausting running test. Thirty-three trained endurance runners performed the Léger Test; an incremental test which consists of continuous running between two lines 20 m apart. CMJ performance was determined before (pre-test) and immediately after the protocol (post-test). Sagittal plane, video of CMJs was recorded and kinematic data were obtained throughout 2-Dimensional analysis. In addition to the duration of eccentric and concentric phases of CMJ, hip, knee and ankle angles were measured at four key points during CMJ: the lowest position of the squat, take-off, landing, and at the lowest position after landing. Additionally, heart rate was monitored, and rate of perceived exertion was recorded at post-test. Analysis of variance revealed a significant improvement in CMJ (p = 0.002) at post-test. Cluster analysis grouped according to whether PAP was experienced (responders group: RG, n = 25) or not (non-responders group: NRG, n = 8) relative to CMJ change from rest to post-test. RG significantly improved (p < 0.001) the performance in CMJ, whereas NRG remained unchanged. Kinematic data did not show significant differences between RG and NRG. Thus, the data suggest that jumping kinematic does not provide the necessary information to explain PAP phenomenon after intensive running exercises in endurance athletes.

  18. Trial Support and Data Analysis for 2015 ONR Sea-Trial

    DTIC Science & Technology

    2017-06-21

    Report Chad M. Smith The Pennsylvania State University Applied Research Laboratory P.O. Box 30 State College, PA 16804-0030 phone: (814) 863...was the support of the PI and Penn State Applied Research Laboratory (PSU-ARL) technicians for demobilization and post-experimental cleanup of the...NAME(S) AND ADDRESS(ES) The Pennsylvania State University Applied Research Labotatory Office of Sponsored Programs 110 Technology Center Building

  19. Comparison of multianalyte proficiency test results by sum of ranking differences, principal component analysis, and hierarchical cluster analysis.

    PubMed

    Škrbić, Biljana; Héberger, Károly; Durišić-Mladenović, Nataša

    2013-10-01

    Sum of ranking differences (SRD) was applied for comparing multianalyte results obtained by several analytical methods used in one or in different laboratories, i.e., for ranking the overall performances of the methods (or laboratories) in simultaneous determination of the same set of analytes. The data sets for testing of the SRD applicability contained the results reported during one of the proficiency tests (PTs) organized by EU Reference Laboratory for Polycyclic Aromatic Hydrocarbons (EU-RL-PAH). In this way, the SRD was also tested as a discriminant method alternative to existing average performance scores used to compare mutlianalyte PT results. SRD should be used along with the z scores--the most commonly used PT performance statistics. SRD was further developed to handle the same rankings (ties) among laboratories. Two benchmark concentration series were selected as reference: (a) the assigned PAH concentrations (determined precisely beforehand by the EU-RL-PAH) and (b) the averages of all individual PAH concentrations determined by each laboratory. Ranking relative to the assigned values and also to the average (or median) values pointed to the laboratories with the most extreme results, as well as revealed groups of laboratories with similar overall performances. SRD reveals differences between methods or laboratories even if classical test(s) cannot. The ranking was validated using comparison of ranks by random numbers (a randomization test) and using seven folds cross-validation, which highlighted the similarities among the (methods used in) laboratories. Principal component analysis and hierarchical cluster analysis justified the findings based on SRD ranking/grouping. If the PAH-concentrations are row-scaled, (i.e., z scores are analyzed as input for ranking) SRD can still be used for checking the normality of errors. Moreover, cross-validation of SRD on z scores groups the laboratories similarly. The SRD technique is general in nature, i.e., it can be applied to any experimental problem in which multianalyte results obtained either by several analytical procedures, analysts, instruments, or laboratories need to be compared.

  20. The diagnostic performance of coronary artery angiography with 64-MSCT and post 64-MSCT: systematic review and meta-analysis.

    PubMed

    Li, Min; Du, Xiang-Min; Jin, Zhi-Tao; Peng, Zhao-Hui; Ding, Juan; Li, Li

    2014-01-01

    To comprehensively investigate the diagnostic performance of coronary artery angiography with 64-MDCT and post 64-MDCT. PubMed was searched for all published studies that evaluated coronary arteries with 64-MDCT and post 64-MDCT. The clinical diagnostic role was evaluated by applying the likelihood ratios (LRs) to calculate the post-test probability based on Bayes' theorem. 91 studies that met our inclusion criteria were ultimately included in the analysis. The pooled positive and negative LRs at patient level were 8.91 (95% CI, 7.53, 10.54) and 0.02 (CI, 0.01, 0.03), respectively. For studies that did not claim that non-evaluable segments were included, the pooled positive and negative LRs were 11.16 (CI, 8.90, 14.00) and 0.01 (CI, 0.01, 0.03), respectively. For studies including uninterruptable results, the diagnostic performance decreased, with the pooled positive LR 7.40 (CI, 6.00, 9.13) and negative LR 0.02 (CI, 0.01, 0.03). The areas under the summary ROC curve were 0.98 (CI, 0.97 to 0.99) for 64-MDCT and 0.96 (CI, 0.94 to 0.98) for post 64-MDCT, respectively. For references explicitly stating that the non-assessable segments were included during analysis, a post-test probability of negative results >95% and a positive post-test probability <95% could be obtained for patients with a pre-test probability of <73% for coronary artery disease (CAD). On the other hand, when the pre-test probability of CAD was >73%, the diagnostic role was reversed, with a positive post-test probability of CAD >95% and a negative post-test probability of CAD <95%. The diagnostic performance of post 64-MDCT does not increase as compared with 64-MDCT. CTA, overall, is a test of exclusion for patients with a pre-test probability of CAD<73%, while for patients with a pre-test probability of CAD>73%, CTA is a test used to confirm the presence of CAD.

  1. Characterization of Mineralocorticoid Receptor Antagonist Therapy Initiation in High-Risk Patients With Heart Failure.

    PubMed

    Cooper, Lauren B; Hammill, Bradley G; Peterson, Eric D; Pitt, Bertram; Maciejewski, Matthew L; Curtis, Lesley H; Hernandez, Adrian F

    2017-01-01

    Heart failure guidelines recommend routine monitoring of serum potassium, and renal function in patients treated with a mineralocorticoid receptor antagonist (MRA). How these recommendations are implemented in high-risk patients or according to setting of drug initiation is poorly characterized. We conducted a retrospective cohort study of Medicare beneficiaries linked to laboratory data in 10 states with prevalent heart failure as of July 1, 2011, and incident MRA use between May 1 and September 30, 2011. Outcomes included laboratory testing before MRA initiation and in the early (days 1-10) and extended (days 11-90) post-initiation periods, based on setting of drug initiation and the presence of renal insufficiency. Additional outcomes included abnormal laboratory results and adverse events proximate to MRA initiation. Of 10 443 Medicare beneficiaries with heart failure started on an MRA, 19.7% were initiated during a hospitalization. Appropriate follow-up laboratory testing across all time periods occurred in 25.2% of patients with inpatient initiation compared with 2.8% of patients begun as an outpatient. Patients with chronic kidney disease had higher rates of both hyperkalemia and acute kidney failure in the early (1.3% and 2.7%, respectively) and extended (5.6% and 9.8%, respectively) post-initiation periods compared with those without chronic kidney disease. Patients initiated on MRA therapy as an outpatient had extremely poor rates of guideline indicated follow-up laboratory monitoring after drug initiation. In particular, patients with chronic kidney disease are at high risk for adverse events after MRA initiation. Quality improvement initiatives focused on systems to improve appropriate laboratory monitoring are needed. © 2017 American Heart Association, Inc.

  2. Assessing effects of the e-Chasqui laboratory information system on accuracy and timeliness of bacteriology results in the Peruvian tuberculosis program.

    PubMed

    Blaya, Joaquin A; Shin, Sonya S; Yagui, Martin J A; Yale, Gloria; Suarez, Carmen; Asencios, Luis; Fraser, Hamish

    2007-10-11

    We created a web-based laboratory information system, e-Chasqui to connect public laboratories to health centers to improve communication and analysis. After one year, we performed a pre and post assessment of communication delays and found that e-Chasqui maintained the average delay but eliminated delays of over 60 days. Adding digital verification maintained the average delay, but should increase accuracy. We are currently performing a randomized evaluation of the impacts of e-Chasqui.

  3. STS-29 MS Bagian during post landing egress exercises in JSC FFT mockup

    NASA Image and Video Library

    1988-05-26

    S88-38355 (27 May 1988) --- Astronaut James P. Bagian lowers himself from the top of one of the full-fuselage trainer in JSC's Shuttle mockup and integration laboratory during a post-landing, over-the-top emergency egress test. Bagian, a M.D., and one of three mission specialists assigned to NASA STS-29 flight of the Discovery, is working with engineers evaluating egress using the new crew escape equipment that includes a parachute harness.

  4. Analysis of STAT laboratory turnaround times before and after conversion of the hospital information system.

    PubMed

    Lowe, Gary R; Griffin, Yolanda; Hart, Michael D

    2014-08-01

    Modern electronic health record systems (EHRS) reportedly offer advantages including improved quality, error prevention, cost reduction, and increased efficiency. This project reviewed the impact on specimen turnaround times (TAT) and percent compliance for specimens processed in a STAT laboratory after implementation of an upgraded EHRS. Before EHRS implementation, laboratory personnel received instruction and training for specimen processing. One laboratory member per shift received additional training. TAT and percent compliance data sampling occurred 4 times monthly for 13 months post-conversion and were compared with the mean of data collected for 3 months pre-conversion. Percent compliance was gauged using a benchmark of reporting 95% of all specimens within 7 min from receipt. Control charts were constructed for TAT and percent compliance with control limits set at 2 SD and applied continuously through the data collection period. TAT recovered to pre-conversion levels by the 6th month post-conversion. Percent compliance consistently returned to pre-conversion levels by the 10th month post-conversion. Statistical analyses revealed the TAT were significantly longer for 3 months post-conversion (P < .001) compared with pre-conversion levels. Statistical significance was not observed for subsequent groups. Percent compliance results were significantly lower for 6 months post-conversion (P < .001). Statistical significance was not observed for subsequent groups. Extensive efforts were made to train and prepare personnel for challenges expected after the EHRS upgrade. Specific causes identified with the upgraded EHRS included multiple issues involving personnel and the EHRS. These data suggest that system and user issues contributed to delays in returning to pre-conversion TAT and percent compliance levels following the upgrade in the EHRS.

  5. Laboratory and Field Evaluation of a New Rapid Test for Detecting Wuchereria bancrofti Antigen in Human Blood

    PubMed Central

    Weil, Gary J.; Curtis, Kurt C.; Fakoli, Lawrence; Fischer, Kerstin; Gankpala, Lincoln; Lammie, Patrick J.; Majewski, Andrew C.; Pelletreau, Sonia; Won, Kimberly Y.; Bolay, Fatorma K.; Fischer, Peter U.

    2013-01-01

    Global Program to Eliminate Lymphatic Filariasis (GPELF) guidelines call for using filarial antigen testing to identify endemic areas that require mass drug administration (MDA) and for post-MDA surveillance. We compared a new filarial antigen test (the Alere Filariasis Test Strip) with the reference BinaxNOW Filariasis card test that has been used by the GPELF for more than 10 years. Laboratory testing of 227 archived serum or plasma samples showed that the two tests had similar high rates of sensitivity and specificity and > 99% agreement. However, the test strip detected 26.5% more people with filarial antigenemia (124/503 versus 98/503) and had better test result stability than the card test in a field study conducted in a filariasis-endemic area in Liberia. Based on its increased sensitivity and other practical advantages, we believe that the test strip represents a major step forward that will be welcomed by the GPELF and the filariasis research community. PMID:23690552

  6. Tailless Vectored Fighters Theory. Laboratory and Flight Tests, Including Vectorable Inlets/Nozzles and Tailless Flying Models vs. Pilot’s Tolerances Affecting Maximum Post-Stall Vectoring Agility.

    DTIC Science & Technology

    1991-07-01

    nose bodyj Top view of velocity probe PropllerRotating shaft ’V Generator Aerodynamic shape like a small elevator RPV’s attitude Irrespctiveduring...28 Part It: Maximizing Thrust-Vectoring Control Power and Agility Metrics ............ 29 Laboratory & Flight...8217Ideal Standards’ - Ba- ror maximizing PST-TV-aglilty/rIlght-control power , iI - Extracting new TV-potentials to further reduce any righter’s optical

  7. Can pore-clogging by ash explain post-fire runoff?

    USGS Publications Warehouse

    Stoof, Cathelijne R.; Gevaert, Anouk I.; Baver, Christine; Hassanpour, Bahareh; Morales, Veronica L.; Zhang, Wei; Martin, Deborah; Giri, Shree K.; Steenhuis, Tammo S.

    2016-01-01

    Ash plays an important role in controlling runoff and erosion processes after wildfire and has frequently been hypothesised to clog soil pores and reduce infiltration. Yet evidence for clogging is incomplete, as research has focussed on identifying the presence of ash in soil; the actual flow processes remain unknown. We conducted laboratory infiltration experiments coupled with microscope observations in pure sands, saturated hydraulic conductivity analysis, and interaction energy calculations, to test whether ash can clog pores (i.e. block pores such that infiltration is hampered and ponding occurs). Although results confirmed previous observations of ash washing into pores, clogging was not observed in the pure sands tested, nor were conditions found for which this does occur. Clogging by means of strong attachment of ash to sand was deemed unlikely given the negative surface charge of the two materials. Ponding due to washing in of ash was also considered improbable given the high saturated conductivity of pure ash and ash–sand mixtures. This first mechanistic step towards analysing ash transport and attachment processes in field soils therefore suggests that pore clogging by ash is unlikely to occur in sands. Discussion is provided on other mechanisms by which ash can affect post-fire hydrology.

  8. The Use of the Molecular Adsorber Coating Technology to Mitigate Vacuum Chamber Contamination During Pathfinder Testing for the James Webb Space Telescope

    NASA Technical Reports Server (NTRS)

    Abraham, Nithin S.; Hasegawa, Mark M.; Wooldridge, Eve M.; Henderson-Nelson, Kelly A.

    2016-01-01

    As a coating made of highly porous zeolite materials, the Molecular Adsorber Coating (MAC) was developed to capture outgassed molecular contaminants, such as hydrocarbons and silicones. For spaceflight applications, the adsorptive capabilities of the coating can alleviate on-orbit outgassing concerns on or near sensitive surfaces and instruments within the spacecraft. Similarly, this sprayable paint technology has proven to be significantly beneficial for ground based space applications, in particular, for vacuum chamber environments. This paper describes the recent use of the MAC technology during Pathfinder testing of the Optical Ground Support Equipment (OGSE) for the James Webb Space Telescope (JWST) at NASA Johnson Space Center (JSC). The coating was used as a mitigation tool to entrap persistent outgassed contaminants, specifically silicone based diffusion pump oil, from within JSC's cryogenic optical vacuum chamber test facility called Chamber A. This paper summarizes the sample fabrication, installation, laboratory testing, post-test chemical analysis results, and future plans for the MAC technology, which was effectively used to protect the JWST test equipment from vacuum chamber contamination.

  9. The use of the Molecular Adsorber Coating technology to mitigate vacuum chamber contamination during Pathfinder testing for the James Webb Space Telescope

    NASA Astrophysics Data System (ADS)

    Abraham, Nithin S.; Hasegawa, Mark M.; Wooldridge, Eve M.; Henderson-Nelson, Kelly A.

    2016-09-01

    As a coating made of highly porous zeolite materials, the Molecular Adsorber Coating (MAC) was developed to capture outgassed molecular contaminants, such as hydrocarbons and silicones. For spaceflight applications, the adsorptive capabilities of the coating can alleviate on-orbit outgassing concerns on or near sensitive surfaces and instruments within the spacecraft. Similarly, this sprayable paint technology has proven to be significantly beneficial for ground based space applications, in particular, for vacuum chamber environments. This paper describes the recent use of the MAC technology during Pathfinder testing of the Optical Ground Support Equipment (OGSE) for the James Webb Space Telescope (JWST) at NASA Johnson Space Center (JSC). The coating was used as a mitigation tool to entrap persistent outgassed contaminants, specifically silicone based diffusion pump oil, from within JSC's cryogenic optical vacuum chamber test facility called Chamber A. This paper summarizes the sample fabrication, installation, laboratory testing, post-test chemical analysis results, and future plans for the MAC technology, which was effectively used to protect the JWST test equipment from vacuum chamber contamination.

  10. Introduction of a fresh cadaver laboratory during the surgery clerkship improves emergency technical skills.

    PubMed

    Nematollahi, Saman; Kaplan, Stephen J; Knapp, Christopher M; Ho, Hang; Alvarado, Jared; Viscusi, Rebecca; Adamas-Rappaport, William

    2015-08-01

    Student acquisition of technical skills during the clinical years of medical school has been steadily declining. To address this issue, the authors instituted a fresh cadaver-based Emergency Surgical Skills Laboratory (ESSL). Sixty-three medical students rotating through the third-year surgery clerkship participated in a 2-hour, fresh cadaver-based ESSL conducted during the first 2 days of the clerkship. The authors evaluated students utilizing both surgical skills and written examination before the ESSL and at 4 weeks post ESSL. Students demonstrated a mean improvement of 64% (±11) (P < .001) and 38% (±17) (P < .001) in technical skills and clinical knowledge, respectively. When technical skills were compared between cohorts, there were no differences observed in both pre- and post-testing (P = .08). A fresh cadaver laboratory is an effective method to provide proficiency in emergency technical skills not acquired during the clinical years of medical school. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Remote Sensing Image Quality Assessment Experiment with Post-Processing

    NASA Astrophysics Data System (ADS)

    Jiang, W.; Chen, S.; Wang, X.; Huang, Q.; Shi, H.; Man, Y.

    2018-04-01

    This paper briefly describes the post-processing influence assessment experiment, the experiment includes three steps: the physical simulation, image processing, and image quality assessment. The physical simulation models sampled imaging system in laboratory, the imaging system parameters are tested, the digital image serving as image processing input are produced by this imaging system with the same imaging system parameters. The gathered optical sampled images with the tested imaging parameters are processed by 3 digital image processes, including calibration pre-processing, lossy compression with different compression ratio and image post-processing with different core. Image quality assessment method used is just noticeable difference (JND) subject assessment based on ISO20462, through subject assessment of the gathered and processing images, the influence of different imaging parameters and post-processing to image quality can be found. The six JND subject assessment experimental data can be validated each other. Main conclusions include: image post-processing can improve image quality; image post-processing can improve image quality even with lossy compression, image quality with higher compression ratio improves less than lower ratio; with our image post-processing method, image quality is better, when camera MTF being within a small range.

  12. Computer and laboratory simulation in the teaching of neonatal nursing: innovation and impact on learning 1

    PubMed Central

    Fonseca, Luciana Mara Monti; Aredes, Natália Del' Angelo; Fernandes, Ananda Maria; Batalha, Luís Manuel da Cunha; Apóstolo, Jorge Manuel Amado; Martins, José Carlos Amado; Rodrigues, Manuel Alves

    2016-01-01

    ABSTRACT Objectives: to evaluate the cognitive learning of nursing students in neonatal clinical evaluation from a blended course with the use of computer and laboratory simulation; to compare the cognitive learning of students in a control and experimental group testing the laboratory simulation; and to assess the extracurricular blended course offered on the clinical assessment of preterm infants, according to the students. Method: a quasi-experimental study with 14 Portuguese students, containing pretest, midterm test and post-test. The technologies offered in the course were serious game e-Baby, instructional software of semiology and semiotechnique, and laboratory simulation. Data collection tools developed for this study were used for the course evaluation and characterization of the students. Nonparametric statistics were used: Mann-Whitney and Wilcoxon. Results: the use of validated digital technologies and laboratory simulation demonstrated a statistically significant difference (p = 0.001) in the learning of the participants. The course was evaluated as very satisfactory for them. The laboratory simulation alone did not represent a significant difference in the learning. Conclusions: the cognitive learning of participants increased significantly. The use of technology can be partly responsible for the course success, showing it to be an important teaching tool for innovation and motivation of learning in healthcare. PMID:27737376

  13. Effective geoscience pedagogy at the undergraduate level

    NASA Astrophysics Data System (ADS)

    Warden, Kelsey

    This investigation used constructivist pedagogical methods within the framework of an introductory level undergraduate geoscience course to gauge both the changes in attitude and cognition of students. Pedagogy was modified in the laboratory setting, but maintained in the lecture setting and homework. Curriculum was also maintained in the lecture, but was changed in the laboratory to emphasize the large concepts and systems stressed in Earth Science Literacy Principles. Student understanding of these concepts and systems was strengthened by factual knowledge, but recall and memorization were not the goal of the laboratory instruction. The overall goal of the study was to build student understanding more effectively than in previous semesters such that the students would become Earth Science literate adults. We hypothesized that a healthy comprehension of the connections between the human population and Earth's systems would lead to improved cognition and attitude toward Earth Science. This was tested using pre- and post-testing of attitudes via an anonymous survey on the first and last days of the laboratory, student responses to the end-of-course evaluations, and student performance on early-semester and late-semester content testing. The results support the hypotheses.

  14. The time-associated impact of the Newborn Influenza Protection Act on infant influenza rates in New York State.

    PubMed

    Shah, Shetal; Messina, Catherine

    2014-11-01

    Influenza presents with increased morbidity and mortality in children ≤5 months of age. Vaccination of caregivers is indicated, but immunization rates are estimated at only 30%. The 2009 New York State Neonatal Influenza Protection Act (NIPA) mandated offering of influenza vaccine to caregivers during the post-partum hospitalization. The purpose of this study was to determine the impact of NIPA on infant influenza rates. Data on laboratory-confirmed influenza cases between 2006 and 2012 were extracted from the New York State Electronic Clinical Laboratory Reporting System (ECLRS). Data on infant cases were categorized by age (0-5 months) and location [New York City (NYC), outside NYC] based on reporting laboratory site. The total number of influenza cases and the percentage of total cases in the infant age group were normalized to the number of reporting laboratory sites. The χ2-test was used to compare the proportions of cases pre- and post-implementation. Year-to-year trends were assessed by linear regression. All tests of significance were two-sided and evaluated at the P<0.05 level. During the 6-year study period, 3154 cases of infant influenza were detected. In bivariate analysis, 1707 (54.1%) of cases occurred prior to NIPA implementation and 1447 (45.9%) of cases occurred after (P<0.001). Of the 1422 total infant cases detected in NYC, the percentages of influenza cases pre- and post-NIPA were 54.6% (777) and 45.4% (645), respectively (P<0.006). Outside NYC, the percentage of infant cases was reduced from 53.7% (930/1732) to 46.3% (802/1732, P<0.02). Prior to implementation, there was a year-to-year increase in the number of infant influenza cases statewide (P<0.04 for trend). The ratio of infant influenza cases normalized per ECLRS site in NYC increased each year after NIPA passage (P<0.01 for trend). The ratio of infant cases outside NYC decreased annually (P<0.05 for trend). No year-to-year trends were seen in the percentage of total influenza cases in the infant age group compared to total cases across all age groups either within or outside NYC. Comparison of three influenza seasons before and after NIPA suggests a total statewide reduction in infant influenza. However, the greatest driver of this reduction occurs from reduced disease in infants outside NYC. We speculate that, with increased crowding within NYC, parental immunization as encouraged by NIPA may not create cocoon immunity.

  15. Naval Medical Research and Development News. Volume 7, Issue 9

    DTIC Science & Technology

    2015-09-01

    the simulated training; career intentions; and, general, occupational, and task-specific self-efficacy using pretest and post - test surveys from a...DTRA). On August 31, a state-of-the-art laboratory, designed and equipped by NAMRU-2 utilizing DTRA funding, was officially opened at the Ream...transported to the labs for testing . What was needed was a rapid, on -site, diagnostic test that could be done quickly. “The U.S. Centers for Disease

  16. Computer assisted performance tests of the Lyman Alpha Coronagraph

    NASA Technical Reports Server (NTRS)

    Parkinson, W. H.; Kohl, J. L.

    1979-01-01

    Preflight calibration and performance tests of the Lyman Alpha Coronagraph rocket instrument in the laboratory, with the experiment in its flight configuration and illumination levels near those expected during flight were successfully carried out using a pulse code modulation telemetry system simulator interfaced in real time to a PDP 11/10 computer system. Post acquisition data reduction programs developed and implemented on the same computer system aided in the interpretation of test and calibration data.

  17. 75 FR 17281 - Changes in Hourly Fee Rates for Science and Technology Laboratory Services-Fiscal Years 2010-2012

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-06

    ..., residue chemistry, proximate analysis for composition, and biomolecular (DNA-based) testing. A user fee... provide greater clarity of reported test analyses and laboratory determinations. DATES: Effective April 7... analyses and laboratory determinations provided by AMS laboratory services apply only to the submitted...

  18. Clinical Assessment of Tribulus terrestris Extract in the Treatment of Female Sexual Dysfunction

    PubMed Central

    Gama, Carlos RB; Lasmar, Ricardo; Gama, Gustavo F; Abreu, Camila S; Nunes, Carlos P; Geller, Mauro; Oliveira, Lisa; Santos, Alessandra

    2014-01-01

    This is a qualitative–quantitative study based on hospital records of female patients of reproductive age, presenting sexual dysfunction, and treated with 250 mg Tribulus terrestris extract (1 tablet thrice daily for 90 days). Safety monitoring included vital signs, physical examination, laboratory tests, and occurrence of adverse events. Efficacy analysis included results of the Female Sexual Function Index (FSFI), dehydroepiandrosterone (DHEA) levels together with total and free testosterone, and the patient and physician assessments. There was a statistically significant improvement in total FSFI scores (P < 0.0001) post-treatment, with improvement among 106 (88.33%) subjects. There was a statistically significant (P < 0.0001) increase in the level of DHEA, while the levels of both serum testosterone (P = 0.284) and free testosterone decreased (P < 0.0001). Most adverse events recorded were related to the gastrointestinal tract. Physical examination showed no significant changes post-treatment. Based on the results, it is concluded that the T. terrestris extract is safe and effective in the treatment of female sexual dysfunction. PMID:25574150

  19. Clinical Assessment of Tribulus terrestris Extract in the Treatment of Female Sexual Dysfunction.

    PubMed

    Gama, Carlos Rb; Lasmar, Ricardo; Gama, Gustavo F; Abreu, Camila S; Nunes, Carlos P; Geller, Mauro; Oliveira, Lisa; Santos, Alessandra

    2014-01-01

    This is a qualitative-quantitative study based on hospital records of female patients of reproductive age, presenting sexual dysfunction, and treated with 250 mg Tribulus terrestris extract (1 tablet thrice daily for 90 days). Safety monitoring included vital signs, physical examination, laboratory tests, and occurrence of adverse events. Efficacy analysis included results of the Female Sexual Function Index (FSFI), dehydroepiandrosterone (DHEA) levels together with total and free testosterone, and the patient and physician assessments. There was a statistically significant improvement in total FSFI scores (P < 0.0001) post-treatment, with improvement among 106 (88.33%) subjects. There was a statistically significant (P < 0.0001) increase in the level of DHEA, while the levels of both serum testosterone (P = 0.284) and free testosterone decreased (P < 0.0001). Most adverse events recorded were related to the gastrointestinal tract. Physical examination showed no significant changes post-treatment. Based on the results, it is concluded that the T. terrestris extract is safe and effective in the treatment of female sexual dysfunction.

  20. Changes in infant disposable diaper weights at selected intervals post-wetting.

    PubMed

    Carlisle, Joan; Moore, Amanda; Cooper, Alyssa; Henderson, Terri; Mayfield, Debbie; Taylor, Randa; Thomas, Jennifer; Van Fleet, Laduska; Askanazi, David; Fineberg, Naomi; Sun, Yanhui

    2012-01-01

    Pediatric acute care nurses questioned the practice of weighing disposable infant diapers immediately after voiding. This study asked the research question, "Does volume of saline, diaper configuration, and/or size of diaper statistically effect changes in diaper weights over time?" The method was an experimental, laboratory model. Pre-set volumes of saline were added to disposable diapers that were then left folded or unfolded. Each diaper was weighed immediately post-wetting and re-weighed at hourly intervals for seven hours. Data were analyzed using a repeated measures analysis of variance (RMANOVA) with balanced data (F-test). Diaper weight changes over time were statistically significant for all time points and for all volumes regardless of diaper size; however, the changes in weight were small and without clinical significance. It is appropriate to weigh diapers at the end of eight hours without risk of altering subsequent fluid management of patients in open-air, non-humidified environments. This practice has led to more efficient use of nurses' time with fewer interruptions for patients and families.

  1. An Improved Flame Test for Qualitative Analysis Using a Multichannel UV-Visible Spectrophotometer

    ERIC Educational Resources Information Center

    Blitz, Jonathan P.; Sheeran, Daniel J.; Becker, Thomas L.

    2006-01-01

    Qualitative analysis schemes are used in undergraduate laboratory settings as a way to introduce equilibrium concepts and logical thinking. The main component of all qualitative analysis schemes is a flame test, as the color of light emitted from certain elements is distinctive and a flame photometer or spectrophotometer in each laboratory is…

  2. Clinical Evaluation of a Loop-Mediated Amplification Kit for Diagnosis of Imported Malaria

    PubMed Central

    Polley, Spencer D.; González, Iveth J.; Mohamed, Deqa; Daly, Rosemarie; Bowers, Kathy; Watson, Julie; Mewse, Emma; Armstrong, Margaret; Gray, Christen; Perkins, Mark D.; Bell, David; Kanda, Hidetoshi; Tomita, Norihiro; Kubota, Yutaka; Mori, Yasuyoshi; Chiodini, Peter L.; Sutherland, Colin J.

    2013-01-01

    Background. Diagnosis of malaria relies on parasite detection by microscopy or antigen detection; both fail to detect low-density infections. New tests providing rapid, sensitive diagnosis with minimal need for training would enhance both malaria diagnosis and malaria control activities. We determined the diagnostic accuracy of a new loop-mediated amplification (LAMP) kit in febrile returned travelers. Methods. The kit was evaluated in sequential blood samples from returned travelers sent for pathogen testing to a specialist parasitology laboratory. Microscopy was performed, and then malaria LAMP was performed using Plasmodium genus and Plasmodium falciparum–specific tests in parallel. Nested polymerase chain reaction (PCR) was performed on all samples as the reference standard. Primary outcome measures for diagnostic accuracy were sensitivity and specificity of LAMP results, compared with those of nested PCR. Results. A total of 705 samples were tested in the primary analysis. Sensitivity and specificity were 98.4% and 98.1%, respectively, for the LAMP P. falciparum primers and 97.0% and 99.2%, respectively, for the Plasmodium genus primers. Post hoc repeat PCR analysis of all 15 tests with discrepant results resolved 4 results in favor of LAMP, suggesting that the primary analysis had underestimated diagnostic accuracy. Conclusions. Malaria LAMP had a diagnostic accuracy similar to that of nested PCR, with a greatly reduced time to result, and was superior to expert microscopy. PMID:23633403

  3. [Miyake-Apple video analysis of movement patterns of an accommodative intraocular lens implant].

    PubMed

    Auffarth, G U; Schmidbauer, J; Becker, K A; Rabsilber, T M; Apple, D J

    2002-11-01

    The potentially accommodative intraocular lens (IOL) is a new development in IOL design We evaluated the new Humanoptics 1CU accommodative IOL in a laboratory study with human post mortem autopsy eyes. Using the Miyake-Apple posterior view video technique, the movement pattern of the IOL was tested and observed from the posterior perspective. RESULTS. A circular bend at the level of the ciliary body applied slight circular force onto the sclera allowing the relaxation of the zonules. The shift of focus was demonstrated by using a reading target. In addition, viscoelastic was injected into the vitreous resulting in the same anterior movement of the IOL optic. The 1CU Humanoptics accommodative IOL showed potential accommodative behaviour in the laboratory. The accommodative (respectively pseudoaccommodative) effect was based on the anterior shift principle with anterior movement of the IOL-optic in the state of relaxing zonules. Whether this reflects the clinical situation, especially to this extent, must be further evaluated.

  4. "I Don't Know" and Multiple Choice Analysis of Pre- and Post-Tests

    ERIC Educational Resources Information Center

    Spears, Karen; Wilson, Mary

    2010-01-01

    Evaluation is an essential component of any Extension education program. One tool, the pre- and post-test, provides measurable evaluation data. Yet often the answer "I don't know" or all possible answers to a multiple choice question are not included in the repeated measure analysis. Because more than two answers are offered, the test of marginal…

  5. Results of the first provisional technical secretariat interlaboratory comparison test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stuff, J.R.; Hoffland, L.

    1995-06-01

    The principal task of this laboratory in the first Provisional Technical Secretariat (PTS) Interlaboratory Comparison Test was to verify and test the extraction and preparation procedures outlined in the Recommended Operating Procedures for Sampling and Analysis in the Verification of Chemical Disarmament in addition to our laboratory extraction methods and our laboratory analysis methods. Sample preparation began on 16 May 1994 and analysis was completed on 12 June 1994. The analytical methods used included NMR ({sup 1}H and {sup 31}P) GC/AED, GC/MS (EI and methane CI), GC/IRD, HPLC/IC, HPLC/TSP/MS, MS/MS(Electrospray), and CZE.

  6. 29 CFR 1910.1020 - Access to employee exposure and medical records.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... results of medical examinations (pre-employment, pre-assignment, periodic, or episodic) and laboratory tests (including chest and other X-ray examinations taken for the purposes of establishing a base-line...), the employer shall prominently post a copy of the written access order and its accompanying cover...

  7. 29 CFR 1910.1020 - Access to employee exposure and medical records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... results of medical examinations (pre-employment, pre-assignment, periodic, or episodic) and laboratory tests (including chest and other X-ray examinations taken for the purposes of establishing a base-line...), the employer shall prominently post a copy of the written access order and its accompanying cover...

  8. 29 CFR 1910.1020 - Access to employee exposure and medical records.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... results of medical examinations (pre-employment, pre-assignment, periodic, or episodic) and laboratory tests (including chest and other X-ray examinations taken for the purposes of establishing a base-line...), the employer shall prominently post a copy of the written access order and its accompanying cover...

  9. Adaptive Value of Phenological Traits in Stressful Environments: Predictions Based on Seed Production and Laboratory Natural Selection

    PubMed Central

    Glorieux, Cédric; Cuguen, Joel; Roux, Fabrice

    2012-01-01

    Phenological traits often show variation within and among natural populations of annual plants. Nevertheless, the adaptive value of post-anthesis traits is seldom tested. In this study, we estimated the adaptive values of pre- and post-anthesis traits in two stressful environments (water stress and interspecific competition), using the selfing annual species Arabidopsis thaliana. By estimating seed production and by performing laboratory natural selection (LNS), we assessed the strength and nature (directional, disruptive and stabilizing) of selection acting on phenological traits in A. thaliana under the two tested stress conditions, each with four intensities. Both the type of stress and its intensity affected the strength and nature of selection, as did genetic constraints among phenological traits. Under water stress, both experimental approaches demonstrated directional selection for a shorter life cycle, although bolting time imposes a genetic constraint on the length of the interval between bolting and anthesis. Under interspecific competition, results from the two experimental approaches showed discrepancies. Estimation of seed production predicted directional selection toward early pre-anthesis traits and long post-anthesis periods. In contrast, the LNS approach suggested neutrality for all phenological traits. This study opens questions on adaptation in complex natural environment where many selective pressures act simultaneously. PMID:22403624

  10. 78 FR 3407 - Proposed Information Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-16

    ... technical assistance programs by administering pre- and post-test instruments to participants. CNCS will.... Frequency: Annually. Average Time Per Response: Five minutes for the pre-test and 5 minutes for the post... analysis of client satisfaction feedback with aggregations of post training-participant evaluations...

  11. Hydrocode predictions of collisional outcomes: Effects of target size

    NASA Technical Reports Server (NTRS)

    Ryan, Eileen V.; Asphaug, Erik; Melosh, H. J.

    1991-01-01

    Traditionally, laboratory impact experiments, designed to simulate asteroid collisions, attempted to establish a predictive capability for collisional outcomes given a particular set of initial conditions. Unfortunately, laboratory experiments are restricted to using targets considerably smaller than the modelled objects. It is therefore necessary to develop some methodology for extrapolating the extensive experimental results to the size regime of interest. Results are reported obtained through the use of two dimensional hydrocode based on 2-D SALE and modified to include strength effects and the fragmentation equations. The hydrocode was tested by comparing its predictions for post-impact fragment size distributions to those observed in laboratory impact experiments.

  12. Laboratory testing of extravascular body fluids in Croatia: a survey of the Working group for extravascular body fluids of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Kopcinovic, Lara Milevoj; Vogrinc, Zeljka; Kocijan, Irena; Culej, Jelena; Aralica, Merica; Jokic, Anja; Antoncic, Dragana; Bozovic, Marija

    2016-10-15

    We hypothesized that extravascular body fluid (EBF) analysis in Croatia is not harmonized and aimed to investigate preanalytical, analytical and postanalytical procedures used in EBF analysis in order to identify key aspects that should be addressed in future harmonization attempts. An anonymous online survey created to explore laboratory testing of EBF was sent to secondary, tertiary and private health care Medical Biochemistry Laboratories (MBLs) in Croatia. Statements were designed to address preanalytical, analytical and postanalytical procedures of cerebrospinal, pleural, peritoneal (ascites), pericardial, seminal, synovial, amniotic fluid and sweat. Participants were asked to declare the strength of agreement with proposed statements using a Likert scale. Mean scores for corresponding separate statements divided according to health care setting were calculated and compared. The survey response rate was 0.64 (58 / 90). None of the participating private MBLs declared to analyse EBF. We report a mean score of 3.45 obtained for all statements evaluated. Deviations from desirable procedures were demonstrated in all EBF testing phases. Minor differences in procedures used for EBF analysis comparing secondary and tertiary health care MBLs were found. The lowest scores were obtained for statements regarding quality control procedures in EBF analysis, participation in proficiency testing programmes and provision of interpretative comments on EBF's test reports. Although good laboratory EBF practice is present in Croatia, procedures for EBF analysis should be further harmonized to improve the quality of EBF testing and patient safety.

  13. Destructive Physical Analysis of Flight- and Ground-Tested Sodium-Sulfur Cells

    NASA Technical Reports Server (NTRS)

    Wasz, Margot L.; Carter, Boyd J.; Donet, Charles M.; Baldwin, Richard S.

    1999-01-01

    Destructive physical analysis (DPA) was used to study the effects of microgravity on the sulfur electrode in sodium-sulfur cells. The cells examined in this work were provided by the Air Force Research Laboratory (AFRL) from their program on sodium-sulfur technology. The Naval Research Laboratory (NRL) provided electrical characterization of the flight-tested and ground-tested cells.

  14. Routine admission laboratory testing for general medical patients.

    PubMed

    Hubbell, F A; Frye, E B; Akin, B V; Rucker, L

    1988-06-01

    We evaluated the usefulness of commonly ordered routine admission laboratory tests in 301 patients admitted consecutively to the internal medicine wards of a university teaching hospital. Using a consensus analysis approach, three Department of Medicine faculty members reviewed the charts of admitted patients to determine the impact of the test results on patient care. The evaluated tests were the urinalysis, hematocrit, white blood cell count, platelet count, six-factor automated multiple analysis (serum sodium, potassium, chloride, bicarbonate, glucose, and blood urea nitrogen), prothrombin time, partial thromboplastin time, chest x-ray, and electrocardiogram. Forty-five percent of the 3,684 tests were ordered for patients without recognizable medical indications. Twelve percent of these routine tests were abnormal, 5% led to additional laboratory testing, but only 0.5% led to change in the treatment of patients. We conclude that the impact of routine admission laboratory testing on patient care is very small and that there is little justification for ordering tests solely because of hospital admission.

  15. Post-flight Analysis of Mars Science Laboratory Entry Aerothermal Environment and Thermal Protection System Response

    NASA Technical Reports Server (NTRS)

    White, Todd Richard; Mahazari, Milad; Bose, Deepak; Santos, Jose Antonio

    2013-01-01

    The Mars Science Laboratory successfully landed on the Martian surface on August 5th, 2012. The rover was protected from the extreme heating environments of atmospheric entry by an ablative heatshield. This Phenolic Impregnated Carbon Ablator heatshield was instrumented with a suite of embedded thermocouples, isotherm sensors, and pressure transducers. The sensors monitored the in-depth ablator response, as well as the surface pressure at discrete locations throughout the hypersonic deceleration. This paper presents a comparison of the flight data with post-entry estimates. An assessment of the aerothermal environments, as well as the in-depth response of the heatshield material is made, and conclusions regarding the overall performance of the ablator at the suite locations are presented.

  16. [What's the point of cost management in clinical laboratories?].

    PubMed

    Setoyama, Tomokazu; Yamauchi, Kazuyoshi; Katsuyama, Tsutomu

    2006-11-01

    Clinical laboratories need to know and manage the costs of laboratory tests, because they need financial data (1) to estimate costs per patient, (2) to request a budget to buy equipment, and (3) to improve their work; however, less than 40% laboratories practice cost management. In 2002, Shinshu University Hospital began to assess the costs of laboratory tests, but it was difficult to evaluate the quality of our cost management because there are few data and papers about the costs of laboratory tests in Japan. In this article, we practiced cost analysis using Shinshu University Hospital's data for 3 years (2002-2004), and studied the features of laboratory test costs and the problems of laboratory cost management. As a result, we listed 7 points to check cost management in clinical laboratories. This check list was established using only one data from our hospital. So, we suggest the benchmarking laboratory test costs between laboratories of the same type of hospitals or various laboratories.

  17. Post irradiation analysis of RERTR-7A, 7B and RERTR-8 tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hofman, G.L.; Kim, Yeon Soo; Shevlyakov, G.V.

    2008-07-15

    Addition of 2 wt% or more of silicon in the Al matrix for U-Mo/Al dispersion fuel has proved to be effective in reducing interaction layer growth from the RERTR-7A test to a burnup of {approx}100 at% U-235 (LEU equivalent). The recent RERTR-8 test also showed the consistent results. In this paper, we present the post irradiation analysis results of these tests. A considerable number of monolithic fuel plates were irradiated in the RERTR-7A and RERTR-8 tests. The post irradiation results of these plates are also included. The RERTR-7B test was a lower burnup test with similar power to the RERTR-7A.more » In this test, dispersion fuel plates with U-7Mo-1Ti and U- 7Mo-2Zr in Al-5Si were irradiated. The post irradiation results of these plates are also covered. (author)« less

  18. Creation of security engineering programs by the Southwest Surety Institute

    NASA Astrophysics Data System (ADS)

    Romero, Van D.; Rogers, Bradley; Winfree, Tim; Walsh, Dan; Garcia, Mary Lynn

    1998-12-01

    The Southwest Surety Institute includes Arizona State University (ASU), Louisiana State University (LSU), New Mexico Institute of Mining and Technology (NM Tech), New Mexico State University (NMSU), and Sandia National Laboratories (SNL). The universities currently offer a full spectrum of post-secondary programs in security system design and evaluation, including an undergraduate minor, a graduate program, and continuing education programs. The programs are based on the methodology developed at Sandia National Laboratories over the past 25 years to protect critical nuclear assets. The programs combine basic concepts and principles from business, criminal justice, and technology to create an integrated performance-based approach to security system design and analysis. Existing university capabilities in criminal justice (NMSU), explosives testing and technology (NM Tech and LSU), and engineering technology (ASU) are leveraged to provide unique science-based programs that will emphasize the use of performance measures and computer analysis tools to prove the effectiveness of proposed systems in the design phase. Facility managers may then balance increased protection against the cost of implementation and risk mitigation, thereby enabling effective business decisions. Applications expected to benefit from these programs include corrections, law enforcement, counter-terrorism, critical infrastructure protection, financial and medical care fraud, industrial security, and border security.

  19. [Survey results of medical insurance reimbursement system for independent medical laboratories in Korea].

    PubMed

    Bae, Sook Young; Kwon, Jung Ah; Kim, Jang Su; Yoon, Soo Young; Lee, Chang Kyu; Lee, Kap No; Kim, Dae Won; Min, Won Ki; Cha, Young Joo; Chae, Seok Lae; Hwang, Yoo Sung

    2007-04-01

    A questionnaire survey was performed to perceive the problem of the current medical insurance reimbursement system for laboratory tests referred to independent medical laboratories; then, we intended to find a way to improve the reimbursement system. Questionnaires were distributed to 220 independent medical laboratories and 700 laboratory physicians from July through October 2005. Frequency analysis was used to analyse the replies from 109 respondents to 25 questionnaire items regarding the current medical insurance reimbursement system for referral tests, problems with the system, and suggestions for the improvement of the system. Among the 109 respondents to this survey, 49 (45.8%) considered the current reimbursement system to be unsatisfactory, while only 16 (15.0%) answered satisfactory. The problem was that the referral clinics-not the laboratories that performed the tests--would first receive their reimbursement for the laboratory tests from Health Insurance Review Agency (HIRA) and then give a portion of the laboratory test fees to the independent medical laboratories after the deduction of administrative fees. They (62.5% of the respondents) would prefer a separated reimbursement system by which the referral clinic-as well as the independent medical laboratory-would receive their reimbursement directly from HIRA through an Electronic Data Interchange (EDI) system. In this new system, 34% of the respondents expected the quality of the laboratory tests to be improved; however, 41.6% answered that the income of the referral clinic is expected to decrease. For the improvement of the medical insurance reimbursement system, the administrative fee for the referral clinic and the test fee for the independent medical laboratory should be reimbursed directly to the respective organizations. These changes could be made possible with the proper analysis of medical costs and the development of an effective EDI reimbursement system.

  20. An analysis of reference laboratory (send out) testing: an 8-year experience in a large academic medical center.

    PubMed

    MacMillan, Donna; Lewandrowski, Elizabeth; Lewandrowski, Kent

    2004-01-01

    Utilization of outside reference laboratories for selected laboratory testing is common in the United States. However, relatively little data exist in the literature describing the scope and impact of these services. In this study, we reviewed use of reference laboratory testing at the Massachusetts General Hospital, a large urban academic medical center in Boston, Massachusetts. A retrospective review of hospital and laboratory administrative records over an 8-year period from fiscal years (FY) 1995-2002. Over the 8 years studied, reference laboratory expenses increased 4.2-fold and totaled 12.4% of the total laboratory budget in FY 2002. Total reference laboratory test volume increased 4-fold to 68,328 tests in FY 2002 but represented only 1.06% of the total test volume in the hospital. The menu of reference laboratory tests comprised 946 tests (65.7% of the hospital test menu) compared to 494 (34.3%) of tests performed in house. The average unit cost of reference laboratory tests was essentially unchanged but was approximately 13 times greater than the average unit cost in the hospital laboratory. Much of the growth in reference laboratory cost can be attributed to the addition of new molecular, genetic, and microbiological assays. Four of the top 10 tests with the highest total cost in 2002 were molecular diagnostic tests that were recently added to the test menu. Reference laboratory testing comprises a major component of hospital clinical laboratory services. Although send out tests represent a small percentage of the total test volume, these services account for the majority of the hospital laboratory test menu and a disproportionate percentage of laboratory costs.

  1. Effects of Students' Pre- and Post-Laboratory Concept Maps on Students' Attitudes toward Chemistry Laboratory in University General Chemistry

    ERIC Educational Resources Information Center

    Kilic, Ziya; Kaya, Osman Nafiz; Dogan, Alev

    2004-01-01

    The purpose of this study was to investigate the effects of scientific discussions based on student-constructed pre- and post-laboratory concept maps on students' attitudes toward chemistry laboratory in the university general chemistry. As part of instruction, during the first four laboratory sessions, students were taught how to construct and…

  2. Quasi-experimental nonequivalent (pretest and posttest) control-group study of the effects of microcomputer-based laboratory systems on academic achievement in high school chemistry students at two South Carolina high schools

    NASA Astrophysics Data System (ADS)

    Venables, Jeffrey M.

    The literature on microcomputer-based laboratories (MBL) lacks quantitative studies that measure the effect of MBL on student achievement. The purpose of this study was to investigate the effect of MBL systems on the achievement of high school chemistry students. The first research question examined the effect of MBL systems on student achievement in high school chemistry laboratories. The second question analyzed the effect of MBL systems on the academic achievement of students of different genders, ethnicities, and socioeconomic backgrounds. This quasi-experimental quantitative research study evaluated the effects of MBL on student achievement in high school chemistry. The sample consisted of 124 college preparatory chemistry students at two high schools in a South Carolina school district. There were 42 participants in the experimental group and 82 participants in the control group. Both experimental and groups completed a pre- and post-test with MBL being the independent variable. The mean difference score for the experimental group was compared to that of the control group using an independent-measures t test and an analysis of variance. For the second research question, results were analyzed using a two-factor analysis of variance. Participant scores were broken down by gender, ethnicity, and socioeconomic status in order to identify potential differences. The results revealed no significant differences between the experimental and control groups, and no significant differences in effects of MBL on different segments of the population. Future studies should examine students using MBL for longer durations than one unit of study. As society continues to make technological advances, the effective assessment and implementation of technology resources for the classroom are becoming increasingly important.

  3. Structural Analysis and Test Comparison of a 20-Meter Inflation-Deployed Solar Sail

    NASA Technical Reports Server (NTRS)

    Sleight, David W.; Mann, Troy; Lichodziejewski, David; Derbes, Billy

    2006-01-01

    Under the direction of the NASA In-Space Propulsion Technology Office, the team of L Garde, NASA Jet Propulsion Laboratory, Ball Aerospace, and NASA Langley Research Center has been developing a scalable solar sail configuration to address NASA s future space propulsion needs. Prior to a flight experiment of a full-scale solar sail, a comprehensive test program was implemented to advance the technology readiness level of the solar sail design. These tests consisted of solar sail component, subsystem, and sub-scale system ground tests that simulated the aspects of the space environment such as vacuum and thermal conditions. In July 2005, a 20-m four-quadrant solar sail system test article was tested in the NASA Glenn Research Center s Space Power Facility to measure its static and dynamic structural responses. Key to the maturation of solar sail technology is the development of validated finite element analysis (FEA) models that can be used for design and analysis of solar sails. A major objective of the program was to utilize the test data to validate the FEA models simulating the solar sail ground tests. The FEA software, ABAQUS, was used to perform the structural analyses to simulate the ground tests performed on the 20-m solar sail test article. This paper presents the details of the FEA modeling, the structural analyses simulating the ground tests, and a comparison of the pretest and post-test analysis predictions with the ground test results for the 20-m solar sail system test article. The structural responses that are compared in the paper include load-deflection curves and natural frequencies for the beam structural assembly and static shape, natural frequencies, and mode shapes for the solar sail membrane. The analysis predictions were in reasonable agreement with the test data. Factors that precluded better correlation of the analyses and the tests were unmeasured initial conditions in the test set-up.

  4. The Propagation of Errors in Experimental Data Analysis: A Comparison of Pre-and Post-Test Designs

    ERIC Educational Resources Information Center

    Gorard, Stephen

    2013-01-01

    Experimental designs involving the randomization of cases to treatment and control groups are powerful and under-used in many areas of social science and social policy. This paper reminds readers of the pre-and post-test, and the post-test only, designs, before explaining briefly how measurement errors propagate according to error theory. The…

  5. Bayes’ theorem, the ROC diagram and reference values: Definition and use in clinical diagnosis

    PubMed Central

    Kallner, Anders

    2017-01-01

    Medicine is diagnosis, treatment and care. To diagnose is to consider the probability of the cause of discomfort experienced by the patient. The physician may face many options and all decisions are liable to uncertainty to some extent. The rational action is to perform selected tests and thereby increase the pre-test probability to reach a superior post-test probability of a particular option. To draw the right conclusions from a test, certain background information about the performance of the test is necessary. We set up a partially artificial dataset with measured results obtained from the laboratory information system and simulated diagnosis attached. The dataset is used to explore the use of contingency tables with a unique graphic design and software to establish and compare ROC graphs. The loss of information in the ROC curve is compensated by a cumulative data analysis (CDA) plot linked to a display of the efficiency and predictive values. A standard for the contingency table is suggested and the use of dynamic reference intervals discussed. PMID:29209139

  6. Emotion self-regulation, psychophysiological coherence, and test anxiety: results from an experiment using electrophysiological measures.

    PubMed

    Bradley, Raymond Trevor; McCraty, Rollin; Atkinson, Mike; Tomasino, Dana; Daugherty, Alane; Arguelles, Lourdes

    2010-12-01

    This study investigated the effects of a novel, classroom-based emotion self-regulation program (TestEdge) on measures of test anxiety, socioemotional function, test performance, and heart rate variability (HRV) in high school students. The program teaches students how to self-generate a specific psychophysiological state--psychophysiological coherence--which has been shown to improve nervous system function, emotional stability, and cognitive performance. Implemented as part of a larger study investigating the population of tenth grade students in two California high schools (N = 980), the research reported here was conducted as a controlled pre- and post-intervention laboratory experiment, using electrophysiological measures, on a random stratified sample of students from the intervention and control schools (N = 136). The Stroop color-word conflict test was used as the experiment's stimulus to simulate the stress of taking a high-stakes test, while continuous HRV recordings were gathered. The post-intervention electrophysiological results showed a pattern of improvement across all HRV measures, indicating that students who received the intervention program had learned how to better manage their emotions and to self-activate the psychophysiological coherence state under stressful conditions. Moreover, students with high test anxiety exhibited increased HRV and heart rhythm coherence even during a resting baseline condition (without conscious use of the program's techniques), suggesting that they had internalized the benefits of the intervention. Consistent with these results, students exhibited reduced test anxiety and reduced negative affect after the intervention. Finally, there is suggestive evidence from a matched-pairs analysis that reduced test anxiety and increased psychophysiological coherence appear to be directly associated with improved test performance--a finding consistent with evidence from the larger study.

  7. Effectiveness of a Constructivist Approach to Science Instruction for Prospective Elementary Teachers

    NASA Astrophysics Data System (ADS)

    Liang, Ling L.; Gabel, Dorothy L.

    2005-08-01

    This study examines the effectiveness of a new constructivist curriculum model (Powerful Ideas in Physical Science) in improving prospective teachers’ understanding of science concepts, in fostering a learning environment supporting conceptual understanding, and in promoting positive attitudes toward learning and teaching science and chemistry in particular. A non-equivalent pretest post-test control-group design was employed. Analysis of covariance and repeated-measures analyses of variance were performed to analyze the scores on concept tests and attitude surveys. Data from videotaped observations of laboratory sessions and interviews of prospective teachers were analyzed by employing a naturalistic inquiry method to provide insights into the process of science learning and teaching for the teacher trainees. The interpretations were made based on the findings that could be corroborated by both methodologies. Conclusions and limitations of the present study as well as recommendations for future implementation of constructivist science curriculum in general are also included.

  8. Validation of material point method for soil fluidisation analysis

    NASA Astrophysics Data System (ADS)

    Bolognin, Marco; Martinelli, Mario; Bakker, Klaas J.; Jonkman, Sebastiaan N.

    2017-06-01

    The main aim of this paper is to describe and analyse the modelling of vertical column tests that undergo fluidisation by the application of a hydraulic gradient. A recent advancement of the material point method (MPM), allows studying both stationary and non-stationary fluid flow while interacting with the solid phase. The fluidisation initiation and post-fluidisation processes of the soil will be investigated with an advanced MPM formulation (Double Point) in which the behavior of the solid and the liquid phase is evaluated separately, assigning to each of them a set of material points (MPs). The result of these simulations are compared to analytic solutions and measurements from laboratory experiments. This work is used as a benchmark test for the MPM double point formulation in the Anura3D software and to verify the feasibility of the software for possible future engineering applications.

  9. Changing molecular epidemiology of rotavirus infection after introduction of monovalent rotavirus vaccination in Scotland.

    PubMed

    Mukhopadhya, Indrani; Murdoch, Heather; Berry, Susan; Hunt, Alison; Iturriza-Gomara, Miren; Smith-Palmer, Alison; Cameron, J Claire; Hold, Georgina L

    2017-01-03

    Rotaviruses (RV) are the leading cause of gastroenteritis in children less than five years of age worldwide. Rotarix®, a live attenuated monovalent vaccine containing a RV strain of G1P[8] specificity has been included in the childhood immunisation schedule from June 2013 in Scotland. This study aimed to characterise the prevalent RV strains in Scotland before and after the introduction of the RV vaccine. RV positive faecal samples from Scottish virology laboratories covering the years 2012-2015 were genotyped. Viral RNA was extracted from faecal suspensions. VP7 and VP4 gene specific primers were used for multiplex hemi-nested PCRs and sequencing. Mann-Whitney U test and Chi-square test were used for statistical comparison. There was a decrease in RV positive samples from the Scottish virology laboratories from 7409 samples in the pre-vaccination years (2009-2013) to 760 in 2014-2015, with an annual reduction of RV infections by 74.4% (RR-3.95; 95%-CI, 3.53-4.42, p<0.001). 362 samples from the pre-vaccination period and 278 samples from the post-vaccination were genotyped. There was a drop in prevalence of G1P[8] strains (72.1%, 95%-CI, 67.42-76.33 to 15%, 95%-CI, 11.38-19.79) after introduction of the vaccine. In the post-vaccination period G2P[4] was the dominant strain in Scotland (21.9%, 95%-CI, 17.48-27.17) with increase in G9P[8] (12.9%, 95%-CI, 9.50-7.41), G12P[8] (12.2%, 95%-CI, 8.89-16.60) and G3P[8] (11.9%, 95%-CI, 8.58-16.20) infections. Phylogenetic analysis of the VP7 and VP4 genes showed no major differences between the pre and post-vaccination G1P[8] strains. This laboratory based surveillance study shows significant reduction in reported RV cases and a shift in proportion from G1P[8] to G2P[4] strains after introduction of RV vaccination in Scotland. The genotyping data from a subset of the total reported RV cases will be used to ascertain cross protection against strains and identify vaccine induced RV strain shifts in the years to come. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Good Laboratory Practices of Materials Testing at NASA White Sands Test Facility

    NASA Technical Reports Server (NTRS)

    Hirsch, David; Williams, James H.

    2005-01-01

    An approach to good laboratory practices of materials testing at NASA White Sands Test Facility is presented. The contents include: 1) Current approach; 2) Data analysis; and 3) Improvements sought by WSTF to enhance the diagnostic capability of existing methods.

  11. Integrated Data Collection Analysis (IDCA) program--KClO 4/Dodecane Mixture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of KClO 4 and dodecane—KClO 4/dodecane mixture. This material was selected because of the challenge of performing SSST testing of a mixture of solid and liquid materials. The mixture was found to: 1) be less sensitive to impact than RDX, and PETN, 2) less sensitive to friction than RDX and PETN, and 3) less sensitive to spark thanmore » RDX and PETN. The thermal analysis showed little or no exothermic features suggesting that the dodecane volatilized at low temperatures. A prominent endothermic feature was observed and assigned to a phase transition of KClO 4. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results are compared among the laboratories and then compared to historical data from various sources. The testing performers involved for the KClO 4/dodecane mixture are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when these testing variables cannot be made consistent.« less

  12. U.S. Navy Officer Attitudes on the Repeal of Don’t Ask, Don’t Tell

    DTIC Science & Technology

    2013-03-01

    military units; a pre- test / post - test quasi experiment; survey analysis; relevant media analysis of articles related to the repeal and published within...and 2010. The surveys revealed an increasing acceptance of gays in the Navy. The present study, conducted post - repeal, utilized the same NPS survey...and enlisted personnel. Further, the post -repeal effects on readiness should be monitored, particularly for fairness and potential harassment. The

  13. Laser Shearography Inspection of TPS (Thermal Protection System) Cork on RSRM (Reusable Solid Rocket Motors)

    NASA Technical Reports Server (NTRS)

    Lingbloom, Mike; Plaia, Jim; Newman, John

    2006-01-01

    Laser Shearography is a viable inspection method for detection of de-bonds and voids within the external TPS (thermal protection system) on to the Space Shuttle RSRM (reusable solid rocket motors). Cork samples with thicknesses up to 1 inch were tested at the LTI (Laser Technology Incorporated) laboratory using vacuum-applied stress in a vacuum chamber. The testing proved that the technology could detect cork to steel un-bonds using vacuum stress techniques in the laboratory environment. The next logical step was to inspect the TPS on a RSRM. Although detailed post flight inspection has confirmed that ATK Thiokol's cork bonding technique provides a reliable cork to case bond, due to the Space Shuttle Columbia incident there is a great interest in verifying bond-lines on the external TPS. This interest provided and opportunity to inspect a RSRM motor with Laser Shearography. This paper will describe the laboratory testing and RSRM testing that has been performed to date. Descriptions of the test equipment setup and techniques for data collection and detailed results will be given. The data from the test show that Laser Shearography is an effective technology and readily adaptable to inspect a RSRM.

  14. Factors affecting the cement-post interface.

    PubMed

    Zicari, F; De Munck, J; Scotti, R; Naert, I; Van Meerbeek, B

    2012-03-01

    To evaluate the effect of different factors on the push-out bond strength of glass fiber posts luted in simulated (standard) root canals using different composite cements. Three types of glass-fiber root-canal posts with a different matrix, namely an epoxy resin (RelyX post, 3M ESPE), a proprietary composite resin (FRC-Plus post, Ivoclar-Vivadent), and a methacrylate resin (GC post, GC), and three types of composite cements, namely an etch-and-rinse Bis-GMA-based (Variolink II, Ivoclar-Vivadent), a self-etch 10-MDP-based (Clearfil Esthetic Cement, Kuraray) and a self-adhesive (RelyX Unicem, 3M ESPE) cement, were tested. Posts were either left untreated (control), were treated with silane, or coated with silicated alumina particles (Cojet system, 3M ESPE). Posts were inserted up to 9-mm depth into composite CAD-CAM blocks (Paradigm, 3M ESPE) in order to solely test the strength of the cement-post interface, while excluding interference of the cement-dentin interface. After 1-week storage at 37 °C, three sections (coronal, middle, apical) of 2-mm thickness were subjected to a push-out bond-strength test. All three variables, namely the type of post, the composite cement and the post-surface pre-treatment, were found to significantly affect the push-out bond strength (p<0.001). Regarding the type of post, a significantly lower push-out bond strength was recorded for the FRC-Plus post (Ivoclar-Vivadent); regarding the composite cement, a significantly higher push-out bond strength was recorded for the self-adhesive cement Unicem (3M ESPE); and regarding the post-surface treatment, a significantly higher push-out bond strength was recorded when the post-surface was beforehand subjected to a Cojet (3M ESPE) combined sandblasting/silicatization surface pre-treatment. Many interactions between these three variables were found to be significant as well (p<0.001). Finally, the push-out bond strength was found to significantly reduce with depth from coronal to apical. Laboratory testing revealed that different variables like the type of post, the composite cement and the post-surface pre-treatment may influence the cement-post interface, making clear guidelines for routine clinical practice hard to define. Further long-term durability testing may help to clarify, and should therefore be encouraged. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  15. Integrated Data Collection Analysis (IDCA) Program - KClO 4/Carbon Mixture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of KClO 4 and activated carbon—KClO 4/C mixture. This material was selected because of the challenge of performing SSST testing of a mixture of two solids. The mixture was found to be insensitive to impact, friction, and thermal stimulus, and somewhat sensitive to spark discharge. This effort, funded by the Department of Homeland Security (DHS), ultimately will putmore » the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results are compared among the laboratories and then compared to historical data from various sources. The testing performers involved for the KClO 4/carbon mixture are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when these testing variables cannot be made consistent.« less

  16. Modeling Canadian Quality Control Test Program for Steroid Hormone Receptors in Breast Cancer: Diagnostic Accuracy Study.

    PubMed

    Pérez, Teresa; Makrestsov, Nikita; Garatt, John; Torlakovic, Emina; Gilks, C Blake; Mallett, Susan

    The Canadian Immunohistochemistry Quality Control program monitors clinical laboratory performance for estrogen receptor and progesterone receptor tests used in breast cancer treatment management in Canada. Current methods assess sensitivity and specificity at each time point, compared with a reference standard. We investigate alternative performance analysis methods to enhance the quality assessment. We used 3 methods of analysis: meta-analysis of sensitivity and specificity of each laboratory across all time points; sensitivity and specificity at each time point for each laboratory; and fitting models for repeated measurements to examine differences between laboratories adjusted by test and time point. Results show 88 laboratories participated in quality control at up to 13 time points using typically 37 to 54 histology samples. In meta-analysis across all time points no laboratories have sensitivity or specificity below 80%. Current methods, presenting sensitivity and specificity separately for each run, result in wide 95% confidence intervals, typically spanning 15% to 30%. Models of a single diagnostic outcome demonstrated that 82% to 100% of laboratories had no difference to reference standard for estrogen receptor and 75% to 100% for progesterone receptor, with the exception of 1 progesterone receptor run. Laboratories with significant differences to reference standard identified with Generalized Estimating Equation modeling also have reduced performance by meta-analysis across all time points. The Canadian Immunohistochemistry Quality Control program has a good design, and with this modeling approach has sufficient precision to measure performance at each time point and allow laboratories with a significantly lower performance to be targeted for advice.

  17. Feasibility of establishing a biosafety level 3 tuberculosis culture laboratory of acceptable quality standards in a resource-limited setting: an experience from Uganda.

    PubMed

    Ssengooba, Willy; Gelderbloem, Sebastian J; Mboowa, Gerald; Wajja, Anne; Namaganda, Carolyn; Musoke, Philippa; Mayanja-Kizza, Harriet; Joloba, Moses Lutaakome

    2015-01-15

    Despite the recent innovations in tuberculosis (TB) and multi-drug resistant TB (MDR-TB) diagnosis, culture remains vital for difficult-to-diagnose patients, baseline and end-point determination for novel vaccines and drug trials. Herein, we share our experience of establishing a BSL-3 culture facility in Uganda as well as 3-years performance indicators and post-TB vaccine trials (pioneer) and funding experience of sustaining such a facility. Between September 2008 and April 2009, the laboratory was set-up with financial support from external partners. After an initial procedure validation phase in parallel with the National TB Reference Laboratory (NTRL) and legal approvals, the laboratory registered for external quality assessment (EQA) from the NTRL, WHO, National Health Laboratories Services (NHLS), and the College of American Pathologists (CAP). The laboratory also instituted a functional quality management system (QMS). Pioneer funding ended in 2012 and the laboratory remained in self-sustainability mode. The laboratory achieved internationally acceptable standards in both structural and biosafety requirements. Of the 14 patient samples analyzed in the procedural validation phase, agreement for all tests with NTRL was 90% (P <0.01). It started full operations in October 2009 performing smear microscopy, culture, identification, and drug susceptibility testing (DST). The annual culture workload was 7,636, 10,242, and 2,712 inoculations for the years 2010, 2011, and 2012, respectively. Other performance indicators of TB culture laboratories were also monitored. Scores from EQA panels included smear microscopy >80% in all years from NTRL, CAP, and NHLS, and culture was 100% for CAP panels and above regional average scores for all years with NHLS. Quarterly DST scores from WHO-EQA ranged from 78% to 100% in 2010, 80% to 100% in 2011, and 90 to 100% in 2012. From our experience, it is feasible to set-up a BSL-3 TB culture laboratory with acceptable quality performance standards in resource-limited countries. With the demonstrated quality of work, the laboratory attracted more research groups and post-pioneer funding, which helped to ensure sustainability. The high skilled experts in this research laboratory also continue to provide an excellent resource for the needed national discussion of the laboratory and quality management systems.

  18. Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testingmore » by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.« less

  19. Evaluating the efficacy of a chemistry video game

    NASA Astrophysics Data System (ADS)

    Shapiro, Marina

    A quasi-experimental design pre-test/post-test intervention study utilizing a within group analysis was conducted with 45 undergraduate college chemistry students that investigated the effect of implementing a game-based learning environment into an undergraduate college chemistry course in order to learn if serious educational games (SEGs) can be used to achieve knowledge gains of complex chemistry concepts and to achieve increase in students' positive attitude toward chemistry. To evaluate if students learn chemistry concepts by participating in a chemistry game-based learning environment, a one-way repeated measures analysis of variance (ANOVA) was conducted across three time points (pre-test, post-test, delayed post-test which were chemistry content exams). Results showed that there was an increase in exam scores over time. The results of the ANOVA indicated a statistically significant time effect. To evaluate if students' attitude towards chemistry increased as a result of participating in a chemistry game-based learning environment a paired samples t-test was conducted using a chemistry attitudinal survey by Mahdi (2014) as the pre- and post-test. Results of the paired-samples t-test indicated that there was no significant difference in pre-attitudinal scores and post-attitudinal scores.

  20. About Rubella (German Measles, Three-Day Measles)

    MedlinePlus

    ... Professionals Pregnancy and Rubella Rubella Vaccination Travelers’ Health Information on Rubella Laboratory Testing CDC Laboratory Testing & Procedures Serology RNA Detection Genetic Analysis Specimen Collection, Storage, & Shipment Sample Submission Q&A ...

  1. Rubella (German Measles, Three-Day Measles) Photos

    MedlinePlus

    ... Professionals Pregnancy and Rubella Rubella Vaccination Travelers’ Health Information on Rubella Laboratory Testing CDC Laboratory Testing & Procedures Serology RNA Detection Genetic Analysis Specimen Collection, Storage, & Shipment Sample Submission Q&A ...

  2. Correlation of KIT and PDGFRA mutational status with clinical benefit in patients with gastrointestinal stromal tumor treated with sunitinib in a worldwide treatment-use trial.

    PubMed

    Reichardt, Peter; Demetri, George D; Gelderblom, Hans; Rutkowski, Piotr; Im, Seock-Ah; Gupta, Sudeep; Kang, Yoon-Koo; Schöffski, Patrick; Schuette, Jochen; Soulières, Denis; Blay, Jean-Yves; Goldstein, David; Fly, Kolette; Huang, Xin; Corsaro, Massimo; Lechuga, Maria Jose; Martini, Jean-Francois; Heinrich, Michael C

    2016-01-15

    Several small studies indicated that the genotype of KIT or platelet-derived growth factor receptor-α (PDGFRA) contributes in part to the level of clinical effectiveness of sunitinib in gastrointestinal stromal tumor (GIST) patients. This study aimed to correlate KIT and PDGFRA mutational status with clinical outcome metrics (progression-free survival [PFS], overall survival [OS], objective response rate [ORR]) in a larger international patient population. This is a non-interventional, retrospective analysis in patients with imatinib-resistant or intolerant GIST who were treated in a worldwide, open-label treatment-use study (Study 1036; NCT00094029) in which sunitinib was administered at a starting dose of 50 mg/day on a 4-week-on, 2-week-off schedule. Molecular status was obtained in local laboratories with tumor samples obtained either pre-imatinib, post-imatinib/pre-sunitinib, or post-sunitinib treatment, and all available data were used in the analyses regardless of collection time. The primary analysis compared PFS in patients with primary KIT exon 11 versus exon 9 mutations (using a 2-sided log-rank test) and secondary analyses compared OS (using the same test) and ORR (using a 2-sided Pearson χ(2) test) in the same molecular subgroups. Of the 1124 sunitinib-treated patients in the treatment-use study, 230 (20%) were included in this analysis, and baseline characteristics were similar between the two study populations. Median PFS was 7.1 months. A significantly better PFS was observed in patients with a primary mutation in KIT exon 9 (n = 42) compared to those with a primary mutation in exon 11 (n = 143; hazard ratio = 0.59; 95 % confidence interval, 0.39-0.89; P = 0.011), with median PFS times of 12.3 and 7.0 months, respectively. Similarly, longer OS and higher ORR were observed in patients with a primary KIT mutation in exon 9 versus exon 11. The data available were limited to investigate the effects of additional KIT or PDGFRA mutations on the efficacy of sunitinib treatment. This large retrospective analysis confirms the prognostic significance of KIT mutation status in patients with GIST. This analysis also confirms the effectiveness of sunitinib as a post-imatinib therapy, regardless of mutational status. NCT01459757.

  3. 76 FR 63615 - Environmental Science Center Microbiology Laboratory; Notice of Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-13

    ...-dilution method (UDM) and the status and implementation of a new test method, the Organization for Economic... using the method for registration purposes, the method is currently in use as part of the post market... associated with the S. aureus and P. aeruginosa methodologies, which are designed to further optimize and...

  4. An Extended Kalman filter (EKF) for Mars Exploration Rover (MER) entry, descent, and landing reconstruction

    NASA Technical Reports Server (NTRS)

    Lisano, M. E.

    2003-01-01

    This paper describes the design and initial test results of an extended Kalman filter that has been developed at Jet Propulsion Laboratory (JPL) for post-flight reconstruction of the trajectory and attitude history of a spacecraft entering a planetary atmosphere and descending upon a parachute.

  5. The Influence of PBL on Students' Self-Efficacy Beliefs in Chemistry

    ERIC Educational Resources Information Center

    Mataka, Lloyd M.; Grunert Kowalske, Megan

    2015-01-01

    A convergent mixed methods research study was used to investigate whether or not undergraduate students who participated in a problem-based learning (PBL) laboratory environment improved their self-efficacy beliefs in chemistry. The Chemistry Attitude and Experience Questionnaire (CAEQ) was used as a pre- and post-test to determine changes in…

  6. Filtrates and Residues: Qualitative Analysis of Some Transition Metals.

    ERIC Educational Resources Information Center

    Kilner, Cary

    1985-01-01

    Describes a qualitative analysis laboratory in which students examine specific precipitates that can be used to identify copper, cobalt, nickel, and iron cations. The objective of the laboratory is to determine which test or sequence of tests unambiguously identifies each cation and to use the results to identify several unknowns. (JN)

  7. 7 CFR 91.38 - Additional fees for appeal of analysis.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.38 Additional fees for appeal of analysis. (a) The applicant for appeal sample testing will be charged a fee at the hourly rate for laboratory service that appears in this paragraph. The new fiscal year for Science and Technology...

  8. 7 CFR 91.38 - Additional fees for appeal of analysis.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.38 Additional fees for appeal of analysis. (a) The applicant for appeal sample testing will be charged a fee at the hourly rate for laboratory service that appears in this paragraph. The new fiscal year for Science and Technology...

  9. 7 CFR 91.38 - Additional fees for appeal of analysis.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.38 Additional fees for appeal of analysis. (a) The applicant for appeal sample testing will be charged a fee at the hourly rate for laboratory service that appears in this paragraph. The new fiscal year for Science and Technology...

  10. Evaluation of Hepatitis A Vaccine in Post-Exposure Prophylaxis, The Netherlands, 2004-2012

    PubMed Central

    Whelan, Jane; Sonder, Gerard J.; Bovée, Lian; Speksnijder, Arjen; van den Hoek, Anneke

    2013-01-01

    Background The secondary attack rate of hepatitis A virus (HAV) among contacts of cases is up to 50%. Historically, contacts were offered immunoglobulin (IG, a human derived blood product) as post-exposure prophylaxis (PEP). Amid safety concerns about IG, HAV vaccine is increasingly recommended instead. Public health authorities’ recommendations differ, particularly for healthy contacts ≥40 years old, where vaccine efficacy data is limited. We evaluated routine use of HAV vaccine as an alternative to immunoglobulin in PEP, in those considered at low risk of severe infection in the Netherlands. Methods Household contacts of acute HAV cases notified in Amsterdam (2004-2012) were invited ≤14 days post-exposure, for baseline anti-HAV testing and PEP according to national guidelines: immunoglobulin if at risk of severe infection, or hepatitis A vaccine if healthy and at low risk (aged <30, or, 30-50 years and vaccinated <8 days post-exposure). Incidence of laboratory confirmed secondary infection in susceptible contacts was assessed 4-8 weeks post-exposure. In a vaccinated subgroup, relative risk (RR) of secondary infection with estimated using Poisson regression. Results Of 547 contacts identified, 191 were susceptible to HAV. Per-protocol, 167 (87%) were vaccinated (mean:6.7 days post-exposure, standard deviation(sd)=3.3) and 24 (13%) were given immunoglobulin (mean:9.7 days post-exposure, sd=2.8). At follow-up testing, 8/112 (7%) had a laboratory confirmed infection of whom 7 were symptomatic. All secondary infections occurred in vaccinated contacts, and half were >40 years of age. In healthy contacts vaccinated per-protocol ≤8 days post-exposure, RRref. ≤15 years of secondary infection in those >40 years was 12.0 (95%CI:1.3-106.7). Conclusions Timely administration of HAV vaccine in PEP was feasible and the secondary attack rate was low in those <40 years. Internationally, upper age-limits for post-exposure vaccination vary. Pending larger studies, immunoglobulin should be considered PEP of choice in people >40 years of age and those vulnerable to severe disease. PMID:24147144

  11. Artificial neural network predictions of lengths of stay on a post-coronary care unit.

    PubMed

    Mobley, B A; Leasure, R; Davidson, L

    1995-01-01

    To create and validate a model that predicts length of hospital unit stay. Ex post facto. Seventy-four independent admission variables in 15 general categories were utilized to predict possible stays of 1 to 20 days. Laboratory. Records of patients discharged from a post-coronary care unit in early 1993. An artificial neural network was trained on 629 records and tested on an additional 127 records of patients. The absolute disparity between the actual lengths of stays in the test records and the predictions of the network averaged 1.4 days per record, and the actual length of stay was predicted within 1 day 72% of the time. The artificial neural network demonstrated the capacity to utilize common patient admission characteristics to predict lengths of stay. This technology shows promise in aiding timely initiation of treatment and effective resource planning and cost control.

  12. Institutional practices and policies in acid-base testing: a self reported Croatian survey study on behalf of the Croatian society of medical biochemistry and laboratory medicine Working Group for acid-base balance.

    PubMed

    Dukić, Lora; Simundić, Ana-Maria

    2014-01-01

    The aim of this survey study was to assess the current practices and policies in use related to the various steps in the blood gas testing process, across hospital laboratories in Croatia. First questionnaire was sent by email to all medical biochemistry laboratories (N = 104) within general, specialized and clinical hospitals and university hospital centres to identify laboratories which perform blood gas analysis. Second questionnaire with detailed questions about sample collection, analysis and quality control procedures, was sent only to 47 laboratories identified by the first survey. Questionnaire was designed as combination of questions and statements with Likert scale. Third questionnaire was sent to all participating laboratories (N=47) for additional clarification for either indeterminate or unclear answers. Blood gas analysis is performed in 47/104 hospital laboratories in Croatia. In 25/41 (0.61) of the laboratories capillary blood gas sampling is the preferred sample type for adult patient population, whereas arterial blood sample is preferentially used in only 5/44 laboratories (0.11). Blood sampling and sample processing for capillary samples is done almost always by laboratory technicians (36/41 and 37/44, respectively), whereas arterial blood sampling is almost always done by the physician (24/29) and only rarely by a nurse (5/28). Sample acceptance criteria and sample analysis are in accordance with international recommendations for majority of laboratories. 43/44 laboratories participate in the national EQA program. POCT analyzers are installed outside of the laboratory in 20/47 (0.43) institutions. Laboratory staff is responsible for education and training of ward personnel, quality control and instrument maintenance in only 12/22, 11/20 and 9/20 institutions, respectively. Practices related to collection and analysis for blood gases in Croatia are not standardised and vary substantially between laboratories. POCT analyzers are not under the direct supervision by laboratory personnel in a large proportion of surveyed institutions. Collective efforts should be made to harmonize and improve policies and procedures related to blood gas testing in Croatian laboratories.

  13. The Synthetic Experiment: E. B. Titchener's Cornell Psychological Laboratory and the Test of Introspective Analysis.

    PubMed

    Evans, Rand B

    2017-01-01

    Beginning in 1 9a0, a major thread of research was added to E. B. Titchener's Cornell laboratory: the synthetic experiment. Titchener and his graduate students used introspective analysis to reduce a perception, a complex experience, into its simple sensory constituents. To test the validity of that analysis, stimulus patterns were selected to reprodiuce the patterns of sensations found in the introspective analyses. If the original perception can be reconstructed in this way, then the analysis was considered validated. This article reviews development of the synthetic method in E. B. Titchener's laboratory at Cornell University and examines its impact on psychological research.

  14. Laboratory testing of extravascular body fluids in Croatia: a survey of the Working group for extravascular body fluids of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Kopcinovic, Lara Milevoj; Vogrinc, Zeljka; Kocijan, Irena; Culej, Jelena; Aralica, Merica; Jokic, Anja; Antoncic, Dragana; Bozovic, Marija

    2016-01-01

    Introduction We hypothesized that extravascular body fluid (EBF) analysis in Croatia is not harmonized and aimed to investigate preanalytical, analytical and postanalytical procedures used in EBF analysis in order to identify key aspects that should be addressed in future harmonization attempts. Materials and methods An anonymous online survey created to explore laboratory testing of EBF was sent to secondary, tertiary and private health care Medical Biochemistry Laboratories (MBLs) in Croatia. Statements were designed to address preanalytical, analytical and postanalytical procedures of cerebrospinal, pleural, peritoneal (ascites), pericardial, seminal, synovial, amniotic fluid and sweat. Participants were asked to declare the strength of agreement with proposed statements using a Likert scale. Mean scores for corresponding separate statements divided according to health care setting were calculated and compared. Results The survey response rate was 0.64 (58 / 90). None of the participating private MBLs declared to analyse EBF. We report a mean score of 3.45 obtained for all statements evaluated. Deviations from desirable procedures were demonstrated in all EBF testing phases. Minor differences in procedures used for EBF analysis comparing secondary and tertiary health care MBLs were found. The lowest scores were obtained for statements regarding quality control procedures in EBF analysis, participation in proficiency testing programmes and provision of interpretative comments on EBF’s test reports. Conclusions Although good laboratory EBF practice is present in Croatia, procedures for EBF analysis should be further harmonized to improve the quality of EBF testing and patient safety. PMID:27812307

  15. Empirical and Face Validity of Software Maintenance Defect Models Used at the Jet Propulsion Laboratory

    NASA Technical Reports Server (NTRS)

    Taber, William; Port, Dan

    2014-01-01

    At the Mission Design and Navigation Software Group at the Jet Propulsion Laboratory we make use of finite exponential based defect models to aid in maintenance planning and management for our widely used critical systems. However a number of pragmatic issues arise when applying defect models for a post-release system in continuous use. These include: how to utilize information from problem reports rather than testing to drive defect discovery and removal effort, practical model calibration, and alignment of model assumptions with our environment.

  16. Creep-Fatigue Failure Diagnosis

    PubMed Central

    Holdsworth, Stuart

    2015-01-01

    Failure diagnosis invariably involves consideration of both associated material condition and the results of a mechanical analysis of prior operating history. This Review focuses on these aspects with particular reference to creep-fatigue failure diagnosis. Creep-fatigue cracking can be due to a spectrum of loading conditions ranging from pure cyclic to mainly steady loading with infrequent off-load transients. These require a range of mechanical analysis approaches, a number of which are reviewed. The microstructural information revealing material condition can vary with alloy class. In practice, the detail of the consequent cracking mechanism(s) can be camouflaged by oxidation at high temperatures, although the presence of oxide on fracture surfaces can be used to date events leading to failure. Routine laboratory specimen post-test examination is strongly recommended to characterise the detail of deformation and damage accumulation under known and well-controlled loading conditions to improve the effectiveness and efficiency of failure diagnosis. PMID:28793676

  17. Analysis on pile testing results of post-grouting bored pile

    NASA Astrophysics Data System (ADS)

    Zheng, A. R.

    2017-04-01

    Based on static load test results, the bearing capacity of bored piles with pile-toe and pile-shaft post-grouting has been analyzed. The analysis reveals that: with post-grouting, the interface between pile and surrounding soil are strengthened and the relative sliding displacement in between is reduced; end resistance of pile is enhanced and can be mobilized at earlier stage with smaller sliding displacement. As a result, the performance of bored pile is improved with increased bearing capacity and reduced settlement.

  18. Time devoted to pre- and post-HIV test counselling in different health services according to participants of a rapid testing program in Madrid, Spain.

    PubMed

    Hoyos Miller, Juan; Fernández-Balbuena, Sonia; Belza Egozcue, María José; García de Olalla, Patricia; Pulido Manzanero, Jose; Molist Señe, Gemma; de la Fuente de Hoz, Luis

    2014-02-01

    The role of pre- and post-test counselling in new HIV testing strategies to reduce delayed diagnosis has been debated. Data on time devoted to counselling are scarce. One approach to this problem is to explore patients' views on the time devoted to counselling by venue of their last HIV test. We analysed data from 1568 people with a previous HIV test who attended a mobile HIV testing program in Madrid between May and December 2008. The majority (71%) were men (48% had had sex with other men), 51% were <30 years, 40% were foreigners, 56% had a university degree, and 40% had the most recent HIV test within the last year. As regards pre-test counselling, 30% stated they were told only that they would receive the test; 26.3% reported <10 min; 20.4% about 10 min; and 24.2%, 15 min or more. For post-test counselling: 40.2% stated they were told only that the test was negative; 24.9% reported 2-6 min; 16.4% about 10 min; and 18.5%, 15 min or more. The percentage of participants who reported no counselling time was higher among those tested in general health services: primary care, hospital settings and private laboratories (over 40% in pre-test, over 50% in post-test counselling). Women received less counselling time than men in almost all settings. Policies to expand HIV testing in general health services should take this current medical behaviour into account. Any mention of the need for counselling can be a barrier to expansion, because HIV is becoming less of a priority in developed countries. Oral consent should be the only requirement. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  19. Task-based learning versus problem-oriented lecture in neurology continuing medical education.

    PubMed

    Vakani, Farhan; Jafri, Wasim; Ahmad, Amina; Sonawalla, Aziz; Sheerani, Mughis

    2014-01-01

    To determine whether general practitioners learned better with task-based learning or problem-oriented lecture in a Continuing Medical Education (CME) set-up. Quasi-experimental study. The Aga Khan University, Karachi campus, from April to June 2012. Fifty-nine physicians were given a choice to opt for either Task-based Learning (TBL) or Problem Oriented Lecture (PBL) in a continuing medical education set-up about headaches. The TBL group had 30 participants divided into 10 small groups, and were assigned case-based tasks. The lecture group had 29 participants. Both groups were given a pre and a post-test. Pre/post assessment was done using one-best MCQs. The reliability coefficient of scores for both the groups was estimated through Cronbach's alpha. An item analysis for difficulty and discriminatory indices was calculated for both the groups. Paired t-test was used to determine the difference between pre- and post-test scores of both groups. Independent t-test was used to compare the impact of the two teaching methods in terms of learning through scores produced by MCQ test. Cronbach's alpha was 0.672 for the lecture group and 0.881 for TBL group. Item analysis for difficulty (p) and discriminatory indexes (d) was obtained for both groups. The results for the lecture group showed pre-test (p) = 42% vs. post-test (p) = 43%; pre- test (d) = 0.60 vs. post-test (d) = 0.40. The TBL group showed pre -test (p) = 48% vs. post-test (p) = 70%; pre-test (d) = 0.69 vs. post-test (d) = 0.73. Lecture group pre-/post-test mean scores were (8.52 ± 2.95 vs. 12.41 ± 2.65; p < 0.001), where TBL group showed (9.70 ± 3.65 vs. 14 ± 3.99; p < 0.001). Independent t-test exhibited an insignificant difference at baseline (lecture 8.52 ± 2.95 vs. TBL 9.70 ± 3.65; p = 0.177). The post-scores were not statistically different lecture 12.41 ± 2.65 vs. TBL 14 ± 3.99; p = 0.07). Both delivery methods were found to be equally effective, showing statistically insignificant differences. However, TBL groups' post-test higher mean scores and radical increase in the post-test difficulty index demonstrated improved learning through TBL delivery and calls for further exploration of longitudinal studies in the context of CME.

  20. Perchlorate in Fertilizers

    DTIC Science & Technology

    1999-09-01

    Harrington , showed that with respect to mixed water analysis containing TDS at greater 1,000 ppm, the performance of the AS-5 column is not as robust...to note, these raw test materials were heterogeneous. Regardless of mixing time and mesh quality, dividing the raw test materials for laboratory...raw test material was prepared and shipped to seven laboratories for blind analysis. The suspension was prepared by 4 mixing the solid sample with

  1. In-flight radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

    NASA Technical Reports Server (NTRS)

    Conel, James E.; Green, Robert O.; Alley, Ronald E.; Bruegge, Carol J.; Carrere, Veronique; Margolis, Jack S.; Vane, Gregg; Chrien, Thomas G.; Slater, Philip N.; Biggard, Stuart F.

    1988-01-01

    A reflectance-based method was used to provide an analysis of the in-flight radiometric performance of AVIRIS. Field spectral reflectance measurements of the surface and extinction measurements of the atmosphere using solar radiation were used as input to atmospheric radiative transfer calculations. Five separate codes were used in the analysis. Four include multiple scattering, and the computed radiances from these for flight conditions were in good agreement. Code-generated radiances were compared with AVIRIS-predicted radiances based on two laboratory calibrations (pre- and post-season of flight) for a uniform highly reflecting natural dry lake target. For one spectrometer (C), the pre- and post-season calibration factors were found to give identical results, and to be in agreement with the atmospheric models that include multiple scattering. This positive result validates the field and laboratory calibration technique. Results for the other spectrometers (A, B and D) were widely at variance with the models no matter which calibration factors were used. Potential causes of these discrepancies are discussed.

  2. Validation of the Physics Analysis used to Characterize the AGR-1 TRISO Fuel Irradiation Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sterbentz, James W.; Harp, Jason M.; Demkowicz, Paul A.

    2015-05-01

    The results of a detailed physics depletion calculation used to characterize the AGR-1 TRISO-coated particle fuel test irradiated in the Advanced Test Reactor (ATR) at the Idaho National Laboratory are compared to measured data for the purpose of validation. The particle fuel was irradiated for 13 ATR power cycles over three calendar years. The physics analysis predicts compact burnups ranging from 11.30-19.56% FIMA and cumulative neutron fast fluence from 2.21?4.39E+25 n/m 2 under simulated high-temperature gas-cooled reactor conditions in the ATR. The physics depletion calculation can provide a full characterization of all 72 irradiated TRISO-coated particle compacts during and post-irradiation,more » so validation of this physics calculation was a top priority. The validation of the physics analysis was done through comparisons with available measured experimental data which included: 1) high-resolution gamma scans for compact activity and burnup, 2) mass spectrometry for compact burnup, 3) flux wires for cumulative fast fluence, and 4) mass spectrometry for individual actinide and fission product concentrations. The measured data are generally in very good agreement with the calculated results, and therefore provide an adequate validation of the physics analysis and the results used to characterize the irradiated AGR-1 TRISO fuel.« less

  3. Integrated Data Collection Analysis (IDCA) Program - AN and Bullseye Smokeless Powder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of ammonium nitrate (AN) mixed with Bullseye® smokeless powder (Gunpowder). The participants found the AN/Gunpowder to: 1) have a range of sensitivity to impact, comparable to or less than RDX, 2) be fairly insensitive to friction as measured by BAM and ABL, 3) have a range for ESD, from insensitive to more sensitive than PETN, and 4) have thermal sensitivity aboutmore » the same as PETN and Gunpowder. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed when developing safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods. Note, however, the test procedures differ among the laboratories. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent. Keywords: Small-scale safety testing, proficiency test, impact-, friction-, spark discharge-, thermal testing, round-robin test, safety testing protocols, HME, RDX, potassium perchlorate, potassium chlorate, sodium chlorate, sugar, dodecane, PETN, carbon, ammonium nitrate, Gunpowder, Bullseye® smokeless powder.« less

  4. [Direct restoration of the tooth crown using various core build-up materials].

    PubMed

    Maksimovskaya, L N; Krutov, V A; Kuprin, P V; Kuprina, M A

    The aim of the study was to assess direct restorations mechanical properties (both in vitro and in vivo) to improve dental restorations quality after root canal treatment. Laboratory tests showed that using nanocomposite materials of dual curing with the fiberglass reinforced posts improves restoration strength in endodontically treated teeth: by 3.9±5.8% in class II Peroz restorations, 12.6±5.9 and 24.2±4.2% in class III and IV, correspondently. Using fiberglass reinforced posts (LuxaPost) for the restoration of the tooth crown after endodontic treatment significantly decreases the number of complications associated with marginal leakage of the restoration during first 2 years after treatment (p<005).

  5. Strategies to reduce inappropriate laboratory blood test orders in intensive care are effective and safe: a before-and-after quality improvement study.

    PubMed

    Dhanani, J A; Barnett, A G; Lipman, J; Reade, M C

    2018-05-01

    Unnecessary pathology tests performed in intensive care units (ICU) might lead to increased costs of care and potential patient harm due to unnecessary phlebotomy. We hypothesised that a multimodal intervention program could result in a safe and effective reduction in the pathology tests ordered in our ICU. We conducted a single-centre pre- and post-study using multimodal interventions to address commonly ordered routine tests. The study was performed during the same six month period (August to February) over three years: 2012 to 2013 (pre-intervention), 2013 to 2014 (intervention) and 2014 to 2015 (post-intervention). Interventions consisted of staff education, designing new pathology forms, consultant-led pathology test ordering and intensive monitoring for a six-month period. The results of the study showed that there was a net savings of over A$213,000 in the intervention period and A$175,000 in the post-intervention period compared to the pre-intervention period. There was a 28% reduction in the tests performed in the intervention period (P <0.0001 compared to pre-intervention period) and 26% in the post-intervention period (P <0.0001 compared to pre-intervention period). There were no ICU or hospital mortality differences between the groups. There were no significant haemoglobin differences between the groups. A multimodal intervention safely reduced pathology test ordering in the ICU, resulting in substantial cost savings.

  6. Practical methodological guide for hydrometric inter-laboratory organisation

    NASA Astrophysics Data System (ADS)

    Besson, David; Bertrand, Xavier

    2015-04-01

    Discharge measurements performed by the French governmental hydrometer team feed a national database. This data is available for general river flows knowkedge, flood forecasting, low water survey, statistical calculations flow, control flow regulatory and many other uses. Regularly checking the measurements quality and better quantifying its accuracy is therefore an absolute need. The practice of inter-laboratory comparison in hydrometry particularly developed during the last decade. Indeed, discharge measurement can not easily be linked to a standard. Therefore, on-site measurement accuracy control is very difficult. Inter-laboratory comparison is thus a practical solution to this issue. However, it needs some regulations in order to ease its practice and legitimize its results. To do so, the French government hydrometrics teams produced a practical methodological guide for hydrometric inter-laboratory organisation in destination of hydrometers community in view of ensure the harmonization of inter-laboratory comparison practices for different materials (ADCP, current meter on wadind rod or gauging van, tracer dilution, surface speed) and flow range (flood, low water). Ensure the results formalization and banking. The realisation of this practice guide is grounded on the experience of the governmental teams & their partners (or fellows), following existing approaches (Doppler group especially). The guide is designated to validate compliance measures and identify outliers : Hardware, methodological, environmental, or human. Inter-laboratory comparison provides the means to verify the compliance of the instruments (devices + methods + operators) and provides methods to determine an experimental uncertainty of the tested measurement method which is valid only for the site and the measurement conditions but does not address the calibration or periodic monitoring of the few materials. After some conceptual definitions, the guide describes the different stages of an inter-comparison campaign: the campaing creation: targets, participants ( instruments type and number) and site preparation of test protocols and schedule; the campaign set-up (organization): invitation and pre-information of the participants, logistics, field preparation; the campaign conduct: participants reception and information, sequences of tests, results analysis and communication, balance sheet; post-campaign work: further analysis, dissemination and periodic verification of the instruments. This guide is associated with measurement instruments forms, reminding their limits and conditions for use, land forms, used to record all the necessary information during the inter-comparison campaign (site description and measurement conditions, equipment and its settings, and the set of measurements or intermediate calculations to the final results) as well as a calculation tool and banking measures and results.

  7. Structural and functional alterations in the prefrontal cortex after post-weaning social isolation: relationship with species-typical and deviant aggression.

    PubMed

    Biro, Laszlo; Toth, Mate; Sipos, Eszter; Bruzsik, Biborka; Tulogdi, Aron; Bendahan, Samuel; Sandi, Carmen; Haller, Jozsef

    2017-05-01

    Although the inhibitory control of aggression by the prefrontal cortex (PFC) is the cornerstone of current theories of aggression control, a number of human and laboratory studies showed that the execution of aggression increases PFC activity; moreover, enhanced activation was observed in aggression-related psychopathologies and laboratory models of abnormal aggression. Here, we investigated these apparently contradictory findings in the post-weaning social isolation paradigm (PWSI), an established laboratory model of abnormal aggression. When studied in the resident-intruder test as adults, rats submitted to PWSI showed increased attack counts, increased share of bites directed towards vulnerable body parts of opponents (head, throat, and belly) and reduced social signaling of attacks. These deviations from species-typical behavioral characteristics were associated with a specific reduction in the thickness of the right medial PFC (mPFC), a bilateral decrease in dendritic and glial density, and reduced vascularization on the right-hand side of the mPFC. Thus, the early stressor interfered with mPFC development. Despite these structural deficits, aggressive encounters enhanced the activation of the mPFC in PWSI rats as compared to controls. A voxel-like functional analysis revealed that overactivation was restricted to a circumscribed sub-region, which contributed to the activation of hypothalamic centers involved in the initiation of biting attacks as shown by structural equation modeling. These findings demonstrate that structural alterations and functional hyperactivity can coexist in the mPFC of rats exposed to early stressors, and suggest that the role of the mPFC in aggression control is more complex than suggested by the inhibitory control theory.

  8. The use of pre-test and post-test probability values as criteria before selecting patients to undergo coronary angiography in patients who have ischemic findings on myocardial perfusion scintigraphy.

    PubMed

    Karahan Şen, Nazlı Pınar; Bekiş, Recep; Ceylan, Ali; Derebek, Erkan

    2016-07-01

    Myocardial perfusion scintigraphy (MPS) is a diagnostic test which is frequently used in the diagnosis of coronary heart disease (CHD). MPS is generally interpreted as ischemia present or absent; however, it has a power in predicting the disease, similar to other diagnostic tests. In this study, we aimed to assist in directing the high-risk patients to undergo coronary angiography (CA) primarily by evaluating patients without prior CHD history with pre-test and post-test probabilities. The study was designed as a retrospective study. Between January 2008 and July 2011, 139 patients with positive MPS results and followed by CA recently (<6 months) were evaluated from patient files. Patients' pre-test probabilities based on the Diamond and Forrester method and the likelihood ratios that were obtained from the literature were used to calculate the patients' post exercise and post-MPS probabilities. Patients were evaluated in risk groups as low, intermediate, and high, and an ROC curve analysis was performed for the post-MPS probabilities. Coronary artery stenosis (CAS) was determined in 59 patients (42.4%). A significant difference was determined between the risk groups according to CAS, both for the pre-test and post-test probabilities (p<0.001, p=0.024). The ROC analysis provided a cut-off value of 80.4% for post- MPS probability in predicting CAS with 67.9% sensitivity and 77.8% specificity. When the post-MPS probability is ≥80% in patients who have reversible perfusion defects on MPS, we suggest interpreting the MPS as "high probability positive" to improve the selection of true-positive patients to undergo CA, and these patients should be primarily recommended CA.

  9. The use of pre-test and post-test probability values as criteria before selecting patients to undergo coronary angiography in patients who have ischemic findings on myocardial perfusion scintigraphy

    PubMed Central

    Şen, Nazlı Pınar Karahan; Bekiş, Recep; Ceylan, Ali; Derebek, Erkan

    2016-01-01

    Objective: Myocardial perfusion scintigraphy (MPS) is a diagnostic test which is frequently used in the diagnosis of coronary heart disease (CHD). MPS is generally interpreted as ischemia present or absent; however, it has a power in predicting the disease, similar to other diagnostic tests. In this study, we aimed to assist in directing the high-risk patients to undergo coronary angiography (CA) primarily by evaluating patients without prior CHD history with pre-test and post-test probabilities. Methods: The study was designed as a retrospective study. Between January 2008 and July 2011, 139 patients with positive MPS results and followed by CA recently (<6 months) were evaluated from patient files. Patients’ pre-test probabilities based on the Diamond and Forrester method and the likelihood ratios that were obtained from the literature were used to calculate the patients’ post-exercise and post-MPS probabilities. Patients were evaluated in risk groups as low, intermediate, and high, and an ROC curve analysis was performed for the post-MPS probabilities. Results: Coronary artery stenosis (CAS) was determined in 59 patients (42.4%). A significant difference was determined between the risk groups according to CAS, both for the pre-test and post-test probabilities (p<0.001, p=0.024). The ROC analysis provided a cut-off value of 80.4% for post-MPS probability in predicting CAS with 67.9% sensitivity and 77.8% specificity. Conclusion: When the post-MPS probability is ≥80% in patients who have reversible perfusion defects on MPS, we suggest interpreting the MPS as “high probability positive” to improve the selection of true-positive patients to undergo CA, and these patients should be primarily recommended CA. PMID:27004704

  10. Reliability on intra-laboratory and inter-laboratory data of hair mineral analysis comparing with blood analysis.

    PubMed

    Namkoong, Sun; Hong, Seung Phil; Kim, Myung Hwa; Park, Byung Cheol

    2013-02-01

    Nowadays, although its clinical value remains controversial institutions utilize hair mineral analysis. Arguments about the reliability of hair mineral analysis persist, and there have been evaluations of commercial laboratories performing hair mineral analysis. The objective of this study was to assess the reliability of intra-laboratory and inter-laboratory data at three commercial laboratories conducting hair mineral analysis, compared to serum mineral analysis. Two divided hair samples taken from near the scalp were submitted for analysis at the same time, to all laboratories, from one healthy volunteer. Each laboratory sent a report consisting of quantitative results and their interpretation of health implications. Differences among intra-laboratory and interlaboratory data were analyzed using SPSS version 12.0 (SPSS Inc., USA). All the laboratories used identical methods for quantitative analysis, and they generated consistent numerical results according to Friedman analysis of variance. However, the normal reference ranges of each laboratory varied. As such, each laboratory interpreted the patient's health differently. On intra-laboratory data, Wilcoxon analysis suggested they generated relatively coherent data, but laboratory B could not in one element, so its reliability was doubtful. In comparison with the blood test, laboratory C generated identical results, but not laboratory A and B. Hair mineral analysis has its limitations, considering the reliability of inter and intra laboratory analysis comparing with blood analysis. As such, clinicians should be cautious when applying hair mineral analysis as an ancillary tool. Each laboratory included in this study requires continuous refinement from now on for inducing standardized normal reference levels.

  11. Microgravity effects on standardized cognitive performance measures

    NASA Technical Reports Server (NTRS)

    Schiflett, Samuel G.

    1992-01-01

    The purpose of this experiment, selected to fly on the International Microgravity Laboratory (IML-2) Spacelab mission, is to determine the effects of microgravity upon the cognitive skills which are critical to successful performance of many tasks on board the Space Shuttle. Six tests from the Unified Tri-service Cognitive Performance Assessment Battery (UTC-PAB) will be administered to the Mission Specialists to fulfill the goals of this experiment. These tests are based upon current theoretical models of human performance and the hypothesized effects of microgravity. The principle objective is the identification of the effects of microgravity upon specific information processing skills affecting performance from those of fatigue and shifts in work/rest cycles. Multiple measures of both short and long term fatigue will be obtained and used as a major independent variable for the analysis of these performance data. Scientific supporting studies will determine optimum practice and performance testing schedules for the astronauts. The same tests will be used post-flight to collect data on the recovery of any cognitive performance impairment compared with pre-flight, baseline levels.

  12. Remote Laboratory and Animal Behaviour: An Interactive Open Field System

    ERIC Educational Resources Information Center

    Fiore, Lorenzo; Ratti, Giovannino

    2007-01-01

    Remote laboratories can provide distant learners with practical acquisitions which would otherwise remain precluded. Our proposal here is a remote laboratory on a behavioural test (open field test), with the aim of introducing learners to the observation and analysis of stereotyped behaviour in animals. A real-time video of a mouse in an…

  13. Interpretation of diagnostic data: 5. How to do it with simple maths.

    PubMed

    1983-11-01

    The use of simple maths with the likelihood ratio strategy fits in nicely with our clinical views. By making the most out of the entire range of diagnostic test results (i.e., several levels, each with its own likelihood ratio, rather than a single cut-off point and a single ratio) and by permitting us to keep track of the likelihood that a patient has the target disorder at each point along the diagnostic sequence, this strategy allows us to place patients at an extremely high or an extremely low likelihood of disease. Thus, the numbers of patients with ultimately false-positive results (who suffer the slings of labelling and the arrows of needless therapy) and of those with ultimately false-negative results (who therefore miss their chance for diagnosis and, possibly, efficacious therapy) will be dramatically reduced. The following guidelines will be useful in interpreting signs, symptoms and laboratory tests with the likelihood ratio strategy: Seek out, and demand from the clinical or laboratory experts who ought to know, the likelihood ratios for key symptoms and signs, and several levels (rather than just the positive and negative results) of diagnostic test results. Identify, when feasible, the logical sequence of diagnostic tests. Estimate the pretest probability of disease for the patient, and, using either the nomogram or the conversion formulas, apply the likelihood ratio that corresponds to the first diagnostic test result. While remembering that the resulting post-test probability or odds from the first test becomes the pretest probability or odds for the next diagnostic test, repeat the process for all the pertinent symptoms, signs and laboratory studies that pertain to the target disorder. However, these combinations may not be independent, and convergent diagnostic tests, if treated as independent, will combine to overestimate the final post-test probability of disease. You are now far more sophisticated in interpreting diagnostic tests than most of your teachers. In the last part of our series we will show you some rather complex strategies that combine diagnosis and therapy, quantify our as yet nonquantified ideas about use, and require the use of at least a hand calculator.

  14. Interpretation of diagnostic data: 5. How to do it with simple maths.

    PubMed Central

    1983-01-01

    The use of simple maths with the likelihood ratio strategy fits in nicely with our clinical views. By making the most out of the entire range of diagnostic test results (i.e., several levels, each with its own likelihood ratio, rather than a single cut-off point and a single ratio) and by permitting us to keep track of the likelihood that a patient has the target disorder at each point along the diagnostic sequence, this strategy allows us to place patients at an extremely high or an extremely low likelihood of disease. Thus, the numbers of patients with ultimately false-positive results (who suffer the slings of labelling and the arrows of needless therapy) and of those with ultimately false-negative results (who therefore miss their chance for diagnosis and, possibly, efficacious therapy) will be dramatically reduced. The following guidelines will be useful in interpreting signs, symptoms and laboratory tests with the likelihood ratio strategy: Seek out, and demand from the clinical or laboratory experts who ought to know, the likelihood ratios for key symptoms and signs, and several levels (rather than just the positive and negative results) of diagnostic test results. Identify, when feasible, the logical sequence of diagnostic tests. Estimate the pretest probability of disease for the patient, and, using either the nomogram or the conversion formulas, apply the likelihood ratio that corresponds to the first diagnostic test result. While remembering that the resulting post-test probability or odds from the first test becomes the pretest probability or odds for the next diagnostic test, repeat the process for all the pertinent symptoms, signs and laboratory studies that pertain to the target disorder. However, these combinations may not be independent, and convergent diagnostic tests, if treated as independent, will combine to overestimate the final post-test probability of disease. You are now far more sophisticated in interpreting diagnostic tests than most of your teachers. In the last part of our series we will show you some rather complex strategies that combine diagnosis and therapy, quantify our as yet nonquantified ideas about use, and require the use of at least a hand calculator. PMID:6671182

  15. NASA Dryden Flight Loads Laboratory

    NASA Technical Reports Server (NTRS)

    Horn, Tom

    2008-01-01

    This viewgraph presentation reviews the work of the Dryden Flight Loads Laboratory. The capabilities and research interests of the lab are: Structural, thermal, & dynamic analysis; Structural, thermal, & dynamic ground-test techniques; Advanced structural instrumentation; and Flight test support.

  16. Study of variables affecting critical value notification in a laboratory catering to tertiary care hospital.

    PubMed

    Agarwal, Rachna; Chhillar, Neelam; Tripathi, Chandra B

    2015-01-01

    During post-analytical phase, critical value notification to responsible caregiver in a timely manner has potential to improve patient safety which requires cooperative efforts between laboratory personnel and caregivers. It is widely accepted by hospital accreditors that ineffective notification can lead to diagnostic errors that potentially harm patients and are preventable. The objective of the study was to assess the variables affecting critical value notification, their role in affecting it's quality and approaches to improve it. In the present study 1,187 critical values were analysed in the Clinical Chemistry Laboratory catering to tertiary care hospital for neuropsychiatric diseases. During 25 months of study period, we evaluated critical value notification with respect to clinical care area, caregiver to whom it was notified and timeliness of notification. During the study period (25 months), the laboratory obtained 1,279 critical values in clinical chemistry. The analytes most commonly notified were sodium and potassium (20.97 & 20.8 % of total critical results). Analysis of critical value notification versus area of care showed that critical value notification was high in ICU and emergency area followed by inpatients and 64.61 % critical values were notified between 30 and 120 min after receiving the samples. It was found that failure to notify the responsible caregiver in timely manner represent an important patient safety issue and may lead to diagnostic errors. The major area of concern are notification of critical value for outpatient samples, incompleteness of test requisition forms regarding illegible writing, lack of information of treating physician and location of test ordering and difficulty in contacting the responsible caregiver.

  17. Influence of Hip Abductor Strength on Functional Outcomes Before and After Total Knee Arthroplasty: Post Hoc Analysis of a Randomized Controlled Trial.

    PubMed

    Loyd, Brian J; Jennings, Jason M; Judd, Dana L; Kim, Raymond H; Wolfe, Pamela; Dennis, Douglas A; Stevens-Lapsley, Jennifer E

    2017-09-01

    Total knee arthroplasty (TKA) is associated with declines in hip abductor (HA) muscle strength; however, a longitudinal analysis demonstrating the influence of TKA on trajectories of HA strength change has not been conducted. The purpose of this study was to quantify changes in HA strength from pre-TKA through 3 months post-TKA and to characterize the relationship between HA strength changes and physical performance. This study is a post hoc analysis of a randomized controlled trial. Data from 162 participants (89 women, mean age = 63 y) were used for analysis. Data were collected by masked assessors preoperatively and at 1 and 3 months following surgery. Outcomes included: Timed "Up and Go" test (TUG), Stair Climbing Test (SCT), Six-Minute Walk Test (6MWT), and walking speed. Paired t tests were used for between- and within-limb comparisons of HA strength. Multivariable regression was used to determine contributions of independent variables, HA and knee extensor strength, to the dependent variables of TUG, SCT, 6MWT, and walking speed at each time point. Hip abductor strength was significantly lower in the surgical limb pre-TKA (mean = 0.015; 95% CI = 0.010-0.020), 1 month post-TKA (0.028; 0.023-0.034), and 3 months post-TKA (0.02; 0.014-0.025) compared with the nonsurgical limb. Hip abductor strength declined from pre-TKA to 1 month post-TKA (18%), but not at the 3-month time point (0%). Hip abductor strength independently contributed to performance-based outcomes pre-TKA; however, this contribution was not observed post-TKA. The post hoc analysis prevents examining all outcomes likely to be influenced by HA strength. Surgical limb HA strength is impaired prior to TKA, and worsens following surgery. Furthermore, HA strength contributes to performance-based outcomes, supporting the hypothesis that HA strength influences functional recovery. © 2017 American Physical Therapy Association

  18. Misleading biochemical laboratory test results

    PubMed Central

    Nanji, Amin A.

    1984-01-01

    This article reviews the general and specific factors that interfere with the performance of common biochemical laboratory tests and the interpretation of their results. The clinical status of the patient, drug interactions, and in-vivo and in-vitro biochemical interactions and changes may alter the results obtained from biochemical analysis of blood constituents. Failure to recognize invalid laboratory test results may lead to injudicious and dangerous management of patients. PMID:6375845

  19. THE PATHOMECHANICAL ETIOLOGY OF POST-TRAUMATIC OSTEOARTHRITIS FOLLOWING INTRAARTICULAR FRACTURES

    PubMed Central

    Anderson, Donald D; Marsh, J Lawrence; Brown, Thomas D

    2011-01-01

    Many intra-articular fracture patients eventually experience significant functional deficits, pain, and stiffness from post-traumatic osteoarthritis (PTOA). Over the last several decades, continued refinement of surgical reconstruction techniques has failed to markedly improve patient outcomes. New treatment paradigms are needed - ideally, bio/pharmaceutical. Progress in that direction has been impeded because the pathomechanical etiol-ogy of PTOA development is poorly understood. In particular, the relative roles and pathomechanisms of acute joint injury (from the initial trauma) versus chronic contact stress elevation (from residual incongruity) are unknown, primarily because there have been no objective methods for reliably quantifying either of these insult entities. Over the past decade, novel enabling technologies have been developed that provide objective biomechanical indices of injury severity and of chronic contact stress challenge to fractured joint surfaces. The severity of the initial joint injury is indexed primarily on the basis of the energy released in fracture, obtained from validated digital image analysis of CT scans. Chronic contact stress elevations are indexed by patient-specific finite element stress analysis, using models derived from post-reduction CT scans. These new measures, conceived in the laboratory, have been taken through the stage of validation, and then have been applied in studies of intra-articular fracture patients, to relate these biomechanical indices of cartilage insult to the incidence and severity of PTOA This body of work has provided a novel framework for developing and testing new approaches to forestall PTOA following intra-articular fractures. PMID:22096414

  20. Combustion of Hazard Division 1.3 M1 Gun Propellant in a Reinforced Concrete Structure

    DTIC Science & Technology

    2015-08-01

    pretest setup and post - test remains. An overall picture of ground zero and the surrounding location was taken for each test . Photographs were taken...how the door was tied in was made based on post - test pictures following rupture of the structure from Tests 2 and 4. The pressure-time histories from...analysis. The Kasun structure was modeled according to the drawings; deviation from drawing design on how the door was tied in was made based on post

  1. Zinc Finger Transcription Factors as Novel Genetic Switches to Modulate Metastatic Progression of Breast Tumors

    DTIC Science & Technology

    2008-05-01

    critical level of significance set up at P < 0.05, and significant differences between groups of treatments were analyzed with post hoc Turkish test ...2008 differences between groups of treatments were analyzed with post hoc Turkish test . As shown in Fig. 2A, particular ATFs synergized with chromatin...using ANOVA test and the post hoc Turkish test ; critical level of significance was set up at P < 0.05. B, real- time expression analysis of maspin mRNA

  2. Space Shuttle Columbia Aging Wiring Failure Analysis

    NASA Technical Reports Server (NTRS)

    McDaniels, Steven J.

    2005-01-01

    A Space Shuttle Columbia main engine controller 14 AWG wire short circuited during the launch of STS-93. Post-flight examination divulged that the wire had electrically arced against the head of a nearby bolt. More extensive inspection revealed additional damage to the subject wire, and to other wires as well from the mid-body of Columbia. The shorted wire was to have been constructed from nickel-plated copper conductors surrounded by the polyimide insulation Kapton, top-coated with an aromatic polyimide resin. The wires were analyzed via scanning electron microscope (SEM), energy dispersive X-Ray spectroscopy (EDX), and electron spectroscopy for chemical analysis (ESCA); differential scanning calorimetry (DSC) and thermal gravimetric analysis (TGA) were performed on the polyimide. Exemplar testing under laboratory conditions was performed to replicate the mechanical damage characteristics evident on the failed wires. The exemplar testing included a step test, where, as the name implies, a person stepped on a simulated wire bundle that rested upon a bolt head. Likewise, a shear test that forced a bolt head and a torque tip against a wire was performed to attempt to damage the insulation and conductor. Additionally, a vibration test was performed to determine if a wire bundle would abrade when vibrated against the head of a bolt. Also, an abrasion test was undertaken to determine if the polyimide of the wire could be damaged by rubbing against convolex helical tubing. Finally, an impact test was performed to ascertain if the use of the tubing would protect the wire from the strike of a foreign object.

  3. Hemodynamic and psychological responses to laboratory stressors in women: Assessing the roles of menstrual cycle phase, premenstrual symptomatology, and sleep characteristics

    PubMed Central

    Lustyk, M. Kathleen B.; Douglas, Haley A.C.; Shilling, Elizabeth A.; Woods, Nancy F.

    2016-01-01

    This study assessed whether premenstrual symptomatology and/or sleep characteristics explain increased luteal phase psychophysiological reactivity to laboratory stressors. We hypothesized that: (1) premenstrual symptoms and sleep characteristics would explain greater luteal versus follicular phase psychophysiological reactivity, (2) symptoms and sleep characteristics would differentially predict psychophysiological reactivity within each cycle phase, and (3) symptoms and sleep characteristics would interact to affect luteal but not follicular reactivity. Freely cycling women (N=87) completed two laboratory sessions, one follicular (cycle days 5–9) and one luteal (days 7–10 post-ovulation). We employed two stressors: one physical (cold pressor task) and the other cognitive in nature (Paced Auditory Serial Addition Task). During testing, electrocardiography monitored heart rate (HR) while a timed and auto-inflatable sphygmomanometer assessed blood pressure (BP). Participants also completed a one-time self-report measure of sleep characteristics and premenstrual symptomatology as well as a measure of state anxiety pre-post stressor. Results revealed greater luteal HR and systolic BP reactivity compared to follicular reactivity (p<0.001 for both analyses), however neither premenstrual symptoms nor sleep characteristics explained this luteal increase. Within cycle analyses revealed that symptoms and sleep characteristics interacted to affect luteal phase state anxiety reactivity (R2=.32, p=.002) with negative affect being associated with more reactivity when sleep hours were low (β=.333, p=.04). Overall, significant relationships existed during the luteal phase only. Findings are discussed in terms of clinical utility and methodological challenges related to performing laboratory stress testing in women. PMID:23092740

  4. Proficiency Testing for Determination of Water Content in Toluene of Chemical Reagents by iteration robust statistic technique

    NASA Astrophysics Data System (ADS)

    Wang, Hao; Wang, Qunwei; He, Ming

    2018-05-01

    In order to investigate and improve the level of detection technology of water content in liquid chemical reagents of domestic laboratories, proficiency testing provider PT0031 (CNAS) has organized proficiency testing program of water content in toluene, 48 laboratories from 18 provinces/cities/municipals took part in the PT. This paper introduces the implementation process of proficiency testing for determination of water content in toluene, including sample preparation, homogeneity and stability test, the results of statistics of iteration robust statistic technique and analysis, summarized and analyzed those of the different test standards which are widely used in the laboratories, put forward the technological suggestions for the improvement of the test quality of water content. Satisfactory results were obtained by 43 laboratories, amounting to 89.6% of the total participating laboratories.

  5. Effect of feedback techniques for lower back pain on gluteus maximus and oblique abdominal muscle activity and angle of pelvic rotation during the clam exercise.

    PubMed

    Koh, Eun-Kyung; Park, Kyue-Nam; Jung, Do-Young

    2016-11-01

    This study was conducted in order to determine the effect of feedback tools on activities of the gluteus maximus (Gmax) and oblique abdominal muscles and the angle of pelvic rotation during clam exercise (CE). Comparative study using repeated measures. University laboratory. Sixteen subjects with lower back pain. Each subject performed the CE without feedback, the CE using a pressure biofeedback unit (CE-PBU), and the CE with palpation and visual feedback (CE-PVF). Electromyographic (EMG) activity and the angles of pelvic rotation were measured using surface EMG and a three-dimensional motion-analysis system, respectively. One-way repeated-measures ANOVA followed by the Bonferroni post hoc test were used to compare the EMG activity in each muscle as well as the angle of pelvic rotation during the CE, CE-PBU, and CE-PVF. The results of post-hoc testing showed a significantly reduced angle of pelvic rotation and significantly more Gmax EMG activity during the CE-PVF compared with during the CE and CE-PBU. These findings suggest that palpation and visual feedback is effective for activating the Gmax and controlling pelvic rotation during the CE in subjects with lower back pain. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Enduring effects of post-weaning rearing condition on depressive- and anxiety-like behaviors and motor activity in male rats.

    PubMed

    Mosaferi, Belal; Babri, Shirin; Ebrahimi, Hadi; Mohaddes, Gisou

    2015-04-01

    Environmental manipulation at early critical periods could have long-lasting effects. In spite of the great interest in the biological effects of the environmental condition so far, its long-lasting effects are less documented. This study looks at the enduring effects of rearing condition on tasks that measure affective responses and exploratory behavior in male Wistar rats. The animals were reared from weaning to adulthood in an enriched environment, standard laboratory condition, or isolated condition. Then, all rats were housed in standard laboratory cages to provide a common environment, and successively exposed to different tests between 0 and 11 weeks post-manipulation. The open field test indicated a more efficient exploratory behavior in the enriched group, and an enhanced spontaneous motor activity in both standard and isolated groups. In addition, rats reared in standard condition showed heightened motor activity in forced swimming test and elevated plus maze. Forced swimming test showed an antidepressive-like effect in the enriched environment group by increased climbing behavior. In respect to the anxiety behavior, environmental enrichment improved threat detection ability. It is concluded that rearing condition from weaning to adulthood has important and long-lasting effects on depressive- and anxiety-like and exploratory behaviors as well as motor activity. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. LabTrove: A Lightweight, Web Based, Laboratory “Blog” as a Route towards a Marked Up Record of Work in a Bioscience Research Laboratory

    PubMed Central

    Milsted, Andrew J.; Hale, Jennifer R.; Frey, Jeremy G.; Neylon, Cameron

    2013-01-01

    Background The electronic laboratory notebook (ELN) has the potential to replace the paper notebook with a marked-up digital record that can be searched and shared. However, it is a challenge to achieve these benefits without losing the usability and flexibility of traditional paper notebooks. We investigate a blog-based platform that addresses the issues associated with the development of a flexible system for recording scientific research. Methodology/Principal Findings We chose a blog-based approach with the journal characteristics of traditional notebooks in mind, recognizing the potential for linking together procedures, materials, samples, observations, data, and analysis reports. We implemented the LabTrove blog system as a server process written in PHP, using a MySQL database to persist posts and other research objects. We incorporated a metadata framework that is both extensible and flexible while promoting consistency and structure where appropriate. Our experience thus far is that LabTrove is capable of providing a successful electronic laboratory recording system. Conclusions/Significance LabTrove implements a one-item one-post system, which enables us to uniquely identify each element of the research record, such as data, samples, and protocols. This unique association between a post and a research element affords advantages for monitoring the use of materials and samples and for inspecting research processes. The combination of the one-item one-post system, consistent metadata, and full-text search provides us with a much more effective record than a paper notebook. The LabTrove approach provides a route towards reconciling the tensions and challenges that lie ahead in working towards the long-term goals for ELNs. LabTrove, an electronic laboratory notebook (ELN) system from the Smart Research Framework, based on a blog-type framework with full access control, facilitates the scientific experimental recording requirements for reproducibility, reuse, repurposing, and redeployment. PMID:23935832

  8. LabTrove: a lightweight, web based, laboratory "blog" as a route towards a marked up record of work in a bioscience research laboratory.

    PubMed

    Milsted, Andrew J; Hale, Jennifer R; Frey, Jeremy G; Neylon, Cameron

    2013-01-01

    The electronic laboratory notebook (ELN) has the potential to replace the paper notebook with a marked-up digital record that can be searched and shared. However, it is a challenge to achieve these benefits without losing the usability and flexibility of traditional paper notebooks. We investigate a blog-based platform that addresses the issues associated with the development of a flexible system for recording scientific research. We chose a blog-based approach with the journal characteristics of traditional notebooks in mind, recognizing the potential for linking together procedures, materials, samples, observations, data, and analysis reports. We implemented the LabTrove blog system as a server process written in PHP, using a MySQL database to persist posts and other research objects. We incorporated a metadata framework that is both extensible and flexible while promoting consistency and structure where appropriate. Our experience thus far is that LabTrove is capable of providing a successful electronic laboratory recording system. LabTrove implements a one-item one-post system, which enables us to uniquely identify each element of the research record, such as data, samples, and protocols. This unique association between a post and a research element affords advantages for monitoring the use of materials and samples and for inspecting research processes. The combination of the one-item one-post system, consistent metadata, and full-text search provides us with a much more effective record than a paper notebook. The LabTrove approach provides a route towards reconciling the tensions and challenges that lie ahead in working towards the long-term goals for ELNs. LabTrove, an electronic laboratory notebook (ELN) system from the Smart Research Framework, based on a blog-type framework with full access control, facilitates the scientific experimental recording requirements for reproducibility, reuse, repurposing, and redeployment.

  9. Effects of acute chemotherapy-induced mucositis on spontaneous behaviour and the grimace scale in laboratory rats.

    PubMed

    Whittaker, A L; Leach, M C; Preston, F L; Lymn, K A; Howarth, G S

    2016-04-01

    Intestinal mucositis is a frequent side-effect of chemotherapy treatment. Many oncological research programs aim to identify novel treatments for this distressing condition, and these programs frequently use rat models. Little is known about the presence and progression of pain in these models and how this can best be treated by analgesic therapy. We used a number of behaviour-based methods of pain assessment to determine which tools were best suited for pain identification. Baseline measures for behavioural assessment, rat grimace score and sociability were determined through analysis of continuously recorded video data and an applied social interaction test (n = 16). Mucositis was then induced by intraperitoneal injection of 5-fluorouracil (150 mg/kg) and further behavioural analyses undertaken. An assessment of enrichment interaction was also made by determining the mass of a plastic chew toy gnawed both pre- and post-chemotherapy injection. Behavioural scoring was performed 1, 6, 12, 24 and 48 h after injection, with facial expression being scored at the 12, 24 and 48 h time-points. Sociability testing was performed once during the post-injection period. No significant differences were found in grimace scores between baseline and later daily measures. Behaviours similar to those previously reported post-laparotomy were observed. Writhing, twitching and back-arching behaviours were most evident in rats affected by mucositis and were increased in frequency (respective P values: 0.002, 0.004 and 0.008) 48 h after chemotherapy injection compared with baseline, implying that pain onset occurred around this time-point. Social investigatory behaviour was also increased (P = 0.002) following disease onset. Each day, rats post-5FU injection gnawed a greater percentage of their Nylabone enrichment by weight than the saline-injected control rats (P = 0.046). These data suggest that, of the tools tested, behavioural assessment scoring may find greatest utility in rodent models of intestinal mucositis and should be investigated further. © The Author(s) 2015.

  10. 42 CFR 414.310 - Determination of reasonable charges for physician services furnished to renal dialysis patients.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... supportive of the facility as a whole and of benefit to patients in general. Examples of administrative... laboratory test results, nurses' notes and any other medical documentation, as a basis for— (i) Adjustment of...) Pre-dialysis and post-dialysis examinations, or examinations that could have been furnished on a pre...

  11. 42 CFR 414.310 - Determination of reasonable charges for physician services furnished to renal dialysis patients.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... are supportive of the facility as a whole and of benefit to patients in general. Examples of... laboratory test results, nurses' notes and any other medical documentation, as a basis for— (i) Adjustment of...) Pre-dialysis and post-dialysis examinations, or examinations that could have been furnished on a pre...

  12. 49 CFR 40.14 - What collection information must employers provide to collectors?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... (the checkmark can pre-printed in the appropriate box on the CCF at Step 1-D). (h) Test reason, as appropriate: Pre-employment; Random; Reasonable Suspicion/Reasonable Cause; Post-Accident; Return-to-Duty; and... or ID number. (c) Laboratory name and address (can be pre-printed on the CCF). (d) Employer name...

  13. 49 CFR 40.14 - What collection information must employers provide to collectors?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (the checkmark can pre-printed in the appropriate box on the CCF at Step 1-D). (h) Test reason, as appropriate: Pre-employment; Random; Reasonable Suspicion/Reasonable Cause; Post-Accident; Return-to-Duty; and... or ID number. (c) Laboratory name and address (can be pre-printed on the CCF). (d) Employer name...

  14. 49 CFR 40.14 - What collection information must employers provide to collectors?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (the checkmark can pre-printed in the appropriate box on the CCF at Step 1-D). (h) Test reason, as appropriate: Pre-employment; Random; Reasonable Suspicion/Reasonable Cause; Post-Accident; Return-to-Duty; and... or ID number. (c) Laboratory name and address (can be pre-printed on the CCF). (d) Employer name...

  15. 49 CFR 40.14 - What collection information must employers provide to collectors?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... (the checkmark can pre-printed in the appropriate box on the CCF at Step 1-D). (h) Test reason, as appropriate: Pre-employment; Random; Reasonable Suspicion/Reasonable Cause; Post-Accident; Return-to-Duty; and... or ID number. (c) Laboratory name and address (can be pre-printed on the CCF). (d) Employer name...

  16. 49 CFR 40.14 - What collection information must employers provide to collectors?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... (the checkmark can pre-printed in the appropriate box on the CCF at Step 1-D). (h) Test reason, as appropriate: Pre-employment; Random; Reasonable Suspicion/Reasonable Cause; Post-Accident; Return-to-Duty; and... or ID number. (c) Laboratory name and address (can be pre-printed on the CCF). (d) Employer name...

  17. Novel Card Games for Learning Radiographic Image Quality and Urologic Imaging in Veterinary Medicine.

    PubMed

    Ober, Christopher P

    Second-year veterinary students are often challenged by concepts in veterinary radiology, including the fundamentals of image quality and generation of differential lists. Four card games were developed to provide veterinary students with a supplemental means of learning about radiographic image quality and differential diagnoses in urogenital imaging. Students played these games and completed assessments of their subject knowledge before and after playing. The hypothesis was that playing each game would improve students' understanding of the topic area. For each game, students who played the game performed better on the post-test than students who did not play that game (all p<.01). For three of the four games, students who played each respective game demonstrated significant improvement in scores between the pre-test and the post-test (p<.002). The majority of students expressed that the games were both helpful and enjoyable. Educationally focused games can help students learn classroom and laboratory material. However, game design is important, as the game using the most passive learning process also demonstrated the weakest results. In addition, based on participants' comments, the games were very useful in improving student engagement in the learning process. Thus, use of games in the classroom and laboratory setting seems to benefit the learning process.

  18. College of American Pathologists Gynecologic Cytopathology Quality Consensus Conference on good laboratory practices in gynecologic cytology: background, rationale, and organization.

    PubMed

    Tworek, Joseph A; Henry, Michael R; Blond, Barbara; Jones, Bruce Allen

    2013-02-01

    Gynecologic cytopathology is a heavily regulated field, with Clinical Laboratory Improvement Amendments of 1988 mandating the collection of many quality metrics. There is a lack of consensus regarding methods to collect, monitor, and benchmark these data and how these data should be used in a quality assurance program. Furthermore, the introduction of human papilloma virus testing and proficiency testing has provided more data to monitor. To determine good laboratory practices in quality assurance of gynecologic cytopathology. Data were collected through a written survey consisting of 98 questions submitted to 1245 Clinical Laboratory Improvement Amendments-licensed or Department of Defense laboratories. There were 541 usable responses. Additional input was sought through a Web posting of results and questions on the College of American Pathologists Web site. Four senior authors who authored the survey and 28 cytopathologists and cytotechnologists were assigned to 5 working groups to analyze data and present statements on good laboratory practices in gynecologic cytopathology at the College of American Pathologists Gynecologic Cytopathology Quality Consensus Conference. Ninety-eight attendees at the College of American Pathologists Gynecologic Cytopathology Quality Consensus Conference discussed and voted on good laboratory practice statements to obtain consensus. This paper describes the rationale, background, process, and strengths and limitations of a series of papers that summarize good laboratory practice statements in quality assurance in gynecologic cytopathology.

  19. Pandemic preparedness in Hawaii: a multicenter verification of real-time RT-PCR for the direct detection of influenza virus types A and B.

    PubMed

    Whelen, A Christian; Bankowski, Matthew J; Furuya, Glenn; Honda, Stacey; Ueki, Robert; Chan, Amelia; Higa, Karen; Kumashiro, Diane; Moore, Nathaniel; Lee, Roland; Koyamatsu, Terrie; Effler, Paul V

    2010-01-01

    We integrated multicenter, real-time (RTi) reverse transcription polymerase chain reaction (RT-PCR) screening into a statewide laboratory algorithm for influenza surveillance and response. Each of three sites developed its own testing strategy and was challenged with one randomized and blinded panel of 50 specimens previously tested for respiratory viruses. Following testing, each participating laboratory reported its results to the Hawaii State Department of Health, State Laboratories Division for evaluation and possible discrepant analysis. Two of three laboratories reported a 100% sensitivity and specificity, resulting in a 100% positive predictive value and a 100% negative predictive value (NPV) for influenza type A. The third laboratory showed a 71% sensitivity for influenza type A (83% NPV) with 100% specificity. All three laboratories were 100% sensitive and specific for the detection of influenza type B. Discrepant analysis indicated that the lack of sensitivity experienced by the third laboratory may have been due to the analyte-specific reagent probe used by that laboratory. Use of a newer version of the product with a secondary panel of 20 specimens resulted in a sensitivity and specificity of 100%. All three laboratories successfully verified their ability to conduct clinical testing for influenza using diverse nucleic acid extraction and RTi RT-PCR platforms. Successful completion of the verification by all collaborating laboratories paved the way for the integration of those facilities into a statewide laboratory algorithm for influenza surveillance and response.

  20. Single Group, Pre- and Post-Test Research Designs: Some Methodological Concerns

    ERIC Educational Resources Information Center

    Marsden, Emma; Torgerson, Carole J.

    2012-01-01

    This article provides two illustrations of some of the factors that can influence findings from pre- and post-test research designs in evaluation studies, including regression to the mean (RTM), maturation, history and test effects. The first illustration involves a re-analysis of data from a study by Marsden (2004), in which pre-test scores are…

  1. Laboratory Diagnostics Market in East Africa: A Survey of Test Types, Test Availability, and Test Prices in Kampala, Uganda.

    PubMed

    Schroeder, Lee F; Elbireer, Ali; Jackson, J Brooks; Amukele, Timothy K

    2015-01-01

    Diagnostic laboratory tests are routinely defined in terms of their sensitivity, specificity, and ease of use. But the actual clinical impact of a diagnostic test also depends on its availability and price. This is especially true in resource-limited settings such as sub-Saharan Africa. We present a first-of-its-kind report of diagnostic test types, availability, and prices in Kampala, Uganda. Test types (identity) and availability were based on menus and volumes obtained from clinical laboratories in late 2011 in Kampala using a standard questionnaire. As a measure of test availability, we used the Availability Index (AI). AI is the combined daily testing volumes of laboratories offering a given test, divided by the combined daily testing volumes of all laboratories in Kampala. Test prices were based on a sampling of prices collected in person and via telephone surveys in 2015. Test volumes and menus were obtained for 95% (907/954) of laboratories in Kampala city. These 907 laboratories offered 100 different test types. The ten most commonly offered tests in decreasing order were Malaria, HCG, HIV serology, Syphilis, Typhoid, Urinalysis, Brucellosis, Stool Analysis, Glucose, and ABO/Rh. In terms of AI, the 100 tests clustered into three groups: high (12 tests), moderate (33 tests), and minimal (55 tests) availability. 50% and 36% of overall availability was provided through private and public laboratories, respectively. Point-of-care laboratories contributed 35% to the AI of high availability tests, but only 6% to the AI of the other tests. The mean price of the most commonly offered test types was $2.62 (range $1.83-$3.46). One hundred different laboratory test types were in use in Kampala in late 2011. Both public and private laboratories were critical to test availability. The tests offered in point-of-care laboratories tended to be the most available tests. Prices of the most common tests ranged from $1.83-$3.46.

  2. Analysis of laboratory testing results collected in an enhanced chlamydia surveillance system in Australia, 2008-2010.

    PubMed

    Dimech, Wayne; Lim, Megan S C; Van Gemert, Caroline; Guy, Rebecca; Boyle, Douglas; Donovan, Basil; Hellard, Margaret

    2014-06-12

    Chlamydial infection is the most common notifiable disease in Australia, Europe and the US. Australian notifications of chlamydia rose four-fold from 20,274 cases in 2002 to 80,846 cases in 2011; the majority of cases were among young people aged less than 29 years. Along with test positivity rates, an understanding of the number of tests performed and the demographics of individuals being tested are key epidemiological indicators. The ACCESS Laboratory Network was established in 2008 to address this issue. The ACCESS Laboratory Network collected chlamydia testing data from 15 laboratories around Australia over a three-year period using data extraction software. All chlamydia testing data from participating laboratories were extracted from the laboratory information system; patient identifiers converted to a unique, non-reversible code and de-identified data sent to a single database. Analysis of data by anatomical site included all specimens, but in age and sex specific analysis, only one testing episode was counted. From 2008 to 2010 a total of 628,295 chlamydia tests were referred to the 15 laboratories. Of the 592,626 individual episodes presenting for testing, 70% were from female and 30% from male patients. In female patients, chlamydia positivity rate was 6.4% overall; the highest rate in 14 year olds (14.3%). In male patients, the chlamydia positivity rate was 9.4% overall; the highest in 19 year olds (16.5%). The most common sample type was urine (57%). In 3.2% of testing episodes, multiple anatomical sites were sampled. Urethral swabs gave the highest positivity rate for all anatomical sites in both female (7.7%) and male patients (14%), followed by urine (7.6% and 9.4%, respectively) and eye (6.3% and 7.9%, respectively). The ACCESS Laboratory Network data are unique in both number and scope and are representative of chlamydia testing in both general practice and high-risk clinics. The findings from these data highlight much lower levels of testing in young people aged 20 years or less; in particular female patients aged less than 16 years, despite being the group with the highest positivity rate. Strategies are needed to increase the uptake of testing in this high-risk group.

  3. Analysis of laboratory testing results collected in an enhanced chlamydia surveillance system in Australia, 2008–2010

    PubMed Central

    2014-01-01

    Background Chlamydial infection is the most common notifiable disease in Australia, Europe and the US. Australian notifications of chlamydia rose four-fold from 20,274 cases in 2002 to 80,846 cases in 2011; the majority of cases were among young people aged less than 29 years. Along with test positivity rates, an understanding of the number of tests performed and the demographics of individuals being tested are key epidemiological indicators. The ACCESS Laboratory Network was established in 2008 to address this issue. Methods The ACCESS Laboratory Network collected chlamydia testing data from 15 laboratories around Australia over a three-year period using data extraction software. All chlamydia testing data from participating laboratories were extracted from the laboratory information system; patient identifiers converted to a unique, non-reversible code and de-identified data sent to a single database. Analysis of data by anatomical site included all specimens, but in age and sex specific analysis, only one testing episode was counted. Results From 2008 to 2010 a total of 628,295 chlamydia tests were referred to the 15 laboratories. Of the 592,626 individual episodes presenting for testing, 70% were from female and 30% from male patients. In female patients, chlamydia positivity rate was 6.4% overall; the highest rate in 14 year olds (14.3%). In male patients, the chlamydia positivity rate was 9.4% overall; the highest in 19 year olds (16.5%). The most common sample type was urine (57%). In 3.2% of testing episodes, multiple anatomical sites were sampled. Urethral swabs gave the highest positivity rate for all anatomical sites in both female (7.7%) and male patients (14%), followed by urine (7.6% and 9.4%, respectively) and eye (6.3% and 7.9%, respectively). Conclusions The ACCESS Laboratory Network data are unique in both number and scope and are representative of chlamydia testing in both general practice and high-risk clinics. The findings from these data highlight much lower levels of testing in young people aged 20 years or less; in particular female patients aged less than 16 years, despite being the group with the highest positivity rate. Strategies are needed to increase the uptake of testing in this high-risk group. PMID:24920016

  4. A novel, colorimetric neutralization assay for measuring antibodies to influenza viruses.

    PubMed

    Lehtoranta, Liisa; Villberg, Anja; Santanen, Riitta; Ziegler, Thedi

    2009-08-01

    A colorimetric cell proliferation assay for measuring neutralizing antibodies to influenza viruses in human sera is described. Following a 90-min incubation, the serum-virus mixture was transferred to Madin-Darby canine kidney cells cultured in 96-well plates. After further incubation for three days, a tetrazolium salt was added to the wells. Cellular mitochondrial dehydrogenases cleave the tetrazolium salt to formazan, and the resulting color change is read by a spectrophotometer. The absorbance values correlate directly to the number of viable cells in the assay well and thus also to the neutralizing activity of influenza-specific antibodies present in the serum. With the few hands-on manipulations required, this assay allows simultaneous testing of a considerable number of sera, offers opportunities for automation, and is suitable for use under biosafety level-3 conditions. The test was used to study the antibody response after the administration of seasonal, inactivated, trivalent influenza vaccine. Antibody titers determined by the neutralization test in pre- and post-vaccination serum pairs were compared with those obtained by the hemagglutination inhibition assay. The neutralization test yielded higher pre- and post-vaccination titers and a larger number of significant increases in post-vaccination antibody titer than the hemagglutination inhibition test. This new test format could serve as a valuable laboratory tool for influenza vaccine studies.

  5. A 5-kW xenon ion thruster lifetest

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J.; Verhey, Timothy R.

    1990-01-01

    The results of the first life test of a high power ring-cusp ion thruster are presented. A 30-cm laboratory model thruster was operated steady-state at a nominal beam power of 5 kW on xenon propellant for approximately 900 hours. This test was conducted to identify life-timing erosion modifications, and to demonstrate operation using simplified power processing. The results from this test are described including the conclusions derived from extensive post-test analyses of the thruster. Modifications to the thruster and ground support equipment, which were incorporated to solve problems identified by the lifetest, are also described.

  6. Statistical Analysis Tools for Learning in Engineering Laboratories.

    ERIC Educational Resources Information Center

    Maher, Carolyn A.

    1990-01-01

    Described are engineering programs that have used automated data acquisition systems to implement data collection and analyze experiments. Applications include a biochemical engineering laboratory, heat transfer performance, engineering materials testing, mechanical system reliability, statistical control laboratory, thermo-fluid laboratory, and a…

  7. Upward Flame Propagation and Wire Insulation Flammability: 2006 Round Robin Data Analysis

    NASA Technical Reports Server (NTRS)

    Hirsch, David B.

    2007-01-01

    This viewgraph document reviews test results from tests of different material used for wire insulation for flame propagation and flammability. The presentation focused on investigating data variability both within and between laboratories; evaluated the between-laboratory consistency through consistency statistic h, which indicates how one laboratory s cell average compares with averages from other labs; evaluated the within-laboratory consistency through the consistency statistic k, which is an indicator of how one laboratory s within-laboratory variability compares with the variability of other labs combined; and extreme results were tested to determine whether they resulted by chance or from nonrandom causes (human error, instrument calibration shift, non-adherence to procedures, etc.)

  8. Bibliographic Post-Processing with the TIS Intelligent Gateway: Analytical and Communication Capabilities.

    ERIC Educational Resources Information Center

    Burton, Hilary D.

    TIS (Technology Information System) is an intelligent gateway system capable of performing quantitative evaluation and analysis of bibliographic citations using a set of Process functions. Originally developed by Lawrence Livermore National Laboratory (LLNL) to analyze information retrieved from three major federal databases, DOE/RECON,…

  9. Post-examination interpretation of objective test data: monitoring and improving the quality of high-stakes examinations--a commentary on two AMEE Guides.

    PubMed

    Tavakol, Mohsen; Dennick, Reg

    2012-01-01

    As great emphasis is rightly placed upon the importance of assessment to judge the quality of our future healthcare professionals, it is appropriate not only to choose the most appropriate assessment method, but to continually monitor the quality of the tests themselves, in a hope that we may continually improve the process. This article stresses the importance of quality control mechanisms in the exam cycle and briefly outlines some of the key psychometric concepts including reliability measures, factor analysis, generalisability theory and item response theory. The importance of such analyses for the standard setting procedures is emphasised. This article also accompanies two new AMEE Guides in Medical Education (Tavakol M, Dennick R. Post-examination Analysis of Objective Tests: AMEE Guide No. 54 and Tavakol M, Dennick R. 2012. Post examination analysis of objective test data: Monitoring and improving the quality of high stakes examinations: AMEE Guide No. 66) which provide the reader with practical examples of analysis and interpretation, in order to help develop valid and reliable tests.

  10. An overview of clinical studies on fiber post systems.

    PubMed

    Dikbas, Idil; Tanalp, Jale

    2013-01-01

    Intraradicular posts are useful adjuncts in the restoration of endodontically treated teeth. These systems have undergone a significant evolution in recent years, and fiber-reinforced systems have started to be incorporated into routine clinical care more frequently. Despite the high number of laboratory studies pertaining to the characteristics of fiber posts, clinical studies evaluating their general success rates are rather limited. Since clinical investigations are reliable means to achieve information about the general behavior pattern of materials or techniques, assessment of this data will be beneficial to have a better understanding of fiber-reinforced intraradicular post systems. The purpose of this paper was to make a summary of clinical studies regarding various fiber posts. A PubMed search was conducted and articles dating back to 1990 were retrieved. The paper provides an overview of clinical studies on fiber posts specifically in the last decade as well as commentary analysis.

  11. An Overview of Clinical Studies on Fiber Post Systems

    PubMed Central

    Dikbas, Idil; Tanalp, Jale

    2013-01-01

    Intraradicular posts are useful adjuncts in the restoration of endodontically treated teeth. These systems have undergone a significant evolution in recent years, and fiber-reinforced systems have started to be incorporated into routine clinical care more frequently. Despite the high number of laboratory studies pertaining to the characteristics of fiber posts, clinical studies evaluating their general success rates are rather limited. Since clinical investigations are reliable means to achieve information about the general behavior pattern of materials or techniques, assessment of this data will be beneficial to have a better understanding of fiber-reinforced intraradicular post systems. The purpose of this paper was to make a summary of clinical studies regarding various fiber posts. A PubMed search was conducted and articles dating back to 1990 were retrieved. The paper provides an overview of clinical studies on fiber posts specifically in the last decade as well as commentary analysis. PMID:24250255

  12. Integrated Data Collection Analysis (IDCA) Program - Final Review September 12, 2012 at DHS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandstrom, Mary M.; Brown, Geoffrey W.; Warner, Kirstin F.

    The Integrated Data Collection Analysis (IDCA) program conducted a final program review at the Department of Homeland Security on September 12, 2012. The review was focused on the results of the program over the complete performance period. A summary presentation delineating the accomplished tasks started the meeting, followed by technical presentations on various issues that arose during the performance period. The presentations were completed with a statistical evaluation of the testing results from all the participants in the IDCA Proficiency Test study. The meeting closed with a discussion of potential sources of funding for continuing work to resolve some ofmore » these technical issues. This effort, funded by the Department of Homeland Security (DHS), put the issues of safe handling of these materials in perspective with standard military explosives. The study added Small-Scale Safety and Thermal (SSST) testing results for a broad suite of different HMEs to the literature, and suggested new guidelines and methods to develop safe handling practices for HMEs. Each participating testing laboratory used identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results were compared among the laboratories and then compared to historical data from various sources. The testing performers involved were Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Naval Surface Warfare Center, Indian Head Division (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory, Tyndall AFB (AFRL/RXQL). These tests were conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.« less

  13. Adhesive capability of total-etch, self-etch, and self-adhesive systems for fiber post cementation

    NASA Astrophysics Data System (ADS)

    Theodor, Y.; Koesmaningati, H.; Gita, F.

    2017-08-01

    The aim of this study was to analyze whether self-etch and self-adhesive systems are comparable to the total-etch system for fiber post cementation. This experimental laboratory study, which was approved by an ethics committee, was performed using 27 mandibular premolar teeth randomly divided into three groups. Fiber post cementation was done using three different adhesive systems. Specimens were prepared with a thickness of 5 mm, which was measured from the cervical to medial areas of the root, and stored for 24 h in saline solution at room temperature. A push-out test was performed using a universal testing machine (Shimidzu AG-5000E) with a crosshead speed of 0.5 mm/min. The results of one way ANOVA bivariate testing showed that the total-etch and self-etch systems have comparable adhesion capability (p<0.05) and that the self-adhesive system has the lowest adhesion capability (p>0.05). With easier application, the self-etch system has a comparable adhesion capability to the total-etch system.

  14. Inter-laboratory validation of bioaccessibility testing for metals.

    PubMed

    Henderson, Rayetta G; Verougstraete, Violaine; Anderson, Kim; Arbildua, José J; Brock, Thomas O; Brouwers, Tony; Cappellini, Danielle; Delbeke, Katrien; Herting, Gunilla; Hixon, Greg; Odnevall Wallinder, Inger; Rodriguez, Patricio H; Van Assche, Frank; Wilrich, Peter; Oller, Adriana R

    2014-10-01

    Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (sr) and reproducibility (sR) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the sR:sr ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of sr showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Serum neuron-specific enolase levels from the same patients differ between laboratories: assessment of a prospective post-cardiac arrest cohort.

    PubMed

    Mlynash, Michael; Buckwalter, Marion S; Okada, Ami; Caulfield, Anna Finley; Venkatasubramanian, Chitra; Eyngorn, Irina; Verbeek, Marcel M; Wijman, Christine A C

    2013-10-01

    In comatose post-cardiac arrest patients, a serum neuron-specific enolase (NSE) level of >33 μg/L within 72 h was identified as a reliable marker for poor outcome in a large Dutch study (PROPAC), and this level was subsequently adopted in an American Academy of Neurology practice parameter. Later studies reported that NSE >33 μg/L is not a reliable predictor of poor prognosis. To test whether different clinical laboratories contribute to this variability, we compared NSE levels from the laboratory used in the PROPAC study (DLM-Nijmegen) with those of our hospital's laboratory (ARUP) using paired blood samples. We prospectively enrolled cardiac arrest patients who remained comatose after resuscitation. During the first 3 days, paired blood samples for serum NSE were drawn at a median of 10 min apart. After standard preparation for each lab, one sample was sent to ARUP laboratories and the other to DLM-Nijmegen. Fifty-four paired serum samples from 33 patients were included. Although the serum NSE measurements correlated well between laboratories (R = 0.91), the results from ARUP were approximately 30% lower than those from DLM-Nijmegen. Therapeutic hypothermia did not affect this relationship. Two patients had favorable outcomes after hypothermia despite NSE levels measured by DLM-Nijmegen as >33 μg/L. Absolute serum NSE levels of comatose cardiac arrest patients differ between laboratories. Any specific absolute cut-off levels proposed to prognosticate poor outcome should not be used without detailed data on how neurologic outcomes correspond to a particular laboratory's method, and even then only in conjunction with other prognostic variables.

  16. Optimal Sparse Upstream Sensor Placement for Hydrokinetic Turbines

    NASA Astrophysics Data System (ADS)

    Cavagnaro, Robert; Strom, Benjamin; Ross, Hannah; Hill, Craig; Polagye, Brian

    2016-11-01

    Accurate measurement of the flow field incident upon a hydrokinetic turbine is critical for performance evaluation during testing and setting boundary conditions in simulation. Additionally, turbine controllers may leverage real-time flow measurements. Particle image velocimetry (PIV) is capable of rendering a flow field over a wide spatial domain in a controlled, laboratory environment. However, PIV's lack of suitability for natural marine environments, high cost, and intensive post-processing diminish its potential for control applications. Conversely, sensors such as acoustic Doppler velocimeters (ADVs), are designed for field deployment and real-time measurement, but over a small spatial domain. Sparsity-promoting regression analysis such as LASSO is utilized to improve the efficacy of point measurements for real-time applications by determining optimal spatial placement for a small number of ADVs using a training set of PIV velocity fields and turbine data. The study is conducted in a flume (0.8 m2 cross-sectional area, 1 m/s flow) with laboratory-scale axial and cross-flow turbines. Predicted turbine performance utilizing the optimal sparse sensor network and associated regression model is compared to actual performance with corresponding PIV measurements.

  17. Errors in the Extra-Analytical Phases of Clinical Chemistry Laboratory Testing.

    PubMed

    Zemlin, Annalise E

    2018-04-01

    The total testing process consists of various phases from the pre-preanalytical to the post-postanalytical phase, the so-called brain-to-brain loop. With improvements in analytical techniques and efficient quality control programmes, most laboratory errors now occur in the extra-analytical phases. There has been recent interest in these errors with numerous publications highlighting their effect on service delivery, patient care and cost. This interest has led to the formation of various working groups whose mission is to develop standardized quality indicators which can be used to measure the performance of service of these phases. This will eventually lead to the development of external quality assessment schemes to monitor these phases in agreement with ISO15189:2012 recommendations. This review focuses on potential errors in the extra-analytical phases of clinical chemistry laboratory testing, some of the studies performed to assess the severity and impact of these errors and processes that are in place to address these errors. The aim of this review is to highlight the importance of these errors for the requesting clinician.

  18. Can virtual reality exposure therapy gains be generalized to real-life? A meta-analysis of studies applying behavioral assessments.

    PubMed

    Morina, Nexhmedin; Ijntema, Hiske; Meyerbröker, Katharina; Emmelkamp, Paul M G

    2015-11-01

    In virtual reality exposure therapy (VRET), patients are exposed to virtual environments that resemble feared real-life situations. The aim of the current study was to assess the extent to which VRET gains can be observed in real-life situations. We conducted a meta-analysis of clinical trials applying VRET to specific phobias and measuring treatment outcome by means of behavioral laboratory tests or recordings of behavioral activities in real-life. Data sources were searches of databases (Medline, PsycInfo, and Cochrane). We included in total 14 clinical trials on specific phobias. Results revealed that patients undergoing VRET did significantly better on behavioral assessments following treatment than before treatment, with an aggregated uncontrolled effect size of g = 1.23. Furthermore, patients undergoing VRET performed better on behavioral assessments at post-treatment than patients on wait-list (g = 1.41). Additionally, results of behavioral assessment at post-treatment and at follow-up revealed no significant differences between VRET and exposure in vivo (g = -0.09 and 0.53, respectively). Finally, behavioral measurement effect sizes were similar to those calculated from self-report measures. The findings demonstrate that VRET can produce significant behavior change in real-life situations and support its application in treating specific phobias. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Analysis of multiple instructional techniques on the understanding and retention of select mechanical topics

    NASA Astrophysics Data System (ADS)

    Fetsco, Sara Elizabeth

    There are several topics that introductory physics students typically have difficulty understanding. The purpose of this thesis is to investigate if multiple instructional techniques will help students to better understand and retain the material. The three units analyzed in this study are graphing motion, projectile motion, and conservation of momentum. For each unit students were taught using new or altered instructional methods including online laboratory simulations, inquiry labs, and interactive demonstrations. Additionally, traditional instructional methods such as lecture and problem sets were retained. Effectiveness was measured through pre- and post-tests and student opinion surveys. Results suggest that incorporating multiple instructional techniques into teaching will improve student understanding and retention. Students stated that they learned well from all of the instructional methods used except the online simulations.

  20. Lost in Transition: HIV Prevalence and Correlates of Infection among Young People Living in Post-Emergency Phase Transit Camps in Gulu District, Northern Uganda

    PubMed Central

    Patel, Sheetal; Schechter, Martin T.; Sewankambo, Nelson K.; Atim, Stella; Kiwanuka, Noah; Spittal, Patricia M.

    2014-01-01

    Objective Little is known about HIV infection and the related vulnerabilities of young people living in resource-scarce, post-emergency transit camps that are now home to thousands of Internally Displaced Persons (IDPs) following two decades of war in northern Uganda. The objective of this analysis was to assess the prevalence and correlates of HIV infection among young people living in post-conflict transition in Gulu District, northern Uganda. Methods In 2010, a cross-sectional demographic and behavioural survey was conducted in two of Gulu District’s sub-counties with 384 purposively selected transit camp residents aged 15 to 29 years. Biological specimens were collected for rapid HIV testing in the field and confirmatory laboratory testing. Multivariable logistic regression identified independent determinants of HIV infection. Results HIV prevalence was alarmingly high at 12.8% (95% CI: 9.6%, 16.5%). The strongest determinant of HIV infection among young people was a non-consensual sexual debut (adjusted odds ratio [AOR], 9.88; 95% CI: 1.70–18.06). Residing in Awach sub-county (AOR, 2.93; 95% CI: 1.28–6.68), experiencing STI symptoms in the previous 12 months (AOR, 2.36; 95% CI: 1.43–6.17), and practicing dry sex (AOR, 2.31; 95% CI: 1.04–5.13) were other key determinants of HIV infection. Conclusions Study findings contribute to filling an important gap in epidemiological evidence and are useful for planning public health interventions in northern Uganda that effectively target young people in post-conflict transition and support them in the resettlement process. Findings serve to recommend reaching beyond traditional prevention programming in a way more effectively beneficial to young people in post-conflict settings by developing population-specific responses sensitive to local contexts and sufficient to address the underlying causes of the complex risk factors influencing the spread of HIV. PMID:24587034

  1. External Quality Assessment beyond the analytical phase: an Australian perspective.

    PubMed

    Badrick, Tony; Gay, Stephanie; McCaughey, Euan J; Georgiou, Andrew

    2017-02-15

    External Quality Assessment (EQA) is the verification, on a recurring basis, that laboratory results conform to expectations for the quality required for patient care. It is now widely recognised that both the pre- and post-laboratory phase of testing, termed the diagnostic phases, are a significant source of laboratory errors. These errors have a direct impact on both the effectiveness of the laboratory and patient safety. Despite this, Australian laboratories tend to be focussed on very narrow concepts of EQA, primarily surrounding test accuracy, with little in the way of EQA programs for the diagnostic phases. There is a wide range of possibilities for the development of EQA for the diagnostic phases in Australia, such as the utilisation of scenarios and health informatics. Such programs can also be supported through advances in health information and communications technology, including electronic test ordering and clinical decision support systems. While the development of such programs will require consultation and support from the referring doctors, and their format will need careful construction to ensure that the data collected is de-identified and provides education as well as useful and informative data, we believe that there is high value in the development of such programs. Therefore, it is our opinion that all pathology laboratories should strive to be involved in an EQA program in the diagnostic phases to both monitor the diagnostic process and to identify, learn from and reduce errors and near misses in these phases in a timely fashion.

  2. External Quality Assessment beyond the analytical phase: an Australian perspective

    PubMed Central

    Gay, Stephanie; McCaughey, Euan J.; Georgiou, Andrew

    2017-01-01

    External Quality Assessment (EQA) is the verification, on a recurring basis, that laboratory results conform to expectations for the quality required for patient care. It is now widely recognised that both the pre- and post-laboratory phase of testing, termed the diagnostic phases, are a significant source of laboratory errors. These errors have a direct impact on both the effectiveness of the laboratory and patient safety. Despite this, Australian laboratories tend to be focussed on very narrow concepts of EQA, primarily surrounding test accuracy, with little in the way of EQA programs for the diagnostic phases. There is a wide range of possibilities for the development of EQA for the diagnostic phases in Australia, such as the utilisation of scenarios and health informatics. Such programs can also be supported through advances in health information and communications technology, including electronic test ordering and clinical decision support systems. While the development of such programs will require consultation and support from the referring doctors, and their format will need careful construction to ensure that the data collected is de-identified and provides education as well as useful and informative data, we believe that there is high value in the development of such programs. Therefore, it is our opinion that all pathology laboratories should strive to be involved in an EQA program in the diagnostic phases to both monitor the diagnostic process and to identify, learn from and reduce errors and near misses in these phases in a timely fashion. PMID:28392728

  3. Quantification and aging of the post-blast residue of TNT landmines.

    PubMed

    Oxley, Jimmie C; Smith, James L; Resende, Elmo; Pearce, Evan

    2003-07-01

    Post-blast residues are potential interferents to chemical detection of landmines. To assess the potential problem related to 2,4,6-trinitrotoluene (TNT), its post-blast residue was identified and quantified. In the first part of this study laboratory-scale samples of TNT (2 g) were detonated in a small-scale explosivity device (SSED) to evaluate the explosive power and collect post-blast residue for chemical analysis. Initiator size was large relative to the TNT charge; thus, issues arose regarding choice of initiator, residue from the initiator, and afterburning of TNT. The second part of this study detonated 75 to 150 g of military-grade TNT (typical of antipersonnel mines) in 55-gal barrels containing various witness materials (metal plates, sand, barrel walls, the atmosphere). The witness materials were analyzed for explosive residue. In a third set of tests, 75-g samples of TNT were detonated over soil (from Fort Leonard Wood or Sandia National Laboratory) in an indoor firing chamber (100 by 4.6 by 2.7 m high). Targeted in these studies were TNT and four explosive-related compounds (ERC): 2,4-dinitrotoluene (DNT), 1,3-dinitrobenzene (DNB), 2- and 4-aminodinitrotoluene (2-ADNT and 4-ADNT). The latter two are microbial degradation products of TNT. Post-blast residue was allowed to age in the soils as a function of moisture contents (5 and 10%) in order to quantify the rate of degradation of the principal residues (TNT, DNT, and DNB) and formation of the TNT microbial degradation products (2-ADNT and 4-ADNT). The major distinction between landmine leakage and post-blast residue was not the identity of the species but relative ratios of amounts. In landmine leakage the DNT/TNT ratio was usually greater than 1. In post-blast residue it was on the order of 1 to 1/100th of a percent, and the total amount of pre-blast residue (landmine leakage) was a factor of 1/100 to 1/1000 less than post-blast. In addition, landmine leakage resulted in low DNT/ADNT ratios, usually less than 1, whereas pre-blast residues started with ratios above 20. Because with time DNT decreased and ADNT increased, over a month the ratio decreased by a factor of 2. The rate of TNT degradation in soil observed in this study was much slower than that reported when initial concentrations of TNT were lower. Degradation rates yielded half-lives of 40 and 100 days for 2,4-DNT and TNT, respectively.

  4. Assessing student understanding of measurement and uncertainty

    NASA Astrophysics Data System (ADS)

    Jirungnimitsakul, S.; Wattanakasiwich, P.

    2017-09-01

    The objectives of this study were to develop and assess student understanding of measurement and uncertainty. A test has been adapted and translated from the Laboratory Data Analysis Instrument (LDAI) test, consists of 25 questions focused on three topics including measures of central tendency, experimental errors and uncertainties, and fitting regression lines. The test was evaluated its content validity by three physics experts in teaching physics laboratory. In the pilot study, Thai LDAI was administered to 93 freshmen enrolled in a fundamental physics laboratory course. The final draft of the test was administered to three groups—45 freshmen taking fundamental physics laboratory, 16 sophomores taking intermediated physics laboratory and 21 juniors taking advanced physics laboratory at Chiang Mai University. As results, we found that the freshmen had difficulties in experimental errors and uncertainties. Most students had problems with fitting regression lines. These results will be used to improve teaching and learning physics laboratory for physics students in the department.

  5. Squad Modeling and Simulation for Analysis of Materiel and Personnel Solutions

    DTIC Science & Technology

    2014-06-01

    Laboratory MORSS Presentations • Virtual Employment Test Bed: Operational Research and Systems Analysis to Test Armaments Designs Early in the...Elizabeth Mezzacappa, PhD Target Behavioral Response Laboratory Presented to the 82nd Military Operations Research Society Symposium June 4-6, 2014...Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware that notwithstanding

  6. Technical Capabilities of the National Vehicle and Fuel Emissions Laboratory (NVFEL)

    EPA Pesticide Factsheets

    National Vehicle and Fuel Emissions Laboratory (NVFEL) is a state-of-the-art test facility that conducts a wide range of emissions testing and analysis for EPA’s motor vehicle, heavy-duty engine, and nonroad engine programs.

  7. 7 CFR 98.100 - General.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS MEALS, READY-TO-EAT (MRE's), MEATS, AND MEAT PRODUCTS USDA Certification of Laboratories for the Testing of... specified in this subpart shall receive an AMS Science and Technology certificate to approve its analysis...

  8. 7 CFR 98.100 - General.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS MEALS, READY-TO-EAT (MRE's), MEATS, AND MEAT PRODUCTS USDA Certification of Laboratories for the Testing of... specified in this subpart shall receive an AMS Science and Technology certificate to approve its analysis...

  9. 7 CFR 98.100 - General.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS MEALS, READY-TO-EAT (MREs), MEATS, AND MEAT PRODUCTS USDA Certification of Laboratories for the Testing of... specified in this subpart shall receive an AMS Science and Technology certificate to approve its analysis...

  10. 7 CFR 98.100 - General.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS MEALS, READY-TO-EAT (MRE's), MEATS, AND MEAT PRODUCTS USDA Certification of Laboratories for the Testing of... specified in this subpart shall receive an AMS Science and Technology certificate to approve its analysis...

  11. Pre/Post Data Analysis - Simple or Is It?

    NASA Technical Reports Server (NTRS)

    Feiveson, Al; Fiedler, James; Ploutz-Snyder, Robert

    2011-01-01

    This slide presentation reviews some of the problems of data analysis in analyzing pre and post data. Using as an example, ankle extensor strength (AES) experiments, to measure bone density loss during bed rest, the presentation discusses several questions: (1) How should we describe change? (2) Common analysis methods for comparing post to pre results. (3) What do we mean by "% change"? and (4) What are we testing when we compare % changes?

  12. Improvements to constitutive material model for fabrics

    NASA Astrophysics Data System (ADS)

    Morea, Mihai I.

    2011-12-01

    The high strength to weight ratio of woven fabric offers a cost effective solution to be used in a containment system for aircraft propulsion engines. Currently, Kevlar is the only Federal Aviation Administration (FAA) approved fabric for usage in systems intended to mitigate fan blade-out events. This research builds on an earlier constitutive model of Kevlar 49 fabric developed at Arizona State University (ASU) with the addition of new and improved modeling details. Latest stress strain experiments provided new and valuable data used to modify the material model post peak behavior. These changes reveal an overall improvement of the Finite Element (FE) model's ability to predict experimental results. First, the steel projectile is modeled using Johnson-Cook material model and provides a more realistic behavior in the FE ballistic models. This is particularly noticeable when comparing FE models with laboratory tests where large deformations in projectiles are observed. Second, follow-up analysis of the results obtained through the new picture frame tests conducted at ASU provides new values for the shear moduli and corresponding strains. The new approach for analysis of data from picture frame tests combines digital image analysis and a two-level factorial optimization formulation. Finally, an additional improvement in the material model for Kevlar involves checking the convergence at variation of mesh density of fabrics. The study performed and described herein shows the converging trend, therefore validating the FE model.

  13. 18. Photocopy of photograph. VIEW WITHIN POSTMORTEM CELL OF MANIPULATOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Photocopy of photograph. VIEW WITHIN POST-MORTEM CELL OF MANIPULATOR ARMS BEING USED TO MOVE METAL BARS FROM ONE LOCATION TO ANOTHER. Photographer unknown, ca. 1965, original photograph and negative on file at the Remote Sensing Laboratory, Department of Energy, Nevada Operations Office. - Nevada Test Site, Engine Maintenance Assembly & Disassembly Facility, Area 25, Jackass Flats, Mercury, Nye County, NV

  14. Environmental Education & Ecology in a Life Science Course for Preservice K-8 Teachers Using Project Wildlife in Learning Design

    ERIC Educational Resources Information Center

    Nelson, Allan

    2010-01-01

    During laboratory sessions devoted to ecology, 182 preservice K-8 teachers participated in a Project Wildlife in Learning Design (WILD) workshop. Participants rated the workshop highly, indicated they would use more inquiry-based activities, and were more interested in teaching ecology following the workshop. Post-test scores indicated an…

  15. New possibilities to analyse non-standard explosives and post blast residues in forensic practice

    NASA Astrophysics Data System (ADS)

    Kotrlý, Marek; Turková, Ivana

    2005-05-01

    Nonstandard and home-made explosives always pose a considerable threat for security forces in terms of their practically unlimited variability, both in composition and in construction of explosive devises. Electron microscopy - SEM with EDS/WDS is one of the key techniques for an analysis of non-standard explosives and post-blast residues. If the amount of materials allows it, a number of other analytical techniques are utilized, such as XRD that is capable of a direct phase identification of a crystalline substance, namely in mixtures. TLC has constantly proved itself useful for laboratory screening. Furthermore, combinations of FTIR, Raman spectrometry, LC MS, GC MS, XRF, micro XRF and other ones are applied. In the case of identification of post-blast residues, where an investigation is often conducted at the level of separate microscopic particles, the role of SEM is unsubstitutable, whereas the analysis of the organic phase from these often sporadic microparticles has been infeasible until recently. One of the very interesting options appears to be Raman spectrometry technique, which is nowadays obtainable as a supplement to SEM EDX. Newly available is the device that is fully confocal, SEM keeps full functionality and scan range, very high resolution (for green laser resolution 360nm FWHM; 430nm Rayleigh), it is fitted with high quality objective lens, enhances mapping through Raman spectrometry in a volume 250μm x 250μm x 250μm by piezo driven scanner (capacitive feedback linearized) and obtaining a high quality white light image (250μm x 250μm) immediately in the SEM chamber. This technique is currently undergoing intensive testing and it seems that the method could significantly help to address issues with the analysis of organic phases in electron microscopy not only in the case of post-blast residues and explosives.

  16. Monitoring and root cause analysis of clinical biochemistry turn around time at an academic hospital.

    PubMed

    Chauhan, Kiran P; Trivedi, Amit P; Patel, Dharmik; Gami, Bhakti; Haridas, N

    2014-10-01

    Quality can be defined as the ability of a product or service to satisfy the needs and expectations of the customer. Laboratories are more focusing on technical and analytical quality for reliability and accuracy of test results. Patients and clinicians however are interested in rapid, reliable and efficient service from laboratory. Turn around time (TAT), the timeliness with which laboratory personnel deliver test results, is one of the most noticeable signs of laboratory service and is often used as a key performance indicator of laboratory performance. This study is aims to provide clue for laboratory TAT monitoring and root cause analysis. In a 2 year period a total of 75,499 specimens of outdoor patient department were monitor, of this a total of 4,142 specimens exceeded TAT. With consistent efforts to monitor, root cause analysis and corrective measures, we are able to decreased the specimens exceeding TAT from 7-8 to 3.7 %. Though it is difficult task to monitor TAT with the help of laboratory information system, real time documentation and authentic data retrievable, along with identification of causes for delays and its remedial measures, improve laboratory TAT and thus patient satisfaction.

  17. Pre- and Post-Processing Tools to Create and Characterize Particle-Based Composite Model Structures

    DTIC Science & Technology

    2017-11-01

    ARL-TR-8213 ● NOV 2017 US Army Research Laboratory Pre- and Post -Processing Tools to Create and Characterize Particle-Based...ARL-TR-8213 ● NOV 2017 US Army Research Laboratory Pre- and Post -Processing Tools to Create and Characterize Particle-Based Composite...AND SUBTITLE Pre- and Post -Processing Tools to Create and Characterize Particle-Based Composite Model Structures 5a. CONTRACT NUMBER 5b. GRANT

  18. Timing of entry to care by newly diagnosed HIV cases before and after the 2010 New York State HIV testing law.

    PubMed

    Gordon, Daniel E; Bian, Fuqin; Anderson, Bridget J; Smith, Lou C

    2015-01-01

    Prompt entry to care after HIV diagnosis benefits the infected individual and reduces the likelihood of further transmission of the virus. The New York State HIV Testing Law of 2010 requires diagnosing providers to refer persons newly diagnosed with HIV to follow-up medical care. This study used routinely collected HIV-related laboratory data from the New York State HIV surveillance system to assess whether the fraction of newly diagnosed cases entering care within 90 days of diagnosis increased after the implementation of the law. Laboratory data on 23,302 newly diagnosed cases showed that entry to care within 90 days rose steadily from 72.0% in 2007 to 85.4% in 2012. The rise was observed across all race/ethnic groups, ages, transmission risk groups, sexes, and regions of residence. Logistic regression analyses of entry to care pre-law and post-law, controlling for demographic characteristics, transmission risk, and geographic area, indicate that percentage of newly diagnosed cases entering care within 90 days grew more rapidly in the post-law period. This is consistent with a positive effect of the law on entry to care.

  19. Automatic Data Processing Equipment (ADPE) acquisition plan for the medical sciences

    NASA Technical Reports Server (NTRS)

    1979-01-01

    An effective mechanism for meeting the SLSD/MSD data handling/processing requirements for Shuttle is discussed. The ability to meet these requirements depends upon the availability of a general purpose high speed digital computer system. This system is expected to implement those data base management and processing functions required across all SLSD/MSD programs during training, laboratory operations/analysis, simulations, mission operations, and post mission analysis/reporting.

  20. ChemCam for Mars Science Laboratory rover, undergoing pre-flight testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2011-10-20

    Los Alamos National Laboratory and partners developed a laser instrument, ChemCam, that will ride on the elevated mast of the Mars Science Laboratory rover Curiosity. The system allows Curiosity to "zap" rocks from a distance, reading their chemical composition through spectroscopic analysis. In this video, laboratory shaker-table testing of the instrument ensures that all of its components are solidly attached and resistant to damage from the rigors of launch, travel and landing.

  1. ChemCam for Mars Science Laboratory rover, undergoing pre-flight testing

    ScienceCinema

    None

    2018-06-06

    Los Alamos National Laboratory and partners developed a laser instrument, ChemCam, that will ride on the elevated mast of the Mars Science Laboratory rover Curiosity. The system allows Curiosity to "zap" rocks from a distance, reading their chemical composition through spectroscopic analysis. In this video, laboratory shaker-table testing of the instrument ensures that all of its components are solidly attached and resistant to damage from the rigors of launch, travel and landing.

  2. Improvement of analytical capabilities of neutron activation analysis laboratory at the Colombian Geological Survey

    NASA Astrophysics Data System (ADS)

    Parrado, G.; Cañón, Y.; Peña, M.; Sierra, O.; Porras, A.; Alonso, D.; Herrera, D. C.; Orozco, J.

    2016-07-01

    The Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey has developed a technique for multi-elemental analysis of soil and plant matrices, based on Instrumental Neutron Activation Analysis (INAA) using the comparator method. In order to evaluate the analytical capabilities of the technique, the laboratory has been participating in inter-comparison tests organized by Wepal (Wageningen Evaluating Programs for Analytical Laboratories). In this work, the experimental procedure and results for the multi-elemental analysis of four soil and four plant samples during participation in the first round on 2015 of Wepal proficiency test are presented. Only elements with radioactive isotopes with medium and long half-lives have been evaluated, 15 elements for soils (As, Ce, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Th, U and Zn) and 7 elements for plants (Br, Co, Cr, Fe, K, Na and Zn). The performance assessment by Wepal based on Z-score distributions showed that most results obtained |Z-scores| ≤ 3.

  3. Systematic reviews: I. The correlation between laboratory tests on marginal quality and bond strength. II. The correlation between marginal quality and clinical outcome.

    PubMed

    Heintze, Siegward D

    2007-01-01

    An accepted principle in restorative dentistry states that restorations should be placed with the best marginal quality possible to avoid postoperative sensitivity, marginal discoloration, and secondary caries. Different laboratory methods claim to predict the clinical performance of restorative materials, for example, tests of bond strength and microleakage and gap analysis. The purpose of this review was twofold: (1) find studies that correlated the results of bond strength tests with either microleakage or gap analysis for the same materials, and (2) find studies that correlated the results of microleakage and/or gaps with the clinical parameters for the same materials. Furthermore, influencing factors on the results of the laboratory tests were reviewed and assessed. For the first question, searches for studies were conducted in the MEDLINE database and IADR/AADR abtracts online with specific search and inclusion criteria. The outcome for each study was assessed on the basis of the statistical test applied in the study, and finally the number of studies with or without correlation was compiled. For the second question, results of the quantitative marginal analysis of Class V restorations published by the University of Zürich with the same test protocol and prospective clinical trials were searched that investigated the same materials for at least 2 years in Class V cavities. Pearson correlation coefficients were calculated for pooled data of materials and clinical outcome parameters such as retention loss, marginal discoloration, marginal integrity, and secondary caries. For the correlation of dye penetration and clinical outcome, studies on Class V restorations published by the same research institute were searched in MEDLINE that examined the same adhesive systems as the selected clinical trials. For the correlation bond strength/microleakage, 30 studies were included into the review, and for the correlation bond strength/gap analysis 18 studies. For both topics, about 80% of the studies revealed that there was no correlation between the two methods. For the correlation quantitative marginal analysis/clinical outcome, data were compared to the clinical outcome of 11 selected clinical studies. In only 2 out of the 11 studies (18%) did the clinical outcome match the prognosis based on the laboratory tests; the remaining studies did not show any correlation. When pooling data on 20 adhesive systems, no correlation was found between the percentage of continuous margin of restorations placed in extracted premolars and the percentage of teeth that showed no retention loss in clinical studies, no discoloured margins, acceptable margins, or absence of secondary caries. With regard to the correlation of dye penetration and clinical studies, no sufficient number of studies was found that matched the inclusion criteria. However, literature data suggest that there is no correlation between microleakage data as measured in the laboratory and clinical parameters. The results of bond strength tests did not correlate with laboratory tests that evaluated the marginal seal of restorations such as microleakage or gap analysis. The quantitative marginal analysis of Class V fillings in the laboratory was unable to predict the performance of the same materials in vivo. Therefore, microleakage tests or the quantitative marginal analysis should be abandoned and research should focus on laboratory tests that are validated with regard to their ability to satisfactorily predict the clinical performance of restorative materials.

  4. The potential link between sugar-sweetened beverage consumption and post-exercise airway narrowing across puberty: a longitudinal cohort study.

    PubMed

    Emerson, Sam R; Rosenkranz, Sara K; Rosenkranz, Richard R; Kurti, Stephanie P; Harms, Craig A

    2016-09-01

    The prevalence of asthma is rising, presenting serious public health challenges. Recent data suggest that sugar-sweetened beverage (SSB) consumption plays a role in asthma aetiology. The purpose of the present study was to determine whether SSB consumption is linked to post-exercise airway narrowing (predictor of asthma development) across puberty. Participants completed pulmonary function tests, physical activity and dietary habit questionnaires, and an exercise test to exhaustion. Community in Manhattan, Kansas, USA. We recruited ten boys and ten girls from an original cohort of forty participants tested in our laboratory approximately 5 years prior. Participants were aged 9·7 (sd 0·9) years at baseline and 14·7 (sd 0·9) years at follow-up. Pre-puberty, boys consumed 6·8 (sd 4·8) servings/week and girls consumed 6·9 (sd 3·7) servings/week, while post-puberty boys consumed 11·5 (sd 5·3) servings/week and girls consumed 7·7 (sd 4·3) servings/week. Using Pearson correlation, SSB consumption was not significantly related to post-exercise airway narrowing at pre-puberty (r=-0·35, P=0·130). In linear regression analyses, SSB consumption was significantly related to post-exercise airway narrowing post-puberty before (standardized β=-0·60, P=0·005) but not after (standardized β=-0·33, P=0·211) adjustment for confounders. Change in SSB consumption from pre- to post-puberty was significantly associated with post-exercise airway narrowing post-puberty (r=-0·61, P=0·010) and change in post-exercise airway narrowing from pre- to post-puberty (r=-0·45, P=0·048) when assessed via Pearson correlations. These findings suggest a possible link between SSB consumption and asthma development during maturation. Reduced SSB intake may be a possible public health avenue for blunting rising asthma prevalence.

  5. Quality performance of laboratory testing in pharmacies: a collaborative evaluation.

    PubMed

    Zaninotto, Martina; Miolo, Giorgia; Guiotto, Adriano; Marton, Silvia; Plebani, Mario

    2016-11-01

    The quality performance and the comparability between results of pharmacies point-of-care-testing (POCT) and institutional laboratories have been evaluated. Eight pharmacies participated in the project: a capillary specimen collected by the pharmacist and, simultaneously, a lithium-heparin sample drawn by a physician of laboratory medicine for the pharmacy customers (n=106) were analyzed in the pharmacy and in the laboratory, respectively. Glucose, cholesterol, HDL-cholesterol, triglycerides, creatinine, uric acid, aspartate aminotransferase, alanine aminotransferase, were measured using: Reflotron, n=5; Samsung, n=1; Cardiocheck PA, n=1; Cholestech LDX, n=1 and Cobas 8000. The POCT analytical performance only (phase 2) were evaluated testing, in pharmacies and in the laboratory, the lithium heparin samples from a female drawn fasting daily in a week, and a control sample containing high concentrations of glucose, cholesterol and triglycerides. For all parameters, except triglycerides, the slopes showed a satisfactory correlation. For triglycerides, a median value higher in POCT in comparison to the laboratory (1.627 mmol/L vs. 0.950 mmol/L) has been observed. The agreement in the subjects classification, demonstrates that for glucose, 70% of the subjects show concentrations below the POCT recommended level (5.8-6.1 mmol/L), while 56% are according to the laboratory limit (<5.6 mmol/L). Total cholesterol exhibits a similar trend while POCT triglycerides show a greater percentage of increased values (21% vs. 9%). The reduction in triglycerides bias (phase 2) suggests that differences between POCT and central laboratory is attributable to a pre-analytical problem. The results confirm the acceptable analytical performance of POCT pharmacies and specific criticisms in the pre- and post-analytical phases.

  6. Operating environmental laboratories--an overview of analysis equipment procurement and management.

    PubMed

    Pandya, G H; Shinde, V M; Kanade, G S; Kondawar, V K

    2003-10-01

    Management of equipment in an environmental laboratory requires planning involving assessment of the workload on a particular equipment, establishment of criteria and specification for the purchase of equipment, creation of infrastructure for installation and testing of the equipment, optimization of analysis conditions, development of preventive maintenance procedures and establishment of in-house repair facilities. The paper reports the results of such an analysis carried for operating environmental laboratories associated with R& D work, serving as an Govt. laboratory or attached to an Industry for analysing industrial emissions.

  7. Pharmacological and Behavioral Enhancement of Neuroplasticity in the MPTP Lesioned Mouse and Nonhuman Primate

    DTIC Science & Technology

    2007-05-01

    and post - synaptic dopamine biosynthesis, uptake and receptor expression as well as glutamatergic synapses. This hypothesis will be tested through...0.05) compared to mice at 7 days (9.6 ± 3.2%) or 30 days post -MPTP (16.5 ± 7.3%). The tail suspension test showed a significant increase in percent of...were compared using one-way analysis of variance (ANOVA), followed by the Fisher post hoc test for comparison of multiple means for the following

  8. Proceedings of Damping󈨝 Held in West Palm Beach, Florida on 8-10 February 1989. Volume 1. Pages AAB-1 through DCD-11)

    DTIC Science & Technology

    1989-11-01

    environments that the inlet ring encounters and verifying the failure mechanisms through analysis and laboratory test. Due to the inlet ring’s proximity to the...these environments and duty cycles were further explored through finite element analysis and laboratory testing of the baseline structure. An MSC...Layer Damping Applications J. P. Coulter, T. G. Duclos and D. N. Acker CAA Analysis of a Modified Passive Hydraulic Damper with Variable Damping

  9. Cost-effectiveness analysis of universal noninvasive testing for post-treatment confirmation of Helicobacter pylori eradication and the impact of patient adherence.

    PubMed

    Boklage, Susan H; Mangel, Allen W; Ramamohan, Varun; Mladsi, Deirdre; Wang, Tao

    2016-01-01

    The treatment failure rate for Helicobacter pylori eradication therapy is ~20% due to poor patient compliance and increased antibiotic resistance. This analysis assessed the cost-effectiveness of universal post-treatment testing to confirm eradication of H. pylori infection in adults. Decision-analytic models evaluated the cost-effectiveness of universal post-treatment testing (urea breath test [UBT] or monoclonal fecal antigen test [mFAT]) vs no testing (Model 1), and UBT vs mFAT after adjusting for patient adherence to testing (Model 2) in adults who previously received first-line antimicrobial therapy. Patients testing positive received second-line quadruple therapy; no further action was taken for those testing negative or with no testing (Model 1) or for those nonadherent to testing (Model 2). In addition to testing costs, excess lifetime costs and reduced quality-adjusted life-years (QALYs) due to continuing H. pylori infection were considered in the model. Expected total costs per patient were higher for post-treatment testing (UBT: US$325.76; mFAT: US$242.12) vs no testing (US$182.41) in Model 1 and for UBT (US$336.75) vs mFAT (US$326.24) in Model 2. Expected QALYs gained per patient were 0.71 and 0.72 for UBT and mFAT, respectively, vs no testing (Model 1), and the same was 0.37 for UBT vs mFAT (Model 2). The estimated incremental costs per QALY gained for post-treatment testing vs no testing were US$82.90-US$202.45 and, after adjusting for adherence, US$28.13 for UBT vs mFAT. Universal post-treatment testing was found to be cost-effective for confirming eradication of H. pylori infection following first-line therapy. Better adherence to UBT relative to mFAT was the key to its cost-effectiveness.

  10. Gene Polymorphism Studies in a Teaching Laboratory

    NASA Astrophysics Data System (ADS)

    Shultz, Jeffry

    2009-02-01

    I present a laboratory procedure for illustrating transcription, post-transcriptional modification, gene conservation, and comparative genetics for use in undergraduate biology education. Students are individually assigned genes in a targeted biochemical pathway, for which they design and test polymerase chain reaction (PCR) primers. In this example, students used genes annotated for the steroid biosynthesis pathway in soybean. The authoritative Kyoto encyclopedia of genes and genomes (KEGG) interactive database and other online resources were used to design primers based first on soybean expressed sequence tags (ESTs), then on ESTs from an alternate organism if soybean sequence was unavailable. Students designed a total of 50 gene-based primer pairs (37 soybean, 13 alternative) and tested these for polymorphism state and similarity between two soybean and two pea lines. Student assessment was based on acquisition of laboratory skills and successful project completion. This simple procedure illustrates conservation of genes and is not limited to soybean or pea. Cost per student estimates are included, along with a detailed protocol and flow diagram of the procedure.

  11. Dengue-yellow fever sera cross-reactivity; challenges for diagnosis.

    PubMed

    Houghton-Triviño, Natalia; Montaña, Diana; Castellanos, Jaime

    2008-01-01

    The Flavivirus genera share epitopes inducing cross-reactive antibodies leading to great difficulty in differentially diagnosing flaviviral infections. This work was aimed at evaluating the complexity of dengue and yellow fever serological differential diagnosis. Dengue antibody capture ELISA and a yellow fever neutralisation test were carried out on 13 serum samples obtained from yellow fever patients, 20 acute serum samples from dengue patients and 19 voluntary serum samples pre- and post-vaccination with YF vaccine. Dengue ELISA revealed IgM reactivity in 46,2 % of yellow fever patients and 42 % of vaccinees. Sixteen out of 20 dengue patients (80 %) had high YF virus neutralisation titres. Such very high cross-reactivity data challenged differential laboratory diagnosis of dengue and yellow fever in areas where both flaviviruses co-circulate. New laboratory strategies are thus needed for improving the tests and providing a specific laboratory diagnosis. Cross-reactivity between Flaviviruses represents a great difficulty for epidemiological surveillance and preventing dengue, both of which demand urgent attention.

  12. The Impact of Internet Virtual Physics Laboratory Instruction on the Achievement in Physics, Science Process Skills and Computer Attitudes of 10th-Grade Students

    NASA Astrophysics Data System (ADS)

    Yang, Kun-Yuan; Heh, Jia-Sheng

    2007-10-01

    The purpose of this study was to investigate and compare the impact of Internet Virtual Physics Laboratory (IVPL) instruction with traditional laboratory instruction in physics academic achievement, performance of science process skills, and computer attitudes of tenth grade students. One-hundred and fifty students from four classes at one private senior high school in Taoyuan Country, Taiwan, R.O.C. were sampled. All four classes contained 75 students who were equally divided into an experimental group and a control group. The pre-test results indicated that the students' entry-level physics academic achievement, science process skills, and computer attitudes were equal for both groups. On the post-test, the experimental group achieved significantly higher mean scores in physics academic achievement and science process skills. There was no significant difference in computer attitudes between the groups. We concluded that the IVPL had potential to help tenth graders improve their physics academic achievement and science process skills.

  13. The effectiveness of the 1996 Wood Magic Science Fair as an experiential field trip

    NASA Astrophysics Data System (ADS)

    Pearson, Robert Wayne

    In response to the need for evaluating the effectiveness of the 1996 Wood Magic Science Fair (WMSF) at Mississippi State University's Forest and Wildlife Research Center/Forest Products Laboratory, two tests were developed. One test was designed for third-grade students and one for fourth-grade students who would attend the WMSF. Both tests have multiple choice answers and contained thirteen questions each. Five of the questions addressed general issues of the forest products industry that would be mentioned in an opening video but not stressed in the oral presentations of the WMSF. The students would have no active involvement in these presentations. These general issue questions represent passive involvement teaching. The eight remaining questions addressed specific information that would be stressed in the WMSF oral presentations and would allow students to actively participate in the presentations. The participation of the students in these presentations represents participatory teaching. The tests were given to the students (third and fourth grades) both before they attended the fair as a pre-test and after their attendance as a post-test with the only difference being that the multiple choice answers were arranged in a different order. Classroom teachers administered the tests to the students. The test results were evaluated for each class individually. Each question was evaluated and the results recorded in a table. The general information questions were grouped together as were the specific information questions. This grouping allowed a comparison to be made between passive and participatory learning. The results from the tests will help those making the science fair presentations evaluate their materials and methods. Statistical analysis of the results would indicate which questions had a significant change in the number of correct answers between the pre-test and post-test. This information will help the Fair planners and presenters in developing future programs.

  14. Clinical Laboratories – Production Factories or Specialized Diagnostic Centers

    PubMed Central

    Tóth, Judit

    2016-01-01

    Since a large proportion of medical decisions are based on laboratory results, clinical laboratories should meet the increasing demand of clinicians and their patients. Huge central laboratories may process over 10 million tests annually; they act as production factories, measuring emergency and routine tests with sufficient speed and accuracy. At the same time, they also serve as specialized diagnostic centers where well-trained experts analyze and interpret special test results. It is essential to improve and constantly monitor this complex laboratory service, by several methods. Sample transport by pneumatic tube system, use of an advanced laboratory information system and point-of-care testing may result in decreased total turnaround time. The optimization of test ordering may result in a faster and more cost-effective laboratory service. Autovalidation can save time for laboratory specialists, when the analysis of more complex results requires their attention. Small teams of experts responsible for special diagnostic work, and their interpretative reporting according to predetermined principles, may help to minimize subjectivity of these special reports. Although laboratory investigations have become so diversely developed in the past decades, it is essential that the laboratory can provide accurate results relatively quickly, and that laboratory specialists can support the diagnosis and monitoring of patients by adequate interpretation of esoteric laboratory methods. PMID:27683528

  15. No-migration variance petition. Appendices C--J: Volume 5, Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-03-01

    Volume V contains the appendices for: closure and post-closure plans; RCRA ground water monitoring waver; Waste Isolation Division Quality Program Manual; water quality sampling plan; WIPP Environmental Procedures Manual; sample handling and laboratory procedures; data analysis; and Annual Site Environmental Monitoring Report for the Waste Isolation Pilot Plant.

  16. Transport and Development of Microemulsionand Surfactant Stabilized Iron Nanoparticles for In Situ Remediation

    NASA Astrophysics Data System (ADS)

    Hsu, Dennis

    This work describes the mobility assessments of microemulsion-stabilized iron oxide nanoparticles and anionic surfactant sodium diethyl hexyl phosphate (SDEHP)-stabilized nanoscale zero valent iron (NZVI) particles in laboratory porous media. The two formulations tested in this work achieved stable iron nanoparticle suspensions for months and prepared via a simple "one-pot" synthesis method developed by Wang et al. Both formulations were tested under field scale velocity of 5 m/day with no mechanical aid during the injection. A three-compartment model, involving colloid diffusion theory, diffusion theory and tailing was applied to describe the breakthrough curves of the studies. The obtained breakthrough curves of both formulations implied excellent transport in porous media with steady plateau C/Co at 0.8-0.9 and recovery of up to 0.95 for SDEHP stabilized NZVI. Post analysis on the retention of iron on the porous media implied ideal transport with consistent data to the breakthrough curves.

  17. Transferability and inter-laboratory variability assessment of the in vitro bovine oocyte fertilization test.

    PubMed

    Tessaro, Irene; Modina, Silvia C; Crotti, Gabriella; Franciosi, Federica; Colleoni, Silvia; Lodde, Valentina; Galli, Cesare; Lazzari, Giovanna; Luciano, Alberto M

    2015-01-01

    The dramatic increase in the number of animals required for reproductive toxicity testing imposes the validation of alternative methods to reduce the use of laboratory animals. As we previously demonstrated for in vitro maturation test of bovine oocytes, the present study describes the transferability assessment and the inter-laboratory variability of an in vitro test able to identify chemical effects during the process of bovine oocyte fertilization. Eight chemicals with well-known toxic properties (benzo[a]pyrene, busulfan, cadmium chloride, cycloheximide, diethylstilbestrol, ketoconazole, methylacetoacetate, mifepristone/RU-486) were tested in two well-trained laboratories. The statistical analysis demonstrated no differences in the EC50 values for each chemical in within (inter-runs) and in between-laboratory variability of the proposed test. We therefore conclude that the bovine in vitro fertilization test could advance toward the validation process as alternative in vitro method and become part of an integrated testing strategy in order to predict chemical hazards on mammalian fertility. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. 40 CFR 89.411 - Exhaust sample procedure-gaseous components.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and the values recorded. The number of events that may occur between the pre- and post-analysis checks... drift nor the span drift between the pre-analysis and post-analysis checks on any range used may exceed... Emission Test Procedures § 89.411 Exhaust sample procedure—gaseous components. (a) Automatic data...

  19. 40 CFR 89.411 - Exhaust sample procedure-gaseous components.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and the values recorded. The number of events that may occur between the pre- and post-analysis checks... drift nor the span drift between the pre-analysis and post-analysis checks on any range used may exceed... Emission Test Procedures § 89.411 Exhaust sample procedure—gaseous components. (a) Automatic data...

  20. 40 CFR 89.411 - Exhaust sample procedure-gaseous components.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and the values recorded. The number of events that may occur between the pre- and post-analysis checks... drift nor the span drift between the pre-analysis and post-analysis checks on any range used may exceed... Emission Test Procedures § 89.411 Exhaust sample procedure—gaseous components. (a) Automatic data...

  1. 40 CFR 86.1340-90 - Exhaust sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... may occur between the pre and post checks is not specified. However, the difference between pre... pre-analysis and post-analysis checks on any range used may exceed 3 percent for HC, or 2 percent for... Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate Exhaust Test Procedures...

  2. 40 CFR 86.1340-90 - Exhaust sample analysis.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... may occur between the pre and post checks is not specified. However, the difference between pre... pre-analysis and post-analysis checks on any range used may exceed 3 percent for HC, or 2 percent for... Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate Exhaust Test Procedures...

  3. 40 CFR 86.1340-90 - Exhaust sample analysis.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... may occur between the pre and post checks is not specified. However, the difference between pre... pre-analysis and post-analysis checks on any range used may exceed 3 percent for HC, or 2 percent for... Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate Exhaust Test Procedures...

  4. 40 CFR 89.411 - Exhaust sample procedure-gaseous components.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and the values recorded. The number of events that may occur between the pre- and post-analysis checks... drift nor the span drift between the pre-analysis and post-analysis checks on any range used may exceed... Emission Test Procedures § 89.411 Exhaust sample procedure—gaseous components. (a) Automatic data...

  5. 40 CFR 89.411 - Exhaust sample procedure-gaseous components.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and the values recorded. The number of events that may occur between the pre- and post-analysis checks... drift nor the span drift between the pre-analysis and post-analysis checks on any range used may exceed... Emission Test Procedures § 89.411 Exhaust sample procedure—gaseous components. (a) Automatic data...

  6. 40 CFR 86.1340-90 - Exhaust sample analysis.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... may occur between the pre and post checks is not specified. However, the difference between pre... pre-analysis and post-analysis checks on any range used may exceed 3 percent for HC, or 2 percent for... Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate Exhaust Test Procedures...

  7. Reverberation Chamber Uniformity Validation and Radiated Susceptibility Test Procedures for the NASA High Intensity Radiated Fields Laboratory

    NASA Technical Reports Server (NTRS)

    Koppen, Sandra V.; Nguyen, Truong X.; Mielnik, John J.

    2010-01-01

    The NASA Langley Research Center's High Intensity Radiated Fields Laboratory has developed a capability based on the RTCA/DO-160F Section 20 guidelines for radiated electromagnetic susceptibility testing in reverberation chambers. Phase 1 of the test procedure utilizes mode-tuned stirrer techniques and E-field probe measurements to validate chamber uniformity, determines chamber loading effects, and defines a radiated susceptibility test process. The test procedure is segmented into numbered operations that are largely software controlled. This document is intended as a laboratory test reference and includes diagrams of test setups, equipment lists, as well as test results and analysis. Phase 2 of development is discussed.

  8. Training Japanese listeners to identify English /r/ and /l/. III. Long-term retention of new phonetic categories

    PubMed Central

    Lively, Scott E.; Pisoni, David B.; Yamada, Reiko A.; Tohkura, Yoh’ichi; Yamada, Tsuneo

    2012-01-01

    Monolingual speakers of Japanese were trained to identify English /r/ and /l/ using Logan et al.’s [J. Acoust. Soc. Am. 89, 874–886 (1991)] high-variability training procedure. Subjects’ performance improved from the pretest to the post-test and during the 3 weeks of training. Performance during training varied as a function of talker and phonetic environment. Generalization accuracy to new words depended on the voice of the talker producing the /r/–/l/ contrast: Subjects were significantly more accurate when new words were produced by a familiar talker than when new words were produced by an unfamiliar talker. This difference could not be attributed to differences in intelligibility of the stimuli. Three and six months after the conclusion of training, subjects returned to the laboratory and were given the post-test and tests of generalization again. Performance was surprisingly good on each test after 3 months without any further training: Accuracy decreased only 2% from the post-test given at the end of training to the post-test given 3 months later. Similarly, no significant decrease in accuracy was observed for the tests of generalization. After 6 months without training, subjects’ accuracy was still 4.5% above pretest levels. Performance on the tests of generalization did not decrease and significant differences were still observed between talkers. The present results suggest that the high-variability training paradigm encourages a long-term modification of listeners’ phonetic perception. Changes in perception are brought about by shifts in selective attention to the acoustic cues that signal phonetic contrasts. These modifications in attention appear to be retrained over time, despite the fact that listeners are not exposed to the /r/–/l/ contrast in their native language environment. PMID:7963022

  9. Rigidity and retention of ceramic root canal posts.

    PubMed

    Purton, D G; Love, R M; Chandler, N P

    2000-01-01

    Ceramic root-canal posts offer potential advantages over other types with respect to aesthetics and biocompatibility. Any post must be sufficiently rigid and retentive to withstand functional forces. Ceraposts (1.2 mm coronal diameter, ceramic, tapering, smooth posts) and Paraposts (1.25 mm, stainless-steel, parallel, serrated posts) were tested for rigidity by means of a three-point bending test. To test retention in roots, ceramic posts were cemented using one of three protocols: (1) glass-ionomer cement, (2) silane coupling agent and resin cement, or (3) sandblasted post surface, silane coupling agent, and resin cement. Stainless-steel posts were cemented with resin. The tensile force required to dislodge the posts, following four weeks of storage in water, was recorded. Data were compared using Student's t-test and Mann-Whitney U analysis. Ceraposts were significantly more rigid than Paraposts (p < 0.001). Paraposts cemented with resin were significantly more strongly retained than Ceraposts following any cementation protocol (p < 0.001). Retention of the ceramic posts was significantly greater with a silane coupling agent and resin cement than with glass-ionomer cement (p < 0.001). Sandblasting the ceramic posts produced variable results and needs further investigation before it could be recommended.

  10. 41 CFR 101-25.109 - Laboratory and research equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... equipped and/or used for scientific research, testing, or analysis, except clinical laboratories operating... 41 Public Contracts and Property Management 2 2011-07-01 2007-07-01 true Laboratory and research...-General Policies § 101-25.109 Laboratory and research equipment. (a) This section prescribes controls for...

  11. Information and consent in internet paternity testing: focus on minors' protection in Italy.

    PubMed

    Caenazzo, Luciana; Tozzo, Pamela; Benciolini, Paolo; Rodriguez, Daniele

    2008-12-01

    Paternity testing in Italy is usually performed by private laboratories and universities having direct contacts with the applicants. Recently, the number of paternity tests offered through laboratory websites has increased in Italy and Europe. The execution of genetic tests, including paternity testing based on DNA analysis, represents a complex act, which contains three main steps. Paternity analyses carried out by laboratories via Internet are performed on samples collected by the applicants and then mailed back to the laboratories without any patient-physician relationship. Information is given to the subjects through the laboratory's website or mailed with the test order form. The execution of "household" DNA analysis without technical precautions may provide an incorrect response with severe consequences on the individual who has undergone testing, on the family involved, and on society in general. The problems connected with this kind of analysis are not technical, but ethical and deontological. In this work, we will discuss the problems related to information and consent by way of outlining the relevant Italian laws and codes of medical ethics. The Italian Privacy's Guarantor is assessing the ethical and legal implications, but regulations are not yet in place. We believe that adequate information related to this practice cannot be given via Internet, and, consequently, the validity of the consent expressed during this kind of procedure can be uncertain. Further, we will analyze issues regarding the importance of minors' protection when a paternity test is performed via Internet. In our opinion, the complexity of the situations and expectations linked to paternity investigations require a special sensitivity in dealing with each case, based on a patient-physician relationship in the decision-making process especially referring to the defense of the minors' well-being.

  12. Analysis and Presentation of Cumulative Antimicrobial Susceptibility Test Data--The Influence of Different Parameters in a Routine Clinical Microbiology Laboratory.

    PubMed

    Kohlmann, Rebekka; Gatermann, Sören G

    2016-01-01

    Many clinical microbiology laboratories report on cumulative antimicrobial susceptibility testing (cAST) data on a regular basis. Criteria for generation of cAST reports, however, are often obscure and inconsistent. Whereas the CLSI has published a guideline for analysis and presentation of cAST data, national guidelines directed at clinical microbiology laboratories are not available in Europe. Thus, we sought to describe the influence of different parameters in the process of cAST data analysis in the setting of a German routine clinical microbiology laboratory during 2 consecutive years. We developed various program scripts to assess the consequences ensuing from different algorithms for calculation of cumulative antibiograms from the data collected in our clinical microbiology laboratory in 2013 and 2014. One of the most pronounced effects was caused by exclusion of screening cultures for multi-drug resistant organisms which decreased the MRSA rate in some cases to one third. Dependent on the handling of duplicate isolates, i.e. isolates of the same species recovered from successive cultures on the same patient during the time period analyzed, we recorded differences in resistance rates of up to 5 percentage points for S. aureus, E. coli and K. pneumoniae and up to 10 percentage points for P. aeruginosa. Stratification by site of care and specimen type, testing of antimicrobials selectively on resistant isolates, change of interpretation rules and analysis at genus level instead of species level resulted in further changes of calculated antimicrobial resistance rates. The choice of parameters for cAST data analysis may have a substantial influence on calculated antimicrobial resistance rates. Consequently, comparability of cAST reports from different clinical microbiology laboratories may be limited. We suggest that laboratories communicate the strategy used for cAST data analysis as long as national guidelines for standardized cAST data analysis and reporting do not exist in Europe.

  13. Internet-based recruitment system for HIV and STI screening for men who have sex with men in Estonia, 2013: analysis of preliminary outcomes.

    PubMed

    Ruutel, K; Lohmus, L; Janes, J

    2015-04-16

    The aim of the current project was to develop an Internet-based recruitment system for HIV and sexually transmitted infection (STI) screening for men who have sex with men (MSM) in Estonia in order to collect biological samples during behavioural studies. In 2013, an Internet-based HIV risk-behaviour survey was conducted among MSM living in Estonia. After completing the questionnaire, all participants were offered anonymous and free-of-charge STI testing. They could either order a urine sample kit by post to screen for chlamydia infections (including lymphogranuloma venereum (LGV)), trichomoniasis, gonorrhoea and Mycoplasma genitalium infections, or visit a laboratory for HIV, hepatitis A virus, hepatitis B virus,hepatitis C virus and syphilis screening. Of 301 participants who completed the questionnaire, 265 (88%),reported that they were MSM. Of these 265 MSM,68 (26%) underwent various types of testing. In the multiple regression analysis, Russian as the first language,previous HIV testing and living in a city or town increased the odds of testing during the study. Linking Internet-based behavioural data collection with biological sample collection is a promising approach. As there are no specific STI services for MSM in Estonia,this system could also be used as an additional option for anonymous and free-of-charge STI screening.

  14. Full-life chronic toxicity of sodium salts to the mayfly Neocloeon triangulifer in tests with laboratory cultured food.

    PubMed

    Soucek, David J; Dickinson, Amy

    2015-09-01

    Although insects occur in nearly all freshwater ecosystems, few sensitive insect models exist for use in determining the toxicity of contaminants. The objectives of the present study were to adapt previously developed culturing and toxicity testing methods for the mayfly Neocloeon triangulifer (Ephemeroptera: Baetidae), and to further develop a method for chronic toxicity tests spanning organism ages of less than 24 h post hatch to adult emergence, using a laboratory cultured diatom diet. The authors conducted 96-h fed acute tests and full-life chronic toxicity tests with sodium chloride, sodium nitrate, and sodium sulfate. The authors generated 96-h median lethal concentrations (LC50s) of 1062 mg Cl/L (mean of 3 tests), 179 mg N-NO3 /L, and 1227 mg SO4 /L. Acute to chronic ratios ranged from 2.1 to 6.4 for chloride, 2.5 to 5.1 for nitrate, and 2.3 to 8.5 for sulfate. The endpoints related to survival and development time were consistently the most sensitive in the tests. The chronic values generated for chloride were in the same range as those generated by others using natural foods. Furthermore, our weight-versus-fecundity plots were similar to those previously published using the food culturing method on which the present authors' method was based, indicating good potential for standardization. The authors believe that the continued use of this sensitive mayfly species in laboratory studies will help to close the gap in understanding between standard laboratory toxicity test results and field-based observations of community impairment. © 2015 SETAC.

  15. 40 CFR 80.126 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...% independent lab testing, the laboratory analysis shall consist of the results reported to the refinery or... trading records shall include worksheets and EPA reports showing actual and complying totals for benzene... evidencing the transfer of credits. (c) Designation records shall include laboratory analysis reports that...

  16. 40 CFR 80.126 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...% independent lab testing, the laboratory analysis shall consist of the results reported to the refinery or... trading records shall include worksheets and EPA reports showing actual and complying totals for benzene... evidencing the transfer of credits. (c) Designation records shall include laboratory analysis reports that...

  17. Kepler's Laws in an Introductory Astronomy Laboratory: The Influence of a Computer-based Simulation Used With Multiple Variables

    NASA Astrophysics Data System (ADS)

    Ruzhitskaya, Lanika; French, R. S.; Speck, A.

    2009-05-01

    We report first results from a multi-faceted study employing the lab "Revolution of the Moons of Jupiter" from the CLEA group (Contemporary Laboratory Experiences in Astronomy) in an introductory astronomy laboratory course for nonscience majors. Four laboratory sections participated in the study: two at a traditional four-year public institution in Missouri and two at a two-year community college in California. Students in all sections took identical pre- and post-tests and used the same simulation software. In all sections, students were assigned randomly to work either in pairs or individually. One section at both schools was given a brief mini-lecture on Kepler's laws and introduction to the exercise while the other section at both schools was given no instructions whatsoever. The data allow comparisons between the impact of the simulation with and without instructions and on the influences of peer interactions on learning outcomes.

  18. A laboratory silicone for preclinical training in ear prosthesis.

    PubMed

    Anand, Vijay; Haribabu; Vimala; Gnanasamband, Vimala

    2013-07-01

    This article describes an industrial elastic silicone as a material for the laboratory fabrication of ear prosthesis. It has been tested for toxicity in lab animals by the SGS India Pvt. Ltd and approved as a material to pass the parameter of abnormal toxicity. This material therefore can be safely recommended for laboratory exercise to fabricate facial prosthesis. The high cost of the maxillo facial silicone materials prohibits their use for facial prosthesis in pre-clinical training of post-graduate students in maxillofacial prosthodontics. For this reason, pre-clinical laboratory exercise in facial prosthesis is inadequate. A few institutions use polymethyl methacrylate resins which are rigid and do not have elastic characteristics of silicone, which is used for facial defects. This cost-effective industrial silicone material which mimics the elastic and color characteristics of the conventional silicones can be recommended for preclinical exercises.

  19. Characterization of irradiated AISI 316L stainless steel disks removed from the Spallation Neutron Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vevera, Bradley J; Hyres, James W; McClintock, David A

    2014-01-01

    Irradiated AISI 316L stainless steel disks were removed from the Spallation Neutron Source (SNS) for post-irradiation examination (PIE) to assess mechanical property changes due to radiation damage and erosion of the target vessel. Topics reviewed include high-resolution photography of the disk specimens, cleaning to remove mercury (Hg) residue and surface oxides, profile mapping of cavitation pits using high frequency ultrasonic testing (UT), high-resolution surface replication, and machining of test specimens using wire electrical discharge machining (EDM), tensile testing, Rockwell Superficial hardness testing, Vickers microhardness testing, scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS). The effectiveness of the cleaning proceduremore » was evident in the pre- and post-cleaning photography and permitted accurate placement of the test specimens on the disks. Due to the limited amount of material available and the unique geometry of the disks, machine fixturing and test specimen design were critical aspects of this work. Multiple designs were considered and refined during mock-up test runs on unirradiated disks. The techniques used to successfully machine and test the various specimens will be presented along with a summary of important findings from the laboratory examinations.« less

  20. CAP/ACMG proficiency testing for biochemical genetics laboratories: a summary of performance.

    PubMed

    Oglesbee, Devin; Cowan, Tina M; Pasquali, Marzia; Wood, Timothy C; Weck, Karen E; Long, Thomas; Palomaki, Glenn E

    2018-01-01

    PurposeTesting for inborn errors of metabolism is performed by clinical laboratories worldwide, each utilizing laboratory-developed procedures. We sought to summarize performance in the College of American Pathologists' (CAP) proficiency testing (PT) program and identify opportunities for improving laboratory quality. When evaluating PT data, we focused on a subset of laboratories that have participated in at least one survey since 2010.MethodsAn analysis of laboratory performance (2004 to 2014) on the Biochemical Genetics PT Surveys, a program administered by CAP and the American College of Medical Genetics and Genomics. Analytical and interpretive performance was evaluated for four tests: amino acids, organic acids, acylcarnitines, and mucopolysaccharides.ResultsSince 2010, 150 laboratories have participated in at least one of four PT surveys. Analytic sensitivities ranged from 88.2 to 93.4%, while clinical sensitivities ranged from 82.4 to 91.0%. Performance was higher for US participants and for more recent challenges. Performance was lower for challenges with subtle findings or complex analytical patterns.ConclusionUS clinical biochemical genetics laboratory proficiency is satisfactory, with a minority of laboratories accounting for the majority of errors. Our findings underscore the complex nature of clinical biochemical genetics testing and highlight the necessity of continuous quality management.

Top