Flanagan, Dennis
2008-01-01
This is a case report of the restoration of a partially edentulous atrophic anterior maxilla and atrophic mandibular posterior ridges. This case report demonstrates one method for successful treatment of partial edentulism at No. 7 to 10, where interlock attachments on natural cuspids and mini dental implants support an acrylic-based screwless fixed detachable partial denture to provide lip support and masticatory function in the anterior maxilla. The presenting qualities of this case were similar to combination syndrome.
Treatment planning of implants in posterior quadrants.
Jivraj, S; Chee, W
2006-07-08
Differences in anatomy and biomechanics make treatment of posterior quadrants with dental implants substantially different to that of anterior areas. Without implants, when posterior teeth were lost, treatment options included a long span fixed partial denture or a removable prosthesis, especially when no terminal abutment was available. Today, with the use of implants, options are available that allow preservation of unrestored teeth.(1) When teeth are missing, implant supported restorations can be considered the treatment of choice from the perspective of occlusal support, preservation of adjacent teeth and avoidance of a removable partial denture.
Abdurahiman, V T; Abdul Khader, M; Sanju John Jolly
2013-12-01
Treating partial edentulousness forms a major share of prosthodontic clinical practice. The purpose of this study was to find out the frequency of partial edentulism, its arch distribution status, awareness to restore, and the ratio of removable to fixed prosthesis among a student sample aged 18-25 years. The methodology selected was a questionnaire survey followed by clinical examination of the student community from Tirur taluk, Malappuram district, Kerala. The results showed that the frequency of partial edentulism among the surveyed group was significant with predominance in maxillary posterior edentulousness in men and mandibular posterior edentulousness in women. Though there was not any significant gender difference in the partial edentulism, women were more aware than men to restore it. All restored cases were with fixed bridges and no anterior edentulousness was found. The study also revealed a lack of awareness and need to educate the population.
Fracture Surface Analysis of Clinically Failed Fixed Partial Dentures
Taskonak, B.; Mecholsky, J.J.; Anusavice, K.J.
2008-01-01
Ceramic systems have limited long-term fracture resistance, especially when they are used in posterior areas or for fixed partial dentures. The objective of this study was to determine the site of crack initiation and the causes of fracture of clinically failed ceramic fixed partial dentures. Six Empress 2® lithia-disilicate (Li2O·2SiO2)-based veneered bridges and 7 experimental lithia-disilicate-based non-veneered ceramic bridges were retrieved and analyzed. Fractography and fracture mechanics methods were used to estimate the stresses at failure in 6 bridges (50%) whose fracture initiated from the occlusal surface of the connectors. Fracture of 1 non-veneered bridge (8%) initiated within the gingival surface of the connector. Three veneered bridges fractured within the veneer layers. Failure stresses of the all-core fixed partial dentures ranged from 107 to 161 MPa. Failure stresses of the veneered fixed partial dentures ranged from 19 to 68 MPa. We conclude that fracture initiation sites are controlled primarily by contact damage. PMID:16498078
López-Suárez, Carlos; Gonzalo, Esther; Peláez, Jesús; Rodríguez, Verónica
2015-01-01
Background In recent years there has been an improvement of zirconia ceramic materials to replace posterior missing teeth. To date little in vitro studies has been carried out on the fracture resistance of zirconia veneered posterior fixed dental prostheses. This study investigated the fracture resistance and the failure mode of 3-unit zirconia-based posterior fixed dental prostheses fabricated with two CAD/CAM systems. Material and Methods Twenty posterior fixed dental prostheses were studied. Samples were randomly divided into two groups (n=10 each) according to the zirconia ceramic analyzed: Lava and Procera. Specimens were loaded until fracture under static load. Data were analyzed using Wilcoxon´s rank sum test and Wilcoxon´s signed-rank test (P<0.05). Results Partial fracture of the veneering porcelain occurred in 100% of the samples. Within each group, significant differences were shown between the veneering and the framework fracture resistance (P=0.002). The failure occurred in the connector cervical area in 80% of the cases. Conclusions All fracture load values of the zirconia frameworks could be considered clinically acceptable. The connector area is the weak point of the restorations. Key words:Fixed dental prostheses, zirconium-dioxide, zirconia, fracture resistance, failure mode. PMID:26155341
Schwarzkopf, Ran; Woolwine, Spencer; Josephs, Lee; Scott, Richard D
2015-12-01
Posterior cruciate ligament (PCL) release may be required to balance the flexion gap in PCL retaining TKA. This study examines the incidence and functional consequences of PCL release in both fixed and mobile bearing TKA. A consecutive series of 1388 TKAs with 1014 fixed bearing, and 374 mobile bearing implants were reviewed for prevalence of partial PCL release, restoration of potential flexion and objective knee stability at minimum one-year follow-up. Patients receiving mobile bearing inserts were more likely to need partial PCL release (42% versus 17.5%). The occurrence of partial PCL release did not have a significant impact on knee range of motion and subjective knee stability. The need for a partial PCL release appears to be greater in mobile than in fixed bearing. Knees that required a release in both groups demonstrated no difference in restoration of flexion compared with unreleased knees and no adverse effects on flexion stability. Copyright © 2015 Elsevier Inc. All rights reserved.
Prabhu, Radhakrishnan; Prabhu, Geetha; Baskaran, Eswaran; Arumugam, Eswaran M
2016-01-01
In recent years, direct metal laser sintered (DMLS) metal-ceramic-based fixed partial denture prostheses have been used as an alternative to conventional metal-ceramic fixed partial denture prostheses. However, clinical studies for evaluating their long-term clinical survivability and acceptability are limited. The aim of this study was to assess the efficacy of metal-ceramic fixed dental prosthesis fabricated with DMLS technique, and its clinical acceptance on long-term clinical use. The study group consisted of 45 patients who were restored with posterior three-unit fixed partial denture prosthesis made using direct laser sintered metal-ceramic restorations. Patient recall and clinical examination of the restorations were done after 6months and every 12 months thereafter for the period of 60 months. Clinical examination for evaluation of longevity of restorations was done using modified Ryge criteria which included chipping of the veneered ceramic, connector failure occurring in the fixed partial denture prosthesis, discoloration at the marginal areas of the veneered ceramic, and marginal adaptation of the metal and ceramic of the fixed denture prosthesis. Periapical status was assessed using periodical radiographs during the study period. Survival analysis was made using the Kaplan-Meier method. None of the patients had failure of the connector of the fixed partial denture prostheses during the study period. Two exhibited biological changes which included periapical changes and proximal caries adjacent to the abutments. DMLS metal-ceramic fixed partial denture prosthesis had a survival rate of 95.5% and yielded promising results during the 5-year clinical study.
Prabhu, Radhakrishnan; Prabhu, Geetha; Baskaran, Eswaran; Arumugam, Eswaran M.
2016-01-01
Statement of Problem: In recent years, direct metal laser sintered (DMLS) metal-ceramic-based fixed partial denture prostheses have been used as an alternative to conventional metal-ceramic fixed partial denture prostheses. However, clinical studies for evaluating their long-term clinical survivability and acceptability are limited. Aims and Objective: The aim of this study was to assess the efficacy of metal-ceramic fixed dental prosthesis fabricated with DMLS technique, and its clinical acceptance on long-term clinical use. Materials and Methods: The study group consisted of 45 patients who were restored with posterior three-unit fixed partial denture prosthesis made using direct laser sintered metal-ceramic restorations. Patient recall and clinical examination of the restorations were done after 6months and every 12 months thereafter for the period of 60 months. Clinical examination for evaluation of longevity of restorations was done using modified Ryge criteria which included chipping of the veneered ceramic, connector failure occurring in the fixed partial denture prosthesis, discoloration at the marginal areas of the veneered ceramic, and marginal adaptation of the metal and ceramic of the fixed denture prosthesis. Periapical status was assessed using periodical radiographs during the study period. Survival analysis was made using the Kaplan–Meier method. Results: None of the patients had failure of the connector of the fixed partial denture prostheses during the study period. Two exhibited biological changes which included periapical changes and proximal caries adjacent to the abutments. Conclusion: DMLS metal-ceramic fixed partial denture prosthesis had a survival rate of 95.5% and yielded promising results during the 5-year clinical study. PMID:27141171
[Classification and Treatment of Sacroiliac Joint Dislocation].
Tan, Zhen; Huang, Zhong; Li, Liang; Meng, Wei-Kun; Liu, Lei; Zhang, Hui; Wang, Guang-Lin; Huang, Fu-Guo
2017-09-01
To develop a renewed classification and treatment regimen for sacroiliac joint dislocation. According to the direction of dislocation of sacroiliac joint,combined iliac,sacral fractures,and fracture morphology,sacroiliac joint dislocation was classified into 4 types. Type Ⅰ (sacroiliac anterior dislocation): main fracture fragments of posterior iliac wing dislocated in front of sacroiliac joint. Type Ⅱ (sacroiliac posterior dislocation): main fracture fragments of posterior iliac wing dislocated in posterior of sacroiliac joint. Type Ⅲ (Crescent fracturedislocation of the sacroiliac joint): upward dislocation of posterior iliac wing with oblique fracture through posterior iliac wing. Type ⅢA: a large crescent fragment and dislocation comprises no more than onethird of sacroiliac joint,which is typically inferior. Type ⅢB: intermediatesize crescent fragment and dislocation comprises between one and twothirds of joint. Type ⅢC: a small crescent fragment where dislocation comprises most,but not the entire joint. Different treatment regimens were selected for different types of fractures. Treatment for type Ⅰ sacroiliac joint dislocation: anterior iliac fossa approach pry stripping reset; sacroiliac joint fixed with sacroiliac screw through percutaneous. Treatment for type Ⅱ sacroiliac joint dislocation: posterior sacroiliac joint posterior approach; sacroiliac joint fixed with sacroiliac screw under computer guidance. Treatment for type ⅢA and ⅢB sacroiliac joint dislocation: posterior sacroiliac joint approach; sacroiliac joint fixed with reconstruction plate. Treatment for type ⅢC sacroiliac joint dislocation: sacroiliac joint closed reduction; sacroiliac joint fixed with sacroiliac screw through percutaneous. Treatment for type Ⅳ sacroiliac joint dislocation: posterior approach; sacroiliac joint fixed with spinal pelvic fixation. Results of 24 to 72 months patient follow-up (mean 34.5 months): 100% survival,100% wound healing,and 100% fracture healing. Two cases were identified as type Ⅰ sacroiliac joint dislocation,including one with coexistence of nerve injury. Patients recovered completely 12 months after surgery. Eight cases were identified as type Ⅱ sacroiliac joint dislocation; none had obvious nerve injury during treatments. Twelve cases were identified as type Ⅲ sacroiliac joint dislocation,including one with coexistence of nerve injury. Patients recovered completely 12 months after surgery. Three cases were identified as type Ⅳ sacroiliac joint dislocation with coexistence of nerve injury. Two patients fully recovered 12 months after surgery. One had partial recovery of neurological function. The classification and treatment regimen for sacroiliac joint dislocation have achieved better therapeutic effect,which is worth promoting.
Pieri, Francesco; Forlivesi, Caterina; Caselli, Ernesto; Corinaldesi, Giuseppe
2017-04-01
Evidence concerning predictability of narrow-diameter implants (NDIs) (<3.3 mm) to restore partially edentulous posterior maxillary and mandibular areas is limited. The aim of this study is to compare the 5-year outcomes of NDIs (3.0 mm) and standard-diameter implants (SDIs) (4.0 to 4.5 mm) supporting fixed partial dentures (FPDs) in posterior mandibular and maxillary jaws. All patients treated with at least two adjacent NDIs or SDIs according to available bone thickness and with a minimum follow-up of 5 years after placement were invited to undergo a clinical and radiologic examination. Outcome measures were implant and FPD failures, biologic and prosthetic complications, and marginal bone loss. A total of 107 out of 127 patients attended the examination: 49 (113 implants) of the NDI group, and 58 (126 implants) of the SDI group. Two NDIs failed in one patient versus four SDIs in four patients (P = 0.37). One FPD failed in the NDI group versus two FPDs in the SDI group (P >0.99). Nine biologic complications occurred in the NDI group and twelve in the SDI group (P = 0.81). Twelve prosthetic complications occurred in the NDI group and only two in the SDI group (P = 0.001). Peri-implant marginal bone loss at 5 years was 0.95 ± 0.84 mm for the NDI group and 1.2 ± 0.86 mm for the SDI group (P = 0.06). Five-year data indicate that FPD treatment in posterior mandibular and maxillary jaws with NDIs was as reliable as with SDIs, although NDIs showed a higher risk of prosthetic complications.
Vaidya, Sharad; Kapoor, Charu; Bakshi, Yujika; Bhalla, Sonam
2015-01-01
Satisfactory restoration in a patient with a partially edentulous situation can be challenging especially when unilateral or bilateral posterior segment of teeth is missing. Successful restoration can be done with various conventional and contemporary treatment options. One such treatment modality is attachment-retained cast partial dentures. A key to success for an attachment retained cast partial denture is the strategic selection of teeth for retention. This clinical report discusses rehabilitation of a patient with the help of a combined prosthesis in the upper arch and stud retained overdenture in the lower arch. PMID:26929527
Survival of various implant-supported prosthesis designs following 36 months of clinical function.
Rodriguez, A M; Orenstein, I H; Morris, H F; Ochi, S
2000-12-01
The use of endosseous dental implants to replace natural teeth lost to trauma, dental caries, or periodontal disease has become a predictable form of prosthetic treatment since gaining popularity in the early 1980s. While numerous clinical studies have focused on the survival of implants, few address the survival of different prosthesis designs. Beginning in 1991, 882 prostheses supported by more than 2,900 implants (687 patients) were placed by the Department of Veterans Affairs Dental Implant Clinical Research Group (DICRG). These prostheses were divided into five research strata based on arch location. The recommended design for each stratum was: bar-supported overdenture (maxillary completely edentulous); screw-retained hybrid denture (mandibular completely edentulous); screw-retained fixed partial denture (mandibular and maxillary posterior partially edentulous); and cemented single crown (maxillary anterior single tooth). Alternative overdenture designs were utilized in the edentulous arches when the recommended prosthesis could not be fabricated. Prosthesis success rates for the research strata were calculated for an observation time of up to 36 months following prosthesis placement. Success rates for the maxillary edentulous stratum ranged from 94.6% for the bar-retained overdenture supported by five to six fixtures to 81.8% for the cap-retained overdenture. The mandibular edentulous strata produced success rates of 98.1% for the fixed hybrid prosthesis to 91.7% for the cap-retained prosthesis. Success rates for maxillary and mandibular posterior fixed partial dentures were 94.3% and 92.6%, respectively, while the maxillary anterior single-tooth prosthesis yielded a success rate of 98.1% for the 36-month observation period. The recommended prosthesis designs investigated in this study proved to be reliable, with encouraging success rates for an observation period of 36 months following placement.
2017-01-01
PURPOSE The aim of this study was to determine the influence of long base lengths of a fixed partial denture (FPD) to rotational resistance with variation of vertical wall angulation. MATERIALS AND METHODS Trigonometric calculations were done to determine the maximum wall angle needed to resist rotational displacement of an experimental-FPD model in 2-dimensional plane. The maximum wall angle calculation determines the greatest taper that resists rotation. Two different axes of rotation were used to test this model with five vertical abutment heights of 3-, 3.5-, 4-, 4.5-, and 5-mm. The two rotational axes were located on the mesial-side of the anterior abutment and the distal-side of the posterior abutment. Rotation of the FPD around the anterior axis was counter-clockwise, Posterior-Anterior (P-A) and clockwise, Anterior-Posterior (A-P) around the distal axis in the sagittal plane. RESULTS Low levels of vertical wall taper, ≤ 10-degrees, were needed to resist rotational displacement in all wall height categories; 2–to–6–degrees is generally considered ideal, with 7–to–10–degrees as favorable to the long axis of the abutment. Rotation around both axes demonstrated that two axial walls of the FPD resisted rotational displacement in each direction. In addition, uneven abutment height combinations required the lowest wall angulations to achieve resistance in this study. CONCLUSION The vertical height and angulation of FPD abutments, two rotational axes, and the long base lengths all play a role in FPD resistance form. PMID:28874995
Choi, Nam-Hong; Kim, Byeong-Yeon; Hwang Bo, Byung-Hun; Victoroff, Brian N
2014-10-01
To compare meniscal healing and functional outcomes after all-inside meniscal repair between sutures and meniscal fixation devices. Sixty patients with a tear within the red-red or red-white zones of the posterior horn of the medial or lateral meniscus in conjunction with an anterior cruciate ligament (ACL) tear were included in this study. Meniscal repairs were performed with sutures in 35 patients and the FasT-Fix device (Smith & Nephew Endoscopy, Andover, MA) in 25 patients concomitantly with hamstring ACL reconstruction. Postoperative evaluations included Lysholm knee score, Tegner activity scale, Lachman and pivot-shift tests, and KT-1000 arthrometer (MEDmetric, San Diego, CA) testing. Follow-up magnetic resonance imaging (MRI) scans were obtained postoperatively for all patients to evaluate meniscal healing. The mean follow-up period was 47.2 months. In the suture group, 31 patients (86.1%) were asymptomatic and 4 (13.9%) were symptomatic. In the FasT-Fix group, 20 patients (80%) were asymptomatic and 5 (20%) were symptomatic. Postoperative functional evaluation and knee stability showed no statistically significant difference between the 2 groups. Follow-up MRI showed that 26 menisci (74.3%) were healed, 3 menisci (8.6%) were partially healed, and 6 menisci (17.1%) were not healed in the suture group. In the FasT-Fix group, 15 menisci (64%) were healed, 7 menisci (24%) were partially healed, and 3 menisci (12%) were not healed. Follow-up MRI showed no statistically significant difference between the 2 groups. In the FasT-Fix group, follow-up MRI showed a newly developed cyst posterior to the medial meniscus in 2 patients. A new tear anterior to the previous tear was found in 1 patient. In the suture group, follow-up MRI showed no cysts or new tears. All-inside meniscal repairs using either sutures or the FasT-Fix device showed satisfactory results in patients with concomitant hamstring ACL reconstruction. There was no statistically significant difference in meniscal healing evaluated by MRI and functional outcomes between the 2 techniques. Level III, retrospective comparative study. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Yoshihara, Hiroyuki; Abumi, Kuniyoshi; Ito, Manabu; Kotani, Yoshihisa; Sudo, Hideki; Takahata, Masahiko
2013-11-01
Surgical treatment for severe circumferentially fixed cervical kyphosis has been challenging. Both anterior and posterior releases are necessary to provide the cervical mobility necessary for fusion in a corrected position. In two case reports, we describe the circumferential osteotomy of anterior-posterior-anterior surgical sequence, and the efficacy of this technique when cervical pedicle screw fixation for severe fixed cervical kyphosis is used. Etiology of fixed cervical kyphosis was unknown in one patient and neurofibromatosis in one patient. Both patients had severe fixed cervical kyphosis as determined by cervical radiographs and underwent circumferential osteotomy and fixation via an anterior-posterior-anterior surgical sequence and correction of kyphosis by pedicle screw fixation. Severe fixed cervical kyphosis was treated successfully by the use of circumferential osteotomy and pedicle screw fixation. The surgical sequence described in this report is a reasonable approach for severe circumferentially fixed cervical kyphosis and short segment fixation can be achieved using pedicle screws. Copyright © 2013 Elsevier Inc. All rights reserved.
Graves, Stephen; Sedrakyan, Art; Baste, Valborg; Gioe, Terence J; Namba, Robert; Martínez Cruz, Olga; Stea, Susanna; Paxton, Elizabeth; Banerjee, Samprit; Isaacs, Abby J; Robertsson, Otto
2014-12-17
Posterior-stabilized total knee prostheses were introduced to address instability secondary to loss of posterior cruciate ligament function, and they have either fixed or mobile bearings. Mobile bearings were developed to improve the function and longevity of total knee prostheses. In this study, the International Consortium of Orthopaedic Registries used a distributed health data network to study a large cohort of posterior-stabilized prostheses to determine if the outcome of a posterior-stabilized total knee prosthesis differs depending on whether it has a fixed or mobile-bearing design. Aggregated registry data were collected with a distributed health data network that was developed by the International Consortium of Orthopaedic Registries to reduce barriers to participation (e.g., security, proprietary, legal, and privacy issues) that have the potential to occur with the alternate centralized data warehouse approach. A distributed health data network is a decentralized model that allows secure storage and analysis of data from different registries. Each registry provided data on mobile and fixed-bearing posterior-stabilized prostheses implanted between 2001 and 2010. Only prostheses associated with primary total knee arthroplasties performed for the treatment of osteoarthritis were included. Prostheses with all types of fixation were included except for those with the rarely used reverse hybrid (cementless tibial and cemented femoral components) fixation. The use of patellar resurfacing was reported. The outcome of interest was time to first revision (for any reason). Multivariate meta-analysis was performed with linear mixed models with survival probability as the unit of analysis. This study includes 137,616 posterior-stabilized knee prostheses; 62% were in female patients, and 17.6% had a mobile bearing. The results of the fixed-effects model indicate that in the first year the mobile-bearing posterior-stabilized prostheses had a significantly higher hazard ratio (1.86) than did the fixed-bearing posterior-stabilized prostheses (95% confidence interval, 1.28 to 2.7; p = 0.001). For all other time intervals, the mobile-bearing posterior-stabilized prostheses had higher hazard ratios; however, these differences were not significant. Mobile-bearing posterior-stabilized prostheses had an increased rate of revision compared with fixed-bearing posterior-stabilized prostheses. This difference was evident in the first year. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Jang, Ki-Mo; Ahn, Jin Hwan; Wang, Joon Ho
2012-03-07
This article describes a case of an arthroscopic partial meniscectomy of a posteriorly flipped superior leaflet in a horizontal medial meniscus tear using the posterior transseptal portal. An arthroscopic partial meniscectomy for bucket handle or flap tears in medial or lateral compartments using ordinary portals is a relatively common procedure in irreparable cases. However, the posterior compartment of the knee is not readily accessible through ordinary arthroscopic portals. Therefore, it has been considered a blind spot. Through the posterior transseptal portal, surgeons can achieve excellent arthroscopic visualization of the posterior compartment and easily perform arthroscopic procedures of the posterior compartment of the knee. A 48-year-old woman presented with a 1-year history of pain in the medial aspect of the right knee joint. Preoperative magnetic resonance imaging revealed a thinning of the medial meniscus posterior horn in coronal images and a sharp-edged triangle arising from the medial meniscus posterior horn between the medial femoral condyle and medial meniscus posterior horn on sagittal images (flipped-over sign). During the arthroscopic procedure, we found that the flipped leaflet was displaced posteriorly and was not mobile between the medial femoral condyle and medial meniscus posterior horn. Partial meniscectomy for a posteriorly displaced fragment can be performed successfully using the posterior transseptal portal. The posterior transseptal portal is useful for an arthroscopic partial meniscectomy of a posteriorly flipped leaflet in the posterior compartment of the knee. Copyright 2012, SLACK Incorporated.
Mcdonald, E; Theologis, A A; Horst, P; Kandemir, U; Pekmezci, M
2015-12-01
This study aimed at evaluating the additional stability that is provided by anterior external and internal fixators in an unstable pelvic fracture model (OTA 61-C). An unstable pelvic fracture (OTA 61-C) was created in 27 synthetic pelves by making a 5-mm gap through the sacral foramina (posterior injury) and an ipsilateral pubic rami fracture (anterior injury). The posterior injury was fixed with either a single iliosacral (IS) screw, a single trans-iliac, trans-sacral (TS) screw, or two iliosacral screws (S1S2). Two anterior fixation techniques were utilized: external fixation (Ex-Fix) and supra-acetabular external fixation and internal fixation (In-Fix); supra-acetabular pedicle screws connected with a single subcutaneous spinal rod. The specimens were tested using a nondestructive single-leg stance model. Peak-to-peak (P2P) displacement and rotation and conditioning displacement (CD) were calculated. The Ex-Fix group failed in 83.3 % of specimens with concomitant single-level posterior fixation (Total: 15/18-7 of 9 IS fixation, 8 of 9 TS fixation), and 0 % (0/9) of specimens with concomitant two-level (S1S2) posterior fixation. All specimens with the In-Fix survived testing except for two specimens treated with In-Fix combined with IS fixation. Trans-sacral fixation had higher pubic rotation and greater sacral and pubic displacement than S1S2 (p < 0.05). Rotation of the pubis and sacrum was not different between In-Fix constructs combined with single-level IS and TS fixation. In this model of an unstable pelvic fracture (OTA 61-C), anterior fixation with an In-Fix was biomechanically superior to an anterior Ex-Fix in the setting of single-level posterior fixation. There was no biomechanical difference between the In-Fix and Ex-Fix when each was combined with two levels of posterior sacral fixation.
Kroeplin, Birgit S; Strub, Joerg R
2011-01-01
The aim of this study was to describe the didactic and clinical undergraduate implant dentistry program of the Albert-Ludwigs University, Freiburg, Germany, with emphasis on the clinical implant experience. A detailed description of the implant curriculum at Albert-Ludwigs University is given with documented exemplary cases and additional flow charts. All students participate in 28 hours of lectures and approximately 64 hours of seminars with hands-on courses and gain clinical experience. All undergraduate students are eligible to place and restore oral implants. Emphasis is placed on prosthetic-driven planning of implant positions, three-dimensional imaging, and computer-guided implant placement. Implant restorations performed by undergraduate students comprise single crowns and small multiunit fixed dental prostheses in partially edentulous posterior maxillae and anterior or posterior mandibles, implant-retained overdentures (snap attachment) in edentulous patients, and telescopic fixed-removable dental prostheses on remaining teeth and strategically placed additional implants. Over the past 2.5 years, 51 patients were treated with 97 dental implants placed by students in the undergraduate program. Seventy-one restorations were inserted: 60.6% single crowns, 7% fixed dental protheses, 21.1% overdentures, and 11.3% telescopic fixed-removable dental prostheses. The implant survival rate was 98.9%. Because survival rates for dental implants placed and restored by students are comparable to those of experienced dentists, oral implant dentistry should be implemented as part of the undergraduate dental curriculum.
Mazaro, José Vitor Quinelli; Filho, Humberto Gennari; Vedovatto, Eduardo; Pellizzer, Eduardo Piza; Rezende, Maria Cristina Rosifini Alves; Zavanelli, Adriana Cristina
2011-11-01
The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 × 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.
Management of long-standing partially torn and flipped laser in situ keratomileusis flaps.
Kim, Jin Sun; Chung, Byunghoon; Lee, Taekjune; Kim, Woon Cho; Kim, Tae-im; Kim, Eung Kweon
2015-02-01
We describe 2 cases of traumatized and torn laser in situ keratomileusis (LASIK) flaps, partially flipped anteriorly or posteriorly, fixed for 8 months or 4 months, and accompanied by epithelial ingrowth. The 2 patients had had uneventful bilateral LASIK 6 years and 1 year before the trauma. In Case 1, the anteriorly flipped flap was removed with transepithelial phototherapeutic keratectomy. Next, mitomycin-C 0.04% was applied for 30 seconds. In Case 2, the portion of the flap that was flipped posteriorly and buried under the remaining intact LASIK flap was restored to its original normal position and epithelial ingrowth was removed mechanically with a microcurette. Irrigation with 20% ethanol was performed to inhibit the recurrence of interfacial epithelial ingrowth. The stretched amniotic membrane overlay over the cornea and sclera was sutured tightly to the episclera as the biologic pressure patch for the inhibition of epithelial re-ingrowth. Good visual acuity was restored in both cases. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Fujii, Masataka; Furumatsu, Takayuki; Kodama, Yuya; Miyazawa, Shinichi; Hino, Tomohito; Kamatsuki, Yusuke; Yamada, Kazuki; Ozaki, Toshifumi
2017-05-01
Medial meniscus posterior root has an important role in the maintenance of knee articular cartilage. Although pullout repair of the medial meniscus posterior root tear has become a gold standard, it has several difficulties for suturing. We have developed a modified Mason-Allen suture technique using the FasT-Fix all-inside suture device combined with Ultrabraid. The present suture technique allows a strong grasping of the medial meniscus posterior horn for arthroscopic pullout repair.
Raigrodski, Ariel J; Yu, Alika; Chiche, Gerard J; Hochstedler, J L; Mancl, Lloyd A; Mohamed, Shawky E
2012-10-01
In recent years, zirconium dioxide-based partial fixed dental prostheses (FDP) have been suggested as an alternative treatment to traditional metal ceramic FDPs. However, clinical studies evaluating their longevity and related complications are limited. The purpose of this cohort clinical study was to assess the efficacy of zirconium dioxide-based posterior 3-unit FDPs. Twenty 3-unit posterior FDPs (Lava) were placed in 16 participants missing a second premolar or a first molar. All participants met specific inclusion and exclusion criteria and provided informed consent. All teeth were prepared in a standardized manner: occlusal reduction of 1.5 to 2 mm; axial reduction of 1 to 1.5 mm; a 1.0 mm 360-degree rounded shoulder placed 0.5 mm subgingivally on the facial aspect and supragingivally on the lingual aspect on sound tooth structure; and rounded internal line angles. Definitive impressions were made with vinyl polysiloxane impression material. Frameworks were fabricated by using computer-aided design and computer-aided manufacturing (CAD/CAM) technology with a uniform retainer thickness of 0.6 mm and a minimal connector surface area of 9 mm(2). Restorations were luted with resin-modified glass ionomer cement (Rely-X Luting). Participants were recalled at 2 weeks, 6 months, and 12 months, and thereafter, annually for up to 60 months. Clinical fracture measurements, marginal discoloration, marginal adaptation, radiographic proximal recurrent caries, and periapical pathoses were assessed over time by using modified Ryge criteria. The probability distributions of these variables were calculated for the baseline data and for the recall data. An analysis of survival was made by using the Kaplan-Meier method. Eighteen FDPs were clinically evaluated at 5 years and 1 at 48 months. Fifteen were rated Alpha for fracture measurements, and 2 were rated Bravo (minor chipping of veneering porcelain and not requiring restoration replacement). Two were rated Charlie (major chipping of veneering porcelain and requiring restoration replacement). Eighteen FDPs were rated Alpha for marginal integrity, and 1 rated Bravo. All restorations were rated Alpha for marginal discoloration. One participant experienced root fracture after 60 months, while another was treated surgically for a periapical pathosis on an endodontically treated abutment. Zirconium dioxide-based posterior 3-unit FDPs performed well after 5 years of service. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Kodama, Y; Furumatsu, T; Fujii, M; Tanaka, T; Miyazawa, S; Ozaki, T
2016-11-01
A medial meniscus posterior root tear (MMPRT) may increase the tibiofemoral contact pressure by decreasing the tibiofemoral contact area. Meniscal dysfunction induced by posterior root injury may lead to the development of osteoarthritic knees. Repair of a MMPRT can restore medial meniscus (MM) function and prevent knee osteoarthritis progression. Several surgical procedures have been reported for treating a MMPRT. However, these procedures are associated with several technical difficulties. Here, we describe a technique to stabilize a torn MM posterior root using the FasT-Fix ® all-inside meniscal suture device and a new aiming device. The uncut free-end of the FasT-Fix ® suture can be used as a thread for transtibial pullout repair. Our procedure might help overcome the technical difficulties in arthroscopic treatment of a MMPRT. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Comfort, Thomas; Baste, Valborg; Froufe, Miquel Angel; Namba, Robert; Bordini, Barbara; Robertsson, Otto; Cafri, Guy; Paxton, Elizabeth; Sedrakyan, Art; Graves, Stephen
2014-12-17
Differences in survivorship of non-posterior-stabilized compared with posterior-stabilized knee designs carry substantial economic consequences, especially with limited health-care resources. However, these comparisons have often been made between relatively small groups of patients, often with short-term follow-up, with only small differences demonstrated between the groups. The goal of this study is to compare the outcomes of non-posterior-stabilized and posterior-stabilized total knee arthroplasties with use of a unique collaboration of multiple established knee arthroplasty registries. A distributed health data network was developed by the International Consortium of Orthopaedic Registries and was used in this study to reduce barriers to participation (such as security, propriety, legal, and privacy issues) compared with a centralized data warehouse approach. The study included only replacements in osteoarthritis patients who underwent total knee procedures involving fixed-bearing devices from 2001 to 2010. The outcome of interest was time to first revision. On average, not resurfacing showed a more harmful effect than resurfacing did when posterior-stabilized and non-posterior-stabilized knee replacements were compared, while the risk of revision for posterior-stabilized compared with non-posterior-stabilized knees was highest in year zero to one, followed by year one to two, years eight through ten, and years two through eight. Posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did when the patella was not resurfaced. This difference was most pronounced in the first two years (year zero to one: hazard ratio [HR] = 2.15, 95% confidence interval [CI] = 1.56 to 2.95, p < 0.001; year one to two: HR = 1.61, 95% CI = 1.48 to 1.75, p < 0.001). When the patella was resurfaced, posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did. This was again most pronounced in the first two years (year zero to one: HR = 1.75, 95% CI = 1.27 to 2.42, p = 0.001; year one to two: HR = 1.31, 95% CI = 1.19 to 1.45, p < 0.001). There was a reduced risk of revision with a patient age of more than sixty-five years (HR = 0.57, 95% CI = 0.55 to 0.60, p < 0.001). We found that fixed non-posterior-stabilized total knee arthroplasty performed better with or without patellar resurfacing than did fixed posterior-stabilized total knee arthroplasty. This effect was most pronounced in the first two years. The risk of revision for posterior-stabilized total knee arthroplasties was reduced with patellar resurfacing. Also, a patient age of more than sixty-five years and female gender reduced the risk of revision. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Posterior corneal topographic changes after partial flap during laser in situ keratomileusis
Sharma, N; Rani, A; Balasubramanya, R; Vajpayee, R B; Pandey, R M
2003-01-01
Aim: To study the posterior corneal topographic changes in eyes with partial flaps during laser assisted in situ keratomileusis (LASIK). Methods: Case records of 16 patients, who had partial flap in one eye during LASIK (group 1) and uncomplicated surgery in the other eye (group 2), were studied. Following occurrence of partial flap intraoperatively, laser ablation was abandoned in all the eyes. A 160/180 μm flap was attempted during the initial procedure using the Hansatome microkeratome (Bausch & Lomb Surgicals, Munich, Germany). LASIK surgery in all cases was performed using a 180 μm plate, at the mean interval of 4.16 (SD 1.5) months following the initial procedure. None of the eyes had intraoperative complication during LASIK. Relative posterior corneal surface elevation above the best fit sphere (BFS) before the initial procedure, before, and after LASIK were compared using the Orbscan slit scanning corneal topography/pachymetry system. Results: Posterior corneal elevation was comparable in the two groups, both preoperatively (group 1; 16.4 (4.8) μm, group 2; 16.1 (4.8) μm) and after final surgery (group 1; 57.2 (15.6) μm, group 2; 54.3 (13.1) μm). In group 1 after occurrence of partial flap, the posterior corneal elevation was 16.9 (4.4) μm, and this increase was not significant statistically (p=0.4). On multiple linear regression analysis, residual bed thickness (p<0.001) was independently the significant determinant of final posterior corneal elevation in both groups. Conclusion: The inadvertent occurrence of partial flap during LASIK procedure does not contribute to the increase in posterior corneal elevation. PMID:12543743
[Modified two-stage surgery for total auriculoplasty with autogenous rib cartilage].
Zhang, Zheng-wen; Kang, Shen-song; Xie, Feng; Ma, Teng-xiao; Li, Lei; Zhai, Hong-feng; Chou, Hai-yan; Li, Hao; Zhong, Ai-mei; Zhang, Dong-yi
2011-09-01
To introduce a modified surgery for total auriculoplasty and the experience in one hundred and forty-six cases (155 ears). The procedure was a two-stage operation. The first stage involved fabrication and grafting of a costal cartilage framework. A U-shaped skin incision was made on the posterior edge of the lobule and the remnant ear cartilage was removed completely. The area for the insertion of the cartilage framework was undermined. Skin flaps were sutured after insertion of the cartilage framework. The second-stage surgery was usually performed six months after the first-stage operation. The reconstructed auricle was elevated, and a costal cartilage block was fixed to the posterior part of the auricle. A temporoparietal fascia flap was then used to cover the costal cartilage block. Finally, the posterior aspect of the projected auricle was covered with a spit-thickness skin graft. The incisions healed in one hundred and forty-one patients (150 ears) after the first stage operation. Partial necrosis of the postauricular flap was observed in five cases (5 ears) after the first stage operation, but no exposure or absorption of the cartilage took place. The skin grafts survived in one hundred and thirty-nine cases (147 ears) after the second-stage surgery. Partial necrosis of the skin graft was observed in seven cases (8 ears), but healed after one-week of dressing changes. Ninety-four cases (97 ears) were followed up, but fifty-two cases (58 ears) were lost to follow up. The follow-up at six months to two years showed satisfactory contour and projection of the constructed ears. This two-stage surgery is simple and ideal for auricloplasty with few complications.
Bayes factors for testing inequality constrained hypotheses: Issues with prior specification.
Mulder, Joris
2014-02-01
Several issues are discussed when testing inequality constrained hypotheses using a Bayesian approach. First, the complexity (or size) of the inequality constrained parameter spaces can be ignored. This is the case when using the posterior probability that the inequality constraints of a hypothesis hold, Bayes factors based on non-informative improper priors, and partial Bayes factors based on posterior priors. Second, the Bayes factor may not be invariant for linear one-to-one transformations of the data. This can be observed when using balanced priors which are centred on the boundary of the constrained parameter space with a diagonal covariance structure. Third, the information paradox can be observed. When testing inequality constrained hypotheses, the information paradox occurs when the Bayes factor of an inequality constrained hypothesis against its complement converges to a constant as the evidence for the first hypothesis accumulates while keeping the sample size fixed. This paradox occurs when using Zellner's g prior as a result of too much prior shrinkage. Therefore, two new methods are proposed that avoid these issues. First, partial Bayes factors are proposed based on transformed minimal training samples. These training samples result in posterior priors that are centred on the boundary of the constrained parameter space with the same covariance structure as in the sample. Second, a g prior approach is proposed by letting g go to infinity. This is possible because the Jeffreys-Lindley paradox is not an issue when testing inequality constrained hypotheses. A simulation study indicated that the Bayes factor based on this g prior approach converges fastest to the true inequality constrained hypothesis. © 2013 The British Psychological Society.
NASA Astrophysics Data System (ADS)
Zaharia, C.; Gabor, A.; Sinescu, C.; Topala, F. I.; Negrutiu, M. L.; Levai, C. M.; Duma, V. F.; Bradu, A.; Podoleanu, A. Gh.
2016-03-01
Introduction. Dental ceramics show better biocompatibility and aesthetic properties in dental constructs with regard to metals. However, they also have an insufficient mechanical stability, as well as low resistance limits due to their fragility. Taking into account these aspects, glass infiltrated with ceramic materials such as alumina (i.e., zirconiareinforced ceramics) is being nowadays considered a better material for full fixed partial prostheses (FPPs) than ceramics: the former has a higher mechanical resistance, which makes it more appropriate for restoration areas, where there is an increased mechanical stress. The interest for zirconia is growing due both to its resistance and to the possibility to develop such prostheses using the CAD/CAM technology. Materials and methods. 24 all ceramic FPPs created with CAD/CAM technology were used. The models were scanned with Zeno Wieland Scanner, a one touch scanning machine which requires between 45-60 s for a full model scan. The scanner provides 3 axis-architecture and automatic data processing. The zirconia infrastructures resulted from milling zirconia green disks in Wieland units, followed by the deposition of ceramic masses and then by burning procedures. All the samples were assessed with a Time Domain Optical Coherence Tomography (TD-OCT) system working at a wavelenght of 1300 nm. Using OCT investigations, material defects were detected in the areas of maximal tension, i.e. the connectors, the oclusal, and the cervical areas. These samples with defects in the above areas have not been considered for the study further on. Finally, the samples were loaded in a MultiTest 5 i Mecmesin system and tested until fracture occurred. The MultiTest 5-i creates tensile and compression forces of up to 5 kN. Results and discussions. All the test samples survived a dynamic load of 1.2 x 107 cycles and a thermal cycle mixer simulator version; signs of failure in terms of fracture lines were observed in all samples. The average value of the force necessary to break the FPPs obtained from the tests is 1750 N. Conclusions. Conventional metal-ceramic fixed partial dentures are still considered the standard for edentulous spaces in the posterior region. Therefore, the resistance of metal-ceramic fixed partial dentures has served in this study as a guide for new ceramics tests. All the values from this study conducted in FPP with zirconia frames were much lower than the values reported for metal ceramic fixed partial dentures (i.e., 2500-3000 N), but higher that 1000 N, which is considered the lowest resistance point to be utilized in the rear region of the oral cavity.
Dong, Ling-Dai; Bing, Chang-Jian; Li, Jian-Lin; Cai, Yue
2017-04-25
To discuss the advantages of the arthroscopic treatment for complex tears of the medial meniscus posterior horn by creating a tunnel passageway through the intercondylar fossa. All 127 patients including 24 males and 103 females with complex tears at the medial meniscus posterior horn were reviewed. The age of all patients ranged from 45 to 78 years old, with an average of 67 years old. All 127 patients were treated with partial meniscectomy, in which 112 patients were treated with partial meniscectomy smoothly with three incisions (anterior medial incision, anterior lateral incision, high anterior lateral incision), and 15 patients were treated with four incisions (anterior medial incision, anterior lateral incision, high anterior lateral incision, posterior medial incision). Four aspects were estimated:whether the meniscus posterior horns could be observed totally and conveniently, whether tools could be pushed to target area conveniently, the damage of adjacent cartilages, operation time(the operation time of partial meniscectomy). Posterior horns of all patients were totally and conveniently observed, tools were conveniently pushed to the target area in all cases, and all the cases had no iatrogenic injuries at adjacent cartilages. The operation time of partial meniscectomy at posterior horns with three incisions ranged from 5 to 10 minutes, and it ranged from 10 to 30 minutes with four incisions. It is very convenient and fast of the arthroscopy to treat complex tears of the medial meniscus posterior horn by creating a tunnel through the intercondylor fossa. Iatrogenic injuries of the adjacent cartilages were prevented to the greatest extent.
Gonzalo, Esther; Suárez, María J; Serrano, Benjamin; Lozano, José F L
2009-01-01
The purpose of this study was to compare two measurement methods for the external marginal fit of zirconia posterior fixed partial dentures (FPDs) fabricated using computer-aided design/manufacturing technology and metal-ceramic posterior FPDs fabricated using the conventional lost-wax technique. The null hypothesis was that there would be no differences between the measurement methods. Forty standardized steel specimens were prepared to receive posterior three-unit FPDs. Specimens were divided into four groups (n = 10): (1) metal-ceramic, (2) Procera Bridge Zirconia, (3) Lava AllCeramic System, and (4) Vita In-Ceram YZ 2000. All FPDs were luted with glass-ionomer cement (Ketac Cem EasyMix, 3M ESPE). Two measurement methods were used to analyze marginal fit: an image analysis (IA) program and a scanning electron microscope (SEM) (JEOL JSM-6400) with magnifications of 340 and 31,000, respectively. Marginal fit was measured at the same point on each abutment. Significant interaction was observed between measurement method and material (P = .0019). Therefore, the measurement method is not independent of the restoration material. Differences among groups were observed for IA (P = .0001) and SEM (P = .0013). Significant differences were observed for the Procera (P = .0050) and metal-ceramic (P = .0039) specimen groups when both measurement methods were evaluated separately. Accuracy of fit achieved by the four groups analyzed was within the range of clinical acceptance, yielding Procera Bridge Zirconia to have the best marginal fit using both measurement methods.
Dissolution of cement, root caries, fracture, and retrofit of post and cores.
Rosen, H
1998-10-01
Fixed partial denture abutments severely damaged by dental caries or fracture present a challenge to the dentist. The fixed partial denture may need to be removed for endodontic treatment with post and core fabrication. Frequently, the existing fixed partial denture can be recycled as a provisional restoration. Retrofitting the post and core greatly improves the stabilization of the interim as well as the remake of the definitive fixed partial denture. This article describes a chair side procedure for retrofitting posts and cores and, at the same appointment, converting the original fixed partial denture to an effective provisional restoration.
Marshall-Webb, Matthew; Peters, Micah D J; Bright, Tim; Watson, David I
2018-05-01
The objective of this review is to determine the relative effectiveness of Nissen fundoplication compared to anterior and posterior partial fundoplication in controlling the symptoms of gastro-esophageal reflux disease and reducing their side effect profile in adults.The specific questions posed by this review are: what is the effectiveness of Nissen fundoplication in comparison to anterior partial fundoplication (90 degree, 120 degree and 180 degree) and posterior 270 degree fundoplication in terms of symptom control of gastro-esophageal reflux disease, and what are the side effects of these surgical interventions?
Walker, Peter S; Yildirim, Gokce; Sussman-Fort, Jon; Roth, Jonathan; White, Brian; Klein, Gregg R
2007-08-01
Maximum flexion-or impingement angle-is defined as the angle of flexion when the posterior femoral cortex impacts the posterior edge of the tibial insert. We examined the effects of femoral component placement on the femur, the slope angle of the tibial component, the location of the femoral-tibial contact point, and the amount of internal or external rotation. Posterior and proximal femoral placement, a more posterior femoral-tibial contact point, and a more tibial slope all increased maximum flexion, whereas rotation reduced it. A mobile-bearing knee gave results similar to those of the fixed-bearing knee, but there was no loss of flexion in internal or external rotation if the mobile bearing moved with the femur. In the absence of negative factors, a flexion angle of 150 degrees can be reached before impingement.
Lopez-Suarez, Carlos; Gonzalo, Esther; Pelaez, Jesus; Serrano, Benjamin; Suarez, Maria J
2016-01-01
The aim of this study was to investigate and compare the marginal fit of posterior fixed dental prostheses (FDPs) made of monolithic and veneered computer-aided design/computer-assisted manufacture (CAD/CAM) zirconia ceramic with metal-ceramic posterior FDPs. Thirty standardized steel dies were prepared to receive posterior three-unit FDPs. Specimens were randomly divided into three groups (n = 10): (1) metal-ceramic (control group), (2) veneered zirconia, and (3) monolithic zirconia. All FDPs were cemented using a glass-ionomer cement. The specimens were subjected to thermal cycling (5°C to 55°C). A scanning electron microscope (SEM) with a magnification of ×500 was used for measurements. The data were statistically analyzed using one-way analysis of variance and paired t test. Both zirconia groups showed similar vertical marginal discrepancies, and no significant differences (P = .661) in marginal adaptation were observed among the groups. No differences were observed in either group in marginal discrepancies between surfaces or abutments. Monolithic zirconia posterior FDPs exhibit similar vertical marginal discrepancies to veneered zirconia posterior FDPs. No influence of localization measurements was observed.
Siebold, R; Louisia, S; Canty, J; Bartlett, R J
2007-02-01
Posterior tibial translation in total knee replacement (TKR) could be one major factor for PE wear, delamination and loosening of the tibial component due to increased shear forces and component-to-bone interface stress. The aim of this study was to assess the posterior stability of two different designs of posterior cruciate ligament (PCL) substituting TKR. In this non-randomised consecutive study 43 patients underwent TKR for primary osteoarthritis. Twenty-six patients in group FB received a deep-dished fixed-bearing Duracon TKR (Howmedica, Rutherford, NJ, USA) and 17 patients in group MB a deep-dished rotating mobile-bearing Duracon TKR. In both groups the PCL was resected. All patients had pre- and postoperative kneeling stress radiographs and were clinically evaluated with the Knee Society Score. Posterior tibial translation was measured by tracing a line along the posterior tibial cortex in relationship to the posterior edge of Blumensaat's line. The average follow-up was 13 months for group FB and 11 months for group MB. Both groups demonstrated a statistical significant increase of the mean posterior tibial translation on kneeling stress X-ray of 4.1 mm (group FB) (P < 0.001) and of 6.6 mm (group MB) (P < 0.001) compared to pre-operative. Group MB showed a significant higher posterior draw (P < 0.008). Clinical assessment using the Knee Society Score showed comparable short-term results. The deep-dished fixed-bearing TKR as well as the deep-dished rotating mobile-bearing TKR demonstrated significant posterior tibial translation on kneeling stress X-ray. It remains to be determined what amount of joint play is optimal for clinical function and to minimise shear forces and PE wear. Moreover the amount of posterior tibial translation was significantly higher with the mobile-bearing insert, which could be directly related to the asymmetric rotational mobility of the tibial insert. A long-term follow-up is necessary to investigate whether our findings correlate with the survival-rate of these specific implants.
Accuracy of six elastic impression materials used for complete-arch fixed partial dentures.
Stauffer, J P; Meyer, J M; Nally, J N
1976-04-01
1. The accuracy of four types of impression materials used to make a complete-arch fixed partial denture was evaluated by visual comparison and indirect measurement methods. 2. None of the tested materials allows safe finishing of a complete-arch fixed partial denture on a cast poured from one single master impression. 3. All of the tested materials can be used for impressions for a complete-arch fixed partial denture provided it is not finished on one single cast. Errors can be avoided by making a new impression with the fitted castings in place. Assembly and soldering should be done on the second cast. 4. In making the master fixed partial denture for this study, inaccurate soldering was a problem that was overcome with the use of epoxy glue. Hence, soldering seems to be a major source of inaccuracy for every fixed partial denture.
Dundar, Mine; Gungor, M Ali; Cal, Ebru
2003-04-01
Esthetics is a major concern during restoration of anterior partial edentulous areas. All-ceramic fixed partial dentures may provide better esthetics and biocompatibility in the restoration of anterior teeth. This clinic report describes a multidisciplinary approach and treatment procedures with an IPS Empress 2 fixed partial denture to restore missing anterior teeth.
Redfern, John C; Thordarson, David B
2008-03-01
Fixed equinovarus deformities can be challenging to treat especially in medically debilitated patients. The purpose of this study was to evaluate Achilles lengthening with posterior tibial tenotomy and immediate weightbearing in this difficult group of patients. Thirteen extremities in 10 patients underwent Achilles lengthening and posterior tibial tenotomy for fixed equinovarus deformities with significant medical comorbidities. Pre- and postoperative ambulatory status and deformities were noted. Average age at the time of surgery was 65 with an average duration of deformity 6.3 years. The average equinus corrected from 26 degrees to 1.2 degrees and the average varus deformity improved from -8.5 degrees to 2.7 degrees. All patients except one who was wheelchair-bound had a significant improvement in ambulatory status. Achilles lengthening with posterior tibial tenotomy allowed for immediate postoperative weightbearing with improvement in deformity and ambulatory status in this complicated patient group.
[Posterior ceramic bonded partial restorations].
Mainjot, Amélie; Vanheusden, Alain
2006-01-01
Posterior ceramic bonded partial restorations are conservative and esthetic approaches for compromised teeth. Overlays constitute a less invasive alternative for tooth tissues than crown preparations. With inlays and onlays they are also indicated in case of full arch or quadrant rehabilitations including several teeth. This article screens indications and realization of this type of restorations.
The FasT-Fix Repair Technique for Ramp Lesion of the Medial Meniscus.
Li, Wei-Ping; Chen, Zhong; Song, Bin; Yang, Rui; Tan, Weiquan
2015-03-01
This technical note describes a new arthroscopic technique to repair the peripheral attachment lesion of the posterior horn of the medial meniscus. The operation was performed under arthroscopy using a standard anterior portal. A FasT-Fix needle was inserted obliquely close to the tibial plateau and the first implant was inserted into the joint capsule depending on its bending angle underneath the meniscus. The second implant was inserted through 1/3 periphery of the meniscus into the meniscocapsular area. The pre-tied self-sliding knot was tensioned to achieve secure fixation of the posterior meniscal peripheral attachment at the original attachment point. From August 2011 to February 2014, 23 knees were diagnosed as ramp lesion, underwent meniscal repair using FasT-Fix technique. All patients were followed up for average 14 months. The Lysholm score improved from preoperative 64.4±4.52 to postoperative 91.2±4.60. We believe that the FasT-Fix technique via the standard anterior portal can be a more convenient and less traumatic alternative for repair of the peripheral attachment lesion of the posterior horn of the medial meniscus in the anterior cruciate ligament deficient knee.
An unusual cause of cervical kyphosis.
Raj, Mamtha S; Schwab, Joseph H
2017-02-01
Acute fixed cervical kyphosis may be a rare presentation of conversion disorder, psychogenic dystonia, and potentially as a side effect from typical antipsychotic drugs. Haldol has been associated with acute dystonic reactions. In some cases, rigid deformities ensue. We are reporting a case of a fixed cervical kyphosis after the use of Haldol. To present a case of a potential acute dystonic reaction temporally associated with Haldol ingestion leading to fixed cervical kyphosis. This is a case report. A patient diagnosed with bipolar disorder presented to the emergency room several times with severe neck pain and stiffness. The neck appeared fixed in flexion with extensive osteophyte formation over a 3-month period. The patient's condition was resolved by a posterior-anterior-posterior surgical approach. It corrected the patient's cervical curvature from 88° to 5°. Acute dystonic reactions have the potential to apply enough pressure on bone to cause rapid osteophyte formation. Copyright © 2016 Elsevier Inc. All rights reserved.
Zhou, Tuan feng; Wang, Xin zhi; Zhang, Gui rong
2011-02-18
To clinic observation of IPS Empress2 and IPS e.max all ceramic resin bonded fixed partial dentures used in one anterior teeth lost in upper jaw or less than two anterior tooth lost in lower jaw. 22 patients, 26 restorations had been made, which included 16 single-retainer all ceramic resin bonded fixed partial dentures and 10 two-retainers all ceramic resin bonded fixed partial dentures. Secondary caries of the abutments, shade in the margin of the retainers and the integrity of the restorations had been observed at 3 months, 6 months, 1 year, 2 years and 3 years after all ceramic resin bonded fixed partial dentures having been bonded. In the 3 years of clinic observation of the anterior all ceramic resin bonded fixed partial dentures, 1 two-retainers restoration lost bond after it had been made for 3 months, a retainer of one two-retainers restoration was broken after 6 months, but they are still used after modified as one-retainer all ceramic resin bonded fixed partial dentures, 1 two-retainers restoration lost bond two year later, It was integrity and re-bonded again that was still stable. No secondary carries and no shade in margin of the retainers had been found. Their color matches with the nature teeth excellently. The success rate was 88.5%. IPS Empress 2 and IPS e.max all ceramic resin bonded fixed partial dentures should be a good selection in one or two teeth lose in anterior jaws.
1974-08-31
Removable Partial Dentures ..................... 34 XI. Fixed Partial Denture Construction .. ........ 35 l. Construct Master Cast with Removable...Dies . . . 36 2. Construct Patterns for Fixed Partial Dentures .. . ..... 37 3. Spruing and Investing oeu . . . 38 4. Wax Elimination and Casting...42 S. Re3in Jacket Crowns . . ............ 43 9. Temporary Crowns and Fixed Partial Dentures . . 44 10. Post and Core Techniques . . o
Fixed or mobile-bearing total knee arthroplasty
Huang, Chun-Hsiung; Liau, Jiann-Jong; Cheng, Cheng-Kung
2007-01-01
Fixed and mobile-bearing in total knee arthroplasty are still discussed controversially. In this article, biomechanical and clinical aspects in both fixed and mobile-bearing designs were reviewed. In biomechanical aspect, the mobile-bearing design has proved to provide less tibiofemoral contact stresses under tibiofemoral malalignment conditions. It also provides less wear rate in in-vitro simulator test. Patients with posterior stabilized mobile-bearing knees had more axial tibiofemoral rotation than patients with posterior stabilized fixed-bearing knees during gait as well as in a deep knee-bend activity. However, in clinical aspect, the mid-term or long-term survivorship of mobile-bearing knees has no superiority over that of fixed-bearing knees. The theoretical advantages for mobile-bearing design to provide a long-term durability have not been demonstrated by any outcome studies. Finally, the fixed-bearing design with all-polyethylene tibial component is suggested for relatively inactive, elder people. The mobile-bearing design is suggested for younger or higher-demand patients due to the potential for reduced polyethylene wear and more normal kinematics response after joint replacement. For younger surgeon, the fixed-bearing design is suggested due to less demand for surgical technique. For experienced surgeon, one familiar surgical protocol and instrumentation is suggested rather than implant design, either fixed-bearing or mobile-bearing. PMID:17204165
Fixed or mobile-bearing total knee arthroplasty.
Huang, Chun-Hsiung; Liau, Jiann-Jong; Cheng, Cheng-Kung
2007-01-05
Fixed and mobile-bearing in total knee arthroplasty are still discussed controversially. In this article, biomechanical and clinical aspects in both fixed and mobile-bearing designs were reviewed. In biomechanical aspect, the mobile-bearing design has proved to provide less tibiofemoral contact stresses under tibiofemoral malalignment conditions. It also provides less wear rate in in-vitro simulator test. Patients with posterior stabilized mobile-bearing knees had more axial tibiofemoral rotation than patients with posterior stabilized fixed-bearing knees during gait as well as in a deep knee-bend activity. However, in clinical aspect, the mid-term or long-term survivorship of mobile-bearing knees has no superiority over that of fixed-bearing knees. The theoretical advantages for mobile-bearing design to provide a long-term durability have not been demonstrated by any outcome studies. Finally, the fixed-bearing design with all-polyethylene tibial component is suggested for relatively inactive, elder people. The mobile-bearing design is suggested for younger or higher-demand patients due to the potential for reduced polyethylene wear and more normal kinematics response after joint replacement. For younger surgeon, the fixed-bearing design is suggested due to less demand for surgical technique. For experienced surgeon, one familiar surgical protocol and instrumentation is suggested rather than implant design, either fixed-bearing or mobile-bearing.
Nosouhian, Saeid; Davoudi, Amin; Derhami, Mohammad
2015-01-01
This clinical report describes prosthetic rehabilitation of posterior open bite relationship in a patient with several missing teeth and skeletal Class III malocclusion. Primary diagnostic esthetic evaluations were performed by mounting casts in centric relation and estimating lost vertical dimension of occlusion. Exclusive treatments were designated by applying overlay removable partial denture with external attachment systems for higher retentions. PMID:26929544
Nosouhian, Saeid; Davoudi, Amin; Derhami, Mohammad
2015-01-01
This clinical report describes prosthetic rehabilitation of posterior open bite relationship in a patient with several missing teeth and skeletal Class III malocclusion. Primary diagnostic esthetic evaluations were performed by mounting casts in centric relation and estimating lost vertical dimension of occlusion. Exclusive treatments were designated by applying overlay removable partial denture with external attachment systems for higher retentions.
Pommer, Bernhard; Krainhöfner, Martin; Watzek, Georg; Tepper, Gabor; Dintsios, Charalabos-Markos
2012-01-01
The aim of this systematic review was to evaluate the functionality of fixed and removable partial dentures as test interventions in relation to variations in the opposing dentition and their prosthetic restoration. The abstracts identified in the respective databases were screened independently by two investigators. RCTs and uncontrolled studies were considered, provided the patients were included consecutively and the confounding variables were adequately monitored. Seventeen papers were included. The study and publication quality was assessed using a “biometric quality” tool showing an overall poor quality. The reported outcomes, such as survival rates, were in each case obtained from a single study. Two possible trends could be deduced for the endpoint longevity: (a) the first trend in favor of removable partial dentures, compared to fixed partial dentures, with a fully edentulous opposing arch fitted with a removable prosthesis; (b) the second trend in favor of implant-supported partial dentures, compared to conventionally fixed partial dentures, with natural opposing dentition or with a removable partial denture in the opposing arch. No evidence could be generated as to whether, and if so how, variations in the opposing dentition have a bearing on the decision to fit a partially edentulous arch with a fixed or removable partial denture. PMID:23193407
Chhibber, Aditya; Upadhyay, Madhur
2016-11-01
Protraction of mandibular posterior teeth requiring absolute anchorage has always been a challenge, especially when the space is located in the anterior region, since more teeth must be protracted. Traditionally, skeletal anchorage devices have been used for anchorage reinforcement during protraction. However, drawbacks such as requirement of a surgical step, inability to tolerate heavy forces, and patient willingness to undergo such surgical procedures can be limiting factors. Additionally, the mechanics involved can sometimes create undesirable side effects, thereby limiting their application in such situations. This report describes the use of a fixed functional appliance as an anchorage-reinforcement device for en-masse protraction of mandibular posterior teeth into a missing lateral incisor space. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Location of prosthodontic treatment and oral health-related quality of life--an exploratory study.
Sukumar, Smitha; John, Mike T; Schierz, Oliver; Aarabi, Ghazal; Reissmann, Daniel R
2015-01-01
Prosthodontic treatment has a positive effect on oral health-related quality of life (OHRQoL); however, there is a paucity of studies assessing the impact of OHRQoL based on where in the mouth ("location") the treatment is performed. This exploratory study investigated the association of the location (anterior, posterior region) of prosthodontic treatment with magnitude and nature of OHRQoL changes. In this non-randomized prospective clinical study, 190 adult patients (17-83 years) were recruited at baseline and 104 were available for the follow-up analyses. Of those, 50 patients received treatment only in the posterior segment and 54 patients in both anterior and posterior regions. Treatment included conventional fixed partial prostheses, removable prostheses or a combination of both. OHRQoL was assessed with the German language version of the 49-item Oral Health Impact Profile (OHIP) at baseline and the questionnaire was repeated 4-6 weeks post-treatment. Magnitude and effect size of changes in summary and sub-scale scores were calculated and data analyzed. Patients experienced a substantially impaired OHRQoL (mean OHIP score: 32.3 points) at baseline and an improvement in OHRQoL of 6.8 OHIP points following treatment. This study showed a greater improvement in OHRQoL in patients treated in both regions compared to those treated in the posterior region alone, especially in the function and aesthetic domains. This explorative study suggests that OHRQoL improvement is affected by where prosthodontic treatment is performed in the mouth. Greater understanding of qualitative aspects of reconstructive therapies is needed for improved treatment planning and patient consent. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Schwabe, P; Märdian, S; Perka, C; Schaser, K-D
2016-04-01
Reconstruction/stable fixation of the acetabular columns to create an adequate periacetabular requirement for the implantation of a revision cup. Displaced/nondisplaced fractures with involvement of the posterior column. Resulting instability of the cup in an adequate bone stock situation. Periprosthetic acetabulum fractures with inadequate bone stock. Extended periacetabular defects with loss of anchorage options. Isolated periprosthetic fractures of the anterior column. Septic loosening. Dorsal approach. Dislocation of hip. Mechanical testing of inlaying acetabular cup. With unstable cup situation explantation of the cup, fracture fixation of acetabulum with dorsal double plate osteosynthesis along the posterior column. Cup revision. Hip joint reposition. Early mobilization; partial weight bearing for 12 weeks. Thrombosis prophylaxis. Clinical and radiological follow-ups. Periprosthetic acetabular fracture in 17 patients with 9 fractures after primary total hip replacement (THR), 8 after revision THR. Fractures: 12 due to trauma, 5 spontaneously; 7 anterior column fractures, 5 transverse fractures, 4 posterior column fractures, 1 two column fracture after hemiendoprosthesis. 5 type 1 fractures and 12 type 2 fractures. Operatively treated cases (10/17) received 3 reinforcement ring, 2 pedestal cup, 1 standard revision cup, cup-1 cage construct, 1 ventral plate osteosynthesis, 1 dorsal plate osteosynthesis, and 1 dorsal plate osteosynthesis plus cup revision (10-month Harris Hip Score 78 points). Radiological follow-up for 10 patients: consolidation of fractures without dislocation and a fixed acetabular cup. No revision surgeries during follow-up; 2 hip dislocations, 1 transient sciatic nerve palsy.
Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs.
Esquivel-Upshaw, Josephine F; Anusavice, Kenneth J; Young, Henry; Jones, Jack; Gibbs, Charles
2004-01-01
The purpose of this research project was to determine the clinical success rate of a lithia disilicate-based core ceramic for use in posterior fixed partial dentures (FPD) as a function of bite force, cement type, connector height, and connector width. Thirty ceramic FPD core frameworks were prepared using a heat-pressing technique and a lithia disilicate-based core ceramic. The maximum clenching force was measured for each patient prior to tooth preparation. Connector height and width were measured for each FPD. Patients were recalled yearly after cementation for 2 years and evaluated using 11 clinical criteria. All FPDs were examined by two independent clinicians, and rankings from 1 to 4 were made for each criterion (4 = excellent; 1 = unacceptable). Two of the 30 ceramic FPDs fractured within the 2-year evaluation period, representing a 93% success rate. One fracture was associated with a low occlusal force and short connector height (2.9 mm). The other fracture was associated with the greatest occlusal force (1,031 N) and adequate connector height. All criteria were ranked good to excellent during the 2-year recall for all remaining FPDs. The performance of the experimental core ceramic in posterior FPDs was promising, with only a 7% fracture rate after 2 years. Because of the limited sample size, it is not possible to identify the maximum clenching force that is allowable to prevent fracture caused by interocclusal forces.
Yunus, Norsiah; Masood, Mohd; Saub, Roslan; Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Thomason, John Mark
2016-07-01
To assess the oral health-related quality of life (OHRQoL) of patients provided with mandibular implant fixed partial prostheses (IFPP) for rehabilitation of two adjacent missing posterior teeth and complete denture patients provided with mandibular implant-supported overdenture (ISOD). The response to change in OHRQoL with implant prostheses was additionally compared. In this prospective study, 20 IFPP (mean age 47.0; SD 12.9 years) and 28 ISOD (mean age 61.5; SD 9.1 years) patients received 2 mandibular implants. Metal ceramic nonsplinted fixed prostheses were provided in IFPP group, while in ISOD group, the mandibular overdentures were retained by nonsplinted attachments. Patients rated their oral health-related quality of life using OHIP-14 Malaysian version at baseline (T0), 2-3 months (T1) and 1 year (T2) postimplant treatment. Mean OHIP-14 for total and domain scores between groups and intervals was analysed using repeated-measures ANOVA and t-test. Mann-Whitney and Wilcoxon signed-rank tests were used for the comparison of mean score change and effect size, while the association between pre- and post-treatment scores was determined using multivariate linear regression modelling. The total OHIP and domain scores before implant treatment were significantly higher (lower OHRQoL) in IFPP than in ISOD groups, except for physical pain where this domain showed similar impact in both groups. Postimplant scores between groups at T1 and T2 showed no significant difference. The mean score changes at T0-T1 and T0-T2 for total OHIP-14 and domains were significantly greater in IFPP except in the domains of physical pain and disability which showed no difference. Large effect size (ES) was observed for total OHIP-14 in IFPP while moderate in ISOD. Improved OHRQoL was dependent on the treatment group and pretreatment score. Improvement in OHRQoL occurred following both mandibular implant-supported overdentures and implant fixed partial prostheses. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Estimation from incomplete multinomial data. Ph.D. Thesis - Harvard Univ.
NASA Technical Reports Server (NTRS)
Credeur, K. R.
1978-01-01
The vector of multinomial cell probabilities was estimated from incomplete data, incomplete in that it contains partially classified observations. Each such partially classified observation was observed to fall in one of two or more selected categories but was not classified further into a single category. The data were assumed to be incomplete at random. The estimation criterion was minimization of risk for quadratic loss. The estimators were the classical maximum likelihood estimate, the Bayesian posterior mode, and the posterior mean. An approximation was developed for the posterior mean. The Dirichlet, the conjugate prior for the multinomial distribution, was assumed for the prior distribution.
[Finite element analysis of stress changes of posterior spinal pedicle screw infixation].
Yan, Jia-Zhi; Wu, Zhi-Hong; Xu, Ri-Xin; Wang, Xue-Song; Xing, Ze-Jun; Zhao, Yu; Zhang, Jian-Guo; Shen, Jian-Xiong; Wang, Yi-Peng; Qiu, Gui-Xing
2009-01-06
To evaluate the mechanical response of L3-L4 segment after posterior interfixation with a transpedicle screw system. Spiral CT machine was used to conduct continuous parallel scan on the L3-L4 section of a 40-year-old healthy male Chinese. The image data thus obtained were introduced into MIMICS software to reconstruct the 2-D data into volume data and obtain 3-D models of every element.. Pro/3-D model construction software system was used to simulate the 3-D entity of L3-L4 fixed by screw robs through spinal pedicle via posterior approach that was introduced into the finite element software ABAQUS to construct a 3-D finite element model. The stress changes on the vertebrae and screw under the axial pressure of 0.5 mPa was analyzed. Under the evenly distributed pressure the displacement of the L4 model was 0.00125815 mm, with an error of only 0.8167% from the datum displacement. The convergence of the model was good. The stress of the fixed vertebral body, intervertebral disc, and internal fixators changed significantly. The stress concentration zone of the intervertebral disc turned from the posterolateral side to anterolateral side. The stress produced by the fixed vertebral bodies decreased significantly. Obvious stress concentration existed in the upper and lower sides of the base of screw and the fixed screw at the upper vertebral body bore greater stress than the lower vertebral body. Integration of computer aided device and finite element analysis can successfully stimulate the internal fixation of L3-IA visa posterior approach and observe the mechanic changes in the vertebral column more directly.
Shi, Kenrin; Hayashida, Kenji; Umeda, Naoya; Yamamoto, Kengo; Kawai, Hideo
2008-02-01
Femoral component rollback and tibial rotation were evaluated using lateral radiographs taken during passive knee flexion under fluoroscopy in NexGen Legacy Posterior Stabilized Flex (Zimmer, Warsaw, Ind) total knee arthroplasties (TKAs; 30 with mobile insert and 26 with fixed insert). Measured maximal flexion angle demonstrated no significant differences. Femoral component rollback was observed predominantly in TKAs with fixed insert in more than 45 degrees flexion and correlated with maximal flexion angle in each group. Tibial internal rotation was more significant in TKAs with mobile insert in maximal flexion. However, tibial internal rotation from 90 degrees to maximal flexion, which demonstrated correlation with maximal flexion angle in each group, did not show significant difference. The kinematic differences between 2 inserts seemed to have little relevance to the maximal flexion angle.
Laparoscopic Heller Myotomy and Fundoplication: What Is the Evidence?
Rebecchi, Fabrizio; Allaix, Marco E; Schlottmann, Francisco; Patti, Marco G; Morino, Mario
2018-04-01
There is no agreement about the best type of fundoplication to add in patients undergoing laparoscopic Heller myotomy (LHM) for achalasia to reduce the risk of postoperative gastroesophageal reflux. This article reviews the current evidence about the outcomes in achalasia patients undergoing LHM with a partial anterior, a partial posterior, or a total fundoplication. We performed a review of the literature in PubMed/Medline electronic databases, which was evaluated according to the GRADE system. The results of the published randomized controlled trials show with a high level of evidence that the addition of a fundoplication reduces the risk of postoperative abnormal reflux, without impairing the food emptying of the esophagus. LHM with partial fundoplication is considered in most centers worldwide the standard of care for the treatment of patients with achalasia. The current evidence fails to show any significant difference between partial anterior and posterior fundoplication. In the absence of further large randomized controlled trial, the decision of performing an anterior or a posterior wrap is based on the surgeon's experience and preference. The addition of a partial fundoplication to LHM leads to a significantly lower rate of postoperative pathological reflux without impairing the esophageal emptying.
Furuhashi, Hiroki; Togawa, Daisuke; Koyama, Hiroshi; Hoshino, Hironobu; Yasuda, Tatsuya; Matsuyama, Yukihiro
2017-05-01
Several reports have indicated that anterior dislocation of total hip arthroplasty (THA) can be caused by spinal degenerative changes with excessive pelvic retroversion. However, no reports have indicated that posterior dislocation can be caused by fixed pelvic anteversion after corrective spine surgery. We describe a rare case experiencing repeated posterior THA dislocation that occurred at 5 months after corrective spinal long fusion with pelvic fixation. A 64-year-old woman had undergone bilateral THA at 13 years before presenting to our institution. She had been diagnosed with kyphoscoliosis and underwent three subsequent spinal surgeries after the THA. We finally performed spinal corrective long fusion from T5 to ilium with pelvic fixation (with iliac screws). Five months later, she experienced severe hip pain when she tried to stand up from the toilet, and was unable to move, due to posterior THA dislocation. Therefore, we performed closed reduction under sedation, and her left hip was easily reduced. After the reduction, she started to walk with a hip abduction brace. However, she had experienced 5 subsequent dislocations. Based on our findings and previous reports, we have hypothesized that posterior dislocation could be occurred after spinal corrective long fusion with pelvic fixation due to three mechanisms: (1) a change in the THA cup alignment before and after spinal corrective long fusion surgery, (2) decreased and fixed pelvic posterior tilt in the sitting position, or (3) the trunk's forward tilting during standing-up motion after spinopelvic fixation. Spinal long fusion with pelvic fixation could be a risk factor for posterior THA dislocation.
Evaluation of metal-polymeric fixed partial prosthesis using optical coherence tomography
NASA Astrophysics Data System (ADS)
Sinescu, C.; Negrutiu, M. L.; Duma, V. F.; Marcauteanu, C.; Topala, F. I.; Rominu, M.; Bradu, A.; Podoleanu, A. Gh.
2013-11-01
Metal-Polymeric fixed partial prosthesis is the usual prosthetic treatment for many dental patients. However, during the mastication the polymeric component of the prosthesis is fractured and will be lost. This fracture is caused by the material defects or by the fracture lines trapped inside the esthetic components of the prosthesis. This will finally lead to the failure of the prosthetic treatment. Nowadays, there is no method of identification and forecast for the materials defects of the polymeric materials. The aim of this paper is to demonstrate the capability of Optical Coherence Tomography (OCT) as a non-invasive clinical method that can be used for the evaluation of metal-polymeric fixed partial prostheses. Twenty metal-polymeric fixed partial prostheses were used for this study. The esthetic component of the prostheses has been Adoro (Ivoclar). Optical investigations of the metal prostheses have revealed no material defects or fracture lines. All the prostheses were temporary cemented in the oral cavities of the patients for six month. The non-invasive method used for the investigations was OCT working in Time Domain mode at 1300 nm. The evaluations of the prostheses were performed before and after their cementation in the patient mouths. All the imagistic results were performed in 2D and than in 3D, after the reconstruction. The results obtained after the OCT evaluation allowed for the identification of 4 metal-polymeric fixed partial prostheses with material defects immediately after finishing the technological procedures. After 6 month in the oral environment other 3 fixed partial prostheses revealed fracture lines. In conclusion, OCT proved to be a valuable tool for the noninvasive evaluation of the metal-polymeric fixed partial prostheses.
Pérez-Cambrodí, Rafael José; Piñero-Llorens, David Pablo; Ruiz-Fortes, Juan Pedro; Blanes-Mompó, Francisco Javier; Cerviño-Expósito, Alejandro
2014-07-01
We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in order to minimize those symptoms. The UZS should be considered as a possible complication after implantation of posterior chamber phakic intraocular lenses.
Fixed partial dentures investigated by optical coherent tomography
NASA Astrophysics Data System (ADS)
Sinescu, Cosmin; Negrutiu, Meda; Todea, Carmen; Hughes, Mike; Tudorache, Florin; Podoleanu, Adrian G.
2008-02-01
Fixed partial prostheses as integral ceramics, integral polymers, metal ceramics or metal polymers bridges, are mainly used in the frontal part of the dental arch (especially the integral bridges). They have to satisfy high stress requirements as well as esthetic. The masticatory stress may induce fractures of the bridges. These may be triggered by initial materials defects or by alterations of the technological process. The fractures of these bridges lead to functional, esthetic and phonetic disturbances which finally render the prosthetic treatment inefficient. The purpose of this study is to evaluate the capability of en-face optical coherence tomography (OCT) in detection and analysis of possible fractures in several integral fixed partial dentures. The materials used were represented by several fixed partial prostheses, integral ceramics, integral polymers, metal ceramics and metal polymers bridges. In order to discover the defects, scanning was performed from incisal, vestibular, oral and cervical directions material defects such as fractures and pores were investigated using OCT. In conclusion, en-face OCT has proven as a valuable non invasive method to investigate fixed partial prostheses before their insertion in the oral cavity.
The presence and influence of posterior capsule tightness on different shoulder problems.
Duzgun, Irem; Turgut, Elif; Çinar-Medeni, Özge; Kafa, Nihan; Tuna, Zeynep; Elbasan, Bulent; Oskay, Deran
2017-01-01
In the literature it has been shown that posterior capsule flexibility is a precursor to shoulder problems. However, no study thus far has shown the influence of the flexibility of posterior capsule in different shoulder pathologies. This study set about to compare the role of posterior capsule tightness in different shoulder problems. One-hundred-twenty-five patients diagnosed with shoulder subacromial impingement syndrome (n= 52), partial rotator cuff tear (n= 31) or frozen shoulder (n= 42) and 30 asymptomatic peers participated in the study. Horizontal adduction was assessed in side-lying position for posterior capsule tightness. Pain was measured via the visual analogue scale and shoulder range of motion and active total elevation was assessed with goniometer. Hand behind the back (HBB) test was assessed the active internal rotation by measuring the distance between T5 and the thumb. It was found that the affected side of the posterior capsules of the patients with subacromial impingement syndrome (p< 0.001), partial rotator cuff tear (p< 0.001) and frozen shoulder (p< 0.001) was stiffer than their healthy side. There were significant differences among groups in the level of tightness in the posterior capsule between the affected and the healthy sides (p< 0.001). All range of motion of the shoulder including HBB test and the posterior capsule tightness of the affected side are found to be correlated (p< 0.05). This study emphasized that the posterior capsule's susceptibility to tightness is most evident in frozen shoulder among different shoulder problems.
Lorenzo, G R; Gutiérrez Dueñas, J M; Ardela, E; Martín Pinto, F
2011-10-01
Congenital malformations of the chest wall are a heterogeneous group of diseases affecting the costal cartilage, ribs, sternum, scapula and clavicle. The pectus excavatum is characterized by a posterior depression of the sternum. Acastello-Welch technique consists in a partial resection of the costal cartilages adding some bars or plates unilaterally fixed to the sternum in each hemithorax. From October 2008 to March 2011 we evaluated 108 patients with congenital malformations of the chest wall. Forty-seven patients (44%) had a pectus excavatum and 12 were treated with Acastello-Welch technique. There were no intraoperative complications. After a mean follow up of 27 months, correction of the deformity was very satisfactory both objective and subjective for patients. The Welch thoracoplasty modified by Acastello is a good option for the correction of the pectus excavatum associating little morbidity and good esthetic outcomes.
Analysis of bone healing in flail chest injury: do we need to fix both fractures per rib?
Marasco, Silvana; Liew, Susan; Edwards, Elton; Varma, Dinesh; Summerhayes, Robyn
2014-09-01
Surgical rib fixation (SRF) for severe rib fracture injuries is generating increasing interest in the medical literature. It is well documented that poorly healed fractured ribs can lead to chronic pain, disability, and deformity. An unanswered question in SRF for flail chest injury is whether it is sufficient to fix one fracture per rib, on successive ribs, thus converting a flail chest injury into simple fractured ribs, or whether both ends of the floating segment of the chest wall should be fixed. This study aimed to analyze SRF in flail chest injury, assessing 3-month outcomes for nonfixed fractured rib ends in the flail segment. This is a retrospective review (2005-2013) of 60 consecutive patients who underwent SRF for flail chest injury admitted to the Alfred Hospital, Melbourne, Australia. Imaging by three-dimensional computed tomography (3D CT) of the chest at admission was compared with follow-up 3D CT at 3 months after injury. The 3-month CT scans were assessed for degree of healing and presence of residual deformity at the fracture fixation site. Follow-up CT was performed in 52 of the 60 patients. At 3 months after surgery, 86.5% of the patients had at least partial healing with good alignment and adequate fracture stabilization. Hardware failure was noted in five patients (9.6%) and occurred with the absorbable prostheses only. Six patients who had preoperative overlapping or displacement showed no improvement in deformity despite fixing the lateral fractures. Callus formation and bony bridging between adjacent ribs was often noted in the rib fractures not fixed (28 of 52 patients, 54%) This retrospective review of 3D CT chest at 3 months after rib fixation indicates that a philosophy of fixing only one fracture per rib in a flail segment does not avoid deformity and displacement, particularly in posterior rib fractures. Therapeutic study, level V; epidemiologic study, level V.
Minami, Keiichiro; Honbo, Masato; Mori, Yosai; Kataoka, Yasushi; Miyata, Kazunori
2015-11-01
To compare area densitometry analysis using rotating Scheimpflug photography in quantifications of posterior capsule opacification (PCO) and surface light scattering with previous anterior-segment analyzer measurement. Miyata Eye Hospital, Miyazaki, Japan. Prospective observational case series. Scheimpflug images of eyes with foldable intraocular lenses (IOLs) were obtained using rotating and fixed Scheimpflug photography. Area densitometry on the posterior and anterior surfaces was conducted for PCO and surface light scattering analyses, respectively, with an identical area size. Correlation between two measurements was analyzed using linear regression. The study included 105 eyes of 74 patients who received IOLs 1 to 18 years (mean, 4.9 ± 4.5 years) postoperatively. In the PCO analysis on the posterior IOL surface, there was a significant correlation between the two measurements (P < .001, R(2) = 0.60). In the surface light scattering analysis, a significant and higher correlation was obtained (P < .001, R(2) = 0.91) until the fixed Scheimpflug photography exhibited saturation due to intensive scatterings. Area densitometry combined with a rotating Scheimpflug photography was exchangeable to previously established densitometry measurement, and allowed successive evaluation in longer-term observations. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Nicolaisen, Maj H; Bahrami, Golnosh; Schropp, Lars; Isidor, Flemming
2016-01-01
The aim of this randomized clinical study was to compare the 3-year clinical outcome of metal-ceramic fixed dental prostheses (MC-FDPs) and zirconia all-ceramic fixed dental prostheses (AC-FDPs) replacing a posterior tooth. A sample of 34 patients with a missing posterior tooth were randomly chosen to receive either a MC-FDP (n = 17) or an AC-FDP (n = 17). The FDPs were evaluated at baseline and yearly until 3 years after cementation. They were assessed using the California Dental Association assessment system. Periodontal parameters were measured at the abutment teeth, and the contralateral teeth served as control. The statistical unit was the FDP/patient. The survival rates for MC-FDPs and AC-FDPs were 100%. The success rate was 76% and 71% for MC-FDPs and AC-FDPs, respectively. Three technical complications were observed in the MC-FDP group and five in the AC-FDP group, all chipping fractures of the ceramic veneer. Furthermore, one biologic complication in the MC-FDP group (an apical lesion) was observed. No framework fractures occurred. All patients had optimal oral hygiene and showed no bleeding on periodontal probing at any of the recalls. Only minor changes in the periodontal parameters were observed during the 3 years of observation. Three-unit posterior MC-FDPs and AC-FDPs showed similar high survival rates and acceptable success rates after 3 years of function, and ceramic veneer chipping fracture was the most frequent complication for both types of restorations.
Marginal and internal fits of fixed dental prostheses zirconia retainers.
Beuer, Florian; Aggstaller, Hans; Edelhoff, Daniel; Gernet, Wolfgang; Sorensen, John
2009-01-01
CAM (computer-aided manufacturing) and CAD (computer-aided design)/CAM systems facilitate the use of zirconia substructure materials for all-ceramic fixed partial dentures. This in vitro study compared the precision of fit of frameworks milled from semi-sintered zirconia blocks that were designed and machined with two CAD/CAM and one CAM system. Three-unit posterior fixed dental prostheses (FDP) (n=10) were fabricated for standardized dies by: a milling center CAD/CAM system (Etkon), a laboratory CAD/CAM system (Cerec InLab), and a laboratory CAM system (Cercon). After adaptation by a dental technician, the FDP were cemented on definitive dies, embedded and sectioned. The marginal and internal fits were measured under an optical microscope at 50x magnification. A one-way analysis of variance (ANOVA) was used to compare data (alpha=0.05). The mean (S.D.) for the marginal fit and internal fit adaptation were: 29.1 microm (14.0) and 62.7 microm (18.9) for the milling center system, 56.6 microm (19.6) and 73.5 microm (20.6) for the laboratory CAD/CAM system, and 81.4 microm (20.3) and 119.2 microm (37.5) for the laboratory CAM system. One-way ANOVA showed significant differences between systems for marginal fit (P<0.001) and internal fit (P<0.001). All systems showed marginal gaps below 120 microm and were therefore considered clinically acceptable. The CAD/CAM systems were more precise than the CAM system.
Kim, Myoung Soo
2015-12-01
We sought to examine anatomic variations of the atlas and the clinical significance of these variations. We retrospectively reviewed 1029 cervical 3-dimensional (3D) CT images. Cervical 3D CT was performed between November 2011 and August 2014. Arcuate foramina were classified as partial or complete and left and/or right. Occipitalization of the atlas was classified in accordance with criteria specified by Mudaliar et al. Posterior arch defects of the atlas were classified in accordance with criteria specified by Currarino et al. One hundred and eight vertebrae (108/1029, 10.5%) showed an arcuate foramen. Bilateral arcuate foramina were present in 41 of these vertebrae and the remaining 67 arcuate foramina were unilateral (right 31, left 36). Right-side arcuate foramina were partial on 18 sides and complete on 54 sides. Left-side arcuate foramina were partial on 24 sides and complete on 53 sides. One case of atlas assimilation was found. Twelve patients (12/1029, 1.17%) had a defect of the atlantal posterior arch. Nine of these patients (9/1029, 0.87%) had a type A posterior arch defect. We also identified one type B, one type D, and one type E defect. Preoperative diagnosis of occipitalization of the atlas and arcuate foramina using 3D CT is of paramount importance in avoiding neurovascular injury during surgery. It is important to be aware of posterior arch defects of the atlas because they may be misdiagnosed as a fracture.
[Fixed partial denture on implants. Prosthodontic and biomechanical considerations].
del Rio Highsmith, J; Garcia-Lomas, S; Mandinazagoitia, C
1990-01-01
In this issue are analyzed the factors that support the selection of the partial edentulous patients, for the construction of partial fixed prosthesis implantosupported, and the biomechanical considerations that we have to consider in relation to: relation implant-bone, the use of natural teeth, part of the jaw, length of the space, opponent jaw and materials.
Chiu, Grace; Chang, Chris; Roberts, W Eugene
2018-03-01
A 36-year-old woman with good periodontal health sought treatment for a compensated Class II partially edentulous malocclusion associated with a steep mandibular plane (SN-MP, 45°), 9 missing teeth, a 3-mm midline discrepancy, and compromised posterior occlusal function. She had multiple carious lesions, a failing fixed prostheses in the mandibular right quadrant replacing the right first molar, and a severely atrophic edentulous ridge in the area around the mandibular left first and second molars. After restoration of the caries, the mandibular left third molar served as anchorage to correct the mandibular arch crowding. The mandibular left second premolar was retracted with a light force of 2 oz (about 28.3 cN) on the buccal and lingual surfaces to create an implant site between the premolars. Modest lateral root resorption was noted on the distal surface of the mandibular left second premolar after about 7 mm of distal translation in 7 months. Six months later, implants were placed in the mandibular left and right quadrants; the spaces were retained with the fixed appliance for 5 months and a removable retainer for 1 month. Poor cooperation resulted in relapse of the mandibular left second premolar back into the implant site, and it was necessary to reopen the space. When the mandibular left fixture was uncovered, a 3-mm deep osseous defect on the distobuccal surface was found; it was an area of relatively immature bundle bone, because the distal aspect of the space was reopened after the relapse. Subsequent bone grafting resulted in good osseous support of the implant-supported prosthesis. The relatively thin band of attached gingiva on the implant at the mandibular right first molar healed with a recessed contour that was susceptible to food impaction. A free gingival graft restored soft tissue form and function. This severe malocclusion with a discrepancy index value of 28 was treated to an excellent outcome in 38 months of interdisciplinary treatment. The Cast-Radiograph Evaluation score was 13. However, the treatment was complicated by routine relapse and implant osseous support problems. Retreatment of space opening and 2 additional surgeries were required to correct an osseous defect and an inadequate soft tissue contour. Orthodontic treatment is a viable option for creating implant sites, but fixed retention is required until the prosthesis is delivered. Bone augmentation is indicated at the time of implant placement to offset expected bone loss. Complex restorative treatment may result in routine complications that are effectively managed with interdisciplinary care. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Gwak, Heui-Chul; Kim, Chang-Wan; Kim, Jung-Han; Choo, Hye-Jeung; Sagong, Seung-Yeob; Shin, John
2015-05-01
The purpose of this study was to evaluate the extension of delamination and the cuff integrity after arthroscopic repair of delaminated rotator cuff tears. Sixty-five patients with delaminated rotator cuff tears were retrospectively reviewed. The delaminated tears were divided into full-thickness delaminated tears and partial-thickness delaminated tears. To evaluate the medial extension, we calculated the coronal size of the delaminated portion. To evaluate the posterior extension, we checked the tendon involved. Cuff integrity was evaluated by computed tomography arthrography. The mean medial extension in the full-thickness and partial-thickness delaminated tears was 18.1 ± 6.0 mm and 22.7 ± 6.3 mm, respectively (P = .0084). The posterior extension into the supraspinatus and the infraspinatus was 36.9% and 32.3%, respectively, in the full-thickness delaminated tears, and it was 27.7% and 3.1%, respectively, in the partial-thickness delaminated tears (P = .0043). With regard to cuff integrity, 35 cases of anatomic healing, 10 cases of partial healing defects, and 17 cases of retear were detected. Among the patients with retear and partial healing of the defect, all the partially healed defects showed delamination. Three retear patients showed delamination, and 14 retear patients did not show delamination; the difference was statistically significant (P = .0001). The full-thickness delaminated tears showed less medial extension and more posterior extension than the partial-thickness delaminated tears. Delamination did not develop in retear patients, but delamination was common in the patients with partially healed defects. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Drijfhout van Hooff, Cornelis Christiaan; Verhage, Samuel Marinus; Hoogendoorn, Jochem Maarten
2015-06-01
One of the factors contributing to long-term outcome of posterior malleolar fractures is the development of osteoarthritis. Based on biomechanical, cadaveric, and small population studies, fixation of posterior malleolar fracture fragments (PMFFs) is usually performed when fragment size exceeds 25-33%. However, the influence of fragment size on long-term clinical and radiological outcome size remains unclear. A retrospective cohort study of 131 patients treated for an isolated ankle fracture with involvement of the posterior malleolus was performed. Mean follow-up was 6.9 (range, 2.5-15.9) years. Patients were divided into groups depending on size of the fragment, small (<5%, n = 20), medium (5-25%, n = 86), or large (>25%, n = 25), and presence of step-off after operative treatment. We have compared functional outcome measures (AOFAS, AAOS), pain (VAS), and dorsiflexion restriction compared to the contralateral ankle and the incidence of osteoarthritis on X-ray. There were no nonunions, 56% of patients had no radiographic osteoarthritis, VAS was 10 of 100, and median clinical score was 90 of 100. More osteoarthritis occurred in ankle fractures with medium and large PMFFs compared to small fragments (small 16%, medium 48%, large 54%; P = .006). Also when comparing small with medium-sized fragments (P = .02), larger fragment size did not lead to a significantly decreased function (median AOFAS 95 vs 88, P = .16). If the PMFF size was >5%, osteoarthritis occurred more frequently when there was a postoperative step-off ≥1 mm in the tibiotalar joint surface (41% vs 61%, P = .02) (whether the posterior fragment had been fixed or not). In this group, fixing the PMFF did not influence development of osteoarthritis. However, in 42% of the cases with fixation of the fragment a postoperative step-off remained (vs 45% in the group without fixation). Osteoarthritis is 1 component of long-term outcome of malleolar fractures, and the results of this study demonstrate that there was more radiographic osteoarthritis in patients with medium and large posterior fragments than in those with small fragments. Radiographic osteoarthritis also occurred more frequently when postoperative step-off was 1 mm or more, whether the posterior fragment was fixed or not. However, clinical scores were not different for these groups. Level IV, retrospective case series. © The Author(s) 2015.
van den Boom, Lennard GH; Brouwer, Reinoud W; van den Akker-Scheek, Inge; Bulstra, Sjoerd K; van Raaij, Jos JAM
2009-01-01
Background Prosthetic design for the use in primary total knee arthroplasty has evolved into designs that preserve the posterior cruciate ligament (PCL) and those in which the ligament is routinely sacrificed (posterior stabilized). In patients with a functional PCL the decision which design is chosen depends largely on the favour and training of the surgeon. The objective of this study is to determine whether the patient's perceived outcome and speed of recovery differs between a posterior cruciate retaining total knee arthroplasty and a posterior stabilized total knee arthroplasty. Methods/Design A randomized controlled trial will be conducted. Patients who are admitted for primary unilateral TKA due to primary osteoarthrosis are included when the following inclusion criteria are met: non-fixed fixed varus or valgus deformity less than 10 degrees, age between 55 and 85 years, body mass index less than 35 kg/m2 and ASA score (American Society of Anaesthesiologists) I or II. Patients are randomized in 2 groups. Patients in the posterior cruciate retaining group will receive a prosthesis with a posterior cut-out for the posterior cruciate ligament and relatively flat topography. In patients allocated to the posterior stabilized group, in which the posterior cruciate ligament is excised, the design may substitute for this function by an intercondylar tibial prominence that articulates with the femur in flexion. Measurements will take place preoperatively and 6 weeks, 3 months, 6 months and 1 year postoperatively. At all measurement points patient's perceived outcome will be assessed using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Secondary outcome measures are quality of life (SF-36) and physician reported functional status and range of motion as determined with the Knee Society Clinical Rating System (KSS). Discussion In the current practice both posterior cruciate retaining and posterior stabilized designs for total knee arthroplasty are being used. To date no studies have been performed determining whether there is a difference in patient's perceived outcome between the two designs. Additionally, there is a lack of studies determining the speed of recovery in both designs as most studies only determine the final outcome. This randomised controlled study has been designed to determine whether the patient's perceived outcome and speed of recovery differs between a posterior cruciate retaining total knee arthroplasty and a posterior stabilized total knee arthroplasty. Trial Registration The trial is registered in the Netherlands Trial Registry (NTR1673). PMID:19793397
Asymptotic approximations to posterior distributions via conditional moment equations
Yee, J.L.; Johnson, W.O.; Samaniego, F.J.
2002-01-01
We consider asymptotic approximations to joint posterior distributions in situations where the full conditional distributions referred to in Gibbs sampling are asymptotically normal. Our development focuses on problems where data augmentation facilitates simpler calculations, but results hold more generally. Asymptotic mean vectors are obtained as simultaneous solutions to fixed point equations that arise naturally in the development. Asymptotic covariance matrices flow naturally from the work of Arnold & Press (1989) and involve the conditional asymptotic covariance matrices and first derivative matrices for conditional mean functions. When the fixed point equations admit an analytical solution, explicit formulae are subsequently obtained for the covariance structure of the joint limiting distribution, which may shed light on the use of the given statistical model. Two illustrations are given. ?? 2002 Biometrika Trust.
Spinal pedicle subtraction osteotomy for fixed sagittal imbalance patients
Hyun, Seung-Jae; Kim, Yongjung J; Rhim, Seung-Chul
2013-01-01
In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Petersen osteotomy provide the least correction, but can be used at multiple levels with minimal blood loss and a lower operative risk. Pedicle subtraction osteotomies provide nearly 3 times the per-level correction of Ponte/Smith-Petersen osteotomies; however, they carry increased technical demands, longer operative time, and greater blood loss and associated significant morbidity, including neurological injury. The literature focusing on pedicle subtraction osteotomy for fixed sagittal imbalance patients is reviewed. The long-term overall outcomes, surgical tips to reduce the complications and suggestions for their proper application are also provided. PMID:24340276
Ahn, Jin Hwan; Oh, Irvin
2004-09-01
Arthroscopic resection of irreparable bucket-handle tears of the medial meniscus is a commonly performed procedure. Adequate visualization of the posterior horn of the medial meniscus can be a challenging task with the conventional use of the anterior portal. An attempt to resect the posterior horn in a blind fashion may result in iatrogenic damage of the articular cartilage in the posterior compartment, over-resection of a remnant meniscus, or an insufficient resection of the torn fragment. We describe the use of the posteromedial portal for an accurate visualization and resection of the posterior attachment of a bucket-handle tear for arthroscopic partial meniscectomy, as well as detection of other injuries that may be involved in the posteromedial compartment, while avoiding injury to other intra-articular structures during the arthroscopic procedure. We found that the use of the posteromedial portal is a safe and efficient method in removing a bucket-handle tear of the medial meniscus in one piece.
Akoh, Craig C; Dibbern, Kevin; Amendola, Annuziato; Sittapairoj, Tinnart; Anderson, Donald D; Phisitkul, Phinit
2017-10-01
Osteochondral lesions of the tibial plafond (OLTPs) can lead to chronic ankle pain and disability. It is not known how limited ankle motion or joint distraction affects arthroscopic accessibility of these lesions. The purpose of this study was to determine the effects of different fixed flexion angles and distraction on accessibility of the distal tibial articular surface during anterior and posterior arthroscopy. Fourteen below-knee cadaver specimens underwent anterior and posterior ankle arthroscopy using a 30-degree 2.7-mm arthroscopic camera. Intra-articular working space was measured with a precision of 1 mm using sizing rods. The accessible areas at the plafond were marked under direct visualization at varying fixed ankle flexion positions. Arthroscopic accessibilities were normalized as percent area using a surface laser scan. Statistical analyses were performed to assess the relationship between preoperative ankle range of motion, amount of distraction, arthroscopic approach, and arthroscopic plafond visualization. There was significantly greater accessibility during posterior arthroscopy (73.5%) compared with anterior arthroscopy (51.2%) in the neutral ankle position ( P = .007). There was no difference in accessibility for anterior arthroscopy with increasing level of plantarflexion ( P > .05). Increasing dorsiflexion during posterior arthroscopy significantly reduced ankle accessibility ( P = .028). There was a significant increase in accessibility through the anterior and posterior approach with increasing amount of intra-articular working space (parameter estimates ± SE): anterior = 14.2 ± 3.34 ( P < .01) and posterior = 10.6 ± 3.7 ( P < .05). Frequency data showed that the posterior third of the plafond was completely inaccessible in 33% of ankles during anterior arthroscopy. The frequency of inaccessible anterior plafond during posterior arthroscopy was 12%. Intra-articular working space and arthroscopic accessibility were greater during posterior arthroscopy compared with anterior arthroscopy. Improved accessibility of OLTPs may be achieved from posterior arthroscopy. Arthroscopic accessibility was heavily dependent on the amount of intraoperative joint working space achieved and not on ankle position. OLTPs are often encountered in tandem with talar lesions, and safely achieving intra-articular working space through noninvasive distraction greatly improved arthroscopic accessibility.
Kumar, Lalit; Sehgal, Komal
2014-06-01
Implants have been designed to rehabilitate edentulous patients with fixed prosthesis or implant supported overdentures. Implant-supported single crowns and fixed partial dentures have become successful treatment alternatives to removable and fixed partial dentures. However, it is common to have clinical situations which make it impossible to use conventional as well as implant supported fixed partial dentures. The implant supported removable partial dentures can be a treatment modality that offers the multitude of benefits of implant-based therapy-biologic, biomechanical, social, and psychological to such patients. The aim of this article is to present a case report describing the fabrication and advantages of removable partial denture supported by teeth and implants for a patient with long edentulous span. The patient was satisfied with his dentures in terms of function and aesthetics. Regular follow-up visits over a period of three years revealed that the periodontal condition of remaining natural dentition and peri-implant conditions were stable. There was no evidence of excessive residual ridge resorption or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs.
Gonzalo, Esther; Suárez, Maria J; Serrano, Benjamin; Lozano, Jose F L
2009-12-01
Marginal discrepancies of zirconia posterior fixed dental prostheses (FDPs) fabricated using various systems have been assessed to determine the quality of the restorations and facilitate clinical use; however, studies are limited and results are ambiguous because of the sample sizes and measurement methods. The purpose of this in vitro study was to compare changes in marginal fit of posterior fixed dental prostheses of 3 zirconia systems manufactured using CAD/CAM technology and metal ceramic posterior fixed dental protheses fabricated with the conventional lost-wax technique, before and after cementation. Forty standardized master steel dies with 2 abutments simulating first mandibular premolars were fabricated to receive a posterior 3-unit FDP (from first molar to first premolar) and divided into 4 groups (n=10): Lava All-Ceramic System, Procera Bridge Zirconia, VITA In-Ceram 2000 YZ, and metal ceramic (control group). All FDPs were prepared for an internal space of 50 microm. The external marginal gap of the restorations was investigated by measuring 30 points in the middle of the buccal and lingual surfaces; therefore, 60 measurements per abutment were recorded. Measurements were made with an image analysis program on the master steel model before and after conventional cementation with a glass ionomer agent (Ketac Cem Easymix). The data obtained were statistically analyzed using 1-way ANOVA, Duncan's multiple range post hoc test, and Student's paired t test (alpha=.05). No significant differences in the vertical marginal fit before and after cementation were recorded for the analyzed groups. The marginal discrepancy of Procera abutments before and after cementation (9 +/-10 microm and 12 +/-9 microm, respectively) was less than that of the other groups. Significant differences (P=.001) were observed in marginal adaptation between Procera Bridge Zirconia and the other groups. The results of this study showed that cementation did not cause a significant increase in the vertical marginal discrepancies of the FDPs and that an internal space of 50 mum provided a high precision of fit of the restorations. The accuracy of fit achieved for the 3 zirconium oxide groups analyzed was within the range of clinical acceptance, and the discrepancies were lower than in the metal ceramic group. Procera Bridge Zirconia showed the lowest vertical discrepancies.
Gupt, Parikshit; Nagpal, Archana; Samra, Rupandeep Kaur; Verma, Ramit; Kaur, Jasjeet; Abrol, Surbhi
2017-01-01
The purpose of the study was to evaluate the fracture strength of provisional fixed partial dentures made of autopolymerizing polymethylmethacrylate (PMMA) resin using different types of reinforcement materials to determine the best among them. Fifty samples were made (10 samples for each group) with autopolymerizing PMMA resin using reinforcement materials (stainless steel wire: looped and unlooped and glass fiber: loose and unidirectional) as 3-unit posterior bridge. The test specimens were divided into five groups depending on the reinforcing material as Group I, II, III, IV, and V; Group I: PMMA unreinforced (control group), Group II: PMMA reinforced with stainless steel wire (straight ends), Group III: PMMA reinforced with stainless steel wire (looped ends), Group IV: PMMA reinforced with unidirectional glass fibers, and Group V: PMMA reinforced with randomly distributed glass fibers. Universal testing machine was used to evaluate and compare the fracture strength of samples. Comparison of mean ultimate force and ultimate stress was done employing one-way analysis of variance and Tukey's post hoc tests. The highest and lowest mean ultimate force and mean ultimate stress were of Group IV and I, respectively. Tukey's post hoc honestly significant difference multiple comparison for mean ultimate force and stress shows the increase in strength to be statistically significant ( P < 0.05) except for the samples reinforced with randomly distributed glass fibers ( P > 0.05). Unidirectional glass fibers showed the maximum strength, which was comparable to mean values of both stainless steel wire groups. Low cost and easy technique of using stainless steel wire make it the material of choice over the unidirectional glass fiber for reinforcement in nonesthetic areas where high strength is required.
Borba, Márcia; Duan, Yuanyuan; Griggs, Jason A; Cesar, Paulo F; Della Bona, Álvaro
2015-04-01
The effect of the ceramic infrastructure (IS) on the failure behavior and stress distribution of fixed partial dentures (FPDs) was evaluated. Twenty FPDs with a connector cross-section of 16 mm(2) were produced for each IS and veneered with porcelain: (YZ) Vita In-Ceram YZ/Vita VM9 porcelain; (IZ) Vita In-Ceram Zirconia/Vita VM7 porcelain; (AL) Vita In-Ceram AL/Vita VM7 porcelain. Two experimental conditions were evaluated (n = 10). For control specimens, load was applied in the center of the pontic at 0.5 mm/min until failure, using a universal testing machine, in 37°C deionized water. For mechanical cycling (MC) specimens, FPDs were subjected to MC (2 Hz, 140 N, 10(6) cycles) and subsequently tested as described for the control group. For YZ, an extra group of 10 FPDs were built with a connector cross-section of 9 mm(2) and tested until failure. Fractography and FEA were performed. Data were analyzed by ANOVA and Tukey's test (α = 0.05). YZ16 showed the greatest fracture load mean value, followed by YZ16-MC. Specimens from groups YZ9, IZ16, IZ16-MC, AL16 and AL16-MC showed no significant difference for the fracture load. The failure behavior and stress distribution of FPDs was influenced by the type of IS. AL and IZ FPDs showed similar fracture load values but different failure modes and stress distribution. YZ showed the best mechanical behavior and may be considered the material of choice to produce posterior FPDs as it was possible to obtain a good mechanical performance even with a smaller connector dimension (9 mm(2)). Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Kim, Sung-Jae; Kim, Sung-Hwan; Lee, Su-Keon; Seo, Jae-Wan; Chun, Yong-Min
2013-08-21
Few studies of large-to-massive contracted rotator cuff tears have examined the arthroscopic complete repair obtained by a posterior interval slide and whether the clinical outcomes or structural integrity achieved are better than those after partial repair without the posterior interval slide. The study included forty-one patients with large-to-massive contracted rotator cuff tears, not amenable to complete repair with margin convergence alone. The patients underwent either arthroscopic complete repair with a posterior interval slide and side-to-side repair of the interval slide edge (twenty-two patients; Group P) or partial repair with margin convergence (nineteen patients; Group M). The patient assignment was not randomized. The Simple Shoulder Test (SST), American Shoulder and Elbow Surgeons (ASES) score, University of California at Los Angeles (UCLA) shoulder score, and range of motion were used to compare the functional outcomes. Preoperative and six-month postoperative magnetic resonance arthrography (MRA) images were compared within or between groups. At the two-year follow-up evaluation, the SST, ASES score, UCLA score, and range of motion had significantly improved (p < 0.001 for all) in both groups. However, no significant differences were detected between groups. Even though the difference in preoperative tear size on MRA images was not significant, follow-up MRA images identified a retear in twenty patients (91%) in Group P and a significant difference in tear size between groups (p = 0.007). The complete repair group with an aggressive release had no better clinical or structural outcomes compared with the partial repair group with margin convergence alone for large-to-massive contracted rotator cuff tears. In addition, the complete repair group had a 91% retear rate and a greater defect on follow-up MRA images. Even though this study had a relatively short-term follow-up, a complete repair of large-to-massive contracted rotator cuff tears, with an aggressive release such as posterior interval slide, may not have an increased benefit compared with partial repair without posterior interval slide.
Ram, Jagat; Gupta, Nishant; Chaudhary, Manish; Verma, Neelam
2013-01-01
Background: A new emerging complication of trans-scleral fixation of posterior chamber (PC) intraocular lens (IOL) with polypropylene suture is high rates of spontaneous dislocation of the IOL due to disintegration or breakage of suture. Materials: We report a new surgical technique of trans-scleral fixation of posterior chamber intraocular lens (SF PCIOL) with steel suture to eliminate the complication of dislocation of IOL fixed with polypropylene suture in one adult and a child. Results: We successfully achieved stable fixation and good centration of IOL after SF PCIOL with steel suture in these patient having inadequate posterior capsular support. Both eyes achieved best corrected visual acuity 20/40 at 18 months follow-up. Conclusions: Steel suture is a viable option for trans-scleral fixation of posterior chamber intraocular lens. PMID:23619504
Democratic superstring field theory: gauge fixing
NASA Astrophysics Data System (ADS)
Kroyter, Michael
2011-03-01
We show that a partial gauge fixing of the NS sector of the democratic-picture superstring field theory leads to the non-polynomial theory. Moreover, by partially gauge fixing the Ramond sector we obtain a non-polynomial fully RNS theory at pictures 0 and 1/2 . Within the democratic theory and in the partially gauge fixed theory the equations of motion of both sectors are derived from an action. We also discuss a representation of the non-polynomial theory analogous to a manifestly two-dimensional representation of WZW theory and the action of bosonic pure-gauge solutions. We further demonstrate that one can consistently gauge fix the NS sector of the democratic theory at picture number -1. The resulting theory is new. It is a {mathbb{Z}_2} dual of the modified cubic theory. We construct analytical solutions of this theory and show that they possess the desired properties.
Wang, Gaoqi; Zhang, Song; Bian, Cuirong; Kong, Hui
2016-01-01
The purpose of the study was to verify the finite element analysis model of three-unite fixed partial denture with in vitro electronic strain analysis and analyze clinical situation with the verified model. First, strain gauges were attached to the critical areas of a three-unit fixed partial denture. Strain values were measured under 300 N load perpendicular to the occlusal plane. Secondly, a three-dimensional finite element model in accordance with the electronic strain analysis experiment was constructed from the scanning data. And the strain values obtained by finite element analysis and in vitro measurements were compared. Finally, the clinical destruction of the fixed partial denture was evaluated with the verified finite element analysis model. There was a mutual agreement and consistency between the finite element analysis results and experimental data. The finite element analysis revealed that failure will occur in the veneer layer on buccal surface of the connector under occlusal force of 570 N. The results indicate that the electronic strain analysis is an appropriate and cost saving method to verify the finite element model. The veneer layer on buccal surface of the connector is the weakest area in the fixed partial denture. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
AlTaan, S L; Termote, K; Elalfy, M S; Hogan, E; Werkmeister, R; Schmetterer, L; Holland, S; Dua, H S
2016-01-01
Purpose To define optical coherence tomography (OCT) characteristics of type-1, type-2, and mixed big bubbles (BB) seen in deep anterior lamellar keratoplasty. Methods Human sclero-corneal discs were obtained from UK (30) and Canada (16) eye banks. Air was injected into corneal stroma until a BB formed. UK samples were fixed in formalin before scanning with Fourier-domain (FD-OCT). One pair of each type of BB was scanned fresh. All BB obtained from Canada were scanned fresh with time-domain (TD-OCT). For each OCT machine used, type-1 BB from which Descemets membrane (DM) was partially peeled, were also scanned. The morphological characteristics of the scans were studied. Results FD-OCT of the posterior wall of type-1 (Dua's layer (DL) with DM) and type-2 BB (DM alone) both revealed a double-contour hyper-reflective curvilinear image with a hypo-reflective zone in between. The anterior line of type-2 BB was thinner than that seen with type-1 BB. In mixed BB, FD-OCT showed two separate curvilinear images. The anterior image was a single hyper-reflective line (DL), whereas the posterior image, representing the posterior wall of type-2 BB (DM) was made of two hyper-reflective lines with a dark space in between. TD-OCT images were similar with less defined component lines, but the entire extent of the BB could be visualised. Conclusion On OCT examination the DM and DL present distinct features, which can help identify type-1, type-2, and mixed BB. These characteristics will help corneal surgeons interpret intraoperative OCT during lamellar corneal surgery. PMID:27472215
Complete vs partial-thickness tears of the posterior cruciate ligament: MR findings.
Patten, R M; Richardson, M L; Zink-Brody, G; Rolfe, B A
1994-01-01
We sought to define the MRI appearance of both complete and partial-thickness tears of the posterior cruciate ligament (PCL) and to describe patterns of injury and associated MRI findings. Three radiologists retrospectively reviewed MR images and medical records on 32 patients with PCL tears (15 complete, 17 partial) and correlated MRI findings to results of clinical testing and surgery. The PCL had indistinct margins in 27 (84%) of 32 patients and was abnormally thick in 25 (78%) patients. In 31 (97%) patients, the torn PCL showed increased signal intensity on both T1- and T2-weighted pulse sequences. Although there was no statistically significant difference between patients with complete tears and those with partial tears with regard to thickness, margination, and signal intensity of the PCL, MR images in patients with complete tears were more likely to show focal areas of ligamentous discontinuity (10 of 15 cases) (p = 0.01). Associated knee injuries were seen in 21 (66%) patients and were seen more frequently in patients with complete PCL tears (p = 0.015). Bony injury (n = 11, 34%) and tears of the medial collateral ligament (n = 13, 41%) and menisci (n = 10, 31%) were common. No specific pattern of bony injury was found. Posterior cruciate ligament tears can be diagnosed readily by multiplanar MRI using both morphological and signal intensity characteristics. Although differentiation between complete and partial-thickness PCL tears by MRI criteria alone is more problematic, complete tears are more likely to show focal areas of discontinuity and partial tears are more likely to show at least some intact fibers.
Orthodontic treatment for posterior crossbites.
Agostino, Paola; Ugolini, Alessandro; Signori, Alessio; Silvestrini-Biavati, Armando; Harrison, Jayne E; Riley, Philip
2014-08-08
A posterior crossbite occurs when the top back teeth bite inside the bottom back teeth. When it affects one side of the mouth, the lower jaw may have to move to one side to allow the back teeth to meet together. Several treatments have been recommended to correct this problem. Some treatments widen the upper teeth while others are directed at treating the cause of the posterior crossbite (e.g. breathing problems or sucking habits). Most treatments have been used at each stage of dental development. This is an update of a Cochrane review first published in 2001. To assess the effects of orthodontic treatment for posterior crossbites. We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 21 January 2014), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2014, Issue 1), MEDLINE via OVID (1946 to 21 January 2014), and EMBASE via OVID (1980 to 21 January 2014). We searched the US National Institutes of Health Trials Register and the World Health Organization (WHO) Clinical Trials Registry Platform for ongoing trials. We placed no restrictions on the language or date of publication when searching the electronic databases. Randomised controlled trials (RCTs) of orthodontic treatment for posterior crossbites in children and adults. Two review authors, independently and in duplicate, screened the results of the electronic searches, and extracted data and assessed the risk of bias of the included studies. We attempted to contact the first named authors of the included studies for missing data and for clarification. We used risk ratios (RR) and 95% confidence intervals (CIs) to summarise dichotomous (event) data, and mean differences (MD) with 95% CIs to summarise continuous data. We performed meta-analyses using fixed-effect models (we would have used random-effects models if we had included four or more studies in a meta-analysis) when comparisons and outcomes were sufficiently similar. We included 15 studies, of which two were at low risk of bias, seven were at high risk of bias and six were unclear. Fixed appliances with mid-palatal expansionNine studies tested fixed appliances with mid-palatal expansion against each other. No study reported a difference between any type of appliance. Fixed versus removable appliancesFixed quad-helix appliances may be 20% more likely to correct crossbites than removable expansion plates (RR 1.20; 95% CI 1.04 to 1.37; two studies; 96 participants; low-quality evidence).Quad-helix appliances may achieve 1.15 mm more molar expansion than expansion plates (MD 1.15 mm; 95% CI 0.40 to 1.90; two studies; 96 participants; moderate-quality evidence).There was insufficient evidence of a difference in canine expansion or the stability of crossbite correction.Very limited evidence showed that both fixed quad-helix appliances and removable expansion plates were superior to composite onlays in terms of crossbite correction, molar and canine expansion. Other comparisonsVery limited evidence showed that treatments were superior to no treatment, but there was insufficient evidence of a difference between any active treatments. There is a very small body of low- to moderate-quality evidence to suggest that the quad-helix appliance may be more successful than removable expansion plates at correcting posterior crossbites and expanding the inter-molar width for children in the early mixed dentition (aged eight to 10 years). The remaining evidence we found was of very low quality and was insufficient to allow the conclusion that any one intervention is better than another for any of the outcomes in this review.
Li, Mengnai; Collier, Rachel C; Hill, Brian W; Slinkard, Nathaniel; Ly, Thuan V
Trimalleolar ankle fractures are unstable injuries with possible syndesmotic disruption. Recent data have described inherent morbidity associated with screw fixation of the syndesmosis, including the potential for malreduction, hardware irritation, and post-traumatic arthritis. The posterior malleolus is an important soft tissue attachment for the posterior inferior syndesmosis ligament. We hypothesized that fixation of a sizable posterior malleolar (PM) fracture in supination external rotation type IV (SER IV) ankle fractures would act to stabilize the syndesmosis and minimize or eliminate the need for trans-syndesmotic fixation. A retrospective review of trimalleolar ankle fractures surgically treated from October 2006 to April of 2011 was performed. A total of 143 trimalleolar ankle fractures were identified, and 97 were classified as SER IV. Of the 97 patients, 74 (76.3%) had a sizable PM fragment. Syndesmotic fixation was required in 7 of 34 (20%) and 27 of 40 (68%), respectively, when the PM was fixed versus not fixed (p = .0002). When the PM was indirectly reduced using an anterior to posterior screw, 7 of 15 patients (46.7%) required syndesmotic fixation compared with none of 19 patients when the PM fragment was fixated with direct posterior lateral plate fixation (p = .0012). Fixation of the PM fracture in SER IV ankle fractures can restore syndesmotic stability and, thus, lower the rate of syndesmotic fixation. We found that fixation of a sizable PM fragment in SER IV or equivalent injuries through posterolateral plating can eliminate the need for syndesmotic screw fixation. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Removable partial denture on osseointegrated implants and natural teeth.
Chang, Li-Ching; Wang, Jen-Chyan; Tasi, Chi-Cheng
2007-01-01
Implants have been designed to provide edentulous patients with fixed prostheses or overdentures. Recently, implant-supported fixed partial prostheses and single crowns have become successful treatment alternatives to removable and fixed partial dentures. However, few researchers have examined "removable partial dentures on implants and natural teeth". In this article, we report two patients fitted with "removable partial dentures on implants and natural teeth". The patients were satisfied with their dentures in terms of function and aesthetics. Regular follow-up visits revealed that the periodontal and peri-implant conditions were stable. There was no evidence of excessive intrusion or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs. Since the average duration of observation was about 38 months, further follow-up examinations are necessary to determine whether these dentures remain stable long-term.
AlBader, Bader; AlHelal, Abdulaziz; Proussaefs, Periklis; Garbacea, Antonela; Kattadiyil, Mathew T; Lozada, Jaime
Implant-supported fixed complete dentures, often referred to as hybrid prostheses, have been associated with high implant survival rates but also with a high incidence of mechanical prosthetic complications. The most frequent of these complications have been fracture and wear of the veneering material. The proposed design concept incorporates the occlusal surfaces of the posterior teeth as part of a digital milled metal framework by designing the posterior first molars in full contour as part of the framework. The framework can be designed, scanned, and milled from a titanium blank using a milling machine. Acrylic resin teeth can then be placed on the framework by conventional protocol. The metal occlusal surfaces of the titanium-countered molars will be at centric occlusion. It is hypothesized that metal occlusal surfaces in the posterior region may reduce occlusal wear in these types of prostheses. When the proposed design protocol is followed, the connection between the metal frame and the cantilever part of the prosthesis is reinforced, which may lead to fewer fractures of the metal framework.
Han, H S; Kang, S-B; Yoon, K S
2007-11-01
We have examined the results obtained with 72 NexGen legacy posterior stabilised-flex fixed total knee replacements in 47 patients implanted by a single surgeon between March 2003 and September 2004. Aseptic loosening of the femoral component was found in 27 (38%) of the replacements at a mean follow-up of 32 months (30 to 48) and 15 knees (21%) required revision at a mean of 23 months (11 to 45). We compared the radiologically-loose and revised knees with those which had remained well-fixed to identify the factors which had contributed to this high rate of aseptic loosening. Post-operatively, the mean maximum flexion was 136 degrees (110 degrees to 140 degrees) in the loosened group and 125 degrees (95 degrees to 140 degrees) in the well-fixed group (independent t-test, p = 0.022). Squatting, kneeling, or sitting cross-legged could be achieved by 23 (85%) of the loosened knees, but only 22 (49%) of the well-fixed knees (chi-squared test, p = 0.001). The loosened femoral components were found to migrate into a more flexed position, but no migration was detected in the well-fixed group. These implants allowed a high degree of flexion, but showed a marked rate of early loosening of the femoral component, which was associated with weight-bearing in maximum flexion.
[Locked volar plating for complex distal radius fractures: maintaining radial length].
Jeudy, J; Pernin, J; Cronier, P; Talha, A; Massin, P
2007-09-01
Maintaining radial length, likely to be the main challenge in the treatment of complex distal radius fractures, is necessary for complete grip-strength and pro-supination range recovery. In spite of frequent secondary displacements, bridging external-fixation has remained the reference method, either isolated or in association with additional percutaneous pins or volar plating. Also, there seems to be a relation between algodystrophy and the duration of traction applied on the radio-carpal joint. Fixed-angle volar plating offers the advantage of maintaining the reduction until fracture healing, without bridging the joint. In a prospective study, forty-three consecutive fractures of the distal radius with a positivated ulnar variance were treated with open reduction and fixed-angle volar plating. Results were assessed with special attention to the radial length and angulation obtained and maintained throughout treatment, based on repeated measurements of the ulnar variance and radial angulation in the first six months postoperatively. The correction of the ulnar variance was maintained until complete recovery, independently of initial metaphyseal comminution, and of the amount of radial length gained at reduction. Only 3 patients lost more than 1 mm of radial length after reduction. The posterior tilt of the distal radial epiphysis was incompletely reduced in 13 cases, whereas reduction was partially lost in 6 elderly osteoporotic female patients. There was 8 articular malunions, all of them less than 2 mm. Secondary displacements were found to be related to a deficient locking technique. Eight patients developed an algodystropy. The risk factors for algodystrophy were articular malunion, associated posterior pining, and associated lesions of the ipsilateral upper limb. Provided that the locking technique was correct, this type of fixation appeared efficient in maintaining the radial length in complex fractures of the distal radius. The main challenge remains the reduction of displaced articular fractures. Based on these results, it is not possible to conclude that this method is superior to external fixation.
Management of long span partially edentulous maxilla with fixed removable denture prosthesis
Jeyavalan, Mahilan I.; Narasimman, M.; Venkatakrishnan, C. J.; Philip, Jacob M.
2012-01-01
Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis. PMID:23293488
Management of long span partially edentulous maxilla with fixed removable denture prosthesis.
Jeyavalan, Mahilan I; Narasimman, M; Venkatakrishnan, C J; Philip, Jacob M
2012-07-01
Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.
Item Selection and Ability Estimation Procedures for a Mixed-Format Adaptive Test
ERIC Educational Resources Information Center
Ho, Tsung-Han; Dodd, Barbara G.
2012-01-01
In this study we compared five item selection procedures using three ability estimation methods in the context of a mixed-format adaptive test based on the generalized partial credit model. The item selection procedures used were maximum posterior weighted information, maximum expected information, maximum posterior weighted Kullback-Leibler…
Tang, Ming-xing; Zhang, Hong-qi; Wang, Yu-xiang; Guo, Chao-feng; Liu, Jin-yang
2016-02-01
Surgical treatment for spinal tuberculosis includes focal tuberculosis debridement, segmental stability reconstruction, neural decompression and kyphotic deformity correction. For the lesions mainly involved anterior and middle column of the spine, anterior operation of debridement and fusion with internal fixation has been becoming the most frequently used surgical technique for the spinal tuberculosis. However, high risk of structural damage might relate with anterior surgery, such as damage in lungs, heart, kidney, ureter and bowel, and the deformity correction is also limited. Due to the organs are in the front of spine, there are less complications in posterior approach. Spinal pedicle screw passes through the spinal three-column structure, which provides more powerful orthopedic forces compared with the vertebral body screw, and the kyphotic deformity correction effect is better in posterior approach. In this paper, we report a 68-year-old male patient with thoracic tuberculosis who underwent surgical treatment by debridement, interbody fusion and internal fixation via posterior approach only. The patient was placed in prone position under general anesthesia. Posterior midline incision was performed, and the posterior spinal construction was exposed. Then place pedicle screw, and fix one side rod temporarily. Make the side of more bone destruction and larger abscess as lesion debridement side. Resect the unilateral facet joint, and retain contralateral structure integrity. Protect the spinal cord, nerve root. Clear sequestrum, necrotic tissue, abscess of paravertebral and intervertebral space. Specially designed titanium mesh cages or bone blocks were implanted into interbody. Fix both side rods and compress both sides to make the mesh cages and bone blocks tight. Reconstruct posterior column structure with allogeneic bone and autologous bone. Using this technique, the procedures of debridement, spinal cord decompression, deformity correction, bone grafting, and internal fixation can be completed with only one incision and surgical position, and the deformity correction efficiency is higher than anterior surgery. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.
Hepatectomy for metastatic liver tumors complicated with right umbilical portion.
Sakaguchi, Takanori; Suzuki, Shohachi; Morita, Yoshifumi; Oishi, Kosuke; Suzuki, Atsushi; Fukumoto, Kazuhiko; Inaba, Keisuke; Takehara, Yasuo; Baba, Satoshi; Nakamura, Satoshi; Konno, Hiroyuki
2011-01-01
We report the case of a 76-year-old man, presenting with a right umbilical portion (RUP), with two liver metastases of rectal cancer, 2cm and 1 cm tumors in the caudate lobe and anterior segment, respectively. The portal first branch ran to the right posterior segment and the remaining formed a left trunk, thereafter forming RUP. The tumor in the caudate was close to the right posterior segment's Glissonean pedicle. On 3-dimensional CT analysis under tubography via an endoscopic naso-biliary tube, the anatomical patterns of the arteries and bile ducts were complicated. On laparotomy, the gallbladder was located to the left of the round ligament. Right posterior segmentectomy plus partial caudate resection and partial hepatectomy of the anterior segment was performed after skeletonization of the biliovascular structures at the hepatic hilum. Precise examination of the biliovascular structures is needed to safely perform hepatectomy in patients complicated with RUP.
Smith, J A; Deviren, V; Berven, S; Kleinstueck, F; Bradford, D S
2001-10-15
A clinical retrospective study was conducted. To evaluate the clinical and radiographic outcome of reduction followed by trans-sacral interbody fusion for high-grade spondylolisthesis. In situ posterior interbody fusion with fibula allograft has improved the fusion rates for patients with high-grade spondylolisthesis. The use of this technique in conjunction with partial reduction has not been reported. Nine consecutive patients underwent treatment of high-grade (Grade 3 or 4) spondylolisthesis with partial reduction followed by posterior interbody fusion using cortical allograft. The average age at the time of surgery was 27 years (range, 8-51 years), and the average follow-up period was 43 months (range, 24-72 months). Before surgery, eight patients had low back pain, seven patients had radiating leg pain, and five patients had hamstring tightness. The average grade of spondylolisthesis by Meyerding grading was 3.9 (range, 3-5). Charts and radiographs were evaluated, and outcomes were collected by use of the modified SRS outcomes instrument. Radiographic indexes demonstrated significant improvement with partial reduction and fusion. The slip angle, as measured from the inferior endplate of L5, improved from 41.2 degrees (range, 24-82 degrees ) before surgery to 21 degrees (range, 5-40 degrees ) after surgery. All the patients were extremely or somewhat satisfied with surgery. The two patients who underwent this operation without initial instrumentation experienced fractures of their interbody grafts. Both of these patients underwent repair of the pseudarthrosis with placement of trans-sacral pedicle screw instrumentation and subsequent fusion. Partial reduction followed by posterior interbody fusion is an effective technique for the management of high-grade spondylolisthesis in pediatric and adult patient populations, as assessed by radiographic and clinical criteria. Pedicle screw instrumentation with the sacral screws capturing L5 is recommended when this technique is used for the treatment of high-grade spondylolisthesis. According to the clinical and radiographic results from this study, partial reduction and posterior fibula interbody fusion supplemented with pedicle screw instrumentation is an effective technique for select patients with high-grade spondylolisthesis at L5-S1.
Dental erosion caused by gastroesophageal reflux disease: a case report
Cengiz, M İnanç; Saraç, Y Şinasi
2009-01-01
Introduction Chronic regurgitation of gastric acids in patients with gastroesophageal reflux disease may cause dental erosion, which can lead in combination with attrition or bruxism to extensive loss of coronal tooth tissue. Case presentation This clinical report describes treatment of severe tooth wear of a gastroesophageal reflux disease patient who is 54-year-old Turkish male patient. After his medical treatment, severe tooth wear, bruxism and decreased vertical dimensions were determined. The vertical dimension was re-established and maxillary and mandibular anterior and posterior teeth were prepared for metal-ceramic restorations. Metal-ceramic fixed partial dentures were fabricated as full mouth restorations for both maxillary and mandibular arches because of splinting all teeth. And then maxillary stabilization splint was fabricated for his bruxism history. Conclusion Significant loss of coronal tooth structure must taken into consideration. Gastroesophageal reflux disease by itself or in combination with attrition, abrasion or bruxism may be responsible for the loss. An extensive diagnostic evaluation is essential for the medical and dental effects of the problem. PMID:19830044
NASA Astrophysics Data System (ADS)
Iglesias, Marco; Sawlan, Zaid; Scavino, Marco; Tempone, Raúl; Wood, Christopher
2018-07-01
In this work, we present the ensemble-marginalized Kalman filter (EnMKF), a sequential algorithm analogous to our previously proposed approach (Ruggeri et al 2017 Bayesian Anal. 12 407–33, Iglesias et al 2018 Int. J. Heat Mass Transfer 116 417–31), for estimating the state and parameters of linear parabolic partial differential equations in initial-boundary value problems when the boundary data are noisy. We apply EnMKF to infer the thermal properties of building walls and to estimate the corresponding heat flux from real and synthetic data. Compared with a modified ensemble Kalman filter (EnKF) that is not marginalized, EnMKF reduces the bias error, avoids the collapse of the ensemble without needing to add inflation, and converges to the mean field posterior using or less of the ensemble size required by EnKF. According to our results, the marginalization technique in EnMKF is key to performance improvement with smaller ensembles at any fixed time.
Dental erosion caused by gastroesophageal reflux disease: a case report.
Cengiz, Seda; Cengiz, M Inanç; Saraç, Y Sinasi
2009-07-22
Chronic regurgitation of gastric acids in patients with gastroesophageal reflux disease may cause dental erosion, which can lead in combination with attrition or bruxism to extensive loss of coronal tooth tissue. This clinical report describes treatment of severe tooth wear of a gastroesophageal reflux disease patient who is 54-year-old Turkish male patient. After his medical treatment, severe tooth wear, bruxism and decreased vertical dimensions were determined. The vertical dimension was re-established and maxillary and mandibular anterior and posterior teeth were prepared for metal-ceramic restorations. Metal-ceramic fixed partial dentures were fabricated as full mouth restorations for both maxillary and mandibular arches because of splinting all teeth. And then maxillary stabilization splint was fabricated for his bruxism history. Significant loss of coronal tooth structure must taken into consideration. Gastroesophageal reflux disease by itself or in combination with attrition, abrasion or bruxism may be responsible for the loss. An extensive diagnostic evaluation is essential for the medical and dental effects of the problem.
Extremely long posterior communicating artery diagnosed by MR angiography: report of two cases.
Uchino, Akira; Suzuki, Chihiro; Tanaka, Masahiko
2015-07-01
We report two cases of an extremely long left posterior communicating artery (PCoA) diagnosed by magnetic resonance (MR) angiography. The PCoA arose from the normal point of the supraclinoid internal carotid artery and fused with the posterior cerebral artery (PCA) at its posterior ambient segment, forming an extremely long PCoA and extremely long precommunicating segment of the PCA. To our knowledge, this is the first report of such variation. Careful observation of MR angiographic images is important for detecting rare arterial variations. To identify these anomalous arteries on MR angiography, partial maximum-intensity-projection images are useful.
Seitz, Andreas Martin; Lubomierski, Anja; Friemert, Benedikt; Ignatius, Anita; Dürselen, Lutz
2012-06-01
We examined the influence of partial meniscectomy of 10 mm width on 10 human cadaveric knee joints, as it is performed during the treatment of radial tears in the posterior horn of the medial meniscus, on maximum contact pressure, contact area (CA), and meniscal hoop strain in the lateral and medial knee compartments. In case of 0° and 30° flexion angle, 20% and 50% partial meniscectomy did not influence maximum contact pressure and area. Only in case of 60° knee flexion, 50% partial resection increased medial maximum contact pressure and decreased the medial CA statistically significant. However, 100% partial resection increased maximum contact pressure and decreased CA significantly in the meniscectomized medial knee compartment in all tested knee positions. No significant differences were noted for meniscal hoop strain. From a biomechanical point of view, our in vitro study suggests that the medial joint compartment is not in danger of accelerated cartilage degeneration up to a resection limit of 20% meniscal depth and 10 mm width. Contact mechanics are likely to be more sensitive to partial meniscectomy at higher flexion angles, which has to be further investigated. Copyright © 2011 Orthopaedic Research Society.
Triceps tendon tear in a middle-aged weightlifter.
Molloy, Joseph M; Aberle, Curtis J; Escobar, Eduardo
2013-11-01
The patient was a 47-year-old man who was evaluated by a physical therapist for a chief complaint of posterior right elbow pain. The patient routinely participated in weightlifting activities and reported a sudden onset of triceps weakness and posterior elbow pain while performing clap push-ups 3 days prior. A physician assistant ordered radiographs, which were initially interpreted as normal, and routine magnetic resonance imaging for the right elbow. Following examination by a physical therapist, due to concern for a triceps tendon tear, the previously ordered magnetic resonance imaging was expedited, which revealed a partial triceps tendon tear with partial tendon retraction medially.
Biomechanical considerations on tooth-implant supported fixed partial dentures
Calvani, Pasquale; Hirayama, Hiroshi
2012-01-01
This article discusses the connection of teeth to implants, in order to restore partial edentulism. The main problem arising from this connection is tooth intrusion, which can occur in up to 7.3% of the cases. The justification of this complication is being attempted through the perspective of biomechanics of the involved anatomical structures, that is, the periodontal ligament and the bone, as well as that of the teeth- and implant-supported fixed partial dentures. PMID:23255882
Yamasaki, Y; Kuwatsuru, R; Tsukiyama, Y; Oki, K; Koyano, K
2016-08-01
We aimed to investigate mastication predominance in healthy dentate individuals and patients with unilateral posterior missing teeth using objective and subjective methods. The sample comprised 50 healthy dentate individuals (healthy dentate group) and 30 patients with unilateral posterior missing teeth (partially edentulous group). Subjects were asked to freely chew three kinds of test foods (peanuts, beef jerky and chewing gum). Electromyographic activity of the bilateral masseter muscles was recorded. The chewing side (right side or left side) was judged by the level of root mean square electromyographic amplitude. Mastication predominance was then objectively assessed using the mastication predominant score and the mastication predominant index. Self-awareness of mastication predominance was evaluated using a modified visual analogue scale. Mastication predominance scores of the healthy dentate and partially edentulous groups for each test food were analysed. There was a significant difference in the distribution of the mastication predominant index between the two groups (P < 0·05). The mastication predominant score was weakly correlated with self-awareness of mastication predominance in the healthy dentate group, whereas strong correlation was observed in the partially edentulous group (P < 0·05). The results suggest that the individuals with missing unilateral posterior teeth exhibited greater mastication predominance and were more aware of mastication predominance than healthy dentate individuals. Our findings suggest that an objective evaluation of mastication predominance is more precise than a subjective method. © 2016 John Wiley & Sons Ltd.
Fixed point theorems for generalized contractions in ordered metric spaces
NASA Astrophysics Data System (ADS)
O'Regan, Donal; Petrusel, Adrian
2008-05-01
The purpose of this paper is to present some fixed point results for self-generalized contractions in ordered metric spaces. Our results generalize and extend some recent results of A.C.M. Ran, M.C. Reurings [A.C.M. Ran, MEC. Reurings, A fixed point theorem in partially ordered sets and some applications to matrix equations, Proc. Amer. Math. Soc. 132 (2004) 1435-1443], J.J. Nieto, R. Rodríguez-López [J.J. Nieto, R. Rodríguez-López, Contractive mapping theorems in partially ordered sets and applications to ordinary differential equations, Order 22 (2005) 223-239; J.J. Nieto, R. Rodríguez-López, Existence and uniqueness of fixed points in partially ordered sets and applications to ordinary differential equations, Acta Math. Sin. (Engl. Ser.) 23 (2007) 2205-2212], J.J. Nieto, R.L. Pouso, R. Rodríguez-López [J.J. Nieto, R.L. Pouso, R. Rodríguez-López, Fixed point theorem theorems in ordered abstract sets, Proc. Amer. Math. Soc. 135 (2007) 2505-2517], A. Petrusel, I.A. Rus [A. Petrusel, I.A. Rus, Fixed point theorems in ordered L-spaces, Proc. Amer. Math. Soc. 134 (2006) 411-418] and R.P. Agarwal, M.A. El-Gebeily, D. O'Regan [R.P. Agarwal, M.A. El-Gebeily, D. O'Regan, Generalized contractions in partially ordered metric spaces, Appl. Anal., in press]. As applications, existence and uniqueness results for Fredholm and Volterra type integral equations are given.
Zhang, Xi-An; Qi, Song-Tao; Fan, Jun; Huang, Guang-Long; Peng, Jun-Xiang
2014-08-01
The aim of this study was to describe the similarity of configuration between the arachnoid complex in the posterior half of the incisural space and the Liliequist membrane. Microsurgical dissection and anatomical observation were performed in 20 formalin-fixed adult cadaver heads. The origin, distribution, and configuration of the arachnoid membranes and their relationships with the vascular structures in the posterior half of the incisural space were examined. The posterior perimesencephalic membrane and the cerebellar precentral membrane have a common origin at the tentorial edge and form an arachnoid complex strikingly resembling an inverted Liliequist membrane. Asymmetry between sides is not uncommon. If the cerebellar precentral membrane is hypoplastic on one side or both, the well-developed quadrigeminal membrane plays a prominent part in partitioning the subarachnoid space in the posterior half of the incisural space. The arachnoid complex in the posterior half of the incisural space can be regarded as an inverted Liliequist membrane. This concept can help neurosurgeons to gain better understanding of the surgical anatomy at the level of the tentorial incisura.
Prosthetic restoration in the single-tooth gap: patient preferences and analysis of the WTP index.
Augusti, Davide; Augusti, Gabriele; Re, Dino
2014-11-01
The objective of this study was to evaluate the preference of a patients' population, according to the index of willingness to pay (WTP), against two treatments to restore a single-tooth gap: the implant-supported crown (ISC) and the 3-unit fixed partial denture prosthesis (FPDP) on natural teeth. Willingness to pay values were recorded on 107 subjects by asking the WTP from a starting bid of €2000 modifiable through monetary increases or decreases (€100). Data were collected through an individually delivered questionnaire. The characteristics of the population and choices made, the median values and WTP associations with socio-demographic parameters (Mann-Whitney and Kruskal-Wallis tests), correlations between variables (chi-square test in contingency tables) and significant parameters for predicting WTP values obtained in a multiple linear regression model were revealed. The 64% of patients expressed a preference for ISC, while the remaining 36% of the population chose the FPDP. The current therapeutic choice and those carried out in the past were generally in agreement (>70% of cases, P = 0.0001); a relationship was discovered between the anterior and posterior area to the same method of rehabilitation (101 of 107 cases, 94.4%). The WTP median values for ISC were of €3000 and of €2500 in the anterior and posterior areas, respectively. The smallest amount of money has been allocated for FPDP in posterior region (median of €1500). The "importance of oral care" for the patient was a significant predictor, in the regression model analysis, for the estimation of both anterior (P = 0.0003) and posterior (P < 0.0001) WTP values. The "previous therapy" variable reached and was just close to significance in anterior (P = 0.0367) and posterior (P = 0.0511) analyses, respectively. Within the limitations of this study, most of the population (64%) surveyed indicated the ISC as a therapeutic solution for the replacement of a single missing tooth, showing a higher WTP index in the anterior area. Among investigated socio-demographic variables, the importance assigned by the patient to oral care appeared to influence WTP values of the rehabilitation, regardless the location of the single gap in the mouth. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Photopoulos, Christos Demetris; ElAttrache, Neal S.; Doermann, Alex; Akeda, Masaki; McGarry, Michelle H.; Lee, Thay Q.
2017-01-01
Objectives: The rotator cuff cable has been postulated to be the primary load bearing substructure of the superior part of the rotator cuff. Tears of the posterior rotator cable are frequently seen in overhead throwing athletes. Although the biomechanical significance of the anterior rotator cable has been well described, our current understanding of the relevance of the posterior cable is limited. The purpose of this study was to examine how partial-thickness tears and full-thickness tears of the posterior rotator cable would alter glenohumeral biomechanics and kinematics in cadaveric shoulder models. Methods: Eight fresh-frozen cadaveric shoulder specimens were prepared and tested. To simulate the sequence of glenohumeral positions during the throwing motion, specimens were mounted on a custom shoulder testing system with the humerus positioned at 90° of abduction (30° scapular upward rotation, 60° glenohumeral abduction) and tested at 30, 60, 90, and 120 degrees of external rotation. After a circumferential capsulotomy was performed, rotator cuff muscles were loaded based on physiologic cross-sectional area ratios, and testing for each specimen was performed on each the following three conditions: intact posterior cable, partial-thickness (50%) articular-sided posterior cable tear, and full-thickness posterior cable tear. Primary outcome measures tested for each condition under the various degrees of glenohumeral rotation were: 1) anterior and total glenohumeral translation after application of a 30N anterior force; 2) path of glenohumeral articulation; 3) glenohumeral joint force. Results: With a 30N anterior force at 120° of external rotation, there was a significant increase in anterior glenohumeral translation between intact and full-thickness tear specimens (7.28±2.00mm and 17.49±3.75mm, respectively; p<0.05). Similarly, total joint translation at 120° of external rotation significantly increased between intact and full-thickness tear specimens (10.37±3.18mm and 23.37±5.05mm, respectively; p<0.05). No significant differences were apparent at other degrees of rotation (30, 60, 90 degrees), or with partial-thickness tears. Changes in the path of glenohumeral articulation were likewise most evident at 120° of external rotation, with a progressively anterior, inferior, and lateral shift in articulation with sequential sectioning of the posterior cable. Lastly, with regards to alterations in glenohumeral joint force, no significant changes were seen in any of the conditions. Conclusion: In this cadaveric shoulder model of the throwing shoulder, tears of the posterior rotator cuff cable lead to altered glenohumeral biomechanics and kinematics. These changes were most profound at 120° of external rotation, suggesting the importance of an intact posterior cable as a potential stabilizer during the late-cocking phase of throwing.
1974-08-31
Prosthodontic Appliances - Partial Dentures .... ....... ....... .... 59 2. Removable Prosthodontic Appliances - Full Dentures ..... ........... . 60 3...PROCEDURES I This unit includes the following Modules: Number Title Page 1 Removable Prosthodontic Appliances - Partial Dentures 59. ......... ...... 2...Removable Prostbodontic Appliances - Full Dentures ..... ...... a .. .. .. . 60 3 Fixed Prosthodontic Appliances - Fixed Bridge. . 61 4 Mouthquard
Forkel, Philipp; Petersen, Wolf
2012-03-01
According to our observation in ACL reconstruction, we find root tears of the posterior horn of the lateral meniscus as a common concomitant injury in ACL-deficient knees. This might be a consequence of initial trauma or of the increased anterior-posterior translation of the tibia and an overload impact on the posterior meniscus root in ACL-deficient knees. A tear of the posterior horn of the medial meniscus causes a 25% increase in peak pressure in the medial compartment compared with that found in the intact condition. The repair restores the peak contact pressure to normal (Allaire et al. in J Bone Joint Surg Am 90(9):1922-1931, [2008]). A tear of the posterior horn of the lateral meniscus might have similar consequences. We hypothesize the surgical anatomical reattachment of the root at the tibia helping to restore knee joint kinematics and helping to advance ACL-graft function. This article presents an arthroscopical technique to reattach the posterior meniscus root in combination with ACL double-bundle reconstruction. The procedure uses the tibial PL tunnel to fix the meniscus suture.
Kao, Fu-Cheng; Tsai, Tsung-Ting; Niu, Chi-Chien; Lai, Po-Liang; Chen, Lih-Huei; Chen, Wen-Jer
2017-10-01
Treating thoracic infective spondylodiscitis with anterior surgical approaches carry a relatively high risk of perioperative and postoperative complications. Posterior approaches have been reported to result in lower complication rates than anterior procedures, but more evidence is needed to demonstrate the safety and efficacy of 1-stage posterior approaches for treating infectious thoracic spondylodiscitis.Preoperative and postoperative clinical data, of 18 patients who underwent 2 types of 1-stage posterior procedures, costotransversectomy and transforaminal thoracic interbody debridement and fusion and 7 patients who underwent anterior debridement and reconstruction with posterior instrumentation, were retrospectively assessed.The clinical outcomes of patients treated with 1-stage posterior approaches were generally good, with good infection control, back pain relief, kyphotic angle correction, and either partial or solid union for fusion status. Furthermore, they achieved shorter surgical time, fewer postoperative complications, and shorter hospital stay than the patients underwent anterior debridement with posterior instrumentation.The results suggested that treating thoracic spondylodiscitis with a single-stage posterior approach might prevent postoperative complications and avoid respiratory problems associated with anterior approaches. Single-stage posterior approaches would be recommended for thoracic spine infection, especially for patients with medical comorbidities.
Bacchi, Ataís; Consani, Rafael Leonardo Xediek; Mesquita, Marcelo Ferraz; Dos Santos, Mateus Bertolini Fernandes
2013-09-01
This study evaluated the influence of framework material and vertical misfit on stress created in an implant-supported partial prosthesis under load application. The posterior part of a severely reabsorbed jaw with a fixed partial prosthesis above two osseointegrated titanium implants at the place of the second premolar and second molar was modeled using SolidWorks 2010 software. Finite element models were obtained by importing the solid model into an ANSYS Workbench 11 simulation. The models were divided into 15 groups according to their prosthetic framework material (type IV gold alloy, silver-palladium alloy, commercially pure titanium, cobalt-chromium alloy or zirconia) and vertical misfit level (10 µm, 50 µm and 100 µm). After settlement of the prosthesis with the closure of the misfit, simultaneous loads of 110 N vertical and 15 N horizontal were applied on the occlusal and lingual faces of each tooth, respectively. The data was evaluated using Maximum Principal Stress (framework, porcelain veneer and bone tissue) and a von Mises Stress (retention screw) provided by the software. As a result, stiffer frameworks presented higher stress concentrations; however, these frameworks led to lower stresses in the porcelain veneer, the retention screw (faced to 10 µm and 50 µm of the misfit) and the peri-implant bone tissues. The increase in the vertical misfit resulted in stress values increasing in all of the prosthetic structures and peri-implant bone tissues. The framework material and vertical misfit level presented a relevant influence on the stresses for all of the structures evaluated.
Fixed Point Results of Locally Contractive Mappings in Ordered Quasi-Partial Metric Spaces
Arshad, Muhammad; Ahmad, Jamshaid
2013-01-01
Fixed point results for a self-map satisfying locally contractive conditions on a closed ball in an ordered 0-complete quasi-partial metric space have been established. Instead of monotone mapping, the notion of dominated mappings is applied. We have used weaker metric, weaker contractive conditions, and weaker restrictions to obtain unique fixed points. An example is given which shows that how this result can be used when the corresponding results cannot. Our results generalize, extend, and improve several well-known conventional results. PMID:24062629
NASA Technical Reports Server (NTRS)
Maklad, Adel; Fritzsch, Bernd
2003-01-01
The projection of the posterior canal crista and saccular afferents to the cerebellum of embryonic and neonatal mice was investigated using carbocyanine dyes. Anterograde tracing from these two endorgans reveals a partial segregation of these two sets of afferents. The saccule projects predominantly to the uvula, with very minor input to the nodulus. The posterior canal projects mainly to the nodulus and, to a lesser extent, to the uvula. Retrograde tracing from the uvula and nodulus confirms this partial segregation for these two endorgans and extends it to other vestibular endorgans. Uvular injections result in many more labeled fibers in the gravistatic maculae than in the canals' cristae. In contrast, nodular injection reveals many more labeled fibers in the canal cristae than in the gravistatic maculae. This partial segregation may play a role in the information processing in these folia. Our developmental data suggest that the initial segregation at E17 coincides with the formation of the postero-lateral fissure. This embryonic segregation of the primary vestibular mossy fibers to the uvula and nodulus commences long before the maturity of their targets, the granule cells and unipolar brush cells. Thus, the segregation of the primary vestibular projection to the uvula and nodulus does not depend on cues related to the target cells. Rather, the segregation may reflect more global cerebellar patterning mechanisms involving guidance for the vestibular afferent fibers independent of the future target cells.
Riedl, Markus; Glisson, Richard R; Matsumoto, Takumi; Hofstaetter, Stefan G; Easley, Mark E
2017-06-01
Subtalar joint arthrodesis is a common operative treatment for symptomatic subtalar arthrosis. Because excessive relative motion between the talus and calcaneus can delay or prohibit fusion, fixation should be optimized, particularly in patients at risk for subtalar arthrodesis nonunion. Tapered, fully-threaded, variable pitch screws are gaining popularity for this application, but the mechanical properties of joints fixed with these screws have not been characterized completely. We quantified the torsion resistance of 2-screw and 3-screw subtalar joint fixation using this type of screw. Ten pairs of cadaveric subtalar joints were prepared for arthrodesis and fixed using Acutrak 2-7.5 screws. One specimen from each pair was fixed with two diverging posterior screws, and the contralateral joint was fixed using two posterior screws and a third screw directed through the anterior calcaneus into the talar neck. Internal and external torsional loads were applied and joint rotation and torsional stiffness were measured at two torque levels. Internal rotation was significantly less in specimens fixed with three screws. No difference was detectable between 2-screw and 3-screw fixation in external rotation or torsional stiffness in either rotation direction. Both 2-screw and 3-screw fixation exhibited torsion resistance surpassing that reported previously for subtalar joints fixed with two diverging conventional lag screws. Performance of the tapered, fully threaded, variable pitch screws exceeded that of conventional lag screws regardless of whether two or three screws were used. Additional resistance to internal rotation afforded by a third screw placed anteriorly may offer some advantage in patients at risk for nonunion. Copyright © 2017. Published by Elsevier Ltd.
Dental Laboratory Career Ladder (AFSC 4Y1X1)
1994-08-01
analysis identified one job cluster and seven jobs: Base Dental Lab cluster, Orthodontic Appliance Fabricator job, Fixed Restoration Fabricator job, Crown...reline and repair, removable partial denture construction, crown and fixed partial denture construction, fabrication of orthodontic appliances, and...specialized prostheses. Preventive maintenance and safety precautions for dental laboratory equipment are also stressed . Entry into the career ladder
Nyangoh Timoh, Krystel; Ballester, Marcos; Bendifallah, Sofiane; Fauconnier, Arnaud; Darai, Emile
2018-01-01
To evaluate fertility outcomes after laparoscopic partial bladder resection in women with bladder endometriosis and to review the literature. A retrospective study conducted at two tertiary referral centres -Tenon University Hospital and Poissy University Hospital (Canadian Task Force Classification Level II-2)-from July 2006 to November 2015. Patients with bladder endometriosis who underwent either laparoscopic partial bladder resection (PBR) alone for those without posterior endometriotic lesions (PBR group) or both laparoscopic PBR and associated posterior deep infiltrating endometriosis (DIE) resection (PBR-PDIE group) were included. Pregnancy and live birth rates according to prior infertility, and associated posterior DIE resection were analysed. Thirty-four patients were included; 15 in the PBR group and 19 in the PBR-PDIE group. The median age (range) was 31 years (25-37), Seventeen patients (50%) had prior infertility. The median follow-up after bladder resection was 60.6 months (12-116). Overall, of the 25 (73.5%) patients who wished to conceive, 17 (68%) achieved pregnancies resulting in a live birth rate of 76.4%. Among the 17 patients with prior infertility, nine (52.9%) conceived. Overall, eight patients (53.3%) in the PBR group conceived and nine (47.3%) in the PBR-PDIE group (difference not significant). The present study demonstrates that laparoscopic PBR results in a high pregnancy rate in patients with prior infertility as well as in those with associated posterior DIE suggesting that surgery could be an acceptable alternative to first-line assisted reproductive technology. Copyright © 2017 Elsevier B.V. All rights reserved.
Zimmermann, Richard; Seitz, Stefanie; Magness, Brent; Wieck, Blaine
2013-10-01
From diagnosis and treatment planning to the materials being used, technology is changing dentistry. New materials are providing dentists greater options for treatment, while technology is streamlining the workflow in the office and dental laboratory. Traditionally the creation of a long-span fixed partial denture was a labor intense project--from waxing up the prosthesis--to stacking of the porecelain. For larger frameworks, it was recommended for the dentist to bring in the patient in for a framework try-in. However, advances in both CAD/CAM technology and dental materials are revolutionizing the way dentistry is being done. The following describes the fabrication of a 10-unit full contour zirconia fixed partial denture completed in the pre-doctorate program at UTHSCSA Dental School.
[Ultrastructure of the digestive system in Dermatophagoides farinae (Acariformes:Pyroglyphidae)].
Wang, Yue-Ming; Liu, Xiao-Yu; Jiang, Cong-Li; Huang, Li-Nian; Sun, Xin; Liu, Zhi-Gang
2013-12-01
Fifty living mites (Dermatophagoides farinae) were fixed in 2.5% glutaraldehyde, postfixed in 1% osmium tetroxide, dehydrated in a graded ethanol series, embedded in embedding medium. The ultrastructure of the digestive tract in D. farinae was observed by serial ultrathin sections with a transmission electron microscope. The alimentary canal of D. farinae consists of the cuticle-lined foregut and hindgut separated by a microvilli-lined midgut (anterior midgut, posterior midgut). There are different types of epithelial cells in the anterior midgut The microvilli of epithelial cells in posterior midgut are longer than that of the anterior midgut In posterior midgut, the food bolus is surrounded by the peritrophic membrane. The midgut is the main site of digestion and absorption.
Sotomayor-González, Arturo; Díaz-Martínez, Armando José; Radillo-Gil, Ramón; García-Estrada, Everardo; Morales-Gómez, Jesús Alberto; Palacios-Ortiz, Isaac Jair; Pérez-Cárdenas, Samuel; Arteaga-Treviño, Mauricio; De León, Ángel Martínez-Ponce
2016-01-01
Objective Report a modification of the “rescue flap” technique using a direct endonasal approach with a partial superior septectomy for approaching pituitary tumors developed in our institution. Design Prospective study. Setting Hospital Universitario “Dr. José Eleuterio González,” Universidad Autónoma de Nuevo León. Main Outcome Measures Since April 2015, we have performed 19 cases employing a direct endonasal approach with partial superior septectomy. Results and a technical note are described below. Results Nineteen patients were included in this report. Six patients presented transoperatory cerebrospinal fluid (CSF) leak, so a nasoseptal rescue flap was harvested. No patients developed postoperative CSF leak in this group. Two patients were submitted to a second surgical procedure. Nasoseptal flap was harvested without complications. In both patients, the size of the flap was enough to cover the dural defect and avoid CSF leak. Conclusion Direct endonasal approach with a partial posterior septectomy allows enough exposition of the sphenoidal sinus while preserving the nasoseptal septum with the possibility of a successful rescue flap when needed. PMID:28321383
Sotomayor-González, Arturo; Díaz-Martínez, Armando José; Radillo-Gil, Ramón; García-Estrada, Everardo; Morales-Gómez, Jesús Alberto; Palacios-Ortiz, Isaac Jair; Pérez-Cárdenas, Samuel; Arteaga-Treviño, Mauricio; De León, Ángel Martínez-Ponce
2017-04-01
Objective Report a modification of the "rescue flap" technique using a direct endonasal approach with a partial superior septectomy for approaching pituitary tumors developed in our institution. Design Prospective study. Setting Hospital Universitario "Dr. José Eleuterio González," Universidad Autónoma de Nuevo León. Main Outcome Measures Since April 2015, we have performed 19 cases employing a direct endonasal approach with partial superior septectomy. Results and a technical note are described below. Results Nineteen patients were included in this report. Six patients presented transoperatory cerebrospinal fluid (CSF) leak, so a nasoseptal rescue flap was harvested. No patients developed postoperative CSF leak in this group. Two patients were submitted to a second surgical procedure. Nasoseptal flap was harvested without complications. In both patients, the size of the flap was enough to cover the dural defect and avoid CSF leak. Conclusion Direct endonasal approach with a partial posterior septectomy allows enough exposition of the sphenoidal sinus while preserving the nasoseptal septum with the possibility of a successful rescue flap when needed.
Democratic Superstring Field Theory and Its Gauge Fixing
NASA Astrophysics Data System (ADS)
Kroyter, M.
This work is my contribution to the proceedings of the conference``SFT2010 -- the third international conference on string field theory and related topics'' and it reflects my talk there, which described the democratic string field theory and its gauge fixing. The democratic string field theory is the only fully RNS string field theory to date. It lives in the large Hilbert space and includes all picture numbers. Picture changing amounts in this formalism to a gauge transformation. We describe the theory and its properties and show that when partially gauge fixed it can be reduced to the modified theory and to the non-polynomial theory. In the latter case we can even include the Ramond sector in the picture-fixed action. We also show that another partial gauge-fixing leads to a new consistent string field theory at picture number -1.
Partial hammock valve: surgical repair in adulthood.
Aramendi, José I; Rodríguez, Miguel A; Voces, Roberto; Pérez, Pedro; Rodrigo, David
2006-09-01
We describe a forme frustrée of hammock valve involving only the posterior mitral leaflet. Three adult patients were referred to surgery with the diagnosis of severe mitral regurgitation due to fibrosis of the posterior mitral leaflet. The final diagnosis was done intraoperatively. In all of them the posterior leaflet was attached to some accessory papillary muscles arranged en palisade, with three to four fused muscle heads producing restrictive leaflet motion in systole. Repair consisted in division of the papillary muscles, patch augmentation, and ring annuloplasty. This previously unreported lesion is congenital but manifests itself in adulthood.
Vigolo, Paolo; Mutinelli, Sabrina
2012-06-01
The purpose of this prospective clinical study was to determine the success rate of single-unit posterior fixed dental prostheses (FDPs) with zirconia copings generated with two CAD/CAM systems, compared to porcelain-fused-to-metal (PFM) single-unit posterior FDPs after 5 years of function. From 2005 to 2006, 60 patients who needed a single-unit FDP on a first molar in the mandibular jaw (left or right) in a private office setting were included in this study. The 60 first mandibular molars were randomly divided into three groups (n = 20): in the control group (group C), 20 PFM FDPs were included. In the other two groups CAD/CAM technology was used for the fabrication of the zirconium-oxide copings: 20 single-unit posterior FDPs with zirconia copings were generated with the Procera system (group P, Nobel Biocare); 20 single-unit posterior FDPs with zirconia copings were generated with the Lava system (group L, 3M ESPE). For the ANOVA follow-up data, the clinical life table method was applied. The statistical analysis was performed using two nonparametric tests, the log-rank test for k-groups and the Fisher exact test. No statistically significant difference in the clinical outcome of zirconia-ceramic FDPs of both groups (P and L) evaluated together and metal-ceramic posterior single FDPs was found at 5 years of function; however, clinical data showed that technical problems, such as extended fracture of the veneering ceramic, tended to occur more frequently in the zirconia-ceramic FDP groups. The difference in the frequency of failure was statistically significant only in the comparison of groups C and P. Even if no statistically significant difference in the clinical outcome of zirconia-ceramic FDPs of both groups (P and L) considered together and metal-ceramic posterior single FDPs was found at 5 years of function, clinical data showed that the two zirconia-ceramic FDP groups tended to have more frequent clinical problems: for this reason all the clinical and technical variables related to the use of zirconia-ceramic FDPs generated with CAD/CAM systems should be carefully considered prior to all treatment procedures. © 2012 by the American College of Prosthodontists.
The Effect of Framework Design on Stress Distribution in Implant-Supported FPDs: A 3-D FEM Study
Eraslan, Oguz; Inan, Ozgur; Secilmis, Asli
2010-01-01
Objectives: The biomechanical behavior of the superstructure plays an important role in the functional longevity of dental implants. However, information about the influence of framework design on stresses transmitted to the implants and supporting tissues is limited. The purpose of this study was to evaluate the effects of framework designs on stress distribution at the supporting bone and supporting implants. Methods: In this study, the three-dimensional (3D) finite element stress analysis method was used. Three types of 3D mathematical models simulating three different framework designs for implant-supported 3-unit posterior fixed partial dentures were prepared with supporting structures. Convex (1), concave (2), and conventional (3) pontic framework designs were simulated. A 300-N static vertical occlusal load was applied on the node at the center of occlusal surface of the pontic to calculate the stress distributions. As a second condition, frameworks were directly loaded to evaluate the effect of the framework design clearly. The Solidworks/Cosmosworks structural analysis programs were used for finite element modeling/analysis. Results: The analysis of the von Mises stress values revealed that maximum stress concentrations were located at the loading areas for all models. The pontic side marginal edges of restorations and the necks of implants were other stress concentration regions. There was no clear difference among models when the restorations were loaded at occlusal surfaces. When the veneering porcelain was removed, and load was applied directly to the framework, there was a clear increase in stress concentration with a concave design on supporting implants and bone structure. Conclusions: The present study showed that the use of a concave design in the pontic frameworks of fixed partial dentures increases the von Mises stress levels on implant abutments and supporting bone structure. However, the veneering porcelain element reduces the effect of the framework and compensates for design weaknesses. PMID:20922156
Gao, Kai-Ming; Lao, Jie; Guan, Wen-Jie; Hu, Jing-Jing
2018-01-01
If a partial contralateral C 7 nerve is transferred to a recipient injured nerve, results are not satisfactory. However, if an entire contralateral C 7 nerve is used to repair two nerves, both recipient nerves show good recovery. These findings seem contradictory, as the above two methods use the same donor nerve, only the cutting method of the contralateral C 7 nerve is different. To verify whether this can actually result in different repair effects, we divided rats with right total brachial plexus injury into three groups. In the entire root group, the entire contralateral C 7 root was transected and transferred to the median nerve of the affected limb. In the posterior division group, only the posterior division of the contralateral C 7 root was transected and transferred to the median nerve. In the entire root + posterior division group, the entire contralateral C 7 root was transected but only the posterior division was transferred to the median nerve. After neurectomy, the median nerve was repaired on the affected side in the three groups. At 8, 12, and 16 weeks postoperatively, electrophysiological examination showed that maximum amplitude, latency, muscle tetanic contraction force, and muscle fiber cross-sectional area of the flexor digitorum superficialis muscle were significantly better in the entire root and entire root + posterior division groups than in the posterior division group. No significant difference was found between the entire root and entire root + posterior division groups. Counts of myelinated axons in the median nerve were greater in the entire root group than in the entire root + posterior division group, which were greater than the posterior division group. We conclude that for the same recipient nerve, harvesting of the entire contralateral C 7 root achieved significantly better recovery than partial harvesting, even if only part of the entire root was used for transfer. This result indicates that the entire root should be used as a donor when transferring contralateral C 7 nerve.
Gao, Kai-ming; Lao, Jie; Guan, Wen-jie; Hu, Jing-jing
2018-01-01
If a partial contralateral C7 nerve is transferred to a recipient injured nerve, results are not satisfactory. However, if an entire contralateral C7 nerve is used to repair two nerves, both recipient nerves show good recovery. These findings seem contradictory, as the above two methods use the same donor nerve, only the cutting method of the contralateral C7 nerve is different. To verify whether this can actually result in different repair effects, we divided rats with right total brachial plexus injury into three groups. In the entire root group, the entire contralateral C7 root was transected and transferred to the median nerve of the affected limb. In the posterior division group, only the posterior division of the contralateral C7 root was transected and transferred to the median nerve. In the entire root + posterior division group, the entire contralateral C7 root was transected but only the posterior division was transferred to the median nerve. After neurectomy, the median nerve was repaired on the affected side in the three groups. At 8, 12, and 16 weeks postoperatively, electrophysiological examination showed that maximum amplitude, latency, muscle tetanic contraction force, and muscle fiber cross-sectional area of the flexor digitorum superficialis muscle were significantly better in the entire root and entire root + posterior division groups than in the posterior division group. No significant difference was found between the entire root and entire root + posterior division groups. Counts of myelinated axons in the median nerve were greater in the entire root group than in the entire root + posterior division group, which were greater than the posterior division group. We conclude that for the same recipient nerve, harvesting of the entire contralateral C7 root achieved significantly better recovery than partial harvesting, even if only part of the entire root was used for transfer. This result indicates that the entire root should be used as a donor when transferring contralateral C7 nerve. PMID:29451212
Bodon, Gergely; Grimm, Andras; Hirt, Bernhard; Seifarth, Harald; Barsa, Pavel
2016-10-01
To present a method of posterior arch and lateral mass screw (PALMS) insertion and to prove its feasibility. Four formalin-fixed specimens and 40 macerated atlas vertebras were used to describe the relevant anatomy. The height of the posterior arch was measured on 42 consecutive patients using standard CT of the cervical spine. The operative technique and the special CT reconstructions used for preoperative planning are described. Eight patients underwent posterior fixation using this technique. We described the relevant anatomy and important anatomical landmarks of the posterior arch of the atlas. PALMS placement was modified according to these anatomical findings. Fifteen PALMSs were placed in eight patients using this technique without vascular or neural injury. It is feasible to place PALMS using the described technique. CT angiography is of crucial importance for preoperative planning using the described special reconstructions. The arch posterior to the lateral mass (APLM) is defined as the bone stock situated posterior to the lateral mass, respecting its convergence. The ideal entry point for a PALMS is on the APLM above the center of the converging lateral mass. A complete or incomplete ponticulus posticus and a retrotransverse foramen or groove can be used as an accessory landmark to refine the entry point.
Optimal strategies for the control of autonomous vehicles in data assimilation
NASA Astrophysics Data System (ADS)
McDougall, D.; Moore, R. O.
2017-08-01
We propose a method to compute optimal control paths for autonomous vehicles deployed for the purpose of inferring a velocity field. In addition to being advected by the flow, the vehicles are able to effect a fixed relative speed with arbitrary control over direction. It is this direction that is used as the basis for the locally optimal control algorithm presented here, with objective formed from the variance trace of the expected posterior distribution. We present results for linear flows near hyperbolic fixed points.
Habit Breaking Appliance for Multiple Corrections
Abraham, Reji; Kamath, Geetha; Sodhi, Jasmeet Singh; Sodhi, Sonia; Rita, Chandki; Sai Kalyan, S.
2013-01-01
Tongue thrusting and thumb sucking are the most commonly seen oral habits which act as the major etiological factors in the development of dental malocclusion. This case report describes a fixed habit correcting appliance, Hybrid Habit Correcting Appliance (HHCA), designed to eliminate these habits. This hybrid appliance is effective in less compliant patients and if desired can be used along with the fixed orthodontic appliance. Its components can act as mechanical restrainers and muscle retraining devices. It is also effective in cases with mild posterior crossbites. PMID:24198976
Costa, Julia Garcia; Galindo, Thaís Magalhães; Mattos, Claudia Trindade; Cury-Saramago, Adriana de Alcantara
2017-01-01
The aim of this systematic review was to evaluate the duration of the retention period in growing patients undergoing maxillary expansion and its relation with posterior crossbite stability. Search strategies were executed for electronic databases Cochrane Library, Web of Science, PubMed and Scopus, which were completed on January 15, 2016. The inclusion criteria included randomized, prospective or retrospective controlled trials in growing subjects with posterior crossbite; treated with maxillary expanders; retention phase after expansion; post-retention phase of at least 6 months. The exclusion criteria were anterior crossbite, craniofacial anomalies, surgery or another orthodontic intervention; case reports; author's opinions articles, thesis, literature reviews and systematic reviews. The risk of bias of selected articles was assessed with Cochrane risk of bias tool for RCTs and Downs and Black checklist for non-RCTs. A total of 156 titles/abstracts was retrieved, 44 full-texts were examined, and 6 articles were selected and assessed for their methodological quality. The retention period after maxillary expansion ranged between 4 weeks and 16 months. Fixed (acrylic plate, Haas, Hyrax and quad-helix) or removable (Hawley and Hawley expander) appliances were used for retention. Six months of retention with either fixed or removable appliances seem to be enough to avoid relapse or to guarantee minimal changes in a short-term follow-up.
Partial-coverage posterior ceramic restorations. Part 1: a return to diligence.
Liebenberg, W H
2001-01-01
The application of multisurfaced tooth-colored restorations in the posterior dentition is an exercise in risk tolerance when dentin occupies the bulk of the tooth substrate. Not only is interfacial integrity capricious, but also a recent in vivo study has confirmed that dentin bond strengths deteriorate with time. Although the literature is replete with esthetic guidelines for posterior restitution, most practicing clinicians appreciate the prime tenet that clinical success involves more than esthetic realism in the posterior dentition. Success with indirect ceramic restorations is dependent on interfacial integrity, which, although multitudinous, is contingently related to operative competence. Innovative clinical techniques are described in this two-part article, along with a discussion of the probationary status of current adhesive options and the need for excellence in all phases of this demanding restorative sequence. Restorative success in the posterior dentition is profoundly influenced by the variability of operative competence and diligence. This article discusses the precincts of posterior indirect ceramic restorations and submits a number of innovative solutions to the clinical challenge.
Schuh, Cristian; Adiel Skupien, Jovito; Mesko, Mauro Elias; Valentini, Fernanda; Pereira-Cenci, Tatiana; Boscato, Noéli
2014-12-01
The present clinical report describes the prosthodontic management for a patient with uncontrolled bleeding and diabetes mellitus treated with a maxillary complete denture and a mandibular partial fixed dental prosthesis designed to interface with a removable cast framework partial denture retained by 2 ERA attachments. This approach was undertaken to improve both retention and stability of the distal extension Kennedy Class I removable partial denture. The rehabilitation provided better anterior esthetics than if treated with a conventional clasp retained removable partial denture, by employing a simple, practical design and offering a significant biomechanical advantages, restoring both oral health and function. Thus, this treatment modality, involving an ERA system and transfixation in fixed crowns, is an effective treatment and can be indicated as a clinical alternative for edentulous and partially edentulous patients with systemic disorders or for patients in economic situations that might preclude implant-based rehabilitation.
A provisional fixed partial denture that simulates gingival tissue at the pontic-site defect.
Haj-Ali, Reem; Walker, Mary P
2002-03-01
A technique is presented for the fabrication of an esthetic, provisional fixed partial denture that compensates for a pontic-site ridge defect. This provisional restoration enables both the dentist and the patient to evaluate whether this prosthetic approach will adequately camouflage the pontic-site defect or whether surgical correction of the pontic site should also be considered. Copyright 2002 by The American College of Prosthodontists.
Fraser, Sheila; Norlén, Olov; Bender, Kyle; Davidson, Joanne; Bajenov, Sonya; Fahey, David; Li, Shawn; Sidhu, Stan; Sywak, Mark
2018-05-01
Posterior retroperitoneoscopic adrenalectomy has gained widespread acceptance for the removal of benign adrenal tumors. Higher insufflation pressures using carbon dioxide (CO 2 ) are required, although the ideal starting pressure is unclear. This prospective, randomized, single-blinded, study aims to compare physiologic differences with 2 different CO 2 insufflation pressures during posterior retroperitoneoscopic adrenalectomy. Participants were randomly assigned to a starting insufflation pressure of 20 mm Hg (low pressure) or 25 mm Hg (high pressure). The primary outcome measure was partial pressure of arterial CO 2 at 60 minutes. Secondary outcomes included end-tidal CO 2 , arterial pH, blood pressure, and peak airway pressure. Breaches of protocol to change insufflation pressure were permitted if required and were recorded. A prospective randomized trial including 31 patients (low pressure: n = 16; high pressure: n = 15) was undertaken. At 60 minutes, the high pressure group had greater mean partial pressure of arterial CO 2 (64 vs 50 mm Hg, P = .003) and end-tidal CO 2 (54 vs 45 mm Hg, P = .008) and a lesser pH (7.21 vs 7.29, P = .0005). There were no significant differences in base excess, peak airway pressure, operative time, or duration of hospital stay. Clinically indicated protocol breaches were more common in the low pressure than the high pressure group (8 vs 3, P = .03). In posterior retroperitoneoscopic adrenalectomy, greater insufflation pressures are associated with greater partial pressure of arterial CO 2 and end-tidal CO 2 and lesser pH at 60 minutes, be significant. Commencing with lesser CO 2 insufflation pressures decreases intraoperative acidosis. Copyright © 2017 Elsevier Inc. All rights reserved.
Nakao, Yaoki; Shimokawa, Nobuyuki; Morisako, Hiroki; Tsukazaki, Yuji; Terada, Aiko; Nakajo, Kosuke; Fu, Yoshihiko
2014-01-01
Objective Polyaxial screw-rod fixation of C1-C2 is a relatively new technique to treat atlantoaxial instability, and there have been few reports in the literature outlining all possible complications. The purpose of this case report is to present the occurrence and management of occipital bone erosion induced by the protruded rostral part of a posterior atlantoaxial screw-rod construct causing headache. Clinical Features A 70-year-old Asian man with rheumatoid arthritis initially presented to our institution with atlantoaxial instability causing progressive quadraparesis and neck pain. Intervention and Outcome Posterior atlantoaxial instrumented fixation using C1 lateral mass screws in conjunction with C2 pedicle screws was performed to stabilize these segments. Postoperatively, the patient regained the ability to independently walk and had no radiographic evidence of instrumentation hardware failure and excellent sagittal alignment. However, despite a well-stabilized fusion, the patient began to complain of headache during neck extension. Follow-up imaging studies revealed left occipital bone erosion induced by a protruded titanium rod fixed with setscrews. During revision surgery, the rod protrusion was modified and the headaches diminished. Conclusion This case demonstrates that occipital bone erosion after posterior atlantoaxial fixation causing headache may occur. The principal cause of bone erosion in this case was rod protrusion. Although posterior atlantoaxial fixation using the screw-rod system was selected to manage atlantoaxial instability because it has less complications than other procedures, surgeons should pay attention that the length of the rod protrusion should not exceed 2 mm. PMID:25435842
Five-year prospective clinical study of posterior three-unit zirconia-based fixed dental prostheses.
Sorrentino, Roberto; De Simone, Giorgio; Tetè, Stefano; Russo, Simona; Zarone, Fernando
2012-06-01
This prospective clinical trial aimed at evaluating the clinical performance of three-unit posterior zirconia fixed dental prostheses (FDPs) after 5 years of clinical function. Thirty-seven patients received 48 three-unit zirconia-based FDPs. The restorations replaced either a premolar or a molar. Specific inclusion criteria were needed. Tooth preparation was standardized. Computer-aided design/computer-assisted manufacturing frameworks with a 9-mm(2) cross section of the connector and a 0.6-mm minimum thickness of the retainer were made. The restorations were luted with resin cement. The patients were recalled after 1, 6, 12, 24, 36, 48, and 60 months. The survival and success of the ceramics and zirconia were evaluated. The technical and aesthetic outcomes were examined using the United States Public Health Service criteria. The biologic outcomes were analyzed at abutment and contralateral teeth. Descriptive statistics were performed. All FDPs completed the study, resulting in 100% cumulative survival rate and 91.9% and 95.4% cumulative success rates for patients wearing one and two FDPs, respectively. No losses of retention were recorded. Forty-two restorations were rated alpha in all measured parameters. A minor chipping of the ceramics was detected in three restorations. No significant differences between the periodontal parameters of the test and control teeth were observed. Five-year clinical results proved that three-unit posterior zirconia-based FDPs were successful in the medium term for both function and aesthetic. Zirconia can be considered a promising substitute of metal frameworks for the fabrication of short-span posterior prostheses.
Xu, Yong; Li, Feng; Guan, Hanfeng; Xiong, Wei
2015-01-01
Abstract Posterior atlantoaxial dislocation without odontoid fracture is extremely rare and often results in fatal spinal cord injury. According to the reported literature, all cases presented mild or no neurologic deficit, with no definite relation to upper spinal cord injury. Little is reported about traumatic posterior atlantoaxial dislocation, with incomplete quadriplegia associated with a spinal cord injury. We present a case of posterior atlantoaxial dislocation without associated fracture, but with quadriplegia, and accompanying epidural hematoma and subarachnoid hemorrhage. The patient underwent gentle traction in the neutral position until repeated cranial computed tomography revealed no progression of the epidural hematoma. Thereafter, the atlantoaxial dislocation was reduced by using partial odontoidectomy via a video-assisted transcervical approach and maintained with posterior polyaxial screw-rod constructs and an autograft. Neurological status improved immediately after surgery, and the patient recovered completely after 1 year. Posterior fusion followed by closed reduction is the superior strategy for posterior atlantoaxial dislocation without odontoid fracture, according to literature. But for cases with severe neurological deficit, open reduction may be the safest choice to avoid the lethal complication of overdistraction of the spinal cord. Also, open reduction and posterior srew-rod fixation are safe and convenient strategies in dealing with traumatic posterior atlantoaxial dislocation patients with neurological deficit. PMID:26512572
Shilal, Poonam; Tuli, Anita
2015-03-01
The pattern of drainage in the right posterior lobe of liver varies considerably. The knowledge of this variation is very important while performing various surgeries on the right posterior lobe. A study was conducted to see the variations in the pattern of drainage of posterior segment of the right lobe of liver. The aim was to see the variations of right hepatic vein and small accessory hepatic veins draining the posterior segment, the presence of which led to modifications in drainage of posterior segment. Sixty formalin fixed adult human liver specimens were dissected manually. According to the pattern of drainage of tributaries of right hepatic vein, the right hepatic vein was classified into type I, type II, type III and type IV. According to presence of inferior right hepatic vein, three types of drainage of posterior lobe were seen: Type I, (76.36%) right hepatic vein was large, draining wide area of posterior segment. A small inferior right hepatic vein drained the small area of posterior segment. In Type II, (19.92%) both right hepatic and inferior right hepatic veins were medium sized draining the posteroinferior segment of the right lobe concomitantly. In Type III, (32%) accessory veins, the middle right hepatic vein drained the posterosuperior (VII) as well as the posteroinferior (VI) segment. In one specimen, there were numerous middle right hepatic veins draining the right posterior segment. The knowledge of anatomic relationship of veins draining right lobe, is important in performing right posterior segmentectomy. For safe resection of the liver, the complex anatomy of the distribution of the tributaries of the right hepatic vein and the accessory veins have to be studied prior to any surgery done on liver.
Urethral injury in the multiple-injured patient.
Cass, A S
1984-10-01
A total of 74 patients with urethral injury due to external trauma consisted of 48 posterior urethral injuries (25 complete rupture, 23 partial rupture) and 26 anterior urethral injuries (two complete rupture, 16 partial rupture, and eight contusion). The diagnosis was made by retrograde urethrography. All 48 patients with posterior urethral injury had associated injuries, including a fractured pelvis in 46, and a mortality rate of 33%. Only seven of the 26 patients with anterior urethral injury had associated injuries and a mortality rate of 14%. The management of posterior urethral injury is changing from primary realignment of the ruptured urethra to suprapubic cystostomy alone and followed later by urethral surgery for the resulting stricture. The impotence rate is significantly lower with management with suprapubic cystostomy alone. However, the type of pelvic fracture, the urethral injury itself disrupting neurovascular structures, and the surgical dissection (initial primary realignment or delayed urethroplasty) must be investigated before it can be determined whether the impotence associated with pelvic trauma is caused by the injury itself or by the surgical dissection undertaken to reconstruct the urethra.
Fueki, K; Baba, K
2017-07-01
This systematic review aimed to compare oral health-related quality of life (OHRQoL) between two tooth replacement strategies - the shortened dental arch (SDA) concept and conventional treatment with removable partial dental prosthesis (RPDP) or implant-supported fixed partial dental prosthesis (IFPDP) - for distal extension of edentulous space in the posterior area. We retrieved eligible randomised controlled trials (RCTs) and non-RCTs published between 1980 and November 2016 retrieved from MEDLINE and the Cochrane Central Register of Controlled Trials. The primary outcome was OHRQoL evaluated using validated questionnaires. Two reviewers independently screened and selected the articles, evaluated the risk of bias and determined the standardised weighted mean difference (SWMD) in OHRQoL scores between the two strategies using a random effects model. Two RCTs and one non-RCT involving 516 participants were included in this review. All studies employed the oral health impact profile (OHIP) for evaluation of OHRQoL. There was no statistically significant difference in OHIP summary scores between SDA and RPDP at 6 (SWMD = 0·24) or 12 (SWMD = 0·40) months post-treatment. Only one non-RCT had reported higher OHRQoL with IFPDP than with SDA; however, because of the small sample size, there was no significant difference in OHIP summary scores between the two strategies at 6 (SWMD = -0·59) or 12 (SWMD = -0·67) months post-treatment. In terms of OHRQoL in partially dentate patients, the SDA concept appears to be as feasible as RPDP restoration. Further clinical trials are required to clarify the effect of IFPDP restoration on OHRQoL. © 2017 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Sinescu, Cosmin; Negrutiu, Meda; Hughes, Michael; Bradu, Adrian; Todea, Carmen; Rominu, Mihai; Laissue, Philippe L.; Podoleanu, Adrian Gh.
2008-04-01
Metal ceramic and integral ceramic fixed partial prostheses are mainly used in the frontal part of the dental arch because for esthetics reasons. The masticatory stress may induce fractures of the bridges. There are several factors that are associated with the stress state created in ceramic restorations, including: thickness of ceramic layers, mechanical properties of the materials, elastic modulus of the supporting substrate material, direction, magnitude and frequency of applied load, size and location of occlusal contact areas, residual stresses induced by processing or pores, restoration-cement interfacial defects and environmental defects. The fractures of these bridges lead to functional, esthetic and phonetic disturbances which finally render the prosthetic treatment inefficient. The purpose of this study is to evaluate the capability of optical coherence tomography (OCT) in detection and analysis of possible material defects in metal-ceramic and integral ceramic fixed partial dentures.
Dronen, Norman O; Al-Kassar, Nothiala R; Ali, Atheer H; Abdulhameed, Mohanad F; Abdullah, Basim H; Al-Mayah, Sabeeh H
2017-03-09
A total of 19 white-tailed lapwing, Vanellus leucurus, were collected from Huwazah Marsh, north-eastern Basrah Province, Iraq from February to March and in October, 2011 (collection site #1) and 60 V. leucurus were collected from Al-Hammar Marshes, Thi-Qar Province, southern Iraq from July to November, 2012 (collection site #2), and examined for cyclocoelids. Nineteen Uvitellina iraquensis Dronen, Ali & Al-Amura, 2013 from site #1 and 17 specimens from site #2 were fixed with minimal compression for comparisons of morphological characteristics, measurements, morphometric percentages and morphometric ratios commonly used to distinguish species of cyclocoelids. An additional five adult specimens from site #1 were fixed without compression for comparisons. Specimens from site # 1 (n=24) represented only fully-developed, non-senescing adults, while those from site #2 (n=17) could be divided into fully-developed (non-senescing) adults (n=8); younger (smaller, less developed) adults (n=5) and senescing adults (n=4). The following characteristics were relatively consistent, and appeared to be valuable in identifying groups of similar species and distinguishing species in Uvitellina: the presence or absence of the oral sucker; the oral sucker/pharynx width ratio; the posterior extent of the cirrus sac relative to the intestinal bifurcation; the position of the genital pore relative to the pharynx; the position of the testes in the body; the length of the intertesticular space; the length of the posttesticular space; the lateral disposition of the uterine loops; the presence of a posteriorly-directed, tail-like extension off the posterior confluence of the vitelline fields; the posterior extent of the uterine loops relative to the gonads; and the size of fully-developed eggs. It may be beneficial to calculate the percentage that measurements represent relative to the body length to provide insight into the relationship of the size of a structure to increased size of the specimens (growth). Specimens fixed without compression appeared to be less uniform, less symmetrical, shorter, more distorted and the internal details were more difficult to see.
Determination of a Central Avascular Triangle within the Obturator Foramen: A Radioanatomic Study
Nyangoh Timoh, Krystel; Bader, Georges; Fauconnier, Arnaud; Barrau, Vincent; Delmas, Vincent; Touboul, Cyril
2015-01-01
Purpose To map the vascular anatomy of the obturator foramen using fixed anatomic landmarks. Method Twenty obturator regions were dissected in 10 fresh female cadavers after vascular blue dye injection in five cadavers (50%). Furthermore, 104 obturator regions were reconstructed by angiotomodensitometry from 52 women under investigation for suspected arterial disease. The anatomy of the obturator region was mapped by measuring the distance of vascular structures from the middle of the two branches of the ischiopubic bone, which were used as fixed landmarks. Results The bifurcation of the obturator artery was at a mean (SD) distance of 30.0 mm (4.5) from the middle of the ischiopubic branch (MISP). The anterior branch of the obturator vessels was 15.2 mm (10.1) from the MISP. The posterior branch of the obturator vessels was 5.5 mm (4.0) and 23.6 mm (8.7) from the middle of the outer edge of the obturator foramen (MOE) and the MISP, respectively. Using 5° and 95° percentiles of these measurements we defined a central avascular triangle. Conclusions Our data show that, beyond inter-individual variations, a central triangular avascular area can be identified in the obturator foramen between the posterior and anterior obturator artery using fixed landmarks. PMID:26624993
Mobile-bearing knees reduce rotational asymmetric wear.
Ho, Fang-Yuan; Ma, Hon-Ming; Liau, Jiann-Jong; Yeh, Chuan-Ren; Huang, Chun-Hsiung
2007-09-01
Polyethylene wear of bearing components is the most common long-term complication in total knee arthroplasty. One would anticipate differing kinematics would generate different wear patterns (including wear type, degree, and symmetry) on the articulating surface of mobile-bearing and fixed-bearing inserts. Because mobile-bearing designs facilitate movement of the insert relative to the tray when the knee rotates, we hypothesized mobile-bearing designs would reduce the incidence of rotational asymmetric wear. We examined 51 worn tibial inserts, including 15 from mobile-bearing rotating-platform posterior-cruciate-sacrificing dished prostheses and 36 from fixed-bearing posterior-cruciate-retaining flat prostheses, which were retrieved at revision surgery with an average implantation time of 115 months. We divided wear types into low-grade wear (burnishing, abrasion, and cold flow) and high-grade wear (scratching, pitting, metal embedding, and delamination) to assess wear degree of polyethylene. To assess symmetry of wear, the insert surface was divided into medial and lateral sides and each side was further divided into three equal zones along the anteroposterior direction. Low-grade wear was more common in mobile-bearing knees, whereas high-grade wear was more common in fixed-bearing knees. We identified no internal/external rotational asymmetric wear or anteroposterior asymmetric wear in mobile-bearing knees.
Classification framework for partially observed dynamical systems
NASA Astrophysics Data System (ADS)
Shen, Yuan; Tino, Peter; Tsaneva-Atanasova, Krasimira
2017-04-01
We present a general framework for classifying partially observed dynamical systems based on the idea of learning in the model space. In contrast to the existing approaches using point estimates of model parameters to represent individual data items, we employ posterior distributions over model parameters, thus taking into account in a principled manner the uncertainty due to both the generative (observational and/or dynamic noise) and observation (sampling in time) processes. We evaluate the framework on two test beds: a biological pathway model and a stochastic double-well system. Crucially, we show that the classification performance is not impaired when the model structure used for inferring posterior distributions is much more simple than the observation-generating model structure, provided the reduced-complexity inferential model structure captures the essential characteristics needed for the given classification task.
Cautious surgery for discoid menisci
NASA Astrophysics Data System (ADS)
Smith, Chadwick F.; Van Dyk, Eda; Jurgutis, John; Vangsness, C. Thomas
1995-05-01
Thirty patients were surgically treated for discoid menisci at our institution from 1972 to 1987. All developed Fairbank's changes if followed more than 5 years. Between 1980 and 1987 we saw 25 patients with menisci over 50% of the size of the femoral condyle by magnetic resonance imaging or arthrographic examination. Surgical criteria have been anteroposterior hypermobility and arthroscopic evidence of rupture in patients with disabling symptoms. Of the 21 patients undergoing surgery since 1980, 99 (43%) have developed Fairbank's changes, all having been treated by partial meniscectomy or meniscectomy plus posterior repair. Follow-up arthroscopy in five patients revealed distinctly abnormal but relatively stable menisci. Partial meniscectomy for discoid menisci by the Watanabe classification is recommended if symptoms are disabling and the menisci is significantly torn. Repair must be added if the posterior horn is unstable.
Squalius namak, a new chub from Lake Namak basin in Iran (Teleostei: Cyprinidae).
Khaefi, Roozbehan; Esmaeili, Hamid Reza; Sayyadzadeh, Golnaz; Geiger, Matthias F; Freyhof, Jörg
2016-09-19
Squalius namak, new species, from the endorheic Lake Namak and Kavir basins in Iran, is distinguished from the species of the genus Squalius in the Persian Gulf and the southern Caspian Sea basins by having a wide and thick symphysial knob on the lower jaw, a convex posterior anal-fin margin, a bold, dark-grey or brown, roundish or crescent-shaped blotch at the posterior tip of each flank scale and orange caudal-, anal- and pelvic-fin rays in life. Squalius namak is also characterized by four fixed, diagnostic nucleotide substitutions in the mtDNA COI barcode region.
Kiudelis, Mindaugas; Sakalys, Egidijus; Jonaitis, Laimas; Mickevicius, Antanas; Endzinas, Zilvinas
2017-01-01
Introduction Two types of partial wrap are commonly performed in achalasia patients after Heller myotomy: the posterior 270° fundoplication (Toupet) and the anterior 180° fundoplication (Dor). The optimal type of fundoplication (posterior vs. anterior) is still debated. Aim To compare the long-term rates of dysphagia, reflux symptoms and patient satisfaction with current postoperative condition between two fundoplication groups in achalasia treatment. Material and methods Our retrospective study included 97 consecutive patients with achalasia: 37 patients underwent laparoscopic posterior Toupet (270°) fundoplication followed by Heller myotomy (group I); 60 patients underwent laparoscopic anterior partial Dor fundoplication followed by Heller myotomy (group II). Long-term follow-up results included evaluation of dysphagia symptoms, intensity of heartburn and patient satisfaction with current condition. Results Patients in these two groups did not differ according to age, weight, height, postoperative stay or follow-up period. Laparoscopic myotomy with posterior Toupet fundoplication was effective in 89% of patients, while laparoscopic myotomy with anterior Dor was effective in 93% of patients (p > 0.05). 11% of patients after posterior Toupet fundoplication had clinically significant heartburn vs. 35% of patients after anterior Dor fundoplication (p < 0.05). Overall patient satisfaction with current condition was 88%, with no significant difference between the groups. Conclusions According to our study results, the two laparoscopic techniques were similarly effective in reducing achalasia symptoms, but postoperative clinical manifestation of heartburn is significantly more frequent after anterior Dor fundoplication (35% vs. 11%). The majority of patients (88%) were satisfied with operation outcomes. PMID:29062443
Kang, Kyoung-Tak; Koh, Yong-Gon; Son, Juhyun; Kwon, Oh-Ryong; Lee, Jun-Sang; Kwon, Sae Kwang
2017-01-01
This study aimed to determine the biomechanical effect of the posterior condylar offset (PCO) and posterior tibial slope (PTS) in posterior-stabilized (PS) fixed-bearing total knee arthroplasty (TKA). We developed ±1, ±2, and ±3 mm PCO models in the posterior direction and -3°, 0°, 3°, and 6° PTS models using a previously validated FE model. The influence of changes in the PCO and PTS on the biomechanical effects under deep-knee-bend loading was investigated. The contact stress on the PE insert increased by 14% and decreased by 7% on average as the PCO increased and decreased, respectively, compared to the neutral position. In addition, the contact stress on post in PE insert increased by 18% on average as PTS increased from -3° to 6°. However, the contact stress on the patellar button decreased by 11% on average as PTS increased from -3° to 6° in all different PCO cases. The quadriceps force decreased by 14% as PTS increased from -3° to 6° in all PCO models. The same trend was found in patellar tendon force. Changes in PCO had adverse biomechanical effects whereas PTS increase had positive biomechanical effects. However, excessive PTS should be avoided to prevent knee instability and subsequent failure.
Is scale-invariance in gauge-Yukawa systems compatible with the graviton?
NASA Astrophysics Data System (ADS)
Christiansen, Nicolai; Eichhorn, Astrid; Held, Aaron
2017-10-01
We explore whether perturbative interacting fixed points in matter systems can persist under the impact of quantum gravity. We first focus on semisimple gauge theories and show that the leading order gravity contribution evaluated within the functional Renormalization Group framework preserves the perturbative fixed-point structure in these models discovered in [J. K. Esbensen, T. A. Ryttov, and F. Sannino, Phys. Rev. D 93, 045009 (2016)., 10.1103/PhysRevD.93.045009]. We highlight that the quantum-gravity contribution alters the scaling dimension of the gauge coupling, such that the system exhibits an effective dimensional reduction. We secondly explore the effect of metric fluctuations on asymptotically safe gauge-Yukawa systems which feature an asymptotically safe fixed point [D. F. Litim and F. Sannino, J. High Energy Phys. 12 (2014) 178., 10.1007/JHEP12(2014)178]. The same effective dimensional reduction that takes effect in pure gauge theories also impacts gauge-Yukawa systems. There, it appears to lead to a split of the degenerate free fixed point into an interacting infrared attractive fixed point and a partially ultraviolet attractive free fixed point. The quantum-gravity induced infrared fixed point moves towards the asymptotically safe fixed point of the matter system, and annihilates it at a critical value of the gravity coupling. Even after that fixed-point annihilation, graviton effects leave behind new partially interacting fixed points for the matter sector.
Hirata, Kimiko; Yoshimura, Michio; Mukumoto, Nobutaka; Nakamura, Mitsuhiro; Inoue, Minoru; Sasaki, Makoto; Fujimoto, Takahiro; Yano, Shinsuke; Nakata, Manabu; Mizowaki, Takashi; Hiraoka, Masahiro
2017-07-01
We evaluated three-dimensional intrafractional target motion, divided into respiratory-induced motion and baseline drift, in accelerated partial breast irradiation (APBI). Paired fluoroscopic images were acquired simultaneously using orthogonal kV X-ray imaging systems at pre- and post-treatment for 23 patients who underwent APBI with external beam radiotherapy. The internal target motion was calculated from the surgical clips placed around the tumour cavity. The peak-to-peak respiratory-induced motions ranged from 0.6 to 1.5mm in all directions. A systematic baseline drift of 1.5mm towards the posterior direction and a random baseline drift of 0.3mm in the lateral-medial and cranial-caudal directions were observed. The baseline for an outer tumour cavity drifted towards the lateral and posterior directions, and that for an upper tumour cavity drifted towards the cranial direction. Moderate correlations were observed between the posterior baseline drift and the patients' physical characteristics. The posterior margin for intrafractional uncertainties was larger than 5mm in patients with greater fat thickness due to the baseline drift. The magnitude of the intrafractional motion was not uniform according to the direction, patients' physical characteristics, or tumour cavity location due to the baseline drift. Therefore, the intrafractional systematic movement should be properly managed. Copyright © 2017 Elsevier B.V. All rights reserved.
Oh, Joo Han; McGarry, Michelle H; Jun, Bong Jae; Gupta, Akash; Chung, Kyung Chil; Hwang, James; Lee, Thay Q
2012-11-01
Complete repair in massive rotator cuff tear may not be possible, allowing for only partial repair. However, the effect of partial repair on glenohumeral biomechanics has not been evaluated. Therefore, the purpose of this study was to compare the rotational range of motion (ROM), glenohumeral kinematics, and gap formation at the repaired tendon edge following massive cuff tear and repair according to the degree of repair completion. Posterior fixation will restore the altered biomechanics of massive rotator cuff tear. Controlled laboratory study. Eight cadaveric shoulders were tested at 0°, 30°, and 60° of abduction in the scapular plane. Muscle loading was applied based on physiological muscle cross-sectional area ratios. Maximum internal (MaxIR) and external rotations (MaxER) were measured. Humeral head apex (HHA) position and gap formation at the repaired tendon edge were measured using a MicroScribe from MaxIR to MaxER in 30° increments. Testing was performed for intact, massive cuff tear, complete repair, and 4 types of partial repair. A repeated-measures analysis of variance was used to determine significant differences. Massive tear significantly increased ROM and shifted HHA superiorly in MaxIR at all abduction angles (P < .05). The complete repair restored ROM to intact (P < .05), while all partial repairs did not. Abnormal HHA elevation due to massive tear was restored by all repairs (P < .05). Release of the anterior single row alone and release of the marginal convergence significantly increased gap formation at the anterior tendon edge (P < .05). This study emphasizes the importance of anterior fixation in massive cuff tear to restore rotational range of motion and decrease gap formation at the repaired tendon edge and of posterior fixation to restore abnormal glenohumeral kinematics due to massive cuff tear. If complete repair of massive cuff tear is not possible, posterior cuff (infraspinatus) repair is necessary to restore abnormal glenohumeral kinematics, and margin convergence anteriorly is recommended to decrease gap formation of the repaired tendon edge, which may provide a better biomechanical environment for healing.
Precise Point Positioning with Partial Ambiguity Fixing.
Li, Pan; Zhang, Xiaohong
2015-06-10
Reliable and rapid ambiguity resolution (AR) is the key to fast precise point positioning (PPP). We propose a modified partial ambiguity resolution (PAR) method, in which an elevation and standard deviation criterion are first used to remove the low-precision ambiguity estimates for AR. Subsequently the success rate and ratio-test are simultaneously used in an iterative process to increase the possibility of finding a subset of decorrelated ambiguities which can be fixed with high confidence. One can apply the proposed PAR method to try to achieve an ambiguity-fixed solution when full ambiguity resolution (FAR) fails. We validate this method using data from 450 stations during DOY 021 to 027, 2012. Results demonstrate the proposed PAR method can significantly shorten the time to first fix (TTFF) and increase the fixing rate. Compared with FAR, the average TTFF for PAR is reduced by 14.9% for static PPP and 15.1% for kinematic PPP. Besides, using the PAR method, the average fixing rate can be increased from 83.5% to 98.2% for static PPP, from 80.1% to 95.2% for kinematic PPP respectively. Kinematic PPP accuracy with PAR can also be significantly improved, compared to that with FAR, due to a higher fixing rate.
Precise Point Positioning with Partial Ambiguity Fixing
Li, Pan; Zhang, Xiaohong
2015-01-01
Reliable and rapid ambiguity resolution (AR) is the key to fast precise point positioning (PPP). We propose a modified partial ambiguity resolution (PAR) method, in which an elevation and standard deviation criterion are first used to remove the low-precision ambiguity estimates for AR. Subsequently the success rate and ratio-test are simultaneously used in an iterative process to increase the possibility of finding a subset of decorrelated ambiguities which can be fixed with high confidence. One can apply the proposed PAR method to try to achieve an ambiguity-fixed solution when full ambiguity resolution (FAR) fails. We validate this method using data from 450 stations during DOY 021 to 027, 2012. Results demonstrate the proposed PAR method can significantly shorten the time to first fix (TTFF) and increase the fixing rate. Compared with FAR, the average TTFF for PAR is reduced by 14.9% for static PPP and 15.1% for kinematic PPP. Besides, using the PAR method, the average fixing rate can be increased from 83.5% to 98.2% for static PPP, from 80.1% to 95.2% for kinematic PPP respectively. Kinematic PPP accuracy with PAR can also be significantly improved, compared to that with FAR, due to a higher fixing rate. PMID:26067196
NASA Astrophysics Data System (ADS)
Zhang, Wei-Guo; Li, Zhe; Liu, Yong-Jun
2018-01-01
In this paper, we study the pricing problem of the continuously monitored fixed and floating strike geometric Asian power options in a mixed fractional Brownian motion environment. First, we derive both closed-form solutions and mixed fractional partial differential equations for fixed and floating strike geometric Asian power options based on delta-hedging strategy and partial differential equation method. Second, we present the lower and upper bounds of the prices of fixed and floating strike geometric Asian power options under the assumption that both risk-free interest rate and volatility are interval numbers. Finally, numerical studies are performed to illustrate the performance of our proposed pricing model.
Castillo-Oyagüe, Raquel; Sancho-Esper, Rocío; Lynch, Christopher D; Suárez-García, María-Jesús
2018-01-01
To evaluate the current status of all-ceramic inlay-retained fixed dental prostheses (CIR-FDPs) for the replacement of posterior teeth. Screening of titles and abstracts, full-text analysis for inclusion eligibility, quality assessment, data extraction and evaluation of the scientific evidence were performed independently by two reviewers. The electronic databases MEDLINE/PubMed, EMBASE, Cochrane Central Register of Controlled Trials, and Compludoc were searched with no restriction to publication date or language. The quality of the studies was evaluated through: the original 'QDP' ('Questionnaire for selecting articles on Dental Prostheses') (for research papers); the 'Guidelines for managing overviews' of the Evidence-Based Medicine Working Group (for reviews); the Cochrane risk of bias tool; and the GRADE scale for grading scientific evidence. This review started with 4942 articles, which were narrowed down to 23 according to the selection criteria. The data was not statistically treated because of the heterogeneity of the studies. Zirconia-based CIR-FDPs may be recommended for restoring posterior single missing teeth, although the prosthesis/tooth bonded interface has yet to be improved. The addition of lateral wings to the classical inlay preparation seems promising. The weakest parts of CIR-FDPs are the connectors and retainers, while caries and endodontic problems are the most common biological complications. The fabrication of CIR-FDPs with monolithic zirconia may eliminate chipping problems. A three-unit CIR-FDP is a viable treatment option for replacing a posterior missing tooth. Appropriate case selection, abutment preparation and luting procedures may be decisive for clinical success. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Generalized contractive mappings and weakly α-admissible pairs in G-metric spaces.
Hussain, N; Parvaneh, V; Hoseini Ghoncheh, S J
2014-01-01
The aim of this paper is to present some coincidence and common fixed point results for generalized (ψ, φ)-contractive mappings using partially weakly G-α-admissibility in the setup of G-metric space. As an application of our results, periodic points of weakly contractive mappings are obtained. We also derive certain new coincidence point and common fixed point theorems in partially ordered G-metric spaces. Moreover, some examples are provided here to illustrate the usability of the obtained results.
Generalized Contractive Mappings and Weakly α-Admissible Pairs in G-Metric Spaces
Hussain, N.; Parvaneh, V.; Hoseini Ghoncheh, S. J.
2014-01-01
The aim of this paper is to present some coincidence and common fixed point results for generalized (ψ, φ)-contractive mappings using partially weakly G-α-admissibility in the setup of G-metric space. As an application of our results, periodic points of weakly contractive mappings are obtained. We also derive certain new coincidence point and common fixed point theorems in partially ordered G-metric spaces. Moreover, some examples are provided here to illustrate the usability of the obtained results. PMID:25202742
dos Santos Nunes Reis, José Maurício; da Cruz Perez, Luciano Elias; Alfenas, Bruna Fernandes Moreira; de Oliveira Abi-Rached, Filipe; Filho, João Neudenir Arioli
2014-01-01
Despite requiring dental crown preparation and possible root canal treatment, besides the difficulty of clinical and laboratory repairs, and financial burden, the association between fixed (FPD) and removable partial dentures (RPD) by means of attachments is an important alternative for oral rehabilitation, particularly when the use of dental implants and FPDs is limited or not indicated. Among the advantages of attachment-retained RPDs are the improvements in esthetics and biomechanics, as well as correction of the buccal arrangement of anterior teeth in Kennedy Class III partially edentulous arches. This article describes the treatment sequence and technique for the use of attachments in therapy combining FPD/RPD. © 2013 by the American College of Prosthodontists.
Kumari, Lalima; Nayan, Kamal
2016-12-01
A 16-year-old female patient with skeletal Class III malocclusion and bilateral posterior cross bite complaining of difficulty in chewing was treated orthodontically without surgery (camouflage treatment). The treatment comprised of fixed orthodontic treatment with MBT prescription (0.022˝×0.028˝ slot) using quad helix appliance for bilateral expansion of maxillary arch and Class III elastics for occlusal correction. Post-treatment records showed normal overbite and overjet with acceptable occlusion. So with this treatment strategy of expanding the maxillary arch using a quad helix appliance and use of Class III elastics, we achieved a good result with optimal occlusion.
Udani, Vikram; Holly, Langston T; Chow, Daniel; Batzdorf, Ulrich
2014-01-01
We describe our use of a perforated titanium plate to perform a partial posterior fossa cranioplasty in the treatment of cerebellar ptosis and dural ectasia after posterior fossa decompression (PFD). Twelve patients who had undergone PFD underwent posterior fossa reconstruction using a titanium plate. Symptoms were related to either descent of the cerebellum into the decompression or to dural ectasia into the craniectomy defect. Twelve patients who had undergone large suboccipital craniectomies and who presented with persistent headaches and some with neurological symptoms related to syringomyelia, underwent reoperation with placement of a small titanium plate. Ten of 12 patients showed symptomatic improvement after reoperation. Placement of a titanium plate appears to be an effective method of treatment of cerebellar ptosis and dural ectasia after PFD for Chiari malformation. Copyright © 2014 Elsevier Inc. All rights reserved.
Tehranzadeh, Arash D; Fronek, Jan; Resnick, Donald
2007-01-01
In the high-performance athlete, acquired thickening of the posterior joint capsule is a proposed etiology for glenohumeral internal rotational deficit (GIRD). The purpose of this study was to present our MR arthrographic imaging observations of posterior capsular thickening in professional baseball players who present with reduced throwing velocity related to pain and clinical findings of internal rotational deficit of the glenohumeral joint. Our observations of MR imaging features in patients with clinical and arthroscopic manifestations of GIRD lesions include articular surface partial thickness tears of the supraspinatus and infraspinatus tendons, superoposterior subluxation of the humeral head and SLAP tears of the labrum. Although no empiric standard currently exists for the axial dimension thickness of the shoulder capsule, we have observed a thickened appearance of the posterior band of the inferior glenohumeral ligament in these patients.
Posterior medial meniscus detachment: a unique type of medial meniscal tear.
Rubinstein, Richard A; DeHaan, Alex; Baldwin, James L
2009-10-01
Patients with posterior medial meniscal detachment, as determined at knee arthroscopy, were evaluated retrospectively. Mean follow-up was 5.3 years for 8 men and 20 women (30 knees; mean age, 57 years). Most patients had acute onset of pain with a minor specific incident. Seventeen patients were obese, 9 were overweight, and 2 were normal. Eleven of 22 magnetic resonance imaging evaluations detected a tear at the site of the posterior medial meniscus root. Nine of 16 bone scan evaluations showed moderate uptake medially. Arthroscopic treatment included partial medial meniscectomy or meniscal repair. Twelve knees (40%) showed significant progression of arthritis. Of the 7 patients with severe arthritic knees, 5 have subsequently undergone total knee arthroplasty, 1 is considering total knee arthroplasty, and the other has minimal symptoms. Patients should be counseled about the clinical course of posterior medial meniscus detachment and its potential for progressive arthritis in the joint.
Castillo-Oyagüe, Raquel; Perea, Carmen; Suárez-García, María-Jesús; Río, Jaime Del; Lynch, Christopher D; Preciado, Arelis
2016-12-01
To validate the 'Quality of Life related to function, aesthetics, socialization, and thoughts about health-behavioural habits (QoLFAST-10)' questionnaire for assessing the whole concept of oral health-related quality of life (OHRQoL) of implant-supported fixed partial denture (FPD) wearers. 107 patients were assigned to: Group 1 (HP; n=37): fixed-detachable hybrid prostheses (control); Group 2 (C-PD, n=35): cemented partial dentures; and Group 3 (S-PD, n=35): screwed partial dentures. Patients answered the QoLFAST-10 and the Oral Health Impact Profile (OHIP-14sp) scales. Information on global oral satisfaction, socio-demographic, prosthetic, and clinical data was gathered. The psychometric capacity of the QoLFAST-10 was investigated. The correlations between both indices were explored by the Spearman's rank test. The effect of the study variables on the OHRQoL was evaluated by descriptive and non-parametric probes (α=0.05). The QoLFAST-10 was reliable and valid for implant-supported FPD wearers, who attained comparable results regardless of the connection system being cement or screws. Both fixed partial groups demonstrated significantly better social, functional, and total satisfaction than did HP wearers with this index. All groups revealed similar aesthetic-related well-being and consciousness about the importance of health-behavioural habits. Several study variables modulated the QoLFAST-10 scores. Hybrid prostheses represent the least predictable treatment option, while cemented and screwed FPDs supplied equal OHRQoL as estimated by the QoLFAST-10 scale. The selection of cemented or screwed FPDs should mainly rely on clinical factors, since no differences in patient satisfaction may be expected between both types of implant rehabilitations. Copyright © 2016 Elsevier Ltd. All rights reserved.
ĎuriŠ, ZdenĚk
2018-03-22
Madeirasquilla tuerkayi is described as a new genus and species of the nannosquillid mantis shrimps (Stomatopoda) based on a single specimen collected from Madeira, eastern Atlantic. That specimen is remarkable by a combination of the following morphological characters: rostral plate with three sharp anterior projections; antennal protopod with two mesial and one ventral papillae; cornea subglobular; raptorial claw dactylus with 11 or 12 teeth, and with acute proximal tooth on outer margin; pleonite 6 with strong posterolateral spine and two posteriorly directed sternal spines; telson bearing smooth shield-like dorsal prominence with acute median spine posteriorly; four pairs of fixed primary teeth posteriorly on the telson; outer primary spine of uropodal protopod longer than inner primary spine. The separate position of the new genus is supported also by molecular comparison. A key to the genera of the family Nannosquillidae is proposed.
Nascimento, Jeane Marcelle Cavalcante Do; Hamada, Neusa; Andrade-Souza, Vanderly; Adler, Peter H
2018-01-10
The black fly Simulium (Trichodagmia) hirtipupa Lutz (Diptera: Simuliidae) is widely distributed in southern Brazil, with one report from Amapá state in the northern region of Brazilian Amazonia. Morphological comparison of northern and southern populations revealed differences in all life stages, corroborated by chromosomal and molecular analyses, and indicated that the population previously identified as S. hirtipupa from Amapá state represents an undescribed species. This new species is described based on all life stages above the egg, and its chromosomal and molecular divergence from S. hirtipupa is highlighted. Simulium criniferum n. sp. can be diagnosed by the deeply concave male ventral plate with a prominent median projection bearing a ventral keel; female anal lobe in lateral view with a broadly rounded, distal membranous area about as long as wide; pupa with a boot-shaped cocoon bearing a minutely bubbled surface, cephalic plate and thorax with abundant hair-like tubercles, and gill of 12 translucent filaments with darkly sclerotized, acuminate tips; and larva with the body cuticle bearing spiniform setae, abdomen truncated posteriorly, and gill histoblast in situ with the filament tips directed ventrally. Chromosomally, the new species has five unique fixed inversions and uniquely shares three additional fixed inversions with its nearest relative, S. hirtipupa. Partial COI sequences indicate a genetic distance of ~9% between the new species and S. hirtipupa. Females of the new species are anthropophilic. © The Author(s) 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Sailer, Irena; Balmer, Marc; Hüsler, Jürg; Hämmerle, Christoph Hans Franz; Känel, Sarah; Thoma, Daniel Stefan
The aim of this study was to test whether posterior zirconia-ceramic (ZC) and metal-ceramic (MC) fixed dental prostheses (FDPs) exhibit similar survival and technical/biologic complication rates. A total of 58 patients in need of 76 posterior FDPs were randomly assigned to receive 40 ZC and 36 MC FDPs. The restorations were examined at baseline (cementation) and yearly for 5 years. Technical and biologic outcomes were compared. The independent treatment groups were compared with nonparametric Mann-Whitney test for metric variables and with Fisher exact test for categoric data. A total of 52 patients with 40 ZC and 29 MC FDPs were examined at 5 years. No FDP failed during the 5 years; 2 ZC FDPs failed at 65.4 and 73.3 months. Debonding occurred at 3 ZC FDPs. Technical outcomes (modified US Public Health Service criteria) and general periodontal parameters did not show significant differences between ZC and MC FDPs. ZC FDPs exhibited similar outcomes to MC FDPs based on 5-year survival estimates. The majority of technical and biologic outcome measures were not significantly different.
Treatment planning: implant-supported partial overdentures.
Chee, Winston W L
2005-04-01
When multiple anterior teeth are missing, many options of replacement are available. Traditionally, the choice was between a fixed or removable prostheses. Today, with the predictability of dental implants, the options of tooth replacement range from removable partial dentures to implant-supported fixed prostheses. The choice of which restoration that will best provide occlusion and esthetics depends on multiple factors including the number and location of missing teeth, the residual ridge form in relation to the replacement teeth, the relationship of the maxillary and mandibular anterior teeth, the condition of teeth adjacent to the edentulous span, the amount of bone available for implant placement, the patients "smile line" and display of teeth, lip support, and financial constraints. When there is minimal loss of the ridge contour, restorations that emerge from the ridge are the most functional and esthetic restorations, adhesive-type fixed partial dentures, conventional fixed partial dentures, and implant-supported restorations can be indicated with the choice of restoration dependent on a risk benefit and cost benefit analysis. When there is a loss of ridge contour due to residual ridge resorption or trauma, the decision becomes more complex as not only does the tooth structure need to be replaced, the ridge form also has to be replaced. (Figures 1 and 2). This can be assessed clinically as illustrated by Figures 1 and 2 where a dis crepancy in arch form and ridge form in relation to the adjacent teeth and/or opposing arch can be observed. Other considerations are lip support and display of the teeth when smiling. This article presents a case and rationale for implant-supported par tial overdentures. Many authors have written on the merits of com plete overdentures. The complete overdenture has proven to be an improvement over conventional complete prostheses with respect to chewing efficiency, patient comfort and satisfaction. In partial edentulism, the implant-supported overdenture has several advantages, some in common with a removable partial denture.
Precision attachments for the partially dentate mouth
Preiskel, H W
1974-01-01
Some uses of precision attachments in restoring the partially dentate mouth are considered. These devices are indicated where neither the clasp-retained denture nor the fixed bridge is entirely suitable. ImagesFig. 2 PMID:4614689
Usuelli, Federico G; Manzi, Luigi; Brusaferri, Giovanni; Neher, Robert E; Guelfi, Matteo; Maccario, Camilla
2017-06-01
Sagittal implant malalignment after total ankle replacement (TAR) has been considered to be a possible cause for premature implant failure. In a prior study, the change over time of the tibiotalar ratio (T-T ratio), which is the ratio between the posterior longitudinal talar length and the full longitudinal talar length, was assessed in 66 TARs where an unconstrained, mobile-bearing implant was implanted. The analysis documented an increase in the T-T ratio between 2 and 6 months post-surgery (on average from 34.6% to 37.2%). We hypothesized that this change might have been related to the presence of a mobile-bearing insert. In order to test our hypothesis, we designed a study to compare the translation of the talus in TARs performed with an unconstrained, mobile-bearing implant (designated the "Mobile ankle") and those performed with a semi-constrained, fixed-bearing implant (designated the "Fixed ankle"). The study included 71 consecutive patients (71 ankles) who underwent TAR with the Mobile ankle and 24 consecutive patients (24 ankles) who received the Fixed ankle from May 2011 to December 2014. Patients were assessed clinically and radiologically preoperatively (T 0 ), at 6 months (T 2 ) and 12 months (T 3 ) post-surgery. There was also a radiological assessment at 2 months post-surgery (T 1 ). The comparison of the T-T ratio between the two implant groups and over time indicated an interaction between time and group, therefore the changes of the T-T ratio over time were affected by the implant type factor (P<0.001). The changes of the postoperative T-T ratio over time were not significant in the Fixed ankle group (35.7±6.7% at T 1 , T 2 , and T 3 ; P=1.0 for each pairwise comparison). In the Mobile ankle group, the T-T ratio at 2 months (34.4±5.5%) was significantly different to the T-T ratio at 6 months (37.0±5.8%; P<0.001; i.e. there was a significant posterior translation of the talus). The AOFAS score increased from preop to 12 months post-surgery in both the Mobile ankle (72.7±12.8 at 12 months; P<0.001) and the Fixed ankle (85.0±9.7 at 12 months; P<0.001). The significant posterior translation of the talus from 2 to 6 months documented only in the Mobile ankle group may have been associated with the presence of the mobile bearing interface. Copyright © 2016 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Ostman, Pär-Olov; Wennerberg, Ann; Albrektsson, Tomas
2010-03-01
Recently, a new implant surface texture, featuring application of nanometer-scale calcium phosphate has been shown to enhance early bone fixation and formation in preclinical studies and in human histomorphometric studies, which may be beneficial in immediate loading situations. The purpose of the present prospective clinical study was to, during 1 year, clinically and radiographically evaluate a nanometer scale surface modified implant placed for immediate loading of fixed prostheses in both maxillary and mandibular regions. Thirty-five out of 38 patients who needed implant treatment and met inclusion criteria agreed to participate in the study and were consecutively enrolled. Surgical implant placement requirements consisted of a final torque of a least 25 Ncm prior to final seating and an implant stability quotient above 55. A total of 102 NanoTite PREVAIL (NTP) implants (BIOMET 3i, Palm Beach Gardens, FL, USA) (66 maxillary and 36 mandibular) were placed by one investigator, and the majority of these were placed in posterior regions (65%) and in soft bone (69%). A total of 44 prosthetic constructions were evaluated consisting of 14 single-tooth restorations, 26 fixed partial dentures, and four complete fixed restorations. All provisional constructions were delivered within 1 hour, and the final constructions placed after 4 months. Implants were monitored for clinical and radiographic outcomes at follow-up examinations scheduled for 3, 6, and 12 months. Of the 102 study implants, one implant failed. The simple cumulative survival rate value at 1 year was 99.2%. The average marginal bone resorption was 0.37 mm (SD 0.39) during the first year in function. According to the success criteria of Albrektsson and Zarb, success grade 1 was found with 93% of the implants. Although limited to the short follow-up, immediate loading of NanoTite Prevail implants seems to be a viable option in implant rehabilitation, at least when a good initial fixation is achieved.
Jin, Hengwei; Liu, Zhan; Chang, Qing; Chen, Chang; Ge, Huijian; Lv, Xianli; Li, Youxiang
2017-10-01
Objective Brainstem arteriovenous malformations (AVMs) are rare lesions with a high risk of intracranial hemorrhage and are challenging to treat. We present our experience of endovascular embolization with Onyx in these aggressive lesions. Materials and methods Between 2007 and 2016, 13 patients with brainstem AVMs were embolized with Onyx at our center. Twelve patients presented with intracranial hemorrhage and one with headache. Retrospective examinations of patient demographics, clinical presentation, angiographic features, treatment modalities, postoperative complications and outcomes were carried out. Results The AVMs were in the midbrain in 10 patients (one anterior and nine posterior or dorsal), in the posterior pons in two and pontomedullary in one. Complete occlusion was achieved in three patients. Gamma knife radiosurgery was performed in six patients who were near-completely or partially embolized. Postoperative complications, including five cases of ischemia and one case of hemorrhage, resulted in four cases of neurological deterioration and two deaths. Clinical follow-up was obtained in 10 patients at a mean period of 45.2 months (range 3 to 93 months). During the follow-up, good clinical outcomes were observed in seven patients with posterior or dorsal midbrain AVMs, and one patient with a posterior pons AVM that was partially occluded died of intracranial hemorrhage. Conclusion Endovascular embolization for brainstem AVM with Onyx is a technical challenge and the reflux of Onyx may cause severe complications. Individualized treatment is needed based on the specific subtype of brainstem AVM.
Zhu, Li-Zhen; Liu, Liang-Le; Cai, Chun-Yuan; Yang, Guo-Jing; Zhang, Li-Cheng; Zhu, Qi
2012-08-01
To explore selection and efficacy assessment for membranous urethral trauma caused by pelvic fracture. From June 2000 to August 2010, 72 patients with membranous urethral trauma caused by pelvic fracture were selected. There were 46 males and 26 females,ranging age from 26 to 62 years (averaged 35.2 years). The time from injury to hospitalization time was 1 to 3 hours. According to Tile pelvic fracture classification, there were 8 patients with type A, 45 patients with type B, 19 patients with type C. Thirty of the 35 patients with partial rupture of posterior urethral were treated by catheterization,5 patients treated by rupture anastomosis on the stage I combined with cystostomy; 25 of the 37 patients with complete rupture of posterior urethra were treated by early realignment, and 12 patients were treated by cystostomy. Urinary incontinence, impotence and urethrostenosis were evaluated. All patients were followed up for 5 to 10 years (mean 7.7 years). Incidence of urethrostenosis, impotence and urinary incontinence in patients treated by cystostomy were significantly higher than rupture anastomosis on the stage I and early realignment (P < 0.05); while incidence in patients treated by catheterization was significantly lower than other groups (P < 0.05). For patients with partial rupture of posterior urethral, catheterization and rupture anastomosis on the stage I are preferred methods; while patients with complete rupture of posterior urethra, early realignment is a preferred method with advantages of simple operation and less complications.
Reactive histiocytosis of the orbit and posterior segment in a dog.
Pumphrey, Stephanie A; Pizzirani, Stefano; Pirie, Christopher G; Sato, Amy F; Buckley, Faith I
2013-05-01
We present a case of reactive histiocytic disease involving the orbit, optic nerve, retina, and choroid in a Border Collie dog initially presenting for vision loss. Long-term partial return of vision has been achieved with systemic immunosuppression. Anterior segment and ocular surface manifestations of reactive histiocytic disease in dogs are relatively common. Posterior segment and orbital involvement, however, are minimally documented in the existing literature. To the authors' knowledge, this is the first report of disease confined to the orbit and posterior segment as well as the first report of vision loss as a presenting complaint for reactive histiocytic disease. Clinical, magnetic resonance imaging, cytologic, and histopathologic findings are reviewed. © 2012 American College of Veterinary Ophthalmologists.
Ruch, David S; Watters, Tyler Steven; Wartinbee, Daniel A; Richard, Marc J; Leversedge, Fraser J; Mithani, Suhail K
2014-08-01
To describe pertinent anatomic findings during repair of chronic, partial distal biceps tendon tears and to compare the complications of surgery with a similar cohort of acute, complete tears. Group 1 included 14 patients (15 elbows) with partial tears managed operatively an average of 10 months from onset of injury or symptoms. Group 2 included a matched cohort of 16 patients (17 elbows) treated for complete, acute tears an average of 19 days from injury. A retrospective review of all 30 patients focused on demographic data, intraoperative findings, and postoperative complications. A single, anterior incision was used in all cases with multiple suture anchors or a bicortical toggling button for fixation of the repair. We evaluated 27 men and 3 women with an average age of 55 years (group 1) and 48 years (group 2). Intratendinous ganglion formation at the site of rupture of the degenerative tendon was observed in 5 cases of partial tears and none of the complete tears. Partial tears involved the lateral aspect or short head of the biceps tendon insertion in all cases. Postoperative complications included lateral antebrachial cutaneous nerve neuritis in 8 group 1 patients and 6 group 2 patients and transient posterior interosseus nerve palsy in 3 group 1 patients. Partial distal biceps tendon ruptures showed a consistent pattern of pathology involving disruption of the lateral side of the tendon insertion involving the small head of the biceps. Degenerative intratendinous ganglion formation was present in one third of cases. Repair of chronic, partial distal biceps tendon injuries may have a higher incidence of posterior interosseous and lateral antebrachial cutaneous nerve palsies. Therapeutic III. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Bounding the Resource Availability of Partially Ordered Events with Constant Resource Impact
NASA Technical Reports Server (NTRS)
Frank, Jeremy
2004-01-01
We compare existing techniques to bound the resource availability of partially ordered events. We first show that, contrary to intuition, two existing techniques, one due to Laborie and one due to Muscettola, are not strictly comparable in terms of the size of the search trees generated under chronological search with a fixed heuristic. We describe a generalization of these techniques called the Flow Balance Constraint to tightly bound the amount of available resource for a set of partially ordered events with piecewise constant resource impact We prove that the new technique generates smaller proof trees under chronological search with a fixed heuristic, at little increase in computational expense. We then show how to construct tighter resource bounds but at increased computational cost.
Anitua, Eduardo; Flores, Carlos; Piñas, Laura; Alkhraisat, Mohammad
2018-06-05
CAD-CAM technology permits the angular correction of screw emergence into the prosthesis, however there is lack of controlled clinical studies that assess the frequency of technical complications in angled screw channel restorations. This controlled clinical study was designed to assess technical incidences in angled screw channel restorations. Patients having implant prosthesis placed between November, 2014 and December, 2015 were screened. The patients were selected if they received prosthesis with up to 30º correction of the prosthesis screw emergence and had at least one non-angulated prosthesis (screw-retained). All the prostheses were located completely/partially in the posterior region. The frequency of technical complications was the principal variable. A total of 52 patients with a mean age of 62 ± 10 years participated with a total 110 prostheses (55 in the test group and 55 in the control group). A total of 11 technical complications occurred (7 in the test group and 4 in the control group). These differences were not statistically significant. All the prostheses in both groups survived the follow-up. The correction of the screw emergence into the prosthesis has not increased the risk of technical complications in CAD-CAM implant prostheses.
Immediate Loading of Tapered Implants Placed in Postextraction Sockets and Healed Sites.
Han, Chang-Hun; Mangano, Francesco; Mortellaro, Carmen; Park, Kwang-Bum
2016-07-01
The aim of the present study was to compare the survival, stability, and complications of immediately loaded implants placed in postextraction sockets and healed sites. Over a 2-year period, all patients presenting with partial or complete edentulism of the maxilla and/or mandible (healed site group, at least 4 months of healing after tooth extraction) or in need of replacement of nonrecoverable failing teeth (postextraction group) were considered for inclusion in this study. Tapered implants featuring a nanostructured calcium-incorporated surface were placed and loaded immediately. The prosthetic restorations comprised single crowns, fixed partial dentures, and fixed full arches. Primary outcomes were implant survival, stability, and complications. Implant stability was assessed at placement and at each follow-up evaluation (1 week, 3 months, and 1 year after placement): implants with an insertion torque (IT) <45 N·cm and/or with an implant stability quotient (ISQ) <70 were considered failed for immediate loading. A statistical analysis was performed. Thirty implants were placed in postextraction sockets of 17 patients, and 32 implants were placed in healed sites of 22 patients. There were no statistically significant differences in ISQ values between the 2 groups, at each assessment. In total, 60 implants (96.8%) had an IT ≥45 and an ISQ ≥70 at placement and at each follow-up control: all these implants were successfully loaded. Only 2 implants (1 in a postextraction socket and 1 in a healed site, 3.2%) could not achieve an IT ≥45 N·cm and/or an ISQ ≥70 at placement or over time: accordingly, these were considered failed for stability, as they could not be subjected to immediate loading. One of these 2 implants, in a healed site of a posterior maxilla, had to be removed, yielding an overall 1-year implant survival rate of 98.4%. No complications were reported. No significant differences were reported between the 2 groups with respect to implant failures and complications. Immediately loaded implants placed in postextraction sockets and healed sites had similar high survival and stability, with no reported complications. Further long-term studies on larger samples of patients are needed to confirm these results.
Gao, Shu-Guang; Zhang, Can; Zhao, Rui-Bo; Liao, Zhan; Li, Yu-Sheng; Yu, Fang; Zeng, Chao; Luo, Wei; Li, Kang-Hua; Lei, Guang-Hua
2013-09-01
The relationship between medial meniscus tear and posterior cruciate ligament (PCL) injury has not been exactly explained. We studied to investigate the biomechanical effect of partial and complete PCL transection on different parts of medial meniscus at different flexion angles under static loading conditions. TWELVE FRESH HUMAN CADAVERIC KNEE SPECIMENS WERE DIVIDED INTO FOUR GROUPS: PCL intact (PCL-I), anterolateral bundle transection (ALB-T), posteromedial bundle transection (PMB-T) and PCL complete transection (PCL-T) group. Strain on the anterior horn, body part and posterior horn of medial meniscus were measured under different axial compressive tibial loads (200-800 N) at 0°, 30°, 60° and 90° knee flexion in each groups respectively. Compared with the PCL-I group, the PCL-T group had a higher strain on whole medial meniscus at 30°, 60° and 90° flexion in all loading conditions and at 0° flexion with 400, 600 and 800 N loads. In ALB-T group, strain on whole meniscus increased at 30°, 60° and 90° flexion under all loading conditions and at 0° flexion with 800 N only. PMB-T exihibited higher strain at 0° flexion with 400 N, 600 N and 800 N, while at 30° and 60° flexion with 800 N and at 90° flexion under all loading conditions. Partial PCL transection triggers strain concentration on medial meniscus and the effect is more pronounced with higher loading conditions at higher flexion angles.
Mulligan, Ryan P; Adams, Samuel B; Easley, Mark E; DeOrio, James K; Nunley, James A
2017-12-01
A variety of operative approaches and fixation techniques have been described for tibiotalocalcaneal (TTC) arthrodesis. The intramedullary (IM) nail and lateral, fixed-angle plating are commonly used because of ease of use and favorable biomechanical properties. A lateral, transfibular (LTF) approach allows for direct access to the tibiotalar and subtalar joints, but the posterior, Achilles tendon-splitting (PATS) approach offers a robust soft tissue envelope. The purpose of this study was to compare the results of TTC arthrodesis with either a PATS approach with IM nailing or LTF approach with fixed-angle plating. A retrospective review was performed on all patients who underwent simultaneous TTC arthrodesis with minimum 1 year clinical and radiographic follow up. Patients were excluded if they underwent TTC arthrodesis through an approach other than PATS or LTF, and received fixation without an IM nail or fixed-angle plate. Primary outcomes examined were union rate, revisions, and complications. Thirty-eight patients underwent TTC arthrodesis with a PATS approach and IM nailing, and 28 with a LTF approach and lateral plating. The overall union rate was 71%; 76% (29 of 38 patients) for the PATS/IM nail group, and 64% (18 of 28) for LTF/plating group ( P = .41). Symptomatic nonunion requiring revision arthrodesis occurred in 16% (6 of 38) of the PATS/IM nail group versus 7% (2 of 28) in the LTF/lateral plating group ( P = .45). There were no significant differences in individual tibiotalar or subtalar union rates, superficial wound problems, infection, symptomatic hardware, stress fractures, or nerve irritations. Union, revision, and complication rates were similar for TTC arthrodesis performed with a PATS approach and IM nail compared with an LTF approach and fixed-angle plate in a complex patient population. Both techniques were adequate, especially when prior incisions, preexisting hardware, or deformity preclude options. Level III, retrospective comparative study.
Valid randomization-based p-values for partially post hoc subgroup analyses.
Lee, Joseph J; Rubin, Donald B
2015-10-30
By 'partially post-hoc' subgroup analyses, we mean analyses that compare existing data from a randomized experiment-from which a subgroup specification is derived-to new, subgroup-only experimental data. We describe a motivating example in which partially post hoc subgroup analyses instigated statistical debate about a medical device's efficacy. We clarify the source of such analyses' invalidity and then propose a randomization-based approach for generating valid posterior predictive p-values for such partially post hoc subgroups. Lastly, we investigate the approach's operating characteristics in a simple illustrative setting through a series of simulations, showing that it can have desirable properties under both null and alternative hypotheses. Copyright © 2015 John Wiley & Sons, Ltd.
Ma, Polly S; Brudvik, James S
2008-10-01
The treatment modality, a continuous occlusal rest removable partial denture, not only restored missing teeth but also stabilized the remaining dentition in a patient with advanced periodontal attachment loss. By engaging the guiding planes at the mesial surfaces of the abutments anteriorly and also the distal surfaces of the abutments posteriorly, the remaining teeth, with varying amounts of mobility, were splinted together by the framework. This conservative treatment option allows flexibility for easy repair during the life span of the prosthesis.
Sohn, Dong-Seok; Kim, Woo-Sung; Lee, Won-Hyuk; Jung, Heui-Seung; Shin, Im-Hee
2010-10-01
The aim of this retrospective study was to evaluate the survival rate of sintered porous-surfaced implants placed in the edentulous posterior mandibles, in relation to implant length and diameter, crown-to-implant ratio, and types of prostheses, for a maximum of 9 years of functioning (mean: 55.8 months; range: 5-108 months). The study group consisted of 43 partially edentulous patients who visited Catholic University Hospital of Daegu and 1 private dental clinic. A total of 122 sintered porous-surfaced implants--Endopore (Innova Life Sciences, Toronto, Ontario, Canada)--were placed in the edentulous posterior mandibles. Two diameter sizes (4.1 and 5.0 mm) and 4 lengths (5.0, 7.0, 9.0, and 12.0 mm) were used. All implants were restored with fixed prostheses. One hundred three implants were splinted and 21 implants were nonsplinted. Panoramic views and periapical radiographs were taken at the time of the first, postoperative, crown placement, and following checkup visits. The survival rates of the implants in relation to length, diameter, crown-to-implant ratio, and types of prostheses were investigated. Statistical data were analyzed using SPSS Win.Ver 14.0 software with the χ² test. The survival rate of the 4.1-mm-diameter implants was 100% and 91.2% for the 5.0-mm-diameter implants. The survival rates of the implants of differing diameters were found to be statistically different (P = 0.005). The survival rates of both the 5.0-mm and 7.0-mm-length implants were 100%. The survival rate of the 9.0-mm-length implants was 97.9% and for the 12.0-mm-length implants was 95.1%. There was no statistical difference in survival rates for the differing lengths of implants. Of the 103 prostheses that were splinted, the survival rate was 98.0%. The survival rate of splinted prostheses was higher than that of the nonsplinted prostheses but was found to be not statistically different. There were no failed cases when the crown-to-implant ratio was <1.0. When the crown-to-implant ratio was between 1.0 and 1.4, the failure rate of the implants was 6.7%. No failure was recorded with the ratio range of 1.5 to 2.0. Relative to the crown-to-implant ratio of 1.0, the failure rates were statistically different (P = 0.048). The cumulative survival rate of the porous-surfaced implants placed in the edentulous posterior mandibles was 97.5%. Short porous-surfaced implants showed satisfactory results after a maximum of 9 years of functioning in the edentulous posterior mandibles.
NASA Astrophysics Data System (ADS)
Bui-Thanh, T.; Girolami, M.
2014-11-01
We consider the Riemann manifold Hamiltonian Monte Carlo (RMHMC) method for solving statistical inverse problems governed by partial differential equations (PDEs). The Bayesian framework is employed to cast the inverse problem into the task of statistical inference whose solution is the posterior distribution in infinite dimensional parameter space conditional upon observation data and Gaussian prior measure. We discretize both the likelihood and the prior using the H1-conforming finite element method together with a matrix transfer technique. The power of the RMHMC method is that it exploits the geometric structure induced by the PDE constraints of the underlying inverse problem. Consequently, each RMHMC posterior sample is almost uncorrelated/independent from the others providing statistically efficient Markov chain simulation. However this statistical efficiency comes at a computational cost. This motivates us to consider computationally more efficient strategies for RMHMC. At the heart of our construction is the fact that for Gaussian error structures the Fisher information matrix coincides with the Gauss-Newton Hessian. We exploit this fact in considering a computationally simplified RMHMC method combining state-of-the-art adjoint techniques and the superiority of the RMHMC method. Specifically, we first form the Gauss-Newton Hessian at the maximum a posteriori point and then use it as a fixed constant metric tensor throughout RMHMC simulation. This eliminates the need for the computationally costly differential geometric Christoffel symbols, which in turn greatly reduces computational effort at a corresponding loss of sampling efficiency. We further reduce the cost of forming the Fisher information matrix by using a low rank approximation via a randomized singular value decomposition technique. This is efficient since a small number of Hessian-vector products are required. The Hessian-vector product in turn requires only two extra PDE solves using the adjoint technique. Various numerical results up to 1025 parameters are presented to demonstrate the ability of the RMHMC method in exploring the geometric structure of the problem to propose (almost) uncorrelated/independent samples that are far away from each other, and yet the acceptance rate is almost unity. The results also suggest that for the PDE models considered the proposed fixed metric RMHMC can attain almost as high a quality performance as the original RMHMC, i.e. generating (almost) uncorrelated/independent samples, while being two orders of magnitude less computationally expensive.
Jei, J Brintha; Mohan, Jayashree
2014-03-01
The periodontal health of abutment teeth and the durability of fixed partial denture depends on the marginal adaptation of the prosthesis. Any discrepancy in the marginal area leads to dissolution of luting agent and plaque accumulation. This study was done with the aim of evaluating the accuracy of marginal fit of four unit crown and bridge made up of Ni-Cr and Cr-Co alloys under induction and centrifugal casting. They were compared to cast fixed partial denture (FPD) and soldered FPD. For the purpose of this study a metal model was fabricated. A total of 40 samples (4-unit crown and bridge) were prepared in which 20 Cr-Co samples and 20 Ni-Cr samples were fabricated. Within these 20 samples of each group 10 samples were prepared by induction casting technique and other 10 samples with centrifugal casting technique. The cast FPD samples obtained were seated on the model and the samples were then measured with travelling microscope having precision of 0.001 cm. Sectioning of samples was done between the two pontics and measurements were made, then the soldering was made with torch soldering unit. The marginal discrepancy of soldered samples was measured and all findings were statistically analysed. The results revealed minimal marginal discrepancy with Cr-Co samples when compared to Ni-Cr samples done under induction casting technique. When compared to cast FPD samples, the soldered group showed reduced marginal discrepancy.
Repair of the posterior root of the medial meniscus.
Jones, Christopher; Reddy, Sudheer; Ma, C Benjamin
2010-01-01
Tears of the posterior root of the medial meniscus are becoming increasingly recognized. Early identification and treatment of these tears help halt the progression of cartilage degeneration and osteoarthritis of the knee. Repair of these tears is essential for recreating the hoop stress of the medial meniscus. In this note, we describe a successful arthroscopic technique to repair this lesion. A posteromedial portal is established by which two 2-0 PDS sutures are placed through the meniscus root and pulled down through a trans-tibial tunnel and fixed using an EndoButton distally along the anterolateral cortex of the tibia. This has been performed successfully in five patients with no complications.
Bacchi, Ataís; Consani, Rafael L X; Mesquita, Marcelo F; dos Santos, Mateus B F
2013-09-01
The purpose of this study was to evaluate the influence of superstructure material and vertical misfits on the stresses created in an implant-supported partial prosthesis. A three-dimensional (3-D) finite element model was prepared based on common clinical data. The posterior part of a severely resorbed jaw with two osseointegrated implants at the second premolar and second molar regions was modeled using specific modeling software (SolidWorks 2010). Finite element models were created by importing the solid model into mechanical simulation software (ANSYS Workbench 11). The models were divided into groups according to the prosthesis framework material (type IV gold alloy, silver-palladium alloy, commercially pure titanium, cobalt-chromium alloy, or zirconia) and vertical misfit level (10 µm, 50 µm, and 100 µm) created at one implant-prosthesis interface. The gap of the vertical misfit was set to be closed and the stress values were measured in the framework, porcelain veneer, retention screw, and bone tissue. Stiffer materials led to higher stress concentration in the framework and increased stress values in the retention screw, while in the same circumstances, the porcelain veneer showed lower stress values, and there was no significant difference in stress in the peri-implant bone tissue. A considerable increase in stress concentration was observed in all the structures evaluated within the misfit amplification. The framework material influenced the stress concentration in the prosthetic structures and retention screw, but not that in bone tissue. All the structures were significantly influenced by the increase in the misfit levels.
Bilateral posterior crystalline lens dislocations in an otherwise healthy child.
AlShehri, Omar A; Almarzouki, Hashem; Alharbi, Badr A; Alqahtani, Mohammed; Allam, Khaled
2017-01-01
Introduction: Ectopia lentis is defined as a crystalline lens displacement, either partially or completely, due to zonular abnormalities. It can be a result of trauma, hereditary ocular disease, or part of systemic diseases, like Marfan syndrome and homocystinuria. Case description: We report a case of a medically free 16-year-old girl, who was referred to our hospital complaining of poor vision and a squint in both eyes since childhood. Her history included a traffic accident when she was one-year-old. She was previously diagnosed with alternating esotropia, which was treated with glasses, alternating patching, and bilateral Botox injections. On examination, she had a visual acuity of 6/7.5 with correction in the right eye and 6/6 with correction in the left eye. She had an esotropia of 60 prism diopters, which was partially corrected to 40 prism diopters for near and distance vision. Fundus examination showed myopic changes in each eye and dislocated lenses in the posterior pole at 6 o'clock. Our case was stable, so we used conservative management with contact lenses. Conclusion: Bilateral posterior lens dislocation is very rare. A proper examination is important and early diagnosis can prevent serious complications, such as retinal detachment or pupillary block glaucoma.
Effect of posterior cruciate ligament rupture on the radial displacement of lateral meniscus.
Lei, Pengfei; Sun, Rongxin; Hu, Yihe; Li, Kanghua; Liao, Zhan
2015-06-01
The relationship between lateral meniscus tear and posterior cruciate ligament injury is not well understood. The present study aims to investigate and assess the effect of posterior cruciate ligament rupture on lateral meniscus radial displacement at different flexion angles under static loading conditions. Twelve fresh human cadaveric knee specimens were divided into four groups such as posterior cruciate ligament intact, anterolateral band rupture, posteromedial band rupture and posterior cruciate ligament complete rupture groups, according to the purpose and order of testing. Radial displacement of lateral meniscus was measured under different loads (200-1000N) at 0°, 30°, 60°, and 90° of knee flexion. Compared with posterior cruciate ligament intact group, the displacement values of lateral meniscus in anterolateral band rupture group increased at 0° flexion with 600N, 800N, and 1000N and at 30°, 60° and 90° flexion under all loading conditions. Posteromedial band rupture group exhibited higher displacement at 0° flexion under all loading conditions, at 30° and 60° flexion with 600, 800N and 1000N, and at 90° flexion with 400N, 600N, 800N, and 1000N than the posterior cruciate ligament intact group. The posterior cruciate ligament complete rupture group had a higher displacement value of lateral medial meniscus at 0°, 30°, 60° and 90° flexion under all loading conditions, as compared to the posterior cruciate ligament intact group. The study concludes that partial and complete rupture of the posterior cruciate ligament can trigger the increase of radial displacement on lateral meniscus. Copyright © 2015 Elsevier Ltd. All rights reserved.
Akar, Serpil; Gokyigit, Birsen; Sayin, Nihat; Demirok, Ahmet; Yilmaz, Omer Faruk
2013-01-01
To evaluate the results of Faden operations on the medial rectus (MR) muscles with or without recession for the treatment of partially accommodative esotropia associated with a high accommodative convergence to accommodation (AC : A) ratio and to determine whether there was a decrease in the effects of posterior fixation over time. In this retrospective study, 108 of 473 patients who underwent surgery for partially accommodative esotropia with a high AC : A ratio received Faden operations on both MR muscles, and 365 received symmetric MR muscle recessions combined with a Faden operation. For the Faden operation, a satisfactory outcome of 76.9% at 1 month postoperation, decreased to 71.3% by the final follow-up visit (mean 4.8 years). A moderate positive correlation was observed between the increase in the postoperative near deviation and postoperative time. For the Faden operations combined with MR recession, a satisfactory outcome of 78.9% at 1 month post-operation, decreased to 78.4% by the final follow-up visit. A Faden operation of the MR muscles with or without recession is an effective surgical option for treating partially accommodative esotropia associated with a high AC : A ratio. For Faden operations of the MR muscles without recession, the effects of the posterior fixation decline over time.
Cho, Jin-Ho; Song, Jae-Gwang
2014-06-01
To identify the structural integrity of the healing site after arthroscopic repair of a posterior root tear of the medial meniscus by second-look arthroscopy and to determine the clinical relevance of the findings. From January 2005 to December 2010, 20 consecutive patients underwent arthroscopic modified pull-out suture repair for a posterior root tear of the medial meniscus. Thirteen patients were available for second-look arthroscopic evaluation. The healing status of the medial meniscus was classified as complete healing, lax healing, scar tissue healing, and failed healing. We evaluated the correlation between the clinical symptoms and second-look arthroscopic findings. Clinical evaluation was based on the Lysholm knee scores and Hospital for Special Surgery (HSS) scores. There were 4 cases of complete healing, 4 lax healing, 4 scar tissue healing, and 1 failed healing. The healing status of the repaired meniscus appeared to be related to the clinical symptoms. Patients who achieved complete tissue healing had no complaint. The healing status exhibited no relationship with age, mechanical axis, degree of subluxation, and symptom duration. The mean Lysholm score improved from 34.7 preoperatively to 75.6 at follow-up and the mean HSS score also significantly increased from 33.5 to 82.2. We achieved 4 complete and 8 partial healing (lax or scar) of the medial meniscus in this retrospective case series of posterior horn meniscus root repairs performed by 1 surgeon. Further research is needed to clarify why all patients showed clinical improvement despite findings of partial healing on second-look arthroscopy.
Bayesian randomized clinical trials: From fixed to adaptive design.
Yin, Guosheng; Lam, Chi Kin; Shi, Haolun
2017-08-01
Randomized controlled studies are the gold standard for phase III clinical trials. Using α-spending functions to control the overall type I error rate, group sequential methods are well established and have been dominating phase III studies. Bayesian randomized design, on the other hand, can be viewed as a complement instead of competitive approach to the frequentist methods. For the fixed Bayesian design, the hypothesis testing can be cast in the posterior probability or Bayes factor framework, which has a direct link to the frequentist type I error rate. Bayesian group sequential design relies upon Bayesian decision-theoretic approaches based on backward induction, which is often computationally intensive. Compared with the frequentist approaches, Bayesian methods have several advantages. The posterior predictive probability serves as a useful and convenient tool for trial monitoring, and can be updated at any time as the data accrue during the trial. The Bayesian decision-theoretic framework possesses a direct link to the decision making in the practical setting, and can be modeled more realistically to reflect the actual cost-benefit analysis during the drug development process. Other merits include the possibility of hierarchical modeling and the use of informative priors, which would lead to a more comprehensive utilization of information from both historical and longitudinal data. From fixed to adaptive design, we focus on Bayesian randomized controlled clinical trials and make extensive comparisons with frequentist counterparts through numerical studies. Copyright © 2017 Elsevier Inc. All rights reserved.
[Case of occlusal reconstruction for severe attrition].
Ueda, Takayuki
2006-01-01
A 57-year-old female complained of aesthetic disturbance, dysmasesis and phonation disorder by attrition. She had severe attrition of almost teeth. To avoid metal color exposure and attrition of opposing teeth, hybrid ceramics were used for veneered crowns and fixed partial denture. Since the prosthetic treatment, the patient wears a night guard to prevent attrition of her teeth and prosthesis. There has been no specific trouble during the 4-year follow-up. It is considered that using hybrid ceramics for veneering crowns and fixed partial denture and night guard help to prevent the attrition of opposing teeth and abrasion of prosthesis.
Partial supraspinatus tears are associated with tendon lengthening.
Farshad-Amacker, Nadja A; Buck, Florian M; Farshad, Mazda; Pfirrmann, Christian W A; Gerber, Christian
2015-02-01
Tendon tear may result in muscular retraction with the loss of contractile amplitude and strength of the rotator cuff muscles. Currently, neither a validated method of measuring supraspinatus tendon length nor normal values are known. It was therefore the purpose of this study to measure the normal length of the supraspinatus tendon and to determine whether partial tears are associated with changes in tendon length. MR examinations of 49 asymptomatic volunteers and 37 patients with arthroscopically proven, isolated partial tears of the supraspinatus tendon were compared. The ratio of the extramuscular tendon length to the distance between the footprint and the glenoid surface was calculated (TL/FG ratio). Tendon length measurements were taken by two independent readers at the bursal and articular surfaces at the anterior, the central and the posterior parts of the tendon. TL/FG ratios at the bursal surface of tendons with partial tears were significantly higher than those in the control group [anterior: 0.78 ± 0.20 vs. 0.66 ± 0.15 (p < 0.05); central: 0.61 ± 0.13 vs. 0.52 ± 0.10 (p < 0.05); posterior: 0.57 ± 0.15 vs. 0.52 ± 0.10 (p < 0.05)]. At the articular surface, differences were significant only anteriorly [0.60 ± 0.13, vs. 0.54 ± 0.10 (p < 0.05)]. A cut-off TL/FG ratio of 0.63 for measurements at the bursal surface in the center of the tendon achieved a sensitivity of 46 % and a specificity of 92 % for the identification of partial cuff tearing. A reproducible method for measurement of extramuscular supraspinatus tendon length is described. Partial tearing of the supraspinatus tendon is associated with significant tendon lengthening, suggesting failure in continuity, and this is most reliably measured on the bursal surface. III.
48 CFR 49.208 - Equitable adjustment after partial termination.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Equitable adjustment after partial termination. 49.208 Section 49.208 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT TERMINATION OF CONTRACTS Additional Principles for Fixed-Price Contracts...
EAO consensus conference: economic evaluation of implant-supported prostheses.
Beikler, Thomas; Flemmig, Thomas F
2015-09-01
There are various alternatives for the management of oral conditions that may lead to or already have lead to partial or full edentulism. Economic evaluations measure the efficiency of alternative healthcare interventions and provide useful information for decision-making and the allocation of scarce resources. The current English literature dealing with "cost-effectiveness" of dental implant therapy versus different alternative treatment modalities, that is, complete and fixed partial dentures, root canal, and periodontal treatment, has been included in this narrative review. Due to the high heterogeneity within the literature, a meta-analysis could not be conducted. The available evidence from economic evaluations indicated that for the treatment of central incisors with irreversible pulpitis and coronal lesions, root canal treatments were most cost-effective initial treatment options. When initial root canal treatments failed, orthograde retreatments were most cost-effective. When root canal retreatments failed, extractions and replacement with single implant-supported crowns were more cost-effective compared to fixed or removable partial dentures. In the treatment of periodontitis in molars with Class I furcation invasion, non-surgical periodontal therapy was more effective and costed less than implant-supported single crowns. For the replacement of single missing teeth, two evaluations indicated that implant-supported single crowns provided better outcomes in terms of greater quality-adjusted tooth years or survival rates at lower costs compared to fixed partial prostheses. Another economic evaluation found that implant-supported crowns costed more, but provided greater survival rates compared to fixed partial dentures. For the restoration of edentulous mandibles, two evaluations indicated that overdentures retained by two or four implants improved oral health-related quality of life outcomes, but costed more than complete dentures. To better assess the efficiency of implant-supported prostheses in various clinical conditions, more economic evaluations are needed that follow well-established methodologies in health economics. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Styranivska, Oksana; Kliuchkovska, Nataliia; Mykyyevych, Nataliya
2017-01-01
To analyze the stress-strain states of bone and abutment teeth during the use of different prosthetic designs of fixed partial dentures with the use of relevant mathematical modeling principles. The use of Comsol Multiphysics 3.5 (Comsol AB, Sweden) software during the mathematical modeling of stress-strain states provided numerical data for analytical interpretation in three different clinical scenarios with fixed dentures and different abutment teeth and demountable prosthetic denture with the saddle-shaped intermediate part. Microsoft Excel Software (Microsoft Office 2017) helped to evaluate absolute mistakes of stress and strain parameters of each abutment tooth during three modeled scenarios and normal condition and to summarize data into the forms of tables. In comparison with the fixed prosthetic denture supported by the canine, first premolar, and third molar, stresses at the same abutment teeth with the use of demountable denture with the saddle-shaped intermediate part decreased: at the mesial abutment tooth by 2.8 times, at distal crown by 6.1 times, and at the intermediate part by 11.1 times, respectively, the deformation level decreased by 3.1, 1.9, and 1.4 times at each area. The methods of mathematical modeling proved that complications during the use of fixed partial dentures based on the overload effect of the abutment teeth and caused by the deformation process inside the intermediate section of prosthetic construction.
ERIC Educational Resources Information Center
Cai, Li
2013-01-01
Lord and Wingersky's (1984) recursive algorithm for creating summed score based likelihoods and posteriors has a proven track record in unidimensional item response theory (IRT) applications. Extending the recursive algorithm to handle multidimensionality is relatively simple, especially with fixed quadrature because the recursions can be defined…
Development of uncertainty-based work injury model using Bayesian structural equation modelling.
Chatterjee, Snehamoy
2014-01-01
This paper proposed a Bayesian method-based structural equation model (SEM) of miners' work injury for an underground coal mine in India. The environmental and behavioural variables for work injury were identified and causal relationships were developed. For Bayesian modelling, prior distributions of SEM parameters are necessary to develop the model. In this paper, two approaches were adopted to obtain prior distribution for factor loading parameters and structural parameters of SEM. In the first approach, the prior distributions were considered as a fixed distribution function with specific parameter values, whereas, in the second approach, prior distributions of the parameters were generated from experts' opinions. The posterior distributions of these parameters were obtained by applying Bayesian rule. The Markov Chain Monte Carlo sampling in the form Gibbs sampling was applied for sampling from the posterior distribution. The results revealed that all coefficients of structural and measurement model parameters are statistically significant in experts' opinion-based priors, whereas, two coefficients are not statistically significant when fixed prior-based distributions are applied. The error statistics reveals that Bayesian structural model provides reasonably good fit of work injury with high coefficient of determination (0.91) and less mean squared error as compared to traditional SEM.
Arikupurathu, Oommen Mathew; Johnston, Linda; MacInnes, Alasdair; Nicol, Graeme; Nassif, Manhal
2018-06-20
The NexGen legacy posterior stabilized (LPS) prosthesis was introduced in 1997 after many design changes to its predecessor, the Insall-Burstein II prosthesis. However, there have been no reported long-term studies on the performance of this implant. Prospectively, collected data from a local database comprising primary total knee replacements (TKRs) with LPS between 1997 and 2002 was analyzed. All implants were fixed with cement. Patients were followed up at 1, 3, 5, 7, and 10 years, with patient satisfaction, range of movement, and Knee Society score (KSS) assessed. A total of 621 primary TKRs were analyzed with an average follow-up of 11.25 years (9.15-14.55). The mean age was 69.53 years. The mean KSS was 88.97 and mean flexion increased from 88.3 to 103.5 degrees at 10 years. Kaplan-Meier's analysis revealed a survivorship of 96.5% with revision for any reason as the end point and 98.9% if aseptic loosening was the reason for revision at 14 years. This study revealed excellent mid- to long-term results with the NexGen LPS prosthesis. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Posterior consistency in conditional distribution estimation
Pati, Debdeep; Dunson, David B.; Tokdar, Surya T.
2014-01-01
A wide variety of priors have been proposed for nonparametric Bayesian estimation of conditional distributions, and there is a clear need for theorems providing conditions on the prior for large support, as well as posterior consistency. Estimation of an uncountable collection of conditional distributions across different regions of the predictor space is a challenging problem, which differs in some important ways from density and mean regression estimation problems. Defining various topologies on the space of conditional distributions, we provide sufficient conditions for posterior consistency focusing on a broad class of priors formulated as predictor-dependent mixtures of Gaussian kernels. This theory is illustrated by showing that the conditions are satisfied for a class of generalized stick-breaking process mixtures in which the stick-breaking lengths are monotone, differentiable functions of a continuous stochastic process. We also provide a set of sufficient conditions for the case where stick-breaking lengths are predictor independent, such as those arising from a fixed Dirichlet process prior. PMID:25067858
Kumagai, Koshi; Kjellin, Ann; Tsai, Jon A; Thorell, Anders; Granqvist, Staffan; Lundell, Lars; Håkanson, Bengt
2014-01-01
The optimal anti-reflux procedure after Heller cardiomyotomy for oesophageal achalasia remains unclear. The most commonly used procedure is the anterior partial fundoplication according to Dor, although during recent years the posterior counterpart (Toupet) has become popular. Patients with newly diagnosed achalasia and referred for cardiomyotomy were randomised to receive either an anterior or partial posterior fundoplication following a classical cardiomyotomy. The effect of surgery was assessed during the first postoperative year by Eckardt scores, EORTC QLQ-OES18 scores and HRQL questionnaires. Timed barium oesophagogram (TBO) and ambulatory 24-h pH monitoring were performed to determine oesophageal emptying and the degree of reflux control, respectively. Forty-two patients were randomised into Dor (n = 20) and Toupet (n = 22) groups. Eckardt scores improved dramatically with both procedures, but the EORTC QLQ-OES18 (functional scales) scores revealed significantly better relative improvements in the Toupet group compared to the Dor repair (P = 0.044). Corresponding advantages in favour of Toupet were observed postoperatively in the percentage of oesophageal emptying at TBO (P = 0.011 in height and P = 0.018 in area), an effect not observed in the Dor group. There were no other significant differences recorded between the study groups concerning HRQL evaluations and objective assessment of gastro-oesophageal acid reflux. A partial posterior fundoplication after cardiomyotomy seems to achieve more improvement in oesophageal emptying and EORTC QLQ-OES18 functional scale scores than the anterior fundoplication. Otherwise no differences between the two anti-reflux repairs were noted. ClinicalTrials.gov Identifier: NCT01933373. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Management of benign dynamic "A-shape" tracheal stenosis: a retrospective study of 60 patients.
Plojoux, Jérôme; Laroumagne, Sophie; Vandemoortele, Thomas; Astoul, Philippe J; Thomas, Pascal A; Dutau, Hervé
2015-02-01
Benign tracheal stenosis complicates tracheal intubation or tracheostomy in 0.6% to 65% of cases. Surgical resection is the standard treatment. Endoscopic management is used for inoperable patients with 17% to 69% success. Dynamic "A-shape" tracheal stenosis (DATS) results in a dynamic stenosis with anterior fracture of tracheal cartilage and frequently associated posterior malacia. We report the results of our multidisciplinary management. Sixty patients with DATS were included. Management decision was made during initial bronchoscopy. When suitable, patients were referred to thoracic surgery for tracheal resection. Posterior localized tracheomalacia was treated with laser photocoagulation of the posterior tracheal wall. Tracheal stents were placed if the stenosis persisted after laser treatment. The choice of stent (straight silicone, hour-glass shaped silicone, T-tube, or fully-covered self-expandable metallic stent) was based on operator's judgment. After 12 to 18 months, stents were removed. If the stenosis persisted after stent removal, surgery was reconsidered. If surgery was not possible, a stent was replaced. In case of satisfactory result, a stent was replaced only after recurrence. Stable patients after treatment were considered as success, requirement of long-term tracheostomy or T tube as failure, and long-term stent as partial success. All patients developed DATS after tracheostomy. Thirty-three patients had posterior tracheomalacia. In 13 patients, mild stenosis required only endoscopic surveillance. Two patients were referred to thoracic surgery for tracheal resection surgery. Endoscopic management was the initial therapy in 45 patients (75%) and was considered successful in 23 patients (51%), partially successful in 10 (22%), and failed in 12 (27%). Five patients with successful outcomes required only laser therapy. Overall 70 stents were placed in 35 patients, with a migration rate of 31%. The DATS management was successful in 63%. Stent migration was frequent. Posterior tracheomalacia was successfully treated in selected cases, avoiding stent placement. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Kinsel, Richard P; Lin, Dongming
2009-06-01
Porcelain fracture associated with an implant-supported, metal ceramic crown or fixed partial denture occurs at a higher rate than in tooth-supported restorations, according to the literature. Implant-specific and patient-specific causes of ceramic failure have not been fully evaluated. The purpose of this retrospective study was to evaluate the potential statistical predictors for porcelain fracture of implant-supported, metal ceramic restorations. Over a 6-month period, a consecutive series of patients having previously received implant-supported, metal ceramic fixed restorations were examined during periodic recall appointments. The number of supporting implants, number of dental units, type of restoration, date of prosthesis insertion, location in the dental arch, opposing dentition, type of occlusion, presence of parafunctional habits, use of an occlusal protective device, presence or absence of ceramic fractures, gender, and age were recorded for each patient. The generalized estimating equation (GEE) approach was used for the intrasubject correlated measurements analysis of categorical outcomes (presence or absence of ceramic fractures) to determine which patient- and implant-specific factors would predict porcelain fracture (alpha=.05). Data were collected from 152 patients representing 998 dental units (390 single crowns and 94 fixed partial dentures) supported by 729 implants. Porcelain fractures of 94 dental units occurred in 35 patients. The fractures were significantly (P<.05) associated with opposing implant-supported metal ceramic restorations, bruxism, and not wearing a protective occlusal device. Metal ceramic prostheses (single crown or fixed partial dentures) had approximately 7 times higher odds of porcelain fracture (odds ratio (OR)=7.06; 95% confidence interval (CI): 2.57 to 19.37) and 13 times greater odds of a fracture requiring either repair or replacement (OR=13.95; 95% CI: 2.25 to 86.41) when in occlusion with another implant-supported restoration, as compared to opposing a natural tooth. In addition, patients exhibiting bruxism or not wearing an occlusal device had approximately 7 times higher odds (OR=7.23; 95% CI: 3.86 to 13.54), and 2 times higher odds (OR=1.92; 95% CI: 1.01 to 3.67) of porcelain fracture when compared to patients without bruxism and patients not wearing an occlusal device. Implant-supported metal ceramic single crowns and fixed partial dentures were found to have a significantly higher risk of porcelain fracture in patients with bruxism habits, when a protective occlusal device was not used, and when the restoration opposed another implant-supported metal ceramic restoration.
Piedra, Mark P; Hunt, Matthew A; Nemecek, Andrew N
2009-10-01
Early fixation of type II odontoid fractures has been shown to provide high rates of long-term stabilization and osteosynthesis. In this report, the authors present the case of a patient with a locked type II odontoid fracture treated by anterior screw fixation facilitated by closed transoral and posterior cervical manual reduction. While transoral intraoperative reduction of a partially displaced odontoid fracture has previously been described, the authors present the first case utilizing this technique in the treatment of a completely dislocated type II odontoid fracture.
Leland, J Martin
2016-10-01
With knee arthroscopy being the most common orthopaedic procedure performed in the United States, it is crucial to be able to access the entire knee without iatrogenic injury. Frequently orthopaedic surgeons encounter tight medial compartments, creating difficulty in accessing the posterior horn of the medial meniscus without damaging the articular cartilage. Partial release of the medial collateral ligament during knee arthroscopy protects chondrocytes. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
[Prelabour uterine torsion complicated by partial abruption and fetal death].
Agar, N; Canis, M; Accoceberry, M; Bourdel, N; Lafaye, A-L; Gallot, D
2014-06-01
Uterine torsion is a rare obstetrical complication whose diagnosis remains challenging. We report a case of 180 degrees dextrogyre torsion at 36(+5) weeks of gestation complicated by partial abruption and in utero fetal death. Emergency cesarean section was performed through an unintentional posterior hysterotomy. Literature reports a few similar cases. Vertical hysterotomy should be advised in this context avoiding incision on lateral sides associated with increased risk of vascular or ureteral injury. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Reidenbach, M M
1995-01-01
The posterior cricothyroid ligament and its topographic relation to the inferior laryngeal nerve were studied in 54 human adult male and female larynges. Fourteen specimens were impregnated with curable polymers and cut into 600-800 microns sections along different planes. Forty formalin-fixed hemi-larynges were dissected and various measurements were made. The posterior cricothyroid ligament provides a dorsal strengthening for the joint capsule of the cricothyroid joint. Its fibers spread in a fan-like manner from a small area of origin at the cricoid cartilage to a more extended area of attachment at the inferior thyroid cornu. The ligament consists of one (7.5%) to four (12.5%), in most cases of three (45.0%) or two (35.0%), individual parts oriented from mediocranial to latero-caudal. The inferior laryngeal nerve courses immediately dorsal to the ligament. In 60% it is covered by fibers of the posterior cricoarytenoid muscle, in the remaining 40% it is not. In this latter topographic situation there is almost no soft tissue interposed between the nerve and the hypopharynx. Therefore, the nerve may be exposed to pressure forces exerted from dorsally. It may be pushed against the unyielding posterior cricothyroid ligament and suffer functional or structural impairment. Probably, this mechanism may explain some of the laryngeal nerve lesions described in the literature after insertion of gastric tubes.
Donor cornea preparation in partial big bubble deep anterior lamellar keratoplasty.
Lim, Li; Lim, Samuel Wen Yan
2014-01-01
The purpose of this paper is to describe a technique of donor cornea preparation to ensure good graft-host apposition in incomplete big bubble deep anterior lamellar keratoplasty. Following a partial-thickness trephination, manual dissection and excision of corneal stroma was performed. Anwar's big-bubble technique involving a deep stromal air injection was then initiated. However, the big bubble could not extend to the trephination edge and the peripheral residual corneal stroma could not be removed. Donor cornea preparation involving trimming of the posterior lip of the corneal button was then performed and good graft-host apposition was obtained without graft over-ride. We performed peripheral donor cornea trimming prior to allograft placement in order to ensure good graft-host apposition. Postoperatively, best-corrected visual acuity in both eyes was 6/7.5. Donor cornea preparation involving trimming of the posterior lip of the corneal button is a useful technique in instances where the big bubble does not extend to the trephination edge and ensures good graft-host apposition.
Beitzel, Knut; Obopilwe, Elifho; Apostolakos, John; Cote, Mark P; Russell, Ryan P; Charette, Ryan; Singh, Hardeep; Arciero, Robert A; Imhoff, Andreas B; Mazzocca, Augustus D
2014-09-01
Many reconstructions of acromioclavicular (AC) joint dislocations have focused on the coracoclavicular (CC) ligaments and neglected the functional contribution of the AC ligaments and the deltotrapezial fascia. To compare the modifications of previously published methods for direct AC reconstruction in addition to a CC reconstruction. The hypothesis was that there would be significant differences within the variations of surgical reconstructions. Controlled laboratory study. A total of 24 cadaveric shoulders were tested with a servohydraulic testing system. Two digitizing cameras evaluated the 3-dimensional movement. All reconstructions were based on a CC reconstruction using 2 clavicle tunnels and a tendon graft. The following techniques were used to reconstruct the AC ligaments: a graft was shuttled underneath the AC joint back from anterior and again sutured to the acromial side of the joint (group 1), a graft was fixed intramedullary in the acromion and distal clavicle (group 2), a graft was passed over the acromion and into an acromial tunnel (group 3), and a FiberTape was fixed in a cruciate configuration (group 4). Anterior, posterior, and superior translation, as well as anterior and posterior rotation, were tested. Group 1 showed significantly less posterior translation compared with the 3 other groups (P < .05) but did not show significant differences compared with the native joint. Groups 3 and 4 demonstrated significantly more posterior translation than the native joint. Group 1 showed significantly less anterior translation compared with groups 2 and 3. Group 3 demonstrated significantly more anterior translation than the native joint. Group 1 demonstrated significantly less superior translation compared with the other groups and with the native joint. The AC joint of group 1 was pulled apart less compared with all other reconstructions. Only group 1 reproduced the native joint for the anterior rotation at the posterior marker. Group 4 showed significantly increased distances for all 3 measure points when the clavicle was rotated posteriorly. Reconstruction of the AC ligament by direct wrapping and suturing of the remaining graft around the AC joint (group 1) was the most stable method and was the only one to show anterior rotation comparable with the native joint. In contrast, the transacromial technique (group 3) showed the most translation and rotation. An anatomic repair should address both the CC ligaments and the AC ligaments to control the optimal physiologic function (translation and rotation). © 2014 The Author(s).
NASA Astrophysics Data System (ADS)
Zeyl, Timothy; Yin, Erwei; Keightley, Michelle; Chau, Tom
2016-04-01
Objective. Error-related potentials (ErrPs) have the potential to guide classifier adaptation in BCI spellers, for addressing non-stationary performance as well as for online optimization of system parameters, by providing imperfect or partial labels. However, the usefulness of ErrP-based labels for BCI adaptation has not been established in comparison to other partially supervised methods. Our objective is to make this comparison by retraining a two-step P300 speller on a subset of confident online trials using naïve labels taken from speller output, where confidence is determined either by (i) ErrP scores, (ii) posterior target scores derived from the P300 potential, or (iii) a hybrid of these scores. We further wish to evaluate the ability of partially supervised adaptation and retraining methods to adjust to a new stimulus-onset asynchrony (SOA), a necessary step towards online SOA optimization. Approach. Eleven consenting able-bodied adults attended three online spelling sessions on separate days with feedback in which SOAs were set at 160 ms (sessions 1 and 2) and 80 ms (session 3). A post hoc offline analysis and a simulated online analysis were performed on sessions two and three to compare multiple adaptation methods. Area under the curve (AUC) and symbols spelled per minute (SPM) were the primary outcome measures. Main results. Retraining using supervised labels confirmed improvements of 0.9 percentage points (session 2, p < 0.01) and 1.9 percentage points (session 3, p < 0.05) in AUC using same-day training data over using data from a previous day, which supports classifier adaptation in general. Significance. Using posterior target score alone as a confidence measure resulted in the highest SPM of the partially supervised methods, indicating that ErrPs are not necessary to boost the performance of partially supervised adaptive classification. Partial supervision significantly improved SPM at a novel SOA, showing promise for eventual online SOA optimization.
Emami, Elham; St-Georges, Annie; de Grandmont, Pierre
2012-01-01
In this case report, we describe the successful long-term treatment of a patient with dental agenesis. The initial treatment plan included an orthodontic phase to provide adequate space for replacing missing lateral incisors with implants. However, because of some complications encountered after 2 years of orthodontic treatment, a revised treatment plan was considered to achieve functional and esthetic goals. The patient was completely satisfied 5 years after being treated with two 2-unit cantilevered resin-bonded fixed partial dentures supported by the cuspids. This conservative treatment plan was cost-effective without having any significant biological cost.
Morphometric Study of the Anterior Thalamoperforating Arteries
Kim, Sung-Ho; Yeo, Dong-Kyu; Shim, Jae-Joon; Yoon, Seok-Mann; Chang, Jae-Chil
2015-01-01
Objective To evaluate the morphometry of the anterior thalamoperforating arteries (ATPA). Methods A microanatomical study was performed in 79 specimens from 42 formalin-fixed adult cadaver brains. The origins of the ATPAs were divided into anterior, middle, and posterior segments according to the crowding pattern. The morphometry of the ATPAs, including the premammillary artery (PMA), were examined under a surgical microscope. Results The anterior and middle segments of the ATPAs arose at mean intervals of 1.75±1.62 mm and 5.86±2.05 mm from the internal carotid artery (ICA), and the interval between these segments was a mean of 3.17±1.64 mm. The posterior segment arose at a mean interval of 2.43±1.46 mm from the posterior cerebral artery (PCA), and the interval between the middle and posterior segments was a mean of 3.45±1.39 mm. The mean numbers of perforators were 2.66±1.19, 3.03±1.84, and 1.67±0.98 in the anterior, middle, and posterior segments, respectively. The PMA originated from the middle segment in 66% of cases. A perforator-free zone was located >2 mm from the ICA in 30.4% and >2 mm from the PCA in 67.1% of cases. Conclusion Most perforators arose from the anterior and middle segments, within the anterior two-thirds of the posterior communicating artery (PCoA). The safest perforator-free zone was located closest to the PCA. These anatomical findings may be helpful to verify safety when treating lesions around the PCoA and in the interpeduncular fossa. PMID:26113962
DOE Office of Scientific and Technical Information (OSTI.GOV)
La Russa, D
Purpose: The purpose of this project is to develop a robust method of parameter estimation for a Poisson-based TCP model using Bayesian inference. Methods: Bayesian inference was performed using the PyMC3 probabilistic programming framework written in Python. A Poisson-based TCP regression model that accounts for clonogen proliferation was fit to observed rates of local relapse as a function of equivalent dose in 2 Gy fractions for a population of 623 stage-I non-small-cell lung cancer patients. The Slice Markov Chain Monte Carlo sampling algorithm was used to sample the posterior distributions, and was initiated using the maximum of the posterior distributionsmore » found by optimization. The calculation of TCP with each sample step required integration over the free parameter α, which was performed using an adaptive 24-point Gauss-Legendre quadrature. Convergence was verified via inspection of the trace plot and posterior distribution for each of the fit parameters, as well as with comparisons of the most probable parameter values with their respective maximum likelihood estimates. Results: Posterior distributions for α, the standard deviation of α (σ), the average tumour cell-doubling time (Td), and the repopulation delay time (Tk), were generated assuming α/β = 10 Gy, and a fixed clonogen density of 10{sup 7} cm−{sup 3}. Posterior predictive plots generated from samples from these posterior distributions are in excellent agreement with the observed rates of local relapse used in the Bayesian inference. The most probable values of the model parameters also agree well with maximum likelihood estimates. Conclusion: A robust method of performing Bayesian inference of TCP data using a complex TCP model has been established.« less
Park, Jung-Hyun; Kim, Minkyu; Kim, Sang Yoon; Jung, Hwi-Dong; Jung, Young-Soo
2016-04-01
To evaluate three-dimensional change in maxillary position using biodegradable plates. A total of 53 patients who underwent orthognathic surgery using biodegradable plates were analyzed retrospectively. The position of maxilla was measured three-dimensionally using cone beam computed tomography data at preoperative (T0), 1-month postoperative (T1), and 1-year postoperative (T2) time points. Changes in the maxilla 1 year after the operation (T2-T1) were analyzed to demonstrate postoperative stability. The correlation between postoperative relapse (T2-T1) and surgical movement (T1-T0) of the maxilla was investigated. At 1-year postoperatively, no significant changes in maxillary position were noted in the antero-posterior and transverse dimensions. The anterior maxillary position in the vertical dimension also showed no significant changes, but the posterior maxillary position (posterior nasal spine, greater palatine foramen) showed a 0- to 2.98-mm relapse at 1-year postoperatively. The posterior maxilla tended to relapse inferiorly when the amount of surgical upward movement was greater than 3-3.5 mm and to relapse superiorly when the amount of surgical upward movement was less than 3-3.5 mm. For all patients, no postoperative complications in the osteofixated maxilla were observed during the follow-up period. Maxilla fixed with biodegradable plates was stable in the antero-posterior and transverse and the vertical (anterior maxilla) dimensions. Posterior maxillary vertical relapse was clinically acceptable, but relapse patterns that relate to the amount of surgical upward movement should be considered for surgical treatment planning. Copyright © 2016. Published by Elsevier Ltd.
Holtman, J R
1988-07-01
Retrograde tracing with a fluorescent dye (Fast Blue) combined with immunohistochemistry was used to determine if the putative neurotransmitters, serotonin and substance P, are present around posterior cricoarytenoid muscle motoneurons. Fast Blue was injected into the posterior cricoarytenoid muscle of the larynx. Following a 14-21 day survival time to allow for transport of the dye, the animals were perfusion fixed and the brainstem was removed for analysis under the fluorescence microscope. Retrogradely labeled cell bodies containing Fast Blue were found within the nucleus ambiguus from 0.5 to 3.0 mm rostral to obex. These motoneurons ranged in size from 23 to 38 micron. The same tissue sections containing labeled posterior cricoarytenoid muscle motoneurons were then used to determine the distribution of serotonin and substance P around these motoneurons using the indirect immunofluorescence technique. A dense network of serotonin-containing immunoreactive fibers was found around posterior cricoarytenoid muscle motoneurons. The fibers contained varicosities which were in close proximity, actually appearing to surround these motoneurons. Substance P immunoreactive fibers and varicosities were also found around posterior cricoarytenoid muscle motoneurons. The density and pattern of distribution of the substance P immunoreactivity was similar to that of the serotonin immunoreactivity. These results suggest that these putative neurotransmitters may be involved in influencing the activity of posterior cricoarytenoid muscle motoneurons. Serotonin and substance P are also present around other respiratory motoneurons such as phrenic motoneurons. Therefore, these two neurotransmitters may have a more general role in influencing respiratory motor outflow.
Scuderi, Giles R; Hedden, David R; Maltry, John A; Traina, Steven M; Sheinkop, Mitchell B; Hartzband, Mark A
2012-03-01
Between May 2001 and June 2004, 388 total knee arthroplasty cases were enrolled in a prospective, randomized, multicenter investigational device exemption trial. Patients received either the investigational high-flexion mobile-bearing knee or a fixed-bearing control. At 2 to 4 years of follow-up, results in 293 patients with degenerative joint disease were compared using Knee Society Assessment and Function scores, radiographic results, complications analysis, and survival estimates. The mobile-bearing and fixed-bearing groups demonstrated similar, significant improvement over preoperative assessments in Knee Scores, maximum flexion, and range of motion. One mobile-bearing arthroplasty required revision. Radiographic results were unremarkable, and implant-related complications were rare in both groups. At this early follow-up, the investigational high-flexion mobile-bearing knee and its fixed-bearing counterpart demonstrated comparable, effective performance. Copyright © 2012 Elsevier Inc. All rights reserved.
Song, Jae-Gwang
2014-01-01
Purpose To identify the structural integrity of the healing site after arthroscopic repair of a posterior root tear of the medial meniscus by second-look arthroscopy and to determine the clinical relevance of the findings. Materials and Methods From January 2005 to December 2010, 20 consecutive patients underwent arthroscopic modified pull-out suture repair for a posterior root tear of the medial meniscus. Thirteen patients were available for second-look arthroscopic evaluation. The healing status of the medial meniscus was classified as complete healing, lax healing, scar tissue healing, and failed healing. We evaluated the correlation between the clinical symptoms and second-look arthroscopic findings. Clinical evaluation was based on the Lysholm knee scores and Hospital for Special Surgery (HSS) scores. Results There were 4 cases of complete healing, 4 lax healing, 4 scar tissue healing, and 1 failed healing. The healing status of the repaired meniscus appeared to be related to the clinical symptoms. Patients who achieved complete tissue healing had no complaint. The healing status exhibited no relationship with age, mechanical axis, degree of subluxation, and symptom duration. The mean Lysholm score improved from 34.7 preoperatively to 75.6 at follow-up and the mean HSS score also significantly increased from 33.5 to 82.2. Conclusions We achieved 4 complete and 8 partial healing (lax or scar) of the medial meniscus in this retrospective case series of posterior horn meniscus root repairs performed by 1 surgeon. Further research is needed to clarify why all patients showed clinical improvement despite findings of partial healing on second-look arthroscopy. PMID:24944976
Ohira, Suguru; Doi, Kiyoshi; Yaku, Hitoshi
2016-04-05
We describe a simple method to fix the great saphenous vein graft (SVG) to the right coronary artery along the atrioventricular groove using fibrin glue in off-pump coronary artery bypass grafting (OPCAB). After completion of the proximal anastomosis, the SVG was placed along the atrioventricular groove to the acute margin. Fibrin glue was sprayed using pressurized carbon dioxide gas. A distal anastomosis was subsequently performed after rotating the heart to expose the posterior descending artery. It is a straightforward and reproducible technique to determine the optimal length of the SVG and prevent kinking or stretching of the graft, especially in OPCAB.
Laparoscopic Sacral Colpopexy: The "6-Points" Technique.
Schaub, Marie; Lecointre, Lise; Faller, Emilie; Boisramé, Thomas; Baldauf, Jean-Jacques; Wattiez, Arnaud; Akladios, Cherif Youssef
To illustrate laparoscopic sacral colpopexy for pelvic organ prolapse, a new method using a simplified mesh fixation technique, with only 6 fixing points. Step-by-step explanation of the surgery using video (educative video). The video was approved by the local institutional review board. University Hospital of Strasbourg, France (Canadian Task Force Classification III). Women with multicompartment prolapse. We first dissected the promontorium and vertically incise the posterior parietal peritoneum on the right pelvic sidewall up the pouch of Douglas. We then dissect the rectovaginal septum up to the anal cap, laterally exposing the puborectalis muscle on each side. Middle rectal vessels can be coagulated and cut without increasing the risk of digestive disorders (especially constipation), but it is preferable to conserve them if the space is sufficient for suture. Then, we dissect the vesicovaginal space and realized the subtotal hysterectomy. Finally, we realized the fastening of the anterior and posterior meshes. The particularity is that we performed only 6 points for fixing the meshes: 1 on the puborectalis muscle on each side without tension (to reduce the risk of mesh contracture, dyspareunia, and chronic pelvic pain), 1 for the fixing of the anterior mesh on the anterior vaginal wall at the level of the bladder neck, and 1 on each side of the cervix for the reconstitution of the pericervical ring gathering together the anterior mesh, the pubocervical fascia, and the insertion of the uterosacral ligament at the level of the cervix and the posterior mesh. The sixth stitch fastened 1 of 2 meshes to the anterior paravertebral ligament at the level of the sacral promontory. We finished with the peritonization. The duration of surgery lasts approximately 120 minutes in well-experienced hands. Based on our experience the 6-point technique was relatively simple (few laparoscopic stiches) with few operative difficulties and was also associated with a low rate of reintervention. Surgical management of middle compartment prolapse could be performed quickly and efficiently under laparoscopy with the "6-points" technique. Copyright © 2017 AAGL. Published by Elsevier Inc. All rights reserved.
Leonard, Charles E; Tallhamer, Michael; Johnson, Tim; Hunter, Kari; Howell, Kathryn; Kercher, Jane; Widener, Jodi; Kaske, Terese; Paul, Devchand; Sedlacek, Scot; Carter, Dennis L
2010-02-01
To explore the feasibility of fiducial markers for the use of image-guided radiotherapy (IGRT) in an accelerated partial breast intensity modulated radiotherapy protocol. Nineteen patients consented to an institutional review board approved protocol of accelerated partial breast intensity-modulated radiotherapy with fiducial marker placement and treatment with IGRT. Patients (1 patient with bilateral breast cancer; 20 total breasts) underwent ultrasound guided implantation of three 1.2- x 3-mm gold markers placed around the surgical cavity. For each patient, table shifts (inferior/superior, right/left lateral, and anterior/posterior) and minimum, maximum, mean error with standard deviation were recorded for each of the 10 BID treatments. The dose contribution of daily orthogonal films was also examined. All IGRT patients underwent successful marker placement. In all, 200 IGRT treatment sessions were performed. The average vector displacement was 4 mm (range, 2-7 mm). The average superior/inferior shift was 2 mm (range, 0-5 mm), the average lateral shift was 2 mm (range, 1-4 mm), and the average anterior/posterior shift was 3 mm (range, 1 5 mm). This study shows that the use of IGRT can be successfully used in an accelerated partial breast intensity-modulated radiotherapy protocol. The authors believe that this technique has increased daily treatment accuracy and permitted reduction in the margin added to the clinical target volume to form the planning target volume. Copyright 2010 Elsevier Inc. All rights reserved.
Cordaro, Luca; Ercoli, Carlo; Rossini, Carlo; Torsello, Ferruccio; Feng, Changyong
2005-10-01
The clinical outcome of complete-arch fixed prostheses supported by implants and natural tooth abutments in patients with normal or reduced periodontal support has been reported by few studies, with controversial results. The purpose of this study was to report on the implant success rate, prosthetic complications, and the occurrence of tooth intrusion, when complete-arch fixed prostheses, supported by a combination of implants and teeth, were fabricated for patients with normal and reduced periodontal support. Nineteen patients with residual teeth that served as abutments were consecutively treated with combined tooth- and implant-supported complete-arch fixed prostheses and were retrospectively evaluated after a period varying from 24 to 94 months. Nine patients showed reduced periodontal support as a result of periodontal disease and treatment (RPS group), and 10 patients had normal periodontal support of the abutment teeth (more than 2/3 of periodontal support [NPS group]). Ninety implants and 72 tooth abutments were used to support 19 fixed partial dentures. Screw- and cement-retained metal-ceramic and metal-resin prostheses were fabricated with rigid and nonrigid connectors. Implant survival and success rates, occurrence of caries and tooth intrusion, and prosthetic complications were recorded. The number of teeth, implants, prosthetic units, fixed partial dentures, and nonrigid connectors were compared with a t test to assess differences between the 2 groups, while data for the occurrence of intrusions and prosthetic complications were compared with the Fisher exact test (alpha=.05). One of the 90 implants was lost (99% survival rate) over 24 to 94 months, while 3 implants showed more than 2 mm of crestal bone loss (96% success rate) over the same period. No caries were detected, but 5.6% (4/72) of the abutment teeth exhibited intrusion. Intrusion of abutment teeth was noted in 3 patients who had normal periodontal support (13% of teeth in NPS group) of the abutment teeth and was associated with nonrigid connectors. No intrusion of teeth was noted in the patients exhibiting reduced periodontal support regardless of the type of connector or when a rigid connector was used for either group. The number of intruded teeth was significantly greater in patients with intact periodontal support (P=.03). Complete-arch fixed prosthesis supported by implant and tooth abutments may be associated with intrusion of teeth with intact periodontal support when nonrigid connectors are used to join the implant- and tooth-supported sections of the prostheses. However, fixed partial dentures supported by implants and teeth with reduced periodontal support were not associated with tooth intrusion, regardless of the type of connectors used.
NASA Astrophysics Data System (ADS)
Sheikhnejad, Yahya; Hosseini, Reza; Saffar Avval, Majid
2017-02-01
In this study, steady state laminar ferroconvection through circular horizontal tube partially filled with porous media under constant heat flux is experimentally investigated. Transverse magnetic fields were applied on ferrofluid flow by two fixed parallel magnet bar positioned on a certain distance from beginning of the test section. The results show promising notable enhancement in heat transfer as a consequence of partially filled porous media and magnetic field, up to 2.2 and 1.4 fold enhancement were observed in heat transfer coefficient respectively. It was found that presence of both porous media and magnetic field simultaneously can highly improve heat transfer up to 2.4 fold. Porous media of course plays a major role in this configuration. Virtually, application of Magnetic field and porous media also insert higher pressure loss along the pipe which again porous media contribution is higher that magnetic field.
De Boever, J A
1990-05-01
Placing restorations in patients who have a limited number of teeth and reduced periodontal support is no longer controversial, given careful selection of patients, preprosthetic periodontal treatment, and a thorough maintenance program. In this paper, attention is drawn to general prosthetic planning, including the use of long-span bridges. Because of increased tooth mobility, cross-arch stabilization of the bridges with interlocks or with postsolder connections is advocated. The framework should be rigid enough to avoid deflection of the bridges. Preparation of the vital and nonvital abutment teeth needs much attention. To avoid using a removable prosthesis, a cantilever bridge can be used, but it makes the construction more prone to fracture. A number of periodontal-prosthetic patients demonstrate a "posterior collapsed bite." Rehabilitation requires the restoration at a "new" vertical dimension of occlusion. This can be done, without functional hazards, in a one-step clinical procedure. A long functional adaptation period is unnecessary. The treatment outcome of furcations is not always predictable. Therefore, hemisection or amputation are often the treatments of choice. On these hemisected roots, bridges can be made and successfully maintained. Finally, it should be stressed that not all teeth have to be replaced: a premolar, shortened-arch occlusion is often sufficient for adequate function.
Petri, Maximilian; Greenspoon, Joshua A.; Bhatia, Sanjeev; Millett, Peter J.
2015-01-01
Latissimus dorsi transfer is a reasonable treatment option for massive posterosuperior rotator cuff tears that can substantially improve chronically painful and dysfunctional shoulders. This report and accompanying video describe the treatment of an active 43-year-old man with severe pain and weakness in the right shoulder after 3 failed rotator cuff repairs. Preoperative imaging showed a massive posterosuperior rotator cuff tear retracted to the glenoid as well as a hypermobile os acromiale likely causing dynamic impingement and recurrent rotator cuff tears. After diagnostic arthroscopy, the latissimus tendon is harvested and augmented with a 3-mm human acellular dermal patch (ArthroFlex; Arthrex, Naples, FL). The native rotator cuff tissue is repaired as much as possible, and the latissimus tendon is passed underneath the deltoid and posterior to the teres minor. The patch-augmented tendon is then integrated into a double-row SpeedBridge repair of eight 4.75-mm BioComposite SwiveLock anchors (Arthrex). The bony surface of the os acromiale is prepared and then fixed to the acromion with 2 cannulated partially threaded screws and additional tension-band wiring. Postoperative rehabilitation initially focuses on early passive range of motion, followed by active and active-assisted motion and a biofeedback program starting at 6 weeks postoperatively. PMID:26697309
Glenohumeral internal rotation deficit in throwing athletes: current perspectives
Rose, Michael B; Noonan, Thomas
2018-01-01
Glenohumeral internal rotation deficit (GIRD) is an adaptive process in which the throwing shoulder experiences a loss of internal rotation (IR). GIRD has most commonly been defined by a loss of >20° of IR compared to the contralateral shoulder. Total rotational motion of the shoulder is the sum of internal and external rotation and may be more important than the absolute value of IR loss. Pathologic GIRD has been defined as a loss of IR combined with a loss of total rotational motion. The leading pathologic process in GIRD is posterior capsular and rotator-cuff tightness, due to the repetitive cocking that occurs with the overhead throwing motion. GIRD has been associated with numerous pathologic conditions, including posterior superior labral tears, partial articular-sided rotator-cuff tears, and superior labral anterior-to-posterior tears. The mainstay of treatment for patients with GIRD is posterior capsular stretching and strengthening to improve scapular mechanics. In patients who fail nonoperative therapy, shoulder arthroscopy can be performed. Arthroscopic surgery in the high-level throwing athlete should be to restore them to their functional baseline with the minimum amount of intervention possible. PMID:29593438
[Chronic pain and syringomyelic slit of the posterior horns of the spinal cord].
Rémillard, G M; Robitaille, Y; Bertrand, G
1985-01-01
Two male patients 46 and 44 y.o. respectively, were admitted for a syndrome of chronic pain characterized by: sudden onset, spontaneous or following spasmodic coughing, of an anterior hemithoracic pain slowly progressing to involve several unilateral cervicothoracic dermatomes, a continuous burning sensation made worse by light touch, limb movements and cold water, and partially relieved by warm water or deep palpation. On examination, patient 1 revealed no sensorimotor deficit after repeated observations during 8 years. At autopsy, a syrinx localized at the cord segments corresponding to the symptoms was found without documentation of specific causal factors. It involved the posterior horn of the cord selectively. In patient 2, pain was associated with slight hypesthesia to pinprick and heat from C2 to T5 on the left without motor deficit since 18 months. A high resolution C.A.T. scan showed an intramedullary cavity 0.3 cm from the midline in the projection of the posterior horn without anomalies at the cervicomedullary junction. These observations link chronic pain syndromes with predominantly posterior horn lesions, which so far have failed to respond to conventional therapeutic measures.
Brownstein, D G; Barthold, S W
1982-02-01
Mouse hepatitis viral antigens were demonstrated by immunofluorescence in formalin- and Bouin's-fixed tissues processed routinely for histopathology followed by partial digestion with trypsin. Staining was superior in tissues fixed in formalin and was not diminished in tissue sections from paraffin blocks stored at room temperature as long as 2 years. The relative ease of this procedure and the commercial availability of reagents makes this a useful technique for the definitive diagnosis of mouse hepatitis virus infection.
Harsha, Madhavareddy Sri; Praffulla, Mynampati; Babu, Mandava Ramesh; Leneena, Gudugunta; Krishna, Tejavath Sai; Divya, G
2017-05-01
Cavity preparations of posterior teeth have been frequently associated with decreased fracture strength of the teeth. Choosing the correct indirect restoration and the cavity design when restoring the posterior teeth i.e., premolars was difficult as it involves aesthetic, biomechanical and anatomical considerations. To evaluate the fracture resistance and failure pattern of three different cavity designs restored with monolithic zirconia. Human maxillary premolars atraumatically extracted for orthodontic reasons were chosen. A total of 40 teeth were selected and divided into four groups (n=10). Group I-Sound teeth (control with no preparation). Group II-MOD Inlay, Group III-Partial Onlay, Group IV-Complete Onlay. Restorations were fabricated with monolithic partially sintered zirconia CAD (SAGEMAX- NexxZr). All the 30 samples were cemented using Multilink Automix (Ivoclar) and subjected to fracture resistance testing using Universal Testing Machine (UTM) (Instron) with a steel ball of 3.5 mm diameter at crosshead speed of 0.5 mm/minute. Stereomicroscope was used to evaluate the modes of failure of the fractured specimen. Fracture resistance was tested using parametric one way ANOVA test, unpaired t-test and Tukey test. Fracture patterns were assessed using non-parametric Chi-square test. Group IV (Complete Onlay) presented highest fracture resistance and showed statistical significant difference. Group II (MOD Inlay) and Group III (Partial Onlay) showed significantly lower values than the Group I (Sound teeth). However, Groups I, II and III presented no significant difference from each other. Coming to the modes of failure, Group II (MOD Inlay) and Group III (Partial Onlay) presented mixed type of failures; Group IV (Complete Onlay) demonstrated 70% Type I failures. Of the three cavity designs evaluated, Complete Onlay had shown a significant increase in the fracture resistance than the Sound teeth.
Roks, D J; Koetje, J H; Oor, J E; Broeders, J A; Nieuwenhuijs, V B; Hazebroek, E J
2017-06-01
Partial fundoplications provide similar reflux control with fewer post-fundoplication symptoms compared with Nissen fundoplication for gastro-oesophageal reflux disease (GORD). The best choice of procedure for partial fundoplication remains unclear. The aim of this study was to compare the outcome of two different types of partial fundoplication for GORD. A double-blind RCT was conducted between 2012 and 2015 in two hospitals specializing in antireflux surgery. Patients were randomized to undergo either a laparoscopic 270° posterior fundoplication (Toupet) or a laparoscopic 180° anterior fundoplication. The primary outcome was postoperative dysphagia at 12 months, measured by the Dakkak score. Subjective outcome was analysed at 1, 3, 6 and 12 months after surgery. Objective reflux control was assessed before and 6 months after surgery. Ninety-four patients were randomized to laparoscopic Toupet or laparoscopic 180° anterior fundoplication (47 in each group). At 12 months, 85 patients (90 per cent) were available for follow-up. Objective scores were available for 76 (81 per cent). Postoperative Dakkak dysphagia score at 12 months was similar in the two groups (mean 5·9 for Toupet versus 6·4 for anterior fundoplication; P = 0·773). Subjective outcome at 12 months demonstrated no significant differences in control of reflux or post-fundoplication symptoms. Overall satisfaction and willingness to undergo surgery did not differ between the groups. Postoperative endoscopy and 24-h pH monitoring showed no significant differences in mean oesophageal acid exposure time or recurrent pathological oesophageal acid exposure. Both types of partial fundoplication provided similar control of GORD at 12 months, with no difference in post-fundoplication symptoms. Registration number: NTR5702 (www.trialregister.nl). © 2017 BJS Society Ltd Published by John Wiley & Sons Ltd.
Distally based posterior interosseous flap: primary role in soft-tissue reconstruction of the hand.
Agir, Hakan; Sen, Cenk; Alagöz, Sahin; Onyedi, Murat; Isil, Eda
2007-09-01
A series of 15 consecutive patients with various hand defects requiring flap coverage was reviewed in this study. The defects were all covered with the distally based posterior interosseous flap. Its main indications were in complex hand trauma, severe burn injury, or skin cancer ablation, either acute or postprimary. In 12 of the patients, flaps survived completely. In 3 patients, there was partial necrosis of the distal part of the flap, which did not require additional surgical procedure. Radial nerve palsy was noted in one of the cases, with a complete recovery after 3 months. Donor site was closed directly in up to 4-cm-wide flaps, while larger flaps required skin grafting. No major anatomic variation was observed. Distally based posterior interosseous flap is a reliable choice for various types and areas of hand defects, with very low donor-site morbidity, and should be more commonly considered in clinical practice.
Reestablishment of occlusion through overlay removable partial dentures: a case report.
Bataglion, César; Hotta, Takami Hirono; Matsumoto, Wilson; Ruellas, Carlos Ventura de Oliveira
2012-01-01
Loss of posterior teeth may cause an imbalance in the stomatognathic system. Overlay removable partial dentures (ORPD) are a reversible and relatively inexpensive treatment for patients with severely worn teeth. This paper presents a treatment with ORPD in a 55-year-old male patient who had severe attrition in the maxillary and mandibular teeth, temporomandibular joint pain and reduced vertical dimension of occlusion (VDO). The treatment consisted in the reestablishment of the VDO using Lucia's jig, fabricating removable partial denture with reconstruction of the worn teeth without preparation. This therapy can be used as an alternative treatment to provide esthetic, function and stable occlusion in patients with severely worn teeth.
Pang, Xiaoyang; Wu, Ping; Shen, Xiongjie; Li, Dongzhe; Luo, Chenke; Wang, Xiyang
2013-08-01
Retrospective analysis of the clinical study efficacy and feasibility of one-stage posterior transforaminal lumbar debridement, 360° interbody fusion, and posterior instrumentation in treating lumbosacral spinal tuberculosis. A total of 21 patients with lumbosacral tuberculosis (TB) collected from January 2004 to January 2010, underwent one-stage posterior transforaminal lumbar debridement, 360° interbody fusion, and posterior instrumentation. In addition, the clinical efficacy was evaluated based on the data on the lumbo-sacral angle, neuro-logical status that was recorded by American Spinal Injury Association (ASIA) Impairment Scale, erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP), which were collected at specific time points. All cases were followed up for 16-36 months (average 24.9 ± 6.44 months). 18 patients suffered from evident neurological deficits preoperatively, of which 16 patients returned to normal at the final follow-up. Two patients with neurological dysfunction aggravated postoperative, experienced significant partial neurological recovery. With an effective and standard anti-TB chemotherapy treated, the values of ESR and CRP returned to normal levels 3-month later postoperative and maintained till the final follow-up. Preoperative lumbosacral angle was 20.89 ± 2.32° and returned 29.62 ± 1.41° postoperative. During long-term follow-up, there was only 1-3° lumbosacral angle loss. There was a significant difference between preoperative and postoperative lumbosacral angles. With effective and standard anti-TB chemotherapy, one-stage posterior transforaminal lumbar debridement, 360° interbody fusion, and posterior instrumentation for lumbosacral tuberculosis can effectively relieve pain symptoms, improve neurological function, and reconstruct the spinal stability.
Gelman, Joel; Wisenbaugh, Eric S.
2015-01-01
Pelvic fracture urethral injuries are typically partial and more often complete disruptions of the most proximal bulbar and distal membranous urethra. Emergency management includes suprapubic tube placement. Subsequent primary realignment to place a urethral catheter remains a controversial topic, but what is not controversial is that when there is the development of a stricture (which is usually obliterative with a distraction defect) after suprapubic tube placement or urethral catheter removal, the standard of care is delayed urethral reconstruction with excision and primary anastomosis. This paper reviews the management of patients who suffer pelvic fracture urethral injuries and the techniques of preoperative urethral imaging and subsequent posterior urethroplasty. PMID:26691883
NASA Technical Reports Server (NTRS)
Maklad, Adel; Fritzsch, Bernd
2002-01-01
The developmental segregation of gravistatic input mediated by saccular fibers and of angular acceleration input mediated by posterior crista (PC) fibers was analyzed for the first time in a developing mammal using carbocyanine dye tracing in fixed tissue. The data reveal a more extensive projection of either endorgan in 7-day-old mice (P7) than has previously been reported in adult mammals. While we confirm and extend many previous findings, we also describe a novel segregation of saccular and posterior crista fibers in the anterior half of the medial vestibular nucleus (Mv) not reported before. Our developmental analysis shows a progressive segregation of posterior crista and saccular fibers to their respective discrete projection areas between embryonic day 15 (E15) and birth (P0). Retention of overlap in young adult animals appears to reflect the early embryonic overlap found in most areas. The vestibular projection does not show a topological projection as has been described in many other sensory systems. We propose that the unique projection features of the vestibular endorgans may relate to the transformation of vestibular signals into a motor output in the three neuron reflex arc of the VOR, of which the primary vestibular projection constitutes the first leg.
Miyazaki, Masashi; Kanezaki, Shozo; Notani, Naoki; Ishihara, Toshinobu; Tsumura, Hiroshi
2017-12-01
Fixed thoracolumbar kyphosis with spinal stenosis in adult patients with achondroplasia presents a challenging issue. We describe the first case in which spondylectomy and minimally invasive lateral access interbody arthrodesis were used for the treatment of fixed severe thoracolumbar kyphosis and lumbar spinal canal stenosis in an adult with achondroplasia. A 61-year-old man with a history of achondroplastic dwarfism presented with low back pain and radiculopathy and neurogenic claudication. Plain radiographs revealed a high-grade thoracolumbar kyphotic deformity with diffuse degenerative changes in the lumbar spine. The apex was located at L2, the local kyphotic angle from L1 to L3 was 105°, and the anterior area was fused from the L1 to L3 vertebrae. MRI revealed significant canal and lateral recess stenosis secondary to facet hypertrophy. We planned a front-back correction of the anterior and posterior spinal elements. We first performed anterior release at the fused part from L1 to L3 and XLIF at L3/4 and L4/5. Next, the patient was placed in the prone position. Spondylectomy at the L2 vertebra and posterior fusion from T10 to L5 were performed. Postoperative radiographs revealed L1 to L3 kyphosis of 32°. No complications occurred during or after surgery. Postoperatively, the patient's low back pain and neurological claudication were resolved. No worsening of kyphosis was observed 24 months postoperatively. Circumferential decompression of the spinal cord at the apical vertebral level and decompression of lumbar canal stenosis were necessary. Front-back correction of the anterior and posterior spinal elements via spondylectomy and lateral lumbar interbody fusion is a reasonable surgical option for thoracolumbar kyphosis and developmental canal stenosis in patients with achondroplasia.
Ardestani, Marzieh M; Moazen, Mehran; Maniei, Ehsan; Jin, Zhongmin
2015-04-01
Commercially available fixed bearing knee prostheses are mainly divided into two groups: posterior stabilized (PS) versus cruciate retaining (CR). Despite the widespread comparative studies, the debate continues regarding the superiority of one type over the other. This study used a combined finite element (FE) simulation and principal component analysis (PCA) to evaluate "reliability" and "sensitivity" of two PS designs versus two CR designs over a patient population. Four fixed bearing implants were chosen: PFC (DePuy), PFC Sigma (DePuy), NexGen (Zimmer) and Genesis II (Smith & Nephew). Using PCA, a large probabilistic knee joint motion and loading database was generated based on the available experimental data from literature. The probabilistic knee joint data were applied to each implant in a FE simulation to calculate the potential envelopes of kinematics (i.e. anterior-posterior [AP] displacement and internal-external [IE] rotation) and contact mechanics. The performance envelopes were considered as an indicator of performance reliability. For each implant, PCA was used to highlight how much the implant performance was influenced by changes in each input parameter (sensitivity). Results showed that (1) conformity directly affected the reliability of the knee implant over a patient population such that lesser conformity designs (PS or CR), had higher kinematic variability and were more influenced by AP force and IE torque, (2) contact reliability did not differ noticeably among different designs and (3) CR or PS designs affected the relative rank of critical factors that influenced the reliability of each design. Such investigations enlighten the underlying biomechanics of various implant designs and can be utilized to estimate the potential performance of an implant design over a patient population. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Sihota, Ramanjit; Goyal, Amita; Kaur, Jasbir; Gupta, Viney; Nag, Tapas C
2012-01-01
To study ultrastructural changes of the trabecular meshwork in acute and chronic primary angle closure glaucoma (PACG) and primary open angle glaucoma (POAG) eyes by scanning electron microscopy. Twenty-one trabecular meshwork surgical specimens from consecutive glaucomatous eyes after a trabeculectomy and five postmortem corneoscleral specimens were fixed immediately in Karnovsky solution. The tissues were washed in 0.1 M phosphate buffer saline, post-fixed in 1% osmium tetraoxide, dehydrated in acetone series (30-100%), dried and mounted. Normal trabecular tissue showed well-defined, thin, cylindrical uveal trabecular beams with many large spaces, overlying flatter corneoscleral beams and numerous smaller spaces. In acute PACG eyes, the trabecular meshwork showed grossly swollen, irregular trabecular endothelial cells with intercellular and occasional basal separation with few spaces. Numerous activated macrophages, leucocytes and amorphous debris were present. Chronic PACG eyes had a few, thickened posterior uveal trabecular beams visible. A homogenous deposit covered the anterior uveal trabeculae and spaces. Converging, fan-shaped trabecular beam configuration corresponded to gonioscopic areas of peripheral anterior synechiae. In POAG eyes, anterior uveal trabecular beams were thin and strap-like, while those posteriorly were wide, with a homogenous deposit covering and bridging intertrabecular spaces, especially posteriorly. Underlying corneoscleral trabecular layers and spaces were visualized in some areas. In acute PACG a marked edema of the endothelium probably contributes for the acute and marked intraocular pressure (IOP) elevation. Chronically raised IOP in chronic PACG and POAG probably results, at least in part, from decreased aqueous outflow secondary to widening and fusion of adjacent trabecular beams, together with the homogenous deposit enmeshing trabecular beams and spaces.
Grohmann, Philipp; Bindl, Andreas; Hämmerle, Christoph; Mehl, Albert; Sailer, Irena
2015-01-01
The aim of this multicenter randomized controlled clinical trial was to test posterior zirconia-ceramic fixed dental prostheses (FDPs) veneered with a computer-aided design/computer- assisted manufacture (CAD/CAM) lithium disilicate veneering ceramic (CAD-on) and manually layered zirconia veneering ceramic with respect to survival of the FDPs, and technical and biologic outcomes. Sixty patients in need of one posterior three-unit FDP were included. The zirconia frameworks were produced with a CAD/CAM system (Cerec inLab 3D/Cerec inEOS inLab). Thirty FDPs were veneered with a CAD/CAM lithium disilicate veneering ceramic (Cad-on) (test) and 30 were veneered with a layered zirconia veneering ceramic (control). For the clinical evaluation at baseline, 6, and 12 months, the United States Public Health Service (USPHS) criteria were used. The biologic outcome was judged by comparing the plaque control record (PCR), bleeding on probing (BOP), and probing pocket depth (PPD). Data were statistically analyzed. Fifty-six patients were examined at a mean follow-up of 13.9 months. At the 1-year follow-up the survival rate was 100% in the test and in the control group. No significant differences of the technical outcomes occurred. Major chipping occurred in the control group (n = 3) and predominantly minor chipping in the test group (minor n = 2, major n = 1). No biologic problems or differences were found. Both types of zirconia-ceramic FDPs exhibited very good clinical outcomes without differences between groups. Chipping occurred in both types of FDPs at small amounts, yet the extension of the chippings differed. The test FDPs predominantly exhibited minor chipping, the control FDPs major chipping.
Al-Habib, Amro F; Al-Rabie, Abdulkarim; Aleissa, Sami; Albakr, Abdulrahman; Abobotain, Abdulaziz
2017-01-01
This was an interventional human cadaver study and radiological study. Atlas instrumentation is frequently involved in fusion procedures involving the craniocervical junction area. Identification of the entry point at the center of atlas lateral mass (ALM) is challenging because of its rounded posterior surface and the surrounding venous plexus. This report examines using the medial edge of atlas posterior arch (MEC1) as a fixed and reliable anatomic reference to guide the entry point of ALM screws. Fifty, normal, cervical spine computed tomography studies were reviewed. ALM screw trajectories were planned at one point along MEC1 and another point 2 mm lateral to MEC1. Free-hand ALM instrumentation was performed in ten fresh human cadavers using the 2 mm entry point, with a sagittal trajectory parallel to atlas inferior arch (IAC1); three-dimensional imaging was then performed to confirm instrumentation accuracy. The average ALM diameter was 12.35 mm. Inserting a screw using the entry point 2 mm lateral to MEC1 was closer to ALM midpoint than using the entry point along MEC1 ( P < 0.0001). Twenty ALM screws were successfully inserted in the ten cadavers. No encroachments into the spinal canal or foramen transversarium occurred. However, two screws were superiorly directed and violated the occipitocervical joint; they were not parallel to IAC1. MEC1 provides a fixed and reliable landmark for ALM instrumentation. An entry point 2 mm point lateral to MEC1 is close to ALM midpoint. IAC1 also provides a guide for the sagittal trajectory. Attention to anatomic landmarks may help reduce complications associated with atlas instrumentation but should be verified in future clinical studies.
Schultheis, Stefan; Strub, Joerg R; Gerds, Thomas A; Guess, Petra C
2013-06-01
The authors analyzed the effect of fatigue on the survival rate and fracture load of monolithic and bi-layer CAD/CAM lithium-disilicate posterior three-unit fixed dental prostheses (FDPs) in comparison to the metal-ceramic gold standard. The authors divided 96 human premolars and molars into three equal groups. Lithium-disilicate ceramic (IPS-e.max-CAD) was milled with the CEREC-3-system in full-anatomic FDP dimensions (monolithic: M-LiCAD) or as framework (Bi-layer: BL-LiCAD) with subsequent hand-layer veneering. Metal-ceramic FDPs (MC) served as control. Single-load-to-failure tests were performed before and after mouth-motion fatigue. No fracture failures occurred during fatigue. Median fracture loads in [N], before and after fatigue were, respectively, as follows: M-LiCAD, 1,298/1,900; BL-LiCAD, 817/699; MC, 1,966/1,818. M-LiCAD and MC FPDs revealed comparable fracture loads and were both significantly higher than BL-LiCAD. M-LiCAD and BL-LiCAD both failed from core/veneer bulk fracture within the connector area. MC failures were limited to ceramic veneer fractures exposing the metal core. Fatigue had no significant effect on any group. Posterior monolithic CAD/CAM fabricated lithium-disilicate FPDs were shown to be fracture resistant with failure load results comparable to the metal-ceramic gold standard. Clinical investigations are needed to confirm these promising laboratory results. Monolithic CAD/CAM fabricated lithium-disilicate FDPs appeared to be a reliable treatment alternative for the posterior load-bearing area, whereas FDPs in bi-layer configuration were susceptible to low load fracture failure.
Nicolaisen, Maj H; Bahrami, Golnosh; Schropp, Lars; Isidor, Flemming
2016-01-01
The aim of this study was to assess functional and esthetic satisfaction plus evaluate changes in oral health-related quality of life (OHRQoL) using the Oral Health Impact Profile (OHIP-14) after insertion of a metal-ceramic (MC-FDP) or a veneered zirconia all-ceramic (AC-FDP) posterior three-unit fixed dental prosthesis (FDP). Additionally, patients' and professionals' esthetic evaluations were compared. A convenience sample of 34 patients was randomized to receive a MC-FDP (n = 17) or an AC-FDP (n = 17). Patients were assessed using the OHIP-14 and also answered a questionnaire regarding satisfaction with function and esthetics using visual analog scales (VAS) before treatment and after 2 weeks, after 3 months, and after 1, 2, and 3 years. A fully dentate control group (n = 20) was also assessed using the OHIP-14. The operator and another observer evaluated the esthetics of the FDPs using VAS. The patients assessed the two FDP types similarly for all parameters. In contrast, there was a statistically significant difference in OHIP-14 results between the treated patients and the control group before treatment. After treatment, a statistically significant improvement in OHIP-14 was observed at all examinations. Patients were highly satisfied with the function and esthetics of the FDPs. The overall satisfaction with esthetics was statistically significantly higher among the patients than among the professionals at three out of five examinations. The patients experienced improved OHRQoL and increased satisfaction with function and esthetics after receiving a posterior three-unit FDP. No important differences were observed between the two types of FDPs when evaluated by the patient or the professionals.
Nelson, Joshua D; McIff, Terence E; Moodie, Patrick G; Iverson, Jamey L; Horton, Greg A
2010-03-01
Internal fixation of the os calcis is often complicated by prolonged soft tissue management and posterior facet disruption. An ideal calcaneal construct would include minimal hardware prominence, sturdy posterior facet fixation and nominal soft tissue disruption. The purpose of this study was to develop such a construct and provide a biomechanical analysis comparing our technique to a standard internal fixation technique. Twenty fresh-frozen cadaver calcanei were used to create a reproducible Sanders type-IIB calcaneal fracture pattern. One calcaneus of each pair was randomly selected to be fixed using our compressive headless screw technique. The contralateral matched calcaneus was fixed with a nonlocking calcaneal plate in a traditional fashion. Each calcaneus was cyclically loaded at a frequency of 1 Hz for 4000 cycles using an increasing force from 250 N to 1000 N. An Optotrak motion capturing system was used to detect relative motion of the three fracture fragments at eight different points along the fracture lines. Horizontal separation and vertical displacement at the fracture lines was recorded, as well as relative rotation at the primary fracture line. When the data were averaged, there was more horizontal displacement at the primary fracture line of the plate and screw construct compared to the headless screw construct. The headless screw construct also had less vertical displacement at the primary fracture line at every load. On average those fractures fixed with the headless screw technique had less rotation than those fixed with the side plate technique. A new headless screw technique for calcaneus fracture fixation was shown to provide stability as good as, or better than, a standard side plating technique under the axial loading conditions of our model. Although further testing is needed, the stability of the proposed technique is similar to that typically provided by intramedullary fixation. This fixation technique provides a biomechanically stable construct with the potential for a minimally invasive approach and improved post-operative soft tissue healing.
Removable partial overdentures with natural root structure and osseointegrated fixtures.
Jackson, T R
1990-10-01
The development and refinement of osseointegration have had primary impetus in treatment of the totally edentulous patient. The same principles, however, may be applied to the partially edentulous patient. Osseointegrated fixtures used in conjunction with mechanical or magnetic attachments may be used to construct partial or full overdentures. This allows treatment with removable prosthodontics in many cases in which it is not practical to achieve anchorage for a fixed prosthesis.
RadVel: The Radial Velocity Modeling Toolkit
NASA Astrophysics Data System (ADS)
Fulton, Benjamin J.; Petigura, Erik A.; Blunt, Sarah; Sinukoff, Evan
2018-04-01
RadVel is an open-source Python package for modeling Keplerian orbits in radial velocity (RV) timeseries. RadVel provides a convenient framework to fit RVs using maximum a posteriori optimization and to compute robust confidence intervals by sampling the posterior probability density via Markov Chain Monte Carlo (MCMC). RadVel allows users to float or fix parameters, impose priors, and perform Bayesian model comparison. We have implemented real-time MCMC convergence tests to ensure adequate sampling of the posterior. RadVel can output a number of publication-quality plots and tables. Users may interface with RadVel through a convenient command-line interface or directly from Python. The code is object-oriented and thus naturally extensible. We encourage contributions from the community. Documentation is available at http://radvel.readthedocs.io.
Altinci, Pinar; Can, Gulsen; Gunes, Onur; Ozturk, Caner; Eren, Hakan
2016-12-01
Immediately-loaded, narrow-diameter implants can be a less invasive alternative for the implant-supported fixed rehabilitation of narrow, posterior crests. To determine the stability and marginal bone level (MBL) changes of narrow-diameter, titanium-zirconium (TiZr) implants placed with flapless surgery and loaded immediately in the posterior region. Thirty-eight TiZr implants (3.3 mm diameter, 10 mm length, Roxolid, Straumann AG) were placed in the posterior crests of 14 patients with computer-guided flapless surgery as a support of 3-unit posterior bridges. Eighteen implants were loaded immediately, and 20 implants were loaded conventionally. The implant stability quotients were determined at the 1, 2, 4, and 8. weeks of healing before conventional loading, and at the 3, 6, and 12. months after loading by resonance frequency analysis. The MBL changes were measured by digital radiography. The surgical protocols were accomplished without any biological complications. There was no significant difference in the stability changes of TiZr implants between the loading groups (p > .05). The MBL changes were -0.18 ± 0.27 mm and -0.24 ± 0.27 mm at the 12. month of immediate and conventional loading, respectively, which was not statistically significant (p > .05). The stability and MBL changes of TiZr implants supporting posterior 3-unit bridges were clinically acceptable at the first year of loading. © 2016 Wiley Periodicals, Inc.
Lin, Haodong; Hou, Chunlin; Chen, Aimin; Xu, Zhen
2010-08-01
Among the many difficult problems presented by patients with spinal cord injuries, management of ischial pressure ulcers remains challenging for reconstructive surgeons. This study describes the long-term outcome of using posterior-thigh fasciocutaneous flaps for the treatment of ischial pressure sores. Between January 1999 and June 2003, 12 patients with ischial sores were enrolled in this study. All the patients underwent early aggressive surgical debridement followed by surgical reconstruction with a laterally based posterior-thigh fasciocutaneous flap. The follow-up period ranged from 24 months to 97 months (mean, 62 months). All the flaps survived, and there were no partial flap losses. Primary-wound healing occurred in all the cases. In two patients, Grade II ischial pressure sores recurred 24 months and 27 months after the operation. There was no recurrence in the other 10 patients. The posterior-thigh fasciocutaneous pedicled flap was a good method for treating ischial bed sores. This flap could be used to treat recurrences observed after primary bed-sore treatment with other methods. The flap was easy to raise, and it did not cause any donor-site morbidity. The long-term outcome of using posterior-thigh fasciocutaneous flaps for the treatment of ischial pressure sores was generally good. (c) Thieme Medical Publishers.
Detecting interaction in chemical mixtures can be complicated by differences in the shapes of the dose-response curves of the individual components (e.g. mixtures of full and partial agonists with differing response maxima). We present an analysis scheme where flexible single che...
Yoon, Hyung-In
2016-10-01
This report is to present the treatment procedure and clinical considerations of prosthodontic management of a patient who had undergone a partial mandibulectomy and fibular free flap surgery. A 59-year-old man with a squamous cell carcinoma received a partial mandibular resection. Microsurgical reconstruction with a fibular free flap surgery and implant-supported zirconia-fixed prosthesis produced by computer-aided manufacturing led to successful results for the oral rehabilitation of mandibular defects. The implant-supported zirconia-fixed prosthesis can be recommended for use in patients with mandibulectomy and fibular free flaps. Close cooperation between the surgeon and the prosthodontist is mandatory for the satisfaction of the patient.
Effects of fixed functional therapy on tongue and hyoid positions and posterior airway.
Ozdemir, Fulya; Ulkur, Feyza; Nalbantgil, Didem
2014-03-01
To evaluate how therapy with a fixed functional appliance affects airway dimensions, dentoalveolar changes, and tongue and hyoid positions. A retrospective study was carried out on 46 pre- and posttreatment lateral cephalometric radiographs of 23 post-peak Class II patients (12 girls, 11 boys) treated with a Forsus Fatigue Resistant Device (FRD) appliance. The radiographies were taken at the start and at the end of Forsus FRD appliance therapy when a Class I or overcorrected Class I canine and molar relationship was achieved. The process took an average of 5 months 13 days ± 1 month 4 days. Skeletal and dental parameters were measured using Dolphin software, and the sagittal airway area was measured by AutoCAD software. Analyses of the pre- and posttreatment means revealed that there was no statistically significant skeletal correction of the sagittal malocclusion; increase of lower incisor inclination, decrease of upper incisor inclination, decrease of interincisal angle, and rotation of occlusal plane all contributed to the reduction of overjet. The tongue area and intermaxillary space area increased in response to these dentoalveolar changes; however, there was no statistically significant change in the hyoid position or the oropharyngeal area between the two time points. The dentoalveolar changes produced by Forsus FRD appliance did not cause any significant posterior airway changes in young adult patients.
Nonparametric estimation and testing of fixed effects panel data models
Henderson, Daniel J.; Carroll, Raymond J.; Li, Qi
2009-01-01
In this paper we consider the problem of estimating nonparametric panel data models with fixed effects. We introduce an iterative nonparametric kernel estimator. We also extend the estimation method to the case of a semiparametric partially linear fixed effects model. To determine whether a parametric, semiparametric or nonparametric model is appropriate, we propose test statistics to test between the three alternatives in practice. We further propose a test statistic for testing the null hypothesis of random effects against fixed effects in a nonparametric panel data regression model. Simulations are used to examine the finite sample performance of the proposed estimators and the test statistics. PMID:19444335
Targeted traction of impacted teeth with C-tube miniplates.
Chung, Kyu-Rhim; Kim, Yong; Ahn, Hyo-Won; Lee, Dongjoo; Yang, Dong-Min; Kim, Seong-Hun; Nelson, Gerald
2014-09-01
Orthodontic traction of impacted teeth has typically been performed using full fixed appliance as anchorage against the traction force. This conventional approach can be difficult to apply in the mixed dentition if the partial fixed appliance offers an insufficient anchor unit. In addition, full fixed appliance can induce unwanted movement of adjacent teeth. This clinical report presents 3 cases where impacted teeth were recovered in the mixed or transitional dentition with skeletal anchorage on the opposite arch without full fixed appliance. Instead, intermaxillary traction was used to bring the impacted teeth into position. With this approach, side effects on teeth and periodontal tissues adjacent to the impaction were minimized.
Anwar, Adeel; Lv, Decheng; Zhao, Zhi; Zhang, Zhen; Lu, Ming; Nazir, Muhammad Umar; Qasim, Wasim
2017-04-01
Appropriate fixation method for the posterior malleolar fractures (PMF) according to the fracture size is still not clear. Aim of this study was to evaluate the outcomes of the different fixation methods used for fixation of PMF by finite element analysis (FEA) and to compare the effect of fixation constructs on the size of the fracture computationally. Three dimensional model of the tibia was reconstructed from computed tomography (CT) images. PMF of 30%, 40% and 50% fragment sizes were simulated through computational processing. Two antero-posterior (AP) lag screws, two postero-anterior (PA) lag screws and posterior buttress plate were analysed for three different fracture volumes. The simulated loads of 350N and 700N were applied to the proximal tibial end. Models were fixed distally in all degrees of freedom. In single limb standing condition, the posterior plate group produced the lowest relative displacement (RD) among all the groups (0.01, 0.03 and 0.06mm). Further nodal analysis of the highest RD fracture group showed a higher mean displacement of 4.77mm and 4.23mm in AP and PA lag screws model (p=0.000). The amounts of stress subjected to these implants, 134.36MPa and 140.75MPa were also significantly lower (p=0.000). There was a negative correlation (p=0.021) between implant stress and the displacement which signifies a less stable fixation using AP and PA lag screws. Progressively increasing fracture size demands more stable fixation construct because RD increases significantly. Posterior buttress plate produces superior stability and lowest RD in PMF models irrespective of the fragment size. Copyright © 2017 Elsevier Ltd. All rights reserved.
Okabe, Y; Takeuchi, K; Izumi, M; Furuta, M; Takeshita, T; Shibata, Y; Kageyama, S; Ganaha, S; Yamashita, Y
2017-02-01
The total number of natural teeth was related to swallowing function among older adults; however, limited information is available regarding the impact of occluding pairs of teeth on swallowing function. This study aimed to examine the association between posterior teeth occlusion and dysphagia risk in older nursing home residents. This cross-sectional study included 238 residents aged ≥60 years from eight nursing homes in Aso City, Japan. Swallowing function was evaluated using the modified water swallowing test (MWST); the primary outcome was dysphagia risk (MWST score ≤3). Posterior teeth occlusion was assessed using number of functional tooth units (FTUs), determined based on number and location of the remaining natural and artificial teeth on implant-supported, fixed or removable prostheses. Univariate and multivariate logistic regression analyses were performed to examine the association between posterior teeth occlusion and dysphagia risk, adjusted for the covariates of number of natural teeth, demographic characteristics, comorbidities, physical function, body mass index and cognitive function. Of the 238 subjects, 44 (18·5%) were determined to be at risk of dysphagia based on the MWST scores. The odds ratio (OR) of dysphagia risk decreased in subjects with higher total FTUs [OR = 0·92, 95% confidence interval (CI) 0·87-0·98]. After adjusting for covariates, this association remained significant (OR = 0·90, 95% CI 0·84-0·97). Loss of posterior teeth occlusion was independently associated with dysphagia risk in older nursing home residents. Maintaining and restoring posterior teeth occlusion may be an effective measure to prevent dysphagia. © 2016 John Wiley & Sons Ltd.
Cerebellar development in childhood onset schizophrenia and non-psychotic siblings
Greenstein, Deanna; Lenroot, Rhoshel; Clausen, Liv; Gogtay, Nitin; Rapoport, Judith
2011-01-01
We explored regional and total volumetric cerebellar differences in probands and their unaffected full siblings relative to typically developing participants. Participants included 94 (51 males) patients diagnosed with childhood onset schizophrenia (COS), 80 related non-psychotic siblings (37 males) and 110 (64 males) typically developing participants scanned longitudinally. The sample mean age was 16.87(SD=4.7; range 6.5 to 29). We performed mixed model regressions to examine group differences in trajectory and volume. The COS group had smaller bilateral anterior lobes and anterior and total vermis volumes than controls. The COS group diverged from controls over time in total, left, right, and bilateral posterior inferior cerebellum. Siblings did not have any fixed volumetric differences relative to controls but differed from controls in developmental trajectories of total and right cerebellum, left inferior posterior, left superior posterior, and superior vermis. Results are consistent with previous COS findings and several reports of decreased cerebellar volume in adult onset schizophrenia. Sibling trajectories may represent a trait marker, although the effect size for volumetric differences in early adulthood may be small. PMID:21803550
Palatoplasty: suturing the mucoperiosteal flaps to the hard palate through hole.
Hwang, Kun; Lee, Ji Hun; Kim, Yu Jin; Le, Se Il
2009-05-01
We satisfactorily repaired a wide cleft palate using a method of V-Y pushback and anchoring the oral mucoperiosteal flap onto the bony ridge of the cleft. An 8-year-old Vietnamese girl had a wide incomplete bilateral posterior cleft palate associated with congenital cardiac malformations. The gap of the posterior cleft was 2.5 cm, which exceeded the total widths of the palatal shelves. We applied V-Y pushback and used a vomer flap to close the wide cleft palate. The posterior two thirds of the nasal mucosae from the cleft margins were sutured to the vomer flap. The nasal side of the anterior one third of the bony cleft was uncovered. The elevated bilateral mucoperiosteal flaps were brought together to the midline and sutured to the anterior triangular flap in a V-Y pushback fashion. Four holes were drilled 5 mm lateral to each bony cleft margin. The lateral sides of the mucoperiosteal flaps were fixed to the palate bone with 3-0 Vicryl through the hole. This method reduces the tension of the flap which might frequently cause oronasal fistula and also improve viability.
Chen, Xiwen; Zhang, Yixin; Zhou, Jinru; Chen, Chenfeng; Zhu, Zhimin; Li, Lei
2018-01-01
The aim of this study was to investigate the adhesive property of palladium-silver alloy (Pd-Ag) and the simulated clinical performance of Pd-Ag porcelain-fused-to-metal (PFM), resin-bonded, fixed partial dentures (RBFPDs). A total of 40 Pd-Ag discs (diameter=5 mm) were prepared and divided into the following four groups (n=10): a) No sandblasting, used as a control; and b, 50 µm; c, 110 µm; and d, 250 µm aluminum oxide (Al2O3) particles, respectively. Another 50 discs were pre-sandblasted and divided into five groups (n=10) subjected to different treatments: e) Sandblasting, used as a control; f) silane; g) alloy primer; h) silica coating + silane and i) silica coating + alloy primer. All 90 discs were bonded to enamel with Panavia F 2.0 and then subjected to shear bond strength (SBS) testing. The fracture surfaces were examined by scanning electron microscopy. Next, 40 missing maxillary second premolar models were restored with one of the four following RBFPD designs (n=10): I) A premolar occlusal bar combined with molar double rests (MDR); II) both occlusal bars with a wing (OBB); III) a premolar occlusal bar combined with a molar dental band (MDB); and IV) two single rests adjacent to the edentulous space with a wing (SRB) used as a control. All specimens were aged with thermal cycling and mechanical loading. Subsequently, they were loaded until broken. The data were analyzed by one-way analysis of variance. Al2O3 (250 µm) abrasion provided the highest SBS (P<0.05). The alloy primer and silica + silane exhibited increased SBS. Furthermore, fracture analysis revealed that the failure mode varied among the different treatments. Whereas MDB exhibited the highest retention (P<0.05), that of OBB was greater than that of MDR (P<0.05), and the control exhibited the lowest retention. Abrasion with Al2O3 (250 µm) effectively increased the adhesive property of Pd-Ag. Additionally, treatment with the alloy primer and silica coating + silane was able to increase the adhesive property of abraded Pd-Ag. Under the present conditions, all three modified retainer types provided improved outcomes for Pd-Ag PFM RBFPDs compared with the control. PMID:29434797
Identification of dynamic load for prosthetic structures.
Zhang, Dequan; Han, Xu; Zhang, Zhongpu; Liu, Jie; Jiang, Chao; Yoda, Nobuhiro; Meng, Xianghua; Li, Qing
2017-12-01
Dynamic load exists in numerous biomechanical systems, and its identification signifies a critical issue for characterizing dynamic behaviors and studying biomechanical consequence of the systems. This study aims to identify dynamic load in the dental prosthetic structures, namely, 3-unit implant-supported fixed partial denture (I-FPD) and teeth-supported fixed partial denture. The 3-dimensional finite element models were constructed through specific patient's computerized tomography images. A forward algorithm and regularization technique were developed for identifying dynamic load. To verify the effectiveness of the identification method proposed, the I-FPD and teeth-supported fixed partial denture structures were investigated to determine the dynamic loads. For validating the results of inverse identification, an experimental force-measuring system was developed by using a 3-dimensional piezoelectric transducer to measure the dynamic load in the I-FPD structure in vivo. The computationally identified loads were presented with different noise levels to determine their influence on the identification accuracy. The errors between the measured load and identified counterpart were calculated for evaluating the practical applicability of the proposed procedure in biomechanical engineering. This study is expected to serve as a demonstrative role in identifying dynamic loading in biomedical systems, where a direct in vivo measurement may be rather demanding in some areas of interest clinically. Copyright © 2017 John Wiley & Sons, Ltd.
Underworld results as a triple (shopping list, posterior, priors)
NASA Astrophysics Data System (ADS)
Quenette, S. M.; Moresi, L. N.; Abramson, D.
2013-12-01
When studying long-term lithosphere deformation and other such large-scale, spatially distinct and behaviour rich problems, there is a natural trade-off between the meaning of a model, the observations used to validate the model and the ability to compute over this space. For example, many models of varying lithologies, rheological properties and underlying physics may reasonably match (or not match) observables. To compound this problem, each realisation is computationally intensive, requiring high resolution, algorithm tuning and code tuning to contemporary computer hardware. It is often intractable to use sampling based assimilation methods, but with better optimisation, the window of tractability becomes wider. The ultimate goal is to find a sweet-spot where a formal assimilation method is used, and where a model affines to observations. Its natural to think of this as an inverse problem, in which the underlying physics may be fixed and the rheological properties and possibly the lithologies themselves are unknown. What happens when we push this approach and treat some portion of the underlying physics as an unknown? At its extreme this is an intractable problem. However, there is an analogy here with how we develop software for these scientific problems. What happens when we treat the changing part of a largely complete code as an unknown, where the changes are working towards this sweet-spot? When posed as a Bayesian inverse problem the result is a triple - the model changes, the real priors and the real posterior. Not only does this give meaning to the process by which a code changes, it forms a mathematical bridge from an inverse problem to compiler optimisations given such changes. As a stepping stone example we show a regional scale heat flow model with constraining observations, and the inverse process including increasingly complexity in the software. The implementation uses Underworld-GT (Underworld plus research extras to import geology and export geothermic measures, etc). Underworld uses StGermain an early (partial) implementation of the theories described here.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frame, C; Ding, G
Purpose: To quantify patient setups errors based on bony anatomy registration rather than 3D tumor alignment for SBRT lung treatments. Method: A retrospective study was performed for patients treated with lung SBRT and imaged with kV cone beam computed tomography (kV-CBCT) image-guidance. Daily CBCT images were registered to treatment planning CTs based on bony anatomy alignment and then inter-fraction tumor movement was evaluated by comparing shift in the tumor center in the medial-lateral, anterior-posterior, and superior-inferior directions. The PTV V100% was evaluated for each patient based on the average daily tumor displacement to assess the impact of the positioning errormore » on the target coverage when the registrations were based on bony anatomy. Of the 35 patients studied, 15 were free-breathing treatments, 10 used abdominal compression with a stereotactic body frame, and the remaining 10 were performed with BodyFIX vacuum bags. Results: For free-breathing treatments, the range of tumor displacement error is between 1–6 mm in the medial-lateral, 1–13 mm in the anterior-posterior, and 1–7 mm in the superior-inferior directions. These positioning errors lead to 6–22% underdose coverage for PTV - V100% . Patients treated with abdominal compression immobilization showed positional errors of 0–4mm mediallaterally, 0–3mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% underdose ranging between 6–17%. For patients immobilized with the vacuum bags, the positional errors were found to be 0–1 mm medial-laterally, 0–1mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% under dose ranging between 5–6% only. Conclusion: It is necessary to align the tumor target by using 3D image guidance to ensure adequate tumor coverage before performing SBRT lung treatments. The BodyFIX vacuum bag immobilization method has the least positioning errors among the three methods studied when bony anatomy is used for registration.« less
The treatment options for posterior malleolar fractures in tibial spiral fractures.
Guo, Jialiang; Liu, Lei; Yang, Zongyou; Hou, Zhiyong; Chen, Wei; Zhang, Yingze
2017-09-01
The posterior malleolar fracture (PMF) in tibial spiral fractures are a common type of complication that occurs in tibial fractures. However, the indication of fixation for posterior fractures is still under debate and varies between different surgeons'. It is not unusual to find the smaller PMF (<25%), which could be treated conservatively within guidelines, treated with internal fixation in clinic. The aim of this study is to evaluate the clinical outcomes of tibial spiral fractures with PMF and provide proper guidance for the treatment of this special fracture. A total of 284 cases of spiral fractures combined with PMF were collected and analyzed. Demographic data, fragment size (classified by 25% involvement of ankle joint), time to weight-bearing and functional scores post-operatively were recorded. The ankle-hindfoot scale of the American Orthopaedic Foot and Ankle Society (AOFAS), a visual analogue scale (VAS) pain score, assessment of dorsiflexion restriction and arthritis scale were used as the main evaluations. Forty patients with a larger PMF (≥25%) and 72 with smaller ones (<25%) were fixed and categorized as the fixation group (FG). In the nonfixation group (NG), the corresponding numbers were four and 168 patients respectively. A total of 279 PMF were classified as large posterolateral triangular fragment carrying the posterior half of the fibular notch and intra-incisural posterolateral fragment involving one-fourth to one-third of the fibular notch. However, no obvious differences were observed in terms of the clinical outcomes in PMF involving one-fourth to one-third of the fibular notch. In the treatment of smaller PMF (<25%) of this type, there were no obvious differences in the functional outcomes between fixed (SF) and nonfixed PMF (SN). Many patients with smaller PMFs were fixated, but functional outcomes of SF were not better than those of SN. There is no need to emphasize other factors guiding the treatment of PMF involving one-fourth to one-third of the fibular notch in spiral fractures. The traditional size of PMF may be only enough to guide the treatment of spiral fracture with PMF. But other types of PMF should still be treated considering morphology and fragment simultaneously.
Expression of the homeotic gene mab-5 during Caenorhabditis elegans embryogenesis.
Cowing, D W; Kenyon, C
1992-10-01
mab-5 is a member of a complex of homeobox-containing genes evolutionarily related to the Antennapedia and bithorax complexes of Drosophila melanogaster. Like the homeotic genes in Drosophila, mab-5 is required in a particular region along the anterior-posterior body axis, and acts during postembryonic development to give cells in this region their characteristic identities. We have used a mab-5-lacZ fusion integrated into the C. elegans genome to study the posterior-specific expression of mab-5 during embryogenesis. The mab-5-lacZ fusion was expressed in the posterior of the embryo by 180 minutes after the first cleavage, indicating that the mechanisms responsible for the position-specific expression of mab-5-lacZ act at a relatively early stage of embryogenesis. In embryos homozygous for mutations in the par genes, which disrupt segregation of factors during early cleavages, expression of mab-5-lacZ was no longer localized to the posterior. This suggests that posterior-specific expression of mab-5 depends on the appropriate segregation of developmental factors during early embryogenesis. After extrusion of any blastomere of the four-cell embryo, descendants of the remaining three cells could still express the mab-5-lacZ fusion. In these partial embryos, however, the fusion was often expressed in cells scattered throughout the embryo, suggesting that cell-cell interactions and/or proper positioning of early blastomeres are required for mab-5 expression to be localized to the posterior.
Maló, Paulo; de Araújo Nobre, Miguel; Lopes, Armando
2016-07-01
The aim of this prospective clinical study was to evaluate the 3-year outcome of fixed partial prostheses supported by implants with immediate provisionalization without occlusal contacts inserted in predominantly soft bone with flap and flapless protocols. Forty-one patients partially rehabilitated with 72 NobelSpeedy implants (51 maxillary; 21 mandibular) were consecutively included and treated with a flapless surgical protocol (n = 20 patients; 32 implants) and flapped surgical protocol (n = 21 patients; 40 implants). Primary outcome measure was implant survival; secondary outcome measures were marginal bone resorption (comparing the bone levels at 1 and 3 years with baseline) and the incidence of biological, mechanical, and esthetic complications. Survival was computed through life tables; descriptive statistics were applied to the remaining variables of interest. Eight patients with eight implants dropped out of the study. One implant failed in one patient (flapless group) giving an overall cumulative survival rate (CSR) of 98.6%. No failures were noted with the flapped protocol (CSR 100%), while for the implants placed with the flapless surgical technique, a 96.9% CSR was registered. The overall average marginal bone resorption at 3 years was 1.37 mm (SD = 0.94 mm), with 1.14 mm (SD = 0.49 mm) and 1.60 mm (SD = 1.22 mm) for the flap and flapless groups, respectively. Mechanical complications occurred in nine patients (n = 5 patients in the flapless group; n = 4 patients in the flap group). Implant infection was registered in three implants and three patients (flapless group), who exhibited inadequate oral hygiene levels. Partial edentulism rehabilitation through immediate provisionalization fixed prosthesis supported by dental implants inserted through flap or flapless surgical techniques in areas of predominantly soft bone was viable at 3 years of follow-up. The limitations and risks of the "free-hand" method in flapless surgery should be considered when planning implant-supported fixed prosthetic reconstructions. © 2015 by the American College of Prosthodontists.
[Comparison of the Arthroscopic Finding in the Knee Joint and the MRI - Retrospective Study].
Šimeček, K; Látal, P; Duda, J; Šimeček, M
2017-01-01
PURPOSE OF THE STUDY Our retrospective study presents the comparison of the preoperative magnetic resonance imaging of the knee joint - MRI - and the arthroscopic finding - ASC. Its aim is to find out how a positive or a negative finding of MRI corresponds with the operative finding and how much the experience of radiologist contributes to the conformity. MATERIAL AND METHODS The MRI findings of knee joints treated surgically at two departments in 2013 and 2014 were assessed. The MRI was performed in a total of 470 patients who subsequently underwent an arthroscopic surgery. A conformity or a non-conformity in anterior, posterior horn and complete rupture of both menisci and in partial or complete tear of anterior cruciate ligament - LCA was searched for. The sensitivity, specificity and accuracy of MRI were established. The difference between experienced and less experienced radiologists was evaluated. The analysis of the radiology report, surgical protocol of ASC and medical history in the documentation was performed. The cartilage was not subject to evaluation. The finding of Grade 1 meniscus tear on MRI was evaluated as negative. Grade 2 and Grade 3 were evaluated as positive. RESULTS Comparison of the preoperative MRI and the arthroscopic finding 1. The group with MRI reported 3 % of diagnostic arthroscopies. The control group without MRI (551 ASC) reported 15 % diagnostic arthroscopies. 2. Low sensitivity of MRI (0.67) in negative findings of ASC. It concerned 7 cases in which a pathological finding was identified on a MRI scan, but not by ASC. In two cases the repeated arthroscopy confirmed that a pathology inside the knee joint was overlooked by the arthroscopist. In the remaining five cases, the clinical finding improved without a repeated surgery. 3. High sensitivity of MRI is shown in the most frequent finding - posterior horn of medial meniscus (0.94). 4. Lower sensitivity (0.76) in partial and (0.83) in complete ACL tear. It increases to 0.93 if partial and complete tear are put together. Both MRI and ASC detect the pathology of ligament, but do not agree in terms of terminology. 5. Lower sensitivity (0.78) was seen in posterior horn of lateral meniscus, most likely due to its complicated anatomy. 6. Specificity of complete tear of medial meniscus tear is 0.99. Lower specificity in the posterior horn of medial meniscus (0.81) shows a higher number of positive MRI findings in negative ASC findings. Some posterior horn tear can be overlooked by an inexperienced surgeon. The MRD findings need to be studied. 7. High specificity (0.99) was described in negative findings. In three cases only, the surgeon discovered a pathological finding, not revealed by MRI scan. It always concerned a tear within the posterior horn of the medial meniscus. 8. Specificity (0.88, 0.93 or 0.86, respectively) in partial, complete and all ACL damages in total. 9. We concluded that contributing to the degree of agreement between MRI and ASC is also the experience of a radiologist. The most experienced radiologist evaluated 190 of 470 MRI scans, the remaining twelve radiologists assessed 280 scans. The posterior horn of the medial meniscus - sensitivity or specificity evaluated by an experienced radiologist (0.98 and 0.88, respectively) and inexperienced radiologist (0.91 and 0.79). The specificity and sensitivity in complete ACL tears - by experienced radiologist (0.91 and 0.94, respectively) and inexperienced radiologist (0.81 and 0.90, respectively). The test accuracy of the experienced radiologist in evaluating the most frequent injuries of soft knee structures was by 9-10 % higher than of the inexperienced radiologist. DISCUSSION The results obtained by the other authors show that the sensitivity and specificity range from 0.6 to 0.9. They agree that the MRI is unsuitable for assessing the cartilage. We confirm that the results are worse when evaluating the posterior horn of the lateral meniscus. We have also proven that the radiologist s experience does play an important role. It can be the reason for a high degree of difference between the results of various authors. Some of them give preference to a clinical examination or a diagnostic arthroscopy instead of the MRI. At our department, MRI is indicated if we are convinced it can help with the indication or where it will suggest what to focus on during the surgery. CONCLUSIONS A preoperative MRI scan can prevent an unnecessary arthroscopy. It displays structures to the surgeon which shall be reviewed in detail during the surgery. We recommend paying attention to Grade 2 MRI findings, positive MRI findings on the posterior horn of medial meniscus and to MRI findings on partial ACL tears. Such menisci and ligaments shall be carefully reviewed. Clinical preoperative examination and cooperation between the surgeon, the "arthroscopist", and the radiologist is essential. The experience of the radiologist also plays a role when evaluating the MRI scan. We have introduced MRI ward rounds. Key words: MRI, knee joint, knee arthroscopy, sensitivity, specificity, accuracy.
Meta-analysis of posterior versus medial approach for popliteal artery aneurysm repair.
Phair, Alison; Hajibandeh, Shahin; Hajibandeh, Shahab; Kelleher, Damian; Ibrahim, Riza; Antoniou, George A
2016-10-01
Popliteal artery aneurysm is an uncommon vascular disease but one that can cause significant morbidity, the most severe being limb loss reported in 20% to 59% of cases. Two approaches to repair are described in the literature, the posterior and the medial; however, the "gold standard" method of repair remains controversial. A systematic review of electronic information sources was undertaken to identify papers comparing outcomes of posterior repair vs medial repair. The methodologic quality of the papers was assessed using the Newcastle-Ottawa Scale. Fixed-effect or random-effects models were applied to synthesize data. The search yielded seven articles eligible for inclusion. The total population comprised 1427 patients; 338 had posterior repair and 1089 had medial repair. There was no difference in the two groups in terms of postoperative nerve damage (odds ratio [OR], 1.01; 95% confidence interval [CI], 0.24-4.2) and 30-day postoperative complications (OR, 0.87; 95% CI, 0.43-1.77). Limb loss at 30 days occurred more frequently in the medial approach group, but the difference was not statistically significant (risk difference [RD], 0.02; 95% CI, -0.04 to 0.00). Thirty-day primary patency was not statistically different between groups (RD, -0.01; 95% CI, -0.04 to 0.02), but the 30-day secondary patency suggested superiority of the posterior approach (RD, 0.05; 95% CI, 0.02-0.07). Long-term primary and secondary patency both favored the posterior approach (OR, 1.61 [95% CI, 1.06-2.43] and OR, 1.73 [95% CI, 0.91-3.30], respectively). Aneurysm exclusion was also superior with the posterior approach (OR, 4.20; 95% CI, 1.40-12.60). The rate of reoperation favored the posterior approach (OR, 0.26; 95% CI, 0.09-0.72). Long-term risk of limb loss favored posterior repair, but no statistically significant difference was found (OR, 0.32; 95% CI, 0.43-1.77). High-level comparative data comparing posterior and medial repair for popliteal artery aneurysms are not available. Within the parameters of this review, however, superiority of the posterior approach for primary and secondary patency, aneurysm exclusion, and need for reoperation was noted. High-level evidence from randomized clinical trials is required to define the relative benefits of the posterior approach over the medial approach in selected patients. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Applying Bayesian Item Selection Approaches to Adaptive Tests Using Polytomous Items
ERIC Educational Resources Information Center
Penfield, Randall D.
2006-01-01
This study applied the maximum expected information (MEI) and the maximum posterior-weighted information (MPI) approaches of computer adaptive testing item selection to the case of a test using polytomous items following the partial credit model. The MEI and MPI approaches are described. A simulation study compared the efficiency of ability…
Topics in inference and decision-making with partial knowledge
NASA Technical Reports Server (NTRS)
Safavian, S. Rasoul; Landgrebe, David
1990-01-01
Two essential elements needed in the process of inference and decision-making are prior probabilities and likelihood functions. When both of these components are known accurately and precisely, the Bayesian approach provides a consistent and coherent solution to the problems of inference and decision-making. In many situations, however, either one or both of the above components may not be known, or at least may not be known precisely. This problem of partial knowledge about prior probabilities and likelihood functions is addressed. There are at least two ways to cope with this lack of precise knowledge: robust methods, and interval-valued methods. First, ways of modeling imprecision and indeterminacies in prior probabilities and likelihood functions are examined; then how imprecision in the above components carries over to the posterior probabilities is examined. Finally, the problem of decision making with imprecise posterior probabilities and the consequences of such actions are addressed. Application areas where the above problems may occur are in statistical pattern recognition problems, for example, the problem of classification of high-dimensional multispectral remote sensing image data.
Li, Bei Bei; Xu, Jia Bin; Cui, Hong Yan; Lin, Ye; Di, Ping
2016-01-01
The aim of this study was to assess the effects of partial carbon or glass fiber reinforcement on the flexural properties of All-on-Four provisional fixed denture base resin. The carbon or glass fibers were woven (3% by weight) together in three strands and twisted and tightened between the two abutments in a figure-of-"8" pattern. Four types of specimens were fabricated for the three-point loading test. The interface between the denture base resin and fibers was examined using scanning electron microscopy (SEM). Reinforcement with carbon or glass fibers between two abutments significantly increased the flexural strength and flexural modulus. SEM revealed relatively continuous contact between the fibers and acrylic resin. The addition of carbon or glass fibers between two abutments placed on All-on-Four provisional fixed denture base resin may be clinically effective in preventing All-on-Four denture fracture and can provide several advantages for clinical use.
Kinetic Modeling of the Reaction Rate for Quartz and Carbon Black Pellet
NASA Astrophysics Data System (ADS)
Li, Fei; Tangstad, Merete
2018-06-01
The kinetic modeling for the carbothermal reduction reaction rate in quartz and carbon black pellets is studied at different temperatures, under varying CO partial pressures in ambient atmosphere, varying carbon contents, different quartz particle sizes, and different crucible opening areas. Carbon black is produced by the cracking of natural gas. The activation energy of the SiC-producing step was determined to be 594 kJ/mol. The averaged pre-exponential factor A obtained from 1898 K, 1923 K, and 1948 K (1625 °C, 1650 °C, and 1675 °C) is 2.62E+16 min-1. The reaction rate of the gas-solid interface factor, fix-C content ( X fix-C), temperature ( T), and CO partial pressure ( X CO) can be expressed as follows: {{d/pct}}{{{d}t}} = (1 - 0.40 × X_{{{fix} - C}}^{ - 0.86} × {pct}) × 2.62 × 10^{16} × \\exp ( { - 594000/RT} ) × (2.6 - 0.015 × X_{co} ).
Park, Do Young; Min, Byoung-Hyun; Choi, Byung Hyune; Kim, Young Jick; Kim, Mijin; Suh-Kim, Haeyoung; Kim, Joon Ho
2015-12-01
Fibrocartilage metaplasia in tendons and ligaments is an adaptation to compression as well as a pathological feature during degeneration. Medial meniscus posterior roots are unique ligaments that resist multidirectional forces, including compression. To characterize the degeneration of medial meniscus posterior root tears in osteoarthritic knees, with an emphasis on fibrocartilage and calcification. Cross-sectional study; Level of evidence, 3. Samples of medial meniscus posterior roots were harvested from cadaveric specimens and patients during knee replacement surgery and grouped as follows: normal reference, no tear, partial tear, and complete tear. Degeneration was analyzed with histology, immunohistochemistry, and real-time polymerase chain reaction. Uniaxial tensile tests were performed on specimens with and without fibrocartilage. Quantifiable data were statistically analyzed by the Kruskal-Wallis test with the Dunn comparison test. Thirty, 28, and 42 samples harvested from 99 patients were allocated into the no tear, partial tear, and complete tear groups, respectively. Mean modified Bonar tendinopathy scores for each group were 3.97, 9.31, and 14.15, respectively, showing a higher degree of degeneration associated with the extent of the tear (P < .05 for all groups). The characterization of root matrices revealed an increase in fibrocartilage according to the extent of the tear. Tear margins revealed fibrocartilage in 59.3% of partial tear samples and 76.2% of complete tear samples, with a distinctive cleavage-like shape. Root tears with a similar shape were induced within fibrocartilaginous areas during uniaxial tensile testing. Even in the no tear group, 56.7% of samples showed fibrocartilage in the anterior margin of the root, adjacent to the meniscus. An increased stained area of calcification and expression of the ectonucleotide pyrophosphatase/phosphodiesterase 1 gene were observed in the complete tear group compared with the no tear group (P < .0001 and P = .24, respectively). Fibrocartilage and calcification increased in medial meniscus posterior roots, associated with the degree of the tear. Both findings, which impair the ligament's resistance to tension, may play a pivotal role during the pathogenesis of degenerative meniscus root tears in osteoarthritic knees. Fibrocartilage and calcification may be useful as diagnostic markers as well as markers of degeneration, which may aid in determining the treatment modality in meniscus root tears. The presence of fibrocartilage in intact roots may suggest an impending tear in osteoarthritic knees. © 2015 The Author(s).
NASA Astrophysics Data System (ADS)
Schoups, G.; Vrugt, J. A.; Fenicia, F.; van de Giesen, N. C.
2010-10-01
Conceptual rainfall-runoff models have traditionally been applied without paying much attention to numerical errors induced by temporal integration of water balance dynamics. Reliance on first-order, explicit, fixed-step integration methods leads to computationally cheap simulation models that are easy to implement. Computational speed is especially desirable for estimating parameter and predictive uncertainty using Markov chain Monte Carlo (MCMC) methods. Confirming earlier work of Kavetski et al. (2003), we show here that the computational speed of first-order, explicit, fixed-step integration methods comes at a cost: for a case study with a spatially lumped conceptual rainfall-runoff model, it introduces artificial bimodality in the marginal posterior parameter distributions, which is not present in numerically accurate implementations of the same model. The resulting effects on MCMC simulation include (1) inconsistent estimates of posterior parameter and predictive distributions, (2) poor performance and slow convergence of the MCMC algorithm, and (3) unreliable convergence diagnosis using the Gelman-Rubin statistic. We studied several alternative numerical implementations to remedy these problems, including various adaptive-step finite difference schemes and an operator splitting method. Our results show that adaptive-step, second-order methods, based on either explicit finite differencing or operator splitting with analytical integration, provide the best alternative for accurate and efficient MCMC simulation. Fixed-step or adaptive-step implicit methods may also be used for increased accuracy, but they cannot match the efficiency of adaptive-step explicit finite differencing or operator splitting. Of the latter two, explicit finite differencing is more generally applicable and is preferred if the individual hydrologic flux laws cannot be integrated analytically, as the splitting method then loses its advantage.
Gerald W. Krantz; John Moser
2012-01-01
Adults and nymphs of a new genus and species of the family Macrochelidae are described from detritus cavities of the leaf-cutting ant, Atta texana. This new species is notable in having peritremes with no posterior loop, a series of small subterminal teeth on the fixed cheliceral digit rather than the single large tooth typical of other macrochelids...
Endoscopic laser arytenoidectomy with the use of CO2 laser
NASA Astrophysics Data System (ADS)
Malandrakis, S.; Prokopakis, E. P.; Sidoris, M.; Karatzanis, A.; Velegrakis, G.; Helidonis, Emmanuel S.
2004-06-01
Upper airway obstruction due to bilateral vocal cord paralysis presents a serious challenge to the Otolaryngologist. Various surgical techniques have been advocated for the management of patients with vocal cord patients with vocal cord paralysis. Among these techniques, the individual use of laser CO2 arytenoidectomy and posterior cordotomy has gained wide acceptance. In this report, we describe our experience in the management of bilateral vocal cord paralysis by combining posterior partial cordotomy as described by Dennis and Kashima with total arytenoidectomy as described by Ossoff. We report the long term results in the management of 24 patients with bilateral vocal cord paralysis treated in our Department during the last 9 years.
Intrapartum sonographic imaging of fetal head asynclitism.
Ghi, T; Youssef, A; Pilu, G; Malvasi, A; Ragusa, A
2012-02-01
Anterior asynclitism was suspected on digital examination of a laboring woman with late arrest of dilatation and no evidence of fetal head progression. Clinical examination revealed a fixed non-engaged fetal head (station −1), with a transverse posterior sagittal suture. A static three-dimensional volume was obtained by translabial ultrasound, offline analysis of which confirmed the clinical diagnosis of anterior asynclitism. Owing to the posterior twisting of the head towards the sacrum, the midline echo could only be obtained by cutting the volume with an oblique line, the direction of which was not perpendicular to the pubis as expected in cases of synclitic head. The sonographic appearance of the midline echo approaching the sacrum in a non-engaged transverse fetal head strongly supports the clinical suspicion of anterior asynclitism. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.
Liu, Yu-jie; Wang, Jun-liang; Li, Hai-feng; Qi, Wei; Wang, Ning
2012-07-17
To evaluate the efficacies of arthroscopic debridement and removal of osteophyma for olecroanon and olecranon fossa plasty for posterior impingement of elbow joint. Between 1999 and 2008, a total of 21 cases were diagnosed with osteoarthritis and posterior elbow impingement. There were 15 males and 6 females. And there were 16 right and 15 left cases. They included volleyball players (n = 7), tennis players (n = 7), golf enthusiasts (n = 4) and fencers (n = 3). The average duration of onset-operation was 3.5 years (range: 2.5 - 8). Arthroscopic exploration revealed synovial hyperplasia hypertrophy, cartilage degeneration and olecranon fossa hyperplasia with deformed olecranon fossa. Debridement and plasty were performed. Loose bodies were removed from elbow joint in 6 patients. Partial resection of posterior olecranon tip was performed and osteophytes or fibrous tissue removed in this area. Dynamic observation showed no posterior elbow impingement. Postoperative follow-up was conducted in 19 cases and 2 cases became lost to follow-up. The average follow-up period was 25.3 months (range: 18 - 42). All patients were evaluated preoperatively and postoperatively with the Hospital for Special Surgery Elbow Assessment Scale. The outcomes were excellent (n = 12), good (n = 7) and fair (n = 2). Postoperative patients elbow swelling and pain relieve, sports and life function returns to normal, elbow flexion and rotating mobility obviously improved. With the elbow radiological films to measure the range of motion, the average range of motion was 90.5° preoperatively and improved to 130° postoperatively. There was significant improvement in all cases. Posterior elbow impingement is caused by hyperextension trauma and elbow overuse during specific sporting activities. Arthroscopic debridement and olecroanon or olecranon fossa plasty demonstrates excellent results for posterior impingement of elbow joint.
Bidra, Avinash S
2011-08-01
Fixed implant-supported prosthesis for the edentulous maxilla has gained tremendous popularity over the years. Multiple prosthetic designs have been introduced in order to accommodate a gamut of clinical situations. Irrespective of the design, it is paramount that the esthetics imparted by the prosthesis be uncompromised. Though esthetics is subjective, a common ground exists where all its fundamental principles converge. This article reviews pertinent dental and facial esthetics literature for application of various esthetic concepts involved in diagnosis and treatment planning for an implant-supported fixed prosthesis in the edentulous maxilla. Three-dimensional esthetic analysis involves assessment of various esthetic parameters in superior-inferior, medial-lateral, and anterior-posterior dimensions. The impact of various esthetic parameters such as facial forms, facial profiles, maxillary teeth positions, maxillary teeth proportions, smile lines, lip support, gingival display, facial midline, dental midline, horizontal cant, and smile width are discussed in detail. © 2011 Wiley Periodicals, Inc.
Wong, P P; Stenberg, N E; Edgar, L
1980-03-01
A bacterium with the taxonomic characteristics of the genus Azospirillum was isolated from celluloytic N2-fixing mixed cultures. Its characteristics fit the descriptions of both Azopirillum lipoferum (Beijerinck) comb. nov. and Azospirillum brasilense sp. nov. It may be a variant strain of A. lipoferum. In mixed cultures with cellulolytic organisms, the bacterium grew and fixed N2 with cellelose as a sole source of energy and carbon. The mixed cultures used cellulose from leaves of wheat (Triticum aestivum L.), corn (Zea mays L.), and big bluestem grass (Andropogon gerardii Vitm). Microaerophilic N2-fixing bacteria of the genus Azospirillum, such as the bacterium we isolated, may be important contributors of fixed N2 in soil with partial anaerobiosis and cellulose decomposition.
Implicit Contractive Mappings in Modular Metric and Fuzzy Metric Spaces
Hussain, N.; Salimi, P.
2014-01-01
The notion of modular metric spaces being a natural generalization of classical modulars over linear spaces like Lebesgue, Orlicz, Musielak-Orlicz, Lorentz, Orlicz-Lorentz, and Calderon-Lozanovskii spaces was recently introduced. In this paper we investigate the existence of fixed points of generalized α-admissible modular contractive mappings in modular metric spaces. As applications, we derive some new fixed point theorems in partially ordered modular metric spaces, Suzuki type fixed point theorems in modular metric spaces and new fixed point theorems for integral contractions. In last section, we develop an important relation between fuzzy metric and modular metric and deduce certain new fixed point results in triangular fuzzy metric spaces. Moreover, some examples are provided here to illustrate the usability of the obtained results. PMID:25003157
Nanotherapy for posterior eye diseases.
Kaur, Indu Pal; Kakkar, Shilpa
2014-11-10
It is assumed that more than 50% of the most enfeebling ocular diseases have their origin in the posterior segment. Furthermore, most of these diseases lead to partial or complete blindness, if left untreated. After cancer, blindness is the second most dreaded disease world over. However, treatment of posterior eye diseases is more challenging than the anterior segment ailments due to a series of anatomical barriers and physiological constraints confronted for delivery to this segment. In this regard, nanostructured drug delivery systems are proposed to defy ocular barriers, target retina, and act as permeation enhancers in addition to providing a controlled release. Since an important step towards developing effective treatment strategies is to understand the course or a route a drug molecule needs to follow to reach the target site, the first part of the present review discusses various pathways available for effective delivery to and clearance from the posterior eye. Promise held by nanocarrier systems, viz. liposomes, nanoparticles, and nanoemulsion, for effective delivery and selective targeting is also discussed with illustrative examples, tables, and flowcharts. However, the applicability of these nanocarrier systems as self-administration ocular drops is still an unrealized dream which is in itself a huge technological challenge. Copyright © 2014 Elsevier B.V. All rights reserved.
Jiang, Chao; Liu, Zhenlei; Wang, Ying; Bian, Yanyan; Feng, Bin; Weng, Xisheng
2016-01-01
Although being debated for many years, the superiority of posterior cruciate-retaining (CR) total knee arthroplasty (TKA) and posterior-stabilized (PS) TKA remains controversial. We compare the knee scores, post-operative knee range of motion (ROM), radiological outcomes about knee kinematic and complications between CR TKA and PS TKA. Literature published up to August 2015 was searched in PubMed, Embase and Cochrane databases, and meta-analysis was performed using the software, Review Manager version 5.3. Totally 14 random control trials (RCTs) on this topic were included for the analysis, which showed that PS and CR TKA had no significant difference in Knee Society knee Score (KSS), pain score (KSPS), Hospital for Special Surgery score (HSS), kinematic characteristics including postoperative component alignment, tibial posterior slope and joint line, and complication rate. However, PS TKA is superior to CR TKA regarding post-operative knee range of motion (ROM) [Random Effect model (RE), Mean Difference (MD) = -7.07, 95% Confidential Interval (CI) -10.50 to -3.65, p<0.0001], improvement of ROM (Fixed Effect model (FE), MD = -5.66, 95% CI -10.79 to -0.53, p = 0.03) and femoral-tibial angle [FE, MD = 0.85, 95% CI 0.46 to 1.25, p<0.0001]. There are no clinically relevant differences between CR and PS TKA in terms of clinical, functional, radiological outcome, and complications, while PS TKA is superior to CR TKA in respects of ROM, while whether this superiority matters or not in clinical practice still needs further investigation and longer follow-up.
Classification and Surgical Repair of Ramp Lesions of the Medial Meniscus.
Thaunat, Mathieu; Fayard, Jean Marie; Guimaraes, Tales M; Jan, Nicolas; Murphy, Colin G; Sonnery-Cottet, Bertrand
2016-08-01
Ramp lesions of the medial meniscus are commonly associated with anterior cruciate ligament ruptures and consist of longitudinal peripheral tears of the posterior horn of the medial meniscus. Given the frequency of partial-thickness tears, they can be difficult to diagnose arthroscopically from the anterior compartment. We describe a classification of the different types of ramp lesions depending on both tear pattern (partial- or full-thickness tear) and associated meniscotibial ligament disruption. An original technique of arthroscopic suture placement through a single posteromedial portal with a 25° curved suture hook device is described.
The use of implants as retainers for removable partial dentures.
Zinner, Ira D; Markovits, Stanley; Jansen, Curtis E; Reid, Patrick E; Shapiro, Herbert J
2010-01-01
There has been little presented in the literature regarding the use of implant bodies as retainers for removable partial dentures. However, these fixtures can be a useful asset for restorative dentists, as they can be used when there is insufficient bone for a fixed prosthesis or as retainers for a provisional appliance until additional dental treatment is possible.
Nationwide survey of partial fundoplication in Korea: comparison with total fundoplication.
Lee, Chang Min; Park, Joong-Min; Lee, Han Hong; Jun, Kyong Hwa; Kim, Sungsoo; Seo, Kyung Won; Park, Sungsoo; Kim, Jong-Han; Kim, Jin-Jo; Han, Sang-Uk
2018-06-01
Laparoscopic total fundoplication is the standard surgery for gastroesophageal reflux disease. However, partial fundoplication may be a viable alternative. Here, we conducted a nationwide survey of partial fundoplication in Korea. The Korean Anti-Reflux Surgery study group recorded 32 cases of partial fundoplication at eight hospitals between September 2009 and January 2016. The surgical outcomes and postoperative adverse symptoms in these cases were evaluated and compared with 86 cases of total fundoplication. Anterior partial fundoplication was performed in 20 cases (62.5%) and posterior in 12 (37.5%). In most cases, partial fundoplication was a secondary procedure after operations for other conditions. Half of patients who underwent partial fundoplication had typical symptoms at the time of initial diagnosis, and most of them showed excellent (68.8%), good (25.0%), or fair (6.3%) symptom resolution at discharge. Compared to total fundoplication, partial fundoplication showed no difference in the resolution rate of typical and atypical symptoms. However, adverse symptoms such as dysphagia, difficult belching, gas bloating and flatulence were less common after partial fundoplication. Although antireflux surgery is not popular in Korea and total fundoplication is the primary surgical choice for gastroesophageal reflux disease, partial fundoplication may be useful in certain conditions because it has less postoperative adverse symptoms but similar efficacy to total fundoplication.
Maxillary overlay removable partial dentures for the restoration of worn teeth.
Fonseca, Júlio; Nicolau, Pedro; Daher, Tony
2011-04-01
Prolonged tooth maintenance by a more aged population considerably increases the probability of dentists having to treat patients with high levels of tooth wear. Pathological tooth wear, caused primarily by parafunction, seems to be a growing problem that affects a large number of adult patients. The clinical report presents a case of a partially edentulous patient with an elevated degree of wear in the upper jaw caused by attrition and erosion, rehabilitated with a maxillary overlay removable partial denture (ORPD) consisting of a chrome-cobalt (Cr-Co) framework with anterior acrylic resin veneers, posterior cast overlays, and acrylic resin denture bases. Removable partial prosthesis is a treatment alternative when teeth are found to be severely worn or when the patient needs a simple and economical option. Because economics is a conditional factor of the treatment, the clinician should present different treatment alternatives to the patient, in which the overlay prosthesis can be considered.
Schwarzkopf, Ran; Laster, Scott K; Cross, Michael B; Lenz, Nathaniel M
2016-04-01
Proper ligament tension in flexion with posterior cruciate retaining (CR) total knee arthroplasty (TKA) has long been associated with clinical success. The purpose of this study was to determine the effect of varying levels of posterior cruciate ligament (PCL) release on the tibiofemoral kinematics and PCL strain. A computational analysis was performed and varying levels of PCL release were simulated. Tibiofemoral kinematics was evaluated. The maximum PCL strain was determined for each bundle to evaluate the risk of rupture based on the failure strain. The femoral AP position shifted anteriorly as the PCL stiffness was reduced. PCL strain in both bundles increased as stiffness was reduced. The model predicts that the AL bundle should not rupture for a 75% release. Risk of PM bundle rupture is greater than AL bundle. Our findings suggest that a partial PCL release impacts tibiofemoral kinematics and ligament tension and strain. The relationship is dynamic and care should be taken when seeking optimal balance intra-operatively.
Haldipur, Parthiv; Dang, Derek; Aldinger, Kimberly A; Janson, Olivia K; Guimiot, Fabien; Adle-Biasette, Homa; Dobyns, William B; Siebert, Joseph R; Russo, Rosa; Millen, Kathleen J
2017-01-16
FOXC1 loss contributes to Dandy-Walker malformation (DWM), a common human cerebellar malformation. Previously, we found that complete Foxc1 loss leads to aberrations in proliferation, neuronal differentiation and migration in the embryonic mouse cerebellum (Haldipur et al., 2014). We now demonstrate that hypomorphic Foxc1 mutant mice have granule and Purkinje cell abnormalities causing subsequent disruptions in postnatal cerebellar foliation and lamination. Particularly striking is the presence of a partially formed posterior lobule which echoes the posterior vermis DW 'tail sign' observed in human imaging studies. Lineage tracing experiments in Foxc1 mutant mouse cerebella indicate that aberrant migration of granule cell progenitors destined to form the posterior-most lobule causes this unique phenotype. Analyses of rare human del chr 6p25 fetal cerebella demonstrate extensive phenotypic overlap with our Foxc1 mutant mouse models, validating our DWM models and demonstrating that many key mechanisms controlling cerebellar development are likely conserved between mouse and human.
Graves, William W.; Binder, Jeffrey R.; Desai, Rutvik H.; Humphries, Colin; Stengel, Benjamin C.; Seidenberg, Mark S.
2014-01-01
Are there multiple ways to be a skilled reader? To address this longstanding, unresolved question, we hypothesized that individual variability in using semantic information in reading aloud would be associated with neuroanatomical variation in pathways linking semantics and phonology. Left-hemisphere regions of interest for diffusion tensor imaging analysis were defined based on fMRI results, including two regions linked with semantic processing – angular gyrus (AG) and inferior temporal sulcus (ITS) – and two linked with phonological processing – posterior superior temporal gyrus (pSTG) and posterior middle temporal gyrus (pMTG). Effects of imageability (a semantic measure) on response times varied widely among individuals and covaried with the volume of pathways through the ITS and pMTG, and through AG and pSTG, partially overlapping the inferior longitudinal fasciculus and the posterior branch of the arcuate fasciculus. These results suggest strategy differences among skilled readers associated with structural variation in the neural reading network. PMID:24735993
Spatially explicit models for inference about density in unmarked or partially marked populations
Chandler, Richard B.; Royle, J. Andrew
2013-01-01
Recently developed spatial capture–recapture (SCR) models represent a major advance over traditional capture–recapture (CR) models because they yield explicit estimates of animal density instead of population size within an unknown area. Furthermore, unlike nonspatial CR methods, SCR models account for heterogeneity in capture probability arising from the juxtaposition of animal activity centers and sample locations. Although the utility of SCR methods is gaining recognition, the requirement that all individuals can be uniquely identified excludes their use in many contexts. In this paper, we develop models for situations in which individual recognition is not possible, thereby allowing SCR concepts to be applied in studies of unmarked or partially marked populations. The data required for our model are spatially referenced counts made on one or more sample occasions at a collection of closely spaced sample units such that individuals can be encountered at multiple locations. Our approach includes a spatial point process for the animal activity centers and uses the spatial correlation in counts as information about the number and location of the activity centers. Camera-traps, hair snares, track plates, sound recordings, and even point counts can yield spatially correlated count data, and thus our model is widely applicable. A simulation study demonstrated that while the posterior mean exhibits frequentist bias on the order of 5–10% in small samples, the posterior mode is an accurate point estimator as long as adequate spatial correlation is present. Marking a subset of the population substantially increases posterior precision and is recommended whenever possible. We applied our model to avian point count data collected on an unmarked population of the northern parula (Parula americana) and obtained a density estimate (posterior mode) of 0.38 (95% CI: 0.19–1.64) birds/ha. Our paper challenges sampling and analytical conventions in ecology by demonstrating that neither spatial independence nor individual recognition is needed to estimate population density—rather, spatial dependence can be informative about individual distribution and density.
Posterior fossa meningiomas: surgical experience in 161 cases.
Roberti, F; Sekhar, L N; Kalavakonda, C; Wright, D C
2001-07-01
We report the clinical, radiological, and surgical findings of patients with posterior fossa meningiomas surgically treated at our institution over the last 6 years. We reviewed 161 consecutive cases of posterior fossa meningiomas operated on between April 1993 and April 1999 at The George Washington University Medical Center. There were 128 female and 33 male patients (mean age 47 years, range of 10-81 years). Meningiomas were classified as petroclival (110 cases), foramen magnum (21 cases), cerebellar hemispheric, lateral tentorial (14 cases), cerebellopontine angle (9 cases), and jugular foramen (7 cases). Mean tumor equivalent diameter (TED) = (D1xD2xDE)(1/3) was 3.1 cm (range of 0.53-8.95). Head pain (50% of cases) and disturbance of gait (44%) were the most common presenting symptoms, and cranial neuropathies the most common neurological signs on admission. Mean preoperative performance status (Karnofsky scale) was 80.2 (range 40-100). Surgical approaches to these tumors included partial labyrinthectomy petrous apicectomy, fronto-temporal/fronto-temporal orbitozygomatic osteotomy, retrosigmoidal, extreme lateral, transpetrosal, and combined. In 38 cases a staged procedure was performed. Gross-total resection was achieved in 57% of patients, and subtotal/partial in 43%. Surgical mortality was 2.5% and complications were encountered in 41% of patients. Postoperative CSF leak occurred in 22 cases (13.6%). The mean follow-up was 19 months, ranging from 0.2 to 63.6, and the mean performance status of patients with a follow-up of at least 12 months was 77 (range of 40-100). Recurrence or progression of disease was found in 13.7% of cases (follow-up 2 years or more). Our experience suggests that although posterior fossa meningiomas represent a continuing challenge for contemporary neurosurgeons, such tumors may be completely or subtotally removed with low rate of mortality and acceptable morbidity, allowing most of these patients to achieve a good outcome in a long-term follow-up.
Tilea, B; Delezoide, A L; Khung-Savatovski, S; Guimiot, F; Vuillard, E; Oury, J F; Garel, C
2007-06-01
To compare magnetic resonance imaging (MRI) and fetopathological findings in the evaluation of non-cystic fetal posterior fossa anomalies and to describe associated abnormalities. This was a prospective study from 2000 to 2005 of fetuses identified on ultrasound as having sonographic suspicion of posterior fossa malformation. All underwent a thorough MRI examination of the fetal brain, after which we classified each fetus as presenting one of the following pathologies: vermian hypoplasia or agenesis, cerebellar and/or brain stem hypoplasia, destructive or dysplastic lesions. All of the pregnancies were then terminated, after which the whole fetus underwent fetopathological examination. We compared the findings from MRI and fetopathological examinations and recorded the associated cerebral and extracerebral abnormalities. Twenty-five fetuses were included. MRI was performed at a mean gestational age of 31 weeks, and fetopathological examination at 33 weeks. In 12 cases we observed vermian hypoplasia, six had partial vermian agenesis, 11 had cerebellar hemisphere hypoplasia, seven had brain stem hypoplasia, four had destructive lesions and six had dysplastic lesions. The two techniques were similar in their performance with respect to the detection of vermian agenesis, brain stem hypoplasia and destructive lesions. There were four false-positive results of MRI for vermian hypoplasia and a poor agreement regarding cerebellar hemisphere hypoplasia. No dysplastic lesions were diagnosed by MRI. None of the posterior fossa malformations was isolated and many cerebral and extracerebral abnormalities were found. A systematic analysis of the posterior fossa in fetal MRI makes it possible to diagnose accurately most posterior fossa malformations. These malformations never occurred in isolation in our study.
Gingival Retraction Methods for Fabrication of Fixed Partial Denture: Literature Review
S, Safari; Ma, Vossoghi Sheshkalani; Mi, Vossoghi Sheshkalani; F, Hoseini Ghavam; M, Hamedi
2016-01-01
Fixed dental prosthesis success requires appropriate impression taking of the prepared finish line. This is critical in either tooth supported fixed prosthesis (crown and bridge) or implant supported fixed prosthesis (solid abutment). If the prepared finish line is adjacent to the gingival sulcus, gingival retraction techniques should be used to decrease the marginal discrepancy among the restoration and the prepared abutment. Accurate marginal positioning of the restoration in the prepared finish line of the abutment is required for therapeutic, preventive and aesthetic purposes. In this article, conventional and modern methods of gingival retraction in the fixed tooth supported prosthesis and fixed implant supported prosthesis are expressed. PubMed and Google Scholar databases were searched manually for studies on gingival tissue managements prior to impression making in fixed dental prosthesis since 1975. Conclusions were extracted and summarized. Keywords were impression making, gingival retraction, cordless retraction, and implant. Gingival retraction techniques can be classified as mechanical, chemical or surgical. In this article, different gingival management techniques are discussed. PMID:28959744
Gingival Retraction Methods for Fabrication of Fixed Partial Denture: Literature Review.
S, Safari; Ma, Vossoghi Sheshkalani; Mi, Vossoghi Sheshkalani; F, Hoseini Ghavam; M, Hamedi
2016-06-01
Fixed dental prosthesis success requires appropriate impression taking of the prepared finish line. This is critical in either tooth supported fixed prosthesis (crown and bridge) or implant supported fixed prosthesis (solid abutment). If the prepared finish line is adjacent to the gingival sulcus, gingival retraction techniques should be used to decrease the marginal discrepancy among the restoration and the prepared abutment. Accurate marginal positioning of the restoration in the prepared finish line of the abutment is required for therapeutic, preventive and aesthetic purposes. In this article, conventional and modern methods of gingival retraction in the fixed tooth supported prosthesis and fixed implant supported prosthesis are expressed. PubMed and Google Scholar databases were searched manually for studies on gingival tissue managements prior to impression making in fixed dental prosthesis since 1975. Conclusions were extracted and summarized. Keywords were impression making, gingival retraction, cordless retraction, and implant. Gingival retraction techniques can be classified as mechanical, chemical or surgical. In this article, different gingival management techniques are discussed.
Park, Young-Jin; Cho, Sung-Am
2010-06-01
To evaluate the survival rate of implants placed in the maxillary tuberosity region using the fixed prosthesis in partially edentulous cases. Of implant-treated patients who visited Kyung Pook National University Hospital, 7 partially edentulous patients (2 male and 5 female; mean age, 52.3 years; range, approximately 43 to 65) were selected according to the following criteria: 1) less than 3-mm thickness alveolar bone reaming at the first molar area and 2) 1 to 2 fixture premolars, with the additional implant at the maxillary tuberosity region. For the control group, patients who had nontuberosity areas were selected. After 1 to 7 years, marginal bone level, fixture mobility, and radiolucency of tuberosity fixtures of the fixed prostheses were evaluated by digital panorama (Starpacs, Infinitt, Seoul, Korea). None of the fixtures of the tuberosity-installed implants for 1 to 7 years failed. The marginal bone level around the implants of the maxillary tuberosity 1 to 6 years (average 3.4 years) after the final prostheses was approximately 0.6 to 1.3 mm, with an average of 0.94 mm. The fixture installation at the maxillary tuberosity using the unilateral partially edentulous implant-fixed prosthesis would be a clinically acceptable treatment module. 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Materials for interocclusal records and their ability to reproduce a 3-dimensional jaw relationship.
Ockert-Eriksson, G; Eriksson, A; Lockowandt, P; Eriksson, O
2000-01-01
The purpose of this study was to determine if accuracy and dimensional stability of vinyl polysiloxanes and irreversible hydrocolloids stabilized by a tray used for fixed prosthodontics, removable partial, and complete denture cases are comparable to those of waxes and record rims and if storage time (24 hours or 6 days) affects dimensional stability of the tested materials. Two waxes, two record rims, three vinyl polysiloxanes, and one irreversible hydrocolloid (alginate) were examined. Three pairs of master casts with measuring steel rods were mounted on an articulator (initial position). Five records were made of each material, and the upper cast was remounted after 24 hours or 6 days so that deviations from the initial position could be measured. Vinyl polysiloxanes reinforced by a stabilization tray were the most accurate materials able to reproduce a settled interocclusal position. Mounting casts (fixed prosthodontics cases) without records gave accuracy similar to wax records. Record rims used for removable partial and complete denture cases produced lesser accuracy than vinyl polysiloxanes and irreversible hydrocolloid stabilized by a tray. Accuracy was not significantly affected by storage time. The results show that accuracy of vinyl polysiloxanes and irreversible hydrocolloids reinforced by a tray is superior to that of record rims with regard to the complete denture case and is among the most accurate with regard to the removable partial denture case. For fixed prosthodontics, however, reinforcement is unnecessary.
Bodin, Frédéric; Dissaux, Caroline; Dupret-Bories, Agnes; Schohn, Thomas; Fiquet, Caroline; Bruant-Rodier, Catherine
2016-01-01
The transverse musculocutaneous gracilis (TMG) flap has become a common solution for breast reconstruction. However, the safe skin paddle limits are not yet understood. In this study, we attempted to address this issue based on our experiences with inferior and posterior skin paddle extension. Forty-four breast reconstructions with TMG flaps performed between November 2010 and January 2014 were analyzed retrospectively. For the first 20 cases, the flap skin paddle was extended 3 cm posteriorly to the middle thigh (group 1). For the next 20 flaps (group 2), the posterior tip was limited to this line, whereas more fat was recruited inferiorly. In the four cases of group 3, the skin flap was extended posteriorly with a second vascular pedicle from the profunda artery perforator (PAP) flap. The weights and the dimensions of the flaps, operating durations, and postoperative complications of the entire series were analyzed. Groups 1 and 2 were statistically compared. Flap complications were statistically more frequent in group 1 compared with group 2 (45 vs. 0%, P = 0.0012); 40% posterior flap tip necrosis was observed in group 1. Conversely, donor site complications were statistically more frequent in group 2 than in group 1 (40 vs. 5%, P = 0.019) with 35% inner thigh dehiscence. In the TMG with extended PAP flap group, the operating duration was 77 min longer compared with the rest of the series with no donor site complications. In one case, limited necrosis occurred at the anterior skin tip. Harvesting the posterior portion of the TMG up to the middle of the posterior thigh may lead to partial flap necrosis. Extending subcutaneous fat removal under the inferior skin incision may increase the risk of donor site complications. Adding a second vascular pedicle from the PAP flap may improve posterior TMG tip perfusion at the expense of a longer operation. © 2015 Wiley Periodicals, Inc.
Fixed Point Results for G-α-Contractive Maps with Application to Boundary Value Problems
Roshan, Jamal Rezaei
2014-01-01
We unify the concepts of G-metric, metric-like, and b-metric to define new notion of generalized b-metric-like space and discuss its topological and structural properties. In addition, certain fixed point theorems for two classes of G-α-admissible contractive mappings in such spaces are obtained and some new fixed point results are derived in corresponding partially ordered space. Moreover, some examples and an application to the existence of a solution for the first-order periodic boundary value problem are provided here to illustrate the usability of the obtained results. PMID:24895655
Schönberger, Joana; Erdelt, Kurt-Jürgen; Bäumer, Daniel; Beuer, Florian
2017-11-01
The purpose of this in vitro study was to compare the precision of fit of frameworks milled from semi-sintered regular zirconia and high-translucent (HT) zirconia blanks, fabricated with two different CAD/CAM systems. Three-unit, posterior fixed dental prostheses (FDP) frameworks were fabricated for standardized dies (n = 11) with two different laboratory computer-aided design (CAD)/computer-aided manufacturing (CAM) systems (Cercon/Ceramill). The replica technique was used to evaluate the marginal and internal fit under an optical microscope. Evaluation of the data was performed according to prior studies at a level of significance of 5%. The systems showed a statistically significant influence on the internal fit of the frameworks (p ≤ 0.001) and on the marginal fit (p < 0.001). The type of material showed no influence on the marginal fit for the Cercon system (p = 0.636) and on the marginal fit (p = 0.064) and the internal fit (p = 0.316) for the Ceramill system, while regular zirconia from Cercon showed higher internal values than HT zirconia (p = 0.016). Both investigated systems showed clinically acceptable values within the limitations of this in vitro study. However, one showed less internal accuracy when regular zirconia was used.
Miao, De-chao; Zhang, Bao-yang; Lei, Tao; Shen, Yong
2017-01-01
Background The aim of this study was to analyze the clinical features and to evaluate the efficacy of anterior partial corpectomy and titanium mesh fusion and internal fixation of old fracture dislocation of the lower cervical spine. Material/Methods We retrospectively analyzed the clinical data of 52 patients with old lower cervical fracture and dislocation treated with anterior partial corpectomy and titanium mesh fusion fixation between January 2008 and December 2013, with a mean follow-up period of 4.1 years. There were 35 males and 17 females. Patient radiological data and clinical parameters were recorded and compared before and after the operations. Results The average follow-up was 4.1 years. Intervertebral height and physiological curvature were well-reconstructed for all cases. No loosening or rupturing of titanium plate or screw occurred. The neurological function of the patients with incomplete spinal cord injury was significantly improved, and the function of the nerve roots at the injury level was also improved in patients with complete spinal cord injury. Bone fusion was completed within 6 months to 1 year after surgery. Conclusions Completed decompression, sequence and physiological curvature of the cervical vertebra, immediate and long-term anterior cervical column support, and nerve function restoration can be achieved by using anterior partial corpectomy and titanium mesh fusion and internal fixation to treat old fracture dislocation of the lower cervical spine. For cases with locked facet joints or posterior structures invading the vertebral canal, the combined anterior and posterior approaches should be performed, when necessary, to achieve better results. PMID:29184051
Realistic respiratory motion margins for external beam partial breast irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conroy, Leigh; Quirk, Sarah; Department of Physics and Astronomy, University of Calgary, Calgary, Alberta T2N 1N4
Purpose: Respiratory margins for partial breast irradiation (PBI) have been largely based on geometric observations, which may overestimate the margin required for dosimetric coverage. In this study, dosimetric population-based respiratory margins and margin formulas for external beam partial breast irradiation are determined. Methods: Volunteer respiratory data and anterior–posterior (AP) dose profiles from clinical treatment plans of 28 3D conformal radiotherapy (3DCRT) PBI patient plans were used to determine population-based respiratory margins. The peak-to-peak amplitudes (A) of realistic respiratory motion data from healthy volunteers were scaled from A = 1 to 10 mm to create respiratory motion probability density functions. Dosemore » profiles were convolved with the respiratory probability density functions to produce blurred dose profiles accounting for respiratory motion. The required margins were found by measuring the distance between the simulated treatment and original dose profiles at the 95% isodose level. Results: The symmetric dosimetric respiratory margins to cover 90%, 95%, and 100% of the simulated treatment population were 1.5, 2, and 4 mm, respectively. With patient set up at end exhale, the required margins were larger in the anterior direction than the posterior. For respiratory amplitudes less than 5 mm, the population-based margins can be expressed as a fraction of the extent of respiratory motion. The derived formulas in the anterior/posterior directions for 90%, 95%, and 100% simulated population coverage were 0.45A/0.25A, 0.50A/0.30A, and 0.70A/0.40A. The differences in formulas for different population coverage criteria demonstrate that respiratory trace shape and baseline drift characteristics affect individual respiratory margins even for the same average peak-to-peak amplitude. Conclusions: A methodology for determining population-based respiratory margins using real respiratory motion patterns and dose profiles in the AP direction was described. It was found that the currently used respiratory margin of 5 mm in partial breast irradiation may be overly conservative for many 3DCRT PBI patients. Amplitude alone was found to be insufficient to determine patient-specific margins: individual respiratory trace shape and baseline drift both contributed to the dosimetric target coverage. With respiratory coaching, individualized respiratory margins smaller than the full extent of motion could reduce planning target volumes while ensuring adequate coverage under respiratory motion.« less
Topological design of all-ceramic dental bridges for enhancing fracture resistance.
Zhang, Zhongpu; Chen, Junning; Li, Eric; Li, Wei; Swain, Michael; Li, Qing
2016-06-01
Layered all-ceramic systems have been increasingly adopted in major dental prostheses. However, ceramics are inherently brittle, and they often subject to premature failure under high occlusion forces especially in the posterior region. This study aimed to develop mechanically sound novel topological designs for all-ceramic dental bridges by minimizing the fracture incidence under given loading conditions. A bi-directional evolutionary structural optimization (BESO) technique is implemented within the extended finite element method (XFEM) framework. Extended finite element method allows modeling crack initiation and propagation inside all-ceramic restoration systems. Following this, BESO searches the optimum distribution of two different ceramic materials, namely porcelain and zirconia, for minimizing fracture incidence. A performance index, as per a ratio of peak tensile stress to material strength, is used as a design objective. In this study, the novel XFEM based BESO topology optimization significantly improved structural strength by minimizing performance index for suppressing fracture incidence in the structures. As expected, the fracture resistance and factor of safety of fixed partial dentures structure increased upon redistributing zirconia and porcelain in the optimal topological configuration. Dental CAD/CAM systems and the emerging 3D printing technology were commercially available to facilitate implementation of such a computational design, exhibiting considerable potential for clinical application in the future. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
A fully Sinc-Galerkin method for Euler-Bernoulli beam models
NASA Technical Reports Server (NTRS)
Smith, R. C.; Bowers, K. L.; Lund, J.
1990-01-01
A fully Sinc-Galerkin method in both space and time is presented for fourth-order time-dependent partial differential equations with fixed and cantilever boundary conditions. The Sinc discretizations for the second-order temporal problem and the fourth-order spatial problems are presented. Alternate formulations for variable parameter fourth-order problems are given which prove to be especially useful when applying the forward techniques to parameter recovery problems. The discrete system which corresponds to the time-dependent partial differential equations of interest are then formulated. Computational issues are discussed and a robust and efficient algorithm for solving the resulting matrix system is outlined. Numerical results which highlight the method are given for problems with both analytic and singular solutions as well as fixed and cantilever boundary conditions.
Sukotjo, Cortino
2013-01-01
Implant treatment has become the treatment of choice to replace missing teeth in partially edentulous areas. Dental implants present different biological and biomechanical characteristics than natural teeth. Occlusion is considered to be one of the most important factors contributing to implant success. Most literature on implant occlusal concepts is based on expert opinion, anecdotal experiences, in vitro and animal studies, and only limited clinical research. Furthermore, scientific literature regarding implant occlusion, particularly in implant-supported fixed dental prostheses remains controversial. In this study, the current status of implant occlusion was reviewed and discussed. Further randomized clinical research to investigate the correlation between implant occlusion, the implant success rate, and its risk factors is warranted to determine best clinical practices. PMID:23678387
Meniscal healing after meniscal repair: a CT arthrography assessment.
Pujol, Nicolas; Panarella, Ludovico; Selmi, Tarik Ait Si; Neyret, Philippe; Fithian, Donald; Beaufils, Philippe
2008-08-01
Studies evaluating healing of repaired meniscus are rare and primarily retrospective. The aim of this study was to assess whether there were different healing rates for arthroscopic meniscal repair with respect to the different zones of the meniscus. This study was conducted to assess outcomes and to document anatomic characteristics of the repaired meniscus with postoperative arthrography combined with computed tomography (arthro-CT), particularly the dimensions and healing of the repaired meniscus. Case series; Level of evidence, 4. Fifty-three arthroscopic meniscal repairs were prospectively evaluated between 2002 and 2004 in 2 orthopaedic departments. There were 36 medial and 17 lateral torn menisci. All ACL tears (n = 31, 58.5%) underwent reconstruction. Patients were preoperatively evaluated by magnetic resonance imaging. Clinical evaluation included International Knee Documentation Committee (IKDC) scores before the operation and 6 and 12 months afterward. Healing criteria were evaluated at 6 months by arthro-CT scan. Three parameters were evaluated--healing in thickness (Henning criteria), overall healing rate, and reduction in the width of the remaining meniscus. According to the objective IKDC score, 26 patients were graded A, 20 B, and 4 C (92% good results). The mean subjective IKDC score was 78.9 (standard deviation [SD], 16.2). According to Henning's criteria, 58% of the menisci healed completely, 24% partially, and 18% failed. The overall healing rate was 73.1% (SD, 38.5). Twenty tears located in the posterior part had a healing rate of 59.8% (SD, 46.0). Nineteen tears extending from the posterior to the middle part had a healing rate of 79.2% (SD, 28.2). Isolated tears located in the posterior part had a lower healing rate (P < .05). There was a 9% +/- 1.2% reduction in the width of the remaining medial meniscus in the middle and posterior repaired portions (P < .02). There was a 15% +/- 14% reduction in the width of the remaining lateral meniscus in the middle repaired portion (P < .01). Complete healing of the posterior segment was associated with reduction in the width of the meniscus (P < .04). A modern technique using all-inside fixation or outside-in sutures provided good clinical and anatomic outcomes. No statistically significant effect on ACL reconstruction or laterality (medial vs lateral) on overall healing after meniscal repair was identified. Partial healing occurred often, with a stable tear on a narrowed and painless meniscus. The posterior segment healing rate remained low, suggesting a need for further technical improvements.
Akhtar, Saeed; Alkhalaf, Mousa; Khan, Adnan A; Almubrad, Turki M
2016-08-01
We report ultrastructural features and transmission electron tomography of the dhub lizard (Uromastyx aegyptia) cornea and its adaptation to hot and dry environments. Six corneas of dhub lizards were fixed in 2.5% glutaraldehyde and processed for electron microscopy and tomography. The ultrathin sections were observed with a JEOL 1400 transmission electron microscope. The cornea of the dhub lizard is very thin (~28-30 µm). The epithelium constitutes ~14% of the cornea, whereas the stroma constitutes 80% of the cornea. The middle stromal lamellae are significantly thicker than anterior and posterior stromal lamellae. Collagen fibril (CF) diameters in the anterior stroma are variable in size (25-75 nm). Proteoglycans (PGs) are very large in the middle and posterior stroma, whereas they are small in the anterior stroma. Three-dimensional electron tomography was carried out to understand the structure and arrangement of the PG and CFs. The presence of large PGs in the posterior and middle stroma might help the animal retain a large amount of water to protect it from dryness. The dhub corneal structure is equipped to adapt to the dry and hot desert environment.
[Laparoscopic promontofixation technique].
Mugnier, C; Gaston, R; Hoepffner, J L; Piéchaud, T
2005-11-01
Laparoscopic promontofixation often remains possible whatever the previous history of pelvic surgery, including the placing of prosthetic material. Preoperative care is standardized and is accompanied by antibiotic prophylaxis, preventive antithrombotic treatment and in the event of a history of pelvic surgery, a digestive preparation. Positioning of the patient must plan a 30 degrees Trendelenbourg position. After the introduction of trocars, initial surgery comprises interrectovaginal dissection to free the whole posterior surface of the vagina. This is followed by the installation of a posterior mesh pre-cut in an arch. The anterior face of the promontory is then freed after incision of the posterior peritoneum with the patient placed beforehand in a Trendelenbourg position. After intervesical vaginal dissection, the anterior prosthesis comprising a precut polyester mesh is fixed avoiding excess traction. The end of the surgery involves careful reperitonization of all the prosthetic parts. Possible specific surgical complications are vascular and visceral wounds. Postoperative secondary haemorrhage and gastrointestinal occlusion may occur. Occurrence of an inflammatory syndrome and low back pain suggests spondylodicitis and MRI should be performed. Vaginal erosion on the prosthesis (1.6 to 10% depending on the series) may occur after several months and seems relatively independent of the prosthetic material used.
NASA Astrophysics Data System (ADS)
Mazurek, Przemysław
2013-09-01
Matchmoving (Match Moving) is the process used for the estimation of camera movements for further integration of acquired video image with computer graphics. The estimation of movements is possible using pattern recognition, 2D and 3D tracking algorithms. The main problem for the workflow is the partial occlusion of markers by the actor, because manual rotoscoping is necessary for fixing of the chroma-keyed footage. In the paper, the partial occlusion problem is solved using the invented, selectively active electronic markers. The sensor network with multiple infrared links detects occlusion state (no-occlusion, partial, full) and switch LED's based markers.
Munot, Vimal Kantilal; Nayakar, Ramesh P; Patil, Raghunath
2017-01-01
The restoration of normal function and esthetic appearance with a dental prosthesis is a major challenge in the rehabilitation of patients who have lost their teeth and surrounding bone because of surgery for oral cyst or tumor. Rehabilitation with fixed or removable prosthesis is even more challenging when the edentulous span is long and the ridge is defective. Anatomic deformities and unfavorable biomechanics encountered in the region of resection add to the misery. In such situation, a fixed-removable prosthesis allows favorable biomechanical stress distribution along with restoration of esthetics, phonetics, comfort, hygiene, and better postoperative care and maintenance. This article describes rehabilitation of two cases with mandibular defects with an attachment-retained fixed-removable hybrid prosthesis.
Mihata, Teruhisa; Bui, Christopher N H; Akeda, Masaki; Cavagnaro, Matthew A; Kuenzler, Michael; Peterson, Alexander B; McGarry, Michelle H; Itami, Yasuo; Limpisvasti, Orr; Neo, Masashi; Lee, Thay Q
2017-12-01
Biomechanical and clinical success of the superior capsule reconstruction (SCR) using fascia lata (FL) grafts has been reported. In the United States, human dermal (HD) allograft has been used successfully for SCRs; however, the biomechanical characteristics have not been reported. Eight cadaveric shoulders were tested in 5 conditions: (1) intact; (2) irreparable supraspinatus tear; (3) SCR using FL allograft with anterior and posterior suturing; (4) SCR using HD allograft with anterior and posterior suturing; and (5) SCR using HD allograft with posterior suturing. Rotational range of motion, superior translation, glenohumeral joint force, and subacromial contact were measured at 0°, 30°, and 60° of glenohumeral abduction in the scapular plane. Graft dimensions before and after testing were also recorded. Biomechanical parameters were compared using a repeated-measures analysis of variance with Tukey post hoc test, and graft dimensions were compared using a Student t-test (P < .05). Irreparable supraspinatus tear significantly increased superior translation, superior glenohumeral joint force, and subacromial contact pressure, which were completely restored with the SCR FL allografts. Both SCR HD allograft repairs partially restored superior translation and completely restored subacromial contact and superior glenohumeral joint force. The HD allografts significantly elongated by 15% during testing, whereas the FL allograft lengths were unchanged. Single-layered HD SCR allografts partially restored superior glenohumeral stability, whereas FL allograft SCR completely restored the superior glenohumeral stability. This may be due to the greater flexibility of the HD allograft, and the SCR procedure used was developed on the basis of FL grafts. Published by Elsevier Inc.
Computational Model for Oxygen Transport and Consumption in Human Vitreous
Filas, Benjamen A.; Shui, Ying-Bo; Beebe, David C.
2013-01-01
Purpose. Previous studies that measured liquefaction and oxygen content in human vitreous suggested that exposure of the lens to excess oxygen causes nuclear cataracts. Here, we developed a computational model that reproduced available experimental oxygen distributions for intact and degraded human vitreous in physiologic and environmentally perturbed conditions. After validation, the model was used to estimate how age-related changes in vitreous physiology and structure alter oxygen levels at the lens. Methods. A finite-element model for oxygen transport and consumption in the human vitreous was created. Major inputs included ascorbate-mediated oxygen consumption in the vitreous, consumption at the posterior lens surface, and inflow from the retinal vasculature. Concentration-dependent relations were determined from experimental human data or estimated from animal studies, with the impact of all assumptions explored via parameter studies. Results. The model reproduced experimental data in humans, including oxygen partial pressure (Po2) gradients (≈15 mm Hg) across the anterior-posterior extent of the vitreous body, higher oxygen levels at the pars plana relative to the vitreous core, increases in Po2 near the lens after cataract surgery, and equilibration in the vitreous chamber following vitrectomy. Loss of the antioxidative capacity of ascorbate increases oxygen levels 3-fold at the lens surface. Homogeneous vitreous degeneration (liquefaction), but not partial posterior vitreous detachment, greatly increases oxygen exposure to the lens. Conclusions. Ascorbate content and the structure of the vitreous gel are critical determinants of lens oxygen exposure. Minimally invasive surgery and restoration of vitreous structure warrant further attention as strategies for preventing nuclear cataracts. PMID:24008409
Shindigs, brunches, and rodeos: the neural basis of event words.
Bedny, Marina; Dravida, Swethasri; Saxe, Rebecca
2014-09-01
Events (e.g., "running" or "eating") constitute a basic type within human cognition and human language. We asked whether thinking about events, as compared to other conceptual categories, depends on partially independent neural circuits. Indirect evidence for this hypothesis comes from previous studies showing elevated posterior temporal responses to verbs, which typically label events. Neural responses to verbs could, however, be driven either by their grammatical or by their semantic properties. In the present experiment, we separated the effects of grammatical class (verb vs. noun) and semantic category (event vs. object) by measuring neural responses to event nouns (e.g., "the hurricane"). Participants rated the semantic relatedness of event nouns, as well as of two categories of object nouns-animals (e.g., "the alligator") and plants (e.g., "the acorn")-and three categories of verbs-manner of motion (e.g., "to roll"), emission (e.g., "to sparkle"), and perception (e.g., "to gaze"). As has previously been observed, we found larger responses to verbs than to object nouns in the left posterior middle (LMTG) and superior (LSTG) temporal gyri. Crucially, we also found that the LMTG responds more to event than to object nouns. These data suggest that part of the posterior lateral temporal response to verbs is driven by their semantic properties. By contrast, a more superior region, at the junction of the temporal and parietal cortices, responded more to verbs than to all nouns, irrespective of their semantic category. We concluded that the neural mechanisms engaged when thinking about event and object categories are partially dissociable.
Computational model for oxygen transport and consumption in human vitreous.
Filas, Benjamen A; Shui, Ying-Bo; Beebe, David C
2013-10-15
Previous studies that measured liquefaction and oxygen content in human vitreous suggested that exposure of the lens to excess oxygen causes nuclear cataracts. Here, we developed a computational model that reproduced available experimental oxygen distributions for intact and degraded human vitreous in physiologic and environmentally perturbed conditions. After validation, the model was used to estimate how age-related changes in vitreous physiology and structure alter oxygen levels at the lens. A finite-element model for oxygen transport and consumption in the human vitreous was created. Major inputs included ascorbate-mediated oxygen consumption in the vitreous, consumption at the posterior lens surface, and inflow from the retinal vasculature. Concentration-dependent relations were determined from experimental human data or estimated from animal studies, with the impact of all assumptions explored via parameter studies. The model reproduced experimental data in humans, including oxygen partial pressure (Po2) gradients (≈15 mm Hg) across the anterior-posterior extent of the vitreous body, higher oxygen levels at the pars plana relative to the vitreous core, increases in Po2 near the lens after cataract surgery, and equilibration in the vitreous chamber following vitrectomy. Loss of the antioxidative capacity of ascorbate increases oxygen levels 3-fold at the lens surface. Homogeneous vitreous degeneration (liquefaction), but not partial posterior vitreous detachment, greatly increases oxygen exposure to the lens. Ascorbate content and the structure of the vitreous gel are critical determinants of lens oxygen exposure. Minimally invasive surgery and restoration of vitreous structure warrant further attention as strategies for preventing nuclear cataracts.
Fixed point and anomaly mediation in partial {\\boldsymbol{N}}=2 supersymmetric standard models
NASA Astrophysics Data System (ADS)
Yin, Wen
2018-01-01
Motivated by the simple toroidal compactification of extra-dimensional SUSY theories, we investigate a partial N = 2 supersymmetric (SUSY) extension of the standard model which has an N = 2 SUSY sector and an N = 1 SUSY sector. We point out that below the scale of the partial breaking of N = 2 to N = 1, the ratio of Yukawa to gauge couplings embedded in the original N = 2 gauge interaction in the N = 2 sector becomes greater due to a fixed point. Since at the partial breaking scale the sfermion masses in the N = 2 sector are suppressed due to the N = 2 non-renormalization theorem, the anomaly mediation effect becomes important. If dominant, the anomaly-induced masses for the sfermions in the N = 2 sector are almost UV-insensitive due to the fixed point. Interestingly, these masses are always positive, i.e. there is no tachyonic slepton problem. From an example model, we show interesting phenomena differing from ordinary MSSM. In particular, the dark matter particle can be a sbino, i.e. the scalar component of the N = 2 vector multiplet of {{U}}{(1)}Y. To obtain the correct dark matter abundance, the mass of the sbino, as well as the MSSM sparticles in the N = 2 sector which have a typical mass pattern of anomaly mediation, is required to be small. Therefore, this scenario can be tested and confirmed in the LHC and may be further confirmed by the measurement of the N = 2 Yukawa couplings in future colliders. This model can explain dark matter, the muon g-2 anomaly, and gauge coupling unification, and relaxes some ordinary problems within the MSSM. It is also compatible with thermal leptogenesis.
Lynch, C D; Singhrao, H; Addy, L D; Gilmour, A S M
2010-12-01
All areas of the practice of dentistry are evolving at a considerable pace. One area in particular which has seen a rapid revolution is the oral rehabilitation of partially dentate adults. The aim of this study was to describe the contemporary teaching of fixed partial dentures (FPDs) in dental schools in Ireland and the United Kingdom. An online questionnaire which sought information in relation to the current teaching of FPDs was developed and distributed to 15 Irish and UK dental schools with undergraduate teaching programmes in Spring 2009. Responses were received from 12 schools (response rate=80%). All schools offer teaching programmes in relation to FPDs. The number of hours devoted to pre-clinical/phantom head teaching of FPDs ranged from 3 to 42h (mean: 16h). The staff/student ratio for pre-clinical teaching courses in FPDs ranged from 1:6 to 1:18 (mode: 1:12). Cantilever resin-retained FPDs were the most popular type of FPD provided clinically (average=0·83 per school; range=1-2). Five schools (42%) report that they have requirements (e.g. targets, quotas, competencies) which students must complete prior to graduation in relation to FPDs. Fixed partial dentures form an important part of the undergraduate teaching programme in UK and Irish dental schools. While this teaching is subjected to contemporary pressures such as lack of curriculum time and a lack of available clinical facilities and teachers, there is evidence that teaching programmes in this area are evolving and are sensitive to current clinical practice trends and evidence-based practice. © 2010 Blackwell Publishing Ltd.
"Hidden" bone metastasis from thyroid carcinoma: a clinical note.
Sioka, C; Skarulis, M C; Tulloch-Reid, M K; Heiss, J D; Reynolds, J C
2014-01-01
The (131)I-iodide ((131)I) whole-body scan, for thyroid carcinoma is at times difficult to interpret. In a diagnostic whole body (131)I scan of a patient with follicular carcinoma, a posterior skull lesion was partially hidden by overlapping facial structures. On lateral head view, the abnormality was clearly evident. SPECT/CT and MRI showed the lesion originated in the occipital bone and had enlarged into the posterior fossa. The mass was surgically removed and the patient received (131)I therapy for residual tissue. The study demonstrates a pitfall in the reading of two dimensional radioiodine images which can be overcome by SPECT or lateral imaging. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.
Comparison of robot surgery modular and total knee arthroplasty kinematics.
Yildirim, Gokce; Fernandez-Madrid, Ivan; Schwarzkopf, Ran; Walker, Peter S; Karia, Raj
2014-04-01
The kinematics of seven knee specimens were measured from 0 to 120 degrees flexion using an up-and-down crouching machine. Motion was characterized by the positions of the centers of the lateral and medial femoral condyles in the anterior-posterior direction relative to a fixed tibia. A modular unicompartmental knee, trochlea flange, and patella resurfacing (multicompartmental knee [MCK] system) were implanted using a surgeon-interactive robot system that provided accurate surface matching. The MCK was tested, followed by standard cruciate retaining (CR) and posterior stabilized (PS) knees. The motion of the MCK was close to anatomic, especially on the medial side, in contrast to the CR and PS knees that showed abnormal motion features. Such a modular knee system, accurately inserted, has the potential for close to normal function in clinical application. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Enamel thickness of the posterior dentition: its implications for nonextraction treatment.
Stroud, J L; English, J; Buschang, P H
1998-04-01
This study describes mesial and distal enamel thickness of the permanent posterior mandibular dentition. The sample comprised 98 Caucasian adults (59 males, 39 females) 20 to 35 years old. Bitewing radiographs of the right permanent mandibular premolars and first and second molars were illuminated and transferred to a computer at a fixed magnification via a video camera. Enamel and dentin thicknesses were identified and digitized on the plane representing the maximum mesiodistal diameter of each tooth. The results showed that there were no significant sex differences in either mesial or distal enamel thickness. Enamel on the second molars was significantly thicker (0.3 to 0.4 mm) than enamel on the premolars. Distal enamel was significantly thicker than mesial enamel. There was approximately 10 mm of total enamel on the four teeth combined. Assuming 50% enamel reduction, the premolars and molars should provide 9.8 mm of additional space for realignment of mandibular teeth.
Siegert, Ralf
2004-11-01
Many techniques have been described for the correction of protruding ears. Most of them concentrate on correcting the form and position of auricular cartilage. The lobule is a soft tissue structure. Skin resections of its posterior surface have been propagated for the correction of its position; however, these cause tension on the wound and might increase the already relatively high risk for the development of keloids. We have modified the technique for correcting the protruding lobule for its exact positioning and minimizing the risk for relapse and keloids. Starting from the incision performed for the anthelix plasty, a subcutaneous pocket is prepared between the anterior and posterior sides of the lobule. Afterwards, the subcutaneous layer of the postlobular skin is adjusted and fixed to the cartilage of the conchal cavum with a special mattress suture. This technique is a refinement of otoplasty for bat ears. It is indicated for precise modification of form and position of protruding lobules.
Pure Varus Injury to the Knee Joint.
Yoo, Jae Ho; Lee, Jung Ha; Chang, Chong Bum
2015-06-01
A 30-year-old male was involved in a car accident. Radiographs revealed a depressed marginal fracture of the medial tibial plateau and an avulsion fracture of the fibular head. Magnetic resonance imaging showed avulsion fracture of Gerdy's tubercle, injury to the posterior cruciate ligament (PCL), posterior horn of the medial meniscus, and the attachments of the lateral collateral ligament and the biceps femoris tendon. The depressed fracture of the medial tibial plateau was elevated and stabilized using a cannulated screw and washer. The injured lateral and posterolateral corner (PLC) structures were repaired and augmented by PLC reconstruction. However, the avulsion fracture of Gerdy's tubercle was not fixed because it was minimally displaced and the torn PCL was also not repaired or reconstructed. We present a unique case of pure varus injury to the knee joint. This case contributes to our understanding of the mechanism of knee injury and provides insight regarding appropriate treatment plans for this type of injury.
2013-01-01
Background To develop a side-view imaging technique for observing the dynamic behavior of posterior chamber structures (PCSs) in porcine eyes which mimics closed-eye cataract surgery in humans. Methods Enucleated porcine eyes were placed into liquid nitrogen for 5 seconds and immediately bisected at about a 45-degree angle to the equatorial plane. The anterior portion was attached firmly to a glass slide with superglue and sprinkled with wheat flour. Phacoemulsification and aspiration (PEA) was performed as in humans on 10 consecutive porcine eyes. The movements of the PCSs were monitored through the glass slide with a high-resolution video camera set below the cut surface of the eye. The intraocular pressure (IOP) was monitored during the surgery. The highest IOP, operation time, and volume of irrigation fluid of 10 whole eyes were compared to that obtained from the bisected eyes glued to a glass slide. In a second set of experiments, the strength of the seal between the bisected eye and the glass slide was tested in three sets of eyes: 1) frozen eye fixed with superglue with wheat flour for 3 min; 2) frozen eye fixed with superglue for 3 min; and 3) non-frozen eye fixed with superglue for 30 min. The highest IOP that led to a disruption of the seal was compared among the three groups. Results PEA was successfully performed on 9 of 10 (90%) eyes with the movements of the PCSs clearly observed. The average maximum intraocular pressure of the 9 bisected eyes was 55.8 ± 4.7 mmHg and that for the 10 unbisected eyes was 55.3 ± 5.0 mmHg (P = 0.650). The frozen eye fixed with superglue in combination with wheat flour (Group 1) had the strongest sealing strength with an average IOP at the breaking point of 117.3 ± 36.2 mmHg. Conclusions Our side-view imaging technique can be used to evaluate the changes of the PCSs during intraocular surgery and for surgical training of new residents. PMID:24053470
Vertullo, Christopher J; Lewis, Peter L; Lorimer, Michelle; Graves, Stephen E
2017-07-05
Controversy still exists as to the optimum management of the posterior cruciate ligament (PCL) in total knee arthroplasty. Surgeons can choose to kinematically substitute the PCL with a posterior-stabilized total knee replacement or alternatively to utilize a cruciate-retaining, also known as minimally stabilized, total knee replacement. Proponents of posterior-stabilized total knee replacement propose that the reported lower survivorship in registries when directly compared with minimally stabilized total knee replacement is due to confounders such as selection bias because of the preferential usage of posterior-stabilized total knee replacement in more complex or severe cases. In this study, we aimed to eliminate these possible confounders by performing an instrumental variable analysis based on surgeon preference to choose either posterior-stabilized or minimally stabilized total knee replacement, rather than the actual prosthesis received. Cumulative percent revision, hazard ratio (HR), and revision diagnosis data were obtained from the Australian Orthopaedic Association National Joint Replacement Registry from September 1, 1999, to December 31, 2014, for 2 cohorts of patients, those treated by high-volume surgeons who preferred minimally stabilized replacements and those treated by high-volume surgeons who preferred posterior-stabilized replacements. All patients had a diagnosis of osteoarthritis and underwent fixed-bearing total knee replacement with patellar resurfacing. At 13 years, the cumulative percent revision was 5.0% (95% confidence interval [CI], 4.0% to 6.2%) for the surgeons who preferred the minimally stabilized replacements compared with 6.0% (95% CI, 4.2% to 8.5%) for the surgeons who preferred the posterior-stabilized replacements. The revision risk for the surgeons who preferred posterior-stabilized replacements was significantly higher for all causes (HR = 1.45 [95% CI, 1.30 to 1.63]; p < 0.001), for loosening or lysis (HR = 1.93 [95% CI, 1.58 to 2.37]; p < 0.001), and for infection (HR = 1.51 [95% CI, 1.25 to 1.82]; p < 0.001). This finding was irrespective of patient age and was evident with cemented fixation and with both cross-linked polyethylene and non-cross-linked polyethylene. However, the higher revision risk was only evident in male patients. There was a 45% higher risk of revision for the patients of surgeons who preferred a posterior-stabilized total knee replacement compared with the patients of surgeons who preferred a minimally stabilized total knee replacement. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Li, Bingyi; Chen, Liang; Wei, Chunpeng; Xie, Yizhuang; Chen, He; Yu, Wenyue
2017-01-01
With the development of satellite load technology and very large scale integrated (VLSI) circuit technology, onboard real-time synthetic aperture radar (SAR) imaging systems have become a solution for allowing rapid response to disasters. A key goal of the onboard SAR imaging system design is to achieve high real-time processing performance with severe size, weight, and power consumption constraints. In this paper, we analyse the computational burden of the commonly used chirp scaling (CS) SAR imaging algorithm. To reduce the system hardware cost, we propose a partial fixed-point processing scheme. The fast Fourier transform (FFT), which is the most computation-sensitive operation in the CS algorithm, is processed with fixed-point, while other operations are processed with single precision floating-point. With the proposed fixed-point processing error propagation model, the fixed-point processing word length is determined. The fidelity and accuracy relative to conventional ground-based software processors is verified by evaluating both the point target imaging quality and the actual scene imaging quality. As a proof of concept, a field- programmable gate array—application-specific integrated circuit (FPGA-ASIC) hybrid heterogeneous parallel accelerating architecture is designed and realized. The customized fixed-point FFT is implemented using the 130 nm complementary metal oxide semiconductor (CMOS) technology as a co-processor of the Xilinx xc6vlx760t FPGA. A single processing board requires 12 s and consumes 21 W to focus a 50-km swath width, 5-m resolution stripmap SAR raw data with a granularity of 16,384 × 16,384. PMID:28672813
Yang, Chen; Li, Bingyi; Chen, Liang; Wei, Chunpeng; Xie, Yizhuang; Chen, He; Yu, Wenyue
2017-06-24
With the development of satellite load technology and very large scale integrated (VLSI) circuit technology, onboard real-time synthetic aperture radar (SAR) imaging systems have become a solution for allowing rapid response to disasters. A key goal of the onboard SAR imaging system design is to achieve high real-time processing performance with severe size, weight, and power consumption constraints. In this paper, we analyse the computational burden of the commonly used chirp scaling (CS) SAR imaging algorithm. To reduce the system hardware cost, we propose a partial fixed-point processing scheme. The fast Fourier transform (FFT), which is the most computation-sensitive operation in the CS algorithm, is processed with fixed-point, while other operations are processed with single precision floating-point. With the proposed fixed-point processing error propagation model, the fixed-point processing word length is determined. The fidelity and accuracy relative to conventional ground-based software processors is verified by evaluating both the point target imaging quality and the actual scene imaging quality. As a proof of concept, a field- programmable gate array-application-specific integrated circuit (FPGA-ASIC) hybrid heterogeneous parallel accelerating architecture is designed and realized. The customized fixed-point FFT is implemented using the 130 nm complementary metal oxide semiconductor (CMOS) technology as a co-processor of the Xilinx xc6vlx760t FPGA. A single processing board requires 12 s and consumes 21 W to focus a 50-km swath width, 5-m resolution stripmap SAR raw data with a granularity of 16,384 × 16,384.
Three-year clinical performance of cast gold vs ceramic partial crowns.
Federlin, M; Wagner, J; Männer, T; Hiller, K-A; Schmalz, G
2007-12-01
Cast gold partial crowns (CGPC) and partial ceramic crowns (PCC) are both accepted for restoring posterior teeth with extended lesions today. However, as esthetics in dentistry becomes increasingly important, CGPC are being progressively replaced by PCC. The aim of the present prospective split-mouth study was the comparison of the clinical performance of PCC and CGPC after 3 years of clinical service. Twenty-eight patients (11 men and 17 women) participated in the 3-year recall with a total of 56 restorations. In each patient, one CGPC (Degulor C) and one PCC (Vita Mark II ceramic/Cerec III) had been inserted at baseline. CGPC were placed using a zinc phosphate cement (Harvard); PCC were adhesively luted (Variolink II/Excite). All restorations were clinically assessed using modified US Public Health Service (USPHS) criteria at baseline, 1 year, 2 years, and 3 years after insertion. Twenty-eight CGPC and 14 PCC were placed in molars, and 14 PCC were placed in premolars. Early data were reported previously under the same study design. After 3 years, the evaluation according to USPHS criteria revealed no statistically significant differences between both types of restorations with the exception of marginal adaptation and marginal discoloration: A statistically significant difference within the PCC group (baseline/3 years) was determined for the criterion marginal adaptation. For the 3-year recall period, overall failure was 0% for CGPC and 6.9% for PCC. At 3 years, PCC meet American Dental Association Acceptance Guidelines criteria for tooth-colored restorative materials for posterior teeth.
SINGH, G. D.; McNAMARA JR, J. A.; LOZANOFF, S.
1997-01-01
This study determines deformations of the midface that contribute to a class III appearance, employing thin-plate spline analysis. A total of 135 lateral cephalographs of prepubertal children of European-American descent with either class III malocclusions or a class I molar occlusion were compared. The cephalographs were traced and checked, and 7 homologous landmarks of the midface were identified and digitised. The data sets were scaled to an equivalent size and subjected to Procrustes analysis. These statistical tests indicated significant differences (P<0.05) between the averaged class I and class III morphologies. Thin-plate spline analysis indicated that both affine and nonaffine transformations contribute towards the total spline for the averaged midfacial configuration. For nonaffine transformations, partial warp 3 had the highest magnitude, indicating the large scale deformations of the midfacial configuration. These deformations affected the palatal landmarks, and were associated with compression of the midfacial complex in the anteroposterior plane predominantly. Partial warp 4 produced some vertical compression of the posterior aspect of the midfacial complex whereas partial warps 1 and 2 indicated localised shape changes of the maxillary alveolus region. Large spatial-scale deformations therefore affect the midfacial complex in an anteroposterior axis, in combination with vertical compression and localised distortions. These deformations may represent a developmental diminution of the palatal complex anteroposteriorly that, allied with vertical shortening of midfacial height posteriorly, results in class III malocclusions with a retrusive midfacial profile. PMID:9449078
Singh, G D; McNamara, J A; Lozanoff, S
1997-11-01
This study determines deformations of the midface that contribute to a class III appearance, employing thinplate spline analysis. A total of 135 lateral cephalographs of prepubertal children of European-American descent with either class III malocclusions or a class I molar occlusion were compared. The cephalographs were traced and checked, and 7 homologous landmarks of the midface were identified and digitised. The data sets were scaled to an equivalent size and subjected to Procrustes analysis. These statistical tests indicated significant differences (P < 0.05) between the averaged class I and class III morphologies. Thinplate spline analysis indicated that both affine and nonaffine transformations contribute towards the total spline for the averaged midfacial configuration. For nonaffine transformations, partial warp 3 had the highest magnitude, indicating the large scale deformations of the midfacial configuration. These deformations affected the palatal landmarks, and were associated with compression of the midfacial complex in the anteroposterior plane predominantly. Partial warp 4 produced some vertical compression of the posterior aspect of the midfacial complex whereas partial warps 1 and 2 indicated localised shape changes of the maxillary alveolus region. large spatial-scale deformations therefore affect the midfacial complex in an anteroposterior axis, in combination with vertical compression and localised distortions. These deformations may represent a developmental diminution of the palatal complex anteroposteriorly that, allied with vertical shortening of midfacial height posteriorly, results in class III malocclusions with a retrusive midfacial profile.
Freutel, Maren; Seitz, Andreas M; Ignatius, Anita; Dürselen, Lutz
2015-01-01
Numerous studies investigated the reasons for premature osteoarthritis due to partial meniscectomy (PM). However, the influence of meniscectomy on attachment forces and superficial strain of the tibial meniscus is unclear. It is hypothesised that these parameters depend on the degree of PM. Six porcine medial menisci were placed in a custom made apparatus, and each meniscal attachment was connected to a force sensor. After printing markers onto the tibial meniscal surfaces, the menisci were positioned on a glass plate enabling optical superficial strain measurement. Additionally, contact area and pressure were investigated. Each meniscus was axially loaded up to 650 N using its respective femoral condyle. Testing was conducted intact and after 50 and 75% PM of the posterior horn and extending 75% PM to the anterior horn. With increasing meniscectomy, the attachment forces decreased anteriorly by up to 17% (n.s.) and posteriorly by up to 55% (p = 0.003). The circumferential strain in the peripheral meniscal zones was not affected by the meniscectomy, while in some meniscal zones the radial strain changed from compression to tension. Contact area decreased by up to 23% (p = 0.01), resulting in an increase in 40% (p = 0.02) for the maximum contact pressure. Partial meniscectomy significantly alters the loading situation of the meniscus and its attachments. Specifically, the attachment forces decreased with increasing amount of meniscal tissue loss, which reflects the impaired ability of the meniscus to transform axial joint load into meniscal hoop stress.
Magnetic resonance imaging of the posterior cruciate ligament in flexion.
Craddock, William; Smithers, Troy; Harris, Craig; du Moulin, William; Molnar, Robert
2018-06-01
Posterior cruciate ligament (PCL) injuries of the knee are common and sometimes difficult to diagnose. Magnetic resonance imaging (MRI), performed using standard orthogonal plane views, is the investigation of choice. It can be particularly difficult to differentiate acute partial and complete tears and identify elongation of chronic healed tears. The aim of the paper is to describe a new method of positioning the patient with the knee flexed at 90°, allowing the PCL to be visualised in a position of greatest length and tension which may assist in differentiating and identifying these injuries. Four symptomatic patients with suspected PCL injuries, two acute and two chronic, were MRI scanned using a routine protocol with the knee in extension before performing oblique sagittal fast spin-echo (FSE) proton-density (PD) sequences with the knee positioned in 90° of flexion. The appearance of the PCLs were then qualitatively assessed. MRI scanning with the knee in flexion identified more extensive PCL injury than standard imaging. In the two patients with acute injuries, partial tears on the standard orthogonal plane views were found to be complete ruptures. In the two patients with chronic injuries, elongation of the PCL not identifiable on the standard orthogonal plane views was apparent. MRI scanning of the PCL with the knee flexed at 90° may help in differentiating partial and complete ruptures of the PCL and identifying elongation of the PCL in chronic injuries. Copyright © 2018 Elsevier B.V. All rights reserved.
Aquarium Portal Technique for PASTA Lesion Repair.
Meyer, Dominik C; Gerber, Christian; Familiari, Filippo
2017-10-01
The simultaneous arthroscopic exposure of the subacromial and intra-articular space of the shoulder is challenging in the presence of only partial-thickness rotator cuff tears. We present our experience and method of entering the joint through the opened rotator cuff interval from an anterosuperior portal between the coracoid process and anterior acromion. With moderate (approximately 30°) abduction and external rotation, the rotator interval opens readily, offering a view with the camera toward the anterior edge of the supraspinatus tendon. An anterior view on the anterior leading edge of the supraspinatus tendon is obtained, showing the subacromial space above and the glenohumeral space below the tendon, similar to the view in an aquarium. The rotator cuff can be elevated using a rod inserted intra-articularly from posterior, whereas anchors and other instruments may be inserted from lateral. This approach offers the advantages of full exposure of the posterior undersurface of the rotator cuff insertion; a convenient approximately 90° angle between the camera and instruments; and no need to change portals for anchor placement, tendon stitching, or suture handling. The objective of this Technical Note is to describe our arthroscopic repair approach (aquarium technique) to PASTA (partial articular supraspinatus tendon avulsion) lesions.
Orbital reconstruction in the dog, cat, and horse.
Wallin-Håkansson, Nils; Berggren, Karin
2017-07-01
To describe an adaptable method for reconstruction of the orbit following partial orbitectomy. One horse, one cat, and four dogs. Following partial orbitectomy for removal of bone and soft tissue affected by pathologic processes, reconstruction was achieved. Cerclage wires were used to reconstitute the orbital rim and other salient facial contours involved in excisions. These wires were then covered with a prolene mesh, first inside the orbit and then outwards over the affected extraorbital areas. Thereafter, a collagen sheet was placed over the mesh. Finally, subcutis and skin were closed over the construct. All operated eyes remained visual with normal position, direction, and mobility. Eyelid function, tear production, and nasolacrimal function were preserved. Side effects were mild and temporary, but animals requiring a lateral-posterior surgical approach experienced concavity to the side of the head posterior to the orbital ligament region. One bone tumor out of three recurred. The reconstruction method presented offers excellent results tectonically, cosmetically, and functionally, even following extensive orbitectomy. By adapted application of three reconstruction steps using readily available materials, large defects may be surgically repaired. Once orbitectomy is mastered, reconstruction requires no additional specialized techniques or equipment. © 2016 American College of Veterinary Ophthalmologists.
STS-26 crew trains in JSC fixed-based (FB) shuttle mission simulator (SMS)
1987-10-20
S87-46304 (20 Oct 1987) --- Astronauts Frederick H. (Rick) Hauck, left, STS-26 commander, and Richard O. Covey, pilot, man their respective stations in the Shuttle mission simulator (fixed base) at the Johnson Space Center. A simulation for their anticipated June 1988 flight aboard the space shuttle Discovery began Oct. 20. Astronaut David C. Hilmers, one of three mission specialists for the flight, is partially visible in the foreground.
Lew, P. C.; Briggs, C. A.
1997-05-01
SUMMARY. The slump test has been used routinely to differentiate low back pain due to involvement of neural structures from low back pain attributable to other factors. It is also said to differentiate between posterior thigh pain due to neural involvement from that due to hamstring injury. If changes in cervical position affect the hamstring muscles, differential diagnosis is confounded. Posterior thigh pain caused by the cervical component of the slump could then be caused either by increased tension on neural structures or increased tension in the hamstrings themselves. The aim of this study was to determine whether changing the cervical position during slump altered posterior thigh pain and/or the tension in the hamstring muscle. Asymptomatic subjects aged between 18 and 30 years were tested. A special fixation device was engineered to fix the trunk, pelvis and lower limb. Pain levels in cervical flexion and extension were assessed by visual analogue scale. Fixation was successful in that there were no significant differences in position of the pelvis or knee during changes in cervical position. Averaged over the group, there was a 40% decrease (P < 0.05) in posterior thigh pain with cervical extension. There were no significant differences in hamstring electromyographic readings during the cervical movements. This indicated that: (1) cervical movement did not change hamstring muscle tension, and (2) the change in experimentally induced pain during cervical flexion was not due to changes in the hamstring muscle. This conclusion supports the view that posterior thigh pain caused by the slump test and relieved by cervical extension arises from neural structures rather than the hamstring muscle. Copyright 1997 Harcourt Publishers Ltd.
Ioannidis, Alexis; Bindl, Andreas
2016-04-01
Only a few studies exist, which assess the clinical long-term behavior of all-ceramic FDPs in the posterior region. The aim of the present prospective clinical study was to evaluate the clinical performance of posterior three-unit FDPs manufactured from Y-TZP after a service period up to 10 years. 55 patients received 59 three-unit FDPs in the posterior region of the maxilla or mandible. Abutment teeth were prepared and full-arch impressions were taken. Definitive casts were fabricated and optically scanned. Frameworks were fabricated with computer-aided design (CAD) and manufacturing (CAM) technology. Y-TZP frameworks were veneered and adhesively luted to the abutment teeth. Baseline and follow-up examinations (service time: ≥ 48 months) were recorded by applying modified United States Public Health Services (USPHS) rating criteria. Cumulative survival rate was analyzed with Kaplan-Meier. Percentage of biological and technical complication was calculated. Fifty-three patients with 57 FDPs attended the last follow-up visit and a mean observation period of the remaining was 6.3 ± 1.9 years was calculated. Biological complications occurred in 17.5%, technical complications in 28% of the FDPs. The 10-year cumulative survival rate amounted 85.0%. Three FDPs failed to survive, two due to a root fracture of the abutment tooth and one due to secondary caries. Three-unit FDPs made from Y-TZP, veneered with ceramic offer a treatment option with a high rate of chipping. However, the manufacturing processes nowadays are modified in order to avoid this complication. The results of the present investigation suggest that three-unit Y-TZP posterior FDPs may are a possible treatment option. However, a high rate of chipping can be expected. Copyright © 2016. Published by Elsevier Ltd.
Miyazaki, Masashi; Kanezaki, Shozo; Notani, Naoki; Ishihara, Toshinobu; Tsumura, Hiroshi
2017-01-01
Abstract Rationale: Fixed thoracolumbar kyphosis with spinal stenosis in adult patients with achondroplasia presents a challenging issue. We describe the first case in which spondylectomy and minimally invasive lateral access interbody arthrodesis were used for the treatment of fixed severe thoracolumbar kyphosis and lumbar spinal canal stenosis in an adult with achondroplasia. Patient concerns: A 61-year-old man with a history of achondroplastic dwarfism presented with low back pain and radiculopathy and neurogenic claudication. Diagnoses: Plain radiographs revealed a high-grade thoracolumbar kyphotic deformity with diffuse degenerative changes in the lumbar spine. The apex was located at L2, the local kyphotic angle from L1 to L3 was 105°, and the anterior area was fused from the L1 to L3 vertebrae. MRI revealed significant canal and lateral recess stenosis secondary to facet hypertrophy. Interventions: We planned a front-back correction of the anterior and posterior spinal elements. We first performed anterior release at the fused part from L1 to L3 and XLIF at L3/4 and L4/5. Next, the patient was placed in the prone position. Spondylectomy at the L2 vertebra and posterior fusion from T10 to L5 were performed. Postoperative radiographs revealed L1 to L3 kyphosis of 32°. Outcomes: No complications occurred during or after surgery. Postoperatively, the patient's low back pain and neurological claudication were resolved. No worsening of kyphosis was observed 24 months postoperatively. Lessons: Circumferential decompression of the spinal cord at the apical vertebral level and decompression of lumbar canal stenosis were necessary. Front-back correction of the anterior and posterior spinal elements via spondylectomy and lateral lumbar interbody fusion is a reasonable surgical option for thoracolumbar kyphosis and developmental canal stenosis in patients with achondroplasia. PMID:29245270
Takeuchi, Kenji; Izumi, Maya; Furuta, Michiko; Takeshita, Toru; Shibata, Yukie; Kageyama, Shinya; Ganaha, Seijun; Yamashita, Yoshihisa
2015-01-01
Early detection and subsequent reduction of modifiable risk factors for cognitive decline is important for extending healthy life expectancy in the currently aging society. Although a recent increase in studies on the state or number of the teeth and cognitive function, few studies have focused on the association between posterior teeth occlusion necessary to maintain chewing function and cognitive function among older adults. This study examined the association between posterior teeth occlusion and cognitive function in nursing home older residents. In this cross-sectional study, 279 residents aged ≥60 years from eight nursing homes in Aso City, Japan participated in cognitive function and dental status assessments and completed a comprehensive questionnaire survey in 2014. Cognitive function was measured using a Mini-Mental State Examination (MMSE). Posterior teeth occlusion was assessed using a total number of functional tooth units (total-FTUs), depending on the number and location of the remaining natural and artificial teeth on implant-supported, fixed, and removable prostheses. Linear regression models were used to assess univariate and multivariate associations between total-FTUs and MMSE scores. Models were sequentially adjusted for demographic characteristics, number of natural teeth, socioeconomic status, health behaviors, comorbidities, physical function, and nutritional status. Among the 200 residents included in our analysis, mean MMSE scores and total-FTUs were 11.0 ± 8.6 and 9.3 ± 4.6, respectively. Higher total-FTUs were significantly associated with higher MMSE scores after adjustment for demographics and teeth number (B = 0.48, 95% confidence interval [CI] = 0.22–0.74). The association remained significant even after adjustment for all covariates (B = 0.25, 95% CI = 0.01–0.49). The current findings demonstrated that loss of posterior teeth occlusion was independently associated with cognitive decline in nursing home older residents in Japan. Maintenance and restoration of posterior teeth occlusion may be a preventive factor against cognitive decline in aged populations. PMID:26512900
Value of Information Analysis for Time-lapse Seismic Data by Simulation-Regression
NASA Astrophysics Data System (ADS)
Dutta, G.; Mukerji, T.; Eidsvik, J.
2016-12-01
A novel method to estimate the Value of Information (VOI) of time-lapse seismic data in the context of reservoir development is proposed. VOI is a decision analytic metric quantifying the incremental value that would be created by collecting information prior to making a decision under uncertainty. The VOI has to be computed before collecting the information and can be used to justify its collection. Previous work on estimating the VOI of geophysical data has involved explicit approximation of the posterior distribution of reservoir properties given the data and then evaluating the prospect values for that posterior distribution of reservoir properties. Here, we propose to directly estimate the prospect values given the data by building a statistical relationship between them using regression. Various regression techniques such as Partial Least Squares Regression (PLSR), Multivariate Adaptive Regression Splines (MARS) and k-Nearest Neighbors (k-NN) are used to estimate the VOI, and the results compared. For a univariate Gaussian case, the VOI obtained from simulation-regression has been shown to be close to the analytical solution. Estimating VOI by simulation-regression is much less computationally expensive since the posterior distribution of reservoir properties given each possible dataset need not be modeled and the prospect values need not be evaluated for each such posterior distribution of reservoir properties. This method is flexible, since it does not require rigid model specification of posterior but rather fits conditional expectations non-parametrically from samples of values and data.
Convergence analysis of surrogate-based methods for Bayesian inverse problems
NASA Astrophysics Data System (ADS)
Yan, Liang; Zhang, Yuan-Xiang
2017-12-01
The major challenges in the Bayesian inverse problems arise from the need for repeated evaluations of the forward model, as required by Markov chain Monte Carlo (MCMC) methods for posterior sampling. Many attempts at accelerating Bayesian inference have relied on surrogates for the forward model, typically constructed through repeated forward simulations that are performed in an offline phase. Although such approaches can be quite effective at reducing computation cost, there has been little analysis of the approximation on posterior inference. In this work, we prove error bounds on the Kullback-Leibler (KL) distance between the true posterior distribution and the approximation based on surrogate models. Our rigorous error analysis show that if the forward model approximation converges at certain rate in the prior-weighted L 2 norm, then the posterior distribution generated by the approximation converges to the true posterior at least two times faster in the KL sense. The error bound on the Hellinger distance is also provided. To provide concrete examples focusing on the use of the surrogate model based methods, we present an efficient technique for constructing stochastic surrogate models to accelerate the Bayesian inference approach. The Christoffel least squares algorithms, based on generalized polynomial chaos, are used to construct a polynomial approximation of the forward solution over the support of the prior distribution. The numerical strategy and the predicted convergence rates are then demonstrated on the nonlinear inverse problems, involving the inference of parameters appearing in partial differential equations.
Sessa, Pasquale; Fioravanti, Giulio; Giannicola, Giuseppe; Cinotti, Gianluca
2015-01-01
In cruciate retaining total knee arthroplasty (TKA), a partial avulsion of PCL may occur when en-bloc tibial osteotomy is performed. We evaluated the effects of a tibial cut performed with different degrees of posterior slope on PCL insertion and whether the results are affected by the sagittal inclination of the patient's tibial plateau. We selected 83 MRIs of knees showing mild or no degenerative changes. The effects of a simulated tibial cut performed with a posterior slope of 0°, 3°, 5° and parallel to the patient's tibial plateau inclination on PCL insertion in the proximal tibia were investigated. The results were correlated with the degree of posterior inclination of the tibial plateau. Every angle we used for the tibial cut caused a PCL avulsion greater than 50%. The percentage of PCL avulsion significantly increased with increasing the posterior slope of the tibial cut. Patients with sagittal tibial plateau inclination <5° showed greater PCL avulsion than those with sagittal inclination >8°. Most of the PCL insertion is likely to be sacrificed when resection of the proximal tibia is performed en-block. The risk of PCL avulsion is reduced in patients showing a marked posterior inclination of the tibial plateau, but even in this group of patients a surgical technique aimed at sparing most of the PCL insertion is necessary. Copyright © 2014 Elsevier B.V. All rights reserved.
Gipouloux, J D; Hakim, J
1975-10-13
The experimental results of cranio-caudal reversal and dorso-ventral reversal of the lateral mesoblast of the toad early neurula prove that, at this stage, the cranio-caudal polarity of this tissue is fixed but not the dorso-ventral one. External factors are responsible for the formation of mesonephric, adrenal and gonadal medullary anlage by the lateral mesoblast.
Traumatic fracture-dislocation of the hip following rugby tackle: a case report.
Venkatachalam, Santosh; Heidari, Nima; Greer, Tony
2009-12-15
Posterior fracture-dislocation of hip is uncommonly encountered in rugby injuries. We report such a case in an adult while playing rugby. The treating orthopaedician can be caught unaware and injuries in such sports can be potentially misdiagnosed as hip sprains. Immediate reduction of the dislocation was performed in theatres. The fracture was fixed with two lag screws and a neutralization plate. This led to early rehabilitation and speedy recovery with return to sporting activities by 12 months.
Traumatic fracture-dislocation of the hip following rugby tackle: a case report
2009-01-01
Posterior fracture-dislocation of hip is uncommonly encountered in rugby injuries. We report such a case in an adult while playing rugby. The treating orthopaedician can be caught unaware and injuries in such sports can be potentially misdiagnosed as hip sprains. Immediate reduction of the dislocation was performed in theatres. The fracture was fixed with two lag screws and a neutralization plate. This led to early rehabilitation and speedy recovery with return to sporting activities by 12 months. PMID:20003496
Nee, Derek Evan; Brown, Joshua W.
2013-01-01
Recent theories propose that the prefrontal cortex (PFC) is organized in a hierarchical fashion with more abstract, higher level information represented in anterior regions and more concrete, lower level information represented in posterior regions. This hierarchical organization affords flexible adjustments of action plans based on the context. Computational models suggest that such hierarchical organization in the PFC is achieved through interactions with the basal ganglia (BG) wherein the BG gate relevant contexts into the PFC. Here, we tested this proposal using functional magnetic resonance imaging (fMRI). Participants were scanned while updating working memory (WM) with 2 levels of hierarchical contexts. Consistent with PFC abstraction proposals, higher level context updates involved anterior portions of the PFC (BA 46), whereas lower level context updates involved posterior portions of the PFC (BA 6). Computational models were only partially supported as the BG were sensitive to higher, but not lower level context updates. The posterior parietal cortex (PPC) showed the opposite pattern. Analyses examining changes in functional connectivity confirmed dissociable roles of the anterior PFC–BG during higher level context updates and posterior PFC–PPC during lower level context updates. These results suggest that hierarchical contexts are organized by distinct frontal–striatal and frontal–parietal networks. PMID:22798339
Adaptation of brain functional and structural networks in aging.
Lee, Annie; Ratnarajah, Nagulan; Tuan, Ta Anh; Chen, Shen-Hsing Annabel; Qiu, Anqi
2015-01-01
The human brain, especially the prefrontal cortex (PFC), is functionally and anatomically reorganized in order to adapt to neuronal challenges in aging. This study employed structural MRI, resting-state fMRI (rs-fMRI), and high angular resolution diffusion imaging (HARDI), and examined the functional and structural reorganization of the PFC in aging using a Chinese sample of 173 subjects aged from 21 years and above. We found age-related increases in the structural connectivity between the PFC and posterior brain regions. Such findings were partially mediated by age-related increases in the structural connectivity of the occipital lobe within the posterior brain. Based on our findings, it is thought that the PFC reorganization in aging could be partly due to the adaptation to age-related changes in the structural reorganization of the posterior brain. This thus supports the idea derived from task-based fMRI that the PFC reorganization in aging may be adapted to the need of compensation for resolving less distinctive stimulus information from the posterior brain regions. In addition, we found that the structural connectivity of the PFC with the temporal lobe was fully mediated by the temporal cortical thickness, suggesting that the brain morphology plays an important role in the functional and structural reorganization with aging.
Mai, J G; Gu, C; Lin, X Z; Li, T; Huang, W Q; Wang, H; Tan, X Y; Lin, H; Wang, Y M; Yang, Y Q; Jin, D D; Fan, S C
2017-03-01
Objective: To investigate reduction and fixation of complex acetabular fractures using three-dimensional (3D) printing technique and personalized acetabular wing-plate via lateral-rectus approach. Methods: From March to July 2016, 8 patients with complex acetabular fractures were surgically managed through 3D printing personalized acetabular wing-plate via lateral-rectus approach at Department of Orthopedics, the Third Affiliated Hospital of Southern Medical University. There were 4 male patients and 4 female patients, with an average age of 57 years (ranging from 31 to 76 years). According to Letournel-Judet classification, there were 2 anterior+ posterior hemitransverse fractures and 6 both-column fractures, without posterior wall fracture or contralateral pelvic fracture. The CT data files of acetabular fracture were imported into the computer and 3D printing technique was used to print the fractures models after reduction by digital orthopedic technique. The acetabular wing-plate was designed and printed with titanium. All fractures were treated via the lateral-rectus approach in a horizontal position after general anesthesia. The anterior column and the quadrilateral surface fractures were fixed by 3D printing personalized acetabular wing-plate, and the posterior column fractures were reduction and fixed by antegrade lag screws under direct vision. Results: All the 8 cases underwent the operation successfully. Postoperative X-ray and CT examination showed excellent or good reduction of anterior and posterior column, without any operation complications. Only 1 case with 75 years old was found screw loosening in the pubic bone with osteoporosis after 1 month's follow-up, who didn't accept any treatment because the patient didn't feel discomfort. According to the Matta radiological evaluation, the reduction of the acetabular fracture was rated as excellent in 3 cases, good in 4 cases and fair in 1 case. All patients were followed up for 3 to 6 months and all patients had achieved bone union. According to the modified Merle D'Aubigné and Postel scoring system, 5 cases were excellent, 2 cases were good, 1 case was fair. Conclusions: Surgical management of complex acetabular fracture via lateral-rectus approach combine with 3D printing personalized acetabular wing-plate can effectively improve reduction quality and fixation effect. It will be truly accurate, personalized and minimally invasive.
Mori, Hidetoshi; Kuge, Hiroshi; Tanaka, Tim Hideaki; Taniwaki, Eiichi; Ohsawa, Hideo
2011-06-01
To determine whether any difference exists in responses to indirect moxibustion (IM) relative to thermal stimulation duration. In experiment 1, 9 subjects attended two experimental sessions consisting of single stimulation with IM or triple stimulation with IM, using a crossover design. A K-type thermocouple temperature probe was fixed on the skin surface at the GV14 acupuncture point. IM stimulation was administered to the top of the probe in order to measure the temperature curve. In addition, each subject evaluated his or her subjective feeling of heat on a visual analogue scale after each stimulation. Experiment 2 was conducted on 42 participants, divided into three groups according to the envelope allocation method: single stimulation with IM (n=20), triple stimulation with IM (n=11) and a control group (n=11). A thermograph was used to obtain the skin temperature on the posterior trunk of the participant. To analyse skin temperature, four arbitrary frames (the scapular, interscapular, lumbar and vertebral regions) were made on the posterior trunk. In experiment 1, no significant difference in maximum temperature was found in IM and subjective feeling of heat intensity between single and triple stimulation with IM. In experiment 2, increases in skin temperature occurred on the posterior trunk, but no differences in skin temperature occurred between the groups receiving single and triple stimulation with IM. No difference exists in the skin temperature response to moxibustion between the single and triple stimulation with IM.
An electromyography study of muscular endurance during the posterior shoulder endurance test.
Evans, Neil A; Dressler, Emily; Uhl, Tim
2018-05-31
The primary purpose was to determine if there is a difference between the median frequency slopes of 5 posterior shoulder muscles during the initial portion of the Posterior Shoulder Endurance Test (PSET) at the 90° and 135° shoulder abduction positions. Fifty-five healthy volunteers (31 females) participated. The median frequency of the posterior deltoid (PD), upper trapezius (UT), middle trapezius (MT), lower trapezius (LT), and infraspinatus (INF) was measured during the PSET at 90° and 135° of shoulder abduction. External torque of 13 ± 1 Nm was used for females and 21 ± 1 Nm for males. A fixed effect multi-variable regression model was used to investigate the median frequency slopes. Males and females were analyzed separately. Median frequency slopes demonstrated fatigue in all 5 of the muscles. The PD fatigued greater than the UT in males (p = 0.0215) and greater than the LT in females (p = 0.008). The time to task failure (TTF) was greater at 90° than 135° for females and males (p = 0.016; p = 0.0193) respectively. The PSET causes fatigue in all of the muscles that were tested, with the PD fatiguing at a greater rate compared to one muscle for each sex. This investigation supports using TTF as a clinical measure of shoulder girdle endurance at 90° shoulder abduction. Copyright © 2018. Published by Elsevier Ltd.
Network modulation during complex syntactic processing
den Ouden, Dirk-Bart; Saur, Dorothee; Mader, Wolfgang; Schelter, Björn; Lukic, Sladjana; Wali, Eisha; Timmer, Jens; Thompson, Cynthia K.
2011-01-01
Complex sentence processing is supported by a left-lateralized neural network including inferior frontal cortex and posterior superior temporal cortex. This study investigates the pattern of connectivity and information flow within this network. We used fMRI BOLD data derived from 12 healthy participants reported in an earlier study (Thompson, C. K., Den Ouden, D. B., Bonakdarpour, B., Garibaldi, K., & Parrish, T. B. (2010b). Neural plasticity and treatment-induced recovery of sentence processing in agrammatism. Neuropsychologia, 48(11), 3211-3227) to identify activation peaks associated with object-cleft over syntactically less complex subject-cleft processing. Directed Partial Correlation Analysis was conducted on time series extracted from participant-specific activation peaks and showed evidence of functional connectivity between four regions, linearly between premotor cortex, inferior frontal gyrus, posterior superior temporal sulcus and anterior middle temporal gyrus. This pattern served as the basis for Dynamic Causal Modeling of networks with a driving input to posterior superior temporal cortex, which likely supports thematic role assignment, and networks with a driving input to inferior frontal cortex, a core region associated with syntactic computation. The optimal model was determined through both frequentist and Bayesian model selection and turned out to reflect a network with a primary drive from inferior frontal cortex and modulation of the connection between inferior frontal and posterior superior temporal cortex by complex sentence processing. The winning model also showed a substantive role for a feedback mechanism from posterior superior temporal cortex back to inferior frontal cortex. We suggest that complex syntactic processing is driven by word-order analysis, supported by inferior frontal cortex, in an interactive relation with posterior superior temporal cortex, which supports verb argument structure processing. PMID:21820518
NASA Astrophysics Data System (ADS)
McNabb, Ryan P.; Viehland, Christian; Keller, Brenton; Vann, Robin R.; Izatt, Joseph A.; Kuo, Anthony N.
2017-02-01
Optical coherence tomography (OCT) has revolutionized clinical observation of the eye and is an indispensable part of the modern ophthalmic practice. Unlike many other ophthalmic imaging techniques, OCT provides three-dimensional information about the imaged eye. However, conventional clinical OCT systems image only the anterior or the posterior eye during a single acquisition. Newer OCT systems have begun to image both during the same acquisition but with compromises such as limited field of view in the posterior eye or requiring rapid switching between the anterior and posterior eye during the scan. We describe here the development and demonstration of an OCT system with truly simultaneous imaging of both the anterior and posterior eye capable of imaging the full anterior chamber width and 50° on the retina (macula, optic nerve, and arcades). The whole eye OCT system was developed using custom optics and optomechanics. Polarization was utilized to separate the imaging channels. We utilized a 200kHz swept-source laser (Axsun Technologies) centered at 1040±50nm of bandwidth. The clock signal generated by the laser was interpolated 4x to generate 5504 samples per laser sweep. With the whole eye OCT system, we simultaneously acquired anterior and posterior segments with repeated B-scans as well as three-dimensional volumes from seven healthy volunteers (other than refractive error). On three of these volunteers, whole eye OCT and partial coherence interferometry (LenStar PCI, Haag-Streit) were used to measure axial eye length. We measured a mean repeatability of ±47µm with whole eye OCT and a mean difference from PCI of -68µm.
Wangsrimongkol, Tasanee; Manosudprasit, Montian; Pisek, Poonsak; Leelasinjaroen, Pornnapha
2013-09-01
An 18-year-old Thai man who presented with a secondary cleft palate, maxillary hypoplasia and severe crowding was treated by rapid maxillary expansion and fixed orthodontic appliances. Initial assessment found skeletal Class III malrelationship and dental Class II malocclusion with anterior and bilateral posterior crossbites. Camouflage orthodontic treatment was planned using a rapid maxillary expansion appliance and correcting crowding with extraction all four premolar teeth. A Hyrax appliance and vertical loop arch wire were placed for maxillary arch expansion of 9.5 mms at first molars and canines, and 5.5 mms at the premolars and obtained positive overjet. Both acceptable skeletal and soft tissue relationships and satisfactory occlusion were produced. After 14 months of postoperative follow-up, the occlusal result was stable and no skeletal reversals could be detected.
Posterior Corneal Characteristics of Cataract Patients with High Myopia
Jing, Qinghe; Tang, Yating; Qian, Dongjin; Lu, Yi; Jiang, Yongxiang
2016-01-01
Purpose To evaluate the characteristics of the posterior corneal surface in patients with high myopia before cataract surgery. Methods We performed a cross-sectional study at the Eye and ENT Hospital of Fudan University, Shanghai, China. Corneal astigmatism and axial length were measured with a rotating Scheimpflug camera (Pentacam) and partial coherence interferometry (IOLMaster) in a high-myopia study group of 167 eyes (axial length ≥ 26 mm) and a control group of 150 eyes (axial length > 20 mm and < 25 mm). Results Total corneal astigmatism and anterior corneal astigmatism values were higher in the high-myopia group than in the control group. There was no significant difference in posterior corneal astigmatism between the high-myopia study group and the control group. In the study group, the mean posterior corneal astigmatism (range 0 – −0.9 diopters) was –0.29 diopters (D) ± 0.17 standard deviations (SD). The steep corneal meridian was aligned vertically (60°–120°) in 87.43% of eyes for the posterior corneal surface, and did not change with increasing age. There was a significant correlation (r = 0.235, p = 0.002) between posterior corneal astigmatism and anterior corneal astigmatism, especially when the anterior corneal surface showed with-the-rule (WTR) astigmatism (r = 0.452, p = 0.000). There was a weak negative correlation between posterior corneal astigmatism and age (r = –0.15, p = 0.053) in the high-myopia group. Compared with total corneal astigmatism values, the anterior corneal measurements alone overestimated WTR astigmatism by a mean of 0.27 ± 0.18 D in 68.75% of eyes, underestimated against-the-rule (ATR) astigmatism by a mean of 0.41 ± 0.28 D in 88.89% of eyes, and underestimated oblique astigmatism by a mean of 0.24 ± 0.13 D in 63.64% of eyes. Conclusions Posterior corneal astigmatism decreased with age and remained as ATR astigmatism in most cases of high myopia. There was a significant correlation between posterior corneal astigmatism and anterior corneal astigmatism when anterior corneal astigmatism was WTR. If posterior corneal astigmatism is not accounted for when selecting toric intraocular lenses for high-myopia patients, the use of anterior corneal astigmatism measurements alone will lead to overestimation of WTR astigmatism and underestimation of ATR and oblique astigmatism. PMID:27603713
Posterior Corneal Characteristics of Cataract Patients with High Myopia.
Jing, Qinghe; Tang, Yating; Qian, Dongjin; Lu, Yi; Jiang, Yongxiang
2016-01-01
To evaluate the characteristics of the posterior corneal surface in patients with high myopia before cataract surgery. We performed a cross-sectional study at the Eye and ENT Hospital of Fudan University, Shanghai, China. Corneal astigmatism and axial length were measured with a rotating Scheimpflug camera (Pentacam) and partial coherence interferometry (IOLMaster) in a high-myopia study group of 167 eyes (axial length ≥ 26 mm) and a control group of 150 eyes (axial length > 20 mm and < 25 mm). Total corneal astigmatism and anterior corneal astigmatism values were higher in the high-myopia group than in the control group. There was no significant difference in posterior corneal astigmatism between the high-myopia study group and the control group. In the study group, the mean posterior corneal astigmatism (range 0 - -0.9 diopters) was -0.29 diopters (D) ± 0.17 standard deviations (SD). The steep corneal meridian was aligned vertically (60°-120°) in 87.43% of eyes for the posterior corneal surface, and did not change with increasing age. There was a significant correlation (r = 0.235, p = 0.002) between posterior corneal astigmatism and anterior corneal astigmatism, especially when the anterior corneal surface showed with-the-rule (WTR) astigmatism (r = 0.452, p = 0.000). There was a weak negative correlation between posterior corneal astigmatism and age (r = -0.15, p = 0.053) in the high-myopia group. Compared with total corneal astigmatism values, the anterior corneal measurements alone overestimated WTR astigmatism by a mean of 0.27 ± 0.18 D in 68.75% of eyes, underestimated against-the-rule (ATR) astigmatism by a mean of 0.41 ± 0.28 D in 88.89% of eyes, and underestimated oblique astigmatism by a mean of 0.24 ± 0.13 D in 63.64% of eyes. Posterior corneal astigmatism decreased with age and remained as ATR astigmatism in most cases of high myopia. There was a significant correlation between posterior corneal astigmatism and anterior corneal astigmatism when anterior corneal astigmatism was WTR. If posterior corneal astigmatism is not accounted for when selecting toric intraocular lenses for high-myopia patients, the use of anterior corneal astigmatism measurements alone will lead to overestimation of WTR astigmatism and underestimation of ATR and oblique astigmatism.
Fisher, Joseph A
2016-06-01
Cerebrovascular reactivity (CVR) studies have elucidated the physiology and pathophysiology of cerebral blood flow regulation. A non-invasive, high spatial resolution approach uses carbon dioxide (CO2) as the vasoactive stimulus and magnetic resonance techniques to estimate the cerebral blood flow response. CVR is assessed as the ratio response change to stimulus change. Precise control of the stimulus is sought to minimize CVR variability between tests, and show functional differences. Computerized methods targeting end-tidal CO2 partial pressures are precise, but expensive. Simpler, improvised methods that fix the inspired CO2 concentrations have been recommended as less expensive, and so more widely accessible. However, these methods have drawbacks that have not been previously presented by those that advocate their use, or those that employ them in their studies. As one of the developers of a computerized method, I provide my perspective on the trade-offs between these two methods. The main concern is that declaring the precision of fixed inspired concentration of CO2 is misleading: it does not, as implied, translate to precise control of the actual vasoactive stimulus - the arterial partial pressure of CO2 The inherent test-to-test, and therefore subject-to-subject variability, precludes clinical application of findings. Moreover, improvised methods imply widespread duplication of development, assembly time and costs, yet lack uniformity and quality control. A tabular comparison between approaches is provided. © The Author(s) 2016.
SUEDAM, Valdey; MORETTI, Rafael Tobias; SOUSA, Edson Antonio Capello; RUBO, José Henrique
2016-01-01
ABSTRACT Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. Objectives To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. Material and Methods A U-shaped polyurethane model simulating the mandibular bone containing two implants (Ø 3.75 mm) was used. Six groups were formed according to the alloy’s framework (CoCr or PdAg) and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm). A 300 N load was applied in pre-determined reference points. The tension generated on the mesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. Results Two-way ANOVA and Tukey statistical tests were applied showing significant differences (p<0.05) between the groups. Pearson correlation test (p<0.05) was applied showing positive correlations between the increase of the cantilever arm and the deformation of the peri-implant area. Conclusions This report demonstrated the CoCr alloy shows larger compression values compared to the PdAg alloy for the same distances of cantilever. The point of load application influences the deformation on the peri-implant area, increasing in accordance with the increase of the lever arm. PMID:27119758
[Permanent disability and the insurance estimation process].
Soumah, M M; Mbaye, I; Ndiaye, M; Bah, H; Gaye Fall, M C; Sow, M L
2006-01-01
The casualties are indemnified according to two processes. First by transaction on rate proposition of insurance physicians, and the second process on rate proposition by a medical expert assigned by law-court. Indemnification scale failure justifies the Interafrican Conference of insurance Markets code adoption. Six insurance societies and the Automotive Guarantee Fund were debtors. Only 627 victims had been indemnified between 1986 and 2003. Expert valuations done at forensic medicine service were the support of the investigation. Inquired parameters were insurance societies, regulation type, aftermaths and the retained prejudices. The data collected on computer card have been analyzed by software Epi Info. The partial permanent inabilities fixed since its adoption differ to inabilities fixed before this adoption. Transaction process concerned 567 victims (90.4%). Sixty victims were indemnified by judicial way. According to process type, the rates fixed in judicial process were 61.6% middle permanent partial inabilities. After 1997, there have observed a decrease in the high and middle permanent partial inabilities in the two processes. The appreciation of the pretium doloris is more subjective but must repair the aftermaths. The middle pretium was majority in the two processes, before and after 1997 with a high decrease of the middle pretium in the transaction process (-15.07) and a small pretium increase of 10.98 points. A common scale code has decreased the judicial litigation concerning casualties in spite of scales' limits. Only the patients with important aftermaths arrive in the judicial process since 1997.
Munot, Vimal Kantilal; Nayakar, Ramesh P.; Patil, Raghunath
2017-01-01
The restoration of normal function and esthetic appearance with a dental prosthesis is a major challenge in the rehabilitation of patients who have lost their teeth and surrounding bone because of surgery for oral cyst or tumor. Rehabilitation with fixed or removable prosthesis is even more challenging when the edentulous span is long and the ridge is defective. Anatomic deformities and unfavorable biomechanics encountered in the region of resection add to the misery. In such situation, a fixed-removable prosthesis allows favorable biomechanical stress distribution along with restoration of esthetics, phonetics, comfort, hygiene, and better postoperative care and maintenance. This article describes rehabilitation of two cases with mandibular defects with an attachment-retained fixed-removable hybrid prosthesis. PMID:29042738
Partial double-layered patella in a nondysplasic adolescent.
García-Mata, Serafín; Hidalgo-Ovejero, Angel
2016-11-01
Double-layered patella (DLP) is a rare patella-formation abnormality reported in association with multiple epiphyseal dysplasia. DLP is one of the five types of bipartite patella, caused by a coronal septum that divides the patella into anterior and posterior segments. Although the double layer of bone has been reported as complete, it may also manifest as partial, as in our case. A 13-year-old male patient attended A&E after accidentally falling and sustaining a direct injury to his left knee, with pain in the anterior surface of the right patella. He was diagnosed with an incomplete vertical fracture of the left patella. An axial view radiography indicated an external partial DLP. No bone dysplasia was found. Computed tomographic scan and MRI showed partial DLP and bone marrow oedema because of the injury in the femoral condyle, but no fracture. The reason for highlighting this type of patella abnormality is to present the case of a patient without bone dysplasia, either partial or incomplete, that has not been reported previously. We also wish to emphasize the importance of not confusing it with a fracture in standard radiographies.
STS-26 crew trains in JSC fixed-based (FB) shuttle mission simulator (SMS)
NASA Technical Reports Server (NTRS)
1987-01-01
STS-26 Discovery, Orbiter Vehicle (OV) 103, Commander Frederick H. Hauck (left) and Pilot Richard O. Covey train in JSC fixed-based (FB) shuttle mission simulator (SMS) located in the Mission Simulation and Training Facility Bldg 5. On FB-SMS flight deck, Hauck and Covey man their respective stations. Mission Specialist (MS) David C. Hilmers is partially visible in the foreground. A simulation for their anticipated June 1988 flight began 10-20-87.
High-resolution MR imaging for dental impressions: a feasibility study.
Boldt, Julian; Rottner, Kurt; Schmitter, Marc; Hopfgartner, Andreas; Jakob, Peter; Richter, Ernst-Jürgen; Tymofiyeva, Olga
2018-04-01
Magnetic resonance imaging is an emerging technology in dental medicine. While low-resolution MRI has especially provided means to examine the temporomandibular joint due to its anatomic inaccessibility, it was the goal of this study to assess whether high-resolution MRI is capable of delivering a dataset sufficiently precise enough to serve as digital impression of human teeth. An informed and consenting patient in need of dental restoration with fixed partial dentures was chosen as subject. Two prepared teeth were measured using MRI and the dataset subjected to mathematical processing before Fourier transformation. After reconstruction, a 3D file was generated which was fed into an existing industry standard CAD/CAM process. A framework for a fixed dental prosthesis was digitally modeled and manufactured by laser-sintering. The fit in situ was found to be acceptable by current clinical standards, which allowed permanent placement of the fixed prosthesis. Using a clinical whole-body MR scanner with the addition of custom add-on hardware, contrast enhancement, and data post-processing, resolution and signal-to-noise ratio were sufficiently achieved to allow fabrication of a dental restoration in an acquisition time comparable to the setting time of common dental impression materials. Furthermore, the measurement was well tolerated. The herein described method can be regarded as proof of principle that MRI is a promising option for digital impressions when fixed partial dentures are required.
Middleton, S W F; Schranz, P J; Mandalia, V I; Toms, A D
2018-05-03
The surgical management of isolated medial compartment degenerative disease of the knee causes debate. Unicompartmental arthroplasty options include fixed and mobile bearing implant designs with fixed bearing becoming increasingly popular. We present the largest cohort of a fixed bearing single radius design, Stryker Triathlon Partial Knee Replacement (PKR). We prospectively collected demographic data and patient reported outcome measures (PROMs) on our cohort of PKR implants since its adoption in our unit, 2009 until March 2015. A total of 129 implants in 115 patients with a mean follow-up of 5.5 years (2.5 to 8.5 years) were included. There were 11 revisions at an average of 1.7 years (0.6-4.1 years), two for infection, two for mal-alignment, five for progression of disease and two for loosening. The survivorship of the implants at five years is 90%. The PKR provides good survivorship at five years and PROM scores that are equal to the largest and most popular comparable implants. There is an associated learning curve with this implant, as there is with all systems and this is reflected in our results. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.
Viral Oncolytic Therapeutics for Neoplastic Meningitis
2013-07-01
infusion method, we worked with our animal vendor, Charles River Laboratories (CRL), to adopt their intrathecal catheterization service for our...traslocation of the injected material in CSF, we attempted to correlate the parameters of lumbar bolus in intrathecally catheterized rats with those in non...explained by either partial blockage of the spinal CSF compartment in catheterized animals or by variable posterior hydrodynamic compliance (or both) and
An overlay partial denture to restore worn mandibular anterior teeth.
Samant, Asha; DeSciscio, Peter
2014-01-01
Restoring worn anterior mandibular teeth is a challenge, especially when teeth are small, esthetics are a concern, the long-term prognosis is questionable, and/or patient finances are an issue. This article describes an alternate treatment for a patient with a collapsed bite, missing posterior mandibular teeth, an ill-fitting complete maxillary denture with poor esthetics, and irregular, worn mandibular anterior teeth.
Schmitt-Wagner, Dirk; Brune, Andreas
1999-01-01
It has been shown that the coexistence of methanogenesis and reductive acetogenesis in the hindgut of the wood-feeding termite Reticulitermes flavipes is based largely on the radial distribution of the respective microbial populations and relatively high hydrogen partial pressures in the gut lumen. Using Clark-type microelectrodes, we showed that the situation in Cubitermes orthognathus and other soil-feeding members of the subfamily Termitinae is different and much more complex. All major compartments of agarose-embedded hindguts were anoxic at the gut center, and high H2 partial pressures (1 to 10 kPa) in the alkaline anterior region rendered the mixed segment and the third proctodeal segment (P3) significant sources of H2. Posterior to the P3 segment, however, H2 concentrations were generally below the detection limit (<100 Pa). All hindgut compartments turned into efficient hydrogen sinks when external H2 was supplied, but methane was formed mainly in the P3/4a and P4b compartments, and in the latter only when H2 or formate was added. Addition of H2 to the gas headspace stimulated CH4 emission of living termites, indicating that endogenous H2 production limits methanogenesis also in vivo. At the low H2 partial pressures in the posterior hindgut, methanogens would most likely outcompete homoacetogens for this electron donor. This might explain the apparent predominance of methanogenesis over reductive acetogenesis in the hindgut of soil-feeding termites, although the presence of homoacetogens in the anterior, highly alkaline region cannot yet be excluded. In addition, the direct contact of anterior and posterior hindgut compartments in situ permits a cross-epithelial transfer of H2 or formate, which would not only fuel methanogenesis in these compartments, but would also create favorable microniches for reductive acetogenesis. In situ rates and spatial distribution of H2-dependent acetogenic activities are addressed in a companion paper (A. Tholen and A. Brune, Appl. Environ. Microbiol. 65:4497–4505, 1999). PMID:10508080
Duplex System with Ectopic Ureter Opens into the Posterior Urethra: Case Report.
Milicevic, Snjezana; Bijelic, Radojka; Krivokuca, Vladimir; Jakovljevic, Branislava
2018-04-01
Duplicated ureter or Duplex Collecting System is a congenital condition in which the ureteric bud, the embryological origin of the ureter, arises twice, resulting in two ureters draining a single kidney. This congenital anomaly is rare, and even rarer when the duplex system with ectopic ureter is present. This type of congenital anomaly is even more rarely diagnosed and surgically treated in adulthood. This case report presents a case of a 32-year-old male, who had a duplex collecting system with two ureters on the left side. Ectopic ureter, draining the upper pole of the left kidney, opened into the posterior urethra. In our patient, taking into account the clinical perspective, the renal tissue damaging of the upper pole which was not functional, partial nephrectomy and ureterectomy was successfully performed.
Determining X-ray source intensity and confidence bounds in crowded fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Primini, F. A.; Kashyap, V. L., E-mail: fap@head.cfa.harvard.edu
We present a rigorous description of the general problem of aperture photometry in high-energy astrophysics photon-count images, in which the statistical noise model is Poisson, not Gaussian. We compute the full posterior probability density function for the expected source intensity for various cases of interest, including the important cases in which both source and background apertures contain contributions from the source, and when multiple source apertures partially overlap. A Bayesian approach offers the advantages of allowing one to (1) include explicit prior information on source intensities, (2) propagate posterior distributions as priors for future observations, and (3) use Poisson likelihoods,more » making the treatment valid in the low-counts regime. Elements of this approach have been implemented in the Chandra Source Catalog.« less
Haldipur, Parthiv; Dang, Derek; Aldinger, Kimberly A; Janson, Olivia K; Guimiot, Fabien; Adle-Biasette, Homa; Dobyns, William B; Siebert, Joseph R; Russo, Rosa; Millen, Kathleen J
2017-01-01
FOXC1 loss contributes to Dandy-Walker malformation (DWM), a common human cerebellar malformation. Previously, we found that complete Foxc1 loss leads to aberrations in proliferation, neuronal differentiation and migration in the embryonic mouse cerebellum (Haldipur et al., 2014). We now demonstrate that hypomorphic Foxc1 mutant mice have granule and Purkinje cell abnormalities causing subsequent disruptions in postnatal cerebellar foliation and lamination. Particularly striking is the presence of a partially formed posterior lobule which echoes the posterior vermis DW 'tail sign' observed in human imaging studies. Lineage tracing experiments in Foxc1 mutant mouse cerebella indicate that aberrant migration of granule cell progenitors destined to form the posterior-most lobule causes this unique phenotype. Analyses of rare human del chr 6p25 fetal cerebella demonstrate extensive phenotypic overlap with our Foxc1 mutant mouse models, validating our DWM models and demonstrating that many key mechanisms controlling cerebellar development are likely conserved between mouse and human. DOI: http://dx.doi.org/10.7554/eLife.20898.001 PMID:28092268
Kato, Haruaki; Kobayashi, Shinya; Kawakami, Masako; Inoue, Hiroo; Iijima, Kazuyoshi; Nishizawa, Osamu
2004-10-01
Repair of a posterior urethral disruption associated with a pelvic fracture is a challenge for urologic surgeons. Here, we provide surgical and strategic tips to facilitate the delayed surgical repair of urethral distraction defects. Nine patients each with a traumatic posterior urethral distraction defect underwent delayed transperineal or transperineoabdominal bulboprostatic anastomosis. Four patients had previously undergone multiple procedures. Seven patients regained satisfactory urination without incontinence, although one other patient is suffering from incontinence. In one patient, urethral disruption occurred again after removal of the urethral catheter, and he is being managed by suprapubic catheter. In our experience, the key to success is to perform a true bulboprostatic mucosa-to-mucosa anastomosis without tension. For this purpose, a transperineoabdominal approach is of particular importance when the healthy mucosa of the prostatic apex cannot be revealed through a perineal approach due to dense fibrous scar or fractured bone. A partial pubectomy may be necessary according to the situation. By the transperineoabdominal approach, the scar tissue can be bypassed through a broad sub-pubic-arch tunnel, and a reliable anastomosis achieved.
Fixed and mobile-bearing total ankle prostheses: Effect on tibial bone strain.
Terrier, Alexandre; Fernandes, Caroline Sieger; Guillemin, Maïka; Crevoisier, Xavier
2017-10-01
Total ankle replacement is associated to a high revision rate. To improve implant survival, the potential advantage of prostheses with fixed bearing compared to mobile bearing is unclear. The objective of this study was to test the hypothesis that fixed and mobile bearing prostheses are associated with different biomechanical quantities typically associated to implant failure. With a validated finite element model, we compared three cases: a prosthesis with a fixed bearing, a prosthesis with a mobile bearing in a centered position, and a prosthesis with mobile bearing in an eccentric position. Both prostheses were obtained from the same manufacturer. They were tested on seven tibias with maximum axial compression force during walking. We tested the hypothesis that there was a difference of bone strain, bone-implant interfacial stress, and bone support between the three cases. We also evaluated, for the three cases, the correlations between bone support, bone strain and bone-implant interfacial stress. There were no statistically significant differences between the three cases. Overall, bone support was mainly trabecular, and less effective in the posterior side. Bone strain and bone-implant interfacial stress were strongly correlated to bone support. Even if slight differences are observed between fixed and mobile bearing, it is not enough to put forward the superiority of one of these implants regarding their reaction to axial compression. When associated to the published clinical results, our study provides no argument to warn surgeons against the use of two-components fixed bearing implants. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kop, Alan M; Swarts, Eric
2007-06-01
Routine qualitative observations of more than 850 polyethylene fixed and mobile bearings at our institution have noted minimal wear of mobile bearings. The APG mobile bearing is the most recent design variant of the LCS knee, allows multi-directional movement at the tibiofemoral articulation, and is posterior cruciate sparing. Even though it is difficult to perform, quantitative wear measurement is important in determining the likely longevity of new arthroplasty devices, and is especially relevant because of increasing numbers of new mobile bearing designs. We analyzed 10 retrieved APG and 7 retrieved RP tibial bearings (De Puy) with a mean implantation period of 33 (9-70) months. We used coordinate-measuring techniques to quantitatively determine linear penetration, and optical and scanning electron microscopy to assess wear mechanisms qualitatively. The mean total volume loss (superior and inferior articulations) of the APG and RP designs was 85 mm((3))/year and 77 mm((3))/year, respectively. Burnishing was the predominant wear mechanism, and to a lesser extent scratching, abrasion and pitting. Multidirectional scratching and abrasion were noted on the APG inserts inferiorly, whereas there was circumferential scratching on the RP inserts. Our short-term results for the APG and RP mobile bearing designs are similar and compare more than favorably with reported values for fixed-bearing designs. However, increased backside wear due to multidirectional movement may predispose the APG design to greater wear in the long term.
A Bayesian Surrogate for Regional Skew in Flood Frequency Analysis
NASA Astrophysics Data System (ADS)
Kuczera, George
1983-06-01
The problem of how to best utilize site and regional flood data to infer the shape parameter of a flood distribution is considered. One approach to this problem is given in Bulletin 17B of the U.S. Water Resources Council (1981) for the log-Pearson distribution. Here a lesser known distribution is considered, namely, the power normal which fits flood data as well as the log-Pearson and has a shape parameter denoted by λ derived from a Box-Cox power transformation. The problem of regionalizing λ is considered from an empirical Bayes perspective where site and regional flood data are used to infer λ. The distortive effects of spatial correlation and heterogeneity of site sampling variance of λ are explicitly studied with spatial correlation being found to be of secondary importance. The end product of this analysis is the posterior distribution of the power normal parameters expressing, in probabilistic terms, what is known about the parameters given site flood data and regional information on λ. This distribution can be used to provide the designer with several types of information. The posterior distribution of the T-year flood is derived. The effect of nonlinearity in λ on inference is illustrated. Because uncertainty in λ is explicitly allowed for, the understatement in confidence limits due to fixing λ (analogous to fixing log skew) is avoided. Finally, it is shown how to obtain the marginal flood distribution which can be used to select a design flood with specified exceedance probability.
Mangnall, Louise A R; Dietrich, Thomas; Scholey, John M
2013-01-01
Objective: To determine patient experience of pain during treatment with fixed orthodontic appliances, expectations of pain during debond and whether biting on a soft acrylic wafer during debond decreases pain experience. Design: Multicentre randomized controlled trial. Setting: Three UK hospital based orthodontic departments: Mid-Staffordshire NHS Foundation Trust, Birmingham Dental Hospital and University Hospital of North Staffordshire. Materials and methods: Ninety patients were randomly allocated to either the control (n = 45) or wafer group (n = 45). A visual analogue scale-based questionnaire was completed pre-debond to determine pain experience during treatment and expectations of pain during debond. The appliances were debonded and those in the wafer group bit on a soft acrylic wafer. A second questionnaire was completed post-debond to assess the pain experienced. Results: Biting on an acrylic wafer significantly reduced the pain experienced when debonding the posterior teeth (P≤0·05). Thirty-nine per cent found the lower anterior teeth the most painful. The expected pain was significantly greater than that actually experienced (P≤0·0001). Greater pain during treatment correlated with increased expectations and increased actually experienced pain (P≤0·0001). Conclusions: Biting on a soft acrylic wafer during debond of the posterior teeth reduces the pain experienced. The lower anterior teeth are the most painful. The pain expected is significantly greater than actually experienced. Patients who had greater pain during treatment expected and experienced greater pain at debond. PMID:24009318
Long-term effects of placing one or two cages in instrumented posterior lumbar interbody fusion.
Zhang, Mingzheng; Pu, Fang; Xu, Liqiang; Zhang, Linlin; Yao, Jie; Li, Deyu; Wang, Yu; Fan, Yubo
2016-06-01
Posterior lumbar interbody fusion (PLIF) is an established surgical procedure for spine stabilization after the removal of an intervertebral disc. Researches have shown that inserting a single oblique cage has a similar immediate effect to coupled cages, and it has been proposed that single-cage PLIF is a useful alternative to traditional two-cage PLIF. However, it is not clear whether placing one or two cages represents the best choice for long-term fusion. The aim of this study is to examine how cage placement affects bone remodeling after PLIF surgery, and how this consequently impacts the long-term fusion process. A finite element model of a L3-L4 lumbar spine with PLIF was developed. The spinal segment was modeled with a partial laminectomy and a discectomy with partial facetectomy, and implanted with posterior pedicle screws. Two models were analyzed, one with coupled parallel cages and one with a single oblique cage. Adaptive bone remodeling was simulated according to Huiskes' criterion. The results showed that in the initial state prior to any bone remodeling, cage stress, cage subsidence and cage dislodgement in the single cage model were all greater than in the coupled cage model. In the final state after significant bone remodeling had taken place, these parameters had decreased in both models and the differences between the two models were reduced. Also, the single cage model demonstrated superior bone development in the bone graft when placed under a constant 400 N axial compressive load. Based on the long-term results, instrumented PLIF with a single cage could also be encouraged in clinical practice.
Cluver, Catherine Anne; Hofmeyr, G Justus
2015-06-01
The purpose of this study was to report on all cases in which posterior axilla sling traction (PAST) has been used to deliver cases of intractable shoulder dystocia and to describe a new method of shoulder rotation with the sling. A record of all published and known cases was collected that included information on preliminary obstetric techniques that were used and how the PAST technique was performed. Maternal outcomes that included maternal injury and length of hospital stay and fetal outcomes, which included birthweight, Apgar scores, nerve injuries, fractures, hospital stay, and outcome, were documented. We have recorded 19 cases where PAST has been used. In 5 cases, the babies had died in utero. Ten were assisted deliveries. PAST was successful in 18 cases. In one case, it was partially successful because it enabled delivery of the posterior shoulder with digital axillary traction. The most commonly used material was suction tubing. Once the posterior shoulder was delivered, the shoulder dystocia was resolved in all cases. Time from insertion to delivery was <3 minutes when recorded. The birthweights of the infants varied from 3200-4800 g. Posterior arm humerus fractures occurred in 3 cases. There was one case of a permanent Erb's palsy and 4 cases of transient Erb's palsies. None were of the posterior arm. During this review, we found that, when direct delivery of the posterior shoulder was difficult because of very severe impaction, the sling could be used to rotate the shoulders easily through 180 degrees assisted by counter pressure on the back of the anterior shoulder. This new method was used in 5 cases and may reduce fetal trauma further during difficult shoulder delivery. This review confirms that PAST can be a lifesaving technique when all another techniques for shoulder dystocia fail. Advantages are that it is easy to use (even by someone who has not seen it used previously), that the sling material is readily available, and that it is inserted quickly with 2 fingers. This is the first report of its use to rotate the posterior shoulder to the anterior position for delivery. Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ju, N; Chen, C; Gans, S
Purpose: A fixed-beam room could be underutilized in a multi-room proton center. We investigated the use of proton pencil beam scanning (PBS) on a fixed-beam as an alternative for posterior fossa tumor bed (PF-TB) boost treatments which were usually treating on a gantry with uniform scanning. Methods: Five patients were treated with craniospinal irradiation (CSI, 23.4 or 36.0 Gy(RBE)) followed by a PF-TB boost to 54 Gy(RBE) with proton beams. Three PF-TB boost plans were generated for each patient: (1) a uniform scanning (US) gantry plan with 4–7 posterior fields shaped with apertures and compensators (2) a PBS plan usingmore » bi-lateral and vertex fields with a 3-mm planning organ-at-risk volume (PRV) expansion around the brainstem and (3) PBS fields using same beam arrangement but replacing the PRV with robust optimization considering a 3-mm setup uncertainty. Results: A concave 54-Gy(RBE) isodose line surrounding the brainstem could be achieved using all three techniques. The mean V95% of the PTV was 99.7% (range: 97.6% to 100%) while the V100% of the PTV ranged from 56.3% to 93.1% depending on the involvement of the brainstem with the PTV. The mean doses received by 0.05 cm{sup 3} of the brainstem were effectively identical: 54.0 Gy(RBE), 53.4 Gy(RBE) and 53.3 Gy(RBE) for US, PBS optimized with PRV, and PBS optimized with robustness plans respectively. The cochlea mean dose increased by 23% of the prescribed boost dose in average from the bi-lateral fields used in the PBS plan. Planning time for the PBS plan with PRV was 5–10 times less than the US plan and the robustly optimized PBS plan. Conclusion: We have demonstrated that a fixed-beam with PBS can deliver a dose distribution comparable to a gantry plan using uniform scanning. Planning time can be reduced substantially using a PRV around the brainstem instead of robust optimization.« less
Fracture analysis of randomized implant-supported fixed dental prostheses
Esquivel-Upshaw, Josephine F.; Mehler, Alex; Clark, Arthur E.; Neal, Dan; Anusavice, Kenneth J.
2014-01-01
Objective Fractures of posterior fixed dental all-ceramic prostheses can be caused by one or more factors including prosthesis design, flaw distribution, direction and magnitude of occlusal loading, and nature of supporting infrastructure (tooth root/implant), and presence of adjacent teeth. This clinical study of implant-supported, all-ceramic fixed dental prostheses, determined the effects of (1) presence of a tooth distal to the most distal retainer; (2) prosthesis loading either along the non-load bearing or load bearing areas; (3) presence of excursive contacts or maximum intercuspation contacts in the prosthesis; and (4) magnitude of bite force on the occurrence of veneer ceramic fracture. Methods 89 implant-supported FDPs were randomized as either a three-unit posterior metal-ceramic (Au-Pd-Ag alloy and InLine POM, Ivoclar, Vivadent) FDP or a ceramic-ceramic (ZirCAD and ZirPress, Ivoclar, Vivadent) FDP. Two implants (Osseospeed, Dentsply) and custom abutments (Atlantis, Dentsply) supported these FDPs, which were cemented with resin cement (RelyX Universal Cement). Baseline photographs were made with markings of teeth from maximum intercuspation (MI) and excursive function. Patients were recalled at 6 months and 1 to 3 years. Fractures were observed, their locations recorded, and images compared with baseline photographs of occlusal contacts. Conclusion No significant relationship exists between the occurrence of fracture and: (1) the magnitude of bite force; (2) a tooth distal to the most distal retainer; and (3) contacts in load-bearing or non-load-bearing areas. However, there was a significantly higher likelihood of fracture in areas with MI contacts only. Clinical Significance This clinical study demonstrates that there is a need to evaluate occlusion differently with implant-supported prostheses than with natural tooth supported prostheses because of the absence of a periodontal ligament. Implant supported prostheses should have minimal occlusion and lighter contacts than ones supported by natural dentition. PMID:25016139
Umeoka, Shuichi C; Lüders, Hans O; Turnbull, John P; Koubeissi, Mohamad Z; Maciunas, Robert J
2012-03-01
The goal in this study was to assess the role of longitudinal hippocampal circuits in the generation of interictal and ictal activity in temporal lobe epilepsy (TLE) and to evaluate the effects of multiple hippocampal transections (MHT). In 6 patients with TLE, the authors evaluated the synchrony of hippocampal interictal and ictal epileptiform discharges by using a cross-correlation analysis, and the effect of MHT on hippocampal interictal spikes was studied. Five of the 6 patients were studied with depth electrodes, and epilepsy surgery was performed in 4 patients (anterior temporal lobectomy in 1 and MHT in 3). Four hundred eighty-two (95.1%) of 507 hippocampal spikes showed an anterior-to-posterior propagation within the hippocampus, with a fixed peak-to-peak interval. During seizures, a significant increase of synchronization between different hippocampal regions and between the hippocampus and the ipsilateral anterior parahippocampal gyrus was observed in all seizures. An ictal increase in synchronization between the hippocampus and ipsilateral amygdala was seen in only 24.1% of the seizures. No changes in synchronization were noticed during seizures between the hippocampi and the amygdala on either side. The structure leading the epileptic seizures varied over time during a given seizure and also from one seizure to another. Spike analysis during MHT demonstrated that there were two spike populations that reacted differently to this procedure--namely, 1) spikes that showed maximum amplitude at the head of the hippocampus (type H); and 2) spikes that showed the highest amplitude at the hippocampal body (type B). A striking decrease in amplitude and frequency of type B spikes was noticed in all 3 patients after transections at the head or anterior portion of the hippocampal body. Type H spikes were seen in 2 cases and did not change in amplitude and frequency throughout MHT. Type B spikes showed constantly high cross-correlation values in different derivations and a relatively fixed peak-to-peak interval before MHT. This fixed interpeak delay disappeared after the first transection, although high cross-correlation values persisted unchanged. All patients who underwent MHT remained seizure free for more than 2 years. These data suggest that synchronized discharges involving the complete anterior-posterior axis of the hippocampal/parahippocampal (H/P) formation underlie the spread of epileptiform discharges outside the H/P structures and, therefore, for the generation of epileptic seizures originating in the H/P structures. This conclusion is supported by the following observations. 1) Hippocampal spikes are consistently synchronized in the whole hippocampal structures, with a fixed delay between the different hippocampal areas. 2) One or two transections between the head and body of the hippocampal formation are sufficient to abolish hippocampal spikes that are synchronized along the anterior-posterior axis of the hippocampus. 3) Treatment with MHT leads to seizure freedom in patients with H/P epilepsy.
[Fiber-reinforced composite in fixed prosthodontics].
Pilo, R; Abu Rass, Z; Shmidt, A
2010-07-01
Fiber reinforced composite (FRC) is composed of resin matrix and fibers filler. Common types of fibers: polyethylene, carbon and glass. Fibers can be continuous and aligned, discontinuous and aligned, discontinuous and randomly oriented. The architecture of the fibers is unidirectional, woven or braided. The two main types are: dry fibers or impregnated. Inclusion of fibers to resin composite increased its average flexural strength in 100-200 MPa. FRC can be utilized by the dentist in direct approach (splinting, temporary winged bridge) or indirect approach (laboratory made fixed partial denture). Laboratory fixed partial denture (FPD) is made from FRC substructure and Hybrid/Microfill particulate composite veneer. Main indications: interim temporary FPD or FPD in cases of questionable abutment teeth, in aesthetic cases where All Ceram FPD is not feasible. Retention is attained by adhesive cementation to minimally prepared teeth or to conventionally prepared teeth; other options are inlay-onlay bridges or hybrid bridges. Contraindications are: poor hygiene, inability to control humidity, parafunction habits, and more than two pontics. Survival rate of FRC FPD over 5 years is 75%, lower compared to porcelain fused to metal FPD which is 95%. Main reasons for failure are: fracture of framework and delamination of the veneer. Part of the failures is repairable.
Design of Complete Dentures by Adopting CAD Developed for Fixed Prostheses.
Li, Yanfeng; Han, Weili; Cao, Jing; Iv, Yuan; Zhang, Yue; Han, Yishi; Shen, Yi; Ma, Zheng; Liu, Huanyue
2018-02-01
The demand for complete dentures is expected to increase worldwide, but complete dentures are mainly designed and fabricated manually involving a broad series of clinical and laboratory procedures. Therefore, the quality of complete dentures largely depends on the skills of the dentist and technician, leading to difficulty in quality control. Computer-aided design and manufacturing (CAD/CAM) has been used to design and fabricate various dental restorations including dental inlays, veneers, crowns, partial crowns, and fixed partial dentures (FPDs). It has been envisioned that the application of CAD/CAM technology could reduce intensive clinical/laboratory work for the fabrication of complete dentures; however, CAD/CAM is seldom used to fabricate complete dentures due to the lack of suitable CAD software to design virtual complete dentures although the CAM techniques are in a much advanced stage. Here we report the successful design of virtual complete dentures using CAD software of 3Shape Dental System 2012, which was developed for designing fixed prostheses instead of complete dentures. Our results demonstrated that complete dentures could be successfully designed by the combination of two modeling processes, single coping and full anatomical FPD, available in the 3Shape Dental System 2012. © 2016 by the American College of Prosthodontists.
Patel, Mit B; Bencharit, Sompop
2009-01-01
Treatment options for patients with severe attrition resulting in reduced occlusal vertical dimension are often limited to fixed prosthesis to reestablish proper occlusal vertical dimension and functional occlusion. In some cases such as when there are limited finances, minimal esthetic concerns, and medical considerations fixed prosthesis may not be the ideal treatment option. Overlay removable partial dentures (ORPDs) can be used as a provisional or interim prosthesis as well as permanent prosthesis in these cases. While ORPDs can provide a reversible and relatively inexpensive treatment for patients with a significantly compromised dental status, there is not much scientific evidence in the literature on ORPDs. Most studies published on ORPDs to date are primarily reviews and clinical reports. In this article, literatures on ORPDs are summarized and a patient treated with interim and permanent ORPDs is presented. This article reviews previously published literatures on the use of ORPDs. Indications, advantages and disadvantages are discussed. Treatment protocol with an example of the prosthodontic treatment of a patient with severely worn dentition with an interim ORPD and later a permanent ORPD are discussed in details. PMID:19915723
The role of a small posterior malleolar fragment in trimalleolar fractures: a biomechanical study.
Evers, J; Fischer, M; Zderic, I; Wähnert, D; Richards, R G; Gueorguiev, B; Raschke, M J; Ochman, S
2018-01-01
The aim of this study was to investigate the effect of a posterior malleolar fragment (PMF), with < 25% ankle joint surface, on pressure distribution and joint-stability. There is still little scientific evidence available to advise on the size of PMF, which is essential to provide treatment. To date, studies show inconsistent results and recommendations for surgical treatment date from 1940. A total of 12 cadaveric ankles were assigned to two study groups. A trimalleolar fracture was created, followed by open reduction and internal fixation. PMF was fixed in Group I, but not in Group II. Intra-articular pressure was measured and cyclic loading was performed. Contact area decreased following each fracture, while anatomical fixation restored it nearly to its intact level. Contact pressure decreased significantly with fixation of the PMF. In plantarflexion, the centre of force shifted significantly posteriorly in Group II and anteriorly in Group I. Load to failure testing showed no difference between the groups. Surgical reduction of a small PMF with less than 25% ankle joint surface improves pressure distribution but does not affect ankle joint stability. Cite this article: Bone Joint J 2018;100-B:95-100. ©2018 The British Editorial Society of Bone & Joint Surgery.
Kim, Young-Mo; Rhee, Kwang-Jin; Lee, June-Kyu; Hwang, Deuk-Soo; Yang, Jun-Young; Kim, Sung-Jae
2006-07-01
We developed an effective arthroscopic pullout technique for repairing complete radial tears of the tibial attachment site of the medial meniscus posterior horn (MMPH). In our technique, the torn meniscus is reattached to the tibial plateau immediately medial or anteromedial to the posterior cruciate ligament (PCL) using two No. 2 Ethibond sutures (Ethicon, Somerville, NJ). After a complete radial tear of the tibial attachment site of the MMPH and its reparability were confirmed, using a Caspari suture loaded with a suture shuttle, one No. 2 Ethibond suture is placed through the meniscus, through the red-red zone, 3 to 5 mm medial to the torn edge of the MMPH, and the other is passed through the meniscocapsular junction 3 to 5 mm medial to the torn edge of the meniscus. Then, a tibial tunnel, 5-mm in diameter, is made from the anteromedial aspect of the proximal tibia to the previously prepared tibial plateau, immediately medial or anteromedial to the PCL, and the two No. 2 Ethibond sutures are pulled out through the tibial tunnel and then fixed to the proximal tibia using a 3.5-mm cortical screw and washer. Firm reattachment of the torn meniscus was confirmed arthroscopically.
Ferrari, Ulisse
2016-08-01
Maximum entropy models provide the least constrained probability distributions that reproduce statistical properties of experimental datasets. In this work we characterize the learning dynamics that maximizes the log-likelihood in the case of large but finite datasets. We first show how the steepest descent dynamics is not optimal as it is slowed down by the inhomogeneous curvature of the model parameters' space. We then provide a way for rectifying this space which relies only on dataset properties and does not require large computational efforts. We conclude by solving the long-time limit of the parameters' dynamics including the randomness generated by the systematic use of Gibbs sampling. In this stochastic framework, rather than converging to a fixed point, the dynamics reaches a stationary distribution, which for the rectified dynamics reproduces the posterior distribution of the parameters. We sum up all these insights in a "rectified" data-driven algorithm that is fast and by sampling from the parameters' posterior avoids both under- and overfitting along all the directions of the parameters' space. Through the learning of pairwise Ising models from the recording of a large population of retina neurons, we show how our algorithm outperforms the steepest descent method.
Finite element analysis of an implant-assisted removable partial denture.
Shahmiri, Reza; Aarts, John M; Bennani, Vincent; Atieh, Momen A; Swain, Michael V
2013-10-01
This study analyzes the effects of loading a Kennedy class I implant-assisted removable partial denture (IARPD) using finite element analysis (FEA). Standard RPDs are not originally designed to accommodate a posterior implant load point. The null hypothesis is that the introduction of posteriorly placed implants into an RPD has no effect on the load distribution. A Faro Arm scan was used to extract the geometrical data of a human partially edentulous mandible. A standard plus regular neck (4.8 × 12 mm) Straumann® implant and titanium matrix, tooth roots, and periodontal ligaments were modeled using a combination of reverse engineering in Rapidform XOR2 and solid modeling in Solidworks 2008 FEA program. The model incorporated an RPD and was loaded with a bilateral force of 120 N. ANSYS Workbench 11.0 was used to analyze deformation in the IARPD and elastic strain in the metal framework. FEA identified that the metal framework developed high strain patterns on the major and minor connectors, and the acrylic was subjected to deformation, which could lead to acrylic fractures. The ideal position of the neutral axis was calculated to be 0.75 mm above the ridge. A potentially destructive mismatch of strain distribution was identified between the acrylic and metal framework, which could be a factor in the failure of the acrylic. The metal framework showed high strain patterns on the major and minor connectors around the teeth, while the implant components transferred the load directly to the acrylic. © 2013 by the American College of Prosthodontists.
Thankamony, Priyakumari; Sivarajan, Venugopal; Mony, Rari P; Muraleedharan, Venugopal
2016-01-01
Congenital anomalies may be associated with Wilms tumor either as isolated anomalies or as part of a congenital malformation syndrome. Nephroblastoma occurring in association with polycystic kidneys is very rare. The optimal surgical management of nephroblastoma in the setting of polycystic kidneys is not defined because of the rarity of this presentation. PHACE syndrome includes posterior fossa anomalies, hemangioma, arterial lesions, cardiac abnormalities/coarctation of aorta, and eye abnormalities. We report a 17-month-old baby with bilateral polycystic kidneys and PHACE syndrome who developed nephroblastoma in the right polycystic kidney which was treated successfully with nephron-sparing partial nephrectomy and chemotherapy.
Fixed or removable function appliances for Class II malocclusions.
Madurantakam, Parthasarathy
2016-06-01
Data sourcesEmbase, Cochrane Central Register of Controlled Trials, Medline (Pubmed), Web of Science, Google Scholar, Scopus, LILACS database and bibliographies of clinical trials encountered during search. There was no restriction on language or date during search.Study selectionRandomised Controlled Trials (RCTs) and Controlled Clinical Trials (CCT) in patients with Class II malocclusions that compared at least one fixed functional appliance with at least one removable functional appliance (RFA) in children below 16 years of age. Primary outcomes were clinical and lateral cephalometric measurements and the duration of treatment. Secondary outcomes included patient experiences of treatment, quality of life measures and harms arising during treatment as well as costs of both treatments.Data extraction and synthesisThe titles and abstracts of all studies identified through the search were assessed independently and in duplicate by two review authors. Disagreements about included studies were resolved through discussion with the third author. Heterogeneity was assessed using customised forms and risk of bias using a Cochrane Collaboration tool. A meta-analysis was planned for studies at low risk of bias with similar comparisons reporting the same outcome.ResultsTwo RCTs and two CCTs that met the inclusion/exclusion criteria were included in the final analysis. Risk of bias assessment indicated three trials were at high risk while one was unclear. Consequently, the included trials were deemed to be inappropriate for meta-analysis (MA).Two studies with 282 participants evaluated Twin Block with fixed Herbst appliance and reported significant improvements in anterior-posterior skeletal discrepancy, mandibular length and reduction of overjet with both appliances. While one study reported significantly shorter treatment duration in Herbst appliance, the other study did not find any difference. Herbst appliance had better compliance, less dropouts but more emergency visits.One trial that compared activator appliance with Twin Force Bite Corrector found significantly shorter time with the fixed appliance. However, effective length and sagittal positioning of the mandible was not different between the groups.One trial comparing activator with Forsus FRZ reported enhanced mandibular growth and restrained maxillary growth with both the appliances. While activator appliance was associated with increased posterior facial height, Forsus significantly rotated the occlusal plane.ConclusionsLimited available evidence indicates that both fixed and removable functional appliances are effective in reducing overjet in growing children. However, there is insufficient evidence to differentiate between the two types with respect to biological (skeletal and dental) effects or patient experiences.
Eguizabal, Johnny; Tufaga, Michael; Scheer, Justin K; Ames, Christopher; Lotz, Jeffrey C; Buckley, Jenni M
2010-05-07
In vitro multi-axial bending testing using pure moment loading conditions has become the standard in evaluating the effects of different types of surgical intervention on spinal kinematics. Simple, cable-driven experimental set-ups have been widely adopted because they require little infrastructure. Traditionally, "fixed ring" cable-driven experimental designs have been used; however, there have been concerns with the validity of this set-up in applying pure moment loading. This study involved directly comparing the loading state induced by a traditional "fixed ring" apparatus versus a novel "sliding ring" approach. Flexion-extension bending was performed on an artificial spine model and a single cadaveric test specimen, and the applied loading conditions to the specimen were measured with an in-line multiaxial load cell. The results showed that the fixed ring system applies flexion-extension moments that are 50-60% less than the intended values. This design also imposes non-trivial anterior-posterior shear forces, and non-uniform loading conditions were induced along the length of the specimen. The results of this study indicate that fixed ring systems have the potential to deviate from a pure moment loading state and that our novel sliding ring modification corrects this error in the original test design. This suggests that the proposed sliding ring design should be used for future in vitro spine biomechanics studies involving a cable-driven pure moment apparatus. Copyright 2010 Elsevier Ltd. All rights reserved.
Minoda, Yukihide; Ikebuchi, Mitsuhiko; Mizokawa, Shigekazu; Ohta, Yoichi; Nakamura, Hiroaki
2016-11-01
Proper anteroposterior (AP) joint displacement is an important indicator of good clinical outcome following total knee arthroplasty (TKA). We hypothesized that a newly introduced mobile-bearing posterior stabilized (PS) prosthesis reduces the AP joint displacement. The aim of this study is to compare the AP joint displacement between a newly introduced mobile-bearing PS TKA in one knee and a conventional fixed-bearing PS TKA in other knee. 82 knees in 41 patients who had bilateral TKAs were investigated. All the patients received a conventional fixed-bearing PS prosthesis in one knee and a highly congruent mobile-bearing PS prosthesis in the other knee. AP joint displacement was measured using the KT-2000 arthrometer, at 30° and 75° in flexion, at average of 3.3 years after the operation. AP joint displacements at 30° in flexion were 6 ± 3 mm in the knees with the mobile-bearing PS prosthesis and 9 ± 4 mm in the knee with fixed-bearing PS prosthesis (p < 0.001). AP joint displacements at 75° in flexion were 4 ± 2 mm in the knees with the mobile-bearing PS prosthesis and 6 ± 3 mm in the knee with fixed-bearing PS prosthesis (p < 0.001). This study suggested that the design of the prosthesis can improve the AP joint stability in mid-flexion range.
Sanghi, Gaurav; Dogra, Mangat R; Das, Pranab; Vinekar, Anand; Gupta, Amod; Dutta, Saurabh
2009-10-01
To analyze the spectrum of aggressive posterior retinopathy of prematurity and outcome after laser treatment. This is a retrospective review of 81 eyes of 44 consecutive infants diagnosed to have aggressive posterior retinopathy of prematurity and treated between September 2005 and March 2007 from a large tertiary care center in North India. Qualitative variables were tested for statistical significance using the chi-square test and independent samples with the student's t-test. Mean birth weight and gestational age were 1,259.66 +/- 310.51 g (range, 660-2,000 g) and 29.75 +/- 2.35 weeks (range, 26-36 weeks), respectively. Twenty-one infants (47.72%) had a birth weight > 1,250 g. Thirty-three (40.74%) eyes had Zone 1, and 48 (59.26%) had posterior Zone 2 disease. All eyes underwent confluent laser photocoagulation at a mean postconceptional age of 34.58 +/- 2.19 weeks (range, 31-40.5 weeks). Mean follow-up was 12.8 months (range, 6-24 months). At the last follow-up visit, 55 (71.4%) of 77 eyes had a favorable outcome. Eighteen eyes (23.4%) had a localized (1-3 clock hours) partial peripheral tractional detachment (Stage 4a), which remained stable at last follow-up. Two eyes (2.6%) developed falciform fold involving the macular area, and 2 (2.6%) developed Stage 5 retinopathy of prematurity. Aggressive posterior retinopathy of prematurity is encountered not only in low birth weight infants, but also in heavier and more mature Asian Indian infants. Early, aggressive confluent laser photocoagulation is necessary to maximize outcomes in these eyes.
The Trapezius Muscle Flap: A Viable Alternative for Posterior Scalp and Neck Reconstruction.
Yang, Hee Jun; Lee, Dong Hun; Kim, Yang Woo; Lee, Sang Gu; Cheon, Young Woo
2016-11-01
The trapezius muscle flap is not usually the first reconstructive option for skin and soft tissue defects in the posterior neck and scalp due to surgeons' unfamiliarity with the surgical anatomy and developments in free tissue transfer techniques. The goals of this study were to describe the clinical use of trapezius flaps in posterior neck and scalp reconstruction, and to investigate the vascular anatomy of trapezius flaps in Asians in order to obtain information facilitating the safe design and elevation of flaps in which most of the muscle is preserved. A retrospective chart review was performed of 10 patients who underwent trapezius muscle flap for posterior neck and scalp defects. We also performed an anatomical study of 16 flaps harvested from 8 preserved Asian adult cadavers and evaluated the main landmarks relevant for trapezius muscle flap. In the anatomical study, the mean vertical height from the inferior angle of the scapula to the point at which the superficial cervical artery penetrated the trapezius was 4.31±2.14 cm. The mean vertical height of the trapezius muscle flap pivot point was 9.53±2.08 cm from the external occipital protuberance. Among the 10 flaps, partial necrosis on the overlaid skin graft occurred in 1 patient and postoperative seroma occurred in another patient. Vascular variations in the trapezius muscle flap are uncommon in Asians, but when present, such variations appear to have little impact on harvesting the flap or on its circulation. The trapezius muscle flap is a viable alternative for posterior neck and scalp reconstruction.
The Trapezius Muscle Flap: A Viable Alternative for Posterior Scalp and Neck Reconstruction
Yang, Hee Jun; Kim, Yang Woo; Lee, Sang Gu
2016-01-01
Background The trapezius muscle flap is not usually the first reconstructive option for skin and soft tissue defects in the posterior neck and scalp due to surgeons' unfamiliarity with the surgical anatomy and developments in free tissue transfer techniques. The goals of this study were to describe the clinical use of trapezius flaps in posterior neck and scalp reconstruction, and to investigate the vascular anatomy of trapezius flaps in Asians in order to obtain information facilitating the safe design and elevation of flaps in which most of the muscle is preserved. Methods A retrospective chart review was performed of 10 patients who underwent trapezius muscle flap for posterior neck and scalp defects. We also performed an anatomical study of 16 flaps harvested from 8 preserved Asian adult cadavers and evaluated the main landmarks relevant for trapezius muscle flap. Results In the anatomical study, the mean vertical height from the inferior angle of the scapula to the point at which the superficial cervical artery penetrated the trapezius was 4.31±2.14 cm. The mean vertical height of the trapezius muscle flap pivot point was 9.53±2.08 cm from the external occipital protuberance. Among the 10 flaps, partial necrosis on the overlaid skin graft occurred in 1 patient and postoperative seroma occurred in another patient. Conclusions Vascular variations in the trapezius muscle flap are uncommon in Asians, but when present, such variations appear to have little impact on harvesting the flap or on its circulation. The trapezius muscle flap is a viable alternative for posterior neck and scalp reconstruction. PMID:27896183
Jia, Xiaotian; Chen, Chao; Yang, Jianyun; Yu, Cong
2018-06-01
The phrenic nerve being transferred to the posterior division of the lower trunk with end-to-end neurorrhaphy is reported to be effective in restoring the function of digit extension in literature. However, the phrenic nerve is extremely important in respiration. We designed an animal experiment to discover whether the phrenic nerve being transferred to the posterior division of the lower trunk with end-to-side neurotization was feasible and provided the theoretical basis. A sum of 36 Sprague-Dawley rats was randomly assigned to one of two groups. In Group A, the phrenic nerve was transferred to the posterior division of the lower trunk with end-to-side neurotization. In Group B, the posterior division of the lower trunk was directly sutured. The results of behavioral assessment, electrophysiology, histology and nerve fiber count and muscle weight at 12 weeks postoperatively were recorded. In Group A, none of the rats experienced tachypnea. The motion of slight toe extension was observed. The results of electrophysiology, histology and nerve fiber count and muscle weight in Group A were not as well as those of Group B, but gradually improved with time. The phrenic nerve being transferred to the posterior division of lower trunk with end-to-side neurotization can partially restore the function of toe extension in a rat model. Whether the function of digit extension can be restored by the phrenic nerve with end-to-side neurotization in humans still needs more practice in clinic.
Location of Rotator Cuff Tear Initiation: A Magnetic Resonance Imaging Study of 191 Shoulders.
Jeong, Jeung Yeol; Min, Seul Ki; Park, Keun Min; Park, Yong Bok; Han, Kwang Joon; Yoo, Jae Chul
2018-03-01
Degenerative rotator cuff tears (RCTs) are generally thought to originate at the anterior margin of the supraspinatus tendon. However, a recent ultrasonography study suggested that they might originate more posteriorly than originally thought, perhaps even from the isolated infraspinatus (ISP) tendon, and propagate toward the anterior supraspinatus. Hypothesis/Purpose: It was hypothesized that this finding could be reproduced with magnetic resonance imaging (MRI). The purpose was to determine the most common location of degenerative RCTs by using 3-dimensional multiplanar MRI reconstruction. It was assumed that the location of the partial-thickness tears would identify the area of the initiation of full-thickness tears. Cross-sectional study; Level of evidence, 3. A retrospective analysis was conducted including 245 patients who had RCTs (nearly full- or partial-thickness tears) at the outpatient department between January 2011 and December 2013. RCTs were measured on 3-dimensional multiplanar reconstruction MRI with OsiriX software. The width and distance from the biceps tendon to the anterior margin of the tear were measured on T2-weighted sagittal images. In a spreadsheet, columns of consecutive numbers represented the size of each tear (anteroposterior width) and their locations with respect to the biceps brachii tendon. Data were pooled to graphically represent the width and location of all tears. Frequency histograms of the columns were made to visualize the distribution of tears. The tears were divided into 2 groups based on width (group A, <10 mm; group B, <20 and ≥10 mm) and analyzed for any differences in location related to size. The mean width of all RCTs was 11.9 ± 4.1 mm, and the mean length was 11.1 ± 5.0 mm. Histograms showed the most common location of origin to be 9 to 10 mm posterior to the biceps tendon. The histograms of groups A and B showed similar tear location distributions, indicating that the region approximately 10 mm posterior to the biceps tendon is the most common site of tear initiation. These results demonstrate that degenerative RCTs most commonly originate from approximately 9 to 10 mm posterior to the biceps tendon.
Sun, Cong; Zhao, Jinxiu; Jianghao, Chen; Hong, Tao
2016-12-01
The objective of this study was to evaluate the implant stability and peri-implant tissue response in heavy smokers receiving dental implants due to partially edentulous posterior mandibles. Forty-five ITI Straumann dental implants were placed into the partially edentulous posterior mandibles of 16 heavy smokers and 16 nonsmokers. One implant in each patient was evaluated for implant stability after surgery and before loading, and for the modified plaque index (mPLI), modified sulcus bleeding index (mSBI), probing depth (PD), and marginal bone loss (MBL) after loading. Meanwhile, the osteogenic capability of jaw marrow samples collected from patients was evaluated via an in vitro mineralization test. For both groups, the implant stability quotient (ISQ) initially decreased from the initial ISQ achieved immediately after surgery and then increased starting from 2 weeks postsurgery. However, at 3, 4, 6, and 8 weeks postsurgery, the ISQ differed significantly between nonsmokers and heavy smokers. All implants achieved osseointegration without complications at least by the end of the 12th week postsurgery. At 6 or 12 months postloading, the MBL and PD were significantly higher in heavy smokers than in nonsmokers, whereas the mSBI and mPLI did not differ significantly between the 2 groups. The 1-year cumulative success rate of implants was 100% for both groups. Within the limitations of the present clinical study (such as small sample size and short study duration), which applied the loading at 3 months postoperation, heavy smoking did not affect the cumulative survival rate of dental implants placed at the posterior mandible in male patients, but heavy smoking did negatively affect bone healing around dental implants by decreasing the healing speed. These results implied that it might be of importance to select the right time point to apply the implant loading for heavy smokers. In addition, heavy smoking promoted the loss of marginal bone and the further development of dental pockets. Further clinical studies with larger patient populations are warranted to confirm our findings over a longer study duration.
48 CFR 49.603-2 - Fixed-price contracts-partial termination.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Contractor transfers, conveys, and assigns to the Government all the right, title, and interest, if any, that... relating to price reductions for defective certified cost or pricing data. (End of agreement) [48 FR 42447...
Yokoyama, Daiichiro; Shinya, Akikazu; Gomi, Harunori; Vallittu, Pekka K; Shinya, Akiyoshi
2012-01-01
Using finite element analysis (FEA), this study investigated the effects of the mechanical properties of adhesive resin cements on stress distributions in fiber-reinforced resin composite (FRC) adhesive fixed partial dentures (AFPDs). Two adhesive resin cements were compared: Super-Bond C&B and Panavia Fluoro Cement. The AFPD consisted of a pontic to replace a maxillary right lateral incisor and retainers on a maxillary central incisor and canine. FRC framework was made of isotropic, continuous, unidirectional E-glass fibers. Maximum principal stresses were calculated using finite element method (FEM). Test results revealed that differences in the mechanical properties of adhesive resin cements led to different stress distributions at the cement interfaces between AFPD and abutment teeth. Clinical implication of these findings suggested that the safety and longevity of an AFPD depended on choosing an adhesive resin cement with the appropriate mechanical properties.
A simple way to intrude overerupted upper second molars with miniscrews.
Cao, Yang; Liu, Chufeng; Wang, Chunxian; Yang, Xiaoyu; Duan, Peijia; Xu, Chenrong
2013-12-01
Various methods of using skeletal anchorage for the intrusion of overerupted maxillary molars have been reported; however, it is difficult to intrude the overerupted upper second molars because of the low bone density in the region of the tuberosity. This article illustrates a new treatment method using partial fixed edgewise appliances and miniscrews to intrude the overerupted upper second molars. The miniscrews were applied to reinforce the anchorage of the upper first molar. The intrusive force was generated by the Ni-Ti wire. The clinical results showed a significant intrusion effect without root resorption or periodontal problems. This report demonstrates that the combination of partial conventional fixed appliances with miniscrews is a simple and effective treatment option to intrude overerupted upper second molars, especially in situations where miniscrews cannot be inserted directly next to the second molar. © 2013 by the American College of Prosthodontists.
Mamoun, John S.
2013-01-01
The abutment(s) of a partial fixed dental prosthesis (PFDP) should have a minimal total occlusal convergence (TOC), also called a taper, in order to ensure adequate retention of a PFDP that will be made for the abutment(s), given the height of the abutment(s). This article reviews the concept of PFDP abutment TOC and presents an alternative definition of what TOC is, defining it as the extent to which the shape of an abutment differs from an ideal cylinder shape of an abutment. This article also reviews experimental results concerning what is the ideal TOC in degrees and explores clinical techniques of estimating the TOC of a crown abutment. The author suggests that Dentists use high magnification loupes (×6-8 magnification or greater) or a surgical operating microscope when preparing crown abutments, to facilitate creating a minimum abutment TOC. PMID:24932130
Kanna, Rishi M; Shetty, Ajoy P; Rajasekaran, S
2018-06-01
Surgical reduction of uni and bi-facetal dislocations of the cervical spine (AO type C injuries) can be performed by posterior, anterior or combined approaches. Ease of access, low infection rates and less risks of neurological worsening has popularized anterior approach. However, the reduction of locked cervical facets can be intricate through anterior approach. We analyzed the safety, efficacy and outcomes at a minimum 1 year, of a novel anterior reduction technique for consecutively treated cervical facet dislocations. Patients with single level traumatic sub-axial cervical dislocation (n = 39) treated by this modified anterior technique were studied. The technique involved standard Smith-Robinson approach, discectomy beyond PLL, use of inter-laminar distracter to distract while Caspar pins were used as "joysticks" (either flexion-extension or lateral rotation moments are provided), to reduce the sub-luxed facets. Among 51 patients with cervical type C injury treated during the study period, 4 patients who had spontaneous reduction and 8 treated by planned global fusion were excluded. 39 patients of mean age 49.9 years were studied. The levels of injury included (C3-4 = 2, C4-5 = 5, C5-6 = 20, C6-7 = 12). 18 were bi-facetal and 21 were uni-facetal dislocation. One facet was fractured in 17 and both in 5 patients. 30% (n = 13) had a concomitant disc prolapse. The neurological status was as follows: 9 ASIA A, 9 ASIA C, 13 ASIA D and 8 ASIA E. All the patients were successfully reduced by this technique and fixed with anterior locking cervical locking plates. No supplemental posterior surgery was performed. 22 patients with incomplete deficit showed recovery. The mean follow-up was 14.3 months and there was no implant failure except one patient who had partial loss of the reduction. Patients with traumatic sub-axial cervical dislocation (AO type C injuries) can be safely and effectively reduced by this technique. Other advantages include minimal blood loss, less risks of infection, shorted fusion zone, good fusion rate and neurological recovery.
Pancreas anatomy and surgical procedure for pancreatectomy in rhesus monkeys.
Zhang, Yi; Fu, Lan; Lu, Yan-Rong; Guo, Zhi-Guang; Zhang, Zhao-Da; Cheng, Jing-Qiu; Hu, Wei-Ming; Liu, Xu-Bao; Mai, Gang; Zeng, Yong; Tian, Bo-Le
2011-12-01
The aim of this study was to investigate the pancreas anatomy and surgical procedure for harvesting pancreas for islet isolation while performing pancreatectomy to induce diabetes in rhesus monkeys. The necropsy was performed in three cadaveric monkeys. Two monkeys underwent the total pancreatectomy and four underwent partial pancreatectomy (70-75%). The greater omentum without ligament to transverse colon, the cystic artery arising from the proper hepatic artery and the branches supplying the paries posterior gastricus from the splenic artery were observed. For pancreatectomy, resected pancreas can be used for islet isolation. Diabetes was not induced in the monkeys undergoing partial pancreatectomy (70-75%). Pancreas anatomy in rhesus monkeys is not the same as in human. Diabetes can be induced in rhesus monkeys by total but not partial pancreatectomy (70-75%). Resected pancreas can be used for islet isolation while performing pancreatectomy to induce diabetes. © 2011 John Wiley & Sons A/S.
Congenital Partial Absence of Trapezius with Variant Pattern of Rectus Sheath.
Tigga, Sarika Rachel; Goswami, Preeti; Khanna, Jugesh
2016-04-01
Musculocutaneous pedicled/free flaps are an essential prerequisite for reconstructive surgery. Amongst the trunk muscles commonly harvested for flaps, the trapezius and rectus abdominis provide satisfactory coverage for cranial and trunk defects. unilateral/bilateral or partial congenital absence of trapezius muscle is well documented and may result in muscular imbalances compromising posture and limb movements. During routine cadaveric dissection, we encountered a case of bilateral partial absence of occipital part of the trapezius muscle. Concurrently, the ventral abdominal musculature displayed the aponeurosis of transversus abdominis muscle solely forming the posterior wall of the rectus sheath. These conjointly occurring anomalies advocate a compensatory strengthening of the anterior wall of rectus sheath in response to the congenital absence of occipital part of the trapezius, probably to counteract the postural instability. The present study focuses on recognition of compensatory mechanisms resulting from congenital variations as identification of such processes may prevent chronic debilitating conditions.
Ultrasound-assisted endoscopic partial plantar fascia release.
Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa
2013-01-01
Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure.
Ultrasound-Assisted Endoscopic Partial Plantar Fascia Release
Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa
2013-01-01
Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure. PMID:24265989
Non-linear dynamics of compound sawteeth in tokamaks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahn, J.-H., E-mail: jae-heon.ahn@polytechnique.edu; Garbet, X.; Sabot, R.
2016-05-15
Compound sawteeth is studied with the XTOR-2F code. Non-linear full 3D magnetohydrodynamic simulations show that the plasma hot core is radially displaced and rotates during the partial crash, but is not fully expelled out of the q = 1 surface. Partial crashes occur when the radius of the q = 1 surface exceeds a critical value, at fixed poloidal beta. This critical value depends on the plasma elongation. The partial crash time is larger than the collapse time of an ordinary sawtooth, likely due to a weaker diamagnetic stabilization. This suggests that partial crashes result from a competition between destabilizing effects such as themore » q = 1 radius and diamagnetic stabilization.« less
The Superior Labrum, Anterior-to-Posterior ’SLAP’ Lesion
2006-10-01
and optimize surgical outcomes. Shoulder arthroscopy is the mainstay of diagnosis and treatment for most patients with SLAP lesions (1). A...complete diagnostic arthroscopy should include an inspection of the rotator cuff for associated partial thickness or full- thickness tears and inspection of...Karzel RP, Del Pizzo, W, et al: SLAP lesions of the shoulder. Arthroscopy 1990; 6:274-279. 2 Sanders TG, Morrison WB, and Miller, MD: Imaging
Sun, Chuan-bin; You, Yong-sheng; Liu, Zhe; Zheng, Lin-yan; Chen, Pei-qing; Yao, Ke; Xue, An-quan
2016-01-01
To investigate the morphological characteristics of myopic macular retinoschisis (MRS) in teenagers with high myopia, six male (9 eyes) and 3 female (4 eyes) teenagers with typical MRS identified from chart review were evaluated. All cases underwent complete ophthalmic examinations including best corrected visual acuity (BCVA), indirect ophthalmoscopy, colour fundus photography, B-type ultrasonography, axial length measurement, and spectral-domain optical coherence tomography (SD-OCT). The average age was 17.8 ± 1.5 years, average refractive error was −17.04 ± 3.04D, average BCVA was 0.43 ± 0.61, and average axial length was 30.42 ± 1.71 mm. Myopic macular degenerative changes (MDC) by colour fundus photographs revealed Ohno-Matsui Category 1 in 4 eyes, and Category 2 in 9 eyes. Posterior staphyloma was found in 9 eyes. SD-OCT showed outer MRS in all 13 eyes, internal limiting membrane detachment in 7 eyes, vascular microfolds in 2 eyes, and inner MRS in 1 eye. No premacular structures such as macular epiretinal membrane or partially detached posterior hyaloids were found. Our results showed that MRS rarely occurred in highly myopic teenagers, and was not accompanied by premacular structures, severe MDC, or even obvious posterior staphyloma. This finding indicates that posterior scleral expansion is probably the main cause of MRS. PMID:27294332
Travan, Luciana; Saccheri, Paola; Sabbadini, Gastone; Crivellato, Enrico
2011-08-01
We observed a complex atlas (C1) dysmorphism in a human medieval skeleton dug up from the sixth to the seventh century necropolis located in the north-eastern Italy. We analyzed such a dysmorphism in the light of pertinent literature and discussed the functional and clinical implications related to this type of C1 structural malformation. Macroscopical and CT-SCAN examinations of the atlas were carried out. Bone findings consisted of partial aplasia of the posterior arch of the C1 accompanied by a bilateral arcuate foramen. In addition, the spinous processes of C7 and T1 were found to be bifid. Although such abnormalities are supposed to be clinically inconspicuous, yet they may become challenging or even dangerous in the context of trauma. They may even complicate specific diagnostic or surgical procedures. In addition, they may cause a great number of symptoms, ranging from headache and neck pain to loss of postural muscle tone and consciousness, due to the close and complex relationship of bone structures with nerves, blood vessels, muscles, and ligaments. As a result, radiologists, clinicians, surgeons, and chiropractors should consider in their clinical reasoning the possibility that atlas dysmorphisms may occur.
Ihara, H; Miwa, M; Takayanagi, K; Nakayama, A
1994-10-01
The purpose of this study was to evaluate arthroscopically the natural healing of an acute torn meniscus combined with an acute cruciate ligament injury treated nonoperatively. There were 30 lateral and 10 medial meniscus tears associated with 25 acute anterior cruciate ligament and 7 posterior cruciate ligament injuries in 32 patients. There was more than 1 tear on some menisci for a total of 51 tear sites. Injuries to the menisci and ligaments were allowed to heal without surgery, but were given protective mobilization immediately in order to stimulate stress oriented healing of injured collagen fibers and promote circulation of synovial fluid to the meniscus and ligament. A Kyuro knee brace with a coil spring traction system was used to add adequate but not excessive stress to the associated injured cruciate ligament. All knees were examined and arthroscoped before and after a 3-month treatment period. Results indicated that 69% of the lateral menisci healed completely and 18% healed partially, whereas 58% of the medial menisci healed completely and none healed partially. Twenty of 25 anterior cruciate ligaments and 3 of 7 posterior cruciate ligaments healed satisfactorily. This study indicated that acute tears of the meniscus, even when they occur in association with a cruciate ligament injury, can heal morphologically with nonsurgical treatment.
The use of solution adaptive grids in solving partial differential equations
NASA Technical Reports Server (NTRS)
Anderson, D. A.; Rai, M. M.
1982-01-01
The grid point distribution used in solving a partial differential equation using a numerical method has a substantial influence on the quality of the solution. An adaptive grid which adjusts as the solution changes provides the best results when the number of grid points available for use during the calculation is fixed. Basic concepts used in generating and applying adaptive grids are reviewed in this paper, and examples illustrating applications of these concepts are presented.
1997-06-10
been in the area of implantology . Recent advances in dental titanium casting machines allow for the use of titanium for crowns, fixed partial dentures...medical implant prostheses (McKinney and Lemons, 1985; Williams, 1981). By the end of the 1960s, titanium found a niche in dental implantology ...as an implant or restorative material. In the field of dental implantology , evidence suggests that metal corrosion and allergenicity may be important
Gobbi, Riccardo Gomes; Pereira, César Augusto Martins; Sadigursky, David; Demange, Marco Kawamura; Tírico, Luis Eduardo Passarelli; Pécora, José Ricardo; Camanho, Gilberto Luis
2016-10-01
The location of patellar and femoral fixation of the graft in medial patellofemoral ligament reconstructions has been widely discussed. This study aimed to assess the distances between different patellar and femoral fixation points to identify the least anisometric pairs of points. Ten cadaver knees were attached to an apparatus that simulated an active range of motion of 120°, with three metallic markers fixed onto the medial side of the patella, and seven markings onto the medial epicondyle. The examined points included the proximal patella pole (1), the patellar center (3), the midpoint between points 1 and 3 (2), a point directly on the epicondyle (6), points 5mm anterior (5) and posterior (7) to the epicondyle, points 5mm anterior to point 5 (4) and 5mm posterior to point 7 (8), and points 5mm proximal (9) and distal (10) to the epicondyle. The distances between patella and femur points were measured by a photogrammetry system at 15° intervals. The pair of points that exhibited the lowest average variability in distance, and hence was the most isometric, was the patella center combined with the anterior to the medial femoral epicondyle. The pairs of points that exhibited the highest average variability in distance, and hence were the least isometric, were the ones located distal or posterior to the medial femoral epicondyle, with less influence by the patellar location. Surgeons should avoid positioning the graft distally or posterior to the epicondyle due to the increase in anisometry. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Hou, Yanqing; Verhagen, Sandra; Wu, Jie
2016-12-01
Ambiguity Resolution (AR) is a key technique in GNSS precise positioning. In case of weak models (i.e., low precision of data), however, the success rate of AR may be low, which may consequently introduce large errors to the baseline solution in cases of wrong fixing. Partial Ambiguity Resolution (PAR) is therefore proposed such that the baseline precision can be improved by fixing only a subset of ambiguities with high success rate. This contribution proposes a new PAR strategy, allowing to select the subset such that the expected precision gain is maximized among a set of pre-selected subsets, while at the same time the failure rate is controlled. These pre-selected subsets are supposed to obtain the highest success rate among those with the same subset size. The strategy is called Two-step Success Rate Criterion (TSRC) as it will first try to fix a relatively large subset with the fixed failure rate ratio test (FFRT) to decide on acceptance or rejection. In case of rejection, a smaller subset will be fixed and validated by the ratio test so as to fulfill the overall failure rate criterion. It is shown how the method can be practically used, without introducing a large additional computation effort. And more importantly, how it can improve (or at least not deteriorate) the availability in terms of baseline precision comparing to classical Success Rate Criterion (SRC) PAR strategy, based on a simulation validation. In the simulation validation, significant improvements are obtained for single-GNSS on short baselines with dual-frequency observations. For dual-constellation GNSS, the improvement for single-frequency observations on short baselines is very significant, on average 68%. For the medium- to long baselines, with dual-constellation GNSS the average improvement is around 20-30%.
Zafiropoulos, Gregory-George; Hoffman, Oliver
2011-01-01
Dental implants as abutments for full-arch restorations are a well-documented treatment modality. This report presents a case in which the patient was treated initially with fixed restorations supported by either implants or natural teeth and subsequently treated with a removable implant/telescopic crown-supported overdenture. Advantages and disadvantages of each approach are described and discussed. While the fixed restoration resulted in a functionally satisfactory treatment outcome, the patient was displeased with the esthetic appearance. The main concern was the unnaturally long tooth shape necessary to compensate for the insufficient alveolar ridge height. Replacement of the existing restoration with an implant-supported removable overdenture led to a functionally and esthetically acceptable result. When deciding whether to use a fixed or removable implant-supported full-arch restoration, a multitude of factors must be considered. Due to the possible need for additional surgical steps to enhance the esthetic appearance surrounding fixed restorations, removable implant-supported partial dentures often are the better choice.
NASA Astrophysics Data System (ADS)
Zhou, Feng; Chen, Guoxian; Huang, Yuefei; Yang, Jerry Zhijian; Feng, Hui
2013-04-01
A new geometrical conservative interpolation on unstructured meshes is developed for preserving still water equilibrium and positivity of water depth at each iteration of mesh movement, leading to an adaptive moving finite volume (AMFV) scheme for modeling flood inundation over dry and complex topography. Unlike traditional schemes involving position-fixed meshes, the iteration process of the AFMV scheme moves a fewer number of the meshes adaptively in response to flow variables calculated in prior solutions and then simulates their posterior values on the new meshes. At each time step of the simulation, the AMFV scheme consists of three parts: an adaptive mesh movement to shift the vertices position, a geometrical conservative interpolation to remap the flow variables by summing the total mass over old meshes to avoid the generation of spurious waves, and a partial differential equations(PDEs) discretization to update the flow variables for a new time step. Five different test cases are presented to verify the computational advantages of the proposed scheme over nonadaptive methods. The results reveal three attractive features: (i) the AMFV scheme could preserve still water equilibrium and positivity of water depth within both mesh movement and PDE discretization steps; (ii) it improved the shock-capturing capability for handling topographic source terms and wet-dry interfaces by moving triangular meshes to approximate the spatial distribution of time-variant flood processes; (iii) it was able to solve the shallow water equations with a relatively higher accuracy and spatial-resolution with a lower computational cost.
The effect of mucosal cuff shrinkage around dental implants during healing abutment replacement.
Nissan, J; Zenziper, E; Rosner, O; Kolerman, R; Chaushu, L; Chaushu, G
2015-10-01
Soft tissue shrinkage during the course of restoring dental implants may result in biological and prosthodontic difficulties. This study was conducted to measure the continuous shrinkage of the mucosal cuff around dental implants following the removal of the healing abutment up to 60 s. Individuals treated with implant-supported fixed partial dentures were included. Implant data--location, type, length, diameter and healing abutments' dimensions--were recorded. Mucosal cuff shrinkage, following removal of the healing abutments, was measured in bucco-lingual direction at four time points--immediately after 20, 40 and 60 s. anova was used to for statistical analysis. Eighty-seven patients (49 women and 38 men) with a total of 311 implants were evaluated (120 maxilla; 191 mandible; 291 posterior segments; 20 anterior segments). Two-hundred and five (66%) implants displayed thick and 106 (34%) thin gingival biotype. Time was the sole statistically significant parameter affecting mucosal cuff shrinkage around dental implants (P < 0.001). From time 0 to 20, 40 and 60 s, the mean diameter changed from 4.1 to 4.07, 3.4 and 2.81 mm, respectively. The shrinkage was 1%, 17% and 31%, respectively. The gingival biotype had no statistically significant influence on mucosal cuff shrinkage (P = 0.672). Time required replacing a healing abutment with a prosthetic element should be minimised (up to 20/40 s), to avoid pain, discomfort and misfit. © 2015 John Wiley & Sons Ltd.
Chung, Kyu Sung; Ha, Jeong Ku; Yeom, Cheol Hyun; Ra, Ho Jong; Jang, Ho Su; Choi, Seung Hyuk; Kim, Jin Goo
2015-10-01
To compare the clinical and radiologic results of partial meniscectomy with those of refixation in patients with medial meniscus posterior root tears (MMPRTs) at a minimum 5-year follow-up. Between 2005 and 2009, patients with MMPRTs who had been followed up for at least 5 years after a partial meniscectomy (group M, n = 20) or pullout repair (group R, n = 37) were recruited. The mean follow-up duration was 67.5 months in group M and 72.0 months in group R. Clinical assessments, including the Lysholm score and International Knee Documentation Committee (IKDC) Subjective Knee Form score, and radiographic assessments, including the Kellgren-Lawrence (K-L) grade and medial joint space width, were evaluated preoperatively and at final follow-up. We compared the preoperative results with the final results in each group, and we compared the final results of groups M and R. Five-year survival rates were also evaluated. The mean Lysholm score (P = .039) and IKDC score (P = .037) improved significantly. However, the width of the medial joint space (P < .001) and K-L grade (P < .001) worsened significantly in both groups. When we compared the final results, group R had significantly better Lysholm scores (P = .002) and IKDC scores (P < .001) than group M. Group R showed less K-L grade progression (P = .005) and less medial joint space narrowing (P < .001) than group M. The rate of conversion to total knee arthroplasty was 35% in group M, whereas there was no conversion to total knee arthroplasty in group R. The 5-year survival rates in groups M and R were 75% and 100%, respectively (P < .001). For MMPRTs, refixation was more effective than partial meniscectomy in terms of the clinical and radiologic outcomes and survival for at least 5 years' follow-up. Refixation slowed the progression of arthritic changes compared with partial meniscectomy, although it did not prevent the progression of arthrosis completely. Level III, retrospective comparative study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
A Bayesian predictive two-stage design for phase II clinical trials.
Sambucini, Valeria
2008-04-15
In this paper, we propose a Bayesian two-stage design for phase II clinical trials, which represents a predictive version of the single threshold design (STD) recently introduced by Tan and Machin. The STD two-stage sample sizes are determined specifying a minimum threshold for the posterior probability that the true response rate exceeds a pre-specified target value and assuming that the observed response rate is slightly higher than the target. Unlike the STD, we do not refer to a fixed experimental outcome, but take into account the uncertainty about future data. In both stages, the design aims to control the probability of getting a large posterior probability that the true response rate exceeds the target value. Such a probability is expressed in terms of prior predictive distributions of the data. The performance of the design is based on the distinction between analysis and design priors, recently introduced in the literature. The properties of the method are studied when all the design parameters vary.
Fujii, Masataka; Furumatsu, Takayuki; Xue, Haowei; Miyazawa, Shinichi; Kodama, Yuya; Hino, Tomohito; Kamatsuki, Yusuke; Ozaki, Toshifumi
2017-10-01
The purpose of this study was to compare the load-to-failure of different common suturing techniques with a new technique for the medial meniscus posterior root tear (MMPRT). Thirty porcine medial menisci were randomly assigned to three suturing techniques used for transtibial pullout repair of the MMPRT (n = 10 per group). Three different meniscal suture configurations were studied: the two simple suture (TSS) technique, the conventional modified Mason-Allen suture (MMA) technique, and the new MMA technique using the FasT-Fix combined with the Ultrabraid (F-MMA). The ultimate failure load was tested using a tensile testing machine. The MMA and F-MMA groups demonstrated significantly higher failure loads than the TSS group (P = 0.0003 and P = 0.0005, respectively). No significant differences were observed between the MMA and F-MMA groups (P = 0.734). The ultimate failure load was significantly greater in the F-MMA than the TSS group and similar to the conventional MMA technique.
Nakagawa, Shuji; Arai, Yuji; Hara, Kunio; Inoue, Hiroaki; Hino, Manabu; Kubo, Toshikazu
2017-01-01
We describe a patient who underwent arthroscopic pullout fixation for a posterior cruciate ligament (PCL) avulsion fracture. A 46-year-old female, injured in a fall while riding a motorcycle, was diagnosed with a right knee PCL tibial attachment avulsion fracture and underwent arthroscopic osteosynthesis. A Kirschner wire was drilled to a point just medial to the medial border of the anterior tibial bony bed. A suture wire was folded into a loop and introduced into the posteromedial compartment via the bone tunnel. A fixation thread was inserted from the posteromedial portal, through the medial and lateral loop wires, and into the posteromedial compartment. The lateral and medial loop wires attached to the thread were pulled to the outside, and the thread was fixed onto the tibia. Three months post-surgery, she returned to her job. This procedure represents a minimally invasive method of treating avulsion fractures of the tibial attachment of the PCL. PMID:29172392
Pulse-encoded ultrasound imaging of the vitreous with an annular array.
Silverman, Ronald H; Ketterling, Jeffrey A; Mamou, Jonathan; Lloyd, Harriet O; Filoux, Erwan; Coleman, D Jackson
2012-01-01
The vitreous body is nearly transparent both optically and ultrasonically. Conventional 10- to 12-MHz diagnostic ultrasound can detect vitreous inhomogeneities at high gain settings, but has limited resolution and sensitivity, especially outside the fixed focal zone near the retina. To improve visualization of faint intravitreal fluid/gel interfaces, the authors fabricated a spherically curved 20-MHz five-element annular array ultrasound transducer, implemented a synthetic-focusing algorithm to extend the depth-of-field, and used a pulse-encoding strategy to increase sensitivity. The authors evaluated a human subject with a recent posterior vitreous detachment and compared the annular array with conventional 10-MHz ultrasound and spectral-domain optical coherence tomography. With synthetic focusing and chirp pulse-encoding, the array allowed visualization of the formed and fluid components of the vitreous with improved sensitivity and resolution compared with the conventional B-scan. Although optical coherence tomography allowed assessment of the posterior vitreoretinal interface, the ultrasound array allowed evaluation of the entire vitreous body. Copyright 2012, SLACK Incorporated.
Importance of tibial slope for stability of the posterior cruciate ligament deficient knee.
Giffin, J Robert; Stabile, Kathryne J; Zantop, Thore; Vogrin, Tracy M; Woo, Savio L-Y; Harner, Christopher D
2007-09-01
Previous studies have shown that increasing tibial slope can shift the resting position of the tibia anteriorly. As a result, sagittal osteotomies that alter slope have recently been proposed for treatment of posterior cruciate ligament (PCL) injuries. Increasing tibial slope with an osteotomy shifts the resting position anteriorly in a PCL-deficient knee, thereby partially reducing the posterior tibial "sag" associated with PCL injury. This shift in resting position from the increased slope causes a decrease in posterior tibial translation compared with the PCL-deficient knee in response to posterior tibial and axial compressive loads. Controlled laboratory study. Three knee conditions were tested with a robotic universal force-moment sensor testing system: intact, PCL-deficient, and PCL-deficient with increased tibial slope. Tibial slope was increased via a 5-mm anterior opening wedge osteotomy. Three external loading conditions were applied to each knee condition at 0 degrees, 30 degrees, 60 degrees, 90 degrees, and 120 degrees of knee flexion: (1) 134-N anterior-posterior (A-P) tibial load, (2) 200-N axial compressive load, and (3) combined 134-N A-P and 200-N axial loads. For each loading condition, kinematics of the intact knee were recorded for the remaining 5 degrees of freedom (ie, A-P, medial-lateral, and proximal-distal translations, internal-external and varus-valgus rotations). Posterior cruciate ligament deficiency resulted in a posterior shift of the tibial resting position to 8.4 +/- 2.6 mm at 90 degrees compared with the intact knee. After osteotomy, tibial slope increased from 9.2 degrees +/- 1.0 degrees in the intact knee to 13.8 degrees +/- 0.9 degrees. This increase in slope reduced the posterior sag of the PCL-deficient knee, shifting the resting position anteriorly to 4.0 +/- 2.0 mm at 90 degrees. Under a 200-N axial compressive load with the osteotomy, an additional increase in anterior tibial translation to 2.7 +/- 1.7 mm at 30 degrees was observed. Under a 134-N A-P load, the osteotomy did not significantly affect total A-P translation when compared with the PCL-deficient knee. However, because of the anterior shift in resting position, there was a relative decrease in posterior tibial translation and increase in anterior tibial translation. Increasing tibial slope in a PCL-deficient knee reduces tibial sag by shifting the resting position of the tibia anteriorly. This sag is even further reduced when the knee is subjected to axial compressive loads. These data suggest that increasing tibial slope may be beneficial for patients with PCL-deficient knees.
Gamma knife radiosurgery for skull-base meningiomas.
Takanashi, Masami; Fukuoka, Seiji; Hojyo, Atsufumi; Sasaki, Takehiko; Nakagawara, Jyoji; Nakamura, Hirohiko
2009-01-01
The primary purpose of this study was to evaluate the efficacy of gamma knife radiosurgery (GKRS) when used as a treatment modality for cavernous sinus or posterior fossa skull-base meningiomas (SBMs), with particular attention given to whether or not intentional partial resection followed by GKRS constitutes an appropriate combination treatment method for larger SBMs. Of the 101 SBM patients in this series, 38 were classified as having cavernous sinus meningiomas (CSMs), and 63 presented with posterior fossa meningiomas (PFMs). The patients with no history of prior surgery (19 CSMs, 57 PFMs) were treated according to a set protocol. Small to medium-sized SBMs were treated by GKRS only. To minimize the risk of functional deficits, larger tumors were treated with the combination of intentional partial resection followed by GKRS. Residual or recurrent tumors in patients who had undergone extirpations prior to GKRS (19 CSMs, 6 PFMs) are not eligible for this treatment method (due to the surgeries not being performed as part of a combination strategy designed to preserve neurological function as the first priority). The mean follow-up period was 51.9 months (range, 6-144 months). The overall tumor control rates were 95.5% in CSMs and 98.4% in PFMs. Nearly all tumors treated with GKRS alone were well controlled and the patients had no deficits. Furthermore, none of the patients who had undergone prior surgeries experienced new neurological deficits after GKRS. While new neurological deficits appeared far less often in those receiving the combination of partial resection with subsequent GKRS, extirpations tended to be associated with not only a higher incidence of new deficits but also a significant increase in the worsening of already-existing deficits. Our results indicate that GKRS is a safe and effective primary treatment for SBMs with small to moderate tumor volumes. We also found that larger SBMs compressing the optic pathway or brain stem can be effectively treated, minimizing any possible functional damage, by a combination of partial resection with subsequent GKRS.
Antal, Péter; Kiszel, Petra Sz.; Gézsi, András; Hadadi, Éva; Virág, Viktor; Hajós, Gergely; Millinghoffer, András; Nagy, Adrienne; Kiss, András; Semsei, Ágnes F.; Temesi, Gergely; Melegh, Béla; Kisfali, Péter; Széll, Márta; Bikov, András; Gálffy, Gabriella; Tamási, Lilla; Falus, András; Szalai, Csaba
2012-01-01
Genetic studies indicate high number of potential factors related to asthma. Based on earlier linkage analyses we selected the 11q13 and 14q22 asthma susceptibility regions, for which we designed a partial genome screening study using 145 SNPs in 1201 individuals (436 asthmatic children and 765 controls). The results were evaluated with traditional frequentist methods and we applied a new statistical method, called Bayesian network based Bayesian multilevel analysis of relevance (BN-BMLA). This method uses Bayesian network representation to provide detailed characterization of the relevance of factors, such as joint significance, the type of dependency, and multi-target aspects. We estimated posteriors for these relations within the Bayesian statistical framework, in order to estimate the posteriors whether a variable is directly relevant or its association is only mediated. With frequentist methods one SNP (rs3751464 in the FRMD6 gene) provided evidence for an association with asthma (OR = 1.43(1.2–1.8); p = 3×10−4). The possible role of the FRMD6 gene in asthma was also confirmed in an animal model and human asthmatics. In the BN-BMLA analysis altogether 5 SNPs in 4 genes were found relevant in connection with asthma phenotype: PRPF19 on chromosome 11, and FRMD6, PTGER2 and PTGDR on chromosome 14. In a subsequent step a partial dataset containing rhinitis and further clinical parameters was used, which allowed the analysis of relevance of SNPs for asthma and multiple targets. These analyses suggested that SNPs in the AHNAK and MS4A2 genes were indirectly associated with asthma. This paper indicates that BN-BMLA explores the relevant factors more comprehensively than traditional statistical methods and extends the scope of strong relevance based methods to include partial relevance, global characterization of relevance and multi-target relevance. PMID:22432035
Uysal, Hakan; Kurtoglu, Cem; Gurbuz, Riza; Tutuncu, Naki
2005-03-01
The Cresco-Ti System uses a laser-welded process that provides an efficient technique to achieve passive fit frameworks. However, mechanical behavior of the laser-welded joint under biomechanical stress factors has not been demonstrated. This study describes the effect of Cresco-Ti laser-welding conditions on the material properties of the welded specimen and analyzes stresses on the weld joint through 3-dimensional finite element models (3-D FEM) of implant-supported fixed dentures with cantilever extensions and fixed partial denture designs. Twenty Grade III (ASTM B348) commercially pure titanium specimens were machine-milled to the dimensions described in the EN10002-1 tensile test standard and divided into test (n = 10) and control (n = 10) groups. The test specimens were sectioned and laser-welded. All specimens were subjected to tensile testing to determine yield strength (YS), ultimate tensile strength (UTS), and percent elongation (PE). The Knoop micro-indentation test was performed to determine the hardness of all specimens. On welded specimens, the hardness test was performed at the welded surface. Data were analyzed with the Mann-Whitney U test and Student's t test (alpha=.05). Fracture surfaces were examined by scanning electron microscopy to characterize the mode of fracture and identify defects due to welding. Three-dimensional FEMs were created that simulated a fixed denture with cantilever extensions supported by 5 implants (M1) and a fixed partial denture supported by 2 implants (M2), 1 of which was angled 30 degrees mesio-axially. An oblique load of 400 N with 15 degrees lingual-axial inclinations was applied to both models at various locations. Test specimens fractured between the weld and the parent material. No porosities were observed on the fractured surfaces. Mean values for YS, UTS, PE, and Knoop hardness were 428 +/- 88 MPa, 574 +/- 113 MPa, 11.2 +/- 0.4%, 270 +/- 17 KHN, respectively, for the control group and 642 +/- 2 MPa, 772 +/- 72 MPa, 4.8 +/- 0.7%, 353 +/- 23 KHN, respectively, for the test group. The differences between the groups were significant for all mechanical properties ( P <.05). For both models, the FEA revealed that maximum principal stresses were concentrated at the framework-weld junction but did not exceed the UTS of the weld joint. Within the constraints of the finite element models, mechanical failure of the welded joint between the support and the framework may not be expected under biomechanical conditions simulated in this study.
Van Strien, Jan W; Isbell, Lynne A
2017-04-07
Studies of event-related potentials in humans have established larger early posterior negativity (EPN) in response to pictures depicting snakes than to pictures depicting other creatures. Ethological research has recently shown that macaques and wild vervet monkeys respond strongly to partially exposed snake models and scale patterns on the snake skin. Here, we examined whether snake skin patterns and partially exposed snakes elicit a larger EPN in humans. In Task 1, we employed pictures with close-ups of snake skins, lizard skins, and bird plumage. In task 2, we employed pictures of partially exposed snakes, lizards, and birds. Participants watched a random rapid serial visual presentation of these pictures. The EPN was scored as the mean activity (225-300 ms after picture onset) at occipital and parieto-occipital electrodes. Consistent with previous studies, and with the Snake Detection Theory, the EPN was significantly larger for snake skin pictures than for lizard skin and bird plumage pictures, and for lizard skin pictures than for bird plumage pictures. Likewise, the EPN was larger for partially exposed snakes than for partially exposed lizards and birds. The results suggest that the EPN snake effect is partly driven by snake skin scale patterns which are otherwise rare in nature.
Van Strien, Jan W.; Isbell, Lynne A.
2017-01-01
Studies of event-related potentials in humans have established larger early posterior negativity (EPN) in response to pictures depicting snakes than to pictures depicting other creatures. Ethological research has recently shown that macaques and wild vervet monkeys respond strongly to partially exposed snake models and scale patterns on the snake skin. Here, we examined whether snake skin patterns and partially exposed snakes elicit a larger EPN in humans. In Task 1, we employed pictures with close-ups of snake skins, lizard skins, and bird plumage. In task 2, we employed pictures of partially exposed snakes, lizards, and birds. Participants watched a random rapid serial visual presentation of these pictures. The EPN was scored as the mean activity (225–300 ms after picture onset) at occipital and parieto-occipital electrodes. Consistent with previous studies, and with the Snake Detection Theory, the EPN was significantly larger for snake skin pictures than for lizard skin and bird plumage pictures, and for lizard skin pictures than for bird plumage pictures. Likewise, the EPN was larger for partially exposed snakes than for partially exposed lizards and birds. The results suggest that the EPN snake effect is partly driven by snake skin scale patterns which are otherwise rare in nature. PMID:28387376
METHOD FOR PRODUCING ISOTOPIC METHANES AND PARTIALLY HALOGENATED DERIVATIVES THEROF
Frazer, J.W.
1959-08-18
A method is given for producing isotopic methanes and/ or partially halogenated derivatives. Lithium hydride, deuteride, or tritide is reacted with a halogenated methane or with a halogenated methane in combination with free halogen. The process is conveniently carried out by passing a halogenated methane preferably at low pressures or in an admixture with an inert gas through a fixed bed of finely divided lithium hydride heated initially to temperatures of 100 to 200 deg C depending upon the halogenated methane used.
Vetter, Jan M; Holtz, Carsten; Vossmerbaeumer, Urs; Pfeiffer, Norbert
2012-03-01
To evaluate the irregularity of the posterior corneal surface and intrastromal dissection during the preparation of donor tissue for Descemet stripping automated endothelial keratoplasty (DSAEK) using a curved interface femtosecond laser and microkeratome. Sixteen human donor corneas unsuitable for transplantation were divided into two groups: a femtosecond (FS) laser group (n=7) using the VisuMax femtosecond laser (Carl Zeiss Meditec) and a microkeratome group (n=9) using the Amadeus II microkeratome (Ziemer Ophthalmic Group). The corneas were fixed on artificial anterior chambers. Horizontal cross-sections were obtained using spectral-domain optical coherence tomography prior to applanation, during applanation, as well as during and after intrastromal dissection at 450-μm corneal depth. The posterior surface and the dissection line were evaluated for irregularity by fitting a second-order polynomial curve using regression analysis and obtaining the root-mean-square error (RMSE). Groups were compared using analysis of variance. The RMSE of the posterior surface prior to applanation was 9.7 ± 3.1 μm in the FS laser group and 10.2 ± 2.3 μm in the microkeratome group. The RMSE increased to 50.7 ± 9.4 μm and 20.9 ± 6.1 μm during applanation and decreased again to 10.6 ± 1.4 μm and 8.1 ± 1.8 μm after applanation in the FS laser and microkeratome groups, respectively. The RMSE of the intrastromal cut was 19.5 ± 5.7 μm in the FS laser group and 7.7 ± 3.0 μm in the microkeratome group (P<.001). Our results show significantly greater irregularity with the curved interface femtosecond laser-assisted cleavage compared to microkeratome-assisted corneal dissection, possibly due to applanation-derived deformation of the posterior cornea. Copyright 2012, SLACK Incorporated.
Suh, Seung Woo; Modi, Hitesh N; Yang, Jaehyuk; Song, Hae-Ryong; Jang, Ki-Mo
2009-05-20
Prospective study. To determine the effectiveness and correction with posterior multilevel vertebral osteotomy in severe and rigid curves without anterior release. For the correction of severe and rigid scoliotic curve, anterior-posterior combined or posterior vertebral column resection (PVCR) procedures are used. Anterior procedure might compromise pulmonary functions, and PVCR might carry risk of neurologic injuries. Therefore, authors developed a new technique, which reduces both. Thirteen neuromuscular patients (7 cerebral palsy, 2 Duchenne muscular dystrophy, and 4 spinal muscular atrophy) who had rigid curve >100 degrees were prospectively selected. All were operated with posterior-only approach using pedicle screw construct. To achieve desired correction, posterior multilevel vertebral osteotomies were performed at 3 to 5 levels (apex, and 1-2 levels above and below apex) through partial laminotomy sites connecting from concave to convex side, just above the pedicle; and repeated cantilever manipulation was applied over temporary short-segment fixation, above and below the apex, on convex side. On concave side, rod was assembled with screws and rod-derotation maneuver was performed. Finally, short-segment fixation on convex side was replaced with full-length construct. Intraoperative MEP monitoring was applied in all. Mean age was 21 years and average follow-up was 25 months. Average preoperative flexibility was 20.3% (24.1 degrees). Average Cobb's angle, pelvic obliquity, and apical rotation were 118.2 degrees, 16.7 degrees, and 57 degrees preoperatively, respectively, and 48.8 degrees, 8 degrees, and 43 degrees after surgery showing significant correction of 59.4%, 46.1%, and 24.5%. Average number of osteotomy level was 4.2 and average blood loss was 3356 +/- 884 mL. Mean operation time was 330 +/- 46 minutes. None of the patient required postoperative ventilator support or displayed any signs of neurologic or vascular injuries during or after the operation. This technique should be recommended because (1) it provides release of anterior column without anterior approach and (2) our results supports its superiority as a technique.
Tymko, Michael M; Rickards, Caroline A; Skow, Rachel J; Ingram-Cotton, Nathan C; Howatt, Michael K; Day, Trevor A
2016-09-01
Steady-state tilt has no effect on cerebrovascular reactivity to increases in the partial pressure of end-tidal carbon dioxide (PETCO2). However, the anterior and posterior cerebral circulations may respond differently to a variety of stimuli that alter central blood volume, including lower body negative pressure (LBNP). Little is known about the superimposed effects of head-up tilt (HUT; decreased central blood volume and intracranial pressure) and head-down tilt (HDT; increased central blood volume and intracranial pressure), and LBNP on cerebral blood flow (CBF) responses. We hypothesized that (a) cerebral blood velocity (CBV; an index of CBF) responses during LBNP would not change with HUT and HDT, and (b) CBV in the anterior cerebral circulation would decrease to a greater extent compared to posterior CBV during LBNP when controlling PETCO2 In 13 male participants, we measured CBV in the anterior (middle cerebral artery, MCAv) and posterior (posterior cerebral artery, PCAv) cerebral circulations using transcranial Doppler ultrasound during LBNP stress (-50 mmHg) in three body positions (45°HUT, supine, 45°HDT). PETCO2 was measured continuously and maintained at constant levels during LBNP through coached breathing. Our main findings were that (a) steady-state tilt had no effect on CBV responses during LBNP in both the MCA (P = 0.077) and PCA (P = 0.583), and (b) despite controlling for PETCO2, both the MCAv and PCAv decreased by the same magnitude during LBNP in HUT (P = 0.348), supine (P = 0.694), and HDT (P = 0.407). Here, we demonstrate that there are no differences in anterior and posterior circulations in response to LBNP in different body positions. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.
Type and location of placenta previa affect preterm delivery risk related to antepartum hemorrhage.
Sekiguchi, Atsuko; Nakai, Akihito; Kawabata, Ikuno; Hayashi, Masako; Takeshita, Toshiyuki
2013-01-01
To evaluate whether type and location of placenta previa affect risk of antepartum hemorrhage-related preterm delivery. We retrospectively studied 162 women with singleton pregnancies presenting placenta previa. Through observation using transvaginal ultrasound the women were categorized into complete or incomplete placenta previa, and then assigned to anterior and posterior groups. Complete placenta previa was defined as a placenta that completely covered the internal cervical os, with the placental margin >2 cm from the os. Incomplete placenta previa comprised marginal placenta previa whose margin adjacent to the internal os and partial placenta previa which covered the os but the margin situated within 2 cm of the os. Maternal characteristics and perinatal outcomes in complete and incomplete placenta previa were compared, and the differences between the anterior and the posterior groups were evaluated. Antepartum hemorrhage was more prevalent in women with complete placenta previa than in those with incomplete placenta previa (59.1% versus 17.6%), resulting in the higher incidence of preterm delivery in women with complete than in those with incomplete placenta previa [45.1% versus 8.8%; odds ratio (OR) 8.51; 95% confidence interval (CI) 3.59-20.18; p < 0.001]. In complete placenta previa, incidence of antepartum hemorrhage did not significantly differ between the anterior and the posterior groups. However, gestational age at bleeding onset was lower in the anterior group than in the posterior group, and the incidence of preterm delivery was higher in the anterior group than in the posterior group (76.2% versus 32.0%; OR 6.8; 95% CI 2.12-21.84; p = 0.002). In incomplete placenta previa, gestational age at delivery did not significantly differ between the anterior and posterior groups. Obstetricians should be aware of the increased risk of preterm delivery related to antepartum hemorrhage in women with complete placenta previa, particularly when the placenta is located on the anterior wall.
Type and Location of Placenta Previa Affect Preterm Delivery Risk Related to Antepartum Hemorrhage
Sekiguchi, Atsuko; Nakai, Akihito; Kawabata, Ikuno; Hayashi, Masako; Takeshita, Toshiyuki
2013-01-01
Purpose: To evaluate whether type and location of placenta previa affect risk of antepartum hemorrhage-related preterm delivery. Methods: We retrospectively studied 162 women with singleton pregnancies presenting placenta previa. Through observation using transvaginal ultrasound the women were categorized into complete or incomplete placenta previa, and then assigned to anterior and posterior groups. Complete placenta previa was defined as a placenta that completely covered the internal cervical os, with the placental margin >2 cm from the os. Incomplete placenta previa comprised marginal placenta previa whose margin adjacent to the internal os and partial placenta previa which covered the os but the margin situated within 2 cm of the os. Maternal characteristics and perinatal outcomes in complete and incomplete placenta previa were compared, and the differences between the anterior and the posterior groups were evaluated. Results: Antepartum hemorrhage was more prevalent in women with complete placenta previa than in those with incomplete placenta previa (59.1% versus 17.6%), resulting in the higher incidence of preterm delivery in women with complete than in those with incomplete placenta previa [45.1% versus 8.8%; odds ratio (OR) 8.51; 95% confidence interval (CI) 3.59-20.18; p < 0.001]. In complete placenta previa, incidence of antepartum hemorrhage did not significantly differ between the anterior and the posterior groups. However, gestational age at bleeding onset was lower in the anterior group than in the posterior group, and the incidence of preterm delivery was higher in the anterior group than in the posterior group (76.2% versus 32.0%; OR 6.8; 95% CI 2.12-21.84; p = 0.002). In incomplete placenta previa, gestational age at delivery did not significantly differ between the anterior and posterior groups. Conclusion: Obstetricians should be aware of the increased risk of preterm delivery related to antepartum hemorrhage in women with complete placenta previa, particularly when the placenta is located on the anterior wall. PMID:24151440
Lookback Option Pricing with Fixed Proportional Transaction Costs under Fractional Brownian Motion.
Sun, Jiao-Jiao; Zhou, Shengwu; Zhang, Yan; Han, Miao; Wang, Fei
2014-01-01
The pricing problem of lookback option with a fixed proportion of transaction costs is investigated when the underlying asset price follows a fractional Brownian motion process. Firstly, using Leland's hedging method a partial differential equation satisfied by the value of the lookback option is derived. Then we obtain its numerical solution by constructing a Crank-Nicolson format. Finally, the effectiveness of the proposed form is verified through a numerical example. Meanwhile, the impact of transaction cost rate and volatility on lookback option value is discussed.
Lookback Option Pricing with Fixed Proportional Transaction Costs under Fractional Brownian Motion
Sun, Jiao-Jiao; Zhou, Shengwu; Zhang, Yan; Han, Miao; Wang, Fei
2014-01-01
The pricing problem of lookback option with a fixed proportion of transaction costs is investigated when the underlying asset price follows a fractional Brownian motion process. Firstly, using Leland's hedging method a partial differential equation satisfied by the value of the lookback option is derived. Then we obtain its numerical solution by constructing a Crank-Nicolson format. Finally, the effectiveness of the proposed form is verified through a numerical example. Meanwhile, the impact of transaction cost rate and volatility on lookback option value is discussed. PMID:27433525
Tunable cavity resonator including a plurality of MEMS beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peroulis, Dimitrios; Fruehling, Adam; Small, Joshua Azariah
A tunable cavity resonator includes a substrate, a cap structure, and a tuning assembly. The cap structure extends from the substrate, and at least one of the substrate and the cap structure defines a resonator cavity. The tuning assembly is positioned at least partially within the resonator cavity. The tuning assembly includes a plurality of fixed-fixed MEMS beams configured for controllable movement relative to the substrate between an activated position and a deactivated position in order to tune a resonant frequency of the tunable cavity resonator.
Angulated Implants for Fabrication of Implant Supported Fixed Partial Denture in the Maxilla
Egbert, Nicholas; Ahuja, Swati; Selecman, Audrey; Wicks, Russell
2017-01-01
Until recently, angled abutments have been the only solution to correcting the trajectory of the emergence profile of labially inclined implants in the maxilla. However, the clinical implications of angled abutments reveal several shortcomings. Newly designed angulated implants with a 12-degree restorative platform angulation are an alternative to angled abutments. The purpose of this article was to report a case utilizing new angulated implants (Co-axis, Keystone dental, Burlington, MA, USA) in the premaxilla thereby facilitating fabrication of a multi-unit implant retained fixed dental prosthesis. PMID:29201975
[Particular posteromedial and posterolateral approaches for the treatment of tibial head fractures].
Lobenhoffer, P; Gerich, T; Bertram, T; Lattermann, C; Pohlemann, T; Tscheme, H
1997-12-01
Tibial plateau fractures with depression of posterior aspects of the proximal tibia cause significant therapeutic problems. Posterior fractures on the medial side are mainly highly instable fracture-dislocations (Moore type I). Posterolateral fractures usually cause massive depression and destruction of the chondral surface. Surgical exposure of these fractures from anterior requires major soft tissue dissection and has a significant complication rate. However, incomplete restoration of the joint surface results in chronic postero-inferior joint subluxation, osteoarthritis and pain. We present new specific approaches for posterior fracture types avoiding large skin incisions, but allowing for atraumatic exposure, reduction and fixation. Posteromedial fracture-dislocations are exposed by a direct posteromedial skin incision and a deep incision between medial collateral ligament and posterior oblique ligament. The posteromedial pillar and the posterior flare of the proximal tibia are visualized. The inferior extent of the joint fragment can be reduced by indirect techniques or direct manipulation of the fragment. Fixation is achieved with subchondral lag screws and an anti-glide plate at the tip of the fragment. Posterolateral fractures are exposed by a transfibular approach: the skin is incised laterally, the peroneal nerve is dissected free. The fibula neck is osteotomized, the tibiofibular syndesmosis is divided and the fibula neck is reflected upwards in one layer with the meniscotibial ligament and the iliotibial tract attachment. Reflexion of the fibula head relaxes the lateral collateral ligament, allows for lateral joint opening and internal rotation of the tibia and thus exposes the posterolateral and posterior aspect of the tibial plateau. Fixation and buttressing on the posterolateral side can be achieved easily with this approach. In closure, the fibula head is fixed back with a lag screw or a tension-band system. These two exposures can be combined in bicondylar posterior fracture situations. 168 cases with tibial plateau fractures had ORIF in the authors' institution from 1988 to 1994. 26 of these patients had a total of 29 posterior exposures to treat their fractures (9 posteromedial, 12 posterolateral, 3 combined posteromedial/posterolateral and 2 posterior/anterior exposures). No specific complications occurred related to these exposures, i.e. no skin slough, no infection, no nerve palsy. The mean duration of follow-up was 4 years. Twenty-one cases healed uneventfully: 12 were excellent in Rasmussen's clinical score, 8 were good and 1 was fair. Seven patients were excellent in the radiological score, 13 good and 1 fair. Five of the 26 cases had revision surgery: 3 patients developed valgus or retrocurvatum deformity and were successfully treated by an osteotomy. They obtained a good result at follow-up. Two fractures in elderly patients were revised to an endoprosthesis.
Liu, Tie-long; Yan, Wang-jun; Han, Yu; Ye, Xiao-jian; Jia, Lian-shun; Li, Jia-shun; Yuan, Wen
2010-05-01
To compare the biomechanical performances of different wires and cable fixation devices in posterior instrumentation for atlantoaxial instability, and test the effect of different fixation strengths and fixation approaches on the surgical outcomes. Six specimens of the atlantoaxial complex (C0-C3) were used to establish models of the normal complex, unstable complex (type II odontoid fracture) and fixed complex. On the wd-5 mechanical testing machine, the parameters including the strength and rigidity of anti-rotation, change and strength of stress, and stability were measured for the normal complex, atlantoaxial instability complex, the new type titanium cable fixation system, Atlas titanium cable, Songer titanium cable, and stainless wire. The strength and rigidity of anti-rotation, change and strength of stress, stability of flexion, extension and lateral bending of the unstable atlantoaxial complex fixed by the new double locking titanium cable fixation system were superior to those of the Songer or Atlas titanium cable (P<0.05) and medical stainless wire (P<0.05). Simultaneous cable fastening on both sides resulted in better fixation effect than successive cable fastening (P<0.05). Better fixation effect was achieved by fastening the specimen following a rest (P<0.05). The fixation effects can be enhanced by increased fastening strengths. The new type double locking titanium cable fixation system has better biomechanical performance than the conventional Songer and Atlas titanium cables. Fastening the unstable specimens after a rest following simultaneous fastening of the specimen on both sides produces better fixation effect.
Sparto, Patrick J.; Furman, Joseph M.; Redfern, Mark S.
2014-01-01
Background The purpose of this study was to examine how older adults with vestibular impairment use sensory feedback for postural control. Methods Nine older adult subjects with unilateral vestibular hypofunction (UVH, mean age 69 y) and 14 older (mean age 70 y) and 8 young adult controls (CON, mean age 28 y) viewed full-field optic flow scenes while standing on a fixed or sway-referenced support surface. The subjects with UVH had 100% caloric asymmetry. Optic flow consisted of sinusoidal anterior-posterior movement of the visual surround at three frequencies and three amplitudes of stimulation. The anterior-posterior head sway was measured. The number of head sway responses that were coupled to the optic flow and magnitude of head sway during optic flow relative to during quiet stance on fixed floor was quantified. Results The number of trials in which the head sway response was significantly coupled to the optic flow was significantly greater in the Older UVH and Older CON subjects compared with the Young CON subjects. Furthermore, the magnitude of head sway was two to three times greater in Older UVH and CON compared with Young CON subjects. There was no difference in coupling or magnitude of head sway between Older UVH and Older CON subjects. The amplitude of sway was also dependent on the amount of surface support, stimulus frequency, and stimulus amplitude. Conclusions Older adults with unilateral vestibular hypofunction who are able to effectively compensate show no difference in postural responses elicited by optic flow compared with age-matched controls. PMID:17312341
Bayesian Model Selection in Geophysics: The evidence
NASA Astrophysics Data System (ADS)
Vrugt, J. A.
2016-12-01
Bayesian inference has found widespread application and use in science and engineering to reconcile Earth system models with data, including prediction in space (interpolation), prediction in time (forecasting), assimilation of observations and deterministic/stochastic model output, and inference of the model parameters. Per Bayes theorem, the posterior probability, , P(H|D), of a hypothesis, H, given the data D, is equivalent to the product of its prior probability, P(H), and likelihood, L(H|D), divided by a normalization constant, P(D). In geophysics, the hypothesis, H, often constitutes a description (parameterization) of the subsurface for some entity of interest (e.g. porosity, moisture content). The normalization constant, P(D), is not required for inference of the subsurface structure, yet of great value for model selection. Unfortunately, it is not particularly easy to estimate P(D) in practice. Here, I will introduce the various building blocks of a general purpose method which provides robust and unbiased estimates of the evidence, P(D). This method uses multi-dimensional numerical integration of the posterior (parameter) distribution. I will then illustrate this new estimator by application to three competing subsurface models (hypothesis) using GPR travel time data from the South Oyster Bacterial Transport Site, in Virginia, USA. The three subsurface models differ in their treatment of the porosity distribution and use (a) horizontal layering with fixed layer thicknesses, (b) vertical layering with fixed layer thicknesses and (c) a multi-Gaussian field. The results of the new estimator are compared against the brute force Monte Carlo method, and the Laplace-Metropolis method.
On occlusal forces in dentitions with implant-supported fixed cantilever prostheses.
Falk, H
1990-01-01
The main aims of this thesis were (1) to study the functional characteristics of dentitions with mandibular implant-supported fixed cantilever prostheses - IFCP s- occluding with complete dentures, (2) to study in detail the magnitudes and distributions of axially directed closing and chewing forces in such dentitions, (3) to study the influence of number and distribution of occlusal contacts on the magnitude and distribution of closing and chewing forces, (4) to assess the vertical bending moment and the resulting vertical bending stress in the cantilever joints and (5) to find out whether the force distribution over the cantilever beams and the resulting vertical bending stress in the cantilever joint are influenced by the type of prosthetic construction in the opposing jaw. Closing and chewing forces were registered in altogether seventeen subjects by means of miniature strain gauge transducers mounted bilaterally and symmetrically in performed matrices in prosthetic appliances. Four, six or eight transducers, evenly distributed over the tooth-arch, permitted registrations of axially directed occlusal forces in several occluding areas simultaneously. In Papers I-IV, the implant-supported prostheses were installed in the mandible and occluded with complete dentures. In Paper V, group A, the fixture-supported prostheses were installed in the maxilla and occluded with tooth-supported fixed partial dentures whereas in group B, the arrangements were analogous to those in Papers I-IV. All subjects exhibited a rhythmic chewing pattern and preferred one side for chewing although both sides were used. Most chewing sequences were terminated with swallowing with occlusal force development. The mean total forces acting over the tooth-arch varied somewhat between groups and occlusal arrangements but averaged 350 and 170 N for closing and chewing respectively. Closing and chewing forces increased distally along the cantilever beams when occluding with complete dentures and decreased distally when occluding with fixed partial dentures. The distally increasing force distribution pattern could be altered to a distally decreasing force distribution pattern by infraoccluding the second cantilever unit by as little as 100 microns. Calculated vertical bending moments and stresses in the cantilever joints of the preferred chewing sides created by closing and chewing forces were larger in dentitions where the IFCP occluded with a complete denture than in dentitions where the IFCP occluded with a tooth-supported fixed partial denture.
Periconal arterial anastomotic circle and posterior lumbosacral watershed zone of the spinal cord.
Gailloud, Philippe; Gregg, Lydia; Galan, Peter; Becker, Daniel; Pardo, Carlos
2015-11-01
The existence of spinal cord watershed territories was suggested in the 1950s. Segmental infarcts within the junctional territories of adjacent radiculomedullary contributors and isolated spinal gray matter ischemia constitute two well-recognized types of watershed injury. This report describes the existence of another watershed territory related to the particular configuration of the spinal vasculature in the region of the conus medullaris. The anatomical bases underlying the concept of a posterior lumbosacral watershed zone are demonstrated with angiographic images obtained in a 16-year-old child. The clinical importance of this watershed zone is illustrated with MRI and angiographic data of three patients with a conus medullaris infarction. In all three cases of spinal ischemia an intersegmental artery providing a significant radiculomedullary contribution for the lower cord was compromised by a compressive mechanism responsible for decreased spinal cord perfusion (diaphragmatic crus syndrome in two cases, disk herniation in one). The ischemic injury, located at the junction of the anterior and posterior spinal artery territories along the dorsal aspect of the conus medullaris, was consistent with a watershed mechanism. This zone is at risk because of the caudocranial direction of flow within the most caudal segment of the posterior spinal arterial network which, from a functional standpoint, depends on the anterior spinal artery. The posterior thoracolumbar watershed zone of the spinal cord represents an area at increased risk of ischemic injury, particularly in the context of partial flow impairment related to arterial compression mechanisms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
NASA Astrophysics Data System (ADS)
Cui, Tiangang; Marzouk, Youssef; Willcox, Karen
2016-06-01
Two major bottlenecks to the solution of large-scale Bayesian inverse problems are the scaling of posterior sampling algorithms to high-dimensional parameter spaces and the computational cost of forward model evaluations. Yet incomplete or noisy data, the state variation and parameter dependence of the forward model, and correlations in the prior collectively provide useful structure that can be exploited for dimension reduction in this setting-both in the parameter space of the inverse problem and in the state space of the forward model. To this end, we show how to jointly construct low-dimensional subspaces of the parameter space and the state space in order to accelerate the Bayesian solution of the inverse problem. As a byproduct of state dimension reduction, we also show how to identify low-dimensional subspaces of the data in problems with high-dimensional observations. These subspaces enable approximation of the posterior as a product of two factors: (i) a projection of the posterior onto a low-dimensional parameter subspace, wherein the original likelihood is replaced by an approximation involving a reduced model; and (ii) the marginal prior distribution on the high-dimensional complement of the parameter subspace. We present and compare several strategies for constructing these subspaces using only a limited number of forward and adjoint model simulations. The resulting posterior approximations can rapidly be characterized using standard sampling techniques, e.g., Markov chain Monte Carlo. Two numerical examples demonstrate the accuracy and efficiency of our approach: inversion of an integral equation in atmospheric remote sensing, where the data dimension is very high; and the inference of a heterogeneous transmissivity field in a groundwater system, which involves a partial differential equation forward model with high dimensional state and parameters.
Kim, Hae-Young; Yang, Jin-Yong; Chung, Bo-Yoon; Kim, Jeong Chan; Yeo, In-Sung
2013-04-01
The aim of this study was to measure the peri-implant bone length surrounding implants that penetrate the sinus membrane at the posterior maxilla and to evaluate the survival rate of these implants. Treatment records and orthopantomographs of 39 patients were reviewed and analyzed. The patients had partial edentulism at the posterior maxilla and limited vertical bone height below the maxillary sinus. Implants were inserted into the posterior maxilla, penetrating the sinus membrane. Four months after implant insertion, provisional resin restorations were temporarily cemented to the abutments and used for one month. Then, a final impression was taken at the abutment level, and final cement-retained restorations were delivered with mutually protected occlusion. The complications from the implant surgery were examined, the number of failed implants was counted, and the survival rate was calculated. The peri-implant bone lengths were measured using radiographs. The changes in initial and final peri-implant bone lengths were statistically analyzed. Nasal bleeding occurred after implant surgery in three patients. No other complications were found. There were no failures of the investigated implants, resulting in a survival rate of 100%. Significantly more bone gain around the implants (estimated difference=-0.6 mm, P=0.025) occurred when the initial residual bone height was less than 5 mm compared to the >5 mm groups. No significant change in peri-implant bone length was detected when the initial residual bone height was 5 mm or larger. This study suggests that implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height may be safe and functional.
NASA Astrophysics Data System (ADS)
Lew, E. J.; Butenhoff, C. L.; Karmakar, S.; Rice, A. L.; Khalil, A. K.
2017-12-01
Methane is the second most important greenhouse gas after carbon dioxide. In efforts to control emissions, a careful examination of the methane budget and source strengths is required. To determine methane surface fluxes, Bayesian methods are often used to provide top-down constraints. Inverse modeling derives unknown fluxes using observed methane concentrations, a chemical transport model (CTM) and prior information. The Bayesian inversion reduces prior flux uncertainties by exploiting information content in the data. While the Bayesian formalism produces internal error estimates of source fluxes, systematic or external errors that arise from user choices in the inversion scheme are often much larger. Here we examine model sensitivity and uncertainty of our inversion under different observation data sets and CTM grid resolution. We compare posterior surface fluxes using the data product GLOBALVIEW-CH4 against the event-level molar mixing ratio data available from NOAA. GLOBALVIEW-CH4 is a collection of CH4 concentration estimates from 221 sites, collected by 12 laboratories, that have been interpolated and extracted to provide weekly records from 1984-2008. Differently, the event-level NOAA data records methane mixing ratios field measurements from 102 sites, containing sampling frequency irregularities and gaps in time. Furthermore, the sampling platform types used by the data sets may influence the posterior flux estimates, namely fixed surface, tower, ship and aircraft sites. To explore the sensitivity of the posterior surface fluxes to the observation network geometry, inversions composed of all sites, only aircraft, only ship, only tower and only fixed surface sites, are performed and compared. Also, we investigate the sensitivity of the error reduction associated with the resolution of the GEOS-Chem simulation (4°×5° vs 2°×2.5°) used to calculate the response matrix. Using a higher resolution grid decreased the model-data error at most sites, thereby increasing the information at that site. These different inversions—event-level and interpolated data, higher and lower resolutions—are compared using an ensemble of descriptive and comparative statistics. Analyzing the sensitivity of the inverse model leads to more accurate estimates of the methane source category uncertainty.
Introduction of a New Locking Nail for Treatment of Intraarticular Calcaneal Fractures.
Zwipp, Hans; Paša, Libor; Žilka, Luboš; Amlang, Michael; Rammelt, Stefan; Pompach, Martin
2016-03-01
To reduce the complication rate associated with open reduction and internal fixation of displaced intraarticular calcaneal fractures through extensile approaches, a locking nail system (C-Nail) was developed for internal fixation. Prospective case-control study. Two level I trauma centers (university hospital) and 1 large regional hospital in the Czech Republic and Germany. One hundred three patients (89 male and 14 female; mean age, 45.6 years) with 106 calcaneal fractures were treated between February 2011 and October 2013. In all 106 cases, the stainless steel C-Nail with a length of 65 mm, a diameter of 8 mm, and 7 locking options was used for internal fixation. Previous reduction of the posterior facet was performed in 15 cases percutaneously, assisted by arthroscopy and fluoroscopy, and in 91 cases by a sinus tarsi approach. The reduced joint surface was fixed by 1 or 2 compression screws. All other fragments were fixed after reduction and temporary K-wire fixation with the C-Nail introduced percutaneously through the tuberosity and 5 to 6 interlocking screws. The latter were introduced into the sustentacular, the tuberosity, and the anterior process fragments with an aiming device consisting of 3 arms. Patients were assessed for complications, restoration of Böhler angle, posterior facet reduction with postoperative computed tomography, and weight-bearing radiographs at 6 months. Functional outcome was assessed using the American Orthopaedic Foot & Ankle Society (AOFAS) ankle/hindfoot scale after 6 and 12 months for all patients. Wound edge necrosis was seen in 2 cases (1.9%), and soft tissue infection was observed in 1 case (0.9%). Böhler angle improved from 7.3 degree preoperatively to 28.7 degree at 6 months. The posterior facet step-off was reduced from 5.3 mm preoperatively to 0.7 mm postoperatively. The average AOFAS score averaged 89.5 at 6-month and 92.6 at 12-month follow-up. The C-Nail is a new locking system for treatment of displaced intraarticular calcaneal fractures combining a primary stability with reduced soft tissue complications. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Simulation of Anterior Cruciate Ligament Deficiency in a Musculoskeletal Model with Anatomical Knees
Guess, Trent M; Stylianou, Antonis
2012-01-01
Abnormal knee kinematics and meniscus injury resulting from anterior cruciate ligament (ACL) deficiency are often implicated in joint degeneration even though changes in tibio-femoral contact location after injury are small, typically only a few millimeters. Ligament reconstruction surgery does not significantly reduce the incidence of early onset osteoarthritis. Increased knowledge of knee contact mechanics would increase our understanding of the effects of ACL injury and help guide ACL reconstruction methods. Presented here is a cadaver specific computational knee model combined with a body-level musculoskeletal model from a subject of similar height and weight as the cadaver donor. The knee model was developed in the multi-body framework and includes representation of the menisci. Experimental body-level measurements provided input to the musculoskeletal model. The location of tibio-menisco-femoral contact as well as contact pressures were compared for models with an intact ACL, partial ACL transection (posterolateral bundle transection), and full ACL transection during a muscle driven forward dynamics simulation of a dual limb squat. During the squat, small changes in femur motion relative to the tibia for both partial and full ACL transection push the lateral meniscus in the posterior direction at extension. The central-anterior region of the lateral meniscus then becomes “wedged” between the tibia and femur during knee flexion. This “wedging” effect does not occur for the intact knee. Peak contact pressure and contact locations are similar for the partial tear and complete ACL transection during the deep flexion portion of the squat, particularly on the lateral side. The tibio-femoral contact location on the tibia plateau shifts slightly to the posterior and lateral direction with ACL transection. PMID:22470411
Bakeman, E M; Rego, N; Chaiyabutr, Y; Kois, J C
2015-01-01
This study evaluated the influence of ceramic thickness and ceramic materials on fracture resistance of posterior partial coverage ceramic restorations. Forty extracted molars were allocated into four groups (n=10) to test for two variables: 1) the thickness of ceramic (1 mm or 2 mm) and 2) the ceramic materials (a lithium disilicate glass-ceramic [IPS e.max] or leucite-reinforced glass ceramic [IPS Empress]). All ceramic restorations were luted with resin cement (Variolink II) on the prepared teeth. These luted specimens were loaded to failure in a universal testing machine, in the compression mode, with a crosshead speed of 1.0 mm/min. The data were analyzed using two-way analysis of variance and the Tukey Honestly Significantly Different multiple comparison test (α =0.05). The fracture resistance revealed a significant effect for materials (p<0.001); however, the thickness of ceramic was not significant (p=0.074), and the interaction between the thickness of ceramic and the materials was not significant (p=0.406). Mean (standard deviation) fracture resistance values were as follows: a 2-mm thickness of a lithium disilicate bonded to tooth structure (2505 [401] N) revealed a significantly higher fracture resistance than did a 1-mm thickness of leucite-reinforced (1569 [452] N) and a 2-mm thickness of leucite-reinforced ceramic bonded to tooth structure (1716 [436] N) (p<0.05). There was no significant difference in fracture resistance values between a lithium disilicate ceramic at 1-mm thickness (2105 [567] N) and at 2-mm thickness. Using a lithium disilicate glass ceramic for partial coverage restoration significantly improved fracture resistance compared to using a leucite-reinforced glass ceramic. The thickness of ceramic had no significant effect on fracture resistance when the ceramics were bonded to the underlying tooth structure.
An approach for fixed coefficient RNS-based FIR filter
NASA Astrophysics Data System (ADS)
Srinivasa Reddy, Kotha; Sahoo, Subhendu Kumar
2017-08-01
In this work, an efficient new modular multiplication method for {2k-1, 2k, 2k+1-1} moduli set is proposed to implement a residue number system (RNS)-based fixed coefficient finite impulse response filter. The new multiplication approach reduces the number of partial products by using pre-loaded product block. The reduction in partial products with the proposed modular multiplication improves the clock frequency and reduces the area and power as compared with the conventional modular multiplication. Further, the present approach eliminates a binary number to residue number converter circuit, which is usually needed at the front end of RNS-based system. In this work, two fixed coefficient filter architectures with the new modular multiplication approach are proposed. The filters are implemented using Verilog hardware description language. The United Microelectronics Corporation 90 nm technology library has been used for synthesis and the results area, power and delay are obtained with the help of Cadence register transfer level compiler. The power delay product (PDP) is also considered for performance comparison among the proposed filters. One of the proposed architecture is found to improve PDP gain by 60.83% as compared with the filter implemented with conventional modular multiplier. The filters functionality is validated with the help of Altera DSP Builder.
Heesterbeek, P J C; van Houten, A H; Klenk, J S; Eijer, H; Christen, B; Wymenga, A B; Schuster, A J
2018-05-01
Only few long-term data on ligament-balanced cruciate-retaining total knee arthroplasty (CR TKA) are currently available. Either a mobile- or fixed-bearing insert can be chosen, which showed good mid-term outcome and few complications and revisions. This multi-centre retrospective cross-sectional cohort study investigated the 12-year results of primary TKA using a balancing gap technique and compared survival and clinical outcome between fixed and mobile inserts. In this retrospective cross-sectional cohort study, 557 cases of three clinics (2 Swiss, 1 Dutch) operated between 1998 and 2003 with the first series of a TKA implanted with a balanced gap technique (433 (77.7%) fixed, 124 (22.3%) mobile (anterior-posterior gliding (7-9 mm) and rotational (15°) degrees of freedom) inserts) were included for survival analysis (Kaplan-Meier, by insert type). At the 12-year follow-up (FU) examination of 189 cases, range of motion, knee society score (KSS), numeric rating scale (NRS) for pain and satisfaction were determined and radiographs were evaluated by median tests, by insert type. Of 521 cases available for analysis, 28 (5.4%; 11 fixed, 17 mobile bearing) were revised. Mean cumulative survival after 12.4 years was 97.0% (95% CI 94.7-98.4) for fixed bearings and 85.4% (95% CI 77.5-90.7) after 12.2 years for mobile bearings, p < 0.0001. Patients' mean age at 11.0 years FU (n = 189) was 78.0 (range 54.5-97.3) years. Mean total KSS was 157.8 (24-200) points, and mean passive flexion was 114° (45-150); no clinical score differed significantly between fixed and mobile bearings. This study showed a superior survival for fixed bearing compared with mobile bearing in a CR TKA using a ligament-balanced technique after more than 12 years. Clinical outcomes are excellent to good after long-term follow-up, and similar for fixed and mobile bearing. Therapeutic studies-retrospective cohort study, Level III.
ERIC Educational Resources Information Center
Rathje, William L.
1989-01-01
Presents a historical perspective of garbage management, including an exploration of what is cited as myths about garbage that guide our thinking in dealing with solid waste disposal problems. A partial list of topics includes quantity of garbage, landfills, toxic wastes, technological fixes, economics, source reduction, resource recovery,…
Juodzbalys, Gintaras
2015-01-01
ABSTRACT Objectives The purpose of this first part of a two-part series was to review the literature concerning the indications, contraindications, advantages, disadvantages and surgical techniques of the lateralization and transposition of the inferior alveolar nerve, followed by the placement of an implant in an edentulous atrophic posterior mandible. Material and Methods A comprehensive review of the current literature was conducted according to the PRISMA guidelines by accessing the NCBI PubMed and PMC database, academic sites and books. The articles were searched from January 1997 to July 2014 and comprised English-language articles that included adult patients between 18 and 80 years old with minimal residual bone above the mandibular canal who had undergone inferior alveolar nerve (IAN) repositioning with a minimum 6 months of follow-up. Results A total of 16 studies were included in this review. Nine were related to IAN transposition, 4 to IAN lateralization and 3 to both transposition and lateralization. Implant treatment results and complications were presented. Conclusions Inferior alveolar nerve lateralization and transposition in combination with the installation of dental implants is sometimes the only possible procedure to help patients to obtain a fixed prosthesis, in edentulous atrophic posterior mandibles. With careful pre-operative surgical and prosthetic planning, imaging, and extremely precise surgical technique, this procedure can be successfully used for implant placement in edentulous posterior mandibular segments. PMID:25937873
Chapter 1: Sinonasal anatomy and function.
Dalgorf, Dustin M; Harvey, Richard J
2013-01-01
An understanding of paranasal sinus anatomy based on important fixed landmarks rather than variable anatomy is critical to ensure safe and complete surgery. The concept of the paranasal surgical box defines the anatomic limits of dissection. The boundaries of the surgical box include the middle turbinate medially, orbital wall laterally, and skull base superiorly. The "vertical component" of the surgical box defines the boundaries of the frontal recess and includes the middle turbinate and intersinus septum medially, medial orbital wall and orbital roof laterally, nasofrontal beak anteriorly, and skull base and posterior table of frontal sinus posteriorly. The paranasal sinuses are divided into anterior, posterior, and sphenoidal functional cavities based on their distinct drainage pathways into the nose. The ultimate goal of surgery is to create a functional sinus cavity. Application of the paranasal surgical box and its vertical component enables the surgeon to view the limits of dissection with a single position of the endoscope. This will ensure complete dissection of the functional sinonasal compartments and effectively avoid leaving behind disconnected cells from the surgical cavity, mucocele formation, mucous recirculation, overcome obstructive phenomenon and enable maximal delivery of topical therapy in the post-operative setting. This article reviews the structure and function of the nasal cartilages and turbinates. It also describes the concept of the paranasal surgical box, key anatomical landmarks and limits of dissection. Normal anatomy and common variants of normal anatomy are discussed.
NASA Astrophysics Data System (ADS)
Ferrari, Ulisse
A maximal entropy model provides the least constrained probability distribution that reproduces experimental averages of an observables set. In this work we characterize the learning dynamics that maximizes the log-likelihood in the case of large but finite datasets. We first show how the steepest descent dynamics is not optimal as it is slowed down by the inhomogeneous curvature of the model parameters space. We then provide a way for rectifying this space which relies only on dataset properties and does not require large computational efforts. We conclude by solving the long-time limit of the parameters dynamics including the randomness generated by the systematic use of Gibbs sampling. In this stochastic framework, rather than converging to a fixed point, the dynamics reaches a stationary distribution, which for the rectified dynamics reproduces the posterior distribution of the parameters. We sum up all these insights in a ``rectified'' Data-Driven algorithm that is fast and by sampling from the parameters posterior avoids both under- and over-fitting along all the directions of the parameters space. Through the learning of pairwise Ising models from the recording of a large population of retina neurons, we show how our algorithm outperforms the steepest descent method. This research was supported by a Grant from the Human Brain Project (HBP CLAP).
Lovelock, Paul K; Spurdle, Amanda B; Mok, Myth T S; Farrugia, Daniel J; Lakhani, Sunil R; Healey, Sue; Arnold, Stephen; Buchanan, Daniel; Couch, Fergus J; Henderson, Beric R; Goldgar, David E; Tavtigian, Sean V; Chenevix-Trench, Georgia; Brown, Melissa A
2007-01-01
Many of the DNA sequence variants identified in the breast cancer susceptibility gene BRCA1 remain unclassified in terms of their potential pathogenicity. Both multifactorial likelihood analysis and functional approaches have been proposed as a means to elucidate likely clinical significance of such variants, but analysis of the comparative value of these methods for classifying all sequence variants has been limited. We have compared the results from multifactorial likelihood analysis with those from several functional analyses for the four BRCA1 sequence variants A1708E, G1738R, R1699Q, and A1708V. Our results show that multifactorial likelihood analysis, which incorporates sequence conservation, co-inheritance, segregation, and tumour immunohistochemical analysis, may improve classification of variants. For A1708E, previously shown to be functionally compromised, analysis of oestrogen receptor, cytokeratin 5/6, and cytokeratin 14 tumour expression data significantly strengthened the prediction of pathogenicity, giving a posterior probability of pathogenicity of 99%. For G1738R, shown to be functionally defective in this study, immunohistochemistry analysis confirmed previous findings of inconsistent 'BRCA1-like' phenotypes for the two tumours studied, and the posterior probability for this variant was 96%. The posterior probabilities of R1699Q and A1708V were 54% and 69%, respectively, only moderately suggestive of increased risk. Interestingly, results from functional analyses suggest that both of these variants have only partial functional activity. R1699Q was defective in foci formation in response to DNA damage and displayed intermediate transcriptional transactivation activity but showed no evidence for centrosome amplification. In contrast, A1708V displayed an intermediate transcriptional transactivation activity and a normal foci formation response in response to DNA damage but induced centrosome amplification. These data highlight the need for a range of functional studies to be performed in order to identify variants with partially compromised function. The results also raise the possibility that A1708V and R1699Q may be associated with a low or moderate risk of cancer. While data pooling strategies may provide more information for multifactorial analysis to improve the interpretation of the clinical significance of these variants, it is likely that the development of current multifactorial likelihood approaches and the consideration of alternative statistical approaches will be needed to determine whether these individually rare variants do confer a low or moderate risk of breast cancer.
Athwal, Kiron K; Daou, Hadi El; Kittl, Christoph; Davies, Andrew J; Deehan, David J; Amis, Andrew A
2016-08-01
The aim of this study was to quantify the contributions of medial soft tissues to stability following cruciate-retaining (CR) or posterior-stabilised (PS) total knee arthroplasty (TKA). Using a robotic system, eight cadaveric knees were subjected to ±90-N anterior-posterior force, ±5-Nm internal-external and ±8-Nm varus-valgus torques at various flexion angles. The knees were tested intact and then with CR and PS implants, and successive cuts of the deep and superficial medial collateral ligaments (dMCL, sMCL) and posteromedial capsule (PMC) quantified the percentage contributions of each structure to restraining the applied loads. In implanted knees, the sMCL restrained valgus rotation (62 % across flexion angles), anterior-posterior drawer (24 and 10 %, respectively) and internal-external rotation (22 and 37 %). Changing from CR TKA to PS TKA increased the load on the sMCL when resisting valgus loads. The dMCL restrained 11 % of external and 13 % of valgus rotations, and the PMC was significant at low flexion angles. This work has shown that medial release in the varus knee should be minimised, as it may inadvertently result in a combined laxity pattern. There is increasing interest in preserving constitutional varus in TKA, and this work argues for preservation of the sMCL to afford the surgeon consistent restraint and maintain a balanced knee for the patient.
Embedding the results of focussed Bayesian fusion into a global context
NASA Astrophysics Data System (ADS)
Sander, Jennifer; Heizmann, Michael
2014-05-01
Bayesian statistics offers a well-founded and powerful fusion methodology also for the fusion of heterogeneous information sources. However, except in special cases, the needed posterior distribution is not analytically derivable. As consequence, Bayesian fusion may cause unacceptably high computational and storage costs in practice. Local Bayesian fusion approaches aim at reducing the complexity of the Bayesian fusion methodology significantly. This is done by concentrating the actual Bayesian fusion on the potentially most task relevant parts of the domain of the Properties of Interest. Our research on these approaches is motivated by an analogy to criminal investigations where criminalists pursue clues also only locally. This publication follows previous publications on a special local Bayesian fusion technique called focussed Bayesian fusion. Here, the actual calculation of the posterior distribution gets completely restricted to a suitably chosen local context. By this, the global posterior distribution is not completely determined. Strategies for using the results of a focussed Bayesian analysis appropriately are needed. In this publication, we primarily contrast different ways of embedding the results of focussed Bayesian fusion explicitly into a global context. To obtain a unique global posterior distribution, we analyze the application of the Maximum Entropy Principle that has been shown to be successfully applicable in metrology and in different other areas. To address the special need for making further decisions subsequently to the actual fusion task, we further analyze criteria for decision making under partial information.
Bayesian parameter estimation for chiral effective field theory
NASA Astrophysics Data System (ADS)
Wesolowski, Sarah; Furnstahl, Richard; Phillips, Daniel; Klco, Natalie
2016-09-01
The low-energy constants (LECs) of a chiral effective field theory (EFT) interaction in the two-body sector are fit to observable data using a Bayesian parameter estimation framework. By using Bayesian prior probability distributions (pdfs), we quantify relevant physical expectations such as LEC naturalness and include them in the parameter estimation procedure. The final result is a posterior pdf for the LECs, which can be used to propagate uncertainty resulting from the fit to data to the final observable predictions. The posterior pdf also allows an empirical test of operator redundancy and other features of the potential. We compare results of our framework with other fitting procedures, interpreting the underlying assumptions in Bayesian probabilistic language. We also compare results from fitting all partial waves of the interaction simultaneously to cross section data compared to fitting to extracted phase shifts, appropriately accounting for correlations in the data. Supported in part by the NSF and DOE.
Shared neural processes support semantic control and action understanding
Davey, James; Rueschemeyer, Shirley-Ann; Costigan, Alison; Murphy, Nik; Krieger-Redwood, Katya; Hallam, Glyn; Jefferies, Elizabeth
2015-01-01
Executive–semantic control and action understanding appear to recruit overlapping brain regions but existing evidence from neuroimaging meta-analyses and neuropsychology lacks spatial precision; we therefore manipulated difficulty and feature type (visual vs. action) in a single fMRI study. Harder judgements recruited an executive–semantic network encompassing medial and inferior frontal regions (including LIFG) and posterior temporal cortex (including pMTG). These regions partially overlapped with brain areas involved in action but not visual judgements. In LIFG, the peak responses to action and difficulty were spatially identical across participants, while these responses were overlapping yet spatially distinct in posterior temporal cortex. We propose that the co-activation of LIFG and pMTG allows the flexible retrieval of semantic information, appropriate to the current context; this might be necessary both for semantic control and understanding actions. Feature selection in difficult trials also recruited ventral occipital–temporal areas, not implicated in action understanding. PMID:25658631
Early Weightbearing After Operatively Treated Ankle Fractures: A Biomechanical Analysis.
Tan, Eric W; Sirisreetreerux, Norachart; Paez, Adrian G; Parks, Brent G; Schon, Lew C; Hasenboehler, Erik A
2016-06-01
No consensus exists regarding the timing of weightbearing after surgical fixation of unstable traumatic ankle fractures. We evaluated fracture displacement and timing of displacement with simulated early weightbearing in a cadaveric model. Twenty-four fresh-frozen lower extremities were assigned to Group 1, bimalleolar ankle fracture (n=6); Group 2, trimalleolar ankle fracture with unfixed small posterior malleolar fracture (n=9); or Group 3, trimalleolar ankle fracture with fixed large posterior malleolar fracture (n=9) and tested with axial compressive load at 3 Hz from 0 to 1000 N for 250 000 cycles to simulate 5 weeks of full weightbearing. Displacement was measured by differential variable reluctance transducer. The average motion at all fracture sites in all groups was significantly less than 1 mm (P < .05). Group 1 displacement of the lateral and medial malleolus fracture was 0.1±0.1 mm and 0.4±0.4 mm, respectively. Group 2 displacement of the lateral, medial, and posterior malleolar fracture was 0.6±0.4 mm, 0.5±0.4 mm, and 0.5±0.6 mm, respectively. Group 3 displacement of the lateral, medial, and posterior malleolar fracture was 0.1±0.1 mm, 0.5±0.7 mm, and 0.5±0.4 mm, respectively. The majority of displacement (64.0% to 92.3%) occurred in the first 50 000 cycles. There was no correlation between fracture displacement and bone mineral density. No significant fracture displacement, no hardware failure, and no new fractures occurred in a cadaveric model of early weightbearing in unstable ankle fracture after open reduction and internal fixation. This study supports further investigation of early weightbearing postoperative protocols after fixation of unstable ankle fractures. © The Author(s) 2016.
Perilimbal sclera mechanical properties: Impact on intraocular pressure in porcine eyes
Man, Xiaofei; Arroyo, Elizabeth; Dunbar, Martha; Reed, David M.; Shah, Neil; Kagemann, Larry; Kim, Wonsuk; Moroi, Sayoko E.
2018-01-01
There is extensive knowledge on the relationship of posterior scleral biomechanics and intraocular pressure (IOP) load on glaucomatous optic neuropathy; however, the role for biomechanical influence of the perilimbal scleral tissue on the aqueous humor drainage pathway, including the distal venous outflow system, and IOP regulation is not fully understood. The purpose of this work is to study the outflow characteristics of perfused porcine eyes relative to the biomechanical properties of the perilimbal sclera, the posterior sclera and the cornea. Enucleated porcine eyes from eleven different animals were perfused with surrogate aqueous at two fixed flow rates while monitoring their IOP. After perfusion, mechanical stress-strain and relaxation tests were conducted on specimens of perilimbal sclera, posterior sclera, and cornea from the same perfused eyes. Statistical analysis of the data demonstrated a strong correlation between increased tangent modulus of the perilimbal sclera tissues and increased perfusion IOP (R2 = 0.74, p = 0.0006 at lower flow rate and R2 = 0.71, p = 0.0011 at higher flow rate). In contrast, there were no significant correlations between IOP and the tangent modulus of the other tissues (Posterior sclera: R2 = 0.17 at lower flow rate and R2 = 0.30 at higher flow rate; cornea: R2 = 0.02 at lower flow rate and R2<0.01 at higher flow rate) nor the viscoelastic properties of any tissue (R2 ≤ 0.08 in all cases). Additionally, the correlation occurred for IOP and not net outflow facility (R2 ≤ 0.12 in all cases). These results provide new evidence that IOP in perfused porcine eyes is strongly influenced by the tangent modulus, sometimes called the tissue stiffness, of the most anterior portion of the sclera, i.e. the limbus. PMID:29718942
[Three dimensional structure of the connective tissue papillae of the tongue in Suncus murinus].
Kobayashi, K; Miyata, K; Iwasaki, S; Takahashi, K
1989-08-01
The surface structure of the connective tissue papillae (CP) of Suncus murinus tongue was observed by SEM after fixing with Karnovsky's fixative and removal of the epithelial cell layer with 3N or 8N HCl. On the surface of the slender conical tongue, there are densely distributed filiform papillae among which fungiform papillae are seen sporadically. A pair of vallate papillae are situated in the posterior region of the tongue. Filiform papillae appear somewhat different externally depending on the dorsal surface of the anterior tongue. At the tip of the tongue, filiform papillae are of a slender conical shape and have a slight depression in the anterior basal portion. The CP of these is seen as a spherical protrusion on which a shallow groove runs in the anteroposterior direction. In the middle region, somewhat large filiform papillae contain CP having one or two small round head-like structures on each spherical protrusion. These head-like structures are increased in number in the posterior region. In the most posterior region of the anterior tongue, there are distributed large filiform papillae having several slender protrusions that surround a basal anterior depression. These large branched filiform papillae have a glove finger like CP. Small conical filiform papillae are distributed in the posterior marginal region of the anterior tongue which have CP of a horse-shoe like protrusion that opens in the anterior direction. Spherical fungiform papillae have CP which are thick columnar in shape with many lateral thin folds running vertically and having a round depression on the top of each. CP of the vallate papillae appear as a beehive like structure.(ABSTRACT TRUNCATED AT 250 WORDS)
Mouthparts in Leptotrombidium larvae (Acariformes: Trombiculidae).
Shatrov, Andrey B; Takahashi, Mamoru; Misumi, Hitoko; Takahashi, Yumi
2016-04-01
Mouthparts of Leptotrombidium larvae (Acariformes: Trombiculidae), potential vectors of tsutsugamushi disease agents, were studied in detail using light microscopy, scanning electron microscopy, and transmission electron microscopy. The mouthparts incorporated within the pseudotagma gnathosoma are composed of the infracapitulum ventrally and the chelicerae dorsally. The ventral wall of the infracapitulum is formed by a wide mentum posteriorly and a narrowed malapophysis anteriorly. The malapophysis firmly envelops the distal cheliceral portions by its lateral walls. The lateral lips of the malapophysis are flexible structures hiding the cheliceral blades in inactive condition and turning back forming a type of temporary sucker closely applied to the host skin during feeding. The roof of the infracapitulum is formed by a weakly sclerotized labrum anteriorly and a cervix with the capitular apodemes extending posteriorly. The labral muscles are lacking. The capitular apodemes serve as origin for pharyngeal dilators running to the dorsal wall of the pharynx fused with the bottom of the infracapitulum. The basal cheliceral segments are separated from each other besides the very posterior portions where they are movably joined by the inner walls. The sigmoid pieces serve for insertion of the cheliceral elevators originating at the posterior portions of the basal segments. The movable digits reveal the solid basal sclerite and the cheliceral blade curved upward with a tricuspid cap on its tip. Dendrites of nerve cells run along the digits to their tips. The ganglia are placed within the basal segments just behind the movable digits. The chelicerae also reveal well developed flexible fixed digits overhanging the basal portions of the blades. The gnathosoma possesses several sets of extrinsic muscles originating at the scutum and at the soft cuticle behind it. Laterally, the gnathosoma bears five-segmented palps with a trifurcate palpal claw. © 2016 Wiley Periodicals, Inc.
Lateral transzygomatic middle fossa approach and its extensions: surgical technique and 3D anatomy.
Chotai, Silky; Kshettry, Varun R; Petrak, Alex; Ammirati, Mario
2015-03-01
Various approaches to lesions involving the middle fossa and cavernous sinus (CS), with and without posterior fossa extension have been described. In the present study, we describe the surgical technique for the extradural lateral tranzygomatic middle fossa approach and its extensions, highlight relevant 3D anatomy. Simulations of the lateral transzygomatic middle fossa approach and its extensions were performed in four silicon-injected formalin fixed cadaveric heads. The step-by-step description and relevant anatomy was documented with 3D photographs. The lateral transzygomatic middle fossa approach is particularly useful for lesions involving the middle fossa with and without CS invasion, extending to the posterior fossa and involving the clinoidal region. This approach incorporates direct lateral positioning of patient, frontotemporal craniotomy with zygomatic arch osteotomy, extradural elevation of the temporal lobe, and delamination of the outer layer of the lateral CS wall. Extradural drilling of the sphenoid wing and anterior clinoid process allows entry into the CS through the superior wall and exposure of the clinoidal segment of the ICA. Posteriorly, drilling the petrous apex allows exposure of the ventral brainstem from trigeminal to facial nerve and can be extended to the interpeduncular fossa by division of the superior petrosal sinus. The present study illustrates 3D anatomical relationships of the lateral transzygomatic middle fossa approach with its extensions. This approach allows wide access to different topographic areas (clinoidal region and clinoidal ICA, the entire CS, and the posterior fossa from the interpeduncular fossa to the facial nerve) via a lateral trajectory. Precise knowledge of technique and anatomy is necessary to properly execute this approach. Copyright © 2014 Elsevier B.V. All rights reserved.
Markolf, Keith L; Jackson, Steven; McAllister, David R
2012-09-01
Syndesmosis (high ankle) sprains produce disruption of the distal tibiofibular ligaments. Forces on the distal fibula that produce these injuries are unknown. Twenty-seven fresh-frozen lower extremities were used for this study. A load cell recorded forces acting on the distal fibula from forced ankle dorsiflexion and applied external foot torque; medial-lateral and anterior-posterior displacements of the distal fibula were recorded. Fibular forces and axial displacements were also recorded with applied axial force. During forced ankle dorsiflexion and external foot torque tests, the distal fibula always displaced posteriorly with respect to the tibia with no measurable medial-lateral displacement. With 10 Nm dorsiflexion moment, cutting the tibiofibular ligaments approximately doubled fibular force and displacement values. Cutting the tibiofibular ligaments significantly increased fibular displacement from applied external foot torque. Fibular forces and axial displacements from applied axial weight-bearing force were highest with the foot dorsiflexed. The highest mean fibular force in the study (271.9 N) occurred with 10 Nm external foot torque applied to a dorsiflexed foot under 1000 N axial force. Two important modes of loading that could produce high ankle sprains were identified: forced ankle dorsiflexion and external foot torque applied to a dorsiflexed ankle loaded with axial force. The distal tibiofibular ligaments restrained fibular displacement during these tests. Residual mortise widening observed at surgery may be the result of tibiofibular ligament injuries caused by posterior displacement of the fibula. Therefore, a syndesmosis screw used to fix the fibula would be subjected to posterior bending forces from these loading modes. Ankle bracing to prevent extreme ankle dorsiflexion during rehabilitation may be advisable to prevent excessive fibular motions that could affect syndesmosis healing.
Atalar, Ata C; Tunalı, Onur; Erşen, Ali; Kapıcıoğlu, Mehmet; Sağlam, Yavuz; Demirhan, Mehmet S
2017-01-01
In intraarticular distal humerus fractures, internal fixation with double plates is the gold standard treatment. However the optimal plate configuration is not clear in the literature. The aim of this study was to compare the biomechanical stability of the parallel and the orthogonal anatomical locking plating systems in intraarticular distal humerus fractures in artificial humerus models. Intraarticular distal humerus fracture (AO13-C2) with 5 mm metaphyseal defect was created in sixteen artificial humeral models. Models were fixed with either orthogonal or parallel plating systems with locking screws (Acumed elbow plating systems). Both systems were tested for their stiffness with loads in axial compression, varus, valgus, anterior and posterior bending. Then plastic deformation after cyclic loading in posterior bending and load to failure in posterior bending were tested. The failure mechanisms of all the samples were observed. Stiffness values in every direction were not significantly different among the orthogonal and the parallel plating groups. There was no statistical difference between the two groups in plastic deformation values (0.31 mm-0.29 mm) and load to failure tests in posterior bending (372.4 N-379.7 N). In the orthogonal plating system most of the failures occurred due to the proximal shaft fracture, whereas in the parallel plating system failure occurred due to the shift of the most distal screw in proximal fragment. Our study showed that both plating systems had similar biomechanical stabilities when anatomic plates with distal locking screws were used in intraarticular distal humerus fractures in artificial humerus models. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.
Gnat, Rafael; Spoor, Kees; Pool-Goudzwaard, Annelies
2015-10-01
The role of so-called local muscle system in motor control of the lower back and pelvis is a subject of ongoing debate. Prevailing beliefs in stabilizing function of this system were recently challenged. This study investigated the impact of in vitro simulated force of transversely oriented fibres of the transversus abdominis muscle (a part of the local system) on flexibility of the sacroiliac joint during asymmetric moment application to the pelvis. In 8 embalmed specimens an incremental moment was applied in the sagittal plane to one innominate with respect to the fixed contralateral innominate. Ranges of motion of the sacroiliac joint were recorded using the Vicon Motion Capture System. Load-deformation curves were plotted and flexibility of the sacroiliac joint was calculated separately for anterior and posterior rotations of the innominate, with and without simulated muscle force. Flexibility of the sacroiliac joint was significantly bigger during anterior rotation of the innominate, as compared to posterior rotation (Anova P<0.05). After application of simulated force of transversus abdominis, flexibility of the joint did not change both during anterior and posterior rotations of the innominate. A lack of a stiffening effect of simulated transversus abdominis force on the sacroiliac joint was demonstrated. Earlier hypotheses suggesting a stiffening influence of this muscle on the pelvis cannot be confirmed. Consistent with previous findings smaller flexibility of the joint recorded during posterior rotation of the innominate may be of clinical importance for physio- and manual therapists. However, major limitations of the study should be acknowledged: in vitro conditions and simulation of only solitary muscle force. Copyright © 2015 Elsevier Ltd. All rights reserved.
Defining success in clinical trials--profiling pregabalin, the newest AED.
Ryvlin, P
2005-11-01
The efficacy and safety of pregabalin as adjunctive therapy for patients with partial epilepsy with or without secondary generalization has been established by four randomized, 12-week, double-blind, placebo-controlled trials (n = 1396) and four long-term open-label studies (n = 1480). Patients in the three fixed-dose trials were >/=12 years of age, had >/=6 partial seizures and no 4-week seizure-free period during the 8-week baseline period. Seventy-three per cent of patients were taking >/=2 concomitant antiepileptic drugs. Responder rates across the effective doses (150-600 mg/day) ranged from 14% to 51% and demonstrated a significant dose-response relationship. The most common adverse events were central nervous system related, generally mild or moderate, transient, and tended to be dose related. The fourth placebo-controlled trial compared a fixed dose of pregabalin 600 mg/day with a flexible-dose regimen (150-600 mg/day). Responder rates were greater for both the fixed dose (45.3%, P < 0.001) and flexible dose (31.3%, P < 0.001) when compared with placebo (11.0%). Compared with the fixed-dose group, the flexible-dose patients had a lower incidence of adverse events and study discontinuations. In long-term open-label trials, the efficacy of pregabalin was maintained with respect to 50% responder rates suggesting no obvious tolerance developing over 2 years. Seizure-free rates were 8.9% and 5.8% for the last 6 months and 1 year of pregabalin treatment, respectively. Long-term open-label pregabalin treatment was well tolerated.
Khetarpal, Shaleen; Chouksey, Ajay; Bele, Anand; Vishnoi, Rahul
2018-01-01
Favorable esthetics is one of the most important treatment outcomes in dentistry, and to achieve this, interdisciplinary approaches are often required. Ridge deficiencies can be corrected for both, soft- and hard-tissue discrepancies. To overcome such defects, not only a variety of prosthetic options are at our disposal but also several periodontal plastic surgical techniques are available as well. Various techniques have been described and revised, over the year to correct ridge defects. For enhancing soft-tissue contours in the anterior region, the subepithelial connective tissue graft is the treatment of choice. A combination of alloplastic bone graft in adjunct to connective tissue graft optimizes ridge augmentation and minimizes defects. The present case report describes the use of vascular interpositional connective tissue graft in combination with alloplastic bone graft for correction of Seibert's Class III ridge deficiency followed by a fixed partial prosthesis to achieve a better esthetic outcome.
Khetarpal, Shaleen; Chouksey, Ajay; Bele, Anand; Vishnoi, Rahul
2018-01-01
Favorable esthetics is one of the most important treatment outcomes in dentistry, and to achieve this, interdisciplinary approaches are often required. Ridge deficiencies can be corrected for both, soft- and hard-tissue discrepancies. To overcome such defects, not only a variety of prosthetic options are at our disposal but also several periodontal plastic surgical techniques are available as well. Various techniques have been described and revised, over the year to correct ridge defects. For enhancing soft-tissue contours in the anterior region, the subepithelial connective tissue graft is the treatment of choice. A combination of alloplastic bone graft in adjunct to connective tissue graft optimizes ridge augmentation and minimizes defects. The present case report describes the use of vascular interpositional connective tissue graft in combination with alloplastic bone graft for correction of Seibert's Class III ridge deficiency followed by a fixed partial prosthesis to achieve a better esthetic outcome. PMID:29568176
Post-combustion CO2 capture with activated carbons using fixed bed adsorption
NASA Astrophysics Data System (ADS)
Al Mesfer, Mohammed K.; Danish, Mohd; Fahmy, Yasser M.; Rashid, Md. Mamoon
2018-03-01
In the current work, the capturing of carbon dioxide from flue gases of post combustion emission using fixed bed adsorption has been carried out. Two grades of commercial activated carbon (sorbent-1 and sorbent-2) were used as adsorbent. Feed consisting of CO2 and N2 mixture was used for carrying out the adsorption. The influence of bed temperature, feed rate, equilibrium partial pressure and initial % CO2 in feed were considered for analyzing adsorption-desorption process. It was found that the total adsorption-desorption cycle time decreases with increased column temperature and feed rates. The time required to achieve the condition of bed saturation decreases with increased bed temperature and feed rates. The amount of CO2 adsorbed/Kg of the adsorbent declines with increased bed temperature with in studied range for sorbent-1 and sorbent-2. It was suggested that the adsorption capacity of the both the sorbents increases with increased partial pressure of the gas.
Lili, Yang; Debiao, Du; Ruoyu, Ning; Deying, Chen; Junling, Wu
2017-08-01
Objective In this study, we aimed to evaluate the clinical effect of single-retainer all-ceramic resin-bonded fixed partial denture (RBFPD) on the single anterior tooth loss patients. Methods A total of 20 single-retainer all-ceramic RBFPD were fabricated and evaluated in a two-year follow-up observation. The restorations were examined on the basis of the American Public Health Association (APHA) criteria. Results A total of 20 single-retainer all-ceramic RBFPD achieved class A evaluation after a six-month follow-up observation. One single-retainer all-ceramic RBFPD was classified as class B for secondary caries after a one-year follow-up observation. After a two-year follow-up observation, one single-retainer all-ceramic RBFPD was classified as class B because of secondary caries, and one single-retainer all-ceramic RBFPD was classified as class B because of fracture. Conclusion Single-retainer all-ceramic RBFPD is a promising and optional method in replacing single anterior tooth.
[Computer aided design for fixed partial denture framework based on reverse engineering technology].
Sun, Yu-chun; Lü, Pei-jun; Wang, Yong
2006-03-01
To explore a computer aided design (CAD) route for the framework of domestic fixed partial denture (FPD) and confirm the suitable method of 3-D CAD. The working area of a dentition model was scanned with a 3-D mechanical scanner. Using the reverse engineering (RE) software, margin and border curves were extracted and several reference curves were created to ensure the dimension and location of pontic framework that was taken from the standard database. The shoulder parts of the retainers were created after axial surfaces constructed. The connecting areas, axial line and curving surface of the framework connector were finally created. The framework of a three-unit FPD was designed with RE technology, which showed smooth surfaces and continuous contours. The design route is practical. The result of this study is significant in theory and practice, which will provide a reference for establishing the computer aided design/computer aided manufacture (CAD/CAM) system of domestic FPD.
Yang, Yandong; Zhang, Liang; Cheng, Jun; Zhang, Shujun; Li, Baikun; Peng, Yongzhen
2017-09-01
This study tested the feasibility of plug-flow integrated fixed-film activated sludge (IFAS) reactor in applying sewage partial nitritation/anammox (PN/A) process. The IFAS reactor was fed with real pre-treated sewage (C/N ratio=1.3) and operated for 200days. High nitrogen removal efficiency of 82% was achieved with nitrogen removal rates of 0.097±0.019kgN/(m 3 ·d). Therefore, plug-flow IFAS reactor could be an alternative to applying sewage PN/A process. Besides, it was found that the stability of sewage PN/A process was significantly affected by residual ammonium. Nitrate accumulated in effluent and PN/A performance deteriorated when residual ammonium was below 1mg/L. On the contrary, long-term stable PN/A operation was achieved when residual ammonium was over 3mg/L. Copyright © 2017 Elsevier Ltd. All rights reserved.
Tanaka, Junko; Tanaka, Masahiro
2010-01-01
The purpose of this study was to investigate the relationship between the number of missing teeth (MT) and the statuses of oral environmental factors (the stimulated salivary flow rate, buffering capacity, and the counts of mutans streptococci, lactobacilli, and Candida) in the elderly. The subjects were 64 elderly subjects with fixed prostheses and 49 who wore removable partial dentures aged over 65 years. We used one-way ANOVA to test for overall differences of the number of MT among 5 oral environmental factors. The significant differences were observed in the lactobacilli counts for different number of MT. The number of MT increased with an increase in the lactobacilli counts with removable denture. In conclusion, for the patients wearing removable dentures, increasing number of MT was associated with an increase in the lactobacilli counts in saliva. For the patients with crowns and fixed partial dentures, the number of MT was not significantly affected by salivary mutans streptococci, lactobacilli, and Candida counts.
Consequences of tooth loss: 2. Dentist considerations--restorative problems and implications.
Craddock, Helen L
2010-01-01
Partial tooth loss is much less well tolerated by patients than was previously the case and, on occasions, when extraction is inevitable, they may seek prosthetic replacement. This paper explores some of the consequences of tooth loss that may cause difficulties in tooth replacement, particularly if replacement is delayed for some time. An awareness of potential difficulties, particularly with posterior tooth replacement, will allow clinicians to make treatment decisions in the light of current evidence.
Unified Description of Scattering and Propagation FY15 Annual Report
2015-09-30
the Texas coast. For both cases a conditional posterior probability distribution ( PPD ) is formed for a parameter space that includes both geoacoustic...for this second application of ME. For each application of ME it is important to note that a new likelihood function and thus PPD is computed. One...the 50-700 Hz band. These data offered a means by which the results of using the ship radiated noise could be partially validated. The conditional PPD
Shoi, K; Fueki, K; Usui, N; Taira, M; Wakabayashi, N
2014-07-01
It is well known that shortened dental arch decreases masticatory function. However, its potential to change brain activity during mastication is unknown. The present study investigates the effect of a shortened posterior dental arch with mandibular removable partial dentures (RPDs) on brain activity during gum chewing. Eleven subjects with missing mandibular molars (mean age, 66.1 years) on both sides received experimental RPDs with interchangeable artificial molars in a crossover trial design. Brain activity during gum chewing with RPDs containing (full dental arch) and lacking artificial molars (shortened dental arch) was measured using functional magnetic resonance imaging. Additionally, masticatory function was evaluated for each dental arch type. Food comminuting and mixing ability and the perceived chewing ability were significantly lower in subjects with a shortened dental arch than those with a full dental arch (P < 0.05). Brain activation during gum chewing with the full dental arch occurred in the middle frontal gyrus, primary sensorimotor cortex extending to the pre-central gyrus, supplementary motor area, putamen, insula and cerebellum. However, middle frontal gyrus activation was not observed during gum chewing with the shortened dental arch. These results suggest that shortened dental arch affects human brain activity in the middle frontal gyrus during gum chewing, and the decreased middle frontal gyrus activation may be associated with decreased masticatory function. © 2014 John Wiley & Sons Ltd.
MC3: Multi-core Markov-chain Monte Carlo code
NASA Astrophysics Data System (ADS)
Cubillos, Patricio; Harrington, Joseph; Lust, Nate; Foster, AJ; Stemm, Madison; Loredo, Tom; Stevenson, Kevin; Campo, Chris; Hardin, Matt; Hardy, Ryan
2016-10-01
MC3 (Multi-core Markov-chain Monte Carlo) is a Bayesian statistics tool that can be executed from the shell prompt or interactively through the Python interpreter with single- or multiple-CPU parallel computing. It offers Markov-chain Monte Carlo (MCMC) posterior-distribution sampling for several algorithms, Levenberg-Marquardt least-squares optimization, and uniform non-informative, Jeffreys non-informative, or Gaussian-informative priors. MC3 can share the same value among multiple parameters and fix the value of parameters to constant values, and offers Gelman-Rubin convergence testing and correlated-noise estimation with time-averaging or wavelet-based likelihood estimation methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McNamara, A; Underwood, T; Wo, J
2016-06-15
Purpose: Anal cancer patients treated using a posterior proton beam may be at risk of vaginal wall injury due to the increased linear energy transfer (LET) and relative biological effectiveness (RBE) at the beam distal edge. We investigate the vaginal dose received. Methods: Five patients treated for anal cancer with proton pencil beam scanning were considered, all treated to a prescription dose of 54 Gy(RBE) over 28–30 fractions. Dose and LET distributions were calculated using the Monte Carlo simulation toolkit TOPAS. In addition to the standard assumption of a fixed RBE of 1.1, variable RBE was considered via the applicationmore » of published models. Dose volume histograms (DVHs) were extracted for the planning treatment volume (PTV) and vagina, the latter being used to calculate the vaginal normal tissue complication probability (NTCP). Results: Compared to the assumption of a fixed RBE of 1.1, the variable RBE model predicts a dose increase of approximately 3.3 ± 1.7 Gy at the end of beam range. NTCP parameters for the vagina are incomplete in the current literature, however, inferring value ranges from the existing data we use D{sub 50} = 50 Gy and LKB model parameters a=1–2 and m=0.2–0.4. We estimate the NTCP for the vagina to be 37–48% and 42–47% for the fixed and variable RBE cases, respectively. Additionally, a difference in the dose distribution was observed between the analytical calculation and Monte Carlo methods. We find that the target dose is overestimated on average by approximately 1–2%. Conclusion: For patients treated with posterior beams, the vaginal wall may coincide with the distal end of the proton beam and may receive a substantial increase in dose if variable RBE models are applied compared to using the current clinical standard of RBE equal to 1.1. This could potentially lead to underestimating toxicities when treating with protons.« less
Objective Assessment of Fall Risk in Parkinson's Disease Using a Body-Fixed Sensor Worn for 3 Days
Weiss, Aner; Herman, Talia; Giladi, Nir; Hausdorff, Jeffrey M.
2014-01-01
Background Patients with Parkinson's disease (PD) suffer from a high fall risk. Previous approaches for evaluating fall risk are based on self-report or testing at a given time point and may, therefore, be insufficient to optimally capture fall risk. We tested, for the first time, whether metrics derived from 3 day continuous recordings are associated with fall risk in PD. Methods and Materials 107 patients (Hoehn & Yahr Stage: 2.6±0.7) wore a small, body-fixed sensor (3D accelerometer) on lower back for 3 days. Walking quantity (e.g., steps per 3-days) and quality (e.g., frequency-derived measures of gait variability) were determined. Subjects were classified as fallers or non-fallers based on fall history. Subjects were also followed for one year to evaluate predictors of the transition from non-faller to faller. Results The 3 day acceleration derived measures were significantly different in fallers and non-fallers and were significantly correlated with previously validated measures of fall risk. Walking quantity was similar in the two groups. In contrast, the fallers walked with higher step-to-step variability, e.g., anterior-posterior width of the dominant frequency was larger (p = 0.012) in the fallers (0.78±0.17 Hz) compared to the non-fallers (0.71±0.07 Hz). Among subjects who reported no falls in the year prior to testing, sensor-derived measures predicted the time to first fall (p = 0.0034), whereas many traditional measures did not. Cox regression analysis showed that anterior-posterior width was significantly (p = 0.0039) associated with time to fall during the follow-up period, even after adjusting for traditional measures. Conclusions/Significance These findings indicate that a body-fixed sensor worn continuously can evaluate fall risk in PD. This sensor-based approach was able to identify transition from non-faller to faller, whereas many traditional metrics were not successful. This approach may facilitate earlier detection of fall risk and may in the future, help reduce high costs associated with falls. PMID:24801889
A Bayesian Hybrid Adaptive Randomisation Design for Clinical Trials with Survival Outcomes.
Moatti, M; Chevret, S; Zohar, S; Rosenberger, W F
2016-01-01
Response-adaptive randomisation designs have been proposed to improve the efficiency of phase III randomised clinical trials and improve the outcomes of the clinical trial population. In the setting of failure time outcomes, Zhang and Rosenberger (2007) developed a response-adaptive randomisation approach that targets an optimal allocation, based on a fixed sample size. The aim of this research is to propose a response-adaptive randomisation procedure for survival trials with an interim monitoring plan, based on the following optimal criterion: for fixed variance of the estimated log hazard ratio, what allocation minimizes the expected hazard of failure? We demonstrate the utility of the design by redesigning a clinical trial on multiple myeloma. To handle continuous monitoring of data, we propose a Bayesian response-adaptive randomisation procedure, where the log hazard ratio is the effect measure of interest. Combining the prior with the normal likelihood, the mean posterior estimate of the log hazard ratio allows derivation of the optimal target allocation. We perform a simulation study to assess and compare the performance of this proposed Bayesian hybrid adaptive design to those of fixed, sequential or adaptive - either frequentist or fully Bayesian - designs. Non informative normal priors of the log hazard ratio were used, as well as mixture of enthusiastic and skeptical priors. Stopping rules based on the posterior distribution of the log hazard ratio were computed. The method is then illustrated by redesigning a phase III randomised clinical trial of chemotherapy in patients with multiple myeloma, with mixture of normal priors elicited from experts. As expected, there was a reduction in the proportion of observed deaths in the adaptive vs. non-adaptive designs; this reduction was maximized using a Bayes mixture prior, with no clear-cut improvement by using a fully Bayesian procedure. The use of stopping rules allows a slight decrease in the observed proportion of deaths under the alternate hypothesis compared with the adaptive designs with no stopping rules. Such Bayesian hybrid adaptive survival trials may be promising alternatives to traditional designs, reducing the duration of survival trials, as well as optimizing the ethical concerns for patients enrolled in the trial.
[Usefullness of intrasacral fixation in an extremely unstable lumbosacral spine].
Nishiura, Tsukasa; Nishiguchi, Mitsuhisa; Kusaka, Noboru; Takayama, Kazuhiro; Maeda, Yasuhiko; Ogihara, Kotaro; Nakagawa, Minoru
2007-04-01
Intrasacral fixation technique devised by Jackson is said to provide rigid lumbosacral fixation. We treated 3 cases of lumbosacral lesions using this technique in which lumbosacral segment had become extremely unstable during surgical intervention adding to the effect of original lesions. In all cases, surgeries were performed in 2 stages, intrasacral fixation and anterior stabilization. Case 1: A 52-year-old male was diagnosed fungal discitis and spondylitis at L4 and L5. X-ray showed destruction of the vertebral bodies. L2, L3 and sacrum were fixed posteriorly using the intrasacral fixation technique. One week after the first operation, L4 and L5 vertebral bodies were replaced by long fibula grafts through the extraperitoneal approach. Case 2: A 25-year-old female with cauda equina syndrome and abnormal body form diagnosed as having spondyloptosis in which the entire vertebral body of L5 had descended below the endplate of S1. MR imaging revealed marked canal stenosis at the S1 level. In the first surgery, L5 vertebral body was resected through the transperitoneal approach. After 1 week of bed rest, posterior segments of L5 were resected, L4 was affixed to the sacrum and anterior stabilization was achieved with 2 mesh cages and lumbosacral spine was fixed using the intrasacral fixation technique. Case 3: A 64-year-old female was diagnosed as having pyogenic discitis and osteomyelitis at the L5-S1 level. In spite of successful medical treatment for infection, low back pain continued. Radiologically, L5 vertebral body was shown to have collapsed and slipped anteriorly over the sacrum. L3, L4 and sacrum were fixed by intrasacral fixation. One week after the first operation, the L5/S1 disc and the suppurtive vertebral bodies were resected through the extraperitoneal approach and anterior stabilization was performed with iliac bone grafts. At follow-up for a minimum of 6 months, initial fixation was maintained in all 3 cases and bony fusion was obtained. The intrasacral fixation technique was considered to be effective for extremely unstable lumbosacral lesions.
Cryopreservation of roe deer abomasal nematodes for morphological identification.
Beraldo, Paola; Pascotto, Ernesto
2014-02-01
Conventional methods to preserve adult nematodes for taxonomic purposes involve the use of fixative or clearing solutions (alcohol, formaldehyde, AFA and lactophenol), which cause morphological alterations and are toxic. The aim of this study is to propose an alternative method based on glycerol-cryopreservation of nematodes for their subsequent identification. Adults of trichostrongylid nematodes from the abomasum of roe deer (Capreolus capreolus Linnaeus) were glycerol-cryopreserved and compared with those fixed in formaldehyde, fresh and frozen without cryoprotectans. Morphology, transparency and elasticity of the anterior and posterior portion of male nematodes were compared, especially the caudal cuticular bursa and genital accessories. The method presented is quick and easy to use, and the quality of nematode specimens is better than that of nematodes fixed by previously used fixatives. Moreover, glycerol cryopreserved nematodes can be stored for a long time at -20 degrees C in perfect condition and they could be suitable for further analyses, such as histological or ultrastructural examinations.
Suero, Eduardo M; Citak, Musa; Cross, Michael B; Bosscher, Marianne R F; Ranawat, Anil S; Pearle, Andrew D
2012-08-01
Patients with anterior cruciate ligament (ACL) deficiency may have increased failure rates with UKA as a result of abnormal contact stresses and altered knee kinematics. Variations in the slope of the tibial component in UKA may alter tibiofemoral translation, and affect outcomes. This cadaveric study evaluated tibiofemoral translation during the Lachman and pivot shift tests after changing the slope of a fixed bearing unicondylar tibial component. Sectioning the ACL increased tibiofemoral translation in both the Lachman and pivot shift tests (P<0.05). Tibial slope leveling (decreasing the posterior slope) of the polyethylene insert in a UKA decreases anteroposterior tibiofemoral translation in the sagittal plane to a magnitude similar to that of the intact knee. With 8° of tibial slope leveling, anterior tibial translation during the Lachman test decreased by approximately 5mm. However, no variation in slope altered the pivot shift kinematics in the ACL deficient knees. Copyright © 2011 Elsevier B.V. All rights reserved.
Geckili, Onur; Bilhan, Hakan; Ceylan, Gulsum; Cilingir, Altug
2013-02-01
The prosthetic treatment of patients with an edentulous maxilla opposing mandibular natural teeth is one of the most challenging endeavors that face clinicians. Occlusal forces from the opposing natural teeth may cause fractures in the maxillary prosthesis and also result in advanced bone loss of the edentulous maxilla. With the presence of extreme gagging reflex, the treatment may become more complicated. This article describes and illustrates the 2-stage surgical and prosthetic treatment of a patient with an edentulous maxilla opposing natural teeth. In the beginning, the patient was treated with 4 implants and a maxillary implant-supported overdenture. The extreme gagging reflex and the occlusal forces from the mandibular natural teeth obligated the team a second stage surgical and prosthetic treatment, which included increasing the number of implants after bilateral sinus lifting in the posterior maxilla and fabricating a maxillary fixed hybrid prosthesis made of micro-ceramic composite that yielded a satisfactory result.
NASA Technical Reports Server (NTRS)
Usher, P. D.
1971-01-01
The almucantar radio telescope development and characteristics are presented. The radio telescope consists of a paraboloidal reflector free to rotate in azimuth but limited in altitude between two fixed angles from the zenith. The fixed angles are designed to provide the capability where sources lying between two small circles parallel with the horizon (almucantars) are accessible at any one instant. Basic geometrical considerations in the almucantar design are presented. The capabilities of the almucantar telescope for source counting and for monitoring which are essential to a resolution of the cosmological problem are described.
NASA Astrophysics Data System (ADS)
Péli, Zoltán; Nagy, Sándor; Sailer, Kornel
2018-02-01
The effect of the O(partial4) terms of the gradient expansion on the anomalous dimension η and the correlation length's critical exponent ν of the Wilson-Fisher fixed point has been determined for the Euclidean 3-dimensional O( N) models with N≥ 2 . Wetterich's effective average action renormalization group method is used with field-independent derivative couplings and Litim's optimized regulator. It is shown that the critical theory is well approximated by the effective average action preserving O( N) symmetry with an accuracy of O(η).
Student Performance in Measuring Distance with Wavelengths in Various Settings
NASA Astrophysics Data System (ADS)
White, Gary
2015-04-01
When physics students are asked to measure the distance between two fixed locations using a pre-defined wavelength as a ruler, there is a surprising failure rate, at least partially due to the fact that the ``ruler'' to be used is not fixed in length (see ``Is a Simple Measurement Task a Roadblock to Student Understanding of Wave Phenomena?,'' by and references therein). I will show some data from introductory classes (algebra- and calculus-based) that replicate this result, and also show some interesting features when comparing a setting involving slinkies with a setting involving surface waves on water.
Bowyer, A E; Hillarp, A; Ezban, M; Persson, P; Kitchen, S
2016-07-01
Essentials Validated assays are required to precisely measure factor IX (FIX) activity in FIX products. N9-GP and two other FIX products were assessed in various coagulation assay systems at two sites. Large variations in FIX activity measurements were observed for N9-GP using some assays. One-stage and chromogenic assays accurately measuring FIX activity for N9-GP were identified. Background Measurement of factor IX activity (FIX:C) with activated partial thromboplastin time-based one-stage clotting assays is associated with a large degree of interlaboratory variation in samples containing glycoPEGylated recombinant FIX (rFIX), i.e. nonacog beta pegol (N9-GP). Validation and qualification of specific assays and conditions are necessary for the accurate assessment of FIX:C in samples containing N9-GP. Objectives To assess the accuracy of various one-stage clotting and chromogenic assays for measuring FIX:C in samples containing N9-GP as compared with samples containing rFIX or plasma-derived FIX (pdFIX) across two laboratory sites. Methods FIX:C, in severe hemophilia B plasma spiked with a range of concentrations (from very low, i.e. 0.03 IU mL(-1) , to high, i.e. 0.90 IU mL(-1) ) of N9-GP, rFIX (BeneFIX), and pdFIX (Mononine), was determined at two laboratory sites with 10 commercially available one-stage clotting assays and two chromogenic FIX:C assays. Assays were performed with a plasma calibrator and different analyzers. Results A high degree of variation in FIX:C measurement was observed for one-stage clotting assays for N9-GP as compared with rFIX or pdFIX. Acceptable N9-GP recovery was observed in the low-concentration to high-concentration samples tested with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays. Similar patterns of FIX:C measurement were observed at both laboratory sites, with minor differences probably being attributable to the use of different analyzers. Conclusions These results suggest that, of the reagents tested, FIX:C in N9-GP-containing plasma samples can be most accurately measured with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays. © 2016 International Society on Thrombosis and Haemostasis.
Aguero-Valverde, Jonathan
2013-01-01
In recent years, complex statistical modeling approaches have being proposed to handle the unobserved heterogeneity and the excess of zeros frequently found in crash data, including random effects and zero inflated models. This research compares random effects, zero inflated, and zero inflated random effects models using a full Bayes hierarchical approach. The models are compared not just in terms of goodness-of-fit measures but also in terms of precision of posterior crash frequency estimates since the precision of these estimates is vital for ranking of sites for engineering improvement. Fixed-over-time random effects models are also compared to independent-over-time random effects models. For the crash dataset being analyzed, it was found that once the random effects are included in the zero inflated models, the probability of being in the zero state is drastically reduced, and the zero inflated models degenerate to their non zero inflated counterparts. Also by fixing the random effects over time the fit of the models and the precision of the crash frequency estimates are significantly increased. It was found that the rankings of the fixed-over-time random effects models are very consistent among them. In addition, the results show that by fixing the random effects over time, the standard errors of the crash frequency estimates are significantly reduced for the majority of the segments on the top of the ranking. Copyright © 2012 Elsevier Ltd. All rights reserved.
Al Refai, Roa'a; Saker, Samah
2018-01-01
The expected length of service and reasons for fixed dental prostheses (FDPs) replacement are a frequent inquiry by patients while the answers were mainly based on studies reports that was conducted outside the middle east region. This clinical and radiographic survey was constructed to assess and survey clinically and radiographically the reasons of replacement of metal-ceramic fixed dental prostheses, amongst patients reporting at dental school in Taibah University. Between January and May 2016, 151 patients were recruited for this study. Interview (include questions pertained to the length of service of the prosthesis, the nature of complaint as told by patient in her own words), clinical examination, intra-oral photographs, and periapical radiographs, were done by the researchers. The parameters assessed were secondary caries, open margins, loss of retention, failure of endodontic treatment of the abutment and periodontal diseases. A total number of 249 failed fixed dental prostheses were evaluated. Of which 180 (39.7%) were single crowns, 159 (35.0%) were retainers and 117 (25.8%) were pontics in 69 fixed partial denture. The most common reason for replacement of fixed restorations was periodontal diseases affecting 92.8% of all types' restorations, followed by defective margin in 90.4% of examined restoration, poor aesthetic in 88% of restorations, while periapical involvement was found in 85.5% of fixed dental prosthesis. The survival rates of fixed prostheses were not predictable, and no association was found between number of years in service and the number of restorations. The most common reasons for replacing single unit fixed dental prostheses are periodontal diseases and periapical involvement, while defective margins and poor aesthetic mainly associated with multi-unit fixed dental prostheses. Key words: Failure, Fixed dental prosthesis, Survival, Replacement.
Weather Impact on Airport Arrival Meter Fix Throughput
NASA Technical Reports Server (NTRS)
Wang, Yao
2017-01-01
Time-based flow management provides arrival aircraft schedules based on arrival airport conditions, airport capacity, required spacing, and weather conditions. In order to meet a scheduled time at which arrival aircraft can cross an airport arrival meter fix prior to entering the airport terminal airspace, air traffic controllers make regulations on air traffic. Severe weather may create an airport arrival bottleneck if one or more of airport arrival meter fixes are partially or completely blocked by the weather and the arrival demand has not been reduced accordingly. Under these conditions, aircraft are frequently being put in holding patterns until they can be rerouted. A model that predicts the weather impacted meter fix throughput may help air traffic controllers direct arrival flows into the airport more efficiently, minimizing arrival meter fix congestion. This paper presents an analysis of air traffic flows across arrival meter fixes at the Newark Liberty International Airport (EWR). Several scenarios of weather impacted EWR arrival fix flows are described. Furthermore, multiple linear regression and regression tree ensemble learning approaches for translating multiple sector Weather Impacted Traffic Indexes (WITI) to EWR arrival meter fix throughputs are examined. These weather translation models are developed and validated using the EWR arrival flight and weather data for the period of April-September in 2014. This study also compares the performance of the regression tree ensemble with traditional multiple linear regression models for estimating the weather impacted throughputs at each of the EWR arrival meter fixes. For all meter fixes investigated, the results from the regression tree ensemble weather translation models show a stronger correlation between model outputs and observed meter fix throughputs than that produced from multiple linear regression method.
Villena Carpio, Oswaldo; Royle, J. Andrew; Weir, Linda; Foreman, Tasha M.; Gazenski, Kimberly D.; Campbell Grant, Evan H.
2016-01-01
We present the first regional trends in anuran occupancy for eight states of the southeastern United States, based on 13 y (2001–2013) of North American Amphibian Monitoring Program (NAAMP) data. The NAAMP is a longterm monitoring program in which observers collect anuran calling observation data at fixed locations along random roadside routes. We assessed occupancy trends for 14 species. We found weak evidence for a general regional pattern of decline in calling anurans within breeding habitats along roads in the southeastern USA over the last 13 y. Two species had positive regional trends with 95% posterior intervals that did not include zero (Hyla cinerea and Pseudacris crucifer). Five other species also showed an increasing trend, while eight species showed a declining trend, although 95% posterior intervals included zero. We also assessed state level trends for 107 species/state combinations. Of these, 14 showed a significant decline and 12 showed a significant increase in occupancy (i.e., credible intervals did not include zero for these 26 trends).
Arthroscopic-assisted latissimus dorsi transfer for subscapularis deficiency.
Kany, Jean; Guinand, Régis; Croutzet, Pierre; Valenti, Philippe; Werthel, Jean David; Grimberg, Jean
2016-04-01
Few salvage procedures have been described in case of irreparable subscapularis tear and with variable outcomes. Latissimus dorsi transfer has been widely proposed as a transfer for irreparable posterio-superior rotator cuff tear with good outcomes. The anatomic feasibility of the latissimus dorsi to reconstruct the antero-superior irreparable rotator cuff tear has been suggested, but no clinical study has ever been published. We hypothesized that it was possible to use an arthroscopic-assisted latissimus dorsi transfer to reconstruct the subscapularis function. Five patients were enrolled. A 5-7-cm axillary incision was performed to release the latissimus dorsi tendon from its humeral insertion, the teres major muscle and the apex of the scapula. Afterwards, under arthroscopic control, a 7-mm-diameter tunnel was drilled at the anterior and superior part of the humeral head with an oblique inferior and posterior direction. The tubularized latissimus dorsi tendon was introduced into the tunnel and fixed with a ZipLoop on the posterior humeral cortex. The authors show overall good experience with this technique. Level IV-a, case series.
An overview of zirconia ceramics: basic properties and clinical applications.
Manicone, Paolo Francesco; Rossi Iommetti, Pierfrancesco; Raffaelli, Luca
2007-11-01
Zirconia (ZrO2) is a ceramic material with adequate mechanical properties for manufacturing of medical devices. Zirconia stabilized with Y2O3 has the best properties for these applications. When a stress occurs on a ZrO2 surface, a crystalline modification opposes the propagation of cracks. Compression resistance of ZrO2 is about 2000 MPa. Orthopedic research led to this material being proposed for the manufacture of hip head prostheses. Prior to this, zirconia biocompatibility had been studied in vivo; no adverse responses were reported following the insertion of ZrO2 samples into bone or muscle. In vitro experimentation showed absence of mutations and good viability of cells cultured on this material. Zirconia cores for fixed partial dentures (FPD) on anterior and posterior teeth and on implants are now available. Clinical evaluation of abutments and periodontal tissue must be performed prior to their use. Zirconia opacity is very useful in adverse clinical situations, for example, for masking of dischromic abutment teeth. Radiopacity can aid evaluation during radiographic controls. Zirconia frameworks are realized by using computer-aided design/manufacturing (CAD/CAM) technology. Cementation of Zr-ceramic restorations can be performed with adhesive luting. Mechanical properties of zirconium oxide FPDs have proved superior to those of other metal-free restorations. Clinical evaluations, which have been ongoing for 3 years, indicate a good success rate for zirconia FPDs. Zirconia implant abutments can also be used to improve the aesthetic outcome of implant-supported rehabilitations. Newly proposed zirconia implants seem to have good biological and mechanical properties; further studies are needed to validate their application.
Fan, Wei-Li; Sun, Hong-Zhen; Wu, Si-Yu; Wang, Ai-Min
2013-03-01
The most common treatment for old calcaneal fractures accompanied by subtalar joint injury is the use of subtalar in situ arthrodesis and subtalar distraction bone-block arthrodesis or osteotomy. This article describes the introduction of a novel surgical treatment, gradual subtalar distraction with external fixation and restoration of the calcaneal height, and presents an assessment of its efficacy. The protruding lateral calcaneus and the articular surfaces and subchondral bone of the posterior facet of the subtalar joint were surgically removed. An external fixator, attached with 2 pins in the subcutaneous tibia and 2 pins in the posterolateral calcaneus, was used to fix the subtalar joint for 7 to 10 days followed by gradual subtalar distraction at 1 mm/d. The lengthening procedure was stopped when the calcaneal height was restored according to radiography. The external fixator was removed after bone fusion. Seven cases of old calcaneal fractures accompanied by severe subtalar joint injury (8 feet) were treated using this method. Average follow-up was 14.3 months (range, 7-36 months). In all 7 cases (1 case of both feet), the postoperative wound healed primarily. The calcaneal heights of all 8 feet were partially restored. Subtalar joint bone fusion was completed within 4 to 6 months after the operation. The average preoperative American Orthopedic Foot & Ankle Society (AOFAS) hindfoot score was 25.3, and the average postoperative AOFAS score was 76.3. Subtalar distraction osteogenesis with external fixation was a novel and effective method for the treatment of old calcaneal fractures accompanied by severe subtalar joint injury in this small group of patients. Level IV, retrospective case series.
Heinemann, F; Mundt, T; Biffar, R; Gedrange, T; Goetz, W
2009-12-01
The aims of this case series was to evaluate the success rate of implants and their restorations, the sinus bone graft resorption, and the marginal bone loss around the implants when nanocristalline HA embedded in a silica matrix was exclusively used as grafting material. In 13 partially edentulous patients of a private practice having missing teeth in the posterior maxilla and a subantral bone height between 3 and 7 mm, 19 sinus augmentations (100% Nanobone, Artoss, Rostock, Germany) by the lateral lift technique were performed. The implants (Tiolox/Tiologic Implants, Dentaurum, Ispringen, Germany) were simultaneously placed. After 6 to 9 months 37 implants were restored with fixed dental prostheses. The clinical evaluation included peri-implant parameters, periotest measurements and the restorations. The radiographic bone heights over time were estimated with linear mixed models. The implant success rate was 100% after three years. The periotest values (between -7 and -6) after implant abutment connection indicated a solid osseointegration. The mean rates of the marginal bone loss over the first year were higher (mesial: -0.55, distal: -0.51 mm) than the annual rates thereafter (mesial: -0.09 mm, distal: -0.08 mm). The mean rates of changes in the total bone height were neglectable (<0.2 mm) and not significant. The prosthodontic and esthetic evaluation revealed a successful outcome. Within the limits of this clinical report it may be concluded that maxillary sinus augmentation using 100% nanocristalline HA embedded in a silica matrix to support implants is a reliable procedure.